WorldWideScience

Sample records for chromatography mass spectrometry

  1. Pyrolysis - gas chromatography - mass spectrometry of lignins

    Energy Technology Data Exchange (ETDEWEB)

    Martin, F.; Saiz-Jimenez, C.; Gonzalez-Vila, F.J.

    1979-01-01

    Milled wood lignins from spruce, beech and bamboo were pyrolysed. The high-boiling products of pyrolysis were studied by GLC and mass spectrometry. The forty-three products identified provide information on the structural units of lignin.

  2. High-Performance Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Vestal, Marvin L.

    1984-01-01

    Reviews techniques for online coupling of high-performance liquid chromatography with mass spectrometry, emphasizing those suitable for application to nonvolatile samples. Also summarizes the present status, strengths, and weaknesses of various techniques and discusses potential applications of recently developed techniques for combined liquid…

  3. Advancing liquid chromatography- mass spectrometry based technologies for proteome research

    NARCIS (Netherlands)

    Boersema, P.J.

    2010-01-01

    In proteomics, high-tech nano-liquid chromatography (LC) and mass spectrometry (MS) instrumentation is used to routinely sequence proteins at a large scale. In this thesis, several technological developments are described to advance proteomics and their applicability is demonstrated in several diffe

  4. Characterisation of cholera toxin by liquid chromatography - Electrospray mass spectrometry

    NARCIS (Netherlands)

    Baar, B.L.M. van; Hulst, A.G.; Wils, E.R.J.

    1999-01-01

    Cholera toxin, one of the toxins that may be generated by various strains of the bacterium Vibrio cholerae, can be considered as a substance possibly used in biological warfare. The possibilities of characterising the toxin by liquid chromatography electrospray mass spectrometry (LC-ES-MS) were inve

  5. Analysis of essential oils by gas chromatography and mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Masada, Y.

    1976-01-01

    The book is in two parts: first part Essential Oil includes compositae; labiatae; verbenaceae; oleaceae; umbelliferae; myrtaceae; euphorbiaceae; rutaceae; geraniaceae; rosaceae; lauraceae; myristicaceae; anonaceae; santalaceae; moraceae; piperaceae; zingiberaceae; araceae; gramineae; and cupressaceae written in English and Japanese. Part two includes essential oil; gas chromatography, and mass spectrometry written in Japanese. (DP)

  6. Specialized Gas Chromatography--Mass Spectrometry Systems for Clinical Chemistry.

    Science.gov (United States)

    Gochman, Nathan; And Others

    1979-01-01

    A discussion of the basic design and characteristics of gas chromatography-mass spectrometry systems used in clinical chemistry. A comparison of three specific systems: the Vitek Olfax IIA, Hewlett-Packard HP5992, and Du Pont DP-102 are included. (BB)

  7. MICELLAR ELECTROKINETIC CHROMATOGRAPHY-MASS SPECTROMETRY (R823292)

    Science.gov (United States)

    The combination of micellar electrokinetic chromatography (MEKC) with mass spectrometry (MS) is very attractive for the direct identification of analyte molecules, for the possibility of selectivity enhancement, and for the structure confirmation and analysis in a MS-MS mode. The...

  8. Analysis of protein composition using multidimensional chromatography and mass spectrometry.

    Science.gov (United States)

    Link, Andrew J; Washburn, Michael P

    2014-11-03

    Multidimensional liquid chromatography of peptides produced by protease digestion of complex protein mixtures followed by tandem mass spectrometry can be coupled with automated database searching to identify large numbers of proteins in complex samples. These methods avoid the limitations of gel electrophoresis and in-gel digestions by directly identifying protein mixtures in solution. One method used extensively is named Multidimensional Protein Identification Technology (MudPIT), where reversed-phase chromatography and strong cation-exchange chromatography are coupled directly in a microcapillary column. This column is then placed in line between an HPLC and a mass spectrometer for complex mixture analysis. MudPIT remains a powerful approach for analyzing complex mixtures like whole proteomes and protein complexes. MudPIT is used for quantitative proteomic analysis of complex mixtures to generate novel biological insights.

  9. Protein identification using nano liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Negroni, Luc

    2007-01-01

    Tandem mass spectrometry is an efficient technique for the identification of peptides on the basis of their fragmentation pattern (MS/MS scan). It can generate individual spectra for each peptide, thereby creating a powerful tool for protein identification on the basis of peptide characterization. This important advance in automatic data acquisition has allowed an efficient association between liquid chromatography and tandem mass spectrometry, and the use of nanocolumns and nanoelectrospray ionization has dramatically increased the efficiency of this method. Now large sets of peptides can be identified at a femtomole level. At the end of the process, batch processing of the MS/MS spectra produces peptide lists that identify purified proteins or protein mixtures with high confidence.

  10. Capillary supercritical fluid chromatography-mass spectrometry (SFC-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Kalinoski, H.T.; Udseth, H.R.; Chess, E.K.; Smith, R.D.

    1986-10-01

    The physical and chemical characteristics of supercritical fluids have prompted the development of supercritical fluid chromatography (SFC) for the analysis of labile and less volatile compounds. High resolution chromatographic separations with efficiencies approaching those of gas chromatography and high speed analyses are possible in capillary SFC using pressure programming methods and narrow bore columns. Further refinement of the SFC-mass spectrometry interface (SFC-MS) provides the basis for extension to more polar fluid systems with greater solvating power and the selectivity and sensitivity of mass spectrometric detection. The use of polar modified fluids has been facilitated by advances in understanding of supercritical fluid phase behavior. Fluid mixtures have been prepared for analysis of more polar, higher molecular weight analytes, that allow mild chromatographic temperatures and allow full exploitation of selectivity offered through control of fluid pressure (i.e., density). Continuing development of the SFC-MS interface has led to designs which can be near routinely applied with fluids such as CO/sub 2/, and providing enhanced transport of truly nonvolatile compounds to the mass spectrometer ionization regions. These advances also include an SFC interface to a high resolution, dual electric magnetic sector instrument, allowing supercritical fluid solvents to be explited for on-line extraction-mass spectrometry for characterization of complex, often otherwise intractable, materials. 26 refs., 5 figs., 1 tab.

  11. Liquid chromatography mass spectrometry for analysis of microbial metabolites

    DEFF Research Database (Denmark)

    Klitgaard, Andreas

    are still to be discovered. The main analytical technique used to investigate production of products from these diverse organisms is liquid-chromatography coupled to mass spectrometry (LC-MS). With the development of new and improved analytical instrumentation for chemical analysis, the time needed...... to human health. Because of this, methods for detection and analysis of these compounds are vital. Estimates suggest that there are around 1.5 million different fungal species on Earth, dwarfing the number of plants estimated to 300,000, meaning that there potentially are many more interesting compounds...... to perform a single analytical run has decreased, while the amount of information obtained from each of these analytical runs has increased drastically. Consequently, the limiting step in chemical analysis of a microorganism is no longer the analytical run itself, but rather analysis of the resulting data...

  12. Estimation of brassylic acid by gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mohammed J. Nasrullah, Erica N. Pfarr, Pooja Thapliyal, Nicholas S. Dusek, Kristofer L. Schiele, Christy Gallagher-Lein, and James A. Bahr

    2010-10-29

    The main focus of this work is to estimate Brassylic Acid (BA) using gas chromatography-mass spectrometry (GC-MS). BA is a product obtained from the oxidative cleavage of Erucic Acid (EA). BA has various applications for making nylons and high performance polymers. BA is a 13 carbon compound with two carboxylic acid functional groups at the terminal end. BA has a long hydrocarbon chain that makes the molecule less sensitive to some of the characterization techniques. Although BA can be characterized by NMR, both the starting material (EA) and products BA and nonanoic acid (NA) have peaks at similar {delta}, ppm values. Hence it becomes difficult for the quick estimation of BA during its synthesis.

  13. Identification of Unknown Contaminants in Water Samples from ISS Employing Liquid Chromatography/Mass Spectrometry/Mass Spectrometry

    Science.gov (United States)

    Rutz, Jeffrey A.; Schultz, John R.

    2008-01-01

    Mass Spectrometry/Mass Spectrometry (MS/MS) is a powerful technique for identifying unknown organic compounds. For non-volatile or thermally unstable unknowns dissolved in liquids, liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) is often the variety of MS/MS used for the identification. One type of LC/MS/MS that is rapidly becoming popular is time-of-flight (TOF) mass spectrometry. This technique is now in use at the Johnson Space Center for identification of unknown nonvolatile organics in water samples from the space program. An example of the successful identification of one unknown is reviewed in detail in this paper. The advantages of time-of-flight instrumentation are demonstrated through this example as well as the strategy employed in using time-of-flight data to identify unknowns.

  14. The Use of Gas Chromatography and Mass Spectrometry to Introduce General Chemistry Students to Percent Mass and Atomic Mass Calculations

    Science.gov (United States)

    Pfennig, Brian W.; Schaefer, Amy K.

    2011-01-01

    A general chemistry laboratory experiment is described that introduces students to instrumental analysis using gas chromatography-mass spectrometry (GC-MS), while simultaneously reinforcing the concepts of mass percent and the calculation of atomic mass. Working in small groups, students use the GC to separate and quantify the percent composition…

  15. VACUUM DISTILLATION COUPLED WITH GAS CHROMATOGRAPHY/MASS SPECTROMETRY FOR THE ANALYSIS OF ENVIRONMENTAL SAMPLES

    Science.gov (United States)

    A procedure is presented that uses a vacuum distillation/gas chromatography/mass spectrometry system for analysis of problematic matrices of volatile organic compounds. The procedure compensates for matrix effects and provides both analytical results and confidence intervals from...

  16. STRUCTURAL CHARACTERIZATION OF THE DECOMPOSITION PRODUCTS OF SALBUTAMOL BY LIQUID-CHROMATOGRAPHY IONSPRAY MASS-SPECTROMETRY

    NARCIS (Netherlands)

    MALKKILAINE, L; BRUINS, AP

    1994-01-01

    Liquid chromatography-ionspray mass spectrometry was used to elucidate the structures of the decomposition products of salbutamol. The best sensitivity in mass spectrometry was achieved by using a mixture of acetonitrile and ammonium formate (10 mM, pH 3.3) as the mobile phase in liquid chromatograp

  17. DETERMINATION OF ACRYLAMIDE IN FOOD BY GAS AND LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY

    OpenAIRE

    Michaela Vieriková; Miriam Vlčáková

    2010-01-01

     Acrylamide in food was determined by gas chromatography - mass spectrometry (GC-MS) after bromination of acrylamide and underivatized acrylamide was quantified by ultra performance liquid chromatography -mass spectrometry (UPLC-MS). Two different sample preparation methods were used and optimised. The GC-MS method was used for various food matrices like breads, potato crisps, potato crackers, french fries. The UPLC-MS method was used for analysis of coffee. The limit of detect...

  18. Uncovering biologically significant lipid isomers with liquid chromatography, ion mobility spectrometry and mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kyle, Jennifer E.; Zhang, Xing; Weitz, Karl K.; Monroe, Matthew E.; Ibrahim, Yehia M.; Moore, Ronald J.; Cha, Jeeyeon; Sun, Xiaofei; Lovelace, Erica S.; Wagoner, Jessica; Polyak, Steve; Metz, Thomas O.; Dey, Sudhansu K.; Smith, Richard D.; Burnum-Johnson, Kristin E.; Baker, Erin Shammel

    2016-01-01

    Understanding how biological molecules are generated, metabolized and eliminated in living systems is important for interpreting processes such as immune response and disease pathology. While genomic and proteomic studies have provided vast amounts of information over the last several decades, interest in lipidomics has also grown due to improved analytical technologies revealing altered lipid metabolism in type 2 diabetes, cancer, and lipid storage disease. Liquid chromatography and mass spectrometry (LC-MS) measurements are currently the dominant approach for characterizing the lipidome by providing detailed information on the spatial and temporal composition of lipids. However, interpreting lipids’ biological roles is challenging due to the existence of numerous structural and stereoisomers (i.e. distinct acyl chain and double-bond positions), which are unresolvable using present LC-MS approaches. Here we show that combining structurally-based ion mobility spectrometry (IMS) with LC-MS measurements distinguishes lipid isomers and allows insight into biological and disease processes.

  19. Identification of Cyclopentenyl Fatty Acids by Gas Liquid Chromatography and Mass Spectrometry

    DEFF Research Database (Denmark)

    Shukla, V. K. S.; Abdel-Moety, E. M.; Larsen, Elfinn;

    1979-01-01

    The straight chain fatty acids and the cyclopentenyl fatty acids present in the lipids of Hydnocarpus wightiana seeds were separated as their pyrrolidides by means of gas chromatography. A gas chromatography-mass spectrometry system confirmed the complete separation and permitted the identification...

  20. Simultaneous Proteomic Discovery and Targeted Monitoring using Liquid Chromatography, Ion Mobility Spectrometry, and Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Burnum-Johnson, Kristin E.; Nie, Song; Casey, Cameron P.; Monroe, Matthew E.; Orton, Daniel J.; Ibrahim, Yehia M.; Gritsenko, Marina A.; Clauss, Therese R. W.; Shukla, Anil K.; Moore, Ronald J.; Purvine, Samuel O.; Shi, Tujin; Qian, Weijun; Liu, Tao; Baker, Erin S.; Smith, Richard D.

    2016-09-25

    Current proteomics approaches are comprised of both broad discovery measurements as well as more quantitative targeted measurements. These two different measurement types are used to initially identify potentially important proteins (e.g., candidate biomarkers) and then enable improved quantification for a limited number of selected proteins. However, both approaches suffer from limitations, particularly the lower sensitivity, accuracy, and quantitation precision for discovery approaches compared to targeted approaches, and the limited proteome coverage provided by targeted approaches. Herein, we describe a new proteomics approach that allows both discovery and targeted monitoring (DTM) in a single analysis using liquid chromatography, ion mobility spectrometry and mass spectrometry (LC-IMS-MS). In DTM, heavy labeled peptides for target ions are spiked into tryptic digests and both the labeled and unlabeled peptides are broadly detected using LC-IMS-MS instrumentation, allowing the benefits of discovery and targeted approaches. To understand the possible improvement of the DTM approach, it was compared to LC-MS broad measurements using an accurate mass and time tag database and selected reaction monitoring (SRM) targeted measurements. The DTM results yielded greater peptide/protein coverage and a significant improvement in the detection of lower abundance species compared to LC-MS discovery measurements. DTM was also observed to have similar detection limits as SRM for the targeted measurements indicating its potential for combining the discovery and targeted approaches.

  1. Liquid chromatography-thermospray mass spectrometry of DNA adducts formed with mitomycin C, porfiromycin and thiotepa.

    Science.gov (United States)

    Musser, S M; Pan, S S; Callery, P S

    1989-07-14

    High-performance liquid chromatography (HPLC) and thermospray mass spectrometry were combined for the analysis of DNA adducts formed from the interaction of the anticancer drugs mitomycin C, porfiromycin and thiotepa with calf thymus DNA. The adducts formed from reaction of mitomycin C and porfiromycin with DNA were separated from unmodified nucleosides by HPLC on a C18 column and identified by thermospray mass spectrometry. Thiotepa DNA adducts readily depurinated from DNA and were chromatographed and identified by thermospray liquid chromatography-mass spectrometry as the modified bases without the ribose moiety attached. The utility of thermospray mass spectrometry for the identification of microgram quantities of nucleoside adducts and depurinated base adducts of these anticancer drugs was demonstrated.

  2. The analysis of aqueous mixtures using liquid chromatography-electrospray mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Steven [Iowa State Univ., Ames, IA (United States)

    1999-02-12

    The focus of this dissertation is the use of chromatographic methods coupled with electrospray mass spectrometry (ES-MS) for the determination of both organic and inorganic compounds in aqueous solutions. The combination of liquid chromatography (LC) methods and ES-MS offers one of the foremost methods for determining compounds in complex aqueous solutions. In this work, LC-ES-MS methods are devised using ion exclusion chromatography, reversed phase chromatography, and ion exchange chromatography, as well as capillary electrophoresis (CE). For an aqueous sample, these LC-ES-MS and CE-ES-MS techniques require no sample preparation or analyte derivatization, which makes it possible to observe a wide variety of analytes as they exist in solution. The majority of this work focuses on the use of LC-ES-MS for the determination of unknown products and intermediates formed during electrochemical incineration (ECI), an experimental waste remediation process. This report contains a general introduction to the project and the general conclusions. Four chapters have been removed for separate processing. Titles are: Chapter 2: Determination of small carboxylic acids by ion exclusion chromatography with electrospray mass spectrometry; Chapter 3: Electrochemical incineration of benzoquinone in aqueous media using a quaternary metal oxide electrode in the absence of a soluble supporting electrolyte; Chapter 4: The determination of electrochemical incineration products of 4-chlorophenol by liquid chromatography-electrospray mass spectrometry; and Chapter 5: Determination of small carboxylic acids by capillary electrophoresis with electrospray mass spectrometry.

  3. Solvent extraction, ion chromatography, and mass spectrometry of molybdenum isotopes.

    Science.gov (United States)

    Dauphas, N; Reisberg, L; Marty, B

    2001-06-01

    A procedure was developed that allows precise determination of molybdenum isotope abundances in natural samples. Purification of molybdenum was first achieved by solvent extraction using di(2-ethylhexyl) phosphate. Further separation of molybdenum from isobar nuclides was obtained by ion chromatography using AG1-X8 strongly basic anion exchanger. Finally, molybdenum isotopic composition was measured using a multiple collector inductively coupled plasma hexapole mass spectrometer. The abundances of molybdenum isotopes 92, 94, 95, 96, 97, 98, and 100 are 14.8428(510), 9.2498(157), 15.9303(133), 16.6787(37), 9.5534(83), 24.1346(394), and 9.6104(312) respectively, resulting in an atomic mass of 95.9304(45). After internal normalization for mass fractionation, no variation of the molybdenum isotopic composition is observed among terrestrial samples within a relative precision on the order of 0.00001-0.0001. This demonstrates the reliability of the method, which can be applied to searching for possible isotopic anomalies and mass fractionation.

  4. Liquid chromatography and liquid chromatography-mass spectrometry analysis of donepezil degradation products

    Directory of Open Access Journals (Sweden)

    Mladenović Aleksandar R.

    2015-01-01

    Full Text Available This study describes the investigation of degradation products of donepezil (DP using stability indicating RP-HPLC method for determination of donepezil, which is a centrally acting reversible acetylcholinesterase inhibitor. In order to investigate the stability of drug and formed degradation products, a forced degradation study of drug sample and finished product under different forced degradation conditions has been conducted. Donepezil hydrochloride and donepezil tablets were subjected to stress degradation conditions recommended by International Conference on Harmonization (ICH. Donepezil hydrochloride solutions were subjected to acid and alkali hydrolysis, chemical oxidation and thermal degradation. Significant degradation was observed under alkali hydrolysis and oxidative degradation conditions. Additional degradation products were observed under the conditions of oxidative degradation. The degradation products observed during forced degradation studies were monitored using the high performance liquid chromatography (HPLC method developed. The parent method was modified in order to obtain LC-MS compatible method which was used to identify the degradation products from forced degradation samples using high resolution mass spectrometry. The mass spectrum provided the precise mass from which derived molecular formula of drug substance and degradation products formed and proved the specificity of the method unambiguously. [Projekat Ministarstva nauke Republike Srbije, br. 172013

  5. Characterisation of the volatile profiles of infant formulas by proton transfer reaction-mass spectrometry and gas chromatography-mass spectrometry

    NARCIS (Netherlands)

    Ruth, van S.M.; Floris, V.; Fayoux, S.

    2006-01-01

    The volatile profiles of 13 infant formulas were evaluated by proton transfer reaction-mass spectrometry (PTR-MS) and gas chromatography¿mass spectrometry (GC¿MS). The infant formulas varied in brand (Aptamil, Cow & Gate, SMA), type (for different infant target groups) and physical form (powder/

  6. Enrichment and characterization of phosphopeptides by immobilized metal affinity chromatography (IMAC) and mass spectrometry

    DEFF Research Database (Denmark)

    Thingholm, Tine E; Jensen, Ole N

    2009-01-01

    The combination of immobilized metal affinity chromatography (IMAC) and mass spectrometry is a widely used technique for enrichment and sequencing of phosphopeptides. In the IMAC method, negatively charged phosphate groups interact with positively charged metal ions (Fe3+, Ga3+, and Al3+) and thi......The combination of immobilized metal affinity chromatography (IMAC) and mass spectrometry is a widely used technique for enrichment and sequencing of phosphopeptides. In the IMAC method, negatively charged phosphate groups interact with positively charged metal ions (Fe3+, Ga3+, and Al3...

  7. Comparison of liquid chromatography-microchip/mass spectrometry to conventional liquid chromatography-mass spectrometry for the analysis of steroids.

    Science.gov (United States)

    Ahonen, Linda; Keski-Rahkonen, Pekka; Saarelainen, Taija; Paviala, Jenni; Ketola, Raimo A; Auriola, Seppo; Poutanen, Matti; Kostianen, Risto

    2012-04-01

    The feasibility of a microfluidic-based liquid chromatography-electrospray ionization/mass spectrometric system (HPLC-Chip/ESI/MS) was studied and compared to a conventional narrow-bore liquid chromatography-electrospray ionization/mass spectrometric (LC-ESI/MS) system for the analysis of steroids. The limits of detection (LODs) for oxime derivatized steroids, expressed as concentrations, were slightly higher with the HPLC-Chip/MS system (50-300 pM) using an injection volume of 0.5 μL than with the conventional LC-ESI/MS (10-150 pM) using an injection volume of 40 μL. However, when the LODs are expressed as injected amounts, the sensitivity of the HPLC-Chip/MS system was about 50 times higher than with the conventional LC-ESI/MS system. The results indicate that the use of HPLC-Chip/MS system is clearly advantageous only in the analysis of low-volume samples. Both methods showed good linearity and good quantitative and chromatographic repeatability. In addition to the instrument comparisons with oxime derivatized steroids, the feasibility of the HPLC-Chip/MS system in the analysis of non-derivatized and oxime derivatized steroids was compared. The HPLC-Chip/MS method developed for non-derivatized steroids was also applied to the quantitative analysis of 15 mouse plasma samples.

  8. Different Ways to On-Line Hyphenate Centrifugal Partition Chromatography and Mass Spectrometry: Application to Prenylated Xanthones from Garcinia mangostana.

    Science.gov (United States)

    Destandau, Emilie; Michel, Thomas; Toribio, Alix; Elfakir, Claire

    2015-11-01

    Centrifugal partition chromatography is a liquid-liquid separation method well adapted for the fractionation or purification of natural compounds from plant extracts. However, following the preparative isolation, the fractions collected must be analysed by high-performance thin-layer chromatography or high-performance liquid chromatography to evaluate their composition and/or their purity. These additional steps are time-consuming and increase the risk of compound degradation. In order to get an instantaneous analysis of fraction content with structural information on the phytochemicals eluted, it is possible to hyphenate on-line centrifugal partition chromatography with mass spectrometry. Depending on the complexity of the extract, two different kinds of centrifugal partition chromatography-mass spectrometry coupling can be performed: centrifugal partition chromatography-mass spectrometry or centrifugal partition chromatography-high-performance liquid chromatography-mass spectrometry coupling. In the first case, one part of the centrifugal partition chromatography effluent is directly introduced in the mass spectrometry ionisation source to identify the eluted compounds, while in the second case, it is directed to a high-performance liquid chromatography-mass spectrometry system where compounds are first separated thanks to high-performance liquid chromatography and then identified using mass spectrometry.

  9. Molecular mass ranges of coal tar pitch fractions by mass spectrometry and size-exclusion chromatography.

    Science.gov (United States)

    Karaca, F; Morgan, T J; George, A; Bull, I D; Herod, A A; Millan, M; Kandiyoti, R

    2009-07-01

    A coal tar pitch was fractionated by solvent solubility into heptane-solubles, heptane-insoluble/toluene-solubles (asphaltenes), and toluene-insolubles (preasphaltenes). The aim of the work was to compare the mass ranges of the different fractions by several different techniques. Thermogravimetric analysis, size-exclusion chromatography (SEC) and UV-fluorescence spectroscopy showed distinct differences between the three fractions in terms of volatility, molecular size ranges and the aromatic chromophore sizes present. The mass spectrometric methods used were gas chromatography/mass spectrometry (GC/MS), pyrolysis/GC/MS, electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS) and laser desorption time-of-flight mass spectrometry (LD-TOFMS). The first three techniques gave good mass spectra only for the heptane-soluble fraction. Only LDMS gave signals from the toluene-insolubles, indicating that the molecules were too involatile for GC and too complex to pyrolyze into small molecules during pyrolysis/GC/MS. ESI-FTICRMS gave no signal for toluene-insolubles probably because the fraction was insoluble in the methanol or acetonitrile, water and formic acid mixture used as solvent to the ESI source. LDMS was able to generate ions from each of the fractions. Fractionation of complex samples is necessary to separate smaller molecules to allow the use of higher laser fluences for the larger molecules and suppress the formation of ionized molecular clusters. The upper mass limit of the pitch was determined as between 5000 and 10,000 u. The pitch asphaltenes showed a peak of maximum intensity in the LDMS spectra at around m/z 400, in broad agreement with the estimate from SEC. The mass ranges of the toluene-insoluble fraction found by LDMS and SEC (400-10,000 u with maximum intensity around 2000 u by LDMS and 100-9320 u with maximum intensity around 740 u by SEC) are higher than those for the asphaltene fraction (200-4000 u with

  10. Evaluation of three gas chromatography and two direct mass spectrometry techniques for aroma analysis of dried red bell peppers

    NARCIS (Netherlands)

    Ruth, van S.M.; Boscaini, E.; Mayr, D.; Pugh, J.; Posthumus, M.A.

    2003-01-01

    Three gas chromatography methods and two direct mass spectrometry techniques were compared for the analysis of the aroma of rehydrated diced red bell peppers. Gas chromatography methods included systems with olfactometry detection (GC-O), flame ionisation detection (GC-FID) and mass spectrometry (GC

  11. Identifying Ca2+-Binding Sites in Proteins by Liquid Chromatography-Mass Spectrometry Using Ca2+-Directed Dissociations

    NARCIS (Netherlands)

    Jamalian, Azadeh; Sneekes, Evert-Jan; Wienk, Hans; Dekker, Lennard J. M.; Ruttink, Paul J. A.; Ursem, Mario; Luider, Theo M.; Burgers, Peter C.

    2014-01-01

    Here we describe a new method to identify calcium-binding sites in proteins using high-resolution liquid chromatography-mass spectrometry in concert with calcium-directed collision-induced dissociations. Our method does not require any modifications to the liquid chromatography-mass spectrometry app

  12. Highly sensitive detection of melamine based on reversed phase liquid chromatography mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    WU QingQing; FAN KeXin; SHA Wei; RUAN HongQiang; ZENG Rong; SHIEH ChiaHui

    2009-01-01

    In this work, we developed a highly sensitive method to detect melamine based on reversed phase liquid chromatography mass spectrometry. A mass spectrometry compatible ion pair, heptafluorobu-tyric acid(HFBA), was used to separate melamine by reversed phase liquid chromatography prior to electrospray mass spectrometry. The incorporation of isotope internal standard and multiple reaction monitoring improved the accuracy and linearity of quantification. Based on this strategy, the method limit of quantification was 0.1 ng/g. The limits of quantification were 8 ng/g for liquid milk and 15 ng/g for dry milk powder. This method provided a reproducible and stable approach to sensitive detection and quantification of melamine.

  13. Monitoring stevioside in soju by high-performance liquid chromatography and liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Ni, Fan; Ammann, Jeffrey; Mabud, Abdul

    2007-01-01

    A method using high-performance liquid chromatography (HPLC) with UV absorption detection was developed to monitor stevioside in soju, a distilled spirits product that is commercially available. The method uses a single-step dilution for sample preparation. It completely eliminates the time-consuming process of solid-phase extraction. A method using HPLC/mass spectrometry was optimized to confirm the identities of stevioside and other related impurities, including rebaudioside A, rebaudioside C, and dulcoside. The method was validated. The validation parameters included range (10.1-1007.3 ppm), precision, linearity, accuracy, robustness, system suitability, and intermediate precision. Stevioside standard solutions at 6 concentration levels were prepared for the validation work, including the tests for precision, linearity, and accuracy. The solutions were prepared in triplicate for each concentration. The relative standard deviation for the precision test was 0.999. The average recovery ranged from 95.7 to 101.1% for the soju samples spiked with stevioside standard. The detection limit for stevioside was estimated at 75 ppb. The method was used to screen several soju samples; no detectable stevioside was found in the samples.

  14. Determination of daminozide in apples and apple leaves by liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Mol, H.G.J.; Dam, R.C.J. van; Vreeken, R.J.; Steijger, O.M.

    1999-01-01

    A straightforward and efficient method was developed for the determination of intact daminozide in apples and apple leaves. After extraction with methanol and a clean-up step using a graphitized carbon cartridge, the extract was analysed by ion-trap liquid chromatography-tandem mass spectrometry (LC

  15. Characterization of typical chemical background interferences in atmospheric pressure ionization liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Guo, Xinghua; Bruins, Andries P.; Covey, Thomas R.

    2006-01-01

    The structures and origins of typical chemical background noise ions in positive atmospheric pressure ionization liquid chromatography/mass spectrometry (API LC/MS) are investigated and summarized in this study. This was done by classifying chemical background ions using precursor and product ion sc

  16. Characterization of Pentachlorophenol in Soil by Liquid Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    JIN Mi-cong; WANG Biao

    2004-01-01

    A simple, accurate and sensitive method for characterization of pentachlorophenol in soil was presented. The method included Soxhlet extraction using extracting agent of methanol/water/triethylamine (80∶20∶2), decontamination using solid-phase extraction (SPE) column and characterization by liquid chromatography-mass spectrometry (LCMS). The developed analytical method was successfully used to the determination of pentachlorophenol in soil samples.

  17. Ion-pairing reversed-phased chromatography/mass spectrometry of heparin

    DEFF Research Database (Denmark)

    Henriksen, Jens; Roepstorff, Peter; Ringborg, Lene Hoffmeyer

    2006-01-01

    not well characterised. In order to further characterise such mixtures, two on-line ion-pairing reverse-phased chromatography electrospray ionisation (ESI) mass spectrometry methods have been developed. One of the systems allows the determination of more than 200 components in a medium molecular weight...

  18. The role of liquid chromatography-tandem mass spectrometry in the clinical laboratory

    NARCIS (Netherlands)

    van den Ouweland, Johannes M. W.; Kema, Ido P.

    2012-01-01

    Liquid chromatography coupled to mass spectrometry (LC-MS/MS) is increasingly used as a routine methodology in clinical laboratories for the analysis of low molecular weight molecules. The high specificity in combination with high sensitivity and multi-analyte potential makes it an attractive comple

  19. Identification of Synthetic Polymers and Copolymers by Analytical Pyrolysis-Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Kusch, Peter

    2014-01-01

    An experiment for the identification of synthetic polymers and copolymers by analytical pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) was developed and performed in the polymer analysis courses for third-year undergraduate students of chemistry with material sciences, and for first-year postgraduate students of polymer sciences. In…

  20. Simultaneous determination of seven flavonoids in Epimedium by liquid chromatography-tandem mass spectrometry method

    Institute of Scientific and Technical Information of China (English)

    Cai Sheng Wu; Bao Lin Guo; Yu Xin Sheng; Jin Lan Zhang

    2008-01-01

    In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoids, namely epimedin A, epimedin B, epimedin C, icariin, sagittatoside B, 2"-0-rhamnosyl icariside II, and baohuoside I in Epimedium from different sources.

  1. Fully automated screening of veterinary drugs in milk by turbulent flow chromatography and tandem mass spectrometry

    NARCIS (Netherlands)

    Stolker, A.A.M.; Peters, R.J.B.; Zuiderent, R.; DiBussolo, J.M.; Martins, C.P.B.

    2010-01-01

    There is an increasing interest in screening methods for quick and sensitive analysis of various classes of veterinary drugs with limited sample pre-treatment. Turbulent flow chromatography in combination with tandem mass spectrometry has been applied for the first time as an efficient screening met

  2. Confirmatory analysis of acetylgestagens in plasma using liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Mortensen, Sarah Kelly; Pedersen, Mikael

    2007-01-01

    -assisted liquid-liquid extraction (LLE) on Extrelut NT columns followed by C18 solid-phase extraction (SPE). Analytes were analysed using liquid chromatography-tandem mass spectrometry (I-C-MS/MS), and quantification was performed using matrix-matched calibration standards in combination with deuterated internal...

  3. Incorporation of Gas Chromatography-Mass Spectrometry into the Undergraduate Organic Chemistry Laboratory Curriculum

    Science.gov (United States)

    Giarikos, Dimitrios G.; Patel, Sagir; Lister, Andrew; Razeghifard, Reza

    2013-01-01

    Gas chromatography-mass spectrometry (GC-MS) is a powerful analytical tool for detection, identification, and quantification of many volatile organic compounds. However, many colleges and universities have not fully incorporated this technique into undergraduate teaching laboratories despite its wide application and ease of use in organic…

  4. Coupling of electrokinetic chromatography and mass spectrometry for profiling of drugs

    NARCIS (Netherlands)

    Mol, R.

    2007-01-01

    In this thesis the potential of electrokinetic chromatography (EKC) – mass spectrometry (MS) has been evaluated, including its applicability to the impurity profiling of drugs. Over the past years, capillary zone electrophoresis (CZE) and EKC have gained acceptance as separation techniques next to l

  5. Simultaneous quantitative analysis of metabolites using ion-pair liquid chromatography-electrospray ionization mass spectrometry

    NARCIS (Netherlands)

    Coulier, L.; Bas, R.; Jespersen, S.; Verheij, E.; Werf, M.J. van der; Hankemeier, T.

    2006-01-01

    We have developed an analytical method, consisting of ion-pair liquid chromatography coupled to electrospray ionization mass spectrometry (IP-LC-ESI-MS), for the simultaneous quantitative analysis of several key classes of polar metabolites, like nucleotides, coenzyme A esters, sugar nucleotides, an

  6. Impurity profiling of trinitrotoluene using vacuum-outlet gas chromatography-mass spectrometry

    NARCIS (Netherlands)

    Brust, H.; Willemse, S.; Zeng, T.; Asten, A. van; Koeberg, M.; Heijden, A.E.D.M. van der; Bolck, A.; Schoenmakers, P.

    2014-01-01

    In this work, a reliable and robust vacuum-outlet gas chromatography-mass spectrometry (GC-MS) method is introduced for the identification and quantification of impurities in trinitrotoluene (TNT). Vacuum-outlet GC-MS allows for short analysis times the analysis of impurities in TNT was performed in

  7. Determination of organophosphorus acids by thermo-spray liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Wils, E.R.J.; Hulst, A.G.

    1988-01-01

    The determination of thirteen organophosphorus acids, hydrolysis products of nerve agents and pesticides, by a combination of ion-pair liquid chromatography on a reversed-phase C18 column and thermospray mass spectrometry was investigated. Ammonium acetate and three tetraalkylammonium salts with dif

  8. Liquid chromatography-quadrupole-time-of-flight mass spectrometry screening procedure for urine samples in forensic casework compared to gas chromatography-mass spectrometry.

    Science.gov (United States)

    Fels, Helena; Dame, Torsten; Sachs, Hans; Musshoff, Frank

    2016-07-04

    This work represents the development, validation, and application of a liquid chromatography-quadrupole-time-of-flight mass spectrometry (LC-QTOF-MS) screening method for the detection of pharmaceutical substances and illicit drugs (acidic, basic, and neutral organic drugs) in urine samples. Time-of-flight mass spectrometry was performed using an LC-Triple TOF 5600 system with electrospray ionization operated in both positive and negative mode, respectively. The limits of detection (LODs), determined for 34 substances, were 70%). These four parameters served as identification criteria and are discussed according to their role in identifying compounds even without reference substances. In routine casework, two in-house XIC (extracted ion chromatogram) lists, consisting of 456 protonated and 26 deprotonated compounds were used and retention times for 365 compounds were available. Compared to the results found with the established gas chromatography-mass spectrometry (GC-MS) procedure, the findings with the LC-QTOF-MS screening method showed a good comparability. Results that were not detected by LC-QTOF-MS because of a missing entry in the targeted XIC list could retrospectively be confirmed by simply entering the elemental formula of the relevant substance into the software and reprocessing the sample. LC-QTOF-MS offers an attractive technique for the fast and specific identification of illicit drugs and toxic compounds in urine samples. Copyright © 2016 John Wiley & Sons, Ltd.

  9. Characterisation of beeswax in works of art by gas chromatography-mass spectrometry and pyrolysis-gas chromatography-mass spectrometry procedures.

    Science.gov (United States)

    Bonaduce, Ilaria; Colombini, Maria Perla

    2004-03-05

    Pyrolysis (Py) with in situ derivatisation with hexamethyldisilazane-gas chroma-break tography-mass spectrometry (GC-MS) and a gas chromatography-mass spectrometry procedure based on microwave-assisted saponification were used to identify the organic components in small sized beeswax samples. With the latter procedure quantitative recoveries can be made and hydrocarbons, alcohols and omega-1-diols in the neutral fraction, and fatty acids and omega-1-hydroxy acids in the acidic fraction can be efficiently separated and detected. Both procedures were used to characterise a wax anatomic sculpture "The Plague" (1691-1694) by Gaetano Zumbo, resulting in the identification of beeswax and a Pinaceae resin. The GC-MS analysis brought to light some essential differences in beeswax composition between the raw material and the old modelled wax thus giving some clear indications about the recipe used by the sculptor.

  10. The bridge between thin layer chromatography-mass spectrometry and high-performance liquid chromatography-mass spectrometry: The realization of liquid thin layer chromatography-mass spectrometry (LTLC-MS).

    Science.gov (United States)

    Li, Yafeng; Wang, Jianing; Zhan, Lingpeng; Wleklinski, Michael; Wang, Jiyun; Xiong, Caiqiao; Liu, Huihui; Zhou, Yueming; Nie, Zongxiu

    2016-08-19

    The combination of thin layer chromatography (TLC) and mass spectrometry (MS) has been studied for decades, but for most cases MS detection is done after TLC separation is finished. Here, an online simultaneous TLC-MS analysis system, liquid thin layer chromatography-mass spectrometry (LTLC-MS), is developed which successfully synchronize TLC separation process and MS detection process like GC-MS and HPLC-MS do. And there's no need to use specially designed TLC, just regular TLC plates are enough. LTLC-MS method is composed of a newly developed ambient ionization method, glow discharge-matrix assisted infrared desorption ionization (GD-MAIRDI), and forced-flow TLC (FFTLC) technique, which guarantees the MS detection process does not disturb the TLC separation process throughout the whole analysis. The whole LTLC-MS analysis only need two steps and less than 15min. Mixtures as well as the two main components of a pain relief pills have been successfully analyzed by LTLC-MS. This proof of concept study opens up new possibilities of combining TLC with MS, and will further broaden the application abilities of TLC.

  11. Validation of a confirmatory method for the determination of melamine in egg by gas chromatography-mass spectrometry and ultra-performance liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Xia Xi; Ding Shuangyang; Li Xiaowei; Gong Xiao; Zhang Suxia; Jiang Haiyang; Li Jiancheng [Department of Pharmacology and Toxicology, College of Veterinary Medicine, China Agricultural University, Beijing 100193 (China); Shen Jianzhong, E-mail: sjz@cau.edu.cn [Department of Pharmacology and Toxicology, College of Veterinary Medicine, China Agricultural University, Beijing 100193 (China)

    2009-10-05

    A sensitive and reliable method was developed and validated for detection and confirmation of melamine in egg based on gas chromatography-mass spectrometry (GC-MS) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Trichloroacetic acid solution was used for sample extraction and precipitation of proteins. The aqueous extracts were subjected to solid-phase extraction by mixed-mode reversed-phase/strong cation-exchange cartridges. Using ultra-performance liquid chromatography and electrospray ionization in the positive ion mode, melamine was determined by LC-MS/MS, which was completed in 5 min for each injection. For the GC-MS analysis, extracted melamine was derivatized with N,O-bis(trimethylsilyl)trifluoracetamide prior to selected ion monitoring detection in electron impact mode. The average recovery of melamine from fortified samples ranged from 85.2% to 103.2%, with coefficients of variation lower than 12%. The limit of detection obtained by GC-MS and UPLC-MS/MS was 10 and 5 {mu}g kg{sup -1}, respectively. This validated method was successfully applied to the determination of melamine in real samples from market.

  12. Characterization of goat colostrum oligosaccharides by nano-liquid chromatography on chip quadrupole time-of-flight mass spectrometry and hydrophilic interaction liquid chromatography-quadrupole mass spectrometry.

    Science.gov (United States)

    Martín-Ortiz, A; Salcedo, J; Barile, D; Bunyatratchata, A; Moreno, F J; Martin-García, I; Clemente, A; Sanz, M L; Ruiz-Matute, A I

    2016-01-08

    A detailed qualitative and quantitative characterization of goat colostrum oligosaccharides (GCO) has been carried out for the first time. Defatted and deproteinized colostrum samples, previously treated by size exclusion chromatography (SEC) to remove lactose, were analyzed by nanoflow liquid chromatography-quadrupole-time of flight mass spectrometry (Nano-LC-Chip-Q-TOF MS). Up to 78 oligosaccharides containing hexose, hexosamine, fucose, N-acetylneuraminic acid or N-glycolylneuraminic acid monomeric units were identified in the samples, some of them detected for the first time in goat colostra. As a second step, a hydrophilic interaction liquid chromatography coupled to mass spectrometry (HILIC-MS) methodology was developed for the separation and quantitation of the main GCO, both acidic and neutral carbohydrates. Among other experimental chromatographic conditions, mobile phase additives and column temperature were evaluated in terms of retention time, resolution, peak width and symmetry of target carbohydrates. Narrow peaks (wh: 0.2-0.6min) and good symmetry (As: 0.8-1.4) were obtained for GCO using an acetonitrile:water gradient with 0.1% ammonium hydroxide at 40°C. These conditions were selected to quantify the main oligosaccharides in goat colostrum samples. Values ranging from 140 to 315mgL(-1) for neutral oligosaccharides and from 83 to 251mgL(-1) for acidic oligosaccharides were found. The combination of both techniques resulted to be useful to achieve a comprehensive characterization of GCO.

  13. Analysis of acrylamide in cooked foods by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Rosén, Johan; Hellenäs, Karl-Erik

    2002-07-01

    A method using liquid chromatography tandem mass spectrometry (LC-MS-MS) with electrospray for the analysis of acrylamide in foods is reported. The method comprises the addition of deuterium-labelled acrylamide-d3, extraction with water, mixed mode solid phase extraction, ultrafiltration and a graphitised carbon column for chromatography. The transitions m/z 72 > 55, 72 > 54, 72 > 44, 72 > 27, 72 > 72 and 75 > 58 were recorded in multiple reaction monitoring mode for identification and quantification. In-house validation data for products from potatoes and cereals (30 to 10,000 microg kg(-1)) are presented (accuracy 91 to 102%, relative standard deviation 3 to 21%). Interlaboratory validation data (comparison with gas chromatography mass spectrometry, 25 to 2000 microg kg(-1)) showed excellent results (r2 = 0.998).

  14. Arsenic speciation by liquid chromatography coupled with ionspray tandem mass spectrometry

    DEFF Research Database (Denmark)

    Corr, J. J.; Larsen, Erik Huusfeldt

    1996-01-01

    fragmentation patterns showing molecular dissociation through an expected common product ion were obtained for the four arsenosugars, Molecular mode detection was utilized for qualitative verification of speciation analysis by high-performance liquid chromatography coupled to inductively coupled plasma mass......Ionspray mass spectrometry, a well established organic analysis technique, has been coupled to high-performance liquid chromatography for speciation of organic arsenic compounds, The ionspray source and differentially pumped interface of the mass spectrometer were operated in dual modes...... for elemental and molecular analysis, Tandem mass spectrometry was employed to increase selectivity, Dual mode detection was applied to demonstrate the utility of the technique for analysis of nine organoarsenic standards, including four dimethylarsinylriboside derivatives (arsenosugars), Structural...

  15. Screening Non-colored Phenolics in Red Wines using Liquid Chromatography/Ultraviolet and Mass Spectrometry/Mass Spectrometry Libraries

    Directory of Open Access Journals (Sweden)

    Changqing Duan

    2007-03-01

    Full Text Available Liquid chromatography/ultraviolet (LC/UV and mass spectrometry/mass spectrometry (MS/MS libraries containing 39 phenolic compounds were established by coupling a LC and an ion trap MS with an electrospray ionization (ESI source, operated in negative ion mode. As a result, the deprotonated [M-H]- molecule was observed for all the analyzed compounds. Using MS/MS hydroxybenzoic acid and hydroxycinnamic acids showed a loss of CO2 and production of a [M-H-44] - fragment and as expected, the UV spectra of these two compounds were affected by their chemical structures. For flavonol and flavonol glycosides, the spectra of their glycosides and aglycones produced deprotonated [M-H]- and [A-H]- species, respectively, and their UV spectra each presented two major absorption peaks. The UV spectra and MS/MS data of flavan-3-ols and stilbenes were also investigated. Using the optimized LC/MS/MS analytical conditions, the phenolic extracts from six representative wine samples were analyzed and 31 phenolic compounds were detected, 26 of which were identified by searching the LC/UV and MS/MS libraries. Finally, the presence of phenolic compounds was confirmed in different wine samples using the LC/UV and LC/MS/MS libraries.

  16. Analysis of ganciclovir and its related substances using high performance liquid chromatography and liquid chromatography-mass spectrometry methods

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all r...

  17. Quantitative Analysis of Tetramethylenedisulfotetramine ("Tetramine") Spiked into Beverages by Liquid Chromatography Tandem Mass Spectrometry with Validation by Gas Chromatography Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Owens, J; Hok, S; Alcaraz, A; Koester, C

    2008-11-13

    Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limit of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.

  18. Detection of Stimulants and Narcotics by Liquid Chromatography-Tandem Mass Spectrometry and Gas Chromatography-Mass Spectrometry for Sports Doping Control.

    Science.gov (United States)

    Ahrens, Brian D; Kucherova, Yulia; Butch, Anthony W

    2016-01-01

    Sports drug testing laboratories are required to detect several classes of compounds that are prohibited at all times, which include anabolic agents, peptide hormones, growth factors, beta-2 agonists, hormones and metabolic modulators, and diuretics/masking agents. Other classes of compounds such as stimulants, narcotics, cannabinoids, and glucocorticoids are also prohibited, but only when an athlete is in competition. A single class of compounds can contain a large number of prohibited substances and all of the compounds should be detected by the testing procedure. Since there are almost 70 stimulants on the prohibited list it can be a challenge to develop a single screening method that will optimally detect all the compounds. We describe a combined liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) testing method for detection of all the stimulants and narcotics on the World Anti-Doping Agency prohibited list. Urine for LC-MS/MS testing does not require sample pretreatment and is a direct dilute and shoot method. Urine samples for the GC-MS method require a liquid-liquid extraction followed by derivatization with trifluoroacetic anhydride.

  19. Gas Chromatography/Atmospheric Pressure Chemical Ionization Tandem Mass Spectrometry for Fingerprinting the Macondo Oil Spill.

    Science.gov (United States)

    Lobodin, Vladislav V; Maksimova, Ekaterina V; Rodgers, Ryan P

    2016-07-05

    We report the first application of a new mass spectrometry technique (gas chromatography combined to atmospheric pressure chemical ionization tandem mass spectrometry, GC/APCI-MS/MS) for fingerprinting a crude oil and environmental samples from the largest accidental marine oil spill in history (the Macondo oil spill, the Gulf of Mexico, 2010). The fingerprinting of the oil spill is based on a trace analysis of petroleum biomarkers (steranes, diasteranes, and pentacyclic triterpanes) naturally occurring in crude oil. GC/APCI enables soft ionization of petroleum compounds that form abundant molecular ions without (or little) fragmentation. The ability to operate the instrument simultaneously in several tandem mass spectrometry (MS/MS) modes (e.g., full scan, product ion scan, reaction monitoring) significantly improves structural information content and sensitivity of analysis. For fingerprinting the oil spill, we constructed diagrams and conducted correlation studies that measure the similarity between environmental samples and enable us to differentiate the Macondo oil spill from other sources.

  20. Atmospheric pressure chemical ionisation liquid chromatography/mass spectrometry of bacteriochlorophylls from Chlorobiaceae: characteristic fragmentations.

    Science.gov (United States)

    Airs, Ruth L; Keely, Brendan J

    2002-01-01

    Atmospheric pressure chemical ionisation liquid chromatography/mass spectrometry/mass spectrometry (APCI-LC/MS/MS) has been applied to the study of bacteriochlorophylls c, d, and e of phototrophic prokaryotes. Cultures of Chlorobiaceae containing bacteriochlorophyll c, d or e were examined using a high-resolution high-performance liquid chromatography (HPLC) method and APCI-LC/MS/MS employing post-column addition of formic acid. The results reveal complex distributions of bacteriochlorophyll homologues, with some closely eluting species giving isobaric protonated molecules. On-line LC/MS/MS studies reveal characteristic fragment ions for bacteriochlorophylls c, d, and e. Fragmentations involving loss of the extended alkyl substituents that are unique to bacteriochlorophylls c, d and e and their derivatives have been rationalised by studying the phaeophorbides and the results applied to the direct study of the bacteriochlorophylls.

  1. Determination of diclofenac concentrations in human plasma using a sensitive gas chromatography mass spectrometry method

    OpenAIRE

    2016-01-01

    Background A gas chromatography mass spectrometry (GCMS) method for the determination of diclofenac in human plasma has been developed and validated. Results This method utilizes hexane which is a relatively less toxic extraction solvent compared to heptane and benzene. In addition, phosphoric acid and acetone were added to the samples as deproteination agents, which increased the recovery of diclofenac. These revised processes allow clean extraction and near-quantitative recovery of analyte ...

  2. Determination of diclofenac concentrations in human plasma using a sensitive gas chromatography mass spectrometry method

    OpenAIRE

    Shah, Iltaf; Barker, James; Naughton, Declan P; Barton, Stephen J.; Ashraf, Syed Salman

    2016-01-01

    Background\\ud A gas chromatography mass spectrometry (GCMS) method for the determination of diclofenac in human plasma has been developed and validated.\\ud \\ud Results\\ud This method utilizes hexane which is a relatively less toxic extraction solvent compared to heptane and benzene. In addition, phosphoric acid and acetone were added to the samples as deproteination agents, which increased the recovery of diclofenac. These revised processes allow clean extraction and near-quantitative recover...

  3. Evaluation of noni (Morinda citrifolia) volatile profile by dynamic headspace and gas chromatography-mass spectrometry

    OpenAIRE

    Sousa, A.; M. A. SOUZA NETO; GARRUTI, D. dos S.; Sousa, J. A.; BRITO, E. S. de

    2010-01-01

    Noni is a fruit that has interested the scientific community due to its medicinal and functional activities. Different products that contain noni are already in the market, but their consumption could be impaired by their distinctive unpleasant aroma and flavor. The aim of this work was to evaluate the noni pulp volatile profile by dynamic headspace and gas chromatography-mass spectrometry. Thirty seven volatile compounds were detected, mainly alcohols (63.3%), esters (26.9%), cetones (7.4%),...

  4. Isotope-Dilution Mass Spectrometry for Quantification of Urinary Active Androgens Separated by Gas Chromatography

    OpenAIRE

    Su Hyeon Lee; Man Ho Choi; Won-Yong Lee; Bong Chul Chung

    2010-01-01

    Cross reacting antibodies can cause an overestimation of the results of immunoassays. Therefore, alternative methodsare needed for the accurate quantification of steroids. Gas chromatography combined with isotope-dilution mass spectrometry(GC-IDMS) is developed to quantify urinary active androgens, testosterone, epitestosterone and dihydrotestosterone, which areclinically relevant androgens to both hair-loss and prostate diseases. The method devised involves enzymatic hydrolysis with β-glucur...

  5. Analysis of 23 polycyclic aromatic hydrocarbons in smokeless tobacco by gas chromatography-mass spectrometry

    OpenAIRE

    Stepanov, Irina; Villalta, Peter W.; Knezevich, Aleksandar; Jensen, Joni; Hatsukami, Dorothy; Hecht, Stephen S.

    2010-01-01

    Smokeless tobacco contains 28 known carcinogens and causes precancerous oral lesions and oral and pancreatic cancer. A recent study conducted by our research team identified 8 different polycyclic aromatic hydrocarbons (PAH) in U.S. moist snuff, encouraging further investigations of this group of toxicants and carcinogens in smokeless tobacco products. In this study, we developed a gas chromatography-mass spectrometry method that allows simultaneous analysis of 23 various PAH in smokeless tob...

  6. Measurement of abscisic acid and gibberellins by gas chromatography/mass spectrometry.

    Science.gov (United States)

    Okamoto, Masanori; Hanada, Atsushi; Kamiya, Yuji; Yamaguchi, Shinjiro; Nambara, Eiji

    2009-01-01

    Gas chromatography-mass spectrometry (GC-MS)-based analysis is an accurate and sensitive method to quantify plant hormones. This method is commonly used for analysis of low-molecular-weight compounds, such as abscisic acid (ABA), gibberellins (GAs), auxins, and brassinosteroids. Procedures are composed of four major steps: extraction, fractionation, derivatization, and detection. Here, we describe a protocol for quantification of ABA and GAs.

  7. Analysis of glyphosate residues in cereals using liquid chromatography-mass spectrometry (LC-MS/MS)

    DEFF Research Database (Denmark)

    Granby, Kit; Johannesen, S.; Gabrielsen, Martin Vahl

    2003-01-01

    A fast and specific method for the determination of glyphosate in cereals is described. The method is based on extraction with water by ultrasonication. The samples are cleaned up and separated by high-performance liquid chromatography on a polystyrene-based reverse-phase column (clean......-up) in series with an ion chromatography column (separation) using NaHCO3 as eluent. A micro-membrane suppressor was inserted after the separator column to remove the Na + ions before detection by electrospray ionization mass spectrometry in the negative-ion mode. In MS/MS, mode the following transitions were...

  8. Quantitative analysis of multiple components based on liquid chromatography with mass spectrometry in full scan mode.

    Science.gov (United States)

    Xu, Min Li; Li, Bao Qiong; Wang, Xue; Chen, Jing; Zhai, Hong Lin

    2016-08-01

    Although liquid chromatography with mass spectrometry in full scan mode can obtain all the signals simultaneously in a large range and low cost, it is rarely used in quantitative analysis due to several problems such as chromatographic drifts and peak overlap. In this paper, we propose a Tchebichef moment method for the simultaneous quantitative analysis of three active compounds in Qingrejiedu oral liquid based on three-dimensional spectra in full scan mode of liquid chromatography with mass spectrometry. After the Tchebichef moments were calculated directly from the spectra, the quantitative linear models for three active compounds were established by stepwise regression. All the correlation coefficients were more than 0.9978. The limits of detection and limits of quantitation were less than 0.11 and 0.49 μg/mL, respectively. The intra- and interday precisions were less than 6.54 and 9.47%, while the recovery ranged from 102.56 to 112.15%. Owing to the advantages of multi-resolution and inherent invariance properties, Tchebichef moments could provide favorable results even in the situation of peaks shifting and overlapping, unknown interferences and noise signals, so it could be applied to the analysis of three-dimensional spectra in full scan mode of liquid chromatography with mass spectrometry.

  9. Review of in situ derivatization techniques for enhanced bioanalysis using liquid chromatography with mass spectrometry.

    Science.gov (United States)

    Baghdady, Yehia Z; Schug, Kevin A

    2016-01-01

    Accurate and specific analysis of target molecules in complex biological matrices remains a significant challenge, especially when ultra-trace detection limits are required. Liquid chromatography with mass spectrometry is often the method of choice for bioanalysis. Conventional sample preparation and clean-up methods prior to the analysis of biological fluids such as liquid-liquid extraction, solid-phase extraction, or protein precipitation are time-consuming, tedious, and can negatively affect target recovery and detection sensitivity. An alternative or complementary strategy is the use of an off-line or on-line in situ derivatization technique. In situ derivatization can be incorporated to directly derivatize target analytes in their native biological matrices, without any prior sample clean-up methods, to substitute or even enhance the extraction and preconcentration efficiency of these traditional sample preparation methods. Designed appropriately, it can reduce the number of sample preparation steps necessary prior to analysis. Moreover, in situ derivatization can be used to enhance the performance of the developed liquid chromatography with mass spectrometry-based bioanalysis methods regarding stability, chromatographic separation, selectivity, and ionization efficiency. This review presents an overview of the commonly used in situ derivatization techniques coupled to liquid chromatography with mass spectrometry-based bioanalysis to guide and to stimulate future research.

  10. Characterization of oil sands process-affected waters by liquid chromatography orbitrap mass spectrometry.

    Science.gov (United States)

    Pereira, Alberto S; Bhattacharjee, Subir; Martin, Jonathan W

    2013-05-21

    Recovery of bitumen from oil sands in northern Alberta, Canada, occurs by surface mining or in situ thermal recovery, and both methods produce toxic oil sands process-affected water (OSPW). A new characterization strategy for surface mining OSPW (sm-OSPW) and in situ OSPW (is-OSPW) was achieved by combining liquid chromatography with orbitrap mass spectrometry (MS). In electrospray positive and negative ionization modes (ESI(+)/ESI(-)), mass spectral data were acquired with high resolving power (RP > 100,000-190,000) and mass accuracy (method should be further applied to environmental forensic analysis of water in the region.

  11. Novel liquid chromatography tandem mass spectrometry (LC-MS/MS) methods for measuring steroids.

    Science.gov (United States)

    Keevil, Brian G

    2013-10-01

    Liquid chromatography tandem mass spectrometry (LC-MS/MS) is increasingly becoming the method of choice for steroid hormone measurements due to small sample volumes, fast analysis times and improved specificity compared to immunoassays. Achievement of demanding analytical targets for steroid analysis is now becoming possible because of improvements in sample preparation technology, liquid chromatography column technology and mass spectrometer design. The most popular sample treatment strategies comprise protein precipitation (PP), solid-phase extraction (SLE) and liquid-liquid extraction (LLE). Modern liquid chromatography columns can ensure the adequate separation of isobaric compounds e.g. 21 Deoxycortisol, 11 Deoxycortisol and Corticosterone. The most appropriate method may be chosen to improve assay sensitivity by reducing matrix effects (LLE, SPE) or simplicity and speed (PP). Specific examples of some clinically important steroids including oestradiol, aldosterone, renin, serum cortisol, salivary cortisol and salivary testosterone will be described.

  12. Analysis of pesticide residues in tobacco with online size exclusion chromatography with gas chromatography and tandem mass spectrometry.

    Science.gov (United States)

    Guo, Weiyun; Bian, Zhaoyang; Tang, Gangling; Wang, Deguo; Li, Guanghui; Wang, Jianlong

    2016-07-01

    An ultrasensitive method for the simultaneous analysis of pesticides residues in tobacco was developed with online size exclusion chromatography with gas chromatography and tandem mass spectrometry. Tobacco samples were extracted with the solvent mixture of cyclohexane and acetone (7:3, v/v) and centrifuged. Then, the supernatant liquors were injected directly into the online size exclusion chromatography with gas chromatography and tandem mass spectrometry without any other purification procedures after being filtered with a 0.22 μm organic phase filter. The matrix interferences were effectively removed and recoveries of most pesticides were in the range of 72-121%. Especially, for chlorothalonil, the analysis efficiency of this method was much more favorable than that of the general method, in which dispersive solid-phase extraction was used as an additional purified procedure. In addition, the limits of quantitation of this method were from 1 to 50 μg/kg. Therefore, a rapid, cost-effective, labor-saving method was proposed in the present work, which was suitable for the analysis of 41 pesticide residues in tobacco.

  13. Detailed molecular characterization of castor oil ethoxylates by liquid chromatography multistage mass spectrometry.

    Science.gov (United States)

    Nasioudis, Andreas; van Velde, Jan W; Heeren, Ron M A; van den Brink, Oscar F

    2011-10-07

    The molecular characterization of castor oil ethoxylates (CASEOs) was studied by reverse-phase liquid chromatography (RPLC) mass spectrometry (MS) and multistage mass spectrometry (MS(n)). The developed RPLC method allowed the separation of the various CASEO components, and especially, the baseline separation of multiple nominal isobars (same nominal mass) and isomers (same exact mass). MS and MS(n) were used for the determination and structure elucidation of various structures and for the discrimination of the isobars and isomers. Different ionization techniques and adduct ions were also tested for optimization of the MS detection and the MS(n) fragmentation. A unique fragmentation pathway of ricinoleic acid is proposed, which can be used as a marker of the polymerization process and the topology of ethoxylation in the CASEO. In addition, characteristic neutral losses of ricinoleic acid reveal its (terminal or internal) position in the molecule.

  14. Isotope Ratio Monitoring Gas Chromatography Mass Spectrometry (IRM-GCMS)

    Science.gov (United States)

    Freeman, K. H.; Ricci, S. A.; Studley, A.; Hayes, J. M.

    1989-01-01

    On Earth, the C-13 content of organic compounds is depleted by roughly 13 to 23 permil from atmospheric carbon dioxide. This difference is largely due to isotope effects associated with the fixation of inorganic carbon by photosynthetic organisms. If life once existed on Mars, then it is reasonable to expect to observe a similar fractionation. Although the strongly oxidizing conditions on the surface of Mars make preservation of ancient organic material unlikely, carbon-isotope evidence for the existence of life on Mars may still be preserved. Carbon depleted in C-13 could be preserved either in organic compounds within buried sediments, or in carbonate minerals produced by the oxidation of organic material. A technique is introduced for rapid and precise measurement of the C-13 contents of individual organic compounds. A gas chromatograph is coupled to an isotope-ratio mass spectrometer through a combustion interface, enabling on-line isotopic analysis of isolated compounds. The isotope ratios are determined by integration of ion currents over the course of each chromatographic peak. Software incorporates automatic peak determination, corrections for background, and deconvolution of overlapped peaks. Overall performance of the instrument was evaluated by the analysis of a mixture of high purity n-alkanes of know isotopic composition. Isotopic values measured via IRM-GCMS averaged withing 0.55 permil of their conventionally measured values.

  15. A New Liquid Chromatography-Tandem Mass Spectrometry Method for Determination of Bisoprolol in Human Plasma Samples

    OpenAIRE

    Gabriela Peste; Nela Bibire; Mihai Apostu; Aurel Vlase; Corneliu Oniscu

    2009-01-01

    Liquid chromatography (LC) coupled with mass spectrometry (MS) detection is one of the most powerful analytical tools for organic compound analysis. The advantages of using LC/MS methods over HPLC methods include: selectivity, chromatographic integrity, peak assignment, structural information, and rapid method development. In this paper, a new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the determination of bisoprolol in human plasma s...

  16. [Determination of glyphosate and aminomethylphosphonic acid residues in foods using high performance liquid chromatography-mass spectrometry/mass spectrometry].

    Science.gov (United States)

    Li, Bo; Deng, Xiaojun; Guo, Dehua; Jin, Shuping

    2007-07-01

    A method for the determination of glyphosate (PMG) and aminomethylphosphonic acid (AMPA) residues in plant products, such as rice, wheat, vegetables, fruits and tea, pig and chicken muscles, aquatic products, chestnut, honey, etc., was developed using high performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS). In this method, PMG and AMPA were extracted with water from samples, defatted using an extraction step with dichloromethane, and purified using a cation-exchange (CAX) solid phase extraction cartridge. Then, these were derived using fluorenylmethylchloroformate (FMOC-Cl) in borate buffer for subsequent HPLC-MS/MS analysis. Isotope-labeled PMG 1, 2(13)- C(15) N was used as the internal standard for the quantitative analysis of two residues. For all samples, the recoveries ranged from 80.0% to 104% and the relative standard deviations (RSDs) ranged from 6.7% to 18.2%. The limit of quantification (LOQ) was determined to be 0.05 mg/kg with a linear range of 0.20-10 microg/L. It is demonstrated that this method is reliable and sensitive for the analysis of PMG and APMA with low concentrations in foods.

  17. Analysis of estrogens and androgens in postmenopausal serum and plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Wang, Qingqing; Bottalico, Lisa; Mesaros, Clementina; Blair, Ian A

    2015-07-01

    Liquid chromatography-selected reaction monitoring/mass spectrometry-based methodology has evolved to the point where accurate analyses of trace levels of estrogens and androgens in postmenopausal serum and plasma can be accomplished with high precision and accuracy. A suite of derivatization procedures has been developed, which together with modern mass spectrometry instrumentation provide investigators with robust and sensitive methodology. Pre-ionized derivatives are proving to be useful as they are not subject to suppression of the electrospray signal. Postmenopausal women with elevated plasma or serum estrogens are thought to be at increased risk for breast and endometrial cancer. Therefore, significant advances in risk assessment should be possible now that reliable methodology is available. It is also possible to conduct analyses of multiple estrogens in plasma or serum. Laboratories that are currently employing liquid chromatography/mass spectrometry methodology can now readily implement this strategy. This will help conserve important plasma and serum samples available in Biobanks, as it will be possible to conduct high sensitivity analyses using low initial sample volumes. Reported levels of both conjugated and non-conjugated estrogen metabolites are close to the limits of sensitivity of many assays to date, urging caution in the interpretation of these low values. The analysis of serum androgen precursors in postmenopausal women has not been conducted routinely in the past using liquid chromatography/mass spectrometry methodology. Integration of serum androgen levels into the panel of metabolites analyzed could provide additional information for assessing cancer risk and should be included in the future.

  18. Determination of macrolide antibiotics in chicken tissues by liquid chromatography-electrospray mass spectrometry

    Science.gov (United States)

    Salikin, Jamilah; Abdullah, Aminah

    2013-11-01

    A methodusingliquid chromatography-electrospray mass spectrometry (LC-(ESI)MS) for the simultaneous determination of three macrolides (tylosin, spiramycin and tilmicosin) in poultry muscle has been developed. The drugs were extracted with EDTA McIlvaine buffer, filter through celite 545 and the extracts were cleaned up by SPE Oasis HLB cartridge. Separation was carried out in end-capped silica-based C18 column and mobile phases containing trifluoroacetic acid-acetonitrile with a binary gradient system at a flow rate 0.5 ml/min. Detection was performed by single mass spectrometry with electrospray ionization in the positive mode. Several parameters affecting the mass spectra were studied. Chicken samples from the market were analyzed to check the residue of macrolide antibiotics.

  19. Tools to discover anionic and nonionic polyfluorinated alkyl surfactants by liquid chromatography electrospray ionisation mass spectrometry

    DEFF Research Database (Denmark)

    Trier, Xenia; Granby, Kit; Christensen, Jan H.

    2011-01-01

    A tiered approach is proposed for the discovery of unknown anionic and nonionic polyfluorinated alkyl surfactants (PFASs) by reversed phase ultra high performance liquid chromatography (UHPLC) – negative electrospray ionisation – quadrupole time of flight mass spectrometry (UHPLC......–ESI−–QTOF–MS). The chromatographic separation, ionisation and detection of PFASs mixtures, was achieved at high pH (pH=9.7) with NH4OH as additive. To distinguish PFASs from other chemicals we used the characteristic negative mass defects of PFASs, their specific losses of 20Da (HF) and the presence of series of chromatographic...

  20. Plasma lipid analysis by hydrophilic interaction liquid chromatography coupled with electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Sonomura, Kazuhiro; Kudoh, Shinobu; Sato, Taka-Aki; Matsuda, Fumihiko

    2015-06-01

    A novel method for the analysis of endogenous lipids and related compounds was developed employing hydrophilic interaction liquid chromatography with electrospray ionization tandem mass spectrometry. A hydrophilic interaction liquid chromatography with carbamoyl stationary phase achieved clear separation of phosphatidylcholine, lysophosphatidylcholine, sphingomyelin, ceramide, and mono-hexsosyl ceramide groups with good peak area repeatability (RSD% 0.99). The established method was applied to human plasma assays and a total of 117 endogenous lipids were successfully detected and reproducibly identified. In addition, we investigated the simultaneous detection of small polar metabolites such as amino and organic acids co-existing in the same biological samples processed in a single analytical run with lipids. Our results show that hydrophilic interaction liquid chromatography is a useful tool for human plasma lipidome analysis and offers more comprehensive metabolome coverage.

  1. Identification of novel circulating coffee metabolites in human plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Redeuil, Karine; Smarrito-Menozzi, Candice; Guy, Philippe; Rezzi, Serge; Dionisi, Fabiola; Williamson, Gary; Nagy, Kornél; Renouf, Mathieu

    2011-07-22

    This study reports a liquid chromatography-mass spectrometry method for the detection of polyphenol-derived metabolites in human plasma without enzymatic treatment after coffee consumption. Separation of available standards was achieved by reversed-phase ultra performance liquid chromatography and detection was performed by high resolution mass spectrometry in negative electrospray ionization mode. This analytical method was then applied for the identification and relative quantification of circulating coffee metabolites. A total of 34 coffee metabolites (mainly reduced, sulfated and methylated forms of caffeic acid, coumaric acid, caffeoylquinic acid and caffeoylquinic acid lactone) were identified based on mass accuracy (<4 ppm for most metabolites), specific fragmentation pattern and co-chromatography (when standard available). Among them, 19 circulating coffee metabolites were identified for the first time in human plasma such as feruloylquinic acid lactone, sulfated and glucuronidated forms of feruloylquinic acid lactone and sulfated forms of coumaric acid. Phenolic acid derivatives such as dihydroferulic acid, dihydroferulic acid 4'-O-sulfate, caffeic acid 3'-O-sulfate, dimethoxycinnamic acid, dihydrocaffeic acid and coumaric acid O-sulfate appeared to be the main metabolites circulating in human plasma after coffee consumption. The described method is a sensitive and reliable approach for the identification of coffee metabolites in biological fluids. In future, this analytical method will give more confidence in compound identification to provide a more comprehensive assessment of coffee polyphenol bioavailability studies in humans.

  2. Morphine brain pharmacokinetics at very low concentrations studied with accelerator mass spectrometry and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Sadiq, Muhammad Waqas; Salehpour, Mehran; Forsgard, Niklas; Possnert, Göran; Hammarlund-Udenaes, Margareta

    2011-02-01

    Morphine has been predicted to show nonlinear blood-brain barrier transport at lower concentrations. In this study, we investigated the possibility of separating active influx of morphine from its efflux by using very low morphine concentrations and compared accelerator mass spectrometry (AMS) with liquid chromatography-tandem mass spectrometry (LC-MS/MS) as a method for analyzing microdialysis samples. A 10-min bolus infusion of morphine, followed by a constant-rate infusion, was given to male rats (n = 6) to achieve high (250 ng/ml), medium (50 ng/ml), and low (10 ng/ml) steady-state plasma concentrations. An additional rat received infusions to achieve low (10 ng/ml), very low (2 ng/ml), and ultralow (0.4 ng/ml) concentrations. Unbound morphine concentrations from brain extracellular fluid and blood were sampled by microdialysis and analyzed by LC-MS/MS and AMS. The average partition coefficient for unbound drug (K(p,uu)) values for the low and medium steady-state levels were 0.22 ± 0.08 and 0.21 ± 0.05, respectively, when measured by AMS [not significant (NS); p = 0.5]. For the medium and high steady-state levels, K(p,uu) values were 0.24 ± 0.05 and 0.26 ± 0.05, respectively, when measured by LC-MS/MS (NS; p = 0.2). For the low, very low, and ultralow steady-state levels, K(p,uu) values were 0.16 ± 0.01, 0.16 ± 0.02, and 0.18 ± 0.03, respectively, when measured by AMS. The medium-concentration K(p,uu) values were, on average, 16% lower when measured by AMS than by LC-MS/MS. There were no significant changes in K(p,uu) over a 625-fold concentration range (0.4-250 ng/ml). It was not possible to separate active uptake transport from active efflux using these low concentrations. The two analytical methods provided indistinguishable results for plasma concentrations but differed by up to 38% for microdialysis samples; however, this difference did not affect our conclusions.

