WorldWideScience

Sample records for chromatography-electrospray tandem mass

  1. Liquid Chromatography-Electrospray Tandem Mass Spectrometry of Terpenoid Lactones in Ginkgo biloba

    OpenAIRE

    Sun, Yongkai; Li, Wenkui; Fitzloff, John F.; van Breemen, Richard B

    2005-01-01

    Ginkgo biloba (ginkgo) is one of most frequently used botanical dietary supplements. The bioactive constituents include the terpenoid lactones consisting of bilobalide and the ginkgolides A, B, C, and J. A new assay based on high performance liquid chromatography-electrospray tandem mass spectrometry (LC-MS-MS) was developed for the measurement of the terpenoid lactones in ginkgo products such as leaf powder and extracts. Initially, the MS-MS fragmentation pathways of ginkgolides were investi...

  2. Quantitative selenium speciation in human urine by using liquid chromatography-electrospray tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lu Ying [University of Crete, Department of Chemistry, Environmental Chemical Processes Laboratory, Voutes Campus, Heraklion 71003, Crete (Greece); Rumpler, Alice; Francesconi, Kevin A. [Institute of Chemistry-Analytical Chemistry, Karl-Franzens University Graz, Graz (Austria); Pergantis, Spiros A., E-mail: spergantis@chemistry.uoc.gr [University of Crete, Department of Chemistry, Environmental Chemical Processes Laboratory, Voutes Campus, Heraklion 71003, Crete (Greece)

    2012-06-20

    Highlights: Black-Right-Pointing-Pointer Development of a selected reaction monitoring mass spectrometric method for the identification of Se species in human urine. Black-Right-Pointing-Pointer A selenosugar was detected as the major human urinary metabolite of selenium in the samples analysed. Black-Right-Pointing-Pointer The trimethylselenonium ion was detected in the urine of one volunteer before and after receiving a selenium supplement. Black-Right-Pointing-Pointer Strict quality control measures were applied to validate identification. Black-Right-Pointing-Pointer Quantitation was conducted using an isotopically labelled internal standard and the standard additions methodology. - Abstract: A liquid chromatography-electrospray-tandem mass spectrometry (ES-MS/MS) method was developed for the speciation analysis of four organic selenium species of relevance to human urinary metabolism, namely trimethylselenomium ion (TMSe{sup +}), selenomethionine (SeMet) and the two selenosugars, methyl 2-acetamido-2-deoxy-1-seleno-{beta}-D-galactos/-glucos-amine (SeGalNAc and SeGluNAc, respectively). Their chromatographic separation was achieved by using a cation exchange pre-column coupled in-series with a reversed-phase high-performance liquid chromatography column, along with an isocratic mobile phase. Online detection was performed using ES-MS/MS in selective reaction monitoring mode. SeGalNAc was detected as the major human urinary metabolite of selenium in the samples analysed, whereas TMSe{sup +} was detected in the urine of one volunteer before and after receiving a selenium supplement. SeMet was not detected as a urine excretory metabolite in this study. Spiking experiments performed with the urine samples revealed significant signal suppression caused by coeluting matrix constituents. To overcome such interferences, isotopically labelled {sup 13}CD{sub 3}{sup 82}SeGalNAc was used as an internal standard, whereas in the absence of an isotopically labelled internal

  3. Specific determination of 20 primary aromatic amines in aqueous food simulants by liquid chromatography-electrospray ionization-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Mortensen, Sarah Kelly; Trier, Xenia Thorsager; Foverskov, Annie;

    2005-01-01

    A multi-analyte method without any pre-treatment steps using reversed-phase liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) was developed and applied for the determination of 20 primary aromatic amines (PAA) associated with polyurethane (PUR) products or azo...

  4. Characterisation of a proposed internet synthesis of N,N-dimethyltryptamine using liquid chromatography/electrospray ionisation tandem mass spectrometry.

    Science.gov (United States)

    Martins, Cláudia P B; Freeman, Sally; Alder, John F; Brandt, Simon D

    2009-08-14

    The psychoactive properties of N,N-dimethyltryptamine (DMT) are known to induce altered states of consciousness in humans. These properties attract great interest from clinical, neuroscientific, clandestine and forensic communities. The Breath of Hope Synthesis was reported on an internet website as a convenient two-step methodology for the preparation of DMT. The analytical characterisation of the first stage was the subject of previous publications by the authors and involved the thermal decarboxylation of tryptophan and the formation of tryptamine. The present study reports on the characterisation of the second step of this procedure which was based on the methylation of tryptamine. This employed methyl iodide and benzyltriethylammonium chloride/sodium hydroxide as a phase transfer catalyst. The reaction product was characterised by liquid chromatography/electrospray ionisation tandem mass spectrometry and orthogonal acceleration time-of-flight mass spectrometry. Quantitative evaluation was carried out in positive multiple reaction monitoring mode (MRM), which included synthesis of the identified reaction products. MRM screening of the product did not lead to the detection of DMT. Instead, 11.1% tryptamine starting material, 21.0% N,N,N-trimethyltryptammonium iodide (TMT) and 47.4% 1-N-methyl-TMT were detected. A 0.5% trace of the monomethylated N-methyltryptamine was also detected. This study demonstrated the impact on product purity of doubtful synthetic methodologies discussed on the internet. PMID:19592003

  5. Chemical Investigation of Saponins in Different Parts of Panax notoginseng by Pressurized Liquid Extraction and Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry

    OpenAIRE

    Si-Jia Hong; Peng Li; Yi-Tao Wang; Shao-Ping Li; Qing-Wen Zhang; Jian-Bo Wan

    2012-01-01

    A pressurized liquid extraction (PLE) and high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS) method was developed for the qualitative determination of saponins in different parts of P. notoginseng, including rhizome, root, fibre root, seed, stem, leaf and flower. The samples were extracted using PLE. The analysis was achieved on a Zorbax SB-C18 column with gradient elution of acetonitrile and 8 mM aqueous ammonium acet...

  6. Determination of benzotriazole corrosion inhibitors from aqueous environmental samples by liquid chromatography-electrospray ionization-tandem mass spectrometry.

    Science.gov (United States)

    Weiss, Stefan; Reemtsma, Thorsten

    2005-11-15

    The first method for the determination of commonly used corrosion inhibitors in environmental water samples by liquid chromatography-electrospray ionization-tandem mass spectrometry is presented. Benzotriazole (BTri) and the two isomers of tolyltriazole (5- and 4-TTri) are separated in an isocratic run. By gradient elution, BTri, 4-TTri, 5-TTri, and xylyltriazole can be determined simultaneously with three benzothiazoles, but here TTri isomers coelute. The instrumental detection limit of 2 pg allows the determination of the three most important benzotriazoles from municipal wastewater and most surface waters by direct injection into the HPLC system without previous enrichment. When solid-phase extraction is employed with mean recovery rates of 95-113%, the limit of quantification for benzotriazoles range from 10 ng/L in groundwater to 25 ng/L in untreated wastewater. BTri and TTri were determined in municipal wastewater in microgram per liter concentrations. Elimination in wastewater treatment appears to be poor, and BTri and TTri can be followed through a water cycle from treated municipal wastewater through surface water to bank filtrate used for drinking water production. The TTri isomers show markedly different biodegradation behavior with 4-TTri being more stable. PMID:16285694

  7. Trace analysis of quinolone and fluoroquinolone antibiotics from wastewaters by liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Xiao, Yang; Chang, Hong; Jia, Ai; Hu, Jianying

    2008-12-19

    A sensitive liquid chromatography-electrospray tandem mass spectrometry method, combined with solid-phase extraction and a weak cation exchange cartridge cleanup, was established for twenty quinolone and fluoroquinolone antibiotics (pipemidic acid, flerofloxacin, ofloxacin, pefloxacin, enoxacin, norfloxacin, ciprofloxacin, danofloxacin, enrofloxacin, lomefloxacin, difloxacin, sarafloxacin, gatifloxacin, sparfloxacin, moxifloxacin, cinoxacin, oxolinic acid, nalidixic acid, flumequine, and piromidic acid) in influent, effluent, and river waters. For the various water matrices considered, the overall recoveries were from 64% to 127% except for piromidic acid (27-33%), and no obvious matrix effect was observed. The method detection limits for the twenty target antibiotics in the influent, effluent, and surface water samples were 1.6-50 ng/L, 0.6-50 ng/L, and 0.8-50 ng/L, respectively. This method was applied to analyze residual quinolone and fluoroquinolone antibiotics in wastewater and surface water samples from Beijing, China. Eight antibiotics (12 (pipemidic acid)-1208 ng/L (ofloxacin)) were detected in wastewater, and seven (1.3 (lomefloxacin)-535 ng/L (ofloxacin)) were detected in surface water samples. Gatifloxacin, a 4th generation fluoroquinolone antibiotic, was detected for the first time in influent (111 ng/L), effluent (56 ng/L), and river water (16-42 ng/L). PMID:19007934

  8. Identification of forced degradation products of tamsulosin using liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Namdev, Deepak; Borkar, Roshan M; Raju, B; Kalariya, Pradipbhai D; Rahangdale, Vinodkumar T; Gananadhamu, S; Srinivas, R

    2014-01-01

    A rapid and gradient high-performance liquid chromatography combined with quadrupole time-of-flight electrospray ionization tandem mass spectrometry (LC/Q-TOF-ESI-MS/MS) method has been developed for the identification and structural characterization of stressed degradation products of tamsulosin. Tamsulosin, a selective α1-adrenoceptor antagonist, was subjected to forced degradation studies under hydrolytic (acid, base and neutral), oxidative, photolytic and thermal stress conditions as per ICH guidelines Q1A (R2). The drug degraded significantly under hydrolytic (base and neutral), thermal, oxidative and photolytic conditions, while it was stable to acid hydrolytic stress conditions. A total of twelve degradation products were formed and the chromatographic separation of the drug and its degradation products were achieved on a GRACE C-18 column (250mm×4.6mm, 5μm). All the degradants have been identified and characterized by LC/ESI-MS/MS and accurate mass measurements. To elucidate the structures of degradation products, fragmentation of the [M+H](+) ions of tamsulosin and its degradation products was studied by using LC-MS/MS experiments combined with accurate mass measurements. The product ions of all the protonated degradation products were compared with the product ions of protonated tamsulosin to assign most probable structures for the observed degradation products. PMID:24083958

  9. Ultra-high performance liquid chromatography-electrospray tandem mass spectrometry for the analysis of antibiotic residues in environmental waters.

    Science.gov (United States)

    Xue, Qiang; Qi, Yanjie; Liu, Fei

    2015-11-01

    An optimized solid-phase extraction (SPE) and ultra-high performance liquid chromatography-electrospray tandem mass spectrometry (UPLC-MS/MS) method was developed for the effective analysis of 35 antibiotics including sulfonamides (SAs), quinolones (QLs), tetracyclines (TCs), macrolides (MALs), lincomycin (LIN), and chloramphenicol (CAP). The addition of 0.1% formic acid to the mobile phase was favorable for the formation of [M + H](+) and the enhancement in the detection signals, but using ammonium formate decreased [M + H](+) with a corresponding reduction in the response of CAP. The optimal pH range for the SPE was 4.5 ∼ 5.0 with 6 mL aqueous ammonia/methanol (5/95, v/v) as the optimized eluent. An internal standard (IS) was selected for each type of analytes based on similarities in classification and retention time. The detection was completed in less than 10 min and was excellent with method detection limits (MDL) of 0.29 ∼ 4.03 ng/L. The recoveries of the antibiotics in samples from ultrapure water and groundwater were 67.13 ∼ 93.00% and 68.91 ∼ 92.67%, respectively. The antibiotics in samples collected from wastewater, surface water, and groundwater were also effectively detected. This newly developed method has the advantages of short detection times, small sample consumption, excellent reproducibility, and high sensitivity. This provides a reliable and promising technique for the simultaneous detection and monitoring of various residual antibiotics in aqueous environmental samples. PMID:26104902

  10. Development and comparison of two multiresidue methods for the analysis of 17 mycotoxins in cereals by liquid chromatography electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Desmarchelier, Aurelien; Oberson, Jean-Marie; Tella, Patricia; Gremaud, Eric; Seefelder, Walburga; Mottier, Pascal

    2010-07-14

    Two multiresidue methods based on different extraction procedures have been developed and compared for the liquid chromatography electrospray ionization tandem mass spectrometry analysis of 17 mycotoxins including ochratoxin A, aflatoxins (B(1), B(2), G(1), and G(2)), zearalenone, fumonisins (B(1) and B(2)), T-2 toxin, HT-2 toxin, nivalenol, deoxynivalenol, 3- and 15-acetyldeoxynivalenol, fusarenon-X, diacetoxyscirpenol, and neosolaniol in cereal-based commodities. The extraction procedures considered were a QuEChERS-like method and one using accelerated solvent extraction (ASE). Both extraction procedures gave similar performances in terms of linearity (r(2) > 0.98) and precision (both RSD(r) and RSD(iR) sample throughput as compared to the ASE method. PMID:20527950

  11. Characterization and identification of iridoid glucosides, flavonoids and anthraquinones in Hedyotis diffusa by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Liu, E-Hu; Zhou, Ting; Li, Guo-Bin; Li, Jing; Huang, Xiu-Ning; Pan, Feng; Gao, Ning

    2012-01-01

    The multiple bioactive constituents in Hedyotis diffusa Willd. (H. diffusa) were extracted and characterized by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC-ESI-MS(n)). The optimized separation condition was obtained using an Agilent ZorBax SB-C18 column (4.6×150 mm, 5 μm) and gradient elution with water (containing 0.1% formic acid) and acetonitrile (containing 0.1% formic acid), under which baseline separation for the majority of compounds was achieved. Among the compounds detected, 14 iridoid glucosides, 10 flavonoids, 7 anthraquinones, 1 coumarin and 1 triterpene were unambiguously identified or tentatively characterized based on their retention times and mass spectra in comparison with the data from standards or references. The fragmentation behavior for different types of constituents was also investigated, which could contribute to the elucidation of these constituents in H. diffusa. The present study reveals that even more iridoid glycosides were found in H. diffusa than hitherto assumed. The occurrence of two iridoid glucosides and five flavonoids in particular has not yet been described. This paper marks the first report on the structural characterization of chemical compounds in H. diffusa by a developed HPLC-ESI-MS(n) method. PMID:25940590

  12. Chemical Investigation of Saponins in Different Parts of Panax notoginseng by Pressurized Liquid Extraction and Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Si-Jia Hong

    2012-05-01

    Full Text Available A pressurized liquid extraction (PLE and high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS method was developed for the qualitative determination of saponins in different parts of P. notoginseng, including rhizome, root, fibre root, seed, stem, leaf and flower. The samples were extracted using PLE. The analysis was achieved on a Zorbax SB-C18 column with gradient elution of acetonitrile and 8 mM aqueous ammonium acetate as mobile phase. The mass spectrometer was operated in the negative ion mode using the electrospray ionization, and a collision induced dissociation (CID experiment was also carried out to aid the identification of compounds. Forty one saponins were identified in different parts of P. notoginseng according to the fragmentation patterns and literature reports, among them, 21 saponins were confirmed by comparing the retention time and ESI-MS data with those of standard compounds. The results showed that the chemical characteristics were obviously diverse in different parts of P. notoginseng, which is helpful for pharmacological evaluation and quality control of P. notoginseng.

  13. A simple and selective method for determination of phthalate biomarkers in vegetable samples by high pressure liquid chromatography-electrospray ionization-tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Xi; Cui, Kunyan; Zeng, Feng; Li, Shoucong; Zeng, Zunxiang

    2016-06-01

    In the present study, solid-phase extraction cartridges including silica reversed-phase Isolute C18, polymeric reversed-phase Oasis HLB and mixed-mode anion-exchange Oasis MAX, and liquid-liquid extractions with ethyl acetate, n-hexane, dichloromethane and its mixtures were compared for clean-up of phthalate monoesters from vegetable samples. Best recoveries and minimised matrix effects were achieved using ethyl acetate/n-hexane liquid-liquid extraction for these target compounds. A simple and selective method, based on sample preparation by ultrasonic extraction and liquid-liquid extraction clean-up, for the determination of phthalate monoesters in vegetable samples by liquid chromatography/electrospray ionisation-tandem mass spectrometry was developed. The method detection limits for phthalate monoesters ranged from 0.013 to 0.120ngg(-1). Good linearity (r(2)>0.991) between MQLs and 1000× MQLs was achieved. The intra- and inter-day relative standard deviation values were less than 11.8%. The method was successfully used to determine phthalate monoester metabolites in the vegetable samples. PMID:26830597

  14. Investigation of natural phosphatidylcholine sources: separation and identification by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS2) of molecular species.

    Science.gov (United States)

    Le Grandois, Julie; Marchioni, Eric; Zhao, Minjie; Giuffrida, Francesca; Ennahar, Saïd; Bindler, Françoise

    2009-07-22

    This study is a contribution to the exploration of natural phospholipid (PL) sources rich in long-chain polyunsaturated fatty acids (LC-PUFAs) with nutritional interest. Phosphatidylcholines (PCs) were purified from total lipid extracts of different food matrices, and their molecular species were separated and identified by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS(2)). Fragmentation of lithiated adducts allowed for the identification of fatty acids linked to the glycerol backbone. Soy PC was particularly rich in species containing essential fatty acids, such as (18:2-18:2)PC (34.0%), (16:0-18:2)PC (20.8%), and (18:1-18:2)PC (16.3%). PC from animal sources (ox liver and egg yolk) contained major molecular species, such as (16:0-18:2)PC, (16:0-18:1)PC, (18:0-18:2)PC, or (18:0-18:1)PC. Finally, marine source (krill oil), which was particularly rich in (16:0-20:5)PC and (16:0-22:6)PC, appeared to be an interesting potential source for food supplementation with LC-PUFA-PLs, particularly eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA). PMID:19545117

  15. Determination of selected antibiotics in the Victoria Harbour and the Pearl River, South China using high-performance liquid chromatography-electrospray ionization tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Xu Weihai [State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou, Guangzhou 510640 (China); School of Chemistry and Chemical Engineering, Zhongshan University, Guangzhou 510250 (China); Department of Civil and Structural Engineering, Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China); Post-graduate School of the Chinese Academy of Sciences, Beijing 100039 (China); Zhang Gan [State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou, Guangzhou 510640 (China)]. E-mail: zhanggan@gig.ac.cn; Zou Shichun [School of Chemistry and Chemical Engineering, Zhongshan University, Guangzhou 510250 (China); Li Xiangdong [Department of Civil and Structural Engineering, Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China); Liu Yuchun [School of Chemistry and Chemical Engineering, Zhongshan University, Guangzhou 510250 (China)

    2007-02-15

    Nine selected antibiotics in the Victoria Harbour of Hong Kong and the Pearl River at Guangzhou, South China, were analyzed using high-performance liquid chromatography-electrospray ionization tandem mass spectrometry. The results showed that the concentrations of antibiotics were mainly below the limit of quantification (LOQ) in the marine water of Victoria Harbour. However, except for amoxicillin, all of the antibiotics were detected in the Pearl River during high and low water seasons with the median concentrations ranging from 11 to 67 ng/L, and from 66 to 460 ng/L, respectively; and the concentrations in early spring were about 2-15 times higher than that in summer with clearer diurnal variations. It was suggested that the concentrations of antibiotics in the high water season were more affected by wastewater production cycles due to quick refreshing rate, while those in the low water season may be more sensitive to the water column dynamics controlled by tidal processes in the river. - Antibiotics were found at high concentrations in an urban reach of Pearl River in southern China with contrast diurnal variations between the high and low water seasons.

  16. Determination of selected antibiotics in the Victoria Harbour and the Pearl River, South China using high-performance liquid chromatography-electrospray ionization tandem mass spectrometry

    International Nuclear Information System (INIS)

    Nine selected antibiotics in the Victoria Harbour of Hong Kong and the Pearl River at Guangzhou, South China, were analyzed using high-performance liquid chromatography-electrospray ionization tandem mass spectrometry. The results showed that the concentrations of antibiotics were mainly below the limit of quantification (LOQ) in the marine water of Victoria Harbour. However, except for amoxicillin, all of the antibiotics were detected in the Pearl River during high and low water seasons with the median concentrations ranging from 11 to 67 ng/L, and from 66 to 460 ng/L, respectively; and the concentrations in early spring were about 2-15 times higher than that in summer with clearer diurnal variations. It was suggested that the concentrations of antibiotics in the high water season were more affected by wastewater production cycles due to quick refreshing rate, while those in the low water season may be more sensitive to the water column dynamics controlled by tidal processes in the river. - Antibiotics were found at high concentrations in an urban reach of Pearl River in southern China with contrast diurnal variations between the high and low water seasons

  17. Analysis by liquid chromatography-electrospray ionization tandem mass spectrometry and acute toxicity evaluation for beta-blockers and lipid-regulating agents in wastewater samples.

    Science.gov (United States)

    Hernando, M D; Petrovic, M; Fernández-Alba, A R; Barceló, D

    2004-08-13

    This paper describes a multiresidue method for the extraction and determination of two therapeutic groups of pharmaceuticals, lipid-regulating agents (clofibric acid, bezafibrate, gemfibrocil, fenofibrate) and beta-blockers (atenolol, sotalol, metoprolol, betaxolol) in waters by solid-phase extraction followed by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS). Recoveries obtained from spiked HPLC water, as well as, from spiked real samples (sewage treatment plants influent and effluents, river and tap water) were all above 60%, with the exception of betaxolol with a 52% recovery. The quantitative MS analysis was performed using a multiple reaction monitoring. The LC-MS-MS method gave detection limits ranging from 0.017 to 1.25 microg/l in spiked effluent. Precision of the method, calculated as relative standard deviation, ranged from 3.7 to 18.5%. Individual and combined effects on Daphnia magna were evaluated for both therapeutic groups. Individual effects in culture medium showed these compounds as not harmful and not toxic, an exception is fenofibrate that was found to be harmful, but at high, in the environment unrealistic concentrations (EC50 of 50 mg/l). Combined effect in wastewater showed synergistic toxic effects at low concentration level (2 microg/l). PMID:15387181

  18. Liquid Chromatography-electrospray Ionization Tandem Mass Spectrometry for Simultaneous Determination of Metformin and Glimepiride in Beagle Dog Plasma and Bioequivalence Study

    Institute of Scientific and Technical Information of China (English)

    BAI Jing; SHI Xiao-wei; DU Ying-feng; XIANG Bai; WANG Shuai; CAO De-ying

    2012-01-01

    A sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry(LC-ESI-MS/MS) was used for the simultaneous determination of metformin and glimepiride in beagle dog plasma with glipizide as internal standard(IS).After simplified protein precipitation with methanol,both the analytes and IS were chromatographed on a Zorbax CN column via gradient elution with methanol(containing 5 mmol/L ammonium acetate) and 5 mmol/L aqueous ammonium acetate as the mobile phase.Detection was performed by multiple reaction monitoring(MRM) scanning via ESI source operated in positive ionization mode.Specificity,linearity,accuracy,precision,recovery,matrix effect and stability were validated for metformin and glimepiride in beagle dog plasma.The calibration curves were linear in a concentration range of 10--10000 ng/mL for metformin and 4--4000 ng/mL for glimepiride with both correlation coefficients higher than 0.99.The recoveries obtained for the analytes and IS were all between 82.7% and 101.2%.The method exhibited excellent performance in terms of selectivity,robustness,short analytical time and simplicity of sample preparation.Finally,the proposed method was applied to a bioequivalence study of self-made bilayer tablet and commercial formulation containing 500 mg of metformin and 1 mg of glimepiride in beagle dogs.

  19. Simultaneous determination of 13 quinolones in eggs using column high-performance liquid chromatography/electrospray ionization-tandem mass spectrometry and depletion of pefloxacin methanesulfonate in eggs.

    Science.gov (United States)

    Shen, Jianzhong; Li, Haiyan; Jiang, Haiyang; Zhou, Degang; Xu, Fei; Li, Jiancheng; Ding, Shuangyang

    2008-01-01

    An efficient method was developed for simultaneous determination of 13 quinolones--namely, enoaxacin (ENO), marbofloxacin (MAR), ciprofloxacin (CIP), norfloxacin (NOR), ofloxacin (OFL), pefloxacin methanesulfonate (PEF), danofloxacin (DAN), enrofloxacin (ENR), lomefloxacin (LOM), difloxacin (DIF), sarafloxacin (SAR), oxolinic acid (OXO), and flumequine (FLU)--in eggs by column liquid chromatography/electrospray ionization-tandem mass spectrometry. Samples were extracted with a phosphoric acid-phosphate buffer followed by purification with a solid-phase extraction cartridge. Recoveries for the 13 quinolones were 67-93% with intraday and interday coefficients of variation ranging from 4 to 9% and 2 to 18%, respectively. The limit of determination was 0.05 microg/kg for OXO and FLU; 0.1 microg/kg for MAR, OFL, CIP, LOM, DAN, SAR, DIF, NOR, and ENR; and 0.2 microg/kg for ENO and PEF. The method was also applied to study the depletion of PEF in eggs. The concentration of PEF increased and reached a maximum value on the third day, and then decreased rapidly until it could not be detected on day 32; its metabolite NOR was detectable on the second day, and then reached a maximum on the sixth day, after which it could not be detected until day 15. PMID:19202815

  20. Simultaneous Determination of Eight Ginsenosides in Rat Plasma by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry: Application to Their Pharmacokinetics.

    Science.gov (United States)

    Ma, Li-Yuan; Zhang, You-Bo; Zhou, Qi-Le; Yang, Yan-Fang; Yang, Xiu-Wei

    2015-01-01

    A high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method was successfully developed and validated for the identification and determination of eight ginsenosides: ginsenoside Rg₁ (1); 20(S)-ginsenoside Rh₁ (2); 20(S)-ginsenoside Rg₂ (3); 20(R)-ginsenoside Rh₁ (4); 20(R)-ginsenoside Rg₂ (5); ginsenoside Rd (6); 20(S)-ginsenoside Rg₃ (7); and 20(R)-ginsenoside Rg₃ (8) in rat plasma. The established rapid method had high linearity, selectivity, sensitivity, accuracy, and precision. The method has been used successfully to study the pharmacokinetics of abovementioned eight ginsenosides for the first time. After an oral administration of total saponins in the stems-leaves of Panax ginseng C. A. Meyer (GTSSL) at a dose of 400 mg/kg, the ginsenosides 6, 7, and 8, belonging to protopanaxadiol-type saponins, exhibited relatively long tmax values, suggesting that they were slowly absorbed, while the ginsenosides 1-5, belonging to protopanaxatriol-type saponins, had different tmax values, which should be due to their differences in the substituted groups. Compounds 2 and 4, 3 and 5, 7 and 8 were three pairs of R/S epimerics at C-20, which was interesting that the t1/2 of 20(S)-epimers were always longer than those of 20(R)-epimers. This pharmacokinetic identification of multiple ginsenosides of GTSSL in rat plasma provides a significant basis for better understanding the clinical application of GTSSL. PMID:26633350

  1. High-internal-phase-emulsion polymeric monolith coupled with liquid chromatography-electrospray tandem mass spectrometry for enrichment and sensitive detection of trace cytokinins in plant samples.

    Science.gov (United States)

    Du, Fuyou; Sun, Lin; Zhen, Xian; Nie, Honggang; Zheng, Yanjie; Ruan, Guihua; Li, Jianping

    2015-08-01

    High-internal-phase-emulsion polymers (polyHIPEs) show great promise as solid-phase-extraction (SPE) materials because of the tremendous porosity and highly interconnected framework afforded by the high-internal-phase-emulsion (HIPE) technique. In this work, polyHIPE monolithic columns as novel SPE materials were prepared and applied to trace enrichment of cytokinins (CKs) from complex plant samples. The polyHIPE monoliths were synthesized via the in-situ polymerization of the continuous phase of a HIPE containing styrene (STY) and divinylbenzene (DVB) in a stainless column, and revealed highly efficient and selective enrichment ability for aromatic compounds. Under the optimized experimental conditions, a method using a monolithic polyHIPE column combined with liquid chromatography-electrospray tandem mass spectrometry (LC-MS-MS) was developed for the simultaneous extraction and sensitive determination of trans-zeatin (tZ), meta-topolin (mT), kinetin (K), and kinetin riboside (KR). The proposed method had good linearity, with correlation coefficients (R (2)) from 0.9957 to 0.9984, and low detection limits (LODs, S/N = 3) in the range 2.4-47 pg mL(-1) for the four CKs. The method was successfully applied to the determination of CKs in real plant samples, and obtained good recoveries ranging from 68.8 % to 103.0 % and relative standard deviations (RSDs) lower than 16 %. PMID:26025552

  2. Identification of glycerophospholipid molecular species of mussel (Mytilus edulis) lipids by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry.

    Science.gov (United States)

    Yin, Fa-Wen; Zhou, Da-Yong; Zhao, Qi; Liu, Zhong-Yuan; Hu, Xiao-Pei; Liu, Yan-Fei; Song, Liang; Zhou, Xin; Qin, Lei; Zhu, Bei-Wei; Shahidi, Fereidoon

    2016-12-15

    This study was carried out to identify the glycerophosphocholine (GPCho), glycerophosphoethanolamine (GPEtn) and glycerophosphoserine (GPSer) compositions in lipids extracted from mussels using Folch, Bligh-Dyer and methyl-tert-butyl ether (MTBE) methods by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS). The molecular species of GPCho, GPEtn and GPSer were characterized according to the MS and MS/MS information. A semi-quantitative method using internal standard was established to compare the difference in glycerophospholipids (GP) between samples recovered with different methods. At least 212, 230 and 206 GP species were identified, respectively, from lipids recovered by Folch, Bligh-Dyer and MTBE methods. Most of the abundant GP species in mussels contained EPA and DHA. Some GP species with low content were not present in lipids recovered by the Folch and MTBE methods when compared with that recovered by the Bligh-Dyer method. However, for most GP species in lipids recovered by different methods, no quantitative differences existed. PMID:27451190

  3. Characterization of Proanthocyanidins from Parkia biglobosa (Jacq. G. Don. (Fabaceae by Flow Injection Analysis — Electrospray Ionization Ion Trap Tandem Mass Spectrometry and Liquid Chromatography/Electrospray Ionization Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Wagner Vilegas

    2013-03-01

    Full Text Available The present study investigates the chemical composition of the African plant Parkia biglobosa (Fabaceae roots and barks by Liquid Chromatography - Electrospray Ionization and Direct Injection Tandem Mass Spectrometry analysis. Mass spectral data indicated that B-type oligomers are present, namely procyanidins and prodelphinidins, with their gallate and glucuronide derivatives, some of them in different isomeric forms. The analysis evidenced the presence of up to 40 proanthocyanidins, some of which are reported for the first time. In this study, the antiradical activity of extracts of roots and barks from Parkia biglobosa was evaluated using DPPH method and they showed satisfactory activities.

  4. Determination of chlorinated acid herbicides in vegetation and soil by liquid chromatography/electrospray-tandem mass spectrometry.

    Science.gov (United States)

    Schaner, Angela; Konecny, Jaclyn; Luckey, Laura; Hickes, Heidi

    2007-01-01

    The method presented uses reversed-phase liquid chromatography with negative electrospray ionization and tandem mass spectrometry to analyze 9 chlorinated acid herbicides in soil and vegetation matrixes: clopyralid, dicamba, MCPP, MCPA, 2,4-DP, 2,4-D, triclopyr, 2,4-DB, and picloram. A 20 g portion is extracted with a basic solution and an aliquot acidified and micropartitioned with 3 mL chloroform. Vegetation samples are subjected to an additional cleanup with a mixed-mode anion exchange solid-phase extraction cartridge. Two precursor product ion transitions per analyte are measured and evaluated to provide the maximum degree of confidence in results. Average recoveries for 3 different soil types tested ranged from 72 to 107% for all compounds with the exception of 2,4-DB at 56-99%. Average recoveries for the 3 different vegetation types studied were lower and ranged from 53 to 80% for all compounds. PMID:17955986

  5. Quantification of γ-Aminobutyric Acid in Cerebrospinal Fluid Using Liquid Chromatography-Electrospray Tandem Mass Spectrometry.

    Science.gov (United States)

    Arning, Erland; Bottiglieri, Teodoro

    2016-01-01

    We describe a simple stable isotope dilution method for accurate and precise measurement of γ-aminobutyric acid (GABA), a major inhibitory neurotransmitter in human cerebrospinal fluid (CSF) as a clinical diagnostic test. Determination of GABA in CSF (50 μL) was performed utilizing high performance liquid chromatography coupled with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Analysis of free and total GABA requires two individual sample preparations and mass spectrometry analyses. Free GABA in CSF is determined by a 1:2 dilution with internal standard (GABA-D2) and injected directly onto the HPLC-ESI-MS/MS system. Determination of total GABA in CSF requires additional sample preparation in order to hydrolyze all the bound GABA in the sample to the free form. This requires hydrolyzing the sample by boiling in acidic conditions (hydrochloric acid) for 4 h. The sample is then further diluted 1:10 with a 90 % acetonitrile/0.1 % formic acid solution and injected into the HPLC-ESI-MS/MS system. Each assay is quantified using a five-point standard curve and is linear from 6 nM to 1000 nM and 0.63 μM to 80 μM for free and total GABA, respectively. PMID:26602123

  6. Identification and quantification of salinomycin in intoxicated human plasma by liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Li, Yu; Fang, Junjian; Wu, Shengming; Ma, Kunpeng; Li, Haijing; Yan, Xianzhong; Dong, Fangting

    2010-09-01

    Salinomycin is a polyether ionophore antibiotic that is widely used in poultry and livestock. Exposure of humans to salinomycin via inhalation or ingestion can cause severe toxicity. The aim of the present work was to develop a simple and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the rapid identification and quantification of salinomycin in human plasma. After removing protein using methanol, plasma samples were eluted from a Waters Xterra(®) MS C18 column with an isocratic mobile phase. Detection and quantification of the drug were performed with a triple-quadruple mass spectrometer by monitoring for two specific transitions in the electrospray, positive-ion, multiple-reaction monitoring mode. Assay validation showed good linearity (r(2) = 0.998). The detection and quantification limits of the method were 0.6 and 16 pg/mL, respectively. The inter- and intraday coefficients of variation for the assay were both intoxicated patients were analyzed using this method. Salinomycin was detected in six samples, at concentrations of between 0.6 and 46.5 pg/mL. The described assay method allows the sensitive and rapid identification and quantification of salinomycin in human plasma, and thus provides a valuable tool for the specific diagnosis of salinomycin intoxication in clinical and emergency rescue practice. PMID:20652685

  7. Simultaneous quantitation of atorvastatin and its two active metabolites in human plasma by liquid chromatography/(-) electrospray tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Pankaj Partani; S. Manaswita Verma; Sanjay Gurule; Arshad Khuroo; Tausif Monif

    2014-01-01

    A sensitive, accurate and selective liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed and validated for the simultaneous quantitation of atorvastatin (AT) and its equipotent hydroxyl metabolites, 2-hydroxy atorvastatin (2-AT) and 4-hydroxy atorvastatin (4-AT), in human plasma. Electrospray ionization (ESI) interface in negative ion mode was selected to improve the selectivity and the sensitivity required for this application. Additionally, a solid phase extraction (SPE) step was performed to reduce any ion-suppression and/or enhancement effects. The separation of all compounds was achieved in less than 6 min using a C18 reverse-phase fused-cores column and a mobile phase, composed of a mixture of 0.005%formic acid in water:acetonitrile:methanol (35:25:40, v/v/v), in isocratic mode at a flow rate of 0.6 mL/min. The method has lower limit of quantitation (LLOQ) of 0.050 ng/mL for all analytes. The method has shown tremendous reproducibility, with intra-and inter-day precision less than 6.6%, and intra- and inter-day accuracy within 74.3% of nominal values, for all analytes, and has proved to be highly reliable for the analysis of clinical samples.

  8. Determination of 16 insect growth regulators in edible Chinese traditional herbs by liquid chromatography electrospray tandem mass spectrometry.

    Science.gov (United States)

    Qian, Mingrong; Wu, Liqin; Zhang, Hu; Xu, Mingfei; Li, Rui; Wang, Xiangyun; Sun, Caixia

    2012-03-01

    A new sensitive multiresidue liquid chromatography-tandem mass spectrometry (LC-MS/MS) analytical method for the determination of 16 insect growth regulator (IGR) residues-RH-5849 (1,2-dibenzoyl-1-tert-butylhydrazine), halofenozide, methoxyfenozide, chromafenozide, fufenozide, tebufenozide, diflubenzuron, chlorbenzuron, triflumuron, hexaflumuron, novaluron, lufenuron, teflubenzuron, flucycloxuron, flufenoxuron, and chlorfluazuron-in herbs (Perilla frutescens, flos chrysanthemi, lily bulbs, and ginger) has been developed. After the herbs had been extracted with acetonitrile, a combined graphitized nonporous carbon/aminopropyl (ENVI-Carb/LC-NH(2)) cartridge and a Florisil cartridge were used to clean up the extracts. LC-MS/MS was performed in multiple reaction monitoring mode with two specific precursor ion-product ion transitions per IGR to confirm and quantitate the residues in herbs. Quantitation was performed on the basis of matrix-matched calibrations. The method showed excellent linearity (r(2) > 0.99) and precision (relative standard deviations of 13.6 or lower) for all the target insecticides. The limits of quantitation were 0.6-10 μg kg(-1) for the 16 insecticides in the four herbs. The average recoveries, measured at three concentrations (0.01, 0.1, 1 mg kg(-1)), were in the range 74.8-105.3%. The method was satisfactorily applied for the analysis of 60 herb samples (Perilla frutescens, flos chrysanthemi, lily bulbs, and ginger). Hexaflumuron was detected at concentrations of 0.029 and 0.051 mg kg(-1) in Perilla frutescens. PMID:22271101

  9. Differential Isotope Labeling of 38 Dietary Polyphenols and Their Quantification in Urine by Liquid Chromatography Electrospray Ionization Tandem Mass Spectrometry.

    Science.gov (United States)

    Achaintre, David; Buleté, Audrey; Cren-Olivé, Cécile; Li, Liang; Rinaldi, Sabina; Scalbert, Augustin

    2016-03-01

    A large number of polyphenols are consumed with the diet and may contribute to the prevention of chronic diseases such as cardiovascular diseases, diabetes, cancers, and neurodegenerative diseases. More comprehensive methods are needed to measure exposure to this complex family of bioactive plant compounds in epidemiological studies. We report here a novel method enabling the simultaneous measurement in urine of 38 polyphenols representative of the main classes and subclasses found in the diet. This method is based on differential (12)C-/(13)C-isotope labeling of polyphenols through derivatization with isotopic dansyl chloride reagents and on the analysis of the labeled polyphenols by tandem mass spectrometry. This derivatization approach overcomes the need for costly labeled standards. Different conditions for enzyme hydrolysis of polyphenol glucuronides and sulfate esters, extraction, and dansylation of unconjugated aglycones were tested and optimized. Limits of quantification varied from 0.01 to 1.1 μM depending on polyphenols. Intrabatch coefficients of variation varied between 3.9% and 9.6%. Interbatch variations were lower than 15% for 31 compounds and lower than 29% for 6 additional polyphenols out of the 38 tested. Thirty seven polyphenols were validated and then analyzed in 475, 24 h urine samples from the European Prospective Investigation on Cancer and Nutrition (EPIC) study. Thirty four polyphenols could be detected and successfully estimated and showed large interindividual variations of concentrations (2-3 orders of magnitude depending on the compound), with median concentrations spanning from 0.01 to over 1000 μM for all 34 compounds. PMID:26814424

  10. Quantitation of S-Adenosylmethionine and S-Adenosylhomocysteine in Plasma Using Liquid Chromatography-Electrospray Tandem Mass Spectrometry.

    Science.gov (United States)

    Arning, Erland; Bottiglieri, Teodoro

    2016-01-01

    We describe a simple stable isotope dilution method for accurate determination of S-adenosylmethionine (SAM) and S-adenosylhomocysteine (SAH) in plasma as a diagnostic test. SAM and SAH are key metabolic intermediates of methionine metabolism and the methylation cycle. Determination of SAM and SAH in plasma was performed by high performance liquid chromatography coupled with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Calibrators (SAM and SAH) and internal standards ((2)H3-SAM and (2)H4-SAH) were included in each analytical run for calibration. Sample preparation involved combining 20 μL sample with 180 μL of internal standard solution consisting of heavy isotope labeled internal standards in mobile phase A and filtering by ultracentrifugation through a 10 kd MW cutoff membrane. Sample filtrate (3 μL) was injected by a Shimadzu Nexera LC System interfaced with a 5500 QTRAP(®) (AB Sciex). Chromatographic separation was achieved on a 250 mm × 2.0 mm EA:faast column from Phenomenex. Samples were eluted at a flow rate of 0.20 mL/min with a binary gradient with a total run time of 10 min. The source operated in positive ion mode at an ion spray voltage of +5000 V. SAM and SAH resolved by a gradient to 100 % methanol with retention times of 6.0 and 5.7 min, respectively. The observed m/z values of the fragment ions were m/z 399 → 250 for SAM, m/z 385 → 136 for SAH, m/z 402 → 250 for (2)H3-SAM, m/z 203 → 46. The calibration curve was linear over the ranges of 12.5-5000 nmol/L for SAM and SAH. PMID:26602137

  11. Analysis of organophosphate flame retardant diester metabolites in human urine by liquid chromatography electrospray ionisation tandem mass spectrometry.

    Science.gov (United States)

    Van den Eede, Nele; Neels, Hugo; Jorens, Philippe G; Covaci, Adrian

    2013-08-16

    A new analytical method was developed for the determination of dialkyl and diaryl phosphates (DAPs), which are metabolites of organophosphate triesters (PFRs), in human urine. Target DAPs included dibutyl phosphate (DBP), diphenyl phosphate (DPHP), bis(2-butoxyethyl) phosphate (BBOEP), bis(2-chloroethyl) phosphate (BCEP), bis(1-chloro-2-propyl) phosphate (BCPP), and bis(1,3-dichloro-2-propyl) phosphate (BDCIPP). Sample preparation was based on solid phase extraction using a weak anion exchange sorbent (Oasis WAX). Although several instrumental techniques have been tested, best results were obtained with reversed phase liquid chromatography-negative electrospray ionisation tandem mass spectrometry (LC-ESI-MS/MS) taking the total analysis time into account. Method accuracy at 3ng/mL in pooled urine ranged between 69 and 119% (recovery), while inter-day imprecision (as relative standard deviation) was sensitivity for BCEP, BCIPP, and BDCIPP, their respective mLOQs being 0.1, 0.06, 0.02ng/mL, compared to 1.2, 3.7, and 0.5ng/mL by LC-MS/MS. A set of urine samples from volunteers was analysed, in which DPHP was the major DAP metabolite. A significant increase of DPHP levels was observed in the group of smokers (geometric mean of 1.55ng/mL) compared to the non-smokers (geometric mean of 0.88ng/mL). Metabolic transformation of triphenyl phosphate to DPHP by metabolic enzymes induced in smokers could be an explanation for this observation. PMID:23849782

  12. Liquid chromatography-electrospray ionization-tandem mass spectrometry for simultaneous analysis of chlorogenic acids and their metabolites in human plasma.

    Science.gov (United States)

    Matsui, Yuji; Nakamura, Shun; Kondou, Naoki; Takasu, Yoshio; Ochiai, Ryuji; Masukawa, Yoshinori

    2007-10-15

    A method using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) was developed for the simultaneous analysis of nine chlorogenic acids (CGAs), three isomers each of caffeoylquinic acids (CQAs), feruloylquinic acids (FQAs) and dicaffeoylquinic acids (dCQAs), and their two metabolites, caffeic acid (CA) and ferulic acid (FA), in human plasma. In simultaneous multiple reaction monitoring (MRM) measurements using ESI-MS/MS with a negative ion mode, a deprotonated molecular ion derived from each of the 11 molecules was used as a precursor ion while three diagnostic product ions characteristic for each were selected for the qualitative analysis. To obtain maximal intensities for all diagnostic product ions, the collision energy was optimized for each one. LC separation was achieved under conditions of a reversed-phase Inertsil ODS-2 column combined with a gradient elution system using 50mM acetic acid with 3% acetonitrile aqueous solution and 50 mM acetic acid with 100% acetonitrile. In the quantitative analysis, one of the three diagnostic product ions for each of the 11 molecules was selected. Application of simultaneous LC-ESI-MS/MS MRM measurements to analyze the 11 standards spiked into blank human plasma indicated that all diagnostic product ions were detected without any interference, and that the sensitivity, linearity and recovery of this method were acceptable. When using this method to analyze those 11 molecules in the plasma after oral ingestion of 250 ml of a drink containing a green coffee bean extract (300 mg CGAs), all 11 molecules were identified and CQAs, FQAs and FA were quantified. CQAs, FQAs and dCQAs in human plasma were detected for the first time. This method should be useful to understand the biological and pharmacological effects of CGAs, such as improvement of human hypertension. PMID:17766198

  13. Fully automated analysis of beta-lactams in bovine milk by online solid phase extraction-liquid chromatography-electrospray-tandem mass spectrometry.

    Science.gov (United States)

    Kantiani, Lina; Farré, Marinella; Sibum, Martin; Postigo, Cristina; López de Alda, Miren; Barceló, Damiá

    2009-06-01

    A fully automated method for the detection of beta-lactam antibiotics, including six penicillins (amoxicillin, ampicillin, cloxacillin, dicloxacillin, oxacillin, and penicillin G) and four cephalosporins (cefazolin, ceftiofur, cefoperazone, and cefalexin) in bovine milk samples has been developed. The outlined method is based on online solid-phase extraction-liquid chromatography/electrospray-tandem mass spectrometry (SPE-LC/ESI-MS-MS). Target compounds were concentrated from 500 microL of centrifuged milk samples using an online SPE procedure with C18 HD cartridges. Target analytes were eluted with a gradient mobile phase (water + 0.1% formic acid/methanol + 0.1% formic acid) at a flow rate of 0.7 mL/min. Chromatographic separation was achieved within 10 min using a C-12 reversed phase analytical column. For unequivocal identification and confirmation, two multiple reaction monitoring (MRM) transitions were acquired for each analyte in the positive electrospray ionization mode (ESI(+)). Method limits of detection (LODs) in milk were well below the maximum residue limits (MRLs) set by the European Union for all compounds. Limits of quantification in milk were between 0.09 ng/mL and 1.44 ng/mL. The developed method was validated according to EU's requirements, and accuracy results ranged from 80 to 116%. Finally, the method was applied to the analysis of twenty real samples previously screened by the inhibition of microbial growth test Eclipse 100. This new developed method offers high sensitivity and accuracy of results, minimum sample pre-treatment, and uses for the first time an automated online SPE offering a high throughput analysis. Because of all these characteristics, the proposed method is applicable and could be deemed necessary within the field of food control and safety. PMID:19402673

  14. Study on oligosaccharide composition of wort and beer samples by liquid chromatography/electrospray ionization tandem mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Čmelík, Richard; Berkecz, R.; Janáky, T.; Bobálová, Janette

    Olomouc : Faculty of Science, Palacký University Olomouc, 2010 - (Maier, V.), s. 56-57 ISBN 978-80-244-2470-5. - (CHEMICA 47S). [Advances in Chromatography and Electrophoresis & Chiranal 2010. Olomouc (CZ), 08.02.2010-11.02.2010] R&D Projects: GA MŠk 2B06037; GA MŠk MEB040807 Institutional research plan: CEZ:AV0Z40310501 Keywords : HPLC * mass spectrometry * brewing Subject RIV: CB - Analytical Chemistry, Separation

  15. Letter: characterisation and identification of spermine and spermidine derivatives in Microdesmis keayana and Microdesmis puberula roots by electrospray ionisation tandem mass spectrometry and high-performance liquid chromatography/electrospray ionisation tandem mass spectrometry.

    Science.gov (United States)

    Roumy, Vincent; Hennebelle, Thierry; Zamblé, Alexis; Zamblé Yao, Jacques; Sahpaz, Sevser; Bailleul, François

    2008-01-01

    Three new N(1),N(5),N(14)-tris(4- hydroxycinnamoyl)spermines were identified in hydromethanolic root extracts of Microdesmis keayana J. Léonard and Microdesmis puberula Hook f. The electrospray ionisation tandem mass spectrometry (ESI-MS/MS) technique with specific nuclear magnetic resonance analysis of hydrolysed products made it possible to identify N(1),N(5),N(14)-tris(p-coumaroyl)spermine, N(1)-feruloyl,N(5),N(14)-di(p-coumaroyl)spermine and N(1),N(5),N(14)-tris(feruloyl)spermine, named keayanines B, C and D, respectively. ESI-MS/MS analysis most effectively provided structural data although high-performance liquid chromatography/electrospray ionisation tandem mass spectrometry was also used to characterise four other compounds from Microdesmis puberula-keayanidines A, B, C and keayanine A-which had already been identified in M. keayana. This chemical data is the first to be published for M. puberula which is a commonly used plant in Central African traditional medicine. PMID:18493101

  16. Characterisation of cholera toxin by liquid chromatography - Electrospray mass spectrometry

    NARCIS (Netherlands)

    Baar, B.L.M. van; Hulst, A.G.; Wils, E.R.J.

    1999-01-01

    Cholera toxin, one of the toxins that may be generated by various strains of the bacterium Vibrio cholerae, can be considered as a substance possibly used in biological warfare. The possibilities of characterising the toxin by liquid chromatography electrospray mass spectrometry (LC-ES-MS) were inve

  17. Diclofenac in municipal wastewater treatment plant: quantification using laser diode thermal desorption--atmospheric pressure chemical ionization--tandem mass spectrometry approach in comparison with an established liquid chromatography-electrospray ionization-tandem mass spectrometry method.

    Science.gov (United States)

    Lonappan, Linson; Pulicharla, Rama; Rouissi, Tarek; Brar, Satinder K; Verma, Mausam; Surampalli, Rao Y; Valero, José R

    2016-02-12

    Diclofenac (DCF), a prevalent non-steroidal anti-inflammatory drug (NSAID) is often detected in wastewater and surface water. Analysis of the pharmaceuticals in complex matrices is often laden with challenges. In this study a reliable, rapid and sensitive method based on laser diode thermal desorption/atmospheric pressure chemical ionization (LDTD/APCI) coupled with tandem mass spectrometry (MS/MS) has been developed for the quantification of DCF in wastewater and wastewater sludge. An established conventional LC-ESI-MS/MS (liquid chromatography-electrospray ionization-tandem mass spectrometry) method was compared with LDTD-APCI-MS/MS approach. The newly developed LDTD-APCI-MS/MS method reduced the analysis time to 12s in lieu of 12 min for LC-ESI-MS/MS method. The method detection limits for LDTD-APCI-MS/MS method were found to be 270 ng L(-1) (LOD) and 1000 ng L(-1) (LOQ). Furthermore, two extraction procedures, ultrasonic assisted extraction (USE) and accelerated solvent extraction (ASE) for the extraction of DCF from wastewater sludge were compared and ASE with 95.6 ± 7% recovery was effective over USE with 86 ± 4% recovery. The fate and partitioning of DCF in wastewater (WW) and wastewater sludge (WWS) in wastewater treatment plant was also monitored at various stages of treatment in Quebec Urban community wastewater treatment plant. DCF exhibited affinity towards WW than WWS with a presence about 60% of DCF in WW in contrary with theoretical prediction (LogKow=4.51). PMID:26805597

  18. Identification of glyceollin metabolites derived from conjugation with glutathione and glucuronic acid in rats by on-line liquid chromatography-electrospray ionization tandem mass spectrometry

    Science.gov (United States)

    Glyceollin-related metabolites produced in rats following oral glyceollin administration were screened and identified by precursor and product ion scanning using liquid chromatography, coupled on-line with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS), to identify all glyceollin me...

  19. Analysis of [3′,3′-d2]-nicotine and [3′,3′-d2]-cotinine by capillary liquid chromatography-electrospray tandem mass spectrometry

    OpenAIRE

    Murphy, Sharon E.; Villalta, Peter; Ho, Sing-Wei; von Weymarn, Linda B.

    2007-01-01

    A selective and sensitive LC/MS/MS assay was developed for the quantification of d2-nicotine and d2-cotinine in plasma of current and past smokers administered d2-nicotine. After solid phase extraction and liquid liquid extraction, HPLC separation was achieved on a capillary hydrophilic interaction chromatography phase column. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated for d2-nicotine (0.03 to 6.0 ng/...

  20. Analysis of caged xanthones from the resin of Garcinia hanburyi using ultra-performance liquid chromatography/electrospray ionization quadrupole time-of-flight tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhou Yan [Hong Kong Jockey Club Institute of Chinese Medicine, Shatin, Hong Kong (China); Liu Xin [Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu 610041, Sichuan Province (China); Yang Jing [School of Chemistry and Chemical Technology, Shanghai Jiao Tong University, Shanghai 200240 (China); Han Quanbin; Song Jingzheng; Li Songlin; Qiao Chunfeng [Hong Kong Jockey Club Institute of Chinese Medicine, Shatin, Hong Kong (China); Ding Lisheng [Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu 610041, Sichuan Province (China)], E-mail: lsding@cib.ac.cn; Xu Hongxi [Hong Kong Jockey Club Institute of Chinese Medicine, Shatin, Hong Kong (China)], E-mail: xuhongxi@hkjcicm.org

    2008-11-23

    On-line ultra high-performance liquid chromatography (UHPLC) coupled with electrospray quadrupole time-of-flight tandem mass spectrometry (ESI-QTOF-MS/MS/MS) has been developed for the analysis of a series of caged xanthones in the resin of Garcinia hanburyi. The fragmentation of protonated molecular ions for 12 known cadged xanthones was carried out using low-energy collision-induced electrospray ionization tandem mass spectrometry. It was found that Retro-Diels-Alder rearrangement occurred in the CID processes and produced the characteristic fragment ions, which are especially valuable for the identification of this class of xanthones. The fragmentation differential between some cis-, trans-isomers was uncovered. Computation methods were utilized to rationalize the observed MS behaviors. On-line UHPLC-ESI-MS/MS/MS method has proved to be rapid and efficient in that within 6 min, 15 caged scaffold xanthones, including three pairs of epimers and four pairs of isomers in gamboges, were effectively separated and identified. Among them, two known, namely isogambogenin (13) and isomorellinol (14) and one likely new caged Garcinia xanthones from the Garcinia hanburyi were tentatively characterized based on the tandem mass spectra of known ones.

  1. Analysis of caged xanthones from the resin of Garcinia hanburyi using ultra-performance liquid chromatography/electrospray ionization quadrupole time-of-flight tandem mass spectrometry

    International Nuclear Information System (INIS)

    On-line ultra high-performance liquid chromatography (UHPLC) coupled with electrospray quadrupole time-of-flight tandem mass spectrometry (ESI-QTOF-MS/MS/MS) has been developed for the analysis of a series of caged xanthones in the resin of Garcinia hanburyi. The fragmentation of protonated molecular ions for 12 known cadged xanthones was carried out using low-energy collision-induced electrospray ionization tandem mass spectrometry. It was found that Retro-Diels-Alder rearrangement occurred in the CID processes and produced the characteristic fragment ions, which are especially valuable for the identification of this class of xanthones. The fragmentation differential between some cis-, trans-isomers was uncovered. Computation methods were utilized to rationalize the observed MS behaviors. On-line UHPLC-ESI-MS/MS/MS method has proved to be rapid and efficient in that within 6 min, 15 caged scaffold xanthones, including three pairs of epimers and four pairs of isomers in gamboges, were effectively separated and identified. Among them, two known, namely isogambogenin (13) and isomorellinol (14) and one likely new caged Garcinia xanthones from the Garcinia hanburyi were tentatively characterized based on the tandem mass spectra of known ones

  2. Characterisation by liquid chromatography-electrospray tandem mass spectrometry of anthocyanins in extracts of Myrtus communis L. berries used for the preparation of myrtle liqueur.

    Science.gov (United States)

    Montoro, Paola; Tuberoso, Carlo I G; Perrone, Angela; Piacente, Sonia; Cabras, Paolo; Pizza, Cosimo

    2006-04-21

    Anthocyanins in extracts of berries of Myrtus communis, prepared following a typical Sardinia myrtle liqueur recipe, were identified and quantified by HPLC coupled with electrospray/tandem mass spectrometry using, respectively, an ion trap and a triple quadrupole mass analyser. The fragmentation patterns of the anthocyanidins were dependent on the MS technique employed, and differed considerably from those previously reported. The anthocyanin profile of five anthocyanin glucosides and four anthocyanin arabinosides, the latter not previously identified in this specie, was specific for myrtle berry extracts. The quantitative compositions of extracts of myrtle berries derived from different geographical areas in Italy were compared. PMID:16376912

  3. Optimized combination of dilution and refined QuEChERS to overcome matrix effects of six types of tea for determination eight neonicotinoid insecticides by ultra performance liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Jiao, Weiting; Xiao, Yu; Qian, Xiaosan; Tong, Mengmeng; Hu, Yizheng; Hou, Ruyan; Hua, Rimao

    2016-11-01

    Liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) is a primary tool for analysis of low volatility compounds in complex matrices. However, complex matrices, such as different types of tea, complicate analysis through ionization suppression or enhancement. In this study, sample preparation by a refined QuEChERS method combined with a dilution strategy removed almost all matrix effects caused by six types of tea. Tea samples were soaked with water and extracted with acetonitrile, cleaned up with a combination of PVPP (160mg) and GCB (20mg), and dried. Dried extracts were diluted with 20mL acetonitrile/water (15:85, v/v) before analysis by UPLC-MS/MS. The average recoveries of eight neonicotinoid insecticides (dinotefuran, nitenpyram, thiamethoxam, imidacloprid, clothianidin, imidaclothiz, acetamiprid, and thiacloprid) ranged from 66.3 to 108.0% from tea samples spiked at 0.01-0.5mgkg(-1). Relative standard deviations were below 16% for all recovery tests. The limit of quantification ranged from 0.01 to 0.05mgkg(-1). PMID:27211616

  4. Can Edman degradation be used for quantification? Isotope-dilution liquid chromatography-electrospray ionization tandem mass spectrometry and the long-term stability of 20 phenylthiohydantoin-amino acids.

    Science.gov (United States)

    Satoh, Ryo; Goto, Takaaki; Lee, Seon Hwa; Oe, Tomoyuki

    2013-10-01

    Edman degradation is a well-known method for obtaining amino acid (AA) sequences from a peptide by means of sequential reactions that release the N-terminal AAs from the peptide as a phenylthiohydantoin (PTH) derivative. Because of unexpected loss during the reaction and handling, there are few reports of use of this reaction for quantification. This manuscript describes the development of isotope-dilution liquid chromatography-electrospray ionization tandem mass spectrometry for 20 PTH-AA derivatives, and long-term stability testing of PTH-AAs to ensure quantitative quality in the reaction. The 20 corresponding [(13)C6]-PTH-AAs were prepared by use of a one-pot reaction involving a mixture of [(13)C6]-Edman reagent and 20 AAs. Good linearity was observed for standard curves for the PTH-AAs, using the corresponding [(13)C6]-PTH-AAs as internal standards (1-100 pmol per injection, r(2) = 0.989-1.000). Serum albumin (human), pepsin (porcine stomach mucosa), α-casein (bovine milk), ribonuclease A (bovine), lysozyme (chicken egg white), and insulin (bovine) subjected to Edman degradation were examined as model proteins and peptides for N-terminal AA analysis. The results of the impurity test were satisfactory. Yield from the entire reaction with human serum albumin was estimated to be at least 75%, indicating great potential for absolute quantification of proteins without protein standards. PMID:23545858

  5. Screening of polycyclic polyprenylated acylphloroglucinols from Garcinia species using precursor ion discovery (PID) scan and ultra performance liquid chromatography electrospray ionization Q-TOF tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Yan; Huang, Sheng-Xiong; Song, Jing-Zheng; Qiao, Chun-Feng; Li, Song-Lin; Han, Quan-Bin; Xu, Hong-Xi

    2009-10-01

    A strategy was newly developed to rapidly screen polycyclic polyprenylated acyl-phloroglucinols (PPAPs) from the plant matrices of nine Garcinia species using ultra-performance liquid chromatography (UPLC) coupled with comprehensive mass spectrometric approaches including precursor ion discovery (PID) and tandem mass (MS/MS) scans. The PPAPs share the same diagnostic product ion at m/z 177.02 in positive MS/MS scan, which may be increased as the base peak by ramping the cone voltage from 45 to 100 V. With this ramping cone voltage PID scan, it is feasible to selectively screen the PPAPs from 29 samples of nine Garcinia species. This approach has proven to be a powerful, highly selective, and sensitive tool for rapid screening and detection of nontargeted components in natural products before the purification and structural elucidation process. PMID:19643632

  6. Determination of phosphatidylethanolamine molecular species in various food matrices by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS2).

    Science.gov (United States)

    Zhou, Li; Zhao, Minjie; Ennahar, Saïd; Bindler, Françoise; Marchioni, Eric

    2012-04-01

    A liquid chromatographic-electrospray ionization-tandem mass spectrometric (LC-ESI-MS(2)) method has been developed for determination of the molecular species of phosphatidylethanolamine (PE) in four food matrices (soy, egg yolk, ox liver, and krill oil). The extraction and purification method consisted of a pressurized liquid extraction procedure for total lipid (TL) extraction, purification of phospholipids (PLs) by adsorption on a silica gel column, and separation of PL classes by semi-preparative normal-phase HPLC. Separation and identification of PE molecular species were performed by reversed-phase HPLC coupled with electrospray ionization tandem mass spectrometry (ESI-MS(2)). Methanol containing 5 mmol L(-1) ammonium formate was used as the mobile phase. A variety of PE molecular species were detected in the four food matrices. (C16:0-C18:2)PE, (C18:2-C18:2)PE, and (C16:0-C18:1)PE were the major PE molecular species in soy. Egg yolk PE contained (C16:0-C18:1)PE, (C18:0-C18:1)PE, (C18:0-C18:2)PE, and (C16:0-C18:2)PE as the major molecular species. Ox liver PE was rich in the species (C18:0-C18:1)PE, (C18:0-C20:4)PE, and (C18:0-C18:2)PE. Finally, krill oil which was particularly rich in (C16:0(alkyl)-C22:6(acyl))plasmanylethanolamine (PakE), (C16:0-C22:6)PE, and (C16:0-C20:5)PE, seemed to be an interesting potential source for supplementation of food with eicosapentaenoic acid and docosahexaenoic acid. PMID:22349329

  7. Validation of a liquid chromatography-electrospray ionization tandem mass spectrometric method to determine six polyether ionophores in raw, UHT, pasteurized and powdered milk.

    Science.gov (United States)

    Pereira, Mararlene Ulberg; Spisso, Bernardete Ferraz; Jacob, Silvana do Couto; Monteiro, Mychelle Alves; Ferreira, Rosana Gomes; Carlos, Betânia de Souza; da Nóbrega, Armi Wanderley

    2016-04-01

    This study aimed to validate a method developed for the determination of six antibiotics from the polyether ionophore class (lasalocid, maduramicin, monensin, narasin, salinomycin and semduramicin) at residue levels in raw, UHT, pasteurized and powdered milk using QuEChERS extraction and high performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS). The validation was conducted under an in-house laboratory protocol that is primarily based on 2002/657/EC Decision, but takes in account the variability of matrix sources. Overall recoveries between 93% and 113% with relative standard deviations up to 16% were obtained under intermediate precision conditions. CCα calculated values did not exceed 20% the Maximum Residue Limit for monensin and 25% the Maximum Levels for all other substances. The method showed to be simple, fast and suitable for verifying the compliance of raw and processed milk samples regarding the limits recommended by Codex Alimentarius and those adopted in European Community for polyether ionophores. PMID:26593474

  8. Ultra-performance liquid chromatography electrospray ionization–tandem mass spectrometry method for the simultaneous determination of itraconazole and hydroxy itraconazole in human plasma

    Directory of Open Access Journals (Sweden)

    Ashish Dwivedi

    2014-10-01

    Full Text Available A highly sensitive, selective, and precise ultra-performance liquid chromatography tandem mass spectrometry method was developed and validated for simultaneous quantification of itraconazole and hydroxy itraconazole in human plasma by a single liquid–liquid extraction step. The precursor to product ion transitions of m/z 705.3/392.3, m/z 721.2/408.3 and m/z 708.2/435.4 were used to detect and quantify itraconazole, hydroxy itraconazole and itraconazole-d3 respectively. The lower limit of quantitation was found to be 0.500 ng/mL for itraconazole and 1.00 ng/mL for hydroxy itraconazole. The mean recoveries for itraconazole and hydroxy itraconazole were found to be 100.045% and 100.021%, respectively. This developed method with a chromatographic run time of 2.0 min was successfully applied to a bioequivalence study of 100 mg itraconazole capsule.

  9. Trace analysis of trimethoprim and sulfonamide, macrolide, quinolone, and tetracycline antibiotics in chlorinated drinking water using liquid chromatography electrospray tandem mass spectrometry

    Science.gov (United States)

    Ye, Z.; Weinberg, H.S.; Meyer, M.T.

    2007-01-01

    A multirun analytical method has been developed and validated for trace determination of 24 antibiotics including 7 sulfonamides, 3 macrolides, 7 quinolones, 6 tetracyclines, and trimethoprim in chlorine-disinfected drinking water using a single solid-phase extraction method coupled to liquid chromatography with positive electrospray tandem mass spectrometry detection. The analytes were extracted by a hydrophilic-lipophilic balanced resin and eluted with acidified methanol (0.1% formic acid), resulting in analyte recoveries generally above 90%. The limits of quantitation were mostly below 10 ng/L in drinking water. Since the concentrated sample matrix typically caused ion suppression during electrospray ionization, the method of standard addition was used for quantitation. Chlorine residuals in drinking water can react with some antibiotics, but ascorbic acid was found to be an effective chlorine quenching agent without affecting the analysis and stability of the antibiotics in water. A preliminary occurrence study using this method revealed the presence of some antibiotics in drinking waters, including sulfamethoxazole (3.0-3.4 ng/L), macrolides (1.4-4.9 ng/L), and quinolones (1.2-4.0 ng/L). ?? 2007 American Chemical Society.

  10. Comparison of rapid liquid chromatography-electrospray ionization-tandem mass spectrometry methods for determination of glycoalkaloids in transgenic field-grown potatoes.

    Science.gov (United States)

    Zywicki, Britta; Catchpole, Gareth; Draper, John; Fiehn, Oliver

    2005-01-15

    Two rapid methods for highly selective detection and quantification of the two major glycoalkaloids in potatoes, alpha-chaconine and alpha-solanine, were compared for robustness in high-throughput operations for over 1000 analytical runs using potato tuber samples from field trials. Glycoalkaloids were analyzed using liquid chromatography coupled to tandem mass spectrometry in multiple reaction monitoring mode. An electrospray interface was used in the detection of glycoalkaloids in positive ion mode. Classical reversed phase (RP) and hydrophilic interaction (HILIC) columns were investigated for chromatographic separation, ruggedness, recovery, precision, and accuracy. During the validation procedure both methods proved to be precise and accurate enough in relation to the high degree of endogenous biological variability found for field-grown potato tubers. However, the RP method was found to be more precise, more accurate, and, more importantly, more rugged than the HILIC method for maintaining the analytes' peak shape symmetry in high-throughput operation. When applied to the comparison of six classically bred potato cultivars to six genetically modified (GM) lines engineered to synthesize health beneficial inulins, the glycoalkaloid content in potato peels of all GM lines was found within the range of the six cultivars. We suggest complementing current unbiased metabolomic strategies by validating quantitative analytical methods for important target analytes such as the toxic glycoalkaloids in potato plants. PMID:15620882

  11. Liquid chromatography-electrospray ionization tandem mass spectrometry for on-line characterization, monitoring and isotopic profiling of the main selenium-metabolite in human urine after consumption of Se-rich and Se-enriched food

    International Nuclear Information System (INIS)

    The metabolism of selenium (Se) in the human body has yet not completely been unravelled and hence, an efficient method for characterization and on-line monitoring of the main Se-compound in human urine after consumption of Se-rich food was developed. Total Se-concentration in human urine after consumption of several Se-rich products was measured with inductively coupled plasma mass spectrometry (ICP-MS). The highest Se concentration in urine was observed after 4-10 h. The urine samples were brought onto a reversed phase column and the Se was detected by ICP-MS. Parameters for liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS) measurements were optimized by using commercially available sugars, because it is known that some of the urinary metabolites contain a sugar moiety. In order to characterize the predominant Se-metabolite, it was necessary to extensively clean-up the sample and preconcentrate the species. The main metabolite was measured on its precursor ion on three different m/z according to three isotopes of Se. Relative peak surfaces matched the relative abundances of the isotopes. The product ions could be measured in a human urine sample in accordance to the product ions of the commercially available sugars. Moreover, the evidence of a selenosugar was demonstrated by the use of the Se-isotopes when measuring the product ions. LC-ESI-MS-MS was proven to be very efficient for the characterization of the main urinary Se-metabolite and can be used for on-line monitoring of the compound in urine samples. The method can be extended for clinical screening after consumption of Se-(en)rich(ed) food by use of the Se-isotopic profile and/or of the typical product ions of (methyl)-N-acetyl-hexosamines

  12. Precolumn derivatization reagents for high-speed analysis of amines and amino acids in biological fluid using liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Shimbo, Kazutaka; Oonuki, Takashi; Yahashi, Akihisa; Hirayama, Kazuo; Miyano, Hiroshi

    2009-05-01

    A rapid analytical method for amines and amino acids was developed, involving derivatization with the novel reagent 3-aminopyridyl-N-hydroxysuccinimidyl carbamate (APDS), followed by reversed-phase high-performance liquid chromatography and electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS). More than 100 different analytes with amino groups, including amino acids in biological fluids such as mammalian plasma, could be measured within 10 min. The analytes were easily derivatized with APDS under the mild conditions. Selective reaction monitoring of ESI-MS/MS in positive mode was carried out to include the transitions of all of the protonated molecular ions of analytes derivatized with APDS to the common fragment at m/z 121, which was derived from the amino pyridyl moiety of the reagent. We evaluated the retention time precision, the quantification limits, the linearity, the intra- and inter-day precisions and the accuracy of 22 typical amino acids found in biological fluids, by analyzing a standard amino acid mixture and rat plasma. The intra-day relative standard deviations (RSDs) of the retention times of the 22 amino acids and their internal standards were within 0.9% and the inter-day RSDs were less than 1.1%, except for asparagines, with an RSD of 1.9%. The intra-day and inter-day RSDs of amino acid analyses in rat plasma were within 8.0% and 4.5%, respectively. The method, which facilitates the amino acid analysis of more than 100 samples in a day, represents an alternative to traditional amino acid analysis techniques, such as chromatography using postcolumn derivatization by ninhydrin. PMID:19350529

  13. Identification and quantification of glucosamine in rabbit cartilage and correlation with plasma levels by high performance liquid chromatography-electrospray ionization-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Graphical abstract: Highlights: → Optimization of an HPLC-ESI-MS/MS method for glucosamine in rabbit cartilage. → Application of the method to an in-vivo study. → Glucosamine presence in cartilage in physiological condition. → Significant increase of cartilage glucosamine concentration after dosing. → Good correlation between cartilage glucosamine levels and plasma concentrations. - Abstract: A new HPLC-ESI-MS/MS method for the determination of glucosamine (2-amino-2-deoxy-D-glucose) in rabbit cartilage was developed and optimized. Glucosamine was extracted from cartilage by cryogenic grinding followed by protein precipitation with trichloroacetic acid. The HPLC separation was achieved with a polymer-based amino column using a mobile phase composed of 10 mM ammonium acetate (pH 7.5)-acetonitrile (20:80%, v/v) at 0.3 mL min-1 flow rate. D-[1-13C]Glucosamine was used as internal standard. Selective detection was performed by tandem mass spectrometry with electrospray source, operating in positive ionization mode and in multiple reaction monitoring acquisition (m/z 180 → 72 and 181 → 73 for glucosamine and internal standard, respectively). Limit of quantification was 0.045 ng injected, corresponding to 0.25 μg g-1 in cartilage. Linearity was obtained up to 20 μg g-1 (R2 > 0.991). Precision values (%R.S.D.) were -1 (n = 6). Glucosamine was present in cartilage in physiological condition before the treatment. After dosing, mean concentration of cartilage glucosamine significantly increased from 461 to 1040 ng g-1. Cartilage glucosamine levels resulted to be well correlated with plasma concentrations, which therefore are useful to predict the target cartilage concentration and its pharmacological activity.

  14. Quantification of new antiepileptic drugs by liquid chromatography/electrospray ionization tandem mass spectrometry and its application to cellular uptake experiment using human placental choriocarcinoma BeWo cells.

    Science.gov (United States)

    Furugen, Ayako; Kobayashi, Masaki; Nishimura, Ayako; Takamura, Shigeo; Narumi, Katsuya; Yamada, Takehiro; Iseki, Ken

    2015-10-01

    A method for quantification of new antiepileptic drugs, including lamotrigine (LTG), levetiracetam (LEV), gabapentin (GBP), and topiramate (TPM), in cellular samples, using liquid chromatography/electrospray ionization tandem mass spectrometry was developed to better understand the membrane transport mechanisms of these drugs. Cell lysate was deproteinized by methanol containing LEV-d3 as an internal standard (IS). Chromatographic separation was performed on a C18 column using gradient elution with methanol-water-formic acid (10:90:0.1, v/v/v) and methanol-formic acid (100:0.1, v/v). Analytes were detected in positive ion electrospray mode with selected reaction monitoring (SRM). This method was applicable for a linear range of 5 to 500pmol for LTG; 5 to 1000pmol for LEV; 10 to 10,000pmol for GBP; and 5 to 5000pmol for TPM. The intra-day precision, inter-day precision, and accuracy data were assessed and found to be acceptable. This developed and validated method was then successfully applied to the investigation of uptake of the new antiepileptic drugs in placental choriocarcinoma BeWo cells. The intracellular concentration of these drugs in BeWo cells, accumulating over 30min at 37°C was in the order of GBP>LTG>LEV≈TPM. Furthermore, the uptake of GBP at 4°C was much lower than that at 37°C. The uptake of GBP was saturated at high concentrations. The kinetic parameters calculated for GBP uptake in BeWo cells were determined as Km of 105.4±6.4μM and Vmax at 8153±348pmol/mg protein/min. The novel method described here should enable investigators to elucidate the transport mechanisms of these antiepileptic drugs in BeWo cells. PMID:26343016

  15. Rapid and simultaneous analysis of ten aromatic amines in mainstream cigarette smoke by liquid chromatography/electrospray ionization tandem mass spectrometry under ISO and "Health Canada intensive" machine smoking regimens.

    Science.gov (United States)

    Xie, Fuwei; Yu, Jingjing; Wang, Sheng; Zhao, Ge; Xia, Qiaoling; Zhang, Xiaobing; Zhang, Shusheng

    2013-10-15

    Ten primary aromatic amines (AAs) in mainstream cigarette smoke under both ISO and "Health Canada intensive" machine smoking regimens were determined in this work, which were suspected to be carcinogenic compounds. The measured AAs included aniline, ortho-toluidine, meta-toluidine, para-toluidine, 1-naphthylamine, 2-naphthylamine, 3-aminobiphenyl, 4-aminobiphenyl, meta-phenylenediamine and meta-anisidine. For rapidly and sensitively analyzing these AAs, a liquid chromatography-electrospray ionization tandem mass spectrometric (LC-MS/MS) method coupled with solid phase extraction (SPE) was developed. The particulate phase of mainstream cigarette smoke was collected on a Cambridge filter pads, while the gas phase was trapped by 25 mL 5% HCl solution. Then, the pad was extracted in an ultrasonic bath with the impinger HCl solution. After being neutralized with NaOH, the extract was purified with a HLB solid phase extraction column, and then was analyzed with LC-MS/MS using isotope-labeled internal standard. The overall sample pretreatment and analysis time was less than 1.5h. The limits of detection for all targets ranged from 0.05 ng cig(-1) to 0.96 ng cig(-1) with the recoveries in the range of 75.0-131.8%. And the intra-day and inter-day precisions were less than 10% and 16%, respectively. Under HCI machine smoking regimen, the AAs yields in mainstream cigarette smoke were much higher and the average increases were greater than 100% compared with those under ISO smoking condition. PMID:24054615

  16. Determination of gardenia yellow colorants in soft drink, pastry, instant noodles with ultrasound-assisted extraction by high performance liquid chromatography-electrospray ionization tandem mass spectrum.

