WorldWideScience

Sample records for chromatography isotope dilution

  1. Isotope-Dilution Mass Spectrometry for Quantification of Urinary Active Androgens Separated by Gas Chromatography

    OpenAIRE

    Su Hyeon Lee; Man Ho Choi; Won-Yong Lee; Bong Chul Chung

    2010-01-01

    Cross reacting antibodies can cause an overestimation of the results of immunoassays. Therefore, alternative methodsare needed for the accurate quantification of steroids. Gas chromatography combined with isotope-dilution mass spectrometry(GC-IDMS) is developed to quantify urinary active androgens, testosterone, epitestosterone and dihydrotestosterone, which areclinically relevant androgens to both hair-loss and prostate diseases. The method devised involves enzymatic hydrolysis with β-glucur...

  2. Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Douglas C., E-mail: douglas.baxter@alsglobal.com [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Faarinen, Mikko [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Osterlund, Helene; Rodushkin, Ilia [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Division of Geosciences, Lulea University of Technology, 977 87 Lulea (Sweden); Christensen, Morten [ALS Scandinavia AB, Maskinvaegen 2, 183 53 Taeby (Sweden)

    2011-09-09

    Highlights: {center_dot} We determine methylmercury in serum and plasma using isotope dilution calibration. {center_dot} Separation by gas chromatography and detection by inductively coupled plasma mass spectrometry. {center_dot} Data for 50 specimens provides first reference range for methylmercury in serum. {center_dot} Serum samples shown to be stable for 11 months in refrigerator. - Abstract: A method for the determination of methylmercury in plasma and serum samples was developed. The method uses isotope dilution with {sup 198}Hg-labeled methylmercury, extraction into dichloromethane, back-extraction into water, aqueous-phase ethylation, purge and trap collection, thermal desorption, separation by gas chromatography, and mercury isotope specific detection by inductively coupled plasma mass spectrometry. By spiking 2 mL sample with 1.2 ng tracer, measurements in a concentration interval of (0.007-2.9) {mu}g L{sup -1} could be performed with uncertainty amplification factors <2. A limit of quantification of 0.03 {mu}g L{sup -1} was estimated at 10 times the standard deviation of concentrations measured in preparation blanks. Within- and between-run relative standard deviations were <10% at added concentration levels of 0.14 {mu}g L{sup -1}, 0.35 {mu}g L{sup -1} and 2.8 {mu}g L{sup -1}, with recoveries in the range 82-110%. Application of the method to 50 plasma/serum samples yielded a median (mean; range) concentration of methylmercury of 0.081 (0.091; <0.03-0.19) {mu}g L{sup -1}. This is the first time methylmercury has been directly measured in this kind of specimen, and is therefore the first estimate of a reference range.

  3. Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Baxter, Douglas C; Faarinen, Mikko; Österlund, Heléne; Rodushkin, Ilia; Christensen, Morten

    2011-09-01

    A method for the determination of methylmercury in plasma and serum samples was developed. The method uses isotope dilution with (198)Hg-labeled methylmercury, extraction into dichloromethane, back-extraction into water, aqueous-phase ethylation, purge and trap collection, thermal desorption, separation by gas chromatography, and mercury isotope specific detection by inductively coupled plasma mass spectrometry. By spiking 2 mL sample with 1.2 ng tracer, measurements in a concentration interval of (0.007-2.9) μg L(-1) could be performed with uncertainty amplification factors levels of 0.14 μg L(-1), 0.35 μg L(-1) and 2.8 μg L(-1), with recoveries in the range 82-110%. Application of the method to 50 plasma/serum samples yielded a median (mean; range) concentration of methylmercury of 0.081 (0.091; methylmercury has been directly measured in this kind of specimen, and is therefore the first estimate of a reference range.

  4. Quantitation of Thioprolines in Grape Wine by Isotope Dilution-Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Liu, Jingjing; Meng, Xiangpeng; Chan, Wan

    2016-02-17

    Cysteine reacts with reactive carbonyls to form thioprolines, which have been demonstrated to possess various pharmaceutical properties. Therefore, thioproline formation is considered as a major detoxification pathway for carcinogenic reactive carbonyls. In this study, we report the initial identification of thiazolidine-4-carboxylic acid (1) and 2-methylthiazolidine-4-carboxylic acid (2), two very common thioprolines, formed by reacting formaldehyde and acetaldehyde with cysteine in grape wine samples. We have developed an isotope dilution-liquid chromatography-tandem mass spectrometry method featuring high sensitivity (limit of detection of ≤1.5 ng/mL) and selectivity to quantitate compounds 1 and 2. The method after validated to be highly accurate (recovery of ≥92%) and precise [intraday relative standard deviation (RSD) of ≤4.1% and interday RSD of ≤9.7%] was applied to determine the varying compound 1 and 2 contents in grape wine samples. Results revealed the grape type and storage duration-dependent formation of thioprolines in grape wines. Overall, the results are expected to facilitate compound-dependent investigations of the health benefits of grape wine, and our findings could be adopted to predict the age of grape wine.

  5. Development of hemoglobin A1c certified reference material by liquid chromatography isotope dilution mass spectrometry.

    Science.gov (United States)

    Bi, Jiaming; Wu, Liqing; Yang, Bin; Yang, Yi; Wang, Jing

    2012-04-01

    We report the development of a National Institute of Metrology (NIM) hemoglobin A(1c) (HbA(1c)) certified reference material (CRM). Each CRM unit contains about 10 μL of hemoglobin. Both hemoglobin and glycated hemoglobin were quantitatively determined by high-performance liquid chromatography (HPLC)-isotope dilution mass spectrometry (IDMS) with synthesized VHLTPE and glycated VHLTPE as standards. The mass fraction of synthesized VHLTPE or glycated VHLTPE was also quantitatively determined by HPLC-IDMS with NIM amino acid CRMs as standards. The homogeneity and stability of the CRMs were examined with a commercial HbA(1c) analyzer based on the HPLC principle. Fifteen units were randomly selected for homogeneity examination, and statistical analysis showed there was no inhomogeneity. Examination of the stability showed that the CRM was stable for at least 6 months at -80 °C. Uncertainty components of the balance, amino acid purity, hydrolysis and proteolysis efficiency, method reproducibility, homogeneity, and stability were taken into consideration for uncertainty evaluation. The certified value of NIM HbA(1c) CRM was expressed as the ratio of HbA(1c) to total hemoglobin in moles, and was (9.6 ± 1.9)%. The CRM can be used as a calibration or validation standard for clinical diagnostics. It is expected to improve the comparability for HbA(1c) measurement in China.

  6. Quantitation of organophosphorus nerve agent metabolites in human urine using isotope dilution gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Driskell, W Jack; Shih, Ming; Needham, Larry L; Barr, Dana B

    2002-01-01

    An isotope dilution gas chromatography-tandem mass spectrometric (GC-MS-MS) method was developed for quantitating the urinary metabolites of the organophosphorus nerve agents sarin, soman, tabun (GA), VX, and GF. Urine samples were concentrated by codistillation with acetonitrile, derivatized by methylation with diazomethane, and analyzed by GC-MS-MS. The limits of detection were less than 4 microg/L for all the analytes except for the GA metabolite, which had a limit of detection of less than 20 microg/L.

  7. Quantification of fentanyl in serum by isotope dilution analysis using capillary gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Sera, Shoji; Goromaru, Tsuyoshi [Fukuyama Univ., Hiroshima (Japan); Sameshima, Teruko; Kawasaki, Koichi; Oda, Toshiyuki

    1998-06-01

    The quantitative determination of fentanyl (FT) in serum was examined by isotope dilution analysis using a capillary gas chromatograph equipped with a surface ionization detector. The separation of FT and its deuterated analogue, FT-{sup 2}H{sub 19}, was achieved within 15 min a column temperature of 260degC by using a 25 m column. Measurement of the samples prepared by the addition of a known amount of FT in the range of 0.2 to 40 ng/ml with 20 ng/ml of FT-{sup 2}H{sub 19} to human control serum allowed observation of a linear relationship between the peak area ratio and the added amount ratio. The correlation coefficient obtained by regression analysis was 0.999. The advantage of the present isotope dilution method was demonstrated by comparison with other FT analogues which substituted a propionyl group with an acetyl group or a phenethyl group with a benzyl group as the internal standard. The present method was used to determine the serum level of FT in surgical patients after i.v. administration. No endogenous compounds and concomitant drugs interfered with the detection of FT or FT-{sup 2}H{sub 19}. This method was considered to be useful for the pharmacokinetic study of FT in patients. (author)

  8. Measurement of pyrethroid, organophosphorus, and carbamate insecticides in human plasma using isotope dilution gas chromatography-high resolution mass spectrometry.

    Science.gov (United States)

    Pérez, José J; Williams, Megan K; Weerasekera, Gayanga; Smith, Kimberly; Whyatt, Robin M; Needham, Larry L; Barr, Dana Boyd

    2010-10-01

    We have developed a gas chromatography-high resolution mass spectrometry method for measuring pyrethroid, organophosphorus, carbamate and fipronil pesticides and the synergist piperonyl butoxide in human plasma. Plasma samples were extracted using solid phase extraction and were then concentrated for injection and analysis using isotope dilution gas chromatography-high resolution mass spectrometry. The limits of detection ranged from 10 to 158 pg/mL with relative recoveries at concentrations near the LODs (e.g., 25 or 250 pg/mL) ranging from 87% to 156% (9 of the 16 compounds were within ±15% of 100%). The extraction recoveries ranged from 20% to 98% and the overall method relative standard deviations were typically less than 20% with some exceptions. Analytical characteristics were determined at 25, 250, and 1000 pg/mL.

  9. Simplified absolute metabolite quantification by gas chromatography-isotope dilution mass spectrometry on the basis of commercially available source material.

    Science.gov (United States)

    Vielhauer, Oliver; Zakhartsev, Maksim; Horn, Thomas; Takors, Ralf; Reuss, Matthias

    2011-12-15

    In the field of metabolomics, GC-MS has rather established itself as a tool for semi-quantitative strategies like metabolic fingerprinting or metabolic profiling. Absolute quantification of intra- or extracellular metabolites is nowadays mostly accomplished by application of diverse LC-MS techniques. Only few groups have so far adopted GC-MS technology for this exceptionally challenging task. Besides numerous and deeply investigated problems related to sample generation, the pronounced matrix effects in biological samples have led to the almost mandatory application of isotope dilution mass spectrometry (IDMS) for the accurate determination of absolute metabolite concentrations. Nevertheless, access to stable isotope labeled internal standards (ILIS), which are in many cases commercially unavailable, is quite laborious and very expensive. Here we present an improved and simplified gas chromatography-isotope dilution mass spectrometry (GC-IDMS) protocol for the absolute determination of intra- and extracellular metabolite levels. Commercially available (13)C-labeled algal cells were used as a convenient source for the preparation of internal standards. Advantages as well as limitations of the described method are discussed.

  10. Isotope dilution analysis for urinary fentanyl and its main metabolite, norfentanyl, in patients by isotopic fractionation using capillary gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Sera, Shoji; Goromaru, Tsuyoshi [Fukuyama Univ., Hiroshima (Japan). Faculty of Pharmacy and Pharmaceutical Sciences; Sameshima, Teruko; Kawasaki, Koichi; Oda, Toshiyuki

    1998-07-01

    Isotope dilution analysis was applied to determine urinary excretion of fentanyl (FT) and its main metabolite, norfentanyl (Nor-FT), by isotopic fractionation using a capillary gas chromatograph equipped with a surface ionization detector (SID). Urinary FT was determined quantitatively in the range of 0.4-40 ng/ml using deuterium labeled FT (FT-{sup 2}H{sub 19}), as an internal standard. We also performed isotope dilution analysis of Nor-FT in urine. N-Alkylation was necessary to sensitively detect Nor-FT with SID. Methyl derivative was selected from 3 kinds of N-alkyl derivatives to increase sensitivity and peak resolution, and to prevent interference with urinary compound. Nor-FT concentration was quantitatively determined in the range of 10-400 ng/ml using deuterium labeled Nor-FT (Nor-FT-{sup 2}H{sub 10}). No endogenous compounds or concomitant drugs interfered with the detection of FT and Nor-FT in the urine of patients. The present method will be useful for pharmacokinetic studies and the evaluation of drug interactions in FT metabolism. (author)

  11. Determination of benzene in soft drinks and other beverages by isotope dilution headspace gas chromatography/mass spectrometry.

    Science.gov (United States)

    Cao, Xu-Liang; Casey, Valerie; Seaman, Steve; Tague, Brett; Becalski, Adam

    2007-01-01

    An automated, simple, and reproducible method was developed for the determination of benzene in soft drinks, based on isotope dilution headspace gas chromatography/mass spectrometry in the selected-ion monitoring mode. The method was used to assess benzene levels in samples of 124 soft drinks and beverages. Benzene was not detected in 60% of the 124 products. The average benzene levels in 6 products exceeded the Canadian maximum acceptable concentration of 5 microg/L for benzene in drinking water, and 2 of the 6 products had benzene levels above the World Health Organization guideline of 10 microg/L. The highest level of benzene, 23 microg/L, was found in a soft drink product specifically marketed to children.

  12. Accurate determination of ochratoxin A in Korean fermented soybean paste by isotope dilution-liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Ahn, Seonghee; Lee, Suyoung; Lee, Joonhee; Kim, Byungjoo

    2016-01-01

    Ochratoxin A (OTA), a naturally occurring mycotoxin, has been frequently detected in doenjang, a traditional fermented soybean paste, when it is fermented under improper conditions. Reliable screening of OTA in traditional fermented soybean paste (doenjang) is a special food-safety issue in Korea. Our laboratory, the National Metrology Institute of Korea, established an isotope dilution-liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) method as a higher-order reference method to be used for SI-traceable value-assignment of OTA in certified reference materials (CRMs). (13)C20-OTA was used as an internal standard. Sample preparation conditions and LC/MS measurement parameters were optimised for this purpose. The analytical method was validated by measuring samples fortified with OTA at various levels. Repeatability and reproducibility studies showed that the ID-LC/MS/MS method is reliable and reproducible within 2% relative standard deviation. The analytical method was applied to determine OTA in various commercial doenjang products and home-made doenjang products.

  13. Determining mycotoxins in baby foods and animal feeds using stable isotope dilution and liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Kai; Wong, Jon W; Krynitsky, Alexander J; Trucksess, Mary W

    2014-09-10

    We developed a stable isotope dilution assay with liquid chromatography tandem mass spectrometry (LC-MS/MS) to determine multiple mycotoxins in baby foods and animal feeds. Samples were fortified with [(13)C]-uniformly labeled mycotoxins as internal standards ([(13)C]-IS) and prepared by solvent extraction (50% acetonitrile in water) and filtration, followed by LC-MS/MS analysis. Mycotoxins in each sample were quantitated with the corresponding [(13)C]-IS. In general, recoveries of aflatoxins (2-100 ng/g), deoxynivalenol, fumonisins (50-2000 ng/g), ochratoxin A (20-1000 ng/kg), T-2 toxin, and zearalenone (40-2000 ng/g) in tested matrices (grain/rice/oatmeal-based formula, animal feed, dry cat/dog food) ranged from 70 to 120% with relative standard deviations (RSDs) <20%. The method provides sufficient selectivity, sensitivity, accuracy, and reproducibility to screen for aflatoxins at ng/g concentrations and deoxynivalenol and fumonisins at low μg/g concentrations in baby foods and animal feeds, without using conventional standard addition or matrix-matched calibration standards to correct for matrix effects.

  14. Stable Isotope Dilution Analysis of Gibberellin Residues in Tomato Paste by Liquid Chromatography-Tandem Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    SUN Li; ZHAO Yan-sheng; NIE Xue-mei; LING Yun; CHU Xiao-gang; SHANG De-jun; DONG Ying

    2012-01-01

    An accurate and sensitive method for the simultaneous determination of gibberellic acid(GA3),gibberellin A4(GA4) and gibberellin A7(GA7) residues in tomato paste was developed by coupling solid phase extraction to high performance liquid chromatography-tandem mass spectrometry(LC-MS/MS) with electrospray ionization based stable isotope dilution analysis(SIDA).The isotope labeled internal standard can compensate for the losses during the extraction and cleanup steps and for discrimination due to ion suppression.After extraction from methanol,hydrophile lipophilic balance(HLB) solid phase extraction(SPE) column was tested for the capacity of the cleanup of the tomato paste in compared with C18 SPE column which is the common way to the detection of GAs,and the former gained better result.Spiked experiments were performed in the non-contaminated tomato pastes and the recoveries of GA3,GA4 and GA7 were 42.6%-75.0% in external standard method(ESM) and 91.1%-103.8% in internal standard method(ISM) respectively.The validities of this method were investigated and good analytical performance for the three GAs was obtained,including low limits of method detection(2 ng/g for GA3 and GA4,0.3 ng/g for GA7),excellent linear dynamic ranges(5-500 ng/g for GA3 and GA4,1-100 ng/g for GAy) and good relative standard deviation ranges(4.8%-9.4% for the intra-day test and 3.5%-11.9% for the inter-day test).

  15. Simultaneous detection of five one-carbon metabolites in plasma using stable isotope dilution liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Adaikalakoteswari, Antonysunil; Webster, Craig; Goljan, Ilona; Saravanan, Ponnusamy

    2016-02-15

    Disturbance in one-carbon (1-C) cycle occurs due to nutritional deficiencies (vitamin B12/folate) or specific genetic polymorphisms. This leads to altered levels of key 1-C metabolites such as SAM (s-adenosyl methionine), SAH (s-adenosyl homocysteine), methionine, homocysteine and MMA (methyl malonic acid). These 1-C metabolites are determinants of cellular methylation potential and epigenetic modifications of DNA which impairs metabolic pathways in several pathological diseases and developmental programming. Though methods were able to measure these analytes only independently, none of the methods detect simultaneously. Therefore we developed a method to measure these five 1-C metabolites in a single run using liquid chromatography tandem mass spectrometry (LC-MS/MS). We used stable isotopes dilution LC-MS/MS to measure the 1-C metabolites in human plasma. Blood samples were collected from pregnant women (n=30) at early gestation in the ongoing, multicentre, prospective PRiDE study. Linearity exhibited across the calibration range for all the analytes with the limit of detection (LOD) of 1.005nmol/l for SAM, 0.081nmol/l for SAH, 0.002μmol/l for methionine, 0.046μmol/l for homocysteine and 3.920nmol/l for MMA. The average recovery for SAM was 108%, SAH-110%, methionine-97%, homocysteine-91% and MMA-102%. The inter-assay CV for SAM was 7.3, SAH-5.6%, methionine-3.5%, homocysteine-7.0% and MMA-4.0%. The intra-assay CV for SAM was 8.7%, SAH-4.7%, methionine-5.4%, homocysteine-8.1% and MMA-6.1%. Pregnant women at early gestation with low B12 levels had significantly higher homocysteine, MMA, lower levels of methionine, SAM and SAM:SAH ratio and higher triglycerides. We developed a simple and rapid method to simultaneously quantify 1-C metabolites such as SAM, SAH, methionine, homocysteine and MMA in plasma by stable isotope dilution LC-MS/MS which would be useful to elucidate the epigenetic mechanisms related in the gene-nutrient interactions.

  16. Quantification of Influenza Neuraminidase Activity by Ultra-High Performance Liquid Chromatography and Isotope Dilution Mass Spectrometry.

