WorldWideScience

Sample records for chromatography-electrospray tandem mass

  1. Liquid Chromatography-Electrospray Tandem Mass Spectrometry of Terpenoid Lactones in Ginkgo biloba

    OpenAIRE

    Sun, Yongkai; Li, Wenkui; Fitzloff, John F.; van Breemen, Richard B

    2005-01-01

    Ginkgo biloba (ginkgo) is one of most frequently used botanical dietary supplements. The bioactive constituents include the terpenoid lactones consisting of bilobalide and the ginkgolides A, B, C, and J. A new assay based on high performance liquid chromatography-electrospray tandem mass spectrometry (LC-MS-MS) was developed for the measurement of the terpenoid lactones in ginkgo products such as leaf powder and extracts. Initially, the MS-MS fragmentation pathways of ginkgolides were investi...

  2. Quantitative selenium speciation in human urine by using liquid chromatography-electrospray tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lu Ying [University of Crete, Department of Chemistry, Environmental Chemical Processes Laboratory, Voutes Campus, Heraklion 71003, Crete (Greece); Rumpler, Alice; Francesconi, Kevin A. [Institute of Chemistry-Analytical Chemistry, Karl-Franzens University Graz, Graz (Austria); Pergantis, Spiros A., E-mail: spergantis@chemistry.uoc.gr [University of Crete, Department of Chemistry, Environmental Chemical Processes Laboratory, Voutes Campus, Heraklion 71003, Crete (Greece)

    2012-06-20

    Highlights: Black-Right-Pointing-Pointer Development of a selected reaction monitoring mass spectrometric method for the identification of Se species in human urine. Black-Right-Pointing-Pointer A selenosugar was detected as the major human urinary metabolite of selenium in the samples analysed. Black-Right-Pointing-Pointer The trimethylselenonium ion was detected in the urine of one volunteer before and after receiving a selenium supplement. Black-Right-Pointing-Pointer Strict quality control measures were applied to validate identification. Black-Right-Pointing-Pointer Quantitation was conducted using an isotopically labelled internal standard and the standard additions methodology. - Abstract: A liquid chromatography-electrospray-tandem mass spectrometry (ES-MS/MS) method was developed for the speciation analysis of four organic selenium species of relevance to human urinary metabolism, namely trimethylselenomium ion (TMSe{sup +}), selenomethionine (SeMet) and the two selenosugars, methyl 2-acetamido-2-deoxy-1-seleno-{beta}-D-galactos/-glucos-amine (SeGalNAc and SeGluNAc, respectively). Their chromatographic separation was achieved by using a cation exchange pre-column coupled in-series with a reversed-phase high-performance liquid chromatography column, along with an isocratic mobile phase. Online detection was performed using ES-MS/MS in selective reaction monitoring mode. SeGalNAc was detected as the major human urinary metabolite of selenium in the samples analysed, whereas TMSe{sup +} was detected in the urine of one volunteer before and after receiving a selenium supplement. SeMet was not detected as a urine excretory metabolite in this study. Spiking experiments performed with the urine samples revealed significant signal suppression caused by coeluting matrix constituents. To overcome such interferences, isotopically labelled {sup 13}CD{sub 3}{sup 82}SeGalNAc was used as an internal standard, whereas in the absence of an isotopically labelled internal

  3. Characterisation of a proposed internet synthesis of N,N-dimethyltryptamine using liquid chromatography/electrospray ionisation tandem mass spectrometry.

    Science.gov (United States)

    Martins, Cláudia P B; Freeman, Sally; Alder, John F; Brandt, Simon D

    2009-08-14

    The psychoactive properties of N,N-dimethyltryptamine (DMT) are known to induce altered states of consciousness in humans. These properties attract great interest from clinical, neuroscientific, clandestine and forensic communities. The Breath of Hope Synthesis was reported on an internet website as a convenient two-step methodology for the preparation of DMT. The analytical characterisation of the first stage was the subject of previous publications by the authors and involved the thermal decarboxylation of tryptophan and the formation of tryptamine. The present study reports on the characterisation of the second step of this procedure which was based on the methylation of tryptamine. This employed methyl iodide and benzyltriethylammonium chloride/sodium hydroxide as a phase transfer catalyst. The reaction product was characterised by liquid chromatography/electrospray ionisation tandem mass spectrometry and orthogonal acceleration time-of-flight mass spectrometry. Quantitative evaluation was carried out in positive multiple reaction monitoring mode (MRM), which included synthesis of the identified reaction products. MRM screening of the product did not lead to the detection of DMT. Instead, 11.1% tryptamine starting material, 21.0% N,N,N-trimethyltryptammonium iodide (TMT) and 47.4% 1-N-methyl-TMT were detected. A 0.5% trace of the monomethylated N-methyltryptamine was also detected. This study demonstrated the impact on product purity of doubtful synthetic methodologies discussed on the internet. PMID:19592003

  4. Chemical Investigation of Saponins in Different Parts of Panax notoginseng by Pressurized Liquid Extraction and Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry

    OpenAIRE

    Si-Jia Hong; Peng Li; Yi-Tao Wang; Shao-Ping Li; Qing-Wen Zhang; Jian-Bo Wan

    2012-01-01

    A pressurized liquid extraction (PLE) and high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS) method was developed for the qualitative determination of saponins in different parts of P. notoginseng, including rhizome, root, fibre root, seed, stem, leaf and flower. The samples were extracted using PLE. The analysis was achieved on a Zorbax SB-C18 column with gradient elution of acetonitrile and 8 mM aqueous ammonium acet...

  5. Quantification of Docetaxel in Serum Using Turbulent Flow Liquid Chromatography Electrospray Tandem Mass Spectrometry (TFC-HPLC-ESI-MS/MS).

    Science.gov (United States)

    Crutchfield, Christopher A; Marzinke, Mark A; Clarke, William A

    2016-01-01

    Docetaxel is a second-generation taxane and is used clinically as an anti-neoplastic agent in cancer chemotherapy via an anti-mitotic mechanism. Its efficacy is limited to a narrow therapeutic window. Inappropriately high concentrations may cause erythema, fluid retention, nausea, diarrhea, and neutropenia. As a result, dosing recommendations have changed from high dosage loading every 3 weeks to lower dosage loading weekly. We describe a method that can be used for therapeutic drug monitoring of docetaxel levels using turbulent flow liquid chromatography electrospray tandem mass spectrometry (TFC-HPLC-ESI-MS/MS). The method is rapid, requiring only 6.3 min per analytical run following a simple protein crash. The method requires only 100 μL of serum. Concentrations of docetaxel were quantified by a calibration curve relating the peak-area ratio of docetaxel to a deuterated internal standard (docetaxel-D9). The method was linear from 7.8 to 1000 ng/mL, with imprecision ≤6.2 %.

  6. Simultaneous determination of seven bisphenols in environmental water and solid samples by liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Yang, Yunjia; Lu, Libin; Zhang, Jing; Yang, Yi; Wu, Yongning; Shao, Bing

    2014-02-01

    This article presents a simple and universal analytical method for the simultaneous analysis of bisphenol S (BPS), bisphenol F (BPF), bisphenol A (BPA), bisphenol B (BPB), bisphenol AF (BPAF), tetrachlorobisphenol A (TCBPA), and tetrabromobisphenol A (TBBPA) in environmental water (river water, sewage) and solid samples (sediment, sludge) based on liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS). Analytes were extracted from water samples using hydrophilic lipophilic balanced (HLB) solid-phase extraction (SPE) cartridges, and the extracts were further purified using MAX SPE cartridges. For the solid samples, a combination of ultrasonic extraction with the same SPE clean-up procedures used for the water samples was employed. The absolute recoveries for all analytes in the water and solid samples ranged from 57.1 to 114.3%. Good method reproducibility was achieved in terms of intra- and inter-day precision, yielding relative standard deviations (RSDs) less than 16.9 and 18.1%, respectively. The method limits of quantitation (MLOQ) for the seven compounds in environmental water and solid samples ranged from 0.05 to 4.35ng/L and from 0.06 to 2.83ng/g (dry weight, d.w.), respectively. Finally, this method was successfully applied to real environmental sample analysis, which revealed that all of the tested BPs were present, with the exception of BPB.

  7. Determination of benzotriazole corrosion inhibitors from aqueous environmental samples by liquid chromatography-electrospray ionization-tandem mass spectrometry.

    Science.gov (United States)

    Weiss, Stefan; Reemtsma, Thorsten

    2005-11-15

    The first method for the determination of commonly used corrosion inhibitors in environmental water samples by liquid chromatography-electrospray ionization-tandem mass spectrometry is presented. Benzotriazole (BTri) and the two isomers of tolyltriazole (5- and 4-TTri) are separated in an isocratic run. By gradient elution, BTri, 4-TTri, 5-TTri, and xylyltriazole can be determined simultaneously with three benzothiazoles, but here TTri isomers coelute. The instrumental detection limit of 2 pg allows the determination of the three most important benzotriazoles from municipal wastewater and most surface waters by direct injection into the HPLC system without previous enrichment. When solid-phase extraction is employed with mean recovery rates of 95-113%, the limit of quantification for benzotriazoles range from 10 ng/L in groundwater to 25 ng/L in untreated wastewater. BTri and TTri were determined in municipal wastewater in microgram per liter concentrations. Elimination in wastewater treatment appears to be poor, and BTri and TTri can be followed through a water cycle from treated municipal wastewater through surface water to bank filtrate used for drinking water production. The TTri isomers show markedly different biodegradation behavior with 4-TTri being more stable. PMID:16285694

  8. Identification of forced degradation products of tamsulosin using liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Namdev, Deepak; Borkar, Roshan M; Raju, B; Kalariya, Pradipbhai D; Rahangdale, Vinodkumar T; Gananadhamu, S; Srinivas, R

    2014-01-01

    A rapid and gradient high-performance liquid chromatography combined with quadrupole time-of-flight electrospray ionization tandem mass spectrometry (LC/Q-TOF-ESI-MS/MS) method has been developed for the identification and structural characterization of stressed degradation products of tamsulosin. Tamsulosin, a selective α1-adrenoceptor antagonist, was subjected to forced degradation studies under hydrolytic (acid, base and neutral), oxidative, photolytic and thermal stress conditions as per ICH guidelines Q1A (R2). The drug degraded significantly under hydrolytic (base and neutral), thermal, oxidative and photolytic conditions, while it was stable to acid hydrolytic stress conditions. A total of twelve degradation products were formed and the chromatographic separation of the drug and its degradation products were achieved on a GRACE C-18 column (250mm×4.6mm, 5μm). All the degradants have been identified and characterized by LC/ESI-MS/MS and accurate mass measurements. To elucidate the structures of degradation products, fragmentation of the [M+H](+) ions of tamsulosin and its degradation products was studied by using LC-MS/MS experiments combined with accurate mass measurements. The product ions of all the protonated degradation products were compared with the product ions of protonated tamsulosin to assign most probable structures for the observed degradation products. PMID:24083958

  9. Ultra-high performance liquid chromatography-electrospray tandem mass spectrometry for the analysis of antibiotic residues in environmental waters.

    Science.gov (United States)

    Xue, Qiang; Qi, Yanjie; Liu, Fei

    2015-11-01

    An optimized solid-phase extraction (SPE) and ultra-high performance liquid chromatography-electrospray tandem mass spectrometry (UPLC-MS/MS) method was developed for the effective analysis of 35 antibiotics including sulfonamides (SAs), quinolones (QLs), tetracyclines (TCs), macrolides (MALs), lincomycin (LIN), and chloramphenicol (CAP). The addition of 0.1% formic acid to the mobile phase was favorable for the formation of [M + H](+) and the enhancement in the detection signals, but using ammonium formate decreased [M + H](+) with a corresponding reduction in the response of CAP. The optimal pH range for the SPE was 4.5 ∼ 5.0 with 6 mL aqueous ammonia/methanol (5/95, v/v) as the optimized eluent. An internal standard (IS) was selected for each type of analytes based on similarities in classification and retention time. The detection was completed in less than 10 min and was excellent with method detection limits (MDL) of 0.29 ∼ 4.03 ng/L. The recoveries of the antibiotics in samples from ultrapure water and groundwater were 67.13 ∼ 93.00% and 68.91 ∼ 92.67%, respectively. The antibiotics in samples collected from wastewater, surface water, and groundwater were also effectively detected. This newly developed method has the advantages of short detection times, small sample consumption, excellent reproducibility, and high sensitivity. This provides a reliable and promising technique for the simultaneous detection and monitoring of various residual antibiotics in aqueous environmental samples. PMID:26104902

  10. Specific determination of 20 primary aromatic amines in aqueous food simulants by liquid chromatography-electrospray ionization-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Mortensen, Sarah Kelly; Trier, Xenia Thorsager; Foverskov, Annie;

    2005-01-01

    A multi-analyte method without any pre-treatment steps using reversed-phase liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) was developed and applied for the determination of 20 primary aromatic amines (PAA) associated with polyurethane (PUR) products or azo......-colours. The method was validated in-house for water and 3% acetic acid food simulants using spiked migrates from plastic laminates. Detection limits ranged from 0.27 to 3 mu g amine/L food simulants, and RSD values of within-laboratory reproducibility at the 2 mu g PAA/L level ranged from 3.9 to 19%. PAA migration...... of PAA migration from food contact materials....

  11. Development and validation of an ultra high performance liquid chromatography electrospray ionization tandem mass spectrometry method for the simultaneous determination of selected flavonoids in Ginkgo biloba.

    Science.gov (United States)

    Pandey, Renu; Chandra, Preeti; Arya, Kamal Ram; Kumar, Brijesh

    2014-12-01

    A rapid and sensitive ultra high performance liquid chromatography electrospray ionization tandem mass spectrometry method was developed and validated for the simultaneous determination of 13 flavonoids in leaf, stem, and fruit extracts of male and female trees of Ginkgo biloba to investigate gender- and age-related variations of flavonoids content. Chromatographic separation was accomplished on an Acquity UPLC BEH C18 column (50 mm × 2.1 mm id, 1.7 μm) in 5 min. Quantitation was performed using negative electrospray ionization mass spectrometry in multiple reaction monitoring mode. The calibration curves of all analytes showed a good linear relationship (r(2) ≥ 0.9977) over the concentration range of 1-1000 ng/mL. The precision evaluated by an intra- and interday study showed RSD ≤ 1.98% and good accuracy with overall recovery in the range from 97.90 to 101.09% (RSD ≤ 1.67%) for all analytes. The method sensitivity expressed as the limit of quantitation was typically 0.25-3.57 ng/mL. The results showed that the total content of 13 flavonoids was higher in the leaf extract of an old male Ginkgo tree compared to young female Ginkgo trees.

  12. Characterization and identification of iridoid glucosides, flavonoids and anthraquinones in Hedyotis diffusa by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Liu, E-Hu; Zhou, Ting; Li, Guo-Bin; Li, Jing; Huang, Xiu-Ning; Pan, Feng; Gao, Ning

    2012-01-01

    The multiple bioactive constituents in Hedyotis diffusa Willd. (H. diffusa) were extracted and characterized by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC-ESI-MS(n)). The optimized separation condition was obtained using an Agilent ZorBax SB-C18 column (4.6×150 mm, 5 μm) and gradient elution with water (containing 0.1% formic acid) and acetonitrile (containing 0.1% formic acid), under which baseline separation for the majority of compounds was achieved. Among the compounds detected, 14 iridoid glucosides, 10 flavonoids, 7 anthraquinones, 1 coumarin and 1 triterpene were unambiguously identified or tentatively characterized based on their retention times and mass spectra in comparison with the data from standards or references. The fragmentation behavior for different types of constituents was also investigated, which could contribute to the elucidation of these constituents in H. diffusa. The present study reveals that even more iridoid glycosides were found in H. diffusa than hitherto assumed. The occurrence of two iridoid glucosides and five flavonoids in particular has not yet been described. This paper marks the first report on the structural characterization of chemical compounds in H. diffusa by a developed HPLC-ESI-MS(n) method. PMID:25940590

  13. Chemical Investigation of Saponins in Different Parts of Panax notoginseng by Pressurized Liquid Extraction and Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Si-Jia Hong

    2012-05-01

    Full Text Available A pressurized liquid extraction (PLE and high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS method was developed for the qualitative determination of saponins in different parts of P. notoginseng, including rhizome, root, fibre root, seed, stem, leaf and flower. The samples were extracted using PLE. The analysis was achieved on a Zorbax SB-C18 column with gradient elution of acetonitrile and 8 mM aqueous ammonium acetate as mobile phase. The mass spectrometer was operated in the negative ion mode using the electrospray ionization, and a collision induced dissociation (CID experiment was also carried out to aid the identification of compounds. Forty one saponins were identified in different parts of P. notoginseng according to the fragmentation patterns and literature reports, among them, 21 saponins were confirmed by comparing the retention time and ESI-MS data with those of standard compounds. The results showed that the chemical characteristics were obviously diverse in different parts of P. notoginseng, which is helpful for pharmacological evaluation and quality control of P. notoginseng.

  14. Analysis by liquid chromatography-electrospray ionization tandem mass spectrometry and acute toxicity evaluation for beta-blockers and lipid-regulating agents in wastewater samples.

    Science.gov (United States)

    Hernando, M D; Petrovic, M; Fernández-Alba, A R; Barceló, D

    2004-08-13

    This paper describes a multiresidue method for the extraction and determination of two therapeutic groups of pharmaceuticals, lipid-regulating agents (clofibric acid, bezafibrate, gemfibrocil, fenofibrate) and beta-blockers (atenolol, sotalol, metoprolol, betaxolol) in waters by solid-phase extraction followed by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS). Recoveries obtained from spiked HPLC water, as well as, from spiked real samples (sewage treatment plants influent and effluents, river and tap water) were all above 60%, with the exception of betaxolol with a 52% recovery. The quantitative MS analysis was performed using a multiple reaction monitoring. The LC-MS-MS method gave detection limits ranging from 0.017 to 1.25 microg/l in spiked effluent. Precision of the method, calculated as relative standard deviation, ranged from 3.7 to 18.5%. Individual and combined effects on Daphnia magna were evaluated for both therapeutic groups. Individual effects in culture medium showed these compounds as not harmful and not toxic, an exception is fenofibrate that was found to be harmful, but at high, in the environment unrealistic concentrations (EC50 of 50 mg/l). Combined effect in wastewater showed synergistic toxic effects at low concentration level (2 microg/l). PMID:15387181

  15. Analysis of iodinated haloacetic acids in drinking water by reversed-phase liquid chromatography/electrospray ionization/tandem mass spectrometry with large volume direct aqueous injection.

    Science.gov (United States)

    Li, Yongtao; Whitaker, Joshua S; McCarty, Christina L

    2012-07-01

    A large volume direct aqueous injection method was developed for the analysis of iodinated haloacetic acids in drinking water by using reversed-phase liquid chromatography/electrospray ionization/tandem mass spectrometry in the negative ion mode. Both the external and internal standard calibration methods were studied for the analysis of monoiodoacetic acid, chloroiodoacetic acid, bromoiodoacetic acid, and diiodoacetic acid in drinking water. The use of a divert valve technique for the mobile phase solvent delay, along with isotopically labeled analogs used as internal standards, effectively reduced and compensated for the ionization suppression typically caused by coexisting common inorganic anions. Under the optimized method conditions, the mean absolute and relative recoveries resulting from the replicate fortified deionized water and chlorinated drinking water analyses were 83-107% with a relative standard deviation of 0.7-11.7% and 84-111% with a relative standard deviation of 0.8-12.1%, respectively. The method detection limits resulting from the external and internal standard calibrations, based on seven fortified deionized water replicates, were 0.7-2.3 ng/L and 0.5-1.9 ng/L, respectively.

  16. Development of a liquid chromatography-electrospray ionization-tandem mass spectrometry method for the simultaneous analysis of intact glucosinolates and isothiocyanates in Brassicaceae seeds and functional foods.

    Science.gov (United States)

    Franco, P; Spinozzi, S; Pagnotta, E; Lazzeri, L; Ugolini, L; Camborata, C; Roda, A

    2016-01-01

    A new high pressure liquid chromatography-electrospray ionization-tandem mass spectrometry method for the simultaneous determination of glucosinolates, as glucoraphanin and glucoerucin, and the corresponding isothiocyanates, as sulforaphane and erucin, was developed and applied to quantify these compounds in Eruca sativa defatted seed meals and enriched functional foods. The method involved solvent extraction, separation was achieved in gradient mode using water with 0.5% formic acid and acetonitrile with 0.5% formic acid and using a reverse phase C18 column. The electrospray ion source operated in negative and positive mode for the detection of glucosinolates and isothiocyanates, respectively, and the multiple reaction monitoring (MRM) was selected as acquisition mode. The method was validated following the ICH guidelines. Replicate experiments demonstrated a good accuracy (bias%<10%) and precision (CV%<10%). Detection limits and quantification limits are in the range of 1-400ng/mL for each analytes. Calibration curves were validated on concentration ranges from 0.05 to 50μg/mL. The method proved to be suitable for glucosinolates and isothiocyanates determination both in biomasses and in complex matrices such as food products enriched with glucosinolates, or nutraceutical bakery products. In addition, the developed method was applied to the simultaneous determination of glucosinolates and isothiocyanates in bakery product enriched with glucosinolates, to evaluate their thermal stability after different industrial processes from cultivation phases to consumer processing.

  17. Identification of glycerophospholipid molecular species of mussel (Mytilus edulis) lipids by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry.

    Science.gov (United States)

    Yin, Fa-Wen; Zhou, Da-Yong; Zhao, Qi; Liu, Zhong-Yuan; Hu, Xiao-Pei; Liu, Yan-Fei; Song, Liang; Zhou, Xin; Qin, Lei; Zhu, Bei-Wei; Shahidi, Fereidoon

    2016-12-15

    This study was carried out to identify the glycerophosphocholine (GPCho), glycerophosphoethanolamine (GPEtn) and glycerophosphoserine (GPSer) compositions in lipids extracted from mussels using Folch, Bligh-Dyer and methyl-tert-butyl ether (MTBE) methods by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS). The molecular species of GPCho, GPEtn and GPSer were characterized according to the MS and MS/MS information. A semi-quantitative method using internal standard was established to compare the difference in glycerophospholipids (GP) between samples recovered with different methods. At least 212, 230 and 206 GP species were identified, respectively, from lipids recovered by Folch, Bligh-Dyer and MTBE methods. Most of the abundant GP species in mussels contained EPA and DHA. Some GP species with low content were not present in lipids recovered by the Folch and MTBE methods when compared with that recovered by the Bligh-Dyer method. However, for most GP species in lipids recovered by different methods, no quantitative differences existed. PMID:27451190

  18. Liquid Chromatography-electrospray Ionization Tandem Mass Spectrometry for Simultaneous Determination of Metformin and Glimepiride in Beagle Dog Plasma and Bioequivalence Study

    Institute of Scientific and Technical Information of China (English)

    BAI Jing; SHI Xiao-wei; DU Ying-feng; XIANG Bai; WANG Shuai; CAO De-ying

    2012-01-01

    A sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry(LC-ESI-MS/MS) was used for the simultaneous determination of metformin and glimepiride in beagle dog plasma with glipizide as internal standard(IS).After simplified protein precipitation with methanol,both the analytes and IS were chromatographed on a Zorbax CN column via gradient elution with methanol(containing 5 mmol/L ammonium acetate) and 5 mmol/L aqueous ammonium acetate as the mobile phase.Detection was performed by multiple reaction monitoring(MRM) scanning via ESI source operated in positive ionization mode.Specificity,linearity,accuracy,precision,recovery,matrix effect and stability were validated for metformin and glimepiride in beagle dog plasma.The calibration curves were linear in a concentration range of 10--10000 ng/mL for metformin and 4--4000 ng/mL for glimepiride with both correlation coefficients higher than 0.99.The recoveries obtained for the analytes and IS were all between 82.7% and 101.2%.The method exhibited excellent performance in terms of selectivity,robustness,short analytical time and simplicity of sample preparation.Finally,the proposed method was applied to a bioequivalence study of self-made bilayer tablet and commercial formulation containing 500 mg of metformin and 1 mg of glimepiride in beagle dogs.

  19. Simultaneous Determination of Eight Ginsenosides in Rat Plasma by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry: Application to Their Pharmacokinetics.

    Science.gov (United States)

    Ma, Li-Yuan; Zhang, You-Bo; Zhou, Qi-Le; Yang, Yan-Fang; Yang, Xiu-Wei

    2015-01-01

    A high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method was successfully developed and validated for the identification and determination of eight ginsenosides: ginsenoside Rg₁ (1); 20(S)-ginsenoside Rh₁ (2); 20(S)-ginsenoside Rg₂ (3); 20(R)-ginsenoside Rh₁ (4); 20(R)-ginsenoside Rg₂ (5); ginsenoside Rd (6); 20(S)-ginsenoside Rg₃ (7); and 20(R)-ginsenoside Rg₃ (8) in rat plasma. The established rapid method had high linearity, selectivity, sensitivity, accuracy, and precision. The method has been used successfully to study the pharmacokinetics of abovementioned eight ginsenosides for the first time. After an oral administration of total saponins in the stems-leaves of Panax ginseng C. A. Meyer (GTSSL) at a dose of 400 mg/kg, the ginsenosides 6, 7, and 8, belonging to protopanaxadiol-type saponins, exhibited relatively long tmax values, suggesting that they were slowly absorbed, while the ginsenosides 1-5, belonging to protopanaxatriol-type saponins, had different tmax values, which should be due to their differences in the substituted groups. Compounds 2 and 4, 3 and 5, 7 and 8 were three pairs of R/S epimerics at C-20, which was interesting that the t1/2 of 20(S)-epimers were always longer than those of 20(R)-epimers. This pharmacokinetic identification of multiple ginsenosides of GTSSL in rat plasma provides a significant basis for better understanding the clinical application of GTSSL. PMID:26633350

  20. Determination of chlorinated acid herbicides in vegetation and soil by liquid chromatography/electrospray-tandem mass spectrometry.

    Science.gov (United States)

    Schaner, Angela; Konecny, Jaclyn; Luckey, Laura; Hickes, Heidi

    2007-01-01

    The method presented uses reversed-phase liquid chromatography with negative electrospray ionization and tandem mass spectrometry to analyze 9 chlorinated acid herbicides in soil and vegetation matrixes: clopyralid, dicamba, MCPP, MCPA, 2,4-DP, 2,4-D, triclopyr, 2,4-DB, and picloram. A 20 g portion is extracted with a basic solution and an aliquot acidified and micropartitioned with 3 mL chloroform. Vegetation samples are subjected to an additional cleanup with a mixed-mode anion exchange solid-phase extraction cartridge. Two precursor product ion transitions per analyte are measured and evaluated to provide the maximum degree of confidence in results. Average recoveries for 3 different soil types tested ranged from 72 to 107% for all compounds with the exception of 2,4-DB at 56-99%. Average recoveries for the 3 different vegetation types studied were lower and ranged from 53 to 80% for all compounds. PMID:17955986

  1. Characterization of Proanthocyanidins from Parkia biglobosa (Jacq. G. Don. (Fabaceae by Flow Injection Analysis — Electrospray Ionization Ion Trap Tandem Mass Spectrometry and Liquid Chromatography/Electrospray Ionization Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Wagner Vilegas

    2013-03-01

    Full Text Available The present study investigates the chemical composition of the African plant Parkia biglobosa (Fabaceae roots and barks by Liquid Chromatography - Electrospray Ionization and Direct Injection Tandem Mass Spectrometry analysis. Mass spectral data indicated that B-type oligomers are present, namely procyanidins and prodelphinidins, with their gallate and glucuronide derivatives, some of them in different isomeric forms. The analysis evidenced the presence of up to 40 proanthocyanidins, some of which are reported for the first time. In this study, the antiradical activity of extracts of roots and barks from Parkia biglobosa was evaluated using DPPH method and they showed satisfactory activities.

  2. Characterization of proanthocyanidins from Parkia biglobosa (Jacq.) G. Don. (Fabaceae) by Flow Injection Analysis-Electrospray Ionization Ion Trap Tandem Mass Spectrometry and Liquid Chromatography/Electrospray Ionization Mass Spectrometry.

    Science.gov (United States)

    Tala, Viviane Raïssa Sipowo; Candida da Silva, Viviane; Rodrigues, Clenilson Martins; Nkengfack, Augustin Ephrem; dos Santos, Lourdes Campaner; Vilegas, Wagner

    2013-03-01

    The present study investigates the chemical composition of the African plant Parkia biglobosa (Fabaceae) roots and barks by Liquid Chromatography-Electrospray Ionization and Direct Injection Tandem Mass Spectrometry analysis. Mass spectral data indicated that B-type oligomers are present, namely procyanidins and prodelphinidins, with their gallate and glucuronide derivatives, some of them in different isomeric forms. The analysis evidenced the presence of up to 40 proanthocyanidins, some of which are reported for the first time. In this study, the antiradical activity of extracts of roots and barks from Parkia biglobosa was evaluated using DPPH method and they showed satisfactory activities.

  3. Quantification of γ-Aminobutyric Acid in Cerebrospinal Fluid Using Liquid Chromatography-Electrospray Tandem Mass Spectrometry.

    Science.gov (United States)

    Arning, Erland; Bottiglieri, Teodoro

    2016-01-01

    We describe a simple stable isotope dilution method for accurate and precise measurement of γ-aminobutyric acid (GABA), a major inhibitory neurotransmitter in human cerebrospinal fluid (CSF) as a clinical diagnostic test. Determination of GABA in CSF (50 μL) was performed utilizing high performance liquid chromatography coupled with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Analysis of free and total GABA requires two individual sample preparations and mass spectrometry analyses. Free GABA in CSF is determined by a 1:2 dilution with internal standard (GABA-D2) and injected directly onto the HPLC-ESI-MS/MS system. Determination of total GABA in CSF requires additional sample preparation in order to hydrolyze all the bound GABA in the sample to the free form. This requires hydrolyzing the sample by boiling in acidic conditions (hydrochloric acid) for 4 h. The sample is then further diluted 1:10 with a 90 % acetonitrile/0.1 % formic acid solution and injected into the HPLC-ESI-MS/MS system. Each assay is quantified using a five-point standard curve and is linear from 6 nM to 1000 nM and 0.63 μM to 80 μM for free and total GABA, respectively. PMID:26602123

  4. Quantification of Tricyclic Antidepressants in Serum Using Liquid Chromatography Electrospray Tandem Mass Spectrometry (HPLC-ESI-MS/MS).

    Science.gov (United States)

    Crutchfield, Christopher A; Breaud, Autumn R; Clarke, William A

    2016-01-01

    Tricyclic antidepressants (TCA) are used to treat major depressive disorder and other psychological conditions. The efficacy of these drugs is tied to a narrow therapeutic window. Inappropriately high drug concentrations can result in serious side effects such as hypotension, tachycardia, or coma. As a result, concentrations of tricyclic antidepressants are routinely monitored to ensure compliance and to prevent adverse side effects by dose adjustments. We describe a method for the determination of concentrations of amitriptyline, desipramine, imipramine, and nortriptyline in human serum using high-performance liquid chromatography coupled to a tandem mass spectrometer with electrospray ionization (HPLC-ESI-MS/MS). The method is rapid, requiring only 3.5 min per analysis. The method requires 100 μL of serum. Concentrations of each TCA were quantified by a calibration curve relating the peak area ratio of each TCA analyte to a deuterated internal standard (amitriptyline-D3, desipramine-D3, imipramine-D3, and nortriptyline-D3). The method was linear from ~70 ng/mL to ~1000 ng/mL for all TCAs, with imprecision ≤ 12%.

  5. Simultaneous quantitation of atorvastatin and its two active metabolites in human plasma by liquid chromatography/(-) electrospray tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Pankaj Partani; S. Manaswita Verma; Sanjay Gurule; Arshad Khuroo; Tausif Monif

    2014-01-01

    A sensitive, accurate and selective liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed and validated for the simultaneous quantitation of atorvastatin (AT) and its equipotent hydroxyl metabolites, 2-hydroxy atorvastatin (2-AT) and 4-hydroxy atorvastatin (4-AT), in human plasma. Electrospray ionization (ESI) interface in negative ion mode was selected to improve the selectivity and the sensitivity required for this application. Additionally, a solid phase extraction (SPE) step was performed to reduce any ion-suppression and/or enhancement effects. The separation of all compounds was achieved in less than 6 min using a C18 reverse-phase fused-cores column and a mobile phase, composed of a mixture of 0.005%formic acid in water:acetonitrile:methanol (35:25:40, v/v/v), in isocratic mode at a flow rate of 0.6 mL/min. The method has lower limit of quantitation (LLOQ) of 0.050 ng/mL for all analytes. The method has shown tremendous reproducibility, with intra-and inter-day precision less than 6.6%, and intra- and inter-day accuracy within 74.3% of nominal values, for all analytes, and has proved to be highly reliable for the analysis of clinical samples.

  6. Determination of 16 insect growth regulators in edible Chinese traditional herbs by liquid chromatography electrospray tandem mass spectrometry.

    Science.gov (United States)

    Qian, Mingrong; Wu, Liqin; Zhang, Hu; Xu, Mingfei; Li, Rui; Wang, Xiangyun; Sun, Caixia

    2012-03-01

    A new sensitive multiresidue liquid chromatography-tandem mass spectrometry (LC-MS/MS) analytical method for the determination of 16 insect growth regulator (IGR) residues-RH-5849 (1,2-dibenzoyl-1-tert-butylhydrazine), halofenozide, methoxyfenozide, chromafenozide, fufenozide, tebufenozide, diflubenzuron, chlorbenzuron, triflumuron, hexaflumuron, novaluron, lufenuron, teflubenzuron, flucycloxuron, flufenoxuron, and chlorfluazuron-in herbs (Perilla frutescens, flos chrysanthemi, lily bulbs, and ginger) has been developed. After the herbs had been extracted with acetonitrile, a combined graphitized nonporous carbon/aminopropyl (ENVI-Carb/LC-NH(2)) cartridge and a Florisil cartridge were used to clean up the extracts. LC-MS/MS was performed in multiple reaction monitoring mode with two specific precursor ion-product ion transitions per IGR to confirm and quantitate the residues in herbs. Quantitation was performed on the basis of matrix-matched calibrations. The method showed excellent linearity (r(2) > 0.99) and precision (relative standard deviations of 13.6 or lower) for all the target insecticides. The limits of quantitation were 0.6-10 μg kg(-1) for the 16 insecticides in the four herbs. The average recoveries, measured at three concentrations (0.01, 0.1, 1 mg kg(-1)), were in the range 74.8-105.3%. The method was satisfactorily applied for the analysis of 60 herb samples (Perilla frutescens, flos chrysanthemi, lily bulbs, and ginger). Hexaflumuron was detected at concentrations of 0.029 and 0.051 mg kg(-1) in Perilla frutescens. PMID:22271101

  7. [Determination of 49 drugs and 5 metabolites in drinking water samples using ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometry].

    Science.gov (United States)

    Wang, Shuo; Zhang, Xiangming; Zhang, Jing; Shao, Bing; Li, Shuming

    2015-07-01

    A method for the determination of 54 drugs in drinking water samples was developed by using ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometry (UPLC-ESI MS/MS). The target drugs in drinking water samples were enriched and cleaned-up by HLB solid-phase extraction (SPE) cartridges and then eluted with 5 mL methanol. The elute was collected, concentrated under a gentle stream of nitrogen gas, diluted with 0.4 mL 0.1% formic acid solution, and analyzed by UPLC-ESI MS/MS. The separation of the 54 drugs was performed on an ACQUITY UPLC™ BEH C18 column using mobile phases of 0.1% formic acid and methanol by gradient elution. The multiple reaction monitoring (MRM) mode was employed in mass spectrometry acquisition. The matrix-matched external standard calibration was used for quantitation. The results showed that the average recoveries of the drugs in ground water, tap water and surface water were 58.7%-104.4%, 53.1%-109.5%, and 50.7%-118.8%, respectively, and the corresponding relative standard deviations (RSD, n=6) were 0.3%-12.8%, 1.0%-15.5%, and 0.4%-19.3%, respectively. The method quantification limits (MQL) for target compounds were in the range of 0.002-5.000 ng/L. The developed method was applied to analyze the water samples from Beijing. The results showed that 26 drugs were detected in ground water samples.

  8. Quantitation of S-Adenosylmethionine and S-Adenosylhomocysteine in Plasma Using Liquid Chromatography-Electrospray Tandem Mass Spectrometry.

    Science.gov (United States)

    Arning, Erland; Bottiglieri, Teodoro

    2016-01-01

    We describe a simple stable isotope dilution method for accurate determination of S-adenosylmethionine (SAM) and S-adenosylhomocysteine (SAH) in plasma as a diagnostic test. SAM and SAH are key metabolic intermediates of methionine metabolism and the methylation cycle. Determination of SAM and SAH in plasma was performed by high performance liquid chromatography coupled with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Calibrators (SAM and SAH) and internal standards ((2)H3-SAM and (2)H4-SAH) were included in each analytical run for calibration. Sample preparation involved combining 20 μL sample with 180 μL of internal standard solution consisting of heavy isotope labeled internal standards in mobile phase A and filtering by ultracentrifugation through a 10 kd MW cutoff membrane. Sample filtrate (3 μL) was injected by a Shimadzu Nexera LC System interfaced with a 5500 QTRAP(®) (AB Sciex). Chromatographic separation was achieved on a 250 mm × 2.0 mm EA:faast column from Phenomenex. Samples were eluted at a flow rate of 0.20 mL/min with a binary gradient with a total run time of 10 min. The source operated in positive ion mode at an ion spray voltage of +5000 V. SAM and SAH resolved by a gradient to 100 % methanol with retention times of 6.0 and 5.7 min, respectively. The observed m/z values of the fragment ions were m/z 399 → 250 for SAM, m/z 385 → 136 for SAH, m/z 402 → 250 for (2)H3-SAM, m/z 203 → 46. The calibration curve was linear over the ranges of 12.5-5000 nmol/L for SAM and SAH. PMID:26602137

  9. Analysis of advanced glycation endproducts in dairy products by isotope dilution liquid chromatography-electrospray tandem mass spectrometry. The particular case of carboxymethyllysine.

    Science.gov (United States)

    Delatour, Thierry; Hegele, Jörg; Parisod, Véronique; Richoz, Janique; Maurer, Sarah; Steven, Matthew; Buetler, Timo

    2009-03-20

    A fully validated multiple-transition recording isotope dilution liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantitative determination of N(epsilon)-carboxymethyllysine (CML) and lysine in dairy products is described. Internal standards were [N-1',2'-(13)C(2)]CML and [1,2,3,4,5,6-(13)C(6)-2,6-(15)N(2)]lysine, and the method was validated by evaluating the selectivity, linearity, precision (repeatability and reproducibility) and trueness, using both powder and liquid products. For liquid dairy products, the repeatability and reproducibility was 2.79% and 11.0%, while 4.85% and 4.92% were determined for powder dairy products, respectively. The trueness of the method ranged from -9.6% to -3.6% for powder and from -0.99% to 6.8% for liquid dairy products. The limit of detection for CML was estimated to be 8 ng CML per mg protein while the limit of quantification was 27 ng CML per mg protein. The method encompasses a proteolytic cleavage mediated by enzymatic digestion to reach a complete release of the amino acids prior to a sample cleanup based on solid phase extraction, and followed by LC-MS/MS analysis of CML and lysine residues. To ensure a suitable performance of the enzymatic digestion, CML measurements were compared to values obtained with an acid hydrolysis-mediated proteolysis. Finally, the method was employed for the analysis of CML in various dairy products. The values compare well to the data available in the literature when similar methods were used, even if some discrepancies were observed upon comparison with the results obtained by other techniques such as enzyme-linked immunosorbent assay and GC-MS.

  10. Fully automated analysis of beta-lactams in bovine milk by online solid phase extraction-liquid chromatography-electrospray-tandem mass spectrometry.

    Science.gov (United States)

    Kantiani, Lina; Farré, Marinella; Sibum, Martin; Postigo, Cristina; López de Alda, Miren; Barceló, Damiá

    2009-06-01

    A fully automated method for the detection of beta-lactam antibiotics, including six penicillins (amoxicillin, ampicillin, cloxacillin, dicloxacillin, oxacillin, and penicillin G) and four cephalosporins (cefazolin, ceftiofur, cefoperazone, and cefalexin) in bovine milk samples has been developed. The outlined method is based on online solid-phase extraction-liquid chromatography/electrospray-tandem mass spectrometry (SPE-LC/ESI-MS-MS). Target compounds were concentrated from 500 microL of centrifuged milk samples using an online SPE procedure with C18 HD cartridges. Target analytes were eluted with a gradient mobile phase (water + 0.1% formic acid/methanol + 0.1% formic acid) at a flow rate of 0.7 mL/min. Chromatographic separation was achieved within 10 min using a C-12 reversed phase analytical column. For unequivocal identification and confirmation, two multiple reaction monitoring (MRM) transitions were acquired for each analyte in the positive electrospray ionization mode (ESI(+)). Method limits of detection (LODs) in milk were well below the maximum residue limits (MRLs) set by the European Union for all compounds. Limits of quantification in milk were between 0.09 ng/mL and 1.44 ng/mL. The developed method was validated according to EU's requirements, and accuracy results ranged from 80 to 116%. Finally, the method was applied to the analysis of twenty real samples previously screened by the inhibition of microbial growth test Eclipse 100. This new developed method offers high sensitivity and accuracy of results, minimum sample pre-treatment, and uses for the first time an automated online SPE offering a high throughput analysis. Because of all these characteristics, the proposed method is applicable and could be deemed necessary within the field of food control and safety. PMID:19402673

  11. Letter: characterisation and identification of spermine and spermidine derivatives in Microdesmis keayana and Microdesmis puberula roots by electrospray ionisation tandem mass spectrometry and high-performance liquid chromatography/electrospray ionisation tandem mass spectrometry.

    Science.gov (United States)

    Roumy, Vincent; Hennebelle, Thierry; Zamblé, Alexis; Zamblé Yao, Jacques; Sahpaz, Sevser; Bailleul, François

    2008-01-01

    Three new N(1),N(5),N(14)-tris(4- hydroxycinnamoyl)spermines were identified in hydromethanolic root extracts of Microdesmis keayana J. Léonard and Microdesmis puberula Hook f. The electrospray ionisation tandem mass spectrometry (ESI-MS/MS) technique with specific nuclear magnetic resonance analysis of hydrolysed products made it possible to identify N(1),N(5),N(14)-tris(p-coumaroyl)spermine, N(1)-feruloyl,N(5),N(14)-di(p-coumaroyl)spermine and N(1),N(5),N(14)-tris(feruloyl)spermine, named keayanines B, C and D, respectively. ESI-MS/MS analysis most effectively provided structural data although high-performance liquid chromatography/electrospray ionisation tandem mass spectrometry was also used to characterise four other compounds from Microdesmis puberula-keayanidines A, B, C and keayanine A-which had already been identified in M. keayana. This chemical data is the first to be published for M. puberula which is a commonly used plant in Central African traditional medicine. PMID:18493101

  12. Determination of cocaine and benzoylecgonine in nails by liquid chromatography-electrospray ionization-tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Marzena Sykutera

    2015-02-01

    Full Text Available Nails and hair are a biological matrix which can be analyzed to confirm the use of a xenobiotic even several months after intake. Results of nail analysis can be used, for example, as evidence in civil and criminal law cases in which a history of drug use can influence the court’s decision. The paper presents results of analysis of a nail sample taken from a man who was suspected of trafficking cocaine. The suspect pleaded guilty to the possession of the drug for his own use because, as he claimed, he was addicted to cocaine. A nail sample was taken. Detection and quantification were carried out using liquid chromatography-mass spectrometry (LC-ESI-MS. The concentration of cocaine in nails was found to be 47 ng/mg, and benzoylecgonine – 14 ng/mg.

  13. Determination of tamsulosin in human aqueous humor and serum by liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Keski-Rahkonen, Pekka; Pärssinen, Olavi; Leppänen, Esa; Mauriala, Timo; Lehtonen, Marko; Auriola, Seppo

    2007-01-17

    A simple, sensitive and selective LC-MS/MS method was developed for the determination of tamsulosin in human aqueous humor and serum to study the recently reported eye-related adverse effects of this alpha(1)-blocker drug. Aqueous humor samples were analyzed by direct injection, after addition of the internal standard, labetalol. Liquid-liquid extraction with ethyl acetate was used for serum sample preparation. The chromatographic separation was performed on a reversed phase column by gradient elution with acetonitrile -0.1% formic acid at a flow-rate of 0.2 ml/min. Detection and quantification of the analytes were carried out with a linear ion trap mass spectrometer, using positive electrospray ionization (ESI) and multiple reaction monitoring (MRM). The limit of quantification was 0.1 ng/ml for both aqueous humor and serum samples and linearity was obtained over the concentration ranges of 0.1-4.7 ng/ml and 0.1-19.3 ng/ml for aqueous humor and serum samples, respectively. Acceptable accuracy and precision were obtained for concentrations within the standard curve ranges. The method has been used for the determination of tamsulosin in aqueous humor and serum samples from patients that were on tamsulosin medication and underwent cataract surgery.

  14. Characterisation of cholera toxin by liquid chromatography - Electrospray mass spectrometry

    NARCIS (Netherlands)

    Baar, B.L.M. van; Hulst, A.G.; Wils, E.R.J.

    1999-01-01

    Cholera toxin, one of the toxins that may be generated by various strains of the bacterium Vibrio cholerae, can be considered as a substance possibly used in biological warfare. The possibilities of characterising the toxin by liquid chromatography electrospray mass spectrometry (LC-ES-MS) were inve

  15. Diclofenac in municipal wastewater treatment plant: quantification using laser diode thermal desorption--atmospheric pressure chemical ionization--tandem mass spectrometry approach in comparison with an established liquid chromatography-electrospray ionization-tandem mass spectrometry method.

    Science.gov (United States)

    Lonappan, Linson; Pulicharla, Rama; Rouissi, Tarek; Brar, Satinder K; Verma, Mausam; Surampalli, Rao Y; Valero, José R

    2016-02-12

    Diclofenac (DCF), a prevalent non-steroidal anti-inflammatory drug (NSAID) is often detected in wastewater and surface water. Analysis of the pharmaceuticals in complex matrices is often laden with challenges. In this study a reliable, rapid and sensitive method based on laser diode thermal desorption/atmospheric pressure chemical ionization (LDTD/APCI) coupled with tandem mass spectrometry (MS/MS) has been developed for the quantification of DCF in wastewater and wastewater sludge. An established conventional LC-ESI-MS/MS (liquid chromatography-electrospray ionization-tandem mass spectrometry) method was compared with LDTD-APCI-MS/MS approach. The newly developed LDTD-APCI-MS/MS method reduced the analysis time to 12s in lieu of 12 min for LC-ESI-MS/MS method. The method detection limits for LDTD-APCI-MS/MS method were found to be 270 ng L(-1) (LOD) and 1000 ng L(-1) (LOQ). Furthermore, two extraction procedures, ultrasonic assisted extraction (USE) and accelerated solvent extraction (ASE) for the extraction of DCF from wastewater sludge were compared and ASE with 95.6 ± 7% recovery was effective over USE with 86 ± 4% recovery. The fate and partitioning of DCF in wastewater (WW) and wastewater sludge (WWS) in wastewater treatment plant was also monitored at various stages of treatment in Quebec Urban community wastewater treatment plant. DCF exhibited affinity towards WW than WWS with a presence about 60% of DCF in WW in contrary with theoretical prediction (LogKow=4.51).

  16. Diclofenac in municipal wastewater treatment plant: quantification using laser diode thermal desorption--atmospheric pressure chemical ionization--tandem mass spectrometry approach in comparison with an established liquid chromatography-electrospray ionization-tandem mass spectrometry method.

    Science.gov (United States)

    Lonappan, Linson; Pulicharla, Rama; Rouissi, Tarek; Brar, Satinder K; Verma, Mausam; Surampalli, Rao Y; Valero, José R

    2016-02-12

    Diclofenac (DCF), a prevalent non-steroidal anti-inflammatory drug (NSAID) is often detected in wastewater and surface water. Analysis of the pharmaceuticals in complex matrices is often laden with challenges. In this study a reliable, rapid and sensitive method based on laser diode thermal desorption/atmospheric pressure chemical ionization (LDTD/APCI) coupled with tandem mass spectrometry (MS/MS) has been developed for the quantification of DCF in wastewater and wastewater sludge. An established conventional LC-ESI-MS/MS (liquid chromatography-electrospray ionization-tandem mass spectrometry) method was compared with LDTD-APCI-MS/MS approach. The newly developed LDTD-APCI-MS/MS method reduced the analysis time to 12s in lieu of 12 min for LC-ESI-MS/MS method. The method detection limits for LDTD-APCI-MS/MS method were found to be 270 ng L(-1) (LOD) and 1000 ng L(-1) (LOQ). Furthermore, two extraction procedures, ultrasonic assisted extraction (USE) and accelerated solvent extraction (ASE) for the extraction of DCF from wastewater sludge were compared and ASE with 95.6 ± 7% recovery was effective over USE with 86 ± 4% recovery. The fate and partitioning of DCF in wastewater (WW) and wastewater sludge (WWS) in wastewater treatment plant was also monitored at various stages of treatment in Quebec Urban community wastewater treatment plant. DCF exhibited affinity towards WW than WWS with a presence about 60% of DCF in WW in contrary with theoretical prediction (LogKow=4.51). PMID:26805597

  17. Multiresidue analysis of beta-agonists in bovine and porcine unrine, feed and hair using liquid chromatography electrospray ionisation tandem mass spectrometry

    NARCIS (Netherlands)

    Nielen, M.W.F.; Lasaroms, J.J.P.; Essers, M.L.; Oosterink, J.E.; Meijer, T.; Sanders, M.B.; Zuidema, T.; Stolker, A.A.M.

    2008-01-01

    The use of ß-agonists as growth promoters in cattle breeding is forbidden in many countries for reasons of fair trade and consumer protection. In recent years the use of liquid chromatography (LC) tandem mass spectrometry (MS/MS) has been shown to be the method of choice for the control of ß-agonist

  18. Analysis of [3′,3′-d2]-nicotine and [3′,3′-d2]-cotinine by capillary liquid chromatography-electrospray tandem mass spectrometry

    OpenAIRE

    Murphy, Sharon E.; Villalta, Peter; Ho, Sing-Wei; von Weymarn, Linda B.

    2007-01-01

    A selective and sensitive LC/MS/MS assay was developed for the quantification of d2-nicotine and d2-cotinine in plasma of current and past smokers administered d2-nicotine. After solid phase extraction and liquid liquid extraction, HPLC separation was achieved on a capillary hydrophilic interaction chromatography phase column. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated for d2-nicotine (0.03 to 6.0 ng/...

  19. Analysis of caged xanthones from the resin of Garcinia hanburyi using ultra-performance liquid chromatography/electrospray ionization quadrupole time-of-flight tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhou Yan [Hong Kong Jockey Club Institute of Chinese Medicine, Shatin, Hong Kong (China); Liu Xin [Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu 610041, Sichuan Province (China); Yang Jing [School of Chemistry and Chemical Technology, Shanghai Jiao Tong University, Shanghai 200240 (China); Han Quanbin; Song Jingzheng; Li Songlin; Qiao Chunfeng [Hong Kong Jockey Club Institute of Chinese Medicine, Shatin, Hong Kong (China); Ding Lisheng [Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu 610041, Sichuan Province (China)], E-mail: lsding@cib.ac.cn; Xu Hongxi [Hong Kong Jockey Club Institute of Chinese Medicine, Shatin, Hong Kong (China)], E-mail: xuhongxi@hkjcicm.org

    2008-11-23

    On-line ultra high-performance liquid chromatography (UHPLC) coupled with electrospray quadrupole time-of-flight tandem mass spectrometry (ESI-QTOF-MS/MS/MS) has been developed for the analysis of a series of caged xanthones in the resin of Garcinia hanburyi. The fragmentation of protonated molecular ions for 12 known cadged xanthones was carried out using low-energy collision-induced electrospray ionization tandem mass spectrometry. It was found that Retro-Diels-Alder rearrangement occurred in the CID processes and produced the characteristic fragment ions, which are especially valuable for the identification of this class of xanthones. The fragmentation differential between some cis-, trans-isomers was uncovered. Computation methods were utilized to rationalize the observed MS behaviors. On-line UHPLC-ESI-MS/MS/MS method has proved to be rapid and efficient in that within 6 min, 15 caged scaffold xanthones, including three pairs of epimers and four pairs of isomers in gamboges, were effectively separated and identified. Among them, two known, namely isogambogenin (13) and isomorellinol (14) and one likely new caged Garcinia xanthones from the Garcinia hanburyi were tentatively characterized based on the tandem mass spectra of known ones.

  20. Analysis of caged xanthones from the resin of Garcinia hanburyi using ultra-performance liquid chromatography/electrospray ionization quadrupole time-of-flight tandem mass spectrometry

    International Nuclear Information System (INIS)

    On-line ultra high-performance liquid chromatography (UHPLC) coupled with electrospray quadrupole time-of-flight tandem mass spectrometry (ESI-QTOF-MS/MS/MS) has been developed for the analysis of a series of caged xanthones in the resin of Garcinia hanburyi. The fragmentation of protonated molecular ions for 12 known cadged xanthones was carried out using low-energy collision-induced electrospray ionization tandem mass spectrometry. It was found that Retro-Diels-Alder rearrangement occurred in the CID processes and produced the characteristic fragment ions, which are especially valuable for the identification of this class of xanthones. The fragmentation differential between some cis-, trans-isomers was uncovered. Computation methods were utilized to rationalize the observed MS behaviors. On-line UHPLC-ESI-MS/MS/MS method has proved to be rapid and efficient in that within 6 min, 15 caged scaffold xanthones, including three pairs of epimers and four pairs of isomers in gamboges, were effectively separated and identified. Among them, two known, namely isogambogenin (13) and isomorellinol (14) and one likely new caged Garcinia xanthones from the Garcinia hanburyi were tentatively characterized based on the tandem mass spectra of known ones

  1. A generic and rapid strategy for determining trace multiresidues of sulfonamides in aquatic products by using an improved QuEChERS method and liquid chromatography-electrospray quadrupole tandem mass spectrometry.

    Science.gov (United States)

    Kung, Te-An; Tsai, Chung-Wei; Ku, Bing Chang; Wang, Wei-Hsien

    2015-05-15

    A rapid and efficient multiresidue method that involves using improved QuEChERS method and liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) was developed to measure trace levels of sulfonamides in fish tissue. This proposed method was proven to be a powerful, highly sensitive, and environmentally friendly analytical tool that requires minimal sample preparation. The typical MS/MS fragmentation patterns of the [M+H](+) were 156 m/z, 108 m/z, and 92 m/z. Separation was performed on HC-C18 columns with a gradient elution by using methanol -5mM ammonium acetate containing formic acid (pH 3.5). This method was validated and exhibited favorable performance as well as acceptable accuracy (80.2-93.5%), precision (3.82-8.71%), sensitivity (limits of detection (LODs) 0.43-1.22 μg kg(-1), limits of quantification (LOQs) 1.27-3.71 μg kg(-1); decision limit (CCα) 1.49-10.9 μg kg(-1), detection capability (CCβ) 1.71-11.4 μg kg(-1)), and an acceptable matrix effect (-18.2-18.4%). This methodology has been successfully applied in analyzing various fish tissue from local markets.

  2. Optimized combination of dilution and refined QuEChERS to overcome matrix effects of six types of tea for determination eight neonicotinoid insecticides by ultra performance liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Jiao, Weiting; Xiao, Yu; Qian, Xiaosan; Tong, Mengmeng; Hu, Yizheng; Hou, Ruyan; Hua, Rimao

    2016-11-01

    Liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) is a primary tool for analysis of low volatility compounds in complex matrices. However, complex matrices, such as different types of tea, complicate analysis through ionization suppression or enhancement. In this study, sample preparation by a refined QuEChERS method combined with a dilution strategy removed almost all matrix effects caused by six types of tea. Tea samples were soaked with water and extracted with acetonitrile, cleaned up with a combination of PVPP (160mg) and GCB (20mg), and dried. Dried extracts were diluted with 20mL acetonitrile/water (15:85, v/v) before analysis by UPLC-MS/MS. The average recoveries of eight neonicotinoid insecticides (dinotefuran, nitenpyram, thiamethoxam, imidacloprid, clothianidin, imidaclothiz, acetamiprid, and thiacloprid) ranged from 66.3 to 108.0% from tea samples spiked at 0.01-0.5mgkg(-1). Relative standard deviations were below 16% for all recovery tests. The limit of quantification ranged from 0.01 to 0.05mgkg(-1). PMID:27211616

  3. Determination of benzothiazole and benzotriazole derivates in tire and clothing textile samples by high performance liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Avagyan, Rozanna; Sadiktsis, Ioannis; Thorsén, Gunnar; Östman, Conny; Westerholm, Roger

    2013-09-13

    A high performance liquid chromatography-tandem mass spectrometry method utilizing electrospray ionization in positive and negative mode has been developed for the separation and detection of benzothiazole and benzotriazole derivates. Ultra-sonication assisted solvent extraction of these compounds has also been developed and the overall method demonstrated on a selected clothing textile and an automobile tire sample. Matrix effects and extraction recoveries, as well as linearity and limits of detection have been evaluated. The calibration curves spanned over more than two orders of magnitude with coefficients of correlation R(2)>0.99 and the limits of detection and the limits of quantification were in the range 1.7-58pg injected and 18-140pg/g, respectively. The extraction recoveries ranged between 69% and 102% and the matrix effects between 75% and 101%. Benzothiazole and benzotriazole derivates were determined in the textile sample and benzothiazole derivatives determined in the tire sample with good analytical performance.

  4. Simultaneous determination of human and veterinary antibiotics in various environmental matrices by rapid resolution liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Li-Jun; Ying, Guang-Guo; Liu, Shan; Zhao, Jian-Liang; Chen, Feng; Zhang, Rui-Quan; Peng, Fu-Qiang; Zhang, Qian-Qian

    2012-06-29

    A robust and sensitive analytical method is presented in which 11 classes of antibiotics are simultaneously extracted and determined in surface water, lagoon wastewater, influent, effluent, sediment, manure and sludge. Water samples with different volumes were adjusted to pH 3, added with 0.2g Na₂EDTA and then extracted using Oasis hydrophilic-lipophilic balance (HLB) cartridges. Extraction of solid samples was carried out by a combination of ultrasonic and vortex mixing using a mixture of acetonitrile and citric buffer at pH 3 as the extraction solution. The extracts of the solid samples were then cleaned-up by a tandem solid phase extraction (SPE) method using a strong anion exchange cartridge (SAX) and a HLB cartridge, followed by analysis using rapid resolution liquid chromatography-tandem mass spectrometry (RRLC-MS/MS) equipped with electrospray ionization source. Among the 50 target compounds, the recoveries in the range of 50-150% were obtained for 39, 40, 36, 40, 38, 33 and 36 antibiotics in the spiked samples of surface water, lagoon wastewater, influent, effluent, sediment, manure and sludge with three concentrations, respectively. Method quantification limits (MQLs) for the target compounds (except sulfaguanidine and sulfanilamide) were in the range of 0.52-5.88 ng/L, 2.36-65.8 ng/L, 1.73-20 ng/L, 1.42-9.52 ng/L, 0.64-6.67 ng/g (except bacitracin and cloxacillin), 1.33-17.4 ng/g (except salinomycin, narasin, monensin, cloxacillin and novobiocin) and 1.50-28.6 ng/g (except salinomycin, narasin, monensin and cloxacillin) in surface water, lagoon wastewater, influent, effluent, sediment, manure and sludge, respectively. The developed analytical method was successfully applied in the determination of target compounds in wastewater and sludge samples from Huiyang wastewater treatment plants, and in ground water, lagoon wastewater, manure and sediment collected from a pig farm, in South China. PMID:22625208

  5. Simultaneous determination of acrylamide, its metabolite glycidamide and antipyrine in human placental perfusion fluid and placental tissue by liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Annola, Kirsi; Keski-Rahkonen, Pekka; Vähäkangas, Kirsi; Lehtonen, Marko

    2008-12-15

    A rapid and sensitive method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the simultaneous determination of acrylamide (AA) and its genotoxic metabolite glycidamide (GA) with a test marker antipyrine (AP) in placental tissue and perfusion medium used in human placental perfusion studies. An internal standard ((13)C-acrylamide) was added to the samples which were then deproteinized with acetonitrile. Chromatographic separation was performed on a reversed phase column with a gradient elution of acetonitrile and 0.01% formic acid at a flow rate of 0.3 mL/min. Detection and quantification of the analytes were carried out with a triple quadrupole mass spectrometer using positive electrospray ionization (ESI) and multiple reaction monitoring (MRM). The method was validated and linear over a concentration range of 0.5-20 microg/mL for acrylamide and glycidamide and 5-200 microg/mL for antipyrine. The lower limit of quantification for acrylamide and glycidamide was 0.5 microg/mL and for antipyrine 5 microg/mL. The method was selective, and good accuracy, precision, recovery, and stability were obtained for concentrations within the standard curve. The method was successfully used to analyze the placental perfusion medium and tissue samples in a toxicokinetic study for transplacental transfer of acrylamide and glycidamide. This is the first time that acrylamide, glycidamide and antipyrine are measured simultaneously.

  6. Trace analysis of trimethoprim and sulfonamide, macrolide, quinolone, and tetracycline antibiotics in chlorinated drinking water using liquid chromatography electrospray tandem mass spectrometry

    Science.gov (United States)

    Ye, Z.; Weinberg, H.S.; Meyer, M.T.

    2007-01-01

    A multirun analytical method has been developed and validated for trace determination of 24 antibiotics including 7 sulfonamides, 3 macrolides, 7 quinolones, 6 tetracyclines, and trimethoprim in chlorine-disinfected drinking water using a single solid-phase extraction method coupled to liquid chromatography with positive electrospray tandem mass spectrometry detection. The analytes were extracted by a hydrophilic-lipophilic balanced resin and eluted with acidified methanol (0.1% formic acid), resulting in analyte recoveries generally above 90%. The limits of quantitation were mostly below 10 ng/L in drinking water. Since the concentrated sample matrix typically caused ion suppression during electrospray ionization, the method of standard addition was used for quantitation. Chlorine residuals in drinking water can react with some antibiotics, but ascorbic acid was found to be an effective chlorine quenching agent without affecting the analysis and stability of the antibiotics in water. A preliminary occurrence study using this method revealed the presence of some antibiotics in drinking waters, including sulfamethoxazole (3.0-3.4 ng/L), macrolides (1.4-4.9 ng/L), and quinolones (1.2-4.0 ng/L). ?? 2007 American Chemical Society.

  7. Ultra-performance liquid chromatography electrospray ionization–tandem mass spectrometry method for the simultaneous determination of itraconazole and hydroxy itraconazole in human plasma

    Directory of Open Access Journals (Sweden)

    Ashish Dwivedi

    2014-10-01

    Full Text Available A highly sensitive, selective, and precise ultra-performance liquid chromatography tandem mass spectrometry method was developed and validated for simultaneous quantification of itraconazole and hydroxy itraconazole in human plasma by a single liquid–liquid extraction step. The precursor to product ion transitions of m/z 705.3/392.3, m/z 721.2/408.3 and m/z 708.2/435.4 were used to detect and quantify itraconazole, hydroxy itraconazole and itraconazole-d3 respectively. The lower limit of quantitation was found to be 0.500 ng/mL for itraconazole and 1.00 ng/mL for hydroxy itraconazole. The mean recoveries for itraconazole and hydroxy itraconazole were found to be 100.045% and 100.021%, respectively. This developed method with a chromatographic run time of 2.0 min was successfully applied to a bioequivalence study of 100 mg itraconazole capsule.

  8. Determination of therapeutic γ-aminobutyric acid analogs in forensic whole blood by hydrophilic interaction liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Sørensen, Lambert K; Hasselstrøm, Jørgen B

    2014-05-01

    Vigabatrin, pregabalin, gabapentin and baclofen are γ-aminobutyric acid analogs that are used in the treatment of epileptic seizures (vigabatrin, pregabalin and gabapentin) and spasticity (baclofen). The intake of these drugs may induce adverse reactions and impair the ability of an individual to drive a vehicle. There have also been reports of cases of intoxication and fatalities from overdoses. For rapid and accurate quantification of these drugs in forensic cases, an ultraperformance liquid chromatography tandem mass spectrometry method using pneumatically assisted electrospray ionization has been developed. The technique has been validated on both ante- and postmortem human whole blood. The protein in the blood samples was removed by the addition of a mixture of methanol and acetonitrile, and the extract was ultrafiltered and diluted with acetonitrile. The separation was performed by hydrophilic interaction liquid chromatography. Calibration of the system was achieved through use of matrix-matched calibrants combined with isotope dilution. The lower limits of quantification were 0.02-0.04 mg/L, and the relative intra-laboratory reproducibility standard deviations were 89%. The trueness expressed as the relative bias of the test results was within ±7% at concentrations of 1-40 mg/L for vigabatrin, pregabalin and gabapentin and of 0.1-4 mg/L for baclofen.

  9. Efficient and sensitive detection of residues of nine coccidiostats in egg and muscle by liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Dubois, M; Pierret, G; Delahaut, Ph

    2004-12-25

    We present a method based on electrospray liquid chromatography tandem mass spectrometry (LC-MS/MS) for determining in muscle and eggs the following nine coccidiostats: halofuginone, diclazuril, dinitrocarbanilide (the main metabolite of nicarbazin), robenidine, monensin, lasalocid, narasin, salinomycin, and maduramicin. Dinitrocarbanilide-d8, nigericin, and diclazuril-bis were used as internal standards. The method uses extraction in acetonitrile followed by a clean-up on an SiOH solid-phase extraction column. High-performance liquid chromatography (HPLC) separation was performed on a Purospher C(18) column (125 mm x 3 mm i.d.) protected by a guard column, the mobile phase being a water-acetonitrile gradient (each gradient component containing 0.1% formic acid) at a flow rate of 1 ml min(-1). For unequivocal identification of each analyte, two ions were detected and chosen for multiple reaction monitoring (MRM). Validation was carried out on spiked muscle and egg samples. The method described meets all the criteria of Decision 2002/657/EC and is easy to use in routine analysis. Validation results are presented with the measured CCalpha and CCbeta values. This whole method allows extraction and analysis of up to 24 samples per day.

  10. Validation of a liquid chromatography-electrospray ionization tandem mass spectrometric method to determine six polyether ionophores in raw, UHT, pasteurized and powdered milk.

    Science.gov (United States)

    Pereira, Mararlene Ulberg; Spisso, Bernardete Ferraz; Jacob, Silvana do Couto; Monteiro, Mychelle Alves; Ferreira, Rosana Gomes; Carlos, Betânia de Souza; da Nóbrega, Armi Wanderley

    2016-04-01

    This study aimed to validate a method developed for the determination of six antibiotics from the polyether ionophore class (lasalocid, maduramicin, monensin, narasin, salinomycin and semduramicin) at residue levels in raw, UHT, pasteurized and powdered milk using QuEChERS extraction and high performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS). The validation was conducted under an in-house laboratory protocol that is primarily based on 2002/657/EC Decision, but takes in account the variability of matrix sources. Overall recoveries between 93% and 113% with relative standard deviations up to 16% were obtained under intermediate precision conditions. CCα calculated values did not exceed 20% the Maximum Residue Limit for monensin and 25% the Maximum Levels for all other substances. The method showed to be simple, fast and suitable for verifying the compliance of raw and processed milk samples regarding the limits recommended by Codex Alimentarius and those adopted in European Community for polyether ionophores. PMID:26593474

  11. Comparison of rapid liquid chromatography-electrospray ionization-tandem mass spectrometry methods for determination of glycoalkaloids in transgenic field-grown potatoes.

    Science.gov (United States)

    Zywicki, Britta; Catchpole, Gareth; Draper, John; Fiehn, Oliver

    2005-01-15

    Two rapid methods for highly selective detection and quantification of the two major glycoalkaloids in potatoes, alpha-chaconine and alpha-solanine, were compared for robustness in high-throughput operations for over 1000 analytical runs using potato tuber samples from field trials. Glycoalkaloids were analyzed using liquid chromatography coupled to tandem mass spectrometry in multiple reaction monitoring mode. An electrospray interface was used in the detection of glycoalkaloids in positive ion mode. Classical reversed phase (RP) and hydrophilic interaction (HILIC) columns were investigated for chromatographic separation, ruggedness, recovery, precision, and accuracy. During the validation procedure both methods proved to be precise and accurate enough in relation to the high degree of endogenous biological variability found for field-grown potato tubers. However, the RP method was found to be more precise, more accurate, and, more importantly, more rugged than the HILIC method for maintaining the analytes' peak shape symmetry in high-throughput operation. When applied to the comparison of six classically bred potato cultivars to six genetically modified (GM) lines engineered to synthesize health beneficial inulins, the glycoalkaloid content in potato peels of all GM lines was found within the range of the six cultivars. We suggest complementing current unbiased metabolomic strategies by validating quantitative analytical methods for important target analytes such as the toxic glycoalkaloids in potato plants. PMID:15620882

  12. Liquid chromatography-electrospray ionization tandem mass spectrometry for on-line characterization, monitoring and isotopic profiling of the main selenium-metabolite in human urine after consumption of Se-rich and Se-enriched food

    International Nuclear Information System (INIS)

    The metabolism of selenium (Se) in the human body has yet not completely been unravelled and hence, an efficient method for characterization and on-line monitoring of the main Se-compound in human urine after consumption of Se-rich food was developed. Total Se-concentration in human urine after consumption of several Se-rich products was measured with inductively coupled plasma mass spectrometry (ICP-MS). The highest Se concentration in urine was observed after 4-10 h. The urine samples were brought onto a reversed phase column and the Se was detected by ICP-MS. Parameters for liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS) measurements were optimized by using commercially available sugars, because it is known that some of the urinary metabolites contain a sugar moiety. In order to characterize the predominant Se-metabolite, it was necessary to extensively clean-up the sample and preconcentrate the species. The main metabolite was measured on its precursor ion on three different m/z according to three isotopes of Se. Relative peak surfaces matched the relative abundances of the isotopes. The product ions could be measured in a human urine sample in accordance to the product ions of the commercially available sugars. Moreover, the evidence of a selenosugar was demonstrated by the use of the Se-isotopes when measuring the product ions. LC-ESI-MS-MS was proven to be very efficient for the characterization of the main urinary Se-metabolite and can be used for on-line monitoring of the compound in urine samples. The method can be extended for clinical screening after consumption of Se-(en)rich(ed) food by use of the Se-isotopic profile and/or of the typical product ions of (methyl)-N-acetyl-hexosamines

  13. Precolumn derivatization reagents for high-speed analysis of amines and amino acids in biological fluid using liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Shimbo, Kazutaka; Oonuki, Takashi; Yahashi, Akihisa; Hirayama, Kazuo; Miyano, Hiroshi

    2009-05-01

    A rapid analytical method for amines and amino acids was developed, involving derivatization with the novel reagent 3-aminopyridyl-N-hydroxysuccinimidyl carbamate (APDS), followed by reversed-phase high-performance liquid chromatography and electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS). More than 100 different analytes with amino groups, including amino acids in biological fluids such as mammalian plasma, could be measured within 10 min. The analytes were easily derivatized with APDS under the mild conditions. Selective reaction monitoring of ESI-MS/MS in positive mode was carried out to include the transitions of all of the protonated molecular ions of analytes derivatized with APDS to the common fragment at m/z 121, which was derived from the amino pyridyl moiety of the reagent. We evaluated the retention time precision, the quantification limits, the linearity, the intra- and inter-day precisions and the accuracy of 22 typical amino acids found in biological fluids, by analyzing a standard amino acid mixture and rat plasma. The intra-day relative standard deviations (RSDs) of the retention times of the 22 amino acids and their internal standards were within 0.9% and the inter-day RSDs were less than 1.1%, except for asparagines, with an RSD of 1.9%. The intra-day and inter-day RSDs of amino acid analyses in rat plasma were within 8.0% and 4.5%, respectively. The method, which facilitates the amino acid analysis of more than 100 samples in a day, represents an alternative to traditional amino acid analysis techniques, such as chromatography using postcolumn derivatization by ninhydrin. PMID:19350529

  14. Rapid and simultaneous analysis of ten aromatic amines in mainstream cigarette smoke by liquid chromatography/electrospray ionization tandem mass spectrometry under ISO and "Health Canada intensive" machine smoking regimens.

    Science.gov (United States)

    Xie, Fuwei; Yu, Jingjing; Wang, Sheng; Zhao, Ge; Xia, Qiaoling; Zhang, Xiaobing; Zhang, Shusheng

    2013-10-15

    Ten primary aromatic amines (AAs) in mainstream cigarette smoke under both ISO and "Health Canada intensive" machine smoking regimens were determined in this work, which were suspected to be carcinogenic compounds. The measured AAs included aniline, ortho-toluidine, meta-toluidine, para-toluidine, 1-naphthylamine, 2-naphthylamine, 3-aminobiphenyl, 4-aminobiphenyl, meta-phenylenediamine and meta-anisidine. For rapidly and sensitively analyzing these AAs, a liquid chromatography-electrospray ionization tandem mass spectrometric (LC-MS/MS) method coupled with solid phase extraction (SPE) was developed. The particulate phase of mainstream cigarette smoke was collected on a Cambridge filter pads, while the gas phase was trapped by 25 mL 5% HCl solution. Then, the pad was extracted in an ultrasonic bath with the impinger HCl solution. After being neutralized with NaOH, the extract was purified with a HLB solid phase extraction column, and then was analyzed with LC-MS/MS using isotope-labeled internal standard. The overall sample pretreatment and analysis time was less than 1.5h. The limits of detection for all targets ranged from 0.05 ng cig(-1) to 0.96 ng cig(-1) with the recoveries in the range of 75.0-131.8%. And the intra-day and inter-day precisions were less than 10% and 16%, respectively. Under HCI machine smoking regimen, the AAs yields in mainstream cigarette smoke were much higher and the average increases were greater than 100% compared with those under ISO smoking condition. PMID:24054615

  15. Determination of gardenia yellow colorants in soft drink, pastry, instant noodles with ultrasound-assisted extraction by high performance liquid chromatography-electrospray ionization tandem mass spectrum.

    Science.gov (United States)

    Zhou, Wei-E; Zhang, Yuan; Li, Yang; Ling, Yun; Li, Hong-Na; Li, Shao-Hui; Jiang, Shou-Jun; Ren, Zhi-Qin; Huang, Zhi-Qiang; Zhang, Feng

    2016-05-13

    A novel, rapid and simple analytical method was developed for the quantitative determination of crocin, crocetin and geniposide in soft drink, pastry and instant noodles. The solid samples were relatively homogenized into powders and fragments. The gardenia yellow colorants were successively extracted with methanol using ultrasound-assisted extraction. The analytes were quantitatively measured in the extracts by liquid chromatography coupled with electrospray ionization tandem mass spectrometry. High correlation coefficients (r(2)>0.995) of crocin, crocetin and geniposide were obtained within their linear ranges respectively (50-1000ng/mL, 50-1000ng/mL, 15-240ng/mL) by external standard method. The limits of detection (LODs) were 0.02μg/g for crocin, 0.01μg/g for crocetin and 0.002μg/g for geniposide. And the limits of quantitation (LOQs) were in the ranges of 0.05-0.45μg/g for crocin, and in the ranges of 0.042-0.32μg/g for crocetin, and in the ranges of 0.02-0.15μg/g for geniposide in soft drink, pastry and instant noodles samples. The average recoveries of crocin, crocetin and geniposide ranged from 81.3% to 117.6% in soft drink, pastry and instant noodles. The intra- and inter-day precisions were respectively in the range of 1.3-4.8% and 1.7-11.8% in soft drink, pastry and instant noodle. The developed methods were successfully validated and applied to the soft drink, pastry, and instant noodles collected from the located market in Beijing from China. Crocin, crocetin and geniposide were detected in the collected samples. The average concentrations ranged from 0.84 to 4.20mg/g for crocin, and from 0.62 to 3.11mg/g for crocetin, and from 0.18 to 0.79mg/g for gardenia in various food samples. The method can provide evidences for government to determine gardenia yellow pigments and geniposide in food. PMID:27086566

  16. Determination of carnitine and acylcarnitines in urine by high-performance liquid chromatography-electrospray ionization ion trap tandem mass spectrometry.

    Science.gov (United States)

    Vernez, Laurence; Hopfgartner, Gérard; Wenk, Markus; Krähenbühl, Stephan

    2003-01-17

    A high-performance liquid chromatography-mass spectrometry method has been developed for the simultaneous determination of native carnitine and eight acylcarnitines in urine. The procedure uses a solid-phase extraction on a cation-exchange column and the separation is performed without derivatization within 17 min on a reversed-phase C8 column in the presence of a volatile ion-pairing reagent. The detector was an ion trap mass spectrometer and quantification was carried out in the MS-MS mode. Validation was done for aqueous standards at ranges between 0.75 and 200 micromol/l, depending on the compound. Carnitine was quantified in urine and comparison with a radioenzymatic assay gave a satisfactory correlation (R2 = 0.981). The assay could be successfully applied to the diagnostic of pathological acylcarnitines profile of metabolic disorders in urines of patients suffering from different organic acidurias. PMID:12564691

  17. 液相色谱-串联质谱法测定保健食品中维生素B12%Determination of vitamin B12 in function foods by liquid chromatography electrospray ionization tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    林宏琳; 华永有; 黄宏南

    2011-01-01

    目的 建立测定保健食品中维生素B12的液相色谱-串联质谱法.方法 样品添加内标人参皂苷Re溶液,固相萃取法( SPE)对试样进行富集、净化,以甲醇(A)和纯水(B)为流动相经Bio Basic-18 PIONEER柱(150 mm×2.1 mm,5μm)梯度洗脱分离,串联离子阱质谱在电喷雾电离正离子(ESI+)-全扫描(full)-二级质谱(MS/MS)模式下按内标法测定.结果 维生素B12在50~500 ng/ml范围内具有良好的线性,相关系数r=0.992,回收率75.2% ~ 89.5%,精密度3.6%~5.9%,检出限为5 ng/g,定量限为16 ng/g.结论本法可应用于保健食品的检测或产品质量控制.%Objective To establish a method of determining vitamin B12 in health food products by liquid chromatography electrospray ionization tandem mass spectrometry (LC-MS/MS). Methods After mixing samples with internal standard solution of ginsenoside Re, the mixtures of samples were extracted by solid phase extraction, and separated on a Bio Basic-18 PIONEER column (ISO mm ×2. 1 mm, 5 u.m) by a mobile phase of methanol ( A) + water ( B) with the gradient elution program. Detection was carried out by a liquid chromatography coupled electrospray ionization and ion trap mass spectrometry with ESI + , MS/MS and full scan mode. Results Calibration curve was linear within the range of 50-SOOng/ml with a correlation coefficient of more than 0. 99; the limit of detection ( LOD) was 5 ng/g and the limit of quantification ( LOQ) was 16 ng/g. The extraction recoveries were 75.2%-88.5%, RSDs were 3.6% -5.9%. Conclusion This method could meet the requirements of domestic and international laws and regulations, and could be used in the determination of VBI2 in health food products or for the quality control of the products.

  18. Method development for the determination of selected pesticides on tobacco by high-performance liquid chromatography-electrospray ionisation-tandem mass spectrometry.

    Science.gov (United States)

    Mayer-Helm, Bernhard; Hofbauer, Ludwig; Müller, Jutta

    2008-02-15

    A method was developed for the quantitative determination of alachlor, benalaxyl, clomazone, diflubenzuron, dimethomorph, diphenamid, ethofumesate, metalaxyl, methoprene, metobromuron and piperonyl butoxide on tobacco. The pesticides were extracted with water and methanol from five different types of tobacco. The extracts were purified by partition on an extraction cartridge containing diatomaceous earth. The purified extracts were analysed by reversed-phase high-performance liquid chromatography connected to an atmospheric pressure ionisation-electrospray-triple quadrupole mass spectrometer operating in the positive ion mode. Two different transitions and their relative intensities were monitored for unambiguous identification. All pesticides presented overall recovery rates between 35% and 110%. The trueness is near 100% and the interday precision is below 15%. The limits of quantifications are equal or below the guidance residue levels proposed by the Agrochemical Advisory Committee of CORESTA, an association of organisations having scientific research relative to tobacco.

  19. Detection and confirmation of milk adulteration with cheese whey using proteomic-like sample preparation and liquid chromatography-electrospray-tandem mass spectrometry analysis.