  3. Analysis of aromatic hydrocarbons in petroleum fractions using gas chromatography, mass spectrometry and mass fragmentrography

    Energy Technology Data Exchange (ETDEWEB)

    Kubelka, V.

    1980-01-01

    Mass spectrometry in combination with gas chrom. used to analyze hydrocarbon mixtures results in qualit. and semi-quant. data regarding composition of the analyzed mixture. Use of mass fragmentrography during chromatographic separation will allow simultaneous recording of changes in intensity of characteristic ions and thus determine the retention index, for this substance. Combining mass spectre and retention index, it is possible to identify the given subst. or limit the number of possible combinations.

  4. Application of Pyrolysis Gas Chromatography/Mass Spectrometry in Lacquer Research: A Review

    Directory of Open Access Journals (Sweden)

    Xiao-Ming Ma

    2014-01-01

    Full Text Available Examination of thermal degradation of natural and synthetic lacquer films by pyrolysis-gas chromatography with mass spectrometry (Py-GC/MS is reviewed. Due to the instantaneous heating decomposition, side reactions of internal or intermediate samples hardly occur, and the pyrolysis products can be retrieved without any change. Py-GC/MS has been used to analyze the composition of insoluble polymers and investigate degradation of resin materials. Lacquer film is a cross-linked polymer that is insoluble in any solvent. The aim of this review is to describe the application of Py-GC/MS to the analysis of lacquer, including natural lacquer saps, synthetic lacquer derivatives, and their films. After analyzing the chemical structures of the specific pyrolysis products by mass spectrometry, the lacquer tree species and growing region can be determined. These results have great significance for the protection and restoration of lacquer-coated cultural treasures.

  5. Development of High Performance Liquid Chromatography and Mass Spectrometry:a Key Engine of TCM Modernization

    Institute of Scientific and Technical Information of China (English)

    Zheng-Xiang Zhang; Xue Qiao; Min Ye; Man-Yu Zhang; Yue Song; Tao Bo

    2015-01-01

    Traditional Chinese Medicine (TCM) has been popular for thousand years in prevention and treatment of chronic diseases synergistically with Western medicine while producing mild healing effects and lower side effects. Although many TCMs have been proven effective by modern pharmacological studies and clinical trials, their bioactive constituents and the remedial mechanisms are still not well understood. Researchers have made great efforts to explore the real theory of TCM for many years with different strategies. Development of high performance liquid chromatography (HPLC) and mass spectrometry within recent decade can provide scientists with robust technologies for disclosing the mysterious mask of TCM. In this paper, important innovations of HPLC and mass spectrometry are reviewed in the application of TCM analysis from single compound identification to metabolomic strategy.

  6. Recent advances of liquid chromatography-(tandem) mass spectrometry in clinical and forensic toxicology - An update.

    Science.gov (United States)

    Remane, Daniela; Wissenbach, Dirk K; Peters, Frank T

    2016-09-01

    Liquid chromatography (LC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) is a well-established and widely used technique in clinical and forensic toxicology as well as doping control especially for quantitative analysis. In recent years, many applications for so-called multi-target screening and/or quantification of drugs, poisons, and or their metabolites in biological matrices have been developed. Such methods have proven particularly useful for analysis of so-called new psychoactive substances that have appeared on recreational drug markets throughout the world. Moreover, the evolvement of high resolution MS techniques and the development of data-independent detection modes have opened new possibilities for applications of LC-(MS/MS) in systematic toxicological screening analysis in the so called general unknown setting. The present paper will provide an overview and discuss these recent developments focusing on the literature published after 2010.

  7. Determination of albendazole sulfoxide in human plasma by using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Saraner, Nihal; Özkan, Güler Yağmur; Güney, Berrak; Alkan, Erkin; Burul-Bozkurt, Nihan; Sağlam, Onursal; Fikirdeşici, Ezgi; Yıldırım, Mevlüt

    2016-06-01

    A rapid, simple and sensitive method was developed and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for determination of albendazole sulfoxide (ABZOX) in human plasma. The plasma samples were extracted by protein precipitation using albendazole sulfoxide-d3 as internal standard (IS). The chromatographic separation was performed on Waters Xbridge C18Column (100×4.6mm, 3.5μm) with a mobile phase consisting of ammonia solution, water and methanol at a flow rate of 0.70mL/min. ABZOX was detected and identified by mass spectrometry with electrospray ionization (ESI) in positive ion and multiple-reaction monitoring (MRM) mode. The method was linear in the range of 3-1500ng/mL for ABZOX. This method was successfully applied to the bioequivalence study in human plasma samples.

  8. Analyzing salvia divinorum and its active ingredient salvinorin a utilizing thin layer chromatography and gas chromatography/mass spectrometry.

    Science.gov (United States)

    Jermain, John D; Evans, Hiram K

    2009-05-01

    In recent years, Salvia divinorum has become a major focus by state legislatures throughout the United States looking to prohibit the sale of the psychoactive plant. After researching testing procedures presented in the literature and those employed by crime laboratories throughout the country, it was decided that thin layer chromatography (TLC) and gas chromatography/mass spectrometry (GC/MS) were the methods to use to analyze plant material for salvinorin A. With TLC, salvinorin A was detected from extracted plant material and was easily distinguishable from 13 other Salvia species as well as Cannabis sativa L. (marijuana). When using GC/MS, salvinorin A was best extracted from plant material with chloroform at ambient temperature when using a nonpolar solvent and acetone at ambient temperature when using a polar solvent. By utilizing these techniques, criminalists are now able to confirm the presence of salvinorin A in a submitted plant material suspected to be Salvia divinorum.

  9. Determination of polar organophosphorus pesticides in vegetables and fruits using liquid chromatography with tandem mass spectrometry: Selection of extraction solvent

    NARCIS (Netherlands)

    Mol, H.G.J.; Dam, R.C.J. van; Steijger, O.M.

    2003-01-01

    A method based on liquid chromatography (LC)-mass spectrometry (MS)/MS was developed for sensitive determination of a number of less gas chromatography (GC)-amenable organophosphorus pesticides (OPs; acephate, methamidophos, monocrotophos, omethoate, oxydemeton-methyl and vamidothion) in cabbage and

  10. Determination of 4-Chloroindole-3-Acetic Acid Methyl Ester in Lathyrus Vicia and Pisum by Gas Chromatography - Mass Spectrometry

    DEFF Research Database (Denmark)

    Engvild, Kjeld Christensen; Egsgaard, Helge; Larsen, Elfinn

    1980-01-01

    4-Chloroindole-3-acetic acid methyl ester was identified unequivocally in Lathyrus latifolius L., Vicia faba L. and Pisum sativum L. by thin layer chromatography, gas chromatography and mass spectrometry. The gas chromatographic system was able to separate underivatized chloroindole-3-acetic acid...... methyl ester isomers. The quantitative determination of 4-chloroindole-3-acetic acid methyl ester in immature seeds of these three species was performed by gas chromatographymass spectrometry using deuterium labelled 4-chloro-indole-3-acetic acid methyl ester as an internal standard. P. sativum...

  11. Heparin stability by determining unsubstituted amino groups using hydrophilic interaction chromatography mass spectrometry.

    Science.gov (United States)

    Fu, Li; Li, Lingyun; Cai, Chao; Li, Guoyun; Zhang, Fuming; Linhardt, Robert J

    2014-09-15

    The thermal instability of the anticoagulant heparin is associated, in part, with the solvolytic loss of N-sulfo groups. This study describes a new method to assess the increased content of unsubstituted amino groups present in thermally stressed and autoclave-sterilized heparin formulations. N-Acetylation of heparin samples with acetic anhydride-d6 is followed by exhaustive heparinase treatment and disaccharide analysis by hydrophilic interaction chromatography mass spectrometry (HILIC-MS). The introduction of a stable isotopic label provides a sensitive probe for the detection and localization of the lost N-sulfo groups, potentially providing valuable insights into the degradation mechanism and the reasons for anticoagulant potency loss.

  12. Screening of Brazilian fruit aromas using solid-phase microextraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Augusto, F; Valente, A L; dos Santos Tada, E; Rivellino, S R

    2000-03-17

    Manual headspace solid-phase microextraction (SPME) coupled to gas chromatography-mass spectrometry (GC-MS) was used for the qualitative analysis of the aromas of four native Brazilian fruits: cupuassu (Theobroma grandiflorum, Spreng.), cajá (Spondias lutea. L.), siriguela (Spondias purpurea, L.) and graviola (Anona reticulata, L). Industrialized pulps of these fruits were used as samples, and extractions with SPME fibers coated with polydimethylsiloxane, polyacrylate, Carbowax and Carboxen were carried out. The analytes identified included several alcohols, esters, carbonyl compounds and terpernoids. The highest amounts extracted, evaluated from the sum of peak areas, were achieved using the Carboxen fiber.

  13. Determination of ketone bodies in blood by headspace gas chromatography-mass spectrometry

    DEFF Research Database (Denmark)

    Holm, Karen Marie Dollerup; Linnet, Kristian; Rasmussen, Brian Schou

    2010-01-01

    A gas chromatography-mass spectrometry (GC-MS) method for determination of ketone bodies (ß-hydroxybutyrate, acetone, and acetoacetate) in blood is presented. The method is based on enzymatic oxidation of D-ß-hydroxybutyrate to acetoacetate, followed by decarboxylation to acetone, which...... was quantified by the use of headspace GC-MS using acetone-(13)C(3) as an internal standard. The developed method was found to have intra- and total interday relative standard deviations acetone+acetoacetate levels (~25 to 8300 µM) and D-ß-hydroxybutyrate levels (~30 to 16500 µM). Recovery values varied...

  14. Analysis of the citric acid cycle intermediates using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Kombu, Rajan S; Brunengraber, Henri; Puchowicz, Michelle A

    2011-01-01

    Researchers view analysis of the citric acid cycle (CAC) intermediates as a metabolomic approach to identifying unexpected correlations between apparently related and unrelated pathways of metabolism. Relationships of the CAC intermediates, as measured by their concentrations and relative ratios, offer useful information to understanding interrelationships between the CAC and metabolic pathways under various physiological and pathological conditions. This chapter presents a relatively simple method that is sensitive for simultaneously measuring concentrations of CAC intermediates (relative and absolute) and other related intermediates of energy metabolism using gas chromatography-mass spectrometry.

  15. Determination of cocaine in brazilian paper currency by capillary gas chromatography/mass spectrometry

    Directory of Open Access Journals (Sweden)

    Enrico Di Donato

    2007-01-01

    Full Text Available The presence of illicit drugs such as cocaine and marijuana in US paper currency is very well demonstrated. However, there is no published study describing the presence of cocaine and/or other illicit drugs in Brazilian paper currency. In this study, Brazilian banknotes were collected from nine cities, extracted and analyzed by capillary gas chromatography/mass spectrometry, in order to investigate the presence of cocaine. Bills were extracted with deionized water followed by ethyl acetate. Results showed that 93% of the bills presented cocaine in a concentration range of 2.38-275.10 µg/bill.

  16. Identification of a flunixin metabolite in camel by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Wasfi, I A; Hadi, A A; Alkatheeri, N A; Barezaiq, I M; ElGhazali, M; Boni, N S; Zorob, O

    1998-05-29

    A flunixin metabolite, a hydroxylated product, has been identified in camel urine and plasma samples using gas chromatography-mass spectrometry (GC-MS) and GC-MS-MS in the electron impact and chemical ionization modes. Its major fragmentation pattern has been verified by GC-MS-MS in daughter ion and parent ion scan modes. The method could detect flunixin and its metabolite in camel urine after a single intravenous dose of 2.2 mg of flunixin/kg body weight for 96 and 48 h, respectively, which increases the reliability of antidoping control analysis.

  17. Analysis of macrolide antibiotics, using liquid chromatography-mass spectrometry, in food, biological and environmental matrices.

    Science.gov (United States)

    Wang, Jian

    2009-01-01

    Macrolides are a group of antibiotics that have been widely used in human medical and veterinary practices. Analysis of macrolides and related compounds in food, biological, and environmental matrices continue to be the focus of scientists for the reasons of food safety, pharmacokinetic studies, and environmental concerns. This article presents an overview on the primary biological properties of macrolides and their associated analytical issues, including extraction, liquid chromatography-mass spectrometry (LC-MS), method validation, and measurement uncertainty. The main techniques that have been used to extract macrolides from various matrices are solid-phase extraction and liquid-liquid extraction. Conventional liquid chromatography (LC) with C18 columns plays a dominant role for the determination of macrolides, whereas ultra-performance liquid chromatography (UPLC) along with sub-2 microm particle C18 columns reduces run time and improves sensitivity. Mass spectrometry (MS), serving as a universal detection technique, has replaced ultraviolet (UV), fluorometric, and electrochemical detection for multi-macrolide analysis. The triple-quadrupole (QqQ), quadrupole ion trap (QIT), triple-quadrupole linear ion trap, time-of-flight (TOF), and quadrupole time-of-flight (QqTOF) mass spectrometers are current choices for the determination of macrolides, including quantification, confirmation, identification of their degradation products or metabolites, and structural elucidation. LC or UPLC coupled to a triple-quadrupole mass spectrometer operated in the multiple-reaction monitoring (MRM) mode (LC/MS/MS) is the first choice for quantification. UPLC-TOF or UPLC-QqTOF has been recognized as an emerging technique for accurate mass measurement and unequivocal identification of macrolides and their related compounds.

  18. Comparison of gas chromatography-mass spectrometry and gas chromatography-tandem mass spectrometry with electron ionization for determination of N-nitrosamines in environmental water.

    Science.gov (United States)

    Chen, Wenwen; Li, Xiaoshui; Huang, Huanfang; Zhu, Xuetao; Jiang, Xiaoyu; Zhang, Yuan; Cen, Kuang; Zhao, Lunshan; Liu, Xiuli; Qi, Shihua

    2017-02-01

    N-nitrosamines are trace organic contaminants of environmental concern when present in groundwater and river water due to their potent carcinogenicity. Therefore, N-nitrosamine analysis is increasingly in demand. Gas chromatography-mass spectrometry (GC-MS) and GC-tandem mass spectrometry (GC-MS/MS), both with electron ionization (EI), were compared for analysis of nine N-nitrosamines extracted from environmental water matrices. A total of 20 fishpond water, river water, and groundwater samples from Sihui and Shunde, China were collected for a survey of N-nitrosamine concentrations in real water samples. Various solid-phase extraction (SPE) conditions and GC conditions were first examined for the pre-concentration and separation steps. The analysis of N-nitrosamines in environmental waters demonstrated that their quantification with GC-MS poses a challenge due to the occurrence of co-eluting interferences. Conversely, the use of GC-MS/MS increased selectivity because of the fragmentation generated from precursor ions in the 'multiple reaction monitoring' (MRM) mode, which is expected to extract target analytes from the environmental water matrix. Thus, the high performance of GC-MS/MS with EI was used to quantify nine N-nitrosamines in environmental waters with detection limits of 1.1-3.1 ng L(-1). N-nitrosodimethylamine (NDMA) concentrations were in the range of N.D. to 258 ng L(-1). Furthermore, other N-nitrosamines, except N-nitrosomethylethylamine (NMEA), N-nitroso-di-n-propylamine (NDPA) and N-nitrosopiperidine (NPIP), were also detected. Our findings suggest that GC-MS/MS with EI would be widely applicable in identifying N-nitrosamines in environmental waters and can be used for routine monitoring of these chemicals.

  19. Determination of rare earth elements in high purity rare earth oxides by liquid chromatography, thermionic mass spectrometry and combined liquid chromatography/thermionic mass spectrometry

    Science.gov (United States)

    Stijfhoorn, D. E.; Stray, H.; Hjelmseth, H.

    1993-03-01

    A high-performance liquid Chromatographie (HPLC) method for the determination of rare earth elements in rocks has been modified and used for the determination of rare earth elements (REE) in high purity rare earth oxides. The detection limit was 1-1.5 ng or 2-3 mg/kg when a solution corresponding to 0.5 mg of the rare earth oxide was injected. The REE determination was also carried out by adding a mixture of selected REE isotopes to the sample and analysing the collected HPLC-fractions by mass spectrometry (MS) using a thermionic source. Since the matrix element was not collected, interference from this element during the mass spectrometric analysis was avoided. Detection limits as low as 0.5 mg/kg could then be obtained. Detection limits as low as 0.05 mg/kg were possible by MS without HPLC-pre-separation, but this approach could only be used for those elements that were not affected by the matrix. Commercial samples of high purity Nd 2O 3, Gd 2O 3 and Dy 2O 3 were analysed in this study, and a comparison of results obtained by HPLC, combined HPLC/MS and direct MS are presented.

  20. Analyses of acute kidney injury biomarkers by ultra-high performance liquid chromatography with mass spectrometry.

    Science.gov (United States)

    Al Za'abi, Mohammed; Ali, Badreldin H; ALOthman, Zeid A; Ali, Imran

    2016-01-01

    The newly developed acute kidney injury biomarkers are very important for the early and timely detection of kidney diseases. This review contains details of the analyses of several acute kidney injury biomarkers using ultra-high performance liquid chromatography-mass spectrometry in urine and plasma samples. In this review we attempt to discuss some aspects of the types of the biomarkers, patents, sample preparation, and the analyses. Besides, efforts were also made to discuss the possible uses of superficially porous (core-shell) columns in traditional and inexpensive high-performance liquid chromatography instruments. Additionally, the challenges and the future prospects are also highlighted. The present review will be useful for the academicians, scientists, and clinicians for the early detection of acute kidney injury biomarkers.

  1. Use, history, and liquid chromatography/mass spectrometry chemical analysis of Aconitum

    Directory of Open Access Journals (Sweden)

    Mohamed El-Shazly

    2016-01-01

    Full Text Available Aconitum and its products have been used in Asia for centuries to treat various ailments, including arthritis, gout, cancer, and inflammation. In general, their preparations and dispensing have been restricted to qualified folk medicine healers due to their low safety index and reported toxicity. In the past few decades, official guidelines have been introduced in Asian pharmacopeias to control Aconitum herbal products. However, these guidelines were based on primitive analytical techniques for the determination of the whole Aconitum alkaloids and were unable to distinguish between toxic and nontoxic components. Recent advances in analytical techniques, especially high performance liquid chromatography (HPLC and electrophoresis coupled with highly sensitive detectors, allowed rapid and accurate determination of Aconitum secondary metabolites. Reports focusing on liquid chromatography/mass spectrometry analysis of Aconitum and its herbal products are discussed in the current review. This review can be used by the health regulatory authorities for updating pharmacopeial guidelines of Aconitum and its herbal products.

  2. Detection of ergot (Claviceps purpurea) in a dairy feed component by gas chromatography and mass spectrometry.

    Science.gov (United States)

    Mantle, P G

    1996-11-01

    A dairy feed that contained barley malt screenings caused hyperthermia in dairy cattle. The feed was suspected of containing ergot and was subsequently analyzed to determine the ricinoleate component, a special and prominent feature of oil-rich ergot tissue. Triglyceride oil was extracted by organic solvents from the dairy feed, and the oil was saponified to release fatty acids. Ricinoleate, as a methyl ester, was selectively resolved from other fatty acids by silica gel chromatography and was analyzed by capillary gas chromatography coupled with chemical ionization mass spectrometry, which demonstrated the presence of the methyl ricinoleate molecule and proved that the feed contained ergot. The methodology may be refined to monitor for ergot in powdered dairy feed more routinely.

  3. Development and application of liquid chromatography coupled to isotope ratio mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Lijun

    2014-02-19

    Stable isotope analysis has found widespread applications in various disciplines such as archaeology, geochemistry, biology, food authenticity, and forensic science. Coupling chromatography to isotope ratio mass spectrometry for compound-specific isotope analysis (CSIA) is a trend, as it provides several advantages over bulk isotope analysis, e.g., relatively simple sample preparation, the ability to measure individual compounds in a complex mixture in one run, and the reduced sample size required for precise isotope analysis. Gas chromatography coupled to isotope ratio mass spectrometry (GC/IRMS) has been well-established for compound-specific isotope analysis of volatile organic compounds within the last two decades. However, an interface combining liquid chromatography with isotope ratio mass spectrometry (LC/IRMS) was not commercially available until 2004. The current design of the interface requires using a carbon-free eluent in chromatographic separation. This requirement limits the application of the most frequently used reversed-phase liquid chromatography in CSIA, because the elution strength of water at room temperature is too low to serve as mobile phase in reversed-phase separations. In order to increase the elution strength of water, we propose using high temperature water for chromatographic elution. The polarity of water decreases with an increase of temperature, yielding increased elution strength in reversed-phase columns. Therefore, high temperature water can be used as eluent instead of organic solvent for combining reversed-phase liquid chromatography with isotope ratio mass spectrometry (RPLC/IRMS). Additionally, temperature gradients can replace organic solvent gradients to increase chromatographic resolution. This is very important for LC/IRMS analysis, as precise isotope analysis requires baseline separation of analytes. In this thesis, high-temperature reversed-phase liquid chromatography was coupled to, and for the first time carefully

  4. Quantitative Thin-Layer Chromatography/Mass Spectrometry Analysis of Caffeine Using a Surface Sampling Probe Electrospray Ionization Tandem Mass Spectrometry System

    Energy Technology Data Exchange (ETDEWEB)

    Ford, Michael J [ORNL; Deibel, Michael A. [Earlham College; Tomkins, Bruce A [ORNL; Van Berkel, Gary J [ORNL

    2005-01-01

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 {mu}m/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 {mu}L) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by 8% or more) than the literature values.

  5. Degradation study of enniatins by liquid chromatography-triple quadrupole linear ion trap mass spectrometry.

    Science.gov (United States)

    Serrano, A B; Meca, G; Font, G; Ferrer, E

    2013-12-15

    Enniatins A, A1, B and B1 (ENs) are mycotoxins produced by Fusarium spp. and are normal contaminants of cereals and derivate products. In this study, the stability of ENs was evaluated during food processing by simulation of pasta cooking. Thermal treatments at different incubation times (5, 10 and 15 min) and different pH (4, 7 and 10) were applied in an aqueous system and pasta resembling system (PRS). The concentrations of the targeted mycotoxins were determined using liquid chromatography coupled to tandem mass spectrometry. High percentages of ENs reduction (81-100%) were evidenced in the PRS after the treatments at 5, 10 and 15 min of incubation. In contrast to the PRS, an important reduction of the ENs was obtained in the aqueous system after 15 min of incubation (82-100%). In general, no significant differences were observed between acid, neutral and basic solutions. Finally, several ENs degradation products were identified using the technique of liquid chromatography-triple quadrupole linear ion trap mass spectrometry.

  6. Recent progress in polar metabolite quantification in plants using liquid chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Zhiqian Liu; Simone Rochfort

    2014-01-01

    Metabolite analysis or metabolomics is an impor-tant component of systems biology in the post-genomic era. Although separate liquid chromatography (LC) methods for quantification of the major classes of polar metabolites of plants have been available for decades, a single method that enables simultaneous determination of hundreds of polar metabolites is possible only with gas chromatography-mass spectrometry (GC-MS) techniques. The rapid expansion of new LC stationary phases in the market and the ready access of mass spectrometry in many laboratories provides an excellent opportunity for developing LC-MS based methods for multi-target quantification of polar metabolites. Although various LC-MS methods have been developed over the last 10 years with the aim to quantify one or more classes of polar compounds in different matrices, currently there is no consensus LC-MS method that is widely used in plant metabolomics studies. The most promising methods applicable to plant metabolite analysis wil be reviewed in this paper and the major problems encountered highlighted. The aim of this review is to provide plant scientists, with limited to moderate experience in analytical chemistry, with up-to-date and simplified information regarding the current status of polar metabolite analysis using LC-MS techniques.

  7. [Determination of residual glycol ethers in leather and leather products by gas chromatography/mass spectrometry].

    Science.gov (United States)

    Wang, Ghengyun; Zhang, Weiya; Li, Lixia; Shen, Yalei; Lin, Junfeng; Xie, Tangtang; Chu, Naiqing

    2014-08-01

    An effective method was established for the simultaneous determination of residual glycol ethers in leather and leather products by gas chromatography/mass spectrometry. Glycol ethers in leather and leather products were ultrasonically extracted at 45 °C, using ethyl acetate as the extraction solvent. The extracts were purified by solid phase extraction (SPE) columns, and then analyzed by gas chromatography/mass spectrometry in selected ion monitoring mode. The content of each analyte was calibrated by external standard method. The limit of detection of ethylene glycol ethyl ether (EGEE) was 0. 10 mg/kg under the condition of signal to noise (S/N) of 3 and the limits of the other 11 glycol ethers were all less than 0.05 mg/kg. The spiked recoveries varied from 81. 2% to 95. 5% at three different spiked levels with the relative standard deviations (RSDs) ranged from 1.4% to 6. 6%. The proposed method is simple, rapid and accurate, with the limits of detection much less than the requirements of the Regulation Concerning Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) of European Union. It is applicable to the determination of residual glycol ethers in leather and leather products, and provides a reference for the relevant testing standards.

  8. Determination of parabens in serum by liquid chromatography-tandem mass spectrometry: Correlation with lipstick use.

    Science.gov (United States)

    Tahan, Gabriella Padovani; Santos, Nayara de Kássia Souza; Albuquerque, Ana Carolina; Martins, Isarita

    2016-08-01

    Parabens are the most widely used preservative and are considered to be relatively safe compounds. However, studies have demonstrated that they may have estrogenic activity, and there is ongoing debate regarding the safety and potential cancer risk of using products containing these compounds. In the present work, liquid chromatography-tandem mass spectrometry was applied to determine methylparaben and propylparaben concentrations in serum, and the results were correlated with lipstick application. Samples were analyzed using liquid-liquid extraction, followed by liquid chromatography-tandem mass spectrometry. The validation results demonstrated the linearity of the method over a range of 1-20 ng/mL, in addition to the method's precision and accuracy. A statistically significant difference was demonstrated between serum parabens in women who used lipstick containing these substances compared with those not using this cosmetic (p = 0.0005 and 0.0016, respectively), and a strong association was observed between serum parabens and lipstick use (Spearman correlation = 0.7202).

  9. Determination of bromate in drinking water by ultraperformance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Alsohaimi, Ibrahim Hotan; Alothman, Zeid Abdullah; Khan, Mohammad Rizwan; Abdalla, Mohammad Abulhassan; Busquets, Rosa; Alomary, Ahmad Khodran

    2012-10-01

    Bromate is a byproduct formed as a result of disinfection of bromide-containing source water with ozone or hypochlorite. The International Agency for Research on Cancer has recognized bromate as a possible human carcinogen, thus it is essential to determine in drinking water. Present work highlights a development of sensitive and fast analytical method for bromate determination in drinking water by using ultraperformance liquid chromatography-tandem mass spectrometry. The quality parameters of the developed method were established, obtaining very low limit of detection (0.01 ng/mL), repeatability and reproducibility have been found to be less than 3% in terms of relative standard deviation when analyzing a bromate standard at 0.05 μg/mL with 0.4 min analysis time. Developed method was applied for the analysis of metropolitan and bottled water from Saudi Arabia; 22 samples have been analyzed. Bromate was detected in the metropolitan water samples (from desalinization source) at concentrations ranging between 3.43 and 75.04 ng/mL and in the bottled water samples at concentrations ranging between 2.07 and 21.90 ng/mL. Moreover, in comparison to established analytical methods such as liquid chromatography-tandem mass spectrometry, the proposed method was found to be very sensitive, selective and rapid for the routine analysis of bromate at low level in drinking water.

  10. Quantitation of acrylamide in food products by liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Eberhart, B Loye; Ewald, Deborah K; Sanders, Robert A; Tallmadge, Daniel H; Zyzak, David V; Strothers, Melissa A

    2005-01-01

    A simple and inexpensive liquid chromatography/mass spectrometry (LC/MS) method was developed for the quantitation of acrylamide in various food products. The method involved spiking the isotope-substituted internal standard (1-C13 acrylamide) onto 6.00 g of the food product, adding 40 mL distilled/deionized water, and heating at 65 degrees C for 30 min. Afterwards, 10 mL ethylene dichloride was added and the mixture was homogenized for 30 s and centrifuged at 2700 x g for 30 min, and then 8 g supernatant was extracted with 10, 5, and 5 mL portions of ethyl acetate. The extracts were combined, dried with sodium sulfate, and concentrated to 100-200 microL. Acrylamide was determined by analysis of the final extract on a single quadrupole, bench-top mass spectrometer with electrospray ionization, using a 2 mm id C18 column and monitoring m/z = 72 (acrylamide) and m/z = 73 (internal standard). For difficult food matrixes, such as coffee and cocoa, a solid-phase extraction cleanup step was incorporated to improve both chromatography and column lifetime. The method had a limit of quantitation of 10 ppb, and coefficients of determination (r2) for calibration curves were typically better than 0.998. Acceptable spike recovery results were achieved in 11 different food matrixes. Precision in potato chip analyses was 5-8% (relative standard deviation). This method provides an LC/MS alternative to the current LC/MS/MS methods and derivatization gas chromatography/mass spectrometry methods, and is applicable to difficult food products such as coffee, cocoa, and high-salt foods.

  11. Sheath liquid effects in capillary high-performance liquid chromatography-electrospray mass spectrometry of oligonucleotides.

    Science.gov (United States)

    Huber, C G; Krajete, A

    2000-02-18

    Fused-silica capillary columns of 200 microm inner diameter were packed with micropellicular, octadecylated, 2.3 microm poly(styrene-divinylbenzene) particles and applied to the separation of oligonucleotides by ion-pair reversed-phase high-performance liquid chromatography. Oligonucleotides were eluted at 50 degrees C with gradients of 3-13% acetonitrile in 50 mM triethylammonium bicarbonate. Addition of sheath liquid to the column effluent allowed the detection of oligonucleotides by electrospray ionization mass spectrometry using full-scan data acquisition with a detectability comparable to that obtained with UV detection. The signal-to-noise ratios with different sheath liquids increased in the order isopropanolmass spectra mainly because of increased background noise. Only a few charge states were observed in the mass spectra of oligonucleotides because of charge state reduction due to the presence of carbonic acid in the eluent. With triethylammonium hydrogencarbonate as chromatographic eluent and acetonitrile as sheath liquid, very few cation adducts of oligonucleotides were observed in the mass spectra. However, the presence of small amounts of monopotassium adducts enabled the calculation of the charge state of multiply charged ions. With acetonitrile as sheath liquid, 710 amol of a 16-mer oligonucleotide were detected using selected ion monitoring data acquisition with a signal-to-noise ratio of 3:1. Finally, capillary ion-pair reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry was

  12. Online Hydrophobic Interaction Chromatography-Mass Spectrometry for Top-Down Proteomics.

    Science.gov (United States)

    Chen, Bifan; Peng, Ying; Valeja, Santosh G; Xiu, Lichen; Alpert, Andrew J; Ge, Ying

    2016-02-01

    Recent progress in top-down proteomics has led to a demand for mass spectrometry (MS)-compatible chromatography techniques to separate intact proteins using volatile mobile phases. Conventional hydrophobic interaction chromatography (HIC) provides high-resolution separation of proteins under nondenaturing conditions but requires high concentrations of nonvolatile salts. Herein, we introduce a series of more-hydrophobic HIC materials that can retain proteins using MS-compatible concentrations of ammonium acetate. The new HIC materials appear to function as a hybrid form of conventional HIC and reverse phase chromatography. The function of the salt seems to be preserving protein structure rather than promoting retention. Online HIC-MS is feasible for both qualitative and quantitative analysis. This is demonstrated with standard proteins and a complex cell lysate. The mass spectra of proteins from the online HIC-MS exhibit low charge-state distributions, consistent with those commonly observed in native MS. Furthermore, HIC-MS can chromatographically separate proteoforms differing by minor modifications. Hence, this new HIC-MS combination is promising for top-down proteomics.

  13. Hyphenated and comprehensive liquid chromatography × gas chromatography-mass spectrometry for the identification of Mycobacterium tuberculosis.

    Science.gov (United States)

    Mourão, Marta P B; Denekamp, Ilse; Kuijper, Sjoukje; Kolk, Arend H J; Janssen, Hans-Gerd

    2016-03-25

    Tuberculosis is one of the world's most emerging public health problems, particularly in developing countries. Chromatography based methods have been used to tackle this epidemic by focusing on biomarker detection. Unfortunately, interferences from lipids in the sputum matrix, particularly cholesterol, adversely affect the identification and detection of the marker compounds. The present contribution describes the serial combination of normal phase liquid chromatography (NPLC) with thermally assisted hydrolysis and methylation followed by gas chromatography-mass spectrometry (THM-GC-MS) to overcome the difficulties of biomarker evaluation. The in-series combination consists of an LC analysis where fractions are collected and then transferred to the THM-GC-MS system. This was either done with comprehensive coupling, transferring all the fractions, or with hyphenated interfacing, i.e. off-line multi heart-cutting, transferring only selected fractions. Owing to the high sensitivity and selectivity of LC as a sample pre-treatment method, and to the high specificity of the MS as a detector, this analytical approach, NPLC × THM-GC-MS, is extremely sensitive. The results obtained indicate that this analytical set-up is able to detect down to 1 × 10(3) mycobacteria/mL of Mycobacterium tuberculosis strain 124, spiked in blank sputum samples. It is a powerful analytical tool and also has great potential for full automation. If further studies demonstrate its usefulness when applied blind in real sputum specimens, this technique could compete with the current smear microscopy in the early diagnosis of tuberculosis.

  14. Determination of constituents of essential oil from Angelica sinensis by gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    WU Ming-jian; SUN Xian-jun; DAI Yuan-hui; GUO Fang-qiu; HUANG Lan-fang; LIANG Yi-zeng

    2005-01-01

    Gas chromatography-mass spectrometry (GC-MS) coupled with chemometric resolution upon two-dimensional data was employed to analyze the constituents of essential oils of Angelica sinensis. Constituents in essential oils of Angelica sinensis root were identified by GC-MS with the help of subwindow factor analysis (SFA) method resolving two-dimensional original data into mass spectra and chromatograms. 76 of 97 separated constituents in essential oil of Angelica sinensis root were identified and quantified, and they account for about 91.36% of the total content. The results show that ligustilide, butylene phthalide, 2-methoxy-4-vinylphenol, carvacrol, allo-ocimene,2,6,6-trimethylbicyclo-[3,1,1]hept-2-ene are the main constituents in essential oil of Angelica sinensis root.

  15. [Metabonomics study of lung cancer cells based on liquid l chromatography-mass spectrometry].

    Science.gov (United States)

    Yu, Xinwei; Wu, Qian; Lu, Wang; Wang, Yan; Ma, Xiaoqiong; Chen, Zhe; Yan, Chao

    2013-07-01

    The metabolic profiles of the polar metabolites and the non-polar metabolites in lung tumor cell lines H358, A549, HCC827, H1299, Calu-3, Calu-l, PC-9 and normal cell line MRC-5 were analyzed separately using high performance liquid chromatography-quadrupole time-of flight mass spectrometry (HPLC-Q-TOF/MS). Partial least square discriminant analysis ( PLS-DA) was used to process the metabolic data. The results showed that the metabolites of the lung cancer cell lines and normal cell line have significant differences. Further, 10 polar metabolites and 21 non-polar metabolites which had a significant contribution to classification were selected and preliminarily identified due to the accurate mass. Comparing with the normal cell line, the lung tumor cell lines present an abnormal metabolism in protein, fatty acid, and phospholipids. These results may provide important information for the early diagnosis of lung cancer.

  16. Electrospray liquid chromatography/mass spectrometry fingerprinting of Acanthophis (death adder) venoms: taxonomic and toxinological implications.

    Science.gov (United States)

    Fry, Bryan G; Wickramaratna, Janith C; Hodgson, Wayne C; Alewood, Paul F; Kini, R M; Ho, Hao; Wüster, Wolfgang

    2002-01-01

    Death adders (genus Acanthophis) are unique among elapid snakes in both morphology and venom composition. Despite this genus being among the most divergent of all elapids, the venom has been historically regarded as relatively quite simple. In this study, liquid chromatography/mass spectrometry (LC/MS) analysis has revealed a much greater diversity in venom composition, including the presence of molecules of novel molecular weights that may represent a new class of venom component. Furthermore, significant variation exists between species and populations, which allow for the LC/MS fingerprinting of each species. Mass profiling of Acanthophis venoms clearly demonstrates the effectiveness of this technique which underpins fundamental studies ranging from chemotaxonomy to drug design.

  17. First screening method for the simultaneous detection of seven allergens by liquid chromatography mass spectrometry.

    Science.gov (United States)

    Heick, J; Fischer, M; Pöpping, B

    2011-02-18

    The development of a multi-method for the detection of seven allergens based on liquid chromatography and triple-quadrupole tandem mass spectrometry in multiple reaction mode is described. It is based on extraction of the allergenic proteins from a food matrix, followed by enzymatic digestion with trypsin. The chosen marker peptides were implemented into one method that is capable of the simultaneous detection of milk, egg, soy, hazelnut, peanut, walnut and almond. This method has been used to detect all seven allergenic commodities from incurred reference bread material, which was baked according to a standard recipe from the baking industry. Detected concentrations ranged from 10 to 1000 μg/g, demonstrating that the mass spectrometric based method is a useful tool for allergen screening.

  18. Liquid chromatography-mass spectrometry coupling by the intermediary of a liquid micro chromatography-electro spray interface; Couplage chromatographie liquide-spectrometrie de masse par l`intermediaire d`une interface electrospray-microchromatographie liquide

    Energy Technology Data Exchange (ETDEWEB)

    Gillard Factor, C.

    1996-12-06

    The objective of this work is to realize a liquid chromatography- mass spectrometry coupling by the intermediary of an electro spray interface and the evaluation of performances of tis analytical tool to study pollutants in water, and more particularly pesticides whom maximum admissible concentration in a table water is 0.1{mu}g/l. This study has allowed to bring to the fore the interest of the ionization mode by electro spray in a LC/MS coupling to identify and quantify pesticides in the state of traces without treating the sample. Then, it was demonstrated the usefulness of this analytical tool to detect high molecular masses molecules. (N.C.)

  19. Detecting trace components in liquid chromatography/mass spectrometry data sets with two-dimensional wavelets

    Science.gov (United States)

    Compton, Duane C.; Snapp, Robert R.

    2007-09-01

    TWiGS (two-dimensional wavelet transform with generalized cross validation and soft thresholding) is a novel algorithm for denoising liquid chromatography-mass spectrometry (LC-MS) data for use in "shot-gun" proteomics. Proteomics, the study of all proteins in an organism, is an emerging field that has already proven successful for drug and disease discovery in humans. There are a number of constraints that limit the effectiveness of liquid chromatography-mass spectrometry (LC-MS) for shot-gun proteomics, where the chemical signals are typically weak, and data sets are computationally large. Most algorithms suffer greatly from a researcher driven bias, making the results irreproducible and unusable by other laboratories. We thus introduce a new algorithm, TWiGS, that removes electrical (additive white) and chemical noise from LC-MS data sets. TWiGS is developed to be a true two-dimensional algorithm, which operates in the time-frequency domain, and minimizes the amount of researcher bias. It is based on the traditional discrete wavelet transform (DWT), which allows for fast and reproducible analysis. The separable two-dimensional DWT decomposition is paired with generalized cross validation and soft thresholding. The Haar, Coiflet-6, Daubechie-4 and the number of decomposition levels are determined based on observed experimental results. Using a synthetic LC-MS data model, TWiGS accurately retains key characteristics of the peaks in both the time and m/z domain, and can detect peaks from noise of the same intensity. TWiGS is applied to angiotensin I and II samples run on a LC-ESI-TOF-MS (liquid-chromatography-electrospray-ionization) to demonstrate its utility for the detection of low-lying peaks obscured by noise.

  20. CREATININE DETERMINATION IN URINE BY LIQUID CHROMATOGRAPHY-ELECTROSPRAY IONIZATION-TANDEM MASS SPECTROMETRY METHOD.

    Science.gov (United States)

    Dereziński, Paweł; Klupczyńska, Agnieszka; Sawicki, Wojciech; Kokot, Zenon J

    2016-01-01

    Creatinine determination in urine is used to estimate the completeness of the 24-h urine collection, compensation for variable diuresis and as a preliminary step in protein profiling in urine. Despite the fact that a wide range of methods of measuring creatinine level in biofluids has been developed, many of them are adversely affected by interfering substances. A new liquid chromatography-tandem mass spectrometry method for creatinine determination in urine has been developed. Chromatographic separation was performed by applying C18 column and a gradient elution. Analyses were carried out on a triple quadrupole mass spectrometer equipped with an electrospray ion source. The developed method was fully validated according to the international guidelines. The quantification range of the method was 5-1500 ng/mL, which corresponds to 1-300 mg/dL in urine. Limit of detection and quantitation were 2 and 5 ng/mL, respectively. Additionally, the comparison of creatinine determination by newly developed method to the colorimetric method was performed. The method enables the determination of creatinine in urine samples with a minimal sample preparation, excellent sensitivity and prominent selectivity. Since mass spectrometry allows to measure a number of compounds simultaneously, a future perspective would be to incorporate the determination of other clinically important compounds excreted in urine.

  1. Liquid chromatography coupled to tandem mass spectrometry for the analysis of acrylamide in typical Spanish products.

    Science.gov (United States)

    Bermudo, E; Moyano, E; Puignou, L; Galceran, M T

    2008-07-15

    This paper describes the use of liquid chromatography coupled to tandem mass spectrometry for the determination of acrylamide in several typical foods produced and consumed in Spain. Christmas sweets, olives, traditionally made potato crisps, pastry products, sweet fritters ("churros") and one of Spain's most famous dishes, Spanish omelette, were selected. Using the mass spectra information provided by an ion trap analyzer in combination with the accurate mass measurements from time-of-flight (TOF) spectrometry a co-extractive interference present in some potato products was identified as valine. A porous graphitic carbon column, which enabled the co-extractive and acrylamide to be separated, and ion trap or triple quadrupole analyzers, depending on the acrylamide concentration, were used to determine this genotoxic compound in foodstuffs. The highest values were found in potato products, sweet fritters, Christmas sweets and pastry products, with values ranging between 70 and 2000 microg/g. Spanish omelette presented relatively low levels, similar to those obtained for dried fruits.

  2. Determination of Candesartan in Human Plasma with Liquid Chromatography - Tandem Mass Spectrometry.

    Science.gov (United States)

    Forjan, Vanja; Cvitkovič Maričič, Lea; Prosen, Helena; Brodnjak Vončina, Darinka

    2016-01-01

    A sensitive, specific and rapid liquid chromatography - tandem mass spectrometry method was developed and validated for the determination of candesartan in human plasma. Analyte was separated from endogenous components present in plasma by solid phase extraction. Chromatographic separation was performed on Gemini C18 analytical column using mobile phase acetonitrile - 5 mM ammonium formate pH 2 (90:10, v/v) at flow rate of 0.3 mL/min. For detection, tandem mass spectrometry in SRM mode with positive electrospray ionization was used. The mass transitions m/z 441.1 > 263.1 and 445.1 > 267.1 were used to determine candesartan by using candesartan-d4 as an internal standard. After development, the method was validated according to the requirements of EMA regulatory guidelines in the concentration range 1 - 400 ng/ml in human plasma. Limit of quantification (LLOQ) was 1 ng/ml. The developed and validated method proved to be very fast and reproducible and was therefore successfully implemented in pharmacokinetic and bioequivalence studies with large number of study samples.

  3. Analysis of the venom of the Sydney funnel-web spider, Atrax robustus using gas chromatography mass spectrometry.

    Science.gov (United States)

    Duffield, P H; Duffield, A M; Carroll, P R; Morgans, D

    1979-03-01

    Thirteen compounds have been identified using gas chromatography mass spectrometry in the venom of the Sydney funnel-web spider, Atrax robustus. The compounds were identified as their trimethylsilyl or pentafluoropropionate derivatives and were citric acid, lactic acid, phosphoric acid, glycerol, urea, glucose, gamma-aminobutyric acid, glycine, spermidine, spermine, tyramine and octopamine. Female venom contained trace quantities of 5-methyoxytryptamine which was not detected in male venom. Quantitative determination of tyramine and octopamine was achieved using chemical ionization (CH4) gas chromatography mass spectrometry and deuterated internal standards.

  4. Bioassay- and liquid chromatography/mass spectrometry-guided acetylcholinesterase inhibitors from Picriafel-terrae

    Directory of Open Access Journals (Sweden)

    Lu Wen

    2013-01-01

    Full Text Available Background: Picria fel-terrae is a traditional Chinese medicine. Materials and Methods: A new approach to the search for acetylcholinesterase (AChE inhibitors from Picria fel-terrae is presented. Results: Bioassay- and LC-MS-guided fractionation of the ethyl acetate extract was from traditional Chinese medicine P.fel-terrae. Following primary extraction, the ethyl acetate extracts fraction of P.fel-terrae showed strong AChE inhibitory activities. So the sample was separated using highperformance liquid chromatography (HPLC. The effluent was split towards two identical 96-well fraction collectors, and the presence of the biologically interesting portion and chromatographic fractions could be readily detected by analyzing selected ion chromatograms through an electrophoresis-electrospray ionization mass spectrometry (ESIMS system for accurate mass measurement. One 96-well plate was used for a bioassay (AChE-inhibitory assay and detected the bioactivity and position of the relevant peak in the chromatogram. The positive well in the second 96-well plate was used for identification by LC-(+ ESIMS. Conclusion: As abovementioned, the AChE inhibitory constituents from P.fel-terrae by LC-bioassay-ESIMS were rapid identified. Liquid chromatography/ mass spectrometry (LC-MS screening detected the presence of six active compounds, identified as picfeltarraenin IA (1, picfeltarraenin IB (2, picfeltarraenin IV (3, picfeltarraenin X (4, picfeltarraenin XI (5, and one unknown compound. The structures were further determined by 13C NMR. The six compounds expressed stronger AChE inhibition than the known AChE inhibitorTacrine. Above all, the value of this LC-bioassay-ESIMS methodology is highlighted by the finding and structure elucidation of the active constituents from many other structural families of natural products.

  5. On the utility of predictive chromatography to complement mass spectrometry based intact protein identification.

    Science.gov (United States)

    Pridatchenko, Marina L; Perlova, Tatyana Yu; Ben Hamidane, Hisham; Goloborodko, Anton A; Tarasova, Irina A; Gorshkov, Alexander V; Evreinov, Victor V; Tsybin, Yury O; Gorshkov, Mikhail V

    2012-03-01

    The amino acid sequence determines the individual protein three-dimensional structure and its functioning in an organism. Therefore, "reading" a protein sequence and determining its changes due to mutations or post-translational modifications is one of the objectives of proteomic experiments. The commonly utilized approach is gradient high-performance liquid chromatography (HPLC) in combination with tandem mass spectrometry. While serving as a way to simplify the protein mixture, the liquid chromatography may be an additional analytical tool providing complementary information about the protein structure. Previous attempts to develop "predictive" HPLC for large biomacromolecules were limited by empirically derived equations based purely on the adsorption mechanisms of the retention and applicable to relatively small polypeptide molecules. A mechanism of the large biomacromolecule retention in reversed-phase gradient HPLC was described recently in thermodynamics terms by the analytical model of liquid chromatography at critical conditions (BioLCCC). In this work, we applied the BioLCCC model to predict retention of the intact proteins as well as their large proteolytic peptides separated under different HPLC conditions. The specific aim of these proof-of-principle studies was to demonstrate the feasibility of using "predictive" HPLC as a complementary tool to support the analysis of identified intact proteins in top-down, middle-down, and/or targeted selected reaction monitoring (SRM)-based proteomic experiments.

  6. Thin layer chromatography coupled to paper spray ionization mass spectrometry for cocaine and its adulterants analysis.

    Science.gov (United States)

    De Carvalho, Thays C; Tosato, Flavia; Souza, Lindamara M; Santos, Heloa; Merlo, Bianca B; Ortiz, Rafael S; Rodrigues, Rayza R T; Filgueiras, Paulo R; França, Hildegardo S; Augusti, Rodinei; Romão, Wanderson; Vaz, Boniek G

    2016-05-01

    Thin layer chromatography (TLC) is a simple and inexpensive type of chromatography that is extensively used in forensic laboratories for drugs of abuse analysis. In this work, TLC is optimized to analyze cocaine and its adulterants (caffeine, benzocaine, lidocaine and phenacetin) in which the sensitivity (visual determination of LOD from 0.5 to 14mgmL(-1)) and the selectivity (from the study of three different eluents: CHCl3:CH3OH:HCOOHglacial (75:20:5v%), (C2H5)2O:CHCl3 (50:50v%) and CH3OH:NH4OH (100:1.5v%)) were evaluated. Aiming to improve these figures of merit, the TLC spots were identified and quantified (linearity with R(2)>0.98) by the paper spray ionization mass spectrometry (PS-MS), reaching now lower LOD values (>1.0μgmL(-1)). The method developed in this work open up perspective of enhancing the reliability of traditional and routine TLC analysis employed in the criminal expertise units. Higher sensitivity, selectivity and rapidity can be provided in forensic reports, besides the possibility of quantitative analysis. Due to the great simplicity, the PS(+)-MS technique can also be coupled directly to other separation techniques such as the paper chromatography and can still be used in analyses of LSD blotter, documents and synthetic drugs.

  7. Methods of analysis-Determination of pesticides in sediment using gas chromatography/mass spectrometry

    Science.gov (United States)

    Hladik, Michelle L.; McWayne, Megan M.

    2012-01-01

    A method for the determination of 119 pesticides in environmental sediment samples is described. The method was developed by the U.S. Geological Survey (USGS) in support of the National Water Quality Assessment (NAWQA) Program. The pesticides included in this method were chosen through prior prioritization. Herbicides, insecticides, and fungicides along with degradates are included in this method and span a variety of chemical classes including, but not limited to, chloroacetanilides, organochlorines, organophosphates, pyrethroids, triazines, and triazoles. Sediment samples are extracted by using an accelerated solvent extraction system (ASE®, and the compounds of interest are separated from co-extracted matrix interferences (including sulfur) by passing the extracts through high performance liquid chromatography (HPLC) with gel-permeation chromatography (GPC) along with the use of either stacked graphitized carbon and alumina solid-phase extraction (SPE) cartridges or packed Florisil®. Chromatographic separation, detection, and quantification of the pesticides from the sediment-sample extracts are done by using gas chromatography with mass spectrometry (GC/MS). Recoveries in test sediment samples fortified at 10 micrograms per kilogram (μg/kg) dry weight ranged from 75 to 102 percent; relative standard deviations ranged from 3 to 13 percent. Method detection limits (MDLs), calculated by using U.S. Environmental Protection Agency procedures (40 CFR 136, Appendix B), ranged from 0.6 to 3.4 μg/kg dry weight.

  8. Determination of volatile components in cut tobacco with gas chromatography-mass spectrometry and chemometric resolution

    Institute of Scientific and Technical Information of China (English)

    HUANG Lan-fang; WU Ming-jian; SUN Xian-jun; ZHONG Ke-jun; GUO Zi-ming; DAI Yun-hui; HUANG Ke-long; GUO Fang-qiu

    2007-01-01

    Chromatography-mass spectrometry (GC-MS) was used to analyze the volatile components of cut tobacco samples with the help of heuristic evolving latent projections (HELP). After extracting with simultaneous distillation and extraction method, the volatile components in cut tobacco were detected by GC-MS. Then the obtained original two-dimensional data were resolved into pure mass spectra and chromatograms. The qualitative analysis was performed by similarity searches in the national institute of standards and technology(NIST) mass database with the obtained pure mass spectrum of each component and the quantitative results were obtained by calculating the volume of total two-way response. The accuracy of qualitative and quantitative results were greatly improved by using the two-dimensional comprehensive information of chromatograms and mass spectra. 107 of 141 separated constituents in the total ion chromatogram of the volatile components were identified and quantified, accounting for about 88.01% of the total content. The result proves that the developed method is powerful for the analysis of complex cut tobacco samples.

  9. Qualitative Gas Chromatography-Mass Spectrometry Analyses Using Amines as Chemical Ionization Reagent Gases

    Science.gov (United States)

    Little, James L.; Howard, Adam S.

    2013-12-01

    Ammonia is a very useful chemical ionization (CI) reagent gas for the qualitative analyses of compounds by positive ion gas chromatography-mass spectrometry (GCMS). The gas is readily available, inexpensive, and leaves no carbon contamination in the MS source. Compounds of interest to our laboratory typically yield abundant protonated or ammoniated species, which are indicative of a compound's molecular weight. Nevertheless, some labile compounds fragment extensively by substitution and elimination reactions and yield no molecular weight information. In these cases, a CI reagent gas mixture of methylamine in methane prepared dynamically was found to be very useful in obtaining molecular weight data. Likewise, deuterated ammonia and deuterated methylamine are useful CI reagent gases for determining the exchangeable protons in organic compounds. Deuterated methylamine CI reagent gas is conveniently prepared by dynamically mixing small amounts of methylamine with excess deuterated ammonia.

  10. Gas chromatography-mass spectrometry analysis of various organic extracts ofMerremia borneensisfrom Sabah

    Institute of Scientific and Technical Information of China (English)

    M Amzad Hossain; Muhammad Dawood Shah; Mahyar Sakari

    2011-01-01

    Objective:To analyse the chemical composition of different extracts ofMerremia borneensis (M. borneensis) by gas chromatography-mass spectrometry (GC-MS).Methods: The dried leaves powder was extracted with methanol at room temperature by using Soxhlet extractor. Methanol crude extracts ofM. borneensis were extrastel with hexane, chloroform, ethyl acetate and butanol. Results: Qualitative analyses of various organic crude extracts showed that majority of these are flavonoids, terpeniods, alkaloids and glycosides. Most of the identified compounds by GC-MS are biologically important. Further theM. borneensisleaf possesses certain characteristics that can be ascribed to cultivation on a domestic plantation.Conclusions: The suitable extracts for respective compounds can be chosen on the basis of aboveGC-MS analysis. All the major compounds from different extracts are biologically active molecules. Thus the identification of a good number of compounds from various extractsM. borneensis might have some ecological significance.

  11. Identification of 19 phthalic acid esters in dairy products by gas chromatography with mass spectrometry.

    Science.gov (United States)

    Wu, Pinggu; Cai, Chenggang; Yang, Dajin; Wang, Liyuan; Zhou, Yan; Shen, Xianghong; Ma, Bingjie; Tang, Jun

    2015-01-01

    A detection method for 19 kinds of phthalic acid ester compounds analyzed by n-hexane/ether/acetonitrile 1:7:8 v/v/v mixed solvent extraction, quick, easy, cheap, effective, rugged, and safe purification and internal standard method of quantitative gas chromatography with mass spectrometry was established. This method can effectively remove interfering materials, such as lipids, fatty acids, and pigments, from dairy products. The 19 kinds of phthalic acid ester compounds were within a 0.025-0.2 mg/kg range, the recovery rate was 65.2-125.7%, relative standard deviation was 7.9-15.4% (n = 6), and the limit of detection was 0.005-0.02 mg/kg. Concentrations of the 19 kinds of phthalic acid ester compounds ranged between 0.01 and 0.12 mg/kg in ten dairy materials and 20 dairy products. The established method is simple, rapid, accurate, and highly sensitive.

  12. Multimycotoxin analysis in water and fish plasma by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tolosa, J; Font, G; Mañes, J; Ferrer, E

    2016-02-01

    High performance liquid chromatography-mass spectrometry was used for the determination of 15 mycotoxins in water and fish plasma samples, including aflatoxins, fumonisins, ochratoxin A, sterigmatocistin, fusarenon-X and emerging Fusarium mycotoxins. In this work, dispersive liquid-liquid microextraction (DLLME) was assessed as a sample treatment for the simultaneous extraction of mycotoxins. Results showed differences in recovery assays when different extraction solvents were employed. Ethyl acetate showed better recoveries for the major part of mycotoxins analyzed, except for aflatoxins B2, G1 and G2, which showed better recoveries when employing chloroform as extractant solvent. Fumonisins and beauvericin exhibited low recoveries in both water and plasma. This method was validated according to guidelines established by European Commission and has shown to be suitable to be applied in dietary and/or toxicokinetic studies in fish where is necessary to check mycotoxin contents in rearing water and fish plasma.

  13. Confirmatory analysis of firocoxib in bovine milk by rapid resolution liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Dowling, Geraldine; Gallo, Pasquale; Regan, Liam

    2009-02-15

    A rapid method has been developed to analyse for firocoxib (FIRO) residue in bovine milk. Milk samples were extracted with acetonitrile and sample extracts were purified on Evolute ABN solid phase extraction cartridges. Aliquots were analysed by rapid resolution liquid chromatography tandem mass spectrometry (RRLC-MS/MS). The method was validated in bovine milk, according to the criteria defined in Commission Decision 2002/657/EC. The decision limit (CCalpha) was 1.18ng/mL and for the detection capability a (CCbeta) value of 2.02ng/mL was obtained. The measurement uncertainty of the method was 27%. Fortifying bovine milk samples (n=18) in three separate assays, show the accuracy of the method to be between 96 and 105%. The precision of the method, expressed as RSD values for the within-lab reproducibility at the three levels of fortification (5, 7.5 and 10ng/mL) was less than 11% respectively.

  14. Determination of dapsone in meat and milk by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Hadjigeorgiou, M; Papachrysostomou, Ch; Theodorou, Z; Kanari, P; Constantinou, S

    2009-04-01

    Within the EU the use of dapsone (4,4-diaminodiphenylsulfone) is prohibited in food-producing animals and consequently it's included in the Annex IV of the Directive 90/2377/EC. A quantitative confirmatory method has been developed and validated according to the criteria defined in the Commission Decision 2002/657/EC, for the determination of dapsone in meat and milk. Samples, after homogenization in alkaline conditions and organic solvent extraction, were purified on silica gel solid phase extraction cartridges. The eluate was evaporated and redissolved in mobile phase and was analysed by liquid chromatography tandem mass spectrometry (LC-MS/MS) in positive electrospray ionisation (ESI) using deuterium labelled Sulphadimidine-d7 as internal standard. The calculated value for, decision limit, CCalpha is 0.12 microgkg(-1), and the detection capability; CCbeta value is 0.16 microgkg(-1).

  15. Determination of dapsone in meat and milk by liquid chromatography tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hadjigeorgiou, M. [State General Laboratory of Cyprus, Veterinary Drug Residues Lab, Kimonos 44, 1451 Nicosia (Cyprus)], E-mail: mhadjigeorgiou@sgl.moh.gov.cy; Papachrysostomou, Ch.; Theodorou, Z.; Kanari, P.; Constantinou, S. [State General Laboratory of Cyprus, Veterinary Drug Residues Lab, Kimonos 44, 1451 Nicosia (Cyprus)

    2009-04-01

    Within the EU the use of dapsone (4,4-diaminodiphenylsulfone) is prohibited in food-producing animals and consequently it's included in the Annex IV of the Directive 90/2377/EC. A quantitative confirmatory method has been developed and validated according to the criteria defined in the Commission Decision 2002/657/EC, for the determination of dapsone in meat and milk. Samples, after homogenization in alkaline conditions and organic solvent extraction, were purified on silica gel solid phase extraction cartridges. The eluate was evaporated and redissolved in mobile phase and was analysed by liquid chromatography tandem mass spectrometry (LC-MS/MS) in positive electrospray ionisation (ESI) using deuterium labelled Sulphadimidine-d7 as internal standard. The calculated value for, decision limit, CC{alpha} is 0.12 {mu}g kg{sup -1}, and the detection capability; CC{beta} value is 0.16 {mu}g kg{sup -1}.

  16. Subsurface detection of fossil fuel pollutants by photoionization and gas chromatography/mass spectrometry.

    Science.gov (United States)

    Robbat, Albert; Considine, Thomas; Antle, Patrick M

    2010-09-01

    This paper describes analysis of environmental pollutants at depth without bringing sample to the surface. It is based on an improved 3-stage Peltier freeze trap, which efficiently pre-concentrates volatile coal tar and petroleum hydrocarbons, and an integrated system for detecting pollutants on-line, in real-time by photoionization detection and quantitation by gas chromatography/mass spectrometry (GC/MS) as the probe is advanced into the subsurface. Findings indicate measurement precision and accuracy for volatiles meet EPA criteria for hazardous waste site investigations. When a Teflon membrane inlet is used to detect contaminants in groundwater, its 140 degrees C temperature limit restricts analyte collection in soil to C(2)-phenanthrenes. Two case studies demonstrate the probe is well-suited to tracking petroleum and coal tar plumes from source to groundwater.

  17. Analysis of bromate in drinking water using liquid chromatography-tandem mass spectrometry without sample pretreatment.

    Science.gov (United States)

    Kosaka, Koji; Asami, Mari; Takei, Kanako; Akiba, Michihiro

    2011-01-01

    An analytical method for determining bromate in drinking water was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The (18)O-enriched bromate was used as an internal standard. The limit of quantification (LOQ) of bromate was 0.2 µg/L. The peak of bromate was separated from those of coexisting ions (i.e., chloride, nitrate and sulfate). The relative and absolute recoveries of bromate in two drinking water samples and in a synthesized ion solution (100 mg/L chloride, 10 mg N/L nitrate, and 100 mg/L sulfate) were 99-105 and 94-105%, respectively. Bromate concentrations in 11 drinking water samples determined by LC-MS/MS were water without sample pretreatment.

  18. Amino acid analysis in micrograms of meteorite sample by nanoliquid chromatography-high-resolution mass spectrometry.

    Science.gov (United States)

    Callahan, Michael P; Martin, Mildred G; Burton, Aaron S; Glavin, Daniel P; Dworkin, Jason P

    2014-03-07

    Amino acids and their enantiomers in a 360 microgram sample of Murchison meteorite were unambiguously identified and quantified using chemical derivatization and nanoliquid chromatography coupled to nanoelectrospray ionization high resolution orbitrap mass spectrometry techniques. The distribution and abundance of amino acids were similar to past studies of Murchison meteorite but the samples used here were three orders of magnitude lower. The analytical method was also highly sensitive, and some amino acid reference standards were successfully detected at a level of ∼200 attomoles (on column). These results may open up the possibility for investigating other less studied, sample-limited extraterrestrial samples (e.g., micrometeorites, interplanetary dust particles, and cometary particles) for biologically-relevant organic molecules.

  19. Rapid quantification of dimethyl methylphosphonate from activated carbon particles by static headspace gas chromatography mass spectrometry.

    Science.gov (United States)

    Mitchell, Brendan L; Billingsley, Brit G; Logue, Brian A

    2013-06-01

    Activated carbon (AC) particles are utilized as an adsorbent for binding hazardous vapors in protective equipment. The binding affinity and utilization of these AC particles should be known to ensure effective and efficient use. Therefore, a simple and effective method was developed for the quantification of the chemical warfare agent simulant, dimethyl methylphosphonate (DMMP), from AC particles. Static headspace gas chromatography mass-spectrometry with internal standard, DMMP-d6, was used to perform the analysis. The method produced a linear dynamic range of 2.48-620g DMMP/kg carbon and a detection limit of 1.24g DMMP/kg carbon. Furthermore, the method produced a coefficient of variation of less than 16% for all intra- and inter-assay analyses. The method provided a simple and effective procedure for quantifying DMMP from AC particles and was applied to the analysis of a DMMP-exposed AC protective respirator filter.

  20. The Application of Resonance-Enhanced Multiphoton Ionization Technique in Gas Chromatography Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Adan Li

    2014-01-01

    Full Text Available Gas chromatography resonance-enhanced multiphoton ionization time-of-flight mass spectrometry (GC/REMPI-TOFMS using a nanosecond laser has been applied to analyze the 16 polycyclic aromatic hydrocarbons (PAHs. The excited-state lifetime, absorption characters, and energy of electronic states of the 16 PAHs were investigated to optimize the ionization yield. A river water sample pretreated by means of solid phase extraction was analyzed to evaluate the performance of the analytical instrument. The results suggested that REMPI is superior to electron impact ionization method for soft ionization and suppresses the background signal due to aliphatic hydrocarbons. Thus, GC/REMPI-TOFMS is a more reliable method for the determination of PAHs present in the environment.

  1. Simultaneous determination of amphetamines and ketamines in urine by gas chromatography/mass spectrometry.

    Science.gov (United States)

    Lin, Huei Ru; Lua, Ahai Chang

    2006-01-01

    A method for the simultaneous determination of amphetamines and ketamines (ketamine, norketamine and dehydronorketamine) in urine samples by gas chromatography/mass spectrometry was developed and validated. Urine samples were extracted with organic solvent and derivatized with trifluoroacetic anhydride (TFAA). The limits of detection and limits of quantification for each analyte were lower than 19 and 30 ng/mL, respectively. Within-day and between-day precisions were within 0.5% and 10.6%, respectively. Biases for three levels of control samples were within -10.6% and +7.8%. The concentration of dehydronorketamine was greater than those of ketamine or norketamine in 19 of 35 ketamine-positive samples. A group of 110 human urine samples previously determined to contain at least one of the target analytes was analyzed using the new method, and excellent agreement was observed with previous results.

  2. Gas chromatography/mass spectrometry for the determination of nitrosamines in red wine.

    Science.gov (United States)

    Lona-Ramirez, Fernando J; Gonzalez-Alatorre, Guillermo; Rico-Ramírez, Vicente; Perez-Perez, Ma Cristina I; Castrejón-González, Edgar O

    2016-04-01

    N-nitrosamines (NAms) are highly active carcinogens that have been detected in food and beverages. Currently certain studies report their presence in red wine, while others fail to detect their presence. In this study the head space solid phase micro-extraction technique coupled to gas chromatography-mass spectrometry (HS-SPME-GC-MS) was applied to quantify four NAms in different types of red wine. The technique was found to be a simple, precise, fast and environmentally friendly alternative for the quantification of volatile NAms. A factorial analysis was carried out to evaluate the influence of the parameters on the HS-SPME technique. This is the first study that such analysis has been reported and where NAms in red wine have been quantified using HS-SPME-GC-MS. The method was validated by calculating the linearity, limit of detection and quantification. Two of the four NAms analyzed were found to be present in red wine samples.

  3. Current Applications of Liquid Chromatography/Mass Spectrometry in Pharmaceutical Discovery After a Decade of Innovation

    Science.gov (United States)

    Ackermann, Bradley L.; Berna, Michael J.; Eckstein, James A.; Ott, Lee W.; Chaudhary, Ajai K.

    2008-07-01

    Current drug discovery involves a highly iterative process pertaining to three core disciplines: biology, chemistry, and drug disposition. For most pharmaceutical companies the path to a drug candidate comprises similar stages: target identification, biological screening, lead generation, lead optimization, and candidate selection. Over the past decade, the overall efficiency of drug discovery has been greatly improved by a single instrumental technique, liquid chromatography/mass spectrometry (LC/MS). Transformed by the commercial introduction of the atmospheric pressure ionization interface in the mid-1990s, LC/MS has expanded into almost every area of drug discovery. In many cases, drug discovery workflow has been changed owing to vastly improved efficiency. This review examines recent trends for these three core disciplines and presents seminal examples where LC/MS has altered the current approach to drug discovery.

  4. Enhancement of the capabilities of liquid chromatography-mass spectrometry with derivatization: general principles and applications.

    Science.gov (United States)

    Xu, Fengguo; Zou, Li; Liu, Ying; Zhang, Zunjian; Ong, Choon Nam

    2011-01-01

    The integration of liquid chromatography-mass spectrometry (LC-MS) with derivatization is a relatively new and unique strategy that could add value and could enhance the capabilities of LC-MS-based technologies. The derivatization process could be carried out in various analytical steps, for example, sampling, storage, sample preparation, HPLC separation, and MS detection. This review presents an overview of derivatization-based LC-MS strategy over the past 10 years and covers both the general principles and applications in the fields of pharmaceutical and biomedical analysis, biomarker and metabolomic research, environmental analysis, and food-safety evaluation. The underlying mechanisms and theories for derivative reagent selection are summarized and highlighted to guide future studies.

  5. Melatonin in edible plants identified by radioimmunoassay and by high performance liquid chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dubbels, R.; Klenke, E.; Schnakenberg, E.; Ehlers, C.; Schloot, W. [Univ. of Bremen, Center of Human Genetics and Genetic Counselling, Bremen (Germany); Reiter, R.J. [The Univ. of Texas Health Science Center at San Antonio, Dept. of Cellular and Structural Biology, San Antonio, Texas (United States); Goebel, A.; Schiware, H.W. [Gemeinschaftslabor Dr. Schiwara et al., Breman (Germany)

    1995-01-01

    Melatonin, the chief hormone of the pineal gland in vertebrates, is widely distributed in the animal kingdom. Among many functions, melatonin synchronizes circadian and circannual rhythms, stimulates immune function, may increase life span, inhibits growth of cancer cells in vitro and cancer progression and promotion in vivo, and was recently shown to be a potent hydroxyl radical scavenger and antioxidant. Hydroxyl radicals are highly toxic by-products of oxygen metabolism that damage cellular DNA and other macromolecules. Herein we report that melatonin, in varying concentrations, is also found in a variety of plants. Melatonin concentrations, measured in nine different plants by radioimmunoassay, ranged from 0 to 862 pg melatonin/mg protein. The presence of melatonin was verified by gas chromatography/mass spectrometry. Our findings suggest that the consumption of plant materials that contain high levels of melatonin could alter blood melatonin levels of the indole as well as provide protection of macromolecules against oxidative damage. (au) 30 refs.

  6. Determination of salvinorins and divinatorins in Salvia divinorum leaves by liquid chromatography/multistage mass spectrometry.

    Science.gov (United States)

    Medana, Claudio; Massolino, Cristina; Pazzi, Marco; Baiocchi, Claudio

    2006-01-01

    Salvinorin A is the most potent naturally occurring hallucinogen known and rivals synthetic LSD in potency. Structurally it belongs to the neoclerodane diterpenoids, and it is the only known non-nitrogenous kappa-opioid-selective agonist. Salvia divinorum (Diviner's sage) is a member of the mint family that was used in ancient Mexican traditional practices. Today it is widely cultivated in Europe as a recreational marijuana substitute; it is illegal to buy, sell or possess the plant or the active principle in some countries. Six different salvinorins and three divinatorins have been isolated from Salvia divinorum leaves. The ion fragmentation, separation and quantitation of these diterpenes by liquid chromatography/electrospray ionization multistage mass spectrometry (LC/ESI-MS(n)) are described. The importance of LC in herbal extract determination and the chemical diagnostic power of MS(n) in the analysis of classes of natural organic products are discussed.

  7. Determination of Sex Hormones in Antler Velvet by High Performance Liquid Chromatography Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    LU Chun-mei; WANG Ming-tai; MU Jun; BAI Yu-ping; DU Jian-shi; ZHANG Han-qi; WANG Jian-wei

    2012-01-01

    Eighteen sex hormones in antler velvet were determined by high performance liquid chromatography tandem mass spectrometry.The solid phase extraction was applied to eliminating the matrix effect.The experimental conditions were examined and optimized.Under the optimal conditions,the proposed method provides the good linearities and determination limits(0.2-1.0 μg/kg)of the analytes investigated.The recoveries ranging from 72.3% to 149.5% were obtained for the target analytes at two concentration levels.This method was applied to the determination of eighteen sex hormones in different kinds of antler velvet samples and the obtained results are satisfactory.The results indicate that the proposed method is suitable for the determination of sex hormones in antler velvet samples.

  8. Use of Gas Chromatography-Mass Spectrometry (GC-MS) in Nonscience Major Course Laboratory Experiments

    Science.gov (United States)

    Kostecka, Keith S.; Lerman, Zafra M.; Angelos, Sanford A.