    Science.gov (United States)

    Zhou, Wei-E; Zhang, Yuan; Li, Yang; Ling, Yun; Li, Hong-Na; Li, Shao-Hui; Jiang, Shou-Jun; Ren, Zhi-Qin; Huang, Zhi-Qiang; Zhang, Feng

    2016-05-13

    A novel, rapid and simple analytical method was developed for the quantitative determination of crocin, crocetin and geniposide in soft drink, pastry and instant noodles. The solid samples were relatively homogenized into powders and fragments. The gardenia yellow colorants were successively extracted with methanol using ultrasound-assisted extraction. The analytes were quantitatively measured in the extracts by liquid chromatography coupled with electrospray ionization tandem mass spectrometry. High correlation coefficients (r(2)>0.995) of crocin, crocetin and geniposide were obtained within their linear ranges respectively (50-1000ng/mL, 50-1000ng/mL, 15-240ng/mL) by external standard method. The limits of detection (LODs) were 0.02μg/g for crocin, 0.01μg/g for crocetin and 0.002μg/g for geniposide. And the limits of quantitation (LOQs) were in the ranges of 0.05-0.45μg/g for crocin, and in the ranges of 0.042-0.32μg/g for crocetin, and in the ranges of 0.02-0.15μg/g for geniposide in soft drink, pastry and instant noodles samples. The average recoveries of crocin, crocetin and geniposide ranged from 81.3% to 117.6% in soft drink, pastry and instant noodles. The intra- and inter-day precisions were respectively in the range of 1.3-4.8% and 1.7-11.8% in soft drink, pastry and instant noodle. The developed methods were successfully validated and applied to the soft drink, pastry, and instant noodles collected from the located market in Beijing from China. Crocin, crocetin and geniposide were detected in the collected samples. The average concentrations ranged from 0.84 to 4.20mg/g for crocin, and from 0.62 to 3.11mg/g for crocetin, and from 0.18 to 0.79mg/g for gardenia in various food samples. The method can provide evidences for government to determine gardenia yellow pigments and geniposide in food. PMID:27086566

  17. Determination of synthetic phenolic antioxidants and relative metabolites in sewage treatment plant and recipient river by high performance liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Liu, Runzeng; Ruan, Ting; Song, Shanjun; Lin, Yongfeng; Jiang, Guibin

    2015-02-13

    Robust analytical methods were developed for the determination of eight emerging synthetic phenolic antioxidants (SPAs) and three metabolites in sewage sludge, effluent and river water matrices. Accelerated solvent extraction was employed for the extraction of the target analytes from sludge, dichloromethane/hexane=3:1 (extraction solvent) and 90°C (extraction temperature) were used after optimization. Silica gel packed column was chosen for the subsequent clean-up procedure for sludge extract. For the water sample analysis, liquid-liquid extraction combined with silica gel clean-up was used. The targets were determined by optimized high performance liquid chromatography-tandem mass spectrometry method in negative electrospray ionization mode. The method quantification limits of the 11 analytes ranged from 0.1 to 23 ng/L, 0.1 to 20 ng/L and 0.1 to 15 ng/g for sewage effluent, river water and sludge matrices, respectively. The total recoveries of the pretreatment varied from 63 to 106%, with relative standard deviations less than 17% for the three matrices at different spiking levels. Nine targets including 2,6-di-tert-butyl-4-methylphenol (BHT), 3,5-di-tert-butyl-4-hydroxybenzaldehyde (BHT-CHO), 2,6-di-tert-butyl-1,4-benzoquinone (BHT-Q), 2,6-di-tert-butyl-4-hydroxy-4-methyl-2,5-cyclohexadienone (BHT-quinol), 3-tert-butyl-4-hydroxyanisole (BHA), 4-tert-octylphenol (4-tOP), 2,2'-methylenebis(6-tert-butyl-4-methylphenol) (AO 2246), 4,4'-butylidenebis(2-(1,1-dimethylethyl)-5-methyl-phenol) (AO 44B25) and 1,3,5-trimethyl-2,4,6-tris(3,5-di-tert-butyl-4-hydroxybenzyl)benzene (AO 330) were identified in the collected samples, with concentrations ranging 1.1-2325 ng/g and 0.4-2510 ng/L for sludge and water matrices, respectively. Sewage effluent was considered as a possible contamination source of certain SPA homologues and relative metabolites to the recipient aquatic systems. PMID:25614188

  18. Identification and quantification of glucosamine in rabbit cartilage and correlation with plasma levels by high performance liquid chromatography-electrospray ionization-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Pastorini, Elisabetta; Vecchiotti, Stefania; Colliva, Carolina [Department of Pharmaceutical Sciences, University of Bologna, Via Belmeloro 6, I-40126 Bologna (Italy); Persiani, Stefano [Rottapharm-Madaus, Via Valosa di Sopra 9, 20900 Monza Brianza (Italy); Rotini, Roberto; Roatti, Giulia; Zaccarelli, Lorenzo [Division of Orthopedic Surgery (Section B), Rizzoli Orthopaedic Institute, Via Pupilli 1, 40136 Bologna (Italy); Rovati, Lucio Claudio [Rottapharm-Madaus, Via Valosa di Sopra 9, 20900 Monza Brianza (Italy); Roda, Aldo, E-mail: aldo.roda@unibo.it [Department of Pharmaceutical Sciences, University of Bologna, Via Belmeloro 6, I-40126 Bologna (Italy)

    2011-06-10

    Graphical abstract: Highlights: > Optimization of an HPLC-ESI-MS/MS method for glucosamine in rabbit cartilage. > Application of the method to an in-vivo study. > Glucosamine presence in cartilage in physiological condition. > Significant increase of cartilage glucosamine concentration after dosing. > Good correlation between cartilage glucosamine levels and plasma concentrations. - Abstract: A new HPLC-ESI-MS/MS method for the determination of glucosamine (2-amino-2-deoxy-D-glucose) in rabbit cartilage was developed and optimized. Glucosamine was extracted from cartilage by cryogenic grinding followed by protein precipitation with trichloroacetic acid. The HPLC separation was achieved with a polymer-based amino column using a mobile phase composed of 10 mM ammonium acetate (pH 7.5)-acetonitrile (20:80%, v/v) at 0.3 mL min{sup -1} flow rate. D-[1-{sup 13}C]Glucosamine was used as internal standard. Selective detection was performed by tandem mass spectrometry with electrospray source, operating in positive ionization mode and in multiple reaction monitoring acquisition (m/z 180 {yields} 72 and 181 {yields} 73 for glucosamine and internal standard, respectively). Limit of quantification was 0.045 ng injected, corresponding to 0.25 {mu}g g{sup -1} in cartilage. Linearity was obtained up to 20 {mu}g g{sup -1} (R{sup 2} > 0.991). Precision values (%R.S.D.) were <10%. Accuracy (% bias) ranged from -6.0% to 12%. Mean recoveries obtained at 3 concentration levels were higher than 81% (%R.S.D. {<=} 8%). The method was applied to measure glucosamine levels in rabbit cartilage and plasma after single oral administration of glucosamine sulfate at a dose of 98 mg kg{sup -1} (n = 6). Glucosamine was present in cartilage in physiological condition before the treatment. After dosing, mean concentration of cartilage glucosamine significantly increased from 461 to 1040 ng g{sup -1}. Cartilage glucosamine levels resulted to be well correlated with plasma concentrations, which

  19. Determination of carnitine and acylcarnitines in urine by high-performance liquid chromatography-electrospray ionization ion trap tandem mass spectrometry.

    Science.gov (United States)

    Vernez, Laurence; Hopfgartner, Gérard; Wenk, Markus; Krähenbühl, Stephan

    2003-01-17

    A high-performance liquid chromatography-mass spectrometry method has been developed for the simultaneous determination of native carnitine and eight acylcarnitines in urine. The procedure uses a solid-phase extraction on a cation-exchange column and the separation is performed without derivatization within 17 min on a reversed-phase C8 column in the presence of a volatile ion-pairing reagent. The detector was an ion trap mass spectrometer and quantification was carried out in the MS-MS mode. Validation was done for aqueous standards at ranges between 0.75 and 200 micromol/l, depending on the compound. Carnitine was quantified in urine and comparison with a radioenzymatic assay gave a satisfactory correlation (R2 = 0.981). The assay could be successfully applied to the diagnostic of pathological acylcarnitines profile of metabolic disorders in urines of patients suffering from different organic acidurias. PMID:12564691

  20. 液相色谱-串联质谱法测定保健食品中维生素B12%Determination of vitamin B12 in function foods by liquid chromatography electrospray ionization tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    林宏琳; 华永有; 黄宏南

    2011-01-01

    目的 建立测定保健食品中维生素B12的液相色谱-串联质谱法.方法 样品添加内标人参皂苷Re溶液,固相萃取法( SPE)对试样进行富集、净化,以甲醇(A)和纯水(B)为流动相经Bio Basic-18 PIONEER柱(150 mm×2.1 mm,5μm)梯度洗脱分离,串联离子阱质谱在电喷雾电离正离子(ESI+)-全扫描(full)-二级质谱(MS/MS)模式下按内标法测定.结果 维生素B12在50~500 ng/ml范围内具有良好的线性,相关系数r=0.992,回收率75.2% ~ 89.5%,精密度3.6%~5.9%,检出限为5 ng/g,定量限为16 ng/g.结论本法可应用于保健食品的检测或产品质量控制.%Objective To establish a method of determining vitamin B12 in health food products by liquid chromatography electrospray ionization tandem mass spectrometry (LC-MS/MS). Methods After mixing samples with internal standard solution of ginsenoside Re, the mixtures of samples were extracted by solid phase extraction, and separated on a Bio Basic-18 PIONEER column (ISO mm ×2. 1 mm, 5 u.m) by a mobile phase of methanol ( A) + water ( B) with the gradient elution program. Detection was carried out by a liquid chromatography coupled electrospray ionization and ion trap mass spectrometry with ESI + , MS/MS and full scan mode. Results Calibration curve was linear within the range of 50-SOOng/ml with a correlation coefficient of more than 0. 99; the limit of detection ( LOD) was 5 ng/g and the limit of quantification ( LOQ) was 16 ng/g. The extraction recoveries were 75.2%-88.5%, RSDs were 3.6% -5.9%. Conclusion This method could meet the requirements of domestic and international laws and regulations, and could be used in the determination of VBI2 in health food products or for the quality control of the products.

  1. Method development for the determination of selected pesticides on tobacco by high-performance liquid chromatography-electrospray ionisation-tandem mass spectrometry.

    Science.gov (United States)

    Mayer-Helm, Bernhard; Hofbauer, Ludwig; Müller, Jutta

    2008-02-15

    A method was developed for the quantitative determination of alachlor, benalaxyl, clomazone, diflubenzuron, dimethomorph, diphenamid, ethofumesate, metalaxyl, methoprene, metobromuron and piperonyl butoxide on tobacco. The pesticides were extracted with water and methanol from five different types of tobacco. The extracts were purified by partition on an extraction cartridge containing diatomaceous earth. The purified extracts were analysed by reversed-phase high-performance liquid chromatography connected to an atmospheric pressure ionisation-electrospray-triple quadrupole mass spectrometer operating in the positive ion mode. Two different transitions and their relative intensities were monitored for unambiguous identification. All pesticides presented overall recovery rates between 35% and 110%. The trueness is near 100% and the interday precision is below 15%. The limits of quantifications are equal or below the guidance residue levels proposed by the Agrochemical Advisory Committee of CORESTA, an association of organisations having scientific research relative to tobacco. PMID:18371768

  2. Phospholipidomic identification of potential serum biomarkers in dengue fever, hepatitis B and hepatitis C using liquid chromatography-electrospray ionization-tandem mass spectrometry.

    Science.gov (United States)

    Khedr, Alaa; Hegazy, Maha A; Kammoun, Ahmed K; Shehata, Mostafa A

    2016-01-15

    The serum phospholipid (PL) profiles of healthy volunteers (HE) and patients with recently diagnosed dengue fever (DF), hepatitis B (HBV), and hepatitis C (HCV) were investigated using liquid chromatography-ion trap-mass spectrometry (LC-IT-MS) and liquid chromatography-triple quad-mass spectrometry (LC-TQ-MS). Major PLs, including lyso-phosphatidylcholins (LPCs), phosphatidylcholins (PCs), phosphatidylinositols (PIs), phosphatidylethanolamines (PEs) and phosphatidylserines (PSs), were characterized in human serum using LC-IT-MS. Thirty-five PLs were quantified using seven non-endogenous odd-carbon PL standards. An MS search protocol for the identification of PLs is described. The analytical method was optimized to achieve maximum recovery and detection. PLs were detected with minimal ionization suppression. The PLs species were characterized on the basis of (i) MS(2) peaks due to polar head, (ii) precursor ion or neutral loss scans, (iii) identification of fatty acid, (iv) identification of sn-1 and sn-2 fatty acid. The quantitation data were subjected to principal component analysis (PCA), and a significant difference was observed between the PL profiles of the investigated diseases and those of HE subjects. The significance of the changes in each lipid among the four groups was statistically assessed using one-way analysis of variance (ANOVA) followed by Bonferroni post hoc multiple comparison. The serum profiles of 28 PLs were determined to be significantly different and enabled the discrimination between HE individuals and the studied patients. Potentially dysregulated PLs were considered as differentiating biomarkers to diagnose DF, HBV, and HCV. PMID:26708624

  3. Detection and confirmation of milk adulteration with cheese whey using proteomic-like sample preparation and liquid chromatography-electrospray-tandem mass spectrometry analysis.

    Science.gov (United States)

    Campos Motta, T M; Hoff, R B; Barreto, F; Andrade, R B S; Lorenzini, D M; Meneghini, L Z; Pizzolato, T M

    2014-03-01

    Caseinomacropeptide (CMP) is a peptide released by chymosin in cheese production, remaining in whey. Thus, CMP can be used as a biomarker to fluid milk adulteration through whey addition. Commonly, CMP is analyzed by reversed phase (RP-HPLC) or size-exclusion chromatography (SEC). However, some psychrotropic microorganisms - specially Pseudomonas fluorescens - when present in storaged milk, can produce, by enzymatic pathway, a CMP-like peptide generally called pseudo-CMP. These two peptides differ from each other only by one amino acid. RP-HPLC and SEC methods are unable to distinguish these two peptides, which demand development of a confirmatory method with high selectivity. Considering the several degrees of glycosilation and phosphorylation sites in CMP, allied with possible genetic variation (CMP A and CMP B), analytical methods able to differentiate these peptides are extremely complex. In the present work, we developed a proteomic-like technique for separation and characterization of these peptides, using liquid chromatography coupled to mass spectrometry with electrospray ionization able to differentiate and subsequently quantify CMP and pseudo-CMP in milk samples in order to identify adulteration or contamination of these products. The method shows satisfactory precision (<11%) with a detection limit of 1.0 µg mL(-1) and quantification limit of 5.0 µg mL(-1). Specificity, matrix effects and applicability to real samples analysis were also performed and discussed. PMID:24468402

  4. Analysis of oak tannins by liquid chromatography-electrospray ionisation mass spectrometry.

    Science.gov (United States)

    Mämmelä, P; Savolainen, H; Lindroos, L; Kangas, J; Vartiainen, T

    2000-09-01

    Extractable tannins were analysed by liquid chromatography-electrospray ionisation mass spectrometry in two oak species, North American white oak (Quercus alba) and European red oak (Quercus robur). They mainly included various glucose gallic and ellagic acid esters. The structures were partially determined, and they included grandinin/roburin E, castalagin/vescalagin, gallic acid, valoneic acid bilactone, monogalloyl glucose, digalloyl glucose, trigalloyl glucose, ellagic acid rhamnose, quercitrin and ellagic acid. PMID:10999626

  5. Evaluation of Offline Tandem and Online Solid-Phase Extraction with Liquid Chromatography/Electrospray Ionization-Mass Spectrometry for Analysis of Antibiotics in Ambient Water and Comparison to an Independent Method

    Science.gov (United States)

    Meyer, M.T.; Lee, E.A.; Ferrell, G.M.; Bumgarner, J.E.; Varns, Jerry

    2007-01-01

    This report describes the performance of an offline tandem solid-phase extraction (SPE) method and an online SPE method that use liquid chromatography/mass spectrometry for the analysis of 23 and 35 antibiotics, respectively, as used in several water-quality surveys conducted since 1999. In the offline tandem SPE method, normalized concentrations for the quinolone, macrolide, and sulfonamide antibiotics in spiked environmental samples averaged from 81 to 139 percent of the expected spiked concentrations. A modified standard-addition technique was developed to improve the quantitation of the tetracycline antibiotics, which had 'apparent' concentrations that ranged from 185 to 1,200 percent of their expected spiked concentrations in matrix-spiked samples. In the online SPE method, normalized concentrations for the quinolone, macrolide, sulfonamide, and tetracycline antibiotics in matrix-spiked samples averaged from 51 to 142 percent of their expected spiked concentrations, and the beta-lactam antibiotics in matrix-spiked samples averaged from 22 to 76 percent of their expected spiked concentration. Comparison of 44 samples analyzed by both the offline tandem SPE and online SPE methods showed 50 to 100 percent agreement in sample detection for overlapping analytes and 68 to 100 percent agreement in a presence-absence comparison for all analytes. The offline tandem and online SPE methods were compared to an independent method that contains two overlapping antibiotic compounds, sulfamethoxazole and trimethoprim, for 96 and 44 environmental samples, respectively. The offline tandem SPE showed 86 and 92 percent agreement in sample detection and 96 and 98 percent agreement in a presence-absence comparison for sulfamethoxazole and trimethoprim, respectively. The online SPE method showed 57 and 56 percent agreement in sample detection and 72 and 91 percent agreement in presence-absence comparison for sulfamethoxazole and trimethoprim, respectively. A linear regression with

  6. Determination of macrolide antibiotics in chicken tissues by liquid chromatography-electrospray mass spectrometry

    Science.gov (United States)

    Salikin, Jamilah; Abdullah, Aminah

    2013-11-01

    A methodusingliquid chromatography-electrospray mass spectrometry (LC-(ESI)MS) for the simultaneous determination of three macrolides (tylosin, spiramycin and tilmicosin) in poultry muscle has been developed. The drugs were extracted with EDTA McIlvaine buffer, filter through celite 545 and the extracts were cleaned up by SPE Oasis HLB cartridge. Separation was carried out in end-capped silica-based C18 column and mobile phases containing trifluoroacetic acid-acetonitrile with a binary gradient system at a flow rate 0.5 ml/min. Detection was performed by single mass spectrometry with electrospray ionization in the positive mode. Several parameters affecting the mass spectra were studied. Chicken samples from the market were analyzed to check the residue of macrolide antibiotics.

  7. Quantitative determination of medroxyprogesterone acetate in plasma by liquid chromatography/electrospray ion trap mass spectrometry.

    Science.gov (United States)

    Kim, S M; Kim, D H

    2001-01-01

    A sensitive and rapid liquid chromatography/electrospray ion trap mass spectrometry (LC/MS/MS) method has been developed for the quantitative determination of medroxyprogesterone acetate (MPA) in human plasma. Plasma samples (1.0 mL) were simply extracted with pentane and the extracts were analyzed by HPLC with the detection of the analyte in the selective reaction monitoring (SRM) mode. The determination of MPA was accurate and reproducible, with a limit of quantitation of 0.05 ng/mL in plasma. The standard calibration curve for MPA was linear (r = 0.998) over the concentration range 0.05-6.0 ng/mL in human plasma. Analysis precision over the concentration range of MPA was lower than 18.8% (relative standard deviation, RSD) and accuracy was between 96.2 and 108.7%. PMID:11675672

  8. Determination of nine sensitizing disperse dyes in activated sludge by ultrasound-assisted liquid-liquid extraction-ultra-performance liquid chromatography-electrospray ionization-tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Linjun; Shi, Lili; Liu, Jining; Lv, Fenglan; Xu, Yanhua

    2016-01-01

    A method was developed on the basis of ultrasound-assisted liquid-liquid extraction ultra-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (ULLE-UPLC-ESI-MS/MS) to determine nine sensitizing disperse dyes in activated sludge. The samples were extracted using ULLE and separated through UPLC on an ACQUITY UPLCTM BEH C18 column with a gradient elution program of acetonitrile and acidified water (containing 2% acetonitrile, 0.2% formic acid, and 0.005 mol/L ammonium; pH 2.7) as the mobile phase. The samples were then identified and quantified through UPLC-ESI-MS/MS in a positive mode and multiple reaction monitoring. Results showed good linearity (10-1000 μg/L, 0.9934-0.9998), detection limit (0.08-2.17 μg/L), and quantification limit (0.27-7.38 μg/L) for the nine sensitizing disperse dyes, with recoveries ranging from 65.0 to 111.3%. The proposed method was applied to detect and determine the concentration of sensitizing disperse dyes in sludge samples obtained from various sewage treatment plants (six dyeing enterprises and one dye manufacturer). Three sensitizing disperse dyes were identified, and the lowest concentration detected was 10 μg/kg. PMID:26521175

  9. The analysis of aqueous mixtures using liquid chromatography-electrospray mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, S.

    1999-02-12

    The focus of this dissertation is the use of chromatographic methods coupled with electrospray mass spectrometry (ES-MS) for the determination of both organic and inorganic compounds in aqueous solutions. The combination of liquid chromatography (LC) methods and ES-MS offers one of the foremost methods for determining compounds in complex aqueous solutions. In this work, LC-ES-MS methods are devised using ion exclusion chromatography, reversed phase chromatography, and ion exchange chromatography, as well as capillary electrophoresis (CE). For an aqueous sample, these LC-ES-MS and CE-ES-MS techniques require no sample preparation or analyte derivatization, which makes it possible to observe a wide variety of analytes as they exist in solution. The majority of this work focuses on the use of LC-ES-MS for the determination of unknown products and intermediates formed during electrochemical incineration (ECI), an experimental waste remediation process. This report contains a general introduction to the project and the general conclusions. Four chapters have been removed for separate processing. Titles are: Chapter 2: Determination of small carboxylic acids by ion exclusion chromatography with electrospray mass spectrometry; Chapter 3: Electrochemical incineration of benzoquinone in aqueous media using a quaternary metal oxide electrode in the absence of a soluble supporting electrolyte; Chapter 4: The determination of electrochemical incineration products of 4-chlorophenol by liquid chromatography-electrospray mass spectrometry; and Chapter 5: Determination of small carboxylic acids by capillary electrophoresis with electrospray mass spectrometry.

  10. Improving detection sensitivity of amino acids in thyroid tissues by using phthalic acid as a mobile phase additive in hydrophilic interaction chromatography-electrospray ionization-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Highlights: • HILIC–ESI-MS/MS method was used to quantify 24 free AAs in human thyroid tissues. • Addition of 0.08 mM of phthalic acid to the eluent enhanced the sensitivity of AAs. • Narrowed peak shapes of AAs were achieved with phthalic acid in the mobile phase. • The mechanism for the signal intensity enhancement by phthalic acid was investigated. - Abstract: In this work, 0.08 mmol L−1 of phthalic acid was introduced as a mobile phase additive to quantify free amino acids (AAs) by hydrophilic interaction liquid chromatography (HILIC) coupled with electrospray ionization tandem mass spectrometry (ESI-MS/MS). The addition of phthalic acid significantly increased the signal intensity of protonated AA ions, resulting from the decrease of the relative abundance of AA sodium adducts. Meanwhile, the chromatographic peak shapes of AAs were optimized. As a consequence, there was a noticeable increase in the sensitivity of detection for AAs. The limits of detection (LOD) and quantification (LOQ) of the AAs ranged from 0.0500 to 20.0 ng mL−1 and from 0.100 to 50.0 ng mL−1, respectively, which were 4–50 times lower compared to the values measured without the addition of phthalic acid. The enhanced detection and separation of AAs were obtained by merely adding phthalic acid to the mobile phase without changing other conditions. Eventually, this simple method was validated and successfully applied to the analysis of twenty-four kinds of free AAs in human thyroid carcinoma and para-carcinoma tissues, demonstrating a significant increase of most AAs in thyroid carcinoma tissues (p < 0.05)

  11. Improving detection sensitivity of amino acids in thyroid tissues by using phthalic acid as a mobile phase additive in hydrophilic interaction chromatography-electrospray ionization-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Wanshu [National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032 (China); Guan, Qing [Department of Head and Neck Surgery, Fudan University Shanghai Cancer Center (FUSCC), Shanghai 200032 (China); Department of Oncology, Shanghai Medical College, Fudan University, Shanghai 200032 (China); Sun, Tuanqi, E-mail: tuanqisun@163.com [Department of Head and Neck Surgery, Fudan University Shanghai Cancer Center (FUSCC), Shanghai 200032 (China); Department of Oncology, Shanghai Medical College, Fudan University, Shanghai 200032 (China); Cao, Yanjing [National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032 (China); Zhang, Li, E-mail: zhangli7488@sioc.ac.cn [National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032 (China); Guo, Yinlong, E-mail: ylguo@sioc.ac.cn [National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032 (China)

    2015-04-22

    Highlights: • HILIC–ESI-MS/MS method was used to quantify 24 free AAs in human thyroid tissues. • Addition of 0.08 mM of phthalic acid to the eluent enhanced the sensitivity of AAs. • Narrowed peak shapes of AAs were achieved with phthalic acid in the mobile phase. • The mechanism for the signal intensity enhancement by phthalic acid was investigated. - Abstract: In this work, 0.08 mmol L{sup −1} of phthalic acid was introduced as a mobile phase additive to quantify free amino acids (AAs) by hydrophilic interaction liquid chromatography (HILIC) coupled with electrospray ionization tandem mass spectrometry (ESI-MS/MS). The addition of phthalic acid significantly increased the signal intensity of protonated AA ions, resulting from the decrease of the relative abundance of AA sodium adducts. Meanwhile, the chromatographic peak shapes of AAs were optimized. As a consequence, there was a noticeable increase in the sensitivity of detection for AAs. The limits of detection (LOD) and quantification (LOQ) of the AAs ranged from 0.0500 to 20.0 ng mL{sup −1} and from 0.100 to 50.0 ng mL{sup −1}, respectively, which were 4–50 times lower compared to the values measured without the addition of phthalic acid. The enhanced detection and separation of AAs were obtained by merely adding phthalic acid to the mobile phase without changing other conditions. Eventually, this simple method was validated and successfully applied to the analysis of twenty-four kinds of free AAs in human thyroid carcinoma and para-carcinoma tissues, demonstrating a significant increase of most AAs in thyroid carcinoma tissues (p < 0.05)

  12. Highly sensitive isotope-dilution liquid-chromatography-electrospray ionization-tandem-mass spectrometry approach to study the drug-mediated modulation of dopamine and serotonin levels in Caenorhabditis elegans.

    Science.gov (United States)

    Schumacher, Fabian; Chakraborty, Sudipta; Kleuser, Burkhard; Gulbins, Erich; Schwerdtle, Tanja; Aschner, Michael; Bornhorst, Julia

    2015-11-01

    Dopamine (DA) and serotonin (SRT) are monoamine neurotransmitters that play a key role in regulating the central and peripheral nervous system. Their impaired metabolism has been implicated in several neurological disorders, such as Parkinson's disease and depression. Consequently, it is imperative to monitor changes in levels of these low-abundant neurotransmitters and their role in mediating disease. For the first time, a rapid, specific and sensitive isotope-dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of DA and SRT in the nematode Caenorhabditis elegans (C. elegans). This model organism offers a unique approach for studying the effect of various drugs and environmental conditions on neurotransmitter levels, given by the conserved DA and SRT biology, including synaptic release, trafficking and formation. We introduce a novel sample preparation protocol incorporating the usage of sodium thiosulfate in perchloric acid as extraction medium that assures high recovery of the relatively unstable neurotransmitters monitored. Moreover, the use of both deuterated internal standards and the multiple reaction monitoring (MRM) technique allows for unequivocal quantification. Thereby, to the best of our knowledge, we achieve a detection sensitivity that clearly exceeds those of published DA and SRT quantification methods in various matrices. We are the first to show that exposure of C. elegans to the monoamine oxidase B (MAO-B) inhibitor selegiline or the catechol-O-methyltransferase (COMT) inhibitor tolcapone, in order to block DA and SRT degradation, resulted in accumulation of the respective neurotransmitter. Assessment of a behavioral output of the dopaminergic system (basal slowing response) corroborated the analytical LC-MS/MS data. Thus, utilization of the C. elegans model system in conjunction with our analytical method is well-suited to investigate drug-mediated modulation of the DA and

  13. Determination of Tetracyclin, Oxytetracycline and Roxithromycin in Water Samples by Solid Phase Extraction-Ultra Performance Liquid Chromatography Electrospray Tandem Mass Spectrometry%固相萃取-超高效液相色谱三重四级杆质谱联用法测定水中四环素、土霉素及罗红霉素

    Institute of Scientific and Technical Information of China (English)

    尹燕敏

    2013-01-01

    A rapid analytical method for simultaneous determination of tetracyclin, oxytetracycline and roxithromycin in water sample was developed. Water samples were purified and concentrated by solid phase extraction(SPE), then analyzed by ultra performance liquid chromatography electrospray tandem mass spectrometry(UPLC-MS/MS). Using formic acid and acetonitrile as the mobile phase, the three antibiotics were separated within 5 min. The limit of determination for anlytes were 0.08-0.35 ng/L with the relative standard deviation of 1.4%-5.6%. The recoveries of the antibiotics were in the range of 82.5%-114%for blank and 71.5%-126%for real samples.%建立了固相萃取-超高效液相色谱三重四级杆质谱联用法同时测定水中的罗红霉素、四环素和土霉素残留。水样经过固相萃取纯化、富集,液质联用分析,采用甲酸溶液和乙腈作为流动相,在5 min内完成对3种目标化合物的分析,3种目标化合物的方法检出限介于0.08~0.35 ng/L之间,测定结果的相对标准偏差为1.4%~5.6%,空白样品和实际样品的加标回收率分别为82.5%~114%,71.5%~126%。

  14. Determination of palonosetron in human plasma by liquid chromatography-electrospray ionization-mass spectrometry.

    Science.gov (United States)

    Ding, Li; Chen, Yan; Yang, Lin; Wen, Aidong

    2007-06-28

    A high performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS) method for the determination of palonosetron (PALO) in human plasma using naloxone as the internal standard (IS) was established. After adjustment to a weakly basic pH with saturated sodium bicarbonate, plasma samples were extracted with ethyl acetate and separated on a Hanbon Lichrospher 5-C18 column with a mobile phase of 40 mM ammonium acetate buffer solution containing 0.04% formic acid-methanol (46:54, v/v). PALO was determined with electrospray ionization-mass spectrometry (ESI-MS). HPLC-ESI-MS was performed in the selected-ion monitoring (SIM) mode using target ions at [M+H]+ m/z 297.2 for PALO and [M+H]+ m/z 328.2 for the IS. Calibration curve was linear over the range of 0.02124-10.62 ng/ml. The lower limit of quantification (LLOQ) was 0.02124 ng/ml. The intra- and inter-run variability values were all less than 10.4%. The method has been successfully applied to determine the plasma concentration of PALO in healthy Chinese volunteers. PMID:17127028

  15. Are liquid chromatography/electrospray tandem quadrupole fragmentation ratios unequivocal confirmation criteria?

    Science.gov (United States)

    Kaufmann, Anton; Butcher, Patrick; Maden, Kathryn; Widmer, Mirjam; Giles, Kevin; Uría, Diana

    2009-04-01

    Multiple reaction monitoring (MRM) ratios as provided by tandem mass spectrometers are used to confirm positive residue findings (e.g. veterinary drugs or pesticides). The Commission Decision 2002/657/EEC defines tolerance levels for MRM ratios, which are intended to prevent the reporting of false positives. This paper reports findings where blank sample extracts have been spiked by a drug (difloxacin) and the corresponding measured MRM ratios significantly deviated from MRM ratios observed in matrix-free solution. The observation was explained by the formation of two different [M+H](+) analyte ions within the electrospray ionization (ESI) interface. These two ions vary only by the site of analyte protonation. Since they are isobaric, they are equally transmitted through the first quadrupole, but are differently fragmented in the collision chamber. The existence of two isobaric ions was deduced by statistical data and the observation of a doubly charged analyte ion. It was hypothesized that the combined presence of [M+H](+) and [M+2H](2+) implies the existence of two different singly charged ion species differing only by the site of protonation. Low- and high-energy interface-induced fragmentation was performed on the samples. The surviving precursor ion population was mass selected and again fragmented in the collision chamber. Equal product ion spectra would be expected. However, very different product ion spectra were observed for the two interface regimes. This is consistent with the assumption that the two postulated isobaric precursor ions show different stability in the interface. Hence the abundance ratio among the two types of surviving precursor ions will shift and change the resulting product ion spectra. The existence of the postulated singly charged ions with multiple chargeable sites was finally confirmed by successful ion mobility separation. PMID:19241450

  16. Validation of a Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry Method for Determination of All-Trans Retinoic Acid in Human Plasma and Its Application to a Bioequivalence Study

    Directory of Open Access Journals (Sweden)

    Jing-Bo Peng

    2014-01-01

    Full Text Available A sensitive, reliable and specific LC-MS-MS method was developed and validated for the identification and quantitation of all-trans retinoic acid (ATRA in human plasma. Acitretin was used as the internal standard (IS. After liquid-liquid extraction of 500 μL plasma with methyl tert-butyl ether (MTBE, ATRA and the IS were chromatographed on a HyPURITY C18 column (150 mm × 2.1 mm, 5 μm with the column temperature set at 40 °C. The mobile phase was consisted of 40% phase A (MTBE–methanol–acetic acid, 50:50:0.5, v/v and 60% phase B (water–methanol–acetic acid, 50:50:0.5, v/v with a flow rate of 0.3 mL/min. The API 4000 triple quadrupole mass spectrometer was operated in multiple reaction monitoring (MRM mode via the positive electrospray ionization interface using the transition m/z 301.4 → 123.1 for ATRA and m/z 326.9 → 177.1 for IS, respectively. The calibration curve was linear over the range of 0.45–217.00 ng/mL (r ≥ 0.999 with a lower limit of quantitation (LLOQ of 0.45 ng/mL. The intra- and inter-day precisions values were below 8% relative standard deviation and the accuracy was from 98.98% to 106.19% in terms of relative error. The validated method was successfully applied in a bioequivalence study of ATRA in Chinese healthy volunteers.

  17. A simplified procedure for the analysis of formoterol in human urine by liquid chromatography-electrospray tandem mass spectrometry: application to the characterization of the metabolic profile and stability of formoterol in urine.

    Science.gov (United States)

    Mazzarino, Monica; de la Torre, Xavier; Fiacco, Ilaria; Pompei, Chiara; Calabrese, Fabiana; Botrè, Francesco

    2013-07-15

    Since 1992, formoterol is included in the prohibited list of doping substances and methods, presently reviewed and updated by the World Anti-Doping Agency. Recently a threshold value of 40ng/mL has been established to differentiate between the prohibited (oral) and the permitted (inhalatory) administration of formoterol to athletes. This paper considers the urinary excretion profile of formoterol and its main metabolites after inhalation of different doses of two of the most used medicaments, available in Italy, containing formoterol fumarate bihydrate (12 and 36μg twice a day of Foradil(®) or 9 and 27μg twice a day of Symbicort(®)), focusing also on the effects, on the measured levels of formoterol, of potential alteration processes (thermal and/or microbiological) that may take place after the collection of the urine samples. Urine sample preparation included an enzymatic hydrolysis and a dilution step. Detection of analytes was performed by a newly developed and validated direct LC-ESI-MS/MS procedure, using a triple quadrupole mass spectrometer under positive ion electro-spray ionization conditions and selected reaction monitoring acquisition mode. The results showed the capability and suitability of the direct LC-ESI-MS/MS analysis for the quantitative confirmation analysis of formoterol in urine samples. The data from the analysis of the urine samples obtained in the excretion studies showed that formoterol is excreted mainly as unmodified drug and to a lesser degree as O-demethylated metabolite. The urinary levels of formoterol (40-60%) and its metabolites (O-demethylated metabolite 5-25%; glucuronide metabolites 25-40%) vary significantly depending both on the administered drug formulation and the subject tested. The maximum urinary concentration reached in this study was 15ng/mL (free+glucuronide), that is significantly lower than the threshold value fixed to report an adverse analytical finding. Finally, our results also showed that formoterol is

  18. 固相萃取-超高效液相色谱-电喷雾串联质谱法检测梨树叶中熊果苷%Quantitative and qualitative determination of arbutin in pear leaves by ultra performance liquid chromatography-electrospray tandem mass spectrometry coupled with solid phase extraction

    Institute of Scientific and Technical Information of China (English)

    赵洁; 何强; 孔祥虹; 李建华; 乐爱山; 姚秉华

    2011-01-01

    建立了固相萃取净化、超高效液相色谱-串联质谱检测梨树叶中熊果苷含量的方法.将粉碎的梨树叶样品用甲醇提取,ENVITM-18固相萃取柱净化,超高效液相-电喷雾串联四级杆质谱检测,外标法定量.测定时用 Acquity UPLC HSS T3 色谱柱(50 mm×2.1 mm,1.8μm)分离,甲醇-水(V/V,7+93)洗脱,多重反应监测 (MRM) 模式检测,定量离子对为m/z 271.2>107.8,定性离子对为 m/z 271.2>160.9.熊果苷的最低检出限为 0.05μg/mL,在0.1~10.0μg/mL 的范围内标准溶液的峰面积与浓度呈良好的线性关系,回收率为93.2%~106.5%,相对标准偏差低于5.9%.%An ultra performance liquid chromatography-electrospray tandem mass spectrometries (UPLC-ESI-MS/MS) method was developed for the quantitative and qualitative determination of arbutin in pear leaves. The full powdered pear leaves were extracted with methanol and purified by ENVITM-18 SPE columns. Analysis was performed on UPLC-ESI-MS/MS and quantitation was carried out using an external standard method. Separation of the samples was performed on an acquity UPLC HSS T3 column (50 mm × 2. 1 mm, 1.8 μm) using methanolwater(V/V, 7 + 93 ) as mobile phase. MS/MS was performed with multiple reaction monitoring (MRM) mode using m/z 271.2 > 107. 8 as quantitative ion pair and m/z 271.2 > 160. 9 as qualitative ion pair. The detection limit of arbutin was 0. 05 μg/mL. The method showed good linear relationship in the range of 0. 1 ~ 10. 0 μg/mL.

  19. 超高效液相色谱-电喷雾串联质谱法测定塑料成品中的三甲基氯化锡%Determination of trimethyltin in plastic product by using ultra high performance liquid chromatography electrospray ionization tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    陈慧玲; 许欣欣; 毛丽莎; 刘红河; 陆少游

    2016-01-01

    目的:建立塑料成品中三甲基氯化锡(TMT)的超高效液相色谱-串联质谱联用测定法(UPLC-MS/MS)。方法塑料样品用乙酸乙酯提取,洗脱液在40℃水浴下氮气吹干;残渣用流动相溶解,旋涡混匀60s,过0.22μm微孔滤膜,经C18色谱柱完成分离,串联质谱仪上采用多反应监测正离子模式测定三甲基氯化锡,外标法定量。结果三甲基氯化锡在1.0~100.0μg/L 范围内线性关系良好(相关系数 r=0.9997),检出限0.2μg/L。在2.0、10.0和50.0μg/L 3个添加水平范围的RSD小于8.0%,样品加标回收率为88.5%~93.4%。结论建立的超高效液相色谱-串联质谱联用法测定塑料成品中三甲基氯化锡的方法快速简单、准确有效。%Objective An ultra-high performance liquid chromatography eclectrospray ionization tandem mass spectrometry (UPLC-MS/MS) method was developed to determine trimethyltin (TMT) in plastic product. Methods TMT was extracted from plastic product by ethyl acetate, the elute was evaporated to dryness with nitrogen in 40℃ water bath, redissolved with 1ml of moble phase solution, vortexed for 60 s and filtered with 0.22 μm membrane. The filtrate was detected by UPLC-MS/MS in positive ion electrospray and MRM mode with a UPLC C18 column as separation column, and quantified with external standard substances. Results TMT was linear in the range of 1.0~100.0 μg/L with correlation coefficient of 0.9997. The relative standard derivations (RSD) at three levels (2.0 μg/L、10.0 μg/L and 50.0 μg/L) were lower than 8.0%, and the recovery rate was from 88.5% to 93.4%. Conclusion The method of liquid chromatography-electrospray tandem mass spectrometry is simple, reliable and accurate, that adapts to determinate TMT in plastic product.

  20. 液相色谱-串联质谱法测定河豚鱼和鳗鱼中9种青霉素类抗生素%Determination of 9 penicillins in Fugu and eel by high pressure liquid chromatography-electrospray tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    李学民; 曹彦忠; 张进杰; 母健; 王蕾; 王贺琴

    2013-01-01

      目的建立高压液相色谱-电喷雾串联质谱(HPLC-MS-MS)同时测定河豚鱼和鳗鱼中9种青霉素残留量的检测方法。方法样品经乙腈-氨水溶液提取后,用C18色谱柱分离,乙腈-乙酸为流动相梯度洗脱,最后采用液相色谱-电喷雾串联质谱在正离子多反应监测模式下测定。结果在1.0~20μg/kg(LOQ~10LOQ)范围时,方法线性关系良好,相关系数大于0.999。在LOQ、2 LOQ、4 LOQ、10 LOQ四个添加水平下青霉素的回收率在81.4%~109.7%之间,相对标准偏差在2.81%~7.12%之间,方法检出限是:萘夫西林、青霉素 G、哌拉西林、青霉素 V、苯唑西林为1.0μg/kg;阿莫西林、氨苄西林、氯唑西林、双氯西林为2.0μg/kg。结论此方法灵敏度高,准确性好,适用于水产品中青霉素的定量检测。%Objective A sensitive method was developed for the determination of 9 penicillins in Fugu and eel by high pressure liquid chromatography-electrospray tandem mass spectrometry (HPLC-MS/MS). Methods Samples were extracted with acetonitrile-ammonia water, separated on a C18 column by gradient elution with acetonitrile and 0.3%acetic acid solution as mobile phase. Identification was achieved by electro-spray ionization(ESI) in positive mode. Results The method showed a good linearity over the range of 1.0~20μg/kg for 9 compounds of penicillins with r≥0.999. Recoveries of 9 penicillins were between 81.4% and 109.7% (n=6) at spiked levels of LOQ, 2LOQ, 4LOQ and 10LOQ with relative standard deviations (RSD of 2.81%∼7.12%). The limit of quantitation(LOQ) for nafcillin, penicillin G, piperacillin, penicillin V and oxacil-lin were 1.0 μg/kg and the LOQ for amoxicillin, ampicillin, cloxacillin and dicloxacillin were 2.0 μg/kg. Conclusion This method is sensitive and accurate, and it is suitable for the analysis of 9 penicillins in aquatic products.

  1. Liquid Chromatography-Electrospray Ionization Mass Spectrometry Method for the Rapid Identification of Citrus Limonoid Glucosides in Citrus Juices and Extracts

    Science.gov (United States)

    A rapid and selective liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method to screen citrus samples for limonoid glucosides and estimate their relative concentrations has been developed. This method utilizes a phenyl stationary phase, whereas previous methods have reli...

  2. Identification of Phenylethanoid Glycosides in Plant Extract of Plantago asiatica L. by Liquid Chromatography-Electrospray Ionization Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    LI,Li; LIU,Chunming; LIU,Zhiqiang; TSAO,Rong; LIU,Shuying

    2009-01-01

    The present work describes a liquid chromatography-electrospray ionization mass spectrometry(LC-ESI-MS)method for rapid identification of phenylethanoid glycosides in plant extract from Plnmgo asiatica L.By using a binary mobile phase system consisting of 0.2% acetic acid and acetonitrile under gradient conditions,a good sepa-ration was achieved on a reversed-phase C18 column.The[M-H] ions,the molecular weights,and the fragmentions of phenvlethanoid glycosides were obtained in the negative ion mode using LC-ESI-MS.The identification of the phenylethanoid glycosides(peaks 1-3) in the extract of P. asiatica L.was based on matching their retention time.the detection of molecular ions.and the fragment ions obtained by collision-induced dissociation(CID)ex-periments with those of the authentic standards and data reported in the literature.

  3. Enantiomeric quantification of (S)-(+)-methamphetamine in urine by an immunoaffinity column and liquid chromatography-electrospray-mass spectrometry

    International Nuclear Information System (INIS)

    A method using an immunoaffinity column (IAC) and liquid chromatography-electrospray ionization mass spectrometry (LC/MS) for on-line detecting the presence of MA in the effluent was developed for the quantitative and enantiomeric determination of (S)-(+)-methamphetamine (D-MA) in urine. The IAC was made in our laboratory and utilized in the LC/MS to simultaneously extract and separate enantiomers of MA from urine samples. An aqueous ammonium acetate buffer was used as the mobile phase. Urine samples were spiked with racemic deuterated methamphetamine (MA-d14) as internal standard (IS), filtered through a membrane, and injected into the LC/MS without any further pre-treatment. Protonated molecular ion of MA and MA-d14 (m/z 150 and 164) were isolated and further fragmented, the respective product ions, m/z 119 and 130, were collected for quantitative determination. This is an improvement of our previous method (A.C. Lua, Tsong-Yung Chou, J. Chromatogr. A 967 (2002) 191). In the previous method, MA was separated with HPLC, the efflux was fractionated and each fraction was either determined with an immunoassay or GC/MS. Monitoring of MA in the efflux is tedious and time consuming. Urine samples spiked with different concentrations of D-MA were measured by this method. A linear relationship exists in the 150-1050 ng/mL range, and the detection limit (defined as signal-to-noise ratio 3) of D-MA was determined to be 18 ng/mL. The linearity of the method for D-MA can be described by the equation (Y = 1.415 x 10-3 X + 0.034, correlation coefficient: r 2 = 0.999). Within run, accuracy and precision (n = 6, relative error: -7.2 to +4.0% and relative standard deviation: 3.8-9.3%) of the method are fairly good

  4. Tools to discover anionic and nonionic polyfluorinated alkyl surfactants by liquid chromatography electrospray ionisation mass spectrometry

    DEFF Research Database (Denmark)

    Trier, Xenia; Granby, Kit; Christensen, Jan H.

    2011-01-01

    A tiered approach is proposed for the discovery of unknown anionic and nonionic polyfluorinated alkyl surfactants (PFASs) by reversed phase ultra high performance liquid chromatography (UHPLC) – negative electrospray ionisation – quadrupole time of flight mass spectrometry (UHPLC–ESI−–QTOF–MS). T.......g., structural PFAS isomers. The method has been used to discover PFASs in industrial blends and in extracts from food contact materials....

  5. Quantitative determination of capsaicinoids by liquid chromatography-electrospray mass spectrometry.

    Science.gov (United States)

    Thompson, Robert Q; Phinney, Karen W; Welch, Michael J; White, Edward

    2005-04-01

    Eight naturally occurring capsaicinoids have been determined in Capsicum by use of high-purity standards, with norcapsaicin as an internal standard. The solid standards were rigorously checked for purity. The sensitivity of electrospray ionization (ESI), atmospheric-pressure chemical ionization (APCI), and coordination ion-spray (CIS; with silver) toward the capsaicinoids were measured and compared. The highest sensitivity was found for positive-ion ESI. Method validation of the liquid chromatography-ESI-mass spectrometry (LC-ESI-MS) determination is reported, including tests for repeatability (4%), detection limit (5 pg injected), linear range (20-6 ng injected), quantitation (excellent linearity; pepper fruits were quantified. PMID:15803309

  6. Determination of synthetic ferric chelates used as fertilizers by liquid chromatography-electrospray/mass spectrometry in agricultural matrices.

    Science.gov (United States)

    Alvarez-Fernández, Ana; Orera, Irene; Abadía, Javier; Abadía, Anunciación

    2007-01-01

    A high-performance liquid chromatography-electrospray ionization/mass spectrometry (time of flight) method has been developed for the simultaneous determination of synthetic Fe(III)-chelates used as fertilizers. Analytes included the seven major Fe(III)-chelates used in agriculture, Fe(III)-EDTA, Fe(III)-DTPA, Fe(III)-HEDTA, Fe(III)-CDTA, Fe(III)-o,oEDDHA, Fe(III)-o,pEDDHA, and Fe(III)-EDDHMA, and the method was validated using isotope labeled (57)Fe(III)-chelates as internal standards. Calibration curves had R values in the range 0.9962-0.9997. Limits of detection and quantification were in the ranges 3-164 and 14-945 pmol, respectively. Analyte concentrations could be determined between the limits of quantification and 25 muM (racemic and meso Fe(III)-o,oEDDHA and Fe(III)-EDDHMA) or 50 muM (Fe(III)-EDTA, Fe(III)-HEDTA, Fe(III)-DTPA, Fe(III)-CDTA and Fe(III)-o,pEDDHA). The average intraday repeatability values were approximately 0.5 and 5% for retention time and peak area, respectively, whereas the interday repeatability values were approximately 0.7 and 8% for retention time and peak area, respectively. The method was validated using four different agricultural matrices, including nutrient solution, irrigation water, soil solution, and plant xylem exudates, spiked with Fe(III)-chelate standards and their stable isotope-labeled corresponding chelates. Analyte recoveries found were in the ranges 92-101% (nutrient solution), 89-102% (irrigation water), 82-100% (soil solution), and 70-111% (plant xylem exudates). Recoveries depended on the analyte, with Fe(III)-EDTA and Fe(III)-DTPA showing the lowest recoveries (average values of 87 and 88%, respectively, for all agricultural matrices used), whereas for other analytes recoveries were between 91 and 101%. The method was also used to determine the real concentrations of Fe(III)-chelates in commercial fertilizers. Furthermore, the method is also capable of resolving two more synthetic Fe(III)-chelates, Fe

  7. Determination of flavone, flavonol, and flavanone aglycones by negative ion liquid chromatography electrospray ion trap mass spectrometry

    OpenAIRE

    Fabre, Nicolas; Rustan, Isabelle; de Hoffmann, Edmond; Quetin-Leclercq, Joëlle

    2001-01-01

    Eleven naturally occurring flavonoid aglycones, belonging to the representative flavone, flavonol, and flavanone types were separated by high performance liquid chromatography and analyzed on-line with negative ion electrospray ionization tandem mass spectrometry (ESI-MS/MS). In order to resolve the MS/MS spectra obtained, each compound was reinvestigated by direct loop injections using an ion trap mass spectrometer. The MSn spectra obtained allowed us to propose plausible schemes for their f...

  8. Identification of 3',4'-Dimethoxy Flavonol-3-β-d-Glucopyranoside Metabolites in Rats by Liquid Chromatography-Electrospray Ionization Ion Trap Mass Spectrometry.

    Science.gov (United States)

    Zhu, Yuan; Wen, Jun; Cao, Yuqing; Jiang, Yuanying; Huang, Jinghua; Fan, Guorong; Lou, Yuefen

    2016-01-01

    A method using liquid chromatography-electrospray ionization ion trap mass spectrometry was established for the identification of metabolites in feces, urine and bile in rats after oral administration of 3',4'-dimethoxy flavonol-3-β-d-glucopyranoside (abbreviated DF3G). Seven metabolites in rat feces, urine and bile were firstly identified on the basis of their MS fragmentation behaviors. Three metabolites were identified in the feces, 6 in the urine and 2 in the bile, which suggested that demethylation, deglycosylation and deglycosylation followed by glucuronide conjugation were the major metabolic pathways for DF3G in vivo. Hydrolyzation might be the first step in the absorption and metabolism of DF3G. The possible metabolic pathway was proposed for the first time. The established method was simple, reliable and sensitive, revealing that it could be used to rapidly screen and identify the structures of metabolites of DF3G to better understand its metabolism in vivo. PMID:27070571

  9. Retention behavior of lipids in reversed-phase ultrahigh-performance liquid chromatography-electrospray ionization mass spectrometry.

    Science.gov (United States)

    Ovčačíková, Magdaléna; Lísa, Miroslav; Cífková, Eva; Holčapek, Michal

    2016-06-10

    Reversed-phase ultrahigh-performance liquid chromatography (RP-UHPLC) method using two 15cm sub-2μm particles octadecylsilica gel columns is developed with the goal to separate and unambiguously identify a large number of lipid species in biological samples. The identification is performed by the coupling with high-resolution tandem mass spectrometry (MS/MS) using quadrupole - time-of-flight (QTOF) instrument. Electrospray ionization (ESI) full scan and tandem mass spectra are measured in both polarity modes with the mass accuracy better than 5ppm, which provides a high confidence of lipid identification. Over 400 lipid species covering 14 polar and nonpolar lipid classes from 5 lipid categories are identified in total lipid extracts of human plasma, human urine and porcine brain. The general dependences of relative retention times on relative carbon number or relative double bond number are constructed and fit with the second degree polynomial regression. The regular retention patterns in homologous lipid series provide additional identification point for UHPLC/MS lipidomic analysis, which increases the confidence of lipid identification. The reprocessing of previously published data by our and other groups measured in the RP mode and ultrahigh-performance supercritical fluid chromatography on the silica column shows more generic applicability of the polynomial regression for the description of retention behavior and the prediction of retention times. The novelty of this work is the characterization of general trends in the retention behavior of lipids within logical series with constant fatty acyl length or double bond number, which may be used as an additional criterion to increase the confidence of lipid identification. PMID:27179677

  10. Metabolic profile of naringenin in the stomach and colon using liquid chromatography/electrospray ionization linear ion trap quadrupole-Orbitrap-mass spectrometry (LC-ESI-LTQ-Orbitrap-MS) and LC-ESI-MS/MS.

    Science.gov (United States)

    Orrego-Lagarón, Naiara; Vallverdú-Queralt, Anna; Martínez-Huélamo, Miriam; Lamuela-Raventos, Rosa M; Escribano-Ferrer, Elvira

    2016-02-20

    Several biological activities (antioxidant, anti-inflammatory, anticarcinogenic) are attributed to naringenin (NAR)-a predominant flavonoid of citrus fruit and tomato-despite its low bioavailability after ingestion. NAR undergoes extensive metabolism when crossing the gastrointestinal tract, resulting in enteric, hepatic and microbial metabolites, some of them with recognized beneficial effects on human health. This study sought to provide new insights into the metabolism of NAR in regions of the gastrointestinal tract where it has been less studied: the stomach and colon. With this purpose, liquid chromatography coupled with an electrospray ionization hybrid linear ion trap quadrupole Orbitrap mass spectrometry technique (LC-ESI-LTQ-Orbitrap-MS) was used for an accurate identification of NAR metabolites, and liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) on a triple quadrupole was used for their identification and quantification. The combination of both analytical techniques provided a broader metabolic profile of NAR. As far as we know, this is the first in-depth metabolic profiling study of NAR in the stomach of mice. Three of the metabolites determined using the LC-LTQ-Orbitrap could not be identified by LC-ESI-MS/MS in stomach perfusion samples: apigenin, 3-(4-hydroxyphenyl) propionic acid and phloroglucinol. The number of colonic metabolites determined using the LTQ-Orbitrap-MS was more than twice the number identified by LC-ESI-MS/MS. PMID:26698229

  11. Separation of small molecular peptides with the same amino acid composition but different sequences by high performance liquid chromatography-electrospray ionization-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Peptidomics has emerged as a new discipline in recent years. Mass spectrometry (MS) is the most universal and efficient tool for structure identification of proteins and peptides. However,there is a limitation for the identification of peptides with the same amino acid composition but different se-quences because these peptides have identical mass spectra of molecular ions. This paper presents a high performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS) method for the separation of small molecular peptides with the same amino acid composition but dif-ferent sequences. Two tripeptides of Gly-Ser-Phe and Gly-Phe-Ser were used as a model sample. The separation behavior has been investigated and the separation conditions have been optimized. Under the optimum conditions,good repeatability was achieved. The developed method could provide a helpful reference for the separation of other peptides with the same amino acid composition but different sequences in the study of proteomics and peptidomics.

  12. Quantification of voriconazole in human plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry: application to a bioequivalence study.

    Science.gov (United States)

    Cheng, Ying; Zhang, Zun-Jian; Tian, Yuan; Li, Wen-Jing; Wei, Wei

    2011-01-01

    A sensitive and specific liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method was developed and validated for the identification and quantification of voriconazole (VRC, CAS 137234-62-9) in human plasma. Following liquid-liquid extraction, VRC and loratadine (internal standard, CAS 79794-75-5) were separated using a mobile phase comprised of methanol: water (0.1% formic acid) = 75:25 v/v on a Shimadzu Shim-pack VP-ODS C18 (150 x 2.0 mm ID, 5 microm) column and analyzed by electrospray ionization mass spectrometry. The chromatographic separation was achieved in less than 6 min. The standard curves were linear (r = 0.9994) over the concentration range of 2-2000 ng/mL for VRC and had good accuracy and precision. Both intra- and inter-batch standard deviations were less than 15%. The method was successfully applied to study the comparative bioavailability of VRC tablets test vs. reference in healthy Chinese volunteers through the statistical comparison of pharmacokinetic parameters obtained with the two formulations. PMID:21428249

  13. Identification of 3′,4′-Dimethoxy Flavonol-3-β-d-Glucopyranoside Metabolites in Rats by Liquid Chromatography-Electrospray Ionization Ion Trap Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Yuan Zhu

    2016-04-01

    Full Text Available A method using liquid chromatography-electrospray ionization ion trap mass spectrometry was established for the identification of metabolites in feces, urine and bile in rats after oral administration of 3′,4′-dimethoxy flavonol-3-β-d-glucopyranoside (abbreviated DF3G. Seven metabolites in rat feces, urine and bile were firstly identified on the basis of their MS fragmentation behaviors. Three metabolites were identified in the feces, 6 in the urine and 2 in the bile, which suggested that demethylation, deglycosylation and deglycosylation followed by glucuronide conjugation were the major metabolic pathways for DF3G in vivo. Hydrolyzation might be the first step in the absorption and metabolism of DF3G. The possible metabolic pathway was proposed for the first time. The established method was simple, reliable and sensitive, revealing that it could be used to rapidly screen and identify the structures of metabolites of DF3G to better understand its metabolism in vivo.

  14. Analysis of ribo- and deoxyribonucleic acids using ionpair-reversed-phase liquid-chromatography electrospray-mass spectrometry

    International Nuclear Information System (INIS)

    The fast progress in natural sciences like biology, biochemistry, medicine or genetics make high demands on the analytical chemistry. The on-line coupling of ionpair-reversed phase-liquid chromatography (IP-RP-HPLC) to mass spectrometry (MS) becomes more and more the method of choice for the analysis of biomolecules. The success is based on the introduction of soft ionization methods, like electrospray ionization (ESI), which allows the transfer of intact biopolymers into the gasphase. This combination enables the on-line separation of complex biological mixtures with additional identification of the compounds by their molecular mass. The first part describes the development of a new ionsource, which combines the advantages of a micro-ESI- and a nanospray-source. In combination with additional optimization of the chromatographic conditions the new ionsource showed an improvement of the quality of the spectra by a factor of 5 and a stability of the ionspray by a factor of 2, which resulted in an overall improvement of sensitivity by a factor of 10 for the HPLC-MS system. The second part describes the quality control of synthetic RNA molecules. Using IP-RP-HPLC-ESI-MS it was possible to separate failure sequences and derivatives in raw products of short synthetic RNAs. The derivatives were formed of protecting groups, which were not removed during the deprotection step. The analysis of coupling products of the synthesis of aminoacylated transfer RNAs showed a derivative, which was formed by the addition of the used coupling reagent N-(3-dimethylaminopropyl)N'-ethylcarbodiimide (EDC). The identification of the derivatives led to the optimization of the reaction conditions which resulted in the synthesis of the wanted transfer RNA without any additional derivatives. Another experiment involved the fragmentation of RNA molecules. Tandem mass spectrometry provides the opportunity to determine the sequence of nucleic acids. Fragmentation experiments showed different

  15. Development of a method for comprehensive and quantitative analysis of plant hormones by highly sensitive nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry

    International Nuclear Information System (INIS)

    In recent plant hormone research, there is an increased demand for a highly sensitive and comprehensive analytical approach to elucidate the hormonal signaling networks, functions, and dynamics. We have demonstrated the high sensitivity of a comprehensive and quantitative analytical method developed with nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry (LC-ESI-IT-MS/MS) under multiple-reaction monitoring (MRM) in plant hormone profiling. Unlabeled and deuterium-labeled isotopomers of four classes of plant hormones and their derivatives, auxins, cytokinins (CK), abscisic acid (ABA), and gibberellins (GA), were analyzed by this method. The optimized nanoflow-LC-ESI-IT-MS/MS method showed ca. 5-10-fold greater sensitivity than capillary-LC-ESI-IT-MS/MS, and the detection limits (S/N = 3) of several plant hormones were in the sub-fmol range. The results showed excellent linearity (R2 values of 0.9937-1.0000) and reproducibility of elution times (relative standard deviations, RSDs, <1.1%) and peak areas (RSDs, <10.7%) for all target compounds. Further, sample purification using Oasis HLB and Oasis MCX cartridges significantly decreased the ion-suppressing effects of biological matrix as compared to the purification using only Oasis HLB cartridge. The optimized nanoflow-LC-ESI-IT-MS/MS method was successfully used to analyze endogenous plant hormones in Arabidopsis and tobacco samples. The samples used in this analysis were extracted from only 17 tobacco dry seeds (1 mg DW), indicating that the efficiency of analysis of endogenous plant hormones strongly depends on the detection sensitivity of the method. Our analytical approach will be useful for in-depth studies on complex plant hormonal metabolism.

  16. Development of a method for comprehensive and quantitative analysis of plant hormones by highly sensitive nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Izumi, Yoshihiro; Okazawa, Atsushi; Bamba, Takeshi; Kobayashi, Akio [Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan); Fukusaki, Eiichiro, E-mail: fukusaki@bio.eng.osaka-u.ac.jp [Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan)

    2009-08-26

    In recent plant hormone research, there is an increased demand for a highly sensitive and comprehensive analytical approach to elucidate the hormonal signaling networks, functions, and dynamics. We have demonstrated the high sensitivity of a comprehensive and quantitative analytical method developed with nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry (LC-ESI-IT-MS/MS) under multiple-reaction monitoring (MRM) in plant hormone profiling. Unlabeled and deuterium-labeled isotopomers of four classes of plant hormones and their derivatives, auxins, cytokinins (CK), abscisic acid (ABA), and gibberellins (GA), were analyzed by this method. The optimized nanoflow-LC-ESI-IT-MS/MS method showed ca. 5-10-fold greater sensitivity than capillary-LC-ESI-IT-MS/MS, and the detection limits (S/N = 3) of several plant hormones were in the sub-fmol range. The results showed excellent linearity (R{sup 2} values of 0.9937-1.0000) and reproducibility of elution times (relative standard deviations, RSDs, <1.1%) and peak areas (RSDs, <10.7%) for all target compounds. Further, sample purification using Oasis HLB and Oasis MCX cartridges significantly decreased the ion-suppressing effects of biological matrix as compared to the purification using only Oasis HLB cartridge. The optimized nanoflow-LC-ESI-IT-MS/MS method was successfully used to analyze endogenous plant hormones in Arabidopsis and tobacco samples. The samples used in this analysis were extracted from only 17 tobacco dry seeds (1 mg DW), indicating that the efficiency of analysis of endogenous plant hormones strongly depends on the detection sensitivity of the method. Our analytical approach will be useful for in-depth studies on complex plant hormonal metabolism.

  17. Determination of the brominated flame retardant, hexabroomcyclodocane in sediments and biota by liquid chromatography-electrospray ionization mass spectrometry

    NARCIS (Netherlands)

    Morris, S.; Bersuder, P.; Allchin, C.R.; Zegers, B.; Boon, J.P.; Leonards, P.E.G.; Boer, de J.

    2006-01-01

    A method involving reversed-phase, liquid chromatography coupled to electrospray ionisation mass spectrometry (LC-ESI-MS) was developed for separation, detection and quantitation of the alpha-, beta- and gamma-diastereoisomers of hexabromocyclododecane (HBCD). To address the lack of environmental da

  18. Characterisation of tryptic peptides of phosphorylated tyrosine hydroxylase by high-pressure liquid chromatography electrospray ionisation mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Graham, Mark E. [Molecular Structure and Detection Group, School of Environmental and Life Sciences, University of Newcastle, Callaghan, NSW 2308 (Australia); Dickson, Phillip W. [School of Biomedical Science, University of Newcastle, Callaghan, NSW 2308 (Australia); Dunkley, Peter R. [School of Biomedical Science, University of Newcastle, Callaghan, NSW 2308 (Australia); Nagy-Felsobuki, Ellak I. von [Molecular Structure and Detection Group, School of Environmental and Life Sciences, University of Newcastle, Callaghan, NSW 2308 (Australia)]. E-mail: ellak@newcastle.edu.au

    2005-03-01

    Tyrosine hydroxylase (TH) is involved in the biosynthesis of catecholamines and is activated by phosphorylation. Phosphorylated TH was analysed using high-pressure liquid chromatography combined with electrospray mass spectrometry (HPLC ESI-MS). Two mass scanning methods were used to detect tryptic cleavage products of TH. In the positive electrospray ionisation mode (ESI+), the peptides that contain the phosphorylation sites of TH were identified. In the alternative method, a phosphopeptide was detected in the negative electrospray ionisation mode (ESI-) using single ion monitoring in combination with a sequential ESI+ switching experiment. A raised baseline interfered with detection of hydrophilic peptides in ESI-, with the signal-to-noise ratio indicating that the method was operating near the limit of detection for a conventional electrospray source. The switching method improved the certainty of identification of phosphopeptides.

  19. Characterisation of tryptic peptides of phosphorylated tyrosine hydroxylase by high-pressure liquid chromatography electrospray ionisation mass spectrometry

    International Nuclear Information System (INIS)

    Tyrosine hydroxylase (TH) is involved in the biosynthesis of catecholamines and is activated by phosphorylation. Phosphorylated TH was analysed using high-pressure liquid chromatography combined with electrospray mass spectrometry (HPLC ESI-MS). Two mass scanning methods were used to detect tryptic cleavage products of TH. In the positive electrospray ionisation mode (ESI+), the peptides that contain the phosphorylation sites of TH were identified. In the alternative method, a phosphopeptide was detected in the negative electrospray ionisation mode (ESI-) using single ion monitoring in combination with a sequential ESI+ switching experiment. A raised baseline interfered with detection of hydrophilic peptides in ESI-, with the signal-to-noise ratio indicating that the method was operating near the limit of detection for a conventional electrospray source. The switching method improved the certainty of identification of phosphopeptides

  20. Quantitative Analysis of Seven Triazine Herbicides by On-Line Micellar Electrokinetic Chromatography-Electrospray Ionization Mass Spectrometry

    International Nuclear Information System (INIS)

    This paper presents a successful demonstration of the on-line coupling of MEKC (micellar electrokinetic chromatography) to ESIMS (electrospray ionization mass spectrometry) for the quantitative analysis of seven s-triazine herbicides. The on-line MEKC-ESIMS was used to determine the structure of CE-separated peaks of seven triazine herbicides. The mixture of triazine herbicides was separated in a 20 mM sodium borate buffer (pH 8.5) containing 15 mM sodium dodecylsulfate (SDS) by using a bare fused-silica capillary. Electrospray ionization mass spectrometer was operated in the positive-ion mode when the mass spectra of seven triazine herbicides were observed from each peak, and the solution of water-methanol-formic acid (50/49/1 v/v/v) was used as a sheath liquid. The effects of SDS concentration, the run buffer pH, and the electric field on the separation of seven s-triazine herbicides were investigated. The MEKC-ESIMS detection showed 5 to 10 times higher sensitivity compared to the MEKC-UV detection. In addition, it did not need any pretreatment step

  1. Determination of diallyldimethylammonium chloride in drinking water by reversed-phase ion-pair chromatography-electrospray ionization mass spectrometry.

    Science.gov (United States)

    Jin, Fen; Hu, Jianying; Yang, Min; Jin, Xiaohui; He, Wenjie; Han, Hongda

    2006-01-01

    A method for the direct determination of diallyldimethylammonium chloride (DADMAC) in water samples, using ion-pair liquid chromatography-mass spectrometry system was developed. The chromatographic separation was performed using a C18 column. The type, the concentration of ion-pair reagent and the pH were optimized to give good chromatographic retention and sensitivity for DADMAC. Quantification was achieved in the positive electrospray ionization mode using selected ion monitoring. The cone voltage was also studied to establish the optimal experimental conditions. Finally, the reproducibility of the proposed method was shown by good run-to-run and day-to-day precision values. No sample preparation was required and the detection limit was 0.1 microg/L. The method was used to detect residual DADMAC at drinking water treatment plants in Tianjin, north China. The concentration of DADMAC observed in drinking water ranged from below quantitation limit to 22.0 microg/L. PMID:16243342

  2. Improvement of sugar analysis sensitivity using anion-exchange chromatography-electrospray ionization mass spectrometry with sheath liquid interface.

    Science.gov (United States)

    Xu, Xian-Bing; Liu, Ding-Bo; Guo, Xiao Ming; Yu, Shu-Juan; Yu, Pei

    2014-10-31

    A novel interface that enables high-performance anion-exchange chromatography (HPAEC) to be coupled with electrospray ionization (ESI) mass spectrometry (MS) is reported. A sheath liquid consisting of 50mM NH4Ac in isopropanol with 0.05% acetic acid, infused at a flow rate of 3μL/min at the tip of the electrospray probe, requires less ESI source cleaning and promotes efficient ionization of mono- and di-carbohydrates. The results suggest that use of a sheath liquid interface rather than a T-joint allows volatile ammonium salts to replace non-volatile metal salts as modifiers for improving sugar ESI signals. The efficient ionization of mono- and di-carbohydrates in the ESI source is affected by the sheath liquid properties such as buffer concentration and type of organic solvent. HPAEC-ESI-MS was used for the analysis of monocarbohydrates in pectins, particularly co-eluted sugars, and the performance was evaluated. Addition of a make-up solution through the sheath liquid interface proved to be an efficient tool for enhancing the intensities of sugars analyzed using HPAEC-ESI-MS. PMID:25246101

  3. Detection of 20 carbamate pesticides in asparagus by ultra performance liquid chromatography-electrospray ionization-mass spectrometry-mass spectrometry%超高效液相色谱-电喷雾串联四极杆质谱法检测芦笋中20种氨基甲酸酯类农药残留

    Institute of Scientific and Technical Information of China (English)

    赵晓琳; 霍乃蕊; 花锦; 宋欢

    2015-01-01

    目的:建立芦笋及其罐头制品中20种氨基甲酸酯类农药残留的定性定量分析方法。方法采用改进的 QuEchERS 法提取和净化,利用超高效液相色谱-电喷雾串联四极杆质谱仪,在多反应监测正离子扫描模式下对样品进行添加回收率试验。结果分别对绿芦笋、白芦笋、绿芦笋罐头、白芦笋罐头4种空白基质添加0.005~0.050 mg/kg农药样品进行回收率试验,回收率为62.44%~85.99%,定量限均为0.005 mg/kg, RSD均小于9%。结论该方法简单快速,灵敏度高,能够同时满足芦笋及其罐头制品中20种氨基甲酸酯类农药残留的检测要求。%Objective To establish an ultra performance liquid chromatography-electrospray ionization-mass spectrometry-mass spectrometry method for detecting of 20 kinds of carbamate pesticides in asparagus and asparagus products. Methods Samples were extracted by modified QuEchERS method, and the mode of multi-reaction monitoring positive ion scanning was applied for analysis by ultra high performance liquid chromatography-electrospray tandem quadrupole mass spectrometer. Results The blank matrixes (green asparagus, white asparagus, canned white asparagus, canned white asparagus) were added 0.005~0.050 mg/kg carbamate pesticides separately and recovery tests were performed. Results demonstrated that the recovery rates were in the range of 62.44%~85.99% and the limits of quantification were 0.005 mg/kg for all the 20 carbamate pesticides tested with the relative standard deviations (RSDs) below 9%. Conclusion The method, not only simple and fast but also high sensitive, can satisfy the international detection requirement for 20 carbamate pesticides residue in asparagus product simultaneously.

  4. Characterization of heat-labile toxin-subunit B from Escherichia coli by liquid chromatography-electrospray ionization-mass spectrometry and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

    Science.gov (United States)

    Sospedra, I; De Simone, C; Soriano, J M; Mañes, J; Ferranti, P; Ritieni, A

    2012-11-01

    The possibilities of characterizing the heat-labile enterotoxin (LT) of enterotoxigenic Escherichia coli (ETEC) by liquid chromatography electrospray mass spectrometry (LC/ESI-MS) and matrix-assisted laser desorption with time-of-flight mass spectrometry (MALDI-TOF-MS) were investigated. The B subunit from recombinant E. coli (expression in Pichia pastoris) can be detected by LC/ESI-MS expressed in P. pastoris and the charge envelope signals can be observed; LC/ESI-MS and MALDI-TOF-MS analysis allowed the acquisition of labile toxin subunit B (LTB) molecular weight and preliminary structural characterization of LTB toxin. MALDI-TOF analysis after reduction and alkylation of the protein evidenced the presence of one disulfide bond in the structure of the protein. Confirmatory analysis was carried out by detection of most of the tryptic fragments of the B subunit by MALDI-TOF-MS, obtaining total coverage of the protein sequence. Possible biovariations in the toxin can mostly be determined by sequencing, where an increase of molecular mass in the N-terminal side of the protein was identified. This modification may be due to an O-GlcNAc-1-phosphorylation. PMID:22921353

  5. Determination of the metabolic profile of gentianine after oral administration to rats by high performance liquid chromatography/electrospray ionization-trap mass spectrometry.

    Science.gov (United States)

    Wu, Xiuhong; Tang, Shuhan; Jin, Yan; Wang, Shanshan; Wang, Xijun; Hattori, Masao; Zhang, Hailong; Wang, Zhigang

    2015-05-01

    We investigated the metabolic fate of gentianine after oral administration to Wistar rats for the first time. Liquid chromatography/ion trap mass spectrometry detected four metabolites secogentianoxide, gentiandiol, gentianepoxide and gentianoxide in rat plasma together with the original compound gentianine. The structures of the metabolites were identified by comparing the retention times, as well as MS (mass) and MS/MS (tandem mass) spectra with those of authentic compounds, which were synthesized from gentianine or isolated from the urine. Three of the metabolites, secogentianoxide, gentianepoxide and gentianoxide, are novel compounds. The major in vivo metabolic processes associated with gentianine include N-oxide, epoxidation, dihydroxylation of double bond and hydrolysis of lactone. Gentianine together with the metabolites in plasma were quantified using gentianone as the internal standard. The mean C(max) of G0, G1, G2 and G3 are 425.76, 287.56, 188.45 and 85.05 ng/mL, respectively. The mean T(max) of G0, G1, G2 and G3 are 1.16, 3.87, 6.23 and 4.28 h, respectively. The mean T(1/2) of G0, G1, G2 and G3 are 5.23, 12.34, 7.78 and 5.64 h, respectively. A comprehensive metabolic pathway was proposed. The new metabolites may shed light on clinical efficacy of gentianine. PMID:25813903

  6. A Nanoparticle-based Solid Phase Extraction Method for Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometric Analysis

    OpenAIRE

    Song, Yaru; Zhao, Shulin; Tchounwou, Paul; Liu, Yi-Ming

    2007-01-01

    A solid-phase extraction (SPE) procedure with the use of superparamagnetic Fe3O4 nanoparticles as extracting agent was developed for HPLC-ESI-MS/MS analysis. Four most heavily used triazine pesticides (herbicides) were taken as the test compounds. The NPs showed an excellent capability to retain the compounds tested, and a quantitative extraction was achieved within 10 min under the testing conditions, i.e. 100 μL NP solution was added to 400 mL sample in a beaker with stirring. After extract...

  7. Analysis of iridoid glucosides in Hedyotis diffusa by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Li, Cunman; Xue, Xingya; Zhou, Dayong; Zhang, Feifang; Xu, Qing; Ren, Lingling; Liang, Xinmiao

    2008-09-10

    An HPLC-DAD-ESI-MS/MS method was developed for analysis of iridoid glucosides (IGs) from Hedyotis diffusa Willd. The optimized separation condition was achieved with the Complex Sample Analysis Software System (CSASS) software, under which the whole analytes were achieved complete resolution especially for some isomeric IGs. Based on the UV and fragmentations, eleven IGs were detected. According to the fragmentation patterns of the three standard IGs, especially those of the isomeric standards, seven IGs including three pairs of isomers were unambiguous/tentatively identified. For the isomeric IGs with methyl ester or carboxyl group at C-4, the extents of the losses of CH3OH and/or H2O from their molecular and/or the aglycone adducts are useful for the differentiation of the stereoisomers in positive ion (PI) mode, which depends on the stereochemistry of the hydroxyl group on the cyclopentanoid unit. PMID:18579330

  8. Study of matrix effects for liquid chromatography-electrospray ionization tandem mass spectrometric analysis of 4 aminoglycosides residues in milk.

    Science.gov (United States)

    Wang, Yuan; Li, Shaohui; Zhang, Feifang; Lu, Yifeng; Yang, Bingcheng; Zhang, Feng; Liang, Xinmiao

    2016-03-11

    Matrix effect (ME) is always a major issue for the development of LC-MS/MS method. ME resulting from co-eluting residual matrix components can affect the ionization efficiency of target analytes, leading to quantification errors of the analytes of interest. The present work evaluates MEs of milk samples on simultaneous analysis of four aminoglycosides residues via LC-ESI/MS/MS including streptomycin, dihydrostreptomycin, spectinomycin and kanamycin. Approaches to reduce MEs were examined: optimization of the sample preparation, sample dilution and lower flow rate used. Three commercial sorbents were tested including Oasis MCX, Oasis HLB and Oasis WCX. WCX behaved better for all analytes, but high MEs (80.8-134.9%) were obtained. Therefore, a consecutive SPE of tC18-WCX was found to effectively reduce ME. Milk samples from different manufacturers were analyzed and low MEs (85.6-112.9%) were obtained. PMID:26875117

  9. Multi residue screening of intact testosterone esters and boldenone undecylenate in bovine hair using liquid chromatography electrospray tandem mass spectrometry

    NARCIS (Netherlands)

    Nielen, M.W.F.; Lasaroms, J.J.P.; Mulder, P.P.J.; Hende, van J.; Rhijn, van J.A.; Groot, M.J.

    2006-01-01

    The abuse of esters of natural androgenic steroids in cattle fattening and sports is hard to control via routine urine testing. The esters are rapidly hydrolysed in vivo into substances which are also endogenously present in urine. In veterinary control strange findings of 17ß-testosterone and 17¿-t

  10. Screening for gestagens in kidney fat using accelerated solvent extraction and liquid chromatography electrospray tandem mass spectrometry

    NARCIS (Netherlands)

    Hooijerink, H.; Bennekom, van E.O.; Nielen, M.W.F.