    Science.gov (United States)

    Solano, Maria I; Woolfitt, Adrian R; Williams, Tracie L; Pierce, Carrie L; Gubareva, Larisa V; Mishin, Vasiliy; Barr, John R

    2017-03-07

    Mounting evidence suggests that neuraminidase's functionality extends beyond its classical role in influenza virus infection and that antineuraminidase antibodies offer protective immunity. Therefore, a renewed interest in the development of neuraminidase (NA)-specific methods to characterize the glycoprotein and evaluate potential advantages for NA standardization in influenza vaccines has emerged. NA displays sialidase activity by cleaving off the terminal N-acetylneuraminic acid on α-2,3 or α-2,6 sialic acid containing receptors of host cells. The type and distribution of these sialic acid containing receptors is considered to be an important factor in transmission efficiency of influenza viruses between and among host species. Changes in hemagglutinin (HA) binding and NA specificity in reassortant viruses may be related to the emergence of new and potentially dangerous strains of influenza. Current methods to investigate neuraminidase activity use small derivatized sugars that are poor models for natural glycoprotein receptors and do not provide information on the linkage specificity. Here, a novel approach for rapid and accurate quantification of influenza neuraminidase activity is achieved utilizing ultra-high performance liquid chromatography (UPLC) and isotope dilution mass spectrometry (IDMS). Direct LC-MS/MS quantification of NA-released sialic acid provides precise measurement of influenza neuraminidase activity over a range of substrates. The method provides exceptional sensitivity and specificity with a limit of detection of 0.38 μM for sialic acid and the capacity to obtain accurate measurements of specific enzyme activity preference toward α-2,3-sialyllactose linkages, α-2,6-sialyllactose linkages, or whole glycosylated proteins such as fetuin.

  17. Determination of urea kinetics by isotope dilution with [C-13]urea and gas chromatography isotope ratio mass spectrometry (GC-IRMS) analysis

    NARCIS (Netherlands)

    Kloppenburg, Wybe; Wolthers, BG; Stellaard, F; Elzinga, H; Tepper, T; deJong, PE; Huisman, RM

    1997-01-01

    1. Stable urea isotopes can be used to study urea kinetics in humans, The use of stable urea isotopes far studying urea kinetic parameters in humans on a large scale is hampered by the high costs of the labelled material, We devised a urea dilution for measurement of the distribution volume, product

  18. Determination of thyroid hormones in mouse tissues by isotope-dilution microflow liquid chromatography-mass spectrometry method.

    Science.gov (United States)

    De Angelis, Meri; Giesert, Florian; Finan, Brian; Clemmensen, Christoffer; Müller, Timo D; Vogt-Weisenhorn, Daniela; Tschöp, Matthias H; Schramm, Karl-Werner

    2016-10-15

    Thyroid hormones (THs) play a critical role in the regulation of many biological processes such as growth, metabolism and development both in humans and wildlife. In general, TH levels are measured by immunoassay (IA) methods but the specificity of the antibodies used in these assays limits selectivity. In the last decade, several analytical methods using liquid chromatography-mass spectrometry (LC-MS) and tandem mass spectrometry (LC-MS/MS) have been developed to measure THs. These new techniques proved to be more accurate than the IA analysis and they were widely used for the determination of TH level in different human and animal tissues. A large part of LC-MS/MS methods described in literature employed between 200 and 500mg of sample, however this quantity can be considered too high especially when preclinical studies are conducted using mice as test subjects. Thus an analytical method that reduces the amount of tissue is essential. In this study, we developed a procedure for the analysis of six THs; L-thyroxine (T4), 3,3',5-triiodo-l-thyronine (T3), 3,3',5'-triiodo-l-thyronine (rT3), 3,5-diiodo-l-thyronine (rT2), 3,3'-diiodo-l-thyronine (T2), 3-iodo-l-thyronine (T1) using isotope ((13)C6-T4, (13)C6-T3, (13)C6-rT3, (13)C6-T2) dilution liquid chromatography-mass spectrometry. The major difference with previously described methods lies in the utilization of a nano-UPLC (Ultra Performance Liquid Chromatography) system in micro configuration. This approach leads to a reduction compared to the published methods, of column internal diameter, flow rate, and injected volume. The result of all these improvements is a decrease in the amount of sample necessary for the analysis. The method was tested on six different mouse tissues: liver, heart, kidney, muscle, lung and brown adipose tissue (BAT). The nano-UPLC system was interfaced with a quadrupole time-of-flight mass spectrometer (Q-TOF2-MS) using the positive ion mode electrospray ionization. In our analytical method

  19. Quantitation of metabolites of the nerve agents sarin, soman, cyclohexylsarin, VX, and Russian VX in human urine using isotope-dilution gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Barr, John R; Driskell, W J; Aston, Linda S; Martinez, Rodolfo A

    2004-01-01

    Organophosphorus nerve agents are among the most toxic organic compounds known and continue to be a threat for both military and terrorist use. We have developed an isotope-dilution gas chromatography-tandem mass spectrometric (GC-MS-MS) method for quantitating the urinary metabolites of the organophosphorus nerve agents sarin (GB), soman (GD), VX, Russian VX (RVX), and cyclohexylsarin (GF). Urine samples were acidified, extracted into ether-acetonitrile, derivatized by methylation with diazomethane, and analyzed by GC-MS-MS. The limits of detection were less than 1 micro g/L for all analytes.

  20. Development of an Isotope-Dilution Liquid Chromatography/Mass Spectrometric Method for the Accurate Determination of Acetaminophen in Tablets

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hyun Ju; Kim, Byung Joo; Lee, Joon Hee; Hwang, Eui Jin [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2010-12-15

    Acetaminophen (N-acetyl-p-aminophenol) is one of the most popular analgesic and antipyretic drugs. An isotope dilution mass spectrometric method based on LC/MS was developed as a candidate reference method for the accurate determination of acetaminophen in pharmaceutical product. After spiking an isotope labeled acetaminophen (acetyl-{sup 13}C{sub 2}, {sup 15}Nacetaminophen) as an internal standard, tablet extracts were analyzed by LC/MS in a selected reaction monitoring (SRM) mode to detect ions at m/z 152→110 and m/z 155→111 for acetaminophen and acetyl-{sup 13}C{sub 2}, {sup 15}N-acetaminophen, respectively. The repeatability and reproducibility of the developed ID/LC-MS method were tested for the validation and assessment of metrological quality of the method.

  1. Determination of 4(5)-methylimidazole in carbonated beverages by isotope-dilution liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Ratnayake, Geemitha; Halldorson, Thor; Bestvater, Lianna; Tomy, Gregg T

    2015-01-01

    The purpose of this study was to develop a method to quantify 4(5)-methylimidazole (4-MEI), a suspected carcinogen, in carbonated beverages by simple sample dilution and isotope-dilution reverse-phase LC-MS/MS. Isotope dilution using hexa-deuterated methylimidazole (d6-4-MEI) was used to quantify native 4-MEI and to assess matrix effects quantitatively. The accuracy of the method was assessed by intentionally fortifying a negative control sample at three doses: low, medium and high (replicates of n = 5 each) with a known amount of 4-MEI. The respective absolute error in each case was 18.7 ± 0.7%, 14.6 ± 2.8% and 21.1 ± 9.7%. Within-day (intra-) and day-to-day (inter-) repeatability, determined as the relative standard deviation by fortifying a negative control sample (n = 5), were 9.5% and 15.4%, respectively. Average ion suppression of d6-4-MEI in beer was 63.9 ± 3.2%, while no suppression or enhancement was seen in non-alcoholic samples. The instrument and method limit of detection were calculated as 0.6 and 5.8 ng ml(-1), respectively. 4(5)-Methylimidazole was quantified in a variety of store-bought consumer beverages and it was found that in many of the samples tested consuming a single can of beer would result in intake levels of 4-MEI that exceed the no significant risk guideline of 29 µg day(-1). Conversely, 4-MEI in the samples was orders of magnitude smaller than the European Food Safety Authority acceptable daily intake threshold value of 100 mg kg(-1) bw day(-1).

  2. Determination of Glyphosate, its Degradation Product Aminomethylphosphonic Acid, and Glufosinate, in Water by Isotope Dilution and Online Solid-Phase Extraction and Liquid Chromatography/Tandem Mass Spectrometry

    Science.gov (United States)

    Meyer, Michael T.; Loftin, Keith A.; Lee, Edward A.; Hinshaw, Gary H.; Dietze, Julie E.; Scribner, Elisabeth A.

    2009-01-01

    The U.S. Geological Survey method (0-2141-09) presented is approved for the determination of glyphosate, its degradation product aminomethylphosphonic acid (AMPA), and glufosinate in water. It was was validated to demonstrate the method detection levels (MDL), compare isotope dilution to standard addition, and evaluate method and compound stability. The original method USGS analytical method 0-2136-01 was developed using liquid chromatography/mass spectrometry and quantitation by standard addition. Lower method detection levels and increased specificity were achieved in the modified method, 0-2141-09, by using liquid chromatography/tandem mass spectrometry (LC/MS/MS). The use of isotope dilution for glyphosate and AMPA and pseudo isotope dilution of glufosinate in place of standard addition was evaluated. Stable-isotope labeled AMPA and glyphosate were used as the isotope dilution standards. In addition, the stability of glyphosate and AMPA was studied in raw filtered and derivatized water samples. The stable-isotope labeled glyphosate and AMPA standards were added to each water sample and the samples then derivatized with 9-fluorenylmethylchloroformate. After derivatization, samples were concentrated using automated online solid-phase extraction (SPE) followed by elution in-line with the LC mobile phase; the compounds separated and then were analyzed by LC/MS/MS using electrospray ionization in negative-ion mode with multiple-reaction monitoring. The deprotonated derivatized parent molecule and two daughter-ion transition pairs were identified and optimized for glyphosate, AMPA, glufosinate, and the glyphosate and AMPA stable-isotope labeled internal standards. Quantitative comparison between standard addition and isotope dilution was conducted using 473 samples analyzed between April 2004 and June 2006. The mean percent difference and relative standard deviation between the two quantitation methods was 7.6 plus or minus 6.30 (n = 179), AMPA 9.6 plus or minus 8

  3. Determination of the alkylpyrazine composition of coffee using stable isotope dilution-gas chromatography-mass spectrometry (SIDA-GC-MS).

    Science.gov (United States)

    Pickard, Stephanie; Becker, Irina; Merz, Karl-Heinz; Richling, Elke

    2013-07-03

    A stable isotope dilution analysis based on gas chromatography-mass spectrometry analysis (SIDA-GC-MS) was developed for the quantitative analysis of 12 alkylpyrazines found in commercially available coffee samples. These compounds contribute to coffee flavor. The accuracy of this method was tested by analyzing model mixtures of alkylpyrazines. Comparisons of alkylpyrazine-concentrations suggested that water as extraction solvent was superior to dichloromethane. The distribution patterns of alkylpyrazines in different roasted coffees were quite similar. The most abundant alkylpyrazine in each coffee sample was 2-methylpyrazine, followed by 2,6-dimethylpyrazine, 2,5-dimethylpyrazine, 2-ethylpyrazine, 2-ethyl-6-methylpyrazine, 2-ethyl-5-methylpyrazine, and 2,3,5-trimethylpyrazine, respectively. Among the alkylpyrazines tested, 2,3-dimethylpyrazine, 2-ethyl-3-methylpyrazine, 2-ethyl-3,6-dimethylpyrazine, and 2-ethyl-3,5-dimethylpyrazine revealed the lowest concentrations in roasted coffee. By the use of isotope dilution analysis, the total concentrations of alkylpyrazines in commercially available ground coffee ranged between 82.1 and 211.6 mg/kg, respectively. Decaffeinated coffee samples were found to contain lower amounts of alkylpyrazines than regular coffee samples by a factor of 0.3-0.7, which might be a result of the decaffeination procedure.

  4. Accurate determination of selected pesticides in soya beans by liquid chromatography coupled to isotope dilution mass spectrometry.

    Science.gov (United States)

    Huertas Pérez, J F; Sejerøe-Olsen, B; Fernández Alba, A R; Schimmel, H; Dabrio, M

    2015-05-01

    A sensitive, accurate and simple liquid chromatography coupled with mass spectrometry method for the determination of 10 selected pesticides in soya beans has been developed and validated. The method is intended for use during the characterization of selected pesticides in a reference material. In this process, high accuracy and appropriate uncertainty levels associated to the analytical measurements are of utmost importance. The analytical procedure is based on sample extraction by the use of a modified QuEChERS (quick, easy, cheap, effective, rugged, safe) extraction and subsequent clean-up of the extract with C18, PSA and Florisil. Analytes were separated on a C18 column using gradient elution with water-methanol/2.5 mM ammonium acetate mobile phase, and finally identified and quantified by triple quadrupole mass spectrometry in the multiple reaction monitoring mode (MRM). Reliable and accurate quantification of the analytes was achieved by means of stable isotope-labelled analogues employed as internal standards (IS) and calibration with pure substance solutions containing both, the isotopically labelled and native compounds. Exceptions were made for thiodicarb and malaoxon where the isotopically labelled congeners were not commercially available at the time of analysis. For the quantification of those compounds methomyl-(13)C2(15)N and malathion-D10 were used respectively. The method was validated according to the general principles covered by DG SANCO guidelines. However, validation criteria were set more stringently. Mean recoveries were in the range of 86-103% with RSDs lower than 8.1%. Repeatability and intermediate precision were in the range of 3.9-7.6% and 1.9-8.7% respectively. LODs were theoretically estimated and experimentally confirmed to be in the range 0.001-0.005 mg kg(-1) in the matrix, while LOQs established as the lowest spiking mass fractionation level were in the range 0.01-0.05 mg kg(-1). The method reliably identifies and quantifies the

  5. Determination of mycotoxins in milk-based products and infant formula using stable isotope dilution assay and liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Kai; Wong, Jon W; Hayward, Douglas G; Vaclavikova, Marta; Liao, Chia-Ding; Trucksess, Mary W

    2013-07-03

    A stable isotope dilution assay and liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of 12 mycotoxins, aflatoxins B₁, B₂, G₁, G₂, and M₁, deoxynivalenol, fumonisins B₁, B₂, and B₃, ochratoxin A, T-2 toxin, and zearalenone, in milk-based infant formula and foods. Samples were fortified with 12 ¹³C uniformly labeled mycotoxins ([¹³C]-mycotoxins) that correspond to the 12 target mycotoxins and prepared by dilution and filtration, followed by LC-MS/MS analysis. Quantitation was achieved using the relative response factors of [¹³C]-mycotoxins and target mycotoxins. The average recoveries in fortified milk, milk-based infant formula, milk powder, and baby yogurt of aflatoxins B₁, B₂, G₁, and G₂ (2, 10, and 50 μg/kg), aflatoxin M₁ (0.5, 2.5, and 12.5 μg/kg), deoxynivalenol, fumonisins B₁, B₂, and B₃ (40, 200, and 1000 μg/kg), ochratoxin A, T-2 toxin, and zearalenone (20, 100, and 500 μg/kg), range from 89 to 126% with RSDs of mycotoxins, without using standard addition or matrix-matched calibration to compensate for matrix effects.

  6. Rapid and precise measurement of serum branched-chain and aromatic amino acids by isotope dilution liquid chromatography tandem mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Ruiyue Yang

    Full Text Available BACKGROUND: Serum branched-chain and aromatic amino acids (BCAAs and AAAs have emerged as predictors for the future development of diabetes and may aid in diabetes risk assessment. However, the current methods for the analysis of such amino acids in biological samples are time consuming. METHODS: An isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS method for serum BCAAs and AAAs was developed. The serum was mixed with isotope-labeled BCAA and AAA internal standards and the amino acids were extracted with acetonitrile, followed by analysis using LC/MS/MS. The LC separation was performed on a reversed-phase C18 column, and the MS/MS detection was performed via the positive electronic spray ionization in multiple reaction monitoring mode. RESULTS: Specific analysis of the amino acids was achieved within 2 min. Intra-run and total CVs for the amino acids were less than 2% and 4%, respectively, and the analytical recoveries ranged from 99.6 to 103.6%. CONCLUSION: A rapid and precise method for the measurement of serum BCAAs and AAAs was developed and may serve as a quick tool for screening serum BCAAs and AAAs in studies assessing diabetes risk.

  7. Ultra-trace level speciated isotope dilution measurement of Cr(VI) using ion chromatography tandem mass spectrometry in environmental waters.

    Science.gov (United States)

    Mädler, Stefanie; Todd, Aaron; Skip Kingston, H M; Pamuku, Matt; Sun, Fengrong; Tat, Cindy; Tooley, Robert J; Switzer, Teresa A; Furdui, Vasile I

    2016-08-15

    The reliable analysis of highly toxic hexavalent chromium, Cr(VI), at ultra-trace levels remains challenging, given its easy conversion to non-toxic trivalent chromium. This work demonstrates a novel analytical method to quantify Cr(VI) at low ngL(-1) concentration levels in environmental water samples by using speciated isotope dilution (SID) analysis and double-spiking with Cr(III) and Cr(VI) enriched for different isotopes. Ion chromatography tandem mass spectrometry (IC-MS/MS) was used for the analysis of Cr(VI) as HCrO4(-) → CrO3(-). Whereas the classical linear multipoint calibration (MPC) curve approach obtained a method detection limit (MDL) of 7ngL(-1) Cr(VI), the modified SID-MS method adapted from U. S. EPA 6800 allowed for the quantification of Cr(VI) with an MDL of 2ngL(-1) and provided results corrected for Cr(VI) loss occurred after sample collection. The adapted SID-MS approach proved to yield more accurate and precise results than the MPC method, allowed for compensation of Cr(VI) reduction during sample transportation and storage while eliminating the need for frequent external calibration. The developed method is a complementary tool to routinely used inductively-coupled plasma (ICP) MS and circumvents typically experienced interferences.

  8. Quantification of VX vapor in ambient air by liquid chromatography isotope dilution tandem mass spectrometric analysis of glass bead filled sampling tubes.

    Science.gov (United States)

    Evans, Ronald A; Smith, Wendy L; Nguyen, Nam-Phuong; Crouse, Kathy L; Crouse, Charles L; Norman, Steven D; Jakubowski, E Michael

    2011-02-15

    An analysis method has been developed for determining low parts-per-quadrillion by volume (ppqv) concentrations of nerve agent VX vapor actively sampled from ambient air. The method utilizes glass bead filled depot area air monitoring system (DAAMS) sampling tubes with isopropyl alcohol extraction and isotope dilution using liquid chromatography coupled with a triple-quadrupole mass spectrometer (LC/MS/MS) with positive ion electrospray ionization for quantitation. The dynamic range was from one-tenth of the worker population limit (WPL) to the short-term exposure limit (STEL) for a 24 L air sample taken over a 1 h period. The precision and accuracy of the method were evaluated using liquid-spiked tubes, and the collection characteristics of the DAAMS tubes were assessed by collecting trace level vapor generated in a 1000 L continuous flow chamber. The method described here has significant improvements over currently employed thermal desorption techniques that utilize a silver fluoride pad during sampling to convert VX to a higher volatility G-analogue for gas chromatographic analysis. The benefits of this method are the ability to directly analyze VX with improved selectivity and sensitivity, the injection of a fraction of the extract, quantitation using an isotopically labeled internal standard, and a short instrument cycle time.