    1996-06-01

    Gas chromatography-mass spectrometry (GC-MS) has been utilized with nonscience majors in the courses: "Modern Methods in Science: Discovering Molecular Secrets"; "The Extraordinary Chemistry of Ordinary Things"; "From Ozone to Oil Spills: Chemistry, the Environment and You"; and "Crime Lab Chemistry: Solving Crime through Analytical Chemistry". Our efforts have centered on introducing prospective science communicators (film, video, radio, television, and journalism majors) to science relative to their majors and personal interests. Quality lecture-discussion topics, "mystery"-based laboratory activities have assisted in introducing and/or explaining specific areas of chemistry that attempt to reduce fear of subject matter. Students have also used GC-MS, as a form of alternative assessment, in course projects that have been based on their majors, personal interests, and cultural backgrounds. Students have also conducted advanced independent work in different areas of chemistry, including the analysis of nail polishes and lacquers and eleven aromatic compounds present in three different brands of gasoline.

  9. Phytochemical analysis of Hibiscus caesius using high performance liquid chromatography coupled with mass spectrometry.

    Science.gov (United States)

    Ain, Quratul; Naveed, Muhammad Na; Mumtaz, Abdul Samad; Farman, Muhammad; Ahmed, Iftikhar; Khalid, Nauman

    2015-09-01

    Various species in genus Hibiscus are traditionally known for their therapeutic attributes. The present study focused on the phytochemical analysis of a rather unexplored species Hibiscus caesius (H. caesius), using high-pressure liquid chromatography coupled with mass spectrometry (HPLC-MS). The analysis revealed five major compounds in the aqueous extract, viz. vanillic acid, protocatechoic acid, quercetin, quercetin glucoside and apigenin, being reported for the first time in H. caesius. Literature suggests that these compounds have important pharmacological traits such as anti-cancer, anti-inflammatory, anti-bacterial and hepatoprotective etc. however, this requires further pharmacological investigations at in vitro and in vivo scale. The above study concluded the medicinal potential of H. caesius.

  10. Determination of Hexachlorocyclohexane by Gas Chromatography Combined with Femtosecond Laser Ionization Mass Spectrometry

    Science.gov (United States)

    Yang, Xixiang; Imasaka, Tomoko; Li, Adan; Imasaka, Totaro

    2016-09-01

    Structural isomers and enantiomers of hexachlorocyclohexane (HCH) were separated using a chiral column by gas chromatography and quantitatively determined by multiphoton ionization mass spectrometry using an ultraviolet femtosecond laser (200 and 267 nm) as the ionization source. The order of elution of the enantiomers (i.e., (+)-α-HCH and (-)-α-HCH) was predicted from stabilization energies calculated for the complexes using permethylated γ-cyclodextrin as the stationary phase of the column, and the results were compared with the experimental data. The molecular ions observed for HCH were weak, even though they can be ionized through a process of resonance enhanced two-photon ionization at 200 nm. This unfavorable result can be attributed to the dissociation of the molecular ion, as predicted from quantum chemical calculations.

  11. Saffron authentication based on liquid chromatography high resolution tandem mass spectrometry and multivariate data analysis.

    Science.gov (United States)

    Rubert, Josep; Lacina, Ondrej; Zachariasova, Milena; Hajslova, Jana

    2016-08-01

    Saffron is one of the oldest and most expensive spices, which is often target of fraudulent activities. In this research, a new strategy of saffron authentication based on metabolic fingerprinting was developed. In the first phase, a solid liquid extraction procedure was optimized, the main aim was to isolate as maximal representation of small molecules contained in saffron as possible. In the second step, a detection method based on liquid chromatography coupled with high-resolution mass spectrometry was developed. Initially, principal component analysis (PCA) revealed clear differences between saffron cultivated and packaged in Spain, protected designation of origin (PDO), and saffron packaged in Spain of unknown origin, labeled Spanish saffron. Afterwards, orthogonal partial least square discriminant analysis (OPLS-DA) was favorably used to discriminate between Spanish saffron. The tentative identification of markers showed glycerophospholipids and their oxidized lipids were significant markers according to their origin.

  12. Simultaneous determination of steviol and steviol glycosides by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Shah, Romina; De Jager, Lowri S; Begley, Timothy H

    2012-01-01

    A direct, versatile method for the determination of steviol and nine steviol glycosides in food products has been developed by using electrospray ionisation liquid chromatography-mass spectrometry in the negative-ion mode. Ten stevia compounds were readily separated on an amino column by using a gradient separation. Data for analyte quantification were collected in the selected ion monitoring mode, giving the method limit of detection of 0.01-0.34 µg g⁻¹ and repeatability at the limit of quantitation of 2%-15% relative standard deviation. Thirty-four commercially available food products were tested by using the optimised method, and in these products rebaudioside A and stevioside comprised 52%-100% of the total steviol glycosides. Multiple reaction monitoring data were collected to provide analyte confirmation. Stability data for rebaudioside A stored at room temperature, 40°C and 60°C over a period of 1-14 days are shown.

  13. Pressurized liquid extraction followed by liquid chromatography with tandem mass spectrometry to determine pharmaceuticals in mussels.

    Science.gov (United States)

    Núñez, Mireia; Borrull, Francesc; Pocurull, Eva; Fontanals, Núria

    2016-02-01

    An analytical method based on pressurized liquid extraction and solid-phase extraction with a mixed-mode Oasis(®) MAX sorbent as cleanup, followed by liquid chromatography with electrospray ionization and tandem mass spectrometry was developed and validated for the determination of seven widely used pharmaceuticals in mussel species. The optimization of the pressurized liquid extraction and the solid-phase extraction parameters is described. The method provided extraction recoveries ranging from 61 to 90%, and limits of detection ranging from 2 to 50 ng/g (dry weight). The repeatability and reproducibility of the method, expressed as relative standard deviation, were lower than 15 and 19%, respectively. The method was successfully applied to the analysis of mussel samples from different locations. The analyses showed that salicylic acid was present in mussels at concentrations up to 177 ng/g (dry weight).

  14. Method for (236)U Determination in Seawater Using Flow Injection Extraction Chromatography and Accelerator Mass Spectrometry.

    Science.gov (United States)

    Qiao, Jixin; Hou, Xiaolin; Steier, Peter; Nielsen, Sven; Golser, Robin

    2015-07-21

    An automated analytical method implemented in a flow injection (FI) system was developed for rapid determination of (236)U in 10 L seawater samples. (238)U was used as a chemical yield tracer for the whole procedure, in which extraction chromatography (UTEVA) was exploited to purify uranium, after an effective iron hydroxide coprecipitation. Accelerator mass spectrometry (AMS) was applied for quantifying the (236)U/(238)U ratio, and inductively coupled plasma mass spectrometry (ICPMS) was used to determine the absolute concentration of (238)U; thus, the concentration of (236)U can be calculated. The key experimental parameters affecting the analytical effectiveness were investigated and optimized in order to achieve high chemical yields and simple and rapid analysis as well as low procedure background. Besides, the operational conditions for the target preparation prior to the AMS measurement were optimized, on the basis of studying the coprecipitation behavior of uranium with iron hydroxide. The analytical results indicate that the developed method is simple and robust, providing satisfactory chemical yields (80-100%) and high analysis speed (4 h/sample), which could be an appealing alternative to conventional manual methods for (236)U determination in its tracer application.

  15. Characterization of the limonene oxidation products with liquid chromatography coupled to the tandem mass spectrometry

    Science.gov (United States)

    Witkowski, Bartłomiej; Gierczak, Tomasz

    2017-04-01

    Composition of the secondary organic aerosol (SOA) generated during ozonolysis of limonene was investigated with liquid chromatography coupled to the negative electrospray ionization (ESI), quadrupole tandem mass spectrometry (MS/MS) as well as high resolution Time-of-Flight mass spectrometry. Aerosol was generated in the flow-tube reactor. HR-MS/MS analysis allowed for proposing structures for the several up-to-date unknown limonene oxidation products. In addition to the low MW limonene oxidation products, significant quantities of oligomers characterized by elemental compositions: C19H30O5, C18H28O6, C19H28O7, C19H30O7 and C20H34O9 were detected in the SOA samples. It was concluded that these compounds are most likely esters, aldol reaction products and/or hemiacetals. In addition to detailed study of the limonene oxidation products, the reaction time as well as initial ozone concentration impact on the limonene SOA composition was investigated. The relative intensities of the two esters of the limonic acid and 7-hydroxy limononic acid increased as a result of lowering the initial ozone concentration and shortening the reaction time, indicating that esterification may be an important oligomerization pathway during limonene SOA formation.

  16. Rapid Preconcentration for Liquid Chromatography-Mass Spectrometry Assay of Trace Level Neuropeptides

    Science.gov (United States)

    Zhou, Ying; Mabrouk, Omar S.; Kennedy, Robert T.

    2013-11-01

    Measurement of neuropeptides in the brain through in vivo microdialysis sampling provides direct correlation between neuropeptide concentration and brain function. Capillary liquid chromatography-multistage mass spectrometry (CLC-MSn) has proven to be effective at measuring endogenous neuropeptides in microdialysis samples. In the method, microliter samples are concentrated onto nanoliter volume packed beds before ionization and mass spectrometry analysis. The long times required for extensive preconcentration present a barrier to routine use because of the many samples that must be analyzed and instability of neuropeptides. In this study, we evaluated the capacity of 75 μm inner diameter (i.d.) capillary column packed with 10 μm reversed phase particles for increasing the throughput in CLC-MSn based neuropeptide measurement. Coupling a high injection flow rate for fast sample loading/desalting with a low elution flow rate to maintain detection sensitivity, this column has reduced analysis time from ˜30 min to 3.8 min for 5 μL sample, with 3 pM limit of detection (LOD) for enkephalins and 10 pM LOD for dynorphin A1-8 in 5 μL sample. The use of isotope-labeled internal standard lowered peptide signal variation to less than 5 %. This method was validated for in vivo detection of Leu and Met enkephalin with microdialysate collected from rat globus pallidus. The improvement in speed and stability makes CLC-MSn measurement of neuropeptides in vivo more practical.

  17. [Determination of glyphosate and aminomethylphosphonic acid in rice using liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Cao, Zhaoyun; Mou, Renxiang; Chen, Mingxue

    2010-08-01

    A method was developed for the determination of glyphosate (GLY) and aminomethylphosphonic acid (AMPA) in rice using liquid chromatography tandem mass spectrometry (LC-MS/MS). The sample was extracted with water followed by a simple cleanup with a C18 solid phase extraction (SPE) cartridge, and then GLY and AMPA were derivatized using 9-fluorenylmethoxycarbonyl (FMOC-Cl) in borate buffer. The derivatives of GLY and AMPA were separated on a C18 column with gradient elution with the mobile phase of acetonitrile and 5 mmol/L ammonium acetate (pH 9), and finally detected with negative ion electrospray ionization-mass spectrometry (ESI-MS) in multiple reaction monitoring (MRM) mode. The results showed that the linearities of GLY and AMPA were in the concentration range of 0.000 50 to 1.0 mg/L with the correlation coefficients of 0.999 7 and 0.999 9, respectively. The mean spiked recoveries of GLY and AMPA at 3 spiked levels ranged from 72.5% to 113.6% with the relative standard deviations (RSD, n = 5) of 3.8% - 16.2%. The limits of detection were 2.0 and 3.0 microg/kg for GLY and AMPA, respectively. This method is rapid, sensitive, and suitable for simultaneous determination of GLY and AMPA in rice.

  18. Integration of continuous-flow accelerator mass spectrometry with chromatography and mass-selective detection.

    Science.gov (United States)

    Flarakos, Jimmy; Liberman, Rosa G; Tannenbaum, Steven R; Skipper, Paul L

    2008-07-01

    Physical combination of an accelerator mass spectrometry (AMS) instrument with a conventional gas chromatograph-mass spectrometer (GC/MS) is described. The resulting hybrid instrument (GC/MS/AMS) was used to monitor mass chromatograms and radiochromatograms simultaneously when (14)C-labeled compounds were injected into the gas chromatograph. Combination of the two instruments was achieved by splitting the column effluent and directing half to the mass spectrometer and half to a flow-through CuO reactor in line with the gas-accepting AMS ion source. The reactor converts compounds in the GC effluent to CO2 as required for function of the ion source. With cholesterol as test compound, the limits of quantitation were 175 pg and 0.00175 dpm injected. The accuracy achieved in analysis of five nonzero calibration standards and three quality control standards, using cholesterol-2,2,3,4,4,6-d6 as injection standard, was 100 +/- 11.8% with selected ion monitoring and 100 +/- 16% for radiochromatography. Respective values for interday precision were 1.0-3.2 and 22-32%. Application of GC/MS/AMS to a current topic of interest was demonstrated in a model metabolomic study in which cultured primary hepatocytes were given [(14)C]glucose and organic acids excreted into the culture medium were analyzed.

  19. Analysis of paralytic shellfish toxins using high-field asymmetric waveform ion mobility spectrometry with liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Beach, Daniel G; Melanson, Jeremy E; Purves, Randy W

    2015-03-01

    The analysis of paralytic shellfish toxins (PSTs) by liquid chromatography-mass spectrometry remains a challenge because of their high polarity, large number of analogues and the complex matrix in which they occur. Here we investigate the potential utility of high-field asymmetric waveform ion mobility spectrometry (FAIMS) as a gas-phase ion separation tool for analysis of PSTs by mass spectrometry. We investigate the separation of PSTs using FAIMS with two divergent goals: using FAIMS as a primary separation tool for rapid screening by electrospray ionization (ESI)-FAIMS-MS or combined with LC in a multidimensional LC-ESI-FAIMS-MS separation. First, a survey of the parameters that affect the sensitivity and selectivity of PST analysis by FAIMS was carried out using ESI-FAIMS-MS. In particular, the use of acetonitrile as a gas additive in the carrier gas flow offered good separation of all PST epimeric pairs. A second set of FAIMS conditions was also identified, which focussed PSTs to a relatively narrow CV range allowing development of an LC-ESI-FAIMS-MS method for analysis of PST toxins in complex mussel tissue extracts. The quantitative capabilities of this method were evaluated by analysing a PST containing mussel tissue matrix material. Results compared favourably with analysis by an established LC-post-column oxidation-fluorescence method with recoveries ranging from 70 to 106%, although sensitivity was somewhat reduced. The current work represents the first successful separation of PST isomers using ion mobility and shows the promise of FAIMS as a tool for analysis of algal biotoxins in complex samples and outlines some critical requirements for its future improvement.

  20. Determination of polar pesticides in olive oil and olives by hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry and high resolution mass spectrometry.

    Science.gov (United States)

    Nortes-Méndez, Rocío; Robles-Molina, José; López-Blanco, Rafael; Vass, Andrea; Molina-Díaz, Antonio; Garcia-Reyes, Juan F

    2016-09-01

    This article reports the development of two HPLC-MS methods for the determination of polar pesticides in olive oil and olive samples by hydrophilic interaction liquid chromatography (HILIC) separation followed by mass spectrometry detection with tandem mass spectrometry using a triple quadrupole instrument operated in multiple reaction monitoring mode (HILIC-MS/MS) or electrospray time-of-flight mass spectrometry (HILIC-TOFMS). The selected polar pesticides included in the study were: amitrol, cyromazine, diquat, paraquat, mepiquat, trimethylsulfonium (trimesium, glyphosate counterion) and fosetyl aluminium. The simple sample treatment procedure was based on liquid partitioning with methanol. The performance of the sample extraction was evaluated in terms of recovery rates and matrix effects in both olive oil and olives matrices. The results obtained for olive oil were satisfactory while, due to the high complexity of olives, poor recovery rates were obtained for the extraction of diquat, paraquat and amitrol, although with a reasonable precision enabling its use in routine analysis. Similarly, matrix effects were minor in the case of olive oil (ca. 20% suppression average), while significantly higher suppression was observed for olives (30-50% suppression average). The studied approaches were found to be useful for the determination of the pesticides studied in olive oil and olives with limits of quantitation below 5µgkg(-1) in most cases when tandem mass spectrometry was used, thus being in compliance with MRLs set by current EU regulation.

  1. Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Douglas C., E-mail: douglas.baxter@alsglobal.com [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Faarinen, Mikko [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Osterlund, Helene; Rodushkin, Ilia [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Division of Geosciences, Lulea University of Technology, 977 87 Lulea (Sweden); Christensen, Morten [ALS Scandinavia AB, Maskinvaegen 2, 183 53 Taeby (Sweden)

    2011-09-09

    Highlights: {center_dot} We determine methylmercury in serum and plasma using isotope dilution calibration. {center_dot} Separation by gas chromatography and detection by inductively coupled plasma mass spectrometry. {center_dot} Data for 50 specimens provides first reference range for methylmercury in serum. {center_dot} Serum samples shown to be stable for 11 months in refrigerator. - Abstract: A method for the determination of methylmercury in plasma and serum samples was developed. The method uses isotope dilution with {sup 198}Hg-labeled methylmercury, extraction into dichloromethane, back-extraction into water, aqueous-phase ethylation, purge and trap collection, thermal desorption, separation by gas chromatography, and mercury isotope specific detection by inductively coupled plasma mass spectrometry. By spiking 2 mL sample with 1.2 ng tracer, measurements in a concentration interval of (0.007-2.9) {mu}g L{sup -1} could be performed with uncertainty amplification factors <2. A limit of quantification of 0.03 {mu}g L{sup -1} was estimated at 10 times the standard deviation of concentrations measured in preparation blanks. Within- and between-run relative standard deviations were <10% at added concentration levels of 0.14 {mu}g L{sup -1}, 0.35 {mu}g L{sup -1} and 2.8 {mu}g L{sup -1}, with recoveries in the range 82-110%. Application of the method to 50 plasma/serum samples yielded a median (mean; range) concentration of methylmercury of 0.081 (0.091; <0.03-0.19) {mu}g L{sup -1}. This is the first time methylmercury has been directly measured in this kind of specimen, and is therefore the first estimate of a reference range.

  2. Liquid chromatography-bioassay-mass spectrometry for profiling of physiologically active food.

    Science.gov (United States)

    Morlock, Gertrud E; Klingelhöfer, Ines

    2014-08-19

    Complex samples like food contain thousands of single compounds. In the past, only known target compounds were looked for; however, most bioactive compounds in food are unknown. On the contrary, nontarget analyses face the challenge of determining the thousand peaks' identities, but it remains largely unclear which peaks are bioactive. Here, we show a novel effect-directed food profiling, as food and food supplements can be unknowingly physiologically active. By the combination of planar chromatography, using water-wettable reversed phase high-performance thin-layer chromatography (HPTLC RP18 W) plates, with detection by specific microorganisms, endocrine compounds in food were quantitatively detected as sharp-bounded zones and further characterized by mass spectrometry. This analytical workflow allowed frequent food intakes to be identified as risky with regard to estrogen-effective compounds, in discussion for their potential involvement in foodborne pathogenesis and for use in personalized health care. Using this accelerated workflow with its comprehensive detection potential, unknown endocrine compounds can be discovered. Exemplarily, the discovery of up to six endocrine disrupting compounds was shown in seven propolis samples and in four spices. For example, microorganisms quantitatively detected an estrogen-effective compound in the range of 0.07-0.24% in seven propolis samples, which was assigned to be caffeic acid phenethyl ester by mass spectrometry. This streamlined nontarget analysis detected modes of action, followed by targeted characterization of newly discovered effective compounds. Also, drug discovery or analysis of traditional medicines may profit from this effect-directed profiling of complex samples.

  3. Americium and plutonium separation by extraction chromatography for determination by accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kazi, Zakir H. [Department of Earth Science, University of Ottawa, 140 Louis Pasteur Avenue, Ottawa K1N 6N5 (Canada); Cornett, Jack R., E-mail: jack.cornett@uottawa.ca [Department of Earth Science, University of Ottawa, 140 Louis Pasteur Avenue, Ottawa K1N 6N5 (Canada); Zhao, Xaiolei; Kieser, Liam [Department of Physics, University of Ottawa, 140 Louis Pasteur Avenue, Ottawa K1N 6N5 (Canada)

    2014-06-01

    Highlights: • Am and Pu were adsorbed and separated using a single extraction chromatography DGA column. • Pu was eluted from the column completely using on-column reduction of Pu(IV) to Pu(III). • ²⁴¹Am and 239,240Pu measurements by accelerator mass spectrometry (AMS) agree with the certified values in two SRMs. Abstract: A simple method was developed to separate Pu and Am using single column extraction chromatography employing N,N,N',N'-tetra-n-octyldiglycolamide (DGA) resin. Isotope dilution measurements of Am and Pu were performed using accelerator mass spectrometry (AMS) and alpha spectrometry. For maximum adsorption Pu was stabilized in the tetra valent oxidation state in 8 M HNO₃ with 0.05 M NaNO₂ before loading the sample onto the resin. Am(III) was adsorbed also onto the resin from concentrated HNO₃, and desorbed with 0.1 M HCl while keeping the Pu adsorbed. The on-column reduction of Pu(IV) to Pu(III) with 0.02 M TiCl₃ facilitated the complete desorption of Pu. Interferences (e.g. Ca²⁺, Fe³⁺) were washed off from the resin bed with excess HNO₃. Using NdF₃, micro-precipitates of the separated isotopes were prepared for analysis by both AMS and alpha spectrometry. The recovery was 97.7 ± 5.3% and 95.5 ± 4.6% for ²⁴¹Am and ²⁴²Pu respectively in reagents without a matrix. The recoveries of the same isotopes were 99.1 ± 6.0 and 96.8 ± 5.3% respectively in garden soil. The robustness of the method was validated using certified reference materials (IAEA 384 and IAEA 385). The measurements agree with the certified values over a range of about 1–100 Bq kg⁻¹. The single column separation of Pu and Am saves reagents, separation time, and cost.

  4. Semi-targeted analysis of metabolites using capillary-flow ion chromatography coupled to high-resolution mass spectrometry.

    Science.gov (United States)

    Burgess, Karl; Creek, Darren; Dewsbury, Paul; Cook, Ken; Barrett, Michael P

    2011-11-30

    This work describes a novel application of capillary-flow ion chromatography mass spectrometry for metabolomic analysis, and comparison of the technique to octadecyl silica and hydrophilic interaction chromatography (HILIC)-based mass spectrometry. While liquid chromatography/mass spectrometry (LC/MS) is rapidly becoming the standard technique for metabolomic analysis, metabolomic samples are extremely heterogeneous, leading to a requirement for multiple methods of analysis and separation techniques to perform a 'global' metabolomic analysis. While C18 is suitable for hydrophobic metabolites and has been used extensively in pharmaceutical drug metabolism studies, HILIC is, in general, efficient at separating polar metabolites. Phosphorylated species and organic acids are challenging to analyse and effectively quantitate on both systems. There is therefore a requirement for an MS-compatible analytical technique that can separate negatively charged compounds, such as ion-exchange chromatography. Evaluation of capillary flow ion chromatography with electrolytic suppression was performed on a library of metabolite standards and was shown to effectively separate organic acids and sugar di- and tri-phosphates. Limits of detection for these compounds range from 0.01 to 100 pmol on-column. Application of capillary ion chromatography to a comparative analysis of energy metabolism in procyclic forms of the parasitic protozoan Trypanosoma brucei where cells were grown on glucose or proline as a carbon source was demonstrated to be more effective than HILIC for detection of the organic acids that comprise glucose central metabolism and the tricarboxylic acid (TCA) cycle.

  5. Liquid chromatography tandem mass spectrometry for measuring ¹³C-labeling in intermediates of the glycolysis and pentose phosphate pathway.

    Science.gov (United States)

    Cocuron, Jean-Christophe; Alonso, Ana Paula

    2014-01-01

    This chapter describes a procedure to analyze (13)C-labeled phosphorylated compounds by liquid chromatography tandem mass spectrometry. Phosphorylated compounds, intermediaries of the glycolysis and pentose phosphate pathway, are separated by anion exchange chromatography and their isotopic labeling is determined by mass spectrometry. A sensitivity in the fmole range is achieved using scheduled multiple reaction monitoring mode.

  6. Isolation of Pu-isotopes from environmental samples using ion chromatography for accelerator mass spectrometry and alpha spectrometry.

    Science.gov (United States)

    Chamizo, E; Jiménez-Ramos, M C; Wacker, L; Vioque, I; Calleja, A; García-León, M; García-Tenorio, R

    2008-01-14

    A radiochemical method for the isolation of plutonium-isotopes from environmental samples, based on the use of specific extraction chromatography resins for actinides (TEVA), Eichrom Industries, Inc.), has been set up in our laboratory and optimised for their posterior determination by alpha spectrometry (AS) or accelerator mass spectrometry (AMS). The proposed radiochemical method has replaced in our lab a well-established one based on the use of a relatively un-specific anion-exchange resin (AG) 1X8, Bio-rad Laboratories, Inc.), because it is clearly less time consuming, reduces the amounts and molarities of acid wastes produced, and reproducibly gives high radiochemical yields. In order to check the reliability of the proposed radiochemical method for the determination of plutonium-isotopes in different environmental matrixes, twin aliquots of a set of samples were prepared with TEVA and with AG 1X8 resins and measured by AS. Some samples prepared with TEVA resins were measured as well by AMS. As it is shown in the text, there is a comfortable agreement between AS and AMS, which adequately validates the method.

  7. Isolation of Pu-isotopes from environmental samples using ion chromatography for accelerator mass spectrometry and alpha spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Chamizo, E. [Centro Nacional de Aceleradores (CNA), Avda. Thomas A. Edison, 41092 Sevilla (Spain)], E-mail: elechacal@alum.us.es; Jimenez-Ramos, M.C. [Applied Nuclear Physics Group, University of Sevilla, P.O. Box 1065, 41080 Sevilla (Spain); Wacker, L. [Institute of Particle Physics, ETH Hoenggerberg, CH-8093 Zuerich (Switzerland); Vioque, I.; Calleja, A. [Applied Nuclear Physics Group, University of Sevilla, P.O. Box 1065, 41080 Sevilla (Spain); Garcia-Leon, M. [Centro Nacional de Aceleradores (CNA), Avda. Thomas A. Edison, 41092 Sevilla (Spain); Applied Nuclear Physics Group, University of Sevilla, P.O. Box 1065, 41080 Sevilla (Spain); Garcia-Tenorio, R. [Applied Nuclear Physics Group, University of Sevilla, P.O. Box 1065, 41080 Sevilla (Spain)

    2008-01-14

    A radiochemical method for the isolation of plutonium-isotopes from environmental samples, based on the use of specific extraction chromatography resins for actinides (TEVA, Eichrom Industries, Inc.), has been set up in our laboratory and optimised for their posterior determination by alpha spectrometry (AS) or accelerator mass spectrometry (AMS). The proposed radiochemical method has replaced in our lab a well-established one based on the use of a relatively un-specific anion-exchange resin (AG 1X8, Bio-rad Laboratories, Inc.), because it is clearly less time consuming, reduces the amounts and molarities of acid wastes produced, and reproducibly gives high radiochemical yields. In order to check the reliability of the proposed radiochemical method for the determination of plutonium-isotopes in different environmental matrixes, twin aliquots of a set of samples were prepared with TEVA and with AG 1X8 resins and measured by AS. Some samples prepared with TEVA resins were measured as well by AMS. As it is shown in the text, there is a comfortable agreement between AS and AMS, which adequately validates the method.

  8. Suspended trapping gas chromatography I fourier transform mass spectrometry for analysis of complex organic mixtures.

    Science.gov (United States)

    Hogan, J D; Laude, D A

    1990-11-01

    The superior sensitivity , dynamic range, and mass measurement accuracy of suspended trapping pulse sequences for gas chromatography combined with Fourier transform mass spectrometry (GC/FTMS) separations of complex organic mixtures is demonstrated. By combining intense ionization conditions with a suspended trapping event prior to detection the working range of the trapped ion cell is increased by 10(3) . Improved detection limits are shown for the GC/FTMS separation of a peppermint oil, with the suspended trapping total ion chromatogram yielding 28 peaks, compared with 15 with a conventional trapping pulse sequence. A fivefold to fifteenfold improvement in signal-to-noise for suspended trapping measurements is also demonstrated with comparison spectra from separations of an unleaded gasoline sample. Suspended trapping spectra show little mass discrimination when an external ion reservoir is used, and chromatographic peak heights differ from conventional spectra by less than 30% if the initial ion population is within the space charge limit of the cell. Finally, average wide band mass measurement errors for components differing in concentration by several orders of magnitude are improved by a factor of 6 to 20 with suspended trapping compared with conventional trapping . For example, average errors of 8.7 ppm are obtained for a suspended trapping GC/FTMS separation of peppermint oil from a single calibration table in which the analysis is perfonned in the absence of calibrant.

  9. Simultaneous determination of estrogens and progestogens in honey using high performance liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    This work describes the development and validation of a method for the simultaneous determination of 13 estrogens and progestogens in honey by high performance liquid chromatography-tandem mass spectrometry. The target compounds were preconcentrated by solid phase extraction. Pretreatment variables ...

  10. ANALYSIS OF ARTEMISININ AND RELATED SESQUITERPENOIDS FROM ARTEMISIA-ANNUA L BY COMBINED GAS-CHROMATOGRAPHY MASS-SPECTROMETRY

    NARCIS (Netherlands)

    WOERDENBAG, HJ; PRAS, N; BOS, R; VISSER, JF; HENDRIKS, H; MALINGRE, TM

    1991-01-01

    The sesquiterpenoid artemisinin (3) and its biosynthetic precursors arteannuic acid (1), arteannuin B (2) and artemisitene (4) can be separated and identified by combined gas chromatography/mass spectrometry both as a mixture of reference standards as well as in extracts of Artemisia annua L. From t

  11. Liquid chromatography-tandem mass spectrometry assay for the quantification of free and total sialic acid in human cerebrospinal fluid.

    NARCIS (Netherlands)

    Ham, M. van der; Koning, T.J. de; Lefeber, D.J.; Fleer, A.; Prinsen, B.H.; Sain-van der Velden, M.G. de

    2010-01-01

    BACKGROUND: Analysis of sialic acid (SA) metabolites in cerebrospinal fluid (CSF) is important for clinical diagnosis. In the present study, a high-performance liquid chromatography-tandem mass spectrometry (HPLC/MS/MS) method for free sialic acid (FSA) and total sialic acid (TSA) in human CSF was v

  12. An Advanced Analytical Chemistry Experiment Using Gas Chromatography-Mass Spectrometry, MATLAB, and Chemometrics to Predict Biodiesel Blend Percent Composition

    Science.gov (United States)

    Pierce, Karisa M.; Schale, Stephen P.; Le, Trang M.; Larson, Joel C.

    2011-01-01

    We present a laboratory experiment for an advanced analytical chemistry course where we first focus on the chemometric technique partial least-squares (PLS) analysis applied to one-dimensional (1D) total-ion-current gas chromatography-mass spectrometry (GC-TIC) separations of biodiesel blends. Then, we focus on n-way PLS (n-PLS) applied to…

  13. High performance liquid chromatography-mass spectrometry analysis of high antioxidant australian fruits with antiproliferative activity against cancer cells

    Directory of Open Access Journals (Sweden)

    Joseph Sirdaarta

    2016-01-01

    Abbreviations used: DPPH: di (phenyl- (2,4,6-trinitrophenyl iminoazanium, HPLC: High-performance liquid chromatography, IC50: The concentration required to inhibit by 50%, LC50: The concentration required to achieve 50% mortality, MS: Mass spectrometry. Ian Edwin Cock

  14. Elucidation and identification of amino acid containing membrane lipids using liquid chromatography/high-resolution mass spectrometry

    NARCIS (Netherlands)

    Moore, E.K.; Hopmans, E.C.; Rijpstra, W.I.C.; Villanueva, L.; Sinninghe Damsté, J.S.

    2016-01-01

    RATIONALE: Intact polar lipids (IPLs) are the building blocks of cell membranes, and amino acid containing IPLs havebeen observed to be involved in response to changing environmental conditions in various species of bacteri a. High-performance liquid chromatography/mass spectrometry (HPLC/MS) has be

  15. Molecular analysis of intact preen waxes of Calidris canutus (Aves : Scolopacidae) by gas chromatography/mass spectrometry

    NARCIS (Netherlands)

    Dekker, MHA; Piersma, T; Damste, JSS; Dekker, Marlèn H.A.; Sinninghe Damsté, Jaap S.

    2000-01-01

    The intact preen wax esters of the red knot Calidris canutus were studied with gas chromatography/mass spectrometry (GC/MS) and GC/MS/MS. In this latter technique, transitions from the molecular ion to fragment ions representing the fatty acid moiety of the wax esters were measured, providing additi

  16. ANALYSIS OF TRACE-LEVEL ORGANIC COMBUSTION PROCESS EMISSIONS USING NOVEL MULTIDIMENSIONAL GAS CHROMATOGRAPHY-MASS SPECTROMETRY PROCEDURES

    Science.gov (United States)

    The paper discusses the analysis of trace-level organic combustion process emissions using novel multidimensional gas chromatography-mass spectrometry (MDGC-MS) procedures. It outlines the application of the technique through the analyses of various incinerator effluent and produ...

  17. Structural Elucidation of DNA-Protein Crosslinks Using Reductive Desulfurization and Liquid Chromatography-Tandem Mass Spectrometry

    OpenAIRE

    Wickramaratne, Susith; Tretyakova, Natalia Y.

    2014-01-01

    Structural characterization of DNA-protein crosslinks involving cysteine using reductive desulfurization in combination with liquid chromatography-tandem mass spectrometry is highlighted. The novel approach was used to identify hydrolytically stable DNA-protein lesions involving alkylguanine DNA alkyltransferase (AGT).

  18. Determination of olanzapine in whole blood using simple protein precipitation and liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Marie Katrine Klose; Johansen, Sys Stybe

    2009-01-01

    A simple, sensitive, and reproducible liquid chromatography-tandem mass spectrometry method has been developed and validated for the quantification of the antipsychotic drug olanzapine in whole blood using dibenzepine as internal standard (IS). After acidic methanol-induced protein precipitation...

  19. Direct detection of Mycobacterium tuberculosis in sputum using combined solid phase extraction-gas chromatography-mass spectrometry

    NARCIS (Netherlands)

    Dang, N.A.; Mourão, M.; Kuijper, S.; Walters, E.; Janssen, H.-G.; Kolk, A.H.J.

    2015-01-01

    Recently, thermally-assisted hydrolysis and methylation followed by gas chromatography-mass spectrometry (THM-GC-MS) in combination with chemometrics has been used to develop a 20-compound model for fast differentiation of Mycobacterium tuberculosis (MTB) from Non-tuberculous mycobacteria (NTM) in b

  20. Hydrophilic interaction chromatography-mass spectrometry for anionic metabolic profiling of urine from antibiotic-treated rats

    NARCIS (Netherlands)

    Kok, Miranda G M; Swann, Jonathan R; Wilson, Ian D; Somsen, Govert W; de Jong, Gerhardus J

    2014-01-01

    Hydrophilic interaction chromatography-mass spectrometry (HILIC-MS) was used for anionic metabolic profiling of urine from antibiotic-treated rats to study microbial-host co-metabolism. Rats were treated with the antibiotics penicillin G and streptomycin sulfate for four or eight days and compared t

  1. Confirmation of synthetic glucocorticoids with liquid chromatography/mass spectrometry: Organization and results of an international interlaboratory comparison test

    NARCIS (Netherlands)

    Hauwe, O. van den; Campbell, K.; Crooks, S.R.H.; Schilt, R.; Peteghem, C.H. van

    2005-01-01

    Within the framework of a European Union (EU) research project entitled "Food Safety Screening: Synthetic Glucocorticoids (QLK1-1999-00122)," an international interlaboratory ring test was organized to compare and evaluate different liquid chromatography/mass spectrometry (LC/MS) confirmatory method

  2. Determination of kava lactones in food supplements by liquid chromatography-atmospheric pressure chemical ionisation tandem mass spectrometry

    NARCIS (Netherlands)

    Bobeldijk, I.; Boonzaaijer, G.; Spies-Faber, E.J.; Vaes, W.H.J.

    2005-01-01

    Reversed-phase liquid chromatography and detection with atmospheric pressure chemical ionisation tandem mass spectrometry was used for the determination of kava extracts in herbal mixtures. One percent of kava extract can be detected, corresponding to approximately 0.05-0.2 mg/g of the individual ka

  3. Comparative urine analysis by liquid chromatography-mass spectrometry and multivariate statistics : Method development, evaluation, and application to proteinuria

    NARCIS (Netherlands)

    Kemperman, Ramses F. J.; Horvatovich, Peter L.; Hoekman, Berend; Reijmers, Theo H.; Muskiet, Frits A. J.; Bischoff, Rainer

    2007-01-01

    We describe a platform for the comparative profiling of urine using reversed-phase liquid chromatography-mass spectrometry (LC-MS) and multivariate statistical data analysis. Urinary compounds were separated by gradient elution and subsequently detected by electrospray Ion-Trap MS. The lower limit o

  4. Simultaneous Determination of 25 Common Pharmaceuticals in Whole Blood Using Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Marie Katrine Klose; Johansen, Sys Stybe

    2012-01-01

    An ultra-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of 25 common pharmaceuticals in whole blood. The selected pharmaceuticals represent the most frequently detected drugs in our forensic laboratory with basic properties...

  5. Advantages of Atmospheric Pressure Chemical Ionization in Gas Chromatography Tandem Mass Spectrometry: Pyrethroid Insecticides as a Case Study

    NARCIS (Netherlands)

    Portolés, T.; Mol, J.G.J.; Sancho, J.V.; Hernández, F.

    2012-01-01

    Gas chromatography coupled to mass spectrometry (GC/MS) has been extensively applied for determination of volatile, nonpolar, compounds in many applied fields like food safety, environment, or toxicology. The wide majority of methods reported use electron ionization (EI), which may result in extensi

  6. Introducing Students to Gas Chromatography-Mass Spectrometry Analysis and Determination of Kerosene Components in a Complex Mixture

    Science.gov (United States)

    Pacot, Giselle Mae M.; Lee, Lyn May; Chin, Sung-Tong; Marriott, Philip J.

    2016-01-01

    Gas chromatography-mass spectrometry (GC-MS) and GC-tandem MS (GC-MS/MS) are useful in many separation and characterization procedures. GC-MS is now a common tool in industry and research, and increasingly, GC-MS/MS is applied to the measurement of trace components in complex mixtures. This report describes an upper-level undergraduate experiment…

  7. Direct analysis of intact glycidyl fatty acid esters in edible oils using gas chromatography-mass spectrometry

    NARCIS (Netherlands)

    van Steenbergen, H.; Hrnčiřík, K.; Ermacora, A.; de Koning, S.; Janssen, H.-G.

    2013-01-01

    Glycidyl esters (GE), fatty acid esters of glycidol, are process contaminants formed during edible oil processing. A novel direct method for the determination of intact GE in oils and fats based on gas chromatography-mass spectrometry (GC-MS) is presented. The method consists of a simple extraction

  8. Determination of BROMATE AT PARTS-PER-TRILLION LEVELS BY GAS CHROMATOGRAPHY-MASS SPECTROMETRY WITH NEGATIVE CHEMICAL IONIZATION

    Science.gov (United States)

    The ozonation of bromide-containing source waters produces bromate as a class 2B carcinogenic disinfection by-product. The present work describes the determination of bromate by gas chromatography-negative chemical ionization mass spectrometry (GC-NCIMS) following a bromate react...

  9. Thin-Layer Chromatography/Desorption Electrospray Ionization Mass Spectrometry: Investigation of Goldenseal Alkaloids

    Energy Technology Data Exchange (ETDEWEB)

    Van Berkel, Gary J [ORNL; Tomkins, Bruce A [ORNL; Kertesz, Vilmos [ORNL

    2007-01-01

    Desorption electrospray ionization mass spectrometry was investigated as a means to qualitatively identify and to quantify analytes directly from developed normal-phase thin layer chromatography plates. The atmospheric sampling capillary of a commercial ion trap mass spectrometer was extended to permit sampling and ionization of analytes in bands separated on intact TLC plates (up to 10 cm x 10 cm). A surface positioning software package and the appropriate hardware enabled computer-controlled surface scanning along the length of development lanes or at fixed RF value across the plates versus the stationary desorption electrospray emitter. Goldenseal (Hydrastis canadensis) and related alkaloids and commercial dietary supplements were used as standards and samples. Alkaloid standards and samples were spotted and separated on aluminum- or glass-backed plates using established literature methods. The mass spectral signal levels as a function of desorption spray solvent were investigated with acetonitrile proving superior to methanol. The detection levels (ca. 5 ng each or 14 -28 pmol) in mass spectral full scan mode were determined statistically from the calibration curves (2.5 - 100 pmol) for the standards berberine, palmatine and hydrastinine spotted as a mixture and separated on the plates. Qualitative screening of the major alkaloids present in six different over-the-counter "goldenseal" dietary supplements was accomplished by obtaining full scan mass spectra during surface scans along the development lane in the direction of increasing RF value. In one sample, alkaloids were detected that strongly suggested the presence of at least one additional herb undeclared on the product label. These same data indicated the misidentification of one of the alkaloids in the TLC literature. Quantities of the alkaloids present in two of the samples determined using the mass spectral data were in reasonable agreement with the label values indicating the quantitative ability of

  10. Saccharomyces cerevisiae oxidative response evaluation by cyclic voltammetry and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Castro, Cristiana C; Gunning, Caitriona; Oliveira, Carla M; Couto, José A; Teixeira, José A; Martins, Rui C; Ferreira, António C Silva

    2012-07-25

    This study is focused on the evaluation of the impact of Saccharomyces cerevisiae metabolism in the profile of compounds with antioxidant capacity in a synthetic wine during fermentation. A bioanalytical pipeline, which allows for biological systems fingerprinting and sample classification by combining electrochemical features with biochemical background, is proposed. To achieve this objective, alcoholic fermentations of a minimal medium supplemented with phenolic acids were evaluated daily during 11 days, for electrochemical profile, phenolic acids, and the volatile fermentation fraction, using cyclic voltametry, high-performance liquid chromatography-diode array detection, and headspace/solid-phase microextraction/gas chromatography-mass spectrometry (target and nontarget approaches), respectively. It was found that acetic acid, 2-phenylethanol, and isoamyl acetate are compounds with a significative contribution for samples metabolic variability, and the electrochemical features demonstrated redox-potential changes throughout the alcoholic fermentations, showing at the end a similar pattern to normal wines. Moreover, S. cerevisiae had the capacity of producing chlorogenic acid in the supplemented medium fermentation from simple precursors present in the minimal medium.

  11. Liquid chromatography/mass spectrometry analysis of exhaled leukotriene B4 in asthmatic children

    Directory of Open Access Journals (Sweden)

    Barnes Peter J

    2005-10-01

    Full Text Available Abstract Background The role of leukotriene (LT B4, a potent inflammatory mediator, in atopic asthmatic and atopic nonasthmatic children is largely unknown. The lack of a gold standard technique for measuring LTB4 in exhaled breath condensate (EBC has hampered its quantitative assessment in this biological fluid. We sought to measure LTB4 in EBC in atopic asthmatic children and atopic nonasthmatic children. Exhaled nitric oxide (NO was measured as an independent marker of airway inflammation. Methods Fifteen healthy children, 20 atopic nonasthmatic children, 25 steroid-naïve atopic asthmatic children, and 22 atopic asthmatic children receiving inhaled corticosteroids were studied. The study design was of cross-sectional type. Exhaled LTB4 concentrations were measured using liquid chromatography/mass spectrometry-mass spectrometry (LC/MS/MS with a triple quadrupole mass spectrometer. Exhaled NO was measured by chemiluminescence with a single breath on-line method. LTB4 values were expressed as the total amount (in pg of eicosanoid expired in the 15-minute breath test. Kruskal-Wallis test was used to compare groups. Results Compared with healthy children [87.5 (82.5–102.5 pg, median and interquartile range], exhaled LTB4 was increased in steroid-naïve atopic asthmatic [255.1 (175.0–314.7 pg, p 4 than steroid-naïve asthmatics [125.0 (25.0–245.0 pg vs 255.1 (175.0–314.7 pg, p Conclusion In contrast to exhaled NO concentrations, exhaled LTB4 values are selectively elevated in steroid-naïve atopic asthmatic children, but not in atopic nonasthmatic children. Although placebo control studies are warranted, inhaled corticosteroids seem to reduce exhaled LTB4 in asthmatic children. LC/MS/MS analysis of exhaled LTB4 might provide a non-invasive, sensitive, and quantitative method for airway inflammation assessment in asthmatic children.

  12. Analysis of psilocybin and psilocin in Psilocybe subcubensis Guzmán by ion mobility spectrometry and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Keller, T; Schneider, A; Regenscheit, P; Dirnhofer, R; Rücker, T; Jaspers, J; Kisser, W

    1999-01-11

    A new method has been developed for the rapid analysis of psilocybin and/or psilocin in fungus material using ion mobility spectrometry. Quantitative analysis was performed by gas chromatography-mass spectrometry after a simple one-step extraction involving homogenization of the dried fruit bodies of fungi in chloroform and derivatization with MSTFA. The proposed methods resulted in rapid procedures useful in analyzing psychotropic fungi for psilocybin and psilocin.

  13. Rhamnolipid biosurfactant analysis using online turbulent flow chromatography-liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Behrens, Beate; Helmer, Patrick O; Tiso, Till; Blank, Lars M; Hayen, Heiko

    2016-09-23

    Rhamnolipids are biosurfactants produced by a variety of bacterial species that present a promising alternative to surfactants from petrochemical or oleochemical origin. The success of the fermentation is evaluated by subsequent qualitative and quantitative analysis. However, the sample preparation for high numbers of samples is often laborious and inefficient. In this study an online sample preparation is developed for the qualitative and quantitative analysis of rhamnolipids by LC-MS/MS. Online sample preparation is carried out on a TurboFlow Cyclone MAX column using turbulent flow chromatography. Sample preparation prior the analysis is minimized to a dilution and syringe filtration step leading to an instrumental analysis time of 33min. The limit of detection and the limit of quantification were 0.4ng and 0.6ng on column, respectively. Recovery of the main mono- and di-rhamnolipids from a fermentation sample was 102-104%. Additionally, the rhamnolipid biosynthetic precursors 3-hydroxy(alkanoyloxy)alkanoic acids (HAAs) are covered, albeit extraction is not quantitative (85-90%). The analysis of rhamnolipids from four different microbial species was in good agreement with previous reports. The presented method allows rapid and comprehensive analysis of rhamnolipids with minimal sample preparation directly from the fermentation broth. The application of complementary data-dependent MS/MS acquisition enables non-target screening of rhamnolipids.

  14. Comprehensive characterisation of flame retardants in textile furnishings by ambient high resolution mass spectrometry, gas chromatography-mass spectrometry and environmental forensic microscopy.

    Science.gov (United States)

    Ionas, Alin C; Ballesteros Gómez, Ana; Uchida, Natsuyo; Suzuki, Go; Kajiwara, Natsuko; Takata, Kyoko; Takigami, Hidetaka; Leonards, Pim E G; Covaci, Adrian

    2015-10-01

    The presence and levels of flame retardants (FRs), such as polybrominated diphenyl ethers (PBDEs) and organophosphate flame retardants (PFRs), was determined in textile home furnishings, such as carpets and curtains from stores in Belgium. A comprehensive characterisation of FRs in textile was done by ambient high resolution mass spectrometry (qualitative screening), gas chromatography-mass spectrometry (GC-MS) (quantitation), and environmental forensic microscopy (surface distribution). Ambient ionisation coupled to a time-of-flight (TOF) high resolution mass spectrometer (direct probe-TOF-MS) was investigated for the rapid screening of FRs. Direct probe-TOF-MS proved to be useful for a first screening step of textiles to detect FRs below the levels required to impart flame retardancy and to reduce, in this way, the number of samples for further quantitative analysis. Samples were analysed by GC-MS to confirm the results obtained by ambient mass spectrometry and to obtain quantitative information. The levels of PBDEs and PFRs were typically too low to impart flame retardancy. Only high levels of BDE-209 (11-18% by weight) were discovered and investigated in localised hotspots by employing forensic microscopy techniques. Most of the samples were made of polymeric materials known to be inherently flame retarded to some extent, so it is likely that other alternative and halogen-free FR treatments/solutions are preferred for the textiles on the Belgian market.

  15. Americium and plutonium separation by extraction chromatography for determination by accelerator mass spectrometry.

    Science.gov (United States)

    Kazi, Zakir H; Cornett, Jack R; Zhao, Xaiolei; Kieser, Liam

    2014-06-04

    A simple method was developed to separate Pu and Am using single column extraction chromatography employing N,N,N',N'-tetra-n-octyldiglycolamide (DGA) resin. Isotope dilution measurements of Am and Pu were performed using accelerator mass spectrometry (AMS) and alpha spectrometry. For maximum adsorption Pu was stabilized in the tetra valent oxidation state in 8M HNO3 with 0.05 M NaNO2 before loading the sample onto the resin. Am(III) was adsorbed also onto the resin from concentrated HNO3, and desorbed with 0.1 M HCl while keeping the Pu adsorbed. The on-column reduction of Pu(IV) to Pu(III) with 0.02 M TiCl3 facilitated the complete desorption of Pu. Interferences (e.g. Ca(2+), Fe(3+)) were washed off from the resin bed with excess HNO3. Using NdF3, micro-precipitates of the separated isotopes were prepared for analysis by both AMS and alpha spectrometry. The recovery was 97.7±5.3% and 95.5±4.6% for (241)Am and (242)Pu respectively in reagents without a matrix. The recoveries of the same isotopes were 99.1±6.0 and 96.8±5.3% respectively in garden soil. The robustness of the method was validated using certified reference materials (IAEA 384 and IAEA 385). The measurements agree with the certified values over a range of about 1-100 Bq kg(-1). The single column separation of Pu and Am saves reagents, separation time, and cost.

  16. Quantitation of ethyl glucuronide in serum & urine by gas chromatography - mass spectrometry

    Directory of Open Access Journals (Sweden)

    Priyamvada Sharma

    2015-01-01

    Full Text Available Background & objectives: Alcohol misuse has now become a serious public health problem and early intervention is important in minimizing the harm. Biochemical markers of recent and high levels of alcohol consumption can play an important role in providing feedback regarding the health consequences of alcohol misuse. Existing markers are not sensitive to recent consumption and in detecting early relapse. Ethyl glucuronide (EtG, a phase-II metabolite of ethanol is a promising marker of recent alcohol use and can be detected in body fluids. In this study an analytical technique for quantitation of EtG in body fluids using solid-phase extraction (SPE and gas chromatography (GC with mass spectrometric detection (MS was developed and validated. Methods: De-proteinization of serum and urine samples was done with perchloric acid and hydrochloric acid, respectively. Serum samples were passed through phospholipids removal cartridges for further clean up. EtG was isolated using amino propyl solid phase extraction columns. Chromatographic separation was achieved by gas chromatography with mass spectrometry. Results: Limit of detection and limit of quantitation were 50 and 150 ng/ml for urine and 80 and 210 ng/ml for serum, respectively. Signal to noise ratio was 3:1, mean absolute recovery was 80-85 per cent. Significant correlation was obtained between breath alcohol and serum EtG levels (r=0.853 and urine EtG and time since last abuse (r = -0.903 in clinical samples. Interpretation & conclusions: In the absence of other standardized techniques to quantitate EtG in biological samples, this gc0 - ms0 method was found to have high throughput and was sensitive and specific.

  17. [Determination of aflatoxins in cereals and oils by liquid chromatography-triple quadrupole tandem mass spectrometry].

    Science.gov (United States)

    Wang, Xiupin; Li, Peiwu; Yang, Yang; Zhang, Wen; Zhang, Qi; Fan, Sufang; Yu, Li; Wang, Lin; Chen, Xiaomei; Li, Ying; Jiang, Jun

    2011-06-01

    The high performance liquid chromatography (HPLC)-triple quadrupole tandem mass spectrometry was applied for the determination of the aflatoxins: B1 (AFB1), B2 (AFB2), G1 (AFG1) and G2 (AFG2), in cereals and oils. The samples were first extracted by ultrasonic method. The optimized conditions of ultrasonic extraction were as follows: temperature of 50 degrees C, extraction time of 3 min, methanol-water (containing 40 g/L NaCl) (80: 20, v/v) solution as the medium and a ratio of sample to solvent of 1 : 3 (g: mL). The extracts were then purified using an immunoaffinity column. The separation was performed on a C18 column with mobile phases of 10 mmol/L ammonium acetate and methanol in gradient elution. The sensitive detection of the four AFT compounds by electrospray ionization mass spectrometry (ESI-MS) was carried out in selected reaction monitoring (SRM) mode with aflatoxin M1 (AFM1) as the internal standard. Under the optimized conditions, the limits of detection of AFB1, AFB2, AFG1 and AFG2 were 0.002, 0.004, 0.004 and 0.012 microg/kg, respectively. The recoveries of aflatoxins in different spiked cereals and oils were in the range from 87% to 111%. The intra-day and inter-day precisions were not more than 6.7% and 5.6%, respectively. In comparison with the external standard method, this method can effectively inhibit the matrix effects, and greatly improve the accuracy.

  18. [Determination of aflatoxins in cashew by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Bi, Ruifeng; Fan, Zhixian; Fu, Meng

    2011-12-01

    A method for the determination of four aflatoxins in cashew using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed. The sample was extracted with methanol-water (8: 2, v/v) solution, followed by a cleanup procedure with Florisil column. The target compounds were eluted using 5 mL acetone-water-formic acid (96: 3.5:0.5, v/v/v) solution. The eluate was dried under N2, then dissolved in 1 mL methanol. Four aflatoxins were separated in MG C18 column (100 mm x 3.0 mm, 3 microm) adopting a gradient program within 15 min. A triple quadrupole mass spectrometry equipped with an electrospray ionization source operated in the positive ion mode was used to detect the aflatoxins. The good correlation coefficients (r2 > 0.997) of the four aflatoxins were obtained within their respective linear ranges. The limits of detection (S/N = 3) were between 0.009 microg/kg and 0.04 microg/kg, and the limits of quantification (S/N = 10) were between 0.03 microg/kg and 0.12 microg/kg. The recoveries were in a range of 63.0% -78.5% with the relative standard deviations (RSDs) varied from 2.8% to 9.1%. The validation results meet the requirements of trace assay. Matrix effects were estimated and the signal suppression/enhancement ranged from 88.8% to 99.4%. The results indicate that the developed method is simple, fast, accurate, and can be applied for the determination of fours aflatoxins in cashew.

  19. An empirical Bayes model using a competition score for metabolite identification in gas chromatography mass spectrometry

    Directory of Open Access Journals (Sweden)

    Kim Seongho

    2011-10-01

    Full Text Available Abstract Background Mass spectrometry (MS based metabolite profiling has been increasingly popular for scientific and biomedical studies, primarily due to recent technological development such as comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GCxGC/TOF-MS. Nevertheless, the identifications of metabolites from complex samples are subject to errors. Statistical/computational approaches to improve the accuracy of the identifications and false positive estimate are in great need. We propose an empirical Bayes model which accounts for a competing score in addition to the similarity score to tackle this problem. The competition score characterizes the propensity of a candidate metabolite of being matched to some spectrum based on the metabolite's similarity score with other spectra in the library searched against. The competition score allows the model to properly assess the evidence on the presence/absence status of a metabolite based on whether or not the metabolite is matched to some sample spectrum. Results With a mixture of metabolite standards, we demonstrated that our method has better identification accuracy than other four existing methods. Moreover, our method has reliable false discovery rate estimate. We also applied our method to the data collected from the plasma of a rat and identified some metabolites from the plasma under the control of false discovery rate. Conclusions We developed an empirical Bayes model for metabolite identification and validated the method through a mixture of metabolite standards and rat plasma. The results show that our hierarchical model improves identification accuracy as compared with methods that do not structurally model the involved variables. The improvement in identification accuracy is likely to facilitate downstream analysis such as peak alignment and biomarker identification. Raw data and result matrices can be found at http

  20. Analysis of daphnane orthoesters in poisonous Australian pimelea species by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Chow, Sharon; Fletcher, Mary T; McKenzie, Ross A

    2010-06-23

    Cattle grazing in arid rangelands of Australia suffer periodic extensive and serious poisoning by the plant species Pimelea trichostachya, P. simplex, and P. elongata. Pimelea poisoning (also known as St. George disease and Marree disease) has been attributed to the presence of the diterpenoid orthoester simplexin in these species. However, literature relating to previous studies is complicated by taxonomic revisions, and the presence of simplexin has not previously been verified in all currently recognized taxa capable of inducing pimelea poisoning syndrome, with no previous chemical studies of P. trichostachya (as currently classified) or P. simplex subsp. continua. We report here the isolation of simplexin from P. trichostachya and the development of a liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) method to measure simplexin concentrations in pimelea plant material. Simplexin was quantified by positive-ion atmospheric pressure chemical ionization (APCI) LC-MS/MS with selected reaction monitoring (SRM) of the m/z 533.3 > 253.3 transition. LC-MS/MS analysis of the four poisonous taxa P. trichostachya, P. elongata, P. simplex subsp. continua, and P. simplex subsp. simplex showed similar profiles with simplexin as the major diterpenoid ester component in all four taxa accompanied by varying amounts of related orthoesters. Similar analyses of P. decora, P. haematostachya, and P. microcephala also demonstrated the presence of simplexin in these species but at far lower concentrations, consistent with the limited reports of stock poisoning associated with these species. The less common, shrubby species P. penicillaris contained simplexin at up to 55 mg/kg dry weight and would be expected to cause poisoning if animals consumed sufficient plant material.

  1. Mass spectrometry

    DEFF Research Database (Denmark)

    Nyvang Hartmeyer, Gitte; Jensen, Anne Kvistholm; Böcher, Sidsel

    2010-01-01

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is currently being introduced for the rapid and accurate identification of bacteria. We describe 2 MALDI-TOF MS identification cases - 1 directly on spinal fluid and 1 on grown bacteria. Rapidly obtained r...

  2. Analysis of odour compounds from scented consumer products using gas chromatography-mass spectrometry and gas chromatography-olfactometry.

    Science.gov (United States)

    Bartsch, Jennifer; Uhde, Erik; Salthammer, Tunga

    2016-01-21

    Scented consumer products are being bought in increasing amounts and gaining more popularity. There is, however, relatively little information available about their ingredients, emissions and allergenic potential. Frequently, a mixture of different fragrance substances and not solely an individual substance contributes to the overall desired smell. The aim of this study was to investigate the odorous volatile organic compounds (OVOCs) in consumer products containing fragrances. Over 44 products were selected: various scented candles, printing products with different scent types and other products types particularly meant to be used indoors. Measurements were carried out in a desiccator. Air samples were collected on thermal desorption tubes to determine the released fragrance substances by means of gas chromatography-mass spectrometry (GC-MS). Moreover, gas chromatography-olfactometry (GC-O) was used to obtain sensory data and to ensure no important odorant was overlooked. Using both methods it was possible to distinguish between odour active and inactive compounds and subsequently to identify almost 300 different odorants across all scented products. Besides the advantage of differentiation, as the human nose is a very sensitive detector, GC-O was found to be a useful tool for detecting traces and chosen target compounds. One focus in this study lay on the 26 EU-regulated fragrance allergens to prove their relevance in scented consumer goods. In total, 18 of them were identified, with at least one substance being present in almost every product. Benzyl alcohol, cinnamaldehyde, citronellol, eugenol, linalool and limonene were the prevalently detected allergens. Particularly linalool and limonene were observed in over 50% of the products. In addition, eugenol appeared to be one of the most frequently detected compounds in trace-level concentrations in the candle emissions.

  3. Determination of alkyl amines in atmospheric aerosol particles: a comparison of gas chromatography-mass spectrometry and ion chromatography approaches

    Directory of Open Access Journals (Sweden)

    R.-J. Huang

    2014-03-01

    Full Text Available In recent years low molecular weight alkyl amines have been recognized to play an important role in particle formation and growth in the lower atmosphere. However, major uncertainties are associated with their atmospheric processes, sources and sinks, mostly due to the lack of ambient measurements and the difficulties in accurate quantification of alkyl amines at trace level. In this study, we present the evaluation and optimization of two analytical approaches, i.e., gas chromatography-mass spectrometry (GC-MS and ion chromatography (IC, for the determination of alkyl amines in aerosol particles. Alkyl amines were converted to carbamates through derivatization with isobutyl chloroformate for GC-MS determination. A set of parameters affecting the analytical performances of the GC-MS approach, including reagent amount, reaction time and pH value, was evaluated and optimized. The accuracy is 84.3–99.1%, and the limits of detection obtained are 1.8–3.9 pg. For the IC approach, a solid phase extraction (SPE column was used to separate alkyl amines from interfering cations before IC analysis. 1–2% (v/v of acetone (or 2–4% (v/v of acetonitrile was added to the eluent to improve the separation of alkyl amines on the IC column. The limits of detection obtained are 2.1–15.9 ng and the accuracy is 55.1–103.4%. The lower accuracy can be attributed to evaporation losses of amines during the sample concentration procedure. Measurements of ambient aerosol particle samples collected in Hong Kong show that the GC-MS approach is superior to the IC approach for the quantification of primary and secondary alkyl amines due to its lower detection limits and higher accuracy.

  4. Stress degradation study and structure characterization of oxidation degradation product of dexlansoprazole using liquid chromatography-mass spectrometry/time of flight, liquid chromatography-tandem mass spectrometry and nuclear magnetic resonance

    Institute of Scientific and Technical Information of China (English)

    Lakkireddy PRAKASH; M HIMAJA

    2016-01-01

    The present study deals with the forced degradation behavior of dexlansoprazole under International Conference on Harmonisation( ICH)prescribed stress conditions. The drug was found to be more labile under acid,base,neutral,oxidative hydrolysis and thermal stress,while it was moderately stable under photolytic conditions. The known and unknown degradation products were separated on a C-18 column using a stability-indicating method. Liquid chromatography-mass spectrometry( LC-MS)analysis was performed for all the deg-radation studies. Isolation and structure characterization of oxidation degradation products were executed using sophisticated tools,viz. preparative high performance liquid chromatography( HPLC),liquid chromatography-mass spectrometry/time of flight( LC-MS/TOF),liquid chromatography-tandem mass spectrometry( LC-MS/MS),and nuclear magnetic resonance( NMR). This study demonstrates an ample methodology of degradation studies and structure elucidation of unknown degradation products of dexlansoprazole,which helps in the development and stability study of active pharmaceutical ingredients and formulated products.

  5. Immunoaffinity purification of peptide hormones prior to liquid chromatography-mass spectrometry in doping controls.

    Science.gov (United States)

    Thomas, Andreas; Schänzer, Wilhelm; Delahaut, Philippe; Thevis, Mario

    2012-02-01

    For most peptide hormones prohibited in elite sports the concentrations in plasma or urine are very low (pg/mL). Accordingly, hyphenated purification and enrichment steps prior to mass spectrometric detection are required to obtain sufficient doping control assays. Immunoaffinity purification in combination with nano-scale liquid chromatography coupled to high resolution/high accuracy mass spectrometry was found to have the potential of providing the necessary sensitivity and unambiguous specificity to produce reliable results. With the presented methodology 12 prohibited peptides (porcine insulin, Novolog, Apidra, Lantus DesB30-32 metabolite, Humalog and human insulin, Synacthen (synthetic ACTH analogue), luteinizing hormone-releasing hormone (LH-RH), growth hormone releasing hormone (GH-RH(1-29)) and CJC-1295 (GH-RH analogue), LongR(3)-IGF-1 and IFG-1) were simultaneously purified from plasma/serum or urine. With limits of detection for each target compound ranging in the low pg/mL level (urine), the method enables the determination of urinary peptides at physiologically relevant concentrations. For each class of peptides an appropriate antibody and a respective internal standard was implemented ensuring robust analysis conditions. Due to the fast and simple sample preparation procedure (∼25 samples per day) and the fact that all materials are commercial available, the implementation of the methodology to laboratories from other analytical fields (forensics, pharmacokinetic sciences, etc.) is enabled.

  6. Determination of tolperisone in human plasma by liquid chromatography/tandem mass spectrometry for clinical application.

    Science.gov (United States)

    Choi, Chang-Ik; Park, Jung-In; Lee, Hye-In; Lee, Yun-Jeong; Jang, Choon-Gon; Bae, Jung-Woo; Lee, Seok-Yong

    2012-12-12

    We have developed and validated a simple, rapid, and sensitive liquid chromatography analytical method employing tandem mass spectrometry (LC-MS/MS) for the determination of tolperisone, a centrally acting muscle relaxant, in human plasma. After liquid-liquid extraction with methyl t-butyl ether, chromatographic separation of tolperisone was performed using a reversed-phase Luna C(18) column (2.0mm×50mm, 5μm particles) with a mobile phase of 10mM ammonium formate buffer (pH 3.5) - methanol (12:88, v/v) and quantified by tandem mass detection in ESI positive ion mode. The flow rate of the mobile phase was 250μL/min and the retention times of tolperisone and the internal standard (IS, dibucaine) were both 0.6min. The calibration curves were linear over a range of 0.5-300ng/mL (r>0.999). The lower limit of quantification, using 200μL human plasma, was 0.5ng/mL. The mean accuracy and precision for intra- and inter-day validation of tolperisone were within acceptable limits. The LC-MS/MS method reported here showed improved sensitivity for quantification of tolperisone in human plasma compared with previously described analytical methods. Lastly, the validated method was successfully applied to a pharmacokinetic study in humans.

  7. Discriminating Hodgdon Pyrodex(®) and Triple Seven(®) using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Routon, Benjamin J; Kocher, Brandon B; Goodpaster, John V

    2011-01-01

    Pyrodex(®) and Triple Seven(®) are black powder substitutes that often find use as fillers in improvised explosive devices, such as pipe bombs. These propellants have essentially the same overall appearance and oxidizers, but different fuels. For example, Pyrodex(®) contains sulfur, sodium benzoate, and dicyandiamide (DCDA), whereas Triple Seven(®) lacks sulfur but also contains 3-nitrobenzoic acid. In this method, intact particles and postblast solid residues were reacted with bis(trimethylsilyl)trifluoroacetamide + 1% trimethylchlorosilane in acetonitrile for 30 min at 60°C. The resultant trimethylsilyl derivatives of the organic fuels were then analyzed by gas chromatography-mass spectrometry. Each derivative was clearly resolved from other components, and high-quality mass spectra were obtained. In addition, characteristic fragments resulting from loss of a methyl radical from the molecular ion (m/z 163 for sulfur, m/z 171 for DCDA, m/z 179 for benzoic acid, and m/z 224 for nitrobenzoic acid) were able to be monitored.

  8. Liquid chromatography-tandem mass spectrometry for analysis of intestinal permeability of loperamide in physiological buffer.

    Directory of Open Access Journals (Sweden)

    Miriam S Rubelt

    Full Text Available Analysis of in vitro samples with high salt concentrations represents a major challenge for fast and specific quantification with liquid chromatography-tandem mass spectrometry (LC-MS/MS. To investigate the intestinal permeability of opioids in vitro employing the Ussing chamber technique, we developed and validated a fast, sensitive and selective method based on LC-MS/MS for the determination of loperamide in HEPES-buffered Ringer's solution. Chromatographic separation was achieved with an Atlantis dC18 column, 2.1 mm×20 mm, 3 µm particle size and a gradient consisting of methanol/0.1% formic acid and ammonium acetate. The flow rate was 0.7 ml/min, and the total run time was 3 min. For quantification, two mass transitions for loperamide and a deuterated internal standard (methadone-d(3 were used. The lower limit of loperamide quantification was 0.2 ng/ml. This new LC-MS/MS method can be used for the detection of loperamide in any experimental setup using HEPES-buffered Ringer's solution as a matrix compound.

  9. Determination of omeprazole and its metabolites in human plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Kanazawa, Hideko; Okada, Akiko; Matsushima, Yoshikazu; Yokota, Hiromitsu; Okubo, Shigeo; Mashige, Fumiko; Nakahara, Kazuhiko

    2002-03-08

    Omeprazole is a benzimidazole compound that acts as a proton-pump inhibitor. Because the metabolism of omeprazole is mainly catalyzed by cytochrome P-450 (CYP) 3A4 and CYP2C19. the genetic polymorphism of CYP2C19 could be of clinical concern in the treatment of acid-related diseases with omeprazole. Therefore, a reliable method for omeprazole phenotyping is desirable in clinical situations. This study has demonstrated the determination of omeprazole and its metabolites in human plasma by liquid chromatography-three-dimensional quadrupole mass spectrometry with a sonic spray ionization interface. The analytical column was YMC-Pack Pro C18(50x2.0 mm I.D.) using acetonitrile-50 mM ammonium acetate (pH 7.25) (1:4) at a flow-rate of 0.2 ml/min. The drift voltage was 30 V. The sampling aperture was heated at 110 degrees C and Shield temperature was 230 degrees C. In the mass spectrum, the molecular ions of omeprazole, hydroxyomeprazole and omeprazole sulfone were clearly observed as base peaks. This method is sufficiently sensitive and accurate for pharmacokinetic studies of omeprazol.

  10. Development of hemoglobin A1c certified reference material by liquid chromatography isotope dilution mass spectrometry.

    Science.gov (United States)

    Bi, Jiaming; Wu, Liqing; Yang, Bin; Yang, Yi; Wang, Jing

    2012-04-01

    We report the development of a National Institute of Metrology (NIM) hemoglobin A(1c) (HbA(1c)) certified reference material (CRM). Each CRM unit contains about 10 μL of hemoglobin. Both hemoglobin and glycated hemoglobin were quantitatively determined by high-performance liquid chromatography (HPLC)-isotope dilution mass spectrometry (IDMS) with synthesized VHLTPE and glycated VHLTPE as standards. The mass fraction of synthesized VHLTPE or glycated VHLTPE was also quantitatively determined by HPLC-IDMS with NIM amino acid CRMs as standards. The homogeneity and stability of the CRMs were examined with a commercial HbA(1c) analyzer based on the HPLC principle. Fifteen units were randomly selected for homogeneity examination, and statistical analysis showed there was no inhomogeneity. Examination of the stability showed that the CRM was stable for at least 6 months at -80 °C. Uncertainty components of the balance, amino acid purity, hydrolysis and proteolysis efficiency, method reproducibility, homogeneity, and stability were taken into consideration for uncertainty evaluation. The certified value of NIM HbA(1c) CRM was expressed as the ratio of HbA(1c) to total hemoglobin in moles, and was (9.6 ± 1.9)%. The CRM can be used as a calibration or validation standard for clinical diagnostics. It is expected to improve the comparability for HbA(1c) measurement in China.

  11. Determination of mycophenolic acid in human plasma by ultra performance liquid chromatography tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Vivek Upadhyay

    2014-06-01

    Full Text Available A simple, sensitive and high throughput ultra performance liquid chromatography tandem mass spectrometry method has been developed for the determination of mycophenolic acid in human plasma. The method involved simple protein precipitation of MPA along with its deuterated analog as an internal standard (IS from 50 µL of human plasma. The chromatographic analysis was done on Acquity UPLC C18 (100 mm×2.1 mm, 1.7 µm column under isocratic conditions using acetonitrile and 10 mM ammonium formate, pH 3.00 (75:25, v/v as the mobile phase. A triple quadrupole mass spectrometer operating in the positive ionization mode was used for quantitation. In-source conversion of mycophenolic glucuronide metabolite to the parent drug was selectively controlled by suitable optimization of cone voltage, cone gas flow and desolvation temperature. The method was validated over a wide concentration range of 15–15000 ng/mL. The mean extraction recovery for the analyte and IS was >95%. Matrix effect expressed as matrix factors ranged from 0.97 to 1.02. The method was successfully applied to support a bioequivalence study of 500 mg mycophenolate mofetil tablet in 72 healthy subjects.