    2003-01-01

    A screening method has been developed for the determination of various anabolic steroids in kidney fat. Fat samples are extracted and steroids are trapped "on-line" during accelerated solvent extraction (ASE). Following this initial extraction samples are further purified with C18 solid-phase extrac

  11. Determination of energy metabolites in cancer cells by porous graphitic carbon liquid chromatography electrospray ionization mass spectrometry for the assessment of energy metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Szoboszlai, Norbert, E-mail: szobosz@chem.elte.hu [Laboratory of Environmental Chemistry and Bioanalytics, Department of Analytical Chemistry, Institute of Chemistry, Eötvös Loránd University, Pázmány Péter stny 1/A, H-1117 Budapest (Hungary); Guo, Xinghua [Institute of Analytical Chemistry and Food Chemistry, Graz University of Technology, Stremayrgasse 9, 8010 Graz (Austria); Ozohanics, Olivér [Research Centre for Natural Sciences of the Hungarian Academy of Sciences, Pusztaszeri u. 59-67, H-1025 Budapest (Hungary); Oláh, Júlia [1st Institute of Pathology and Experimental Cancer Research, Semmelweis University, H-1085 Budapest (Hungary); Gömöry, Ágnes [Research Centre for Natural Sciences of the Hungarian Academy of Sciences, Pusztaszeri u. 59-67, H-1025 Budapest (Hungary); Mihucz, Victor G. [Laboratory of Environmental Chemistry and Bioanalytics, Department of Analytical Chemistry, Institute of Chemistry, Eötvös Loránd University, Pázmány Péter stny 1/A, H-1117 Budapest (Hungary); Jeney, András [1st Institute of Pathology and Experimental Cancer Research, Semmelweis University, H-1085 Budapest (Hungary); Vékey, Károly [Research Centre for Natural Sciences of the Hungarian Academy of Sciences, Pusztaszeri u. 59-67, H-1025 Budapest (Hungary)

    2014-03-01

    Graphical abstract: - Highlights: • All types of sugar metabolites can be investigated in one run on graphitic stationary phase. • Method development for acidic metabolites of energy metabolism using a single LC–MS run. • Study of 15 acidic energy metabolites on a PGC column using common eluents. • Lactate, acidic amino acid, organic acid and sugar phosphate determination in a single run. • Metabolism of U-{sup 13}C glucose and 1-{sup 13}C acetate in ZR-75-1 cells studied. - Abstract: A high performance liquid chromatography (HPLC) tandem mass spectrometric (MS/MS) method has been developed for the simultaneous determination of fifteen glucose, or acetate derived metabolites isolated from tumor cells. Glycolytic and tricarboxylic acid (TCA) cycle metabolites as well as acidic amino acids were separated on a HPLC porous graphitic carbon (PGC) column and simultaneously determined by means of triple quadrupole MS/MS using multiple reaction monitoring (MRM). Target compounds were eluted within 10 min with 8% v/v formic acid as an electronic modifier added to a 4:1 v/v methanol water mobile phase. The calibration is linear in the 1–100 μM concentration range for each analyte. The limit of detection ranges between 0.39 and 2.78 μM for the analytes concerned. To test the PGC–HPLC–MS/MS method in metabolomic studies, ZR-75.1 human mammary adenocarcinoma cells were labeled with U-{sup 13}C glucose or 1-{sup 13}C acetate. Applying the MRM mode, the incorporation of {sup 13}C into metabolites, isolated from the tumor cells, and derived from glucose or acetate, could be properly identified.

  12. Determination of energy metabolites in cancer cells by porous graphitic carbon liquid chromatography electrospray ionization mass spectrometry for the assessment of energy metabolism

    International Nuclear Information System (INIS)

    Graphical abstract: - Highlights: • All types of sugar metabolites can be investigated in one run on graphitic stationary phase. • Method development for acidic metabolites of energy metabolism using a single LC–MS run. • Study of 15 acidic energy metabolites on a PGC column using common eluents. • Lactate, acidic amino acid, organic acid and sugar phosphate determination in a single run. • Metabolism of U-13C glucose and 1-13C acetate in ZR-75-1 cells studied. - Abstract: A high performance liquid chromatography (HPLC) tandem mass spectrometric (MS/MS) method has been developed for the simultaneous determination of fifteen glucose, or acetate derived metabolites isolated from tumor cells. Glycolytic and tricarboxylic acid (TCA) cycle metabolites as well as acidic amino acids were separated on a HPLC porous graphitic carbon (PGC) column and simultaneously determined by means of triple quadrupole MS/MS using multiple reaction monitoring (MRM). Target compounds were eluted within 10 min with 8% v/v formic acid as an electronic modifier added to a 4:1 v/v methanol water mobile phase. The calibration is linear in the 1–100 μM concentration range for each analyte. The limit of detection ranges between 0.39 and 2.78 μM for the analytes concerned. To test the PGC–HPLC–MS/MS method in metabolomic studies, ZR-75.1 human mammary adenocarcinoma cells were labeled with U-13C glucose or 1-13C acetate. Applying the MRM mode, the incorporation of 13C into metabolites, isolated from the tumor cells, and derived from glucose or acetate, could be properly identified

  13. Comparison of microbial communities in Lake Tahoe surface sample with Tonga Trench water column samples using High Pressure Liquid Chromatography - Electrospray Ionization - Mass Spectroscopy (HPLC - ESI - MS) and Global Natural Products Social Molecular Network (GNPS)

    Science.gov (United States)

    Belmonte, M. A.

    2015-12-01

    Intact polar lipids (IPLs) are lipids composed of a head group, a glycerol, and a fatty acid chain that make up the lipid bilayer of cell membranes in living cells; and the varying head groups can be indicative of the type of microbes present in the environment (Van Mooy 2010). So by distinguishing and identifying the IPL distribution in an environment one can make inferences about the microbial communities in the said environment. In this study, we used High Pressure Liquid Chromatography-Electrospray Ionization- Mass Spectroscopy (HPLC-ESI-MS) and Global Natural Products Social Molecular Networking (GNPS) to compare the IPL distributions of two oligotrophic environments: surface waters of Lake Tahoe in the Sierra Nevada Mountains, and the water column of the Tonga Trench in the South Pacific. We hypothesized that the similar nutrient dynamics of the two oligotrophic environments would result in similar eukaryotic and prokaryotic communities, which would be reflected in the IPL composition of suspended particulate organic matter (POM). For simplicity we focused on the classes of IPLs most commonly observed in the marine environment: phosphotidylglycerol (PG), phosphotidylethanolamine (PE), diacylglyceryl-trimethyl-homoserine (DGTS), diacylglyceryl-hydroxymethyl-trimethylalanine (DGTA), sulfoquinovosyldiacylglycerol (SQDG), monoglycosyldiacylglycerol (MGDG) and diglycosyldiacylglycerol (DGDG). Our results showed that all of the marine IPLs of interest were present in Lake Tahoe which confirms that there are many of the same microbial communities in the fresh waters of Lake Tahoe and the salt waters Tonga Trench.

  14. Characterization of isoquinoline alkaloids, diterpenoids and steroids in the Chinese herb Jin-Guo-Lan (Tinospora sagittata and Tinospora capillipes) by high-performance liquid chromatography/electrospray ionization with multistage mass spectrometry.

    Science.gov (United States)

    Zhang, Yufeng; Shi, Qirong; Shi, Peiying; Zhang, Weidong; Cheng, Yiyu

    2006-01-01

    This study sought to determine the primary components (isoquinoline alkaloids, diterpenoids and steroids) in crude extracts of the Chinese herb Jin-Guo-Lan, prepared from the roots of Tinospora sagittata and T. capillipes, by liquid chromatography/electrospray ionization multistage mass spectrometry coupled with diode-array detection (LC-DAD/ESI-MS(n)). After separation on a reversed-phase C(18) column using gradient elution, positive and negative ESI-MS experiments were performed. In positive ion mode, the three types of compounds showed very different characteristic ions: strong [M](+) or [M+H](+) ions were observed for isoquinoline alkaloids; [M+NH(4)](+) and/or [M+H-CO(2)](+) for diterpenoids; [M+H-nH(2)O](+) (n=1-3) for steroids. These adduct ions and/or fragments were used to deduce the mass and categories of known and unknown components in crude extracts, and their structures were further confirmed by ESI-MS(n) in positive ion mode. Moreover, UV absorption peaks obtained from DAD provided useful functional group information to aid the MS(n)-based identification. As a result, 11 compounds were unambiguously identified by comparing with standard compounds and 13 compounds were tentatively identified or deduced according to their MS(n) data. Two of these compounds (13-hydroxycolumbamine and 13-hydroxyjatrorrhizine) were found to be new compounds and another one (13-hydroxypalmatine) was detected for the first time as a natural product. In addition, a [M-*CH(3)-H(2)O](*+) ion in MS(2) of [M](+) after in-source collision-induced dissociation was used to differentiate positional isomers of protoberberine alkaloids, columbamine and jatrorrhizine. Although the roots of T. sagittata and T. capillipes contain almost identical compounds, the content of the compounds in them is dramatically different, suggesting the necessity for further comparison of the bioactivities of the two species. PMID:16817243

  15. Identification of Intact High Molecular Weight Glutenin Subunits from the Wheat Proteome Using Combined Liquid Chromatography-Electrospray Ionization Mass Spectrometry

    OpenAIRE

    Lagrain, Bert; Brunnbauer, Markus; Rombouts, Ine; Koehler, Peter

    2013-01-01

    The present paper describes a method for the identification of intact high molecular weight glutenin subunits (HMW-GS), the quality determining proteins from the wheat storage proteome. The method includes isolation of HMW-GS from wheat flour, further separation of HMW-GS by reversed-phase high-performance liquid chromatography (RP-HPLC), and their subsequent molecular identification with electrospray ionization mass spectrometry using a quadrupole-time-of-flight mass analyzer. For HMW-GS iso...

  16. Regiospecific analysis of neutral ether lipids by liquid chromatography/electrospray ionization/single quadrupole mass spectrometry: validation with synthetic compounds

    DEFF Research Database (Denmark)

    Hartvigsen, Karsten; Ravandi, A.; Bukhave, Klaus;

    2001-01-01

    A reversed-phase high-performance liquid chromatography (HPLC) method with on-line electrospray ionization/collision-induced dissociation/mass spectrometry (ESI/CID/MS) is presented for the regiospecific analysis of synthetic reference compounds of neutral ether lipids. The reference compounds were...... are suggested for each neutral ether lipid class. The present study demonstrates that reversed-phase HPLC and positive ion ESI/CID/MS provide direct and unambiguous information about the configuration and identity of molecular species in neutral 1-O-alkyl-sn-glycerol classes....... characterized by chromatographic retention times, full mass spectra, and fragmentation patterns as an aid to clarify the regiospecificity of ether lipids from natural sources. The results clearly show that single quadrupole mass spectroscopic analysis may elucidate the regiospecific structure of neutral ether...

  17. Classification of cultivation locations of panax quinquefolius L samples using high performance liquid chromatography-electrospray ionization mass spectrometry and chemometric analysis

    Science.gov (United States)

    Panax quinquefolius L (P. quinquefolius L) samples grown in the United States and China were analyzed with high performance liquid chromatography-mass spectrometry (HPLC—MS). Prior to classification, the two-way datasets were subjected to pretreatment including baseline correction and retention ti...

  18. Identification of intact high molecular weight glutenin subunits from the wheat proteome using combined liquid chromatography-electrospray ionization mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Bert Lagrain

    Full Text Available The present paper describes a method for the identification of intact high molecular weight glutenin subunits (HMW-GS, the quality determining proteins from the wheat storage proteome. The method includes isolation of HMW-GS from wheat flour, further separation of HMW-GS by reversed-phase high-performance liquid chromatography (RP-HPLC, and their subsequent molecular identification with electrospray ionization mass spectrometry using a quadrupole-time-of-flight mass analyzer. For HMW-GS isolation, wheat proteins were reduced and extracted from flour with 50% 1-propanol containing 1% dithiothreitol. HMW-GS were then selectively precipitated from the protein mixture by adjusting the 1-propanol concentration to 60%. The composition of the precipitated proteins was first evaluated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis with Coomassie staining and RP-HPLC with ultraviolet detection. Besides HMW-GS (≥65%, the isolated proteins mainly contained ω5-gliadins. Secondly, the isolated protein fraction was analyzed by liquid chromatography-mass spectrometry. Optimal chromatographic separation of HMW-GS from the other proteins in the isolated fraction was obtained when the mobile phase contained 0.1% trifluoroacetic acid as ion-pairing agent. Individual HMW-GS were then identified by determining their molecular masses from the high-resolution mass spectra and comparing these with theoretical masses calculated from amino acid sequences. Using formic acid instead of trifluoroacetic acid in the mobile phase increased protein peak intensities in the base peak mass chromatogram. This allowed the detection of even traces of other wheat proteins than HMW-GS in the isolated fraction, but the chromatographic separation was inferior with a major overlap between the elution ranges of HMW-GS and ω-gliadins. Overall, the described method allows a rapid assessment of wheat quality through the direct determination of the HMW-GS composition and

  19. Liquid chromatography-electrospray ionization mass spectrometry of the diarrhetic shellfish-poisoning toxins okadaic acid, dinophysistoxin-1 and pectenotoxin-6 in bivalves.

    Science.gov (United States)

    Suzuki, T; Yasumoto, T

    2000-04-01

    Determination of diarrhetic shellfish-poisoning (DSP) toxins, okadaic acid (OA), dinophysistoxin-1 (DTX1) and pectenotoxin-6 (PTX6) was carried out by liquid chromatography (LC) followed by on-line atmospheric pressure electrospray ionization-mass spectrometric (ESI-MS) detection with a heated capillary interface. Mass spectra of authentic OA, DTXI and PTX6 standards exhibited abundant [M-H] at m/z 803, 817 and 887, respectively. Linearity of peak area obtained by selected-ion monitoring (SIM) for [M-H]- of each toxin was confirmed over a wide range of concentrations from 10 pg to 30 ng. LC-ESI-MS analysis of OA, DTX1 and PTX6 in scallops and mussels, collected at the same site (Mutsu Bay, Japan), was carried out. Scallops and mussels collected at the same site showed different toxin profiles. Although PTX6 was detected from scallops, it was not detected from mussels. PMID:10817358

  20. Selenium metabolomics in yeast using complementary reversed-phase/hydrophilic ion interaction (HILIC) liquid chromatography-electrospray hybrid quadrupole trap/Orbitrap mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Arnaudguilhem, C.; Bierla, K.; Ouerdane, L.; Preud' homme, H. [CNRS/UPPA, Laboratoire de Chimie Analytique Bio-inorganique et Environnement, UMR 5254, Helioparc, 2, Av. Pr. Angot, 64053 Pau (France); Yiannikouris, A. [Alltech Inc., 3031 Catnip Hill Pike, Nicholasville, KY (United States); Lobinski, R., E-mail: ryszard.lobinski@univ-pau.fr [CNRS/UPPA, Laboratoire de Chimie Analytique Bio-inorganique et Environnement, UMR 5254, Helioparc, 2, Av. Pr. Angot, 64053 Pau (France); Chair of Analytical Chemistry, Warsaw University of Technology, 00-664 Warszawa (Poland)

    2012-12-13

    Highlights: Black-Right-Pointing-Pointer The use of bimodal chromatographic separation enlarged amount of compounds identified. Black-Right-Pointing-Pointer The method allowed the largest scale ever (>60 compounds) speciation analysis of selenium metabolites in Se-rich yeast. Black-Right-Pointing-Pointer The estimated concentration of compounds was given. - Abstract: A high efficiency chromatographic separation on a porous graphitic carbon stationary phase was developed for a large-scale separation of selenium metabolites in Se-rich yeast prior to their identification by electrospray hybrid quadrupole trap/Orbitrap mass spectrometry (Orbitrap MS{sup n}). The reversed-phase (RP) separation mode offered distinctly higher separation efficiency than the hydrophilic ion interaction (HILIC) mode. The latter was nevertheless complementary and useful to validate the detection of several compounds. The method allowed the detection of 64 metabolites including 30 Se-Se or Se-S conjugates (3 triple S/Se/S ones) and 14 selenoethers. 21 previously unreported metabolites were detected on the basis of the selenium isotopic pattern usually matched with the sub-ppm mass accuracy. 9 of these metabolites were subsequently identified using the multi-stage high mass accuracy (<5 ppm) mass spectrometry. The identified metabolites (and their groups) were quantified on-line by ICP-MS fitted with a frequency-matching generator allowing a quasi-uniform response over the large (20-90%) acetonitrile mobile phase concentration range. The morphology of HPLC-ICP-MS chromatograms was remarkably similar to that of HPLC multi-ion extracted ESI-MS chromatograms. The detection limits obtained by ICP MS and ESI MS were 1 and 2 ppb, respectively.

  1. Efficient mining of myxobacterial metabolite profiles enabled by liquid chromatography-electrospray ionisation-time-of-flight mass spectrometry and compound-based principal component analysis

    International Nuclear Information System (INIS)

    Bacteria producing secondary metabolites are an important source of natural products with highly diverse structures and biological activities. Developing methods to efficiently mine procaryotic secondary metabolomes for the presence of potentially novel natural products is therefore of considerable interest. Modern mass spectrometry-coupled liquid chromatography can effectively capture microbial metabolic diversity with ever improving sensitivity and accuracy. In addition, computational and statistical tools increasingly enable the targeted analysis and exploration of information-rich LC-MS datasets. In this article, we describe the use of such techniques for the characterization of myxobacterial secondary metabolomes. Using accurate mass data from high-resolution ESI-TOF measurements, target screening has facilitated the rapid identification of known myxobacterial metabolites in extracts from nine Myxococcus species. Furthermore, principal component analysis (PCA), implementing an advanced compound-based bucketing approach, readily revealed the presence of further compounds which contribute to variation among the metabolite profiles under investigation. The generation of molecular formulae for putative novel compounds with high confidence due to evaluation of both exact mass position and isotopic pattern, is exemplified as an important key for de-replication and prioritization of candidates for further characterization

  2. Regiospecific analysis of neutral ether lipids by liquid chromatography/electrospray ionization/single quadrupole mass spectrometry: validation with synthetic compounds

    DEFF Research Database (Denmark)

    Hartvigsen, Karsten; Ravandi, A.; Bukhave, Klaus; Hølmer, Gunhild Kofoed; Kuksis, A.

    2001-01-01

    + H - H2O](+), whereas the reverse situation characterized the sn-3 species. Furthermore, corresponding sn-2 and sn-3 species were separated by the chromatographic system. However, loss of water was promoted as fatty acid unsaturation was raised, which may complicate interpretation of the mass spectra...... are suggested for each neutral ether lipid class. The present study demonstrates that reversed-phase HPLC and positive ion ESI/CID/MS provide direct and unambiguous information about the configuration and identity of molecular species in neutral 1-O-alkyl-sn-glycerol classes....

  3. Ion chromatography electrospray ionization mass spectrometry method development and investigation of lithium hexafluorophosphate-based organic electrolytes and their thermal decomposition products.

    Science.gov (United States)

    Kraft, Vadim; Grützke, Martin; Weber, Waldemar; Winter, Martin; Nowak, Sascha

    2014-08-01

    A method based on the coupling of ion chromatography (IC) and electrospray ionization mass spectrometry (ESI-MS) for the separation and determination of thermal decomposition products of LiPF6-based organic electrolytes is presented. The utilized electrolytes, LP30 and LP50, are commercially available and consist of 1mol/l LiPF6 dissolved in ethylene carbonate/dimethyl carbonate and ethylene carbonate/ethyl methyl carbonate, respectively. For the separation method development three ion chromatographic columns with different capacity and stationary phase were used and compared. Besides the known hydrolysis products of lithium hexafluorophosphate, several new organophosphates were separated and identified with the developed IC-ESI-MS method during aging investigations of the electrolytes. The chemical structures were elucidated with IC-ESI-MS/MS. PMID:24939088

  4. Antioxidant activity and identification of bioactive compounds from leaves of Anthocephalus cadamba by ultra-performance liquid chromatography/electrospray ionization quadrupole time of flight mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Madhu Chandel; Upendra Sharma; Neeraj Kumar; Bikram Singh; Satwinderjeet Kaur

    2012-01-01

    Objective: To evaluate the antioxidant potential of different extract/fractions of Anthocephalus cadamba (A. cadamba) (Roxb.) Miq. (Rubiaceae) and study the tentative identification of their active constituents. Methods: The extract/fractions were screened for antioxidant activity using various in vitro assays viz. DPPH assay, ABTS assay, superoxide anion radical scavenging assay, reducing power assay and plasmid DNA nicking assay. Total phenolic content of extract/fractions was determined by colorimetric method. An ultra-performance LC-electrospray-quadrupole-time of flight mass spectrometry method was used to analyse the active constituents of extract/fractions of A. cadamba. Results: The ethyl acetate fraction was found to be most active fraction in all the assays as compared to other extract/fractions. The IC50 value of ethyl acetate fraction (ETAC fraction) was 21.24 μg/mL, 1.12 μg/mL, 9.68 μg/mL and 57.81 μg/mL in DPPH assay, ABTS assay, reducing power assay and superoxide scavenging assay respectively. All the extract/fractions also showed the potential to protect the plasmid DNA (pBR322) against the attack of hydroxyl radicals generated by Fenton’s reagent. The bioactive compounds were identified by UPLC-ESI-QTOF-MS, by comparing the mass and λmax with literature values. Conclusions: The potential of the extract/fractions to scavenge different free radicals in different systems indicated that they may be useful therapeutic agents for treating radical-related pathologic damage.

  5. Column-switching high-performance liquid chromatography-electrospray ionization mass spectrometry for identification of heroin metabolites in human urine.

    Science.gov (United States)

    Katagi, M; Nishikawa, M; Tatsuno, M; Miki, A; Tsuchihashi, H

    2001-02-10

    In order to prove heroin (DAM) use, a simple, rapid and sensitive analytical method has been established by combining semi-microcolumn HPLC, a column switching technique and electrospray ionization mass spectrometry (ESI-MS). Urine samples were directly introduced to the system, and endogenous urinary constituents were removed by using on-line column switching solid-phase extraction with a strong cation-exchange (SCX) cartridge column (2.0 mm I.D. x 10 mm). Heroin and its metabolites enriched on the top of the column were then successfully analyzed with excellent separation by use of a SCX semi-microcolumn (1.5 mm I.D. x 150 mm), accompanied by ESI mass spectral detection. The proposed conditions are as follows: mobile phase, 10 mM ammonium acetate (pH 6.0)-acetonitrile (30:70, v/v) (for main separation) and 30 mM ammonium acetate (for trapping); flow-rates, 120 microl/min (for main separation) and 200 microl/min (for trapping); capillary voltage, +4.5 kV; cone voltage, 50 V. Linear calibration curves were obtained in the selected ion monitoring (SIM) mode using protonated molecular ions (m/z 370 for DAM, m/z 328 for MAM and m/z 286 for MOR) over the concentration ranges from 10 to 1000 ng/ml for morphine (MOR) and 1-100 ng/ml for DAM and 6-acetylmorphine (MAM). The detection limits were 0.1-3 ng/ml. Upon applying the scan mode, 2-30 ng/ml were the detection limits. The present HPLC-ESI-MS method was successfully applied to the determination of opiates in users' urine samples. PMID:11232848

  6. Metabolomics Analysis of Health Functions of Physalis Pubescens L. using by Ultra-performance Liquid Chromatography/Electrospray Ionization Quadruple Time-of-Flight Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    Hang Chu; Hui Sun; Guang-Li Yan; Ai-Hua Zhang; Chang Liu; Hui Dong; Xiang-Cai Meng; Xi-Jun Wang

    2015-01-01

    Herbal medicines may benefit from metabolomics studies, and applying metabolomics may provide answers about which herbal interventions may be effective for individuals, which metabolic processes are triggered, and the subsequent chemical pathways of activity. Physalis pubescens L (PPL) is an herbal fruit for one year living plant and has been developed into healthy function’s food. However, the mechanisms of health functions are still unclear. To comprehensively and holistically assess its anti-fatigue and antioxidant effects, a novel integrative metabolomics approach was applied. In this study, we present metabolomics analysis applying ultra performance liquid chromatography coupled to quadrupole with time-of-flight mass spectrometry (UPLC-Q/TOF-MS) to determine metabolite alterations after oral administration PPL to rats. Fifteen metabolites in urine were identified as potential biomarkers. Pattern analysis of the UPLC-Q/TOF-MS data disclosed that PPL could relieve fatigue rats by ameliorating the disturbance in amino acids metabolism and energy metabolism, alleviating the oxidative stress from reactive oxygen species and the inflammatory damage, and recovering the destructed regulation. Based on these results, we demonstrated that PPL is a promising source of natural anti-fatigue and antioxidants material for use in functional foods and medicines.

  7. Metabolomics Analysis of Health Functions of Physalis Pubescens L. using by Ultra-performance Liquid Chromatography/Electrospray Ionization Quadruple Time-of-Flight Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Hang Chu

    2015-07-01

    Full Text Available Herbal medicines may benefit from metabolomics studies, and applying metabolomics may provide answers about which herbal interventions may be effective for individuals, which metabolic processes are triggered, and the subsequent chemical pathways of activity. Physalis pubescens L (PPL is an herbal fruit for one year living plant and has been developed into healthy function's food. However, the mechanisms of health functions are still unclear. To comprehensively and holistically assess its anti-fatigue and antioxidant effects, a novel integrative metabolomics approach was applied. In this study, we present metabolomics analysis applying ultra performance liquid chromatography coupled to quadrupole with time-of-flight mass spectrometry (UPLC-Q/TOF-MS to determine metabolite alterations after oral administration PPL to rats. Fifteen metabolites in urine were identified as potential biomarkers. Pattern analysis of the UPLC-Q/TOF-MS data disclosed that PPL could relieve fatigue rats by ameliorating the disturbance in amino acids metabolism and energy metabolism, alleviating the oxidative stress from reactive oxygen species and the inflammatory damage, and recovering the destructed regulation. Based on these results, we demonstrated that PPL is a promising source of natural anti-fatigue and antioxidants material for use in functional foods and medicines.

  8. Use of a partial filling technique and reverse migrating micelles in the study of N-methylcarbamate pesticides by micellar electrokinetic chromatography-electrospray ionization mass spectrometry.

    Science.gov (United States)

    Molina, M; Wiedmer, S K; Jussila, M; Silva, M; Riekkola, M L

    2001-08-24

    This study describes three ways to couple micellar electrokinetic chromatography (MEKC) on-line with electrospray ionization mass spectrometry (ESI-MS) for the analysis of N-methylcarbamate pesticides. The methods involved the use of a partial filling (PF) technique under basic conditions and the use of reverse migrating micelles (RMMs) under acidic and basic conditions. The use of RMMs in basic electrolyte solutions required coated capillaries with low electroosmotic flows, and capillaries coated with anionic poly(sodium 2-acrylamide-2-methylpropanesulfonate) were selected for the purpose. Before the on-line MEKC-ESI-MS coupling, the MEKC and MS conditions were separately optimized under off-line conditions. The methods were compared in terms of detection limits and the stability of the electrospray process. The PF method offered good separation but poorer stability of the electrospray relative to the other methods. A more stable electrospray performance was obtained with use of RMMs in acidic electrolyte solutions, but some of the analytes were protonated and could not be detected due to the increase in their retention factors. However, with the use of anionic polymer-coated capillaries and RMMs at pH 8.5, all analytes were successfully separated. The high-salt stacking method was applied to improve the sensitivity of MEKC-ESI-MS and the detection limits were in the range of 0.04-2.0 microg/ml. PMID:11572389

  9. Analysis of phospholipid molecular species in brains from patients with infantile and juvenile neuronal-ceroid lipofuscinosis using liquid chromatography-electrospray ionization mass spectrometry.

    Science.gov (United States)

    Käkelä, Reijo; Somerharju, Pentti; Tyynelä, Jaana

    2003-03-01

    Phospholipids (PL) in cerebral cortex from patients with infantile (INCL or CLN1) and juvenile (JNCL or CLN3) forms of neuronal ceroid-lipofuscinosis (NCL) and controls were analysed by normal phase HPLC and on-line electrospray ionization ion-trap mass spectrometric detection (LC-ESI-MS). The method provided quantitative data on numerous molecular species of different PL classes, which are not achieved by using the conventional chromatographic methods. Compared with the controls, the INCL brains contained proportionally more phosphatidylcholine (PC), and less phosphatidylethanolamine (PE) and phosphatidylserine (PS). Different molecular species of PC, PE, PS, phosphatidylinositol and sphingomyelin were quantified using multiple internal PL standards that differed in fatty acyl chain length and thus allowed correction for chain length dependency of instrument response. In INCL cortex, which had lost 65% of the normal PL content, the proportions of polyunsaturated molecular species, especially the PS and PE that contained docosahexaenoic acid (22:6n-3), were dramatically decreased. The membranes may have adapted to this alteration by increasing the proportions of PL molecules substituted with monounsaturated and short-chain fatty acids. Lysobisphosphatidic acid was highly elevated in the INCL brain and consisted mostly of polyunsaturated species. It is possible that changes in the composition of PL membranes accelerate progression of INCL by altering signalling and membrane trafficking in neurons. PMID:12603829

  10. Determination of pharmaceutical compounds in surface- and ground-water samples by solid-phase extraction and high-performance liquid chromatography-electrospray ionization mass spectrometry

    Science.gov (United States)

    Cahill, J.D.; Furlong, E.T.; Burkhardt, M.R.; Kolpin, D.; Anderson, L.G.

    2004-01-01

    Commonly used prescription and over-the-counter pharmaceuticals are possibly present in surface- and ground-water samples at ambient concentrations less than 1 μg/L. In this report, the performance characteristics of a combined solid-phase extraction isolation and high-performance liquid chromatography–electrospray ionization mass spectrometry (HPLC–ESI-MS) analytical procedure for routine determination of the presence and concentration of human-health pharmaceuticals are described. This method was developed and used in a recent national reconnaissance of pharmaceuticals in USA surface waters. The selection of pharmaceuticals evaluated for this method was based on usage estimates, resulting in a method that contains compounds from diverse chemical classes, which presents challenges and compromises when applied as a single routine analysis. The method performed well for the majority of the 22 pharmaceuticals evaluated, with recoveries greater than 60% for 12 pharmaceuticals. The recoveries of angiotensin-converting enzyme inhibitors, a histamine (H2) receptor antagonist, and antihypoglycemic compound classes were less than 50%, but were retained in the method to provide information describing the potential presence of these compounds in environmental samples and to indicate evidence of possible matrix enhancing effects. Long-term recoveries, evaluated from reagent-water fortifications processed over 2 years, were similar to initial method performance. Method detection limits averaged 0.022 μg/L, sufficient for expected ambient concentrations. Compound-dependent matrix effects on HPLC/ESI-MS analysis, including enhancement and suppression of ionization, were observed as a 20–30% increase in measured concentrations for three compounds and greater than 50% increase for two compounds. Changing internal standard and more frequent ESI source maintenance minimized matrix effects. Application of the method in the national survey demonstrates that several

  11. Quantitative analysis of phenolic compounds in Chinese hawthorn (Crataegus spp.) fruits by high performance liquid chromatography-electrospray ionisation mass spectrometry.

    Science.gov (United States)

    Liu, Pengzhan; Kallio, Heikki; Lü, Deguo; Zhou, Chuansheng; Yang, Baoru

    2011-08-01

    Eleven major phenolic compounds (hyperoside, isoquercitrin, chlorogenic acid, ideain, epicatechin, two procyanidin (PA) dimers, three PA trimers and a PA dimer-hexoside) were quantified in the fruits of 22 cultivars/origins of three species of the Chinese hawthorn (Crataegus spp.) by HPLC-ESI-MS-SIR. Hyperoside (0.1-0.8mg/g dry mass [DM]), isoquercitrin (0.1-0.3mg/g DM), chlorogenic acid (0.2-1.6mg/g DM), epicatechin (0.9-11.7mg/g DM), PA B2 (0.7-12.4mg/g DM), PA dimer II (0.1-1.5mg/g DM), PA trimer I (0.1-2.7mg/g DM), PA trimer II (0.7-6.9mg/g DM), PA trimer III (0.01-1.2mg/g DM) and a PA dimer-hexoside (trace-1.1mg/g DM) were detected in all the samples. Ideain (0.0-0.7mg/g DM) was found in all the samples except Crataegus scabrifolia. Significant correlations between the contents of individual PA aglycons were observed (r>0.9, P<0.01). A strong correlation between flavonols was also shown (r=0.71, P<0.01). Fruits of Crataegus pinnatifida var. major had higher contents of PAs but lower contents of flavonols compared with Crataegus brettschneideri. The fruits of C. scabrifolia contained the highest level of PA dimer-hexoside, which was present in trace amounts in the fruits of C. pinnatifida. PMID:25214140

  12. Quantitative analysis of N-glycans from human alfa-acid-glycoprotein using stable isotope labeling and zwitterionic hydrophilic interaction capillary liquid chromatography electrospray mass spectrometry as tool for pancreatic disease diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Giménez, Estela, E-mail: estelagimenez@ub.edu [Department of Analytical Chemistry, University of Barcelona, Diagonal 647, E-08028 Barcelona (Spain); Balmaña, Meritxell [Biochemistry and Molecular Biology Unit, Department of Biology, University of Girona, Campus Montilivi s/n, 17071 Girona (Spain); Figueras, Joan [Department of Surgery, Dr. Josep Trueta University Hospital, IdlBGi, 17007 Girona (Spain); Fort, Esther [Digestive Unit, Dr. Josep Trueta University Hospital, 17007 Girona (Spain); Bolós, Carme de [Gastroesophagic Cancer Research Group, Research Programme in Cancer, Hospital del Mar Medical Research Institute (IMIM), Dr. Aiguader, 88, 08003 Barcelona (Spain); Sanz-Nebot, Victòria [Department of Analytical Chemistry, University of Barcelona, Diagonal 647, E-08028 Barcelona (Spain); Peracaula, Rosa [Biochemistry and Molecular Biology Unit, Department of Biology, University of Girona, Campus Montilivi s/n, 17071 Girona (Spain); Rizzi, Andreas [Institute of Analytical Chemistry, University of Vienna, Währinger Straße 38, A-1090 Vienna (Austria)

    2015-03-25

    Highlights: • The method enables relative quantitation of hAGP glycans from pathological samples • Pancreatic cancer samples clearly showed an increase of hAGP fucosylated glycans. • Fucosylated glycans could be potential biomarkers for diagnosing pancreatic cancer. • The established method could be extremely useful to find novel glycoprotein biomarkers - Abstract: In this work we demonstrate the potential of glycan reductive isotope labeling (GRIL) using [{sup 12}C]- and [{sup 13}C]-coded aniline and zwitterionic hydrophilic interaction capillary liquid chromatography electrospray mass spectrometry (μZIC-HILIC-ESI-MS) for relative quantitation of glycosylation variants in selected glycoproteins present in samples from cancer patients. Human α{sub 1}-acid-glycoprotein (hAGP) is an acute phase serum glycoprotein whose glycosylation has been described to be altered in cancer and chronic inflammation. However, it is not clear yet whether some particular glycans in hAGP can be used as biomarker for differentiating between these two pathologies. In this work, hAGP was isolated by immunoaffinity chromatography (IAC) from serum samples of healthy individuals and from those suffering chronic pancreatitis and different stages of pancreatic cancer, respectively. After de-N-glycosylation, relative quantitation of the hAGP glycans was carried out using stable isotope labeling and μZIC-HILIC-ESI-MS analysis. First, protein denaturing conditions prior to PNGase F digestion were optimized to achieve quantitative digestion yields, and the reproducibility of the established methodology was evaluated with standard hAGP. Then, the proposed method was applied to the analysis of the clinical samples (control vs. pathological). Pancreatic cancer samples clearly showed an increase in the abundance of fucosylated glycans as the stage of the disease increases and this was unlike to samples from chronic pancreatitis. The results gained here indicate the mentioned glycan in h

  13. Quantitative analysis of N-glycans from human alfa-acid-glycoprotein using stable isotope labeling and zwitterionic hydrophilic interaction capillary liquid chromatography electrospray mass spectrometry as tool for pancreatic disease diagnosis

    International Nuclear Information System (INIS)

    Highlights: • The method enables relative quantitation of hAGP glycans from pathological samples • Pancreatic cancer samples clearly showed an increase of hAGP fucosylated glycans. • Fucosylated glycans could be potential biomarkers for diagnosing pancreatic cancer. • The established method could be extremely useful to find novel glycoprotein biomarkers - Abstract: In this work we demonstrate the potential of glycan reductive isotope labeling (GRIL) using [12C]- and [13C]-coded aniline and zwitterionic hydrophilic interaction capillary liquid chromatography electrospray mass spectrometry (μZIC-HILIC-ESI-MS) for relative quantitation of glycosylation variants in selected glycoproteins present in samples from cancer patients. Human α1-acid-glycoprotein (hAGP) is an acute phase serum glycoprotein whose glycosylation has been described to be altered in cancer and chronic inflammation. However, it is not clear yet whether some particular glycans in hAGP can be used as biomarker for differentiating between these two pathologies. In this work, hAGP was isolated by immunoaffinity chromatography (IAC) from serum samples of healthy individuals and from those suffering chronic pancreatitis and different stages of pancreatic cancer, respectively. After de-N-glycosylation, relative quantitation of the hAGP glycans was carried out using stable isotope labeling and μZIC-HILIC-ESI-MS analysis. First, protein denaturing conditions prior to PNGase F digestion were optimized to achieve quantitative digestion yields, and the reproducibility of the established methodology was evaluated with standard hAGP. Then, the proposed method was applied to the analysis of the clinical samples (control vs. pathological). Pancreatic cancer samples clearly showed an increase in the abundance of fucosylated glycans as the stage of the disease increases and this was unlike to samples from chronic pancreatitis. The results gained here indicate the mentioned glycan in hAGP as a candidate

  14. Liquid chromatography-electrospray-tandem mass spectrometry method for determination of organophosphate diesters in biotic samples including Great Lakes herring gull plasma.

    Science.gov (United States)

    Su, Guanyong; Greaves, Alana K; Gauthier, Lewis; Letcher, Robert J

    2014-12-29

    Environmentally relevant organophosphate (OP) triester flame retardants are known to degrade to OP diester phosphoric acids. In this study, a quantitatively sensitive method was developed for OP diesters in biological samples of varying complexity, bovine serum, chicken egg homogenate and pork liver. Fortified with 1ng or 10ng each of the six OP diester and six OP triester standards, samples were extracted by accelerated solvent extraction that completely separated OP diesters and triesters. OP diester fractions were cleaned up using weak anion exchange solid phase extraction and eluted with high ionic strength ammonium acetate buffer. Optimal analysis of chlorinated OP diesters was via decamethonium hydroxide dicationic reagent derivatization and by LC-ESI(+)-MS/MS, and for all non-chlorinated OP diesters by non-derivatized LC-ESI(-)-MS/MS. Except for derivatization LC-ESI(+)-MS/MS analysis of liver, at the 10ng spiking level for the three matrices, recovery efficiencies, matrix effects and method limits of quantification (MLOQs) of OP diesters ranged from 55-116%, 92-119%, and 0.02-0.31ng/g wet weight (ww) respectively. Plasma samples of n=6 herring gulls (2010, Chantry Is., Laurentian Great Lakes) contained triphenyl phosphate and tris(1-3-dichloro-2-propyl) phosphate ranging from 1.3 to 4.0ng/g ww and

  15. Ethyl glucuronide in vitreous humor and blood postmortem specimens: analysis by liquid chromatography-electrospray tandem mass spectrometry and interpreting results of neo-formation of ethanol

    Directory of Open Access Journals (Sweden)

    Sara Vezzoli

    2015-03-01

    Full Text Available Introduction. The determination of ethyl glucuronide (EtG, a stable and sensitive marker that is specific to alcohol intake, finds many applications both in the forensic toxicology and clinical fields. Aim. The aim of the study is to examine the possibility of using a cadaveric biological matrix, vitreous humor (VH, to determine EtG as a marker of recent ethanol use. Methods. The blood, taken from the femoral vein, and the VH were obtained from 63 autopsy cases. Analysis of the EtG was performed using an LC/MS/MS system. Analyses of the ethanol and putrefaction biomarkers, such as acetaldehyde and n-propanol, were performed using the HS-GC/FID technique in both the matrices. Results. In 17 cases, both ethanol and EtG were absent in both matrices.Nineteen cases presented ethanol in blood from 0.05 to 0.30 g/L, EtG-Blood concentration from 0.02 to 3.27 mg/L, and EtG-VH concentration from 0.01 mg/L to 2.88 mg/L. Thirteen cases presented ethanol in blood > 0.05 g/L but EtG concentration in blood and VH lower than 0.01 mg/L, are part of these 8 samples presented acetic aldehyde and n- propanol in blood or VH, means identification of putrefaction indicators. Fourteen cases presented ethanol in blood > 0.46 and EtG concentration in blood and VH higher than 0.01 mg/L. Conclusions. The determination of EtG in biological material is important in those cases where the intake of ethanol appears doubtful, as it allows us to exclude the possibility of any post-mortem formation of ethanol.

  16. Ethyl glucuronide in vitreous humor and blood postmortem specimens: analysis by liquid chromatography-electrospray tandem mass spectrometry and interpreting results of neo-formation of ethanol

    OpenAIRE

    Sara Vezzoli; Marzia Bernini; Francesco De Ferrari

    2015-01-01

    Introduction. The determination of ethyl glucuronide (EtG), a stable and sensitive marker that is specific to alcohol intake, finds many applications both in the forensic toxicology and clinical fields. Aim. The aim of the study is to examine the possibility of using a cadaveric biological matrix, vitreous humor (VH), to determine EtG as a marker of recent ethanol use. Methods. The blood, taken from the femoral vein, and the VH were obtained from 63 autopsy cases. Analysis of the EtG was perf...

  17. Quantification of the Triazole Antifungal Compounds Voriconazole and Posaconazole in Human Serum or Plasma Using Liquid Chromatography Electrospray Tandem Mass Spectrometry (HPLC-ESI-MS/MS).

    Science.gov (United States)

    Molinelli, Alejandro R; Rose, Charles H

    2016-01-01

    Voriconazole and posaconazole are triazole antifungal compounds used in the treatment of fungal infections. Therapeutic drug monitoring of both compounds is recommended in order to guide drug dosing to achieve optimal blood concentrations. In this chapter we describe an HPLC-ESI-MS/MS method for the quantification of both compounds in human plasma or serum following a simple specimen preparation procedure. Specimen preparation consists of protein precipitation using methanol and acetonitrile followed by a cleanup step that involves filtration through a cellulose acetate membrane. The specimen is then injected into an HPLC-ESI-MS/MS equipped with a C18 column and separated over an acetonitrile gradient. Quantification of the drugs in the specimen is achieved by comparing the response of the unknown specimen to that of the calibrators in the standard curve using multiple reaction monitoring. PMID:26660172

  18. Ion-pairing reversed-phase liquid chromatography/electrospray ionization mass spectrometric analysis of 76 underivatized amino acids of biological interest: a new tool for the diagnosis of inherited disorders of amino acid metabolism.

    Science.gov (United States)

    Piraud, Monique; Vianey-Saban, Christine; Petritis, Konstantinos; Elfakir, Claire; Steghens, Jean-Paul; Bouchu, Denis

    2005-01-01

    Seventy-six molecules of biological interest for the diagnosis of inherited disorders of amino acids (AA) metabolism have previously been demonstrated to be detectable in electrospray ionization tandem mass spectrometry (ESI-MS/MS) positive mode without derivatization. Reversed-phase liquid chromatography (RPLC) separation on different C18 columns using various perfluorinated carboxylic acids as ion-pairing agents has been found suitable for coupling with MS/MS, and for the separation of AA. A new procedure was optimized in order to replace the usual ion-exchange chromatographic, post-column ninhydrin derivatization, time-consuming routine method. This procedure allowed an adequate separation of all the molecules from other known interfering compounds, and a throughput of two samples per hour. Quantification limits for each molecule were found to be compatible with their measurement in plasma and urine. We validated the qualitative part of the method by analyzing plasma and urine samples from patients affected with several inherited disorders of AA metabolism. We validated the quantification of 16 AA using their stable isotopes as internal standard. The calibration curves were linear over the range 0-3 mM. The quantitative results obtained with the new method on 105 plasma and 99 urine samples were in good agreement with those obtained by the established routine method. Spiking experiments and precision results were also satisfactory. PMID:15915446

  19. Optimization of the Extraction of Anthocyanins from the Fruit Skin of Rhodomyrtus tomentosa (Ait. Hassk and Identification of Anthocyanins in the Extract Using High-Performance Liquid Chromatography-Electrospray Ionization-Mass Spectrometry (HPLC-ESI-MS

    Directory of Open Access Journals (Sweden)

    Yuan-Ming Sun

    2012-05-01

    Full Text Available Anthocyanins are naturally occurring polyphenols that impart bright color to fruits, vegetables and plants. In this study, the extraction of anthocyanins from freeze-dried fruit skin of downy rose-myrtle (Rhodomyrtus tomentosa (Ait. Hassk var. Gangren was optimized using response surface methodology (RSM. Using 60% ethanol containing 0.1% (v/v hydrochloric acid as extraction solvent, the optimal conditions for maximum yields of anthocyanin (4.358 ± 0.045 mg/g were 15.7:1 (v/w liquid to solid ratio, 64.38 °C with a 116.88 min extraction time. The results showed good fits with the proposed model for the anthocyanin extraction (R2 = 0.9944. Furthermore, the results of high-performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS analysis of the anthocyanins extracted from the fruit skin of downy rose-myrtle revealed the presence of five anthocyanin components, which were tentatively identified as delphinidin-3-glucoside, cyanidin-3-glucoside, peonidin-3-glucoside, petunidin-3-glucoside and malvidin-3-glucoside.

  20. Liquid chromatographic-mass spectrometric analysis of glucuronide-conjugated anabolic steroid metabolites: method validation and interlaboratory comparison

    NARCIS (Netherlands)

    Hintikka, L.; Kuuranne, T.; Leinonen, A.; Thevis, M.; Schanzer, W.; Halket, J.; Cowan, D.; Grosse, J.; Hemmersbach, P.; Nielen, M.W.F.; Kostiainen, R.

    2008-01-01

    Liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method for simultaneous and direct detection of 12 glucuronide-conjugated anabolic androgenic steroid (AAS) metabolites in human urine is described. The compounds selected were the main metabolites detected in huma

  1. Ultra performance liquid chromatography tandem mass spectrometry performance evaluation for analysis of antibiotics in natural waters.

    Science.gov (United States)

    Tamtam, Fatima; Mercier, Fabien; Eurin, Joëlle; Chevreuil, Marc; Le Bot, Barbara

    2009-03-01

    An ultra performance liquid chromatography electrospray tandem mass spectrometry (UPLC/MS/MS) method was developed and validated for the determination of 17 antibiotics in natural waters in one single extraction and chromatographic procedure. Gradient separation conditions were optimised for 17 compounds belonging to five different antibiotic groups: quinolones (oxolinic acid, nalidixic acid, pipemidic acid, flumequine), fluoroquinolones (enoxacin, ciprofloxacin, norfloxacin, ofloxacin, enrofloxacin, sarafloxacin, danofloxacin, difloxacin, lomefloxacin), sulphonamides (sulphamethoxazole, sulphamethazine), nitro-imidazole (ornidazole) and diaminopyrimidine (trimethoprim). The separation of all compounds, obtained using a 1.7 microm particle size column (100 mm x 2.1 mm), was achieved within 10 min time. Water samples were adjusted to pH 7 and extracted using Oasis hydrophilic-lipophilic balance (HLB) solid phase extraction cartridges. After elution with methanol and concentration, extracts were injected in a C18 column (Acquity UPLC BEH C18) and detected by tandem mass spectrometry. Average recovery from 100 ng L(-1) fortified samples was higher than 70% for most of the compounds, with relative standard deviations below 20%. Performances of the method (recoveries, detection limit, quantification limit and relative standard deviation) and matrix effects were studied, and results obtained showed that method was suitable for routine analysis of antibiotics in surface water. Samples analysis from Seine River (France) confirmed the interest of antibiotic contamination evaluation in that area. PMID:19148627

  2. Simultaneous determination of seven flavonoids in Epimedium by liquid chromatography-tandem mass spectrometry method

    Institute of Scientific and Technical Information of China (English)

    Cai Sheng Wu; Bao Lin Guo; Yu Xin Sheng; Jin Lan Zhang

    2008-01-01

    In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoids, namely epimedin A, epimedin B, epimedin C, icariin, sagittatoside B, 2"-0-rhamnosyl icariside II, and baohuoside I in Epimedium from different sources.

  3. Glycerophospholipid analysis of Eastern red bat (Lasiurus borealis) hair by electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Pannkuk, Evan L; McGuire, Liam P; Gilmore, David F; Savary, Brett J; Risch, Thomas S

    2014-03-01

    Pilosebaceous units found in the mammalian integument are composed of a hair follicle, the proximal portion of the hair shaft, a sebaceous gland, and the erector pili muscle. Pilosebaceous units release protective oils, or sebum, by holocrine secretion onto skin and hair through rupturing of sebocytes. Sebum is composed largely of polar and neutral lipids including glycerolipids, free fatty acids, sterols, wax esters, sterol esters, and squalene. In addition to these lipid classes, there is a small proportion of ionic/anionic glycerophospholipids (GPs). Composition of GPs on hair is rarely addressed despite their broad biological activities as signaling molecules and membrane stability. Furthermore, knowledge on GP composition in bats is lacking. Bat GP composition is important to document due to GP roles ranging from decreasing drag during migration to interaction with the integumentary microbiome. In this study, we analyzed GP molecular composition with liquid chromatography electrospray ionization tandem mass spectrometry and compared GP content to previous literature. A total of 152 GPs were detected. Broad GP classes identified include lysophosphatidylcholine, phosphatidylcholine (PC), lysophosphatidylethanolamine, phosphatidylethanolamine, phosphatidylinositol, phosphatidylserine, phosphatidic acid, and phosphatidylglycerol, with PC being the most abundant class. The acyl components were consistent with fatty acid methyl esters and triacylglyceride moieties found in Eastern red bat sebum. Glycerophospholipid proportions of the hair surface were different from a previous study on bat lung surfactants. This study determined the broad class and molecular species of bat sebum GPs that may be used in future ecological studies in vespertilionid bats. PMID:24532214

  4. Analysis of meat samples for anabolic steroids residues by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Blasco, Cristina; Van Poucke, Christof; Van Peteghem, Carlos

    2007-06-22

    A rapid, specific and highly sensitive multi-residue method for the determination of anabolic steroid residues in bovine, pork and poultry muscle tissues was developed. The sample preparation involves enzymatic digestion followed by extraction with methanol. The crude extract was cleaned up by solid-phase extraction (SPE) combining C18 and NH2 columns. The detection was carried out by a highly sensitive liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method using both positive and negative ionization modes. Natural and synthetic steroids covering different polarities could be extracted, concentrated and purified using one single method. Mobile phase composition and additives were optimized to achieve the highest sensitivity. The linearity was not good enough for quantitative analysis but the method was well-suited for qualitative confirmation. The method was validated according to the European Commission Decision 2002/657/EC. Decision limits (CCalpha) and detection capabilities (CCbeta) were below 0.5 ng g(-1) for all the compounds in the three types of meat studied. The developed method is suitable for routine analysis in our laboratories. PMID:17459396

  5. [Determination of five synthetic sweeteners in wines using high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Ji, Chao; Feng, Feng; Chen, Zhengxing; Sun, Li; Chu, Xiaogang

    2010-08-01

    A high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI MS/MS) method for the determination of five synthetic sweeteners (acesulfame, sodium saccharin, sodium cyclamate, aspartame and neotame) in wines has been developed. The HPLC separation was carried out on an Ultimate C18 column (100 mm x 2.1 mm, 3 microm). Several parameters, including the composition and pH of the mobile phase, column temperature and the monitor ions, were optimized for improving the chromatographic performance and the sensitivity of determination. The results demonstrated that the separation can be completed in less than 5 min by gradient elution with 20 mmol/L ammonium formate and 0.1% (v/v) formic acid (pH 3.8) and methanol as the mobile phase. The column temperature was kept at 45 degrees C. When the analytes were detected by ESI -MS/MS under multiple reaction monitoring mode, the detection limits were 0.6, 5, 1, 0.8 and 0.2 microg/L for acesulfame, sodium saccharin, sodium cyclamate, aspartame and neotame, respectively. The average recoveries ranged from 87.2% to 103%. The relative standard deviations were not more than 1.2%. This method is rapid, accurate, highly sensitive and suitable for the quality control of low concentration of the synthetic sweeteners, which are illegally added to wines and other foods with complex matrices. PMID:21261041

  6. Peptide profiling of Internet-obtained Cerebrolysin using high performance liquid chromatography - electrospray ionization ion trap and ultra high performance liquid chromatography - ion mobility - quadrupole time of flight mass spectrometry.

    Science.gov (United States)

    Gevaert, Bert; D'Hondt, Matthias; Bracke, Nathalie; Yao, Han; Wynendaele, Evelien; Vissers, Johannes Petrus Cornelis; De Cecco, Martin; Claereboudt, Jan; De Spiegeleer, Bart

    2015-09-01

    Cerebrolysin, a parenteral peptide preparation produced by controlled digestion of porcine brain proteins, is an approved nootropic medicine in some countries. However, it is also easily and globally available on the Internet. Nevertheless, until now, its exact chemical composition was unknown. Using high performance liquid chromatography (HPLC) coupled to ion trap and ultra high performance liquid chromatography (UHPLC) coupled to quadrupole-ion mobility-time-of-flight mass spectrometry (Q-IM-TOF MS), combined with UniProt pig protein database search and PEAKS de novo sequencing, we identified 638 unique peptides in an Internet-obtained Cerebrolysin sample. The main components in this sample originate from tubulin alpha- and beta-chain, actin, and myelin basic protein. No fragments of known neurotrophic factors like glial cell-derived neurotrophic factor (GDNF), neurotrophin nerve growth factor (NGF), brain-derived neurotrophic factor (BDNF), and ciliary neurotrophic factor (CNTF) were found, suggesting that the activities reported in the literature are likely the result of new, hitherto unknown cryptic peptides with nootropic properties. PMID:26017115

  7. Expediting the method development and quality control of reversed-phase liquid chromatography electrospray ionization mass spectrometry for pharmaceutical analysis by using an LC/MS performance test mix.

    Science.gov (United States)

    Tang, L; Fitch, W L; Alexander, M S; Dolan, J W

    2000-11-01

    Mass spectrometry combined with liquid chromatography (LC/MS) has become an important analytical methodology in both pharmaceutical and biomolecule analyses. LC/MS, especially with reversed-phase HPLC (RP-LC), is extensively used in the separation and structural identification of pharmaceutical samples. However, many parameters have to be considered when a new LC/MS method is developed for either separation and structural analysis of unknown mixtures or quantitative analysis of a set of known compounds in an assay. The optimization of a new LC/MS method can be a time-consuming process. A novel kit-LC/MS performance test mix-composed of aspartame, cortisone, reserpine, and dioctyl phthalate has been developed to accelerate the process of establishing a new RP-LC/MS method. The LC/MS mix makes the evaluation and validation of an LC/MS method more efficient and easier. It also simplifies the quality control procedure for an LC/MS method in use. PMID:11080866

  8. Mass spectrometry by means of tandem accelerators

    International Nuclear Information System (INIS)

    Mass spectrometry based on an accelerator allows to measure rare cosmogenic isotopes found in natural samples with isotopic abundances up to 10E-15. The XTU Tandem of Legnaro National Laboratories can measure mean heavy isotopes (36Cl, 41Ca, 129I) in applications interesting cosmochronology and Medicine. The TTT-3 Tandem of the Naples University has been modified in view of precision studies of C14 in Archeology, Paleantology and Geology. In this paper a review is made of principles and methodologies and of some applicationy in the framework of the National Program for mass spectrametry research with the aid of accelerators

  9. [Determination of three sweeteners in vinegars by solid phase extraction-high performance liquid chromatography/tandem mass spectrometry].

    Science.gov (United States)

    Yin, Feng; Ding, Zhaowei; Cao, Xue; Gao, Jie; Jiang, Deming; Kuang, Denghui; Gu, Yanping; He, Guoliang

    2011-06-01

    A solid phase extraction-high performance liquid chromatography/electrospray ionization-tandem mass spectrometry (SPE-HPLC/ESI-MS/MS) method for the determination of 3 sweeteners (acesulfame (AK), sodium saccharin (SA), sodium cyclamate (SC)) in vinegars has been developed. The sample was diluted with acidic water, then purified and enriched with a weak anion exchange SPE column. The HPLC separation was performed on a Pursuit C18 column (150 mm x 2.0 mm, 3 microm) by gradient elution with 10 mmol/L ammonium acetate containing 0.1% (v/v) ammonia water and acetonitrile as the mobile phases. The analytes were detected by ESI--MS/MS in multiple reaction monitoring (MRM) mode to satisfy qualitative and quantitative detections. Good linearities (r2 > 0.99) were obtained over the range of 0.01 - 0.50 mg/L. The limits of quantification (LOQs) for SA, AK and SC were 10, 5 and 5 microg/kg, respectively. The average recoveries ranged from 72.1% to 96.8% at the spiked levels of 0.01 and 0.1 mg/L with the relative standard deviations (RSDs) less than 15%. This method is accurate, highly sensitive for qualitative and quantitative analysis of the 3 sweeteners in vinegars. PMID:22032168

  10. Identification of Glioblastoma Phosphotyrosine-Containing Proteins with Two-Dimensional Western Blotting and Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Tianyao Guo

    2015-01-01

    Full Text Available To investigate the presence of, and the potential biological roles of, protein tyrosine phosphorylation in the glioblastoma pathogenesis, two-dimensional gel electrophoresis- (2DGE- based Western blotting coupled with liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS analysis was used to detect and identify the phosphotyrosine immunoreaction-positive proteins in a glioblastoma tissue. MS/MS and Mascot analyses were used to determine the phosphotyrosine sites of each phosphopeptide. Protein domain and motif analysis and systems pathway analysis were used to determine the protein domains/motifs that contained phosphotyrosine residue and signal pathway networks to clarify the potential biological functions of protein tyrosine phosphorylation. A total of 24 phosphotyrosine-containing proteins were identified. Each phosphotyrosine-containing protein contained at least one tyrosine kinase phosphorylation motif and a certain structural and functional domains. Those phosphotyrosine-containing proteins were involved in the multiple signal pathway systems such as oxidative stress, stress response, and cell migration. Those data show 2DGE-based Western blotting, MS/MS, and bioinformatics are a set of effective approaches to detect and identify glioblastoma tyrosine-phosphorylated proteome and to effectively rationalize the biological roles of tyrosine phosphorylation in the glioblastoma biological systems. It provides novel insights regarding tyrosine phosphorylation and its potential role in the molecular mechanism of a glioblastoma.

  11. Simultaneous Determination and Pharmacokinetic Study of Protocatechuic Aldehyde and Its Major Active Metabolite Protocatechuic Acid in Rat Plasma by Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Wang, Xiangyang; Yan, Kaijing; Ma, Xiaohui; Li, Wei; Chu, Yang; Guo, Jiahua; Li, Shuming; Zhou, Shuiping; Zhu, Yonghong; Liu, Changxiao

    2016-05-01

    A very simple and selective high-performance liquid chromatography electrospray ionization tandem mass spectrometry (LC-MS-MS) method was developed for simultaneous determination and pharmacokinetic study of protocatechuic aldehyde (PAL) and its active metabolite protocatechuic acid (PCA). The method involves a simple liquid-liquid extraction with ethyl acetate. The separation was performed on a Hypersil GOLD C18column (2.1 × 150 mm, 3.0 µm; particle, Thermo, USA) with isocratic elution using a mobile phase consisted of methanol and water (containing 0.1% formic acid) at a flow rate of 0.2 mL/min. The detection of target compounds was done by using low-energy collision dissociation tandem mass spectrometry (CID-MS-MS) using the selective reaction monitoring scan mode. The method was linear for all analytes over the investigated range for all correlation coefficients greater than 0.9950. The lower limits of quantification were 2.0 ng/mL for PAL and PCA. The intra- and interday precisions (relative standard deviation, RSD %) were <6.84 and 5.54%, and the accuracy (relative error, RE %) was between -2.85 and 0.74% (n= 6). The developed method was applied to study the pharmacokinetics of PAL and its major active metabolite PCA in rat plasma after oral and intravenous administration of PAL. PMID:26969682

  12. Conversion of 3-nitrotyrosine to 3-aminotyrosine residues facilitates mapping of tyrosine nitration in proteins by electrospray ionization-tandem mass spectrometry using electron capture dissociation.

    Science.gov (United States)

    Guo, Jia; Prokai, Laszlo

    2012-12-01

    Protein tyrosine nitration is associated with oxidative stress and various human diseases. Tandem mass spectrometry has been the method of choice for the identification and localization of this posttranslational modification to understand the underlying mechanisms and functional consequences. Due to the electron predator effect of the nitro group limiting fragmentation of the peptide backbone, electron-based dissociation has not been applicable, however, to nitrotyrosine-containing peptides. A straightforward conversion of the nitrotyrosine to the aminotyrosine residues is introduced to address this limitation. When tested with nitrated ubiquitin and human serum albumin as model proteins in top-down and bottom-up approaches, respectively, this chemical derivatization enhanced backbone fragmentation of the corresponding nitroproteins and nitropeptides by electron capture dissociation (ECD). Increased sequence coverage has been obtained by combining in the bottom-up strategy the conversion of nitrotyrosine to aminotyrosine and introducing, in addition to trypsin, a further digesting enzyme of complementary specificity, when protein nitration was mapped by liquid chromatography-electrospray ionization tandem mass spectrometry using both collision-induced dissociation (CID) and ECD. PMID:23280749

  13. High Mass Accuracy Phosphopeptide Identification Using Tandem Mass Spectra

    OpenAIRE

    Sadygov, Rovshan G.

    2012-01-01

    Phosphoproteomics is a powerful analytical platform for identification and quantification of phosphorylated peptides and assignment of phosphorylation sites. Bioinformatics tools to identify phosphorylated peptides from their tandem mass spectra and protein sequence databases are important part of phosphoproteomics. In this work, we discuss general informatics aspects of mass-spectrometry-based phosphoproteomics. Some of the specifics of phosphopeptide identifications stem from the labile nat...

  14. Oxidation of Intracellular and Extracellular Fatty Acids in Skeletal Muscle: Application of kinetic modeling, stable isotopes and liquid chromatography/electrospray ionization ion-trap tandem mass spectrometry technology

    OpenAIRE

    Xu, J; Zhou, L.; Persson, X-M.; Balagopal, P.; Jensen, M D; Guo, ZK.

    2008-01-01

    Fatty acids are a major fuel for many tissues and abnormal utilization is implicated in diseases. However, tissue fatty acid oxidation has not been determined reliably in vivo. Furthermore, fatty acid oxidation has not been partitioned into intracellular and extracellular components. In this report, a one-pool model is described that enables direct quantitation of fluxes of intracellular and plasma fatty acids to mitochondria in skeletal muscle using dual stable isotopes and liquid chromatogr...

  15. Characterization of gallotannins from Astronium species by flow injection analysis- electrospray ionization-ion trap-tandem mass spectrometry and matrix-assisted laser desorption/ionization time-of- flight mass spectrometry.

    Science.gov (United States)

    da Silva, Viviane Cândida; Napolitano, Assunta; Eletto, Daniela; Rodrigues, Clenilson Martins; Pizza, Cosimo; Vilegas, Wagner

    2011-01-01

    The species Astronium urundeuva (Allemao) Engl. and Astronium graveolens Jacq., which are used in Brazilian folk medicine to treat allergies, inflammation, diarrhea and ulcers, were investigated for their composition. The aim of this study was to define a rapid and reliable analytical approach, based on the flow-injection analysis-electrospray ionization-ion trap-tandem mass spectrometry (FIA-ESI-IT-MS-MS) and matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-ToF-MS), to investigate the full range of hydrolyzable tannins present in the extracts of these Astronium species. The MALDI-ToF-MS analysis allowed us to ascertain the presence of hydrolysable tannins in both Astronium species as a series of gallotannins with degrees of polymerization of 7 to 13 galloyl units. Moreover, the analysis by FIA-ESI-IT-MS-MS, as well as confirming this result and chemically defining gallotannins as galloylglucose compounds, highlighted the presence of further classes of hydrolysable tannins, such as hexahydrodiphenoyl esters of glucose and some gallic acid derivatives, providing information about their structure by a careful study of their fragmentation patterns. Finally, the evaluation of the number of positional isomers of gallotannins occurring in both Astronium species was obtained by high-performance liquid chromatography-electrospray ionization-ion trap mass spectrometry (HPLC/ESI-IT-MS). This is the first mass spectrometric evidence relating to the existence of gallotannins in Astronium genus. PMID:22006629

  16. Determination of chloramphenicol, thiamphenicol, florfenicol and florfenicol amine in poultry, swine, bovine and fish by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Barreto, Fabiano; Ribeiro, Cristina; Barcellos Hoff, Rodrigo; Dalla Costa, Teresa

    2016-06-01

    A simple, rapid and sensitive method for confirmatory and quantitative purposes using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) was developed and validated for determination of chloramphenicol, thiamphenicol, florfenicol and its metabolite, florfenicol amine, in poultry, swine, bovine and fish muscle. Sample preparation was based on extraction with organic solvent (ethyl acetate: ammonium hydroxide, 98:2) followed by evaporation and fat removal using hexane. The chromatographic separation was carried out with an XTerra C18 column with a gradient elution using water and acetonitrile both with 2mM of ammonium acetate. Mass spectrometry with electrospray ionization was operated in positive or negative polarity using selected-reaction monitoring (SRM) analysis mode, achieving the requirements of four identification points for each compound. Chloramphenicol-D5 was added as internal standard. Method validation was performed according to the criteria of Commission Decision 2002/657/EC. Parameters as precision, reproducibility, trueness, CCα and CCβ were determined. Trueness values were within the range 82-108% and 84-111% for bovine and fish, respectively. Precision ranged from 1.1% to 10.1% and within-laboratory reproducibility ranged from 4.3 to 18.1%, depending on matrix. The CCα and CCβ for bovine muscle, for instance, were established as 0.06 and 0.11μgkg(-1), respectively. The method was successfully applied for several interlaboratory proficiency testing programs, achieving 100% of satisfactory results. PMID:27133862

  17. Structural Characterization of New Peptide Variants Produced by Cyanobacteria from the Brazilian Atlantic Coastal Forest Using Liquid Chromatography Coupled to Quadrupole Time-of-Flight Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Miriam Sanz

    2015-06-01

    Full Text Available Cyanobacteria from underexplored and extreme habitats are attracting increasing attention in the search for new bioactive substances. However, cyanobacterial communities from tropical and subtropical regions are still largely unknown, especially with respect to metabolite production. Among the structurally diverse secondary metabolites produced by these organisms, peptides are by far the most frequently described structures. In this work, liquid chromatography/electrospray ionization coupled to high resolution quadrupole time-of-flight tandem mass spectrometry with positive ion detection was applied to study the peptide profile of a group of cyanobacteria isolated from the Southeastern Brazilian coastal forest. A total of 38 peptides belonging to three different families (anabaenopeptins, aeruginosins, and cyanopeptolins were detected in the extracts. Of the 38 peptides, 37 were detected here for the first time. New structural features were proposed based on mass accuracy data and isotopic patterns derived from full scan and MS/MS spectra. Interestingly, of the 40 surveyed strains only nine were confirmed to be peptide producers; all of these strains belonged to the order Nostocales (three Nostoc sp., two Desmonostoc sp. and four Brasilonema sp..

  18. A strategy for identification and structural characterization of compounds from Gardenia jasminoides by integrating macroporous resin column chromatography and liquid chromatography-tandem mass spectrometry combined with ion-mobility spectrometry.

    Science.gov (United States)

    Wang, Lu; Liu, Shu; Zhang, Xueju; Xing, Junpeng; Liu, Zhiqiang; Song, Fengrui

    2016-06-24

    In this paper, an analysis strategy integrating macroporous resin (AB-8) column chromatography and high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) combined with ion mobility spectrometry (IMS) was proposed and applied for identification and structural characterization of compounds from the fruits of Gardenia jasminoides. The extracts of G. jasminoides were separated by AB-8 resin column chromatography combined with reversed phase liquid chromatography (C18 column) and detected by electrospray ionization tandem mass spectrometry. Additionally, ion mobility spectrometry (IMS) was employed as a supplementary separation technique to discover previously undetected isomers from the fruits of G. jasminoides. A total of 71 compounds, including iridoids, flavonoids, triterpenes, monoterpenoids, carotenoids and phenolic acids were identified by the characteristic high resolution mass spectrometry and the ESI-MS/MS fragmentations. In conclusion, the IMS-MS technique achieved the separation of isomers in crocin-3 and crocin-4 according to their acquired mobility drift times differing from classical analysis by mass spectrometry. The proposed strategy can be used as a highly sensitive and efficient procedure for identification and separation isomeric components in extracts of herbal medicines. PMID:27208986

  19. Liquid Chromatography Tandem Mass Spectrometry Method for Quantification of Solifenacin in Human Plasma and its Application to Bioequivalence Study

    Directory of Open Access Journals (Sweden)

    Nishant Paliwal

    2013-06-01

    Full Text Available A hasty, specific and robust assay based on liquid-liquid extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI MS-MS has been developed and validated for the quantitative analysis of Solifenacin ( a drug used for urinary incontinence in human plasma using Solifenacin D5 as internal standard (ISTD. The precursor to product ion transitions of m/z 363.20/110.10 and m/z 368.14/110.20 were used to measure the analyte and the ISTD, respectively. The method was validated in terms of selectivity, matrix effect, sensitivity, linearity, precision and accuracy, various stabilities (standard stock solution stability in refrigerator and at room temperature, stock dilution stability at refrigerator and room temperature, auto sampler stability, freeze thaw stability, long term stability- 65 o C ± 10o C & long term stability- 22 o C ± 5°C, reagent stability, bench top stability, dry extract stability, wet extract stability in refrigerator, effect of potentially interfering drugs, dilution integrity, recovery, lon suppression through infusion, and blood Stability. The mean percentage recovery of Solifenacin and the internal standard was 65.39 ± 3.646% and 66.24 ± 2.209% respectively. The assay exhibited a linear dynamic range of 0.200 to 30.361 ng mL-1. The RSD % of intra-day and inter-day assay was ≤15%. The application of this assay was demonstrated in a bioequivalence study and will be ideal for clinical pharmacokinetic studies in study population with as lower as 0.200 ng mL-1 analytical sensitivity and as little as 300 μL plasma sample.

  20. Rapid determination of phenoxy acid residues in rice by modified QuEChERS extraction and liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    A new method for the analysis of phenoxy acid herbicide residues in rice, based on the use of liquid extraction/partition and dispersive solid phase extraction (dispersive-SPE) followed by ultra-performance liquid chromatography-electrospray ionization tandem mass spectrometry (UPLC-ESI-MS/MS), is reported. 5% (v/v) formic acid in acetonitrile as the extraction solvent and inclusion of citrate buffer helped partitioning of all the analytes into the acetonitrile phase. The extract was then cleaned up by dispersive-SPE using C18 and alumina neutral as selective sorbents. Further optimization of sample preparation and determination allowed recoveries of between 45 and 104% for all 13 phenoxy acid herbicides with RSD values lower than 13.3% at 5.0 μg kg-1 concentration level. Limit of detections (LODs) of 0.5 μg kg-1 or below were attained for all 13 phenoxy acids. Quantitative analysis was done in the multiple-reaction monitoring (MRM) mode using two combinations of selected precursor ion and product ion transition for each compound. This developed method produced relatively higher recoveries of the acid herbicides with a smaller range of variation and less susceptibility to matrix effects, than the original QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) method

  1. Comparative study of different fabric phase sorptive extraction sorbents to determine emerging contaminants from environmental water using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lakade, Sameer S; Borrull, Francesc; Furton, Kenneth G; Kabir, Abuzar; Fontanals, Núria; Marcé, Rosa Maria

    2015-11-01

    A new sorptive extraction technique, fabric phase sorptive extraction (FPSE), using different coating chemistries: non-polar sol-gel poly(dimethyldiphenylsiloxane) (PDMDPS), medium polar sol-gel poly(tetrahydrofuran) (PTHF), and polar sol-gel poly(ethylene glycol)-block-poly(propylene glycol)-block-poly(ethylene glycol) (PEG-PPG-PEG triblock) and sol-gel Carbowax 20 M were evaluated to extract a group of pharmaceuticals and personal care products (PPCPs) with wide range of polarity from environmental aqueous samples. Different parameters affecting FPSE such as sample pH, stirring speed, addition of salt, extraction time, sample volume, elution solvent and desorption time were optimized for each sorbent coated FPSE media. Under optimum conditions, FPSE media coated with sol-gel Carbowax 20 M provided the highest absolute recoveries (77-85%) for majority of the analytes with the exception of the most polar ones. Nevertheless, all four sorbents offered better recovery compared to the commercially available coating for stir-bar sorptive extraction based on Ethylene Glycol/Silicone (EG/Silicone). The method based on FPSE with sol-gel Carbowax 20 M media and liquid chromatography-(electrospray ionization) tandem mass spectrometry (LC-(ESI) MS/MS) was developed and validated for environmental water samples. Good apparent recoveries (41-80%), detection limits (1-50 ng L(-1)), repeatability (%RSD<15%, n=5) and reproducibility (%RSD<18%, n=5) were achieved. PMID:26452968

  2. Simultaneous determination of drugs of abuse and their main metabolites using pressurized liquid extraction and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Arbeláez, Paula; Borrull, Francesc; Maria Marcé, Rosa; Pocurull, Eva

    2014-07-01

    An analytical method based on pressurized liquid extraction (PLE) and liquid chromatography-(electrospray)-tandem mass spectrometry was developed for the simultaneous determination of nicotine, four drugs of abuse (opiates and alkaloids) and four of their main metabolites in sewage sludge. The optimum PLE conditions were: cell volume 11 mL, dichloromethane as extraction solvent, 5 min preheating time, 100 °C temperature, 1500 psi pressure, 60% flush volume, 1 cycle, 15 min static extraction time, 120 s purge time and sample weight 1g. Absolute recoveries for all compounds were between 25% and 65%. Data acquisition was done by selective reaction monitoring and the two most abundant product ions were used for confirmation. Limits of detection were lower than 10 μg/kg dry weight (d.w.) and limits of quantification were between 2.5 and 25 μg/kg (d.w.). The highest concentrations found in sludge samples from two sewage treatment plants were for nicotine and cocaine in the range of 23-173 μg/kg (d.w.) and 9-232 μg/kg (d.w.) respectively. PMID:24840416

  3. Detection of triclocarban and two co-contaminating chlorocarbanilides in US aquatic environments using isotope dilution liquid chromatography tandem mass spectrometry

    International Nuclear Information System (INIS)

    The antimicrobial compound triclocarban (TCC; 3,4,4'-trichlorocarbanilide; CAS-bar 101-20-2) is a high-production-volume chemical, recently suggested to cause widespread contamination of US water resources. To test this hypothesis, we developed an isotope dilution liquid chromatography electrospray ionization tandem mass spectrometry method for ultratrace analysis of TCC (0.9ng/L detection limit) and analyzed low-volume water samples (200mL) along with primary sludge samples from across the United States. All river water samples (100%) collected downstream of wastewater treatment plants had detectable levels of TCC, as compared to 56% of those taken upstream. Concentrations of TCC (mean+/-standard deviation) downstream of sewage treatment plants (84+/-110ng/L) were significantly higher (Pw/w each) in technical grade TCC (99%). Application of the new method for chlorocarbanilide analysis yielded TCC occurrence data for 13 US states, confirmed the role of sewage treatment plants as environmental inputs of TCC, and identified DCC and TetraCC as previously unrecognized pollutants released into the environment alongside TCC

  4. Multiplex liquid chromatography-tandem mass spectrometry for the detection of wheat, oat, barley and rye prolamins towards the assessment of gluten-free product safety.

    Science.gov (United States)

    Manfredi, Anita; Mattarozzi, Monica; Giannetto, Marco; Careri, Maria

    2015-10-01

    Celiac patients should feel confident in the safety of foods labelled or expected to be gluten-free. In this context, a targeted proteomic approach based on liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) technique was proposed to assess the presence of celiotoxic cereals, namely wheat, oats, barley and rye, in raw and processed food products. To this aim, unique marker peptides were properly selected in order to distinguish between the different cereal types. A revised cocktail solution based on reducing and denaturing agents was exploited for prolamin extraction from raw and processed food; in addition, defatting with hexane was carried out for sample clean-up, allowing to largely reduce problems related to matrix effect. Method validation on fortified rice flour showed good analytical performance in terms of sensitivity (limits of detection in the 2-18 mg kg(-1) range). However, poor trueness was calculated for self-made incurred bread (between 3 and 30% depending on the peptide), probably due to baking processes, which reduce gluten extractability. Thus, it is evident that in the case of processed foods further insights into sample treatment efficiency and reference materials for protein calibration are required to obtain accurate gluten determination. Finally, the developed method was applied for the analysis of market food products, offering the possibility to discriminate among cereals, with good agreement with labelled ingredients for gluten-containing foodstuffs. PMID:26454460

  5. High Mass Accuracy Phosphopeptide Identification Using Tandem Mass Spectra

    Directory of Open Access Journals (Sweden)

    Rovshan G. Sadygov

    2012-01-01

    Full Text Available Phosphoproteomics is a powerful analytical platform for identification and quantification of phosphorylated peptides and assignment of phosphorylation sites. Bioinformatics tools to identify phosphorylated peptides from their tandem mass spectra and protein sequence databases are important part of phosphoproteomics. In this work, we discuss general informatics aspects of mass-spectrometry-based phosphoproteomics. Some of the specifics of phosphopeptide identifications stem from the labile nature of phosphor groups and expanded peptide search space. Allowing for modifications of Ser, Thr, and Tyr residues exponentially increases effective database size. High mass resolution and accuracy measurements of precursor mass-to-charge ratios help to restrict the search space of candidate peptide sequences. The higher-order fragmentations of neutral loss ions enhance the fragment ion mass spectra of phosphorylated peptides. We show an example of a phosphopeptide identification where accounting for fragmentation from neutral loss species improves the identification scores in a database search algorithm by 50%.

  6. An integrated strategy for rapid and accurate determination of free and cell-bound microcystins and related peptides in natural blooms by liquid chromatography-electrospray-high resolution mass spectrometry and matrix-assisted laser desorption/ionization time-of-flight/time-of-flight mass spectrometry using both positive and negative ionization modes.