  9. Simultaneous analysis of phthalates, adipate and polycyclic aromatic hydrocarbons in edible oils using isotope dilution-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Oh, Min-Seok; Lee, Seon-Hwa; Moon, Myeong Hee; Lee, Dong Soo; Park, Hyun-Mee

    2014-01-01

    A method for simultaneous determination of 12 priority phthalates, adipate and polycyclic aromatic hydrocarbons (PAHs) in edible oils by isotope dilution-gas chromatography-mass spectrometry (ID-GC-MS) was developed for fast, accurate and trace analysis. The extraction and clean-up procedures were optimised, and using stable isotope-labelled internal standards for each analyte, relative standard deviations (RSDs) of 0.92-10.6% and spiked sample recoveries of 80.6-97.8% were obtained. Limits of detection for PAHs were in the range of 0.15-0.77 µg/kg and those for phthalates were in the range of 4.6-10.0 µg/kg. The calibration curves exhibited good linearities with regression coefficients of R(2) ≥ 0.99. Twelve edible oils were examined to evaluate the efficiency of this method. Among the 12 analytes, dibutyl phthalates (DBP), diethylhexyl phthalates (DEHP), diethylhexyl adipate (DEHA), benzo[a]anthracene (B[a]A), chrysene (Chry) and benzo[b]fluoranthene (B[b]F) were detected in the range of 1.17-806 µg/kg.

  10. An improved reference measurement procedure for triglycerides and total glycerides in human serum by isotope dilution gas chromatography-mass spectrometry.

    Science.gov (United States)

    Chen, Yizhao; Liu, Qinde; Yong, Sharon; Teo, Hui Ling; Lee, Tong Kooi

    2014-01-20

    Triglycerides are widely tested in clinical laboratories using enzymatic methods for lipid profiling. As enzymatic methods can be affected by interferences from biological samples, this together with the non-specific nature of triglycerides measurement makes it necessary to verify the accuracy of the test results with a reference measurement procedure. Several such measurement procedures had been published. These procedures generally involved lengthy and laborious sample preparation steps. In this paper, an improved reference measurement procedure for triglycerides and total glycerides was reported which simplifies the sample preparation steps and greatly shortens the time taken. The procedure was based on isotope dilution gas chromatography-mass spectrometry (IDGC-MS)with tripalmitin as the calibration standard. Serum samples were first spiked with isotope-labeled tripalmitin. For the measurement of triglycerides, the serum samples were subjected to lipid extraction followed by separation of triglycerides from diglycerides and monoglycerides. Triglycerides were then hydrolyzed to glycerol, derivatized and injected into the GC–MS for quantification. For the measurement of total glycerides, the serum samples were hydrolyzed directly and derivatized before injection into the GC-MS for quantification. All measurement results showed good precision with CV triglycerides and total glycerides were well within the certified ranges of the CRM, with deviation triglycerides and total glycerides.

  11. Direct determination of fatty acid esters of 3-chloro-1, 2-propanediol in edible vegetable oils by isotope dilution - ultra high performance liquid chromatography - triple quadrupole mass spectrometry.

    Science.gov (United States)

    Li, Heli; Chen, Dawei; Miao, Hong; Zhao, Yunfeng; Shen, Jianzhong; Wu, Yongning

    2015-09-04

    A selective and sensitive ultra-high performance liquid chromatography - triple quadrupole mass spectrometry (UHPLC-MS/MS) method coupled with matrix solid phase dispersion (MSPD) extraction was developed for the direct determination of fatty acid esters of 3-chloro-1,2-propanediol (3-MCPD esters) in edible vegetable oils. The method integrated the isotope dilution technique, MSPD extraction and UHPLC - MS/MS analysis with multi-reaction monitoring mode (MRM). Matrix-matched calibration curves showed good linearity within the range of 0.01-10mgL(-1) with the correlation coefficient not less than 0.999. Limits of detection (LODs) and limit of quantification (LOQs) of the 3-MCPD esters fell into the range of 0.0001-0.02mgkg(-1) and 0.0004-0.05mgkg(-1), respectively. The recoveries for the spiked extra virgin olive oils ranged from 94.4% to 108.3%, with the relative standard deviations (RSD) ranging from 0.6% to 10.5%. The method was applied for the oil sample (T2642) of the official Food Analysis Performance Assessment Scheme (FAPAS) in 2014 and other real samples from supermarket, and the results showed that the present method was comparative to the gas chromatography-mass spectrometry (GC-MS) method based on the improved German Society for Fat Science (DGF) standard method C-III 18 (09) except for palm oil.

  12. Quantification of 16 polycyclic aromatic hydrocarbons in cigarette smoke condensate using stable isotope dilution liquid chromatography with atmospheric-pressure photoionization tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Xiaotao; Hou, Hongwei; Chen, Huan; Liu, Yong; Wang, An; Hu, Qingyuan

    2015-09-17

    A stable isotope dilution liquid chromatography with tandem mass spectrometry method for the analysis of 16 polycyclic aromatic hydrocarbons in cigarette smoke condensate was developed and validated. Compared with previously reported methods, this method has lower limits of detection (0.04-1.35 ng/cig). Additionally, the proposed method saves time, reduces the number of separation steps, and reduces the quantity of solvent needed. The new method was applied to evaluate polycyclic aromatic hydrocarbon content in 213 commercially available cigarettes in China, under the International Standardization Organization smoking regime and the Health Canadian intense smoking regime. The results showed that the total polycyclic aromatic hydrocarbon content was more than two times higher in samples from the Health Canadian intense smoking regime than in samples from the International Standardization Organization smoking regime (1189.23 vs. 2859.50 ng/cig, ppolycyclic aromatic hydrocarbons (and total polycyclic aromatic hydrocarbons) increased with labeled tar content in both of the tested smoking regimes. There was a positive correlation between total polycyclic aromatic hydrocarbons under the International Standardization Organization smoking regime with that under the Health Canadian intense smoking regime. The proposed liquid chromatography with tandem mass spectrometry method is satisfactory for the rapid, sensitive, and accurately quantitative evaluation of polycyclic aromatic hydrocarbon content in cigarette smoke condensate, and it can be applied to assess potential health risks from smoking. This article is protected by copyright. All rights reserved.

  13. Quantification of carcinogenic 4- to 6-ring polycyclic aromatic hydrocarbons in human urine by solid-phase microextraction gas chromatography-isotope dilution mass spectrometry.

    Science.gov (United States)

    Campo, Laura; Fustinoni, Silvia; Bertazzi, Pieralberto

    2011-08-01

    Polycyclic aromatic hydrocarbons (PAHs) are pollutants found in living and working environments. The aim of this study was to develop a solid-phase microextraction (SPME) gas chromatography (GC)-isotope dilution mass spectrometry method for the quantification of 10 four- to six-ring PAHs in urine samples. Seven of the selected PAHs have been classified as carcinogenic. Under the final conditions, analytes were sampled with a 100-μm polydimethylsiloxane SPME fibre for 60 min at 80 °C and desorbed in the injection port of the GC at 270 °C. Fluoranthene, pyrene, benz[a]anthracene, chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenzo[a,h]anthracene, indeno[1,2,3-cd]pyrene and benzo[ghi]perylene were separated using a highly arylene-modified phase capillary column and quantified by MS using eight deuterated PAHs as surrogate internal standards. Limits of quantification (LOQ) were in the 0.5- to 2.2-ng/L range. Validation showed linear dynamic ranges up to 340 ng/L, inter- and intra-run precisions <20%, and accuracies within 20% of spiked concentrations. Matrix effect evaluation and the use of control charts to monitor process performances showed that the isotope dilution approach allowed for the control of bias sources. Urinary PAHs were above or equal to LOQ, depending on different compounds, in 58-100% (min-max), 40-100% and 5-39% of samples from coke oven workers (n = 12), asphalt workers (n = 10) and individuals not occupationally exposed to PAHs (n = 18), respectively. Chrysene was the most abundant PAH determined with median levels of 62.6, 6.9 and <0.6 ng/L, respectively. These results show that the method is suitable for quantifying carcinogenic PAHs in specimens from individuals with different levels of PAH exposure.

  14. Quantification of 2-acetyl-1-pyrroline in rice by stable isotope dilution assay through headspace solid-phase microextraction coupled to gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Maraval, Isabelle; Sen, Kemal; Agrebi, Abdelhamid; Menut, Chantal; Morere, Alain; Boulanger, Renaud; Gay, Frédéric; Mestres, Christian; Gunata, Ziya

    2010-08-24

    A new and convenient synthesis of 2-acetyl-1-pyrroline (2AP), a potent flavor compound in rice, and its ring-deuterated analog, 2-acetyl-1-d(2)-pyrroline (2AP-d(2)), was reported. A stable isotope dilution assay (SIDA), involving headspace solid-phase microextraction (HS-SPME) combined with gas chromatography-positive chemical ionization-ion trap-tandem mass spectrometry (GC-PCI-IT-MS-MS), was developed for 2AP quantification. A divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) fiber was used for HS-SPME procedure and parameters affecting analytes recovery, such as extraction time and temperature, pH and salt, were studied. The repeatability of the method (n=10) expressed as relative standard deviation (RSD) was 11.6%. A good linearity was observed from 5.9 to 779 ng of 2AP (r(2)=0.9989). Limits of detection (LOD) and quantification (LOQ) for 2AP were 0.1 and 0.4 ng g(-1) of rice, respectively. The recovery of spiked 2AP from rice matrix was almost complete. The developed method was applied to the quantification of 2AP in aerial parts and grains of scented and non-scented rice cultivars.

  15. Quantification of 2-acetyl-1-pyrroline in rice by stable isotope dilution assay through headspace solid-phase microextraction coupled to gas chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Maraval, Isabelle [UMR Qualisud, CIRAD, 73 Rue J. F. Breton, 34398 Montpellier Cedex 5 (France); UMR Qualisud, Universite Montpellier 2, place E. Bataillon, 34095 Montpellier Cedex 5 (France); Sen, Kemal [Department of Food Engineering, Faculty of Agriculture, University of Cukurova, 01330 Adana (Turkey); Agrebi, Abdelhamid; Menut, Chantal; Morere, Alain [UMR 5247, Institut des Biomolecules Max Mousseron (IBMM), CNRS, Universites Montpellier 2 et 1, Ecole Nationale Superieure de Chimie de Montpellier, 8 Rue de l' Ecole Normale, 34296 Montpellier Cedex 5 (France); Boulanger, Renaud [UMR Qualisud, CIRAD, 73 Rue J. F. Breton, 34398 Montpellier Cedex 5 (France); Gay, Frederic [CIRAD, DORAS Centre, Research and Development Building, Kasetsart University, Bangkok 10900 (Thailand); Mestres, Christian [UMR Qualisud, CIRAD, 73 Rue J. F. Breton, 34398 Montpellier Cedex 5 (France); Gunata, Ziya, E-mail: zgunata@univ-montp2.fr [UMR Qualisud, Universite Montpellier 2, place E. Bataillon, 34095 Montpellier Cedex 5 (France)

    2010-08-24

    A new and convenient synthesis of 2-acetyl-1-pyrroline (2AP), a potent flavor compound in rice, and its ring-deuterated analog, 2-acetyl-1-d{sub 2}-pyrroline (2AP-d{sub 2}), was reported. A stable isotope dilution assay (SIDA), involving headspace solid-phase microextraction (HS-SPME) combined with gas chromatography-positive chemical ionization-ion trap-tandem mass spectrometry (GC-PCI-IT-MS-MS), was developed for 2AP quantification. A divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) fiber was used for HS-SPME procedure and parameters affecting analytes recovery, such as extraction time and temperature, pH and salt, were studied. The repeatability of the method (n = 10) expressed as relative standard deviation (RSD) was 11.6%. A good linearity was observed from 5.9 to 779 ng of 2AP (r{sup 2} = 0.9989). Limits of detection (LOD) and quantification (LOQ) for 2AP were 0.1 and 0.4 ng g{sup -1} of rice, respectively. The recovery of spiked 2AP from rice matrix was almost complete. The developed method was applied to the quantification of 2AP in aerial parts and grains of scented and non-scented rice cultivars.

  16. Regional water-quality analysis of 2,4-D and dicamba in river water using gas chromatography-isotope dilution mass spectrometry

    Science.gov (United States)

    Thurman, E.M.; Zimmerman, L.R.; Aga, D.S.; Gilliom, R.J.

    2001-01-01

    Gas chromatography with isotope dilution mass spectrometry (GC-MS) and enzyme-linked immunosorbent assay (ELISA) were used in regional National Water Quality Assessment studies of the herbicides, 2,4-D and dicamba, in river water across the United States. The GC-MS method involved solid-phase extraction, derivatized with deutemted 2,4-D, and analysis by selected ion monitoring. The ELISA method was applied after preconcentration with solid-phase extraction. The ELISA method was unreliable because of interference from humic substances that were also isolated by solid-phase extraction. Therefore, GC-MS was used to analyzed 80 samples from river water from 14 basins. The frequency of detection of dicamba (28%) was higher than that for 2,4-D (16%). Concentrations were higher for dicamba than for 2,4-D, ranging from less than the detection limit (<0.05 ??g/L) to 3.77 ??g/L, in spite of 5 times more annual use of 2,4-D as compared to dicamba. These results suggest that 2,4-D degrades more rapidly in the environment than dicamba.

  17. Determination of nerve agent metabolites in human urine by isotope-dilution gas chromatography-tandem mass spectrometry after solid phase supported derivatization.

    Science.gov (United States)

    Lin, Ying; Chen, Jia; Yan, Long; Guo, Lei; Wu, Bidong; Li, Chunzheng; Feng, Jianlin; Liu, Qin; Xie, Jianwei

    2014-08-01

    A simple and sensitive method has been developed and validated for determining ethyl methylphosphonic acid (EMPA), isopropyl methylphosphonic acid (IMPA), isobutyl methylphosphonic acid (iBuMPA), and pinacolyl methylphosphonic acid (PMPA) in human urine using gas chromatography-tandem mass spectrometry (GC-MS/MS) coupled with solid phase derivatization (SPD). These four alkyl methylphosphonic acids (AMPAs) are specific hydrolysis products and biomarkers of exposure to classic organophosphorus (OP) nerve agents VX, sarin, RVX, and soman. The AMPAs in urine samples were directly derivatized with pentafluorobenzyl bromide on a solid support and then extracted by liquid-liquid extraction. The analytes were quantified with isotope-dilution by negative chemical ionization (NCI) GC-MS/MS in a selected reaction monitoring (SRM) mode. This method is highly sensitive, with the limits of detection of 0.02 ng/mL for each compound in a 0.2 mL sample of human urine, and an excellent linearity from 0.1 to 50 ng/mL. It is proven to be very suitable for the qualitative and quantitative analyses of degradation markers of OP nerve agents in biomedical samples.

  18. Quantitative analysis of metabolites in complex biological samples using ion-pair reversed-phase liquid chromatography-isotope dilution tandem mass spectrometry.

    Science.gov (United States)

    Seifar, Reza M; Zhao, Zheng; van Dam, Jan; van Winden, Wouter; van Gulik, Walter; Heijnen, Joseph J

    2008-04-11

    A rapid, sensitive and selective ion-pair reversed-phase liquid chromatography-electrospray ionization isotope dilution tandem mass spectrometry (IP-LC-ESI-ID-MS/MS) was developed for quantitative analysis of free intracellular metabolites in cell cultures. As an application a group of compounds involved in penicillin biosynthesis pathway of Penicillium chrysogenum cells, such as penicillin G (PenG), 6-aminopenicillanic acid (6-APA), benzylpenicilloic acid (PIO), ortho-hydroxyphenyl acetic acid (o-OH-PAA), phenylacetic acid (PAA), 6-oxopipeidine-2-carboxylic acid (OPC), 8-hydroxypenicillic acid (8-HPA), L-alpha-(delta-aminoadipyl)-L-alpha-cystenyl-D-alpha-valine (ACV) and isopenicillin N (IPN) were chosen. (13)C-labeled analogs of the metabolites were added to the sample solutions as internal standards (I.S.). Sample mixtures were analyzed without any sample pretreatment. No extraction recovery check was needed because I.S. was added to the cell samples before extraction process. The method showed excellent precision (relative standard deviation (RSD)

  19. Quantification of 13 priority polycyclic aromatic hydrocarbons in human urine by headspace solid-phase microextraction gas chromatography-isotope dilution mass spectrometry.

    Science.gov (United States)

    Campo, Laura; Mercadante, Rosa; Rossella, Federica; Fustinoni, Silvia

    2009-01-12

    Polycyclic aromatic hydrocarbons (PAHs) are common environmental pollutants in both living and working environments. The aim of this study was the development of a headspace solid-phase microextraction gas chromatography-isotope dilution mass spectrometry (HS-SPME/GC-IDMS) method for the simultaneous quantification of 13 PAHs in urine samples. Different parameters affecting PAHs extraction by HS-SPME were considered and optimized: type/thickness of fiber coatings, extraction temperature/time, desorption temperature/time, ionic strength and sample agitation. The stability of spiked PAHs solutions and of real urine samples stored up to 90 days in containers of different materials was evaluated. In the optimized method, analytes were absorbed for 60min at 80 degrees C in the sample headspace with a 100mum polydimethylsiloxane fiber. The method is very specific, with linear range from the limit of quantification to 8.67 x 10(3)ngL(-1), a within-run precision of <20% and a between-run precision of <20% for 2-, 3- and 4-ring compounds and of <30% for 5-ring compounds, trueness within 20% of the spiked concentration, and limit of quantification in the 2.28-2.28 x 10(1)ngL(-1) range. An application of the proposed method using 15 urine samples from subjects exposed to PAHs at different environmental levels is shown.

  20. Quantification of 13 priority polycyclic aromatic hydrocarbons in human urine by headspace solid-phase microextraction gas chromatography-isotope dilution mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Campo, Laura [Department of Occupational and Environmental Health, University of Milan and Fondazione IRCCS Ospedale Maggiore Policlinico, Mangiagalli e Regina Elena, Milan (Italy)], E-mail: laura.campo@unimi.it; Mercadante, Rosa; Rossella, Federica; Fustinoni, Silvia [Department of Occupational and Environmental Health, University of Milan and Fondazione IRCCS Ospedale Maggiore Policlinico, Mangiagalli e Regina Elena, Milan (Italy)

    2009-01-12

    Polycyclic aromatic hydrocarbons (PAHs) are common environmental pollutants in both living and working environments. The aim of this study was the development of a headspace solid-phase microextraction gas chromatography-isotope dilution mass spectrometry (HS-SPME/GC-IDMS) method for the simultaneous quantification of 13 PAHs in urine samples. Different parameters affecting PAHs extraction by HS-SPME were considered and optimized: type/thickness of fiber coatings, extraction temperature/time, desorption temperature/time, ionic strength and sample agitation. The stability of spiked PAHs solutions and of real urine samples stored up to 90 days in containers of different materials was evaluated. In the optimized method, analytes were absorbed for 60 min at 80 deg. C in the sample headspace with a 100 {mu}m polydimethylsiloxane fiber. The method is very specific, with linear range from the limit of quantification to 8.67 x 10{sup 3} ng L{sup -1}, a within-run precision of <20% and a between-run precision of <20% for 2-, 3- and 4-ring compounds and of <30% for 5-ring compounds, trueness within 20% of the spiked concentration, and limit of quantification in the 2.28-2.28 x 10{sup 1} ng L{sup -1} range. An application of the proposed method using 15 urine samples from subjects exposed to PAHs at different environmental levels is shown.

  1. Isotope dilution gas chromatography with mass spectrometry for the analysis of 4-octyl phenol, 4-nonylphenol, and bisphenol A in vegetable oils.

