WorldWideScience

Sample records for chromatography mass spectrometry

  1. Pyrolysis - gas chromatography - mass spectrometry of lignins

    Energy Technology Data Exchange (ETDEWEB)

    Martin, F.; Saiz-Jimenez, C.; Gonzalez-Vila, F.J.

    1979-01-01

    Milled wood lignins from spruce, beech and bamboo were pyrolysed. The high-boiling products of pyrolysis were studied by GLC and mass spectrometry. The forty-three products identified provide information on the structural units of lignin.

  2. Radiogas chromatography mass spectrometry in the selected ion monitoring mode

    International Nuclear Information System (INIS)

    The value of selected ion monitoring in analyzing biological radio isotope incorporation experiments by radiogas chromatography mass spectrometry is illustrated with reference to the biosynthesis of the mycotoxin mycophenolic acid in Penicillium brevicompactum and the mode of action of the anticholesterolemic drug 20,25-diazacholesterol. Both examples used 1-[14C]acetate precursors. It is shown that the increased sensitivity and specificity of the selected ion monitoring mode detector permits straightforward detection and identification of the relatively small cellular pools associated with metabolic intermediates. The computer program RADSIM is described. Problems that still exist in using radiogas gas chromatography mass spectrometry technology to analyse isotope incorporation experiments are discussed. (author)

  3. Gas chromatography mass spectrometry : key technology in metabolomics

    NARCIS (Netherlands)

    Koek, Maud Marijtje

    2009-01-01

    Metabolomics involves the unbiased quantitative and qualitative analysis of the complete set of metabolites present in cells, body fluids and tissues. Gas chromatography coupled to mass spectrometry (GC-MS) is very suitable for metabolomics analysis, as it combines high separation power with sensiti

  4. Characterisation of cholera toxin by liquid chromatography - Electrospray mass spectrometry

    NARCIS (Netherlands)

    Baar, B.L.M. van; Hulst, A.G.; Wils, E.R.J.

    1999-01-01

    Cholera toxin, one of the toxins that may be generated by various strains of the bacterium Vibrio cholerae, can be considered as a substance possibly used in biological warfare. The possibilities of characterising the toxin by liquid chromatography electrospray mass spectrometry (LC-ES-MS) were inve

  5. High-Performance Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Vestal, Marvin L.

    1984-01-01

    Reviews techniques for online coupling of high-performance liquid chromatography with mass spectrometry, emphasizing those suitable for application to nonvolatile samples. Also summarizes the present status, strengths, and weaknesses of various techniques and discusses potential applications of recently developed techniques for combined liquid…

  6. Analysis of essential oils by gas chromatography and mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Masada, Y.

    1976-01-01

    The book is in two parts: first part Essential Oil includes compositae; labiatae; verbenaceae; oleaceae; umbelliferae; myrtaceae; euphorbiaceae; rutaceae; geraniaceae; rosaceae; lauraceae; myristicaceae; anonaceae; santalaceae; moraceae; piperaceae; zingiberaceae; araceae; gramineae; and cupressaceae written in English and Japanese. Part two includes essential oil; gas chromatography, and mass spectrometry written in Japanese. (DP)

  7. Specialized Gas Chromatography--Mass Spectrometry Systems for Clinical Chemistry.

    Science.gov (United States)

    Gochman, Nathan; And Others

    1979-01-01

    A discussion of the basic design and characteristics of gas chromatography-mass spectrometry systems used in clinical chemistry. A comparison of three specific systems: the Vitek Olfax IIA, Hewlett-Packard HP5992, and Du Pont DP-102 are included. (BB)

  8. Diesel characterization by high-resolution mass spectrometry - gas chromatography

    International Nuclear Information System (INIS)

    High-resolution mass spectrometry-gas chromatography is combined with the HC22 method in order to obtain detailed information about the chemical composition of diesel and the distribution of different compound types in terms of its final boiling temperature from a single analysis. The total time elapsed from sample injection and signal processing to obtain final results is 90 minutes. This fact makes this methodology a new and very important tool for the decision making process concerning the most suitable final boiling temperature and the type of treatment of the product in order to obtain diesel that fulfills the international standards. The consistency and repeatability of the experimental results are demonstrated

  9. Clinical applications of gas chromatography and gas chromatography-mass spectrometry of steroids

    NARCIS (Netherlands)

    Wolthers, BG; Kraan, GPB

    1999-01-01

    This review article underlines the importance of gas chromatography-mass spectrometry (GC-MS) for determination of steroids in man. The use of steroids labelled with stable isotopes as internal standard and subsequent analysis by GC-MS yields up to now the only reliable measurement of steroids in se

  10. Multidimensional chromatography coupled to mass spectrometry in analysing complex proteomics samples

    NARCIS (Netherlands)

    Horvatovich, Peter; Hoekman, Berend; Govorukhina, Natalia; Bischoff, Rainer

    2010-01-01

    Multidimensional chromatography coupled to mass spectrometry (LC(n)-MS) provides more separation power and an extended measured dynamic concentration range to analyse complex proteomics samples than one dimensional liquid chromatography coupled to mass spectrometry (1D-LC-MS). This review gives an o

  11. Identification of Unknown Contaminants in Water Samples from ISS Employing Liquid Chromatography/Mass Spectrometry/Mass Spectrometry

    Science.gov (United States)

    Rutz, Jeffrey A.; Schultz, John R.

    2008-01-01

    Mass Spectrometry/Mass Spectrometry (MS/MS) is a powerful technique for identifying unknown organic compounds. For non-volatile or thermally unstable unknowns dissolved in liquids, liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) is often the variety of MS/MS used for the identification. One type of LC/MS/MS that is rapidly becoming popular is time-of-flight (TOF) mass spectrometry. This technique is now in use at the Johnson Space Center for identification of unknown nonvolatile organics in water samples from the space program. An example of the successful identification of one unknown is reviewed in detail in this paper. The advantages of time-of-flight instrumentation are demonstrated through this example as well as the strategy employed in using time-of-flight data to identify unknowns.

  12. Analysis of radioactive mixed hazardous waste using derivatization gas chromatography/mass spectrometry, liquid chromatography, and liquid chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Six samples of core segments from Tank 101-SY were analyzed for chelators, chelator fragments, and several carboxylic acids by derivatization gas chromatography/mass spectrometry. The major components detected were ethylenediaminetetraacetic acid, nitroso-iminodiacetic acid, nitrilotriacetic acid, citric acid, succinic acid, and ethylenediaminetriacetic acid. The chelator of highest concentration was ethylenediaminetetraacetic acid in all six samples analyzed. Liquid chromatography was used to quantitate low molecular weight acids including oxalic, formic, glycolic, and acetic acids, which are present in the waste as acid salts. From 23 to 61% of the total organic carbon in the samples analyzed was accounted for by these acids

  13. Biomedical applications of gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Gas chromatography coupled with mass-spectrometry (GC/MS) is a modern technique, which has very important applications in the biomedical area. A large number of qualitative and quantitative determinations of drugs, amino acids, vitamins, lipids, aroma compounds, important nutrients, herb extracts were developed. The extraction procedure is the first important step in the analytical work. The internal standard is usually added at the very begin ing of the quantitative work. The best one is the stable isotopic labeled compound, usually the analogue of the compound of interest. Stable isotopic internal standard or compounds from the same chemical class having boiling point close to that of the compound of interest were used. Quantitation needs very well selected standards and method validation. Some validated methods for the determination of drugs and some active principles in biological media are presented. Several preconcentration extraction procedures were used. The quantitative determinations by detection (GC-MS) were performed. Good validation parameters were obtained: precision, accuracy, linearity in the range of interest, good limit of detection and quantitation, selectivity and specificity. Chromatography was performed on a 5% phenyl methyl polysiloxane column (15 or 30 m x 0.25 mm I.D., 0.25 μm film thickness) operated in suitable temperature programs. Helium carrier gas flow was 1ml/min. Ionization was performed by electron impact and detection in scan or selected ion monitoring (SIM) modes. The methods provided high response linearity (mean r = 0.99), precision and accuracy (< 10% C.V.). Applications of the quantitative methods in biomedical area are described. (author)

  14. Integrated liquid chromatography-heated nebulizer microchip for mass spectrometry.

    Science.gov (United States)

    Haapala, Markus; Saarela, Ville; Pól, Jaroslav; Kolari, Kai; Kotiaho, Tapio; Franssila, Sami; Kostiainen, Risto

    2010-03-10

    A new integrated microchip for liquid chromatography-mass spectrometry (LC-MS) is presented. The chip is made from bonded silicon and glass wafers with structures for a packed LC column channel, a micropillar frit, a channel for optional optical detection, and a heated vaporizer section etched in silicon and platinum heater elements on the glass cover. LC eluent is vaporized and mixed with nebulizer gas in the vaporizer section and the vapor is sprayed out from the chip. Nonpolar and polar analytes can be efficiently ionized in the gas phase by atmospheric pressure photoionization (APPI) as demonstrated with polycyclic aromatic hydrocarbons (PAHs) and selective androgen receptor modulators (SARMs). This is not achievable with present LC-MS chips, since they are based on electrospray ionization, which is not able to ionize nonpolar compounds efficiently. The preliminary quantitative performance of the new chip was evaluated in terms of limit of detection (down to 5 ng mL(-1)), linearity (r>0.999), and repeatability of signal response (RSD=2.6-4.0%) and retention time (RSD=0.3-0.5%) using APPI for ionization and PAHs as standard compounds. Determination of fluorescent compounds is demonstrated by using laser-induced fluorescence (LIF) for detection in the optical detection channel before the vaporizer section. PMID:20171315

  15. Mass spectrometry.

    Science.gov (United States)

    Burlingame, A. L.; Johanson, G. A.

    1972-01-01

    Review of the current state of mass spectrometry, indicating its unique importance for advanced scientific research. Mass spectrometry applications in computer techniques, gas chromatography, ion cyclotron resonance, molecular fragmentation and ionization, and isotope labeling are covered. Details are given on mass spectrometry applications in bio-organic chemistry and biomedical research. As the subjects of these applications are indicated alkaloids, carbohydrates, lipids, terpenes, quinones, nucleic acid components, peptides, antibiotics, and human and animal metabolisms. Particular attention is given to the mass spectra of organo-inorganic compounds, inorganic mass spectrometry, surface phenomena such as secondary ion and electron emission, and elemental and isotope analysis. Further topics include mass spectrometry in organic geochemistry, applications in geochronology and cosmochemistry, and organic mass spectrometry.

  16. The Use of Gas Chromatography and Mass Spectrometry to Introduce General Chemistry Students to Percent Mass and Atomic Mass Calculations

    Science.gov (United States)

    Pfennig, Brian W.; Schaefer, Amy K.

    2011-01-01

    A general chemistry laboratory experiment is described that introduces students to instrumental analysis using gas chromatography-mass spectrometry (GC-MS), while simultaneously reinforcing the concepts of mass percent and the calculation of atomic mass. Working in small groups, students use the GC to separate and quantify the percent composition…

  17. Simultaneous determination of seven gestagens in kidney fats by Ultra Performance Convergence Chromatography tandem mass spectrometry

    NARCIS (Netherlands)

    Tao, Yanfei; Balzer-Rutgers, Paula; Stolker, A.A.M.; Chen, Dongmei; Yuan, Zonghui

    2015-01-01

    An ultra-performance convergence chromatography (UPC2) system coupled tandem mass spectrometry was successfully utilised to analyse chlormadinone acetate, delmadinone acetate, fluorogestone acetate, medroxyprogesterone acetate, megestrol acetate, melengestrol acetate, chlortestasterone acetate in

  18. Chemical Composition of Latent Fingerprints by Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    Hartzell-Baguley, Brittany; Hipp, Rachael E.; Morgan, Neal R.; Morgan, Stephen L.

    2007-01-01

    An experiment in which gas chromatography-mass spectrometry (GC-MS) is used for latent fingerprint extraction and analysis on glass beads or glass slides is conducted. The results determine that the fingerprint residues are gender dependent.

  19. Uncovering biologically significant lipid isomers with liquid chromatography, ion mobility spectrometry and mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kyle, Jennifer E.; Zhang, Xing; Weitz, Karl K.; Monroe, Matthew E.; Ibrahim, Yehia M.; Moore, Ronald J.; Cha, Jeeyeon; Sun, Xiaofei; Lovelace, Erica S.; Wagoner, Jessica; Polyak, Stephen J.; Metz, Thomas O.; Dey, Sudhansu K.; Smith, Richard D.; Burnum-Johnson, Kristin E.; Baker, Erin S.

    2016-01-01

    Understanding how biological molecules are generated, metabolized and eliminated in living systems is important for interpreting processes such as immune response and disease pathology. While genomic and proteomic studies have provided vast amounts of information over the last several decades, interest in lipidomics has also grown due to improved analytical technologies revealing altered lipid metabolism in type 2 diabetes, cancer, and lipid storage disease. Liquid chromatography and mass spectrometry (LC-MS) measurements are currently the dominant approach for characterizing the lipidome by providing detailed information on the spatial and temporal composition of lipids. However, interpreting lipids’ biological roles is challenging due to the existence of numerous structural and stereoisomers (i.e. distinct acyl chain and double-bond positions), which are unresolvable using present LC-MS approaches. Here we show that combining structurally-based ion mobility spectrometry (IMS) with LC-MS measurements distinguishes lipid isomers and allows insight into biological and disease processes.

  20. Identification of Cyclopentenyl Fatty Acids by Gas Liquid Chromatography and Mass Spectrometry

    DEFF Research Database (Denmark)

    Shukla, V. K. S.; Abdel-Moety, E. M.; Larsen, Elfinn;

    1979-01-01

    The straight chain fatty acids and the cyclopentenyl fatty acids present in the lipids of Hydnocarpus wightiana seeds were separated as their pyrrolidides by means of gas chromatography. A gas chromatography-mass spectrometry system confirmed the complete separation and permitted the identification...

  1. Arsenic speciation by liquid chromatography coupled with ionspray tandem mass spectrometry

    DEFF Research Database (Denmark)

    Corr, J. J.; Larsen, Erik Huusfeldt

    1996-01-01

    Ionspray mass spectrometry, a well established organic analysis technique, has been coupled to high-performance liquid chromatography for speciation of organic arsenic compounds, The ionspray source and differentially pumped interface of the mass spectrometer were operated in dual modes...... fragmentation patterns showing molecular dissociation through an expected common product ion were obtained for the four arsenosugars, Molecular mode detection was utilized for qualitative verification of speciation analysis by high-performance liquid chromatography coupled to inductively coupled plasma mass...

  2. Liquid chromatography-thermospray mass spectrometry of DNA adducts formed with mitomycin C, porfiromycin and thiotepa.

    Science.gov (United States)

    Musser, S M; Pan, S S; Callery, P S

    1989-07-14

    High-performance liquid chromatography (HPLC) and thermospray mass spectrometry were combined for the analysis of DNA adducts formed from the interaction of the anticancer drugs mitomycin C, porfiromycin and thiotepa with calf thymus DNA. The adducts formed from reaction of mitomycin C and porfiromycin with DNA were separated from unmodified nucleosides by HPLC on a C18 column and identified by thermospray mass spectrometry. Thiotepa DNA adducts readily depurinated from DNA and were chromatographed and identified by thermospray liquid chromatography-mass spectrometry as the modified bases without the ribose moiety attached. The utility of thermospray mass spectrometry for the identification of microgram quantities of nucleoside adducts and depurinated base adducts of these anticancer drugs was demonstrated. PMID:2504760

  3. The analysis of aqueous mixtures using liquid chromatography-electrospray mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, S.

    1999-02-12

    The focus of this dissertation is the use of chromatographic methods coupled with electrospray mass spectrometry (ES-MS) for the determination of both organic and inorganic compounds in aqueous solutions. The combination of liquid chromatography (LC) methods and ES-MS offers one of the foremost methods for determining compounds in complex aqueous solutions. In this work, LC-ES-MS methods are devised using ion exclusion chromatography, reversed phase chromatography, and ion exchange chromatography, as well as capillary electrophoresis (CE). For an aqueous sample, these LC-ES-MS and CE-ES-MS techniques require no sample preparation or analyte derivatization, which makes it possible to observe a wide variety of analytes as they exist in solution. The majority of this work focuses on the use of LC-ES-MS for the determination of unknown products and intermediates formed during electrochemical incineration (ECI), an experimental waste remediation process. This report contains a general introduction to the project and the general conclusions. Four chapters have been removed for separate processing. Titles are: Chapter 2: Determination of small carboxylic acids by ion exclusion chromatography with electrospray mass spectrometry; Chapter 3: Electrochemical incineration of benzoquinone in aqueous media using a quaternary metal oxide electrode in the absence of a soluble supporting electrolyte; Chapter 4: The determination of electrochemical incineration products of 4-chlorophenol by liquid chromatography-electrospray mass spectrometry; and Chapter 5: Determination of small carboxylic acids by capillary electrophoresis with electrospray mass spectrometry.

  4. Liquid chromatography and liquid chromatography-mass spectrometry analysis of donepezil degradation products

    Directory of Open Access Journals (Sweden)

    Mladenović Aleksandar R.

    2015-01-01

    Full Text Available This study describes the investigation of degradation products of donepezil (DP using stability indicating RP-HPLC method for determination of donepezil, which is a centrally acting reversible acetylcholinesterase inhibitor. In order to investigate the stability of drug and formed degradation products, a forced degradation study of drug sample and finished product under different forced degradation conditions has been conducted. Donepezil hydrochloride and donepezil tablets were subjected to stress degradation conditions recommended by International Conference on Harmonization (ICH. Donepezil hydrochloride solutions were subjected to acid and alkali hydrolysis, chemical oxidation and thermal degradation. Significant degradation was observed under alkali hydrolysis and oxidative degradation conditions. Additional degradation products were observed under the conditions of oxidative degradation. The degradation products observed during forced degradation studies were monitored using the high performance liquid chromatography (HPLC method developed. The parent method was modified in order to obtain LC-MS compatible method which was used to identify the degradation products from forced degradation samples using high resolution mass spectrometry. The mass spectrum provided the precise mass from which derived molecular formula of drug substance and degradation products formed and proved the specificity of the method unambiguously. [Projekat Ministarstva nauke Republike Srbije, br. 172013

  5. Comparison of liquid chromatography-microchip/mass spectrometry to conventional liquid chromatography-mass spectrometry for the analysis of steroids.

    Science.gov (United States)

    Ahonen, Linda; Keski-Rahkonen, Pekka; Saarelainen, Taija; Paviala, Jenni; Ketola, Raimo A; Auriola, Seppo; Poutanen, Matti; Kostianen, Risto

    2012-04-01

    The feasibility of a microfluidic-based liquid chromatography-electrospray ionization/mass spectrometric system (HPLC-Chip/ESI/MS) was studied and compared to a conventional narrow-bore liquid chromatography-electrospray ionization/mass spectrometric (LC-ESI/MS) system for the analysis of steroids. The limits of detection (LODs) for oxime derivatized steroids, expressed as concentrations, were slightly higher with the HPLC-Chip/MS system (50-300 pM) using an injection volume of 0.5 μL than with the conventional LC-ESI/MS (10-150 pM) using an injection volume of 40 μL. However, when the LODs are expressed as injected amounts, the sensitivity of the HPLC-Chip/MS system was about 50 times higher than with the conventional LC-ESI/MS system. The results indicate that the use of HPLC-Chip/MS system is clearly advantageous only in the analysis of low-volume samples. Both methods showed good linearity and good quantitative and chromatographic repeatability. In addition to the instrument comparisons with oxime derivatized steroids, the feasibility of the HPLC-Chip/MS system in the analysis of non-derivatized and oxime derivatized steroids was compared. The HPLC-Chip/MS method developed for non-derivatized steroids was also applied to the quantitative analysis of 15 mouse plasma samples.

  6. Characterisation of the volatile profiles of infant formulas by proton transfer reaction-mass spectrometry and gas chromatography-mass spectrometry

    NARCIS (Netherlands)

    Ruth, van S.M.; Floris, V.; Fayoux, S.

    2006-01-01

    The volatile profiles of 13 infant formulas were evaluated by proton transfer reaction-mass spectrometry (PTR-MS) and gas chromatography¿mass spectrometry (GC¿MS). The infant formulas varied in brand (Aptamil, Cow & Gate, SMA), type (for different infant target groups) and physical form (powder/

  7. Different Ways to On-Line Hyphenate Centrifugal Partition Chromatography and Mass Spectrometry: Application to Prenylated Xanthones from Garcinia mangostana.

    Science.gov (United States)

    Destandau, Emilie; Michel, Thomas; Toribio, Alix; Elfakir, Claire

    2015-11-01

    Centrifugal partition chromatography is a liquid-liquid separation method well adapted for the fractionation or purification of natural compounds from plant extracts. However, following the preparative isolation, the fractions collected must be analysed by high-performance thin-layer chromatography or high-performance liquid chromatography to evaluate their composition and/or their purity. These additional steps are time-consuming and increase the risk of compound degradation. In order to get an instantaneous analysis of fraction content with structural information on the phytochemicals eluted, it is possible to hyphenate on-line centrifugal partition chromatography with mass spectrometry. Depending on the complexity of the extract, two different kinds of centrifugal partition chromatography-mass spectrometry coupling can be performed: centrifugal partition chromatography-mass spectrometry or centrifugal partition chromatography-high-performance liquid chromatography-mass spectrometry coupling. In the first case, one part of the centrifugal partition chromatography effluent is directly introduced in the mass spectrometry ionisation source to identify the eluted compounds, while in the second case, it is directed to a high-performance liquid chromatography-mass spectrometry system where compounds are first separated thanks to high-performance liquid chromatography and then identified using mass spectrometry.

  8. Different Ways to On-Line Hyphenate Centrifugal Partition Chromatography and Mass Spectrometry: Application to Prenylated Xanthones from Garcinia mangostana.

    Science.gov (United States)

    Destandau, Emilie; Michel, Thomas; Toribio, Alix; Elfakir, Claire

    2015-11-01

    Centrifugal partition chromatography is a liquid-liquid separation method well adapted for the fractionation or purification of natural compounds from plant extracts. However, following the preparative isolation, the fractions collected must be analysed by high-performance thin-layer chromatography or high-performance liquid chromatography to evaluate their composition and/or their purity. These additional steps are time-consuming and increase the risk of compound degradation. In order to get an instantaneous analysis of fraction content with structural information on the phytochemicals eluted, it is possible to hyphenate on-line centrifugal partition chromatography with mass spectrometry. Depending on the complexity of the extract, two different kinds of centrifugal partition chromatography-mass spectrometry coupling can be performed: centrifugal partition chromatography-mass spectrometry or centrifugal partition chromatography-high-performance liquid chromatography-mass spectrometry coupling. In the first case, one part of the centrifugal partition chromatography effluent is directly introduced in the mass spectrometry ionisation source to identify the eluted compounds, while in the second case, it is directed to a high-performance liquid chromatography-mass spectrometry system where compounds are first separated thanks to high-performance liquid chromatography and then identified using mass spectrometry. PMID:25615274

  9. Molecular mass ranges of coal tar pitch fractions by mass spectrometry and size-exclusion chromatography.

    Science.gov (United States)

    Karaca, F; Morgan, T J; George, A; Bull, I D; Herod, A A; Millan, M; Kandiyoti, R

    2009-07-01

    A coal tar pitch was fractionated by solvent solubility into heptane-solubles, heptane-insoluble/toluene-solubles (asphaltenes), and toluene-insolubles (preasphaltenes). The aim of the work was to compare the mass ranges of the different fractions by several different techniques. Thermogravimetric analysis, size-exclusion chromatography (SEC) and UV-fluorescence spectroscopy showed distinct differences between the three fractions in terms of volatility, molecular size ranges and the aromatic chromophore sizes present. The mass spectrometric methods used were gas chromatography/mass spectrometry (GC/MS), pyrolysis/GC/MS, electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS) and laser desorption time-of-flight mass spectrometry (LD-TOFMS). The first three techniques gave good mass spectra only for the heptane-soluble fraction. Only LDMS gave signals from the toluene-insolubles, indicating that the molecules were too involatile for GC and too complex to pyrolyze into small molecules during pyrolysis/GC/MS. ESI-FTICRMS gave no signal for toluene-insolubles probably because the fraction was insoluble in the methanol or acetonitrile, water and formic acid mixture used as solvent to the ESI source. LDMS was able to generate ions from each of the fractions. Fractionation of complex samples is necessary to separate smaller molecules to allow the use of higher laser fluences for the larger molecules and suppress the formation of ionized molecular clusters. The upper mass limit of the pitch was determined as between 5000 and 10,000 u. The pitch asphaltenes showed a peak of maximum intensity in the LDMS spectra at around m/z 400, in broad agreement with the estimate from SEC. The mass ranges of the toluene-insoluble fraction found by LDMS and SEC (400-10,000 u with maximum intensity around 2000 u by LDMS and 100-9320 u with maximum intensity around 740 u by SEC) are higher than those for the asphaltene fraction (200-4000 u with

  10. An improved method for measuring metaldehyde in surface water using liquid chromatography tandem mass spectrometry

    OpenAIRE

    Schumacher, Melanie; Castle, Glenn; Gravell, Anthony; Mills, Graham; Fones, Gary Roland

    2016-01-01

    The molluscicide metaldehyde (2,4,6,8-tetramethyl-1,3,5,7-tetraoxocanemetacetaldehyde) is an emerging pollutant. It is frequently detected in surface waters, often above the European Community Drinking Water Directive limit of 0.1 μg/L for a single pesticide. Gas chromatography mass spectrometry (GC–MS) can be used to determine metaldehyde in environmental waters, but this method requires time consuming extraction techniques prior to instrumental analysis. Use of liquid chromatography-tandem ...

  11. Identification of bound alcohols in soil humic acids by gas chromatography-mass spectrometry

    OpenAIRE

    Berthier, Gersende; Dou, Sen; Peakman, Torren; Lichtfouse, Eric

    2000-01-01

    International audience Humic acids are complex, partly macromolecular, yellow-brownish substances occurring in soils, waters and sediments. In order to shed some light on their molecular structure, crop humic acids were cleaved by alkaline hydrolysis (KOH). The products were fractionated by thin layer chromatography to give mono-alcohols which were analysed as acetate derivatives by gas chromatography coupled to mass spectrometry. Linear alcohols, sterols, stanols and plant-derived triterp...

  12. Characterization of Pentachlorophenol in Soil by Liquid Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    JIN Mi-cong; WANG Biao

    2004-01-01

    A simple, accurate and sensitive method for characterization of pentachlorophenol in soil was presented. The method included Soxhlet extraction using extracting agent of methanol/water/triethylamine (80∶20∶2), decontamination using solid-phase extraction (SPE) column and characterization by liquid chromatography-mass spectrometry (LCMS). The developed analytical method was successfully used to the determination of pentachlorophenol in soil samples.

  13. Simultaneous determination of seven flavonoids in Epimedium by liquid chromatography-tandem mass spectrometry method

    Institute of Scientific and Technical Information of China (English)

    Cai Sheng Wu; Bao Lin Guo; Yu Xin Sheng; Jin Lan Zhang

    2008-01-01

    In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoids, namely epimedin A, epimedin B, epimedin C, icariin, sagittatoside B, 2"-0-rhamnosyl icariside II, and baohuoside I in Epimedium from different sources.

  14. Analysis of glyphosate residues in cereals using liquid chromatography-mass spectrometry (LC-MS/MS)

    DEFF Research Database (Denmark)

    Granby, Kit; Johannesen, S.; Gabrielsen, Martin Vahl

    2003-01-01

    -up) in series with an ion chromatography column (separation) using NaHCO3 as eluent. A micro-membrane suppressor was inserted after the separator column to remove the Na + ions before detection by electrospray ionization mass spectrometry in the negative-ion mode. In MS/MS, mode the following transitions were...

  15. Determination of daminozide in apples and apple leaves by liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Mol, H.G.J.; Dam, R.C.J. van; Vreeken, R.J.; Steijger, O.M.

    1999-01-01

    A straightforward and efficient method was developed for the determination of intact daminozide in apples and apple leaves. After extraction with methanol and a clean-up step using a graphitized carbon cartridge, the extract was analysed by ion-trap liquid chromatography-tandem mass spectrometry (LC

  16. Simultaneous quantitative analysis of metabolites using ion-pair liquid chromatography-electrospray ionization mass spectrometry

    NARCIS (Netherlands)

    Coulier, L.; Bas, R.; Jespersen, S.; Verheij, E.; Werf, M.J. van der; Hankemeier, T.

    2006-01-01

    We have developed an analytical method, consisting of ion-pair liquid chromatography coupled to electrospray ionization mass spectrometry (IP-LC-ESI-MS), for the simultaneous quantitative analysis of several key classes of polar metabolites, like nucleotides, coenzyme A esters, sugar nucleotides, an

  17. Impurity profiling of trinitrotoluene using vacuum-outlet gas chromatography-mass spectrometry

    NARCIS (Netherlands)

    Brust, H.; Willemse, S.; Zeng, T.; Asten, A. van; Koeberg, M.; Heijden, A.E.D.M. van der; Bolck, A.; Schoenmakers, P.

    2014-01-01

    In this work, a reliable and robust vacuum-outlet gas chromatography-mass spectrometry (GC-MS) method is introduced for the identification and quantification of impurities in trinitrotoluene (TNT). Vacuum-outlet GC-MS allows for short analysis times the analysis of impurities in TNT was performed in

  18. Quantification and validation of ertapenem using a liquid chromatography-tandem mass spectrometry method

    NARCIS (Netherlands)

    van Rijn, S.P.; Wessels, A.M.A.; Greijdanus, B.; Touw, D.J.; Alffenaar, J.W.C.

    2014-01-01

    Ertapenem, a carbapenem, relies on time-dependent killing. Therapeutic drug monitoring (TDM) should be considered, when ertapenem is used in specific populations, to achieve optimal bactericidal activity and optimize drug-dosing regimens. No validated liquid chromatography-tandem mass spectrometry (

  19. Incorporation of Gas Chromatography-Mass Spectrometry into the Undergraduate Organic Chemistry Laboratory Curriculum

    Science.gov (United States)

    Giarikos, Dimitrios G.; Patel, Sagir; Lister, Andrew; Razeghifard, Reza

    2013-01-01

    Gas chromatography-mass spectrometry (GC-MS) is a powerful analytical tool for detection, identification, and quantification of many volatile organic compounds. However, many colleges and universities have not fully incorporated this technique into undergraduate teaching laboratories despite its wide application and ease of use in organic…

  20. Enrichment and characterization of phosphopeptides by immobilized metal affinity chromatography (IMAC) and mass spectrometry

    DEFF Research Database (Denmark)

    Thingholm, Tine E; Jensen, Ole N

    2009-01-01

    The combination of immobilized metal affinity chromatography (IMAC) and mass spectrometry is a widely used technique for enrichment and sequencing of phosphopeptides. In the IMAC method, negatively charged phosphate groups interact with positively charged metal ions (Fe3+, Ga3+, and Al3...

  1. Characterization of typical chemical background interferences in atmospheric pressure ionization liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Guo, Xinghua; Bruins, Andries P.; Covey, Thomas R.

    2006-01-01

    The structures and origins of typical chemical background noise ions in positive atmospheric pressure ionization liquid chromatography/mass spectrometry (API LC/MS) are investigated and summarized in this study. This was done by classifying chemical background ions using precursor and product ion sc

  2. Fully automated screening of veterinary drugs in milk by turbulent flow chromatography and tandem mass spectrometry

    NARCIS (Netherlands)

    Stolker, A.A.M.; Peters, R.J.B.; Zuiderent, R.; DiBussolo, J.M.; Martins, C.P.B.

    2010-01-01

    There is an increasing interest in screening methods for quick and sensitive analysis of various classes of veterinary drugs with limited sample pre-treatment. Turbulent flow chromatography in combination with tandem mass spectrometry has been applied for the first time as an efficient screening met

  3. Datura stramonium poisoning. Identification of tropane alkaloids in urine by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Nogué, S; Pujol, L; Sanz, P; de la Torre, R

    1995-01-01

    A case of acute poisoning by ingestion of Datura stramonium infusion is reported. The patient presented with a typical anticholinergic syndrome (dryness of mouth, mydriasis, flushing, tachycardia, agitation, hallucinations) and was treated with symptomatic and supportive measures. The presence of tropane belladona alkaloids in a urine sample was demonstrated by gas chromatography-mass spectrometry. PMID:7601297

  4. Coupling of electrokinetic chromatography and mass spectrometry for profiling of drugs

    NARCIS (Netherlands)

    Mol, R.

    2007-01-01

    In this thesis the potential of electrokinetic chromatography (EKC) – mass spectrometry (MS) has been evaluated, including its applicability to the impurity profiling of drugs. Over the past years, capillary zone electrophoresis (CZE) and EKC have gained acceptance as separation techniques next to l

  5. Identification of Synthetic Polymers and Copolymers by Analytical Pyrolysis-Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Kusch, Peter

    2014-01-01

    An experiment for the identification of synthetic polymers and copolymers by analytical pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) was developed and performed in the polymer analysis courses for third-year undergraduate students of chemistry with material sciences, and for first-year postgraduate students of polymer sciences. In…

  6. The bridge between thin layer chromatography-mass spectrometry and high-performance liquid chromatography-mass spectrometry: The realization of liquid thin layer chromatography-mass spectrometry (LTLC-MS).

    Science.gov (United States)

    Li, Yafeng; Wang, Jianing; Zhan, Lingpeng; Wleklinski, Michael; Wang, Jiyun; Xiong, Caiqiao; Liu, Huihui; Zhou, Yueming; Nie, Zongxiu

    2016-08-19

    The combination of thin layer chromatography (TLC) and mass spectrometry (MS) has been studied for decades, but for most cases MS detection is done after TLC separation is finished. Here, an online simultaneous TLC-MS analysis system, liquid thin layer chromatography-mass spectrometry (LTLC-MS), is developed which successfully synchronize TLC separation process and MS detection process like GC-MS and HPLC-MS do. And there's no need to use specially designed TLC, just regular TLC plates are enough. LTLC-MS method is composed of a newly developed ambient ionization method, glow discharge-matrix assisted infrared desorption ionization (GD-MAIRDI), and forced-flow TLC (FFTLC) technique, which guarantees the MS detection process does not disturb the TLC separation process throughout the whole analysis. The whole LTLC-MS analysis only need two steps and less than 15min. Mixtures as well as the two main components of a pain relief pills have been successfully analyzed by LTLC-MS. This proof of concept study opens up new possibilities of combining TLC with MS, and will further broaden the application abilities of TLC. PMID:27452991

  7. Screening for N-glycosylated proteins by liquid chromatography mass spectrometry

    DEFF Research Database (Denmark)

    Bunkenborg, Jakob; Pilch, Bartosz J; Podtelejnikov, Alexandre V;

    2004-01-01

    in complex mixtures by reducing sample complexity and enriching glycoprotein content. Glycosylated proteins are selected by an initial lectin chromatography step and digested with endoproteinase Lys-C. Glycosylated peptides are then selected from the digest mixture by a second lectin chromatography step....... The glycan components are removed with N-glycosidase F and the peptides digested with trypsin before analysis by on-line reversed-phase liquid chromatography mass spectrometry. Using two different lectins, concanavalin A and wheat germ agglutinin, this procedure was applied to human serum and a total of 86 N...

  8. Validation of a confirmatory method for the determination of melamine in egg by gas chromatography-mass spectrometry and ultra-performance liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    A sensitive and reliable method was developed and validated for detection and confirmation of melamine in egg based on gas chromatography-mass spectrometry (GC-MS) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Trichloroacetic acid solution was used for sample extraction and precipitation of proteins. The aqueous extracts were subjected to solid-phase extraction by mixed-mode reversed-phase/strong cation-exchange cartridges. Using ultra-performance liquid chromatography and electrospray ionization in the positive ion mode, melamine was determined by LC-MS/MS, which was completed in 5 min for each injection. For the GC-MS analysis, extracted melamine was derivatized with N,O-bis(trimethylsilyl)trifluoracetamide prior to selected ion monitoring detection in electron impact mode. The average recovery of melamine from fortified samples ranged from 85.2% to 103.2%, with coefficients of variation lower than 12%. The limit of detection obtained by GC-MS and UPLC-MS/MS was 10 and 5 μg kg-1, respectively. This validated method was successfully applied to the determination of melamine in real samples from market.

  9. Determination of capsaicin, dihydrocapsaicin, and nonivamide in self-defense weapons by liquid chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Reilly, C A; Crouc, D J; Yost, G S; Fatah, A A

    2001-04-01

    Sensitive and selective liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) methods for the analysis of capsaicin, dihydrocapsaicin, and nonivamide in pepper spray products have been developed. Chromatographic separation of the capsaicinoid analogues was achieved using a reversed-phase HPLC column and a stepwise gradient of methanol and distilled water containing 0.1% (v/v) formic acid. Identification and quantification of the capsaicinoids was achieved by electrospray ionization single-stage mass spectrometry monitoring the protonated molecules of the internal standard (m/z 280), capsaicin (m/z 306), dihydrocapsaicin (m/z 308), and nonivamide (m/z 294) or by tandem mass spectrometry monitoring the appropriate precursor-to-product-ion transitions. The plot of concentration versus peak area ratio was linear over the range of 10-750 ng/ml using LC-MS and 10-500 ng/ml using LC-MS-MS. However, to accurately quantify the capsaicinoids in the pepper spray products calibration curves between 10 and 1000 ng were constructed and fit using a weighted quadratic equation. Using the quadratic curve, the accuracy of the assay ranged from 91 to 102% for all analytes. The intra-assay precision (RSD) for capsaicin was 2% at 25 ng/ml, 10% at 500 ng/ml, and 3% at 800 ng/ml. The inter-assay precision (RSD) for capsaicin was 6% at 25 ng/ml, 6% at 500 ng/ml, and 9% at 800 ng/ml. Similar values for inter- and intra-assay precision were experimentally obtained for both dihydrocapsaicin and nonivamide. The analysis of selected pepper spray products demonstrated that the capsaicinoid concentration in the products ranged from 0.7 to 40.5 microg/microl. PMID:11330795

  10. Screening Non-colored Phenolics in Red Wines using Liquid Chromatography/Ultraviolet and Mass Spectrometry/Mass Spectrometry Libraries

    Directory of Open Access Journals (Sweden)

    Changqing Duan

    2007-03-01

    Full Text Available Liquid chromatography/ultraviolet (LC/UV and mass spectrometry/mass spectrometry (MS/MS libraries containing 39 phenolic compounds were established by coupling a LC and an ion trap MS with an electrospray ionization (ESI source, operated in negative ion mode. As a result, the deprotonated [M-H]- molecule was observed for all the analyzed compounds. Using MS/MS hydroxybenzoic acid and hydroxycinnamic acids showed a loss of CO2 and production of a [M-H-44] - fragment and as expected, the UV spectra of these two compounds were affected by their chemical structures. For flavonol and flavonol glycosides, the spectra of their glycosides and aglycones produced deprotonated [M-H]- and [A-H]- species, respectively, and their UV spectra each presented two major absorption peaks. The UV spectra and MS/MS data of flavan-3-ols and stilbenes were also investigated. Using the optimized LC/MS/MS analytical conditions, the phenolic extracts from six representative wine samples were analyzed and 31 phenolic compounds were detected, 26 of which were identified by searching the LC/UV and MS/MS libraries. Finally, the presence of phenolic compounds was confirmed in different wine samples using the LC/UV and LC/MS/MS libraries.

  11. Quantitative liquid chromatography/mass spectrometry/mass spectrometry warfarin assay for in vitro cytochrome P450 studies.

    Science.gov (United States)

    Zhang, Z Y; King, B M; Wong, Y N

    2001-11-01

    A sensitive assay using high-performance liquid chromatography tandem mass spectrometry (MS/MS) has been established for the quantitative analysis of cytochrome P450 form-specific activities using warfarin as a probe substrate. Four metabolites, 6-, 7-, 8-, and 10-hydroxywarfarin, were chromatographically resolved within 10 min using gradient mobile phases. The mass spectrometry was operated under negative ionization mode. The MS/MS product ion spectra of warfarin and the metabolites were generated using collision-activated dissociation and interpreted. The abundant product ions of the metabolites were selected for quantification applying multiple reaction monitoring. Quantification was based on a quadratic or power curve of the peak area ratio of the metabolite over the internal standard against the respective concentration of the metabolite. This assay has been validated from 2 to 1000 nM for 10-hydroxywarfarin and from 2 to 5000 nM for 6-, 7-, and 8-hydroxywarfarin and successfully applied to evaluate cytochrome P450-mediated drug-drug interactions in vitro using human hepatocytes and liver microsomal preparations. PMID:11673893

  12. Determination of Bedaquiline in Human Serum Using Liquid Chromatography-Tandem Mass Spectrometry

    OpenAIRE

    Alffenaar, Jan-Willem C; Bolhuis, Mathieu; van Hateren, Kai; Sturkenboom, Marieke; Akkerman, Onno; de Lange, Wiel; Greijdanus, Ben; van der Werf, Tjip; Touw, Daan

    2015-01-01

    Bedaquiline, a diarylquinoline for the treatment of multidrug-resistant tuberculosis (TB), relies on exposure-dependent killing. As data on drug exposure in specific populations are scarce, pharmacokinetic studies may be of interest. No simple and robust validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been reported to date. Therefore, a new method using a quadrupole mass spectrometer was developed for analysis of bedaquiline and N-monodesmethyl bedaquiline (M2) ...

  13. New Developments in Liquid Chromatography Mass Spectrometry for the Determination of Micropollutants

    Directory of Open Access Journals (Sweden)

    Zoraida Sosa-Ferrera

    2012-01-01

    Full Text Available The combination of liquid chromatography (LC with mass spectrometry (MS in the environmental field has appeared as a valuable tool for the determination of micropollutants. Several groups of compounds have been considered as particularly relevant (e.g., pharmaceuticals, hormones and other endocrine-disrupting, personal care products and their metabolites, flame retardants, surfactants, and plasticizers, among others since the same ones are continuously being released in the environment mainly as a result of the manufacturing processes, the disposal of unused or expired products, and the excreta. Because these micropollutants are not completely removed in the environment, very specific and sensitive analytical procedures are needed for their identification and quantification. High performance liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS (or LC-MS2 and especially time-of-flight mass spectrometry (TOF/MS, has allowed that many environmental contaminants that are highly polar or nonvolatile or have a high molecular weight to be analyzed or identified. In this work we present an overview focused on the developments of liquid chromatography mass spectrometry applied to the analysis of the main classes of micropollutants in aqueous and solid environmental samples. Various aspects of methodologies based on these techniques, including sample preparation (extraction/preconcentration and matrix effects, are discussed.

  14. Community air monitoring for pesticides-part 2: multiresidue determination of pesticides in air by gas chromatography, gas chromatography-mass spectrometry, and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Hengel, Matt; Lee, P

    2014-03-01

    Two multiresidue methods were developed to determine pesticides in air collected in California. Pesticides were trapped using XAD-4 resin and extracted with ethyl acetate. Based on an analytical method from the University of California Davis Trace Analytical Laboratory, pesticides were detected by analyzing the extract by gas chromatography-mass spectrometry (GC-MS) to determine chlorothalonil, chlorthal-dimethyl, cycloate, dicloran, dicofol, EPTC, ethalfluralin, iprodione, mefenoxam, metolachlor, PCNB, permethrin, pronamide, simazine, trifluralin, and vinclozolin. A GC with a flame photometric detector was used to determine chlorpyrifos, chlorpyrifos oxon, diazinon, diazinon oxon, dimethoate, dimethoate oxon, fonophos, fonophos oxon, malathion, malathion oxon, naled, and oxydemeton. Trapping efficiencies ranged from 78 to 92 % for low level (0.5 μg) and 37-104 % for high level (50 and 100 μg) recoveries. Little to no degradation of compounds occurred over 31 days; recoveries ranged from 78 to 113 %. In the California Department of Food and Agriculture (CDFA) method, pesticides were detected by analyzing the extract by GC-MS to determine chlorothalonil, chlorpyrifos, cypermethrin, dichlorvos, dicofol, endosulfan 1, endosulfan sulfate, oxyfluorfen, permethrin, propargite, and trifluralin. A liquid chromatograph coupled to a MS was used to determine azinphos-methyl, chloropyrifos oxon, DEF, diazinon, diazinon oxon, dimethoate, dimethoate oxon, diuron, EPTC, malathion, malathion oxon, metolachlor, molinate, norflurazon, oryzalin, phosmet, propanil, simazine and thiobencarb. Trapping efficiencies for compounds determined by the CDFA method ranged from 10 to 113, 22 to 114, and 56 to 132 % for 10, 5, and 2 μg spikes, respectively. Storage tests yielded 70-170 % recovery for up to 28 days. These multiresidue methods represent flexible, sensitive, accurate, and cost-effective ways to determine residues of various pesticides in ambient air. PMID:24370860

  15. Analysis of ganciclovir and its related substances using high performance liquid chromatography and liquid chromatography-mass spectrometry methods

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all r...

  16. Detection of Stimulants and Narcotics by Liquid Chromatography-Tandem Mass Spectrometry and Gas Chromatography-Mass Spectrometry for Sports Doping Control.

    Science.gov (United States)

    Ahrens, Brian D; Kucherova, Yulia; Butch, Anthony W

    2016-01-01

    Sports drug testing laboratories are required to detect several classes of compounds that are prohibited at all times, which include anabolic agents, peptide hormones, growth factors, beta-2 agonists, hormones and metabolic modulators, and diuretics/masking agents. Other classes of compounds such as stimulants, narcotics, cannabinoids, and glucocorticoids are also prohibited, but only when an athlete is in competition. A single class of compounds can contain a large number of prohibited substances and all of the compounds should be detected by the testing procedure. Since there are almost 70 stimulants on the prohibited list it can be a challenge to develop a single screening method that will optimally detect all the compounds. We describe a combined liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) testing method for detection of all the stimulants and narcotics on the World Anti-Doping Agency prohibited list. Urine for LC-MS/MS testing does not require sample pretreatment and is a direct dilute and shoot method. Urine samples for the GC-MS method require a liquid-liquid extraction followed by derivatization with trifluoroacetic anhydride.

  17. Quantitative Analysis of Tetramethylenedisulfotetramine ("Tetramine") Spiked into Beverages by Liquid Chromatography Tandem Mass Spectrometry with Validation by Gas Chromatography Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Owens, J; Hok, S; Alcaraz, A; Koester, C

    2008-11-13

    Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limit of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.

  18. Urinary metabonomics study in a rat model in response to protein-energy malnutrition by using gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Wu, Zeming; Li, Min; Zhao, Chunxia; Zhou, Jia; Chang, Yuwei; Li, Xiang; Gao, Peng; Lu, Xin; Li, Yousheng; Xu, Guowang

    2010-11-01

    Systematic studies were performed on the biological perturbations in metabolic phenotype responding to protein-energy malnutrition through global metabolic profiling analysis, in combination with pattern recognition. The malnutrition rat model was established through five weeks of strict diet restriction, and the metabonome data obtained from gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS) were integrated to approximate the comprehensive metabolic signature. Principal component analysis and orthogonal projection to latent structure analysis were used for the classification of metabolic phenotypes and discovery of differentiating metabolites. The perturbations in the urine profiles of malnourished rats were marked by higher levels of creatine, threitol, pyroglutamic acid, gluconic acid and kynurenic acid, as well as decreased levels of succinic acid, cis-aconitic acid, citric acid, isocitric acid, threonic acid, trimethylglycine, N-methylnicotinic acid and uric acid. The alterations in these metabolites were associated with perturbations in energy metabolism, carbohydrate, amino acid, and fatty acid metabolism, purine metabolism, cofactor and vitamin metabolism, in response to protein and energy malnutrition. Our findings show the integration of GC-MS and LC-MS techniques for untargeted metabolic profiling analysis was promising for nutriology. PMID:20717558

  19. Gas Chromatography/Atmospheric Pressure Chemical Ionization Tandem Mass Spectrometry for Fingerprinting the Macondo Oil Spill.

    Science.gov (United States)

    Lobodin, Vladislav V; Maksimova, Ekaterina V; Rodgers, Ryan P

    2016-07-01

    We report the first application of a new mass spectrometry technique (gas chromatography combined to atmospheric pressure chemical ionization tandem mass spectrometry, GC/APCI-MS/MS) for fingerprinting a crude oil and environmental samples from the largest accidental marine oil spill in history (the Macondo oil spill, the Gulf of Mexico, 2010). The fingerprinting of the oil spill is based on a trace analysis of petroleum biomarkers (steranes, diasteranes, and pentacyclic triterpanes) naturally occurring in crude oil. GC/APCI enables soft ionization of petroleum compounds that form abundant molecular ions without (or little) fragmentation. The ability to operate the instrument simultaneously in several tandem mass spectrometry (MS/MS) modes (e.g., full scan, product ion scan, reaction monitoring) significantly improves structural information content and sensitivity of analysis. For fingerprinting the oil spill, we constructed diagrams and conducted correlation studies that measure the similarity between environmental samples and enable us to differentiate the Macondo oil spill from other sources.

  20. DETERMINATION OF ACRYLAMIDE IN FOOD BY GAS AND LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY

    Directory of Open Access Journals (Sweden)

    Michaela Vieriková

    2010-07-01

    Full Text Available  Acrylamide in food was determined by gas chromatography - mass spectrometry (GC-MS after bromination of acrylamide and underivatized acrylamide was quantified by ultra performance liquid chromatography -mass spectrometry (UPLC-MS. Two different sample preparation methods were used and optimised. The GC-MS method was used for various food matrices like breads, potato crisps, potato crackers, french fries. The UPLC-MS method was used for analysis of coffee. The limit of detection and limit of quantification for acrylamide were 7 µg.kg-1 and 20 µg.kg-1 by GC-MS, 9 µg.kg-1  and 30 µg.kg-1 by UPLC-MS. For both methods the reproducibility, given as relative standard deviation was    doi:10.5219/61  

  1. Liquid Chromatography-Electrospray Tandem Mass Spectrometry of Terpenoid Lactones in Ginkgo biloba

    OpenAIRE

    Sun, Yongkai; Li, Wenkui; Fitzloff, John F.; van Breemen, Richard B

    2005-01-01

    Ginkgo biloba (ginkgo) is one of most frequently used botanical dietary supplements. The bioactive constituents include the terpenoid lactones consisting of bilobalide and the ginkgolides A, B, C, and J. A new assay based on high performance liquid chromatography-electrospray tandem mass spectrometry (LC-MS-MS) was developed for the measurement of the terpenoid lactones in ginkgo products such as leaf powder and extracts. Initially, the MS-MS fragmentation pathways of ginkgolides were investi...

  2. Direct Quantification of Cannabinoids and Cannabinoid Glucuronides in Whole Blood by Liquid Chromatography Tandem Mass Spectrometry

    OpenAIRE

    Schwope, David M.; Scheidweiler, Karl B.; Huestis, Marilyn A.

    2011-01-01

    The first method for quantifying cannabinoids and cannabinoid glucuronides in whole blood by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and validated. Solid-phase extraction followed protein precipitation with acetonitrile. HPLC separation was achieved in 16 min via gradient elution. Electrospray ionization was utilized for cannabinoid detection; both positive (Δ9-tetrahydrocannabinol [THC], cannabinol [CBN]) and negative (11-hydroxy-THC [11-OH-THC], 11-nor-9-carb...

  3. New Developments in Liquid Chromatography Mass Spectrometry for the Determination of Micropollutants

    OpenAIRE

    Zoraida Sosa-Ferrera; Cristina Mahugo-Santana; José Juan Santana-Rodríguez

    2012-01-01

    The combination of liquid chromatography (LC) with mass spectrometry (MS) in the environmental field has appeared as a valuable tool for the determination of micropollutants. Several groups of compounds have been considered as particularly relevant (e.g., pharmaceuticals, hormones and other endocrine-disrupting, personal care products and their metabolites, flame retardants, surfactants, and plasticizers, among others) since the same ones are continuously being released in the environment mai...

  4. The Application of Resonance-Enhanced Multiphoton Ionization Technique in Gas Chromatography Mass Spectrometry

    OpenAIRE

    2014-01-01

    Gas chromatography resonance-enhanced multiphoton ionization time-of-flight mass spectrometry (GC/REMPI-TOFMS) using a nanosecond laser has been applied to analyze the 16 polycyclic aromatic hydrocarbons (PAHs). The excited-state lifetime, absorption characters, and energy of electronic states of the 16 PAHs were investigated to optimize the ionization yield. A river water sample pretreated by means of solid phase extraction was analyzed to evaluate the performance of the analytical instrumen...

  5. A review of clinical diagnostic applications of liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Shushan, Bori

    2010-01-01

    Liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS) technology is emerging as a complementary method to traditional methodology used for clinical applications. Enhanced specificity and high-throughput capabilities are providing significant benefits to clinical diagnostic laboratories conducting routine analyses. This technology is expected to expand rapidly as scientists focus on more complicated challenges that can be solved efficiently by adding LC/MS/MS to their arsenal of techniques. PMID:20949635

  6. Review of in situ derivatization techniques for enhanced bioanalysis using liquid chromatography with mass spectrometry.

    Science.gov (United States)

    Baghdady, Yehia Z; Schug, Kevin A

    2016-01-01

    Accurate and specific analysis of target molecules in complex biological matrices remains a significant challenge, especially when ultra-trace detection limits are required. Liquid chromatography with mass spectrometry is often the method of choice for bioanalysis. Conventional sample preparation and clean-up methods prior to the analysis of biological fluids such as liquid-liquid extraction, solid-phase extraction, or protein precipitation are time-consuming, tedious, and can negatively affect target recovery and detection sensitivity. An alternative or complementary strategy is the use of an off-line or on-line in situ derivatization technique. In situ derivatization can be incorporated to directly derivatize target analytes in their native biological matrices, without any prior sample clean-up methods, to substitute or even enhance the extraction and preconcentration efficiency of these traditional sample preparation methods. Designed appropriately, it can reduce the number of sample preparation steps necessary prior to analysis. Moreover, in situ derivatization can be used to enhance the performance of the developed liquid chromatography with mass spectrometry-based bioanalysis methods regarding stability, chromatographic separation, selectivity, and ionization efficiency. This review presents an overview of the commonly used in situ derivatization techniques coupled to liquid chromatography with mass spectrometry-based bioanalysis to guide and to stimulate future research. PMID:26496130

  7. Detailed molecular characterization of castor oil ethoxylates by liquid chromatography multistage mass spectrometry.

    Science.gov (United States)

    Nasioudis, Andreas; van Velde, Jan W; Heeren, Ron M A; van den Brink, Oscar F

    2011-10-01

    The molecular characterization of castor oil ethoxylates (CASEOs) was studied by reverse-phase liquid chromatography (RPLC) mass spectrometry (MS) and multistage mass spectrometry (MS(n)). The developed RPLC method allowed the separation of the various CASEO components, and especially, the baseline separation of multiple nominal isobars (same nominal mass) and isomers (same exact mass). MS and MS(n) were used for the determination and structure elucidation of various structures and for the discrimination of the isobars and isomers. Different ionization techniques and adduct ions were also tested for optimization of the MS detection and the MS(n) fragmentation. A unique fragmentation pathway of ricinoleic acid is proposed, which can be used as a marker of the polymerization process and the topology of ethoxylation in the CASEO. In addition, characteristic neutral losses of ricinoleic acid reveal its (terminal or internal) position in the molecule.

  8. Direct analysis of volatile fatty acids in marine sediment porewater by two-dimensional ion chromatography-mass spectrometry

    DEFF Research Database (Denmark)

    Glombitza, Clemens; Pedersen, Jeanette; Røy, Hans;

    2014-01-01

    by two-dimensional ion chromatography-mass spectrometry (2D IC-MS). The first chromatographic dimension is used to separate the VFAs from the inorganic ions whereas the second dimension separates the individual VFAs. Quantification and identification are achieved by online mass spectrometry in selected...

  9. Tools to discover anionic and nonionic polyfluorinated alkyl surfactants by liquid chromatography electrospray ionisation mass spectrometry

    DEFF Research Database (Denmark)

    Trier, Xenia; Granby, Kit; Christensen, Jan H.

    2011-01-01

    A tiered approach is proposed for the discovery of unknown anionic and nonionic polyfluorinated alkyl surfactants (PFASs) by reversed phase ultra high performance liquid chromatography (UHPLC) – negative electrospray ionisation – quadrupole time of flight mass spectrometry (UHPLC......–ESI−–QTOF–MS). The chromatographic separation, ionisation and detection of PFASs mixtures, was achieved at high pH (pH=9.7) with NH4OH as additive. To distinguish PFASs from other chemicals we used the characteristic negative mass defects of PFASs, their specific losses of 20Da (HF) and the presence of series of chromatographic...

  10. Quantitative analysis of abused drugs in physiological fluids by gas chromatography/chemical ionization mass spectrometry

    International Nuclear Information System (INIS)

    Methods have been developed for quantitative analysis of commonly abused drugs in physiological fluids using gas chromatography/chemical ionization mass spectrometry. The methods are being evaluated in volunteer analytical and toxicological laboratories, and analytical manuals describing the methods are being prepared. The specific drug and metabolites included in this program are: Δ9-tetrahydrocannabinol, methadone, phencyclidine, methaqualone, morphine, amphetamine, methamphetamine, mescaline, 2,5-dimethoxy-4-methyl amphetamine, cocaine, benzoylecgonine, diazepam, and N-desmethyldiazepam. The current analytical methods utilize relatively conventional instrumentation and procedures, and are capable of measuring drug concentrations as low as 1 ng/ml. Various newer techniques such as sample clean-up by high performance liquid chromatography, separation by glass capillary chromatography, and ionization by negative ion chemical ionization are being investigated with respect to their potential for achieving higher sensitivity and specificity, as well as their ability to facilitate simultaneous analysis of more than one drug and metabolite. (Auth.)

  11. Differentiation of endogenous and exogenous steroids by gas chromatography-combustion-mass spectrometry isotope ratio

    International Nuclear Information System (INIS)

    Urinary steroids profiles are used to control the misuse of endogenous steroids such as testosterone and dihydrotestosterone. The testosterone/epistestosterone ratio, measured by Gas Chromatography-Mass Spectrometry, is used to control testosterone administration. When T/E ratio is higher than 4, consumption of testosterone or its precursors is suspected. Recent researches have demonstrated the effectiveness of Carbon Isotope Ratio Mass Spectrometry to detect and confirm endogenous steroids administration. The ratio of the two stable carbon isotopes 13C and 12C allows the differentiation of natural and synthetic steroids because synthetic steroids have lower 13C abundance. In fact, the carbon isotope ratios can be used to determine endogenous steroids administration even when testosterone/epistestosterone ratio is at its normal value. In the current work, some of the most important aspects related to differentiation of endogenous and exogenous steroids by means of Gas Chromatography-Combustion-Isotope Ratio Mass Spectrometry are discussed. Also, this article provides a review about the purification and sample preparation previous to the analysis, and diet effects on carbon isotope ratio of endogenous anabolics steroids is presented too

  12. Analysis of aromatic hydrocarbons in petroleum fractions using gas chromatography, mass spectrometry and mass fragmentrography

    Energy Technology Data Exchange (ETDEWEB)

    Kubelka, V.

    1980-01-01

    Mass spectrometry in combination with gas chrom. used to analyze hydrocarbon mixtures results in qualit. and semi-quant. data regarding composition of the analyzed mixture. Use of mass fragmentrography during chromatographic separation will allow simultaneous recording of changes in intensity of characteristic ions and thus determine the retention index, for this substance. Combining mass spectre and retention index, it is possible to identify the given subst. or limit the number of possible combinations.

  13. Application of Pyrolysis Gas Chromatography/Mass Spectrometry in Lacquer Research: A Review

    Directory of Open Access Journals (Sweden)

    Xiao-Ming Ma

    2014-01-01

    Full Text Available Examination of thermal degradation of natural and synthetic lacquer films by pyrolysis-gas chromatography with mass spectrometry (Py-GC/MS is reviewed. Due to the instantaneous heating decomposition, side reactions of internal or intermediate samples hardly occur, and the pyrolysis products can be retrieved without any change. Py-GC/MS has been used to analyze the composition of insoluble polymers and investigate degradation of resin materials. Lacquer film is a cross-linked polymer that is insoluble in any solvent. The aim of this review is to describe the application of Py-GC/MS to the analysis of lacquer, including natural lacquer saps, synthetic lacquer derivatives, and their films. After analyzing the chemical structures of the specific pyrolysis products by mass spectrometry, the lacquer tree species and growing region can be determined. These results have great significance for the protection and restoration of lacquer-coated cultural treasures.

  14. Recent advances of liquid chromatography-(tandem) mass spectrometry in clinical and forensic toxicology - An update.

    Science.gov (United States)

    Remane, Daniela; Wissenbach, Dirk K; Peters, Frank T

    2016-09-01

    Liquid chromatography (LC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) is a well-established and widely used technique in clinical and forensic toxicology as well as doping control especially for quantitative analysis. In recent years, many applications for so-called multi-target screening and/or quantification of drugs, poisons, and or their metabolites in biological matrices have been developed. Such methods have proven particularly useful for analysis of so-called new psychoactive substances that have appeared on recreational drug markets throughout the world. Moreover, the evolvement of high resolution MS techniques and the development of data-independent detection modes have opened new possibilities for applications of LC-(MS/MS) in systematic toxicological screening analysis in the so called general unknown setting. The present paper will provide an overview and discuss these recent developments focusing on the literature published after 2010.

  15. Integrated gas and liquid chromatography tandem mass spectrometry for forensic engine lubricating oil identification

    International Nuclear Information System (INIS)

    This paper presented a method for rapid chemical characterization of engine lubricating oils. Motor oils typically contain up to 5 per cent additives, such as detergent, antifoamant, dispersant, emulsifier, antioxidant, friction modifier, colour stabilizer and corrosion inhibitors. Different lube oil products usually have either different additives in various concentrations. As such, the formulation of additives in lube oil products should provide fingerprint information for forensic oil identification. The characterization method used in this study was based on a newly developed fast solvent liquid-liquid sample extraction procedure that combined the use of both liquid chromatography tandem mass spectrometry (LC-MS) and gas chromatography-mass spectrometry (GC-MS) simultaneously together with gas chromatography flame ionization detection (GC-FID). The method was used on a blind sample testing of commercially available engine lubricating products. The sample extraction procedure involved extraction of additives into acidified acetonitrile, two hexane washes of hydrophobic components of lube oil, filtration, and dilution with solvents for GC and LC analysis. The new method proved to be rapid and easy to use. It enabled the identification of unknown additives and hydrocarbons in many different types of fresh lube oils. Further tests will be needed to determine if this method can be used on real-world weathered samples. The method is part of an ongoing effort to deal with mysterious chemical spills, an important aspect of environmental protection and emergency preparedness. 8 refs., 7 figs

  16. Preventive doping control analysis: Liquid and gas chromatography time-to-flight mass spectrometry for detection of designer steriods

    NARCIS (Netherlands)

    Georgakopoulos, C.G.; Vonaparti, A.; Stamou, M.; Kiousi, P.; Lyris, E.; Angelis, Y.S.; Tsoupras, G.; Wuest, B.; Nielen, M.W.F.; Panderi, I.; Koupparis, M.

    2007-01-01

    A new combined doping control screening method for the analysis of anabolic steroids in human urine using liquid chromatography/electrospray ionization orthogonal acceleration time-of-flight mass spectrometry (LCoaTOFMS) and gas chromatography/electron ionization orthogonal acceleration time-of-flig

  17. Determination of polar organophosphorus pesticides in vegetables and fruits using liquid chromatography with tandem mass spectrometry: Selection of extraction solvent

    NARCIS (Netherlands)

    Mol, H.G.J.; Dam, R.C.J. van; Steijger, O.M.

    2003-01-01

    A method based on liquid chromatography (LC)-mass spectrometry (MS)/MS was developed for sensitive determination of a number of less gas chromatography (GC)-amenable organophosphorus pesticides (OPs; acephate, methamidophos, monocrotophos, omethoate, oxydemeton-methyl and vamidothion) in cabbage and

  18. Chemical characterization using gas chromatography/mass spectrometry of two extracts from Phyllanthus orbicularis HBK

    International Nuclear Information System (INIS)

    The objective of this paper was the chemical characterization of two extracts from Phyllanthus orbicularis HBK through gas chromatography/mass spectrometry. To this end, maceration with N-hexane and ethyl acetate was used to obtain the respective extracts. The study of the hexane extract identified 17 components in which hydrocarbonate structures prevailed, mainly cyclooctacosane. In the ethyl acetate extract, 19 compounds were detected, being the terpenoids the predominant, although the most abundant was sterol g-sitosterol. For the first time, the identified compounds are reported for this species

  19. Quantitative determination of capsaicinoids by liquid chromatography-electrospray mass spectrometry.

    Science.gov (United States)

    Thompson, Robert Q; Phinney, Karen W; Welch, Michael J; White, Edward

    2005-04-01

    Eight naturally occurring capsaicinoids have been determined in Capsicum by use of high-purity standards, with norcapsaicin as an internal standard. The solid standards were rigorously checked for purity. The sensitivity of electrospray ionization (ESI), atmospheric-pressure chemical ionization (APCI), and coordination ion-spray (CIS; with silver) toward the capsaicinoids were measured and compared. The highest sensitivity was found for positive-ion ESI. Method validation of the liquid chromatography-ESI-mass spectrometry (LC-ESI-MS) determination is reported, including tests for repeatability (4%), detection limit (5 pg injected), linear range (20-6 ng injected), quantitation (excellent linearity; pepper fruits were quantified. PMID:15803309

  20. Determination of ketone bodies in blood by headspace gas chromatography-mass spectrometry

    DEFF Research Database (Denmark)

    Holm, Karen Marie Dollerup; Linnet, Kristian; Rasmussen, Brian Schou;

    2010-01-01

    A gas chromatography-mass spectrometry (GC-MS) method for determination of ketone bodies (ß-hydroxybutyrate, acetone, and acetoacetate) in blood is presented. The method is based on enzymatic oxidation of D-ß-hydroxybutyrate to acetoacetate, followed by decarboxylation to acetone, which...... was quantified by the use of headspace GC-MS using acetone-(13)C(3) as an internal standard. The developed method was found to have intra- and total interday relative standard deviations acetone+acetoacetate levels (~25 to 8300 µM) and D-ß-hydroxybutyrate levels (~30 to 16500 µM). Recovery values varied...

  1. Determination of cocaine in brazilian paper currency by capillary gas chromatography/mass spectrometry

    Directory of Open Access Journals (Sweden)

    Enrico Di Donato

    2007-01-01

    Full Text Available The presence of illicit drugs such as cocaine and marijuana in US paper currency is very well demonstrated. However, there is no published study describing the presence of cocaine and/or other illicit drugs in Brazilian paper currency. In this study, Brazilian banknotes were collected from nine cities, extracted and analyzed by capillary gas chromatography/mass spectrometry, in order to investigate the presence of cocaine. Bills were extracted with deionized water followed by ethyl acetate. Results showed that 93% of the bills presented cocaine in a concentration range of 2.38-275.10 µg/bill.

  2. Analysis of the citric acid cycle intermediates using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Kombu, Rajan S; Brunengraber, Henri; Puchowicz, Michelle A

    2011-01-01

    Researchers view analysis of the citric acid cycle (CAC) intermediates as a metabolomic approach to identifying unexpected correlations between apparently related and unrelated pathways of metabolism. Relationships of the CAC intermediates, as measured by their concentrations and relative ratios, offer useful information to understanding interrelationships between the CAC and metabolic pathways under various physiological and pathological conditions. This chapter presents a relatively simple method that is sensitive for simultaneously measuring concentrations of CAC intermediates (relative and absolute) and other related intermediates of energy metabolism using gas chromatography-mass spectrometry.

  3. Determination of 4-Chloroindole-3-Acetic Acid Methyl Ester in Lathyrus Vicia and Pisum by Gas Chromatography - Mass Spectrometry

    DEFF Research Database (Denmark)

    Engvild, Kjeld Christensen; Egsgaard, Helge; Larsen, Elfinn

    1980-01-01

    4-Chloroindole-3-acetic acid methyl ester was identified unequivocally in Lathyrus latifolius L., Vicia faba L. and Pisum sativum L. by thin layer chromatography, gas chromatography and mass spectrometry. The gas chromatographic system was able to separate underivatized chloroindole-3-acetic acid...... methyl ester isomers. The quantitative determination of 4-chloroindole-3-acetic acid methyl ester in immature seeds of these three species was performed by gas chromatographymass spectrometry using deuterium labelled 4-chloro-indole-3-acetic acid methyl ester as an internal standard. P. sativum...

  4. Gelatin quantification by oxygen-18 labeling and liquid chromatography-high-resolution mass spectrometry.

    Science.gov (United States)

    Sha, Xiao-Mei; Tu, Zong-Cai; Wang, Hui; Huang, Tao; Duan, Deng-Le; He, Na; Li, De-Jun; Xiao, Hui

    2014-12-10

    Combined with high-performance liquid chromatography (HPLC) and linear-ion trap/Orbitrap high-resolution mass spectrometry, trypsin-catalyzed (16)O-to-(18)O exchange was used to establish an accurate quantitative method for bovine or porcine gelatin. The sophisticated modifications for these two mammalian gelatins were unambiguously identified by accurate mass and tandem mass spectrometry. Eighteen marker peptides were successfully identified for the bovine and porcine gelatin, respectively. The gelatins were subjected to (18)O or (16)O labeling in the presence of trypsin and mixed together in various ratios for quantification. All of the (18)O-labeled peptides were also confirmed by accurate mass and tandem mass spectrometry. The 10 marker peptides with the strongest signals were chosen to calculate the average ratios of (18)O-labeled and (16)O-labeled gelatin. The measured ratios of (18)O-labeled and (16)O-labeled peptides were very close to the mixing ratios of 20:1, 5:1, 1:1, and 1:5 with low standard deviation values. The samples with a mixing ratio of 1:1 (18)O-labeled and (16)O-labeled peptides were determined to 1.00 and 0.99 with standard deviations of 0.02 and 0.04 for bovine and porcine gelatins, respectively, indicating the high accuracy of this method. Trypsin-catalyzed (18)O labeling was proved to be an excellent internal calibrant for gelatins. When combined with HPLC and high-resolution mass spectrometry, it is an accurate and sensitive quantitative method for gelatin in the food industry. PMID:25404505

  5. Hyphenation of aqueous liquid chromatography to pyrolysis-gas chromatography and mass spectrometry for the comprehensive characterization of water-soluble polymers

    NARCIS (Netherlands)

    E.R. Kaal; M. Kurano; M. Geissler; H.-G. Janssen

    2008-01-01

    A recently developed hyphenated system for "organic" size-exclusion chromatography-pyrolysis-gas chromatography-mass spectrometry (SEC-Py-GC-MS) is adapted to allow the use of aqueous LC eluents as applied in the characterization of water-soluble polymers. The system uses syringe-based transfer of m

  6. Analyses of acute kidney injury biomarkers by ultra-high performance liquid chromatography with mass spectrometry.

    Science.gov (United States)

    Al Za'abi, Mohammed; Ali, Badreldin H; ALOthman, Zeid A; Ali, Imran

    2016-01-01

    The newly developed acute kidney injury biomarkers are very important for the early and timely detection of kidney diseases. This review contains details of the analyses of several acute kidney injury biomarkers using ultra-high performance liquid chromatography-mass spectrometry in urine and plasma samples. In this review we attempt to discuss some aspects of the types of the biomarkers, patents, sample preparation, and the analyses. Besides, efforts were also made to discuss the possible uses of superficially porous (core-shell) columns in traditional and inexpensive high-performance liquid chromatography instruments. Additionally, the challenges and the future prospects are also highlighted. The present review will be useful for the academicians, scientists, and clinicians for the early detection of acute kidney injury biomarkers.