    Science.gov (United States)

    Flores, Cintia; Caixach, Josep

    2015-08-14

    An integrated high resolution mass spectrometry (HRMS) strategy has been developed for rapid and accurate determination of free and cell-bound microcystins (MCs) and related peptides in water blooms. The natural samples (water and algae) were filtered for independent analysis of aqueous and sestonic fractions. These fractions were analyzed by MALDI-TOF/TOF-MS and ESI-Orbitrap-HCD-MS. MALDI, ESI and the study of fragmentation sequences have been provided crucial structural information. The potential of combined positive and negative ionization modes, full scan and fragmentation acquisition modes (TOF/TOF and HCD) by HRMS and high resolution and accurate mass was investigated in order to allow unequivocal determination of MCs. Besides, a reliable quantitation has been possible by HRMS. This composition helped to decrease the probability of false positives and negatives, as alternative to commonly used LC-ESI-MS/MS methods. The analysis was non-target, therefore covered the possibility to analyze all MC analogs concurrently without any pre-selection of target MC. Furthermore, archived data was subjected to retrospective "post-targeted" analysis and a screening of other potential toxins and related peptides as anabaenopeptins in the samples was done. Finally, the MS protocol and identification tools suggested were applied to the analysis of characteristic water blooms from Spanish reservoirs. PMID:26141269

  7. Optimized verification method for detection of an albumin-sulfur mustard adduct at Cys(34) using a hybrid quadrupole time-of-flight tandem mass spectrometer after direct plasma proteolysis.

    Science.gov (United States)

    John, Harald; Siegert, Markus; Gandor, Felix; Gawlik, Michael; Kranawetvogl, Andreas; Karaghiosoff, Konstantin; Thiermann, Horst

    2016-02-26

    The vesicant sulfur mustard (SM) is a banned chemical warfare agent that is controlled by the Organisation for the Prohibition of Chemical Weapons (OPCW). Bioanalytical procedures are mandatory for proving an alleged use and incorporation of SM into the body. We herein present the development and application of a novel optimized procedure suitable for qualitative verification analysis of plasma targeting the SM-adduct of human serum albumin (HSA) alkylated at the cysteine(34) residue. Diluted human plasma is directly mixed with pronase in an ultrafiltration device (10kDa cut-off) for proteolysis (4h, 37°C). Following ultrafiltration the filtrate is diluted and analyzed by microbore liquid chromatography-electrospray ionization high resolution tandem-mass spectrometry (μLC-ESI HR MS/MS) targeting the alkylated dipeptide hydroxyethylthioethyl-CysPro (HETE-CP). A hybrid quadrupole time-of-flight mass spectrometer provided high mass spectrometric resolution in the MS/MS mode enabling highest selectivity and sensitivity (lower limit of detection corresponding to 9.8nM SM in plasma). Kinetics of HETE-CP formation from heparin-, citrate-, and EDTA-plasma as well as serum are presented and the influence of different EDTA and pronase concentrations was characterized. The novel procedure was applied to plasma samples provided by the OPCW as well as to patientś plasma derived from real cases of SM-poisoning. PMID:26449527

  8. Economics of tandem mass spectrometry screening of neonatal inherited disorders

    OpenAIRE

    Pandor, A; Eastham, J.; Chilcott, J.; Paisley, S; Beverley, C.

    2006-01-01

    Objectives: The aim of this study was to evaluate the cost-effectiveness of neonatal screening for phenylketonuria (PKU) and medium-chain acyl-coA dehydrogenase (MCAD) deficiency using tandem mass spectrometry (tandem MS). Methods: A systematic review of clinical efficacy evidence and cost-effectiveness modeling of screening in newborn infants within a UK National Health Service perspective was performed. Marginal costs, life-years gained, and cost-effectiveness acceptability curves are p...

  9. Rapid and simple extraction of lipids from blood plasma and urine for liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Bang, Dae Young; Byeon, Seul Kee; Moon, Myeong Hee

    2014-02-28

    A simple and fast lipid extraction method from human blood plasma and urine is introduced in this study. The effective lipid extraction from biological systems with a minimization of the matrix effect is important for the successful qualitative and quantitative analysis of lipids in liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS). The method described here is based on the modification of the quick, easy, cheap, effective, rugged and safe (QuEChERS) extraction method, which was originally developed for pesticide residue analysis in food, for the purpose of isolating lipids from biological fluids. Applicability of QuEChERS method for lipids was evaluated by varying organic solvents for the extraction/partitioning of lipids in MgSO4/CH3COONa for the removal of water and by varying sorbents (primary secondary amines, graphitized carbon black, silica, strong anion exchange resins and C18 particles) for the dispersive solid-phase extraction (dSPE) step. This study shows that 2:1 (v/v) CHCl3/CH3OH is effective in the extraction/partitioning step and that 50mg of C18 particles (for 0.1mL plasma and 1mL of urine) are more suitable for sample cleanup for the dSPE step of the QuEChERS method. Matrix effects were calculated by comparing the recovery values of lipid standards spiked to both plasma and urine samples after extraction with those of the same standards in a neat solution using nanoflow LC-ESI-MS/MS, resulting in improved MS signals due to the decrease of the ion suppression compared to the conventional Folch method. The modified QuEChERS method was applied to lipid extracts from both human urine and plasma samples, demonstrating that it can be powerfully utilized for high-speed (<15min) preparation of lipids compared to the Folch method, with equivalent or slightly improved results in lipid identification using nLC-ESI-MS/MS. PMID:24491523

  10. Development, validation, and application of a liquid chromatography-tandem mass spectrometry method for the determination of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol in human hair.

    Science.gov (United States)

    Yao, Li; Yang, Jun; Guan, Ya-feng; Liu, Bai-zhan; Zheng, Sai-jing; Wang, Wei-miao; Zhu, Xiao-lan; Zhang, Zhi-dan

    2012-11-01

    The tobacco-specific nitrosamine metabolite 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) is a valuable biomarker for human exposure to the carcinogenic nitrosamine 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) in tobacco and tobacco smoke. In this work, an efficient and sensitive method for the analysis of NNAL in human hair was developed and validated. The hair sample was extracted by NaOH solution digestion, purified by C(18) solid-phase extraction (SPE) and molecularly imprinted solid-phase extraction, further enriched by reverse-phase ultrasound-assisted dispersive liquid-liquid microextraction (USA-DLLME) into 1.0 % aqueous formic acid, and finally analyzed by liquid chromatography-electrospray ionization tandem mass spectrometry. Good linearity was obtained in the range of 0.24-10.0 pg/mg hair with a correlation coefficient of 0.9982, when 150 mg hair was analyzed. The limit of detection and lower limit of quantification were 0.08 and 0.24 pg/mg hair, respectively. Accuracies determined from hair samples spiked with three different levels of NNAL ranged between 87.3 and 107.7 %. Intra- and inter-day relative standard deviations varied from 4.1 to 8.5 % and from 6.9 to 11.3 %, respectively. Under the optimized conditions, an enrichment factor of 20 was obtained. Finally, the developed method was applied for the analysis of NNAL in smokers' hair. The proposed sample preparation procedure combining selectivity of two-step SPE and enrichment of DLLME significantly improves the purification and enrichment of the analyte and should be useful to analyze NNAL in hair samples for cancer risk evaluation and cancer prevention in relation to exposure to the tobacco-specific carcinogen NNK. PMID:22926132

  11. Hydrophilic interaction liquid chromatography-tandem mass spectrometry quantitative method for the cellular analysis of varying structures of gemini surfactants designed as nanomaterial drug carriers.

    Science.gov (United States)

    Donkuru, McDonald; Michel, Deborah; Awad, Hanan; Katselis, George; El-Aneed, Anas

    2016-05-13

    Diquaternary gemini surfactants have successfully been used to form lipid-based nanoparticles that are able to compact, protect, and deliver genetic materials into cells. However, what happens to the gemini surfactants after they have released their therapeutic cargo is unknown. Such knowledge is critical to assess the quality, safety, and efficacy of gemini surfactant nanoparticles. We have developed a simple and rapid liquid chromatography electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method for the quantitative determination of various structures of gemini surfactants in cells. Hydrophilic interaction liquid chromatography (HILIC) was employed allowing for a short simple isocratic run of only 4min. The lower limit of detection (LLOD) was 3ng/mL. The method was valid to 18 structures of gemini surfactants belonging to two different structural families. A full method validation was performed for two lead compounds according to USFDA guidelines. The HILIC-MS/MS method was compatible with the physicochemical properties of gemini surfactants that bear a permanent positive charge with both hydrophilic and hydrophobic elements within their molecular structure. In addition, an effective liquid-liquid extraction method (98% recovery) was employed surpassing previously used extraction methods. The analysis of nanoparticle-treated cells showed an initial rise in the analyte intracellular concentration followed by a maximum and a somewhat more gradual decrease of the intracellular concentration. The observed intracellular depletion of the gemini surfactants may be attributable to their bio-transformation into metabolites and exocytosis from the host cells. Obtained cellular data showed a pattern that grants additional investigations, evaluating metabolite formation and assessing the subcellular distribution of tested compounds. PMID:27086283

  12. Determination of melamine in milk-based products and other food and beverage products by ion-pair liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ibanez, Maria; Sancho, Juan V. [Research Institute for Pesticides and Water, University Jaume I, E-12071, Castellon (Spain); Hernandez, Felix, E-mail: felix.hernandez@qfa.uji.es [Research Institute for Pesticides and Water, University Jaume I, E-12071, Castellon (Spain)

    2009-09-01

    This paper describes a fast method for the sensitive and selective determination of melamine in a wide range of food matrices, including several milk-based products. The method involves an extraction with aqueous 1% trichloroacetic acid before the injection of the 10-fold diluted extract into the liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) system, using labelled melamine as the internal standard. As melamine is present in aqueous media in the cationic form, the chromatographic separation in reversed-phase LC requires the use of anionic ion-pair reagents, such as tridecafluoroheptanoic acid (THFA). This allows a satisfactory chromatographic retention and peak shape in all the types of food samples investigated. The method has been validated in six food matrices (biscuit, dry pasta and four milk-based products) by means of recovery experiments in samples spiked at 1 and 5 mg kg{sup -1}. Average recoveries (n = 5) ranged from 77% to 100%, with excellent precision (RSDs lower than 5%) and limits of detection between 0.01 and 0.1 mg kg{sup -1}. In addition, accuracy and robustness of the method was proven in different soya-based matrices by means of quality control (QC) sample analysis. QC recoveries, at 1 and 2.5 mg kg{sup -1}, were satisfactory, ranging from 79% to 110%. The method developed in this work has been applied to the determination of melamine in different types of food samples. All detections were confirmed by acquiring two MS/MS transitions (127 > 85 for quantification; 127 > 68 for confirmation) and comparing their ion intensity ratio with that of reference standards. Accuracy of the method was also assessed by applying it to a milk-based product and a baking mix material as part of an EU proficiency test, in which highly satisfactory results were obtained.

  13. Determination of melamine in milk-based products and other food and beverage products by ion-pair liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    This paper describes a fast method for the sensitive and selective determination of melamine in a wide range of food matrices, including several milk-based products. The method involves an extraction with aqueous 1% trichloroacetic acid before the injection of the 10-fold diluted extract into the liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) system, using labelled melamine as the internal standard. As melamine is present in aqueous media in the cationic form, the chromatographic separation in reversed-phase LC requires the use of anionic ion-pair reagents, such as tridecafluoroheptanoic acid (THFA). This allows a satisfactory chromatographic retention and peak shape in all the types of food samples investigated. The method has been validated in six food matrices (biscuit, dry pasta and four milk-based products) by means of recovery experiments in samples spiked at 1 and 5 mg kg-1. Average recoveries (n = 5) ranged from 77% to 100%, with excellent precision (RSDs lower than 5%) and limits of detection between 0.01 and 0.1 mg kg-1. In addition, accuracy and robustness of the method was proven in different soya-based matrices by means of quality control (QC) sample analysis. QC recoveries, at 1 and 2.5 mg kg-1, were satisfactory, ranging from 79% to 110%. The method developed in this work has been applied to the determination of melamine in different types of food samples. All detections were confirmed by acquiring two MS/MS transitions (127 > 85 for quantification; 127 > 68 for confirmation) and comparing their ion intensity ratio with that of reference standards. Accuracy of the method was also assessed by applying it to a milk-based product and a baking mix material as part of an EU proficiency test, in which highly satisfactory results were obtained.

  14. Interpretation of Tandem Mass Spectrometry (MSMS) Spectra for Peptide Analysis

    DEFF Research Database (Denmark)

    Hjernø, Karin; Højrup, Peter

    2015-01-01

    The aim of this chapter is to give a short introduction to peptide analysis by mass spectrometry (MS) and interpretation of fragment mass spectra. Through examples and guidelines we demonstrate how to understand and validate search results and how to perform de novo sequencing based on the often...... very complex fragmentation pattern obtained by tandem mass spectrometry (also referred to as MSMS). The focus is on simple rules for interpretation of MSMS spectra of tryptic as well as non-tryptic peptides....

  15. Analysis of major antioxidants from extracts of Myrmecodia pendans by UV/visible spectrophotometer, liquid chromatography/tandem mass spectrometry, and high-performance liquid chromatography/UV techniques

    Directory of Open Access Journals (Sweden)

    Adam Mekonnen Engida

    2015-06-01

    Full Text Available In the present work, heat reflux extraction with ethanol/water (80:20; v/v as the solvent was used to extract antioxidants from Myrmecodia pendans. The crude extract (CE was fractionated using hexane and ethyl acetate. Ethyl acetate fraction (EAF and aqueous fraction were collected. Antioxidant activity against 1,1-diphenyl-2-picrylhydrazyl-radical radical and ferric reducing power of the CE, EAF, and aqueous fraction were evaluated. EAF showed comparable antioxidant activity against 1,1-diphenyl-2-picrylhydrazyl-radical radical and ferric reducing power to those of the CE. UV/visible, liquid chromatography/electrospray ionization/tandem mass spectrometry, and high-performance liquid chromatography were employed for identifying the major antioxidant compounds in the EAF. Three major phenolic compounds (rosmarinic acid, procyanidin B1, and polymer of procyanidin B1 were identified. The first two compounds were confirmed and quantified by high-performance liquid chromatography using authentic standards, but confirmation of the third compound was hampered by a lack of commercial standard. Concentrations of rosmarinic acid and procyanidin B1 in the EAF were found to be 20.688 ± 1.573 mg/g dry sample and 3.236 ± 0.280 mg/g dry sample, respectively. All these three compounds are reported for the first time in sarang semut.

  16. Quantification of oxidative DNA lesions in tissues of Long-Evans Cinnamon rats by capillary high-performance liquid chromatography-tandem mass spectrometry coupled with stable isotope-dilution method.

    Science.gov (United States)

    Wang, Jin; Yuan, Bifeng; Guerrero, Candace; Bahde, Ralf; Gupta, Sanjeev; Wang, Yinsheng

    2011-03-15

    The purpose of our study was to develop suitable methods to quantify oxidative DNA lesions in the setting of transition metal-related diseases. Transition metal-driven Fenton reactions constitute an important endogenous source of reactive oxygen species (ROS). In genetic diseases with accumulation of transition metal ions, excessive ROS production causes pathophysiological changes, including DNA damage. Wilson's disease is an autosomal recessive disorder with copper toxicosis due to deficiency of ATP7B protein needed for excreting copper into bile. The Long-Evans Cinnamon (LEC) rat bears a deletion in Atp7b gene and serves as an excellent model for hepatic Wilson's disease. We used a sensitive capillary liquid chromatography-electrospray-tandem mass spectrometry (LC-ESI-MS/MS/MS) method in conjunction with the stable isotope-dilution technique to quantify several types of oxidative DNA lesions in the liver and brain of LEC rats. These lesions included 5-formyl-2'-deoxyuridine, 5-hydroxymethyl-2'-deoxyuridine, and the 5'R and 5'S diastereomers of 8,5'-cyclo-2'-deoxyguanosine and 8,5'-cyclo-2'-deoxyadenosine. Moreover, the levels of these DNA lesions in the liver and brain increased with age and correlated with age-dependent regulation of the expression of DNA repair genes in LEC rats. These results provide significant new knowledge for better understanding the implications of oxidative DNA lesions in transition metal-induced diseases, such as Wilson's disease, as well as in aging and aging-related pathological conditions. PMID:21323344

  17. Peptide Identification by Tandem Mass Spectrometry with Alternate Fragmentation Modes*

    OpenAIRE

    Guthals, Adrian; Bandeira, Nuno

    2012-01-01

    The high-throughput nature of proteomics mass spectrometry is enabled by a productive combination of data acquisition protocols and the computational tools used to interpret the resulting spectra. One of the key components in mainstream protocols is the generation of tandem mass (MS/MS) spectra by peptide fragmentation using collision induced dissociation, the approach currently used in the large majority of proteomics experiments to routinely identify hundreds to thousands of proteins from s...

  18. Structural Characterization of Carbohydrates by Fourier Transform Tandem Mass Spectrometry

    OpenAIRE

    Zhou, Wen; Håkansson, Kristina

    2011-01-01

    Fourier transform tandem mass spectrometry (MS/MS) provides high mass accuracy, high sensitivity, and analytical versatility and has therefore emerged as an indispensable tool for structural elucidation of biomolecules. Glycosylation is one of the most common posttranslational modifications, occurring in ~50% of proteins. However, due to the structural diversity of carbohydrates, arising from non-template driven biosynthesis, achievement of detailed structural insight is highly challenging. T...

  19. Analysis of posttranslational modifications of proteins by tandem mass spectrometry

    DEFF Research Database (Denmark)

    Larsen, Martin Røssel; Trelle, Morten B; Thingholm, Tine E;

    2006-01-01

    -temporal distribution in cells and tissues. Most PTMs can be detected by protein and peptide analysis by mass spectrometry (MS), either as a mass increment or a mass deficit relative to the nascent unmodified protein. Tandem mass spectrometry (MS/MS) provides a series of analytical features that are highly useful for......Protein activity and turnover is tightly and dynamically regulated in living cells. Whereas the three-dimensional protein structure is predominantly determined by the amino acid sequence, posttranslational modification (PTM) of proteins modulates their molecular function and the spatial...

  20. Interpretation of collision-induced fragmentation tandem mass spectra of posttranslationally modified peptides

    DEFF Research Database (Denmark)

    Bunkenborg, Jakob; Matthiesen, Rune

    2007-01-01

    Tandem collision-induced dissociation (CID) mass spectrometry (MS) provides a sensitive means of analyzing the amino acid sequence of peptides. Modern MS instrumentation is capable of rapidly generating many thousands of tandem mass spectra, and protein database search engines have been developed...... validating low-energy CID tandem mass spectra and gives some useful tables to aid this process....

  1. Identification of phenolic compounds in strawberries by liquid chromatography electrospray ionization mass spectroscopy

    OpenAIRE

    Seeram, Navindra P.; Lee, R; Scheuller, H S; Heber, D

    2006-01-01

    Strawberry (Fragaria x ananassa Duch.) fruits contain phenolic compounds that have antioxidant, anticancer, antiatherosclerotic and anti-neurodegenerative properties. Identification of food phenolics is necessary since their nature, size, solubility, degree and position of glycosylation and conjugation influence their absorption, distribution, metabolism and excretion in humans. Freeze-dried whole strawberry fruit powder and strawberry fruit extracts were analyzed by liquid chromatography ele...

  2. Multiresidue Analysis of Seven Anticoagulant Rodenticides by high-performance liquid chromatography/electrospray/mass spectrometry

    Science.gov (United States)

    Mice and rat populations are commonly controlled by two classes of rodenticide anticoagulants, coumarins and indandiones. However, poisoning of nontarget animals also often occurs. For cases such as these, a rapid, multi-residue method, which provides positive confirmation for both classes of antico...

  3. Determination of neonicotinoids in Estonian honey by liquid chromatography-electrospray mass spectrometry.

    Science.gov (United States)

    Laaniste, Asko; Leito, Ivo; Rebane, Riin; Lõhmus, Rünno; Lõhmus, Ants; Punga, Fredrik; Kruve, Anneli

    2016-07-01

    The aim of the study was to provide a comprehensive overview of neonicotinoid pesticide residues in honey samples for a single country and compare the results with the import data for neonicotinoid pesticides. The levels of four neonicotinoid pesticides, namely thiamethoxam, imidacloprid, acetamiprid, and thiacloprid, were determined in 294 honey samples harvested from 2005 to 2013 from more than 200 locations in Estonia. For the analyzed honey samples, 27% contained thiacloprid, and its levels in all cases were below the maximum residue level set by the European Union. The other neonicotinoids were not detected. The proportion of thiacloprid-positive samples for different years correlates well with the data on thiacloprid imports into Estonia, indicating that honey contamination with neonicotinoids can be estimated based on the import data. PMID:27050772

  4. Validation and use of a fast sample preparation method and liquid chromatography-tandem mass spectrometry in analysis of ultra-trace levels of 98 organophosphorus pesticide and carbamate residues in a total diet study involving diversified food types.

    Science.gov (United States)

    Chung, Stephen W C; Chan, Benny T P

    2010-07-16

    This paper reports a comprehensive sensitive multi-residue liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for detection, identification and quantitation of 73 pesticides and their related products, a total of 98 analytes, belonging to organophosphorus pesticides (OPPs) and carbamates, in foods. The proposed method makes use of a modified QuEChERS (quick, easy, cheap, effective, rigged, and safe) procedure that combines isolation of the pesticides and sample clean-up in a single step. Analysis is performed by liquid chromatography-electrospray ionization-tandem mass spectrometry operated in the multiple reaction monitoring (MRM) mode, acquiring two specific precursor-product ion transitions per target compound. Two main fragment ions for each pesticide were obtained to achieve the identification according to the SANCO guidelines 10684/2009. The method was validated with various food samples, including edible oil, meat, egg, cheese, chocolate, coffee, rice, tree nuts, citric fruits, vegetables, etc. No significant matrix effect was observed for tested pesticides, therefore, matrix-matched calibration was not necessary. Calibration curves were linear and covered from 1 to 20 microg L(-1) for all compounds studied. The average recoveries, measured at 10 microg kg(-1), were in the range 70-120% for all of the compounds tested with relative standard deviations below 20%, while a value of 10 microg kg(-1) has been established as the method limit of quantitation (MLOQ) for all target analytes. Similar trueness and precision results were also obtained for spiking at 200 microg kg(-1). Expanded uncertainty values were in the range 21-27% while the HorRat ratios were below 1. The method has been successfully applied to the analysis of 700 food samples in the course of a baseline monitoring study of OPPs and carbamates. PMID:20557892

  5. Automatic Validation of Phosphopeptide Identifications from Tandem Mass Spectra

    OpenAIRE

    Lu, Bingwen; Ruse, Cristian; Xu, Tao; Park, Sung Kyu; Yates, John

    2007-01-01

    We developed and compared two approaches for automated validation of phosphopeptides tandem mass spectra identified using database searching algorithms. Phosphopeptide identifications were obtained through SEQUEST searches of a protein database appended with its decoy (reversed sequences). Statistical evaluation and iterative searches were employed to create a high quality dataset of phosphopeptides. Automation of post-search validation was approached by two different strategies. By using sta...

  6. Tandem mass spectrometry data quality assessment by self-convolution

    Directory of Open Access Journals (Sweden)

    Tham Wai

    2007-09-01

    Full Text Available Abstract Background Many algorithms have been developed for deciphering the tandem mass spectrometry (MS data sets. They can be essentially clustered into two classes. The first performs searches on theoretical mass spectrum database, while the second based itself on de novo sequencing from raw mass spectrometry data. It was noted that the quality of mass spectra affects significantly the protein identification processes in both instances. This prompted the authors to explore ways to measure the quality of MS data sets before subjecting them to the protein identification algorithms, thus allowing for more meaningful searches and increased confidence level of proteins identified. Results The proposed method measures the qualities of MS data sets based on the symmetric property of b- and y-ion peaks present in a MS spectrum. Self-convolution on MS data and its time-reversal copy was employed. Due to the symmetric nature of b-ions and y-ions peaks, the self-convolution result of a good spectrum would produce a highest mid point intensity peak. To reduce processing time, self-convolution was achieved using Fast Fourier Transform and its inverse transform, followed by the removal of the "DC" (Direct Current component and the normalisation of the data set. The quality score was defined as the ratio of the intensity at the mid point to the remaining peaks of the convolution result. The method was validated using both theoretical mass spectra, with various permutations, and several real MS data sets. The results were encouraging, revealing a high percentage of positive prediction rates for spectra with good quality scores. Conclusion We have demonstrated in this work a method for determining the quality of tandem MS data set. By pre-determining the quality of tandem MS data before subjecting them to protein identification algorithms, spurious protein predictions due to poor tandem MS data are avoided, giving scientists greater confidence in the

  7. A workflow for multiclass determination of 256 pesticides in essential oils by liquid chromatography tandem mass spectrometry using evaporation and dilution approaches: Application to lavandin, lemon and cypress essential oils.

    Science.gov (United States)

    Fillatre, Yoann; Rondeau, David; Daguin, Antoine; Communal, Pierre-Yves

    2016-03-01

    This paper describes the determination of 256 multiclass pesticides in cypress and lemon essential oils (EOs) by the way of liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) analysis using the scheduled selected reaction monitoring mode (sSRM) available on a hybrid quadrupole linear ion trap (QLIT) mass spectrometer. The performance of a sample preparation of lemon and cypress EOs based on dilution or evaporation under nitrogen assisted by a controlled heating were assessed. The best limits of quantification (LOQs) were achieved with the evaporation under nitrogen method giving LOQs≤10µgL(-1) for 91% of the pesticides. In addition the very satisfactory results obtained for recovery, repeatability and linearity showed that for EOs of relatively low evaporation temperature, a sample preparation based on evaporation under nitrogen is well adapted and preferable to dilution. By compiling these results with those previously published by some of us on lavandin EO, we proposed a workflow dedicated to multiresidue determination of pesticides in various EOs by LC-ESI/sSRM. Among the steps involved in this workflow, the protocol related to mass spectrometry proposes an alternative confirmation method to the classical SRM ratio criteria based on a sSRM survey scan followed by an information-dependent acquisition using the sensitive enhanced product ion (EPI) scan to generate MS/MS spectra then compared to a reference. The submitted workflow was applied to the case of lemon EOs samples highlighting for the first time the simultaneous detection of 20 multiclass pesticides in one EO. Some pesticides showed very high concentration levels with amounts greatly exceeding the mgL(-1). PMID:26717829

  8. Use of specific peptide biomarkers for quantitative confirmation of hidden allergenic peanut proteins Ara h 2 and Ara h 3/4 for food control by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Careri, M; Costa, A; Elviri, L; Lagos, J-B; Mangia, A; Terenghi, M; Cereti, A; Garoffo, L Perono

    2007-11-01

    A liquid chromatography-electrospray-tandem mass spectrometry (LC-ESI-MS-MS) method based on the detection of biomarker peptides from allergenic proteins was devised for confirming and quantifying peanut allergens in foods. Peptides obtained from tryptic digestion of Ara h 2 and Ara h 3/4 proteins were identified and characterized by LC-MS and LC-MS-MS with a quadrupole-time of flight mass analyzer. Four peptides were chosen and investigated as biomarkers taking into account their selectivity, the absence of missed cleavages, the uniform distribution in the Ara h 2 and Ara h 3/4 protein isoforms together with their spectral features under ESI-MS-MS conditions, and good repeatability of LC retention time. Because of the different expression levels, the selection of two different allergenic proteins was proved to be useful in the identification and univocal confirmation of the presence of peanuts in foodstuffs. Using rice crisp and chocolate-based snacks as model food matrix, an LC-MS-MS method with triple quadrupole mass analyzer allowed good detection limits to be obtained for Ara h 2 (5 microg protein g(-1) matrix) and Ara h 3/4 (1 microg protein g(-1) matrix). Linearity of the method was established in the 10-200 microg g(-1) range of peanut proteins in the food matrix investigated. Method selectivity was demonstrated by analyzing tree nuts (almonds, pecan nuts, hazelnuts, walnuts) and food ingredients such as milk, soy beans, chocolate, cornflakes, and rice crisp. PMID:17899033

  9. Interpretation of tandem mass spectra obtained from cyclic nonribosomal peptides.

    Science.gov (United States)

    Liu, Wei-Ting; Ng, Julio; Meluzzi, Dario; Bandeira, Nuno; Gutierrez, Marcelino; Simmons, Thomas L; Schultz, Andrew W; Linington, Roger G; Moore, Bradley S; Gerwick, William H; Pevzner, Pavel A; Dorrestein, Pieter C

    2009-06-01

    Natural and non-natural cyclic peptides are a crucial component in drug discovery programs because of their considerable pharmaceutical properties. Cyclosporin, microcystins, and nodularins are all notable pharmacologically important cyclic peptides. Because these biologically active peptides are often biosynthesized nonribosomally, they often contain nonstandard amino acids, thus increasing the complexity of the resulting tandem mass spectrometry data. In addition, because of the cyclic nature, the fragmentation patterns of many of these peptides showed much higher complexity when compared to related counterparts. Therefore, at the present time it is still difficult to annotate cyclic peptides MS/MS spectra. In this current work, an annotation program was developed for the annotation and characterization of tandem mass spectra obtained from cyclic peptides. This program, which we call MS-CPA is available as a web tool (http://lol.ucsd.edu/ms-cpa_v1/Input.py). Using this program, we have successfully annotated the sequence of representative cyclic peptides, such as seglitide, tyrothricin, desmethoxymajusculamide C, dudawalamide A, and cyclomarins, in a rapid manner and also were able to provide the first-pass structure evidence of a newly discovered natural product based on predicted sequence. This compound is not available in sufficient quantities for structural elucidation by other means such as NMR. In addition to the development of this cyclic annotation program, it was observed that some cyclic peptides fragmented in unexpected ways resulting in the scrambling of sequences. In summary, MS-CPA not only provides a platform for rapid confirmation and annotation of tandem mass spectrometry data obtained with cyclic peptides but also enables quantitative analysis of the ion intensities. This program facilitates cyclic peptide analysis, sequencing, and also acts as a useful tool to investigate the uncommon fragmentation phenomena of cyclic peptides and aids the

  10. Instruction manual for ORNL tandem high abundance sensitivity mass spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Smith, D.H.; McKown, H.S.; Chrisite, W.H.; Walker, R.L.; Carter, J.A.

    1976-06-01

    This manual describes the physical characteristics of the tandem mass spectrometer built by Oak Ridge National Laboratory for the International Atomic Energy Agency. Specific requirements met include ability to run small samples, high abundance sensitivity, good precision and accuracy, and adequate sample throughput. The instrument is capable of running uranium samples as small as 10/sup -12/ g and has an abundance sensitivity in excess of 10/sup 6/. Precision and accuracy are enhanced by a special sweep control circuit. Sample throughput is 6 to 12 samples per day. Operating instructions are also given.

  11. Non-Target Screening of Veterinary Drugs Using Tandem Mass Spectrometry on SmartMass

    Science.gov (United States)

    Xia, Bing; Liu, Xin; Gu, Yu-Cheng; Zhang, Zhao-Hui; Wang, Hai-Yan; Ding, Li-Sheng; Zhou, Yan

    2013-05-01

    Non-target screening of veterinary drugs using tandem mass spectrometric data was performed on the SmartMass platform. This newly developed software uses the characteristic fragmentation patterns (CFP) to identify chemicals, especially those containing particular substructures. A mixture of 17 sulfonamides was separated by ultra performance liquid chromatography (UPLC), and SmartMass was used to process the tandem mass spectrometry (MS/MS) data acquired on an Orbitrap mass spectrometer. The data were automatically extracted, and each sulfonamide was recognized and analyzed with a prebuilt analysis rule. By using this software, over 98 % of the false candidate structures were eliminated, and all the correct structures were found within the top 10 of the ranking lists. Furthermore, SmartMass could also be used to identify slightly modified contraband drugs and metabolites with simple prebuilt rules. [Figure not available: see fulltext.

  12. Quantitative Comparison of Tandem Mass Spectra Obtained on Various Instruments

    Science.gov (United States)

    Bazsó, Fanni Laura; Ozohanics, Oliver; Schlosser, Gitta; Ludányi, Krisztina; Vékey, Károly; Drahos, László

    2016-08-01

    The similarity between two tandem mass spectra, which were measured on different instruments, was compared quantitatively using the similarity index (SI), defined as the dot product of the square root of peak intensities in the respective spectra. This function was found to be useful for comparing energy-dependent tandem mass spectra obtained on various instruments. Spectral comparisons show the similarity index in a 2D "heat map", indicating which collision energy combinations result in similar spectra, and how good this agreement is. The results and methodology can be used in the pharma industry to design experiments and equipment well suited for good reproducibility. We suggest that to get good long-term reproducibility, it is best to adjust the collision energy to yield a spectrum very similar to a reference spectrum. It is likely to yield better results than using the same tuning file, which, for example, does not take into account that contamination of the ion source due to extended use may influence instrument tuning. The methodology may be used to characterize energy dependence on various instrument types, to optimize instrumentation, and to study the influence or correlation between various experimental parameters.

  13. Simultaneous determination of five phenolic components and paeoniflorin in rat plasma by liquid chromatography-tandem mass spectrometry and pharmacokinetic study after oral administration of Cerebralcare granule(®).

    Science.gov (United States)

    Wang, Xiang-yang; Ma, Xiao-hui; Li, Wei; Chu, Yang; Guo, Jia-hua; Li, Shu-ming; Wang, Jun-mei; Zhang, Hong-chao; Zhou, Shui-ping; Zhu, Yong-hong

    2013-12-01

    A simple, sensitive and selective high-performance liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method was developed for simultaneous determination and pharmacokinetic study of six active components, protocatechuic acid, chlorogenic acid, caffeic acid, ferulic acid rosmarinic acid and paeoniflorin in rat plasma after oral administration of Cerebralcare granule(®) for the first time. The method involves a simple liquid-liquid extraction with ethyl acetate. The separation was performed on a Luna C18 column (2.0×100mm i.d., 3.0μm, particle, Phenomenex, USA) with gradient elution using a mobile phase composed of acetonitrile and water (containing 0.1% formic acid) at a flow rate of 0.2ml/min. Electrospray ionization (ESI) in negative ion mode and selective reaction monitoring (SRM) was used for the quantification of six active components and internal standard (IS, Chloroamphenicol). The method was linear for all analytes over investigated range with all correlation coefficients greater than 0.9914. The lower limits of quantification (LLOQ) were 1.0ng/ml for protocatechuic acid, 1.0ng/ml for chlorogenic acid, 1.0ng/ml for caffeic acid, 5.0ng/ml for ferulic acid, 1.5ng/ml for rosmarinic acid and 6.0ng/ml for paeoniflorin, respectively. The intra- and inter-day precisions (R.S.D.%) were less than 6.60% and 11.68%, and accuracy (RE %) between -3.26% and 1.13% (n=6). The developed method was applied for the first time to the pharmacokinetic study of protocatechuic acid, chlorogenic acid, caffeic acid, ferulic acid, rosmarinic acid and paeoniflorin in rat plasma after oral administration of Cerebralcare granule(®). PMID:23994763

  14. Interpretation of tandem mass spectra of posttranslationally modified peptides

    DEFF Research Database (Denmark)

    Bunkenborg, J.; Matthiesen, R.

    2013-01-01

    spectra and protein database search engines have been developed to match the experimental data to peptide candidates. In most studies there is a schism between discarding perfectly valid data and including nonsensical peptide identifications-this is currently a major bottleneck in data-analysis and it...... calls for an understanding of tandem mass spectrometry data. Manual evaluation of the data and perhaps experimental cross-checking of the MS data can save many months of experimental work trying to do biological follow-ups based on erroneous identifications. Especially for posttranslationally modified...... peptides there is a need for manual validation of the data because search algorithms seldom have been optimized for the identification of modified peptides and because there are many pitfalls for the unwary. This chapter describes some of the issues that should be considered when interpreting and...

  15. TANDEM

    Data.gov (United States)

    Federal Laboratory Consortium — The Tandem Van de Graaff facility provides researchers with beams of more than 40 different types of ions - atoms that have been stripped of their electrons. One of...

  16. Mining tandem mass spectral data to develop a more accurate mass error model for peptide identification.

    Science.gov (United States)

    Fu, Yan; Gao, Wen; He, Simin; Sun, Ruixiang; Zhou, Hu; Zeng, Rong

    2007-01-01

    The assumption on the mass error distribution of fragment ions plays a crucial role in peptide identification by tandem mass spectra. Previous mass error models are the simplistic uniform or normal distribution with empirically set parameter values. In this paper, we propose a more accurate mass error model, namely conditional normal model, and an iterative parameter learning algorithm. The new model is based on two important observations on the mass error distribution, i.e. the linearity between the mean of mass error and the ion mass, and the log-log linearity between the standard deviation of mass error and the peak intensity. To our knowledge, the latter quantitative relationship has never been reported before. Experimental results demonstrate the effectiveness of our approach in accurately quantifying the mass error distribution and the ability of the new model to improve the accuracy of peptide identification. PMID:17990507

  17. Simulation of Two Dimensional Electrophoresis and Tandem Mass Spectrometry for Teaching Proteomics

    Science.gov (United States)

    Fisher, Amanda; Sekera, Emily; Payne, Jill; Craig, Paul

    2012-01-01

    In proteomics, complex mixtures of proteins are separated (usually by chromatography or electrophoresis) and identified by mass spectrometry. We have created 2DE Tandem MS, a computer program designed for use in the biochemistry, proteomics, or bioinformatics classroom. It contains two simulations--2D electrophoresis and tandem mass spectrometry.…

  18. Fast atom bombardment tandem mass spectrometry of carotenoids

    Energy Technology Data Exchange (ETDEWEB)

    van Breeman, R.B. [Univ. of Illinois, Chicago, IL (United States); Schmitz, H.H.; Schwartz, S.J. [North Carolina State Univ., Raleigh, NC (United States)

    1995-02-01

    Positive ion fast atom bombardment (FAB) tandem mass spectrometry (MS-MS) using a double-focusing mass spectrometer with linked scanning at constant B/E and high-energy collisionally activated dissociation (CAD) was used to differentiate 17 different cartenoids, including {beta}-apo-8{prime}- carotenal, astaxanthin, {alpha}-carotene, {beta}-carotene, {gamma}-carotene, {zeta}-carotene, canthaxanthin, {beta}-cryptoxanthin, isozeaxanthin bis (pelargonate), neoxanthin, neurosporene, nonaprene, lutein, lycopene, phytoene, phytofluene, and zeaxanthin. The carotenoids were either synthetic or isolated from plant tissues. The use of FAB ionization minimized degradation or rearrangement of the carotenoid structures due to the inherent thermal instability generally ascribed to these compounds. Instead of protonated molecules, both polar xanthophylls and nonpolar carotenes formed molecular ions, M{sup {center_dot}+}, during FAB ionization. Following collisionally activated dissociation, fragment ions of selected molecular ion precursors showed structural features indicative of the presence of hydroxyl groups, ring systems, ester groups, and aldehyde groups and the extent of aliphatic polyene conjugation. The fragmentation patterns observed in the mass spectra herein may be used as a reference for the structural determination of carotenoids isolated from plant and animal tissues. 18 refs., 4 figs.

  19. Identification of degradation products of indigoids by tandem mass spectrometry.

    Science.gov (United States)

    Witkoś, Katarzyna; Lech, Katarzyna; Jarosz, Maciej

    2015-11-01

    The study concerns identification of photodegradation products of indigotin, indirubin and isoindigo. Experimental methodology consists of degradation of standard solutions of indigoids in a solar box and analysis of samples taken at different aging time by using capillary high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometric and spectrophotometric detectors. Identification of the formed compounds was based on careful interpretation of the electrospray ionization MS/MS spectra. Apart from the well-known degradation products of indigoids: isatin, isatoic anhydride and anthranilic acid, another seven species were also identified, and their proposed structures were confirmed by high-resolution molecular masses measurements; according to the best knowledge of authors, they have not been reported so far. The obtained results formed the basis for postulating mechanism of the process. Moreover, the MRM (Multiple Reaction Monitoring) method was developed for the identification of natural dyes and their degradation products in textiles of historical value. Apart from such colorants as indigotin and flavonoids, also presence of degradation products of indigoids was confirmed. PMID:26505769

  20. A novel automated hydrophilic interaction liquid chromatography method using diode-array detector/electrospray ionization tandem mass spectrometry for analysis of sodium risedronate and related degradation products in pharmaceuticals.

    Science.gov (United States)

    Bertolini, Tiziana; Vicentini, Lorenza; Boschetti, Silvia; Andreatta, Paolo; Gatti, Rita

    2014-10-24

    A simple, sensitive and fast hydrophilic interaction liquid chromatography (HILIC) method using ultraviolet diode-array detector (UV-DAD)/electrospray ionization tandem mass spectrometry was developed for the automated high performance liquid chromatography (HPLC) determination of sodium risedronate (SR) and its degradation products in new pharmaceuticals. The chromatographic separations were performed on Ascentis Express HILIC 2.7μm (150mm×2.1mm, i.d.) stainless steel column (fused core). The mobile phase consisted of formate buffer solution (pH 3.4; 0.03M)/acetonitrile 42:58 and 45:55 (v/v) for granules for oral solution and effervescent tablet analysis, respectively, at a flow-rate of 0.2mL/min, setting the wavelength at 262nm. Stability characteristics of SR were evaluated by performing stress test studies. The main degradation product formed under oxidation conditions corresponding to sodium hydrogen (1-hydroxy-2-(1-oxidopyridin-3-yl)-1-phosphonoethyl)phosphonate was characterized by high performance liquid chromatography-electrospray ionization-mass tandem mass spectrometry (HPLC-ESI-MS/MS). The validation parameters such as linearity, sensitivity, accuracy, precision and selectivity were found to be highly satisfactory. Linear responses were observed in standard and in fortified placebo solutions. Intra-day precision (relative standard deviation, RSD) was ≤1.1% for peak area and ≤0.2% for retention times (tR) without significant differences between intra- and inter-day data. Recovery studies showed good results for all the examined compounds (from 98.7 to 101.0%) with RSD ranging from 0.6 to 0.7%. The limits of detection (LOD) and quantitation (LOQ) were 1 and 3ng/mL, respectively. The high stability of standard and sample solutions at room temperature means an undoubted advantage of the method allowing the simultaneous preparation of many samples and consecutive chromatographic analyses by using an autosampler. The developed stability indicating

  1. Identification of phenolic constituents in red chicory salads (Cichorium intybus) by high-performance liquid chromatography with diode array detection and electrospray ionisation tandem mass spectrometry.

    Science.gov (United States)

    Carazzone, Chiara; Mascherpa, Dora; Gazzani, Gabriella; Papetti, Adele

    2013-06-01

    Phenolic acids and flavonoids extracted from several types of Cichorium intybus var. silvestre salads ("Chioggia", "Treviso", "Treviso tardivo", and "Verona") were characterised by high-performance liquid chromatography-electrospray ionisation/mass spectrometry. Among the 64 compounds detected, several hydroxycinnamic acid derivatives including 8 mono- and dicaffeoylquinic acids, 3 tartaric acid derivatives, 31 flavonol and 2 flavone glycosides, as well as 10 anthocyanins were characterised based on UV spectra and MS(n) fragmentation patterns. Furthermore, several isomers of caffeic acid derivatives were distinguished for the first time by their specific mass spectral data. This is the first study reporting the glycosylation type and position of mono- and diglycosylated flavonoids in red salads. PMID:23411215

  2. A mass accuracy sensitive probability based scoring algorithm for database searching of tandem mass spectrometry data

    Directory of Open Access Journals (Sweden)

    Freitas Michael A

    2007-04-01

    Full Text Available Abstract Background Liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS has become one of the most used tools in mass spectrometry based proteomics. Various algorithms have since been developed to automate the process for modern high-throughput LC-MS/MS experiments. Results A probability based statistical scoring model for assessing peptide and protein matches in tandem MS database search was derived. The statistical scores in the model represent the probability that a peptide match is a random occurrence based on the number or the total abundance of matched product ions in the experimental spectrum. The model also calculates probability based scores to assess protein matches. Thus the protein scores in the model reflect the significance of protein matches and can be used to differentiate true from random protein matches. Conclusion The model is sensitive to high mass accuracy and implicitly takes mass accuracy into account during scoring. High mass accuracy will not only reduce false positives, but also improves the scores of true positive matches. The algorithm is incorporated in an automated database search program MassMatrix.

  3. Installation of a tandem-type accelerator mass spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mizushima, Toshihiko; Togawa, Orihiko; Mizutani, Yoshihiko [Japan Atomic Energy Research Inst., Mutsu, Aomori (Japan). Mutsu Establishment; Kabuto, Shoji [Mutsu Marine Laboratory, Japan Marine Science Foundation, Mutsu, Aomori (Japan); Yamamoto, Tadatoshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2000-02-01

    Tandem-type accelerator mass spectrometer (hereinafter referred to as Tandetron) was installed at the Ominato Facility of Mutsu Establishment, JAERI in April, 1997. The objective of its installation is to investigate the mechanism of the mixing and circulation of seawater in the ocean, by collecting seawater samples around Japan and analyzing the horizontal and vertical distributions of {sup 14}C contained in the samples. The Tandetron consists of two lines to measure isotopic ratios of carbon and those of heavier iodine. The adjustment for the carbon line was finished and the measurements of seawater samples were started. The iodine line, on the other hand, is on the final step of its adjustment and performance tests are being carried out with a TOF (Time of Flight) detector. The iodine line will be used to analyze {sup 129}I released from a spent nuclear fuel reprocessing plant and other nuclear facilities. In this report, we summarize the status of installation of the carbon and iodine lines for the Tandetron. The report describes the situations of their adjustments until now, the outline of the Tandetron, tests of measurement performance, evaluation and inspection of shielding performance, problems and their solutions, and so on. (author)

  4. Preprocessing of Tandem Mass Spectrometric Data Based on Decision Tree Classification

    Institute of Scientific and Technical Information of China (English)

    Jing-Fen Zhang; Si-Min He; Jin-Jin Cai; Xing-Jun Cao; Rui-Xiang Sun; Yan Fu; Rong Zeng; Wen Gao

    2005-01-01

    In this study, we present a preprocessing method for quadrupole time-of-flight(Q-TOF) tandem mass spectra to increase the accuracy of database searching for peptide (protein) identification. Based on the natural isotopic information inherent in tandem mass spectra, we construct a decision tree after feature selection to classify the noise and ion peaks in tandem spectra. Furthermore, we recognize overlapping peaks to find the monoisotopic masses of ions for the following identification process. The experimental results show that this preprocessing method increases the search speed and the reliability of peptide identification.

  5. Simultaneous determination of seven gestagens in kidney fats by Ultra Performance Convergence Chromatography tandem mass spectrometry

    NARCIS (Netherlands)

    Tao, Yanfei; Balzer-Rutgers, Paula; Stolker, A.A.M.; Chen, Dongmei; Yuan, Zonghui

    2015-01-01

    An ultra-performance convergence chromatography (UPC2) system coupled tandem mass spectrometry was successfully utilised to analyse chlormadinone acetate, delmadinone acetate, fluorogestone acetate, medroxyprogesterone acetate, megestrol acetate, melengestrol acetate, chlortestasterone acetate in

  6. Characterization of linear and branched polyacrylates by tandem mass spectrometry.

    Science.gov (United States)

    Chaicharoen, Kittisak; Polce, Michael J; Singh, Anirudha; Pugh, Coleen; Wesdemiotis, Chrys

    2008-10-01

    The unimolecular degradation of alkali-metal cationized polyacrylates with the repeat unit CH(2)CH(COOR) and a variety of ester pendants has been examined by tandem mass spectrometry. The fragmentation patterns resulting from collisionally activated dissociation depend sensitively on the size of the ester alkyl substituent (R). With small alkyl groups, as in poly(methyl acrylate), lithiated or sodiated oligomers (M) decompose via free-radical chemistry, initiated by random homolytic C-C bond cleavages along the polymer chain. The radical ions formed this way dissociate further by backbiting rearrangements and beta scissions to yield a distribution of terminal fragments with one of the original end groups and internal fragments with 2-3 repeat units. If the ester alkyl group bears three or more carbon atoms, cleavages within the ester moieties become the predominant decomposition channel. This distinct reactivity is observed if R = t-butyl, n-butyl, or the mesogenic group (CH(2))(11)-O-C(6)H(4)-C(6)H(4)-CN. The [M+alkali metal](+) ions of the latter polyacrylates dissociate largely by charge-remote 1,5-H rearrangements that convert COOR to COOH groups by expulsion of 1-alkenes. The acid groups may displace an alcohol unit from a neighboring ester pendant to form a cyclic anhydride, unless hindered by steric effects. Using atom transfer radical polymerization, hyperbranched polyacrylates were prepared carrying ester groups both within and between the branches. Unique alkenes and alcohols are cleaved from ester groups at the branching points, enabling determination of the branching architecture. PMID:18373231

  7. 10 K Ring Electrode Trap—Tandem Mass Spectrometer for Infrared Spectroscopy of Mass Selected Ions

    Science.gov (United States)

    Goebbert, Daniel J.; Meijer, Gerard; Asmis, Knut R.

    2009-03-01

    A novel instrumental setup for measuring infrared photodissociation spectra of buffer gas cooled, mass-selected ions is described and tested. It combines a cryogenically cooled, linear radio frequency ion trap with a tandem mass spectrometer, optimally coupling continuous ion sources to pulsed laser experiments. The use of six independently adjustable DC potentials superimposed over the trapping radio frequency field provides control over the ion distribution within, as well as the kinetic energy distribution of the ions extracted from the ion trap. The scheme allows focusing the ions in space and time, such that they can be optimally irradiated by a pulsed, widely tunable infrared photodissociation laser. Ion intensities are monitored with a time-of-flight mass spectrometer mounted orthogonally to the ion trap axis.

  8. 10 K Ring Electrode Trap - Tandem Mass Spectrometer for Infrared Spectroscopy of Mass Selected Ions

    International Nuclear Information System (INIS)

    A novel instrumental setup for measuring infrared photodissociation spectra of buffer gas cooled, mass-selected ions is described and tested. It combines a cryogenically cooled, linear radio frequency ion trap with a tandem mass spectrometer, optimally coupling continuous ion sources to pulsed laser experiments. The use of six independently adjustable DC potentials superimposed over the trapping radio frequency field provides control over the ion distribution within, as well as the kinetic energy distribution of the ions extracted from the ion trap. The scheme allows focusing the ions in space and time, such that they can be optimally irradiated by a pulsed, widely tunable infrared photodissociation laser. Ion intensities are monitored with a time-of-flight mass spectrometer mounted orthogonally to the ion trap axis.

  9. Liquid Chromatography-Electrospray Quadrupole Linear Ion Trap Mass Spectrometric Method for Quantitation of Domperidone in Chinese Healthy Volunteers

    Institute of Scientific and Technical Information of China (English)

    WU Yi; CHU Yang; ZHANG Yun-hui; WU Dan; GU Jing-kai

    2007-01-01

    A rapid, sensitive, and accurate method based on LC/MS/MS was developed and validated for the determination of domperidone in human plasma. Domperidone and internal standard, tramadol, were extracted from plasma with diethyl ether-dichloromethane(60: 40, volume ratio) and separated by reversed-phase HPLC with methanol-water-ammonia solution(80: 20: 0.2, volume ratio) as the mobile phase. Detection was carried out via multiple-reaction monitoring(MRM) on a Q-trapTM LC/MS/MS system(Q-trapTM). The assay result was linear over a concentration range of 0.1-30 ng/mL with a limit of quantitation (LOQ) of 0.1 ng/mL. The inter- and intra-day precision levels were within 7.52% and 12. 9%, respectively, whereas the accuracy was within a range of 87. 3%-114%. This method has been successfully applied to evaluate the pharmacokinetics of domperidone in Chinese healthy volunteers given an oral dose of 10 mg.

  10. Development of a high performance liquid chromatography tandem mass spectrometry based analysis for the simultaneous quantification of various Alternaria toxins in wine, vegetable juices and fruit juices.

    Science.gov (United States)

    Zwickel, Theresa; Klaffke, Horst; Richards, Keith; Rychlik, Michael

    2016-07-15

    An analytical method based on high performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS) detection for the simultaneous quantification of 12 Alternaria toxins in wine, vegetable juices and fruit juices was developed. Excellent chromatographic performance was demonstrated for tenuazonic acid (TeA) in a multi-analyte method. This comprehensive study is also the first to report the determination of TeA, alternariol (AOH), alternariol monomethyl ether (AME), tentoxin (TEN) and altenuene (ALT), altertoxin I (ATX-I), altertoxin II (ATX-II), altenuisol (ATL), iso-altenuene (isoALT), altenuic acid III (AA-III) and the AAL toxins TB1 und TB2 in samples from the German market. Several types of HPLC columns were tested for the liquid chromatographic separation of the toxins of interest that widely differ in their polarities. The focus was on gaining suitable retention while avoiding derivatization steps especially for TeA and AA-III. Three atmospheric pressure ionization techniques used with liquid chromatography (electrospray, chemical and photo ionization) were tested to obtain the best selectivity and sensitivity. Samples were diluted with sodium hydrogen carbonate buffer and extracted on a diatomaceous earth solid phase extraction cartridge. Method validation was carried out by using tomato juice, citrus juice and white wine as blank matrices. Limits of detection ranged from 0.10 to 0.59μgL(-1) and limits of quantification ranged from 0.4-3.1μgL(-1) depending on the toxin and matrix. Recoveries were around 100±9% for all toxins except stemphyltoxin III (STTX-III) and altenusin (ALS) due to instability during sample clean up. Matrix-induced effects leading to ion suppression especially for ATX-I, ATX-II and AA-III were investigated. Relative standard deviations of repeatability (RSDr) and intermediate reproducibility (RSDR) were ≤9.3 and ≤17.1, respectively, for the toxins in different matrices at levels of 5 and 30μgL(-1). Finally, 103

  11. Differentiating samples and experimental protocols by direct comparison of tandem mass spectra

    DEFF Research Database (Denmark)

    van der Plas-Duivesteijn, Suzanne J.; Wulff, Tune; Klychnikov, Oleg;

    2016-01-01

    Peptide tandem mass spectra can be analyzed by a number of means. They can be compared against predicted spectra of peptides derived from genome sequences, compared against previously acquired and identified spectra, or - sometimes - sequenced de novo. We recently introduced another method which...... compares spectra between liquid chromatography/tandem mass spectrometry (LC/MS/MS) datasets to determine the shared spectral content, and demonstrated how this can be applied in a molecular phylogenetic study using sera from human and non-human primates. We will here explore if such a method have other...... aiming for quality control of two traceable protein reference standards (troponin) used in clinical chemistry assays, by analysing the effect of storage conditions. The results illustrate a broad applicability of the metric based on shared tandem mass spectra between LC/MS/MS datasets for analysing...

  12. Plasma Desorption Mass Spectrometry using TANDEM accelerator in National Industrial Research Inst. of Nagoya

    Energy Technology Data Exchange (ETDEWEB)

    Mizota, Takeshi; Nakao, Setsuo; Niwa, Hiroaki; Saito, Kazuo [Particle Beam Sceince Laboratory, Multi-Function Material Science Department, National Industrial Research Inst. of Nagoya, Nagoya (Japan)

    2001-02-01

    Plasma Desorption Mass Spectrometry (PDMS) analysis was studied using TANDEM accelerator. The heavy ions of MeV range emit the secondary ions of atoms, molecules, polymers and clusters from the irradiated samples without destruction. The analysis system of PDMS designed and set-up using a mass spectrometer of Time of Flight and the TANDEM accelerator. The system performance was tested for C-60 fullerene on the surface of the samples using 11.2 MeV {sup 28}Si beams produced by the TANDEM accelerator of 1.7MV. The result shows that the hydrogen and hydrocarbons can be analyzed in the range of 1amu unit. The resolution (M/{delta}M) of the Mass Spectrometry system is confirmed to be about 1000 from the separation of the 720 and 721amu peaks, which is attributed to the C-60 fullerene including {sup 13}C atoms. (H. Katsuta)

  13. 液相色谱-串联质谱法检测贝类产品中腹泻性贝类毒素%Determination of Diarrhetic Shellfish Poisoning in Shellfishes by Liquid Chromatography with Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    母清林; 方杰; 万汉兴; 王晓华; 曹柳燕; 张庆红

    2011-01-01

    建立了贝类组织中2种腹泻性贝毒(Diamletic shellfish Poisobing,DSP)聚醚类毒素-大田软海绵酸(Okadaic acid,OA)和鳍藻毒素(Dinophysistoxin-1,DTX-1)的高效液相色谱-串联质谱分析方法.贝类样品经80%甲醇溶液提取,经正己烷脱脂和HLB固相萃取柱净化,采用Pursuit C18(150 mm×3.0 mm,3 μm,varian公司)色谱柱分离,以80%(V/V)甲醇水溶液为流动相等度洗脱,负离子扫描,在多反应监测(MRM)模式下进行定性与定量分析.在4~200 μg/L范围内线性关系良好,OA和DTX-1的最低定量限均为2 μg/kg.添加水平在2,25和50 μg/kg时的平均回收率大于80%,相对标准偏差小于11%(n=6).%A liquid chromatography-electrospray ionization triple-quadruple tandem.mass spectrometric method has been established for the determination of two kinds of diarrhetic shellfish poisoning including okadaic acid (QA) and dinophysistoxin-1 (DTX-1). After being extracted using methanol and water(80∶20, V/V ), the solution was extracted with n-hexane to remove lipid components and then cleaned-up by solid phase extraction (SPE) on an Oasis HLB cartridge. The analytes were eluted with methanol-water (80:20, V/V) on a Pursuit C18 column (150 mm×3.0 mm, 3 μm). The quantitative and confirmatory determination of OA and DTX-1 was performed by multiple reactions monitoring (MRM) mode. OA and DTX-1 were determined in the negative ion mode. The calibration curve was linear in the range of 4- 200 μg/L. The quantification limits of OA and DTX-1 were 2 μg/kg. The mean recoveries at spiked concentration of 2-100 μg/kg were more than 80% and the relative standard deviations were less than 11% (n=6).

  14. A multi-class bioanalytical methodology for the determination of bisphenol A diglycidyl ethers, p-hydroxybenzoic acid esters, benzophenone-type ultraviolet filters, triclosan, and triclocarban in human urine by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Asimakopoulos, Alexandros G; Wang, Lei; Thomaidis, Nikolaos S; Kannan, Kurunthachalam

    2014-01-10

    A liquid-liquid extraction (LLE; ethyl acetate) protocol, followed by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) methodology, was developed for the determination of 19 compounds, including bisphenol A diglycidyl ethers (BADGEs; industrial ethers), benzophenone-type UV filters (BP-UV filters; precursors and metabolites), p-hydroxybenzoic acid esters (parabens; preservatives), triclosan (TCS) and triclocarban (TCC) in human urine. Urine specimens were enzymatically deconjugated with β-glucuronidase (from Helix pomatia) and extracted by a LLE procedure for the measurement of total concentrations (i.e., free+conjugated forms) of target analytes. Absolute recoveries of BADGEs, BP-UV filters, parabens, TCS and TCC ranged 25-135%, 84-125%, 52-126%, 75-118% and 90-124%, respectively. Method precision (absolute values; N=5 replicate analyses at the fortification level of 10 ng, k=5 days) ranged from 5.8 (ethyl paraben) to 24.0% (TCS). The limits of quantification (LOQs) varied depending on the target compound and generally ranged from 0.2 to 2.0 ng/mL. The matrix effects ranged from +11 (2,3,4-trihydroxybenzophenone) to -86% (2,4-dihydroxybenzophenone). A total of 30 urine specimens collected from Athens, Greece, were analyzed for the 19 target compounds to demonstrate the applicability of the developed method. The concentrations of target chemicals in urine were presented on volume-, specific gravity (SG)-, and creatinine-normalization bases. MeP, EtP, PrP, OH-EtP, BADGE·2H2O, BP-1 and TCS were found frequently in urine at concentrations in the range of 2.7-436 ng/mL, <0.5-25.4 ng/mL, <0.5-575 ng/mL, <2-18.4 ng/mL, <0.5-13.8 ng/mL, <1-14.6 ng/mL and <0.5-95.3 ng/mL, respectively. PMID:24315674

  15. Study of electrospray ionization tandem mass spectrometry of the benzofuranone compounds

    Institute of Scientific and Technical Information of China (English)

    Zhan Qi Niu; Yu Min Sun; Feng Niu; Jian Han; Da Wei Chen

    2008-01-01

    A detailed analysis of benzofuranone compounds under multiple tandem mass spectrometry (ESI-MS(n)) conditions is reported. Element composition data of the fragment ions were obtained with the aid of comparison of the multiple tandem mass spectra of four compounds, and the structures of which are identical except for some substituted groups or epimers or ra-r/ww-isomers. Attempts have been made to provide rational pathways for the formation of the fragment ions from these protonated compounds. And the structure-fragmentation relationships will facilitate the characterization of the structures of other analogs.

  16. High explosives vapor detection by atmospheric sampling glow discharge ionization/tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    McLuckey, S.A.; Goeringer, D.E.; Asano, K.G. [Oak Ridge National Lab., TN (United States). Chemical and Analytical Sciences Div.

    1996-02-01

    The combination of atmospheric sampling glow discharge ionization with tandem mass spectrometry for the detection of traces of high explosives is described. Particular emphasis is placed on use of the quadrupole ion trap as the type of tandem mass spectrometer. Atmospheric sampling glow discharge provides a simple, rugged, and efficient means for anion formation while the quadrupole ion trap provides for efficient tandem mass spectrometry. Mass selective ion accumulation and non-specific ion activation methods can be used to overcome deleterious effects arising from ion/ion interactions. Such interactions constitute the major potential technical barrier to the use of the ion trap for real-time monitoring of targeted compounds in uncontrolled and highly variable matrices. Tailored waveforms can be used to effect both mass selective ion accumulation and ion activation. Concatenated tailored waveforms allow for both functions in a single experiment thereby providing the capability for monitoring several targeted species simultaneously. The combination of atmospheric sampling glow discharge ionization with a state-of-the-art analytical quadrupole ion trap is a highly sensitive and specific detector for traces of high explosives. The combination is also small and inexpensive relative to virtually any other form of tandem mass spectrometry. The science and technology underlying the glow discharge/ion trap combination is sufficiently mature to form the basis for an engineering effort to make the detector portable. 85 refs.

  17. Metabolism of halogenated compounds in the white rot fungus Bjerkandera adusta studied by membrane inlet mass spectrometry and tandem mass spectrometry

    DEFF Research Database (Denmark)

    Beck, Hans Christian; Lauritsen, F.R.; Patrick, J.S.;

    1996-01-01

    Membrane inlet mass spectrometry has been used for the characterization of halogenated organic compounds produced by the fungus Bjerkandera adusta. Using this technique, electron impact-, chemical ionization-, electron capture negative chemical ionization-mass spectra and tandem mass spectra were...

  18. Chemical ionization tandem mass spectrometer for the in situ measurement of methyl hydrogen peroxide

    International Nuclear Information System (INIS)

    A new approach for measuring gas-phase methyl hydrogen peroxide [(MHP) CH3OOH] utilizing chemical ionization mass spectrometry is presented. Tandem mass spectrometry is used to avoid mass interferences that hindered previous attempts to measure atmospheric CH3OOH with CF3O- clustering chemistry. CH3OOH has been successfully measured in situ using this technique during both airborne and ground-based campaigns. The accuracy and precision for the MHP measurement are a function of water vapor mixing ratio. Typical precision at 500 pptv MHP and 100 ppmv H2O is ±80 pptv (2 sigma) for a 1 s integration period. The accuracy at 100 ppmv H2O is estimated to be better than ±40%. Chemical ionization tandem mass spectrometry shows considerable promise for the determination of in situ atmospheric trace gas mixing ratios where isobaric compounds or mass interferences impede accurate measurements.

  19. Fully automated screening of veterinary drugs in milk by turbulent flow chromatography and tandem mass spectrometry

    NARCIS (Netherlands)

    Stolker, A.A.M.; Peters, R.J.B.; Zuiderent, R.; DiBussolo, J.M.; Martins, C.P.B.

    2010-01-01

    There is an increasing interest in screening methods for quick and sensitive analysis of various classes of veterinary drugs with limited sample pre-treatment. Turbulent flow chromatography in combination with tandem mass spectrometry has been applied for the first time as an efficient screening met

  20. Multiresidue analysis of pesticides in straw roughage by liquid chromatography - tandem mass spectrometry

    Science.gov (United States)

    A multiresidue analytical method using a modification of the “quick, easy, cheap, effective, rugged, and safe” (QuEChERS) sample preparation approach combined with liquid chromatography–tandem mass spectrometry (LC-MS/MS) analysis was established and validated for the rapid determination of 69 pesti...

  1. Combined Dynamic Arrays for Storing and Searching Semi-Ordered Tandem Mass Spectrometry Data

    Science.gov (United States)

    When performing bioinformatics analysis on tandem mass spectrometry data, there is a computational need to efficiently store and sort these semi-ordered data sets. To solve this problem, a new data structure based on dynamic arrays was designed and implemented in an algorithm that parses semi-order...

  2. A novel high-capacity ion trap-quadrupole tandem mass spectrometer

    Science.gov (United States)

    Krutchinsky, Andrew N.; Cohen, Herbert; Chait, Brian T.

    2007-12-01

    We describe a prototype tandem mass spectrometer that is designed to increase the efficiency of linked-scan analyses by >100-fold over conventional linked-scan instruments. The key element of the mass spectrometer is a novel high ion capacity ion trap, combined in tandem configuration with a quadrupole collision cell and a quadrupole mass analyzer (i.e. a TrapqQ configuration). This ion trap can store >106 ions without significant degradation of its performance. The current mass resolution of the trap is 100-450 full width at half maximum for ions in the range 800-4000 m/z, yielding a 10-20 m/z selection window for ions ejected at any given time into the collision cell. The sensitivity of the mass spectrometer for detecting peptides is in the low femtomole range. We can envisage relatively straightforward modifications to the instrument that should improve both its resolution and sensitivity. We tested the tandem mass spectrometer for collecting precursor ion spectra of all the ions stored in the trap and demonstrated that we can selectively detect a phosphopeptide in a mixture of non-phosphorylated peptides. Based on this prototype instrument, we plan to construct a fully functional model of the mass spectrometer for detecting modification sites on proteins and profiling their abundances with high speed and sensitivity.

  3. BF3-catalyzed methanolysis combined with FAB tandem mass spectrometry as a new tool for sequencing of cyclosporins

    Czech Academy of Sciences Publication Activity Database

    Havlíček, Vladimír; Jegorov, A.; Sedmera, Petr; Ryska, M.

    Barcelona : Grupo de Cromatografia y Tecnicas Afines, 1995, s. 7. [International Symposium on Applied Mass Spectrometry in the Health Sciences - European Tandem Mass Spectrometry Conference /3./. Barcelona (ES), 09.07.1995-13.07.1995

  4. Quantitative analysis of phytosterols in edible oils using APCI liquid chromatography-tandem mass spectrometry

    OpenAIRE

    Mo, Shunyan; Dong, Linlin; Hurst, W Jeffrey; van Breemen, Richard B

    2013-01-01

    Previous methods for the quantitative analysis of phytosterols have usually used GC-MS and require elaborate sample preparation including chemical derivatization. Other common methods such as HPLC with absorbance detection do not provide information regarding the identity of the analytes. To address the need for an assay that utilizes mass selectivity while avoiding derivatization, a quantitative method based on LC-tandem mass spectrometry (LC-MS-MS) was developed and validated for the measur...

  5. Analyses of Phytohormones in Coconut (Cocos Nucifera L.) Water Using Capillary Electrophoresis-Tandem Mass Spectrometry

    OpenAIRE

    Swee Ngin Tan; Jean Wan Hong Yong; Liya Ge

    2014-01-01

    Capillary electrophoresis (CE) coupled with mass spectrometry (MS) or tandem mass spectrometry (MS/MS) is reported as an alternative and potentially useful method for the simultaneous analysis of various classes of phytohormones with diversified structures, including indole-3-acetic acid (IAA), indole-3-butyric acid (IBA), abscisic acid (ABA), gibberellic acid (GA), zeatin (Z), N6-benzyladenine (BA), α-naphthaleneacetic acid (NAA) and 2,4-dichlorophenoxyacetic acid (2,4-D). The key to the CE-...

  6. Determination of Bedaquiline in Human Serum Using Liquid Chromatography-Tandem Mass Spectrometry

    OpenAIRE

    Alffenaar, Jan-Willem C; Bolhuis, Mathieu; van Hateren, Kai; Sturkenboom, Marieke; Akkerman, Onno; de Lange, Wiel; Greijdanus, Ben; van der Werf, Tjip; Touw, Daan

    2015-01-01

    Bedaquiline, a diarylquinoline for the treatment of multidrug-resistant tuberculosis (TB), relies on exposure-dependent killing. As data on drug exposure in specific populations are scarce, pharmacokinetic studies may be of interest. No simple and robust validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been reported to date. Therefore, a new method using a quadrupole mass spectrometer was developed for analysis of bedaquiline and N-monodesmethyl bedaquiline (M2) ...

  7. Selected Tandem Mass pectrometry Ion Monitoring for the fast identification of seafood

    OpenAIRE

    Ortea, Ignacio; Cañas, Benito; Gallardo, José Manuel

    2011-01-01

    Selected tandem mass spectrometry (MS/MS) ion monitoring (SMIM) is the most suitable scanning mode to detect known peptides in complex samples when an ion-trap mass spectrometer is the instrument used for the analysis. In this mode, the MS detector is programmed to perform continuous MS/MS scans on one or more selected precursors, either during a selected time interval, or along the whole chromatographic run. MS/MS spectra are recorded, so virtual multiple reaction monitoring chro...

  8. A collinear tandem time-of-flight mass spectrometer for infrared photodissociation spectroscopy of mass-selected ions

    Institute of Scientific and Technical Information of China (English)

    WANG GuanJun; CHI ChaoXian; XING XiaoPeng; DING ChuanFan; ZHOU MingFei

    2014-01-01

    An apparatus based on collinear tandem time-of-flight mass spectrometer has been designed for the measurement of infrared photodissociation spectroscopy of mass-selected ions in the gas phase.The ions from a pulsed laser vaporization supersonic ion source are skimmed and mass separated by a Wiley-McLaren time-of-flight mass spectrometer.The ion of interest is mass selected,decelerated and dissociated by a tunable IR laser.The fragment and parent ions are reaccelerated and mass analyzed by the second time-of-flight mass spectrometer.A simple new assembly integrated with mass gate,deceleration and reacceleration ion optics was designed,which allows us to measure the infrared spectra of mass selected ions with high sensitivity and easy timing synchronization.

  9. Atmospheric sampling glow discharge ionizataion and triple quadrupole tandem mass spectrometry for explosives vapor detection

    Energy Technology Data Exchange (ETDEWEB)

    McLuckey, S.A.; Goeringer, D.E.; Asano, K.G.; Hart, K.J.; Glish, G.L.; Grant, B.C.; Chambers, D.M.

    1993-08-01

    The detection and identification of trace vapors of hidden high explosives is an excellent example of a targeted analysis problem. It is desirable to push to ever lower levels the quantity or concentration of explosives material that provides an analytical signal, while at the same time discriminating against all other uninteresting material. The detection system must therefore combine high sensitivity with high specificity. This report describes the philosophy behind the use of atmospheric sampling glow discharge ionization, which is a sensitive, rugged, and convenient means for forming anions from explosives molecules, with tandem mass spectrometry, which provides unparalleled specificity in the identification of explosives-related ions. Forms of tandem mass spectrometry are compared and contrasted to provide a summary of the characteristics to be expected from an explosives detector employing mass spectrometry/mass spectrometry. The instrument developed for the FAA, an atmospheric sampling glow discharge/triple quadrupole mass spectrometer, is described in detail with particular emphasis on the ion source/spectrometer interface and on the capabilities of the spectrometer. Performance characteristics of the system are also described as they pertain to explosives of interest including a description of an automated procedure for the detection and identification of specific explosives. A comparison of various tandem mass spectrometers mated with atmospheric sampling glow discharge is then described and preliminary studies with a vapor preconcentration system provided by the FAA will be described.

  10. High Energy Collisions on Tandem Time-of-Flight Mass Spectrometers

    Science.gov (United States)

    Cotter, Robert J.

    2013-05-01

    Long before the introduction of matrix-assisted laser desorption/ionization (MALDI), electrospray ionization (ESI), Orbitraps, and any of the other tools that are now used ubiquitously for proteomics and metabolomics, the highest performance mass spectrometers were sector instruments, providing high resolution mass measurements by combining an electrostatic energy analyzer (E) with a high field magnet (B). In its heyday, the four sector mass spectrometer (or EBEB) was the crown jewel, providing the highest performance tandem mass spectrometry using single, high energy collisions to induce fragmentation. During a time in which quadrupole and tandem triple quadrupole instruments were also enjoying increased usage and popularity, there were, nonetheless, some clear advantages for sectors over their low collision energy counterparts. Time-of-flight (TOF) mass spectrometers are high voltage, high vacuum instruments that have much in common with sectors and have inspired the development of tandem instruments exploiting single high energy collisions. In this retrospective, we recount our own journey to produce high performance TOFs and tandem TOFs, describing the basic theory, problems, and the advantages for such instruments. An experiment testing impulse collision theory (ICT) underscores the similarities with sector mass spectrometers where this concept was first developed. Applications provide examples of more extensive fragmentation, side chain cleavages, and charge-remote fragmentation, also characteristic of high energy sector mass spectrometers. Moreover, the so-called curved-field reflectron has enabled the design of instruments that are simpler, collect and focus all of the ions, and may provide the future technology for the clinic, for tissue imaging, and the characterization of microorganisms.

  11. The study of radiation induced DNA-protein crosslinks by electrospray ionization mass spectrometry

    International Nuclear Information System (INIS)

    The authors have used peptide-thymine and histone-thymine solutions to model protein-DNA cross-linking chemistry induced in intact chromatin by low dosage of g-irradiation. Induced thymine crosslinking to model peptide systems has been evaluated by on-line liquid chromatography-electrospray ionization mass spectrometry (ESI-MS) and tandem mass spectrometry (MS-MS) with sensitivity comparable or superior to conventional GC-MS determinations. Radiation damage at doses as low as 0.1 Gy can be detected by this method. Additionally, thymine modified H2B can also be examined by ESI-MS and tandem-MS of the intact protein and proteinase digests. Limited information on the sites of thymine crosslinking can be obtained by tandem mass spectrometry on the intact multiply charged molecular species. More detailed information on the sites of thymine-protein crosslinking is obtained by on-line LC-ESI-MS of selective proteolysis products of the modified histones. Further MS-MS experiments on the selective proteolysis products will reveal specific modified amino acids and their sequence location. These methods reveal the nature, extent and site of radiation induced modification of the oligopeptides. Studies are being extended to the examination of the radiation induced covalent interactions between histones and oligonucleotides in higher states of organization. The eventual object is to study DNA-protein crosslinking interactions in model and native genomic nucleosome systems

  12. A computational framework for heparan sulfate sequencing using high-resolution tandem mass spectra

    DEFF Research Database (Denmark)

    Hu, Han; Huang, Yu; Mao, Yang;

    2014-01-01

    activities. Its biological activities depend on the fine structures of its protein-binding domains, the determination of which remains a daunting task. Methods have advanced to the point that mass spectra with information-rich product ions may be produced on purified HS saccharides. However, the...... interpretation of these complex product ion patterns has emerged as the bottleneck to the dissemination of these HS sequencing methods. To solve this problem, we designed HS-SEQ, the first comprehensive algorithm for HS de novo sequencing using high-resolution tandem mass spectra. We tested HS-SEQ using negative...... electron transfer dissociation (NETD) tandem mass spectra generated from a set of pure synthetic saccharide standards with diverse sulfation patterns. The results showed that HS-SEQ rapidly and accurately determined the correct HS structures from large candidate pools....

  13. Quantitation of protein post-translational modifications using isobaric tandem mass tags.

    Science.gov (United States)

    Liang, Hui-Chung; Lahert, Emma; Pike, Ian; Ward, Malcolm

    2015-01-01

    Post-translational modifications (PTMs) of proteins are known to modulate many cellular processes and their qualitative and quantitative evaluation is fundamental for understanding the mechanisms of biological events. Over the past decade, improvements in sample preparation techniques and enrichment strategies, the development of quantitative labeling strategies, the launch of a new generation of mass spectrometers and the creation of bioinformatics tools for the interrogation of ever larger datasets has established MS-based quantitative proteomics as a powerful workflow for global proteomics, PTM analysis and the elucidation of key biological mechanisms. With the advantage of their multiplexing capacity and the flexibility of an ever-growing family of different peptide-reactive groups, isobaric tandem mass tags facilitate quantitative proteomics and PTM experiments and enable higher sample throughput. In this review, we focus on the technical concept and utility of the isobaric tandem mass tag labeling approach to PTM analysis, including phosphorylation, glycosylation and S-nitrosylation. PMID:25697195

  14. Peptide de novo sequencing of mixture tandem mass spectra

    DEFF Research Database (Denmark)

    Gorshkov, Vladimir; Hotta, Stéphanie Yuki Kolbeck; Braga, Thiago Verano;

    2016-01-01

    complementary b-, y-ions to each precursor peptide mass, which allowed the creation of virtual spectra containing sequence specific fragment ions of each co-isolated peptide. Deconvolution processing resulted in equally efficient identification rates but increased the absolute number of correctly sequenced...... peptides. The improvement was in the range of 20–35% additional peptide identifications for a HeLa lysate sample. Some correct sequences were identified only using unprocessed spectra; however, the number of these was lower than those where improvement was obtained by mass spectral deconvolution. Tight......The impact of mixture spectra deconvolution on the performance of four popular de novo sequencing programs was tested using artificially constructed mixture spectra as well as experimental proteomics data. Mixture fragmentation spectra are recognized as a limitation in proteomics because they...

  15. Evaluation of Physiological Amino Acids Profiling by Tandem Mass Spectrometry

    OpenAIRE

    Filee, Romain; Schoos, Roland; Boemer, François

    2013-01-01

    Background: Nowadays, the most conventional method to quantify physiological amino acids consists in ion exchange chromatography (IEC) followed by post-column ninhydrin derivatization and UV detection at two wavelengths. Unfortunately, the technique presents some drawbacks such as long run time, large sample volume, and specific costs associated to the maintenance of a dedicated instrument. Therefore, we aimed to switch towards a mass spectrometry approach.

  16. Analysis of Norditerpenoid Alkaloids Extracted from Aconitum sinomantanum Nakai by Electrospray Ionization Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Electrospray ionization mass spectrometry(ESI-MS) was applied simultaneously in determining norditerpenoid alkaloids from the roots of Aconitum sinomantanum Nakai (RAS) based on molecular mass information. The tandem mass spectra(ESI-MSn) provided the alkaloidal structural information, through which the existence of these alkaloids was further confirmed. Accordingly, six known norditerpenoid alkaloids were simultaneously determined on the basis of their ESI-MSn spectra. Furthermore, based on the diagnostic fragmentation pathways of alkaloidal MSn, a rapid method for direct detection and characterization of alkaloids from an ethanolic extract of RAS was described.