    Science.gov (United States)

    Campos Motta, T M; Hoff, R B; Barreto, F; Andrade, R B S; Lorenzini, D M; Meneghini, L Z; Pizzolato, T M

    2014-03-01

    Caseinomacropeptide (CMP) is a peptide released by chymosin in cheese production, remaining in whey. Thus, CMP can be used as a biomarker to fluid milk adulteration through whey addition. Commonly, CMP is analyzed by reversed phase (RP-HPLC) or size-exclusion chromatography (SEC). However, some psychrotropic microorganisms - specially Pseudomonas fluorescens - when present in storaged milk, can produce, by enzymatic pathway, a CMP-like peptide generally called pseudo-CMP. These two peptides differ from each other only by one amino acid. RP-HPLC and SEC methods are unable to distinguish these two peptides, which demand development of a confirmatory method with high selectivity. Considering the several degrees of glycosilation and phosphorylation sites in CMP, allied with possible genetic variation (CMP A and CMP B), analytical methods able to differentiate these peptides are extremely complex. In the present work, we developed a proteomic-like technique for separation and characterization of these peptides, using liquid chromatography coupled to mass spectrometry with electrospray ionization able to differentiate and subsequently quantify CMP and pseudo-CMP in milk samples in order to identify adulteration or contamination of these products. The method shows satisfactory precision (<11%) with a detection limit of 1.0 µg mL(-1) and quantification limit of 5.0 µg mL(-1). Specificity, matrix effects and applicability to real samples analysis were also performed and discussed.

  20. Liquid chromatography electrospray ionization and matrix-assisted laser desorption ionization tandem mass spectrometry for the analysis of lipid raft proteome of monocytes

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Nan [Department of Chemistry, University of Alberta, Edmonton, Alberta (Canada); Shaw, Andrew R.E. [Department of Chemistry, University of Alberta, Edmonton, Alberta (Canada)], E-mail: andrewsh@cancerboard.ab.ca; Li Nan; Chen Rui [Department of Chemistry, University of Alberta, Edmonton, Alberta (Canada); Mak, Allan; Hu Xiuying [Department of Oncology, University of Alberta, Edmonton, Alberta (Canada); Young, Nelson; Wishart, David [Department of Computing Science, University of Alberta, Edmonton, Alberta (Canada); Li Liang, E-mail: Liang.Li@ualberta.ca

    2008-10-03

    Lipid rafts are dynamic assemblies of cholesterol and glycolipid that form detergent-insoluble microdomains within membrane lipid bilayers. Because rafts can be separated by flotation on sucrose gradients, interrogation by mass spectrometry (MS) provides a valuable new insight into lipid raft function. Here we combine liquid chromatography (LC) electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) MS/MS to corroborate and extend our previous description of lipid raft proteomes derived from the monocytic cell line THP-1. Interestingly, LC-ESI and MALDI MS/MS identify largely non-overlapping, and therefore, potentially complementary protein populations. Using the combined approach, we detected 277 proteins compared to 52 proteins obtained with the original gel-based MALDI MS. We confirmed the presence of 47 of the original 52 proteins demonstrating the consistency of the lipid raft preparations. We demonstrated by immunoblotting that Rac 1 and Rac 2, two of the 52 proteins we failed to confirm, were indeed absent from the lipid raft fractions. The majority of new proteins were cytoskeletal proteins and their regulators, proteins implicated in membrane fusion and vesicular trafficking or signaling molecules. Our results therefore, confirm and extend previous evidence indicating lipid rafts of monocytic cells are specialized for cytoskeletal assembly and vesicle trafficking. Of particular interest, we detected SNAP-23, basigin, Glut-4 and pantophysin in lipid rafts. Since these proteins are implicated in both vesicular trafficking and gamete fusion, lipid rafts may play a common role in these processes. It is evident that the combination of LC-ESI and LC-MALDI MS/MS increases the proteome coverage which allows better understanding of the lipid raft function.

  1. Identification of phosphorylation sites of proteins by high performance liquid chromatography-electrospray ionization-quadrupole ion trap mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    车发云; 邵晓霞; 夏其昌

    2000-01-01

    The phosphorylation sites of two phosphorylated proteins, bovine β-casein and myelin basic protein (MBP), were identified by high performance liquid chromatography-electrospray ionization-quadrupole ion trap mass spectrometry (HPLC-ESI-QITMS). The tryptic digest of each protein was separated by HPLC, the molecular weight of each peptide was determined by ESI-QITMS on line, and MS/MS spectrum of each peptide was simultaneously obtained by the combination of collision-induced desorption (CID) technique and tandem mass spectrometry (MS/MS) of QITMS. The phosphorylated peptide was identified by looking into whether the difference between the observed and predicted molecular weights of a peptide is 80 u or its integral multiple. Then the phosphorylation site was identified through manual interpretation of the MS/MS spectrum of the phosphorylated peptide or automatic SEQUEST data base-searching.

  2. Identification of phosphorylation sites of proteins by high performance liquid chromatography-electrospray ionization-quadrupole ion trap mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The phosphorylation sites of two phosphorylated proteins, bovine b-casein and myelin basic protein (MBP), were identified by high performance liquid chromatography-electrospray ionization-quadrupole ion trap mass spectrometry (HPLC-ESI-QITMS). The tryptic digest of each protein was separated by HPLC, the molecular weight of each peptide was determined by ESI-QITMS on line, and MS/MS spectrum of each peptide was simultaneously obtained by the combination of collision-induced desorption (CID) technique and tandem mass spectrometry (MS/MS) of QITMS. The phosphorylated peptide was identified by looking into whether the difference between the observed and predicted molecular weights of a peptide is 80 u or its integral multiple. Then the phosphorylation site was identified through manual interpretation of the MS/MS spectrum of the phosphorylated peptide or automatic SEQUEST data base-searching.

  3. Evaluation of Offline Tandem and Online Solid-Phase Extraction with Liquid Chromatography/Electrospray Ionization-Mass Spectrometry for Analysis of Antibiotics in Ambient Water and Comparison to an Independent Method

    Science.gov (United States)

    Meyer, M.T.; Lee, E.A.; Ferrell, G.M.; Bumgarner, J.E.; Varns, Jerry

    2007-01-01

    This report describes the performance of an offline tandem solid-phase extraction (SPE) method and an online SPE method that use liquid chromatography/mass spectrometry for the analysis of 23 and 35 antibiotics, respectively, as used in several water-quality surveys conducted since 1999. In the offline tandem SPE method, normalized concentrations for the quinolone, macrolide, and sulfonamide antibiotics in spiked environmental samples averaged from 81 to 139 percent of the expected spiked concentrations. A modified standard-addition technique was developed to improve the quantitation of the tetracycline antibiotics, which had 'apparent' concentrations that ranged from 185 to 1,200 percent of their expected spiked concentrations in matrix-spiked samples. In the online SPE method, normalized concentrations for the quinolone, macrolide, sulfonamide, and tetracycline antibiotics in matrix-spiked samples averaged from 51 to 142 percent of their expected spiked concentrations, and the beta-lactam antibiotics in matrix-spiked samples averaged from 22 to 76 percent of their expected spiked concentration. Comparison of 44 samples analyzed by both the offline tandem SPE and online SPE methods showed 50 to 100 percent agreement in sample detection for overlapping analytes and 68 to 100 percent agreement in a presence-absence comparison for all analytes. The offline tandem and online SPE methods were compared to an independent method that contains two overlapping antibiotic compounds, sulfamethoxazole and trimethoprim, for 96 and 44 environmental samples, respectively. The offline tandem SPE showed 86 and 92 percent agreement in sample detection and 96 and 98 percent agreement in a presence-absence comparison for sulfamethoxazole and trimethoprim, respectively. The online SPE method showed 57 and 56 percent agreement in sample detection and 72 and 91 percent agreement in presence-absence comparison for sulfamethoxazole and trimethoprim, respectively. A linear regression with

  4. Quantitative determination of medroxyprogesterone acetate in plasma by liquid chromatography/electrospray ion trap mass spectrometry.

    Science.gov (United States)

    Kim, S M; Kim, D H

    2001-01-01

    A sensitive and rapid liquid chromatography/electrospray ion trap mass spectrometry (LC/MS/MS) method has been developed for the quantitative determination of medroxyprogesterone acetate (MPA) in human plasma. Plasma samples (1.0 mL) were simply extracted with pentane and the extracts were analyzed by HPLC with the detection of the analyte in the selective reaction monitoring (SRM) mode. The determination of MPA was accurate and reproducible, with a limit of quantitation of 0.05 ng/mL in plasma. The standard calibration curve for MPA was linear (r = 0.998) over the concentration range 0.05-6.0 ng/mL in human plasma. Analysis precision over the concentration range of MPA was lower than 18.8% (relative standard deviation, RSD) and accuracy was between 96.2 and 108.7%. PMID:11675672

  5. Development and validation of a fast and uniform approach to quantify β-lactam antibiotics in human plasma by solid phase extraction-liquid chromatography-electrospray-tandem mass spectrometry.

    Science.gov (United States)

    Colin, Pieter; De Bock, Lies; T'jollyn, Huybrecht; Boussery, Koen; Van Bocxlaer, Jan

    2013-01-15

    Monitoring of plasma antibiotic concentrations is necessary for individualization of antimicrobial chemotherapy dosing in special patient populations. One of these special populations of interest are the post-bariatric surgery patients. Until today, little is known on the effect of this procedure on drug disposition and efficacy. Therefore, close monitoring of antimicrobial plasma concentrations in these patients is warranted. A fast and uniform ultra-high-performance liquid chromatography (UPLC) method with tandem mass spectrometric detection (MS/MS) has been developed and qualified for the simultaneous quantification of β-lactam antibiotics in human plasma. Compounds included in this multi-component analysis are: amoxicillin, ampicillin, phenoxymethylpenicillin, piperacillin, cefuroxime, cefadroxil, flucloxacillin, meropenem, cefepime, ceftazidime, tazobactam, linezolid and cefazolin. After spiking of five different stable isotope labelled internal standards, plasma samples were prepared for UPLC-MS/MS analysis by mixed-mode solid phase extraction. The developed method was proven to be free of (relative) matrix effects and proved to be reliable for the quantification of 12 out of 13 β-lactam antibiotics. As a proof of concept the method has been applied to plasma samples obtained from a healthy volunteer treated with amoxicillin. The analytical method is suitable for use in a therapeutic drug monitoring setting, providing the clinician with reliable measurements on β-lactam antibiotic plasma concentrations in a timely manner.

  6. Determination of nine sensitizing disperse dyes in activated sludge by ultrasound-assisted liquid-liquid extraction-ultra-performance liquid chromatography-electrospray ionization-tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Linjun; Shi, Lili; Liu, Jining; Lv, Fenglan; Xu, Yanhua

    2016-01-01

    A method was developed on the basis of ultrasound-assisted liquid-liquid extraction ultra-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (ULLE-UPLC-ESI-MS/MS) to determine nine sensitizing disperse dyes in activated sludge. The samples were extracted using ULLE and separated through UPLC on an ACQUITY UPLCTM BEH C18 column with a gradient elution program of acetonitrile and acidified water (containing 2% acetonitrile, 0.2% formic acid, and 0.005 mol/L ammonium; pH 2.7) as the mobile phase. The samples were then identified and quantified through UPLC-ESI-MS/MS in a positive mode and multiple reaction monitoring. Results showed good linearity (10-1000 μg/L, 0.9934-0.9998), detection limit (0.08-2.17 μg/L), and quantification limit (0.27-7.38 μg/L) for the nine sensitizing disperse dyes, with recoveries ranging from 65.0 to 111.3%. The proposed method was applied to detect and determine the concentration of sensitizing disperse dyes in sludge samples obtained from various sewage treatment plants (six dyeing enterprises and one dye manufacturer). Three sensitizing disperse dyes were identified, and the lowest concentration detected was 10 μg/kg. PMID:26521175

  7. Improving detection sensitivity of amino acids in thyroid tissues by using phthalic acid as a mobile phase additive in hydrophilic interaction chromatography-electrospray ionization-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Highlights: • HILIC–ESI-MS/MS method was used to quantify 24 free AAs in human thyroid tissues. • Addition of 0.08 mM of phthalic acid to the eluent enhanced the sensitivity of AAs. • Narrowed peak shapes of AAs were achieved with phthalic acid in the mobile phase. • The mechanism for the signal intensity enhancement by phthalic acid was investigated. - Abstract: In this work, 0.08 mmol L−1 of phthalic acid was introduced as a mobile phase additive to quantify free amino acids (AAs) by hydrophilic interaction liquid chromatography (HILIC) coupled with electrospray ionization tandem mass spectrometry (ESI-MS/MS). The addition of phthalic acid significantly increased the signal intensity of protonated AA ions, resulting from the decrease of the relative abundance of AA sodium adducts. Meanwhile, the chromatographic peak shapes of AAs were optimized. As a consequence, there was a noticeable increase in the sensitivity of detection for AAs. The limits of detection (LOD) and quantification (LOQ) of the AAs ranged from 0.0500 to 20.0 ng mL−1 and from 0.100 to 50.0 ng mL−1, respectively, which were 4–50 times lower compared to the values measured without the addition of phthalic acid. The enhanced detection and separation of AAs were obtained by merely adding phthalic acid to the mobile phase without changing other conditions. Eventually, this simple method was validated and successfully applied to the analysis of twenty-four kinds of free AAs in human thyroid carcinoma and para-carcinoma tissues, demonstrating a significant increase of most AAs in thyroid carcinoma tissues (p < 0.05)

  8. Simultaneous determination of propofol and its glucuronide in whole blood by liquid chromatography-electrospray tandem mass spectrometry and the influence of sample storage conditions on the reliability of the test results.

    Science.gov (United States)

    Sørensen, Lambert K; Hasselstrøm, Jørgen B

    2015-05-10

    Propofol (2,6-diisopropylphenol) is commonly used as an anaesthetic agent but is also abused for recreational purposes. Several cases of fatalities involving self-administered propofol have been reported. For rapid quantification of propofol and propofol β-d-glucuronide (propofol G) in clinical and forensic cases, an ultra-performance liquid chromatography-tandem mass spectrometry method using pneumatically assisted electrospray ionisation has been developed. The technique has been validated on both ante-mortem and post-mortem human whole blood. The proteins in the blood samples were removed by the addition of a mixture of methanol and acetonitrile, and the extract was cleaned up by solid phase extraction. The extract was concentrated in dimethyl sulphoxide. The system was calibrated using matrix-matched calibrants combined with isotope dilution. The lower limits of quantification were 0.01 and 0.02mg/L for propofol and 0.02 and 0.04mg/L for propofol G in ante-mortem and post-mortem whole blood, respectively. The relative intra-laboratory reproducibility standard deviation was less than 10% at concentrations of 0.2mg/L or higher. The mean true extraction recovery was 85% for propofol and 81% for propofol G. The trueness of the propofol determination expressed as the relative bias of the test results was within ±6% at concentration levels of 0.01-8.5mg/L. Propofol was less stable in blood stabilised with a citrate-EDTA-fluoride mixture than in blood stabilised with an oxalate-fluoride mixture. The stability was lower at -20°C than at 5°C and -80°C. Propofol G did not show instability under the storage conditions tested.

  9. Improving detection sensitivity of amino acids in thyroid tissues by using phthalic acid as a mobile phase additive in hydrophilic interaction chromatography-electrospray ionization-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Wanshu [National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032 (China); Guan, Qing [Department of Head and Neck Surgery, Fudan University Shanghai Cancer Center (FUSCC), Shanghai 200032 (China); Department of Oncology, Shanghai Medical College, Fudan University, Shanghai 200032 (China); Sun, Tuanqi, E-mail: tuanqisun@163.com [Department of Head and Neck Surgery, Fudan University Shanghai Cancer Center (FUSCC), Shanghai 200032 (China); Department of Oncology, Shanghai Medical College, Fudan University, Shanghai 200032 (China); Cao, Yanjing [National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032 (China); Zhang, Li, E-mail: zhangli7488@sioc.ac.cn [National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032 (China); Guo, Yinlong, E-mail: ylguo@sioc.ac.cn [National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032 (China)

    2015-04-22

    Highlights: • HILIC–ESI-MS/MS method was used to quantify 24 free AAs in human thyroid tissues. • Addition of 0.08 mM of phthalic acid to the eluent enhanced the sensitivity of AAs. • Narrowed peak shapes of AAs were achieved with phthalic acid in the mobile phase. • The mechanism for the signal intensity enhancement by phthalic acid was investigated. - Abstract: In this work, 0.08 mmol L{sup −1} of phthalic acid was introduced as a mobile phase additive to quantify free amino acids (AAs) by hydrophilic interaction liquid chromatography (HILIC) coupled with electrospray ionization tandem mass spectrometry (ESI-MS/MS). The addition of phthalic acid significantly increased the signal intensity of protonated AA ions, resulting from the decrease of the relative abundance of AA sodium adducts. Meanwhile, the chromatographic peak shapes of AAs were optimized. As a consequence, there was a noticeable increase in the sensitivity of detection for AAs. The limits of detection (LOD) and quantification (LOQ) of the AAs ranged from 0.0500 to 20.0 ng mL{sup −1} and from 0.100 to 50.0 ng mL{sup −1}, respectively, which were 4–50 times lower compared to the values measured without the addition of phthalic acid. The enhanced detection and separation of AAs were obtained by merely adding phthalic acid to the mobile phase without changing other conditions. Eventually, this simple method was validated and successfully applied to the analysis of twenty-four kinds of free AAs in human thyroid carcinoma and para-carcinoma tissues, demonstrating a significant increase of most AAs in thyroid carcinoma tissues (p < 0.05)

  10. Highly sensitive isotope-dilution liquid-chromatography-electrospray ionization-tandem-mass spectrometry approach to study the drug-mediated modulation of dopamine and serotonin levels in Caenorhabditis elegans.

    Science.gov (United States)

    Schumacher, Fabian; Chakraborty, Sudipta; Kleuser, Burkhard; Gulbins, Erich; Schwerdtle, Tanja; Aschner, Michael; Bornhorst, Julia

    2015-11-01

    Dopamine (DA) and serotonin (SRT) are monoamine neurotransmitters that play a key role in regulating the central and peripheral nervous system. Their impaired metabolism has been implicated in several neurological disorders, such as Parkinson's disease and depression. Consequently, it is imperative to monitor changes in levels of these low-abundant neurotransmitters and their role in mediating disease. For the first time, a rapid, specific and sensitive isotope-dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of DA and SRT in the nematode Caenorhabditis elegans (C. elegans). This model organism offers a unique approach for studying the effect of various drugs and environmental conditions on neurotransmitter levels, given by the conserved DA and SRT biology, including synaptic release, trafficking and formation. We introduce a novel sample preparation protocol incorporating the usage of sodium thiosulfate in perchloric acid as extraction medium that assures high recovery of the relatively unstable neurotransmitters monitored. Moreover, the use of both deuterated internal standards and the multiple reaction monitoring (MRM) technique allows for unequivocal quantification. Thereby, to the best of our knowledge, we achieve a detection sensitivity that clearly exceeds those of published DA and SRT quantification methods in various matrices. We are the first to show that exposure of C. elegans to the monoamine oxidase B (MAO-B) inhibitor selegiline or the catechol-O-methyltransferase (COMT) inhibitor tolcapone, in order to block DA and SRT degradation, resulted in accumulation of the respective neurotransmitter. Assessment of a behavioral output of the dopaminergic system (basal slowing response) corroborated the analytical LC-MS/MS data. Thus, utilization of the C. elegans model system in conjunction with our analytical method is well-suited to investigate drug-mediated modulation of the DA and

  11. 液相色谱-串联质谱法测定生鲜乳中氯噻嗪残留量%Determination of Residue in Raw Milk by Liquid Chromatography-Electrospray Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    田素润; 蒋俊树; 丁磊

    2013-01-01

      A new method of ultra-performance liquid chromatography–electrospray ionization tandem mass spectrometry (LC–ESI–MS/MS) for the analysis of chlorothiazide in raw milk was developed. After degreasing purification, the sample was extracted by ethyl acetate, and then chlorothiazide in which was determined by LC–ESI–MS/MS. Separated analytes were determined using multiple reaction monitoring (MRM). The quantitative analysis of target compounds was performed by the external standard method. The result indicated that the calibration curves were linear in the range of 5–100μg/L for chlorothiazide. The correlation coefficients was 0.999. The quantification limit was 5μg/L (S/N=10). The recoveries of chlorothiazide at three spiked levels of 0.01,0.05,0.1 mg/kg were in the range of 86%–105%with RSDs (n=6) less than 8%.This method shortened the time of pre-treatment process, and the result was credible. It could satisfy the requirement of mass and fast analysis in the laboratory.%  采用液相色谱–串联质谱(HPLC–ESI–MS/MS)法测定生鲜乳中氯噻嗪含量。样品经去脂净化后,用乙酸乙酯提取,采用液相色谱–串联质谱法分析,多反应监测模式下(MRM)外标法定量。结果表明氯噻嗪的质量浓度与定量离子的峰面积在5~100μg/L范围内线性良好,线性相关系数为r=0.999,定量限为5μg/kg(S/N=10),在0.01,0.05,0.1 mg/kg的添加水平下,回收率在86%~105%之间,测定结果的相对标准偏差小于8%(n=6)。该方法前处理过程简便快捷,可满足实验室大量、快速分析的需求。

  12. The analysis of aqueous mixtures using liquid chromatography-electrospray mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, S.

    1999-02-12

    The focus of this dissertation is the use of chromatographic methods coupled with electrospray mass spectrometry (ES-MS) for the determination of both organic and inorganic compounds in aqueous solutions. The combination of liquid chromatography (LC) methods and ES-MS offers one of the foremost methods for determining compounds in complex aqueous solutions. In this work, LC-ES-MS methods are devised using ion exclusion chromatography, reversed phase chromatography, and ion exchange chromatography, as well as capillary electrophoresis (CE). For an aqueous sample, these LC-ES-MS and CE-ES-MS techniques require no sample preparation or analyte derivatization, which makes it possible to observe a wide variety of analytes as they exist in solution. The majority of this work focuses on the use of LC-ES-MS for the determination of unknown products and intermediates formed during electrochemical incineration (ECI), an experimental waste remediation process. This report contains a general introduction to the project and the general conclusions. Four chapters have been removed for separate processing. Titles are: Chapter 2: Determination of small carboxylic acids by ion exclusion chromatography with electrospray mass spectrometry; Chapter 3: Electrochemical incineration of benzoquinone in aqueous media using a quaternary metal oxide electrode in the absence of a soluble supporting electrolyte; Chapter 4: The determination of electrochemical incineration products of 4-chlorophenol by liquid chromatography-electrospray mass spectrometry; and Chapter 5: Determination of small carboxylic acids by capillary electrophoresis with electrospray mass spectrometry.

  13. Determination of Tetracyclin, Oxytetracycline and Roxithromycin in Water Samples by Solid Phase Extraction-Ultra Performance Liquid Chromatography Electrospray Tandem Mass Spectrometry%固相萃取-超高效液相色谱三重四级杆质谱联用法测定水中四环素、土霉素及罗红霉素

    Institute of Scientific and Technical Information of China (English)

    尹燕敏

    2013-01-01

    A rapid analytical method for simultaneous determination of tetracyclin, oxytetracycline and roxithromycin in water sample was developed. Water samples were purified and concentrated by solid phase extraction(SPE), then analyzed by ultra performance liquid chromatography electrospray tandem mass spectrometry(UPLC-MS/MS). Using formic acid and acetonitrile as the mobile phase, the three antibiotics were separated within 5 min. The limit of determination for anlytes were 0.08-0.35 ng/L with the relative standard deviation of 1.4%-5.6%. The recoveries of the antibiotics were in the range of 82.5%-114%for blank and 71.5%-126%for real samples.%建立了固相萃取-超高效液相色谱三重四级杆质谱联用法同时测定水中的罗红霉素、四环素和土霉素残留。水样经过固相萃取纯化、富集,液质联用分析,采用甲酸溶液和乙腈作为流动相,在5 min内完成对3种目标化合物的分析,3种目标化合物的方法检出限介于0.08~0.35 ng/L之间,测定结果的相对标准偏差为1.4%~5.6%,空白样品和实际样品的加标回收率分别为82.5%~114%,71.5%~126%。

  14. Sheath liquid effects in capillary high-performance liquid chromatography-electrospray mass spectrometry of oligonucleotides.

    Science.gov (United States)

    Huber, C G; Krajete, A

    2000-02-18

    Fused-silica capillary columns of 200 microm inner diameter were packed with micropellicular, octadecylated, 2.3 microm poly(styrene-divinylbenzene) particles and applied to the separation of oligonucleotides by ion-pair reversed-phase high-performance liquid chromatography. Oligonucleotides were eluted at 50 degrees C with gradients of 3-13% acetonitrile in 50 mM triethylammonium bicarbonate. Addition of sheath liquid to the column effluent allowed the detection of oligonucleotides by electrospray ionization mass spectrometry using full-scan data acquisition with a detectability comparable to that obtained with UV detection. The signal-to-noise ratios with different sheath liquids increased in the order isopropanolmass spectra mainly because of increased background noise. Only a few charge states were observed in the mass spectra of oligonucleotides because of charge state reduction due to the presence of carbonic acid in the eluent. With triethylammonium hydrogencarbonate as chromatographic eluent and acetonitrile as sheath liquid, very few cation adducts of oligonucleotides were observed in the mass spectra. However, the presence of small amounts of monopotassium adducts enabled the calculation of the charge state of multiply charged ions. With acetonitrile as sheath liquid, 710 amol of a 16-mer oligonucleotide were detected using selected ion monitoring data acquisition with a signal-to-noise ratio of 3:1. Finally, capillary ion-pair reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry was

  15. Quantitation of repaglinide and metabolites in mouse whole-body thin tissue sections using droplet-based liquid microjunction surface sampling-high-performance liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Chen, Weiqi; Wang, Lifei; Van Berkel, Gary J; Kertesz, Vilmos; Gan, Jinping

    2016-03-25

    Herein, quantitation aspects of a fully automated autosampler/HPLC-MS/MS system applied for unattended droplet-based surface sampling of repaglinide dosed thin tissue sections with subsequent HPLC separation and mass spectrometric analysis of parent drug and various drug metabolites were studied. Major organs (brain, lung, liver, kidney and muscle) from whole-body thin tissue sections and corresponding organ homogenates prepared from repaglinide dosed mice were sampled by surface sampling and by bulk extraction, respectively, and analyzed by HPLC-MS/MS. A semi-quantitative agreement between data obtained by surface sampling and that by employing organ homogenate extraction was observed. Drug concentrations obtained by the two methods followed the same patterns for post-dose time points (0.25, 0.5, 1 and 2 h). Drug amounts determined in the specific tissues was typically higher when analyzing extracts from the organ homogenates. In addition, relative comparison of the levels of individual metabolites between the two analytical methods also revealed good semi-quantitative agreement. PMID:26589943

  16. Validation of a Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry Method for Determination of All-Trans Retinoic Acid in Human Plasma and Its Application to a Bioequivalence Study

    Directory of Open Access Journals (Sweden)

    Jing-Bo Peng

    2014-01-01

    Full Text Available A sensitive, reliable and specific LC-MS-MS method was developed and validated for the identification and quantitation of all-trans retinoic acid (ATRA in human plasma. Acitretin was used as the internal standard (IS. After liquid-liquid extraction of 500 μL plasma with methyl tert-butyl ether (MTBE, ATRA and the IS were chromatographed on a HyPURITY C18 column (150 mm × 2.1 mm, 5 μm with the column temperature set at 40 °C. The mobile phase was consisted of 40% phase A (MTBE–methanol–acetic acid, 50:50:0.5, v/v and 60% phase B (water–methanol–acetic acid, 50:50:0.5, v/v with a flow rate of 0.3 mL/min. The API 4000 triple quadrupole mass spectrometer was operated in multiple reaction monitoring (MRM mode via the positive electrospray ionization interface using the transition m/z 301.4 → 123.1 for ATRA and m/z 326.9 → 177.1 for IS, respectively. The calibration curve was linear over the range of 0.45–217.00 ng/mL (r ≥ 0.999 with a lower limit of quantitation (LLOQ of 0.45 ng/mL. The intra- and inter-day precisions values were below 8% relative standard deviation and the accuracy was from 98.98% to 106.19% in terms of relative error. The validated method was successfully applied in a bioequivalence study of ATRA in Chinese healthy volunteers.

  17. A simplified procedure for the analysis of formoterol in human urine by liquid chromatography-electrospray tandem mass spectrometry: application to the characterization of the metabolic profile and stability of formoterol in urine.

    Science.gov (United States)

    Mazzarino, Monica; de la Torre, Xavier; Fiacco, Ilaria; Pompei, Chiara; Calabrese, Fabiana; Botrè, Francesco

    2013-07-15

    Since 1992, formoterol is included in the prohibited list of doping substances and methods, presently reviewed and updated by the World Anti-Doping Agency. Recently a threshold value of 40ng/mL has been established to differentiate between the prohibited (oral) and the permitted (inhalatory) administration of formoterol to athletes. This paper considers the urinary excretion profile of formoterol and its main metabolites after inhalation of different doses of two of the most used medicaments, available in Italy, containing formoterol fumarate bihydrate (12 and 36μg twice a day of Foradil(®) or 9 and 27μg twice a day of Symbicort(®)), focusing also on the effects, on the measured levels of formoterol, of potential alteration processes (thermal and/or microbiological) that may take place after the collection of the urine samples. Urine sample preparation included an enzymatic hydrolysis and a dilution step. Detection of analytes was performed by a newly developed and validated direct LC-ESI-MS/MS procedure, using a triple quadrupole mass spectrometer under positive ion electro-spray ionization conditions and selected reaction monitoring acquisition mode. The results showed the capability and suitability of the direct LC-ESI-MS/MS analysis for the quantitative confirmation analysis of formoterol in urine samples. The data from the analysis of the urine samples obtained in the excretion studies showed that formoterol is excreted mainly as unmodified drug and to a lesser degree as O-demethylated metabolite. The urinary levels of formoterol (40-60%) and its metabolites (O-demethylated metabolite 5-25%; glucuronide metabolites 25-40%) vary significantly depending both on the administered drug formulation and the subject tested. The maximum urinary concentration reached in this study was 15ng/mL (free+glucuronide), that is significantly lower than the threshold value fixed to report an adverse analytical finding. Finally, our results also showed that formoterol is

  18. 固相萃取-超高效液相色谱-电喷雾串联质谱法检测梨树叶中熊果苷%Quantitative and qualitative determination of arbutin in pear leaves by ultra performance liquid chromatography-electrospray tandem mass spectrometry coupled with solid phase extraction

    Institute of Scientific and Technical Information of China (English)

    赵洁; 何强; 孔祥虹; 李建华; 乐爱山; 姚秉华

    2011-01-01

    建立了固相萃取净化、超高效液相色谱-串联质谱检测梨树叶中熊果苷含量的方法.将粉碎的梨树叶样品用甲醇提取,ENVITM-18固相萃取柱净化,超高效液相-电喷雾串联四级杆质谱检测,外标法定量.测定时用 Acquity UPLC HSS T3 色谱柱(50 mm×2.1 mm,1.8μm)分离,甲醇-水(V/V,7+93)洗脱,多重反应监测 (MRM) 模式检测,定量离子对为m/z 271.2>107.8,定性离子对为 m/z 271.2>160.9.熊果苷的最低检出限为 0.05μg/mL,在0.1~10.0μg/mL 的范围内标准溶液的峰面积与浓度呈良好的线性关系,回收率为93.2%~106.5%,相对标准偏差低于5.9%.%An ultra performance liquid chromatography-electrospray tandem mass spectrometries (UPLC-ESI-MS/MS) method was developed for the quantitative and qualitative determination of arbutin in pear leaves. The full powdered pear leaves were extracted with methanol and purified by ENVITM-18 SPE columns. Analysis was performed on UPLC-ESI-MS/MS and quantitation was carried out using an external standard method. Separation of the samples was performed on an acquity UPLC HSS T3 column (50 mm × 2. 1 mm, 1.8 μm) using methanolwater(V/V, 7 + 93 ) as mobile phase. MS/MS was performed with multiple reaction monitoring (MRM) mode using m/z 271.2 > 107. 8 as quantitative ion pair and m/z 271.2 > 160. 9 as qualitative ion pair. The detection limit of arbutin was 0. 05 μg/mL. The method showed good linear relationship in the range of 0. 1 ~ 10. 0 μg/mL.

  19. 超高效液相色谱-电喷雾串联质谱法测定塑料成品中的三甲基氯化锡%Determination of trimethyltin in plastic product by using ultra high performance liquid chromatography electrospray ionization tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    陈慧玲; 许欣欣; 毛丽莎; 刘红河; 陆少游

    2016-01-01

    目的:建立塑料成品中三甲基氯化锡(TMT)的超高效液相色谱-串联质谱联用测定法(UPLC-MS/MS)。方法塑料样品用乙酸乙酯提取,洗脱液在40℃水浴下氮气吹干;残渣用流动相溶解,旋涡混匀60s,过0.22μm微孔滤膜,经C18色谱柱完成分离,串联质谱仪上采用多反应监测正离子模式测定三甲基氯化锡,外标法定量。结果三甲基氯化锡在1.0~100.0μg/L 范围内线性关系良好(相关系数 r=0.9997),检出限0.2μg/L。在2.0、10.0和50.0μg/L 3个添加水平范围的RSD小于8.0%,样品加标回收率为88.5%~93.4%。结论建立的超高效液相色谱-串联质谱联用法测定塑料成品中三甲基氯化锡的方法快速简单、准确有效。%Objective An ultra-high performance liquid chromatography eclectrospray ionization tandem mass spectrometry (UPLC-MS/MS) method was developed to determine trimethyltin (TMT) in plastic product. Methods TMT was extracted from plastic product by ethyl acetate, the elute was evaporated to dryness with nitrogen in 40℃ water bath, redissolved with 1ml of moble phase solution, vortexed for 60 s and filtered with 0.22 μm membrane. The filtrate was detected by UPLC-MS/MS in positive ion electrospray and MRM mode with a UPLC C18 column as separation column, and quantified with external standard substances. Results TMT was linear in the range of 1.0~100.0 μg/L with correlation coefficient of 0.9997. The relative standard derivations (RSD) at three levels (2.0 μg/L、10.0 μg/L and 50.0 μg/L) were lower than 8.0%, and the recovery rate was from 88.5% to 93.4%. Conclusion The method of liquid chromatography-electrospray tandem mass spectrometry is simple, reliable and accurate, that adapts to determinate TMT in plastic product.

  20. Determination of 5 polyether antibiotics in chicken tissues by liquid chromatography-electrospray ionization tandem mass spectrometry%液相色谱-电喷雾串联质谱法检测鸡组织中5种聚醚类药物残留

    Institute of Scientific and Technical Information of China (English)

    梁春来; 程林丽; 沈建忠; 张玉洁; 张素霞

    2009-01-01

    A liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI MS/MS) method for the determination of 5 polyether antibiotics (lasalocid, salinomycin, mon-ensin, narasin and maduramicin) in chicken tissues was developed. The polyether antibiotics were extracted from chicken tissues with methanol. The extract was evaporated to dry, and re-dissolved in hexane, then cleaned up on a Sep-Pak Silica solid-phase extraction cartridge. The target drugs were eluted with 6 mL methylene chloride-methanol (90= 10, v/v), and the eluate was collected and dried under a gentle stream of nitrogen gas, then the residue was dissolved with 1 mL acetonitrile (containing 0. 1% formic acid) and analyzed by LC-MS/MS. The LC sep-aration was performed on a Symmetry Shield reversed phase C18 bonded silica column with acetonitrile (containing 0. 1% formic acid) - 0. 1% formic acid (97:3, v/v) as mobile phase. The quantification was carried out by positive electrospray ionization and multiple reaction mo-nitoring (MRM) mode. The validation was carried out on spiked chicken muscle (spiked at 0. 1 -1 500 μg/kg) and chicken liver (spiked at 0. 2-4 500 μg/kg), the average recoveries of tar-get drugs ranged from 71. 6%-99. 1% with intra-day relative standard deviations (RSDs) of 3. 2%-10. 7% and inter-day RSDs of 4. 6%-14. 7%. The limits of quantification ( LOQs) in chicken muscle and liver were 0. 1 - 1. 0 μg/kg. The results demonstrated that the sensitivity, accuracy and precision of this method meet the requirements of veterinary drug residue analy-sis. The method is applicable to detect 5 polyether antibiotics in chicken muscle and liver.%建立了鸡组织中聚醚类药物多残留检测的高效液相色谱-电喷雾串联质谱方法.采用甲醇提取鸡组织中的拉沙洛菌素、盐霉素、莫能菌素、甲基盐霉素和马杜霉素,经硅胶柱净化,以乙腈(含0.1%甲酸)-0.1%甲酸水溶液(体积比为97∶3)为流动相,Symmetry Shield RP18作为色谱分

  1. Determination of citric acid in wine samples by ion chromatography-electrospray ionization tandem mass spectrometry (IC/MS)%离子色谱-质谱联用(IC/MS)法检测葡萄酒样品中的柠檬酸

    Institute of Scientific and Technical Information of China (English)

    周海波; 陈林; 闫永利

    2013-01-01

    目的:建立了离子色谱-质谱联用技术测定葡萄酒样品中柠檬酸的分析方法。方法以高容量、强亲水性的IonPac AS20型阴离子交换柱为分析柱, EGC在线产生梯度浓度KOH为淋洗液,淋洗液经捕获柱、抑制器成水后将样品带入质谱检测器。ESI-SIM监测模式监控柠檬酸根离子(m/z=191),并以峰面积进行定量。结果该方法对柠檬酸的检出限(S/N=3)为17.6μg/L,且柠檬酸浓度在50~1000μg/L范围内具有良好的线性,线性相关系数r=0.9992。200μg/L标准溶液重复进样8次,柠檬酸峰面积的相对标准偏差即精密度为0.77%。运用该方法测定市售5种不同品牌葡萄酒样品中柠檬酸的含量,并对样品加标回收,得回收率大于95%。结论该方法可以满足葡萄酒中柠檬酸定量分析的要求,且有效改善了分析的灵敏度和准确性。%Objective To establish a rapid method for determination of citric acid in wine samples by ion chromatography-electrospray ionization tandem mass spectrometry (IC/ESI-MS) in the negative ESI and se-lected ion monitor (SIM) mode. Methods Citric acid was separated by high capacity and hydroxide selective column IonPac AS20 with KOH eluent generated from EGC. Peak area of citrate ion (m/z=191) was monitored for quantifying. Results The limit of detection was 17.6μg/L for citric acid. A linear calibration was obtained over the range from 50 to 1000μg/L with a correlation coefficient of 0.9992. The relative standard deviation for 8 injections of standard solution (200 μg/L) was 0.77%. This method was applied to detect the citric acid in different kinds of wine samples which were purchased in market, and the rates of recovery were higher than 95%. Conclusion The method could meet the requirements of quantitative analysis of citric acid in wine samples, and also could improve the sensitivity and accuracy of the analysis.

  2. 液相色谱-串联质谱法测定河豚鱼和鳗鱼中9种青霉素类抗生素%Determination of 9 penicillins in Fugu and eel by high pressure liquid chromatography-electrospray tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    李学民; 曹彦忠; 张进杰; 母健; 王蕾; 王贺琴

    2013-01-01

      目的建立高压液相色谱-电喷雾串联质谱(HPLC-MS-MS)同时测定河豚鱼和鳗鱼中9种青霉素残留量的检测方法。方法样品经乙腈-氨水溶液提取后,用C18色谱柱分离,乙腈-乙酸为流动相梯度洗脱,最后采用液相色谱-电喷雾串联质谱在正离子多反应监测模式下测定。结果在1.0~20μg/kg(LOQ~10LOQ)范围时,方法线性关系良好,相关系数大于0.999。在LOQ、2 LOQ、4 LOQ、10 LOQ四个添加水平下青霉素的回收率在81.4%~109.7%之间,相对标准偏差在2.81%~7.12%之间,方法检出限是:萘夫西林、青霉素 G、哌拉西林、青霉素 V、苯唑西林为1.0μg/kg;阿莫西林、氨苄西林、氯唑西林、双氯西林为2.0μg/kg。结论此方法灵敏度高,准确性好,适用于水产品中青霉素的定量检测。%Objective A sensitive method was developed for the determination of 9 penicillins in Fugu and eel by high pressure liquid chromatography-electrospray tandem mass spectrometry (HPLC-MS/MS). Methods Samples were extracted with acetonitrile-ammonia water, separated on a C18 column by gradient elution with acetonitrile and 0.3%acetic acid solution as mobile phase. Identification was achieved by electro-spray ionization(ESI) in positive mode. Results The method showed a good linearity over the range of 1.0~20μg/kg for 9 compounds of penicillins with r≥0.999. Recoveries of 9 penicillins were between 81.4% and 109.7% (n=6) at spiked levels of LOQ, 2LOQ, 4LOQ and 10LOQ with relative standard deviations (RSD of 2.81%∼7.12%). The limit of quantitation(LOQ) for nafcillin, penicillin G, piperacillin, penicillin V and oxacil-lin were 1.0 μg/kg and the LOQ for amoxicillin, ampicillin, cloxacillin and dicloxacillin were 2.0 μg/kg. Conclusion This method is sensitive and accurate, and it is suitable for the analysis of 9 penicillins in aquatic products.

  3. Identification of Phenylethanoid Glycosides in Plant Extract of Plantago asiatica L. by Liquid Chromatography-Electrospray Ionization Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    LI,Li; LIU,Chunming; LIU,Zhiqiang; TSAO,Rong; LIU,Shuying

    2009-01-01

    The present work describes a liquid chromatography-electrospray ionization mass spectrometry(LC-ESI-MS)method for rapid identification of phenylethanoid glycosides in plant extract from Plnmgo asiatica L.By using a binary mobile phase system consisting of 0.2% acetic acid and acetonitrile under gradient conditions,a good sepa-ration was achieved on a reversed-phase C18 column.The[M-H] ions,the molecular weights,and the fragmentions of phenvlethanoid glycosides were obtained in the negative ion mode using LC-ESI-MS.The identification of the phenylethanoid glycosides(peaks 1-3) in the extract of P. asiatica L.was based on matching their retention time.the detection of molecular ions.and the fragment ions obtained by collision-induced dissociation(CID)ex-periments with those of the authentic standards and data reported in the literature.

  4. Enantiomeric quantification of (S)-(+)-methamphetamine in urine by an immunoaffinity column and liquid chromatography-electrospray-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lua, Ahai C. [Department of Laboratory Medicine and Biotechnology and Graduate Institute of Medical Biotechnology, Tzu Chi University, 701, Chung Yang Road Section 3, Hualien, 970, Taiwan (China); Sutono, Yenny [Department of Laboratory Medicine and Biotechnology and Graduate Institute of Medical Biotechnology, Tzu Chi University, 701, Chung Yang Road Section 3, Hualien, 970, Taiwan (China); Chou, T.-Y. [Department of Laboratory Medicine and Biotechnology and Graduate Institute of Medical Biotechnology, Tzu Chi University, 701, Chung Yang Road Section 3, Hualien, 970, Taiwan (China)]. E-mail: cty@mail.tcu.edu.tw

    2006-08-18

    A method using an immunoaffinity column (IAC) and liquid chromatography-electrospray ionization mass spectrometry (LC/MS) for on-line detecting the presence of MA in the effluent was developed for the quantitative and enantiomeric determination of (S)-(+)-methamphetamine (D-MA) in urine. The IAC was made in our laboratory and utilized in the LC/MS to simultaneously extract and separate enantiomers of MA from urine samples. An aqueous ammonium acetate buffer was used as the mobile phase. Urine samples were spiked with racemic deuterated methamphetamine (MA-d{sub 14}) as internal standard (IS), filtered through a membrane, and injected into the LC/MS without any further pre-treatment. Protonated molecular ion of MA and MA-d{sub 14} (m/z 150 and 164) were isolated and further fragmented, the respective product ions, m/z 119 and 130, were collected for quantitative determination. This is an improvement of our previous method (A.C. Lua, Tsong-Yung Chou, J. Chromatogr. A 967 (2002) 191). In the previous method, MA was separated with HPLC, the efflux was fractionated and each fraction was either determined with an immunoassay or GC/MS. Monitoring of MA in the efflux is tedious and time consuming. Urine samples spiked with different concentrations of D-MA were measured by this method. A linear relationship exists in the 150-1050 ng/mL range, and the detection limit (defined as signal-to-noise ratio 3) of D-MA was determined to be 18 ng/mL. The linearity of the method for D-MA can be described by the equation (Y = 1.415 x 10{sup -3} X + 0.034, correlation coefficient: r {sup 2} = 0.999). Within run, accuracy and precision (n = 6, relative error: -7.2 to +4.0% and relative standard deviation: 3.8-9.3%) of the method are fairly good.

  5. Tools to discover anionic and nonionic polyfluorinated alkyl surfactants by liquid chromatography electrospray ionisation mass spectrometry

    DEFF Research Database (Denmark)

    Trier, Xenia; Granby, Kit; Christensen, Jan H.

    2011-01-01

    A tiered approach is proposed for the discovery of unknown anionic and nonionic polyfluorinated alkyl surfactants (PFASs) by reversed phase ultra high performance liquid chromatography (UHPLC) – negative electrospray ionisation – quadrupole time of flight mass spectrometry (UHPLC......–ESI−–QTOF–MS). The chromatographic separation, ionisation and detection of PFASs mixtures, was achieved at high pH (pH=9.7) with NH4OH as additive. To distinguish PFASs from other chemicals we used the characteristic negative mass defects of PFASs, their specific losses of 20Da (HF) and the presence of series of chromatographic...

  6. Simultaneous quantitative analysis of metabolites using ion-pair liquid chromatography-electrospray ionization mass spectrometry

    NARCIS (Netherlands)

    Coulier, L.; Bas, R.; Jespersen, S.; Verheij, E.; Werf, M.J. van der; Hankemeier, T.

    2006-01-01

    We have developed an analytical method, consisting of ion-pair liquid chromatography coupled to electrospray ionization mass spectrometry (IP-LC-ESI-MS), for the simultaneous quantitative analysis of several key classes of polar metabolites, like nucleotides, coenzyme A esters, sugar nucleotides, an

  7. Liquid chromatography/electrospray ionization mass spectrometric characterization of Harpagophytum in equine urine and plasma.

    Science.gov (United States)

    Colas, Cyril; Garcia, Patrice; Popot, Marie-Agnès; Bonnaire, Yves; Bouchonnet, Stéphane

    2006-01-01

    A method has been developed for the analysis and characterization in equine urine and plasma of iridoid glycosides: harpagide, harpagoside and 8-para-coumaroyl harpagide, which are the main active principles of Harpagophytum, a plant with antiinflammatory properties. The method involves liquid chromatography coupled with positive electrospray ionization mass spectrometry. The addition of sodium or lithium chloride instead of formic acid in the eluting solvent has been studied in order to enhance the signal and to modify the ion's internal energy. Fragmentation pathways and associated patterns are proposed for each analyte. A comparison of three types of mass spectrometer: a 3D ion trap, a triple quadrupole and a linear ion trap, has been conducted. The 3D ion trap was selected for drug screening analysis whereas the linear ion trap was retained for identification and quantitation analysis. PMID:17044124

  8. Quantitative determination of capsaicinoids by liquid chromatography-electrospray mass spectrometry.

    Science.gov (United States)

    Thompson, Robert Q; Phinney, Karen W; Welch, Michael J; White, Edward

    2005-04-01

    Eight naturally occurring capsaicinoids have been determined in Capsicum by use of high-purity standards, with norcapsaicin as an internal standard. The solid standards were rigorously checked for purity. The sensitivity of electrospray ionization (ESI), atmospheric-pressure chemical ionization (APCI), and coordination ion-spray (CIS; with silver) toward the capsaicinoids were measured and compared. The highest sensitivity was found for positive-ion ESI. Method validation of the liquid chromatography-ESI-mass spectrometry (LC-ESI-MS) determination is reported, including tests for repeatability (4%), detection limit (5 pg injected), linear range (20-6 ng injected), quantitation (excellent linearity; pepper fruits were quantified. PMID:15803309

  9. Liquid Chromatography-Electrospray Ionization Mass Spectrometry Method for Determination of Protopanaxadiol in Rat Plasma

    Institute of Scientific and Technical Information of China (English)

    WU Yi; TENG Guo-sheng; LIANG Yong-tao; ZHONG Da-fang; LIU Bing

    2009-01-01

    A simple, rapid and sensitive method for the determination of protopanaxadiol in rat plasma with ginse-noside Rh2 as internal standard was developed and validated. The analyte and internal standard were extracted from plasma with ether-dichloromethane(3:2, volume ratio) and then were analyzed by reversed-phase HPLC on a short Zorbax Extend C_(18) column(50 mm×2.1 mm, 3.5 μm i.d.) eluted with a mobile phase consisting of acetoni-trile/methanol 0.10 mmol/L ammonium acetate(45:45:10, volume ratio) at 0.4 mL/min. Detection was performed on an Applied Biosystems Sciex API 4000 mass spectrometer set at unit resolution in the multiple reaction monitoring mode. Electrospray ionization was used for ion production. The assay method shows linear over a range of 5-2000 ng/mL and intra- and inter-day precisions over this range were <10.0% with accuracy ranged from 86.3% to 114.1%. The limit of detection was 500 pg/mL in the plasma. The method was successfully applied to a preclinical pharmaco-kinetic study of protopanaxadiol(17.5 mg/kg) administered as a single oral dose.

  10. Determination of synthetic ferric chelates used as fertilizers by liquid chromatography-electrospray/mass spectrometry in agricultural matrices.

    Science.gov (United States)

    Alvarez-Fernández, Ana; Orera, Irene; Abadía, Javier; Abadía, Anunciación

    2007-01-01

    A high-performance liquid chromatography-electrospray ionization/mass spectrometry (time of flight) method has been developed for the simultaneous determination of synthetic Fe(III)-chelates used as fertilizers. Analytes included the seven major Fe(III)-chelates used in agriculture, Fe(III)-EDTA, Fe(III)-DTPA, Fe(III)-HEDTA, Fe(III)-CDTA, Fe(III)-o,oEDDHA, Fe(III)-o,pEDDHA, and Fe(III)-EDDHMA, and the method was validated using isotope labeled (57)Fe(III)-chelates as internal standards. Calibration curves had R values in the range 0.9962-0.9997. Limits of detection and quantification were in the ranges 3-164 and 14-945 pmol, respectively. Analyte concentrations could be determined between the limits of quantification and 25 muM (racemic and meso Fe(III)-o,oEDDHA and Fe(III)-EDDHMA) or 50 muM (Fe(III)-EDTA, Fe(III)-HEDTA, Fe(III)-DTPA, Fe(III)-CDTA and Fe(III)-o,pEDDHA). The average intraday repeatability values were approximately 0.5 and 5% for retention time and peak area, respectively, whereas the interday repeatability values were approximately 0.7 and 8% for retention time and peak area, respectively. The method was validated using four different agricultural matrices, including nutrient solution, irrigation water, soil solution, and plant xylem exudates, spiked with Fe(III)-chelate standards and their stable isotope-labeled corresponding chelates. Analyte recoveries found were in the ranges 92-101% (nutrient solution), 89-102% (irrigation water), 82-100% (soil solution), and 70-111% (plant xylem exudates). Recoveries depended on the analyte, with Fe(III)-EDTA and Fe(III)-DTPA showing the lowest recoveries (average values of 87 and 88%, respectively, for all agricultural matrices used), whereas for other analytes recoveries were between 91 and 101%. The method was also used to determine the real concentrations of Fe(III)-chelates in commercial fertilizers. Furthermore, the method is also capable of resolving two more synthetic Fe(III)-chelates, Fe

  11. Investigation of alkaloids in Coptids Rhizoma by reversed-phase high performance liquid chromatography-electrospray ionization ion trap tandem mass spectrometry%黄连生物碱的反相高效液相-电喷雾离子阱串联质谱的研究

    Institute of Scientific and Technical Information of China (English)

    王道武; 庞雪; 赵全成; 张龙

    2011-01-01

    The alkaloids in Coptids Rhizoma were studied by reversed-phase HPLC-electrospray ionization ion trap tandem mass spectrometry. The conditions of HPLC separation were optimized with mobile phase comprised of 70% acetonitrile and 30% H2O(contained of 2 mmol/L triethylamine) at a flow rate of 0.5 mL/min and column temperature was 30 ℃. The main compounds of berberine, jatrorrhizine, Palmatine, coptisine and the trace of epiberberine and magnoflorine were detected with the electrospray ionization ion trap tandem mass spectrometry. The structures of berberine and epiberberine were confirmed by the CID spectra. Magnoflorine was studied by electrospray ionization ion trap tandem mass spectrometry,and the fragmentation mechanism was discussed.%采用反相高效液相-电喷雾离子阱串联质谱法对由乙醇提取的黄连生物碱进行了研究.优化出了反相高效液相色谱分离黄连生物碱的条件:流动相为V(乙腈):V(H2O)(三乙胺2 mmol/L)=30:70;柱温为30℃;流速为0.5 mL/min,并结合电喷雾串联质谱检测出了黄连生物碱中的小檗碱、药根碱、巴马汀、黄连碱以及微量的表小檗碱和木兰碱,利用小檗碱和表小檗碱的CID数据分析确证了它们的结构,并利用电喷雾离子阱串联质谱研究了木兰碱在正离子检测方式的多级串联质谱,对其碎裂机理进行了解释.

  12. High-performance liquid chromatography-electrospray ionization-tandem mass spectrometry method for determination of active ingredients in technical zhongshengmycin%中生菌素原药有效成分高效液相色谱-串联质谱分析方法的建立

    Institute of Scientific and Technical Information of China (English)

    乔港; 魏少鹏; 姬志勤

    2012-01-01

    建立了采用高效液相色谱-串联质谱(HPLC-ESI-MS/MS)分析中生菌素(zhongshengmycins)原药中各有效成分(链丝菌素A~F)的方法.原药用去离子水超声辅助提取后经离心过滤,反相离子对高效液相色谱分离,二级质谱检测,标准样品定量离子外标法定量.结果表明:在15.63~500μg/mL质量浓度范围内,中生菌素原药各组分的仪器响应值与进样质量浓度之间呈良好的线性关系,相关系数R2>0.990 5;方法具有较好的精密度和准确度,6次重复进样,其相对标准偏差(RSD)在0.33% ~ 1.96%之间;在0.1、0.5和1μg/mg 3个添加水平下,各组分的回收率在98.2%~101.1%之间.样品实测结果表明:供试原药中链丝菌素D的含量最高,为297.65 μg/g;其次是链丝菌素B、C和F,含量分别为247.77、285.64和115.92 μg/g;链丝菌素A和E的含量较低,分别为15.63和19.60 μg/g.该方法能满足中生菌素原药中各有效成分定性及定量分析的要求.%A reliable method for determination of active ingredients in technical zhongshengmycin material was established using high-performance liquid chromatography coupled to tandem mass spectrometry (HPLC-ESI-MS/MS). The active ingredients in technique material were extracted by the ultrasound-assisted method, and then the aqueous extract was cleaned up by centrifugation and filtration. After separated by reverse-phase ion-pair chromatography, the characteristic MS/MS ions were detected by mass spectrometer and quantified with external standard method. A good linear relationship between response and concentration was obtained in the range of 15.63 -500 μg/mL,and its correlation coefficient was above 0.990 5. The relative standard derivations for different ingredients were in the range of 0. 33% - 1. 96%. The recovery rates for different ingredients were 98. 2% -101. 1% in the spiking levels of 0. 1,0. 5 and 1 μg/mg. The contents of streptothricins D,B,C,F,A and E in the tested technical

  13. Metabolic profile of naringenin in the stomach and colon using liquid chromatography/electrospray ionization linear ion trap quadrupole-Orbitrap-mass spectrometry (LC-ESI-LTQ-Orbitrap-MS) and LC-ESI-MS/MS.

    Science.gov (United States)

    Orrego-Lagarón, Naiara; Vallverdú-Queralt, Anna; Martínez-Huélamo, Miriam; Lamuela-Raventos, Rosa M; Escribano-Ferrer, Elvira

    2016-02-20

    Several biological activities (antioxidant, anti-inflammatory, anticarcinogenic) are attributed to naringenin (NAR)-a predominant flavonoid of citrus fruit and tomato-despite its low bioavailability after ingestion. NAR undergoes extensive metabolism when crossing the gastrointestinal tract, resulting in enteric, hepatic and microbial metabolites, some of them with recognized beneficial effects on human health. This study sought to provide new insights into the metabolism of NAR in regions of the gastrointestinal tract where it has been less studied: the stomach and colon. With this purpose, liquid chromatography coupled with an electrospray ionization hybrid linear ion trap quadrupole Orbitrap mass spectrometry technique (LC-ESI-LTQ-Orbitrap-MS) was used for an accurate identification of NAR metabolites, and liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) on a triple quadrupole was used for their identification and quantification. The combination of both analytical techniques provided a broader metabolic profile of NAR. As far as we know, this is the first in-depth metabolic profiling study of NAR in the stomach of mice. Three of the metabolites determined using the LC-LTQ-Orbitrap could not be identified by LC-ESI-MS/MS in stomach perfusion samples: apigenin, 3-(4-hydroxyphenyl) propionic acid and phloroglucinol. The number of colonic metabolites determined using the LTQ-Orbitrap-MS was more than twice the number identified by LC-ESI-MS/MS. PMID:26698229

  14. Application of a rapid and selective method for the simultaneous determination of carebastine and pseudoephedrine in human plasma by liquid chromatography-electrospray mass spectrometry for bioequivalence study in Korean subjects.

    Science.gov (United States)

    Lee, Myung-Jae; Lee, Heon-Woo; Kang, Jong-Min; Seo, Ji-Hyung; Tak, Seong-Kun; Shim, Wangseob; Yim, Sung-Vin; Hong, Seung Jae; Lee, Kyung-Tae

    2010-10-01

    We describe a simple, rapid and sensitive high-performance liquid chromatography-electrospray ionization tandem mass spectrometric method that was developed for the simultaneous determination of carebastine and pseudoephedrine in human plasma using cisapride as an internal standard. Acquisition was performed in multiple-reaction monitoring mode by monitoring the transitions: m/z 500.43 > 167.09 for carebastine and m/z 166.04 > 147.88 for pseudoephedrine. The devised method involves a simple single-step liquid-liquid extraction with ethyl acetate. Chromatographic separation was performed on a C(18) reversed-phase chromatographic column at 0.2  mL/min by isocratic elution with 10  mM ammonium formate buffer-acetonitrile (30:70, v/v; adjusted to pH 3.3 with formic acid). The devised method was validated over 0.5-100  ng/mL of carebastine and 5-1000  ng/mL of pseudoephedrine with acceptable accuracy and precision, and was successfully applied to a bioequivalence study involving a single oral dose (10  mg of ebastine plus 120  mg of pseudoephedrine complex) to healthy Korean volunteers.

  15. Separation of small molecular peptides with the same amino acid composition but different sequences by high performance liquid chromatography-electrospray ionization-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Peptidomics has emerged as a new discipline in recent years. Mass spectrometry (MS) is the most universal and efficient tool for structure identification of proteins and peptides. However,there is a limitation for the identification of peptides with the same amino acid composition but different se-quences because these peptides have identical mass spectra of molecular ions. This paper presents a high performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS) method for the separation of small molecular peptides with the same amino acid composition but dif-ferent sequences. Two tripeptides of Gly-Ser-Phe and Gly-Phe-Ser were used as a model sample. The separation behavior has been investigated and the separation conditions have been optimized. Under the optimum conditions,good repeatability was achieved. The developed method could provide a helpful reference for the separation of other peptides with the same amino acid composition but different sequences in the study of proteomics and peptidomics.

  16. Simultaneous determination of quetiapine and three metabolites in human plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Kun-yanLI; Ze-nengCHENG; XinLI; Xue-lianBAI; Bi-kuiZHANG; FengWANG; Huan-deLI

    2004-01-01

    AIM:To develop a high performance liquid chromatography-electrospray mass spectrometry (HPLC-MS/ESI)method for simultaneous determination of quetiapine and its sulfoxide-, 7-hydroxy-, 7-hydroxy-N-dealkyl-metabolites in human plasma. METHODS: The HPLC separation of the compounds was performed on a Kromasil C18, (5μm, 4.6 mm×150 mm) column, using water (formic acid: 1.70 mmol/L, ammonium acetate: 5.8 mmol/L)-acetoni-trile (65:35) as mobile phase, with a flow-rate of 0.95 mL/min. The compounds were ionized in the electrospray ionization (ESI) ion source of the mass spectrometer and detected in the selected ion recording (SIR) mode. The samples were extracted using solid-phase extraction columns. RESULTS: The calibration curves were linear in theranges of 10-2000 μg/L for quetiapine, 1-200 μg/L for its metabolites, respectively. The average extraction recoveries for all the four samples were above 85 %. The methodology recoveries were much higher than 95 %. Theintra-day and inter-day RSD are less than 15 %. CONCLUSION: The method is accurate, sensitive, and simple for study of pharmacokinetics and metabolic mechanism of quetiapine in patients at therapeutic dose.

  17. 分散固相萃取-超高压液相色谱-串联质谱法测定黄瓜中的嗪胺灵%Determination of triforine in cucumber by dispersive solid phase extraction-ultra perssure liquid chromatography-electrospray ionization tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    陈武瑛; 张德咏; 李宗云; 何明远; 罗香文; 刘建宇; 刘绍文; 刘勇

    2013-01-01

    目的:建立黄瓜中嗪胺灵残留的液质串联快速分析检测方法。方法样品中的嗪胺灵经乙腈提取用 N-丙基乙二胺(PSA)和石墨化碳黑(GCB)净化,利用超高压液相色谱-串联质谱(UPLC-MS/MS)在多反应监测模式下进行检测。结果以碎片离子对432.8>212.9、432.8>82.9定性、离子对432.8>97.8进行外标法定量。仪器在0.01~1.00 mg/kg范围内,具有良好线性关系。在0.02~1.00 mg/kg添加水平范围内,嗪胺灵在黄瓜中的平均回收率为85.3%~92.2%,其相对标准偏差为2.8%~7.5%。该方法的检出限(LOD)为2.0μg/kg,定量限为(LOQ)为20μg/kg。结论本方法简便、快速、准确,能满足国内外法规的要求,可用于黄瓜样品中嗪胺灵的农药残留确证检测。%Objective A rapid method has been developed for the determination of germicide triforine re-sidues in cucumber. Methods The triforine from cucumber sample, which was extracted by acetonitrile and cleaned up by primary secondary amine (PSA) and graphitized carbon black (GCB), was determined by ultra perssure liquid chromatography-mass spectrometry under multiple reaction monitoring mode, then quantified by matrix-match standard solution. Results The qualitative results were obtained based on retention time, the precursor ion and three daughter ions, and the quantitation results were on the characteristic 432.8>212.9 ion, 432.8>82.9 ion and 432.8>97.8 ion. Average recoveries of triforine in cucumber samples were found in the range of 85.3%~92.2% at four spiking levels from 0.02 mg/kg to 1.0 mg/kg with relative standard deviations of 2.8%~7.5%. Limit of detections of triforine were 2.0 μg/kg, while limit of quantifications were 20 μg/kg, respectively. Conclusion The method is simple, rapid, and accurate, and it can meet the requirements of the domestic and international legislation. The method adapts to confirm residues of triforine pesticides in cu-cumber samples.

  18. Development of a method for comprehensive and quantitative analysis of plant hormones by highly sensitive nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Izumi, Yoshihiro; Okazawa, Atsushi; Bamba, Takeshi; Kobayashi, Akio [Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan); Fukusaki, Eiichiro, E-mail: fukusaki@bio.eng.osaka-u.ac.jp [Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan)

    2009-08-26

    In recent plant hormone research, there is an increased demand for a highly sensitive and comprehensive analytical approach to elucidate the hormonal signaling networks, functions, and dynamics. We have demonstrated the high sensitivity of a comprehensive and quantitative analytical method developed with nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry (LC-ESI-IT-MS/MS) under multiple-reaction monitoring (MRM) in plant hormone profiling. Unlabeled and deuterium-labeled isotopomers of four classes of plant hormones and their derivatives, auxins, cytokinins (CK), abscisic acid (ABA), and gibberellins (GA), were analyzed by this method. The optimized nanoflow-LC-ESI-IT-MS/MS method showed ca. 5-10-fold greater sensitivity than capillary-LC-ESI-IT-MS/MS, and the detection limits (S/N = 3) of several plant hormones were in the sub-fmol range. The results showed excellent linearity (R{sup 2} values of 0.9937-1.0000) and reproducibility of elution times (relative standard deviations, RSDs, <1.1%) and peak areas (RSDs, <10.7%) for all target compounds. Further, sample purification using Oasis HLB and Oasis MCX cartridges significantly decreased the ion-suppressing effects of biological matrix as compared to the purification using only Oasis HLB cartridge. The optimized nanoflow-LC-ESI-IT-MS/MS method was successfully used to analyze endogenous plant hormones in Arabidopsis and tobacco samples. The samples used in this analysis were extracted from only 17 tobacco dry seeds (1 mg DW), indicating that the efficiency of analysis of endogenous plant hormones strongly depends on the detection sensitivity of the method. Our analytical approach will be useful for in-depth studies on complex plant hormonal metabolism.

  19. Determination of the brominated flame retardant, hexabroomcyclodocane in sediments and biota by liquid chromatography-electrospray ionization mass spectrometry

    NARCIS (Netherlands)

    Morris, S.; Bersuder, P.; Allchin, C.R.; Zegers, B.; Boon, J.P.; Leonards, P.E.G.; Boer, de J.

    2006-01-01

    A method involving reversed-phase, liquid chromatography coupled to electrospray ionisation mass spectrometry (LC-ESI-MS) was developed for separation, detection and quantitation of the alpha-, beta- and gamma-diastereoisomers of hexabromocyclododecane (HBCD). To address the lack of environmental da

  20. Quantitative Analysis of Seven Triazine Herbicides by On-Line Micellar Electrokinetic Chromatography-Electrospray Ionization Mass Spectrometry

    International Nuclear Information System (INIS)

    This paper presents a successful demonstration of the on-line coupling of MEKC (micellar electrokinetic chromatography) to ESIMS (electrospray ionization mass spectrometry) for the quantitative analysis of seven s-triazine herbicides. The on-line MEKC-ESIMS was used to determine the structure of CE-separated peaks of seven triazine herbicides. The mixture of triazine herbicides was separated in a 20 mM sodium borate buffer (pH 8.5) containing 15 mM sodium dodecylsulfate (SDS) by using a bare fused-silica capillary. Electrospray ionization mass spectrometer was operated in the positive-ion mode when the mass spectra of seven triazine herbicides were observed from each peak, and the solution of water-methanol-formic acid (50/49/1 v/v/v) was used as a sheath liquid. The effects of SDS concentration, the run buffer pH, and the electric field on the separation of seven s-triazine herbicides were investigated. The MEKC-ESIMS detection showed 5 to 10 times higher sensitivity compared to the MEKC-UV detection. In addition, it did not need any pretreatment step

  1. Improvement of sugar analysis sensitivity using anion-exchange chromatography-electrospray ionization mass spectrometry with sheath liquid interface.

    Science.gov (United States)

    Xu, Xian-Bing; Liu, Ding-Bo; Guo, Xiao Ming; Yu, Shu-Juan; Yu, Pei

    2014-10-31

    A novel interface that enables high-performance anion-exchange chromatography (HPAEC) to be coupled with electrospray ionization (ESI) mass spectrometry (MS) is reported. A sheath liquid consisting of 50mM NH4Ac in isopropanol with 0.05% acetic acid, infused at a flow rate of 3μL/min at the tip of the electrospray probe, requires less ESI source cleaning and promotes efficient ionization of mono- and di-carbohydrates. The results suggest that use of a sheath liquid interface rather than a T-joint allows volatile ammonium salts to replace non-volatile metal salts as modifiers for improving sugar ESI signals. The efficient ionization of mono- and di-carbohydrates in the ESI source is affected by the sheath liquid properties such as buffer concentration and type of organic solvent. HPAEC-ESI-MS was used for the analysis of monocarbohydrates in pectins, particularly co-eluted sugars, and the performance was evaluated. Addition of a make-up solution through the sheath liquid interface proved to be an efficient tool for enhancing the intensities of sugars analyzed using HPAEC-ESI-MS.

  2. Comparison of direct infusion and on-line liquid chromatography/electrospray ionization mass spectrometry for the analysis of nucleic acids.

    Science.gov (United States)

    Huber, C G; Krajete, A

    2000-07-01

    The applicability of ion-pair reversed-phase high-performance liquid chromatography/electrospray ionization mass spectrometry (IP-RP-HPLC/ESI-MS) and direct infusion/ESI-MS to the characterization of nucleic acid mixtures was evaluated by the analysis of the reaction products obtained from solid-phase synthesis of a 39-mer oligonucleotide. IP-RP-HPLC/ESI-MS was performed using 200 microm i.d. capillary columns packed with octadecylated, micropellicular poly(styrene-divinylbenzene) particles and applying gradients of acetonitrile in 50 mM triethylammonium bicarbonate (TEAB). Three different solvent systems were utilized for direct infusion/ESI-MS with removal of metal cations by on-line cation exchange: (1) 10 mM triethylamine (TEA) in 50% aqueous acetonitrile, (2) 2.2 mM TEA, 400 mM hexafluoro-2-propanol (HFIP) in 20% aqueous methanol and (3) 50 mM TEAB in 10% aqueous acetonitrile. Owing to its separation capability, the highest selectivity and specificity were achieved with IP-RP-HPLC/ESI-MS, which, apart form the 39-mer target sequence, allowed the identification of two isobutyryl-protected target sequences and a 10-mer and 20-mer failure sequence. Direct infusion/ESI-MS with TEA-acetonitrile or TEA-HFIP-methanol as solvent revealed signals for the 39-mer in the m/z range 700-1600. The presence of derivatives containing one, two, three and four isobutyryl groups indicated that the hydrolysis of the protecting groups after solid-phase synthesis was not complete. Failure sequences could not be identified by direct infusion/ESI-MS under conditions favoring multiple charging of the analytes owing to the high chemical background and coincidental overlapping of m/z signals. However, efficient charge state reduction upon addition of carbonic acid to the electrosprayed solvent shifted the signals of the 39-mer and derivatives to m/z values >2400 and allowed the detection of seven different failure sequences, ranging from the 8-mer to the 23-mer, in the mixture.

  3. Detection of 20 carbamate pesticides in asparagus by ultra performance liquid chromatography-electrospray ionization-mass spectrometry-mass spectrometry%超高效液相色谱-电喷雾串联四极杆质谱法检测芦笋中20种氨基甲酸酯类农药残留

    Institute of Scientific and Technical Information of China (English)

    赵晓琳; 霍乃蕊; 花锦; 宋欢

    2015-01-01

    目的:建立芦笋及其罐头制品中20种氨基甲酸酯类农药残留的定性定量分析方法。方法采用改进的 QuEchERS 法提取和净化,利用超高效液相色谱-电喷雾串联四极杆质谱仪,在多反应监测正离子扫描模式下对样品进行添加回收率试验。结果分别对绿芦笋、白芦笋、绿芦笋罐头、白芦笋罐头4种空白基质添加0.005~0.050 mg/kg农药样品进行回收率试验,回收率为62.44%~85.99%,定量限均为0.005 mg/kg, RSD均小于9%。结论该方法简单快速,灵敏度高,能够同时满足芦笋及其罐头制品中20种氨基甲酸酯类农药残留的检测要求。%Objective To establish an ultra performance liquid chromatography-electrospray ionization-mass spectrometry-mass spectrometry method for detecting of 20 kinds of carbamate pesticides in asparagus and asparagus products. Methods Samples were extracted by modified QuEchERS method, and the mode of multi-reaction monitoring positive ion scanning was applied for analysis by ultra high performance liquid chromatography-electrospray tandem quadrupole mass spectrometer. Results The blank matrixes (green asparagus, white asparagus, canned white asparagus, canned white asparagus) were added 0.005~0.050 mg/kg carbamate pesticides separately and recovery tests were performed. Results demonstrated that the recovery rates were in the range of 62.44%~85.99% and the limits of quantification were 0.005 mg/kg for all the 20 carbamate pesticides tested with the relative standard deviations (RSDs) below 9%. Conclusion The method, not only simple and fast but also high sensitive, can satisfy the international detection requirement for 20 carbamate pesticides residue in asparagus product simultaneously.

  4. Characterization of heat-labile toxin-subunit B from Escherichia coli by liquid chromatography-electrospray ionization-mass spectrometry and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

    Science.gov (United States)

    Sospedra, I; De Simone, C; Soriano, J M; Mañes, J; Ferranti, P; Ritieni, A

    2012-11-01

    The possibilities of characterizing the heat-labile enterotoxin (LT) of enterotoxigenic Escherichia coli (ETEC) by liquid chromatography electrospray mass spectrometry (LC/ESI-MS) and matrix-assisted laser desorption with time-of-flight mass spectrometry (MALDI-TOF-MS) were investigated. The B subunit from recombinant E. coli (expression in Pichia pastoris) can be detected by LC/ESI-MS expressed in P. pastoris and the charge envelope signals can be observed; LC/ESI-MS and MALDI-TOF-MS analysis allowed the acquisition of labile toxin subunit B (LTB) molecular weight and preliminary structural characterization of LTB toxin. MALDI-TOF analysis after reduction and alkylation of the protein evidenced the presence of one disulfide bond in the structure of the protein. Confirmatory analysis was carried out by detection of most of the tryptic fragments of the B subunit by MALDI-TOF-MS, obtaining total coverage of the protein sequence. Possible biovariations in the toxin can mostly be determined by sequencing, where an increase of molecular mass in the N-terminal side of the protein was identified. This modification may be due to an O-GlcNAc-1-phosphorylation. PMID:22921353

  5. Liquid chromatography/electrospray ionization/isotopic dilution mass spectrometry analysis of n-(phosphonomethyl) glycine and mass spectrometry analysis of aminomethyl phosphonic acid in environmental water and vegetation matrixes.

    Science.gov (United States)

    Grey, L; Nguyen, B; Yang, P

    2001-01-01

    A liquid chromatography/electrospray/mass spectrometry (LC/ES/MS) method was developed for the analysis of glyphosate (n-phosphonomethyl glycine) and its metabolite, aminomethyl phosphonic acid (AMPA) using isotope-labelled glyphosate as a method surrogate. Optimized parameters were achieved to derivatize glyphosate and AMPA using 9-fluorenylmethyl chloroformate (FMOC-Cl) in borate buffer prior to a reversed-phase LC analysis. Method spike recovery data obtained using laboratory and real world sample matrixes indicated an excellent correlation between the recovery of the native and isotope-labelled glyphosate. Hence, the first performance-based, isotope dilution MS method with superior precision, accuracy, and data quality was developed for the analysis of glyphosate. There was, however, no observable correlation between the isotope-labelled glyphosate and AMPA. Thus, the use of this procedure for the accurate analysis of AMPA was not supported. Method detection limits established using standard U.S. Environmental Protection Agency protocol were 0.06 and 0.30 microg/L, respectively, for glyphosate and AMPA in water matrixes and 0.11 and 0.53 microg/g, respectively, in vegetation matrixes. Problems, solutions, and the method performance data related to the analysis of chlorine-treated drinking water samples are discussed. Applying this method to other environmental matrixes, e.g., soil, with minimum modifications is possible, assuring accurate, multimedia studies of glyphosate concentration in the environment and the delivery of useful multimedia information for regulatory applications.

  6. Ceramide lipids in alive and thermally stressed mussels: an investigation by hydrophilic interaction liquid chromatography-electrospray ionization Fourier transform mass spectrometry.

    Science.gov (United States)

    Facchini, Laura; Losito, Ilario; Cataldi, Tommaso R I; Palmisano, Francesco

    2016-09-01

    Hydrophilic interaction liquid chromatography coupled to electrospray ionization-Fourier transform mass spectrometry was employed to study ceramide lipids occurring in mussels of sp. Mytilus galloprovincialis. Lipid extracts from alive mussels and mussels deliberately subjected to specific thermal treatments were analyzed. In particular, single and tandem MS measurements were performed on a hybrid quadrupole-Orbitrap mass spectrometer and then complemented by MS(n) analyses (n = 2, 3) achieved by a linear ion trap mass spectrometer. This approach enabled the characterization of 66 ceramide lipids, encompassing ceramide phosphoethanolamines (CPE), ceramide aminoethylphosphonates (CAEP) and N-monomethylated CAEP. The sphingoid and acyl chains of each ceramide lipid could be distinctly recognized in terms of numbers of carbon atoms and C=C bonds, and indications on the possible location of the latter on the sphingoid chain could be often inferred from fragmentation patterns. The occurrence of several species hydroxylated on the α carbon of the acyl chain was also discovered. On the other hand, the sphingoid chain of ceramide lipids was never found to be involved in oxidation processes, unless forced exposure of the mussel lipid extracts to atmospheric oxygen was performed. CPE(d19:3/16:0) and its hydroxylated form, CPE(d19:3/2-OH-16:0), were found to be the prevailing species among CPE, whereas CAEP(d18:2/16:0), CAEP(d19:3/16:0) and CAEP(d19:3/2-OH-16:0) were the most abundant CAEP. Finally, ceramide lipids showed a remarkably higher stability, compared with glycerophospholipids, in mussels subjected to different thermal treatments. This finding opens interesting perspectives on the role of ceramide-based lipids in the adaptation of aquatic organisms to thermal stresses. Copyright © 2016 John Wiley & Sons, Ltd.

  7. A Nanoparticle-based Solid Phase Extraction Method for Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometric Analysis

    OpenAIRE

    Song, Yaru; Zhao, Shulin; Tchounwou, Paul; Liu, Yi-Ming

    2007-01-01

    A solid-phase extraction (SPE) procedure with the use of superparamagnetic Fe3O4 nanoparticles as extracting agent was developed for HPLC-ESI-MS/MS analysis. Four most heavily used triazine pesticides (herbicides) were taken as the test compounds. The NPs showed an excellent capability to retain the compounds tested, and a quantitative extraction was achieved within 10 min under the testing conditions, i.e. 100 μL NP solution was added to 400 mL sample in a beaker with stirring. After extract...

  8. Screening for gestagens in kidney fat using accelerated solvent extraction and liquid chromatography electrospray tandem mass spectrometry

    NARCIS (Netherlands)

    Hooijerink, H.; Bennekom, van E.O.; Nielen, M.W.F.

    2003-01-01

    A screening method has been developed for the determination of various anabolic steroids in kidney fat. Fat samples are extracted and steroids are trapped "on-line" during accelerated solvent extraction (ASE). Following this initial extraction samples are further purified with C18 solid-phase extrac

  9. Multi residue screening of intact testosterone esters and boldenone undecylenate in bovine hair using liquid chromatography electrospray tandem mass spectrometry

    NARCIS (Netherlands)

    Nielen, M.W.F.; Lasaroms, J.J.P.; Mulder, P.P.J.; Hende, van J.; Rhijn, van J.A.; Groot, M.J.

    2006-01-01

    The abuse of esters of natural androgenic steroids in cattle fattening and sports is hard to control via routine urine testing. The esters are rapidly hydrolysed in vivo into substances which are also endogenously present in urine. In veterinary control strange findings of 17ß-testosterone and 17¿-t

  10. Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometric Analysis of 2-Alkylcyclobutanones in Irradiated Chicken by Precolumn Derivatization with Hydroxylamine

    NARCIS (Netherlands)

    Ye, Yuran; Liu, Hanxia; Horvatovich, Peter; Chan, Wan

    2013-01-01

    Food irradiation is a common preservation method that is used in many countries. The ability to identify irradiated food is important for assuring compliance with regulatory policies, such as food labeling requirements, and for informed consumer choice. There is thus a significant demand for analyti

  11. Determination of sodium tanshinone IIA sulfonate in plasma by liquid chromatography-electrospray ionisation-tandem mass spectrometry.