    Science.gov (United States)

    Wu, Pinggu; Zhang, Liqun; Yang, Dajin; Zhang, Jing; Hu, Zhengyan; Wang, Liyuan; Ma, Bingjie

    2016-03-01

    By the combination of solid-phase extraction as well as isotope dilution gas chromatography with mass spectrometry, a sensitive and reliable method for the determination of endocrine-disrupting chemicals including bisphenol A, 4-octylphenol, and 4-nonylphenol in vegetable oils was established. The application of a silica/N-(n-propyl)ethylenediamine mixed solid-phase extraction cartridge achieved relatively low matrix effects for bisphenol A, 4-octylphenol, and 4-nonylphenol in vegetable oils. Experiments were designed to evaluate the effects of derivatization, and the extraction parameters were optimized. The estimated limits of detection and quantification for bisphenol A, 4-octylphenol, and 4-nonylphenol were 0.83 and 2.5 μg/kg, respectively. In a spiked experiment in vegetable oils, the recovery of the added bisphenol A was 97.5-110.3%, recovery of the added 4-octylphenol was 64.4-87.4%, and that of 4-nonylphenol was 68.2-89.3%. This sensitive method was then applied to real vegetable oil samples from Zhejiang Province of China, and none of the target compounds were detected.

  2. Thin-layer chromatography/direct analysis in real time time-of-flight mass spectrometry and isotope dilution to analyze organophosphorus insecticides in fatty foods.

    Science.gov (United States)

    Kiguchi, Osamu; Oka, Kazuko; Tamada, Masafumi; Kobayashi, Takashi; Onodera, Jun

    2014-11-28

    To assess food safety emergencies caused by highly hazardous chemical-tainted foods, simultaneous analysis of organophosphorus insecticides in fatty foods such as precooked foods was conducted using thin-layer chromatography/direct analysis in real time time-of-flight mass spectrometry (TLC/DART-TOFMS) and isotope dilution technique. Polar (methamidophos and acephate) and nonpolar organophosphorus insecticides (fenitrothion, diazinon, and EPN) were studied. Experiments to ascertain chromatographic patterns using TLC/DART-TOFMS reveal that it was more useful than GC/MS or GC/MS/MS for the simultaneous analyses of polar and nonpolar pesticides, while obviating the addition of a protective agent for tailing effects of polar pesticides. Lower helium gas temperature (260°C) for DART-TOFMS was suitable for the simultaneous analysis of target pesticides. Linearities were achieved respectively at a lower standard concentration range (0.05-5 μg) for diazinon and EPN and at a higher standard concentration range (2.5-25 μg) for methamidophos, acephate, and fenitrothion. Their respective coefficients of determination were ≥ 0.9989 and ≥ 0.9959. A few higher repeatabilities (RSDs) for diazinon and EPN were found (>20%), although isotope dilution technique was used. Application to the HPTLC plate without an automatic TLC sampler might be inferred as a cause of their higher RSDs. Detection limits were estimated in the higher picogram range for diazinon and EPN, and in the lower nanogram range for methamidophos, acephate, and fenitrothion. Aside from methamidophos, recovery results (n=3) obtained using a highly insecticide-tainted fatty food (dumpling) and raw food (grapefruit) samples (10mg/kg) using TLC/DART-TOFMS with both complex and simpler cleanups were not as susceptible to matrix effects (95-121%; RSD, 1.3-14%) as those using GC/MS/MS (102-117%; RSD, 0.4-8.5%), although dumpling samples using GC/MS were remarkably susceptible to matrix effects. The coupled method of

  3. Quantitative analysis of paraquat in vegetation by stable isotope dilution and liquid chromatography/electrospray ionization-mass spectrometry.

    Science.gov (United States)

    Schaner, Angela; Hickes, Heidi

    2015-01-01

    The method presented is a suitable approach for routine testing of paraquat in difficult sample types, such as winter wheat and alfalfa plant tissue, typically found with accidental spray drift. Hydrophilic interaction chromatography and ultra-performance LC is utilized with tandem quadrupole MS in the positive electrospray ionization mode. Three precursor-product ion transitions are measured in the multiple reaction monitoring mode, and paraquat d8 is added as an internal standard at the beginning of the extraction procedure to correct for losses in recovery and/or matrix effects in instrument response. A 5 g portion is digested with 6 M HCl in a 100°C water bath for 1 h. An aliquot is removed and adjusted to pH 7-8 prior to loading on a mixed mode weak cation-exchange SPE cartridge, and paraquat is eluted with formic acid-acetonitrile (10 + 90, v/v). Average recoveries of paraquat fortified at 0.020-0.080 ppm in winter wheat and alfalfa ranged from 80 to 114% (RSD 12-30%). Result data from naturally incurred paraquat (0.027-0.51 ppm) in composite garden plants, potato leaves, tree leaves, and alfalfa are presented. The LOQ is 0.020 ppm.

  4. Determination of eugenol in fish and shrimp muscle tissue by stable isotope dilution assay and solid-phase extraction coupled gas chromatography-triple quadrupole mass spectrometry.

    Science.gov (United States)

    Li, Jincheng; Liu, Huan; Wang, Chaoying; Wu, Lidong; Liu, Dan

    2016-09-01

    In this study, we developed a new method for the accurate quantification of eugenol in fish samples based on stable isotope dilution assay (SIDA) and solid-phase extraction (SPE) coupled gas chromatography-triple quadrupole mass spectrometry (SIDA-SPE-GC-MS/MS). Due to the difference of matrix effect (ME), it was difficult to determine accurately the level of eugenol residue in different fish and shrimp samples based on external standard calibration method. SIDA was applied to compensate matrix effect (ME) that eugenol-d3 was used as internal standard (IS). Freshwater fish (carp, channel catfish), marine fish (turbot), and shrimp (Penaeus vannawei) were used for the method validation. The average recoveries of eugenol were in the range of 94.7 to 109.78 % when the spiking levels were 10, 50, and 200 μg kg(-1). The inter-day and intra-day precisions were in the range of 1.15-8.19 and 0.71-8.45 %. The limit of detection (LOD) and the limit of quantification (LOQ) were approximately 2.5 and 5.0 μg kg(-1). This method was applied to the real fish samples assay obtained from aquaculture markets in Beijing, China. Eugenol residue was found in two fish samples with the levels at 6.2 and 7.7 μg kg(-1), respectively. Graphical abstract Determination of eugenol in fish and shrimp muscle tissue.

  5. Analysis of advanced glycation endproducts in dairy products by isotope dilution liquid chromatography-electrospray tandem mass spectrometry. The particular case of carboxymethyllysine.

    Science.gov (United States)

    Delatour, Thierry; Hegele, Jörg; Parisod, Véronique; Richoz, Janique; Maurer, Sarah; Steven, Matthew; Buetler, Timo

    2009-03-20

    A fully validated multiple-transition recording isotope dilution liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantitative determination of N(epsilon)-carboxymethyllysine (CML) and lysine in dairy products is described. Internal standards were [N-1',2'-(13)C(2)]CML and [1,2,3,4,5,6-(13)C(6)-2,6-(15)N(2)]lysine, and the method was validated by evaluating the selectivity, linearity, precision (repeatability and reproducibility) and trueness, using both powder and liquid products. For liquid dairy products, the repeatability and reproducibility was 2.79% and 11.0%, while 4.85% and 4.92% were determined for powder dairy products, respectively. The trueness of the method ranged from -9.6% to -3.6% for powder and from -0.99% to 6.8% for liquid dairy products. The limit of detection for CML was estimated to be 8 ng CML per mg protein while the limit of quantification was 27 ng CML per mg protein. The method encompasses a proteolytic cleavage mediated by enzymatic digestion to reach a complete release of the amino acids prior to a sample cleanup based on solid phase extraction, and followed by LC-MS/MS analysis of CML and lysine residues. To ensure a suitable performance of the enzymatic digestion, CML measurements were compared to values obtained with an acid hydrolysis-mediated proteolysis. Finally, the method was employed for the analysis of CML in various dairy products. The values compare well to the data available in the literature when similar methods were used, even if some discrepancies were observed upon comparison with the results obtained by other techniques such as enzyme-linked immunosorbent assay and GC-MS.

  6. Development and validation of a stable-isotope dilution liquid chromatography-tandem mass spectrometry method for the determination of bisphenols in ready-made meals.

    Science.gov (United States)

    Regueiro, Jorge; Wenzl, Thomas

    2015-10-01

    Due to their growing consumption, ready-made meals are a major dietary component for many people in today's society, representing an important potential route of human exposure to several food contaminants. The recent restrictions in the use of bisphenol A have led the plastic industry to look for alternative chemicals, most of them belonging to the same family of p,p'-bisphenols. The aim of the current work was to develop and validate a method based on stable-isotope dilution liquid chromatography-tandem mass spectrometry for the analysis of bisphenol A and its main analogs - bisphenol S, 4,4'-sulfonylbis(2-methylphenol), bisphenol F, bisphenol E, bisphenol B, bisphenol Z, bisphenol AF, bisphenol AP, tetrabromobisphenol A and bisphenol P - in solid foodstuffs, and particularly in ready-made meals. Extraction was carried out by ultrasound-assisted extraction after sample disruption with sand. A selective solid-phase extraction procedure was then applied to reduce potential matrix interferences. Derivatization of bisphenols with pyridine-3-sulfonyl chloride increased their ionization efficiency by electrospray ionization. Validation of the proposed method was performed in terms of selectivity, matrix effects, linearity, precision, measurement uncertainty, trueness and limits of detection. Satisfactory repeatability and intermediate precision were obtained; the related relative standard deviations were ≤7.8% and ≤10%, respectively. The relative expanded uncertainty (k=2) was below 17% for all bisphenol analogs and the trueness of the method was demonstrated by spike recovery experiments. Low limits of detection, in the range from 0.025μgkg(-1) to 0.140μgkg(-1), were obtained for all compounds. To demonstrate the applicability of the proposed method, it was eventually applied to several ready-made meals purchased from different supermarkets in Belgium.

  7. [Determination of mono- to tri-chlorinated dibenzo-p-dioxins and dibenzofurans in stack gas using isotope dilution high resolution gas chromatography-high resolution mass spectrometry].

    Science.gov (United States)

    Tang, Chen; Liu, Qipeng; Tian, Zhenyu; Xie, Huiting; Wang, Mengjing; Liu, Wenbin

    2014-09-01

    A method for the determination of mono- to tri-chlorinated dibenzo-p-dioxins and dibenzofurans (mono- to tri-CDD/Fs) in stack gas using isotope dilution high resolution gas chromatography-high resolution mass spectrometry (HRGC-HRMS) was developed. The sam- ples were extracted by Soxhlet extraction, and then the extracts were concentrated and purified using a multilayer silica gel column and a basic alumina column. The analytes were separated by HRGC on a DB-5MS column (30 m x 0.25 mm x 0.25 μm) and determined by HRMS. The identi- fication of mono- to tri-CDD/Fs was based on the retention times of 13C-labelled standard and the abundance ratios of the two exacted mass-to-charge ratios. The quantitative analysis was performed using the ratios of the integrated areas of the 13C-labelled standards. This method had the recoveries ranging from 66.6% to 112.5% and the relative standard deviations (RSD) ranging from 19.9% to 40.5% (n = 5). The limits of detection (LODs) of this method for the mono- to tri-CDD/Fs were ranging from 0.027 to 0.485 μg/L. Three stack gas samples from waste incinerators were measured using this method, with the recoveries ranging from 85.7% to 137.0% and the concentrations ranging from 11.4 to 9,183 pg/Nm3. The results indicated that the method can be applied to the precise determination of mono- to tri-CDD/Fs at trace level in stack gas.

  8. [Determination of 18 pesticide residues in red wine by ultra high performance liquid chromatography-high resolution mass spectrometry with isotope dilution technique].

    Science.gov (United States)

    Chen, Dawei; Lü, Bing; Ding, Hao; Zou, Jianhong; Yang, Xin; Zhao, Yunfeng; Miao, Hong

    2014-05-01

    A method for the simultaneous determination of 18 pesticide residues in red wine was developed using ultra high performance liquid chromatography-high resolution mass spectrometry (UPLC-HRMS) with isotope dilution technique. The red wine samples were extracted with acetonitrile, and the extracts were cleaned up with dispersive solid phase extraction (dSPE) using the mixture of N-propyl ethylene diamine (PSA) and C18 powder as sorbent. The extracted components were separated on a BEH C18 column by gradient elution. The qualitative and quantitative analyses were operated under full scan/data dependent MS/MS (ddms2) and targeted selective ion monitoring (tSIM) by high resolution mass spectrometry, respectively. Carbendazim-D4, chlorpyrifos-D10, imidacloprid-D4, methoxyfenozide-D9, pyrimethanil-D5 and tebuconazole-D6 were used as the internal standards to reduce the matrix effects. The response of each pesticide showed a good linearity in the range of 0.5-50 microg/kg with the correlation coefficient more than 0.999. The limits of detection and quantification for the 18 pesticides in the spiked blank red wine were 0.5 microg/kg and 1.0 microg/kg, respectively. The recovery results with spiked blank red wine samples at the levels of 1 to 40 microg/kg were satisfactory with average recoveries of 85.4% - 117.9% and the RSDs of 0.5%-6.1%. The method was applied for the determination of the red wine real samples from the market. Carbendazim, imidacloprid, pyrimethanil, tebuconazole and triadimenol were detected in the samples. The results show that the method is suitable for the rapid screening and quantitative analysis of pesticide residues in red wine.

  9. Isotope dilution liquid chromatography-tandem mass spectrometry for simultaneous identification and quantification of beta-casomorphin 5 and beta-casomorphin 7 in yoghurt.

    Science.gov (United States)

    Nguyen, D D; Solah, V A; Johnson, S K; Charrois, J W A; Busetti, F

    2014-03-01

    A highly selective and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous identification and quantification of beta-casomorphin 5 (BCM5) and beta-casomorphin 7 (BCM7) in yoghurt. The method used deuterium labelled BCM5-d10 and BCM7-d10 as surrogate standards for confident identification and accurate and quantification of these analytes in yoghurt. Linear responses for BCM5 and BCM7 (R(2)=0.9985 and 0.9986, respectively) was observed in the range 0.01-10ng/μL. The method limits of detection (MLDs) in yoghurt extracts were found to be 0.5 and 0.25ng/g for BCM5 and BCM7, respectively. Analyses of spiked samples were used to provide confirmation of accuracy and precision of the analytical method. Recoveries relative to the surrogate standards of these spikes were in the range of 95-106% for BCM5 and 103-109% for BCM7. Precision from analysis of spiked samples was expressed as relative standard deviation (%RSD) and values were in the range 1-16% for BCM5 and 1-6% for BCM7. Inter-day reproducibility was between 2.0-6.4% for BCM5 and between 3.2-6.1% for BCM7. The validated isotope dilution LC-MS/MS method was used to measure BCM5 and BCM7 in ten commercial and laboratory prepared samples of yoghurt and milk. Neither BCM5 nor BCM7 was detected in commercial yoghurts. However, they were observed in milk and laboratory prepared yoghurts and interestingly their levels decreased during processing. BCM5 decreased from 1.3ng/g in milk to 1.1ng/g in yoghurt made from that milk at 0day storage and yoghurts immediately after processing. These preliminary results indicate that fermentation and storage reduced BCM5 and BCM7 concentration in yoghurt. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Quantitative Analysis by Isotopic Dilution Using Mass Spectroscopy: The Determination of Caffeine by GC-MS.

    Science.gov (United States)

    Hill, Devon W.; And Others

    1988-01-01

    Describes a laboratory technique for quantitative analysis of caffeine by an isotopic dilution method for coupled gas chromatography-mass spectroscopy. Discusses caffeine analysis and experimental methodology. Lists sample caffeine concentrations found in common products. (MVL)

  11. Water Metabolism of Walruses by Isotope Dilution

    DEFF Research Database (Denmark)

    Acquarone, M.; Born, E. W.; Chwalibog, A.

    In August 2000, the hydrogen isotope dilution method was used on 7 adult male Atlantic walruses (Odobenus rosmarus rosmarus) (weight: 1197±148 kg, mean±SD, range 1013-1508 kg) at a terrestrial haul-out in Northeastern Greenland to determine their body water pool sizes and body water turnover rates...... was sampled via an epidural catheter, at regular intervals, for up to seven hours after the initial enrichment to assess isotope equilibration in the body water pools. Five individuals returned to the haul-out after feeding trips of varying duration (158±86 hr, 44-287 hr) where they were immobilized again...

  12. Water Metabolism of Walruses by Isotope Dilution

    DEFF Research Database (Denmark)

    Acquarone, M.; Born, E. W.; Chwalibog, A.;

    In August 2000, the hydrogen isotope dilution method was used on 7 adult male Atlantic walruses (Odobenus rosmarus rosmarus) (weight: 1197±148 kg, mean±SD, range 1013-1508 kg) at a terrestrial haul-out in Northeastern Greenland to determine their body water pool sizes and body water turnover rate...... successfully be used on walruses to estimate water metabolism as well as other metabolic parameters....

  13. Stable isotope dilution assays in mycotoxin analysis

    Energy Technology Data Exchange (ETDEWEB)

    Rychlik, Michael; Asam, Stefan [Universitaet Muenchen, Lehrstuhl fuer Lebensmittelchemie der Technischen, Garching (Germany)

    2008-01-15

    The principle and applications of stable isotope dilution assays (SIDAs) in mycotoxin analysis are critically reviewed. The general section includes historical aspects of SIDAs, the prerequisites and limitations of the use of stable isotopically labelled internal standards, and possible calibration procedures. In the application section actual SIDAs for the analysis of trichothecenes, zearalenone, fumonisins, patulin, and ochratoxin A are presented. The syntheses and availability of labelled mycotoxins for use as internal standards is reviewed and specific advances in food analysis and toxicology are demonstrated. The review indicates that LC-MS applications, in particular, require the use of stable isotopically labelled standards to compensate for losses during clean-up and for discrimination due to ion suppression. As the commercial availability of these compounds continues to increase, SIDAs can be expected to find expanding use in mycotoxin analysis. (orig.)

  14. Guideline on Isotope Dilution Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Gaffney, Amy [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-05-19

    Isotope dilution mass spectrometry is used to determine the concentration of an element of interest in a bulk sample. It is a destructive analysis technique that is applicable to a wide range of analytes and bulk sample types. With this method, a known amount of a rare isotope, or ‘spike’, of the element of interest is added to a known amount of sample. The element of interest is chemically purified from the bulk sample, the isotope ratio of the spiked sample is measured by mass spectrometry, and the concentration of the element of interest is calculated from this result. This method is widely used, although a mass spectrometer required for this analysis may be fairly expensive.

  15. Stable isotope dilution assays in mycotoxin analysis.

    Science.gov (United States)

    Rychlik, Michael; Asam, Stefan

    2008-01-01

    The principle and applications of stable isotope dilution assays (SIDAs) in mycotoxin analysis are critically reviewed. The general section includes historical aspects of SIDAs, the prerequisites and limitations of the use of stable isotopically labelled internal standards, and possible calibration procedures. In the application section actual SIDAs for the analysis of trichothecenes, zearalenone, fumonisins, patulin, and ochratoxin A are presented. The syntheses and availability of labelled mycotoxins for use as internal standards is reviewed and specific advances in food analysis and toxicology are demonstrated. The review indicates that LC-MS applications, in particular, require the use of stable isotopically labelled standards to compensate for losses during clean-up and for discrimination due to ion suppression. As the commercial availability of these compounds continues to increase, SIDAs can be expected to find expanding use in mycotoxin analysis.