  17. Quantification of salsolinol enantiomers by stable isotope dilution liquid chromatography with tandem mass spectrometric detection

    OpenAIRE

    Cai, Min; Liu, Yi-Ming

    2008-01-01

    Salsolinol, 1-methyl-6,7-dihydroxy-2,3,4,5-tetrahydroisoquinoline (SAL), is a precursor of a Parkinsonian neurotoxin, N-methysalsolinol (N-methyl-SAL). Previous studies have shown that individual enantiomers of N-methyl-SAL possess distinct neurotoxicological properties. In this work, a chiral high-performance liquid chromatography (HPLC) method with electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the quantification of (R/S)-SAL enantiomers. Enantiose...

  18. An improved method for measuring metaldehyde in surface water using liquid chromatography tandem mass spectrometry

    OpenAIRE

    Schumacher, Melanie; Castle, Glenn; Gravell, Anthony; Mills, Graham; Fones, Gary Roland

    2016-01-01

    The molluscicide metaldehyde (2,4,6,8-tetramethyl-1,3,5,7-tetraoxocanemetacetaldehyde) is an emerging pollutant. It is frequently detected in surface waters, often above the European Community Drinking Water Directive limit of 0.1 μg/L for a single pesticide. Gas chromatography mass spectrometry (GC–MS) can be used to determine metaldehyde in environmental waters, but this method requires time consuming extraction techniques prior to instrumental analysis. Use of liquid chromatography-tandem ...

  19. A Review of Tandem Mass Spectrometry Characterization of Adenosine Diphosphate-Ribosylated Peptides

    OpenAIRE

    Hengel, Shawna M.; Goodlett, David R.

    2011-01-01

    The use of tandem mass spectrometry to identify and characterize sites of protein adenosine diphosphate (ADP) ribosylation will be reviewed. Specifically, we will focus on data acquisition schemes and fragmentation techniques that provide peptide sequence and modification site information. Also discussed are uses of synthetic standards to aid characterization, and an enzymatic method that converts ADP-ribosylated peptides into ribosyl mono phosphorylated peptides making identification amenabl...

  20. Direct Quantification of Cannabinoids and Cannabinoid Glucuronides in Whole Blood by Liquid Chromatography Tandem Mass Spectrometry

    OpenAIRE

    Schwope, David M.; Scheidweiler, Karl B.; Huestis, Marilyn A.

    2011-01-01

    The first method for quantifying cannabinoids and cannabinoid glucuronides in whole blood by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and validated. Solid-phase extraction followed protein precipitation with acetonitrile. HPLC separation was achieved in 16 min via gradient elution. Electrospray ionization was utilized for cannabinoid detection; both positive (Δ9-tetrahydrocannabinol [THC], cannabinol [CBN]) and negative (11-hydroxy-THC [11-OH-THC], 11-nor-9-carb...

  1. Detection of 10 sweeteners in various foods by liquid chromatography/tandem mass spectrometry

    OpenAIRE

    Chui-Shiang Chang; Tai Sheng Yeh

    2014-01-01

    The analytical method for sweeteners in various food matrixes is very important for food quality control and regulation enforcement. A simple and rapid method for the simultaneous determination of 10 sweeteners [acesulfame potassium (ACS-K), aspartame (ASP), cyclamate (CYC), dulcin (DUL), glycyrrhizic acid (GA), neotame (NEO), neohesperidin dihydrochalcone (NHDC), saccharin (SAC), sucralose (SCL), and stevioside (STV)] in various foods by liquid chromatography/tandem mass chromatography (LC–M...

  2. Ion Mobility and Tandem Mass Spectrometry of Phosphatidylglycerol and Bis(monoacylglycerol)phosphate (BMP)

    OpenAIRE

    Hankin, Joseph A.; Murphy, Robert C.; Barkley, Robert M.; Gijón, Miguel A.

    2015-01-01

    The tandem mass spectrometry, ion mobility, and normal phase HPLC of isomeric phosphatidylglycerol (PG) and bis(monoacylglycerol)phosphate (BMP) have been investigated in this study with the objective of differentiating these unique classes of lipids. Measurement of ion mobility using the traveling wave method for negative molecular and product ions from isomeric PG and BMP yielded identical results, but different ion mobilities were observed for positive product ions arising from collision-i...

  3. A review of clinical diagnostic applications of liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Shushan, Bori

    2010-01-01

    Liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS) technology is emerging as a complementary method to traditional methodology used for clinical applications. Enhanced specificity and high-throughput capabilities are providing significant benefits to clinical diagnostic laboratories conducting routine analyses. This technology is expected to expand rapidly as scientists focus on more complicated challenges that can be solved efficiently by adding LC/MS/MS to their arsenal of techniques. PMID:20949635

  4. Fast multi-blind modification search through tandem mass spectrometry.

    Science.gov (United States)

    Na, Seungjin; Bandeira, Nuno; Paek, Eunok

    2012-04-01

    With great biological interest in post-translational modifications (PTMs), various approaches have been introduced to identify PTMs using MS/MS. Recent developments for PTM identification have focused on an unrestrictive approach that searches MS/MS spectra for all known and possibly even unknown types of PTMs at once. However, the resulting expanded search space requires much longer search time and also increases the number of false positives (incorrect identifications) and false negatives (missed true identifications), thus creating a bottleneck in high throughput analysis. Here we introduce MODa, a novel "multi-blind" spectral alignment algorithm that allows for fast unrestrictive PTM searches with no limitation on the number of modifications per peptide while featuring over an order of magnitude speedup in relation to existing approaches. We demonstrate the sensitivity of MODa on human shotgun proteomics data where it reveals multiple mutations, a wide range of modifications (including glycosylation), and evidence for several putative novel modifications. Based on the reported findings, we argue that the efficiency and sensitivity of MODa make it the first unrestrictive search tool with the potential to fully replace conventional restrictive identification of proteomics mass spectrometry data. PMID:22186716

  5. Ligand binding mode to duplex and triplex DNA assessed by combining electrospray tandem mass spectrometry and molecular modeling

    OpenAIRE

    Rosu, Frédéric; Nguyen, Chi-Hung; De Pauw, Edwin; Gabelica, Valérie

    2007-01-01

    In this paper, we report the analysis of seven benzopyridoindole and benzopyridoquinoxaline drugs binding to different duplex DNA and triple helical DNA, using an approach combining electrospray ionization mass spectrometry (ESI-MS), tandem mass spectrometry (MS/MS), and molecular modeling. The ligands were ranked according to the collision energy (CE(50)) necessary to dissociate 50% of the complex with the duplex or the triplex in tandem MS. To determine the probable ligand binding site and ...

  6. Characteristic Fragmentation Behavior of Steroidal Phosphoramidate Conjugates in Electrospray Ionization Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    JI, San-Hao; JU, Yong; XIAO, Qiang; ZHAO, Yu-Fen

    2006-01-01

    Novel steroidal phosphoramidate conjugates of 3'-azido-2',3'-dideoxythymidine (AZT) and amino acid esters were synthesized and determined by positive and negative ion electrospray ionization mass spectrometry. The MS fragmentation behaviors of the steroidal phosphoramidate conjugates have been investigated in conjunction with tandem mass spectrometry of ESI-MS/MS. There were three characteristic fragment ions in the positive ion ESI mass spectra, which were the Na adduct ions with loss of steroidal moiety, amino acid ester moiety from pseudo molecular ion (M+Na)+, and the phosphoamino acid methyl ester Na adduct ion by a-cleavage of the phosphoramidate respectively. The main fragment ions in negative ion ESI mass spectra were the ion (M-HN3)-, the ion (M - AZT - H)- , and the ion (M-steroidal moiety-H)- besides the pseudo molecular ion (M-H)-. The fragmentation patterns did not depend on the attached amino acid ester moiety.

  7. Phosphopeptide detection and sequencing by matrix-assisted laser desorption/ionization quadrupole time-of-flight tandem mass spectrometry

    DEFF Research Database (Denmark)

    Bennett, Keiryn L; Stensballe, Allan; Podtelejnikov, Alexandre V;

    2002-01-01

    localization of one, three or four phosphorylated amino acid residues in phosphopeptides up to 3.1 kDa. Tandem mass spectra of two different phosphotyrosine peptides permitted amino acid sequence determination and localization of one and three phosphorylation sites, respectively. The phosphotyrosine immonium...... ion at m/z 216.04 was observed in these MALDI low-energy CID tandem mass spectra. Elimination of phosphate groups was evident from the triphosphorylated peptide but not from the monophosphorylated species. The main fragmentation pathway for the synthetic phosphothreonine-containing peptide and for......A prototype matrix-assisted laser desorption/ionization quadrupole time-of-flight (MALDI-TOF) tandem mass spectrometer was used to sequence a series of phosphotyrosine-, phosphothreonine- and phosphoserine-containing peptides. The high mass resolution and mass accuracy of the instrument allowed the...

  8. Expedient preparative isolation and tandem mass spectrometric characterization of C-seco triterpenoids from Neem oil.

    Science.gov (United States)

    Haldar, Saikat; Mulani, Fayaj A; Aarthy, Thiagarayaselvam; Dandekar, Devdutta S; Thulasiram, Hirekodathakallu V

    2014-10-31

    C-seco triterpenoids are widely bioactive class of natural products with high structural complexity and diversity. The preparative isolation of these molecules with high purity is greatly desirable, although restricted due to the complexity of natural extracts. In this article we have demonstrated a Medium Pressure Liquid Chromatography (MPLC) based protocol for the isolation of eight major C-seco triterpenoids of salannin skeleton from Neem (Azadirachta indica) oil. Successive application of normal phase pre-packed silica-gel columns for the fractionation followed by reverse phase in automated MPLC system expedited the process and furnished highly pure metabolites. Furthermore, eight isolated triterpenoids along with five semi-synthesized derivatives were characterized using ultra performance liquid chromatography-electrospray ionization-quadrupole/orbitrap-MS/MS spectrometry as a rapid and sensitive identification technique. The structure-fragment relationships were established on the basis of plausible mechanistic pathway for the generation of daughter ions. The MS/MS spectral information of the triterpenoids was further utilized for the identification of studied molecules in the complex extract of stem and bark tissues from Neem. PMID:25267707

  9. Gallium metal affinity capture tandem mass spectrometry for the selective detection of phosphopeptides in complex mixtures

    OpenAIRE

    Blacken, Grady R.; Sadílek, Martin; Tureček, František

    2008-01-01

    Metal affinity capture tandem mass spectrometry (MAC-MSMS) is evaluated in a comparative study of a lysine-derived nitrilotriacetic acid (Nα, Nα-bis-(carboxymethyl)lysine, LysNTA) and an aspartic-acid-related iminodiacetic acid (N-(4-aminobutyl)aspartic acid, AspIDA) as selective phosphopeptide detection reagents. Both LysNTA and AspIDA spontaneously form ternary complexes with GaIII and phosphorylated amino acids and phosphopeptides upon mixing in solution. Collision-induced dissociation of ...

  10. A new tandem mass spectrometer for photofragment spectroscopy of cold, gas-phase molecular ions

    International Nuclear Information System (INIS)

    We present here the design of a new tandem mass spectrometer that combines an electrospray ion source with a cryogenically cooled ion trap for spectroscopic studies of cold, gas-phase ions. The ability to generate large ions in the gas phase without fragmentation, cool them to ∼10 K in an ion trap, and perform photofragment spectroscopy opens up new possibilities for spectroscopic characterization of large biomolecular ions. The incorporation of an ion funnel, together with a number of small enhancements, significantly improves the sensitivity, signal stability, and ease of use compared with the previous instrument built in our laboratory.

  11. Authentication of Fish Products by Large-Scale Comparison of Tandem Mass Spectra

    DEFF Research Database (Denmark)

    Wulff, Tune; Nielsen, Michael Engelbrecht; Deelder, André M.;

    2013-01-01

    workflow including protein extraction, digestion, and data analysis. First, a set of reference spectral libraries was generated using unprocessed muscle tissue from 22 different fish species. Query tandem mass spectrometry data sets from “unknown” fresh muscle tissue samples were then searched against...... the reference libraries. The number of matching spectra could unambiguously identify the origin of all fresh samples. A number of processed samples were also analyzed to further test the robustness and applicability of the method. The results clearly show that the method is also able to correctly identify...

  12. Investigation of the neuroleptic drug haloperidol and its metabolites using tandem mass spectrometry

    Science.gov (United States)

    Fang, Jian; Gorrod, John W.; Kajbaf, Mahmud; Lamb, John H.; Naylor, Stephen

    1992-12-01

    The in vitro metabolism of haloperidol, a clinically utilized neuroleptic drug, was investigated using guinea pig derived hepatic microsomal incubates. By employing a combination of reversed phase HPLC and tandem mass spectrometry, it was revealed that haloperidol was metabolized to at least eight different compounds, including the proposed dopaminergic toxin 4-(4-chlorophenyl)-1-[4-(4-fluorophenyl)-4- oxobutyl]-pyridinium species and an intermediate metabolite 4-(4-chlorophenyl)-1-[4-(4-fluorophenyl)-4- oxobutyl]- 1,2,3,6-tetrahydropyridine.

  13. Gas Chromatography/Atmospheric Pressure Chemical Ionization Tandem Mass Spectrometry for Fingerprinting the Macondo Oil Spill.

    Science.gov (United States)

    Lobodin, Vladislav V; Maksimova, Ekaterina V; Rodgers, Ryan P

    2016-07-01

    We report the first application of a new mass spectrometry technique (gas chromatography combined to atmospheric pressure chemical ionization tandem mass spectrometry, GC/APCI-MS/MS) for fingerprinting a crude oil and environmental samples from the largest accidental marine oil spill in history (the Macondo oil spill, the Gulf of Mexico, 2010). The fingerprinting of the oil spill is based on a trace analysis of petroleum biomarkers (steranes, diasteranes, and pentacyclic triterpanes) naturally occurring in crude oil. GC/APCI enables soft ionization of petroleum compounds that form abundant molecular ions without (or little) fragmentation. The ability to operate the instrument simultaneously in several tandem mass spectrometry (MS/MS) modes (e.g., full scan, product ion scan, reaction monitoring) significantly improves structural information content and sensitivity of analysis. For fingerprinting the oil spill, we constructed diagrams and conducted correlation studies that measure the similarity between environmental samples and enable us to differentiate the Macondo oil spill from other sources. PMID:27281271

  14. Scandium analysis in silicon-containing minerals by inductively coupled plasma tandem mass spectrometry

    Science.gov (United States)

    Whitty-Léveillé, Laurence; Drouin, Elisabeth; Constantin, Marc; Bazin, Claude; Larivière, Dominic

    2016-04-01

    This article reports on the development of a new method for the accurate and precise determination of the amount of scandium, Sc, in silicon-containing minerals, based on the use of tandem quadrupole inductively coupled plasma mass spectrometry (ICP-MS/MS). The tandem quadrupole instrument enables new mass filtering configurations, which can reduce polyatomic interferences during the determination of Sc in mineral matrices. He and O2 were used and compared as collision and reaction gases for the removal of interferences at m/z 45 and 61. Using helium gas was ineffective to overcome all of the spectral interferences observed at m/z 45 and particularly for Si-based interferences. However, conversion of Sc+ ions into ScO+ ions (after bombardment with O2 in the octopole reaction system coupled with the use of the instrument in MS/MS mass-shift mode) provided interference-free conditions and sufficiently low limits of detection, down to 3 ng L- 1, to accurately detect Sc. The accuracy of the proposed methodology was assessed by analyzing five different reference materials (BX-N, OKA-2, NIM-L, SY-3 and GH).

  15. A Supercritical Fluid Chromatography/Tandem Mass Spectrometry Method for the Simultaneous Quantification of Metformin and Gliclazide in Human Plasma

    OpenAIRE

    Agrawal Y; Gogoi P; Manna K; Bhatt H; Jain V

    2010-01-01

    Present study reports the development and validation of a simultaneous estimation of metformin and gliclazide in human plasma using supercritical fluid chromatography followed by tandem mass spectrometry. Acetonitrile:water (80:20) mixture was used as a mobile phase along with liquid CO 2 in supercritical fluid chromatography and phenformin as an internal standard. The modified plasma samples were analyzed by electro-spray ionization method in selective reaction monitoring mode in tandem mas...

  16. Design and performance of an instrument for electron impact tandem mass spectrometry and action spectroscopy of mass/charge selected macromolecular ions stored in RF ion trap*

    Science.gov (United States)

    Ranković, Milos Lj.; Giuliani, Alexandre; Milosavljević, Aleksandar R.

    2016-06-01

    A new apparatus was designed, coupling an electron gun with a linear quadrupole ion trap mass spectrometer, to perform m/ z (mass over charge) selected ion activation by electron impact for tandem mass spectrometry and action spectroscopy. We present in detail electron tracing simulations of a 300 eV electron beam inside the ion trap, design of the mechanical parts, electron optics and electronic circuits used in the experiment. We also report examples of electron impact activation tandem mass spectra for Ubiquitin protein, Substance P and Melittin peptides, at incident electron energies in the range from 280 eV to 300 eV.

  17. Quantitative analysis of tivantinib in rat plasma using ultra performance liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Bai, Yan-Li; Yuan, Hong-Chang; Zhang, Dong-Tao; Liu, Yuan; Zhang, Yin

    2016-07-15

    In this work, a simple, sensitive and fast ultra performance liquid chromatography with tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the quantitative determination of tivantinib in rat plasma. Plasma samples were processed with a protein precipitation. The separation was achieved by an Acquity UPLC BEH C18 (2.1mm×50mm, 1.7μm) column with a gradient mobile phase consisting of 0.1% formic acid in water and acetonitrile. Detection was carried out using positive-ion electrospray tandem mass spectrometry via multiple reaction monitoring (MRM). The validated method had an excellent linearity in the range of 1.0-100ng/mL (r(2)>0.9967) with a lower limit of quantification (1.0ng/mL). The extraction recovery was in the range of 79.4-84.2% for tivantinib and 80.3% for carbamazepine (internal standard, IS). The intra- and inter-day precision was below 8.9% and accuracy was from -7.2% to 9.5%. No notable matrix effect and astaticism was observed for tivantinib. The method has been successfully applied to a pharmacokinetic study of tivantinib in rats for the first time, which provides the basis for the further development and application of tivantinib. PMID:27179187

  18. Analysis of alcohols, as dimethylglycine esters, by electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Johnson, D W

    2001-03-01

    Dimethylglycine (DMG) esters are new derivatives for the rapid, sensitive and selective analysis of primary and secondary alcohols, in complex mixtures, by electrospray ionization tandem mass spectrometry (ESI-MS/MS). Their development was inspired by the use of the complementary dimethylaminoethyl esters for the trace, rapid analysis of fatty acids. DMG esters are simply prepared by heating a dichloromethane solution of the imidazolide of dimethylglycine, containing triethylamine, and an alcohol. DMG esters of long-chain fatty alcohols, isoprenoidal alcohols and hydroxy-acids are analysed by electrospray ionization tandem mass spectrometry with a precursor ion of m/z 104 scan. Diols, glyceryl esters, glyceryl ethers and some sterols are analysed by a neutral loss of 103 Da scan. Trimethylglycine (TMG) ester iodides, prepared by alkylation of DMG esters with methyl iodide, are more sensitive derivatives for molecules containing secondary alcohol groups, such as cholesterol and gibberellic acid. They are analysed by a precursor ion of m/z 118 scan. DMG or TMG derivatives were shown to be at least comparable and sometimes an order of magnitude more sensitive than N-methylpyridyl ether derivatives for ESI-MS/MS analysis of the different classes of alcohols. Applications of these derivatives for the diagnosis of inherited disorders and the analysis of natural products are presented. PMID:11312519

  19. Determination of biogenic amines in beer and wine by capillary electrophoresis-tandem mass spectrometry.

    Science.gov (United States)

    Daniel, Daniela; Dos Santos, Vagner Bezerra; Vidal, Denis Tadeu Rajh; do Lago, Claudimir Lucio

    2015-10-16

    A capillary electrophoresis-tandem mass spectrometry (CE-MS/MS) method for the simultaneous assessment of nine biogenic amines (spermine, spermidine, putrescine, cadaverine, histamine, phenylethylamine, tryptamine, tyramine, and urocanic acid) in commercial samples of beer and wine is introduced. The samples were submitted to a simple clean-up step with poly(vinylpolypyrrolidone) followed by filtration. Electrophoretic separation in a polyvinyl alcohol (PVA)-coated capillary using 0.5 mol L(-1) acetic acid (pH 2.5) as background electrolyte and detection by electrospray-tandem mass spectrometry was employed. The range of the correlation coefficients of the calibration curves of the analyzed compounds was 0.996-0.999, and the limits of detection and limits of quantification were in the range of 1-2 μg L(-1) and 3-8 μg L(-1), respectively. The recovery values for samples spiked at three concentration levels (0.2, 0.5, and 1.0 mg L(-1)) ranged from 87 to 113% with standard deviation not greater than 5.8%. The use of a PVA-coated silica capillary allows suppressing the electroosmotic flow and, consequently, increasing of the separation efficiency. The method was successfully used to determine biogenic amines in commercial samples of beer and wine. PMID:26362807

  20. Determination of parabens in serum by liquid chromatography-tandem mass spectrometry: Correlation with lipstick use.

    Science.gov (United States)

    Tahan, Gabriella Padovani; Santos, Nayara de Kássia Souza; Albuquerque, Ana Carolina; Martins, Isarita

    2016-08-01

    Parabens are the most widely used preservative and are considered to be relatively safe compounds. However, studies have demonstrated that they may have estrogenic activity, and there is ongoing debate regarding the safety and potential cancer risk of using products containing these compounds. In the present work, liquid chromatography-tandem mass spectrometry was applied to determine methylparaben and propylparaben concentrations in serum, and the results were correlated with lipstick application. Samples were analyzed using liquid-liquid extraction, followed by liquid chromatography-tandem mass spectrometry. The validation results demonstrated the linearity of the method over a range of 1-20 ng/mL, in addition to the method's precision and accuracy. A statistically significant difference was demonstrated between serum parabens in women who used lipstick containing these substances compared with those not using this cosmetic (p = 0.0005 and 0.0016, respectively), and a strong association was observed between serum parabens and lipstick use (Spearman correlation = 0.7202). PMID:27154569

  1. UPLC-MS/MS同时检测染发剂中三种二氨基酚类物质%Determinauon of 3 diaminopnenols in hair dyes by ultra performance liquid chromatography tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    曹鹏; 耿金培; 许红岩; 李晓玉; 李金强; 梁君妮; 沙美兰

    2011-01-01

    建立了超高效液相色谱-串联质谱( UPLC-MS/MS)同时检测染发剂中三种二氨基酚类物质(2,4-二氨基苯酚盐酸盐、2,4-二氨基苯甲醚盐酸盐、2,3-二氨基苯酚)含量的方法.样品经0.1%甲酸水溶液提取,正己烷净化后,用Waters ACQUITY BEH Shield RP18色谱柱进行分离,流动相为甲醇和5 mmol/L乙酸铵-0.1%甲酸溶液.分离后采用多反应监测模式进行检测,外标法定量.在优化实验条件下,三种化合物的线性范围为10 ~ 500.μg/L,相关系数均大于0.998.三种二氨基酚类化合物的检出限为3μg/kg,定量下限为10μg/kg,加标平均回收率为80.3%~113.5%,相对标准偏差均不高于8.6%.该方法适用于染发剂中三种二氨基酚类物质的定量及确证分析.%An ultra performance liquid chromatography-electrospray ionization triple-quadruple tandem mass speetrometric ( UPLC-ESI MS/MS) method has been established for the simultaneous determination of three diaminophenols, including 2,4-diaminophenol dihydrochloride, 2,4-diaminoanisole dihydrochloride, and 2,3-Diaminophenol, in hair dyes. The diaminophenols were extracted by water - 0. 1 % formic acid and cleaned up by n-hexane. The separation was carried out by an ACQUITY? BEH Shield RP18 column using methanol and 5 mmol/L ammonium acetate - 0. 1 % formic acid as the mobile phase. The target compounds were confirmed and quantified by MS-MS under multiple-reaction monitering ( MRM) mode with external standard method. Extraction and chromatographic conditions were optimized and the best separation was obtained. Under the optimal conditions, the calibration curves were linear in the range of 10 ~ 500 jxg/L for the three compounds with correlation coefficients more than 0.998. The limits of detection (LOD) were 3 fig/kg, and the limits of quantitation (LOQ) were 10 jxg/kg. The average recoveries of 3 diaminophenols were between 80.3% and 113. 5% with the relative standard deviations (RSDs) no more than 8

  2. Determination of Paralytic Shellfish Poisoning Toxins in Shellfish by Liquid Chromatography with Tandem Mass Spectrometry%液相色谱-串联质谱法检测贝类产品中麻痹性贝类毒素

    Institute of Scientific and Technical Information of China (English)

    母清林; 方杰; 王晓华; 胡颢琰; 曹柳燕; 张庆红

    2013-01-01

    建立了贝类组织中11种麻痹性贝类毒素的高效液相色谱-串联质谱分析方法,包括STX、dcSTX、NEO、dcNEO、GTX1-4、dcGTX2,3和GTX5(B1).贝类样品经含0.1%甲酸的80%(体积分数)乙腈水溶液超声提取后,经过冷冻分层,下层固体融化后通过HLB固相萃取小柱富集净化和10 000MWCO(Molecular Weight Cutoff)超滤管超滤截留,超滤液用于仪器分析.采用Zwitterionic亲水性相互作用色谱柱(250 mm×4.6 mm,5μm,德国)分离,在多反应监测模式下进行定性和定量分析.各组分在一定的范围内具有良好的线性关系,平均回收率大于60%,相对标准偏差小于20%(n=7).用该方法分析染毒的栉孔扇贝样品,证实了对PSP毒素具有良好的分析测定效果.%A liquid chromatography-electrospray ionization triple-quadruple tandem mass spectrometric method has been established for the determination of eleven kinds of paralytic shellfish poisoning toxins including STX, dcSTX, NEO, dcNEO, GTX1 -4, dcGTX2,3 andGTX5(B1). After being extracted using acetonitrile and water (80:20, V/V) including 0. 1 % formic acid, the solution was frozen to separate into two layers. To melt the solid, then the solution would be cleaned-up by solid phase extraction (SPE) on an Oasis HLB cartridge. In order to get rid of macromolecule compound, the sample was ultra filtrated with 10 000 MWCO ( Molecular Weight Cutoff) ultra-filtration device. The ultra-filtration solution would be analyzed. The sample would be separated on a Zwitterionic hydrophilic interaction liquid chromatography column ( 250 mm × 4. 6 mm, 5 μm ). The quantitative and confirmatory determinations of PSP were performed by multiple reactions monitoring mode. All components showed good linear relation in the suitable range. The mean recoveries were more than 60% and the relative standard deviations were less than 20% ( n = 7 ). The method has been applied to the analysis of samples contaminated with PSP toxins with

  3. Retarding potential and induction charge detectors in tandem for measuring the charge and mass of nanodroplets

    International Nuclear Information System (INIS)

    The determination of the mass of a nanoparticle via time-of-flight typically requires a direct measurement of its charge. This can be done with a differential retarding potential analyzer and an induction charge detector operating in tandem. The spectrometer described in this article selects a particle with a specified retarding potential from a beam and directs it to an induction charge detector where both its velocity and charge are measured. The retarding potential, velocity, and charge also yield the particle's mass. The particle is analyzed without the need to collect it, and therefore can be employed in a subsequent experiment. The high charge sensitivity of the induction charge detector and the capability for working at low retarding potentials make the characterization of electrosprayed nanodroplets possible for the first time.

  4. Functional group composition of ambient and source organic aerosols determined by tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    J. Dron

    2010-04-01

    Full Text Available The functional group composition of various organic aerosols (OA is being investigated using a recently developed analytical approach based on atmospheric pressure chemical ionisation-tandem mass spectrometry (APCI-MS/MS. The determinations of the three functional groups' contents are performed quantitatively by neutral loss (carboxylic and carbonyl groups and precursor ion (nitro groups scanning modes of a tandem mass spectrometer. Major organic aerosol sources are studied: vehicular emission and wood combustion for primary aerosol sources; and a secondary organic aerosol (SOA produced through photo-oxidation of o-xylene. The results reveal significant differences in the functional group contents of these source aerosols. The laboratory generated SOA is dominated by carbonyls while carboxylics are preponderate in the wood combustion particles. On the other hand, vehicular emissions are characterised by a strong nitro content. The total amount of the three functional groups accounted for 1.7% (vehicular to 13.5% (o-xylene photo-oxidation of the organic carbon. The diagnostic functional group ratios are then used to tentatively differentiate sources of particles collected in an urban background environment located in an Alpine valley (Chamonix, France during a strong winter pollution event. The three functional groups under study account for a total functionalisation rate of 2.2 to 3.8% of the organic carbon in this ambient aerosol, which is also dominated by carboxylic moieties. In this particular case study of a deep alpine valley during winter, we show that the nitro- and carbonyl-to-carboxylic diagnostic ratios can be a useful tool to distinguish the sources. In these conditions, the total OA concentrations are highly dominated by wood combustion OA. This result is confirmed by an organic markers source apportionment approach which assesses a wood burning organic carbon contribution of about 60%. Finally, examples of functional group mass

  5. Automated Glycan Sequencing from Tandem Mass Spectra of N-Linked Glycopeptides.

    Science.gov (United States)

    Yu, Chuan-Yih; Mayampurath, Anoop; Zhu, Rui; Zacharias, Lauren; Song, Ehwang; Wang, Lei; Mechref, Yehia; Tang, Haixu

    2016-06-01

    Mass spectrometry has become a routine experimental tool for proteomic biomarker analysis of human blood samples, partly due to the large availability of informatics tools. As one of the most common protein post-translational modifications (PTMs) in mammals, protein glycosylation has been observed to alter in multiple human diseases and thus may potentially be candidate markers of disease progression. While mass spectrometry instrumentation has seen advancements in capabilities, discovering glycosylation-related markers using existing software is currently not straightforward. Complete characterization of protein glycosylation requires the identification of intact glycopeptides in samples, including identification of the modification site as well as the structure of the attached glycans. In this paper, we present GlycoSeq, an open-source software tool that implements a heuristic iterated glycan sequencing algorithm coupled with prior knowledge for automated elucidation of the glycan structure within a glycopeptide from its collision-induced dissociation tandem mass spectrum. GlycoSeq employs rules of glycosidic linkage as defined by glycan synthetic pathways to eliminate improbable glycan structures and build reasonable glycan trees. We tested the tool on two sets of tandem mass spectra of N-linked glycopeptides cell lines acquired from breast cancer patients. After employing enzymatic specificity within the N-linked glycan synthetic pathway, the sequencing results of GlycoSeq were highly consistent with the manually curated glycan structures. Hence, GlycoSeq is ready to be used for the characterization of glycan structures in glycopeptides from MS/MS analysis. GlycoSeq is released as open source software at https://github.com/chpaul/GlycoSeq/ . PMID:27111718

  6. Diagnosing lysosomal storage diseases in a Brazilian non-newborn population by tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Guilherme Dotto Brand

    2013-11-01

    Full Text Available OBJECTIVES: High-throughput mass spectrometry methods have been developed to screen newborns for lysosomal storage disorders, allowing the implementation of newborn screening pilot studies in North America and Europe. It is currently feasible to diagnose Pompe, Fabry, Gaucher, Krabbe, and Niemann-Pick A/B diseases, as well as mucopolysaccharidosis I, by tandem mass spectrometry in dried blood spots, which offers considerable technical advantages compared with standard methodologies. We aimed to investigate whether the mass spectrometry methodology for lysosomal storage disease screening, originally developed for newborns, can also discriminate between affected patients and controls of various ages. METHODS: A total of 205 control individuals were grouped according to age and subjected to mass spectrometry quantification of lysosomal α-glucosidase, β-glucocerebrosidase, α-galactosidase, acid sphingomyelinase, galactocerebrosidase, and α−L-iduronidase activities. Additionally, 13 affected patients were analyzed. RESULTS: The median activities for each enzyme and each age group were determined. Enzyme activities were significantly lower in individuals aged older than 18 years compared with those in newborns. Affected patients presented enzymatic activities corresponding to less than 20% of the age-matched controls. CONCLUSIONS: Our data indicate that the mass spectrometry methodology can be used for the screening of lysosomal storage diseases in non-newborn patients. However, for some diseases, such as Fabry and mucopolysaccharidosis I, a combination of biochemical and clinical data may be necessary to achieve accurate diagnoses.

  7. Advanced Laser Architecture for Two-Step Laser Tandem Mass Spectrometer

    Science.gov (United States)

    Fahey, Molly E.; Li, Steven X.; Yu, Anthony W.; Getty, Stephanie A.

    2016-01-01

    Future astrobiology missions will focus on planets with significant astrochemical or potential astrobiological features, such as small, primitive bodies and the icy moons of the outer planets that may host diverse organic compounds. These missions require advanced instrument techniques to fully and unambiguously characterize the composition of surface and dust materials. Laser desorptionionization mass spectrometry (LDMS) is an emerging instrument technology for in situ mass analysis of non-volatile sample composition. A recent Goddard LDMS advancement is the two-step laser tandem mass spectrometer (L2MS) instrument to address the need for future flight instrumentation to deconvolve complex organic signatures. The L2MS prototype uses a resonance enhanced multi-photon laser ionization mechanism to selectively detect aromatic species from a more complex sample. By neglecting the aliphatic and inorganic mineral signatures in the two-step mass spectrum, the L2MS approach can provide both mass assignments and clues to structural information for an in situ investigation of non-volatile sample composition. In this paper we will describe our development effort on a new laser architecture that is based on the previously flown Lunar Orbiter Laser Altimeter (LOLA) laser transmitter for the L2MS instrument. The laser provides two discrete midinfrared wavelengths (2.8 m and 3.4 m) using monolithic optical parametric oscillators and ultraviolet (UV) wavelength (266 nm) on a single laser bench with a straightforward development path toward flight readiness.

  8. Mining Large Scale Tandem Mass Spectrometry Data for Protein Modifications Using Spectral Libraries.

    Science.gov (United States)

    Horlacher, Oliver; Lisacek, Frederique; Müller, Markus

    2016-03-01

    Experimental improvements in post-translational modification (PTM) detection by tandem mass spectrometry (MS/MS) has allowed the identification of vast numbers of PTMs. Open modification searches (OMSs) of MS/MS data, which do not require prior knowledge of the modifications present in the sample, further increased the diversity of detected PTMs. Despite much effort, there is still a lack of functional annotation of PTMs. One possibility to narrow the annotation gap is to mine MS/MS data deposited in public repositories and to correlate the PTM presence with biological meta-information attached to the data. Since the data volume can be quite substantial and contain tens of millions of MS/MS spectra, the data mining tools must be able to cope with big data. Here, we present two tools, Liberator and MzMod, which are built using the MzJava class library and the Apache Spark large scale computing framework. Liberator builds large MS/MS spectrum libraries, and MzMod searches them in an OMS mode. We applied these tools to a recently published set of 25 million spectra from 30 human tissues and present tissue specific PTMs. We also compared the results to the ones obtained with the OMS tool MODa and the search engine X!Tandem. PMID:26653734

  9. Application of accelerator mass spectrometry at the tandem facility of university of Tokyo

    International Nuclear Information System (INIS)

    The tandem Van de Graaff accelerator at the Research Center for Nuclear Science and Technology (RCNST), University of Tokyo, has been adapted for accelerator mass spectrometry (AMS) of long-lived radioisotopes, and at present, three isotopes, Be-10, C-14 and Al-26 are routinely measured. The present report gives an outline of the AMS system and some results on the nuclear reaction cross sections such as N-14(n, x)Be-10, Al-27(n, 2n)Al-27, O-16(γ, x)Be-10. Measurements of neutron-induced cross sections are first presented and discussed. The experiments consist of irradiation of targets with semi-monoenergetic neutrons at the INS SF cyclotron and subsequent measurements of the produced radioisotopes with AMS at the RCNST tandem accelerator facility. Photon-induced reactions are studied on light fragment emission. The measurements of photon-induced production yield seem to suggest that the Be-10/Be-7 ratio is higher in photon-induced reaction. (N.K.)

  10. Tandem Mass Spectrometry Detection of Quorum Sensing Activity in Multidrug Resistant Clinical Isolate Acinetobacter baumannii

    Directory of Open Access Journals (Sweden)

    Kok-Gan Chan

    2014-01-01

    Full Text Available Many Proteobacteria communicate via production followed by response of quorum sensing molecules, namely, N-acyl homoserine lactones (AHLs. These molecules consist of a lactone moiety with N-acyl side chain with various chain lengths and degrees of saturation at C-3 position. AHL-dependent QS is often associated with regulation of diverse bacterial phenotypes including the expression of virulence factors. With the use of biosensor and high resolution liquid chromatography tandem mass spectrometry, the AHL production of clinical isolate A. baumannii 4KT was studied. Production of short chain AHL, namely, N-hexanoyl-homoserine lactone (C6-HSL and N-octanoyl-homoserine lactone (C8-HSL, was detected.

  11. Protonation Sites, Tandem Mass Spectrometry and Computational Calculations of o-Carbonyl Carbazolequinone Derivatives

    Science.gov (United States)

    Martínez-Cifuentes, Maximiliano; Clavijo-Allancan, Graciela; Zuñiga-Hormazabal, Pamela; Aranda, Braulio; Barriga, Andrés; Weiss-López, Boris; Araya-Maturana, Ramiro

    2016-01-01

    A series of a new type of tetracyclic carbazolequinones incorporating a carbonyl group at the ortho position relative to the quinone moiety was synthesized and analyzed by tandem electrospray ionization mass spectrometry (ESI/MS-MS), using Collision-Induced Dissociation (CID) to dissociate the protonated species. Theoretical parameters such as molecular electrostatic potential (MEP), local Fukui functions and local Parr function for electrophilic attack as well as proton affinity (PA) and gas phase basicity (GB), were used to explain the preferred protonation sites. Transition states of some main fragmentation routes were obtained and the energies calculated at density functional theory (DFT) B3LYP level were compared with the obtained by ab initio quadratic configuration interaction with single and double excitation (QCISD). The results are in accordance with the observed distribution of ions. The nature of the substituents in the aromatic ring has a notable impact on the fragmentation routes of the molecules. PMID:27399676

  12. Tandem mass spectrometric characterization of the conversion of xylose to furfural

    International Nuclear Information System (INIS)

    Thermal decomposition of xylose into furfural under acidic conditions has been studied using tandem mass spectrometry. Two different Brønsted acids, maleic and sulfuric acids, were used to demonstrate that varying the Brønsted acid does not affect the mechanism of the reaction. Two selectively labeled xylose molecules, 1-13C and 5-13C-xyloses, were examined to determine which carbon atom is converted to the aldehyde carbon in furfural. This can be done by using tandem mass spectrometry since collision-activated dissociation (CAD) of protonated unlabeled furfural results in the loss of CO from the aldehyde moiety. The loss of a neutral molecule with MW of 29 Da (13CO) was observed for protonated furfural derived from 1-13C-labeled xylose while the loss of a neutral molecule with MW of 28 Da (CO) was observed for protonated furfural derived from 5-13C labeled xylose. These results support the hypothesis that the mechanism of formation of furfural under mildly hot acidic conditions involves an intramolecular rearrangement of protonated xylose into the pyranose form rather than into an open-chain form. - Highlights: • Mechanism of catalytic conversion of Xyl to furfural under acidic conditions was studied by MS/MS and partially labeled Xyl. • The type of acid does not have a strong influence on the mechanism of catalytic conversion of Xyl to furfural. • The mechanism of formation of furfural under mildly hot acidic conditions involves an intramolecular rearrangement of Xyl

  13. Plasma free and total carnitine measured in children by tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    J.H. Osorio

    2002-11-01

    Full Text Available Free and total carnitine quantification is important as a complementary test for the diagnosis of unusual metabolic diseases, including fatty acid degradation disorders. The present study reports a new method for the quantification of free and total carnitine in dried plasma specimens by isotope dilution electrospray tandem mass spectrometry with sample derivatization. Carnitine is determined by looking for the precursor of ions of m/z = 103 of N-butylester derivative, and the method is validated by comparison with radioenzymatic assay. We obtained an inter- and intra-day assay coefficient of variation of 4.3 and 2.3, respectively. Free and total carnitine was analyzed in 309 dried plasma spot samples from children ranging in age from newborn to 14 years using the new method, which was found to be suitable for calculating reference age-related values for free and total carnitine (less than one month: 19.3 ± 2.4 and 23.5 ± 2.9; one to twelve months: 28.8 ± 10.2 and 35.9 ± 11.4; one to seven years: 30.7 ± 10.3 and 38.1 ± 11.9; seven to 14 years: 33.7 ± 11.6, and 43.1 ± 13.8 µM, respectively. No difference was found between males and females. A significant difference was observed between neonates and the other age groups. We compare our data with reference values in the literature, most of them obtained by radioenzymatic assay. However, this method is laborious and time consuming. The electrospray tandem mass spectrometry method presented here is a reliable, rapid and automated procedure for carnitine quantitation.

  14. Clinical validation of cutoff target ranges in newborn screening of metabolic disorders by tandem mass spectrometry : A worldwide collaborative project

    NARCIS (Netherlands)

    McHugh, David M. S.; Cameron, Cynthia A.; Abdenur, Jose E.; Abdulrahman, Mahera; Adair, Ona; Al Nuaimi, Shahira Ahmed; Ahlman, Henrik; Allen, Jennifer J.; Antonozzi, Italo; Archer, Shaina; Au, Sylvia; Auray-Blais, Christiane; Baker, Mei; Bamforth, Fiona; Beckmann, Kinga; Pino, Gessi Bentz; Berberich, Stanton L.; Binard, Robert; Boemer, Francois; Bonham, Jim; Breen, Nancy N.; Bryant, Sandra C.; Caggana, Michele; Caldwell, S. Graham; Camilot, Marta; Campbell, Carlene; Carducci, Claudia; Cariappa, Rohit; Carlisle, Clover; Caruso, Ubaldo; Cassanello, Michela; Miren Castilla, Ane; Castineiras Ramos, Daisy E.; Chakraborty, Pranesh; Chandrasekar, Ram; Ramos, Alfredo Chardon; Cheillan, David; Chien, Yin-Hsiu; Childs, Thomas A.; Chrastina, Petr; Sica, Yuri Cleverthon; Cocho de Juan, Jose Angel; Elena Colandre, Maria; Cornejo Espinoza, Veronica; Corso, Gaetano; Currier, Robert; Cyr, Denis; Czuczy, Noemi; D'Apolito, Oceania; Davis, Tim; de Sain-Van der Velden, Monique G.; Delgado Pecellin, Carmen; Di Gangi, Iole Maria; Di Stefano, Cristina Maria; Dotsikas, Yannis; Downing, Melanie; Downs, Stephen M.; Dy, Bonifacio; Dymerski, Mark; Rueda, Inmaculada; Elvers, Bert; Eaton, Roger; Eckerd, Barbara M.; El Mougy, Fatma; Eroh, Sarah; Espada, Mercedes; Evans, Catherine; Fawbush, Sandy; Fijolek, Kristel F.; Fisher, Lawrence; Franzson, Leifur; Frazier, Dianne M.; Garcia, Luciana R. C.; Garcia-Valdecasas Bermejo, Maria Sierra; Gavrilov, Dimitar; Gerace, Rosemarie; Giordano, Giuseppe; Irazabal, Yolanda Gonzalez; Greed, Lawrence C.; Grier, Robert; Grycki, Elyse; Gu, Xuefan; Gulamali-Majid, Fizza; Hagar, Arthur F.; Han, Lianshu; Hannon, W. Harry; Haslip, Christa; Hassan, Fayza Abdelhamid; He, Miao; Hietala, Amy; Himstedt, Leslie; Hoffman, Gary L.; Hoffman, William; Hoggatt, Philis; Hopkins, Patrick V.; Hougaard, David M.; Hughes, Kerie; Hunt, Patricia R.; Hwu, Wuh-Liang; Hynes, June; Ibarra-Gonzalez, Isabel; Ingham, Cindy A.; Ivanova, Maria; Jacox, Ward B.; John, Catharine; Johnson, John P.; Jonsson, Jon J.; Karg, Eszter; Kasper, David; Klopper, Brenda; Katakouzinos, Dimitris; Khneisser, Issam; Knoll, Detlef; Kobayashi, Hirinori; Koneski, Ronald; Kozich, Viktor; Kouapei, Rasoul; Kohlmueller, Dirk; Kremensky, Ivo; la Marca, Giancarlo; Lavochkin, Marcia; Lee, Soo-Youn; Lehotay, Denis C.; Lemes, Aida; Lepage, Joyce; Lesko, Barbara; Lewis, Barry; Lim, Carol; Linard, Sharon; Lindner, Martin; Lloyd-Puryear, Michele A.; Lorey, Fred; Loukas, Yannis L.; Luedtke, Julie; Maffitt, Neil; Magee, J. Fergall; Manning, Adrienne; Manos, Shawn; Marie, Sandrine; Hadachi, Sonia Marchezi; Marquardt, Gregg; Martin, Stephen J.; Matern, Dietrich; Gibson, Stephanie K. Mayfield; Mayne, Philip; McCallister, Tonya D.; McCann, Mark; McClure, Julie; McGill, James J.; McKeever, Christine D.; McNeilly, Barbara; Morrissey, Mark A.; Moutsatsou, Paraskevi; Mulcahy, Eleanor A.; Nikoloudis, Dimitris; Norgaard-Pedersen, Bent; Oglesbee, Devin; Oltarzewski, Mariusz; Ombrone, Daniela; Ojodu, Jelili; Papakonstantinou, Vagelis; Reoyo, Sherly Pardo; Park, Hyung-Doo; Pasquali, Marzia; Pasquini, Elisabetta; Patel, Pallavi; Pass, Kenneth A.; Peterson, Colleen; Pettersen, Rolf D.; Pitt, James J.; Poh, Sherry; Pollak, Arnold; Porter, Cory; Poston, Philip A.; Price, Ricky W.; Queijo, Cecilia; Quesada, Jonessy; Randell, Edward; Ranieri, Enzo; Raymond, Kimiyo; Reddic, John E.; Reuben, Alejandra; Ricciardi, Charla; Rinaldo, Piero; Rivera, Jeff D.; Roberts, Alicia; Rocha, Hugo; Roche, Geraldine; Greenberg, Cheryl Rochman; Egea Mellado, Jose Maria; Jess Juan-Fita, Maria; Ruiz, Consuelo; Ruoppolo, Margherita; Rutledge, S. Lane; Ryu, Euijung; Saban, Christine; Sahai, Inderneel; Salazar Garcia-Blanco, Maria Isabel; Santiago-Borrero, Pedro; Schenone, Andrea; Schoos, Roland; Schweitzer, Barb; Scott, Patricia; Seashore, Margretta R.; Seeterlin, Mary A.; Sesser, David E.; Sevier, Darrin W.; Shone, Scott M.; Sinclair, Graham; Skrinska, Victor A.; Stanley, Eleanor L.; Strovel, Erin T.; Jones, April L. Studinski; Sunny, Sherlykutty; Takats, Zoltan; Tanyalcin, Tijen; Teofoli, Francesca; Thompson, J. Robert; Tomashitis, Kathy; Domingos, Mouseline Torquado; Torres, Jasmin; Torres, Rosario; Tortorelli, Silvia; Turi, Sandor; Turner, Kimberley; Tzanakos, Nick; Valiente, Alf G.; Vallance, Hillary; Vela-Amieva, Marcela; Vilarinho, Laura; von Doebeln, Ulrika; Vincent, Marie-Francoise; Vorster, B. Chris; Watson, Michael S.; Webster, Dianne; Weiss, Sheila; Wilcken, Bridget; Wiley, Veronica; Williams, Sharon K.; Willis, Sharon A.; Woontner, Michael; Wright, Katherine; Yahyaoui, Raquel; Yamaguchi, Seiji; Yssel, Melissa; Zakowicz, Wendy M.

    2011-01-01

    Purpose: To achieve clinical validation of cutoff values for newborn screening by tandem mass spectrometry through a worldwide collaborative effort. Methods: Cumulative percentiles of amino acids and acylcarnitines in dried blood spots of approximately 25-30 million normal newborns and 10,742 deiden

  15. Rapid detection of pesticides not amenable to multi-residue methods by flow injection-tandem mass spectrometry

    NARCIS (Netherlands)

    Mol, J.G.J.; Dam, van R.C.J.

    2014-01-01

    Flow injection combined with tandem mass spectrometry (MS/MS) was investigated for the rapid detection of highly polar pesticides that are not amenable to multi-residue methods because they do not partition into organic solvents and require dedicated chromatographic conditions. The pesticides includ

  16. Simplified analysis of glyphosate and aminomethylphosphonic acid in water, vegetation, and soil by liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    A simple, fast, efficient, and sensitive method was developed for analysis of glyphosate and its degradate, aminomethylphosphonic acid (AMPA), in water, vegetation, and soil. Aqueous extracts were passed through reverse phase and cation exchange columns and directly injected into a tandem mass spect...

  17. Determination of olanzapine in whole blood using simple protein precipitation and liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Marie Katrine Klose; Johansen, Sys Stybe

    2009-01-01

    A simple, sensitive, and reproducible liquid chromatography-tandem mass spectrometry method has been developed and validated for the quantification of the antipsychotic drug olanzapine in whole blood using dibenzepine as internal standard (IS). After acidic methanol-induced protein precipitation of...

  18. An Undergraduate Experiment for the Measurement of Perfluorinated Surfactants in Fish Liver by Liquid Chromatography-Tandem Mass Spectrometry

    Science.gov (United States)

    Stock, Naomi L.; Martin, Jonathan W.; Ye, Yun; Mabury, Scott A.

    2007-01-01

    A laboratory experiment that provides students a hands-on introduction to the specific techniques of liquid chromatography-tandem mass spectrometry (LC-MS/MS) and electrospray ionization is presented. The students can thus practice the analytical principles of sample extraction, detection, quantification, and quality control using a fresh fish…

  19. Probability-Based Pattern Recognition and Statistical Framework for Randomization: Modeling Tandem Mass Spectrum/Peptide Sequence False Match Frequencies

    Science.gov (United States)

    Estimating and controlling the frequency of false matches between a peptide tandem mass spectrum and candidate peptide sequences is an issue pervading proteomics research. To solve this problem, we designed an unsupervised pattern recognition algorithm for detecting patterns with various lengths fr...

  20. Variations in IBD (ACAD8) in children with elevated C4-carnitine detected by tandem mass spectrometry newborn screening

    DEFF Research Database (Denmark)

    Pedersen, Christina B; Bischoff, Claus; Christensen, Ernst; Simonsen, Henrik; Lund, Allan M; Young, Sarah P; Koeberl, Dwight D; Millington, David S; Roe, Charles R; Roe, Diane S; Wanders, Ronald J A; Ruiter, Jos P N; Keppen, Laura D; Stein, Quinn; Knudsen, Inga; Gregersen, Niels; Andresen, Brage S

    2006-01-01

    or compound heterozygous for variations in the IBD gene have been reported. We present IBD deficiency in an additional four newborns with elevated C(4)-carnitine identified by tandem mass spectrometry (MS/MS) screening in Denmark and the United States. Three showed urinary excretions of isobutyryl...

  1. Determination of kava lactones in food supplements by liquid chromatography-atmospheric pressure chemical ionisation tandem mass spectrometry

    NARCIS (Netherlands)

    Bobeldijk, I.; Boonzaaijer, G.; Spies-Faber, E.J.; Vaes, W.H.J.

    2005-01-01

    Reversed-phase liquid chromatography and detection with atmospheric pressure chemical ionisation tandem mass spectrometry was used for the determination of kava extracts in herbal mixtures. One percent of kava extract can be detected, corresponding to approximately 0.05-0.2 mg/g of the individual ka

  2. Structural Elucidation of DNA-Protein Crosslinks Using Reductive Desulfurization and Liquid Chromatography-Tandem Mass Spectrometry

    OpenAIRE

    Wickramaratne, Susith; Tretyakova, Natalia Y.

    2014-01-01

    Structural characterization of DNA-protein crosslinks involving cysteine using reductive desulfurization in combination with liquid chromatography-tandem mass spectrometry is highlighted. The novel approach was used to identify hydrolytically stable DNA-protein lesions involving alkylguanine DNA alkyltransferase (AGT).

  3. Profiling ABA metabolites in Nicotiana tabacum L. leaves by ultra-performance liquid chromatography–electrospray tandem mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Turečková, Veronika; Novák, Ondřej; Strnad, Miroslav

    2009-01-01

    Roč. 80, č. 1 (2009), s. 390-399. ISSN 0039-9140 R&D Projects: GA AV ČR KAN200380801 Institutional research plan: CEZ:AV0Z50380511 Keywords : Abscisic acid * Ultra-performance liquid chromatography (UPLC) * Tandem mass spectrometry (MS/MS) Subject RIV: EC - Immunology Impact factor: 3.290, year: 2009

  4. Preventive doping control analysis: Liquid and gas chromatography time-to-flight mass spectrometry for detection of designer steriods

    NARCIS (Netherlands)

    Georgakopoulos, C.G.; Vonaparti, A.; Stamou, M.; Kiousi, P.; Lyris, E.; Angelis, Y.S.; Tsoupras, G.; Wuest, B.; Nielen, M.W.F.; Panderi, I.; Koupparis, M.

    2007-01-01

    A new combined doping control screening method for the analysis of anabolic steroids in human urine using liquid chromatography/electrospray ionization orthogonal acceleration time-of-flight mass spectrometry (LCoaTOFMS) and gas chromatography/electron ionization orthogonal acceleration time-of-flig

  5. Determination of nitrofuran and chloramphenicol residues by high resolution mass spectrometry versus tandem quadrupole mass spectrometry.

    Science.gov (United States)

    Kaufmann, A; Butcher, P; Maden, K; Walker, S; Widmer, M

    2015-03-01

    An ultra-high performance liquid chromatography based method, coupled to high resolution mass spectrometry (UHPLC-HRMS), was developed to permit the detection and quantification of various nitrofuran and chloramphenicol residues in a number of animal based food products. This method is based on the hydrolysis of covalently bound metabolites and derivatization with 2-nitrobenzaldehyde. Clean-up is achieved by a liquid/liquid and a reversed phase/solid phase extraction. Not only are the four conventional nitrofurans (nitrofurantoin, furazolidone, nitrofurazone and furaltadone) detected, but also nifursol, nitrovin and nifuroxazide. Furthermore, an underivatizable nitrofuran (nifurpirinol) and another banned drug (chloramphenicol) can be quantified as well. The compounds are detected in the form of their precursor ions, [M+H](+) and [M-H](-), respectively. The mass resolving power of 70,000 FWHM, and the applied mass window ensure sufficient selectivity and sensitivity. Confirmation is obtained by monitoring the HRMS resolved product ions which were derived from the unit-mass resolved precursor ions. The multiplexing capability of the utilized Orbitrap instrument provides not only highly selective, but also sensitive confirmatory signals. This method has been validated according to the CD 2002/657/EC for the following matrices: muscle, liver, kidney, fish, honey, eggs and milk. PMID:25682427

  6. mMass as a Software Tool for the Annotation of Cyclic Peptide Tandem Mass Spectra

    Czech Academy of Sciences Publication Activity Database

    Niedermeyer, T. H. J.; Strohalm, Martin

    2012-01-01

    Roč. 7, č. 9 (2012), e44913. E-ISSN 1932-6203 R&D Projects: GA MŠk(CZ) ME10013 Institutional research plan: CEZ:AV0Z50200510 Keywords : cyclic peptides * nMass Subject RIV: CE - Biochemistry Impact factor: 3.730, year: 2012

  7. Functional group composition of ambient and source organic aerosols determined by tandem mass spectrometry

    International Nuclear Information System (INIS)

    The functional group composition of various organic aerosols (OA) is investigated using a recently developed analytical approach based on atmospheric pressure chemical ionisation-tandem mass spectrometry (APCIMS/MS). The determinations of three functional groups contents are performed quantitatively by neutral loss (carboxylic and carbonyl groups, R-COOH and R-CO-R' respectively) and precursor ion (nitro groups, R-NO2) scanning modes of a tandem mass spectrometer. Major organic aerosol sources are studied: vehicular emission and wood combustion for primary aerosol sources; and a secondary organic aerosol (SOA) produced through photooxidation of o-xylene. The results reveal significant differences in the functional group contents of these source aerosols. The laboratory generated SOA is dominated by carbonyls while carboxylics are preponderate in the wood combustion particles. On the other hand, vehicular emissions are characterised by a strong nitro content. The total amount of the three functional groups accounts for 1.7% (vehicular) to 13.5% (o-xylene photooxidation) of the organic carbon. Diagnostic functional group ratios are then used to tentatively discriminate sources of particles collected in an urban background environment located in an Alpine valley (Chamonix, France) during a strong winter pollution event. The three functional groups under study account for a total functionalization rate of 2.2 to 3.8% of the organic carbon in this ambient aerosol, which is also dominated by carboxylic moieties. In this particular case study of a deep alpine valley during winter, we show that the nitro- and carbonyl-to-carboxylic diagnostic ratios can be a useful tool to discriminate sources. In these conditions, the total OA concentrations are highly dominated by wood combustion OA. This result is confirmed by an organic markers source apportionment approach which assess a wood burning organic carbon contribution of about 60%. Finally, examples of functional group mass

  8. Functional group composition of ambient and source organic aerosols determined by tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    J. Dron

    2010-08-01

    Full Text Available The functional group composition of various organic aerosols (OA is investigated using a recently developed analytical approach based on atmospheric pressure chemical ionisation-tandem mass spectrometry (APCI-MS/MS. The determinations of three functional groups contents are performed quantitatively by neutral loss (carboxylic and carbonyl groups, R-COOH and R-CO-R´ respectively and precursor ion (nitro groups, R-NO2 scanning modes of a tandem mass spectrometer. Major organic aerosol sources are studied: vehicular emission and wood combustion for primary aerosol sources; and a secondary organic aerosol (SOA produced through photooxidation of o-xylene. The results reveal significant differences in the functional group contents of these source aerosols. The laboratory generated SOA is dominated by carbonyls while carboxylics are preponderate in the wood combustion particles. On the other hand, vehicular emissions are characterised by a strong nitro content. The total amount of the three functional groups accounts for 1.7% (vehicular to 13.5% (o-xylene photooxidation of the organic carbon. Diagnostic functional group ratios are then used to tentatively discriminate sources of particles collected in an urban background environment located in an Alpine valley (Chamonix, France during a strong winter pollution event. The three functional groups under study account for a total functionalisation rate of 2.2 to 3.8% of the organic carbon in this ambient aerosol, which is also dominated by carboxylic moieties. In this particular case study of a deep alpine valley during winter, we show that the nitro- and carbonyl-to-carboxylic diagnostic ratios can be a useful tool to discriminate sources. In these conditions, the total OA concentrations are highly dominated by wood combustion OA. This result is confirmed by an organic markers source apportionment approach which assess a wood burning organic carbon contribution of about 60

  9. Functional group composition of ambient and source organic aerosols determined by tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dron, J.; El Haddad, I.; Temime-Roussel, B.; Wortham, H.; Marchand, N. [Univ Aix Marseille, CNRS, Lab Chim Provence, Equipe Instrumentat and React Atmospher, UMR 6264, F-13331 Marseille 3 (France); Jaffrezo, J.L. [Univ Grenoble 1, CNRS, UMR 5183, Lab Glaciol and Geophys Environm, F-38402 St Martin Dheres (France)

    2010-07-01

    The functional group composition of various organic aerosols (OA) is investigated using a recently developed analytical approach based on atmospheric pressure chemical ionisation-tandem mass spectrometry (APCIMS/MS). The determinations of three functional groups contents are performed quantitatively by neutral loss (carboxylic and carbonyl groups, R-COOH and R-CO-R' respectively) and precursor ion (nitro groups, R-NO{sub 2}) scanning modes of a tandem mass spectrometer. Major organic aerosol sources are studied: vehicular emission and wood combustion for primary aerosol sources; and a secondary organic aerosol (SOA) produced through photooxidation of o-xylene. The results reveal significant differences in the functional group contents of these source aerosols. The laboratory generated SOA is dominated by carbonyls while carboxylics are preponderate in the wood combustion particles. On the other hand, vehicular emissions are characterised by a strong nitro content. The total amount of the three functional groups accounts for 1.7% (vehicular) to 13.5% (o-xylene photooxidation) of the organic carbon. Diagnostic functional group ratios are then used to tentatively discriminate sources of particles collected in an urban background environment located in an Alpine valley (Chamonix, France) during a strong winter pollution event. The three functional groups under study account for a total functionalization rate of 2.2 to 3.8% of the organic carbon in this ambient aerosol, which is also dominated by carboxylic moieties. In this particular case study of a deep alpine valley during winter, we show that the nitro- and carbonyl-to-carboxylic diagnostic ratios can be a useful tool to discriminate sources. In these conditions, the total OA concentrations are highly dominated by wood combustion OA. This result is confirmed by an organic markers source apportionment approach which assess a wood burning organic carbon contribution of about 60%. Finally, examples of functional

  10. Sequence verification of human creatine kinase (43 kDa) isozymes by high-resolution tandem mass spectrometry.

    OpenAIRE

    Wood, T D; Chen, L.H.; White, C de B; Babbitt, P C; Kenyon, G L; McLafferty, F W

    1995-01-01

    Amino acid sequencing by recombinant DNA technology, although dramatically useful, is subject to base reading errors, is indirect, and is insensitive to posttranslational processing. Mass spectrometry techniques can provide molecular weight data from even relatively large proteins for such cDNA sequences and can serve as a check of an enzyme's purity and sequence integrity. Multiply-charged ions from electrospray ionization can be dissociated to yield structural information by tandem mass spe...

  11. Direct Measurement of Free Estradiol in Human Serum and Plasma by Equilibrium Dialysis-Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Ray, Julie A; Kushnir, Mark M; Rockwood, Alan L; Meikle, A Wayne

    2016-01-01

    We describe a direct method of measurement of free estradiol using equilibrium dialysis followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Serum aliquots and internal standards are extracted by liquid-liquid extraction using methyl-tert-butyl ether (MTBE) followed by derivatization with dansyl chloride. An API 5500 mass spectrometer operated in positive electrospray mode is used for detection. PMID:26602122

  12. Identification of the Related Substances in Ampicillin Capsule by Rapid Resolution Liquid Chromatography Coupled with Electrospray Ionization Tandem Mass Spectrometry

    OpenAIRE

    Lei Zhang; Xian Long Cheng; Yang Liu; Miao Liang; Honghuan Dong; Beiran Lv; Wenning Yang; Zhiqiang Luo; Mingmin Tang

    2014-01-01

    Rapid Resolution Liquid Chromatography coupled with Electrospray Ionization Tandem Mass Spectrometry (RRLC-ESI-MSn) was used to separate and identify related substances in ampicillin capsule. The fragmentation behaviors of related substances were used to identify their chemical structures. Finally, a total of 13 related substances in ampicillin capsule were identified, including four identified components for the first time and three groups of isomers on the basis of the exact mass, fragmenta...

  13. Planetary In Situ Sample Analysis with Tandem Two-Step Laser Mass Spectrometry

    Science.gov (United States)

    Brinckerhoff, W. B.; Getty, S. A.; Cornish, T. J.; Ecelberger, S. A.; Li, X.; Merrill Floyd, M. A.; Arevalo, R.; Elsila, J.; Callahan, M. P.

    2012-12-01

    -) and organic moieties. Second, by focusing a separate "post-ionization" laser pulse just above the sample surface, we can achieve two-step laser mass spectrometry, or L2MS, in the same highly-miniaturized TOF-MS. L2MS enables selective analysis of aromatic organics even in the presence of a complex mineral matrix. Finally, by introducing an ion optical gate in the flight path, we are able to take advantage of the broad focusing capabilities of the "curved field" reflectron at the core of the TOF-MS to achieve pseudo-tandem structural analysis of selected organics. The high-speed gate is used to admit only the molecular ion/s of interest into the reflectron. Diagnostic fragments of the ion/s obtained through metastable decay or active collision-induced dissociation (CID) remain in focus despite having widely variable velocities and masses. As such even molecular isomers with differing fragmentation pathways may be distinguished through a series of pseudo-tandem mass spectra that could be obtained in an automatic process during a mission. The "real-world" benefits of these enhancements are being fully characterized using a set of synthetic and natural standard samples as well as several planetary analogs and meteorites.

  14. Analyses of Phytohormones in Coconut (Cocos Nucifera L. Water Using Capillary Electrophoresis-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Swee Ngin Tan

    2014-12-01

    Full Text Available Capillary electrophoresis (CE coupled with mass spectrometry (MS or tandem mass spectrometry (MS/MS is reported as an alternative and potentially useful method for the simultaneous analysis of various classes of phytohormones with diversified structures, including indole-3-acetic acid (IAA, indole-3-butyric acid (IBA, abscisic acid (ABA, gibberellic acid (GA, zeatin (Z, N6-benzyladenine (BA, α-naphthaleneacetic acid (NAA and 2,4-dichlorophenoxyacetic acid (2,4-D. The key to the CE-MS/MS analysis was based on electroosmotic flow reversal using a cationic polymer-coated capillary. Under optimum conditions, a baseline separation of eight phytohormones was accomplished within 30 min using 60 mM ammonium formate/formic acid buffer of pH 3.8 with −20 kV as the separation voltage. The accessibility of MS/MS together with the characterization by migration properties obtained by CE allows for the development of CE-MS/MS as an emerging potential method for the analysis of different classes of phytohormones in a single run. The utility of the CE-MS/MS method was demonstrated by the comprehensive screening of phytohormones in coconut (Cocos nucifera L. water after pre-concentration and purification through solid-phase extraction (SPE cartridge. IAA, ABA, GA and Z were detected and quantified in the purified coconut water extract sample.

  15. Analysis of aristolochic acids, aristololactams and their analogues using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Yu, Jie; Ma, Chao-Mei; Wang, Xuan; Shang, Ming-Ying; Hattori, Masao; Xu, Feng; Jing, Yu; Dong, Shi-Wen; Xu, Yu-Qiong; Zhang, Cui-Ying; Cai, Shao-Qing

    2016-08-01

    More than 80 aristolochic acids (AAs) and aristololactams (ALs) have been found in plants of the Aristolochiaceae family, but relatively few have been fully studied. The present study aimed at developing and validating a liquid chromatography tandem mass spectrometry (LC/MS(n)) for the analysis of these compounds. We characterized the fragmentation behaviors of 31 AAs, ALs, and their analogues via high performance liquid chromatography coupled with electrospray ionization mass spectrometry. We summarized their fragmentation rules and used these rules to identify the constituents contained in Aristolochia contorta, Ar. debilis, Ar. manshurensis, Ar. fangchi, Ar. cinnabarina, and Ar. mollissima. The AAs and ALs showed very different MS behaviors. In MS(1) of AAs, the characteristic pseudomolecular ions were [M + NH4](+), [M + H](+), and [M + H - H2O](+). However, only [M + H](+) was found in the MS(1) of ALs, which was simpler than that of AAs. Distinct MS(n)fragmentation patterns were found for AAs and ALs, showing the same skeleton among the different substituent groups. The distribution of the 31 constituents in the 6 species of Aristolochia genus was reported for the first time. 25 Analogues of AAs and ALs were detected in this genus. A hierarchical schemes and a calculating formula of the molecular formula of these nitrophenanthrene carboxylic acids and their lactams were proposed. In conclusion, this method could be applied to identification of similar unknown constituents in other plants. PMID:27608953

  16. Quantitative analysis of phenibut in rat brain tissue extracts by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Grinberga, Solveiga; Zvejniece, Liga; Liepinsh, Edgars; Dambrova, Maija; Pugovics, Osvalds

    2008-12-01

    Phenibut (3-phenyl-4-aminobutyric acid) is a gamma-aminobutyric acid mimetic drug, which is used clinically as a mood elevator and tranquilizer. In the present work, a rapid, selective and sensitive liquid chromatography-tandem mass spectrometry method for quantification of phenibut in biological matrices has been developed. The method is based on protein precipitation with acidic acetonitrile followed by isocratic chromatographic separation using acetonitrile-formic acid (0.1% in water; 8:92, v/v) mobile phase on a reversed-phase column. Detection of the analyte was performed by electrospray ionization mass spectrometry in multiple reaction monitoring mode with the precursor-to-product ion transition m/z 180.3 --> m/z 117.2. The calibration curve was linear over the concentration range 50-2000 ng/mL. The lower limit of quantification for phenibut in rat brain extracts was 50 ng/mL. Acceptable precision and accuracy were obtained over the whole concentration range. The validated method was successfully applied in a pharmacological study to analyze phenibut concentration in rat brain tissue extract samples. PMID:19034959

  17. Integrated gas and liquid chromatography tandem mass spectrometry for forensic engine lubricating oil identification

    International Nuclear Information System (INIS)

    This paper presented a method for rapid chemical characterization of engine lubricating oils. Motor oils typically contain up to 5 per cent additives, such as detergent, antifoamant, dispersant, emulsifier, antioxidant, friction modifier, colour stabilizer and corrosion inhibitors. Different lube oil products usually have either different additives in various concentrations. As such, the formulation of additives in lube oil products should provide fingerprint information for forensic oil identification. The characterization method used in this study was based on a newly developed fast solvent liquid-liquid sample extraction procedure that combined the use of both liquid chromatography tandem mass spectrometry (LC-MS) and gas chromatography-mass spectrometry (GC-MS) simultaneously together with gas chromatography flame ionization detection (GC-FID). The method was used on a blind sample testing of commercially available engine lubricating products. The sample extraction procedure involved extraction of additives into acidified acetonitrile, two hexane washes of hydrophobic components of lube oil, filtration, and dilution with solvents for GC and LC analysis. The new method proved to be rapid and easy to use. It enabled the identification of unknown additives and hydrocarbons in many different types of fresh lube oils. Further tests will be needed to determine if this method can be used on real-world weathered samples. The method is part of an ongoing effort to deal with mysterious chemical spills, an important aspect of environmental protection and emergency preparedness. 8 refs., 7 figs

  18. Electrospray-assisted laser desorption/ionization and tandem mass spectrometry of peptides and proteins.

    Science.gov (United States)

    Peng, Ivory X; Shiea, Jentaie; Ogorzalek Loo, Rachel R; Loo, Joseph A

    2007-01-01

    We have constructed an electrospray-assisted laser desorption/ionization (ELDI) source which utilizes a nitrogen laser pulse to desorb intact molecules from matrix-containing sample solution droplets, followed by electrospray ionization (ESI) post-ionization. The ELDI source is coupled to a quadrupole ion trap mass spectrometer and allows sampling under ambient conditions. Preliminary data showed that ELDI produces ESI-like multiply charged peptides and proteins up to 29 kDa carbonic anhydrase and 66 kDa bovine albumin from single-protein solutions, as well as from complex digest mixtures. The generated multiply charged polypeptides enable efficient tandem mass spectrometric (MS/MS)-based peptide sequencing. ELDI-MS/MS of protein digests and small intact proteins was performed both by collisionally activated dissociation (CAD) and by nozzle-skimmer dissociation (NSD). ELDI-MS/MS may be a useful tool for protein sequencing analysis and top-down proteomics study, and may complement matrix-assisted laser desorption/ionization (MALDI)-based measurements. PMID:17639579

  19. Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lu, Shijun; Tran, Buu N; Nelsen, Jamie L; Aldous, Kenneth M

    2009-08-15

    Mitragynine is the primary active alkaloid extracted from the leaves of Mitragyna speciosa Korth, a plant that originates in South-East Asia and is commonly known as kratom in Thailand. Kratom has been used for many centuries for their medicinal and psychoactive qualities, which are comparable to that of opiate-based drugs. Kratom abuse can lead to a detectable content of mitragynine residue in urine. Ultra trace amount of mitragynine in human urine was determined by a high performance liquid chromatography coupled to an electrospray tandem mass spectrometry (HPLC-ESI/MS/MS). Mitragynine was extracted by methyl t-butyl ether (MTBE) and separated on a HILIC column. The ESI/MS/MS was accomplished using a triple quadrupole mass spectrometer in positive ion detection and multiple reactions monitoring (MRM) mode. Ajmalicine, a mitragynine's structure analog was selected as internal standard (IS) for method development. Quality control (QC) performed at three levels 0.1, 1 and 5 ng/ml of mitragynine in urine gave mean recoveries of 90, 109, and 98% with average relative standard deviation of 22, 12 and 16%, respectively. The regression linearity of mitragynine calibration ranged from 0.01 to 5.0 ng/ml was achieved with correlation coefficient greater than 0.995. A detection limit of 0.02 ng/ml and high precision data within-day and between days analysis were obtained. PMID:19577523

  20. GC-MS/MS analysis of benzo(a)pyrene by ion trap tandem mass spectrometry

    International Nuclear Information System (INIS)

    The mass spectrometry using an ion trap tandem mass spectrometer has been investigated to find optimum conditions for the analysis of benzo(a)pyrene (3,4-benzpyrene). The applicability to a real soil sample was also investigated to verify the usefulness of the MS/MS (or collision induced dissociation, CID) analysis. The optimum CID condition was 1.5 and 0.45 for the RF excitation voltage and the q value, respectively. For comparison, CID and EI were applied to the analysis of a soil sample. CID analysis was more sensitive than EI analysis of the soil sample. The limit of detection (LOD) of benzo(a)pyrene was 3.18 ng mL-1 and 0.85 ng mL-1 for EI and MS/MS analysis, respectively. The precision at the soil sample for EI and CID showed relative standard deviations of 6.1% and 4.1%, respectively, and the concentrations were 168 μg kg-1 and 162 μg kg-1, respectively

  1. De novo sequencing of peptides from top-down tandem mass spectra

    Energy Technology Data Exchange (ETDEWEB)

    Vyatkina, Kira; Wu, Si; Dekker, Leendert J.; vanDuijn, Martijn M.; Liu, Xiaowen; Tolic, Nikola; Dvorkin, Mikhail; Alexandrova, Sonya; Luider, Theo N.; Pasa-Tolic, Ljiljana; Pevzner, Pavel A.

    2015-09-28

    De novo sequencing of proteins and peptides is one of the most important problems in mass spectrometry-driven proteomics. A variety of methods have been developed to accomplish this task from a set of bottom-up tandem (MS/MS) mass spectra. However, a more recently emerged top-down technology, now gaining more and more popularity, opens new perspectives for protein analysis and characterization, implying a need in efficient algorithms for processing this kind of MS/MS data. Here we describe a method that allows to retrieve from a set of top-down MS/MS spectra long and accurate sequence fragments of the proteins contained in a sample. To this end, we outline a strategy for generating high-quality sequence tags from top-down spectra, and introduce the concept of a T-Bruijn graph by adapting to the case of tags the notion of an A-Bruijn graph widely used in genomics. The output of the proposed approach represents the set of amino acid strings spelled out by optimal paths in the connected components of a T-Bruijn graph. We illustrate its performance on top-down datasets acquired from carbonic anhydrase 2 (CAH2) and the Fab region of alemtuzumab.

  2. Analysis of 2-methylthio-derivatives of isoprenoid cytokinins by liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    A sensitive and reliable high-performance liquid chromatographic method with tandem mass spectrometric detection has been developed and used for the determination of 2-methylthio-cytokinin derivatives produced by the phytopathogenic actinomycete Rhodococcus fascians. The cultivation medium containing secreted cytokinins was concentrated and subjected to a solid-phase extraction (C18 and ion-exchange). The purified samples were further separated and analyzed by HPLC-ESI-MS/MS. This allowed to achieve chromatographic resolution of six highly hydrophobic cytokinin species including 2-methylthio-isopentenyladenine, 2-methylthio-isopentenyladenosine, 2-methylthio-trans-zeatin and 2-methylthio-trans-zeatin riboside and their cis-isomers when a reversed-phase chromatographic column (C4) and a mobile phase consisting of acetonitrile and 20 mM ammonium formate, pH 5, were used. Quantification was performed by a standard isotope dilution method using a multiple-reaction monitoring (MRM) mode. In the MRM mode, limits of detection reached 20-30 fmol and linear ranges spanned four orders of magnitude. Recovery values were between 35% and 65% and the analytical accuracy between 95% and 149%. The proposed bioanalytical method, which takes advantage of effective chromatographic separation of six 2-methyltio-derivatives (including isomers of zeatin-type cytokinins) and sensitive mass spectrometric detection, may become useful for plant biologists studying the significance of these substances in plant-microbe interactions.

  3. Analysis of 2-methylthio-derivatives of isoprenoid cytokinins by liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tarkowski, Petr, E-mail: petr.tarkowski@upol.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Department of Biochemistry, Faculty of Science, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Vaclavikova, Katerina, E-mail: katka.vaclavik@seznam.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Department of Biochemistry, Faculty of Science, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Novak, Ondrej, E-mail: ondrej.novak@upol.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Pertry, Ine, E-mail: ine.pertry@ugent.BE [Department of Plant Biotechnology and Genetics, Ghent University, K.L.Ledeganckstraat 35, B-9000 Gent (Belgium); Hanus, Jan, E-mail: helehan@seznam.cz [Isotope Laboratory, Institute of Experimental Botany ASCR, Videnska 1083, 142 20 Prague (Czech Republic); Whenham, Robert [Apex Organics, Devon, England (United Kingdom); Vereecke, Danny, E-mail: danny.vereecke@hogent.BE [Department of Plant Production, University College Ghent, Ghent University, Schoonmeersstraat 52, B-9000 Gent (Belgium); Sebela, Marek, E-mail: marek.sebela@upol.cz [Department of Biochemistry, Faculty of Science, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Strnad, Miroslav, E-mail: miroslav.strnad@upol.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic)

    2010-11-08

    A sensitive and reliable high-performance liquid chromatographic method with tandem mass spectrometric detection has been developed and used for the determination of 2-methylthio-cytokinin derivatives produced by the phytopathogenic actinomycete Rhodococcus fascians. The cultivation medium containing secreted cytokinins was concentrated and subjected to a solid-phase extraction (C18 and ion-exchange). The purified samples were further separated and analyzed by HPLC-ESI-MS/MS. This allowed to achieve chromatographic resolution of six highly hydrophobic cytokinin species including 2-methylthio-isopentenyladenine, 2-methylthio-isopentenyladenosine, 2-methylthio-trans-zeatin and 2-methylthio-trans-zeatin riboside and their cis-isomers when a reversed-phase chromatographic column (C4) and a mobile phase consisting of acetonitrile and 20 mM ammonium formate, pH 5, were used. Quantification was performed by a standard isotope dilution method using a multiple-reaction monitoring (MRM) mode. In the MRM mode, limits of detection reached 20-30 fmol and linear ranges spanned four orders of magnitude. Recovery values were between 35% and 65% and the analytical accuracy between 95% and 149%. The proposed bioanalytical method, which takes advantage of effective chromatographic separation of six 2-methyltio-derivatives (including isomers of zeatin-type cytokinins) and sensitive mass spectrometric detection, may become useful for plant biologists studying the significance of these substances in plant-microbe interactions.