  12. Liquid chromatography/tandem mass spectrometry assay for the quantification of troxerutin in human plasma.

    Science.gov (United States)

    Liu, Fei; Xu, Yu; Rui, Lei; Gao, Shu; Dong, Haijun; Guo, Qingxiang

    2006-01-01

    A simple, rapid, sensitive and specific liquid chromatography/tandem mass spectrometry method was developed and validated to quantify troxerutin in human plasma. The analyte and rutin, used as the internal standard, were analyzed on a Phenomenex Synergi Fusion RP column interfaced with a triple-quadrupole tandem mass spectrometer using positive electrospray ionization. Acetonitrile/water (20:80 v/v) was used as the isocratic mobile phase, with 0.1% formic acid in water. A simple sample preparation method of protein precipitation with perchloric acid was employed. The assay was linear over the concentration range 31.25-4000 pg/mL. Correlation coefficients generated by linear regression with a 1/x(2) weighting factor ranged from 0.9991 to 0.9996. The intra- and inter-day precision over the entire concentration range were less than 12.28%. The method was successfully applied to a pharmacokinetic study after oral administration of a 300 mg troxerutin drop pill to 18 healthy volunteers.

  13. Advances in liquid chromatography-high-resolution mass spectrometry for quantitative and qualitative environmental analysis.

    Science.gov (United States)

    Aceña, Jaume; Stampachiacchiere, Serena; Pérez, Sandra; Barceló, Damià

    2015-08-01

    This review summarizes the advances in environmental analysis by liquid chromatography-high-resolution mass spectrometry (LC-HRMS) during the last decade and discusses different aspects of their application. LC-HRMS has become a powerful tool for simultaneous quantitative and qualitative analysis of organic pollutants, enabling their quantitation and the search for metabolites and transformation products or the detection of unknown compounds. LC-HRMS provides more information than low-resolution (LR) MS for each sample because it can accurately determine the mass of the molecular ion and its fragment ions if it can be used for MS-MS. Another advantage is that the data can be processed using either target analysis, suspect screening, retrospective analysis, or non-target screening. With the growing popularity and acceptance of HRMS analysis, current guidelines for compound confirmation need to be revised for quantitative and qualitative purposes. Furthermore, new commercial software and user-built libraries are required to mine data in an efficient and comprehensive way. The scope of this critical review is not to provide a comprehensive overview of the many studies performed with LC-HRMS in the field of environmental analysis, but to reveal its advantages and limitations using different workflows.

  14. Determination of mycophenolic acid in human plasma by ultra performance liquid chromatography tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Vivek Upadhyay; Vikas Trivedi; Gaurang Shah; Manish Yadav; Pranav S. Shrivastav

    2014-01-01

    A simple, sensitive and high throughput ultra performance liquid chromatography tandem mass spectrometry method has been developed for the determination of mycophenolic acid in human plasma. The method involved simple protein precipitation of MPA along with its deuterated analog as an internal standard (IS) from 50 mL of human plasma. The chromatographic analysis was done on Acquity UPLC C18 (100mm*2.1mm,1.7mm) column under isocratic conditions using acetonitrile and 10 mM ammonium formate, pH 3.00 (75:25, v/v) as the mobile phase. A triple quadrupole mass spectrometer operating in the positive ionization mode was used for quantitation. In-source conversion of mycophenolic glucuronide metabolite to the parent drug was selectively controlled by suitable optimization of cone voltage, cone gas flow and desolvation temperature. The method was validated over a wide concentration range of 15–15000 ng/mL. The mean extraction recovery for the analyte and IS was 495%. Matrix effect expressed as matrix factors ranged from 0.97 to 1.02. The method was successfully applied to support a bioequivalence study of 500 mg mycophenolate mofetil tablet in 72 healthy subjects.

  15. Determination of ortho-phenylphenol in human urine by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Bartels, M J; Brzak, K A; Bormett, G A

    1997-12-05

    A sensitive gas chromatographic-mass spectrometric method was developed to quantitate total o-phenylphenol (OPP) (free plus conjugates) in human urine. Conjugates of OPP were acid-hydrolyzed to free OPP, derivatized to the pentafluorobenzoyl ester derivative and analyzed via negative-ion chemical ionization gas chromatography-mass spectrometry. Two stable isotope analogs of OPP were shown to be suitable as internal standards for this method (D2-phenol ring, 13C6-phenyl ring). A synthetic method is presented for the preparation of the D2-OPP internal standard. The 13C6-OPP analog was also shown to be useful as an alternate test material for laboratory-based exposure studies. The limit of quantitation for this method was 1 ng OPP/ml urine. Calibration curves were linear for the analyte over the concentration range of 0.5-1117 ng OPP/ml urine. Relative recovery of OPP from urine ranged from 97.0 to 104.7%. Low levels of OPP (mean=6+/-7 ng/ml; n=22) were found in control human urine samples. The method was validated with urine samples obtained from human volunteers undergoing a dermal exposure study with 12C-/13C6-/14C-OPP. This method was developed to aid in assessments of human exposure to OPP during a variety of uses of the compound.

  16. Determination of moxonidine in human plasma by liquid chromatography-electrospray ionisation-mass spectrometry.

    Science.gov (United States)

    Zhao, Luhua; Ding, Li; Wei, Xin

    2006-01-23

    A sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and quantification of moxonidine in human plasma. After the addition of clonidine-HCl, the internal standard (IS) and sodium hydrogen carbonate, plasma samples were extracted using 5 mL ethyl acetate. The compounds were separated on a Lichrospher ODS (5 microm, 250 mm x 4.6 mm) column using an elution system of 10 mmol/L ammonium acetate buffer-methanol (20:80 v/v) as the mobile phase. Analytes were determined using electrospary ionization in a single quadrupole mass spectrometer. LC-ESI-MS was performed in the selected-ion monitoring (SIM) mode using target ions at m/z: 242.2 for moxonidine and m/z: 230.1 for the IS. The method has shown to be sensitive and specific by testing six different blank plasma batches. Linearity was established for the range of concentrations 0.01976-9.88 ng/mL with a coefficient of correlation (r) of 0.9999. The lower limit of quantification (LOQ) was identifiable and reproducible at 0.01976 ng/mL. The method has been successfully applied to study the pharmacokinetics of moxonidine in healthy male Chinese volunteers.

  17. Deciphering chemical interactions between Glycyrrhizae Radix and Coptidis Rhizoma by liquid chromatography with transformed multiple reaction monitoring mass spectrometry.

    Science.gov (United States)

    Li, Zhenhao; Liu, Ting; Liao, Jie; Ai, Ni; Fan, Xiaohui; Cheng, Yiyu

    2017-01-18

    In this study, we propose an integrated strategy for the efficient identification and quantification of herbal constituents using liquid chromatography with mass spectrometry. First, liquid chromatography with quadrupole time-of-flight mass spectrometry was employed for the chemical profiling of herbs, where a targeted following nontargeted approach was developed to detect trace constituents by using structural correlations and extracted ion chromatograms. Next, ion pairs and parameters of MS(2) of quadrupole time-of-flight mass spectrometry were selected to design multiple reaction monitoring transitions for the identified compounds on liquid chromatography with triple quadrupole mass spectrometry. The relative concentration of each constituent was then calculated using a semiquantitative calibration curve. The proposed strategy was applied in a study of chemical interactions between Glycyrrhizae Radix and Coptidis Rhizoma. A total of 140 compounds were identified or tentatively characterized from the herbs, 132 of which were relatively quantified. The visualized quantitative results clearly showed codecoction produced significant constituent concentration variations especially for those with a low polarity. The case study also indicated that the present methodology could provide a reliable, accurate, and labor-saving solution for chemical studies of herbal medicines.

  18. Analysis of perfluoroalkyl substances in cord blood by turbulent flow chromatography coupled to tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Llorca, Marta; Perez, Francisca [Department of Environmental Chemistry, IDAEA-CSIC, Barcelona (Spain); Farre, Marinella, E-mail: mfuqam@cid.csic.es [Department of Environmental Chemistry, IDAEA-CSIC, Barcelona (Spain); Agramunt, Silvia [Centre for Research in Environmental Epidemiology (CREAL), Barcelona (Spain); IMIM (Hospital del Mar Research Institute), Barcelona (Spain); Kogevinas, Manolis [Centre for Research in Environmental Epidemiology (CREAL), Barcelona (Spain); IMIM (Hospital del Mar Research Institute), Barcelona (Spain); CIBER Epidemiologia y Salud Publica (CIBERESP), Barcelona (Spain); National School of Public Health, Athens (Greece); Barcelo, Damia [Department of Environmental Chemistry, IDAEA-CSIC, Barcelona (Spain); Catalan Institute for Water Research (ICRA), Girona (Spain); King Saud University, Riyadh (Saudi Arabia)

    2012-09-01

    A fast on-line analytical method based on turbulent flow chromatography (TFC) in combination with tandem mass spectrometry has been applied for the first time for the analysis of eighteen perfluoroalkyl substances (PFASs), in cord blood. A simple and rapid sample pre-treatment was optimised consisting on protein precipitation of 100 {mu}L of sample with acetonitrile (1:1) followed by centrifugation during 10 min. The method was adapted to be sensitive enough and robust with minimum sample injection volume requirements (20 {mu}L). The optimised methodology presented method limits of detection (MLOD) between 0.031 and 0.76 {mu}g/L, detection capabilities (CC{alpha}) in the range between 0.005 and 0.99 {mu}g/L and decision limits (CC{beta}) ranging from 0.006 to 1.16 {mu}g/L. The recoveries in blank blood were calculated by spiking experiments with a mixture of 18 PFASs and established between 70 and 126% for most of compounds. Isotopic dilution was carried out for quantification of selected analytes. In-house validation of this new approach was carried out according to the requirements in the 2002/657/EC Decision. Finally the good applicability of this new approach was proved by the analysis of 60 cord blood samples from two different Mediterranean cities, Barcelona (Spain) and Heraklion (Greece). Ions perfluorohexanesulfonate (PFHxS) and perfluorooctanesulfonate (PFOS) were found at highest concentration and the more frequently compounds were PFHxS, PFOS and perfluorooctanoic acid (PFOA). The newly developed method proved to be suitable for large-scale epidemiologic studies, and to the data on PFASs exposure during pregnancy. -- Highlights: Black-Right-Pointing-Pointer An on-line method has been developed for the analysis of 18 perfluoroalkyl substances. Black-Right-Pointing-Pointer The method is based on turbulent flow chromatography tandem mass spectrometry. Black-Right-Pointing-Pointer The method was applied in 60 cord blood samples from 2 Mediterranean cities

  19. Determination of seven pyrethroids and six pyrethrins in water by liquid chromatography/mass spectrometry

    Science.gov (United States)

    ccanccapa, alexander; Masia, Ana; Pico, Yolanda

    2016-04-01

    Pyrethroids are the synthetic analogues of pyrethrins which were developed as pesticides from the extracts of dried and powdered flower heads of Chrysanthemum cinerariaefolium. They are increasingly used in agriculture due to their broad biological activity and slow development of pest resistance. Contamination of fresh-water ecosystems appears either because of the direct discharge of industrial and agricultural effluents or as a result of effluents from sewage treatment works; residues can thus accumulate in the surrounding biosphere [1, 2]. These substances, mostly determined by gas chromatography mass spectrometry (GC-MS) can be difficult to analyse due to their volatility and degradability. The purpose of this study is, as an alternative, to develop a fast and sensitive multi-residue method for the target analysis of 7 pyrethroids and the 6 natural pyrethrins currently used in water samples by liquid chromatography tandem mass spectrometry (LC-MS/MS). The compounds included in the study were acrinathrin, etofenprox, cyfluthrin, esfenvalerate, cyhalothrin, cypermethrin and flumethrin as pyrethroids and a commercial mix of pyrethrins containing Cinerin I, Jasmolin I, pyrethrin I, cinerin II, jasmolin II, pyrethrins II in different percentages. As a preliminary step, the ionization and fragmentation of the compounds were optimized injecting individual solutions of each analyte at 10 ppm in the system, using a gradient elution profile of water-methanol both with 10 mM ammonium formate. The ESI conditions were: capillary voltage 4000 V, nebulizer15 psi, source temperature 300◦C and gas flow 10 L min-1. [M+H]+, [M+Na]+ ,[M+NH3]+ ,[M+NH4+]+ were tested as precursor ions. The most intense signal was for ammonium adduct for all compounds. The optimal fragmentor range for product ions were between 20 to 80 ev and the collision energy ranged between 5 to 86 ev. The efficiency of the method was tested in water samples from Turia River without any known exposure to

  20. Multivariate analysis of progressive thermal desorption coupled gas chromatography-mass spectrometry.

    Energy Technology Data Exchange (ETDEWEB)

    Van Benthem, Mark Hilary; Mowry, Curtis Dale; Kotula, Paul Gabriel; Borek, Theodore Thaddeus, III

    2010-09-01

    Thermal decomposition of poly dimethyl siloxane compounds, Sylgard{reg_sign} 184 and 186, were examined using thermal desorption coupled gas chromatography-mass spectrometry (TD/GC-MS) and multivariate analysis. This work describes a method of producing multiway data using a stepped thermal desorption. The technique involves sequentially heating a sample of the material of interest with subsequent analysis in a commercial GC/MS system. The decomposition chromatograms were analyzed using multivariate analysis tools including principal component analysis (PCA), factor rotation employing the varimax criterion, and multivariate curve resolution. The results of the analysis show seven components related to offgassing of various fractions of siloxanes that vary as a function of temperature. Thermal desorption coupled with gas chromatography-mass spectrometry (TD/GC-MS) is a powerful analytical technique for analyzing chemical mixtures. It has great potential in numerous analytic areas including materials analysis, sports medicine, in the detection of designer drugs; and biological research for metabolomics. Data analysis is complicated, far from automated and can result in high false positive or false negative rates. We have demonstrated a step-wise TD/GC-MS technique that removes more volatile compounds from a sample before extracting the less volatile compounds. This creates an additional dimension of separation before the GC column, while simultaneously generating three-way data. Sandia's proven multivariate analysis methods, when applied to these data, have several advantages over current commercial options. It also has demonstrated potential for success in finding and enabling identification of trace compounds. Several challenges remain, however, including understanding the sources of noise in the data, outlier detection, improving the data pretreatment and analysis methods, developing a software tool for ease of use by the chemist, and demonstrating our belief

  1. High-performance liquid chromatography-mass spectrometry analysis of plant metabolites in brassicaceae.

    Science.gov (United States)

    De Vos, Ric C H; Schipper, Bert; Hall, Robert D

    2012-01-01

    The Brassicaceae family comprises a variety of plant species that are of high economic importance as -vegetables or industrial crops. This includes crops such as Brassica rapa (turnip, Bok Choi), B. oleracea (cabbages, broccoli, cauliflower, etc.), and B. napus (oil seed rape), and also includes the famous genetic model of plant research, Arabidopsis thaliana (thale cress). Brassicaceae plants contain a large variety of interesting secondary metabolites, including glucosinolates, hydroxycinnamic acids, and flavonoids. These metabolites are also of particular importance due to their proposed positive effects on human health. Next to these well-known groups of phytochemicals, many more metabolites are of course also present in crude extracts prepared from Brassica and Arabidopsis plant material.High-pressure liquid chromatography coupled to mass spectrometry (HPLC-MS), especially if combined with a high mass resolution instrument such as a QTOF MS, is a powerful approach to separate, detect, and annotate metabolites present in crude aqueous-alcohol plant extracts. Using an essentially unbiased procedure that takes into account all metabolite mass signals from the raw data files, detailed information on the relative abundance of hundreds of both known and, as yet, unknown semipolar metabolites can be obtained. These comprehensive metabolomics data can then be used to, for instance, identify genetic markers regulating metabolic composition, determine effects of (a)biotic stress or specific growth conditions, or establish metabolite changes occurring upon food processing or storage.This chapter describes in detail a procedure for preparing crude extracts and performing comprehensive HPLC-QTOF MS-based profiling of semi-polar metabolites in Brassicaceae plant material. Compounds present in the extract can be (partially or completely) annotated based on their accurate mass, their MS/MS fragments and on other specific chemical characteristics such as retention time and UV

  2. Analysis of small carbohydrates in several bioactive botanicals by gas chromatography with mass spectrometry and liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Moldoveanu, Serban; Scott, Wayne; Zhu, Jeff

    2015-11-01

    Bioactive botanicals contain natural compounds with specific biological activity, such as antibacterial, antioxidant, immune stimulating, and taste improving. A full characterization of the chemical composition of these botanicals is frequently necessary. A study of small carbohydrates from the plant materials of 18 bioactive botanicals is further described. The study presents the identification of the carbohydrate using a gas chromatographic-mass spectrometric analysis that allows detection of molecules as large as maltotetraose, after changing them into trimethylsilyl derivatives. A number of carbohydrates in the plant (fructose, glucose, mannose, sucrose, maltose, xylose, sorbitol, and myo-, chiro-, and scyllo-inositols) were quantitated using a novel liquid chromatography with tandem mass spectrometric technique. Both techniques involved new method developments. The gas chromatography with mass spectrometric analysis involved derivatization and separation on a Rxi(®)-5Sil MS column with H2 as a carrier gas. The liquid chromatographic separation was obtained using a hydrophilic interaction type column, YMC-PAC Polyamine II. The tandem mass spectrometer used an electrospray ionization source in multiple reaction monitoring positive ion mode with the detection of the adducts of the carbohydrates with Cs(+) ions. The validated quantitative procedure showed excellent precision and accuracy allowing the analysis in a wide range of concentrations of the analytes.

  3. Multilaboratory validation of a method to confirm chloramphenicol in shrimp and crabmeat by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Hammack, Walter; Carson, Mary C; Neuhaus, Barbara K; Hurlbut, Jeffrey A; Nochetto, Cristina; Stuart, James S; Brown, Amy; Kilpatrick, Donna; Youngs, Kristl; Ferbos, Krystle; Heller, David N

    2003-01-01

    An existing method for chloramphenicol (CAP) determination in shrimp using a gas chromatograph with electron capture detector was adapted for confirmation of CAP with a liquid chromatograph interfaced to a triple quadrupole mass spectrometer. CAP residues are extracted from tissue with ethyl acetate, isolated via liquid-liquid extraction, and concentrated by evaporation. Extracts are chromatographed by using a reversed-phased column and analyzed by electrospray negative mode tandem mass spectrometry. Four product ions (m/z 152, 176, 194, and 257) of precursor m/z 321 were monitored. Moving from gas chromatography to liquid chromatography-tandem mass spectrometry improved the sensitivity of the method greatly, enabling reliable confirmation of CAP residues at 0.3 microg/kg (ppb). The method meets confirmation criteria recommended by the U.S. Food and Drug Administration and 4-point identification criteria established by the European Union. With slight modifications to accommodate different equipment, the method was validated in 3 laboratories.

  4. Monitoring of cefepime in human serum and plasma by micellar electrokinetic capillary chromatography: Improvement of sample preparation and validation by liquid chromatography coupled to mass spectrometry.

    Science.gov (United States)

    Šestáková, Nela; Theurillat, Regula; Sendi, Parham; Thormann, Wolfgang

    2017-02-20

    Cefepime monitoring in deproteinized human serum and plasma by micellar electrokinetic capillary chromatography and liquid chromatography coupled to mass spectrometry in presence of other drugs is reported. For micellar electrokinetic capillary chromatography, sample preparation comprised dodecylsulfate protein precipitation at pH 4.5 using an increased buffer concentration compared to that of a previous assay and removal of hydrophobic compounds with dichloromethane. This provided robust conditions for cefepime analysis in the presence of sulfamethoxazole and thus enabled its determination in samples of patients that receive co-trimoxazole. The liquid chromatography assay is based upon use of a column with a pentafluorophenyl-propyl modified and multi-endcapped stationary phase and the coupling to electrospray ionization with a single quadrupole detector. The performances of both assays with multi-level internal calibration were assessed with calibration and control samples and both assays were determined to be robust. Cefepime levels monitored by micellar electrokinetic capillary chromatography in samples from patients that were treated with cefepime only and with cefepime and co-trimoxazole were found to compare well with those obtained by liquid chromatography coupled to mass spectrometry. Cefepime drug levels determined by micellar electrokinetic capillary chromatography could thereby be validated. This article is protected by copyright. All rights reserved.

  5. Anion exchange SPE and liquid chromatography-tandem mass spectrometry in GHB analysis.

    Science.gov (United States)

    Elian, Albert A; Hackett, Jeffery

    2011-12-01

    In this study, the extraction of γ-hydroxybutyrate (GHB) from urine using solid-phase extraction (SPE) is described. SPE was performed on anion exchange columns after samples of urine had been diluted with de-ionized water. After application of the diluted samples containing GHB-d(6) as an internal standard, the sorbent was washed with deionized water and methanol and dried. The GHB was eluted from the SPE column with a solvent consisting of methanol containing 6% glacial acetic acid. The eluent was collected, evaporated to dryness, and dissolved in mobile phase (100 μL) for analysis by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in negative multiple reaction monitoring (MRM) mode. Liquid chromatography was performed in gradient mode employing a biphenyl column and a mobile phase consisting of acetontitrile (containing 0.1% formic acid) and 0.1% aqueous formic acid. The total run time for each analysis was less than 5 min. The limits of detection/quantification for this method were determined to be 50 and 100 ng/mL, respectively. The method was found to be linear from 500 ng/mL to 10,000 ng/mL (r(2)>0.995). The recovery of GHB was found to be greater than 75%. In this report, results of authentic urine samples analyzed for GHB by this method are presented. GHB concentrations in these samples were found to be range from less than 500 ng/mL to 5110 ng/mL.

  6. Determination of the origin of urinary norandrosterone traces by gas chromatography combustion isotope ratio mass spectrometry.

    Science.gov (United States)

    Hebestreit, Moritz; Flenker, Ulrich; Fusshöller, Gregor; Geyer, Hans; Güntner, Ute; Mareck, Ute; Piper, Thomas; Thevis, Mario; Ayotte, Christiane; Schänzer, Wilhelm

    2006-09-01

    On the one hand, 19-norandrosterone (NA) is the most abundant metabolite of the synthetic anabolic steroid 19-nortestosterone and related prohormones. On the other hand, small amounts are biosynthesized by pregnant women and further evidence exists for physiological origin of this compound. The World Anti-Doping Agency (WADA) formerly introduced threshold concentrations of 2 or 5 ng of NA per ml of urine to discriminate 19-nortestosterone abuse from biosynthetic origin. Recent findings showed however, that formation of NA resulting in concentrations in the range of the threshold levels might be due to demethylation of androsterone in urine, and the WADA 2006 Prohibited List has defined NA as endogenous steroid. To elucidate the endogenous or exogenous origin of NA, (13)C/(12)C-analysis is the method of choice since synthetic 19-nortestosterone is derived from C(3)-plants by partial synthesis and shows delta(13)C(VPDB)-values of around -28 per thousand. Endogenous steroids are less depleted in (13)C due to a dietary mixture of C(3)- and C(4)-plants. An extensive cleanup based on two high performance liquid chromatography cleanup steps was applied to quality control and doping control samples, which contained NA in concentrations down to 2 ng per ml of urine. (13)C/(12)C-ratios of NA, androsterone and etiocholanolone were measured by gas chromatography/combustion/isotope ratio mass spectrometry. By comparing delta(13)C(VPDB)-values of androsterone as endogenous reference compound with NA, the origin of NA in doping control samples was determined as either endogenous or exogenous.

  7. Collaborative trial validation study of two methods, one based on high performance liquid chromatography-tandem mass spectrometry and on gas chromatography-mass spectrometry for the determination of acrylamide in bakery and potato products.

    Science.gov (United States)

    Wenzl, Thomas; Karasek, Lubomir; Rosen, Johan; Hellenaes, Karl-Erik; Crews, Colin; Castle, Laurence; Anklam, Elke

    2006-11-03

    A European inter-laboratory study was conducted to validate two analytical procedures for the determination of acrylamide in bakery ware (crispbreads, biscuits) and potato products (chips), within a concentration range from about 20 microg/kg to about 9000 microgg/kg. The methods are based on gas chromatography-mass spectrometry (GC-MS) of the derivatised analyte and on high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) of native acrylamide. Isotope dilution with isotopically labelled acrylamide was an integral part of both methods. The study was evaluated according to internationally accepted guidelines. The performance of the HPLC-MS/MS method was found to be superior to that of the GC-MS method and to be fit-for-the-purpose.

  8. Characterization of intact protein conjugates and biopharmaceuticals using ion-exchange chromatography with online detection by native electrospray ionization mass spectrometry and top-down tandem mass spectrometry.

    Science.gov (United States)

    Muneeruddin, Khaja; Nazzaro, Mark; Kaltashov, Igor A

    2015-10-06

    Characterization of biopharmaceutical products is a challenging task, which needs to be carried out at several different levels (including both primary structure and conformation). An additional difficulty frequently arises due to the structural heterogeneity inherent to many protein-based therapeutics (e.g., extensive glycosylation or "designer" modifications such as chemical conjugation) or introduced postproduction as a result of stress (e.g., oxidation and deamidation). A combination of ion-exchange chromatography (IXC) with online detection by native electrospray ionization mass spectrometry (ESI MS) allows characterization of complex and heterogeneous therapeutic proteins and protein conjugates to be accomplished at a variety of levels without compromising their conformational integrity. The IXC/ESI MS measurements allow protein conjugates to be profiled by analyzing conjugation stoichiometry and the presence of multiple positional isomers, as well as to establish the effect of chemical modifications on the conformational integrity of each species. While mass profiling alone is not sufficient for identification of nonenzymatic post-translational modifications (PTMs) that result in a very small mass change of the eluting species (e.g., deamidation), this task can be completed using online top-down structural analysis, as demonstrated using stressed interferon-β as an example. The wealth of information that can be provided by IXC/native ESI MS and tandem mass spectrometry (MS/MS) on protein-based therapeutics will undoubtedly make it a very valuable addition to the experimental toolbox of biopharmaceutical analysis.

  9. Investigation of isovaline enantiomeric excesses in CM meteorites using liquid chromatography time of flight mass spectrometry

    Science.gov (United States)

    Glavin, Daniel P.; Dworkin, Jason P.

    2003-01-01

    The enantiomeric abundances of the alpha-dialkyl amino acid isovaline were measured in the CM2 meteorites Murchison and LEW 90500 using a new liquid chromatography-time of flight-mass spectrometry (LC-ToF-MS) technique coupled with OPA/NAC derivatization and UV fluorescence detection. Previous analyses of Murchison have shown that L-enantiomeric excesses of isovaline range from 0 to 15.2% with significant variation between meteorite fragments [1]. For this study, hot water extracts of interior fragments (> 2 cm from fusion crust) of the Murchison (USNM 6650.2, mass 6 g) and LEW 90500 (split 69, parent 1, mass 5 g) carbonaceous meteorites were analyzed. Enantiomeric excesses were measured using the single ion LC-ToF-MS trace for the OPA/NAC derivative of isovaline at d z 393.15 (Fig. 1). L-isovaline excesses in these meteorite samples ranged from 18.9 to 20.5% for Murchison and -0.5 to 3.0% for LEW 90500. The measured values for Murchison are the largest enantiomeric excesses for isovaline reported to date. The enantiomeric excesses of L-isovaline cannot be the result of interference from other C5 amino acid isomers present in the meteorites or terrestrial contamination from the landing site environments. The L-isovaline excesses in Murchison are inconsistent with the synthesis of all of the isovaline by the Strecker-cyanohydrin pathway on the CM meteorite parent body. The mechanism(s) for the formation of the enantiomeric asymmetry in isovaline in Murchison are currently unknown and it is not clear how the asymmetry of alpha-dialkyl amino acids could be transferred to the a-hydrogen protein amino acids common in all life on Earth today.

  10. Proteomic analysis of Taenia ovis metacestodes by high performance liquid chromatography-coupled tandem mass spectrometry.

    Science.gov (United States)

    Zheng, Yadong

    2017-03-15

    Taenia ovis metacestodes reside in the muscle of sheep and goats, and may cause great economic loss due to condemnation of carcasses if not effectively controlled. Although advances have been made in the control of T. ovis infection, our knowledge of T. ovis biology is limited. Herein the protein profiling of T. ovis metacestodes was determined by liquid chromatography-linked tandem mass spectrometry. A total of 966 proteins were identified and 25.1% (188/748) were annotated to be associated with metabolic pathways. Consistently, GO analysis returned a metabolic process (16.27%) as one of two main biological process terms. Moreover, it was found that 24 proteins, including very low-density lipoprotein receptor, enolase, paramyosin and endophilin B1, were abundant in T. ovis metacestodes. These proteins may be associated with motility, metabolism, signaling, stress, drug resistance and immune responses. Furthermore, comparative analysis of 5 cestodes revealed the presence of Taenia-specific enolases. These data provide clues for better understanding of T. ovis biology, which is informative for effective control of infection.

  11. Determination of multiple human arsenic metabolites employing high performance liquid chromatography inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Stice, Szabina; Liu, Guangliang; Matulis, Shannon; Boise, Lawrence H.; Cai, Yong

    2016-01-01

    During the metabolism of different arsenic-containing compounds in human, a variety of metabolites are produced with significantly varying toxicities. Currently available analytical methods can only detect a limited number of human metabolites in biological samples during one run due to their diverse characteristics. In addition, co-elution of species is often unnoticeable with most detection techniques leading to inaccurate metabolic profiles and assessment of toxicity. A high performance liquid chromatography inductively coupled mass spectrometry (HPLC-ICP-MS) method was developed that can identify thirteen common arsenic metabolites possibly present in human with special attention dedicated to thiolated or thiol conjugated arsenicals. The thirteen species included in this study are arsenite (AsIII), arsino-glutathione (As(GS)3), arsenate (AsV), monomethylarsonous acid (MMAIII), monomethylarsino-glutathione (MMAIII(GS)2), monomethylarsonic acid (MMAV), dimethylarsinous acid (DMAIII (from DMAIIII)), S-(dimethylarsinic)cysteine (DMAIII(Cys)), dimethylarsino-glutathione (DMAIII(GS)), dimethylarsinic acid (DMAV), dimethylmonothioarsinic acid (DMMTAV), dimethyldithioarsinic acid (DMDTAV), dimethylarsinothioyl glutathione (DMMTAV(GS)). The developed method was applied for the analysis of cancer cells that were incubated with Darinaparsin (DMAIII(GS)), a novel chemotherapeutic agent for refractory malignancies, and the arsenic metabolic profile obtained was compared to results using a previously developed method. This method provides a useful analytical tool which is much needed in unequivocally identifying the arsenicals formed during the metabolism of environmental arsenic exposure or therapeutic arsenic administration. PMID:26708625

  12. [Determination of seven toxaphene congeners in ginseng and milkvetch root by gas chromatography tandem mass spectrometry].

    Science.gov (United States)

    Tian, Shaoqiong; Mao, Xiuhong; Miao, Shui; Jia, Zhengwei; Wang, Ke; Ji, Shen

    2012-01-01

    A novel method for the determination of representative toxaphene congeners in traditional Chinese herbal medicines was developed. Ginseng and Milkvetch Root were selected as the samples and seven toxaphene congeners were selected as the monitoring objects. The samples were extracted by accelerated solvent extraction with cyclohexane-acetone (9:1, v/v), then cleaned-up by Florisil solid phase extraction with hexane as the eluent and the residues were detected by gas chromatography-electron ionization tandem mass spectrometry (GC-EI-MS/MS) in multiple reaction monitoring (MRM) mode. The performance was demonstrated by the analysis of Ginseng and Milkvetch Root samples spiked with toxaphene congeners at three concentration levels of 0.005, 0.01 and 0.1 mg/kg. The recoveries ranged from 72.4% to 105% with the relative standard deviations (RSDs) of 0.96%-10.4%. The limits of detection (LODs) were 0.2-1.7 microg/kg. This method is sensitive and efficient in the aspect of extraction, and can be applied to monitor the residue of toxaphene congeners in Ginseng and Milkvetch Root.

  13. [Serum metabolomics analysis on benign prostate hyperplasia in mice based on liquid chromatography-mass spectrometry].

    Science.gov (United States)

    Geng, Yue; Sun, Fengxia; Ma, Yu; Deng, Ligang; Lü, Jianyun; Li, Teng; Wang, Congcong

    2014-12-01

    Benign prostatic hyperplasia (BPH) increasingly becomes a common factor affecting the quality of life of aging men. Its pathogenesis has not yet been fully elucidated. Ultra-high pressure liquid chromatography-quadrupole time-of-flight mass spectrometry (UPLC-QTOF-MS) was employed to detect the changes of serum metabolites in normal mice, benign prostatic hyperplasia model mice and BPH model mice with finasteride intervention. The serum metabolite profiles of the three groups of mice were analyzed. Partial least squares-discriminant analysis (PLS-DA) was used for group differentiation and biomarker selection. The results showed good distinction among the three groups of mice serum metabolite spectra. Three potential biomarkers, 1-hexadecanoyl-SN-glycero-3-phosphocholine, 1-O-hexadecyl-2-O-acetyl-sn-glyceryl-3-phosphorylcholine and (Z)-13-docosenamide, were discovered and identified. They all indicated the occurrence of benign prostatic hypertrophy is closely related to the disorders of lipid metabolism. Coinpared with the control group, the contents of the first two substances were significantly increased in the serum of BPH model mice, and significantly decreased after intervened by finasteride. The contents of (Z)-13-docosenamide decreased significantly in the serum of model group, and increased after intervened by finasteride. Compared with the control group, the contents of three biomarkers in finasteride group did not recover completely and had significant differences. This study is conductive to open new avenues of diagnosis and medical treatment for BPH.

  14. Determination of fenbendazole and oxfendazole in liver and muscle using liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Blanchflower, W J; Cannavan, A; Kennedy, D G

    1994-06-01

    A method has been developed for the determination of the anthelmintics fenbendazole and oxfendazole in liver and muscle samples using liquid chromatography-thermospray mass spectrometry (LC-MS). The samples were homogenized with water, sonicated with methanol and centrifuged. The supernatants were washed with light petroleum and extracted with diethyl ether-ethyl acetate. The extracts were evaporated to dryness, dissolved in mobile phase and injected into the LC-MS system. Fenbendazole and oxfendazole were measured separately using two different mobile phases. Single-ion monitoring of the positive ion at m/z 300 was used for fenbendazole and of m/z 316 for oxfendazole. The detection limits for the assay were 0.05 microgram g-1 for fenbendazole and 0.1 microgram g-1 for oxfendazole. The mean recoveries were 91% for fenbendazole and 86% for oxfendazole. The assay has been used for statutory testing purposes and for measuring the levels of fenbendazole and oxfendazole in liver and muscle from sheep after dosing with a commercial anthelmintic containing fenbendazole.

  15. Analysis of volatile compounds of Malaysian Tualang (Koompassia excelsa) honey using gas chromatography mass spectrometry.

    Science.gov (United States)

    Nurul Syazana, M S; Gan, S H; Halim, A S; Shah, Nurul Syazana Mohamad; Gan, Siew Hua; Sukari, Halim Ahmad

    2013-01-01

    The constituents of honey's volatile compounds depend on the nectar source and differ depending on the place of origin. To date, the volatile constituents of Tualang honey have never been investigated. The objective of this study was to analyze the volatile compounds in local Malaysian Tualang honey. A continuous extraction of Tualang honey using five organic solvents was carried out starting from non-polar to polar solvents and the extracted samples were analysed using gas chromatography-mass spectrometry (GC-MS). Overall, 35 volatile compounds were detected. Hydrocarbons constitute 58.5% of the composition of Tualang honey. Other classes of chemical compounds detected included acids, aldehydes, alcohols, ketones, terpenes, furans and a miscellaneous group. Methanol yielded the highest number of extracted compounds such as acids and 5-(Hydroxymethyl) furfural (HMF). This is the first study to describe the volatile compounds in Tualang honey. The use of a simple one tube, stepwise, non-thermal liquid-liquid extraction of honey is a advantageous as it prevents sample loss. Further research to test the clinical benefits of these volatile compounds is recommended.

  16. Determination of the Thyreostats in Animal Feeding Stuffs Using Liquid Chromatography-Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Woźniak Barbara

    2014-10-01

    Full Text Available A rapid liquid chromatography tandem mass spectrometry method was developed and validated to detect and confirm five thyreostatic drugs: tapazole, thiouracil, methylthiouracil, propylthiouracil, and phenylthiouracil in animal feeding stuff samples. Thyreostats were extracted from feed with methanol, and then degreasing of the extract with petroleum ether was performed, followed by the derivatisation of the compounds with 3-iodobenzylbromide in basic medium (pH 8.0. The derivatives were extracted with diethyl ether and analysed by gradient elution on a Poroshell 120-EC C18 column with triple quadrupole MS detection with turbo spray source in positive ionisation mode. The method was validated in accordance with the Commission Decision 2002/657/EC. For validation level of 10 ļig kg-1, the recovery ranged from 82% to 97.5% for all examined compounds. The repeatability and reproducibility did not exceed the limit of 20% for all analytes. The linearity was good for all thyreostats in the whole range of tested concentrations, as proved by the correlation coefficients greater than 0.99. The decision limits (CCa ranged from 1.63 ļig kg-1 to 3.95 ļig kg-1, whereas the detection capabilities (CCß ranged from 2.74 ļig kg-1 to 6.73 ļig kg-1. The developed analysis is sensitive and robust, and therefore useful for quantification and confirmation of thyreostats in residue control programme.

  17. Data preprocessing method for liquid chromatography-mass spectrometry based metabolomics.

    Science.gov (United States)

    Wei, Xiaoli; Shi, Xue; Kim, Seongho; Zhang, Li; Patrick, Jeffrey S; Binkley, Joe; McClain, Craig; Zhang, Xiang

    2012-09-18

    A set of data preprocessing algorithms for peak detection and peak list alignment are reported for analysis of liquid chromatography-mass spectrometry (LC-MS)-based metabolomics data. For spectrum deconvolution, peak picking is achieved at the selected ion chromatogram (XIC) level. To estimate and remove the noise in XICs, each XIC is first segmented into several peak groups based on the continuity of scan number, and the noise level is estimated by all the XIC signals, except the regions potentially with presence of metabolite ion peaks. After removing noise, the peaks of molecular ions are detected using both the first and the second derivatives, followed by an efficient exponentially modified Gaussian-based peak deconvolution method for peak fitting. A two-stage alignment algorithm is also developed, where the retention times of all peaks are first transferred into the z-score domain and the peaks are aligned based on the measure of their mixture scores after retention time correction using a partial linear regression. Analysis of a set of spike-in LC-MS data from three groups of samples containing 16 metabolite standards mixed with metabolite extract from mouse livers demonstrates that the developed data preprocessing method performs better than two of the existing popular data analysis packages, MZmine2.6 and XCMS(2), for peak picking, peak list alignment, and quantification.

  18. Determination of free and ethoxylated alkylphenols in leather with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Ma, He-Wei; Cheng, Ya

    2010-12-10

    An analytical approach was developed to determine nonylphenol (NP), octylphenol (OP), nonylphenol ethoxylates (NPEO(n)) and octylphenol ethoxylates (OPEO(n)) in leather samples involving the conversion of NPEO(n) and OPEO(n) into the corresponding NP and OP. The four targets were extracted from samples using ultrasonic-assisted acetonitrile extraction. NP and OP in the extracts were directly isolated with hexane and quantitatively determined with 4-n-nonylphenol as internal standard by gas chromatography-mass spectrometry (GC-MS). For NPEO(n) and OPEO(n) in the extracts, they were first converted into NP and OP with aluminum triiodide as cleavage agent, and the yielded NP and OP were determined by GC-MS. The contents of NPEO(n) and OPEO(n) were calculated by normalizing to NPEO(9) and OPEO(9), respectively. This method was properly validated and the real sample tests revealed the pollution significance of leather by NPEO(n) and OPEO(n).

  19. Global Analysis of the Membrane Subproteome of Pseudomonas aeruginosa using Liquid Chromatography-Tandem Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Blonder, Josip; Goshe, Michael B.; Xiao, Wenzhong; Camp, David G.; Wingerd, Mark A.; Davis, Ronald W.; Smith, Richard D.

    2004-05-30

    Pseudomonas aeruginosa is one of the most significant opportunistic bacterial pathogens in humans causing infections and premature death in patients with cystic fibrosis, AIDS, severe burns, organ transplants or cancer. Liquid chromatography coupled online with tandem mass spectrometry (LC-MS/MS) was used for the large-scale proteomic analysis of the P. aeruginosa membrane subproteome. Concomitantly, an affinity labeling technique, using iodoacetyl-PEO biotin to tag cysteinyl-containing proteins, permitted the enrichment and detection of lower abundance membrane proteins. The application of these approaches resulted in the identification of 786 proteins. A total of 333 proteins (42%) had a minimum of one transmembrane domain (TMD; ranging from 1 to 14) and 195 proteins were classified as hydrophobic based on their positive GRAVY values (ranging from 0.01 to 1.32). Key integral inner and outer membrane proteins involved in adaptation and antibiotic resistance were conclusively identified, including the detection of 53% of all predicted opr-type porins (outer integral membrane proteins) and all the components of the mexA-mexB-oprM transmembrane protein complex. This work represents the most comprehensive qualitative proteomic analysis of the membrane subproteome of P. aeruginosa and for prokaryotes in general to date.

  20. Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Baxter, Douglas C; Faarinen, Mikko; Österlund, Heléne; Rodushkin, Ilia; Christensen, Morten

    2011-09-01

    A method for the determination of methylmercury in plasma and serum samples was developed. The method uses isotope dilution with (198)Hg-labeled methylmercury, extraction into dichloromethane, back-extraction into water, aqueous-phase ethylation, purge and trap collection, thermal desorption, separation by gas chromatography, and mercury isotope specific detection by inductively coupled plasma mass spectrometry. By spiking 2 mL sample with 1.2 ng tracer, measurements in a concentration interval of (0.007-2.9) μg L(-1) could be performed with uncertainty amplification factors levels of 0.14 μg L(-1), 0.35 μg L(-1) and 2.8 μg L(-1), with recoveries in the range 82-110%. Application of the method to 50 plasma/serum samples yielded a median (mean; range) concentration of methylmercury of 0.081 (0.091; methylmercury has been directly measured in this kind of specimen, and is therefore the first estimate of a reference range.

  1. Identification and differentiation of dragon's blood in works of art using gas chromatography/mass spectrometry.

    Science.gov (United States)

    Baumer, Ursula; Dietemann, Patrick

    2010-06-01

    Dragon's blood is a common but non-specific name for red-coloured resins that are produced by various plants, particularly exudations from plant species belonging to the genera Dracaena and Daemonorops. Although dragon's blood is mentioned in historic sources as a colourant, it has hardly ever been identified in real artworks. This paper reports the identification and discrimination of dragon's blood produced by Dracaena cinnabari, Dracaena draco as well as Daemonorops draco and Daemonorops micracantha by means of gas chromatography/mass spectrometry (GC/MS) within the context of a routine analysis of binding media used in works of art. The detection of specific flavonoid marker compounds in both underivatised and methylated methanol extracts provided the first evidence for the use of dragon's blood from all four species in various works of art from the fifteenth to nineteenth centuries. Dragon's blood was mainly used as a red colourant in gold lacquers as well as translucent glazes and paints, e.g. in reverse-glass paintings (Hinterglasmalerei).

  2. Gluten Detection and Speciation by Liquid Chromatography Mass Spectrometry (LC-MS/MS

    Directory of Open Access Journals (Sweden)

    Stephen Lock

    2013-12-01

    Full Text Available Liquid chromatography tandem mass spectrometry (LC-MS/MS has been used historically in proteomics research for over 20 years. However, until recently LC-MS/MS has only been routinely used in food testing for small molecule contaminant detection, for example pesticide and veterinary residue detection, and not as a replacement of microbiological food testing methods, specifically allergen analysis. Over the last couple of years, articles have started to be published which describe the detection of allergens by LC-MS/MS. In this article we will describe how LC-MS/MS can be applied in the area of gluten detection and how it can be used to specifically differentiate the species of gluten used in food, where specific markers for each variety of gluten can be simultaneously acquired and detected at the same time. The article will discuss the effect of variety on the peptide response observed from different wheat grain varieties and will describe the sample preparation protocol which is essential for generating the peptide markers used for speciation.

  3. [Determination of 25 quinolones in cosmetics by liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Lin, Li; Zhang, Yi; Tu, Xiaoke; Xie, Liqi; Yue, Zhenfeng; Kang, Haining; Wu, Weidong; Luo, Yao

    2015-03-01

    An analytical method was developed for the simultaneous determination of 25 quinolones, including danofloxacin mesylate, enrofloxacin, flumequine, oxloinic acid, ciprofloxacin, sarafloxacin, nalidixic acid, norfloxacin, and ofloxacin etc in cosmetics using direct extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). Cosmetic sample was extracted by acidified acetonitrile, defatted by n-hexane and separated on Poroshell EC-C18 column with gradient elution program using acetonitrile and water (both containing 0. 1% formic acid) as the mobile phases and analyzed by LC-ESI-MS/MS under the positive mode using multiple reaction monitoring (MRM). The interference of matrix was reduced by the matrix-matched calibration standard curve. The method showed good linearities over the range of 1-200 mg/kg for the 25 quinolones with good linear correlation coefficients (r ≥ 0.999). The method detection limit of the 25 quinolones was 1.0 mg/kg, and the recoveries of all analytes in lotion, milky and cream cosmetics matrices ranged from 87.4% to 105% at the spiked levels of 1, 5 and 10 mg/kg with the relative standard deviations (RSD) of 4.54%-19.7% (n = 6). The results indicated that this method is simple, fast and credible, and suitable for the simultaneous determination of the quinolones in the above three types of cosmetics.

  4. Antibiotic toxicity and absorption in zebrafish using liquid chromatography-tandem mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Fan Zhang

    Full Text Available Evaluation of drug toxicity is necessary for drug safety, but in vivo drug absorption is varied; therefore, a rapid, sensitive and reliable method for measuring drugs is needed. Zebrafish are acceptable drug toxicity screening models; we used these animals with a liquid chromatography-tandem mass spectrometry (LC-MS/MS method in a multiple reaction monitoring mode to quantify drug uptake in zebrafish to better estimate drug toxicity. Analytes were recovered from zebrafish homogenate by collecting supernatant. Measurements were confirmed for drugs in the range of 10-1,000 ng/mL. Four antibiotics with different polarities were tested to explore any correlation of drug polarity, absorption, and toxicity. Zebrafish at 3 days post-fertilization (dpf absorbed more drug than those at 6 h post-fertilization (hpf, and different developmental periods appeared to be differentially sensitive to the same compound. By observing abnormal embryos and LD50 values, zebrafish embryos at 6 hpf were considered to be suitable for evaluating embryotoxicity. Also, larvae at 3 dpf were adapted to measure acute drug toxicity in adult mammals. Thus, we can exploit zebrafish to study drug toxicity and can reliably quantify drug uptake with LC-MS/MS. This approach will be helpful for future studies of toxicology in zebrafish.

  5. Characterization of impurities in tylosin using dual liquid chromatography combined with ion trap mass spectrometry.

    Science.gov (United States)

    Chopra, Shruti; Van Schepdael, Ann; Hoogmartens, Jos; Adams, Erwin

    2013-03-15

    Investigation of unknown impurities in a tylosin sample was performed using liquid chromatography coupled to mass spectrometry (LC/MS). Separation was performed according to the recently described LC-UV method of Ashenafi et al. (2011) [14]. This method was reported to have a good selectivity as it was able to separate the four main components of tylosin from the already known and 23 unknown impurities. However, as this method uses a mobile phase with non-volatile constituents, direct characterization of these impurities using LC/MS was not possible. The impurity fractions were therefore first collected and then desalted before sending them to the MS. Identification of the impurities in the tylosin sample was performed with a quadruple ion trap (IT) MS, with an electrospray ionization (ESI) source in the positive ion mode. The structure of the impurities was deduced by comparing their fragmentation pattern with those of the main components of tylosin. As several peaks in the LC-UV method contained multiple compounds, using this method in total 41 new impurities were (partly) characterized.

  6. Gas chromatography-mass spectrometry profiles of urinary organic acids in healthy captive cheetahs (Acinonyx jubatus).

    Science.gov (United States)

    Tordiffe, Adrian Stephen Wolferstan; van Reenen, Mari; Reyers, Fred; Mienie, Lodewyk Jacobus

    2017-04-01

    In captivity, cheetahs (Acinonyx jubatus) frequently suffer from several unusual chronic diseases that rarely occur in their free-ranging counterparts. In order to develop a better understanding of their metabolism and health we documented the urine organic acids of 41 apparently healthy captive cheetahs, in an untargeted metabolomic study, using gas chromatography-mass spectrometry. A total of 339 organic acids were detected and annotated. Phenolic compounds, thought to be produced by the anaerobic fermentation of aromatic amino acids in the distal colon, as well as their corresponding glycine conjugates, were present in high concentrations. The most abundant organic acids in the cheetahs' urine were an as yet unidentified compound and a novel cadaverine metabolite, tentatively identified as N(1),N(5)-dimethylpentane-1,5-diamine. Pantothenic acid and citramalic acid concentrations correlated negatively with age, while glutaric acid concentrations correlated positively with age, suggesting possible dysregulation of coenzyme A metabolism in older cheetahs. This study provides a baseline of urine organic acid reference values in captive cheetahs and suggests important avenues for future research in this species.

  7. Determination of sulfonamides in beeswax by liquid chromatography coupled to tandem mass spectrometry.

    Science.gov (United States)

    Mitrowska, Kamila; Antczak, Maja

    2015-12-01

    The manuscript presents the development of a new method for the quantification of 16 sulfonamides in beeswax. Different sample preparation techniques were tested and modified to maximise the recovery of the target analytes and minimise the amount of coeluted impurities under conditions that provide reproducible results. The proposed method consisted of melting and dilution of beeswax in a mixture of n-hexane and isopropanol followed by extraction with 2% acetic acid. The extract was cleaned up by solid-phase extraction using strong cation exchange phase. Determination of the sulfonamides was achieved by liquid chromatography coupled to tandem mass spectrometry with the use of a pentafluorophenyl analytical column and applying a gradient elution with acetonitrile and 0.01% acetic acid as mobile phases. The limits of detection and limits of quantification ranged from 1 to 2μg/kg and from 2 to 5μg/kg, respectively. The recoveries varied between 65.2% and 117.8% while coefficient of variation of the method was less than 24.2% under intermediate precision conditions. Finally, the method was applied to the analysis of real samples of beeswax from beekeepers and commercial foundations manufacturers.

  8. Quantitative determination of trisiloxane surfactants in beehive environments based on liquid chromatography coupled to mass spectrometry.

    Science.gov (United States)

    Chen, Jing; Mullin, Christopher A

    2013-08-20

    Organosilicone surfactants are increasingly being applied to agricultural agro-ecosystems as spray adjuvants, and were recently shown to impact the learning ability of honey bees. Here we developed a method for analyzing three trisiloxane surfactants (single polyethoxylate (EO) chain and end-capped with methyl, acetyl, or hydroxyl groups; TSS-CH3, TSS-COCH3, or TSS-H) in beehive matrices based on liquid chromatography coupled to mass spectrometry (LC-MS) and the QuEChERS (quick, easy, cheap, effective, rugged, and safe) approach from less than 2 g of honey, pollen, or beeswax. Recoveries for each oligomer (2-13 EO) were between 66 and 112% in all matrices. Average method detection limits (MDL) were 0.53, 0.60, 0.56 ng/g in honey, 0.63, 0.81, 0.78 ng/g in pollen, and 0.51, 0.69, 0.63 ng/g in beeswax. Five honey, 10 pollen, and 10 beeswax samples were analyzed. Trisiloxane surfactants were detected in every beeswax and 60% of the pollen samples. Total trisiloxane surfactant concentrations were up to 390 and 39 ng/g in wax and pollen. The described method is proved suitable for analyzing trisiloxane surfactants in beehive samples. The presence of trisiloxane surfactants in North American beehives calls for renewed effort to investigate the consequence of these adjuvants to bee health and the ongoing global bee decline.

  9. Headspace Analysis of Philippine Civet Coffee Beans Using Gas Chromatography-Mass Spectrometry and Electronic Nose

    Science.gov (United States)

    Ongo, E.; Sevilla, F.; Antonelli, A.; Sberveglieri, G.; Montevecchi, G.; Sberveglieri, V.; de Paola, E. L.; Concina, I.; Falasconi, M.

    2011-11-01

    Civet coffee, the most expensive and best coffee in the world, is an economically important export product of the Philippines. With a growing threat of food adulteration and counterfeiting, a need for quality authentication is essential to protect the integrity and strong market value of Philippine civet coffee. At present, there is no internationally accepted method of verifying whether a bean is an authentic civet coffee. This study presented a practical and promising approach to identify and establish the headspace qualitative profile of Philippine civet coffee using electronic nose (E-nose) and gas chromatography-mass spectrometry (GC-MS). E-nose analysis revealed that aroma characteristic is one of the most important quality indicators of civet coffee. The findings were supported by GC-MS analysis. Principal component analysis (PCA) exhibited a clearly separated civet coffees from their control beans. The chromatographic fingerprints indicated that civet coffees differed with their control beans in terms of composition and concentration of individual volatile constituents.

  10. Multiresidue analysis of environmental pollutants in edible vegetable oils by gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Rui-Ze; Jiang, Jie; Mao, Ting; Zhao, Ya-Song; Lu, Yong

    2016-09-15

    A novel multiresidue determination of polycyclic aromatic hydrocarbons (PAHs), phthalate esters (PAEs) and alkylphenols (APs) in edible vegetable oils was developed. The samples were extracted with hexane-saturated acetonitrile, and after concentration, the extract was directly qualitatively and quantitatively analyzed by gas chromatography-tandem mass spectrometry (GC-MS/MS) with multiple reaction monitoring (MRM) in positive ion mode. The calibration curve displayed good linearity in the range of 2-100 μg/L, with correlation coefficients greater than 0.99. The mean recoveries were 70.0-110.8% by analysis of spiked oil, and the relative standard deviations (RSDs) were 2.1-10.2% (n=6), respectively. The limits of detection (LODs) for the 23 PAHs, 17 PAEs and 3 APs were 0.1-1.0 μg/kg, 0.1-4.0 μg/kg and 1.2-3.0 μg/kg, respectively. The established method effectively avoided interference from large amounts of lipids and pigments. It was applied to real sample and shown to be a rapid and reliable alternative for determination and confirmation in routine analysis.

  11. Simultaneous determination of acidic pesticides in vegetables and fruits by liquid chromatography--tandem mass spectrometry.

    Science.gov (United States)

    Shida, Shizuka S; Nemoto, Satoru; Matsuda, Rieko

    2015-01-01

    A sensitive and efficient method has been developed for the simultaneous determination of 73 multi-class acidic pesticides, such as phenoxy acid and sulfonylurea herbicides, in vegetables and fruits. The sample preparation procedure was carefully optimized for the efficient removal of co-extracted matrix components. The method involves extraction of acidic pesticides with acetonitrile containing hydrochloric acid, removal of water from crude extract by salting out, and sequential cleanup by octadecylsilyl silica gel and silica gel columns. For samples containing high amounts of pigments, such as spinach, additional cleanup using a graphitized carbon column was performed prior to liquid chromatography-mass spectrometry (LC-MS/MS) analysis. Recovery tests were performed for five times for each sample of cabbage, spinach, potato, eggplant, orange, and apple fortified at 0.01 mg kg-1. Out of the 73 tested pesticides, 70 for cabbage, 67 for spinach, 69 for potato, 67 for eggplant, 64 for orange, and 70 for apple were within the range of 70-120%, with relative standard deviations below 25%. Nitenpyram and pyrasulfotole showed low recoveries for all the samples tested, probably due to low recoveries from silica gel column. The developed method effectively removed co-extracted matrix components and was highly selective, with no interfering peaks found in the chromatograms of blank samples. The overall results indicate that the developed method is suitable for the quantitative analysis of acidic pesticide residues in vegetables and fruits.

  12. Analysis of plant nucleotide sugars by hydrophilic interaction liquid chromatography and tandem mass spectrometry.

    Science.gov (United States)

    Ito, Jun; Herter, Thomas; Baidoo, Edward E K; Lao, Jeemeng; Vega-Sánchez, Miguel E; Michelle Smith-Moritz, A; Adams, Paul D; Keasling, Jay D; Usadel, Björn; Petzold, Christopher J; Heazlewood, Joshua L

    2014-03-01

    Understanding the intricate metabolic processes involved in plant cell wall biosynthesis is limited by difficulties in performing sensitive quantification of many involved compounds. Hydrophilic interaction liquid chromatography is a useful technique for the analysis of hydrophilic metabolites from complex biological extracts and forms the basis of this method to quantify plant cell wall precursors. A zwitterionic silica-based stationary phase has been used to separate hydrophilic nucleotide sugars involved in cell wall biosynthesis from milligram amounts of leaf tissue. A tandem mass spectrometry operating in selected reaction monitoring mode was used to quantify nucleotide sugars. This method was highly repeatable and quantified 12 nucleotide sugars at low femtomole quantities, with linear responses up to four orders of magnitude to several 100pmol. The method was also successfully applied to the analysis of purified leaf extracts from two model plant species with variations in their cell wall sugar compositions and indicated significant differences in the levels of 6 out of 12 nucleotide sugars. The plant nucleotide sugar extraction procedure was demonstrated to have good recovery rates with minimal matrix effects. The approach results in a significant improvement in sensitivity when applied to plant samples over currently employed techniques.

  13. Determination of polyphenolic compounds by liquid chromatography-mass spectrometry in Thymus species.

    Science.gov (United States)

    Boros, Borbála; Jakabová, Silvia; Dörnyei, Agnes; Horváth, Györgyi; Pluhár, Zsuzsanna; Kilár, Ferenc; Felinger, Attila

    2010-12-17

    Polyphenolic compounds represent a wide group of phytochemicals, including well-known subgroups of phenolic acids, flavonoids, natural dyes, lignans etc., which are produced by plants. These natural bioactive compounds possess a variety of beneficial effects including antioxidant and anticarcinogenic activities, protection against coronary diseases as well as antimicrobial properties. Thymus species have already been reported as sources of different phenolic acids and flavonoids. Moreover, the composition and content of flavonoids in Thymus species play important role as taxonomic markers providing distinction of species. High-performance liquid chromatography (HPLC) coupled with diode array detector (DAD) and on-line mass spectrometry (ESI-MS) method was used for analysis. The method was evaluated for a number of validation characteristics (repeatability and intermediate precision, LOD, LOQ, calibration range, and recovery). The polyphenolic pattern of five native Hungarian Thymus species (T. glabrescens Willd., T. pannonicus All., T. praecox Opiz, T. pulegioides L., and T. serpyllum L.) was characterized. The dominant compound was rosmarinic acid, which ranged between 83.49 μg g(-1) and 1.436 mg g(-1). Other phenolic acids (ferulic acid, caffeic acid and its other derivatives, chlorogenic acid and p-coumaric acids) were present in every examined Thymus species, as well as flavanones: naringenin, eriodictyol and dihydroquercetin; flavones: apigenin and apigenin-7-glucoside, flavonols: quercetin and rutin. The polyphenolic pattern was found to be a useful additional chemotaxonomic tool for classification purposes and determination of the locality of origin.

  14. Chemical Discrimination in Turbulent Gas Mixtures with MOX Sensors Validated by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Jordi Fonollosa

    2014-10-01

    Full Text Available Chemical detection systems based on chemo-resistive sensors usually include a gas chamber to control the sample air flow and to minimize turbulence. However, such a kind of experimental setup does not reproduce the gas concentration fluctuations observed in natural environments and destroys the spatio-temporal information contained in gas plumes. Aiming at reproducing more realistic environments, we utilize a wind tunnel with two independent gas sources that get naturally mixed along a turbulent flow. For the first time, chemo-resistive gas sensors are exposed to dynamic gas mixtures generated with several concentration levels at the sources. Moreover, the ground truth of gas concentrations at the sensor location was estimated by means of gas chromatography-mass spectrometry. We used a support vector machine as a tool to show that chemo-resistive transduction can be utilized to reliably identify chemical components in dynamic turbulent mixtures, as long as sufficient gas concentration coverage is used. We show that in open sampling systems, training the classifiers only on high concentrations of gases produces less effective classification and that it is important to calibrate the classification method with data at low gas concentrations to achieve optimal performance.

  15. Chemical discrimination in turbulent gas mixtures with MOX sensors validated by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Fonollosa, Jordi; Rodríguez-Luján, Irene; Trincavelli, Marco; Vergara, Alexander; Huerta, Ramón

    2014-10-16

    Chemical detection systems based on chemo-resistive sensors usually include a gas chamber to control the sample air flow and to minimize turbulence. However, such a kind of experimental setup does not reproduce the gas concentration fluctuations observed in natural environments and destroys the spatio-temporal information contained in gas plumes. Aiming at reproducing more realistic environments, we utilize a wind tunnel with two independent gas sources that get naturally mixed along a turbulent flow. For the first time, chemo-resistive gas sensors are exposed to dynamic gas mixtures generated with several concentration levels at the sources. Moreover, the ground truth of gas concentrations at the sensor location was estimated by means of gas chromatography-mass spectrometry. We used a support vector machine as a tool to show that chemo-resistive transduction can be utilized to reliably identify chemical components in dynamic turbulent mixtures, as long as sufficient gas concentration coverage is used. We show that in open sampling systems, training the classifiers only on high concentrations of gases produces less effective classification and that it is important to calibrate the classification method with data at low gas concentrations to achieve optimal performance.

  16. Analysis of endogenous aldehydes in human urine by static headspace gas chromatography-mass spectrometry.

    Science.gov (United States)

    Serrano, María; Gallego, Mercedes; Silva, Manuel

    2016-03-11

    Endogenous aldehydes (EAs) generated during oxidative stress and cell processes are associated with many pathogenic and toxicogenic processes. The aim of this research was to develop a solvent-free and automated analytical method for the determination of EAs in human urine using a static headspace generator sampler coupled with gas chromatography-mass spectrometry (HS-GC-MS). Twelve significant EAs used as markers of different biochemical and physiological processes, namely short- and medium-chain alkanals, α,β-unsaturated aldehydes and dicarbonyl aldehydes have been selected as target analytes. Human urine samples (no dilution is required) were derivatized with O-2,3,4,5,6-pentafluorobenzylhydroxylamine in alkaline medium (hydrogen carbonate-carbonate buffer, pH 10.3). The HS-GC-MS method developed renders an efficient tool for the sensitive and precise determination of EAs in human urine with limits of detection from 1 to 15ng/L and relative standard deviations, (RSDs) from 6.0 to 7.9%. Average recoveries by enriching urine samples ranged between 92 and 95%. Aldehydes were readily determined at 0.005-50μg/L levels in human urine from healthy subjects, smokers and diabetic adults.

  17. Analysis of amphetamines and metabolites in urine with ultra performance liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Ramírez Fernández, María del Mar; Wille, Sarah M R; di Fazio, Vincent; Gosselin, Matthias; Samyn, Nele

    2010-06-01

    A simple, rapid and sensitive ultra performance liquid chromatography tandem mass spectrometry method was developed and fully validated for the quantitative determination of seven amphetamines and metabolites in urine. The method was validated for selectivity, linearity, LOQ, LOD, imprecision, bias, analyte and processed sample stability, matrix effect, recovery, carryover and dilution integrity. A classic liquid-liquid extraction with ethyl acetate was used as sample preparation procedure. The compounds were separated on an Acquity UPLC HSS C18 column in 6.8 min. The linear dynamic range was established from 25 to 500 ng/mL. The limit of quantification was fixed to the lowest calibrator level and the limit of detection ranged from 0.125 to 2.5 ng/mL. The method presented an excellent intra- and inter-assay imprecision and bias (70%) were obtained for all the compounds. No carryover was observed after the analysis of high concentrated samples (8000 ng/mL). The method was subsequently applied to authentic samples.

  18. Gas chromatography/mass spectrometry based component profiling and quality prediction for Japanese sake.

    Science.gov (United States)

    Mimura, Natsuki; Isogai, Atsuko; Iwashita, Kazuhiro; Bamba, Takeshi; Fukusaki, Eiichiro

    2014-10-01

    Sake is a Japanese traditional alcoholic beverage, which is produced by simultaneous saccharification and alcohol fermentation of polished and steamed rice by Aspergillus oryzae and Saccharomyces cerevisiae. About 300 compounds have been identified in sake, and the contribution of individual components to the sake flavor has been examined at the same time. However, only a few compounds could explain the characteristics alone and most of the attributes still remain unclear. The purpose of this study was to examine the relationship between the component profile and the attributes of sake. Gas chromatography coupled with mass spectrometry (GC/MS)-based non-targeted analysis was employed to obtain the low molecular weight component profile of Japanese sake including both nonvolatile and volatile compounds. Sake attributes and overall quality were assessed by analytical descriptive sensory test and the prediction model of the sensory score from the component profile was constructed by means of orthogonal projections to latent structures (OPLS) regression analysis. Our results showed that 12 sake attributes [ginjo-ka (aroma of premium ginjo sake), grassy/aldehydic odor, sweet aroma/caramel/burnt odor, sulfury odor, sour taste, umami, bitter taste, body, amakara (dryness), aftertaste, pungent/smoothness and appearance] and overall quality were accurately explained by component profiles. In addition, we were able to select statistically significant components according to variable importance on projection (VIP). Our methodology clarified the correlation between sake attribute and 200 low molecular components and presented the importance of each component thus, providing new insights to the flavor study of sake.

  19. [Analysis of volatile constituents in leaves of three cypress species by gas chromatography/mass spectrometry].

    Science.gov (United States)

    Hao, Dejun; Zhang, Yonghui; Dai, Huaguo; Wang, Yan

    2006-03-01

    Volatile oils in leaves of three cypress species were extracted by hydrodistillation method and analyzed by gas chromatography/mass spectrometry. Sixty-four constituents were separated and identified. The majority of the components were found to be monoterpenes and sesquiterpenes. There were 33, 37, 37 compounds in the oils of leaves of Sabina chinensis (L.) Ant, Cupressus lusitanica 'zhongshan' Mill and Sabina chinensis (L.) Ant. Cv. Kaizuca, respectively. Fourteen compounds were common to them, which were thujene, alpha-pinene, camphene, sabinene, beta-myrcene, alpha-terpinene, gamma-terpinene, alpha-terpinolene, bornyl acetate, beta-elemene, alpha-amorphene, germacrene D, delta-cadinene and elemol. In addition, each species had particular compounds. The main components were found to be: sabinene (20.99%), limonene (19.78%) and bornyl acetate (11.68%) for Sabina chinensis (L.) Ant; alpha-pinene (10.39%), sabinene (11.19%) and delta-3-carene (8.88%) for Cupressus lusitanica 'zhongshan' Mill; limonene (24.56%), beta-myrcene (8.04%) for Sabina chinensis (L.) Ant. Cv. Kaizuca.

  20. Determination of Phytochelatins in Rice by Stable Isotope Labeling Coupled with Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Liu, Ping; Cai, Wen-Jing; Yu, Lei; Yuan, Bi-Feng; Feng, Yu-Qi

    2015-07-01

    A highly sensitive method was developed for the detection of phytochelatins (PCs) in rice by stable isotope labeling coupled with liquid chromatography-electrospray ionization-tandem mass spectrometry (IL-LC-ESI-MS/MS) analysis. A pair of isotope-labeling reagents [ω-bromoacetonylquinolinium bromide (BQB) and BQB-d(7)] were used to label PCs in plant sample and standard PCs, respectively, and then combined prior to LC/MS analysis. The heavy labeled standards were used as the internal standards for quantitation to minimize the matrix and ion suppression effects in MS analysis. In addition, the ionization efficiency of PCs was greatly enhanced through the introduction of a permanent charged moiety of quaternary ammonium of BQB into PCs. The detection sensitivities of PCs upon BQB labeling improved by 14-750-fold, and therefore, PCs can be quantitated using only 5 mg of plant tissue. Furthermore, under cadmium (Cd) stress, we found that the contents of PCs in rice dramatically increased with the increased concentrations and treatment time of Cd. It was worth noting that PC5 was first identified and quantitated in rice tissues under Cd stress in the current study. Taken together, this IL-LC-ESI-MS/MS method demonstrated to be a promising strategy in detection of PCs in plants with high sensitivity and reliability.

  1. Measurement of phthalates diesters in food using gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Cariou, Ronan; Larvor, Frédéric; Monteau, Fabrice; Marchand, Philippe; Bichon, Emmanuelle; Dervilly-Pinel, Gaud; Antignac, Jean-Philippe; Le Bizec, Bruno

    2016-04-01

    An analytical strategy dedicated to 4 major phthalate diesters (DiBP, DnBP, BBzP and DEHP) monitoring in food items has been developed and validated according to normalized guidelines. The method has been applied to a wide range of foodstuffs (n=54) to generate first-ever occurrence data at the French level. This method involves separation and detection using gas chromatography coupled to tandem mass spectrometry, in electron ionisation with highly specific selected reaction monitoring, quantification being performed according to the isotope dilution principle. A particular attention has been paid to background contamination management at any stage of the analytical process, from the sampling to the expression of the results. Limits of reporting, defined as statistically different from background contamination, were found to be 2.7, 0.53, 0.18 and 3.4 μg kg(-1), and relative combined uncertainties were finally found to be 7.6%, 12.2%, 12.0% and 14.1%, for DiBP, DnBP, BBzP and DEHP, respectively.

  2. Quantitation of Thioprolines in Grape Wine by Isotope Dilution-Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Liu, Jingjing; Meng, Xiangpeng; Chan, Wan

    2016-02-17

    Cysteine reacts with reactive carbonyls to form thioprolines, which have been demonstrated to possess various pharmaceutical properties. Therefore, thioproline formation is considered as a major detoxification pathway for carcinogenic reactive carbonyls. In this study, we report the initial identification of thiazolidine-4-carboxylic acid (1) and 2-methylthiazolidine-4-carboxylic acid (2), two very common thioprolines, formed by reacting formaldehyde and acetaldehyde with cysteine in grape wine samples. We have developed an isotope dilution-liquid chromatography-tandem mass spectrometry method featuring high sensitivity (limit of detection of ≤1.5 ng/mL) and selectivity to quantitate compounds 1 and 2. The method after validated to be highly accurate (recovery of ≥92%) and precise [intraday relative standard deviation (RSD) of ≤4.1% and interday RSD of ≤9.7%] was applied to determine the varying compound 1 and 2 contents in grape wine samples. Results revealed the grape type and storage duration-dependent formation of thioprolines in grape wines. Overall, the results are expected to facilitate compound-dependent investigations of the health benefits of grape wine, and our findings could be adopted to predict the age of grape wine.

  3. [Determination of clavulanic acid residue in milk by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Yang, Gang; Huang, Xianhui; Guo, Chunna; Fang, Qiuhua; He, Limin

    2012-06-01

    An analytical method was developed for the determination of clavulanic acid (CLAV) in milk by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). A 2 g milk sample was deproteinized by ethanol. The supernatant was transferred into a pear-shaped bottle to be evaporated to about 0.5 mL, and the residue was dissolved with ammonium acetate solution. The sample was determined by HPLC-MS/MS after the purification. The chromatographic separation was achieved on a Luna 5u C8 column using 0.1% formic acid in water and acetonitrile as mobile phases with gradient elution. The identification of CLAV was carried out by MS/MS equipped with electrospray ionization in negative scanning and multiple reaction monitoring (MRM) modes. Matrix-matched calibration standard was used for the quantification. The calibration curve showed perfect linear in the range of 10 - 400 microg/kg with the correlation coefficient of 0.999. The limit of detection (LOD, S/N > or = 3) was 10 microg/kg in milk, and the limit of quantification (LOQ, S/N > or = 10) was 20 microg/kg. The mean recoveries varied from 80.00% to 91.25% at the four spiked levels of LOQ, 1/2MRL (the maximum residue limit), MRL, and 2MRL with the relative standard deviations of 5.60% -8.77%. In conclusion, the established method can be applied for the determination of CLAV residues in milk.