    Science.gov (United States)

    Hao, Haiping; Wang, Guangji; Cui, Nan; Li, Jing; Ding, Zuoqi

    2007-11-01

    Sodium tanshinone IIA sulfonate (STS) is a water-soluble derivative of tanshinone IIa, an important lipophilic component contained in Salvia miltiorrhizae. A simple, sensitive and robust quantification method for STS based on LC-ESI-MS/MS was developed and validated, and has been successfully applied to the pharmacokinetic study. Liquid-liquid extraction was used for extracting STS from biological samples, with a satisfactory recovery exceeding 75% at all test concentrations. Isocratic mobile phase consisted of 75% acetonitrile and 25% water containing 0.005% ammonia acetate (pH 3). Good retention and baseline separation for STS and the selected internal standard, diclofenac sodium, were obtained on a Shim-pack VP-ODS analytical column under this condition. The method was linear in the concentration range of 1-500 ng/mL. The intra- and inter-day precisions (RSD%) were within 9.0%. The deviation of the assay accuracies was within +/-10.0%. STS was proved to be stable during all sample storing, preparation and analytic procedures. With a lower limit of quantitation at 1 ng/mL, this method has been proved to be sensitive enough for the pharmacokinetic study of STS. The plasma profile of STS followed a single intravenous dosing was well fitted to a three compartmental model. PMID:17630641

  12. Analysis of iridoid glucosides in Hedyotis diffusa by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Li, Cunman; Xue, Xingya; Zhou, Dayong; Zhang, Feifang; Xu, Qing; Ren, Lingling; Liang, Xinmiao

    2008-09-10

    An HPLC-DAD-ESI-MS/MS method was developed for analysis of iridoid glucosides (IGs) from Hedyotis diffusa Willd. The optimized separation condition was achieved with the Complex Sample Analysis Software System (CSASS) software, under which the whole analytes were achieved complete resolution especially for some isomeric IGs. Based on the UV and fragmentations, eleven IGs were detected. According to the fragmentation patterns of the three standard IGs, especially those of the isomeric standards, seven IGs including three pairs of isomers were unambiguous/tentatively identified. For the isomeric IGs with methyl ester or carboxyl group at C-4, the extents of the losses of CH3OH and/or H2O from their molecular and/or the aglycone adducts are useful for the differentiation of the stereoisomers in positive ion (PI) mode, which depends on the stereochemistry of the hydroxyl group on the cyclopentanoid unit. PMID:18579330

  13. Characterization of phosphoantigens by high-performance anion-exchange chromatography-electrospray ionization ion trap mass spectrometry and nanoelectrospray ionization ion trap mass spectrometry.

    Science.gov (United States)

    Pont, F; Luciani, B; Belmant, C; Fournié, J J

    2001-08-01

    New phosphorylated microbial metabolites referred to as phosphoantigens activate immune responses in humans. Although these molecules have leading applications in medical research, no direct method allows their rapid and unambiguous structural identification. Here, we interfaced online HPAEC (high performance anion-exchange chromatography) with ESI-ITMS (electrospray ionization ion trap mass spectrometry) to identify such pyrophosphorylated molecules. A self-regenerating anion suppressor located upstream of electrospray ionization enabled the simultaneous detection of pyrophosphoester by conductimetry, UV and MS. By HPAEC-ITMS and HPAEC-ITMS2, a single run permitted characterization of reference phosphoantigens and of related structures. Although all compounds were resolved by HPAEC, MS enabled their detection and identification by [M-H]- and fragment ions. Isobaric phosphoantigen analogues were also separated by HPAEC and distinguished by MS2. The relevance of this device was demonstrated for phosphoantigens analysis in human urine and plasma. Furthermore, identification of natural phosphoantigens by automatically generated 2D mass spectra from nano-ESI-ITMS is presented. This last technique permits the simultaneous performance of molecular screening of natural phosphoantigen extracts and their identification.

  14. Determination of energy metabolites in cancer cells by porous graphitic carbon liquid chromatography electrospray ionization mass spectrometry for the assessment of energy metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Szoboszlai, Norbert, E-mail: szobosz@chem.elte.hu [Laboratory of Environmental Chemistry and Bioanalytics, Department of Analytical Chemistry, Institute of Chemistry, Eötvös Loránd University, Pázmány Péter stny 1/A, H-1117 Budapest (Hungary); Guo, Xinghua [Institute of Analytical Chemistry and Food Chemistry, Graz University of Technology, Stremayrgasse 9, 8010 Graz (Austria); Ozohanics, Olivér [Research Centre for Natural Sciences of the Hungarian Academy of Sciences, Pusztaszeri u. 59-67, H-1025 Budapest (Hungary); Oláh, Júlia [1st Institute of Pathology and Experimental Cancer Research, Semmelweis University, H-1085 Budapest (Hungary); Gömöry, Ágnes [Research Centre for Natural Sciences of the Hungarian Academy of Sciences, Pusztaszeri u. 59-67, H-1025 Budapest (Hungary); Mihucz, Victor G. [Laboratory of Environmental Chemistry and Bioanalytics, Department of Analytical Chemistry, Institute of Chemistry, Eötvös Loránd University, Pázmány Péter stny 1/A, H-1117 Budapest (Hungary); Jeney, András [1st Institute of Pathology and Experimental Cancer Research, Semmelweis University, H-1085 Budapest (Hungary); Vékey, Károly [Research Centre for Natural Sciences of the Hungarian Academy of Sciences, Pusztaszeri u. 59-67, H-1025 Budapest (Hungary)

    2014-03-01

    Graphical abstract: - Highlights: • All types of sugar metabolites can be investigated in one run on graphitic stationary phase. • Method development for acidic metabolites of energy metabolism using a single LC–MS run. • Study of 15 acidic energy metabolites on a PGC column using common eluents. • Lactate, acidic amino acid, organic acid and sugar phosphate determination in a single run. • Metabolism of U-{sup 13}C glucose and 1-{sup 13}C acetate in ZR-75-1 cells studied. - Abstract: A high performance liquid chromatography (HPLC) tandem mass spectrometric (MS/MS) method has been developed for the simultaneous determination of fifteen glucose, or acetate derived metabolites isolated from tumor cells. Glycolytic and tricarboxylic acid (TCA) cycle metabolites as well as acidic amino acids were separated on a HPLC porous graphitic carbon (PGC) column and simultaneously determined by means of triple quadrupole MS/MS using multiple reaction monitoring (MRM). Target compounds were eluted within 10 min with 8% v/v formic acid as an electronic modifier added to a 4:1 v/v methanol water mobile phase. The calibration is linear in the 1–100 μM concentration range for each analyte. The limit of detection ranges between 0.39 and 2.78 μM for the analytes concerned. To test the PGC–HPLC–MS/MS method in metabolomic studies, ZR-75.1 human mammary adenocarcinoma cells were labeled with U-{sup 13}C glucose or 1-{sup 13}C acetate. Applying the MRM mode, the incorporation of {sup 13}C into metabolites, isolated from the tumor cells, and derived from glucose or acetate, could be properly identified.

  15. Comparison of microbial communities in Lake Tahoe surface sample with Tonga Trench water column samples using High Pressure Liquid Chromatography - Electrospray Ionization - Mass Spectroscopy (HPLC - ESI - MS) and Global Natural Products Social Molecular Network (GNPS)

    Science.gov (United States)

    Belmonte, M. A.

    2015-12-01

    Intact polar lipids (IPLs) are lipids composed of a head group, a glycerol, and a fatty acid chain that make up the lipid bilayer of cell membranes in living cells; and the varying head groups can be indicative of the type of microbes present in the environment (Van Mooy 2010). So by distinguishing and identifying the IPL distribution in an environment one can make inferences about the microbial communities in the said environment. In this study, we used High Pressure Liquid Chromatography-Electrospray Ionization- Mass Spectroscopy (HPLC-ESI-MS) and Global Natural Products Social Molecular Networking (GNPS) to compare the IPL distributions of two oligotrophic environments: surface waters of Lake Tahoe in the Sierra Nevada Mountains, and the water column of the Tonga Trench in the South Pacific. We hypothesized that the similar nutrient dynamics of the two oligotrophic environments would result in similar eukaryotic and prokaryotic communities, which would be reflected in the IPL composition of suspended particulate organic matter (POM). For simplicity we focused on the classes of IPLs most commonly observed in the marine environment: phosphotidylglycerol (PG), phosphotidylethanolamine (PE), diacylglyceryl-trimethyl-homoserine (DGTS), diacylglyceryl-hydroxymethyl-trimethylalanine (DGTA), sulfoquinovosyldiacylglycerol (SQDG), monoglycosyldiacylglycerol (MGDG) and diglycosyldiacylglycerol (DGDG). Our results showed that all of the marine IPLs of interest were present in Lake Tahoe which confirms that there are many of the same microbial communities in the fresh waters of Lake Tahoe and the salt waters Tonga Trench.

  16. Optimization of the extraction of anthocyanins from the fruit skin of Rhodomyrtus tomentosa (Ait.) Hassk and identification of anthocyanins in the extract using High-Performance Liquid Chromatography-Electrospray Ionization-Mass Spectrometry (HPLC-ESI-MS).

    Science.gov (United States)

    Liu, Guo-Ling; Guo, Hong-Hui; Sun, Yuan-Ming

    2012-01-01

    Anthocyanins are naturally occurring polyphenols that impart bright color to fruits, vegetables and plants. In this study, the extraction of anthocyanins from freeze-dried fruit skin of downy rose-myrtle (Rhodomyrtus tomentosa (Ait.) Hassk var. Gangren) was optimized using response surface methodology (RSM). Using 60% ethanol containing 0.1% (v/v) hydrochloric acid as extraction solvent, the optimal conditions for maximum yields of anthocyanin (4.358 ± 0.045 mg/g) were 15.7:1 (v/w) liquid to solid ratio, 64.38 °C with a 116.88 min extraction time. The results showed good fits with the proposed model for the anthocyanin extraction (R(2) = 0.9944). Furthermore, the results of high-performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS) analysis of the anthocyanins extracted from the fruit skin of downy rose-myrtle revealed the presence of five anthocyanin components, which were tentatively identified as delphinidin-3-glucoside, cyanidin-3-glucoside, peonidin-3-glucoside, petunidin-3-glucoside and malvidin-3-glucoside.

  17. Application of a liquid chromatography-electrospray mass spectrometry (LC/MS) method to the biodistribution and excretion studies of novel 5'-chloro-2, 3-didehydroindolo (2', 3': 2, 3) betulinic acid (DRF-4012) in tumour-bearing mice.

    Science.gov (United States)

    Mishra, Gautam; Singh, Manoj Kumar; Awasthi, Anshumali; Singh, Anu T; Jaggi, Manu; Ahmad, Farhan J

    2013-06-01

    Novel betulinic acid derivative 5'-chloro-2, 3-didehydroindolo [2', 3': 2, 3] betulinic acid (DRF-4012) is a new effective lupane type triterpenes with greater anticancer activity and efficacy than betulinic acid and currently under advanced preclinical investigation phase. In this study, a sensitive and rapid liquid chromatography-electrospray mass spectrometric (LC/MS) method has been developed for the determination of DRF-4012 in tumour-bearing mice plasma, urine, feces and tissues (liver, brain, lungs, heart, spleen, stomach, thigh muscle, kidneys, urinary bladder, small intestine and tumour). Biodistribution and excretion studies were performed for DRF-4012 nanoparticle (30 mg/kg body weight) after intravenous (i.v.) injection in tumour-bearing mice. DRF-4012 rapidly distributed throughout the body. After 0.5 h, tumour showed the second highest concentration, which was nearly half of the liver. After 4 and 24 h, the highest concentration of DRF-4012 was found in tumour indicating its retention in tumour site for a longer time. Excretion studies revealed that very low amount of unchanged DRF-4012 was observed in urine and primarily excreted through fecal route. This study may be useful to explain the manner in which DRF-4012 can inhibit tumour growth without apparent toxicity and preclinical/clinical evaluation of this potential antitumour agent.

  18. Characterization of isoquinoline alkaloids, diterpenoids and steroids in the Chinese herb Jin-Guo-Lan (Tinospora sagittata and Tinospora capillipes) by high-performance liquid chromatography/electrospray ionization with multistage mass spectrometry.

    Science.gov (United States)

    Zhang, Yufeng; Shi, Qirong; Shi, Peiying; Zhang, Weidong; Cheng, Yiyu

    2006-01-01

    This study sought to determine the primary components (isoquinoline alkaloids, diterpenoids and steroids) in crude extracts of the Chinese herb Jin-Guo-Lan, prepared from the roots of Tinospora sagittata and T. capillipes, by liquid chromatography/electrospray ionization multistage mass spectrometry coupled with diode-array detection (LC-DAD/ESI-MS(n)). After separation on a reversed-phase C(18) column using gradient elution, positive and negative ESI-MS experiments were performed. In positive ion mode, the three types of compounds showed very different characteristic ions: strong [M](+) or [M+H](+) ions were observed for isoquinoline alkaloids; [M+NH(4)](+) and/or [M+H-CO(2)](+) for diterpenoids; [M+H-nH(2)O](+) (n=1-3) for steroids. These adduct ions and/or fragments were used to deduce the mass and categories of known and unknown components in crude extracts, and their structures were further confirmed by ESI-MS(n) in positive ion mode. Moreover, UV absorption peaks obtained from DAD provided useful functional group information to aid the MS(n)-based identification. As a result, 11 compounds were unambiguously identified by comparing with standard compounds and 13 compounds were tentatively identified or deduced according to their MS(n) data. Two of these compounds (13-hydroxycolumbamine and 13-hydroxyjatrorrhizine) were found to be new compounds and another one (13-hydroxypalmatine) was detected for the first time as a natural product. In addition, a [M-*CH(3)-H(2)O](*+) ion in MS(2) of [M](+) after in-source collision-induced dissociation was used to differentiate positional isomers of protoberberine alkaloids, columbamine and jatrorrhizine. Although the roots of T. sagittata and T. capillipes contain almost identical compounds, the content of the compounds in them is dramatically different, suggesting the necessity for further comparison of the bioactivities of the two species. PMID:16817243

  19. Regiospecific analysis of neutral ether lipids by liquid chromatography/electrospray ionization/single quadrupole mass spectrometry: validation with synthetic compounds

    DEFF Research Database (Denmark)

    Hartvigsen, Karsten; Ravandi, A.; Bukhave, Klaus;

    2001-01-01

    characterized by chromatographic retention times, full mass spectra, and fragmentation patterns as an aid to clarify the regiospecificity of ether lipids from natural sources. The results clearly show that single quadrupole mass spectroscopic analysis may elucidate the regiospecific structure of neutral ether......A reversed-phase high-performance liquid chromatography (HPLC) method with on-line electrospray ionization/collision-induced dissociation/mass spectrometry (ESI/CID/MS) is presented for the regiospecific analysis of synthetic reference compounds of neutral ether lipids. The reference compounds were...... + H - H2O](+), whereas the reverse situation characterized the sn-3 species. Furthermore, corresponding sn-2 and sn-3 species were separated by the chromatographic system. However, loss of water was promoted as fatty acid unsaturation was raised, which may complicate interpretation of the mass spectra...

  20. Classification of cultivation locations of panax quinquefolius L samples using high performance liquid chromatography-electrospray ionization mass spectrometry and chemometric analysis

    Science.gov (United States)

    Panax quinquefolius L (P. quinquefolius L) samples grown in the United States and China were analyzed with high performance liquid chromatography-mass spectrometry (HPLC—MS). Prior to classification, the two-way datasets were subjected to pretreatment including baseline correction and retention ti...

  1. Identification of intact high molecular weight glutenin subunits from the wheat proteome using combined liquid chromatography-electrospray ionization mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Bert Lagrain

    Full Text Available The present paper describes a method for the identification of intact high molecular weight glutenin subunits (HMW-GS, the quality determining proteins from the wheat storage proteome. The method includes isolation of HMW-GS from wheat flour, further separation of HMW-GS by reversed-phase high-performance liquid chromatography (RP-HPLC, and their subsequent molecular identification with electrospray ionization mass spectrometry using a quadrupole-time-of-flight mass analyzer. For HMW-GS isolation, wheat proteins were reduced and extracted from flour with 50% 1-propanol containing 1% dithiothreitol. HMW-GS were then selectively precipitated from the protein mixture by adjusting the 1-propanol concentration to 60%. The composition of the precipitated proteins was first evaluated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis with Coomassie staining and RP-HPLC with ultraviolet detection. Besides HMW-GS (≥65%, the isolated proteins mainly contained ω5-gliadins. Secondly, the isolated protein fraction was analyzed by liquid chromatography-mass spectrometry. Optimal chromatographic separation of HMW-GS from the other proteins in the isolated fraction was obtained when the mobile phase contained 0.1% trifluoroacetic acid as ion-pairing agent. Individual HMW-GS were then identified by determining their molecular masses from the high-resolution mass spectra and comparing these with theoretical masses calculated from amino acid sequences. Using formic acid instead of trifluoroacetic acid in the mobile phase increased protein peak intensities in the base peak mass chromatogram. This allowed the detection of even traces of other wheat proteins than HMW-GS in the isolated fraction, but the chromatographic separation was inferior with a major overlap between the elution ranges of HMW-GS and ω-gliadins. Overall, the described method allows a rapid assessment of wheat quality through the direct determination of the HMW-GS composition and

  2. Screening and quantitation of multiclass drugs of abuse and pharmaceuticals in hair by fast liquid chromatography electrospray time-of-flight mass spectrometry.

    Science.gov (United States)

    Domínguez-Romero, Juan C; García-Reyes, Juan F; Molina-Díaz, Antonio

    2011-07-15

    In this work, an automated screening method for the simultaneous identification and quantitation of 30 representative multiclass drugs (including opiates, cocaine and its main metabolite, cannabinoids, amphetamines and other stimulants in hair samples) has been developed using fast liquid-chromatography time-of-flight mass spectrometry (LC-TOFMS). The identification and quantitation of the drugs were carried out by liquid chromatography using a C(18) column (4.6×50 mm) with 1.8 μm particle size. Accurate mass measurements of ions of interest (typically [M+H](+)) by electrospray time-of-flight mass spectrometry in the positive ionization mode were used for unambiguous confirmation of the targeted species. Three sample preparation methodologies were evaluated: (a) direct methanolic extraction by sonication, (b) acidic extraction, and (c) alkaline digestion. Direct methanolic extraction showed better recoveries and cleaner extracts. The limits of detection obtained in hair matrix were as low as 5 pg mg(-1) for cocaine and cannabidiol, ranging from 5 to 75 pg mg(-1) for the studied species while the LOQ ranged from 15 to 250 pg mg(-1). The method has been applied to six hair samples from drug consumer volunteers, where the presence of at least one drug was confirmed by accurate mass measurements within 2 ppm (mass error) in most cases. The present study demonstrates the usefulness of LC-TOFMS for both screening and quantitation purposes in drug testing in hair. In addition, the possibility of non-target or a posteriori data analysis of samples or the extension of the procedure for testing for additional compounds offers interesting features for forensic analysis.

  3. Liquid chromatography-electrospray ionization mass spectrometry of the diarrhetic shellfish-poisoning toxins okadaic acid, dinophysistoxin-1 and pectenotoxin-6 in bivalves.

    Science.gov (United States)

    Suzuki, T; Yasumoto, T

    2000-04-01

    Determination of diarrhetic shellfish-poisoning (DSP) toxins, okadaic acid (OA), dinophysistoxin-1 (DTX1) and pectenotoxin-6 (PTX6) was carried out by liquid chromatography (LC) followed by on-line atmospheric pressure electrospray ionization-mass spectrometric (ESI-MS) detection with a heated capillary interface. Mass spectra of authentic OA, DTXI and PTX6 standards exhibited abundant [M-H] at m/z 803, 817 and 887, respectively. Linearity of peak area obtained by selected-ion monitoring (SIM) for [M-H]- of each toxin was confirmed over a wide range of concentrations from 10 pg to 30 ng. LC-ESI-MS analysis of OA, DTX1 and PTX6 in scallops and mussels, collected at the same site (Mutsu Bay, Japan), was carried out. Scallops and mussels collected at the same site showed different toxin profiles. Although PTX6 was detected from scallops, it was not detected from mussels. PMID:10817358

  4. Ion chromatography electrospray ionization mass spectrometry method development and investigation of lithium hexafluorophosphate-based organic electrolytes and their thermal decomposition products.

    Science.gov (United States)

    Kraft, Vadim; Grützke, Martin; Weber, Waldemar; Winter, Martin; Nowak, Sascha

    2014-08-01

    A method based on the coupling of ion chromatography (IC) and electrospray ionization mass spectrometry (ESI-MS) for the separation and determination of thermal decomposition products of LiPF6-based organic electrolytes is presented. The utilized electrolytes, LP30 and LP50, are commercially available and consist of 1mol/l LiPF6 dissolved in ethylene carbonate/dimethyl carbonate and ethylene carbonate/ethyl methyl carbonate, respectively. For the separation method development three ion chromatographic columns with different capacity and stationary phase were used and compared. Besides the known hydrolysis products of lithium hexafluorophosphate, several new organophosphates were separated and identified with the developed IC-ESI-MS method during aging investigations of the electrolytes. The chemical structures were elucidated with IC-ESI-MS/MS. PMID:24939088

  5. Antioxidant activity and identification of bioactive compounds from leaves of Anthocephalus cadamba by ultra-performance liquid chromatography/electrospray ionization quadrupole time of flight mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Madhu Chandel; Upendra Sharma; Neeraj Kumar; Bikram Singh; Satwinderjeet Kaur

    2012-01-01

    Objective: To evaluate the antioxidant potential of different extract/fractions of Anthocephalus cadamba (A. cadamba) (Roxb.) Miq. (Rubiaceae) and study the tentative identification of their active constituents. Methods: The extract/fractions were screened for antioxidant activity using various in vitro assays viz. DPPH assay, ABTS assay, superoxide anion radical scavenging assay, reducing power assay and plasmid DNA nicking assay. Total phenolic content of extract/fractions was determined by colorimetric method. An ultra-performance LC-electrospray-quadrupole-time of flight mass spectrometry method was used to analyse the active constituents of extract/fractions of A. cadamba. Results: The ethyl acetate fraction was found to be most active fraction in all the assays as compared to other extract/fractions. The IC50 value of ethyl acetate fraction (ETAC fraction) was 21.24 μg/mL, 1.12 μg/mL, 9.68 μg/mL and 57.81 μg/mL in DPPH assay, ABTS assay, reducing power assay and superoxide scavenging assay respectively. All the extract/fractions also showed the potential to protect the plasmid DNA (pBR322) against the attack of hydroxyl radicals generated by Fenton’s reagent. The bioactive compounds were identified by UPLC-ESI-QTOF-MS, by comparing the mass and λmax with literature values. Conclusions: The potential of the extract/fractions to scavenge different free radicals in different systems indicated that they may be useful therapeutic agents for treating radical-related pathologic damage.

  6. Metabolomics Analysis of Health Functions of Physalis Pubescens L. using by Ultra-performance Liquid Chromatography/Electrospray Ionization Quadruple Time-of-Flight Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    Hang Chu; Hui Sun; Guang-Li Yan; Ai-Hua Zhang; Chang Liu; Hui Dong; Xiang-Cai Meng; Xi-Jun Wang

    2015-01-01

    Herbal medicines may benefit from metabolomics studies, and applying metabolomics may provide answers about which herbal interventions may be effective for individuals, which metabolic processes are triggered, and the subsequent chemical pathways of activity. Physalis pubescens L (PPL) is an herbal fruit for one year living plant and has been developed into healthy function’s food. However, the mechanisms of health functions are still unclear. To comprehensively and holistically assess its anti-fatigue and antioxidant effects, a novel integrative metabolomics approach was applied. In this study, we present metabolomics analysis applying ultra performance liquid chromatography coupled to quadrupole with time-of-flight mass spectrometry (UPLC-Q/TOF-MS) to determine metabolite alterations after oral administration PPL to rats. Fifteen metabolites in urine were identified as potential biomarkers. Pattern analysis of the UPLC-Q/TOF-MS data disclosed that PPL could relieve fatigue rats by ameliorating the disturbance in amino acids metabolism and energy metabolism, alleviating the oxidative stress from reactive oxygen species and the inflammatory damage, and recovering the destructed regulation. Based on these results, we demonstrated that PPL is a promising source of natural anti-fatigue and antioxidants material for use in functional foods and medicines.

  7. Metabolomics Analysis of Health Functions of Physalis Pubescens L. using by Ultra-performance Liquid Chromatography/Electrospray Ionization Quadruple Time-of-Flight Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Hang Chu

    2015-07-01

    Full Text Available Herbal medicines may benefit from metabolomics studies, and applying metabolomics may provide answers about which herbal interventions may be effective for individuals, which metabolic processes are triggered, and the subsequent chemical pathways of activity. Physalis pubescens L (PPL is an herbal fruit for one year living plant and has been developed into healthy function's food. However, the mechanisms of health functions are still unclear. To comprehensively and holistically assess its anti-fatigue and antioxidant effects, a novel integrative metabolomics approach was applied. In this study, we present metabolomics analysis applying ultra performance liquid chromatography coupled to quadrupole with time-of-flight mass spectrometry (UPLC-Q/TOF-MS to determine metabolite alterations after oral administration PPL to rats. Fifteen metabolites in urine were identified as potential biomarkers. Pattern analysis of the UPLC-Q/TOF-MS data disclosed that PPL could relieve fatigue rats by ameliorating the disturbance in amino acids metabolism and energy metabolism, alleviating the oxidative stress from reactive oxygen species and the inflammatory damage, and recovering the destructed regulation. Based on these results, we demonstrated that PPL is a promising source of natural anti-fatigue and antioxidants material for use in functional foods and medicines.

  8. Reduction of matrix effects in liquid chromatography-electrospray ionization-mass spectrometry by dilution of the sample extracts: how much dilution is needed?

    Science.gov (United States)

    Stahnke, Helen; Kittlaus, Stefan; Kempe, Günther; Alder, Lutz

    2012-02-01

    In this study, the relationship between matrix concentration and suppression of electrospray ionization (matrix effects) was investigated. Ion suppression of pesticides present in QuEChERS extracts was used as an example. Residue-free extracts of four different commodities, avocado, black tea, orange, and rocket (arugula), were fortified with 39 pesticides each. For many of the resulting 156 pesticide/matrix combinations, considerable matrix effects were observed if the coextracted matrix of 8 mg of equivalent sample (in the case of tea: 1.6 mg) was injected with the undiluted extracts. The reduction of these matrix effects was measured at 10 levels of dilution up to 1000-fold. The results obtained indicate a linear correlation between matrix effects and the logarithm of matrix concentration (or dilution factor) until the zero-effect level of further dilution was reached. Using the logarithmic equations, it could be shown that a dilution of extracts by a factor of 25-40 reduces ion suppression to less than 20% if the initial suppression is ≤80%. For stronger matrix effects or complete elimination of suppression, higher dilution factors were needed. The observed correlation was independent from the two instrument platforms used, but the degree of matrix effects differed slightly between the two mass spectrometers in this study.

  9. Liquid chromatography-electrospray linear ion trap mass spectrometry analysis of targeted neuropeptides in Tac1(-/-) mouse spinal cords reveals significant lower concentration of opioid peptides.

    Science.gov (United States)

    Saidi, Mouna; Beaudry, Francis

    2015-08-01

    Tachykinin and opioid peptides play a central role in pain transmission, modulation and inhibition. The treatment of pain is very important in medicine and many studies using NK1 receptor antagonists failed to show significant analgesic effects in humans. Recent investigations suggest that both pronociceptive tachykinins and the analgesic opioid systems are important for normal pain sensation. The analysis of opioid peptides in Tac1(-/-) spinal cord tissues offers a great opportunity to verify the influence of the tachykinin system on specific opioid peptides. The objectives of this study were to develop an HPLC-MS/MRM assay to quantify targeted peptides in spinal cord tissues. Secondly, we wanted to verify if the Tac1(-/-) mouse endogenous opioid system is hampered and therefore affects significantly the pain modulatory pathways. Targeted neuropeptides were analyzed by high performance liquid chromatography linear ion trap mass spectrometry. Our results reveal that EM-2, Leu-Enk and Dyn A were down-regulated in Tac1(-/-) spinal cord tissues. Interestingly, Dyn A was almost 3 fold down-regulated (p<0.0001). No significant concentration differences were observed in mouse Tac1(-/-) spinal cords for Met-Enk and CGRP. The analysis of Tac1(-/-) mouse spinal cords revealed noteworthy decreases of EM-2, Leu-Enk and Dyn A concentrations which strongly suggest a significant impact on the endogenous pain-relieving mechanisms. These observations may have insightful impact on future analgesic drug developments and therapeutic strategies.

  10. Determination of pharmaceutical compounds in surface- and ground-water samples by solid-phase extraction and high-performance liquid chromatography-electrospray ionization mass spectrometry

    Science.gov (United States)

    Cahill, J.D.; Furlong, E.T.; Burkhardt, M.R.; Kolpin, D.; Anderson, L.G.

    2004-01-01

    Commonly used prescription and over-the-counter pharmaceuticals are possibly present in surface- and ground-water samples at ambient concentrations less than 1 μg/L. In this report, the performance characteristics of a combined solid-phase extraction isolation and high-performance liquid chromatography–electrospray ionization mass spectrometry (HPLC–ESI-MS) analytical procedure for routine determination of the presence and concentration of human-health pharmaceuticals are described. This method was developed and used in a recent national reconnaissance of pharmaceuticals in USA surface waters. The selection of pharmaceuticals evaluated for this method was based on usage estimates, resulting in a method that contains compounds from diverse chemical classes, which presents challenges and compromises when applied as a single routine analysis. The method performed well for the majority of the 22 pharmaceuticals evaluated, with recoveries greater than 60% for 12 pharmaceuticals. The recoveries of angiotensin-converting enzyme inhibitors, a histamine (H2) receptor antagonist, and antihypoglycemic compound classes were less than 50%, but were retained in the method to provide information describing the potential presence of these compounds in environmental samples and to indicate evidence of possible matrix enhancing effects. Long-term recoveries, evaluated from reagent-water fortifications processed over 2 years, were similar to initial method performance. Method detection limits averaged 0.022 μg/L, sufficient for expected ambient concentrations. Compound-dependent matrix effects on HPLC/ESI-MS analysis, including enhancement and suppression of ionization, were observed as a 20–30% increase in measured concentrations for three compounds and greater than 50% increase for two compounds. Changing internal standard and more frequent ESI source maintenance minimized matrix effects. Application of the method in the national survey demonstrates that several

  11. Analysis of anthocyanins in commercial fruit juices by using nano-liquid chromatography-electrospray-mass spectrometry and high-performance liquid chromatography with UV-vis detector.

    Science.gov (United States)

    Fanali, Chiara; Dugo, Laura; D'Orazio, Giovanni; Lirangi, Melania; Dachà, Marina; Dugo, Paola; Mondello, Luigi

    2011-01-01

    Nano-LC and conventional HPLC techniques were applied for the analysis of anthocyanins present in commercial fruit juices using a capillary column of 100 μm id and a 2.1 mm id narrow-bore C(18) column. Analytes were detected by UV-Vis at 518 nm and ESI-ion trap MS with HPLC and nano-LC, respectively. Commercial blueberry juice (14 anthocyanins detected) was used to optimize chromatographic separation of analytes and other analysis parameters. Qualitative identification of anthocyanins was performed by comparing the recorded mass spectral data with those of published papers. The use of the same mobile phase composition in both techniques revealed that the miniaturized method exhibited shorter analysis time and higher sensitivity than narrow-bore chromatography. Good intra-day and day-to-day precision of retention time was obtained in both methods with values of RSD less than 3.4 and 0.8% for nano-LC and HPLC, respectively. Quantitative analysis was performed by external standard curve calibration of cyanidin-3-O-glucoside standard. Calibration curves were linear in the concentration ranges studied, 0.1-50 and 6-50 μg/mL for HPLC-UV/Vis and nano-LC-MS, respectively. LOD and LOQ values were good for both methods. In addition to commercial blueberry juice, qualitative and quantitative analysis of other juices (e.g. raspberry, sweet cherry and pomegranate) was performed. The optimized nano-LC-MS method allowed an easy and selective identification and quantification of anthocyanins in commercial fruit juices; it offered good results, shorter analysis time and reduced mobile phase volume with respect to narrow-bore HPLC. PMID:21246720

  12. Quantitative analysis of N-glycans from human alfa-acid-glycoprotein using stable isotope labeling and zwitterionic hydrophilic interaction capillary liquid chromatography electrospray mass spectrometry as tool for pancreatic disease diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Giménez, Estela, E-mail: estelagimenez@ub.edu [Department of Analytical Chemistry, University of Barcelona, Diagonal 647, E-08028 Barcelona (Spain); Balmaña, Meritxell [Biochemistry and Molecular Biology Unit, Department of Biology, University of Girona, Campus Montilivi s/n, 17071 Girona (Spain); Figueras, Joan [Department of Surgery, Dr. Josep Trueta University Hospital, IdlBGi, 17007 Girona (Spain); Fort, Esther [Digestive Unit, Dr. Josep Trueta University Hospital, 17007 Girona (Spain); Bolós, Carme de [Gastroesophagic Cancer Research Group, Research Programme in Cancer, Hospital del Mar Medical Research Institute (IMIM), Dr. Aiguader, 88, 08003 Barcelona (Spain); Sanz-Nebot, Victòria [Department of Analytical Chemistry, University of Barcelona, Diagonal 647, E-08028 Barcelona (Spain); Peracaula, Rosa [Biochemistry and Molecular Biology Unit, Department of Biology, University of Girona, Campus Montilivi s/n, 17071 Girona (Spain); Rizzi, Andreas [Institute of Analytical Chemistry, University of Vienna, Währinger Straße 38, A-1090 Vienna (Austria)

    2015-03-25

    Highlights: • The method enables relative quantitation of hAGP glycans from pathological samples • Pancreatic cancer samples clearly showed an increase of hAGP fucosylated glycans. • Fucosylated glycans could be potential biomarkers for diagnosing pancreatic cancer. • The established method could be extremely useful to find novel glycoprotein biomarkers - Abstract: In this work we demonstrate the potential of glycan reductive isotope labeling (GRIL) using [{sup 12}C]- and [{sup 13}C]-coded aniline and zwitterionic hydrophilic interaction capillary liquid chromatography electrospray mass spectrometry (μZIC-HILIC-ESI-MS) for relative quantitation of glycosylation variants in selected glycoproteins present in samples from cancer patients. Human α{sub 1}-acid-glycoprotein (hAGP) is an acute phase serum glycoprotein whose glycosylation has been described to be altered in cancer and chronic inflammation. However, it is not clear yet whether some particular glycans in hAGP can be used as biomarker for differentiating between these two pathologies. In this work, hAGP was isolated by immunoaffinity chromatography (IAC) from serum samples of healthy individuals and from those suffering chronic pancreatitis and different stages of pancreatic cancer, respectively. After de-N-glycosylation, relative quantitation of the hAGP glycans was carried out using stable isotope labeling and μZIC-HILIC-ESI-MS analysis. First, protein denaturing conditions prior to PNGase F digestion were optimized to achieve quantitative digestion yields, and the reproducibility of the established methodology was evaluated with standard hAGP. Then, the proposed method was applied to the analysis of the clinical samples (control vs. pathological). Pancreatic cancer samples clearly showed an increase in the abundance of fucosylated glycans as the stage of the disease increases and this was unlike to samples from chronic pancreatitis. The results gained here indicate the mentioned glycan in h

  13. Quantitative analysis of N-glycans from human alfa-acid-glycoprotein using stable isotope labeling and zwitterionic hydrophilic interaction capillary liquid chromatography electrospray mass spectrometry as tool for pancreatic disease diagnosis

    International Nuclear Information System (INIS)

    Highlights: • The method enables relative quantitation of hAGP glycans from pathological samples • Pancreatic cancer samples clearly showed an increase of hAGP fucosylated glycans. • Fucosylated glycans could be potential biomarkers for diagnosing pancreatic cancer. • The established method could be extremely useful to find novel glycoprotein biomarkers - Abstract: In this work we demonstrate the potential of glycan reductive isotope labeling (GRIL) using [12C]- and [13C]-coded aniline and zwitterionic hydrophilic interaction capillary liquid chromatography electrospray mass spectrometry (μZIC-HILIC-ESI-MS) for relative quantitation of glycosylation variants in selected glycoproteins present in samples from cancer patients. Human α1-acid-glycoprotein (hAGP) is an acute phase serum glycoprotein whose glycosylation has been described to be altered in cancer and chronic inflammation. However, it is not clear yet whether some particular glycans in hAGP can be used as biomarker for differentiating between these two pathologies. In this work, hAGP was isolated by immunoaffinity chromatography (IAC) from serum samples of healthy individuals and from those suffering chronic pancreatitis and different stages of pancreatic cancer, respectively. After de-N-glycosylation, relative quantitation of the hAGP glycans was carried out using stable isotope labeling and μZIC-HILIC-ESI-MS analysis. First, protein denaturing conditions prior to PNGase F digestion were optimized to achieve quantitative digestion yields, and the reproducibility of the established methodology was evaluated with standard hAGP. Then, the proposed method was applied to the analysis of the clinical samples (control vs. pathological). Pancreatic cancer samples clearly showed an increase in the abundance of fucosylated glycans as the stage of the disease increases and this was unlike to samples from chronic pancreatitis. The results gained here indicate the mentioned glycan in hAGP as a candidate

  14. Quantification of the Triazole Antifungal Compounds Voriconazole and Posaconazole in Human Serum or Plasma Using Liquid Chromatography Electrospray Tandem Mass Spectrometry (HPLC-ESI-MS/MS).

    Science.gov (United States)

    Molinelli, Alejandro R; Rose, Charles H

    2016-01-01

    Voriconazole and posaconazole are triazole antifungal compounds used in the treatment of fungal infections. Therapeutic drug monitoring of both compounds is recommended in order to guide drug dosing to achieve optimal blood concentrations. In this chapter we describe an HPLC-ESI-MS/MS method for the quantification of both compounds in human plasma or serum following a simple specimen preparation procedure. Specimen preparation consists of protein precipitation using methanol and acetonitrile followed by a cleanup step that involves filtration through a cellulose acetate membrane. The specimen is then injected into an HPLC-ESI-MS/MS equipped with a C18 column and separated over an acetonitrile gradient. Quantification of the drugs in the specimen is achieved by comparing the response of the unknown specimen to that of the calibrators in the standard curve using multiple reaction monitoring.

  15. Ethyl glucuronide in vitreous humor and blood postmortem specimens: analysis by liquid chromatography-electrospray tandem mass spectrometry and interpreting results of neo-formation of ethanol

    Directory of Open Access Journals (Sweden)

    Sara Vezzoli

    2015-03-01

    Full Text Available Introduction. The determination of ethyl glucuronide (EtG, a stable and sensitive marker that is specific to alcohol intake, finds many applications both in the forensic toxicology and clinical fields. Aim. The aim of the study is to examine the possibility of using a cadaveric biological matrix, vitreous humor (VH, to determine EtG as a marker of recent ethanol use. Methods. The blood, taken from the femoral vein, and the VH were obtained from 63 autopsy cases. Analysis of the EtG was performed using an LC/MS/MS system. Analyses of the ethanol and putrefaction biomarkers, such as acetaldehyde and n-propanol, were performed using the HS-GC/FID technique in both the matrices. Results. In 17 cases, both ethanol and EtG were absent in both matrices.Nineteen cases presented ethanol in blood from 0.05 to 0.30 g/L, EtG-Blood concentration from 0.02 to 3.27 mg/L, and EtG-VH concentration from 0.01 mg/L to 2.88 mg/L. Thirteen cases presented ethanol in blood > 0.05 g/L but EtG concentration in blood and VH lower than 0.01 mg/L, are part of these 8 samples presented acetic aldehyde and n- propanol in blood or VH, means identification of putrefaction indicators. Fourteen cases presented ethanol in blood > 0.46 and EtG concentration in blood and VH higher than 0.01 mg/L. Conclusions. The determination of EtG in biological material is important in those cases where the intake of ethanol appears doubtful, as it allows us to exclude the possibility of any post-mortem formation of ethanol.

  16. Ethyl glucuronide in vitreous humor and blood postmortem specimens: analysis by liquid chromatography-electrospray tandem mass spectrometry and interpreting results of neo-formation of ethanol

    OpenAIRE

    Sara Vezzoli; Marzia Bernini; Francesco De Ferrari

    2015-01-01

    Introduction. The determination of ethyl glucuronide (EtG), a stable and sensitive marker that is specific to alcohol intake, finds many applications both in the forensic toxicology and clinical fields. Aim. The aim of the study is to examine the possibility of using a cadaveric biological matrix, vitreous humor (VH), to determine EtG as a marker of recent ethanol use. Methods. The blood, taken from the femoral vein, and the VH were obtained from 63 autopsy cases. Analysis of the EtG was perf...

  17. Quantification of the Triazole Antifungal Compounds Voriconazole and Posaconazole in Human Serum or Plasma Using Liquid Chromatography Electrospray Tandem Mass Spectrometry (HPLC-ESI-MS/MS).

    Science.gov (United States)

    Molinelli, Alejandro R; Rose, Charles H

    2016-01-01

    Voriconazole and posaconazole are triazole antifungal compounds used in the treatment of fungal infections. Therapeutic drug monitoring of both compounds is recommended in order to guide drug dosing to achieve optimal blood concentrations. In this chapter we describe an HPLC-ESI-MS/MS method for the quantification of both compounds in human plasma or serum following a simple specimen preparation procedure. Specimen preparation consists of protein precipitation using methanol and acetonitrile followed by a cleanup step that involves filtration through a cellulose acetate membrane. The specimen is then injected into an HPLC-ESI-MS/MS equipped with a C18 column and separated over an acetonitrile gradient. Quantification of the drugs in the specimen is achieved by comparing the response of the unknown specimen to that of the calibrators in the standard curve using multiple reaction monitoring. PMID:26660172

  18. Reduction of in-source collision-induced dissociation and thermolysis of sulopenem prodrugs for quantitative liquid chromatography/electrospray ionization mass spectrometric analysis by promoting sodium adduct formation.

    Science.gov (United States)

    Wujcik, Chad E; Kadar, Eugene P

    2008-10-01

    Six chromatographically resolved sulopenem prodrugs were monitored for their potential to undergo both in-source collision-induced dissociation (CID) and thermolysis. Initial Q1 scans for each prodrug revealed the formation of intense [Prodrug2 + H]+, [Prodrug2 + Na]+, [Prodrug + Na]+, and [Sulopenem + Na]+ ions. Non-adduct-associated sulopenem ([Sulopenem + H]+) along with several additional lower mass ions were also observed. Product ion scans of [Prodrug3 + Na]+ showed the retention of the sodium adduct in the collision cell continuing down to opening of the beta-lactam ring. In-source CID and temperature experiments were conducted under chromatographic conditions while monitoring several of the latter ion transitions (i.e., adducts, dimers and degradants/fragments) for a given prodrug. The resulting ion profiles indicated the regions of greatest stability for temperature and declustering potential (DP) that provided the highest signal intensity for each prodrug and minimized in-source degradation. The heightened stability of adduct ions, relative to their appropriate counterpart (i.e., dimer to dimer adduct and prodrug to prodrug adduct ions), was observed under elevated temperature and DP conditions. The addition of 100 microM sodium to the mobile phase further enhanced the formation of these more stable adduct ions, yielding an optimal [Prodrug + Na]+ ion signal at temperatures from 400 to 600 degrees C. A clinical liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay for sulopenem prodrug PF-04064900 in buffered whole blood was successfully validated using sodium-fortified mobile phase and the [PF-04064900 + Na]+ ion for quantitation. A conservative five-fold increase in sensitivity from previously validated preclinical assays using the [PF-04064900 + H]+ precursor ion was achieved.

  19. Simultaneous determination of quetiapine and three metabolites in human plasma by high-performance liquid chromatography electrospray ionization mass spectrometry%高效液相色谱-电喷雾电离质谱联用法同时测定人血浆中喹硫平及其三个代谢产物

    Institute of Scientific and Technical Information of China (English)

    李坤艳; 程泽能; 李鑫; 白雪莲; 张毕奎; 王峰; 李焕德

    2004-01-01

    AIM: To develop a high performance liquid chromatography-electrospray mass spectrometry (HPLC-MS/ESI)method for simultaneous determination of quetiapine and its sulfoxide-, 7-hydroxy-, 7-hydroxy-N-dealkyl-metabolites in human plasma. METHODS: The HPLC separation of the compounds was performed on a Kromasil C18, (5 μm, 4.6 mm× 150 mm) column, using water (formic acid: 1.70 mmol/L, ammonium acetate: 5.8 mmol/L)-acetonitrile (65:35) as mobile phase, with a flow-rate of 0.95 mL/min. The compounds were ionized in the electrospray ionization (ESI) ion source of the mass spectrometer and detected in the selected ion recording (SIR) mode. The samples were extracted using solid-phase extraction columns. RESULTS: The calibration curves were linear in the ranges of 10-2000 μg/L for quetiapine, 1-200 μg/L for its metabolites, respectively. The average extraction recoveries for all the four samples were above 85 %. The methodology recoveries were much higher than 95 %. The intra-day and inter-day RSD are less than 15 %. CONCLUSION: The method is accurate, sensitive, and simple for study of pharmacokinetics and metabolic mechanism of quetiapine in patients at therapeutic dose.

  20. Optimization of the Extraction of Anthocyanins from the Fruit Skin of Rhodomyrtus tomentosa (Ait. Hassk and Identification of Anthocyanins in the Extract Using High-Performance Liquid Chromatography-Electrospray Ionization-Mass Spectrometry (HPLC-ESI-MS

    Directory of Open Access Journals (Sweden)

    Yuan-Ming Sun

    2012-05-01

    Full Text Available Anthocyanins are naturally occurring polyphenols that impart bright color to fruits, vegetables and plants. In this study, the extraction of anthocyanins from freeze-dried fruit skin of downy rose-myrtle (Rhodomyrtus tomentosa (Ait. Hassk var. Gangren was optimized using response surface methodology (RSM. Using 60% ethanol containing 0.1% (v/v hydrochloric acid as extraction solvent, the optimal conditions for maximum yields of anthocyanin (4.358 ± 0.045 mg/g were 15.7:1 (v/w liquid to solid ratio, 64.38 °C with a 116.88 min extraction time. The results showed good fits with the proposed model for the anthocyanin extraction (R2 = 0.9944. Furthermore, the results of high-performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS analysis of the anthocyanins extracted from the fruit skin of downy rose-myrtle revealed the presence of five anthocyanin components, which were tentatively identified as delphinidin-3-glucoside, cyanidin-3-glucoside, peonidin-3-glucoside, petunidin-3-glucoside and malvidin-3-glucoside.

  1. Liquid chromatographic-mass spectrometric analysis of glucuronide-conjugated anabolic steroid metabolites: method validation and interlaboratory comparison

    NARCIS (Netherlands)

    Hintikka, L.; Kuuranne, T.; Leinonen, A.; Thevis, M.; Schanzer, W.; Halket, J.; Cowan, D.; Grosse, J.; Hemmersbach, P.; Nielen, M.W.F.; Kostiainen, R.

    2008-01-01

    Liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method for simultaneous and direct detection of 12 glucuronide-conjugated anabolic androgenic steroid (AAS) metabolites in human urine is described. The compounds selected were the main metabolites detected in huma

  2. Simultaneous determination of seven flavonoids in Epimedium by liquid chromatography-tandem mass spectrometry method

    Institute of Scientific and Technical Information of China (English)

    Cai Sheng Wu; Bao Lin Guo; Yu Xin Sheng; Jin Lan Zhang

    2008-01-01

    In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoids, namely epimedin A, epimedin B, epimedin C, icariin, sagittatoside B, 2"-0-rhamnosyl icariside II, and baohuoside I in Epimedium from different sources.

  3. Identification of active compounds and their metabolites by high-performance liquid chromatography/electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry from Xiao-xu-ming decoction (XXMD).

    Science.gov (United States)

    Wang, Yilin; Ding, Chunguang; Du, Kehe; Xiao, Yao; Wu, Caisheng; Zhang, Jinlan; Qin, Hailin; Du, Guanhua

    2009-09-01

    Xiao-xu-ming decoction (XXMD) prescription is a traditional Chinese prescription that has been widely used to treat theoplegia and the sequela of theoplegia. Modern pharmacological research has also indicated that the active fraction from XXMD is able to treat cardiovascular diseases and Alzheimer's disease. In the study reported here, high-performance liquid chromatography coupled with Fourier transform ion cyclotron resonance mass spectrometry (HPLC/FTICR-MS) was developed to identify active compounds and their metabolites after oral administration of active fraction from Xiao-xu-ming decoction to rats, using parent mass list triggered data-dependent multiple-stage mass analysis at a resolving power of 100,000 in the external calibration mode. The mass accuracies obtained for full-scan MS were within 2 ppm in most cases. Fifteen constituents were identified in the active fraction from XXMD and the biological samples of rats. The fragmentation behaviors of these constituents were summarized which would be helpful for structural characterization. The profiles of the constituents in the active fraction and biological samples of rats were obtained which provided us with much information for a better understanding of the chemical basis of the pharmacologic actions of XXMD.

  4. Glycerophospholipid analysis of Eastern red bat (Lasiurus borealis) hair by electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Pannkuk, Evan L; McGuire, Liam P; Gilmore, David F; Savary, Brett J; Risch, Thomas S

    2014-03-01

    Pilosebaceous units found in the mammalian integument are composed of a hair follicle, the proximal portion of the hair shaft, a sebaceous gland, and the erector pili muscle. Pilosebaceous units release protective oils, or sebum, by holocrine secretion onto skin and hair through rupturing of sebocytes. Sebum is composed largely of polar and neutral lipids including glycerolipids, free fatty acids, sterols, wax esters, sterol esters, and squalene. In addition to these lipid classes, there is a small proportion of ionic/anionic glycerophospholipids (GPs). Composition of GPs on hair is rarely addressed despite their broad biological activities as signaling molecules and membrane stability. Furthermore, knowledge on GP composition in bats is lacking. Bat GP composition is important to document due to GP roles ranging from decreasing drag during migration to interaction with the integumentary microbiome. In this study, we analyzed GP molecular composition with liquid chromatography electrospray ionization tandem mass spectrometry and compared GP content to previous literature. A total of 152 GPs were detected. Broad GP classes identified include lysophosphatidylcholine, phosphatidylcholine (PC), lysophosphatidylethanolamine, phosphatidylethanolamine, phosphatidylinositol, phosphatidylserine, phosphatidic acid, and phosphatidylglycerol, with PC being the most abundant class. The acyl components were consistent with fatty acid methyl esters and triacylglyceride moieties found in Eastern red bat sebum. Glycerophospholipid proportions of the hair surface were different from a previous study on bat lung surfactants. This study determined the broad class and molecular species of bat sebum GPs that may be used in future ecological studies in vespertilionid bats. PMID:24532214

  5. [Determination of 25 quinolones in cosmetics by liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Lin, Li; Zhang, Yi; Tu, Xiaoke; Xie, Liqi; Yue, Zhenfeng; Kang, Haining; Wu, Weidong; Luo, Yao

    2015-03-01

    An analytical method was developed for the simultaneous determination of 25 quinolones, including danofloxacin mesylate, enrofloxacin, flumequine, oxloinic acid, ciprofloxacin, sarafloxacin, nalidixic acid, norfloxacin, and ofloxacin etc in cosmetics using direct extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). Cosmetic sample was extracted by acidified acetonitrile, defatted by n-hexane and separated on Poroshell EC-C18 column with gradient elution program using acetonitrile and water (both containing 0. 1% formic acid) as the mobile phases and analyzed by LC-ESI-MS/MS under the positive mode using multiple reaction monitoring (MRM). The interference of matrix was reduced by the matrix-matched calibration standard curve. The method showed good linearities over the range of 1-200 mg/kg for the 25 quinolones with good linear correlation coefficients (r ≥ 0.999). The method detection limit of the 25 quinolones was 1.0 mg/kg, and the recoveries of all analytes in lotion, milky and cream cosmetics matrices ranged from 87.4% to 105% at the spiked levels of 1, 5 and 10 mg/kg with the relative standard deviations (RSD) of 4.54%-19.7% (n = 6). The results indicated that this method is simple, fast and credible, and suitable for the simultaneous determination of the quinolones in the above three types of cosmetics.

  6. 女贞子化学成分的UPLC-ESI-Q-TOF-MS分析%Analysis on chemical components of Ligustrum lucidum by ultra performance liquid chromatography-electrospray ionization-quadrupole-time of flight-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    蒋叶娟; 姚卫峰; 张丽; 丁安伟

    2012-01-01

    目的:采用UPLC-ESI-Q-TOF-MS技术对女贞子中的化学成分进行定性分析.方法:采用ACQUITY UPLC BEHC18色谱柱(2.1mm×100 mm,1.7 μm),以乙腈-0.1%甲酸溶液为流动相梯度洗脱;质谱使用ESI离子源,正离子与负离子模式下采集数据.结果:通过正、负离子质谱信息及元素组成分析并结合对照品与相关文献数据对照,共鉴定出14个化合物.结论:通过超高效液相色谱分离,质谱测定相对分子质量及相关文献数据信息检索确定女贞子中的化学成分,为阐明女贞子的药效物质基础提供有力的证据.%Objective: To make a qualitative analysis on chemical components in Ligustrum lucidum by UPLC-ESI-Q-TOF-MS. Method; ACQUITY UPLC BEH C18 (2. 1 mm × 100 mm, 1. 7 μm) column was adopted, with methyl cyanides-0. 1% formic acid as the mobile phase for gradient elution; ESI ion source was used for mass spectra, and data were collected in positive and negative mode. Result: Fourteen compounds of L lucidum were identified by analyzing positive and negative ion mass spectra information and element composition and comparing controls with data from relevant literature. Conclusion: After the separation by ultra high performance liquid chromatography, relative molecular mass was determined by mass spectra, and chemical compounds in L. lucidum were determined by information search through relevant literature data, in order to provide powerful therapeutic material basis for L. lucidum.

  7. Peptide profiling of Internet-obtained Cerebrolysin using high performance liquid chromatography - electrospray ionization ion trap and ultra high performance liquid chromatography - ion mobility - quadrupole time of flight mass spectrometry.

    Science.gov (United States)

    Gevaert, Bert; D'Hondt, Matthias; Bracke, Nathalie; Yao, Han; Wynendaele, Evelien; Vissers, Johannes Petrus Cornelis; De Cecco, Martin; Claereboudt, Jan; De Spiegeleer, Bart

    2015-09-01

    Cerebrolysin, a parenteral peptide preparation produced by controlled digestion of porcine brain proteins, is an approved nootropic medicine in some countries. However, it is also easily and globally available on the Internet. Nevertheless, until now, its exact chemical composition was unknown. Using high performance liquid chromatography (HPLC) coupled to ion trap and ultra high performance liquid chromatography (UHPLC) coupled to quadrupole-ion mobility-time-of-flight mass spectrometry (Q-IM-TOF MS), combined with UniProt pig protein database search and PEAKS de novo sequencing, we identified 638 unique peptides in an Internet-obtained Cerebrolysin sample. The main components in this sample originate from tubulin alpha- and beta-chain, actin, and myelin basic protein. No fragments of known neurotrophic factors like glial cell-derived neurotrophic factor (GDNF), neurotrophin nerve growth factor (NGF), brain-derived neurotrophic factor (BDNF), and ciliary neurotrophic factor (CNTF) were found, suggesting that the activities reported in the literature are likely the result of new, hitherto unknown cryptic peptides with nootropic properties. PMID:26017115

  8. Peptide profiling of Internet-obtained Cerebrolysin using high performance liquid chromatography - electrospray ionization ion trap and ultra high performance liquid chromatography - ion mobility - quadrupole time of flight mass spectrometry.

    Science.gov (United States)

    Gevaert, Bert; D'Hondt, Matthias; Bracke, Nathalie; Yao, Han; Wynendaele, Evelien; Vissers, Johannes Petrus Cornelis; De Cecco, Martin; Claereboudt, Jan; De Spiegeleer, Bart

    2015-09-01

    Cerebrolysin, a parenteral peptide preparation produced by controlled digestion of porcine brain proteins, is an approved nootropic medicine in some countries. However, it is also easily and globally available on the Internet. Nevertheless, until now, its exact chemical composition was unknown. Using high performance liquid chromatography (HPLC) coupled to ion trap and ultra high performance liquid chromatography (UHPLC) coupled to quadrupole-ion mobility-time-of-flight mass spectrometry (Q-IM-TOF MS), combined with UniProt pig protein database search and PEAKS de novo sequencing, we identified 638 unique peptides in an Internet-obtained Cerebrolysin sample. The main components in this sample originate from tubulin alpha- and beta-chain, actin, and myelin basic protein. No fragments of known neurotrophic factors like glial cell-derived neurotrophic factor (GDNF), neurotrophin nerve growth factor (NGF), brain-derived neurotrophic factor (BDNF), and ciliary neurotrophic factor (CNTF) were found, suggesting that the activities reported in the literature are likely the result of new, hitherto unknown cryptic peptides with nootropic properties.

  9. An algorithmic approach to automated high-throughput identification of disulfide connectivity in proteins using tandem mass spectrometry.

    Science.gov (United States)

    Lee, Timothy; Singh, Rahul; Yen, Ten-Yang; Macher, Bruce

    2007-01-01

    Knowledge of the pattern of disulfide linkages in a protein leads to a better understanding of its tertiary structure and biological function. At the state-of-the-art, liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) can produce spectra of the peptides in a protein that are putatively joined by a disulfide bond. In this setting, efficient algorithms are required for matching the theoretical mass spaces of all possible bonded peptide fragments to the experimentally derived spectra to determine the number and location of the disulfide bonds. The algorithmic solution must also account for issues associated with interpreting experimental data from mass spectrometry, such as noise, isotopic variation, neutral loss, and charge state uncertainty. In this paper, we propose a algorithmic approach to high-throughput disulfide bond identification using data from mass spectrometry, that addresses all the aforementioned issues in a unified framework. The complexity of the proposed solution is of the order of the input spectra. The efficacy and efficiency of the method was validated using experimental data derived from proteins with with diverse disulfide linkage patterns.

  10. Simultaneous Determination and Pharmacokinetic Study of Protocatechuic Aldehyde and Its Major Active Metabolite Protocatechuic Acid in Rat Plasma by Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Wang, Xiangyang; Yan, Kaijing; Ma, Xiaohui; Li, Wei; Chu, Yang; Guo, Jiahua; Li, Shuming; Zhou, Shuiping; Zhu, Yonghong; Liu, Changxiao

    2016-05-01

    A very simple and selective high-performance liquid chromatography electrospray ionization tandem mass spectrometry (LC-MS-MS) method was developed for simultaneous determination and pharmacokinetic study of protocatechuic aldehyde (PAL) and its active metabolite protocatechuic acid (PCA). The method involves a simple liquid-liquid extraction with ethyl acetate. The separation was performed on a Hypersil GOLD C18column (2.1 × 150 mm, 3.0 µm; particle, Thermo, USA) with isocratic elution using a mobile phase consisted of methanol and water (containing 0.1% formic acid) at a flow rate of 0.2 mL/min. The detection of target compounds was done by using low-energy collision dissociation tandem mass spectrometry (CID-MS-MS) using the selective reaction monitoring scan mode. The method was linear for all analytes over the investigated range for all correlation coefficients greater than 0.9950. The lower limits of quantification were 2.0 ng/mL for PAL and PCA. The intra- and interday precisions (relative standard deviation, RSD %) were <6.84 and 5.54%, and the accuracy (relative error, RE %) was between -2.85 and 0.74% (n= 6). The developed method was applied to study the pharmacokinetics of PAL and its major active metabolite PCA in rat plasma after oral and intravenous administration of PAL. PMID:26969682

  11. Determination of putrescine, cadaverine, spermidine and spermine in different chemical matrices by high performance liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (HPLC-ESI-ITMS/MS).

    Science.gov (United States)

    Ibarra, Alan Alexander González; Wrobel, Katarzyna; Escobosa, Alma Rosa Corrales; Elguera, Julio Cesar Torres; Garay-Sevilla, Ma Eugenia; Wrobel, Kazimierz

    2015-10-01

    The goal of this work was to establish a simple HPLC-ESI-ITMS/MS procedure, suitable for the determination of four common aliphatic polyamines in two different types of biological matrices. To this end, 1,6-diaminohexane was used as the internal standard (IS) and 4-fluoro-3-nitrobenzenotrifluoride (FNBT) as the derivatizing agent. Formation of fully derivatized compounds was confirmed by high resolution ESI-QTOFMS and MS/MS analysis. Reversed phase chromatographic separation was carried out by gradient elution with 0.1% (v/v) formic acid and methanol. In a positive ESI mode, the following pairs of precursor/quantifier ions were used for multiple reaction monitoring: 467.4/261.0 for PUT, 481.2/461.1 for CAD, 713.7/261.0 for SPD, 959.8/507.2 for SPM and 495.3/475.2 for IS. On-column instrumental detection limits of four polyamines were in the range 0.62-2.14fmol (0.039-0.215ng/ml). Versatility was demonstrated by analyzing plant extracts and human urine; prior to derivatization, all samples were cleaned-up by dichloromethane extraction. The evaluated signal suppression/enhancement was in the range 82.3-115.4% and the percentage recoveries obtained in the method of standard addition were in the range 83.7-114.4%. Statistically significant differences in polyamines concentrations were found in garden cress exposed to Cd(II) versus control seedlings (t-test, p<0.05); results obtained for urine from healthy volunteers and diabetic patients at different clinical conditions suggested possible utility of free polyamines as biomarkers of progressive diabetes.

  12. Interpretation of tandem mass spectra of posttranslationally modified peptides

    DEFF Research Database (Denmark)

    Bunkenborg, J.; Matthiesen, R.

    2013-01-01

    Tandem mass spectrometry provides a sensitive means of analyzing the amino acid sequence of peptides and modified peptides by providing accurate mass measurements of precursor and fragment ions. Modern mass spectrometry instrumentation is capable of rapidly generating many thousands of tandem mas...

  13. Determination of endocrine-disrupting compounds in drinking waters by fast liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Magi, Emanuele; Scapolla, Carlo; Di Carro, Marina; Liscio, Camilla

    2010-09-01

    Growing attention has been recently paid to safety of food and drinking water, making necessary the adoption of policies for water sources protection and the development of sensitive and rapid analytical methods to identify micropollutants. Endocrine-disrupting compounds (EDCs) have emerged as a major issue as they alter the functioning of the endocrine system. Since ingestion of EDCs via food is considered the major exposure route, there is a growing interest in understanding EDC fate during drinking water treatment and in monitoring potential contamination of surface waters and groundwaters. In this work, a fast liquid chromatography-electrospray ionization-tandem mass spectrometry method was developed for the determination of 4-n-nonylphenol (NP), bisphenol A (BPA), estrone (E1), 17β-estradiol (E2) and 17α-ethinylestradiol (EE2) in drinking waters. In the literature analytical articles seldom provide details regarding fragmentation pathways. In this paper spectra of the five EDCs in negative ESI were interpreted with the support of accurate mass spectra acquired by a quadrupole time-of-flight instrument; fragmentation pathways were also proposed. The chromatographic separation of EDCs was optimized on a Pinnacle DB Biphenylic column with a water-acetonitrile gradient. Quantitative analysis was performed in multiple reaction monitoring (MRM) mode using bisphenol A-d(16) (BPA-d(16)) as internal standard; calibration curves showed good correlation coefficients (0.9989-0.9997). All figures of merit of the method were satisfactory; limits of detection were in the range 0.2-0.4 ng/ml. The method was applied to the determination of the analytes in waters sampled by polar organic chemical integrative samplers in a drinking water treatment plant. Rather low concentration of BPA, NP and E1 were measured in the inlet, while none of the considered EDCs was detected in the outlet.

  14. Characterization of gallotannins from Astronium species by flow injection analysis- electrospray ionization-ion trap-tandem mass spectrometry and matrix-assisted laser desorption/ionization time-of- flight mass spectrometry.

    Science.gov (United States)

    da Silva, Viviane Cândida; Napolitano, Assunta; Eletto, Daniela; Rodrigues, Clenilson Martins; Pizza, Cosimo; Vilegas, Wagner

    2011-01-01

    The species Astronium urundeuva (Allemao) Engl. and Astronium graveolens Jacq., which are used in Brazilian folk medicine to treat allergies, inflammation, diarrhea and ulcers, were investigated for their composition. The aim of this study was to define a rapid and reliable analytical approach, based on the flow-injection analysis-electrospray ionization-ion trap-tandem mass spectrometry (FIA-ESI-IT-MS-MS) and matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-ToF-MS), to investigate the full range of hydrolyzable tannins present in the extracts of these Astronium species. The MALDI-ToF-MS analysis allowed us to ascertain the presence of hydrolysable tannins in both Astronium species as a series of gallotannins with degrees of polymerization of 7 to 13 galloyl units. Moreover, the analysis by FIA-ESI-IT-MS-MS, as well as confirming this result and chemically defining gallotannins as galloylglucose compounds, highlighted the presence of further classes of hydrolysable tannins, such as hexahydrodiphenoyl esters of glucose and some gallic acid derivatives, providing information about their structure by a careful study of their fragmentation patterns. Finally, the evaluation of the number of positional isomers of gallotannins occurring in both Astronium species was obtained by high-performance liquid chromatography-electrospray ionization-ion trap mass spectrometry (HPLC/ESI-IT-MS). This is the first mass spectrometric evidence relating to the existence of gallotannins in Astronium genus. PMID:22006629

  15. High Mass Accuracy Phosphopeptide Identification Using Tandem Mass Spectra

    Directory of Open Access Journals (Sweden)

    Rovshan G. Sadygov

    2012-01-01

    Full Text Available Phosphoproteomics is a powerful analytical platform for identification and quantification of phosphorylated peptides and assignment of phosphorylation sites. Bioinformatics tools to identify phosphorylated peptides from their tandem mass spectra and protein sequence databases are important part of phosphoproteomics. In this work, we discuss general informatics aspects of mass-spectrometry-based phosphoproteomics. Some of the specifics of phosphopeptide identifications stem from the labile nature of phosphor groups and expanded peptide search space. Allowing for modifications of Ser, Thr, and Tyr residues exponentially increases effective database size. High mass resolution and accuracy measurements of precursor mass-to-charge ratios help to restrict the search space of candidate peptide sequences. The higher-order fragmentations of neutral loss ions enhance the fragment ion mass spectra of phosphorylated peptides. We show an example of a phosphopeptide identification where accounting for fragmentation from neutral loss species improves the identification scores in a database search algorithm by 50%.

  16. Liquid Chromatography Tandem Mass Spectrometry Method for Quantification of Solifenacin in Human Plasma and its Application to Bioequivalence Study

    Directory of Open Access Journals (Sweden)

    Nishant Paliwal

    2013-06-01

    Full Text Available A hasty, specific and robust assay based on liquid-liquid extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI MS-MS has been developed and validated for the quantitative analysis of Solifenacin ( a drug used for urinary incontinence in human plasma using Solifenacin D5 as internal standard (ISTD. The precursor to product ion transitions of m/z 363.20/110.10 and m/z 368.14/110.20 were used to measure the analyte and the ISTD, respectively. The method was validated in terms of selectivity, matrix effect, sensitivity, linearity, precision and accuracy, various stabilities (standard stock solution stability in refrigerator and at room temperature, stock dilution stability at refrigerator and room temperature, auto sampler stability, freeze thaw stability, long term stability- 65 o C ± 10o C & long term stability- 22 o C ± 5°C, reagent stability, bench top stability, dry extract stability, wet extract stability in refrigerator, effect of potentially interfering drugs, dilution integrity, recovery, lon suppression through infusion, and blood Stability. The mean percentage recovery of Solifenacin and the internal standard was 65.39 ± 3.646% and 66.24 ± 2.209% respectively. The assay exhibited a linear dynamic range of 0.200 to 30.361 ng mL-1. The RSD % of intra-day and inter-day assay was ≤15%. The application of this assay was demonstrated in a bioequivalence study and will be ideal for clinical pharmacokinetic studies in study population with as lower as 0.200 ng mL-1 analytical sensitivity and as little as 300 μL plasma sample.

  17. A strategy for identification and structural characterization of compounds from Gardenia jasminoides by integrating macroporous resin column chromatography and liquid chromatography-tandem mass spectrometry combined with ion-mobility spectrometry.

    Science.gov (United States)

    Wang, Lu; Liu, Shu; Zhang, Xueju; Xing, Junpeng; Liu, Zhiqiang; Song, Fengrui

    2016-06-24

    In this paper, an analysis strategy integrating macroporous resin (AB-8) column chromatography and high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) combined with ion mobility spectrometry (IMS) was proposed and applied for identification and structural characterization of compounds from the fruits of Gardenia jasminoides. The extracts of G. jasminoides were separated by AB-8 resin column chromatography combined with reversed phase liquid chromatography (C18 column) and detected by electrospray ionization tandem mass spectrometry. Additionally, ion mobility spectrometry (IMS) was employed as a supplementary separation technique to discover previously undetected isomers from the fruits of G. jasminoides. A total of 71 compounds, including iridoids, flavonoids, triterpenes, monoterpenoids, carotenoids and phenolic acids were identified by the characteristic high resolution mass spectrometry and the ESI-MS/MS fragmentations. In conclusion, the IMS-MS technique achieved the separation of isomers in crocin-3 and crocin-4 according to their acquired mobility drift times differing from classical analysis by mass spectrometry. The proposed strategy can be used as a highly sensitive and efficient procedure for identification and separation isomeric components in extracts of herbal medicines.

  18. A strategy for identification and structural characterization of compounds from Gardenia jasminoides by integrating macroporous resin column chromatography and liquid chromatography-tandem mass spectrometry combined with ion-mobility spectrometry.

    Science.gov (United States)

    Wang, Lu; Liu, Shu; Zhang, Xueju; Xing, Junpeng; Liu, Zhiqiang; Song, Fengrui

    2016-06-24

    In this paper, an analysis strategy integrating macroporous resin (AB-8) column chromatography and high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) combined with ion mobility spectrometry (IMS) was proposed and applied for identification and structural characterization of compounds from the fruits of Gardenia jasminoides. The extracts of G. jasminoides were separated by AB-8 resin column chromatography combined with reversed phase liquid chromatography (C18 column) and detected by electrospray ionization tandem mass spectrometry. Additionally, ion mobility spectrometry (IMS) was employed as a supplementary separation technique to discover previously undetected isomers from the fruits of G. jasminoides. A total of 71 compounds, including iridoids, flavonoids, triterpenes, monoterpenoids, carotenoids and phenolic acids were identified by the characteristic high resolution mass spectrometry and the ESI-MS/MS fragmentations. In conclusion, the IMS-MS technique achieved the separation of isomers in crocin-3 and crocin-4 according to their acquired mobility drift times differing from classical analysis by mass spectrometry. The proposed strategy can be used as a highly sensitive and efficient procedure for identification and separation isomeric components in extracts of herbal medicines. PMID:27208986

  19. Simultaneous determination of six bioactive flavonoids in Citri Reticulatae Pericarpium by rapid resolution liquid chromatography coupled with triple quadrupole electrospray tandem mass spectrometry.

    Science.gov (United States)

    Liu, E-Hu; Zhao, Pan; Duan, Li; Zheng, Guo-Dong; Guo, Long; Yang, Hua; Li, Ping

    2013-12-15

    A rapid resolution liquid chromatography/electrospray ionisation tandem mass spectrometry (RRLC-ESI-MS(n)) method has been firstly developed and validated for simultaneous determination of six bioactive flavonoids in Citri Reticulatae Pericarpium (CRP). The antiproliferative activities of the six flavonoids in CRP, namely naringin, hesperidin, nobiletin, 3,5,6,7,8,3',4'-heptamethoxyflavone, tangeretin and 5-hydroxy-6,7,8,3',4'-pentamethoxyflavone, were evaluated and compared by Cell Counting Kit-8 Assay. Quantification was carried out on an Agilent triple quadrupole LC-MS system using multiple reaction monitoring mode. The established method was successfully applied for determination of the six flavonoids in samples collected from different regions in China. Compared with the reported analytical methods, the RRLC-ESI-MS(n) method is powerful in quantitative analysis of multi-component in terms of time savings and sensitivity. Hierarchical cluster analysis (HCA) was also performed to differentiate and classify the samples based on the contents of the six characteristic flavonoids. The HCA results indicated that Citrus reticulata 'Chachi' samples could be easily distinguished from other CRP samples. The developed RRLC-ESI-MS(n) method combined with HCA might be utilised as a quality control method for CRP. PMID:23993574

  20. Development of a fast liquid chromatography-tandem mass spectrometry method for the determination of endocrine-disrupting compounds in waters.

    Science.gov (United States)

    Di Carro, Marina; Scapolla, Carlo; Liscio, Camilla; Magi, Emanuele

    2010-09-01

    A fast liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS-MS) method was developed to study five endocrine-disrupting compounds (4-n-nonylphenol, bisphenol A, estrone, 17β-estradiol and 17α-ethinylestradiol) in water. Different columns were tested; the chromatographic separation of the analytes was optimized on a Pinnacle DB biphenylic column with a water-acetonitrile gradient elution, which allowed the separation of the selected endocrine-disrupting compounds (EDCs) in less than 6 min. Quantitative analysis was performed in selected reaction monitoring (SRM) mode; two transitions were chosen for each compound, using the most abundant for quantitation. Calibration curves using bisphenol A-d (16) as internal standard were drawn, showing good correlation coefficients (0.9993-0.9998). All figures of merit of the method were satisfactory; limits of detection were in the low pg range for all analytes. The method was then applied to the determination of the analytes in real water samples: to this aim, polar organic chemical integrative samplers (POCIS) were deployed in the influent and in the effluent of a drinking water treatment plant in Liguria (Italy). The EDC level was rather low in the influent and negligible in the outlet, reflecting the expected function of the treatment plant.

  1. Comparative study of different fabric phase sorptive extraction sorbents to determine emerging contaminants from environmental water using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lakade, Sameer S; Borrull, Francesc; Furton, Kenneth G; Kabir, Abuzar; Fontanals, Núria; Marcé, Rosa Maria

    2015-11-01

    A new sorptive extraction technique, fabric phase sorptive extraction (FPSE), using different coating chemistries: non-polar sol-gel poly(dimethyldiphenylsiloxane) (PDMDPS), medium polar sol-gel poly(tetrahydrofuran) (PTHF), and polar sol-gel poly(ethylene glycol)-block-poly(propylene glycol)-block-poly(ethylene glycol) (PEG-PPG-PEG triblock) and sol-gel Carbowax 20 M were evaluated to extract a group of pharmaceuticals and personal care products (PPCPs) with wide range of polarity from environmental aqueous samples. Different parameters affecting FPSE such as sample pH, stirring speed, addition of salt, extraction time, sample volume, elution solvent and desorption time were optimized for each sorbent coated FPSE media. Under optimum conditions, FPSE media coated with sol-gel Carbowax 20 M provided the highest absolute recoveries (77-85%) for majority of the analytes with the exception of the most polar ones. Nevertheless, all four sorbents offered better recovery compared to the commercially available coating for stir-bar sorptive extraction based on Ethylene Glycol/Silicone (EG/Silicone). The method based on FPSE with sol-gel Carbowax 20 M media and liquid chromatography-(electrospray ionization) tandem mass spectrometry (LC-(ESI) MS/MS) was developed and validated for environmental water samples. Good apparent recoveries (41-80%), detection limits (1-50 ng L(-1)), repeatability (%RSD<15%, n=5) and reproducibility (%RSD<18%, n=5) were achieved. PMID:26452968

  2. Simultaneous determination of drugs of abuse and their main metabolites using pressurized liquid extraction and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Arbeláez, Paula; Borrull, Francesc; Maria Marcé, Rosa; Pocurull, Eva

    2014-07-01

    An analytical method based on pressurized liquid extraction (PLE) and liquid chromatography-(electrospray)-tandem mass spectrometry was developed for the simultaneous determination of nicotine, four drugs of abuse (opiates and alkaloids) and four of their main metabolites in sewage sludge. The optimum PLE conditions were: cell volume 11 mL, dichloromethane as extraction solvent, 5 min preheating time, 100 °C temperature, 1500 psi pressure, 60% flush volume, 1 cycle, 15 min static extraction time, 120 s purge time and sample weight 1g. Absolute recoveries for all compounds were between 25% and 65%. Data acquisition was done by selective reaction monitoring and the two most abundant product ions were used for confirmation. Limits of detection were lower than 10 μg/kg dry weight (d.w.) and limits of quantification were between 2.5 and 25 μg/kg (d.w.). The highest concentrations found in sludge samples from two sewage treatment plants were for nicotine and cocaine in the range of 23-173 μg/kg (d.w.) and 9-232 μg/kg (d.w.) respectively. PMID:24840416

  3. A sensitive and specific liquid chromatography/tandem mass spectrometry method for determination of pinaverium bromide in human plasma: application to a pharmacokinetic study in healthy volunteers.

    Science.gov (United States)

    Ren, Jin-Min; Zhao, Xi; Wang, Chuan-Ping; Sun, Qian; Yin, Li-Xin; Zhang, Zhi-Qing

    2011-12-01

    A sensitive and specific method using liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS) for the determination of pinaverium bromide in human plasma was developed and validated. Pinaverium bromide and an internal standard (paclitaxel) were isolated from plasma samples by precipitating plasma, and determined by LC-MS/MS in multiple-reaction monitoring mode. The main metabolite of pinaverium bromide and endogenous substances in plasma did not show any interference. The calibration curve was linear over the plasma concentration range of 10.0-10000.0 pg/mL with a correlation coefficient of 0.9979. The relative standard derivations intra- and inter-day at 30.0, 300.0 and 8000.0 pg/mL in plasma were less than 15%. The absolute recoveries of pinaverium bromide and the internal standard were 99.7-111.7 and 106.2%, respectively. The lower limit of quantitation was 10 pg/mL. The analytical method was successfully applied to study the pharmacokinetics of pinaverium bromide tablets in healthy Chinese volunteers. PMID:21308709

  4. Determination of estrogenic mycotoxins in environmental water samples by low-toxicity dispersive liquid-liquid microextraction and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Emídio, Elissandro Soares; da Silva, Claudia Pereira; de Marchi, Mary Rosa Rodrigues

    2015-04-24

    A novel, simple, rapid and eco-friendly method based on dispersive liquid-liquid microextraction using a bromosolvent was developed to determine six estrogenic mycotoxins (zearalenone, zearalanone, α-zearalanol, β-zearalanol, α-zearalenol and β-zearalenol) in water samples by liquid chromatography-electrospray ionization tandem mass spectrometry in the negative mode (LC-ESI-MS/MS). The optimal conditions for this method include the use of 100 μL bromocyclohexane as an extraction solvent (using a non-dispersion solvent), 10 mL of aqueous sample (adjusted to pH 4), a vortex extraction time of 2 min, centrifugation for 10 min at 3500 rpm and no ionic strength adjustment. The calibration function was linear and was verified by applying the Mandel fitting test with a 95% confidence level. No matrix effect was observed. According to the relative standard deviations (RSDs), the precision was better than 13% for the repeatability and intermediate precision. The average recoveries of the spiked compounds ranged from 81 to 118%. The method limits of detection (LOD) and quantification (LOQ) considering a 125-fold pre-concentration step were 4-20 and 8-40 ng L(-1), respectively. Next, the method was applied to the analysis of the environmental aqueous samples, demonstrating the presence of β-zearalanol and zearalanone in the river water samples.

  5. Quantitative determination of paclitaxel and its metabolites, 6α-hydroxypaclitaxel and p-3'-hydroxypaclitaxel, in human plasma using column-switching liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Yamaguchi, Hiroaki; Fujikawa, Asuka; Ito, Hajime; Tanaka, Nobuaki; Furugen, Ayako; Miyamori, Kazuaki; Takahashi, Natsuko; Ogura, Jiro; Kobayashi, Masaki; Yamada, Takehiro; Mano, Nariyasu; Iseki, Ken

    2013-04-01

    A column-switching liquid chromatography/electrospray ionization tandem mass spectrometry to determine paclitaxel and its metabolites, 6α-hydroxypaclitaxel and p-3'-hydroxypaclitaxel, in human plasma was developed. The analytical system had a Shim-Pack MAYI-ODS (10 × 4.6 mm i.d.) trapping column with deproteinization ability that concentrates analytes and removes water-soluble components. This method covered a linearity range of 5-5000 ng/mL of concentrations in plasma for paclitaxel, a range of 0.87-870 ng/mL for 6α-hydroxypaclitaxel and a range of 0.87-435 ng/mL for p-3'-hydroxypaclitaxel. The intra-day precision and inter-day precision of analysis were less than 11.1%, and the accuracy was within ±14.4% at concentrations of 5, 50, 500 and 5000 ng/mL for paclitaxel, 0.87, 8.7, 87 and 870 ng/mL for 6α-hydroxypaclitaxel, and 0.87, 8.7, 87 and 435 ng/mL for p-3'-hydroxypaclitaxel. The total run time was 30 min. Our method was successfully applied to clinical pharmacokinetic investigation. PMID:23018973

  6. Multiplex liquid chromatography-tandem mass spectrometry for the detection of wheat, oat, barley and rye prolamins towards the assessment of gluten-free product safety.