  4. Liquid chromatography-tandem mass spectrometry for analysis of intestinal permeability of loperamide in physiological buffer.

    Directory of Open Access Journals (Sweden)

    Miriam S Rubelt

    Full Text Available Analysis of in vitro samples with high salt concentrations represents a major challenge for fast and specific quantification with liquid chromatography-tandem mass spectrometry (LC-MS/MS. To investigate the intestinal permeability of opioids in vitro employing the Ussing chamber technique, we developed and validated a fast, sensitive and selective method based on LC-MS/MS for the determination of loperamide in HEPES-buffered Ringer's solution. Chromatographic separation was achieved with an Atlantis dC18 column, 2.1 mm×20 mm, 3 µm particle size and a gradient consisting of methanol/0.1% formic acid and ammonium acetate. The flow rate was 0.7 ml/min, and the total run time was 3 min. For quantification, two mass transitions for loperamide and a deuterated internal standard (methadone-d(3 were used. The lower limit of loperamide quantification was 0.2 ng/ml. This new LC-MS/MS method can be used for the detection of loperamide in any experimental setup using HEPES-buffered Ringer's solution as a matrix compound.

  5. Dynamic Bayesian Network for Accurate Detection of Peptides from Tandem Mass Spectra.

    Science.gov (United States)

    Halloran, John T; Bilmes, Jeff A; Noble, William S

    2016-08-01

    A central problem in mass spectrometry analysis involves identifying, for each observed tandem mass spectrum, the corresponding generating peptide. We present a dynamic Bayesian network (DBN) toolkit that addresses this problem by using a machine learning approach. At the heart of this toolkit is a DBN for Rapid Identification (DRIP), which can be trained from collections of high-confidence peptide-spectrum matches (PSMs). DRIP's score function considers fragment ion matches using Gaussians rather than fixed fragment-ion tolerances and also finds the optimal alignment between the theoretical and observed spectrum by considering all possible alignments, up to a threshold that is controlled using a beam-pruning algorithm. This function not only yields state-of-the art database search accuracy but also can be used to generate features that significantly boost the performance of the Percolator postprocessor. The DRIP software is built upon a general purpose DBN toolkit (GMTK), thereby allowing a wide variety of options for user-specific inference tasks as well as facilitating easy modifications to the DRIP model in future work. DRIP is implemented in Python and C++ and is available under Apache license at http://melodi-lab.github.io/dripToolkit . PMID:27397138

  6. Poiseuille flow-induced vibrations of two tandem circular cylinders with different mass ratios

    Science.gov (United States)

    Jiang, Ren-Jie; Lin, Jian-Zhong

    2016-06-01

    Flow-induced vibrations of two tandem circular cylinders with different mass ratios confined between two parallel walls are numerically studied via a lattice Boltzmann method. With fixed Reynolds number Re = 100 and blockage ratio β = 1/4, the effects of mass ratio m* = [0.0625, 16] and streamwise separation between two cylinders S/D = [1.125, 10] on the cylinder motions and vortex wake modes are investigated. A variety of distinct cylinder motion regimes involving the symmetric periodic vibration, biased quasi-periodic vibration, beating vibration, and steady regimes, with the corresponding wake structures, e.g., two rows of alternately rotating vortices, a single row of same-sign vortices, and steady wake, are observed. For each current case, the cylinder motion type is exclusive and in the binary oscillation regime, both cylinders always vibrate at a common primary frequency. The lighter cylinder usually oscillates at a larger amplitude than the heavier one, while the heavier cylinder undergoes larger lift force than the lighter one. The lift force and cylinder displacement always behave as an out-of-phase state. In the gap-interference region, large-amplitude oscillations could be produced extensively and in the wake-interference region, the cylinder motions and fluid flows are mainly dependent on the upstream cylinder. When the separation is large enough, both cylinders behave as two isolated ones. The mechanisms for the excitations of cylinder vibrations have also been analysed.

  7. Absolute quantification method and validation of airborne snow crab allergen tropomyosin using tandem mass spectrometry

    International Nuclear Information System (INIS)

    Measuring the levels of the major airborne allergens of snow crab in the workplace is very important in studying the prevalence of crab asthma in workers. Previously, snow crab tropomyosin (SCTM) was identified as the major aeroallergen in crab plants and a unique signature peptide was identified for this protein. The present study advances our knowledge on aeroallergens by developing a method of quantification of airborne SCTM by using isotope dilution mass spectrometry. Liquid chromatography tandem mass spectrometry was developed for separation and analysis of the signature peptides. The tryptic digestion conditions were optimized to accomplish complete digestion. The validity of the method was studied using international conference on harmonization protocol, Where 2-9% for CV (precision) and 101-110% for accuracy, at three different levels of quality control. Recovery of the spiked protein from PTFE and TopTip filters was measured to be 99% and 96%, respectively. To further demonstrate the applicability and the validity of the method for real samples, 45 kg of whole snow crab were processed in an enclosed (simulated) crab processing line and air samples were collected. The levels of SCTM ranged between 0.36-3.92 μg m-3 and 1.70-2.31 μg m-3 for butchering and cooking stations, respectively.

  8. Absolute quantification method and validation of airborne snow crab allergen tropomyosin using tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, Anas M. Abdel, E-mail: anasar@mun.ca [Department of Chemistry, Memorial University of Newfoundland, St. John' s, Newfoundland A1B 3X7 (Canada); Lopata, Andreas L. [School of Applied Science, Marine Biomedical Sciences and Health Research Group, RMIT University, Bundoora, 3083 Victoria (Australia); Randell, Edward W. [Department of Laboratory Medicine, Memorial University of Newfoundland, Eastern Health, St. John' s, Newfoundland and Labrador A1B 3V6 (Canada); Helleur, Robert J. [Department of Chemistry, Memorial University of Newfoundland, St. John' s, Newfoundland A1B 3X7 (Canada)

    2010-11-29

    Measuring the levels of the major airborne allergens of snow crab in the workplace is very important in studying the prevalence of crab asthma in workers. Previously, snow crab tropomyosin (SCTM) was identified as the major aeroallergen in crab plants and a unique signature peptide was identified for this protein. The present study advances our knowledge on aeroallergens by developing a method of quantification of airborne SCTM by using isotope dilution mass spectrometry. Liquid chromatography tandem mass spectrometry was developed for separation and analysis of the signature peptides. The tryptic digestion conditions were optimized to accomplish complete digestion. The validity of the method was studied using international conference on harmonization protocol, Where 2-9% for CV (precision) and 101-110% for accuracy, at three different levels of quality control. Recovery of the spiked protein from PTFE and TopTip filters was measured to be 99% and 96%, respectively. To further demonstrate the applicability and the validity of the method for real samples, 45 kg of whole snow crab were processed in an enclosed (simulated) crab processing line and air samples were collected. The levels of SCTM ranged between 0.36-3.92 {mu}g m{sup -3} and 1.70-2.31 {mu}g m{sup -3} for butchering and cooking stations, respectively.

  9. Drug screening of whole blood by ultra-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Oiestad, Elisabeth Leere; Johansen, Unni; Oiestad, Ase Marit Leere; Christophersen, Asbjørg Solberg

    2011-06-01

    An ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method for screening of drugs in whole blood has been developed and validated. Samples were prepared by supported liquid-liquid extraction on ChemElute(®) columns with ethyl acetate/heptane (4:1). LC separation was achieved with an Acquity HSS T3-column (2.1 100 mm, 1.8-μm particle). Mass detection was performed by positive ion mode electrospray MS-MS and included the following drugs/metabolites: morphine, codeine, ethyl morphine, oxycodone, buprenorphine, methadone, cocaine, methylphenidate, amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA), Δ(9)-tetrahydrocannabinol (THC), fentanyl, alprazolam, bromazepam, clonazepam, diazepam, nordiazepam, 3-OH-diazepam, fenazepam, flunitrazepam, lorazepam, nitrazepam, oxazepam, zopiclone, zolpidem, carisoprodol, and meprobamate. The cycle time was 9 min, and within- and between-day relative coefficients of variation varied from 1% to 33% and 2% to 58%, respectively. Extraction recoveries from whole blood were > 50% except for morphine and THC. The limit of quantitation was 0.1 to 521 ng/mL, depending on the drug. PMID:21619723

  10. Modeling protein tandem mass spectrometry data with an extended linear regression strategy.

    Science.gov (United States)

    Liu, Han; Bonner, Anthony J; Emili, Andrew

    2004-01-01

    Tandem mass spectrometry (MS/MS) has emerged as a cornerstone of proteomics owing in part to robust spectral interpretation algorithm. The intensity patterns presented in mass spectra are useful information for identification of peptides and proteins. However, widely used algorithms can not predicate the peak intensity patterns exactly. We have developed a systematic analytical approach based on a family of extended regression models, which permits routine, large scale protein expression profile modeling. By proving an important technical result that the regression coefficient vector is just the eigenvector corresponding to the least eigenvalue of a space transformed version of the original data, this extended regression problem can be reduced to a SVD decomposition problem, thus gain the robustness and efficiency. To evaluate the performance of our model, from 60,960 spectra, we chose 2,859 with high confidence, non redundant matches as training data, based on this specific problem, we derived some measurements of goodness of fit to show that our modeling method is reasonable. The issues of overfitting and underfitting are also discussed. This extended regression strategy therefore offers an effective and efficient framework for in-depth investigation of complex mammalian proteomes. PMID:17270923

  11. Characterization of wheat gliadin proteins by combined two-dimensional gel electrophoresis and tandem mass spectrometry.

    Science.gov (United States)

    Mamone, Gianfranco; Addeo, Francesco; Chianese, Lina; Di Luccia, Aldo; De Martino, Alessandra; Nappo, Annunziata; Formisano, Annarita; De Vivo, Pasqualina; Ferranti, Pasquale

    2005-07-01

    A proteomics-based approach was used for characterizing wheat gliadins from an Italian common wheat (Triticum aestivum) cultivar. A two-dimensional gel electrophoresis (2-DE) map of roughly 40 spots was obtained by submitting the 70% alcohol-soluble crude protein extract to isoelectric focusing on immobilized pH gradient strips across two pH gradient ranges, i.e., 3-10 or pH 6-11, and to sodium dodecyl sulfate-polyacrylamide electrophoresis in the second dimension. The chymotryptic digest of each spot was characterized by matrix-assisted laser desorption/ionization-time of flight mass spectrometry and nano electrospray ionization-tandem mass spectrometry (MS/MS) analysis, providing a "peptide map" for each digest. The measured masses were subsequently sought in databases for sequences. For accurate identification of the parent protein, it was necessary to determine de novo sequences by MS/MS experiments on the peptides. By partial mass fingerprinting, we identified protein molecules such as alpha/beta-, gamma-, omega-gliadin, and high molecular weight-glutenin. The single spots along the 2-DE map were discriminated on the basis of their amino acid sequence traits. alpha-Gliadin, the most represented wheat protein in databases, was highly conserved as the relative N-terminal sequence of the components from the 2-DE map contained only a few silent amino acid substitutions. The other closely related gliadins were identified by sequencing internal peptide chains. The results gave insight into the complex nature of gliadin heterogeneity. This approach has provided us with sound reference data for differentiating gliadins amongst wheat varieties. PMID:15952231

  12. A high-throughput de novo sequencing approach for shotgun proteomics using high-resolution tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Banfield Jillian F

    2010-03-01

    Full Text Available Abstract Background High-resolution tandem mass spectra can now be readily acquired with hybrid instruments, such as LTQ-Orbitrap and LTQ-FT, in high-throughput shotgun proteomics workflows. The improved spectral quality enables more accurate de novo sequencing for identification of post-translational modifications and amino acid polymorphisms. Results In this study, a new de novo sequencing algorithm, called Vonode, has been developed specifically for analysis of such high-resolution tandem mass spectra. To fully exploit the high mass accuracy of these spectra, a unique scoring system is proposed to evaluate sequence tags based primarily on mass accuracy information of fragment ions. Consensus sequence tags were inferred for 11,422 spectra with an average peptide length of 5.5 residues from a total of 40,297 input spectra acquired in a 24-hour proteomics measurement of Rhodopseudomonas palustris. The accuracy of inferred consensus sequence tags was 84%. According to our comparison, the performance of Vonode was shown to be superior to the PepNovo v2.0 algorithm, in terms of the number of de novo sequenced spectra and the sequencing accuracy. Conclusions Here, we improved de novo sequencing performance by developing a new algorithm specifically for high-resolution tandem mass spectral data. The Vonode algorithm is freely available for download at http://compbio.ornl.gov/Vonode.

  13. Integrated Post-Experiment Monoisotopic Mass Refinement: An Integrated Approach to Accurately Assign Monoisotopic Precursor Masses to Tandem Mass Spectrometric Data

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hee-Jung; Purvine, Samuel O.; Kim, Hokeun; Petyuk, Vladislav A.; Hyung, Seok-Won; Monroe, Matthew E.; Mun, Dong-Gi; Kim, Kyong-Chul; Park, Jong-Moon; Kim, Su-Jin; Tolic, Nikola; Slysz, Gordon W.; Moore, Ronald J.; Zhao, Rui; Adkins, Joshua N.; Anderson, Gordon A.; Lee, Hookeun; Camp, David G.; Yu, Myeong-Hee; Smith, Richard D.; Lee, Sang-Won

    2010-10-15

    Accurate assignment of monoisotopic precursor masses to tandem mass spectrometric (MS/MS) data is a fundamental and critically important step for successful peptide identifications in mass spectrometry based proteomics. Here we describe an integrated approach that combines three previously reported methods of treating MS/MS data for precursor mass refinement. This combined method, “integrated Post-Experiment Monoisotopic Mass Refinement” (iPE MMR), integrates steps: 1) generation of refined MS/MS data by DeconMSn, 2) additional refinement of the resultant MS/MS data by a modified version of PE-MMR, and 3) elimination of systematic errors of precursor masses using DtaRefinery. iPE-MMR is the first method that utilizes all MS information from multiple MS scans of a precursor ion and multiple charge states of it in an MS scan to determine precursor mass. By combining the synergistic features of each of method, iPE MMR increases sensitivity in peptide identification and provides increased accuracy when applied to complex high-throughput proteomics data. iPE MMR also allows incorporating additional data processing step(s) or skipping step(s), if necessary, to enable new developments or applications of the tools, as each step of iPE MMR produces output data in a common and conventional format used in proteomics data processing.

  14. Analysis of perfluoroalkyl substances in cord blood by turbulent flow chromatography coupled to tandem mass spectrometry

    International Nuclear Information System (INIS)

    A fast on-line analytical method based on turbulent flow chromatography (TFC) in combination with tandem mass spectrometry has been applied for the first time for the analysis of eighteen perfluoroalkyl substances (PFASs), in cord blood. A simple and rapid sample pre-treatment was optimised consisting on protein precipitation of 100 μL of sample with acetonitrile (1:1) followed by centrifugation during 10 min. The method was adapted to be sensitive enough and robust with minimum sample injection volume requirements (20 μL). The optimised methodology presented method limits of detection (MLOD) between 0.031 and 0.76 μg/L, detection capabilities (CCα) in the range between 0.005 and 0.99 μg/L and decision limits (CCβ) ranging from 0.006 to 1.16 μg/L. The recoveries in blank blood were calculated by spiking experiments with a mixture of 18 PFASs and established between 70 and 126% for most of compounds. Isotopic dilution was carried out for quantification of selected analytes. In-house validation of this new approach was carried out according to the requirements in the 2002/657/EC Decision. Finally the good applicability of this new approach was proved by the analysis of 60 cord blood samples from two different Mediterranean cities, Barcelona (Spain) and Heraklion (Greece). Ions perfluorohexanesulfonate (PFHxS) and perfluorooctanesulfonate (PFOS) were found at highest concentration and the more frequently compounds were PFHxS, PFOS and perfluorooctanoic acid (PFOA). The newly developed method proved to be suitable for large-scale epidemiologic studies, and to the data on PFASs exposure during pregnancy. -- Highlights: ► An on-line method has been developed for the analysis of 18 perfluoroalkyl substances. ► The method is based on turbulent flow chromatography tandem mass spectrometry. ► The method was applied in 60 cord blood samples from 2 Mediterranean cities. ► Acidic compounds were more frequently found and the method was proved to be suitable for

  15. Analysis of perfluoroalkyl substances in cord blood by turbulent flow chromatography coupled to tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Llorca, Marta; Perez, Francisca [Department of Environmental Chemistry, IDAEA-CSIC, Barcelona (Spain); Farre, Marinella, E-mail: mfuqam@cid.csic.es [Department of Environmental Chemistry, IDAEA-CSIC, Barcelona (Spain); Agramunt, Silvia [Centre for Research in Environmental Epidemiology (CREAL), Barcelona (Spain); IMIM (Hospital del Mar Research Institute), Barcelona (Spain); Kogevinas, Manolis [Centre for Research in Environmental Epidemiology (CREAL), Barcelona (Spain); IMIM (Hospital del Mar Research Institute), Barcelona (Spain); CIBER Epidemiologia y Salud Publica (CIBERESP), Barcelona (Spain); National School of Public Health, Athens (Greece); Barcelo, Damia [Department of Environmental Chemistry, IDAEA-CSIC, Barcelona (Spain); Catalan Institute for Water Research (ICRA), Girona (Spain); King Saud University, Riyadh (Saudi Arabia)

    2012-09-01

    A fast on-line analytical method based on turbulent flow chromatography (TFC) in combination with tandem mass spectrometry has been applied for the first time for the analysis of eighteen perfluoroalkyl substances (PFASs), in cord blood. A simple and rapid sample pre-treatment was optimised consisting on protein precipitation of 100 {mu}L of sample with acetonitrile (1:1) followed by centrifugation during 10 min. The method was adapted to be sensitive enough and robust with minimum sample injection volume requirements (20 {mu}L). The optimised methodology presented method limits of detection (MLOD) between 0.031 and 0.76 {mu}g/L, detection capabilities (CC{alpha}) in the range between 0.005 and 0.99 {mu}g/L and decision limits (CC{beta}) ranging from 0.006 to 1.16 {mu}g/L. The recoveries in blank blood were calculated by spiking experiments with a mixture of 18 PFASs and established between 70 and 126% for most of compounds. Isotopic dilution was carried out for quantification of selected analytes. In-house validation of this new approach was carried out according to the requirements in the 2002/657/EC Decision. Finally the good applicability of this new approach was proved by the analysis of 60 cord blood samples from two different Mediterranean cities, Barcelona (Spain) and Heraklion (Greece). Ions perfluorohexanesulfonate (PFHxS) and perfluorooctanesulfonate (PFOS) were found at highest concentration and the more frequently compounds were PFHxS, PFOS and perfluorooctanoic acid (PFOA). The newly developed method proved to be suitable for large-scale epidemiologic studies, and to the data on PFASs exposure during pregnancy. -- Highlights: Black-Right-Pointing-Pointer An on-line method has been developed for the analysis of 18 perfluoroalkyl substances. Black-Right-Pointing-Pointer The method is based on turbulent flow chromatography tandem mass spectrometry. Black-Right-Pointing-Pointer The method was applied in 60 cord blood samples from 2 Mediterranean cities

  16. Characterization of N-Succinylation of L-Lysylphosphatidylglycerol in Bacillus subtilis Using Tandem Mass Spectrometry

    Science.gov (United States)

    Atila, Metin; Katselis, George; Chumala, Paulos; Luo, Yu

    2016-08-01

    Phospholipids generally dominate in bacterial lipids. The negatively charged nature of phospholipids renders bacteria susceptible to cationic antibiotic peptides. In comparison with Gram-negative bacteria, Gram-positive bacteria in general have much less zwitterionic phosphatidylethanolamine. However, they are known for producing aminoacylated phosphatidylglycerol (PG), especially positively charged uc(l)-lysyl-PG, which is catalyzed by lysyl-PG synthase MprF, which appears to have a broad range of specificity for uc(l)-aminoacyl transfer RNAs. In addition, many Gram-positive bacteria also have a dlt-gene-coded uc(d)-alanylation pathway for lipoteichoic acids and wall teichoic acids covalently attached to a glycolipid or peptidoglycan. uc(d)-Alanylation also masks the dominant negative charge of the phosphate-rich polymers of teichoic acids. Using mass spectrometry, we have recently observed that precursor scans in negative mode for deprotonated amino acid fragments were most sensitive for ester-linked amino acids. Such a scan for precursors generating an m/z 145 lysyl anion revealed lysyl-PG as well as an additional species 100 m/z units greater than lysyl-PG. This unexpected species corresponded precisely to the expected mass of N-succinylated lysyl-PG. Tandem mass spectrometry revealed a precise match to the fragmentation pattern of this putative new species. PG, lysyl-PG, and N-succinyl-lysyl-PG may form a complete loop of charge reversal from -1 to +1 and then back to -1. Analogous charge reversal by N-succinylation of lysine residues in the bacterial as well as eukaryotic proteomes has been recently discovered as a major posttranslational modification. Such modification in bacterial lipids is possibly catalyzed by an enzyme homologous to the enzymes that modify lysine residues in proteins.

  17. Quantitative analysis of positional isomers of triacylglycerols via electrospray ionization tandem mass spectrometry of sodiated adducts.

    Science.gov (United States)

    Herrera, Lisandra Cubero; Potvin, Michael A; Melanson, Jeremy E

    2010-09-01

    Herein we report a reversed-phase high-performance liquid chromatography tandem mass spectrometry (RP-HPLC/MS/MS) method for the analysis of positional isomers of triacylglycerols (TAGs) in vegetable oils. The fragmentation behavior of [M + X](+) ions (X = NH(4), Li, Na or Ag) was studied on a quadrupole-time-of-flight (Q-TOF) mass spectrometer under low-energy collision-induced dissociation (CID) conditions. Mass spectra that were dependent on the X(+) ion and the nature and position of the acyl substituents were observed for four pairs of 'AAB/ABA'-type TAGs, namely PPO/POP, OOP/OPO, LLO/LOL and OOL/OLO (where P is 16:0, palmitic acid; O is 18:1, oleic acid; and L is 18:2, linoleic acid). For the majority of [M + X](+) adducts, the loss of the fatty acid in the outer positions (sn-1 or sn-3) was favored over the loss in the central position (sn-2), which enabled the determination of the fractional abundance of the isomers. Ratios of the intensity of fragment ions at various AAB/ABA compositions produced linear calibration curves with positive slopes, comparable to those obtained traditionally by ESI-MS/MS of [M + NH(4)](+) adducts. The only exceptions were the [M + Ag](+) adducts of the PPO/POP system, which produced calibration curves with negative slopes. Sodium adducts provided the most consistent level of isomeric discrimination for the TAGs studied and also offered the most convenience in that they required no additive to the mobile phase. Therefore, calibration curve data derived from [M + Na](+) adducts were applied to the quantification of TAG regioisomers in sunflower and olive oils. The regiospecific analysis showed that palmitic acid was typically located at positions sn-1 or sn-3, whereas unsaturated fatty acids, oleic and linoleic acids were mostly found at the sn-2 position. PMID:20814981

  18. Development of a high-performance liquid chromatography - Tandem mass spectrometry urinary pterinomics workflow.

    Science.gov (United States)

    Burton, Casey; Shi, Honglan; Ma, Yinfa

    2016-07-13

    Pteridines have evoked considerable interest from the scientific community owing to their prominent roles in human health and disease. The availability of analytical methodologies suitable for comprehensive pteridine profiling, termed here as "pterinomics", has been limited by inconsistent sample preparation and the exclusion of lesser studied pteridine derivatives. In response, the present study describes a new pterinomics workflow using a high-performance liquid chromatography - tandem mass spectrometry (HPLC-MS/MS) methodology for the simultaneous analysis of 15 pteridine derivatives including four structural isomers, marking the largest quantitative pteridine panel that has been studied to-date. The validated method possessed excellent sensitivity with method detection limits (0.025 μg L(-1) to 0.5 μg L(-1)) that were comparable or superior to existing techniques. Spiked recovery studies demonstrated the technique was both accurate (88-112%) and precise (RSD: 0-6%). A comparative study of commonly used oxidative pretreatments, including triiodide, permanganate, and manganese dioxide, revealed that the oxidative mechanisms were inefficient, complex, and concentration dependent. Finally, 50 clinical urine specimens were examined with the new technique wherein 10 pteridine derivatives were quantified and population ranges have been given. This technique can be used to examine pteridine molecular epidemiology and biochemistry to support related research applications, and may further be readily extended to include additional pteridine derivatives and biological matrices for specific applications. PMID:27237839

  19. Differentiating Isobaric Steroid Hormone Metabolites Using Multi-Stage Tandem Mass Spectrometry

    Science.gov (United States)

    Tedmon, Lauren; Barnes, Jeremy S.; Nguyen, Hien P.; Schug, Kevin A.

    2013-03-01

    Steroid hormones and their metabolites are currently undergoing clinical trials as potential therapeutics for traumatic brain injury (TBI). To support this work, it is necessary to develop improved procedures for differentiating isobaric species in this compound class. Equilin sulfate (E-S), estrone sulfate (E1-S), 17α-dihydroequilin sulfate (ADHE-S), and 17β-dihydroequilin sulfate (BDHE-S) are primary constituents in hormone replacement therapies, such as Premarin, which are among pharmaceuticals being investigated for TBI treatment. The latter three compounds are isomers and can be difficult to differentiate in trace analytical determinations. In this work, a systematic study of the fragmentation of ADHE-S, BDHE-S, E1-S, and E-S under different stages of higher order tandem mass spectrometry (MSn) and variation of collision energy, allowed optimization of conditions for distinguishing the isomeric structures. For epimeric variants (e.g., ADHE-S versus BDHE-S; α- versus β-stereoisomerization in the C-17 position), differentiation was achieved at MS4 and fragmentation was demonstrated through MS5. Computational analysis was performed to further explore differences in the fragmentation pathways due to changes in stereochemistry.

  20. [Determination of gossypol in edible vegetable oil with high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Zhang, Wenhua; Huang, Chaoqun; Xie, Wen; Shen, Li

    2014-06-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of gossypol in edible vegetable oil. The sample was extracted with ethyl alcohol by vortex-excited oscillation. The extract was cleaned up by 0.22 microm filter membrane and centrifuged for 5 min at 4 000 r/min after standing in a fridge at 4 degrees C for 30 min. The compound was separated on a C18 column (100 mm x 2.1 mm, 3.5 microm) with acetonitrile and 1% (v/v) formic acid aqueous solution as mobile phase. The detection of gossypol was carried out by LC-MS/MS with positive electrospray ionization under multiple reaction monitoring (MRM) mode using external standard method. The limits of quantification (S/N > 10) of gossypol in edible vegetable oil was 1 mg/kg. The recoveries were from 87.4% to 100% at the spiked levels of 1, 2, 200 mg/kg of gossypol in edible vegetable oil with the relative standard deviations (RSDs) between 3.9% and 12.2%. The method, with high sensitivity, good precision and high recovery, was suitable for the confirmation and quantification of gossypol residue in edible vegetable oil. PMID:25269254

  1. Multiresidue Analysis of Pesticides in Straw Roughage by Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Zhang, Zihao; Feng, Mengyuan; Zhu, Kechen; Han, Lijun; Sapozhnikova, Yelena; Lehotay, Steven J

    2016-08-10

    A multiresidue analytical method using a modification of the "quick, easy, cheap, effective, rugged, and safe" (QuEChERS) sample preparation approach combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis was established and validated for the rapid determination of 69 pesticides at different levels (1-100 ng/g) in wheat and rice straws. In the quantitative analysis, the recoveries ranged from 70 to 120%, and consistent RSDs ≤ 20% were achieved for most of the target analytes (53 pesticides in wheat straw and 58 in rice straw). Almost all of the analytes achieved good linearity with R(2) > 0.98, and the limit of validation levels (LVLs) for diverse pesticides ranged from 1 to 10 ng/g. Different extraction and cleanup conditions were evaluated in both types of straw, leading to different options. The use of 0.1% formic acid or not in extraction with acetonitrile yielded similar final outcomes, but led to the use of a different sorbent in dispersive solid-phase extraction. Both options are efficient and useful for the multiresidue analysis of targeted pesticides in wheat and rice straw samples. PMID:26881844

  2. Determination of the Thyreostats in Animal Feeding Stuffs Using Liquid Chromatography-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Woźniak Barbara

    2014-10-01

    Full Text Available A rapid liquid chromatography tandem mass spectrometry method was developed and validated to detect and confirm five thyreostatic drugs: tapazole, thiouracil, methylthiouracil, propylthiouracil, and phenylthiouracil in animal feeding stuff samples. Thyreostats were extracted from feed with methanol, and then degreasing of the extract with petroleum ether was performed, followed by the derivatisation of the compounds with 3-iodobenzylbromide in basic medium (pH 8.0. The derivatives were extracted with diethyl ether and analysed by gradient elution on a Poroshell 120-EC C18 column with triple quadrupole MS detection with turbo spray source in positive ionisation mode. The method was validated in accordance with the Commission Decision 2002/657/EC. For validation level of 10 ļig kg-1, the recovery ranged from 82% to 97.5% for all examined compounds. The repeatability and reproducibility did not exceed the limit of 20% for all analytes. The linearity was good for all thyreostats in the whole range of tested concentrations, as proved by the correlation coefficients greater than 0.99. The decision limits (CCa ranged from 1.63 ļig kg-1 to 3.95 ļig kg-1, whereas the detection capabilities (CCß ranged from 2.74 ļig kg-1 to 6.73 ļig kg-1. The developed analysis is sensitive and robust, and therefore useful for quantification and confirmation of thyreostats in residue control programme.

  3. A method for profiling gangliosides in animal tissues using electrospray ionization-tandem mass spectrometry.

    Science.gov (United States)

    Tsui, Zhao-Chun; Chen, Qi-Rui; Thomas, Michael J; Samuel, Michael; Cui, Zheng

    2005-06-15

    Gangliosides are critical in many functions of mammalian cells but present as a minor lipid component with many molecular species of subtle differences. Conventional strategies for profiling gangliosides suffer from poor reproducibility, low sensitivity, and low-throughput capacity. Prior separation of gangliosides by thin-layer chromatography and/or high-performance liquid chromatography not only was laborious and tedious but also could introduce uneven losses of molecular species. We developed a new strategy of using electrospray ionization-tandem mass spectrometry (ESI-MS/MS) to profile gangliosides with high-throughput potential. This strategy involves three new findings: (i) collision-induced fragmentation of gangliosides gave rise to a common ion of m/z 290, a derivative of N-acetylneuraminic acid; (ii) phospholipids exert a profound suppression of ganglioside detection in ESI-MS/MS to prevent a direct detection in total cellular lipid extracts; and (iii) enrichment of gangliosides in the aqueous phase from total cellular lipid extracts eliminates the damping effect of phospholipids and permits direct precursor scan. PMID:15907870

  4. Development of a dedicated peptide tandem mass spectral library for conservation science.

    Science.gov (United States)

    Fremout, Wim; Dhaenens, Maarten; Saverwyns, Steven; Sanyova, Jana; Vandenabeele, Peter; Deforce, Dieter; Moens, Luc

    2012-05-30

    In recent years, the use of liquid chromatography tandem mass spectrometry (LC-MS/MS) on tryptic digests of cultural heritage objects has attracted much attention. It allows for unambiguous identification of peptides and proteins, and even in complex mixtures species-specific identification becomes feasible with minimal sample consumption. Determination of the peptides is commonly based on theoretical cleavage of known protein sequences and on comparison of the expected peptide fragments with those found in the MS/MS spectra. In this approach, complex computer programs, such as Mascot, perform well identifying known proteins, but fail when protein sequences are unknown or incomplete. Often, when trying to distinguish evolutionarily well preserved collagens of different species, Mascot lacks the required specificity. Complementary and often more accurate information on the proteins can be obtained using a reference library of MS/MS spectra of species-specific peptides. Therefore, a library dedicated to various sources of proteins in works of art was set up, with an initial focus on collagen rich materials. This paper discusses the construction and the advantages of this spectral library for conservation science, and its application on a number of samples from historical works of art. PMID:22560279

  5. Determination of ractopamine in pig hair using liquid chromatography with tandem mass spectrometric detection.

    Science.gov (United States)

    Wu, Junlin; Liu, Xiaoyun; Peng, Yunping

    2014-01-01

    A quantitative analytical procedure for the determination of ractopamine in pig hair has been developed and validated. The hair samples were washed and incubated at 75°C with isoxuprine and hair extraction buffer. The drug present was quantified using mixed solid-phase extraction and liquid chromatography with tandem mass spectrometric detection. The limit of quantization (LOQ) was 10pg/mg and the intra-day precision at 25pg/mg and 750pg/mg was 0.49% and 2.8% respectively. Inter-day precision was 0.88% and 3.52% at the same concentrations. The hair extraction percentage recovery at 25pg/mg and 50ng/mL was 99.47% and 103.83% respectively. The extraction percentage recovery at 25pg/mg and 50ng/mg was 93.52% and 100.26% respectively. Our results showed that ractopamine residues persist in hair in 24days of withdrawal and also showed the possibility to test ractopamine from pig hair samples. PMID:24548851

  6. Selective extraction and determination of neonicotinoid insecticides in wine by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Rodríguez-Cabo, T; Casado, J; Rodríguez, I; Ramil, M; Cela, R

    2016-08-19

    A simplified, high throughput procedure for the determination of five neonicotinoid insecticides in red and white wines, using liquid chromatography (LC)-tandem mass spectrometry (MS/MS), is presented. The effects of different experimental parameters (extraction sorbent, solvent elution and clean-up conditions) in the efficiency and the selectivity of the sample preparation process were assessed through calculation of the extraction yields and the matrix effects (MEs). Wines (10mL) were concentrated using OASIS HLB cartridges, on-line connected to Florisil clean-up cartridges, with acetonitrile serving as the elution solvent. The extract (5mLvol) was concentrated to 1mL and injected in the LC-ESI-MS/MS system. The optimized procedure provided quantitative extraction yields at the same time that the efficiency of ESI ionization remained unchanged between standards and sample extracts. Overall recoveries, calculated against authentic standards in ACN, varied between 77 and 119% and the attained limits of quantification remained below 0.2ngmL(-1). Analysis of commercial wines revealed imidacloprid residues in more than 50% of processed samples, with a maximum level of 14ngmL(-1). PMID:27425763

  7. Metabolism profiles of nuciferine in rats using ultrafast liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Ye, Lin-Hu; Xiao, Bing-Xin; Liao, Yong-Hong; Liu, Xin-Min; Pan, Rui-Le; Chang, Qi

    2016-08-01

    Nuciferine (NF) is one of the main aporphine alkaloids existing in the traditional Chinese medicine Folium Nelumbinis (lotus leaves). Modern pharmacological studies have demonstrated that NF has a broad spectrum of bioactivities, such as anti-HIV and anti-hyperlipidemic effects, and has been recommended as a leading compound for new drug development. However, the metabolites and biotransformation pathway of NF in vivo have not yet been comprehensively investigated. The present study was performed to identify the metabolites of NF for exploring in vivo fates. Rat plasma and urine samples were collected after oral administration and prepared by liquid-liquid extraction with ethyl acetate. A method based on ultrafast liquid chromatography with tandem mass spectrometry was applied to identify the metabolites. Q1 (first quadrupole) full scan combined with a multiple reaction monitoring (MRM) survey scan were used for the detection of metabolites. MRM-information-dependent acquisition of enhanced product ions was used for the structural identification of detected metabolites. A total of 10 metabolites were identified, including phase I (demethylation, oxidation and dehydrogenation) and phase II (glucuronidation, sulfation and glutathione) biotransformation products. Demethylation is the main metabolic pathway of NF in the body. These results can help in improving understanding of the disposition and pharmacological mechanism of NF in the body. Copyright © 2016 John Wiley & Sons, Ltd. PMID:26682724

  8. Measurement of phthalates diesters in food using gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Cariou, Ronan; Larvor, Frédéric; Monteau, Fabrice; Marchand, Philippe; Bichon, Emmanuelle; Dervilly-Pinel, Gaud; Antignac, Jean-Philippe; Le Bizec, Bruno

    2016-04-01

    An analytical strategy dedicated to 4 major phthalate diesters (DiBP, DnBP, BBzP and DEHP) monitoring in food items has been developed and validated according to normalized guidelines. The method has been applied to a wide range of foodstuffs (n=54) to generate first-ever occurrence data at the French level. This method involves separation and detection using gas chromatography coupled to tandem mass spectrometry, in electron ionisation with highly specific selected reaction monitoring, quantification being performed according to the isotope dilution principle. A particular attention has been paid to background contamination management at any stage of the analytical process, from the sampling to the expression of the results. Limits of reporting, defined as statistically different from background contamination, were found to be 2.7, 0.53, 0.18 and 3.4 μg kg(-1), and relative combined uncertainties were finally found to be 7.6%, 12.2%, 12.0% and 14.1%, for DiBP, DnBP, BBzP and DEHP, respectively. PMID:26593485

  9. Simultaneous determination of cosmetics ingredients in nail products by fast gas chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Wanlong; Wang, Perry G; Wittenberg, James B; Rua, Diego; Krynitsky, Alexander J

    2016-05-13

    A rapid and sensitive gas chromatography with tandem mass spectrometry (GC-MS/MS) method has been developed and validated to quantitatively determine cosmetic ingredients, such as toluene, N-methylpyrrolidone, 2,4-dihydroxybenzophenone (benzophenone-1, BP-1), and diethylene glycol dimethacrylate, in nail products. In this procedure, test portions were extracted with acetone, followed by vortexing, sonication, centrifugation, and filtration. During the extraction procedure, BP-1 was derivatized making it amenable to GC-MS analysis, using N,O-​bis(trimethylsilyl)​trifluoroacetamide. The four ingredients were quantified by GC-MS/MS in an electron ionization mode. Four corresponding stable isotopically labeled analogues were selected as internal standards, which were added at the beginning of the sample preparation to correct for recoveries and matrix effects. The validated method was used to screen 34 commercial nail products for these four cosmetic ingredients. The most common ingredients detected in the nail products were toluene and BP-1. Toluene was detected in 26 products and ranged from 1.36 to 173,000μg/g. BP-1 ranged from 18.3 to 2,370μg/g in 10 products. PMID:27083261

  10. Aflatoxin M1 determination in cheese by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Cavaliere, Chiara; Foglia, Patrizia; Guarino, Chiara; Marzioni, Francesca; Nazzari, Manuela; Samperi, Roberto; Laganà, Aldo

    2006-12-01

    A new method for determining aflatoxin M1 (AFM1) in cheese by liquid chromatography-tandem mass spectrometry has been developed. Two methodologies were compared for sample extraction. The first one involves sample extraction with dichloromethane for hard, aged cheese or acetone for fresh cheese and includes a preliminary matrix solid-phase dispersion-extraction step before solid-phase extraction (SPE) clean-up by a Carbograph-4 cartridge. The second method uses a water/methanol solution (90:10, v/v) extraction at 150 degrees C before clean-up. The average recoveries of AFM1 from samples spiked at levels of 0.25-0.45 microg/kg, were 81-92% and the precision (RSD) ranged from 3 to 7% with the first method, whilst the average recoveries were 79-84%, and RSD ranged from 7 to 15% for the second method. Due to different matrix effect, the quantification limits were 0.019-0.025 microg/kg in the first case and 0.048-0.143 microg/kg in the second one, depending on cheese typology. PMID:17056052

  11. Multiresidue analysis of environmental pollutants in edible vegetable oils by gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Rui-Ze; Jiang, Jie; Mao, Ting; Zhao, Ya-Song; Lu, Yong

    2016-09-15

    A novel multiresidue determination of polycyclic aromatic hydrocarbons (PAHs), phthalate esters (PAEs) and alkylphenols (APs) in edible vegetable oils was developed. The samples were extracted with hexane-saturated acetonitrile, and after concentration, the extract was directly qualitatively and quantitatively analyzed by gas chromatography-tandem mass spectrometry (GC-MS/MS) with multiple reaction monitoring (MRM) in positive ion mode. The calibration curve displayed good linearity in the range of 2-100μg/L, with correlation coefficients greater than 0.99. The mean recoveries were 70.0-110.8% by analysis of spiked oil, and the relative standard deviations (RSDs) were 2.1-10.2% (n=6), respectively. The limits of detection (LODs) for the 23 PAHs, 17 PAEs and 3 APs were 0.1-1.0μg/kg, 0.1-4.0μg/kg and 1.2-3.0μg/kg, respectively. The established method effectively avoided interference from large amounts of lipids and pigments. It was applied to real sample and shown to be a rapid and reliable alternative for determination and confirmation in routine analysis. PMID:27080878

  12. Differential Proteomic Analysis of Human Saliva using Tandem Mass Tags Quantification for Gastric Cancer Detection.

    Science.gov (United States)

    Xiao, Hua; Zhang, Yan; Kim, Yong; Kim, Sung; Kim, Jae Joon; Kim, Kyoung Mee; Yoshizawa, Janice; Fan, Liu-Yin; Cao, Cheng-Xi; Wong, David T W

    2016-01-01

    Novel biomarkers and non-invasive diagnostic methods are urgently needed for the screening of gastric cancer to reduce its high mortality. We employed quantitative proteomics approach to develop discriminatory biomarker signatures from human saliva for the detection of gastric cancer. Salivary proteins were analyzed and compared between gastric cancer patients and matched control subjects by using tandem mass tags (TMT) technology. More than 500 proteins were identified with quantification, and 48 of them showed significant difference expression (p < 0.05) between normal controls and gastric cancer patients, including 7 up-regulated proteins and 41 down-regulated proteins. Five proteins were selected for initial verification by ELISA and three were successfully verified, namely cystatin B (CSTB), triosephosphate isomerase (TPI1), and deleted in malignant brain tumors 1 protein (DMBT1). All three proteins could differentiate gastric cancer patients from normal control subjects, dramatically (p < 0.05). The combination of these three biomarkers could reach 85% sensitivity and 80% specificity for the detection of gastric cancer with accuracy of 0.93. This study provides the proof of concept of salivary biomarkers for the non-invasive detection of gastric cancer. It is highly encouraging to turn these biomarkers into an applicable clinical test after large scale validation. PMID:26911362

  13. Comprehensive characterization of anticoagulant rodenticides in sludge by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Gómez-Canela, Cristian; Lacorte, Silvia

    2016-08-01

    The occurrence of 10 commonly used anticoagulant rodenticides in centrifuged sludge of 27 wastewater treatment plants was evaluated using solid-liquid extraction (SLE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Activated carbon, alumina, and Florisil cartridges with methanol/dichloromethane as eluting solvents were tested in combination with primary-secondary amine (PSA) to optimize an efficient sample cleanup. PSA in combination with Florisil was the best methodology to extract anticoagulant rodenticides in sludge providing recoveries between 42 ± 0.5 and 100 ± 2 %. Warfarin, bromadiolone, ferulenol, and coumachlor were the most ubiquitous compounds in sludge at concentrations up to 84.2 ng g(-1) for the latter. Coumatetralyl, dicoumarol, and brodifacoum were detected sporadically at levels between 6.1 and 17.4 ng g(-1). On the contrary, acenocoumarol, difenacoum, and flocoumafen were not detected in any sample. Finally, we estimated the amount of anticoagulant rodenticides discharged via sludge in order to determine the potential impact to agricultural soil according to different sludge usage practices in the region investigated. This study demonstrates that anticoagulant rodenticides are accumulated in sludge during activated sludge treatment and that the application of sludge as fertilizers may pose a future environmental risk, if not controlled. PMID:27146526

  14. Determination of gestagens in kidney fat by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Lõhmus, Madis; Kender, Tiia

    2007-03-14

    The use of gestagens in animal fattening is prohibited within the European Union. Recently, the use of spectrometric methods for the detection and confirmation of banned substances was made obligatory. Therefore, conventional high-performance liquid chromatographic (HPLC) methods have been superseded. It has been possible to couple a previously described HPLC method for the determination of acetyl-gestagens in kidney fat to tandem mass spectrometry (LC-MS/MS). The decision limits CCalpha and the detection capability CCbeta are found to be below the minimum required performance limit (MRPL) established for medroxyprogesterone acetate (MPA) at 1 microg kg(-1). The calculated values for CCalpha are as follows: megestrol acetate (MGA)--0.15 microg kg(-1), melengesterol acetate (MLA)--0.15 microg kg(-1), chlormadinone acetate (CMA)--0.37 microg kg(-1) and for medroxyprogesterone acetate (MPA)--0.24 microg kg(-1). The CCbeta values for these compounds have been determined as 0.19, 0.19, 0.47 and 0.32 microg kg(-1), respectively. PMID:17386717

  15. A rapid quantitative method of carisoprodol and meprobamate by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Essler, Shannon; Bruns, Kerry; Frontz, Michael; McCutcheon, J Rod

    2012-11-01

    The identification and quantitation of carisoprodol (Soma) and its chief metabolite meprobamate, which is also a clinically prescribed drug, remains a challenge for forensic toxicology laboratories. Carisoprodol and meprobamate are notable for their widespread use as muscle relaxants and their frequent identification in the blood of impaired drivers. Routine screening is possible in both an acidic/neutral pH screen and a traditional basic screen. An improvement in directed testing quantitations was desirable over the current options of an underivatized acidic/neutral extraction or a basic screen, neither of which used ideal internal standards. A new method was developed that utilized a simple protein precipitation, deuterated internal standards and a short 2-min isocratic liquid chromatography separation, followed by multiple reaction monitoring with tandem mass spectrometry. The linear quantitative range for carisoprodol was determined to be 1-35mg/L and for meprobamate was 0.5-50mg/L. The method was validated for specificity and selectivity, matrix effects, and accuracy and precision. PMID:23040985

  16. An iterative algorithm to quantify factors influencing peptide fragmentation during tandem mass spectrometry.

    Science.gov (United States)

    Yu, Chungong; Lin, Yu; Sun, Shiwei; Cai, Jinjin; Zhang, Jingfen; Bu, Dongbo; Zhang, Zhuo; Chen, Runsheng

    2007-04-01

    In protein identification by tandem mass spectrometry, it is critical to accurately predict the theoretical spectrum for a peptide sequence. To date, the widely-used database searching methods adopted simple statistical models for predicting. For some peptide, these models usually yield a theoretical spectrum with a significant deviation from the experimental one. In this paper, in order to derive an improved predicting model, we utilized a non-linear programming model to quantify the factors impacting peptide fragmentation. Then, an iterative algorithm was proposed to solve this optimization problem. Upon a training set of 1803 spectra, the experimental result showed a good agreement with some known principles about peptide fragmentation, such as the tendency to cleave at the middle of peptide, and Pro's preference of the N-terminal cleavage. Moreover, upon a testing set of 941 spectra, comparison of the predicted spectra against the experimental ones showed that this method can generate reasonable predictions. The results in this paper can offer help to both database searching and de novo methods. PMID:17589963

  17. Endogenous glucocorticoid analysis by liquid chromatography-tandem mass spectrometry in routine clinical laboratories.

    Science.gov (United States)

    Hawley, James M; Keevil, Brian G

    2016-09-01

    Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a powerful analytical technique that offers exceptional selectivity and sensitivity. Used optimally, LC-MS/MS provides accurate and precise results for a wide range of analytes at concentrations that are difficult to quantitate with other methodologies. Its implementation into routine clinical biochemistry laboratories has revolutionised our ability to analyse small molecules such as glucocorticoids. Whereas immunoassays can suffer from matrix effects and cross-reactivity due to interactions with structural analogues, the selectivity offered by LC-MS/MS has largely overcome these limitations. As many clinical guidelines are now beginning to acknowledge the importance of the methodology used to provide results, the advantages associated with LC-MS/MS are gaining wider recognition. With their integral role in both the diagnosis and management of hypo- and hyperadrenal disorders, coupled with their widespread pharmacological use, the accurate measurement of glucocorticoids is fundamental to effective patient care. Here, we provide an up-to-date review of the LC-MS/MS techniques used to successfully measure endogenous glucocorticoids, particular reference is made to serum, urine and salivary cortisol. PMID:27208627

  18. Confirmation and quantification of clenbuterol in horse urine using liquid chromatography tandem mass spectrometry triple quadrupole.

    Science.gov (United States)

    Bishop, Jennifer; Heffron, Brendan; Taddei, Lisa; Benoit, Marc; Hurt, Laura; Costello, Sara; Gross, Melissa; Negrusz, Adam

    2015-03-01

    Clenbuterol (CLE) is used in horses as a bronchodilator and for its anabolic steroid-like effects. CLE is a Class 3 drug according to current Association of Racing Commissioners International (ARCI) Uniform Classification Guidelines. The Racing Medication and Testing Consortium recommended a urine CLE threshold of 140 pg/mL after careful scientific review of the results of studies describing the disposition of CLE in the horse and this threshold was adopted by the ARCI. Enzyme-linked immunosorbent assay was previously used to screen samples for CLE in Illinois, but could not detect such low concentrations in urine. Thus, a liquid-liquid extraction of CLE from urine followed by quantification by liquid chromatography-tandem mass spectrometry was developed and validated. Method validation included testing stability, ion suppression and enhancement, precision, accuracy and uncertainty. Intra-, interday and total precision and accuracy were calculated for each control and found to be within the ±15% acceptance range. The Guide to the Expression of Uncertainty in Measurement approach was used to calculate uncertainty, which was 11% at the 95% confidence level. In the past 5 years, only 15 samples were reported as positive for CLE in Illinois. This new method was used in a pilot program to screen and confirm samples received from thoroughbred and harness horses. PMID:25505053

  19. Determination of Residual Acrylamide in Medical Polyacrylamide Hydrogel by High Performance Liquid Chromatography tandem Mass Spectroscopy

    Institute of Scientific and Technical Information of China (English)

    WEI-WEI LI; HUI LI; ZHI-FEI LIU; QUN QIAO

    2009-01-01

    Objective To determine residual acrylamide in medical polyacrylamide hydrogel by high performance liquid chromatography tandem mass spectroscopy (HPLC-MS). Methods After 13C3 labeled acrylamide was added, the sample was extracted with water and then cleaned up with ExtrelutTM 20. The polyaerylamide hydrogel sample and 20 clinical cases were analyzed by HPLC-MS/MS and isotope dilution quantifying technique in selected reaction monitoring (SRM) mode. Results Acrylamide was separated from polyacrylamide hydrogel. The concentration of acrylamide in polyacrylamide hydrogel ranged from 3.9×109 to 3.1×108g/L in the 20 clinical cases. The peak area was favorable linear and the range was up to 3 000 μg/L. The recovery rate was 103.1% with a relative standard deviation (RSD) of 6.20%, when the mark level was 50 μg/L. Conclusion HPLC-MS is a rapid, accurate, and sensitive method for the determination of residual acrylamide in medical polyacrylamide hydrogel.

  20. Antibiotic toxicity and absorption in zebrafish using liquid chromatography-tandem mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Fan Zhang

    Full Text Available Evaluation of drug toxicity is necessary for drug safety, but in vivo drug absorption is varied; therefore, a rapid, sensitive and reliable method for measuring drugs is needed. Zebrafish are acceptable drug toxicity screening models; we used these animals with a liquid chromatography-tandem mass spectrometry (LC-MS/MS method in a multiple reaction monitoring mode to quantify drug uptake in zebrafish to better estimate drug toxicity. Analytes were recovered from zebrafish homogenate by collecting supernatant. Measurements were confirmed for drugs in the range of 10-1,000 ng/mL. Four antibiotics with different polarities were tested to explore any correlation of drug polarity, absorption, and toxicity. Zebrafish at 3 days post-fertilization (dpf absorbed more drug than those at 6 h post-fertilization (hpf, and different developmental periods appeared to be differentially sensitive to the same compound. By observing abnormal embryos and LD50 values, zebrafish embryos at 6 hpf were considered to be suitable for evaluating embryotoxicity. Also, larvae at 3 dpf were adapted to measure acute drug toxicity in adult mammals. Thus, we can exploit zebrafish to study drug toxicity and can reliably quantify drug uptake with LC-MS/MS. This approach will be helpful for future studies of toxicology in zebrafish.

  1. Identification of Microorganisms by High Resolution Tandem Mass Spectrometry with Accurate Statistical Significance

    Science.gov (United States)

    Alves, Gelio; Wang, Guanghui; Ogurtsov, Aleksey Y.; Drake, Steven K.; Gucek, Marjan; Suffredini, Anthony F.; Sacks, David B.; Yu, Yi-Kuo

    2016-02-01

    Correct and rapid identification of microorganisms is the key to the success of many important applications in health and safety, including, but not limited to, infection treatment, food safety, and biodefense. With the advance of mass spectrometry (MS) technology, the speed of identification can be greatly improved. However, the increasing number of microbes sequenced is challenging correct microbial identification because of the large number of choices present. To properly disentangle candidate microbes, one needs to go beyond apparent morphology or simple `fingerprinting'; to correctly prioritize the candidate microbes, one needs to have accurate statistical significance in microbial identification. We meet these challenges by using peptidome profiles of microbes to better separate them and by designing an analysis method that yields accurate statistical significance. Here, we present an analysis pipeline that uses tandem MS (MS/MS) spectra for microbial identification or classification. We have demonstrated, using MS/MS data of 81 samples, each composed of a single known microorganism, that the proposed pipeline can correctly identify microorganisms at least at the genus and species levels. We have also shown that the proposed pipeline computes accurate statistical significances, i.e., E-values for identified peptides and unified E-values for identified microorganisms. The proposed analysis pipeline has been implemented in MiCId, a freely available software for Microorganism Classification and Identification. MiCId is available for download at http://www.ncbi.nlm.nih.gov/CBBresearch/Yu/downloads.html.

  2. Determination of hexamethylphosphoramide and other highly polar phosphoramides in water samples using reversed-phase liquid chromatography/electrospray ionization time-of-flight mass spectrometry.

    Science.gov (United States)

    Blotevogel, Jens; Borch, Thomas

    2011-09-16

    The widely used solvent hexamethylphosphoramide (HMPA) and its biological (metabolic) and chemical (abiotic) phosphoramide-based oxidation products may cause adverse health effects through occupational exposure and intake of contaminated groundwater. However, no current methods exist for the separation and the detection of the many polar HMPA oxidation products. Thus, we developed a new RPLC/ESI-TOF-MS method and further investigated the chromatographic performances of two columns (i.e., XTerra Phenyl and XBridge Phenyl). In addition, the impact of (forced) acid hydrolysis for optimized chromatographic performance of the XTerra Phenyl column is investigated. The XTerra Phenyl column showed the best separation of the less polar major metabolic oxidation products pentamethylphosphoramide and hydroxymethyl-pentamethylphosphoramide, however, only after treating the column with formic acid (acid-treated). The XTerra column separated most of the investigated HMPA oxidation products (11 of 16 compounds) in a single chromatographic run. In contrast, the XBridge Phenyl column requires one method for the less polar and another method for the more polar oxidation products. However, this results in an overall better separation performance of the XBridge Phenyl column, especially for the less polar major abiotic oxidation products hydroxymethyl-pentamethylphosphoramide and formyl-pentamethylphosphoramide, as well as for 11 highly polar oxidation products (R(S)>1.5). The RPLC/ESI-TOF-MS method presented and validated in this study is the first analytical method that can be used to separate and detect HMPA (LOD 0.10 μM without preconcentration) and all of its oxidation products. PMID:21835414

  3. Pharmacokinetic study of nobiletin and tangeretin in rat serum by high-performance liquid chromatography-electrospray ionization-mass spectrometry

    Science.gov (United States)

    Nobiletin (NOB) and tangeretin (TAN), two of the main polymethoxylated flavones in citrus, influence a number of key biological pathways in mammalian cells. While the impacts of NOB and TAN on glucose homeostasis and cholesterol regulation have been investigated in human clinical trials, much inform...

  4. Metabolomics Analysis of Health Functions of Physalis Pubescens L. using by Ultra-performance Liquid Chromatography/Electrospray Ionization Quadruple Time-of-Flight Mass Spectrometry

    OpenAIRE

    Hang Chu; Hui Sun; Guang-Li Yan; Ai-Hua Zhang; Chang Liu; Hui Dong; Xiang-Cai Meng; Xi-Jun Wang

    2015-01-01

    Herbal medicines may benefit from metabolomics studies, and applying metabolomics may provide answers about which herbal interventions may be effective for individuals, which metabolic processes are triggered, and the subsequent chemical pathways of activity. Physalis pubescens L (PPL) is an herbal fruit for one year living plant and has been developed into healthy function's food. However, the mechanisms of health functions are still unclear. To comprehensively and holistically assess its an...

  5. Dual biosensor immunoassay-directed identification of fluoroquinolones in chicken muscle by liquid chromatography electrospray time-of-flight mass spectrometry

    NARCIS (Netherlands)

    Marchesini, G.R.; Haasnoot, W.; Delahaut, P.; Gercek, H.; Nielen, M.W.F.

    2007-01-01

    Fluoroquinolones (FQs) are synthetic antibiotics of broad-spectrum antibacterial activity widely used to treat infections in farmed fish, turkeys, pigs, calves and poultry. Monitoring these substances residues is therefore regulated by law. For the detection of FQs, we studied the feasibility of cou

  6. Characterization of steroidal saponins from Dioscorea villosa and D Cayennensis using ultrahigh performance liquid chromatography/electrospray ionization quadruple time-of-flight mass spectrometry

    Science.gov (United States)

    Steroidal saponins were reported to be the major physiologically active constituents in yams. The structural characteristics of steroidal saponins in methanolic extracts from dried rhizomes of two Dioscorea species (D. villosa L. and D. cayenensis Lam.) and dietary supplements have analyzed using U...

  7. Elucidation of O-Phosphoryl and N-Phosphoryl Amino Acids by Electrospray Ionization Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    ZHANG,Jian-Chen(张建臣); CAO,Shu-Xiaa(曹书霞); XU,Juna(徐军); LIAO,Xin-Cheng(廖新成); ZHAO,Yu-Fen(赵玉芬)

    2004-01-01

    Mass spectroscopic characteristics of phosphoryl amino acids were studied in detail by positive and negative electrospray ionization mass spectrometry (ESI-MS) in conjunction with tandem mass spectrometry (MS/MS). Besides N-diisopropyloxyphosphoryl amino acids (N-DIPP-AA), O-phospho- and O-diisopropyloxyphosphoryl amino acids (O-DIPP-AA) were studied and compared to N-DIPP-AA. The fragmentation pathways of [M+H]+, [M+Na]+ and [M-H]- ions of phosphoryl amino acids were summarized. In addition to several similar patterns,each of them showed its characteristic fragmention.

  8. An improved method for measuring metaldehyde in surface water using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Schumacher, Melanie; Castle, Glenn; Gravell, Anthony; Mills, Graham A; Fones, Gary R

    2016-01-01

    The molluscicide metaldehyde (2,4,6,8-tetramethyl-1,3,5,7-tetraoxocanemetacetaldehyde) is an emerging pollutant. It is frequently detected in surface waters, often above the European Community Drinking Water Directive limit of 0.1 μg/L for a single pesticide. Gas chromatography mass spectrometry (GC-MS) can be used to determine metaldehyde in environmental waters, but this method requires time consuming extraction techniques prior to instrumental analysis. Use of liquid chromatography-tandem mass spectrometry (LC-MS/MS) can overcome this problem. We describe a novel LC-MS/MS method, using a methylamine mobile phase additive, coupled with on-line sample enrichment that allows for the rapid and sensitive measurement of metaldehyde in surface water. Only the methylamine adduct of metaldehyde was formed with other unwanted alkali metal adducts and dimers being suppressed. As considerably less collision energy is required to fragment the methylamine adduct, a five-fold improvement in method sensitivity, compared to a previous method using an ammonium acetate buffer mobile phase was achieved. This new approach offers: •A validated method that meets regulatory requirements for the determination of metaldehyde in surface water.•Improved reliability of quantification over existing LC-MS/MS methods by using stable precursor ions for multiple reaction monitoring.•Low limits of quantification for tap water (4 ng/L) and river water (20 ng/L) using only 800 μL of sample; recoveries > 97%. PMID:27054094

  9. Measurement of oxidative stress parameters using liquid chromatography-tandem mass spectroscopy (LC-MS/MS)

    International Nuclear Information System (INIS)

    There is increasingly intense scientific and clinical interest in oxidative stress and the many parameters used to quantify the degree of oxidative stress. However, there remain many analytical limitations to currently available assays for oxidative stress markers. Recent improvements in software, hardware, and instrumentation design have made liquid chromatography and tandem mass spectroscopy (LC-MS/MS) methods optimal choices for the determination of many oxidative stress markers. In particular, LC-MS/MS often provides the advantages of higher specificity, higher sensitivity, and the capacity to determine multiple analytes (e.g. 4-11 oxidative stress markers per LC run) when compared to other available methods, such as gas chromatography-MS, immunoassays, spectrophotometric or flourometric assays. LC-MS/MS methods are also compatible with cleanup and sample preparation methods including prior solid phase extraction or automated two dimensional LC/LC chromatography followed by MS/MS. LC-MS/MS provides three analytical filtering functions: (1) the LC column provides initial separation as each analyte elutes from the column. (2) The first MS dimension isolates ions of a particular mass-to-charge (m/z) ratio. (3) The selected precursor ion is fragmented into product ions that provide structural information about the precursor ion. Quantitation is achieved based on the abundances of the product ions. The sensitivity limits for LC-MS/MS usually lie within the range of fg-pg of analyte per LC on-column injection. In this article, the present capabilities of LC-MS/MS are briefly presented and some specific examples of the strengths of these LC-MS/MS assays are discussed. The selected examples include methods for isoprostanes, oxidized proteins and amino acids, and DNA biomarkers of oxidative stress

  10. Greazy: Open-Source Software for Automated Phospholipid Tandem Mass Spectrometry Identification.

    Science.gov (United States)

    Kochen, Michael A; Chambers, Matthew C; Holman, Jay D; Nesvizhskii, Alexey I; Weintraub, Susan T; Belisle, John T; Islam, M Nurul; Griss, Johannes; Tabb, David L

    2016-06-01

    Lipid identification from data produced with high-throughput technologies is essential to the elucidation of the roles played by lipids in cellular function and disease. Software tools for identifying lipids from tandem mass (MS/MS) spectra have been developed, but they are often costly or lack the sophistication of their proteomics counterparts. We have developed Greazy, an open source tool for the automated identification of phospholipids from MS/MS spectra, that utilizes methods similar to those developed for proteomics. From user-supplied parameters, Greazy builds a phospholipid search space and associated theoretical MS/MS spectra. Experimental spectra are scored against search space lipids with similar precursor masses using a peak score based on the hypergeometric distribution and an intensity score utilizing the percentage of total ion intensity residing in matching peaks. The LipidLama component filters the results via mixture modeling and density estimation. We assess Greazy's performance against the NIST 2014 metabolomics library, observing high accuracy in a search of multiple lipid classes. We compare Greazy/LipidLama against the commercial lipid identification software LipidSearch and show that the two platforms differ considerably in the sets of identified spectra while showing good agreement on those spectra identified by both. Lastly, we demonstrate the utility of Greazy/LipidLama with different instruments. We searched data from replicates of alveolar type 2 epithelial cells obtained with an Orbitrap and from human serum replicates generated on a quadrupole-time-of-flight (Q-TOF). These findings substantiate the application of proteomics derived methods to the identification of lipids. The software is available from the ProteoWizard repository: http://tiny.cc/bumbershoot-vc12-bin64 . PMID:27186799

  11. Accelerator mass spectrometry of the heaviest long-lived radionuclides with a 3-MV tandem accelerator

    Indian Academy of Sciences (India)

    Christof Vockenhuber; Robin Golser; Walter Kutschera; Alfred Priller; Peter Steier; Stephan Winkler; Vitaly Liechtenstein

    2002-12-01

    A 3-MV pelletron tandem accelerator is the heart of the Vienna environmental research accelerator (VERA). The original design of the beam transport components allows the transport of ions of all elements, from the lightest to the heaviest. For light ions the suppression of neighboring masses was sufficient to measure isotopic ratios of 14C/12C and 26Al/27Al as low as 10-15 and 10Be/9Be down to 10-13. To suppress neighboring masses for the heaviest radionuclides in the energy range of 10–20 MeV, the resolution of VERA was increased both by improving the ion optics of existing elements at the injection side and by installing a new high-resolution electrostatic separator at the high-energy side. Interfering ions which pass all beam filters are identified with a Bragg-type ionization detector and a high-resolution time-of-flight system. Two ultra-thin diamond-like carbon (DLC) foils are used in the start and stop detector, which substantially reduces losses due to beam straggling. This improved set up enables us to measure even the heaviest long-lived radionuclides, where stable isobaric interferences are absent (e.g. 236U and 244Pu), down to environmental levels. Moreover, the advantage of a ‘small’ and well manageable machine like VERA lies in its higher stability and reliability which allows to measure these heavy radionuclides more accurately, and also a large number of samples.

  12. Determination of bedaquiline in human serum using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Alffenaar, Jan-Willem C; Bolhuis, Mathieu; van Hateren, Kai; Sturkenboom, Marieke; Akkerman, Onno; de Lange, Wiel; Greijdanus, Ben; van der Werf, Tjip; Touw, Daan

    2015-09-01

    Bedaquiline, a diarylquinoline for the treatment of multidrug-resistant tuberculosis (TB), relies on exposure-dependent killing. As data on drug exposure in specific populations are scarce, pharmacokinetic studies may be of interest. No simple and robust validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been reported to date. Therefore, a new method using a quadrupole mass spectrometer was developed for analysis of bedaquiline and N-monodesmethyl bedaquiline (M2) in human serum, using deuterated bedaquiline as the internal standard. The calibration curve was linear over a range of 0.05 (lower limit of quantification [LLOQ]) to 6.00 mg/liter for both bedaquiline and M2, with correlation coefficient values of 0.997 and 0.999, respectively. The calculated accuracy ranged from 1.9% to 13.6% for bedaquiline and 2.9% to 8.5% for M2. Within-run precision ranged from 3.0% to 7.2% for bedaquiline and 3.1% to 5.2% for M2, and between-run precision ranged from 0.0% to 4.3% for bedaquiline and 0.0% to 4.6% for M2. Evaluation of serum concentrations in a patient receiving bedaquiline showed high levels at the end of treatment, reflecting accumulation of the drug. More observational pharmacokinetic data are needed to relate altered drug concentrations to clinical outcome or adverse drug effects. A simple LC-MS/MS method to quantify bedaquiline and M2 levels in human serum using a deuterated internal standard has been validated. This method can be used in clinical studies and daily practice. PMID:26149993

  13. Neutron-encoded signatures enable product ion annotation from tandem mass spectra.

    Science.gov (United States)

    Richards, Alicia L; Vincent, Catherine E; Guthals, Adrian; Rose, Christopher M; Westphall, Michael S; Bandeira, Nuno; Coon, Joshua J

    2013-12-01

    We report the use of neutron-encoded (NeuCode) stable isotope labeling of amino acids in cell culture for the purpose of C-terminal product ion annotation. Two NeuCode labeling isotopologues of lysine, (13)C6(15)N2 and (2)H8, which differ by 36 mDa, were metabolically embedded in a sample proteome, and the resultant labeled proteins were combined, digested, and analyzed via liquid chromatography and mass spectrometry. With MS/MS scan resolving powers of ~50,000 or higher, product ions containing the C terminus (i.e. lysine) appear as a doublet spaced by exactly 36 mDa, whereas N-terminal fragments exist as a single m/z peak. Through theory and experiment, we demonstrate that over 90% of all y-type product ions have detectable doublets. We report on an algorithm that can extract these neutron signatures with high sensitivity and specificity. In other words, of 15,503 y-type product ion peaks, the y-type ion identification algorithm correctly identified 14,552 (93.2%) based on detection of the NeuCode doublet; 6.8% were misclassified (i.e. other ion types that were assigned as y-type products). Searching NeuCode labeled yeast with PepNovo(+) resulted in a 34% increase in correct de novo identifications relative to searching through MS/MS only. We use this tool to simplify spectra prior to database searching, to sort unmatched tandem mass spectra for spectral richness, for correlation of co-fragmented ions to their parent precursor, and for de novo sequence identification. PMID:24043425

  14. Neutron-encoded Signatures Enable Product Ion Annotation From Tandem Mass Spectra*

    Science.gov (United States)

    Richards, Alicia L.; Vincent, Catherine E.; Guthals, Adrian; Rose, Christopher M.; Westphall, Michael S.; Bandeira, Nuno; Coon, Joshua J.

    2013-01-01

    We report the use of neutron-encoded (NeuCode) stable isotope labeling of amino acids in cell culture for the purpose of C-terminal product ion annotation. Two NeuCode labeling isotopologues of lysine, 13C615N2 and 2H8, which differ by 36 mDa, were metabolically embedded in a sample proteome, and the resultant labeled proteins were combined, digested, and analyzed via liquid chromatography and mass spectrometry. With MS/MS scan resolving powers of ∼50,000 or higher, product ions containing the C terminus (i.e. lysine) appear as a doublet spaced by exactly 36 mDa, whereas N-terminal fragments exist as a single m/z peak. Through theory and experiment, we demonstrate that over 90% of all y-type product ions have detectable doublets. We report on an algorithm that can extract these neutron signatures with high sensitivity and specificity. In other words, of 15,503 y-type product ion peaks, the y-type ion identification algorithm correctly identified 14,552 (93.2%) based on detection of the NeuCode doublet; 6.8% were misclassified (i.e. other ion types that were assigned as y-type products). Searching NeuCode labeled yeast with PepNovo+ resulted in a 34% increase in correct de novo identifications relative to searching through MS/MS only. We use this tool to simplify spectra prior to database searching, to sort unmatched tandem mass spectra for spectral richness, for correlation of co-fragmented ions to their parent precursor, and for de novo sequence identification. PMID:24043425

  15. [Determination of aflatoxins in cereals and oils by liquid chromatography-triple quadrupole tandem mass spectrometry].

    Science.gov (United States)

    Wang, Xiupin; Li, Peiwu; Yang, Yang; Zhang, Wen; Zhang, Qi; Fan, Sufang; Yu, Li; Wang, Lin; Chen, Xiaomei; Li, Ying; Jiang, Jun

    2011-06-01

    The high performance liquid chromatography (HPLC)-triple quadrupole tandem mass spectrometry was applied for the determination of the aflatoxins: B1 (AFB1), B2 (AFB2), G1 (AFG1) and G2 (AFG2), in cereals and oils. The samples were first extracted by ultrasonic method. The optimized conditions of ultrasonic extraction were as follows: temperature of 50 degrees C, extraction time of 3 min, methanol-water (containing 40 g/L NaCl) (80: 20, v/v) solution as the medium and a ratio of sample to solvent of 1 : 3 (g: mL). The extracts were then purified using an immunoaffinity column. The separation was performed on a C18 column with mobile phases of 10 mmol/L ammonium acetate and methanol in gradient elution. The sensitive detection of the four AFT compounds by electrospray ionization mass spectrometry (ESI-MS) was carried out in selected reaction monitoring (SRM) mode with aflatoxin M1 (AFM1) as the internal standard. Under the optimized conditions, the limits of detection of AFB1, AFB2, AFG1 and AFG2 were 0.002, 0.004, 0.004 and 0.012 microg/kg, respectively. The recoveries of aflatoxins in different spiked cereals and oils were in the range from 87% to 111%. The intra-day and inter-day precisions were not more than 6.7% and 5.6%, respectively. In comparison with the external standard method, this method can effectively inhibit the matrix effects, and greatly improve the accuracy. PMID:22032163

  16. Automated processing of whole blood samples for the determination of immunosuppressants by liquid chromatography tandem-mass spectrometry

    OpenAIRE

    Vogeser, Michael; Spöhrer, Ute

    2006-01-01

    Background: Liquid chromatography tandem-mass spectrometry (LC-MS/MS) is an efficient technology for routine determination of immunosuppressants in whole blood; however, time-consuming manual sample preparation remains a significant limitation of this technique. Methods: Using a commercially available robotic pipetting system (Tecan Freedom EVO), we developed an automated sample-preparation protocol for quantification of tacrolimus in whole blood by LC-MS/MS. Barcode reading, sample resuspens...

  17. Quantitative analysis of adenosine using Liquid Chromatography/Atmospheric Pressure Chemical Ionization - tandem Mass Spectrometry (LC/APCI-MS/MS)

    OpenAIRE

    Van Dycke, Annelies; Verstraete, Alain; Pil, Kristof; Raedt, Robrecht; Vonck, Kristl; Boison, Detlev; Boon, Paul

    2010-01-01

    Adenosine-secreting cellular brain implants constitute a promising therapeutic approach for the treatment of epilepsy. To engineer neural stem cells for therapeutic adenosine delivery, a reliable and fast analytical method is necessary to quantify cell-based adenosine release. Here we describe the development, optimization and validation of adenosine measurement using liquid chromatography – atmospheric pressure chemical ionization – tandem mass spectrometry (LC-APCI-MS/MS). LC-MS/MS in posit...

  18. Analysis of Androgenic Steroids in Environmental Waters by Large-volume Injection Liquid Chromatography Tandem Mass Spectrometry

    OpenAIRE

    Backe, Will J.; Ort, Christoph; Brewer, Alex J.; Field, Jennifer A.

    2011-01-01

    A new method was developed for the analysis of natural and synthetic androgenic steroids and their selected metabolites in aquatic environmental matrices using direct large-volume injection (LVI) high performance liquid chromatography (HPLC) tandem mass spectrometry (MS/MS). Method accuracy ranged from 88 to 108% for analytes with well-matched internal standards. Precision, quantified by relative standard deviation (RSD), was less than 12%. Detection limits for the method ranged from 1.2 to 3...

  19. A high-resolution tandem mass spectrometer for the collision-induced dissociation of large molecule ions

    International Nuclear Information System (INIS)

    Instrumental development in the field of tandem mass spectrometry is described in order to use the technique for the analysis of large organic molecules. Experiments are also described in which the process of collision-induced dissociation (CID) is investigated. The fragmentation pattern of CH4+ has been measured for three different target gases He, Ar and Xe. From these measurements fragmentation cross sections are calculated. 192 refs.; 47 figs.; 6 tabs

  20. Simultaneous Determination of 25 Common Pharmaceuticals in Whole Blood Using Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Marie Katrine Klose; Johansen, Sys Stybe

    2012-01-01

    An ultra-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of 25 common pharmaceuticals in whole blood. The selected pharmaceuticals represent the most frequently detected drugs in our forensic laboratory with basic properties suc...... analytes. Only unstable compounds like levomepromazine, methylphenidate, mirtazapine, norfluoxetine and zuclopenthixol deviated more. The method was successfully applied to more than 200 authentic blood samples within a year from forensic investigations....

  1. Detection of Carbapenemase-Producing Bacteria by Using an Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry Method

    OpenAIRE

    Carricajo, Anne; Verhoeven, Paul O.; Guezzou, Salim; Fonsale, Nathalie; Aubert, Gerald

    2014-01-01

    The emergence of carbapenemase-producing bacteria poses a new challenge in the management of antibiotic therapies for patients. This report describes a new method using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for rapid detection of carbapenemase activity in enterobacteria, Pseudomonas aeruginosa, and Acinetobacter baumannii. In a panel of 78 isolates, including 41 carbapenemase-producing strains, the ULPC-MS/MS assay showed 100% agreement with molecular c...

  2. Paclobutrazol Residue Determination in Potato and Soil Using Low Temperature Partition Extraction and Ultrahigh Performance Liquid Chromatography Tandem Mass Spectrometry

    OpenAIRE

    Hongcheng Liu; Tao Lin; Jia Mao; Huan Lu; Dongshun Yang; Jiliang Wang; Qiwan Li

    2015-01-01

    A simple, accurate, and highly sensitive analytical method was developed for determining the paclobutrazol residue in potato and soil, the dynamics dissipation in soil. Extraction was carried out by low temperature partitioning and analyzed by ultrahigh performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). For a favor extraction yield, the parameters such as temperature and solvent were optimized. The result showed that sample would be easily frozen and separated using ace...

  3. Simultaneous determination of 14 β-lactam antibiotics in cosmetic products by liquid chromatography tandem mass spectrometry method

    Institute of Scientific and Technical Information of China (English)

    Cai Sheng Wu; Jin Lan Zhang; Yan Ling Qiao; Yi Lin Wang; Zhi Rong Chen

    2011-01-01

    In this study, a simple and rapid high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was established and validated to determine the 14 β-lactam antibiotics in cosmetic products, including 1 (ceftazidime), 2 (cefaclor), 3 (cefdinir), 4 (ampicillin), 5 (cefalexin), 6 (ceftezole), 7 (cefotaxim), 8 (cefradine), 9 (cefuroxime), 10 (cephazoline), 11 (cefathiamidine), 12 (cefoperazone), 13 (cafalotin), 14 (piperacillin).

  4. High performance liquid chromatography-tandem mass spectrometry of pharmaceuticals and personal care products in environmental and biological matrices

    OpenAIRE

    Purcell, Martha

    2009-01-01

    Pharmaceuticals and personal care products (PPCPs) have emerged in recent years as a new class of chemical and biological pollutants in our environment. In the search for suitably sensitive and specific techniques for detection of these compounds at very low concentrations, liquid chromatography-tandem mass spectrometry (LCMS/ MS) has emerged as the new technique of choice. This work describes methods for screening and quantification of various pharmaceutical and illicit drug residues i...