  7. Improved method for the determination of hydroxymethylfurfural in baby foods using liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Gökmen, Vural; Senyuva, Hamide Z

    2006-04-19

    An improved analytical method for the rapid, reliable, and sensitive determination of hydroxymethylfurfural (HMF) in baby foods is described. It entailed aqueous extraction from food matrix with simultaneous clarification using Carrez I and II reagents, solid-phase extraction cleanup using Oasis HLB, and analysis by liquid chromatography-mass spectrometry. A narrow-bore column allowed fast chromatographic separation with good resolution of HMF and matrix coextractives. In positive atmospheric pressure chemical ionization conditions, precursor and compound-specific ions were sensitively detected in selected ion monitoring mode. Sample preparation with efficient cleanup followed by fast chromatographic analysis allowed the analysis to be completed in <20 min. Recovery ranged between 91.8 and 94.7% for spiking levels of 0.25, 1.0, and 5.0 mg/kg HMF in cereal-based baby foods. The method was shown to be successful when using liquid chromatography coupled to ultraviolet detection at 285 nm. PMID:16608199

  8. Development and application of liquid chromatography coupled to isotope ratio mass spectrometry

    International Nuclear Information System (INIS)

    Stable isotope analysis has found widespread applications in various disciplines such as archaeology, geochemistry, biology, food authenticity, and forensic science. Coupling chromatography to isotope ratio mass spectrometry for compound-specific isotope analysis (CSIA) is a trend, as it provides several advantages over bulk isotope analysis, e.g., relatively simple sample preparation, the ability to measure individual compounds in a complex mixture in one run, and the reduced sample size required for precise isotope analysis. Gas chromatography coupled to isotope ratio mass spectrometry (GC/IRMS) has been well-established for compound-specific isotope analysis of volatile organic compounds within the last two decades. However, an interface combining liquid chromatography with isotope ratio mass spectrometry (LC/IRMS) was not commercially available until 2004. The current design of the interface requires using a carbon-free eluent in chromatographic separation. This requirement limits the application of the most frequently used reversed-phase liquid chromatography in CSIA, because the elution strength of water at room temperature is too low to serve as mobile phase in reversed-phase separations. In order to increase the elution strength of water, we propose using high temperature water for chromatographic elution. The polarity of water decreases with an increase of temperature, yielding increased elution strength in reversed-phase columns. Therefore, high temperature water can be used as eluent instead of organic solvent for combining reversed-phase liquid chromatography with isotope ratio mass spectrometry (RPLC/IRMS). Additionally, temperature gradients can replace organic solvent gradients to increase chromatographic resolution. This is very important for LC/IRMS analysis, as precise isotope analysis requires baseline separation of analytes. In this thesis, high-temperature reversed-phase liquid chromatography was coupled to, and for the first time carefully

  9. Development and application of liquid chromatography coupled to isotope ratio mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Lijun

    2014-02-19

    Stable isotope analysis has found widespread applications in various disciplines such as archaeology, geochemistry, biology, food authenticity, and forensic science. Coupling chromatography to isotope ratio mass spectrometry for compound-specific isotope analysis (CSIA) is a trend, as it provides several advantages over bulk isotope analysis, e.g., relatively simple sample preparation, the ability to measure individual compounds in a complex mixture in one run, and the reduced sample size required for precise isotope analysis. Gas chromatography coupled to isotope ratio mass spectrometry (GC/IRMS) has been well-established for compound-specific isotope analysis of volatile organic compounds within the last two decades. However, an interface combining liquid chromatography with isotope ratio mass spectrometry (LC/IRMS) was not commercially available until 2004. The current design of the interface requires using a carbon-free eluent in chromatographic separation. This requirement limits the application of the most frequently used reversed-phase liquid chromatography in CSIA, because the elution strength of water at room temperature is too low to serve as mobile phase in reversed-phase separations. In order to increase the elution strength of water, we propose using high temperature water for chromatographic elution. The polarity of water decreases with an increase of temperature, yielding increased elution strength in reversed-phase columns. Therefore, high temperature water can be used as eluent instead of organic solvent for combining reversed-phase liquid chromatography with isotope ratio mass spectrometry (RPLC/IRMS). Additionally, temperature gradients can replace organic solvent gradients to increase chromatographic resolution. This is very important for LC/IRMS analysis, as precise isotope analysis requires baseline separation of analytes. In this thesis, high-temperature reversed-phase liquid chromatography was coupled to, and for the first time carefully

  10. Gas Chromatography/Atmospheric Pressure Chemical Ionization Tandem Mass Spectrometry for Fingerprinting the Macondo Oil Spill.

    Science.gov (United States)

    Lobodin, Vladislav V; Maksimova, Ekaterina V; Rodgers, Ryan P

    2016-07-01

    We report the first application of a new mass spectrometry technique (gas chromatography combined to atmospheric pressure chemical ionization tandem mass spectrometry, GC/APCI-MS/MS) for fingerprinting a crude oil and environmental samples from the largest accidental marine oil spill in history (the Macondo oil spill, the Gulf of Mexico, 2010). The fingerprinting of the oil spill is based on a trace analysis of petroleum biomarkers (steranes, diasteranes, and pentacyclic triterpanes) naturally occurring in crude oil. GC/APCI enables soft ionization of petroleum compounds that form abundant molecular ions without (or little) fragmentation. The ability to operate the instrument simultaneously in several tandem mass spectrometry (MS/MS) modes (e.g., full scan, product ion scan, reaction monitoring) significantly improves structural information content and sensitivity of analysis. For fingerprinting the oil spill, we constructed diagrams and conducted correlation studies that measure the similarity between environmental samples and enable us to differentiate the Macondo oil spill from other sources. PMID:27281271

  11. [Determination of residual glycol ethers in leather and leather products by gas chromatography/mass spectrometry].

    Science.gov (United States)

    Wang, Ghengyun; Zhang, Weiya; Li, Lixia; Shen, Yalei; Lin, Junfeng; Xie, Tangtang; Chu, Naiqing

    2014-08-01

    An effective method was established for the simultaneous determination of residual glycol ethers in leather and leather products by gas chromatography/mass spectrometry. Glycol ethers in leather and leather products were ultrasonically extracted at 45 °C, using ethyl acetate as the extraction solvent. The extracts were purified by solid phase extraction (SPE) columns, and then analyzed by gas chromatography/mass spectrometry in selected ion monitoring mode. The content of each analyte was calibrated by external standard method. The limit of detection of ethylene glycol ethyl ether (EGEE) was 0. 10 mg/kg under the condition of signal to noise (S/N) of 3 and the limits of the other 11 glycol ethers were all less than 0.05 mg/kg. The spiked recoveries varied from 81. 2% to 95. 5% at three different spiked levels with the relative standard deviations (RSDs) ranged from 1.4% to 6. 6%. The proposed method is simple, rapid and accurate, with the limits of detection much less than the requirements of the Regulation Concerning Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) of European Union. It is applicable to the determination of residual glycol ethers in leather and leather products, and provides a reference for the relevant testing standards.

  12. Degradation study of enniatins by liquid chromatography-triple quadrupole linear ion trap mass spectrometry.

    Science.gov (United States)

    Serrano, A B; Meca, G; Font, G; Ferrer, E

    2013-12-15

    Enniatins A, A1, B and B1 (ENs) are mycotoxins produced by Fusarium spp. and are normal contaminants of cereals and derivate products. In this study, the stability of ENs was evaluated during food processing by simulation of pasta cooking. Thermal treatments at different incubation times (5, 10 and 15 min) and different pH (4, 7 and 10) were applied in an aqueous system and pasta resembling system (PRS). The concentrations of the targeted mycotoxins were determined using liquid chromatography coupled to tandem mass spectrometry. High percentages of ENs reduction (81-100%) were evidenced in the PRS after the treatments at 5, 10 and 15 min of incubation. In contrast to the PRS, an important reduction of the ENs was obtained in the aqueous system after 15 min of incubation (82-100%). In general, no significant differences were observed between acid, neutral and basic solutions. Finally, several ENs degradation products were identified using the technique of liquid chromatography-triple quadrupole linear ion trap mass spectrometry. PMID:23993608

  13. A liquid chromatography-mass spectrometry approach to study "glucosinoloma" in broccoli sprouts.

    Science.gov (United States)

    Maldini, Mariateresa; Baima, Simona; Morelli, Giorgio; Scaccini, Cristina; Natella, Fausta

    2012-09-01

    Glucosinolates are an important class of secondary plant metabolites, possessing health-promoting properties. Young broccoli plants are a very good source of glucosinolates with concentrations several times greater than in mature plants. The aim of our study was to develop a liquid chromatography-mass spectrometry and liquid chromatography/tandem mass spectrometry qualitative and quantitative method for the measure of glucosinolates in broccoli sprouts. The described method provides high sensitivity and specificity, allowing a rapid and simultaneous determination of 14 glucosinolates. The proposed method has been validated for eight glucosinolates: glucobrassicin, glucoraphanin, glucoiberin, glucoerucin, progoitrin, gluconapin, sinigrin and glucocheirolin. The linear range was 1-150 µg ml(-1), the intra-day and inter-day precision values are within 6% and 8% at the lower limit of quantification, while the overall recovery of the eight glucosinolates was 99 ± 9%. This validated method was used successfully for analysis of glucosinolates content of broccoli sprouts grown in different conditions.

  14. Recent progress in polar metabolite quantification in plants using liquid chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Zhiqian Liu; Simone Rochfort

    2014-01-01

    Metabolite analysis or metabolomics is an impor-tant component of systems biology in the post-genomic era. Although separate liquid chromatography (LC) methods for quantification of the major classes of polar metabolites of plants have been available for decades, a single method that enables simultaneous determination of hundreds of polar metabolites is possible only with gas chromatography-mass spectrometry (GC-MS) techniques. The rapid expansion of new LC stationary phases in the market and the ready access of mass spectrometry in many laboratories provides an excellent opportunity for developing LC-MS based methods for multi-target quantification of polar metabolites. Although various LC-MS methods have been developed over the last 10 years with the aim to quantify one or more classes of polar compounds in different matrices, currently there is no consensus LC-MS method that is widely used in plant metabolomics studies. The most promising methods applicable to plant metabolite analysis wil be reviewed in this paper and the major problems encountered highlighted. The aim of this review is to provide plant scientists, with limited to moderate experience in analytical chemistry, with up-to-date and simplified information regarding the current status of polar metabolite analysis using LC-MS techniques.

  15. Analysis of aristolochic acids, aristololactams and their analogues using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Yu, Jie; Ma, Chao-Mei; Wang, Xuan; Shang, Ming-Ying; Hattori, Masao; Xu, Feng; Jing, Yu; Dong, Shi-Wen; Xu, Yu-Qiong; Zhang, Cui-Ying; Cai, Shao-Qing

    2016-08-01

    More than 80 aristolochic acids (AAs) and aristololactams (ALs) have been found in plants of the Aristolochiaceae family, but relatively few have been fully studied. The present study aimed at developing and validating a liquid chromatography tandem mass spectrometry (LC/MS(n)) for the analysis of these compounds. We characterized the fragmentation behaviors of 31 AAs, ALs, and their analogues via high performance liquid chromatography coupled with electrospray ionization mass spectrometry. We summarized their fragmentation rules and used these rules to identify the constituents contained in Aristolochia contorta, Ar. debilis, Ar. manshurensis, Ar. fangchi, Ar. cinnabarina, and Ar. mollissima. The AAs and ALs showed very different MS behaviors. In MS(1) of AAs, the characteristic pseudomolecular ions were [M + NH4](+), [M + H](+), and [M + H - H2O](+). However, only [M + H](+) was found in the MS(1) of ALs, which was simpler than that of AAs. Distinct MS(n)fragmentation patterns were found for AAs and ALs, showing the same skeleton among the different substituent groups. The distribution of the 31 constituents in the 6 species of Aristolochia genus was reported for the first time. 25 Analogues of AAs and ALs were detected in this genus. A hierarchical schemes and a calculating formula of the molecular formula of these nitrophenanthrene carboxylic acids and their lactams were proposed. In conclusion, this method could be applied to identification of similar unknown constituents in other plants. PMID:27608953

  16. Simultaneous determination of three organophosphorus pesticides in different food commodities by gas chromatography with mass spectrometry.

    Science.gov (United States)

    Vijaya Bhaskar Reddy, Ambavaram; Yusop, Zulkifli; Jaafar, Jafariah; Bin Aris, Azmi; Abdul Majid, Zaiton; Umar, Khalid; Talib, Juhaizah

    2016-06-01

    A sensitive and selective gas chromatography with mass spectrometry method was developed for the simultaneous determination of three organophosphorus pesticides, namely, chlorpyrifos, malathion, and diazinon in three different food commodities (milk, apples, and drinking water) employing solid-phase extraction for sample pretreatment. Pesticide extraction from different sample matrices was carried out on Chromabond C18 cartridges using 3.0 mL of methanol and 3.0 mL of a mixture of dichloromethane/acetonitrile (1:1 v/v) as the eluting solvent. Analysis was carried out by gas chromatography coupled with mass spectrometry using selected-ion monitoring mode. Good linear relationships were obtained in the range of 0.1-50 μg/L for chlorpyrifos, and 0.05-50 μg/L for both malathion and diazinon pesticides. Good repeatability and recoveries were obtained in the range of 78.54-86.73% for three pesticides under the optimized experimental conditions. The limit of detection ranged from 0.02 to 0.03 μg/L, and the limit of quantification ranged from 0.05 to 0.1 μg/L for all three pesticides. Finally, the developed method was successfully applied for the determination of three targeted pesticides in milk, apples, and drinking water samples each in triplicate. No pesticide was found in apple and milk samples, but chlorpyrifos was found in one drinking water sample below the quantification level. PMID:27095506

  17. Determination of bromate in drinking water by ultraperformance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Alsohaimi, Ibrahim Hotan; Alothman, Zeid Abdullah; Khan, Mohammad Rizwan; Abdalla, Mohammad Abulhassan; Busquets, Rosa; Alomary, Ahmad Khodran

    2012-10-01

    Bromate is a byproduct formed as a result of disinfection of bromide-containing source water with ozone or hypochlorite. The International Agency for Research on Cancer has recognized bromate as a possible human carcinogen, thus it is essential to determine in drinking water. Present work highlights a development of sensitive and fast analytical method for bromate determination in drinking water by using ultraperformance liquid chromatography-tandem mass spectrometry. The quality parameters of the developed method were established, obtaining very low limit of detection (0.01 ng/mL), repeatability and reproducibility have been found to be less than 3% in terms of relative standard deviation when analyzing a bromate standard at 0.05 μg/mL with 0.4 min analysis time. Developed method was applied for the analysis of metropolitan and bottled water from Saudi Arabia; 22 samples have been analyzed. Bromate was detected in the metropolitan water samples (from desalinization source) at concentrations ranging between 3.43 and 75.04 ng/mL and in the bottled water samples at concentrations ranging between 2.07 and 21.90 ng/mL. Moreover, in comparison to established analytical methods such as liquid chromatography-tandem mass spectrometry, the proposed method was found to be very sensitive, selective and rapid for the routine analysis of bromate at low level in drinking water.

  18. Determination of parabens in serum by liquid chromatography-tandem mass spectrometry: Correlation with lipstick use.

    Science.gov (United States)

    Tahan, Gabriella Padovani; Santos, Nayara de Kássia Souza; Albuquerque, Ana Carolina; Martins, Isarita

    2016-08-01

    Parabens are the most widely used preservative and are considered to be relatively safe compounds. However, studies have demonstrated that they may have estrogenic activity, and there is ongoing debate regarding the safety and potential cancer risk of using products containing these compounds. In the present work, liquid chromatography-tandem mass spectrometry was applied to determine methylparaben and propylparaben concentrations in serum, and the results were correlated with lipstick application. Samples were analyzed using liquid-liquid extraction, followed by liquid chromatography-tandem mass spectrometry. The validation results demonstrated the linearity of the method over a range of 1-20 ng/mL, in addition to the method's precision and accuracy. A statistically significant difference was demonstrated between serum parabens in women who used lipstick containing these substances compared with those not using this cosmetic (p = 0.0005 and 0.0016, respectively), and a strong association was observed between serum parabens and lipstick use (Spearman correlation = 0.7202). PMID:27154569

  19. Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Highlights: · We determine methylmercury in serum and plasma using isotope dilution calibration. · Separation by gas chromatography and detection by inductively coupled plasma mass spectrometry. · Data for 50 specimens provides first reference range for methylmercury in serum. · Serum samples shown to be stable for 11 months in refrigerator. - Abstract: A method for the determination of methylmercury in plasma and serum samples was developed. The method uses isotope dilution with 198Hg-labeled methylmercury, extraction into dichloromethane, back-extraction into water, aqueous-phase ethylation, purge and trap collection, thermal desorption, separation by gas chromatography, and mercury isotope specific detection by inductively coupled plasma mass spectrometry. By spiking 2 mL sample with 1.2 ng tracer, measurements in a concentration interval of (0.007-2.9) μg L-1 could be performed with uncertainty amplification factors -1 was estimated at 10 times the standard deviation of concentrations measured in preparation blanks. Within- and between-run relative standard deviations were -1, 0.35 μg L-1 and 2.8 μg L-1, with recoveries in the range 82-110%. Application of the method to 50 plasma/serum samples yielded a median (mean; range) concentration of methylmercury of 0.081 (0.091; -1. This is the first time methylmercury has been directly measured in this kind of specimen, and is therefore the first estimate of a reference range.

  20. Liquid chromatography combined with mass spectrometry for 13C isotopic analysis in life science research.

    Science.gov (United States)

    Godin, Jean-Philippe; Fay, Laurent-Bernard; Hopfgartner, Gérard

    2007-01-01

    Among the different disciplines covered by mass spectrometry, measurement of (13)C/(12)C isotopic ratio crosses a large section of disciplines from a tool revealing the origin of compounds to more recent approaches such as metabolomics and proteomics. Isotope ratio mass spectrometry (IRMS) and molecular mass spectrometry (MS) are the two most mature techniques for (13)C isotopic analysis of compounds, respectively, for high and low-isotopic precision. For the sample introduction, the coupling of gas chromatography (GC) to either IRMS or MS is state of the art technique for targeted isotopic analysis of volatile analytes. However, liquid chromatography (LC) also needs to be considered as a tool for the sample introduction into IRMS or MS for (13)C isotopic analyses of non-volatile analytes at natural abundance as well as for (13)C-labeled compounds. This review presents the past and the current processes used to perform (13)C isotopic analysis in combination with LC. It gives particular attention to the combination of LC with IRMS which started in the 1990's with the moving wire transport, then subsequently moved to the chemical reaction interface (CRI) and was made commercially available in 2004 with the wet chemical oxidation interface (LC-IRMS). The LC-IRMS method development is also discussed in this review, including the possible approaches for increasing selectivity and efficiency, for example, using a 100% aqueous mobile phase for the LC separation. In addition, applications for measuring (13)C isotopic enrichments using atmospheric pressure LC-MS instruments with a quadrupole, a time-of-flight, and an ion trap analyzer are also discussed as well as a LC-ICPMS using a prototype instrument with two quadrupoles. PMID:17853432

  1. Sheath liquid effects in capillary high-performance liquid chromatography-electrospray mass spectrometry of oligonucleotides.

    Science.gov (United States)

    Huber, C G; Krajete, A

    2000-02-18

    Fused-silica capillary columns of 200 microm inner diameter were packed with micropellicular, octadecylated, 2.3 microm poly(styrene-divinylbenzene) particles and applied to the separation of oligonucleotides by ion-pair reversed-phase high-performance liquid chromatography. Oligonucleotides were eluted at 50 degrees C with gradients of 3-13% acetonitrile in 50 mM triethylammonium bicarbonate. Addition of sheath liquid to the column effluent allowed the detection of oligonucleotides by electrospray ionization mass spectrometry using full-scan data acquisition with a detectability comparable to that obtained with UV detection. The signal-to-noise ratios with different sheath liquids increased in the order isopropanolmass spectra mainly because of increased background noise. Only a few charge states were observed in the mass spectra of oligonucleotides because of charge state reduction due to the presence of carbonic acid in the eluent. With triethylammonium hydrogencarbonate as chromatographic eluent and acetonitrile as sheath liquid, very few cation adducts of oligonucleotides were observed in the mass spectra. However, the presence of small amounts of monopotassium adducts enabled the calculation of the charge state of multiply charged ions. With acetonitrile as sheath liquid, 710 amol of a 16-mer oligonucleotide were detected using selected ion monitoring data acquisition with a signal-to-noise ratio of 3:1. Finally, capillary ion-pair reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry was

  2. Online Hydrophobic Interaction Chromatography-Mass Spectrometry for Top-Down Proteomics.

    Science.gov (United States)

    Chen, Bifan; Peng, Ying; Valeja, Santosh G; Xiu, Lichen; Alpert, Andrew J; Ge, Ying

    2016-02-01

    Recent progress in top-down proteomics has led to a demand for mass spectrometry (MS)-compatible chromatography techniques to separate intact proteins using volatile mobile phases. Conventional hydrophobic interaction chromatography (HIC) provides high-resolution separation of proteins under nondenaturing conditions but requires high concentrations of nonvolatile salts. Herein, we introduce a series of more-hydrophobic HIC materials that can retain proteins using MS-compatible concentrations of ammonium acetate. The new HIC materials appear to function as a hybrid form of conventional HIC and reverse phase chromatography. The function of the salt seems to be preserving protein structure rather than promoting retention. Online HIC-MS is feasible for both qualitative and quantitative analysis. This is demonstrated with standard proteins and a complex cell lysate. The mass spectra of proteins from the online HIC-MS exhibit low charge-state distributions, consistent with those commonly observed in native MS. Furthermore, HIC-MS can chromatographically separate proteoforms differing by minor modifications. Hence, this new HIC-MS combination is promising for top-down proteomics.

  3. Elemental labelling combined with liquid chromatography inductively coupled plasma mass spectrometry for quantification of biomolecules: A review

    OpenAIRE

    Kretschy, Daniela; Koellensperger, Gunda; Hann, Stephan

    2012-01-01

    This article reviews novel quantification concepts where elemental labelling is combined with flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS) or liquid chromatography inductively coupled plasma mass spectrometry (LC–ICP-MS), and employed for quantification of biomolecules such as proteins, peptides and related molecules in challenging sample matrices. In the first sections an overview on general aspects of biomolecule quantification, as well as of labelling will be pre...

  4. Liquid chromatography-mass spectrometry coupling by the intermediary of a liquid micro chromatography-electro spray interface; Couplage chromatographie liquide-spectrometrie de masse par l`intermediaire d`une interface electrospray-microchromatographie liquide

    Energy Technology Data Exchange (ETDEWEB)

    Gillard Factor, C.

    1996-12-06

    The objective of this work is to realize a liquid chromatography- mass spectrometry coupling by the intermediary of an electro spray interface and the evaluation of performances of tis analytical tool to study pollutants in water, and more particularly pesticides whom maximum admissible concentration in a table water is 0.1{mu}g/l. This study has allowed to bring to the fore the interest of the ionization mode by electro spray in a LC/MS coupling to identify and quantify pesticides in the state of traces without treating the sample. Then, it was demonstrated the usefulness of this analytical tool to detect high molecular masses molecules. (N.C.)

  5. Determination of constituents of essential oil from Angelica sinensis by gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    WU Ming-jian; SUN Xian-jun; DAI Yuan-hui; GUO Fang-qiu; HUANG Lan-fang; LIANG Yi-zeng

    2005-01-01

    Gas chromatography-mass spectrometry (GC-MS) coupled with chemometric resolution upon two-dimensional data was employed to analyze the constituents of essential oils of Angelica sinensis. Constituents in essential oils of Angelica sinensis root were identified by GC-MS with the help of subwindow factor analysis (SFA) method resolving two-dimensional original data into mass spectra and chromatograms. 76 of 97 separated constituents in essential oil of Angelica sinensis root were identified and quantified, and they account for about 91.36% of the total content. The results show that ligustilide, butylene phthalide, 2-methoxy-4-vinylphenol, carvacrol, allo-ocimene,2,6,6-trimethylbicyclo-[3,1,1]hept-2-ene are the main constituents in essential oil of Angelica sinensis root.

  6. The determination of 5-fluorouracil in human plasma by a gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    A gas chromatography-mass spectrometry method for the determination of 5-fluorouracil in human plasma is described. The method involves a single extraction procedure with 10 ml of isopropanol-eth-er(20:80) solution and pentafluoro-benzylation. Samples were injected using an automatic injector, followed by separation on a nonpolar capillary column and detection with a mass selective detector(MSD). No en-dogeneous compounds were found to interfere. The detection limit, based upon an assayed plasma volume of 0.5, was 3 ng/ml. The extraction yield was found to be above 80%. Plasma 5-FU concentrations were det-ermined by this method in about 500 plasma samples from cancer patients undergoing treatment with 5-FU. This method is suitable for monitoring of 5-FU in plasma of cancer patients

  7. Development, validation and determination of multiclass pesticide residues in cocoa beans using gas chromatography and liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Zainudin, Badrul Hisyam; Salleh, Salsazali; Mohamed, Rahmat; Yap, Ken Choy; Muhamad, Halimah

    2015-04-01

    An efficient and rapid method for the analysis of pesticide residues in cocoa beans using gas and liquid chromatography-tandem mass spectrometry was developed, validated and applied to imported and domestic cocoa beans samples collected over 2 years from smallholders and Malaysian ports. The method was based on solvent extraction method and covers 26 pesticides (insecticides, fungicides, and herbicides) of different chemical classes. The recoveries for all pesticides at 10 and 50 μg/kg were in the range of 70-120% with relative standard deviations of less than 20%. Good selectivity and sensitivity were obtained with method limit of quantification of 10 μg/kg. The expanded uncertainty measurements were in the range of 4-25%. Finally, the proposed method was successfully applied for the routine analysis of pesticide residues in cocoa beans via a monitoring study where 10% of them was found positive for chlorpyrifos, ametryn and metalaxyl. PMID:25442595

  8. Triacylglycerol profiling of microalgae strains for biofuel feedstock by liquid chromatography-high-resolution mass spectrometry.

    Science.gov (United States)

    MacDougall, Karen M; McNichol, Jesse; McGinn, Patrick J; O'Leary, Stephen J B; Melanson, Jeremy E

    2011-11-01

    Biofuels from photosynthetic microalgae are quickly gaining interest as a viable carbon-neutral energy source. Typically, characterization of algal feedstock involves breaking down triacylglycerols (TAG) and other intact lipids, followed by derivatization of the fatty acids to fatty acid methyl esters prior to analysis by gas chromatography (GC). However, knowledge of the intact lipid profile could offer significant advantages for discovery stage biofuel research such as the selection of an algal strain or the optimization of growth and extraction conditions. Herein, lipid extracts from microalgae were directly analyzed by ultra-high pressure liquid chromatography-mass spectrometry (UHPLC-MS) using a benchtop Orbitrap mass spectrometer. Phospholipids, glycolipids, and TAGs were analyzed in the same chromatographic run, using a combination of accurate mass and diagnostic fragment ions for identification. Using this approach, greater than 100 unique TAGs were identified over the six algal strains studied and TAG profiles were obtained to assess their potential for biofuel applications. Under the growth conditions employed, Botryococcus braunii and Scenedesmus obliquus yielded the most comprehensive TAG profile with a high abundance of TAGs containing oleic acid. PMID:21915640

  9. Thin layer chromatography coupled to paper spray ionization mass spectrometry for cocaine and its adulterants analysis.

    Science.gov (United States)

    De Carvalho, Thays C; Tosato, Flavia; Souza, Lindamara M; Santos, Heloa; Merlo, Bianca B; Ortiz, Rafael S; Rodrigues, Rayza R T; Filgueiras, Paulo R; França, Hildegardo S; Augusti, Rodinei; Romão, Wanderson; Vaz, Boniek G

    2016-05-01

    Thin layer chromatography (TLC) is a simple and inexpensive type of chromatography that is extensively used in forensic laboratories for drugs of abuse analysis. In this work, TLC is optimized to analyze cocaine and its adulterants (caffeine, benzocaine, lidocaine and phenacetin) in which the sensitivity (visual determination of LOD from 0.5 to 14mgmL(-1)) and the selectivity (from the study of three different eluents: CHCl3:CH3OH:HCOOHglacial (75:20:5v%), (C2H5)2O:CHCl3 (50:50v%) and CH3OH:NH4OH (100:1.5v%)) were evaluated. Aiming to improve these figures of merit, the TLC spots were identified and quantified (linearity with R(2)>0.98) by the paper spray ionization mass spectrometry (PS-MS), reaching now lower LOD values (>1.0μgmL(-1)). The method developed in this work open up perspective of enhancing the reliability of traditional and routine TLC analysis employed in the criminal expertise units. Higher sensitivity, selectivity and rapidity can be provided in forensic reports, besides the possibility of quantitative analysis. Due to the great simplicity, the PS(+)-MS technique can also be coupled directly to other separation techniques such as the paper chromatography and can still be used in analyses of LSD blotter, documents and synthetic drugs. PMID:26970868

  10. Methods of analysis-Determination of pesticides in sediment using gas chromatography/mass spectrometry

    Science.gov (United States)

    Hladik, Michelle L.; McWayne, Megan M.

    2012-01-01

    A method for the determination of 119 pesticides in environmental sediment samples is described. The method was developed by the U.S. Geological Survey (USGS) in support of the National Water Quality Assessment (NAWQA) Program. The pesticides included in this method were chosen through prior prioritization. Herbicides, insecticides, and fungicides along with degradates are included in this method and span a variety of chemical classes including, but not limited to, chloroacetanilides, organochlorines, organophosphates, pyrethroids, triazines, and triazoles. Sediment samples are extracted by using an accelerated solvent extraction system (ASE®, and the compounds of interest are separated from co-extracted matrix interferences (including sulfur) by passing the extracts through high performance liquid chromatography (HPLC) with gel-permeation chromatography (GPC) along with the use of either stacked graphitized carbon and alumina solid-phase extraction (SPE) cartridges or packed Florisil®. Chromatographic separation, detection, and quantification of the pesticides from the sediment-sample extracts are done by using gas chromatography with mass spectrometry (GC/MS). Recoveries in test sediment samples fortified at 10 micrograms per kilogram (μg/kg) dry weight ranged from 75 to 102 percent; relative standard deviations ranged from 3 to 13 percent. Method detection limits (MDLs), calculated by using U.S. Environmental Protection Agency procedures (40 CFR 136, Appendix B), ranged from 0.6 to 3.4 μg/kg dry weight.

  11. Bioassay- and liquid chromatography/mass spectrometry-guided acetylcholinesterase inhibitors from Picriafel-terrae

    Directory of Open Access Journals (Sweden)

    Lu Wen

    2013-01-01

    Full Text Available Background: Picria fel-terrae is a traditional Chinese medicine. Materials and Methods: A new approach to the search for acetylcholinesterase (AChE inhibitors from Picria fel-terrae is presented. Results: Bioassay- and LC-MS-guided fractionation of the ethyl acetate extract was from traditional Chinese medicine P.fel-terrae. Following primary extraction, the ethyl acetate extracts fraction of P.fel-terrae showed strong AChE inhibitory activities. So the sample was separated using highperformance liquid chromatography (HPLC. The effluent was split towards two identical 96-well fraction collectors, and the presence of the biologically interesting portion and chromatographic fractions could be readily detected by analyzing selected ion chromatograms through an electrophoresis-electrospray ionization mass spectrometry (ESIMS system for accurate mass measurement. One 96-well plate was used for a bioassay (AChE-inhibitory assay and detected the bioactivity and position of the relevant peak in the chromatogram. The positive well in the second 96-well plate was used for identification by LC-(+ ESIMS. Conclusion: As abovementioned, the AChE inhibitory constituents from P.fel-terrae by LC-bioassay-ESIMS were rapid identified. Liquid chromatography/ mass spectrometry (LC-MS screening detected the presence of six active compounds, identified as picfeltarraenin IA (1, picfeltarraenin IB (2, picfeltarraenin IV (3, picfeltarraenin X (4, picfeltarraenin XI (5, and one unknown compound. The structures were further determined by 13C NMR. The six compounds expressed stronger AChE inhibition than the known AChE inhibitorTacrine. Above all, the value of this LC-bioassay-ESIMS methodology is highlighted by the finding and structure elucidation of the active constituents from many other structural families of natural products.

  12. Hyphenation of supercritical fluid chromatography and two-dimensional gas chromatography-mass spectrometry for group type separations.

    Science.gov (United States)

    Potgieter, H; van der Westhuizen, R; Rohwer, E; Malan, D

    2013-06-14

    The Fischer-Tropsch (FT) process produces a variety of compounds over a wide carbon number range and the synthetic crude oil produced by this process is rich in highly valuable olefins and oxygenates, which crude oil only contains at trace levels. The characterization of these products is very challenging even when using comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC×GC-TOF-MS). The separation between cyclic paraffins and olefins is especially difficult since they elute in similar positions on the GC×GC chromatogram and since they have identical molecular masses with indistinguishable fragmentation patterns. Previously, a high performance liquid chromatography (HPLC) fractionation procedure was used prior to GC×GC-TOF-MS analysis to distinguish between alkenes and alkanes, both cyclic and non-cyclic, however, there was co-elution of the solvents used in the HPLC fractionation procedure, and the volatile components in the gasoline sample and the dilution introduced by the off-line fractionation procedure made it very difficult to investigate components present at very low concentrations. The hyphenation of supercritical fluid chromatography (SFC) to GC×GC is less complicated and the removal of the supercritical CO2 can be easily achieved without any loss of the volatile sample components, eliminating the introduction of co-eluting solvents as well as the dilution effect. This paper describes the on-line hyphenation of SFC to a GC×GC system in order to comprehensively characterize the chemical groups (saturates, unsaturates, oxygenates and aromatics) in an FT sample. PMID:23647609

  13. Determination of Hexachlorocyclohexane by Gas Chromatography Combined with Femtosecond Laser Ionization Mass Spectrometry

    Science.gov (United States)

    Yang, Xixiang; Imasaka, Tomoko; Li, Adan; Imasaka, Totaro

    2016-09-01

    Structural isomers and enantiomers of hexachlorocyclohexane (HCH) were separated using a chiral column by gas chromatography and quantitatively determined by multiphoton ionization mass spectrometry using an ultraviolet femtosecond laser (200 and 267 nm) as the ionization source. The order of elution of the enantiomers (i.e., (+)-α-HCH and (-)-α-HCH) was predicted from stabilization energies calculated for the complexes using permethylated γ-cyclodextrin as the stationary phase of the column, and the results were compared with the experimental data. The molecular ions observed for HCH were weak, even though they can be ionized through a process of resonance enhanced two-photon ionization at 200 nm. This unfavorable result can be attributed to the dissociation of the molecular ion, as predicted from quantum chemical calculations.

  14. Determination of long-chain fatty acids in serum by gas chromatography coupled to mass spectrometry

    International Nuclear Information System (INIS)

    The quantification of long-chain fatty acids is fundamental for the diagnosis of several peroxisome disorders, particularly those in which the β-oxidation peroxisome of fatty acids is affected. In this work the implementation of an analytical method for the determination of these markers in serum by gas chromatography coupled to mass spectrometry is described. Besides, samples from patients with a diagnostic impression of adrenoleukodystrophy linked to the X chromosome were analyzed. The necessary experimental conditions were achieved for the separation and quantification of C22:0, C24:0 and C26:0 fatty acids in serum, which are biochemical markers of various peroxisome diseases. The application of this method allowed confirming the diagnosis of three patients with a diagnostic impression of adrenoleukodystrophy linked to the X chromosome. The application of the method in daily practice will allow the Cuban medical system to count on a new laboratory parameter for the diagnosis of peroxisome disorders

  15. Diagnosis of propionic acidemia by gas chromatography coupled to mass spectrometry in a case analysis

    International Nuclear Information System (INIS)

    Propionic acidemia is an inherited metabolic disease caused by a deficiency in the propionyl-CoA carboxilase, a biotin-dependent mitochondrial enzyme. The disorder is a clinically heterogeneous disease and one of the most frequently occurring organic acidurias. We report the first Cuban case with a severe form of propionic acidemia followed by acidosis and death. The diagnosis was carried out by gas chromatography coupled to mass spectrometry. Our aim is to highlight the importance of organic acids urine analysis as part of the first laboratory tests in undiagnosed seriously ill children. The definitive diagnosis is important as it serves as a clear guideline to establish a suitable treatment and allows geneticists to provide patients with a proper genetic counseling

  16. Saffron authentication based on liquid chromatography high resolution tandem mass spectrometry and multivariate data analysis.

    Science.gov (United States)

    Rubert, Josep; Lacina, Ondrej; Zachariasova, Milena; Hajslova, Jana

    2016-08-01

    Saffron is one of the oldest and most expensive spices, which is often target of fraudulent activities. In this research, a new strategy of saffron authentication based on metabolic fingerprinting was developed. In the first phase, a solid liquid extraction procedure was optimized, the main aim was to isolate as maximal representation of small molecules contained in saffron as possible. In the second step, a detection method based on liquid chromatography coupled with high-resolution mass spectrometry was developed. Initially, principal component analysis (PCA) revealed clear differences between saffron cultivated and packaged in Spain, protected designation of origin (PDO), and saffron packaged in Spain of unknown origin, labeled Spanish saffron. Afterwards, orthogonal partial least square discriminant analysis (OPLS-DA) was favorably used to discriminate between Spanish saffron. The tentative identification of markers showed glycerophospholipids and their oxidized lipids were significant markers according to their origin. PMID:26988494

  17. Rapid quantification of dimethyl methylphosphonate from activated carbon particles by static headspace gas chromatography mass spectrometry.

    Science.gov (United States)

    Mitchell, Brendan L; Billingsley, Brit G; Logue, Brian A

    2013-06-01

    Activated carbon (AC) particles are utilized as an adsorbent for binding hazardous vapors in protective equipment. The binding affinity and utilization of these AC particles should be known to ensure effective and efficient use. Therefore, a simple and effective method was developed for the quantification of the chemical warfare agent simulant, dimethyl methylphosphonate (DMMP), from AC particles. Static headspace gas chromatography mass-spectrometry with internal standard, DMMP-d6, was used to perform the analysis. The method produced a linear dynamic range of 2.48-620g DMMP/kg carbon and a detection limit of 1.24g DMMP/kg carbon. Furthermore, the method produced a coefficient of variation of less than 16% for all intra- and inter-assay analyses. The method provided a simple and effective procedure for quantifying DMMP from AC particles and was applied to the analysis of a DMMP-exposed AC protective respirator filter.

  18. Indirect hydrogen analysis by gas chromatography coupled to mass spectrometry (GC-MS).

    Science.gov (United States)

    Varlet, V; Smith, F; Augsburger, M

    2013-08-01

    Gas chromatography (GC) is an analytical tool very useful to investigate the composition of gaseous mixtures. The different gases are separated by specific columns but, if hydrogen (H2 ) is present in the sample, its detection can be performed by a thermal conductivity detector or a helium ionization detector. Indeed, coupled to GC, no other detector can perform this detection except the expensive atomic emission detector. Based on the detection and analysis of H2 isotopes by low-pressure chemical ionization mass spectrometry (MS), a new method for H2 detection by GC coupled to MS with an electron ionization ion source and a quadrupole analyser is presented. The presence of H2 in a gaseous mixture could easily be put in evidence by the monitoring of the molecular ion of the protonated carrier gas. PMID:23893637

  19. The Application of Resonance-Enhanced Multiphoton Ionization Technique in Gas Chromatography Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Adan Li

    2014-01-01

    Full Text Available Gas chromatography resonance-enhanced multiphoton ionization time-of-flight mass spectrometry (GC/REMPI-TOFMS using a nanosecond laser has been applied to analyze the 16 polycyclic aromatic hydrocarbons (PAHs. The excited-state lifetime, absorption characters, and energy of electronic states of the 16 PAHs were investigated to optimize the ionization yield. A river water sample pretreated by means of solid phase extraction was analyzed to evaluate the performance of the analytical instrument. The results suggested that REMPI is superior to electron impact ionization method for soft ionization and suppresses the background signal due to aliphatic hydrocarbons. Thus, GC/REMPI-TOFMS is a more reliable method for the determination of PAHs present in the environment.

  20. Melatonin in edible plants identified by radioimmunoassay and by high performance liquid chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Melatonin, the chief hormone of the pineal gland in vertebrates, is widely distributed in the animal kingdom. Among many functions, melatonin synchronizes circadian and circannual rhythms, stimulates immune function, may increase life span, inhibits growth of cancer cells in vitro and cancer progression and promotion in vivo, and was recently shown to be a potent hydroxyl radical scavenger and antioxidant. Hydroxyl radicals are highly toxic by-products of oxygen metabolism that damage cellular DNA and other macromolecules. Herein we report that melatonin, in varying concentrations, is also found in a variety of plants. Melatonin concentrations, measured in nine different plants by radioimmunoassay, ranged from 0 to 862 pg melatonin/mg protein. The presence of melatonin was verified by gas chromatography/mass spectrometry. Our findings suggest that the consumption of plant materials that contain high levels of melatonin could alter blood melatonin levels of the indole as well as provide protection of macromolecules against oxidative damage. (au) 30 refs

  1. Confirmatory analysis of firocoxib in bovine milk by rapid resolution liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Dowling, Geraldine; Gallo, Pasquale; Regan, Liam

    2009-02-15

    A rapid method has been developed to analyse for firocoxib (FIRO) residue in bovine milk. Milk samples were extracted with acetonitrile and sample extracts were purified on Evolute ABN solid phase extraction cartridges. Aliquots were analysed by rapid resolution liquid chromatography tandem mass spectrometry (RRLC-MS/MS). The method was validated in bovine milk, according to the criteria defined in Commission Decision 2002/657/EC. The decision limit (CCalpha) was 1.18ng/mL and for the detection capability a (CCbeta) value of 2.02ng/mL was obtained. The measurement uncertainty of the method was 27%. Fortifying bovine milk samples (n=18) in three separate assays, show the accuracy of the method to be between 96 and 105%. The precision of the method, expressed as RSD values for the within-lab reproducibility at the three levels of fortification (5, 7.5 and 10ng/mL) was less than 11% respectively.

  2. Melatonin in edible plants identified by radioimmunoassay and by high performance liquid chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dubbels, R.; Klenke, E.; Schnakenberg, E.; Ehlers, C.; Schloot, W. [Univ. of Bremen, Center of Human Genetics and Genetic Counselling, Bremen (Germany); Reiter, R.J. [The Univ. of Texas Health Science Center at San Antonio, Dept. of Cellular and Structural Biology, San Antonio, Texas (United States); Goebel, A.; Schiware, H.W. [Gemeinschaftslabor Dr. Schiwara et al., Breman (Germany)

    1995-01-01

    Melatonin, the chief hormone of the pineal gland in vertebrates, is widely distributed in the animal kingdom. Among many functions, melatonin synchronizes circadian and circannual rhythms, stimulates immune function, may increase life span, inhibits growth of cancer cells in vitro and cancer progression and promotion in vivo, and was recently shown to be a potent hydroxyl radical scavenger and antioxidant. Hydroxyl radicals are highly toxic by-products of oxygen metabolism that damage cellular DNA and other macromolecules. Herein we report that melatonin, in varying concentrations, is also found in a variety of plants. Melatonin concentrations, measured in nine different plants by radioimmunoassay, ranged from 0 to 862 pg melatonin/mg protein. The presence of melatonin was verified by gas chromatography/mass spectrometry. Our findings suggest that the consumption of plant materials that contain high levels of melatonin could alter blood melatonin levels of the indole as well as provide protection of macromolecules against oxidative damage. (au) 30 refs.

  3. Liquid chromatography/coordination ion spray-mass spectrometry for the analysis of rubber vulcanization products.

    Science.gov (United States)

    Hayen, Heiko; Alvarez-Grima, M Montserrat; Debnath, Subhas C; Noordermeer, Jacques W M; Karst, Uwe

    2004-02-15

    Liquid chromatography/coordination ion spray-mass spectrometry has been used for the identification of reaction products in a model rubber vulcanization process. After LC separation using reversed-phase conditions, AgBF(4) in acetonitrile was added, and strong signals were observed for silica-rubber coupling agents and products of the reaction between these and alkenes. The method performs best for substances containing sulfur chains with chain lengths between two and eight sulfur atoms, but sulfur-free compounds containing triethoxysilyl groups were detected as well. For the latter, the postcolumn addition of NaBF(4) proved to be a suitable alternative. Besides the coupling agents, various reaction products, including sulfur-chain bridged alkenes were identified. PMID:14961739

  4. Gas chromatography-mass spectrometry analysis of various organic extracts ofMerremia borneensisfrom Sabah

    Institute of Scientific and Technical Information of China (English)

    M Amzad Hossain; Muhammad Dawood Shah; Mahyar Sakari

    2011-01-01

    Objective:To analyse the chemical composition of different extracts ofMerremia borneensis (M. borneensis) by gas chromatography-mass spectrometry (GC-MS).Methods: The dried leaves powder was extracted with methanol at room temperature by using Soxhlet extractor. Methanol crude extracts ofM. borneensis were extrastel with hexane, chloroform, ethyl acetate and butanol. Results: Qualitative analyses of various organic crude extracts showed that majority of these are flavonoids, terpeniods, alkaloids and glycosides. Most of the identified compounds by GC-MS are biologically important. Further theM. borneensisleaf possesses certain characteristics that can be ascribed to cultivation on a domestic plantation.Conclusions: The suitable extracts for respective compounds can be chosen on the basis of aboveGC-MS analysis. All the major compounds from different extracts are biologically active molecules. Thus the identification of a good number of compounds from various extractsM. borneensis might have some ecological significance.

  5. Determination of Sex Hormones in Antler Velvet by High Performance Liquid Chromatography Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    LU Chun-mei; WANG Ming-tai; MU Jun; BAI Yu-ping; DU Jian-shi; ZHANG Han-qi; WANG Jian-wei

    2012-01-01

    Eighteen sex hormones in antler velvet were determined by high performance liquid chromatography tandem mass spectrometry.The solid phase extraction was applied to eliminating the matrix effect.The experimental conditions were examined and optimized.Under the optimal conditions,the proposed method provides the good linearities and determination limits(0.2-1.0 μg/kg)of the analytes investigated.The recoveries ranging from 72.3% to 149.5% were obtained for the target analytes at two concentration levels.This method was applied to the determination of eighteen sex hormones in different kinds of antler velvet samples and the obtained results are satisfactory.The results indicate that the proposed method is suitable for the determination of sex hormones in antler velvet samples.

  6. Gas chromatography/mass spectrometry for the determination of nitrosamines in red wine.

    Science.gov (United States)

    Lona-Ramirez, Fernando J; Gonzalez-Alatorre, Guillermo; Rico-Ramírez, Vicente; Perez-Perez, Ma Cristina I; Castrejón-González, Edgar O

    2016-04-01

    N-nitrosamines (NAms) are highly active carcinogens that have been detected in food and beverages. Currently certain studies report their presence in red wine, while others fail to detect their presence. In this study the head space solid phase micro-extraction technique coupled to gas chromatography-mass spectrometry (HS-SPME-GC-MS) was applied to quantify four NAms in different types of red wine. The technique was found to be a simple, precise, fast and environmentally friendly alternative for the quantification of volatile NAms. A factorial analysis was carried out to evaluate the influence of the parameters on the HS-SPME technique. This is the first study that such analysis has been reported and where NAms in red wine have been quantified using HS-SPME-GC-MS. The method was validated by calculating the linearity, limit of detection and quantification. Two of the four NAms analyzed were found to be present in red wine samples.

  7. Enhancement of the capabilities of liquid chromatography-mass spectrometry with derivatization: general principles and applications.

    Science.gov (United States)

    Xu, Fengguo; Zou, Li; Liu, Ying; Zhang, Zunjian; Ong, Choon Nam

    2011-01-01

    The integration of liquid chromatography-mass spectrometry (LC-MS) with derivatization is a relatively new and unique strategy that could add value and could enhance the capabilities of LC-MS-based technologies. The derivatization process could be carried out in various analytical steps, for example, sampling, storage, sample preparation, HPLC separation, and MS detection. This review presents an overview of derivatization-based LC-MS strategy over the past 10 years and covers both the general principles and applications in the fields of pharmaceutical and biomedical analysis, biomarker and metabolomic research, environmental analysis, and food-safety evaluation. The underlying mechanisms and theories for derivative reagent selection are summarized and highlighted to guide future studies.

  8. Quantitative determination of medroxyprogesterone acetate in plasma by liquid chromatography/electrospray ion trap mass spectrometry.

    Science.gov (United States)

    Kim, S M; Kim, D H

    2001-01-01

    A sensitive and rapid liquid chromatography/electrospray ion trap mass spectrometry (LC/MS/MS) method has been developed for the quantitative determination of medroxyprogesterone acetate (MPA) in human plasma. Plasma samples (1.0 mL) were simply extracted with pentane and the extracts were analyzed by HPLC with the detection of the analyte in the selective reaction monitoring (SRM) mode. The determination of MPA was accurate and reproducible, with a limit of quantitation of 0.05 ng/mL in plasma. The standard calibration curve for MPA was linear (r = 0.998) over the concentration range 0.05-6.0 ng/mL in human plasma. Analysis precision over the concentration range of MPA was lower than 18.8% (relative standard deviation, RSD) and accuracy was between 96.2 and 108.7%. PMID:11675672

  9. Analysis of 5-hydroxymethylfurfural in foods by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Teixidó, E; Santos, F J; Puignou, L; Galceran, M T

    2006-11-24

    A new, simple and selective method for the analysis of 5-hydroxymethylfurfural (HMF) in foods by gas chromatography coupled to mass spectrometry (GC-MS) is proposed. Several derivatising procedures based on the formation of an HMF silylated derivative using different reagents were studied. Among the derivatising reagents examined, N,O-bis-trimethylsilyltrifluoroacetamide (BSTFA) provided the best derivatisation yield. Sample clean-up was also optimised, using either liquid-liquid extraction with dichloromethane or solid-phase extraction (SPE) with several commercially available cartridges, and the best results were obtained using ENV+ cartridges. Quality parameters such as day-to-day and run-to-run precision (RSD<10%), linearity (between 25 and 700 ng g(-1)) and detection limit (6 ng g(-1)) were established. This method was successfully applied to the analysis of HMF content in several Spanish food samples from a local market, such as jam, honey, orange juice and bakery products. PMID:17010355

  10. Characterization of volatile organic compounds by thermal desorption/gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Carbonaceous triple sorbent traps (TSTs) have been widely used to collect and concentrate volatile organic compounds (VOCs) in vapor phase samples for subsequent GC/MS analysis. Recently, this laboratory has been involved in sampling and analyzing VOCs collected from various emission sources, including headspace samples from underground storage tanks at the Department of Energy's Hanford site, in Richland, Washington. In order to evaluate the sampling adequacy and to assess any health-related impact based on the analysis results, a validated method must be employed. Therefore, the main objective of this study was to develop a methology for thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS) determination of VOCs in the vapor phase samples collected on Carbotrap C/Carbotrap/Carbosieve S III triple sorbent traps. Techniques used in method validation included VOC standard generation, thermal desorption efficiency, reproducibility of spiking on and recovery from TST, use of internal standards, detection limits determination, linearity and reproducibility of calibration

  11. Novel applications of high performance ion chromatography - inductively coupled plasma mass spectrometry (HPIC-ICP-MS)

    International Nuclear Information System (INIS)

    This work demonstrates the development of highly sensitive and selective analytical methods, which make use of the hyphenation of high performance ion chromatography (HPIC) to inductively coupled plasma sector field mass spectrometry (ICP-SFMS). On-line coupling a chromatographic separation method with an elemental detection method provides two advantages: (1) The components of a possibly interfering matrix can be separated allowing accurate and precise ultra trace analysis of the element of interest and (2) elemental species of an element can be separated and quantified. In this work, matrix separation methods for interference free determination of 232Th, 234U, 235U and 238U in geological matrices were developed and employed. Furthermore HPIC-ICP-SFMS was applied for ultra trace analysis of Pd in environmental and geological matrices. The usefulness of HPIC-ICP-SFMS for speciation studies was demonstrated by investigating the interaction of an anti-cancer drug (cisplatin) with guanosine monophosphates. (author)

  12. Determination of volatile components in cut tobacco with gas chromatography-mass spectrometry and chemometric resolution

    Institute of Scientific and Technical Information of China (English)

    HUANG Lan-fang; WU Ming-jian; SUN Xian-jun; ZHONG Ke-jun; GUO Zi-ming; DAI Yun-hui; HUANG Ke-long; GUO Fang-qiu

    2007-01-01

    Chromatography-mass spectrometry (GC-MS) was used to analyze the volatile components of cut tobacco samples with the help of heuristic evolving latent projections (HELP). After extracting with simultaneous distillation and extraction method, the volatile components in cut tobacco were detected by GC-MS. Then the obtained original two-dimensional data were resolved into pure mass spectra and chromatograms. The qualitative analysis was performed by similarity searches in the national institute of standards and technology(NIST) mass database with the obtained pure mass spectrum of each component and the quantitative results were obtained by calculating the volume of total two-way response. The accuracy of qualitative and quantitative results were greatly improved by using the two-dimensional comprehensive information of chromatograms and mass spectra. 107 of 141 separated constituents in the total ion chromatogram of the volatile components were identified and quantified, accounting for about 88.01% of the total content. The result proves that the developed method is powerful for the analysis of complex cut tobacco samples.

  13. Characterization of the fermentation process by gas chromatography Lasiodiplodia theobromae and gas chromatography coupled with mass spectrometry

    International Nuclear Information System (INIS)

    Lasiodiplodia theobromae is a fungus, which has been reported by some authors as a high yield producer of the phytohormone jasmonic acid (JA). An indigenous strain of this fungus has been used for producing a fermentation broth with a high JA concentration by the Cuban Research Institute for Sugar Cane Derivatives (ICIDCA), registered as BIOJAS. The broth has been applied to some agricultural crops and demonstrated its economic feasibility as plant growth regulator and biological control of various phytopathogenic microorganisms and pests. Both fermentation broth and biomass from this fungus contain some other metabolites having bioactive properties, for instance, fatty acids. This paper shows the composition and quantification of fatty acids in the biomass using Gas Chromatography (GC) and the identification of substances profile in fermentation broth by Gas Chromatography coupled to Mass Spectrometry (GC-MS). The most fatty acids in the biomass are palmitic, stearic, oleic, linoleic and linolenic acids, being oleic acid the major component. On the other hand, 2,32 % of fatty acid esters; 2,47 % of alkenes; 14,40 % of alcohols; 30,15 % of aldehydes and 21,73 % of paraffins were detected in the composition of fermentation broth

  14. Quantitative analysis of phenibut in rat brain tissue extracts by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Grinberga, Solveiga; Zvejniece, Liga; Liepinsh, Edgars; Dambrova, Maija; Pugovics, Osvalds

    2008-12-01

    Phenibut (3-phenyl-4-aminobutyric acid) is a gamma-aminobutyric acid mimetic drug, which is used clinically as a mood elevator and tranquilizer. In the present work, a rapid, selective and sensitive liquid chromatography-tandem mass spectrometry method for quantification of phenibut in biological matrices has been developed. The method is based on protein precipitation with acidic acetonitrile followed by isocratic chromatographic separation using acetonitrile-formic acid (0.1% in water; 8:92, v/v) mobile phase on a reversed-phase column. Detection of the analyte was performed by electrospray ionization mass spectrometry in multiple reaction monitoring mode with the precursor-to-product ion transition m/z 180.3 --> m/z 117.2. The calibration curve was linear over the concentration range 50-2000 ng/mL. The lower limit of quantification for phenibut in rat brain extracts was 50 ng/mL. Acceptable precision and accuracy were obtained over the whole concentration range. The validated method was successfully applied in a pharmacological study to analyze phenibut concentration in rat brain tissue extract samples. PMID:19034959

  15. Lipidomic profiling of dried seahorses by hydrophilic interaction chromatography coupled to mass spectrometry.

    Science.gov (United States)

    Shen, Qing; Dai, Zhiyuan; Huang, Yao-Wen; Cheung, Hon-Yeung

    2016-08-15

    Dried seahorse is a precious raw food material for cooking soups. In this study, a lipidomics strategy using the techniques of solid-phase extraction (SPE) and hydrophilic interaction chromatography-tandem mass spectrometry (HILIC-QTOF/MS) was developed for extraction, visualization, and quantification of phospholipids in dried seahorses. The parameters of SPE were optimized, and 1 mL of sample and chloroform/methanol (1:2, v/v) were found to be the best loading volume and eluting solvent, respectively. Afterwards, each phospholipid class was successfully separated on a HILIC column and analyzed by mass spectrometry. A total of 50 phospholipid molecular species were identified and determined, including 15 phosphatidylcholines (PCs), 14 phosphatidylethanolamines (PEs), 12 phosphatidylinositols (PIs) and 9 phosphatidylserines (PSs). In comparison to previously methods, this strategy was robust and efficient in extraction, characterization, and determination of phospholipids. The dried seahorse was found to contain large amounts of polyunsaturated fatty acyl phospholipids which are beneficial to human health. PMID:27006218

  16. Electrochemical oxidation of fesoterodine and identification of its oxidation products using liquid chromatography and mass spectrometry

    International Nuclear Information System (INIS)

    The electrochemical behavior of fesoterodine (FES), an antimuscarinic drug used for the treatment of urge incontinence and overactive bladder, was investigated using linear sweep and cyclic voltammetry at a stationary and rotating disc glassy carbon electrodes. A single two-electron anodic signal of FES was observed in neutral buffered aqueous methanolic solutions. Kinetics of alkaline hydrolysis of FES to its active metabolite 5-hydroxymethyl tolterodine was investigated by time dependent linear sweep voltammetry. Controlled potential electrolysis of FES solutions was performed at platinum gauze electrode in aqueous-methanolic media. Electrolyzed solutions were analyzed using ultra performance liquid chromatography with electrospray ionization quadrupole time-of-flight mass spectrometry. Two main products of electrochemical oxidation of fesoterodine were identified as 5-formyl fesoterodine (isobutyric acid 2-(3-diisopropylamino-1-phenyl-propyl)-4-formyl-phenyl ester) and N-desisopropylated fesoterodine (isobutyric acid 4-hydroxymethyl-2-(3-isopropylamino-1-phenyl-propyl)-phenyl ester). The mechanism of the electrochemical oxidation of FES has been proposed and confirmed using on-line electrochemistry/mass spectrometry with porous glassy carbon electrode

  17. Rapid Preconcentration for Liquid Chromatography-Mass Spectrometry Assay of Trace Level Neuropeptides

    Science.gov (United States)

    Zhou, Ying; Mabrouk, Omar S.; Kennedy, Robert T.

    2013-11-01

    Measurement of neuropeptides in the brain through in vivo microdialysis sampling provides direct correlation between neuropeptide concentration and brain function. Capillary liquid chromatography-multistage mass spectrometry (CLC-MSn) has proven to be effective at measuring endogenous neuropeptides in microdialysis samples. In the method, microliter samples are concentrated onto nanoliter volume packed beds before ionization and mass spectrometry analysis. The long times required for extensive preconcentration present a barrier to routine use because of the many samples that must be analyzed and instability of neuropeptides. In this study, we evaluated the capacity of 75 μm inner diameter (i.d.) capillary column packed with 10 μm reversed phase particles for increasing the throughput in CLC-MSn based neuropeptide measurement. Coupling a high injection flow rate for fast sample loading/desalting with a low elution flow rate to maintain detection sensitivity, this column has reduced analysis time from ˜30 min to 3.8 min for 5 μL sample, with 3 pM limit of detection (LOD) for enkephalins and 10 pM LOD for dynorphin A1-8 in 5 μL sample. The use of isotope-labeled internal standard lowered peptide signal variation to less than 5 %. This method was validated for in vivo detection of Leu and Met enkephalin with microdialysate collected from rat globus pallidus. The improvement in speed and stability makes CLC-MSn measurement of neuropeptides in vivo more practical.

  18. Quantitative analysis of tivantinib in rat plasma using ultra performance liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Bai, Yan-Li; Yuan, Hong-Chang; Zhang, Dong-Tao; Liu, Yuan; Zhang, Yin

    2016-07-15

    In this work, a simple, sensitive and fast ultra performance liquid chromatography with tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the quantitative determination of tivantinib in rat plasma. Plasma samples were processed with a protein precipitation. The separation was achieved by an Acquity UPLC BEH C18 (2.1mm×50mm, 1.7μm) column with a gradient mobile phase consisting of 0.1% formic acid in water and acetonitrile. Detection was carried out using positive-ion electrospray tandem mass spectrometry via multiple reaction monitoring (MRM). The validated method had an excellent linearity in the range of 1.0-100ng/mL (r(2)>0.9967) with a lower limit of quantification (1.0ng/mL). The extraction recovery was in the range of 79.4-84.2% for tivantinib and 80.3% for carbamazepine (internal standard, IS). The intra- and inter-day precision was below 8.9% and accuracy was from -7.2% to 9.5%. No notable matrix effect and astaticism was observed for tivantinib. The method has been successfully applied to a pharmacokinetic study of tivantinib in rats for the first time, which provides the basis for the further development and application of tivantinib. PMID:27179187

  19. An improved method for measuring metaldehyde in surface water using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Schumacher, Melanie; Castle, Glenn; Gravell, Anthony; Mills, Graham A; Fones, Gary R

    2016-01-01

    The molluscicide metaldehyde (2,4,6,8-tetramethyl-1,3,5,7-tetraoxocanemetacetaldehyde) is an emerging pollutant. It is frequently detected in surface waters, often above the European Community Drinking Water Directive limit of 0.1 μg/L for a single pesticide. Gas chromatography mass spectrometry (GC-MS) can be used to determine metaldehyde in environmental waters, but this method requires time consuming extraction techniques prior to instrumental analysis. Use of liquid chromatography-tandem mass spectrometry (LC-MS/MS) can overcome this problem. We describe a novel LC-MS/MS method, using a methylamine mobile phase additive, coupled with on-line sample enrichment that allows for the rapid and sensitive measurement of metaldehyde in surface water. Only the methylamine adduct of metaldehyde was formed with other unwanted alkali metal adducts and dimers being suppressed. As considerably less collision energy is required to fragment the methylamine adduct, a five-fold improvement in method sensitivity, compared to a previous method using an ammonium acetate buffer mobile phase was achieved. This new approach offers: •A validated method that meets regulatory requirements for the determination of metaldehyde in surface water.•Improved reliability of quantification over existing LC-MS/MS methods by using stable precursor ions for multiple reaction monitoring.•Low limits of quantification for tap water (4 ng/L) and river water (20 ng/L) using only 800 μL of sample; recoveries > 97%. PMID:27054094

  20. Analysis of pesticides by gas chromatography/multiphoton ionization/mass spectrometry using a femtosecond laser

    International Nuclear Information System (INIS)

    Highlights: → Gas chromatography/multiphoton ionization/time-of-flight mass spectrometry was utilized for analysis. → A standard mixture sample containing 49 pesticides and 4 real samples were measured. → Third-harmonic emission of a Ti:sapphire laser (100 fs) was employed as an ionization source. → Most of the pesticides were softly ionized by the femtosecond laser. → Three pesticides were found, although some of them were not detected by GC/EI/MS-MS. - Abstract: Gas chromatography/multiphoton ionization/time-of-flight mass spectrometry (GC/MPI/TOFMS) was utilized for analysis of a standard mixture sample containing 49 pesticides and 4 real samples using the third-harmonic emission (267 nm) of a femtosecond Ti:sapphire laser (100 fs) as the ionization source. A sample of a standard mixture of n-alkane was also measured for calibration of the retention time indices of the pesticides. Two photons are required for the excitation of n-alkane due to an absorption band located in the far ultraviolet region (140 nm). The n-alkane molecule in the excited state was subsequently ionized either directly or by absorbing another photon because of a high ionization potential. Due to a large excess of energy, the molecular ion was decomposed and formed many fragment ions. Compared to n-alkanes, most of the pesticides were softly ionized by the femtosecond laser; one photon was used for excitation and another was used for the subsequent ionization. The pesticides with no conjugated double bond had a lower ionization efficiency. The present analytical instrument was applied to several samples prepared from a variety of vegetables and a single fruit after pretreatment with solid-phase extraction. Three pesticides were found in these samples, although some of them were not detected by conventional GC/EI/MS-MS due to insufficient sensitivity and selectivity.

  1. Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Douglas C., E-mail: douglas.baxter@alsglobal.com [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Faarinen, Mikko [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Osterlund, Helene; Rodushkin, Ilia [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Division of Geosciences, Lulea University of Technology, 977 87 Lulea (Sweden); Christensen, Morten [ALS Scandinavia AB, Maskinvaegen 2, 183 53 Taeby (Sweden)

    2011-09-09

    Highlights: {center_dot} We determine methylmercury in serum and plasma using isotope dilution calibration. {center_dot} Separation by gas chromatography and detection by inductively coupled plasma mass spectrometry. {center_dot} Data for 50 specimens provides first reference range for methylmercury in serum. {center_dot} Serum samples shown to be stable for 11 months in refrigerator. - Abstract: A method for the determination of methylmercury in plasma and serum samples was developed. The method uses isotope dilution with {sup 198}Hg-labeled methylmercury, extraction into dichloromethane, back-extraction into water, aqueous-phase ethylation, purge and trap collection, thermal desorption, separation by gas chromatography, and mercury isotope specific detection by inductively coupled plasma mass spectrometry. By spiking 2 mL sample with 1.2 ng tracer, measurements in a concentration interval of (0.007-2.9) {mu}g L{sup -1} could be performed with uncertainty amplification factors <2. A limit of quantification of 0.03 {mu}g L{sup -1} was estimated at 10 times the standard deviation of concentrations measured in preparation blanks. Within- and between-run relative standard deviations were <10% at added concentration levels of 0.14 {mu}g L{sup -1}, 0.35 {mu}g L{sup -1} and 2.8 {mu}g L{sup -1}, with recoveries in the range 82-110%. Application of the method to 50 plasma/serum samples yielded a median (mean; range) concentration of methylmercury of 0.081 (0.091; <0.03-0.19) {mu}g L{sup -1}. This is the first time methylmercury has been directly measured in this kind of specimen, and is therefore the first estimate of a reference range.

  2. Analysis of paralytic shellfish toxins using high-field asymmetric waveform ion mobility spectrometry with liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Beach, Daniel G; Melanson, Jeremy E; Purves, Randy W

    2015-03-01

    The analysis of paralytic shellfish toxins (PSTs) by liquid chromatography-mass spectrometry remains a challenge because of their high polarity, large number of analogues and the complex matrix in which they occur. Here we investigate the potential utility of high-field asymmetric waveform ion mobility spectrometry (FAIMS) as a gas-phase ion separation tool for analysis of PSTs by mass spectrometry. We investigate the separation of PSTs using FAIMS with two divergent goals: using FAIMS as a primary separation tool for rapid screening by electrospray ionization (ESI)-FAIMS-MS or combined with LC in a multidimensional LC-ESI-FAIMS-MS separation. First, a survey of the parameters that affect the sensitivity and selectivity of PST analysis by FAIMS was carried out using ESI-FAIMS-MS. In particular, the use of acetonitrile as a gas additive in the carrier gas flow offered good separation of all PST epimeric pairs. A second set of FAIMS conditions was also identified, which focussed PSTs to a relatively narrow CV range allowing development of an LC-ESI-FAIMS-MS method for analysis of PST toxins in complex mussel tissue extracts. The quantitative capabilities of this method were evaluated by analysing a PST containing mussel tissue matrix material. Results compared favourably with analysis by an established LC-post-column oxidation-fluorescence method with recoveries ranging from 70 to 106%, although sensitivity was somewhat reduced. The current work represents the first successful separation of PST isomers using ion mobility and shows the promise of FAIMS as a tool for analysis of algal biotoxins in complex samples and outlines some critical requirements for its future improvement.

  3. Americium and plutonium separation by extraction chromatography for determination by accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kazi, Zakir H. [Department of Earth Science, University of Ottawa, 140 Louis Pasteur Avenue, Ottawa K1N 6N5 (Canada); Cornett, Jack R., E-mail: jack.cornett@uottawa.ca [Department of Earth Science, University of Ottawa, 140 Louis Pasteur Avenue, Ottawa K1N 6N5 (Canada); Zhao, Xaiolei; Kieser, Liam [Department of Physics, University of Ottawa, 140 Louis Pasteur Avenue, Ottawa K1N 6N5 (Canada)

    2014-06-01

    Highlights: • Am and Pu were adsorbed and separated using a single extraction chromatography DGA column. • Pu was eluted from the column completely using on-column reduction of Pu(IV) to Pu(III). • ²⁴¹Am and 239,240Pu measurements by accelerator mass spectrometry (AMS) agree with the certified values in two SRMs. Abstract: A simple method was developed to separate Pu and Am using single column extraction chromatography employing N,N,N',N'-tetra-n-octyldiglycolamide (DGA) resin. Isotope dilution measurements of Am and Pu were performed using accelerator mass spectrometry (AMS) and alpha spectrometry. For maximum adsorption Pu was stabilized in the tetra valent oxidation state in 8 M HNO₃ with 0.05 M NaNO₂ before loading the sample onto the resin. Am(III) was adsorbed also onto the resin from concentrated HNO₃, and desorbed with 0.1 M HCl while keeping the Pu adsorbed. The on-column reduction of Pu(IV) to Pu(III) with 0.02 M TiCl₃ facilitated the complete desorption of Pu. Interferences (e.g. Ca²⁺, Fe³⁺) were washed off from the resin bed with excess HNO₃. Using NdF₃, micro-precipitates of the separated isotopes were prepared for analysis by both AMS and alpha spectrometry. The recovery was 97.7 ± 5.3% and 95.5 ± 4.6% for ²⁴¹Am and ²⁴²Pu respectively in reagents without a matrix. The recoveries of the same isotopes were 99.1 ± 6.0 and 96.8 ± 5.3% respectively in garden soil. The robustness of the method was validated using certified reference materials (IAEA 384 and IAEA 385). The measurements agree with the certified values over a range of about 1–100 Bq kg⁻¹. The single column separation of Pu and Am saves reagents, separation time, and cost.

  4. Profiling of lipid species by normal-phase liquid chromatography, nanoelectrospray ionization, and ion trap-orbitrap mass spectrometry

    DEFF Research Database (Denmark)

    Sokol, Elena; Almeida, Reinaldo; Hannibal-Bach, Hans Kristian;

    2013-01-01

    chromatography-Fourier transform mass spectrometry (LC-FTMS) and LC-ITMS(2) (ion trap tandem mass spectrometry) for profiling and structural analysis of lipid species. The workflow uses a normal-phase LC system for efficient separation of apolar and polar lipid species combined with sensitive and specific...... analysis powered by a chip-based nanoelectrospray ion source and a hybrid ion trap-orbitrap mass spectrometer. The workflow was executed using a primary LC-FTMS survey routine for identification and profiling of lipid species based on high-mass accuracy and retention time followed by a targeted LC-ITMS(2...

  5. Determination of Tetracycline Antibiotic Residues in Edible Swine Tissues by Liquid Chromatography with Spectrofluorometric Detection and Confirmation by Mass Spectrometry

    OpenAIRE

    Pena, Angelina; Lino, Celeste M.; Alonso, Rosa; BARCELÓ Damia

    2007-01-01

    A sensitive and specific method is described for the simultaneous determination of oxytetracycline, tetracycline (TC), and chlortetracycline residues in edible swine tissues, by combining liquid chromatography with spectrofluorometric and mass spectrometry detection. The procedure involved a preliminary extraction with EDTA-McIlvaine buffer acidified at pH 4.0, followed by solid-phase extraction cleanup using a polymeric sorbent. The liquid chromatography analysis was performed with spectrofl...