    Science.gov (United States)

    Manfredi, Anita; Mattarozzi, Monica; Giannetto, Marco; Careri, Maria

    2015-10-01

    Celiac patients should feel confident in the safety of foods labelled or expected to be gluten-free. In this context, a targeted proteomic approach based on liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) technique was proposed to assess the presence of celiotoxic cereals, namely wheat, oats, barley and rye, in raw and processed food products. To this aim, unique marker peptides were properly selected in order to distinguish between the different cereal types. A revised cocktail solution based on reducing and denaturing agents was exploited for prolamin extraction from raw and processed food; in addition, defatting with hexane was carried out for sample clean-up, allowing to largely reduce problems related to matrix effect. Method validation on fortified rice flour showed good analytical performance in terms of sensitivity (limits of detection in the 2-18 mg kg(-1) range). However, poor trueness was calculated for self-made incurred bread (between 3 and 30% depending on the peptide), probably due to baking processes, which reduce gluten extractability. Thus, it is evident that in the case of processed foods further insights into sample treatment efficiency and reference materials for protein calibration are required to obtain accurate gluten determination. Finally, the developed method was applied for the analysis of market food products, offering the possibility to discriminate among cereals, with good agreement with labelled ingredients for gluten-containing foodstuffs.

  7. Detection of triclocarban and two co-contaminating chlorocarbanilides in US aquatic environments using isotope dilution liquid chromatography tandem mass spectrometry

    International Nuclear Information System (INIS)

    The antimicrobial compound triclocarban (TCC; 3,4,4'-trichlorocarbanilide; CAS-bar 101-20-2) is a high-production-volume chemical, recently suggested to cause widespread contamination of US water resources. To test this hypothesis, we developed an isotope dilution liquid chromatography electrospray ionization tandem mass spectrometry method for ultratrace analysis of TCC (0.9ng/L detection limit) and analyzed low-volume water samples (200mL) along with primary sludge samples from across the United States. All river water samples (100%) collected downstream of wastewater treatment plants had detectable levels of TCC, as compared to 56% of those taken upstream. Concentrations of TCC (mean+/-standard deviation) downstream of sewage treatment plants (84+/-110ng/L) were significantly higher (Pw/w each) in technical grade TCC (99%). Application of the new method for chlorocarbanilide analysis yielded TCC occurrence data for 13 US states, confirmed the role of sewage treatment plants as environmental inputs of TCC, and identified DCC and TetraCC as previously unrecognized pollutants released into the environment alongside TCC

  8. Simultaneous Determination of Fifteen Constituents of Jitai Tablet Using Ultra High-Performance Liquid Chromatography Coupled with Triple Quadrupole Electrospray Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Shuping Wang

    2014-01-01

    Full Text Available An ultra-high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS method was developed for simultaneous determination of fifteen constituents in Jitai tablet (JTT, a complex Traditional Chinese Medicine prescription (TCMP used in treating opiate addiction. Benefitting from a small particle size (1.8 µm C18 column, accelerated analysis with satisfactory resolution, sensitivity and selectivity were achieved in a single run within 7 min with linear gradient elution of acetonitrile-0.1% (v/v formic acid in water. The analytical signal was obtained by multiple reaction monitoring transitions via electrospray ionization source operating in both positive and negative ionization mode. The approach was validated for linearity, sensitivity, precision, repeatability, stability and recovery. All analytes showed good linearity over a wide concentration range (r > 0.99. The method limits ranged from 0.03 ng/mL to 19.35 ng/mL which are sensitive enough for quality control studies. The developed method was successfully applied to the simultaneous determination of fifteen constituents in JTT. In conclusion, our experimental results demonstrate that UHPLC-ESI-MS/MS is a useful approach for the overall quality assessment of complex TCMPs.

  9. QuEChERS Method for the Determination of Pesticide Residues in Indonesian Green Coffee Beans using Liquid Chromatography Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Harmoko

    2015-12-01

    Full Text Available A method using QuEChERS sample preparation followed by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESIMS/MS was developed for quantitative determination of 14 pesticide residues in Indonesian green coffee beans. The European Standard Method EN 15662:2008 was modified to obtain an appropriate extraction and clean-up procedure for green coffee bean samples. Homogenous slurry samples were extracted with 1% acetic acid in acetonitrile and the extracts were cleaned up by a high pigment dispersive SPE. LC-ESI-MS/MS was operated in the MRM mode for two specific precursor-product ion transitions per target compound to obtain 4 identification points. Representative matrix-matched calibration curves were applied to compensate matrix effects. This method was validated according to the requirements of SANCO/12495/2011. Limits of detection (LODs and limits of quantification (LOQs were obtained in the ranges of 0.2-2.9 μg kg-1 and 0.8-9.7 μg kg-1 respectively, showing lower values than the maximum residu limits (MRLs set by importing countries. The method was applied to determine 14 pesticide residues in 181 Indonesian green coffee bean samples that were taken from different regions. Some pesticide residues were found in these samples and detected to be higher than the MRLs.

  10. Simultaneous Determination of Perfluorinated Compounds in Edible Oil by Gel-Permeation Chromatography Combined with Dispersive Solid-Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Yang, Lili; Jin, Fen; Zhang, Peng; Zhang, Yanxin; Wang, Jian; Shao, Hua; Jin, Maojun; Wang, Shanshan; Zheng, Lufei; Wang, Jing

    2015-09-30

    A simple analytical method was developed for the simultaneous analysis of 18 perfluorinated compounds (PFCs) in edible oil. The target compounds were extracted by acetonitrile, purified by gel permeation chromatography (GPC) and dispersive solid-phase extraction (DSPE) using graphitized carbon black (GCB) and octadecyl (C18), and analyzed by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ES-MS/MS) in negative ion mode. Recovery studies were performed at three fortification levels. The average recoveries of all target PFCs ranged from 60 to 129%, with an acceptable relative standard deviation (RSD) (1-20%, n = 3). The method detection limits (MDLs) ranged from 0.004 to 0.4 μg/kg, which was significantly improved compared with the existing liquid-liquid extraction and cleanup method. The method was successfully applied for the analysis of all target PFCs in edible oil samples collected from markets in Beijing, China, and the results revealed that C6-C10 perfluorocarboxylic acid (PFCAs) and C7 perfluorosulfonic acid PFSAs were the major PFCs detected in oil samples.

  11. Validation of a liquid chromatography-tandem mass spectrometry method for the identification and quantification of 5-nitroimidazole drugs and their corresponding hydroxy metabolites in lyophilised pork meat.

    Science.gov (United States)

    Zeleny, Reinhard; Harbeck, Stefan; Schimmel, Heinz

    2009-01-01

    A liquid chromatography-electrospray ionisation tandem mass spectrometry method for the simultaneous detection and quantitation of 5-nitroimidazole veterinary drugs in lyophilised pork meat, the chosen format of a candidate certified reference material, has been developed and validated. Six analytes have been included in the scope of validation, i.e. dimetridazole (DMZ), metronidazole (MNZ), ronidazole (RNZ), hydroxymetronidazole (MNZOH), hydroxyipronidazole (IPZOH), and 2-hydroxymethyl-1-methyl-5-nitroimidazole (HMMNI). The analytes were extracted from the sample with ethyl acetate, chromatographically separated on a C(18) column, and finally identified and quantified by tandem mass spectrometry in the multiple reaction monitoring mode (MRM) using matrix-matched calibration and (2)H(3)-labelled analogues of the analytes (except for MNZOH, where [(2)H(3)]MNZ was used). The method was validated in accordance with Commission Decision 2002/657/EC, by determining selectivity, linearity, matrix effect, apparent recovery, repeatability and intermediate precision, decision limits and detection capabilities, robustness of sample preparation method, and stability of extracts. Recovery at 1 microg/kg level was at 100% (estimates in the range of 101-107%) for all analytes, repeatabilities and intermediate precisions at this level were in the range of 4-12% and 2-9%, respectively. Linearity of calibration curves in the working range 0.5-10 microg/kg was confirmed, with r values typically >0.99. Decision limits (CCalpha) and detection capabilities (CCbeta) according to ISO 11843-2 (calibration curve approach) were 0.29-0.44 and 0.36-0.54 microg/kg, respectively. The method reliably identifies and quantifies the selected nitroimidazoles in the reconstituted pork meat in the low and sub-microg/kg range and will be applied in an interlaboratory comparison for determining the mass fraction of the selected nitroimidazoles in the candidate reference material currently developed at

  12. 重组L-天门冬酰胺酶II的液相色谱/电喷雾离子化质谱法分析%HIGH PERFORMANCE LIQUID CHROMATOGRAPHY / ELECTROSPRAY IONIZATON MASS SPECTROMETRIC CHARACTERIZATION OF RECOMBINANT L-ASPARAGINASE II

    Institute of Scientific and Technical Information of China (English)

    韩俊; 盛龙生; 杨仲元; 相秉仁; 安登魁

    2001-01-01

    AIM To characterize the primary structure of recombinant L-asparaginase II product. METHODS The molecular weight of the protein was measured by pneumatically-assisted electrospray ionization mass spectrometry with flow injection mode. Subsequently, tryptic peptide mapping was performed by high performance liquid chromatography on a C8 column with tandem UV and MS detection. An easy-to-use and simple denaturation process with trichloroacetic acid was conducted prior to tryptic digest so as to release the digest resistance from the protein structure. The amino acid sequences of the tryptic peptides were elucidated based on their in-source collision-induced dissociation spectra. RESULTS The measured molecular mass was different from the theoretical value. Three amino acid variations were unambiguously detected along the peptide backbone derived from the gene-encoding sequence. CONCLUSION This paper revealed that LC/ESI/MS had provided a promising and robust technique in primary structure analysis and quality control of DNA-derived recombinant protein pharmaceuticals.%目的 对基因重组L-天门冬酰胺酶II产品进行一级结构分析。方法 采用流动注射方式,电喷雾离子化质谱法测定分子量;三氯乙酸变性,胰蛋白酶水解后,HPLC测定肽图谱;结合质谱源内碰撞诱导解离技术,解析酶解肽段的氨基酸顺序。结果 分子量测定值与理论值不符,质谱解析表明样品中存在3个氨基酸变异现象,由此计算的分子量与测定值吻合。结论 液相色谱/电喷雾质谱法为基因重组蛋白质药物的一级结构分析和质量控制提供了新途径。

  13. An integrated strategy for rapid and accurate determination of free and cell-bound microcystins and related peptides in natural blooms by liquid chromatography-electrospray-high resolution mass spectrometry and matrix-assisted laser desorption/ionization time-of-flight/time-of-flight mass spectrometry using both positive and negative ionization modes.

    Science.gov (United States)

    Flores, Cintia; Caixach, Josep

    2015-08-14

    An integrated high resolution mass spectrometry (HRMS) strategy has been developed for rapid and accurate determination of free and cell-bound microcystins (MCs) and related peptides in water blooms. The natural samples (water and algae) were filtered for independent analysis of aqueous and sestonic fractions. These fractions were analyzed by MALDI-TOF/TOF-MS and ESI-Orbitrap-HCD-MS. MALDI, ESI and the study of fragmentation sequences have been provided crucial structural information. The potential of combined positive and negative ionization modes, full scan and fragmentation acquisition modes (TOF/TOF and HCD) by HRMS and high resolution and accurate mass was investigated in order to allow unequivocal determination of MCs. Besides, a reliable quantitation has been possible by HRMS. This composition helped to decrease the probability of false positives and negatives, as alternative to commonly used LC-ESI-MS/MS methods. The analysis was non-target, therefore covered the possibility to analyze all MC analogs concurrently without any pre-selection of target MC. Furthermore, archived data was subjected to retrospective "post-targeted" analysis and a screening of other potential toxins and related peptides as anabaenopeptins in the samples was done. Finally, the MS protocol and identification tools suggested were applied to the analysis of characteristic water blooms from Spanish reservoirs. PMID:26141269

  14. An integrated strategy for rapid and accurate determination of free and cell-bound microcystins and related peptides in natural blooms by liquid chromatography-electrospray-high resolution mass spectrometry and matrix-assisted laser desorption/ionization time-of-flight/time-of-flight mass spectrometry using both positive and negative ionization modes.

    Science.gov (United States)

    Flores, Cintia; Caixach, Josep

    2015-08-14

    An integrated high resolution mass spectrometry (HRMS) strategy has been developed for rapid and accurate determination of free and cell-bound microcystins (MCs) and related peptides in water blooms. The natural samples (water and algae) were filtered for independent analysis of aqueous and sestonic fractions. These fractions were analyzed by MALDI-TOF/TOF-MS and ESI-Orbitrap-HCD-MS. MALDI, ESI and the study of fragmentation sequences have been provided crucial structural information. The potential of combined positive and negative ionization modes, full scan and fragmentation acquisition modes (TOF/TOF and HCD) by HRMS and high resolution and accurate mass was investigated in order to allow unequivocal determination of MCs. Besides, a reliable quantitation has been possible by HRMS. This composition helped to decrease the probability of false positives and negatives, as alternative to commonly used LC-ESI-MS/MS methods. The analysis was non-target, therefore covered the possibility to analyze all MC analogs concurrently without any pre-selection of target MC. Furthermore, archived data was subjected to retrospective "post-targeted" analysis and a screening of other potential toxins and related peptides as anabaenopeptins in the samples was done. Finally, the MS protocol and identification tools suggested were applied to the analysis of characteristic water blooms from Spanish reservoirs.

  15. Determination of mepitiostane metabolites in human urine by liquid chromatography/tandem mass spectrometry for sports drug testing.

    Science.gov (United States)

    Okano, Masato; Sato, Mitsuhiko; Kojima, Asami; Kageyama, Shinji

    2015-11-10

    Mepitiostane (2α,3α-epithio-17β-(1-methoxycyclopentyloxy)-5α-androstane), which is a prodrug of epitiostanol (2α,3α-epitio-5α-androstane-17β-ol), is an epitiosteroid having anti-estrogenic and weak androgenic anabolic activities. The World Anti-Doping Agency prohibits the misuse of mepitiostane by athletes. Detection of the urinary metabolites epitiostanol sulfoxide and epitiostanol was studied using liquid chromatography/mass spectrometry (LC-MS) for doping control purposes. The use of LC-MS provided advantages over gas chromatography/mass spectrometry for detecting heat labile steroids because epitiostanol and epitiostanol sulfoxide were primarily pyrolized to 5α-androst-2-en-17β-ol. The method consists of enzymatic hydrolysis using β-glucuronidase (Escherichia coli), liquid-liquid extraction, and subsequent ultra-performance liquid chromatography/electrospray-tandem mass spectrometry. Epitiostanol sulfoxide was determined at urinary concentrations of 0.5-50ng/mL, recovery was 76.2-96.9%, and assay precision was calculated as 0.9-1.7% (intra-day) and 2.0-6.6% (inter-day). Epitiostanol was determined at urinary concentrations of 0.5-50ng/mL, recovery was 26.1-35.6% and assay precision was calculated as 4.1-4.6% (intra-day) and 3.3-8.5% (inter-day). The limits of detection for epitiostanol sulfoxide and epitiostanol were 0.05ng/mL and 0.10ng/mL, respectively. Epitiostanol sulfoxide and epitiostanol, as their gluco-conjugates, were identified in human urine after oral administration of 10mg mepitiostane. Epitiostanol sulfoxide and epitiostanol could be detected up to 48h and 24h after administration, respectively. The results showed that the detection window of epitiostanol is much shorter than that of epitiostanol sulfoxide. The LC-MS detection of urinary epitiostanol sulfoxide, a specific metabolite with a sulphur atom in its molecular structure, is likely to be able to identify the abuse of mepitiostane.

  16. Economics of tandem mass spectrometry screening of neonatal inherited disorders

    OpenAIRE

    Pandor, A; Eastham, J.; Chilcott, J.; Paisley, S; Beverley, C.

    2006-01-01

    Objectives: The aim of this study was to evaluate the cost-effectiveness of neonatal screening for phenylketonuria (PKU) and medium-chain acyl-coA dehydrogenase (MCAD) deficiency using tandem mass spectrometry (tandem MS). Methods: A systematic review of clinical efficacy evidence and cost-effectiveness modeling of screening in newborn infants within a UK National Health Service perspective was performed. Marginal costs, life-years gained, and cost-effectiveness acceptability curves are p...

  17. Optimized verification method for detection of an albumin-sulfur mustard adduct at Cys(34) using a hybrid quadrupole time-of-flight tandem mass spectrometer after direct plasma proteolysis.

    Science.gov (United States)

    John, Harald; Siegert, Markus; Gandor, Felix; Gawlik, Michael; Kranawetvogl, Andreas; Karaghiosoff, Konstantin; Thiermann, Horst

    2016-02-26

    The vesicant sulfur mustard (SM) is a banned chemical warfare agent that is controlled by the Organisation for the Prohibition of Chemical Weapons (OPCW). Bioanalytical procedures are mandatory for proving an alleged use and incorporation of SM into the body. We herein present the development and application of a novel optimized procedure suitable for qualitative verification analysis of plasma targeting the SM-adduct of human serum albumin (HSA) alkylated at the cysteine(34) residue. Diluted human plasma is directly mixed with pronase in an ultrafiltration device (10kDa cut-off) for proteolysis (4h, 37°C). Following ultrafiltration the filtrate is diluted and analyzed by microbore liquid chromatography-electrospray ionization high resolution tandem-mass spectrometry (μLC-ESI HR MS/MS) targeting the alkylated dipeptide hydroxyethylthioethyl-CysPro (HETE-CP). A hybrid quadrupole time-of-flight mass spectrometer provided high mass spectrometric resolution in the MS/MS mode enabling highest selectivity and sensitivity (lower limit of detection corresponding to 9.8nM SM in plasma). Kinetics of HETE-CP formation from heparin-, citrate-, and EDTA-plasma as well as serum are presented and the influence of different EDTA and pronase concentrations was characterized. The novel procedure was applied to plasma samples provided by the OPCW as well as to patientś plasma derived from real cases of SM-poisoning. PMID:26449527

  18. Interpretation of Tandem Mass Spectrometry (MSMS) Spectra for Peptide Analysis

    DEFF Research Database (Denmark)

    Hjernø, Karin; Højrup, Peter

    2015-01-01

    The aim of this chapter is to give a short introduction to peptide analysis by mass spectrometry (MS) and interpretation of fragment mass spectra. Through examples and guidelines we demonstrate how to understand and validate search results and how to perform de novo sequencing based on the often...... very complex fragmentation pattern obtained by tandem mass spectrometry (also referred to as MSMS). The focus is on simple rules for interpretation of MSMS spectra of tryptic as well as non-tryptic peptides....

  19. Determination of six microcystins and nodularin in surface and drinking waters by on-line solid phase extraction-ultra high pressure liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Beltrán, Eduardo; Ibáñez, María; Sancho, Juan Vicente; Hernández, Félix

    2012-11-30

    Microcystins and nodularin are cyclic peptides hepatotoxins produced by cyanobacterial genera (blue-green algae). Toxic cyanobacterial blooms are a worldwide problem, as reported in several countries, like China, Australia, or the United States. Therefore, it is necessary to develop sensitive and reliable analytical methodology to determine this type of toxins in water at parts per billion levels, or even lower. In this work, the potential of solid-phase extraction coupled on-line to ultra-high-pressure liquid chromatography/electrospray tandem mass spectrometry (SPE-UHPLC-MS/MS) has been investigated for the efficient quantification and confirmation of microcystins LR, RR, YR, LY, LW, LF and nodularin in surface and drinking water samples, at sub-ppb levels. The method developed involves the injection of only 1 mL of water sample into the on-line SPE-UHPLC-MS/MS system and allows the rapid determination of the compounds selected (8 min of chromatographic run), avoiding laborious sample treatment. The method was validated in surface and drinking water by means of recovery experiments at 0.25 and 1 μg L(-1). Average recoveries (n=5) ranged from 71 to 116%, with relative standard deviations (RSDs) lower than 15%. For microcystins LR, RR, YR and nodularin, a third level was also assayed (0.1 μg L(-1)) obtaining satisfactory data too. Limits of detection between 0.002 and 0.0405 μg L(-1) were estimated (0.0005 μg L(-1) for nodularin). The developed method was applied to the analysis of water samples collected in the province of Castellón (Spain). The acquisition of three MS/MS transitions for each compound allowed the unequivocal confirmation of positive samples, which was supported by the accomplishment of ion intensity ratios and retention time when compared with reference standards. PMID:23107121

  20. Development, validation, and application of a liquid chromatography-tandem mass spectrometry method for the determination of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol in human hair.

    Science.gov (United States)

    Yao, Li; Yang, Jun; Guan, Ya-feng; Liu, Bai-zhan; Zheng, Sai-jing; Wang, Wei-miao; Zhu, Xiao-lan; Zhang, Zhi-dan

    2012-11-01

    The tobacco-specific nitrosamine metabolite 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) is a valuable biomarker for human exposure to the carcinogenic nitrosamine 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) in tobacco and tobacco smoke. In this work, an efficient and sensitive method for the analysis of NNAL in human hair was developed and validated. The hair sample was extracted by NaOH solution digestion, purified by C(18) solid-phase extraction (SPE) and molecularly imprinted solid-phase extraction, further enriched by reverse-phase ultrasound-assisted dispersive liquid-liquid microextraction (USA-DLLME) into 1.0 % aqueous formic acid, and finally analyzed by liquid chromatography-electrospray ionization tandem mass spectrometry. Good linearity was obtained in the range of 0.24-10.0 pg/mg hair with a correlation coefficient of 0.9982, when 150 mg hair was analyzed. The limit of detection and lower limit of quantification were 0.08 and 0.24 pg/mg hair, respectively. Accuracies determined from hair samples spiked with three different levels of NNAL ranged between 87.3 and 107.7 %. Intra- and inter-day relative standard deviations varied from 4.1 to 8.5 % and from 6.9 to 11.3 %, respectively. Under the optimized conditions, an enrichment factor of 20 was obtained. Finally, the developed method was applied for the analysis of NNAL in smokers' hair. The proposed sample preparation procedure combining selectivity of two-step SPE and enrichment of DLLME significantly improves the purification and enrichment of the analyte and should be useful to analyze NNAL in hair samples for cancer risk evaluation and cancer prevention in relation to exposure to the tobacco-specific carcinogen NNK. PMID:22926132

  1. Determination of melamine in milk-based products and other food and beverage products by ion-pair liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ibanez, Maria; Sancho, Juan V. [Research Institute for Pesticides and Water, University Jaume I, E-12071, Castellon (Spain); Hernandez, Felix, E-mail: felix.hernandez@qfa.uji.es [Research Institute for Pesticides and Water, University Jaume I, E-12071, Castellon (Spain)

    2009-09-01

    This paper describes a fast method for the sensitive and selective determination of melamine in a wide range of food matrices, including several milk-based products. The method involves an extraction with aqueous 1% trichloroacetic acid before the injection of the 10-fold diluted extract into the liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) system, using labelled melamine as the internal standard. As melamine is present in aqueous media in the cationic form, the chromatographic separation in reversed-phase LC requires the use of anionic ion-pair reagents, such as tridecafluoroheptanoic acid (THFA). This allows a satisfactory chromatographic retention and peak shape in all the types of food samples investigated. The method has been validated in six food matrices (biscuit, dry pasta and four milk-based products) by means of recovery experiments in samples spiked at 1 and 5 mg kg{sup -1}. Average recoveries (n = 5) ranged from 77% to 100%, with excellent precision (RSDs lower than 5%) and limits of detection between 0.01 and 0.1 mg kg{sup -1}. In addition, accuracy and robustness of the method was proven in different soya-based matrices by means of quality control (QC) sample analysis. QC recoveries, at 1 and 2.5 mg kg{sup -1}, were satisfactory, ranging from 79% to 110%. The method developed in this work has been applied to the determination of melamine in different types of food samples. All detections were confirmed by acquiring two MS/MS transitions (127 > 85 for quantification; 127 > 68 for confirmation) and comparing their ion intensity ratio with that of reference standards. Accuracy of the method was also assessed by applying it to a milk-based product and a baking mix material as part of an EU proficiency test, in which highly satisfactory results were obtained.

  2. Liquid chromatography-tandem mass spectrometry and passive sampling: powerful tools for the determination of emerging pollutants in water for human consumption.

    Science.gov (United States)

    Mirasole, Cristiana; Di Carro, Marina; Tanwar, Shivani; Magi, Emanuele

    2016-09-01

    Among the wide range of emerging pollutants, perfluorinated compounds and various pharmaceuticals, such as nonsteroidal anti-inflammatory drugs, are showing growing concern. These contaminants can be found in freshwater ecosystems because of their incomplete removal during wastewater treatments so, their water solubility and poor degradability result in their continuous discharge and pseudo-persistent contamination. Usually, expected levels of these analytes are particularly low; therefore, sensitive and selective analytical techniques are required for their determination. Moreover, sampling and preconcentration are fundamental steps to reach the low detection limits required. The polar organic chemical integrative sampler (POCIS) represents a modern sampling approach that allows the in-situ preconcentration of ultra-trace pollutants. In this work, a fast liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method was developed for the determination of diclofenac, ketoprofen, mefenamic acid, naproxen, ibuprofen, perfluorooctanoic acid, perfluorooctanesulfonate and caffeine in water for human consumption. The chromatographic separation of analytes was achieved in less than 6 min. Quantitative analysis was performed in multiple reaction monitoring mode using ketoprofen-d3 as internal standard. Two different sites of Northern Italy were studied deploying POCIS for four weeks in both inlet and outlet of two drinking water treatment plants. The evaluation of time-weighted average concentration of contaminants was accomplished after the calibration of POCIS; to this aim, the sampling rate values for each compound were obtained by means of a simple calibration system developed in our laboratory. Ketoprofen, perfluorooctane sulfonate, perfluorooctanoate and caffeine were measured in both sites at the ng l(-1) level. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Hydrophilic interaction liquid chromatography-tandem mass spectrometry quantitative method for the cellular analysis of varying structures of gemini surfactants designed as nanomaterial drug carriers.

    Science.gov (United States)

    Donkuru, McDonald; Michel, Deborah; Awad, Hanan; Katselis, George; El-Aneed, Anas

    2016-05-13

    Diquaternary gemini surfactants have successfully been used to form lipid-based nanoparticles that are able to compact, protect, and deliver genetic materials into cells. However, what happens to the gemini surfactants after they have released their therapeutic cargo is unknown. Such knowledge is critical to assess the quality, safety, and efficacy of gemini surfactant nanoparticles. We have developed a simple and rapid liquid chromatography electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method for the quantitative determination of various structures of gemini surfactants in cells. Hydrophilic interaction liquid chromatography (HILIC) was employed allowing for a short simple isocratic run of only 4min. The lower limit of detection (LLOD) was 3ng/mL. The method was valid to 18 structures of gemini surfactants belonging to two different structural families. A full method validation was performed for two lead compounds according to USFDA guidelines. The HILIC-MS/MS method was compatible with the physicochemical properties of gemini surfactants that bear a permanent positive charge with both hydrophilic and hydrophobic elements within their molecular structure. In addition, an effective liquid-liquid extraction method (98% recovery) was employed surpassing previously used extraction methods. The analysis of nanoparticle-treated cells showed an initial rise in the analyte intracellular concentration followed by a maximum and a somewhat more gradual decrease of the intracellular concentration. The observed intracellular depletion of the gemini surfactants may be attributable to their bio-transformation into metabolites and exocytosis from the host cells. Obtained cellular data showed a pattern that grants additional investigations, evaluating metabolite formation and assessing the subcellular distribution of tested compounds.

  4. Determination of melamine in milk-based products and other food and beverage products by ion-pair liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    This paper describes a fast method for the sensitive and selective determination of melamine in a wide range of food matrices, including several milk-based products. The method involves an extraction with aqueous 1% trichloroacetic acid before the injection of the 10-fold diluted extract into the liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) system, using labelled melamine as the internal standard. As melamine is present in aqueous media in the cationic form, the chromatographic separation in reversed-phase LC requires the use of anionic ion-pair reagents, such as tridecafluoroheptanoic acid (THFA). This allows a satisfactory chromatographic retention and peak shape in all the types of food samples investigated. The method has been validated in six food matrices (biscuit, dry pasta and four milk-based products) by means of recovery experiments in samples spiked at 1 and 5 mg kg-1. Average recoveries (n = 5) ranged from 77% to 100%, with excellent precision (RSDs lower than 5%) and limits of detection between 0.01 and 0.1 mg kg-1. In addition, accuracy and robustness of the method was proven in different soya-based matrices by means of quality control (QC) sample analysis. QC recoveries, at 1 and 2.5 mg kg-1, were satisfactory, ranging from 79% to 110%. The method developed in this work has been applied to the determination of melamine in different types of food samples. All detections were confirmed by acquiring two MS/MS transitions (127 > 85 for quantification; 127 > 68 for confirmation) and comparing their ion intensity ratio with that of reference standards. Accuracy of the method was also assessed by applying it to a milk-based product and a baking mix material as part of an EU proficiency test, in which highly satisfactory results were obtained.

  5. Hydrophilic interaction liquid chromatography-tandem mass spectrometry quantitative method for the cellular analysis of varying structures of gemini surfactants designed as nanomaterial drug carriers.

    Science.gov (United States)

    Donkuru, McDonald; Michel, Deborah; Awad, Hanan; Katselis, George; El-Aneed, Anas

    2016-05-13

    Diquaternary gemini surfactants have successfully been used to form lipid-based nanoparticles that are able to compact, protect, and deliver genetic materials into cells. However, what happens to the gemini surfactants after they have released their therapeutic cargo is unknown. Such knowledge is critical to assess the quality, safety, and efficacy of gemini surfactant nanoparticles. We have developed a simple and rapid liquid chromatography electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method for the quantitative determination of various structures of gemini surfactants in cells. Hydrophilic interaction liquid chromatography (HILIC) was employed allowing for a short simple isocratic run of only 4min. The lower limit of detection (LLOD) was 3ng/mL. The method was valid to 18 structures of gemini surfactants belonging to two different structural families. A full method validation was performed for two lead compounds according to USFDA guidelines. The HILIC-MS/MS method was compatible with the physicochemical properties of gemini surfactants that bear a permanent positive charge with both hydrophilic and hydrophobic elements within their molecular structure. In addition, an effective liquid-liquid extraction method (98% recovery) was employed surpassing previously used extraction methods. The analysis of nanoparticle-treated cells showed an initial rise in the analyte intracellular concentration followed by a maximum and a somewhat more gradual decrease of the intracellular concentration. The observed intracellular depletion of the gemini surfactants may be attributable to their bio-transformation into metabolites and exocytosis from the host cells. Obtained cellular data showed a pattern that grants additional investigations, evaluating metabolite formation and assessing the subcellular distribution of tested compounds. PMID:27086283

  6. Analysis of major antioxidants from extracts of Myrmecodia pendans by UV/visible spectrophotometer, liquid chromatography/tandem mass spectrometry, and high-performance liquid chromatography/UV techniques

    Directory of Open Access Journals (Sweden)

    Adam Mekonnen Engida

    2015-06-01

    Full Text Available In the present work, heat reflux extraction with ethanol/water (80:20; v/v as the solvent was used to extract antioxidants from Myrmecodia pendans. The crude extract (CE was fractionated using hexane and ethyl acetate. Ethyl acetate fraction (EAF and aqueous fraction were collected. Antioxidant activity against 1,1-diphenyl-2-picrylhydrazyl-radical radical and ferric reducing power of the CE, EAF, and aqueous fraction were evaluated. EAF showed comparable antioxidant activity against 1,1-diphenyl-2-picrylhydrazyl-radical radical and ferric reducing power to those of the CE. UV/visible, liquid chromatography/electrospray ionization/tandem mass spectrometry, and high-performance liquid chromatography were employed for identifying the major antioxidant compounds in the EAF. Three major phenolic compounds (rosmarinic acid, procyanidin B1, and polymer of procyanidin B1 were identified. The first two compounds were confirmed and quantified by high-performance liquid chromatography using authentic standards, but confirmation of the third compound was hampered by a lack of commercial standard. Concentrations of rosmarinic acid and procyanidin B1 in the EAF were found to be 20.688 ± 1.573 mg/g dry sample and 3.236 ± 0.280 mg/g dry sample, respectively. All these three compounds are reported for the first time in sarang semut.

  7. Structural Characterization of Carbohydrates by Fourier Transform Tandem Mass Spectrometry

    OpenAIRE

    Zhou, Wen; Håkansson, Kristina

    2011-01-01

    Fourier transform tandem mass spectrometry (MS/MS) provides high mass accuracy, high sensitivity, and analytical versatility and has therefore emerged as an indispensable tool for structural elucidation of biomolecules. Glycosylation is one of the most common posttranslational modifications, occurring in ~50% of proteins. However, due to the structural diversity of carbohydrates, arising from non-template driven biosynthesis, achievement of detailed structural insight is highly challenging. T...

  8. Analysis of posttranslational modifications of proteins by tandem mass spectrometry

    DEFF Research Database (Denmark)

    Larsen, Martin Røssel; Trelle, Morten B; Thingholm, Tine E;

    2006-01-01

    -temporal distribution in cells and tissues. Most PTMs can be detected by protein and peptide analysis by mass spectrometry (MS), either as a mass increment or a mass deficit relative to the nascent unmodified protein. Tandem mass spectrometry (MS/MS) provides a series of analytical features that are highly useful for......Protein activity and turnover is tightly and dynamically regulated in living cells. Whereas the three-dimensional protein structure is predominantly determined by the amino acid sequence, posttranslational modification (PTM) of proteins modulates their molecular function and the spatial...

  9. Determination of neonicotinoids in Estonian honey by liquid chromatography-electrospray mass spectrometry.

    Science.gov (United States)

    Laaniste, Asko; Leito, Ivo; Rebane, Riin; Lõhmus, Rünno; Lõhmus, Ants; Punga, Fredrik; Kruve, Anneli

    2016-07-01

    The aim of the study was to provide a comprehensive overview of neonicotinoid pesticide residues in honey samples for a single country and compare the results with the import data for neonicotinoid pesticides. The levels of four neonicotinoid pesticides, namely thiamethoxam, imidacloprid, acetamiprid, and thiacloprid, were determined in 294 honey samples harvested from 2005 to 2013 from more than 200 locations in Estonia. For the analyzed honey samples, 27% contained thiacloprid, and its levels in all cases were below the maximum residue level set by the European Union. The other neonicotinoids were not detected. The proportion of thiacloprid-positive samples for different years correlates well with the data on thiacloprid imports into Estonia, indicating that honey contamination with neonicotinoids can be estimated based on the import data.

  10. Determination of potato glycoalkaloids using high-pressure liquid chromatography-electrospray ionisation/mass spectrometry.

    Science.gov (United States)

    Matsuda, Fumio; Morino, Keiko; Miyazawa, Haruna; Miyashita, Masahiro; Miyagawa, Hisashi

    2004-01-01

    A method for quantifying two toxic glycoalkaloids, alpha-solanine and alpha-chaconine, in potato (Solanum tuberosum) tuber tissue was developed using HPLC-electrospray ionisation (ESI)/MS. Potato samples were extracted with 5% aqueous acetic acid, and the extracts were subjected directly to HPLC-ESI/MS after filtration. By determining the intensities of the protonated molecules of alpha-solanine (m/z 868) and alpha-chaconine (m/z 852) using selected ion monitoring (positive ion mode), a sensitive assay was attained with detection limits of 38 and 14 ppb for the two glycoalkaloids, respectively. The high sensitivity and selectivity of MS detection effectively reduced the time of analysis thus enabling a high throughput assay of glycoalkaloids in potato tubers.

  11. Identification of phenolic compounds in strawberries by liquid chromatography electrospray ionization mass spectroscopy

    OpenAIRE

    Seeram, Navindra P.; Lee, R; Scheuller, H S; Heber, D

    2006-01-01

    Strawberry (Fragaria x ananassa Duch.) fruits contain phenolic compounds that have antioxidant, anticancer, antiatherosclerotic and anti-neurodegenerative properties. Identification of food phenolics is necessary since their nature, size, solubility, degree and position of glycosylation and conjugation influence their absorption, distribution, metabolism and excretion in humans. Freeze-dried whole strawberry fruit powder and strawberry fruit extracts were analyzed by liquid chromatography ele...

  12. Multiresidue Analysis of Seven Anticoagulant Rodenticides by high-performance liquid chromatography/electrospray/mass spectrometry

    Science.gov (United States)

    Mice and rat populations are commonly controlled by two classes of rodenticide anticoagulants, coumarins and indandiones. However, poisoning of nontarget animals also often occurs. For cases such as these, a rapid, multi-residue method, which provides positive confirmation for both classes of antico...

  13. Determination of ribavirin in human serum using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    van der Lijke, Henk; Alffenaar, Jan-Willem C; Kok, Wim Th; Greijdanus, Ben; Uges, Donald R A

    2012-01-15

    A method has been developed for the determination of ribavirin in human serum for therapeutic drug monitoring purposes, using liquid chromatography electrospray ionization mass spectrometry. Separation was obtained with a mobile phase gradient starting and ending in 100% aqueous conditions using a Waters Atlantis® T3 column (100×2mm, 3μm). The entire sample preparation consisted of dilution, followed by ultrafiltration. From the clear ultrafiltrate 5μL was injected on the LC-MS/MS system. The calibration curves were linear in the range of 0.2-10mg/L with within-run and between-run precisions (CVs) in the range of 0-10%. The method was validated with respect to specificity, selectivity, linearity, accuracy, precision, recovery and stability and meets the requirements of the FDA. The method was extensively tested for matrix effects by determining the variation of the slopes of calibration curves in different sources of serum and plasma. This method is suitable for the determination of ribavirin in human serum for therapeutic drug monitoring. PMID:22265514

  14. Tandem mass spectrometry data quality assessment by self-convolution

    Directory of Open Access Journals (Sweden)

    Tham Wai

    2007-09-01

    Full Text Available Abstract Background Many algorithms have been developed for deciphering the tandem mass spectrometry (MS data sets. They can be essentially clustered into two classes. The first performs searches on theoretical mass spectrum database, while the second based itself on de novo sequencing from raw mass spectrometry data. It was noted that the quality of mass spectra affects significantly the protein identification processes in both instances. This prompted the authors to explore ways to measure the quality of MS data sets before subjecting them to the protein identification algorithms, thus allowing for more meaningful searches and increased confidence level of proteins identified. Results The proposed method measures the qualities of MS data sets based on the symmetric property of b- and y-ion peaks present in a MS spectrum. Self-convolution on MS data and its time-reversal copy was employed. Due to the symmetric nature of b-ions and y-ions peaks, the self-convolution result of a good spectrum would produce a highest mid point intensity peak. To reduce processing time, self-convolution was achieved using Fast Fourier Transform and its inverse transform, followed by the removal of the "DC" (Direct Current component and the normalisation of the data set. The quality score was defined as the ratio of the intensity at the mid point to the remaining peaks of the convolution result. The method was validated using both theoretical mass spectra, with various permutations, and several real MS data sets. The results were encouraging, revealing a high percentage of positive prediction rates for spectra with good quality scores. Conclusion We have demonstrated in this work a method for determining the quality of tandem MS data set. By pre-determining the quality of tandem MS data before subjecting them to protein identification algorithms, spurious protein predictions due to poor tandem MS data are avoided, giving scientists greater confidence in the

  15. Interpretation of tandem mass spectra obtained from cyclic nonribosomal peptides.

    Science.gov (United States)

    Liu, Wei-Ting; Ng, Julio; Meluzzi, Dario; Bandeira, Nuno; Gutierrez, Marcelino; Simmons, Thomas L; Schultz, Andrew W; Linington, Roger G; Moore, Bradley S; Gerwick, William H; Pevzner, Pavel A; Dorrestein, Pieter C

    2009-06-01

    Natural and non-natural cyclic peptides are a crucial component in drug discovery programs because of their considerable pharmaceutical properties. Cyclosporin, microcystins, and nodularins are all notable pharmacologically important cyclic peptides. Because these biologically active peptides are often biosynthesized nonribosomally, they often contain nonstandard amino acids, thus increasing the complexity of the resulting tandem mass spectrometry data. In addition, because of the cyclic nature, the fragmentation patterns of many of these peptides showed much higher complexity when compared to related counterparts. Therefore, at the present time it is still difficult to annotate cyclic peptides MS/MS spectra. In this current work, an annotation program was developed for the annotation and characterization of tandem mass spectra obtained from cyclic peptides. This program, which we call MS-CPA is available as a web tool (http://lol.ucsd.edu/ms-cpa_v1/Input.py). Using this program, we have successfully annotated the sequence of representative cyclic peptides, such as seglitide, tyrothricin, desmethoxymajusculamide C, dudawalamide A, and cyclomarins, in a rapid manner and also were able to provide the first-pass structure evidence of a newly discovered natural product based on predicted sequence. This compound is not available in sufficient quantities for structural elucidation by other means such as NMR. In addition to the development of this cyclic annotation program, it was observed that some cyclic peptides fragmented in unexpected ways resulting in the scrambling of sequences. In summary, MS-CPA not only provides a platform for rapid confirmation and annotation of tandem mass spectrometry data obtained with cyclic peptides but also enables quantitative analysis of the ion intensities. This program facilitates cyclic peptide analysis, sequencing, and also acts as a useful tool to investigate the uncommon fragmentation phenomena of cyclic peptides and aids the

  16. Cloud parallel processing of tandem mass spectrometry based proteomics data.

    Science.gov (United States)

    Mohammed, Yassene; Mostovenko, Ekaterina; Henneman, Alex A; Marissen, Rob J; Deelder, André M; Palmblad, Magnus

    2012-10-01

    Data analysis in mass spectrometry based proteomics struggles to keep pace with the advances in instrumentation and the increasing rate of data acquisition. Analyzing this data involves multiple steps requiring diverse software, using different algorithms and data formats. Speed and performance of the mass spectral search engines are continuously improving, although not necessarily as needed to face the challenges of acquired big data. Improving and parallelizing the search algorithms is one possibility; data decomposition presents another, simpler strategy for introducing parallelism. We describe a general method for parallelizing identification of tandem mass spectra using data decomposition that keeps the search engine intact and wraps the parallelization around it. We introduce two algorithms for decomposing mzXML files and recomposing resulting pepXML files. This makes the approach applicable to different search engines, including those relying on sequence databases and those searching spectral libraries. We use cloud computing to deliver the computational power and scientific workflow engines to interface and automate the different processing steps. We show how to leverage these technologies to achieve faster data analysis in proteomics and present three scientific workflows for parallel database as well as spectral library search using our data decomposition programs, X!Tandem and SpectraST.

  17. A workflow for multiclass determination of 256 pesticides in essential oils by liquid chromatography tandem mass spectrometry using evaporation and dilution approaches: Application to lavandin, lemon and cypress essential oils.

    Science.gov (United States)

    Fillatre, Yoann; Rondeau, David; Daguin, Antoine; Communal, Pierre-Yves

    2016-01-01

    This paper describes the determination of 256 multiclass pesticides in cypress and lemon essential oils (EOs) by the way of liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) analysis using the scheduled selected reaction monitoring mode (sSRM) available on a hybrid quadrupole linear ion trap (QLIT) mass spectrometer. The performance of a sample preparation of lemon and cypress EOs based on dilution or evaporation under nitrogen assisted by a controlled heating were assessed. The best limits of quantification (LOQs) were achieved with the evaporation under nitrogen method giving LOQs≤10µgL(-1) for 91% of the pesticides. In addition the very satisfactory results obtained for recovery, repeatability and linearity showed that for EOs of relatively low evaporation temperature, a sample preparation based on evaporation under nitrogen is well adapted and preferable to dilution. By compiling these results with those previously published by some of us on lavandin EO, we proposed a workflow dedicated to multiresidue determination of pesticides in various EOs by LC-ESI/sSRM. Among the steps involved in this workflow, the protocol related to mass spectrometry proposes an alternative confirmation method to the classical SRM ratio criteria based on a sSRM survey scan followed by an information-dependent acquisition using the sensitive enhanced product ion (EPI) scan to generate MS/MS spectra then compared to a reference. The submitted workflow was applied to the case of lemon EOs samples highlighting for the first time the simultaneous detection of 20 multiclass pesticides in one EO. Some pesticides showed very high concentration levels with amounts greatly exceeding the mgL(-1).

  18. Non-Target Screening of Veterinary Drugs Using Tandem Mass Spectrometry on SmartMass

    Science.gov (United States)

    Xia, Bing; Liu, Xin; Gu, Yu-Cheng; Zhang, Zhao-Hui; Wang, Hai-Yan; Ding, Li-Sheng; Zhou, Yan

    2013-05-01

    Non-target screening of veterinary drugs using tandem mass spectrometric data was performed on the SmartMass platform. This newly developed software uses the characteristic fragmentation patterns (CFP) to identify chemicals, especially those containing particular substructures. A mixture of 17 sulfonamides was separated by ultra performance liquid chromatography (UPLC), and SmartMass was used to process the tandem mass spectrometry (MS/MS) data acquired on an Orbitrap mass spectrometer. The data were automatically extracted, and each sulfonamide was recognized and analyzed with a prebuilt analysis rule. By using this software, over 98 % of the false candidate structures were eliminated, and all the correct structures were found within the top 10 of the ranking lists. Furthermore, SmartMass could also be used to identify slightly modified contraband drugs and metabolites with simple prebuilt rules. [Figure not available: see fulltext.

  19. Quantitative Comparison of Tandem Mass Spectra Obtained on Various Instruments

    Science.gov (United States)

    Bazsó, Fanni Laura; Ozohanics, Oliver; Schlosser, Gitta; Ludányi, Krisztina; Vékey, Károly; Drahos, László

    2016-08-01

    The similarity between two tandem mass spectra, which were measured on different instruments, was compared quantitatively using the similarity index (SI), defined as the dot product of the square root of peak intensities in the respective spectra. This function was found to be useful for comparing energy-dependent tandem mass spectra obtained on various instruments. Spectral comparisons show the similarity index in a 2D "heat map", indicating which collision energy combinations result in similar spectra, and how good this agreement is. The results and methodology can be used in the pharma industry to design experiments and equipment well suited for good reproducibility. We suggest that to get good long-term reproducibility, it is best to adjust the collision energy to yield a spectrum very similar to a reference spectrum. It is likely to yield better results than using the same tuning file, which, for example, does not take into account that contamination of the ion source due to extended use may influence instrument tuning. The methodology may be used to characterize energy dependence on various instrument types, to optimize instrumentation, and to study the influence or correlation between various experimental parameters.

  20. The application of tandem mass spectrometry to neonatal screening for inherited disorders of intermediary metabolism.

    Science.gov (United States)

    Chace, Donald H; Kalas, Theodore A; Naylor, Edwin W

    2002-01-01

    This review is intended to serve as a practical guide for geneticists to current applications of tandem mass spectrometry to newborn screening. By making dried-blood spot analysis more sensitive, specific, reliable, and inclusive, tandem mass spectrometry has improved the newborn detection of inborn errors of metabolism. Its innate ability to detect and quantify multiple analytes from one prepared blood specimen in a single analysis permits broad recognition of amino acid, fatty acid, and organic acid disorders. An increasing number of newborn screening programs are either utilizing or conducting pilot studies with tandem mass spectrometry. It is therefore imperative that the genetics community be familiar with tandem mass spectrometric newborn screening.

  1. Approach to the study of flavone di-C-glycosides by high performance liquid chromatography-tandem ion trap mass spectrometry and its application to characterization of flavonoid composition in Viola yedoensis.

    Science.gov (United States)

    Cao, Jie; Yin, Chengle; Qin, Yan; Cheng, Zhihong; Chen, Daofeng

    2014-10-01

    The mass spectrometric (MS) analysis of flavone di-C-glycosides has been a difficult task due to pure standards being unavailable commercially and to that the reported relative intensities of some diagnostic ions varied with MS instruments. In this study, five flavone di-C-glycoside standards from Viola yedoensis have been systematically studied by high performance liquid chromatography-electrospray ionization-tandem ion trap mass spectrometry (HPLC-ESI-IT-MS(n)) in the negative ion mode to analyze their fragmentation patterns. A new MS(2) and MS(3) hierarchical fragmentation for the identification of the sugar nature (hexoses or pentoses) at C-6 and C-8 is presented based on previously established rules of fragmentation. Here, for the first time, we report that the MS(2) and MS(3) structure-diagnostic fragments about the glycosylation types and positions are highly dependent on the configuration of the sugars at C-6 and C-8. The base peak ((0,2) X1 (0,2) X(2)(-) ion) in MS(3) spectra of di-C-glycosides could be used as a diagnostic ion for flavone aglycones. These newly proposed fragmentation behaviors have been successfully applied to the characterization of flavone di-C-glycosides found in V. yedoensis. A total of 35 flavonoid glycosides, including 1 flavone mono-C-hexoside, 2 flavone 6,8-di-C-hexosides, 11 flavone 6,8-di-C-pentosides, 13 flavone 6,8-C-hexosyl-C-pentosides, 5 acetylated flavone C-glycosides and 3 flavonol O-glycosides, were identified or tentatively identified on the base of their UV profiles, MS and MS(n) (n = 5) data, or by comparing with reference substances. Among these, the acetylated flavone C-glycosides were reported from V. yedoensis for the first time.

  2. Loading of free radicals on the functional graphene combined with liquid chromatography-tandem mass spectrometry screening method for the detection of radical-scavenging natural antioxidants.

    Science.gov (United States)

    Wang, Guoying; Shi, Gaofeng; Chen, Xuefu; Chen, Fuwen; Yao, Ruixing; Wang, Zhenju

    2013-11-13

    A novel free radical reaction combined with liquid chromatography electrospray ionization tandem mass spectrometry (FRR-LC-PDA-ESI/APCI-MS/MS) screening method was developed for the detection and identification of radical-scavenging natural antioxidants. Functionalized graphene was prepared by chemical method for loading free radicals (superoxide radical, peroxyl radical and PAHs free radical). Separation was performed with and without a preliminary exposure of the sample to specific free radicals on the functionalized graphene, which can facilitate reaction kinetics (charge transfers) between free radicals and potential antioxidants. The difference in chromatographic peak areas is used to identify potential antioxidants. The structure of the antioxidants in one sample (Swertia chirayita) is identified using MS/MS and comparison with standards. Thirteen compounds were found to possess potential antioxidant activity, and their free radical-scavenging capacities were investigated. The thirteen compounds were identified as 1,3,5-trihydroxyxanthone-8-O-β-D-glucopyranoside (PD1), norswertianin (PD2), 1,3,5,8-tetrahydroxyxanthone (PD3), 3, 3', 4', 5, 8-penta hydroxyflavone-6-β-D-glucopyranosiduronic acid-6'-pentopyranose-7-O-glucopyranoside (PD4), 1,5,8-trihydroxy-3-methoxyxanthone (PD5), swertiamarin (PS1), 2-C-β-D-glucopyranosyl-1,3,7-trihydroxylxanthone (PS2), 1,3,7-trihydroxylxanthone-8-O-β-D-glucopyranoside (PL1), 1,3,8-trihydroxyl xanthone-5-O-β-D-glucopyranoside (PL2), 1,3,7-trihydroxy-8-methoxyxanthone (PL3), 1,2,3-trihydroxy-7,8-dimethoxyxanthone (PL4), 1,8-dihydroxy-2,6-dimethoxy xanthone (PL5) and 1,3,5,8-tetramethoxydecussatin (PL6). The reactivity and SC50 values of those compounds were investigated, respectively. PD4 showed the strongest capability for scavenging PAHs free radical; PL4 showed prominent scavenging capacities in the lipid peroxidation processes; it was found that all components in S. chirayita exhibited weak reactivity in the superoxide

  3. TANDEM

    Data.gov (United States)

    Federal Laboratory Consortium — The Tandem Van de Graaff facility provides researchers with beams of more than 40 different types of ions - atoms that have been stripped of their electrons. One of...

  4. Simulation of Two Dimensional Electrophoresis and Tandem Mass Spectrometry for Teaching Proteomics

    Science.gov (United States)

    Fisher, Amanda; Sekera, Emily; Payne, Jill; Craig, Paul

    2012-01-01

    In proteomics, complex mixtures of proteins are separated (usually by chromatography or electrophoresis) and identified by mass spectrometry. We have created 2DE Tandem MS, a computer program designed for use in the biochemistry, proteomics, or bioinformatics classroom. It contains two simulations--2D electrophoresis and tandem mass spectrometry.…

  5. Simultaneous determination of five phenolic components and paeoniflorin in rat plasma by liquid chromatography-tandem mass spectrometry and pharmacokinetic study after oral administration of Cerebralcare granule(®).

    Science.gov (United States)

    Wang, Xiang-yang; Ma, Xiao-hui; Li, Wei; Chu, Yang; Guo, Jia-hua; Li, Shu-ming; Wang, Jun-mei; Zhang, Hong-chao; Zhou, Shui-ping; Zhu, Yong-hong

    2013-12-01

    A simple, sensitive and selective high-performance liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method was developed for simultaneous determination and pharmacokinetic study of six active components, protocatechuic acid, chlorogenic acid, caffeic acid, ferulic acid rosmarinic acid and paeoniflorin in rat plasma after oral administration of Cerebralcare granule(®) for the first time. The method involves a simple liquid-liquid extraction with ethyl acetate. The separation was performed on a Luna C18 column (2.0×100mm i.d., 3.0μm, particle, Phenomenex, USA) with gradient elution using a mobile phase composed of acetonitrile and water (containing 0.1% formic acid) at a flow rate of 0.2ml/min. Electrospray ionization (ESI) in negative ion mode and selective reaction monitoring (SRM) was used for the quantification of six active components and internal standard (IS, Chloroamphenicol). The method was linear for all analytes over investigated range with all correlation coefficients greater than 0.9914. The lower limits of quantification (LLOQ) were 1.0ng/ml for protocatechuic acid, 1.0ng/ml for chlorogenic acid, 1.0ng/ml for caffeic acid, 5.0ng/ml for ferulic acid, 1.5ng/ml for rosmarinic acid and 6.0ng/ml for paeoniflorin, respectively. The intra- and inter-day precisions (R.S.D.%) were less than 6.60% and 11.68%, and accuracy (RE %) between -3.26% and 1.13% (n=6). The developed method was applied for the first time to the pharmacokinetic study of protocatechuic acid, chlorogenic acid, caffeic acid, ferulic acid, rosmarinic acid and paeoniflorin in rat plasma after oral administration of Cerebralcare granule(®). PMID:23994763

  6. An evaluation of tandem mass spectrometry in drug metabolism studies.

    Science.gov (United States)

    Naylor, S; Kajbaf, M; Lamb, J H; Jahanshahi, M; Gorrod, J W

    1993-07-01

    The use of precursor ion and constant neutral loss scanning as a means of rapidly detecting drug metabolites is evaluated. Four clinically useful drugs, namely (i) cyclophosphamide, (ii) mifentidine, (iii) cimetropium bromide and (iv) haloperidol, were subjected to microsomal incubations to afford phase I metabolites. Aside from a minor clean-up procedure involving zinc sulfate precipitation of microsomal proteins and solid-phase extraction of metabolites using a Sep-pak C-18 cartridge, the mixtures were analysed directly by fast atom bombardment tandem mass spectrometry. It is demonstrated that such screening strategies are important in detecting novel metabolites. However, there are some problems associated with only using such methods, including (i) the possibility of not detecting metabolites that undergo unusual collision-induced dissociation fragmentation pathways, (ii) the non-detection of metabolites that have undergone metabolic change at unusual sites of reactivity, and (iii) production of artifacts derived from the parent drug by the primary ionization process. Examples are discussed that highlight both the strengths and weaknesses of such an approach.

  7. Installation of a tandem-type accelerator mass spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mizushima, Toshihiko; Togawa, Orihiko; Mizutani, Yoshihiko [Japan Atomic Energy Research Inst., Mutsu, Aomori (Japan). Mutsu Establishment; Kabuto, Shoji [Mutsu Marine Laboratory, Japan Marine Science Foundation, Mutsu, Aomori (Japan); Yamamoto, Tadatoshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2000-02-01

    Tandem-type accelerator mass spectrometer (hereinafter referred to as Tandetron) was installed at the Ominato Facility of Mutsu Establishment, JAERI in April, 1997. The objective of its installation is to investigate the mechanism of the mixing and circulation of seawater in the ocean, by collecting seawater samples around Japan and analyzing the horizontal and vertical distributions of {sup 14}C contained in the samples. The Tandetron consists of two lines to measure isotopic ratios of carbon and those of heavier iodine. The adjustment for the carbon line was finished and the measurements of seawater samples were started. The iodine line, on the other hand, is on the final step of its adjustment and performance tests are being carried out with a TOF (Time of Flight) detector. The iodine line will be used to analyze {sup 129}I released from a spent nuclear fuel reprocessing plant and other nuclear facilities. In this report, we summarize the status of installation of the carbon and iodine lines for the Tandetron. The report describes the situations of their adjustments until now, the outline of the Tandetron, tests of measurement performance, evaluation and inspection of shielding performance, problems and their solutions, and so on. (author)

  8. Identification of phenolic constituents in red chicory salads (Cichorium intybus) by high-performance liquid chromatography with diode array detection and electrospray ionisation tandem mass spectrometry.

    Science.gov (United States)

    Carazzone, Chiara; Mascherpa, Dora; Gazzani, Gabriella; Papetti, Adele

    2013-06-01

    Phenolic acids and flavonoids extracted from several types of Cichorium intybus var. silvestre salads ("Chioggia", "Treviso", "Treviso tardivo", and "Verona") were characterised by high-performance liquid chromatography-electrospray ionisation/mass spectrometry. Among the 64 compounds detected, several hydroxycinnamic acid derivatives including 8 mono- and dicaffeoylquinic acids, 3 tartaric acid derivatives, 31 flavonol and 2 flavone glycosides, as well as 10 anthocyanins were characterised based on UV spectra and MS(n) fragmentation patterns. Furthermore, several isomers of caffeic acid derivatives were distinguished for the first time by their specific mass spectral data. This is the first study reporting the glycosylation type and position of mono- and diglycosylated flavonoids in red salads. PMID:23411215

  9. Preprocessing of Tandem Mass Spectrometric Data Based on Decision Tree Classification

    Institute of Scientific and Technical Information of China (English)

    Jing-Fen Zhang; Si-Min He; Jin-Jin Cai; Xing-Jun Cao; Rui-Xiang Sun; Yan Fu; Rong Zeng; Wen Gao

    2005-01-01

    In this study, we present a preprocessing method for quadrupole time-of-flight(Q-TOF) tandem mass spectra to increase the accuracy of database searching for peptide (protein) identification. Based on the natural isotopic information inherent in tandem mass spectra, we construct a decision tree after feature selection to classify the noise and ion peaks in tandem spectra. Furthermore, we recognize overlapping peaks to find the monoisotopic masses of ions for the following identification process. The experimental results show that this preprocessing method increases the search speed and the reliability of peptide identification.

  10. Simultaneous determination of seven gestagens in kidney fats by Ultra Performance Convergence Chromatography tandem mass spectrometry

    NARCIS (Netherlands)

    Tao, Yanfei; Balzer-Rutgers, Paula; Stolker, A.A.M.; Chen, Dongmei; Yuan, Zonghui

    2015-01-01

    An ultra-performance convergence chromatography (UPC2) system coupled tandem mass spectrometry was successfully utilised to analyse chlormadinone acetate, delmadinone acetate, fluorogestone acetate, medroxyprogesterone acetate, megestrol acetate, melengestrol acetate, chlortestasterone acetate in

  11. Characterization of linear and branched polyacrylates by tandem mass spectrometry.

    Science.gov (United States)

    Chaicharoen, Kittisak; Polce, Michael J; Singh, Anirudha; Pugh, Coleen; Wesdemiotis, Chrys

    2008-10-01

    The unimolecular degradation of alkali-metal cationized polyacrylates with the repeat unit CH(2)CH(COOR) and a variety of ester pendants has been examined by tandem mass spectrometry. The fragmentation patterns resulting from collisionally activated dissociation depend sensitively on the size of the ester alkyl substituent (R). With small alkyl groups, as in poly(methyl acrylate), lithiated or sodiated oligomers (M) decompose via free-radical chemistry, initiated by random homolytic C-C bond cleavages along the polymer chain. The radical ions formed this way dissociate further by backbiting rearrangements and beta scissions to yield a distribution of terminal fragments with one of the original end groups and internal fragments with 2-3 repeat units. If the ester alkyl group bears three or more carbon atoms, cleavages within the ester moieties become the predominant decomposition channel. This distinct reactivity is observed if R = t-butyl, n-butyl, or the mesogenic group (CH(2))(11)-O-C(6)H(4)-C(6)H(4)-CN. The [M+alkali metal](+) ions of the latter polyacrylates dissociate largely by charge-remote 1,5-H rearrangements that convert COOR to COOH groups by expulsion of 1-alkenes. The acid groups may displace an alcohol unit from a neighboring ester pendant to form a cyclic anhydride, unless hindered by steric effects. Using atom transfer radical polymerization, hyperbranched polyacrylates were prepared carrying ester groups both within and between the branches. Unique alkenes and alcohols are cleaved from ester groups at the branching points, enabling determination of the branching architecture. PMID:18373231

  12. Revisiting hyper- and hypo-androgenism by tandem mass spectrometry.

    Science.gov (United States)

    Fanelli, Flaminia; Gambineri, Alessandra; Mezzullo, Marco; Vicennati, Valentina; Pelusi, Carla; Pasquali, Renato; Pagotto, Uberto

    2013-06-01

    Modern endocrinology is living a critical age of transition as far as laboratory testing and biochemical diagnosis are concerned. Novel liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays for steroid measurement in biological fluids have abundantly demonstrated their analytical superiority over immunometric platforms that until now have dominated the world of steroid hormones determination in clinical laboratories. One of the most useful applications of LC-MS/MS is in the hypogonadism and hyperandrogenism field: LC-MS/MS has proved particularly suitable for the detection of low levels of testosterone typical of women and children, and in general more reliable in accurately determining hypogonadal male levels. This technique also offers increased informative power by allowing multi-analytical profiles that give a more comprehensive picture of the overall hormonal asset. Several LC-MS/MS methods for testosterone have been published in the last decade, some of them included other androgen or more comprehensive steroid profiles. LC-MS/MS offers the concrete possibility of achieving a definitive standardization of testosterone measurements and the generation of widely accepted reference intervals, that will set the basis for a consensus on the diagnostic value of biochemical testing. The present review is aimed at summarizing technological advancements in androgen measurements in serum and saliva. We also provide a picture of the state of advancement of standardization of testosterone assays, of the redefinition of androgen reference intervals by novel assays and of studies using LC-MS/MS for the characterization and diagnosis of female hyperandrogenism and male hypogonadism.

  13. Determination of Epoxiconazole in Wheat and Soil Using Ultra-Performance Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry(UPLC-MS/MS)%超高效液相色谱-串联质谱法(UPLC-MS/MS)快速检测小麦和土壤中氟环唑的残留及消解

    Institute of Scientific and Technical Information of China (English)

    范玉; 田迎迎; 刘新刚; 董丰收; 徐军; 郑永权

    2013-01-01

    In order to know the degradation of epoxiconazole in wheat and soil clearly, a sensitive and effective method for the determination of epoxiconazole in wheat and soil using ultra-high performace liquid chromatographf UPLC-MS/MS) was established. Moreover, the degradation of epoxiconazole in wheat and soil in Shandong, Henan and Beijing Provinces was also investigated. The epoxiconazole residues were analyzed by UPLC-MS/MS under multiple reaction monitoring mode. The average recoveries using this method at three spiking levels(0.05 mg-kg-1, 0.5 mg-kg-1, 1.0 mg-kg-1) were also evaluated. The results indicated that recoveries ranged from 98.8% to 108.1% with variation coefficient (CV) in the range of 2.6%~6.7%(n=5) in soil, from 73.2%~84.4% with CV of 0.9%~4.6% in wheat plant and from 80.7%~82.4% with CV of 2.0%~7.8% in wheat, respectively. Meanwhile, a field experiment was also conducted to reveal the dynamics of epoxiconazole residues in wheat and soil in the three provinces. The results showed that the half life of epoxiconazole was 16.9 days, 21.3 days, 19.7 days in soil and 12.6 days, 9.2 days, 8.1 days in wheat plant in Shandong, Henan and Beijing respectively which showed that epoxiconazole belonged to non-persistent and easily degradable pesticide.%为了解氟环唑在小麦和土壤中的消解动态,建立了超高效液相色谱-串联四级杆质谱(UPLC-MS/MS)快速检测小麦及土壤中氟环唑残留的分析方法,并在山东、河南和北京开展了为期两年的小麦田间试验研究.不同浓度氟环唑(0.05、0.5、1.0 mg· kg-1)的添加回收率试验结果表明:在土壤中平均回收率为98.8%~108.1%,变异系数为2.6%~6.7%;在小麦植株中的平均回收率为73.2%~84.4%,变异系数为0.9%~4.6%;在小麦粒中的平均回收率为80.7%~82.4%,变异系数为2.0%~7.8%.氟环唑在山东、河南和北京三地的小麦和土壤中的消解动态研究结果表明,氟环唑在土壤中的消解半衰期分别为16.9、21.3、19.7 d,在小麦植株上的半衰期分别为12.6、9.2、8.1d,属于易降解农药.

  14. 液相色谱-串联质谱法测定头发中10种蛋白同化激素%Analysis of 10 Kinds of Anabolic Androgenic Steroids in Human Hair by High Performance Liquid Chromatography-Electrospray Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    严慧; 向平; 王萌烨; 沈保华; 沈敏

    2007-01-01

    建立了同时测定头发中10种蛋白同化激素液相色谱-串联质谱(LC/MS/MS)分析方法.头发样品经NaOH消解、戊烷液液提取后,用反相液相色谱分离,电喷雾正离子源进行离子化,用多反应监测方式(MRM)对这10种蛋白同化激素的母离子及子离子进行监测,三重四极杆质谱测定.10种蛋白同化激素的检出限为1~20 ng/g;相对标准偏差(RSD)为1.72%~ 13.77%;回收率为38.20%~110.38%;线性回归系数(R2)为0.9958~0.9999.本方法简便快速、灵敏度高、专属性强,可满足在兴奋剂检测或毒物分析中对毛发中蛋白同化激素测定的要求.

  15. High-Speed Tandem Mass Spectrometric in Situ Imaging by Nanospray Desorption Electrospray Ionization Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lanekoff, Ingela T.; Burnum-Johnson, Kristin E.; Thomas, Mathew; Short, Joshua TL; Carson, James P.; Cha, Jeeyeon; Dey, Sudhansu K.; Yang, Pengxiang; Prieto Conaway, Maria C.; Laskin, Julia

    2013-10-15

    Nanospray desorption electrospray ionization (nano-DESI) combined with tandem mass spectrometry (MS/MS), high-resolution mass analysis (m/m=17,500 at m/z 200), and rapid spectral acquisition enabled simultaneous imaging and identification of more than 300 molecules from 92 selected m/z windows (± 1 Da) with a spatial resolution of better than 150 um. Uterine sections of implantation sites on day 6 of pregnancy were analyzed in the ambient environment without any sample pre-treatment. MS/MS imaging was performed by scanning the sample under the nano-DESI probe at 10 um/s while acquiring higher-energy collision-induced dissociation (HCD) spectra for a targeted inclusion list of 92 m/z values at a rate of ~6.3 spectra/s. Molecular ions and their corresponding fragments, separated using high-resolution mass analysis, were assigned based on accurate mass measurement. Using this approach, we were able to identify and image both abundant and low-abundance isobaric species within each m/z window. MS/MS analysis enabled efficient separation and identification of isobaric sodium and potassium adducts of phospholipids. Furthermore, we identified several metabolites associated with early pregnancy and obtained the first 2D images of these molecules.

  16. Plasma Desorption Mass Spectrometry using TANDEM accelerator in National Industrial Research Inst. of Nagoya

    Energy Technology Data Exchange (ETDEWEB)

    Mizota, Takeshi; Nakao, Setsuo; Niwa, Hiroaki; Saito, Kazuo [Particle Beam Sceince Laboratory, Multi-Function Material Science Department, National Industrial Research Inst. of Nagoya, Nagoya (Japan)

    2001-02-01

    Plasma Desorption Mass Spectrometry (PDMS) analysis was studied using TANDEM accelerator. The heavy ions of MeV range emit the secondary ions of atoms, molecules, polymers and clusters from the irradiated samples without destruction. The analysis system of PDMS designed and set-up using a mass spectrometer of Time of Flight and the TANDEM accelerator. The system performance was tested for C-60 fullerene on the surface of the samples using 11.2 MeV {sup 28}Si beams produced by the TANDEM accelerator of 1.7MV. The result shows that the hydrogen and hydrocarbons can be analyzed in the range of 1amu unit. The resolution (M/{delta}M) of the Mass Spectrometry system is confirmed to be about 1000 from the separation of the 720 and 721amu peaks, which is attributed to the C-60 fullerene including {sup 13}C atoms. (H. Katsuta)

  17. Development of a high performance liquid chromatography tandem mass spectrometry based analysis for the simultaneous quantification of various Alternaria toxins in wine, vegetable juices and fruit juices.

    Science.gov (United States)

    Zwickel, Theresa; Klaffke, Horst; Richards, Keith; Rychlik, Michael

    2016-07-15

    An analytical method based on high performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS) detection for the simultaneous quantification of 12 Alternaria toxins in wine, vegetable juices and fruit juices was developed. Excellent chromatographic performance was demonstrated for tenuazonic acid (TeA) in a multi-analyte method. This comprehensive study is also the first to report the determination of TeA, alternariol (AOH), alternariol monomethyl ether (AME), tentoxin (TEN) and altenuene (ALT), altertoxin I (ATX-I), altertoxin II (ATX-II), altenuisol (ATL), iso-altenuene (isoALT), altenuic acid III (AA-III) and the AAL toxins TB1 und TB2 in samples from the German market. Several types of HPLC columns were tested for the liquid chromatographic separation of the toxins of interest that widely differ in their polarities. The focus was on gaining suitable retention while avoiding derivatization steps especially for TeA and AA-III. Three atmospheric pressure ionization techniques used with liquid chromatography (electrospray, chemical and photo ionization) were tested to obtain the best selectivity and sensitivity. Samples were diluted with sodium hydrogen carbonate buffer and extracted on a diatomaceous earth solid phase extraction cartridge. Method validation was carried out by using tomato juice, citrus juice and white wine as blank matrices. Limits of detection ranged from 0.10 to 0.59μgL(-1) and limits of quantification ranged from 0.4-3.1μgL(-1) depending on the toxin and matrix. Recoveries were around 100±9% for all toxins except stemphyltoxin III (STTX-III) and altenusin (ALS) due to instability during sample clean up. Matrix-induced effects leading to ion suppression especially for ATX-I, ATX-II and AA-III were investigated. Relative standard deviations of repeatability (RSDr) and intermediate reproducibility (RSDR) were ≤9.3 and ≤17.1, respectively, for the toxins in different matrices at levels of 5 and 30μgL(-1). Finally, 103

  18. Interpretation of collision-induced fragmentation tandem mass spectra of posttranslationally modified peptides

    DEFF Research Database (Denmark)

    Bunkenborg, Jakob; Matthiesen, Rune

    2007-01-01

    Tandem collision-induced dissociation (CID) mass spectrometry (MS) provides a sensitive means of analyzing the amino acid sequence of peptides. Modern MS instrumentation is capable of rapidly generating many thousands of tandem mass spectra, and protein database search engines have been developed...... modified peptides, there is a need for manual validation of the data because search algorithms seldom have been optimized for the identification of modified peptides and because there are many pitfalls for the unwary. This chapter describes some of the issues that should be considered when interpreting...

  19. Authentication of Fish Products by Large-Scale Comparison of Tandem Mass Spectra

    DEFF Research Database (Denmark)

    Wulff, Tune; Nielsen, Michael Engelbrecht; Deelder, André M.;

    2013-01-01

    Authentication of food is a major concern worldwide to ensure that food products are correctly labeled in terms of which animals are actually processed for consumption. Normally authentication is based on species recognition by comparison of selected sequences of DNA or protein. We here present...... a new robust, proteome-wide tandem mass spectrometry method for species recognition and food product authentication. The method does not use or require any genome sequences or selection of tandem mass spectra but uses all acquired data. The experimental steps were performed in a simple, standardized...

  20. Study of electrospray ionization tandem mass spectrometry of the benzofuranone compounds

    Institute of Scientific and Technical Information of China (English)

    Zhan Qi Niu; Yu Min Sun; Feng Niu; Jian Han; Da Wei Chen

    2008-01-01

    A detailed analysis of benzofuranone compounds under multiple tandem mass spectrometry (ESI-MS(n)) conditions is reported. Element composition data of the fragment ions were obtained with the aid of comparison of the multiple tandem mass spectra of four compounds, and the structures of which are identical except for some substituted groups or epimers or ra-r/ww-isomers. Attempts have been made to provide rational pathways for the formation of the fragment ions from these protonated compounds. And the structure-fragmentation relationships will facilitate the characterization of the structures of other analogs.

  1. High explosives vapor detection by atmospheric sampling glow discharge ionization/tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    McLuckey, S.A.; Goeringer, D.E.; Asano, K.G. [Oak Ridge National Lab., TN (United States). Chemical and Analytical Sciences Div.

    1996-02-01

    The combination of atmospheric sampling glow discharge ionization with tandem mass spectrometry for the detection of traces of high explosives is described. Particular emphasis is placed on use of the quadrupole ion trap as the type of tandem mass spectrometer. Atmospheric sampling glow discharge provides a simple, rugged, and efficient means for anion formation while the quadrupole ion trap provides for efficient tandem mass spectrometry. Mass selective ion accumulation and non-specific ion activation methods can be used to overcome deleterious effects arising from ion/ion interactions. Such interactions constitute the major potential technical barrier to the use of the ion trap for real-time monitoring of targeted compounds in uncontrolled and highly variable matrices. Tailored waveforms can be used to effect both mass selective ion accumulation and ion activation. Concatenated tailored waveforms allow for both functions in a single experiment thereby providing the capability for monitoring several targeted species simultaneously. The combination of atmospheric sampling glow discharge ionization with a state-of-the-art analytical quadrupole ion trap is a highly sensitive and specific detector for traces of high explosives. The combination is also small and inexpensive relative to virtually any other form of tandem mass spectrometry. The science and technology underlying the glow discharge/ion trap combination is sufficiently mature to form the basis for an engineering effort to make the detector portable. 85 refs.

  2. Liquid Chromatography-Electrospray Quadrupole Linear Ion Trap Mass Spectrometric Method for Quantitation of Domperidone in Chinese Healthy Volunteers

    Institute of Scientific and Technical Information of China (English)

    WU Yi; CHU Yang; ZHANG Yun-hui; WU Dan; GU Jing-kai

    2007-01-01

    A rapid, sensitive, and accurate method based on LC/MS/MS was developed and validated for the determination of domperidone in human plasma. Domperidone and internal standard, tramadol, were extracted from plasma with diethyl ether-dichloromethane(60: 40, volume ratio) and separated by reversed-phase HPLC with methanol-water-ammonia solution(80: 20: 0.2, volume ratio) as the mobile phase. Detection was carried out via multiple-reaction monitoring(MRM) on a Q-trapTM LC/MS/MS system(Q-trapTM). The assay result was linear over a concentration range of 0.1-30 ng/mL with a limit of quantitation (LOQ) of 0.1 ng/mL. The inter- and intra-day precision levels were within 7.52% and 12. 9%, respectively, whereas the accuracy was within a range of 87. 3%-114%. This method has been successfully applied to evaluate the pharmacokinetics of domperidone in Chinese healthy volunteers given an oral dose of 10 mg.

  3. Metabolism of halogenated compounds in the white rot fungus Bjerkandera adusta studied by membrane inlet mass spectrometry and tandem mass spectrometry

    DEFF Research Database (Denmark)

    Beck, Hans Christian; Lauritsen, F.R.; Patrick, J.S.;

    1996-01-01

    Membrane inlet mass spectrometry has been used for the characterization of halogenated organic compounds produced by the fungus Bjerkandera adusta. Using this technique, electron impact-, chemical ionization-, electron capture negative chemical ionization-mass spectra and tandem mass spectra were...

  4. A multi-class bioanalytical methodology for the determination of bisphenol A diglycidyl ethers, p-hydroxybenzoic acid esters, benzophenone-type ultraviolet filters, triclosan, and triclocarban in human urine by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Asimakopoulos, Alexandros G; Wang, Lei; Thomaidis, Nikolaos S; Kannan, Kurunthachalam

    2014-01-10

    A liquid-liquid extraction (LLE; ethyl acetate) protocol, followed by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) methodology, was developed for the determination of 19 compounds, including bisphenol A diglycidyl ethers (BADGEs; industrial ethers), benzophenone-type UV filters (BP-UV filters; precursors and metabolites), p-hydroxybenzoic acid esters (parabens; preservatives), triclosan (TCS) and triclocarban (TCC) in human urine. Urine specimens were enzymatically deconjugated with β-glucuronidase (from Helix pomatia) and extracted by a LLE procedure for the measurement of total concentrations (i.e., free+conjugated forms) of target analytes. Absolute recoveries of BADGEs, BP-UV filters, parabens, TCS and TCC ranged 25-135%, 84-125%, 52-126%, 75-118% and 90-124%, respectively. Method precision (absolute values; N=5 replicate analyses at the fortification level of 10 ng, k=5 days) ranged from 5.8 (ethyl paraben) to 24.0% (TCS). The limits of quantification (LOQs) varied depending on the target compound and generally ranged from 0.2 to 2.0 ng/mL. The matrix effects ranged from +11 (2,3,4-trihydroxybenzophenone) to -86% (2,4-dihydroxybenzophenone). A total of 30 urine specimens collected from Athens, Greece, were analyzed for the 19 target compounds to demonstrate the applicability of the developed method. The concentrations of target chemicals in urine were presented on volume-, specific gravity (SG)-, and creatinine-normalization bases. MeP, EtP, PrP, OH-EtP, BADGE·2H2O, BP-1 and TCS were found frequently in urine at concentrations in the range of 2.7-436 ng/mL, <0.5-25.4 ng/mL, <0.5-575 ng/mL, <2-18.4 ng/mL, <0.5-13.8 ng/mL, <1-14.6 ng/mL and <0.5-95.3 ng/mL, respectively. PMID:24315674

  5. 液相色谱-串联质谱法检测贝类产品中腹泻性贝类毒素%Determination of Diarrhetic Shellfish Poisoning in Shellfishes by Liquid Chromatography with Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    母清林; 方杰; 万汉兴; 王晓华; 曹柳燕; 张庆红

    2011-01-01

    建立了贝类组织中2种腹泻性贝毒(Diamletic shellfish Poisobing,DSP)聚醚类毒素-大田软海绵酸(Okadaic acid,OA)和鳍藻毒素(Dinophysistoxin-1,DTX-1)的高效液相色谱-串联质谱分析方法.贝类样品经80%甲醇溶液提取,经正己烷脱脂和HLB固相萃取柱净化,采用Pursuit C18(150 mm×3.0 mm,3 μm,varian公司)色谱柱分离,以80%(V/V)甲醇水溶液为流动相等度洗脱,负离子扫描,在多反应监测(MRM)模式下进行定性与定量分析.在4~200 μg/L范围内线性关系良好,OA和DTX-1的最低定量限均为2 μg/kg.添加水平在2,25和50 μg/kg时的平均回收率大于80%,相对标准偏差小于11%(n=6).%A liquid chromatography-electrospray ionization triple-quadruple tandem.mass spectrometric method has been established for the determination of two kinds of diarrhetic shellfish poisoning including okadaic acid (QA) and dinophysistoxin-1 (DTX-1). After being extracted using methanol and water(80∶20, V/V ), the solution was extracted with n-hexane to remove lipid components and then cleaned-up by solid phase extraction (SPE) on an Oasis HLB cartridge. The analytes were eluted with methanol-water (80:20, V/V) on a Pursuit C18 column (150 mm×3.0 mm, 3 μm). The quantitative and confirmatory determination of OA and DTX-1 was performed by multiple reactions monitoring (MRM) mode. OA and DTX-1 were determined in the negative ion mode. The calibration curve was linear in the range of 4- 200 μg/L. The quantification limits of OA and DTX-1 were 2 μg/kg. The mean recoveries at spiked concentration of 2-100 μg/kg were more than 80% and the relative standard deviations were less than 11% (n=6).

  6. Combined Dynamic Arrays for Storing and Searching Semi-Ordered Tandem Mass Spectrometry Data

    Science.gov (United States)

    When performing bioinformatics analysis on tandem mass spectrometry data, there is a computational need to efficiently store and sort these semi-ordered data sets. To solve this problem, a new data structure based on dynamic arrays was designed and implemented in an algorithm that parses semi-order...