  16. Isotope dilution analysis of polychlorinated biphenyls (PCBs) in transformer oil and global commercial PCB formulations by high resolution gas chromatography-high resolution mass spectrometry.

    Science.gov (United States)

    Takasuga, Takumi; Senthilkumar, Kurunthachalam; Matsumura, Tohru; Shiozaki, Ken; Sakai, Shin-ichi

    2006-01-01

    Special polychlorinated biphenyls (PCBs) standards (native and isotope labeled) were analyzed by isotope dilution method using HRGC-HRMS. Multiple analysis of special PCBs standards by three different laboratories produced the relative response factors (RRFs) and relative standard deviations (RSDs %) was in the average of 0.979 and 3.86, respectively. Additionally, inter-laboratory analysis of various forms of transformer oil revealed the PCBs concentrations were in the following order; PCBs fortified transformer oil (940-1300 ng/g)>PCB polluted transformer oil (490-680 ng/g)>chemically degraded-transformer oil (480-490 ng/g) and PCBs free oil (ND-17 ng/g). Chemical degradation resulted in an order of magnitude decrease in the PCB concentrations. Specifically, higher chlorinated PCBs degraded into lower chlorinated PCBs. Also, composition of PCBs have been determined in PCB formulations from Japan (Kanechlor), Germany (Clophen), USA (Aroclor), Russia (Sovol) and Poland (Chlorofen). Major PCBs (24-PCB congeners) contributed 54-67%, 55-68%, 16-69%, 71% and 72% in Kanechlor, Clophen, Aroclor, Sovol and Chlorofen, respectively to total PCBs. The homologue pattern of Kanechlor, Aroclor and Clophen in technical fromulation was similar (e.g., Kanechlor-300 resembled to those of Clophen A-30 and Aroclor-1242). Furthermore, congener-specific distributions of major PCBs/dioxin-like PCBs and toxic equivalency quantities (TEQ) were calculated. Based on our tentative assumption calculations, cumulative production of five different technical PCB formulations, WHO-TEQ emission was estimated to be approximately 16.05 tons.

  17. Determination of closantel and rafoxanide in animal tissues by online anionic mixed-mode solid-phase extraction followed by isotope dilution liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Lai, Shirley Sau Ling; Yeung, Hoi Sze; Lee, Wai On; Ho, Clare; Wong, Yiu Tung

    2011-06-01

    A rapid and high-throughput isotope dilution LC-MS/MS method with online sample pre-concentration and clean-up using anionic mixed-mode SPE was described for the determination of closantel and rafoxanide in edible bovine and ovine tissues. Tissue samples were extracted with acetonitrile and acetone mixture (60:40, v/v). Sample pre-concentration, clean-up and analysis were completed simultaneously with the online MAX SPE LC-MS/MS system. Closantel-(13) C(6) and rafoxanide-(13) C(6) were used as the internal standards to improve the precision of the method. The method was validated with edible ovine and bovine tissues (muscle, kidney and liver) fortified at three different levels. The accuracy and RSD were 86-106% and ≤14%, respectively. This high-throughput method was suitable for routine quantitative analysis of closantel and rafoxanide in food safety surveillance samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Phenylboronic Acid Solid Phase Extraction Cleanup and Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry for the Determination of Florfenicol Amine in Fish Muscles.

    Science.gov (United States)

    Sin, Della Wai-Mei; Ho, Clare; Wong, Yiu-Tung

    2015-01-01

    Florfenicol (FFC) residues in foods are regulated as the sum of florfenicol and its metabolites measured as florfenicol amine (FFA). An isotope dilution LC-MS/MS method utilizing phenylboronic acid (PBA) SPE cleanup is established for the accurate determination of FFA in fish muscles (i.e., salmon and tilapia) after acid catalyzed hydrolysis. Comparisons of the PBA SPE cleanup procedure with other cleanup procedures such as mixed-mode cationic (MCX) SPE and solid supported liquid-liquid extraction were performed. Quantification of FFA in fish muscles was accomplished by using matrix-matched calibration with FFA-D3 as the internal standard. The method was validated with FFA fortified fish muscles at three different levels (50, 100, and 200 μg/kg). Conversion of FFC to FFA by acid catalyzed hydrolysis was evaluated and found to be ≥88%. The recoveries of FFA in fish muscles at the three fortification levels ranged from 89 to 106%, and RSDs were ≤9% in all cases. The LOD values in salmon and tilapia muscles were 0.13 and 1.64 μg/kg, respectively. The LOQ values in salmon and tilapia muscles were 0.29 and 4.13 μg/kg, respectively. This method is suitable for the application in routine control of FFC in fishes according to its residue definition.

  19. Quantification of DNA damage products resulting from deamination, oxidation and reaction with products of lipid peroxidation by liquid chromatography isotope dilution tandem mass spectrometry

    Science.gov (United States)

    Taghizadeh, Koli; McFaline, Jose L.; Pang, Bo; Sullivan, Matthew; Dong, Min; Plummer, Elaine; Dedon, Peter C.

    2009-01-01

    The analysis of damage products as biomarkers of inflammation has been hampered by a poor understanding of the chemical biology of inflammation, the lack of sensitive analytical methods, and a focus on single chemicals as surrogates for inflammation. To overcome these problems, we developed a general and sensitive liquid chromatographic tandem mass spectrometry (LC/MS-MS) method to quantify, in a single DNA sample, the nucleoside forms of seven DNA lesions reflecting the range of chemistries associated with inflammation: 2′-deoxyuridine, 2′-deoxyxanthosine, and 2′-deoxyinosine from nitrosative deamination; 8-oxo-2′-deoxyguanosine from oxidation; and 1,N2-etheno-2′-deoxyguanosine, 1,N6-etheno-2′-deoxyadenosine, and 3,N4-etheno-2′-deoxycytidine arising from reaction of DNA with lipid peroxidation products. Using DNA purified from cells or tissues under conditions that minimize artifacts, individual nucleosides are purified by HPLC and quantified by isotope-dilution, electrospray ionization LC/MS-MS. The method can be applied to other DNA damage products and requires 4-6 days to complete depending upon the number of samples. PMID:18714297

  20. Determination of 1-methyl-1H-1,2,4-triazole in soils contaminated by rocket fuel using solid-phase microextraction, isotope dilution and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Yegemova, Saltanat; Bakaikina, Nadezhda V; Kenessov, Bulat; Koziel, Jacek A; Nauryzbayev, Mikhail

    2015-10-01

    Environmental monitoring of Central Kazakhstan territories where heavy space booster rockets land requires fast, efficient, and inexpensive analytical methods. The goal of this study was to develop a method for quantitation of the most stable transformation product of rocket fuel, i.e., highly toxic unsymmetrical dimethylhydrazine - 1-methyl-1H-1,2,4-triazole (MTA) in soils using solid-phase microextraction (SPME) in combination with gas chromatography-mass spectrometry. Quantitation of organic compounds in soil samples by SPME is complicated by a matrix effect. Thus, an isotope dilution method was chosen using deuterated analyte (1-(trideuteromethyl)-1H-1,2,4-triazole; MTA-d3) for matrix effect control. The work included study of the matrix effect, optimization of a sample equilibration stage (time and temperature) after spiking MTA-d3 and validation of the developed method. Soils of different type and water content showed an order of magnitude difference in SPME effectiveness of the analyte. Isotope dilution minimized matrix effects. However, proper equilibration of MTA-d3 in soil was required. Complete MTA-d3 equilibration at temperatures below 40°C was not observed. Increase of temperature to 60°C and 80°C enhanced equilibration reaching theoretical MTA/MTA-d3 response ratios after 13 and 3h, respectively. Recoveries of MTA depended on concentrations of spiked MTA-d3 during method validation. Lowest spiked MTA-d3 concentration (0.24 mg kg(-1)) provided best MTA recoveries (91-121%). Addition of excess water to soil sample prior to SPME increased equilibration rate, but it also decreased method sensitivity. Method detection limit depended on soil type, water content, and was always below 1 mg kg(-1). The newly developed method is fully automated, and requires much lower time, labor and financial resources compared to known methods.

  1. Stable isotope dilution analysis of orotic acid and uracil in amniotic fluid

    NARCIS (Netherlands)

    Jakobs, C.; Sweetman, L.; Nyhan, W.L.; Gruenke, L.; Craig, J.C.; Wadman, S.K.

    1984-01-01

    Rapid, sensitive and accurate stable isotope dilution assays were developed for the measurement of orotic acid and uracil in amniotic fluid. The method utilizes [15N2]orotic acid and [15N2]uracil as internal standards, isolation by liquid partition chromatography and quantitation by chemical ionizat

  2. Quantitation of the DNA Adduct of Semicarbazide in Organs of Semicarbazide-Treated Rats by Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry: A Comparative Study with the RNA Adduct.

    Science.gov (United States)

    Wang, Yinan; Wong, Tin-Yan; Chan, Wan

    2016-09-19

    Semicarbazide is a widespread food contaminant that is produced by multiple pathways. However, the toxicity of semicarbazide to human health remains unclear. Using a highly accurate and sensitive isotope-dilution liquid chromatography-tandem mass spectrometry method, we identified and quantitated in this study for the first time the DNA and RNA adduct of semicarbazide in DNA/RNA isolated from the internal organs of semicarbazide-exposed rats. The analysis revealed a dose-dependent formation of the adducts in the internal organs of the semicarbazide-dosed rats and with the highest adduct levels identified in the stomach and small intestine. Furthermore, results showed significantly higher levels of the RNA adduct (4.1-7.0 times) than that of the DNA adducts. By analyzing DNA/RNA samples isolated from rat organs in semicarbazide-dosed rats at different time points postdosing, the adduct stability in vivo was also investigated. These findings suggest that semicarbazide could have exerted its toxicity by affecting both the transcription and translation processes of the cell.

  3. Fast and solvent-free quantitation of boar taint odorants in pig fat by stable isotope dilution analysis-dynamic headspace-thermal desorption-gas chromatography/time-of-flight mass spectrometry.

    Science.gov (United States)

    Fischer, Jochen; Haas, Torsten; Leppert, Jan; Lammers, Peter Schulze; Horner, Gerhard; Wüst, Matthias; Boeker, Peter

    2014-09-01

    Boar taint is a specific off-odour of boar meat products, known to be caused by at least three unpleasant odorants, with very low odour thresholds. Androstenone is a boar pheromone produced in the testes, whereas skatole and indole originate from the microbial breakdown of tryptophan in the intestinal tract. A new procedure, applying stable isotope dilution analysis (SIDA) and dynamic headspace-thermal desorption-gas chromatography/time-of-flight mass spectrometry (dynHS-TD-GC/TOFMS) for the simultaneous quantitation of these boar taint compounds in pig fat was elaborated and validated in this paper. The new method is characterised by a simple and solvent-free dynamic headspace sampling. The deuterated compounds d3-androstenone, d3-skatole and d6-indole were used as internal standards to eliminate matrix effects. The method validation performed revealed low limits of detection (LOD) and quantitation (LOQ) with high accuracy and precision, thus confirming the feasibility of the new dynHS-TD-GC/TOFMS approach for routine analysis.

  4. Automated on-line column-switching high performance liquid chromatography isotope dilution tandem mass spectrometry method for the quantification of bisphenol A, bisphenol F, bisphenol S, and 11 other phenols in urine.

    Science.gov (United States)

    Zhou, Xiaoliu; Kramer, Joshua P; Calafat, Antonia M; Ye, Xiaoyun

    2014-01-01

    Human exposure to bisphenol A (BPA) is widespread. However, in recent years, bisphenol analogs such as bisphenol S (BPS) and bisphenol F (BPF) are replacing BPA in the production of some consumer products. Because human exposure to these alternative bisphenols may occur, biomonitoring of these bisphenol analogs is warranted. In the present study, we developed and validated a sensitive and selective method that uses on-line solid phase extraction coupled to high performance liquid chromatography-isotope dilution tandem mass spectrometry with peak focusing to measure BPA, BPF, BPS, and 11 other environmental phenols in urine. The method required a small amount of sample (100μL) and minimal sample pretreatment. The limits of detection were 0.03ng/mL (BPS), 0.06ng/mL (BPF), 0.10ng/mL (BPA), and ranged from 0.1ng/mL to 1.0ng/mL for the other 11 phenols. In 100 urine samples collected in 2009-2012 from a convenience group of anonymous adults in the United States, of the three bisphenols, we detected BPA at the highest frequency and median concentrations (95%, 0.72ng/mL), followed by BPS (78%, 0.13ng/mL) and BPF (55%, 0.08ng/mL). This sensitive, rugged, and labor and cost-effective method could be used for the analysis of large number of samples for epidemiologic studies.

  5. Simultaneous quantification of phencynonate and its active metabolite N-demethyl phencynonate in human plasma using liquid chromatography and isotope-dilution mass spectrometry.

    Science.gov (United States)

    Chen, Zhengang; Xie, Hui; Liu, Jinbo; Wang, Guangshun

    2015-09-01

    A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed to simultaneously quantify phencynonate (PCN) and its major metabolite N-demethyl phencynonate (DM-PCN) in human plasma. Following one-step liquid-liquid extraction, the analytes were separated on a reversed-phase C18 column. Methanol and 0.02% formic acid in 10 mM ammonium acetate (62:38, v/v) was used as isocratic mobile phase at a flow-rate of 0.3 mL/min. An API 5000 tandem mass spectrometer equipped with a Turbo IonSpray ionization source was used as the detector and was operated in the positive ion mode. Multiple reaction monitoring using the transition of m/z 358.4 → m/z 156.2, m/z 344.4 → m/z 142.2, and m/z 361.3 → m/z 159.2 was performed to quantify PCN, DM-PCN, and the internal standard (D3 -PCN), respectively. This approach showed a lower limit of quantification of 10 pg/mL and 25 pg/mL for PCN and DM-PCN in plasma, respectively. This sensitivity was at least 50-fold superior to previously reported ones and thus enabled the approach well applicable to low-dose pharmacokinetic studies. The intra- and inter-day precisions were less than 14.2 % at each QC level for both PCN and DM-PCN. The inter-day relative errors ranged from -1.9% to -4.9% for PCN, and from 0.6% to 6.4% for DM-PCN. As a proof of principle, the validated method was successfully applied to simultaneous quantification of circulating PCN and DM-PCN in healthy subjects after a single oral administration of 2 mg phencynonate hydrochloride pellet.

  6. Comprehensive profiling of mercapturic acid metabolites from dietary acrylamide as short-term exposure biomarkers for evaluation of toxicokinetics in rats and daily internal exposure in humans using isotope dilution ultra-high performance liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Yu; Wang, Qiao; Cheng, Jun; Zhang, Jingshun; Xu, Jiaojiao; Ren, Yiping

    2015-09-24

    Mercapturic acid metabolites from dietary acrylamide are important short-term exposure biomarkers for evaluating the in vivo toxicity of acrylamide. Most of studies have focused on the measurement of two metabolites, N-acetyl-S-(2-carbamoylethyl)-L-cysteine (AAMA) and N-acetyl-S-(2-carbamoyl-2-hydroxyethyl)-L-cysteine (GAMA). Thus, the comprehensive profile of acrylamide urinary metabolites cannot be fully understood. We developed an isotope dilution ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for the simultaneous determination of all four mercapturic acid adducts of acrylamide and its primary metabolite glycidamide under the electroscopy ionization negative (ESI-) mode in the present study. The limit of detection (LOD) and limit of quantification (LOQ) of the analytes ranged 0.1-0.3 ng/mL and 0.4-1.0 ng/mL, respectively. The recovery rates with low, intermediate and high spiking levels were calculated as 95.5%-105.4%, 98.2%-114.0% and 92.2%-108.9%, respectively. Acceptable within-laboratory reproducibility (RSDrats. Meanwhile, results of human urine analysis indicated that the levels of N-acetyl-S-(2-carbamoylethyl)-L-cysteine-sulfoxide (AAMA-sul), which did not appear in the mercapturic acid metabolites in rodents, were more than the sum of GAMA and N-acetyl-S-(1-carbamoyl-2-hydroxyethyl)-L-cysteine (iso-GAMA). Thus, AAMA-sul may alternatively become a specific biomarker for investigating the acrylamide exposure in humans. Current proposed method provides a substantial methodology support for comprehensive profiling of toxicokinetics and daily internal exposure evaluations of acrylamide in vivo.

  7. Simultaneous measurement of testosterone, androstenedione and dehydroepiandrosterone (DHEA) in serum and plasma using Isotope-Dilution 2-Dimension Ultra High Performance Liquid-Chromatography Tandem Mass Spectrometry (ID-LC-MS/MS).

    Science.gov (United States)

    Büttler, Rahel M; Martens, Frans; Kushnir, Mark M; Ackermans, Mariette T; Blankenstein, Marinus A; Heijboer, Annemieke C

    2015-01-01

    The adrenal and gonadal androgens, testosterone, androstenedione and dehydroepiandrosterone (DHEA) play an important role in sexual development as well as in other processes. We developed a method for simultaneous quantitative analysis of serum and plasma testosterone, androstenedione and DHEA levels using Isotope-Dilution Liquid-Chromatography Tandem Mass Spectrometry (ID-LC-MS/MS). Samples underwent liquid-liquid extraction and were analyzed on an Acquity 2D-UPLC-System and a Xevo TQ-S tandem mass spectrometer (Waters). The intra-assay and inter-assay coefficients of variation were DHEA, respectively. Inter-assay CVs at the lower limit were 10.6%, 16.9% and 9.0% for testosterone (0.10nmol/L), androstenedione (0.10nmol/L) and DHEA (1.0nmol/L), respectively. Recoveries of spiked analytes were 93-107%. The present testosterone method compared well (y=1.00x-0.04; r=0.998) to a published ID-LC-MS/MS method for testosterone in our lab. The latter method being concordant with a published reference method (Bui et al., 2013). The present method compared well to a published ID-LC-MS/MS method (Kushnir et al., 2010) (y=1.06x-0.06; r=0.996 for testosterone; y=1.04x-0.04; r=0.995 for androstenedione and y=1.03x+0.01; r=0.991 for DHEA). In conclusion, we developed a sensitive and accurate ID-LC-MS/MS method to simultaneously measure serum testosterone, androstenedione and DHEA in serum and plasma. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Development of a stable isotope dilution assay for tenuazonic acid.

    Science.gov (United States)

    Asam, Stefan; Liu, Yang; Konitzer, Katharina; Rychlik, Michael

    2011-04-13

    A stable isotope dilution assay (SIDA) for the Alternaria mycotoxin tenuazonic acid was developed. Therefore, [(13)C(6),(15)N]-tenuazonic acid was synthesized from [(13)C(6),(15)N]-isoleucine by Dieckmann intramolecular cyclization after acetoacetylation with diketene. The synthesized [(13)C(6),(15)N]-tenuazonic acid was used as the internal standard for determination of tenuazonic acid in tomato products by liquid chromatography tandem mass spectrometry after derivatization with 2,4-dinitrophenylhydrazine. Method validation revealed a limit of detection of 0.1 μg/kg and a limit of quantitation of 0.3 μg/kg. Recovery was close to 100% in the range of 3-300 μg/kg. Determination of tenuazonic acid in two samples of different tomato ketchups (naturally contaminated) was achieved with a coefficient of variation of 2.3% and 4.7%. Different tomato products (n = 16) were analyzed for their content of tenuazonic acid using the developed SIDA. Values were between 15 and 195 μg/kg (tomato ketchup, n = 9), 363 and 909 μg/kg (tomato paste, n = 2), and 8 and 247 μg/kg (pureed tomatoes and comparable products, n = 5).