  6. A Liquid Chromatography–Mass Spectrometry/Mass Spectrometry Method for the Quantification of Cefixime in Human Plasma

    Directory of Open Access Journals (Sweden)

    R Arunkumar

    2013-06-01

    Full Text Available Cefixime is a third generation cephalosporin effective against gram-positive and gram-negative organisms. It is available in solid and liquid oral dosages of 100 mg, 200 mg and 400 mg. It is used to treat respiratory and urinary tract infections. In this study, a liquid chromatography-Mass spectrometric method to quantify cefixime in human plasma was developed. The quantification range for the method was 114.5033 to 9374.2050 ng/ml and the method was validated as per US FDA standards for pharmaceutical development. Cephalexin was used as the internal standard. Chromatographic and mass spectrometric conditions and extraction procedures were optimized to quantify the levels of cefixime in human plasma accurately. 100 μL of K3EDTA human plasma was required for sample processing. Extraction of cefixime and cephalexin was done by Liquid-Liquid extraction and separation was achieved by reverse phase liquid chromatography. Specificity, selectivity, matrix effect, calibration curve, precision, accuracy, ruggedness, recovery, stability and dilution integrity were established for cefixime in human plasma. The method met acceptance criteria for all the validation parameters and can be successfully applied to human pharmacokinetic and bioequivalence studies of cefixime. The bioanalytical method was highly sensitive and selective for estimation of cefixime in human plasma samples containing the drug

  7. Determination of polar pesticides in olive oil and olives by hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry and high resolution mass spectrometry.

    Science.gov (United States)

    Nortes-Méndez, Rocío; Robles-Molina, José; López-Blanco, Rafael; Vass, Andrea; Molina-Díaz, Antonio; Garcia-Reyes, Juan F

    2016-09-01

    This article reports the development of two HPLC-MS methods for the determination of polar pesticides in olive oil and olive samples by hydrophilic interaction liquid chromatography (HILIC) separation followed by mass spectrometry detection with tandem mass spectrometry using a triple quadrupole instrument operated in multiple reaction monitoring mode (HILIC-MS/MS) or electrospray time-of-flight mass spectrometry (HILIC-TOFMS). The selected polar pesticides included in the study were: amitrol, cyromazine, diquat, paraquat, mepiquat, trimethylsulfonium (trimesium, glyphosate counterion) and fosetyl aluminium. The simple sample treatment procedure was based on liquid partitioning with methanol. The performance of the sample extraction was evaluated in terms of recovery rates and matrix effects in both olive oil and olives matrices. The results obtained for olive oil were satisfactory while, due to the high complexity of olives, poor recovery rates were obtained for the extraction of diquat, paraquat and amitrol, although with a reasonable precision enabling its use in routine analysis. Similarly, matrix effects were minor in the case of olive oil (ca. 20% suppression average), while significantly higher suppression was observed for olives (30-50% suppression average). The studied approaches were found to be useful for the determination of the pesticides studied in olive oil and olives with limits of quantitation below 5µgkg(-1) in most cases when tandem mass spectrometry was used, thus being in compliance with MRLs set by current EU regulation. PMID:27343599

  8. Determination of polar pesticides in olive oil and olives by hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry and high resolution mass spectrometry.

    Science.gov (United States)

    Nortes-Méndez, Rocío; Robles-Molina, José; López-Blanco, Rafael; Vass, Andrea; Molina-Díaz, Antonio; Garcia-Reyes, Juan F

    2016-09-01

    This article reports the development of two HPLC-MS methods for the determination of polar pesticides in olive oil and olive samples by hydrophilic interaction liquid chromatography (HILIC) separation followed by mass spectrometry detection with tandem mass spectrometry using a triple quadrupole instrument operated in multiple reaction monitoring mode (HILIC-MS/MS) or electrospray time-of-flight mass spectrometry (HILIC-TOFMS). The selected polar pesticides included in the study were: amitrol, cyromazine, diquat, paraquat, mepiquat, trimethylsulfonium (trimesium, glyphosate counterion) and fosetyl aluminium. The simple sample treatment procedure was based on liquid partitioning with methanol. The performance of the sample extraction was evaluated in terms of recovery rates and matrix effects in both olive oil and olives matrices. The results obtained for olive oil were satisfactory while, due to the high complexity of olives, poor recovery rates were obtained for the extraction of diquat, paraquat and amitrol, although with a reasonable precision enabling its use in routine analysis. Similarly, matrix effects were minor in the case of olive oil (ca. 20% suppression average), while significantly higher suppression was observed for olives (30-50% suppression average). The studied approaches were found to be useful for the determination of the pesticides studied in olive oil and olives with limits of quantitation below 5µgkg(-1) in most cases when tandem mass spectrometry was used, thus being in compliance with MRLs set by current EU regulation.

  9. Hyphenated and comprehensive liquid chromatography × gas chromatography-mass spectrometry for the identification of Mycobacterium tuberculosis.

    Science.gov (United States)

    Mourão, Marta P B; Denekamp, Ilse; Kuijper, Sjoukje; Kolk, Arend H J; Janssen, Hans-Gerd

    2016-03-25

    Tuberculosis is one of the world's most emerging public health problems, particularly in developing countries. Chromatography based methods have been used to tackle this epidemic by focusing on biomarker detection. Unfortunately, interferences from lipids in the sputum matrix, particularly cholesterol, adversely affect the identification and detection of the marker compounds. The present contribution describes the serial combination of normal phase liquid chromatography (NPLC) with thermally assisted hydrolysis and methylation followed by gas chromatography-mass spectrometry (THM-GC-MS) to overcome the difficulties of biomarker evaluation. The in-series combination consists of an LC analysis where fractions are collected and then transferred to the THM-GC-MS system. This was either done with comprehensive coupling, transferring all the fractions, or with hyphenated interfacing, i.e. off-line multi heart-cutting, transferring only selected fractions. Owing to the high sensitivity and selectivity of LC as a sample pre-treatment method, and to the high specificity of the MS as a detector, this analytical approach, NPLC × THM-GC-MS, is extremely sensitive. The results obtained indicate that this analytical set-up is able to detect down to 1 × 10(3) mycobacteria/mL of Mycobacterium tuberculosis strain 124, spiked in blank sputum samples. It is a powerful analytical tool and also has great potential for full automation. If further studies demonstrate its usefulness when applied blind in real sputum specimens, this technique could compete with the current smear microscopy in the early diagnosis of tuberculosis. PMID:26585206

  10. Semi-targeted analysis of metabolites using capillary-flow ion chromatography coupled to high-resolution mass spectrometry.

    Science.gov (United States)

    Burgess, Karl; Creek, Darren; Dewsbury, Paul; Cook, Ken; Barrett, Michael P

    2011-11-30

    This work describes a novel application of capillary-flow ion chromatography mass spectrometry for metabolomic analysis, and comparison of the technique to octadecyl silica and hydrophilic interaction chromatography (HILIC)-based mass spectrometry. While liquid chromatography/mass spectrometry (LC/MS) is rapidly becoming the standard technique for metabolomic analysis, metabolomic samples are extremely heterogeneous, leading to a requirement for multiple methods of analysis and separation techniques to perform a 'global' metabolomic analysis. While C18 is suitable for hydrophobic metabolites and has been used extensively in pharmaceutical drug metabolism studies, HILIC is, in general, efficient at separating polar metabolites. Phosphorylated species and organic acids are challenging to analyse and effectively quantitate on both systems. There is therefore a requirement for an MS-compatible analytical technique that can separate negatively charged compounds, such as ion-exchange chromatography. Evaluation of capillary flow ion chromatography with electrolytic suppression was performed on a library of metabolite standards and was shown to effectively separate organic acids and sugar di- and tri-phosphates. Limits of detection for these compounds range from 0.01 to 100 pmol on-column. Application of capillary ion chromatography to a comparative analysis of energy metabolism in procyclic forms of the parasitic protozoan Trypanosoma brucei where cells were grown on glucose or proline as a carbon source was demonstrated to be more effective than HILIC for detection of the organic acids that comprise glucose central metabolism and the tricarboxylic acid (TCA) cycle.

  11. Liquid chromatography tandem mass spectrometry for measuring ¹³C-labeling in intermediates of the glycolysis and pentose phosphate pathway.

    Science.gov (United States)

    Cocuron, Jean-Christophe; Alonso, Ana Paula

    2014-01-01

    This chapter describes a procedure to analyze (13)C-labeled phosphorylated compounds by liquid chromatography tandem mass spectrometry. Phosphorylated compounds, intermediaries of the glycolysis and pentose phosphate pathway, are separated by anion exchange chromatography and their isotopic labeling is determined by mass spectrometry. A sensitivity in the fmole range is achieved using scheduled multiple reaction monitoring mode.

  12. Screening for estrogen residues in calf urine: Comparison of a validated yeast estrogen bioassay and gas chromatography-tandem mass spectrometry

    NARCIS (Netherlands)

    Nielen, M.W.F.; Bovee, T.F.H.; Heskamp, H.H.; Lasaroms, J.J.P.; Sanders, M.B.; Rhijn, van J.A.; Groot, M.J.; Hoogenboom, L.A.P.

    2006-01-01

    Within the European Union, the control for residues of illegal hormones in food-producing animals is based on urine analysis for a few target analytes using gas chromatography/mass spectrometry and/or liquid chromatography¿tandem mass spectrometry. Recently, we developed a robust yeast bioassay scre

  13. Elucidation and identification of amino acid containing membrane lipids using liquid chromatography/high-resolution mass spectrometry

    NARCIS (Netherlands)

    Moore, E.K.; Hopmans, E.C.; Rijpstra, W.I.C.; Villanueva, L.; Sinninghe Damste, J.S.

    2016-01-01

    RATIONALE: Intact polar lipids (IPLs) are the building blocks of cell membranes, and amino acid containing IPLs havebeen observed to be involved in response to changing environmental conditions in various species of bacteri a. High-performance liquid chromatography/mass spectrometry (HPLC/MS) has be

  14. ANALYSIS OF TRACE-LEVEL ORGANIC COMBUSTION PROCESS EMISSIONS USING NOVEL MULTIDIMENSIONAL GAS CHROMATOGRAPHY-MASS SPECTROMETRY PROCEDURES

    Science.gov (United States)

    The paper discusses the analysis of trace-level organic combustion process emissions using novel multidimensional gas chromatography-mass spectrometry (MDGC-MS) procedures. It outlines the application of the technique through the analyses of various incinerator effluent and produ...

  15. Molecular analysis of intact preen waxes of Calidris canutus (Aves : Scolopacidae) by gas chromatography/mass spectrometry

    NARCIS (Netherlands)

    Dekker, MHA; Piersma, T; Damste, JSS; Dekker, Marlèn H.A.; Sinninghe Damsté, Jaap S.

    2000-01-01

    The intact preen wax esters of the red knot Calidris canutus were studied with gas chromatography/mass spectrometry (GC/MS) and GC/MS/MS. In this latter technique, transitions from the molecular ion to fragment ions representing the fatty acid moiety of the wax esters were measured, providing additi

  16. Advantages of Atmospheric Pressure Chemical Ionization in Gas Chromatography Tandem Mass Spectrometry: Pyrethroid Insecticides as a Case Study

    NARCIS (Netherlands)

    Portolés, T.; Mol, J.G.J.; Sancho, J.V.; Hernández, F.

    2012-01-01

    Gas chromatography coupled to mass spectrometry (GC/MS) has been extensively applied for determination of volatile, nonpolar, compounds in many applied fields like food safety, environment, or toxicology. The wide majority of methods reported use electron ionization (EI), which may result in extensi

  17. Accurate quantitation of pentaerythritol tetranitrate and its degradation products using liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry

    NARCIS (Netherlands)

    Brust, H.; Asten, A. van; Koeberg, M.; Dalmolen, J.; Heijden, A.E.D.M. van der; Schoenmakers, P.

    2014-01-01

    After an explosion of pentaerythritol tetranitrate (PETN), its degradation products pentaerythritol trinitrate (PETriN), dinitrate (PEDiN) and mononitrate (PEMN) were detected using liquid chromatography-atmospheric-pressure chemical-ionization-mass spectrometry (LC-APCI-MS). Discrimination between

  18. Introducing Students to Gas Chromatography-Mass Spectrometry Analysis and Determination of Kerosene Components in a Complex Mixture

    Science.gov (United States)

    Pacot, Giselle Mae M.; Lee, Lyn May; Chin, Sung-Tong; Marriott, Philip J.

    2016-01-01

    Gas chromatography-mass spectrometry (GC-MS) and GC-tandem MS (GC-MS/MS) are useful in many separation and characterization procedures. GC-MS is now a common tool in industry and research, and increasingly, GC-MS/MS is applied to the measurement of trace components in complex mixtures. This report describes an upper-level undergraduate experiment…

  19. Simultaneous determination of estrogens and progestogens in honey using high performance liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    This work describes the development and validation of a method for the simultaneous determination of 13 estrogens and progestogens in honey by high performance liquid chromatography-tandem mass spectrometry. The target compounds were preconcentrated by solid phase extraction. Pretreatment variables ...

  20. High performance liquid chromatography-mass spectrometry analysis of high antioxidant australian fruits with antiproliferative activity against cancer cells

    Directory of Open Access Journals (Sweden)

    Joseph Sirdaarta

    2016-01-01

    Abbreviations used: DPPH: di (phenyl- (2,4,6-trinitrophenyl iminoazanium, HPLC: High-performance liquid chromatography, IC50: The concentration required to inhibit by 50%, LC50: The concentration required to achieve 50% mortality, MS: Mass spectrometry. Ian Edwin Cock

  1. Hydrophilic interaction chromatography-mass spectrometry for anionic metabolic profiling of urine from antibiotic-treated rats

    NARCIS (Netherlands)

    Kok, Miranda G M; Swann, Jonathan R; Wilson, Ian D; Somsen, Govert W; de Jong, Gerhardus J

    2014-01-01

    Hydrophilic interaction chromatography-mass spectrometry (HILIC-MS) was used for anionic metabolic profiling of urine from antibiotic-treated rats to study microbial-host co-metabolism. Rats were treated with the antibiotics penicillin G and streptomycin sulfate for four or eight days and compared t

  2. Determination of the brominated flame retardant, hexabroomcyclodocane in sediments and biota by liquid chromatography-electrospray ionization mass spectrometry

    NARCIS (Netherlands)

    Morris, S.; Bersuder, P.; Allchin, C.R.; Zegers, B.; Boon, J.P.; Leonards, P.E.G.; Boer, de J.

    2006-01-01

    A method involving reversed-phase, liquid chromatography coupled to electrospray ionisation mass spectrometry (LC-ESI-MS) was developed for separation, detection and quantitation of the alpha-, beta- and gamma-diastereoisomers of hexabromocyclododecane (HBCD). To address the lack of environmental da

  3. THE DETERMINATION OF DELTA-5-ANDROSTENEDIOL AND ITS SULFATE IN SERUM AND URINE BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY

    NARCIS (Netherlands)

    DIKKESCHEI, LD; WOLTHERS, BG; WILLEMSE, PHB; VANDERPOL, H; DERUYTERBUITENHUIS, AW; NAGEL, GT

    1993-01-01

    OBJECTIVES We developed an assay for delta-5-androstenediol (adiol) and delta-5-androstenediol-3-sulphate (adiol-3S) in serum and adiol and total adiol sulphate (adiol-S) in urine. DESIGN An analytical procedure using HPLC and gas chromatography-mass spectrometry was devised and tested for its relia

  4. Determination of kava lactones in food supplements by liquid chromatography-atmospheric pressure chemical ionisation tandem mass spectrometry

    NARCIS (Netherlands)

    Bobeldijk, I.; Boonzaaijer, G.; Spies-Faber, E.J.; Vaes, W.H.J.

    2005-01-01

    Reversed-phase liquid chromatography and detection with atmospheric pressure chemical ionisation tandem mass spectrometry was used for the determination of kava extracts in herbal mixtures. One percent of kava extract can be detected, corresponding to approximately 0.05-0.2 mg/g of the individual ka

  5. ANALYSIS OF ARTEMISININ AND RELATED SESQUITERPENOIDS FROM ARTEMISIA-ANNUA L BY COMBINED GAS-CHROMATOGRAPHY MASS-SPECTROMETRY

    NARCIS (Netherlands)

    WOERDENBAG, HJ; PRAS, N; BOS, R; VISSER, JF; HENDRIKS, H; MALINGRE, TM

    1991-01-01

    The sesquiterpenoid artemisinin (3) and its biosynthetic precursors arteannuic acid (1), arteannuin B (2) and artemisitene (4) can be separated and identified by combined gas chromatography/mass spectrometry both as a mixture of reference standards as well as in extracts of Artemisia annua L. From t

  6. Direct detection of Mycobacterium tuberculosis in sputum using combined solid phase extraction-gas chromatography-mass spectrometry

    NARCIS (Netherlands)

    N.A. Dang; M. Mourão; S. Kuijper; E. Walters; H.-G. Janssen; A.H.J. Kolk

    2015-01-01

    Recently, thermally-assisted hydrolysis and methylation followed by gas chromatography-mass spectrometry (THM-GC-MS) in combination with chemometrics has been used to develop a 20-compound model for fast differentiation of Mycobacterium tuberculosis (MTB) from Non-tuberculous mycobacteria (NTM) in b

  7. Direct analysis of intact glycidyl fatty acid esters in edible oils using gas chromatography-mass spectrometry

    NARCIS (Netherlands)

    H. van Steenbergen; K. Hrnčiřík; A. Ermacora; S. de Koning; H.-G. Janssen

    2013-01-01

    Glycidyl esters (GE), fatty acid esters of glycidol, are process contaminants formed during edible oil processing. A novel direct method for the determination of intact GE in oils and fats based on gas chromatography-mass spectrometry (GC-MS) is presented. The method consists of a simple extraction

  8. Confirmation of synthetic glucocorticoids with liquid chromatography/mass spectrometry: Organization and results of an international interlaboratory comparison test

    NARCIS (Netherlands)

    Hauwe, O. van den; Campbell, K.; Crooks, S.R.H.; Schilt, R.; Peteghem, C.H. van

    2005-01-01

    Within the framework of a European Union (EU) research project entitled "Food Safety Screening: Synthetic Glucocorticoids (QLK1-1999-00122)," an international interlaboratory ring test was organized to compare and evaluate different liquid chromatography/mass spectrometry (LC/MS) confirmatory method

  9. Determination of BROMATE AT PARTS-PER-TRILLION LEVELS BY GAS CHROMATOGRAPHY-MASS SPECTROMETRY WITH NEGATIVE CHEMICAL IONIZATION

    Science.gov (United States)

    The ozonation of bromide-containing source waters produces bromate as a class 2B carcinogenic disinfection by-product. The present work describes the determination of bromate by gas chromatography-negative chemical ionization mass spectrometry (GC-NCIMS) following a bromate react...

  10. Liquid chromatography-tandem mass spectrometry assay for the quantification of free and total sialic acid in human cerebrospinal fluid.

    NARCIS (Netherlands)

    Ham, M. van der; Koning, T.J. de; Lefeber, D.J.; Fleer, A.; Prinsen, B.H.; Sain-van der Velden, M.G. de

    2010-01-01

    BACKGROUND: Analysis of sialic acid (SA) metabolites in cerebrospinal fluid (CSF) is important for clinical diagnosis. In the present study, a high-performance liquid chromatography-tandem mass spectrometry (HPLC/MS/MS) method for free sialic acid (FSA) and total sialic acid (TSA) in human CSF was v

  11. An Advanced Analytical Chemistry Experiment Using Gas Chromatography-Mass Spectrometry, MATLAB, and Chemometrics to Predict Biodiesel Blend Percent Composition

    Science.gov (United States)

    Pierce, Karisa M.; Schale, Stephen P.; Le, Trang M.; Larson, Joel C.

    2011-01-01

    We present a laboratory experiment for an advanced analytical chemistry course where we first focus on the chemometric technique partial least-squares (PLS) analysis applied to one-dimensional (1D) total-ion-current gas chromatography-mass spectrometry (GC-TIC) separations of biodiesel blends. Then, we focus on n-way PLS (n-PLS) applied to…

  12. An Undergraduate Experiment for the Measurement of Perfluorinated Surfactants in Fish Liver by Liquid Chromatography-Tandem Mass Spectrometry

    Science.gov (United States)

    Stock, Naomi L.; Martin, Jonathan W.; Ye, Yun; Mabury, Scott A.

    2007-01-01

    A laboratory experiment that provides students a hands-on introduction to the specific techniques of liquid chromatography-tandem mass spectrometry (LC-MS/MS) and electrospray ionization is presented. The students can thus practice the analytical principles of sample extraction, detection, quantification, and quality control using a fresh fish…

  13. A high expression EGFR/cell membrane chromatography and online high performance liquid chromatography/mass spectrometry method for screening EGFR antagonists from Rhizoma Polygoni Cuspidati

    OpenAIRE

    Meng Sun; Yan-min Zhang; Jie Zhang; Si-cen Wang; Lang-chong He

    2011-01-01

    The epidermal growth factor receptors (EGFRs) in some tumor cells are significant targets for drug discovery. In this work, we have developed an EGFR cell membrane chromatography and online high performance liquid chromatography/mass spectrometry system for screening active component from Rhizoma Polygoni Cuspidati. As a result, resveratrol from Rhizoma Polygoni Cuspidati was found to be the active component acting on EGFR like gefitinib. There was a good relationship between their inhibiting...

  14. Profiling the substitution pattern of xyloglucan derivatives by integrated enzymatic hydrolysis, hydrophilic-interaction liquid chromatography and mass spectrometry.

    Science.gov (United States)

    Liu, Jun; Kisonen, Victor; Willför, Stefan; Xu, Chunlin; Vilaplana, Francisco

    2016-09-01

    Plant polysaccharides constitute arguably the most complex family of biomacromolecules in terms of the stereochemistry and regiochemistry of their intramolecular linkages. The chemical modification of such polysaccharides introduces an additional level of complexity for structural determinations. We have developed an integrated analytical procedure combining selective enzymatic hydrolysis, hydrophilic interaction liquid chromatography (HILIC), and mass spectrometry (MS) to describe the substitution pattern of xyloglucan (XyG) and its chemo-enzymatic derivatives (cationic, anionic, and benzyl aminated). Enzymatic hydrolysis of XyG derivatives by a xyloglucan-specific endoglucanase (XEG) generates oligosaccharides amenable for mass spectrometric identification with distinct structures, based on enzymatic substrate recognition and hydrolytic pattern. Matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-ToF-MS) and electrospray ionisation mass spectrometry (ESI-MS) offer qualitative mass profiling of the chemical derivatives. Separation and identification of the complex oligosaccharide profiles released by enzymatic hydrolysis is achieved by hyphenation of hydrophilic interaction liquid chromatography with mass spectrometry (HILIC-ESI-MS). Further fragmentation by tandem mass spectrometry (ESI-MS/MS) in positive mode enables the structural sequencing of modified XyG oligosaccharides and the identification of the substituent position without further derivatisation. This integrated approach can be used to obtain semi-quantitative information of the substitution pattern of hemicellulose derivatives, with fundamental implications for their modification mechanisms and performance. PMID:27524300

  15. Fast separation of triterpenoid saponins using supercritical fluid chromatography coupled with single quadrupole mass spectrometry.

    Science.gov (United States)

    Huang, Yang; Zhang, Tingting; Zhou, Haibo; Feng, Ying; Fan, Chunlin; Chen, Weijia; Crommen, Jacques; Jiang, Zhengjin

    2016-03-20

    Triterpenoid saponins (TSs) are the most important components of some traditional Chinese medicines (TCMs) and have exhibited valuable pharmacological properties. In this study, a rapid and efficient method was developed for the separation of kudinosides, stauntosides and ginsenosides using supercritical fluid chromatography coupled with single quadrupole mass spectrometry (SFC-MS). The separation conditions for the selected TSs were carefully optimized after the initial screening of eight stationary phases. The best compromise for all compounds in terms of chromatographic performance and MS sensitivity was obtained when water (5-10%) and formic acid (0.05%) were added to the supercritical carbon dioxide/MeOH mobile phase. Beside the composition of the mobile phase, the nature of the make-up solvent for interfacing SFC with MS was also evaluated. Compared to reversed phase liquid chromatography, the SFC approach showed higher resolution and shorter running time. The developed SFC-MS methods were successfully applied to the separation and identification of TSs present in Ilex latifolia Thunb., Panax quinquefolius L. and Panax ginseng C.A. Meyer. These results suggest that this SFC-MS approach could be employed as a useful tool for the quality assessment of natural products containing TSs as active components. PMID:26773536

  16. Thin-Layer Chromatography/Desorption Electrospray Ionization Mass Spectrometry: Investigation of Goldenseal Alkaloids

    Energy Technology Data Exchange (ETDEWEB)

    Van Berkel, Gary J [ORNL; Tomkins, Bruce A [ORNL; Kertesz, Vilmos [ORNL

    2007-01-01

    Desorption electrospray ionization mass spectrometry was investigated as a means to qualitatively identify and to quantify analytes directly from developed normal-phase thin layer chromatography plates. The atmospheric sampling capillary of a commercial ion trap mass spectrometer was extended to permit sampling and ionization of analytes in bands separated on intact TLC plates (up to 10 cm x 10 cm). A surface positioning software package and the appropriate hardware enabled computer-controlled surface scanning along the length of development lanes or at fixed RF value across the plates versus the stationary desorption electrospray emitter. Goldenseal (Hydrastis canadensis) and related alkaloids and commercial dietary supplements were used as standards and samples. Alkaloid standards and samples were spotted and separated on aluminum- or glass-backed plates using established literature methods. The mass spectral signal levels as a function of desorption spray solvent were investigated with acetonitrile proving superior to methanol. The detection levels (ca. 5 ng each or 14 -28 pmol) in mass spectral full scan mode were determined statistically from the calibration curves (2.5 - 100 pmol) for the standards berberine, palmatine and hydrastinine spotted as a mixture and separated on the plates. Qualitative screening of the major alkaloids present in six different over-the-counter "goldenseal" dietary supplements was accomplished by obtaining full scan mass spectra during surface scans along the development lane in the direction of increasing RF value. In one sample, alkaloids were detected that strongly suggested the presence of at least one additional herb undeclared on the product label. These same data indicated the misidentification of one of the alkaloids in the TLC literature. Quantities of the alkaloids present in two of the samples determined using the mass spectral data were in reasonable agreement with the label values indicating the quantitative ability of

  17. Rhamnolipid biosurfactant analysis using online turbulent flow chromatography-liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Behrens, Beate; Helmer, Patrick O; Tiso, Till; Blank, Lars M; Hayen, Heiko

    2016-09-23

    Rhamnolipids are biosurfactants produced by a variety of bacterial species that present a promising alternative to surfactants from petrochemical or oleochemical origin. The success of the fermentation is evaluated by subsequent qualitative and quantitative analysis. However, the sample preparation for high numbers of samples is often laborious and inefficient. In this study an online sample preparation is developed for the qualitative and quantitative analysis of rhamnolipids by LC-MS/MS. Online sample preparation is carried out on a TurboFlow Cyclone MAX column using turbulent flow chromatography. Sample preparation prior the analysis is minimized to a dilution and syringe filtration step leading to an instrumental analysis time of 33min. The limit of detection and the limit of quantification were 0.4ng and 0.6ng on column, respectively. Recovery of the main mono- and di-rhamnolipids from a fermentation sample was 102-104%. Additionally, the rhamnolipid biosynthetic precursors 3-hydroxy(alkanoyloxy)alkanoic acids (HAAs) are covered, albeit extraction is not quantitative (85-90%). The analysis of rhamnolipids from four different microbial species was in good agreement with previous reports. The presented method allows rapid and comprehensive analysis of rhamnolipids with minimal sample preparation directly from the fermentation broth. The application of complementary data-dependent MS/MS acquisition enables non-target screening of rhamnolipids. PMID:27567141

  18. Rhamnolipid biosurfactant analysis using online turbulent flow chromatography-liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Behrens, Beate; Helmer, Patrick O; Tiso, Till; Blank, Lars M; Hayen, Heiko

    2016-09-23

    Rhamnolipids are biosurfactants produced by a variety of bacterial species that present a promising alternative to surfactants from petrochemical or oleochemical origin. The success of the fermentation is evaluated by subsequent qualitative and quantitative analysis. However, the sample preparation for high numbers of samples is often laborious and inefficient. In this study an online sample preparation is developed for the qualitative and quantitative analysis of rhamnolipids by LC-MS/MS. Online sample preparation is carried out on a TurboFlow Cyclone MAX column using turbulent flow chromatography. Sample preparation prior the analysis is minimized to a dilution and syringe filtration step leading to an instrumental analysis time of 33min. The limit of detection and the limit of quantification were 0.4ng and 0.6ng on column, respectively. Recovery of the main mono- and di-rhamnolipids from a fermentation sample was 102-104%. Additionally, the rhamnolipid biosynthetic precursors 3-hydroxy(alkanoyloxy)alkanoic acids (HAAs) are covered, albeit extraction is not quantitative (85-90%). The analysis of rhamnolipids from four different microbial species was in good agreement with previous reports. The presented method allows rapid and comprehensive analysis of rhamnolipids with minimal sample preparation directly from the fermentation broth. The application of complementary data-dependent MS/MS acquisition enables non-target screening of rhamnolipids.

  19. Determination of O6-butylguanine in DNA by immunoaffinity extraction/gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    A sensitive, specific, and rapid method for quantitating the minor adduct O6-butylguanine (O6BuG) in hydrolyzed DNA has been developed by combining immunoaffinity chromatography and high resolution gas chromatography-negative ion chemical ionization-mass spectrometry. Polyclonal antibodies raised against O6BuG were coupled to CNBr-activated Sepharose 4B and used for sample clean-up and extraction of the specific O6-alkylguanine. After addition of O6BuG and its deuterium labeled analogue (O6BuG-D7), used as internal standard, hydrolyzed DNA was applied on the immunoaffinity column and washed with water, and the immunoadsorbed butylated guanines were eluted with acetone/water cetome/water (95/5) before gas chromatographic derivatization. O6BuG and O6BuG-D7 were analyzed and quantitated by high resolution gas chromatography-negative ion chemical ionization-mass spectrometry as their pentafluorobenzyl-trimethylsilyl derivatives. Immunoaffinity column capacity and O6BuG recovery from this column were 1.53 nmol O6BuG/column and 62 +/- 5%, respectively. The method was applied to evaluate O6BuG levels in DNA butylated in vitro with 10 mM N-nitroso-Nr-butylurea or isolated from rats given an i.p. dose of 185 mg/kg N-nitroso-N-butylurea or N-nitrosodibutylamine. In the first case the level of modifications present in calf thymus DNA was 104 mumol O6BuG/mol guanine, and in the second case O6BuG in liver DNA was about 6 times higher after N-nitroso-N-butylurea (2.11 mumol O6BuG/mol guanine) than after N-nitrosodibutylamine (0.34 mumol O6BuG/mol guanine) treatment. These results indicate that O6BuG formed in vivo can be isolated and quantitated by this method, which may also be useful for studying DNA damage and repair mechanisms

  20. Identification of forced degradation products of tamsulosin using liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Namdev, Deepak; Borkar, Roshan M; Raju, B; Kalariya, Pradipbhai D; Rahangdale, Vinodkumar T; Gananadhamu, S; Srinivas, R

    2014-01-01

    A rapid and gradient high-performance liquid chromatography combined with quadrupole time-of-flight electrospray ionization tandem mass spectrometry (LC/Q-TOF-ESI-MS/MS) method has been developed for the identification and structural characterization of stressed degradation products of tamsulosin. Tamsulosin, a selective α1-adrenoceptor antagonist, was subjected to forced degradation studies under hydrolytic (acid, base and neutral), oxidative, photolytic and thermal stress conditions as per ICH guidelines Q1A (R2). The drug degraded significantly under hydrolytic (base and neutral), thermal, oxidative and photolytic conditions, while it was stable to acid hydrolytic stress conditions. A total of twelve degradation products were formed and the chromatographic separation of the drug and its degradation products were achieved on a GRACE C-18 column (250mm×4.6mm, 5μm). All the degradants have been identified and characterized by LC/ESI-MS/MS and accurate mass measurements. To elucidate the structures of degradation products, fragmentation of the [M+H](+) ions of tamsulosin and its degradation products was studied by using LC-MS/MS experiments combined with accurate mass measurements. The product ions of all the protonated degradation products were compared with the product ions of protonated tamsulosin to assign most probable structures for the observed degradation products. PMID:24083958

  1. Analysis of psilocybin and psilocin in Psilocybe subcubensis Guzmán by ion mobility spectrometry and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Keller, T; Schneider, A; Regenscheit, P; Dirnhofer, R; Rücker, T; Jaspers, J; Kisser, W

    1999-01-11

    A new method has been developed for the rapid analysis of psilocybin and/or psilocin in fungus material using ion mobility spectrometry. Quantitative analysis was performed by gas chromatography-mass spectrometry after a simple one-step extraction involving homogenization of the dried fruit bodies of fungi in chloroform and derivatization with MSTFA. The proposed methods resulted in rapid procedures useful in analyzing psychotropic fungi for psilocybin and psilocin.

  2. Screening for multiple classes of marine biotoxins by liquid chromatography-high-resolution mass spectrometry.

    Science.gov (United States)

    Blay, Pearl; Hui, Joseph P M; Chang, James; Melanson, Jeremy E

    2011-04-01

    Marine biotoxins pose a significant food safety risk when bioaccumulated in shellfish, and adequate testing for biotoxins in shellfish is required to ensure public safety and long-term viability of commercial shellfish markets. This report describes the use of a benchtop Orbitrap system for liquid chromatography-mass spectrometry (LC-MS) screening of multiple classes of biotoxins commonly found in shellfish. Lipophilic toxins such as dinophysistoxins, pectenotoxins, and azaspiracids were separated by reversed phase LC in less than 7 min prior to MS data acquisition at 2 Hz with alternating positive and negative scans. This approach resulted in mass accuracy for analytes detected in positive mode (gymnodimine, 13-desmethyl spirolide C, pectenotoxin-2, and azaspiracid-1, -2, and -3) of less than 1 ppm, while those analytes detected in negative mode (yessotoxin, okadaic acid, and dinophysistoxin-1 and -2) exhibited mass errors between 2 and 4 ppm. Hydrophilic toxins such as domoic acid, saxitoxin, and gonyautoxins were separated by hydrophilic interaction LC (HILIC) in less than 4 min, and MS data was collected at 1 Hz in positive mode, yielding mass accuracy of less than 1 ppm error at a resolving power of 100,000 for the analytes studied (m/z 300-500). Data were processed by extracting 5 ppm mass windows centered around the calculated masses of the analytes. Limits of detection (LOD) for the lipophilic toxins ranged from 0.041 to 0.10 μg/L (parts per billion) for the positive ions, 1.6-5.1 μg/L for those detected in negative mode, while the domoic acid and paralytic shellfish toxins yielded LODs ranging from 3.4 to 14 μg/L. Toxins were detected in mussel tissue extracts free of interference in all cases.

  3. Characterization of Arsenic Biotransformation Products from an Open Anaerobic Degradation of Fucus distichus by Hydride Generation Gas Chromatography Atomic Absorption Spectrometry and High Performance Liquid Chromatography Inductively Coupled Plasma Mass Spectrometry

    OpenAIRE

    Abiodun A. Ojo; Onasanya, Amos

    2013-01-01

    This work reports on the isolation and determination of biotransformation products obtained from the organoarsenic compounds that are present in Fucus distichus when it was subjected to an open anaerobic decomposition by using the Hydride Generation Gas Chromatography Atomic Absorption Spectrometry (HG-GC-AAS) and High Performance Liquid Chromatography Inductively Coupled Plasma Mass Spectrometry (HPLC-ICP-MS). The seaweed and filtrate residues obtained from the open anaerobic degradation pro...

  4. Americium and plutonium separation by extraction chromatography for determination by accelerator mass spectrometry.

    Science.gov (United States)

    Kazi, Zakir H; Cornett, Jack R; Zhao, Xaiolei; Kieser, Liam

    2014-06-01

    A simple method was developed to separate Pu and Am using single column extraction chromatography employing N,N,N',N'-tetra-n-octyldiglycolamide (DGA) resin. Isotope dilution measurements of Am and Pu were performed using accelerator mass spectrometry (AMS) and alpha spectrometry. For maximum adsorption Pu was stabilized in the tetra valent oxidation state in 8M HNO3 with 0.05 M NaNO2 before loading the sample onto the resin. Am(III) was adsorbed also onto the resin from concentrated HNO3, and desorbed with 0.1 M HCl while keeping the Pu adsorbed. The on-column reduction of Pu(IV) to Pu(III) with 0.02 M TiCl3 facilitated the complete desorption of Pu. Interferences (e.g. Ca(2+), Fe(3+)) were washed off from the resin bed with excess HNO3. Using NdF3, micro-precipitates of the separated isotopes were prepared for analysis by both AMS and alpha spectrometry. The recovery was 97.7±5.3% and 95.5±4.6% for (241)Am and (242)Pu respectively in reagents without a matrix. The recoveries of the same isotopes were 99.1±6.0 and 96.8±5.3% respectively in garden soil. The robustness of the method was validated using certified reference materials (IAEA 384 and IAEA 385). The measurements agree with the certified values over a range of about 1-100 Bq kg(-1). The single column separation of Pu and Am saves reagents, separation time, and cost. PMID:24856406

  5. Determination of alkyl amines in atmospheric aerosol particles: a comparison of gas chromatography-mass spectrometry and ion chromatography approaches

    Directory of Open Access Journals (Sweden)

    R.-J. Huang

    2014-03-01

    Full Text Available In recent years low molecular weight alkyl amines have been recognized to play an important role in particle formation and growth in the lower atmosphere. However, major uncertainties are associated with their atmospheric processes, sources and sinks, mostly due to the lack of ambient measurements and the difficulties in accurate quantification of alkyl amines at trace level. In this study, we present the evaluation and optimization of two analytical approaches, i.e., gas chromatography-mass spectrometry (GC-MS and ion chromatography (IC, for the determination of alkyl amines in aerosol particles. Alkyl amines were converted to carbamates through derivatization with isobutyl chloroformate for GC-MS determination. A set of parameters affecting the analytical performances of the GC-MS approach, including reagent amount, reaction time and pH value, was evaluated and optimized. The accuracy is 84.3–99.1%, and the limits of detection obtained are 1.8–3.9 pg. For the IC approach, a solid phase extraction (SPE column was used to separate alkyl amines from interfering cations before IC analysis. 1–2% (v/v of acetone (or 2–4% (v/v of acetonitrile was added to the eluent to improve the separation of alkyl amines on the IC column. The limits of detection obtained are 2.1–15.9 ng and the accuracy is 55.1–103.4%. The lower accuracy can be attributed to evaporation losses of amines during the sample concentration procedure. Measurements of ambient aerosol particle samples collected in Hong Kong show that the GC-MS approach is superior to the IC approach for the quantification of primary and secondary alkyl amines due to its lower detection limits and higher accuracy.

  6. Analysis of odour compounds from scented consumer products using gas chromatography-mass spectrometry and gas chromatography-olfactometry.

    Science.gov (United States)

    Bartsch, Jennifer; Uhde, Erik; Salthammer, Tunga

    2016-01-21

    Scented consumer products are being bought in increasing amounts and gaining more popularity. There is, however, relatively little information available about their ingredients, emissions and allergenic potential. Frequently, a mixture of different fragrance substances and not solely an individual substance contributes to the overall desired smell. The aim of this study was to investigate the odorous volatile organic compounds (OVOCs) in consumer products containing fragrances. Over 44 products were selected: various scented candles, printing products with different scent types and other products types particularly meant to be used indoors. Measurements were carried out in a desiccator. Air samples were collected on thermal desorption tubes to determine the released fragrance substances by means of gas chromatography-mass spectrometry (GC-MS). Moreover, gas chromatography-olfactometry (GC-O) was used to obtain sensory data and to ensure no important odorant was overlooked. Using both methods it was possible to distinguish between odour active and inactive compounds and subsequently to identify almost 300 different odorants across all scented products. Besides the advantage of differentiation, as the human nose is a very sensitive detector, GC-O was found to be a useful tool for detecting traces and chosen target compounds. One focus in this study lay on the 26 EU-regulated fragrance allergens to prove their relevance in scented consumer goods. In total, 18 of them were identified, with at least one substance being present in almost every product. Benzyl alcohol, cinnamaldehyde, citronellol, eugenol, linalool and limonene were the prevalently detected allergens. Particularly linalool and limonene were observed in over 50% of the products. In addition, eugenol appeared to be one of the most frequently detected compounds in trace-level concentrations in the candle emissions.

  7. Analysis of daphnane orthoesters in poisonous Australian pimelea species by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Chow, Sharon; Fletcher, Mary T; McKenzie, Ross A

    2010-06-23

    Cattle grazing in arid rangelands of Australia suffer periodic extensive and serious poisoning by the plant species Pimelea trichostachya, P. simplex, and P. elongata. Pimelea poisoning (also known as St. George disease and Marree disease) has been attributed to the presence of the diterpenoid orthoester simplexin in these species. However, literature relating to previous studies is complicated by taxonomic revisions, and the presence of simplexin has not previously been verified in all currently recognized taxa capable of inducing pimelea poisoning syndrome, with no previous chemical studies of P. trichostachya (as currently classified) or P. simplex subsp. continua. We report here the isolation of simplexin from P. trichostachya and the development of a liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) method to measure simplexin concentrations in pimelea plant material. Simplexin was quantified by positive-ion atmospheric pressure chemical ionization (APCI) LC-MS/MS with selected reaction monitoring (SRM) of the m/z 533.3 > 253.3 transition. LC-MS/MS analysis of the four poisonous taxa P. trichostachya, P. elongata, P. simplex subsp. continua, and P. simplex subsp. simplex showed similar profiles with simplexin as the major diterpenoid ester component in all four taxa accompanied by varying amounts of related orthoesters. Similar analyses of P. decora, P. haematostachya, and P. microcephala also demonstrated the presence of simplexin in these species but at far lower concentrations, consistent with the limited reports of stock poisoning associated with these species. The less common, shrubby species P. penicillaris contained simplexin at up to 55 mg/kg dry weight and would be expected to cause poisoning if animals consumed sufficient plant material.

  8. [Determination of aflatoxins in cereals and oils by liquid chromatography-triple quadrupole tandem mass spectrometry].

    Science.gov (United States)

    Wang, Xiupin; Li, Peiwu; Yang, Yang; Zhang, Wen; Zhang, Qi; Fan, Sufang; Yu, Li; Wang, Lin; Chen, Xiaomei; Li, Ying; Jiang, Jun

    2011-06-01

    The high performance liquid chromatography (HPLC)-triple quadrupole tandem mass spectrometry was applied for the determination of the aflatoxins: B1 (AFB1), B2 (AFB2), G1 (AFG1) and G2 (AFG2), in cereals and oils. The samples were first extracted by ultrasonic method. The optimized conditions of ultrasonic extraction were as follows: temperature of 50 degrees C, extraction time of 3 min, methanol-water (containing 40 g/L NaCl) (80: 20, v/v) solution as the medium and a ratio of sample to solvent of 1 : 3 (g: mL). The extracts were then purified using an immunoaffinity column. The separation was performed on a C18 column with mobile phases of 10 mmol/L ammonium acetate and methanol in gradient elution. The sensitive detection of the four AFT compounds by electrospray ionization mass spectrometry (ESI-MS) was carried out in selected reaction monitoring (SRM) mode with aflatoxin M1 (AFM1) as the internal standard. Under the optimized conditions, the limits of detection of AFB1, AFB2, AFG1 and AFG2 were 0.002, 0.004, 0.004 and 0.012 microg/kg, respectively. The recoveries of aflatoxins in different spiked cereals and oils were in the range from 87% to 111%. The intra-day and inter-day precisions were not more than 6.7% and 5.6%, respectively. In comparison with the external standard method, this method can effectively inhibit the matrix effects, and greatly improve the accuracy.

  9. [Determination of aflatoxins in cashew by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Bi, Ruifeng; Fan, Zhixian; Fu, Meng

    2011-12-01

    A method for the determination of four aflatoxins in cashew using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed. The sample was extracted with methanol-water (8: 2, v/v) solution, followed by a cleanup procedure with Florisil column. The target compounds were eluted using 5 mL acetone-water-formic acid (96: 3.5:0.5, v/v/v) solution. The eluate was dried under N2, then dissolved in 1 mL methanol. Four aflatoxins were separated in MG C18 column (100 mm x 3.0 mm, 3 microm) adopting a gradient program within 15 min. A triple quadrupole mass spectrometry equipped with an electrospray ionization source operated in the positive ion mode was used to detect the aflatoxins. The good correlation coefficients (r2 > 0.997) of the four aflatoxins were obtained within their respective linear ranges. The limits of detection (S/N = 3) were between 0.009 microg/kg and 0.04 microg/kg, and the limits of quantification (S/N = 10) were between 0.03 microg/kg and 0.12 microg/kg. The recoveries were in a range of 63.0% -78.5% with the relative standard deviations (RSDs) varied from 2.8% to 9.1%. The validation results meet the requirements of trace assay. Matrix effects were estimated and the signal suppression/enhancement ranged from 88.8% to 99.4%. The results indicate that the developed method is simple, fast, accurate, and can be applied for the determination of fours aflatoxins in cashew.

  10. [Determination of aflatoxins in cereals and oils by liquid chromatography-triple quadrupole tandem mass spectrometry].

    Science.gov (United States)

    Wang, Xiupin; Li, Peiwu; Yang, Yang; Zhang, Wen; Zhang, Qi; Fan, Sufang; Yu, Li; Wang, Lin; Chen, Xiaomei; Li, Ying; Jiang, Jun

    2011-06-01

    The high performance liquid chromatography (HPLC)-triple quadrupole tandem mass spectrometry was applied for the determination of the aflatoxins: B1 (AFB1), B2 (AFB2), G1 (AFG1) and G2 (AFG2), in cereals and oils. The samples were first extracted by ultrasonic method. The optimized conditions of ultrasonic extraction were as follows: temperature of 50 degrees C, extraction time of 3 min, methanol-water (containing 40 g/L NaCl) (80: 20, v/v) solution as the medium and a ratio of sample to solvent of 1 : 3 (g: mL). The extracts were then purified using an immunoaffinity column. The separation was performed on a C18 column with mobile phases of 10 mmol/L ammonium acetate and methanol in gradient elution. The sensitive detection of the four AFT compounds by electrospray ionization mass spectrometry (ESI-MS) was carried out in selected reaction monitoring (SRM) mode with aflatoxin M1 (AFM1) as the internal standard. Under the optimized conditions, the limits of detection of AFB1, AFB2, AFG1 and AFG2 were 0.002, 0.004, 0.004 and 0.012 microg/kg, respectively. The recoveries of aflatoxins in different spiked cereals and oils were in the range from 87% to 111%. The intra-day and inter-day precisions were not more than 6.7% and 5.6%, respectively. In comparison with the external standard method, this method can effectively inhibit the matrix effects, and greatly improve the accuracy. PMID:22032163

  11. An empirical Bayes model using a competition score for metabolite identification in gas chromatography mass spectrometry

    Directory of Open Access Journals (Sweden)

    Kim Seongho

    2011-10-01

    Full Text Available Abstract Background Mass spectrometry (MS based metabolite profiling has been increasingly popular for scientific and biomedical studies, primarily due to recent technological development such as comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GCxGC/TOF-MS. Nevertheless, the identifications of metabolites from complex samples are subject to errors. Statistical/computational approaches to improve the accuracy of the identifications and false positive estimate are in great need. We propose an empirical Bayes model which accounts for a competing score in addition to the similarity score to tackle this problem. The competition score characterizes the propensity of a candidate metabolite of being matched to some spectrum based on the metabolite's similarity score with other spectra in the library searched against. The competition score allows the model to properly assess the evidence on the presence/absence status of a metabolite based on whether or not the metabolite is matched to some sample spectrum. Results With a mixture of metabolite standards, we demonstrated that our method has better identification accuracy than other four existing methods. Moreover, our method has reliable false discovery rate estimate. We also applied our method to the data collected from the plasma of a rat and identified some metabolites from the plasma under the control of false discovery rate. Conclusions We developed an empirical Bayes model for metabolite identification and validated the method through a mixture of metabolite standards and rat plasma. The results show that our hierarchical model improves identification accuracy as compared with methods that do not structurally model the involved variables. The improvement in identification accuracy is likely to facilitate downstream analysis such as peak alignment and biomarker identification. Raw data and result matrices can be found at http

  12. Advances on the compositional analysis of glycosphingolipids combining thin-layer chromatography with mass spectrometry.

    Science.gov (United States)

    Müthing, Johannes; Distler, Ute

    2010-01-01

    Glycosphingolipids (GSLs), composed of a hydrophilic carbohydrate chain and a lipophilic ceramide anchor, play pivotal roles in countless biological processes, including infectious diseases and the development of cancer. Knowledge of the number and sequence of monosaccharides and their anomeric configuration and linkage type, which make up the principal items of the glyco code of biologically active carbohydrate chains, is essential for exploring the function of GSLs. As part of the investigation of the vertebrate glycome, GSL analysis is undergoing rapid expansion owing to the application of novel biochemical and biophysical technologies. Mass spectrometry (MS) takes part in the network of collaborations to further unravel structural and functional aspects within the fascinating world of GSLs with the ultimate aim to better define their role in human health and disease. However, a single-method analytical MS technique without supporting tools is limited yielding only partial structural information. Because of its superior resolving power, robustness, and easy handling, high-performance thin-layer chromatography (TLC) is widely used as an invaluable tool in GSL analysis. The intention of this review is to give an insight into current advances obtained by coupling supplementary techniques such as TLC and mass spectrometry. A retrospective view of the development of this concept and the recent improvements by merging (1) TLC separation of GSLs, (2) their detection with oligosaccharide-specific proteins, and (3) in situ MS analysis of protein-detected GSLs directly on the TLC plate, are provided. The procedure works on a nanogram scale and was successfully applied to the identification of cancer-associated GSLs in several types of human tumors. The combination of these two supplementary techniques opens new doors by delivering specific structural information of trace quantities of GSLs with only limited investment in sample preparation. PMID:19609886

  13. Advances in liquid chromatography-high-resolution mass spectrometry for quantitative and qualitative environmental analysis.

    Science.gov (United States)

    Aceña, Jaume; Stampachiacchiere, Serena; Pérez, Sandra; Barceló, Damià

    2015-08-01

    This review summarizes the advances in environmental analysis by liquid chromatography-high-resolution mass spectrometry (LC-HRMS) during the last decade and discusses different aspects of their application. LC-HRMS has become a powerful tool for simultaneous quantitative and qualitative analysis of organic pollutants, enabling their quantitation and the search for metabolites and transformation products or the detection of unknown compounds. LC-HRMS provides more information than low-resolution (LR) MS for each sample because it can accurately determine the mass of the molecular ion and its fragment ions if it can be used for MS-MS. Another advantage is that the data can be processed using either target analysis, suspect screening, retrospective analysis, or non-target screening. With the growing popularity and acceptance of HRMS analysis, current guidelines for compound confirmation need to be revised for quantitative and qualitative purposes. Furthermore, new commercial software and user-built libraries are required to mine data in an efficient and comprehensive way. The scope of this critical review is not to provide a comprehensive overview of the many studies performed with LC-HRMS in the field of environmental analysis, but to reveal its advantages and limitations using different workflows. PMID:26138893

  14. Determination of omeprazole and its metabolites in human plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Kanazawa, Hideko; Okada, Akiko; Matsushima, Yoshikazu; Yokota, Hiromitsu; Okubo, Shigeo; Mashige, Fumiko; Nakahara, Kazuhiko

    2002-03-01

    Omeprazole is a benzimidazole compound that acts as a proton-pump inhibitor. Because the metabolism of omeprazole is mainly catalyzed by cytochrome P-450 (CYP) 3A4 and CYP2C19. the genetic polymorphism of CYP2C19 could be of clinical concern in the treatment of acid-related diseases with omeprazole. Therefore, a reliable method for omeprazole phenotyping is desirable in clinical situations. This study has demonstrated the determination of omeprazole and its metabolites in human plasma by liquid chromatography-three-dimensional quadrupole mass spectrometry with a sonic spray ionization interface. The analytical column was YMC-Pack Pro C18(50x2.0 mm I.D.) using acetonitrile-50 mM ammonium acetate (pH 7.25) (1:4) at a flow-rate of 0.2 ml/min. The drift voltage was 30 V. The sampling aperture was heated at 110 degrees C and Shield temperature was 230 degrees C. In the mass spectrum, the molecular ions of omeprazole, hydroxyomeprazole and omeprazole sulfone were clearly observed as base peaks. This method is sufficiently sensitive and accurate for pharmacokinetic studies of omeprazol. PMID:11999727

  15. Liquid chromatography/tandem mass spectrometry assay for the quantification of troxerutin in human plasma.

    Science.gov (United States)

    Liu, Fei; Xu, Yu; Rui, Lei; Gao, Shu; Dong, Haijun; Guo, Qingxiang

    2006-01-01

    A simple, rapid, sensitive and specific liquid chromatography/tandem mass spectrometry method was developed and validated to quantify troxerutin in human plasma. The analyte and rutin, used as the internal standard, were analyzed on a Phenomenex Synergi Fusion RP column interfaced with a triple-quadrupole tandem mass spectrometer using positive electrospray ionization. Acetonitrile/water (20:80 v/v) was used as the isocratic mobile phase, with 0.1% formic acid in water. A simple sample preparation method of protein precipitation with perchloric acid was employed. The assay was linear over the concentration range 31.25-4000 pg/mL. Correlation coefficients generated by linear regression with a 1/x(2) weighting factor ranged from 0.9991 to 0.9996. The intra- and inter-day precision over the entire concentration range were less than 12.28%. The method was successfully applied to a pharmacokinetic study after oral administration of a 300 mg troxerutin drop pill to 18 healthy volunteers.

  16. Drug screening of whole blood by ultra-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Oiestad, Elisabeth Leere; Johansen, Unni; Oiestad, Ase Marit Leere; Christophersen, Asbjørg Solberg

    2011-06-01

    An ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method for screening of drugs in whole blood has been developed and validated. Samples were prepared by supported liquid-liquid extraction on ChemElute(®) columns with ethyl acetate/heptane (4:1). LC separation was achieved with an Acquity HSS T3-column (2.1 100 mm, 1.8-μm particle). Mass detection was performed by positive ion mode electrospray MS-MS and included the following drugs/metabolites: morphine, codeine, ethyl morphine, oxycodone, buprenorphine, methadone, cocaine, methylphenidate, amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA), Δ(9)-tetrahydrocannabinol (THC), fentanyl, alprazolam, bromazepam, clonazepam, diazepam, nordiazepam, 3-OH-diazepam, fenazepam, flunitrazepam, lorazepam, nitrazepam, oxazepam, zopiclone, zolpidem, carisoprodol, and meprobamate. The cycle time was 9 min, and within- and between-day relative coefficients of variation varied from 1% to 33% and 2% to 58%, respectively. Extraction recoveries from whole blood were > 50% except for morphine and THC. The limit of quantitation was 0.1 to 521 ng/mL, depending on the drug. PMID:21619723

  17. Molecular Ionization-Desorption Analysis Source (MIDAS) for Mass Spectrometry: Thin-Layer Chromatography

    Science.gov (United States)

    Winter, Gregory T.; Wilhide, Joshua A.; LaCourse, William R.

    2016-02-01

    Molecular ionization-desorption analysis source (MIDAS), which is a desorption atmospheric pressure chemical ionization (DAPCI) type source, for mass spectrometry has been developed as a multi-functional platform for the direct sampling of surfaces. In this article, its utility for the analysis of thin-layer chromatography (TLC) plates is highlighted. Amino acids, which are difficult to visualize without staining reagents or charring, were detected and identified directly from a TLC plate. To demonstrate the full potential of MIDAS, all active ingredients from an analgesic tablet, separated on a TLC plate, were successfully detected using both positive and negative ion modes. The identity of each of the compounds was confirmed from their mass spectra and compared against standards. Post separation, the chemical signal (blue permanent marker) as reference marks placed at the origin and solvent front were used to calculate retention factor (Rf) values from the resulting ion chromatogram. The quantitative capabilities of the device were exhibited by scanning caffeine spots on a TLC plate of increasing sample amount. A linear curve based on peak are, R2 = 0.994, was generated for seven spots ranging from 50 to 1000 ng of caffeine per spot.

  18. Liquid chromatography-tandem mass spectrometry for analysis of intestinal permeability of loperamide in physiological buffer.

    Directory of Open Access Journals (Sweden)

    Miriam S Rubelt

    Full Text Available Analysis of in vitro samples with high salt concentrations represents a major challenge for fast and specific quantification with liquid chromatography-tandem mass spectrometry (LC-MS/MS. To investigate the intestinal permeability of opioids in vitro employing the Ussing chamber technique, we developed and validated a fast, sensitive and selective method based on LC-MS/MS for the determination of loperamide in HEPES-buffered Ringer's solution. Chromatographic separation was achieved with an Atlantis dC18 column, 2.1 mm×20 mm, 3 µm particle size and a gradient consisting of methanol/0.1% formic acid and ammonium acetate. The flow rate was 0.7 ml/min, and the total run time was 3 min. For quantification, two mass transitions for loperamide and a deuterated internal standard (methadone-d(3 were used. The lower limit of loperamide quantification was 0.2 ng/ml. This new LC-MS/MS method can be used for the detection of loperamide in any experimental setup using HEPES-buffered Ringer's solution as a matrix compound.

  19. Rotation planar chromatography coupled on-line with atmospheric pressure chemical ionization mass spectrometry.

    Science.gov (United States)

    Van Berkel, Gary J; Llave, Jonathan J; De Apadoca, Marilyn F; Ford, Michael J

    2004-01-15

    The coupling of a rotation planar preparative thin-layer chromatography system on-line with mass spectrometry is demonstrated using a simple plumbing scheme and a self-aspirating heated nebulizer probe of a corona discharge atmospheric pressure chemical ionization source. The self-aspiration of the heated nebulizer delivers approximately 20 microL/min of the 3.0 mL/min eluate stream to the mass spectrometer, eliminating the need for an external pump in the system. The viability of the coupling is demonstrated with a three-dye mixture composed of fat red 7B, solvent green 3, and solvent blue 35 separated and eluted from a silica gel-coated rotor using toluene. The real-time characterization of the dyes eluting from the rotor is illustrated in positive ion full-scan mode. Other self-aspirating ion source systems including atmospheric pressure photoionization, electrospray ionization, and inductively coupled plasma ionization, for example, might be configured and used in a similar manner coupled to the chromatograph to expand the types of analytes that could be ionized, detected, and characterized effectively.

  20. Discriminating Hodgdon Pyrodex(®) and Triple Seven(®) using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Routon, Benjamin J; Kocher, Brandon B; Goodpaster, John V

    2011-01-01

    Pyrodex(®) and Triple Seven(®) are black powder substitutes that often find use as fillers in improvised explosive devices, such as pipe bombs. These propellants have essentially the same overall appearance and oxidizers, but different fuels. For example, Pyrodex(®) contains sulfur, sodium benzoate, and dicyandiamide (DCDA), whereas Triple Seven(®) lacks sulfur but also contains 3-nitrobenzoic acid. In this method, intact particles and postblast solid residues were reacted with bis(trimethylsilyl)trifluoroacetamide + 1% trimethylchlorosilane in acetonitrile for 30 min at 60°C. The resultant trimethylsilyl derivatives of the organic fuels were then analyzed by gas chromatography-mass spectrometry. Each derivative was clearly resolved from other components, and high-quality mass spectra were obtained. In addition, characteristic fragments resulting from loss of a methyl radical from the molecular ion (m/z 163 for sulfur, m/z 171 for DCDA, m/z 179 for benzoic acid, and m/z 224 for nitrobenzoic acid) were able to be monitored.

  1. Advances in liquid chromatography-high-resolution mass spectrometry for quantitative and qualitative environmental analysis.

    Science.gov (United States)

    Aceña, Jaume; Stampachiacchiere, Serena; Pérez, Sandra; Barceló, Damià

    2015-08-01

    This review summarizes the advances in environmental analysis by liquid chromatography-high-resolution mass spectrometry (LC-HRMS) during the last decade and discusses different aspects of their application. LC-HRMS has become a powerful tool for simultaneous quantitative and qualitative analysis of organic pollutants, enabling their quantitation and the search for metabolites and transformation products or the detection of unknown compounds. LC-HRMS provides more information than low-resolution (LR) MS for each sample because it can accurately determine the mass of the molecular ion and its fragment ions if it can be used for MS-MS. Another advantage is that the data can be processed using either target analysis, suspect screening, retrospective analysis, or non-target screening. With the growing popularity and acceptance of HRMS analysis, current guidelines for compound confirmation need to be revised for quantitative and qualitative purposes. Furthermore, new commercial software and user-built libraries are required to mine data in an efficient and comprehensive way. The scope of this critical review is not to provide a comprehensive overview of the many studies performed with LC-HRMS in the field of environmental analysis, but to reveal its advantages and limitations using different workflows.

  2. Enantiomeric determination of DOPA in dietary supplements containing Mucuna pruriens by liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Hasegawa, Takashi; Takahashi, Kazunaga; Fukiwake, Tomohide; Saijo, Masaaki; Motoki, Yuji

    2013-01-01

    We developed a simple and rapid liquid chromatography/mass spectrometry (LC/MS) method for the enantiomeric determination of DOPA in dietary supplements containing Mucuna pruriens. L- and D-DOPA were ultrasonically extracted with 1% formic acid aqueous solution. The isolated extracts were analyzed by LC/MS using a Crownpak CR (-) column at 30℃. The mass spectrometer was operated in the positive mode of electrospray ionization, and the mobile phase was aqueous formic acid (pH 2.0). L-DOPA-ring-d3 was used as an internal standard. The method was validated for a dietary supplement spiked with L- and D-DOPA at 50 and 500 μg/g, respectively, and the recoveries of the DOPA enantiomers were between 97.5% and 101.3%. Relative standard deviation values of repeatability and intermediate precision were less than 7%. The method was applied to 14 dietary supplements. L-DOPA was detected in these supplements in the range of 0.88-12.8 mg/unit. D-DOPA was not detected. PMID:24190293

  3. Determination of mycophenolic acid in human plasma by ultra performance liquid chromatography tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Vivek Upadhyay; Vikas Trivedi; Gaurang Shah; Manish Yadav; Pranav S. Shrivastav

    2014-01-01

    A simple, sensitive and high throughput ultra performance liquid chromatography tandem mass spectrometry method has been developed for the determination of mycophenolic acid in human plasma. The method involved simple protein precipitation of MPA along with its deuterated analog as an internal standard (IS) from 50 mL of human plasma. The chromatographic analysis was done on Acquity UPLC C18 (100mm*2.1mm,1.7mm) column under isocratic conditions using acetonitrile and 10 mM ammonium formate, pH 3.00 (75:25, v/v) as the mobile phase. A triple quadrupole mass spectrometer operating in the positive ionization mode was used for quantitation. In-source conversion of mycophenolic glucuronide metabolite to the parent drug was selectively controlled by suitable optimization of cone voltage, cone gas flow and desolvation temperature. The method was validated over a wide concentration range of 15–15000 ng/mL. The mean extraction recovery for the analyte and IS was 495%. Matrix effect expressed as matrix factors ranged from 0.97 to 1.02. The method was successfully applied to support a bioequivalence study of 500 mg mycophenolate mofetil tablet in 72 healthy subjects.

  4. Stress degradation study and structure characterization of oxidation degradation product of dexlansoprazole using liquid chromatography-mass spectrometry/time of flight, liquid chromatography-tandem mass spectrometry and nuclear magnetic resonance

    Institute of Scientific and Technical Information of China (English)

    Lakkireddy PRAKASH; M HIMAJA

    2016-01-01

    The present study deals with the forced degradation behavior of dexlansoprazole under International Conference on Harmonisation( ICH)prescribed stress conditions. The drug was found to be more labile under acid,base,neutral,oxidative hydrolysis and thermal stress,while it was moderately stable under photolytic conditions. The known and unknown degradation products were separated on a C-18 column using a stability-indicating method. Liquid chromatography-mass spectrometry( LC-MS)analysis was performed for all the deg-radation studies. Isolation and structure characterization of oxidation degradation products were executed using sophisticated tools,viz. preparative high performance liquid chromatography( HPLC),liquid chromatography-mass spectrometry/time of flight( LC-MS/TOF),liquid chromatography-tandem mass spectrometry( LC-MS/MS),and nuclear magnetic resonance( NMR). This study demonstrates an ample methodology of degradation studies and structure elucidation of unknown degradation products of dexlansoprazole,which helps in the development and stability study of active pharmaceutical ingredients and formulated products.

  5. Qualitative and Quantitative Analysis of Andrographis paniculata by Rapid Resolution Liquid Chromatography/Time-of-Flight Mass Spectrometry

    OpenAIRE

    Jian-Fei Qin; Zhi-Yuan Jiang; Zhao Jin; Shi-Ping Liu; Yong-Xi Song

    2013-01-01

    A rapid resolution liquid chromatography/time-of-flight tandem mass spectrometry (RRLC-TOF/MS) method was developed for qualitative and quantitative analysis of the major chemical constituents in Andrographis paniculata. Fifteen compounds, including flavonoids and diterpenoid lactones, were unambiguously or tentatively identified in 10 min by comparing their retention times and accurate masses with standards or literature data. The characteristic fragmentation patterns of flavonoids and diter...

  6. Direct Measurement of Free Estradiol in Human Serum and Plasma by Equilibrium Dialysis-Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Ray, Julie A; Kushnir, Mark M; Rockwood, Alan L; Meikle, A Wayne

    2016-01-01

    We describe a direct method of measurement of free estradiol using equilibrium dialysis followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Serum aliquots and internal standards are extracted by liquid-liquid extraction using methyl-tert-butyl ether (MTBE) followed by derivatization with dansyl chloride. An API 5500 mass spectrometer operated in positive electrospray mode is used for detection. PMID:26602122

  7. Screening and confirmation criteria for hormone residue analysis using liquid chromatography accurate mass time-of-flight, Fourier transform ion cyclotron resonance and orbitrap mass spectrometry techniques

    NARCIS (Netherlands)

    Nielen, M.W.F.; Engelen, M.C. van; Zuiderent, R.; Ramaker, R.

    2007-01-01

    An emerging trend is recognised in hormone and veterinary drug residue analysis from liquid chromatography tandem mass spectrometry (LC/MS/MS) based screening and confirmation towards accurate mass alternatives such as LC coupled with time-of-flight (TOF), Fourier transform ion cyclotron resonance (

  8. Temperature-programmed high-performance liquid chromatography coupled to isotope ratio mass spectrometry.

    Science.gov (United States)

    Godin, Jean-Philippe; Hopfgartner, Gérard; Fay, Laurent

    2008-09-15

    The utility of liquid chromatography coupled to the isotope ratio mass spectrometry technique (LC-IRMS) has already been established through a variety of successful applications. However, the analytical constraint related to the use of aqueous mobile phases limits the LC separation mechanism. We report here a new strategy for high-precision (13)C isotopic analyses based on temperature-programmed LC-IRMS using aqueous mobile phases. Under these conditions, the isotopic precision and accuracy were studied. On one hand, experiments were carried out with phenolic acids using isothermal LC conditions at high temperature (170 degrees C); on the other hand, several experiments were performed by ramping the temperature, as conventionally used in a gas chromatography-based method with hydrosoluble fatty acids and pulses of CO 2 reference gas. In isothermal conditions at 170 degrees C, despite the increase of the CO 2 background, p-coumaric acid and its glucuronide conjugate gave reliable isotopic ratios compared to flow injection analysis-isotopic ratio mass spectrometry (FIA-IRMS) analyses (isotopic precision and accuracy are lower than 0.3 per thousand). On the opposite, for its sulfate conjugate, the isotopic accuracy is affected by its coelution with p-coumaric acid. Not surprisingly, this study also demonstrates that at high temperature (170 degrees C), a compound eluting with long residence time (i.e., ferulic acid) is degraded, affecting thus the delta (13)C (drift of 3 per thousand) and the peak area (compared to FIA-IRMS analysis at room temperature). Quantitation is also reported in isothermal conditions for p-coumaric acid in the range of 10-400 ng/mL and with benzoic acid as an internal standard. For temperature gradient LC-IRMS, in the area of the LC gradient (set up at 20 degrees C/min), the drift of the background observed produces a nonlinearity of SD (delta (13)C) approximately 0.01 per thousand/mV. To circumvent this drift, which impacts severely the

  9. Analysis of perfluoroalkyl substances in cord blood by turbulent flow chromatography coupled to tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Llorca, Marta; Perez, Francisca [Department of Environmental Chemistry, IDAEA-CSIC, Barcelona (Spain); Farre, Marinella, E-mail: mfuqam@cid.csic.es [Department of Environmental Chemistry, IDAEA-CSIC, Barcelona (Spain); Agramunt, Silvia [Centre for Research in Environmental Epidemiology (CREAL), Barcelona (Spain); IMIM (Hospital del Mar Research Institute), Barcelona (Spain); Kogevinas, Manolis [Centre for Research in Environmental Epidemiology (CREAL), Barcelona (Spain); IMIM (Hospital del Mar Research Institute), Barcelona (Spain); CIBER Epidemiologia y Salud Publica (CIBERESP), Barcelona (Spain); National School of Public Health, Athens (Greece); Barcelo, Damia [Department of Environmental Chemistry, IDAEA-CSIC, Barcelona (Spain); Catalan Institute for Water Research (ICRA), Girona (Spain); King Saud University, Riyadh (Saudi Arabia)

    2012-09-01

    A fast on-line analytical method based on turbulent flow chromatography (TFC) in combination with tandem mass spectrometry has been applied for the first time for the analysis of eighteen perfluoroalkyl substances (PFASs), in cord blood. A simple and rapid sample pre-treatment was optimised consisting on protein precipitation of 100 {mu}L of sample with acetonitrile (1:1) followed by centrifugation during 10 min. The method was adapted to be sensitive enough and robust with minimum sample injection volume requirements (20 {mu}L). The optimised methodology presented method limits of detection (MLOD) between 0.031 and 0.76 {mu}g/L, detection capabilities (CC{alpha}) in the range between 0.005 and 0.99 {mu}g/L and decision limits (CC{beta}) ranging from 0.006 to 1.16 {mu}g/L. The recoveries in blank blood were calculated by spiking experiments with a mixture of 18 PFASs and established between 70 and 126% for most of compounds. Isotopic dilution was carried out for quantification of selected analytes. In-house validation of this new approach was carried out according to the requirements in the 2002/657/EC Decision. Finally the good applicability of this new approach was proved by the analysis of 60 cord blood samples from two different Mediterranean cities, Barcelona (Spain) and Heraklion (Greece). Ions perfluorohexanesulfonate (PFHxS) and perfluorooctanesulfonate (PFOS) were found at highest concentration and the more frequently compounds were PFHxS, PFOS and perfluorooctanoic acid (PFOA). The newly developed method proved to be suitable for large-scale epidemiologic studies, and to the data on PFASs exposure during pregnancy. -- Highlights: Black-Right-Pointing-Pointer An on-line method has been developed for the analysis of 18 perfluoroalkyl substances. Black-Right-Pointing-Pointer The method is based on turbulent flow chromatography tandem mass spectrometry. Black-Right-Pointing-Pointer The method was applied in 60 cord blood samples from 2 Mediterranean cities

  10. Determination of seven pyrethroids and six pyrethrins in water by liquid chromatography/mass spectrometry

    Science.gov (United States)

    ccanccapa, alexander; Masia, Ana; Pico, Yolanda

    2016-04-01

    Pyrethroids are the synthetic analogues of pyrethrins which were developed as pesticides from the extracts of dried and powdered flower heads of Chrysanthemum cinerariaefolium. They are increasingly used in agriculture due to their broad biological activity and slow development of pest resistance. Contamination of fresh-water ecosystems appears either because of the direct discharge of industrial and agricultural effluents or as a result of effluents from sewage treatment works; residues can thus accumulate in the surrounding biosphere [1, 2]. These substances, mostly determined by gas chromatography mass spectrometry (GC-MS) can be difficult to analyse due to their volatility and degradability. The purpose of this study is, as an alternative, to develop a fast and sensitive multi-residue method for the target analysis of 7 pyrethroids and the 6 natural pyrethrins currently used in water samples by liquid chromatography tandem mass spectrometry (LC-MS/MS). The compounds included in the study were acrinathrin, etofenprox, cyfluthrin, esfenvalerate, cyhalothrin, cypermethrin and flumethrin as pyrethroids and a commercial mix of pyrethrins containing Cinerin I, Jasmolin I, pyrethrin I, cinerin II, jasmolin II, pyrethrins II in different percentages. As a preliminary step, the ionization and fragmentation of the compounds were optimized injecting individual solutions of each analyte at 10 ppm in the system, using a gradient elution profile of water-methanol both with 10 mM ammonium formate. The ESI conditions were: capillary voltage 4000 V, nebulizer15 psi, source temperature 300◦C and gas flow 10 L min-1. [M+H]+, [M+Na]+ ,[M+NH3]+ ,[M+NH4+]+ were tested as precursor ions. The most intense signal was for ammonium adduct for all compounds. The optimal fragmentor range for product ions were between 20 to 80 ev and the collision energy ranged between 5 to 86 ev. The efficiency of the method was tested in water samples from Turia River without any known exposure to

  11. Multivariate analysis of progressive thermal desorption coupled gas chromatography-mass spectrometry.

    Energy Technology Data Exchange (ETDEWEB)

    Van Benthem, Mark Hilary; Mowry, Curtis Dale; Kotula, Paul Gabriel; Borek, Theodore Thaddeus, III

    2010-09-01

    Thermal decomposition of poly dimethyl siloxane compounds, Sylgard{reg_sign} 184 and 186, were examined using thermal desorption coupled gas chromatography-mass spectrometry (TD/GC-MS) and multivariate analysis. This work describes a method of producing multiway data using a stepped thermal desorption. The technique involves sequentially heating a sample of the material of interest with subsequent analysis in a commercial GC/MS system. The decomposition chromatograms were analyzed using multivariate analysis tools including principal component analysis (PCA), factor rotation employing the varimax criterion, and multivariate curve resolution. The results of the analysis show seven components related to offgassing of various fractions of siloxanes that vary as a function of temperature. Thermal desorption coupled with gas chromatography-mass spectrometry (TD/GC-MS) is a powerful analytical technique for analyzing chemical mixtures. It has great potential in numerous analytic areas including materials analysis, sports medicine, in the detection of designer drugs; and biological research for metabolomics. Data analysis is complicated, far from automated and can result in high false positive or false negative rates. We have demonstrated a step-wise TD/GC-MS technique that removes more volatile compounds from a sample before extracting the less volatile compounds. This creates an additional dimension of separation before the GC column, while simultaneously generating three-way data. Sandia's proven multivariate analysis methods, when applied to these data, have several advantages over current commercial options. It also has demonstrated potential for success in finding and enabling identification of trace compounds. Several challenges remain, however, including understanding the sources of noise in the data, outlier detection, improving the data pretreatment and analysis methods, developing a software tool for ease of use by the chemist, and demonstrating our belief

  12. Gas chromatography: mass selective detector

    International Nuclear Information System (INIS)

    The mechanism of mass spectrometry technique directed for detecting molecular structures is described, with some considerations about its operational features. This mass spectrometer is used as a gas chromatography detector. (author)

  13. Application of liquid chromatography-tandem mass spectrometry in quantitative bioanalyses of organic molecules in aquatic environment and organisms.