  4. Simultaneous liquid chromatography-mass spectrometry quantification of cefixime and clavulanic acid in human plasma.

    Science.gov (United States)

    Dubala, Anil; Nagarajan, Janaki Sankarachari Krishnan; Vimal, Chandran Sathish; George, Renjith

    2015-01-01

    A simple and specific liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS) assay method has been developed and fully validated for the simultaneous quantification of cefixime (CX) and clavulanic acid (CA) in human plasma. Analytes and internal standard were extracted from human plasma by a solid phase extraction technique using a Sam prep (3 mL, 100 mg) extraction cartridge. The extracted samples were chromatographed on a reverse phase C18 column using a mixture of methanol : acetonitrile : 2 mM ammonium acetate (pH 3.5) (25 : 25 : 50, v/v/v) as the mobile phase at a flow rate of 0.8 mL/min. Quantification of the analytes were carried out using single quadrupole LC-APCI-MS through selected ion monitoring at m/z 452 and 198, respectively, for CX and CA. The assay was linear over the concentration range of 0.05-10.0 and 0.1-10.0 μg/mL, respectively, for CX and CA. The mean plasma extraction recoveries of the CX and CA were found to be 95.20-96.27% and 94.67-95.58%, respectively. The method was successfully applied for the determination of pharmacokinetics of CX and CA after oral administration of single dosage CX/CA (200/125 mg) pill to the humans (n = 12).

  5. In situ Analysis of Organic Compounds on Mars using Chemical Derivatization and Gas Chromatography Mass Spectrometry

    Science.gov (United States)

    Glavin, D. P.; Buch, A.; Cabane, M.; Coll, P.; Navarro-Gonzalez, R.; Mahaffy, P. R.

    2005-01-01

    One of the core science objectives of NASA's 2009 Mars Science Laboratory (MSL) mission is to determine the past or present habitability of Mars. The search for key organic compounds relevant to terrestrial life will be an important part of that assessment. We have developed a protocol for the analysis of amino acids and carboxylic acids in Mars analogue materials using gas chromatography mass spectrometry (GCMS). As shown, a variety of carboxylic acids were readily identified in soil collected from the Atacama Desert in Chile at part-per-billion levels by GCMS after extraction and chemical derivatization using the reagent N,N-tert.-butyl (dimethylsilyl) trifluoroacetamide (MTBSTFA). Several derivatized amino acids including glycine and alanine were also detected by GCMS in the Atacama soil at lower concentrations (chromatogram not shown). Lacking derivatization capability, the Viking pyrolysis GCMS instruments could not have detected amino acids and carboxylic acids, since these non-volatile compounds require chemical transformation into volatile species that are stable in a GC column. We are currently optimizing the chemical extraction and derivatization technique for in situ GCMS analysis on Mars. Laboratory results of analyses of Atacama Desert samples and other Mars analogue materials using this protocol will be presented.

  6. Multi-class method for biomonitoring of hair samples using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Martín, Julia; Möder, Monika; Gaudl, Alexander; Alonso, Esteban; Reemtsma, Thorsten

    2015-11-01

    Currently, non-invasive biomonitoring of human exposure to organic pollutants bases upon the analysis mainly of urine and human breast milk. While mostly persistent organic pollutants are the center of interest, the aim of our study was to develop a method for the determination of different chemical classes of emerging pollutants (organophosphorus flame retardants, plastic additives such as phthalates, bisphenol A, insecticides, antimicrobials, preservatives and musk fragrances) in hair by gas chromatography-mass spectrometry. The preferred sample preparation included hydrolysis of the hair with trifluoroacetic acid in methanol followed by a liquid-liquid extraction using hexane/ethyl acetate. The validated method is characterized by recoveries higher than 77 % for most analytes, relative standard deviations below 16 % and limits of detection between 2 pg mg(-1) (HHCB) and 292 pg mg(-1) (propylparaben) using 50 mg of dry hair. After respective blank corrections, bis-(2-ethylhexyl)phthalate (DEHP) and the musk fragrance HHCB were the predominant compounds determined in all hair samples at concentrations between 32 and 59 ng mg(-1) and 0.8-13 ng mg(-1), respectively. The bactericide triclosan and the insect repellent N,N-diethyl-3-methylbenzamide (DEET) were detected in selected hair samples at 2 and 0.8 ng mg(-1), respectively.

  7. Characterization by Gas Chromatography-Mass Spectrometry of Commercially Available Thinner in the City of Cartagena

    Directory of Open Access Journals (Sweden)

    Jesus Olivero

    2013-09-01

    Full Text Available Thinner is a widely used product in the industry of paints, lubricants and adhesives. Its composition varies according to its use and quality. However, its chronic exposure is a concern, because it can affect major organs such as lungs, liver, kidney and the adrenal glands. This study characterizes the composition of several thinner samples commercially available in the city of Cartagena. Twelve samples were collected in different stores, these were then analyzed through gas chromatography coupled to mass spectrometry (GC/MS. The results showed that not only the composition but also the relative distribution of the components present in the samples are variable. Thirty two compounds were detected: toluene, o-xylene, p-xylene and ethylbenzene —among others— with occurrence frequencies of 91.7, 66.7, 75, and 66.7 %, respectively. The lack of knowledge regarding the risk of poisoning, produced when handling this type of mixtures, may be the cause of many health problems in people exposed to thinner, both in workplace and domestic activities. A data mining showed the potential association between thinner components and clinical manifestations, which include kidney and liver damage, hair loss, haematological disorders, dermatitis, anxiety and balance problems, among others. In conclusion, thinner has large variability, both in terms of components and of their relative composition. The adverse health effects of direct or indirect exposure to these components have been widely described in the literature.

  8. Liquid chromatography quadrupole time-of-flight mass spectrometry selective determination of ochratoxin A in wine.

    Science.gov (United States)

    Rodríguez-Cabo, T; Rodríguez, I; Ramil, M; Cela, R

    2016-05-15

    The performance of liquid chromatography quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) for ochratoxin A (OTA) determination in wine is evaluated for the first time. Sample preparation was optimized to obtain quantitative recoveries at the same time that the efficiency of electrospray ionization (ESI) remained unaltered between sample extracts and calibration standards. Under final conditions, samples (20 mL) were concentrated using a reversed-phase solid-phase extraction (SPE) cartridge, followed by OTA elution with 1 mL of ethyl acetate. The absolute recoveries of the method, established against calibration standards, were 91-121% and 90-113% (without and with internal standard correction, respectively), for wines fortified at 3 concentration levels. The attained LOQ (0.05 ng mL(-1)) remained below the maximum permitted OTA concentration (2 ng mL(-1)) in dry wines. The method was applied to different samples, with OTA being found in some dessert wines at concentrations below 1 ng mL(-1). The ethyl ester of OTA (OTC) could be identified in the same wine samples from its accurate full product ion spectra.

  9. Identification of Floral Scent in Chrysanthemum Cultivars and Wild Relatives by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Hainan Sun

    2015-03-01

    Full Text Available The objective of this study was to identify the major volatile compounds and their relative concentrations in flowers of different chrysanthemum cultivars and their wild relatives. The volatile organic components of fresh flowers were analyzed using a headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry. In total, 193 volatile organic components were detected; the major scent components were monoterpenoids and oxygenated monoterpenoids, which accounted for 68.59%–99.93% of the total volatiles in all tested materials except for Chrysanthemum indicum collected from Huangshan, in which they accounted for only 37.45% of total volatiles. The major volatile compounds were camphor, α-pinene, chrysanthenone, safranal, myrcene, eucalyptol, 2,4,5,6,7,7ab-hexahydro-1H-indene, verbenone, β-phellandrene and camphene. In a hierarchical cluster analysis, 39 accessions of Chrysanthemum and its relatives formed six clusters based on their floral volatile compounds. In a principal component analysis, only spider type flowers were located closely on the score plot. The results of this study provide a basis for breeding chrysanthemum cultivars which desirable floral scents.

  10. Validation of salivary cortisol and testosterone assays in chimpanzees by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kutsukake, Nobuyuki; Ikeda, Koki; Honma, Seijiro; Teramoto, Migaku; Mori, Yusuke; Hayasaka, Ikuo; Yamamoto, Rain; Ishida, Takafumi; Yoshikawa, Yasuhiro; Hasegawa, Toshikazu

    2009-08-01

    Owing to its high temporal sensitivity, saliva has distinct advantages for measuring steroids, compared with other noninvasive samples such as urine and feces. Here, we report the validity of assaying salivary cortisol (C) and testosterone (T) using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in captive male chimpanzees, Pan troglodytes. For both the C and T concentrations, we found positive relationships between saliva and plasma. The concentrations of C and T in saliva showed clear patterns of diurnal fluctuation, whereas those in urine and feces did not. These results suggest that the salivary steroid concentrations can be regarded as good indicators of circulating steroid levels. We also developed and validated an efficient method for collecting saliva samples from cotton rope. Although rope includes inherent steroid-like compounds and may affect the accuracy of steroid measurements, our rope-washing procedures effectively removed intrinsic steroidal materials. There was a significant association between the C and T concentrations measured from saliva collected from rope licked by the chimpanzees and those measured from saliva collected directly from the mouth. Salivary T values estimated by LC/MS-MS were similar to those measured by radioimmunoassay. The results indicate the usefulness of saliva as a noninvasive steroid measure and that steroids in the saliva of chimpanzees can be accurately measured by LC-MS/MS.

  11. Determination of tetramine in marine gastropods by liquid chromatography/electrospray ionization-mass spectrometry.

    Science.gov (United States)

    Kawashima, Yoko; Nagashima, Yuji; Shiomi, Kazuo

    2004-08-01

    Tetramine (tetramethylammonium ion) is found at high levels (several mg/g) in the salivary gland of buccinid gastropods and has been involved in numerous poisoning incidents after ingestion of those gastropods. A sensitive and selective determination method for tetramine, which is based on a combination of liquid chromatography (LC) and electrospray ionization-single quadrupole mass spectrometry (ESI-MS), was developed. Following separation by LC on a cation-exchange column, tetramine was easily detected by simultaneous monitoring of a molecular ion (m/z 74) at a cone voltage of 30 V and a fragment ion (m/z 58) at 70 V. A linear calibration curve was obtained in the range of 0.1-100 ng by plotting the peak areas of the molecular ion versus the amounts of tetramine. Spiking experiments demonstrated that tetramine in gastropod tissues can be determined by the LC/ESI-MS method, without being affected by sample matrices as well as the extration procedure. Applications of the new method to gastropod samples revealed that a small amount of tetramine is contained even in mid-gut gland and muscle and that tetramine in the salivary gland diffuses to other tissues during boiling and slow thawing.

  12. Systematic Optimization of Long Gradient Chromatography Mass Spectrometry for Deep Analysis of Brain Proteome

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hong; Yang, Yanling; Li, Yuxin; Bai, Bing; Wang, Xusheng; Tan, Haiyan; Liu, Tao; Beach, Thomas G.; Peng, Junmun; Wu, Zhiping

    2015-02-06

    Development of high resolution liquid chromatography (LC) is essential for improving the sensitivity and throughput of mass spectrometry (MS)-based proteomics. Here we present systematic optimization of a long gradient LC-MS/MS platform to enhance protein identification from a complex mixture. The platform employed an in-house fabricated, reverse phase column (100 μm x 150 cm) coupled with Q Exactive MS. The column was capable of achieving a peak capacity of approximately 700 in a 720 min gradient of 10-45% acetonitrile. The optimal loading level was about 6 micrograms of peptides, although the column allowed loading as many as 20 micrograms. Gas phase fractionation of peptide ions further increased the number of peptide identification by ~10%. Moreover, the combination of basic pH LC pre-fractionation with the long gradient LC-MS/MS platform enabled the identification of 96,127 peptides and 10,544 proteins at 1% protein false discovery rate in a postmortem brain sample of Alzheimer’s disease. As deep RNA sequencing of the same specimen suggested that ~16,000 genes were expressed, current analysis covered more than 60% of the expressed proteome. Further improvement strategies of the LC/LC-MS/MS platform were also discussed.

  13. Evaluation of column hardware on liquid chromatography-mass spectrometry of phosphorylated compounds.

    Science.gov (United States)

    Sakamaki, Hiroshi; Uchida, Takeharu; Lim, Lee Wah; Takeuchi, Toyohide

    2015-02-13

    The influences of column hardware, such as chromatographic tubes and frits, on liquid chromatography-mass spectrometry (LC-MS) analysis of phosphorylated compounds were evaluated. The signal to noise ratio (S/N) and the intensity of flavin adenine dinucleotide (FAD) using a glass lined tube and polyethylene frit (GL-PE) column was approximately 170 and 90 times higher, respectively, than those using conventional stainless steel tube and stainless steel frit (S-S) column. In addition, the retention time of FAD using GL-PE column was the shortest compared to other columns. Interaction between phosphorylated compounds and metal ions in the flow path in the S-S column was stronger than that between them and the GL-PE column. Thus, the metal ions in the flow path in GL-PE column were low. Since the specific surface area of a pair of frits was 70 times larger than that of a chromatographic tube (150 mm×2.1 mm), the frits were found to have more effective improvement of the S/N as well as the intensity than the chromatographic tubes, when phosphorylated compounds were analyzed by LC-MS. When the evaluated phosphorylated compounds were analyzed by LC-MS(/MS) using a GL-PE column, the intensity and S/N were increased.

  14. Vinegar Metabolomics: An Explorative Study of Commercial Balsamic Vinegars Using Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    Pinu, Farhana R.; de Carvalho-Silva, Samuel; Trovatti Uetanabaro, Ana Paula; Villas-Boas, Silas G.

    2016-01-01

    Balsamic vinegar is a popular food condiment produced from cooked grape must by two successive fermentation (anaerobic and aerobic) processes. Although many studies have been performed to determine the composition of major metabolites, including sugars and aroma compounds, no study has been undertaken yet to characterize the comprehensive metabolite composition of balsamic vinegars. Here, we present the first metabolomics study of commercial balsamic vinegars by gas chromatography coupled to mass spectrometry (GC-MS). The combination of three GC-MS methods allowed us to detect >1500 features in vinegar samples, of which 123 metabolites were accurately identified, including 25 amino acids, 26 carboxylic acids, 13 sugars and sugar alcohols, four fatty acids, one vitamin, one tripeptide and over 47 aroma compounds. Moreover, we identified for the first time in vinegar five volatile metabolites: acetin, 2-methylpyrazine, 2-acetyl-1-pyroline, 4-anisidine and 1,3-diacetoxypropane. Therefore, we demonstrated the capability of metabolomics for detecting and identifying large number of metabolites and some of them could be used to distinguish vinegar samples based on their origin and potentially quality. PMID:27455339

  15. [Determination of 21 fragrance allergens in toys by gas chromatography-ion trap mass spectrometry].

    Science.gov (United States)

    Lü, Qing; Zang, Qing; Bai, Hua; Li, Haiyu; Kang, Suyuan; Wang, Chao

    2012-05-01

    A method of gas chromatography-ion trap mass spectrometry (GC-IT-MS) was developed for the determination of 21 fragrance allergens in sticker toys, plush toys and plastic toys. The experimental conditions, such as sample pretreatment conditions, and the analytical conditions of GC-IT-MS, were optimized. The sticker toy samples and plush toy samples were extracted with acetone by ultrasonic wave, and the extracts were separated on an Agilent HP-1 MS column (50 m x 0.2 mm x 0.5 microm), then determined by IT-MS and quantified by external standard method. The plastic toy samples were extracted by the dissolution-precipitation approach, cleaned up with an Envi-carb solid phase extraction column and concentrated by rotary evaporation and nitrogen blowing, then determined by GC-IT-MS and quantified by external standard method. The calibration curves showed good linearity in the range of 0.002-50 mg/L with the correlation coefficients greater than 0.996 8. The limits of quantification (LOQ, S/N > 10) were 0.02-40 mg/kg. The average recoveries of the target compounds spiked in the sample at three concentration levels were in the range of 82.2%-110.8% with the relative standard deviations (RSDs) of 0.6%-10.5%. These results show that this method is accurate and sensitive for the qualitative and quantitative determination of the 21 fragrance allergens in the 3 types of toys.

  16. [Determination of five coumarins in toys by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Yang, Rongjing; Wei, Biwen; Gao, Huan; Yu, Wenjia

    2012-02-01

    A rapid analytical method for the determination of five coumarins (coumarin, 7-methoxycoumarin, dihydrocoumarin, 7-methyl coumarin and 7-ethoxy-4-methyl coumarin) in toys by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) has been developed. After ultrasonic extraction in tetrahydrofuran, the samples were analyzed by HPLC-MS/MS in multi-reaction monitoring (MRM) mode. Acetonitrile and 0.1% acetic acid were used as the mobile phases with gradient elution. The linear ranges of calibration curves were 10 - 1 000 microg/L, and the limits of quantification (LOQ) (S/N > 10) were 2.0 microg/L for all the analytes, except that the LOQ for dihydrocoumarin was 5.0 microg/L. The recoveries of the five coumarins spiked in three types of samples were in the ranges of 93.2% - 105.8%, 97.3% - 103.2% and 96.8% - 102.9%, with the relative standard deviations in the ranges of 4.35% - 8.27%, 3.65% - 6.73% and 4.03% - 6.45%, respectively. The method was applied in the determination of 12 toy samples. The five analytes were found in 9 samples, and in some cases, the presence of quite high concentrations of these coumarins in the toys should be a matter of concern.

  17. Trace level determination of acrylamide in cereal-based foods by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Pittet, Alain; Périsset, Adrienne; Oberson, Jean-Marie

    2004-04-30

    A quantitative method has been developed for the determination of trace levels (acrylamide in cereal-based foods. The method is based on extraction of acrylamide with water, acidification and purification with Carrez I and II solutions, followed by bromination of the acrylamide double bond. The reaction product (2,3-dibromopropionamide) is extracted with ethyl acetate/hexane (4:1, v/v), dried over sodium sulfate, and cleaned up through a Florisil column. The derivative is then converted to 2-bromopropenamide by dehydrobromination with triethylamine and analyzed by gas chromatography coupled to mass spectrometry (GC-MS), employing (13C3)acrylamide as internal standard. In-house validation data for commercial and experimental cereal products showed good precision of the method, with repeatability and intermediate reproducibility relative standard deviations below 10%. The limit of detection and limit of quantitation are estimated at 2 and 5 microg/kg, respectively, and recoveries of acrylamide from samples spiked at levels of 5-500 microg/kg ranged between 93 and 104% after correction of analyte loss by the internal standard. Finally, a comparative test organized with two independent laboratories provided additional confidence in the good performance of the method, particularly at very low concentration levels.

  18. [Determination of acrylamide in foods by gas chromatography-mass spectrometry].

    Science.gov (United States)

    Shen, Weijian; Shen, Chongyu; Zhao, Zengyun; Chen, Huilan; Xu, Jinzhong

    2006-11-01

    A confirmatory method is presented for the determination of acrylamide in different food products by gas chromatography-mass spectrometry (GC-MS). The method is based on the extraction of acrylamide with and methanol, and purification with Carrez I zinc sulfate) and Carrez II (potassium hexacyanoferrate) solution, followed by bromination onto the acrylamide double bond. The derivative was extracted with ethyl acetate/hexane (4: 1, v/v), and converted to the stable 2-bromopropenamide by dehydrobromination using 10% triethylamine, then analyzed by GC-MS, employing 13C3-acrylamide as internal standard. In-house validation data for flour and bread showed good accuracy and precision of the method. The recoveries of acrylamide in the French fries and bread were all in the range from 80% to 110% after correction of analyte loss by the internal standard at three spike levels of 0.02, 0.05 and 0.2 mg/kg, and relative standard deviations (RSDs) no more than 12.7%. The limits of detection for flour and bread were estimated at 5 microg/kg.

  19. Determination of fipronil by solid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Vílchez, J L; Prieto, A; Araujo, L; Navalón, A

    2001-06-01

    A method for the determination of trace amounts of the insecticide fipronil was developed using solid-phase microextraction-gas chromatography-mass spectrometry and selected ion monitoring. Fipronil was extracted with a fused-silica fiber coated with 85 microm polyacrylate. The effects of pH, ionic strength, sample volume, extraction and desorption times as well as the extraction temperature were studied. Lindane was used as an internal standard. The linear concentration range of application was 0.3-100 ng ml(-1) of fipronil, with a relative standard deviation of 9.5% (for a level of 50 ng ml(-1)) and a detection limit of 0.08 ng ml(-1). The method was applied to check the eventual existence of fipronil above this limit in water and soil samples from Granada (Spain) as well as in human urine samples. The method validation was completed with spiked matrix samples. The method can be applied as a monitoring tool for water, soil and urine, in the investigation of environmental and occupational exposure to fipronil.

  20. Impurity profiling of trinitrotoluene using vacuum-outlet gas chromatography-mass spectrometry.

    Science.gov (United States)

    Brust, Hanneke; Willemse, Sander; Zeng, Tuoyu; van Asten, Arian; Koeberg, Mattijs; van der Heijden, Antoine; Bolck, Annabel; Schoenmakers, Peter

    2014-12-29

    In this work, a reliable and robust vacuum-outlet gas chromatography-mass spectrometry (GC-MS) method is introduced for the identification and quantification of impurities in trinitrotoluene (TNT). Vacuum-outlet GC-MS allows for short analysis times; the analysis of impurities in TNT was performed in 4min. This study shows that impurity profiling of TNT can be used to investigate relations between TNT samples encountered in forensic casework. A wide variety of TNT samples were analyzed with the developed method. Dinitrobenzene, dinitrotoluene, trinitrotoluene and amino-dinitrotoluene isomers were detected at very low levels (<1wt.%) by applying the MS in selected-ion monitoring (SIM) mode. Limits of detection ranged from 6ng/mL for 2,6-dinitrotoluene to 43ng/mL for 4-amino-2,6-dinitrotoluene. Major impurities in TNT were 2,4-dinitrotoluene and 2,3,4-trinitrotoluene. Impurity profiles based on seven compounds showed to be useful to TNT samples from different sources. Statistical analysis of these impurity profiles using likelihood ratios demonstrated the potential to investigate whether two questioned TNT samples encountered in forensic casework are from the same source.

  1. Determination of Menthol in Plasma and Urine by Gas Chromatography/Mass Spectrometry (GC/MS).

    Science.gov (United States)

    Peat, Judy; Frazee, Clint; Kearns, Gregory; Garg, Uttam

    2016-01-01

    Menthol, a monoterpene, is a principal component of peppermint oil and is used extensively in consumer products as a flavoring aid. It is also commonly used medicinally as a topical skin coolant; to treat inflammation of the mucous membranes, digestive problems, and irritable bowel syndrome (IBS); and in preventing spasms during endoscopy and for its spasmolytic effect on the smooth muscle of the gastrointestinal tract. Menthol has a half life of 3-6 h and is rapidly metabolized to menthol glucuronide which is detectable in urine and serum following menthol use. We describe a method for the determination of total menthol in human plasma and urine using liquid/liquid extraction, gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring mode and menthol-d4 as the internal standard. Controls are prepared with menthol glucuronide and all samples undergo enzymatic hydrolysis for the quantification of total menthol. The method has a linear range of 5-1000 ng/mL, and coefficient of variation <10%.

  2. Hydrocarbon phenotyping of algal species using pyrolysis-gas chromatography mass spectrometry

    Directory of Open Access Journals (Sweden)

    Kothari Shankar L

    2010-05-01

    Full Text Available Abstract Background Biofuels derived from algae biomass and algae lipids might reduce dependence on fossil fuels. Existing analytical techniques need to facilitate rapid characterization of algal species by phenotyping hydrocarbon-related constituents. Results In this study, we compared the hydrocarbon rich algae Botryococcus braunii against the photoautotrophic model algae Chlamydomonas reinhardtii using pyrolysis-gas chromatography quadrupole mass spectrometry (pyGC-MS. Sequences of up to 48 dried samples can be analyzed using pyGC-MS in an automated manner without any sample preparation. Chromatograms of 30-min run times are sufficient to profile pyrolysis products from C8 to C40 carbon chain length. The freely available software tools AMDIS and SpectConnect enables straightforward data processing. In Botryococcus samples, we identified fatty acids, vitamins, sterols and fatty acid esters and several long chain hydrocarbons. The algae species C. reinhardtii, B. braunii race A and B. braunii race B were readily discriminated using their hydrocarbon phenotypes. Substructure annotation and spectral clustering yielded network graphs of similar components for visual overviews of abundant and minor constituents. Conclusion Pyrolysis-GC-MS facilitates large scale screening of hydrocarbon phenotypes for comparisons of strain differences in algae or impact of altered growth and nutrient conditions.

  3. Determination of terpenes in tequila by solid phase microextraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Peña-Alvarez, Araceli; Capella, Santiago; Juárez, Rocío; Labastida, Carmen

    2006-11-17

    Solid phase microextraction and capillary gas chromatography-mass spectrometry were used for the determination of seven terpenes in tequila. The method was selected based on the following parameters: coating selection (PA, PDMS, CW/DVB, and PDMS/DVB), extraction temperature, addition of salt, and extraction time profile. The extraction conditions were: PDMS/DVB fiber, Headspace, 100% NaCl, 25 degrees C extraction temperature, 30 min extraction time and stirring at 1200 rpm. The calibration curves (50-1000 ng/ml) for the terpenes followed linear relationships with correlation coefficients (r) greater than 0.99, except for trans,trans-farnesol (r = 0.98). RSD values were smaller than 10% confirmed that the technique was precise. Samples from 18 different trade brands of "Aged" tequila analyzed with the developed method showed the same terpenes in different concentrations. The analytical procedure used is selective, robust (more than 100 analyses with the same fiber), fast and of low-cost.

  4. Metabolism profiles of nuciferine in rats using ultrafast liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Ye, Lin-Hu; Xiao, Bing-Xin; Liao, Yong-Hong; Liu, Xin-Min; Pan, Rui-Le; Chang, Qi

    2016-08-01

    Nuciferine (NF) is one of the main aporphine alkaloids existing in the traditional Chinese medicine Folium Nelumbinis (lotus leaves). Modern pharmacological studies have demonstrated that NF has a broad spectrum of bioactivities, such as anti-HIV and anti-hyperlipidemic effects, and has been recommended as a leading compound for new drug development. However, the metabolites and biotransformation pathway of NF in vivo have not yet been comprehensively investigated. The present study was performed to identify the metabolites of NF for exploring in vivo fates. Rat plasma and urine samples were collected after oral administration and prepared by liquid-liquid extraction with ethyl acetate. A method based on ultrafast liquid chromatography with tandem mass spectrometry was applied to identify the metabolites. Q1 (first quadrupole) full scan combined with a multiple reaction monitoring (MRM) survey scan were used for the detection of metabolites. MRM-information-dependent acquisition of enhanced product ions was used for the structural identification of detected metabolites. A total of 10 metabolites were identified, including phase I (demethylation, oxidation and dehydrogenation) and phase II (glucuronidation, sulfation and glutathione) biotransformation products. Demethylation is the main metabolic pathway of NF in the body. These results can help in improving understanding of the disposition and pharmacological mechanism of NF in the body. Copyright © 2016 John Wiley & Sons, Ltd.

  5. Characterization of rhamnolipids by liquid chromatography/mass spectrometry after solid-phase extraction.

    Science.gov (United States)

    Behrens, Beate; Engelen, Jeannine; Tiso, Till; Blank, Lars Mathias; Hayen, Heiko

    2016-04-01

    Rhamnolipids are surface-active agents with a broad application potential that are produced in complex mixtures by bacteria of the genus Pseudomonas. Analysis from fermentation broth is often characterized by laborious sample preparation and requires hyphenated analytical techniques like liquid chromatography coupled to mass spectrometry (LC-MS) to obtain detailed information about sample composition. In this study, an analytical procedure based on chromatographic method development and characterization of rhamnolipid sample material by LC-MS as well as a comparison of two sample preparation methods, i.e., liquid-liquid extraction and solid-phase extraction, is presented. Efficient separation was achieved under reversed-phase conditions using a mixed propylphenyl and octadecylsilyl-modified silica gel stationary phase. LC-MS/MS analysis of a supernatant from Pseudomonas putida strain KT2440 pVLT33_rhlABC grown on glucose as sole carbon source and purified by solid-phase extraction revealed a total of 20 congeners of di-rhamnolipids, mono-rhamnolipids, and their biosynthetic precursors 3-(3-hydroxyalkanoyloxy)alkanoic acids (HAAs) with different carbon chain lengths from C8 to C14, including three rhamnolipids with uncommon C9 and C11 fatty acid residues. LC-MS and the orcinol assay were used to evaluate the developed solid-phase extraction method in comparison with the established liquid-liquid extraction. Solid-phase extraction exhibited higher yields and reproducibility as well as lower experimental effort.

  6. [Determination of gossypol in edible vegetable oil with high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Zhang, Wenhua; Huang, Chaoqun; Xie, Wen; Shen, Li

    2014-06-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of gossypol in edible vegetable oil. The sample was extracted with ethyl alcohol by vortex-excited oscillation. The extract was cleaned up by 0.22 microm filter membrane and centrifuged for 5 min at 4 000 r/min after standing in a fridge at 4 degrees C for 30 min. The compound was separated on a C18 column (100 mm x 2.1 mm, 3.5 microm) with acetonitrile and 1% (v/v) formic acid aqueous solution as mobile phase. The detection of gossypol was carried out by LC-MS/MS with positive electrospray ionization under multiple reaction monitoring (MRM) mode using external standard method. The limits of quantification (S/N > 10) of gossypol in edible vegetable oil was 1 mg/kg. The recoveries were from 87.4% to 100% at the spiked levels of 1, 2, 200 mg/kg of gossypol in edible vegetable oil with the relative standard deviations (RSDs) between 3.9% and 12.2%. The method, with high sensitivity, good precision and high recovery, was suitable for the confirmation and quantification of gossypol residue in edible vegetable oil.

  7. Determination of phthalate esters in teas and tea infusions by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Du, Liping; Ma, Lijuan; Qiao, Yang; Lu, Yan; Xiao, Dongguang

    2016-04-15

    Phthalate esters (PAEs), a group of environmental pollutants which are carcinogenic to human body, have been detected in teas. In this work, five PAEs in teas and tea infusions were quantitatively determined by a modified simultaneous distillation extraction (SDE) coupled with gas chromatography-mass spectrometry. After the optimization of SDE, the proposed method afforded a wide range of linearity and high linear regression coefficients with the limits of detection range of 0.24-3.72 μg/kg. The average recoveries were 79.83-116.67% for tea samples and 78.22-101.64% for tea infusions with all the relative standard deviations below 20%. The total content of five PAEs in teas was 1.135-3.734 mg/kg and the total dissolving ratio of five PAEs from tea to infusion was 19.05-28.07% for the selected tea samples. The risk assessment result of all the selected tea samples demonstrated that the population with the habit of drinking tea won't cause risk to human health.

  8. A strategy for identification and structural characterization of compounds from Gardenia jasminoides by integrating macroporous resin column chromatography and liquid chromatography-tandem mass spectrometry combined with ion-mobility spectrometry.

    Science.gov (United States)

    Wang, Lu; Liu, Shu; Zhang, Xueju; Xing, Junpeng; Liu, Zhiqiang; Song, Fengrui

    2016-06-24

    In this paper, an analysis strategy integrating macroporous resin (AB-8) column chromatography and high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) combined with ion mobility spectrometry (IMS) was proposed and applied for identification and structural characterization of compounds from the fruits of Gardenia jasminoides. The extracts of G. jasminoides were separated by AB-8 resin column chromatography combined with reversed phase liquid chromatography (C18 column) and detected by electrospray ionization tandem mass spectrometry. Additionally, ion mobility spectrometry (IMS) was employed as a supplementary separation technique to discover previously undetected isomers from the fruits of G. jasminoides. A total of 71 compounds, including iridoids, flavonoids, triterpenes, monoterpenoids, carotenoids and phenolic acids were identified by the characteristic high resolution mass spectrometry and the ESI-MS/MS fragmentations. In conclusion, the IMS-MS technique achieved the separation of isomers in crocin-3 and crocin-4 according to their acquired mobility drift times differing from classical analysis by mass spectrometry. The proposed strategy can be used as a highly sensitive and efficient procedure for identification and separation isomeric components in extracts of herbal medicines.

  9. Screening anti-tumor compounds from Ligusticum wallichii using cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry.

    Science.gov (United States)

    Zhang, Tao; Ding, Yuanyuan; An, Hongli; Feng, Liuxin; Wang, Sicen

    2015-07-14

    Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry was developed. Tyrosine 367 Cysteine-HEK293 cells were used as cell membrane stationary phase. Specificity and reproducibility of the cell membrane chromatography was evaluated using 1-tert-butyl-3-{2-[4-(diethylamino)butylamino]-6-(3,5-dimethoxyphenyl)pyrido[2,3-d]pyrimidin-7-yl}urea, Nimodipine and dexamethasone acetate. Then, anti-tumor components acting on Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 were screened and identified from extracts of Ligusticum wallichii. Components from the extract were retained on the cell membrane chromatographic column. The retained fraction was directly eluted into high-performance liquid chromatography with mass spectrometry system for separation and identification. Finally, Levistolide A was identified as an active component from Ligusticum wallichii extracts. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide-formazan colorimetric assay revealed that Levistolide A inhibits proliferation of overexpressing the mutated receptor cells with dose-dependent manner. Phosphorylation of fibroblast growth factor receptor 4 was also decrease under Levistolide A treatment. Flex dock simulation verified that Levistolide A could bind with the tyrosine kinase domain of fibroblast growth factor receptor 4. Therefore, Levistolide A screened by the cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry can arrest cell growth. In conclusion, the two-dimensional high-performance liquid chromatography method can screen and identify potential anti-tumor ingredients which specifically act on the tyrosine kinase domain of the mutated fibroblast growth factor receptor 4. This article is protected by copyright. All rights reserved.

  10. Analysis of allergens in tubeimu saponin extracts by using rat basophilic leukemia 2H3 cell-based affinity chromatography coupled to liquid chromatography and mass spectrometry.

    Science.gov (United States)

    Zhang, Tao; Han, Shengli; Liu, Qi; Guo, Ying; He, Langchong

    2014-11-01

    An affinity two-dimensional chromatography method was developed for the recognition, separation, and identification of allergic components from tubeimu saponin extracts, a preparation often injected to treat various conditions as indicated by traditional Chinese medicine. Rat basophilic leukemia-2H3 cell membranes were used as the stationary phase of a membrane affinity chromatography column to capture components with affinity for mast cells that could be involved in a degranulation reaction. The retained components were enriched and analyzed by membrane affinity chromatography with liquid chromatography and mass spectrometry via a port switch valve. Suitability and reliability of the method was investigated using appropriate standards, and then, the method was applied to identify components retained from tubeimu saponin extracts. Tubeimoside A was identified in this way as a potential allergen, and degranulation assays confirmed that tubeimoside A induces RBL-2H3 cell degranulation in a dose-dependent manner. An increase in Ca(2+) influx indicated that degranulation induced by tubeimoside A is likely Ca(2+) dependent. Coupled with the degranulation assay, RBL-2H3 cell-based affinity chromatography coupled with liquid chromatography and mass spectrometry is an effective method for screening and identifying allergic components from tubeimu saponin extracts.

  11. A New Liquid Chromatography-Tandem Mass Spectrometry Method for Determination of Bisoprolol in Human Plasma Samples

    Directory of Open Access Journals (Sweden)

    Gabriela Peste

    2009-01-01

    Full Text Available Liquid chromatography (LC coupled with mass spectrometry (MS detection is one of the most powerful analytical tools for organic compound analysis. The advantages of using LC/MS methods over HPLC methods include: selectivity, chromatographic integrity, peak assignment, structural information, and rapid method development. In this paper, a new liquid chromatography-tandem mass spectrometry (LC-MS/MS method has been developed and validated for the determination of bisoprolol in human plasma samples, using metoprolol as internal standard and liquid-liquid extraction procedure. The assay has proven to be sensitive, specific and reproducible, suitable to determine the bisoprolol concentration, following a single oral administration of a 10 mg bisoprolol tablet in 22 healthy volunteers, in the bioequivalence study of Bisoprolol 10 mg coated tablets, produced by Antibiotice S.A. versus Concor 10 mg, produced by Merck.

  12. Measurement of pyrethroid, organophosphorus, and carbamate insecticides in human plasma using isotope dilution gas chromatography-high resolution mass spectrometry.

    Science.gov (United States)

    Pérez, José J; Williams, Megan K; Weerasekera, Gayanga; Smith, Kimberly; Whyatt, Robin M; Needham, Larry L; Barr, Dana Boyd

    2010-10-01

    We have developed a gas chromatography-high resolution mass spectrometry method for measuring pyrethroid, organophosphorus, carbamate and fipronil pesticides and the synergist piperonyl butoxide in human plasma. Plasma samples were extracted using solid phase extraction and were then concentrated for injection and analysis using isotope dilution gas chromatography-high resolution mass spectrometry. The limits of detection ranged from 10 to 158 pg/mL with relative recoveries at concentrations near the LODs (e.g., 25 or 250 pg/mL) ranging from 87% to 156% (9 of the 16 compounds were within ±15% of 100%). The extraction recoveries ranged from 20% to 98% and the overall method relative standard deviations were typically less than 20% with some exceptions. Analytical characteristics were determined at 25, 250, and 1000 pg/mL.

  13. Rapid and Accurate Identification of Animal Species in Natural Leather Goods by Liquid Chromatography/Mass Spectrometry.

    Science.gov (United States)

    Izuchi, Yukari; Takashima, Tsuneo; Hatano, Naoya

    2016-01-01

    The demand for leather goods has grown globally in recent years. Industry revenue is forecast to reach $91.2 billion by 2018. There is an ongoing labelling problem in the leather items market, in that it is currently impossible to identify the species that a given piece of leather is derived from. To address this issue, we developed a rapid and simple method for the specific identification of leather derived from cattle, horses, pigs, sheep, goats, and deer by analysing peptides produced by the trypsin-digestion of proteins contained in leather goods using liquid chromatography/mass spectrometry. We determined species-specific amino acid sequences by liquid chromatography/tandem mass spectrometry analysis using the Mascot software program and demonstrated that collagen α-1(I), collagen α-2(I), and collagen α-1(III) from the dermal layer of the skin are particularly useful in species identification.

  14. Determination of chlorophylls and their derivatives in Gynostemma pentaphyllum Makino by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Huang, S C; Hung, C F; Wu, W B; Chen, B H

    2008-09-10

    The objectives of this study were to develop a high performance liquid chromatography-mass spectrometry (HPLC-MS) method for determination of chlorophylls and their derivatives in Gynostemma pentaphyllum Makino, a traditional Chinese herb possessing vital biological activities. Chlorophylls were extracted with a quaternary solvent system of hexane-acetone-ethanol-toluene (10:7:6:7, v/v/v/v), followed by separation of a total of 15 chlorophylls and their derivatives within 32 min using a gradient mobile phase of acetone, acetonitrile and methanol and a HyPURITY C18 column, with detection at 660 nm and flow rate at 1 mL/min. Identification was carried out on the basis of retention behavior, absorption spectra and mass spectra using atmospheric pressure chemical ionization (APCI) in positive ion mode for detection. Of the 15 analytes, chlorophyll a, chlorophyll b, pheophytin a and pheophytin b were quantified by using standard calibration curves, with the other 11 being quantified with an internal standard Fast Green FCF. Chlorophyll extracts in G. pentaphyllum were found to contain pheophytin a (2508.3 microg/g), pheophytin a' (111.2 microg/g), chlorophyll a (113.8 microg/g), chlorophyll a' (11.0 microg/g), hydroxypheophytin a (88.6 microg/g), hydroxypheophytin a' (66.5 microg/g), pyropheophytin a (76.0 microg/g), hydroxychlorophyll a (23.8 microg/g), pheophytin b (319.6 microg/g), pheophytin b' (13.2 microg/g), chlorophyll b (287.9 microg/g), chlorophyll b' (11.1 microg/g), hydroxychlorophyll b (15.0 microg/g), hydroxypheophytin b (11.2 microg/g) and hydroxypheophytin b' (8.5 microg/g).

  15. Characterization of Fumonisin A-Series by High-Resolution Liquid Chromatography-Orbitrap Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Masayoshi Tamura

    2014-08-01

    Full Text Available Fumonisin A-series (FAs in a reference material of corn sample that was naturally contaminated with fumonisins was characterized using high-resolution liquid chromatography-Orbitrap mass spectrometry (LC-Orbitap MS. Peaks for fumonisin B1 (FB1, fumonisin B2 (FB2, and fumonisin B3 (FB3, in addition to three peaks corresponding to unknown compounds I, II, and III, were detected in the chromatogram for the corn sample. Fragment ion analysis for FB1, FB2, and FB3 showed that while the ions formed at m/z values of 200–800 were similar to those formed by the cleavage of the tricarballylic acids and the hydroxyl groups, the fragmentation patterns at m/z values of 50–200 varied depending on the hydroxyl group locations in the compounds. Fragment ion analysis of compounds I–III revealed structural similarities to FBs, only differing by an additional C2H2O in the unknown compounds. Using these results and by comparing the product ion mass spectra of compound I with fumonisin A1 (FA1 synthesized from FB1 standards, compounds I–III were hypothesized to be N-acetyl analogs of FBs: fumonisins A1 (FA1, A2 (FA2, and A3 (FA3. The method for determining concentrations was validated with FA1, FB1, FB2, and FB3 standards and applied to analyze the reference material. The FB1, FB2, and FB3 analytical levels were within acceptance limits and the amount of FA1 in the material was ~15% of FB1 amount at 4.2 mg/kg.

  16. In-Depth Characterization of Protein Disulfide Bonds by Online Liquid Chromatography-Electrochemistry-Mass Spectrometry

    Science.gov (United States)

    Switzar, Linda; Nicolardi, Simone; Rutten, Julie W.; Oberstein, Saskia A. J. Lesnik; Aartsma-Rus, Annemieke; van der Burgt, Yuri E. M.

    2016-01-01

    Disulfide bonds are an important class of protein post-translational modifications, yet this structurally crucial modification type is commonly overlooked in mass spectrometry (MS)-based proteomics approaches. Recently, the benefits of online electrochemistry-assisted reduction of protein S-S bonds prior to MS analysis were exemplified by successful characterization of disulfide bonds in peptides and small proteins. In the current study, we have combined liquid chromatography (LC) with electrochemistry (EC) and mass analysis by Fourier transform ion cyclotron resonance (FTICR) MS in an online LC-EC-MS platform to characterize protein disulfide bonds in a bottom-up proteomics workflow. A key advantage of a LC-based strategy is the use of the retention time in identifying both intra- and interpeptide disulfide bonds. This is demonstrated by performing two sequential analyses of a certain protein digest, once without and once with electrochemical reduction. In this way, the "parent" disulfide-linked peptide detected in the first run has a retention time-based correlation with the EC-reduced peptides detected in the second run, thus simplifying disulfide bond mapping. Using this platform, both inter- and intra-disulfide-linked peptides were characterized in two different proteins, ß-lactoglobulin and ribonuclease B. In order to prevent disulfide reshuffling during the digestion process, proteins were digested at a relatively low pH, using (a combination of) the high specificity proteases trypsin and Glu-C. With this approach, disulfide bonds in ß-lactoglobulin and ribonuclease B were comprehensively identified and localized, showing that online LC-EC-MS is a useful tool for the characterization of protein disulfide bonds.

  17. Identification and hazard prediction of tattoo pigments by means of pyrolysis—gas chromatography/mass spectrometry

    OpenAIRE

    2016-01-01

    The implementation of regulation for tattoo ink ingredients across Europe has generated the need for analytical methods suitable to identify prohibited compounds. Common challenges of this subject are the poor solubility and the lack of volatility for most pigments and polymers applied in tattoo inks. Here, we present pyrolysis coupled to online gas chromatography and electron impact ionization mass spectrometry (py-GC/MS) as quick and reliable tool for pigment identification using both purif...

  18. Metabolite profiling of Triterpene Saponins in medicago truncatula hairy roots by liquid chromatography fourier transform Ion Cyclotron resonance mass spectrometry

    OpenAIRE

    Pollier, Jacob; Morreel, Kris; Geelen, Danny; Goossens, Alain

    2011-01-01

    Triterpenes are one of the largest classes of plant natural products, with an enormous variety in structure and bioactivities. Here, triterpene saponins from hairy roots of the model legume Medicago truncatula were profiled with reversed-phase liquid chromatography coupled to negative-ion electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (LC ESI FT-ICR MS). Owing to the accuracy of the FT-ICR MS, reliable molecular formulas of the detected compounds could be ...

  19. Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method

    OpenAIRE

    Simona Nicoara; Loris Tonidandel; Pietro Traldi; Jonathan Watson; Geraint Morgan; Ovidiu Popa

    2009-01-01

    The paper presents the application of a method based on coupled gas chromatography-mass spectrometry, using an isotopically labelled internal standard for the quantitative analysis of benzene (B), toluene (T), ethyl benzene (E), and o-, m-, p-xylenes (X). Their atmospheric concentrations were determined based on short-term sampling, in different sites of Cluj-Napoca, a highly populated urban centre in N-W Romania, with numerous and diversified road vehicles with internal combustion engines. T...

  20. Simultaneous determination of 14 β-lactam antibiotics in cosmetic products by liquid chromatography tandem mass spectrometry method

    Institute of Scientific and Technical Information of China (English)

    Cai Sheng Wu; Jin Lan Zhang; Yan Ling Qiao; Yi Lin Wang; Zhi Rong Chen

    2011-01-01

    In this study, a simple and rapid high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was established and validated to determine the 14 β-lactam antibiotics in cosmetic products, including 1 (ceftazidime), 2 (cefaclor), 3 (cefdinir), 4 (ampicillin), 5 (cefalexin), 6 (ceftezole), 7 (cefotaxim), 8 (cefradine), 9 (cefuroxime), 10 (cephazoline), 11 (cefathiamidine), 12 (cefoperazone), 13 (cafalotin), 14 (piperacillin).

  1. Selective identification and differentiation of N- and O-linked oligosaccharides in glycoproteins by liquid chromatography-mass spectrometry.

    OpenAIRE

    Carr, S. A.; Huddleston, M. J.; Bean, M. F.

    1993-01-01

    A mass spectrometry method has been developed for selective detection of glycopeptides at the low (< or = 25) picomole level during chromatography of glycoprotein digests and for differentiation of O-linked from N-linked oligosaccharides. The technique involves observation of diagnostic sugar oxonium-ion fragments, particularly the HexNAc+ fragment at m/z 204, from collisionally excited glycopeptides. Collision-induced fragmentation can be accomplished in either of two regions of a triple qua...

  2. A Gas Chromatography-Mass Spectrometry Based Study on Urine Metabolomics in Rats Chronically Poisoned with Hydrogen Sulfide

    OpenAIRE

    Mingjie Deng; Meiling Zhang; Fa Sun; Jianshe Ma; Lufeng Hu; Xuezhi Yang; Guanyang Lin; Xianqin Wang

    2015-01-01

    Gas chromatography-mass spectrometry (GS-MS) in combination with multivariate statistical analysis was applied to explore the metabolic variability in urine of chronically hydrogen sulfide- (H2S-) poisoned rats relative to control ones. The changes in endogenous metabolites were studied by partial least squares-discriminate analysis (PLS-DA) and independent-samples t-test. The metabolic patterns of H2S-poisoned group are separated from the control, suggesting that the metabolic profiles of H2...

  3. Two-Dimensional Gas Chromatography-Mass Spectrometry to Determine Composition of the Pro ducts of Waste Tire Pyrolysis

    OpenAIRE

    Gertsiuk, M.M.; Kovalchuk, T.; Kapral, K.; Lysychenko, G.V.

    2014-01-01

    The method of two-dimensional gas chromatography cou pled with mass-spectrometry detection was used for determination of pyrolysis liquid — a mixture of pyrolysis products of waste tires. 6500 organic compounds have been identified: the saturated, unsaturated, aromatic hydrocarbons, the derivatives of thiophene, cyclic aminocompounds. By its composition pyrolytic liquid is close to the diesel fuel and can be used as the alternative fuel.

  4. Two-Dimensional Gas Chromatography-Mass Spectrometry to Determine Composition of the Pro ducts of Waste Tire Pyrolysis

    Directory of Open Access Journals (Sweden)

    Gertsiuk, M.M.

    2014-03-01

    Full Text Available The method of two-dimensional gas chromatography cou pled with mass-spectrometry detection was used for determination of pyrolysis liquid — a mixture of pyrolysis products of waste tires. 6500 organic compounds have been identified: the saturated, unsaturated, aromatic hydrocarbons, the derivatives of thiophene, cyclic aminocompounds. By its composition pyrolytic liquid is close to the diesel fuel and can be used as the alternative fuel.

  5. Determining the amount of Acrylamide in Potato Chips Using Xanthydrol as a Derivative Representative with Gas Chromatography-Mass Spectrometry

    OpenAIRE

    Maryam Zokaei; Marzieh Kamankesh; Saeideh Shojaei; Abdorreza Mohammadi

    2016-01-01

    Background and Objectives: In the production process of foods rich in carbohydrates and some other foods containing precursors of acrylamide formation, there is the possibility of acrylamide creation, which is a mutagen and carcinogen material. This study aims to introduce and optimize a new method for determining acrylamide in potato chips using xanthydrol as a derivative representative with gas chromatography-mass spectrometry. Materials and Methods: Important factors in the derivatizat...

  6. Analysis of lignans in Magnoliae Flos by turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Xuan; Chen, Cen; Ye, Xiaolan; Song, Fenyun; Fan, Guorong; Wu, Fuhai

    2016-04-01

    In this study, a method coupling turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry was developed for analyzing the lignans in Magnoliae Flos. By the online pretreatment of turbulent flow chromatography solid-phase extraction, the impurities removal and analytes concentration were automatically processed, and the lignans were separated rapidly and well. Seven lignans of Magnoliae Flos including epieudesmin, magnolin, 1-irioresinol-B-dimethyl ether, epi-magnolin, fargesin aschantin, and demethoxyaschantin were identified by comparing their retention behavior, UV spectra, and mass spectra with those of reference substances or literature data. The developed method was validated, and the good results showed that the method was not only automatic and rapid, but also accurate and reliable. The turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry method holds a high potential to become an effective method for the quality control of lignans in Magnoliae Flos and a useful tool for the analysis of other complex mixtures.

  7. Application of capillary gas chromatography mass spectrometry/computer techniques to synoptic survey of organic material in bed sediment

    Science.gov (United States)

    Steinheimer, T.R.; Pereira, W.E.; Johnson, S.M.

    1981-01-01

    A bed sediment sample taken from an area impacted by heavy industrial activity was analyzed for organic compounds of environmental significance. Extraction was effected on a Soxhlet apparatus using a freeze-dried sample. The Soxhlet extract was fractionated by silica gel micro-column adsorption chromatography. Separation and identification of the organic compounds was accomplished by capillary gas chromatography/mass spectrometry techniques. More than 50 compounds were identified; these include saturated hydrocarbons, olefins, aromatic hydrocarbons, alkylated polycyclic aromatic hydrocarbons, and oxygenated compounds such as aldehydes and ketones. The role of bed sediments as a source or sink for organic pollutants is discussed. ?? 1981.

  8. A simple liquid extraction protocol for overcoming the ion suppression of triacylglycerols by phospholipids in liquid chromatography mass spectrometry studies.

    Science.gov (United States)

    Araujo, Pedro; Tilahun, Ephrem; Breivik, Joar Fjørtoft; Abdulkader, Bashir M; Frøyland, Livar; Zeng, Yingxu

    2016-02-01

    It is well-known that triacylglycerol (TAG) ions are suppressed by phospholipid (PL) ions in regiospecific analysis of TAG by mass spectrometry (MS). Hence, it is essential to remove the PL during sample preparation prior to MS analysis. The present article proposes a cost-effective liquid-liquid extraction (LLE) method to remove PL from TAG in different kinds of biological samples by using methanol, hexane and water. High performance thin layer chromatography confirmed the lack of PL in krill oil and salmon liver samples, submitted to the proposed LLE protocol, and liquid chromatography tandem MS confirmed that the identified TAG ions were highly enhanced after implementing the LLE procedure.

  9. Comparative analysis of steroidal saponins in four Dioscoreae herbs by high performance liquid chromatography coupled with mass spectrometry.

    Science.gov (United States)

    Guo, Long; Zeng, Su-Ling; Zhang, Yu; Li, Ping; Liu, E-Hu

    2016-01-01

    Steroidal saponins, which exhibit multiple pharmacological effects, are the major bioactive constituents in herbal medicines from Dioscoreae species. In this study, a sensitive method based on high performance liquid chromatography-mass spectrometry (HPLC-MS) was established and validated for qualitative and quantitative analysis of steroidal saponins in four Dioscoreae herbs including Dioscoreae Nipponica Rhizome (DNR) and Dioscoreae Hypoglaucae Rhizome (DHR), Dioscoreae Spongiosae Rhizome (DSR) and Dioscoreae Rhizome (DR). A total of eleven steroidal saponins were identified by high performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (HPLC-QTOF/MS). Furthermore, seven major steroidal saponins was simultaneous quantified using a high performance liquid chromatography coupled with triple quadrupole mass spectrometry (HPLC-QQQ/MS). The qualitative and quantitative analysis results indicated that the chemical composition of DNR, DHR and DSR samples exhibited a high level of global similarity, while the ingredients in DR varied greatly from the other three herbs. Moreover, principal component analysis (PCA) and hierarchical clustering analysis (HCA) were performed to compare and discriminate the Dioscoreae herbs based on the quantitative data. The results demonstrated the qualitative and quantitative analysis of steroidal saponins based on HPLC-MS is a feasible method for quality control of Dioscoreae herbs.

  10. Enantioselective simultaneous analysis of selected pharmaceuticals in environmental samples by ultrahigh performance supercritical fluid based chromatography tandem mass spectrometry.

    Science.gov (United States)

    Camacho-Muñoz, Dolores; Kasprzyk-Hordern, Barbara; Thomas, Kevin V

    2016-08-31

    In order to assess the true impact of each single enantiomer of pharmacologically active compounds (PACs) in the environment, highly efficient, fast and sensitive analytical methods are needed. For the first time this paper focuses on the use of ultrahigh performance supercritical fluid based chromatography coupled to a triple quadrupole mass spectrometer to develop multi-residue enantioselective methods for chiral PACs in environmental matrices. This technique exploits the advantages of supercritical fluid chromatography, ultrahigh performance liquid chromatography and mass spectrometry. Two coated modified 2.5 μm-polysaccharide-based chiral stationary phases were investigated: an amylose tris-3,5-dimethylphenylcarbamate column and a cellulose tris-3-chloro-4-methylphenylcarbamate column. The effect of different chromatographic variables on chiral recognition is highlighted. This novel approach resulted in the baseline resolution of 13 enantiomers PACs (aminorex, carprofen, chloramphenicol, 3-N-dechloroethylifosfamide, flurbiprofen, 2-hydroxyibuprofen, ifosfamide, imazalil, naproxen, ofloxacin, omeprazole, praziquantel and tetramisole) and partial resolution of 2 enantiomers PACs (ibuprofen and indoprofen) under fast-gradient conditions (supercritical fluid based chromatography coupled with tandem mass spectrometry.

  11. Profiling of lipid species by normal-phase liquid chromatography, nanoelectrospray ionization, and ion trap-orbitrap mass spectrometry

    DEFF Research Database (Denmark)

    Sokol, Elena; Almeida, Reinaldo; Hannibal-Bach, Hans Kristian

    2013-01-01

    Detailed analysis of lipid species can be challenging due to their structural diversity and wide concentration range in cells, tissues, and biofluids. To address these analytical challenges, we devised a reproducible, sensitive, and integrated lipidomics workflow based on normal-phase liquid...... chromatography-Fourier transform mass spectrometry (LC-FTMS) and LC-ITMS(2) (ion trap tandem mass spectrometry) for profiling and structural analysis of lipid species. The workflow uses a normal-phase LC system for efficient separation of apolar and polar lipid species combined with sensitive and specific...... analysis powered by a chip-based nanoelectrospray ion source and a hybrid ion trap-orbitrap mass spectrometer. The workflow was executed using a primary LC-FTMS survey routine for identification and profiling of lipid species based on high-mass accuracy and retention time followed by a targeted LC-ITMS(2...

  12. Cyclic pentapeptide analogs based on endomorphin-2 structure: cyclization studies using liquid chromatography combined with on-line mass spectrometry and tandem mass spectrometry.

    Science.gov (United States)

    Piekielna, Justyna; Kluczyk, Alicja; Perlikowska, Renata; Janecka, Anna

    2014-05-01

    The cyclization of linear analogs based on endomorphin-2 structure, Tyr/Dmt-d-Lys-Phe-Phe-Asp-NH2 and Tyr/Dmt-d-Cys-Phe-Phe-Cys-NH2 (where Dmt=2',6'-dimethyltyrosine), resulting in obtaining lactam or disulfide derivatives, was studied using liquid chromatography combined with on-line mass spectrometry (LC-MS) and tandem mass spectrometry (LC-MS/MS). In case of cyclization via an amide bond, the formation of the cyclic monomers, cyclic but not linear dimers and even traces of cyclic trimers was observed. Disulfide bridge containing peptides was obtained by the solid-phase synthesis of the linear sequences, followed by either in-solution or on-resin cyclization. In case of the in-solution cyclization, the expected cyclic monomers were the only products. When oxidation of the cysteine residues was performed when the peptides were still on the resin, cyclic monomer and two cyclodimers, parallel and antiparallel, were found. Digestion of the isolated cyclodimers with α-chymotrypsin allowed for their unambiguous identification. The comparison of the cyclic monomer/dimer ratios for analogs with Tyr versus Dmt in position 1 revealed that the presence of the exocyclic Dmt favored formation of the cyclic monomer, most likely due to the increased steric bulk of this amino acid side-chain as compared with Tyr.

  13. Metabolic Profiling with Gas Chromatography-Mass Spectrometry and Capillary Electrophoresis-Mass Spectrometry Reveals the Carbon-Nitrogen Status of Tobacco Leaves Across Different Planting Areas.

    Science.gov (United States)

    Zhao, Jieyu; Zhao, Yanni; Hu, Chunxiu; Zhao, Chunxia; Zhang, Junjie; Li, Lili; Zeng, Jun; Peng, Xiaojun; Lu, Xin; Xu, Guowang

    2016-02-05

    The interaction between carbon (C) and nitrogen (N) metabolism can reflect plant growth status and environmental factors. Little is known regarding the connections between C-N metabolism and growing regions under field conditions. To comprehensively investigate the relationship in mature tobacco leaves, we established metabolomics approaches based on gas chromatography-mass spectrometry (GC-MS) and capillary electrophoresis-time-of-flight-mass spectrometry (CE-TOF-MS). Approximately 240 polar metabolites were determined. Multivariate statistical analysis revealed that the growing region greatly influenced the metabolic profiles of tobacco leaves. A metabolic correlation network and related pathway maps were used to reveal the global overview of the alteration of C-N metabolism across three typical regions. In Yunnan, sugars and tricarboxylic acid (TCA) cycle intermediates were closely correlated with amino acid pools. Henan tobacco leaves showed positive correlation between the pentose phosphate pathway (PPP) intermediates and C-rich secondary metabolism. In Guizhou, the proline and asparagine had significant links with TCA cycle intermediates and urea cycle, and antioxidant accumulation was observed in response to drought. These results demonstrate that combined analytical approaches have great potential to detect polar metabolites and provide information on C-N metabolism related to planting regional characteristics.

  14. Characterization of phenolic amides from cortex lycii by ultra high-performance liquid chromatography coupled with LTQ-Orbitrap mass spectrometry

    Science.gov (United States)

    High performance liquid chromatography (UPLC) and flow injection electrospray ionization with ion trap mass spectrometry (FIMS) fingerprints combined with the principal component analysis (PCA) were examined for their potential in differentiating commercial organic and conventional sage samples. The...

  15. METHOD 332.0: DETERMINATION OF PERCHLORATE IN DRINKING WATER BY ION CHROMATOGRAPHY WITH SUPPRESSED CONDUCTIVITY AND ELECTROSPRAY IONIZATION MASS SPECTROMETRY

    Science.gov (United States)

    This method is applicable to the identification and quantitation of perchlorate in raw and finished drinking waters. The approach used is ion chromatography with suppressed conductivity and electrospray ionization mass spectrometry (IC-ESI/MS)

  16. Optimization of a liquid chromatography-tandem mass spectrometry method for quantification of the plant lignans secoisolariciresinol, matairesinol, lariciresinol and pinoresinol in foods

    NARCIS (Netherlands)

    Milder, I.E.J.; Arts, I.C.W.; Venema, D.P.; Lasaroms, J.J.P.; Wähälä, K.; Hollman, P.C.H.

    2004-01-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the quantification of the four major enterolignan precursors [secoisolariciresinol, matairesinol, lariciresinol, and pinoresinol] in foods. The method consists of alkaline methanolic extraction, followed by enzymati

  17. EPA Method 525.3 - Determination of Semivolatile Organic Chemicals in Drinking Water by Solid Phase Extraction and Capillary Column Gas Chromatography/Mass Spectrometry (GC/MS)

    Science.gov (United States)

    Method 525.3 is an analytical method that uses solid phase extraction (SPE) and gas chromatography/mass spectrometry (GC/MS) for the identification and quantitation of 125 selected semi-volatile organic chemicals in drinking water.

  18. Gas Chromatography and Mass Spectrometry Measurements and Protocols for Database and Library Development Relating to Organic Species in Support of the Mars Science Laboratory

    Science.gov (United States)

    Misra, P.; Garcia, R.; Mahaffy, P. R.

    2010-04-01

    An organic contaminant database and library has been developed for use with the Sample Analysis at Mars (SAM) instrumentation utilizing laboratory-based Gas Chromatography-Mass Spectrometry measurements of pyrolyzed and baked material samples.

  19. High Performance Liquid Chromatography Tandem Mass Spectrometry Assay for the Determination of Cobinamide in Pig Plasma

    Science.gov (United States)

    McCracken, Brent A.; Brittain, Matthew K.

    2015-01-01

    Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been widely utilized for the analysis of compounds in biological matrices due to its selectivity and sensitivity. This study describes the application of an LC-MS/MS-based approach toward the analysis of cobinamide in Yorkshire pig plasma. The selectivity, accuracy, precision, recovery, linearity, range, carryover, sensitivity, matrix effect, interference, stability, reproducibility, and ruggedness of the method were investigated in pig plasma. The accuracy and precision of the method was determined to be within 10% over three different days over a range of concentrations (25–10,000 ng/mL) that spanned more than two orders of magnitude. The lower limit of quantitation (LLOQ) for dicyanocobinamide was determined to be 25 ng/mL in pig plasma. Carryover was acceptable, as the area response of the carryover blanks were ≤15% of the area response of the nearest LLOQ standard for the analyte, while it was nonexistent for the internal standard. Specificity was ensured using six different lots of pig plasma. While the matrix effects of dicyanocobinamide in plasma were enhanced, ginsenoside Rb1 experienced signal suppression under the described conditions. The absolute recovery results for both compounds were consistent, precise, and reproducibly lower than expected at ~60% for dicyanocobinamide and ~22% for ginsenoside Rb1, confirming that a matrix standard curve was required for accurate quantitation. Cobinamide was shown to be very stable in matrix at various storage conditions including room temperature, refrigerated, and frozen at time intervals of 20 hours, 4 days, and 60 days respectively. This method was demonstrated to be sensitive, reproducible, stable, and rugged, and it should be applicable to the analysis of cobinamide in other biological matrices and species. PMID:26540437

  20. Validation of keratan sulfate level in mucopolysaccharidosis type IVA by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tomatsu, Shunji; Montaño, Adriana M; Oguma, Toshihiro; Dung, Vu Chi; Oikawa, Hirotaka; de Carvalho, Talita Giacomet; Gutiérrez, María L; Yamaguchi, Seiji; Suzuki, Yasuyuki; Fukushi, Masaru; Kida, Kazuhiro; Kubota, Mitsuru; Barrera, Luis; Orii, Tadao

    2010-12-01

    Mucopolysaccharidosis type IVA (MPS IVA, Morquio A disease), a progressive lysosomal storage disease, causes skeletal chondrodysplasia through excessive storage of keratan sulfate (KS). KS is synthesized mainly in cartilage and released to the circulation. The excess storage of KS disrupts cartilage, consequently releasing more KS into circulation, which is a critical biomarker for MPS IVA. Thus, assessment of KS level provides a potential screening strategy and determines clinical course and efficacy of therapies. We have recently developed a tandem mass spectrometry liquid chromatography [LC/MS/MS] method to assay KS levels in blood. Forty-nine blood specimens from patients with MPS IVA [severe (n = 33), attenuated (n = 11) and undefined (n = 5)] were analyzed for comparison of blood KS concentration with that of healthy subjects and for correlation with clinical severity. Plasma samples were digested by keratanase II to obtain disaccharides of KS. Digested samples were assayed by LC/MS/MS. We found that blood KS levels (0.4-26 µg/ml) in MPS IVA patients were significantly higher than those in age-matched controls (0.67-4.6 µg/ml; P IVA peaked between 2 years and 5 years of age (mean 11.4 µg/ml). Blood KS levels in severe MPS IVA (mean 7.3 µg/ml) were higher than in the attenuated form (mean 2.1 µg/ml) (P = 0.012). We also found elevated blood KS levels in other types of MPS. These findings indicate that the new KS assay for blood is suitable for early diagnosis and longitudinal assessment of disease severity in MPS IVA.

  1. Determination of ascorbic acid and carotenoids in food commodities by liquid chromatography with mass spectrometry detection.

    Science.gov (United States)

    Frenich, A Garrido; Torres, M E Hernández; Vega, A Belmonte; Vidal, J L Martínez; Bolaños, P Plaza

    2005-09-21

    Two methods, one to determine ascorbic acid and one to determine lycopene and beta-carotene, in vegetables and fruits by liquid chromatography coupled with mass spectrometry (LC-MS) have been established. The chromatographic separation of the studied compounds and their MS parameters were optimized to improve selectivity and sensitivity. In both methods, separation was carried out with two coupled columns, first a C(18) and then a dC(18), using as mobile phase 70% methanol (0.005% acetic acid) and 30% acetic acid 0.05% for ascorbic acid determination and a mixture of methanol, tetrahydrofuran, and acetonitrile (60:30:10 v/v/v) for carotenoid analysis in isocratic mode. The molecular ion was selected for the quantification in selective ion monitoring (SIM) mode. Ascorbic acid was detected with electrospray ionization probe (ESI) in negative mode, while chemical ionization atmospheric pressure (APCI) in positive mode was used for the target carotenoids. The methodology for ascorbic acid analysis is based on an extraction with polytron using methanol and a mixture of methaphosphoric acid and acetic acid. Extraction of the carotenoids was carried out with tetrahydrofuran/methanol (1:1) (v/v). The proposed methods were applied, after their corresponding validations, to the analysis of four varieties of tomatoes, tomato in tin enriched and dried tomato, and to the analysis of mango and kiwi fruits, to compare the content in these compounds. Moreover, the influence of the process of freezing and the effect that the manipulation/preservation has in the content of ascorbic acid in tomato have also been studied.

  2. On-line high speed lipid extraction for nanoflow liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lee, Ju Yong; Yang, Joon Seon; Park, Se Mi; Byeon, Seul Kee; Moon, Myeong Hee

    2016-09-16

    An on-line lipid extraction method is introduced by utilizing a short capillary extraction column using HILIC and C4 particles prior to nanoflow liquid chromatography-tandem mass spectrometry (nLC-MS/MS). The on-line extraction using a urine sample spiked with PL standards showed similar or slightly higher recovery values (86%-96%) of phospholipids (PLs) compared to those obtained by the conventional off-line extraction based on the Folch method with or without using the air-exposed drying process. In this study, we demonstrated that PL oxidation can occur during the air-exposed drying process of lipid extracts in standard liquid-liquid extraction procedures, which was confirmed by the oxidized PL (OxPL) molecules that were generated from an off-line extraction using a few PL standards. Quantitative comparison of these OxPL species between on- and off-line extraction followed by nLC-MS/MS with multiple reaction monitoring (MRM) analysis showed a significant decrease (2-10 fold) in unwanted OxPL species when on-line extraction was employed. While the number of identified PLs from a urine sample was somewhat lower than those by off-line extraction, the number of OxPLs was significantly reduced (from 70 to 22) with on-line extraction. The new method offers high speed (∼5min) automated extraction of PLs with nLC-MS/MS analysis and presents the possibility of handling a biological sample with a very limited amount of lipids.

  3. Extraction of pure components from overlapped signals in gas chromatography-mass spectrometry (GC-MS

    Directory of Open Access Journals (Sweden)

    Likić Vladimir A

    2009-10-01

    Full Text Available Abstract Gas chromatography-mass spectrometry (GC-MS is a widely used analytical technique for the identification and quantification of trace chemicals in complex mixtures. When complex samples are analyzed by GC-MS it is common to observe co-elution of two or more components, resulting in an overlap of signal peaks observed in the total ion chromatogram. In such situations manual signal analysis is often the most reliable means for the extraction of pure component signals; however, a systematic manual analysis over a number of samples is both tedious and prone to error. In the past 30 years a number of computational approaches were proposed to assist in the process of the extraction of pure signals from co-eluting GC-MS components. This includes empirical methods, comparison with library spectra, eigenvalue analysis, regression and others. However, to date no approach has been recognized as best, nor accepted as standard. This situation hampers general GC-MS capabilities, and in particular has implications for the development of robust, high-throughput GC-MS analytical protocols required in metabolic profiling and biomarker discovery. Here we first discuss the nature of GC-MS data, and then review some of the approaches proposed for the extraction of pure signals from co-eluting components. We summarize and classify different approaches to this problem, and examine why so many approaches proposed in the past have failed to live up to their full promise. Finally, we give some thoughts on the future developments in this field, and suggest that the progress in general computing capabilities attained in the past two decades has opened new horizons for tackling this important problem.

  4. Glass bottle sampling solid phase microextraction gas chromatography mass spectrometry for breath analysis of drug metabolites.

    Science.gov (United States)

    Lu, Yan; Niu, Wenqi; Zou, Xue; Shen, Chengyin; Xia, Lei; Huang, Chaoqun; Wang, Hongzhi; Jiang, Haihe; Chu, Yannan

    2017-03-23

    Breath analysis is a non-invasive approach which may be applied to disease diagnosis and pharmacokinetic study. In the case of offline analysis, the exhaled gas needs to be collected and the sampling bag is often used as the storage vessel. However, the sampling bag usually releases some extra compounds, which may interfere with the result of the breath test. In this study, a novel breath sampling glass bottle was developed with a syringe needle sampling port for solid phase microextraction (SPME). Such a glass bottle scarcely liberates compounds and can be used to collect exhaled gas for ensuing analysis by gas chromatography-mass spectrometry (GC-MS). The glass bottle sampling SPME-GC-MS analysis was carried out to investigate the breath metabolites of myrtol, a multicompound drug normally used in the treatment of bronchitis and sinusitis. Four compounds, α-pinene, 2,3-dehydro-1,8-cineole, d-limonene and 1,8-cineole were found in the exhaled breath of all eight volunteers who had taken the myrtol. While for other ten subjects who had not used the myrtol, these compounds were undetectable. In the SPME-GC-MS analysis of the headspace of myrtol, three compounds were detected including α-pinene, d-limonene and 1,8-cineole. Comparing the results of breath and headspace analysis, it indicates that 2,3-dehydro-1,8-cineole in the breath is the metabolite of 1,8-cineole. It is the first time that this metabolite was identified in human breath. The study demonstrates that the glass bottle sampling SPME-GC-MS method is applicable to exhaled gas analysis including breath metabolites investigation of drugs like myrtol.