  9. Comprehensive profiling of mercapturic acid metabolites from dietary acrylamide as short-term exposure biomarkers for evaluation of toxicokinetics in rats and daily internal exposure in humans using isotope dilution ultra-high performance liquid chromatography tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yu [Department of Food Science and Nutrition, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, Zhejiang (China); Zhejiang Key Laboratory for Agro-Food Processing, Zhejiang R & D Center for Food Technology and Equipment, Fuli Institute of Food Science, Zhejiang University, Hangzhou 310058, Zhejiang (China); Wang, Qiao; Cheng, Jun [Department of Food Science and Nutrition, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, Zhejiang (China); Zhang, Jingshun; Xu, Jiaojiao [Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051, Zhejiang (China); Ren, Yiping, E-mail: renyiping@263.net [Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051, Zhejiang (China)

    2015-09-24

    Mercapturic acid metabolites from dietary acrylamide are important short-term exposure biomarkers for evaluating the in vivo toxicity of acrylamide. Most of studies have focused on the measurement of two metabolites, N-acetyl-S-(2-carbamoylethyl)-L-cysteine (AAMA) and N-acetyl-S-(2-carbamoyl-2-hydroxyethyl)-L-cysteine (GAMA). Thus, the comprehensive profile of acrylamide urinary metabolites cannot be fully understood. We developed an isotope dilution ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for the simultaneous determination of all four mercapturic acid adducts of acrylamide and its primary metabolite glycidamide under the electroscopy ionization negative (ESI-) mode in the present study. The limit of detection (LOD) and limit of quantification (LOQ) of the analytes ranged 0.1–0.3 ng/mL and 0.4–1.0 ng/mL, respectively. The recovery rates with low, intermediate and high spiking levels were calculated as 95.5%–105.4%, 98.2%–114.0% and 92.2%–108.9%, respectively. Acceptable within-laboratory reproducibility (RSD < 7.0%) substantially supported the use of current method for robust analysis. Rapid pretreatment procedures and short run time (8 min per sample) ensured good efficiency of metabolism profiling, indicating a wide application for investigating short-term internal exposure of dietary acrylamide. Our proposed UHPLC-MS/MS method was successfully applied to the toxicokinetic study of acrylamide in rats. Meanwhile, results of human urine analysis indicated that the levels of N-acetyl-S-(2-carbamoylethyl)-L-cysteine-sulfoxide (AAMA-sul), which did not appear in the mercapturic acid metabolites in rodents, were more than the sum of GAMA and N-acetyl-S-(1-carbamoyl-2-hydroxyethyl)-L-cysteine (iso-GAMA). Thus, AAMA-sul may alternatively become a specific biomarker for investigating the acrylamide exposure in humans. Current proposed method provides a substantial methodology support for comprehensive

  10. Isotope dilution gamma spectrometry for Pu using low energy photons

    Energy Technology Data Exchange (ETDEWEB)

    Paul, S.; Sarkar, A.; Alamelu, D.; Shah, R.V.; Aggarwal, S.K. [Bhabha Atomic Reseach Centre, Mumbai (India). Fuel Chemistry Div.

    2012-07-01

    Isotope dilution gamma spectrometry (IDGS) for determination of the Pu concentration, using high resolution gamma-ray spectrometry (HRGS) in the 40-150 keV energy range, is developed and described. The methodology involves purification of Pu by an anion exchange procedure, followed by the determination of Pu isotopic composition using HRGS. For isotope dilution, a pre-calibrated power reactor grade Pu ({proportional_to} 70 at. % {sup 239}Pu) solution from an Indian PHWR was used as a spike for research reactor grade Pu ({proportional_to} 95 at. % {sup 239}Pu) samples and vice versa. Changes in {sup 240}Pu/{sup 239}Pu (45.24 keV/51.62 keV) and {sup 241}Pu/{sup 239}Pu (148.57 keV/129.29 keV) activity ratios in the spiked samples were determined by gamma spectrometry. Using the atom ratios calculated from the measured activity ratios, the concentration of Pu in the sample was calculated using two different efficiency calibration methods. The isotopic composition and concentration of Pu samples both from power reactor and research reactor grade agreed well with the values obtained by isotope dilution-thermal ionization mass spectrometry. The present method also shows the superiority of using the {sup 240}Pu/{sup 239}Pu atom ratio against the {sup 241}Pu/{sup 239}Pu atom ratio in IDGS with respect to the accuracy and precision. (orig.)

  11. Determination of acrylamide in Chinese traditional carbohydrate-rich foods using gas chromatography with micro-electron capture detector and isotope dilution liquid chromatography combined with electrospray ionization tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Yu [Department of Food Science and Nutrition, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310029, Zhejiang Province (China); Ren Yiping [Zhejiang Provincial Center for Disease Prevention and Control, Hangzhou 310009, Zhejiang Province (China); Zhao Hangmei [Department of Food Science and Nutrition, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310029, Zhejiang Province (China); Zhang Ying [Department of Food Science and Nutrition, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310029, Zhejiang Province (China)]. E-mail: y_zhang@zju.edu.cn

    2007-02-19

    The present study developed two analytical methods for quantification of acrylamide in complex food matrixes, such as Chinese traditional carbohydrate-rich foods. One is based on derivatization with potassium bromate and potassium bromide without clean-up prior to gas chromatography with micro-electron capture detector (GC-MECD). Alternatively, the underivatized acrylamide was detected by high-performance liquid chromatography coupled to quadrupole tandem mass spectrometry (HPLC-MS/MS) in the positive electrospray ionization mode. For both methods, the Chinese carbohydrate-rich samples were homogenized, defatted with petroleum ether and extracted with aqueous solution of sodium chloride. Recovery rates for acrylamide from spiked Chinese style foods with the spiking level of 50, 500 and 1000 {mu}g kg{sup -1} were in the range of 79-93% for the GC-MECD including derivatization and 84-97% for the HPLC-MS/MS method. Typical quantification limits of the HPLC-MSMS method were 4 {mu}g kg{sup -1} for acrylamide. The GC-MECD method achieved quantification limits of 10 {mu}g kg{sup -1} in Chinese style foods. Thirty-eight Chinese traditional foods purchased from different manufacturers were analyzed and compared with four Western style foods. Acrylamide contaminant was found in all of samples at the concentration up to 771.1 and 734.5 {mu}g kg{sup -1} detected by the GC and HPLC method, respectively. The concentrations determined with the two different quantitative methods corresponded well with each other. A convenient and fast pretreatment procedure will be optimized in order to satisfy further investigation of hundreds of samples.

  12. Determination of acrylamide in Chinese traditional carbohydrate-rich foods using gas chromatography with micro-electron capture detector and isotope dilution liquid chromatography combined with electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Yu; Ren, Yiping; Zhao, Hangmei; Zhang, Ying

    2007-02-19

    The present study developed two analytical methods for quantification of acrylamide in complex food matrixes, such as Chinese traditional carbohydrate-rich foods. One is based on derivatization with potassium bromate and potassium bromide without clean-up prior to gas chromatography with micro-electron capture detector (GC-MECD). Alternatively, the underivatized acrylamide was detected by high-performance liquid chromatography coupled to quadrupole tandem mass spectrometry (HPLC-MS/MS) in the positive electrospray ionization mode. For both methods, the Chinese carbohydrate-rich samples were homogenized, defatted with petroleum ether and extracted with aqueous solution of sodium chloride. Recovery rates for acrylamide from spiked Chinese style foods with the spiking level of 50, 500 and 1000 microg kg(-1) were in the range of 79-93% for the GC-MECD including derivatization and 84-97% for the HPLC-MS/MS method. Typical quantification limits of the HPLC-MSMS method were 4 microg kg(-1) for acrylamide. The GC-MECD method achieved quantification limits of 10 microg kg(-1) in Chinese style foods. Thirty-eight Chinese traditional foods purchased from different manufacturers were analyzed and compared with four Western style foods. Acrylamide contaminant was found in all of samples at the concentration up to 771.1 and 734.5 microg kg(-1) detected by the GC and HPLC method, respectively. The concentrations determined with the two different quantitative methods corresponded well with each other. A convenient and fast pretreatment procedure will be optimized in order to satisfy further investigation of hundreds of samples.

  13. Short course on St-02 applications of isotope dilutions and isotopic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Miller, P.

    1998-01-05

    This short course includes information on these topics and subtopics: (I) Nuclear Properties: (A) Historic roots; (B) Nomenclature; (C) Nuclear Stability and abundance; (D) Uses of isotopic techniques; (II) Instrumentation: (A) Sources; (B) Mass resolving elements; (C) Detectors; (III) Making Isotopic Measurements by ICP-MS: (A) Deadtime Correction; (B) Mass Discrimination; (C) Signal /Noise considerations; (IV) Applications and examples: (A) Isotope dilution; (B) Double Spike; (C) Biological Application; (D) Environmental Application; (E) Geological.

  14. 同位素稀释液相色谱串联质谱法测定血清甲状腺素%Serum total thyroxine measured by isotope dilution liquid chromatography tandem mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    周伟燕; 张江涛; 李铭; 张天娇; 曾洁; 赵海舰; 马嵘; 王冬环; 葛梦蕾

    2015-01-01

    目的 建立同位素稀释液相色谱串联质谱法(ID-LC/MS/MS)测定血清甲状腺素的候选参考方法.方法 实验性基础研究.重量法准确地称取血清或校准溶液,稀释器加入13C6-甲状腺素,混合,除去蛋白后经过阳离子交换固相萃取柱,收集洗脱液氮气吹干,复溶后用LC/MS/MS测定甲状腺素和内标.用7种混合血清评价方法的精密度;以其中一种血清为样本,分别向样本中加入原样本浓度50%、100%和200%的标准物质评价方法的加样回收率;分别以信噪比(S/N) >3和(S/N)>10作为标准,评价方法的检测限和定量限.分析德国临床化学会参考物质CRM 21201和CRM21202,评价方法的正确度.结果 血清甲状腺素测定的批内CV和总CV分别为0.64% (0.35% ~0.89%)和0.83%(0.57% ~1.37%).加样回收率为99.6% ~ 100.7%.检测限和定量限分别为0.12和0.41nmoL/L.分析CRM 21201和CRM 21202,测定结果与认定值的平均偏差为-0.30%(范围-0.13%~0.73%).结论 建立了ID-LC/MS/MS测定血清甲状腺素的方法,方法取样量少,测定结果正确、精密,可望作为血清甲状腺素测定的参考方法.%Objective An isotope dilution liquid chromatography tandem mass spectrometric (ID-LC/MS/MS) method was developed for serum total thyroxine.Methods Serum samples were sampled by weight and the 13C6-thyroxine internal standards were added volumetrically using automated dilutors,followed by equilibration,protein precipitation,and cation exchang solid-phase extractions (SPE).After SPE,the eluates were evaporated to dryness under nitrogen and then the evaporated residues were reconstituted to prepare samples for liquid chromatography-mass spectrometry electrospray ionization (LC/MS-ESI) analysis.Seven kinds of serum pools were used to analyze the precision of the method.The analytical recovery,the limit of detection(signal to noise ratio,S/N ratio 3∶1) and the limit of quantification (S/N ratio 10∶1

  15. Analysis of Cyanide in Blood by Headspace-Isotope-Dilution-GC-MS

    DEFF Research Database (Denmark)

    Løbger, Lise Lotte; Petersen, Henning Willads; Andersen, Jens Enevold Thaulov

    2008-01-01

    An uncomplicated, rapid, automated procedure for the analysis of low cyanide concentrations in whole blood is reported. The analysis was performed by headspace gas chromatography and mass spectrometry in the (1H12C14N) and m/z 29 (1H13C15N). Carryover from cyanide adsorption onto the surface...... of the needle was prevented by developing a new method that enabled automated flushing of the needle in between each cyanide analysis. Results were compared of ordinary calibrations and those of isotope dilutions. The total time of analysis was 18min for a single cyanide analysis....

  16. Trace determination of zinc by substoichiometric isotope dilution analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sandhya, D.; Priya, S.; Subramanian, M.O.S. [Indian Institute of Technology, Madras (India)

    1996-09-01

    A radiometric method based on substoichiometric isotope dilution analysis using 1,10-phenanthroline and a substoichiometric amount of eosin was developed for determining trace amounts of zinc. Evaluation of various metal ion interferences shows that as little as 0.2 {mu}g Zn could be determined in an aqueous-phase volume of 60 mL. The method has been successfully applied to the determination of Zn in city waste incineration ash, cadmium metal, Fourts-B tablets, Boro-plus ointment, and magnesium alloy samples. 12 refs., 3 figs., 3 tabs.

  17. A Collaborative Study: Determination of Mycotoxins in Corn, Peanut Butter, and Wheat Flour Using Stable Isotope Dilution Assay (SIDA) and Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS).

    Science.gov (United States)

    Zhang, Kai; Schaab, Matthew R; Southwood, Gavin; Tor, Elizabeth R; Aston, Linda S; Song, Wenlu; Eitzer, Brian; Majumdar, Sanghamitra; Lapainis, Theodore; Mai, Huy; Tran, Kevin; El-Demerdash, Aref; Vega, Victor; Cai, Yanxuan; Wong, Jon W; Krynitsky, Alexandra J; Begley, Timothy H

    2017-08-23

    A collaborative study was conducted to evaluate stable isotope dilution assay (SIDA) and LC-MS/MS for the simultaneous determination of aflatoxins B1, B2, G1, and G2; deoxynivalenol; fumonisins B1, B2, and B3; ochratoxin A; HT-2 toxin; T-2 toxin; and zearalenone in foods. Samples were fortified with 12 (13)C uniformly labeled mycotoxins ((13)C-IS) corresponding to the native mycotoxins and extracted with acetonitrile/water (50:50 v/v), followed by centrifugation, filtration, and LC-MS/MS analysis. In addition to certified reference materials, the six participating laboratories analyzed corn, peanut butter, and wheat flour fortified with the 12 mycotoxins at concentrations ranging from 1.0 to 1000 ng/g. Using their available LC-MS/MS platform, each laboratory developed in-house instrumental conditions for analysis. The majority of recoveries ranged from 80 to 120% with relative standard derivations (RSDs) <20%. Greater than 90% of the average recoveries of the participating laboratories were in the range of 90-110%, with repeatability RSDr (within laboratory) < 10% and reproducibility RSDR (among laboratory) < 15%. All Z scores of the results of certified reference materials were between -2 and 2. Using (13)C-IS eliminated the need for matrix-matched calibration standards for quantitation, simplified sample preparation, and achieved simultaneous identification and quantitation of multiple mycotoxins in a simple LC-MS/MS procedure.

  18. Measurement of isotope abundance variations in nature by gravimetric spiking isotope dilution analysis (GS-IDA).

    Science.gov (United States)

    Chew, Gina; Walczyk, Thomas

    2013-04-02

    Subtle variations in the isotopic composition of elements carry unique information about physical and chemical processes in nature and are now exploited widely in diverse areas of research. Reliable measurement of natural isotope abundance variations is among the biggest challenges in inorganic mass spectrometry as they are highly sensitive to methodological bias. For decades, double spiking of the sample with a mix of two stable isotopes has been considered the reference technique for measuring such variations both by multicollector-inductively coupled plasma mass spectrometry (MC-ICPMS) and multicollector-thermal ionization mass spectrometry (MC-TIMS). However, this technique can only be applied to elements having at least four stable isotopes. Here we present a novel approach that requires measurement of three isotope signals only and which is more robust than the conventional double spiking technique. This became possible by gravimetric mixing of the sample with an isotopic spike in different proportions and by applying principles of isotope dilution for data analysis (GS-IDA). The potential and principle use of the technique is demonstrated for Mg in human urine using MC-TIMS for isotopic analysis. Mg is an element inaccessible to double spiking methods as it consists of three stable isotopes only and shows great potential for metabolically induced isotope effects waiting to be explored.

  19. Combining the quick, easy, cheap, effective, rugged and safe approach and clean-up by immunoaffinity column for the analysis of 15 mycotoxins by isotope dilution liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Desmarchelier, Aurélien; Tessiot, Sabine; Bessaire, Thomas; Racault, Lucie; Fiorese, Elisa; Urbani, Alessandro; Chan, Wai-Chinn; Cheng, Pearly; Mottier, Pascal

    2014-04-11

    Optimization and validation of a multi-mycotoxin method by LC-MS/MS is presented. The method covers the EU-regulated mycotoxins (aflatoxins, fumonisins, ochratoxin A, deoxynivalenol, zearalenone, T-2 and HT-2), as well as nivalenol and 3- and 15-acetyldeoxynivalenol for analysis of cereals, cocoa, oil, spices, infant formula, coffee and nuts. The proposed procedure combines two clean-up strategies: First, a generic preparation suitable for all mycotoxins based on the QuEChERS (for quick, easy, cheap, effective, rugged and safe) protocol. Second, a specific clean-up devoted to aflatoxins and ochratoxin A using immunoaffinity column (IAC) clean-up. Positive identification of mycotoxins in matrix was conducted according to the confirmation criteria defined in EU Commission Decision 2002/657/EC while quantification was performed by isotopic dilution using (13)C-labeled mycotoxins as internal standards. Limits of quantification were at or below the maximum levels set in the EC/1886/2006 document for all mycotoxin/matrix combinations under regulation. In particular, the inclusion of an IAC step allowed achieving LOQs as low as 0.05 and 0.25μg/kg in cereals for aflatoxins and ochratoxin A, respectively. Other performance parameters like linearity [(r)(2)>0.99], recovery [71-118%], precision [(RSDr and RSDiR)<33%], and trueness [78-117%] were all compliant with the analytical requirements stipulated in the CEN/TR/16059 document. Method ruggedness was proved by a verification process conducted by another laboratory. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Quantification of Labile Soil Mercury by Stable Isotope Dilution Techniques

    Science.gov (United States)

    Shetaya, Waleed; Huang, Jen-How; Osterwalder, Stefan; Alewell, Christine

    2016-04-01

    Mercury (Hg) is a toxic element that can cause severe health problems to humans. Mercury is emitted to the atmosphere from both natural and anthropogenic sources and can be transported over long distances before it is deposited to aquatic and terrestrial environments. Aside from accumulation in soil solid phases, Hg deposited in soils may migrate to surface- and ground-water or enter the food chain, depending on its lability. There are many operationally-defined extraction methods proposed to quantify soil labile metals. However, these methods are by definition prone to inaccuracies such as non-selectivity, underestimation or overestimation of the labile metal pool. The isotopic dilution technique (ID) is currently the most promising method for discrimination between labile and non-labile metal fractions in soil with a minimum disturbance to soil-solid phases. ID assesses the reactive metal pool in soil by defining the fraction of metal both in solid and solution phases that is isotopically-exchangeable known as the 'E-value'. The 'E-value' represents the metal fraction in a dynamic equilibrium with the solution phase and is potentially accessible to plants. This is carried out by addition of an enriched metal isotope to soil suspensions and quantifying the fraction of metal that is able to freely exchange with the added isotope by measuring the equilibrium isotopic ratio by ICP-MS. E-value (mg kg-1) is then calculated as follows: E-Value = (Msoil/ W) (CspikeVspike/ Mspike) (Iso1IAspike -Iso2IAspikeRss / Iso2IAsoil Rss - Iso1IAsoil) where M is the average atomic mass of the metal in the soil or the spike, W is the mass of soil (kg), Cspike is the concentration of the metal in the spike (mg L-1), Vspike is the volume of spike (L), IA is isotopic abundance, and Rss is the equilibrium ratio of isotopic abundances (Iso1:Iso2). Isotopic dilution has been successfully applied to determine E-values for several elements. However, to our knowledge, this method has not yet

  1. A field survey of metal binding to metallothionein and other cytosolic ligands in liver of eels using an on-line isotope dilution method in combination with size exclusion (SE) high pressure liquid chromatography (HPLC) coupled to Inductively Coupled Plasma time-of-flight Mass Spectrometry (ICP-TOFMS).