    Science.gov (United States)

    Bussy, Ugo; Li, Ke; Li, Weiming

    2016-05-01

    Analytical methods using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of metabolites or contaminants (or both) in various tissues of aquatic organisms and in the aquatic environment have received increasing attention in the last few years. This review discusses the findings relevant to such procedures published between 2005 and 2015. The aim is to evaluate the advantages, restrictions, and performances of the procedures from sample preparation to mass spectrometry measurement. To support these discussions, a general knowledge on LC-MS/MS is also provided. PMID:26996906

  14. Analysis of small carbohydrates in several bioactive botanicals by gas chromatography with mass spectrometry and liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Moldoveanu, Serban; Scott, Wayne; Zhu, Jeff

    2015-11-01

    Bioactive botanicals contain natural compounds with specific biological activity, such as antibacterial, antioxidant, immune stimulating, and taste improving. A full characterization of the chemical composition of these botanicals is frequently necessary. A study of small carbohydrates from the plant materials of 18 bioactive botanicals is further described. The study presents the identification of the carbohydrate using a gas chromatographic-mass spectrometric analysis that allows detection of molecules as large as maltotetraose, after changing them into trimethylsilyl derivatives. A number of carbohydrates in the plant (fructose, glucose, mannose, sucrose, maltose, xylose, sorbitol, and myo-, chiro-, and scyllo-inositols) were quantitated using a novel liquid chromatography with tandem mass spectrometric technique. Both techniques involved new method developments. The gas chromatography with mass spectrometric analysis involved derivatization and separation on a Rxi(®)-5Sil MS column with H2 as a carrier gas. The liquid chromatographic separation was obtained using a hydrophilic interaction type column, YMC-PAC Polyamine II. The tandem mass spectrometer used an electrospray ionization source in multiple reaction monitoring positive ion mode with the detection of the adducts of the carbohydrates with Cs(+) ions. The validated quantitative procedure showed excellent precision and accuracy allowing the analysis in a wide range of concentrations of the analytes.

  15. Anion exchange SPE and liquid chromatography-tandem mass spectrometry in GHB analysis.

    Science.gov (United States)

    Elian, Albert A; Hackett, Jeffery

    2011-12-01

    In this study, the extraction of γ-hydroxybutyrate (GHB) from urine using solid-phase extraction (SPE) is described. SPE was performed on anion exchange columns after samples of urine had been diluted with de-ionized water. After application of the diluted samples containing GHB-d(6) as an internal standard, the sorbent was washed with deionized water and methanol and dried. The GHB was eluted from the SPE column with a solvent consisting of methanol containing 6% glacial acetic acid. The eluent was collected, evaporated to dryness, and dissolved in mobile phase (100 μL) for analysis by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in negative multiple reaction monitoring (MRM) mode. Liquid chromatography was performed in gradient mode employing a biphenyl column and a mobile phase consisting of acetontitrile (containing 0.1% formic acid) and 0.1% aqueous formic acid. The total run time for each analysis was less than 5 min. The limits of detection/quantification for this method were determined to be 50 and 100 ng/mL, respectively. The method was found to be linear from 500 ng/mL to 10,000 ng/mL (r(2)>0.995). The recovery of GHB was found to be greater than 75%. In this report, results of authentic urine samples analyzed for GHB by this method are presented. GHB concentrations in these samples were found to be range from less than 500 ng/mL to 5110 ng/mL.

  16. Determination of the origin of urinary norandrosterone traces by gas chromatography combustion isotope ratio mass spectrometry.

    Science.gov (United States)

    Hebestreit, Moritz; Flenker, Ulrich; Fusshöller, Gregor; Geyer, Hans; Güntner, Ute; Mareck, Ute; Piper, Thomas; Thevis, Mario; Ayotte, Christiane; Schänzer, Wilhelm

    2006-09-01

    On the one hand, 19-norandrosterone (NA) is the most abundant metabolite of the synthetic anabolic steroid 19-nortestosterone and related prohormones. On the other hand, small amounts are biosynthesized by pregnant women and further evidence exists for physiological origin of this compound. The World Anti-Doping Agency (WADA) formerly introduced threshold concentrations of 2 or 5 ng of NA per ml of urine to discriminate 19-nortestosterone abuse from biosynthetic origin. Recent findings showed however, that formation of NA resulting in concentrations in the range of the threshold levels might be due to demethylation of androsterone in urine, and the WADA 2006 Prohibited List has defined NA as endogenous steroid. To elucidate the endogenous or exogenous origin of NA, (13)C/(12)C-analysis is the method of choice since synthetic 19-nortestosterone is derived from C(3)-plants by partial synthesis and shows delta(13)C(VPDB)-values of around -28 per thousand. Endogenous steroids are less depleted in (13)C due to a dietary mixture of C(3)- and C(4)-plants. An extensive cleanup based on two high performance liquid chromatography cleanup steps was applied to quality control and doping control samples, which contained NA in concentrations down to 2 ng per ml of urine. (13)C/(12)C-ratios of NA, androsterone and etiocholanolone were measured by gas chromatography/combustion/isotope ratio mass spectrometry. By comparing delta(13)C(VPDB)-values of androsterone as endogenous reference compound with NA, the origin of NA in doping control samples was determined as either endogenous or exogenous.

  17. Mass spectrometry

    DEFF Research Database (Denmark)

    Nyvang Hartmeyer, Gitte; Jensen, Anne Kvistholm; Böcher, Sidsel;

    2010-01-01

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is currently being introduced for the rapid and accurate identification of bacteria. We describe 2 MALDI-TOF MS identification cases - 1 directly on spinal fluid and 1 on grown bacteria. Rapidly obtained r...

  18. Evaluation of column hardware on liquid chromatography-mass spectrometry of phosphorylated compounds.

    Science.gov (United States)

    Sakamaki, Hiroshi; Uchida, Takeharu; Lim, Lee Wah; Takeuchi, Toyohide

    2015-02-13

    The influences of column hardware, such as chromatographic tubes and frits, on liquid chromatography-mass spectrometry (LC-MS) analysis of phosphorylated compounds were evaluated. The signal to noise ratio (S/N) and the intensity of flavin adenine dinucleotide (FAD) using a glass lined tube and polyethylene frit (GL-PE) column was approximately 170 and 90 times higher, respectively, than those using conventional stainless steel tube and stainless steel frit (S-S) column. In addition, the retention time of FAD using GL-PE column was the shortest compared to other columns. Interaction between phosphorylated compounds and metal ions in the flow path in the S-S column was stronger than that between them and the GL-PE column. Thus, the metal ions in the flow path in GL-PE column were low. Since the specific surface area of a pair of frits was 70 times larger than that of a chromatographic tube (150 mm×2.1 mm), the frits were found to have more effective improvement of the S/N as well as the intensity than the chromatographic tubes, when phosphorylated compounds were analyzed by LC-MS. When the evaluated phosphorylated compounds were analyzed by LC-MS(/MS) using a GL-PE column, the intensity and S/N were increased.

  19. Vinegar Metabolomics: An Explorative Study of Commercial Balsamic Vinegars Using Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    Pinu, Farhana R.; de Carvalho-Silva, Samuel; Trovatti Uetanabaro, Ana Paula; Villas-Boas, Silas G.

    2016-01-01

    Balsamic vinegar is a popular food condiment produced from cooked grape must by two successive fermentation (anaerobic and aerobic) processes. Although many studies have been performed to determine the composition of major metabolites, including sugars and aroma compounds, no study has been undertaken yet to characterize the comprehensive metabolite composition of balsamic vinegars. Here, we present the first metabolomics study of commercial balsamic vinegars by gas chromatography coupled to mass spectrometry (GC-MS). The combination of three GC-MS methods allowed us to detect >1500 features in vinegar samples, of which 123 metabolites were accurately identified, including 25 amino acids, 26 carboxylic acids, 13 sugars and sugar alcohols, four fatty acids, one vitamin, one tripeptide and over 47 aroma compounds. Moreover, we identified for the first time in vinegar five volatile metabolites: acetin, 2-methylpyrazine, 2-acetyl-1-pyroline, 4-anisidine and 1,3-diacetoxypropane. Therefore, we demonstrated the capability of metabolomics for detecting and identifying large number of metabolites and some of them could be used to distinguish vinegar samples based on their origin and potentially quality. PMID:27455339

  20. Development of a high-performance liquid chromatography - Tandem mass spectrometry urinary pterinomics workflow.

    Science.gov (United States)

    Burton, Casey; Shi, Honglan; Ma, Yinfa

    2016-07-13

    Pteridines have evoked considerable interest from the scientific community owing to their prominent roles in human health and disease. The availability of analytical methodologies suitable for comprehensive pteridine profiling, termed here as "pterinomics", has been limited by inconsistent sample preparation and the exclusion of lesser studied pteridine derivatives. In response, the present study describes a new pterinomics workflow using a high-performance liquid chromatography - tandem mass spectrometry (HPLC-MS/MS) methodology for the simultaneous analysis of 15 pteridine derivatives including four structural isomers, marking the largest quantitative pteridine panel that has been studied to-date. The validated method possessed excellent sensitivity with method detection limits (0.025 μg L(-1) to 0.5 μg L(-1)) that were comparable or superior to existing techniques. Spiked recovery studies demonstrated the technique was both accurate (88-112%) and precise (RSD: 0-6%). A comparative study of commonly used oxidative pretreatments, including triiodide, permanganate, and manganese dioxide, revealed that the oxidative mechanisms were inefficient, complex, and concentration dependent. Finally, 50 clinical urine specimens were examined with the new technique wherein 10 pteridine derivatives were quantified and population ranges have been given. This technique can be used to examine pteridine molecular epidemiology and biochemistry to support related research applications, and may further be readily extended to include additional pteridine derivatives and biological matrices for specific applications. PMID:27237839

  1. Determination of Synthetic Cathinones in Urine Using Gas Chromatography-Mass Spectrometry Techniques.

    Science.gov (United States)

    Hong, Wei-Yin; Ko, Ya-Chun; Lin, Mei-Chih; Wang, Po-Yu; Chen, Yu-Pen; Chiueh, Lih-Ching; Shih, Daniel Yang-Chih; Chou, Hsiu-Kuan; Cheng, Hwei-Fang

    2016-01-01

    In recent years, the abuse of synthetic cathinones has increased considerably. This study proposes a method, based on gas chromatography/mass spectrometry (GC-MS), to analyze and quantify six synthetic cathinones in urine samples: mephedrone (4-MMC), methylone (bk-MDMA), butylone, ethylone, pentylone and methylenedioxypyrovalerone (MDPV). In our procedure, the urine samples undergo solid-phase extraction (SPE) and derivatization prior to injection into the GC-MS device. Separation is performed using a HP-5MS capillary column. The use of selective ion monitoring (SIM mode) makes it is good sensitivity in this method, and the entire analysis process is within 18 min. In addition, the proposed method maintains linearity in the calibration curve from 50 to 2,000 ng/mL (r(2) > 0.995). The limit of detection of this method is 5 ng/mL, with the exception of MDPV (20 ng/mL); the limit of quantification is 20 ng/mL, with the exception of MDPV (50 ng/mL). In testing, the extraction performance of SPE was between 82.34 and 104.46%. Precision and accuracy results were satisfactory MDMA. Our results demonstrate the efficacy of the proposed method in the identification of synthetic cathinones in urine, with regard to the limits of detection and quantification. This method is highly repeatable and accurate. PMID:26410364

  2. Gluten Detection and Speciation by Liquid Chromatography Mass Spectrometry (LC-MS/MS

    Directory of Open Access Journals (Sweden)

    Stephen Lock

    2013-12-01

    Full Text Available Liquid chromatography tandem mass spectrometry (LC-MS/MS has been used historically in proteomics research for over 20 years. However, until recently LC-MS/MS has only been routinely used in food testing for small molecule contaminant detection, for example pesticide and veterinary residue detection, and not as a replacement of microbiological food testing methods, specifically allergen analysis. Over the last couple of years, articles have started to be published which describe the detection of allergens by LC-MS/MS. In this article we will describe how LC-MS/MS can be applied in the area of gluten detection and how it can be used to specifically differentiate the species of gluten used in food, where specific markers for each variety of gluten can be simultaneously acquired and detected at the same time. The article will discuss the effect of variety on the peptide response observed from different wheat grain varieties and will describe the sample preparation protocol which is essential for generating the peptide markers used for speciation.

  3. [Determination of gossypol in edible vegetable oil with high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Zhang, Wenhua; Huang, Chaoqun; Xie, Wen; Shen, Li

    2014-06-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of gossypol in edible vegetable oil. The sample was extracted with ethyl alcohol by vortex-excited oscillation. The extract was cleaned up by 0.22 microm filter membrane and centrifuged for 5 min at 4 000 r/min after standing in a fridge at 4 degrees C for 30 min. The compound was separated on a C18 column (100 mm x 2.1 mm, 3.5 microm) with acetonitrile and 1% (v/v) formic acid aqueous solution as mobile phase. The detection of gossypol was carried out by LC-MS/MS with positive electrospray ionization under multiple reaction monitoring (MRM) mode using external standard method. The limits of quantification (S/N > 10) of gossypol in edible vegetable oil was 1 mg/kg. The recoveries were from 87.4% to 100% at the spiked levels of 1, 2, 200 mg/kg of gossypol in edible vegetable oil with the relative standard deviations (RSDs) between 3.9% and 12.2%. The method, with high sensitivity, good precision and high recovery, was suitable for the confirmation and quantification of gossypol residue in edible vegetable oil. PMID:25269254

  4. Determination of terpenes in tequila by solid phase microextraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Peña-Alvarez, Araceli; Capella, Santiago; Juárez, Rocío; Labastida, Carmen

    2006-11-17

    Solid phase microextraction and capillary gas chromatography-mass spectrometry were used for the determination of seven terpenes in tequila. The method was selected based on the following parameters: coating selection (PA, PDMS, CW/DVB, and PDMS/DVB), extraction temperature, addition of salt, and extraction time profile. The extraction conditions were: PDMS/DVB fiber, Headspace, 100% NaCl, 25 degrees C extraction temperature, 30 min extraction time and stirring at 1200 rpm. The calibration curves (50-1000 ng/ml) for the terpenes followed linear relationships with correlation coefficients (r) greater than 0.99, except for trans,trans-farnesol (r = 0.98). RSD values were smaller than 10% confirmed that the technique was precise. Samples from 18 different trade brands of "Aged" tequila analyzed with the developed method showed the same terpenes in different concentrations. The analytical procedure used is selective, robust (more than 100 analyses with the same fiber), fast and of low-cost.

  5. Analysis of plant nucleotide sugars by hydrophilic interaction liquid chromatography and tandem mass spectrometry.

    Science.gov (United States)

    Ito, Jun; Herter, Thomas; Baidoo, Edward E K; Lao, Jeemeng; Vega-Sánchez, Miguel E; Michelle Smith-Moritz, A; Adams, Paul D; Keasling, Jay D; Usadel, Björn; Petzold, Christopher J; Heazlewood, Joshua L

    2014-03-01

    Understanding the intricate metabolic processes involved in plant cell wall biosynthesis is limited by difficulties in performing sensitive quantification of many involved compounds. Hydrophilic interaction liquid chromatography is a useful technique for the analysis of hydrophilic metabolites from complex biological extracts and forms the basis of this method to quantify plant cell wall precursors. A zwitterionic silica-based stationary phase has been used to separate hydrophilic nucleotide sugars involved in cell wall biosynthesis from milligram amounts of leaf tissue. A tandem mass spectrometry operating in selected reaction monitoring mode was used to quantify nucleotide sugars. This method was highly repeatable and quantified 12 nucleotide sugars at low femtomole quantities, with linear responses up to four orders of magnitude to several 100pmol. The method was also successfully applied to the analysis of purified leaf extracts from two model plant species with variations in their cell wall sugar compositions and indicated significant differences in the levels of 6 out of 12 nucleotide sugars. The plant nucleotide sugar extraction procedure was demonstrated to have good recovery rates with minimal matrix effects. The approach results in a significant improvement in sensitivity when applied to plant samples over currently employed techniques.

  6. Multiresidue Analysis of Pesticides in Straw Roughage by Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Zhang, Zihao; Feng, Mengyuan; Zhu, Kechen; Han, Lijun; Sapozhnikova, Yelena; Lehotay, Steven J

    2016-08-10

    A multiresidue analytical method using a modification of the "quick, easy, cheap, effective, rugged, and safe" (QuEChERS) sample preparation approach combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis was established and validated for the rapid determination of 69 pesticides at different levels (1-100 ng/g) in wheat and rice straws. In the quantitative analysis, the recoveries ranged from 70 to 120%, and consistent RSDs ≤ 20% were achieved for most of the target analytes (53 pesticides in wheat straw and 58 in rice straw). Almost all of the analytes achieved good linearity with R(2) > 0.98, and the limit of validation levels (LVLs) for diverse pesticides ranged from 1 to 10 ng/g. Different extraction and cleanup conditions were evaluated in both types of straw, leading to different options. The use of 0.1% formic acid or not in extraction with acetonitrile yielded similar final outcomes, but led to the use of a different sorbent in dispersive solid-phase extraction. Both options are efficient and useful for the multiresidue analysis of targeted pesticides in wheat and rice straw samples. PMID:26881844

  7. Multi-class method for biomonitoring of hair samples using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Martín, Julia; Möder, Monika; Gaudl, Alexander; Alonso, Esteban; Reemtsma, Thorsten

    2015-11-01

    Currently, non-invasive biomonitoring of human exposure to organic pollutants bases upon the analysis mainly of urine and human breast milk. While mostly persistent organic pollutants are the center of interest, the aim of our study was to develop a method for the determination of different chemical classes of emerging pollutants (organophosphorus flame retardants, plastic additives such as phthalates, bisphenol A, insecticides, antimicrobials, preservatives and musk fragrances) in hair by gas chromatography-mass spectrometry. The preferred sample preparation included hydrolysis of the hair with trifluoroacetic acid in methanol followed by a liquid-liquid extraction using hexane/ethyl acetate. The validated method is characterized by recoveries higher than 77 % for most analytes, relative standard deviations below 16 % and limits of detection between 2 pg mg(-1) (HHCB) and 292 pg mg(-1) (propylparaben) using 50 mg of dry hair. After respective blank corrections, bis-(2-ethylhexyl)phthalate (DEHP) and the musk fragrance HHCB were the predominant compounds determined in all hair samples at concentrations between 32 and 59 ng mg(-1) and 0.8-13 ng mg(-1), respectively. The bactericide triclosan and the insect repellent N,N-diethyl-3-methylbenzamide (DEET) were detected in selected hair samples at 2 and 0.8 ng mg(-1), respectively. PMID:26427497

  8. Determination of ribavirin in human serum using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    van der Lijke, Henk; Alffenaar, Jan-Willem C; Kok, Wim Th; Greijdanus, Ben; Uges, Donald R A

    2012-01-15

    A method has been developed for the determination of ribavirin in human serum for therapeutic drug monitoring purposes, using liquid chromatography electrospray ionization mass spectrometry. Separation was obtained with a mobile phase gradient starting and ending in 100% aqueous conditions using a Waters Atlantis® T3 column (100×2mm, 3μm). The entire sample preparation consisted of dilution, followed by ultrafiltration. From the clear ultrafiltrate 5μL was injected on the LC-MS/MS system. The calibration curves were linear in the range of 0.2-10mg/L with within-run and between-run precisions (CVs) in the range of 0-10%. The method was validated with respect to specificity, selectivity, linearity, accuracy, precision, recovery and stability and meets the requirements of the FDA. The method was extensively tested for matrix effects by determining the variation of the slopes of calibration curves in different sources of serum and plasma. This method is suitable for the determination of ribavirin in human serum for therapeutic drug monitoring. PMID:22265514

  9. Arsenic speciation in soil using high performance liquid chromatography/inductively coupled plasma/mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Bass, D.A.; Yaeger, J.S.; Parish, K.J.; Crain, J.S.; Kiely, J.T.; Gowdy, M.J. [Argonne National Lab., IL (United States); Mohrman, G.B.; Besmer, M.G. [Rocky Mountain Arsenal, Commerce City, CO (United States)

    1996-08-01

    A method has been developed to identify and quantify As(III), As(V), and organoarsenic compounds in soil samples from the Rocky Mountain Arsenal (RMA) by high performance liquid chromatography/inductively coupled plasma/mass spectrometry (HPLC/ICP/MS). The soils were extracted using tetrabutylammonium hydroxide (TBAH) and sonication. The percentages of As(III), As(V), and organoarsenic species extracted from soil samples were 30, 50, and 100 respectively. The arsenic species were not altered during the extraction process. They were separated by reversed-phase, ion-pairing, HPLC using a microbore Inertsil-ODS{trademark} column. The HPLC column effluent was introduced into an ICP/MS system using a direct injection nebulizer (DIN). Detection limits of less than 1 pg were readily obtained for each arsenic species. Internal standards are recommended to increase accuracy and precision. Soil samples spiked with arsenic oxide, sodium arsenate, dimethylarsinic acid (DMAA), and chlorovinyl arsenious acid (CVAA) were extracted, identified and quantified with the HPLC/ICP/MS system. The soil samples were analyzed in support of the analytical needs of a thermal desorption treatability study being conducted at the RMA.

  10. Postmortem interval estimation: a novel approach utilizing gas chromatography/mass spectrometry-based biochemical profiling.

    Science.gov (United States)

    Kaszynski, Richard H; Nishiumi, Shin; Azuma, Takeshi; Yoshida, Masaru; Kondo, Takeshi; Takahashi, Motonori; Asano, Migiwa; Ueno, Yasuhiro

    2016-05-01

    While the molecular mechanisms underlying postmortem change have been exhaustively investigated, the establishment of an objective and reliable means for estimating postmortem interval (PMI) remains an elusive feat. In the present study, we exploit low molecular weight metabolites to estimate postmortem interval in mice. After sacrifice, serum and muscle samples were procured from C57BL/6J mice (n = 52) at seven predetermined postmortem intervals (0, 1, 3, 6, 12, 24, and 48 h). After extraction and isolation, low molecular weight metabolites were measured via gas chromatography/mass spectrometry (GC/MS) and examined via semi-quantification studies. Then, PMI prediction models were generated for each of the 175 and 163 metabolites identified in muscle and serum, respectively, using a non-linear least squares curve fitting program. A PMI estimation panel for muscle and serum was then erected which consisted of 17 (9.7%) and 14 (8.5%) of the best PMI biomarkers identified in muscle and serum profiles demonstrating statistically significant correlations between metabolite quantity and PMI. Using a single-blinded assessment, we carried out validation studies on the PMI estimation panels. Mean ± standard deviation for accuracy of muscle and serum PMI prediction panels was -0.27 ± 2.88 and -0.89 ± 2.31 h, respectively. Ultimately, these studies elucidate the utility of metabolomic profiling in PMI estimation and pave the path toward biochemical profiling studies involving human samples. PMID:26931122

  11. Identification of tartary buckwheat tea aroma compounds with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Qin, Peiyou; Ma, Tingjun; Wu, Li; Shan, Fang; Ren, Guixing

    2011-08-01

    Tartary buckwheat tea, which is an important and healthy product, has a distinct malty aroma. However, its characteristic aroma compounds have not been elucidated. The aims of present study were identification and quantification of its aroma compounds. The analyses were performed by gas chromatography-mass spectrometry (GC-MS) after 3 different isolation techniques. Seventy-seven compounds were identified. Among these compounds, 35 were quantified by available standards. The compounds with a high probability of contribution to the tartary buckwheat tea aroma (OAV ≥ 10) were as follows: 2,5-dimethyl-4-hydroxy-3(2H)-furanone, nonanal, 2,3-diethyl-5-methylpyrazine, benzeneacetaldehyde, maltol, 2,5-dimethylpyrazine, 2-ethyl-5-methylpyrazine, trimethylpyrazine. Some nutritional and bioactive compounds were also identified in this study, such as linoleic acid, niacin, vanillic acid, 7-hydroxycoumarin, butylated hydroxytoluene. Practical Application: Tartary buckwheat, one type of buckwheat, has gained much attention from nutritionists and medical doctors in recent years. It is rich in rutin, quercetin, and other nutrients that are good for health. Tartary buckwheat-based product such as tartary buckwheat tea is an important and popular healthy product in China, Japan,South Korea, European countries as well as in American countries. It has a distinct malty aroma. The present study first identified and quantified of its aroma compounds. The results will draw attention to other researchers in food flavor and buckwheat filed. PMID:22417522

  12. Analysis of endogenous aldehydes in human urine by static headspace gas chromatography-mass spectrometry.

    Science.gov (United States)

    Serrano, María; Gallego, Mercedes; Silva, Manuel

    2016-03-11

    Endogenous aldehydes (EAs) generated during oxidative stress and cell processes are associated with many pathogenic and toxicogenic processes. The aim of this research was to develop a solvent-free and automated analytical method for the determination of EAs in human urine using a static headspace generator sampler coupled with gas chromatography-mass spectrometry (HS-GC-MS). Twelve significant EAs used as markers of different biochemical and physiological processes, namely short- and medium-chain alkanals, α,β-unsaturated aldehydes and dicarbonyl aldehydes have been selected as target analytes. Human urine samples (no dilution is required) were derivatized with O-2,3,4,5,6-pentafluorobenzylhydroxylamine in alkaline medium (hydrogen carbonate-carbonate buffer, pH 10.3). The HS-GC-MS method developed renders an efficient tool for the sensitive and precise determination of EAs in human urine with limits of detection from 1 to 15ng/L and relative standard deviations, (RSDs) from 6.0 to 7.9%. Average recoveries by enriching urine samples ranged between 92 and 95%. Aldehydes were readily determined at 0.005-50μg/L levels in human urine from healthy subjects, smokers and diabetic adults.

  13. Chemical Discrimination in Turbulent Gas Mixtures with MOX Sensors Validated by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Jordi Fonollosa

    2014-10-01

    Full Text Available Chemical detection systems based on chemo-resistive sensors usually include a gas chamber to control the sample air flow and to minimize turbulence. However, such a kind of experimental setup does not reproduce the gas concentration fluctuations observed in natural environments and destroys the spatio-temporal information contained in gas plumes. Aiming at reproducing more realistic environments, we utilize a wind tunnel with two independent gas sources that get naturally mixed along a turbulent flow. For the first time, chemo-resistive gas sensors are exposed to dynamic gas mixtures generated with several concentration levels at the sources. Moreover, the ground truth of gas concentrations at the sensor location was estimated by means of gas chromatography-mass spectrometry. We used a support vector machine as a tool to show that chemo-resistive transduction can be utilized to reliably identify chemical components in dynamic turbulent mixtures, as long as sufficient gas concentration coverage is used. We show that in open sampling systems, training the classifiers only on high concentrations of gases produces less effective classification and that it is important to calibrate the classification method with data at low gas concentrations to achieve optimal performance.

  14. Determination of Morphine and Codeine in Human Urine by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Xiaoqian Zhang

    2013-01-01

    Full Text Available A sensitive and selective gas chromatography-mass spectrometry (GC-MS method was developed and validated for the determination of morphine and codeine in human urine. The GC-MS conditions were developed. The analysis was carried out on a HP-1MS column (30 m × 0.25 mm, 0.25 μm with temperature programming, and Helium was used as the carrier gas with a flow rate of 1.0 mL/min. Selected ion monitoring (SIM mode was used to quantify morphine and codeine. The derivation solvent, temperature, and time were optimized. A mixed solvent of propionic anhydride and pyridine (5 : 2 was finally used for the derivation at 80°C for 3 min. Linear calibration curves were obtained in the concentration range of 25–2000.0 ng/mL, with a lower limit of quantification of 25 ng/mL. The intra- and interday precision (RSD values were below 13%, and the accuracy was in the range 87.2–108.5%. This developed method was successfully used for the determination of morphine and codeine in human urine for forensic identification study.

  15. A rapid quantitative method of carisoprodol and meprobamate by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Essler, Shannon; Bruns, Kerry; Frontz, Michael; McCutcheon, J Rod

    2012-11-01

    The identification and quantitation of carisoprodol (Soma) and its chief metabolite meprobamate, which is also a clinically prescribed drug, remains a challenge for forensic toxicology laboratories. Carisoprodol and meprobamate are notable for their widespread use as muscle relaxants and their frequent identification in the blood of impaired drivers. Routine screening is possible in both an acidic/neutral pH screen and a traditional basic screen. An improvement in directed testing quantitations was desirable over the current options of an underivatized acidic/neutral extraction or a basic screen, neither of which used ideal internal standards. A new method was developed that utilized a simple protein precipitation, deuterated internal standards and a short 2-min isocratic liquid chromatography separation, followed by multiple reaction monitoring with tandem mass spectrometry. The linear quantitative range for carisoprodol was determined to be 1-35mg/L and for meprobamate was 0.5-50mg/L. The method was validated for specificity and selectivity, matrix effects, and accuracy and precision. PMID:23040985

  16. The analysis of common metabolites of organophosphorus pesticides in urine by gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Most organophosphorus pesticides may be metabolized to yield some common phosphates in human or in animals, and these metabolites may be used as the exposure biomarkers to pesticides. In this study, we developed the extraction method of four phosphate metabolites from the spiked human urine in high recovery by the solid phase extraction with a reverse-phase cartridge (cyclohexyl silica) followed by the elution with methanol. The extracted urinary metabolites were derivatized with hexamethyldisilazane/trimethyl-chlorosilane/pyridine (2:1:10, v/v/v) and identified by gas chromatography/mass spectrometry. Calibration curve obtained from each metabolite standard using by GC/MS/SIM has shown good linearity and detection limits of metabolites were the range of 0.05-0.1 μg/ml in urine. Phenthoate, one of the organophosphorus pesticides, was orally administrated to rats. Four metabolites were detected in the rat urine. The results of this study may be applied to development of exposure biomarkers for monitoring of environmental pollutants

  17. Determination of fenbendazole and oxfendazole in liver and muscle using liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Blanchflower, W J; Cannavan, A; Kennedy, D G

    1994-06-01

    A method has been developed for the determination of the anthelmintics fenbendazole and oxfendazole in liver and muscle samples using liquid chromatography-thermospray mass spectrometry (LC-MS). The samples were homogenized with water, sonicated with methanol and centrifuged. The supernatants were washed with light petroleum and extracted with diethyl ether-ethyl acetate. The extracts were evaporated to dryness, dissolved in mobile phase and injected into the LC-MS system. Fenbendazole and oxfendazole were measured separately using two different mobile phases. Single-ion monitoring of the positive ion at m/z 300 was used for fenbendazole and of m/z 316 for oxfendazole. The detection limits for the assay were 0.05 microgram g-1 for fenbendazole and 0.1 microgram g-1 for oxfendazole. The mean recoveries were 91% for fenbendazole and 86% for oxfendazole. The assay has been used for statutory testing purposes and for measuring the levels of fenbendazole and oxfendazole in liver and muscle from sheep after dosing with a commercial anthelmintic containing fenbendazole.

  18. Liquid chromatography quadrupole time-of-flight mass spectrometry selective determination of ochratoxin A in wine.

    Science.gov (United States)

    Rodríguez-Cabo, T; Rodríguez, I; Ramil, M; Cela, R

    2016-05-15

    The performance of liquid chromatography quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) for ochratoxin A (OTA) determination in wine is evaluated for the first time. Sample preparation was optimized to obtain quantitative recoveries at the same time that the efficiency of electrospray ionization (ESI) remained unaltered between sample extracts and calibration standards. Under final conditions, samples (20 mL) were concentrated using a reversed-phase solid-phase extraction (SPE) cartridge, followed by OTA elution with 1 mL of ethyl acetate. The absolute recoveries of the method, established against calibration standards, were 91-121% and 90-113% (without and with internal standard correction, respectively), for wines fortified at 3 concentration levels. The attained LOQ (0.05 ng mL(-1)) remained below the maximum permitted OTA concentration (2 ng mL(-1)) in dry wines. The method was applied to different samples, with OTA being found in some dessert wines at concentrations below 1 ng mL(-1). The ethyl ester of OTA (OTC) could be identified in the same wine samples from its accurate full product ion spectra. PMID:26775988

  19. Global Analysis of the Membrane Subproteome of Pseudomonas aeruginosa using Liquid Chromatography-Tandem Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Blonder, Josip; Goshe, Michael B.; Xiao, Wenzhong; Camp, David G.; Wingerd, Mark A.; Davis, Ronald W.; Smith, Richard D.

    2004-05-30

    Pseudomonas aeruginosa is one of the most significant opportunistic bacterial pathogens in humans causing infections and premature death in patients with cystic fibrosis, AIDS, severe burns, organ transplants or cancer. Liquid chromatography coupled online with tandem mass spectrometry (LC-MS/MS) was used for the large-scale proteomic analysis of the P. aeruginosa membrane subproteome. Concomitantly, an affinity labeling technique, using iodoacetyl-PEO biotin to tag cysteinyl-containing proteins, permitted the enrichment and detection of lower abundance membrane proteins. The application of these approaches resulted in the identification of 786 proteins. A total of 333 proteins (42%) had a minimum of one transmembrane domain (TMD; ranging from 1 to 14) and 195 proteins were classified as hydrophobic based on their positive GRAVY values (ranging from 0.01 to 1.32). Key integral inner and outer membrane proteins involved in adaptation and antibiotic resistance were conclusively identified, including the detection of 53% of all predicted opr-type porins (outer integral membrane proteins) and all the components of the mexA-mexB-oprM transmembrane protein complex. This work represents the most comprehensive qualitative proteomic analysis of the membrane subproteome of P. aeruginosa and for prokaryotes in general to date.

  20. Structural investigations of neuromelanin by pyrolysis-gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Pyrolysis combined with gas chromatography and mass spectrometry (Py-GC/MS) was applied for structural investigations of the human substantia nigra neuromelanin. Using synthetic neuromelanins, we have demonstrated that Py-GC/MS is suitable for identification and differentiation of both eumelanin (dopamine-derived) and pheomelanin (cysteinyldopamine-derived) component of the pigment. Structural information on melanin monomers was inferred from their pyrolytic markers. When the human neuromelanin was subjected to pyrolysis, none of the heterocyclic, sulfur-containing markers of pheomelanin component was detected among the thermal degradation products. We have concluded that nigral pigment isolated from normal brain tissue does not contain benzothiazine-type monomers, and that cysteinyldopamine-originated units may be incorporated into the polymer in uncyclized form. The most abundant pyrolysis product was identified as limonene, which indicates that nigral pigment is tightly associated with an isoprenoid-type compound. Pyrolysis in the presence of the methylating reagent allowed identification of high levels of saturated and monounsaturated straight-chain C14-C18 fatty acid species chemically bound to the pigment macromolecule. (author)

  1. Validation of salivary cortisol and testosterone assays in chimpanzees by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kutsukake, Nobuyuki; Ikeda, Koki; Honma, Seijiro; Teramoto, Migaku; Mori, Yusuke; Hayasaka, Ikuo; Yamamoto, Rain; Ishida, Takafumi; Yoshikawa, Yasuhiro; Hasegawa, Toshikazu

    2009-08-01

    Owing to its high temporal sensitivity, saliva has distinct advantages for measuring steroids, compared with other noninvasive samples such as urine and feces. Here, we report the validity of assaying salivary cortisol (C) and testosterone (T) using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in captive male chimpanzees, Pan troglodytes. For both the C and T concentrations, we found positive relationships between saliva and plasma. The concentrations of C and T in saliva showed clear patterns of diurnal fluctuation, whereas those in urine and feces did not. These results suggest that the salivary steroid concentrations can be regarded as good indicators of circulating steroid levels. We also developed and validated an efficient method for collecting saliva samples from cotton rope. Although rope includes inherent steroid-like compounds and may affect the accuracy of steroid measurements, our rope-washing procedures effectively removed intrinsic steroidal materials. There was a significant association between the C and T concentrations measured from saliva collected from rope licked by the chimpanzees and those measured from saliva collected directly from the mouth. Salivary T values estimated by LC/MS-MS were similar to those measured by radioimmunoassay. The results indicate the usefulness of saliva as a noninvasive steroid measure and that steroids in the saliva of chimpanzees can be accurately measured by LC-MS/MS.

  2. [Determination of 25 quinolones in cosmetics by liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Lin, Li; Zhang, Yi; Tu, Xiaoke; Xie, Liqi; Yue, Zhenfeng; Kang, Haining; Wu, Weidong; Luo, Yao

    2015-03-01

    An analytical method was developed for the simultaneous determination of 25 quinolones, including danofloxacin mesylate, enrofloxacin, flumequine, oxloinic acid, ciprofloxacin, sarafloxacin, nalidixic acid, norfloxacin, and ofloxacin etc in cosmetics using direct extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). Cosmetic sample was extracted by acidified acetonitrile, defatted by n-hexane and separated on Poroshell EC-C18 column with gradient elution program using acetonitrile and water (both containing 0. 1% formic acid) as the mobile phases and analyzed by LC-ESI-MS/MS under the positive mode using multiple reaction monitoring (MRM). The interference of matrix was reduced by the matrix-matched calibration standard curve. The method showed good linearities over the range of 1-200 mg/kg for the 25 quinolones with good linear correlation coefficients (r ≥ 0.999). The method detection limit of the 25 quinolones was 1.0 mg/kg, and the recoveries of all analytes in lotion, milky and cream cosmetics matrices ranged from 87.4% to 105% at the spiked levels of 1, 5 and 10 mg/kg with the relative standard deviations (RSD) of 4.54%-19.7% (n = 6). The results indicated that this method is simple, fast and credible, and suitable for the simultaneous determination of the quinolones in the above three types of cosmetics.

  3. Presence of phthalate esters in intravenous solution evaluated using gas chromatography-mass spectrometry method.

    Science.gov (United States)

    Strac, Ivona Vidić; Pušić, Maja; Gajski, Goran; Garaj-Vrhovac, Vera

    2013-03-01

    Di-(2-ethylhexyl) phthalate (DEHP) is a plasticizer widely used in the production of poly-(vinyl) chloride (PVC) materials. It is a reproductive and developmental toxicant in animals and a suspected endocrine modulator in humans. DEHP is not covalently bound within the PVC molecule, which is why migration into a suitable medium can be expected. Since application of infusion solutions is one of the most common medical treatments, the objective of this study was to determine the migration of phthalates from softened PVC storage bags into infusion solution in different time periods within one year from date of production using a gas chromatography-mass spectrometry method. The measured values of DEHP ranged between 0.22 and 14.00 µg l(-1) , but the unexpected presence of other phthalate esters was also detected. It was concluded that values obtained in infusion solutions match the reference data and represent a minor risk for the patient. The presence of other phthalate esters leads to the conclusion that the pharmacopeic requirement for polymer cleanness was not fully met. Since phthalate esters are among the most extensively used industrial chemicals and are widely distributed in the environment, special precautions and further monitoring should be conducted to minimize any possible health risks. PMID:22034089

  4. Headspace Analysis of Philippine Civet Coffee Beans Using Gas Chromatography-Mass Spectrometry and Electronic Nose

    Science.gov (United States)

    Ongo, E.; Sevilla, F.; Antonelli, A.; Sberveglieri, G.; Montevecchi, G.; Sberveglieri, V.; de Paola, E. L.; Concina, I.; Falasconi, M.

    2011-11-01

    Civet coffee, the most expensive and best coffee in the world, is an economically important export product of the Philippines. With a growing threat of food adulteration and counterfeiting, a need for quality authentication is essential to protect the integrity and strong market value of Philippine civet coffee. At present, there is no internationally accepted method of verifying whether a bean is an authentic civet coffee. This study presented a practical and promising approach to identify and establish the headspace qualitative profile of Philippine civet coffee using electronic nose (E-nose) and gas chromatography-mass spectrometry (GC-MS). E-nose analysis revealed that aroma characteristic is one of the most important quality indicators of civet coffee. The findings were supported by GC-MS analysis. Principal component analysis (PCA) exhibited a clearly separated civet coffees from their control beans. The chromatographic fingerprints indicated that civet coffees differed with their control beans in terms of composition and concentration of individual volatile constituents.

  5. Metabolism profiles of nuciferine in rats using ultrafast liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Ye, Lin-Hu; Xiao, Bing-Xin; Liao, Yong-Hong; Liu, Xin-Min; Pan, Rui-Le; Chang, Qi

    2016-08-01

    Nuciferine (NF) is one of the main aporphine alkaloids existing in the traditional Chinese medicine Folium Nelumbinis (lotus leaves). Modern pharmacological studies have demonstrated that NF has a broad spectrum of bioactivities, such as anti-HIV and anti-hyperlipidemic effects, and has been recommended as a leading compound for new drug development. However, the metabolites and biotransformation pathway of NF in vivo have not yet been comprehensively investigated. The present study was performed to identify the metabolites of NF for exploring in vivo fates. Rat plasma and urine samples were collected after oral administration and prepared by liquid-liquid extraction with ethyl acetate. A method based on ultrafast liquid chromatography with tandem mass spectrometry was applied to identify the metabolites. Q1 (first quadrupole) full scan combined with a multiple reaction monitoring (MRM) survey scan were used for the detection of metabolites. MRM-information-dependent acquisition of enhanced product ions was used for the structural identification of detected metabolites. A total of 10 metabolites were identified, including phase I (demethylation, oxidation and dehydrogenation) and phase II (glucuronidation, sulfation and glutathione) biotransformation products. Demethylation is the main metabolic pathway of NF in the body. These results can help in improving understanding of the disposition and pharmacological mechanism of NF in the body. Copyright © 2016 John Wiley & Sons, Ltd. PMID:26682724

  6. Comparison of motor oils using high-temperature gas chromatography-mass spectrometry.

    Science.gov (United States)

    Reardon, Michelle R; Allen, Lance; Bender, Edward C; Boyle, Katherine M

    2007-05-01

    The analysis of motor oils has wide applications in the forensic science field from comparing lubricants transferred between an automobile and a victim or crime scene to differentiating the compositions of plastic explosives. In this study, 40 unused motor oils were analyzed and compared by high-temperature gas chromatography-mass spectrometry to determine the potential for oil individualization. Oil samples were also collected from the crankcase dipsticks of 30 cars. Twenty-six of these oils could be differentiated from each other based on visual comparisons of the unresolved envelope (baseline rise due to incomplete separation) and the resolved hydrocarbons in the raw total ion chromatograms (TICs) and smoothed TIC data. Four of these oils were analyzed as unknowns and were correctly related to the corresponding vehicle. The use of extracted ion profiles (EIPs) was explored as a means to further discriminate between the indistinct samples based on the polycyclic aromatic hydrocarbon (PAH) content. The research discussed in this paper demonstrated that differentiation of motor oils was possible by examining the TIC, smoothed TIC, and EIP data. PMID:17456092

  7. Selective extraction and determination of neonicotinoid insecticides in wine by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Rodríguez-Cabo, T; Casado, J; Rodríguez, I; Ramil, M; Cela, R

    2016-08-19

    A simplified, high throughput procedure for the determination of five neonicotinoid insecticides in red and white wines, using liquid chromatography (LC)-tandem mass spectrometry (MS/MS), is presented. The effects of different experimental parameters (extraction sorbent, solvent elution and clean-up conditions) in the efficiency and the selectivity of the sample preparation process were assessed through calculation of the extraction yields and the matrix effects (MEs). Wines (10mL) were concentrated using OASIS HLB cartridges, on-line connected to Florisil clean-up cartridges, with acetonitrile serving as the elution solvent. The extract (5mLvol) was concentrated to 1mL and injected in the LC-ESI-MS/MS system. The optimized procedure provided quantitative extraction yields at the same time that the efficiency of ESI ionization remained unchanged between standards and sample extracts. Overall recoveries, calculated against authentic standards in ACN, varied between 77 and 119% and the attained limits of quantification remained below 0.2ngmL(-1). Analysis of commercial wines revealed imidacloprid residues in more than 50% of processed samples, with a maximum level of 14ngmL(-1). PMID:27425763

  8. Systematic Optimization of Long Gradient Chromatography Mass Spectrometry for Deep Analysis of Brain Proteome

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hong; Yang, Yanling; Li, Yuxin; Bai, Bing; Wang, Xusheng; Tan, Haiyan; Liu, Tao; Beach, Thomas G.; Peng, Junmun; Wu, Zhiping

    2015-02-06

    Development of high resolution liquid chromatography (LC) is essential for improving the sensitivity and throughput of mass spectrometry (MS)-based proteomics. Here we present systematic optimization of a long gradient LC-MS/MS platform to enhance protein identification from a complex mixture. The platform employed an in-house fabricated, reverse phase column (100 μm x 150 cm) coupled with Q Exactive MS. The column was capable of achieving a peak capacity of approximately 700 in a 720 min gradient of 10-45% acetonitrile. The optimal loading level was about 6 micrograms of peptides, although the column allowed loading as many as 20 micrograms. Gas phase fractionation of peptide ions further increased the number of peptide identification by ~10%. Moreover, the combination of basic pH LC pre-fractionation with the long gradient LC-MS/MS platform enabled the identification of 96,127 peptides and 10,544 proteins at 1% protein false discovery rate in a postmortem brain sample of Alzheimer’s disease. As deep RNA sequencing of the same specimen suggested that ~16,000 genes were expressed, current analysis covered more than 60% of the expressed proteome. Further improvement strategies of the LC/LC-MS/MS platform were also discussed.

  9. Analysis of volatile compounds of Malaysian Tualang (Koompassia excelsa) honey using gas chromatography mass spectrometry.

    Science.gov (United States)

    Nurul Syazana, M S; Gan, S H; Halim, A S; Shah, Nurul Syazana Mohamad; Gan, Siew Hua; Sukari, Halim Ahmad

    2013-01-01

    The constituents of honey's volatile compounds depend on the nectar source and differ depending on the place of origin. To date, the volatile constituents of Tualang honey have never been investigated. The objective of this study was to analyze the volatile compounds in local Malaysian Tualang honey. A continuous extraction of Tualang honey using five organic solvents was carried out starting from non-polar to polar solvents and the extracted samples were analysed using gas chromatography-mass spectrometry (GC-MS). Overall, 35 volatile compounds were detected. Hydrocarbons constitute 58.5% of the composition of Tualang honey. Other classes of chemical compounds detected included acids, aldehydes, alcohols, ketones, terpenes, furans and a miscellaneous group. Methanol yielded the highest number of extracted compounds such as acids and 5-(Hydroxymethyl) furfural (HMF). This is the first study to describe the volatile compounds in Tualang honey. The use of a simple one tube, stepwise, non-thermal liquid-liquid extraction of honey is a advantageous as it prevents sample loss. Further research to test the clinical benefits of these volatile compounds is recommended.

  10. Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Baxter, Douglas C; Faarinen, Mikko; Österlund, Heléne; Rodushkin, Ilia; Christensen, Morten

    2011-09-01

    A method for the determination of methylmercury in plasma and serum samples was developed. The method uses isotope dilution with (198)Hg-labeled methylmercury, extraction into dichloromethane, back-extraction into water, aqueous-phase ethylation, purge and trap collection, thermal desorption, separation by gas chromatography, and mercury isotope specific detection by inductively coupled plasma mass spectrometry. By spiking 2 mL sample with 1.2 ng tracer, measurements in a concentration interval of (0.007-2.9) μg L(-1) could be performed with uncertainty amplification factors levels of 0.14 μg L(-1), 0.35 μg L(-1) and 2.8 μg L(-1), with recoveries in the range 82-110%. Application of the method to 50 plasma/serum samples yielded a median (mean; range) concentration of methylmercury of 0.081 (0.091; methylmercury has been directly measured in this kind of specimen, and is therefore the first estimate of a reference range.

  11. Metabolic Profiling and Quantification of Neurotransmitters in Mouse Brain by Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Jäger, Christian; Hiller, Karsten; Buttini, Manuel

    2016-01-01

    Metabolites are key mediators of cellular functions, and have emerged as important modulators in a variety of diseases. Recent developments in translational biomedicine have highlighted the importance of not looking at just one disease marker or disease inducing molecule, but at populations thereof to gain a global understanding of cellular function in health and disease. The goal of metabolomics is the systematic identification and quantification of metabolite populations. One of the most pressing issues of our times is the understanding of normal and diseased nervous tissue functions. To ensure high quality data, proper sample processing is crucial. Here, we present a method for the extraction of metabolites from brain tissue, their subsequent preparation for non-targeted gas chromatography-mass spectrometry (GC-MS) measurement, as well as giving some guidelines for processing of raw data. In addition, we present a sensitive screening method for neurotransmitters based on GC-MS in selected ion monitoring mode. The precise multi-analyte detection and quantification of amino acid and monoamine neurotransmitters can be used for further studies such as metabolic modeling. Our protocol can be applied to shed light on nervous tissue function in health, as well as neurodegenerative disease mechanisms and the effect of experimental therapeutics at the metabolic level. © 2016 by John Wiley & Sons, Inc. PMID:27584556

  12. Determination of Phytochelatins in Rice by Stable Isotope Labeling Coupled with Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Liu, Ping; Cai, Wen-Jing; Yu, Lei; Yuan, Bi-Feng; Feng, Yu-Qi

    2015-07-01

    A highly sensitive method was developed for the detection of phytochelatins (PCs) in rice by stable isotope labeling coupled with liquid chromatography-electrospray ionization-tandem mass spectrometry (IL-LC-ESI-MS/MS) analysis. A pair of isotope-labeling reagents [ω-bromoacetonylquinolinium bromide (BQB) and BQB-d(7)] were used to label PCs in plant sample and standard PCs, respectively, and then combined prior to LC/MS analysis. The heavy labeled standards were used as the internal standards for quantitation to minimize the matrix and ion suppression effects in MS analysis. In addition, the ionization efficiency of PCs was greatly enhanced through the introduction of a permanent charged moiety of quaternary ammonium of BQB into PCs. The detection sensitivities of PCs upon BQB labeling improved by 14-750-fold, and therefore, PCs can be quantitated using only 5 mg of plant tissue. Furthermore, under cadmium (Cd) stress, we found that the contents of PCs in rice dramatically increased with the increased concentrations and treatment time of Cd. It was worth noting that PC5 was first identified and quantitated in rice tissues under Cd stress in the current study. Taken together, this IL-LC-ESI-MS/MS method demonstrated to be a promising strategy in detection of PCs in plants with high sensitivity and reliability.

  13. Measurement of phthalates diesters in food using gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Cariou, Ronan; Larvor, Frédéric; Monteau, Fabrice; Marchand, Philippe; Bichon, Emmanuelle; Dervilly-Pinel, Gaud; Antignac, Jean-Philippe; Le Bizec, Bruno

    2016-04-01

    An analytical strategy dedicated to 4 major phthalate diesters (DiBP, DnBP, BBzP and DEHP) monitoring in food items has been developed and validated according to normalized guidelines. The method has been applied to a wide range of foodstuffs (n=54) to generate first-ever occurrence data at the French level. This method involves separation and detection using gas chromatography coupled to tandem mass spectrometry, in electron ionisation with highly specific selected reaction monitoring, quantification being performed according to the isotope dilution principle. A particular attention has been paid to background contamination management at any stage of the analytical process, from the sampling to the expression of the results. Limits of reporting, defined as statistically different from background contamination, were found to be 2.7, 0.53, 0.18 and 3.4 μg kg(-1), and relative combined uncertainties were finally found to be 7.6%, 12.2%, 12.0% and 14.1%, for DiBP, DnBP, BBzP and DEHP, respectively.

  14. Liquid chromatography quadrupole time-of-flight mass spectrometry selective determination of ochratoxin A in wine.

    Science.gov (United States)

    Rodríguez-Cabo, T; Rodríguez, I; Ramil, M; Cela, R

    2016-05-15

    The performance of liquid chromatography quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) for ochratoxin A (OTA) determination in wine is evaluated for the first time. Sample preparation was optimized to obtain quantitative recoveries at the same time that the efficiency of electrospray ionization (ESI) remained unaltered between sample extracts and calibration standards. Under final conditions, samples (20 mL) were concentrated using a reversed-phase solid-phase extraction (SPE) cartridge, followed by OTA elution with 1 mL of ethyl acetate. The absolute recoveries of the method, established against calibration standards, were 91-121% and 90-113% (without and with internal standard correction, respectively), for wines fortified at 3 concentration levels. The attained LOQ (0.05 ng mL(-1)) remained below the maximum permitted OTA concentration (2 ng mL(-1)) in dry wines. The method was applied to different samples, with OTA being found in some dessert wines at concentrations below 1 ng mL(-1). The ethyl ester of OTA (OTC) could be identified in the same wine samples from its accurate full product ion spectra.

  15. Quantitation of Thioprolines in Grape Wine by Isotope Dilution-Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Liu, Jingjing; Meng, Xiangpeng; Chan, Wan

    2016-02-17

    Cysteine reacts with reactive carbonyls to form thioprolines, which have been demonstrated to possess various pharmaceutical properties. Therefore, thioproline formation is considered as a major detoxification pathway for carcinogenic reactive carbonyls. In this study, we report the initial identification of thiazolidine-4-carboxylic acid (1) and 2-methylthiazolidine-4-carboxylic acid (2), two very common thioprolines, formed by reacting formaldehyde and acetaldehyde with cysteine in grape wine samples. We have developed an isotope dilution-liquid chromatography-tandem mass spectrometry method featuring high sensitivity (limit of detection of ≤1.5 ng/mL) and selectivity to quantitate compounds 1 and 2. The method after validated to be highly accurate (recovery of ≥92%) and precise [intraday relative standard deviation (RSD) of ≤4.1% and interday RSD of ≤9.7%] was applied to determine the varying compound 1 and 2 contents in grape wine samples. Results revealed the grape type and storage duration-dependent formation of thioprolines in grape wines. Overall, the results are expected to facilitate compound-dependent investigations of the health benefits of grape wine, and our findings could be adopted to predict the age of grape wine.

  16. [Determination of clavulanic acid residue in milk by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Yang, Gang; Huang, Xianhui; Guo, Chunna; Fang, Qiuhua; He, Limin

    2012-06-01

    An analytical method was developed for the determination of clavulanic acid (CLAV) in milk by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). A 2 g milk sample was deproteinized by ethanol. The supernatant was transferred into a pear-shaped bottle to be evaporated to about 0.5 mL, and the residue was dissolved with ammonium acetate solution. The sample was determined by HPLC-MS/MS after the purification. The chromatographic separation was achieved on a Luna 5u C8 column using 0.1% formic acid in water and acetonitrile as mobile phases with gradient elution. The identification of CLAV was carried out by MS/MS equipped with electrospray ionization in negative scanning and multiple reaction monitoring (MRM) modes. Matrix-matched calibration standard was used for the quantification. The calibration curve showed perfect linear in the range of 10 - 400 microg/kg with the correlation coefficient of 0.999. The limit of detection (LOD, S/N > or = 3) was 10 microg/kg in milk, and the limit of quantification (LOQ, S/N > or = 10) was 20 microg/kg. The mean recoveries varied from 80.00% to 91.25% at the four spiked levels of LOQ, 1/2MRL (the maximum residue limit), MRL, and 2MRL with the relative standard deviations of 5.60% -8.77%. In conclusion, the established method can be applied for the determination of CLAV residues in milk.

  17. Simultaneous liquid chromatography-mass spectrometry quantification of cefixime and clavulanic acid in human plasma.

    Science.gov (United States)

    Dubala, Anil; Nagarajan, Janaki Sankarachari Krishnan; Vimal, Chandran Sathish; George, Renjith

    2015-01-01

    A simple and specific liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS) assay method has been developed and fully validated for the simultaneous quantification of cefixime (CX) and clavulanic acid (CA) in human plasma. Analytes and internal standard were extracted from human plasma by a solid phase extraction technique using a Sam prep (3 mL, 100 mg) extraction cartridge. The extracted samples were chromatographed on a reverse phase C18 column using a mixture of methanol : acetonitrile : 2 mM ammonium acetate (pH 3.5) (25 : 25 : 50, v/v/v) as the mobile phase at a flow rate of 0.8 mL/min. Quantification of the analytes were carried out using single quadrupole LC-APCI-MS through selected ion monitoring at m/z 452 and 198, respectively, for CX and CA. The assay was linear over the concentration range of 0.05-10.0 and 0.1-10.0 μg/mL, respectively, for CX and CA. The mean plasma extraction recoveries of the CX and CA were found to be 95.20-96.27% and 94.67-95.58%, respectively. The method was successfully applied for the determination of pharmacokinetics of CX and CA after oral administration of single dosage CX/CA (200/125 mg) pill to the humans (n = 12).

  18. Comprehensive characterization of anticoagulant rodenticides in sludge by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Gómez-Canela, Cristian; Lacorte, Silvia

    2016-08-01

    The occurrence of 10 commonly used anticoagulant rodenticides in centrifuged sludge of 27 wastewater treatment plants was evaluated using solid-liquid extraction (SLE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Activated carbon, alumina, and Florisil cartridges with methanol/dichloromethane as eluting solvents were tested in combination with primary-secondary amine (PSA) to optimize an efficient sample cleanup. PSA in combination with Florisil was the best methodology to extract anticoagulant rodenticides in sludge providing recoveries between 42 ± 0.5 and 100 ± 2 %. Warfarin, bromadiolone, ferulenol, and coumachlor were the most ubiquitous compounds in sludge at concentrations up to 84.2 ng g(-1) for the latter. Coumatetralyl, dicoumarol, and brodifacoum were detected sporadically at levels between 6.1 and 17.4 ng g(-1). On the contrary, acenocoumarol, difenacoum, and flocoumafen were not detected in any sample. Finally, we estimated the amount of anticoagulant rodenticides discharged via sludge in order to determine the potential impact to agricultural soil according to different sludge usage practices in the region investigated. This study demonstrates that anticoagulant rodenticides are accumulated in sludge during activated sludge treatment and that the application of sludge as fertilizers may pose a future environmental risk, if not controlled. PMID:27146526

  19. Endogenous glucocorticoid analysis by liquid chromatography-tandem mass spectrometry in routine clinical laboratories.

    Science.gov (United States)

    Hawley, James M; Keevil, Brian G

    2016-09-01

    Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a powerful analytical technique that offers exceptional selectivity and sensitivity. Used optimally, LC-MS/MS provides accurate and precise results for a wide range of analytes at concentrations that are difficult to quantitate with other methodologies. Its implementation into routine clinical biochemistry laboratories has revolutionised our ability to analyse small molecules such as glucocorticoids. Whereas immunoassays can suffer from matrix effects and cross-reactivity due to interactions with structural analogues, the selectivity offered by LC-MS/MS has largely overcome these limitations. As many clinical guidelines are now beginning to acknowledge the importance of the methodology used to provide results, the advantages associated with LC-MS/MS are gaining wider recognition. With their integral role in both the diagnosis and management of hypo- and hyperadrenal disorders, coupled with their widespread pharmacological use, the accurate measurement of glucocorticoids is fundamental to effective patient care. Here, we provide an up-to-date review of the LC-MS/MS techniques used to successfully measure endogenous glucocorticoids, particular reference is made to serum, urine and salivary cortisol. PMID:27208627

  20. Data preprocessing method for liquid chromatography-mass spectrometry based metabolomics.

    Science.gov (United States)

    Wei, Xiaoli; Shi, Xue; Kim, Seongho; Zhang, Li; Patrick, Jeffrey S; Binkley, Joe; McClain, Craig; Zhang, Xiang

    2012-09-18

    A set of data preprocessing algorithms for peak detection and peak list alignment are reported for analysis of liquid chromatography-mass spectrometry (LC-MS)-based metabolomics data. For spectrum deconvolution, peak picking is achieved at the selected ion chromatogram (XIC) level. To estimate and remove the noise in XICs, each XIC is first segmented into several peak groups based on the continuity of scan number, and the noise level is estimated by all the XIC signals, except the regions potentially with presence of metabolite ion peaks. After removing noise, the peaks of molecular ions are detected using both the first and the second derivatives, followed by an efficient exponentially modified Gaussian-based peak deconvolution method for peak fitting. A two-stage alignment algorithm is also developed, where the retention times of all peaks are first transferred into the z-score domain and the peaks are aligned based on the measure of their mixture scores after retention time correction using a partial linear regression. Analysis of a set of spike-in LC-MS data from three groups of samples containing 16 metabolite standards mixed with metabolite extract from mouse livers demonstrates that the developed data preprocessing method performs better than two of the existing popular data analysis packages, MZmine2.6 and XCMS(2), for peak picking, peak list alignment, and quantification.

  1. Surface-sampling and analysis of TATP by swabbing and gas chromatography/mass spectrometry.

    Science.gov (United States)

    Romolo, Francesco Saverio; Cassioli, Luigi; Grossi, Silvana; Cinelli, Giuseppe; Russo, Mario Vincenzo

    2013-01-10

    The method of sample recovery for trace detection and identification of explosives plays a critical role in several criminal investigations. After bombing, there can be difficulties in sending big objects to a laboratory for analysis. Traces can also be searched for on large surfaces, on hands of suspects or on surfaces where the explosive was placed during preparatory phases (e.g. places where an IED was assembled, vehicles used for transportation, etc.). In this work, triacetone triperoxide (TATP) was synthesized from commercial precursors following reported methods. Several portions of about 6mg of TATP were then spread on different surfaces (e.g. floors, tables, etc.) or used in handling tests. Three different swabbing systems were used: a commercial swab, pre-wetted with propan-2-ol (isopropanol) and water (7:3), dry paper swabs, and cotton swabs wetted with propan-2-ol. Paper and commercial swabs were also used to sample a metal plate, where a small charge of about 4g of TATP was detonated. Swabs were sealed in small glass jars with screw caps and Parafilm(®) M and sent to the laboratory for analysis. Swabs were extracted and analysed several weeks later by gas chromatography/mass spectrometry. All the three systems gave positive results, but wetted swabs collected higher amounts of TATP. The developed procedure showed its suitability for use in real cases, allowing TATP detection in several simulations, including a situation in which people wash their hands after handling the explosive.

  2. Quantification of busulfan in plasma by gas chromatography-mass spectrometry following derivatization with tetrafluorothiophenol.

    Science.gov (United States)

    Quernin, M H; Poonkuzhali, B; Montes, C; Krishnamoorthy, R; Dennison, D; Srivastava, A; Vilmer, E; Chandy, M; Jacqz-Aigrain, E

    1998-05-01

    A specific and highly sensitive method has been developed for the determination of busulfan in plasma by gas chromatography-mass spectrometry using a deuterium-labeled busulfan (busulfan-d8) as internal standard. Plasma containing busulfan and busulfan-d8 were extracted with ethyl acetate and derivatized with 2,3,5,6-tetrafluorothiophenol prior to the monitoring of specific ions. The limit of quantification of the assay was 20 ng/ml and the calibration curve was linear over the range of 10 to 2000 ng/ml of derivatized busulfan. This method was in good agreement with the GC-MS assay using derivatization with sodium iodide and measuring diiodobutane. In addition, a pharmacokinetic study of busulfan was conducted in six children. The apparent oral clearance was 5.7+/-1.9 ml/kg/min and the volume of distribution was 1.0+/-0.4 l/kg and were similar to those previously reported in pediatric patients.

  3. Confirmatory analysis of firocoxib in bovine milk by rapid resolution liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Dowling, Geraldine; Gallo, Pasquale; Regan, Liam

    2009-02-15

    A rapid method has been developed to analyse for firocoxib (FIRO) residue in bovine milk. Milk samples were extracted with acetonitrile and sample extracts were purified on Evolute ABN solid phase extraction cartridges. Aliquots were analysed by rapid resolution liquid chromatography tandem mass spectrometry (RRLC-MS/MS). The method was validated in bovine milk, according to the criteria defined in Commission Decision 2002/657/EC. The decision limit (CCalpha) was 1.18ng/mL and for the detection capability a (CCbeta) value of 2.02ng/mL was obtained. The measurement uncertainty of the method was 27%. Fortifying bovine milk samples (n=18) in three separate assays, show the accuracy of the method to be between 96 and 105%. The precision of the method, expressed as RSD values for the within-lab reproducibility at the three levels of fortification (5, 7.5 and 10ng/mL) was less than 11% respectively. PMID:19179123

  4. Identification of Floral Scent in Chrysanthemum Cultivars and Wild Relatives by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Hainan Sun

    2015-03-01

    Full Text Available The objective of this study was to identify the major volatile compounds and their relative concentrations in flowers of different chrysanthemum cultivars and their wild relatives. The volatile organic components of fresh flowers were analyzed using a headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry. In total, 193 volatile organic components were detected; the major scent components were monoterpenoids and oxygenated monoterpenoids, which accounted for 68.59%–99.93% of the total volatiles in all tested materials except for Chrysanthemum indicum collected from Huangshan, in which they accounted for only 37.45% of total volatiles. The major volatile compounds were camphor, α-pinene, chrysanthenone, safranal, myrcene, eucalyptol, 2,4,5,6,7,7ab-hexahydro-1H-indene, verbenone, β-phellandrene and camphene. In a hierarchical cluster analysis, 39 accessions of Chrysanthemum and its relatives formed six clusters based on their floral volatile compounds. In a principal component analysis, only spider type flowers were located closely on the score plot. The results of this study provide a basis for breeding chrysanthemum cultivars which desirable floral scents.

  5. Multi-class method for biomonitoring of hair samples using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Martín, Julia; Möder, Monika; Gaudl, Alexander; Alonso, Esteban; Reemtsma, Thorsten

    2015-11-01

    Currently, non-invasive biomonitoring of human exposure to organic pollutants bases upon the analysis mainly of urine and human breast milk. While mostly persistent organic pollutants are the center of interest, the aim of our study was to develop a method for the determination of different chemical classes of emerging pollutants (organophosphorus flame retardants, plastic additives such as phthalates, bisphenol A, insecticides, antimicrobials, preservatives and musk fragrances) in hair by gas chromatography-mass spectrometry. The preferred sample preparation included hydrolysis of the hair with trifluoroacetic acid in methanol followed by a liquid-liquid extraction using hexane/ethyl acetate. The validated method is characterized by recoveries higher than 77 % for most analytes, relative standard deviations below 16 % and limits of detection between 2 pg mg(-1) (HHCB) and 292 pg mg(-1) (propylparaben) using 50 mg of dry hair. After respective blank corrections, bis-(2-ethylhexyl)phthalate (DEHP) and the musk fragrance HHCB were the predominant compounds determined in all hair samples at concentrations between 32 and 59 ng mg(-1) and 0.8-13 ng mg(-1), respectively. The bactericide triclosan and the insect repellent N,N-diethyl-3-methylbenzamide (DEET) were detected in selected hair samples at 2 and 0.8 ng mg(-1), respectively.

  6. Hydrocarbon phenotyping of algal species using pyrolysis-gas chromatography mass spectrometry

    Directory of Open Access Journals (Sweden)

    Kothari Shankar L

    2010-05-01

    Full Text Available Abstract Background Biofuels derived from algae biomass and algae lipids might reduce dependence on fossil fuels. Existing analytical techniques need to facilitate rapid characterization of algal species by phenotyping hydrocarbon-related constituents. Results In this study, we compared the hydrocarbon rich algae Botryococcus braunii against the photoautotrophic model algae Chlamydomonas reinhardtii using pyrolysis-gas chromatography quadrupole mass spectrometry (pyGC-MS. Sequences of up to 48 dried samples can be analyzed using pyGC-MS in an automated manner without any sample preparation. Chromatograms of 30-min run times are sufficient to profile pyrolysis products from C8 to C40 carbon chain length. The freely available software tools AMDIS and SpectConnect enables straightforward data processing. In Botryococcus samples, we identified fatty acids, vitamins, sterols and fatty acid esters and several long chain hydrocarbons. The algae species C. reinhardtii, B. braunii race A and B. braunii race B were readily discriminated using their hydrocarbon phenotypes. Substructure annotation and spectral clustering yielded network graphs of similar components for visual overviews of abundant and minor constituents. Conclusion Pyrolysis-GC-MS facilitates large scale screening of hydrocarbon phenotypes for comparisons of strain differences in algae or impact of altered growth and nutrient conditions.