  5. Simultaneous analysis of buprenorphine, methadone, cocaine, opiates and nicotine metabolites in sweat by liquid chromatography tandem mass spectrometry

    OpenAIRE

    Concheiro, Marta; Shakleya, Diaa M.; Huestis, Marilyn A.

    2010-01-01

    A liquid chromatography tandem mass spectrometry method for buprenorphine (BUP), norbuprenorphine (NBUP), methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), cocaine, benzoylecgonine, ecgonine methyl ester (EME), morphine, codeine, 6-acetylmorphine, heroin, 6-acetylcodeine, cotinine, and trans-3′-hydroxycotinine quantification in sweat was developed and comprehensively validated. Sweat patches were mixed with 6 mL acetate buffer at pH 4.5, and supernatant extracted with Strat...

  6. Liquid chromatography with tandem mass spectrometry-based proteomic discovery in aging and Alzheimer’s disease

    OpenAIRE

    Montine, Thomas J.; Woltjer, Randall L.; Pan, Catherine; Montine, Kathleen S.; Zhang, Jing

    2006-01-01

    Systems biology offers enormous potential to understand the complexity of human brain aging and neurodegenerative diseases. Proteomics has an important role in these investigations because of its unique strengths and because of the potential central pathogenic contribution of pathological protein to several of these diseases. Here we have reviewed the methods and presented some examples of liquid chromatography—electrospray ionization—tandem mass spectrometry— based proteomics, with and witho...

  7. Simultaneous determination of four designer drugs and their major metabolites by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Chen, Xueguo

    2015-06-15

    A sensitive liquid chromatography-electrospray ionization-ion trap mass spectrometry (LC-ESI-ITMS) method was utilized for the simultaneous analysis of four designer drugs and their in vitro metabolites in rat liver microsome S9 fraction. Four designer drugs, including methcathinone (MC), 3,4-methylenedioxymethcathinone (MDMC), 3,4-methylenedioxy-pyrovalerone (MDPV) and 4'-methyl-α-pyrrolidinopropiophenone (MPPP), were individually incubated with rat liver microsome S9 fraction, and the incubation mixtures were pooled together and analyzed by LC-ESI-ITMS simultaneously. Besides four designer drugs, five of their main metabolites were identified via the analysis of protonated molecules and tandem mass spectrometry data. Meanwhile, the quantification analysis of four designer drugs in rat liver microsome S9 fraction was performed, the calibration curves showed good linearity in the range of 0.01-5.0μg/mL and the detection limits were below 0.03μg/mL with RSDs less than 5.9% and recovery ratios above 77.4%. The experimental results not only showed that these designer drugs could be easily metabolized in rat liver microsome, and also displayed the superiorities of the method including time and cost saving, high efficiency, sensitivity and selectivity. The studies in this study indicated that the approach could be applied in the determination of illicit drugs and their metabolites in medical, pharmaceutical and forensic investigations. PMID:25939091

  8. A supercritical fluid chromatography/tandem mass spectrometry method for the simultaneous quantification of metformin and gliclazide in human plasma

    Directory of Open Access Journals (Sweden)

    Agrawal Y

    2010-01-01

    Full Text Available Present study reports the development and validation of a simultaneous estimation of metformin and gliclazide in human plasma using supercritical fluid chromatography followed by tandem mass spectrometry. Acetonitrile:water (80:20 mixture was used as a mobile phase along with liquid CO 2 in supercritical fluid chromatography and phenformin as an internal standard. The modified plasma samples were analyzed by electro-spray ionization method in selective reaction monitoring mode in tandem mass spectrometry. Supercritical fluid chromatographic separation was performed using nucleosil C 18 containing column as a stationary phase. The separated products were identified by characteristic peaks and specific fragments peaks in tandem mass spectrometry as m/z 130 to 86 for metformin, m/z 324 to 110 for gliclazide and m/z 206 to 105 for phenformin. The present method was found linear in the concentration ranges of 6.0-3550 ng/ml and 7.5-7500 ng/ml for metformin and gliclazide, respectively. Pharmacokinetic study was performed after an oral administration of dispersible tablets containing 500 mg of metformin and 80 mg of gliclazide using same techniques.

  9. Binomial probability distribution model-based protein identification algorithm for tandem mass spectrometry utilizing peak intensity information.

    Science.gov (United States)

    Xiao, Chuan-Le; Chen, Xiao-Zhou; Du, Yang-Li; Sun, Xuesong; Zhang, Gong; He, Qing-Yu

    2013-01-01

    Mass spectrometry has become one of the most important technologies in proteomic analysis. Tandem mass spectrometry (LC-MS/MS) is a major tool for the analysis of peptide mixtures from protein samples. The key step of MS data processing is the identification of peptides from experimental spectra by searching public sequence databases. Although a number of algorithms to identify peptides from MS/MS data have been already proposed, e.g. Sequest, OMSSA, X!Tandem, Mascot, etc., they are mainly based on statistical models considering only peak-matches between experimental and theoretical spectra, but not peak intensity information. Moreover, different algorithms gave different results from the same MS data, implying their probable incompleteness and questionable reproducibility. We developed a novel peptide identification algorithm, ProVerB, based on a binomial probability distribution model of protein tandem mass spectrometry combined with a new scoring function, making full use of peak intensity information and, thus, enhancing the ability of identification. Compared with Mascot, Sequest, and SQID, ProVerB identified significantly more peptides from LC-MS/MS data sets than the current algorithms at 1% False Discovery Rate (FDR) and provided more confident peptide identifications. ProVerB is also compatible with various platforms and experimental data sets, showing its robustness and versatility. The open-source program ProVerB is available at http://bioinformatics.jnu.edu.cn/software/proverb/ . PMID:23163785

  10. Optimization of a liquid chromatography-tandem mass spectrometry method for quantification of the plant lignans secoisolariciresinol, matairesinol, lariciresinol and pinoresinol in foods

    NARCIS (Netherlands)

    Milder, I.E.J.; Arts, I.C.W.; Venema, D.P.; Lasaroms, J.J.P.; Wähälä, K.; Hollman, P.C.H.

    2004-01-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the quantification of the four major enterolignan precursors [secoisolariciresinol, matairesinol, lariciresinol, and pinoresinol] in foods. The method consists of alkaline methanolic extraction, followed by enzymati

  11. Comprehensive analysis of the mouse renal cortex using two-dimensional HPLC – tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Denner Larry

    2008-05-01

    Full Text Available Abstract Background Proteomic methodologies increasingly have been applied to the kidney to map the renal cortical proteome and to identify global changes in renal proteins induced by diseases such as diabetes. While progress has been made in establishing a renal cortical proteome using 1-D or 2-DE and mass spectrometry, the number of proteins definitively identified by mass spectrometry has remained surprisingly small. Low coverage of the renal cortical proteome as well as our interest in diabetes-induced changes in proteins found in the renal cortex prompted us to perform an in-depth proteomic analysis of mouse renal cortical tissue. Results We report a large scale analysis of mouse renal cortical proteome using SCX prefractionation strategy combined with HPLC – tandem mass spectrometry. High-confidence identification of ~2,000 proteins, including cytoplasmic, nuclear, plasma membrane, extracellular and unknown/unclassified proteins, was obtained by separating tryptic peptides of renal cortical proteins into 60 fractions by SCX prior to LC-MS/MS. The identified proteins represented the renal cortical proteome with no discernible bias due to protein physicochemical properties, subcellular distribution, biological processes, or molecular function. The highest ranked molecular functions were characteristic of tubular epithelium, and included binding, catalytic activity, transporter activity, structural molecule activity, and carrier activity. Comparison of this renal cortical proteome with published human urinary proteomes demonstrated enrichment of renal extracellular, plasma membrane, and lysosomal proteins in the urine, with a lack of intracellular proteins. Comparison of the most abundant proteins based on normalized spectral abundance factor (NSAF in this dataset versus a published glomerular proteome indicated enrichment of mitochondrial proteins in the former and cytoskeletal proteins in the latter. Conclusion A whole tissue extract of

  12. Quantitative selenium speciation in human urine by using liquid chromatography–electrospray tandem mass spectrometry

    International Nuclear Information System (INIS)

    Highlights: ► Development of a selected reaction monitoring mass spectrometric method for the identification of Se species in human urine. ► A selenosugar was detected as the major human urinary metabolite of selenium in the samples analysed. ► The trimethylselenonium ion was detected in the urine of one volunteer before and after receiving a selenium supplement. ► Strict quality control measures were applied to validate identification. ► Quantitation was conducted using an isotopically labelled internal standard and the standard additions methodology. - Abstract: A liquid chromatography–electrospray-tandem mass spectrometry (ES-MS/MS) method was developed for the speciation analysis of four organic selenium species of relevance to human urinary metabolism, namely trimethylselenomium ion (TMSe+), selenomethionine (SeMet) and the two selenosugars, methyl 2-acetamido-2-deoxy-1-seleno-β-D-galactos/-glucos-amine (SeGalNAc and SeGluNAc, respectively). Their chromatographic separation was achieved by using a cation exchange pre-column coupled in-series with a reversed-phase high-performance liquid chromatography column, along with an isocratic mobile phase. Online detection was performed using ES-MS/MS in selective reaction monitoring mode. SeGalNAc was detected as the major human urinary metabolite of selenium in the samples analysed, whereas TMSe+ was detected in the urine of one volunteer before and after receiving a selenium supplement. SeMet was not detected as a urine excretory metabolite in this study. Spiking experiments performed with the urine samples revealed significant signal suppression caused by coeluting matrix constituents. To overcome such interferences, isotopically labelled 13CD382SeGalNAc was used as an internal standard, whereas in the absence of an isotopically labelled internal standard for TMSe+, the standard addition method was applied. Quality control for the accurate quantitation of TMSe+ and SeGalNAc was carried out by analysing

  13. Detection of 36 antibiotics in coastal waters using high performance liquid chromatography-tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    NA Guangshui; GU Jia; GE Linke; ZHANG Peng; WANG Zhen; LIU Chunyang; ZHANG Lin

    2011-01-01

    Among pharmaceuticals and personal care products released into the aquatic environment,antibiotics are of particular concern,because of their ubiquity and health effects.Although scientists have recently paid more attention to the threat of antibiotics to coastal ecosystems,researchers have often focused on relatively few antibiotics,because of the absence of suitable analytical methods.We have therefore developed a method for the rapid detection of 36 antibiotic residues in coastal waters,including tetracyclines (TCs),sulfanilamides (SAs),and quinolones (QLs).The method consists of solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis,using electrospray ionization (ESI) in positive mode.The SPE was performed with Oasis HLB and Oasis MCX cartridges.Chromatographic separation on a C18 column was achieved using a binary eluent containing methanol and water with 0.1% formic acid.Typical recoveries of the analytes ranged from 67.4% to 109.3% at a fortification level of 100 ng/L.The precision of the method,calculated as relative standard deviation (RSD),was below 14.6% for all the compounds.The limits of detection (LODs) varied from 0.45 pg to 7.97 pg.The method was applied to determine the target analytes in coastal waters of the Yellow Sea in Liaoning,China.Among the tested antibiotics,31 were found in coastal waters,with their concentrations between the LOD and 212.5 ng/L.These data indicate that this method is valid for analysis of antibiotics in coastal waters.The study first reports such a large number of antibiotics along the Yellow Sea coast of Liaoning,and should facilitate future comprehensive evaluation of antibiotics in coastal ecosystems.

  14. Simultaneous quantification of multiple urinary naphthalene metabolites by liquid chromatography tandem mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Daniel C Ayala

    Full Text Available Naphthalene is an environmental toxicant to which humans are exposed. Naphthalene causes dose-dependent cytotoxicity to murine airway epithelial cells but a link between exposure and human pulmonary disease has not been established. Naphthalene toxicity in rodents depends on P450 metabolism. Subsequent biotransformation results in urinary elimination of several conjugated metabolites. Glucuronide and sulfate conjugates of naphthols have been used as markers of naphthalene exposure but, as the current studies demonstrate, these assays provide a limited view of the range of metabolites generated from the parent hydrocarbon. Here, we present a liquid chromatography tandem mass spectrometry method for measurement of the glucuronide and sulfate conjugates of 1-naphthol as well as the mercapturic acids and N-acetyl glutathione conjugates from naphthalene epoxide. Standard curves were linear over 2 log orders. On column detection limits varied from 0.91 to 3.4 ng; limits of quantitation from 1.8 to 6.4 ng. The accuracy of measurement of spiked urine standards was -13.1 to + 5.2% of target and intra-day and inter-day variability averaged 7.2 (± 4.5 and 6.8 (± 5.0 %, respectively. Application of the method to urine collected from mice exposed to naphthalene at 15 ppm (4 hrs showed that glutathione-derived metabolites accounted for 60-70% of the total measured metabolites and sulfate and glucuronide conjugates were eliminated in equal amounts. The method is robust and directly measures several major naphthalene metabolites including those derived from glutathione conjugation of naphthalene epoxide. The assays do not require enzymatic deconjugation, extraction or derivatization thus simplifying sample work up.

  15. Determination of tetracycline residues in soil by pressurized liquid extraction and liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Andreu, Vicente; Vazquez-Roig, Pablo; Blasco, Cristina; Picó, Yolanda

    2009-07-01

    An optimized extraction and cleanup method for the analysis of chlortetracycline (CTC), doxycycline (DC), oxytetracycline (OTC) and tetracycline (TC) in soil is presented. Soil extraction in a pressurized liquid extraction system, followed by extract clean up using solid-phase extraction (SPE) and tetracycline determination by liquid chromatography tandem mass spectrometry (LC-MS/MS) provided appropriate efficiency and reproducibility. Different dispersing agents and solvents for soil extraction and several SPE cartridges for cleanup were compared. The best extraction results were obtained using ethylenediamine tetraacetic acid-treated sand as dispersing agent, and water at 70 degrees C. The most effective cleanup was obtained using Strata-X sorbent in combination with a strong anion exchange cartridge. Recoveries ranged from 71% to 96% and precision, as indicated by the relative standard deviations, was within the range of 8-15%. The limits of quantification (LOQs) by using LC-MS/MS, based on signal-to-noise ratio (S/N) of 10, ranged from 1 microg kg(-1) for TC to 5 microg kg(-1) for CTC. These results pointed out that this technique is appropriate to determine tetracyclines in soils. Analysis of 100 samples taken in the Valencian Community revealed that, in soil, up to 5 microg kg(-1) CTC, 15 microg kg(-1) OTC, 18 microg kg(-1) TC, and 12 microg kg(-1) DC could be detected. Detection of the analytes in several samples, which typify great part of the Spanish agricultural soils, should be outlined as most important result of this study. PMID:19205670

  16. Determination of pharmaceuticals in biosolids using accelerated solvent extraction and liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Ding, Yunjie; Zhang, Weihao; Gu, Cheng; Xagoraraki, Irene; Li, Hui

    2011-01-01

    An analytical method was developed to quantitatively determine pharmaceuticals in biosolid (treated sewage sludge) from wastewater treatment plants (WWTPs). The collected biosolid samples were initially freeze dried, and grounded to obtain relatively homogenized powders. Pharmaceuticals were extracted using accelerated solvent extraction (ASE) under the optimized conditions. The optimal operation parameters, including extraction solvent, temperature, pressure, extraction time and cycles, were identified to be acetonitrile/water mixture (v/v 7:3) as extraction solvent with 3 extraction cycles (15 min for each cycle) at 100 °C and 100 bars. The extracts were cleaned up using solid-phase extraction followed by determination by liquid chromatography coupled with tandem mass spectrometry. For the 15 target pharmaceuticals commonly found in the environment, the overall method recoveries ranged from 49% to 68% for tetracyclines, 64% to 95% for sulfonamides, and 77% to 88% for other pharmaceuticals (i.e. acetaminophen, caffeine, carbamazepine, erythromycin, lincomycin and tylosin). The developed method was successfully validated and applied to the biosolid samples collected from WWTPs located in six cities in Michigan. Among the 15 target pharmaceuticals, 14 pharmaceuticals were detected in the collected biosolid samples. The average concentrations ranged from 2.6 μg/kg for lincomycin to 743.6 μg/kg for oxytetracycline. These results indicated that pharmaceuticals could survive wastewater treatment processes, and accumulate in sewage sludge and biosolids. Subsequent land application of the contaminated biosolids could lead to the dissemination of pharmaceuticals in soil and water environment, which poses potential threats to at-risk populations in the receiving ecosystems. PMID:21112593

  17. Quantification and pharmacokinetics of crizotinib in rats by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Qiu, Feng; Gu, Yanan; Wang, Tingting; Gao, Yingying; Li, Xiao; Gao, Xiangyu; Cheng, Shan

    2016-06-01

    Crizotinib is a small molecule inhibitor of anaplastic lymphoma kinase (ALK) and can be used to treat ALK-positive nonsmall-cell lung cancer. A rapid and simple high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of crizotinib in rat plasma using a chemical synthetic compound buspirone as the internal standard (IS). The plasma samples were pretreated by a simple protein precipitation with methanol-acetonitrile (1:1, v/v). Chromatographic separation was successfully achieved on an Agilent Zorbax XDB C18 column (2.1 × 50 mm, 3.5 µm). The gradient elution system was composed of 0.1% formic acid aqueous solution and 0.1% formic acid in methanol solution. The flow rate was set at 0.50 mL/min. The multiple reaction monitoring was based on the transitions of m/z = 450.3 → 177.1 for crizotinib and 386.2 → 122.2 for buspirone (IS). The assay was successfully validated to demonstrate the selectivity, matrix effect, linearity, lower limit of quantification, accuracy, precision, recovery and stability according to the international guidelines. The lower limit of quantification was 1.00 ng/mL in 50 μL of rat plasma. This LC-MS/MS assay was successfully applied to the quantification and pharmacokinetic study of crizotinib in rats after intravenous and oral administration of crizotinib. The oral absolute bioavailability of crizotinib in rats was 68.6 ± 9.63%. Copyright © 2015 John Wiley & Sons, Ltd. PMID:26467669

  18. Determination of spinetoram in leafy vegetable crops using liquid chromatography and confirmation via tandem mass spectrometry.

    Science.gov (United States)

    Liu, Xue; Abd El-Aty, A M; Park, Ji-Yeon; Park, Jong-Hyouk; Cho, Soon-Kil; Shin, Ho-Chul; Shim, Jae-Han

    2011-10-01

    Spinetoram is a second-generation member of the spinosyn class, all members of which have been shown to be effective in insect control via a novel mode of action. Spinetoram is a mixture of 3'-O-ethyl-5, 6-dihydro spinosyn J (XDE-175-J) and 3'-O-ethyl spinosyn L (XDE-175-L). In order to establish a determination method for the analysis of spinetoram residues in crops, commercial product (5% suspension concentrate spinetoram) was applied to two leafy vegetables (Garland chrysanthemum and Aster scaber) on different spraying schedules. The analytical method used herein was based on a reversed-phase separation on a C(18) column, isocratic elution and UV detection. The analytes were confirmed via tandem mass spectrometry. The method was linear over a concentration range of 0.05-10 ppm with a correlation coefficient in excess of 0.9998. The recoveries of XDE-175-J and XDE-175-L from the two vegetables ranged between 86.04 and 98.87% at spiking levels of 1 and 5 ppm. The relative standard deviations were no more than 7% for all recovery tests conducted herein. The calculated limits of detection and quantification were 0.01 and 0.03 ppm for both XDE-175-J and XDE-175-L. The levels of residues in two vegetables treated under a fixed schedule in the greenhouse were 6.21-0.55 ppm (maximum residue limit (MRL) = 7 ppm). In sum, this method constitutes an easy and reliable technique for the determination of spinetoram in leafy vegetables. PMID:21287582

  19. Nitroproteins in Human Astrocytomas Discovered by Gel Electrophoresis and Tandem Mass Spectrometry

    Science.gov (United States)

    Peng, Fang; Li, Jianglin; Guo, Tianyao; Yang, Haiyan; Li, Maoyu; Sang, Shushan; Li, Xuejun; Desiderio, Dominic M.; Zhan, Xianquan

    2015-12-01

    Protein tyrosine nitration is involved in the pathogenesis of highly fatal astrocytomas, a type of brain cancer. To understand the molecular mechanisms of astrocytomas and to discover new biomarkers/therapeutic targets, we sought to identify nitroproteins in human astrocytoma tissue. Anti-nitrotyrosine immunoreaction-positive proteins from a high-grade astrocytoma tissue were detected with two-dimensional gel electrophoresis (2DGE)-based nitrotyrosine immunoblots, and identified with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Fifty-seven nitrotyrosine immunopositive protein spots were detected. A total of 870 proteins (nitrated and non-nitrated) in nitrotyrosine-immunopositive 2D gel spots were identified, and 18 nitroproteins and their 20 nitrotyrosine sites were identified with MS/MS analysis. These nitroproteins participate in multiple processes, including drug-resistance, signal transduction, cytoskeleton, transcription and translation, cell proliferation and apoptosis, immune response, phenotypic dedifferentiation, cell migration, and metastasis. Among those nitroproteins that might play a role in astrocytomas was nitro-sorcin, which is involved in drug resistance and metastasis and might play a role in the spread and treatment of an astrocytoma. Semiquantitative immune-based measurements of different sorcin expressions were found among different grades of astrocytomas relative to controls, and a semiquantitative increased nitration level in high-grade astrocytoma relative to control. Nitro-β-tubulin functions in cytoskeleton and cell migration. Semiquantitative immunoreactivity of β-tubulin showed increased expression among different grades of astrocytomas relative to controls and semiquantitatively increased nitration level in high-grade astrocytoma relative to control. Each nitroprotein was rationalized and related to the corresponding functional system to provide new insights into tyrosine nitration and its potential role in the

  20. Simultaneous quantification of Pacific ciguatoxins in fish blood using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Mak, Yim Ling; Wu, Jia Jun; Chan, Wing Hei; Murphy, Margaret B; Lam, James C W; Chan, Leo L; Lam, Paul K S

    2013-04-01

    Ciguatera fish poisoning (CFP) is a food intoxication caused by exposure to ciguatoxins (CTXs) in coral reef fish. Rapid analytical methods have been developed recently to quantify Pacific-CTX-1 (P-CTX-1) in fish muscle, but it is destructive and can cause harm to valuable live coral reef fish. Also fish muscle extract was complex making CTX quantification challenging. Not only P-CTX-1, but also P-CTX-2 and P-CTX-3 could be present in fish, contributing to ciguatoxicity. Therefore, an analytical method for simultaneous quantification of P-CTX-1, P-CTX-2, and P-CTX-3 in whole blood of marketed coral reef fish using sonication, solid-phase extraction (SPE), and liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed. The optimized method gave acceptable recoveries of P-CTXs (74-103 %) in fish blood. Matrix effects (6-26 %) in blood extracts were found to be significantly reduced compared with those in muscle extracts (suppressed by 34-75 % as reported in other studies), thereby minimizing potential for false negative results. The target P-CTXs were detectable in whole blood from four coral reef fish species collected in a CFP-endemic region. Similar trends in total P-CTX levels and patterns of P-CTX composition profiles in blood and muscle of these fish were observed, suggesting a relationship between blood and muscle levels of P-CTXs. This optimized method provides an essential tool for studies of P-CTX pharmacokinetics and pharmacodynamics in fish, which are needed for establishing the use of fish blood as a reliable sample for the assessment and control of CFP. PMID:23392409

  1. Tandem mass spectrometry of kahalalides: Identification of two new cyclic depsipeptides, kahalalide R and S from Elysia grandifolia

    Digital Repository Service at National Institute of Oceanography (India)

    Tilvi, S.; Naik, C.G.

    depsipeptide anticancer drug kahalalide F in human plasma by high-performance liquid chromatography under basic conditions coupled to electrospray ionization tandem mass spectrometry. J. Mass Spectrom. 2002; 37: 992. 39. Hanno S, Bernhard K, Matthias M... voltage-5700 V; Declustering potential (DP)-120V; Focusing potential (FP)-365V; Declustering potential (DP2)-14V and Collision gas (CAD) 3 (arbitrary units). Full-scan data acquisition was performed, scanning from m/z 100 to m/z 2000 in profile mode...

  2. Application of liquid chromatography-tandem mass spectrometry in quantitative bioanalyses of organic molecules in aquatic environment and organisms.

    Science.gov (United States)

    Bussy, Ugo; Li, Ke; Li, Weiming

    2016-05-01

    Analytical methods using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of metabolites or contaminants (or both) in various tissues of aquatic organisms and in the aquatic environment have received increasing attention in the last few years. This review discusses the findings relevant to such procedures published between 2005 and 2015. The aim is to evaluate the advantages, restrictions, and performances of the procedures from sample preparation to mass spectrometry measurement. To support these discussions, a general knowledge on LC-MS/MS is also provided. PMID:26996906

  3. Analysis of a series of chlorogenic acid isomers using differential ion mobility and tandem mass spectrometry.

    Science.gov (United States)

    Willems, Jamie L; Khamis, Mona M; Mohammed Saeid, Waleed; Purves, Randy W; Katselis, George; Low, Nicholas H; El-Aneed, Anas

    2016-08-24

    Chlorogenic acids are among the most abundant phenolics found in the human diet. Of these, the mono-caffeoylquinic acids are the predominant phenolics found in fruits, such as apples and pears, and products derived from them. In this research, a comprehensive study of the electrospray ionization (ESI) tandem mass spectrometric (MS/MS) dissociation behavior of the three most common mono-caffeoylquinic acids, namely 5-O-caffeoylquinic acid (5-CQA), 3-O-caffeoylquinic acid (3-CQA) and 4-O-caffeoylquinic acid (4-CQA), were determined using both positive and negative ionization. All proposed structures of the observed product ions were confirmed with second-generation MS(3) experiments. Similarities and differences between the dissociation pathways in the positive and negative ion modes are discussed, confirming the proposed structures and the established MS/MS fingerprints. MS/MS dissociation was primarily driven via the cleavage of the ester bond linking the quinic acid moiety to the caffeic acid moiety within tested molecules. Despite being structural isomers with the same m/z values and dissociation behaviors, the MS/MS data in the negative ion mode was able to differentiate the three isomers based on ion intensity for the major product ions, observed at m/z 191, 179 and 173. This differentiation was consistent among various MS instruments. In addition, ESI coupled with high-field asymmetric waveform ion mobility spectrometry-mass spectrometry (ESI-FAIMS-MS) was employed for the separation of these compounds for the first time. By combining MS/MS data and differential ion mobility, a method for the separation and identification of mono-caffeoylquinic in apple/pear juice samples was developed with a run time of less than 1 min. It is envisaged that this methodology could be used to identify pure juices based on their chlorogenic acid profile (i.e., metabolomics), and could also be used to detect juice-to-juice adulteration (e.g., apple juice addition to pear juice

  4. Evaluation of relative isotopic abundance measurements in a quadrupole time-of-flight mass spectrometer for elemental composition determination of natural products in traditional Chinese medicine.

    Science.gov (United States)

    Wu, Zhi-Jun; Huo, Jia-Li; Chen, Jian-Zhong; Li, Na; Fang, Dong-Mei; Chen, Xiao-Zhen; Zhang, Guo-Lin; Wang, Jian-Hua; Xu, Xiao-Ying

    2013-01-01

    The relative isotopic abundance (RIA) measurement errors of a quadrupole time-of-flight (Q-ToF) instrument incorporating analog-to-digital converter detectors were systemically evaluated by stochastically collecting about 200 data in positive ion mass spectrometry (MS) mode. Errors varied with peak intensities at definite spectral acquisition rates but were very close, even if peak intensities changed sharply at different spectral acquisition rates with the same concentration. Intensity thresholds were systematically defined at 1 Hz of spectral acquisition rates. RIA measurement errors were also evaluated using peak area. It seemed that peak area was better adapted for the high-intensity ions while peak intensity was suited for very low-intensity ions. Several known compounds were selected for RIA measurements for product ions in tandem mass spectropmetry (MS/MS) mode. An extract of a representative traditional Chinese medicinal, Paederia scandens was analyzed with high-performance liquid chromatography-electrospray ionization-QToF-MS/MS. The unique elemental compositions of some compounds could not be identified even with exact masses and MS/MS spectra of measured and reference compounds. RIA errors, especially of (M+2)M(-1), provided vital information for determining the elemental composition. PMID:24261081

  5. A generic method to identify plant viruses by high-resolution tandem mass spectrometry of their coat proteins.

    Science.gov (United States)

    Blouin, Arnaud G; Greenwood, David R; Chavan, Ramesh R; Pearson, Michael N; Clover, Gerard R G; MacDiarmid, Robin M; Cohen, Daniel

    2010-01-01

    Although a number of protocols have been developed for detection of viruses at the genus or family level, universal approaches to detect and identify unknown viruses are still required. High-resolution tandem mass spectrometry was used to identify accurately peptide masses and their constituent sequences from partially purified plant virus preparations. Analysis of the peptide fragment masses against a virus database using pattern-matching algorithms identified sequences with homology to known virus peptides and also predicted peptides using de novo sequence analysis. This method provided sufficient information to confirm the identity of two known viruses that were included as controls (Cucumber mosaic virus and Tomato spotted wilt virus) and to identify unknown viruses in six viral isolates. The unknown viruses have been identified as four common viruses (Alfalfa mosaic virus, Tobacco streak virus, Citrus leaf blotch virus and Ribgrass mosaic virus), and two novel viruses (a potexvirus and a vitivirus). The identification of viruses from five distinct families by the tandem mass spectrometric determination of their coat protein demonstrates that this is a useful method for initial virus identification. This method, complemented with molecular or immunological procedures, provides a rapid and convenient way to identify both known and novel plant viruses. PMID:19712699

  6. Quantification of neurotransmitters in mouse brain tissue by using liquid chromatography coupled electrospray tandem mass spectrometry.

    Science.gov (United States)

    Kim, Tae-Hyun; Choi, Juhee; Kim, Hyung-Gun; Kim, Hak Rim

    2014-01-01

    A simple and rapid liquid chromatography tandem mass spectrometry method has been developed for the determination of BH4, DA, 5-HT, NE, EP, Glu, and GABA in mouse brain using epsilon-acetamidocaproic acid and isotopically labeled neurotransmitters as internal standards. Proteins in the samples were precipitated by adding acetonitrile, and then the supernatants were separated by a Sepax Polar-Imidazole (2.1 mm × 100 mm, i.d., 3 μm) column by adding a mixture of 10 mM ammonium formate in acetonitrile/water (75 : 25, v/v, 300 μl/min) for BH4 and DA. To assay 5-HT, NE, EP, Glu, and GABA; a Luna 3 μ C18 (3.0 mm × 150 mm, i.d., 3 μm) column was used by adding a mixture of 1% formic acid in acetonitrile/water (20 : 80, v/v, 350 μl/min). The total chromatographic run time was 5.5 min. The method was validated for the analysis of samples. The calibration curve was linear between 10 and 2000 ng/g for BH4 (r(2) = 0.995) , 10 and 5000 ng/g for DA (r(2) = 0.997) , 20 and 10000 ng/g for 5-HT (r(2) = 0.994) , NE (r(2) = 0.993) , and EP (r(2) = 0.993) , and 0.2 and 200 μg/g for Glu (r(2) = 0.996) and GABA (r(2) = 0.999) in the mouse brain tissues. As stated above, LC-MS/MS results were obtained and established to be a useful tool for the quantitative analysis of BH4, DA, 5-HT, NE, EP, Glu, and GABA in the experimental rodent brain. PMID:25258696

  7. Detection of 10 sweeteners in various foods by liquid chromatography/tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Chui-Shiang Chang

    2014-09-01

    Full Text Available The analytical method for sweeteners in various food matrixes is very important for food quality control and regulation enforcement. A simple and rapid method for the simultaneous determination of 10 sweeteners [acesulfame potassium (ACS-K, aspartame (ASP, cyclamate (CYC, dulcin (DUL, glycyrrhizic acid (GA, neotame (NEO, neohesperidin dihydrochalcone (NHDC, saccharin (SAC, sucralose (SCL, and stevioside (STV] in various foods by liquid chromatography/tandem mass chromatography (LC–MS/MS was developed. The chromatographic separation was performed on a Phenomenex Luna Phenyl-Hexyl (5 μm, 4.6 mm × 150 mm column with gradient elution of 10 mM ammonium acetate in water and 10 mM ammonium acetate in methanol. The recoveries of the 10 sweeteners were between 75% and 120%, and the coefficients of variation were less than 20%. The limits of quantification were 0.5 μg/kg for NHDC and SCL. For the other sweeteners, the limits of quantification were 0.1 μg/kg. Compared to the traditional high-performance liquid chromatography method, the LC–MS/MS method could provide better sensitivity, higher throughput, enhanced specificity, and more sweeteners analyzed in a single run. The samples included 27 beverages (16 alcoholic and 11 nonalcoholic beverages and 15 pickled foods (1 pickled pepper, 3 candies, and 11 candied fruits. Two remanufactured wines were found to contain 7.2, 8.5 μg/g SAC and 126.5, 123 μg/g CYC, respectively. ACS-K, ASP, SCL, and NEO were detected in five beverages and drinks. The pickled peppers and candied fruits were found to contain SAC, GA, CYC, ASP, STV, NEO, and ACS-K. The wine with sweeteners detected was remanufactured wine, not naturally fermented wine. Therefore, the ingredient label for the sweeteners of remanufactured wine should be regulated by the proper authority for inspection of sweeteners.

  8. Sensitive, Preclinical Detection of Prions in Brain by nanospray liquid chromatography/tandem mass spectrometry

    Science.gov (United States)

    More sensitive detection of prions in brain is important because it would allow early detection of disease in young animals and assure a safer food supply. We quantitated the amount of proteinase K-resistant prion protein (PrP 27-30) by use of nano-scale liquid chromatography coupled to a tandem ma...

  9. Quantification of Modified Tyrosines in Healthy and Diabetic Human Urine using Liquid Chromatography/Tandem Mass Spectrometry

    OpenAIRE

    Kato, Yoji; Dozaki, Natsuko; Nakamura, Toshiyuki; Kitamoto, Noritoshi; Yoshida, Akihiro; Naito, Michitaka; Kitamura, Masayasu; Osawa, Toshihiko

    2008-01-01

    The quantification of urinary oxidized tyrosines, dityrosine (DiY), nitrotyrosine (NY), bromotyrosine (BrY), and dibromotyrosine (DiBrY), was accomplished by quadruple liquid chromatography-tandem mass spectrometry (LC/MS/MS). The sample was partially purified by solid phase extraction, and was then applied to the LC/MS/MS using multiple-reaction monitoring (MRM) methods. The analysis for the DiY quantification was done first. The residual samples were further butylated with n-butanol/HCl, an...

  10. Optimizing TiO2-based phosphopeptide enrichment for automated multidimensional liquid chromatography coupled to tandem mass spectrometry

    OpenAIRE

    Cantin, Greg T.; Shock, Teresa R.; Park, Sung Kyu; Madhani, Hiten D.; Yates, John R.

    2007-01-01

    An automated online multidimensional liquid chromatography system coupled to ESI-based tandem mass spectrometry was used to assess the effectiveness of TiO2 in the enrichment of phosphopeptides from tryptic digests of protein mixtures. By monitoring the enrichment of phosphopeptides, an optimized set of loading, wash, and elution conditions were realized for TiO2. A comparison of TiO2 with other resins used for phosphopeptide enrichment, Fe(III)-IMAC and ZrO2, was also carried out using trypt...

  11. The application of Guided Ion Beam Tandem Mass Spectrometer; Bond dissociation energies of bare and ligated copper group cluster anions

    International Nuclear Information System (INIS)

    Threshold energies, fragmentation patterns, and integral cross sections for the reactions of collision induced dissociations of bare and ligated copper group cluster anions are determined using a Guided Ion Beam Tandem Mass Spectrometer (GIB-MS). The bond breaking patterns for the copper cluster anions show dramatic even/odd tendencies, e.g., all copper group anions generate as the predominant reaction product, Carbon monoxide is weakly bound to copper group cluster anions. Cohesive energies of the bare copper and silver cluster anions are determined and exhibit a good correspondence with estimate cohesive energies by the model of Miedema.

  12. Identification of Perfluorooctanoic Acid Release from Commercial Coated Cooking Pans by Liquid Chromatography Coupled to Electrospray Ionization Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Monica Bononi

    2007-01-01

    Full Text Available Salts of perfluorooctanoic acid (PFOA can be used in the manufacture of fluoropolymers employed for coating pans; moreover, PFOA can be formed as a byproduct of thermolysis of the aforesaid fluoropolymers. This study was carried out to evaluate PFOA migration into food cooked in fluoropolymer-coated pans. The pans were purchased from a local retailer and subjected to cooking conditions. Used oil was extracted with a methanol/water solution and analyzed by liquid chromatography tandem mass spectrometry (LC/MS/MS. We found that PFOA can enter cooked food during a container's first phases of use, not only in containers already abused by kitchen tools or otherwise scratched.

  13. Rapid quantification of the metabolite of valacyclovir hydrochloride in human plasma by liquid chromatography-tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Objective To establish a rapid,sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of acyclovir (the metabolite of valacyclovir hydrochloride) in human plasma. Methods After addition of ganciclovir as internal standard (IS),plasma samples were prepared by one-step protein precipitation using acetonitrile as precipitant,followed by an isocratic elution with 0.1% formic acid solution-methanol (95∶5,v/v) on an Agilent ZORBAX SB-C18 (150mm×2.1mm i.d.,3....

  14. High-Performance Liquid Chromatographic-Tandem Mass Spectrometric Determination of Itraconazole in Human Plasma for Bioavailability and Bioequivalence Studies

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Wook; Nam, Dae Young; Kang, Kyoung Hoon; Ha, Kyung Wook; Han, In Hee; Chang, Byung Kon; Yoon, Mi Kyeong; Lee, Jae Hwi [Chung-Ang University, Seoul (Korea, Republic of)

    2006-02-15

    A highly sensitive high-performance liquid chromatographic-tandem mass spectrometric method (HPLC-MSMS) has been developed to quantify itraconazole in human plasma for the purpose of pharmacokinetic studies. Sample preparation was carried out by liquid-liquid extraction using loratadine as an internal standard. Chromatographic separation used a YMC C{sub 18} column, giving an extremely fast total run time of 3 min. The method was validated and used for the bioequivalence study of itraconazole tablets in healthy male volunteers (n = 31). The lower limit of detection proved to be 0.2 ng /mL for itraconazole.

  15. High-Performance Liquid Chromatographic-Tandem Mass Spectrometric Determination of Itraconazole in Human Plasma for Bioavailability and Bioequivalence Studies

    International Nuclear Information System (INIS)

    A highly sensitive high-performance liquid chromatographic-tandem mass spectrometric method (HPLC-MSMS) has been developed to quantify itraconazole in human plasma for the purpose of pharmacokinetic studies. Sample preparation was carried out by liquid-liquid extraction using loratadine as an internal standard. Chromatographic separation used a YMC C18 column, giving an extremely fast total run time of 3 min. The method was validated and used for the bioequivalence study of itraconazole tablets in healthy male volunteers (n = 31). The lower limit of detection proved to be 0.2 ng /mL for itraconazole

  16. Transmission Mode Ion/Ion Reactions in the RF-only Ion Guide of Hybrid Tandem Mass Spectrometers

    OpenAIRE

    Emory, Joshua F; Hassell, Kerry H.; Londry, Frank A.; McLuckey, Scott A.

    2009-01-01

    Transmission mode ion/ion reactions have been performed within the first quadrupole, the Q0 RF-only quadrupole, of two types of hybrid tandem mass spectrometers (viz., triple quadrupole/linear ion trap and QqTOF instruments). These transmission mode reactions involved the storage of either the reagent species and the transmission of the analyte species through the Q0 quadrupole for charge inversion reactions or the storage of the analyte ions and transmission of the reagent ions as in charge ...

  17. Performing protein crosslinking using gas-phase cleavable chemical crosslinkers and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Argo, Andrew S; Shi, Chunxiao; Liu, Fan; Goshe, Michael B

    2015-11-01

    In this article, we describe our methods and protocols using collision-induced dissociative chemical crosslinking-tandem mass spectrometry (CID-CXL-MS/MS) analysis and the practical considerations when implementing these reagents and methodology for protein crosslinking studies. The synthesis of our novel chemical crosslinkers is described as well as their use for effectively labeling protein and protein complexes. Several sample preparation methods for liquid chromatography-tandem mass spectrometry are provided including the enrichment of interpeptide crosslinks. For identification of CID-CXL-MS/MS crosslinks, details regarding MS acquisition parameters and the utilization of various mass spectrometers are addressed along with post-data acquisition analysis to identify interpeptide crosslinks. Once the CID-CXL-MS/MS approach is optimized for a protein target or a set of targets, it can be used as a tool for biological research for studying protein structure when integrated with data obtained using other techniques, such as NMR, X-ray crystallography, and cryo-electron microscopy, or extended to the study of protein-protein interactions in physiological environments. PMID:26091612

  18. Pivotal Role of Computers and Software in Mass Spectrometry - SEQUEST and 20 Years of Tandem MS Database Searching

    Science.gov (United States)

    Yates, John R.

    2015-11-01

    Advances in computer technology and software have driven developments in mass spectrometry over the last 50 years. Computers and software have been impactful in three areas: the automation of difficult calculations to aid interpretation, the collection of data and control of instruments, and data interpretation. As the power of computers has grown, so too has the utility and impact on mass spectrometers and their capabilities. This has been particularly evident in the use of tandem mass spectrometry data to search protein and nucleotide sequence databases to identify peptide and protein sequences. This capability has driven the development of many new approaches to study biological systems, including the use of "bottom-up shotgun proteomics" to directly analyze protein mixtures.

  19. Determination of polar pesticides in olive oil and olives by hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry and high resolution mass spectrometry.

    Science.gov (United States)

    Nortes-Méndez, Rocío; Robles-Molina, José; López-Blanco, Rafael; Vass, Andrea; Molina-Díaz, Antonio; Garcia-Reyes, Juan F

    2016-09-01

    This article reports the development of two HPLC-MS methods for the determination of polar pesticides in olive oil and olive samples by hydrophilic interaction liquid chromatography (HILIC) separation followed by mass spectrometry detection with tandem mass spectrometry using a triple quadrupole instrument operated in multiple reaction monitoring mode (HILIC-MS/MS) or electrospray time-of-flight mass spectrometry (HILIC-TOFMS). The selected polar pesticides included in the study were: amitrol, cyromazine, diquat, paraquat, mepiquat, trimethylsulfonium (trimesium, glyphosate counterion) and fosetyl aluminium. The simple sample treatment procedure was based on liquid partitioning with methanol. The performance of the sample extraction was evaluated in terms of recovery rates and matrix effects in both olive oil and olives matrices. The results obtained for olive oil were satisfactory while, due to the high complexity of olives, poor recovery rates were obtained for the extraction of diquat, paraquat and amitrol, although with a reasonable precision enabling its use in routine analysis. Similarly, matrix effects were minor in the case of olive oil (ca. 20% suppression average), while significantly higher suppression was observed for olives (30-50% suppression average). The studied approaches were found to be useful for the determination of the pesticides studied in olive oil and olives with limits of quantitation below 5µgkg(-1) in most cases when tandem mass spectrometry was used, thus being in compliance with MRLs set by current EU regulation. PMID:27343599

  20. Chiral liquid chromatography-mass spectrometry (LC-MS/MS) method development for the detection of salbutamol in urine samples.

    Science.gov (United States)

    Chan, Sue Hay; Lee, Warren; Asmawi, Mohd Zaini; Tan, Soo Choon

    2016-07-01

    A sequential solid-phase extraction (SPE) method was developed and validated using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) for the detection and quantification of salbutamol enantiomers in porcine urine. Porcine urine samples were hydrolysed with β-glucuronidase/arylsulfatase from Helix pomatia and then subjected to a double solid-phase extraction (SPE) first using the Abs-Elut Nexus SPE and then followed by the Bond Elut Phenylboronic Acid (PBA) SPE. The salbutamol enantiomers were separated using the Astec CHIROBIOTIC™ T HPLC column (3.0mm×100mm; 5μm) maintained at 15°C with a 15min isocratic run at a flow rate of 0.4mL/min. The mobile phase constituted of 5mM ammonium formate in methanol. Salbutamol and salbutamol-tert-butyl-d9 (internal standard, IS) was monitored and quantified with the multiple reaction monitoring (MRM) mode. The method showed good linearity for the range of 0.1-10ng/mL with limit of quantification at 0.3ng/mL. Analysis of the QC samples showed intra- and inter-assay precisions to be less than 5.04%, and recovery ranging from 83.82 to 102.33%. PMID:27232053

  1. Quantitative Mass Spectrometry for Bacterial Protein Toxins — A Sensitive, Specific, High-Throughput Tool for Detection and Diagnosis

    Directory of Open Access Journals (Sweden)

    Suzanne Kalb

    2011-03-01

    Full Text Available Matrix-assisted laser-desorption time-of-flight (MALDI-TOF mass spectrometry (MS is a valuable high-throughput tool for peptide analysis. Liquid chromatography electrospray ionization (LC-ESI tandem-MS provides sensitive and specific quantification of small molecules and peptides. The high analytic power of MS coupled with high-specificity substrates is ideally suited for detection and quantification of bacterial enzymatic activities. As specific examples of the MS applications in disease diagnosis and select agent detection, we describe recent advances in the analyses of two high profile protein toxin groups, the Bacillus anthracis toxins and the Clostridium botulinum neurotoxins. The two binary toxins produced by B. anthracis consist of protective antigen (PA which combines with lethal factor (LF and edema factor (EF, forming lethal toxin and edema toxin respectively. LF is a zinc-dependent endoprotease which hydrolyzes specific proteins involved in inflammation and immunity. EF is an adenylyl cyclase which converts ATP to cyclic-AMP. Toxin-specific enzyme activity for a strategically designed substrate, amplifies reaction products which are detected by MALDI-TOF-MS and LC-ESI-MS/MS. Pre-concentration/purification with toxin specific monoclonal antibodies provides additional specificity. These combined technologies have achieved high specificity, ultrasensitive detection and quantification of the anthrax toxins. We also describe potential applications to diseases of high public health impact, including Clostridium difficile glucosylating toxins and the Bordetella pertussis adenylyl cyclase.

  2. Screening for estrogen residues in calf urine: Comparison of a validated yeast estrogen bioassay and gas chromatography-tandem mass spectrometry

    NARCIS (Netherlands)

    Nielen, M.W.F.; Bovee, T.F.H.; Heskamp, H.H.; Lasaroms, J.J.P.; Sanders, M.B.; Rhijn, van J.A.; Groot, M.J.; Hoogenboom, L.A.P.

    2006-01-01

    Within the European Union, the control for residues of illegal hormones in food-producing animals is based on urine analysis for a few target analytes using gas chromatography/mass spectrometry and/or liquid chromatography¿tandem mass spectrometry. Recently, we developed a robust yeast bioassay scre

  3. Analysis of triptophenolide and its related compounds from Tripterygium wilfordii Hook.f by electrospray ionization tandem mass spectrometry

    Science.gov (United States)

    Li, Rui; Peng, Aihua; He, Chunmei; Wang, Xianhuo; Shi, Jianyou; Chen, Lijuan; Wei, Yuquan

    2008-11-01

    Triptophenolide and its related compounds from Tripterygium wilfordii Hook.f is a kind of diterpenoids which shows anti-inflammatory activity. To study the metabolites of triptophenolide related compounds, the fragmentation mechanisms of them were investigated by using negative electrospray tandem mass spectrometry. With the aid of high resolution of ESI-QTOF-MS/MS, the fragmentation mechanisms of six diterpenoid compounds were systematically investigated. The fragmentation behavior mainly depends on what substituent groups the benzyl C ring bears. If there is a hydroxyl group on the position of C14, loss of CH4 is dominating. However, the successive loss of two CH3 radicals is predominant when the hydroxyl group of O14 is methylated. The lactone ring is prone to be dissociated to loss of CO, CO2 and C2H2O2 molecules. The pericyclic reaction can occur on A ring if there is an active hydrogen resides on C ring. Furthermore, one metabolite of compound A1 was confirmed by cytochrome P450 in vitro and the structure was proposed by tandem mass experiment together with the fragmentation mechanisms of this type of compounds.

  4. Determination of azithromycin residue in pork using a molecularly imprinted monolithic microcolumn coupled to liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Tong; Yang, Haicui; Jin, Zhen; Liu, Qingying; Song, Xuqin; He, Limin; Fang, Binghu; Meng, Chenying

    2016-04-01

    Using spiramycin as a dummy template, a molecularly imprinted polymer monolithic micro-column with high selection to azithromycin was prepared in a micropipette tip. The imprinting factor of the monolithic micro-column prepared was approximately 2.67 and the morphological structure of the polymers was characterized by scanning electron microscopy. A simple, sensitive, and reproducible method based on the imprinted monolithic micro-column coupled to liquid chromatography with tandem mass spectrometry was developed for determining the residues of azithromycin in pork. Pork samples were extracted with acetonitrile, cleaned up under the optimal monolithic micro-column conditions, and analyzed using liquid chromatography with tandem mass spectrometry in the multiple reaction monitoring mode. The assay exhibited a linear dynamic range of 0.50-50 μg/L with the correlation coefficient (r(2) ) above 0.99. In the three spiking levels of 0.50, 1.0, and 10 μg/kg, the average recoveries of azithromycin from pork samples were between 85.8 and 96.5% with a relative standard deviation below 10%. The limit of detection and limit of quantitation were 0.03 and 0.1 μg/kg, respectively. PMID:26854282

  5. Rapid Determination of Imatinib in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study

    International Nuclear Information System (INIS)

    A simple, fast and robust analytical method was developed to determine imatinib in human plasma using liquid chromatography-tandem mass spectrometry with electrospray ionization in the positive ion mode. Imatinib and labeled internal standard were extracted from plasma with a simple protein precipitation. The chromatographic separation was performed using an isocratic elution of mobile phase involving 5.0 mM ammonium formate in water -5.0 mM ammonium formate in methanol (30:70, v/v) over 3.0 min on reversed-stationary phase. The detection was performed using a triple-quadrupole tandem mass spectrometer in multiple-reaction monitoring mode. The developed method was validated with lower limit of quantification of 10 ng/mL. The calibration curve was linear over 10-2000 ng/mL (R2 > 0.99). The method validation parameters met the acceptance criteria. The spiked samples and standard solutions were stable under conditions for storage and handling. The reliable method was successfully applied to real sample analyses and thus a pharmacokinetic study in 27 healthy Korean male volunteers

  6. A simple and selective liquid chromatography- tandem mass spectrometry method for determination of ε-aminocaproic acid in human plasma

    Directory of Open Access Journals (Sweden)

    Ganesh S. Moorthy

    2015-07-01

    Full Text Available Understanding the clinical pharmacology of the antifibrinolytic drug epsilon-aminocaproic acid (EACA is critical for rational drug administration in children. The aim of this study is to develop a reliable assay for the determination of EACA in human plasma. We describe a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS assay for EACA in human plasma. Sample preparation involved plasma dilution (1:2040, followed by reversed-phase chromatographic separation and selective detection using tandem mass spectrometry. EACA had a linear range of 1 - 250 μg/mL. The intraday precision based on the standard deviation of replicates of quality control samples ranged from 4.7 to 10.4% and the accuracy ranged from 92-106%. The interday precision ranged from 4.6 to 9.8% and the accuracy ranged from 95-103%. Stability studies showed that EACA was stable during the conditions for sample preparation and storage. The described method is robust and successfully employed for clinical studies of EACA in children

  7. Determination of dexmedetomidine in children's plasma by ultra-performance liquid chromatography tandem mass spectrometry and application to pharmacokinetic study.

    Science.gov (United States)

    Liu, Hua-Cheng; Sun, Wei; Wang, Cheng-Yu; Ying, Wei-Yang; Zheng, Li-Dan; Zeng, Rui-Feng; Wang, Zhe; Ge, Ren-Shan

    2016-06-15

    A rapid, sensitive, and selective ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was developed and validated for the determination and pharmacokinetic investigation of dexmedetomidine in children's plasma. Sample preparation was accomplished through a simple one-step deproteinization procedure with 0.2mL of acetonitrile to a 0.1mL plasma sample. Plasma samples were separated by UPLC on an Acquity UPLC BEH C18 column using a mobile phase consisting of acetonitrile-0.1% formic acid in water with gradient elution. The total run time was 3.1min and the elution of dexmedetomidine was at 1.24min. The detection was performed on a triple quadrupole tandem mass spectrometer in the multiple reaction-monitoring mode using the respective transitions m/z 201.3→95.1 for dexmedetomidine and m/z 204.2→98.0 for the internal standard, respectively. The calibration curve was linear over the range of 0.05-10ng/mL with a lower limit of quantitation of 0.05ng/mL. Mean recovery rate of dexmedetomidine in plasma was in the range of 86.7-89.1%. Intra-day and inter-day precision were both <11.6%. This method was successfully applied in pharmacokinetic study after commencement of 1.0μg/kg dexmedetomidine infusion in children. PMID:27179189

  8. Sensitive liquid chromatography-tandem mass spectrometry method for the simultaneous determination of paracetamol and guaifenesin in human plasma.

    Science.gov (United States)

    Chen, Xiaoyan; Huang, Jia; Kong, Zhang; Zhong, Dafang

    2005-03-25

    A rapid and sensitive method for the simultaneous determination of paracetamol and guaifenesin in human plasma was developed and validated, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. After extracted from plasma samples by diethyl ether-dichloromethane (3:2, v/v), the analytes and internal standard osalmide were chromatographed on a C18 column. Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via atmospheric pressure chemical ionization (APCI). The method was linear in the concentration range of 0.05-20.0 microg/ml for paracetamol and 5.0-2000.0 ng/ml for guaifenesin. The intra- and inter-day precision was within 14% for both paracetamol and guaifenesin. The assay accuracy was within +/-2.4% for the analytes. This is the first assay method described for the simultaneous determination of paracetamol and guaifenesin in plasma using one chromatographic run. The method was successfully employed in a pharmacokinetic study after an oral administration of a multicomponent formulation, containing 650 mg paracetamol, 200 mg guaifenesin, 60 mg pseudoephedrine and 20 mg dextrorphan. PMID:15686994

  9. Characterization of oncogene-induced metabolic alterations in hepatic cells by using ultrahigh performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tang, Zhi; Cao, Tingting; Lin, Shuhai; Fu, Li; Li, Shangfu; Guan, Xin-Yuan; Cai, Zongwei

    2016-05-15

    Elucidation of altered metabolic pathways by using metabolomics may open new avenues for basic research on disease mechanisms and facilitate the development of novel therapeutic strategies. Here, we report the development of ultrahigh performance liquid chromatography-tandem mass spectrometry-based metabolomics platform with capability of measuring both cationic and anionic intermediates in cellular metabolism. The platform was established based on the hydrophobic ion-pairing interaction chromatography coupled with tandem mass spectrometry in multiple reaction monitoring (MRM) mode. The MRM transitions were created and optimized via energy-resolved collision-induced dissociation experiments, serving as an essential reference point for the quantification and identification. For chromatographic separation, application of hydrophobic ion-pairing interaction led to dramatic enhancement on retention of water-soluble metabolites and provision of good peak shapes. Two volatile ion-pairing reagents, namely heptafluorobutyric acid and tributylamine, were used with dedicated C18 columns as complementary separation systems coupled with the MRM analysis, allowing measurement of the metabolites of interest at nanomolar levels. The developed platform was successfully applied to investigate the altered metabolism in hepatic cells with over-expression of an oncogene, thus can provide important information on the rewired metabolism. PMID:26992502

  10. Rapid Determination of Imatinib in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jeong Soo; Cho, Eun Gi; Huh, Wooseong; Ko, Jaewook; Jung, Jin Ah; Lee, Sooyoun [Samsung Medical Center, Seoul (Korea, Republic of)

    2013-08-15

    A simple, fast and robust analytical method was developed to determine imatinib in human plasma using liquid chromatography-tandem mass spectrometry with electrospray ionization in the positive ion mode. Imatinib and labeled internal standard were extracted from plasma with a simple protein precipitation. The chromatographic separation was performed using an isocratic elution of mobile phase involving 5.0 mM ammonium formate in water -5.0 mM ammonium formate in methanol (30:70, v/v) over 3.0 min on reversed-stationary phase. The detection was performed using a triple-quadrupole tandem mass spectrometer in multiple-reaction monitoring mode. The developed method was validated with lower limit of quantification of 10 ng/mL. The calibration curve was linear over 10-2000 ng/mL (R{sup 2} > 0.99). The method validation parameters met the acceptance criteria. The spiked samples and standard solutions were stable under conditions for storage and handling. The reliable method was successfully applied to real sample analyses and thus a pharmacokinetic study in 27 healthy Korean male volunteers.

  11. Modification of a tandem mass-spectrometer for infrared multi-photon dissociation (IRMPD) of gas-phase ions

    Science.gov (United States)

    Gillis, Julie M.; Osburn, Sandra M.; van Stipdonk, Michael J.; Corcovilos, Theodore A.

    2015-05-01

    Infrared multi-photon dissociation (IRMPD) is a method of fragmenting molecular ions for structural analysis of the parent molecule. The target ions absorb many photons, increasing the vibrational state of the excited bonds until the dissociation occurs. We have modified a commercial linear quadrupole trap tandem mass spectrometer (Thermo-Fisher LTQ) by installing a removable high-vacuum window in the rear accessory plate of the mass spectrometer. The window allows us to inject laser light into the ion trap. The shape of the injected laser beam is optimized to match the volume of the ion cloud within the ion trap, improving IRMPD efficiency. We present preliminary data of the IRMPD of weakly bound uranyl-acetone and uranyl-dimethyl sulfoxide clusters using a 20-W pulsed CO2 laser (wavelength 10 . 6 μm), showing previously undetected fragmentation products.

  12. Liquid chromatography-tandem mass spectrometry for the analysis of eicosanoids and related lipids in human biological matrices: a review.

    Science.gov (United States)

    Kortz, Linda; Dorow, Juliane; Ceglarek, Uta

    2014-08-01

    Today, there is an increasing number of liquid chromatography tandem-mass spectrometric (LC-MS/MS) methods for the analysis of eicosanoids and related lipids in biological matrices. An overview of currently applied LC-MS/MS methods is given with attention to sample preparation strategies, chromatographic separation including ultra high performance liquid chromatography (UHPLC) and chiral separation, as well as to mass spectrometric detection using multiple reacting monitoring (MRM). Further, the application in recent clinical research is reviewed with focus on preanalytical aspects prior to LC-MS/MS analysis as well as applications in major diseases of Western civilization including respiratory diseases, diabetes, cancer, liver diseases, atherosclerosis, and neurovascular diseases. PMID:24583205

  13. Identification of the Related Substances in Ampicillin Capsule by Rapid Resolution Liquid Chromatography Coupled with Electrospray Ionization Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Lei Zhang

    2014-01-01

    Full Text Available Rapid Resolution Liquid Chromatography coupled with Electrospray Ionization Tandem Mass Spectrometry (RRLC-ESI-MSn was used to separate and identify related substances in ampicillin capsule. The fragmentation behaviors of related substances were used to identify their chemical structures. Finally, a total of 13 related substances in ampicillin capsule were identified, including four identified components for the first time and three groups of isomers on the basis of the exact mass, fragmentation behaviors, retention time, and chemical structures in the literature. This study avoided time-consuming and complex chemosynthesis of related substances of ampicillin and the results could be useful for the quality control of ampicillin capsule to guarantee its safety in clinic. In the meantime, it provided a good example for the rapid identification of chemical structures of related substances of drugs.

  14. Identification of the related substances in ampicillin capsule by rapid resolution liquid chromatography coupled with electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Lei; Cheng, Xian Long; Liu, Yang; Liang, Miao; Dong, Honghuan; Lv, Beiran; Yang, Wenning; Luo, Zhiqiang; Tang, Mingmin

    2014-01-01

    Rapid Resolution Liquid Chromatography coupled with Electrospray Ionization Tandem Mass Spectrometry (RRLC-ESI-MS(n)) was used to separate and identify related substances in ampicillin capsule. The fragmentation behaviors of related substances were used to identify their chemical structures. Finally, a total of 13 related substances in ampicillin capsule were identified, including four identified components for the first time and three groups of isomers on the basis of the exact mass, fragmentation behaviors, retention time, and chemical structures in the literature. This study avoided time-consuming and complex chemosynthesis of related substances of ampicillin and the results could be useful for the quality control of ampicillin capsule to guarantee its safety in clinic. In the meantime, it provided a good example for the rapid identification of chemical structures of related substances of drugs. PMID:25530907

  15. Analysis of the volatile compounds in Senecio scandens Buch-Ham by gas chromatography-tandem mass spectrometry based on diversified scan technologies.

    Science.gov (United States)

    Li, Sensen; Su, Yue; Guo, Yinlong

    2011-01-01

    Static headspace gas chromatography-tandem mass spectrometry was used to identify volatile compounds from Senecio scandens Buch-Ham. The elemental composition of compounds was confirmed by exploiting the tandem mass spectra of isotopic peaks from the precursor ion. Some isomers were well distinguished by the diversified scan technologies of tandem mass spectrometry (MS/MS). The MS/MS included a product ion scan, a precursor ion scan and a neutral loss scan. The results showed that 46 volatile compounds were completely identified, and the great of majority compounds were α-pinene (11.93%), n-caproaldehyde (9.02%) and dehydrosabinene (6.22%). This qualitative method is convenient and accurate and can be considered as a complementary identification method for the qualitative analysis of volatile compounds in complex samples. PMID:22006636

  16. Stable Isotope Labeling Strategy for Curcumin Metabolite Study in Human Liver Microsomes by Liquid Chromatography-Tandem Mass Spectrometry

    Science.gov (United States)

    Gao, Dan; Chen, Xiaowu; Yang, Xiaomei; Wu, Qin; Jin, Feng; Wen, Hongliang; Jiang, Yuyang; Liu, Hongxia

    2015-04-01

    The identification of drug metabolites is very important in drug development. Nowadays, the most widely used methods are isotopes and mass spectrometry. However, the commercial isotopic labeled reagents are usually very expensive, and the rapid and convenient identification of metabolites is still difficult. In this paper, an 18O isotope labeling strategy was developed and the isotopes were used as a tool to identify drug metabolites using mass spectrometry. Curcumin was selected as a model drug to evaluate the established method, and the 18O labeled curcumin was successfully synthesized. The non-labeled and 18O labeled curcumin were simultaneously metabolized in human liver microsomes (HLMs) and analyzed by liquid chromatography/mass spectrometry (LC-MS). The two groups of chromatograms obtained from metabolic reaction mixture with and without cofactors were compared and analyzed using Metabolynx software (Waters Corp., Milford, MA, USA). The mass spectra of the newly appearing chromatographic peaks in the experimental sample were further analyzed to find the metabolite candidates. Their chemical structures were confirmed by tandem mass spectrometry. Three metabolites, including two reduction products and a glucuronide conjugate, were successfully detected under their specific HLMs metabolic conditions, which were in accordance with the literature reported results. The results demonstrated that the developed isotope labeling method, together with post-acquisition data processing using Metabolynx software, could be used for fast identification of new drug metabolites.

  17. Generalized method for probability-based peptide and protein identification from tandem mass spectrometry data and sequence database searching.

    Science.gov (United States)

    Ramos-Fernández, Antonio; Paradela, Alberto; Navajas, Rosana; Albar, Juan Pablo

    2008-09-01

    Tandem mass spectrometry-based proteomics is currently in great demand of computational methods that facilitate the elimination of likely false positives in peptide and protein identification. In the last few years, a number of new peptide identification programs have been described, but scores or other significance measures reported by these programs cannot always be directly translated into an easy to interpret error rate measurement such as the false discovery rate. In this work we used generalized lambda distributions to model frequency distributions of database search scores computed by MASCOT, X!TANDEM with k-score plug-in, OMSSA, and InsPecT. From these distributions, we could successfully estimate p values and false discovery rates with high accuracy. From the set of peptide assignments reported by any of these engines, we also defined a generic protein scoring scheme that enabled accurate estimation of protein-level p values by simulation of random score distributions that was also found to yield good estimates of protein-level false discovery rate. The performance of these methods was evaluated by searching four freely available data sets ranging from 40,000 to 285,000 MS/MS spectra. PMID:18515861

  18. Cloud-point extraction is compatible with liquid chromatography coupled to electrospray ionization mass spectrometry for the determination of antazoline in human plasma.

    Science.gov (United States)

    Giebułtowicz, Joanna; Kojro, Grzegorz; Piotrowski, Roman; Kułakowski, Piotr; Wroczyński, Piotr

    2016-09-01

    Cloud-point extraction (CPE) is attracting increasing interest in a number of analytical fields, including bioanalysis, as it provides a simple, safe and environmentally-friendly sample preparation technique. However, there are only few reports on the application of this extraction technique in liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis. In this study, CPE was used for the isolation of antazoline from human plasma. To date, only one method of antazoline isolation from plasma exists-liquid-liquid extraction (LLE). The aim of this study was to prove the compatibility of CPE and LC-ESI-MS/MS and the applicability of CPE to the determination of antazoline in spiked human plasma and clinical samples. Antazoline was isolated from human plasma using Triton X-114 as a surfactant. Xylometazoline was used as an internal standard. NaOH concentration, temperature and Triton X-114 concentration were optimized. The absolute matrix effect was carefully investigated. All validation experiments met international acceptance criteria and no significant relative matrix effect was observed. The compatibility of CPE and LC-ESI-MS/MS was confirmed using clinical plasma samples. The determination of antazoline concentration in human plasma in the range 10-2500ngmL(-1) by the CPE method led to results which are equivalent to those obtained by the widely used liquid-liquid extraction method. PMID:27289300

  19. Determination of capsaicin, dihydrocapsaicin, and nonivamide in self-defense weapons by liquid chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Reilly, C A; Crouc, D J; Yost, G S; Fatah, A A

    2001-04-01

    Sensitive and selective liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) methods for the analysis of capsaicin, dihydrocapsaicin, and nonivamide in pepper spray products have been developed. Chromatographic separation of the capsaicinoid analogues was achieved using a reversed-phase HPLC column and a stepwise gradient of methanol and distilled water containing 0.1% (v/v) formic acid. Identification and quantification of the capsaicinoids was achieved by electrospray ionization single-stage mass spectrometry monitoring the protonated molecules of the internal standard (m/z 280), capsaicin (m/z 306), dihydrocapsaicin (m/z 308), and nonivamide (m/z 294) or by tandem mass spectrometry monitoring the appropriate precursor-to-product-ion transitions. The plot of concentration versus peak area ratio was linear over the range of 10-750 ng/ml using LC-MS and 10-500 ng/ml using LC-MS-MS. However, to accurately quantify the capsaicinoids in the pepper spray products calibration curves between 10 and 1000 ng were constructed and fit using a weighted quadratic equation. Using the quadratic curve, the accuracy of the assay ranged from 91 to 102% for all analytes. The intra-assay precision (RSD) for capsaicin was 2% at 25 ng/ml, 10% at 500 ng/ml, and 3% at 800 ng/ml. The inter-assay precision (RSD) for capsaicin was 6% at 25 ng/ml, 6% at 500 ng/ml, and 9% at 800 ng/ml. Similar values for inter- and intra-assay precision were experimentally obtained for both dihydrocapsaicin and nonivamide. The analysis of selected pepper spray products demonstrated that the capsaicinoid concentration in the products ranged from 0.7 to 40.5 microg/microl. PMID:11330795

  20. Determination of sulfadiazine in phosphate- and DOC-rich agricultural drainage water using solid-phase extraction followed by liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Bouyou, P.A. Léon; Weisser, Johan Juhl; Strobel, Bjarne W.

    2014-01-01

    . Determination of SDZ, spiked at a realistic concentration of 50 μg/L, in artificial drainage water (ADW) containing common and high levels of phosphate (0.05, 0.5, and 5 mg/L) gave recoveries between 70 and 92 % (relative standard deviation 7.4–12.9 %). Analysis of the same realistic concentration of SDZ in ADW......Trace levels of the veterinary antibiotic compound sulfadiazine (SDZ) can be determined in agricultural drainage water samples with this new method. Optimized sample pretreatment and solid-phase extraction was combined with liquid chromatography coupled to tandem mass spectrometry (SPE LC......, spiked with common and high levels of dissolved organic carbon (2, 6, and 15 mg/L) confirmed the possible adaptation of a tandem solid-phase extraction (strong anion exchange (SAX)-hydrophilic-lipophilic balance (HLB)) followed by liquid chromatography-tandem mass spectrometry methodology. Recoveries...

  1. Determination of salbutamol and salbutamol glucuronide in human urine by means of liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Mareck, Ute; Guddat, Sven; Schwenke, Anne;

    2012-01-01

    The determination of salbutamol and its glucuronide in human urine following the inhalative and oral administration of therapeutic doses of salbutamol preparations was performed by means of direct urine injection utilizing liquid chromatography-tandem mass spectrometry (LC-MS/MS) and employing d(3......)-salbutamol and d(3)-salbutamol glucuronide as internal standards. Unconjugated salbutamol was detected in all administration study urine samples. Salbutamol concentrations following inhalation were commonly (99%) below 1000 ng/ml whereas values after oral administration frequently (48%) exceeded this...... threshold. While salbutamol glucuronide was not detected in urine samples collected after inhalation of the drug, 26 out of 82 specimens obtained after oral application contained salbutamol glucuronide with a peak value of 63 ng/ml. The percentage of salbutamol glucuronide compared to unconjugated...

  2. Large pore dermal microdialysis and liquid chromatography-tandem mass spectroscopy shotgun proteomic analysis: a feasibility study

    DEFF Research Database (Denmark)

    Petersen, Lars J.; Sorensen, Mette A.; Codrea, Marius C.;

    2013-01-01

    HPLC systems, followed by tandem mass spectrometry (MS/MS) on a Quadrupole-TOF hybrid instrument. The MS/MS spectra were merged and mapped to a human target protein database to achieve peptide identification and protein inference. ResultsResults showed variation in protein amounts and profiles for each......Background/AimsThe purpose of the present pilot study was to investigate the feasibility of combining large pore dermal microdialysis with shotgun proteomic analysis in human skin. MethodsDialysate was recovered from human skin by 2000 kDa microdialysis membranes from one subject at three different......, albumins, and complement factors, make up the major load of proteins in all three test conditions. ConclusionShotgun proteomics allowed the identification of more than 150 proteins in microdialysis samples from human skin. This highlights the opportunities of LC-MS/MS to study the complex molecular...

  3. Regioisomers of octanoic acid-containing structured triacylglycerols analyzed by tandem mass spectrometry using ammonia negative ion chemical ionization

    DEFF Research Database (Denmark)

    Kurvinen, J.P.; Mu, Huiling; Kallio, H.;

    2001-01-01

    Tandem mass spectrometry based on ammonia negative ion chemical ionization and sample introduction via direct exposure probe was applied to analysis of regioisomeric structures of octanoic acid containing structured triacylglycerols (TAG) of type MML, MLM, MLL, and LML (M, medium-chain fatty acid......; L, long-chain fatty acid). Collision-induced dissociation of deprotonated parent TAG with argon was used to produce daughter ion spectra with appropriate fragmentation patterns for structure determination. Fatty acids constituting the TAG molecule were identified according to [RCO2](-) ions in the...... daughter ion spectra. With the standard curve for ratios of [M - H - RCO2H - 100](-) ions corresponding to each [RCO2](-) ion, determined with known mixtures of sn-1/3 and sn-2 regioisomers of structured TAG, it was possible to determine the proportions of different regioisomers in unknown samples. The...

  4. Analysis of 10 systemic pesticide residues in various baby foods using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Yang, Angel; Abd El-Aty, A M; Park, Jong-Hyouk; Goudah, Ayman; Rahman, Md Musfiqur; Do, Jung-Ah; Choi, Ok-Ja; Shim, Jae-Han

    2014-06-01

    Ten systemic pesticides, comprising methomyl, thiamethoxam, acetamiprid, carbofuran, fosthiazate, metalaxyl, azoxystrobin, diethofencarb, propiconazole, and difenoconazole, were detected in 13 baby foods (cereals, boiled potatoes, fruit and milk) using QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) for sample preparation and liquid chromatography tandem mass spectrometry for analysis. The matrix-matched calibration curves showed good linearity with determination coefficients (R(2) ) >0.992. The limits of detection and quantitation were 0.0015-0.003 and 0.005-0.01 mg/kg, respectively. The mean recoveries of three different concentrations ranged from 69.2 to 127.1% with relative standard deviations pesticide residues. This method is suitable for the identification and quantification of systemic pesticides with matrix-matched standards in various baby foods. PMID:24861738

  5. Determination of Six Pyrazole Fungicides in Grape Wine by Solid-Phase Extraction and Gas Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Shen, Yan; Li, Zhou; Ma, Qiang; Wang, Chuanxian; Chen, Xiangzhun; Miao, Qian; Han, Chao

    2016-05-18

    A gas chromatography-tandem mass spectrometry (GC-MS/MS) method was developed for the first simultaneous identification and quantification of six pyrazole fungicides (furametpyr, rabenzazole, fluxapyroxad, penflufen, bixafen, and isopyrazam) in grape wine samples. The grape wine samples were first diluted with water, then purified by solid-phase extraction, and finally examined by GC-MS/MS in multiple reaction monitoring (MRM) mode. Matrix-matched calibration curves were used to correct the matrix effects. The limits of quantification (LOQs), calculated as 10 times the standard deviation, were 0.2-0.8 μg kg(-1) for the six pyrazole fungicides. The average recoveries were in the range of 74.3-94.5%, with relative standard deviations (RSDs) below 5.8%, measured at three concentration levels. The proposed method is suitable for the simultaneous determination of six pyrazole fungicides in grape wine samples. PMID:27112545

  6. Food safety evaluation: Detection and confirmation of chloramphenicol in milk by high performance liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    A simple and rapid procedure for extraction of chloramphenicol (CAP) in milk and analysis by high-performance liquid chromatography coupled with quadrupole mass spectrometry in tandem was developed. The method consisted of one step of liquid-liquid extraction using ethyl acetate and acidified water (10 mmol L-1 formic acid) and HPLC-MS/MS detection. CAP-D5 was used as internal standard. The method was validated according to Commission Decision 2002/657/EC. The calibration curves were linear, with typical r 2 values higher than 0.98. Absolute recovery of CAP from milk proved to be more than 95%, however CAP-D5 absolute recovery was 75%. The method was accurate and reproducible, being successfully applied to the monitoring of CAP in milk samples obtained from the Brazilian market. Decision limit (CCα) was 0.05 ng mL-1 and detection capability (CCβ) was 0.09 ng mL-1

  7. Multiclass determination of phytochemicals in vegetables and fruits by ultra high performance liquid chromatography coupled to tandem mass spectrometry.

    Science.gov (United States)

    Alarcón-Flores, María Isabel; Romero-González, Roberto; Vidal, José Luis Martínez; Frenich, Antonia Garrido

    2013-11-15

    In this study a simultaneous determination of several classes of phytochemicals (isoflavones, glucosinolates, flavones, flavonols and phenolic acids) in tomato, broccoli, carrot, eggplant and grape has been carried out by ultra high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). Solid-liquid extraction assisted by rotary agitator was utilised, using a mixture of methanol:water (80:20, v/v) as solvent. The analytical procedure was validated in all the matrices, obtaining recoveries ranging from 60% to 120% with repeatability values (expressed as relative standard deviations, RSDs) lower than 25%. Limits of quantification (LOQs) were always equal or lower than 50μg/kg, except for some glucosinolates (125μg/kg). Finally the method was applied to different matrices such as tomato, broccoli, carrot, grape and eggplant, observing that chlorogenic acid was detected in most of the samples at higher concentrations in relation to the other compounds. PMID:23790894

  8. Affinity labeling coupled with matrix assistant laser desorption tandem time of flight mass spectrometry for quantitative proteomies research

    Institute of Scientific and Technical Information of China (English)

    MENG Qingfang; ZHANG Yangjun; CAI Yun; QIAN Xiaohong

    2007-01-01

    A relative quantitative method for differential proteomics by cleavable isotope-coded atTmity tag (cICAT)and matrix-assisted laser desorption/ionization tandem time-of-flight mass spectrometry (MALDI-TOF-MS) was estab-lished. The accuracy and reproducibility of the method were evaluated by bovine serum albumin (BSA) digest as having a relative standard deviation of less than 30% and good reproducibility. The dynamic range was als0 evaluated by analyzing two mixtures of several standard proteins with dif-ferent concentration. The experimental results showed that in the dynamic range of 1:30, the quantitation error of the method was less than 30%. Although the quantitation error becomes very large when used beyond this range, it does not affect the derivation of information on the differential proteins. All the work provides an alternative method for differential proteomics analysis in biological samples from different origins.

  9. Development, validation and determination of multiclass pesticide residues in cocoa beans using gas chromatography and liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Zainudin, Badrul Hisyam; Salleh, Salsazali; Mohamed, Rahmat; Yap, Ken Choy; Muhamad, Halimah

    2015-04-01

    An efficient and rapid method for the analysis of pesticide residues in cocoa beans using gas and liquid chromatography-tandem mass spectrometry was developed, validated and applied to imported and domestic cocoa beans samples collected over 2 years from smallholders and Malaysian ports. The method was based on solvent extraction method and covers 26 pesticides (insecticides, fungicides, and herbicides) of different chemical classes. The recoveries for all pesticides at 10 and 50 μg/kg were in the range of 70-120% with relative standard deviations of less than 20%. Good selectivity and sensitivity were obtained with method limit of quantification of 10 μg/kg. The expanded uncertainty measurements were in the range of 4-25%. Finally, the proposed method was successfully applied for the routine analysis of pesticide residues in cocoa beans via a monitoring study where 10% of them was found positive for chlorpyrifos, ametryn and metalaxyl. PMID:25442595

  10. Quantification of antidepressants and antipsychotics in human serum by precipitation and ultra high pressure liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Hasselstrøm, Jørgen Bo

    2011-01-01

    precipitated with zinc sulphate and methanol containing a stable isotope labelled analog for each analyte. Quantitative analysis was performed by ultra high pressure liquid chromatography combined with a tandem mass spectrometer using a Zorbax SB-C8 column (2.0×50mm; 1.8m) with a mobile phase consisting of 0.......1% formic acid in water and methanol, respectively. The total run time of the chromatography was 4 min. Precision and trueness varied from 2.6% to 14.9% and 87.6% to 103.5%, respectively. At the lower limit of quantification, precision was up to 17.9% and trueness varied from 89.5% to 111.5%. A five point...