    Science.gov (United States)

    Van Campenhout, Karen; Goenaga Infante, Heidi; Goemans, Geert; Belpaire, Claude; Adams, Freddy; Blust, Ronny; Bervoets, Lieven

    2008-05-15

    The effect of metal exposure on the accumulation and cytosolic speciation of metals in livers of wild populations of European eel with special emphasis on metallothioneins (MT) was studied. Four sampling sites in Flanders showing different degrees of heavy metal contamination were selected for this purpose. An on-line isotope dilution method in combination with size exclusion (SE) high pressure liquid chromatography (HPLC) coupled to Inductively Coupled Plasma time-of-flight Mass Spectrometry (ICP-TOFMS) was used to study the cytosolic speciation of the metals. The distribution of the metals Cd, Cu, Ni, Pb and Zn among cytosolic fractions displayed strong differences. The cytosolic concentration of Cd, Ni and Pb increased proportionally with the total liver levels. However, the cytosolic concentrations of Cu and Zn only increased above a certain liver tissue threshold level. Cd, Cu and Zn, but not Pb and Ni, were largely associated with the MT pool in correspondence with the environmental exposure and liver tissue concentrations. Most of the Pb and Ni and a considerable fraction of Cu and Zn, but not Cd, were associated to High Molecular Weight (HMW) fractions. The relative importance of the Cu and Zn in the HMW fraction decreased with increasing contamination levels while the MT pool became progressively more important. The close relationship between the cytosolic metal load and the total MT levels or the metals bound on the MT pool indicates that the metals, rather than other stress factors, are the major factor determining MT induction.

  2. Determination of Uranium and Plutonium Concentration in 1AF by Isotopic Dilution Mass Spectrometry Methods

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>It is important data to measure uranium and plutonium concentration for the reprocessing plant control analysis. The determination of uranium and plutonium concentration in 1AF by isotopic dilution mass

  3. Daily cortisol production rate in man determined by stable isotope dilution/mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Esteban, N.V.; Loughlin, T.; Yergey, A.L.; Zawadzki, J.K.; Booth, J.D.; Winterer, J.C.; Loriaux, D.L. (National Institute of Child Health and Human Development, Bethesda, MD (USA))

    1991-01-01

    Growth retardation as well as the development of Cushingoid features in adrenally insufficient patients treated with the currently accepted replacement dose of cortisol (33-41 mumol/day.m2; 12-15 mg/m2.day) prompted us to reevaluate the cortisol production rate (FPR) in normal subjects and patients with Cushing's syndrome, using a recently developed thermospray liquid chromatography-mass spectrometry method. The stable isotope (9,12,12-2H3)cortisol was infused continuously for 31 h at about 5% of the anticipated FPR. Blood samples were obtained at 20-min intervals for 24 h, spun, and pooled in 4-h groups. Tracer dilution in plasma was determined by liquid chromatography/mass spectrometry. The method was validated with controlled infusions in 6 patients with adrenal insufficiency. Results from 12 normal volunteers revealed a FPR of 27.3 +/- 7.5 mumol/day (9.9 +/- 2.7 mg/day) or 15.7 mumol/day.m2; 5.7 mg/m2. day. A previously unreported circadian variation in FPR was observed. Patients with Cushing's syndrome demonstrated unequivocal elevation of FPR and cortisol concentration correlated during each sample period in normal volunteers, indicating that cortisol secretion, rather than metabolism, is mainly responsible for changes in plasma cortisol. Our data suggest that the FPR in normal subjects may be lower than previously believed.

  4. Sulfur-based absolute quantification of proteins using isotope dilution inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Lee, Hyun-Seok; Heun Kim, Sook; Jeong, Ji-Seon; Lee, Yong-Moon; Yim, Yong-Hyeon

    2015-10-01

    An element-based reductive approach provides an effective means of realizing International System of Units (SI) traceability for high-purity biological standards. Here, we develop an absolute protein quantification method using double isotope dilution (ID) inductively coupled plasma mass spectrometry (ICP-MS) combined with microwave-assisted acid digestion for the first time. We validated the method and applied it to certify the candidate protein certified reference material (CRM) of human growth hormone (hGH). The concentration of hGH was determined by analysing the total amount of sulfur in hGH. Next, the size-exclusion chromatography method was used with ICP-MS to characterize and quantify sulfur-containing impurities. By subtracting the contribution of sulfur-containing impurities from the total sulfur content in the hGH CRM, we obtained a SI-traceable certification value. The quantification result obtained with the present method based on sulfur analysis was in excellent agreement with the result determined via a well-established protein quantification method based on amino acid analysis using conventional acid hydrolysis combined with an ID liquid chromatography-tandem mass spectrometry. The element-based protein quantification method developed here can be generally used for SI-traceable absolute quantification of proteins, especially pure-protein standards.

  5. An isotope-dilution standard GC/MS/MS method for steroid hormones in water

    Science.gov (United States)

    Foreman, William T.; Gray, James L.; ReVello, Rhiannon C.; Lindley, Chris E.; Losche, Scott A.

    2013-01-01

    An isotope-dilution quantification method was developed for 20 natural and synthetic steroid hormones and additional compounds in filtered and unfiltered water. Deuterium- or carbon-13-labeled isotope-dilution standards (IDSs) are added to the water sample, which is passed through an octadecylsilyl solid-phase extraction (SPE) disk. Following extract cleanup using Florisil SPE, method compounds are converted to trimethylsilyl derivatives and analyzed by gas chromatography with tandem mass spectrometry. Validation matrices included reagent water, wastewater-affected surface water, and primary (no biological treatment) and secondary wastewater effluent. Overall method recovery for all analytes in these matrices averaged 100%; with overall relative standard deviation of 28%. Mean recoveries of the 20 individual analytes for spiked reagent-water samples prepared along with field samples analyzed in 2009–2010 ranged from 84–104%, with relative standard deviations of 6–36%. Detection levels estimated using ASTM International’s D6091–07 procedure range from 0.4 to 4 ng/L for 17 analytes. Higher censoring levels of 100 ng/L for bisphenol A and 200 ng/L for cholesterol and 3-beta-coprostanol are used to prevent bias and false positives associated with the presence of these analytes in blanks. Absolute method recoveries of the IDSs provide sample-specific performance information and guide data reporting. Careful selection of labeled compounds for use as IDSs is important because both inexact IDS-analyte matches and deuterium label loss affect an IDS’s ability to emulate analyte performance. Six IDS compounds initially tested and applied in this method exhibited deuterium loss and are not used in the final method.

  6. Determination of tributyltin (TBT) in marine sediment using pressurised liquid extraction-gas chromatography-isotope dilution mass spectrometry (PLE-GC-IDMS) with a hexane-tropolone mixture.

    Science.gov (United States)

    Konieczka, Piotr; Sejerøe-Olsen, Berit; Linsinger, Thomas P J; Schimmel, Heinz

    2007-06-01

    Extraction conditions for the determination of tributyltin (TBT) in sediment samples have been developed further. The analytical procedure is based on spiking with isotopically labelled analyte, pressurised liquid extraction (PLE) with a hexane/tropolone mixture, Grignard derivatization and quantification by GC-MS. It was applied to two unknown sediment samples as part of an intercomparison exercise of the Comité Consultatif pour la Quantité de Matière (CCQM). The detection limit was approximately 1.5 ng/g TBT as Sn, while the repeatability and intermediate precision (as the coefficient of variation) were 1.9% and 3.2%, respectively. The expanded uncertainty was 6.2% (coverage factor k = 2), and the accuracy was confirmed by measurement of a certified reference material.

  7. Determination of plutonium isotopes in seawater reference materials using isotope-dilution ICP-MS.

    Science.gov (United States)

    Zheng, Jian; Yamada, Masatoshi

    2012-09-01

    We analyzed the activities of (239)Pu, (240)Pu, (239+240)Pu, (241)Pu, the ratio of number of atoms (atom ratio) for (240)Pu/(239)Pu, and the activity ratio of (241)Pu/(239+240)Pu in seawater reference materials, IAEA-443 and IAEA-381, using a highly sensitive isotope dilution sector field inductively coupled plasma mass spectrometry method. With a mean chemical yield of 65% determined with (242)Pu as a tracer, we found that the experimentally established values in IAEA-443 for (239)Pu, (240)Pu, (241)Pu and (239+240)Pu activities are almost the same as those in IAEA-381. Regarding the (239+240)Pu activity, we provided the most precise and accurate result among the twelve laboratories, which participated in the interlaboratory comparison. In addition, for the (240)Pu/(239)Pu atom ratio, our results for IAEA-381 (0.2315±0.0008) and IAEA-443 (0.2325±0.0008) are in good agreement with the IAEA information value (0.229±0.006), but have much smaller uncertainty. Since the new seawater reference material, IAEA-443, is commercially available, it can be used not only for method validation for seawater plutonium isotope ratio and activity analysis, but also for more general use as a plutonium isotope standard for mass discrimination correction for other environmental samples.

  8. Isotopic separation by ion chromatography; La separation isotopique par chromatographie ionique

    Energy Technology Data Exchange (ETDEWEB)

    Albert, M.G.; Barre, Y.; Neige, R. [CEA Centre d`Etudes de la Vallee du Rhone, 26 - Pierrelatte (France). Dept. de Technologie de l`Enrichissement

    1994-12-31

    The isotopic exchange reaction and the isotopic separation factor are first recalled; the principles of ion chromatography applied to lithium isotope separation are then reviewed (displacement chromatography) and the process is modelled in the view of dimensioning and optimizing the industrial process; the various dimensioning parameters are the isotopic separation factor, the isotopic exchange kinetics and the material flow rate. Effects of the resin type and structure are presented. Dimensioning is also affected by physico-chemical and hydraulic parameters. Industrial implementation features are also discussed. 1 fig., 1 tab., 5 refs.

  9. Single-run determination of polybrominated diphenyl ethers (PBDEs) di- to deca-brominated in fish meal, fish oil and fish feed by isotope dilution: Application of automated sample purification and gas chromatography/ion trap tandem mass spectrometry (GC/ITMS)

    Energy Technology Data Exchange (ETDEWEB)

    Blanco, Sonia Lucia, E-mail: lucia@anfaco.es [Centro Tecnico Nacional de Conservacion de Productos de la Pesca (ANFACO-CECOPESCA), Carretera Colexio Universitario No. 16, 36310, Vigo, Pontevedra (Spain); Vieites, Juan M. [Centro Tecnico Nacional de Conservacion de Productos de la Pesca (ANFACO-CECOPESCA), Carretera Colexio Universitario No. 16, 36310, Vigo, Pontevedra (Spain)

    2010-07-05

    The present paper describes the application of automated cleanup and fractionation procedures of the Power Prep system (Fluid Management Systems) for the determination of polybrominated diphenyl ethers (PBDEs) in feeding stuffs and fish meal and oil. Gas chromatography (GC) separation followed by ion trap tandem mass spectrometry detection in EI mode (ITMS) allowed the analysis of di- to deca-BDEs in the samples matrices used in fish aquaculture. The method developed enabled the determination of 26 native PBDE congeners and 11 {sup 13}C{sub 12}-labelled congeners, including deca-BDE 209, in a single-run analysis, using isotope dilution. The automated cleanup, consisting of a succession of multilayer silica and basic alumina columns previously applied by Wyrzykowska et al. (2009) in combustion flue gas, was succesfully applied in our complex matrices. The method allowed an increase in productivity, i.e. lower time was required to process samples, and simultaneous purification of several samples was achieved at a time, reducing analyst dedication and human error input. Average recoveries of 43-96% were obtained. GC/ITMS can overcome the complexity originating from the sample matrix, eliminating matrix effects by tandem MS, to enable the detection of congeners penta- to nona-BDEs where interferent masses were present. The provisional detection limits, estimated in the samples, were 5-30 pg for di-, tri-, tetra-, and penta-BDEs, 20-65 pg for hexa-, hepta-, octa- and nona-BDEs, and 105 pg for deca-BDE. Reduction of deca-BDE 209 blank values is of concern to ongoing research. Good accuracy was obtained by application of the whole procedure, representing an efficient, low-cost and fast alternative for routine analyses.

  10. Improvement of accuracy for the quantitation of selenoproteins in post-column isotope dilution technique with HPLC ICP/MS

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soo Jin; Pak, Yong Nam [Dept. of Chemistry Education, Korea National University of Education, Cheongju (Korea, Republic of)

    2016-11-15

    Post-column isotope dilution (PCID) or species-unspecific isotope dilution (ID) is a very useful quantitative technique in chromatography hyphenated with inductively coupled plasma–mass spectrometer (ICP/MS). In quantitative analysis, the calibration curve method is the most common one. However, it is not an absolute technique for the determination of concentration for the samples. ID method is the absolute one for the quantitative measurement technique, which means the quantity could be determined by the fundamental unit such as weight. To use the technique, it needs some requirements and there are several restrictions especially in the application for high-performance liquid chromatography (HPLC). The impurities in eluting solvent were in question. Thus, different purity of AA was examined and the result is shown in Figure 3. Figure 3(a) is the one for low (98%) and Figure 3(b) is high (99.999%) purity AA. The dotted area is for the eluting solvent. When low purity of 98% AA was introduced, the background was increasing while it remained the same for high-purity AA.

  11. Comparison of gas chromatography/isotope ratio mass spectrometry and liquid chromatography/isotope ratio mass spectrometry for carbon stable-isotope analysis of carbohydrates

    NARCIS (Netherlands)

    Moerdijk-Poortvliet, T.C.W.; Schierbeek, H.; Houtekamer, M.; van Engeland, T.; Derrien, D.; Stal, L.J.; Boschker, H.T.S.

    2015-01-01

    We compared gas chromatography/isotope ratio mass spectrometry (GC/IRMS) and liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) for the measurement of d13C values in carbohydrates. Contrary to GC/IRMS, no derivatisation is needed for LC/IRMS analysis of carbohydrates. Hence, although

  12. Determination of inositol 1,4,5-trisphosphate levels in Dictyostelium by isotope dilution assay

    Energy Technology Data Exchange (ETDEWEB)

    Van Haastert, P.J.

    1989-02-15

    A commercial isotope dilution assay was used for the determination of Ins(1,4,5)P3 levels in the microorganism Dictyostelium discoideum. Cross-reactivity in the assay was detected with extracts from cells and the medium. The compound which induced this cross-reactivity was tentatively identified as Ins(1,4,5)P3 by (i) codegradation with authentic (/sup 32/P)Ins(1,4,5)P3 by three specific Ins(1,4,5)P3 phosphatases, and (ii) co-chromatography with authentic (/sup 32/P)Ins(1,4,5)P3 on HPLC columns. The cellular concentration was estimated as 165 +/- 42 pmol/10(8) cells, yielding a mean intracellular Ins(1,4,5)P3 concentration of 3.3 microM. Dictyostelium cells secrete large amounts of Ins(1,4,5)P3 at a rate of about 10% of the cellular content per minute, yielding about 0.13 microM extracellular Ins(1,4,5)P3 after 15 min in a suspension of 10(8) cells/ml. The chemoattractant cAMP induced a transient increase of the Ins(1,4,5)P3 concentration; the data suggest an intracacellular rise from 3.3 to 5.5 microM with a maximum at 6 s after stimulation.

  13. An isotopic dilution approach for 1,3-butadiene tailpipe emissions and ambient air monitoring.

    Science.gov (United States)

    Riservato, Manuela; Rolla, Antonio; Davoli, Enrico

    2004-01-01

    An isotopic dilution approach for 1,3-butadiene analysis in gaseous samples is presented. The methodology is based on active sampling on sorbent tubes and subsequent analysis by thermal desorption into a gas chromatography/mass spectrometry system. By adding a perdeuterated internal standard onto the sorbent tubes before sampling, and using mass spectrometric detection, the methodology gives high accuracy for this unstable analyte. The method has been used to monitor 1,3-butadiene ambient air concentrations in a residential area in proximity to a heavy-traffic roadway over a one-week period, for comparison with other traffic-related pollutants analysed by standard procedures. It has also been used to determine tailpipe emissions of two vehicles by standard emission testing procedures in a dynamometer. These vehicles were chosen as examples of low- and high-end emission rate vehicles, i.e., an old no-catalytic converter Otto engine and a new direct-injection diesel engine with catalytic converter. Exhaust gas emissions were 0.052 and 35.85 mg/km, reflecting differences in fuel, engine design, age, and presence (or not) of a catalytic abatement system. The ambient air results showed a weekly average concentration of 1,3-butadiene of 0.53 microg/m(3).

  14. Stable isotope dilution analysis of hydrologic samples by inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Garbarino, J.R.; Taylor, H.E.

    1987-01-01

    Inductively coupled plasma mass spectrometry is employed in the determination of Ni, Cu, Sr, Cd, Ba, Ti, and Pb in nonsaline, natural water samples by stable isotope dilution analysis. Hydrologic samples were directly analyzed without any unusual pretreatment. Interference effects related to overlapping isobars, formation of metal oxide and multiply charged ions, and matrix composition were identified and suitable methods of correction evaluated. A comparability study snowed that single-element isotope dilution analysis was only marginally better than sequential multielement isotope dilution analysis. Accuracy and precision of the single-element method were determined on the basis of results obtained for standard reference materials. The instrumental technique was shown to be ideally suited for programs associated with certification of standard reference materials.

  15. Mercury speciation analysis in seafood by species-specific isotope dilution: method validation and occurrence data

    Energy Technology Data Exchange (ETDEWEB)

    Clemens, Stephanie; Guerin, Thierry [Agence Nationale de Securite Sanitaire de l' Alimentation, Laboratoire de Securite des Aliments de Maisons-Alfort, Unite des Contaminants Inorganiques et Mineraux de l' Environnement, ANSES, Maisons-Alfort (France); Monperrus, Mathilde; Donard, Olivier F.X.; Amouroux, David [IPREM UMR 5254 CNRS - Universite de Pau et des Pays de l' Adour, Laboratoire de Chimie Analytique Bio-Inorganique et Environnement, Institut des Sciences Analytiques et de Physico-chimie pour l' Environnement et les Materiaux, Pau Cedex (France)

    2011-11-15

    Methylmercury (MeHg) and total mercury (THg) in seafood were determined using species-specific isotope dilution analysis and gas chromatography combined with inductively coupled plasma mass spectrometry. Sample preparation methods (extraction and derivation step) were evaluated on certified reference materials using isotopically enriched Hg species. Solid-liquid extraction, derivation by propylation and automated agitation gave excellent accuracy and precision results. Satisfactory figures of merit for the selected method were obtained in terms of limit of quantification (1.2 {mu}g Hg kg{sup -1} for MeHg and 1.4 {mu}g Hg kg{sup -1} for THg), repeatability (1.3-1.7%), intermediate precision reproducibility (1.5% for MeHg and 2.2% for THg) and trueness (bias error less than 7%). By means of a recent strategy based on accuracy profiles ({beta}-expectation tolerance intervals), the selected method was successfully validated in the range of approximately 0.15-5.1 mg kg{sup -1} for MeHg and 0.27-5.2 mg kg{sup -1} for THg. Probability {beta} was set to 95% and the acceptability limits to {+-}15%. The method was then applied to 62 seafood samples representative of consumption in the French population. The MeHg concentrations were generally low (1.9-588 {mu}g kg{sup -1}), and the percentage of MeHg varied from 28% to 98% in shellfish and from 84% to 97% in fish. For all real samples tested, methylation and demethylation reactions were not significant, except in one oyster sample. The method presented here could be used for monitoring food contamination by MeHg and inorganic Hg in the future to more accurately assess human exposure. (orig.)