  7. [Identification of Kweichow Moutai liquor by gas chromatography-mass spectrometry fingerprint].

    Science.gov (United States)

    Sun, Qiran; Xiang, Ping; Shen, Baohua; Shen, Min

    2010-09-01

    The fingerprint of Kweichow Moutai liquor was established by gas chromatography-mass spectrometry (GC-MS) and the similarity of fingerprints was evaluated by the fingerprint similarity calculation software designed by Zhejiang University based on included angle cosine. One milliliter of liquor sample was mixed with ten microliter of 2% n-pentyl acetate solution used as internal standard. One microliter of the prepared sample was injected into a GC-MS. The separation was performed on an HP-INNOWAX 19091N-113 capillary column. The precision and repeatability of the method were good as the relative standard deviation (RSD) of intrabatch was less than 5%. A total of 35 characteristic components of Kweichow Moutai liquor were identified. The fingerprints of 38 batches of Kweichow Moutai, 5 Moutai-flavor liquors produced by Kweichow Moutai Company Limited, the same manufacturer as Kweichow Moutai, and 12 other brand liquors were compared in characteristic components and similarity. The results demonstrated that different batches of Kweichow Moutai had good similarity (> or = 0.9), and Kweichow Moutai was differentiated from the liquors of different alcohol contents and flavors, but it was poorly distinguished from the Moutai-flavor liquors by fingerprint similarity calculation software. Therefore, only in combining characteristic components and fingerprint similarity results, Kweichow Moutai can be distinguished from other liquors. The established method offers technical basis for the identification of Kweichow Moutai. PMID:21171278

  8. Multiresidue analysis of environmental pollutants in edible vegetable oils by gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Rui-Ze; Jiang, Jie; Mao, Ting; Zhao, Ya-Song; Lu, Yong

    2016-09-15

    A novel multiresidue determination of polycyclic aromatic hydrocarbons (PAHs), phthalate esters (PAEs) and alkylphenols (APs) in edible vegetable oils was developed. The samples were extracted with hexane-saturated acetonitrile, and after concentration, the extract was directly qualitatively and quantitatively analyzed by gas chromatography-tandem mass spectrometry (GC-MS/MS) with multiple reaction monitoring (MRM) in positive ion mode. The calibration curve displayed good linearity in the range of 2-100μg/L, with correlation coefficients greater than 0.99. The mean recoveries were 70.0-110.8% by analysis of spiked oil, and the relative standard deviations (RSDs) were 2.1-10.2% (n=6), respectively. The limits of detection (LODs) for the 23 PAHs, 17 PAEs and 3 APs were 0.1-1.0μg/kg, 0.1-4.0μg/kg and 1.2-3.0μg/kg, respectively. The established method effectively avoided interference from large amounts of lipids and pigments. It was applied to real sample and shown to be a rapid and reliable alternative for determination and confirmation in routine analysis. PMID:27080878

  9. [Determination of gossypol in edible vegetable oil with high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Zhang, Wenhua; Huang, Chaoqun; Xie, Wen; Shen, Li

    2014-06-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of gossypol in edible vegetable oil. The sample was extracted with ethyl alcohol by vortex-excited oscillation. The extract was cleaned up by 0.22 microm filter membrane and centrifuged for 5 min at 4 000 r/min after standing in a fridge at 4 degrees C for 30 min. The compound was separated on a C18 column (100 mm x 2.1 mm, 3.5 microm) with acetonitrile and 1% (v/v) formic acid aqueous solution as mobile phase. The detection of gossypol was carried out by LC-MS/MS with positive electrospray ionization under multiple reaction monitoring (MRM) mode using external standard method. The limits of quantification (S/N > 10) of gossypol in edible vegetable oil was 1 mg/kg. The recoveries were from 87.4% to 100% at the spiked levels of 1, 2, 200 mg/kg of gossypol in edible vegetable oil with the relative standard deviations (RSDs) between 3.9% and 12.2%. The method, with high sensitivity, good precision and high recovery, was suitable for the confirmation and quantification of gossypol residue in edible vegetable oil.

  10. Determination of phthalate esters in teas and tea infusions by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Du, Liping; Ma, Lijuan; Qiao, Yang; Lu, Yan; Xiao, Dongguang

    2016-04-15

    Phthalate esters (PAEs), a group of environmental pollutants which are carcinogenic to human body, have been detected in teas. In this work, five PAEs in teas and tea infusions were quantitatively determined by a modified simultaneous distillation extraction (SDE) coupled with gas chromatography-mass spectrometry. After the optimization of SDE, the proposed method afforded a wide range of linearity and high linear regression coefficients with the limits of detection range of 0.24-3.72 μg/kg. The average recoveries were 79.83-116.67% for tea samples and 78.22-101.64% for tea infusions with all the relative standard deviations below 20%. The total content of five PAEs in teas was 1.135-3.734 mg/kg and the total dissolving ratio of five PAEs from tea to infusion was 19.05-28.07% for the selected tea samples. The risk assessment result of all the selected tea samples demonstrated that the population with the habit of drinking tea won't cause risk to human health.

  11. Antibiotic toxicity and absorption in zebrafish using liquid chromatography-tandem mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Fan Zhang

    Full Text Available Evaluation of drug toxicity is necessary for drug safety, but in vivo drug absorption is varied; therefore, a rapid, sensitive and reliable method for measuring drugs is needed. Zebrafish are acceptable drug toxicity screening models; we used these animals with a liquid chromatography-tandem mass spectrometry (LC-MS/MS method in a multiple reaction monitoring mode to quantify drug uptake in zebrafish to better estimate drug toxicity. Analytes were recovered from zebrafish homogenate by collecting supernatant. Measurements were confirmed for drugs in the range of 10-1,000 ng/mL. Four antibiotics with different polarities were tested to explore any correlation of drug polarity, absorption, and toxicity. Zebrafish at 3 days post-fertilization (dpf absorbed more drug than those at 6 h post-fertilization (hpf, and different developmental periods appeared to be differentially sensitive to the same compound. By observing abnormal embryos and LD50 values, zebrafish embryos at 6 hpf were considered to be suitable for evaluating embryotoxicity. Also, larvae at 3 dpf were adapted to measure acute drug toxicity in adult mammals. Thus, we can exploit zebrafish to study drug toxicity and can reliably quantify drug uptake with LC-MS/MS. This approach will be helpful for future studies of toxicology in zebrafish.

  12. Determination of fipronil by solid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Vílchez, J L; Prieto, A; Araujo, L; Navalón, A

    2001-06-01

    A method for the determination of trace amounts of the insecticide fipronil was developed using solid-phase microextraction-gas chromatography-mass spectrometry and selected ion monitoring. Fipronil was extracted with a fused-silica fiber coated with 85 microm polyacrylate. The effects of pH, ionic strength, sample volume, extraction and desorption times as well as the extraction temperature were studied. Lindane was used as an internal standard. The linear concentration range of application was 0.3-100 ng ml(-1) of fipronil, with a relative standard deviation of 9.5% (for a level of 50 ng ml(-1)) and a detection limit of 0.08 ng ml(-1). The method was applied to check the eventual existence of fipronil above this limit in water and soil samples from Granada (Spain) as well as in human urine samples. The method validation was completed with spiked matrix samples. The method can be applied as a monitoring tool for water, soil and urine, in the investigation of environmental and occupational exposure to fipronil.

  13. Determination of usnic acid in lichen toxic to elk by liquid chromatography with ultraviolet and tandem mass spectrometry detection.

    Science.gov (United States)

    Roach, John A G; Musser, Steven M; Morehouse, Kim; Woo, Jason Y J

    2006-04-01

    Usnic acid is unambiguously confirmed by tandem mass spectrometry (MS/MS) in tumbleweed shield lichen, Xanthoparmelia chlorochroa. The lichen contains 2% usnic acid by liquid chromatography with UV quantification at 282 nm. The UV linear range for usnic acid quantification is from its 4 ng limit of detection to 2 microg injected. UV signal saturation is recognized by distortion of the usnic acid UV spectrum. Positive ion electrospray-tandem mass spectrometry offers no similar means to recognize quantification data recorded above the linear range of electrospray. Electrospray ionization capacity and matrix effects limit the reliability of tandem mass spectrometry quantification. The combination of UV quantification and MS confirmation provides a reliable analytical method for measuring usnic acid levels in plant material. PMID:16569032

  14. A strategy for identification and structural characterization of compounds from Gardenia jasminoides by integrating macroporous resin column chromatography and liquid chromatography-tandem mass spectrometry combined with ion-mobility spectrometry.

    Science.gov (United States)

    Wang, Lu; Liu, Shu; Zhang, Xueju; Xing, Junpeng; Liu, Zhiqiang; Song, Fengrui

    2016-06-24

    In this paper, an analysis strategy integrating macroporous resin (AB-8) column chromatography and high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) combined with ion mobility spectrometry (IMS) was proposed and applied for identification and structural characterization of compounds from the fruits of Gardenia jasminoides. The extracts of G. jasminoides were separated by AB-8 resin column chromatography combined with reversed phase liquid chromatography (C18 column) and detected by electrospray ionization tandem mass spectrometry. Additionally, ion mobility spectrometry (IMS) was employed as a supplementary separation technique to discover previously undetected isomers from the fruits of G. jasminoides. A total of 71 compounds, including iridoids, flavonoids, triterpenes, monoterpenoids, carotenoids and phenolic acids were identified by the characteristic high resolution mass spectrometry and the ESI-MS/MS fragmentations. In conclusion, the IMS-MS technique achieved the separation of isomers in crocin-3 and crocin-4 according to their acquired mobility drift times differing from classical analysis by mass spectrometry. The proposed strategy can be used as a highly sensitive and efficient procedure for identification and separation isomeric components in extracts of herbal medicines.

  15. A strategy for identification and structural characterization of compounds from Gardenia jasminoides by integrating macroporous resin column chromatography and liquid chromatography-tandem mass spectrometry combined with ion-mobility spectrometry.

    Science.gov (United States)

    Wang, Lu; Liu, Shu; Zhang, Xueju; Xing, Junpeng; Liu, Zhiqiang; Song, Fengrui

    2016-06-24

    In this paper, an analysis strategy integrating macroporous resin (AB-8) column chromatography and high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) combined with ion mobility spectrometry (IMS) was proposed and applied for identification and structural characterization of compounds from the fruits of Gardenia jasminoides. The extracts of G. jasminoides were separated by AB-8 resin column chromatography combined with reversed phase liquid chromatography (C18 column) and detected by electrospray ionization tandem mass spectrometry. Additionally, ion mobility spectrometry (IMS) was employed as a supplementary separation technique to discover previously undetected isomers from the fruits of G. jasminoides. A total of 71 compounds, including iridoids, flavonoids, triterpenes, monoterpenoids, carotenoids and phenolic acids were identified by the characteristic high resolution mass spectrometry and the ESI-MS/MS fragmentations. In conclusion, the IMS-MS technique achieved the separation of isomers in crocin-3 and crocin-4 according to their acquired mobility drift times differing from classical analysis by mass spectrometry. The proposed strategy can be used as a highly sensitive and efficient procedure for identification and separation isomeric components in extracts of herbal medicines. PMID:27208986

  16. Accurate mass error correction in liquid chromatography time-of-flight mass spectrometry based metabolomics

    NARCIS (Netherlands)

    Mihaleva, V.V.; Vorst, O.F.J.; Maliepaard, C.A.; Verhoeven, H.A.; Vos, de C.H.; Hall, R.D.; Ham, van R.C.H.J.

    2008-01-01

    Compound identification and annotation in (untargeted) metabolomics experiments based on accurate mass require the highest possible accuracy of the mass determination. Experimental LC/TOF-MS platforms equipped with a time-to-digital converter (TDC) give the best mass estimate for those mass signals

  17. Application Of Dexamethasone Analysis Procedure In Pharmaceutical Product And Food Samples By Using The Liquid Chromatography Mass Spectrometry (LC-MS)

    International Nuclear Information System (INIS)

    The high pressure liquid chromatography mass spectrometry method for determination of dexamethasone has been studied. The authors have some results in found the optimal conditions in high pressure liquid chromatography mass spectrometry system for applications analysis of dexamethasone such as flow rate 0.5 ml/minute, the rate of mobile phase ACN: 0.1% HCOOH (80:20), injection volume was 20 μl. Besides, the authors analyzed a number of experimental samples with recovery range 84-96%. These initial results give the high pressure liquid chromatography mass spectrometry in operation. (author)

  18. Rapid and Accurate Identification of Animal Species in Natural Leather Goods by Liquid Chromatography/Mass Spectrometry

    Science.gov (United States)

    Izuchi, Yukari; Takashima, Tsuneo; Hatano, Naoya

    2016-01-01

    The demand for leather goods has grown globally in recent years. Industry revenue is forecast to reach $91.2 billion by 2018. There is an ongoing labelling problem in the leather items market, in that it is currently impossible to identify the species that a given piece of leather is derived from. To address this issue, we developed a rapid and simple method for the specific identification of leather derived from cattle, horses, pigs, sheep, goats, and deer by analysing peptides produced by the trypsin-digestion of proteins contained in leather goods using liquid chromatography/mass spectrometry. We determined species-specific amino acid sequences by liquid chromatography/tandem mass spectrometry analysis using the Mascot software program and demonstrated that collagen α-1(I), collagen α-2(I), and collagen α-1(III) from the dermal layer of the skin are particularly useful in species identification. PMID:27313979

  19. Rapid and Accurate Identification of Animal Species in Natural Leather Goods by Liquid Chromatography/Mass Spectrometry.

    Science.gov (United States)

    Izuchi, Yukari; Takashima, Tsuneo; Hatano, Naoya

    2016-01-01

    The demand for leather goods has grown globally in recent years. Industry revenue is forecast to reach $91.2 billion by 2018. There is an ongoing labelling problem in the leather items market, in that it is currently impossible to identify the species that a given piece of leather is derived from. To address this issue, we developed a rapid and simple method for the specific identification of leather derived from cattle, horses, pigs, sheep, goats, and deer by analysing peptides produced by the trypsin-digestion of proteins contained in leather goods using liquid chromatography/mass spectrometry. We determined species-specific amino acid sequences by liquid chromatography/tandem mass spectrometry analysis using the Mascot software program and demonstrated that collagen α-1(I), collagen α-2(I), and collagen α-1(III) from the dermal layer of the skin are particularly useful in species identification.

  20. Rapid and Accurate Identification of Animal Species in Natural Leather Goods by Liquid Chromatography/Mass Spectrometry.

    Science.gov (United States)

    Izuchi, Yukari; Takashima, Tsuneo; Hatano, Naoya

    2016-01-01

    The demand for leather goods has grown globally in recent years. Industry revenue is forecast to reach $91.2 billion by 2018. There is an ongoing labelling problem in the leather items market, in that it is currently impossible to identify the species that a given piece of leather is derived from. To address this issue, we developed a rapid and simple method for the specific identification of leather derived from cattle, horses, pigs, sheep, goats, and deer by analysing peptides produced by the trypsin-digestion of proteins contained in leather goods using liquid chromatography/mass spectrometry. We determined species-specific amino acid sequences by liquid chromatography/tandem mass spectrometry analysis using the Mascot software program and demonstrated that collagen α-1(I), collagen α-2(I), and collagen α-1(III) from the dermal layer of the skin are particularly useful in species identification. PMID:27313979

  1. Quantitative determination of terbutaline and orciprenaline in human plasma by gas chromatography/negative ion chemical ionization/mass spectrometry.

    Science.gov (United States)

    Leis, H J; Gleispach, H; Nitsche, V; Malle, E

    1990-06-01

    A method for the determination of unconjugated terbutaline and orciprenaline in human plasma is described. The assay is based on stable isotope dilution gas chromatography/negative ion chemical ionization/mass spectrometry. An inexpensive and rapid method for preparation of stable isotope labelled analogues as well as their use in quantitative gas chromatography/mass spectrometry is shown. A highly efficient sample work-up procedure with product recoveries of more than 95% is presented. The method developed permits quantitative measurement of terbutaline and orciprenaline in human plasma down to 100 pg ml-1, using 1 ml of sample. Plasma levels of terbutaline after oral administration of 5 mg of terbutaline sulphate were estimated. PMID:2357489

  2. Measurement of pyrethroid, organophosphorus, and carbamate insecticides in human plasma using isotope dilution gas chromatography-high resolution mass spectrometry.

    Science.gov (United States)

    Pérez, José J; Williams, Megan K; Weerasekera, Gayanga; Smith, Kimberly; Whyatt, Robin M; Needham, Larry L; Barr, Dana Boyd

    2010-10-01

    We have developed a gas chromatography-high resolution mass spectrometry method for measuring pyrethroid, organophosphorus, carbamate and fipronil pesticides and the synergist piperonyl butoxide in human plasma. Plasma samples were extracted using solid phase extraction and were then concentrated for injection and analysis using isotope dilution gas chromatography-high resolution mass spectrometry. The limits of detection ranged from 10 to 158 pg/mL with relative recoveries at concentrations near the LODs (e.g., 25 or 250 pg/mL) ranging from 87% to 156% (9 of the 16 compounds were within ±15% of 100%). The extraction recoveries ranged from 20% to 98% and the overall method relative standard deviations were typically less than 20% with some exceptions. Analytical characteristics were determined at 25, 250, and 1000 pg/mL.

  3. Characterization of Fumonisin A-Series by High-Resolution Liquid Chromatography-Orbitrap Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Masayoshi Tamura

    2014-08-01

    Full Text Available Fumonisin A-series (FAs in a reference material of corn sample that was naturally contaminated with fumonisins was characterized using high-resolution liquid chromatography-Orbitrap mass spectrometry (LC-Orbitap MS. Peaks for fumonisin B1 (FB1, fumonisin B2 (FB2, and fumonisin B3 (FB3, in addition to three peaks corresponding to unknown compounds I, II, and III, were detected in the chromatogram for the corn sample. Fragment ion analysis for FB1, FB2, and FB3 showed that while the ions formed at m/z values of 200–800 were similar to those formed by the cleavage of the tricarballylic acids and the hydroxyl groups, the fragmentation patterns at m/z values of 50–200 varied depending on the hydroxyl group locations in the compounds. Fragment ion analysis of compounds I–III revealed structural similarities to FBs, only differing by an additional C2H2O in the unknown compounds. Using these results and by comparing the product ion mass spectra of compound I with fumonisin A1 (FA1 synthesized from FB1 standards, compounds I–III were hypothesized to be N-acetyl analogs of FBs: fumonisins A1 (FA1, A2 (FA2, and A3 (FA3. The method for determining concentrations was validated with FA1, FB1, FB2, and FB3 standards and applied to analyze the reference material. The FB1, FB2, and FB3 analytical levels were within acceptance limits and the amount of FA1 in the material was ~15% of FB1 amount at 4.2 mg/kg.

  4. Measurement of hydroxysafflor yellow A in human urine by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Li, Chang-Yin; Chu, Ji-Hong; Zhang, Jun; Sun, Bing-Ting; Dai, Guo-Liang; Liu, Shi-Jia; Ju, Wen-Zheng

    2015-01-01

    A rapid and specific high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the quantification of hydroxysafflor yellow A (HSYA) in human urine with isorhamnetin-3-O-neohespeidoside as internal standard (IS). HSYA and IS were extracted from urine samples by simple solid-phase extraction and separated on an Agilent Zorbax SB C18 column (4.6 mm × 150 mm, 5 μm) with the mobile phase of 0.2 mM ammonium acetate: methanol (30/70, v/v) at a flow rate of 0.4 mL/min. Polar endogenous interferences eluted in 0.1-2.5 min were switched into waste channel by the Valve Valco, to reduce the possible matrix effect for MS detection in each run. The MS detection of analytes was performed on a tandem mass spectrometer equipped with an electrospray ionization source in negative mode using multiple-reaction monitoring. The MS/MS ion transitions monitored were m/z 611.3→491.2 for HSYA and m/z 623.2→299.2 for IS. The method was fully validated for selectivity, sensitivity, linearity, precision, accuracy, recovery, matrix effect and stability, and then was applied to the urinary excretion study of injectable powder of pure HSYA in healthy Chinese volunteers for the first time. The results suggested that urine was the main excretion way of HSYA in healthy volunteers, further demonstrating the feasibility and necessity of our current method. PMID:25463208

  5. Determination of bedaquiline in human serum using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Alffenaar, Jan-Willem C; Bolhuis, Mathieu; van Hateren, Kai; Sturkenboom, Marieke; Akkerman, Onno; de Lange, Wiel; Greijdanus, Ben; van der Werf, Tjip; Touw, Daan

    2015-09-01

    Bedaquiline, a diarylquinoline for the treatment of multidrug-resistant tuberculosis (TB), relies on exposure-dependent killing. As data on drug exposure in specific populations are scarce, pharmacokinetic studies may be of interest. No simple and robust validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been reported to date. Therefore, a new method using a quadrupole mass spectrometer was developed for analysis of bedaquiline and N-monodesmethyl bedaquiline (M2) in human serum, using deuterated bedaquiline as the internal standard. The calibration curve was linear over a range of 0.05 (lower limit of quantification [LLOQ]) to 6.00 mg/liter for both bedaquiline and M2, with correlation coefficient values of 0.997 and 0.999, respectively. The calculated accuracy ranged from 1.9% to 13.6% for bedaquiline and 2.9% to 8.5% for M2. Within-run precision ranged from 3.0% to 7.2% for bedaquiline and 3.1% to 5.2% for M2, and between-run precision ranged from 0.0% to 4.3% for bedaquiline and 0.0% to 4.6% for M2. Evaluation of serum concentrations in a patient receiving bedaquiline showed high levels at the end of treatment, reflecting accumulation of the drug. More observational pharmacokinetic data are needed to relate altered drug concentrations to clinical outcome or adverse drug effects. A simple LC-MS/MS method to quantify bedaquiline and M2 levels in human serum using a deuterated internal standard has been validated. This method can be used in clinical studies and daily practice. PMID:26149993

  6. Application of capillary gas chromatography mass spectrometry/computer techniques to synoptic survey of organic material in bed sediment

    Science.gov (United States)

    Steinheimer, T.R.; Pereira, W.E.; Johnson, S.M.

    1981-01-01

    A bed sediment sample taken from an area impacted by heavy industrial activity was analyzed for organic compounds of environmental significance. Extraction was effected on a Soxhlet apparatus using a freeze-dried sample. The Soxhlet extract was fractionated by silica gel micro-column adsorption chromatography. Separation and identification of the organic compounds was accomplished by capillary gas chromatography/mass spectrometry techniques. More than 50 compounds were identified; these include saturated hydrocarbons, olefins, aromatic hydrocarbons, alkylated polycyclic aromatic hydrocarbons, and oxygenated compounds such as aldehydes and ketones. The role of bed sediments as a source or sink for organic pollutants is discussed. ?? 1981.

  7. Detection of 2-eicosanol by gas chromatography-mass spectrometry in sputa from patients with pulmonary mycobacterial infections.

    OpenAIRE

    Alugupalli, S; Olsson, B; Larsson, L.

    1993-01-01

    A total of 96 sputum specimens from patients with suspected or known mycobacterial and nonmycobacterial pulmonary infections were analyzed by gas chromatography-mass spectrometry for the presence of 2-eicosanol. This secondary alcohol was detected in all of the 25 sputum specimens culture positive for Mycobacterium tuberculosis, in 7 of the 9 sputum specimens culture positive for M. avium complex, and in all 3 of the studied sputum specimens associated with M. malmoense. The alcohol was not d...

  8. Elucidation and identification of amino acid containing membrane lipids using liquid chromatography/high-resolution mass spectrometry

    OpenAIRE

    Moore, E.K.; Hopmans, E.C.; Rijpstra, W.I.C.; Villanueva, L; Sinninghe Damste, J. S.

    2016-01-01

    RATIONALE: Intact polar lipids (IPLs) are the building blocks of cell membranes, and amino acid containing IPLs havebeen observed to be involved in response to changing environmental conditions in various species of bacteri a. High-performance liquid chromatography/mass spectrometry (HPLC/MS) has become the primary method for analysis ofIPLs. Many glycerol-free amino acid containing membrane lipids (AA-IPLs), which are structurally different thanabundant aminophospholipids, have not been char...

  9. Automated processing of whole blood samples for the determination of immunosuppressants by liquid chromatography tandem-mass spectrometry

    OpenAIRE

    Vogeser, Michael; Spöhrer, Ute

    2006-01-01

    Background: Liquid chromatography tandem-mass spectrometry (LC-MS/MS) is an efficient technology for routine determination of immunosuppressants in whole blood; however, time-consuming manual sample preparation remains a significant limitation of this technique. Methods: Using a commercially available robotic pipetting system (Tecan Freedom EVO), we developed an automated sample-preparation protocol for quantification of tacrolimus in whole blood by LC-MS/MS. Barcode reading, sample resuspens...

  10. Systemic Metabolomic Changes in Blood Samples of Lung Cancer Patients Identified by Gas Chromatography Time-of-Flight Mass Spectrometry

    OpenAIRE

    Suzanne Miyamoto; Taylor, Sandra L.; Barupal, Dinesh K; Ayumu Taguchi; Gert Wohlgemuth; Wikoff, William R.; Yoneda, Ken Y.; Gandara, David R.; Samir M. Hanash; Kyoungmi Kim; Oliver Fiehn

    2015-01-01

    Lung cancer is a leading cause of cancer deaths worldwide. Metabolic alterations in tumor cells coupled with systemic indicators of the host response to tumor development have the potential to yield blood profiles with clinical utility for diagnosis and monitoring of treatment. We report results from two separate studies using gas chromatography time-of-flight mass spectrometry (GC-TOF MS) to profile metabolites in human blood samples that significantly differ from non-small cell lung cancer ...

  11. High performance liquid chromatography-tandem mass spectrometry of pharmaceuticals and personal care products in environmental and biological matrices

    OpenAIRE

    Purcell, Martha

    2009-01-01

    Pharmaceuticals and personal care products (PPCPs) have emerged in recent years as a new class of chemical and biological pollutants in our environment. In the search for suitably sensitive and specific techniques for detection of these compounds at very low concentrations, liquid chromatography-tandem mass spectrometry (LCMS/ MS) has emerged as the new technique of choice. This work describes methods for screening and quantification of various pharmaceutical and illicit drug residues i...

  12. Simultaneous determination of 14 β-lactam antibiotics in cosmetic products by liquid chromatography tandem mass spectrometry method

    Institute of Scientific and Technical Information of China (English)

    Cai Sheng Wu; Jin Lan Zhang; Yan Ling Qiao; Yi Lin Wang; Zhi Rong Chen

    2011-01-01

    In this study, a simple and rapid high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was established and validated to determine the 14 β-lactam antibiotics in cosmetic products, including 1 (ceftazidime), 2 (cefaclor), 3 (cefdinir), 4 (ampicillin), 5 (cefalexin), 6 (ceftezole), 7 (cefotaxim), 8 (cefradine), 9 (cefuroxime), 10 (cephazoline), 11 (cefathiamidine), 12 (cefoperazone), 13 (cafalotin), 14 (piperacillin).

  13. Assessing Gibberellins Oxidase Activity by Anion Exchange/Hydrophobic Polymer Monolithic Capillary Liquid Chromatography-Mass Spectrometry

    OpenAIRE

    Ming-Luan Chen; Xin Su; Wei Xiong; Jiu-Feng Liu; Yan Wu; Yu-Qi Feng; Bi-Feng Yuan

    2013-01-01

    Bioactive gibberellins (GAs) play a key regulatory role in plant growth and development. In the biosynthesis of GAs, GA3-oxidase catalyzes the final step to produce bioactive GAs. Thus, the evaluation of GA3-oxidase activity is critical for elucidating the regulation mechanism of plant growth controlled by GAs. However, assessing catalytic activity of endogenous GA3-oxidase remains challenging. In the current study, we developed a capillary liquid chromatographymass spectrometry (cLC-MS) m...

  14. Signal and Charge Enhancement for Protein Analysis by Liquid Chromatography-Mass Spectrometry with Desorption Electrospray Ionization

    OpenAIRE

    Liu, Yan; Miao, Zhixin; Lakshmanan, Rajeswari; Ogorzalek Loo, Rachel R.; Loo, Joseph A.; Chen, Hao

    2012-01-01

    We recently reported the use of desorption electrospray ionization (DESI) as a novel interface to couple high-performance liquid chromatography (HPLC) with mass spectrometry (MS) (Chem. Commun. 2011, 47, 4171). One of the benefits of such an interface is that post-column derivatization of separated analytes can be integrated with ionization via a “reactive” DESI approach in which a derivatizing reagent is doped into the spray solvent. The reactive DESI interface allows analyte desorption/ioni...

  15. Development of a Gas Chromatography-Mass Spectrometry Method for the Quantification of Glucaric Acid Derivatives in Beverage Substrates

    OpenAIRE

    Ana Paula Craig; Fields, Christine C.; Simpson, John V.

    2014-01-01

    A gas chromatography-mass spectrometry (GC-MS) method using the standard addition methodology was developed for the determination of glucuronolactone (GL) and glucuronic acid (DGuA) in four beverages categorized as detoxification, recovery, or energy drinks. The method features a precolumn derivatization step with a combination of BSTFA (N,O-bis(trimethylsilyl)trifluoroacetamide) and TMCS (trimethylchlorosilane) to silylate the analytes. The sample pretreatment required no extraction, filtrat...

  16. The Global Volatile Signature of Veal via Solid-phase Microextraction and Gas Chromatography-mass Spectrometry

    OpenAIRE

    Wei, Jinmei; Wan, Kun; Luo, Yuzhu; Zhang, Li

    2014-01-01

    The volatile composition of veal has yet to be reported and is one of the important factors determining meat character and quality. To identify the most important aroma compounds in veal from Holstein bull calves fed one of three diets, samples were subjected to solid-phase microextraction (SPME) combined with gas chromatography-quadrupole mass spectrometry (GC-MS). Most of the important odorants were aldehydes and alcohols. For group A (veal calves fed entirely on milk for 90 d before slaugh...

  17. Analysis of Androgenic Steroids in Environmental Waters by Large-volume Injection Liquid Chromatography Tandem Mass Spectrometry

    OpenAIRE

    Backe, Will J.; Ort, Christoph; Brewer, Alex J.; Field, Jennifer A.

    2011-01-01

    A new method was developed for the analysis of natural and synthetic androgenic steroids and their selected metabolites in aquatic environmental matrices using direct large-volume injection (LVI) high performance liquid chromatography (HPLC) tandem mass spectrometry (MS/MS). Method accuracy ranged from 88 to 108% for analytes with well-matched internal standards. Precision, quantified by relative standard deviation (RSD), was less than 12%. Detection limits for the method ranged from 1.2 to 3...

  18. Determining the amount of Acrylamide in Potato Chips Using Xanthydrol as a Derivative Representative with Gas Chromatography-Mass Spectrometry

    OpenAIRE

    Maryam Zokaei; Marzieh Kamankesh; Saeideh Shojaei; Abdorreza Mohammadi

    2016-01-01

    Background and Objectives: In the production process of foods rich in carbohydrates and some other foods containing precursors of acrylamide formation, there is the possibility of acrylamide creation, which is a mutagen and carcinogen material. This study aims to introduce and optimize a new method for determining acrylamide in potato chips using xanthydrol as a derivative representative with gas chromatography-mass spectrometry. Materials and Methods: Important factors in the derivatizat...

  19. Identification and hazard prediction of tattoo pigments by means of pyrolysis—gas chromatography/mass spectrometry

    OpenAIRE

    Schreiver, Ines; Hutzler, Christoph; Andree, Sarah; Laux, Peter; Luch, Andreas

    2016-01-01

    The implementation of regulation for tattoo ink ingredients across Europe has generated the need for analytical methods suitable to identify prohibited compounds. Common challenges of this subject are the poor solubility and the lack of volatility for most pigments and polymers applied in tattoo inks. Here, we present pyrolysis coupled to online gas chromatography and electron impact ionization mass spectrometry (py-GC/MS) as quick and reliable tool for pigment identification using both purif...

  20. Paclobutrazol Residue Determination in Potato and Soil Using Low Temperature Partition Extraction and Ultrahigh Performance Liquid Chromatography Tandem Mass Spectrometry

    OpenAIRE

    Hongcheng Liu; Tao Lin; Jia Mao; Huan Lu; Dongshun Yang; Jiliang Wang; Qiwan Li

    2015-01-01

    A simple, accurate, and highly sensitive analytical method was developed for determining the paclobutrazol residue in potato and soil, the dynamics dissipation in soil. Extraction was carried out by low temperature partitioning and analyzed by ultrahigh performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). For a favor extraction yield, the parameters such as temperature and solvent were optimized. The result showed that sample would be easily frozen and separated using ace...

  1. Metabolite profiling of Triterpene Saponins in medicago truncatula hairy roots by liquid chromatography fourier transform Ion Cyclotron resonance mass spectrometry

    OpenAIRE

    Pollier, Jacob; Morreel, Kris; Geelen, Danny; Goossens, Alain

    2011-01-01

    Triterpenes are one of the largest classes of plant natural products, with an enormous variety in structure and bioactivities. Here, triterpene saponins from hairy roots of the model legume Medicago truncatula were profiled with reversed-phase liquid chromatography coupled to negative-ion electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (LC ESI FT-ICR MS). Owing to the accuracy of the FT-ICR MS, reliable molecular formulas of the detected compounds could be ...

  2. Quantitative selenium speciation in human urine by using liquid chromatography-electrospray tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lu Ying [University of Crete, Department of Chemistry, Environmental Chemical Processes Laboratory, Voutes Campus, Heraklion 71003, Crete (Greece); Rumpler, Alice; Francesconi, Kevin A. [Institute of Chemistry-Analytical Chemistry, Karl-Franzens University Graz, Graz (Austria); Pergantis, Spiros A., E-mail: spergantis@chemistry.uoc.gr [University of Crete, Department of Chemistry, Environmental Chemical Processes Laboratory, Voutes Campus, Heraklion 71003, Crete (Greece)

    2012-06-20

    Highlights: Black-Right-Pointing-Pointer Development of a selected reaction monitoring mass spectrometric method for the identification of Se species in human urine. Black-Right-Pointing-Pointer A selenosugar was detected as the major human urinary metabolite of selenium in the samples analysed. Black-Right-Pointing-Pointer The trimethylselenonium ion was detected in the urine of one volunteer before and after receiving a selenium supplement. Black-Right-Pointing-Pointer Strict quality control measures were applied to validate identification. Black-Right-Pointing-Pointer Quantitation was conducted using an isotopically labelled internal standard and the standard additions methodology. - Abstract: A liquid chromatography-electrospray-tandem mass spectrometry (ES-MS/MS) method was developed for the speciation analysis of four organic selenium species of relevance to human urinary metabolism, namely trimethylselenomium ion (TMSe{sup +}), selenomethionine (SeMet) and the two selenosugars, methyl 2-acetamido-2-deoxy-1-seleno-{beta}-D-galactos/-glucos-amine (SeGalNAc and SeGluNAc, respectively). Their chromatographic separation was achieved by using a cation exchange pre-column coupled in-series with a reversed-phase high-performance liquid chromatography column, along with an isocratic mobile phase. Online detection was performed using ES-MS/MS in selective reaction monitoring mode. SeGalNAc was detected as the major human urinary metabolite of selenium in the samples analysed, whereas TMSe{sup +} was detected in the urine of one volunteer before and after receiving a selenium supplement. SeMet was not detected as a urine excretory metabolite in this study. Spiking experiments performed with the urine samples revealed significant signal suppression caused by coeluting matrix constituents. To overcome such interferences, isotopically labelled {sup 13}CD{sub 3}{sup 82}SeGalNAc was used as an internal standard, whereas in the absence of an isotopically labelled internal

  3. Analysis of four pentacyclic triterpenoid acids in several bioactive botanicals with gas and liquid chromatography and mass spectrometry detection.

    Science.gov (United States)

    Moldoveanu, Serban C; Scott, Wayne A

    2016-01-01

    Several pentacyclic triterpenoid acids including betulinic, oleanolic, and ursolic acids were reported to have health beneficial properties such as antiviral and anti-inflammatory properties, as well as the capability to inhibit "in vitro" the development of various cancer cell types. For this reason betulinic, oleanolic, and ursolic acids are used as neutraceuticals. For the analysis of the pentacyclic triterpenoid acids in complex plant materials, an improved scheme was developed, involving a qualitative screening using silylation and gas chromatography with mass spectrometry analysis, followed by quantitation using a novel liquid chromatography with tandem mass spectrometry procedure. The use of the two methods provides more reliable information regarding the plant materials with unknown composition. Besides betulinic, oleanolic, and ursolic acids that were analyzed, by this procedure a fourth pentacyclic triterpenoid acid was identified and quantitated that was not previously reported to be present in plants. This acid has been identified as 3β-3-hydroxy-lupa-18,20(29)-dien-28-oic acid. The newly identified acid has a structure as a derivative of lupane, although lupane with a double bond in the 18-position was not previously reported as present in plants. The new liquid chromatography with tandem mass spectrometry procedure developed for this study offers a very low limit of quantitation, excellent precision, and robustness. Rosemary was found to contain the largest levels of pentacyclic triterpenoid acids among all the analyzed botanicals. PMID:26549610

  4. Comparative analysis of steroidal saponins in four Dioscoreae herbs by high performance liquid chromatography coupled with mass spectrometry.

    Science.gov (United States)

    Guo, Long; Zeng, Su-Ling; Zhang, Yu; Li, Ping; Liu, E-Hu

    2016-01-01

    Steroidal saponins, which exhibit multiple pharmacological effects, are the major bioactive constituents in herbal medicines from Dioscoreae species. In this study, a sensitive method based on high performance liquid chromatography-mass spectrometry (HPLC-MS) was established and validated for qualitative and quantitative analysis of steroidal saponins in four Dioscoreae herbs including Dioscoreae Nipponica Rhizome (DNR) and Dioscoreae Hypoglaucae Rhizome (DHR), Dioscoreae Spongiosae Rhizome (DSR) and Dioscoreae Rhizome (DR). A total of eleven steroidal saponins were identified by high performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (HPLC-QTOF/MS). Furthermore, seven major steroidal saponins was simultaneous quantified using a high performance liquid chromatography coupled with triple quadrupole mass spectrometry (HPLC-QQQ/MS). The qualitative and quantitative analysis results indicated that the chemical composition of DNR, DHR and DSR samples exhibited a high level of global similarity, while the ingredients in DR varied greatly from the other three herbs. Moreover, principal component analysis (PCA) and hierarchical clustering analysis (HCA) were performed to compare and discriminate the Dioscoreae herbs based on the quantitative data. The results demonstrated the qualitative and quantitative analysis of steroidal saponins based on HPLC-MS is a feasible method for quality control of Dioscoreae herbs.

  5. Detection of 10 sweeteners in various foods by liquid chromatography/tandem mass spectrometry

    OpenAIRE

    Chui-Shiang Chang; Tai Sheng Yeh

    2014-01-01

    The analytical method for sweeteners in various food matrixes is very important for food quality control and regulation enforcement. A simple and rapid method for the simultaneous determination of 10 sweeteners [acesulfame potassium (ACS-K), aspartame (ASP), cyclamate (CYC), dulcin (DUL), glycyrrhizic acid (GA), neotame (NEO), neohesperidin dihydrochalcone (NHDC), saccharin (SAC), sucralose (SCL), and stevioside (STV)] in various foods by liquid chromatography/tandem mass chromatography (LC–M...

  6. Enantioselective simultaneous analysis of selected pharmaceuticals in environmental samples by ultrahigh performance supercritical fluid based chromatography tandem mass spectrometry.

    Science.gov (United States)

    Camacho-Muñoz, Dolores; Kasprzyk-Hordern, Barbara; Thomas, Kevin V

    2016-08-31

    In order to assess the true impact of each single enantiomer of pharmacologically active compounds (PACs) in the environment, highly efficient, fast and sensitive analytical methods are needed. For the first time this paper focuses on the use of ultrahigh performance supercritical fluid based chromatography coupled to a triple quadrupole mass spectrometer to develop multi-residue enantioselective methods for chiral PACs in environmental matrices. This technique exploits the advantages of supercritical fluid chromatography, ultrahigh performance liquid chromatography and mass spectrometry. Two coated modified 2.5 μm-polysaccharide-based chiral stationary phases were investigated: an amylose tris-3,5-dimethylphenylcarbamate column and a cellulose tris-3-chloro-4-methylphenylcarbamate column. The effect of different chromatographic variables on chiral recognition is highlighted. This novel approach resulted in the baseline resolution of 13 enantiomers PACs (aminorex, carprofen, chloramphenicol, 3-N-dechloroethylifosfamide, flurbiprofen, 2-hydroxyibuprofen, ifosfamide, imazalil, naproxen, ofloxacin, omeprazole, praziquantel and tetramisole) and partial resolution of 2 enantiomers PACs (ibuprofen and indoprofen) under fast-gradient conditions (chromatography coupled with tandem mass spectrometry. PMID:27506366

  7. Analysis of ochratoxin A in pig tissues using high pressure liquid chromatography (HPLC) and liquid chromatography tandem mass spectrometry (LC/MS/MS) as confirmative methods

    OpenAIRE

    Milićević Dragan R.; Jurić Verica B.; Stefanović Srđan M.; Vesković-Moračanin Slavica M.; Janković Saša I.

    2009-01-01

    Two different analytical methods for the determination and confirmation of ochratoxin A (OTA) in blood serum, kidney and liver of pigs have been compared. Sample clean-up was based on liquid-liquid phase extraction. The detection of OTA was accomplished with high-performance liquid chromatography (HPLC) combined either with fluorescence detection (FL) or electro spray ionization (ESI+) tandem mass spectrometry (MS-MS). Comparative method evaluation was based on the investigation of 82 samples...

  8. Screening antiallergic components from Carthamus tinctorius using rat basophilic leukemia 2H3 cell membrane chromatography combined with high-performance liquid chromatography and tandem mass spectrometry.

    Science.gov (United States)

    Han, Shengli; Huang, Jing; Cui, Ronghua; Zhang, Tao

    2015-02-01

    Carthamus tinctorius, used in traditional Chinese medicine, has many pharmacological effects, such as anticoagulant effects, antioxidant effects, antiaging effects, regulation of gene expression, and antitumor effects. However, there is no report on the antiallergic effects of the components in C. tinctorius. In the present study, we investigated the antiallergic components of C. tinctorius and its mechanism of action. A rat basophilic leukemia 2H3/cell membrane chromatography coupled online with high-performance liquid chromatography and tandem mass spectrometry method was developed to screen antiallergic components from C. tinctorius. The screening results showed that Hydroxysafflor yellow A, from C. tinctorius, was the targeted component that retained on the rat basophilic leukemia 2H3/cell membrane chromatography column. We measured the amount of β-hexosaminidase and histamine released in mast cells and the key markers of degranulation. The release assays showed that Hydroxysafflor yellow A could attenuate the immunoglobulin E induced release of allergic cytokines without affecting cell viability from 1.0 to 50.0 μM. In conclusion, the established rat basophilic leukemia 2H3 cell membrane chromatography coupled with online high-performance liquid chromatography and tandem mass spectrometry method successfully screened and identified Hydroxysafflor yellow A from C. tinctorius as a potential antiallergic component. Pharmacological analysis elucidated that Hydroxysafflor yellow A is an effective natural component for inhibiting immunoglobulin E-antigen-mediated degranulation.

  9. Linker-assisted immunoassay and liquid chromatography/mass spectrometry for the analysis of glyphosate

    Science.gov (United States)

    Lee, E.A.; Zimmerman, L.R.; Bhullar, B.S.; Thurman, E.M.

    2002-01-01

    A novel, sensitive, linker-assisted enzyme-linked immunosorbent assay (L'ELISA) was compared to on-line solidphase extraction (SPE) with high-performance liquid chromatography/mass spectrometry (HPLC/MS) for the analysis of glyphosate in surface water and groundwater samples. The L'ELISA used succinic anhydride to derivatize glyphosate, which mimics the epitotic attachment of glyphosate to horseradish peroxidase hapten. Thus, L'ELISA recognized the derivatized glyphosate more effectively (detection limit of 0.1 ??g/L) and with increased sensitivity (10-100 times) over conventional ELISA and showed the potential for other applications. The precision and accuracy of L'ELISA then was compared with on-line SPE/HPLC/MS, which detected glyphosate and its degradate derivatized with 9-fluorenylmethyl chloroformate using negative-ion electrospray (detection limit 0.1 ??g/L, relative standard deviation ??15%). Derivatization efficiency and matrix effects were minimized by adding an isotope-labeled glyphosate (2-13C15N). The accuracy of L'ELISA gave a false positive rate of 18% between 0.1 and 1.0 ??g/L and a false positive rate of only 1% above 1.0 ??g/L. The relative standard deviation was ??20%. The correlation of L'ELISA and HPLC/MS for 66 surface water and groundwater samples was 0.97 with a slope of 1.28, with many detections of glyphosate and its degradate in surface water but not in groundwater.

  10. Linker-assisted immunoassay and liquid chromatography/mass spectrometry for the analysis of glyphosate.

    Science.gov (United States)

    Lee, E A; Zimmerman, L R; Bhullar, B S; Thurman, E M

    2002-10-01

    A novel, sensitive, linker-assisted enzyme-linked immunosorbent assay (L'ELISA) was compared to on-line solid-phase extraction (SPE) with high-performance liquid chromatography/mass spectrometry (HPLC/MS) for the analysis of glyphosate in surface water and groundwater samples. The L'ELISA used succinic anhydride to derivatize glyphosate, which mimics the epitotic attachment of glyphosate to horseradish peroxidase hapten. Thus, L'ELISA recognized the derivatized glyphosate more effectively (detection limit of 0.1 microg/L) and with increased sensitivity (10-100 times) over conventional ELISA and showed the potential for other applications. The precision and accuracy of L'ELISA then was compared with on-line SPE/HPLC/MS, which detected glyphosate and its degradate derivatized with 9-fluorenylmethyl chloroformate using negative-ion electrospray (detection limit 0.1 microg/ L, relative standard deviation +/- 15%). Derivatization efficiency and matrix effects were minimized by adding an isotope-labeled glyphosate (2-13C15N). The accuracy of L'EUSA gave a false positive rate of 18% between 0.1 and 1.0 microg/L and a false positive rate of only 1% above 1.0 microg/L The relative standard deviation was +/- 20%. The correlation of L'ELISA and HPLC/MS for 66 surface water and groundwater samples was 0.97 with a slope of 1.28, with many detections of glyphosate and its degradate in surface water but not in groundwater.

  11. Determination of tetracycline residues in soil by pressurized liquid extraction and liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Andreu, Vicente; Vazquez-Roig, Pablo; Blasco, Cristina; Picó, Yolanda

    2009-07-01

    An optimized extraction and cleanup method for the analysis of chlortetracycline (CTC), doxycycline (DC), oxytetracycline (OTC) and tetracycline (TC) in soil is presented. Soil extraction in a pressurized liquid extraction system, followed by extract clean up using solid-phase extraction (SPE) and tetracycline determination by liquid chromatography tandem mass spectrometry (LC-MS/MS) provided appropriate efficiency and reproducibility. Different dispersing agents and solvents for soil extraction and several SPE cartridges for cleanup were compared. The best extraction results were obtained using ethylenediamine tetraacetic acid-treated sand as dispersing agent, and water at 70 degrees C. The most effective cleanup was obtained using Strata-X sorbent in combination with a strong anion exchange cartridge. Recoveries ranged from 71% to 96% and precision, as indicated by the relative standard deviations, was within the range of 8-15%. The limits of quantification (LOQs) by using LC-MS/MS, based on signal-to-noise ratio (S/N) of 10, ranged from 1 microg kg(-1) for TC to 5 microg kg(-1) for CTC. These results pointed out that this technique is appropriate to determine tetracyclines in soils. Analysis of 100 samples taken in the Valencian Community revealed that, in soil, up to 5 microg kg(-1) CTC, 15 microg kg(-1) OTC, 18 microg kg(-1) TC, and 12 microg kg(-1) DC could be detected. Detection of the analytes in several samples, which typify great part of the Spanish agricultural soils, should be outlined as most important result of this study. PMID:19205670

  12. Determination of pharmaceuticals in biosolids using accelerated solvent extraction and liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Ding, Yunjie; Zhang, Weihao; Gu, Cheng; Xagoraraki, Irene; Li, Hui

    2011-01-01

    An analytical method was developed to quantitatively determine pharmaceuticals in biosolid (treated sewage sludge) from wastewater treatment plants (WWTPs). The collected biosolid samples were initially freeze dried, and grounded to obtain relatively homogenized powders. Pharmaceuticals were extracted using accelerated solvent extraction (ASE) under the optimized conditions. The optimal operation parameters, including extraction solvent, temperature, pressure, extraction time and cycles, were identified to be acetonitrile/water mixture (v/v 7:3) as extraction solvent with 3 extraction cycles (15 min for each cycle) at 100 °C and 100 bars. The extracts were cleaned up using solid-phase extraction followed by determination by liquid chromatography coupled with tandem mass spectrometry. For the 15 target pharmaceuticals commonly found in the environment, the overall method recoveries ranged from 49% to 68% for tetracyclines, 64% to 95% for sulfonamides, and 77% to 88% for other pharmaceuticals (i.e. acetaminophen, caffeine, carbamazepine, erythromycin, lincomycin and tylosin). The developed method was successfully validated and applied to the biosolid samples collected from WWTPs located in six cities in Michigan. Among the 15 target pharmaceuticals, 14 pharmaceuticals were detected in the collected biosolid samples. The average concentrations ranged from 2.6 μg/kg for lincomycin to 743.6 μg/kg for oxytetracycline. These results indicated that pharmaceuticals could survive wastewater treatment processes, and accumulate in sewage sludge and biosolids. Subsequent land application of the contaminated biosolids could lead to the dissemination of pharmaceuticals in soil and water environment, which poses potential threats to at-risk populations in the receiving ecosystems. PMID:21112593

  13. On-line high speed lipid extraction for nanoflow liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lee, Ju Yong; Yang, Joon Seon; Park, Se Mi; Byeon, Seul Kee; Moon, Myeong Hee

    2016-09-16

    An on-line lipid extraction method is introduced by utilizing a short capillary extraction column using HILIC and C4 particles prior to nanoflow liquid chromatography-tandem mass spectrometry (nLC-MS/MS). The on-line extraction using a urine sample spiked with PL standards showed similar or slightly higher recovery values (86%-96%) of phospholipids (PLs) compared to those obtained by the conventional off-line extraction based on the Folch method with or without using the air-exposed drying process. In this study, we demonstrated that PL oxidation can occur during the air-exposed drying process of lipid extracts in standard liquid-liquid extraction procedures, which was confirmed by the oxidized PL (OxPL) molecules that were generated from an off-line extraction using a few PL standards. Quantitative comparison of these OxPL species between on- and off-line extraction followed by nLC-MS/MS with multiple reaction monitoring (MRM) analysis showed a significant decrease (2-10 fold) in unwanted OxPL species when on-line extraction was employed. While the number of identified PLs from a urine sample was somewhat lower than those by off-line extraction, the number of OxPLs was significantly reduced (from 70 to 22) with on-line extraction. The new method offers high speed (∼5min) automated extraction of PLs with nLC-MS/MS analysis and presents the possibility of handling a biological sample with a very limited amount of lipids. PMID:27530420

  14. Detection of 36 antibiotics in coastal waters using high performance liquid chromatography-tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    NA Guangshui; GU Jia; GE Linke; ZHANG Peng; WANG Zhen; LIU Chunyang; ZHANG Lin

    2011-01-01

    Among pharmaceuticals and personal care products released into the aquatic environment,antibiotics are of particular concern,because of their ubiquity and health effects.Although scientists have recently paid more attention to the threat of antibiotics to coastal ecosystems,researchers have often focused on relatively few antibiotics,because of the absence of suitable analytical methods.We have therefore developed a method for the rapid detection of 36 antibiotic residues in coastal waters,including tetracyclines (TCs),sulfanilamides (SAs),and quinolones (QLs).The method consists of solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis,using electrospray ionization (ESI) in positive mode.The SPE was performed with Oasis HLB and Oasis MCX cartridges.Chromatographic separation on a C18 column was achieved using a binary eluent containing methanol and water with 0.1% formic acid.Typical recoveries of the analytes ranged from 67.4% to 109.3% at a fortification level of 100 ng/L.The precision of the method,calculated as relative standard deviation (RSD),was below 14.6% for all the compounds.The limits of detection (LODs) varied from 0.45 pg to 7.97 pg.The method was applied to determine the target analytes in coastal waters of the Yellow Sea in Liaoning,China.Among the tested antibiotics,31 were found in coastal waters,with their concentrations between the LOD and 212.5 ng/L.These data indicate that this method is valid for analysis of antibiotics in coastal waters.The study first reports such a large number of antibiotics along the Yellow Sea coast of Liaoning,and should facilitate future comprehensive evaluation of antibiotics in coastal ecosystems.

  15. Detection of stanozolol in environmental waters using liquid chromatography tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Petroczi Andrea

    2011-10-01

    Full Text Available Abstract Background Owing to frequent administration of a wide range of pharmaceutical products, various environmental waters have been found to be contaminated with pharmacologically active substances. For example, stanozolol, a synthetic anabolic steroid, is frequently misused for performance enhancement as well as for illegal growth promoting purposes in veterinary practice. Previously we reported stanozolol in hair samples collected from subjects living in Budapest. For this reason we initiated this study to explore possible environmental sources of steroid contamination. The aim of this study was to develop a method to monitor stanozolol in aqueous matrices using liquid chromatography tandem mass spectrometry (LC-MS/MS. Results Liquid-liquid extraction using pentane was found to be an efficient method for the extraction of stanozolol from water samples. This was followed by direct detection using LC-MS/MS. The method was capable of detecting 0.25 pg/mL stanozolol when only 5 mL water was processed in the presence of stanozolol D3 as internal standard. Fifteen bottled waters analysed were found to be negative for stanozolol. However, three out of six samples from the Danube river, collected from December '09 to November '10, were found to contain stanozolol at concentrations up to 1.82 pg/mL. In contrast, only one sample (out of six of urban tap water from Budapest city was found to contain stanozolol, at a concentration of 1.19 pg/mL. Conclusion The method developed is efficient, rapid, reproducible, sensitive and robust for the detection of stanozolol in aqueous matrices.

  16. Urine Mescaline Screening With a Biochip Array Immunoassay and Quantification by Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Battal, Dilek; Barnes, Allan J; Castaneto, Marisol S; Martin, Thomas M; Klette, Kevin L; Huestis, Marilyn A

    2015-12-01

    Mescaline, the primary psychoactive chemical in peyote cactus, has been consumed for thousands of years in ancient religious ceremonies. The US military wanted to determine if mescaline intake was a problem for personnel readiness. Twenty thousand seventeen urine specimens negative for cannabinoids, cocaine, opiates, and amphetamines were tested for mescaline with the Randox Drugs of Abuse V (DOA-V) biochip array immunoassay at the manufacturer's recommended cutoff of 6 mcg/L. A sensitive and specific method for mescaline quantification in urine was developed and fully validated. Extracted analytes were derivatized with pentafluoropropionic anhydride and pentafluoropropanol and quantified by gas chromatography-mass spectrometry (GC/MS) with electron impact ionization. Standard curves, using linear least squares regression with 1/x weighting, were linear from 1 to 250 mcg/L with coefficients of determination >0.994. Intra- and inter-assay imprecision was 90.4%. Mean extraction efficiencies were >92.0% across the linear range. This fully validated method was applied for the confirmation of urinary mescaline in 526 presumptive-positive specimens and 198 randomly selected presumptive-negative specimens at the manufacturer's 6 mcg/L cutoff. No specimen confirmed positive at the GC/MS limit of quantification of 1 mcg/L. Results indicated that during this time frame, there was insufficient mescaline drug use in the military to warrant routine screening in the drug testing program. However, mescaline stability, although assessed, could have contributed to lower prevalence. We also present a validated GC/MS method for mescaline quantification in urine for reliable confirmation of suspected mescaline intake.

  17. Metabolomic Analysis of Gingival Crevicular Fluid Using Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Ozeki, Miho; Nozaki, Takenori; Aoki, Jun; Bamba, Takeshi; Jensen, Kirk R.; Murakami, Shinya; Toyoda, Michisato

    2016-01-01

    Periodontitis is one of the most prevalent threats to oral health as the most common cause of tooth loss. In order to perform effective treatment, a clinical test that detect sites where disease activity is high and predicts periodontal tissue destruction is strongly desired, however, it is still difficult to prognose the periodontal tissue breakdown on the basis of conventional methods. The aim of this study is to examine the usefulness of gas chromatography/mass spectrometry (GC/MS), which could eventually be used for on-site analysis of metabolites in gingival crevicular fluid (GCF) in order to objectively diagnose periodontitis at a molecular level. GCF samples were collected from two diseased sites (one site with a moderate pocket and another site with a deep pocket) from each patient and from clinically healthy sites of volunteers. Nineteen metabolites were identified using GC/MS. Total ion current chromatograms showed broad differences in metabolite peak patterns between GCF samples obtained from healthy sites, moderate-pocket sites, and deep-pocket sites. The intensity difference of some metabolites was significant at sites with deep pockets compared to healthy sites. Additionally, metabolite intensities at moderate-pocket sites showed an intermediate profile between the severely diseased sites and healthy sites, which suggested that periodontitis progression could be observed with a changing metabolite profile. Principal component analysis confirmed these observations by clearly delineating healthy sites and sites with deep pockets. These results suggest that metabolomic analysis of GCF could be useful for prediction and diagnosis of periodontal disease in a single visit from a patient and provides the groundwork for establishing a new, on-site diagnostic method for periodontitis. PMID:27446770

  18. Validation of keratan sulfate level in mucopolysaccharidosis type IVA by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tomatsu, Shunji; Montaño, Adriana M; Oguma, Toshihiro; Dung, Vu Chi; Oikawa, Hirotaka; de Carvalho, Talita Giacomet; Gutiérrez, María L; Yamaguchi, Seiji; Suzuki, Yasuyuki; Fukushi, Masaru; Kida, Kazuhiro; Kubota, Mitsuru; Barrera, Luis; Orii, Tadao

    2010-12-01

    Mucopolysaccharidosis type IVA (MPS IVA, Morquio A disease), a progressive lysosomal storage disease, causes skeletal chondrodysplasia through excessive storage of keratan sulfate (KS). KS is synthesized mainly in cartilage and released to the circulation. The excess storage of KS disrupts cartilage, consequently releasing more KS into circulation, which is a critical biomarker for MPS IVA. Thus, assessment of KS level provides a potential screening strategy and determines clinical course and efficacy of therapies. We have recently developed a tandem mass spectrometry liquid chromatography [LC/MS/MS] method to assay KS levels in blood. Forty-nine blood specimens from patients with MPS IVA [severe (n = 33), attenuated (n = 11) and undefined (n = 5)] were analyzed for comparison of blood KS concentration with that of healthy subjects and for correlation with clinical severity. Plasma samples were digested by keratanase II to obtain disaccharides of KS. Digested samples were assayed by LC/MS/MS. We found that blood KS levels (0.4-26 µg/ml) in MPS IVA patients were significantly higher than those in age-matched controls (0.67-4.6 µg/ml; P IVA peaked between 2 years and 5 years of age (mean 11.4 µg/ml). Blood KS levels in severe MPS IVA (mean 7.3 µg/ml) were higher than in the attenuated form (mean 2.1 µg/ml) (P = 0.012). We also found elevated blood KS levels in other types of MPS. These findings indicate that the new KS assay for blood is suitable for early diagnosis and longitudinal assessment of disease severity in MPS IVA.

  19. Analysis of 23 polycyclic aromatic hydrocarbons in smokeless tobacco by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Stepanov, Irina; Villalta, Peter W; Knezevich, Aleksandar; Jensen, Joni; Hatsukami, Dorothy; Hecht, Stephen S

    2010-01-01

    Smokeless tobacco contains 28 known carcinogens and causes precancerous oral lesions and oral and pancreatic cancer. A recent study conducted by our research team identified eight different polycyclic aromatic hydrocarbons (PAHs) in U.S. moist snuff, encouraging further investigations of this group of toxicants and carcinogens in smokeless tobacco products. In this study, we developed a gas chromatography-mass spectrometry method that allows simultaneous analysis of 23 various PAHs in smokeless tobacco after a simple two-step extraction and purification procedure. The method produced coefficients of variation under 10% for most PAHs. The limits of quantitation for different PAHs varied between 0.3 and 11 ng/g tobacco, starting with a 300 mg sample. The recovery of the stable isotope-labeled internal standards averaged 87%. The method was applied to analysis of 23 moist snuff samples that included various flavors of the most popular U.S. moist snuff brands, as well as 17 samples representing the currently marketed brands of spit-free tobacco pouches, a relatively new type of smokeless tobacco. The sum of all detected PAHs in conventional moist snuff averaged 11.6 (+/-3.7) microg/g dry weight; 20% of this amount was comprised of carcinogenic PAHs. The levels of PAHs in new spit-free tobacco products were much lower than those in moist snuff; the sum of all detected PAHs averaged 1.3 (+/-0.28) microg/g dry weight. Our findings render PAHs one of the most prevalent groups of carcinogens in smokeless tobacco. Urgent measures are required from the U.S. tobacco industry to modify manufacturing processes so that the levels of these toxicants and carcinogens in U.S. moist snuff are greatly reduced.

  20. Determination of anabolic agents in dietary supplements by liquid chromatography-high-resolution mass spectrometry.

    Science.gov (United States)

    Odoardi, Sara; Castrignanò, Erika; Martello, Simona; Chiarotti, Marcello; Strano-Rossi, Sabina

    2015-01-01

    A sensitive method for the identification and quantification of anabolic steroids and clenbuterol at trace levels in dietary supplements by liquid chromatography-high-resolution mass spectrometry (LC-HRMS) in atmospheric pressure ionisation (APCI) mode using a single-stage Orbitrap analyser operating at a resolution power of 100 000 full width at half maximum (FWHM) was developed and validated. A total of 1 g of dietary supplement was added with testosterone-d3 as internal standard, dissolved in methanol, evaporated to dryness, diluted in sodium hydroxide solution and extracted with a mixture of pentane/ethyl ether 9:1. The extract was directly injected into the LC-HRMS system. The method was fully validated. Limits of detection (LODs) obtained for anabolic androgenic steroids (AASs) varied from 1 to 25 ng g(-1) and the limit of quantitation (LOQ) was 50 ng g(-1) for all analytes. The calibration was linear for all compounds in the range from the LOQ to 2000 ng g(-1), with correlation coefficients always higher than 0.99. Accuracy (intended as %E) and repeatability (%CV) were always lower than 15%. Good values of matrix effect and recovery were achieved. The ease of the sample preparation together with a fast run time of only 16 min permitted rapid identification of the analytes. The method was applied to the analysis of 30 dietary supplements in order to check for the presence of anabolic agents not labelled as being present in these supplements. Many AASs were often detected in the same sample: indeed, androstenedione was detected in nine supplements, 5-androsten-3β-ol-17-one (DHEA) in 12, methandienone in three, stanozolol in one, testosterone in seven and testosterone esters in four of them. A retrospective analysis of suspected compounds not included at the beginning of the method development was also possible by means of the full acquisition spectra obtained with the HRMS technique.

  1. Metabolomic Analysis of Gingival Crevicular Fluid Using Gas Chromatography/Mass Spectrometry.

    Science.gov (United States)

    Ozeki, Miho; Nozaki, Takenori; Aoki, Jun; Bamba, Takeshi; Jensen, Kirk R; Murakami, Shinya; Toyoda, Michisato

    2016-01-01

    Periodontitis is one of the most prevalent threats to oral health as the most common cause of tooth loss. In order to perform effective treatment, a clinical test that detect sites where disease activity is high and predicts periodontal tissue destruction is strongly desired, however, it is still difficult to prognose the periodontal tissue breakdown on the basis of conventional methods. The aim of this study is to examine the usefulness of gas chromatography/mass spectrometry (GC/MS), which could eventually be used for on-site analysis of metabolites in gingival crevicular fluid (GCF) in order to objectively diagnose periodontitis at a molecular level. GCF samples were collected from two diseased sites (one site with a moderate pocket and another site with a deep pocket) from each patient and from clinically healthy sites of volunteers. Nineteen metabolites were identified using GC/MS. Total ion current chromatograms showed broad differences in metabolite peak patterns between GCF samples obtained from healthy sites, moderate-pocket sites, and deep-pocket sites. The intensity difference of some metabolites was significant at sites with deep pockets compared to healthy sites. Additionally, metabolite intensities at moderate-pocket sites showed an intermediate profile between the severely diseased sites and healthy sites, which suggested that periodontitis progression could be observed with a changing metabolite profile. Principal component analysis confirmed these observations by clearly delineating healthy sites and sites with deep pockets. These results suggest that metabolomic analysis of GCF could be useful for prediction and diagnosis of periodontal disease in a single visit from a patient and provides the groundwork for establishing a new, on-site diagnostic method for periodontitis. PMID:27446770

  2. Gas chromatography/mass spectrometry based component profiling and quality prediction for Japanese sake.

    Science.gov (United States)

    Mimura, Natsuki; Isogai, Atsuko; Iwashita, Kazuhiro; Bamba, Takeshi; Fukusaki, Eiichiro

    2014-10-01

    Sake is a Japanese traditional alcoholic beverage, which is produced by simultaneous saccharification and alcohol fermentation of polished and steamed rice by Aspergillus oryzae and Saccharomyces cerevisiae. About 300 compounds have been identified in sake, and the contribution of individual components to the sake flavor has been examined at the same time. However, only a few compounds could explain the characteristics alone and most of the attributes still remain unclear. The purpose of this study was to examine the relationship between the component profile and the attributes of sake. Gas chromatography coupled with mass spectrometry (GC/MS)-based non-targeted analysis was employed to obtain the low molecular weight component profile of Japanese sake including both nonvolatile and volatile compounds. Sake attributes and overall quality were assessed by analytical descriptive sensory test and the prediction model of the sensory score from the component profile was constructed by means of orthogonal projections to latent structures (OPLS) regression analysis. Our results showed that 12 sake attributes [ginjo-ka (aroma of premium ginjo sake), grassy/aldehydic odor, sweet aroma/caramel/burnt odor, sulfury odor, sour taste, umami, bitter taste, body, amakara (dryness), aftertaste, pungent/smoothness and appearance] and overall quality were accurately explained by component profiles. In addition, we were able to select statistically significant components according to variable importance on projection (VIP). Our methodology clarified the correlation between sake attribute and 200 low molecular components and presented the importance of each component thus, providing new insights to the flavor study of sake. PMID:25060729

  3. Role of cathode identity in liquid chromatography particle beam glow discharge mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Krishna, M.V. Balarama [Department of Chemistry, Biosystems Research Complex, Clemson University, Clemson, SC 29634-1905 (United States); Marcus, R.K. [Department of Chemistry, Biosystems Research Complex, Clemson University, Clemson, SC 29634-1905 (United States)], E-mail: marcusr@clemson.edu

    2008-06-15

    A detailed evaluation of the role of cathode identity on the analytical and spectral characteristics of various organic, organometallic and metal analytes using liquid chromatography-particle beam/glow discharge mass spectrometry (LC-PB/GDMS) has been carried out. A d.c. discharge, operating with argon as the support gas, was used throughout this work. In this study, Cu which has a relatively high sputtering rate, Ni which has moderate sputtering rate and Ta which has very low sputtering rate, are taken as cathode materials to study the ionization, fragmentation, and analytical characteristics of organic (caffeine, epigallocatechin gallate, peptide as representative compounds), organometallic (selenomethionine, triethyl lead chloride as representative compounds) and metal (Fe, La, Cs and Pb) species. A range of discharge gas pressures (26.6-106.4 Pa) and currents (0.2-1.5 mA) were investigated with the test cathodes to determine their influence on the spectral composition and overall analytical response for the various test species. Calibration plots were obtained for all of the species for each of the three cathodes to determine the respective limits of detection. Relative detection limits in the range of 0.02 to 15 ng mL{sup -1} (0.002-1.5 ng, absolute) for the test species were found to be in the order of Cu > Ni > Ta; which follows the order of the sputtering characteristics of the respective cathodes. These studies rendered information about the respective discharge parameters' role in choosing the most appropriate cathode identity in PB-GDMS for application in the areas of organic, organometallic and inorganic species analysis.

  4. Simultaneous quantification of multiple urinary naphthalene metabolites by liquid chromatography tandem mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Daniel C Ayala

    Full Text Available Naphthalene is an environmental toxicant to which humans are exposed. Naphthalene causes dose-dependent cytotoxicity to murine airway epithelial cells but a link between exposure and human pulmonary disease has not been established. Naphthalene toxicity in rodents depends on P450 metabolism. Subsequent biotransformation results in urinary elimination of several conjugated metabolites. Glucuronide and sulfate conjugates of naphthols have been used as markers of naphthalene exposure but, as the current studies demonstrate, these assays provide a limited view of the range of metabolites generated from the parent hydrocarbon. Here, we present a liquid chromatography tandem mass spectrometry method for measurement of the glucuronide and sulfate conjugates of 1-naphthol as well as the mercapturic acids and N-acetyl glutathione conjugates from naphthalene epoxide. Standard curves were linear over 2 log orders. On column detection limits varied from 0.91 to 3.4 ng; limits of quantitation from 1.8 to 6.4 ng. The accuracy of measurement of spiked urine standards was -13.1 to + 5.2% of target and intra-day and inter-day variability averaged 7.2 (± 4.5 and 6.8 (± 5.0 %, respectively. Application of the method to urine collected from mice exposed to naphthalene at 15 ppm (4 hrs showed that glutathione-derived metabolites accounted for 60-70% of the total measured metabolites and sulfate and glucuronide conjugates were eliminated in equal amounts. The method is robust and directly measures several major naphthalene metabolites including those derived from glutathione conjugation of naphthalene epoxide. The assays do not require enzymatic deconjugation, extraction or derivatization thus simplifying sample work up.