  7. Multiresidue analysis of pesticides in straw roughage by liquid chromatography - tandem mass spectrometry

    Science.gov (United States)

    A multiresidue analytical method using a modification of the “quick, easy, cheap, effective, rugged, and safe” (QuEChERS) sample preparation approach combined with liquid chromatography–tandem mass spectrometry (LC-MS/MS) analysis was established and validated for the rapid determination of 69 pesti...

  8. Quantification and validation of ertapenem using a liquid chromatography-tandem mass spectrometry method

    NARCIS (Netherlands)

    van Rijn, S.P.; Wessels, A.M.A.; Greijdanus, B.; Touw, D.J.; Alffenaar, J.W.C.

    2014-01-01

    Ertapenem, a carbapenem, relies on time-dependent killing. Therapeutic drug monitoring (TDM) should be considered, when ertapenem is used in specific populations, to achieve optimal bactericidal activity and optimize drug-dosing regimens. No validated liquid chromatography-tandem mass spectrometry (

  9. Differentiating samples and experimental protocols by direct comparison of tandem mass spectra

    NARCIS (Netherlands)

    Plas-Duivesteijn, Van Der Suzanne J.; Wulff, Tune; Klychnikov, Oleg; Keijzer, De Jeroen; Nessen, Merel A.

    2016-01-01

    Rationale Peptide tandem mass spectra can be analyzed by a number of means. They can be compared against predicted spectra of peptides derived from genome sequences, compared against previously acquired and identified spectra, or - sometimes - sequenced de novo. We recently introduced another met

  10. Analysis of the Aconitine Alkaloids in Chuanwu by Electrospray Ionization/Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    Ai Min SUN; Hui LI; Zhi Ming HUANG; P.P.H.BUT; Xue Qin DING

    2004-01-01

    An electrospray ionization / tandem mass spectrometric (ESI/MS/MS) method was developed for the simultaneous identification and analysis of three aconitine alkaloids [ mesacontine (MA), hypaconitine (HA), and aconitine (A)] as intact molecules at low nanogram level in Chinese traditional medicine Chuanwu decoction as well as in human whole blood extract without chromatographic separation.

  11. Fully automated screening of veterinary drugs in milk by turbulent flow chromatography and tandem mass spectrometry

    NARCIS (Netherlands)

    Stolker, A.A.M.; Peters, R.J.B.; Zuiderent, R.; DiBussolo, J.M.; Martins, C.P.B.

    2010-01-01

    There is an increasing interest in screening methods for quick and sensitive analysis of various classes of veterinary drugs with limited sample pre-treatment. Turbulent flow chromatography in combination with tandem mass spectrometry has been applied for the first time as an efficient screening met

  12. Mass spectrometric screening and identification of acidic metabolites in fulvic acid fractions of contaminated groundwater.

    Science.gov (United States)

    Jobelius, Carsten; Frimmel, Fritz H; Zwiener, Christian

    2014-05-01

    The anaerobic microbial degradation of aromatic and heterocyclic compounds is a prevalent process in contaminated groundwater systems. The introduction of functional groups into the contaminant molecules often results in aromatic and heterocyclic and succinic acids. These metabolites can be used as indicators for prevailing degradation processes. Therefore, there is a strong interest in developing analytical methods for screening and identification of these metabolites. In this study, neutral loss scans (NLS) by liquid chromatography-electrospray ionization/tandem mass spectrometry with losses of CO2 (NL ∆m/z = 44) and C2H4(CO2)2 (NL ∆m/z = 116) were applied for the first time successfully to screen selectively for acidic and succinic metabolites of aromatic and heterocyclic contaminants in two fulvic acid fractions from a contaminated site and a downstream region of a tar oil-polluted groundwater. Identification of these preselected signals was performed by high-resolution mass spectrometry with a liquid chromatography-electrospray ionization quadrupole time-of-flight mass spectrometry instrument. High-resolution mass and mass fragmentation data were then compared with a list of known metabolites from a literature search or matched with chemical databases supported with in silico fragmentation. Based on authentic analytical standards, several compounds from NLS were identified (e.g., 4-hydroxy-3-methylbenzoic acid, benzylsuccinic acid, naphthyl-2-methylsuccinic acid, 2-carboxyindane, and 2-carboxybenzothiophene) and tentatively identified (e.g., benzofuranmethylsuccinic acid and dihydrocarboxybenzothiophene) as aromatic, phenolic, heterocyclic, and succinic acids. The acidic metabolites were found exclusively in the contaminated region of the aquifer which indicates active biodegradation processes and no relevant occurrence of acidic metabolites in the downstream region.

  13. Quantitative analysis of phytosterols in edible oils using APCI liquid chromatography-tandem mass spectrometry

    OpenAIRE

    Mo, Shunyan; Dong, Linlin; Hurst, W Jeffrey; van Breemen, Richard B

    2013-01-01

    Previous methods for the quantitative analysis of phytosterols have usually used GC-MS and require elaborate sample preparation including chemical derivatization. Other common methods such as HPLC with absorbance detection do not provide information regarding the identity of the analytes. To address the need for an assay that utilizes mass selectivity while avoiding derivatization, a quantitative method based on LC-tandem mass spectrometry (LC-MS-MS) was developed and validated for the measur...

  14. Determination of Bedaquiline in Human Serum Using Liquid Chromatography-Tandem Mass Spectrometry

    OpenAIRE

    Alffenaar, Jan-Willem C; Bolhuis, Mathieu; van Hateren, Kai; Sturkenboom, Marieke; Akkerman, Onno; de Lange, Wiel; Greijdanus, Ben; van der Werf, Tjip; Touw, Daan

    2015-01-01

    Bedaquiline, a diarylquinoline for the treatment of multidrug-resistant tuberculosis (TB), relies on exposure-dependent killing. As data on drug exposure in specific populations are scarce, pharmacokinetic studies may be of interest. No simple and robust validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been reported to date. Therefore, a new method using a quadrupole mass spectrometer was developed for analysis of bedaquiline and N-monodesmethyl bedaquiline (M2) ...

  15. A collinear tandem time-of-flight mass spectrometer for infrared photodissociation spectroscopy of mass-selected ions

    Institute of Scientific and Technical Information of China (English)

    WANG GuanJun; CHI ChaoXian; XING XiaoPeng; DING ChuanFan; ZHOU MingFei

    2014-01-01

    An apparatus based on collinear tandem time-of-flight mass spectrometer has been designed for the measurement of infrared photodissociation spectroscopy of mass-selected ions in the gas phase.The ions from a pulsed laser vaporization supersonic ion source are skimmed and mass separated by a Wiley-McLaren time-of-flight mass spectrometer.The ion of interest is mass selected,decelerated and dissociated by a tunable IR laser.The fragment and parent ions are reaccelerated and mass analyzed by the second time-of-flight mass spectrometer.A simple new assembly integrated with mass gate,deceleration and reacceleration ion optics was designed,which allows us to measure the infrared spectra of mass selected ions with high sensitivity and easy timing synchronization.

  16. Atmospheric sampling glow discharge ionizataion and triple quadrupole tandem mass spectrometry for explosives vapor detection

    Energy Technology Data Exchange (ETDEWEB)

    McLuckey, S.A.; Goeringer, D.E.; Asano, K.G.; Hart, K.J.; Glish, G.L.; Grant, B.C.; Chambers, D.M.

    1993-08-01

    The detection and identification of trace vapors of hidden high explosives is an excellent example of a targeted analysis problem. It is desirable to push to ever lower levels the quantity or concentration of explosives material that provides an analytical signal, while at the same time discriminating against all other uninteresting material. The detection system must therefore combine high sensitivity with high specificity. This report describes the philosophy behind the use of atmospheric sampling glow discharge ionization, which is a sensitive, rugged, and convenient means for forming anions from explosives molecules, with tandem mass spectrometry, which provides unparalleled specificity in the identification of explosives-related ions. Forms of tandem mass spectrometry are compared and contrasted to provide a summary of the characteristics to be expected from an explosives detector employing mass spectrometry/mass spectrometry. The instrument developed for the FAA, an atmospheric sampling glow discharge/triple quadrupole mass spectrometer, is described in detail with particular emphasis on the ion source/spectrometer interface and on the capabilities of the spectrometer. Performance characteristics of the system are also described as they pertain to explosives of interest including a description of an automated procedure for the detection and identification of specific explosives. A comparison of various tandem mass spectrometers mated with atmospheric sampling glow discharge is then described and preliminary studies with a vapor preconcentration system provided by the FAA will be described.

  17. High Energy Collisions on Tandem Time-of-Flight Mass Spectrometers

    Science.gov (United States)

    Cotter, Robert J.

    2013-05-01

    Long before the introduction of matrix-assisted laser desorption/ionization (MALDI), electrospray ionization (ESI), Orbitraps, and any of the other tools that are now used ubiquitously for proteomics and metabolomics, the highest performance mass spectrometers were sector instruments, providing high resolution mass measurements by combining an electrostatic energy analyzer (E) with a high field magnet (B). In its heyday, the four sector mass spectrometer (or EBEB) was the crown jewel, providing the highest performance tandem mass spectrometry using single, high energy collisions to induce fragmentation. During a time in which quadrupole and tandem triple quadrupole instruments were also enjoying increased usage and popularity, there were, nonetheless, some clear advantages for sectors over their low collision energy counterparts. Time-of-flight (TOF) mass spectrometers are high voltage, high vacuum instruments that have much in common with sectors and have inspired the development of tandem instruments exploiting single high energy collisions. In this retrospective, we recount our own journey to produce high performance TOFs and tandem TOFs, describing the basic theory, problems, and the advantages for such instruments. An experiment testing impulse collision theory (ICT) underscores the similarities with sector mass spectrometers where this concept was first developed. Applications provide examples of more extensive fragmentation, side chain cleavages, and charge-remote fragmentation, also characteristic of high energy sector mass spectrometers. Moreover, the so-called curved-field reflectron has enabled the design of instruments that are simpler, collect and focus all of the ions, and may provide the future technology for the clinic, for tissue imaging, and the characterization of microorganisms.

  18. Development and validation of confirmatory method for analysis of nitrofuran metabolites in milk, honey, poultry meat and fish by liquid chromatography-mass spectrometry

    Directory of Open Access Journals (Sweden)

    Fatih Alkan

    2016-03-01

    Full Text Available In this study we have devoloped and validated a confirmatory analysis method for nitrofuran metabolites, which is in accordance with European Commission Decision 2002/657/EC requirements. Nitrofuran metabolites in honey, milk, poultry meat and fish samples were acidic hydrolised followed by derivatisation with nitrobenzaldehyde and liquid-liquid extracted with ethylacetate. The quantitative and confirmative determination of nitrofuran metbolites was performed by liquid chromatography/electrospray ionisation tandem mass spectrometry (LC/ESI-MS/MS in the positive ion mode. In-house method validation was performed and reported data of validation (specificity, linearity, recovery, CCα and CCβ. The advantage of this method is that it avoids the use of clean-up by Solid-Phase Extraction (SPE. Furthermore, low levels of nitrofuran metabolites are detectable and quantitatively confirmed at a rapid rate in all samples.

  19. Quantitation of protein post-translational modifications using isobaric tandem mass tags.

    Science.gov (United States)

    Liang, Hui-Chung; Lahert, Emma; Pike, Ian; Ward, Malcolm

    2015-01-01

    Post-translational modifications (PTMs) of proteins are known to modulate many cellular processes and their qualitative and quantitative evaluation is fundamental for understanding the mechanisms of biological events. Over the past decade, improvements in sample preparation techniques and enrichment strategies, the development of quantitative labeling strategies, the launch of a new generation of mass spectrometers and the creation of bioinformatics tools for the interrogation of ever larger datasets has established MS-based quantitative proteomics as a powerful workflow for global proteomics, PTM analysis and the elucidation of key biological mechanisms. With the advantage of their multiplexing capacity and the flexibility of an ever-growing family of different peptide-reactive groups, isobaric tandem mass tags facilitate quantitative proteomics and PTM experiments and enable higher sample throughput. In this review, we focus on the technical concept and utility of the isobaric tandem mass tag labeling approach to PTM analysis, including phosphorylation, glycosylation and S-nitrosylation. PMID:25697195

  20. Gas Chromatography/Atmospheric Pressure Chemical Ionization Tandem Mass Spectrometry for Fingerprinting the Macondo Oil Spill.

    Science.gov (United States)

    Lobodin, Vladislav V; Maksimova, Ekaterina V; Rodgers, Ryan P

    2016-07-01

    We report the first application of a new mass spectrometry technique (gas chromatography combined to atmospheric pressure chemical ionization tandem mass spectrometry, GC/APCI-MS/MS) for fingerprinting a crude oil and environmental samples from the largest accidental marine oil spill in history (the Macondo oil spill, the Gulf of Mexico, 2010). The fingerprinting of the oil spill is based on a trace analysis of petroleum biomarkers (steranes, diasteranes, and pentacyclic triterpanes) naturally occurring in crude oil. GC/APCI enables soft ionization of petroleum compounds that form abundant molecular ions without (or little) fragmentation. The ability to operate the instrument simultaneously in several tandem mass spectrometry (MS/MS) modes (e.g., full scan, product ion scan, reaction monitoring) significantly improves structural information content and sensitivity of analysis. For fingerprinting the oil spill, we constructed diagrams and conducted correlation studies that measure the similarity between environmental samples and enable us to differentiate the Macondo oil spill from other sources.

  1. A computational framework for heparan sulfate sequencing using high-resolution tandem mass spectra

    DEFF Research Database (Denmark)

    Hu, Han; Huang, Yu; Mao, Yang;

    2014-01-01

    activities. Its biological activities depend on the fine structures of its protein-binding domains, the determination of which remains a daunting task. Methods have advanced to the point that mass spectra with information-rich product ions may be produced on purified HS saccharides. However, the...... interpretation of these complex product ion patterns has emerged as the bottleneck to the dissemination of these HS sequencing methods. To solve this problem, we designed HS-SEQ, the first comprehensive algorithm for HS de novo sequencing using high-resolution tandem mass spectra. We tested HS-SEQ using negative...... electron transfer dissociation (NETD) tandem mass spectra generated from a set of pure synthetic saccharide standards with diverse sulfation patterns. The results showed that HS-SEQ rapidly and accurately determined the correct HS structures from large candidate pools....

  2. Peptide de novo sequencing of mixture tandem mass spectra

    DEFF Research Database (Denmark)

    Gorshkov, Vladimir; Hotta, Stéphanie Yuki Kolbeck; Braga, Thiago Verano;

    2016-01-01

    complementary b-, y-ions to each precursor peptide mass, which allowed the creation of virtual spectra containing sequence specific fragment ions of each co-isolated peptide. Deconvolution processing resulted in equally efficient identification rates but increased the absolute number of correctly sequenced...... peptides. The improvement was in the range of 20–35% additional peptide identifications for a HeLa lysate sample. Some correct sequences were identified only using unprocessed spectra; however, the number of these was lower than those where improvement was obtained by mass spectral deconvolution. Tight......The impact of mixture spectra deconvolution on the performance of four popular de novo sequencing programs was tested using artificially constructed mixture spectra as well as experimental proteomics data. Mixture fragmentation spectra are recognized as a limitation in proteomics because they...

  3. Evaluation of Physiological Amino Acids Profiling by Tandem Mass Spectrometry

    OpenAIRE

    Filee, Romain; Schoos, Roland; Boemer, François

    2013-01-01

    Background: Nowadays, the most conventional method to quantify physiological amino acids consists in ion exchange chromatography (IEC) followed by post-column ninhydrin derivatization and UV detection at two wavelengths. Unfortunately, the technique presents some drawbacks such as long run time, large sample volume, and specific costs associated to the maintenance of a dedicated instrument. Therefore, we aimed to switch towards a mass spectrometry approach.

  4. Analysis of Norditerpenoid Alkaloids Extracted from Aconitum sinomantanum Nakai by Electrospray Ionization Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Electrospray ionization mass spectrometry(ESI-MS) was applied simultaneously in determining norditerpenoid alkaloids from the roots of Aconitum sinomantanum Nakai (RAS) based on molecular mass information. The tandem mass spectra(ESI-MSn) provided the alkaloidal structural information, through which the existence of these alkaloids was further confirmed. Accordingly, six known norditerpenoid alkaloids were simultaneously determined on the basis of their ESI-MSn spectra. Furthermore, based on the diagnostic fragmentation pathways of alkaloidal MSn, a rapid method for direct detection and characterization of alkaloids from an ethanolic extract of RAS was described.

  5. Ion mobility tandem mass spectrometry enhances performance of bottom-up proteomics.

    Science.gov (United States)

    Helm, Dominic; Vissers, Johannes P C; Hughes, Christopher J; Hahne, Hannes; Ruprecht, Benjamin; Pachl, Fiona; Grzyb, Arkadiusz; Richardson, Keith; Wildgoose, Jason; Maier, Stefan K; Marx, Harald; Wilhelm, Mathias; Becher, Isabelle; Lemeer, Simone; Bantscheff, Marcus; Langridge, James I; Kuster, Bernhard

    2014-12-01

    One of the limiting factors in determining the sensitivity of tandem mass spectrometry using hybrid quadrupole orthogonal acceleration time-of-flight instruments is the duty cycle of the orthogonal ion injection system. As a consequence, only a fraction of the generated fragment ion beam is collected by the time-of-flight analyzer. Here we describe a method utilizing postfragmentation ion mobility spectrometry of peptide fragment ions in conjunction with mobility time synchronized orthogonal ion injection leading to a substantially improved duty cycle and a concomitant improvement in sensitivity of up to 10-fold for bottom-up proteomic experiments. This enabled the identification of 7500 human proteins within 1 day and 8600 phosphorylation sites within 5 h of LC-MS/MS time. The method also proved powerful for multiplexed quantification experiments using tandem mass tags exemplified by the chemoproteomic interaction analysis of histone deacetylases with Trichostatin A.

  6. Quantification of salsolinol enantiomers by stable isotope dilution liquid chromatography with tandem mass spectrometric detection

    OpenAIRE

    Cai, Min; Liu, Yi-Ming

    2008-01-01

    Salsolinol, 1-methyl-6,7-dihydroxy-2,3,4,5-tetrahydroisoquinoline (SAL), is a precursor of a Parkinsonian neurotoxin, N-methysalsolinol (N-methyl-SAL). Previous studies have shown that individual enantiomers of N-methyl-SAL possess distinct neurotoxicological properties. In this work, a chiral high-performance liquid chromatography (HPLC) method with electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the quantification of (R/S)-SAL enantiomers. Enantiose...

  7. An improved method for measuring metaldehyde in surface water using liquid chromatography tandem mass spectrometry

    OpenAIRE

    Schumacher, Melanie; Castle, Glenn; Gravell, Anthony; Mills, Graham; Fones, Gary Roland

    2016-01-01

    The molluscicide metaldehyde (2,4,6,8-tetramethyl-1,3,5,7-tetraoxocanemetacetaldehyde) is an emerging pollutant. It is frequently detected in surface waters, often above the European Community Drinking Water Directive limit of 0.1 μg/L for a single pesticide. Gas chromatography mass spectrometry (GC–MS) can be used to determine metaldehyde in environmental waters, but this method requires time consuming extraction techniques prior to instrumental analysis. Use of liquid chromatography-tandem ...

  8. A Review of Tandem Mass Spectrometry Characterization of Adenosine Diphosphate-Ribosylated Peptides

    OpenAIRE

    Hengel, Shawna M.; Goodlett, David R.

    2011-01-01

    The use of tandem mass spectrometry to identify and characterize sites of protein adenosine diphosphate (ADP) ribosylation will be reviewed. Specifically, we will focus on data acquisition schemes and fragmentation techniques that provide peptide sequence and modification site information. Also discussed are uses of synthetic standards to aid characterization, and an enzymatic method that converts ADP-ribosylated peptides into ribosyl mono phosphorylated peptides making identification amenabl...

  9. Direct Quantification of Cannabinoids and Cannabinoid Glucuronides in Whole Blood by Liquid Chromatography Tandem Mass Spectrometry

    OpenAIRE

    Schwope, David M.; Scheidweiler, Karl B.; Huestis, Marilyn A.

    2011-01-01

    The first method for quantifying cannabinoids and cannabinoid glucuronides in whole blood by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and validated. Solid-phase extraction followed protein precipitation with acetonitrile. HPLC separation was achieved in 16 min via gradient elution. Electrospray ionization was utilized for cannabinoid detection; both positive (Δ9-tetrahydrocannabinol [THC], cannabinol [CBN]) and negative (11-hydroxy-THC [11-OH-THC], 11-nor-9-carb...

  10. Detection of 10 sweeteners in various foods by liquid chromatography/tandem mass spectrometry

    OpenAIRE

    Chui-Shiang Chang; Tai Sheng Yeh

    2014-01-01

    The analytical method for sweeteners in various food matrixes is very important for food quality control and regulation enforcement. A simple and rapid method for the simultaneous determination of 10 sweeteners [acesulfame potassium (ACS-K), aspartame (ASP), cyclamate (CYC), dulcin (DUL), glycyrrhizic acid (GA), neotame (NEO), neohesperidin dihydrochalcone (NHDC), saccharin (SAC), sucralose (SCL), and stevioside (STV)] in various foods by liquid chromatography/tandem mass chromatography (LC–M...

  11. A review of clinical diagnostic applications of liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Shushan, Bori

    2010-01-01

    Liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS) technology is emerging as a complementary method to traditional methodology used for clinical applications. Enhanced specificity and high-throughput capabilities are providing significant benefits to clinical diagnostic laboratories conducting routine analyses. This technology is expected to expand rapidly as scientists focus on more complicated challenges that can be solved efficiently by adding LC/MS/MS to their arsenal of techniques. PMID:20949635

  12. Fast multi-blind modification search through tandem mass spectrometry.

    Science.gov (United States)

    Na, Seungjin; Bandeira, Nuno; Paek, Eunok

    2012-04-01

    With great biological interest in post-translational modifications (PTMs), various approaches have been introduced to identify PTMs using MS/MS. Recent developments for PTM identification have focused on an unrestrictive approach that searches MS/MS spectra for all known and possibly even unknown types of PTMs at once. However, the resulting expanded search space requires much longer search time and also increases the number of false positives (incorrect identifications) and false negatives (missed true identifications), thus creating a bottleneck in high throughput analysis. Here we introduce MODa, a novel "multi-blind" spectral alignment algorithm that allows for fast unrestrictive PTM searches with no limitation on the number of modifications per peptide while featuring over an order of magnitude speedup in relation to existing approaches. We demonstrate the sensitivity of MODa on human shotgun proteomics data where it reveals multiple mutations, a wide range of modifications (including glycosylation), and evidence for several putative novel modifications. Based on the reported findings, we argue that the efficiency and sensitivity of MODa make it the first unrestrictive search tool with the potential to fully replace conventional restrictive identification of proteomics mass spectrometry data. PMID:22186716

  13. Fast multi-blind modification search through tandem mass spectrometry.

    Science.gov (United States)

    Na, Seungjin; Bandeira, Nuno; Paek, Eunok

    2012-04-01

    With great biological interest in post-translational modifications (PTMs), various approaches have been introduced to identify PTMs using MS/MS. Recent developments for PTM identification have focused on an unrestrictive approach that searches MS/MS spectra for all known and possibly even unknown types of PTMs at once. However, the resulting expanded search space requires much longer search time and also increases the number of false positives (incorrect identifications) and false negatives (missed true identifications), thus creating a bottleneck in high throughput analysis. Here we introduce MODa, a novel "multi-blind" spectral alignment algorithm that allows for fast unrestrictive PTM searches with no limitation on the number of modifications per peptide while featuring over an order of magnitude speedup in relation to existing approaches. We demonstrate the sensitivity of MODa on human shotgun proteomics data where it reveals multiple mutations, a wide range of modifications (including glycosylation), and evidence for several putative novel modifications. Based on the reported findings, we argue that the efficiency and sensitivity of MODa make it the first unrestrictive search tool with the potential to fully replace conventional restrictive identification of proteomics mass spectrometry data.

  14. Correction: Synergism between genome sequencing, tandem mass spectrometry and bio-inspired synthesis reveals insights into nocardioazine B biogenesis.

    Science.gov (United States)

    Alqahtani, Norah; Porwal, Suheel K; James, Elle D; Bis, Dana M; Karty, Jonathan A; Lane, Amy L; Viswanathan, Rajesh

    2015-09-21

    Correction for 'Synergism between genome sequencing, tandem mass spectrometry and bio-inspired synthesis reveals insights into nocardioazine B biogenesis' by Norah Alqahtani et al., Org. Biomol. Chem., 2015, 13, 7177-7192.

  15. Ligand binding mode to duplex and triplex DNA assessed by combining electrospray tandem mass spectrometry and molecular modeling

    OpenAIRE

    Rosu, Frédéric; Nguyen, Chi-Hung; De Pauw, Edwin; Gabelica, Valérie

    2007-01-01

    In this paper, we report the analysis of seven benzopyridoindole and benzopyridoquinoxaline drugs binding to different duplex DNA and triple helical DNA, using an approach combining electrospray ionization mass spectrometry (ESI-MS), tandem mass spectrometry (MS/MS), and molecular modeling. The ligands were ranked according to the collision energy (CE(50)) necessary to dissociate 50% of the complex with the duplex or the triplex in tandem MS. To determine the probable ligand binding site and ...

  16. Development and validation of a liquid chromatography-tandem mass spectrometry assay for the simultaneous quantitation of microcystin-RR and its metabolites in fish liver.

    Science.gov (United States)

    Wu, Laiyan; Xie, Ping; Chen, Jun; Zhang, Dawen; Liang, Gaodao

    2010-02-26

    A novel method for identification and quantification of microcystin-RR (MC-RR) and its metabolites (MC-RR-GSH and MC-RR-Cys) in the fish liver was developed and validated. These analytes were simultaneously extracted from fish liver using water containing EDTA with 5% acetic acid, followed by a mixed-mode cation-exchange SPE (Oasis MCX) and subsequently determined by liquid chromatography-electrospray ionization ion trap mass spectrometry (LC-ESI-ITMS). Extraction parameters including volume and pH of eluting solvents, were optimized. Best recoveries were obtained by using 10 mL of 15% ammonia solution in methanol. The mean recoveries at three concentrations (0.2, 1.0, and 5.0 microg g(-1) dry weight [DW]) for MC-RR, MC-RR-GSH and MC-RR-Cys were 93.6-99%, 68.1-73.6% and 90.0-95.2%, respectively. Method detection limit (MDL) were 4, 7 and 5 ng g(-1) DW for MC-RR, MC-RR-GSH and MC-RR-Cys, respectively. Limits of quantification (LOQs) for MC-RR, MC-RR-GSH and MC-RR-Cys were calculated to be 10, 18 and 13 ng g(-1) DW, respectively. Finally, this method was successfully applied to the identification and quantification of MC-RR, MC-RR-GSH and MC-RR-Cys in the liver of bighead carp with acute exposure of MCs. PMID:20060532

  17. Characteristic Fragmentation Behavior of Steroidal Phosphoramidate Conjugates in Electrospray Ionization Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    JI, San-Hao; JU, Yong; XIAO, Qiang; ZHAO, Yu-Fen

    2006-01-01

    Novel steroidal phosphoramidate conjugates of 3'-azido-2',3'-dideoxythymidine (AZT) and amino acid esters were synthesized and determined by positive and negative ion electrospray ionization mass spectrometry. The MS fragmentation behaviors of the steroidal phosphoramidate conjugates have been investigated in conjunction with tandem mass spectrometry of ESI-MS/MS. There were three characteristic fragment ions in the positive ion ESI mass spectra, which were the Na adduct ions with loss of steroidal moiety, amino acid ester moiety from pseudo molecular ion (M+Na)+, and the phosphoamino acid methyl ester Na adduct ion by a-cleavage of the phosphoramidate respectively. The main fragment ions in negative ion ESI mass spectra were the ion (M-HN3)-, the ion (M - AZT - H)- , and the ion (M-steroidal moiety-H)- besides the pseudo molecular ion (M-H)-. The fragmentation patterns did not depend on the attached amino acid ester moiety.

  18. Exploiting the multiplexing capabilities of tandem mass tags for high-throughput estimation of cellular protein abundances by mass spectrometry.

    Science.gov (United States)

    Ahrné, Erik; Martinez-Segura, Amalia; Syed, Afzal Pasha; Vina-Vilaseca, Arnau; Gruber, Andreas J; Marguerat, Samuel; Schmidt, Alexander

    2015-09-01

    The generation of dynamic models of biological processes critically depends on the determination of precise cellular concentrations of biomolecules. Measurements of system-wide absolute protein levels are particularly valuable information in systems biology. Recently, mass spectrometry based proteomics approaches have been developed to estimate protein concentrations on a proteome-wide scale. However, for very complex proteomes, fractionation steps are required, increasing samples number and instrument analysis time. As a result, the number of full proteomes that can be routinely analyzed is limited. Here we combined absolute quantification strategies with the multiplexing capabilities of isobaric tandem mass tags to determine cellular protein abundances in a high throughput and proteome-wide scale even for highly complex biological systems, such as a whole human cell line. We generated two independent data sets to demonstrate the power of the approach regarding sample throughput, dynamic range, quantitative precision and accuracy as well as proteome coverage in comparison to existing mass spectrometry based strategies.

  19. Differentiating samples and experimental protocols by direct comparison of tandem mass spectra

    DEFF Research Database (Denmark)

    van der Plas-Duivesteijn, Suzanne J.; Wulff, Tune; Klychnikov, Oleg;

    2016-01-01

    aiming for quality control of two traceable protein reference standards (troponin) used in clinical chemistry assays, by analysing the effect of storage conditions. The results illustrate a broad applicability of the metric based on shared tandem mass spectra between LC/MS/MS datasets for analysing......, serendipitous uses. We used the existing compareMS2 algorithm without modification on a diverse set of experiments. First we conducted a small phylogenetic study, using (mammalian) bone samples to study old material, and human pathogens aiming to distinguish clinically important strains. Although...

  20. A new tandem mass spectrometer for photofragment spectroscopy of cold, gas-phase molecular ions

    International Nuclear Information System (INIS)

    We present here the design of a new tandem mass spectrometer that combines an electrospray ion source with a cryogenically cooled ion trap for spectroscopic studies of cold, gas-phase ions. The ability to generate large ions in the gas phase without fragmentation, cool them to ∼10 K in an ion trap, and perform photofragment spectroscopy opens up new possibilities for spectroscopic characterization of large biomolecular ions. The incorporation of an ion funnel, together with a number of small enhancements, significantly improves the sensitivity, signal stability, and ease of use compared with the previous instrument built in our laboratory.

  1. Identification of compounds in wine by HPLC-tandem mass spectrometry.

    Science.gov (United States)

    Bevilacqua, Lucio; Buiarelli, Francesca; Coccioli, Franco; Jasionowska, Renata

    2004-01-01

    In this work several compounds were detected in wines by HPLC-tandem mass spectrometry. In particular cinnamic and benzoic acids, tyrosol, apigenin-7-glucoside and luteolin-7-glucoside were identified and quantified in Italian wines. Red wines show bigger amount of cinnamic and benzoic acids than white wines. tyrosol is in bigger amount with respect to two flavones: luteolin-7-glucoside and apigenin-7-glucoside. These last two flavones are only in some wine, but it can be important to detect the presence of different substances in small amount to be able to characterize a wine. PMID:15506618

  2. Gas Chromatography/Atmospheric Pressure Chemical Ionization Tandem Mass Spectrometry for Fingerprinting the Macondo Oil Spill.

    Science.gov (United States)

    Lobodin, Vladislav V; Maksimova, Ekaterina V; Rodgers, Ryan P

    2016-07-01

    We report the first application of a new mass spectrometry technique (gas chromatography combined to atmospheric pressure chemical ionization tandem mass spectrometry, GC/APCI-MS/MS) for fingerprinting a crude oil and environmental samples from the largest accidental marine oil spill in history (the Macondo oil spill, the Gulf of Mexico, 2010). The fingerprinting of the oil spill is based on a trace analysis of petroleum biomarkers (steranes, diasteranes, and pentacyclic triterpanes) naturally occurring in crude oil. GC/APCI enables soft ionization of petroleum compounds that form abundant molecular ions without (or little) fragmentation. The ability to operate the instrument simultaneously in several tandem mass spectrometry (MS/MS) modes (e.g., full scan, product ion scan, reaction monitoring) significantly improves structural information content and sensitivity of analysis. For fingerprinting the oil spill, we constructed diagrams and conducted correlation studies that measure the similarity between environmental samples and enable us to differentiate the Macondo oil spill from other sources. PMID:27281271

  3. Scandium analysis in silicon-containing minerals by inductively coupled plasma tandem mass spectrometry

    Science.gov (United States)

    Whitty-Léveillé, Laurence; Drouin, Elisabeth; Constantin, Marc; Bazin, Claude; Larivière, Dominic

    2016-04-01

    This article reports on the development of a new method for the accurate and precise determination of the amount of scandium, Sc, in silicon-containing minerals, based on the use of tandem quadrupole inductively coupled plasma mass spectrometry (ICP-MS/MS). The tandem quadrupole instrument enables new mass filtering configurations, which can reduce polyatomic interferences during the determination of Sc in mineral matrices. He and O2 were used and compared as collision and reaction gases for the removal of interferences at m/z 45 and 61. Using helium gas was ineffective to overcome all of the spectral interferences observed at m/z 45 and particularly for Si-based interferences. However, conversion of Sc+ ions into ScO+ ions (after bombardment with O2 in the octopole reaction system coupled with the use of the instrument in MS/MS mass-shift mode) provided interference-free conditions and sufficiently low limits of detection, down to 3 ng L- 1, to accurately detect Sc. The accuracy of the proposed methodology was assessed by analyzing five different reference materials (BX-N, OKA-2, NIM-L, SY-3 and GH).

  4. Expedient preparative isolation and tandem mass spectrometric characterization of C-seco triterpenoids from Neem oil.

    Science.gov (United States)

    Haldar, Saikat; Mulani, Fayaj A; Aarthy, Thiagarayaselvam; Dandekar, Devdutta S; Thulasiram, Hirekodathakallu V

    2014-10-31

    C-seco triterpenoids are widely bioactive class of natural products with high structural complexity and diversity. The preparative isolation of these molecules with high purity is greatly desirable, although restricted due to the complexity of natural extracts. In this article we have demonstrated a Medium Pressure Liquid Chromatography (MPLC) based protocol for the isolation of eight major C-seco triterpenoids of salannin skeleton from Neem (Azadirachta indica) oil. Successive application of normal phase pre-packed silica-gel columns for the fractionation followed by reverse phase in automated MPLC system expedited the process and furnished highly pure metabolites. Furthermore, eight isolated triterpenoids along with five semi-synthesized derivatives were characterized using ultra performance liquid chromatography-electrospray ionization-quadrupole/orbitrap-MS/MS spectrometry as a rapid and sensitive identification technique. The structure-fragment relationships were established on the basis of plausible mechanistic pathway for the generation of daughter ions. The MS/MS spectral information of the triterpenoids was further utilized for the identification of studied molecules in the complex extract of stem and bark tissues from Neem. PMID:25267707

  5. Expedient preparative isolation and tandem mass spectrometric characterization of C-seco triterpenoids from Neem oil.

    Science.gov (United States)

    Haldar, Saikat; Mulani, Fayaj A; Aarthy, Thiagarayaselvam; Dandekar, Devdutta S; Thulasiram, Hirekodathakallu V

    2014-10-31

    C-seco triterpenoids are widely bioactive class of natural products with high structural complexity and diversity. The preparative isolation of these molecules with high purity is greatly desirable, although restricted due to the complexity of natural extracts. In this article we have demonstrated a Medium Pressure Liquid Chromatography (MPLC) based protocol for the isolation of eight major C-seco triterpenoids of salannin skeleton from Neem (Azadirachta indica) oil. Successive application of normal phase pre-packed silica-gel columns for the fractionation followed by reverse phase in automated MPLC system expedited the process and furnished highly pure metabolites. Furthermore, eight isolated triterpenoids along with five semi-synthesized derivatives were characterized using ultra performance liquid chromatography-electrospray ionization-quadrupole/orbitrap-MS/MS spectrometry as a rapid and sensitive identification technique. The structure-fragment relationships were established on the basis of plausible mechanistic pathway for the generation of daughter ions. The MS/MS spectral information of the triterpenoids was further utilized for the identification of studied molecules in the complex extract of stem and bark tissues from Neem.

  6. Atmospheric pressure ionization-tandem mass spectrometry of the phenicol drug family.

    Science.gov (United States)

    Alechaga, Élida; Moyano, Encarnación; Galceran, M Teresa

    2013-11-01

    In this work, the mass spectrometry behaviour of the veterinary drug family of phenicols, including chloramphenicol (CAP) and its related compounds thiamphenicol (TAP), florfenicol (FF) and FF amine (FFA), was studied. Several atmospheric pressure ionization sources, electrospray (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization were compared. In all atmospheric pressure ionization sources, CAP, TAP and FF were ionized in both positive and negative modes; while for the metabolite FFA, only positive ionization was possible. In general, in positive mode, [M + H](+) dominated the mass spectrum for FFA, while the other compounds, CAP, TAP and FF, with lower proton affinity showed intense adducts with species present in the mobile phase. In negative mode, ESI and atmospheric pressure photoionization showed the deprotonated molecule [M-H](-), while atmospheric pressure chemical ionization provided the radical molecular ion by electron capture. All these ions were characterized by tandem mass spectrometry using the combined information obtained by multistage mass spectrometry and high-resolution mass spectrometry in a quadrupole-Orbitrap instrument. In general, the fragmentation occurred via cyclization and losses or fragmentation of the N-(alkyl)acetamide group, and common fragmentation pathways were established for this family of compounds. A new chemical structure for the product ion at m/z 257 for CAP, on the basis of the MS(3) and MS(4) spectra is proposed. Thermally assisted ESI and selected reaction monitoring are proposed for the determination of these compounds by ultra high-performance liquid chromatography coupled to tandem mass spectrometry, achieving instrumental detection limits down to 0.1 pg.

  7. Design and performance of an instrument for electron impact tandem mass spectrometry and action spectroscopy of mass/charge selected macromolecular ions stored in RF ion trap*

    Science.gov (United States)

    Ranković, Milos Lj.; Giuliani, Alexandre; Milosavljević, Aleksandar R.

    2016-06-01

    A new apparatus was designed, coupling an electron gun with a linear quadrupole ion trap mass spectrometer, to perform m/ z (mass over charge) selected ion activation by electron impact for tandem mass spectrometry and action spectroscopy. We present in detail electron tracing simulations of a 300 eV electron beam inside the ion trap, design of the mechanical parts, electron optics and electronic circuits used in the experiment. We also report examples of electron impact activation tandem mass spectra for Ubiquitin protein, Substance P and Melittin peptides, at incident electron energies in the range from 280 eV to 300 eV.

  8. Liquid chromatography/tandem mass spectrometry assay for the quantification of troxerutin in human plasma.

    Science.gov (United States)

    Liu, Fei; Xu, Yu; Rui, Lei; Gao, Shu; Dong, Haijun; Guo, Qingxiang

    2006-01-01

    A simple, rapid, sensitive and specific liquid chromatography/tandem mass spectrometry method was developed and validated to quantify troxerutin in human plasma. The analyte and rutin, used as the internal standard, were analyzed on a Phenomenex Synergi Fusion RP column interfaced with a triple-quadrupole tandem mass spectrometer using positive electrospray ionization. Acetonitrile/water (20:80 v/v) was used as the isocratic mobile phase, with 0.1% formic acid in water. A simple sample preparation method of protein precipitation with perchloric acid was employed. The assay was linear over the concentration range 31.25-4000 pg/mL. Correlation coefficients generated by linear regression with a 1/x(2) weighting factor ranged from 0.9991 to 0.9996. The intra- and inter-day precision over the entire concentration range were less than 12.28%. The method was successfully applied to a pharmacokinetic study after oral administration of a 300 mg troxerutin drop pill to 18 healthy volunteers.

  9. Analysis of alcohols, as dimethylglycine esters, by electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Johnson, D W

    2001-03-01

    Dimethylglycine (DMG) esters are new derivatives for the rapid, sensitive and selective analysis of primary and secondary alcohols, in complex mixtures, by electrospray ionization tandem mass spectrometry (ESI-MS/MS). Their development was inspired by the use of the complementary dimethylaminoethyl esters for the trace, rapid analysis of fatty acids. DMG esters are simply prepared by heating a dichloromethane solution of the imidazolide of dimethylglycine, containing triethylamine, and an alcohol. DMG esters of long-chain fatty alcohols, isoprenoidal alcohols and hydroxy-acids are analysed by electrospray ionization tandem mass spectrometry with a precursor ion of m/z 104 scan. Diols, glyceryl esters, glyceryl ethers and some sterols are analysed by a neutral loss of 103 Da scan. Trimethylglycine (TMG) ester iodides, prepared by alkylation of DMG esters with methyl iodide, are more sensitive derivatives for molecules containing secondary alcohol groups, such as cholesterol and gibberellic acid. They are analysed by a precursor ion of m/z 118 scan. DMG or TMG derivatives were shown to be at least comparable and sometimes an order of magnitude more sensitive than N-methylpyridyl ether derivatives for ESI-MS/MS analysis of the different classes of alcohols. Applications of these derivatives for the diagnosis of inherited disorders and the analysis of natural products are presented. PMID:11312519

  10. Quantitative analysis of tivantinib in rat plasma using ultra performance liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Bai, Yan-Li; Yuan, Hong-Chang; Zhang, Dong-Tao; Liu, Yuan; Zhang, Yin

    2016-07-15

    In this work, a simple, sensitive and fast ultra performance liquid chromatography with tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the quantitative determination of tivantinib in rat plasma. Plasma samples were processed with a protein precipitation. The separation was achieved by an Acquity UPLC BEH C18 (2.1mm×50mm, 1.7μm) column with a gradient mobile phase consisting of 0.1% formic acid in water and acetonitrile. Detection was carried out using positive-ion electrospray tandem mass spectrometry via multiple reaction monitoring (MRM). The validated method had an excellent linearity in the range of 1.0-100ng/mL (r(2)>0.9967) with a lower limit of quantification (1.0ng/mL). The extraction recovery was in the range of 79.4-84.2% for tivantinib and 80.3% for carbamazepine (internal standard, IS). The intra- and inter-day precision was below 8.9% and accuracy was from -7.2% to 9.5%. No notable matrix effect and astaticism was observed for tivantinib. The method has been successfully applied to a pharmacokinetic study of tivantinib in rats for the first time, which provides the basis for the further development and application of tivantinib. PMID:27179187

  11. Determination of bromate in drinking water by ultraperformance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Alsohaimi, Ibrahim Hotan; Alothman, Zeid Abdullah; Khan, Mohammad Rizwan; Abdalla, Mohammad Abulhassan; Busquets, Rosa; Alomary, Ahmad Khodran

    2012-10-01

    Bromate is a byproduct formed as a result of disinfection of bromide-containing source water with ozone or hypochlorite. The International Agency for Research on Cancer has recognized bromate as a possible human carcinogen, thus it is essential to determine in drinking water. Present work highlights a development of sensitive and fast analytical method for bromate determination in drinking water by using ultraperformance liquid chromatography-tandem mass spectrometry. The quality parameters of the developed method were established, obtaining very low limit of detection (0.01 ng/mL), repeatability and reproducibility have been found to be less than 3% in terms of relative standard deviation when analyzing a bromate standard at 0.05 μg/mL with 0.4 min analysis time. Developed method was applied for the analysis of metropolitan and bottled water from Saudi Arabia; 22 samples have been analyzed. Bromate was detected in the metropolitan water samples (from desalinization source) at concentrations ranging between 3.43 and 75.04 ng/mL and in the bottled water samples at concentrations ranging between 2.07 and 21.90 ng/mL. Moreover, in comparison to established analytical methods such as liquid chromatography-tandem mass spectrometry, the proposed method was found to be very sensitive, selective and rapid for the routine analysis of bromate at low level in drinking water.

  12. Determination of biogenic amines in beer and wine by capillary electrophoresis-tandem mass spectrometry.

    Science.gov (United States)

    Daniel, Daniela; Dos Santos, Vagner Bezerra; Vidal, Denis Tadeu Rajh; do Lago, Claudimir Lucio

    2015-10-16

    A capillary electrophoresis-tandem mass spectrometry (CE-MS/MS) method for the simultaneous assessment of nine biogenic amines (spermine, spermidine, putrescine, cadaverine, histamine, phenylethylamine, tryptamine, tyramine, and urocanic acid) in commercial samples of beer and wine is introduced. The samples were submitted to a simple clean-up step with poly(vinylpolypyrrolidone) followed by filtration. Electrophoretic separation in a polyvinyl alcohol (PVA)-coated capillary using 0.5 mol L(-1) acetic acid (pH 2.5) as background electrolyte and detection by electrospray-tandem mass spectrometry was employed. The range of the correlation coefficients of the calibration curves of the analyzed compounds was 0.996-0.999, and the limits of detection and limits of quantification were in the range of 1-2 μg L(-1) and 3-8 μg L(-1), respectively. The recovery values for samples spiked at three concentration levels (0.2, 0.5, and 1.0 mg L(-1)) ranged from 87 to 113% with standard deviation not greater than 5.8%. The use of a PVA-coated silica capillary allows suppressing the electroosmotic flow and, consequently, increasing of the separation efficiency. The method was successfully used to determine biogenic amines in commercial samples of beer and wine. PMID:26362807

  13. Determination of biogenic amines in beer and wine by capillary electrophoresis-tandem mass spectrometry.

    Science.gov (United States)

    Daniel, Daniela; Dos Santos, Vagner Bezerra; Vidal, Denis Tadeu Rajh; do Lago, Claudimir Lucio

    2015-10-16

    A capillary electrophoresis-tandem mass spectrometry (CE-MS/MS) method for the simultaneous assessment of nine biogenic amines (spermine, spermidine, putrescine, cadaverine, histamine, phenylethylamine, tryptamine, tyramine, and urocanic acid) in commercial samples of beer and wine is introduced. The samples were submitted to a simple clean-up step with poly(vinylpolypyrrolidone) followed by filtration. Electrophoretic separation in a polyvinyl alcohol (PVA)-coated capillary using 0.5 mol L(-1) acetic acid (pH 2.5) as background electrolyte and detection by electrospray-tandem mass spectrometry was employed. The range of the correlation coefficients of the calibration curves of the analyzed compounds was 0.996-0.999, and the limits of detection and limits of quantification were in the range of 1-2 μg L(-1) and 3-8 μg L(-1), respectively. The recovery values for samples spiked at three concentration levels (0.2, 0.5, and 1.0 mg L(-1)) ranged from 87 to 113% with standard deviation not greater than 5.8%. The use of a PVA-coated silica capillary allows suppressing the electroosmotic flow and, consequently, increasing of the separation efficiency. The method was successfully used to determine biogenic amines in commercial samples of beer and wine.

  14. Determination of parabens in serum by liquid chromatography-tandem mass spectrometry: Correlation with lipstick use.

    Science.gov (United States)

    Tahan, Gabriella Padovani; Santos, Nayara de Kássia Souza; Albuquerque, Ana Carolina; Martins, Isarita

    2016-08-01

    Parabens are the most widely used preservative and are considered to be relatively safe compounds. However, studies have demonstrated that they may have estrogenic activity, and there is ongoing debate regarding the safety and potential cancer risk of using products containing these compounds. In the present work, liquid chromatography-tandem mass spectrometry was applied to determine methylparaben and propylparaben concentrations in serum, and the results were correlated with lipstick application. Samples were analyzed using liquid-liquid extraction, followed by liquid chromatography-tandem mass spectrometry. The validation results demonstrated the linearity of the method over a range of 1-20 ng/mL, in addition to the method's precision and accuracy. A statistically significant difference was demonstrated between serum parabens in women who used lipstick containing these substances compared with those not using this cosmetic (p = 0.0005 and 0.0016, respectively), and a strong association was observed between serum parabens and lipstick use (Spearman correlation = 0.7202). PMID:27154569

  15. Investigation of the Interaction Between Sodium(meta) Arsenite and Catechin via ESI Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    CUI Sheng-yun; WEN Jin-feng; KIM Seung-jin; LEE Yong-ill

    2007-01-01

    Catechin, one of the main components of green tea, is considered to have the remedy effect of arsenic poison,although the chemical mechanism is not well known. In this study, sodium(meta) selenite, which is used as herbisolution to investigate the interaction between toxic inorganic arsenic compound and catechin via ESI tandem mass spectrometry. The interaction products of mono-methylated arsenic with catechin in the presence of methanol were identified in the negative mode. Collission induced dissociation(CID) mass spectrometric measurements indicate that monomethylated arsenic was "alkylated" strongly by conjugation at the sites of C2' and C5' in the phenyl ring B of the catechin. The interaction mechanism between sodium(meta) arsenite and catechin was proposed. The results provide useful information to understand the chemical pathway of the detoxification of the arsenic toxicity by catechin.

  16. Recent advances of liquid chromatography-(tandem) mass spectrometry in clinical and forensic toxicology - An update.

    Science.gov (United States)

    Remane, Daniela; Wissenbach, Dirk K; Peters, Frank T

    2016-09-01

    Liquid chromatography (LC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) is a well-established and widely used technique in clinical and forensic toxicology as well as doping control especially for quantitative analysis. In recent years, many applications for so-called multi-target screening and/or quantification of drugs, poisons, and or their metabolites in biological matrices have been developed. Such methods have proven particularly useful for analysis of so-called new psychoactive substances that have appeared on recreational drug markets throughout the world. Moreover, the evolvement of high resolution MS techniques and the development of data-independent detection modes have opened new possibilities for applications of LC-(MS/MS) in systematic toxicological screening analysis in the so called general unknown setting. The present paper will provide an overview and discuss these recent developments focusing on the literature published after 2010.

  17. Functional group composition of ambient and source organic aerosols determined by tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    J. Dron

    2010-04-01

    Full Text Available The functional group composition of various organic aerosols (OA is being investigated using a recently developed analytical approach based on atmospheric pressure chemical ionisation-tandem mass spectrometry (APCI-MS/MS. The determinations of the three functional groups' contents are performed quantitatively by neutral loss (carboxylic and carbonyl groups and precursor ion (nitro groups scanning modes of a tandem mass spectrometer. Major organic aerosol sources are studied: vehicular emission and wood combustion for primary aerosol sources; and a secondary organic aerosol (SOA produced through photo-oxidation of o-xylene. The results reveal significant differences in the functional group contents of these source aerosols. The laboratory generated SOA is dominated by carbonyls while carboxylics are preponderate in the wood combustion particles. On the other hand, vehicular emissions are characterised by a strong nitro content. The total amount of the three functional groups accounted for 1.7% (vehicular to 13.5% (o-xylene photo-oxidation of the organic carbon. The diagnostic functional group ratios are then used to tentatively differentiate sources of particles collected in an urban background environment located in an Alpine valley (Chamonix, France during a strong winter pollution event. The three functional groups under study account for a total functionalisation rate of 2.2 to 3.8% of the organic carbon in this ambient aerosol, which is also dominated by carboxylic moieties. In this particular case study of a deep alpine valley during winter, we show that the nitro- and carbonyl-to-carboxylic diagnostic ratios can be a useful tool to distinguish the sources. In these conditions, the total OA concentrations are highly dominated by wood combustion OA. This result is confirmed by an organic markers source apportionment approach which assesses a wood burning organic carbon contribution of about 60%. Finally, examples of functional group mass

  18. Determination of usnic acid in lichen toxic to elk by liquid chromatography with ultraviolet and tandem mass spectrometry detection.

    Science.gov (United States)

    Roach, John A G; Musser, Steven M; Morehouse, Kim; Woo, Jason Y J

    2006-04-01

    Usnic acid is unambiguously confirmed by tandem mass spectrometry (MS/MS) in tumbleweed shield lichen, Xanthoparmelia chlorochroa. The lichen contains 2% usnic acid by liquid chromatography with UV quantification at 282 nm. The UV linear range for usnic acid quantification is from its 4 ng limit of detection to 2 microg injected. UV signal saturation is recognized by distortion of the usnic acid UV spectrum. Positive ion electrospray-tandem mass spectrometry offers no similar means to recognize quantification data recorded above the linear range of electrospray. Electrospray ionization capacity and matrix effects limit the reliability of tandem mass spectrometry quantification. The combination of UV quantification and MS confirmation provides a reliable analytical method for measuring usnic acid levels in plant material. PMID:16569032

  19. Diagnosing lysosomal storage diseases in a Brazilian non-newborn population by tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Guilherme Dotto Brand

    2013-11-01

    Full Text Available OBJECTIVES: High-throughput mass spectrometry methods have been developed to screen newborns for lysosomal storage disorders, allowing the implementation of newborn screening pilot studies in North America and Europe. It is currently feasible to diagnose Pompe, Fabry, Gaucher, Krabbe, and Niemann-Pick A/B diseases, as well as mucopolysaccharidosis I, by tandem mass spectrometry in dried blood spots, which offers considerable technical advantages compared with standard methodologies. We aimed to investigate whether the mass spectrometry methodology for lysosomal storage disease screening, originally developed for newborns, can also discriminate between affected patients and controls of various ages. METHODS: A total of 205 control individuals were grouped according to age and subjected to mass spectrometry quantification of lysosomal α-glucosidase, β-glucocerebrosidase, α-galactosidase, acid sphingomyelinase, galactocerebrosidase, and α−L-iduronidase activities. Additionally, 13 affected patients were analyzed. RESULTS: The median activities for each enzyme and each age group were determined. Enzyme activities were significantly lower in individuals aged older than 18 years compared with those in newborns. Affected patients presented enzymatic activities corresponding to less than 20% of the age-matched controls. CONCLUSIONS: Our data indicate that the mass spectrometry methodology can be used for the screening of lysosomal storage diseases in non-newborn patients. However, for some diseases, such as Fabry and mucopolysaccharidosis I, a combination of biochemical and clinical data may be necessary to achieve accurate diagnoses.

  20. Advanced Laser Architecture for Two-Step Laser Tandem Mass Spectrometer

    Science.gov (United States)

    Fahey, Molly E.; Li, Steven X.; Yu, Anthony W.; Getty, Stephanie A.

    2016-01-01

    Future astrobiology missions will focus on planets with significant astrochemical or potential astrobiological features, such as small, primitive bodies and the icy moons of the outer planets that may host diverse organic compounds. These missions require advanced instrument techniques to fully and unambiguously characterize the composition of surface and dust materials. Laser desorptionionization mass spectrometry (LDMS) is an emerging instrument technology for in situ mass analysis of non-volatile sample composition. A recent Goddard LDMS advancement is the two-step laser tandem mass spectrometer (L2MS) instrument to address the need for future flight instrumentation to deconvolve complex organic signatures. The L2MS prototype uses a resonance enhanced multi-photon laser ionization mechanism to selectively detect aromatic species from a more complex sample. By neglecting the aliphatic and inorganic mineral signatures in the two-step mass spectrum, the L2MS approach can provide both mass assignments and clues to structural information for an in situ investigation of non-volatile sample composition. In this paper we will describe our development effort on a new laser architecture that is based on the previously flown Lunar Orbiter Laser Altimeter (LOLA) laser transmitter for the L2MS instrument. The laser provides two discrete midinfrared wavelengths (2.8 m and 3.4 m) using monolithic optical parametric oscillators and ultraviolet (UV) wavelength (266 nm) on a single laser bench with a straightforward development path toward flight readiness.

  1. UPLC-MS/MS同时检测染发剂中三种二氨基酚类物质%Determinauon of 3 diaminopnenols in hair dyes by ultra performance liquid chromatography tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    曹鹏; 耿金培; 许红岩; 李晓玉; 李金强; 梁君妮; 沙美兰

    2011-01-01

    建立了超高效液相色谱-串联质谱( UPLC-MS/MS)同时检测染发剂中三种二氨基酚类物质(2,4-二氨基苯酚盐酸盐、2,4-二氨基苯甲醚盐酸盐、2,3-二氨基苯酚)含量的方法.样品经0.1%甲酸水溶液提取,正己烷净化后,用Waters ACQUITY BEH Shield RP18色谱柱进行分离,流动相为甲醇和5 mmol/L乙酸铵-0.1%甲酸溶液.分离后采用多反应监测模式进行检测,外标法定量.在优化实验条件下,三种化合物的线性范围为10 ~ 500.μg/L,相关系数均大于0.998.三种二氨基酚类化合物的检出限为3μg/kg,定量下限为10μg/kg,加标平均回收率为80.3%~113.5%,相对标准偏差均不高于8.6%.该方法适用于染发剂中三种二氨基酚类物质的定量及确证分析.%An ultra performance liquid chromatography-electrospray ionization triple-quadruple tandem mass speetrometric ( UPLC-ESI MS/MS) method has been established for the simultaneous determination of three diaminophenols, including 2,4-diaminophenol dihydrochloride, 2,4-diaminoanisole dihydrochloride, and 2,3-Diaminophenol, in hair dyes. The diaminophenols were extracted by water - 0. 1 % formic acid and cleaned up by n-hexane. The separation was carried out by an ACQUITY? BEH Shield RP18 column using methanol and 5 mmol/L ammonium acetate - 0. 1 % formic acid as the mobile phase. The target compounds were confirmed and quantified by MS-MS under multiple-reaction monitering ( MRM) mode with external standard method. Extraction and chromatographic conditions were optimized and the best separation was obtained. Under the optimal conditions, the calibration curves were linear in the range of 10 ~ 500 jxg/L for the three compounds with correlation coefficients more than 0.998. The limits of detection (LOD) were 3 fig/kg, and the limits of quantitation (LOQ) were 10 jxg/kg. The average recoveries of 3 diaminophenols were between 80.3% and 113. 5% with the relative standard deviations (RSDs) no more than 8

  2. Determination of Paralytic Shellfish Poisoning Toxins in Shellfish by Liquid Chromatography with Tandem Mass Spectrometry%液相色谱-串联质谱法检测贝类产品中麻痹性贝类毒素

    Institute of Scientific and Technical Information of China (English)

    母清林; 方杰; 王晓华; 胡颢琰; 曹柳燕; 张庆红

    2013-01-01

    建立了贝类组织中11种麻痹性贝类毒素的高效液相色谱-串联质谱分析方法,包括STX、dcSTX、NEO、dcNEO、GTX1-4、dcGTX2,3和GTX5(B1).贝类样品经含0.1%甲酸的80%(体积分数)乙腈水溶液超声提取后,经过冷冻分层,下层固体融化后通过HLB固相萃取小柱富集净化和10 000MWCO(Molecular Weight Cutoff)超滤管超滤截留,超滤液用于仪器分析.采用Zwitterionic亲水性相互作用色谱柱(250 mm×4.6 mm,5μm,德国)分离,在多反应监测模式下进行定性和定量分析.各组分在一定的范围内具有良好的线性关系,平均回收率大于60%,相对标准偏差小于20%(n=7).用该方法分析染毒的栉孔扇贝样品,证实了对PSP毒素具有良好的分析测定效果.%A liquid chromatography-electrospray ionization triple-quadruple tandem mass spectrometric method has been established for the determination of eleven kinds of paralytic shellfish poisoning toxins including STX, dcSTX, NEO, dcNEO, GTX1 -4, dcGTX2,3 andGTX5(B1). After being extracted using acetonitrile and water (80:20, V/V) including 0. 1 % formic acid, the solution was frozen to separate into two layers. To melt the solid, then the solution would be cleaned-up by solid phase extraction (SPE) on an Oasis HLB cartridge. In order to get rid of macromolecule compound, the sample was ultra filtrated with 10 000 MWCO ( Molecular Weight Cutoff) ultra-filtration device. The ultra-filtration solution would be analyzed. The sample would be separated on a Zwitterionic hydrophilic interaction liquid chromatography column ( 250 mm × 4. 6 mm, 5 μm ). The quantitative and confirmatory determinations of PSP were performed by multiple reactions monitoring mode. All components showed good linear relation in the suitable range. The mean recoveries were more than 60% and the relative standard deviations were less than 20% ( n = 7 ). The method has been applied to the analysis of samples contaminated with PSP toxins with

  3. Analysis of isorhamnetin-3-O-neohesperidoside in rat plasma by liquid chromatography/electrospray ionization tandem mass spectrometry and its application to pharmacokinetic studies%高效液相质谱联用法分析大鼠血浆中异鼠李素-3-O-新橙皮糖苷的浓度及其药代动力学研究

    Institute of Scientific and Technical Information of China (English)

    刘史佳; 陈佩东; 戴国梁; 居文政; 谢丽艳; 徐洁; 周玲; 丁安伟; 余伯阳

    2013-01-01

    目的:建立LC-MS/MS方法测定异鼠李素-3-O-新橙皮糖苷的浓度并研究其在大鼠体内的药代动力学.方法:8只大鼠分别尾静脉注射异鼠李素-3-O-新橙皮糖苷5 mg·kg-1.建立并确证高灵敏度的液质联用法分析大鼠血浆中异鼠李素-3-O-新橙皮糖苷的浓度,采用芦丁作为内标.采用甲醇蛋白沉淀法提取血浆中的异鼠李素-3-O-新橙皮糖苷和芦丁.然后用10 mmol·L-1的乙酸铵/甲醇(20∶80,V/V)的流动相在C1色谱柱(150 mm×2.1mm,I.D.,5μm)上进行洗脱并采用多反应检测的方式进行质谱分析.结果:异鼠李素-3-O-新橙皮糖苷的在大鼠血浆中的线性范围为0.01-10μg·mL-1.其定量下限为0.01 μg·mL-1.结论:该方法可以用于测定大鼠血浆中异鼠李素-3-0-新橙皮糖苷的浓度.

  4. Atmospheric-Pressure Chemical Ionization Tandem Mass Spectrometry (APGC/MS/MS) an Alternative to High-Resolution Mass Spectrometry (HRGC/HRMS) for the Determination of Dioxins

    NARCIS (Netherlands)

    Bavel, Van Bert; Geng, Dawei; Cherta, Laura; Nácher-Mestre, Jaime; Portolés, Tania; Ábalos, Manuela; Sauló, Jordi; Abad, Esteban; Dunstan, Jody; Jones, Rhys; Kotz, Alexander; Winterhalter, Helmut; Malisch, Rainer; Traag, Wim; Hagberg, Jessika; Ericson Jogsten, Ingrid; Beltran, Joaquim; Hernández, Félix

    2015-01-01

    The use of a new atmospheric-pressure chemical ionization source for gas chromatography (APGC) coupled with a tandem quadrupole mass spectrometry (MS/MS) system, as an alternative to high-resolution mass spectrometry (HRMS), for the determination of PCDDs/PCDFs is described. The potential of usin

  5. Mining Large Scale Tandem Mass Spectrometry Data for Protein Modifications Using Spectral Libraries.

    Science.gov (United States)

    Horlacher, Oliver; Lisacek, Frederique; Müller, Markus

    2016-03-01

    Experimental improvements in post-translational modification (PTM) detection by tandem mass spectrometry (MS/MS) has allowed the identification of vast numbers of PTMs. Open modification searches (OMSs) of MS/MS data, which do not require prior knowledge of the modifications present in the sample, further increased the diversity of detected PTMs. Despite much effort, there is still a lack of functional annotation of PTMs. One possibility to narrow the annotation gap is to mine MS/MS data deposited in public repositories and to correlate the PTM presence with biological meta-information attached to the data. Since the data volume can be quite substantial and contain tens of millions of MS/MS spectra, the data mining tools must be able to cope with big data. Here, we present two tools, Liberator and MzMod, which are built using the MzJava class library and the Apache Spark large scale computing framework. Liberator builds large MS/MS spectrum libraries, and MzMod searches them in an OMS mode. We applied these tools to a recently published set of 25 million spectra from 30 human tissues and present tissue specific PTMs. We also compared the results to the ones obtained with the OMS tool MODa and the search engine X!Tandem.

  6. Application of tandem accelerator mass spectrometor to the chronological study of archaeological samples on Ryukyu Islands

    Energy Technology Data Exchange (ETDEWEB)

    Taira, Hatsuo; Higa, Kenichi; Nakai, Nobuyuki; Nakamura, Toshio.

    1987-10-01

    Along with the urbanization of rural areas on Ryukyu Islands, many shell mounds and pre-historic sites have been found in resent years. Chrological studies of shell samples from these mounds will lead to the better understanding of cultural background for the pre-historic human activities on the Ryukyu Islands. C-14 dating by beta counting is the common method to obtain the ages of the archaeological samples. It is, however, very limited in obtaining the absolute ages by the above mehtod due to the large sample sizes required and time consuming. There are many newly obtained archaeological samples left unstudied in detail. The alternate is a method called Tandem Accelerator Mass Spectrometer (AMS) installed at Nagoya University, which is composed of the tandem type accelerator to measure very low concentration of C-14 in archaeological samples. The system has been designed particularly to measure the radio-carbon and has advantages of being small sample size and very little time consuming for C-14 measurement as compared with the beta counting. It is the aim of this work to apply the above AMS for obtaining the absolute ages of the archaeological samples. The results agreed well with those estimated by the Erthenware method (relative method of dating), which ranged from 500 to 6000 y.b.p. The results may be helpful for the chronological arrangement of the samples and for the understanding of pre-historical human activities on the Ryukyu Islands.

  7. Mining Large Scale Tandem Mass Spectrometry Data for Protein Modifications Using Spectral Libraries.

    Science.gov (United States)

    Horlacher, Oliver; Lisacek, Frederique; Müller, Markus

    2016-03-01

    Experimental improvements in post-translational modification (PTM) detection by tandem mass spectrometry (MS/MS) has allowed the identification of vast numbers of PTMs. Open modification searches (OMSs) of MS/MS data, which do not require prior knowledge of the modifications present in the sample, further increased the diversity of detected PTMs. Despite much effort, there is still a lack of functional annotation of PTMs. One possibility to narrow the annotation gap is to mine MS/MS data deposited in public repositories and to correlate the PTM presence with biological meta-information attached to the data. Since the data volume can be quite substantial and contain tens of millions of MS/MS spectra, the data mining tools must be able to cope with big data. Here, we present two tools, Liberator and MzMod, which are built using the MzJava class library and the Apache Spark large scale computing framework. Liberator builds large MS/MS spectrum libraries, and MzMod searches them in an OMS mode. We applied these tools to a recently published set of 25 million spectra from 30 human tissues and present tissue specific PTMs. We also compared the results to the ones obtained with the OMS tool MODa and the search engine X!Tandem. PMID:26653734

  8. Confirmatory analysis of firocoxib in bovine milk by rapid resolution liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Dowling, Geraldine; Gallo, Pasquale; Regan, Liam

    2009-02-15

    A rapid method has been developed to analyse for firocoxib (FIRO) residue in bovine milk. Milk samples were extracted with acetonitrile and sample extracts were purified on Evolute ABN solid phase extraction cartridges. Aliquots were analysed by rapid resolution liquid chromatography tandem mass spectrometry (RRLC-MS/MS). The method was validated in bovine milk, according to the criteria defined in Commission Decision 2002/657/EC. The decision limit (CCalpha) was 1.18ng/mL and for the detection capability a (CCbeta) value of 2.02ng/mL was obtained. The measurement uncertainty of the method was 27%. Fortifying bovine milk samples (n=18) in three separate assays, show the accuracy of the method to be between 96 and 105%. The precision of the method, expressed as RSD values for the within-lab reproducibility at the three levels of fortification (5, 7.5 and 10ng/mL) was less than 11% respectively.

  9. Tandem Mass Spectrometry Detection of Quorum Sensing Activity in Multidrug Resistant Clinical Isolate Acinetobacter baumannii

    Directory of Open Access Journals (Sweden)

    Kok-Gan Chan

    2014-01-01

    Full Text Available Many Proteobacteria communicate via production followed by response of quorum sensing molecules, namely, N-acyl homoserine lactones (AHLs. These molecules consist of a lactone moiety with N-acyl side chain with various chain lengths and degrees of saturation at C-3 position. AHL-dependent QS is often associated with regulation of diverse bacterial phenotypes including the expression of virulence factors. With the use of biosensor and high resolution liquid chromatography tandem mass spectrometry, the AHL production of clinical isolate A. baumannii 4KT was studied. Production of short chain AHL, namely, N-hexanoyl-homoserine lactone (C6-HSL and N-octanoyl-homoserine lactone (C8-HSL, was detected.

  10. Determination of Sex Hormones in Antler Velvet by High Performance Liquid Chromatography Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    LU Chun-mei; WANG Ming-tai; MU Jun; BAI Yu-ping; DU Jian-shi; ZHANG Han-qi; WANG Jian-wei

    2012-01-01

    Eighteen sex hormones in antler velvet were determined by high performance liquid chromatography tandem mass spectrometry.The solid phase extraction was applied to eliminating the matrix effect.The experimental conditions were examined and optimized.Under the optimal conditions,the proposed method provides the good linearities and determination limits(0.2-1.0 μg/kg)of the analytes investigated.The recoveries ranging from 72.3% to 149.5% were obtained for the target analytes at two concentration levels.This method was applied to the determination of eighteen sex hormones in different kinds of antler velvet samples and the obtained results are satisfactory.The results indicate that the proposed method is suitable for the determination of sex hormones in antler velvet samples.

  11. Protonation Sites, Tandem Mass Spectrometry and Computational Calculations of o-Carbonyl Carbazolequinone Derivatives

    Science.gov (United States)

    Martínez-Cifuentes, Maximiliano; Clavijo-Allancan, Graciela; Zuñiga-Hormazabal, Pamela; Aranda, Braulio; Barriga, Andrés; Weiss-López, Boris; Araya-Maturana, Ramiro

    2016-01-01

    A series of a new type of tetracyclic carbazolequinones incorporating a carbonyl group at the ortho position relative to the quinone moiety was synthesized and analyzed by tandem electrospray ionization mass spectrometry (ESI/MS-MS), using Collision-Induced Dissociation (CID) to dissociate the protonated species. Theoretical parameters such as molecular electrostatic potential (MEP), local Fukui functions and local Parr function for electrophilic attack as well as proton affinity (PA) and gas phase basicity (GB), were used to explain the preferred protonation sites. Transition states of some main fragmentation routes were obtained and the energies calculated at density functional theory (DFT) B3LYP level were compared with the obtained by ab initio quadratic configuration interaction with single and double excitation (QCISD). The results are in accordance with the observed distribution of ions. The nature of the substituents in the aromatic ring has a notable impact on the fragmentation routes of the molecules. PMID:27399676

  12. Measurement of hydroxysafflor yellow A in human urine by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Li, Chang-Yin; Chu, Ji-Hong; Zhang, Jun; Sun, Bing-Ting; Dai, Guo-Liang; Liu, Shi-Jia; Ju, Wen-Zheng

    2015-01-01

    A rapid and specific high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the quantification of hydroxysafflor yellow A (HSYA) in human urine with isorhamnetin-3-O-neohespeidoside as internal standard (IS). HSYA and IS were extracted from urine samples by simple solid-phase extraction and separated on an Agilent Zorbax SB C18 column (4.6 mm × 150 mm, 5 μm) with the mobile phase of 0.2 mM ammonium acetate: methanol (30/70, v/v) at a flow rate of 0.4 mL/min. Polar endogenous interferences eluted in 0.1-2.5 min were switched into waste channel by the Valve Valco, to reduce the possible matrix effect for MS detection in each run. The MS detection of analytes was performed on a tandem mass spectrometer equipped with an electrospray ionization source in negative mode using multiple-reaction monitoring. The MS/MS ion transitions monitored were m/z 611.3→491.2 for HSYA and m/z 623.2→299.2 for IS. The method was fully validated for selectivity, sensitivity, linearity, precision, accuracy, recovery, matrix effect and stability, and then was applied to the urinary excretion study of injectable powder of pure HSYA in healthy Chinese volunteers for the first time. The results suggested that urine was the main excretion way of HSYA in healthy volunteers, further demonstrating the feasibility and necessity of our current method. PMID:25463208

  13. Determination of nitrofuran and chloramphenicol residues by high resolution mass spectrometry versus tandem quadrupole mass spectrometry.

    Science.gov (United States)

    Kaufmann, A; Butcher, P; Maden, K; Walker, S; Widmer, M

    2015-03-01

    An ultra-high performance liquid chromatography based method, coupled to high resolution mass spectrometry (UHPLC-HRMS), was developed to permit the detection and quantification of various nitrofuran and chloramphenicol residues in a number of animal based food products. This method is based on the hydrolysis of covalently bound metabolites and derivatization with 2-nitrobenzaldehyde. Clean-up is achieved by a liquid/liquid and a reversed phase/solid phase extraction. Not only are the four conventional nitrofurans (nitrofurantoin, furazolidone, nitrofurazone and furaltadone) detected, but also nifursol, nitrovin and nifuroxazide. Furthermore, an underivatizable nitrofuran (nifurpirinol) and another banned drug (chloramphenicol) can be quantified as well. The compounds are detected in the form of their precursor ions, [M+H](+) and [M-H](-), respectively. The mass resolving power of 70,000 FWHM, and the applied mass window ensure sufficient selectivity and sensitivity. Confirmation is obtained by monitoring the HRMS resolved product ions which were derived from the unit-mass resolved precursor ions. The multiplexing capability of the utilized Orbitrap instrument provides not only highly selective, but also sensitive confirmatory signals. This method has been validated according to the CD 2002/657/EC for the following matrices: muscle, liver, kidney, fish, honey, eggs and milk. PMID:25682427

  14. Decoding Split and Pool Combinatorial Libraries with Electron-Transfer Dissociation Tandem Mass Spectrometry

    Science.gov (United States)

    Sarkar, Mohosin; Pascal, Bruce D.; Steckler, Caitlin; Aquino, Claudio; Micalizio, Glenn C.; Kodadek, Thomas; Chalmers, Michael J.

    2013-07-01

    Screening of bead-based split and pool combinatorial chemistry libraries is a powerful approach to aid the discovery of new chemical compounds able to interact with, and modulate the activities of, protein targets of interest. Split and pool synthesis provides for large and well diversified chemical libraries, in this case comprised of oligomers generated from a well-defined starting set. At the end of the synthesis, each bead in the library displays many copies of a unique oligomer sequence. Because the sequence of the oligomer is not known at the time of screening, methods for decoding of the sequence of each screening "hit" are essential. Here we describe an electron-transfer dissociation (ETD) based tandem mass spectrometry approach for the decoding of mass-encoded split and pool libraries. We demonstrate that the newly described "chiral oligomers of pentenoic amides (COPAs)" yield non-sequence-specific product ions upon collisional activated dissociation; however, complete sequence information can be obtained with ETD. To aid in the decoding of libraries from MS and MS/MS data, we have incorporated 79Br/81Br isotope "tags" to differentiate N- and C-terminal product ions. In addition, we have created "Hit-Find," a software program that allows users to generate libraries in silico . The user can then search all possible members of the chemical library for those that fall within a user-defined mass error.

  15. Characterization of N,N-dimethyl amino acids by electrospray ionization-tandem mass spectrometry.

    Science.gov (United States)

    Naresh Chary, V; Sudarshana Reddy, B; Kumar, Ch Dinesh; Srinivas, R; Prabhakar, S

    2015-05-01

    Methylation is an essential metabolic process for a number of critical reactions in the body. Methyl groups are involved in the healthy function of the body life processes, by conducting methylation process involving specific enzymes. In these processes, various amino acids are methylated, and the occurrence of methylated amino acids in nature is diverse. Nowadays, mass-spectrometric-based identification of small molecules as biomarkers for diseases is a growing research. Although all dimethyl amino acids are metabolically important molecules, mass spectral data are available only for a few of them in the literature. In this study, we report synthesis and characterization of all dimethyl amino acids, by electrospray ionization-tandem mass spectrometry (MS/MS) experiments on protonated molecules. The MS/MS spectra of all the studied dimethyl amino acids showed preliminary loss of H2O + CO to form corresponding immonium ions. The other product ions in the spectra are highly characteristic of the methyl groups on the nitrogen and side chain of the amino acids. The amino acids, which are isomeric and isobaric with the studied dimethyl amino acids, gave distinctive MS/MS spectra. The study also included MS/MS analysis of immonium ions of dimethyl amino acids that provide information on side chain structure, and it is further tested to determine the N-terminal amino acid of the peptides.

  16. Simplified analysis of glyphosate and aminomethylphosphonic acid in water, vegetation, and soil by liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    A simple, fast, efficient, and sensitive method was developed for analysis of glyphosate and its degradate, aminomethylphosphonic acid (AMPA), in water, vegetation, and soil. Aqueous extracts were passed through reverse phase and cation exchange columns and directly injected into a tandem mass spect...

  17. Simultaneous determination of estrogens and progestogens in honey using high performance liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    This work describes the development and validation of a method for the simultaneous determination of 13 estrogens and progestogens in honey by high performance liquid chromatography-tandem mass spectrometry. The target compounds were preconcentrated by solid phase extraction. Pretreatment variables ...

  18. Rapid detection of pesticides not amenable to multi-residue methods by flow injection-tandem mass spectrometry

    NARCIS (Netherlands)

    Mol, J.G.J.; Dam, van R.C.J.