  5. Detection of 36 antibiotics in coastal waters using high performance liquid chromatography-tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    NA Guangshui; GU Jia; GE Linke; ZHANG Peng; WANG Zhen; LIU Chunyang; ZHANG Lin

    2011-01-01

    Among pharmaceuticals and personal care products released into the aquatic environment,antibiotics are of particular concern,because of their ubiquity and health effects.Although scientists have recently paid more attention to the threat of antibiotics to coastal ecosystems,researchers have often focused on relatively few antibiotics,because of the absence of suitable analytical methods.We have therefore developed a method for the rapid detection of 36 antibiotic residues in coastal waters,including tetracyclines (TCs),sulfanilamides (SAs),and quinolones (QLs).The method consists of solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis,using electrospray ionization (ESI) in positive mode.The SPE was performed with Oasis HLB and Oasis MCX cartridges.Chromatographic separation on a C18 column was achieved using a binary eluent containing methanol and water with 0.1% formic acid.Typical recoveries of the analytes ranged from 67.4% to 109.3% at a fortification level of 100 ng/L.The precision of the method,calculated as relative standard deviation (RSD),was below 14.6% for all the compounds.The limits of detection (LODs) varied from 0.45 pg to 7.97 pg.The method was applied to determine the target analytes in coastal waters of the Yellow Sea in Liaoning,China.Among the tested antibiotics,31 were found in coastal waters,with their concentrations between the LOD and 212.5 ng/L.These data indicate that this method is valid for analysis of antibiotics in coastal waters.The study first reports such a large number of antibiotics along the Yellow Sea coast of Liaoning,and should facilitate future comprehensive evaluation of antibiotics in coastal ecosystems.

  6. Analysis of butadiene urinary metabolites by liquid chromatography-triple quadrupole mass spectrometry.

    Science.gov (United States)

    McDonald, Jacob D; Bechtold, William E; Krone, Jennifer R; Blackwell, Walter B; Kracko, Dean A; Henderson, Rogene F

    2004-04-01

    1,3-Butadiene (BD) is a monomer produced in petrochemical production facilities and from several combustion sources. The United States Environmental Protection Agency has defined BD as a probable human carcinogen. Methods for assessing exposure and internal dose are therefore of critical interest, and one technique is the measurement of urinary metabolites. Here we describe methods for measuring two urinary metabolites, N-acetyl-S-(3,4-dihydroxybutyl)-L-cysteine (referred to as MI) and an isomeric mixture of the regio- and stereoisomers (R)/(S)-N-acetyl-S-(1-(hydroxymethyl)-2-propen-yl)-L-cysteine and (R)/(S)-N-acetyl-S-(2-hydroxy-3-butenyl)-L-cysteine (referred to as MII). The method is based on isolation of the metabolites by solid-phase extraction and measurement using liquid chromatography and triple quadrupole mass spectrometry (LC-MS(3)). The LC-MS(3) allowed good selectivity with minimal sample preparation. Assay accuracy was within 10% or better, with substantial improvement in accuracy accompanying the commercial availability of deuterated internal standards for both compounds. Assay precision and linearity passed rigorous validation criteria, and precision-based limits of quantitation values were 12 and 1 ng/mL for MI and MII, respectively. Data are shown from analysis of human urine from occupationally exposed individuals and rat urine from BD exposures conducted to investigate rodent metabolic profiles. Both of these data sets clearly show that this assay can discern previously described relationships between BD exposure and the production of MI/MII.

  7. Role of cathode identity in liquid chromatography particle beam glow discharge mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Krishna, M.V. Balarama [Department of Chemistry, Biosystems Research Complex, Clemson University, Clemson, SC 29634-1905 (United States); Marcus, R.K. [Department of Chemistry, Biosystems Research Complex, Clemson University, Clemson, SC 29634-1905 (United States)], E-mail: marcusr@clemson.edu

    2008-06-15

    A detailed evaluation of the role of cathode identity on the analytical and spectral characteristics of various organic, organometallic and metal analytes using liquid chromatography-particle beam/glow discharge mass spectrometry (LC-PB/GDMS) has been carried out. A d.c. discharge, operating with argon as the support gas, was used throughout this work. In this study, Cu which has a relatively high sputtering rate, Ni which has moderate sputtering rate and Ta which has very low sputtering rate, are taken as cathode materials to study the ionization, fragmentation, and analytical characteristics of organic (caffeine, epigallocatechin gallate, peptide as representative compounds), organometallic (selenomethionine, triethyl lead chloride as representative compounds) and metal (Fe, La, Cs and Pb) species. A range of discharge gas pressures (26.6-106.4 Pa) and currents (0.2-1.5 mA) were investigated with the test cathodes to determine their influence on the spectral composition and overall analytical response for the various test species. Calibration plots were obtained for all of the species for each of the three cathodes to determine the respective limits of detection. Relative detection limits in the range of 0.02 to 15 ng mL{sup -1} (0.002-1.5 ng, absolute) for the test species were found to be in the order of Cu > Ni > Ta; which follows the order of the sputtering characteristics of the respective cathodes. These studies rendered information about the respective discharge parameters' role in choosing the most appropriate cathode identity in PB-GDMS for application in the areas of organic, organometallic and inorganic species analysis.

  8. Linker-assisted immunoassay and liquid chromatography/mass spectrometry for the analysis of glyphosate.

    Science.gov (United States)

    Lee, E A; Zimmerman, L R; Bhullar, B S; Thurman, E M

    2002-10-01

    A novel, sensitive, linker-assisted enzyme-linked immunosorbent assay (L'ELISA) was compared to on-line solid-phase extraction (SPE) with high-performance liquid chromatography/mass spectrometry (HPLC/MS) for the analysis of glyphosate in surface water and groundwater samples. The L'ELISA used succinic anhydride to derivatize glyphosate, which mimics the epitotic attachment of glyphosate to horseradish peroxidase hapten. Thus, L'ELISA recognized the derivatized glyphosate more effectively (detection limit of 0.1 microg/L) and with increased sensitivity (10-100 times) over conventional ELISA and showed the potential for other applications. The precision and accuracy of L'ELISA then was compared with on-line SPE/HPLC/MS, which detected glyphosate and its degradate derivatized with 9-fluorenylmethyl chloroformate using negative-ion electrospray (detection limit 0.1 microg/ L, relative standard deviation +/- 15%). Derivatization efficiency and matrix effects were minimized by adding an isotope-labeled glyphosate (2-13C15N). The accuracy of L'EUSA gave a false positive rate of 18% between 0.1 and 1.0 microg/L and a false positive rate of only 1% above 1.0 microg/L The relative standard deviation was +/- 20%. The correlation of L'ELISA and HPLC/MS for 66 surface water and groundwater samples was 0.97 with a slope of 1.28, with many detections of glyphosate and its degradate in surface water but not in groundwater.

  9. Urine Mescaline Screening With a Biochip Array Immunoassay and Quantification by Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Battal, Dilek; Barnes, Allan J; Castaneto, Marisol S; Martin, Thomas M; Klette, Kevin L; Huestis, Marilyn A

    2015-12-01

    Mescaline, the primary psychoactive chemical in peyote cactus, has been consumed for thousands of years in ancient religious ceremonies. The US military wanted to determine if mescaline intake was a problem for personnel readiness. Twenty thousand seventeen urine specimens negative for cannabinoids, cocaine, opiates, and amphetamines were tested for mescaline with the Randox Drugs of Abuse V (DOA-V) biochip array immunoassay at the manufacturer's recommended cutoff of 6 mcg/L. A sensitive and specific method for mescaline quantification in urine was developed and fully validated. Extracted analytes were derivatized with pentafluoropropionic anhydride and pentafluoropropanol and quantified by gas chromatography-mass spectrometry (GC/MS) with electron impact ionization. Standard curves, using linear least squares regression with 1/x weighting, were linear from 1 to 250 mcg/L with coefficients of determination >0.994. Intra- and inter-assay imprecision was 90.4%. Mean extraction efficiencies were >92.0% across the linear range. This fully validated method was applied for the confirmation of urinary mescaline in 526 presumptive-positive specimens and 198 randomly selected presumptive-negative specimens at the manufacturer's 6 mcg/L cutoff. No specimen confirmed positive at the GC/MS limit of quantification of 1 mcg/L. Results indicated that during this time frame, there was insufficient mescaline drug use in the military to warrant routine screening in the drug testing program. However, mescaline stability, although assessed, could have contributed to lower prevalence. We also present a validated GC/MS method for mescaline quantification in urine for reliable confirmation of suspected mescaline intake.

  10. Age determination of ballpoint pen ink by thermal desorption and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Bügler, Jürgen H; Buchner, Hans; Dallmayer, Anton

    2008-07-01

    Two main approaches can be used for determining the age of an ink: indirect dating and direct dating. Indirect dating is based on the chemical analysis of an ink followed by comparison with known samples in a reference collection. The collection should contain information about the inks including the market introduction dates. This approach may allow for an anachronism to be detected. The second concept is based on measuring ink components that change with age. The analysis of solvents in ballpoint inks may be a useful parameter for determining the age of ink on paper. In a previous study, the authors demonstrated that thermal desorption of ink directly from paper, followed by chemical analysis using gas chromatography-mass spectrometry (GC-MS), is a promising procedure for characterizing ink-binder resins and solvents. Preliminary tests showed that monitoring the evaporation of ink solvent from ink on paper is not a suitable method for ink dating. Thermal analysis of ink on paper in two steps revealed that fresh ink releases a relative amount of solvent at a certain low temperature in a defined period of time, which decreases as the ink ages. As a consequence, this relative amount of solvent released at a certain low temperature, and its decrease with time, can be used to estimate ink age. This age-dependent parameter was studied in 85 different inks ranging in age from 1 week to 1.5 years. It was found that some inks showed a significant decrease of this parameter up to an age of several months, and that the aging process can be monitored within this period. For other inks, however, the age-dependent parameter decreases relatively fast, e.g., within a few days, to a constant level, which can be too fast for casework. Based on these results, a general procedure for assessing the age of ballpoint pen inks on paper was developed.

  11. Serum metabolic profiling of human gastric cancer based on gas chromatography/mass spectrometry

    Directory of Open Access Journals (Sweden)

    Hu Song

    2012-01-01

    Full Text Available Research on molecular mechanisms of carcinogenesis plays an important role in diagnosing and treating gastric cancer. Metabolic profiling may offer the opportunity to understand the molecular mechanism of carcinogenesis and help to non-invasively identify the potential biomarkers for the early diagnosis of human gastric cancer. The aims of this study were to explore the underlying metabolic mechanisms of gastric cancer and to identify biomarkers associated with morbidity. Gas chromatography/mass spectrometry (GC/MS was used to analyze the serum metabolites of 30 Chinese gastric cancer patients and 30 healthy controls. Diagnostic models for gastric cancer were constructed using orthogonal partial least squares discriminant analysis (OPLS-DA. Acquired metabolomic data were analyzed by the nonparametric Wilcoxon test to find serum metabolic biomarkers for gastric cancer. The OPLS-DA model showed adequate discrimination between cancer and non-cancer cohorts while the model failed to discriminate different pathological stages (I-IV of gastric cancer patients. A total of 44 endogenous metabolites such as amino acids, organic acids, carbohydrates, fatty acids, and steroids were detected, of which 18 differential metabolites were identified with significant differences. A total of 13 variables were obtained for their greatest contribution in the discriminating OPLS-DA model [variable importance in the projection (VIP value >1.0], among which 11 metabolites were identified using both VIP values (VIP >1 and the Wilcoxon test. These metabolites potentially revealed perturbations of glycolysis and of amino acid, fatty acid, cholesterol, and nucleotide metabolism of gastric cancer patients. These results suggest that gastric cancer serum metabolic profiling has great potential in detecting this disease and helping to understand its metabolic mechanisms.

  12. [Determination of five pyrrolizidine alkaloids in honey by liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Lü, Chen; Ding, Tao; Ma, Xin; Chen, Guosong; Yuan, Fang; Wu, Bin; Shen, Chongyu; Zhang, Rui; Fei, Xiaoqing; Zhang, Xiaoyan; Chen, Lei; Li, Li

    2013-11-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of five pyrrolizidine alkaloids (PAs) (monocrotaline, senkirkine, retrorsine, seneciphylline and senecionine) in honey. The honey samples were dissolved in 0.1 mol/L hydrochloric acid solution and a strong-cation exchange column was used to purify and concentrate the target analytes. The separation of the analytes was carried out on a Phenomenex C18 column (100 mm x 4.6 mm, 2.6 microm) using the mobile phases of acetonitrile and 5 mmol/L ammonium acetate-0.1% (volume percentage) formic acid aqueous solution with gradient elution. The separated compounds were detected in multiple reaction monitoring (MRM) mode via positive electrospray ionization (ESI+). The calibration curves were of good linearity in the range of 1-100 microg/L (r > 0.99). The limit of quantification of the method was 1.0 microg/kg. The average recoveries were between 73.1% to 107.1% at three spiked levels (1, 20 and 50 microg/kg) with the relative standard deviations (RSDs) in the range of 4.1% to 17.0%. The proposed method was applied to different kinds of honey from China, New Zealand, Spain and Australia. The samples included rape, vitex, sunflower, cotton, tilia tree, date, acacia, buckwheat, manuka and eucalyptus honey. Monocrotaline, senkirkine and retrorsine were not detected in the collected honey samples. However, seneciphylline and senecionine were found in most of the honey samples. The concentrations of seneciphylline and senecionine were 11.0 -31.1 microg/kg and 8.3-29.1 microg/kg, respectively.

  13. Detection of stanozolol in environmental waters using liquid chromatography tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Petroczi Andrea

    2011-10-01

    Full Text Available Abstract Background Owing to frequent administration of a wide range of pharmaceutical products, various environmental waters have been found to be contaminated with pharmacologically active substances. For example, stanozolol, a synthetic anabolic steroid, is frequently misused for performance enhancement as well as for illegal growth promoting purposes in veterinary practice. Previously we reported stanozolol in hair samples collected from subjects living in Budapest. For this reason we initiated this study to explore possible environmental sources of steroid contamination. The aim of this study was to develop a method to monitor stanozolol in aqueous matrices using liquid chromatography tandem mass spectrometry (LC-MS/MS. Results Liquid-liquid extraction using pentane was found to be an efficient method for the extraction of stanozolol from water samples. This was followed by direct detection using LC-MS/MS. The method was capable of detecting 0.25 pg/mL stanozolol when only 5 mL water was processed in the presence of stanozolol D3 as internal standard. Fifteen bottled waters analysed were found to be negative for stanozolol. However, three out of six samples from the Danube river, collected from December '09 to November '10, were found to contain stanozolol at concentrations up to 1.82 pg/mL. In contrast, only one sample (out of six of urban tap water from Budapest city was found to contain stanozolol, at a concentration of 1.19 pg/mL. Conclusion The method developed is efficient, rapid, reproducible, sensitive and robust for the detection of stanozolol in aqueous matrices.

  14. Analysis of 23 polycyclic aromatic hydrocarbons in smokeless tobacco by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Stepanov, Irina; Villalta, Peter W; Knezevich, Aleksandar; Jensen, Joni; Hatsukami, Dorothy; Hecht, Stephen S

    2010-01-01

    Smokeless tobacco contains 28 known carcinogens and causes precancerous oral lesions and oral and pancreatic cancer. A recent study conducted by our research team identified eight different polycyclic aromatic hydrocarbons (PAHs) in U.S. moist snuff, encouraging further investigations of this group of toxicants and carcinogens in smokeless tobacco products. In this study, we developed a gas chromatography-mass spectrometry method that allows simultaneous analysis of 23 various PAHs in smokeless tobacco after a simple two-step extraction and purification procedure. The method produced coefficients of variation under 10% for most PAHs. The limits of quantitation for different PAHs varied between 0.3 and 11 ng/g tobacco, starting with a 300 mg sample. The recovery of the stable isotope-labeled internal standards averaged 87%. The method was applied to analysis of 23 moist snuff samples that included various flavors of the most popular U.S. moist snuff brands, as well as 17 samples representing the currently marketed brands of spit-free tobacco pouches, a relatively new type of smokeless tobacco. The sum of all detected PAHs in conventional moist snuff averaged 11.6 (+/-3.7) microg/g dry weight; 20% of this amount was comprised of carcinogenic PAHs. The levels of PAHs in new spit-free tobacco products were much lower than those in moist snuff; the sum of all detected PAHs averaged 1.3 (+/-0.28) microg/g dry weight. Our findings render PAHs one of the most prevalent groups of carcinogens in smokeless tobacco. Urgent measures are required from the U.S. tobacco industry to modify manufacturing processes so that the levels of these toxicants and carcinogens in U.S. moist snuff are greatly reduced.

  15. Linker-assisted immunoassay and liquid chromatography/mass spectrometry for the analysis of glyphosate

    Science.gov (United States)

    Lee, E.A.; Zimmerman, L.R.; Bhullar, B.S.; Thurman, E.M.

    2002-01-01

    A novel, sensitive, linker-assisted enzyme-linked immunosorbent assay (L'ELISA) was compared to on-line solidphase extraction (SPE) with high-performance liquid chromatography/mass spectrometry (HPLC/MS) for the analysis of glyphosate in surface water and groundwater samples. The L'ELISA used succinic anhydride to derivatize glyphosate, which mimics the epitotic attachment of glyphosate to horseradish peroxidase hapten. Thus, L'ELISA recognized the derivatized glyphosate more effectively (detection limit of 0.1 ??g/L) and with increased sensitivity (10-100 times) over conventional ELISA and showed the potential for other applications. The precision and accuracy of L'ELISA then was compared with on-line SPE/HPLC/MS, which detected glyphosate and its degradate derivatized with 9-fluorenylmethyl chloroformate using negative-ion electrospray (detection limit 0.1 ??g/L, relative standard deviation ??15%). Derivatization efficiency and matrix effects were minimized by adding an isotope-labeled glyphosate (2-13C15N). The accuracy of L'ELISA gave a false positive rate of 18% between 0.1 and 1.0 ??g/L and a false positive rate of only 1% above 1.0 ??g/L. The relative standard deviation was ??20%. The correlation of L'ELISA and HPLC/MS for 66 surface water and groundwater samples was 0.97 with a slope of 1.28, with many detections of glyphosate and its degradate in surface water but not in groundwater.

  16. Quantitation of Insulin Analogues in Serum Using Immunoaffinity Extraction, Liquid Chromatography, and Tandem Mass Spectrometry.

    Science.gov (United States)

    Van Der Gugten, J Grace; Wong, Sophia; Holmes, Daniel T

    2016-01-01

    Insulin analysis is used in combination with glucose, C-peptide, beta-hydroxybutyrate, and proinsulin determination for the investigation of adult hypoglycemia. The most common cause is the administration of too much insulin or insulin secretagogue to a diabetic patient or inadequate caloric intake after administration of either. Occasionally there is a question as to whether hypoglycemia has been caused by an exogenous insulin-whether by accident, intent, or even malicious intent. While traditionally this was confirmed by a low or undetectable C-peptide in a hypoglycemic specimen, this finding is not entirely specific and would also be expected in the context of impaired counter-regulatory response, fatty acid oxidation defects, and liver failure-though beta-hydroxybutyrate levels can lend diagnostic clarity. For this reason, insulin is often requested. However, popular automated chemiluminescent immunoassays for insulin have distinctly heterogeneous performance in detecting analogue synthetic insulins with cross-reactivities ranging from near 0 % to greater than 100 %. The ability to detect synthetic insulins is vendor-specific and varies between insulin products. Liquid Chromatography and Tandem Mass Spectrometry (LC-MS/MS) offers a means to circumvent these analytical issues and both quantify synthetic insulins and identify the specific type. We present an immunoaffinity extraction and LC-MS/MS method capable of independent identification and quantitation of native sequence insulins (endogenous, Insulin Regular, Insulin NPH), and analogues Glargine, Lispro, Detemir, and Aspart with an analytical sensitivity for endogenous insulin of between 1 and 2 μU/mL in patient serum samples.

  17. Simultaneous analysis of hemoglobin adducts of acrylamide and glycidamide by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Pérez, H L; Cheong, H K; Yang, J S; Osterman-Golkar, S

    1999-10-01

    Acrylamide (AA) is a carcinogen in experimental animals. Glycidamide (GA), formed by metabolic epoxidation of AA, is believed to be responsible for the carcinogenicity of AA. Occupational exposure to AA has been assessed earlier by measurement of its adducts with N-terminal valine in hemoglobin. A background of AA adducts [N-(2-carbamoylethyl)valine (AAVal), about 30 pmol/g globin] was found in individuals without known exposure to the compound. The method previously available for adducts of GA only allowed analysis of samples from highly exposed individuals and showed similar levels of AAVal and adducts of GA [N-(2-hydroxy-2-carbamoylethyl)valine (GAVal)]. We have developed a sensitive method for simultaneous quantification of adducts of GA and AA, which is suitable down to low exposure levels. The method is based on the so-called modified Edman method, where globin is reacted with pentafluorophenyl isothiocyanate under neutral conditions. The valine adducts are then extracted in the form of pentafluorophenylthiohydantoin (PFPTH) derivatives. The analytical procedure included reaction of the PFPTH derivatives with acetic anhydride in order to protect the hydroxyl group of GAVal. The PFPTH derivatives of AAVal and GAVal were analyzed by gas chromatography/tandem mass spectrometry. ((2)H(3))AAVal-PFPTH was used as the internal standard. The method was applied to samples from 11 workers at an AA production plant, 1 nonexposed nonsmoker, and a few participants of a smoking cessation program. AAVal levels were in the range 27-1854 pmol/g globin. Recorded levels of GAVal were 3-12% of those of AAVal, suggesting that previous measurements of GAVal overestimate GAVal at low levels of exposure to AA.

  18. Simultaneous quantification of Pacific ciguatoxins in fish blood using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Mak, Yim Ling; Wu, Jia Jun; Chan, Wing Hei; Murphy, Margaret B; Lam, James C W; Chan, Leo L; Lam, Paul K S

    2013-04-01

    Ciguatera fish poisoning (CFP) is a food intoxication caused by exposure to ciguatoxins (CTXs) in coral reef fish. Rapid analytical methods have been developed recently to quantify Pacific-CTX-1 (P-CTX-1) in fish muscle, but it is destructive and can cause harm to valuable live coral reef fish. Also fish muscle extract was complex making CTX quantification challenging. Not only P-CTX-1, but also P-CTX-2 and P-CTX-3 could be present in fish, contributing to ciguatoxicity. Therefore, an analytical method for simultaneous quantification of P-CTX-1, P-CTX-2, and P-CTX-3 in whole blood of marketed coral reef fish using sonication, solid-phase extraction (SPE), and liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed. The optimized method gave acceptable recoveries of P-CTXs (74-103 %) in fish blood. Matrix effects (6-26 %) in blood extracts were found to be significantly reduced compared with those in muscle extracts (suppressed by 34-75 % as reported in other studies), thereby minimizing potential for false negative results. The target P-CTXs were detectable in whole blood from four coral reef fish species collected in a CFP-endemic region. Similar trends in total P-CTX levels and patterns of P-CTX composition profiles in blood and muscle of these fish were observed, suggesting a relationship between blood and muscle levels of P-CTXs. This optimized method provides an essential tool for studies of P-CTX pharmacokinetics and pharmacodynamics in fish, which are needed for establishing the use of fish blood as a reliable sample for the assessment and control of CFP.

  19. Ovarian cancer detection from metabolomic liquid chromatography/mass spectrometry data by support vector machines

    Directory of Open Access Journals (Sweden)

    Walker L DeEtte

    2009-08-01

    Full Text Available Abstract Background The majority of ovarian cancer biomarker discovery efforts focus on the identification of proteins that can improve the predictive power of presently available diagnostic tests. We here show that metabolomics, the study of metabolic changes in biological systems, can also provide characteristic small molecule fingerprints related to this disease. Results In this work, new approaches to automatic classification of metabolomic data produced from sera of ovarian cancer patients and benign controls are investigated. The performance of support vector machines (SVM for the classification of liquid chromatography/time-of-flight mass spectrometry (LC/TOF MS metabolomic data focusing on recognizing combinations or "panels" of potential metabolic diagnostic biomarkers was evaluated. Utilizing LC/TOF MS, sera from 37 ovarian cancer patients and 35 benign controls were studied. Optimum panels of spectral features observed in positive or/and negative ion mode electrospray (ESI MS with the ability to distinguish between control and ovarian cancer samples were selected using state-of-the-art feature selection methods such as recursive feature elimination and L1-norm SVM. Conclusion Three evaluation processes (leave-one-out-cross-validation, 12-fold-cross-validation, 52-20-split-validation were used to examine the SVM models based on the selected panels in terms of their ability for differentiating control vs. disease serum samples. The statistical significance for these feature selection results were comprehensively investigated. Classification of the serum sample test set was over 90% accurate indicating promise that the above approach may lead to the development of an accurate and reliable metabolomic-based approach for detecting ovarian cancer.

  20. Human pharmacokinetics of the muscle relaxant, eperisone hydrochloride by liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Melilli, Barbara; Piazza, Cateno; Vitale, Daniela Cristina; Marano, Maria Rosa; Pecori, Andrea; Mattana, Paolo; Volsi, Valentina Li; Iuculano, Carmelo; Cardì, Francesco; Drago, Filippo

    2011-06-01

    Eperisone hydrochloride (4'-ethyl-2-methyl-3-piperidinopropiophenone hydrochloride) is a muscle relaxant agent, widely used in the treatment of patients with muscular contractures, low back pain or spasticity. Because of its mechanism of action (inhibition of gamma-efferent firing and local vasodilatation activity), side effects on central nervous system are rarely observed. A sensitive liquid chromatography-electrospray ionization-mass spectrometry method for determination of eperisone in human plasma has been developed, with a lower limit of quantification of 0.01 ng/mL. The method was applied to a pharmacokinetic study in 12 healthy volunteers given eperisone 100 mg as single dose on day 1 and three times daily on days 2 to 4. Eperisone was rapidly absorbed after oral administration (T (max) = 1.6 h) as it was expected by its fast-onset relaxant activity. Moreover, eperisone underwent a rapid elimination from the body (biological half-life 1.87 h), which was not modified during the repeated dosing as suggested by the C (max) cumulation observed, not different from that expected for a t (1/2) of 1.87 h as suggested by the similar and negligible plasma concentration values (0.063 and 0.067 ng/mL) measured on day 4 before the morning dose and 12 h after evening dose, thus ruling out any potential risk for drug accumulation. Thus, the pharmacokinetic characteristics of eperisone provide further justification for its tolerability in patients with low back pain or spastic palsy, in which the drug is given for periods ranging from few days to several months, respectively.

  1. Analysis of acetylene in blood and urine using cryogenic gas chromatography-mass spectrometry.

    Science.gov (United States)

    Kashiwagi, Masayuki; Hara, Kenji; Fujii, Hiroshi; Kageura, Mitsuyoshi; Takamoto, Mutsuo; Matsusue, Aya; Sugimura, Tomoko; Kubo, Shin-ichi

    2009-09-01

    A method for quantitative analysis of acetylene in blood and urine samples was investigated. Using cryogenic gas chromatography-mass spectrometry (GC-MS), acetylene was measured with isobutane as the internal standard in the headspace method, which revealed a linear response over the entire composite range with an excellent correlation coefficient, both in blood (R = 0.9968, range = 5.39-43.1 microg/ml) and urine (R = 0.9972, range = 2.16-10.8 microg/ml). The coefficients of variation (CV) for blood ranged from 2.62 to 11.6% for intra-day and 4.55 to 10.4% for inter-day. The CV for urine ranged from 2.38 to 3.10% for intra-day and 4.83 to 11.0% for inter-day. The recovery rate as an index of accuracy ranged from 83 to 111%. The present method showed good reliability, and is also simple and rapid. In actual samples from a charred cadaver due to acetylene explosion, the measured concentrations of acetylene by this method were 21.5 microg/ml for femoral vein blood, 17.9 microg/ml for right atrial blood, 25.5 microg/ml for left atrial blood and 7.49 microg/ml for urine. Quantification of acetylene provides important information, because the acetylene concentration is a vital reaction or sign. For example, when acetylene is filled in a closed space and then explodes, in antemortem explosion, the blood acetylene concentration of the cadaver might be significant. On the other hand, in postmortem explosion, acetylene is not detected in blood. Furthermore, when several victims are involved in one explosion, comparison of the sample concentrations can also provide useful information to establish the conditions at the accident scene; therefore, the present method is useful in forensics.

  2. Screening antiallergic components from Carthamus tinctorius using rat basophilic leukemia 2H3 cell membrane chromatography combined with high-performance liquid chromatography and tandem mass spectrometry.

    Science.gov (United States)

    Han, Shengli; Huang, Jing; Cui, Ronghua; Zhang, Tao

    2015-02-01

    Carthamus tinctorius, used in traditional Chinese medicine, has many pharmacological effects, such as anticoagulant effects, antioxidant effects, antiaging effects, regulation of gene expression, and antitumor effects. However, there is no report on the antiallergic effects of the components in C. tinctorius. In the present study, we investigated the antiallergic components of C. tinctorius and its mechanism of action. A rat basophilic leukemia 2H3/cell membrane chromatography coupled online with high-performance liquid chromatography and tandem mass spectrometry method was developed to screen antiallergic components from C. tinctorius. The screening results showed that Hydroxysafflor yellow A, from C. tinctorius, was the targeted component that retained on the rat basophilic leukemia 2H3/cell membrane chromatography column. We measured the amount of β-hexosaminidase and histamine released in mast cells and the key markers of degranulation. The release assays showed that Hydroxysafflor yellow A could attenuate the immunoglobulin E induced release of allergic cytokines without affecting cell viability from 1.0 to 50.0 μM. In conclusion, the established rat basophilic leukemia 2H3 cell membrane chromatography coupled with online high-performance liquid chromatography and tandem mass spectrometry method successfully screened and identified Hydroxysafflor yellow A from C. tinctorius as a potential antiallergic component. Pharmacological analysis elucidated that Hydroxysafflor yellow A is an effective natural component for inhibiting immunoglobulin E-antigen-mediated degranulation.

  3. Modeling RP-1 Fuel Advanced Distillation Data using Comprehensive Two-Dimensional Gas Chromatography Coupled with Time-of-Flight Mass Spectrometry and Partial Least Squares Analysis

    Science.gov (United States)

    2014-05-07

    Advanced Distillation Data using Comprehensive Two- Dimensional Gas Chromatography coupled with Time-of-Flight Mass Spectrometry and Partial Least Squares...that included comprehensive two-dimensional gas chromatography combined with time-of-flight mass spectrometry (GC × GC –TOFMS) to analyze RP-1 fuels...each RP-1 fuel with good precision and accuracy. The predictive power of the overall method via PLS modeling was assessed using leave -one-out cross

  4. Identification of triterpenoid compounds of Centella asiatica by thin-layer chromatography and mass spectrometry.

    Science.gov (United States)

    Bonfill, Mercè; Mangas, Susana; Cusidó, Rosa M; Osuna, Lidia; Piñol, M Teresa; Palazón, Javier

    2006-02-01

    The identification of the four principal triterpenoid components of Centella asiatica has been achieved by TLC on silica gel plates and mass spectrometry, as a modification of the method described in the European Pharmacopoeia (5th edn). A combination of ethyl acetate and methanol as the mobile phase was found to be successful in separating these compounds from the rest of the main components of the extract. The spots were detected with anisaldehyde solution. The separated compounds were confirmed by MALDI -TOF mass spectrometry.

  5. Review: Current applications and challenges for liquid chromatography coupled to isotope ratio mass spectrometry (LC/IRMS).

    Science.gov (United States)

    Godin, Jean-Philippe; McCullagh, James S O

    2011-10-30

    High-precision isotope analysis is recognized as an essential research tool in many fields of study. Until recently, continuous flow isotope ratio mass spectrometry (CF-IRMS) was available via an elemental analyzer or a gas chromatography inlet system for compound-specific analysis of light stable isotopes. In 2004, however, an interface that coupled liquid chromatography with IRMS (LC/IRMS) became commercially available for the first time. This brought the capability for new areas of application, in particular enabling compound-specific δ(13)C analysis of non-volatile, aqueous soluble, compounds from complex mixtures. The interface design brought with it several analytical constraints, however, in particular a lack of compatibility with certain types of chromatography as well as limited flow rates and mobile phase compositions. Routine LC/IRMS methods have, however, been established for measuring the δ(13)C isotopic ratios of underivatized individual compounds for application in archeology, nutrition and physiology, geochemistry, hydrology, soil science and food authenticity. Seven years after its introduction, we review the technical advances and constraints, methodological developments and new applications of liquid chromatography coupled to isotope ratio mass spectrometry.

  6. The use of online heart-cutting high-performance liquid chromatography coupled with linear ion trap mass spectrometry in the identification of impurities in vidarabine monophosphate.

    Science.gov (United States)

    Wang, Hang; Xu, Tongzhou; Yuan, Jiaojian

    2017-02-17

    It is difficult to identify unknown impurities in nucleotide analogues by mass spectrometry because mass-spectrometry-incompatible mobile phases need to be used to separate the major ingredient from impurities. In this study, vidarabine monophosphate was selected, and unknown impurities were identified by online heart-cutting two-dimensional high-performance liquid chromatography and linear ion trap mass spectrometry. The one-dimensional reversed-phase column was filled with a mobile phase containing nonvolatile salt. In two-dimensional high-performance liquid chromatography, we used an Acclaim Q1 column with volatile salt, and the detection wavelength was 260 nm. The mass spectrum was scanned in positive- and negative-ion mode. The online heart-cutting and online demineralization technique ensured that the mobile phase was compatible with mass spectrometry; seven impurities were identified by MS(2) and MS(3) fragments. The mass fragmentation patterns of these impurities were investigated. The two isomers were semiprepared and complemented by nuclear magnetic resonance. The results were further compared with those of normal-phase high-performance liquid chromatography with mass spectrometry. The online heart-cutting two-dimensional high-performance liquid chromatography with mass spectrometry was superior in identifying more impurities. The method solves the problem of incompatibility between the mobile phase and mass spectrometry, so it is suitable for identifying unknown impurities. This method may also be used for investigating impurities in other nucleotide analogues.

  7. Stable Isotope Labeling Strategy for Curcumin Metabolite Study in Human Liver Microsomes by Liquid Chromatography-Tandem Mass Spectrometry

    Science.gov (United States)

    Gao, Dan; Chen, Xiaowu; Yang, Xiaomei; Wu, Qin; Jin, Feng; Wen, Hongliang; Jiang, Yuyang; Liu, Hongxia

    2015-04-01

    The identification of drug metabolites is very important in drug development. Nowadays, the most widely used methods are isotopes and mass spectrometry. However, the commercial isotopic labeled reagents are usually very expensive, and the rapid and convenient identification of metabolites is still difficult. In this paper, an 18O isotope labeling strategy was developed and the isotopes were used as a tool to identify drug metabolites using mass spectrometry. Curcumin was selected as a model drug to evaluate the established method, and the 18O labeled curcumin was successfully synthesized. The non-labeled and 18O labeled curcumin were simultaneously metabolized in human liver microsomes (HLMs) and analyzed by liquid chromatography/mass spectrometry (LC-MS). The two groups of chromatograms obtained from metabolic reaction mixture with and without cofactors were compared and analyzed using Metabolynx software (Waters Corp., Milford, MA, USA). The mass spectra of the newly appearing chromatographic peaks in the experimental sample were further analyzed to find the metabolite candidates. Their chemical structures were confirmed by tandem mass spectrometry. Three metabolites, including two reduction products and a glucuronide conjugate, were successfully detected under their specific HLMs metabolic conditions, which were in accordance with the literature reported results. The results demonstrated that the developed isotope labeling method, together with post-acquisition data processing using Metabolynx software, could be used for fast identification of new drug metabolites.

  8. Liquid chromatography/mass spectrometry analysis of branched fructans produced in vitro with C-13-labeled substrates

    DEFF Research Database (Denmark)

    Verspreet, Joran; Hansen, Anders Holmgaard; Dornez, Emmie

    2014-01-01

    . Liquid chromatography/mass spectrometry (LC/MS) was used for the structural identification of branched fructans. The MS2 fragmentation of these compounds is described for the first time. Analytes were charged by electrospray ionization in negative mode and a quadrupole mass analyzer was used for MS2....... CONCLUSIONSThe MS2 fragmentation patterns described in the current paper now allow rapid screening of large sample sets for the presence of branched, graminan-type fructans. Furthermore, the data enables the characterization of fructan-metabolizing enzymes by identification of the fructan structures produced...

  9. Liquid chromatography "on-flow" 1H nuclear magnetic resonance on native glycosphingolipid mixtures together with gas chromatography/mass spectrometry on the released oligosaccharides for screening and characterisation of carbohydrate-based antigens from pig lungs.

    Science.gov (United States)

    Bäcker, A E; Thorbert, S; Rakotonirainy, O; Hallberg, E C; Olling, A; Gustavsson, M; Samuelsson, B E; Soussi, B

    1999-01-01

    Glycosphingolipids were prepared from pig lung and pooled into two fractions with (i) or = 3 sugar residues. Oligosaccharides were prepared and used for gas chromatography, gas chromatography/mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry. The glycolipid fractions i and ii were further characterised and purified using a novel method based on high performance liquid chromatography "on-flow" proton nuclear magnetic resonance. The LC "on-flow" NMR technique showed good chromatographic separation and gave NMR spectral information which could be used as guidance for pooling of the separated mixture glycolipids. Conventional 1H NMR, thin layer immunostaining, gas chromatography, gas chromatography/mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry were used to characterise the glycolipids and to validate LC-NMR spectral data.

  10. Determination of folic acid in human plasma using hydrophilic interaction chromatography-tandem mass spectrometry

    NARCIS (Netherlands)

    Garbis, S.D.; Melse-Boonstra, A.; West, C.E.; Breemen, van R.B.

    2001-01-01

    Folic acid is an essential nutrient, and folate deficiency is associated with a variety of disorders including neural tube defects (during pregnancy) and heart disease. A fast, sensitive, and robust HPLC-tandem mass spectrometry (LC-MS-MS) method was developed for the quantification of free folic ac

  11. Carbohydrate analysis of hemicelluloses by gas chromatography-mass spectrometry of acteylated methyl glycosides

    DEFF Research Database (Denmark)

    Sárossy, Zsuzsa; Plackett, David; Egsgaard, Helge

    2012-01-01

    A method based on gas chromatography–mass spectrometry analysis of acetylated methyl glycosides was developed in order to analyze monosaccharides obtained from various hemicelluloses. The derivatives of monosaccharide standards, arabinose, glucose, and xylose were studied in detail and 13C...

  12. Multiresidue analysis of pesticides in straw roughage by liquid chromatography - tandem mass spectrometry

    Science.gov (United States)

    A multiresidue analytical method using a modification of the “quick, easy, cheap, effective, rugged, and safe” (QuEChERS) sample preparation approach combined with liquid chromatography–tandem mass spectrometry (LC-MS/MS) analysis was established and validated for the rapid determination of 69 pesti...

  13. Gas chromatography mass spectrometry analysis and in vitro antibacterial activity of essential oil from Trigonella foenum-graecum

    Institute of Scientific and Technical Information of China (English)

    Moniruzzaman; Shahinuzzaman; Ahsanul; Haque; Rahima; Khatun; Zahira; Yaakob

    2015-01-01

    Objective:To evaluate the antibacterial activity of essential oil from Trigonella foenumgraecum seeds powder,and identify the compounds from the extracted oil.Methods:The seeds powder of Trigonella foenum-graecum was subjected to Clevenger extractor.Seven strains of bacteria were used to test antibacterial activity of the extract.The activity against bacteria was tested by disk diffusion method using Whatman No.1filter paper.Gas chromatography mass spectrometry analysis was performed with an Agilent7890/5975B-gas chromatography/mass selective detector.Results:The hydrodistillation of seeds powder yielded 0.285%(v/w)of oil.Disk diffusion of the oil showed bactericidal activity against both Gram negative and Gram positive bacteria of tasted strains.The inhibition zone ranged from(8±0)mm to(15.0±0.7)mm depending on microbial strains.Gas chromatography mass spectrometry analysis showed14 different compounds.The total compounds represented 80.96%of the oil.Conclusions:The antibacterial activity is due to the effects of different biological active compounds present in the extract.Identification of the compounds may help to develop new effective antimicrobial agent(s).Further researches on purification,characterization and toxicology of the active compounds are needed.

  14. Gas chromatography mass spectrometry analysis and in vitro antibacterial activity of essential oil from Trigonella foenum-graecum

    Institute of Scientific and Technical Information of China (English)

    Moniruzzaman; Shahinuzzaman; Ahsanul Haque; Rahima Khatun; Zahira Yaakob

    2015-01-01

    Objective: To evaluate the antibacterial activity of essential oil from Trigonella foenum-graecum seeds powder, and identify the compounds from the extracted oil. Methods: The seeds powder of Trigonella foenum-graecum was subjected to Clevenger extractor. Seven strains of bacteria were used to test antibacterial activity of the extract. The activity against bacteria was tested by disk diffusion method using Whatman No. 1 filter paper. Gas chromatography mass spectrometry analysis was performed with an Agilent7890/5975B-gas chromatography/mass selective detector. Results: The hydrodistillation of seeds powder yielded 0.285%(v/w) of oil. Disk diffu-sion of the oil showed bactericidal activity against both Gram negative and Gram positive bacteria of tasted strains. The inhibition zone ranged from (8 ± 0) mm to (15.0 ± 0.7) mm depending on microbial strains. Gas chromatography mass spectrometry analysis showed 14 different compounds. The total compounds represented 80.96%of the oil. Conclusions: The antibacterial activity is due to the effects of different biological active compounds present in the extract. Identification of the compounds may help to develop new effective antimicrobial agent(s). Further researches on purification, characterization and toxicology of the active compounds are needed.

  15. A Supercritical Fluid Chromatography/Tandem Mass Spectrometry Method for the Simultaneous Quantification of Metformin and Gliclazide in Human Plasma

    Science.gov (United States)

    Agrawal, Y. K.; Gogoi, P. J.; Manna, K.; Bhatt, H. G.; Jain, V. K.

    2010-01-01

    Present study reports the development and validation of a simultaneous estimation of metformin and gliclazide in human plasma using supercritical fluid chromatography followed by tandem mass spectrometry. Acetonitrile:water (80:20) mixture was used as a mobile phase along with liquid CO2 in supercritical fluid chromatography and phenformin as an internal standard. The modified plasma samples were analyzed by electro-spray ionization method in selective reaction monitoring mode in tandem mass spectrometry. Supercritical fluid chromatographic separation was performed using nucleosil C18 containing column as a stationary phase. The separated products were identified by characteristic peaks and specific fragments peaks in tandem mass spectrometry as m/z 130 to 86 for metformin, m/z 324 to 110 for gliclazide and m/z 206 to 105 for phenformin. The present method was found linear in the concentration ranges of 6.0-3550 ng/ml and 7.5-7500 ng/ml for metformin and gliclazide, respectively. Pharmacokinetic study was performed after an oral administration of dispersible tablets containing 500 mg of metformin and 80 mg of gliclazide using same techniques. PMID:20582190

  16. Analysis of flavonol glycoside isomers from leaves of Maytenus ilicifolia by offline and online high performance liquid chromatography-electrospray mass spectrometry.

    Science.gov (United States)

    de Souza, Lauro M; Cipriani, Thales R; Serrato, Rodrigo V; da Costa, Denise E; Iacomini, Marcello; Gorin, Philip A J; Sassaki, Guilherme L

    2008-10-17

    Flavonol glycosides present in leaves of Maytenus ilicifolia, were examined after fractionation on silica-gel column. Flavonol mono-, di-, tri-, and tetraglycosides, containing kaempferol, quercetin or myricetin were identified by offline electrospray mass spectrometry. Increasing the cone energy induced to adducts variation, from H(+) to Na(+). Protonated ions were characteristically fragmented by sequentially removing the monosaccharide residues, whereas in the sodiated ions, the aglycone was firstly removed. Online high performance liquid chromatography-mass spectrometry, with simple gradients of water, acetonitrile and acetic acid indicated the presence of several isomers, which were further identified by gas chromatography-mass spectrometry as containing galactose or glucose.

  17. [Determination of congo red in beef by high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry].

    Science.gov (United States)

    Lin, Hui; Xu, Chunxiang; Yan, Chunrong; Zhang, Zheng; Wang, Suilou

    2013-09-01

    A method was developed for the determination of congo red in beef. The analyte was identified by high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry (LC-QTOF MS) and quantitatively determined by ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry. After purified by liquid-liquid extraction, the congo red in the beef sample was separated on an Agilent ZORBAX Eclipse Plus C18 Rapid Resolution HD UPLC column (50 mm x 2.1 mm, 1.8 microm) HPLC , using 95% (volume percentage) methanol as the mobile phase at 0.2 mL/min. The detection was performed on an AB 4000 + triple quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operated in negative ion mode and multiple-reaction monitoring (MRM) mode. The results showed that the linear range of congo red mass concentration was 0.03 - 1 mg/L with the correlation coefficient of 0.999 8. The method had a good precision with the RSDs lower than 5% and the recoveries ranging from 88% to 91%. The limit of detection (LOD) of congo red was 0.01 mg/L. With good reproducibility, the method is simple, fast and effective for the determination of the illegally added congo red in beef and other meat products.

  18. [Rapid determination of pesticide multiresidues in porphyra by dispersive solid-phase extraction coupled with online gel permeation chromatography-gas chromatography-mass spectrometry].

    Science.gov (United States)

    Sun, Xiaojie; Guo, Mengmeng; Wang, Suyue; Tan, Zhijun; Li, Zhaoxin; Zhai, Yuxiu

    2014-10-01

    A rapid method for the simultaneous identification and quantification of pesticide multiresidues in porphyra was developed using gel permeation chromatography (GPC) coupled to gas chromatography-mass spectrometry (GPC-GC/MS). Nineteen pesticides (organochlorines, organophosphoruses, triazines and pyrethroids) were selected as the target analytes. The pretreatment method was applied consisting of organic solvent extraction followed by dispersive solid-phase extraction with graphitized carbon black (GCB) and primary secondary amine (PSA) adsorbents. GPC was also employed online to remove the large molecules such as pigments and lipids. The quantitative analysis was carried out by external standard method using gas chromatography coupled with mass spectrometry in selective ion monitoring (SIM) mode. Moreover, a large volume of sample was allowed to be injected using the program of GPC programmed-temperature vaporizer of gas chromatography to improve the sensitivity of measurements. The results showed that the calibration curves were linear (r > 0.995) in the range of 10-1,000 μg/L for all the pesticides. The limits of detection (LODs) for the pesticides in porphyra were from 0.005 to 0.03 mg/kg, and the average recoveries were between 70% and 120%. The advantages of the method are simple, sensitive and shorter operation time for analysis of pesticide residues in porphyra samples.

  19. Comparison of four mass analyzers for determining carbosulfan and its metabolites in citrus by liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Soler, Carla; Hamilton, Brett; Furey, Ambrose; James, Kevin J; Mañes, Jordi; Picó, Yolanda

    2006-01-01

    Four liquid chromatography/mass spectrometry (LC/MS) systems, equipped with single quadrupole, triple quadrupole (QqQ), quadrupole ion trap (QIT) and quadrupole time-of-flight (QqTOF) mass analyzers, were evaluated for the analysis of carbosulfan and its main transformation products. The comparison of quantitative aspects (sensitivity, precision and accuracy) was emphasized. Results showed that the triple quadrupole instrument reaches at least 20-fold higher sensitivity (LOD from 0.04 to 0.4 microg kg(-1)) compared to the single quadrupole (4-70 microg kg(-1)), the QIT (4-25 microg kg(-1)) and the QqTOF (4-23 microg kg(-1)) instruments. Recoveries were over 70% for all the analytes, except dibutylamine and 7-phenolcarbofuran. Repeatabilities (within-day) were slightly better by the single quadrupole (5-10%) and the QqQ (5-9%) than by the QIT (12-16%) and the QqTOF (9-16%). Both the QqTOF and QIT offer a linear dynamic range of two orders of magnitude whereas the single quadrupole and QqQ of, at least, three orders of magnitude. The method was applied to analyze carbosulfan field-treated orange samples, in which carbosulfan, carbofuran, 3-hydroxycarbofuran, and dibutylamine were found. As an example, the mean carbosulfan concentration was 20 +/- 0.6 microg kg(-1) measured by the QqQ, 22 +/- 1.2 microg kg(-1) by the single quadrupole, 25 +/- 2.8 microg kg(-1) by the QIT, and 20 +/- 1.8 microg kg(-1) by the QqTOF. Although the QqQ is more sensitive and precise, the mean values obtained by the four instruments are acceptable and comparable. The potential of each technique for the verification of the identity of residues detected in oranges is discussed using the concept of identification points.

  20. Comprehensive multidimensional gas chromatography coupled to low resolution quadrupole mass spectrometry for the analysis of PCDDs, PCDFs and PCBs

    Energy Technology Data Exchange (ETDEWEB)

    Costa, J.P. [Universitat de Barcelona (Spain). Facultat de Quimica, Dept. de Quimica Analitica; Korytar, P.; Boer, J. de [Netherlands Institutes for Fisheries Research, Ijmuiden (Netherlands); Leonards, P. [Instituto Quimico de Sarria, Barcelona (Spain)

    2004-09-15

    Because of the high persistency and extreme toxicity of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) and so-called dioxin-like polychlorinated biphenyls (PCBs), their trace level determination is a topic of much interest. The typical concentrations of this compounds, sub-ng/kg, makes that they have to be clearly separated from other, less toxic, congeners present in the samples and from the matrix and the use of sensitive techniques is required for the quantification. The analyses of the compounds are usually done by high resolution gas chromatography coupled to high resolution mass spectrometry (HRGC-HRMS). Recently, alternative novel techniques have been developed which are improving the chromatographic separation, e.g. comprehensive multidimensional gas chromatography (GC x GC), for the analysis of the compounds. The aim of this work is to evaluate GC x GC coupled to a low resolution quadrupole mass spectrometer for the quantification of PCDDs, PCDFs and dioxin like PCBs.

  1. Detecting Organic Compounds in Martian Soil Analogues Using Gas Chromatography Mass Spectrometry

    Science.gov (United States)

    Glavin, D. P.; Buch, A.; Mahaffy, P. R.

    2004-01-01

    One of the primary objectives of the 1976 Viking missions was to determine whether organic compounds, possibly of biological origin, were present in the Martian surface soils. The Viking gas chromatography mass spectrometry (GCMS) instruments found no evidence for any organic compounds of Martian origin above a few parts per billion in the upper 10 cm of surface soil [l], suggesting the absence of a widely distributed Martian biota. However, Benner et d. have suggested that significant amounts of non-volatile organic compounds, possibly including oxidation products of bioorganic molecules (e.g. carboxylic acids) would not have been detected by the Viking GCMS [2]. Moreover, other key organic compounds important to biology, such as amino acids and nucleobases, would also likely have been missed by the Viking GCMS as these compounds require chemical derivatization to be stable in a GC column [3]. Recent pyrolysis experiments with a Mars soil analogue that had been innoculated with Escherichia coli bacteria have shown that amino acid decomposition products (amines) and nucleobases are among the most abundant products generated after pyrolysis of the bacterial cells [4,5]. At the part per billion level (Viking GCMS detection limit), these pyrolysis products generated from several million bacterial cells per gram of Martian soil would not have been detected by the Viking GCMS instruments [4]. Analytical protocols are under development for upcoming in situ lander opportunities to target several important biological compounds including amino acids and nucleobases. For example, extraction and chemical derivatization techniques [3] are being adapted for space flight use to transform reactive or fragile molecules that would not have been detected by the Viking GCMS instruments, into species that are sufficiently volatile to be detected by GCMS. Recent experiments carried out at NASA Goddard have shown that using this derivatization technique all of the targeted compounds

  2. Quantification of Neurotransmitters in Mouse Brain Tissue by Using Liquid Chromatography Coupled Electrospray Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Tae-Hyun Kim

    2014-01-01

    Full Text Available A simple and rapid liquid chromatography tandem mass spectrometry method has been developed for the determination of BH4, DA, 5-HT, NE, EP, Glu, and GABA in mouse brain using epsilon-acetamidocaproic acid and isotopically labeled neurotransmitters as internal standards. Proteins in the samples were precipitated by adding acetonitrile, and then the supernatants were separated by a Sepax Polar-Imidazole (2.1 mm × 100 mm, i.d., 3 μm column by adding a mixture of 10 mM ammonium formate in acetonitrile/water (75 : 25, v/v, 300 μl/min for BH4 and DA. To assay 5-HT, NE, EP, Glu, and GABA; a Luna 3 μ C18 (3.0 mm × 150 mm, i.d., 3 μm column was used by adding a mixture of 1% formic acid in acetonitrile/water (20 : 80, v/v, 350 μl/min. The total chromatographic run time was 5.5 min. The method was validated for the analysis of samples. The calibration curve was linear between 10 and 2000 ng/g for BH4 r2=0.995, 10 and 5000 ng/g for DA r2=0.997, 20 and 10000 ng/g for 5-HT r2=0.994, NE r2=0.993, and EP r2=0.993, and 0.2 and 200 μg/g for Glu r2=0.996 and GABA r2=0.999 in the mouse brain tissues. As stated above, LC-MS/MS results were obtained and established to be a useful tool for the quantitative analysis of BH4, DA, 5-HT, NE, EP, Glu, and GABA in the experimental rodent brain.

  3. Dansylation isotope labeling liquid chromatography mass spectrometry for parallel profiling of human urinary and fecal submetabolomes

    Energy Technology Data Exchange (ETDEWEB)

    Su, Xiaoling [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Wang, Nan [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2 (Canada); Chen, Deying [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Li, Yunong [Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2 (Canada); Lu, Yingfeng [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Huan, Tao [Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2 (Canada); Xu, Wei [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Li, Liang, E-mail: Liang.Li@ualberta.ca [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2 (Canada); Li, Lanjuan, E-mail: ljli@zju.edu.cn [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China)

    2016-01-15

    Human urine and feces can be non-invasively collected for metabolomics-based disease biomarker discovery research. Because urinary and fecal metabolomes are thought to be different, analysis of both biospecimens may generate a more comprehensive metabolomic profile that can be better related to the health state of an individual. Herein we describe a method of using differential chemical isotope labeling (CIL) liquid chromatography mass spectrometry (LC-MS) for parallel metabolomic profiling of urine and feces. Dansylation labeling was used to quantify the amine/phenol submetabolome changes among different samples based on {sup 12}C-labeling of individual samples and {sup 13}C-labeling of a pooled urine or pooled feces and subsequent analysis of the {sup 13}C-/{sup 12}C-labeled mixture by LC-MS. The pooled urine and pooled feces are further differentially labeled, mixed and then analyzed by LC-MS in order to relate the metabolite concentrations of the common metabolites found in both biospecimens. This method offers a means of direct comparison of urinary and fecal submetabolomes. We evaluated the analytical performance and demonstrated the utility of this method in the analysis of urine and feces collected daily from three healthy individuals for 7 days. On average, 2534 ± 113 (n = 126) peak pairs or metabolites could be detected from a urine sample, while 2507 ± 77 (n = 63) peak pairs were detected from a fecal sample. In total, 5372 unique peak pairs were detected from all the samples combined; 3089 and 3012 pairs were found in urine and feces, respectively. These results reveal that the urine and fecal metabolomes are very different, thereby justifying the consideration of using both biospecimens to increase the probability of finding specific biomarkers of diseases. Furthermore, the CIL LC-MS method described can be used to perform parallel quantitative analysis of urine and feces, resulting in more complete coverage of the human metabolome

  4. Evaluation of propolis polyphenols absorption in humans by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Gardana, Claudio; Simonetti, Paolo; Berti, Cristiana; Pietta, Piergiorgio

    2007-01-01

    Propolis has various biological activities such as antibacterial, antiviral, antioxidant, immunostimulating and antiinflammatory, which are generally ascribed to the polyphenolic fraction. The aim of this study was to evaluate the absorption of the main polyphenols [caffeic acid (CA), pinobanksin-5methyl ether (P-5ME), pinobanksin (Pb), chrysin (C), pinocembrin (P), galangin (G), pinobanksin-3-acetate, pinobanksin esters and caffeic acid phenylethyl ester (CAPE)] from a dewaxed and standardized extract of propolis (EPID). Fifteen healthy volunteers consumed 5 mL EPID in water, corresponding to 125 mg of flavonoids. Blood samples were collected before, each hour for 8 h and 24 h after EPID intake. After deconjugation by beta-glucuronidase/sulfatase the plasma samples were analyzed by a selective liquid chromatography/tandem mass spectrometry (LC/MS/MS) method using morin as internal standard (I.S.). A kinetic profile characterized by two t(max), respectively at 1 h and about 5 h post-ingestion, was observed in all the subjects. The two peaks may be due to enterohepatic cycling. Among the various polyphenols ingested, only P-5ME, Pb, C, P and G were detected in plasma and C(max)t(1h) were 65.7 +/- 13.3, 46.5 +/- 12.7, 79.5 +/- 18.6, 168.1 +/- 16.3 and 113.7 +/- 16.8 ng/mL, respectively. These levels decreased significantly after 8 h and were no longer detectable 24 h after EPID intake. The recovery of the extraction for CA, Pb, C, P, G and I.S. from spiked plasma was 95.2 +/- 3.1, 93.1 +/- 3.6, 91 +/- 2.5, 96.4 +/- 4.2, 93.4 +/- 2.4 and 85.5 +/- 2.4%, respectively. The results of this study evidence that flavonoids from EPID are absorbed, metabolized and Pb-5ME and G seem to have apparent absorption, measured as (AUC/dose), higher than C, P and Pb.

  5. Detecting Organic Compounds in Martian Soil Analogues Using Gas Chromatography Mass Spectrometry

    Science.gov (United States)

    Glavin, D. P.; Buch, A.; Mahaffy, P. R.

    2004-01-01

    One of the primary objectives of the 1976 Viking missions was to determine whether organic compounds, possibly of biological origin, were present in the Martian surface soils. The Viking gas chromatography mass spectrometry (GCMS) instruments found no evidence for any organic compounds of Martian origin above a few parts per billion in the upper 10 cm of surface soil [l], suggesting the absence of a widely distributed Martian biota. However, Benner et d. have suggested that significant amounts of non-volatile organic compounds, possibly including oxidation products of bioorganic molecules (e.g. carboxylic acids) would not have been detected by the Viking GCMS [2]. Moreover, other key organic compounds important to biology, such as amino acids and nucleobases, would also likely have been missed by the Viking GCMS as these compounds require chemical derivatization to be stable in a GC column [3]. Recent pyrolysis experiments with a Mars soil analogue that had been innoculated with Escherichia coli bacteria have shown that amino acid decomposition products (amines) and nucleobases are among the most abundant products generated after pyrolysis of the bacterial cells [4,5]. At the part per billion level (Viking GCMS detection limit), these pyrolysis products generated from several million bacterial cells per gram of Martian soil would not have been detected by the Viking GCMS instruments [4]. Analytical protocols are under development for upcoming in situ lander opportunities to target several important biological compounds including amino acids and nucleobases. For example, extraction and chemical derivatization techniques [3] are being adapted for space flight use to transform reactive or fragile molecules that would not have been detected by the Viking GCMS instruments, into species that are sufficiently volatile to be detected by GCMS. Recent experiments carried out at NASA Goddard have shown that using this derivatization technique all of the targeted compounds

  6. Characterization of phosphoproteins from electrophoretic gels by nanoscale Fe(III) affinity chromatography with off-line mass spectrometry analysis

    DEFF Research Database (Denmark)

    Stensballe, A; Andersen, Søren; Jensen, Ole Nørregaard

    2001-01-01

    Detailed characterization of phosphoproteins as well as other post-translationally modified proteins is required to fully understand protein function and regulatory events in cells and organisms. Here we present a mass spectrometry (MS) based experimental strategy for the identification and mapping...... chromatography (Fe(III)-IMAC) columns were employed for enrichment of phosphorylated peptides from crude peptide mixtures prior to off-line analysis by matrix-assisted laser desorption/ionization (MALDI) MS or nanoelectrospray tandem mass spectrometry (MS/MS). An optimized and sensitive procedure for alkaline...... of phosphorylation sites. The advantages and limitations of the experimental strategy was demonstrated by enrichment, identification and sequencing of phosphopeptides from the model proteins ovalbumin and bovine beta-casein isolated by gel electrophoresis. Furthermore, an autophosphorylation site at Ser-3...

  7. Identification of phosphorylation sites of proteins by high performance liquid chromatography-electrospray ionization-quadrupole ion trap mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The phosphorylation sites of two phosphorylated proteins, bovine b-casein and myelin basic protein (MBP), were identified by high performance liquid chromatography-electrospray ionization-quadrupole ion trap mass spectrometry (HPLC-ESI-QITMS). The tryptic digest of each protein was separated by HPLC, the molecular weight of each peptide was determined by ESI-QITMS on line, and MS/MS spectrum of each peptide was simultaneously obtained by the combination of collision-induced desorption (CID) technique and tandem mass spectrometry (MS/MS) of QITMS. The phosphorylated peptide was identified by looking into whether the difference between the observed and predicted molecular weights of a peptide is 80 u or its integral multiple. Then the phosphorylation site was identified through manual interpretation of the MS/MS spectrum of the phosphorylated peptide or automatic SEQUEST data base-searching.

  8. Identification of phosphorylation sites of proteins by high performance liquid chromatography-electrospray ionization-quadrupole ion trap mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    车发云; 邵晓霞; 夏其昌

    2000-01-01

    The phosphorylation sites of two phosphorylated proteins, bovine β-casein and myelin basic protein (MBP), were identified by high performance liquid chromatography-electrospray ionization-quadrupole ion trap mass spectrometry (HPLC-ESI-QITMS). The tryptic digest of each protein was separated by HPLC, the molecular weight of each peptide was determined by ESI-QITMS on line, and MS/MS spectrum of each peptide was simultaneously obtained by the combination of collision-induced desorption (CID) technique and tandem mass spectrometry (MS/MS) of QITMS. The phosphorylated peptide was identified by looking into whether the difference between the observed and predicted molecular weights of a peptide is 80 u or its integral multiple. Then the phosphorylation site was identified through manual interpretation of the MS/MS spectrum of the phosphorylated peptide or automatic SEQUEST data base-searching.

  9. Speciation of Selenium in Selenium-Enriched Sunflower Oil by High-Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry/Electrospray-Orbitrap Tandem Mass Spectrometry.

    Science.gov (United States)

    Bierla, Katarzyna; Flis-Borsuk, Anna; Suchocki, Piotr; Szpunar, Joanna; Lobinski, Ryszard

    2016-06-22

    The reaction of sunflower oil with selenite produces a complex mixture of selenitriglycerides with antioxidant and anticancer properties. To obtain insight into the identity and characteristics of the species formed, an analytical approach based on the combination of high-performance liquid chromatography (HPLC) with (78)Se-specific selenium detection by inductively coupled plasma mass spectrometry (ICP MS) and high-resolution (100 000), high mass accuracy (sunflower oil dissolved in isopropanol and methanol extract of the oil containing 65% selenium. HPLC-ICP MS showed 14 peaks, 11 of which could also be detected in the methanol extract. Isotopic patterns corresponding to molecules with one or two selenium atoms could be attributed by Orbitrap MS at the retention times corresponding to the HPLC-ICP MS peak apexes. Structural data for these species were acquired by MS(2) and MS(3) fragmentation of protonated or sodiated ions using high-energy collisional dissociation (HCD). A total of 11 selenium-containing triglycerol derivatives resulting from the oxidation of one or two double bonds of linoleic acid and analogous derivatives of glycerol-mixed linoleate(s)/oleinate(s) have been identified for the first time. The presence of these species was confirmed by the targeted analysis in the total oil isopropanol solution. Their identification corroborated the predicted elution order in reversed-phase chromatography: LLL (glycerol trilinoleate), LLO (glycerol dilinoleate-oleinate), LOO (glycerol linoleate-dioleinate), OOO (glycerol trioleinate), of which the extrapolation allowed for the prediction of the identity [glycerol dioleinate-stearate (OOS) and glycerol oleinate-distearate (OSS)] of the nonpolar species detected by ICP MS in the oil but not detected by electrospray MS.

  10. [Quantification of acrylamide in foods by gas chromatography-mass spectrometry coupled with pro-column derivatization].

    Science.gov (United States)

    Yang, Sichao; Zhang, Hui; Wang, Junhan; Chen, Fang

    2011-05-01

    The quantification of acrylamide in foods was investigated by gas chromatography-mass spectrometry (GC-MS). In this method, (13)C3-acrylamide was used as an internal standard. The samples were homogenized, defatted with hexane and extracted with ethyl acetate for twice. The derivatization of acrylamide into 2-bromopropenamide (2-BPA) was done using potassium bromide/potassium bromate at 4 degrees C for 90 min. Selective ion monitoring mode was chosen to monitor objective chromatography. This method had a good linearity between 0.05-2.00 mg/kg (r2 = 0.9995), and the limits of detection and quantification were 3 microg/kg and 7 microg/kg, respectively. The recoveries of acrylamide were in the range of 62.7%-65.5%. In order to confirm this GC-MS method, the acrylamide in foods was also determined by high performance liquid chromatography coupled to quadrupole tandem mass spectrometry (HPLC-MS/MS), which had been proved in our laboratory. The concentrations of acrylamide in the samples quantified by GC-MS were slightly higher than those detected by HPLC-MS/MS. This method can be used to quantify acrylamide in normal foods.

  11. Characterization of phosphoantigens by high-performance anion-exchange chromatography-electrospray ionization ion trap mass spectrometry and nanoelectrospray ionization ion trap mass spectrometry.

    Science.gov (United States)

    Pont, F; Luciani, B; Belmant, C; Fournié, J J

    2001-08-01

    New phosphorylated microbial metabolites referred to as phosphoantigens activate immune responses in humans. Although these molecules have leading applications in medical research, no direct method allows their rapid and unambiguous structural identification. Here, we interfaced online HPAEC (high performance anion-exchange chromatography) with ESI-ITMS (electrospray ionization ion trap mass spectrometry) to identify such pyrophosphorylated molecules. A self-regenerating anion suppressor located upstream of electrospray ionization enabled the simultaneous detection of pyrophosphoester by conductimetry, UV and MS. By HPAEC-ITMS and HPAEC-ITMS2, a single run permitted characterization of reference phosphoantigens and of related structures. Although all compounds were resolved by HPAEC, MS enabled their detection and identification by [M-H]- and fragment ions. Isobaric phosphoantigen analogues were also separated by HPAEC and distinguished by MS2. The relevance of this device was demonstrated for phosphoantigens analysis in human urine and plasma. Furthermore, identification of natural phosphoantigens by automatically generated 2D mass spectra from nano-ESI-ITMS is presented. This last technique permits the simultaneous performance of molecular screening of natural phosphoantigen extracts and their identification.

  12. [Comparison of the performances of gas chromatography-quadrupole time of flight mass spectrometry and gas chromatography-tandem mass spectrometry in rapid screening and confirmation of 208 pesticide residues in fruits and vegetables].

    Science.gov (United States)

    Cao, Xinyue; Pang, Guofang; Jin, Linghe; Kang, Jian; Hu, Xueyan; Chang, Qiaoying; Wang, Minglin; Fan, Chunlin

    2015-04-01

    The performances of gas chromatography-tandem mass spectrometry (GC-MS/MS) and gas chromatography quadrupole time of flight mass spectrometry (GC-QTOF/MS) for the determination of 208 pesticide residues in fruit and vegetable samples, including apple, orange, tomato and cucumber, were compared comprehensively. Based on the differences of the two instruments, their respective characteristics and scopes of application in the detection of the pesticide residues were presented, which provided the reference for the analysis of pesticide residues. The performance parameters of the two instruments, such as overall recoveries, precisions, limits of detection, linear ranges, identification points and matrix effects, were evaluated according to a designed experiment. At three spiked levels (5.0, 10.0 and 20.0 µg/kg), the average recoveries for the majority of pesticides (93.0%) ranged from 70% to 120% in the four matrices with relative standard deviations below 20%. The limits of detection for most of the pesticides by GC-MS/MS and GC-Q-TOF/MS were less than 5.0 µg/kg. Compared with GC-QTOF/MS, GC-MS/MS showed relatively lower limits of detection and wider linear ranges, and its performance was more satisfactory in accurate quantitative analysis due to its superior sensitivity. On the other hand, GC-QTOF/MS provided accurate mass measurement, which was proved to be an efficient analytical tool on the rapid screening and confirmation of a large number of pesticides and non-target compounds.

  13. Wide-scope screening and quantification of 50 pesticides in wine by liquid chromatography/quadrupole time-of-flight mass spectrometry combined with liquid chromatography/quadrupole linear ion trap mass spectrometry.

    Science.gov (United States)

    He, Zeying; Xu, Yaping; Wang, Lu; Peng, Yi; Luo, Ming; Cheng, Haiyan; Liu, Xiaowei

    2016-04-01

    In this paper, a wide scope screening method of pesticides in wine was established using liquid chromatography/quadrupole time-of-flight mass spectrometry (LC-QTOF MS) and liquid chromatography/quadrupole linear ion trap mass spectrometry (LC-QqLIT MS). Information dependent acquisition (IDA) experiments are used to obtain both MS and MS/MS information for LC-QTOF MS analysis. For LC-QqLIT MS analysis, MS/MS spectra of target pesticides were simultaneously acquired using Enhanced Product Ion (EPI) mode at very low concentrations to increase the confidence in analytical results of multiple reaction monitoring (MRM) by library searching. Method validation was carried out using 50 pesticides commonly used in vineyards. The LOQs, linearity, repeatability were determined and good enough for quantification. The screening and quantification results obtained using LC-QTOF MS and LC-QqLIT MS were compared. Contaminants were screened against libraries containing over 2800 compounds based on accurate mass, isotopic patterns, and MS/MS spectra searching to extend the scope of this methodology to non-target screening.

  14. Forensic Mass Spectrometry

    Science.gov (United States)

    Hoffmann, William D.; Jackson, Glen P.

    2015-07-01

    Developments in forensic mass spectrometry tend to follow, rather than lead, the developments in other disciplines. Examples of techniques having forensic potential born independently of forensic applications include ambient ionization, imaging mass spectrometry, isotope ratio mass spectrometry, portable mass spectrometers, and hyphenated chromatography-mass spectrometry instruments, to name a few. Forensic science has the potential to benefit enormously from developments that are funded by other means, if only the infrastructure and personnel existed to adopt, validate, and implement the new technologies into casework. Perhaps one unique area in which forensic science is at the cutting edge is in the area of chemometrics and the determination of likelihood ratios for the evaluation of the weight of evidence. Such statistical techniques have been developed most extensively for ignitable-liquid residue analyses and isotope ratio analysis. This review attempts to capture the trends, motivating forces, and likely impact of developing areas of forensic mass spectrometry, with the caveat that none of this research is likely to have any real impact in the forensic community unless: (a) The instruments developed are turned into robust black boxes with red and green lights for positives and negatives, respectively, or (b) there are PhD graduates in the workforce who can help adopt these sophisticated techniques.

  15. A versatile method for stable carbon isotope analysis of carbohydrates by high-performance liquid chromatography/isotope ratio mass spectrometry

    NARCIS (Netherlands)

    Boschker, H.T.S.; Moerdijk-Poortvliet, T.C.W.; Van Breugel, P.; Houtekamer, M.J.; Middelburg, J.J.

    2008-01-01

    We have developed a method to analyze stable carbon isotope (13C/12C) ratios in a variety of carbohydrates using high-performance liquid chromatography/isotope ratio mass spectrometry (HPLC/IRMS). The chromatography is based on strong anion-exchange columns with low strength NaOH eluents. An eluent

  16. Multi-detection of corticosteroids in sports doping and veterinary control using high-resolution liquid chromatography/time-of-flight mass spectrometry

    NARCIS (Netherlands)

    Touber, M.E.; Engelen, M.C.; Georgakopoulus, C.; Rhijn, van J.A.; Nielen, M.W.F.