  5. Triple sorbent thermal desorption/gas chromatography/mass spectrometry determination of vapor phase organic contaminants

    International Nuclear Information System (INIS)

    A thermal desorption/ps chromatography/mass spectrometry (TD/GC/MS) has been evaluated for the determination of volatile organic compounds (VOCS) in vapor phase samples using Carbosieve S-III/Carbotrap/Carotrap C triple sorbent traps (TST) similar to those available from a commercial source. The analysis was carried out with a Hewlett-Packard 5985A or 5995 GC/MS system with a modified injector to adapt an inhouse manufactured short-path desorber for transferring desorbate directly onto a cryofocusing loop for subsequent GC/MS analysis. Vapor phase standards generated from twenty six compounds were used for method validation, including alkanes, alkyl alcohols, alkyl ketones, and alkyl nitrites, a group of representative compounds that have previously been identified in a target airborne matrix. The method was validated based on the satisfactory results in terms of reproducibility, recovery rate, stability, and linearity. A relative, standard deviation of 0.55 to 24.3 % was obtained for the entire TD process (generation of gas phase standards, spiking the standards on and desorbing from TST) over a concentration range of 20 to 500 ng/trap. Linear correlation coefficients for the calibration curves as determined ranged from 0.81 to 0.99 and limits of detection ranged from 3 to 76 ng. For a majority of standards, recoveries of greater than 90% were observed. For three selected standards spiked on TSTS, minimal loss (10 to 22%) was observed after storing the spiked in, a 4 degree C refrigerator for 29 days. The only chromatographable artifact observed was a 5% conversion of isopropanol to acetone. The validated method been successfully applied, to the determination of VOCs collected from various emission sources in a diversified concentration range

  6. Serum metabolic profiling of human gastric cancer based on gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Research on molecular mechanisms of carcinogenesis plays an important role in diagnosing and treating gastric cancer. Metabolic profiling may offer the opportunity to understand the molecular mechanism of carcinogenesis and help to non-invasively identify the potential biomarkers for the early diagnosis of human gastric cancer. The aims of this study were to explore the underlying metabolic mechanisms of gastric cancer and to identify biomarkers associated with morbidity. Gas chromatography/mass spectrometry (GC/MS) was used to analyze the serum metabolites of 30 Chinese gastric cancer patients and 30 healthy controls. Diagnostic models for gastric cancer were constructed using orthogonal partial least squares discriminant analysis (OPLS-DA). Acquired metabolomic data were analyzed by the nonparametric Wilcoxon test to find serum metabolic biomarkers for gastric cancer. The OPLS-DA model showed adequate discrimination between cancer and non-cancer cohorts while the model failed to discriminate different pathological stages (I-IV) of gastric cancer patients. A total of 44 endogenous metabolites such as amino acids, organic acids, carbohydrates, fatty acids, and steroids were detected, of which 18 differential metabolites were identified with significant differences. A total of 13 variables were obtained for their greatest contribution in the discriminating OPLS-DA model [variable importance in the projection (VIP) value >1.0], among which 11 metabolites were identified using both VIP values (VIP >1) and the Wilcoxon test. These metabolites potentially revealed perturbations of glycolysis and of amino acid, fatty acid, cholesterol, and nucleotide metabolism of gastric cancer patients. These results suggest that gastric cancer serum metabolic profiling has great potential in detecting this disease and helping to understand its metabolic mechanisms

  7. Quantitation of Insulin Analogues in Serum Using Immunoaffinity Extraction, Liquid Chromatography, and Tandem Mass Spectrometry.

    Science.gov (United States)

    Van Der Gugten, J Grace; Wong, Sophia; Holmes, Daniel T

    2016-01-01

    Insulin analysis is used in combination with glucose, C-peptide, beta-hydroxybutyrate, and proinsulin determination for the investigation of adult hypoglycemia. The most common cause is the administration of too much insulin or insulin secretagogue to a diabetic patient or inadequate caloric intake after administration of either. Occasionally there is a question as to whether hypoglycemia has been caused by an exogenous insulin-whether by accident, intent, or even malicious intent. While traditionally this was confirmed by a low or undetectable C-peptide in a hypoglycemic specimen, this finding is not entirely specific and would also be expected in the context of impaired counter-regulatory response, fatty acid oxidation defects, and liver failure-though beta-hydroxybutyrate levels can lend diagnostic clarity. For this reason, insulin is often requested. However, popular automated chemiluminescent immunoassays for insulin have distinctly heterogeneous performance in detecting analogue synthetic insulins with cross-reactivities ranging from near 0 % to greater than 100 %. The ability to detect synthetic insulins is vendor-specific and varies between insulin products. Liquid Chromatography and Tandem Mass Spectrometry (LC-MS/MS) offers a means to circumvent these analytical issues and both quantify synthetic insulins and identify the specific type. We present an immunoaffinity extraction and LC-MS/MS method capable of independent identification and quantitation of native sequence insulins (endogenous, Insulin Regular, Insulin NPH), and analogues Glargine, Lispro, Detemir, and Aspart with an analytical sensitivity for endogenous insulin of between 1 and 2 μU/mL in patient serum samples.

  8. Cyclic pentapeptide analogs based on endomorphin-2 structure: cyclization studies using liquid chromatography combined with on-line mass spectrometry and tandem mass spectrometry.

    Science.gov (United States)

    Piekielna, Justyna; Kluczyk, Alicja; Perlikowska, Renata; Janecka, Anna

    2014-05-01

    The cyclization of linear analogs based on endomorphin-2 structure, Tyr/Dmt-d-Lys-Phe-Phe-Asp-NH2 and Tyr/Dmt-d-Cys-Phe-Phe-Cys-NH2 (where Dmt=2',6'-dimethyltyrosine), resulting in obtaining lactam or disulfide derivatives, was studied using liquid chromatography combined with on-line mass spectrometry (LC-MS) and tandem mass spectrometry (LC-MS/MS). In case of cyclization via an amide bond, the formation of the cyclic monomers, cyclic but not linear dimers and even traces of cyclic trimers was observed. Disulfide bridge containing peptides was obtained by the solid-phase synthesis of the linear sequences, followed by either in-solution or on-resin cyclization. In case of the in-solution cyclization, the expected cyclic monomers were the only products. When oxidation of the cysteine residues was performed when the peptides were still on the resin, cyclic monomer and two cyclodimers, parallel and antiparallel, were found. Digestion of the isolated cyclodimers with α-chymotrypsin allowed for their unambiguous identification. The comparison of the cyclic monomer/dimer ratios for analogs with Tyr versus Dmt in position 1 revealed that the presence of the exocyclic Dmt favored formation of the cyclic monomer, most likely due to the increased steric bulk of this amino acid side-chain as compared with Tyr. PMID:24525024

  9. Cyclic pentapeptide analogs based on endomorphin-2 structure: cyclization studies using liquid chromatography combined with on-line mass spectrometry and tandem mass spectrometry.

    Science.gov (United States)

    Piekielna, Justyna; Kluczyk, Alicja; Perlikowska, Renata; Janecka, Anna

    2014-05-01

    The cyclization of linear analogs based on endomorphin-2 structure, Tyr/Dmt-d-Lys-Phe-Phe-Asp-NH2 and Tyr/Dmt-d-Cys-Phe-Phe-Cys-NH2 (where Dmt=2',6'-dimethyltyrosine), resulting in obtaining lactam or disulfide derivatives, was studied using liquid chromatography combined with on-line mass spectrometry (LC-MS) and tandem mass spectrometry (LC-MS/MS). In case of cyclization via an amide bond, the formation of the cyclic monomers, cyclic but not linear dimers and even traces of cyclic trimers was observed. Disulfide bridge containing peptides was obtained by the solid-phase synthesis of the linear sequences, followed by either in-solution or on-resin cyclization. In case of the in-solution cyclization, the expected cyclic monomers were the only products. When oxidation of the cysteine residues was performed when the peptides were still on the resin, cyclic monomer and two cyclodimers, parallel and antiparallel, were found. Digestion of the isolated cyclodimers with α-chymotrypsin allowed for their unambiguous identification. The comparison of the cyclic monomer/dimer ratios for analogs with Tyr versus Dmt in position 1 revealed that the presence of the exocyclic Dmt favored formation of the cyclic monomer, most likely due to the increased steric bulk of this amino acid side-chain as compared with Tyr.

  10. EPA Method 525.3 - Determination of Semivolatile Organic Chemicals in Drinking Water by Solid Phase Extraction and Capillary Column Gas Chromatography/Mass Spectrometry (GC/MS)

    Science.gov (United States)

    Method 525.3 is an analytical method that uses solid phase extraction (SPE) and gas chromatography/mass spectrometry (GC/MS) for the identification and quantitation of 125 selected semi-volatile organic chemicals in drinking water.

  11. MEASUREMENT OF PYRETHROID RESIDUES IN ENVIRONMENTAL AND FOOD SAMPLES BY ENHANCED SOLVENT EXTRACTION/SUPERCRITICAL FLUID EXTRACTION COUPLED WITH GAS CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY

    Science.gov (United States)

    The abstract summarizes pyrethorid methods development research. It provides a summary of sample preparation and analytical techniques such as supercritical fluid extraction, enhance solvent extraction, gas chromatography and tandem mass spectrometry.

  12. METHOD 332.0: DETERMINATION OF PERCHLORATE IN DRINKING WATER BY ION CHROMATOGRAPHY WITH SUPPRESSED CONDUCTIVITY AND ELECTROSPRAY IONIZATION MASS SPECTROMETRY

    Science.gov (United States)

    This method is applicable to the identification and quantitation of perchlorate in raw and finished drinking waters. The approach used is ion chromatography with suppressed conductivity and electrospray ionization mass spectrometry (IC-ESI/MS)

  13. Optimization of a liquid chromatography-tandem mass spectrometry method for quantification of the plant lignans secoisolariciresinol, matairesinol, lariciresinol and pinoresinol in foods

    NARCIS (Netherlands)

    Milder, I.E.J.; Arts, I.C.W.; Venema, D.P.; Lasaroms, J.J.P.; Wähälä, K.; Hollman, P.C.H.

    2004-01-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the quantification of the four major enterolignan precursors [secoisolariciresinol, matairesinol, lariciresinol, and pinoresinol] in foods. The method consists of alkaline methanolic extraction, followed by enzymati

  14. Characterization of phenolic amides from cortex lycii by ultra high-performance liquid chromatography coupled with LTQ-Orbitrap mass spectrometry

    Science.gov (United States)

    High performance liquid chromatography (UPLC) and flow injection electrospray ionization with ion trap mass spectrometry (FIMS) fingerprints combined with the principal component analysis (PCA) were examined for their potential in differentiating commercial organic and conventional sage samples. The...

  15. Gas Chromatography and Mass Spectrometry Measurements and Protocols for Database and Library Development Relating to Organic Species in Support of the Mars Science Laboratory

    Science.gov (United States)

    Misra, P.; Garcia, R.; Mahaffy, P. R.

    2010-04-01

    An organic contaminant database and library has been developed for use with the Sample Analysis at Mars (SAM) instrumentation utilizing laboratory-based Gas Chromatography-Mass Spectrometry measurements of pyrolyzed and baked material samples.

  16. Comparative oxidation state specific analysis of arsenic species by high-performance liquid chromatography- inductively coupled plasma-mass spectrometry and hydride generation-cryotrapping-atomic absorption spectrometry

    OpenAIRE

    Currier, J. M.; Saunders, R J; Ding, L.; Bodnar, W.; Cable, P.; Matoušek, T. (Tomáš); Creed, J. T.; Stýblo, M.

    2013-01-01

    The formation of methylarsonous acid (MAsIII) and dimethylarsinous acid (DMAsIII) in the course of inorganic arsenic (iAs) metabolism plays an important role in the adverse effects of chronic exposure to iAs. High-performance liquid chromatography-inductively coupled plasma-mass spectrometry (HPLC-ICP-MS) and hydride generation-cryotrapping-atomic absorption spectrometry (HG-CT-AAS) have been frequently used for the analysis of MAsIII and DMAsIII in biological samples. While HG-CT-AAS has con...

  17. Stable Isotope Labeling Strategy for Curcumin Metabolite Study in Human Liver Microsomes by Liquid Chromatography-Tandem Mass Spectrometry

    Science.gov (United States)

    Gao, Dan; Chen, Xiaowu; Yang, Xiaomei; Wu, Qin; Jin, Feng; Wen, Hongliang; Jiang, Yuyang; Liu, Hongxia

    2015-04-01

    The identification of drug metabolites is very important in drug development. Nowadays, the most widely used methods are isotopes and mass spectrometry. However, the commercial isotopic labeled reagents are usually very expensive, and the rapid and convenient identification of metabolites is still difficult. In this paper, an 18O isotope labeling strategy was developed and the isotopes were used as a tool to identify drug metabolites using mass spectrometry. Curcumin was selected as a model drug to evaluate the established method, and the 18O labeled curcumin was successfully synthesized. The non-labeled and 18O labeled curcumin were simultaneously metabolized in human liver microsomes (HLMs) and analyzed by liquid chromatography/mass spectrometry (LC-MS). The two groups of chromatograms obtained from metabolic reaction mixture with and without cofactors were compared and analyzed using Metabolynx software (Waters Corp., Milford, MA, USA). The mass spectra of the newly appearing chromatographic peaks in the experimental sample were further analyzed to find the metabolite candidates. Their chemical structures were confirmed by tandem mass spectrometry. Three metabolites, including two reduction products and a glucuronide conjugate, were successfully detected under their specific HLMs metabolic conditions, which were in accordance with the literature reported results. The results demonstrated that the developed isotope labeling method, together with post-acquisition data processing using Metabolynx software, could be used for fast identification of new drug metabolites.

  18. Liquid chromatography "on-flow" 1H nuclear magnetic resonance on native glycosphingolipid mixtures together with gas chromatography/mass spectrometry on the released oligosaccharides for screening and characterisation of carbohydrate-based antigens from pig lungs.

    Science.gov (United States)

    Bäcker, A E; Thorbert, S; Rakotonirainy, O; Hallberg, E C; Olling, A; Gustavsson, M; Samuelsson, B E; Soussi, B

    1999-01-01

    Glycosphingolipids were prepared from pig lung and pooled into two fractions with (i) or = 3 sugar residues. Oligosaccharides were prepared and used for gas chromatography, gas chromatography/mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry. The glycolipid fractions i and ii were further characterised and purified using a novel method based on high performance liquid chromatography "on-flow" proton nuclear magnetic resonance. The LC "on-flow" NMR technique showed good chromatographic separation and gave NMR spectral information which could be used as guidance for pooling of the separated mixture glycolipids. Conventional 1H NMR, thin layer immunostaining, gas chromatography, gas chromatography/mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry were used to characterise the glycolipids and to validate LC-NMR spectral data.

  19. Determination of olanzapine in whole blood using simple protein precipitation and liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Marie Katrine Klose; Johansen, Sys Stybe

    2009-01-01

    A simple, sensitive, and reproducible liquid chromatography-tandem mass spectrometry method has been developed and validated for the quantification of the antipsychotic drug olanzapine in whole blood using dibenzepine as internal standard (IS). After acidic methanol-induced protein precipitation...... of the whole blood samples, olanzapine and IS were chromatographed on a reversed-phase Zorbax Extend-C(18)-column at pH 9.0. Quantification was performed on a triple-quadrupole mass spectrometer employing electrospray ionization technique operating in multiple reaction monitoring and positive ion mode. Total...

  20. Multiresidue analysis of pesticides in straw roughage by liquid chromatography - tandem mass spectrometry

    Science.gov (United States)

    A multiresidue analytical method using a modification of the “quick, easy, cheap, effective, rugged, and safe” (QuEChERS) sample preparation approach combined with liquid chromatography–tandem mass spectrometry (LC-MS/MS) analysis was established and validated for the rapid determination of 69 pesti...

  1. Quantification of almond skin polyphenols by liquid chromatography-mass spectrometry

    Science.gov (United States)

    Reverse phase HPLC coupled to negative mode electrospray ionization (ESI) mass spectrometry (MS) was used to quantify 16 flavonoids and 2 phenolic compounds from almond skin extracts. Calibration curves of standard compounds were run daily and daidzein was used as an internal standard. The inter-da...

  2. Quantitative analysis of phytosterols in edible oils using APCI liquid chromatography-tandem mass spectrometry

    OpenAIRE

    Mo, Shunyan; Dong, Linlin; Hurst, W Jeffrey; van Breemen, Richard B

    2013-01-01

    Previous methods for the quantitative analysis of phytosterols have usually used GC-MS and require elaborate sample preparation including chemical derivatization. Other common methods such as HPLC with absorbance detection do not provide information regarding the identity of the analytes. To address the need for an assay that utilizes mass selectivity while avoiding derivatization, a quantitative method based on LC-tandem mass spectrometry (LC-MS-MS) was developed and validated for the measur...

  3. Gas chromatography mass spectrometry analysis and in vitro antibacterial activity of essential oil from Trigonella foenum-graecum

    Institute of Scientific and Technical Information of China (English)

    Moniruzzaman; Shahinuzzaman; Ahsanul Haque; Rahima Khatun; Zahira Yaakob

    2015-01-01

    Objective: To evaluate the antibacterial activity of essential oil from Trigonella foenum-graecum seeds powder, and identify the compounds from the extracted oil. Methods: The seeds powder of Trigonella foenum-graecum was subjected to Clevenger extractor. Seven strains of bacteria were used to test antibacterial activity of the extract. The activity against bacteria was tested by disk diffusion method using Whatman No. 1 filter paper. Gas chromatography mass spectrometry analysis was performed with an Agilent7890/5975B-gas chromatography/mass selective detector. Results: The hydrodistillation of seeds powder yielded 0.285%(v/w) of oil. Disk diffu-sion of the oil showed bactericidal activity against both Gram negative and Gram positive bacteria of tasted strains. The inhibition zone ranged from (8 ± 0) mm to (15.0 ± 0.7) mm depending on microbial strains. Gas chromatography mass spectrometry analysis showed 14 different compounds. The total compounds represented 80.96%of the oil. Conclusions: The antibacterial activity is due to the effects of different biological active compounds present in the extract. Identification of the compounds may help to develop new effective antimicrobial agent(s). Further researches on purification, characterization and toxicology of the active compounds are needed.

  4. Gas chromatography mass spectrometry analysis and in vitro antibacterial activity of essential oil from Trigonella foenum-graecum

    Institute of Scientific and Technical Information of China (English)

    Moniruzzaman; Shahinuzzaman; Ahsanul; Haque; Rahima; Khatun; Zahira; Yaakob

    2015-01-01

    Objective:To evaluate the antibacterial activity of essential oil from Trigonella foenumgraecum seeds powder,and identify the compounds from the extracted oil.Methods:The seeds powder of Trigonella foenum-graecum was subjected to Clevenger extractor.Seven strains of bacteria were used to test antibacterial activity of the extract.The activity against bacteria was tested by disk diffusion method using Whatman No.1filter paper.Gas chromatography mass spectrometry analysis was performed with an Agilent7890/5975B-gas chromatography/mass selective detector.Results:The hydrodistillation of seeds powder yielded 0.285%(v/w)of oil.Disk diffusion of the oil showed bactericidal activity against both Gram negative and Gram positive bacteria of tasted strains.The inhibition zone ranged from(8±0)mm to(15.0±0.7)mm depending on microbial strains.Gas chromatography mass spectrometry analysis showed14 different compounds.The total compounds represented 80.96%of the oil.Conclusions:The antibacterial activity is due to the effects of different biological active compounds present in the extract.Identification of the compounds may help to develop new effective antimicrobial agent(s).Further researches on purification,characterization and toxicology of the active compounds are needed.

  5. Exploration of cardanol-based phenolated and epoxidized resins by size exclusion chromatography and MALDI mass spectrometry.

    Science.gov (United States)

    Fouquet, Thierry; Puchot, Laura; Verge, Pierre; Bomfim, João A S; Ruch, David

    2014-09-16

    Cardanol and cardanol derivatives are among the most important biobased materials currently investigated in green chemistry, as renewable and promising building blocks in lieu of traditional raw materials from non renewable resources, in particular owing to the olefinic linkages on the C15 alkyl side-chain. Despite the increasing interest they arouse, analytical chemistry dedicated to cardanol and associated resins has been rarely reported in the literature, found even poorer when dealing with chromatography and mass spectrometry. In this work, a thorough molecular characterization was conducted using matrix assisted laser desorption ionization (MALDI) mass spectrometry, size exclusion chromatography (SEC), and SEC-MALDI coupling to gain insights into the composition of phenolated, epoxidized, and epoxidized phenolated cardanol. A nomenclature was proposed to properly describe the numerous species found in these materials, while simulations of the unsaturation patterns and their comparison with the detected patterns in MALDI-MS gave useful details about the phenolation treatment expected to occur on the polyunsaturated C15 side chain. Finally, the SEC-MALDI off-line coupling allowed SEC peaks to be deconvoluted by mass spectrometry and MALDI artefacts related to matrix adduction to be pointed out. PMID:25150696

  6. Potential of monitoring isotopologues by quantitative gas chromatography with time-of-flight mass spectrometry for metabolomic assay.

    Science.gov (United States)

    Wang, Yi; Hu, Haiyan; Su, Yue; Zhang, Fang; Guo, Yinlong

    2016-03-01

    Because of the extreme complexity of metabolomic samples, the effectiveness of quantitative gas chromatography with time-of-flight mass spectrometry depends substantially on the expansion of the linear dynamic range. Facing the existence of numerous saturated detector signals, a data processing method based on monitoring isotopologues has been developed. The monoisotopic ion kept the high mass spectrometry sensitivity, and the less abundant isotopologue ions extended the linear dynamic range. This alternative method was proved to extend the linear dynamic range to five orders of magnitude successfully and overcome the quantitative problems induced by the ion detector saturation. Finally, to validate the applicability, the method was applied to a metabolomic assay of Alzheimer's disease. Comparing with the traditional monoisotopic method, the use of monitoring isotopologues helped us to discover an additional eight metabolites with significant difference and to conduct a more reliable principal component analysis as well. The results demonstrated that monitoring isotopologues in quantitative gas chromatography with time-of-flight mass spectrometry could improve the authenticity of metabolomic analysis. PMID:26763370

  7. [Simultaneous determination of 16 flavonoids in the ginkgo dietary supplement tea by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Jiang, Yalan; Huang, Fang; Wu, Fuhai; Wu, Huiqin; Huang, Xiaolan; Deng, Xin

    2015-10-01

    A method for the determination of 16 functional components of ginkgo dietary supplement tea such as catechin, vitexin, puerarin, isoflavoues aglycone, silymarin, quercetin, luteolin, apigenin, naringenin, hesperitin dihydrochalcone, kaempferol, hesperitin, isorhamnetin, baicalein, nobiletin and tangeretin by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was proposed. The conditions of chromatography and mass spectrometry were optimized. The 16 flavonoids were separated on a C18 chromatographic column with acetonitrile and water (additional 0.1% formic acid) as mobile phases under gradient elution at a flow rate of 0.25 mL/min. The determination was conducted by tandem mass spectrometry in positive ESI mode under multiple reaction monitoring (MRM) mode. Good linearities for all the compounds, with correlation coefficients over 0.996, were acquired. The recoveries were in the range of 70.9% to 100.0% (n = 6), while the relative standard deviations (RSDs) were less than 10%. The results showed that the nine flavonoids, which were kaempferol, quercetin, hesperitin, vitexin, luteolin, catechin, apigenin, naringenin and isorhamnetin, were higher in contents among the 16 flavonoids in real samples, and they constituted up to 99.6% of the total flavonoids. The contents of these nine flavonoids can be considered as the quality control index of the ginkgo dietary supplement tea. The method proved to be rapid, selective, sensitive and stable, and it can be applied to control the quality of the ginkgo dietary supplement tea. PMID:26930959

  8. Report on three aliphatic dimethylarsinoyl compounds as common minor constituents in marine samples. An investigation using high-performance liquid chromatography inductively coupled plasma mass spectrometry and electrospray ionisation tandem mass spectrometry

    DEFF Research Database (Denmark)

    Sloth, Jens Jørgen; Larsen, Erik Huusfeldt; Julshamn, K.

    2005-01-01

    Three water-soluble aliphatic arsenicals, dimethylarsinoyl acetate (DMAA), dimethylarsinoyl ethanol (DMAE), and dimethylarsinoyl propionate (DMAP), were identified in marine biological samples. Sample extracts in methanol/water (1 + 1) were analysed by cation-exchange high-performance liquid...... chromatography/inductively coupled plasma mass spectrometry (HPLC/ICPMS). Eluate fractions from the HPLC/ICPMS analyses containing the compounds in question were collected and subjected to analysis by electrospray ionisation tandem mass spectrometry (ESI-MS/MS), which provided supportive evidence...

  9. [Determination of congo red in beef by high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry].

    Science.gov (United States)

    Lin, Hui; Xu, Chunxiang; Yan, Chunrong; Zhang, Zheng; Wang, Suilou

    2013-09-01

    A method was developed for the determination of congo red in beef. The analyte was identified by high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry (LC-QTOF MS) and quantitatively determined by ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry. After purified by liquid-liquid extraction, the congo red in the beef sample was separated on an Agilent ZORBAX Eclipse Plus C18 Rapid Resolution HD UPLC column (50 mm x 2.1 mm, 1.8 microm) HPLC , using 95% (volume percentage) methanol as the mobile phase at 0.2 mL/min. The detection was performed on an AB 4000 + triple quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operated in negative ion mode and multiple-reaction monitoring (MRM) mode. The results showed that the linear range of congo red mass concentration was 0.03 - 1 mg/L with the correlation coefficient of 0.999 8. The method had a good precision with the RSDs lower than 5% and the recoveries ranging from 88% to 91%. The limit of detection (LOD) of congo red was 0.01 mg/L. With good reproducibility, the method is simple, fast and effective for the determination of the illegally added congo red in beef and other meat products.

  10. Advancement and application of gas chromatography isotope ratio mass spectrometry techniques for atmospheric trace gas analysis

    Science.gov (United States)

    Giebel, Brian M.

    2011-12-01

    The use of gas chromatography isotope ratio mass spectrometry (GC-IRMS) for compound specific stable isotope analysis is an underutilized technique because of the complexity of the instrumentation and high analytical costs. However stable isotopic data, when coupled with concentration measurements, can provide additional information on a compounds production, transformation, loss, and cycling within the biosphere and atmosphere. A GC-IRMS system was developed to accurately and precisely measure delta13C values for numerous oxygenated volatile organic compounds having natural and anthropogenic sources. The OVOCs include methanol, ethanol, acetone, methyl ethyl ketone, 2-pentanone, and 3-pentanone. Guided by the requirements for analysis of trace components in air, the GC-IRMS system was developed with the goals of increasing sensitivity, reducing dead-volume and peak band broadening, optimizing combustion and water removal, and decreasing the split ratio to the IRMS. The technique relied on a two-stage preconcentration system, a low-volume capillary reactor and water trap, and a balanced reference gas delivery system. Measurements were performed on samples collected from two distinct sources (i.e. biogenic and vehicle emissions) and ambient air collected from downtown Miami and Everglades National Park. However, the instrumentation and the method have the capability to analyze a variety of source and ambient samples. The measured isotopic signatures that were obtained from source and ambient samples provide a new isotopic constraint for atmospheric chemists and can serve as a new way to evaluate their models and budgets for many OVOCs. In almost all cases, OVOCs emitted from fuel combustion were enriched in 13C when compared to the natural emissions of plants. This was particularly true for ethanol gas emitted in vehicle exhaust, which was observed to have a uniquely enriched isotopic signature that was attributed to ethanol's corn origin and use as an alternative

  11. Quantification of Neurotransmitters in Mouse Brain Tissue by Using Liquid Chromatography Coupled Electrospray Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Tae-Hyun Kim

    2014-01-01

    Full Text Available A simple and rapid liquid chromatography tandem mass spectrometry method has been developed for the determination of BH4, DA, 5-HT, NE, EP, Glu, and GABA in mouse brain using epsilon-acetamidocaproic acid and isotopically labeled neurotransmitters as internal standards. Proteins in the samples were precipitated by adding acetonitrile, and then the supernatants were separated by a Sepax Polar-Imidazole (2.1 mm × 100 mm, i.d., 3 μm column by adding a mixture of 10 mM ammonium formate in acetonitrile/water (75 : 25, v/v, 300 μl/min for BH4 and DA. To assay 5-HT, NE, EP, Glu, and GABA; a Luna 3 μ C18 (3.0 mm × 150 mm, i.d., 3 μm column was used by adding a mixture of 1% formic acid in acetonitrile/water (20 : 80, v/v, 350 μl/min. The total chromatographic run time was 5.5 min. The method was validated for the analysis of samples. The calibration curve was linear between 10 and 2000 ng/g for BH4 r2=0.995, 10 and 5000 ng/g for DA r2=0.997, 20 and 10000 ng/g for 5-HT r2=0.994, NE r2=0.993, and EP r2=0.993, and 0.2 and 200 μg/g for Glu r2=0.996 and GABA r2=0.999 in the mouse brain tissues. As stated above, LC-MS/MS results were obtained and established to be a useful tool for the quantitative analysis of BH4, DA, 5-HT, NE, EP, Glu, and GABA in the experimental rodent brain.

  12. A Rough Guide to Metabolite Identification Using High Resolution Liquid Chromatography Mass Spectrometry in Metabolomic Profiling in Metazoans

    Directory of Open Access Journals (Sweden)

    David G Watson

    2013-01-01

    Full Text Available Compound identification in mass spectrometry based metabolomics can be a problem but sometimes the problem seems to be presented in an over complicated way. The current review focuses on metazoans where the range of metabolites is more restricted than for example in plants. The focus is on liquid chromatography with high resolution mass spectrometry where it is proposed that most of the problems in compound identification relate to structural isomers rather than to isobaric compounds. Thus many of the problems faced relate to separation of isomers, which is usually required even if fragmentation is used to support structural identification. Many papers report the use of MS/MS or MS2 as an adjunct to the identification of known metabolites but there a few examples in metabolomics studies of metazoans of complete structure elucidation of novel metabolites or metabolites where no authentic standards are available for comparison.

  13. Identification of phosphorylation sites of proteins by high performance liquid chromatography-electrospray ionization-quadrupole ion trap mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    车发云; 邵晓霞; 夏其昌

    2000-01-01

    The phosphorylation sites of two phosphorylated proteins, bovine β-casein and myelin basic protein (MBP), were identified by high performance liquid chromatography-electrospray ionization-quadrupole ion trap mass spectrometry (HPLC-ESI-QITMS). The tryptic digest of each protein was separated by HPLC, the molecular weight of each peptide was determined by ESI-QITMS on line, and MS/MS spectrum of each peptide was simultaneously obtained by the combination of collision-induced desorption (CID) technique and tandem mass spectrometry (MS/MS) of QITMS. The phosphorylated peptide was identified by looking into whether the difference between the observed and predicted molecular weights of a peptide is 80 u or its integral multiple. Then the phosphorylation site was identified through manual interpretation of the MS/MS spectrum of the phosphorylated peptide or automatic SEQUEST data base-searching.

  14. Identification of phosphorylation sites of proteins by high performance liquid chromatography-electrospray ionization-quadrupole ion trap mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The phosphorylation sites of two phosphorylated proteins, bovine b-casein and myelin basic protein (MBP), were identified by high performance liquid chromatography-electrospray ionization-quadrupole ion trap mass spectrometry (HPLC-ESI-QITMS). The tryptic digest of each protein was separated by HPLC, the molecular weight of each peptide was determined by ESI-QITMS on line, and MS/MS spectrum of each peptide was simultaneously obtained by the combination of collision-induced desorption (CID) technique and tandem mass spectrometry (MS/MS) of QITMS. The phosphorylated peptide was identified by looking into whether the difference between the observed and predicted molecular weights of a peptide is 80 u or its integral multiple. Then the phosphorylation site was identified through manual interpretation of the MS/MS spectrum of the phosphorylated peptide or automatic SEQUEST data base-searching.

  15. ANALYSIS OF CHEMICAL COMPOUNDS OF AGARWOOD OIL FROM DIFFERENT SPECIES BY GAS CHROMATOGRAPHY MASS SPECTROMETRY (GCMS

    Directory of Open Access Journals (Sweden)

    Yumi Zuhanis Has-Yun Hashim

    2014-05-01

    Full Text Available ABSTRACT: Agarwood oil is a highly prized type of oil due to its unique aroma. The oil is extracted from the fragrant resin found in the agarwood tree (trunk.  The unique aroma and quality of agarwood resin and oil are contributed by the presence of certain chemical compounds. In this work, analysis and comparison of the chemical compounds of agarwood oil from A. malaccensis, A. sub-integra and a mixture of both were conducted.  The essential oils were diluted in hexane (5% prior to gas chromatography mass spectrometry (GCMS analysis performed using Agilent GCMS 7890A coupled with MSD quadrupole detector 5975 C.  Separation of analytes by gas chromatography was carried out using a Hewlett Packard HP-5MS silica capillary column (30 m X 0.25 mm X 0.25 mm. A total of 107 compounds were identified from the three samples of agarwood oils. Fifty-five (55 components were identified in A. malaccensis sample which contributes to the largest portion of the total compounds. About 20% of the compounds identified were aromatic and sesquiterpenes which have been revealed to be the main active compounds of agarwood oils which also give the aroma and pleasant odour of agarwood. Different compositions or profile of chemical components were found in agarwood oils from the two different species. Two compounds were commonly identified in all three samples namely 3-phenyl-2-butanone and alpha-cubebene.  Further studies are needed to refine the results which later can be used to assist detection and authentication of agarwood as well as its scientific-based grading. ABSTRAK: Minyak gaharu merupakan sejenis minyak beraroma unik yang mendapat permintaan tinggi dan mahal. Minyak ini diekstrak daripada resin beraroma yang terbentuk di dalam batang pokok gaharu. Keunikan aroma dan kualiti resin dan minyak gaharu ini bergantung kepada kehadiran bahan kimia tertentu. Penyelidikan ini menjurus kepada analisis dan perbandingan bahan-bahan kimia yang terdapat dalam minyak

  16. Speciation of Selenium in Selenium-Enriched Sunflower Oil by High-Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry/Electrospray-Orbitrap Tandem Mass Spectrometry.

    Science.gov (United States)

    Bierla, Katarzyna; Flis-Borsuk, Anna; Suchocki, Piotr; Szpunar, Joanna; Lobinski, Ryszard

    2016-06-22

    The reaction of sunflower oil with selenite produces a complex mixture of selenitriglycerides with antioxidant and anticancer properties. To obtain insight into the identity and characteristics of the species formed, an analytical approach based on the combination of high-performance liquid chromatography (HPLC) with (78)Se-specific selenium detection by inductively coupled plasma mass spectrometry (ICP MS) and high-resolution (100 000), high mass accuracy (sunflower oil dissolved in isopropanol and methanol extract of the oil containing 65% selenium. HPLC-ICP MS showed 14 peaks, 11 of which could also be detected in the methanol extract. Isotopic patterns corresponding to molecules with one or two selenium atoms could be attributed by Orbitrap MS at the retention times corresponding to the HPLC-ICP MS peak apexes. Structural data for these species were acquired by MS(2) and MS(3) fragmentation of protonated or sodiated ions using high-energy collisional dissociation (HCD). A total of 11 selenium-containing triglycerol derivatives resulting from the oxidation of one or two double bonds of linoleic acid and analogous derivatives of glycerol-mixed linoleate(s)/oleinate(s) have been identified for the first time. The presence of these species was confirmed by the targeted analysis in the total oil isopropanol solution. Their identification corroborated the predicted elution order in reversed-phase chromatography: LLL (glycerol trilinoleate), LLO (glycerol dilinoleate-oleinate), LOO (glycerol linoleate-dioleinate), OOO (glycerol trioleinate), of which the extrapolation allowed for the prediction of the identity [glycerol dioleinate-stearate (OOS) and glycerol oleinate-distearate (OSS)] of the nonpolar species detected by ICP MS in the oil but not detected by electrospray MS.

  17. Speciation of Selenium in Selenium-Enriched Sunflower Oil by High-Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry/Electrospray-Orbitrap Tandem Mass Spectrometry.

    Science.gov (United States)

    Bierla, Katarzyna; Flis-Borsuk, Anna; Suchocki, Piotr; Szpunar, Joanna; Lobinski, Ryszard

    2016-06-22

    The reaction of sunflower oil with selenite produces a complex mixture of selenitriglycerides with antioxidant and anticancer properties. To obtain insight into the identity and characteristics of the species formed, an analytical approach based on the combination of high-performance liquid chromatography (HPLC) with (78)Se-specific selenium detection by inductively coupled plasma mass spectrometry (ICP MS) and high-resolution (100 000), high mass accuracy (oil dissolved in isopropanol and methanol extract of the oil containing 65% selenium. HPLC-ICP MS showed 14 peaks, 11 of which could also be detected in the methanol extract. Isotopic patterns corresponding to molecules with one or two selenium atoms could be attributed by Orbitrap MS at the retention times corresponding to the HPLC-ICP MS peak apexes. Structural data for these species were acquired by MS(2) and MS(3) fragmentation of protonated or sodiated ions using high-energy collisional dissociation (HCD). A total of 11 selenium-containing triglycerol derivatives resulting from the oxidation of one or two double bonds of linoleic acid and analogous derivatives of glycerol-mixed linoleate(s)/oleinate(s) have been identified for the first time. The presence of these species was confirmed by the targeted analysis in the total oil isopropanol solution. Their identification corroborated the predicted elution order in reversed-phase chromatography: LLL (glycerol trilinoleate), LLO (glycerol dilinoleate-oleinate), LOO (glycerol linoleate-dioleinate), OOO (glycerol trioleinate), of which the extrapolation allowed for the prediction of the identity [glycerol dioleinate-stearate (OOS) and glycerol oleinate-distearate (OSS)] of the nonpolar species detected by ICP MS in the oil but not detected by electrospray MS. PMID:27214173

  18. Wide-scope screening and quantification of 50 pesticides in wine by liquid chromatography/quadrupole time-of-flight mass spectrometry combined with liquid chromatography/quadrupole linear ion trap mass spectrometry.

    Science.gov (United States)

    He, Zeying; Xu, Yaping; Wang, Lu; Peng, Yi; Luo, Ming; Cheng, Haiyan; Liu, Xiaowei

    2016-04-01

    In this paper, a wide scope screening method of pesticides in wine was established using liquid chromatography/quadrupole time-of-flight mass spectrometry (LC-QTOF MS) and liquid chromatography/quadrupole linear ion trap mass spectrometry (LC-QqLIT MS). Information dependent acquisition (IDA) experiments are used to obtain both MS and MS/MS information for LC-QTOF MS analysis. For LC-QqLIT MS analysis, MS/MS spectra of target pesticides were simultaneously acquired using Enhanced Product Ion (EPI) mode at very low concentrations to increase the confidence in analytical results of multiple reaction monitoring (MRM) by library searching. Method validation was carried out using 50 pesticides commonly used in vineyards. The LOQs, linearity, repeatability were determined and good enough for quantification. The screening and quantification results obtained using LC-QTOF MS and LC-QqLIT MS were compared. Contaminants were screened against libraries containing over 2800 compounds based on accurate mass, isotopic patterns, and MS/MS spectra searching to extend the scope of this methodology to non-target screening. PMID:26593613

  19. [Comparison of the performances of gas chromatography-quadrupole time of flight mass spectrometry and gas chromatography-tandem mass spectrometry in rapid screening and confirmation of 208 pesticide residues in fruits and vegetables].

    Science.gov (United States)

    Cao, Xinyue; Pang, Guofang; Jin, Linghe; Kang, Jian; Hu, Xueyan; Chang, Qiaoying; Wang, Minglin; Fan, Chunlin

    2015-04-01

    The performances of gas chromatography-tandem mass spectrometry (GC-MS/MS) and gas chromatography quadrupole time of flight mass spectrometry (GC-QTOF/MS) for the determination of 208 pesticide residues in fruit and vegetable samples, including apple, orange, tomato and cucumber, were compared comprehensively. Based on the differences of the two instruments, their respective characteristics and scopes of application in the detection of the pesticide residues were presented, which provided the reference for the analysis of pesticide residues. The performance parameters of the two instruments, such as overall recoveries, precisions, limits of detection, linear ranges, identification points and matrix effects, were evaluated according to a designed experiment. At three spiked levels (5.0, 10.0 and 20.0 µg/kg), the average recoveries for the majority of pesticides (93.0%) ranged from 70% to 120% in the four matrices with relative standard deviations below 20%. The limits of detection for most of the pesticides by GC-MS/MS and GC-Q-TOF/MS were less than 5.0 µg/kg. Compared with GC-QTOF/MS, GC-MS/MS showed relatively lower limits of detection and wider linear ranges, and its performance was more satisfactory in accurate quantitative analysis due to its superior sensitivity. On the other hand, GC-QTOF/MS provided accurate mass measurement, which was proved to be an efficient analytical tool on the rapid screening and confirmation of a large number of pesticides and non-target compounds.

  20. Wide-scope screening and quantification of 50 pesticides in wine by liquid chromatography/quadrupole time-of-flight mass spectrometry combined with liquid chromatography/quadrupole linear ion trap mass spectrometry.

    Science.gov (United States)

    He, Zeying; Xu, Yaping; Wang, Lu; Peng, Yi; Luo, Ming; Cheng, Haiyan; Liu, Xiaowei

    2016-04-01

    In this paper, a wide scope screening method of pesticides in wine was established using liquid chromatography/quadrupole time-of-flight mass spectrometry (LC-QTOF MS) and liquid chromatography/quadrupole linear ion trap mass spectrometry (LC-QqLIT MS). Information dependent acquisition (IDA) experiments are used to obtain both MS and MS/MS information for LC-QTOF MS analysis. For LC-QqLIT MS analysis, MS/MS spectra of target pesticides were simultaneously acquired using Enhanced Product Ion (EPI) mode at very low concentrations to increase the confidence in analytical results of multiple reaction monitoring (MRM) by library searching. Method validation was carried out using 50 pesticides commonly used in vineyards. The LOQs, linearity, repeatability were determined and good enough for quantification. The screening and quantification results obtained using LC-QTOF MS and LC-QqLIT MS were compared. Contaminants were screened against libraries containing over 2800 compounds based on accurate mass, isotopic patterns, and MS/MS spectra searching to extend the scope of this methodology to non-target screening.

  1. Characterization of phosphoantigens by high-performance anion-exchange chromatography-electrospray ionization ion trap mass spectrometry and nanoelectrospray ionization ion trap mass spectrometry.

    Science.gov (United States)

    Pont, F; Luciani, B; Belmant, C; Fournié, J J

    2001-08-01

    New phosphorylated microbial metabolites referred to as phosphoantigens activate immune responses in humans. Although these molecules have leading applications in medical research, no direct method allows their rapid and unambiguous structural identification. Here, we interfaced online HPAEC (high performance anion-exchange chromatography) with ESI-ITMS (electrospray ionization ion trap mass spectrometry) to identify such pyrophosphorylated molecules. A self-regenerating anion suppressor located upstream of electrospray ionization enabled the simultaneous detection of pyrophosphoester by conductimetry, UV and MS. By HPAEC-ITMS and HPAEC-ITMS2, a single run permitted characterization of reference phosphoantigens and of related structures. Although all compounds were resolved by HPAEC, MS enabled their detection and identification by [M-H]- and fragment ions. Isobaric phosphoantigen analogues were also separated by HPAEC and distinguished by MS2. The relevance of this device was demonstrated for phosphoantigens analysis in human urine and plasma. Furthermore, identification of natural phosphoantigens by automatically generated 2D mass spectra from nano-ESI-ITMS is presented. This last technique permits the simultaneous performance of molecular screening of natural phosphoantigen extracts and their identification.

  2. Multidimensional Separation of Natural Products Using Liquid Chromatography Coupled to Hadamard Transform Ion Mobility Mass Spectrometry

    Science.gov (United States)

    Liu, Wenjie; Zhang, Xing; Knochenmuss, Richard; Siems, William F.; Hill, Herbert H.

    2016-05-01

    A high performance liquid chromatograph (HPLC)was interfaced to an atmospheric drift tube ion mobility time of flight mass spectrometry. The power of multidimensional separation was demonstrated using chili pepper extracts. The ambient pressure drift tube ion mobility provided high resolving powers up to 166 for the HPLC eluent. With implementation of Hadamard transform (HT), the duty cycle for the ion mobility drift tube was increased from less than 1% to 50%, and the ion transmission efficiency was improved by over 200 times compared with pulsed mode, improving signal to noise ratio 10 times. HT ion mobility and TOF mass spectrometry provide an additional dimension of separation for complex samples without increasing the analysis time compared with conventional HPLC.

  3. Carbohydrate analysis of hemicelluloses by gas chromatography-mass spectrometry of acteylated methyl glycosides

    DEFF Research Database (Denmark)

    Sárossy, Zsuzsa; Plackett, David; Egsgaard, Helge

    2012-01-01

    A method based on gas chromatography–mass spectrometry analysis of acetylated methyl glycosides was developed in order to analyze monosaccharides obtained from various hemicelluloses. The derivatives of monosaccharide standards, arabinose, glucose, and xylose were studied in detail and 13C-labele......-labeled analogues were used for identification and quantitative analysis. Excellent chromatographic separation of the monosaccharide derivatives was found and identification of the anomeric configuration was feasible through a prepared and identified pure methyl 2,3,4,6-tetra......A method based on gas chromatography–mass spectrometry analysis of acetylated methyl glycosides was developed in order to analyze monosaccharides obtained from various hemicelluloses. The derivatives of monosaccharide standards, arabinose, glucose, and xylose were studied in detail and 13C...

  4. Multi-detection of corticosteroids in sports doping and veterinary control using high-resolution liquid chromatography/time-of-flight mass spectrometry

    NARCIS (Netherlands)

    Touber, M.E.; Engelen, M.C.; Georgakopoulus, C.; Rhijn, van J.A.; Nielen, M.W.F.

    2007-01-01

    A liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) method was developed using the latest high-resolution LC column technology, the ultra performance liquid chromatography (UPLC (TM)), and electrospray ionization (ESI) in the positive ion mode. Gradient UPLC separation conditions wer

  5. Diagnosis of glutaric aciduria type 1 by measuring 3-hydroxyglutaric acid in dried urine spots by liquid chromatography tandem mass spectrometry

    DEFF Research Database (Denmark)

    Al-Dirbashi, Osama Y; Kölker, Stefan; Ng, Dione;

    2011-01-01

    on stable isotope dilution gas chromatography mass spectrometry (GC-MS) and require extensive sample preparation. Here we describe a simple liquid chromatography tandem MS (LC-MS/MS) method to quantify this important metabolite in dried urine spots (DUS). This method is based on derivatization with 4-[2-(N...... enzymatic and molecular analyses to establish or refute the diagnosis of GA1....

  6. High-performance liquid chromatography-mass spectrometry for mapping and sequencing glycosaminoglycan-derived oligosaccharides

    OpenAIRE

    Volpi, Nicola; Linhardt, Robert J.

    2010-01-01

    Glycosaminoglycans (GAGs) have proven to be very difficult to analyze and characterize because of their high negative charge density, polydispersity and sequence heterogeneity. As the specificity of the interactions between GAGs and proteins results from the structure of these polysaccharides, an understanding of GAG structure is essential for developing a structure–activity relationship. Electrospray ionization (ESI) mass spectrometry (MS) is particularly promising for the analysis of oligos...

  7. Liquid chromatography mass spectrometry-based proteomics: Biological and technological aspects

    OpenAIRE

    Karpievitch, Yuliya V.; Polpitiya, Ashoka D.; Anderson, Gordon A.; Smith, Richard D.; Dabney, Alan R.

    2011-01-01

    Mass spectrometry-based proteomics has become the tool of choice for identifying and quantifying the proteome of an organism. Though recent years have seen a tremendous improvement in instrument performance and the computational tools used, significant challenges remain, and there are many opportunities for statisticians to make important contributions. In the most widely used “bottom-up” approach to proteomics, complex mixtures of proteins are first subjected to enzymati...

  8. Quantification of Modified Tyrosines in Healthy and Diabetic Human Urine using Liquid Chromatography/Tandem Mass Spectrometry

    OpenAIRE

    Kato, Yoji; Dozaki, Natsuko; Nakamura, Toshiyuki; Kitamoto, Noritoshi; Yoshida, Akihiro; Naito, Michitaka; Kitamura, Masayasu; Osawa, Toshihiko

    2008-01-01

    The quantification of urinary oxidized tyrosines, dityrosine (DiY), nitrotyrosine (NY), bromotyrosine (BrY), and dibromotyrosine (DiBrY), was accomplished by quadruple liquid chromatography-tandem mass spectrometry (LC/MS/MS). The sample was partially purified by solid phase extraction, and was then applied to the LC/MS/MS using multiple-reaction monitoring (MRM) methods. The analysis for the DiY quantification was done first. The residual samples were further butylated with n-butanol/HCl, an...

  9. ANALYSES OF QUINOLONE ANTIMICROBIALS IN HUMAN PLASMA BY CAPILLARY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY/FAST ATOM BOMBARDMENT MASS SPECTROMETRY

    OpenAIRE

    Hattori, Hideki; Suzuki, Osamu; Seno, Hiroshi; Ishii, Akira; Yamada, Takamichi

    1993-01-01

    Capillary high-performance liquid chromatography (HPLC) was combined with frit fast atom bombardment (FAB)-mass spectrometry (MS) , and a detailed procedure has been established for on-line analysis of ten quinolone antimicrobials in human plasma by the HPLC/FAB-MS. A special column switching device for concentration enabled injection of as large as a 500 μl sample; and the capillary column (0.5 mm i. d.) enabled introduction of its entire effluent to the frit interface of FAB-MS. These condi...

  10. Screening and determination of drugs in human saliva utilizing microextraction by packed sorbent and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Abdel-Rehim, Abbi; Abdel-Rehim, Mohamed

    2013-09-01

    This study presents a new method for collecting and handling saliva samples using an automated analytical microsyringe and microextraction by packed syringe (MEPS). The screening and determination of lidocaine in human saliva samples utilizing MEPS and liquid chromatography-tandem mass spectrometry (LC-MS/MS) were carried out. An exact volume of saliva could be collected. The MEPS C8 -cartridge could be used for 50 extractions before it was discarded. The extraction recovery was about 60%. The pharmacokinetic curve of lidocaine in saliva using MEPS-LC-MS/MS is reported.

  11. Rapid quantification of the metabolite of valacyclovir hydrochloride in human plasma by liquid chromatography-tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Objective To establish a rapid,sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of acyclovir (the metabolite of valacyclovir hydrochloride) in human plasma. Methods After addition of ganciclovir as internal standard (IS),plasma samples were prepared by one-step protein precipitation using acetonitrile as precipitant,followed by an isocratic elution with 0.1% formic acid solution-methanol (95∶5,v/v) on an Agilent ZORBAX SB-C18 (150mm×2.1mm i.d.,3....

  12. [Progress in quantitative methods based on liquid chromatography-mass spectrometry for drug metabolizing enzymes in human liver microsomes].

    Science.gov (United States)

    Wang, Huanhuan; Lu, Yayao; Peng, Bo; Qian, Xiaohong; Zhang, Yangjun

    2015-06-01

    Cytochrome P450 (CYP) enzymes and uridine 5-diphospho-glucuronosyltransferase (UGT) enzymes are critical enzymes for drug metabolism. Both chemical drugs and traditional Chinese medicines are converted to more readily excreted compounds by drug metabolizing enzymes in human livers. Because of the disparate expression of CYP and UGT enzymes among different individuals, accurate quantification of these enzymes is essential for drug pharmacology, drug-drug interactions and drug clinical applications. The research progress in quantitative methods based on liquid chromatography-mass spectrometry for drug metabolizing enzymes in human liver microsomes in the recent decade is reviewed.

  13. Detection of trace levels of triclopyr using capillary gas chromatography-electron-capture negative-ion chemical ionization mass spectrometry.

    Science.gov (United States)

    Begley, P; Foulger, B E

    1988-04-01

    Triclopyr, after esterification, is shown to be a suitable candidate for detection by gas chromatography-electron-capture negative-ion chemical ionization mass spectrometry forming a characteristic carboxylate anion which offers a high detection sensitivity. A detection limit of 70 fg reaching the ionizer is indicated. Low backgrounds and an absence of chemical interferences are shown for vegetation extracts, using a simple method of extraction and derivatisation. A similar behaviour is demonstrated for 2,4-D and 2,4,5-T. PMID:3379116

  14. New Potential Biomarker for Methasterone Misuse in Human Urine by Liquid Chromatography Quadrupole Time of Flight Mass Spectrometry

    Science.gov (United States)

    Zhang, Jianli; Lu, Jianghai; Wu, Yun; Wang, Xiaobing; Xu, Youxuan; Zhang, Yinong; Wang, Yan

    2016-01-01

    In this study, methasterone urinary metabolic profiles were investigated by liquid chromatography quadrupole time of flight mass spectrometry (LC-QTOF-MS) in full scan and targeted MS/MS modes with accurate mass measurement. A healthy male volunteer was asked to take the drug and liquid–liquid extraction was employed to process urine samples. Chromatographic peaks for potential metabolites were hunted out with the theoretical [M − H]− as a target ion in a full scan experiment and actual deprotonated ions were studied in targeted MS/MS experiment. Fifteen metabolites including two new sulfates (S1 and S2), three glucuronide conjugates (G2, G6 and G7), and three free metabolites (M2, M4 and M6) were detected for methasterone. Three metabolites involving G4, G5 and M5 were obtained for the first time in human urine samples. Owing to the absence of helpful fragments to elucidate the steroid ring structure of methasterone phase II metabolites, gas chromatography mass spectrometry (GC-MS) was employed to obtain structural information of the trimethylsilylated phase I metabolite released after enzymatic hydrolysis and the potential structure was inferred using a combined MS method. Metabolite detection times were also analyzed and G2 (18-nor-17β-hydroxymethyl-2α, 17α-dimethyl-androst-13-en-3α-ol-ξ-O-glucuronide) was thought to be new potential biomarker for methasterone misuse which can be detected up to 10 days. PMID:27669235

  15. New Potential Biomarker for Methasterone Misuse in Human Urine by Liquid Chromatography Quadrupole Time of Flight Mass Spectrometry.

    Science.gov (United States)

    Zhang, Jianli; Lu, Jianghai; Wu, Yun; Wang, Xiaobing; Xu, Youxuan; Zhang, Yinong; Wang, Yan

    2016-01-01

    In this study, methasterone urinary metabolic profiles were investigated by liquid chromatography quadrupole time of flight mass spectrometry (LC-QTOF-MS) in full scan and targeted MS/MS modes with accurate mass measurement. A healthy male volunteer was asked to take the drug and liquid-liquid extraction was employed to process urine samples. Chromatographic peaks for potential metabolites were hunted out with the theoretical [M - H](-) as a target ion in a full scan experiment and actual deprotonated ions were studied in targeted MS/MS experiment. Fifteen metabolites including two new sulfates (S1 and S2), three glucuronide conjugates (G2, G6 and G7), and three free metabolites (M2, M4 and M6) were detected for methasterone. Three metabolites involving G4, G5 and M5 were obtained for the first time in human urine samples. Owing to the absence of helpful fragments to elucidate the steroid ring structure of methasterone phase II metabolites, gas chromatography mass spectrometry (GC-MS) was employed to obtain structural information of the trimethylsilylated phase I metabolite released after enzymatic hydrolysis and the potential structure was inferred using a combined MS method. Metabolite detection times were also analyzed and G2 (18-nor-17β-hydroxymethyl-2α, 17α-dimethyl-androst-13-en-3α-ol-ξ-O-glucuronide) was thought to be new potential biomarker for methasterone misuse which can be detected up to 10 days. PMID:27669235

  16. Tissue-specific metabolite profiling of Cyperus rotundus L. rhizomes and (+)-nootkatone quantitation by laser microdissection, ultra-high-performance liquid chromatography-quadrupole time-of-flight mass spectrometry, and gas chromatography-mass spectrometry techniques.

    Science.gov (United States)

    Jaiswal, Yogini; Liang, Zhitao; Guo, Ping; Ho, Hing-Man; Chen, Hubiao; Zhao, Zhongzhen

    2014-07-23

    Cyperus rotundus L. is a plant species commonly found in both India and China. The caused destruction of this plant is of critical concern for agricultural produce. Nevertheless, it can serve as a potential source of the commercially important sesquiterpenoid (+)-nootkatone. The present work describes comparative metabolite profiling and (+)-nootkatone content determination in rhizome samples collected from these two countries. Laser dissected tissues, namely, the cortex, hypodermal fiber bundles, endodermis, amphivasal vascular bundles, and whole rhizomes were analyzed by ultra-high-performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UHPLC-QTOF MS). Gas chromatography-mass spectrometry (GC-MS) analysis was used for profiling of essential oil constituents and quantitation of (+)-nootkatone. The content of (+)-nootkatone was found to be higher in samples from India (30.47 μg/10 g) compared to samples from China (21.72 μg/10 g). The method was validated as per International Conference on Harmonisation (ICH) guidelines (Q2 R1). The results from this study can be applied for quality control and efficient utilization of this terpenoid-rich plant for several applications in food-based industries. PMID:24938835

  17. Chemical profiling and quantification of Gua-Lou-Gui-Zhi decoction by high performance liquid chromatography/quadrupole-time-of-flight mass spectrometry and ultra-performance liquid chromatography/triple quadrupole mass spectrometry.

    Science.gov (United States)

    Xu, Wen; Huang, Mingqing; Li, Huang; Chen, Xianwen; Zhang, Yuqin; Liu, Jie; Xu, Wei; Chu, Kedan; Chen, Lidian

    2015-04-01

    Gua-Lou-Gui-Zhi decoction (GLGZD) is a classical formula of traditional Chinese medicine, which has been commonly used to treat dysfunction after stroke, epilepsy and spinal cord injury. In this study, a systematic method was established for chemical profiling and quantification analysis of the major constituents in GLGZD. For qualitative analysis, a method of high performance liquid chromatography/quadrupole time-of-flight mass spectrometry (Q-TOF MS) was developed. 106 compounds, including monoterpene glycosides, galloyl glucoses, phenolic acids, flavonoids, gingerols and triterpene saponins were identified or tentatively presumed by comparison with reference standards or literature data. According to the qualitative results, a new quantitative analysis method of ultra-performance liquid chromatography/triple quadrupole mass spectrometry (QqQ-MS) was established. 24 representative compounds were simultaneously detected in 10 batches of GLGZD samples in 7.5 min. The calibration curves for all analytes showed good linearity (r>0.9959) within the test ranges. The LODs and the LOQs were less than 30.6 and 70.9 ng/mL, respectively. The RSDs of intra- and inter-day precision, repeatability and stability were below 3.64%, 4.85%, 4.84% and 3.87%, respectively. The overall recoveries ranged from 94.94% to 103.66%, with the RSDs within 5.12%. This study established a high sensitive and efficient method for the integrating quality control, including identification and quantification of Chinese medicinal preparation. PMID:25710597

  18. Forensic Mass Spectrometry

    Science.gov (United States)

    Hoffmann, William D.; Jackson, Glen P.

    2015-07-01

    Developments in forensic mass spectrometry tend to follow, rather than lead, the developments in other disciplines. Examples of techniques having forensic potential born independently of forensic applications include ambient ionization, imaging mass spectrometry, isotope ratio mass spectrometry, portable mass spectrometers, and hyphenated chromatography-mass spectrometry instruments, to name a few. Forensic science has the potential to benefit enormously from developments that are funded by other means, if only the infrastructure and personnel existed to adopt, validate, and implement the new technologies into casework. Perhaps one unique area in which forensic science is at the cutting edge is in the area of chemometrics and the determination of likelihood ratios for the evaluation of the weight of evidence. Such statistical techniques have been developed most extensively for ignitable-liquid residue analyses and isotope ratio analysis. This review attempts to capture the trends, motivating forces, and likely impact of developing areas of forensic mass spectrometry, with the caveat that none of this research is likely to have any real impact in the forensic community unless: (a) The instruments developed are turned into robust black boxes with red and green lights for positives and negatives, respectively, or (b) there are PhD graduates in the workforce who can help adopt these sophisticated techniques.

  19. Simultaneous Determination of 25 Common Pharmaceuticals in Whole Blood Using Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Marie Katrine Klose; Johansen, Sys Stybe

    2012-01-01

    An ultra-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of 25 common pharmaceuticals in whole blood. The selected pharmaceuticals represent the most frequently detected drugs in our forensic laboratory with basic properties...... such as analgesics, antidepressants, antihistamines, antihypertensives, antipsychotics and ß-blockers. Whole blood samples were extracted with butyl acetate after adjusting pH with 2M NaOH. The target analytes were separated on a 100 × 2.1 mm ACQUITY BEH 1.7 µm C18 column by a formic acid/acetonitrile gradient...... elution using a Waters ACQUITY Ultra-Performance Liquid Chromatography system. Quantification was performed on a Waters tandem quadrupole ACQUITY TQD using multiple reaction monitoring in positive mode. The analytes were eluted within 11 min. The limit of quantification (LOQ) ranged from 0.002 to 0.01 mg...

  20. Gas and liquid chromatography with inductively coupled plasma mass spectrometry detection for environmental speciation analysis — advances and limitations

    Science.gov (United States)

    Szpunar, Joanna; McSheehy, Shona; Połeć, Kasia; Vacchina, Véronique; Mounicou, Sandra; Rodriguez, Isaac; Łobiński, Ryszard

    2000-07-01

    Recent advances in the coupling of gas chromatography (GC) and high performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICP MS) and their role in trace element speciation analysis of environmental materials are presented. The discussion is illustrated with three research examples concerning the following topics: (i) development and coupling of multicapillary microcolumn GC with ICP MS for speciation of organotin in sediment and biological tissue samples; (ii) speciation of arsenic in marine algae by size-exclusion-anion-exchange HPLC-ICP MS; and (iii) speciation of cadmium in plant cell cultures by size-exclusion HPLC-ICP MS. Particular attention is paid to the problem of signal identification in ICP MS chromatograms; the potential of electrospray MS/MS for this purpose is highlighted.

  1. Determination of cholesterol and four phytosterols in foods without derivatization by gas chromatography-tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Yan-Zong Chen

    2015-12-01

    Full Text Available In this study, a method for determination of cholesterol and four phytosterols by gas chromatography coupled with electron impact ionization mode–tandem mass spectrometry without derivatization in general food was developed. The sample was saponified with 7.5% KOH in methanol. After heating on hot plate and reflux for 60 minutes, the saponified portion was extracted with n-hexane/petroleum ether (50:50, v/v. The extracts were evaporated with rotary evaporator and then redissolved with tetrahydrofuran. The tetrahydrofuran layer was transferred into an injection vial and analyzed by gas chromatography on a 30 m VF-5 column. Limit of quantification was 2 mg/kg. Recoveries of cholesterol and four phytosterols from general food were between 91% and 100%.

  2. Determination of methyl tert-butyl ether (MTBE) in Chinese fuels by gas chromatography/mass spectrometry and gas chromatography/flame ionization detector

    Institute of Scientific and Technical Information of China (English)

    LIU Jie-min; CHENG Wei; WEN Mei-juan; JIANG Gui-bin

    2004-01-01

    A method was developed to determine the concentration of methyl tert-butyl ether(MTBE) in gasoline,diesel and heating oil by gas chromatography(GC) with mass spectrometry(GC-MS) or flame ionization detection (FID). The diluted gasoline was directly injected into the GC, and the complete separation of MTBE from co-eluting hydrocarbons was not required. GC/MS or GC/FID method can be used to analyze MTBE in different concentration range and have good consistency.

  3. Coal liquefaction process streams characterization and evaluation. Characterization of coal-derived materials by field desorption mass spectrometry, two-dimensional nuclear magnetic resonance, supercritical fluid extraction, and supercritical fluid chromatography/mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, J.A.; Linehan, J.C.; Robins, W.H. [Battelle Pacific Northwest Lab., Richland, WA (United States)

    1992-07-01

    Under contract from the DOE , and in association with CONSOL Inc., Battelle, Pacific Northwest Laboratory (PNL) evaluated four principal and several complementary techniques for the analysis of non-distillable direct coal liquefaction materials in support of process development. Field desorption mass spectrometry (FDMS) and nuclear magnetic resonance (NMR) spectroscopic methods were examined for potential usefulness as techniques to elucidate the chemical structure of residual (nondistillable) direct coal liquefaction derived materials. Supercritical fluid extraction (SFE) and supercritical fluid chromatography/mass spectrometry (SFC/MS) were evaluated for effectiveness in compound-class separation and identification of residual materials. Liquid chromatography (including microcolumn) separation techniques, gas chromatography/mass spectrometry (GC/MS), mass spectrometry/mass spectrometry (MS/MS), and GC/Fourier transform infrared (FTIR) spectroscopy methods were applied to supercritical fluid extracts. The full report authored by the PNL researchers is presented here. The following assessment briefly highlights the major findings of the project, and evaluates the potential of the methods for application to coal liquefaction materials. These results will be incorporated by CONSOL into a general overview of the application of novel analytical techniques to coal-derived materials at the conclusion of CONSOL`s contract.

  4. Determination of tetracycline antibiotic residues in edible swine tissues by liquid chromatography with spectrofluorometric detection and confirmation by mass spectrometry.

    Science.gov (United States)

    Pena, Angelina; Lino, Celeste M; Alonso, Rosa; Barceló, Damia

    2007-06-27

    A sensitive and specific method is described for the simultaneous determination of oxytetracycline, tetracycline (TC), and chlortetracycline residues in edible swine tissues, by combining liquid chromatography with spectrofluorometric and mass spectrometry detection. The procedure involved a preliminary extraction with EDTA-McIlvaine buffer acidified at pH 4.0, followed by solid-phase extraction cleanup using a polymeric sorbent. The liquid chromatography analysis was performed with spectrofluorometric detection after postcolumn derivatization with magnesium ions. The limits of quantification were 50 microg/kg for muscle and 100 microg/kg for kidney tissues. The recovery values were greater than 77.8% for muscle and 65.1% for kidney. The method has been successfully used for the quantification of tetracyclines in swine tissues samples. The selective liquid chromatography mass spectrometric analysis for confirmation of oxytetracycline in one positive swine muscle sample was made by atmospheric pressure chemical ionization (APCI). The APCI mass spectra of the TCs gave the protonated molecular ion and two typical fragment ions, required for their confirmation in single ion monitoring scan mode in animal tissues. PMID:17550268

  5. Identification and quantification of bleomycin in serum and tumor tissue by liquid chromatography coupled to high resolution mass spectrometry.

    Science.gov (United States)

    Kosjek, Tina; Krajnc, Anja; Gornik, Tjasa; Zigon, Dusan; Groselj, Ales; Sersa, Gregor; Cemazar, Maja

    2016-11-01

    Bleomycin is a cytotoxic antibiotic available as a compost of structurally strongly related glycopeptides, which is in vivo found chelated with several metals. Its pharmacotherapy has merely been based on experimental dose - response data, whereas its biodistribution and pharmacokinetics remain fundamentally unknown. This is reasoned by an absence of a specific and sensitive mass spectrometry-based analytical method for its determination in biological tissues. We herein reveal the results of our study on the mass spectrometric behavior of two main bleomycin fractions A2 and B2, including their metal complexes, particularly the predominant copper chelates. In the electrospray ion source bleomycin forms double charged species, where for the metal-free fraction A2 and its copper complex m/z 707.76 and m/z 707.21 are seen, respectively. Hence, the second isotopic ion of the chelate (m/z 707.71) nearly coincides with the first isotopic ion of the metal-free fraction. This phenomenon can only be followed by high-resolution mass spectrometry, and is considered the plausible reason, why the attempts to determine bleomycin with mass spectrometry have been so scarce. The presented paper further describes a sensitive and selective liquid chromatography - mass spectrometry analytical method for determination of bleomycin in serum and tumor tissues. This newly developed method was employed for bleomycin pharmacokinetic studies in serum and tumors of laboratory animals. Additionally, the method was employed for determination of bleomycin pharmacokinetic parameters in elderly patients in order to determine the effective therapeutic window of electrochemotherapy with bleomycin. PMID:27591601

  6. Elemental labelling combined with liquid chromatography inductively coupled plasma mass spectrometry for quantification of biomolecules: A review

    International Nuclear Information System (INIS)

    Highlights: ► Survey of bio-analytical approaches utilizing biomolecule labelling. ► Detailed discussion of methodology and chemistry of elemental labelling. ► Biomedical and bio-analytical applications of elemental labelling. ► FI-ICP-MS and LC–ICP-MS for quantification of elemental labelled biomolecules. ► Review of selected applications. - Abstract: This article reviews novel quantification concepts where elemental labelling is combined with flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS) or liquid chromatography inductively coupled plasma mass spectrometry (LC–ICP-MS), and employed for quantification of biomolecules such as proteins, peptides and related molecules in challenging sample matrices. In the first sections an overview on general aspects of biomolecule quantification, as well as of labelling will be presented emphasizing the potential, which lies in such methodological approaches. In this context, ICP-MS as detector provides high sensitivity, selectivity and robustness in biological samples and offers the capability for multiplexing and isotope dilution mass spectrometry (IDMS). Fundamental methodology of elemental labelling will be highlighted and analytical, as well as biomedical applications will be presented. A special focus will lie on established applications underlining benefits and bottlenecks of such approaches for the implementation in real life analysis. Key research made in this field will be summarized and a perspective for future developments including sophisticated and innovative applications will given.

  7. [Simultaneous determination of 16 organic acids in feed additives by on-line enrichment and ion chromatography-mass spectrometry].

    Science.gov (United States)

    Xiong, Zhiyu; Dong, Ying; Zhou, Hongbin; Yu, Yang; Li, Jing; Sun, Li

    2014-02-01

    A novel analytical method for simultaneous determination of sixteen organic acids by on-line enrichment and ion chromatography-mass spectrometry (IC-MS) was developed. Online enrichment and separation of the organic acids were performed by ion chromatography on a homemade enrichment column and a homemade separation column. The qualitative and quantitative analyses of the organic acids were performed by mass spectrometry in selected ion monitoring (SIM) mode on the basis of atmospheric pressure chemical ionization (APCI) source in negative mode. The sample of 200 microL was injected for the analysis, and the on-line enrichment time was 3 min. The sodium hydroxide solution was used as a gradient elution system. The two columns made it possible to have a low limit of detection due to the good enrichment and separation capability. The sixteen organic acids were separated completely within 30 min. All curves showed good linearity within the test concentration ranges. The limits of detection (LODs) were between 0.01 and 0.22 mg/L, and the average recoveries were between 70.6% and 110.8%. The relative standard deviations (RSDs) were less than 6.3%. The results indicate that this method is simple, rapid, sensitive and accurate for the determination of the organic acids in feed additives.

  8. Simultaneous Determination of Hexoestrol, Diethylstilbestrol, Estrone and 17-Beta-estradiol in Feed by Gas Chromatography-mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    Huo Feng; Li Ning; Lin Xiao-Li

    2016-01-01

    A method was developed for the simultaneous determination of four kinds of estrogens (hexoestrol, diethylstilbestrol, estrone, and 17-beta-estradiol) in feed by gas chromatography-mass spectrometry (GC-MS). After the sample was extracted by ethyl ether and cleaned-up on HLB phase extraction column, four kinds of estrogens were derived and quantified in gas chromatography-mass spectrometry. The results showed that the linear detectable ranged from 2.5 ng•mL-1 to 250 ng•mL-1 for hexoestrol and from 5 ng•mL-1 to 500 ng•mL-1 for three other estrogens with the correlation coefficients (R2) were no less than 0.990. The recoveries were in the range of 76.34%-96.33% and the relative standard deviation was no more than 22.7%. The limits of quantitation (LOQ) for all analytics were between 10 ug•kg-1 and 20 ug•kg-1. The method was accurate and sensitive and could meet the actual requirements for the analyses of feed samples.

  9. Determination of azithromycin residue in pork using a molecularly imprinted monolithic microcolumn coupled to liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Tong; Yang, Haicui; Jin, Zhen; Liu, Qingying; Song, Xuqin; He, Limin; Fang, Binghu; Meng, Chenying

    2016-04-01

    Using spiramycin as a dummy template, a molecularly imprinted polymer monolithic micro-column with high selection to azithromycin was prepared in a micropipette tip. The imprinting factor of the monolithic micro-column prepared was approximately 2.67 and the morphological structure of the polymers was characterized by scanning electron microscopy. A simple, sensitive, and reproducible method based on the imprinted monolithic micro-column coupled to liquid chromatography with tandem mass spectrometry was developed for determining the residues of azithromycin in pork. Pork samples were extracted with acetonitrile, cleaned up under the optimal monolithic micro-column conditions, and analyzed using liquid chromatography with tandem mass spectrometry in the multiple reaction monitoring mode. The assay exhibited a linear dynamic range of 0.50-50 μg/L with the correlation coefficient (r(2) ) above 0.99. In the three spiking levels of 0.50, 1.0, and 10 μg/kg, the average recoveries of azithromycin from pork samples were between 85.8 and 96.5% with a relative standard deviation below 10%. The limit of detection and limit of quantitation were 0.03 and 0.1 μg/kg, respectively. PMID:26854282

  10. Analysis of capsaicin and dihydrocapsaicin in peppers and pepper sauces by solid phase microextraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Peña-Alvarez, Araceli; Ramírez-Maya, Erika; Alvarado-Suárez, Luís Angel

    2009-04-01

    A simple method for the analysis of capsaicin and dihydrocapsaicin in peppers and pepper sauces by solid phase microextraction-gas chromatography-mass spectrometry has been developed. A novel device was designed for direct extraction solid phase microextraction in order to avoid damage to the fiber. The analysis was performed without derivatization for the gas chromatography-mass spectrometry analysis. Selection fiber, extraction temperature, extraction time and pH, were optimized. The method was linear in the range 0.109-1.323 microg/mL for capsaicin and 0.107-1.713 microg/mL for dihydrocapsaicin with correlation coefficient up to r=0.9970 for both capsaicinoids. The precision of the method was less than 10%. The method was applied to the analysis of 11 varieties of peppers and four pepper sauces. A broad range of capsaicin (55.0-25 459 microg/g) and dihydrocapsaicin (93-1 130 microg/g) was found in the pepper and pepper sauces samples (4.3-717.3 and 1.0-134.8 microg/g), respectively.