    2014-01-01

    Flow injection combined with tandem mass spectrometry (MS/MS) was investigated for the rapid detection of highly polar pesticides that are not amenable to multi-residue methods because they do not partition into organic solvents and require dedicated chromatographic conditions. The pesticides includ

  19. Generic solid phase extraction-liquid chromatography-tandem mass spectrometry method for fast determination of drugs in biological fluids

    NARCIS (Netherlands)

    Schellen, A.; Ooms, B.; Lagemaat, D. van de; Vreeken, R.; Dongen, W.D. van

    2003-01-01

    A generic method was developed for the fast determination of a wide range of drugs in serum or plasma. The methodology comprises generic solid-phase extraction, on-line coupled to gradient HPLC with tandem mass spectrometric detection (SPE-LC-MS/MS). The individual components of the SPE-LC-MS/MS sys

  20. Clinical validation of cutoff target ranges in newborn screening of metabolic disorders by tandem mass spectrometry : A worldwide collaborative project

    NARCIS (Netherlands)

    McHugh, David M. S.; Cameron, Cynthia A.; Abdenur, Jose E.; Abdulrahman, Mahera; Adair, Ona; Al Nuaimi, Shahira Ahmed; Ahlman, Henrik; Allen, Jennifer J.; Antonozzi, Italo; Archer, Shaina; Au, Sylvia; Auray-Blais, Christiane; Baker, Mei; Bamforth, Fiona; Beckmann, Kinga; Pino, Gessi Bentz; Berberich, Stanton L.; Binard, Robert; Boemer, Francois; Bonham, Jim; Breen, Nancy N.; Bryant, Sandra C.; Caggana, Michele; Caldwell, S. Graham; Camilot, Marta; Campbell, Carlene; Carducci, Claudia; Cariappa, Rohit; Carlisle, Clover; Caruso, Ubaldo; Cassanello, Michela; Miren Castilla, Ane; Castineiras Ramos, Daisy E.; Chakraborty, Pranesh; Chandrasekar, Ram; Ramos, Alfredo Chardon; Cheillan, David; Chien, Yin-Hsiu; Childs, Thomas A.; Chrastina, Petr; Sica, Yuri Cleverthon; Cocho de Juan, Jose Angel; Elena Colandre, Maria; Cornejo Espinoza, Veronica; Corso, Gaetano; Currier, Robert; Cyr, Denis; Czuczy, Noemi; D'Apolito, Oceania; Davis, Tim; de Sain-Van der Velden, Monique G.; Delgado Pecellin, Carmen; Di Gangi, Iole Maria; Di Stefano, Cristina Maria; Dotsikas, Yannis; Downing, Melanie; Downs, Stephen M.; Dy, Bonifacio; Dymerski, Mark; Rueda, Inmaculada; Elvers, Bert; Eaton, Roger; Eckerd, Barbara M.; El Mougy, Fatma; Eroh, Sarah; Espada, Mercedes; Evans, Catherine; Fawbush, Sandy; Fijolek, Kristel F.; Fisher, Lawrence; Franzson, Leifur; Frazier, Dianne M.; Garcia, Luciana R. C.; Garcia-Valdecasas Bermejo, Maria Sierra; Gavrilov, Dimitar; Gerace, Rosemarie; Giordano, Giuseppe; Irazabal, Yolanda Gonzalez; Greed, Lawrence C.; Grier, Robert; Grycki, Elyse; Gu, Xuefan; Gulamali-Majid, Fizza; Hagar, Arthur F.; Han, Lianshu; Hannon, W. Harry; Haslip, Christa; Hassan, Fayza Abdelhamid; He, Miao; Hietala, Amy; Himstedt, Leslie; Hoffman, Gary L.; Hoffman, William; Hoggatt, Philis; Hopkins, Patrick V.; Hougaard, David M.; Hughes, Kerie; Hunt, Patricia R.; Hwu, Wuh-Liang; Hynes, June; Ibarra-Gonzalez, Isabel; Ingham, Cindy A.; Ivanova, Maria; Jacox, Ward B.; John, Catharine; Johnson, John P.; Jonsson, Jon J.; Karg, Eszter; Kasper, David; Klopper, Brenda; Katakouzinos, Dimitris; Khneisser, Issam; Knoll, Detlef; Kobayashi, Hirinori; Koneski, Ronald; Kozich, Viktor; Kouapei, Rasoul; Kohlmueller, Dirk; Kremensky, Ivo; la Marca, Giancarlo; Lavochkin, Marcia; Lee, Soo-Youn; Lehotay, Denis C.; Lemes, Aida; Lepage, Joyce; Lesko, Barbara; Lewis, Barry; Lim, Carol; Linard, Sharon; Lindner, Martin; Lloyd-Puryear, Michele A.; Lorey, Fred; Loukas, Yannis L.; Luedtke, Julie; Maffitt, Neil; Magee, J. Fergall; Manning, Adrienne; Manos, Shawn; Marie, Sandrine; Hadachi, Sonia Marchezi; Marquardt, Gregg; Martin, Stephen J.; Matern, Dietrich; Gibson, Stephanie K. Mayfield; Mayne, Philip; McCallister, Tonya D.; McCann, Mark; McClure, Julie; McGill, James J.; McKeever, Christine D.; McNeilly, Barbara; Morrissey, Mark A.; Moutsatsou, Paraskevi; Mulcahy, Eleanor A.; Nikoloudis, Dimitris; Norgaard-Pedersen, Bent; Oglesbee, Devin; Oltarzewski, Mariusz; Ombrone, Daniela; Ojodu, Jelili; Papakonstantinou, Vagelis; Reoyo, Sherly Pardo; Park, Hyung-Doo; Pasquali, Marzia; Pasquini, Elisabetta; Patel, Pallavi; Pass, Kenneth A.; Peterson, Colleen; Pettersen, Rolf D.; Pitt, James J.; Poh, Sherry; Pollak, Arnold; Porter, Cory; Poston, Philip A.; Price, Ricky W.; Queijo, Cecilia; Quesada, Jonessy; Randell, Edward; Ranieri, Enzo; Raymond, Kimiyo; Reddic, John E.; Reuben, Alejandra; Ricciardi, Charla; Rinaldo, Piero; Rivera, Jeff D.; Roberts, Alicia; Rocha, Hugo; Roche, Geraldine; Greenberg, Cheryl Rochman; Egea Mellado, Jose Maria; Jess Juan-Fita, Maria; Ruiz, Consuelo; Ruoppolo, Margherita; Rutledge, S. Lane; Ryu, Euijung; Saban, Christine; Sahai, Inderneel; Salazar Garcia-Blanco, Maria Isabel; Santiago-Borrero, Pedro; Schenone, Andrea; Schoos, Roland; Schweitzer, Barb; Scott, Patricia; Seashore, Margretta R.; Seeterlin, Mary A.; Sesser, David E.; Sevier, Darrin W.; Shone, Scott M.; Sinclair, Graham; Skrinska, Victor A.; Stanley, Eleanor L.; Strovel, Erin T.; Jones, April L. Studinski; Sunny, Sherlykutty; Takats, Zoltan; Tanyalcin, Tijen; Teofoli, Francesca; Thompson, J. Robert; Tomashitis, Kathy; Domingos, Mouseline Torquado; Torres, Jasmin; Torres, Rosario; Tortorelli, Silvia; Turi, Sandor; Turner, Kimberley; Tzanakos, Nick; Valiente, Alf G.; Vallance, Hillary; Vela-Amieva, Marcela; Vilarinho, Laura; von Doebeln, Ulrika; Vincent, Marie-Francoise; Vorster, B. Chris; Watson, Michael S.; Webster, Dianne; Weiss, Sheila; Wilcken, Bridget; Wiley, Veronica; Williams, Sharon K.; Willis, Sharon A.; Woontner, Michael; Wright, Katherine; Yahyaoui, Raquel

    2011-01-01

    Purpose: To achieve clinical validation of cutoff values for newborn screening by tandem mass spectrometry through a worldwide collaborative effort. Methods: Cumulative percentiles of amino acids and acylcarnitines in dried blood spots of approximately 25-30 million normal newborns and 10,742 deiden

  1. Regioisomers of octanoic acid-containing structured triacylglycerols analyzed by tandem mass spectrometry using ammonia negative ion chemical ionization

    DEFF Research Database (Denmark)

    Kurvinen, J.P.; Mu, Huiling; Kallio, H.;

    2001-01-01

    Tandem mass spectrometry based on ammonia negative ion chemical ionization and sample introduction via direct exposure probe was applied to analysis of regioisomeric structures of octanoic acid containing structured triacylglycerols (TAG) of type MML, MLM, MLL, and LML (M, medium-chain fatty acid...

  2. Determination of kava lactones in food supplements by liquid chromatography-atmospheric pressure chemical ionisation tandem mass spectrometry

    NARCIS (Netherlands)

    Bobeldijk, I.; Boonzaaijer, G.; Spies-Faber, E.J.; Vaes, W.H.J.

    2005-01-01

    Reversed-phase liquid chromatography and detection with atmospheric pressure chemical ionisation tandem mass spectrometry was used for the determination of kava extracts in herbal mixtures. One percent of kava extract can be detected, corresponding to approximately 0.05-0.2 mg/g of the individual ka

  3. Probability-Based Pattern Recognition and Statistical Framework for Randomization: Modeling Tandem Mass Spectrum/Peptide Sequence False Match Frequencies

    Science.gov (United States)

    Estimating and controlling the frequency of false matches between a peptide tandem mass spectrum and candidate peptide sequences is an issue pervading proteomics research. To solve this problem, we designed an unsupervised pattern recognition algorithm for detecting patterns with various lengths fr...

  4. Liquid chromatography-tandem mass spectrometry assay for the quantification of free and total sialic acid in human cerebrospinal fluid.

    NARCIS (Netherlands)

    Ham, M. van der; Koning, T.J. de; Lefeber, D.J.; Fleer, A.; Prinsen, B.H.; Sain-van der Velden, M.G. de

    2010-01-01

    BACKGROUND: Analysis of sialic acid (SA) metabolites in cerebrospinal fluid (CSF) is important for clinical diagnosis. In the present study, a high-performance liquid chromatography-tandem mass spectrometry (HPLC/MS/MS) method for free sialic acid (FSA) and total sialic acid (TSA) in human CSF was v

  5. Electrospray ionization quadrupole time-of-flight tandem mass spectrometric analysis of hexamethylenediamine-modified maltodextrin and dextran

    NARCIS (Netherlands)

    Sisu, E.; Bosker, W.T.E.; Norde, W.; Slaghek, T.M.; Timmermans, J.W.; Peter-Katalinić, J.; Cohen-Stuart, M.A.; Zamfir, A.D.

    2006-01-01

    A combined methodology for obtaining at the preparative scale and characterization by nanoelectrospray ionization (nanoESI) quadrupole time-of-flight (QTOF) mass spectrometry (MS) and tandem MS (MS/MS) of linear polysaccharides modified at the reducing end is presented. Two polydisperse maltodextrin

  6. An Undergraduate Experiment for the Measurement of Perfluorinated Surfactants in Fish Liver by Liquid Chromatography-Tandem Mass Spectrometry

    Science.gov (United States)

    Stock, Naomi L.; Martin, Jonathan W.; Ye, Yun; Mabury, Scott A.

    2007-01-01

    A laboratory experiment that provides students a hands-on introduction to the specific techniques of liquid chromatography-tandem mass spectrometry (LC-MS/MS) and electrospray ionization is presented. The students can thus practice the analytical principles of sample extraction, detection, quantification, and quality control using a fresh fish…

  7. Functional group composition of ambient and source organic aerosols determined by tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dron, J.; El Haddad, I.; Temime-Roussel, B.; Wortham, H.; Marchand, N. [Univ Aix Marseille, CNRS, Lab Chim Provence, Equipe Instrumentat and React Atmospher, UMR 6264, F-13331 Marseille 3 (France); Jaffrezo, J.L. [Univ Grenoble 1, CNRS, UMR 5183, Lab Glaciol and Geophys Environm, F-38402 St Martin Dheres (France)

    2010-07-01

    The functional group composition of various organic aerosols (OA) is investigated using a recently developed analytical approach based on atmospheric pressure chemical ionisation-tandem mass spectrometry (APCIMS/MS). The determinations of three functional groups contents are performed quantitatively by neutral loss (carboxylic and carbonyl groups, R-COOH and R-CO-R' respectively) and precursor ion (nitro groups, R-NO{sub 2}) scanning modes of a tandem mass spectrometer. Major organic aerosol sources are studied: vehicular emission and wood combustion for primary aerosol sources; and a secondary organic aerosol (SOA) produced through photooxidation of o-xylene. The results reveal significant differences in the functional group contents of these source aerosols. The laboratory generated SOA is dominated by carbonyls while carboxylics are preponderate in the wood combustion particles. On the other hand, vehicular emissions are characterised by a strong nitro content. The total amount of the three functional groups accounts for 1.7% (vehicular) to 13.5% (o-xylene photooxidation) of the organic carbon. Diagnostic functional group ratios are then used to tentatively discriminate sources of particles collected in an urban background environment located in an Alpine valley (Chamonix, France) during a strong winter pollution event. The three functional groups under study account for a total functionalization rate of 2.2 to 3.8% of the organic carbon in this ambient aerosol, which is also dominated by carboxylic moieties. In this particular case study of a deep alpine valley during winter, we show that the nitro- and carbonyl-to-carboxylic diagnostic ratios can be a useful tool to discriminate sources. In these conditions, the total OA concentrations are highly dominated by wood combustion OA. This result is confirmed by an organic markers source apportionment approach which assess a wood burning organic carbon contribution of about 60%. Finally, examples of functional

  8. Functional group composition of ambient and source organic aerosols determined by tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    J. Dron

    2010-08-01

    Full Text Available The functional group composition of various organic aerosols (OA is investigated using a recently developed analytical approach based on atmospheric pressure chemical ionisation-tandem mass spectrometry (APCI-MS/MS. The determinations of three functional groups contents are performed quantitatively by neutral loss (carboxylic and carbonyl groups, R-COOH and R-CO-R´ respectively and precursor ion (nitro groups, R-NO2 scanning modes of a tandem mass spectrometer. Major organic aerosol sources are studied: vehicular emission and wood combustion for primary aerosol sources; and a secondary organic aerosol (SOA produced through photooxidation of o-xylene. The results reveal significant differences in the functional group contents of these source aerosols. The laboratory generated SOA is dominated by carbonyls while carboxylics are preponderate in the wood combustion particles. On the other hand, vehicular emissions are characterised by a strong nitro content. The total amount of the three functional groups accounts for 1.7% (vehicular to 13.5% (o-xylene photooxidation of the organic carbon. Diagnostic functional group ratios are then used to tentatively discriminate sources of particles collected in an urban background environment located in an Alpine valley (Chamonix, France during a strong winter pollution event. The three functional groups under study account for a total functionalisation rate of 2.2 to 3.8% of the organic carbon in this ambient aerosol, which is also dominated by carboxylic moieties. In this particular case study of a deep alpine valley during winter, we show that the nitro- and carbonyl-to-carboxylic diagnostic ratios can be a useful tool to discriminate sources. In these conditions, the total OA concentrations are highly dominated by wood combustion OA. This result is confirmed by an organic markers source apportionment approach which assess a wood burning organic carbon contribution of about 60

  9. Functional group composition of ambient and source organic aerosols determined by tandem mass spectrometry

    International Nuclear Information System (INIS)

    The functional group composition of various organic aerosols (OA) is investigated using a recently developed analytical approach based on atmospheric pressure chemical ionisation-tandem mass spectrometry (APCIMS/MS). The determinations of three functional groups contents are performed quantitatively by neutral loss (carboxylic and carbonyl groups, R-COOH and R-CO-R' respectively) and precursor ion (nitro groups, R-NO2) scanning modes of a tandem mass spectrometer. Major organic aerosol sources are studied: vehicular emission and wood combustion for primary aerosol sources; and a secondary organic aerosol (SOA) produced through photooxidation of o-xylene. The results reveal significant differences in the functional group contents of these source aerosols. The laboratory generated SOA is dominated by carbonyls while carboxylics are preponderate in the wood combustion particles. On the other hand, vehicular emissions are characterised by a strong nitro content. The total amount of the three functional groups accounts for 1.7% (vehicular) to 13.5% (o-xylene photooxidation) of the organic carbon. Diagnostic functional group ratios are then used to tentatively discriminate sources of particles collected in an urban background environment located in an Alpine valley (Chamonix, France) during a strong winter pollution event. The three functional groups under study account for a total functionalization rate of 2.2 to 3.8% of the organic carbon in this ambient aerosol, which is also dominated by carboxylic moieties. In this particular case study of a deep alpine valley during winter, we show that the nitro- and carbonyl-to-carboxylic diagnostic ratios can be a useful tool to discriminate sources. In these conditions, the total OA concentrations are highly dominated by wood combustion OA. This result is confirmed by an organic markers source apportionment approach which assess a wood burning organic carbon contribution of about 60%. Finally, examples of functional group mass

  10. Direct Measurement of Free Estradiol in Human Serum and Plasma by Equilibrium Dialysis-Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Ray, Julie A; Kushnir, Mark M; Rockwood, Alan L; Meikle, A Wayne

    2016-01-01

    We describe a direct method of measurement of free estradiol using equilibrium dialysis followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Serum aliquots and internal standards are extracted by liquid-liquid extraction using methyl-tert-butyl ether (MTBE) followed by derivatization with dansyl chloride. An API 5500 mass spectrometer operated in positive electrospray mode is used for detection. PMID:26602122

  11. Planetary In Situ Sample Analysis with Tandem Two-Step Laser Mass Spectrometry

    Science.gov (United States)

    Brinckerhoff, W. B.; Getty, S. A.; Cornish, T. J.; Ecelberger, S. A.; Li, X.; Merrill Floyd, M. A.; Arevalo, R.; Elsila, J.; Callahan, M. P.

    2012-12-01

    -) and organic moieties. Second, by focusing a separate "post-ionization" laser pulse just above the sample surface, we can achieve two-step laser mass spectrometry, or L2MS, in the same highly-miniaturized TOF-MS. L2MS enables selective analysis of aromatic organics even in the presence of a complex mineral matrix. Finally, by introducing an ion optical gate in the flight path, we are able to take advantage of the broad focusing capabilities of the "curved field" reflectron at the core of the TOF-MS to achieve pseudo-tandem structural analysis of selected organics. The high-speed gate is used to admit only the molecular ion/s of interest into the reflectron. Diagnostic fragments of the ion/s obtained through metastable decay or active collision-induced dissociation (CID) remain in focus despite having widely variable velocities and masses. As such even molecular isomers with differing fragmentation pathways may be distinguished through a series of pseudo-tandem mass spectra that could be obtained in an automatic process during a mission. The "real-world" benefits of these enhancements are being fully characterized using a set of synthetic and natural standard samples as well as several planetary analogs and meteorites.

  12. Analyses of Phytohormones in Coconut (Cocos Nucifera L. Water Using Capillary Electrophoresis-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Swee Ngin Tan

    2014-12-01

    Full Text Available Capillary electrophoresis (CE coupled with mass spectrometry (MS or tandem mass spectrometry (MS/MS is reported as an alternative and potentially useful method for the simultaneous analysis of various classes of phytohormones with diversified structures, including indole-3-acetic acid (IAA, indole-3-butyric acid (IBA, abscisic acid (ABA, gibberellic acid (GA, zeatin (Z, N6-benzyladenine (BA, α-naphthaleneacetic acid (NAA and 2,4-dichlorophenoxyacetic acid (2,4-D. The key to the CE-MS/MS analysis was based on electroosmotic flow reversal using a cationic polymer-coated capillary. Under optimum conditions, a baseline separation of eight phytohormones was accomplished within 30 min using 60 mM ammonium formate/formic acid buffer of pH 3.8 with −20 kV as the separation voltage. The accessibility of MS/MS together with the characterization by migration properties obtained by CE allows for the development of CE-MS/MS as an emerging potential method for the analysis of different classes of phytohormones in a single run. The utility of the CE-MS/MS method was demonstrated by the comprehensive screening of phytohormones in coconut (Cocos nucifera L. water after pre-concentration and purification through solid-phase extraction (SPE cartridge. IAA, ABA, GA and Z were detected and quantified in the purified coconut water extract sample.

  13. Poiseuille flow-induced vibrations of two tandem circular cylinders with different mass ratios

    Science.gov (United States)

    Jiang, Ren-Jie; Lin, Jian-Zhong

    2016-06-01

    Flow-induced vibrations of two tandem circular cylinders with different mass ratios confined between two parallel walls are numerically studied via a lattice Boltzmann method. With fixed Reynolds number Re = 100 and blockage ratio β = 1/4, the effects of mass ratio m* = [0.0625, 16] and streamwise separation between two cylinders S/D = [1.125, 10] on the cylinder motions and vortex wake modes are investigated. A variety of distinct cylinder motion regimes involving the symmetric periodic vibration, biased quasi-periodic vibration, beating vibration, and steady regimes, with the corresponding wake structures, e.g., two rows of alternately rotating vortices, a single row of same-sign vortices, and steady wake, are observed. For each current case, the cylinder motion type is exclusive and in the binary oscillation regime, both cylinders always vibrate at a common primary frequency. The lighter cylinder usually oscillates at a larger amplitude than the heavier one, while the heavier cylinder undergoes larger lift force than the lighter one. The lift force and cylinder displacement always behave as an out-of-phase state. In the gap-interference region, large-amplitude oscillations could be produced extensively and in the wake-interference region, the cylinder motions and fluid flows are mainly dependent on the upstream cylinder. When the separation is large enough, both cylinders behave as two isolated ones. The mechanisms for the excitations of cylinder vibrations have also been analysed.

  14. Drug screening of whole blood by ultra-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Oiestad, Elisabeth Leere; Johansen, Unni; Oiestad, Ase Marit Leere; Christophersen, Asbjørg Solberg

    2011-06-01

    An ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method for screening of drugs in whole blood has been developed and validated. Samples were prepared by supported liquid-liquid extraction on ChemElute(®) columns with ethyl acetate/heptane (4:1). LC separation was achieved with an Acquity HSS T3-column (2.1 100 mm, 1.8-μm particle). Mass detection was performed by positive ion mode electrospray MS-MS and included the following drugs/metabolites: morphine, codeine, ethyl morphine, oxycodone, buprenorphine, methadone, cocaine, methylphenidate, amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA), Δ(9)-tetrahydrocannabinol (THC), fentanyl, alprazolam, bromazepam, clonazepam, diazepam, nordiazepam, 3-OH-diazepam, fenazepam, flunitrazepam, lorazepam, nitrazepam, oxazepam, zopiclone, zolpidem, carisoprodol, and meprobamate. The cycle time was 9 min, and within- and between-day relative coefficients of variation varied from 1% to 33% and 2% to 58%, respectively. Extraction recoveries from whole blood were > 50% except for morphine and THC. The limit of quantitation was 0.1 to 521 ng/mL, depending on the drug. PMID:21619723

  15. Integrated gas and liquid chromatography tandem mass spectrometry for forensic engine lubricating oil identification

    International Nuclear Information System (INIS)

    This paper presented a method for rapid chemical characterization of engine lubricating oils. Motor oils typically contain up to 5 per cent additives, such as detergent, antifoamant, dispersant, emulsifier, antioxidant, friction modifier, colour stabilizer and corrosion inhibitors. Different lube oil products usually have either different additives in various concentrations. As such, the formulation of additives in lube oil products should provide fingerprint information for forensic oil identification. The characterization method used in this study was based on a newly developed fast solvent liquid-liquid sample extraction procedure that combined the use of both liquid chromatography tandem mass spectrometry (LC-MS) and gas chromatography-mass spectrometry (GC-MS) simultaneously together with gas chromatography flame ionization detection (GC-FID). The method was used on a blind sample testing of commercially available engine lubricating products. The sample extraction procedure involved extraction of additives into acidified acetonitrile, two hexane washes of hydrophobic components of lube oil, filtration, and dilution with solvents for GC and LC analysis. The new method proved to be rapid and easy to use. It enabled the identification of unknown additives and hydrocarbons in many different types of fresh lube oils. Further tests will be needed to determine if this method can be used on real-world weathered samples. The method is part of an ongoing effort to deal with mysterious chemical spills, an important aspect of environmental protection and emergency preparedness. 8 refs., 7 figs

  16. Analysis of 2-methylthio-derivatives of isoprenoid cytokinins by liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tarkowski, Petr, E-mail: petr.tarkowski@upol.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Department of Biochemistry, Faculty of Science, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Vaclavikova, Katerina, E-mail: katka.vaclavik@seznam.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Department of Biochemistry, Faculty of Science, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Novak, Ondrej, E-mail: ondrej.novak@upol.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Pertry, Ine, E-mail: ine.pertry@ugent.BE [Department of Plant Biotechnology and Genetics, Ghent University, K.L.Ledeganckstraat 35, B-9000 Gent (Belgium); Hanus, Jan, E-mail: helehan@seznam.cz [Isotope Laboratory, Institute of Experimental Botany ASCR, Videnska 1083, 142 20 Prague (Czech Republic); Whenham, Robert [Apex Organics, Devon, England (United Kingdom); Vereecke, Danny, E-mail: danny.vereecke@hogent.BE [Department of Plant Production, University College Ghent, Ghent University, Schoonmeersstraat 52, B-9000 Gent (Belgium); Sebela, Marek, E-mail: marek.sebela@upol.cz [Department of Biochemistry, Faculty of Science, Palacky University, Slechtitelu 11, 783 71 Olomouc (Czech Republic); Strnad, Miroslav, E-mail: miroslav.strnad@upol.cz [Laboratory of Growth Regulators, Palacky University and Institute of Experimental Botany ASCR, Slechtitelu 11, 783 71 Olomouc (Czech Republic)

    2010-11-08

    A sensitive and reliable high-performance liquid chromatographic method with tandem mass spectrometric detection has been developed and used for the determination of 2-methylthio-cytokinin derivatives produced by the phytopathogenic actinomycete Rhodococcus fascians. The cultivation medium containing secreted cytokinins was concentrated and subjected to a solid-phase extraction (C18 and ion-exchange). The purified samples were further separated and analyzed by HPLC-ESI-MS/MS. This allowed to achieve chromatographic resolution of six highly hydrophobic cytokinin species including 2-methylthio-isopentenyladenine, 2-methylthio-isopentenyladenosine, 2-methylthio-trans-zeatin and 2-methylthio-trans-zeatin riboside and their cis-isomers when a reversed-phase chromatographic column (C4) and a mobile phase consisting of acetonitrile and 20 mM ammonium formate, pH 5, were used. Quantification was performed by a standard isotope dilution method using a multiple-reaction monitoring (MRM) mode. In the MRM mode, limits of detection reached 20-30 fmol and linear ranges spanned four orders of magnitude. Recovery values were between 35% and 65% and the analytical accuracy between 95% and 149%. The proposed bioanalytical method, which takes advantage of effective chromatographic separation of six 2-methyltio-derivatives (including isomers of zeatin-type cytokinins) and sensitive mass spectrometric detection, may become useful for plant biologists studying the significance of these substances in plant-microbe interactions.

  17. Liquid chromatography-tandem mass spectrometry for analysis of intestinal permeability of loperamide in physiological buffer.

    Directory of Open Access Journals (Sweden)

    Miriam S Rubelt

    Full Text Available Analysis of in vitro samples with high salt concentrations represents a major challenge for fast and specific quantification with liquid chromatography-tandem mass spectrometry (LC-MS/MS. To investigate the intestinal permeability of opioids in vitro employing the Ussing chamber technique, we developed and validated a fast, sensitive and selective method based on LC-MS/MS for the determination of loperamide in HEPES-buffered Ringer's solution. Chromatographic separation was achieved with an Atlantis dC18 column, 2.1 mm×20 mm, 3 µm particle size and a gradient consisting of methanol/0.1% formic acid and ammonium acetate. The flow rate was 0.7 ml/min, and the total run time was 3 min. For quantification, two mass transitions for loperamide and a deuterated internal standard (methadone-d(3 were used. The lower limit of loperamide quantification was 0.2 ng/ml. This new LC-MS/MS method can be used for the detection of loperamide in any experimental setup using HEPES-buffered Ringer's solution as a matrix compound.

  18. Determination of doxepin and desmethyldoxepin in human plasma using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Badenhorst, D; Sutherland, F C; de Jager, A D; Scanes, T; Hundt, H K; Swart, K J; Hundt, A F

    2000-05-26

    A sensitive method for the simultaneous determination of doxepin and its active metabolite desmethyldoxepin in plasma was established, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The samples were extracted with hexane-isoamyl alcohol, separated on a Phenomenex Luna C18 5 microm, 150x2.1 mm column with a mobile phase consisting of methanol-water-formic acid (600:400:0.5, v/v) at a flow-rate of 0.25 ml/min. Detection was achieved by a Perkin-Elmer API 2000 mass spectrometer at unit resolution in multiple reaction monitoring mode monitoring the transition of the protonated molecular ions m/z 280.2, 266.2 and 250.1 to the product ions m/z 107.1, 107.1 and 191.0 for analyte, metabolite and internal standard (benzoctamine-HCl), respectively. TurbolonSpray ionisation was used for ion production. The mean recovery for doxepin and desmethyldoxepin was 90% and 75%, respectively, with a lower limit of quantification at 0.320 ng/ml and 0.178 ng/ml for the analyte and its metabolite, respectively, using 0.5 ml plasma for extraction. This is the first assay method described for the simultaneous determination of doxepin and desmethyldoxepin in plasma using LC-MS-MS. The method is sensitive enough to be used in drug bioavailability studies with doxepin.

  19. Quantitative analysis of phenibut in rat brain tissue extracts by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Grinberga, Solveiga; Zvejniece, Liga; Liepinsh, Edgars; Dambrova, Maija; Pugovics, Osvalds

    2008-12-01

    Phenibut (3-phenyl-4-aminobutyric acid) is a gamma-aminobutyric acid mimetic drug, which is used clinically as a mood elevator and tranquilizer. In the present work, a rapid, selective and sensitive liquid chromatography-tandem mass spectrometry method for quantification of phenibut in biological matrices has been developed. The method is based on protein precipitation with acidic acetonitrile followed by isocratic chromatographic separation using acetonitrile-formic acid (0.1% in water; 8:92, v/v) mobile phase on a reversed-phase column. Detection of the analyte was performed by electrospray ionization mass spectrometry in multiple reaction monitoring mode with the precursor-to-product ion transition m/z 180.3 --> m/z 117.2. The calibration curve was linear over the concentration range 50-2000 ng/mL. The lower limit of quantification for phenibut in rat brain extracts was 50 ng/mL. Acceptable precision and accuracy were obtained over the whole concentration range. The validated method was successfully applied in a pharmacological study to analyze phenibut concentration in rat brain tissue extract samples. PMID:19034959

  20. Modeling protein tandem mass spectrometry data with an extended linear regression strategy.

    Science.gov (United States)

    Liu, Han; Bonner, Anthony J; Emili, Andrew

    2004-01-01

    Tandem mass spectrometry (MS/MS) has emerged as a cornerstone of proteomics owing in part to robust spectral interpretation algorithm. The intensity patterns presented in mass spectra are useful information for identification of peptides and proteins. However, widely used algorithms can not predicate the peak intensity patterns exactly. We have developed a systematic analytical approach based on a family of extended regression models, which permits routine, large scale protein expression profile modeling. By proving an important technical result that the regression coefficient vector is just the eigenvector corresponding to the least eigenvalue of a space transformed version of the original data, this extended regression problem can be reduced to a SVD decomposition problem, thus gain the robustness and efficiency. To evaluate the performance of our model, from 60,960 spectra, we chose 2,859 with high confidence, non redundant matches as training data, based on this specific problem, we derived some measurements of goodness of fit to show that our modeling method is reasonable. The issues of overfitting and underfitting are also discussed. This extended regression strategy therefore offers an effective and efficient framework for in-depth investigation of complex mammalian proteomes. PMID:17270923

  1. Electrospray-assisted laser desorption/ionization and tandem mass spectrometry of peptides and proteins.

    Science.gov (United States)

    Peng, Ivory X; Shiea, Jentaie; Ogorzalek Loo, Rachel R; Loo, Joseph A

    2007-01-01

    We have constructed an electrospray-assisted laser desorption/ionization (ELDI) source which utilizes a nitrogen laser pulse to desorb intact molecules from matrix-containing sample solution droplets, followed by electrospray ionization (ESI) post-ionization. The ELDI source is coupled to a quadrupole ion trap mass spectrometer and allows sampling under ambient conditions. Preliminary data showed that ELDI produces ESI-like multiply charged peptides and proteins up to 29 kDa carbonic anhydrase and 66 kDa bovine albumin from single-protein solutions, as well as from complex digest mixtures. The generated multiply charged polypeptides enable efficient tandem mass spectrometric (MS/MS)-based peptide sequencing. ELDI-MS/MS of protein digests and small intact proteins was performed both by collisionally activated dissociation (CAD) and by nozzle-skimmer dissociation (NSD). ELDI-MS/MS may be a useful tool for protein sequencing analysis and top-down proteomics study, and may complement matrix-assisted laser desorption/ionization (MALDI)-based measurements. PMID:17639579

  2. Analysis of aristolochic acids, aristololactams and their analogues using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Yu, Jie; Ma, Chao-Mei; Wang, Xuan; Shang, Ming-Ying; Hattori, Masao; Xu, Feng; Jing, Yu; Dong, Shi-Wen; Xu, Yu-Qiong; Zhang, Cui-Ying; Cai, Shao-Qing

    2016-08-01

    More than 80 aristolochic acids (AAs) and aristololactams (ALs) have been found in plants of the Aristolochiaceae family, but relatively few have been fully studied. The present study aimed at developing and validating a liquid chromatography tandem mass spectrometry (LC/MS(n)) for the analysis of these compounds. We characterized the fragmentation behaviors of 31 AAs, ALs, and their analogues via high performance liquid chromatography coupled with electrospray ionization mass spectrometry. We summarized their fragmentation rules and used these rules to identify the constituents contained in Aristolochia contorta, Ar. debilis, Ar. manshurensis, Ar. fangchi, Ar. cinnabarina, and Ar. mollissima. The AAs and ALs showed very different MS behaviors. In MS(1) of AAs, the characteristic pseudomolecular ions were [M + NH4](+), [M + H](+), and [M + H - H2O](+). However, only [M + H](+) was found in the MS(1) of ALs, which was simpler than that of AAs. Distinct MS(n)fragmentation patterns were found for AAs and ALs, showing the same skeleton among the different substituent groups. The distribution of the 31 constituents in the 6 species of Aristolochia genus was reported for the first time. 25 Analogues of AAs and ALs were detected in this genus. A hierarchical schemes and a calculating formula of the molecular formula of these nitrophenanthrene carboxylic acids and their lactams were proposed. In conclusion, this method could be applied to identification of similar unknown constituents in other plants. PMID:27608953

  3. De novo sequencing of peptides from top-down tandem mass spectra

    Energy Technology Data Exchange (ETDEWEB)

    Vyatkina, Kira; Wu, Si; Dekker, Leendert J.; vanDuijn, Martijn M.; Liu, Xiaowen; Tolic, Nikola; Dvorkin, Mikhail; Alexandrova, Sonya; Luider, Theo N.; Pasa-Tolic, Ljiljana; Pevzner, Pavel A.

    2015-09-28

    De novo sequencing of proteins and peptides is one of the most important problems in mass spectrometry-driven proteomics. A variety of methods have been developed to accomplish this task from a set of bottom-up tandem (MS/MS) mass spectra. However, a more recently emerged top-down technology, now gaining more and more popularity, opens new perspectives for protein analysis and characterization, implying a need in efficient algorithms for processing this kind of MS/MS data. Here we describe a method that allows to retrieve from a set of top-down MS/MS spectra long and accurate sequence fragments of the proteins contained in a sample. To this end, we outline a strategy for generating high-quality sequence tags from top-down spectra, and introduce the concept of a T-Bruijn graph by adapting to the case of tags the notion of an A-Bruijn graph widely used in genomics. The output of the proposed approach represents the set of amino acid strings spelled out by optimal paths in the connected components of a T-Bruijn graph. We illustrate its performance on top-down datasets acquired from carbonic anhydrase 2 (CAH2) and the Fab region of alemtuzumab.

  4. Tandem mass spectrometry in food safety assessment: the determination of phthalates in olive oil.

    Science.gov (United States)

    Cavaliere, Brunella; Macchione, Barbara; Sindona, Giovanni; Tagarelli, Antonio

    2008-09-26

    A gas chromatography-tandem mass spectrometry (GC-MS/MS) method for the detection of six phthalates in olive oil was developed. A gel permeation chromatography (GPC) clean-up step with cyclohexane:dichoromethane 7:3 as mobile phase was employed to remove the high-molecular mass species present in oil. Two ionization methodologies, i.e. electron (EI) and isobutane-chemical ionization (CI), were compared, in MS/MS mode, to achieve better analytical performances. An overall evaluation of all analytical parameters shows that the EI-MS/MS approach provides satisfactory results and is to be preferred to CI-MS/MS, at least in the case of the examined analytes. The observed accuracies, ranging from 71.7% to 112.2%, and the RSD values less than 9.7%, confirm the effectiveness of the proposed method in the assay of phthalate content in such a complex matrix as olive oil. The proposed protocol for the identification and assay of phthalates in olive oil might be of interest for the implementation of the QS (quality assurance scheme) for residue monitoring in food safety assessment.

  5. The inclusion of ADA-SCID in expanded newborn screening by tandem mass spectrometry.

    Science.gov (United States)

    la Marca, Giancarlo; Giocaliere, Elisa; Malvagia, Sabrina; Funghini, Silvia; Ombrone, Daniela; Della Bona, Maria Luisa; Canessa, Clementina; Lippi, Francesca; Romano, Francesca; Guerrini, Renzo; Resti, Massimo; Azzari, Chiara

    2014-01-01

    Severe combined immunodeficiency due to adenosine-deaminase defect (ADA-SCID) is usually deadly in childhood because of severe recurrent infections. When clinical diagnosis is done, permanent damages due to infections or metabolite accumulation are often present. Gene therapy, bone marrow transplantation or enzyme replacement therapy may be effective if started early. The aim of this study was to set-up a robust method suitable for screening with a minimized preparation process and with inexpensive running costs, for diagnosing ADA-SCID by tandem mass spectrometry. ADA-SCID satisfies all the criteria for inclusion in a newborn screening program. We describe a protocol revised to incorporate adenosine and 2-deoxyadenosine testing into an expanded newborn screening program. We assessed the effectiveness of this approach testing dried blood spots from 4 genetically confirmed early-onset and 5 delayed-onset ADA-SCID patients. Reference values were established on 50,000 healthy newborns (deoxyadenosine <0.09μmol/L, adenosine <1.61μmol/L). We also developed a second tier test to distinguish true positives from false positives and improve the positive predictive value of an initial abnormal result. In the first 18 months, the pilot project has identified a newborn with a genetically confirmed defect in adenosine deaminase (ADA) gene. The results show that the method having great simplicity, low cost and low process preparations can be fully applicable to a mass screening program.

  6. Determination of mycophenolic acid in human plasma by ultra performance liquid chromatography tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Vivek Upadhyay; Vikas Trivedi; Gaurang Shah; Manish Yadav; Pranav S. Shrivastav

    2014-01-01

    A simple, sensitive and high throughput ultra performance liquid chromatography tandem mass spectrometry method has been developed for the determination of mycophenolic acid in human plasma. The method involved simple protein precipitation of MPA along with its deuterated analog as an internal standard (IS) from 50 mL of human plasma. The chromatographic analysis was done on Acquity UPLC C18 (100mm*2.1mm,1.7mm) column under isocratic conditions using acetonitrile and 10 mM ammonium formate, pH 3.00 (75:25, v/v) as the mobile phase. A triple quadrupole mass spectrometer operating in the positive ionization mode was used for quantitation. In-source conversion of mycophenolic glucuronide metabolite to the parent drug was selectively controlled by suitable optimization of cone voltage, cone gas flow and desolvation temperature. The method was validated over a wide concentration range of 15–15000 ng/mL. The mean extraction recovery for the analyte and IS was 495%. Matrix effect expressed as matrix factors ranged from 0.97 to 1.02. The method was successfully applied to support a bioequivalence study of 500 mg mycophenolate mofetil tablet in 72 healthy subjects.

  7. Dynamic Bayesian Network for Accurate Detection of Peptides from Tandem Mass Spectra.

    Science.gov (United States)

    Halloran, John T; Bilmes, Jeff A; Noble, William S

    2016-08-01

    A central problem in mass spectrometry analysis involves identifying, for each observed tandem mass spectrum, the corresponding generating peptide. We present a dynamic Bayesian network (DBN) toolkit that addresses this problem by using a machine learning approach. At the heart of this toolkit is a DBN for Rapid Identification (DRIP), which can be trained from collections of high-confidence peptide-spectrum matches (PSMs). DRIP's score function considers fragment ion matches using Gaussians rather than fixed fragment-ion tolerances and also finds the optimal alignment between the theoretical and observed spectrum by considering all possible alignments, up to a threshold that is controlled using a beam-pruning algorithm. This function not only yields state-of-the art database search accuracy but also can be used to generate features that significantly boost the performance of the Percolator postprocessor. The DRIP software is built upon a general purpose DBN toolkit (GMTK), thereby allowing a wide variety of options for user-specific inference tasks as well as facilitating easy modifications to the DRIP model in future work. DRIP is implemented in Python and C++ and is available under Apache license at http://melodi-lab.github.io/dripToolkit . PMID:27397138

  8. Preventive doping control analysis: Liquid and gas chromatography time-to-flight mass spectrometry for detection of designer steriods

    NARCIS (Netherlands)

    Georgakopoulos, C.G.; Vonaparti, A.; Stamou, M.; Kiousi, P.; Lyris, E.; Angelis, Y.S.; Tsoupras, G.; Wuest, B.; Nielen, M.W.F.; Panderi, I.; Koupparis, M.

    2007-01-01

    A new combined doping control screening method for the analysis of anabolic steroids in human urine using liquid chromatography/electrospray ionization orthogonal acceleration time-of-flight mass spectrometry (LCoaTOFMS) and gas chromatography/electron ionization orthogonal acceleration time-of-flig

  9. Analysis of perfluoroalkyl substances in cord blood by turbulent flow chromatography coupled to tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Llorca, Marta; Perez, Francisca [Department of Environmental Chemistry, IDAEA-CSIC, Barcelona (Spain); Farre, Marinella, E-mail: mfuqam@cid.csic.es [Department of Environmental Chemistry, IDAEA-CSIC, Barcelona (Spain); Agramunt, Silvia [Centre for Research in Environmental Epidemiology (CREAL), Barcelona (Spain); IMIM (Hospital del Mar Research Institute), Barcelona (Spain); Kogevinas, Manolis [Centre for Research in Environmental Epidemiology (CREAL), Barcelona (Spain); IMIM (Hospital del Mar Research Institute), Barcelona (Spain); CIBER Epidemiologia y Salud Publica (CIBERESP), Barcelona (Spain); National School of Public Health, Athens (Greece); Barcelo, Damia [Department of Environmental Chemistry, IDAEA-CSIC, Barcelona (Spain); Catalan Institute for Water Research (ICRA), Girona (Spain); King Saud University, Riyadh (Saudi Arabia)

    2012-09-01

    A fast on-line analytical method based on turbulent flow chromatography (TFC) in combination with tandem mass spectrometry has been applied for the first time for the analysis of eighteen perfluoroalkyl substances (PFASs), in cord blood. A simple and rapid sample pre-treatment was optimised consisting on protein precipitation of 100 {mu}L of sample with acetonitrile (1:1) followed by centrifugation during 10 min. The method was adapted to be sensitive enough and robust with minimum sample injection volume requirements (20 {mu}L). The optimised methodology presented method limits of detection (MLOD) between 0.031 and 0.76 {mu}g/L, detection capabilities (CC{alpha}) in the range between 0.005 and 0.99 {mu}g/L and decision limits (CC{beta}) ranging from 0.006 to 1.16 {mu}g/L. The recoveries in blank blood were calculated by spiking experiments with a mixture of 18 PFASs and established between 70 and 126% for most of compounds. Isotopic dilution was carried out for quantification of selected analytes. In-house validation of this new approach was carried out according to the requirements in the 2002/657/EC Decision. Finally the good applicability of this new approach was proved by the analysis of 60 cord blood samples from two different Mediterranean cities, Barcelona (Spain) and Heraklion (Greece). Ions perfluorohexanesulfonate (PFHxS) and perfluorooctanesulfonate (PFOS) were found at highest concentration and the more frequently compounds were PFHxS, PFOS and perfluorooctanoic acid (PFOA). The newly developed method proved to be suitable for large-scale epidemiologic studies, and to the data on PFASs exposure during pregnancy. -- Highlights: Black-Right-Pointing-Pointer An on-line method has been developed for the analysis of 18 perfluoroalkyl substances. Black-Right-Pointing-Pointer The method is based on turbulent flow chromatography tandem mass spectrometry. Black-Right-Pointing-Pointer The method was applied in 60 cord blood samples from 2 Mediterranean cities

  10. Construction of an Ultrahigh Pressure Liquid Chromatography-Tandem Mass Spectral Library of Plant Natural Products and Comparative Spectral Analyses.

    Science.gov (United States)

    Lei, Zhentian; Jing, Li; Qiu, Feng; Zhang, Hua; Huhman, David; Zhou, Zhiqin; Sumner, Lloyd W

    2015-07-21

    A plant natural product tandem mass spectral library has been constructed using authentic standards and purified compounds. Currently, the library contains 1734 tandem mass spectra for 289 compounds, with the majority (76%) of the compounds being plant phenolics such as flavonoids, isoflavonoids, and phenylpropanoids. Tandem mass spectra and chromatographic retention data were acquired on a triple quadrupole mass spectrometer coupled to an ultrahigh pressure liquid chromatograph using six different collision energies (CEs) (10-60 eV). Comparative analyses of the tandem mass spectral data revealed that the loss of ring substituents preceded the C-ring opening during the fragmentation of flavonoids and isoflavonoids. At lower CE (i.e., 10 and 20 eV), the flavonoids and isoflavonoid central ring structures typically remained intact, and fragmentation was characterized by the loss of the substituents (i.e., methyl and glycosyl groups). At higher CE, the flavonoid and isoflavonoid core ring systems underwent C-ring cleavage and/or rearrangement depending on the structure, particularly hydroxylation patterns. In-source electrochemical oxidation was observed for phenolics that had ortho-diphenol moieties (i.e., vicinal hydroxyl groups on the aromatic rings). The ortho-diphenols were oxidized to ortho-quinones, yielding an intensive and, in most cases, a base ion peak corresponding to a [(M - 2H) - H](-) ion in their mass spectra. The library also contains reverse-phase retention times, allowing for the construction, validation, and testing of an artificial neural network retention prediction of other flavonoids and isoflavonoids not contained within the library. The library is freely available for nonprofit, academic use and it can be downloaded at http://www.noble.org/apps/Scientific/WebDownloadManager/DownloadArea.aspx.

  11. Characterization of N-Succinylation of L-Lysylphosphatidylglycerol in Bacillus subtilis Using Tandem Mass Spectrometry

    Science.gov (United States)

    Atila, Metin; Katselis, George; Chumala, Paulos; Luo, Yu

    2016-08-01

    Phospholipids generally dominate in bacterial lipids. The negatively charged nature of phospholipids renders bacteria susceptible to cationic antibiotic peptides. In comparison with Gram-negative bacteria, Gram-positive bacteria in general have much less zwitterionic phosphatidylethanolamine. However, they are known for producing aminoacylated phosphatidylglycerol (PG), especially positively charged uc(l)-lysyl-PG, which is catalyzed by lysyl-PG synthase MprF, which appears to have a broad range of specificity for uc(l)-aminoacyl transfer RNAs. In addition, many Gram-positive bacteria also have a dlt-gene-coded uc(d)-alanylation pathway for lipoteichoic acids and wall teichoic acids covalently attached to a glycolipid or peptidoglycan. uc(d)-Alanylation also masks the dominant negative charge of the phosphate-rich polymers of teichoic acids. Using mass spectrometry, we have recently observed that precursor scans in negative mode for deprotonated amino acid fragments were most sensitive for ester-linked amino acids. Such a scan for precursors generating an m/z 145 lysyl anion revealed lysyl-PG as well as an additional species 100 m/z units greater than lysyl-PG. This unexpected species corresponded precisely to the expected mass of N-succinylated lysyl-PG. Tandem mass spectrometry revealed a precise match to the fragmentation pattern of this putative new species. PG, lysyl-PG, and N-succinyl-lysyl-PG may form a complete loop of charge reversal from -1 to +1 and then back to -1. Analogous charge reversal by N-succinylation of lysine residues in the bacterial as well as eukaryotic proteomes has been recently discovered as a major posttranslational modification. Such modification in bacterial lipids is possibly catalyzed by an enzyme homologous to the enzymes that modify lysine residues in proteins.

  12. Quantitative analysis of positional isomers of triacylglycerols via electrospray ionization tandem mass spectrometry of sodiated adducts.

    Science.gov (United States)

    Herrera, Lisandra Cubero; Potvin, Michael A; Melanson, Jeremy E

    2010-09-01

    Herein we report a reversed-phase high-performance liquid chromatography tandem mass spectrometry (RP-HPLC/MS/MS) method for the analysis of positional isomers of triacylglycerols (TAGs) in vegetable oils. The fragmentation behavior of [M + X](+) ions (X = NH(4), Li, Na or Ag) was studied on a quadrupole-time-of-flight (Q-TOF) mass spectrometer under low-energy collision-induced dissociation (CID) conditions. Mass spectra that were dependent on the X(+) ion and the nature and position of the acyl substituents were observed for four pairs of 'AAB/ABA'-type TAGs, namely PPO/POP, OOP/OPO, LLO/LOL and OOL/OLO (where P is 16:0, palmitic acid; O is 18:1, oleic acid; and L is 18:2, linoleic acid). For the majority of [M + X](+) adducts, the loss of the fatty acid in the outer positions (sn-1 or sn-3) was favored over the loss in the central position (sn-2), which enabled the determination of the fractional abundance of the isomers. Ratios of the intensity of fragment ions at various AAB/ABA compositions produced linear calibration curves with positive slopes, comparable to those obtained traditionally by ESI-MS/MS of [M + NH(4)](+) adducts. The only exceptions were the [M + Ag](+) adducts of the PPO/POP system, which produced calibration curves with negative slopes. Sodium adducts provided the most consistent level of isomeric discrimination for the TAGs studied and also offered the most convenience in that they required no additive to the mobile phase. Therefore, calibration curve data derived from [M + Na](+) adducts were applied to the quantification of TAG regioisomers in sunflower and olive oils. The regiospecific analysis showed that palmitic acid was typically located at positions sn-1 or sn-3, whereas unsaturated fatty acids, oleic and linoleic acids were mostly found at the sn-2 position. PMID:20814981

  13. Development of a high-performance liquid chromatography - Tandem mass spectrometry urinary pterinomics workflow.

    Science.gov (United States)

    Burton, Casey; Shi, Honglan; Ma, Yinfa

    2016-07-13

    Pteridines have evoked considerable interest from the scientific community owing to their prominent roles in human health and disease. The availability of analytical methodologies suitable for comprehensive pteridine profiling, termed here as "pterinomics", has been limited by inconsistent sample preparation and the exclusion of lesser studied pteridine derivatives. In response, the present study describes a new pterinomics workflow using a high-performance liquid chromatography - tandem mass spectrometry (HPLC-MS/MS) methodology for the simultaneous analysis of 15 pteridine derivatives including four structural isomers, marking the largest quantitative pteridine panel that has been studied to-date. The validated method possessed excellent sensitivity with method detection limits (0.025 μg L(-1) to 0.5 μg L(-1)) that were comparable or superior to existing techniques. Spiked recovery studies demonstrated the technique was both accurate (88-112%) and precise (RSD: 0-6%). A comparative study of commonly used oxidative pretreatments, including triiodide, permanganate, and manganese dioxide, revealed that the oxidative mechanisms were inefficient, complex, and concentration dependent. Finally, 50 clinical urine specimens were examined with the new technique wherein 10 pteridine derivatives were quantified and population ranges have been given. This technique can be used to examine pteridine molecular epidemiology and biochemistry to support related research applications, and may further be readily extended to include additional pteridine derivatives and biological matrices for specific applications. PMID:27237839

  14. [Determination of gossypol in edible vegetable oil with high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Zhang, Wenhua; Huang, Chaoqun; Xie, Wen; Shen, Li

    2014-06-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of gossypol in edible vegetable oil. The sample was extracted with ethyl alcohol by vortex-excited oscillation. The extract was cleaned up by 0.22 microm filter membrane and centrifuged for 5 min at 4 000 r/min after standing in a fridge at 4 degrees C for 30 min. The compound was separated on a C18 column (100 mm x 2.1 mm, 3.5 microm) with acetonitrile and 1% (v/v) formic acid aqueous solution as mobile phase. The detection of gossypol was carried out by LC-MS/MS with positive electrospray ionization under multiple reaction monitoring (MRM) mode using external standard method. The limits of quantification (S/N > 10) of gossypol in edible vegetable oil was 1 mg/kg. The recoveries were from 87.4% to 100% at the spiked levels of 1, 2, 200 mg/kg of gossypol in edible vegetable oil with the relative standard deviations (RSDs) between 3.9% and 12.2%. The method, with high sensitivity, good precision and high recovery, was suitable for the confirmation and quantification of gossypol residue in edible vegetable oil. PMID:25269254

  15. Differentiating Isobaric Steroid Hormone Metabolites Using Multi-Stage Tandem Mass Spectrometry

    Science.gov (United States)

    Tedmon, Lauren; Barnes, Jeremy S.; Nguyen, Hien P.; Schug, Kevin A.

    2013-03-01

    Steroid hormones and their metabolites are currently undergoing clinical trials as potential therapeutics for traumatic brain injury (TBI). To support this work, it is necessary to develop improved procedures for differentiating isobaric species in this compound class. Equilin sulfate (E-S), estrone sulfate (E1-S), 17α-dihydroequilin sulfate (ADHE-S), and 17β-dihydroequilin sulfate (BDHE-S) are primary constituents in hormone replacement therapies, such as Premarin, which are among pharmaceuticals being investigated for TBI treatment. The latter three compounds are isomers and can be difficult to differentiate in trace analytical determinations. In this work, a systematic study of the fragmentation of ADHE-S, BDHE-S, E1-S, and E-S under different stages of higher order tandem mass spectrometry (MSn) and variation of collision energy, allowed optimization of conditions for distinguishing the isomeric structures. For epimeric variants (e.g., ADHE-S versus BDHE-S; α- versus β-stereoisomerization in the C-17 position), differentiation was achieved at MS4 and fragmentation was demonstrated through MS5. Computational analysis was performed to further explore differences in the fragmentation pathways due to changes in stereochemistry.

  16. Analysis of plant nucleotide sugars by hydrophilic interaction liquid chromatography and tandem mass spectrometry.

    Science.gov (United States)

    Ito, Jun; Herter, Thomas; Baidoo, Edward E K; Lao, Jeemeng; Vega-Sánchez, Miguel E; Michelle Smith-Moritz, A; Adams, Paul D; Keasling, Jay D; Usadel, Björn; Petzold, Christopher J; Heazlewood, Joshua L

    2014-03-01

    Understanding the intricate metabolic processes involved in plant cell wall biosynthesis is limited by difficulties in performing sensitive quantification of many involved compounds. Hydrophilic interaction liquid chromatography is a useful technique for the analysis of hydrophilic metabolites from complex biological extracts and forms the basis of this method to quantify plant cell wall precursors. A zwitterionic silica-based stationary phase has been used to separate hydrophilic nucleotide sugars involved in cell wall biosynthesis from milligram amounts of leaf tissue. A tandem mass spectrometry operating in selected reaction monitoring mode was used to quantify nucleotide sugars. This method was highly repeatable and quantified 12 nucleotide sugars at low femtomole quantities, with linear responses up to four orders of magnitude to several 100pmol. The method was also successfully applied to the analysis of purified leaf extracts from two model plant species with variations in their cell wall sugar compositions and indicated significant differences in the levels of 6 out of 12 nucleotide sugars. The plant nucleotide sugar extraction procedure was demonstrated to have good recovery rates with minimal matrix effects. The approach results in a significant improvement in sensitivity when applied to plant samples over currently employed techniques.

  17. Multiresidue Analysis of Pesticides in Straw Roughage by Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Zhang, Zihao; Feng, Mengyuan; Zhu, Kechen; Han, Lijun; Sapozhnikova, Yelena; Lehotay, Steven J

    2016-08-10

    A multiresidue analytical method using a modification of the "quick, easy, cheap, effective, rugged, and safe" (QuEChERS) sample preparation approach combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis was established and validated for the rapid determination of 69 pesticides at different levels (1-100 ng/g) in wheat and rice straws. In the quantitative analysis, the recoveries ranged from 70 to 120%, and consistent RSDs ≤ 20% were achieved for most of the target analytes (53 pesticides in wheat straw and 58 in rice straw). Almost all of the analytes achieved good linearity with R(2) > 0.98, and the limit of validation levels (LVLs) for diverse pesticides ranged from 1 to 10 ng/g. Different extraction and cleanup conditions were evaluated in both types of straw, leading to different options. The use of 0.1% formic acid or not in extraction with acetonitrile yielded similar final outcomes, but led to the use of a different sorbent in dispersive solid-phase extraction. Both options are efficient and useful for the multiresidue analysis of targeted pesticides in wheat and rice straw samples. PMID:26881844

  18. A rapid quantitative method of carisoprodol and meprobamate by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Essler, Shannon; Bruns, Kerry; Frontz, Michael; McCutcheon, J Rod

    2012-11-01

    The identification and quantitation of carisoprodol (Soma) and its chief metabolite meprobamate, which is also a clinically prescribed drug, remains a challenge for forensic toxicology laboratories. Carisoprodol and meprobamate are notable for their widespread use as muscle relaxants and their frequent identification in the blood of impaired drivers. Routine screening is possible in both an acidic/neutral pH screen and a traditional basic screen. An improvement in directed testing quantitations was desirable over the current options of an underivatized acidic/neutral extraction or a basic screen, neither of which used ideal internal standards. A new method was developed that utilized a simple protein precipitation, deuterated internal standards and a short 2-min isocratic liquid chromatography separation, followed by multiple reaction monitoring with tandem mass spectrometry. The linear quantitative range for carisoprodol was determined to be 1-35mg/L and for meprobamate was 0.5-50mg/L. The method was validated for specificity and selectivity, matrix effects, and accuracy and precision. PMID:23040985

  19. Pharmacokinetic studies of novel berberine derivatives with ultra-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Wang, Wenchao; Shen, Qin; Liang, Hui; Hua, Changlong; Liu, Yuhui; Li, Fengzhi; Li, Qingyong

    2016-09-15

    An ultra-performance liquid chromatography with tandem mass spectrometric detection method was developed for the detection of berberine and its derivatives (A4, B4) in rat plasma and other organs. This validated method was successfully applied to our pharmacokinetic study of BBR derivatives in rats. At the same dose of administration, the Cmax of B4 was about eight times higher than BBR, and its half-life was approximately two times longer than BBR, according to the bigger areas under plasma concentration curves. Inversely, the pharmacokinetic parameter levels of A4 were all inferior to BBR, suggesting a tight structure-activity relationship of these compounds. Small dose of parenteral administration was used for the study of absolute oral bioavailability of A4, B4, and BBR, and the results calculated were 0.12%, 3.4% and 0.7%, respectively. The accumulations of B4 among all organs were intestine>liver>heart>kidney>lung>spleen>plasma, proving a deeply targeting property of B4, which met our experimental assumption. Together, the experimental results proved that compared with BBR and A4, the derivative B4 had higher absolute oral bioavailability and the ability of deeply targeting so that can be likely used in some organ-targeted diseases. PMID:27494281

  20. Global Analysis of the Membrane Subproteome of Pseudomonas aeruginosa using Liquid Chromatography-Tandem Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Blonder, Josip; Goshe, Michael B.; Xiao, Wenzhong; Camp, David G.; Wingerd, Mark A.; Davis, Ronald W.; Smith, Richard D.

    2004-05-30

    Pseudomonas aeruginosa is one of the most significant opportunistic bacterial pathogens in humans causing infections and premature death in patients with cystic fibrosis, AIDS, severe burns, organ transplants or cancer. Liquid chromatography coupled online with tandem mass spectrometry (LC-MS/MS) was used for the large-scale proteomic analysis of the P. aeruginosa membrane subproteome. Concomitantly, an affinity labeling technique, using iodoacetyl-PEO biotin to tag cysteinyl-containing proteins, permitted the enrichment and detection of lower abundance membrane proteins. The application of these approaches resulted in the identification of 786 proteins. A total of 333 proteins (42%) had a minimum of one transmembrane domain (TMD; ranging from 1 to 14) and 195 proteins were classified as hydrophobic based on their positive GRAVY values (ranging from 0.01 to 1.32). Key integral inner and outer membrane proteins involved in adaptation and antibiotic resistance were conclusively identified, including the detection of 53% of all predicted opr-type porins (outer integral membrane proteins) and all the components of the mexA-mexB-oprM transmembrane protein complex. This work represents the most comprehensive qualitative proteomic analysis of the membrane subproteome of P. aeruginosa and for prokaryotes in general to date.

  1. Effective Leveraging of Targeted Search Spaces for Improving Peptide Identification in Tandem Mass Spectrometry Based Proteomics.

    Science.gov (United States)

    Shanmugam, Avinash K; Nesvizhskii, Alexey I

    2015-12-01

    In shotgun proteomics, peptides are typically identified using database searching, which involves scoring acquired tandem mass spectra against peptides derived from standard protein sequence databases such as Uniprot, Refseq, or Ensembl. In this strategy, the sensitivity of peptide identification is known to be affected by the size of the search space. Therefore, creating a targeted sequence database containing only peptides likely to be present in the analyzed sample can be a useful technique for improving the sensitivity of peptide identification. In this study, we describe how targeted peptide databases can be created based on the frequency of identification in the global proteome machine database (GPMDB), the largest publicly available repository of peptide and protein identification data. We demonstrate that targeted peptide databases can be easily integrated into existing proteome analysis workflows and describe a computational strategy for minimizing any loss of peptide identifications arising from potential search space incompleteness in the targeted search spaces. We demonstrate the performance of our workflow using several data sets of varying size and sample complexity. PMID:26569054

  2. Validation of salivary cortisol and testosterone assays in chimpanzees by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kutsukake, Nobuyuki; Ikeda, Koki; Honma, Seijiro; Teramoto, Migaku; Mori, Yusuke; Hayasaka, Ikuo; Yamamoto, Rain; Ishida, Takafumi; Yoshikawa, Yasuhiro; Hasegawa, Toshikazu

    2009-08-01

    Owing to its high temporal sensitivity, saliva has distinct advantages for measuring steroids, compared with other noninvasive samples such as urine and feces. Here, we report the validity of assaying salivary cortisol (C) and testosterone (T) using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in captive male chimpanzees, Pan troglodytes. For both the C and T concentrations, we found positive relationships between saliva and plasma. The concentrations of C and T in saliva showed clear patterns of diurnal fluctuation, whereas those in urine and feces did not. These results suggest that the salivary steroid concentrations can be regarded as good indicators of circulating steroid levels. We also developed and validated an efficient method for collecting saliva samples from cotton rope. Although rope includes inherent steroid-like compounds and may affect the accuracy of steroid measurements, our rope-washing procedures effectively removed intrinsic steroidal materials. There was a significant association between the C and T concentrations measured from saliva collected from rope licked by the chimpanzees and those measured from saliva collected directly from the mouth. Salivary T values estimated by LC/MS-MS were similar to those measured by radioimmunoassay. The results indicate the usefulness of saliva as a noninvasive steroid measure and that steroids in the saliva of chimpanzees can be accurately measured by LC-MS/MS.

  3. A method for profiling gangliosides in animal tissues using electrospray ionization-tandem mass spectrometry.

    Science.gov (United States)

    Tsui, Zhao-Chun; Chen, Qi-Rui; Thomas, Michael J; Samuel, Michael; Cui, Zheng

    2005-06-15

    Gangliosides are critical in many functions of mammalian cells but present as a minor lipid component with many molecular species of subtle differences. Conventional strategies for profiling gangliosides suffer from poor reproducibility, low sensitivity, and low-throughput capacity. Prior separation of gangliosides by thin-layer chromatography and/or high-performance liquid chromatography not only was laborious and tedious but also could introduce uneven losses of molecular species. We developed a new strategy of using electrospray ionization-tandem mass spectrometry (ESI-MS/MS) to profile gangliosides with high-throughput potential. This strategy involves three new findings: (i) collision-induced fragmentation of gangliosides gave rise to a common ion of m/z 290, a derivative of N-acetylneuraminic acid; (ii) phospholipids exert a profound suppression of ganglioside detection in ESI-MS/MS to prevent a direct detection in total cellular lipid extracts; and (iii) enrichment of gangliosides in the aqueous phase from total cellular lipid extracts eliminates the damping effect of phospholipids and permits direct precursor scan. PMID:15907870

  4. Metabolism profiles of nuciferine in rats using ultrafast liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Ye, Lin-Hu; Xiao, Bing-Xin; Liao, Yong-Hong; Liu, Xin-Min; Pan, Rui-Le; Chang, Qi

    2016-08-01

    Nuciferine (NF) is one of the main aporphine alkaloids existing in the traditional Chinese medicine Folium Nelumbinis (lotus leaves). Modern pharmacological studies have demonstrated that NF has a broad spectrum of bioactivities, such as anti-HIV and anti-hyperlipidemic effects, and has been recommended as a leading compound for new drug development. However, the metabolites and biotransformation pathway of NF in vivo have not yet been comprehensively investigated. The present study was performed to identify the metabolites of NF for exploring in vivo fates. Rat plasma and urine samples were collected after oral administration and prepared by liquid-liquid extraction with ethyl acetate. A method based on ultrafast liquid chromatography with tandem mass spectrometry was applied to identify the metabolites. Q1 (first quadrupole) full scan combined with a multiple reaction monitoring (MRM) survey scan were used for the detection of metabolites. MRM-information-dependent acquisition of enhanced product ions was used for the structural identification of detected metabolites. A total of 10 metabolites were identified, including phase I (demethylation, oxidation and dehydrogenation) and phase II (glucuronidation, sulfation and glutathione) biotransformation products. Demethylation is the main metabolic pathway of NF in the body. These results can help in improving understanding of the disposition and pharmacological mechanism of NF in the body. Copyright © 2016 John Wiley & Sons, Ltd. PMID:26682724

  5. Selective extraction and determination of neonicotinoid insecticides in wine by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Rodríguez-Cabo, T; Casado, J; Rodríguez, I; Ramil, M; Cela, R

    2016-08-19

    A simplified, high throughput procedure for the determination of five neonicotinoid insecticides in red and white wines, using liquid chromatography (LC)-tandem mass spectrometry (MS/MS), is presented. The effects of different experimental parameters (extraction sorbent, solvent elution and clean-up conditions) in the efficiency and the selectivity of the sample preparation process were assessed through calculation of the extraction yields and the matrix effects (MEs). Wines (10mL) were concentrated using OASIS HLB cartridges, on-line connected to Florisil clean-up cartridges, with acetonitrile serving as the elution solvent. The extract (5mLvol) was concentrated to 1mL and injected in the LC-ESI-MS/MS system. The optimized procedure provided quantitative extraction yields at the same time that the efficiency of ESI ionization remained unchanged between standards and sample extracts. Overall recoveries, calculated against authentic standards in ACN, varied between 77 and 119% and the attained limits of quantification remained below 0.2ngmL(-1). Analysis of commercial wines revealed imidacloprid residues in more than 50% of processed samples, with a maximum level of 14ngmL(-1). PMID:27425763

  6. Tandem mass spectrometry in metallomics and the involving role of ICP-MS detection: a review.

    Science.gov (United States)

    Vogiatzis, C G; Zachariadis, G A

    2014-03-28

    Metallomics is a relatively new branch of omics with a growing interest. The study of metallomes is becoming more focused in certain metabolites and the screening of various categories of analytes using a robust analytical methodology is more than appealing. In this context, when dealing with the challenge of identifying a certain species or specify a particular molecular structure, tandem mass spectrometry (MS/MS) is a reliable tool. Moreover, MS/MS instrumentation is recommended in hyphenated chromatographic techniques with MS detection such as LC-MS, where primary molecular species suffer minor fragmentation (soft-ionization techniques). ICP-MS is widely used in metallomics with its main advantages being the provided high sensitivity and selectivity. Usually, analyzes utilize ICP-MS as the main detection. Its role in proteomics is significant as an alternating choice for protein and peptide quantifications. In this review, we discuss modern trends and applications of MS/MS in the important and growing field of metallomics. These reports concern the identification, characterization and determination of various metal species such as metalloproteins, metallo-DNA adducts, metal-labeled molecules and other metal binding biomolecules. Such assays also present new and interesting hyphenated instrumentation and novel sophisticated apparatus. In addition, we designate the role of ICP-MS in the mentioned contributions and in the same scope we highlight some general analytical strategies.

  7. Development of a dedicated peptide tandem mass spectral library for conservation science.

    Science.gov (United States)

    Fremout, Wim; Dhaenens, Maarten; Saverwyns, Steven; Sanyova, Jana; Vandenabeele, Peter; Deforce, Dieter; Moens, Luc

    2012-05-30

    In recent years, the use of liquid chromatography tandem mass spectrometry (LC-MS/MS) on tryptic digests of cultural heritage objects has attracted much attention. It allows for unambiguous identification of peptides and proteins, and even in complex mixtures species-specific identification becomes feasible with minimal sample consumption. Determination of the peptides is commonly based on theoretical cleavage of known protein sequences and on comparison of the expected peptide fragments with those found in the MS/MS spectra. In this approach, complex computer programs, such as Mascot, perform well identifying known proteins, but fail when protein sequences are unknown or incomplete. Often, when trying to distinguish evolutionarily well preserved collagens of different species, Mascot lacks the required specificity. Complementary and often more accurate information on the proteins can be obtained using a reference library of MS/MS spectra of species-specific peptides. Therefore, a library dedicated to various sources of proteins in works of art was set up, with an initial focus on collagen rich materials. This paper discusses the construction and the advantages of this spectral library for conservation science, and its application on a number of samples from historical works of art.

  8. Measurement of phthalates diesters in food using gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Cariou, Ronan; Larvor, Frédéric; Monteau, Fabrice; Marchand, Philippe; Bichon, Emmanuelle; Dervilly-Pinel, Gaud; Antignac, Jean-Philippe; Le Bizec, Bruno

    2016-04-01

    An analytical strategy dedicated to 4 major phthalate diesters (DiBP, DnBP, BBzP and DEHP) monitoring in food items has been developed and validated according to normalized guidelines. The method has been applied to a wide range of foodstuffs (n=54) to generate first-ever occurrence data at the French level. This method involves separation and detection using gas chromatography coupled to tandem mass spectrometry, in electron ionisation with highly specific selected reaction monitoring, quantification being performed according to the isotope dilution principle. A particular attention has been paid to background contamination management at any stage of the analytical process, from the sampling to the expression of the results. Limits of reporting, defined as statistically different from background contamination, were found to be 2.7, 0.53, 0.18 and 3.4 μg kg(-1), and relative combined uncertainties were finally found to be 7.6%, 12.2%, 12.0% and 14.1%, for DiBP, DnBP, BBzP and DEHP, respectively.

  9. Identification of Microorganisms by High Resolution Tandem Mass Spectrometry with Accurate Statistical Significance

    Science.gov (United States)

    Alves, Gelio; Wang, Guanghui; Ogurtsov, Aleksey Y.; Drake, Steven K.; Gucek, Marjan; Suffredini, Anthony F.; Sacks, David B.; Yu, Yi-Kuo

    2016-02-01

    Correct and rapid identification of microorganisms is the key to the success of many important applications in health and safety, including, but not limited to, infection treatment, food safety, and biodefense. With the advance of mass spectrometry (MS) technology, the speed of identification can be greatly improved. However, the increasing number of microbes sequenced is challenging correct microbial identification because of the large number of choices present. To properly disentangle candidate microbes, one needs to go beyond apparent morphology or simple `fingerprinting'; to correctly prioritize the candidate microbes, one needs to have accurate statistical significance in microbial identification. We meet these challenges by using peptidome profiles of microbes to better separate them and by designing an analysis method that yields accurate statistical significance. Here, we present an analysis pipeline that uses tandem MS (MS/MS) spectra for microbial identification or classification. We have demonstrated, using MS/MS data of 81 samples, each composed of a single known microorganism, that the proposed pipeline can correctly identify microorganisms at least at the genus and species levels. We have also shown that the proposed pipeline computes accurate statistical significances, i.e., E-values for identified peptides and unified E-values for identified microorganisms. The proposed analysis pipeline has been implemented in MiCId, a freely available software for Microorganism Classification and Identification. MiCId is available for download at http://www.ncbi.nlm.nih.gov/CBBresearch/Yu/downloads.html.

  10. Quantitation of Thioprolines in Grape Wine by Isotope Dilution-Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Liu, Jingjing; Meng, Xiangpeng; Chan, Wan

    2016-02-17

    Cysteine reacts with reactive carbonyls to form thioprolines, which have been demonstrated to possess various pharmaceutical properties. Therefore, thioproline formation is considered as a major detoxification pathway for carcinogenic reactive carbonyls. In this study, we report the initial identification of thiazolidine-4-carboxylic acid (1) and 2-methylthiazolidine-4-carboxylic acid (2), two very common thioprolines, formed by reacting formaldehyde and acetaldehyde with cysteine in grape wine samples. We have developed an isotope dilution-liquid chromatography-tandem mass spectrometry method featuring high sensitivity (limit of detection of ≤1.5 ng/mL) and selectivity to quantitate compounds 1 and 2. The method after validated to be highly accurate (recovery of ≥92%) and precise [intraday relative standard deviation (RSD) of ≤4.1% and interday RSD of ≤9.7%] was applied to determine the varying compound 1 and 2 contents in grape wine samples. Results revealed the grape type and storage duration-dependent formation of thioprolines in grape wines. Overall, the results are expected to facilitate compound-dependent investigations of the health benefits of grape wine, and our findings could be adopted to predict the age of grape wine.

  11. Determination of gestagens in kidney fat by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Lõhmus, Madis; Kender, Tiia

    2007-03-14

    The use of gestagens in animal fattening is prohibited within the European Union. Recently, the use of spectrometric methods for the detection and confirmation of banned substances was made obligatory. Therefore, conventional high-performance liquid chromatographic (HPLC) methods have been superseded. It has been possible to couple a previously described HPLC method for the determination of acetyl-gestagens in kidney fat to tandem mass spectrometry (LC-MS/MS). The decision limits CCalpha and the detection capability CCbeta are found to be below the minimum required performance limit (MRPL) established for medroxyprogesterone acetate (MPA) at 1 microg kg(-1). The calculated values for CCalpha are as follows: megestrol acetate (MGA)--0.15 microg kg(-1), melengesterol acetate (MLA)--0.15 microg kg(-1), chlormadinone acetate (CMA)--0.37 microg kg(-1) and for medroxyprogesterone acetate (MPA)--0.24 microg kg(-1). The CCbeta values for these compounds have been determined as 0.19, 0.19, 0.47 and 0.32 microg kg(-1), respectively. PMID:17386717

  12. [Determination of clavulanic acid residue in milk by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Yang, Gang; Huang, Xianhui; Guo, Chunna; Fang, Qiuhua; He, Limin

    2012-06-01

    An analytical method was developed for the determination of clavulanic acid (CLAV) in milk by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). A 2 g milk sample was deproteinized by ethanol. The supernatant was transferred into a pear-shaped bottle to be evaporated to about 0.5 mL, and the residue was dissolved with ammonium acetate solution. The sample was determined by HPLC-MS/MS after the purification. The chromatographic separation was achieved on a Luna 5u C8 column using 0.1% formic acid in water and acetonitrile as mobile phases with gradient elution. The identification of CLAV was carried out by MS/MS equipped with electrospray ionization in negative scanning and multiple reaction monitoring (MRM) modes. Matrix-matched calibration standard was used for the quantification. The calibration curve showed perfect linear in the range of 10 - 400 microg/kg with the correlation coefficient of 0.999. The limit of detection (LOD, S/N > or = 3) was 10 microg/kg in milk, and the limit of quantification (LOQ, S/N > or = 10) was 20 microg/kg. The mean recoveries varied from 80.00% to 91.25% at the four spiked levels of LOQ, 1/2MRL (the maximum residue limit), MRL, and 2MRL with the relative standard deviations of 5.60% -8.77%. In conclusion, the established method can be applied for the determination of CLAV residues in milk.

  13. Comprehensive characterization of anticoagulant rodenticides in sludge by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Gómez-Canela, Cristian; Lacorte, Silvia

    2016-08-01

    The occurrence of 10 commonly used anticoagulant rodenticides in centrifuged sludge of 27 wastewater treatment plants was evaluated using solid-liquid extraction (SLE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Activated carbon, alumina, and Florisil cartridges with methanol/dichloromethane as eluting solvents were tested in combination with primary-secondary amine (PSA) to optimize an efficient sample cleanup. PSA in combination with Florisil was the best methodology to extract anticoagulant rodenticides in sludge providing recoveries between 42 ± 0.5 and 100 ± 2 %. Warfarin, bromadiolone, ferulenol, and coumachlor were the most ubiquitous compounds in sludge at concentrations up to 84.2 ng g(-1) for the latter. Coumatetralyl, dicoumarol, and brodifacoum were detected sporadically at levels between 6.1 and 17.4 ng g(-1). On the contrary, acenocoumarol, difenacoum, and flocoumafen were not detected in any sample. Finally, we estimated the amount of anticoagulant rodenticides discharged via sludge in order to determine the potential impact to agricultural soil according to different sludge usage practices in the region investigated. This study demonstrates that anticoagulant rodenticides are accumulated in sludge during activated sludge treatment and that the application of sludge as fertilizers may pose a future environmental risk, if not controlled. PMID:27146526

  14. Endogenous glucocorticoid analysis by liquid chromatography-tandem mass spectrometry in routine clinical laboratories.

    Science.gov (United States)

    Hawley, James M; Keevil, Brian G

    2016-09-01

    Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a powerful analytical technique that offers exceptional selectivity and sensitivity. Used optimally, LC-MS/MS provides accurate and precise results for a wide range of analytes at concentrations that are difficult to quantitate with other methodologies. Its implementation into routine clinical biochemistry laboratories has revolutionised our ability to analyse small molecules such as glucocorticoids. Whereas immunoassays can suffer from matrix effects and cross-reactivity due to interactions with structural analogues, the selectivity offered by LC-MS/MS has largely overcome these limitations. As many clinical guidelines are now beginning to acknowledge the importance of the methodology used to provide results, the advantages associated with LC-MS/MS are gaining wider recognition. With their integral role in both the diagnosis and management of hypo- and hyperadrenal disorders, coupled with their widespread pharmacological use, the accurate measurement of glucocorticoids is fundamental to effective patient care. Here, we provide an up-to-date review of the LC-MS/MS techniques used to successfully measure endogenous glucocorticoids, particular reference is made to serum, urine and salivary cortisol. PMID:27208627

  15. Confirmatory analysis of firocoxib in bovine milk by rapid resolution liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Dowling, Geraldine; Gallo, Pasquale; Regan, Liam

    2009-02-15

    A rapid method has been developed to analyse for firocoxib (FIRO) residue in bovine milk. Milk samples were extracted with acetonitrile and sample extracts were purified on Evolute ABN solid phase extraction cartridges. Aliquots were analysed by rapid resolution liquid chromatography tandem mass spectrometry (RRLC-MS/MS). The method was validated in bovine milk, according to the criteria defined in Commission Decision 2002/657/EC. The decision limit (CCalpha) was 1.18ng/mL and for the detection capability a (CCbeta) value of 2.02ng/mL was obtained. The measurement uncertainty of the method was 27%. Fortifying bovine milk samples (n=18) in three separate assays, show the accuracy of the method to be between 96 and 105%. The precision of the method, expressed as RSD values for the within-lab reproducibility at the three levels of fortification (5, 7.5 and 10ng/mL) was less than 11% respectively. PMID:19179123

  16. Multiresidue analysis of environmental pollutants in edible vegetable oils by gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Rui-Ze; Jiang, Jie; Mao, Ting; Zhao, Ya-Song; Lu, Yong

    2016-09-15

    A novel multiresidue determination of polycyclic aromatic hydrocarbons (PAHs), phthalate esters (PAEs) and alkylphenols (APs) in edible vegetable oils was developed. The samples were extracted with hexane-saturated acetonitrile, and after concentration, the extract was directly qualitatively and quantitatively analyzed by gas chromatography-tandem mass spectrometry (GC-MS/MS) with multiple reaction monitoring (MRM) in positive ion mode. The calibration curve displayed good linearity in the range of 2-100μg/L, with correlation coefficients greater than 0.99. The mean recoveries were 70.0-110.8% by analysis of spiked oil, and the relative standard deviations (RSDs) were 2.1-10.2% (n=6), respectively. The limits of detection (LODs) for the 23 PAHs, 17 PAEs and 3 APs were 0.1-1.0μg/kg, 0.1-4.0μg/kg and 1.2-3.0μg/kg, respectively. The established method effectively avoided interference from large amounts of lipids and pigments. It was applied to real sample and shown to be a rapid and reliable alternative for determination and confirmation in routine analysis. PMID:27080878

  17. Determination of Residual Acrylamide in Medical Polyacrylamide Hydrogel by High Performance Liquid Chromatography tandem Mass Spectroscopy

    Institute of Scientific and Technical Information of China (English)

    WEI-WEI LI; HUI LI; ZHI-FEI LIU; QUN QIAO

    2009-01-01

    Objective To determine residual acrylamide in medical polyacrylamide hydrogel by high performance liquid chromatography tandem mass spectroscopy (HPLC-MS). Methods After 13C3 labeled acrylamide was added, the sample was extracted with water and then cleaned up with ExtrelutTM 20. The polyaerylamide hydrogel sample and 20 clinical cases were analyzed by HPLC-MS/MS and isotope dilution quantifying technique in selected reaction monitoring (SRM) mode. Results Acrylamide was separated from polyacrylamide hydrogel. The concentration of acrylamide in polyacrylamide hydrogel ranged from 3.9×109 to 3.1×108g/L in the 20 clinical cases. The peak area was favorable linear and the range was up to 3 000 μg/L. The recovery rate was 103.1% with a relative standard deviation (RSD) of 6.20%, when the mark level was 50 μg/L. Conclusion HPLC-MS is a rapid, accurate, and sensitive method for the determination of residual acrylamide in medical polyacrylamide hydrogel.

  18. Determination of homocitrulline in urine of patients with HHH syndrome by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Al-Dirbashi, Osama Y; Al-Hassnan, Zuhair N; Rashed, Mohamed S

    2006-12-01

    A liquid chromatography tandem mass spectrometric method is described for the analysis of homocitrulline in human urine, a key metabolite in the differential diagnosis of hyperammonemia, hyperornithinemia, homocitrullinuria (HHH) syndrome. Urine samples were prepared by mere five-fold dilution with a mixture of internal standards (2H2-citrulline and 2H3-creatinine) used for the simultaneous quantification of creatinine. Analytes were separated on a cyano column and eluted isocratically within seven min. Detection was achieved by monitoring transitions of 190 > 84 and 190 > 127 for homocitrulline, 178 > 115 for 2H2-citrulline, 114 > 44 for creatinine and 117 > 47 for 2H3-creatinine. Calibration curves were linear up to 100 micromol/L. Intraday (n = 7) and interday (n = 6) variations were less than 10%. In urine samples from three siblings confirmed to have HHH syndrome, homocitrulline levels were at 13.3 (74), 21.1 (50) and 108.2 (103) mmol/mol creatinine (micromol/L). Control values were 0-9 mmol/mol creatinine (n = 120). The current method solves specificity issues in homocitrulline determination often encountered with some ninhydrin-based systems (coelution with methionine) and some o-phthalaldehyde-based ones (coelution with taurine), and presents an attractive alternative with a relatively high throughput.