    2007-01-01

    A liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) method was developed using the latest high-resolution LC column technology, the ultra performance liquid chromatography (UPLC (TM)), and electrospray ionization (ESI) in the positive ion mode. Gradient UPLC separation conditions wer

  17. Multidimensional Separation of Natural Products Using Liquid Chromatography Coupled to Hadamard Transform Ion Mobility Mass Spectrometry

    Science.gov (United States)

    Liu, Wenjie; Zhang, Xing; Knochenmuss, Richard; Siems, William F.; Hill, Herbert H.

    2016-05-01

    A high performance liquid chromatograph (HPLC)was interfaced to an atmospheric drift tube ion mobility time of flight mass spectrometry. The power of multidimensional separation was demonstrated using chili pepper extracts. The ambient pressure drift tube ion mobility provided high resolving powers up to 166 for the HPLC eluent. With implementation of Hadamard transform (HT), the duty cycle for the ion mobility drift tube was increased from less than 1% to 50%, and the ion transmission efficiency was improved by over 200 times compared with pulsed mode, improving signal to noise ratio 10 times. HT ion mobility and TOF mass spectrometry provide an additional dimension of separation for complex samples without increasing the analysis time compared with conventional HPLC.

  18. Quantitative Analysis and Fingerprint Profiles for Quality Control of Fructus Schisandrae by Gas Chromatography: Mass Spectrometry

    OpenAIRE

    Yong-Gang Xia; Bing-You Yang; Jun Liang; Qi Yang; Di Wang; Hai-Xue Kuang

    2014-01-01

    This paper describes a simple, rapid, and effective quality assessment method for Fructus Schisandrae by gas chromatography-mass spectrum (GC-MS). The method was established by using specific lignan fingerprint profiles and quantitation of characteristic compounds in this herbal medicine. The GC-MS fingerprints of 15 batches of Schisandra samples from different regions of China showed similar lignan profiles. Five peaks were selected as characteristic peaks, and all of these were identified b...

  19. Analysis of Phenolic Antioxidants in Navy Mobility Fuels by Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    2013-06-19

    methyl phenol ECD Electrochemical detector GC-MS Gas chromatography with mass selective detection HT Hydrotreated HPLC High Performance...Antioxidants are often used to meet military storage stability requirements and are required in hydrotreated and alternative fuels. It is often necessary to...constituents to be quantifiable by this method. The single column method was successfully employed to measure TTBP depletion in hydrotreated Jet A fuels

  20. Gas Chromatography-Mass Spectrometry Based Isotopic Abundance Ratio Analysis of Biofield Energy Treated Methyl-2-napthylether (Nerolin)

    OpenAIRE

    2016-01-01

    Methyl-2-napthylether (nerolin) is an organic compound and has the applications in pharmaceutical, and perfume industry. The stable isotope ratio analysis is increasing importance in various field of scientific research. The objective of the current study was to evaluate the effect of the biofield energy treatment on the isotopic abundance ratios of PM+1/PM(2H/1H or 13C/12C or 17O/16O) and PM+2/PM (18O/16O) in nerolin using the gas chromatography-mass spectrometry (GC-MS). The compound neroli...

  1. The use of liquid chromatography tandem mass spectrometry to detect proteins in saliva from horses with and without systemic inflammation

    DEFF Research Database (Denmark)

    Jacobsen, Stine; Top Adler, Ditte Marie; Bundgaard, Louise

    2014-01-01

    The objective of the study was to assess global expression of proteins in equine saliva using liquid chromatography tandem mass spectrometry (LC-MS/MS). Saliva was obtained from seven horses with and six horses without evidence of systemic inflammatory disease. Tryptic peptides from saliva were......, and alpha1-acid glycoprotein. The study is the first to describe detection of inflammatory proteins in horse saliva. The proteins detected were similar to those described in saliva from cattle, small ruminants and pigs. Detection of APPs in horses with systemic inflammation suggests that saliva may be used...

  2. Colostrum protein uptake in neonatal lambs examined by descriptive and quantitative liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Hernandez-Castellano, Lorenzo E; Argueello, Anastasio; Almeida, Andre M

    2015-01-01

    Colostrum intake is a key factor for newborn ruminant survival because the placenta does not allow the transfer of immune components. Therefore, newborn ruminants depend entirely on passive immunity transfer from the mother to the neonate, through the suckling of colostrum. Understanding...... dodecyl sulfate-PAGE for protein separation and in-gel digestion, followed by liquid chromatography-tandem mass spectrometry of resulting tryptic peptides for protein identification. An isobaric tag for relative and absolute quantitation (iTRAQ)-based proteomics approach was subsequently used to provide...

  3. Identification of Ceftiofur Oxidation Products by High-Performance Liquid Chromatography/Electrospray Ionization/Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Hye-Sung Cho

    2011-03-01

    Full Text Available Oxidation products of ceftiofur were formed in hydrogen peroxide solution. The structures of the ceftiofur oxidationproducts were characterized by high-performance liquid chromatography/electrospray ionization/tandem mass spectrometry(HPLC/ESI/MS/MS. The products were identified as compounds oxidized at the sulfur of a cephem ring. For further analysis,experiments were performed using O18-labeled hydrogen peroxide. In addition, density-functional calculations were carried out forsix possible oxidation products to support the experimental results.

  4. Separation and characterization of phenolic compounds in fennel (Foeniculum vulgare) using liquid chromatography-negative electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Parejo, Irene; Jauregui, Olga; Sánchez-Rabaneda, Ferran; Viladomat, Francesc; Bastida, Jaume; Codina, Carles

    2004-06-16

    Liquid chromatography (LC) diode array detection (DAD) coupled to negative electrospray ionization (ESI) tandem mass spectrometry (MS/MS) was used for the rapid and sensitive identification of water-soluble phenolic compounds in fennel waste. The plant material was first extracted and then chromatographed on Sephadex LH-20 to afford seven fractions, each of them being subjected to LC-MS analysis. Identification of the compounds was carried out by interpretation of UV, MS, and MS/MS spectra. Forty-two phenolic substances were identified, 27 of which had not previously been reported in fennel, including hydroxycinnamic acid derivatives, flavonoid glycosides, and flavonoid aglycons.

  5. Quality assurance of commercial beeswax. Part I. Gas chromatography-electron impact ionization mass spectrometry of hydrocarbons and monoesters.

    Science.gov (United States)

    Jiménez, J J; Bernal, J L; Aumente, S; del Nozal, Ma J; Martín, Ma T; Bernal, J

    2004-01-23

    The use of low-temperature capillary gas chromatography coupled to electron impact mass spectrometry for the characterization of crude beeswaxes yielded by Apis mellifera is described. The system allows the identification of a great number of compounds, some of them not reported till now in beeswax, such as a family of ethyl esters, tetracosyl oleate, and several saturated and unsaturated hydrocarbons. The information acquired makes possible the differentiation between pure beeswax and some foundation beeswax samples where mixture of pure beeswax with another substances is suspected.

  6. Rapid quantification of the metabolite of valacyclovir hydrochloride in human plasma by liquid chromatography-tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Objective To establish a rapid,sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of acyclovir (the metabolite of valacyclovir hydrochloride) in human plasma. Methods After addition of ganciclovir as internal standard (IS),plasma samples were prepared by one-step protein precipitation using acetonitrile as precipitant,followed by an isocratic elution with 0.1% formic acid solution-methanol (95∶5,v/v) on an Agilent ZORBAX SB-C18 (150mm×2.1mm i.d.,3....

  7. The composition of volatile components in olivines from Yakutian kimberlites of various ages: Evidence from gas chromatography-mass spectrometry

    Science.gov (United States)

    Tomilenko, A. A.; Bul'bak, T. A.; Khomenko, M. O.; Kuzmin, D. V.; Sobolev, N. V.

    2016-06-01

    The composition of volatiles from fluid and melt inclusions in olivine phenocrysts from Yakutian kimberlite pipes of various ages (Olivinovaya, Malokuonapskaya, and Udachnaya-East) were studied for the first time by gas chromatography-mass spectrometry. It was shown that hydrocarbons and their derivatives, as well as nitrogen-, halogen-, and sulfur-bearing compounds, played a significant role in the mineral formation. The proportion of hydrocarbons and their derivatives in the composition of mantle fluids could reach 99%, including up to 4.9% of chlorineand fluorine-bearing compounds.

  8. Large-scale analysis of in Vivo phosphorylated membrane proteins by immobilized metal ion affinity chromatography and mass spectrometry

    DEFF Research Database (Denmark)

    Nühse, Thomas S; Stensballe, Allan; Jensen, Ole N

    2003-01-01

    plasma membrane digests and detected and sequenced by mass spectrometry. We present a scheme for two-dimensional peptide separation using strong anion exchange chromatography prior to IMAC that both decreases the complexity of IMAC-purified phosphopeptides and yields a far greater coverage...... of monophosphorylated peptides. Among the identified sequences, six originated from different isoforms of the plasma membrane H(+)-ATPase and defined two previously unknown phosphorylation sites at the regulatory C terminus. The potential for large-scale identification of phosphorylation sites on plasma membrane...

  9. Screening and determination of drugs in human saliva utilizing microextraction by packed sorbent and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Abdel-Rehim, Abbi; Abdel-Rehim, Mohamed

    2013-09-01

    This study presents a new method for collecting and handling saliva samples using an automated analytical microsyringe and microextraction by packed syringe (MEPS). The screening and determination of lidocaine in human saliva samples utilizing MEPS and liquid chromatography-tandem mass spectrometry (LC-MS/MS) were carried out. An exact volume of saliva could be collected. The MEPS C8 -cartridge could be used for 50 extractions before it was discarded. The extraction recovery was about 60%. The pharmacokinetic curve of lidocaine in saliva using MEPS-LC-MS/MS is reported.

  10. [Progress in quantitative methods based on liquid chromatography-mass spectrometry for drug metabolizing enzymes in human liver microsomes].

    Science.gov (United States)

    Wang, Huanhuan; Lu, Yayao; Peng, Bo; Qian, Xiaohong; Zhang, Yangjun

    2015-06-01

    Cytochrome P450 (CYP) enzymes and uridine 5-diphospho-glucuronosyltransferase (UGT) enzymes are critical enzymes for drug metabolism. Both chemical drugs and traditional Chinese medicines are converted to more readily excreted compounds by drug metabolizing enzymes in human livers. Because of the disparate expression of CYP and UGT enzymes among different individuals, accurate quantification of these enzymes is essential for drug pharmacology, drug-drug interactions and drug clinical applications. The research progress in quantitative methods based on liquid chromatography-mass spectrometry for drug metabolizing enzymes in human liver microsomes in the recent decade is reviewed.

  11. Application of acetate derivatives for gas chromatography-mass spectrometry: novel approaches on carbohydrates, lipids and amino acids analysis.

    Science.gov (United States)

    Sassaki, Guilherme L; Souza, Lauro M; Serrato, Rodrigo V; Cipriani, Thales R; Gorin, Philip A J; Iacomini, Marcello

    2008-10-24

    The structure of glycoconjugates has been determined by several chromatographic methods, however gas chromatography-mass spectrometry (GC-MS) has been widely used to identify and quantify the volatile trimethylsilyl and fluoroacyl derivatives. Adapting the reduction/acetylation strategies, we had performed the derivatization of all monosaccharide class, as well as amino acids and OH-fatty acids as from different glycoconjugates. Uronic acids gave characteristic ions at m/z 143, 156 and 173, and 19 amino acids derivatives, gave molecular ions [M]+ and daughter ions of [M-59]+ and [M-43]+ on electron impact (EI)-MS, which provide their rapid identification.

  12. Use of an intravenous microdose of 14C-labeled drug and accelerator mass spectrometry to measure absolute oral bioavailability in dogs; cross-comparison of assay methods by accelerator mass spectrometry and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Miyaji, Yoshihiro; Ishizuka, Tomoko; Kawai, Kenji; Hamabe, Yoshimi; Miyaoka, Teiji; Oh-hara, Toshinari; Ikeda, Toshihiko; Kurihara, Atsushi

    2009-01-01

    A technique utilizing simultaneous intravenous microdosing of (14)C-labeled drug with oral dosing of non-labeled drug for measurement of absolute bioavailability was evaluated using R-142086 in male dogs. Plasma concentrations of R-142086 were measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and those of (14)C-R-142086 were measured by accelerator mass spectrometry (AMS). The absence of metabolites in the plasma and urine was confirmed by a single radioactive peak of the parent compound in the chromatogram after intravenous microdosing of (14)C-R-142086 (1.5 microg/kg). Although plasma concentrations of R-142086 determined by LC-MS/MS were approximately 20% higher than those of (14)C-R-142086 as determined by AMS, there was excellent correlation (r=0.994) between both concentrations after intravenous dosing of (14)C-R-142086 (0.3 mg/kg). The oral bioavailability of R-142086 at 1 mg/kg obtained by simultaneous intravenous microdosing of (14)C-R-142086 was 16.1%, this being slightly higher than the value (12.5%) obtained by separate intravenous dosing of R-142086 (0.3 mg/kg). In conclusion, on utilizing simultaneous intravenous microdosing of (14)C-labeled drug in conjunction with AMS analysis, absolute bioavailability could be approximately measured in dogs, but without total accuracy. Bioavailability in humans may possibly be approximately measured at an earlier stage and at a lower cost.

  13. New Potential Biomarker for Methasterone Misuse in Human Urine by Liquid Chromatography Quadrupole Time of Flight Mass Spectrometry

    Science.gov (United States)

    Zhang, Jianli; Lu, Jianghai; Wu, Yun; Wang, Xiaobing; Xu, Youxuan; Zhang, Yinong; Wang, Yan

    2016-01-01

    In this study, methasterone urinary metabolic profiles were investigated by liquid chromatography quadrupole time of flight mass spectrometry (LC-QTOF-MS) in full scan and targeted MS/MS modes with accurate mass measurement. A healthy male volunteer was asked to take the drug and liquid–liquid extraction was employed to process urine samples. Chromatographic peaks for potential metabolites were hunted out with the theoretical [M − H]− as a target ion in a full scan experiment and actual deprotonated ions were studied in targeted MS/MS experiment. Fifteen metabolites including two new sulfates (S1 and S2), three glucuronide conjugates (G2, G6 and G7), and three free metabolites (M2, M4 and M6) were detected for methasterone. Three metabolites involving G4, G5 and M5 were obtained for the first time in human urine samples. Owing to the absence of helpful fragments to elucidate the steroid ring structure of methasterone phase II metabolites, gas chromatography mass spectrometry (GC-MS) was employed to obtain structural information of the trimethylsilylated phase I metabolite released after enzymatic hydrolysis and the potential structure was inferred using a combined MS method. Metabolite detection times were also analyzed and G2 (18-nor-17β-hydroxymethyl-2α, 17α-dimethyl-androst-13-en-3α-ol-ξ-O-glucuronide) was thought to be new potential biomarker for methasterone misuse which can be detected up to 10 days. PMID:27669235

  14. Chemical profiling and quantification of Gua-Lou-Gui-Zhi decoction by high performance liquid chromatography/quadrupole-time-of-flight mass spectrometry and ultra-performance liquid chromatography/triple quadrupole mass spectrometry.

    Science.gov (United States)

    Xu, Wen; Huang, Mingqing; Li, Huang; Chen, Xianwen; Zhang, Yuqin; Liu, Jie; Xu, Wei; Chu, Kedan; Chen, Lidian

    2015-04-01

    Gua-Lou-Gui-Zhi decoction (GLGZD) is a classical formula of traditional Chinese medicine, which has been commonly used to treat dysfunction after stroke, epilepsy and spinal cord injury. In this study, a systematic method was established for chemical profiling and quantification analysis of the major constituents in GLGZD. For qualitative analysis, a method of high performance liquid chromatography/quadrupole time-of-flight mass spectrometry (Q-TOF MS) was developed. 106 compounds, including monoterpene glycosides, galloyl glucoses, phenolic acids, flavonoids, gingerols and triterpene saponins were identified or tentatively presumed by comparison with reference standards or literature data. According to the qualitative results, a new quantitative analysis method of ultra-performance liquid chromatography/triple quadrupole mass spectrometry (QqQ-MS) was established. 24 representative compounds were simultaneously detected in 10 batches of GLGZD samples in 7.5 min. The calibration curves for all analytes showed good linearity (r>0.9959) within the test ranges. The LODs and the LOQs were less than 30.6 and 70.9 ng/mL, respectively. The RSDs of intra- and inter-day precision, repeatability and stability were below 3.64%, 4.85%, 4.84% and 3.87%, respectively. The overall recoveries ranged from 94.94% to 103.66%, with the RSDs within 5.12%. This study established a high sensitive and efficient method for the integrating quality control, including identification and quantification of Chinese medicinal preparation.

  15. Coal liquefaction process streams characterization and evaluation. Characterization of coal-derived materials by field desorption mass spectrometry, two-dimensional nuclear magnetic resonance, supercritical fluid extraction, and supercritical fluid chromatography/mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, J.A.; Linehan, J.C.; Robins, W.H. [Battelle Pacific Northwest Lab., Richland, WA (United States)

    1992-07-01

    Under contract from the DOE , and in association with CONSOL Inc., Battelle, Pacific Northwest Laboratory (PNL) evaluated four principal and several complementary techniques for the analysis of non-distillable direct coal liquefaction materials in support of process development. Field desorption mass spectrometry (FDMS) and nuclear magnetic resonance (NMR) spectroscopic methods were examined for potential usefulness as techniques to elucidate the chemical structure of residual (nondistillable) direct coal liquefaction derived materials. Supercritical fluid extraction (SFE) and supercritical fluid chromatography/mass spectrometry (SFC/MS) were evaluated for effectiveness in compound-class separation and identification of residual materials. Liquid chromatography (including microcolumn) separation techniques, gas chromatography/mass spectrometry (GC/MS), mass spectrometry/mass spectrometry (MS/MS), and GC/Fourier transform infrared (FTIR) spectroscopy methods were applied to supercritical fluid extracts. The full report authored by the PNL researchers is presented here. The following assessment briefly highlights the major findings of the project, and evaluates the potential of the methods for application to coal liquefaction materials. These results will be incorporated by CONSOL into a general overview of the application of novel analytical techniques to coal-derived materials at the conclusion of CONSOL`s contract.

  16. Gas and liquid chromatography with inductively coupled plasma mass spectrometry detection for environmental speciation analysis — advances and limitations

    Science.gov (United States)

    Szpunar, Joanna; McSheehy, Shona; Połeć, Kasia; Vacchina, Véronique; Mounicou, Sandra; Rodriguez, Isaac; Łobiński, Ryszard

    2000-07-01

    Recent advances in the coupling of gas chromatography (GC) and high performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICP MS) and their role in trace element speciation analysis of environmental materials are presented. The discussion is illustrated with three research examples concerning the following topics: (i) development and coupling of multicapillary microcolumn GC with ICP MS for speciation of organotin in sediment and biological tissue samples; (ii) speciation of arsenic in marine algae by size-exclusion-anion-exchange HPLC-ICP MS; and (iii) speciation of cadmium in plant cell cultures by size-exclusion HPLC-ICP MS. Particular attention is paid to the problem of signal identification in ICP MS chromatograms; the potential of electrospray MS/MS for this purpose is highlighted.

  17. Screening method for benzodiazepines and hypnotics in hair at pg/mg level by liquid chromatography-mass spectrometry/mass spectrometry.

    Science.gov (United States)

    Villain, Marion; Concheiro, Marta; Cirimele, Vincent; Kintz, Pascal

    2005-10-15

    A procedure is presented for the screening of 16 benzodiazepines and hypnotics in human hair by LC-MS/MS (alprazolam, 7-aminoclonazepam, 7-aminoflunitrazepam, bromazepam, clobazam, diazepam, lorazepam, lormetazepam, midazolam, nordiazepam, oxazepam, temazepam, tetrazepam, triazolam, zaleplon and zolpidem). The method involves decontamination of hair with methylene chloride, hair cut into small pieces, incubation of 20 mg in phosphate buffer (pH 8.4) in the presence of 1 ng diazepam-d5 used as internal standard, liquid-liquid extraction with diethyl ether/methylene chloride (10/90) and separation using liquid chromatography-tandem mass spectrometry. The limits of quantification for all benzodiazepines and hypnotics range from 0.5 to 5 pg/mg using a 20-mg hair sample. Linearity is observed from the limit of quantification of each compound to 200 pg/mg (r2 > 0.99). Coefficients of variation measured on six points and at two concentrations (10 and 50 pg/mg) range from 5 to 20% for all drugs but one. Extraction recovery, measured at the two same concentrations range from 32 to 76%. These results were found suitable to screen for 16 benzodiazepines in hair and detect them at very low concentrations, making this method suitable to monitor single dose.

  18. Ring positional differentiation of isomeric N-alkylated fluorocathinones by gas chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Westphal, Folker; Junge, Thomas

    2012-11-30

    In analogy to our previously published procedure for the differentiation of regioisomeric fluoroamphetamines a method was developed, to differentiate ring positional isomeric fluorocathinones by product ion spectrometry of ions generated by chemical ionization (CI) under GC-MS conditions using methane as reagent gas. N-alkylated ortho-, meta- and para-fluorocathinones could be unequivocally differentiated by product ion spectrometry of the hydrogen fluoride loss ions [M+H-HF](+) using a triple quadrupole mass spectrometer with argon as collision gas under normalized collision conditions. This method enables the differentiation of ring positional isomers of fluorocathinones even in complex mixtures and low concentrations. The applicability of the method was shown by the analysis of synthesized N-alkylated ortho-, meta- and para-fluorocathinones and seized designer drug mixtures.

  19. Determination of methyl tert-butyl ether (MTBE) in Chinese fuels by gas chromatography/mass spectrometry and gas chromatography/flame ionization detector

    Institute of Scientific and Technical Information of China (English)

    LIU Jie-min; CHENG Wei; WEN Mei-juan; JIANG Gui-bin

    2004-01-01

    A method was developed to determine the concentration of methyl tert-butyl ether(MTBE) in gasoline,diesel and heating oil by gas chromatography(GC) with mass spectrometry(GC-MS) or flame ionization detection (FID). The diluted gasoline was directly injected into the GC, and the complete separation of MTBE from co-eluting hydrocarbons was not required. GC/MS or GC/FID method can be used to analyze MTBE in different concentration range and have good consistency.

  20. Characterization of polysorbate 85, a nonionic surfactant, by liquid chromatography vs. ion mobility separation coupled with tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Solak Erdem, Nilüfer; Alawani, Nadrah; Wesdemiotis, Chrys, E-mail: wesdemiotis@uakron.edu

    2014-01-15

    Graphical abstract: -- Highlights: •Liquid chromatography (LC) separates amphiphilic blends according to hydrophobicity. •Ion mobility (IM) spectrometry separates these blends based on molecular size/shape. •LC–MS provides the separation resolution needed for quantifying fatty acid content. •IM–MS enables rapid, solvent-free separation and the detection of trace components. •With either method, tandem MS allows to count the hydrophobic substituents. -- Abstract: Liquid chromatography (LC) and ion mobility (IM) separation have been coupled with mass spectrometry (MS) and tandem mass spectrometry (MS{sup 2}) to characterize a commercially important nonionic surfactant, polysorbate 85. The constituents of this amphiphilic blend contained a sorbitan or isosorbide core that was chain extended with poly(ethylene oxide) (PEO) and partially esterified at the PEO termini with oleic acid or, to a lesser extent, other fatty acids. Using interactive LC in reverse-phase mode, the oligomers of the surfactant were separated according to their hydrophobicity/hydrophilicity balance. On the other hand, IM spectrometry dispersed the surfactant oligomers by their charge and collision cross section (i.e. size/shape). With either separation method, an increased number of fatty ester groups and/or lack of the polar sorbitan (or isosorbide) core led to higher retention/drift times, enabling the separation of isobaric species or species with superimposed isotope patterns, so that their ester content could be conclusively identified by MS{sup 2}. LC–MS and IM–MS permitted the detection of several byproducts besides the major PEO-sorbitan oleate oligomers. LC–MS provides the separation resolution needed for quantitative determination of the degree of esterification. IM–MS, which minimizes analysis time and solvent use, is ideally suitable for a fast, qualitative survey of samples differing in their minor constituents or impurities.

  1. Multiclass mycotoxin analysis in food, environmental and biological matrices with chromatography/mass spectrometry.

    Science.gov (United States)

    Capriotti, Anna Laura; Caruso, Giuseppe; Cavaliere, Chiara; Foglia, Patrizia; Samperi, Roberto; Laganà, Aldo

    2012-01-01

    Mold metabolites that can elicit deleterious effects on other organisms are classified as mycotoxins. Human exposure to mycotoxins occurs mostly through the intake of contaminated agricultural products or residues due to carry over or metabolite products in foods of animal origin such as milk and eggs, but can also occur by dermal contact and inhalation. Mycotoxins contained in moldy foods, but also in damp interiors, can cause diseases in humans and animals. Nephropathy, various types of cancer, alimentary toxic aleukia, hepatic diseases, various hemorrhagic syndromes, and immune and neurological disorders are the most common diseases that can be related to mycotoxicosis. The absence or presence of mold infestation and its propagation are seldom correlated with mycotoxin presence. Mycotoxins must be determined directly, and suitable analytical methods are necessary. Hundreds of mycotoxins have been recognized, but only for a few of them, and in a restricted number of utilities, a maximum acceptable level has been regulated by law. However, mycotoxins seldom develop alone; more often various types and/or classes form in the same substrate. The co-occurrence might render the individual mycotoxin tolerance dose irrelevant, and therefore the mere presence of multiple mycotoxins should be considered a risk factor. The advantage of chromatography/mass spectrometry (MS) is that many compounds can be determined and confirmed in one analysis. This review illustrates the state-of-the-art of mycotoxin MS-based analytical methods for multiclass, multianalyte determination in all the matrices in which they appear. A chapter is devoted to the history of the long-standing coexistence and interaction among humans, domestic animals and mycotoxicosis, and the history of the discovery of mycotoxins. Quality assurance, although this topic relates to analytical chemistry in general, has been also examined for mycotoxin analysis as a preliminary to the systematic literature excursus

  2. Study of Saiga Horn Using High-Performance Liquid Chromatography with Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Kateřina Mikulíková

    2012-01-01

    Full Text Available The saiga horns have been investigated the using of modern analytic methods. High-performance liquid chromatography (HPLC with mass-spectrometric (MS and MS/MS detection and polyacrylamide gel electrophoresis (PAGE were used. It could be concluded that basic proteins of the saiga horns are keratins and collagen. The basic representation protein in all samples is keratin type I microfibrillar (from sheep, keratin type II microfibrillar (from sheep, collagen type I (α1 (from bovine and collagen type I (α2 (from bovine. Free amino acids we determined in all samples are nontreated by enzyme.

  3. Identification of di(ethylhexyl) phthalate as impurity in the analysis by using chromatography gas tandem mass spectrometry

    Science.gov (United States)

    Pusfitasari, Eka Dian; Hendarsyah, Hendris; Salahuddin, Ariani, Novita

    2017-01-01

    Di(ethylhexyl) phthalate (DEHP) is a plasticizer commonly used in plastics. Physically DEHP has a low vapor pressure. DEHP can seep into the liquid in direct contact with the plastic wrapping materials, and typically can occur rapidly if extractable into food or non-polar solvents, such as oil, once the food is packaged in PVC packaging materials. DEHP has been analyzed by using gas chromatography which has a high sensitivity level. If the equipment used for the analysis is made from plastic containing DEHP, then it may be possible that DEHP can be extracted and appear on the outcome of the injection. It can interfere with the process of analysis, especially for the analysis of food samples. This study has identified the present of DEHP in the blank injection performed by Gas Chromatography tandem Mass Spectrometry with Selected Ion Monitoring mode (SIM). Researchers are required to verify whether the gas chromatographic system used is ready for the analysis process. In addition, the comparison and calculation of the intensity of the ion fragmentation spectra generated by mass spectrometry detector can be used for the qualitative determination to ensure the presence of the target compound. In this study is also discussed the differences between the high-intensity fragmentation of DEHP and dioctyl phthalate (DOP).

  4. [Simultaneous determination of 16 organic acids in feed additives by on-line enrichment and ion chromatography-mass spectrometry].

    Science.gov (United States)

    Xiong, Zhiyu; Dong, Ying; Zhou, Hongbin; Yu, Yang; Li, Jing; Sun, Li

    2014-02-01

    A novel analytical method for simultaneous determination of sixteen organic acids by on-line enrichment and ion chromatography-mass spectrometry (IC-MS) was developed. Online enrichment and separation of the organic acids were performed by ion chromatography on a homemade enrichment column and a homemade separation column. The qualitative and quantitative analyses of the organic acids were performed by mass spectrometry in selected ion monitoring (SIM) mode on the basis of atmospheric pressure chemical ionization (APCI) source in negative mode. The sample of 200 microL was injected for the analysis, and the on-line enrichment time was 3 min. The sodium hydroxide solution was used as a gradient elution system. The two columns made it possible to have a low limit of detection due to the good enrichment and separation capability. The sixteen organic acids were separated completely within 30 min. All curves showed good linearity within the test concentration ranges. The limits of detection (LODs) were between 0.01 and 0.22 mg/L, and the average recoveries were between 70.6% and 110.8%. The relative standard deviations (RSDs) were less than 6.3%. The results indicate that this method is simple, rapid, sensitive and accurate for the determination of the organic acids in feed additives.

  5. Simultaneous quantification of amphetamine, opiates, ketamine and relative metabolites in urine for confirmatory analysis by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Lin, Huei-Ru; Choi, Ka-Ian; Lin, Tzu-Chieh; Hu, Anren

    2013-06-15

    The rise in amphetamine, ketamine and opiates abuse in Taiwan has created a need for a reliable confirmatory assay. A method that combines superficially porous liquid chromatography tandem mass spectrometry (LC-MS/MS) with solid-phase extraction (SPE) was developed for the simultaneous quantification of amphetamine, 3,4-methylenedioxymethamphetamine (MDMA), ketamine, opiates, and their corresponding metabolites in urine. The total run time of the method was 6.7min including equilibration time. The method was validated in accordance with the European Commission (EC) Decision 2002/642/EC. The within- and between-day precision was below 13.6% and the accuracy ranged from -17.1% to +9.9% for all analytes. Ion suppression was observed but compensated by using deuterated internal standards. No carryover was detected and the analytes were stable at room temperature for 16h, and for 72h at 4°C, and three-thaw cycles. The method was further validated by comparison with a reference gas chromatography-mass spectrometry (GC-MS) method, using 52 authentic urine samples. The results indicated that for the target analytes studied, the LC-MS/MS analysis was as precise, accurate, and specific as the GC-MS method. In conclusion, the present LC-MS/MS method is robust and reliable, and suitable for use as a confirmation assay in the simultaneous urine drug testing and quantification of amphetamines, ketamines, and opiates.

  6. Determination of short chain carboxylic acids in vegetable oils and fats using ion exclusion chromatography electrospray ionization mass spectrometry.

    Science.gov (United States)

    Viidanoja, Jyrki

    2015-02-27

    A new method for quantification of short chain C1-C6 carboxylic acids in vegetable oils and fats by employing Liquid Chromatography Mass Spectrometry (LC-MS) has been developed. The method requires minor sample preparation and applies non-conventional Electrospray Ionization (ESI) liquid phase chemistry. Samples are first dissolved in chloroform and then extracted using water that has been spiked with stable isotope labeled internal standards that are used for signal normalization and absolute quantification of selected acids. The analytes are separated using Ion Exclusion Chromatography (IEC) and detected with Electrospray Ionization Mass Spectrometry (ESI-MS) as deprotonated molecules. Prior to ionization the eluent that contains hydrochloric acid is modified post-column to ensure good ionization efficiency of the analytes. The averaged within run precision and between run precision were generally lower than 8%. The accuracy was between 85 and 115% for most of the analytes. The Lower Limit of Quantification (LLOQ) ranged from 0.006 to 7mg/kg. It is shown that this method offers good selectivity in cases where UV detection fails to produce reliable results.

  7. Highly sensitive and selective analysis of widely targeted metabolomics using gas chromatography/triple-quadrupole mass spectrometry.

    Science.gov (United States)

    Tsugawa, Hiroshi; Tsujimoto, Yuki; Sugitate, Kuniyo; Sakui, Norihiro; Nishiumi, Shin; Bamba, Takeshi; Fukusaki, Eiichiro

    2014-01-01

    In metabolomics studies, gas chromatography coupled with time-of-flight or quadrupole mass spectrometry has frequently been used for the non-targeted analysis of hydrophilic metabolites. However, because the analytical platform employs the deconvolution method to extract single-metabolite information from co-eluted peaks and background noise, the extracted peak is artificial product depending on the mathematical parameters and is not completely compatible with the pure component obtained by analyzing a standard compound. Moreover, it has insufficient ability for quantitative metabolomics. Therefore, highly sensitive and selective methods capable of pure peak extraction without any complicated mathematical techniques are needed. For this purpose, we have developed a novel analytical method using gas chromatography coupled with triple-quadrupole mass spectrometry (GC-QqQ/MS). We developed a selected reaction monitoring (SRM) method to analyze the trimethylsilyl derivatives of 110 metabolites, using electron ionization. This methodology enables us to utilize two complementary techniques-non-targeted and widely targeted metabolomics in the same sample preparation protocol, which would facilitate the formulation or verification of novel hypotheses in biological sciences. The GC-QqQ/MS analysis can accurately identify a metabolite using multichannel SRM transitions and intensity ratios in the analysis of living organisms. In addition, our methodology offers a wide dynamic range, high sensitivity, and highly reproducible metabolite profiles, which will contribute to the biomarker discoveries and quality evaluations in biology, medicine, and food sciences.

  8. Determination of vanillin, ethyl vanillin, and coumarin in infant formula by liquid chromatography-quadrupole linear ion trap mass spectrometry.

    Science.gov (United States)

    Shen, Yan; Han, Chao; Liu, Bin; Lin, Zhengfeng; Zhou, Xiujin; Wang, Chengjun; Zhu, Zhenou

    2014-02-01

    A simple, precise, accurate, and validated liquid chromatography-quadrupole linear ion trap mass spectrometry method was developed for the determination of vanillin, ethyl vanillin, and coumarin in infant formula samples. Following ultrasonic extraction with methanol/water (1:1, vol/vol), and clean-up on an HLB solid-phase extraction cartridge (Waters Corp., Milford, MA), samples were separated on a Waters XSelect HSS T3 column (150 × 2.1-mm i.d., 5-μm film thickness; Waters Corp.), with 0.1% formic acid solution-acetonitrile as mobile phase at a flow rate of 0.25 mL/min. Quantification of the target was performed by the internal standard approach, using isotopically labeled compounds for each chemical group, to correct matrix effects. Data acquisition was carried out in multiple reaction monitoring transitions mode, monitoring 2 multiple reaction monitoring transitions to ensure an accurate identification of target compounds in the samples. Additional identification and confirmation of target compounds were performed using the enhanced product ion modus of the linear ion trap. The novel liquid chromatography-quadrupole linear ion trap mass spectrometry platform offers the best sensitivity and specificity for characterization and quantitative determination of vanillin, ethyl vanillin, and coumarin in infant formula and fulfills the quality criteria for routine laboratory application.

  9. High Performance Liquid Chromatography Tandem Mass Spectrometry Measurement of Bimatoprost, Latanoprost and Travoprost in Eyelash Enhancing Cosmetic Serums

    Directory of Open Access Journals (Sweden)

    Emilia Marchei

    2016-02-01

    Full Text Available Most common prostaglandin analogs, bimatoprost, latanoprost and travoprost, are licensed for the reduction of elevated intraocular pressure in patients with open angle glaucoma and ocular hypertension, but their non approved use as eyelash enhancers is becoming popular, especially in patients with eyelashes hypotrichosis. A fast and sensitive high performance liquid chromatography tandem mass spectrometry method was developed for the measurement of bimatoprost, latanoprost and travoprost in cosmetic serums freely web-sold to increase eyelash length, thickness and darkness. The analytes and the internal standard (reserpine were separated by reversed phase chromatography with 5 mM ammonium acetate with 0.02% formic acid (mobile phase A and 5 mM ammonium acetate in acetonitrile/water (95/5; v/v with 0.02% formic acid (mobile phase B by gradient elution and detected with tandem mass spectrometry operated in multiple reaction monitoring mode. Linearity between 1 and 500 μg/g shows good correlation coefficients (r2 = 0.99 for all substances. Analytical recovery of analytes under investigation were always higher than 90% and intra-assay and inter-assay precision and accuracy always better than 11%. This method was successfully applied to analyze cosmetic serums freely sold on the Internet websites.

  10. An Ultra-Trace Analysis Technique for SF6 Using Gas Chromatography with Negative Ion Chemical Ionization Mass Spectrometry.

    Science.gov (United States)

    Jong, Edmund C; Macek, Paul V; Perera, Inoka E; Luxbacher, Kray D; McNair, Harold M

    2015-07-01

    Sulfur hexafluoride (SF6) is widely used as a tracer gas because of its detectability at low concentrations. This attribute of SF6 allows the quantification of both small-scale flows, such as leakage, and large-scale flows, such as atmospheric currents. SF6's high detection sensitivity also facilitates greater usage efficiency and lower operating cost for tracer deployments by reducing quantity requirements. The detectability of SF6 is produced by its high molecular electronegativity. This property provides a high potential for negative ion formation through electron capture thus naturally translating to selective detection using negative ion chemical ionization mass spectrometry (NCI-MS). This paper investigates the potential of using gas chromatography (GC) with NCI-MS for the detection of SF6. The experimental parameters for an ultra-trace SF6 detection method utilizing minimal customizations of the analytical instrument are detailed. A method for the detection of parts per trillion (ppt) level concentrations of SF6 for the purpose of underground ventilation tracer gas analysis was successfully developed in this study. The method utilized a Shimadzu gas chromatography with negative ion chemical ionization mass spectrometry system equipped with an Agilent J&W HP-porous layer open tubular column coated with an alumina oxide (Al2O3) S column. The method detection limit (MDL) analysis as defined by the Environmental Protection Agency of the tracer data showed the method MDL to be 5.2 ppt.

  11. Application of integrated comprehensive/multidimensional gas chromatography with mass spectrometry and olfactometry for aroma analysis in wine and coffee.

    Science.gov (United States)

    Chin, Sung-Tong; Eyres, Graham T; Marriott, Philip J

    2015-10-15

    Component coelution in chromatographic analysis complicates identification and attribution of individual odour-active volatile molecules in complex multi-component samples. An integrated system incorporating comprehensive two-dimensional gas chromatography (GC × GC) and multidimensional gas chromatography (MDGC), with flame ionisation, olfactometry and mass spectrometry detection was developed to circumvent data correlation across different systems. Identification of potent odorants in Shiraz wine and the headspace of ground coffee are demonstrated as selected applications. Multiple solid-phase microextraction (SPME) sampling with GC-O located odour-active regions; GC × GC established the complexity of odour-active regions; MDGC provided high-resolution separation for each region; simultaneous 'O' and MS detection completed the analysis for target resolved peaks. Seven odour regions in Shiraz were analysed with MDGC-O/MS detection, revealing 11 odour volatiles through matching of mass spectrometry and retention indices from both separating dimensions, including acetic acid; octen-3-ol; ethyl octanoate; methyl-2-oxo-nonanoate; butanoic acid, 2-methylbutanoic acid, and 3-methylbutanoic acid; 3-(methylthio)-1-propanol; hexanoic acid; β-damascenone; and ethyl-3-phenylpropanoate. A capsicum odour in ground coffee was identified as 2-methoxy-3-isobutylpyrazine with a 5-fold increase in S/N of the odorant when acquired using a 6-time cumulative SPME sampling approach.

  12. Determination of aromatic amines in aqueous extracts of polyurethane foam using hydrophilic interaction liquid chromatography and mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Riddar Johnson, Jakob, E-mail: jakob.riddarjohnson@anchem.su.se [Work Environment Chemistry, Stockholm University, P.O. Box 460, 281 24 Haessleholm (Sweden); Karlsson, Daniel; Dalene, Marianne; Skarping, Gunnar [Work Environment Chemistry, Stockholm University, P.O. Box 460, 281 24 Haessleholm (Sweden)

    2010-09-23

    A method is presented for the determination of aromatic amines in aqueous extracts of polyurethane (PUR) foam. The method is based on the extraction of PUR foam using aqueous acetic acid (0.1%, w/v) followed by determination of extracted aromatic amines using hydrophilic interaction liquid chromatography (HILIC) and tandem mass spectrometry (MS/MS) with positive electrospray ionisation. The injections of volumes up to 5 {mu}L of aqueous solutions were made possible by on-column focusing with partially filled loop injections. The fragmentation patterns for 2,4- and 2,6-toluene diamine (TDA) and 4,4'-methylene dianiline (MDA) were clarified by performing a hydrogen-deuterium exchange study. TDA and MDA were determined using trideuterated 2,4- and 2,6-TDA and dideuterated 4,4'-MDA as internal standards. Linear calibration graphs were obtained over the range 0.025-0.5 {mu}g mL{sup -1} with correlation coefficients >0.996 and the instrumental detection limit for each compound was <50 fmol. The stability of the amines was influenced by the matrix, so their concentrations decreased over time. Agreement was observed between the results of analyses of PUR foam extracts by HILIC-MS/MS and results obtained by ethyl chloroformate derivatisation and reversed phase (RP) liquid chromatography-mass spectrometry (LC-MS/MS). TDA was observed to be unstable in extracts of foam but not in pure solutions.

  13. Analysis of capsaicin and dihydrocapsaicin in peppers and pepper sauces by solid phase microextraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Peña-Alvarez, Araceli; Ramírez-Maya, Erika; Alvarado-Suárez, Luís Angel

    2009-04-01

    A simple method for the analysis of capsaicin and dihydrocapsaicin in peppers and pepper sauces by solid phase microextraction-gas chromatography-mass spectrometry has been developed. A novel device was designed for direct extraction solid phase microextraction in order to avoid damage to the fiber. The analysis was performed without derivatization for the gas chromatography-mass spectrometry analysis. Selection fiber, extraction temperature, extraction time and pH, were optimized. The method was linear in the range 0.109-1.323 microg/mL for capsaicin and 0.107-1.713 microg/mL for dihydrocapsaicin with correlation coefficient up to r=0.9970 for both capsaicinoids. The precision of the method was less than 10%. The method was applied to the analysis of 11 varieties of peppers and four pepper sauces. A broad range of capsaicin (55.0-25 459 microg/g) and dihydrocapsaicin (93-1 130 microg/g) was found in the pepper and pepper sauces samples (4.3-717.3 and 1.0-134.8 microg/g), respectively.

  14. New potential biomarkers for mesterolone misuse in human urine by liquid chromatography quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Lu, Jianghai; Fernández-Álvarez, María; Yang, Sheng; He, Genye; Xu, Youxuan; Aguilera, Rodigo

    2015-01-01

    In this paper, mesterolone metabolic profiles were investigated carefully. Mesterolone was administered to one healthy male volunteer. Urinary extracts were analyzed by liquid chromatography quadruple time-of-flight mass spectrometry (LC-QTOFMS) for the first time. Liquid-liquid extraction was applied to processing urine samples, and dilute-shoot analyses of intact metabolites were also presented. In LC-QTOFMS analysis, chromatographic peaks for potential metabolites were hunt down by using the theoretical [M-H](-) as target ions in full scan experiment, and their actual deprotonated ions were analyzed in targeted MS/MS mode. Ten metabolites including seven new sulfate and three glucuronide conjugates were found for mesterolone. Because of no useful fragment ion for structural elucidation, gas chromatography-mass spectrometry instrumentation was employed to obtain structural details of the trimethylsilylated phase I metabolite released after solvolysis. Thus, their potential structures were proposed particularly by a combined MS approach. All the metabolites were also evaluated in terms of how long they could be detected, and S1 (1α-methyl-5α-androst-3-one-17β-sulfate) together with S2 (1α-methyl-5α-androst-17-one-3β-sulfate) was detected up to 9 days after oral administration, which could be the new potential biomarkers for mesterolone misuse.

  15. Determination of muscimol and ibotenic acid in Amanita mushrooms by high-performance liquid chromatography and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tsujikawa, Kenji; Kuwayama, Kenji; Miyaguchi, Hajime; Kanamori, Tatsuyuki; Iwata, Yuko; Inoue, Hiroyuki; Yoshida, Takemi; Kishi, Tohru

    2007-06-01

    A reliable analytical method was developed for the quantification and identification of muscimol (MUS) and ibotenic acid (IBO), the toxic constituents of Amanita muscaria and Amanita pantherina. MUS and IBO were extracted from mushrooms by aqueous methanol and derivatized with dansyl chloride (DNS-Cl). After extraction with ethyl acetate and evaporation of the solvent, the residue was ethylated with 1.25 M hydrogen chloride in ethanol. The resulting derivatives were quantified by high-performance liquid chromatography with UV detection and identified by liquid chromatography electrospray ionization tandem mass spectrometry. Calibration curves were linear in the range of 25-2500 ppm for MUS and 40-2500 ppm for IBO, respectively. This method was successfully applied to identify and quantify MUS and IBO in Amanita mushrooms naturally grown and circulated in the drug market.

  16. Characterization of aroma-active compounds in three Chinese Moutai liquors by gas chromatography-olfactometry, gas chromatography-mass spectrometry and sensory evaluation.

    Science.gov (United States)

    Niu, Yunwei; Chen, Xiaomei; Xiao, Zuobing; Ma, Ning; Zhu, Jiancai

    2017-04-01

    The aroma-active compounds in three Chinese Moutai liquors, aged 1 year, 15 years and 30 years were investigated in this study. The aroma compounds were analysed by gas chromatography-olfactometry (GC-O) coupled with gas chromatography-mass spectrometry (GC-MS). A total of 79 aroma compounds were identified. Aroma extract dilution analysis (AEDA) was further employed to identify the aroma-active compounds. A total of 35 aroma-active compounds with flavour dilution (FD) values ≧ 64 simultaneously in three Chinese Moutai liquors were quantitated. Among them, ethyl acetate, ethyl lactate and acetic acid appeared with the highest concentrations. They were all >1000 mg/L. Then, the relationships between the aroma-active compounds and seven sensory attributes were studied.

  17. Determination of endogenous ethanol in blood and breath by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Jones, A W; Mårdh, G; Anggård, E

    1983-01-01

    We describe methods for the determination of endogenous ethanol in biological specimens from healthy abstaining subjects. The analytical methods were headspace gas chromatography (GC) for plasma samples and gas chromatography-mass spectometry (GC/MS) with deuterium labelled species 2H3-ethanol and 2H5-ethanol as internal standards for breath analysis. Ethanol in rebreathed air was about 10% higher than in directly analysed end-expired alveolar air. Known volumes of rebreathed air were passed through a liquid-N2 freeze trap and the volatile constituents of breath were concentrated prior to analysis by GC or GC/MS. Besides endogenous ethanol, peaks were seen on the chromatograms for methanol, acetone and acetaldehyde as well as several as yet unidentified substances. The endogenous alcohols ethanol and methanol were confirmed from their mass chromatograms and the GC/MS profile also indicated the presence of endogenous propan-1-ol. The concentration of endogenous ethanol in plasma showed wide inter-subject variations ranging from below detection limits to 1.6 micrograms/ml (34.8 mumol/l) and with mean +/- SD of 0.39 +/- 0.45 micrograms/ml (8.5 +/- 9.8 mumol/l). We aim to characterise further the role of endogenous ethanol with the main focus on dynamic aspects such as the rate of formation and turnover.

  18. Targeted Chiral Analysis of Bioactive Arachidonic Acid Metabolites Using Liquid-Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Clementina Mesaros

    2012-04-01

    Full Text Available A complex structurally diverse series of eicosanoids arises from the metabolism of arachidonic acid. The metabolic profile is further complicated by the enantioselectivity of eicosanoid formation and the variety of regioisomers that arise. In order to investigate the metabolism of arachidonic acid in vitro or in vivo, targeted methods are advantageous in order to distinguish between the complex isomeric mixtures that can arise by different metabolic pathways. Over the last several years this targeted approach has become more popular, although there are still relatively few examples where chiral targeted approaches have been employed to directly analyze complex enantiomeric mixtures. To efficiently conduct targeted eicosanoid analyses, LC separations are coupled with collision induced dissociation (CID and tandem mass spectrometry (MS/MS. Product ion profiles are often diagnostic for particular regioisomers. The highest sensitivity that can be achieved involves the use of selected reaction monitoring/mass spectrometry (SRM/MS; whereas the highest specificity is obtained with an SRM transitions between an intense parent ion, which contains the intact molecule (M and a structurally significant product ion. This review article provides an overview of arachidonic acid metabolism and targeted chiral methods that have been utilized for the analysis of the structurally diverse eicosanoids that arise.

  19. Receptor-based high-throughput screening and identification of estrogens in dietary supplements using bioaffinity liquid-chromatography ion mobility mass spectrometry

    NARCIS (Netherlands)

    Aqai, P.; Gómez Blesa, N.; Major, H.; Pedotti, P.; Varani, L.; Ferrero, V.E.V.; Haasnoot, W.; Nielen, M.W.F.

    2013-01-01

    A high-throughput bioaffinity liquid chromatography-mass spectrometry (BioMS) approach was developed and applied for the screening and identification of recombinant human estrogen receptor a (ERa) ligands in dietary supplements. For screening, a semi-automated mass spectrometric ligand binding assay

  20. Chemical fingerprint of Ganmaoling granule by double-wavelength ultra high performance liquid chromatography and ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Lou, Qiong; Ye, Xiaolan; Zhou, Yingyi; Li, Hua; Song, Fenyun

    2015-06-01

    A method incorporating double-wavelength ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry was developed for the investigation of the chemical fingerprint of Ganmaoling granule. The chromatographic separations were performed on an ACQUITY UPLC HSS C18 column (2.1 × 50 mm, 1.8 μm) at 30°C using gradient elution with water/formic acid (1%) and acetonitrile at a flow rate of 0.4 mL/min. A total of 11 chemical constituents of Ganmaoling granule were identified from their molecular weight, UV spectra, tandem mass spectrometry data, and retention behavior by comparing the results with those of the reference standards or literature. And 25 peaks were selected as the common peaks for fingerprint analysis to evaluate the similarities among 25 batches of Ganmaoling granule. The results of principal component analysis and orthogonal projection to latent structures discriminant analysis showed that the important chemical markers that could distinguish the different batches were revealed as 4,5-di-O-caffeoylquinic acid, 3,5-di-O-caffeoylquinic acid, and 4-O-caffeoylquinic acid. This is the first report of the ultra high performance liquid chromatography chemical fingerprint and component identification of Ganmaoling granule, which could lay a foundation for further studies of Ganmaoling granule.

  1. Rapid screening for drugs of abuse in biological fluids by ultra high performance liquid chromatography/Orbitrap mass spectrometry.

    Science.gov (United States)

    Jagerdeo, Eshwar; Schaff, Jason E

    2016-08-01

    We present a UPLC(®)-High Resolution Mass Spectrometric method to simultaneously screen for nineteen benzodiazepines, twelve opiates, cocaine and three metabolites, and three "Z-drug" hypnotic sedatives in both blood and urine specimens. Sample processing consists of a high-speed, high-temperature enzymatic hydrolysis for urine samples followed by a rapid supported liquid extraction (SLE). The combination of ultra-high resolution chromatography with high resolution mass spectrometry allows all 38 analytes to be uniquely detected with a ten minute analytical run. Limits of detection for all target analytes are 3ng/mL or better, with only 0.3mL of specimen used for analysis. The combination of low sample volume with fast processing and analysis makes this method a suitable replacement for immunoassay screening of the targeted drug classes, while providing far superior specificity and better limits of detection than can routinely be obtained by immunoassay.

  2. Gas chromatographymass spectrometry of JWH-018 metabolites in urine samples with direct comparison to analytical standards

    Science.gov (United States)

    Emerson, Beth; Durham, Bill; Gidden, Jennifer; Lay, Jackson O.

    2013-01-01

    JWH-018 (1-pentyl-3-(1-naphthoyl)indole) is one of numerous potential aminoalkylindoles contained in products marketed as ‘K2’ or ‘Spice’. Investigation of the urinary metabolites from consumption of these compounds is important because they are banned in the United States and many European countries. An efficient extraction procedure and gas chromatographymass spectrometry (GC-MS) method were developed for detection of ‘K2’ metabolites in urine from individuals suspected of using these products. Analytical standards were used to elucidate the structure-specific mass spectral fragmentations and retention properties to confirm proposed identifications and support quantitative studies. A procedure for the synthesis of one of these metabolites (5-hydroxypentyl JWH-018) was also developed. Results are comparable to existing LC-MS/MS methods, with the same primary metabolites detected. The specific metabolite hydrolysis products include 4-hydroxpentyl, 5-hydroxypentyl, and N-pentanoic acid derivatives. PMID:23683902

  3. Identification of monomenthyl succinate, monomenthyl glutarate, and dimenthyl glutarate in nature by high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Hiserodt, Richard D; Adedeji, Jide; John, T V; Dewis, Mark L

    2004-06-01

    Menthol, menthone, and other natural compounds provide a cooling effect and a minty flavor and have found wide application in chewing gum and oral care products. Monomenthyl succinate, monomenthyl glutarate, and dimenthyl glutarate provide a cooling effect without the burning sensation associated with menthol. Additionally, because they do not have a distinct flavor, they can be used in applications other than mint flavors. Because these menthyl esters have not been reported in nature, we undertook to identify a natural source for these cooling compounds. Using high performance liquid chromatography-tandem mass spectrometry, monomenthyl succinate was identified in Lycium barbarum and Mentha piperita, and monomenthyl glutarate and dimenthyl glutarate were identified in Litchi chinesis. The identifications were based on the correlation of mass spectrometric and chromatographic retention time data for the menthyl esters in the extracts with authentic standards which resulted in a 99.980% confidence in the identifications.

  4. Characterization of isomeric VX nerve agent adducts on albumin in human plasma using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Saeidian, Hamid; Mirkhani, Valioallah; Mousavi Faraz, Sajjad; Taghi Naseri, Mohammad; Babri, Mehran

    2015-01-01

    This study includes the characterization of isomeric VX organophosphorus adducts on albumin in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). VX or its structural isomers were spiked into a vial containing plasma in order to obtain phosphorylated albumin. After pronase and trypsin digestion, the resulting solutions were analyzed to confirm adduct formation with the amino acid tyrosine on the albumin in human plasma. The LC-MS/MS experiments show that VX and its isomers can be attached to tyrosine on the albumin in human blood. Mass spectrometric studies revealed some interesting fragmentation pathways during the ionization process, such as ethylene, formic acid and ammonia elimination and an intermolecular electrophilic aromatic substitution reaction. The proposed mechanisms for the formation of the fragments were confirmed through the analysis of fragments of deuterated adducts.

  5. Measurement of choline and choline metabolite concentrations using high-pressure liquid chromatography and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Pomfret, E A; daCosta, K A; Schurman, L L; Zeisel, S H

    1989-07-01

    We have developed a reproducible and sensitive procedure for the isolation and measurement of choline, phosphocholine, glycerophosphocholine, phosphatidylcholine, lysophosphatidylcholine and acetylcholine in a single 100-mg sample of biological tissue. Tissues were spiked with 14C-methyl- and 2H-methyl- or 15N-choline labeled internal standards for each compound. They were extracted with chloroform/methanol/water and the aqueous and organic phases were dried. The organic phase was resuspended in chloroform/methanol (1/1, v/v) and an aliquot was applied to a silica-gel thin-layer chromatography plate. The plate was developed in chloroform/methanol/water (65/30/4, v/v). Segments which cochromatographed with external standards of phosphatidylcholine and lysophosphatidylcholine were stained, scraped, and hydrolyzed in 6 M methanolic-HCl at 80 degrees C for 60 min, liberating free choline. The aqueous phase was resuspended in methanol/water and injected onto a silica HPLC column. Choline and its metabolites were eluted using a binary nonlinear gradient of acetonitrile/ethanol/acetic acid/1 M ammonium acetate/water/0.1 M sodium phosphate (800/68/2/3/127/10, v/v changing to 400/68/44/88/400/10, v/v). Peaks were detected with an on-line radiometric detector, collected, and dried under vacuum. Each choline ester was digested in 6 M HCl at 80 degrees C to form choline. Choline was then converted to the propionyl ester and demethylated with sodium benzenethiolate. This volatile derivative was then isolated using gas chromatography and measured with a mass selective detector. Deuterated internal standards were used to correct for variations in recovery. Choline, glycerophosphocholine, phosphocholine, phosphatidylcholine, lysophosphatidylcholine, and acetylcholine were measured in rat liver, heart, muscle, kidney, plasma, red blood cells, and brain and in human plasma.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Determination of alkylphenol and alkylphenolethoxylates in biota by liquid chromatography with detection by tandem mass spectrometry and fluorescence spectroscopy

    Science.gov (United States)

    Schmitz-Afonso, I.; Loyo-Rosales, J.E.; de la Paz Aviles, M.; Rattner, B.A.; Rice, C.P.

    2003-01-01

    A quantitative method for the simultaneous determination of octylphenol, nonylphenol and the corresponding ethoxylates (1 to 5) in biota is presented. Extraction methods were developed for egg and fish matrices based on accelerated solvent extraction followed by a solid-phase extraction cleanup, using octadecylsilica or aminopropyl cartridges. Identification and quantitation were accomplished by liquid chromatography-electrospray tandem mass spectrometry (LC-MS-MS) and compared to the traditional liquid chromatography with fluorescence spectroscopy detection. LC-MS-MS provides high sensitivity and specificity required for these complex matrices and an accurate quantitation with the use of 13C-labeled internal standards. Quantitation limits by LC-MS-MS ranged from 4 to 12 ng/g in eggs, and from 6 to 22 ng/g in fish samples. These methods were successfully applied to osprey eggs from the Chesapeake Bay and fish from the Great Lakes area. Total levels found in osprey egg samples were up to 18 ng/g wet mass and as high as 8.2 ug/g wet mass in the fish samples.

  7. Quantitative Analysis and Fingerprint Profiles for Quality Control of Fructus Schisandrae by Gas Chromatography: Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Yong-Gang Xia

    2014-01-01

    Full Text Available This paper describes a simple, rapid, and effective quality assessment method for Fructus Schisandrae by gas chromatography-mass spectrum (GC-MS. The method was established by using specific lignan fingerprint profiles and quantitation of characteristic compounds in this herbal medicine. The GC-MS fingerprints of 15 batches of Schisandra samples from different regions of China showed similar lignan profiles. Five peaks were selected as characteristic peaks, and all of these were identified by using GC-MS techniques. The relative retention times of these characteristic peaks in the GC-MS fingerprint were established as an important parameter for identification of Schisandra samples. Meanwhile, relative peak areas may be a feasible approach to discriminate the S. chinensis and S. sphenanthera. Finally, these pharmacologically active constituents in the titled plant, schisandrins A–C and schizandrols A and B, were quantitatively determined using a validated GC-MS method.

  8. Liquid chromatography coupled with time-of-flight and ion trap mass spectrometry for qualitative analysis of herbal medicines

    Institute of Scientific and Technical Information of China (English)

    Xiao-Fei Chen; Hai-Tang Wu; Guang-Guo Tan; Zhen-Yu Zhu; Yi-Feng Chai

    2011-01-01

    With the expansion of herbal medicine (HM) market, the issue on how to apply up-to- date analytical tools on qualitative analysis of HMs to assure their quality, safety and efficacy has been arousing great attention. Due to its inherent characteristics of accurate mass measurements and multiple stages analysis, the integrated strategy of liquid chromatography (LC) coupled with time-of-flight mass spectrometry (TOF-MS) and ion trap mass spectrometry (IT-MS) is well-suited to be performed as qualitative analysis tool in this field. The purpose of this review is to provide an overview on the potential of this integrated strategy, including the review of general features of LC-IT-MS and LC-TOF-MS, the advantages of their combination, the common procedures for structure elucidation, the potential of LC-hybrid-IT-TOF/MS and also the summary and discussion of the applications of the integrated strategy for HM qualitative analysis (2006-2011). The advantages and future developments of LC coupled with IT and TOF-MS are highlighted.

  9. Highly specific quantification of ergotamine in urine, blood, and hair samples by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Favretto, Donata; Frison, Giampietro; Vogliardi, Susanna; Ferrara, Santo Davide

    2007-06-01

    Ergotamine has been used for therapeutic purposes since the 1950s, usually to treat vascular headache. It is highly toxic and in large, repeated doses can produce all the symptoms of ergot poisoning. A selective and sensitive method, based on liquid chromatography-tandem mass spectrometry (LC-MS2), has been developed for quantifying ergotamine in biological fluids with use of a quick and easy sample preparation. Ergotamine and the internal standard, trideuterated lysergic acid diethylamide, were extracted from human urine, blood, and hair by means of liquid-liquid extraction at alkaline pH. Gradient elution on a cyanopropyl column was used for chromatographic separation. Positive ion electrospray ionization and tandem mass spectrometry determination by collision-induced dissociation were performed in an ion trap mass spectrometer. The method was validated and successfully applied to a case of iatrogenic ergotism resulting from the intake of ergotamine tartrate for treating headache. For the first time, ergotamine was identified and quantified in hair. The ergotamine concentrations measured were 320 pg/mL in blood, 100 pg/mL in urine, 24 pg/mg in proximal hair, and 15 pg/mg in distal hair.

  10. Quantification of citalopram or escitalopram and their demethylated metabolites in neonatal hair samples by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Frison, Giampietro; Favretto, Donata; Vogliardi, Susanna; Terranova, Claudio; Ferrara, Santo Davide

    2008-08-01

    Citalopram and escitalopram are highly selective serotonin reuptake inhibitors widely used in the treatment of depression. They exhibit adverse drug reactions and side effects, however, and the development of specific methods for their determination is of great interest in clinical and forensic toxicology. A liquid chromatography-tandem mass spectrometry method has been developed and validated for the assay of citalopram, escitalopram, and their demethylated metabolites in 10-mg hair samples. The analytes were extracted by incubation in methanol and liquid/liquid extraction with diethyl ether/dichloromethane. Gradient elution on a narrow bore C18 column was realized using clomipramine-d3 as an internal standard. Positive ion electrospray ionization and tandem mass spectrometry determination by collision-induced dissociation were performed in an ion trap mass spectrometer. The method exhibited a linear range of 25 to 2000 pg/mg, a quantification limit of 25 pg/mg for all analytes, relative standard deviations in the range of 12.10 to 9.80 (intraassay), and 13.80 to 11.78 (interassay), and accuracies (as percent recovery of the spiked standards) in the range of 90% to 110%; it was applied to the determination of citalopram and escitalopram and their metabolites in hair samples of two newborns to document their in utero exposure to the drugs. The method proved suitable for neonatal hair analysis of citalopram or escitalopram and was applied to two real cases of gestational exposure.

  11. High-performance liquid chromatography accelerator mass spectrometry: correcting for losses during analysis by internal standardization.

    Science.gov (United States)

    Lappin, G; Simpson, M; Shishikura, Y; Garner, C

    2008-07-01

    A method was developed to account for analytical losses of (14)C-analyte when determining the concentration in biological samples using chromatographic separation and analysis by accelerator mass spectrometry. From the equations of J. Vogel and A.H. Love (in: A.L. Burlingame (Ed.), Methods in Enzymology, Academic Press, New York, 2005), new equations were derived to describe the isotopic dilution of a chromatographically isolated (14)C-analyte. The analytical recovery for each sample was determined by the use of the UV response for nonlabeled analyte, as an internal standard against a standard curve. The slope of the curve was substituted into the equations to provide a method of accurately determining the analyte concentration.

  12. Assessment of oil weathering by gas chromatography-mass spectrometry, time warping and principal component analysis

    DEFF Research Database (Denmark)

    Malmquist, Linus M.V.; Olsen, Rasmus R.; Hansen, Asger B.

    2007-01-01

    Detailed characterization and understanding of oil weathering at the molecular level is an essential part of tiered approaches for forensic oil spill identification, for risk assessment of terrestrial and marine oil spills, and for evaluating effects of bioremediation initiatives. Here......, a chemometricbased method is applied to data from two in vitro experiments in order to distinguish the effects of evaporation and dissolution processes on oil composition. The potential of the method for obtaining detailed chemical information of the effects from evaporation and dissolution processes, to determine...... weathering state and to distinguish between various weathering processes is investigated and discussed. The method is based on comprehensive and objective chromatographic data processing followed by principal component analysis (PCA) of concatenated sections of gas chromatography–mass spectrometry...

  13. Ultra-Performance Liquid Chromatography Tandem Mass Spectrometry Measurement of Caffeine in Caffeine-Laced Pants and in Urine and Skin of a Pants User

    OpenAIRE

    Manuela Pellegrini; Daniela De Orsi; Carmine Guarino; Maria Concetta Rotolo; Rita di Giovannandrea; Roberta Pacifici; Simona Pichini

    2014-01-01

    A fast and sensitive ultra-performance liquid chromatography tandem mass spectrometry method was developed for the measurement of caffeine in caffeine-laced pants and in urine and skin of a pants user. The substance and its internal standard (N-ethylnorcotinine) were separated by reversed phase chromatography with 5 mM ammonium formate pH 3.0 and 0.3% formic acid in acetonitrile mobile phase (83:17 v/v) by isocratic elution and detected by tandem mass spectrometry operated in multiple reacti...

  14. [Non-target screening of organic pollutants in sediments and sludges using gas chromatography-mass spectrometry and automated mass spectral deconvolution].

    Science.gov (United States)

    Wang, Gang; Ma, Huilian; Wang, Longxing; Chen, Jiping; Hou, Xiaohong

    2015-12-01

    A screening method in the combination of ultrasonic extraction, gas chromatography-mass spectrometry detection and automated mass spectrometry deconvolution technique was developed for non-target screening of non-polar and weak polar pollutants in sediments and sludges. The samples were extracted by ultrasonication for 20 min using dichloromethane for three times. The extraction solutions were cleaned-up by gel permeation chromatography and a silica gel column, and then 3 g of copper powder was used to remove the sulfur by ultrasonication for 10 min. Parallel experiments were carried out for 5 times and the RSDs were ranged from 5.8% to 14.9%. Automated mass spectral deconvolution & identification system (AMDIS) would improve the resolution of overlapping peaks, and identify the pure mass spectrum of the analytes in the cases of stronger background interference and co-extracted substances covering. Standard spectrum databases, such as NISTDRUG, NISTEPA, NISTFDA, Mass Spectral Library, etc, would qualitatively identify the organic pollutants in the samples. As a result, a total of 290 organic pollutants were identified, of which 190 and 153 pollutants were found in sediments and sludges, respectively. The identified pollutants included the Environmental Protection Agency (EPA) priority pollutants, pharmaceuticals, herbicides, antioxidants, intermediates, organic solvents and chemical raw materials. The proposed method is proved to be a promising one for non-target screening of complex matrix samples with the advantages of higher sensitivity and better repeatability.

  15. Qualitative profiling and quantification of neonicotinoid metabolites in human urine by liquid chromatography coupled with mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Kumiko Taira

    Full Text Available Neonicotinoid pesticides have been widely applied for the production of fruits and vegetables, and occasionally detected in conventionally grown produce. Thus oral exposure to neonicotinoid pesticides may exist in the general population; however, neonicotinoid metabolites in human body fluids have not been investigated comprehensively. The purpose of this study is the qualitative profiling and quantitative analysis of neonicotinoid metabolites in the human spot urine by liquid chromatography coupled with mass spectrometry (LC/MS. Human urine samples were collected from three patients suspected of subacute exposure to neonicotinoid pesticides. A qualitative profiling of urinary metabolites was performed using liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS with a database of nominal molecular weights of 57 known metabolites of three neonicotinoid pesticides (acetamiprid, Imidacloprid, and clothianidin, as well as the parent compounds. Then a quantitative analysis of selected urinary metabolites was performed using liquid chromatography/tandem mass spectrometry (LC/MS/MS with a standard pesticide and metabolite, which were detected by the qualitative profiling. The result of qualitative profiling showed that seven metabolites, i.e. an acetamiprid metabolite, N-desmethyl-acetamiprid; three Imidacloprid metabolites, 5-hydroxy-Imidacloprid, 4,5-dihydroxy-imidacloprid, 4,5-dehydro-Imidacloprid; a common metabolite of acetamiprid and Imidacloprid, N-(6-chloronicotinoyl-glycine; and two clothianidin metabolites, N-desmethyl-clothianidin, N-(2-(methylsulfanylthiazole-5-carboxyl-glycine, as well as acetamiprid, were detected in the urine of three cases. The result of the quantitative analysis showed N-desmethyl-acetamiprid was determined in the urine of one case, which had been collected on the first visit, at a concentration of 3.2 ng/mL. This is the first report on the qualitative and quantitative detection of N-desmethyl-acetamiprid in

  16. Determination of mepitiostane metabolites in human urine by liquid chromatography/tandem mass spectrometry for sports drug testing.

    Science.gov (United States)

    Okano, Masato; Sato, Mitsuhiko; Kojima, Asami; Kageyama, Shinji

    2015-11-10

    Mepitiostane (2α,3α-epithio-17β-(1-methoxycyclopentyloxy)-5α-androstane), which is a prodrug of epitiostanol (2α,3α-epitio-5α-androstane-17β-ol), is an epitiosteroid having anti-estrogenic and weak androgenic anabolic activities. The World Anti-Doping Agency prohibits the misuse of mepitiostane by athletes. Detection of the urinary metabolites epitiostanol sulfoxide and epitiostanol was studied using liquid chromatography/mass spectrometry (LC-MS) for doping control purposes. The use of LC-MS provided advantages over gas chromatography/mass spectrometry for detecting heat labile steroids because epitiostanol and epitiostanol sulfoxide were primarily pyrolized to 5α-androst-2-en-17β-ol. The method consists of enzymatic hydrolysis using β-glucuronidase (Escherichia coli), liquid-liquid extraction, and subsequent ultra-performance liquid chromatography/electrospray-tandem mass spectrometry. Epitiostanol sulfoxide was determined at urinary concentrations of 0.5-50ng/mL, recovery was 76.2-96.9%, and assay precision was calculated as 0.9-1.7% (intra-day) and 2.0-6.6% (inter-day). Epitiostanol was determined at urinary concentrations of 0.5-50ng/mL, recovery was 26.1-35.6% and assay precision was calculated as 4.1-4.6% (intra-day) and 3.3-8.5% (inter-day). The limits of detection for epitiostanol sulfoxide and epitiostanol were 0.05ng/mL and 0.10ng/mL, respectively. Epitiostanol sulfoxide and epitiostanol, as their gluco-conjugates, were identified in human urine after oral administration of 10mg mepitiostane. Epitiostanol sulfoxide and epitiostanol could be detected up to 48h and 24h after administration, respectively. The results showed that the detection window of epitiostanol is much shorter than that of epitiostanol sulfoxide. The LC-MS detection of urinary epitiostanol sulfoxide, a specific metabolite with a sulphur atom in its molecular structure, is likely to be able to identify the abuse of mepitiostane.