  11. Determination of vanillin, ethyl vanillin, and coumarin in infant formula by liquid chromatography-quadrupole linear ion trap mass spectrometry.

    Science.gov (United States)

    Shen, Yan; Han, Chao; Liu, Bin; Lin, Zhengfeng; Zhou, Xiujin; Wang, Chengjun; Zhu, Zhenou

    2014-02-01

    A simple, precise, accurate, and validated liquid chromatography-quadrupole linear ion trap mass spectrometry method was developed for the determination of vanillin, ethyl vanillin, and coumarin in infant formula samples. Following ultrasonic extraction with methanol/water (1:1, vol/vol), and clean-up on an HLB solid-phase extraction cartridge (Waters Corp., Milford, MA), samples were separated on a Waters XSelect HSS T3 column (150 × 2.1-mm i.d., 5-μm film thickness; Waters Corp.), with 0.1% formic acid solution-acetonitrile as mobile phase at a flow rate of 0.25 mL/min. Quantification of the target was performed by the internal standard approach, using isotopically labeled compounds for each chemical group, to correct matrix effects. Data acquisition was carried out in multiple reaction monitoring transitions mode, monitoring 2 multiple reaction monitoring transitions to ensure an accurate identification of target compounds in the samples. Additional identification and confirmation of target compounds were performed using the enhanced product ion modus of the linear ion trap. The novel liquid chromatography-quadrupole linear ion trap mass spectrometry platform offers the best sensitivity and specificity for characterization and quantitative determination of vanillin, ethyl vanillin, and coumarin in infant formula and fulfills the quality criteria for routine laboratory application.

  12. Application of integrated comprehensive/multidimensional gas chromatography with mass spectrometry and olfactometry for aroma analysis in wine and coffee.

    Science.gov (United States)

    Chin, Sung-Tong; Eyres, Graham T; Marriott, Philip J

    2015-10-15

    Component coelution in chromatographic analysis complicates identification and attribution of individual odour-active volatile molecules in complex multi-component samples. An integrated system incorporating comprehensive two-dimensional gas chromatography (GC × GC) and multidimensional gas chromatography (MDGC), with flame ionisation, olfactometry and mass spectrometry detection was developed to circumvent data correlation across different systems. Identification of potent odorants in Shiraz wine and the headspace of ground coffee are demonstrated as selected applications. Multiple solid-phase microextraction (SPME) sampling with GC-O located odour-active regions; GC × GC established the complexity of odour-active regions; MDGC provided high-resolution separation for each region; simultaneous 'O' and MS detection completed the analysis for target resolved peaks. Seven odour regions in Shiraz were analysed with MDGC-O/MS detection, revealing 11 odour volatiles through matching of mass spectrometry and retention indices from both separating dimensions, including acetic acid; octen-3-ol; ethyl octanoate; methyl-2-oxo-nonanoate; butanoic acid, 2-methylbutanoic acid, and 3-methylbutanoic acid; 3-(methylthio)-1-propanol; hexanoic acid; β-damascenone; and ethyl-3-phenylpropanoate. A capsicum odour in ground coffee was identified as 2-methoxy-3-isobutylpyrazine with a 5-fold increase in S/N of the odorant when acquired using a 6-time cumulative SPME sampling approach.

  13. High Performance Liquid Chromatography Tandem Mass Spectrometry Measurement of Bimatoprost, Latanoprost and Travoprost in Eyelash Enhancing Cosmetic Serums

    Directory of Open Access Journals (Sweden)

    Emilia Marchei

    2016-02-01

    Full Text Available Most common prostaglandin analogs, bimatoprost, latanoprost and travoprost, are licensed for the reduction of elevated intraocular pressure in patients with open angle glaucoma and ocular hypertension, but their non approved use as eyelash enhancers is becoming popular, especially in patients with eyelashes hypotrichosis. A fast and sensitive high performance liquid chromatography tandem mass spectrometry method was developed for the measurement of bimatoprost, latanoprost and travoprost in cosmetic serums freely web-sold to increase eyelash length, thickness and darkness. The analytes and the internal standard (reserpine were separated by reversed phase chromatography with 5 mM ammonium acetate with 0.02% formic acid (mobile phase A and 5 mM ammonium acetate in acetonitrile/water (95/5; v/v with 0.02% formic acid (mobile phase B by gradient elution and detected with tandem mass spectrometry operated in multiple reaction monitoring mode. Linearity between 1 and 500 μg/g shows good correlation coefficients (r2 = 0.99 for all substances. Analytical recovery of analytes under investigation were always higher than 90% and intra-assay and inter-assay precision and accuracy always better than 11%. This method was successfully applied to analyze cosmetic serums freely sold on the Internet websites.

  14. An Ultra-Trace Analysis Technique for SF6 Using Gas Chromatography with Negative Ion Chemical Ionization Mass Spectrometry.

    Science.gov (United States)

    Jong, Edmund C; Macek, Paul V; Perera, Inoka E; Luxbacher, Kray D; McNair, Harold M

    2015-07-01

    Sulfur hexafluoride (SF6) is widely used as a tracer gas because of its detectability at low concentrations. This attribute of SF6 allows the quantification of both small-scale flows, such as leakage, and large-scale flows, such as atmospheric currents. SF6's high detection sensitivity also facilitates greater usage efficiency and lower operating cost for tracer deployments by reducing quantity requirements. The detectability of SF6 is produced by its high molecular electronegativity. This property provides a high potential for negative ion formation through electron capture thus naturally translating to selective detection using negative ion chemical ionization mass spectrometry (NCI-MS). This paper investigates the potential of using gas chromatography (GC) with NCI-MS for the detection of SF6. The experimental parameters for an ultra-trace SF6 detection method utilizing minimal customizations of the analytical instrument are detailed. A method for the detection of parts per trillion (ppt) level concentrations of SF6 for the purpose of underground ventilation tracer gas analysis was successfully developed in this study. The method utilized a Shimadzu gas chromatography with negative ion chemical ionization mass spectrometry system equipped with an Agilent J&W HP-porous layer open tubular column coated with an alumina oxide (Al2O3) S column. The method detection limit (MDL) analysis as defined by the Environmental Protection Agency of the tracer data showed the method MDL to be 5.2 ppt. PMID:25452581

  15. Characterization of oncogene-induced metabolic alterations in hepatic cells by using ultrahigh performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Tang, Zhi; Cao, Tingting; Lin, Shuhai; Fu, Li; Li, Shangfu; Guan, Xin-Yuan; Cai, Zongwei

    2016-05-15

    Elucidation of altered metabolic pathways by using metabolomics may open new avenues for basic research on disease mechanisms and facilitate the development of novel therapeutic strategies. Here, we report the development of ultrahigh performance liquid chromatography-tandem mass spectrometry-based metabolomics platform with capability of measuring both cationic and anionic intermediates in cellular metabolism. The platform was established based on the hydrophobic ion-pairing interaction chromatography coupled with tandem mass spectrometry in multiple reaction monitoring (MRM) mode. The MRM transitions were created and optimized via energy-resolved collision-induced dissociation experiments, serving as an essential reference point for the quantification and identification. For chromatographic separation, application of hydrophobic ion-pairing interaction led to dramatic enhancement on retention of water-soluble metabolites and provision of good peak shapes. Two volatile ion-pairing reagents, namely heptafluorobutyric acid and tributylamine, were used with dedicated C18 columns as complementary separation systems coupled with the MRM analysis, allowing measurement of the metabolites of interest at nanomolar levels. The developed platform was successfully applied to investigate the altered metabolism in hepatic cells with over-expression of an oncogene, thus can provide important information on the rewired metabolism. PMID:26992502

  16. Potential of needle trap microextraction-portable gas chromatography-mass spectrometry for measurement of atmospheric volatile compounds

    Science.gov (United States)

    Feijó Barreira, Luís Miguel; Xue, Yu; Duporté, Geoffroy; Parshintsev, Jevgeni; Hartonen, Kari; Jussila, Matti; Kulmala, Markku; Riekkola, Marja-Liisa

    2016-08-01

    Volatile organic compounds (VOCs) play a key role in atmospheric chemistry and physics. They participate in photochemical reactions in the atmosphere, which have direct implications on climate through, e.g. aerosol particle formation. Forests are important sources of VOCs, and the limited resources and infrastructures often found in many remote environments call for the development of portable devices. In this research, the potential of needle trap microextraction and portable gas chromatography-mass spectrometry for the study of VOCs at forest site was evaluated. Measurements were performed in summer and autumn 2014 at the Station for Measuring Ecosystem-Atmosphere Relations (SMEAR II) in Hyytiälä, Finland. During the first part of the campaign (summer) the applicability of the developed method was tested for the determination of monoterpenes, pinonaldehyde, aldehydes, amines and anthropogenic compounds. The temporal variation of aerosol precursors was determined, and evaluated against temperature and aerosol number concentration data. The most abundant monoterpenes, pinonaldehyde and aldehydes were successfully measured, their relative amounts being lower during days when particle number concentration was higher. Ethylbenzene, p- and m-xylene were also found when wind direction was from cities with substantial anthropogenic activity. An accumulation of VOCs in the snow cover was observed in the autumn campaign. Results demonstrated the successful applicability of needle trap microextraction and portable gas chromatography-mass spectrometry for the rapid in situ determination of organic gaseous compounds in the atmosphere.

  17. Speciation of four selenium compounds using high performance liquid chromatography with on-line detection by inductively coupled plasma mass spectrometry or flame atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Pedersen, Gitte Alsing; Larsen, Erik Huusfeldt

    1997-01-01

    An analytical method for the speciation of selenomethionine, selenocystine, selenite and selenate by high performance liquid chromatography (HPLC) with atomic spectrometric detection is presented. An organic polymeric strong anion exchange column was used as the stationary phase in combination...... with an aqueous solution of 6 mmol L-1 of salicylate ion at pH 8.5 as the mobile phase which allowed the isocratic separation of the four selenium analytes within 8 minutes. The separated selenium species were detected on-line by flame atomic absorption spectrometry (FAAS) or inductively coupled plasma mass...

  18. Qualitative and Quantitative Analysis of Volatile Components of Zhengtian Pills Using Gas Chromatography Mass Spectrometry and Ultra-High Performance Liquid Chromatography

    Science.gov (United States)

    Liu, Cui-ting; Zhang, Min; Yan, Ping; Liu, Hai-chan; Liu, Xing-yun; Zhan, Ruo-ting

    2016-01-01

    Zhengtian pills (ZTPs) are traditional Chinese medicine (TCM) which have been commonly used to treat headaches. Volatile components of ZTPs extracted by ethyl acetate with an ultrasonic method were analyzed by gas chromatography mass spectrometry (GC-MS). Twenty-two components were identified, accounting for 78.884% of the total components of volatile oil. The three main volatile components including protocatechuic acid, ferulic acid, and ligustilide were simultaneously determined using ultra-high performance liquid chromatography coupled with diode array detection (UHPLC-DAD). Baseline separation was achieved on an XB-C18 column with linear gradient elution of methanol-0.2% acetic acid aqueous solution. The UHPLC-DAD method provided good linearity (R2 ≥ 0.9992), precision (RSD protocatechuic acid, ferulic acid, and ligustilide, in 13 batches of ZTPs, which is suitable for discrimination and quality assessment of ZTPs. PMID:26904360

  19. Characterization of odor-active compounds of various Chrysanthemum essential oils by gas chromatography-olfactometry, gas chromatography-mass spectrometry and their correlation with sensory attributes.

    Science.gov (United States)

    Xiao, Zuobing; Fan, Binbin; Niu, Yunwei; Wu, Minling; Liu, Junhua; Ma, Shengtao

    2016-01-15

    Volatiles of five kinds of Chrysanthemum essential oils with different manufactures were characterized by descriptive sensory analysis, gas chromatography-olfactometry (GC-O), gas chromatography-mass spectrometry (GC-MS) and statistics analysis. Six sensory attributes (floral, woody, grassy, fruity, sour and minty) were selected to assess Chrysanthemum essential oils. A total of 38 volatile compounds were detected and quantified using standard substances by GC-O and GC-MS. Terpenes constituted the largest chemical group among the volatiles of the essential oils. Then partial least squares regression (PLSR) was used to elucidate the relationship between sensory attributes and aroma compounds. The result showed that α-pinene, β-thujene, α-terpinolen, β-cubebene, caryophyllene, (Z)β-farnesene, (-)-spathulenol, linalool, camphor, camphene, 4-terpineol, Z-citral and 4-isopropyltoluene were typical aroma compounds covaried with characteristic aroma of Chrysanthemum essential oils. PMID:26735711

  20. Determination of endogenous ethanol in blood and breath by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Jones, A W; Mårdh, G; Anggård, E

    1983-01-01

    We describe methods for the determination of endogenous ethanol in biological specimens from healthy abstaining subjects. The analytical methods were headspace gas chromatography (GC) for plasma samples and gas chromatography-mass spectometry (GC/MS) with deuterium labelled species 2H3-ethanol and 2H5-ethanol as internal standards for breath analysis. Ethanol in rebreathed air was about 10% higher than in directly analysed end-expired alveolar air. Known volumes of rebreathed air were passed through a liquid-N2 freeze trap and the volatile constituents of breath were concentrated prior to analysis by GC or GC/MS. Besides endogenous ethanol, peaks were seen on the chromatograms for methanol, acetone and acetaldehyde as well as several as yet unidentified substances. The endogenous alcohols ethanol and methanol were confirmed from their mass chromatograms and the GC/MS profile also indicated the presence of endogenous propan-1-ol. The concentration of endogenous ethanol in plasma showed wide inter-subject variations ranging from below detection limits to 1.6 micrograms/ml (34.8 mumol/l) and with mean +/- SD of 0.39 +/- 0.45 micrograms/ml (8.5 +/- 9.8 mumol/l). We aim to characterise further the role of endogenous ethanol with the main focus on dynamic aspects such as the rate of formation and turnover.

  1. Targeted Chiral Analysis of Bioactive Arachidonic Acid Metabolites Using Liquid-Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Clementina Mesaros

    2012-04-01

    Full Text Available A complex structurally diverse series of eicosanoids arises from the metabolism of arachidonic acid. The metabolic profile is further complicated by the enantioselectivity of eicosanoid formation and the variety of regioisomers that arise. In order to investigate the metabolism of arachidonic acid in vitro or in vivo, targeted methods are advantageous in order to distinguish between the complex isomeric mixtures that can arise by different metabolic pathways. Over the last several years this targeted approach has become more popular, although there are still relatively few examples where chiral targeted approaches have been employed to directly analyze complex enantiomeric mixtures. To efficiently conduct targeted eicosanoid analyses, LC separations are coupled with collision induced dissociation (CID and tandem mass spectrometry (MS/MS. Product ion profiles are often diagnostic for particular regioisomers. The highest sensitivity that can be achieved involves the use of selected reaction monitoring/mass spectrometry (SRM/MS; whereas the highest specificity is obtained with an SRM transitions between an intense parent ion, which contains the intact molecule (M and a structurally significant product ion. This review article provides an overview of arachidonic acid metabolism and targeted chiral methods that have been utilized for the analysis of the structurally diverse eicosanoids that arise.

  2. Chemical fingerprint of Ganmaoling granule by double-wavelength ultra high performance liquid chromatography and ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Lou, Qiong; Ye, Xiaolan; Zhou, Yingyi; Li, Hua; Song, Fenyun

    2015-06-01

    A method incorporating double-wavelength ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry was developed for the investigation of the chemical fingerprint of Ganmaoling granule. The chromatographic separations were performed on an ACQUITY UPLC HSS C18 column (2.1 × 50 mm, 1.8 μm) at 30°C using gradient elution with water/formic acid (1%) and acetonitrile at a flow rate of 0.4 mL/min. A total of 11 chemical constituents of Ganmaoling granule were identified from their molecular weight, UV spectra, tandem mass spectrometry data, and retention behavior by comparing the results with those of the reference standards or literature. And 25 peaks were selected as the common peaks for fingerprint analysis to evaluate the similarities among 25 batches of Ganmaoling granule. The results of principal component analysis and orthogonal projection to latent structures discriminant analysis showed that the important chemical markers that could distinguish the different batches were revealed as 4,5-di-O-caffeoylquinic acid, 3,5-di-O-caffeoylquinic acid, and 4-O-caffeoylquinic acid. This is the first report of the ultra high performance liquid chromatography chemical fingerprint and component identification of Ganmaoling granule, which could lay a foundation for further studies of Ganmaoling granule.

  3. Detection of Gelatin Adulteration in Traditional Chinese Medicine: Analysis of Deer-Horn Glue by Rapid-Resolution Liquid Chromatography-Triple Quadrupole Mass Spectrometry

    OpenAIRE

    Jia Chen; Xian-Long Cheng; Feng Wei; Qian-Qian Zhang; Ming-Hua Li; Shuang-Cheng Ma

    2015-01-01

    Simultaneous identification of donkey-hide gelatin and bovine-hide gelatin in deer-horn glue was established by rapid-resolution liquid chromatography-triple quadrupole mass spectrometry. Water containing 1% NH4HCO3 was used for sample dissolution and trypsin was used for hydrolysis of the gelatins. After separation by a SB-C18 reversed-phase analytical column, collagen marker peptides were detected by mass spectrometry in positive electrospray ionization mode with multiple reaction monitorin...

  4. Characterization of trisiloxane surfactants from agrochemical adjuvants and pollinator-related matrices using liquid chromatography coupled to mass spectrometry.

    Science.gov (United States)

    Chen, Jing; Mullin, Christopher A

    2015-06-01

    Trisiloxane surfactants (TSSs) have been associated with honeybee learning impairment and the ongoing global bee decline. A liquid chromatography-mass spectrometry strategy for the identification of TSSs from agrochemical adjuvants and pollinator-related matrices is introduced here. The strategy incorporates chromatographic retention behavior, isotope ratio, reference to a compiled database of accurate masses, and TSS hydrolysis when necessary. Using this analytical strategy, three TSSs (x = 0, R = H, m = 1, 2, or 3) were identified for the first time from almond flowers of a commercial orchard. The three major purified TSS components in popularly used spray tank adjuvants were identified as TSS (x = 0, m = 0, R = H, CH3, or C(O)CH3) and their structures confirmed by nuclear magnetic resonance spectroscopy. These monitoring tools allow the assessment of the agricultural residues and potential risks of major TSS contaminants to important nontarget species such as honeybee and other essential pollinators. PMID:25654266

  5. Rapid screening for drugs of abuse in biological fluids by ultra high performance liquid chromatography/Orbitrap mass spectrometry.

    Science.gov (United States)

    Jagerdeo, Eshwar; Schaff, Jason E

    2016-08-01

    We present a UPLC(®)-High Resolution Mass Spectrometric method to simultaneously screen for nineteen benzodiazepines, twelve opiates, cocaine and three metabolites, and three "Z-drug" hypnotic sedatives in both blood and urine specimens. Sample processing consists of a high-speed, high-temperature enzymatic hydrolysis for urine samples followed by a rapid supported liquid extraction (SLE). The combination of ultra-high resolution chromatography with high resolution mass spectrometry allows all 38 analytes to be uniquely detected with a ten minute analytical run. Limits of detection for all target analytes are 3ng/mL or better, with only 0.3mL of specimen used for analysis. The combination of low sample volume with fast processing and analysis makes this method a suitable replacement for immunoassay screening of the targeted drug classes, while providing far superior specificity and better limits of detection than can routinely be obtained by immunoassay. PMID:27236533

  6. Identification of monomenthyl succinate, monomenthyl glutarate, and dimenthyl glutarate in nature by high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Hiserodt, Richard D; Adedeji, Jide; John, T V; Dewis, Mark L

    2004-06-01

    Menthol, menthone, and other natural compounds provide a cooling effect and a minty flavor and have found wide application in chewing gum and oral care products. Monomenthyl succinate, monomenthyl glutarate, and dimenthyl glutarate provide a cooling effect without the burning sensation associated with menthol. Additionally, because they do not have a distinct flavor, they can be used in applications other than mint flavors. Because these menthyl esters have not been reported in nature, we undertook to identify a natural source for these cooling compounds. Using high performance liquid chromatography-tandem mass spectrometry, monomenthyl succinate was identified in Lycium barbarum and Mentha piperita, and monomenthyl glutarate and dimenthyl glutarate were identified in Litchi chinesis. The identifications were based on the correlation of mass spectrometric and chromatographic retention time data for the menthyl esters in the extracts with authentic standards which resulted in a 99.980% confidence in the identifications.

  7. [Comparison of the performances of gas chromatography-quadrupole time of flight mass spectrometry and gas chromatography-tandem mass spectrometry in rapid screening and confirmation of 208 pesticide residues in fruits and vegetables].

    Science.gov (United States)

    Cao, Xinyue; Pang, Guofang; Jin, Linghe; Kang, Jian; Hu, Xueyan; Chang, Qiaoying; Wang, Minglin; Fan, Chunlin

    2015-04-01

    The performances of gas chromatography-tandem mass spectrometry (GC-MS/MS) and gas chromatography quadrupole time of flight mass spectrometry (GC-QTOF/MS) for the determination of 208 pesticide residues in fruit and vegetable samples, including apple, orange, tomato and cucumber, were compared comprehensively. Based on the differences of the two instruments, their respective characteristics and scopes of application in the detection of the pesticide residues were presented, which provided the reference for the analysis of pesticide residues. The performance parameters of the two instruments, such as overall recoveries, precisions, limits of detection, linear ranges, identification points and matrix effects, were evaluated according to a designed experiment. At three spiked levels (5.0, 10.0 and 20.0 µg/kg), the average recoveries for the majority of pesticides (93.0%) ranged from 70% to 120% in the four matrices with relative standard deviations below 20%. The limits of detection for most of the pesticides by GC-MS/MS and GC-Q-TOF/MS were less than 5.0 µg/kg. Compared with GC-QTOF/MS, GC-MS/MS showed relatively lower limits of detection and wider linear ranges, and its performance was more satisfactory in accurate quantitative analysis due to its superior sensitivity. On the other hand, GC-QTOF/MS provided accurate mass measurement, which was proved to be an efficient analytical tool on the rapid screening and confirmation of a large number of pesticides and non-target compounds. PMID:26292409

  8. Comprehensive chemical profiling of guizhi fuling capsule by the combined use of gas chromatography-mass spectrometry with a deconvolution software and rapid-resolution liquid chromatography quadrupole time-of-flight tandem mass spectrometry.

    Science.gov (United States)

    Wang, Ya-Qiong; Qi, Lian-Wen; Aa, Jiye; Wang, Guang-Ji; Gao, Wen; Cheng, Shu-Jie; Wang, Zhen-Zhong; Xiao, Wei; Li, Ping

    2012-10-01

    Herbal formulations are complex natural mixtures. Researchers usually tend to focus more on analysis of nonvolatile components but pay less attention to volatile compounds. In this study, an analytical strategy combining two approaches was established for comprehensive analysis of herbal formulations. Guizhi Fuling capsule (GFC), a drug approved by the FDA to enter phase II clinical trial for treatment of primary dysmenorrhea, was taken as a case for analysis. Gas chromatography-mass spectrometry (GC-MS) with automated mass spectral deconvolution and identification system (AMDIS) led to rapid identification of 48 volatile components including four acetophenones, three fatty acid esters, 13 phenylpropanoids and 19 sesquiterpenes. Most of them were found from Guizhi. The volatile oils of Guizhi have been proved to exhibit many pharmacological activities. This is helpful in understanding the pharmacological mechanism of GFC. Furthermore, AMDIS turned out to be efficient and reliable for analysis of complex herbal formulations. Rapid-resolution liquid chromatography (RRLC) coupled with electrospray ionization quadrupole time-of-flight tandem mass spectrometry (ESI-Q-TOF MS/MS) allowed the identification of 70 nonvolatile components including six acetophenones, 12 galloyl glucoses, 31 monoterpene glycosides, three phenols and 12 triterpene acids. Fragmentation behaviors of assigned components, especially triterpene acids, which are hard to identify by low-resolution MS, were first investigated by TOF MS/MS. Characteristic ions and typical loss of assigned triterpene acids were summarized. Combinatorial use of GC-MS-AMDIS and RRLC-ESI-Q-TOF MS/MS could be of great help in global qualitative analysis of GFC, as well as other herbal products. PMID:22297903

  9. Receptor-based high-throughput screening and identification of estrogens in dietary supplements using bioaffinity liquid-chromatography ion mobility mass spectrometry

    NARCIS (Netherlands)

    Aqai, P.; Gómez Blesa, N.; Major, H.; Pedotti, P.; Varani, L.; Ferrero, V.E.V.; Haasnoot, W.; Nielen, M.W.F.

    2013-01-01

    A high-throughput bioaffinity liquid chromatography-mass spectrometry (BioMS) approach was developed and applied for the screening and identification of recombinant human estrogen receptor a (ERa) ligands in dietary supplements. For screening, a semi-automated mass spectrometric ligand binding assay

  10. Qualitative aspects in the analysis of pesticide residues in fruits and vegetables using fast, low-pressure gas chromatography - time-of-flight mass spectrometry

    Science.gov (United States)

    Assessment of qualitative results in analytical methods is needed to estimate selectivity and devise criteria for chemical identification, particularly for mass spectrometric analysis. Low-pressure gas chromatography - mass spectrometry (LP-GC/MS) has been demonstrated to increase the speed of anal...

  11. Development of a method for quantitation of retinol and retinyl palmitate in human serum using high-performance liquid chromatography atmospheric pressure chemical ionization mass spectrometry.

    NARCIS (Netherlands)

    Breemen, van R.B.; Nikolic, D.; Xu, X.Y.; Xiong, Y.S.; Lieshout, van M.; West, C.E.; Schilling, A.B.

    1998-01-01

    A method for the quantitative analysis of the vitamin A compounds all-trans-retinol and all-trans-retinyl palmitate was developed using high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (APCI-LC-MS). Unlike previous quantitative mass spectrometric meth

  12. Quantitative Analysis and Fingerprint Profiles for Quality Control of Fructus Schisandrae by Gas Chromatography: Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Yong-Gang Xia

    2014-01-01

    Full Text Available This paper describes a simple, rapid, and effective quality assessment method for Fructus Schisandrae by gas chromatography-mass spectrum (GC-MS. The method was established by using specific lignan fingerprint profiles and quantitation of characteristic compounds in this herbal medicine. The GC-MS fingerprints of 15 batches of Schisandra samples from different regions of China showed similar lignan profiles. Five peaks were selected as characteristic peaks, and all of these were identified by using GC-MS techniques. The relative retention times of these characteristic peaks in the GC-MS fingerprint were established as an important parameter for identification of Schisandra samples. Meanwhile, relative peak areas may be a feasible approach to discriminate the S. chinensis and S. sphenanthera. Finally, these pharmacologically active constituents in the titled plant, schisandrins A–C and schizandrols A and B, were quantitatively determined using a validated GC-MS method.

  13. Broad-spectrum drug screening of meconium by liquid chromatography with tandem mass spectrometry and time-of-flight mass spectrometry.

    Science.gov (United States)

    Ristimaa, Johanna; Gergov, Merja; Pelander, Anna; Halmesmäki, Erja; Ojanperä, Ilkka

    2010-09-01

    Analysis of the major drugs of abuse in meconium has been established in clinical practice for detecting fetal exposure to illicit drugs, particularly for the ready availability of the sample and ease of collection from diapers, compared with neonatal hair and urine. Very little is known about the occurrence and detection possibilities of therapeutic and licit drugs in meconium. Meconium specimens (n = 209) were collected in delivery hospitals, from infants of mothers who were suspected to be drug abusers. A targeted analysis method by liquid chromatography-triple quadrupole mass spectrometry (LC-MS/MS) was developed for abused drugs: amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine, morphine, codeine, 6-monoacetylmorphine, oxycodone, methadone, tramadol, buprenorphine, and norbuprenorphine. A separate LC-MS/MS method was developed for 11-nor-∆(9)-tetrahydrocannabinol-9-carboxylic acid. A screening method based on LC coupled to time-of-flight MS was applied to a broad spectrum of drugs. As a result, a total of 77 different compounds were found. The main drug findings in meconium were as follows: local anesthetics 82.5% (n = 172), nicotine or its metabolites 61.5% (n = 129), opioids 48.5% (n = 101), stimulants 21.0% (n = 44), hypnotics and sedatives 19.0% (n = 40), antidepressants 18.0% (n = 38), antipsychotics 5.5% (n = 11), and cannabis 3.0% (n = 5). By revealing drugs and metabolites beyond the ordinary scope, the present procedure helps the pediatrician in cases where maternal denial is strong but the infant seems to suffer from typical drug-withdrawal symptoms. Intrapartum drug administration cannot be differentiated from gestational drug use by meconium analysis, which affects the interpretation of oxycodone, tramadol, fentanyl, pethidine, and ephedrine findings. PMID:20617307

  14. Impact of Pharmaceutical Impurities in Ecstasy Tablets: Gas Chromatography-Mass Spectrometry Study.

    Science.gov (United States)

    Jalali, Amir; Hatamie, Amir; Saferpour, Tahere; Khajeamiri, Alireza; Safa, Tahere; Buazar, Foad

    2016-01-01

    In this study, a simple and reliable method by gas chromatograph-mass spectrometry (GC-MS) was developed for the fast and regular identification of 3, 4-MDMA impurities in ecstasy tablets. In so doing, 8 samples of impurities were extracted by diethyl ether under alkaline condition and then analyzed by GC-MS. The results revealed high MDMA levels ranging from 37.6% to 57.7%. The GC-MS method showed that unambiguous identification can be achieved for MDMA from 3, 4-methylenedioxyamphetamine (MDA), Amphetamine (AM), methamphetamine (MA) and ketamine (Keta) compounds, respectively. The experimental results indicated the acceptable time window without interfering peaks. It is found that GC-MS was provided a suitable and rapid identification approach for MDMA (Ecstacy) tablets, particularly in the Forensic labs. Consequently, the intense MDMA levels would support the police to develop a simple quantification of impurity in Ecstasy tablets. PMID:27610162

  15. Liquid chromatography coupled with time-of-flight and ion trap mass spectrometry for qualitative analysis of herbal medicines

    Institute of Scientific and Technical Information of China (English)

    Xiao-Fei Chen; Hai-Tang Wu; Guang-Guo Tan; Zhen-Yu Zhu; Yi-Feng Chai

    2011-01-01

    With the expansion of herbal medicine (HM) market, the issue on how to apply up-to- date analytical tools on qualitative analysis of HMs to assure their quality, safety and efficacy has been arousing great attention. Due to its inherent characteristics of accurate mass measurements and multiple stages analysis, the integrated strategy of liquid chromatography (LC) coupled with time-of-flight mass spectrometry (TOF-MS) and ion trap mass spectrometry (IT-MS) is well-suited to be performed as qualitative analysis tool in this field. The purpose of this review is to provide an overview on the potential of this integrated strategy, including the review of general features of LC-IT-MS and LC-TOF-MS, the advantages of their combination, the common procedures for structure elucidation, the potential of LC-hybrid-IT-TOF/MS and also the summary and discussion of the applications of the integrated strategy for HM qualitative analysis (2006-2011). The advantages and future developments of LC coupled with IT and TOF-MS are highlighted.

  16. Qualitative and quantitative two-dimensional thin-layer chromatography/high performance liquid chromatography/diode-array/electrospray-ionization-time-of-flight mass spectrometry of cholinesterase inhibitors.

    Science.gov (United States)

    Mroczek, Tomasz

    2016-09-10

    Recently launched thin-layer chromatography-mass spectrometry (TLC-MS) interface enabling extraction of compounds directly from TLC plates into MS ion source was unusually extended into two-dimensional thin-layer chromatography/high performance liquid chromatography (2D, TLC/HPLC) system by its a direct connection to a rapid resolution 50×2.1mm, I.D. C18 column compartment followed by detection by diode array (DAD) and electrospray ionisation time-of-flight mass spectrometry (ESI-TOF-MS). In this way, even not separated bands of complicated mixtures of natural compounds could be analysed structurally, only within 1-2min after development of TLC plates. In comparison to typically applied TLC-MS interface, no ion suppression for acidic mobile phases was observed. Also, substantial increase in ESI-TOF-MS sensitivities and quality of spectra, were noticed. It has been utilised in combination with TLC- based bioautographic approaches of acetylcholinesterase (AChE) inhibitors, However, it can be also applied in any other procedures related to bioactivity (e.g. 2,2-Diphenyl-1-picryl-hydrazyl-DPPH screen test for radicals). This system has been also used for determination of half maximal inhibitory concentration (IC50 values) of the active inhibitor-galanthamine, as an example. Moreover, AChE inhibitory potencies of some of purified plant extracts, never studied before, have been quantitatively measured. This is first report of usage such the 2D TLC/HPLC/MS system both for qualitative and quantitative evaluation of cholinesterase inhibitors in biological matrices.

  17. Determination of mepitiostane metabolites in human urine by liquid chromatography/tandem mass spectrometry for sports drug testing.

    Science.gov (United States)

    Okano, Masato; Sato, Mitsuhiko; Kojima, Asami; Kageyama, Shinji

    2015-11-10

    Mepitiostane (2α,3α-epithio-17β-(1-methoxycyclopentyloxy)-5α-androstane), which is a prodrug of epitiostanol (2α,3α-epitio-5α-androstane-17β-ol), is an epitiosteroid having anti-estrogenic and weak androgenic anabolic activities. The World Anti-Doping Agency prohibits the misuse of mepitiostane by athletes. Detection of the urinary metabolites epitiostanol sulfoxide and epitiostanol was studied using liquid chromatography/mass spectrometry (LC-MS) for doping control purposes. The use of LC-MS provided advantages over gas chromatography/mass spectrometry for detecting heat labile steroids because epitiostanol and epitiostanol sulfoxide were primarily pyrolized to 5α-androst-2-en-17β-ol. The method consists of enzymatic hydrolysis using β-glucuronidase (Escherichia coli), liquid-liquid extraction, and subsequent ultra-performance liquid chromatography/electrospray-tandem mass spectrometry. Epitiostanol sulfoxide was determined at urinary concentrations of 0.5-50ng/mL, recovery was 76.2-96.9%, and assay precision was calculated as 0.9-1.7% (intra-day) and 2.0-6.6% (inter-day). Epitiostanol was determined at urinary concentrations of 0.5-50ng/mL, recovery was 26.1-35.6% and assay precision was calculated as 4.1-4.6% (intra-day) and 3.3-8.5% (inter-day). The limits of detection for epitiostanol sulfoxide and epitiostanol were 0.05ng/mL and 0.10ng/mL, respectively. Epitiostanol sulfoxide and epitiostanol, as their gluco-conjugates, were identified in human urine after oral administration of 10mg mepitiostane. Epitiostanol sulfoxide and epitiostanol could be detected up to 48h and 24h after administration, respectively. The results showed that the detection window of epitiostanol is much shorter than that of epitiostanol sulfoxide. The LC-MS detection of urinary epitiostanol sulfoxide, a specific metabolite with a sulphur atom in its molecular structure, is likely to be able to identify the abuse of mepitiostane.

  18. SFC-APLI-(TOF)MS: Hyphenation of Supercritical Fluid Chromatography to Atmospheric Pressure Laser Ionization Mass Spectrometry.

    Science.gov (United States)

    Klink, Dennis; Schmitz, Oliver Johannes

    2016-01-01

    Atmospheric-pressure laser ionization mass spectrometry (APLI-MS) is a powerful method for the analysis of polycyclic aromatic hydrocarbon (PAH) molecules, which are ionized in a selective and highly sensitive way via resonance-enhanced multiphoton ionization. APLI was presented in 2005 and has been hyphenated successfully to chromatographic separation techniques like high performance liquid chromatography (HPLC) and gas chromatography (GC). In order to expand the portfolio of chromatographic couplings to APLI, a new hyphenation setup of APLI and supercritical-fluid chromatography (SFC) was constructed and aim of this work. Here, we demonstrate the first hyphenation of SFC and APLI in a simple designed way with respect to different optimization steps to ensure a sensitive analysis. The new setup permits qualitative and quantitative determination of native and also more polar PAH molecules. As a result of the altered ambient characteristics within the source enclosure, the quantification of 1-hydroxypyrene (1-HP) in human urine is possible without prior derivatization. The limit of detection for 1-HP by SFC-APLI-TOF(MS) was found to be 0.5 μg L(-1), which is lower than the 1-HP concentrations found in exposed persons. PMID:26633261

  19. Quantitative analysis of arbutin and hydroquinone in strawberry tree (Arbutus unedo L., Ericaceae) leaves by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Jurica, Karlo; Karačonji, Irena Brčić; Šegan, Sandra; Opsenica, Dušanka Milojković; Kremer, Dario

    2015-09-01

    The phenolic glycoside arbutin and its metabolite with uroantiseptic activity hydroquinone occur naturally in the leaves of various medicinal plants and spices. In this study, an extraction procedure coupled with gas chromatography-mass spectrometry (GC-MS) was developed to determine arbutin and hydroquinone content in strawberry tree (Arbutus unedo L., Ericaceae) leaves. The method showed good linearity (R2>0.9987) in the tested concentration range (0.5-200 μg mL(-1)), as well as good precision (RSDarbutin and hydroquinone, respectively). The results obtained by the validated GC-MS method corresponded well to those obtained by high performance liquid chromatography (HPLC) method. The proposed method was then applied for determining arbutin and hydroquinone content in methanolic leaf extracts. The amount of arbutin in the leaves collected on the island of Koločep (6.82 mg g(-1) dry weight) was found to be higher (tpaired=43.57, tc=2.92) in comparison to the amount of arbutin in the leaves collected on the island of Mali Lošinj (2.75 mg g(-1) dry weight). Hydroquinone was not detected in any of the samples. The analytical features of the proposed GC-MS method demonstrated that arbutin and hydroquinone could be determined alternatively by gas chromatography. Due to its wide concentration range, the method could also be suitable for arbutin and hydroquinone analysis in leaves of other plant families (Rosaceae, Lamiaceae, etc.). PMID:26444340

  20. Qualitative and Quantitative Analysis of Major Triterpenoids in Alismatis Rhizoma by High Performance Liquid Chromatography/Diode-Array Detector/Quadrupole-Time-of-Flight Mass Spectrometry and Ultra-Performance Liquid Chromatography/Triple Quadrupole Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Wanli Zhao

    2015-07-01

    Full Text Available Alismatis Rhizoma (AMR is a well-known natural medicine with a long history in Chinese medicine and has been commonly used for treating a wide range of ailments related to dysuria, edema, nephropathy, hyperlipidaemia, diabetes, inflammation as well as tumors in clinical applications. Most beneficial effects of AMR are attributed to the presence of protostane terpenoids, the major active ingredients of Alismatis Rhizoma (AMR. In this study, a systematic high performance liquid chromatography/diode-array detector/quadrupole-time-of-flight mass spectrometry (HPLC-DAD-Q-TOF MS and ultra-performance liquid chromatography/triple quadrupole mass spectrometry (UPLC-QqQ MS method was developed for qualitative and quantitative analyses of the major AMR triterpenoids. First, a total of 25 triterpenoid components, including 24 known compounds and one new compound were identified by comparison with UV spectra, molecular ions and fragmentation behaviors of reference standards or the literature. Second, an efficient method was established for the rapid simultaneous determination of 14 representative triterpenoids by UPLC-QqQ MS. Forty-three batches of AMR were analyzed with linearity (r, 0.9980–0.9999, intra-day precision (RSD, 1.18%–3.79%, inter-day precision (RSD, 1.53%–3.96%, stability (RSD, 1.32%–3.97%, repeatability (RSD, 2.21%–4.25%, and recovery (98.11%–103.8%. These results indicated that new approaches combining HPLC-DAD-Q-TOF MS and UPLC-QqQ MS are applicable in the qualitative and quantitative analysis of AMR.

  1. [Non-target screening of organic pollutants in sediments and sludges using gas chromatography-mass spectrometry and automated mass spectral deconvolution].

    Science.gov (United States)

    Wang, Gang; Ma, Huilian; Wang, Longxing; Chen, Jiping; Hou, Xiaohong

    2015-12-01

    A screening method in the combination of ultrasonic extraction, gas chromatography-mass spectrometry detection and automated mass spectrometry deconvolution technique was developed for non-target screening of non-polar and weak polar pollutants in sediments and sludges. The samples were extracted by ultrasonication for 20 min using dichloromethane for three times. The extraction solutions were cleaned-up by gel permeation chromatography and a silica gel column, and then 3 g of copper powder was used to remove the sulfur by ultrasonication for 10 min. Parallel experiments were carried out for 5 times and the RSDs were ranged from 5.8% to 14.9%. Automated mass spectral deconvolution & identification system (AMDIS) would improve the resolution of overlapping peaks, and identify the pure mass spectrum of the analytes in the cases of stronger background interference and co-extracted substances covering. Standard spectrum databases, such as NISTDRUG, NISTEPA, NISTFDA, Mass Spectral Library, etc, would qualitatively identify the organic pollutants in the samples. As a result, a total of 290 organic pollutants were identified, of which 190 and 153 pollutants were found in sediments and sludges, respectively. The identified pollutants included the Environmental Protection Agency (EPA) priority pollutants, pharmaceuticals, herbicides, antioxidants, intermediates, organic solvents and chemical raw materials. The proposed method is proved to be a promising one for non-target screening of complex matrix samples with the advantages of higher sensitivity and better repeatability. PMID:27097463

  2. [Non-target screening of organic pollutants in sediments and sludges using gas chromatography-mass spectrometry and automated mass spectral deconvolution].

    Science.gov (United States)

    Wang, Gang; Ma, Huilian; Wang, Longxing; Chen, Jiping; Hou, Xiaohong

    2015-12-01

    A screening method in the combination of ultrasonic extraction, gas chromatography-mass spectrometry detection and automated mass spectrometry deconvolution technique was developed for non-target screening of non-polar and weak polar pollutants in sediments and sludges. The samples were extracted by ultrasonication for 20 min using dichloromethane for three times. The extraction solutions were cleaned-up by gel permeation chromatography and a silica gel column, and then 3 g of copper powder was used to remove the sulfur by ultrasonication for 10 min. Parallel experiments were carried out for 5 times and the RSDs were ranged from 5.8% to 14.9%. Automated mass spectral deconvolution & identification system (AMDIS) would improve the resolution of overlapping peaks, and identify the pure mass spectrum of the analytes in the cases of stronger background interference and co-extracted substances covering. Standard spectrum databases, such as NISTDRUG, NISTEPA, NISTFDA, Mass Spectral Library, etc, would qualitatively identify the organic pollutants in the samples. As a result, a total of 290 organic pollutants were identified, of which 190 and 153 pollutants were found in sediments and sludges, respectively. The identified pollutants included the Environmental Protection Agency (EPA) priority pollutants, pharmaceuticals, herbicides, antioxidants, intermediates, organic solvents and chemical raw materials. The proposed method is proved to be a promising one for non-target screening of complex matrix samples with the advantages of higher sensitivity and better repeatability.

  3. Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry.

    Science.gov (United States)

    Miyaguchi, Hajime

    2016-09-20

    An improved version of a polymerase chain reaction (PCR)-restriction fragment length polymorphism (RFLP) method for genotyping toxic pufferfish species by liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) is described. DNA extraction is carried out using a silica membrane-based DNA extraction kit. After the PCR amplification using a detergent-free PCR buffer, restriction enzymes are added to the solution without purifying the reaction solution. A reverse-phase silica monolith column and a Fourier transform high resolution mass spectrometer having a modified Kingdon trap analyzer are employed for separation and detection, respectively. The mobile phase, consisting of 400 mM 1,1,1,3,3,3-hexafluoro-2-propanol, 15 mM triethylamine (pH 7.9) and methanol, is delivered at a flow rate of 0.4 ml/min. The cycle time for LC/ESI-MS analysis is 8 min including equilibration of the column. Deconvolution software having an isotope distribution model of the oligonucleotide is used to calculate the corresponding monoisotopic mass from the mass spectrum. For analysis of oligonucleotides (range 26-79 nucleotides), mass accuracy was 0.62 ± 0.74 ppm (n = 280) and excellent accuracy and precision were sustained for 180 hr without use of a lock mass standard.

  4. Accurate screening for synthetic preservatives in beverage using high performance liquid chromatography with time-of-flight mass spectrometry.

    Science.gov (United States)

    Li, Xiu Qin; Zhang, Feng; Sun, Yan Yan; Yong, Wei; Chu, Xiao Gang; Fang, Yan Yan; Zweigenbaum, Jerry

    2008-02-11

    In this study, liquid chromatography time-of-flight mass spectrometry (HPLC/TOF-MS) is applied to qualitation and quantitation of 18 synthetic preservatives in beverage. The identification by HPLC/TOF-MS is accomplished with the accurate mass (the subsequent generated empirical formula) of the protonated molecules [M+H]+ or the deprotonated molecules [M-H]-, along with the accurate mass of their main fragment ions. In order to obtain sufficient sensitivity for quantitation purposes (using the protonated or deprotonated molecule) and additional qualitative mass spectrum information provided by the fragments ions, segment program of fragmentor voltages is designed in positive and negative ion mode, respectively. Accurate mass measurements are highly useful in the complex sample analyses since they allow us to achieve a high degree of specificity, often needed when other interferents are present in the matrix. The mass accuracy typically obtained is routinely better than 3 ppm. The 18 compounds behave linearly in the 0.005-5.0mg.kg(-1) concentration range, with correlation coefficient >0.996. The recoveries at the tested concentrations of 1.0mg.kg(-1)-100mg.kg(-1) are 81-106%, with coefficients of variation preservatives in foodstuff. The method is suitable for routine quantitative and qualitative analyses of synthetic preservatives in foodstuff.

  5. Accurate screening for synthetic preservatives in beverage using high performance liquid chromatography with time-of-flight mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Li Xiuqin; Zhang Feng; Sun Yanyan; Yong Wei [Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Jia 3, Gaobeidian North Road, Beijing 100025 (China); Chu Xiaogang [Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Jia 3, Gaobeidian North Road, Beijing 100025 (China)], E-mail: lixq_sypu@yahoo.com; Fang Yanyan; Zweigenbaum, Jerry [Agilent Technologies, Inc., 2850 Centerville Road, Wilmington, Delaware (United States)

    2008-02-11

    In this study, liquid chromatography time-of-flight mass spectrometry (HPLC/TOF-MS) is applied to qualitation and quantitation of 18 synthetic preservatives in beverage. The identification by HPLC/TOF-MS is accomplished with the accurate mass (the subsequent generated empirical formula) of the protonated molecules [M + H]+ or the deprotonated molecules [M - H]-, along with the accurate mass of their main fragment ions. In order to obtain sufficient sensitivity for quantitation purposes (using the protonated or deprotonated molecule) and additional qualitative mass spectrum information provided by the fragments ions, segment program of fragmentor voltages is designed in positive and negative ion mode, respectively. Accurate mass measurements are highly useful in the complex sample analyses since they allow us to achieve a high degree of specificity, often needed when other interferents are present in the matrix. The mass accuracy typically obtained is routinely better than 3 ppm. The 18 compounds behave linearly in the 0.005-5.0 mg.kg{sup -1} concentration range, with correlation coefficient >0.996. The recoveries at the tested concentrations of 1.0 mg.kg{sup -1}-100 mg.kg{sup -1} are 81-106%, with coefficients of variation <7.5%. Limits of detection (LODs) range from 0.0005 to 0.05 mg.kg{sup -1}, which are far below the required maximum residue level (MRL) for these preservatives in foodstuff. The method is suitable for routine quantitative and qualitative analyses of synthetic preservatives in foodstuff.

  6. Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry.

    Science.gov (United States)

    Miyaguchi, Hajime

    2016-01-01

    An improved version of a polymerase chain reaction (PCR)-restriction fragment length polymorphism (RFLP) method for genotyping toxic pufferfish species by liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) is described. DNA extraction is carried out using a silica membrane-based DNA extraction kit. After the PCR amplification using a detergent-free PCR buffer, restriction enzymes are added to the solution without purifying the reaction solution. A reverse-phase silica monolith column and a Fourier transform high resolution mass spectrometer having a modified Kingdon trap analyzer are employed for separation and detection, respectively. The mobile phase, consisting of 400 mM 1,1,1,3,3,3-hexafluoro-2-propanol, 15 mM triethylamine (pH 7.9) and methanol, is delivered at a flow rate of 0.4 ml/min. The cycle time for LC/ESI-MS analysis is 8 min including equilibration of the column. Deconvolution software having an isotope distribution model of the oligonucleotide is used to calculate the corresponding monoisotopic mass from the mass spectrum. For analysis of oligonucleotides (range 26-79 nucleotides), mass accuracy was 0.62 ± 0.74 ppm (n = 280) and excellent accuracy and precision were sustained for 180 hr without use of a lock mass standard. PMID:27684516

  7. Determination of the rodenticide difenacoum in biological materials by high-pressure liquid chromatography with confirmation of identity by mass spectrometry.

    Science.gov (United States)

    Mundy, D E; Machin, A F

    1977-09-21

    A method for determining difenacoum in liver, plasma, urine and feedingstuffs by high-pressure liquid chromatography is described. Samples are cleaned up by molecular exclusion chromatography on porous glass. In some cases this also serves for determination; if not, the separated difenacoum is determined on an adsorption column. Identity is confirmed by chemical ionisation mass spectrometry. Recoveries at levels of 0.025-5 ppm from plasma were 101-113% by exclusion chromatography alone and 93-101% after adsorption chromatography. Recoveries from liver after both chromatographic steps were 62-86%. Reasons for the lower recoveries from liver are suggested. PMID:893620

  8. Sensitive quantification of omeprazole and its metabolites in human plasma by liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Hofmann, Ute; Schwab, Matthias; Treiber, Gerd; Klotz, Ulrich

    2006-02-01

    A sensitive method was developed for the simultaneous determination of omeprazole and its major metabolites 5-hydroxyomeprazole and omeprazole sulfone in human plasma by HPLC-electrospray mass spectrometry. Following liquid-liquid extraction HPLC separation was achieved on a ProntoSil AQ, C18 column using a gradient with 10 mM ammonium acetate in water (pH 7.25) and acetonitrile. The mass spectrometer was operated in the selected ion monitoring mode using the respective MH(+) ions, m/z 346 for omeprazole, m/z 362 for 5-hydroxy-omeprazole and omeprazol-sulfone and m/z 300 for the internal standard (2-{[(3,5-dimethylpyridine-2-yl)methyl]thio}-1H-benzimidazole-5-yl)methanol. The limit of quantification (LOQ) achieved with this method was 5 ng/ml for 5-hydroxyomeprazole and 10 ng/ml for omeprazole and omeprazole-sulfone using 0.25 ml of plasma. Intra- and inter-assay variability was below 11% over the whole concentration range from 5 to 250 ng/ml for 5-hydroxyomeprazol and from 10 to 750 ng/ml for omeprazole and omeprazole-sulfone. The method was successfully applied to the determination of pharmacokinetic parameters of esomeprazole and the two major metabolites after a single dose and under steady state conditions. PMID:16338182

  9. Liquid Chromatography Mass Spectrometry-Based Proteomics: Biological and Technological Aspects

    Energy Technology Data Exchange (ETDEWEB)

    Karpievitch, Yuliya V.; Polpitiya, Ashoka D.; Anderson, Gordon A.; Smith, Richard D.; Dabney, Alan R.

    2010-12-01

    Mass spectrometry-based proteomics has become the tool of choice for identifying and quantifying the proteome of an organism. Though recent years have seen a tremendous improvement in instrument performance and the computational tools used, significant challenges remain, and there are many opportunities for statisticians to make important contributions. In the most widely used "bottom-up" approach to proteomics, complex mixtures of proteins are first subjected to enzymatic cleavage, the resulting peptide products are separated based on chemical or physical properties and analyzed using a mass spectrometer. The two fundamental challenges in the analysis of bottom-up MS-based proteomics are: (1) Identifying the proteins that are present in a sample, and (2) Quantifying the abundance levels of the identified proteins. Both of these challenges require knowledge of the biological and technological context that gives rise to observed data, as well as the application of sound statistical principles for estimation and inference. We present an overview of bottom-up proteomics and outline the key statistical issues that arise in protein identification and quantification.

  10. Detection of 10 sweeteners in various foods by liquid chromatography/tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Chui-Shiang Chang

    2014-09-01

    Full Text Available The analytical method for sweeteners in various food matrixes is very important for food quality control and regulation enforcement. A simple and rapid method for the simultaneous determination of 10 sweeteners [acesulfame potassium (ACS-K, aspartame (ASP, cyclamate (CYC, dulcin (DUL, glycyrrhizic acid (GA, neotame (NEO, neohesperidin dihydrochalcone (NHDC, saccharin (SAC, sucralose (SCL, and stevioside (STV] in various foods by liquid chromatography/tandem mass chromatography (LC–MS/MS was developed. The chromatographic separation was performed on a Phenomenex Luna Phenyl-Hexyl (5 μm, 4.6 mm × 150 mm column with gradient elution of 10 mM ammonium acetate in water and 10 mM ammonium acetate in methanol. The recoveries of the 10 sweeteners were between 75% and 120%, and the coefficients of variation were less than 20%. The limits of quantification were 0.5 μg/kg for NHDC and SCL. For the other sweeteners, the limits of quantification were 0.1 μg/kg. Compared to the traditional high-performance liquid chromatography method, the LC–MS/MS method could provide better sensitivity, higher throughput, enhanced specificity, and more sweeteners analyzed in a single run. The samples included 27 beverages (16 alcoholic and 11 nonalcoholic beverages and 15 pickled foods (1 pickled pepper, 3 candies, and 11 candied fruits. Two remanufactured wines were found to contain 7.2, 8.5 μg/g SAC and 126.5, 123 μg/g CYC, respectively. ACS-K, ASP, SCL, and NEO were detected in five beverages and drinks. The pickled peppers and candied fruits were found to contain SAC, GA, CYC, ASP, STV, NEO, and ACS-K. The wine with sweeteners detected was remanufactured wine, not naturally fermented wine. Therefore, the ingredient label for the sweeteners of remanufactured wine should be regulated by the proper authority for inspection of sweeteners.

  11. [THE DIAGNOSTICS OF HEREDITARY DISORDERS OF METABOLISM OF PURINES AND PYRIMIDINES IN CHILDREN USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY OF ELECTRO-SPRAY TANDEM MASS-SPECTROMETRY].

    Science.gov (United States)

    Mamedov, I S; Zolkina, I V; Sukhorukov, V S

    2015-06-01

    The article presents data concerning new technique of diagnostic of diseases of metabolism of purines and pyrimidines using high performance liquid chromatography combined with electro-spray mass-spectrometry. The procedure of analysis is described in detail: from pre-analytical stage to interpretation of data of liquid chromatography mass-spectrometry, control of quality of data analysis, mass-spectrometry parameters and chromatographic conditions of analysis of purines, pyrimidines and their metabolites. The reference values are presented for purine and pyrimidine nucleosides and bases in urine of healthy individuals. The chemical structure of purines, pyrimidines and their metabolites and examples of chromato-mass-spectrograms under various hereditary disorders of metabolism of purines and pyrimidines are presented as well. The article is targeted to pediatricians of all profiles, medical geneticists and physicians of laboratory diagnostic. PMID:26466447

  12. Cobalamin speciation using reversed-phase micro-high-performance liquid chromatography interfaced to inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Micro-high-performance liquid chromatography interfaced to inductively coupled plasma mass spectrometry was optimized for the determination and separation of a mixture of cobalt containing species. Four cobalamin species (cyanocobalamin, hydroxocobalamin, methylcobalamin, and 5'-deoxyadenosylcobalamin) representing the various forms of vitamin B12 as well as the harmful corrinoid analogue cobinamide dicyanide were separated using reversed-phase microcapillary chromatography with columns containing C18 packing material with a 2-μm particle size. Selection of organic solvents for the separation took into consideration compatibility with the inductively coupled plasma mass spectrometer being used for element specific detection. Optimized method conditions included use of a methanol gradient and make-up solution for the nebulizer. Some issues associated with dead volume were overcome by the extension of the gradient program. The total analysis time was 52 min. The column-to-column variability was evaluated and was found to be very reasonable (9% RSD on average), confirming that this method is rugged and that the technology should be easily transferred to other laboratories

  13. Determination of pesticides and veterinary drug residues in food by liquid chromatography-mass spectrometry: A review.

    Science.gov (United States)

    Masiá, Ana; Suarez-Varela, Maria Morales; Llopis-Gonzalez, Agustin; Picó, Yolanda

    2016-09-14

    Monitoring of pesticides and veterinary drug residues is required to enforce legislation and guarantee food safety. Liquid chromatography-mass spectrometry (LC-MS) is the prevailing technique for assessing both types of residues because LC offers a versatile and universal separation mechanism suitable for non-gas chromatography (GC) amenable and the majority of GC-amenable compounds. This characteristic becomes more relevant when LC is coupled to MS because the high sensitivity and specificity of the detector allows to apply generic sample preparation procedures, which simultaneously extract a wide variety of residues with different physico-chemical properties. Determination of metabolites and degradation products, non-target suspected screening of an increasing number of residues, and even unknowns identification are also becoming inherent LC-MS advantages thanks to the latest advances. For routine analysis and, in particular, for official surveillance purposes in food control, analytical methods properly validated following strict guidelines are needed. After a brief introduction and an outline of the legislation applicable around the world, aspects such as improvement of specificity of high-throughput methods, resolution and mass accuracy of identification strategies and quantitative accuracy are critically reviewed in this article. In them, extraction, separation and determination are emphasized. The main objective is to offer an assessment of the state of the art and identify research needs and future trends in determining pesticide and veterinary drug residues in food by LC-MS. PMID:27566339

  14. Quantitative determination of acetylcholine in microdialysis samples using liquid chromatography/atmospheric pressure spray ionization mass spectrometry.

    Science.gov (United States)

    Keski-Rahkonen, Pekka; Lehtonen, Marko; Ihalainen, Jouni; Sarajärvi, Timo; Auriola, Seppo

    2007-01-01

    A fast, simple and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the determination of acetylcholine in rat brain microdialysis samples. The chromatographic separation was achieved in 3 min on a reversed-phase column with isocratic conditions using a mobile phase containing 2% (v/v) of acetonitrile and 0.05% (v/v) of trifluoroacetic acid (TFA). A stable isotope-labeled internal standard was included in the analysis and detection was carried out with a linear ion trap mass spectrometer using selected reaction monitoring (SRM). Analyte ionization was performed with an atmospheric pressure chemical ionization (APCI) source without applying discharge current (atmospheric pressure spray ionization). This special ionization technique offered significant advantages over electrospray ionization for the analysis of acetylcholine with reversed-phase ion-pairing chromatography. The lower limit of quantification was 0.15 nM (1.5 fmol on-column) and linearity was maintained over the range of 0.15-73 nM, providing a concentration range that is significantly wider than that of the existing LC/MS methods. Good accuracy and precision were obtained for concentrations within the standard curve range. The method was validated and has been used extensively for the determination of acetylcholine in rat brain microdialysis samples.

  15. Determination of pesticides and veterinary drug residues in food by liquid chromatography-mass spectrometry: A review.

    Science.gov (United States)

    Masiá, Ana; Suarez-Varela, Maria Morales; Llopis-Gonzalez, Agustin; Picó, Yolanda

    2016-09-14

    Monitoring of pesticides and veterinary drug residues is required to enforce legislation and guarantee food safety. Liquid chromatography-mass spectrometry (LC-MS) is the prevailing technique for assessing both types of residues because LC offers a versatile and universal separation mechanism suitable for non-gas chromatography (GC) amenable and the majority of GC-amenable compounds. This characteristic becomes more relevant when LC is coupled to MS because the high sensitivity and specificity of the detector allows to apply generic sample preparation procedures, which simultaneously extract a wide variety of residues with different physico-chemical properties. Determination of metabolites and degradation products, non-target suspected screening of an increasing number of residues, and even unknowns identification are also becoming inherent LC-MS advantages thanks to the latest advances. For routine analysis and, in particular, for official surveillance purposes in food control, analytical methods properly validated following strict guidelines are needed. After a brief introduction and an outline of the legislation applicable around the world, aspects such as improvement of specificity of high-throughput methods, resolution and mass accuracy of identification strategies and quantitative accuracy are critically reviewed in this article. In them, extraction, separation and determination are emphasized. The main objective is to offer an assessment of the state of the art and identify research needs and future trends in determining pesticide and veterinary drug residues in food by LC-MS.

  16. A metabonomic analysis of serum from rats treated with ricinine using ultra performance liquid chromatography coupled with mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Jing Peng

    Full Text Available A metabonomic approach based on ultra performance liquid chromatography coupled with mass spectrometry (UPLC/MS was used to study the hepatotoxicity of ricinine in rats. Potential biomarkers of ricinine toxicity and toxicological mechanism were analyzed by serum metabonomic method. The significant differences in the metabolic profiling of the control and treated rats were clear by using the principal components analysis (PCA of the chromatographic data. Significant changes of metabolite biomarkers like phenylalanine, tryptophan, cholic acid, LPC and PC were detected in the serum. These biochemical changes were related to the metabolic disorders in amino acids and phospholipids. This research indicates that UPLC/MS-based metabonomic analysis of serum samples can be used to predict the hepatotoxicity and further understand the toxicological mechanism induced by ricinine. This work shows that metabonomics method is a valuable tool in drug mechanism study.

  17. In vivo and in vitro metabolism of aspirin eugenol ester in dog by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Shen, Youming; Liu, Xiwang; Yang, Yajun; Li, Jianyong; Ma, Ning; Li, Bing

    2015-01-01

    Aspirin eugenol ester (AEE) is a promising drug candidate for treatment of inflammation, pain and fever and prevention of cardiovascular diseases with fewer side effects than its precursor, aspirin. Investigation into its metabolic process in target animal species will help to illustrate its mechanism of action and to establish its residual mark compound to formulate its dosage. Six beagle dogs were orally given a dose of 20 mg kg(-1) of AEE and one dog was used to prepare blank liver microsomes. Their liver microsomes were prepared for in vitro study and their plasma and urine were collected for in vivo metabolic analysis using liquid chromatography tandem mass spectrometry. In this study we identified 10 metabolites, M1, M2, M3, M4, M5 in phase I and M6, M7, M8, M9, M10 in phase II. Based on the metabolites of AEE, the pathways of AEE metabolism in dog were demonstrated.

  18. Novel applications of high performance ion chromatography-inductively coupled plasma mass spectrometry (HPIC-ICP-MS)

    CERN Document Server

    Hann, S

    2001-01-01

    This work demonstrates the development of highly sensitive and selective analytical methods, which make use of the hyphenation of high performance ion chromatography (HPIC) to inductively coupled plasma sector field mass spectrometry (ICP-SFMS). On-line coupling a chromatographic separation method with an elemental detection method provides two advantages: (1) the components of a possibly interfering matrix can be separated allowing accurate and precise ultra trace analysis of the element of interest and (2) elemental species of an element can be separated and quantified. In this work, matrix separation methods for interference free determination of 232Th, 234U, 235U and 238U in geological matrices were developed and employed. Furthermore HPIC-ICP-SFMS was applied for ultra trace analysis of Pd in environmental and geological matrices. The usefulness of HPIC-ICP-SFMS for speciation studies was demonstrated by investigating the interaction of an anti-cancer drug (cisplatin) with guanosine monophosphates.

  19. Two-dimensional separation of ionic species by hyphenation of capillary ion chromatography × capillary electrophoresis-mass spectrometry.

    Science.gov (United States)

    Beutner, Andrea; Kochmann, Sven; Mark, Jonas Josef Peter; Matysik, Frank-Michael

    2015-03-17

    The separation of complex mixtures such as biological or environmental samples requires high peak capacities, which cannot be established with a single separation technique. Therefore, multidimensional systems are in demand. In this work, we present the hyphenation of the two most important (orthogonal) techniques in ion analysis, namely, ion chromatography (IC) and capillary electrophoresis (CE), in combination with mass spectrometry. A modulator was developed ensuring a well-controlled coupling of IC and CE separations. Proof-of-concept measurements were performed using a model system consisting of nucleotides and cyclic nucleotides. The data are presented in a multidimensional contour plot. Analyte stacking in the CE separation could be exploited on the basis of the fact that the suppressed IC effluent is pure water.

  20. Capillary ion chromatography-mass spectrometry for simultaneous determination of glucosylglycerol and sucrose in intracellular extracts of cyanobacteria.

    Science.gov (United States)

    Fa, Yun; Liang, Wenhui; Cui, He; Duan, Yangkai; Yang, Menglong; Gao, Jun; Liu, Huizhou

    2015-09-15

    A capillary ion chromatography-mass spectrometry (MS) method was proposed to determine glucosylglycerol (GG), sucrose, and five other carbohydrates. MS conditions and make-up flow parameters were optimized. This method is accurate and sensitive for simultaneous analysis of carbohydrates, with mean correlation coefficients of determination greater than 0.99, relative standard deviation of 0.91-2.81% for eight replicates, and average spiked recoveries of 97.3-104.9%. Limits of detection of sodium adduct were obtained with MS detection in selected ion mode for GG (0.006mg/L), sucrose (0.02mg/L), and other carbohydrates (0.03mg/L). This method was successfully applied to determine GG and sucrose in intracellular extracts of salt-stressed cyanobacteria.

  1. Analysis of 10 systemic pesticide residues in various baby foods using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Yang, Angel; Abd El-Aty, A M; Park, Jong-Hyouk; Goudah, Ayman; Rahman, Md Musfiqur; Do, Jung-Ah; Choi, Ok-Ja; Shim, Jae-Han

    2014-06-01

    Ten systemic pesticides, comprising methomyl, thiamethoxam, acetamiprid, carbofuran, fosthiazate, metalaxyl, azoxystrobin, diethofencarb, propiconazole, and difenoconazole, were detected in 13 baby foods (cereals, boiled potatoes, fruit and milk) using QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) for sample preparation and liquid chromatography tandem mass spectrometry for analysis. The matrix-matched calibration curves showed good linearity with determination coefficients (R(2) ) >0.992. The limits of detection and quantitation were 0.0015-0.003 and 0.005-0.01 mg/kg, respectively. The mean recoveries of three different concentrations ranged from 69.2 to 127.1% with relative standard deviations pesticide residues. This method is suitable for the identification and quantification of systemic pesticides with matrix-matched standards in various baby foods. PMID:24861738

  2. Tequila volatile characterization and ethyl ester determination by solid phase microextraction gas chromatography/mass spectrometry analysis.

    Science.gov (United States)

    Vallejo-Cordoba, Belinda; González-Córdova, Aarón Fernando; del Carmen Estrada-Montoya, María

    2004-09-01

    Solid phase microextraction (SPME) and gas chromatography were used for tequila volatile characterization and ethyl ester quantitation. Several factors determined the differences in tequila volatile profiles obtained by the SPME technique, namely, sampling mode, fiber coating, and fiber exposure time. Each of these factors determined the most suitable conditions for the analysis of volatile profiles in tequila. Volatile extraction consisted of placing 40 mL of tequila in a sealed vial kept at 40 degrees C. A poly(dimethylsiloxane) fiber was immersed in the liquid for 60 min and desorbed for 5 min into the gas chromatograph. The identified volatiles by mass spectrometry were mainly alcohols, esters, and ketones. The calibration curves for ethyl hexanoate, octanoate, and decanoate followed linear relationships with highly significant (p tequila samples. Quantitative differences in ethyl esters were found for the four most commonly known tequila types: silver, gold, aged, and extra-aged.

  3. Detection of lysergic acid diethylamide (LSD) in urine by gas chromatography-ion trap tandem mass spectrometry.

    Science.gov (United States)

    Sklerov, J H; Kalasinsky, K S; Ehorn, C A

    1999-10-01

    A confirmatory method for the detection and quantitation of lysergic acid diethylamide (LSD) is presented. The method employs gas chromatography-tandem mass spectrometry (GC-MS-MS) using an internal ionization ion trap detector for sensitive MS-MS-in-time measurements of LSD extracted from urine. Following a single-step solid-phase extraction of 5 mL of urine, underivatized LSD can be measured with limits of quantitation and detection of 80 and 20 pg/mL, respectively. Temperature-programmed on-column injections of urine extracts were linear over the concentration range 20-2000 pg/mL (r2 = 0.999). Intraday and interday coefficients of variation were LSD-positive samples in this laboratory. Comparisons with alternate GC-MS methods and extraction procedures are discussed.

  4. Comparative analysis of different plant oils by high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

    Science.gov (United States)

    Jakab, Annamaria; Héberger, Károly; Forgács, Esther

    2002-11-01

    Different vegetable oil samples (almond, avocado, corngerm, grapeseed, linseed, olive, peanut, pumpkin seed, soybean, sunflower, walnut, wheatgerm) were analyzed using high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry. A gradient elution technique was applied using acetone-acetonitrile eluent systems on an ODS column (Purospher, RP-18e, 125 x 4 mm, 5 microm). Identification of triacylglycerols (TAGs) was based on the pseudomolecular ion [M+1]+ and the diacylglycerol fragments. The positional isomers of triacylglycerol were identified from the relative intensities of the [M-RCO2]+ fragments. Linear discriminant analysis (LDA) as a common multivariate mathematical-statistical calculation was successfully used to distinguish the oils based on their TAG composition. LDA showed that 97.6% of the samples were classified correctly.

  5. Novel liquid chromatography-mass spectrometry method for sensitive determination of the mustard allergen Sin a 1 in food.

    Science.gov (United States)

    Posada-Ayala, Maria; Alvarez-Llamas, Gloria; Maroto, Aroa S; Maes, Xavier; Muñoz-Garcia, Esther; Villalba, Mayte; Rodríguez, Rosalía; Perez-Gordo, Marina; Vivanco, Fernando; Pastor-Vargas, Carlos; Cuesta-Herranz, Javier

    2015-09-15

    Mustard is a condiment added to a variety of foodstuffs and a frequent cause of food allergy. A new strategy for the detection of mustard allergen in food products is presented. The methodology is based on liquid chromatography analysis coupled to mass spectrometry. Mustard allergen Sin a 1 was purified from yellow mustard seeds. Sin a 1 was detected with a total of five peptides showing a linear response (lowest LOD was 5ng). Sin a 1 was detected in mustard sauces and salty biscuit (19±3mg/kg) where mustard content is not specified. Sin a 1, used as an internal standard, allowed quantification of this mustard allergen in foods. A novel LC/MS/MS SRM-based method has been developed to detect and quantify the presence of mustard. This method could help to detect mustard allergen Sin a 1 in processed foods and protect mustard-allergic consumers.