  19. [Determination of gossypol in edible vegetable oil with high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Zhang, Wenhua; Huang, Chaoqun; Xie, Wen; Shen, Li

    2014-06-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of gossypol in edible vegetable oil. The sample was extracted with ethyl alcohol by vortex-excited oscillation. The extract was cleaned up by 0.22 microm filter membrane and centrifuged for 5 min at 4 000 r/min after standing in a fridge at 4 degrees C for 30 min. The compound was separated on a C18 column (100 mm x 2.1 mm, 3.5 microm) with acetonitrile and 1% (v/v) formic acid aqueous solution as mobile phase. The detection of gossypol was carried out by LC-MS/MS with positive electrospray ionization under multiple reaction monitoring (MRM) mode using external standard method. The limits of quantification (S/N > 10) of gossypol in edible vegetable oil was 1 mg/kg. The recoveries were from 87.4% to 100% at the spiked levels of 1, 2, 200 mg/kg of gossypol in edible vegetable oil with the relative standard deviations (RSDs) between 3.9% and 12.2%. The method, with high sensitivity, good precision and high recovery, was suitable for the confirmation and quantification of gossypol residue in edible vegetable oil.

  20. Antibiotic toxicity and absorption in zebrafish using liquid chromatography-tandem mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Fan Zhang

    Full Text Available Evaluation of drug toxicity is necessary for drug safety, but in vivo drug absorption is varied; therefore, a rapid, sensitive and reliable method for measuring drugs is needed. Zebrafish are acceptable drug toxicity screening models; we used these animals with a liquid chromatography-tandem mass spectrometry (LC-MS/MS method in a multiple reaction monitoring mode to quantify drug uptake in zebrafish to better estimate drug toxicity. Analytes were recovered from zebrafish homogenate by collecting supernatant. Measurements were confirmed for drugs in the range of 10-1,000 ng/mL. Four antibiotics with different polarities were tested to explore any correlation of drug polarity, absorption, and toxicity. Zebrafish at 3 days post-fertilization (dpf absorbed more drug than those at 6 h post-fertilization (hpf, and different developmental periods appeared to be differentially sensitive to the same compound. By observing abnormal embryos and LD50 values, zebrafish embryos at 6 hpf were considered to be suitable for evaluating embryotoxicity. Also, larvae at 3 dpf were adapted to measure acute drug toxicity in adult mammals. Thus, we can exploit zebrafish to study drug toxicity and can reliably quantify drug uptake with LC-MS/MS. This approach will be helpful for future studies of toxicology in zebrafish.

  1. Newborn screening with tandem mass spectrometry: 12 months' experience in NSW Australia.

    Science.gov (United States)

    Wiley, V; Carpenter, K; Wilcken, B

    1999-12-01

    Since 1998, the NSW Newborn Screening Program has used electrospray tandem mass spectrometry (MS/MS) to analyse samples from all babies born in NSW and the ACT (approximately 95000 per year) for selected amino acids and acylcarnitines. The software rules editor initially interprets all results where ratio of analyte to internal standard is modified by input from the external standard curves per analyte. The numerical results are then downloaded to the NSW Newborn Screening database, which provides automatic, analyte specific follow-up test cascade. We have analysed samples from 137 120 consecutive newborns received by the program, requested repeat samples from 122 babies, and found abnormal levels in 17 babies with phenylketonuria, 1 tetrahydrobiopterin deficiency, 3 hyperphenylalaninaemia, 1 maple syrup urine disease, 1 tyrosinaemia type II, 1 congenital lactic acidosis, 2 medium-chain acyl CoA dehydrogenase deficiency, 1 short-chain acyl CoA dehydrogenase deficiency, 1 beta-ketothiolase deficiency, 2 vitamin B12 deficient babies of vegan mothers and 1 glutaric aciduria type I. Using population data plus that obtained from retrospective samples with proven disorders we have established cut-off levels for each analyte tested. This coupled with the ability of the database to provide ratios of various analytes gives excellent screening specificity and sensitivity for the detection of at least 40 rare inborn errors of metabolism.

  2. Elucidation of O-Phosphoryl and N-Phosphoryl Amino Acids by Electrospray Ionization Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    ZHANG,Jian-Chen(张建臣); CAO,Shu-Xiaa(曹书霞); XU,Juna(徐军); LIAO,Xin-Cheng(廖新成); ZHAO,Yu-Fen(赵玉芬)

    2004-01-01

    Mass spectroscopic characteristics of phosphoryl amino acids were studied in detail by positive and negative electrospray ionization mass spectrometry (ESI-MS) in conjunction with tandem mass spectrometry (MS/MS). Besides N-diisopropyloxyphosphoryl amino acids (N-DIPP-AA), O-phospho- and O-diisopropyloxyphosphoryl amino acids (O-DIPP-AA) were studied and compared to N-DIPP-AA. The fragmentation pathways of [M+H]+, [M+Na]+ and [M-H]- ions of phosphoryl amino acids were summarized. In addition to several similar patterns,each of them showed its characteristic fragmention.

  3. An improved method for measuring metaldehyde in surface water using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Schumacher, Melanie; Castle, Glenn; Gravell, Anthony; Mills, Graham A; Fones, Gary R

    2016-01-01

    The molluscicide metaldehyde (2,4,6,8-tetramethyl-1,3,5,7-tetraoxocanemetacetaldehyde) is an emerging pollutant. It is frequently detected in surface waters, often above the European Community Drinking Water Directive limit of 0.1 μg/L for a single pesticide. Gas chromatography mass spectrometry (GC-MS) can be used to determine metaldehyde in environmental waters, but this method requires time consuming extraction techniques prior to instrumental analysis. Use of liquid chromatography-tandem mass spectrometry (LC-MS/MS) can overcome this problem. We describe a novel LC-MS/MS method, using a methylamine mobile phase additive, coupled with on-line sample enrichment that allows for the rapid and sensitive measurement of metaldehyde in surface water. Only the methylamine adduct of metaldehyde was formed with other unwanted alkali metal adducts and dimers being suppressed. As considerably less collision energy is required to fragment the methylamine adduct, a five-fold improvement in method sensitivity, compared to a previous method using an ammonium acetate buffer mobile phase was achieved. This new approach offers: •A validated method that meets regulatory requirements for the determination of metaldehyde in surface water.•Improved reliability of quantification over existing LC-MS/MS methods by using stable precursor ions for multiple reaction monitoring.•Low limits of quantification for tap water (4 ng/L) and river water (20 ng/L) using only 800 μL of sample; recoveries > 97%. PMID:27054094

  4. Accelerator mass spectrometry of the heaviest long-lived radionuclides with a 3-MV tandem accelerator

    Indian Academy of Sciences (India)

    Christof Vockenhuber; Robin Golser; Walter Kutschera; Alfred Priller; Peter Steier; Stephan Winkler; Vitaly Liechtenstein

    2002-12-01

    A 3-MV pelletron tandem accelerator is the heart of the Vienna environmental research accelerator (VERA). The original design of the beam transport components allows the transport of ions of all elements, from the lightest to the heaviest. For light ions the suppression of neighboring masses was sufficient to measure isotopic ratios of 14C/12C and 26Al/27Al as low as 10-15 and 10Be/9Be down to 10-13. To suppress neighboring masses for the heaviest radionuclides in the energy range of 10–20 MeV, the resolution of VERA was increased both by improving the ion optics of existing elements at the injection side and by installing a new high-resolution electrostatic separator at the high-energy side. Interfering ions which pass all beam filters are identified with a Bragg-type ionization detector and a high-resolution time-of-flight system. Two ultra-thin diamond-like carbon (DLC) foils are used in the start and stop detector, which substantially reduces losses due to beam straggling. This improved set up enables us to measure even the heaviest long-lived radionuclides, where stable isobaric interferences are absent (e.g. 236U and 244Pu), down to environmental levels. Moreover, the advantage of a ‘small’ and well manageable machine like VERA lies in its higher stability and reliability which allows to measure these heavy radionuclides more accurately, and also a large number of samples.

  5. [Determination of aflatoxins in cereals and oils by liquid chromatography-triple quadrupole tandem mass spectrometry].

    Science.gov (United States)

    Wang, Xiupin; Li, Peiwu; Yang, Yang; Zhang, Wen; Zhang, Qi; Fan, Sufang; Yu, Li; Wang, Lin; Chen, Xiaomei; Li, Ying; Jiang, Jun

    2011-06-01

    The high performance liquid chromatography (HPLC)-triple quadrupole tandem mass spectrometry was applied for the determination of the aflatoxins: B1 (AFB1), B2 (AFB2), G1 (AFG1) and G2 (AFG2), in cereals and oils. The samples were first extracted by ultrasonic method. The optimized conditions of ultrasonic extraction were as follows: temperature of 50 degrees C, extraction time of 3 min, methanol-water (containing 40 g/L NaCl) (80: 20, v/v) solution as the medium and a ratio of sample to solvent of 1 : 3 (g: mL). The extracts were then purified using an immunoaffinity column. The separation was performed on a C18 column with mobile phases of 10 mmol/L ammonium acetate and methanol in gradient elution. The sensitive detection of the four AFT compounds by electrospray ionization mass spectrometry (ESI-MS) was carried out in selected reaction monitoring (SRM) mode with aflatoxin M1 (AFM1) as the internal standard. Under the optimized conditions, the limits of detection of AFB1, AFB2, AFG1 and AFG2 were 0.002, 0.004, 0.004 and 0.012 microg/kg, respectively. The recoveries of aflatoxins in different spiked cereals and oils were in the range from 87% to 111%. The intra-day and inter-day precisions were not more than 6.7% and 5.6%, respectively. In comparison with the external standard method, this method can effectively inhibit the matrix effects, and greatly improve the accuracy.

  6. [Determination of aflatoxins in cashew by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Bi, Ruifeng; Fan, Zhixian; Fu, Meng

    2011-12-01

    A method for the determination of four aflatoxins in cashew using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed. The sample was extracted with methanol-water (8: 2, v/v) solution, followed by a cleanup procedure with Florisil column. The target compounds were eluted using 5 mL acetone-water-formic acid (96: 3.5:0.5, v/v/v) solution. The eluate was dried under N2, then dissolved in 1 mL methanol. Four aflatoxins were separated in MG C18 column (100 mm x 3.0 mm, 3 microm) adopting a gradient program within 15 min. A triple quadrupole mass spectrometry equipped with an electrospray ionization source operated in the positive ion mode was used to detect the aflatoxins. The good correlation coefficients (r2 > 0.997) of the four aflatoxins were obtained within their respective linear ranges. The limits of detection (S/N = 3) were between 0.009 microg/kg and 0.04 microg/kg, and the limits of quantification (S/N = 10) were between 0.03 microg/kg and 0.12 microg/kg. The recoveries were in a range of 63.0% -78.5% with the relative standard deviations (RSDs) varied from 2.8% to 9.1%. The validation results meet the requirements of trace assay. Matrix effects were estimated and the signal suppression/enhancement ranged from 88.8% to 99.4%. The results indicate that the developed method is simple, fast, accurate, and can be applied for the determination of fours aflatoxins in cashew.

  7. [Determination of aflatoxins in cereals and oils by liquid chromatography-triple quadrupole tandem mass spectrometry].

    Science.gov (United States)

    Wang, Xiupin; Li, Peiwu; Yang, Yang; Zhang, Wen; Zhang, Qi; Fan, Sufang; Yu, Li; Wang, Lin; Chen, Xiaomei; Li, Ying; Jiang, Jun

    2011-06-01

    The high performance liquid chromatography (HPLC)-triple quadrupole tandem mass spectrometry was applied for the determination of the aflatoxins: B1 (AFB1), B2 (AFB2), G1 (AFG1) and G2 (AFG2), in cereals and oils. The samples were first extracted by ultrasonic method. The optimized conditions of ultrasonic extraction were as follows: temperature of 50 degrees C, extraction time of 3 min, methanol-water (containing 40 g/L NaCl) (80: 20, v/v) solution as the medium and a ratio of sample to solvent of 1 : 3 (g: mL). The extracts were then purified using an immunoaffinity column. The separation was performed on a C18 column with mobile phases of 10 mmol/L ammonium acetate and methanol in gradient elution. The sensitive detection of the four AFT compounds by electrospray ionization mass spectrometry (ESI-MS) was carried out in selected reaction monitoring (SRM) mode with aflatoxin M1 (AFM1) as the internal standard. Under the optimized conditions, the limits of detection of AFB1, AFB2, AFG1 and AFG2 were 0.002, 0.004, 0.004 and 0.012 microg/kg, respectively. The recoveries of aflatoxins in different spiked cereals and oils were in the range from 87% to 111%. The intra-day and inter-day precisions were not more than 6.7% and 5.6%, respectively. In comparison with the external standard method, this method can effectively inhibit the matrix effects, and greatly improve the accuracy. PMID:22032163

  8. Determination of bedaquiline in human serum using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Alffenaar, Jan-Willem C; Bolhuis, Mathieu; van Hateren, Kai; Sturkenboom, Marieke; Akkerman, Onno; de Lange, Wiel; Greijdanus, Ben; van der Werf, Tjip; Touw, Daan

    2015-09-01

    Bedaquiline, a diarylquinoline for the treatment of multidrug-resistant tuberculosis (TB), relies on exposure-dependent killing. As data on drug exposure in specific populations are scarce, pharmacokinetic studies may be of interest. No simple and robust validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been reported to date. Therefore, a new method using a quadrupole mass spectrometer was developed for analysis of bedaquiline and N-monodesmethyl bedaquiline (M2) in human serum, using deuterated bedaquiline as the internal standard. The calibration curve was linear over a range of 0.05 (lower limit of quantification [LLOQ]) to 6.00 mg/liter for both bedaquiline and M2, with correlation coefficient values of 0.997 and 0.999, respectively. The calculated accuracy ranged from 1.9% to 13.6% for bedaquiline and 2.9% to 8.5% for M2. Within-run precision ranged from 3.0% to 7.2% for bedaquiline and 3.1% to 5.2% for M2, and between-run precision ranged from 0.0% to 4.3% for bedaquiline and 0.0% to 4.6% for M2. Evaluation of serum concentrations in a patient receiving bedaquiline showed high levels at the end of treatment, reflecting accumulation of the drug. More observational pharmacokinetic data are needed to relate altered drug concentrations to clinical outcome or adverse drug effects. A simple LC-MS/MS method to quantify bedaquiline and M2 levels in human serum using a deuterated internal standard has been validated. This method can be used in clinical studies and daily practice. PMID:26149993

  9. Direct tandem mass spectrometric analysis of amino acids in plasma using fluorous derivatization and monolithic solid-phase purification.

    Science.gov (United States)

    Tamashima, Erina; Hayama, Tadashi; Yoshida, Hideyuki; Imakyure, Osamu; Yamaguchi, Masatoshi; Nohta, Hitoshi

    2015-11-10

    In this study, we developed a novel direct tandem mass spectrometric method for rapid and accurate analysis of amino acids utilizing a fluorous derivatization and purification technique. Amino acids were perfluoroalkylated with 2H,2H,3H,3H-perfluoroundecan-1-al in the presence of 2-picoline borane via reductive amination. The derivatives were purified by perfluoroalkyl-modified silica-based monolithic solid-phase extraction (monolithic F-SPE), and directly analyzed by tandem mass spectrometry using electrospray ionization without liquid chromatographic separation. The perfluoroalkyl derivatives could be sufficiently distinguished from non-fluorous compounds, i.e. the biological matrix, due to their fluorous interaction. Thus, rapid and accurate determination of amino acids was accomplished. The method was validated with human plasma samples and applied to the analysis of amino acids in the plasma of mice with maple syrup urine disease or phenylketonuria.

  10. Automated processing of whole blood samples for the determination of immunosuppressants by liquid chromatography tandem-mass spectrometry

    OpenAIRE

    Vogeser, Michael; Spöhrer, Ute

    2006-01-01

    Background: Liquid chromatography tandem-mass spectrometry (LC-MS/MS) is an efficient technology for routine determination of immunosuppressants in whole blood; however, time-consuming manual sample preparation remains a significant limitation of this technique. Methods: Using a commercially available robotic pipetting system (Tecan Freedom EVO), we developed an automated sample-preparation protocol for quantification of tacrolimus in whole blood by LC-MS/MS. Barcode reading, sample resuspens...

  11. High performance liquid chromatography-tandem mass spectrometry of pharmaceuticals and personal care products in environmental and biological matrices

    OpenAIRE

    Purcell, Martha

    2009-01-01

    Pharmaceuticals and personal care products (PPCPs) have emerged in recent years as a new class of chemical and biological pollutants in our environment. In the search for suitably sensitive and specific techniques for detection of these compounds at very low concentrations, liquid chromatography-tandem mass spectrometry (LCMS/ MS) has emerged as the new technique of choice. This work describes methods for screening and quantification of various pharmaceutical and illicit drug residues i...

  12. A high-resolution tandem mass spectrometer for the collision-induced dissociation of large molecule ions

    International Nuclear Information System (INIS)

    Instrumental development in the field of tandem mass spectrometry is described in order to use the technique for the analysis of large organic molecules. Experiments are also described in which the process of collision-induced dissociation (CID) is investigated. The fragmentation pattern of CH4+ has been measured for three different target gases He, Ar and Xe. From these measurements fragmentation cross sections are calculated. 192 refs.; 47 figs.; 6 tabs

  13. Simultaneous determination of 14 β-lactam antibiotics in cosmetic products by liquid chromatography tandem mass spectrometry method

    Institute of Scientific and Technical Information of China (English)

    Cai Sheng Wu; Jin Lan Zhang; Yan Ling Qiao; Yi Lin Wang; Zhi Rong Chen

    2011-01-01

    In this study, a simple and rapid high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was established and validated to determine the 14 β-lactam antibiotics in cosmetic products, including 1 (ceftazidime), 2 (cefaclor), 3 (cefdinir), 4 (ampicillin), 5 (cefalexin), 6 (ceftezole), 7 (cefotaxim), 8 (cefradine), 9 (cefuroxime), 10 (cephazoline), 11 (cefathiamidine), 12 (cefoperazone), 13 (cafalotin), 14 (piperacillin).

  14. Analysis of Androgenic Steroids in Environmental Waters by Large-volume Injection Liquid Chromatography Tandem Mass Spectrometry

    OpenAIRE

    Backe, Will J.; Ort, Christoph; Brewer, Alex J.; Field, Jennifer A.

    2011-01-01

    A new method was developed for the analysis of natural and synthetic androgenic steroids and their selected metabolites in aquatic environmental matrices using direct large-volume injection (LVI) high performance liquid chromatography (HPLC) tandem mass spectrometry (MS/MS). Method accuracy ranged from 88 to 108% for analytes with well-matched internal standards. Precision, quantified by relative standard deviation (RSD), was less than 12%. Detection limits for the method ranged from 1.2 to 3...

  15. Paclobutrazol Residue Determination in Potato and Soil Using Low Temperature Partition Extraction and Ultrahigh Performance Liquid Chromatography Tandem Mass Spectrometry

    OpenAIRE

    Hongcheng Liu; Tao Lin; Jia Mao; Huan Lu; Dongshun Yang; Jiliang Wang; Qiwan Li

    2015-01-01

    A simple, accurate, and highly sensitive analytical method was developed for determining the paclobutrazol residue in potato and soil, the dynamics dissipation in soil. Extraction was carried out by low temperature partitioning and analyzed by ultrahigh performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). For a favor extraction yield, the parameters such as temperature and solvent were optimized. The result showed that sample would be easily frozen and separated using ace...

  16. MEASUREMENT OF PYRETHROID RESIDUES IN ENVIRONMENTAL AND FOOD SAMPLES BY ENHANCED SOLVENT EXTRACTION/SUPERCRITICAL FLUID EXTRACTION COUPLED WITH GAS CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY

    Science.gov (United States)

    The abstract summarizes pyrethorid methods development research. It provides a summary of sample preparation and analytical techniques such as supercritical fluid extraction, enhance solvent extraction, gas chromatography and tandem mass spectrometry.

  17. Optimization of a liquid chromatography-tandem mass spectrometry method for quantification of the plant lignans secoisolariciresinol, matairesinol, lariciresinol and pinoresinol in foods

    NARCIS (Netherlands)

    Milder, I.E.J.; Arts, I.C.W.; Venema, D.P.; Lasaroms, J.J.P.; Wähälä, K.; Hollman, P.C.H.

    2004-01-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the quantification of the four major enterolignan precursors [secoisolariciresinol, matairesinol, lariciresinol, and pinoresinol] in foods. The method consists of alkaline methanolic extraction, followed by enzymati

  18. Identification of glutamic acid 78 as the active site nucleophile in Bacillus subtilis xylanase using electrospray tandem mass spectrometry.

    Science.gov (United States)

    Miao, S; Ziser, L; Aebersold, R; Withers, S G

    1994-06-14

    A new mechanism-based inactivator of beta-1,4-xylanases, 2',4'-dinitrophenyl 2-deoxy-2-fluoro-beta-xylobioside, has been synthesized and used to trap the covalent intermediate formed during catalysis by Bacillus subtilis xylanase. Electrospray mass spectrometry confirmed the 1:1 stoichiometry of the incorporation of inactivator into the enzyme. Inactivation of xylanase followed the expected pseudo-first-order kinetic behavior, and kinetic parameters were determined. The intermediate trapped was relatively stable toward hydrolytic turnover (t1/2 = 350 min). However, turnover could be facilitated by transglycosylation following the addition of the acceptor benzyl thio-beta-xylobioside, thus demonstrating the catalytic competence of the trapped intermediate. Reactivation kinetic parameters for this process of kre = 0.03 min-1 and Kre = 46 mM were determined. The nucleophilic amino acid was identified as Glu78 by a tandem mass spectrometric technique which does not require the use of radiolabels. The peptic digest of the labeled enzyme was separated by high-performance liquid chromatography and the eluent fed into a tandem mass spectrometer via an electrospray ionization device. The labeled peptide was identified as one of m/z = 826 (doubly charged) which fragmented in the collision chamber between the mass analyzers with loss of the mass of a 2-fluoroxylobiosyl unit. Confirmation of the peptide identity was obtained both by tandem mass spectrometric sequencing and by Edman degradation of the purified peptide. Glu78 is completely conserved in all members of this xylanase family and indeed is shown to be located in the active site in the recently determined X-ray crystal structure.

  19. Determination of tetracycline residues in soil by pressurized liquid extraction and liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Andreu, Vicente; Vazquez-Roig, Pablo; Blasco, Cristina; Picó, Yolanda

    2009-07-01

    An optimized extraction and cleanup method for the analysis of chlortetracycline (CTC), doxycycline (DC), oxytetracycline (OTC) and tetracycline (TC) in soil is presented. Soil extraction in a pressurized liquid extraction system, followed by extract clean up using solid-phase extraction (SPE) and tetracycline determination by liquid chromatography tandem mass spectrometry (LC-MS/MS) provided appropriate efficiency and reproducibility. Different dispersing agents and solvents for soil extraction and several SPE cartridges for cleanup were compared. The best extraction results were obtained using ethylenediamine tetraacetic acid-treated sand as dispersing agent, and water at 70 degrees C. The most effective cleanup was obtained using Strata-X sorbent in combination with a strong anion exchange cartridge. Recoveries ranged from 71% to 96% and precision, as indicated by the relative standard deviations, was within the range of 8-15%. The limits of quantification (LOQs) by using LC-MS/MS, based on signal-to-noise ratio (S/N) of 10, ranged from 1 microg kg(-1) for TC to 5 microg kg(-1) for CTC. These results pointed out that this technique is appropriate to determine tetracyclines in soils. Analysis of 100 samples taken in the Valencian Community revealed that, in soil, up to 5 microg kg(-1) CTC, 15 microg kg(-1) OTC, 18 microg kg(-1) TC, and 12 microg kg(-1) DC could be detected. Detection of the analytes in several samples, which typify great part of the Spanish agricultural soils, should be outlined as most important result of this study. PMID:19205670

  20. Determination of pharmaceuticals in biosolids using accelerated solvent extraction and liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Ding, Yunjie; Zhang, Weihao; Gu, Cheng; Xagoraraki, Irene; Li, Hui

    2011-01-01

    An analytical method was developed to quantitatively determine pharmaceuticals in biosolid (treated sewage sludge) from wastewater treatment plants (WWTPs). The collected biosolid samples were initially freeze dried, and grounded to obtain relatively homogenized powders. Pharmaceuticals were extracted using accelerated solvent extraction (ASE) under the optimized conditions. The optimal operation parameters, including extraction solvent, temperature, pressure, extraction time and cycles, were identified to be acetonitrile/water mixture (v/v 7:3) as extraction solvent with 3 extraction cycles (15 min for each cycle) at 100 °C and 100 bars. The extracts were cleaned up using solid-phase extraction followed by determination by liquid chromatography coupled with tandem mass spectrometry. For the 15 target pharmaceuticals commonly found in the environment, the overall method recoveries ranged from 49% to 68% for tetracyclines, 64% to 95% for sulfonamides, and 77% to 88% for other pharmaceuticals (i.e. acetaminophen, caffeine, carbamazepine, erythromycin, lincomycin and tylosin). The developed method was successfully validated and applied to the biosolid samples collected from WWTPs located in six cities in Michigan. Among the 15 target pharmaceuticals, 14 pharmaceuticals were detected in the collected biosolid samples. The average concentrations ranged from 2.6 μg/kg for lincomycin to 743.6 μg/kg for oxytetracycline. These results indicated that pharmaceuticals could survive wastewater treatment processes, and accumulate in sewage sludge and biosolids. Subsequent land application of the contaminated biosolids could lead to the dissemination of pharmaceuticals in soil and water environment, which poses potential threats to at-risk populations in the receiving ecosystems. PMID:21112593

  1. On-line high speed lipid extraction for nanoflow liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lee, Ju Yong; Yang, Joon Seon; Park, Se Mi; Byeon, Seul Kee; Moon, Myeong Hee

    2016-09-16

    An on-line lipid extraction method is introduced by utilizing a short capillary extraction column using HILIC and C4 particles prior to nanoflow liquid chromatography-tandem mass spectrometry (nLC-MS/MS). The on-line extraction using a urine sample spiked with PL standards showed similar or slightly higher recovery values (86%-96%) of phospholipids (PLs) compared to those obtained by the conventional off-line extraction based on the Folch method with or without using the air-exposed drying process. In this study, we demonstrated that PL oxidation can occur during the air-exposed drying process of lipid extracts in standard liquid-liquid extraction procedures, which was confirmed by the oxidized PL (OxPL) molecules that were generated from an off-line extraction using a few PL standards. Quantitative comparison of these OxPL species between on- and off-line extraction followed by nLC-MS/MS with multiple reaction monitoring (MRM) analysis showed a significant decrease (2-10 fold) in unwanted OxPL species when on-line extraction was employed. While the number of identified PLs from a urine sample was somewhat lower than those by off-line extraction, the number of OxPLs was significantly reduced (from 70 to 22) with on-line extraction. The new method offers high speed (∼5min) automated extraction of PLs with nLC-MS/MS analysis and presents the possibility of handling a biological sample with a very limited amount of lipids. PMID:27530420

  2. Detection of 36 antibiotics in coastal waters using high performance liquid chromatography-tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    NA Guangshui; GU Jia; GE Linke; ZHANG Peng; WANG Zhen; LIU Chunyang; ZHANG Lin

    2011-01-01

    Among pharmaceuticals and personal care products released into the aquatic environment,antibiotics are of particular concern,because of their ubiquity and health effects.Although scientists have recently paid more attention to the threat of antibiotics to coastal ecosystems,researchers have often focused on relatively few antibiotics,because of the absence of suitable analytical methods.We have therefore developed a method for the rapid detection of 36 antibiotic residues in coastal waters,including tetracyclines (TCs),sulfanilamides (SAs),and quinolones (QLs).The method consists of solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis,using electrospray ionization (ESI) in positive mode.The SPE was performed with Oasis HLB and Oasis MCX cartridges.Chromatographic separation on a C18 column was achieved using a binary eluent containing methanol and water with 0.1% formic acid.Typical recoveries of the analytes ranged from 67.4% to 109.3% at a fortification level of 100 ng/L.The precision of the method,calculated as relative standard deviation (RSD),was below 14.6% for all the compounds.The limits of detection (LODs) varied from 0.45 pg to 7.97 pg.The method was applied to determine the target analytes in coastal waters of the Yellow Sea in Liaoning,China.Among the tested antibiotics,31 were found in coastal waters,with their concentrations between the LOD and 212.5 ng/L.These data indicate that this method is valid for analysis of antibiotics in coastal waters.The study first reports such a large number of antibiotics along the Yellow Sea coast of Liaoning,and should facilitate future comprehensive evaluation of antibiotics in coastal ecosystems.

  3. Anion exchange SPE and liquid chromatography-tandem mass spectrometry in GHB analysis.

    Science.gov (United States)

    Elian, Albert A; Hackett, Jeffery

    2011-12-01

    In this study, the extraction of γ-hydroxybutyrate (GHB) from urine using solid-phase extraction (SPE) is described. SPE was performed on anion exchange columns after samples of urine had been diluted with de-ionized water. After application of the diluted samples containing GHB-d(6) as an internal standard, the sorbent was washed with deionized water and methanol and dried. The GHB was eluted from the SPE column with a solvent consisting of methanol containing 6% glacial acetic acid. The eluent was collected, evaporated to dryness, and dissolved in mobile phase (100 μL) for analysis by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in negative multiple reaction monitoring (MRM) mode. Liquid chromatography was performed in gradient mode employing a biphenyl column and a mobile phase consisting of acetontitrile (containing 0.1% formic acid) and 0.1% aqueous formic acid. The total run time for each analysis was less than 5 min. The limits of detection/quantification for this method were determined to be 50 and 100 ng/mL, respectively. The method was found to be linear from 500 ng/mL to 10,000 ng/mL (r(2)>0.995). The recovery of GHB was found to be greater than 75%. In this report, results of authentic urine samples analyzed for GHB by this method are presented. GHB concentrations in these samples were found to be range from less than 500 ng/mL to 5110 ng/mL.

  4. Detection of stanozolol in environmental waters using liquid chromatography tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Petroczi Andrea

    2011-10-01

    Full Text Available Abstract Background Owing to frequent administration of a wide range of pharmaceutical products, various environmental waters have been found to be contaminated with pharmacologically active substances. For example, stanozolol, a synthetic anabolic steroid, is frequently misused for performance enhancement as well as for illegal growth promoting purposes in veterinary practice. Previously we reported stanozolol in hair samples collected from subjects living in Budapest. For this reason we initiated this study to explore possible environmental sources of steroid contamination. The aim of this study was to develop a method to monitor stanozolol in aqueous matrices using liquid chromatography tandem mass spectrometry (LC-MS/MS. Results Liquid-liquid extraction using pentane was found to be an efficient method for the extraction of stanozolol from water samples. This was followed by direct detection using LC-MS/MS. The method was capable of detecting 0.25 pg/mL stanozolol when only 5 mL water was processed in the presence of stanozolol D3 as internal standard. Fifteen bottled waters analysed were found to be negative for stanozolol. However, three out of six samples from the Danube river, collected from December '09 to November '10, were found to contain stanozolol at concentrations up to 1.82 pg/mL. In contrast, only one sample (out of six of urban tap water from Budapest city was found to contain stanozolol, at a concentration of 1.19 pg/mL. Conclusion The method developed is efficient, rapid, reproducible, sensitive and robust for the detection of stanozolol in aqueous matrices.

  5. Nitroproteins in Human Astrocytomas Discovered by Gel Electrophoresis and Tandem Mass Spectrometry

    Science.gov (United States)

    Peng, Fang; Li, Jianglin; Guo, Tianyao; Yang, Haiyan; Li, Maoyu; Sang, Shushan; Li, Xuejun; Desiderio, Dominic M.; Zhan, Xianquan

    2015-12-01

    Protein tyrosine nitration is involved in the pathogenesis of highly fatal astrocytomas, a type of brain cancer. To understand the molecular mechanisms of astrocytomas and to discover new biomarkers/therapeutic targets, we sought to identify nitroproteins in human astrocytoma tissue. Anti-nitrotyrosine immunoreaction-positive proteins from a high-grade astrocytoma tissue were detected with two-dimensional gel electrophoresis (2DGE)-based nitrotyrosine immunoblots, and identified with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Fifty-seven nitrotyrosine immunopositive protein spots were detected. A total of 870 proteins (nitrated and non-nitrated) in nitrotyrosine-immunopositive 2D gel spots were identified, and 18 nitroproteins and their 20 nitrotyrosine sites were identified with MS/MS analysis. These nitroproteins participate in multiple processes, including drug-resistance, signal transduction, cytoskeleton, transcription and translation, cell proliferation and apoptosis, immune response, phenotypic dedifferentiation, cell migration, and metastasis. Among those nitroproteins that might play a role in astrocytomas was nitro-sorcin, which is involved in drug resistance and metastasis and might play a role in the spread and treatment of an astrocytoma. Semiquantitative immune-based measurements of different sorcin expressions were found among different grades of astrocytomas relative to controls, and a semiquantitative increased nitration level in high-grade astrocytoma relative to control. Nitro-β-tubulin functions in cytoskeleton and cell migration. Semiquantitative immunoreactivity of β-tubulin showed increased expression among different grades of astrocytomas relative to controls and semiquantitatively increased nitration level in high-grade astrocytoma relative to control. Each nitroprotein was rationalized and related to the corresponding functional system to provide new insights into tyrosine nitration and its potential role in the

  6. msmsEval: tandem mass spectral quality assignment for high-throughput proteomics

    Directory of Open Access Journals (Sweden)

    Cartwright Hugh M

    2007-02-01

    Full Text Available Abstract Background In proteomics experiments, database-search programs are the method of choice for protein identification from tandem mass spectra. As amino acid sequence databases grow however, computing resources required for these programs have become prohibitive, particularly in searches for modified proteins. Recently, methods to limit the number of spectra to be searched based on spectral quality have been proposed by different research groups, but rankings of spectral quality have thus far been based on arbitrary cut-off values. In this work, we develop a more readily interpretable spectral quality statistic by providing probability values for the likelihood that spectra will be identifiable. Results We describe an application, msmsEval, that builds on previous work by statistically modeling the spectral quality discriminant function using a Gaussian mixture model. This allows a researcher to filter spectra based on the probability that a spectrum will ultimately be identified by database searching. We show that spectra that are predicted by msmsEval to be of high quality, yet remain unidentified in standard database searches, are candidates for more intensive search strategies. Using a well studied public dataset we also show that a high proportion (83.9% of the spectra predicted by msmsEval to be of high quality but that elude standard search strategies, are in fact interpretable. Conclusion msmsEval will be useful for high-throughput proteomics projects and is freely available for download from http://proteomics.ucd.ie/msmseval. Supports Windows, Mac OS X and Linux/Unix operating systems.

  7. Quantitation of Cotinine in Nonsmoker Saliva Using Chip Based Nanoelectrospray Tandem Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tomkins, Bruce A [ORNL; Van Berkel, Gary J [ORNL; Jenkins, Roger A [ORNL; Counts, Richard Wayne [ORNL

    2006-01-01

    A new analytical procedure was developed for the quantitation of nonsmoker salivary cotinine. Small volumes of saliva were diluted with water, fortified with cotinine-d{sub 3} (internal standard), then passed through small extraction columns. The analyte and internal standard were eluted with 0.1% (v/v) acetic acid/acetonitrile. Aliquots of each extract were analyzed directly, without chromatographic separation, using chip-based (NanoMate{sup TM}) nanospray tandem mass spectrometry. The calculated detection limit was 0.49 ng cotinine/mL saliva. This method was used to quantify salivary cotinine collected from nonsmoking human subjects living in one of three environmental tobacco smoke (ETS) exposure categories or 'cells': 1. smoking home/smoking workplace; 2. smoking home/nonsmoking workplace; and 3. nonsmoking home/smoking workplace. Samples were collected during five sequential days, including Saturday, as part of a larger study to evaluate potential variability in exposure to ETS. Salivary cotinine measurements were made for the purpose of excluding misclassified smokers and for comparison with known levels of exposure to airborne nicotine in each exposure category. The concentrations observed were consistent with those reported from other large studies reported elsewhere. A non-parametric statistical test was applied to the data within each cell. No statistically significant differences were found between the mean cotinine concentrations collected on a weekday as compared to those collected on a weekend day. When the non-parametric test was applied to the three cells, a statistically significant difference was observed between cell 1 compared to cells 2 and 3. The salivary cotinine concentrations were thus statistically invariant over a five-day exposure period, and they were greatest under the conditions of smoking home and smoking workplace.

  8. Validation of keratan sulfate level in mucopolysaccharidosis type IVA by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tomatsu, Shunji; Montaño, Adriana M; Oguma, Toshihiro; Dung, Vu Chi; Oikawa, Hirotaka; de Carvalho, Talita Giacomet; Gutiérrez, María L; Yamaguchi, Seiji; Suzuki, Yasuyuki; Fukushi, Masaru; Kida, Kazuhiro; Kubota, Mitsuru; Barrera, Luis; Orii, Tadao

    2010-12-01

    Mucopolysaccharidosis type IVA (MPS IVA, Morquio A disease), a progressive lysosomal storage disease, causes skeletal chondrodysplasia through excessive storage of keratan sulfate (KS). KS is synthesized mainly in cartilage and released to the circulation. The excess storage of KS disrupts cartilage, consequently releasing more KS into circulation, which is a critical biomarker for MPS IVA. Thus, assessment of KS level provides a potential screening strategy and determines clinical course and efficacy of therapies. We have recently developed a tandem mass spectrometry liquid chromatography [LC/MS/MS] method to assay KS levels in blood. Forty-nine blood specimens from patients with MPS IVA [severe (n = 33), attenuated (n = 11) and undefined (n = 5)] were analyzed for comparison of blood KS concentration with that of healthy subjects and for correlation with clinical severity. Plasma samples were digested by keratanase II to obtain disaccharides of KS. Digested samples were assayed by LC/MS/MS. We found that blood KS levels (0.4-26 µg/ml) in MPS IVA patients were significantly higher than those in age-matched controls (0.67-4.6 µg/ml; P IVA peaked between 2 years and 5 years of age (mean 11.4 µg/ml). Blood KS levels in severe MPS IVA (mean 7.3 µg/ml) were higher than in the attenuated form (mean 2.1 µg/ml) (P = 0.012). We also found elevated blood KS levels in other types of MPS. These findings indicate that the new KS assay for blood is suitable for early diagnosis and longitudinal assessment of disease severity in MPS IVA.

  9. Determination of loperamide in human plasma and saliva by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Arafat, Tawfiq; Arafat, Basil; awad, Riad; awwad, Ahmad Abu

    2014-12-01

    A simple and sensitive liquid chromatography-tandem mass spectrometric method for quantification of loperamide in human plasma and saliva was developed and validated, and then successfully applied in pharmacokinetic clinical study to investigate and correlate bioavailability of Imodium(®) 2mg quartet tablet dose in both human plasma and saliva. Loperamide with labeled internal standard was extracted from its biological matrix by methanol as protein direct precipitant in single extraction step. Adequate chromatographic separation for analytes from plasma and saliva matrices was achieved using ACE C18 (50mm×2.1mm, 5μm) column, eluted by water/methanol/formic acid (30:70:0.1%, v/v), delivered isocratically at constant flow rate of 0.75ml/min. The method validation intends to investigate specificity, sensitivity, linearity, precision, accuracy, recovery, matrix effect and stability according to European guideline, and partial validation was applied on saliva, specificity, matrix effect, recovery, sensitivity, within and between day precision and accuracy. The calibration curve was linear through the range of 20-3000pg/ml in both plasma and saliva using a 50μl sample volume. The partial validation sections outcome in saliva was so close to those in plasma. The within- and between-day precisions were all below 8.7% for plasma and below 11.4% for saliva. Accuracies ranged from 94 to 105% for both matrices. In this study, 26 healthy volunteers participated in the clinical study, and 6 of gave their saliva samples in addition to plasma at the same time schedule. The pharmacokinetic parameters of Cmax, AUC0-t and AUC0-∞, Tmax and T1/2 in both plasma and saliva were calculated and correlated.

  10. Simultaneous quantification of multiple urinary naphthalene metabolites by liquid chromatography tandem mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Daniel C Ayala

    Full Text Available Naphthalene is an environmental toxicant to which humans are exposed. Naphthalene causes dose-dependent cytotoxicity to murine airway epithelial cells but a link between exposure and human pulmonary disease has not been established. Naphthalene toxicity in rodents depends on P450 metabolism. Subsequent biotransformation results in urinary elimination of several conjugated metabolites. Glucuronide and sulfate conjugates of naphthols have been used as markers of naphthalene exposure but, as the current studies demonstrate, these assays provide a limited view of the range of metabolites generated from the parent hydrocarbon. Here, we present a liquid chromatography tandem mass spectrometry method for measurement of the glucuronide and sulfate conjugates of 1-naphthol as well as the mercapturic acids and N-acetyl glutathione conjugates from naphthalene epoxide. Standard curves were linear over 2 log orders. On column detection limits varied from 0.91 to 3.4 ng; limits of quantitation from 1.8 to 6.4 ng. The accuracy of measurement of spiked urine standards was -13.1 to + 5.2% of target and intra-day and inter-day variability averaged 7.2 (± 4.5 and 6.8 (± 5.0 %, respectively. Application of the method to urine collected from mice exposed to naphthalene at 15 ppm (4 hrs showed that glutathione-derived metabolites accounted for 60-70% of the total measured metabolites and sulfate and glucuronide conjugates were eliminated in equal amounts. The method is robust and directly measures several major naphthalene metabolites including those derived from glutathione conjugation of naphthalene epoxide. The assays do not require enzymatic deconjugation, extraction or derivatization thus simplifying sample work up.

  11. Quantitation of Insulin Analogues in Serum Using Immunoaffinity Extraction, Liquid Chromatography, and Tandem Mass Spectrometry.

    Science.gov (United States)

    Van Der Gugten, J Grace; Wong, Sophia; Holmes, Daniel T

    2016-01-01

    Insulin analysis is used in combination with glucose, C-peptide, beta-hydroxybutyrate, and proinsulin determination for the investigation of adult hypoglycemia. The most common cause is the administration of too much insulin or insulin secretagogue to a diabetic patient or inadequate caloric intake after administration of either. Occasionally there is a question as to whether hypoglycemia has been caused by an exogenous insulin-whether by accident, intent, or even malicious intent. While traditionally this was confirmed by a low or undetectable C-peptide in a hypoglycemic specimen, this finding is not entirely specific and would also be expected in the context of impaired counter-regulatory response, fatty acid oxidation defects, and liver failure-though beta-hydroxybutyrate levels can lend diagnostic clarity. For this reason, insulin is often requested. However, popular automated chemiluminescent immunoassays for insulin have distinctly heterogeneous performance in detecting analogue synthetic insulins with cross-reactivities ranging from near 0 % to greater than 100 %. The ability to detect synthetic insulins is vendor-specific and varies between insulin products. Liquid Chromatography and Tandem Mass Spectrometry (LC-MS/MS) offers a means to circumvent these analytical issues and both quantify synthetic insulins and identify the specific type. We present an immunoaffinity extraction and LC-MS/MS method capable of independent identification and quantitation of native sequence insulins (endogenous, Insulin Regular, Insulin NPH), and analogues Glargine, Lispro, Detemir, and Aspart with an analytical sensitivity for endogenous insulin of between 1 and 2 μU/mL in patient serum samples.

  12. Pharmacokinetic study of nobiletin and tangeretin in rat serum by high-performance liquid chromatography-electrospray ionization-mass spectrometry

    Science.gov (United States)

    Nobiletin (NOB) and tangeretin (TAN), two of the main polymethoxylated flavones in citrus, influence a number of key biological pathways in mammalian cells. While the impacts of NOB and TAN on glucose homeostasis and cholesterol regulation have been investigated in human clinical trials, much inform...

  13. Metabolomics Analysis of Health Functions of Physalis Pubescens L. using by Ultra-performance Liquid Chromatography/Electrospray Ionization Quadruple Time-of-Flight Mass Spectrometry

    OpenAIRE

    Hang Chu; Hui Sun; Guang-Li Yan; Ai-Hua Zhang; Chang Liu; Hui Dong; Xiang-Cai Meng; Xi-Jun Wang

    2015-01-01

    Herbal medicines may benefit from metabolomics studies, and applying metabolomics may provide answers about which herbal interventions may be effective for individuals, which metabolic processes are triggered, and the subsequent chemical pathways of activity. Physalis pubescens L (PPL) is an herbal fruit for one year living plant and has been developed into healthy function's food. However, the mechanisms of health functions are still unclear. To comprehensively and holistically assess its an...

  14. Dual biosensor immunoassay-directed identification of fluoroquinolones in chicken muscle by liquid chromatography electrospray time-of-flight mass spectrometry

    NARCIS (Netherlands)

    Marchesini, G.R.; Haasnoot, W.; Delahaut, P.; Gercek, H.; Nielen, M.W.F.

    2007-01-01

    Fluoroquinolones (FQs) are synthetic antibiotics of broad-spectrum antibacterial activity widely used to treat infections in farmed fish, turkeys, pigs, calves and poultry. Monitoring these substances residues is therefore regulated by law. For the detection of FQs, we studied the feasibility of cou

  15. Characterization of steroidal saponins from Dioscorea villosa and D Cayennensis using ultrahigh performance liquid chromatography/electrospray ionization quadruple time-of-flight mass spectrometry

    Science.gov (United States)

    Steroidal saponins were reported to be the major physiologically active constituents in yams. The structural characteristics of steroidal saponins in methanolic extracts from dried rhizomes of two Dioscorea species (D. villosa L. and D. cayenensis Lam.) and dietary supplements have analyzed using U...

  16. Determination of olanzapine in whole blood using simple protein precipitation and liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Marie Katrine Klose; Johansen, Sys Stybe

    2009-01-01

    A simple, sensitive, and reproducible liquid chromatography-tandem mass spectrometry method has been developed and validated for the quantification of the antipsychotic drug olanzapine in whole blood using dibenzepine as internal standard (IS). After acidic methanol-induced protein precipitation...... of the whole blood samples, olanzapine and IS were chromatographed on a reversed-phase Zorbax Extend-C(18)-column at pH 9.0. Quantification was performed on a triple-quadrupole mass spectrometer employing electrospray ionization technique operating in multiple reaction monitoring and positive ion mode. Total...

  17. Application of liquid chromatography-tandem mass spectrometry in quantitative bioanalyses of organic molecules in aquatic environment and organisms.

    Science.gov (United States)

    Bussy, Ugo; Li, Ke; Li, Weiming

    2016-05-01

    Analytical methods using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of metabolites or contaminants (or both) in various tissues of aquatic organisms and in the aquatic environment have received increasing attention in the last few years. This review discusses the findings relevant to such procedures published between 2005 and 2015. The aim is to evaluate the advantages, restrictions, and performances of the procedures from sample preparation to mass spectrometry measurement. To support these discussions, a general knowledge on LC-MS/MS is also provided. PMID:26996906

  18. Analysis of a series of chlorogenic acid isomers using differential ion mobility and tandem mass spectrometry.

    Science.gov (United States)

    Willems, Jamie L; Khamis, Mona M; Mohammed Saeid, Waleed; Purves, Randy W; Katselis, George; Low, Nicholas H; El-Aneed, Anas

    2016-08-24

    Chlorogenic acids are among the most abundant phenolics found in the human diet. Of these, the mono-caffeoylquinic acids are the predominant phenolics found in fruits, such as apples and pears, and products derived from them. In this research, a comprehensive study of the electrospray ionization (ESI) tandem mass spectrometric (MS/MS) dissociation behavior of the three most common mono-caffeoylquinic acids, namely 5-O-caffeoylquinic acid (5-CQA), 3-O-caffeoylquinic acid (3-CQA) and 4-O-caffeoylquinic acid (4-CQA), were determined using both positive and negative ionization. All proposed structures of the observed product ions were confirmed with second-generation MS(3) experiments. Similarities and differences between the dissociation pathways in the positive and negative ion modes are discussed, confirming the proposed structures and the established MS/MS fingerprints. MS/MS dissociation was primarily driven via the cleavage of the ester bond linking the quinic acid moiety to the caffeic acid moiety within tested molecules. Despite being structural isomers with the same m/z values and dissociation behaviors, the MS/MS data in the negative ion mode was able to differentiate the three isomers based on ion intensity for the major product ions, observed at m/z 191, 179 and 173. This differentiation was consistent among various MS instruments. In addition, ESI coupled with high-field asymmetric waveform ion mobility spectrometry-mass spectrometry (ESI-FAIMS-MS) was employed for the separation of these compounds for the first time. By combining MS/MS data and differential ion mobility, a method for the separation and identification of mono-caffeoylquinic in apple/pear juice samples was developed with a run time of less than 1 min. It is envisaged that this methodology could be used to identify pure juices based on their chlorogenic acid profile (i.e., metabolomics), and could also be used to detect juice-to-juice adulteration (e.g., apple juice addition to pear juice

  19. Analysis of a series of chlorogenic acid isomers using differential ion mobility and tandem mass spectrometry.

    Science.gov (United States)

    Willems, Jamie L; Khamis, Mona M; Mohammed Saeid, Waleed; Purves, Randy W; Katselis, George; Low, Nicholas H; El-Aneed, Anas

    2016-08-24

    Chlorogenic acids are among the most abundant phenolics found in the human diet. Of these, the mono-caffeoylquinic acids are the predominant phenolics found in fruits, such as apples and pears, and products derived from them. In this research, a comprehensive study of the electrospray ionization (ESI) tandem mass spectrometric (MS/MS) dissociation behavior of the three most common mono-caffeoylquinic acids, namely 5-O-caffeoylquinic acid (5-CQA), 3-O-caffeoylquinic acid (3-CQA) and 4-O-caffeoylquinic acid (4-CQA), were determined using both positive and negative ionization. All proposed structures of the observed product ions were confirmed with second-generation MS(3) experiments. Similarities and differences between the dissociation pathways in the positive and negative ion modes are discussed, confirming the proposed structures and the established MS/MS fingerprints. MS/MS dissociation was primarily driven via the cleavage of the ester bond linking the quinic acid moiety to the caffeic acid moiety within tested molecules. Despite being structural isomers with the same m/z values and dissociation behaviors, the MS/MS data in the negative ion mode was able to differentiate the three isomers based on ion intensity for the major product ions, observed at m/z 191, 179 and 173. This differentiation was consistent among various MS instruments. In addition, ESI coupled with high-field asymmetric waveform ion mobility spectrometry-mass spectrometry (ESI-FAIMS-MS) was employed for the separation of these compounds for the first time. By combining MS/MS data and differential ion mobility, a method for the separation and identification of mono-caffeoylquinic in apple/pear juice samples was developed with a run time of less than 1 min. It is envisaged that this methodology could be used to identify pure juices based on their chlorogenic acid profile (i.e., metabolomics), and could also be used to detect juice-to-juice adulteration (e.g., apple juice addition to pear juice).

  20. Simultaneous Determination of 25 Common Pharmaceuticals in Whole Blood Using Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Marie Katrine Klose; Johansen, Sys Stybe

    2012-01-01

    An ultra-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of 25 common pharmaceuticals in whole blood. The selected pharmaceuticals represent the most frequently detected drugs in our forensic laboratory with basic properties...... such as analgesics, antidepressants, antihistamines, antihypertensives, antipsychotics and ß-blockers. Whole blood samples were extracted with butyl acetate after adjusting pH with 2M NaOH. The target analytes were separated on a 100 × 2.1 mm ACQUITY BEH 1.7 µm C18 column by a formic acid/acetonitrile gradient...... elution using a Waters ACQUITY Ultra-Performance Liquid Chromatography system. Quantification was performed on a Waters tandem quadrupole ACQUITY TQD using multiple reaction monitoring in positive mode. The analytes were eluted within 11 min. The limit of quantification (LOQ) ranged from 0.002 to 0.01 mg...

  1. [Determination of congo red in beef by high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry].

    Science.gov (United States)

    Lin, Hui; Xu, Chunxiang; Yan, Chunrong; Zhang, Zheng; Wang, Suilou

    2013-09-01

    A method was developed for the determination of congo red in beef. The analyte was identified by high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry (LC-QTOF MS) and quantitatively determined by ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry. After purified by liquid-liquid extraction, the congo red in the beef sample was separated on an Agilent ZORBAX Eclipse Plus C18 Rapid Resolution HD UPLC column (50 mm x 2.1 mm, 1.8 microm) HPLC , using 95% (volume percentage) methanol as the mobile phase at 0.2 mL/min. The detection was performed on an AB 4000 + triple quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operated in negative ion mode and multiple-reaction monitoring (MRM) mode. The results showed that the linear range of congo red mass concentration was 0.03 - 1 mg/L with the correlation coefficient of 0.999 8. The method had a good precision with the RSDs lower than 5% and the recoveries ranging from 88% to 91%. The limit of detection (LOD) of congo red was 0.01 mg/L. With good reproducibility, the method is simple, fast and effective for the determination of the illegally added congo red in beef and other meat products.

  2. Natural products in Glycyrrhiza glabra (licorice) rhizome imaged at the cellular level by atmospheric pressure matrix-assisted laser desorption/ionization tandem mass spectrometry imaging

    DEFF Research Database (Denmark)

    Li, Bin; Bhandari, Dhaka Ram; Janfelt, Christian;

    2014-01-01

    The rhizome of Glycyrrhiza glabra (licorice) was analyzed by high-resolution mass spectrometry imaging and tandem mass spectrometry imaging. An atmospheric pressure matrix-assisted laser desorption/ionization imaging ion source was combined with an orbital trapping mass spectrometer in order...

  3. Characterization of Wax Esters by Electrospray Ionization Tandem Mass Spectrometry: Double Bond Effect and Unusual Product Ions.

    Science.gov (United States)

    Chen, Jianzhong; Green, Kari B; Nichols, Kelly K

    2015-08-01

    A series of different types of wax esters (represented by RCOOR') were systematically studied by using electrospray ionization (ESI) collision-induced dissociation tandem mass spectrometry (MS/MS) along with pseudo MS(3) (in-source dissociation combined with MS/MS) on a quadrupole time-of-flight (Q-TOF) mass spectrometer. The tandem mass spectra patterns resulting from dissociation of ammonium/proton adducts of these wax esters were influenced by the wax ester type and the collision energy applied. The product ions [RCOOH2](+), [RCO](+) and [RCO-H2O](+) that have been reported previously were detected; however, different primary product ions were demonstrated for the three wax ester types including: (1) [RCOOH2](+) for saturated wax esters, (2) [RCOOH2](+), [RCO](+) and [RCO-H2O](+) for unsaturated wax esters containing only one double bond in the fatty acid moiety or with one additional double bond in the fatty alcohol moiety, and (3) [RCOOH2](+) and [RCO](+) for unsaturated wax esters containing a double bond in the fatty alcohol moiety alone. Other fragments included [R'](+) and several series of product ions for all types of wax esters. Interestingly, unusual product ions were detected, such as neutral molecule (including water, methanol and ammonia) adducts of [RCOOH2](+) ions for all types of wax esters and [R'-2H](+) ions for unsaturated fatty acyl-containing wax esters. The patterns of tandem mass spectra for different types of wax esters will inform future identification and quantification approaches of wax esters in biological samples as supported by a preliminary study of quantification of isomeric wax esters in human meibomian gland secretions.

  4. A generic method to identify plant viruses by high-resolution tandem mass spectrometry of their coat proteins.

    Science.gov (United States)

    Blouin, Arnaud G; Greenwood, David R; Chavan, Ramesh R; Pearson, Michael N; Clover, Gerard R G; MacDiarmid, Robin M; Cohen, Daniel

    2010-01-01

    Although a number of protocols have been developed for detection of viruses at the genus or family level, universal approaches to detect and identify unknown viruses are still required. High-resolution tandem mass spectrometry was used to identify accurately peptide masses and their constituent sequences from partially purified plant virus preparations. Analysis of the peptide fragment masses against a virus database using pattern-matching algorithms identified sequences with homology to known virus peptides and also predicted peptides using de novo sequence analysis. This method provided sufficient information to confirm the identity of two known viruses that were included as controls (Cucumber mosaic virus and Tomato spotted wilt virus) and to identify unknown viruses in six viral isolates. The unknown viruses have been identified as four common viruses (Alfalfa mosaic virus, Tobacco streak virus, Citrus leaf blotch virus and Ribgrass mosaic virus), and two novel viruses (a potexvirus and a vitivirus). The identification of viruses from five distinct families by the tandem mass spectrometric determination of their coat protein demonstrates that this is a useful method for initial virus identification. This method, complemented with molecular or immunological procedures, provides a rapid and convenient way to identify both known and novel plant viruses. PMID:19712699

  5. Detection of 10 sweeteners in various foods by liquid chromatography/tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Chui-Shiang Chang

    2014-09-01

    Full Text Available The analytical method for sweeteners in various food matrixes is very important for food quality control and regulation enforcement. A simple and rapid method for the simultaneous determination of 10 sweeteners [acesulfame potassium (ACS-K, aspartame (ASP, cyclamate (CYC, dulcin (DUL, glycyrrhizic acid (GA, neotame (NEO, neohesperidin dihydrochalcone (NHDC, saccharin (SAC, sucralose (SCL, and stevioside (STV] in various foods by liquid chromatography/tandem mass chromatography (LC–MS/MS was developed. The chromatographic separation was performed on a Phenomenex Luna Phenyl-Hexyl (5 μm, 4.6 mm × 150 mm column with gradient elution of 10 mM ammonium acetate in water and 10 mM ammonium acetate in methanol. The recoveries of the 10 sweeteners were between 75% and 120%, and the coefficients of variation were less than 20%. The limits of quantification were 0.5 μg/kg for NHDC and SCL. For the other sweeteners, the limits of quantification were 0.1 μg/kg. Compared to the traditional high-performance liquid chromatography method, the LC–MS/MS method could provide better sensitivity, higher throughput, enhanced specificity, and more sweeteners analyzed in a single run. The samples included 27 beverages (16 alcoholic and 11 nonalcoholic beverages and 15 pickled foods (1 pickled pepper, 3 candies, and 11 candied fruits. Two remanufactured wines were found to contain 7.2, 8.5 μg/g SAC and 126.5, 123 μg/g CYC, respectively. ACS-K, ASP, SCL, and NEO were detected in five beverages and drinks. The pickled peppers and candied fruits were found to contain SAC, GA, CYC, ASP, STV, NEO, and ACS-K. The wine with sweeteners detected was remanufactured wine, not naturally fermented wine. Therefore, the ingredient label for the sweeteners of remanufactured wine should be regulated by the proper authority for inspection of sweeteners.

  6. Quantification of Neurotransmitters in Mouse Brain Tissue by Using Liquid Chromatography Coupled Electrospray Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Tae-Hyun Kim

    2014-01-01

    Full Text Available A simple and rapid liquid chromatography tandem mass spectrometry method has been developed for the determination of BH4, DA, 5-HT, NE, EP, Glu, and GABA in mouse brain using epsilon-acetamidocaproic acid and isotopically labeled neurotransmitters as internal standards. Proteins in the samples were precipitated by adding acetonitrile, and then the supernatants were separated by a Sepax Polar-Imidazole (2.1 mm × 100 mm, i.d., 3 μm column by adding a mixture of 10 mM ammonium formate in acetonitrile/water (75 : 25, v/v, 300 μl/min for BH4 and DA. To assay 5-HT, NE, EP, Glu, and GABA; a Luna 3 μ C18 (3.0 mm × 150 mm, i.d., 3 μm column was used by adding a mixture of 1% formic acid in acetonitrile/water (20 : 80, v/v, 350 μl/min. The total chromatographic run time was 5.5 min. The method was validated for the analysis of samples. The calibration curve was linear between 10 and 2000 ng/g for BH4 r2=0.995, 10 and 5000 ng/g for DA r2=0.997, 20 and 10000 ng/g for 5-HT r2=0.994, NE r2=0.993, and EP r2=0.993, and 0.2 and 200 μg/g for Glu r2=0.996 and GABA r2=0.999 in the mouse brain tissues. As stated above, LC-MS/MS results were obtained and established to be a useful tool for the quantitative analysis of BH4, DA, 5-HT, NE, EP, Glu, and GABA in the experimental rodent brain.

  7. Sensitive, Preclinical Detection of Prions in Brain by nanospray liquid chromatography/tandem mass spectrometry

    Science.gov (United States)

    More sensitive detection of prions in brain is important because it would allow early detection of disease in young animals and assure a safer food supply. We quantitated the amount of proteinase K-resistant prion protein (PrP 27-30) by use of nano-scale liquid chromatography coupled to a tandem ma...

  8. Liquid chromatography-mass spectrometric and liquid chromatography-tandem mass spectrometric determination of hallucinogenic indoles psilocin and psilocybin in "magic mushroom" samples.

    Science.gov (United States)

    Kamata, Tooru; Nishikawa, Mayumi; Katagi, Munehiro; Tsuchihashi, Hitoshi

    2005-03-01

    Accurate and sensitive analytical methods for psilocin (PC) and psilocybin (PB), tryptamine-type hallucinogens contained in "magic mushrooms," were investigated using liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS). The chromatographic separation on an ODS column and mass spectral information gave complete discrimination between PC and PB without derivatization. The mass spectrometric detection had a high sensitivity, and the tandem mass spectrometric detection provided more specificity and accuracy, as well as high sensitivity. The detection limits ranged from 1 to 25 pg by LC-MS in the selected ion monitoring mode, and the intra- and inter-day coefficients of variation were estimated to be 4.21-5.93% by LC-MS-MS in the selected reaction monitoring mode. By applying the present LC-MS-MS technique to four real samples, the contents of PC and PB were found to vary over a wide range (0.60-1.4 and 0.18-3.8 mg/g dry wt. for PC and PB, respectively) between samples.

  9. MALDI mass spectrometry imaging of N-glycans on tibial cartilage and subchondral bone proteins in knee osteoarthritis.

    Science.gov (United States)

    Briggs, Matthew T; Kuliwaba, Julia S; Muratovic, Dzenita; Everest-Dass, Arun V; Packer, Nicolle H; Findlay, David M; Hoffmann, Peter

    2016-06-01

    Magnetic resonance imaging (MRI) is a non-invasive technique routinely used to investigate pathological changes in knee osteoarthritis (OA) patients. MRI uniquely reveals zones of the most severe change in the subchondral bone (SCB) in OA, called bone marrow lesions (BMLs). BMLs have diagnostic and prognostic significance in OA, but MRI does not provide a molecular understanding of BMLs. Multiple N-glycan structures have been observed to play a pivotal role in the OA disease process. We applied matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) of N-glycans to formalin-fixed paraffin-embedded (FFPE) SCB tissue sections from patients with knee OA, and liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) was conducted on consecutive sections to structurally characterize and correlate with the N-glycans seen by MALDI-MSI. The application of this novel MALDI-MSI protocol has enabled the first steps to spatially investigate the N-glycome in the SCB of knee OA patients. PMID:26992165

  10. Quantification of Modified Tyrosines in Healthy and Diabetic Human Urine using Liquid Chromatography/Tandem Mass Spectrometry

    OpenAIRE

    Kato, Yoji; Dozaki, Natsuko; Nakamura, Toshiyuki; Kitamoto, Noritoshi; Yoshida, Akihiro; Naito, Michitaka; Kitamura, Masayasu; Osawa, Toshihiko

    2008-01-01

    The quantification of urinary oxidized tyrosines, dityrosine (DiY), nitrotyrosine (NY), bromotyrosine (BrY), and dibromotyrosine (DiBrY), was accomplished by quadruple liquid chromatography-tandem mass spectrometry (LC/MS/MS). The sample was partially purified by solid phase extraction, and was then applied to the LC/MS/MS using multiple-reaction monitoring (MRM) methods. The analysis for the DiY quantification was done first. The residual samples were further butylated with n-butanol/HCl, an...

  11. Characterizing some gossypol and gossypolone Schiff's bases by studying their fragmentation patterns with electrospray ionization tandem mass spectra

    Institute of Scientific and Technical Information of China (English)

    Long Zhang; Xing Xin Cao; Hai Xia Jiang; Biao Jiang; Yu Xin Cui

    2009-01-01

    To investigate the structural form of gossypol and gossypolone Schiff's bases, seven relevant Schiff's bases were synthesized and the eleetrospray ionization-tandem mass spectrometry (ESI-MS/MS) with low-energy collision-induced dissociation was used to analyze their fragmentations. A common fragmentation pathway with the loss of RNH2 from those schiff's bases quasi-molecular ions was observed and proposed on the basis of their MS/MS spectra data. This common pathway indicated that those Schiff's bases existed mainly as the enamine form not the imine form previously showed in most reports.

  12. High-Performance Liquid Chromatographic-Tandem Mass Spectrometric Determination of Itraconazole in Human Plasma for Bioavailability and Bioequivalence Studies

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Wook; Nam, Dae Young; Kang, Kyoung Hoon; Ha, Kyung Wook; Han, In Hee; Chang, Byung Kon; Yoon, Mi Kyeong; Lee, Jae Hwi [Chung-Ang University, Seoul (Korea, Republic of)

    2006-02-15

    A highly sensitive high-performance liquid chromatographic-tandem mass spectrometric method (HPLC-MSMS) has been developed to quantify itraconazole in human plasma for the purpose of pharmacokinetic studies. Sample preparation was carried out by liquid-liquid extraction using loratadine as an internal standard. Chromatographic separation used a YMC C{sub 18} column, giving an extremely fast total run time of 3 min. The method was validated and used for the bioequivalence study of itraconazole tablets in healthy male volunteers (n = 31). The lower limit of detection proved to be 0.2 ng /mL for itraconazole.

  13. Hydrogen atom scrambling in selectively labeled anionic peptides upon collisional activation by MALDI tandem time-of-flight mass spectrometry

    DEFF Research Database (Denmark)

    Bache, Nicolai; Rand, Kasper Dyrberg; Roepstorff, Peter;

    2008-01-01

    have now measured the level of hydrogen scrambling in a deprotonated, selectively labeled peptide using MALDI tandem time-of-flight mass spectrometry. Our results conclusively show that hydrogen scrambling is prevalent in the deprotonated peptide upon collisional activation. The amide hydrogens ((1)H......We have previously shown that peptide amide hydrogens undergo extensive intramolecular migration (i.e., complete hydrogen scrambling) upon collisional activation of protonated peptides (Jørgensen et al. J. Am. Chem. Soc. 2005, 127, 2785-2793). The occurrence of hydrogen scrambling enforces severe....../(2)H) have migrated extensively in the anionic peptide, thereby erasing the original regioselective deuteration pattern obtained in solution....

  14. Screening and determination of drugs in human saliva utilizing microextraction by packed sorbent and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Abdel-Rehim, Abbi; Abdel-Rehim, Mohamed

    2013-09-01

    This study presents a new method for collecting and handling saliva samples using an automated analytical microsyringe and microextraction by packed syringe (MEPS). The screening and determination of lidocaine in human saliva samples utilizing MEPS and liquid chromatography-tandem mass spectrometry (LC-MS/MS) were carried out. An exact volume of saliva could be collected. The MEPS C8 -cartridge could be used for 50 extractions before it was discarded. The extraction recovery was about 60%. The pharmacokinetic curve of lidocaine in saliva using MEPS-LC-MS/MS is reported.

  15. Rapid quantification of the metabolite of valacyclovir hydrochloride in human plasma by liquid chromatography-tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Objective To establish a rapid,sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of acyclovir (the metabolite of valacyclovir hydrochloride) in human plasma. Methods After addition of ganciclovir as internal standard (IS),plasma samples were prepared by one-step protein precipitation using acetonitrile as precipitant,followed by an isocratic elution with 0.1% formic acid solution-methanol (95∶5,v/v) on an Agilent ZORBAX SB-C18 (150mm×2.1mm i.d.,3....

  16. The application of Guided Ion Beam Tandem Mass Spectrometer; Bond dissociation energies of bare and ligated copper group cluster anions

    International Nuclear Information System (INIS)

    Threshold energies, fragmentation patterns, and integral cross sections for the reactions of collision induced dissociations of bare and ligated copper group cluster anions are determined using a Guided Ion Beam Tandem Mass Spectrometer (GIB-MS). The bond breaking patterns for the copper cluster anions show dramatic even/odd tendencies, e.g., all copper group anions generate as the predominant reaction product, Carbon monoxide is weakly bound to copper group cluster anions. Cohesive energies of the bare copper and silver cluster anions are determined and exhibit a good correspondence with estimate cohesive energies by the model of Miedema.

  17. Transmission Mode Ion/Ion Reactions in the RF-only Ion Guide of Hybrid Tandem Mass Spectrometers

    OpenAIRE

    Emory, Joshua F; Hassell, Kerry H.; Londry, Frank A.; McLuckey, Scott A.

    2009-01-01

    Transmission mode ion/ion reactions have been performed within the first quadrupole, the Q0 RF-only quadrupole, of two types of hybrid tandem mass spectrometers (viz., triple quadrupole/linear ion trap and QqTOF instruments). These transmission mode reactions involved the storage of either the reagent species and the transmission of the analyte species through the Q0 quadrupole for charge inversion reactions or the storage of the analyte ions and transmission of the reagent ions as in charge ...

  18. [Simultaneous determination of 16 flavonoids in the ginkgo dietary supplement tea by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Jiang, Yalan; Huang, Fang; Wu, Fuhai; Wu, Huiqin; Huang, Xiaolan; Deng, Xin

    2015-10-01

    A method for the determination of 16 functional components of ginkgo dietary supplement tea such as catechin, vitexin, puerarin, isoflavoues aglycone, silymarin, quercetin, luteolin, apigenin, naringenin, hesperitin dihydrochalcone, kaempferol, hesperitin, isorhamnetin, baicalein, nobiletin and tangeretin by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was proposed. The conditions of chromatography and mass spectrometry were optimized. The 16 flavonoids were separated on a C18 chromatographic column with acetonitrile and water (additional 0.1% formic acid) as mobile phases under gradient elution at a flow rate of 0.25 mL/min. The determination was conducted by tandem mass spectrometry in positive ESI mode under multiple reaction monitoring (MRM) mode. Good linearities for all the compounds, with correlation coefficients over 0.996, were acquired. The recoveries were in the range of 70.9% to 100.0% (n = 6), while the relative standard deviations (RSDs) were less than 10%. The results showed that the nine flavonoids, which were kaempferol, quercetin, hesperitin, vitexin, luteolin, catechin, apigenin, naringenin and isorhamnetin, were higher in contents among the 16 flavonoids in real samples, and they constituted up to 99.6% of the total flavonoids. The contents of these nine flavonoids can be considered as the quality control index of the ginkgo dietary supplement tea. The method proved to be rapid, selective, sensitive and stable, and it can be applied to control the quality of the ginkgo dietary supplement tea. PMID:26930959

  19. Pivotal Role of Computers and Software in Mass Spectrometry - SEQUEST and 20 Years of Tandem MS Database Searching

    Science.gov (United States)

    Yates, John R.

    2015-11-01

    Advances in computer technology and software have driven developments in mass spectrometry over the last 50 years. Computers and software have been impactful in three areas: the automation of difficult calculations to aid interpretation, the collection of data and control of instruments, and data interpretation. As the power of computers has grown, so too has the utility and impact on mass spectrometers and their capabilities. This has been particularly evident in the use of tandem mass spectrometry data to search protein and nucleotide sequence databases to identify peptide and protein sequences. This capability has driven the development of many new approaches to study biological systems, including the use of "bottom-up shotgun proteomics" to directly analyze protein mixtures.

  20. Evaluation of relative isotopic abundance measurements in a quadrupole time-of-flight mass spectrometer for elemental composition determination of natural products in traditional Chinese medicine.

    Science.gov (United States)

    Wu, Zhi-Jun; Huo, Jia-Li; Chen, Jian-Zhong; Li, Na; Fang, Dong-Mei; Chen, Xiao-Zhen; Zhang, Guo-Lin; Wang, Jian-Hua; Xu, Xiao-Ying

    2013-01-01

    The relative isotopic abundance (RIA) measurement errors of a quadrupole time-of-flight (Q-ToF) instrument incorporating analog-to-digital converter detectors were systemically evaluated by stochastically collecting about 200 data in positive ion mass spectrometry (MS) mode. Errors varied with peak intensities at definite spectral acquisition rates but were very close, even if peak intensities changed sharply at different spectral acquisition rates with the same concentration. Intensity thresholds were systematically defined at 1 Hz of spectral acquisition rates. RIA measurement errors were also evaluated using peak area. It seemed that peak area was better adapted for the high-intensity ions while peak intensity was suited for very low-intensity ions. Several known compounds were selected for RIA measurements for product ions in tandem mass spectropmetry (MS/MS) mode. An extract of a representative traditional Chinese medicinal, Paederia scandens was analyzed with high-performance liquid chromatography-electrospray ionization-QToF-MS/MS. The unique elemental compositions of some compounds could not be identified even with exact masses and MS/MS spectra of measured and reference compounds. RIA errors, especially of (M+2)M(-1), provided vital information for determining the elemental composition. PMID:24261081

  1. Determination of Phytochelatins in Rice by Stable Isotope Labeling Coupled with Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Liu, Ping; Cai, Wen-Jing; Yu, Lei; Yuan, Bi-Feng; Feng, Yu-Qi

    2015-07-01

    A highly sensitive method was developed for the detection of phytochelatins (PCs) in rice by stable isotope labeling coupled with liquid chromatography-electrospray ionization-tandem mass spectrometry (IL-LC-ESI-MS/MS) analysis. A pair of isotope-labeling reagents [ω-bromoacetonylquinolinium bromide (BQB) and BQB-d(7)] were used to label PCs in plant sample and standard PCs, respectively, and then combined prior to LC/MS analysis. The heavy labeled standards were used as the internal standards for quantitation to minimize the matrix and ion suppression effects in MS analysis. In addition, the ionization efficiency of PCs was greatly enhanced through the introduction of a permanent charged moiety of quaternary ammonium of BQB into PCs. The detection sensitivities of PCs upon BQB labeling improved by 14-750-fold, and therefore, PCs can be quantitated using only 5 mg of plant tissue. Furthermore, under cadmium (Cd) stress, we found that the contents of PCs in rice dramatically increased with the increased concentrations and treatment time of Cd. It was worth noting that PC5 was first identified and quantitated in rice tissues under Cd stress in the current study. Taken together, this IL-LC-ESI-MS/MS method demonstrated to be a promising strategy in detection of PCs in plants with high sensitivity and reliability.

  2. Analysis of small carbohydrates in several bioactive botanicals by gas chromatography with mass spectrometry and liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Moldoveanu, Serban; Scott, Wayne; Zhu, Jeff

    2015-11-01

    Bioactive botanicals contain natural compounds with specific biological activity, such as antibacterial, antioxidant, immune stimulating, and taste improving. A full characterization of the chemical composition of these botanicals is frequently necessary. A study of small carbohydrates from the plant materials of 18 bioactive botanicals is further described. The study presents the identification of the carbohydrate using a gas chromatographic-mass spectrometric analysis that allows detection of molecules as large as maltotetraose, after changing them into trimethylsilyl derivatives. A number of carbohydrates in the plant (fructose, glucose, mannose, sucrose, maltose, xylose, sorbitol, and myo-, chiro-, and scyllo-inositols) were quantitated using a novel liquid chromatography with tandem mass spectrometric technique. Both techniques involved new method developments. The gas chromatography with mass spectrometric analysis involved derivatization and separation on a Rxi(®)-5Sil MS column with H2 as a carrier gas. The liquid chromatographic separation was obtained using a hydrophilic interaction type column, YMC-PAC Polyamine II. The tandem mass spectrometer used an electrospray ionization source in multiple reaction monitoring positive ion mode with the detection of the adducts of the carbohydrates with Cs(+) ions. The validated quantitative procedure showed excellent precision and accuracy allowing the analysis in a wide range of concentrations of the analytes.

  3. Determination of polar pesticides in olive oil and olives by hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry and high resolution mass spectrometry.

    Science.gov (United States)

    Nortes-Méndez, Rocío; Robles-Molina, José; López-Blanco, Rafael; Vass, Andrea; Molina-Díaz, Antonio; Garcia-Reyes, Juan F

    2016-09-01

    This article reports the development of two HPLC-MS methods for the determination of polar pesticides in olive oil and olive samples by hydrophilic interaction liquid chromatography (HILIC) separation followed by mass spectrometry detection with tandem mass spectrometry using a triple quadrupole instrument operated in multiple reaction monitoring mode (HILIC-MS/MS) or electrospray time-of-flight mass spectrometry (HILIC-TOFMS). The selected polar pesticides included in the study were: amitrol, cyromazine, diquat, paraquat, mepiquat, trimethylsulfonium (trimesium, glyphosate counterion) and fosetyl aluminium. The simple sample treatment procedure was based on liquid partitioning with methanol. The performance of the sample extraction was evaluated in terms of recovery rates and matrix effects in both olive oil and olives matrices. The results obtained for olive oil were satisfactory while, due to the high complexity of olives, poor recovery rates were obtained for the extraction of diquat, paraquat and amitrol, although with a reasonable precision enabling its use in routine analysis. Similarly, matrix effects were minor in the case of olive oil (ca. 20% suppression average), while significantly higher suppression was observed for olives (30-50% suppression average). The studied approaches were found to be useful for the determination of the pesticides studied in olive oil and olives with limits of quantitation below 5µgkg(-1) in most cases when tandem mass spectrometry was used, thus being in compliance with MRLs set by current EU regulation. PMID:27343599

  4. Determination of polar pesticides in olive oil and olives by hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry and high resolution mass spectrometry.

    Science.gov (United States)

    Nortes-Méndez, Rocío; Robles-Molina, José; López-Blanco, Rafael; Vass, Andrea; Molina-Díaz, Antonio; Garcia-Reyes, Juan F

    2016-09-01

    This article reports the development of two HPLC-MS methods for the determination of polar pesticides in olive oil and olive samples by hydrophilic interaction liquid chromatography (HILIC) separation followed by mass spectrometry detection with tandem mass spectrometry using a triple quadrupole instrument operated in multiple reaction monitoring mode (HILIC-MS/MS) or electrospray time-of-flight mass spectrometry (HILIC-TOFMS). The selected polar pesticides included in the study were: amitrol, cyromazine, diquat, paraquat, mepiquat, trimethylsulfonium (trimesium, glyphosate counterion) and fosetyl aluminium. The simple sample treatment procedure was based on liquid partitioning with methanol. The performance of the sample extraction was evaluated in terms of recovery rates and matrix effects in both olive oil and olives matrices. The results obtained for olive oil were satisfactory while, due to the high complexity of olives, poor recovery rates were obtained for the extraction of diquat, paraquat and amitrol, although with a reasonable precision enabling its use in routine analysis. Similarly, matrix effects were minor in the case of olive oil (ca. 20% suppression average), while significantly higher suppression was observed for olives (30-50% suppression average). The studied approaches were found to be useful for the determination of the pesticides studied in olive oil and olives with limits of quantitation below 5µgkg(-1) in most cases when tandem mass spectrometry was used, thus being in compliance with MRLs set by current EU regulation.

  5. Liquid chromatography tandem mass spectrometry for measuring ¹³C-labeling in intermediates of the glycolysis and pentose phosphate pathway.

    Science.gov (United States)

    Cocuron, Jean-Christophe; Alonso, Ana Paula

    2014-01-01

    This chapter describes a procedure to analyze (13)C-labeled phosphorylated compounds by liquid chromatography tandem mass spectrometry. Phosphorylated compounds, intermediaries of the glycolysis and pentose phosphate pathway, are separated by anion exchange chromatography and their isotopic labeling is determined by mass spectrometry. A sensitivity in the fmole range is achieved using scheduled multiple reaction monitoring mode.

  6. Screening for estrogen residues in calf urine: Comparison of a validated yeast estrogen bioassay and gas chromatography-tandem mass spectrometry

    NARCIS (Netherlands)

    Nielen, M.W.F.; Bovee, T.F.H.; Heskamp, H.H.; Lasaroms, J.J.P.; Sanders, M.B.; Rhijn, van J.A.; Groot, M.J.; Hoogenboom, L.A.P.