  11. Accelerator mass spectrometry of 63Ni using a gas-filled magnet at the Munich Tandem Laboratory

    Science.gov (United States)

    Rugel, G.; Faestermann, T.; Knie, K.; Korschinek, G.; Marchetti, A. A.; McAninch, J. E.; Rühm, W.; Straume, T.; Wallner, C.

    2000-10-01

    The detection of 63Ni ( T1/2=100.1 yr) by means of accelerator mass spectrometry (AMS) using a gas-filled magnet (GFM) is described. The experimental setup includes a dedicated ion source, a 14 MV MP tandem, a GFM and a multi-anode ionization chamber. First results indicate a background level of 63Ni/Ni ratios as low as 2×10 -14. This sensitivity will allow - for the first time ever - to detect 63Ni induced by fast neutrons in copper samples from Hiroshima and Nagasaki, even for distances beyond 1500 m from the hypocenters. Thus, it will be possible to reconstruct experimentally the neutron doses of the A-bomb survivors from Hiroshima and Nagasaki.

  12. Characterisation of honeys according to their content of phenolic compounds using high performance liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Sergiel, Iwona; Pohl, Pawel; Biesaga, Magdalena

    2014-02-15

    A simple, fast and specific high performance liquid chromatography separation with an electro-spray ionisation tandem mass spectrometry detection in a negative single reaction ion monitoring scan mode was developed and used for the characterization of Polish honeys according to the content of phenolic acids, including caffeic, chlorogenic, p-coumaric, ferulic, homogentisic, p-hydroxybenzoic and vanillic acids, and flavonoids, i.e., apigenin, genistein, hesperetin, kaempferol, luteolin, rhamnetin, rutin, tricetin and quercetin. Target compounds were isolated and pre-concentrated from the honey matrix by means of the solid phase extraction using Strata X (500mg) cartridges. Analysed honeys did not contain tricetin and genistein. Hesperetin was determined for the first time in heather and linden honeys while rutin in rape honey. PMID:24128495

  13. INFRARED SPECTRUM OF POTASSIUM-CATIONIZED TRIETHYLPHOSPHATE GENERATED USING TANDEM MASS SPECTROMETRY AND INFRARED MULTIPLE PHOTON DISSOCIATION

    Energy Technology Data Exchange (ETDEWEB)

    Gary S. Groenewold; Christopher M. Leavitt; Ryan P. Dain; Jos Oomens; Jeff Steill; van Stipdonk, Michael J.

    2009-09-01

    Tandem mass spectrometry and wavelength selective infrared photodissociation was used to generate an infrared spectrum of gas-phase triethylphosphate cationized by attachment of K+. Prominent absorptions were observed in the region of 900 to 1300 cm-1 that are characteristic of phosphate P=O and P-O-R stretches. The relative positions and intensities of the IR absorptions were reproduced well by density functional theory (DFT) calculations performed using the B3LYP functional and the 6-31+g(d), 6-311+g(d,p) and 6-311++G(3df,2pd) basis sets. Because of good correspondence between experiment and theory for the cation, DFT was then used to generate a theoretical spectrum for neutral triethylphosphate, which in turn accurately reproduces the IR spectrum of the neat liquid when solvent effects are included in the calculations.

  14. INFRARED SPECTRUM OF POTASSIUM-CATIONIZED TRIETHYLPHOSPHATE GENERATED USING TANDEM MASS SPECTROMETRY AND INFRARED MULTIPLE PHOTON DISSOCIATION

    International Nuclear Information System (INIS)

    Tandem mass spectrometry and wavelength selective infrared photodissociation was used to generate an infrared spectrum of gas-phase triethylphosphate cationized by attachment of K+. Prominent absorptions were observed in the region of 900 to 1300 cm-1 that are characteristic of phosphate P=O and P-O-R stretches. The relative positions and intensities of the IR absorptions were reproduced well by density functional theory (DFT) calculations performed using the B3LYP functional and the 6-31+g(d), 6-311+g(d,p) and 6-311++G(3df,2pd) basis sets. Because of good correspondence between experiment and theory for the cation, DFT was then used to generate a theoretical spectrum for neutral triethylphosphate, which in turn accurately reproduces the IR spectrum of the neat liquid when solvent effects are included in the calculations

  15. Screening of protein kinase inhibitors in natural extracts by capillary electrophoresis combined with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Wang, Tongdan; Zhang, Qianqian; Zhang, Yanmei; Kang, Jingwu

    2014-04-11

    We report a capillary electrophoresis method in conjunction with liquid chromatography-tandem mass spectrometry (LC-MS/MS) for screening of protein kinase inhibitors (PKIs) in natural extracts. Protein kinase A (PKA), substrate 5-carboxyfluorescein-labeled kemptide (CLK) and inhibitor H-89 were employed for the method development and validation. Enzymatic inhibition assay was performed with electrophoretically mediated microanalysis technique. Once the bioactivity of a natural extract was confirmed, an assay-guided isolation and structure elucidation using LC-MS/MS were accomplished to identify the compounds which are responsible for the observed bioactivity. Totally 33 natural extracts were screened with the method, and baicalin in the extract of Radix Scutellariae was identified to be a new PKI of PKA. This result demonstrated the practical applicability of our method in screening of PKIs from natural products. PMID:24630067

  16. [Simultaneous determination of six synthetic sweeteners in food by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Liu, Xiaoxi; Ding, Li; Liu, Jinxia; Zhang, Ying; Huang, Zhiqiang; Wang, Libing; Chen, Bo

    2010-11-01

    A simple and sensitive method for the determination of six synthetic sweeteners (sodium cyclamate, saccharin sodium, acesulfame-K, aspartame, alitame and neotame) in food was developed. The synthetic sweeteners were extracted by methanol-water (1 : 1, v/v). The extract was separated on a C18 column using 0.1% (v/v) formic acid-5 mmol/L ammonium formate/acetonitrile as mobile phase, and then detected by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) using multiple reaction monitoring (MRM) mode. The good linearities (r > 0.998) were achieved for all the analytes over the range of 20-500 microg/L. The recoveries obtained ranged from 81.3% to 106.0% at three spiked concentrations, with the relative standard deviations lower than 11%. The established method has been successfully applied to the determination of synthetic sweeteners in food. PMID:21381416

  17. Determining the Binding Sites of β-Cyclodextrin and Peptides by Electron-Capture Dissociation High Resolution Tandem Mass Spectrometry

    Science.gov (United States)

    Qi, Yulin; Geib, Timon; Volmer, Dietrich A.

    2015-07-01

    Cyclodextrins (CDs) are a group of cyclic oligosaccharides, which readily form inclusion complexes with hydrophobic compounds to increase bioavailability, thus making CDs ideal drug excipients. Recent studies have also shown that CDs exhibit a wide range of protective effects, preventing proteins from aggregation, degradation, and folding. These effects strongly depend on the binding sites on the protein surface. CDs only exhibit weak interactions with amino acids, however; conventional analytical techniques therefore usually fail to reveal the exact location of the binding sites. Moreover, some studies even suggest that CD inclusion complexes are merely electrostatic adducts. Here, electron capture dissociation (ECD) was applied in this proof-of-concept study to examine the exact nature of the CD/peptide complexes, and CD binding sites were unambiguously located for the first time via Fourier-transform ion cyclotron resonance (FTICR) tandem mass spectrometry.

  18. Determination of cholesterol and four phytosterols in foods without derivatization by gas chromatography-tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Yan-Zong Chen

    2015-12-01

    Full Text Available In this study, a method for determination of cholesterol and four phytosterols by gas chromatography coupled with electron impact ionization mode–tandem mass spectrometry without derivatization in general food was developed. The sample was saponified with 7.5% KOH in methanol. After heating on hot plate and reflux for 60 minutes, the saponified portion was extracted with n-hexane/petroleum ether (50:50, v/v. The extracts were evaporated with rotary evaporator and then redissolved with tetrahydrofuran. The tetrahydrofuran layer was transferred into an injection vial and analyzed by gas chromatography on a 30 m VF-5 column. Limit of quantification was 2 mg/kg. Recoveries of cholesterol and four phytosterols from general food were between 91% and 100%.

  19. Modernization of Chinese herbal compound and the high performance liquid chromatography tandem mass spectrometry (HPLC-MS)

    Institute of Scientific and Technical Information of China (English)

    LI Wen-lan; SUN Zhi; DU Juan

    2008-01-01

    Chinese herbal compound is playing an important role on curing human diseases. And it has been a trend that Chinese herbal compound is being used all over the world in 21 century. However, our Chinese herbal compound is facing serious challenge for the lack of canonical system of quality criterion for Chinese herbal compound so it has been a urgent problem to set up the quality control standards and reveal therapeutic basis of Chinese herbal compound. In order to give full play to the advantages of Chinese herbal compound, modern scientific and technological is used to research of Chinese herbal compound, especially the high performance liquid chromatography tandem mass spectrometry(HPLC-MS), because it is high sensitive, rapid, and obtain more information. It is very necessary that HPLC-MS is uesed to elucidate the effective components of basic substances of Chinese Herbal Compound, and endow traditional Chinese medicine with modern scientific connotation.

  20. Development of rapid determination of 18 phthalate esters in edible vegetable oils by gas chromatography tandem mass spectrometry.

    Science.gov (United States)

    Liu, Yinping; Wang, Shuhui; Wang, Li

    2013-02-13

    A simultaneous and fast determination of 18 phthalic acid esters (PAEs) in edible vegetable oils was developed. After solvent extraction, the PAEs in the oil sample were further cleaned up by solid-phase extraction. After concentration, the extract was directly injected into gas chromatography tandem mass spectrometry (GC-MS/MS) in positive-ion electron impact (EI) mode. Method quantification limits of 18 PAEs were between 0.01 and 0.1 mg/kg. Quantitative recoveries ranging from 63.9 to 115.3% were obtained by analysis of spiked oil. The relative standard deviations were less than 15% (n = 6). The method could potentially overcome the interference from large amounts of lipids and pigment. It was applied to real sample and shown to be a rapid and reliable alternative for determination and confirmation of PAEs in routine analysis. PMID:23339279

  1. Accelerator mass spectrometry of 63Ni using a gas-filled magnet at the Munich Tandem Laboratory

    International Nuclear Information System (INIS)

    The detection of 63Ni (T1/2=100.1 yr) by means of accelerator mass spectrometry (AMS) using a gas-filled magnet (GFM) is described. The experimental setup includes a dedicated ion source, a 14 MV MP tandem, a GFM and a multi-anode ionization chamber. First results indicate a background level of 63Ni/Ni ratios as low as 2x10-14. This sensitivity will allow - for the first time ever - to detect 63Ni induced by fast neutrons in copper samples from Hiroshima and Nagasaki, even for distances beyond 1500 m from the hypocenters. Thus, it will be possible to reconstruct experimentally the neutron doses of the A-bomb survivors from Hiroshima and Nagasaki

  2. The use of liquid chromatography tandem mass spectrometry to detect proteins in saliva from horses with and without systemic inflammation.

    Science.gov (United States)

    Jacobsen, Stine; Top Adler, Ditte Marie; Bundgaard, Louise; Sørensen, Mette Aamand; Andersen, Pia Haubro; Bendixen, Emøke

    2014-12-01

    The objective of the study was to assess global expression of proteins in equine saliva using liquid chromatography tandem mass spectrometry (LC-MS/MS). Saliva was obtained from seven horses with and six horses without evidence of systemic inflammatory disease. Tryptic peptides from saliva were analysed by LC-MS/MS. Of 195 unique proteins identified, 57 were detected only in saliva samples from horses with systemic inflammation (in two to six of the seven horses). Among the differentially expressed proteins were several acute phase proteins (APPs) such as serum amyloid A, fibrinogen, haptoglobin, and alpha1-acid glycoprotein. The study is the first to describe detection of inflammatory proteins in horse saliva. The proteins detected were similar to those described in saliva from cattle, small ruminants and pigs. Detection of APPs in horses with systemic inflammation suggests that saliva may be used for non-invasive disease monitoring in horses as in humans, pigs and dogs. PMID:25296850

  3. The use of liquid chromatography tandem mass spectrometry to detect proteins in saliva from horses with and without systemic inflammation

    DEFF Research Database (Denmark)

    Jacobsen, Stine; Top Adler, Ditte Marie; Bundgaard, Louise;

    2014-01-01

    The objective of the study was to assess global expression of proteins in equine saliva using liquid chromatography tandem mass spectrometry (LC-MS/MS). Saliva was obtained from seven horses with and six horses without evidence of systemic inflammatory disease. Tryptic peptides from saliva were...... analysed by LC-MS/MS. Of 195 unique proteins identified, 57 were detected only in saliva samples from horses with systemic inflammation (in two to six of the seven horses). Among the differentially expressed proteins were several acute phase proteins (APPs) such as serum amyloid A, fibrinogen, haptoglobin......, and alpha1-acid glycoprotein. The study is the first to describe detection of inflammatory proteins in horse saliva. The proteins detected were similar to those described in saliva from cattle, small ruminants and pigs. Detection of APPs in horses with systemic inflammation suggests that saliva may be...

  4. Simultaneous quantitation of six major quassinoids in Tongkat Ali dietary supplements by liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Han, Young Min; Jang, Moonhee; Kim, In Sook; Kim, Seung Hyun; Yoo, Hye Hyun

    2015-07-01

    Tongkat Ali (Eurycoma longifolia) is one of the most popular traditional herbs in Southeast Asia and generally consumed as forms of dietary supplements, tea, or drink additives for coffee or energy beverages. In this study, the liquid chromatography with tandem mass spectrometry method for the simultaneous quantitation of six major quassinoids of Tongkat Ali (eurycomanone, 13,21-dihydroeurycomanone, 13α(21)-epoxyeurycomanone, 14,15β-dihydroxyklaineanone, eurycomalactone, and longilactone) was developed and validated. Using the developed method, the content of the six quassinoids was measured in Tongkat Ali containing dietary supplement tablets or capsules, and the resulting data were used to confirm the presence of Tongkat Ali in those products. Among the six quassinoids, eurycomanone was the most abundant quassinoid in all samples tested. The developed method would be useful for the quality assessment of Tongkat Ali containing dietary supplements. PMID:25914245

  5. Simultaneous analysis of buprenorphine, methadone, cocaine, opiates and nicotine metabolites in sweat by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Concheiro, Marta; Shakleya, Diaa M; Huestis, Marilyn A

    2011-04-01

    A liquid chromatography tandem mass spectrometry method for buprenorphine (BUP), norbuprenorphine (NBUP), methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), cocaine, benzoylecgonine, ecgonine methyl ester (EME), morphine, codeine, 6-acetylmorphine, heroin, 6-acetylcodeine, cotinine, and trans-3'-hydroxycotinine quantification in sweat was developed and comprehensively validated. Sweat patches were mixed with 6 mL acetate buffer at pH 4.5, and supernatant extracted with Strata-XC-cartridges. Reverse-phase separation was achieved with a gradient mobile phase of 0.1% formic acid and acetonitrile in 15 min. Quantification was achieved by multiple reaction monitoring of two transitions per compound. The assay was a linear 1-1,000 ng/patch, except EME 5-1,000 ng/patch. Intra-, inter-day and total imprecision were metabolites in sweat patches, with good selectivity and sensitivity. PMID:21125263

  6. Detection and Characterization of Non-covalent Complex between Lappaconitine and β-Cyclodextrin by Electrospray Ionization Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    Qing Xuan XU; Li LI; Hao YUE; Zhi Qiang LIU; Ming Quan GUO; Shu Ying LIU

    2006-01-01

    The non-covalent complexes between lappaconitine (LA) and β-cyclodextrin (β-CD) have been detected and characterized by electrospray ionization combined with ion trap tandem mass spectrometry (ESI-MSn). The experimental results showed that only 1:1 non-covalent complex can be formed in different starting molar ratios of LA to β-CD. Furthermore, the diagnostic fragmentation of the β-CD-LA complex, with a significant contribution of covalent fragmentation of LA leaving the N-acetyl anthranoyl (AN) moiety inserted to β-CD, provided the convincing evidence for the formation of non-covalent complex between LA and β-CD and the cite of LA molecule included to cavity of β-CD assigned to AN residue.

  7. Rapid chiral separation of racemic cetirizine in human plasma using subcritical fluid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Eom, Han Young; Kang, Myunghee; Kang, Seung Woo; Kim, Unyong; Suh, Joon Hyuk; Kim, Junghyun; Cho, Hyun-Deok; Jung, Yura; Yang, Dong-Hyug; Han, Sang Beom

    2016-01-01

    A method for fast chiral separation of cetirizine and quantitation of levocetirizine in human plasma using subcritical fluid chromatography with tandem mass spectrometry was developed and validated. The chromatographic separation was performed using a Chiralpak IE column (2.1 mm×150 mm, 5 μm) with an isocratic elution of CO2/organic modifier (55/45, v/v) at a flow rate of 0.85 mL/min. The organic modifier was composed of water/methanol (5/95, v/v). The makeup flow was optimized at water/methanol (10/90, v/v) and 0.2 mL/min. The most influential parameters on the separation of cetirizine affecting resolution, retention time and sensitivity were selected by fractional factorial design. The 3 selected factors were optimized by response surface methodology. Tandem mass spectrometry was used at electrospray ionization, positive ion mode, and multiple-reaction monitoring mode. Isotope-labeled cetirizine-d4 was used as the internal standard. The sample preparation of human plasma was conducted by solid phase extraction of hydrophilic-lipophilic balance (HLB) type. The developed method was validated for selectivity, linearity, precision, accuracy, recovery, limit of quantitation (LOQ), and limit of detection (LOD). The real human plasma samples were analyzed and the pharmacokinetic results were compared with results of previous research. The developed method was found to be reliable based on the similarity between the results of the current and previous methods. The chiral separation for cetirizine and economic feasibility were compared with those of previous studies using normal phase-HPLC or reversed phase-HPLC. The established analytical method could be successfully applied to pharmacokinetic study with reduction in the analysis time and costs. PMID:26440285

  8. Characterization of polysorbate 85, a nonionic surfactant, by liquid chromatography vs. ion mobility separation coupled with tandem mass spectrometry

    International Nuclear Information System (INIS)

    Graphical abstract: -- Highlights: •Liquid chromatography (LC) separates amphiphilic blends according to hydrophobicity. •Ion mobility (IM) spectrometry separates these blends based on molecular size/shape. •LC–MS provides the separation resolution needed for quantifying fatty acid content. •IM–MS enables rapid, solvent-free separation and the detection of trace components. •With either method, tandem MS allows to count the hydrophobic substituents. -- Abstract: Liquid chromatography (LC) and ion mobility (IM) separation have been coupled with mass spectrometry (MS) and tandem mass spectrometry (MS2) to characterize a commercially important nonionic surfactant, polysorbate 85. The constituents of this amphiphilic blend contained a sorbitan or isosorbide core that was chain extended with poly(ethylene oxide) (PEO) and partially esterified at the PEO termini with oleic acid or, to a lesser extent, other fatty acids. Using interactive LC in reverse-phase mode, the oligomers of the surfactant were separated according to their hydrophobicity/hydrophilicity balance. On the other hand, IM spectrometry dispersed the surfactant oligomers by their charge and collision cross section (i.e. size/shape). With either separation method, an increased number of fatty ester groups and/or lack of the polar sorbitan (or isosorbide) core led to higher retention/drift times, enabling the separation of isobaric species or species with superimposed isotope patterns, so that their ester content could be conclusively identified by MS2. LC–MS and IM–MS permitted the detection of several byproducts besides the major PEO-sorbitan oleate oligomers. LC–MS provides the separation resolution needed for quantitative determination of the degree of esterification. IM–MS, which minimizes analysis time and solvent use, is ideally suitable for a fast, qualitative survey of samples differing in their minor constituents or impurities

  9. Determination of suvorexant in human plasma using 96-well liquid-liquid extraction and HPLC with tandem mass spectrometric detection.

    Science.gov (United States)

    Breidinger, S A; Simpson, R C; Mangin, E; Woolf, E J

    2015-10-01

    A method, using liquid chromatography with tandem mass spectrometric detection (LC-MS/MS), was developed for the determination of suvorexant (MK-4305, Belsomra(®)), a selective dual orexin receptor antagonist for the treatment insomnia, in human plasma over the concentration range of 1-1000ng/mL. Stable isotope labeled (13)C(2)H3-suvorexant was used as an internal standard. The sample preparation procedure utilized liquid-liquid extraction, in the 96-well format, of a 100μL plasma sample with methyl t-butyl ether. The compounds were chromatographed under isocratic conditions on a Waters dC18 (50×2.1mm, 3μm) column with a mobile phase consisting of 30/70 (v/v %) 10mM ammonium formate, pH3/acetonitrile at a flow rate of 0.3mL/min. Multiple reaction monitoring of the precursor-to-product ion pairs for suvorexant (m/z 451→186) and (13)C(2)H3-suvorexant (m/z 455→190) on an Applied Biosystems API 4000 tandem mass spectrometer was used for quantitation. Intraday assay precision, assessed in six different lots of control plasma, was within 10% CV at all concentrations, while assay accuracy ranged from 95.6 to 105.0% of nominal. Quality control (QC) samples in plasma were stored at -20°C. Initial within day analysis of QCs after one freeze-thaw cycle showed accuracy within 9.5% of nominal with precision (CV) of 6.7% or less. The plasma QC samples were demonstrated to be stable for up to 25 months at -20°C. The method described has been used to support clinical studies during Phase I through III of clinical development. PMID:26343269

  10. Characterization of polysorbate 85, a nonionic surfactant, by liquid chromatography vs. ion mobility separation coupled with tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Solak Erdem, Nilüfer; Alawani, Nadrah; Wesdemiotis, Chrys, E-mail: wesdemiotis@uakron.edu

    2014-01-15

    Graphical abstract: -- Highlights: •Liquid chromatography (LC) separates amphiphilic blends according to hydrophobicity. •Ion mobility (IM) spectrometry separates these blends based on molecular size/shape. •LC–MS provides the separation resolution needed for quantifying fatty acid content. •IM–MS enables rapid, solvent-free separation and the detection of trace components. •With either method, tandem MS allows to count the hydrophobic substituents. -- Abstract: Liquid chromatography (LC) and ion mobility (IM) separation have been coupled with mass spectrometry (MS) and tandem mass spectrometry (MS{sup 2}) to characterize a commercially important nonionic surfactant, polysorbate 85. The constituents of this amphiphilic blend contained a sorbitan or isosorbide core that was chain extended with poly(ethylene oxide) (PEO) and partially esterified at the PEO termini with oleic acid or, to a lesser extent, other fatty acids. Using interactive LC in reverse-phase mode, the oligomers of the surfactant were separated according to their hydrophobicity/hydrophilicity balance. On the other hand, IM spectrometry dispersed the surfactant oligomers by their charge and collision cross section (i.e. size/shape). With either separation method, an increased number of fatty ester groups and/or lack of the polar sorbitan (or isosorbide) core led to higher retention/drift times, enabling the separation of isobaric species or species with superimposed isotope patterns, so that their ester content could be conclusively identified by MS{sup 2}. LC–MS and IM–MS permitted the detection of several byproducts besides the major PEO-sorbitan oleate oligomers. LC–MS provides the separation resolution needed for quantitative determination of the degree of esterification. IM–MS, which minimizes analysis time and solvent use, is ideally suitable for a fast, qualitative survey of samples differing in their minor constituents or impurities.

  11. De Novo Correction of Mass Measurement Error in Low Resolution Tandem MS Spectra for Shotgun Proteomics

    Science.gov (United States)

    Egertson, Jarrett D.; Eng, Jimmy K.; Bereman, Michael S.; Hsieh, Edward J.; Merrihew, Gennifer E.; MacCoss, Michael J.

    2012-12-01

    We report an algorithm designed for the calibration of low resolution peptide mass spectra. Our algorithm is implemented in a program called FineTune, which corrects systematic mass measurement error in 1 min, with no input required besides the mass spectra themselves. The mass measurement accuracy for a set of spectra collected on an LTQ-Velos improved 20-fold from -0.1776 ± 0.0010 m/z to 0.0078 ± 0.0006 m/z after calibration (avg ± 95 % confidence interval). The precision in mass measurement was improved due to the correction of non-linear variation in mass measurement accuracy across the m/z range.

  12. Arsenic speciation by liquid chromatography coupled with ionspray tandem mass spectrometry

    DEFF Research Database (Denmark)

    Corr, J. J.; Larsen, Erik Huusfeldt

    1996-01-01

    Ionspray mass spectrometry, a well established organic analysis technique, has been coupled to high-performance liquid chromatography for speciation of organic arsenic compounds, The ionspray source and differentially pumped interface of the mass spectrometer were operated in dual modes for...... fragmentation patterns showing molecular dissociation through an expected common product ion were obtained for the four arsenosugars, Molecular mode detection was utilized for qualitative verification of speciation analysis by high-performance liquid chromatography coupled to inductively coupled plasma mass...

  13. A validated liquid chromatography-tandem mass spectrometry method for the quantitative determination of 4 beta-hydroxycholesterol in human plasma

    NARCIS (Netherlands)

    van de Merbel, Nico C.; Bronsema, Kees J.; van Hout, Mischa W. J.; Nilsson, Ralf; Sillen, Henrik

    2011-01-01

    A novel liquid chromatography-tandem mass spectrometry method is described for the quantitative determination of the endogenous CYP 3A4/5 marker 4 beta-hydroxycholesterol in human K(2)-EDTA plasma. It is based on alkaline hydrolysis to convert esterified to free 4 beta-hydroxycholesterol, followed b

  14. Observation of T-2 and HT-2 glucosides from Fusarium sporotrichioides by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS)

    Science.gov (United States)

    Cultures of Fusarium sporotrichioides were extracted and subjected to evaluation by high performance liquid chromatography – tandem mass spectrometry (LC-MS/MS). Along with the expected T-2 and HT-2 toxins, compounds 162 m/z higher than the toxins were observed. Fragmentation behavior of the larger ...

  15. Comprehensive analysis of B-Lactam antibiotics including penicillins, cephalosporins and carbapenems in poultry muscle using liquid chromatography coupled to tandem mass spectrometry

    NARCIS (Netherlands)

    Berendsen, B.J.A.; Gerritsen, H.W.; Wegh, R.S.; Lameris, S.L.; Sebille, van R.; Stolker, A.A.M.; Nielen, M.W.F.

    2013-01-01

    A comprehensive method for the quantitative residue analysis of trace levels of 22 ß-lactam antibiotics, including penicillins, cephalosporins, and carbapenems, in poultry muscle by liquid chromatography in combination with tandem mass spectrometric detection is reported. The samples analyzed for ß-

  16. Simultaneous quantification of purine and pyrimidine bases, nucleosides and their degradation products in bovine blood plasma by high performance liquid chromatography tandem mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Charlotte Stentoft; Vestergaard, Mogens; Løvendahl, Peter;

    2014-01-01

    ), and their degradation products (uric acid, allantoin, β-alanine, β-ureidopropionic acid, β-aminoisobutyric acid) in blood plasma of dairy cows. The high performance liquid chromatography-based technique coupled to electrospray ionization tandem mass spectrometry (LC–MS/MS) was combined with individual...

  17. A high-performance liquid chromatography-tandem mass spectrometry method for the determination of artemether and dihydroartemisinin in human plasma

    NARCIS (Netherlands)

    Hilhorst, M J; Hendriks, G; de Vries, R; Hillewaert, V; Verhaege, T; van de Merbel, N C

    2014-01-01

    A liquid chromatography-tandem mass spectrometry method is described for the quantitative determination of artemether (ART) and its metabolite dihydroartimisinin (DHA) in human plasma samples. Quantitation of ART and DHA in plasma is challenging due to the presence of malaria related hemolytic produ

  18. Routine approach to qualitatively screen for 300 pesticides and quantify those frequently detected in fruits and vegetables using liquid chromatography tandem mass spectrometry

    Science.gov (United States)

    This paper describes an efficient and effective analytical scheme to first screen for 300 pesticides in fruit and vegetables samples using liquid chromatography tandem mass spectrometry (LC-MS/MS) with a commercial enhanced product ion method. Then, the presumed positive extracts were analyzed using...

  19. Evaluation of low-pressure gas chromatography-tandem mass spectrometry method for analysis of greater than 140 pesticides in fish

    Science.gov (United States)

    A multi-residue method for analysis of 143 pesticide residues in fish was developed and evaluated using fast, low pressure gas chromatography triple quadrupole tandem mass spectrometry (LP-GC/MS-MS). The method was based on a QuEChERS (quick, easy, cheap, effective, rugged, safe) extraction with ace...

  20. Ruggedness testing and validation of a practical analytical method for > 100 veterinary drug residues in bovine muscle by ultrahigh performance liquid chromatography – tandem mass spectrometry

    Science.gov (United States)

    In this study, optimization, extension, and validation of a streamlined, qualitative and quantitative multiclass, multiresidue method was conducted to monitor great than100 veterinary drug residues in meat using ultrahigh-performance liquid chromatography – tandem mass spectrometry (UHPLC-MS/MS). I...

  1. Liquid chromatography with tandem mass spectrometry quantification of urinary proanthocyanin A2 dimer and its potential use as a biomarker of cranberry intake

    Science.gov (United States)

    The lack of a biomarker for the consumption of cranberries has confounded the interpretation of several studies investigating the effect of cranberry products, especially juices, on health outcomes. The objectives of this pilot study were to develop a liquid chromatography tandem mass spectrometric ...

  2. Simultaneous determination of levophencynonate and its metabolite demethyl levophencynonate in human plasma by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Li, Bo; Qi, Wenyuan; Shi, Aixin; Hu, Xin; Cheng, Gang

    2016-08-01

    A sensitive and convenient high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method was developed to determine levophencynonate and demethyl levophencynonate levels in human plasma simultaneously. Chromatographic separation was achieved on a SHIMADZU Shim-Pack XR C8 column and mass spectrometric analysis was performed by an API5000 mass spectrometer coupled with an electro-spray ionization (ESI) source in the positive ion mode. The MRM transitions of m/z 358.4→156.4 and 344.5→144.2 were used to quantify levophencynonate and demethyl levophencynonate, respectively. This analytical method was fully validated with specificity, linearity, lower limit of quantitation (LLOQ), accuracy, precision, stability, matrix effect and recovery. The linearity of this method were developed to be within the concentration ranges of 10-4000pg/mL for levophencynonate and 25-8000pg/mL for demethyl levophencynonate in human plasma. This method was used in a clinical study which was administrated with single oral dose for Chinese healthy subjects to investigate the pharmacokinetics of levophencynonate and demethyl levophencynonate. PMID:27304783

  3. Characterization of botulinum neurotoxin type A subtypes by immunocapture enrichment and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Morineaux, Valérie; Mazuet, Christelle; Hilaire, Didier; Enche, Julien; Popoff, Michel R

    2015-07-01

    Botulinum neurotoxins (BoNT) are divided into seven toxinotypes based on their immunological properties and each toxinotype contains several subtypes according to their amino acid sequences. Here, we designed a mass spectrometry method able to identify BoNT/A subtypes in complex matrices including crude culture supernatants, food, and environmental samples. Peptides from BoNT light chain (L) specific to the subtypes BoNT/A1 to A3 and BoNT/A5 to A8 were identified. The method consists of an immunocapture step with antibodies specific to BoNT/A L chains followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) on a triple quadrupole mass spectrometer (QqQ) in multiple reaction monitoring (MRM) mode. BoNT/A subtypes were correctly identified in culture supernatants and in tap water or orange juice samples with a limit of detection of 20 to 150 mouse lethal doses (MLD) and with a lower sensitivity in serum samples. PMID:26038189

  4. Replacing immunoassays for mephedrone, ketamines and six amphetamine-type stimulants with flow injection analysis tandem mass spectrometry.

    Science.gov (United States)

    Lua, Ingrid A; Lin, Shiou-Ling; Lin, Huei R; Lua, Ahai C

    2012-10-01

    A screening procedure was developed for the simultaneous detection of mephedrone, six amphetamine-type stimulants (ATS), ketamine and its two metabolites with electrospray ionization flow injection analysis tandem mass spectrometry (FIA-MS-MS). Urine samples were fortified with deuterated analogues as internal standards, extracted with ethyl acetate and analyzed with FIA-MS-MS. The mass analyzer was operated in multiple reaction monitoring mode. Two product ions were monitored for each drug and internal standards. For each analyte, the limit of detection was less than 4 µg/L, within-day and between-day precisions (percent coefficient of variation) at three different concentrations were less than 7.3% and bias was between -17.3 and 11.8%. Total analysis time with FIA-MS-MS is 1.8 min per sample. A group of 215 urine samples were screened with immunoassay for ATS and analyzed with FIA-MS-MS and gas chromatography-mass spectrometry (GC-MS) for ketamines and ATS. The analysis of ATS by immunoassay and GC-MS was 96.7% concordant. The analysis of three ketamines and seven ATS by FIA-MS-MS and GC-MS was 97.2% concordant. The FIA-MS-MS procedure is efficient, accurate, flexible and capable of detecting analytes of different chemical groups. It can replace immunoassays for the screening of new designer drugs when commercial immunoassays are unavailable. PMID:22933658

  5. Detection of Sulfur-Fumigated Paeoniae Alba Radix in Complex Preparations by High Performance Liquid Chromatography Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Song-Lin Li

    2012-07-01

    Full Text Available Detection of sulfur-fumigated Paeoniae Alba Radix (PAR in different complex preparations is challenging due to the relatively lower content of PAR and interference from more complicated components in complex preparations with different multiple constituent herbs. In this study, a high performance liquid chromatography- triple-quadrupole tandem mass spectrometry method was developed for detecting sulfur-fumigated PAR in different complex preparations. Paeoniflorin, the major component of PAR, and paeoniflorin sulfonate, the characteristic artifact transformed from paeoniflorin during sulfur-fumigation of PAR, were used as chemical markers. Multiple reaction monitoring (MRM scan was employed to maximize sensitivity and selectivity. Through optimizing full mass scan and daughter ion scan conditions, two mass transitions were selected and employed respectively for unequivocal identification of paeoniflorin and paeoniflorin sulfonate. The detection limits for paeoniflorin and paeoniflorin sulfonate using MRM were much lower than those detected with UV 270 nm. Paeoniflorin and paeoniflorin sulfonate could be simultaneously detected in different commercial PAR-containing complex preparations without interference of other components using the established method, indicating that the newly established method was selective and sensitive enough for screening sulfur-fumigated PAR in commercial complex preparations.

  6. Strategies to in vitro assessment of major human CYP enzyme activities by using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Lahoz, A; Donato, M T; Castell, J V; Gómez-Lechón, M J

    2008-01-01

    At the early stage of drug discovery, thousands of new chemical entities (NCEs) may be screened before a single candidate can be identified for development. Determining the role of CYP enzymes in the metabolism of a compound and evaluating the effect of NCEs on human CYP activities are key issues in pharmaceutical development as they may explain inter-subject variability, drug-drug interactions, non-linear pharmacokinetics and toxic effects. Reliable methods for determining enzyme activities are needed to characterize an individual CYP enzyme and to obtain a tool for the evaluation of its role in drug metabolism in humans. Different liquid chromatography tandem mass spectrometry methodologies have been developed for the fast and routine analysis of major in vivo and in vitro CYPs enzyme activities. The high sensitivity and selectivity of mass spectrometry allow traditional assays to be minimized, thus saving time, efforts and money. Therefore this technology has become the method of choice for the fast assessment of CYP enzyme activities in early drug discovery development. Our intention herein is to review the most recent approaches that have been developed to quickly assess CYPs activities using in vitro models and liquid chromatography coupled with mass spectrometry, as well as their application in early drug discovery. PMID:18220567

  7. Identification of cephapirin metabolites and degradants in bovine milk by electrospray ionization--ion trap tandem mass spectrometry.

    Science.gov (United States)

    Heller, D N; Kaplan, D A; Rummel, N G; von Bredow, J

    2000-12-01

    Liquid chromatography-ion trap tandem mass spectrometry (LC-MS/MS) with electrospray ionization was used to identify cephapirin metabolites and degradants in milk from cows dosed with cephapirin. The milk was extracted according to a previously published procedure. Structures for various components were tentatively identified by their molecular weight, product ion mass spectra, and/or correspondence to standard mass spectra. These components may have occurred as metabolites or as degradants that occurred on storage or during extraction. Compounds identified in the milk included cephapirin, desacetylcephapirin, cephapirin lactone, hydrolyzed cephapirin, and a reduced cephapirin lactone that has not previously been reported. Methylcephapirin was also identified, possibly as a trace contaminant in the formulation. Analysis of incurred milk extracts showed that cephapirin and desacetylcephapirin are the major residues in milk. Desacetylcephapirin residues persisted about as long as the parent drug. The detection limit for both residues by LC-MS/MS was approximately 1 ng/mL in milk. These results have implications for microbiological methods or rapid test kits, if such methods or kits respond to cephapirin metabolites and degradants present in the milk. PMID:11141270

  8. Arsenic speciation by liquid chromatography coupled with ionspray tandem mass spectrometry

    DEFF Research Database (Denmark)

    Corr, J. J.; Larsen, Erik Huusfeldt

    1996-01-01

    Ionspray mass spectrometry, a well established organic analysis technique, has been coupled to high-performance liquid chromatography for speciation of organic arsenic compounds, The ionspray source and differentially pumped interface of the mass spectrometer were operated in dual modes for...

  9. Quantitative determination of multi markers in five varieties of Withania somnifera using ultra-high performance liquid chromatography with hybrid triple quadrupole linear ion trap mass spectrometer combined with multivariate analysis: Application to pharmaceutical dosage forms.

    Science.gov (United States)

    Chandra, Preeti; Kannujia, Rekha; Saxena, Ankita; Srivastava, Mukesh; Bahadur, Lal; Pal, Mahesh; Singh, Bhim Pratap; Kumar Ojha, Sanjeev; Kumar, Brijesh

    2016-09-10

    An ultra-high performance liquid chromatography electrospray ionization tandem mass spectrometry method has been developed and validated for simultaneous quantification of six major bioactive compounds in five varieties of Withania somnifera in various plant parts (leaf, stem and root). The analysis was accomplished on Waters ACQUITY UPLC BEH C18 column with linear gradient elution of water/formic acid (0.1%) and acetonitrile at a flow rate of 0.3mLmin(-1). The proposed method was validated with acceptable linearity (r(2), 0.9989-0.9998), precision (RSD, 0.16-2.01%), stability (RSD, 1.04-1.62%) and recovery (RSD ≤2.45%), under optimum conditions. The method was also successfully applied for the simultaneous determination of six marker compounds in twenty-six marketed formulations. Hierarchical cluster analysis and principal component analysis were applied to discriminate these twenty-six batches based on characteristics of the bioactive compounds. The results indicated that this method is advance, rapid, sensitive and suitable to reveal the quality of Withania somnifera and also capable of performing quality evaluation of polyherbal formulations having similar markers/raw herbs. PMID:27475405

  10. Assessment of Feasibility of Maillard Reaction between Baclofen and Lactose by Liquid Chromatography and Tandem Mass Spectrometry, Application to Pre Formulation Studies

    OpenAIRE

    Monajjemzadeh, Farnaz; Hassanzadeh, Davoud; Valizadeh, Hadi; Siahi-Shadbad, Mohammad R.; Mojarrad, Javid Shahbazi; Robertson, Thomas; Roberts, Michael S

    2009-01-01

    The aim of this study was to determine any possible, baclofen–lactose Maillard reaction products. Granules and tablets of baclofen and lactose were prepared and maintained in heat ovens for a certain time period. The effects of lactose type, addition of magnesium stearate, and water were monitored. Heated lactose and baclofen were analyzed using reverse-phase HPLC. Liquid chromatography tandem mass spectroscopy revealed nominal mass values consistent with baclofen–lactose, early-stage Maillar...

  11. Applying 'Sequential Windowed Acquisition of All Theoretical Fragment Ion Mass Spectra' (SWATH) for systematic toxicological analysis with liquid chromatography-high-resolution tandem mass spectrometry.

    Science.gov (United States)

    Arnhard, Kathrin; Gottschall, Anna; Pitterl, Florian; Oberacher, Herbert

    2015-01-01

    Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has become an indispensable analytical technique in clinical and forensic toxicology for detection and identification of potentially toxic or harmful compounds. Particularly, non-target LC-MS/MS assays enable extensive and universal screening requested in systematic toxicological analysis. An integral part of the identification process is the generation of information-rich product ion spectra which can be searched against libraries of reference mass spectra. Usually, 'data-dependent acquisition' (DDA) strategies are applied for automated data acquisition. In this study, the 'data-independent acquisition' (DIA) method 'Sequential Windowed Acquisition of All Theoretical Fragment Ion Mass Spectra' (SWATH) was combined with LC-MS/MS on a quadrupole-quadrupole-time-of-flight (QqTOF) instrument for acquiring informative high-resolution tandem mass spectra. SWATH performs data-independent fragmentation of all precursor ions entering the mass spectrometer in 21m/z isolation windows. The whole m/z range of interest is covered by continuous stepping of the isolation window. This allows numerous repeat analyses of each window during the elution of a single chromatographic peak and results in a complete fragment ion map of the sample. Compounds and samples typically encountered in forensic casework were used to assess performance characteristics of LC-MS/MS with SWATH. Our experiments clearly revealed that SWATH is a sensitive and specific identification technique. SWATH is capable of identifying more compounds at lower concentration levels than DDA does. The dynamic range of SWATH was estimated to be three orders of magnitude. Furthermore, the >600,000 SWATH spectra matched led to only 408 incorrect calls (false positive rate = 0.06 %). Deconvolution of generated ion maps was found to be essential for unravelling the full identification power of LC-MS/MS with SWATH. With the available software, however, only semi

  12. Tandem anion and cation exchange solid phase extraction for the enrichment of micropollutants and their transformation products from ozonation in a wastewater treatment plant.

    Science.gov (United States)

    Deeb, Ahmad A; Schmidt, Torsten C

    2016-06-01

    The presence of organic micropollutants and their transformation products (TPs) from biotic and abiotic processes in aquatic environments is receiving intense public and scientific attention. Yet a suitable sample preparation method that would enable extraction and enrichment of a wide range of such compounds from water is missing. The focus of this paper was to develop an enhanced solid phase extraction (SPE) protocol which enabled isolation of parent compounds and low molecular weight transformation products (that are produced after treatment of water with ozone) from different water matrices. Ten SPE sorbents were evaluated with regard to their ability to extract acidic, neutral, and basic compounds from water at several pH values. Highest recoveries (91-99 %) for all analytes in pure water were obtained by combining strong anion and cation exchangers of two manufacturers in a tandem mode without pH adjustment. Tandem Oasis (MAX+MCX) was finally applied to extract the spiked analytes from tap water, surface water, and several wastewater samples. The efficiency of the used SPE procedure was examined using an optimized liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method using multiple reaction monitoring (MRM) mode. The occurrence of some of the investigated TPs in environmental water matrices was proven for the first time in this study. Method quantification limits (MQLs) for all compounds ranged from 3.7 to 15.3 ng/L in all matrices. Recoveries (%RE) were between 90 and 110 %. Intraday and interday precision, expressed as relative standard deviation, varied from 0.7 to 5.9 % and 1.8 to 10.3 %, respectively. Matrix effect (%ME) evaluation demonstrated that even complex sample matrices did not show significant ion suppression or enhancement. The applicability of the method was shown during two sampling campaigns at Ruhr river and a wastewater treatment plant (WWTP) equipped with an ozonation step after regular

  13. Qualitative and quantitative analysis of glucosinolates and nucleosides in Radix Isatidis by HPLC and liquid chromatography tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Xiuming Wang

    2013-09-01

    Full Text Available Multi-component fingerprinting and quantitation of the glucosinolates and nucleosides in samples of Radix Isatidis have been carried out using high-performance liquid chromatography with diode-array detection and electrospray ionization tandem mass spectrometry (HPLC–DAD–ESI/MS. Five nucleosides together with one glucosinolate were identified by comparing retention times, ultraviolet spectra, mass spectra and/or empirical molecular formulae of reference compounds. Quantitation of these six compounds was carried out simultaneously by HPLC on a Phenomenex Luna C18 column using gradient elution with methanol and water and detection at 254 nm. All calibration curves were linear (r>0.9994 within test ranges. Limits of detection and quantitation were 0.33 ng and 2.50 ng on column, respectively. Intra- and inter-day precision (as relative standard deviation for all analytes was <2.19% with recoveries in the range 99.6%–101.8% at three concentration levels. The validated method was successfully applied to fingerprinting and assay of 25 batches of Radix Isatidis sourced from different geographical regions of China. The method is simple and reliable and has potential value in the quality control of Radix Isatidis.

  14. Direct determination of glyphosate, glufosinate, and AMPA in soybean and corn by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Chamkasem, Narong; Harmon, Tiffany

    2016-07-01

    Glyphosate, glufosinate, and aminomethylphosphonic acid (AMPA) are amphoteric, low mass, high water soluble, and do not have chromophore. They are very difficult to be retained on a reversed phase HPLC and detected by UV or fluorescence detectors. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed to determine these analytes in soybean and corn using a reversed phase with weak anion-exchange and cation-exchange mixed-mode Acclaim™ Trinity™ Q1 column. The sample was shaken with water containing ethylenediaminetetraacetic acid disodium salt (Na2EDTA) and acetic acid for 10 min to precipitate protein and extract the analytes into the solution. The supernatant was passed thru an Oasis HLB SPE to retain suspended particulates and non-polar interferences. The sample was directly injected and analyzed in 6 min by LC-MS/MS with no sample concentration or derivatization steps. Three isotopically labeled internal standards corresponding to each analyte were used to counter matrix suppression effect. Linearity of the detector response with a minimum coefficient of determination (R (2)) of more than 0.995 was demonstrated in the range of 10 to 1000 ng/mL for each analyte. Accuracy (recovery %) and precision (relative standard deviation or RSD %) were evaluated at the fortification levels of 0.1, 0.5, and 2 μg/g in seven replicates in both soybean and corn samples. PMID:27150204

  15. Determination of platycodin D and platycodin D3 in rat plasma using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kim, Tae-Hyun; Lee, Byung Eui; Kim, Eun Joo; Choi, Yong Seok; Lee, Keun-Sung; Kim, Hak Rim; Kim, Hyung-Gun

    2014-01-01

    Platycodon grandiflorum has long been used as a traditional oriental medicine for respiratory disorder. Platycodin D (PD) is known as the main component isolated from the root of PG. A simple and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the quantitation of PD in rat plasma. Quantitation was performed on a triple quadrupole mass spectrometer employing electrospray ionization and multiple reaction monitoring in positive ion mode. The total chromatographic run time was 4.0 min, and the calibration curves of PD were linear over the concentration range of 50-10,000 ng/mL in rat plasma. The coefficient of variation and relative error at five QC levels were 1.0 to 8.8% and 0.7 to 8.7%, respectively. After a single oral administration of 500 mg/kg and a single intravenous administration of 25 mg/kg of 3% PD extract (a PG extract including 3% of PD), platycodin D and platycodin D3 were detected and pharmacokinetic parameters were estimated. The oral bioavailability of platycodin D and platycodin D3 was 0.29% and 1.35% in rats at 500 mg/kg of 3% PD extract of PG, respectively. The present method can be applied to pharmacokinetic analysis of platycodins and platycosides of the PG. PMID:24592150

  16. Simultaneous determination of six phenolic constituents of danshen in human serum using liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Li, Xiaochuan; Yu, Chen; Cai, Yongbao; Liu, Gangyi; Jia, Jingying; Wang, Yiping

    2005-06-01

    The six phenolic constituents are water-soluble components extracted from the Chinese medical herb danshen, the dried roots of Salvia miltiorrhiza Bunge (Labiatae). An liquid chromatography/tandem mass spectrometry (LC/MS/MS)-based method has been developed for the simultaneous quantification of six phenolic constituents of danshen (magnesium lithospermate B (MLB), rosmarinic acid (RA) and lithospermic acid (LA), caffeic acid (CAA), protocatechuic aldehyde (3,4-dihydroxybenzaldehyde, Pal), 3,4-dihydroxyphenyllactic acid (danshensu)) in human serum with chloramphenicol as internal standard. The serum samples were treated by special liquid-liquid extraction, and the analytes were determined using electrospray negative ionization mass spectrometry in the multiple reaction monitoring (MRM) mode, with sufficient sensitivity to allow analysis of human serum samples generated following administration of a clinically relevant dose. Good linearity over the range 8-2048 ng/mL for six phenolic constituents was observed. The intra- and inter-day precisions (CV) of analysis were <13%, and the accuracy ranged from 88 to 116%. This quantitation method was successfully applied to a pharmacokinetic study of i.v. drip infusion of Danshen injection fluid in human. PMID:15866491

  17. Successful adaption of a forensic toxicological screening workflow employing nontargeted liquid chromatography-tandem mass spectrometry to water analysis.

    Science.gov (United States)

    Steger, Julia; Arnhard, Kathrin; Haslacher, Sandra; Geiger, Klemens; Singer, Klaus; Schlapp, Michael; Pitterl, Florian; Oberacher, Herbert

    2016-04-01

    Forensic toxicology and environmental water analysis share the common interest and responsibility in ensuring comprehensive and reliable confirmation of drugs and pharmaceutical compounds in samples analyzed. Dealing with similar analytes, detection and identification techniques should be exchangeable between scientific disciplines. Herein, we demonstrate the successful adaption of a forensic toxicological screening workflow employing nontargeted LC/MS/MS under data-dependent acquisition control and subsequent database search to water analysis. The main modification involved processing of an increased sample volume with SPE (500 mL vs. 1-10 mL) to reach LODs in the low ng/L range. Tandem mass spectra acquired with a qTOF instrument were submitted to database search. The targeted data mining strategy was found to be sensitive and specific; automated search produced hardly any false results. To demonstrate the applicability of the adapted workflow to complex samples, 14 wastewater effluent samples collected on seven consecutive days at the local wastewater-treatment plant were analyzed. Of the 88,970 fragment ion mass spectra produced, 8.8% of spectra were successfully assigned to one of the 1040 reference compounds included in the database, and this enabled the identification of 51 compounds representing important illegal drugs, members of various pharmaceutical compound classes, and metabolites thereof. PMID:26791338

  18. [Simultaneous determination of dichlorvos, trichlorfon and naled in fruits and vegetables by liquid chromatography with tandem mass spectrometry].

    Science.gov (United States)

    Ibuki, Sachiyo; Uranishi, Katsushige; Uno, Masakiyo

    2007-10-01

    A method for simultaneous determination of Dichlorvos (DDVP), Trichlorfon (DEP) and Naled (BRP) in fruits and vegetables by liquid chromatography with tandem mass spectrometry (LC/MS/MS) was developed. Pesticides were extracted with ethyl acetate together with phosphoric acid and anhydrous sodium sulfate, followed by an ENVI-Carb cartridge cleanup. Phosphoric acid prevented BRP from being converted to DDVP during extraction of pesticides from the sample. When the sample was dissolved in acetonitrile in a silanized glass vial, BRP and DEP remained intact. Mass spectral acquisition was performed with a TurbolonSpray (ESI) interface in the positive mode by applying multiple reaction monitoring. In LC separation, an ODS column was used with acetic acid-ammonium acetate-methanol as a mobile phase. Recoveries from 8 fruits and vegetables at the fortification level of 0.1 microg/g were 75.0-91.8% for BRP, 70.2-88.9% for DDVP, and 77.3-92.1% for DEP. The detection limits of BRP, DDVP and DEP were 1, 2 and 2 ng/g, respectively. PMID:18027546

  19. Paired-ion electrospray ionization--triple quadrupole tandem mass spectrometry for quantification of anionic surfactants in waters.

    Science.gov (United States)

    Santos, Inês C; Guo, Hongyue; Mesquita, Raquel B R; Rangel, António O S S; Armstrong, Daniel W; Schug, Kevin A

    2015-10-01

    A new paired ion electrospray ionization tandem mass spectrometry method for determination of anionic surfactants in water samples was developed. In this method, dicationic ion-pairing reagents were complexed with monoanionic analytes to facilitate analyte detection in positive mode electrospray ionization - mass spectrometry. Single ion monitoring and selected reaction monitoring on a triple quadrupole instrument were performed and compared. Four dicationic reagents were tested for the determination of perfluorooctanoic acid (PFOA), perfluorooctane sulfonate (PFOS), sodium dodecyl sulfate (SDS), dodecylbenzene sulfonic acid (DBS), and stearic acid (SA), among other common anions. The obtained limits of detection were compared with those from previous literature. Solid phase extraction using a C18 cartridge was performed in order to eliminate matrix interferences. A literature review was compiled for the methods published between 2010 and 2015 for determination of anionic surfactants. The optimized method was more sensitive than previously developed methods with LOD values of 2.35, 35.4, 37.0, 1.68, and 0.675 pg for SDS, SA, DBS, PFOS, and PFOA, respectively. The developed method was effectively applied for the determination of anionic surfactants in different water samples such as bottled drinking water, cooking water, tap water, and wastewater. PMID:26078166

  20. Nontarget analysis of urine by electrospray ionization-high field asymmetric waveform ion mobility-tandem mass spectrometry.

    Science.gov (United States)

    Beach, Daniel G; Gabryelski, Wojciech

    2011-12-01

    Nearly a decade after first commercialization, high field asymmetric waveform ion mobility spectrometry (FAIMS) has yet to find its place in routine chemical analysis. Prototypes have been used to demonstrate the utility of this separation technique combined with mass spectrometry (MS). Unfortunately, first generation commercial FAIMS instruments have gone practically unused by early adopters. Here, we show this to be due to poor ion transmission in the FAIMS-MS source interface. We present simple instrumental modifications and optimization of experimental conditions to achieve good performance from the first generation commercial FAIMS device (the Ionalytics Selectra) coupled to a high resolution Q-TOF-MS. In combination with nanospray ionization, we demonstrate for the first time the nontarget analysis of urine by FAIMS with minimal sample preparation. We show the unique suitability of electrospray ionization (ESI)-FAIMS-MS for identification of low abundance species such as urinary biomarkers of damage of nucleic acids in a complex biological matrix. The elimination of electrospray noise and matrix components by FAIMS and the continuous flow of analytes through FAIMS for accurate and tandem mass analysis produce high quality spectral data suitable for structural identification of unknowns. These characteristics make ESI-FAIMS-MS ideal for nontarget identification, even when compared to high efficiency LC-ESI-MS. PMID:21978137

  1. Fast gas chromatography and negative-ion chemical ionization tandem mass spectrometry for forensic analysis of cannabinoids in whole blood.

    Science.gov (United States)

    Thomas, Aurélien; Widmer, Christèle; Hopfgartner, Gérard; Staub, Christian

    2007-11-01

    The present work describes a fast gas chromatography/negative-ion chemical ionization tandem mass spectrometric assay (Fast GC/NICI-MS/MS) for analysis of tetrahydrocannabinol (THC), 11-hydroxy-tetrahydrocannabinol (THC-OH) and 11-nor-9-carboxy-tetrahydrocannabinol (THC-COOH) in whole blood. The cannabinoids were extracted from 500 microL of whole blood by a simple liquid-liquid extraction (LLE) and then derivatized by using trifluoroacetic anhydride (TFAA) and hexafluoro-2-propanol (HFIP) as fluorinated agents. Mass spectrometric detection of the analytes was performed in the selected reaction-monitoring mode on a triple quadrupole instrument after negative-ion chemical ionization. The assay was found to be linear in the concentration range of 0.5-20 ng/mL for THC and THC-OH, and of 2.5-100 ng/mL for THC-COOH. Repeatability and intermediate precision were found less than 12% for all concentrations tested. Under standard chromatographic conditions, the run cycle time would have been 15 min. By using fast conditions of separation, the assay analysis time has been reduced to 5 min, without compromising the chromatographic resolution. Finally, a simple approach for estimating the uncertainty measurement is presented. PMID:17913432

  2. Simultaneous determination of ten underivatized biogenic amines in meat by liquid chromatography-tandem mass spectrometry (HPLC-MS/MS).

    Science.gov (United States)

    Sirocchi, Veronica; Caprioli, Giovanni; Ricciutelli, Massimo; Vittori, Sauro; Sagratini, Gianni

    2014-09-01

    Biogenic amines (BAs) are considered to be important indicators of freshness and quality in food. In this work, an analytical method for analyzing ten underivatized BAs in meat by performance liquid chromatography-tandem mass spectrometry has been developed. Comparison between ion trap and triple quadrupole as mass analyzers indicated that the latter provides greater sensitivity and selectivity. The range of the correlation coefficients of the calibration curves of the analyzed compounds was 0.987-0.999, and the limits of detection and limits of quantification were in the range of 0.002-0.1 mg l(-1) and 0.008-0.5 mg l(-1), respectively. Once validated, the method was used to analyze the concentrations of BAs in 16 commercial meat samples, for evaluating the freshness of food through the study of BA indices, i.e. biogenic amine index (BAI) and the ratio spermidine/spermine (SPD/SPE). The results indicated that all the samples were fresh, with a BAI lower than 1.49 mg kg(-1) and a SPD/SPE ratio lower than 0.41 in each case. This methodology for testing the freshness of meat has potential for quality control applications along the entire production chain of meat products. PMID:25230178

  3. Determination of cyclovirobuxine D in human plasma by liquid chromatography tandem mass spectrometry and application in a pharmacokinetic study

    Directory of Open Access Journals (Sweden)

    Ling-li Mu

    2011-10-01

    Full Text Available A sensitive and reliable method based on liquid chromatography tandem mass spectrometry (LC–MS/MS for the quantitation of cyclovirobuxine D in human plasma has been developed and validated. Sample preparation by solid phase extraction was followed by separation on a CN column with a mobile phase of methanol–water (95:5, v/v containing 0.2% formic acid. Mass spectrometric detection in the positive ion mode was carried out by selected reaction monitoring (SRM of the transitions at m/z 403.0→372.0 for cyclovirobuxine D and m/z 325.0→234.0 for citalopram (internal standard. The method was linear in the range 10–200 ng/L with LLOQ of 10 ng/L, recovery >85%, and no significant matrix effects. Intra- and inter-day precisions were all <9% with accuracies of 94.0–104.8%. The method was successfully applied to a pharmacokinetic study involving a single oral administration of a 2 mg cyclovirobuxine D tablet to twenty-two healthy Chinese volunteers.

  4. Determination of aminoglycosides in honey by capillary electrophoresis tandem mass spectrometry and extraction with molecularly imprinted polymers.

    Science.gov (United States)

    Moreno-González, David; Lara, Francisco J; Jurgovská, Nikola; Gámiz-Gracia, Laura; García-Campaña, Ana M

    2015-09-01

    A new analytical method based on capillary zone electrophoresis-tandem mass spectrometry is proposed and validated for the identification and simultaneous quantification of nine aminoglycosides in honey samples. Detection using an ion trap mass analyzer operating in the multiple reaction monitoring mode was used. Different parameters were optimized in order to obtain an adequate separation combined with the highest sensitivity. In order to achieve high selectivity in the sample treatment, a commercially-available molecularly imprinted polymer has been used for the solid phase extraction of the analytes. Under optimum conditions, recoveries for fortified samples ranged from 88.2 to 99.8%, with relative standard deviations lower than 8%. The limits of detection ranged from 0.4 to 28.5 μg kg(-1). Furthermore, the decision limit and the detection capability were evaluated, ranging from 3.5 to 60.5 μg kg(-1) and from 6.0 to 103.1 μg kg(-1), respectively, demonstrating the sensitivity and applicability of this fast and simple method. PMID:26388393

  5. Determination of Platycodin D and Platycodin D3 in Rat Plasma Using Liquid Chromatography-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Tae-Hyun Kim

    2014-01-01

    Full Text Available Platycodon grandiflorum has long been used as a traditional oriental medicine for respiratory disorder. Platycodin D (PD is known as the main component isolated from the root of PG. A simple and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS method has been developed and validated for the quantitation of PD in rat plasma. Quantitation was performed on a triple quadrupole mass spectrometer employing electrospray ionization and multiple reaction monitoring in positive ion mode. The total chromatographic run time was 4.0 min, and the calibration curves of PD were linear over the concentration range of 50–10,000 ng/mL in rat plasma. The coefficient of variation and relative error at five QC levels were 1.0 to 8.8% and 0.7 to 8.7%, respectively. After a single oral administration of 500 mg/kg and a single intravenous administration of 25 mg/kg of 3% PD extract (a PG extract including 3% of PD, platycodin D and platycodin D3 were detected and pharmacokinetic parameters were estimated. The oral bioavailability of platycodin D and platycodin D3 was 0.29% and 1.35% in rats at 500 mg/kg of 3% PD extract of PG, respectively. The present method can be applied to pharmacokinetic analysis of platycodins and platycosides of the PG.

  6. Liquid Chromatography with Tandem Mass Spectrometry: A Sensitive Method for the Determination of Dehydrodiisoeugenol in Rat Cerebral Nuclei

    Directory of Open Access Journals (Sweden)

    You-Bo Zhang

    2016-03-01

    Full Text Available A new liquid chromatography–tandem mass spectrometry (LC-MS/MS method is developed for the quantification of dehydrodiisoeugenol (DDIE in rat cerebral nuclei after single intravenous administration. DDIE and daidzein (internal standard were separated on a Diamonsil™ ODS C18 column with methanol–water containing 0.1% formic acid (81:19, v/v as a mobile phase. Detection of DDIE was performed on a positive electrospray ionization source using a triple quadrupole mass spectrometer. DDIE and daidzein were monitored at m/z 327.2→188.0 and m/z 255.0→199.2, respectively, in multiple reaction monitoring mode. This method enabled quantification of DDIE in various brain areas, including, cortex, hippocampus, striatum, hypothalamus, cerebellum and brainstem, with high specificity, precision, accuracy, and recovery. The data herein demonstrate that our new LC-MS/MS method is highly sensitive and suitable for monitoring cerebral nuclei distribution of DDIE.

  7. Fast quantification of endogenous carbohydrates in plasma using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry.

    Science.gov (United States)

    Zhu, Bangjie; Liu, Feng; Li, Xituo; Wang, Yan; Gu, Xue; Dai, Jieyu; Wang, Guiming; Cheng, Yu; Yan, Chao

    2015-01-01

    Endogenous carbohydrates in biosamples are frequently highlighted as the most differential metabolites in many metabolomics studies. A simple, fast, simultaneous quantitative method for 16 endogenous carbohydrates in plasma has been developed using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry. In order to quantify 16 endogenous carbohydrates in plasma, various conditions, including columns, chromatographic conditions, mass spectrometry conditions, and plasma preparation methods, were investigated. Different conditions in this quantified analysis were performed and optimized. The reproducibility, precision, recovery, matrix effect, and stability of the method were verified. The results indicated that a methanol/acetonitrile (50:50, v/v) mixture could effectively and reproducibly precipitate rat plasma proteins. Cold organic solvents coupled with vortex for 1 min and incubated at -20°C for 20 min were the most optimal conditions for protein precipitation and extraction. The results, according to the linearity, recovery, precision, matrix effect, and stability, showed that the method was satisfactory in the quantification of endogenous carbohydrates in rat plasma. The quantified analysis of endogenous carbohydrates in rat plasma performed excellently in terms of sensitivity, high throughput, and simple sample preparation, which met the requirement of quantification in specific expanded metabolomic studies after the global metabolic profiling research. PMID:25359182

  8. Butyrolactone I Quantification from Lovastatin Producing Aspergillus terreus Using Tandem Mass Spectrometry—Evidence of Signalling Functions

    Directory of Open Access Journals (Sweden)

    Elina K. Palonen

    2014-06-01

    Full Text Available Aspergillus terreus is an industrially important filamentous fungus producing a wide spectrum of secondary metabolites, including lovastatin and itaconic acid. It also produces butyrolactone I which has shown potential as an antitumour agent. Additionally, butyrolactone I has been implicated to have a regulating role in the secondary metabolism and morphology of A. terreus. In this study, a quantitative time-course liquid chromatography—electrospray ionisation—tandem mass spectrometry (LC-ESI-MS-MS analysis of butyrolactone I is reported for the first time in nine-day long submerged cultures of A. terreus. Butyrolactone I was fragmented in the mass analysis producing a reproducible fragmentation pattern of four main daughter ions (m/z 307, 331, 363 and 393 in all the samples tested. Supplementing the cultures with 100 nM butyrolactone I caused a statistically significant increase (up to two-fold in its production, regardless of the growth stage but was constitutive when butyrolactone I was added at high cell density during the stationary phase. Furthermore, the extracellular butyrolactone I concentration peaked at 48 h post inoculation, showing a similar profile as has been reported for bacterial quorum sensing molecules. Taken together, the results support the idea of butyrolactone I as a quorum sensing molecule in A. terreus.

  9. [Determination of spinosyns A and D residues in food by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Zhang, Jin; Yang, Lizhong; Lin, Liyi; Chen, Luping; Zhou, Yu; Xu, Dunming

    2011-07-01

    A high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/ MS) method was established for the determination of spinosyns A and D residues in foodstuffs. The food samples were extracted with acetonitrile-water (50:50, v/v), and then purified by an HLB solid phase extraction (SPE) column. The analytes were determined by HPLC-MS/MS and quantified by external standard method. The mass spectrometric detection was operated with electrospray in positive ionization mode and the spinosyns A and D were identified in multiple reaction monitoring (MRM) mode. The linear range of the method was 1-20 microg/L, with the correlation coefficient (r2) of 0.999 9. No significant matrix effect was found for spiked samples. The recoveries of spinosyns A and D spiked in food were 76.2%-114.0% at the spiked levels of 1-10 microg/kg. The relative standard deviations (RSDs) were less than 10%. The limits of detection (LODs) and quantification (LOQs) were 0.2 microg/kg and 0.5 microg/kg for spinosyn A, 0.5 microg/kg and 1.0 microg/kg for spinosyn D, respectively. The proposed procedure was applied to the analysis of 969 real samples from Xiamen, Fujian Province (China), of which 15 positive samples were found. The results showed that the proposed method is sensitive and accurate for the determination of spinosyns A and D in foodstuffs. PMID:22097790

  10. [Simultaneous determination of three sulfonamide residues in modified milk by ultra performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Cheng, Guodong; Wu, Xiaohui; Jin, Zhu; Zhang, Yu; Hao, Dan; Tong, Mianhuan; Gao, Jianjun

    2015-08-01

    An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/ MS) method for the residue determination of sulfadiazine, sulfamerazine and sulfamethazine in modified milk was established. The modified milk samples were extracted and their protein precipitated with water (containing 1% (v/v) acetic acid) and methanol. Then they were purified with an HLB solid phase extraction cartridge. The separation was performed on an ACQUITY UPLC HSS T3 column (100 mm x 2.1 mm, 1.8 µm) with a gradient system of water (containing 0.1% (v/v) formic acid) and acetonitrile as mobile phases at a flow rate of 0.3 mL/min, and detected by the MS in ESI+ mode. Standard curves were drawn by using matrix standard addition method, and the external standard method was used for quantitative analysis. The limits of quantification were 1 µg/kg. The calibration curves for the three sulfa drugs were linear in the mass concentration range of 1-100 µg/L with R2 ≥ 0.998. The recoveries at the levels of 1, 2, 10 µg/kg fortified samples ranged from 76.5% to 101.9% with the relative standard deviations of 1.2%-12.4%. The method is simple, rapid, accurate, and its performance can meet the requirements of the domestic and international legislations. It is suitable for the detection of sulfonamide residues in modified milk. PMID:26749868

  11. Black carbon mass size distributions of diesel exhaust and urban aerosols measured using differential mobility analyzer in tandem with Aethalometer

    Science.gov (United States)

    Ning, Zhi; Chan, K. L.; Wong, K. C.; Westerdahl, Dane; Močnik, Griša; Zhou, J. H.; Cheung, C. S.

    2013-12-01

    Black carbon (BC) is the dominant component of the light absorbing aerosols in the atmosphere, changing earth's radiative balance and affecting the climate. The mixing state and size distribution of atmospheric BC are largely unknown and cause uncertainties in climate models. BC is also a major component of diesel PM emissions, recently classified by World Health Organization as Category I Carcinogen, and has been associated with various adverse health effects. This study presents a novel approach of direct and continuous measurement of BC mass size distribution by tandem operation of a differential mobility spectrometry and a refined Aethalometer. A condensation particle counter was deployed in parallel with the Aethalometer to determine particle number size distribution. A wide range of particle sizes (20-600 nm) was investigated to determine the BC modal characteristics in fresh diesel engine tailpipe emissions and in different urban environments including a typical urban ambient site and a busy roadside. The study provided a demonstration of a new analytic approach and showed the evolution of BC mass size distribution from fresh engine emissions to the aged aerosols in the roadside and ambient environments. The results potentially can be used to refine the input for climate modeling to determine the effect of particle-bound atmospheric BC on the global climate.

  12. Molecular Characterization and Tandem Mass Spectrometry of the Lectin Extracted from the Seeds of Dioclea sclerocarpa Ducke

    Directory of Open Access Journals (Sweden)

    Kyria Santiago do Nascimento

    2011-10-01

    Full Text Available Lectin from the seeds of Dioclea sclerocarpa (DSL was purified in a single step by affinity chromatography on a Sephadex G-50 column. The primary sequence, as determined by tandem mass spectrometry, revealed a protein with 237 amino acids and 81% of identity with ConA. DSL has a molecular mass of 25,606 Da. The β and γ chains weigh 12,873 Da and 12,752 Da, respectively. DSL hemagglutinated rabbit erythrocytes (both native and treated with proteolytic enzymes, showing stability even after one hour of exposure to a specific pH range. The hemagglutinating activity of DSL was optimal between pH 6.0 and 8.0, but was inhibited after incubation with D-galactose and D-glucose. The pure protein possesses a molecular mass of 25 kDa by SDS-PAGE and 25,606 Da by mass spectrometry. The secondary structure content was estimated using the software SELCON3. The results indicate that b-sheet secondary structures are predominant in DSL (approximately 42.3% antiparallel b-sheet and 6.7% parallel b-sheet. In addition to the b-sheet, the predicted secondary structure of DSL features 4.1% a-helices, 15.8% turns and 31.3% other contributions. Upon thermal denaturation, evaluated by measuring changes in ellipticity at 218 nm induced by a temperature increase from 20 °C to 98 °C, DSL displayed cooperative sigmoidal behavior with transition midpoint at 84 °C and permitted the observation of two-state model (native and denatured.

  13. Global proteomic profiling of phosphopeptides using electron transfer dissociation tandem mass spectrometry

    DEFF Research Database (Denmark)

    Molina, Henrik; Horn, David M; Tang, Ning; Mathivanan, Suresh; Pandey, Akhilesh

    2007-01-01

    Electron transfer dissociation (ETD) is a recently introduced mass spectrometric technique that provides a more comprehensive coverage of peptide sequences and posttranslational modifications. Here, we evaluated the use of ETD for a global phosphoproteome analysis. In all, we identified a total of...... method for localization of phosphorylation sites and should be an integral component of any strategy for comprehensive phosphorylation analysis....

  14. A quantitative assay for reductive metabolism of a pesticide in fish using electrochemistry coupled with liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Bussy, Ugo; Chung-Davidson, Yu-Wen; Li, Ke; Li, Weiming

    2015-04-01

    This is the first study to use electrochemistry to generate a nitro reduction metabolite as a standard for a liquid chromatography-mass spectrometry-based quantitative assay. This approach is further used to quantify 3-trifluoromethyl-4-nitrophenol (TFM) reductive metabolism. TFM is a widely used pesticide for the population control of sea lamprey (Petromyzon marinus), an invasive species of the Laurentian Great Lakes. Three animal models, sea lamprey, lake sturgeon (Acipenser fulvescens), and rainbow trout (Oncorhynchus mykiss), were selected to evaluate TFM reductive metabolism because they have been known to show differential susceptibilities to TFM toxicity. Amino-TFM (aTFM; 3-trifluoromethyl-4-aminophenol) was the only reductive metabolite identified through liquid chromatography-high-resolution mass spectrometry screening of liver extracts incubated with TFM and was targeted for electrochemical synthesis. After synthesis and purification, aTFM was used to develop a quantitative assay of the reductive metabolism of TFM through liquid chromatography and tandem mass spectrometry. The concentrations of aTFM were measured from TFM-treated cellular fractions, including cytosolic, nuclear, membrane, and mitochondrial protein extracts. Sea lamprey extracts produced the highest concentrations (500 ng/mL) of aTFM. In addition, sea lamprey and sturgeon cytosolic extracts showed concentrations of aTFM substantially higher than those of rainbow trout. However, other fractions of lake sturgeon extracts tend to show aTFM concentrations similar to those of rainbow trout but not with sea lamprey. These data suggest that the level of reductive metabolism of TFM may be associated with the sensitivities of the animals to this particular pesticide. PMID:25730707

  15. Characterization of an Ion Mobility-Multiplexed Collision Induced Dissociation- Tandem Time-of-Flight Mass Spectrometry Approach

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Yehia M.; Prior, David C.; Baker, Erin Shammel; Smith, Richard D.; Belov, Mikhail E.

    2010-06-01

    The confidence in peptide (and protein) identifications with ion mobility spectrometry time-of-flight mass spectrometry (IMS-TOFMS) is expected to drastically improve with the addition of information from an efficient ion dissociation step prior to MS detection. High throughput IMS-TOFMS analysis imposes a strong need for multiplexed ion dissociation approaches where multiple precursor ions yield complex sets of fragment ions that are often intermingled with each other in both the drift time and m/z domains. We have developed and evaluated a novel approach for collision-induced dissociation (CID) with an IMS-TOFMS instrument. It has been shown that precursor ions activated inside an rf-device with an axial dc-electric field produce abundant fragment ions which are radially confined with the rf-field and collisionally cooled at an elevated pressure, resulting in high CID efficiencies comparable or higher than those measured in triple-quadrupole instruments We have also developed an algorithm for deconvoluting these complex multiplexed tandem MS spectra by clustering both the precursor and fragment ions into the matching drift time profiles and by effectively utilizing high mass measurement accuracy of the TOFMS. In a single IMS separation with a tryptic digest of bovine serum albumin (BSA), we have reliably identified 20 unique peptides using multiplexed CID approach downstream of the IMS separation. Peptides were identified based upon the correlation between the precursor and fragment drift time profiles and by matching the profile representative masses to those of in silico BSA tryptic peptides and their fragments. The false discovery rate (FDR) of peptide identifications from multiplexed MS/MS spectra was less than 1%.

  16. Direct analysis by electrospray ionization tandem mass spectrometry of mixtures of phosphatidyldiacylglycerols from Lactobacillus.

    Science.gov (United States)

    Cabrera, G M; Murga, M L; de Valdez, G F; Seldes, A M

    2000-12-01

    Electrospray ionization followed by collision-induced dissociation in a quadrupole ion trap mass spectrometer of mixtures of deprotonated phosphatidyldiacylglycerols afforded a group of three diagnostic ions of convenient abundance for each phosphatidyldiacylglycerol (PG) present in the mixture. Thus, it was possible to determine unmistakably the identity and substitution positions (sn-1 or sn-2) for both acyl groups of each PG present in the mixture. The method also allows the study of isomeric mixtures of PG and mixtures containing minor amounts of some PG from crude extracts of Lactobacillus acidophillus. The present results improve those of previous studies using fast atom bombardment and electrospray ionization tanden mass spectrometry, in which it was reported that it was possible to differentiate the identity and position of the sn-2 acyl substituent only by the presence of one ion, with variable abundance. PMID:11180636

  17. Characterisation of Flavonoid Aglycones by Negative Ion Chip-Based Nanospray Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Paul J. Gates

    2012-01-01

    Full Text Available Flavonoids are one of the most important classes of natural products having a wide variety of biological activities. There is wide interest in a range of medical and dietary applications, and having a rapid, reliable method for structural elucidation is essential. In this study a range of flavonoid standards are investigated by chip-based negative ion nanospray mass spectrometry. It was found that the different classes of flavonoid studied have a combination of distinct neutral losses from the precursor ion [M-H]− along with characteristic low-mass ions. By looking only for this distinct pattern of product ions, it is possible to determine the class of flavonoid directly. This methodology is tested here by the analysis of a green tea extract, where the expected flavonoids were readily identified, along with quercetin, which is shown to be present at only about 2% of the most intense ion in the spectrum.

  18. Characterisation of Flavonoid Aglycones by Negative Ion Chip-Based Nanospray Tandem Mass Spectrometry

    OpenAIRE

    Paul J. Gates; Lopes, Norberto P.

    2012-01-01

    Flavonoids are one of the most important classes of natural products having a wide variety of biological activities. There is wide interest in a range of medical and dietary applications, and having a rapid, reliable method for structural elucidation is essential. In this study a range of flavonoid standards are investigated by chip-based negative ion nanospray mass spectrometry. It was found that the different classes of flavonoid studied have a combination of distinct neutral losses from th...

  19. Performance Characteristics of a New Hybrid Triple Quadrupole Time-of-Flight Tandem Mass Spectrometer

    OpenAIRE

    Andrews, Genna L.; Simons, Brigitte L.; Young, J. Bryce; Hawkridge, Adam M.; David C Muddiman

    2011-01-01

    The TripleTOF 5600 System, a hybrid triple quadrupole time-of-flight mass spectrometer, was evaluated to explore the key figures of merit in generating peptide and protein identifications which included spectral acquisition rates, data quality, proteome coverage, and biological depth. Employing a Saccharomyces cerevisiae tryptic digest, careful consideration of several performance features demonstrated that the speed of the TripleTOF contributed most to the resultant data. The TripleTOF syste...

  20. In silico identification software (ISIS): a machine learning approach to tandem mass spectral identification of lipids

    OpenAIRE

    Kangas, Lars J.; Metz, Thomas O.; Isaac, Giorgis; Schrom, Brian T.; Ginovska-Pangovska, Bojana; Wang, Luning; Tan, Li; Lewis, Robert R.; John H Miller

    2012-01-01

    Motivation: Liquid chromatography–mass spectrometry-based metabolomics has gained importance in the life sciences, yet it is not supported by software tools for high throughput identification of metabolites based on their fragmentation spectra. An algorithm (ISIS: in silico identification software) and its implementation are presented and show great promise in generating in silico spectra of lipids for the purpose of structural identification. Instead of using chemical reaction rate equations...