  6. Analysis of volatile components in a Chinese fish sauce,Fuzhou Yulu, by gas chromatography-mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Yuan-fan YANG; Shen-ru CHEN; Hui NI; Xing-qian YE

    2008-01-01

    Volatile components of Fuzhou Yulu, a Chinese fish sauce, were analyzed by gas chromatography-mass spectrometry (GC-MS), and two pretreatment methods, i.e., purge and trap (P&T) GC-MS and ethyl acetate extraction followed by GC-MS, were compared. P&T-GC-MS method determined 12 components, including sulfur-containing constituents (such as dimethyl disulfide), nitrogen-containing constituents (such as pyrazine derivatives), aldehydes and ketones. Ethyl ace tate extraction fol-lowed by GC-MS method detected 10 components, which were mainly volatile organic acids (such as benzenepropanoic acid) and esters. Neither of the two methods detected alcohols or trimethylamine. This study offers an important reference to determine volatile flavor components of traditional fish sauce through modem analysis methods.

  7. Identification of Phenylethanoid Glycosides in Plant Extract of Plantago asiatica L. by Liquid Chromatography-Electrospray Ionization Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    LI,Li; LIU,Chunming; LIU,Zhiqiang; TSAO,Rong; LIU,Shuying

    2009-01-01

    The present work describes a liquid chromatography-electrospray ionization mass spectrometry(LC-ESI-MS)method for rapid identification of phenylethanoid glycosides in plant extract from Plnmgo asiatica L.By using a binary mobile phase system consisting of 0.2% acetic acid and acetonitrile under gradient conditions,a good sepa-ration was achieved on a reversed-phase C18 column.The[M-H] ions,the molecular weights,and the fragmentions of phenvlethanoid glycosides were obtained in the negative ion mode using LC-ESI-MS.The identification of the phenylethanoid glycosides(peaks 1-3) in the extract of P. asiatica L.was based on matching their retention time.the detection of molecular ions.and the fragment ions obtained by collision-induced dissociation(CID)ex-periments with those of the authentic standards and data reported in the literature.

  8. Application of Gas Chromatography-mass Spectrometry in Analyzing Pharmacokinetics and Distribution of Deltamethrin in Miniature Pig Tissues

    Institute of Scientific and Technical Information of China (English)

    ZHU Pan; FAN Sai; ZOU Jian Hong; MIAO Hong; LI Jing Guang; ZHANG Guo Wen; WU Yong Ning

    2014-01-01

    Objective To characterize the pharmacokinetics and distribution profiles of deltamethrin in miniature pig tissues by gas chromatography-mass spectrometry (GC-MS). Methods Pharmacokinetics and distribution of deltamethrin in blood and tissues of 30 miniature pigs were studied by GC-MS after oral administration of deltamethrin (5 mg/kg bw). Data were processed by 3P97 software. Results The serum deltamethrin level was significantly lower in tissues than in blood of miniature pigs. The AUC0-72 h, Cmax, of deltamethrin were 555.330±316.987 ng h/mL and 17.861±11.129 ng/mL, respectively. The Tmax, of deltamethrin was 6.004±3.131 h. Conclusion The metabolism of deltamethrin in miniature pigs is fit for a one-compartment model with a weighting function of 1/C2. Deltamethrin is rapidly hydrolyzed and accumulated in miniature pig tissues.

  9. The use of liquid chromatography tandem mass spectrometry to detect proteins in saliva from horses with and without systemic inflammation.

    Science.gov (United States)

    Jacobsen, Stine; Top Adler, Ditte Marie; Bundgaard, Louise; Sørensen, Mette Aamand; Andersen, Pia Haubro; Bendixen, Emøke

    2014-12-01

    The objective of the study was to assess global expression of proteins in equine saliva using liquid chromatography tandem mass spectrometry (LC-MS/MS). Saliva was obtained from seven horses with and six horses without evidence of systemic inflammatory disease. Tryptic peptides from saliva were analysed by LC-MS/MS. Of 195 unique proteins identified, 57 were detected only in saliva samples from horses with systemic inflammation (in two to six of the seven horses). Among the differentially expressed proteins were several acute phase proteins (APPs) such as serum amyloid A, fibrinogen, haptoglobin, and alpha1-acid glycoprotein. The study is the first to describe detection of inflammatory proteins in horse saliva. The proteins detected were similar to those described in saliva from cattle, small ruminants and pigs. Detection of APPs in horses with systemic inflammation suggests that saliva may be used for non-invasive disease monitoring in horses as in humans, pigs and dogs. PMID:25296850

  10. The use of liquid chromatography tandem mass spectrometry to detect proteins in saliva from horses with and without systemic inflammation

    DEFF Research Database (Denmark)

    Jacobsen, Stine; Top Adler, Ditte Marie; Bundgaard, Louise;

    2014-01-01

    The objective of the study was to assess global expression of proteins in equine saliva using liquid chromatography tandem mass spectrometry (LC-MS/MS). Saliva was obtained from seven horses with and six horses without evidence of systemic inflammatory disease. Tryptic peptides from saliva were...... analysed by LC-MS/MS. Of 195 unique proteins identified, 57 were detected only in saliva samples from horses with systemic inflammation (in two to six of the seven horses). Among the differentially expressed proteins were several acute phase proteins (APPs) such as serum amyloid A, fibrinogen, haptoglobin......, and alpha1-acid glycoprotein. The study is the first to describe detection of inflammatory proteins in horse saliva. The proteins detected were similar to those described in saliva from cattle, small ruminants and pigs. Detection of APPs in horses with systemic inflammation suggests that saliva may be...

  11. Characterisation of honeys according to their content of phenolic compounds using high performance liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Sergiel, Iwona; Pohl, Pawel; Biesaga, Magdalena

    2014-02-15

    A simple, fast and specific high performance liquid chromatography separation with an electro-spray ionisation tandem mass spectrometry detection in a negative single reaction ion monitoring scan mode was developed and used for the characterization of Polish honeys according to the content of phenolic acids, including caffeic, chlorogenic, p-coumaric, ferulic, homogentisic, p-hydroxybenzoic and vanillic acids, and flavonoids, i.e., apigenin, genistein, hesperetin, kaempferol, luteolin, rhamnetin, rutin, tricetin and quercetin. Target compounds were isolated and pre-concentrated from the honey matrix by means of the solid phase extraction using Strata X (500mg) cartridges. Analysed honeys did not contain tricetin and genistein. Hesperetin was determined for the first time in heather and linden honeys while rutin in rape honey. PMID:24128495

  12. Analysis of volatile chemical components of Radix Paeoniae Rubra by gas chromatography-mass spectrometry and chemometric resolution

    Institute of Scientific and Technical Information of China (English)

    LI Xiao-ru; LAN Zheng-gang; LIANG Yi-zeng

    2007-01-01

    The volatile chemical components of Radix Paeoniae Rubra (RPR) were analyzed by gas chromatography-mass spectrometry with the method of heuristic evolving latent projections and overall volume integration.The results show that 38 volatile chemical components of RPR are determined.accounting for 95.21% of total contents of volatile chemical components of RPR.The main volatile chemical components of RPR are(Z,Z)-9, 12-octadecadienoic acid, n-hexadecanoic acid, 2-hydroxy benzaldehyde, 1-(2-hydroxy-4-methoxyphenyl)-ethanone, 6,6-dimethyl-bicyclo[3.1.1]heptane-2-methanol, 4,7-dimethyl-benzofuran, 4-(1-methylethenyl)-1-cyclohexene-1-carboxaldehyde, and cyclohexadecane.

  13. Advanced analytical techniques for the extraction and characterization of plant-derived essential oils by gas chromatography with mass spectrometry.

    Science.gov (United States)

    Waseem, Rabia; Low, Kah Hin

    2015-02-01

    In recent years, essential oils have received a growing interest because of the positive health effects of their novel characteristics such as antibacterial, antifungal, and antioxidant activities. For the extraction of plant-derived essential oils, there is the need of advanced analytical techniques and innovative methodologies. An exhaustive study of hydrodistillation, supercritical fluid extraction, ultrasound- and microwave-assisted extraction, solid-phase microextraction, pressurized liquid extraction, pressurized hot water extraction, liquid-liquid extraction, liquid-phase microextraction, matrix solid-phase dispersion, and gas chromatography (one- and two-dimensional) hyphenated with mass spectrometry for the extraction through various plant species and analysis of essential oils has been provided in this review. Essential oils are composed of mainly terpenes and terpenoids with low-molecular-weight aromatic and aliphatic constituents that are particularly important for public health.

  14. Potato glycoalkaloids in soil-optimising liquid chromatography-time-of-flight mass spectrometry for quantitative studies.

    Science.gov (United States)

    Jensen, Pia H; Juhler, René K; Nielsen, Nikoline J; Hansen, Thomas H; Strobel, Bjarne W; Jacobsen, Ole S; Nielsen, John; Hansen, Hans Christian B

    2008-02-22

    Potato glycoalkaloids are produced in high amounts in potato fields during the growth season and losses to soil potentially impact shallow groundwater and via tiles to fresh water ecosystems. A quantitative liquid chromatography-electrospray ionization time-of-flight mass spectrometry (LC-ESI-TOF-MS) method for determination and quantification of potato glycoalkaloids and their metabolites in aqueous soil extracts was developed. The LC-ESI-TOF-MS method had linearities up to 2000microg/L for alpha-solanine and alpha-chaconine and up to 760microg/L for solanidine. No matrix effect was observed, and the detection limits found were in the range 2.2-4.7microg/L. The method enabled quantification of the potato glycoalkaloids in environmental samples.

  15. Quantitative analysis of [Dmt(1)]DALDA in ovine plasma by capillary liquid chromatography-nanospray ion-trap mass spectrometry.

    Science.gov (United States)

    Wan, Haibao; Umstot, Edward S; Szeto, Hazel H; Schiller, Peter W; Desiderio, Dominic M

    2004-04-15

    The synthetic opioid peptide analog Dmt-D-Arg-Phe-Lys-NH(2) ([Dmt(1)]DALDA; [Dmt= 2',6'-dimethyltyrosine) is a highly potent and selective mu opioid-receptor agonist. A very sensitive and robust capillary liquid chromatography/nanospray ion-trap (IT) mass spectrometry method has been developed to quantify [Dmt(1)]DALDA in ovine plasma, using deuterated [Dmt(1)]DALDA as the internal standard. The standard MS/MS spectra of d(0)- and d(5)-[Dmt(1)]DALDA were obtained, and the collision energy was experimentally optimized to 25%. The product ion [ M + 2H-NH(3)](2+) (m/z 312.2) was used to identify and to quantify the synthetic opioid peptide analog in ovine plasma samples. The MS/MS detection sensitivity for [Dmt(1)]DALDA was 625 amol. A calibration curve was constructed, and quantitative analysis was performed on a series of ovine plasma samples.

  16. Comparative analysis of different plant oils by high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

    Science.gov (United States)

    Jakab, Annamaria; Héberger, Károly; Forgács, Esther

    2002-11-01

    Different vegetable oil samples (almond, avocado, corngerm, grapeseed, linseed, olive, peanut, pumpkin seed, soybean, sunflower, walnut, wheatgerm) were analyzed using high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry. A gradient elution technique was applied using acetone-acetonitrile eluent systems on an ODS column (Purospher, RP-18e, 125 x 4 mm, 5 microm). Identification of triacylglycerols (TAGs) was based on the pseudomolecular ion [M+1]+ and the diacylglycerol fragments. The positional isomers of triacylglycerol were identified from the relative intensities of the [M-RCO2]+ fragments. Linear discriminant analysis (LDA) as a common multivariate mathematical-statistical calculation was successfully used to distinguish the oils based on their TAG composition. LDA showed that 97.6% of the samples were classified correctly. PMID:12462617

  17. Development and evaluation of a liquid chromatography tandem mass spectrometry method for simultaneous determination of salivary melatonin, cortisol and testosterone

    DEFF Research Database (Denmark)

    Jensen, Marie Aarrebo; Hansen, Åse Marie; Abrahamsson, Peter;

    2011-01-01

    saliva. We used liquid-liquid extraction (LLE) followed by liquid chromatography coupled to electrospray tandem mass spectrometry (LC-ESI-MS/MS) recorded in positive ion mode. Saliva samples were collected by spitting directly into tubes and 250 µL were used for analysis. The limits of detection were 4......Circadian disruption can have several possible health consequences, but is not well studied. In order to measure circadian disruption, in relation to shift or night work, we developed a simple and sensitive method for the simultaneous determination of melatonin, cortisol and testosterone in human.......1 pmol/L, 0.27 nmol/L and 10.8 pmol/L for melatonin, cortisol, and testosterone, respectively. The developed method was sensitive enough to measure circadian rhythms of all 3 hormones in a pilot study among four healthy volunteers. It can therefor be used to study the impact of night work and working...

  18. Determination of seven bisphenol analogues in reed and Callitrichaceae by ultra performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lu, Libin; Yang, Yunjia; Zhang, Jing; Shao, Bing

    2014-03-15

    An analytical procedure was developed to simultaneously determine bisphenol S, bisphenol F, bisphenol B, bisphenol A, bisphenol AF, tetrachlorobisphenol A, and tetrabromobisphenol A in reed and Callitrichaceae. Homogenized samples were extracted with acetonitrile and purified using an ENVI™-Carb cartridge followed by an NH2 cartridge. The analytes were separated and quantified by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The recoveries at three fortified levels in reed and Callitrichaceae were 57-108% and 68-106%, respectively, with relative standard deviations of no more than 15% (n=6). The method limits of quantification and detection for the seven bisphenol analogues were 0.005-0.500μg/kg and 0.002-0.150μg/kg, respectively. This method was used to analyze the seven compounds in ten reed and Callitrichaceae samples collected from Zhejiang, China.

  19. Gas chromatography-mass spectrometry analysis of fatty acid profiles of Antarctic and non-Antarctic yeasts.

    Science.gov (United States)

    Bhuiyan, Mohammad; Tucker, David; Watson, Kenneth

    2014-08-01

    The fatty acid profiles of Antarctic (n = 7) and non-Antarctic yeasts (n = 7) grown at different temperatures were analysed by gas chromatography-mass spectrometry. The Antarctic yeasts were enriched in oleic 18:1 (20-60 %), linoleic 18:2 (20-50 %) and linolenic 18:3 (5-40 %) acids with lesser amounts of palmitic 16:0 (Antarctic yeasts (n = 4) were enriched in 18:1 (20-55 %, with R. mucilaginosa at 75-80 %) and 18:2 (10-40 %) with lesser amounts of 16:0 (Antarctic yeasts (enriched in 18:1 and 18:2) and the third to the Antarctic yeasts (enriched in 18:2 and 18:3).

  20. Rapid determination of vitamin D₃ in milk-based infant formulas by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kwak, Byung-Man; Jeong, In-Seek; Lee, Moon-Seok; Ahn, Jang-Hyuk; Park, Jong-Su

    2014-12-15

    A rapid and simple sample preparation method for vitamin D3 (cholecalciferol) was developed for emulsified dairy products such as milk-based infant formulas. A sample was mixed in a 50 mL centrifuge tube with the same amount of water and isopropyl alcohol to achieve chemical extraction. Ammonium sulfate was used to induce phase separation. No-heating saponification was performed in the sample tube by adding KOH, NaCl, and NH3. Vitamin D3 was then separated and quantified using liquid chromatography-tandem mass spectrometry. The results for added recovery tests were in the range 93.11-110.65%, with relative standard deviations between 2.66% and 2.93%. The results, compared to those obtained using a certified reference material (SRM 1849a), were within the range of the certificated values. This method could be implemented in many laboratories that require time and labour saving.

  1. [Simultaneous determination of six synthetic sweeteners in food by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Liu, Xiaoxi; Ding, Li; Liu, Jinxia; Zhang, Ying; Huang, Zhiqiang; Wang, Libing; Chen, Bo

    2010-11-01

    A simple and sensitive method for the determination of six synthetic sweeteners (sodium cyclamate, saccharin sodium, acesulfame-K, aspartame, alitame and neotame) in food was developed. The synthetic sweeteners were extracted by methanol-water (1 : 1, v/v). The extract was separated on a C18 column using 0.1% (v/v) formic acid-5 mmol/L ammonium formate/acetonitrile as mobile phase, and then detected by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) using multiple reaction monitoring (MRM) mode. The good linearities (r > 0.998) were achieved for all the analytes over the range of 20-500 microg/L. The recoveries obtained ranged from 81.3% to 106.0% at three spiked concentrations, with the relative standard deviations lower than 11%. The established method has been successfully applied to the determination of synthetic sweeteners in food. PMID:21381416

  2. Hydrocarbon gases emitted from vehicles on the road. 1. A qualitative gas chromatography/mass spectrometry survey

    Energy Technology Data Exchange (ETDEWEB)

    Hampton, C.V.; Pierson, W.R.; Harvey, T.M.; Updegrove, W.S.; Marano, R.S.

    1982-05-01

    The gas-phase hydrocarbons greater than or equal to C/sub 5/ generated by motor vehicles in highway operation were surveyed in the Allegheny Mountain Tunnel of the Pennsylvania Turnpike in 1979. The samples were collected on Tenax GC polymer adsorbent and analyzed by glass-capillary gas chromatography/mass spectrometry. Approximately 400 vehicle-generated compounds were detected. Of these, over 300 were either completely or partially identified. In the various tunnel samples the same peaks are always present, with relative intensities varying according to the traffic composition. The compounds identified fall largely into homolgous series of normal and branched alkanes, alkenes, and various alkyl series based on cyclopentane, cyclohexane, benzene, styrene, indan, naphthalene, and decalin. Compounds not associated with homolgous series include indene, divinylbenzene, phenylacetylene, benzaldehyde, phenol, and a few halocarbons. Results from a preliminary experiment in 1977 at the Tuscarora Mountain Tunnell are also reported.

  3. Determination of cocaine and benzoylecgonine in nails by liquid chromatography-electrospray ionization-tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Marzena Sykutera

    2015-02-01

    Full Text Available Nails and hair are a biological matrix which can be analyzed to confirm the use of a xenobiotic even several months after intake. Results of nail analysis can be used, for example, as evidence in civil and criminal law cases in which a history of drug use can influence the court’s decision. The paper presents results of analysis of a nail sample taken from a man who was suspected of trafficking cocaine. The suspect pleaded guilty to the possession of the drug for his own use because, as he claimed, he was addicted to cocaine. A nail sample was taken. Detection and quantification were carried out using liquid chromatography-mass spectrometry (LC-ESI-MS. The concentration of cocaine in nails was found to be 47 ng/mg, and benzoylecgonine – 14 ng/mg.

  4. Modernization of Chinese herbal compound and the high performance liquid chromatography tandem mass spectrometry (HPLC-MS)

    Institute of Scientific and Technical Information of China (English)

    LI Wen-lan; SUN Zhi; DU Juan

    2008-01-01

    Chinese herbal compound is playing an important role on curing human diseases. And it has been a trend that Chinese herbal compound is being used all over the world in 21 century. However, our Chinese herbal compound is facing serious challenge for the lack of canonical system of quality criterion for Chinese herbal compound so it has been a urgent problem to set up the quality control standards and reveal therapeutic basis of Chinese herbal compound. In order to give full play to the advantages of Chinese herbal compound, modern scientific and technological is used to research of Chinese herbal compound, especially the high performance liquid chromatography tandem mass spectrometry(HPLC-MS), because it is high sensitive, rapid, and obtain more information. It is very necessary that HPLC-MS is uesed to elucidate the effective components of basic substances of Chinese Herbal Compound, and endow traditional Chinese medicine with modern scientific connotation.

  5. Identification and quantitation of glycosidically bound aroma compounds in three tobacco types by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Cai, Kai; Xiang, Zhangmin; Pan, Wenjie; Zhao, Huina; Ren, Zhu; Lei, Bo; Geng, Zhaoliang

    2013-10-11

    Glycosidically bound aroma compounds in three different types of tobacco were investigated. After isolation of extracts obtained by Amberlite XAD-2 adsorption and ethyl acetate elution, glycosides were analyzed after enzymatic hydrolysis by gas chromatography-mass spectrometry (GC-MS) or directly after trifluoroacetylated (TFA) derivatization by GC-MS in electron ionization (EI) and negative chemical ionization (NCI) mode. In total 21 bound aglycones were identified by β-glucosidase hydrolysis. These aglycones mainly consisted of C13-norisoprenoids, aromatic components and sesquiterpenoids. Additionally, with the aid of enzymatic hydrolysis, 15 β-d-glucopyranosides and 1 β-d-rutinoside were tentatively identified by TFA derivatization. TFA method was validated by repeatability and successfully employed to analyze different types of tobacco. Principal component analysis (PCA) was carried out on identified glycoside variables to visualize the difference between the tobacco types and the relationship between the glycoside variables and the tobacco types was established. PMID:24011421

  6. Determination of trace mercury species by high performance liquid chromatography-inductively coupled plasma mass spectrometry after cloud point extraction.

    Science.gov (United States)

    Chen, Haiting; Chen, Jianguo; Jin, Xianzhong; Wei, Danyi

    2009-12-30

    A sensitive method for speciation analysis of inorganic mercury (Hg(2+)) and methyl mercury (MeHg(+)) has been developed by using high performance liquid chromatography (HPLC) combined with inductively coupled plasma mass spectrometry (ICP-MS) after cloud point extraction. The analytes were complexed with sodium diethyldithiocarbamate (DDTC) and preconcentrated by a non-ionic surfactant Triton X-114. Mercury species were effectively separated by HPLC in less than 6 min. The enhancement factors for 25 mL sample solution were 42 and 21, and the limits of detection were 4 and 10 ng L(-1) for Hg(2+) and MeHg(+), respectively. The developed method was successfully applied to the determination of trace amount of mercury species in environmental and biological samples.

  7. Liquid chromatography-high-resolution mass spectrometry for pesticide residue analysis in fruit and vegetables: screening and quantitative studies.

    Science.gov (United States)

    Gómez-Ramos, M M; Ferrer, C; Malato, O; Agüera, A; Fernández-Alba, A R

    2013-04-26

    This work reviews the current state-of-the-art of liquid chromatography coupled to high-resolution mass spectrometry (LC-HRMS) techniques applied to the analysis of pesticides in fruit-based and vegetable-based matrices. Nowadays, simultaneous trace analysis of hundreds of pesticides from different classes is required, preferably in just one run. The most commonly used QqQ-MS technology presents certain limitations in its application in a cost and effective way when analyzing a large number of pesticides. Thus, this review includes HRMS technology as a reliable complementary alternative allowing the analysis of a wide range of pesticides in food. Its capabilities and limitations in identifying, confirming and quantifying pesticides are discussed. HRMS instruments can adequately address such issues; however, the main drawbacks are as a result of insufficient prior optimization of the operational parameters during non-target analysis in full-scan mode and due to software shortcomings.

  8. Determination of chlorinated acid herbicides in vegetation and soil by liquid chromatography/electrospray-tandem mass spectrometry.

    Science.gov (United States)

    Schaner, Angela; Konecny, Jaclyn; Luckey, Laura; Hickes, Heidi

    2007-01-01

    The method presented uses reversed-phase liquid chromatography with negative electrospray ionization and tandem mass spectrometry to analyze 9 chlorinated acid herbicides in soil and vegetation matrixes: clopyralid, dicamba, MCPP, MCPA, 2,4-DP, 2,4-D, triclopyr, 2,4-DB, and picloram. A 20 g portion is extracted with a basic solution and an aliquot acidified and micropartitioned with 3 mL chloroform. Vegetation samples are subjected to an additional cleanup with a mixed-mode anion exchange solid-phase extraction cartridge. Two precursor product ion transitions per analyte are measured and evaluated to provide the maximum degree of confidence in results. Average recoveries for 3 different soil types tested ranged from 72 to 107% for all compounds with the exception of 2,4-DB at 56-99%. Average recoveries for the 3 different vegetation types studied were lower and ranged from 53 to 80% for all compounds. PMID:17955986

  9. Development of rapid determination of 18 phthalate esters in edible vegetable oils by gas chromatography tandem mass spectrometry.

    Science.gov (United States)

    Liu, Yinping; Wang, Shuhui; Wang, Li

    2013-02-13

    A simultaneous and fast determination of 18 phthalic acid esters (PAEs) in edible vegetable oils was developed. After solvent extraction, the PAEs in the oil sample were further cleaned up by solid-phase extraction. After concentration, the extract was directly injected into gas chromatography tandem mass spectrometry (GC-MS/MS) in positive-ion electron impact (EI) mode. Method quantification limits of 18 PAEs were between 0.01 and 0.1 mg/kg. Quantitative recoveries ranging from 63.9 to 115.3% were obtained by analysis of spiked oil. The relative standard deviations were less than 15% (n = 6). The method could potentially overcome the interference from large amounts of lipids and pigment. It was applied to real sample and shown to be a rapid and reliable alternative for determination and confirmation of PAEs in routine analysis. PMID:23339279

  10. Headspace solid-phase microextraction for characterization of fragrances of lemon verbena (Aloysia triphylla) by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Kim, Nam-Sun; Lee, Dong-Sun

    2004-01-01

    Natural fragrances from lemon verbena (Aloysia triphylla) were studied by headspace solid phase microextraction (HS-SPME) techniques followed by gas chromatography-mass spectrometry (GC-MS), with six different fibre coatings being tested to evaluate the extraction efficiencies of several selected compounds. A total of 14 compounds were identified in the fragrances of lemon verbena. Geranial and neral were detected as major components and alpha-pinene, beta-pinene, beta-caryophyllene, and curcumene as minor components. Enantiomeric analysis of chiral compounds from lemon verbena was carried out on a chiral column. alpha-Pinene, limonene, and camphor in the fragrances emitted from lemon verbena were found in the (+), (-), and (-) forms, respectively. PMID:15335064

  11. Urinary metabonomics of stomach cancer assessed by rapid resolution liquid chromatography/time-of-flight mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    ZHANG Yan; REN Hui; JIANG Yang; GAO Yu-fei; LIU Shu-ying

    2013-01-01

    Background Stomach cancer is among the most commonly occurring malignancies worldwide.It would be beneficial to develop a urine-based assay whereby patients with undiagnosed stomach cancer could be screened and their cancer detected in the earliest stages.Methods A urinary metabonomics method based on ultra-performance liquid chromatography combined with quadruple time-of-flight mass spectrometry was used to analyze urine samples from patients with stomach cancer and healthy controls.Results Statistical analysis revealed a clear separation of patients and healthy controls using the aforementioned methodology.Some significantly changed metabolites were identified.Conclusions Use of the metabonomics method in patients with stomach cancer could effectively detect distinct changes in urinary metabolites and had the capacity to detect cancer; therefore,it may be a valuable tool in earlier diagnosis.Furthermore,the detection and identification of altered metabolites in the current study may help elucidate possible mechanisms involved in stomach cancer.

  12. Novel applications of high performance ion chromatography-inductively coupled plasma mass spectrometry (HPIC-ICP-MS)

    International Nuclear Information System (INIS)

    This work demonstrates the development of highly sensitive and selective analytical methods, which make use of the hyphenation of high performance ion chromatography (HPIC) to inductively coupled plasma sector field mass spectrometry (ICP-SFMS). On-line coupling a chromatographic separation method with an elemental detection method provides two advantages: (1) the components of a possibly interfering matrix can be separated allowing accurate and precise ultra trace analysis of the element of interest and (2) elemental species of an element can be separated and quantified. In this work, matrix separation methods for interference free determination of 232Th, 234U, 235U and 238U in geological matrices were developed and employed. Furthermore HPIC-ICP-SFMS was applied for ultra trace analysis of Pd in environmental and geological matrices. The usefulness of HPIC-ICP-SFMS for speciation studies was demonstrated by investigating the interaction of an anti-cancer drug (cisplatin) with guanosine monophosphates. (author)

  13. Characterization of iodinated disinfection by-products in chlorinated and chloraminated waters using Orbitrap based gas chromatography-mass spectrometry.

    Science.gov (United States)

    Postigo, Cristina; Cojocariu, Cristian I; Richardson, Susan D; Silcock, Paul J; Barcelo, Damia

    2016-05-01

    Recent developments in gas chromatography (GC)-mass spectrometry (MS) have opened up the possibility to use the high resolution-accurate mass (HRAM) Orbitrap mass analyzer to further characterize the volatile and semivolatile fractions of environmental samples. This work describes the utilization of GC Orbitrap MS technology to characterize iodine-containing disinfection by-products (iodo-DBPs) in chlorinated and chloraminated DBP mixture concentrates. These DBP mixtures were generated in lab-scale disinfection reactions using Llobregat river water and solutions containing Nordic Lake natural organic matter (NOM). The DBPs generated were concentrated using XAD resins, and extracts obtained were analyzed in full scan mode with the GC Orbitrap MS. Integration of high resolution accurate mass information and fragment rationalization allowed the characterization of up to 11 different iodo-DBPs in the water extracts analyzed, including one new iodo-DBP reported for the first time. Overall, formation of iodo-DBPs was enhanced during chloramination reactions. As expected, NOM characteristics and iodide and bromide content of the tested waters affected the amount and type of iodo-DBPs generated. Graphical Abstract Characterization of iodo-DBPs in DBP mixtures based on high resolution accurate mass data obtained by means of GC Orbitrap MS analysis. PMID:27007731

  14. A simple and selective liquid chromatography- tandem mass spectrometry method for determination of ε-aminocaproic acid in human plasma

    Directory of Open Access Journals (Sweden)

    Ganesh S. Moorthy

    2015-07-01

    Full Text Available Understanding the clinical pharmacology of the antifibrinolytic drug epsilon-aminocaproic acid (EACA is critical for rational drug administration in children. The aim of this study is to develop a reliable assay for the determination of EACA in human plasma. We describe a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS assay for EACA in human plasma. Sample preparation involved plasma dilution (1:2040, followed by reversed-phase chromatographic separation and selective detection using tandem mass spectrometry. EACA had a linear range of 1 - 250 μg/mL. The intraday precision based on the standard deviation of replicates of quality control samples ranged from 4.7 to 10.4% and the accuracy ranged from 92-106%. The interday precision ranged from 4.6 to 9.8% and the accuracy ranged from 95-103%. Stability studies showed that EACA was stable during the conditions for sample preparation and storage. The described method is robust and successfully employed for clinical studies of EACA in children

  15. Ion chromatography-mass spectrometry: a review of recent technologies and applications in forensic and environmental explosives analysis.

    Science.gov (United States)

    Barron, Leon; Gilchrist, Elizabeth

    2014-01-01

    The development and application of ion chromatography (IC) coupled to mass spectrometry (MS) is discussed herein for the quantitative determination of low-order explosives-related ionic species in environmental and forensic sample types. Issues relating to environmental explosives contamination and the need for more confirmatory IC-MS based applications in forensic science are examined. In particular, the compatibility of a range of IC separation modes with MS detection is summarised along with the analytical challenges that have been overcome to facilitate determinations at the ng-μg L(-1) level. Observed trends in coupling IC to inductively coupled plasma and electrospray ionisation mass spectrometry form a particular focus. This review also includes a discussion of the relative performance of reported IC-MS methods in comparison to orthogonal ion separation-based, spectrometric and spectroscopic approaches to confirmatory detection of low-order explosives. Finally, some promising areas for future research are highlighted and discussed with respect to potential IC-MS applications.

  16. Quantification of γ-Aminobutyric Acid in Cerebrospinal Fluid Using Liquid Chromatography-Electrospray Tandem Mass Spectrometry.

    Science.gov (United States)

    Arning, Erland; Bottiglieri, Teodoro

    2016-01-01

    We describe a simple stable isotope dilution method for accurate and precise measurement of γ-aminobutyric acid (GABA), a major inhibitory neurotransmitter in human cerebrospinal fluid (CSF) as a clinical diagnostic test. Determination of GABA in CSF (50 μL) was performed utilizing high performance liquid chromatography coupled with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Analysis of free and total GABA requires two individual sample preparations and mass spectrometry analyses. Free GABA in CSF is determined by a 1:2 dilution with internal standard (GABA-D2) and injected directly onto the HPLC-ESI-MS/MS system. Determination of total GABA in CSF requires additional sample preparation in order to hydrolyze all the bound GABA in the sample to the free form. This requires hydrolyzing the sample by boiling in acidic conditions (hydrochloric acid) for 4 h. The sample is then further diluted 1:10 with a 90 % acetonitrile/0.1 % formic acid solution and injected into the HPLC-ESI-MS/MS system. Each assay is quantified using a five-point standard curve and is linear from 6 nM to 1000 nM and 0.63 μM to 80 μM for free and total GABA, respectively. PMID:26602123

  17. Simultaneous determination of six phenolic constituents of danshen in human serum using liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Li, Xiaochuan; Yu, Chen; Cai, Yongbao; Liu, Gangyi; Jia, Jingying; Wang, Yiping

    2005-06-01

    The six phenolic constituents are water-soluble components extracted from the Chinese medical herb danshen, the dried roots of Salvia miltiorrhiza Bunge (Labiatae). An liquid chromatography/tandem mass spectrometry (LC/MS/MS)-based method has been developed for the simultaneous quantification of six phenolic constituents of danshen (magnesium lithospermate B (MLB), rosmarinic acid (RA) and lithospermic acid (LA), caffeic acid (CAA), protocatechuic aldehyde (3,4-dihydroxybenzaldehyde, Pal), 3,4-dihydroxyphenyllactic acid (danshensu)) in human serum with chloramphenicol as internal standard. The serum samples were treated by special liquid-liquid extraction, and the analytes were determined using electrospray negative ionization mass spectrometry in the multiple reaction monitoring (MRM) mode, with sufficient sensitivity to allow analysis of human serum samples generated following administration of a clinically relevant dose. Good linearity over the range 8-2048 ng/mL for six phenolic constituents was observed. The intra- and inter-day precisions (CV) of analysis were <13%, and the accuracy ranged from 88 to 116%. This quantitation method was successfully applied to a pharmacokinetic study of i.v. drip infusion of Danshen injection fluid in human. PMID:15866491

  18. Simultaneous analysis of ten phytohormones in Sargassum horneri by high-performance liquid chromatography with electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Li, Yan; Zhou, Chengxu; Yan, Xiaojun; Zhang, Jinrong; Xu, Jilin

    2016-05-01

    Phytohormones have attracted wide attention due to their important biological functions. However, their detection is still a challenge because of their complex composition, low abundance and diverse sources. In this study, a novel method of high-performance liquid chromatography with electrospray ionization tandem mass spectrometry was developed and validated for the simultaneous determination of ten phytohormones including indole-3-acetic acid, isopentenyladenine, isopentenyl adenosine, trans-zeatin riboside, zeatin, strigolactones, abscisic acid, salicylic acid, gibberellin A3, and jasmonic acid in Sargassum horneri (S. horneri). The phytohormones were extracted from freeze-dried S. horneri with methanol/water/methanoic acid (15:4:1, v/v/v) analyzed on a Hypersil Gold C18 column and detected by electrospray ionization tandem triple quadrupole mass spectrometry in the multiple reaction monitoring mode. The experimental conditions for the extraction and analysis of phytohormones were optimized and validated in terms of reproducibility, linearity, sensitivity, recovery, accuracy, and stability. Distributions of the phytohormones in the stems, blades, and gas bladder of the S. horneri in drift, fixed, and semi-fixed growing states were investigated for the first time. The observed contents of the phytohormones in S. horneri range from not detected to 5066.67 ng/g (fresh weight). Most phytohormones are distributed mainly in the stems of S. horneri in drift and semi-fixed states. PMID:26990813

  19. Characterisation of a proposed internet synthesis of N,N-dimethyltryptamine using liquid chromatography/electrospray ionisation tandem mass spectrometry.

    Science.gov (United States)

    Martins, Cláudia P B; Freeman, Sally; Alder, John F; Brandt, Simon D

    2009-08-14

    The psychoactive properties of N,N-dimethyltryptamine (DMT) are known to induce altered states of consciousness in humans. These properties attract great interest from clinical, neuroscientific, clandestine and forensic communities. The Breath of Hope Synthesis was reported on an internet website as a convenient two-step methodology for the preparation of DMT. The analytical characterisation of the first stage was the subject of previous publications by the authors and involved the thermal decarboxylation of tryptophan and the formation of tryptamine. The present study reports on the characterisation of the second step of this procedure which was based on the methylation of tryptamine. This employed methyl iodide and benzyltriethylammonium chloride/sodium hydroxide as a phase transfer catalyst. The reaction product was characterised by liquid chromatography/electrospray ionisation tandem mass spectrometry and orthogonal acceleration time-of-flight mass spectrometry. Quantitative evaluation was carried out in positive multiple reaction monitoring mode (MRM), which included synthesis of the identified reaction products. MRM screening of the product did not lead to the detection of DMT. Instead, 11.1% tryptamine starting material, 21.0% N,N,N-trimethyltryptammonium iodide (TMT) and 47.4% 1-N-methyl-TMT were detected. A 0.5% trace of the monomethylated N-methyltryptamine was also detected. This study demonstrated the impact on product purity of doubtful synthetic methodologies discussed on the internet. PMID:19592003

  20. Quantitative Analysis of Cytokinins in Plants by High Performance Liquid Chromatography: Electronspray Ionization Ion Trap Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    Weiqi Chen; Ying Gai; Shichang Liu; Renxiao Wang; Xiangning Jiang

    2010-01-01

    The present paper introduces a highly sensitive and selective method for simultaneous quantification of 12 cytokinins(free form and their conjugates).The method includes a protocol of extraction with methanol/water/formic acid(1514/1,v/v/v)to the micro-scale samples,pre-purification with solid phase extraction(SPE)cartridges of the extracts,separation with a high performance liquid chromatography(HPLC)and detection by an electrospray ionization ion trap mass spectrometry(ESI-Ion trap-MS)system in a consecutive ion monitoring(CRM)mode at the three stage fragmentation of mass spectrometry(MS3).The lowest detection level of the cytokinins of the method reaches 0.1-2.0 pg with a very wide range of linear regression from 1-512 pg,at the coefficient factors of 0.98-0.99.The feasibility of this method has been proven in the application of the method to the analysis of the trace-amount contents of cytokinins in the micro-scale samples of various types of plant materials,such as aerial parts of rice and poplar leaves etc.12 endogenous cytokinins had been identified and quantified in the plant tissues,with an acceptable relatively higher recovery rate from 40% to 70%.

  1. Quantitation of protein S-glutathionylation by liquid chromatography-tandem mass spectrometry: correction for contaminating glutathione and glutathione disulfide.

    Science.gov (United States)

    Bukowski, Michael R; Bucklin, Christopher; Picklo, Matthew J

    2015-01-15

    Protein S-glutathionylation is a posttranslational modification that links oxidative stimuli to reversible changes in cellular function. Protein-glutathione mixed disulfide (PSSG) is commonly quantified by reduction of the disulfide and detection of the resultant glutathione species. This methodology is susceptible to contamination by free unreacted cellular glutathione (GSH) species, which are present in 1000-fold greater concentration. A liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based method was developed for quantification of glutathione and glutathione disulfide (GSSG), which was used for the determination of PSSG in biological samples. Analysis of rat liver samples demonstrated that GSH and GSSG coprecipitated with proteins similar to the range for PSSG in the sample. The use of [(13)C2,(5)N]GSH and [(13)C4,(5)N2]GSSG validated these results and demonstrated that the release of GSH from PSSG did not occur during sample preparation and analysis. These data demonstrate that GSH and GSSG contamination must be accounted for when determining PSSG content in cellular/tissue preparations. A protocol for rinsing samples to remove the adventitious glutathione species is demonstrated. The fragmentation patterns for glutathione were determined by high-resolution mass spectrometry, and candidate ions for detection of PSSG on protein and protein fragments were identified.

  2. Development and evaluation of a liquid chromatography-mass spectrometry method for rapid, accurate quantitation of malondialdehyde in human plasma.

    Science.gov (United States)

    Sobsey, Constance A; Han, Jun; Lin, Karen; Swardfager, Walter; Levitt, Anthony; Borchers, Christoph H

    2016-09-01

    Malondialdhyde (MDA) is a commonly used marker of lipid peroxidation in oxidative stress. To provide a sensitive analytical method that is compatible with high throughput, we developed a multiple reaction monitoring-mass spectrometry (MRM-MS) approach using 3-nitrophenylhydrazine chemical derivatization, isotope-labeling, and liquid chromatography (LC) with electrospray ionization (ESI)-tandem mass spectrometry assay to accurately quantify MDA in human plasma. A stable isotope-labeled internal standard was used to compensate for ESI matrix effects. The assay is linear (R(2)=0.9999) over a 20,000-fold concentration range with a lower limit of quantitation of 30fmol (on-column). Intra- and inter-run coefficients of variation (CVs) were 36h at 5°C. Standards spiked into plasma had recoveries of 92-98%. When compared to a common LC-UV method, the LC-MS method found near-identical MDA concentrations. A pilot project to quantify MDA in patient plasma samples (n=26) in a study of major depressive disorder with winter-type seasonal pattern (MDD-s) confirmed known associations between MDA concentrations and obesity (p<0.02). The LC-MS method provides high sensitivity and high reproducibility for quantifying MDA in human plasma. The simple sample preparation and rapid analysis time (5x faster than LC-UV) offers high throughput for large-scale clinical applications. PMID:27437618

  3. Fast quantification of endogenous carbohydrates in plasma using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry.

    Science.gov (United States)

    Zhu, Bangjie; Liu, Feng; Li, Xituo; Wang, Yan; Gu, Xue; Dai, Jieyu; Wang, Guiming; Cheng, Yu; Yan, Chao

    2015-01-01

    Endogenous carbohydrates in biosamples are frequently highlighted as the most differential metabolites in many metabolomics studies. A simple, fast, simultaneous quantitative method for 16 endogenous carbohydrates in plasma has been developed using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry. In order to quantify 16 endogenous carbohydrates in plasma, various conditions, including columns, chromatographic conditions, mass spectrometry conditions, and plasma preparation methods, were investigated. Different conditions in this quantified analysis were performed and optimized. The reproducibility, precision, recovery, matrix effect, and stability of the method were verified. The results indicated that a methanol/acetonitrile (50:50, v/v) mixture could effectively and reproducibly precipitate rat plasma proteins. Cold organic solvents coupled with vortex for 1 min and incubated at -20°C for 20 min were the most optimal conditions for protein precipitation and extraction. The results, according to the linearity, recovery, precision, matrix effect, and stability, showed that the method was satisfactory in the quantification of endogenous carbohydrates in rat plasma. The quantified analysis of endogenous carbohydrates in rat plasma performed excellently in terms of sensitivity, high throughput, and simple sample preparation, which met the requirement of quantification in specific expanded metabolomic studies after the global metabolic profiling research.

  4. Combining metal oxide affinity chromatography (MOAC and selective mass spectrometry for robust identification of in vivo protein phosphorylation sites

    Directory of Open Access Journals (Sweden)

    Weckwerth Wolfram

    2005-11-01

    Full Text Available Abstract Background Protein phosphorylation is accepted as a major regulatory pathway in plants. More than 1000 protein kinases are predicted in the Arabidopsis proteome, however, only a few studies look systematically for in vivo protein phosphorylation sites. Owing to the low stoichiometry and low abundance of phosphorylated proteins, phosphorylation site identification using mass spectrometry imposes difficulties. Moreover, the often observed poor quality of mass spectra derived from phosphopeptides results frequently in uncertain database hits. Thus, several lines of evidence have to be combined for a precise phosphorylation site identification strategy. Results Here, a strategy is presented that combines enrichment of phosphoproteins using a technique termed metaloxide affinity chromatography (MOAC and selective ion trap mass spectrometry. The complete approach involves (i enrichment of proteins with low phosphorylation stoichiometry out of complex mixtures using MOAC, (ii gel separation and detection of phosphorylation using specific fluorescence staining (confirmation of enrichment, (iii identification of phosphoprotein candidates out of the SDS-PAGE using liquid chromatography coupled to mass spectrometry, and (iv identification of phosphorylation sites of these enriched proteins using automatic detection of H3PO4 neutral loss peaks and data-dependent MS3-fragmentation of the corresponding MS2-fragment. The utility of this approach is demonstrated by the identification of phosphorylation sites in Arabidopsis thaliana seed proteins. Regulatory importance of the identified sites is indicated by conservation of the detected sites in gene families such as ribosomal proteins and sterol dehydrogenases. To demonstrate further the wide applicability of MOAC, phosphoproteins were enriched from Chlamydomonas reinhardtii cell cultures. Conclusion A novel phosphoprotein enrichment procedure MOAC was applied to seed proteins of A. thaliana and to

  5. Methods of Analysis - Determination of Pyrethroid Insecticides in Water and Sediment Using Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Hladik, Michelle L.; Smalling, Kelly L.; Kuivila, Kathryn M.

    2009-01-01

    A method for the determination of 14 pyrethroid insecticides in environmental water and sediment samples is described. The method was developed by the U.S. Geological Survey in response to increasing concern over the effects of pyrethroids on aquatic organisms. The pyrethroids included in this method are ones that are applied to many agricultural and urban areas. Filtered water samples are extracted for pyrethroids using solid-phase extraction (SPE) with no additional cleanup steps. Sediment and soil samples are extracted using a microwave-assisted extraction system, and the pyrethroids of interest are separated from co-extracted matrix interferences by passing the extracts through stacked graphitized carbon and alumina SPE cartridges, along with the use of high-performance liquid chromatography and gel-permeation chromatography (HPLC/GPC). Quantification of the pyrethroids from the extracted water and sediment samples is done using gas chromatography with mass spectrometry (GC/MS) or gas chromatography with tandem mass spectrometry (GC/MS/MS). Recoveries in test water samples fortified at 10 ng/L ranged from 83 to 107 percent, and recoveries in test sediment samples fortified at 10 ug/kg ranged from 82 to 101 percent; relative standard deviations ranged from 5 to 9 percent in the water samples and 3 to 9 percent in the sediment samples. Method detection limits (MDLs), calculated using U.S. Environmental Protection Agency procedures (40 CFR 136, Appendix B), in water ranged from 2.0 to 6.0 ng/L using GC/MS and 0.5 to 1.0 ng/L using GC/MS/MS. For sediment, the MDLs ranged from 1.0 to 2.6 ug/kg dry weight using GC/MS and 0.2 to 0.5 ug/kg dry weight using GC/MS/MS. The matrix-spike recoveries for each compound, when averaged for 12 environmental water samples, ranged from 84 to 96 percent, and when averaged for 27 environmental sediment samples, ranged from 88 to 100 percent.

  6. Analysis of perchlorate, thiocyanate, nitrate and iodide in human amniotic fluid using ion chromatography and electrospray tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Blount, Benjamin C. [Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341 (United States)]. E-mail: bblount@cdc.gov; Valentin-Blasini, Liza [Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341 (United States)

    2006-05-10

    Because of health concerns surrounding in utero exposure to perchlorate, we developed a sensitive and selective method for quantifying iodide, as well as perchlorate and other sodium-iodide symporter (NIS) inhibitors in human amniotic fluid using ion chromatography coupled with electrospray ionization tandem mass spectrometry. Iodide and NIS inhibitors were quantified using a stable isotope-labeled internal standards (Cl{sup 18}O{sub 4} {sup -}, S{sup 13}CN{sup -} and {sup 15}NO{sub 3} {sup -} with excellent assay accuracy of 100%, 98%, 99%, 95% for perchlorate, thiocyanate, nitrate and iodide, respectively, in triplicate analysis of spiked amniotic fluid sample). Excellent analytical precision (<5.2% RSD for all analytes) was found when amniotic fluid quality control pools were repetitively analyzed for iodide and NIS-inhibitors. Selective chromatography and tandem mass spectrometry reduced the need for sample cleanup, resulting in a rugged and rapid method capable of routinely analyzing 75 samples/day. Analytical response was linear across the physiologically relevant concentration range for the analytes. Analysis of a set of 48 amniotic fluid samples identified the range and median levels for perchlorate (0.057-0.71, 0.18 {mu}g/L), thiocyanate (<10-5860, 89 {mu}g/L), nitrate (650-8900, 1620 {mu}g/L) and iodide (1.7-170, 8.1 {mu}g/L). This selective, sensitive, and rapid method will help assess exposure of the developing fetus to low levels of NIS-inhibitors and their potential to inhibit thyroid function.

  7. Determination of amphetamine-type stimulants in oral fluid by solid-phase microextraction and gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Daniele Z., E-mail: daniele.dzs@dpf.gov.br [Setor Tecnico-Cientifico, Superintendencia Regional do Departamento de Policia Federal no Rio Grande do Sul, 1365 Ipiranga Avenue, Azenha, Zip Code 90160-093 Porto Alegre, Rio Grande do Sul (Brazil); Programa de Pos-Graduacao em Ciencias Farmaceuticas, Faculdade de Farmacia, Universidade Federal do Rio Grande do Sul, 2752 Ipiranga Avenue, Santana, Zip Code 90610-000 Porto Alegre, Rio Grande do Sul (Brazil); Boehl, Paula O.; Comiran, Eloisa; Mariotti, Kristiane C. [Programa de Pos-Graduacao em Ciencias Farmaceuticas, Faculdade de Farmacia, Universidade Federal do Rio Grande do Sul, 2752 Ipiranga Avenue, Santana, Zip Code 90610-000 Porto Alegre, Rio Grande do Sul (Brazil); Pechansky, Flavio [Centro de Pesquisa em Alcool e Drogas (CPAD), Hospital de Clinicas de Porto Alegre, Universidade Federal do Rio Grande do Sul, 2350, Ramiro Barcelos Street, Zip Code 90035-903 Porto Alegre, Rio Grande do Sul (Brazil); Duarte, Paulina C.A.V. [Secretaria Nacional de Politicas sobre Drogas (SENAD), Esplanada dos Ministerios, Block ' A' , 5th floor, Zip Code 70050-907 Brasilia, Distrito Federal (Brazil); De Boni, Raquel [Centro de Pesquisa em Alcool e Drogas (CPAD), Hospital de Clinicas de Porto Alegre, Universidade Federal do Rio Grande do Sul, 2350, Ramiro Barcelos Street, Zip Code 90035-903 Porto Alegre, Rio Grande do Sul (Brazil); Froehlich, Pedro E.; Limberger, Renata P. [Programa de Pos-Graduacao em Ciencias Farmaceuticas, Faculdade de Farmacia, Universidade Federal do Rio Grande do Sul, 2752 Ipiranga Avenue, Santana, Zip Code 90610-000 Porto Alegre, Rio Grande do Sul (Brazil)

    2011-06-24

    Graphical abstract: Highlights: > Propylchloroformate derivatization of amphetamine-type stimulants in oral fluid. > Direct immersion solid-phase microextraction/gas chromatography-mass spectrometry. > Linear range 2(4)-256 ng mL{sup -1}, detection limits 0.5-2 ng mL{sup -1}. > Accuracy 98-112%, precision <15% of RSD, recovery 77-112%. > Importance of residual evaluation in checking model goodness-of-fit. - Abstract: A method for the simultaneous identification and quantification of amphetamine (AMP), methamphetamine (MET), fenproporex (FEN), diethylpropion (DIE) and methylphenidate (MPH) in oral fluid collected with Quantisal{sup TM} device has been developed and validated. Thereunto, in-matrix propylchloroformate derivatization followed by direct immersion solid-phase microextraction and gas chromatography-mass spectrometry were employed. Deuterium labeled AMP was used as internal standard for all the stimulants and analysis was performed using the selected ion monitoring mode. The detector response was linear for the studied drugs in the concentration range of 2-256 ng mL{sup -1} (neat oral fluid), except for FEN, whereas the linear range was 4-256 ng mL{sup -1}. The detection limits were 0.5 ng mL{sup -1} (MET), 1 ng mL{sup -1} (MPH) and 2 ng mL{sup -1} (DIE, AMP, FEN), respectively. Accuracy of quality control samples remained within 98.2-111.9% of the target concentrations, while precision has not exceeded 15% of the relative standard deviation. Recoveries with Quantisal{sup TM} device ranged from 77.2% to 112.1%. Also, the goodness-of-fit concerning the ordinary least squares model in the statistical inference of data has been tested through residual plotting and ANOVA. The validated method can be easily automated and then used for screening and confirmation of amphetamine-type stimulants in drivers' oral fluid.

  8. Environmental analysis of alcohol ethoxylates and nonylphenol ethoxylate metabolites by ultra-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lara-Martín, Pablo A; González-Mazo, Eduardo; Brownawell, Bruce J

    2012-03-01

    Surfactants and their metabolites can be found in aquatic environments at relatively high concentrations compared with other micropollutants due in part to the exceptionally large volumes produced every year. We have focused our attention here on the most widely used nonionic surfactants, alcohol ethoxylates (AEOs), and on nonylphenol ethoxylate (NPEO) degradation products (short-chain nonylphenol ethoxylates, NP1-3EO, nonylphenol, NP, and nonylphenol ethoxycarboxylates, NP1-2EC), which are endocrine-disrupting compounds. Our main objective in this work was to develop a methodology aimed at the extraction, isolation, and improved analysis of these analytes in environmental samples at trace levels. Extraction recoveries of target compounds were determined for sediment samples after ultrasonic extraction and purification using HLB or C18 solid-phase extraction minicolumns. Recovery percentages were usually between 61 and 102% but were lower for longer AEO ethoxymers. Identification and quantification of target compounds was carried out using a novel ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS-MS) approach, a combination that provides higher sensitivity and faster analysis than prior methods using conventional high-performance liquid chromatography-mass spectrometry. Limits of detection were usually below 0.5 ng/g, being higher for monoethoxylate species (>5 ng/g) because of poor ionization. The method was used for analyzing surface sediment samples collected at Jamaica Bay (NY) in 2008. The highest values (28,500 ng/g for NP, 4,200 ng/g for NP1-3EO, 22,400 ng/g for NP1-2EC, and 1,500 ng/g for AEOs) were found in a sampling station from a restricted water circulation area that is heavily impacted by wastewater discharges. PMID:22002557

  9. Liquid chromatography quadrupole linear ion trap mass spectrometry for multiclass screening and identification of lipophilic marine biotoxins in bivalve mollusks.

    Science.gov (United States)

    Wu, Haiyan; Guo, Mengmeng; Tan, Zhijun; Cheng, Haiyan; Li, Zhaoxin; Zhai, Yuxiu

    2014-09-01

    A liquid chromatography quadrupole linear ion trap mass spectrometry method with fast polarity switching and a scheduled multiple reaction monitoring algorithm mode was developed for multiclass screening and identification of lipophilic marine biotoxins in bivalve molluscs. A major advantage of the method is that it can detect members of all six groups of lipophilic marine biotoxins [okadaic acid (OA), yessotoxins (YTX), azaspiracids (AZA), pectenotoxins (PTX), cyclic imines (CI), and brevetoxins (PbTx)], thereby allowing quantification and high confidence identification from a single liquid chromatography tandem mass spectrometry (LC-MS/MS) injection. An enhanced product ion (EPI) library was constructed after triggered collection of data via information-dependent acquisition (IDA) of EPI spectra from standard samples. A separation method for identifying 17 target toxins in a single analysis within 12min was developed and tested. Different solid phase extraction sorbents, the matrix effect (for oyster, scallop, and mussel samples), and stability of the standards also were evaluated. Matrix-matched calibration was used for quantification of the toxins. The limits of detection were 0.12-13.6μg/kg, and the limits of quantification were 0.39-45.4μg/kg. The method was used to analyze 120 shellfish samples collected from farming areas along the coast of China, and 7% of the samples were found to be contaminated with toxins. The library search identified PbTx-3, YTX, OA, PTX2, AZA1, AZA2, and desmethylspirolide C (SPX1). Overall, the method exhibited excellent sensitivity and reproducibility, and it will have broad applications in the monitoring of lipophilic marine biotoxins.

  10. Liquid chromatography quadrupole linear ion trap mass spectrometry for multiclass screening and identification of lipophilic marine biotoxins in bivalve mollusks.

    Science.gov (United States)

    Wu, Haiyan; Guo, Mengmeng; Tan, Zhijun; Cheng, Haiyan; Li, Zhaoxin; Zhai, Yuxiu

    2014-09-01

    A liquid chromatography quadrupole linear ion trap mass spectrometry method with fast polarity switching and a scheduled multiple reaction monitoring algorithm mode was developed for multiclass screening and identification of lipophilic marine biotoxins in bivalve molluscs. A major advantage of the method is that it can detect members of all six groups of lipophilic marine biotoxins [okadaic acid (OA), yessotoxins (YTX), azaspiracids (AZA), pectenotoxins (PTX), cyclic imines (CI), and brevetoxins (PbTx)], thereby allowing quantification and high confidence identification from a single liquid chromatography tandem mass spectrometry (LC-MS/MS) injection. An enhanced product ion (EPI) library was constructed after triggered collection of data via information-dependent acquisition (IDA) of EPI spectra from standard samples. A separation method for identifying 17 target toxins in a single analysis within 12min was developed and tested. Different solid phase extraction sorbents, the matrix effect (for oyster, scallop, and mussel samples), and stability of the standards also were evaluated. Matrix-matched calibration was used for quantification of the toxins. The limits of detection were 0.12-13.6μg/kg, and the limits of quantification were 0.39-45.4μg/kg. The method was used to analyze 120 shellfish samples collected from farming areas along the coast of China, and 7% of the samples were found to be contaminated with toxins. The library search identified PbTx-3, YTX, OA, PTX2, AZA1, AZA2, and desmethylspirolide C (SPX1). Overall, the method exhibited excellent sensitivity and reproducibility, and it will have broad applications in the monitoring of lipophilic marine biotoxins. PMID:25086754

  11. Trace analysis of acrylamide by high-performance thin-layer chromatography coupled to mass spectrometry

    OpenAIRE

    Alpmann, Alexander

    2011-01-01

    Planar-chromatography (High-Performance Thin-Layer Chromatography, HPTLC) is a rapid and cost-effective offline separation method. Through advances in the automatization of each step the system reproducibility, from application and development to detection, has been improved. This makes planar-chromatography a highly reliable technique. HPTLC shows a couple of features that make it unique. There is great flexibility concerning application, development and detection that distinguishes HPTLC fr...

  12. Pharmacokinetic studies of novel berberine derivatives with ultra-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Wang, Wenchao; Shen, Qin; Liang, Hui; Hua, Changlong; Liu, Yuhui; Li, Fengzhi; Li, Qingyong

    2016-09-15

    An ultra-performance liquid chromatography with tandem mass spectrometric detection method was developed for the detection of berberine and its derivatives (A4, B4) in rat plasma and other organs. This validated method was successfully applied to our pharmacokinetic study of BBR derivatives in rats. At the same dose of administration, the Cmax of B4 was about eight times higher than BBR, and its half-life was approximately two times longer than BBR, according to the bigger areas under plasma concentration curves. Inversely, the pharmacokinetic parameter levels of A4 were all inferior to BBR, suggesting a tight structure-activity relationship of these compounds. Small dose of parenteral administration was used for the study of absolute oral bioavailability of A4, B4, and BBR, and the results calculated were 0.12%, 3.4% and 0.7%, respectively. The accumulations of B4 among all organs were intestine>liver>heart>kidney>lung>spleen>plasma, proving a deeply targeting property of B4, which met our experimental assumption. Together, the experimental results proved that compared with BBR and A4, the derivative B4 had higher absolute oral bioavailability and the ability of deeply targeting so that can be likely used in some organ-targeted diseases. PMID:27494281

  13. Determination of homocitrulline in urine of patients with HHH syndrome by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Al-Dirbashi, Osama Y; Al-Hassnan, Zuhair N; Rashed, Mohamed S

    2006-12-01

    A liquid chromatography tandem mass spectrometric method is described for the analysis of homocitrulline in human urine, a key metabolite in the differential diagnosis of hyperammonemia, hyperornithinemia, homocitrullinuria (HHH) syndrome. Urine samples were prepared by mere five-fold dilution with a mixture of internal standards (2H2-citrulline and 2H3-creatinine) used for the simultaneous quantification of creatinine. Analytes were separated on a cyano column and eluted isocratically within seven min. Detection was achieved by monitoring transitions of 190 > 84 and 190 > 127 for homocitrulline, 178 > 115 for 2H2-citrulline, 114 > 44 for creatinine and 117 > 47 for 2H3-creatinine. Calibration curves were linear up to 100 micromol/L. Intraday (n = 7) and interday (n = 6) variations were less than 10%. In urine samples from three siblings confirmed to have HHH syndrome, homocitrulline levels were at 13.3 (74), 21.1 (50) and 108.2 (103) mmol/mol creatinine (micromol/L). Control values were 0-9 mmol/mol creatinine (n = 120). The current method solves specificity issues in homocitrulline determination often encountered with some ninhydrin-based systems (coelution with methionine) and some o-phthalaldehyde-based ones (coelution with taurine), and presents an attractive alternative with a relatively high throughput.

  14. Multiresidue Analysis of 86 Pesticides Using Gas Chromatography Mass Spectrometry: II-Nonleafy Vegetables

    Directory of Open Access Journals (Sweden)

    M. H. EL-Saeid

    2013-01-01

    Full Text Available A total of 1057 samples of fresh vegetables from import and domestic production were analyzed (cold pepper, egg plant, carrot, cucumber, potato, hot pepper, cultivation tomato, squash, beans, okra, onions, cauliflower, and green house tomato. The aim of this study was to investigate pesticide residues in market foods in Riyadh, which have been collected from Riyadh Development Company (Al-Tamer Vegetables Market. Pesticide residues were determined by gas chromatography with mass selective detector (GC-MSD. A multiresidue method was developed and described for simultaneous determination of 86 pesticides commonly used in crop protection. This method used to determine 86 pesticide residues with a broad range of physicochemical properties in fresh vegetables related to organophosphorus (OPP, organochlorines (OCP, pyrethroids, and carbamates mainly used in agriculture. Sample extract was cleaned up by using AOAC method. Pesticide residues above the maximum residue limits (MRL were detected in 15.89% of the total samples (168 from 1057 samples, but 83.90% of the total samples (887 from 1057 samples has no residues or contained pesticide residues at or below MRL. The detected and most frequently found pesticide residues were permethrin (45 times and endosulfan (34 times followed by deltamethrin (27 times. The findings of this study pointed to the following recommendations: the need for a monitoring program for pesticide residues in imported food crops.

  15. Determination of gestagens in kidney fat by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Lõhmus, Madis; Kender, Tiia

    2007-03-14

    The use of gestagens in animal fattening is prohibited within the European Union. Recently, the use of spectrometric methods for the detection and confirmation of banned substances was made obligatory. Therefore, conventional high-performance liquid chromatographic (HPLC) methods have been superseded. It has been possible to couple a previously described HPLC method for the determination of acetyl-gestagens in kidney fat to tandem mass spectrometry (LC-MS/MS). The decision limits CCalpha and the detection capability CCbeta are found to be below the minimum required performance limit (MRPL) established for medroxyprogesterone acetate (MPA) at 1 microg kg(-1). The calculated values for CCalpha are as follows: megestrol acetate (MGA)--0.15 microg kg(-1), melengesterol acetate (MLA)--0.15 microg kg(-1), chlormadinone acetate (CMA)--0.37 microg kg(-1) and for medroxyprogesterone acetate (MPA)--0.24 microg kg(-1). The CCbeta values for these compounds have been determined as 0.19, 0.19, 0.47 and 0.32 microg kg(-1), respectively. PMID:17386717

  16. [Qualitative and quantitative analysis of amygdalin and its metabolite prunasin in plasma by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry].

    Science.gov (United States)

    Gao, Meng; Wang, Yuesheng; Wei, Huizhen; Ouyang, Hui; He, Mingzhen; Zeng, Lianqing; Shen, Fengyun; Guo, Qiang; Rao, Yi

    2014-06-01

    A method was developed for the determination of amygdalin and its metabolite prunasin in rat plasma after intragastric administration of Maxing shigan decoction. The analytes were identified by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and quantitatively determined by ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry. After purified by liquid-liquid extraction, the qualitative analysis of amygdalin and prunasin in the plasma sample was performed on a Shim-pack XR-ODS III HPLC column (75 mm x 2.0 mm, 1.6 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on a Triple TOF 5600 quadrupole time of flight mass spectrometer. The quantitative analysis of amygdalin and prunasin in the plasma sample was performed by separation on an Agilent C18 HPLC column (50 mm x 2.1 mm, 1.7 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on an AB Q-TRAP 4500 triple quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operated in negative ion mode and multiple-reaction monitoring (MRM) mode. The qualitative analysis results showed that amygdalin and its metabolite prunasin were detected in the plasma sample. The quantitative analysis results showed that the linear range of amygdalin was 1.05-4 200 ng/mL with the correlation coefficient of 0.999 0 and the linear range of prunasin was 1.25-2 490 ng/mL with the correlation coefficient of 0.997 0. The method had a good precision with the relative standard deviations (RSDs) lower than 9.20% and the overall recoveries varied from 82.33% to 95.25%. The limits of detection (LODs) of amygdalin and prunasin were 0.50 ng/mL. With good reproducibility, the method is simple, fast and effective for the qualitative and quantitative analysis of the amygdalin and prunasin in plasma sample of rats which were administered by Maxing shigan decoction.

  17. Determination of membrane degradation products in the product water of polymer electrolyte membrane fuel cells using liquid chromatography mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zedda, Marco

    2011-05-12

    The predominant long term failure of polymer electrolyte membranes (PEM) is caused by hydroxyl radicals generated during fuel cell operation. These radicals attack the polymer, leading to chain scission, unzipping and consequently to membrane decomposition products. The present work has investigated decomposition products of novel sulfonated aromatic hydrocarbon membranes on the basis of a product water analysis. Degradation products from the investigated membrane type and the possibility to detect these compounds in the product water for diagnostic purposes have not been discovered yet. This thesis demonstrates the potential of solid phase extraction and liquid chromatography tandem mass spectrometry (SPE-LC-MS/MS) for the extraction, separation, characterization, identification and quantification of membrane degradation products in the product water of fuel cells. For this purpose, several polar aromatic hydrocarbons with different functional groups were selected as model compounds for the development of reliable extraction, separation and detection methods. The results of this thesis have shown that mixed mode sorbent materials with both weak anion exchange and reversed phase retention properties are well suited for reproducible extraction of both molecules and ions from the product water. The chromatographic separation of various polar aromatic hydrocarbons was achieved by means of phase optimized liquid chromatography using a solvent gradient and on a C18 stationary phase. Sensitive and selective detection of model compounds could be successfully demonstrated by the analysis of the product water using tandem mass spectrometry. The application of a hybrid mass spectrometer (Q Trap) for the characterization of unknown polar aromatic hydrocarbons has led to the identification and confirmation of 4-hydroxybenzoic acid in the product water. In addition, 4-HBA could be verified as a degradation product resulting from PEM decomposition by hydroxyl radicals using an

  18. New method for caffeine quantification by planar chromatography coupled with electropray ionization mass spectrometry using stable isotope dilution analysis.

    Science.gov (United States)

    Aranda, Mario; Morlock, Gertrud

    2007-01-01

    A new high-performance thin-layer chromatography/electrospray ionization mass spectrometry (HPTLC/ESI-MS) method for the quantification of caffeine in pharmaceutical and energy drink samples was developed using stable isotope dilution analysis (SIDA). After sample preparation, samples and caffeine standard were applied on silica gel 60 F254 HPTLC plates and over-spotted with caffeine-d3 used for correction of the plunger positioning. After chromatography, densitometric detection was performed by UV absorption at 274 nm. The bands were then eluted by means of a plunger-based extractor into the ESI interface of a single-quadrupole mass spectrometer. For quantification by MS the [M+H]+ ions of caffeine and caffeine-d3 were recorded in the positive ion single ion monitoring (SIM) mode at m/z 195 and 198, respectively. The calibration showed a linear regression with a determination coefficient (R2) of 0.9998. The repeatability (RSD, n=6) in matrix wasbrand names were determined three times and ranged between RSD+/-0.68% and+/-2.64% (sample 1) and between+/-3.44% and+/-8.60% (sample 2). The method accuracy was evaluated by comparing the results obtained by HPTLC/SIDA-ESI-MS with those from the validated HPTLC/UV method. The results for pharmaceutical and energy drink samples were (ng/band) 99.82+/-3.75 and 338.09+/-4.87 by HPTLC/SIDA-ESI-MS and 104.74+/-1.51 and 334.86+/-5.63 by HPTLC/UV. According to the F-test (homogeneity of variances) and the t-test (comparison of means) the two methods show no significant difference. The detection and quantification limits were 75 and 250 microg L-1 (0.75 and 2.5 ng/band), respectively, which were a factor of 13 lower than those established for HPTLC/UV. The positioning error (RSD+/-6%) was calculated by comparing HPTLC/SIDA-ESI-MS with HPTLC/ESI-MS. However, using SIDA the positioning error was nullified. HPTLC/SIDA-ESI-MS was demonstrated to be a highly reliable method for the quantification of compounds by planar chromatography

  19. Screening for exogenous androgen anabolic steroids in human hair by liquid chromatography/orbitrap-high resolution mass spectrometry.

    Science.gov (United States)

    Strano-Rossi, Sabina; Castrignanò, Erika; Anzillotti, Luca; Odoardi, Sara; De-Giorgio, Fabio; Bermejo, Ana; Pascali, Vincenzo L

    2013-09-01

    A method for the screening of various anabolic steroids and their esters in human hair, based on liquid-chromatography-high resolution mass spectrometry using an Exactive benchtop Orbitrap mass spectrometer, has been set up and validated. This method involved methanolic incubation of 30 mg of hair and analysis of the relevant extract in HPLC using a C18 column. The mass detector, with nominal resolving power of 100,000, operated in full scan mode in APCI under positive ionization mode. Analytes were identified by exact mass, correspondence of isotopic cluster and retention times. The limits of detection obtained varied from 10 to 50 pg mg(-1), and limits of quantitation were 0.5 ng mg(-1) for all compounds. The method was linear for all analytes in the ranges from the LOQ to 6 ng mg(-1), giving correlation coefficients >0.99 for all analytes. Also accuracy (intended as %E) and repeatability (%CV) were always lower than 15%. Specificity was assessed by analysing ten blank samples and fifteen samples from polidrug abusers. This method was applied to a real-life case, resulting in the identification of testosterone undecanoate in the hair of a suspect. The analyte identity was confirmed by the analysis of its in-source fragmentation and comparison to a certified standard. Thanks to the scan acquisition, this method also enables retrospective re-analysis of the acquired datafile in case a further analyte needs to be screened. PMID:23953207

  20. Gas Chromatography Coupled to Atmospheric Pressure Chemical Ionization FT-ICR Mass Spectrometry for Improvement of Data Reliability.

    Science.gov (United States)

    Schwemer, Theo; Rüger, Christopher P; Sklorz, Martin; Zimmermann, Ralf

    2015-12-15

    Atmospheric pressure chemical ionization (APCI) offers the advantage of molecular ion information with low fragmentation. Hyphenating APCI to gas chromatography (GC) and ultrahigh resolution mass spectrometry (FT-ICR MS) enables an improved characterization of complex mixtures. Data amounts acquired by this system are very huge, and existing peak picking algorithms are usually extremely time-consuming, if both gas chromatographic and ultrahigh resolution mass spectrometric data are concerned. Therefore, automatic routines are developed that are capable of handling these data sets and further allow the identification and removal of known ionization artifacts (e.g., water- and oxygen-adducts, demethylation, dehydrogenation, and decarboxylation). Furthermore, the data quality is enhanced by the prediction of an estimated retention index, which is calculated simply from exact mass data combined with a double bond equivalent correction. This retention index is used to identify mismatched elemental compositions. The approach was successfully tested for analysis of semivolatile components in heavy fuel oil and diesel fuel as well as primary combustion particles emitted by a ship diesel research engine. As a result, 10-28% of the detected compounds, mainly low abundant species, classically assigned by using only the mass spectrometric information, were identified as not valid and removed. Although GC separation is limited by the slow acquisition rate of the FT-ICR MS (information.