    2006-01-01

    Within the European Union, the control for residues of illegal hormones in food-producing animals is based on urine analysis for a few target analytes using gas chromatography/mass spectrometry and/or liquid chromatography¿tandem mass spectrometry. Recently, we developed a robust yeast bioassay scre

  7. A simple and selective liquid chromatography- tandem mass spectrometry method for determination of ε-aminocaproic acid in human plasma

    Directory of Open Access Journals (Sweden)

    Ganesh S. Moorthy

    2015-07-01

    Full Text Available Understanding the clinical pharmacology of the antifibrinolytic drug epsilon-aminocaproic acid (EACA is critical for rational drug administration in children. The aim of this study is to develop a reliable assay for the determination of EACA in human plasma. We describe a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS assay for EACA in human plasma. Sample preparation involved plasma dilution (1:2040, followed by reversed-phase chromatographic separation and selective detection using tandem mass spectrometry. EACA had a linear range of 1 - 250 μg/mL. The intraday precision based on the standard deviation of replicates of quality control samples ranged from 4.7 to 10.4% and the accuracy ranged from 92-106%. The interday precision ranged from 4.6 to 9.8% and the accuracy ranged from 95-103%. Stability studies showed that EACA was stable during the conditions for sample preparation and storage. The described method is robust and successfully employed for clinical studies of EACA in children

  8. Determination of azithromycin residue in pork using a molecularly imprinted monolithic microcolumn coupled to liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Tong; Yang, Haicui; Jin, Zhen; Liu, Qingying; Song, Xuqin; He, Limin; Fang, Binghu; Meng, Chenying

    2016-04-01

    Using spiramycin as a dummy template, a molecularly imprinted polymer monolithic micro-column with high selection to azithromycin was prepared in a micropipette tip. The imprinting factor of the monolithic micro-column prepared was approximately 2.67 and the morphological structure of the polymers was characterized by scanning electron microscopy. A simple, sensitive, and reproducible method based on the imprinted monolithic micro-column coupled to liquid chromatography with tandem mass spectrometry was developed for determining the residues of azithromycin in pork. Pork samples were extracted with acetonitrile, cleaned up under the optimal monolithic micro-column conditions, and analyzed using liquid chromatography with tandem mass spectrometry in the multiple reaction monitoring mode. The assay exhibited a linear dynamic range of 0.50-50 μg/L with the correlation coefficient (r(2) ) above 0.99. In the three spiking levels of 0.50, 1.0, and 10 μg/kg, the average recoveries of azithromycin from pork samples were between 85.8 and 96.5% with a relative standard deviation below 10%. The limit of detection and limit of quantitation were 0.03 and 0.1 μg/kg, respectively. PMID:26854282

  9. Rapid Determination of Imatinib in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jeong Soo; Cho, Eun Gi; Huh, Wooseong; Ko, Jaewook; Jung, Jin Ah; Lee, Sooyoun [Samsung Medical Center, Seoul (Korea, Republic of)

    2013-08-15

    A simple, fast and robust analytical method was developed to determine imatinib in human plasma using liquid chromatography-tandem mass spectrometry with electrospray ionization in the positive ion mode. Imatinib and labeled internal standard were extracted from plasma with a simple protein precipitation. The chromatographic separation was performed using an isocratic elution of mobile phase involving 5.0 mM ammonium formate in water -5.0 mM ammonium formate in methanol (30:70, v/v) over 3.0 min on reversed-stationary phase. The detection was performed using a triple-quadrupole tandem mass spectrometer in multiple-reaction monitoring mode. The developed method was validated with lower limit of quantification of 10 ng/mL. The calibration curve was linear over 10-2000 ng/mL (R{sup 2} > 0.99). The method validation parameters met the acceptance criteria. The spiked samples and standard solutions were stable under conditions for storage and handling. The reliable method was successfully applied to real sample analyses and thus a pharmacokinetic study in 27 healthy Korean male volunteers.

  10. Simultaneous analysis of ten phytohormones in Sargassum horneri by high-performance liquid chromatography with electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Li, Yan; Zhou, Chengxu; Yan, Xiaojun; Zhang, Jinrong; Xu, Jilin

    2016-05-01

    Phytohormones have attracted wide attention due to their important biological functions. However, their detection is still a challenge because of their complex composition, low abundance and diverse sources. In this study, a novel method of high-performance liquid chromatography with electrospray ionization tandem mass spectrometry was developed and validated for the simultaneous determination of ten phytohormones including indole-3-acetic acid, isopentenyladenine, isopentenyl adenosine, trans-zeatin riboside, zeatin, strigolactones, abscisic acid, salicylic acid, gibberellin A3, and jasmonic acid in Sargassum horneri (S. horneri). The phytohormones were extracted from freeze-dried S. horneri with methanol/water/methanoic acid (15:4:1, v/v/v) analyzed on a Hypersil Gold C18 column and detected by electrospray ionization tandem triple quadrupole mass spectrometry in the multiple reaction monitoring mode. The experimental conditions for the extraction and analysis of phytohormones were optimized and validated in terms of reproducibility, linearity, sensitivity, recovery, accuracy, and stability. Distributions of the phytohormones in the stems, blades, and gas bladder of the S. horneri in drift, fixed, and semi-fixed growing states were investigated for the first time. The observed contents of the phytohormones in S. horneri range from not detected to 5066.67 ng/g (fresh weight). Most phytohormones are distributed mainly in the stems of S. horneri in drift and semi-fixed states. PMID:26990813

  11. High Performance Liquid Chromatography Tandem Mass Spectrometry Measurement of Bimatoprost, Latanoprost and Travoprost in Eyelash Enhancing Cosmetic Serums

    Directory of Open Access Journals (Sweden)

    Emilia Marchei

    2016-02-01

    Full Text Available Most common prostaglandin analogs, bimatoprost, latanoprost and travoprost, are licensed for the reduction of elevated intraocular pressure in patients with open angle glaucoma and ocular hypertension, but their non approved use as eyelash enhancers is becoming popular, especially in patients with eyelashes hypotrichosis. A fast and sensitive high performance liquid chromatography tandem mass spectrometry method was developed for the measurement of bimatoprost, latanoprost and travoprost in cosmetic serums freely web-sold to increase eyelash length, thickness and darkness. The analytes and the internal standard (reserpine were separated by reversed phase chromatography with 5 mM ammonium acetate with 0.02% formic acid (mobile phase A and 5 mM ammonium acetate in acetonitrile/water (95/5; v/v with 0.02% formic acid (mobile phase B by gradient elution and detected with tandem mass spectrometry operated in multiple reaction monitoring mode. Linearity between 1 and 500 μg/g shows good correlation coefficients (r2 = 0.99 for all substances. Analytical recovery of analytes under investigation were always higher than 90% and intra-assay and inter-assay precision and accuracy always better than 11%. This method was successfully applied to analyze cosmetic serums freely sold on the Internet websites.

  12. Sensitive liquid chromatography-tandem mass spectrometry method for the simultaneous determination of paracetamol and guaifenesin in human plasma.

    Science.gov (United States)

    Chen, Xiaoyan; Huang, Jia; Kong, Zhang; Zhong, Dafang

    2005-03-25

    A rapid and sensitive method for the simultaneous determination of paracetamol and guaifenesin in human plasma was developed and validated, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. After extracted from plasma samples by diethyl ether-dichloromethane (3:2, v/v), the analytes and internal standard osalmide were chromatographed on a C18 column. Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via atmospheric pressure chemical ionization (APCI). The method was linear in the concentration range of 0.05-20.0 microg/ml for paracetamol and 5.0-2000.0 ng/ml for guaifenesin. The intra- and inter-day precision was within 14% for both paracetamol and guaifenesin. The assay accuracy was within +/-2.4% for the analytes. This is the first assay method described for the simultaneous determination of paracetamol and guaifenesin in plasma using one chromatographic run. The method was successfully employed in a pharmacokinetic study after an oral administration of a multicomponent formulation, containing 650 mg paracetamol, 200 mg guaifenesin, 60 mg pseudoephedrine and 20 mg dextrorphan. PMID:15686994

  13. Analysis of triptophenolide and its related compounds from Tripterygium wilfordii Hook.f by electrospray ionization tandem mass spectrometry

    Science.gov (United States)

    Li, Rui; Peng, Aihua; He, Chunmei; Wang, Xianhuo; Shi, Jianyou; Chen, Lijuan; Wei, Yuquan

    2008-11-01

    Triptophenolide and its related compounds from Tripterygium wilfordii Hook.f is a kind of diterpenoids which shows anti-inflammatory activity. To study the metabolites of triptophenolide related compounds, the fragmentation mechanisms of them were investigated by using negative electrospray tandem mass spectrometry. With the aid of high resolution of ESI-QTOF-MS/MS, the fragmentation mechanisms of six diterpenoid compounds were systematically investigated. The fragmentation behavior mainly depends on what substituent groups the benzyl C ring bears. If there is a hydroxyl group on the position of C14, loss of CH4 is dominating. However, the successive loss of two CH3 radicals is predominant when the hydroxyl group of O14 is methylated. The lactone ring is prone to be dissociated to loss of CO, CO2 and C2H2O2 molecules. The pericyclic reaction can occur on A ring if there is an active hydrogen resides on C ring. Furthermore, one metabolite of compound A1 was confirmed by cytochrome P450 in vitro and the structure was proposed by tandem mass experiment together with the fragmentation mechanisms of this type of compounds.

  14. Characterization of oncogene-induced metabolic alterations in hepatic cells by using ultrahigh performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tang, Zhi; Cao, Tingting; Lin, Shuhai; Fu, Li; Li, Shangfu; Guan, Xin-Yuan; Cai, Zongwei

    2016-05-15

    Elucidation of altered metabolic pathways by using metabolomics may open new avenues for basic research on disease mechanisms and facilitate the development of novel therapeutic strategies. Here, we report the development of ultrahigh performance liquid chromatography-tandem mass spectrometry-based metabolomics platform with capability of measuring both cationic and anionic intermediates in cellular metabolism. The platform was established based on the hydrophobic ion-pairing interaction chromatography coupled with tandem mass spectrometry in multiple reaction monitoring (MRM) mode. The MRM transitions were created and optimized via energy-resolved collision-induced dissociation experiments, serving as an essential reference point for the quantification and identification. For chromatographic separation, application of hydrophobic ion-pairing interaction led to dramatic enhancement on retention of water-soluble metabolites and provision of good peak shapes. Two volatile ion-pairing reagents, namely heptafluorobutyric acid and tributylamine, were used with dedicated C18 columns as complementary separation systems coupled with the MRM analysis, allowing measurement of the metabolites of interest at nanomolar levels. The developed platform was successfully applied to investigate the altered metabolism in hepatic cells with over-expression of an oncogene, thus can provide important information on the rewired metabolism. PMID:26992502

  15. Identification of monomenthyl succinate, monomenthyl glutarate, and dimenthyl glutarate in nature by high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Hiserodt, Richard D; Adedeji, Jide; John, T V; Dewis, Mark L

    2004-06-01

    Menthol, menthone, and other natural compounds provide a cooling effect and a minty flavor and have found wide application in chewing gum and oral care products. Monomenthyl succinate, monomenthyl glutarate, and dimenthyl glutarate provide a cooling effect without the burning sensation associated with menthol. Additionally, because they do not have a distinct flavor, they can be used in applications other than mint flavors. Because these menthyl esters have not been reported in nature, we undertook to identify a natural source for these cooling compounds. Using high performance liquid chromatography-tandem mass spectrometry, monomenthyl succinate was identified in Lycium barbarum and Mentha piperita, and monomenthyl glutarate and dimenthyl glutarate were identified in Litchi chinesis. The identifications were based on the correlation of mass spectrometric and chromatographic retention time data for the menthyl esters in the extracts with authentic standards which resulted in a 99.980% confidence in the identifications.

  16. Analysis of the volatile compounds in Senecio scandens Buch-Ham by gas chromatography-tandem mass spectrometry based on diversified scan technologies.

    Science.gov (United States)

    Li, Sensen; Su, Yue; Guo, Yinlong

    2011-01-01

    Static headspace gas chromatography-tandem mass spectrometry was used to identify volatile compounds from Senecio scandens Buch-Ham. The elemental composition of compounds was confirmed by exploiting the tandem mass spectra of isotopic peaks from the precursor ion. Some isomers were well distinguished by the diversified scan technologies of tandem mass spectrometry (MS/MS). The MS/MS included a product ion scan, a precursor ion scan and a neutral loss scan. The results showed that 46 volatile compounds were completely identified, and the great of majority compounds were α-pinene (11.93%), n-caproaldehyde (9.02%) and dehydrosabinene (6.22%). This qualitative method is convenient and accurate and can be considered as a complementary identification method for the qualitative analysis of volatile compounds in complex samples. PMID:22006636

  17. Chiral liquid chromatography-mass spectrometry (LC-MS/MS) method development for the detection of salbutamol in urine samples.

    Science.gov (United States)

    Chan, Sue Hay; Lee, Warren; Asmawi, Mohd Zaini; Tan, Soo Choon

    2016-07-01

    A sequential solid-phase extraction (SPE) method was developed and validated using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) for the detection and quantification of salbutamol enantiomers in porcine urine. Porcine urine samples were hydrolysed with β-glucuronidase/arylsulfatase from Helix pomatia and then subjected to a double solid-phase extraction (SPE) first using the Abs-Elut Nexus SPE and then followed by the Bond Elut Phenylboronic Acid (PBA) SPE. The salbutamol enantiomers were separated using the Astec CHIROBIOTIC™ T HPLC column (3.0mm×100mm; 5μm) maintained at 15°C with a 15min isocratic run at a flow rate of 0.4mL/min. The mobile phase constituted of 5mM ammonium formate in methanol. Salbutamol and salbutamol-tert-butyl-d9 (internal standard, IS) was monitored and quantified with the multiple reaction monitoring (MRM) mode. The method showed good linearity for the range of 0.1-10ng/mL with limit of quantification at 0.3ng/mL. Analysis of the QC samples showed intra- and inter-assay precisions to be less than 5.04%, and recovery ranging from 83.82 to 102.33%. PMID:27232053

  18. Quantitative Mass Spectrometry for Bacterial Protein Toxins — A Sensitive, Specific, High-Throughput Tool for Detection and Diagnosis

    Directory of Open Access Journals (Sweden)

    Suzanne Kalb

    2011-03-01

    Full Text Available Matrix-assisted laser-desorption time-of-flight (MALDI-TOF mass spectrometry (MS is a valuable high-throughput tool for peptide analysis. Liquid chromatography electrospray ionization (LC-ESI tandem-MS provides sensitive and specific quantification of small molecules and peptides. The high analytic power of MS coupled with high-specificity substrates is ideally suited for detection and quantification of bacterial enzymatic activities. As specific examples of the MS applications in disease diagnosis and select agent detection, we describe recent advances in the analyses of two high profile protein toxin groups, the Bacillus anthracis toxins and the Clostridium botulinum neurotoxins. The two binary toxins produced by B. anthracis consist of protective antigen (PA which combines with lethal factor (LF and edema factor (EF, forming lethal toxin and edema toxin respectively. LF is a zinc-dependent endoprotease which hydrolyzes specific proteins involved in inflammation and immunity. EF is an adenylyl cyclase which converts ATP to cyclic-AMP. Toxin-specific enzyme activity for a strategically designed substrate, amplifies reaction products which are detected by MALDI-TOF-MS and LC-ESI-MS/MS. Pre-concentration/purification with toxin specific monoclonal antibodies provides additional specificity. These combined technologies have achieved high specificity, ultrasensitive detection and quantification of the anthrax toxins. We also describe potential applications to diseases of high public health impact, including Clostridium difficile glucosylating toxins and the Bordetella pertussis adenylyl cyclase.

  19. Stable Isotope Labeling Strategy for Curcumin Metabolite Study in Human Liver Microsomes by Liquid Chromatography-Tandem Mass Spectrometry

    Science.gov (United States)

    Gao, Dan; Chen, Xiaowu; Yang, Xiaomei; Wu, Qin; Jin, Feng; Wen, Hongliang; Jiang, Yuyang; Liu, Hongxia

    2015-04-01

    The identification of drug metabolites is very important in drug development. Nowadays, the most widely used methods are isotopes and mass spectrometry. However, the commercial isotopic labeled reagents are usually very expensive, and the rapid and convenient identification of metabolites is still difficult. In this paper, an 18O isotope labeling strategy was developed and the isotopes were used as a tool to identify drug metabolites using mass spectrometry. Curcumin was selected as a model drug to evaluate the established method, and the 18O labeled curcumin was successfully synthesized. The non-labeled and 18O labeled curcumin were simultaneously metabolized in human liver microsomes (HLMs) and analyzed by liquid chromatography/mass spectrometry (LC-MS). The two groups of chromatograms obtained from metabolic reaction mixture with and without cofactors were compared and analyzed using Metabolynx software (Waters Corp., Milford, MA, USA). The mass spectra of the newly appearing chromatographic peaks in the experimental sample were further analyzed to find the metabolite candidates. Their chemical structures were confirmed by tandem mass spectrometry. Three metabolites, including two reduction products and a glucuronide conjugate, were successfully detected under their specific HLMs metabolic conditions, which were in accordance with the literature reported results. The results demonstrated that the developed isotope labeling method, together with post-acquisition data processing using Metabolynx software, could be used for fast identification of new drug metabolites.

  20. Applying 'Sequential Windowed Acquisition of All Theoretical Fragment Ion Mass Spectra' (SWATH) for systematic toxicological analysis with liquid chromatography-high-resolution tandem mass spectrometry.

    Science.gov (United States)

    Arnhard, Kathrin; Gottschall, Anna; Pitterl, Florian; Oberacher, Herbert

    2015-01-01

    Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has become an indispensable analytical technique in clinical and forensic toxicology for detection and identification of potentially toxic or harmful compounds. Particularly, non-target LC-MS/MS assays enable extensive and universal screening requested in systematic toxicological analysis. An integral part of the identification process is the generation of information-rich product ion spectra which can be searched against libraries of reference mass spectra. Usually, 'data-dependent acquisition' (DDA) strategies are applied for automated data acquisition. In this study, the 'data-independent acquisition' (DIA) method 'Sequential Windowed Acquisition of All Theoretical Fragment Ion Mass Spectra' (SWATH) was combined with LC-MS/MS on a quadrupole-quadrupole-time-of-flight (QqTOF) instrument for acquiring informative high-resolution tandem mass spectra. SWATH performs data-independent fragmentation of all precursor ions entering the mass spectrometer in 21m/z isolation windows. The whole m/z range of interest is covered by continuous stepping of the isolation window. This allows numerous repeat analyses of each window during the elution of a single chromatographic peak and results in a complete fragment ion map of the sample. Compounds and samples typically encountered in forensic casework were used to assess performance characteristics of LC-MS/MS with SWATH. Our experiments clearly revealed that SWATH is a sensitive and specific identification technique. SWATH is capable of identifying more compounds at lower concentration levels than DDA does. The dynamic range of SWATH was estimated to be three orders of magnitude. Furthermore, the >600,000 SWATH spectra matched led to only 408 incorrect calls (false positive rate = 0.06 %). Deconvolution of generated ion maps was found to be essential for unravelling the full identification power of LC-MS/MS with SWATH. With the available software, however, only semi

  1. Determination of capsaicin, dihydrocapsaicin, and nonivamide in self-defense weapons by liquid chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Reilly, C A; Crouc, D J; Yost, G S; Fatah, A A

    2001-04-01

    Sensitive and selective liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) methods for the analysis of capsaicin, dihydrocapsaicin, and nonivamide in pepper spray products have been developed. Chromatographic separation of the capsaicinoid analogues was achieved using a reversed-phase HPLC column and a stepwise gradient of methanol and distilled water containing 0.1% (v/v) formic acid. Identification and quantification of the capsaicinoids was achieved by electrospray ionization single-stage mass spectrometry monitoring the protonated molecules of the internal standard (m/z 280), capsaicin (m/z 306), dihydrocapsaicin (m/z 308), and nonivamide (m/z 294) or by tandem mass spectrometry monitoring the appropriate precursor-to-product-ion transitions. The plot of concentration versus peak area ratio was linear over the range of 10-750 ng/ml using LC-MS and 10-500 ng/ml using LC-MS-MS. However, to accurately quantify the capsaicinoids in the pepper spray products calibration curves between 10 and 1000 ng were constructed and fit using a weighted quadratic equation. Using the quadratic curve, the accuracy of the assay ranged from 91 to 102% for all analytes. The intra-assay precision (RSD) for capsaicin was 2% at 25 ng/ml, 10% at 500 ng/ml, and 3% at 800 ng/ml. The inter-assay precision (RSD) for capsaicin was 6% at 25 ng/ml, 6% at 500 ng/ml, and 9% at 800 ng/ml. Similar values for inter- and intra-assay precision were experimentally obtained for both dihydrocapsaicin and nonivamide. The analysis of selected pepper spray products demonstrated that the capsaicinoid concentration in the products ranged from 0.7 to 40.5 microg/microl. PMID:11330795

  2. Quantification of antidepressants and antipsychotics in human serum by precipitation and ultra high pressure liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Hasselstrøm, Jørgen Bo

    2011-01-01

    precipitated with zinc sulphate and methanol containing a stable isotope labelled analog for each analyte. Quantitative analysis was performed by ultra high pressure liquid chromatography combined with a tandem mass spectrometer using a Zorbax SB-C8 column (2.0×50mm; 1.8m) with a mobile phase consisting of 0.......1% formic acid in water and methanol, respectively. The total run time of the chromatography was 4 min. Precision and trueness varied from 2.6% to 14.9% and 87.6% to 103.5%, respectively. At the lower limit of quantification, precision was up to 17.9% and trueness varied from 89.5% to 111.5%. A five point...

  3. In vivo and in vitro metabolism of aspirin eugenol ester in dog by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Shen, Youming; Liu, Xiwang; Yang, Yajun; Li, Jianyong; Ma, Ning; Li, Bing

    2015-01-01

    Aspirin eugenol ester (AEE) is a promising drug candidate for treatment of inflammation, pain and fever and prevention of cardiovascular diseases with fewer side effects than its precursor, aspirin. Investigation into its metabolic process in target animal species will help to illustrate its mechanism of action and to establish its residual mark compound to formulate its dosage. Six beagle dogs were orally given a dose of 20 mg kg(-1) of AEE and one dog was used to prepare blank liver microsomes. Their liver microsomes were prepared for in vitro study and their plasma and urine were collected for in vivo metabolic analysis using liquid chromatography tandem mass spectrometry. In this study we identified 10 metabolites, M1, M2, M3, M4, M5 in phase I and M6, M7, M8, M9, M10 in phase II. Based on the metabolites of AEE, the pathways of AEE metabolism in dog were demonstrated.

  4. Analysis of 10 systemic pesticide residues in various baby foods using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Yang, Angel; Abd El-Aty, A M; Park, Jong-Hyouk; Goudah, Ayman; Rahman, Md Musfiqur; Do, Jung-Ah; Choi, Ok-Ja; Shim, Jae-Han

    2014-06-01

    Ten systemic pesticides, comprising methomyl, thiamethoxam, acetamiprid, carbofuran, fosthiazate, metalaxyl, azoxystrobin, diethofencarb, propiconazole, and difenoconazole, were detected in 13 baby foods (cereals, boiled potatoes, fruit and milk) using QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) for sample preparation and liquid chromatography tandem mass spectrometry for analysis. The matrix-matched calibration curves showed good linearity with determination coefficients (R(2) ) >0.992. The limits of detection and quantitation were 0.0015-0.003 and 0.005-0.01 mg/kg, respectively. The mean recoveries of three different concentrations ranged from 69.2 to 127.1% with relative standard deviations pesticide residues. This method is suitable for the identification and quantification of systemic pesticides with matrix-matched standards in various baby foods. PMID:24861738

  5. Detection of lysergic acid diethylamide (LSD) in urine by gas chromatography-ion trap tandem mass spectrometry.

    Science.gov (United States)

    Sklerov, J H; Kalasinsky, K S; Ehorn, C A

    1999-10-01

    A confirmatory method for the detection and quantitation of lysergic acid diethylamide (LSD) is presented. The method employs gas chromatography-tandem mass spectrometry (GC-MS-MS) using an internal ionization ion trap detector for sensitive MS-MS-in-time measurements of LSD extracted from urine. Following a single-step solid-phase extraction of 5 mL of urine, underivatized LSD can be measured with limits of quantitation and detection of 80 and 20 pg/mL, respectively. Temperature-programmed on-column injections of urine extracts were linear over the concentration range 20-2000 pg/mL (r2 = 0.999). Intraday and interday coefficients of variation were LSD-positive samples in this laboratory. Comparisons with alternate GC-MS methods and extraction procedures are discussed.

  6. Development, validation and determination of multiclass pesticide residues in cocoa beans using gas chromatography and liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Zainudin, Badrul Hisyam; Salleh, Salsazali; Mohamed, Rahmat; Yap, Ken Choy; Muhamad, Halimah

    2015-04-01

    An efficient and rapid method for the analysis of pesticide residues in cocoa beans using gas and liquid chromatography-tandem mass spectrometry was developed, validated and applied to imported and domestic cocoa beans samples collected over 2 years from smallholders and Malaysian ports. The method was based on solvent extraction method and covers 26 pesticides (insecticides, fungicides, and herbicides) of different chemical classes. The recoveries for all pesticides at 10 and 50 μg/kg were in the range of 70-120% with relative standard deviations of less than 20%. Good selectivity and sensitivity were obtained with method limit of quantification of 10 μg/kg. The expanded uncertainty measurements were in the range of 4-25%. Finally, the proposed method was successfully applied for the routine analysis of pesticide residues in cocoa beans via a monitoring study where 10% of them was found positive for chlorpyrifos, ametryn and metalaxyl. PMID:25442595

  7. The use of liquid chromatography tandem mass spectrometry to detect proteins in saliva from horses with and without systemic inflammation.

    Science.gov (United States)

    Jacobsen, Stine; Top Adler, Ditte Marie; Bundgaard, Louise; Sørensen, Mette Aamand; Andersen, Pia Haubro; Bendixen, Emøke

    2014-12-01

    The objective of the study was to assess global expression of proteins in equine saliva using liquid chromatography tandem mass spectrometry (LC-MS/MS). Saliva was obtained from seven horses with and six horses without evidence of systemic inflammatory disease. Tryptic peptides from saliva were analysed by LC-MS/MS. Of 195 unique proteins identified, 57 were detected only in saliva samples from horses with systemic inflammation (in two to six of the seven horses). Among the differentially expressed proteins were several acute phase proteins (APPs) such as serum amyloid A, fibrinogen, haptoglobin, and alpha1-acid glycoprotein. The study is the first to describe detection of inflammatory proteins in horse saliva. The proteins detected were similar to those described in saliva from cattle, small ruminants and pigs. Detection of APPs in horses with systemic inflammation suggests that saliva may be used for non-invasive disease monitoring in horses as in humans, pigs and dogs. PMID:25296850

  8. The use of liquid chromatography tandem mass spectrometry to detect proteins in saliva from horses with and without systemic inflammation

    DEFF Research Database (Denmark)

    Jacobsen, Stine; Top Adler, Ditte Marie; Bundgaard, Louise;

    2014-01-01

    The objective of the study was to assess global expression of proteins in equine saliva using liquid chromatography tandem mass spectrometry (LC-MS/MS). Saliva was obtained from seven horses with and six horses without evidence of systemic inflammatory disease. Tryptic peptides from saliva were...... analysed by LC-MS/MS. Of 195 unique proteins identified, 57 were detected only in saliva samples from horses with systemic inflammation (in two to six of the seven horses). Among the differentially expressed proteins were several acute phase proteins (APPs) such as serum amyloid A, fibrinogen, haptoglobin......, and alpha1-acid glycoprotein. The study is the first to describe detection of inflammatory proteins in horse saliva. The proteins detected were similar to those described in saliva from cattle, small ruminants and pigs. Detection of APPs in horses with systemic inflammation suggests that saliva may be...

  9. Liquid chromatography-tandem mass spectrometry determination of synthetic cathinones and phenethylamines in influent wastewater of eight European cities

    DEFF Research Database (Denmark)

    Bade, Richard; Bijlsma, Lubertus; Sancho, Juan V.;

    2016-01-01

    The popularity of new psychoactive substances (NPS) has grown in recent years, with certain NPS commonly and preferentially consumed even following the introduction of preventative legislation. With the objective to improve the knowledge on the use of NPS, a rapid and very sensitive method...... (SPE) with Oasis MCX cartridges. Isotopically labelled internal standards were used to correct for matrix effects and potential SPE losses. Following chromatographic separation on a C18 column within 6 min, the compounds were measured by tandem mass spectrometry in positive ionization mode. The method...... relatively stable for up to 7 days. The method was then applied to influent wastewater samples from eight European countries, in which mephedrone, methylone and MDPV were detected. This work reveals that although NPS use is not as extensive as for classic illicit drugs, the application of a highly sensitive...

  10. Characterisation of honeys according to their content of phenolic compounds using high performance liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Sergiel, Iwona; Pohl, Pawel; Biesaga, Magdalena

    2014-02-15

    A simple, fast and specific high performance liquid chromatography separation with an electro-spray ionisation tandem mass spectrometry detection in a negative single reaction ion monitoring scan mode was developed and used for the characterization of Polish honeys according to the content of phenolic acids, including caffeic, chlorogenic, p-coumaric, ferulic, homogentisic, p-hydroxybenzoic and vanillic acids, and flavonoids, i.e., apigenin, genistein, hesperetin, kaempferol, luteolin, rhamnetin, rutin, tricetin and quercetin. Target compounds were isolated and pre-concentrated from the honey matrix by means of the solid phase extraction using Strata X (500mg) cartridges. Analysed honeys did not contain tricetin and genistein. Hesperetin was determined for the first time in heather and linden honeys while rutin in rape honey. PMID:24128495

  11. Development and evaluation of a liquid chromatography tandem mass spectrometry method for simultaneous determination of salivary melatonin, cortisol and testosterone

    DEFF Research Database (Denmark)

    Jensen, Marie Aarrebo; Hansen, Åse Marie; Abrahamsson, Peter;

    2011-01-01

    saliva. We used liquid-liquid extraction (LLE) followed by liquid chromatography coupled to electrospray tandem mass spectrometry (LC-ESI-MS/MS) recorded in positive ion mode. Saliva samples were collected by spitting directly into tubes and 250 µL were used for analysis. The limits of detection were 4......Circadian disruption can have several possible health consequences, but is not well studied. In order to measure circadian disruption, in relation to shift or night work, we developed a simple and sensitive method for the simultaneous determination of melatonin, cortisol and testosterone in human.......1 pmol/L, 0.27 nmol/L and 10.8 pmol/L for melatonin, cortisol, and testosterone, respectively. The developed method was sensitive enough to measure circadian rhythms of all 3 hormones in a pilot study among four healthy volunteers. It can therefor be used to study the impact of night work and working...

  12. Determination of seven bisphenol analogues in reed and Callitrichaceae by ultra performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lu, Libin; Yang, Yunjia; Zhang, Jing; Shao, Bing

    2014-03-15

    An analytical procedure was developed to simultaneously determine bisphenol S, bisphenol F, bisphenol B, bisphenol A, bisphenol AF, tetrachlorobisphenol A, and tetrabromobisphenol A in reed and Callitrichaceae. Homogenized samples were extracted with acetonitrile and purified using an ENVI™-Carb cartridge followed by an NH2 cartridge. The analytes were separated and quantified by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The recoveries at three fortified levels in reed and Callitrichaceae were 57-108% and 68-106%, respectively, with relative standard deviations of no more than 15% (n=6). The method limits of quantification and detection for the seven bisphenol analogues were 0.005-0.500μg/kg and 0.002-0.150μg/kg, respectively. This method was used to analyze the seven compounds in ten reed and Callitrichaceae samples collected from Zhejiang, China.

  13. Rapid determination of vitamin D₃ in milk-based infant formulas by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kwak, Byung-Man; Jeong, In-Seek; Lee, Moon-Seok; Ahn, Jang-Hyuk; Park, Jong-Su

    2014-12-15

    A rapid and simple sample preparation method for vitamin D3 (cholecalciferol) was developed for emulsified dairy products such as milk-based infant formulas. A sample was mixed in a 50 mL centrifuge tube with the same amount of water and isopropyl alcohol to achieve chemical extraction. Ammonium sulfate was used to induce phase separation. No-heating saponification was performed in the sample tube by adding KOH, NaCl, and NH3. Vitamin D3 was then separated and quantified using liquid chromatography-tandem mass spectrometry. The results for added recovery tests were in the range 93.11-110.65%, with relative standard deviations between 2.66% and 2.93%. The results, compared to those obtained using a certified reference material (SRM 1849a), were within the range of the certificated values. This method could be implemented in many laboratories that require time and labour saving.

  14. [Simultaneous determination of six synthetic sweeteners in food by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Liu, Xiaoxi; Ding, Li; Liu, Jinxia; Zhang, Ying; Huang, Zhiqiang; Wang, Libing; Chen, Bo

    2010-11-01

    A simple and sensitive method for the determination of six synthetic sweeteners (sodium cyclamate, saccharin sodium, acesulfame-K, aspartame, alitame and neotame) in food was developed. The synthetic sweeteners were extracted by methanol-water (1 : 1, v/v). The extract was separated on a C18 column using 0.1% (v/v) formic acid-5 mmol/L ammonium formate/acetonitrile as mobile phase, and then detected by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) using multiple reaction monitoring (MRM) mode. The good linearities (r > 0.998) were achieved for all the analytes over the range of 20-500 microg/L. The recoveries obtained ranged from 81.3% to 106.0% at three spiked concentrations, with the relative standard deviations lower than 11%. The established method has been successfully applied to the determination of synthetic sweeteners in food. PMID:21381416

  15. Modernization of Chinese herbal compound and the high performance liquid chromatography tandem mass spectrometry (HPLC-MS)

    Institute of Scientific and Technical Information of China (English)

    LI Wen-lan; SUN Zhi; DU Juan

    2008-01-01

    Chinese herbal compound is playing an important role on curing human diseases. And it has been a trend that Chinese herbal compound is being used all over the world in 21 century. However, our Chinese herbal compound is facing serious challenge for the lack of canonical system of quality criterion for Chinese herbal compound so it has been a urgent problem to set up the quality control standards and reveal therapeutic basis of Chinese herbal compound. In order to give full play to the advantages of Chinese herbal compound, modern scientific and technological is used to research of Chinese herbal compound, especially the high performance liquid chromatography tandem mass spectrometry(HPLC-MS), because it is high sensitive, rapid, and obtain more information. It is very necessary that HPLC-MS is uesed to elucidate the effective components of basic substances of Chinese Herbal Compound, and endow traditional Chinese medicine with modern scientific connotation.

  16. Affinity labeling coupled with matrix assistant laser desorption tandem time of flight mass spectrometry for quantitative proteomies research

    Institute of Scientific and Technical Information of China (English)

    MENG Qingfang; ZHANG Yangjun; CAI Yun; QIAN Xiaohong

    2007-01-01

    A relative quantitative method for differential proteomics by cleavable isotope-coded atTmity tag (cICAT)and matrix-assisted laser desorption/ionization tandem time-of-flight mass spectrometry (MALDI-TOF-MS) was estab-lished. The accuracy and reproducibility of the method were evaluated by bovine serum albumin (BSA) digest as having a relative standard deviation of less than 30% and good reproducibility. The dynamic range was als0 evaluated by analyzing two mixtures of several standard proteins with dif-ferent concentration. The experimental results showed that in the dynamic range of 1:30, the quantitation error of the method was less than 30%. Although the quantitation error becomes very large when used beyond this range, it does not affect the derivation of information on the differential proteins. All the work provides an alternative method for differential proteomics analysis in biological samples from different origins.

  17. Accelerator mass spectrometry of 63Ni using a gas-filled magnet at the Munich Tandem Laboratory

    Science.gov (United States)

    Rugel, G.; Faestermann, T.; Knie, K.; Korschinek, G.; Marchetti, A. A.; McAninch, J. E.; Rühm, W.; Straume, T.; Wallner, C.

    2000-10-01

    The detection of 63Ni ( T1/2=100.1 yr) by means of accelerator mass spectrometry (AMS) using a gas-filled magnet (GFM) is described. The experimental setup includes a dedicated ion source, a 14 MV MP tandem, a GFM and a multi-anode ionization chamber. First results indicate a background level of 63Ni/Ni ratios as low as 2×10 -14. This sensitivity will allow - for the first time ever - to detect 63Ni induced by fast neutrons in copper samples from Hiroshima and Nagasaki, even for distances beyond 1500 m from the hypocenters. Thus, it will be possible to reconstruct experimentally the neutron doses of the A-bomb survivors from Hiroshima and Nagasaki.

  18. Determination of cholesterol and four phytosterols in foods without derivatization by gas chromatography-tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Yan-Zong Chen

    2015-12-01

    Full Text Available In this study, a method for determination of cholesterol and four phytosterols by gas chromatography coupled with electron impact ionization mode–tandem mass spectrometry without derivatization in general food was developed. The sample was saponified with 7.5% KOH in methanol. After heating on hot plate and reflux for 60 minutes, the saponified portion was extracted with n-hexane/petroleum ether (50:50, v/v. The extracts were evaporated with rotary evaporator and then redissolved with tetrahydrofuran. The tetrahydrofuran layer was transferred into an injection vial and analyzed by gas chromatography on a 30 m VF-5 column. Limit of quantification was 2 mg/kg. Recoveries of cholesterol and four phytosterols from general food were between 91% and 100%.

  19. Development of rapid determination of 18 phthalate esters in edible vegetable oils by gas chromatography tandem mass spectrometry.

    Science.gov (United States)

    Liu, Yinping; Wang, Shuhui; Wang, Li

    2013-02-13

    A simultaneous and fast determination of 18 phthalic acid esters (PAEs) in edible vegetable oils was developed. After solvent extraction, the PAEs in the oil sample were further cleaned up by solid-phase extraction. After concentration, the extract was directly injected into gas chromatography tandem mass spectrometry (GC-MS/MS) in positive-ion electron impact (EI) mode. Method quantification limits of 18 PAEs were between 0.01 and 0.1 mg/kg. Quantitative recoveries ranging from 63.9 to 115.3% were obtained by analysis of spiked oil. The relative standard deviations were less than 15% (n = 6). The method could potentially overcome the interference from large amounts of lipids and pigment. It was applied to real sample and shown to be a rapid and reliable alternative for determination and confirmation of PAEs in routine analysis. PMID:23339279

  20. Determining the Binding Sites of β-Cyclodextrin and Peptides by Electron-Capture Dissociation High Resolution Tandem Mass Spectrometry

    Science.gov (United States)

    Qi, Yulin; Geib, Timon; Volmer, Dietrich A.

    2015-07-01

    Cyclodextrins (CDs) are a group of cyclic oligosaccharides, which readily form inclusion complexes with hydrophobic compounds to increase bioavailability, thus making CDs ideal drug excipients. Recent studies have also shown that CDs exhibit a wide range of protective effects, preventing proteins from aggregation, degradation, and folding. These effects strongly depend on the binding sites on the protein surface. CDs only exhibit weak interactions with amino acids, however; conventional analytical techniques therefore usually fail to reveal the exact location of the binding sites. Moreover, some studies even suggest that CD inclusion complexes are merely electrostatic adducts. Here, electron capture dissociation (ECD) was applied in this proof-of-concept study to examine the exact nature of the CD/peptide complexes, and CD binding sites were unambiguously located for the first time via Fourier-transform ion cyclotron resonance (FTICR) tandem mass spectrometry.

  1. Detection and Characterization of Non-covalent Complex between Lappaconitine and β-Cyclodextrin by Electrospray Ionization Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    Qing Xuan XU; Li LI; Hao YUE; Zhi Qiang LIU; Ming Quan GUO; Shu Ying LIU

    2006-01-01

    The non-covalent complexes between lappaconitine (LA) and β-cyclodextrin (β-CD) have been detected and characterized by electrospray ionization combined with ion trap tandem mass spectrometry (ESI-MSn). The experimental results showed that only 1:1 non-covalent complex can be formed in different starting molar ratios of LA to β-CD. Furthermore, the diagnostic fragmentation of the β-CD-LA complex, with a significant contribution of covalent fragmentation of LA leaving the N-acetyl anthranoyl (AN) moiety inserted to β-CD, provided the convincing evidence for the formation of non-covalent complex between LA and β-CD and the cite of LA molecule included to cavity of β-CD assigned to AN residue.

  2. Analysis of perchlorate, thiocyanate, nitrate and iodide in human amniotic fluid using ion chromatography and electrospray tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Blount, Benjamin C. [Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341 (United States)]. E-mail: bblount@cdc.gov; Valentin-Blasini, Liza [Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341 (United States)

    2006-05-10

    Because of health concerns surrounding in utero exposure to perchlorate, we developed a sensitive and selective method for quantifying iodide, as well as perchlorate and other sodium-iodide symporter (NIS) inhibitors in human amniotic fluid using ion chromatography coupled with electrospray ionization tandem mass spectrometry. Iodide and NIS inhibitors were quantified using a stable isotope-labeled internal standards (Cl{sup 18}O{sub 4} {sup -}, S{sup 13}CN{sup -} and {sup 15}NO{sub 3} {sup -} with excellent assay accuracy of 100%, 98%, 99%, 95% for perchlorate, thiocyanate, nitrate and iodide, respectively, in triplicate analysis of spiked amniotic fluid sample). Excellent analytical precision (<5.2% RSD for all analytes) was found when amniotic fluid quality control pools were repetitively analyzed for iodide and NIS-inhibitors. Selective chromatography and tandem mass spectrometry reduced the need for sample cleanup, resulting in a rugged and rapid method capable of routinely analyzing 75 samples/day. Analytical response was linear across the physiologically relevant concentration range for the analytes. Analysis of a set of 48 amniotic fluid samples identified the range and median levels for perchlorate (0.057-0.71, 0.18 {mu}g/L), thiocyanate (<10-5860, 89 {mu}g/L), nitrate (650-8900, 1620 {mu}g/L) and iodide (1.7-170, 8.1 {mu}g/L). This selective, sensitive, and rapid method will help assess exposure of the developing fetus to low levels of NIS-inhibitors and their potential to inhibit thyroid function.

  3. [Qualitative and quantitative analysis of amygdalin and its metabolite prunasin in plasma by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry].

    Science.gov (United States)

    Gao, Meng; Wang, Yuesheng; Wei, Huizhen; Ouyang, Hui; He, Mingzhen; Zeng, Lianqing; Shen, Fengyun; Guo, Qiang; Rao, Yi

    2014-06-01

    A method was developed for the determination of amygdalin and its metabolite prunasin in rat plasma after intragastric administration of Maxing shigan decoction. The analytes were identified by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and quantitatively determined by ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry. After purified by liquid-liquid extraction, the qualitative analysis of amygdalin and prunasin in the plasma sample was performed on a Shim-pack XR-ODS III HPLC column (75 mm x 2.0 mm, 1.6 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on a Triple TOF 5600 quadrupole time of flight mass spectrometer. The quantitative analysis of amygdalin and prunasin in the plasma sample was performed by separation on an Agilent C18 HPLC column (50 mm x 2.1 mm, 1.7 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on an AB Q-TRAP 4500 triple quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operated in negative ion mode and multiple-reaction monitoring (MRM) mode. The qualitative analysis results showed that amygdalin and its metabolite prunasin were detected in the plasma sample. The quantitative analysis results showed that the linear range of amygdalin was 1.05-4 200 ng/mL with the correlation coefficient of 0.999 0 and the linear range of prunasin was 1.25-2 490 ng/mL with the correlation coefficient of 0.997 0. The method had a good precision with the relative standard deviations (RSDs) lower than 9.20% and the overall recoveries varied from 82.33% to 95.25%. The limits of detection (LODs) of amygdalin and prunasin were 0.50 ng/mL. With good reproducibility, the method is simple, fast and effective for the qualitative and quantitative analysis of the amygdalin and prunasin in plasma sample of rats which were administered by Maxing shigan decoction.

  4. De Novo Correction of Mass Measurement Error in Low Resolution Tandem MS Spectra for Shotgun Proteomics

    Science.gov (United States)

    Egertson, Jarrett D.; Eng, Jimmy K.; Bereman, Michael S.; Hsieh, Edward J.; Merrihew, Gennifer E.; MacCoss, Michael J.

    2012-12-01

    We report an algorithm designed for the calibration of low resolution peptide mass spectra. Our algorithm is implemented in a program called FineTune, which corrects systematic mass measurement error in 1 min, with no input required besides the mass spectra themselves. The mass measurement accuracy for a set of spectra collected on an LTQ-Velos improved 20-fold from -0.1776 ± 0.0010 m/z to 0.0078 ± 0.0006 m/z after calibration (avg ± 95 % confidence interval). The precision in mass measurement was improved due to the correction of non-linear variation in mass measurement accuracy across the m/z range.

  5. Arsenic speciation by liquid chromatography coupled with ionspray tandem mass spectrometry

    DEFF Research Database (Denmark)

    Corr, J. J.; Larsen, Erik Huusfeldt

    1996-01-01

    Ionspray mass spectrometry, a well established organic analysis technique, has been coupled to high-performance liquid chromatography for speciation of organic arsenic compounds, The ionspray source and differentially pumped interface of the mass spectrometer were operated in dual modes...... fragmentation patterns showing molecular dissociation through an expected common product ion were obtained for the four arsenosugars, Molecular mode detection was utilized for qualitative verification of speciation analysis by high-performance liquid chromatography coupled to inductively coupled plasma mass...

  6. Cloud-point extraction is compatible with liquid chromatography coupled to electrospray ionization mass spectrometry for the determination of antazoline in human plasma.

    Science.gov (United States)

    Giebułtowicz, Joanna; Kojro, Grzegorz; Piotrowski, Roman; Kułakowski, Piotr; Wroczyński, Piotr

    2016-09-01

    Cloud-point extraction (CPE) is attracting increasing interest in a number of analytical fields, including bioanalysis, as it provides a simple, safe and environmentally-friendly sample preparation technique. However, there are only few reports on the application of this extraction technique in liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis. In this study, CPE was used for the isolation of antazoline from human plasma. To date, only one method of antazoline isolation from plasma exists-liquid-liquid extraction (LLE). The aim of this study was to prove the compatibility of CPE and LC-ESI-MS/MS and the applicability of CPE to the determination of antazoline in spiked human plasma and clinical samples. Antazoline was isolated from human plasma using Triton X-114 as a surfactant. Xylometazoline was used as an internal standard. NaOH concentration, temperature and Triton X-114 concentration were optimized. The absolute matrix effect was carefully investigated. All validation experiments met international acceptance criteria and no significant relative matrix effect was observed. The compatibility of CPE and LC-ESI-MS/MS was confirmed using clinical plasma samples. The determination of antazoline concentration in human plasma in the range 10-2500ngmL(-1) by the CPE method led to results which are equivalent to those obtained by the widely used liquid-liquid extraction method. PMID:27289300

  7. Cloud-point extraction is compatible with liquid chromatography coupled to electrospray ionization mass spectrometry for the determination of antazoline in human plasma.

    Science.gov (United States)

    Giebułtowicz, Joanna; Kojro, Grzegorz; Piotrowski, Roman; Kułakowski, Piotr; Wroczyński, Piotr

    2016-09-01

    Cloud-point extraction (CPE) is attracting increasing interest in a number of analytical fields, including bioanalysis, as it provides a simple, safe and environmentally-friendly sample preparation technique. However, there are only few reports on the application of this extraction technique in liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis. In this study, CPE was used for the isolation of antazoline from human plasma. To date, only one method of antazoline isolation from plasma exists-liquid-liquid extraction (LLE). The aim of this study was to prove the compatibility of CPE and LC-ESI-MS/MS and the applicability of CPE to the determination of antazoline in spiked human plasma and clinical samples. Antazoline was isolated from human plasma using Triton X-114 as a surfactant. Xylometazoline was used as an internal standard. NaOH concentration, temperature and Triton X-114 concentration were optimized. The absolute matrix effect was carefully investigated. All validation experiments met international acceptance criteria and no significant relative matrix effect was observed. The compatibility of CPE and LC-ESI-MS/MS was confirmed using clinical plasma samples. The determination of antazoline concentration in human plasma in the range 10-2500ngmL(-1) by the CPE method led to results which are equivalent to those obtained by the widely used liquid-liquid extraction method.

  8. Cloud-point extraction is compatible with liquid chromatography coupled to electrospray ionization mass spectrometry for the determination of bisoprolol in human plasma.

    Science.gov (United States)

    Giebułtowicz, Joanna; Kojro, Grzegorz; Buś-Kwaśnik, Katarzyna; Rudzki, Piotr J; Marszałek, Ryszard; Leś, Andrzej; Wroczyński, Piotr

    2015-12-01

    Cloud-point extraction (CPE) draws increasing interest in a number of analytical fields including bioanalysis, but combining CPE and LC-MS with electrospray ionization (ESI) in the determination of drugs in biological fluids such as plasma, serum or blood has not been reported so far. Bisoprolol was determined in human plasma by CPE using Trition X-114 as a surfactant and metoprolol as the internal standard. NaOH concentration, temperature and Trition X-114 concentration were optimized. All analyses were performed using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS). All validation experiments met international acceptance criteria and no significant matrix effect was observed. The compatibility of CPE and LC-ESI-MS/MS was confirmed using clinical plasma samples and appropriate statistical tests. The determination of bisoprolol concentration in human plasma in the range 1.0-70ngmL(-1) by the CPE method leads to the results which are equivalent to those obtained by the widely used liquid-liquid extraction method. The results revealed that a structural analogue may be an appropriate internal standard when CPE is used as the extraction technique. CPE offers significant practical advantages over the classical extraction methods, including a positive impact on the environment, therefore its wider application in future pharmacokinetic studies is justifiable.

  9. Simultaneous determination of levophencynonate and its metabolite demethyl levophencynonate in human plasma by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Li, Bo; Qi, Wenyuan; Shi, Aixin; Hu, Xin; Cheng, Gang

    2016-08-01

    A sensitive and convenient high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method was developed to determine levophencynonate and demethyl levophencynonate levels in human plasma simultaneously. Chromatographic separation was achieved on a SHIMADZU Shim-Pack XR C8 column and mass spectrometric analysis was performed by an API5000 mass spectrometer coupled with an electro-spray ionization (ESI) source in the positive ion mode. The MRM transitions of m/z 358.4→156.4 and 344.5→144.2 were used to quantify levophencynonate and demethyl levophencynonate, respectively. This analytical method was fully validated with specificity, linearity, lower limit of quantitation (LLOQ), accuracy, precision, stability, matrix effect and recovery. The linearity of this method were developed to be within the concentration ranges of 10-4000pg/mL for levophencynonate and 25-8000pg/mL for demethyl levophencynonate in human plasma. This method was used in a clinical study which was administrated with single oral dose for Chinese healthy subjects to investigate the pharmacokinetics of levophencynonate and demethyl levophencynonate. PMID:27304783

  10. Enantioselective simultaneous analysis of selected pharmaceuticals in environmental samples by ultrahigh performance supercritical fluid based chromatography tandem mass spectrometry.

    Science.gov (United States)

    Camacho-Muñoz, Dolores; Kasprzyk-Hordern, Barbara; Thomas, Kevin V

    2016-08-31

    In order to assess the true impact of each single enantiomer of pharmacologically active compounds (PACs) in the environment, highly efficient, fast and sensitive analytical methods are needed. For the first time this paper focuses on the use of ultrahigh performance supercritical fluid based chromatography coupled to a triple quadrupole mass spectrometer to develop multi-residue enantioselective methods for chiral PACs in environmental matrices. This technique exploits the advantages of supercritical fluid chromatography, ultrahigh performance liquid chromatography and mass spectrometry. Two coated modified 2.5 μm-polysaccharide-based chiral stationary phases were investigated: an amylose tris-3,5-dimethylphenylcarbamate column and a cellulose tris-3-chloro-4-methylphenylcarbamate column. The effect of different chromatographic variables on chiral recognition is highlighted. This novel approach resulted in the baseline resolution of 13 enantiomers PACs (aminorex, carprofen, chloramphenicol, 3-N-dechloroethylifosfamide, flurbiprofen, 2-hydroxyibuprofen, ifosfamide, imazalil, naproxen, ofloxacin, omeprazole, praziquantel and tetramisole) and partial resolution of 2 enantiomers PACs (ibuprofen and indoprofen) under fast-gradient conditions (chromatography coupled with tandem mass spectrometry. PMID:27506366

  11. Determination of rutin in rat plasma by ultra performance liquid chromatography tandem mass spectrometry and application to pharmacokinetic study.

    Science.gov (United States)

    Chen, Mengchun; Zhang, Xiaoqian; Wang, Hao; Lin, Baoli; Wang, Shuanghu; Hu, Guoxin

    2015-04-01

    A sensitive and rapid ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS-MS) method for the determination of rutin in rat plasma was developed and validated. After addition of tolbutamide as internal standard (IS), protein precipitation by acetonitrile was used as sample preparation. The chromatographic separation was performed on an Acquity UPLC BEH C18 column (2.1 × 50 mm, 1.7 μm particle size), using acetonitrile-0.1% formic acid as the mobile phase with gradient elution, delivered at a flow-rate of 0.4 mL/min. Mass spectrometric analysis was performed using a XEVO TQD mass spectrometer coupled with an electro-spray ionization (ESI) source in the positive ion mode. The MRM transitions of m/z 610.91→302.98 and m/z 271.2→155.1 were used to quantify for rutin and tolbutamide, respectively. This assay method has been fully validated in terms of specificity, linearity, recovery and matrix effect, accuracy, precision and stability. Calibration curves were linear in the concentration ranges of 25-2000 ng/mL for rutin. Only 3 min was needed for an analytical run. This developed method was successfully used for determination of rutin in rat plasma for pharmacokinetic study.

  12. Identification of cephapirin metabolites and degradants in bovine milk by electrospray ionization--ion trap tandem mass spectrometry.

    Science.gov (United States)

    Heller, D N; Kaplan, D A; Rummel, N G; von Bredow, J

    2000-12-01

    Liquid chromatography-ion trap tandem mass spectrometry (LC-MS/MS) with electrospray ionization was used to identify cephapirin metabolites and degradants in milk from cows dosed with cephapirin. The milk was extracted according to a previously published procedure. Structures for various components were tentatively identified by their molecular weight, product ion mass spectra, and/or correspondence to standard mass spectra. These components may have occurred as metabolites or as degradants that occurred on storage or during extraction. Compounds identified in the milk included cephapirin, desacetylcephapirin, cephapirin lactone, hydrolyzed cephapirin, and a reduced cephapirin lactone that has not previously been reported. Methylcephapirin was also identified, possibly as a trace contaminant in the formulation. Analysis of incurred milk extracts showed that cephapirin and desacetylcephapirin are the major residues in milk. Desacetylcephapirin residues persisted about as long as the parent drug. The detection limit for both residues by LC-MS/MS was approximately 1 ng/mL in milk. These results have implications for microbiological methods or rapid test kits, if such methods or kits respond to cephapirin metabolites and degradants present in the milk. PMID:11141270

  13. Ruggedness testing and validation of a practical analytical method for > 100 veterinary drug residues in bovine muscle by ultrahigh performance liquid chromatography – tandem mass spectrometry

    Science.gov (United States)

    In this study, optimization, extension, and validation of a streamlined, qualitative and quantitative multiclass, multiresidue method was conducted to monitor great than100 veterinary drug residues in meat using ultrahigh-performance liquid chromatography – tandem mass spectrometry (UHPLC-MS/MS). I...

  14. Simultaneous quantification of purine and pyrimidine bases, nucleosides and their degradation products in bovine blood plasma by high performance liquid chromatography tandem mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Charlotte Stentoft; Vestergaard, Mogens; Løvendahl, Peter;

    2014-01-01

    ), and their degradation products (uric acid, allantoin, β-alanine, β-ureidopropionic acid, β-aminoisobutyric acid) in blood plasma of dairy cows. The high performance liquid chromatography-based technique coupled to electrospray ionization tandem mass spectrometry (LC–MS/MS) was combined with individual matrix...

  15. Ultra-high-performance liquid chromatography-tandem mass spectrometry measurement of climbazole deposition from hair care products onto artificial skin and human scalp

    NARCIS (Netherlands)

    G. Chen; M. Hoptroff; X. Fei; Y. Su; H.-G. Janssen

    2013-01-01

    A sensitive and specific ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for the measurement of climbazole deposition from hair care products onto artificial skin and human scalp. Deuterated climbazole was used as the internal st

  16. Diagnosis of glutaric aciduria type 1 by measuring 3-hydroxyglutaric acid in dried urine spots by liquid chromatography tandem mass spectrometry

    DEFF Research Database (Denmark)

    Al-Dirbashi, Osama Y; Kölker, Stefan; Ng, Dione;

    2011-01-01

    on stable isotope dilution gas chromatography mass spectrometry (GC-MS) and require extensive sample preparation. Here we describe a simple liquid chromatography tandem MS (LC-MS/MS) method to quantify this important metabolite in dried urine spots (DUS). This method is based on derivatization with 4-[2-(N...... enzymatic and molecular analyses to establish or refute the diagnosis of GA1....

  17. A validated liquid chromatography-tandem mass spectrometry method for the quantitative determination of 4 beta-hydroxycholesterol in human plasma

    NARCIS (Netherlands)

    van de Merbel, Nico C.; Bronsema, Kees J.; van Hout, Mischa W. J.; Nilsson, Ralf; Sillen, Henrik

    2011-01-01

    A novel liquid chromatography-tandem mass spectrometry method is described for the quantitative determination of the endogenous CYP 3A4/5 marker 4 beta-hydroxycholesterol in human K(2)-EDTA plasma. It is based on alkaline hydrolysis to convert esterified to free 4 beta-hydroxycholesterol, followed b

  18. Observation of T-2 and HT-2 glucosides from Fusarium sporotrichioides by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS)

    Science.gov (United States)

    Cultures of Fusarium sporotrichioides were extracted and subjected to evaluation by high performance liquid chromatography – tandem mass spectrometry (LC-MS/MS). Along with the expected T-2 and HT-2 toxins, compounds 162 m/z higher than the toxins were observed. Fragmentation behavior of the larger ...

  19. Comprehensive analysis of B-Lactam antibiotics including penicillins, cephalosporins and carbapenems in poultry muscle using liquid chromatography coupled to tandem mass spectrometry

    NARCIS (Netherlands)

    Berendsen, B.J.A.; Gerritsen, H.W.; Wegh, R.S.; Lameris, S.L.; Sebille, van R.; Stolker, A.A.M.; Nielen, M.W.F.

    2013-01-01

    A comprehensive method for the quantitative residue analysis of trace levels of 22 ß-lactam antibiotics, including penicillins, cephalosporins, and carbapenems, in poultry muscle by liquid chromatography in combination with tandem mass spectrometric detection is reported. The samples analyzed for ß-

  20. A new liquid chromatography - tandem mass spectrometry method using atmospheric pressure photo ionization for the simultaneous determination of azaarenes and azaarones in Dutch river sediments

    NARCIS (Netherlands)

    J. Brulik; Z. Simek; P. de Voogt

    2013-01-01

    A new method for the analysis of azaarenes and their degradation products (azaarones) was developed, optimized and validated using liquid chromatography coupled with atmospheric pressure photo ionization tandem mass spectrometric detection (LC-APPI/MS/MS). Seventeen compounds including 4 PAHs (napht

  1. Routine approach to qualitatively screen for 300 pesticides and quantify those frequently detected in fruits and vegetables using liquid chromatography tandem mass spectrometry

    Science.gov (United States)

    This paper describes an efficient and effective analytical scheme to first screen for 300 pesticides in fruit and vegetables samples using liquid chromatography tandem mass spectrometry (LC-MS/MS) with a commercial enhanced product ion method. Then, the presumed positive extracts were analyzed using...

  2. Evaluation of low-pressure gas chromatography-tandem mass spectrometry method for analysis of greater than 140 pesticides in fish

    Science.gov (United States)

    A multi-residue method for analysis of 143 pesticide residues in fish was developed and evaluated using fast, low pressure gas chromatography triple quadrupole tandem mass spectrometry (LP-GC/MS-MS). The method was based on a QuEChERS (quick, easy, cheap, effective, rugged, safe) extraction with ace...

  3. A high-performance liquid chromatography-tandem mass spectrometry method for the determination of artemether and dihydroartemisinin in human plasma

    NARCIS (Netherlands)

    Hilhorst, M J; Hendriks, G; de Vries, R; Hillewaert, V; Verhaege, T; van de Merbel, N C

    2014-01-01

    A liquid chromatography-tandem mass spectrometry method is described for the quantitative determination of artemether (ART) and its metabolite dihydroartimisinin (DHA) in human plasma samples. Quantitation of ART and DHA in plasma is challenging due to the presence of malaria related hemolytic produ

  4. Liquid chromatography with tandem mass spectrometry quantification of urinary proanthocyanin A2 dimer and its potential use as a biomarker of cranberry intake

    Science.gov (United States)

    The lack of a biomarker for the consumption of cranberries has confounded the interpretation of several studies investigating the effect of cranberry products, especially juices, on health outcomes. The objectives of this pilot study were to develop a liquid chromatography tandem mass spectrometric ...

  5. METHOD 544. DETERMINATION OF MICROCYSTINS AND NODULARIN IN DRINKING WATER BY SOLID PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/TANDEM MASS SPECTROMETRY (LC/MS/MS)

    Science.gov (United States)

    Method 544 is an accurate and precise analytical method to determine six microcystins (including MC-LR) and nodularin in drinking water using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE-LC/MS/MS). The advantage of this SPE-LC/MS/MS is its sensi...

  6. Assessment of Feasibility of Maillard Reaction between Baclofen and Lactose by Liquid Chromatography and Tandem Mass Spectrometry, Application to Pre Formulation Studies

    OpenAIRE

    Monajjemzadeh, Farnaz; Hassanzadeh, Davoud; Valizadeh, Hadi; Siahi-Shadbad, Mohammad R.; Mojarrad, Javid Shahbazi; Robertson, Thomas; Roberts, Michael S

    2009-01-01

    The aim of this study was to determine any possible, baclofen–lactose Maillard reaction products. Granules and tablets of baclofen and lactose were prepared and maintained in heat ovens for a certain time period. The effects of lactose type, addition of magnesium stearate, and water were monitored. Heated lactose and baclofen were analyzed using reverse-phase HPLC. Liquid chromatography tandem mass spectroscopy revealed nominal mass values consistent with baclofen–lactose, early-stage Maillar...

  7. Applying 'Sequential Windowed Acquisition of All Theoretical Fragment Ion Mass Spectra' (SWATH) for systematic toxicological analysis with liquid chromatography-high-resolution tandem mass spectrometry.

    Science.gov (United States)

    Arnhard, Kathrin; Gottschall, Anna; Pitterl, Florian; Oberacher, Herbert

    2015-01-01

    Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has become an indispensable analytical technique in clinical and forensic toxicology for detection and identification of potentially toxic or harmful compounds. Particularly, non-target LC-MS/MS assays enable extensive and universal screening requested in systematic toxicological analysis. An integral part of the identification process is the generation of information-rich product ion spectra which can be searched against libraries of reference mass spectra. Usually, 'data-dependent acquisition' (DDA) strategies are applied for automated data acquisition. In this study, the 'data-independent acquisition' (DIA) method 'Sequential Windowed Acquisition of All Theoretical Fragment Ion Mass Spectra' (SWATH) was combined with LC-MS/MS on a quadrupole-quadrupole-time-of-flight (QqTOF) instrument for acquiring informative high-resolution tandem mass spectra. SWATH performs data-independent fragmentation of all precursor ions entering the mass spectrometer in 21m/z isolation windows. The whole m/z range of interest is covered by continuous stepping of the isolation window. This allows numerous repeat analyses of each window during the elution of a single chromatographic peak and results in a complete fragment ion map of the sample. Compounds and samples typically encountered in forensic casework were used to assess performance characteristics of LC-MS/MS with SWATH. Our experiments clearly revealed that SWATH is a sensitive and specific identification technique. SWATH is capable of identifying more compounds at lower concentration levels than DDA does. The dynamic range of SWATH was estimated to be three orders of magnitude. Furthermore, the >600,000 SWATH spectra matched led to only 408 incorrect calls (false positive rate = 0.06 %). Deconvolution of generated ion maps was found to be essential for unravelling the full identification power of LC-MS/MS with SWATH. With the available software, however, only semi

  8. Fast gas chromatography and negative-ion chemical ionization tandem mass spectrometry for forensic analysis of cannabinoids in whole blood.

    Science.gov (United States)

    Thomas, Aurélien; Widmer, Christèle; Hopfgartner, Gérard; Staub, Christian

    2007-11-01

    The present work describes a fast gas chromatography/negative-ion chemical ionization tandem mass spectrometric assay (Fast GC/NICI-MS/MS) for analysis of tetrahydrocannabinol (THC), 11-hydroxy-tetrahydrocannabinol (THC-OH) and 11-nor-9-carboxy-tetrahydrocannabinol (THC-COOH) in whole blood. The cannabinoids were extracted from 500 microL of whole blood by a simple liquid-liquid extraction (LLE) and then derivatized by using trifluoroacetic anhydride (TFAA) and hexafluoro-2-propanol (HFIP) as fluorinated agents. Mass spectrometric detection of the analytes was performed in the selected reaction-monitoring mode on a triple quadrupole instrument after negative-ion chemical ionization. The assay was found to be linear in the concentration range of 0.5-20 ng/mL for THC and THC-OH, and of 2.5-100 ng/mL for THC-COOH. Repeatability and intermediate precision were found less than 12% for all concentrations tested. Under standard chromatographic conditions, the run cycle time would have been 15 min. By using fast conditions of separation, the assay analysis time has been reduced to 5 min, without compromising the chromatographic resolution. Finally, a simple approach for estimating the uncertainty measurement is presented. PMID:17913432

  9. Determination of cyclovirobuxine D in human plasma by liquid chromatography tandem mass spectrometry and application in a pharmacokinetic study

    Directory of Open Access Journals (Sweden)

    Ling-li Mu

    2011-10-01

    Full Text Available A sensitive and reliable method based on liquid chromatography tandem mass spectrometry (LC–MS/MS for the quantitation of cyclovirobuxine D in human plasma has been developed and validated. Sample preparation by solid phase extraction was followed by separation on a CN column with a mobile phase of methanol–water (95:5, v/v containing 0.2% formic acid. Mass spectrometric detection in the positive ion mode was carried out by selected reaction monitoring (SRM of the transitions at m/z 403.0→372.0 for cyclovirobuxine D and m/z 325.0→234.0 for citalopram (internal standard. The method was linear in the range 10–200 ng/L with LLOQ of 10 ng/L, recovery >85%, and no significant matrix effects. Intra- and inter-day precisions were all <9% with accuracies of 94.0–104.8%. The method was successfully applied to a pharmacokinetic study involving a single oral administration of a 2 mg cyclovirobuxine D tablet to twenty-two healthy Chinese volunteers.

  10. Direct determination of glyphosate, glufosinate, and AMPA in soybean and corn by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Chamkasem, Narong; Harmon, Tiffany

    2016-07-01

    Glyphosate, glufosinate, and aminomethylphosphonic acid (AMPA) are amphoteric, low mass, high water soluble, and do not have chromophore. They are very difficult to be retained on a reversed phase HPLC and detected by UV or fluorescence detectors. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed to determine these analytes in soybean and corn using a reversed phase with weak anion-exchange and cation-exchange mixed-mode Acclaim™ Trinity™ Q1 column. The sample was shaken with water containing ethylenediaminetetraacetic acid disodium salt (Na2EDTA) and acetic acid for 10 min to precipitate protein and extract the analytes into the solution. The supernatant was passed thru an Oasis HLB SPE to retain suspended particulates and non-polar interferences. The sample was directly injected and analyzed in 6 min by LC-MS/MS with no sample concentration or derivatization steps. Three isotopically labeled internal standards corresponding to each analyte were used to counter matrix suppression effect. Linearity of the detector response with a minimum coefficient of determination (R (2)) of more than 0.995 was demonstrated in the range of 10 to 1000 ng/mL for each analyte. Accuracy (recovery %) and precision (relative standard deviation or RSD %) were evaluated at the fortification levels of 0.1, 0.5, and 2 μg/g in seven replicates in both soybean and corn samples. PMID:27150204

  11. Simultaneous determination of six phenolic constituents of danshen in human serum using liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Li, Xiaochuan; Yu, Chen; Cai, Yongbao; Liu, Gangyi; Jia, Jingying; Wang, Yiping

    2005-06-01

    The six phenolic constituents are water-soluble components extracted from the Chinese medical herb danshen, the dried roots of Salvia miltiorrhiza Bunge (Labiatae). An liquid chromatography/tandem mass spectrometry (LC/MS/MS)-based method has been developed for the simultaneous quantification of six phenolic constituents of danshen (magnesium lithospermate B (MLB), rosmarinic acid (RA) and lithospermic acid (LA), caffeic acid (CAA), protocatechuic aldehyde (3,4-dihydroxybenzaldehyde, Pal), 3,4-dihydroxyphenyllactic acid (danshensu)) in human serum with chloramphenicol as internal standard. The serum samples were treated by special liquid-liquid extraction, and the analytes were determined using electrospray negative ionization mass spectrometry in the multiple reaction monitoring (MRM) mode, with sufficient sensitivity to allow analysis of human serum samples generated following administration of a clinically relevant dose. Good linearity over the range 8-2048 ng/mL for six phenolic constituents was observed. The intra- and inter-day precisions (CV) of analysis were <13%, and the accuracy ranged from 88 to 116%. This quantitation method was successfully applied to a pharmacokinetic study of i.v. drip infusion of Danshen injection fluid in human. PMID:15866491

  12. Determination of Platycodin D and Platycodin D3 in Rat Plasma Using Liquid Chromatography-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Tae-Hyun Kim

    2014-01-01

    Full Text Available Platycodon grandiflorum has long been used as a traditional oriental medicine for respiratory disorder. Platycodin D (PD is known as the main component isolated from the root of PG. A simple and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS method has been developed and validated for the quantitation of PD in rat plasma. Quantitation was performed on a triple quadrupole mass spectrometer employing electrospray ionization and multiple reaction monitoring in positive ion mode. The total chromatographic run time was 4.0 min, and the calibration curves of PD were linear over the concentration range of 50–10,000 ng/mL in rat plasma. The coefficient of variation and relative error at five QC levels were 1.0 to 8.8% and 0.7 to 8.7%, respectively. After a single oral administration of 500 mg/kg and a single intravenous administration of 25 mg/kg of 3% PD extract (a PG extract including 3% of PD, platycodin D and platycodin D3 were detected and pharmacokinetic parameters were estimated. The oral bioavailability of platycodin D and platycodin D3 was 0.29% and 1.35% in rats at 500 mg/kg of 3% PD extract of PG, respectively. The present method can be applied to pharmacokinetic analysis of platycodins and platycosides of the PG.

  13. Qualitative and quantitative analysis of glucosinolates and nucleosides in Radix Isatidis by HPLC and liquid chromatography tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Xiuming Wang

    2013-09-01

    Full Text Available Multi-component fingerprinting and quantitation of the glucosinolates and nucleosides in samples of Radix Isatidis have been carried out using high-performance liquid chromatography with diode-array detection and electrospray ionization tandem mass spectrometry (HPLC–DAD–ESI/MS. Five nucleosides together with one glucosinolate were identified by comparing retention times, ultraviolet spectra, mass spectra and/or empirical molecular formulae of reference compounds. Quantitation of these six compounds was carried out simultaneously by HPLC on a Phenomenex Luna C18 column using gradient elution with methanol and water and detection at 254 nm. All calibration curves were linear (r>0.9994 within test ranges. Limits of detection and quantitation were 0.33 ng and 2.50 ng on column, respectively. Intra- and inter-day precision (as relative standard deviation for all analytes was <2.19% with recoveries in the range 99.6%–101.8% at three concentration levels. The validated method was successfully applied to fingerprinting and assay of 25 batches of Radix Isatidis sourced from different geographical regions of China. The method is simple and reliable and has potential value in the quality control of Radix Isatidis.

  14. Total microcystins analysis in water using laser diode thermal desorption-atmospheric pressure chemical ionization-tandem mass spectrometry.

    Science.gov (United States)

    Roy-Lachapelle, Audrey; Fayad, Paul B; Sinotte, Marc; Deblois, Christian; Sauvé, Sébastien

    2014-04-11

    A new approach for the analysis of the cyanobacterial microcystins (MCs) in environmental water matrices has been developed. It offers a cost efficient alternative method for the fast quantification of total MCs using mass spectrometry. This approach permits the quantification of total MCs concentrations without requiring any derivatization or the use of a suite of MCs standards. The oxidation product 2-methyl-3-methoxy-4-phenylbutyric acid (MMPB) was formed through a Lemieux oxidation and represented the total concentration of free and bound MCs in water samples. MMPB was analyzed using laser diode thermal desorption-atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). LDTD is a robust and reliable sample introduction method with ultra-fast analysis time (0.999). Limits of detection and quantification were 0.2 and 0.9 μg L(-1), respectively. These values are comparable with the WHO (World Health Organization) guideline of 1 μg L(-1) for total microcystin-LR congener in drinking water. Accuracy and interday/intraday variation coefficients were below 15%. Matrix effect was determined with a recovery of 91%, showing no significant signal suppression. This work demonstrates the use of the LDTD-APCI-MS/MS interface for the screening, detection and quantification of total MCs in complex environmental matrices.

  15. Paired-ion electrospray ionization--triple quadrupole tandem mass spectrometry for quantification of anionic surfactants in waters.

    Science.gov (United States)

    Santos, Inês C; Guo, Hongyue; Mesquita, Raquel B R; Rangel, António O S S; Armstrong, Daniel W; Schug, Kevin A

    2015-10-01

    A new paired ion electrospray ionization tandem mass spectrometry method for determination of anionic surfactants in water samples was developed. In this method, dicationic ion-pairing reagents were complexed with monoanionic analytes to facilitate analyte detection in positive mode electrospray ionization - mass spectrometry. Single ion monitoring and selected reaction monitoring on a triple quadrupole instrument were performed and compared. Four dicationic reagents were tested for the determination of perfluorooctanoic acid (PFOA), perfluorooctane sulfonate (PFOS), sodium dodecyl sulfate (SDS), dodecylbenzene sulfonic acid (DBS), and stearic acid (SA), among other common anions. The obtained limits of detection were compared with those from previous literature. Solid phase extraction using a C18 cartridge was performed in order to eliminate matrix interferences. A literature review was compiled for the methods published between 2010 and 2015 for determination of anionic surfactants. The optimized method was more sensitive than previously developed methods with LOD values of 2.35, 35.4, 37.0, 1.68, and 0.675 pg for SDS, SA, DBS, PFOS, and PFOA, respectively. The developed method was effectively applied for the determination of anionic surfactants in different water samples such as bottled drinking water, cooking water, tap water, and wastewater.

  16. Simultaneous determination of ten underivatized biogenic amines in meat by liquid chromatography-tandem mass spectrometry (HPLC-MS/MS).

    Science.gov (United States)

    Sirocchi, Veronica; Caprioli, Giovanni; Ricciutelli, Massimo; Vittori, Sauro; Sagratini, Gianni

    2014-09-01

    Biogenic amines (BAs) are considered to be important indicators of freshness and quality in food. In this work, an analytical method for analyzing ten underivatized BAs in meat by performance liquid chromatography-tandem mass spectrometry has been developed. Comparison between ion trap and triple quadrupole as mass analyzers indicated that the latter provides greater sensitivity and selectivity. The range of the correlation coefficients of the calibration curves of the analyzed compounds was 0.987-0.999, and the limits of detection and limits of quantification were in the range of 0.002-0.1 mg l(-1) and 0.008-0.5 mg l(-1), respectively. Once validated, the method was used to analyze the concentrations of BAs in 16 commercial meat samples, for evaluating the freshness of food through the study of BA indices, i.e. biogenic amine index (BAI) and the ratio spermidine/spermine (SPD/SPE). The results indicated that all the samples were fresh, with a BAI lower than 1.49 mg kg(-1) and a SPD/SPE ratio lower than 0.41 in each case. This methodology for testing the freshness of meat has potential for quality control applications along the entire production chain of meat products. PMID:25230178

  17. Simultaneous determination of decitabine and vorinostat (Suberoylanalide hydroxamic acid, SAHA) by liquid chromatography tandem mass spectrometry for clinical studies.

    Science.gov (United States)

    Patel, Katan; Guichard, Sylvie M; Jodrell, Duncan I

    2008-02-15

    A reverse-phase high-performance liquid chromatography method with electrospray ionization and detection by tandem mass spectrometry is described for the simultaneous quantitative determination of decitabine (5-aza-2'-deoxycytidine) and vorinostat (Suberoylanalide hydroxamic acid, SAHA) in human plasma. The method involves a simple acetonitrile precipitation step and centrifugation followed by injection of the supernatant onto a C18 150mmx2.1mm I.D., 3microm HPLC column at 36 degrees C. Separation of decitabine, SAHA and their respective internal standards was achieved with a gradient elution and detection was via the mass spectrometer operated in selected reaction monitoring mode. The method was within the defined validation parameters for linearity, repeatability, reproducibility and stability. The limit of detection was determined as 1.0 and 0.125ngml(-1) and lower limits of quantitation were 10 and 1ngml(-1) for decitabine and SAHA, respectively. Effects of sample preparation on stability were also evaluated in human plasma. For clinical sample handling tetrahydrouridine, an inhibitor of cytidine deaminase was found to help prevent decitabine degradation. The method is currently being used in clinical pharmacokinetic studies for the evaluation of decitabine and SAHA combination therapies.

  18. Paired-ion electrospray ionization--triple quadrupole tandem mass spectrometry for quantification of anionic surfactants in waters.

    Science.gov (United States)

    Santos, Inês C; Guo, Hongyue; Mesquita, Raquel B R; Rangel, António O S S; Armstrong, Daniel W; Schug, Kevin A

    2015-10-01

    A new paired ion electrospray ionization tandem mass spectrometry method for determination of anionic surfactants in water samples was developed. In this method, dicationic ion-pairing reagents were complexed with monoanionic analytes to facilitate analyte detection in positive mode electrospray ionization - mass spectrometry. Single ion monitoring and selected reaction monitoring on a triple quadrupole instrument were performed and compared. Four dicationic reagents were tested for the determination of perfluorooctanoic acid (PFOA), perfluorooctane sulfonate (PFOS), sodium dodecyl sulfate (SDS), dodecylbenzene sulfonic acid (DBS), and stearic acid (SA), among other common anions. The obtained limits of detection were compared with those from previous literature. Solid phase extraction using a C18 cartridge was performed in order to eliminate matrix interferences. A literature review was compiled for the methods published between 2010 and 2015 for determination of anionic surfactants. The optimized method was more sensitive than previously developed methods with LOD values of 2.35, 35.4, 37.0, 1.68, and 0.675 pg for SDS, SA, DBS, PFOS, and PFOA, respectively. The developed method was effectively applied for the determination of anionic surfactants in different water samples such as bottled drinking water, cooking water, tap water, and wastewater. PMID:26078166

  19. Liquid Chromatography with Tandem Mass Spectrometry: A Sensitive Method for the Determination of Dehydrodiisoeugenol in Rat Cerebral Nuclei

    Directory of Open Access Journals (Sweden)

    You-Bo Zhang

    2016-03-01

    Full Text Available A new liquid chromatography–tandem mass spectrometry (LC-MS/MS method is developed for the quantification of dehydrodiisoeugenol (DDIE in rat cerebral nuclei after single intravenous administration. DDIE and daidzein (internal standard were separated on a Diamonsil™ ODS C18 column with methanol–water containing 0.1% formic acid (81:19, v/v as a mobile phase. Detection of DDIE was performed on a positive electrospray ionization source using a triple quadrupole mass spectrometer. DDIE and daidzein were monitored at m/z 327.2→188.0 and m/z 255.0→199.2, respectively, in multiple reaction monitoring mode. This method enabled quantification of DDIE in various brain areas, including, cortex, hippocampus, striatum, hypothalamus, cerebellum and brainstem, with high specificity, precision, accuracy, and recovery. The data herein demonstrate that our new LC-MS/MS method is highly sensitive and suitable for monitoring cerebral nuclei distribution of DDIE.

  20. Quantitation of protein S-glutathionylation by liquid chromatography-tandem mass spectrometry: correction for contaminating glutathione and glutathione disulfide.

    Science.gov (United States)

    Bukowski, Michael R; Bucklin, Christopher; Picklo, Matthew J

    2015-01-15

    Protein S-glutathionylation is a posttranslational modification that links oxidative stimuli to reversible changes in cellular function. Protein-glutathione mixed disulfide (PSSG) is commonly quantified by reduction of the disulfide and detection of the resultant glutathione species. This methodology is susceptible to contamination by free unreacted cellular glutathione (GSH) species, which are present in 1000-fold greater concentration. A liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based method was developed for quantification of glutathione and glutathione disulfide (GSSG), which was used for the determination of PSSG in biological samples. Analysis of rat liver samples demonstrated that GSH and GSSG coprecipitated with proteins similar to the range for PSSG in the sample. The use of [(13)C2,(5)N]GSH and [(13)C4,(5)N2]GSSG validated these results and demonstrated that the release of GSH from PSSG did not occur during sample preparation and analysis. These data demonstrate that GSH and GSSG contamination must be accounted for when determining PSSG content in cellular/tissue preparations. A protocol for rinsing samples to remove the adventitious glutathione species is demonstrated. The fragmentation patterns for glutathione were determined by high-resolution mass spectrometry, and candidate ions for detection of PSSG on protein and protein fragments were identified.