  17. Accurate screening for synthetic preservatives in beverage using high performance liquid chromatography with time-of-flight mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Li Xiuqin; Zhang Feng; Sun Yanyan; Yong Wei [Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Jia 3, Gaobeidian North Road, Beijing 100025 (China); Chu Xiaogang [Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Jia 3, Gaobeidian North Road, Beijing 100025 (China)], E-mail: lixq_sypu@yahoo.com; Fang Yanyan; Zweigenbaum, Jerry [Agilent Technologies, Inc., 2850 Centerville Road, Wilmington, Delaware (United States)

    2008-02-11

    In this study, liquid chromatography time-of-flight mass spectrometry (HPLC/TOF-MS) is applied to qualitation and quantitation of 18 synthetic preservatives in beverage. The identification by HPLC/TOF-MS is accomplished with the accurate mass (the subsequent generated empirical formula) of the protonated molecules [M + H]+ or the deprotonated molecules [M - H]-, along with the accurate mass of their main fragment ions. In order to obtain sufficient sensitivity for quantitation purposes (using the protonated or deprotonated molecule) and additional qualitative mass spectrum information provided by the fragments ions, segment program of fragmentor voltages is designed in positive and negative ion mode, respectively. Accurate mass measurements are highly useful in the complex sample analyses since they allow us to achieve a high degree of specificity, often needed when other interferents are present in the matrix. The mass accuracy typically obtained is routinely better than 3 ppm. The 18 compounds behave linearly in the 0.005-5.0 mg.kg{sup -1} concentration range, with correlation coefficient >0.996. The recoveries at the tested concentrations of 1.0 mg.kg{sup -1}-100 mg.kg{sup -1} are 81-106%, with coefficients of variation <7.5%. Limits of detection (LODs) range from 0.0005 to 0.05 mg.kg{sup -1}, which are far below the required maximum residue level (MRL) for these preservatives in foodstuff. The method is suitable for routine quantitative and qualitative analyses of synthetic preservatives in foodstuff.

  18. Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry.

    Science.gov (United States)

    Miyaguchi, Hajime

    2016-09-20

    An improved version of a polymerase chain reaction (PCR)-restriction fragment length polymorphism (RFLP) method for genotyping toxic pufferfish species by liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) is described. DNA extraction is carried out using a silica membrane-based DNA extraction kit. After the PCR amplification using a detergent-free PCR buffer, restriction enzymes are added to the solution without purifying the reaction solution. A reverse-phase silica monolith column and a Fourier transform high resolution mass spectrometer having a modified Kingdon trap analyzer are employed for separation and detection, respectively. The mobile phase, consisting of 400 mM 1,1,1,3,3,3-hexafluoro-2-propanol, 15 mM triethylamine (pH 7.9) and methanol, is delivered at a flow rate of 0.4 ml/min. The cycle time for LC/ESI-MS analysis is 8 min including equilibration of the column. Deconvolution software having an isotope distribution model of the oligonucleotide is used to calculate the corresponding monoisotopic mass from the mass spectrum. For analysis of oligonucleotides (range 26-79 nucleotides), mass accuracy was 0.62 ± 0.74 ppm (n = 280) and excellent accuracy and precision were sustained for 180 hr without use of a lock mass standard.

  19. Accurate screening for synthetic preservatives in beverage using high performance liquid chromatography with time-of-flight mass spectrometry.

    Science.gov (United States)

    Li, Xiu Qin; Zhang, Feng; Sun, Yan Yan; Yong, Wei; Chu, Xiao Gang; Fang, Yan Yan; Zweigenbaum, Jerry

    2008-02-11

    In this study, liquid chromatography time-of-flight mass spectrometry (HPLC/TOF-MS) is applied to qualitation and quantitation of 18 synthetic preservatives in beverage. The identification by HPLC/TOF-MS is accomplished with the accurate mass (the subsequent generated empirical formula) of the protonated molecules [M+H]+ or the deprotonated molecules [M-H]-, along with the accurate mass of their main fragment ions. In order to obtain sufficient sensitivity for quantitation purposes (using the protonated or deprotonated molecule) and additional qualitative mass spectrum information provided by the fragments ions, segment program of fragmentor voltages is designed in positive and negative ion mode, respectively. Accurate mass measurements are highly useful in the complex sample analyses since they allow us to achieve a high degree of specificity, often needed when other interferents are present in the matrix. The mass accuracy typically obtained is routinely better than 3 ppm. The 18 compounds behave linearly in the 0.005-5.0mg.kg(-1) concentration range, with correlation coefficient >0.996. The recoveries at the tested concentrations of 1.0mg.kg(-1)-100mg.kg(-1) are 81-106%, with coefficients of variation preservatives in foodstuff. The method is suitable for routine quantitative and qualitative analyses of synthetic preservatives in foodstuff.

  20. Qualitative and Quantitative Analysis of Major Triterpenoids in Alismatis Rhizoma by High Performance Liquid Chromatography/Diode-Array Detector/Quadrupole-Time-of-Flight Mass Spectrometry and Ultra-Performance Liquid Chromatography/Triple Quadrupole Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Wanli Zhao

    2015-07-01

    Full Text Available Alismatis Rhizoma (AMR is a well-known natural medicine with a long history in Chinese medicine and has been commonly used for treating a wide range of ailments related to dysuria, edema, nephropathy, hyperlipidaemia, diabetes, inflammation as well as tumors in clinical applications. Most beneficial effects of AMR are attributed to the presence of protostane terpenoids, the major active ingredients of Alismatis Rhizoma (AMR. In this study, a systematic high performance liquid chromatography/diode-array detector/quadrupole-time-of-flight mass spectrometry (HPLC-DAD-Q-TOF MS and ultra-performance liquid chromatography/triple quadrupole mass spectrometry (UPLC-QqQ MS method was developed for qualitative and quantitative analyses of the major AMR triterpenoids. First, a total of 25 triterpenoid components, including 24 known compounds and one new compound were identified by comparison with UV spectra, molecular ions and fragmentation behaviors of reference standards or the literature. Second, an efficient method was established for the rapid simultaneous determination of 14 representative triterpenoids by UPLC-QqQ MS. Forty-three batches of AMR were analyzed with linearity (r, 0.9980–0.9999, intra-day precision (RSD, 1.18%–3.79%, inter-day precision (RSD, 1.53%–3.96%, stability (RSD, 1.32%–3.97%, repeatability (RSD, 2.21%–4.25%, and recovery (98.11%–103.8%. These results indicated that new approaches combining HPLC-DAD-Q-TOF MS and UPLC-QqQ MS are applicable in the qualitative and quantitative analysis of AMR.

  1. Identification of oxidative degradates of the thrombin inhibitor, 3-(2-phenethylamino)-6-methyl-1-(2-amino-6-methyl-5-methyleneca rboxamidomethylpyridinyl)pyrazinone, using liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Wu, Y; Chen, X; Gier, L; Almarsson, O; Ostovic, D; Loper, A E

    1999-07-01

    Liquid chromatography/mass spectrometry was used to identify reaction products from a solution of 3-(2-phenethylamino)-6-methyl-1-(2-amino-6-methyl-5-methyleneca rboxamidomethylpyridinyl)pyrazinone (L-375,378) and hydrogen peroxide, a system that generates high levels of the oxidative degradates which form in the tablets and intravenous (i.v.) solutions of L-375,378. Two major hydrogen peroxide reaction products of L-375,378 (m/z 407) with m/z values of 369 and 370 were separated and identified. Both compounds were products of ring opening with elimination of three carbon atoms from the center pyrazinone ring. The structural assignments for these two products were alpha-amidinoamide and alpha-diamide compounds, respectively. In addition, five products (m/z 423) with a molecular weight 16 Da greater than that for L-375,378 were separated. Further liquid chromatography/tandem mass spectrometry experiments indicated that three of these M + 16 products were phenolic derivatives of L-375,378. Among them, the para-hydroxy compound has been verified using an authentic standard. The other two phenolic compounds were believed to be the meta- and ortho-hydroxy derivatives of L-375,378. The fourth M + 16 product was derived from hydroxylation of the methyl group on the center pyrazinone ring. The fifth M + 16 product was derived from oxidation on the aminopyridine moiety, most likely N-oxide of the pyridine ring. Other minor hydrogen peroxide reaction products were not studied in detail because they did not appear in tablets or i.v. formulations.

  2. SFC-APLI-(TOF)MS: Hyphenation of Supercritical Fluid Chromatography to Atmospheric Pressure Laser Ionization Mass Spectrometry.

    Science.gov (United States)

    Klink, Dennis; Schmitz, Oliver Johannes

    2016-01-05

    Atmospheric-pressure laser ionization mass spectrometry (APLI-MS) is a powerful method for the analysis of polycyclic aromatic hydrocarbon (PAH) molecules, which are ionized in a selective and highly sensitive way via resonance-enhanced multiphoton ionization. APLI was presented in 2005 and has been hyphenated successfully to chromatographic separation techniques like high performance liquid chromatography (HPLC) and gas chromatography (GC). In order to expand the portfolio of chromatographic couplings to APLI, a new hyphenation setup of APLI and supercritical-fluid chromatography (SFC) was constructed and aim of this work. Here, we demonstrate the first hyphenation of SFC and APLI in a simple designed way with respect to different optimization steps to ensure a sensitive analysis. The new setup permits qualitative and quantitative determination of native and also more polar PAH molecules. As a result of the altered ambient characteristics within the source enclosure, the quantification of 1-hydroxypyrene (1-HP) in human urine is possible without prior derivatization. The limit of detection for 1-HP by SFC-APLI-TOF(MS) was found to be 0.5 μg L(-1), which is lower than the 1-HP concentrations found in exposed persons.

  3. Determination of quinolone residues in shrimp using liquid chromatography with fluorescence detection and residue confirmation by mass spectrometry.

    Science.gov (United States)

    Karbiwnyk, Christine M; Carr, Lori E; Turnipseed, Sherri B; Andersen, Wendy C; Miller, Keith E

    2007-07-23

    The quinolones, oxolinic acid (OXO), flumequine (FLU), and nalidixic acid (NAL), are antibacterial drugs effective against gram-negative bacteria. Quinolones are used in both human and veterinary medicine, but are currently not approved by the U.S. Food and Drug Administration for use in food fish. A liquid chromatography-fluorescence (LC-FL) method was developed to determine OXO, FLU, and NAL residues in shrimp. An additional liquid chromatography-mass spectrometry (LC-MS(n)) method was created to confirm these residues using the same sample extract. Samples were prepared with a simple ethyl acetate extraction followed by solvent exchange into 0.2% formic acid and cleaned-up with hexane. Reverse phase chromatography was used to separate the three compounds in both procedures. For the LC-FL determinative method, fluorescence emission was monitored at 369 nm with excitation at 327 nm. With electrospray ionization, the three most abundant ions from the MS3 product ion spectrum were used to identify OXO, FLU, and NAL in the confirmation procedure. Shrimp samples fortified at levels ranging from 7.5 to 100 ng g(-1) were used to validate both methods.

  4. Qualitative and quantitative two-dimensional thin-layer chromatography/high performance liquid chromatography/diode-array/electrospray-ionization-time-of-flight mass spectrometry of cholinesterase inhibitors.

    Science.gov (United States)

    Mroczek, Tomasz

    2016-09-10

    Recently launched thin-layer chromatography-mass spectrometry (TLC-MS) interface enabling extraction of compounds directly from TLC plates into MS ion source was unusually extended into two-dimensional thin-layer chromatography/high performance liquid chromatography (2D, TLC/HPLC) system by its a direct connection to a rapid resolution 50×2.1mm, I.D. C18 column compartment followed by detection by diode array (DAD) and electrospray ionisation time-of-flight mass spectrometry (ESI-TOF-MS). In this way, even not separated bands of complicated mixtures of natural compounds could be analysed structurally, only within 1-2min after development of TLC plates. In comparison to typically applied TLC-MS interface, no ion suppression for acidic mobile phases was observed. Also, substantial increase in ESI-TOF-MS sensitivities and quality of spectra, were noticed. It has been utilised in combination with TLC- based bioautographic approaches of acetylcholinesterase (AChE) inhibitors, However, it can be also applied in any other procedures related to bioactivity (e.g. 2,2-Diphenyl-1-picryl-hydrazyl-DPPH screen test for radicals). This system has been also used for determination of half maximal inhibitory concentration (IC50 values) of the active inhibitor-galanthamine, as an example. Moreover, AChE inhibitory potencies of some of purified plant extracts, never studied before, have been quantitatively measured. This is first report of usage such the 2D TLC/HPLC/MS system both for qualitative and quantitative evaluation of cholinesterase inhibitors in biological matrices.

  5. Discrimination of eight chloramphenicol isomers by liquid chromatography tandem mass spectrometry in order to investigate the natural occurence of chloramphenicol

    NARCIS (Netherlands)

    Berendsen, B.J.A.; Zuidema, T.; Jong, de J.; Stolker, A.A.M.; Nielen, M.W.F.

    2011-01-01

    This paper describes the discrimination of eight different isomers of chloramphenicol (CAP), an antibiotic banned for use in food producing animals, by reversed phase and chiral liquid chromatography in combination with tandem mass spectrometric detection. Previously, by liquid chromatography couple

  6. Sensitive quantification of omeprazole and its metabolites in human plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Hofmann, Ute; Schwab, Matthias; Treiber, Gerd; Klotz, Ulrich

    2006-02-02

    A sensitive method was developed for the simultaneous determination of omeprazole and its major metabolites 5-hydroxyomeprazole and omeprazole sulfone in human plasma by HPLC-electrospray mass spectrometry. Following liquid-liquid extraction HPLC separation was achieved on a ProntoSil AQ, C18 column using a gradient with 10 mM ammonium acetate in water (pH 7.25) and acetonitrile. The mass spectrometer was operated in the selected ion monitoring mode using the respective MH(+) ions, m/z 346 for omeprazole, m/z 362 for 5-hydroxy-omeprazole and omeprazol-sulfone and m/z 300 for the internal standard (2-{[(3,5-dimethylpyridine-2-yl)methyl]thio}-1H-benzimidazole-5-yl)methanol. The limit of quantification (LOQ) achieved with this method was 5 ng/ml for 5-hydroxyomeprazole and 10 ng/ml for omeprazole and omeprazole-sulfone using 0.25 ml of plasma. Intra- and inter-assay variability was below 11% over the whole concentration range from 5 to 250 ng/ml for 5-hydroxyomeprazol and from 10 to 750 ng/ml for omeprazole and omeprazole-sulfone. The method was successfully applied to the determination of pharmacokinetic parameters of esomeprazole and the two major metabolites after a single dose and under steady state conditions.

  7. [Determination of acrylamide in fried starchy foods by gas chromatography-mass spectrometry].

    Science.gov (United States)

    Zhong, Weike; Chen, Dongdong; Yong, Wei; Liu, Zhiming; Qiu, Yueming; Tang, Yingzhang

    2005-05-01

    A method was developed for the determination of acrylamide in fried starchy foods using isotope dilution gas chromatograpy-selected mass spectrometry (GC-MS). The acrylamide was extracted from samples by water, then centrifuged and cleaned up by a column of graphitized carbon black. Acrylamide was derivatized through bromination at low pH and low temperature and determined by GC-MS. With the aid of the 13C-substituted acrylamide internal standard, the mass spectrum in GC-MS was interpreted, and the content of acrylamide was measured. The limit of quantitative detection (S/N > 10) was 5 microg/kg and the recovery was in the range of 90%-105% and relative standard deviation is 6.3%. The levels of acrylamide in some fried foodstuffs such as French fries was surveyed using the method. French fries were found to contain 278-4518 microg/kg acrylamide. It means that the content of acrylamide in French fries is 10,000 times higher than the drinking water guideline of World Health Organization for acrylamide.

  8. Detection of 10 sweeteners in various foods by liquid chromatography/tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Chui-Shiang Chang

    2014-09-01

    Full Text Available The analytical method for sweeteners in various food matrixes is very important for food quality control and regulation enforcement. A simple and rapid method for the simultaneous determination of 10 sweeteners [acesulfame potassium (ACS-K, aspartame (ASP, cyclamate (CYC, dulcin (DUL, glycyrrhizic acid (GA, neotame (NEO, neohesperidin dihydrochalcone (NHDC, saccharin (SAC, sucralose (SCL, and stevioside (STV] in various foods by liquid chromatography/tandem mass chromatography (LC–MS/MS was developed. The chromatographic separation was performed on a Phenomenex Luna Phenyl-Hexyl (5 μm, 4.6 mm × 150 mm column with gradient elution of 10 mM ammonium acetate in water and 10 mM ammonium acetate in methanol. The recoveries of the 10 sweeteners were between 75% and 120%, and the coefficients of variation were less than 20%. The limits of quantification were 0.5 μg/kg for NHDC and SCL. For the other sweeteners, the limits of quantification were 0.1 μg/kg. Compared to the traditional high-performance liquid chromatography method, the LC–MS/MS method could provide better sensitivity, higher throughput, enhanced specificity, and more sweeteners analyzed in a single run. The samples included 27 beverages (16 alcoholic and 11 nonalcoholic beverages and 15 pickled foods (1 pickled pepper, 3 candies, and 11 candied fruits. Two remanufactured wines were found to contain 7.2, 8.5 μg/g SAC and 126.5, 123 μg/g CYC, respectively. ACS-K, ASP, SCL, and NEO were detected in five beverages and drinks. The pickled peppers and candied fruits were found to contain SAC, GA, CYC, ASP, STV, NEO, and ACS-K. The wine with sweeteners detected was remanufactured wine, not naturally fermented wine. Therefore, the ingredient label for the sweeteners of remanufactured wine should be regulated by the proper authority for inspection of sweeteners.

  9. Directly coupled high-performance liquid chromatography-accelerator mass spectrometry measurement of chemically modified protein and peptides.

    Science.gov (United States)

    Thomas, Avi T; Stewart, Benjamin J; Ognibene, Ted J; Turteltaub, Kenneth W; Bench, Graham

    2013-04-02

    Quantitation of low-abundance protein modifications involves significant analytical challenges, especially in biologically important applications, such as studying the role of post-translational modifications in biology and measurement of the effects of reactive drug metabolites. (14)C labeling combined with accelerator mass spectrometry (AMS) provides exquisite sensitivity for such experiments. Here, we demonstrate real-time (14)C quantitation of high-performance liquid chromatography (HPLC) separations by liquid sample accelerator mass spectrometry (LS-AMS). By enabling direct HPLC-AMS coupling, LS-AMS overcomes several major limitations of conventional HPLC-AMS, where individual HPLC fractions must be collected and converted to graphite before measurement. To demonstrate LS-AMS and compare the new technology to traditional solid sample AMS (SS-AMS), reduced and native bovine serum albumin (BSA) was modified by (14)C-iodoacetamide, with and without glutathione present, producing adducts on the order of 1 modification in every 10(6) to 10(8) proteins. (14)C incorporated into modified BSA was measured by solid carbon AMS and LS-AMS. BSA peptides were generated by tryptic digestion. Analysis of HPLC-separated peptides was performed in parallel by LS-AMS, fraction collection combined with SS-AMS, and (for peptide identification) electrospray ionization and tandem mass spectrometry (ESI-MS/MS). LS-AMS enabled (14)C quantitation from ng sample sizes and was 100 times more sensitive to (14)C incorporated in HPLC-separated peptides than SS-AMS, resulting in a lower limit of quantitation of 50 zmol (14)C/peak. Additionally, LS-AMS turnaround times were minutes instead of days, and HPLC trace analyses required 1/6th the AMS instrument time required for analysis of graphite fractions by SS-AMS.

  10. Antioxidant activity guided separation of major polyphenols of marjoram (Origanum majorana L.) using flash chromatography and their identification by liquid chromatography coupled with electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Hossain, Mohammad B; Camphuis, Gabriel; Aguiló-Aguayo, Ingrid; Gangopadhyay, Nirupama; Rai, Dilip K

    2014-11-01

    Marjoram extracts have been separated into polar and nonpolar parts using liquid-liquid extraction. Both polar and nonpolar parts of the extracts were further fractionated by flash chromatography. The obtained fractions (90 polar and 45 nonpolar fractions) were investigated for their antioxidant activities by 2,2-diphenylpicrylhydrazyl and ferric ion reducing antioxidant power assays. A direct, positive, and linear relationship between antioxidant activity and total phenolic content of the fractions was observed. Based on antioxidant and total phenolic content data, the three fractions with the high antioxidant activities from polar and nonpolar part of the extract were analyzed for their constituent polyphenols by liquid chromatography coupled with electrospray ionization tandem mass spectrometry. Compounds were identified by matching the mass spectral data and retention time with those of authentic standards. Identification of the compounds for which there were no "in-house" standards available was carried out by accurate mass measurement of the precursor ions and product ions generated from collision-induced dissociation. Rosmarinic acid was found to be the strongest antioxidant polyphenol conferring the highest antioxidant activity to fractions 47 and 17 of polar and nonpolar part of the extract, respectively. The identification of the rosmarinic acid was further confirmed by (1) H NMR spectroscopy.

  11. Quantification of aroma compounds in Parmigiano Reggiano cheese by a dynamic headspace gas chromatography-mass spectrometry technique and calculation of odor activity value.

    Science.gov (United States)

    Qian, Michael; Reineccius, G A

    2003-03-01

    Potentially important aroma compounds in Parmigiano Reggiano cheese were quantified. Free fatty acids were isolated with ion-exchange chromatography and quantified by gas chromatography. Neutral aroma compounds were quantified with a purge-trap/gas chromatography-mass spectrometry with selective mass ion technique. Odor activity values were calculated based on sensory thresholds reported in literature. The calculated odor activity values suggest that 3-methylbutanal, 2-methylpropanal, 2-methylbutanal, dimethyl trisulfide, diacetyl, methional, phenylacetaldehyde, ethyl butanoate, ethyl hexanoate, ethyl octanoate, acetic, butanoic, hexanoic, and octanoic acids are the most important aroma contributors to Parmigiano Reggiano cheese.

  12. Alkaloid profiling of the Chinese herbal medicine Fuzi by combination of matrix-assisted laser desorption ionization mass spectrometry with liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Wang, J.; Heijden, R. van der; Spijksma, G.; Reijmers, T.; Wang, M.; Xu, G.; Hankemeier, T.; Greef, J. van der

    2009-01-01

    A matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) method was developed for the high throughput and robust qualitative profiling of alkaloids in Fuzi-the processed lateral roots of the Chinese herbal medicine Aconitum carmichaeli Debx (A. carmichaeli). After optimization, pow

  13. [Determination of pesticide residues from seed coating reagent in agricultural products using ultra performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Chen, Yue; Wang, Jinhua; Lu, Xiaoyu; Wang, Wanchun; Huang, Mei; Xu, Chaoyi

    2008-11-01

    An ultra performance liquid chromatography-tandem mass spectrometric method (UPLC-MS/MS) has been developed for the simultaneous determination of eight pesticide residues from seed coating in fruits, vegetable and grain. The sample was extracted by methanol-water (1:1, v/v) and determined by ultra performance liquid chromatography-electrospray ionization tandem mass spectrometry in positive mode (ESI+) and multiple reaction monitoring (MRM) mode. The UPLC analyses were performed on an Acquity UPLC C18 column with gradient eluation. The utility of the method was demonstrated by the analysis of crude extracts, with no sample clean up, from soybean. The linear range was 1 - 200 microg/L. The correlation coefficients (r) were under 0.997. The average recoveries of eight pesticides in samples (from 0.006 to 1.2 mg/kg) ranged from 60% to 110%, and the relative standard deviations (RSDs) were less than 10%. The results indicate that the method is easier, faster, more sensitive, and suitable for the qualitative and quantitative confirmation of pesticide residues from seed coating reagent in fruit, vegetable and grain samples.

  14. Quantitative determination of acetylcholine in microdialysis samples using liquid chromatography/atmospheric pressure spray ionization mass spectrometry.

    Science.gov (United States)

    Keski-Rahkonen, Pekka; Lehtonen, Marko; Ihalainen, Jouni; Sarajärvi, Timo; Auriola, Seppo

    2007-01-01

    A fast, simple and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the determination of acetylcholine in rat brain microdialysis samples. The chromatographic separation was achieved in 3 min on a reversed-phase column with isocratic conditions using a mobile phase containing 2% (v/v) of acetonitrile and 0.05% (v/v) of trifluoroacetic acid (TFA). A stable isotope-labeled internal standard was included in the analysis and detection was carried out with a linear ion trap mass spectrometer using selected reaction monitoring (SRM). Analyte ionization was performed with an atmospheric pressure chemical ionization (APCI) source without applying discharge current (atmospheric pressure spray ionization). This special ionization technique offered significant advantages over electrospray ionization for the analysis of acetylcholine with reversed-phase ion-pairing chromatography. The lower limit of quantification was 0.15 nM (1.5 fmol on-column) and linearity was maintained over the range of 0.15-73 nM, providing a concentration range that is significantly wider than that of the existing LC/MS methods. Good accuracy and precision were obtained for concentrations within the standard curve range. The method was validated and has been used extensively for the determination of acetylcholine in rat brain microdialysis samples.

  15. Determination of pesticides and veterinary drug residues in food by liquid chromatography-mass spectrometry: A review.

    Science.gov (United States)

    Masiá, Ana; Suarez-Varela, Maria Morales; Llopis-Gonzalez, Agustin; Picó, Yolanda

    2016-09-14

    Monitoring of pesticides and veterinary drug residues is required to enforce legislation and guarantee food safety. Liquid chromatography-mass spectrometry (LC-MS) is the prevailing technique for assessing both types of residues because LC offers a versatile and universal separation mechanism suitable for non-gas chromatography (GC) amenable and the majority of GC-amenable compounds. This characteristic becomes more relevant when LC is coupled to MS because the high sensitivity and specificity of the detector allows to apply generic sample preparation procedures, which simultaneously extract a wide variety of residues with different physico-chemical properties. Determination of metabolites and degradation products, non-target suspected screening of an increasing number of residues, and even unknowns identification are also becoming inherent LC-MS advantages thanks to the latest advances. For routine analysis and, in particular, for official surveillance purposes in food control, analytical methods properly validated following strict guidelines are needed. After a brief introduction and an outline of the legislation applicable around the world, aspects such as improvement of specificity of high-throughput methods, resolution and mass accuracy of identification strategies and quantitative accuracy are critically reviewed in this article. In them, extraction, separation and determination are emphasized. The main objective is to offer an assessment of the state of the art and identify research needs and future trends in determining pesticide and veterinary drug residues in food by LC-MS.

  16. Volatile constituents of Murraya koenigii fresh leaves using headspace solid phase microextraction--gas chromatography-mass spectrometry.

    Science.gov (United States)

    Sukkaew, Sayamol; Pripdeevech, Patcharee; Thongpoon, Chalermporn; Machan, Theeraphan; Wongchuphan, Rattana

    2014-12-01

    The volatile components of Murraya koenigii fresh leaves, collected from Surat Thani province, Thailand were studied by using headspace (HS) solid-phase microextraction (SPME) coupled with gas chromatography-mass spectrometry (GC-MS). The four fibers employed to extract the volatiles were polydimethylsiloxane (PDMS), polydimethylsiloxane-divinylbenzene (PDMS-DVB), carboxane-polydimethylsiloxane (CAR-PDMS) and polydimethylsiloxane-divinylbenzene-carboxane (PDMS-DVB-CAR). The volatile constituents of M. koenigii fresh leaves were also extracted by hydrodistillation and analyzed by GC-MS. Fifty-one compounds were identified by these fibers. Five major compounds, γ-terpinene, β-caryophyllene, β-phellandrene, a-selinene and a-pinene, were detected in all fibers. The PDMS-DVB-CAR fiber was considered as the best for trapping key volatiles of M. koenigii fresh leaves.

  17. Potato glycoalkaloids in soil-optimising liquid chromatography-time-of-flight mass spectrometry for quantitative studies.

    Science.gov (United States)

    Jensen, Pia H; Juhler, René K; Nielsen, Nikoline J; Hansen, Thomas H; Strobel, Bjarne W; Jacobsen, Ole S; Nielsen, John; Hansen, Hans Christian B

    2008-02-22

    Potato glycoalkaloids are produced in high amounts in potato fields during the growth season and losses to soil potentially impact shallow groundwater and via tiles to fresh water ecosystems. A quantitative liquid chromatography-electrospray ionization time-of-flight mass spectrometry (LC-ESI-TOF-MS) method for determination and quantification of potato glycoalkaloids and their metabolites in aqueous soil extracts was developed. The LC-ESI-TOF-MS method had linearities up to 2000microg/L for alpha-solanine and alpha-chaconine and up to 760microg/L for solanidine. No matrix effect was observed, and the detection limits found were in the range 2.2-4.7microg/L. The method enabled quantification of the potato glycoalkaloids in environmental samples.

  18. Advanced analytical techniques for the extraction and characterization of plant-derived essential oils by gas chromatography with mass spectrometry.

    Science.gov (United States)

    Waseem, Rabia; Low, Kah Hin

    2015-02-01

    In recent years, essential oils have received a growing interest because of the positive health effects of their novel characteristics such as antibacterial, antifungal, and antioxidant activities. For the extraction of plant-derived essential oils, there is the need of advanced analytical techniques and innovative methodologies. An exhaustive study of hydrodistillation, supercritical fluid extraction, ultrasound- and microwave-assisted extraction, solid-phase microextraction, pressurized liquid extraction, pressurized hot water extraction, liquid-liquid extraction, liquid-phase microextraction, matrix solid-phase dispersion, and gas chromatography (one- and two-dimensional) hyphenated with mass spectrometry for the extraction through various plant species and analysis of essential oils has been provided in this review. Essential oils are composed of mainly terpenes and terpenoids with low-molecular-weight aromatic and aliphatic constituents that are particularly important for public health.

  19. A metabonomic analysis of serum from rats treated with ricinine using ultra performance liquid chromatography coupled with mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Jing Peng

    Full Text Available A metabonomic approach based on ultra performance liquid chromatography coupled with mass spectrometry (UPLC/MS was used to study the hepatotoxicity of ricinine in rats. Potential biomarkers of ricinine toxicity and toxicological mechanism were analyzed by serum metabonomic method. The significant differences in the metabolic profiling of the control and treated rats were clear by using the principal components analysis (PCA of the chromatographic data. Significant changes of metabolite biomarkers like phenylalanine, tryptophan, cholic acid, LPC and PC were detected in the serum. These biochemical changes were related to the metabolic disorders in amino acids and phospholipids. This research indicates that UPLC/MS-based metabonomic analysis of serum samples can be used to predict the hepatotoxicity and further understand the toxicological mechanism induced by ricinine. This work shows that metabonomics method is a valuable tool in drug mechanism study.

  20. Determination of benzene in soft drinks and other beverages by isotope dilution headspace gas chromatography/mass spectrometry.

    Science.gov (United States)

    Cao, Xu-Liang; Casey, Valerie; Seaman, Steve; Tague, Brett; Becalski, Adam

    2007-01-01

    An automated, simple, and reproducible method was developed for the determination of benzene in soft drinks, based on isotope dilution headspace gas chromatography/mass spectrometry in the selected-ion monitoring mode. The method was used to assess benzene levels in samples of 124 soft drinks and beverages. Benzene was not detected in 60% of the 124 products. The average benzene levels in 6 products exceeded the Canadian maximum acceptable concentration of 5 microg/L for benzene in drinking water, and 2 of the 6 products had benzene levels above the World Health Organization guideline of 10 microg/L. The highest level of benzene, 23 microg/L, was found in a soft drink product specifically marketed to children.

  1. Analysis of volatile components in a Chinese fish sauce,Fuzhou Yulu, by gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Yuan-fan YANG; Shen-ru CHEN; Hui NI; Xing-qian YE

    2008-01-01

    Volatile components of Fuzhou Yulu, a Chinese fish sauce, were analyzed by gas chromatography-mass spectrometry (GC-MS), and two pretreatment methods, i.e., purge and trap (P&T) GC-MS and ethyl acetate extraction followed by GC-MS, were compared. P&T-GC-MS method determined 12 components, including sulfur-containing constituents (such as dimethyl disulfide), nitrogen-containing constituents (such as pyrazine derivatives), aldehydes and ketones. Ethyl ace tate extraction fol-lowed by GC-MS method detected 10 components, which were mainly volatile organic acids (such as benzenepropanoic acid) and esters. Neither of the two methods detected alcohols or trimethylamine. This study offers an important reference to determine volatile flavor components of traditional fish sauce through modem analysis methods.

  2. Amino acid δ13C analysis of hair proteins and bone collagen using liquid chromatography/isotope ratio mass spectrometry

    DEFF Research Database (Denmark)

    Raghavan, Maanasa; McCullagh, James S. O.; Lynnerup, Niels

    2010-01-01

    We report a novel method for the chromatographic separation and measurement of stable carbon isotope ratios (delta(13)C) of individual amino acids in hair proteins and bone collagen using the LC-IsoLink system, which interfaces liquid chromatography (LC) with isotope ratio mass spectrometry (IRMS......). This paper provides baseline separation of 15 and 13 of the 18 amino acids in bone collagen and hair proteins, respectively. We also describe an approach to analysing small hair samples for compound-specific analysis of segmental hair sections. The LC/IRMS method is applied in a historical context...... as a proxy for bone collagen at the amino acid level, this validates compound-specific isotope studies using hair as a model for palaeodietary reconstruction. Our results suggest that a small offset observed in the bulk delta(13)C values of the hair and bone samples may be attributed to two factors: (i...

  3. Determination of the volatile composition in brown millet, milled millet and millet bran by gas chromatography/mass spectrometry.

    Science.gov (United States)

    Liu, Jingke; Tang, Xia; Zhang, Yuzong; Zhao, Wei

    2012-02-24

    The volatile compounds from brown millet (BM), milled millet (MM) and millet bran (MB) were extracted using simultaneous distillation/extraction with a Likens-Nickerson apparatus. The extracts were analysed using gas chromatography coupled with mass spectrometry (GC-MS). A total of 65 volatile compounds were identified in all of the samples. Among these compounds, 51, 51 and 49 belonged to BM, MM and MB, respectively. Aldehydes and benzene derivatives were the most numerous among all of the compounds. Three compounds (hexanal, hexadecanoic acid and 2-methylnaphthalene) were dominant in the BM and MM materials. Eight compounds (hexanal, nonanal, (E)-2-nonenal, naphthalene, 2-methylnaphthalene, 1-methylnaphthalene, hexadecanoic acid and 2-pentylfuran) were dominant in the MB materials. Apart from the aromatic molecules, which were present in all fractions, compounds present only in BM, MM or MB were also identified.

  4. [Determination of chemical components of volatile oil from Cuminum cyminum L. by gas chromatography-mass spectrometry].

    Science.gov (United States)

    Yan, Jian-hui; Tang, Ke-wen; Zhong, Ming; Deng, Ning-hua

    2002-11-01

    Volatile oil was extracted from Cuminum cyminum L. by using steam distillation. More than sixty peaks were separated and 49 compounds were identified by gas chromatography-mass spectrometry (GC-MS). The relative amounts of the components were determined by area normalization method. Among the 49 compounds identified, there were 16 hydrocarbons and 32 oxygenated compounds. The main compnents were cuminal and safranal (accounting for 32.26% and 24.46% respectively in the components identified). The other nine compounds with contents all over 1%, were monterpenes, sesquiterpenes, aromatic aldehydes and aromatic oxides etc. The other components with relatively small amounts were chiefly terpenes, terpenols, terpenals, terpenones, terpene esters and aromatic compounds. It is good to separate polar and apolar components in the volatile oil from Cuminum cyminum L. on the GC capillary column of moderate polarity.

  5. Simultaneous determination of 24 constituents in Cortex Lycii using high-performance liquid chromatography-triple quadrupole mass spectrometry.

    Science.gov (United States)

    Zhang, Jing-Xian; Guan, Shu-Hong; Yang, Min; Feng, Rui-Hong; Wang, Yang; Zhang, Yi-Bei; Chen, Xin; Chen, Xiao-Hui; Bi, Kai-Shun; Guo, De-An

    2013-04-15

    A fast high-performance liquid chromatography (HPLC) coupled with electrospray ionization (ESI) tandem mass spectrometry method was developed to determine 24 components including 11 phenolic compounds, 9 phenolic amides, and 4 cyclic peptides in Cortex Lycii. The analytes were quantified by a triple quadrupole instrument in multiple reaction monitoring (MRM) mode. The fragmentation patterns of phenolic amides and cyclic peptides using ESI and collision-induced dissociation (CID) techniques are reported. This assay method was validated with respect to linearity (r(2)>0.9920), precision, repeatability, and accuracy (recovery rate between 93.0 and 105.9% with RSDPrinciple component analysis (PCA) was used to discriminate samples from different geographical regions of China, and cyclic peptides were considered to be the chemical markers responsible for the classification. The systematic and integrated assessment of Cortex Lycii provides sufficient evidence for the establishment of the quality standard.

  6. Effect of ginseng polysaccharide on the urinary excretion of type 2 diabetic rats studied by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Niu, Jun; Pi, Zifeng; Yue, Hao; Wang, Yang; Yu, Qing; Liu, Shuying

    2012-10-15

    Ginseng polysaccharide is known to have anti-hyperglycemic and anti-hyperlipidemic effects in vivo and its precise mechanism of action is not clear. A urinary metabolomics method based on rapid-resolution liquid chromatography/mass spectrometry (RRLC/MS) was developed to investigate the effect of water-soluble ginseng polysaccharide (WGP) on type 2 diabetes in rats. Principal component analysis (PCA) was carried out for pattern recognition and a clear separation between type 2 diabetic rats and those treated with WGP was achieved. Eight potential biomarkers were found and identified. Significantly increased inosine, serotonin, phenylpropionylglycine and dodecanedioic acid showed the effect of WGP on purine metabolism, tryptophan metabolism, fatty acid metabolism and energy metabolism. 1-Methyladenine, 4-deoxyerythronic acid, 5-hydroxyhexanoic acid and tetrahydrocortisol were significantly decreased which indicated that WGP can regulate DNA metabolism, organic acids metabolism and steroid hormone metabolism. This work is helpful in the effect mechanism study of ginseng polysaccharide.

  7. Feasibility of ultra-performance liquid chromatography-ion mobility-time-of-flight mass spectrometry in analyzing oxysterols.

    Science.gov (United States)

    Kylli, Petri; Hankemeier, Thomas; Kostiainen, Risto

    2017-03-03

    Oxysterols are oxygenated cholesterols that are important in many cell functions and they may also be indicative of certain diseases. The purpose of this work was to study the feasibility of ultra-performance liquid chromatography-ion mobility-time-of-flight mass spectrometry (UPLC-IM-TOFMS) using traveling wave cell in analyzing oxysterols and especially their isomers in biological samples. Oxysterols were analyzed as their p-toluenesulfonyl isocyanate derivatives, which improved the separation of isomeric oxysterols by ion mobility and ionization efficiency in the electrospray ionization step. The UPLC-IM-TOFMS method was shown to be fast and to provide good quantitative performance. The feasibility of the method was demonstrated in the analyses of oxysterols in fibroblast cell samples.

  8. Determination of seven bisphenol analogues in reed and Callitrichaceae by ultra performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lu, Libin; Yang, Yunjia; Zhang, Jing; Shao, Bing

    2014-03-15

    An analytical procedure was developed to simultaneously determine bisphenol S, bisphenol F, bisphenol B, bisphenol A, bisphenol AF, tetrachlorobisphenol A, and tetrabromobisphenol A in reed and Callitrichaceae. Homogenized samples were extracted with acetonitrile and purified using an ENVI™-Carb cartridge followed by an NH2 cartridge. The analytes were separated and quantified by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The recoveries at three fortified levels in reed and Callitrichaceae were 57-108% and 68-106%, respectively, with relative standard deviations of no more than 15% (n=6). The method limits of quantification and detection for the seven bisphenol analogues were 0.005-0.500μg/kg and 0.002-0.150μg/kg, respectively. This method was used to analyze the seven compounds in ten reed and Callitrichaceae samples collected from Zhejiang, China.

  9. Novel applications of high performance ion chromatography-inductively coupled plasma mass spectrometry (HPIC-ICP-MS)

    CERN Document Server

    Hann, S

    2001-01-01

    This work demonstrates the development of highly sensitive and selective analytical methods, which make use of the hyphenation of high performance ion chromatography (HPIC) to inductively coupled plasma sector field mass spectrometry (ICP-SFMS). On-line coupling a chromatographic separation method with an elemental detection method provides two advantages: (1) the components of a possibly interfering matrix can be separated allowing accurate and precise ultra trace analysis of the element of interest and (2) elemental species of an element can be separated and quantified. In this work, matrix separation methods for interference free determination of 232Th, 234U, 235U and 238U in geological matrices were developed and employed. Furthermore HPIC-ICP-SFMS was applied for ultra trace analysis of Pd in environmental and geological matrices. The usefulness of HPIC-ICP-SFMS for speciation studies was demonstrated by investigating the interaction of an anti-cancer drug (cisplatin) with guanosine monophosphates.

  10. Two-dimensional separation of ionic species by hyphenation of capillary ion chromatography × capillary electrophoresis-mass spectrometry.

    Science.gov (United States)

    Beutner, Andrea; Kochmann, Sven; Mark, Jonas Josef Peter; Matysik, Frank-Michael

    2015-03-17

    The separation of complex mixtures such as biological or environmental samples requires high peak capacities, which cannot be established with a single separation technique. Therefore, multidimensional systems are in demand. In this work, we present the hyphenation of the two most important (orthogonal) techniques in ion analysis, namely, ion chromatography (IC) and capillary electrophoresis (CE), in combination with mass spectrometry. A modulator was developed ensuring a well-controlled coupling of IC and CE separations. Proof-of-concept measurements were performed using a model system consisting of nucleotides and cyclic nucleotides. The data are presented in a multidimensional contour plot. Analyte stacking in the CE separation could be exploited on the basis of the fact that the suppressed IC effluent is pure water.

  11. Capillary ion chromatography-mass spectrometry for simultaneous determination of glucosylglycerol and sucrose in intracellular extracts of cyanobacteria.

    Science.gov (United States)

    Fa, Yun; Liang, Wenhui; Cui, He; Duan, Yangkai; Yang, Menglong; Gao, Jun; Liu, Huizhou

    2015-09-15

    A capillary ion chromatography-mass spectrometry (MS) method was proposed to determine glucosylglycerol (GG), sucrose, and five other carbohydrates. MS conditions and make-up flow parameters were optimized. This method is accurate and sensitive for simultaneous analysis of carbohydrates, with mean correlation coefficients of determination greater than 0.99, relative standard deviation of 0.91-2.81% for eight replicates, and average spiked recoveries of 97.3-104.9%. Limits of detection of sodium adduct were obtained with MS detection in selected ion mode for GG (0.006mg/L), sucrose (0.02mg/L), and other carbohydrates (0.03mg/L). This method was successfully applied to determine GG and sucrose in intracellular extracts of salt-stressed cyanobacteria.

  12. Solid-phase microcolumn extraction and gas chromatography-mass spectrometry identification of volatile organic compounds emitted by paper.

    Science.gov (United States)

    Hrivnák, Ján; Tölgyessy, Peter; Figedyová, Sona; Katuscák, Svetozár

    2009-11-15

    A rapid non-destructive sampling technique for the analysis of volatile organic compounds (VOCs) emitted by paper sheets is described. A capillary, which is connected to a microcolumn packed with Tenax TA, is inserted between two sheets at the centre of a paper stack encapsulated inside a PET/Al/PE composite foil. The other end of the microcolumn is connected to a gas-tight syringe and an appropriate volume of gaseous phase is aspirated. The microcolumn is then thermally desorbed in a modified GC inlet (modification is presented) and analysed by gas chromatography-mass spectrometry (GC-MS). In the chromatogram from the analysis of artificially aged paper sample 21 compounds were identified. Advantages of the method including the short sampling time (1 min), simplicity and economic aspect are discussed.

  13. Analysis of Indole Alkaloids from Rhazya stricta Hairy Roots by Ultra-Performance Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Akhgari, Amir; Laakso, Into; Seppänen-Laakso, Tuulikki; Yrjönen, Teijo; Vuorela, Heikki; Oksman-Caldentey, Kirsi-Marja; Rischer, Heiko

    2015-12-17

    Rhazya stricta Decne. (Apocynaceae) contains a large number of terpenoid indole alkaloids (TIAs). This study focused on the composition of alkaloids obtained from transformed hairy root cultures of R. stricta employing ultra-performance liquid chromatography-mass spectrometry (UPLC-MS). In the UPLC-MS analyses, a total of 20 TIAs were identified from crude extracts. Eburenine and vincanine were the main alkaloids followed by polar glucoalkaloids, strictosidine lactam and strictosidine. Secodine-type alkaloids, tetrahydrosecodinol, tetrahydro- and dihydrosecodine were detected too. The occurrence of tetrahydrosecodinol was confirmed for the first time for R. stricta. Furthermore, two isomers of yohimbine, serpentine and vallesiachotamine were identified. The study shows that a characteristic pattern of biosynthetically related TIAs can be monitored in Rhazya hairy root crude extract by this chromatographic method.

  14. Headspace solvent microextraction-gas chromatography-mass spectrometry for the analysis of volatile compounds from Foeniculum vulgare Mill.

    Science.gov (United States)

    Fang, Lianghua; Qi, Meiling; Li, Ting; Shao, Qinglong; Fu, Ruonong

    2006-06-07

    A novel and rapid headspace solvent microextraction followed by gas chromatography-mass spectrometry (HSME-GC-MS) for the analysis of the volatile compounds of Foeniculum vulgare Mill is described. HSME parameters including extracting solvent, extraction temperature and time, headspace volume and particle size were optimized. As a result, benzyl alcohol was finally used for the extraction at 70 degrees C for 20 min with headspace volume of 12.1 ml and particle size of 120 mesh. Under the determined conditions, the powered samples of Foeniculum vulgare Mill were directly applied for the analysis. A comparison of HSME-GC-MS, solid phase microextraction (SPME)-GC-MS and steam distillation (SD)-GC-MS methods was made and showed that the HSME-GC-MS method was simple, inexpensive and effective and can be used for the analysis of volatile compounds in traditional Chinese medicines (TCMs).

  15. Rapid determination of vitamin D₃ in milk-based infant formulas by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kwak, Byung-Man; Jeong, In-Seek; Lee, Moon-Seok; Ahn, Jang-Hyuk; Park, Jong-Su

    2014-12-15

    A rapid and simple sample preparation method for vitamin D3 (cholecalciferol) was developed for emulsified dairy products such as milk-based infant formulas. A sample was mixed in a 50 mL centrifuge tube with the same amount of water and isopropyl alcohol to achieve chemical extraction. Ammonium sulfate was used to induce phase separation. No-heating saponification was performed in the sample tube by adding KOH, NaCl, and NH3. Vitamin D3 was then separated and quantified using liquid chromatography-tandem mass spectrometry. The results for added recovery tests were in the range 93.11-110.65%, with relative standard deviations between 2.66% and 2.93%. The results, compared to those obtained using a certified reference material (SRM 1849a), were within the range of the certificated values. This method could be implemented in many laboratories that require time and labour saving.

  16. Determination of salbutamol and salbutamol glucuronide in human urine by means of liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Mareck, Ute; Guddat, Sven; Schwenke, Anne;

    2012-01-01

    The determination of salbutamol and its glucuronide in human urine following the inhalative and oral administration of therapeutic doses of salbutamol preparations was performed by means of direct urine injection utilizing liquid chromatography-tandem mass spectrometry (LC-MS/MS) and employing d(3......)-salbutamol and d(3)-salbutamol glucuronide as internal standards. Unconjugated salbutamol was detected in all administration study urine samples. Salbutamol concentrations following inhalation were commonly (99%) below 1000 ng/ml whereas values after oral administration frequently (48%) exceeded...... this threshold. While salbutamol glucuronide was not detected in urine samples collected after inhalation of the drug, 26 out of 82 specimens obtained after oral application contained salbutamol glucuronide with a peak value of 63 ng/ml. The percentage of salbutamol glucuronide compared to unconjugated...

  17. Detection of lysergic acid diethylamide (LSD) in urine by gas chromatography-ion trap tandem mass spectrometry.

    Science.gov (United States)

    Sklerov, J H; Kalasinsky, K S; Ehorn, C A

    1999-10-01

    A confirmatory method for the detection and quantitation of lysergic acid diethylamide (LSD) is presented. The method employs gas chromatography-tandem mass spectrometry (GC-MS-MS) using an internal ionization ion trap detector for sensitive MS-MS-in-time measurements of LSD extracted from urine. Following a single-step solid-phase extraction of 5 mL of urine, underivatized LSD can be measured with limits of quantitation and detection of 80 and 20 pg/mL, respectively. Temperature-programmed on-column injections of urine extracts were linear over the concentration range 20-2000 pg/mL (r2 = 0.999). Intraday and interday coefficients of variation were LSD-positive samples in this laboratory. Comparisons with alternate GC-MS methods and extraction procedures are discussed.

  18. Gas Chromatography-Mass Spectrometry Analysis of Constituent Oil from Lingzhi or Reishi Medicinal Mushroom, Ganoderma lucidum (Agaricomycetes), from Nigeria.

    Science.gov (United States)

    Ohiri, Reginald Chibueze; Bassey, Essien Eka

    2016-01-01

    Gas chromatography-mass spectrometry analysis of constituent oil from dried Ganoderma lucidum was carried out. Fresh G. lucidum obtained from its natural environment was thoroughly washed with distilled water and air-dried for 2 weeks and the component oils were extracted and analyzed. Four predominant components identified were pentadecanoic acid, 14-methyl-ester (retention time [RT] = 19.752 minutes; percentage total = 25.489), 9,12-octadecadienoic acid (Z,Z)- (RT = 21.629 minutes and 21.663 minutes; percentage total = 25.054), n-hexadecanoic acid (RT = 20.153 minutes; percentage total = 24.275), and 9-octadecenoic acid (Z)-, methyl ester (RT = 21.297 minutes; percentage total = 13.027). The two minor oils identified were 9,12-octadecadienoic acid, methyl ester, (E,E)- and octadecanoic acid, methyl ester (RT = 21.246 minutes and 21.503 minutes; percentage total = 7.057 and 5.097, respectively).

  19. Direct detection of free fatty acids in edible oils using supercritical fluid chromatography coupled with mass spectrometry.

    Science.gov (United States)

    Qu, Shuping; Du, Zhenxia; Zhang, Yun

    2015-03-01

    Determination of free fatty acids (FFAs) in food products is of enormous interest mainly because they are related to the quality and authenticity of the oils. In this study, supercritical fluid chromatography (SFC), followed by an electrospray ionisation triple-quadrupole mass spectrometry (ESI-MS), is shown to provide a novel method for the separation and detection of FFAs in edible oils without any pretreatment. Eight FFAs were separated on a HSS C18 SB column with gradient elution within 3 min. Effects of different columns, modifiers and column temperature changes were evaluated. The results indicated the feasibility of this method for the high-throughput determination of individual FFAs with satisfactory correlation coefficients (R(2)>0.994) and good reproducibility of RSDoil were successfully distinguished into several categories, showing a potential application for the determination of oil quality or authenticity.

  20. Measurement uncertainty for the determination of amphetamines in urine by liquid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Franco de Oliveira, Sarah Carobini Werner de Souza Eller; Yonamine, Mauricio

    2016-08-01

    A gas chromatography-mass spectrometry method for the determination of amphetamines in urine samples by means of liquid-phase microextraction was validated, including calculation of measurement uncertainty. After extraction in the three-phase mode, acceptor phase was withdrawn from the fiber and the residue was derivatized with trifluoroacetic anhydride. The method showed to be very simple, rapid and it required a significantly low amount of organic solvent for extraction. The limits of detection were 10 and 20μg/L for amphetamine and methamphetamine, respectively. The calibration curves were linear over the specified range (20μg/L to 1400μg/L; r(2)>0.99). The method showed to be both precise and accurate and a relative combined uncertainty of 2% was calculated. In order of importance, the factors which were more determinant for the calculation of method uncertainty were: analyte concentration, sample volume, trueness and method precision.

  1. Gas Chromatography-mass Spectrometry (GC-MS analysis of alkaloids isolated from Epipremnum aureum (Linden and Andre Bunting

    Directory of Open Access Journals (Sweden)

    Anju Meshram

    2015-02-01

    Full Text Available Recent advances in the use of GC coupled to MS have allowed a chemically guided isolation of uncommon and bioactive alkaloids. The present study was aimed to focus on the extraction and screening of alkaloids from Epipremnum aureum (Linden and Andre Bunting. It has been observed that the plant is very rich in alkaloids and the modified method employed for the extraction of alkaloid is efficient and selective, where the interference of other secondary metabolites is negligible. The identification of each compound was made through gas chromatography-mass spectrometry (GC-MS. A total of twenty six structurally different alkaloids were identified for the first time from this plant. E. aureum is highly rich in alkaloids and twenty six different alkaloids were characterized. The present study may help in the field of natural products’ chemistry and pharmaceuticals as well as drug discovery science and technology.

  2. Determination of trace mercury species by high performance liquid chromatography-inductively coupled plasma mass spectrometry after cloud point extraction.

    Science.gov (United States)

    Chen, Haiting; Chen, Jianguo; Jin, Xianzhong; Wei, Danyi

    2009-12-30

    A sensitive method for speciation analysis of inorganic mercury (Hg(2+)) and methyl mercury (MeHg(+)) has been developed by using high performance liquid chromatography (HPLC) combined with inductively coupled plasma mass spectrometry (ICP-MS) after cloud point extraction. The analytes were complexed with sodium diethyldithiocarbamate (DDTC) and preconcentrated by a non-ionic surfactant Triton X-114. Mercury species were effectively separated by HPLC in less than 6 min. The enhancement factors for 25 mL sample solution were 42 and 21, and the limits of detection were 4 and 10 ng L(-1) for Hg(2+) and MeHg(+), respectively. The developed method was successfully applied to the determination of trace amount of mercury species in environmental and biological samples.

  3. In vivo and in vitro metabolism of aspirin eugenol ester in dog by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Shen, Youming; Liu, Xiwang; Yang, Yajun; Li, Jianyong; Ma, Ning; Li, Bing

    2015-01-01

    Aspirin eugenol ester (AEE) is a promising drug candidate for treatment of inflammation, pain and fever and prevention of cardiovascular diseases with fewer side effects than its precursor, aspirin. Investigation into its metabolic process in target animal species will help to illustrate its mechanism of action and to establish its residual mark compound to formulate its dosage. Six beagle dogs were orally given a dose of 20 mg kg(-1) of AEE and one dog was used to prepare blank liver microsomes. Their liver microsomes were prepared for in vitro study and their plasma and urine were collected for in vivo metabolic analysis using liquid chromatography tandem mass spectrometry. In this study we identified 10 metabolites, M1, M2, M3, M4, M5 in phase I and M6, M7, M8, M9, M10 in phase II. Based on the metabolites of AEE, the pathways of AEE metabolism in dog were demonstrated.

  4. The analysis of tire rubber traces collected after braking incidents using Pyrolysis-GasChromatography/Mass Spectrometry.

    Science.gov (United States)

    Sarkissian, Garry

    2007-09-01

    Automobile tire marks can routinely be found at the scenes of crime, particularly hit-and-run accidents and are left on road surfaces because of sudden braking or the wheels spinning. The tire marks are left due to the friction between the tire rubber and the solid road surface, and do not always demonstrate the tire tread pattern. However, the tire mark will contain traces of the tire. In this study, Pyrolysis Gas Chromatography/Mass Spectrometry was used to analyze 12 tires from different manufacturer's and their traces collected after braking incidents. Tire marks were left on a conglomerate road surface with sudden braking. The samples were pyrolysed without removal of contaminant in a micro-furnace type pyrolyser. Quantitative and qualitative analysis were performed on all the samples. All 12 samples were distinguished from each other. Each of the tire traces were identified as coming from there original source.

  5. Liquid chromatography-high-resolution mass spectrometry for pesticide residue analysis in fruit and vegetables: screening and quantitative studies.

    Science.gov (United States)

    Gómez-Ramos, M M; Ferrer, C; Malato, O; Agüera, A; Fernández-Alba, A R

    2013-04-26

    This work reviews the current state-of-the-art of liquid chromatography coupled to high-resolution mass spectrometry (LC-HRMS) techniques applied to the analysis of pesticides in fruit-based and vegetable-based matrices. Nowadays, simultaneous trace analysis of hundreds of pesticides from different classes is required, preferably in just one run. The most commonly used QqQ-MS technology presents certain limitations in its application in a cost and effective way when analyzing a large number of pesticides. Thus, this review includes HRMS technology as a reliable complementary alternative allowing the analysis of a wide range of pesticides in food. Its capabilities and limitations in identifying, confirming and quantifying pesticides are discussed. HRMS instruments can adequately address such issues; however, the main drawbacks are as a result of insufficient prior optimization of the operational parameters during non-target analysis in full-scan mode and due to software shortcomings.

  6. Determination of artificial sweeteners in beverages with green mobile phases and high temperature liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Ordoñez, Edgar Y; Rodil, Rosario; Quintana, José Benito; Cela, Rafael

    2015-02-15

    A new analytical procedure involving the use of water and a low percentage of ethanol combined to high temperature liquid chromatography-tandem mass spectrometry has been developed for the determination of nine high-intensity sweeteners in a variety of drink samples. The method permitted the analysis in 23min (including column reequilibration) and consuming only 0.85mL of a green organic solvent (ethanol). This methodology provided limits of detection (after 50-fold dilution) in the 0.05-10mg/L range, with recoveries (obtained from five different types of beverages) being in the 86-110% range and relative standard deviation values lower than 12%. Finally, the method was applied to 25 different samples purchased in Spain, where acesulfame and sucralose were the most frequently detected analytes (>50% of the samples) and cyclamate was found over the legislation limit set by the European Union in a sample and at the regulation boundary in three others.

  7. Modernization of Chinese herbal compound and the high performance liquid chromatography tandem mass spectrometry (HPLC-MS)

    Institute of Scientific and Technical Information of China (English)

    LI Wen-lan; SUN Zhi; DU Juan

    2008-01-01

    Chinese herbal compound is playing an important role on curing human diseases. And it has been a trend that Chinese herbal compound is being used all over the world in 21 century. However, our Chinese herbal compound is facing serious challenge for the lack of canonical system of quality criterion for Chinese herbal compound so it has been a urgent problem to set up the quality control standards and reveal therapeutic basis of Chinese herbal compound. In order to give full play to the advantages of Chinese herbal compound, modern scientific and technological is used to research of Chinese herbal compound, especially the high performance liquid chromatography tandem mass spectrometry(HPLC-MS), because it is high sensitive, rapid, and obtain more information. It is very necessary that HPLC-MS is uesed to elucidate the effective components of basic substances of Chinese Herbal Compound, and endow traditional Chinese medicine with modern scientific connotation.

  8. Quantitative analysis of [Dmt(1)]DALDA in ovine plasma by capillary liquid chromatography-nanospray ion-trap mass spectrometry.

    Science.gov (United States)

    Wan, Haibao; Umstot, Edward S; Szeto, Hazel H; Schiller, Peter W; Desiderio, Dominic M

    2004-04-15

    The synthetic opioid peptide analog Dmt-D-Arg-Phe-Lys-NH(2) ([Dmt(1)]DALDA; [Dmt= 2',6'-dimethyltyrosine) is a highly potent and selective mu opioid-receptor agonist. A very sensitive and robust capillary liquid chromatography/nanospray ion-trap (IT) mass spectrometry method has been developed to quantify [Dmt(1)]DALDA in ovine plasma, using deuterated [Dmt(1)]DALDA as the internal standard. The standard MS/MS spectra of d(0)- and d(5)-[Dmt(1)]DALDA were obtained, and the collision energy was experimentally optimized to 25%. The product ion [ M + 2H-NH(3)](2+) (m/z 312.2) was used to identify and to quantify the synthetic opioid peptide analog in ovine plasma samples. The MS/MS detection sensitivity for [Dmt(1)]DALDA was 625 amol. A calibration curve was constructed, and quantitative analysis was performed on a series of ovine plasma samples.

  9. Gas chromatography-mass spectrometry analysis of fatty acid profiles of Antarctic and non-Antarctic yeasts.

    Science.gov (United States)

    Bhuiyan, Mohammad; Tucker, David; Watson, Kenneth

    2014-08-01

    The fatty acid profiles of Antarctic (n = 7) and non-Antarctic yeasts (n = 7) grown at different temperatures were analysed by gas chromatography-mass spectrometry. The Antarctic yeasts were enriched in oleic 18:1 (20-60 %), linoleic 18:2 (20-50 %) and linolenic 18:3 (5-40 %) acids with lesser amounts of palmitic 16:0 (Antarctic yeasts (n = 4) were enriched in 18:1 (20-55 %, with R. mucilaginosa at 75-80 %) and 18:2 (10-40 %) with lesser amounts of 16:0 (Antarctic yeasts (enriched in 18:1 and 18:2) and the third to the Antarctic yeasts (enriched in 18:2 and 18:3).

  10. Identification of Phenylethanoid Glycosides in Plant Extract of Plantago asiatica L. by Liquid Chromatography-Electrospray Ionization Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    LI,Li; LIU,Chunming; LIU,Zhiqiang; TSAO,Rong; LIU,Shuying

    2009-01-01

    The present work describes a liquid chromatography-electrospray ionization mass spectrometry(LC-ESI-MS)method for rapid identification of phenylethanoid glycosides in plant extract from Plnmgo asiatica L.By using a binary mobile phase system consisting of 0.2% acetic acid and acetonitrile under gradient conditions,a good sepa-ration was achieved on a reversed-phase C18 column.The[M-H] ions,the molecular weights,and the fragmentions of phenvlethanoid glycosides were obtained in the negative ion mode using LC-ESI-MS.The identification of the phenylethanoid glycosides(peaks 1-3) in the extract of P. asiatica L.was based on matching their retention time.the detection of molecular ions.and the fragment ions obtained by collision-induced dissociation(CID)ex-periments with those of the authentic standards and data reported in the literature.

  11. The identification of synthetic organic pigments in modern paints and modern paintings using pyrolysis-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Russell, Joanna; Singer, Brian W; Perry, Justin J; Bacon, Anne

    2011-05-01

    A collection of more than 70 synthetic organic pigments were analysed using pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS). We report on the analysis of diketo-pyrrolo-pyrrole, isoindolinone and perylene pigments which are classes not previously reported as being analysed by this technique. We also report on a number of azo pigments (2-naphthol, naphthol AS, arylide, diarylide, benzimidazolone and disazo condensation pigments) and phthalocyanine pigments, the Py-GC-MS analysis of which has not been previously reported. The members of each class were found to fragment in a consistent way and the pyrolysis products are reported. The technique was successfully applied to the analysis of paints used by the artist Francis Bacon (1909-1992), to simultaneously identify synthetic organic pigments and synthetic binding media in two samples of paint taken from Bacon's studio and micro-samples taken from three of his paintings and one painting attributed to him.

  12. Application of Gas Chromatography-mass Spectrometry in Analyzing Pharmacokinetics and Distribution of Deltamethrin in Miniature Pig Tissues

    Institute of Scientific and Technical Information of China (English)

    ZHU Pan; FAN Sai; ZOU Jian Hong; MIAO Hong; LI Jing Guang; ZHANG Guo Wen; WU Yong Ning

    2014-01-01

    Objective To characterize the pharmacokinetics and distribution profiles of deltamethrin in miniature pig tissues by gas chromatography-mass spectrometry (GC-MS). Methods Pharmacokinetics and distribution of deltamethrin in blood and tissues of 30 miniature pigs were studied by GC-MS after oral administration of deltamethrin (5 mg/kg bw). Data were processed by 3P97 software. Results The serum deltamethrin level was significantly lower in tissues than in blood of miniature pigs. The AUC0-72 h, Cmax, of deltamethrin were 555.330±316.987 ng h/mL and 17.861±11.129 ng/mL, respectively. The Tmax, of deltamethrin was 6.004±3.131 h. Conclusion The metabolism of deltamethrin in miniature pigs is fit for a one-compartment model with a weighting function of 1/C2. Deltamethrin is rapidly hydrolyzed and accumulated in miniature pig tissues.

  13. Analysis of Indole Alkaloids from Rhazya stricta Hairy Roots by Ultra-Performance Liquid Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Amir Akhgari

    2015-12-01

    Full Text Available Rhazya stricta Decne. (Apocynaceae contains a large number of terpenoid indole alkaloids (TIAs. This study focused on the composition of alkaloids obtained from transformed hairy root cultures of R. stricta employing ultra-performance liquid chromatography-mass spectrometry (UPLC-MS. In the UPLC-MS analyses, a total of 20 TIAs were identified from crude extracts. Eburenine and vincanine were the main alkaloids followed by polar glucoalkaloids, strictosidine lactam and strictosidine. Secodine-type alkaloids, tetrahydrosecodinol, tetrahydro- and dihydrosecodine were detected too. The occurrence of tetrahydrosecodinol was confirmed for the first time for R. stricta. Furthermore, two isomers of yohimbine, serpentine and vallesiachotamine were identified. The study shows that a characteristic pattern of biosynthetically related TIAs can be monitored in Rhazya hairy root crude extract by this chromatographic method.

  14. Comparative analysis of different plant oils by high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

    Science.gov (United States)

    Jakab, Annamaria; Héberger, Károly; Forgács, Esther

    2002-11-01

    Different vegetable oil samples (almond, avocado, corngerm, grapeseed, linseed, olive, peanut, pumpkin seed, soybean, sunflower, walnut, wheatgerm) were analyzed using high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry. A gradient elution technique was applied using acetone-acetonitrile eluent systems on an ODS column (Purospher, RP-18e, 125 x 4 mm, 5 microm). Identification of triacylglycerols (TAGs) was based on the pseudomolecular ion [M+1]+ and the diacylglycerol fragments. The positional isomers of triacylglycerol were identified from the relative intensities of the [M-RCO2]+ fragments. Linear discriminant analysis (LDA) as a common multivariate mathematical-statistical calculation was successfully used to distinguish the oils based on their TAG composition. LDA showed that 97.6% of the samples were classified correctly.

  15. Novel liquid chromatography-mass spectrometry method for sensitive determination of the mustard allergen Sin a 1 in food.

    Science.gov (United States)

    Posada-Ayala, Maria; Alvarez-Llamas, Gloria; Maroto, Aroa S; Maes, Xavier; Muñoz-Garcia, Esther; Villalba, Mayte; Rodríguez, Rosalía; Perez-Gordo, Marina; Vivanco, Fernando; Pastor-Vargas, Carlos; Cuesta-Herranz, Javier

    2015-09-15

    Mustard is a condiment added to a variety of foodstuffs and a frequent cause of food allergy. A new strategy for the detection of mustard allergen in food products is presented. The methodology is based on liquid chromatography analysis coupled to mass spectrometry. Mustard allergen Sin a 1 was purified from yellow mustard seeds. Sin a 1 was detected with a total of five peptides showing a linear response (lowest LOD was 5ng). Sin a 1 was detected in mustard sauces and salty biscuit (19±3mg/kg) where mustard content is not specified. Sin a 1, used as an internal standard, allowed quantification of this mustard allergen in foods. A novel LC/MS/MS SRM-based method has been developed to detect and quantify the presence of mustard. This method could help to detect mustard allergen Sin a 1 in processed foods and protect mustard-allergic consumers.

  16. The future of liquid chromatography-mass spectrometry in metabolic profiling and metabolomic studies for biomarker discovery.

    Energy Technology Data Exchange (ETDEWEB)

    Metz, Thomas O.; Zhang, Qibin; Page, Jason S.; Shen, Yufeng; Callister, Stephen J.; Jacobs, Jon M.; Smith, Richard D.

    2007-06-01

    The future utility of liquid chromatography-mass spectrometry (LC-MS) in metabolic profiling and metabolomic studies for biomarker discover will be discussed, beginning with a brief description of the evolution of metabolomics and the utilization of the three most popular analytical platforms in such studies: NMR, GC-MS, and LC-MS. Emphasis is placed on recent developments in high-efficiency LC separations and sensitive electrospray ionization approaches and the benefits to incorporating both in LC-MS-based approaches. The advantages and disadvantages of various quantitative approaches are reviewed, followed by the current LC-MS-based tools available for candidate biomarker characterization and identification. Finally, a brief prediction on the future path of LC-MS-based methods in metabolic profiling and metabolomic studies is given.

  17. Quantitative determination of five ergot alkaloids in rye flour by liquid chromatography-electrospray ionisation tandem mass spectrometry.

    Science.gov (United States)

    Mohamed, Rayane; Gremaud, Eric; Richoz-Payot, Janique; Tabet, Jean-Claude; Guy, Philippe A

    2006-05-05

    A confirmatory method for detecting five ergot alkaloids, ergocristine, ergotamine, ergonovine, ergocornine and alpha-ergokryptine, in rye flour is described using high performance liquid chromatography coupled to tandem mass spectrometry detection by monitoring two transition reactions per analyte. The procedure entails a liquid-liquid extraction followed by a clean-up step using a C18 solid-phase extraction (SPE) cartridge. An analogue compound, methysergide hydrogen maleinate, was used to assess both repeatability sample preparation and potential MS response fluctuations. The method was fully validated according to the European Union (EU) criteria. Detection and quantification limits of all analytes were calculated ranging from 7 to 11 microg/kg and from 23 to 37 microg/kg, respectively. Fifteen rye flour samples were investigated with the newly developed method, and none of them were above the current Swiss limits of 200mg/kg for total ergot alkaloids.

  18. Urinary metabonomics of stomach cancer assessed by rapid resolution liquid chromatography/time-of-flight mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    ZHANG Yan; REN Hui; JIANG Yang; GAO Yu-fei; LIU Shu-ying

    2013-01-01

    Background Stomach cancer is among the most commonly occurring malignancies worldwide.It would be beneficial to develop a urine-based assay whereby patients with undiagnosed stomach cancer could be screened and their cancer detected in the earliest stages.Methods A urinary metabonomics method based on ultra-performance liquid chromatography combined with quadruple time-of-flight mass spectrometry was used to analyze urine samples from patients with stomach cancer and healthy controls.Results Statistical analysis revealed a clear separation of patients and healthy controls using the aforementioned methodology.Some significantly changed metabolites were identified.Conclusions Use of the metabonomics method in patients with stomach cancer could effectively detect distinct changes in urinary metabolites and had the capacity to detect cancer; therefore,it may be a valuable tool in earlier diagnosis.Furthermore,the detection and identification of altered metabolites in the current study may help elucidate possible mechanisms involved in stomach cancer.

  19. Tequila volatile characterization and ethyl ester determination by solid phase microextraction gas chromatography/mass spectrometry analysis.

    Science.gov (United States)

    Vallejo-Cordoba, Belinda; González-Córdova, Aarón Fernando; del Carmen Estrada-Montoya, María

    2004-09-08

    Solid phase microextraction (SPME) and gas chromatography were used for tequila volatile characterization and ethyl ester quantitation. Several factors determined the differences in tequila volatile profiles obtained by the SPME technique, namely, sampling mode, fiber coating, and fiber exposure time. Each of these factors determined the most suitable conditions for the analysis of volatile profiles in tequila. Volatile extraction consisted of placing 40 mL of tequila in a sealed vial kept at 40 degrees C. A poly(dimethylsiloxane) fiber was immersed in the liquid for 60 min and desorbed for 5 min into the gas chromatograph. The identified volatiles by mass spectrometry were mainly alcohols, esters, and ketones. The calibration curves for ethyl hexanoate, octanoate, and decanoate followed linear relationships with highly significant (p tequila samples. Quantitative differences in ethyl esters were found for the four most commonly known tequila types: silver, gold, aged, and extra-aged.

  20. Determination of cocaine and benzoylecgonine in nails by liquid chromatography-electrospray ionization-tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Marzena Sykutera

    2015-02-01

    Full Text Available Nails and hair are a biological matrix which can be analyzed to confirm the use of a xenobiotic even several months after intake. Results of nail analysis can be used, for example, as evidence in civil and criminal law cases in which a history of drug use can influence the court’s decision. The paper presents results of analysis of a nail sample taken from a man who was suspected of trafficking cocaine. The suspect pleaded guilty to the possession of the drug for his own use because, as he claimed, he was addicted to cocaine. A nail sample was taken. Detection and quantification were carried out using liquid chromatography-mass spectrometry (LC-ESI-MS. The concentration of cocaine in nails was found to be 47 ng/mg, and benzoylecgonine – 14 ng/mg.