  16. Quantification of ferritin bound iron in human serum using species-specific isotope dilution mass spectrometry.

    Science.gov (United States)

    Ren, Yao; Walczyk, Thomas

    2014-09-01

    Ferritin is a hollow sphere protein composed of 24 subunits that can store up to 4500 iron atoms in its inner cavity. It is mainly found in the liver and spleen but also in serum at trace levels. Serum ferritin is considered as the best single indicator in assessing body iron stores except liver or bone marrow biopsy. However, it is confounded by other disease conditions. Ferritin bound iron (FBI) and ferritin saturation have been suggested as more robust biomarkers. The current techniques for FBI determination are limited by low antibody specificity, low instrument sensitivity and possible analyte losses during sample preparation. The need for a highly sensitive and reliable method is widely recognized. Here we describe a novel technique to detect serum FBI using species-specific isotope dilution mass spectrometry (SS-IDMS). [(57)Fe]-ferritin was produced by biosynthesis and in vitro labeling with the (57)Fe spike in the form of [(57)Fe]-citrate after cell lysis and heat treatment. [(57)Fe]-ferritin for sample spiking was further purified by fast liquid protein chromatography. Serum ferritin and added [(57)Fe]-ferritin were separated from other iron species by ultrafiltration followed by isotopic analysis of FBI using negative thermal ionization mass spectrometry. Repeatability of our assay is 8% with an absolute detection limit of 18 ng FBI in the sample. As compared to other speciation techniques, SS-IDMS offers maximum control over sample losses and species conversion during analysis. The described technique may therefore serve as a reference technique for clinical applications of FBI as a new biomarker for assessing body iron status.

  17. 稳定同位素稀释气相色谱-质谱联用测定化妆品中5种磷酸三酯类化合物%Determination of Organophosphate Esters in Cosmetics by Stable Isotope Dilution-Gas Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    韩婉清; 罗海英; 陈立伟; 吴玉銮; 冼燕萍; 王斌

    2014-01-01

    根据不同化妆品的基质特性探讨优化不同的提取净化方法,建立了稳定同位素稀释气相色谱-质谱联用测定化妆品中5种磷酸三酯类化合物( OPEs)的方法。膏霜乳液类和蜡基类化妆品经溶剂提取后,采用ENVI-Carb固相萃取柱净化;粉剂类和水剂类化妆品经溶剂提取、浓缩后直接检测。样液经DB-5MS(30 m×0.25 mm×0.25μm)色谱柱分离,GC-MS的选择离子监测( SIM)模式检测,以保留时间和特征离子丰度比定性,稳定同位素稀释内标法定量。在优化的实验条件下,5种磷酸三酯类化合物在各自的线性范围内相关系数大于0.9995,方法检出限为1.0~30μg/kg,平均回收率为89.5%~105%,相对标准偏差(n=6)为2.9%~9.1%。本方法净化效果好,可有效消除基质效应,且有较好的回收率,可用于不同类型的化妆品基质中磷酸三酯类化合物的测定。%A method based on stable isotope dilution gas chromatography-mass spectrometry ( GC-MS ) was established to determine five kinds of organophosphate esters ( OPEs ) in different kinds of cosmetics. For cream and wax-based cosmetics, samples were extracted by appropriate solvent, and then purified by ENVI-Carb solid phase extracting column. For powder and aqueous samples, GC-MS test could be operated directly after solvent extraction and concentration. All of the samples were separated by DB-5MS (30 m×0. 25 mm× 0. 25 μm) chromatographic column, and detected by selected ion monitoring ( SIM ) mode. The target analytes were qualitatively confirmed by retention time and abundance ratio of characteristic ions, and quantified by stable isotope diluted internal standard method. Under the optimized conditions, the linear coefficients of the OPEs were larger than 0. 9995, the detection limits were 1. 0-30 μg/kg, the average recoveries ( n=6 ) ranged from 89 . 5% to 105%, and the RSDs were in the range of 2 . 9%-9 . 1%. The developed method, which was characteristic by

  18. Determination of lnositol 1,4,5-Trisphosphate Levels in Dictyostelium by Isotope Dilution Assay

    NARCIS (Netherlands)

    Haastert, Peter J.M. van

    1989-01-01

    A commercial isotope dilution assay was used for the determination of Ins(1,4,5)P3 levels in the microorganism Dictyostelium discoideum. Cross-reactivity in the assay was detected with extracts from cells and the medium. The compound which induced this cross-reactivity was tentatively identified as

  19. Isotopic Dilution Analysis and Secular Equilibrium Study: Two Complementary Radiochemistry Experiments.

    Science.gov (United States)

    Williams, Kathryn R.; Lipford, Levin C.

    1985-01-01

    Describes a complementary pair of radiochemistry experiments for instruction of isotopic dilution analysis and secular equilibrium. Both experiments use the readily available cesium-137 nuclide and the simple precipitation technique for cesium with the tetraphenylborate anion. Procedures used and typical results obtained are provided and…

  20. Simultaneous analysis of folic acid and pantothenic acid in foods enriched with vitamins by stable isotope dilution assays

    Energy Technology Data Exchange (ETDEWEB)

    Rychlik, Michael

    2003-10-24

    Folic and pantothenic acid were quantified in multivitamin products by stable isotope dilution assays using [{sup 2}H{sub 4}]folic acid and [{sup 13}C{sub 3},{sup 15}N]pantothenic acid as the internal standards. Detection was achieved by liquid chromatography/mass spectrometry which enabled unequivocal determination of the vitamins. Due to the very simple extraction procedure, analysis of the vitamins was completed within 2 h. When analyzing multivitamin sweets, the intra-assay and inter-assay coefficient of variation was 3.2% (n=5) and 3.1% (n=5) for folic acid and 4.5% (n=5) as well as 6.5% (n=7) for pantothenic acid, respectively. Along with the precision data, recovery values of 99.4% for folic acid and 103% for pantothenic acid at addition levels of 6 mg/kg and 600 {mu}g/kg, respectively, to starch products proved the accuracy of the new method. Application of the stable isotope dilution assay to fruit juices, whey products, cereals, sweets, pharmaceuticals, wheat flour and salt fortified with one or both vitamins revealed that for the majority of products the labeled pantothenic acid contents were exceeded by about 30%, whereas for folic acid also significantly lower contents than the label claim were found.

  1. Determination of residues of chloramphenicol, thiamphenicol and florfenicol in shrimp by isotope dilution liquid and chromatography tandem mass spectrometry%同位素内标稀释液相色谱-串联质谱法测定虾中氯霉素、甲砜霉素和氟甲砜霉素残留量

    Institute of Scientific and Technical Information of China (English)

    陈剑刚; 张艳; 白艳玲; 冯翠霞; 梁素丹

    2013-01-01

    目的:建立了虾中氯霉素、甲砜霉素、氟甲砜霉素三种氯霉素类药物残留的同位素稀释高效液相色谱-串联质谱测定方法.方法:以氘代氯霉素(CAP-d5)为内标,样品用乙腈提取,正己烷脱脂,LC-Si硅胶柱净化,丙酮-正己烷洗(6+4)洗脱后吹氮浓缩.采用Atlantis(R)T3质谱柱分离,以乙腈-水-乙酸铵溶液为流动相进行梯度洗脱,以负离子多反应监测模式、同位素内标法定量.结果:方法的检出限和定量限分别为0.03 μg/kg、0.10 μg/kg;氯霉素、甲砜霉素、氟甲砜霉素回收率分别为82.0% ~ 99.3%、73.5% ~85.6%、76.0% ~ 98.5%;相对标准偏差为4.0%-12.5%.应用建立的方法对90份虾样进行分析,其中3份检出氯霉素,含量为1.0 μg/kg ~ 4.3 μg/kg.结论:本法具有非常高的选择性、灵敏度和准确度,完全能满足虾中痕量氯霉素类药物残留的高灵敏分析.%Objective:The method for the determination of three chloramphicols including chloramphenicol (CAP),thiamphenicol(TAP) and florfenicol(FF) in shrimp was developed by isotope dilution liquid and chromatography tandem Mass Spectrometry (LC-MS/MS).Methods:With chloramphenicol-d5 (CAP-d5) as internal standard,samples were extracted with acetonitrile,defatted with hexane,cleaned through LC-Si solid-phase column,eluted with acetone-hexane (6 + 4),evaporated by nitrogen gas to nearly dry.The extract components were separated completely on a Atlantis (R) T3 column with acetonitrile-water-10mmol.Lammonium acetate for gradient elution and simultaneously quantified by the isotope internal standard under the negative ion mode using multiple reactions monitoring mode.Results:The limits of detection for CAP,TAP and FF were the same as 0.03 μg/kg,and the limit of quantification were 0.10 μg/kg.The average recoveries of CAP,TAP and FF for spiked blank sample were 82.0% ~ 99.3%,73.5% ~ 85.6%,76.0% ~ 98.5% respectiVely,and their relative

  2. Determination of Typical Odorous Compounds in Water Using Purge-and-trap Gas Chromatography-Mass Spectrometry Combined with Stable Isotope Dilution%稳定性同位素稀释吹扫捕集-气质联用法测定水中典型臭味物质

    Institute of Scientific and Technical Information of China (English)

    许冬梅; 许俊鸽; 苑宝玲; 吕华东; 林麒

    2011-01-01

    A stable isotope dilution technique based on purge-and-trap coupled to gas chromatography with mass spectrometric detection was developed and optimized for the trace determination of the typical odorous compounds, geosmin (GSM) and 2-methylisoborneol (MIB). The selection of quantitation ions and the factors of temperature program, the sample purge temperature, salt content on the extraction of odorous compounds were studied. Under the experimental conditions, the optimal operating conditions were the addition of 20% (m/V) NaC1, purging at 60 ℃ on the temperature program of 5 ℃/min. D5-Geosmin and d3-MIB as the isotopes internal standards were added to improve the stability of recovery. Using this method, both the calibration curves of MIB and GSM were good linear correlation in the range of 5-500 ng/L. Recoveries were 82 %-95 % for GSM and 99%-101% for MIB, and precision was 5.2% for GSM and 0.8% for MIB. The limits of detection for GSM and MIB were 3.6 and 4.1 ng/L, respectively.%采用稳定性同位素稀释吹扫捕集-气相色谱/质谱联用法测定水中典型臭味物质土臭素(GSM)和2-甲基异莰醇(MIB).研究了特征离子、升温程序、样品吹扫温度及盐浓度等因素对臭味物质萃取过程的影响.本实验测定臭味物质的最佳条件为:盐浓度20%(m/V),样品吹扫温度60℃,程序升温速率5℃/min.通过加人同位素内标d5-GSM和d3-MIB,可以提高样品回收率的稳定性.土臭素(GSM)和2-甲基异莰醇(MIB)浓度在5~500 ng/L,范围内线性良好;在100 ng/L加标浓度水平下,GSM和MIB回收率范围分别为82%~95%和99%~101%;相对标准偏差为5.20%和0.78%.方法检出限分别为3.60和4.12 ng/L.本方法操作简单、快速、准确,用于实际水样的检测效果良好.

  3. Analysis of uranium isotope separation by redox chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Fujine, S.; Naruse, Y.; Shiba, K.

    1983-09-01

    Uranium isotope separation by redox chromatography is analytically studied. The periodic withdrawal of products and tails and the introduction of natural feed are simulated on the assumption of a square cascade for a uranium adsorption band. The influences on the separative power and the lead time until product withdrawal are investigated by varying the magnitude of the isotope separation factor, uranium band length, tails concentration, and so on. Simulating calculations indicate that using ion-exchange resins to achieve uranium isotope separation requires a very long lead time for the production of highly enriched uranium.

  4. Determination of total cyanide in soil by isotope dilution GC/MS following pentafluorobenzyl derivatization.

    Science.gov (United States)

    Campanella, Beatrice; Biancalana, Lorenzo; D'Ulivo, Lucia; Onor, Massimo; Bramanti, Emilia; Mester, Zoltan; Pagliano, Enea

    2017-04-08

    The high toxicity of cyanide, along with its widespread industrial use, has fuelled interest in the development of analytical methods for its determination in complex matrices. In this study, we propose a novel approach for the measurement of total cyanide in soil samples based on single-step derivatization with pentafluorobenzyl bromide (F5Bn-Br) followed by quantitation with gas chromatography mass spectrometry in negative chemical ionization mode. The reaction between CN(-) and F5Bn-Br resulted in the identification of several derivatives such as F5Bn-CN, (F5Bn)(F5Ph)CH-CN, and (F5Bn)2(F5Ph)C-CN. The relative proportion between such compounds was dependent on experimental conditions. When a 100 μL aliquot of an alkaline-aqueous extract was reacted with 700 μL of 1.3% F5Bn-Br in acetone, the tri-alkylated derivative was the most abundant. In such conditions a detection limit of 0.5 ng/g of CN(-) was attained. Soil samples were initially spiked with an alkaline solution of K(13)C(15)N internal standard and suspended in 7.5% aqueous NaOH. Determination of total cyanide was achieved by digestion of the alkaline extract with H3PO4 to produce HCN which was then trapped in 0.1% NaOH in a sealed double vial system, followed by reaction with F5Bn-Br. Isotope dilution calibration was chosen for quantitation, and the validity of the novel method was demonstrated by analysis of soil Certified Reference Materials (CRMs) and by spike recovery tests.

  5. Measurement of Infinite Diluted Activity Coefficient of Solvents in Polymer by Inverse Gas Chromatography Method

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    @@1 INTRODUCTION Due to its short experimental time, little sample needed, suitable for broad temperature range, inverse gas chromatography (IGC) has been widely used to measure variety of properties of polymer systems, such as the intinite diluted activity coefficients of solvent in polymer, the glass transition temperature of polymer and the surface properties of polymer[1-5], etc. Those data have been used to develop the group contribution method for the prediction of thermodynamic proper-ties of polymer solution[6].

  6. In vivo synthesized 34S enriched amino acid standards for species specific isotope dilution of proteins

    DEFF Research Database (Denmark)

    Hermann, Gerrit; Moller, Laura Hyrup; Gammelgaard, Bente

    2016-01-01

    A generic quantification approach was introduced addressing the characterization of protein standards while fulfilling the principles of metrology. Traceable absolute quantification was achieved combining a proven biochemical method, i.e. protein hydrolysis followed by amino acid quantification...... in yeast fermentations provided species specific isotopically enriched standards for IDA quantification of cysteine and methionine in the oxidized forms, methionine sulfone and cysteic acid. Reverse isotope dilution mass spectrometry (IDMS) characterization by inductively coupled plasma mass spectrometry...... and methionine sulfone, respectively, was assessed. The established IDA method was validated for the absolute quantification of commercially available lysozyme and ceruloplasmin standards including the calculation of a total combined uncertainty budget....

  7. Determination of Vitamin D in Infant Milk Powder by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry with Isotopes Dilution%同位素稀释-超高效液相色谱-串联质谱技术分析婴儿配方奶粉中的维生素D

    Institute of Scientific and Technical Information of China (English)

    曹慧; 陈小珍; 王瑾; 陈万勤

    2012-01-01

    In order to establish a reliable method for quantitative analysis of vitamin D in infant milk powder, a ultra performance liquid chromatography-tandem mass spectrometry (UPLC/MS/MS) with isotopes dilution method was developed. The samples were sapon-ifed with KOH and extracted by pentane-ethyl ether solution (V(pentane):V(ethyl ether) = 4:1). The target analytes were separated on the Waters T3 column with gradient elution using methanol and water (containing 2 mmol/L ammonium formate for both) as mobile phase. The identification and quantification were achieved by using electrospray ionization in positive ion mode and with multiple reaction monitoring. Internal standard method was used to determine the results. The linear range of the calibration curve was 5-150 /μg/L. The limit of detection (LOD) of the method was 1. 5μg/kg, and the limit of quantitation (LOQ) was 5. 0μg/kg. The recoveries of the method were in the range of 97. 0% -104. 7% and 92. 7%-108. 0% for vitamin D2 and vitamin D3 respectively. The relative standard deviations (RSD) of intra-day and inter-day were less than 10%. The simply, rapid, accurate and sensitive method can be applied to determine the vitamin D in infant milk powder.%为了准确测定婴儿配方奶粉中维生素D的含量,建立了同位素稀释-超高效液相色谱-串联质谱联用技术分析维生素D含量的方法.样品经氢氧化钾皂化,用V(正戊烷)∶V(乙醚)=4∶1的混合溶液提取,采用Waters T3色谱柱分离,以2 mmol/L甲酸铵-甲醇和2 mmol/L甲酸铵-水溶液为流动相进行梯度洗脱,采用电喷雾-正离子电离源多反应监测模式进行定性和定量分析,内标法定量.维生素D2和维生素D3在5~150 μg/L质量浓度范围内线性关系良好,维生素D2和维生素D3的检出限均为1.5 μg/kg,定量限均为5.0μg/kg,方法回收率分别为97.0%~104.7%和92.7%~108.0%,日内和日间相对标准偏差均小于10%.该方法简单、灵敏度高、分析时

  8. Isotope Dilution-Ultra Performance Liquid Chromatography Tandem Mass Spectrometry Method for the Detection of Plasma Cortisol%同位素稀释-超高效液相色谱串联质谱法检测血浆中的皮质醇

    Institute of Scientific and Technical Information of China (English)

    邓卫武; 陈雄云; 雷志红

    2015-01-01

    目的:建立一种同位素稀释-超高效液相色谱串联质谱法检测血浆中的皮质醇。方法:使用C18固相抽提小柱纯化、富集人体血浆中的总皮质醇。采用LC/MS/MS-ESI法分析血浆中的皮质醇含量。梯度流动相为0 min,50%甲醇;3 min,90%甲醇;3.5 min 90%甲醇;3.6min 50%甲醇;5 min 50%甲醇。水相含0.2%甲酸。MRM检测模式选择性监测cortisol(m/z363.2/121.4)、内标cortisol-d4(m/z367.4/121.4)。结果:血浆中加入梯度标准品的加标回收率分别为102.5%,101.1%,103.3%。检测冻存血浆中皮质醇的实验里,组内变异为0.54%~2.47%,组间变异为0.96%~1.69%,线性相关系数为R2≥0.999。LC/MS/MS信噪比为10时检出限为12pg。结论:该方法具有良好的特异性、灵敏度、精密度,能够准确的检测血浆中总皮质醇含量,为实现皮质醇溯源打下基础。%Objective:To establish a stable isotope dilution-ultra performance liquid chromatography tandem mass spectrometry method for the detection of plasma cortisol. Methods:Total cortisol concentration in human plasma and purification, using C18 solid phase extraction column. Cortisol concentrations in plasma were analyzed by using LC/MS/MS-ESI method. A gradient mobile phase was 0 min, 3 min, 50%methanol, 90%methanol;methanol;3.5 min 90%3.6min 50%;5 min 50%of methanol;methanol. The aqueous phase containing 0.2% formic acid. MRM detection mode selective monitoring of cortisol (m/z363.2/121.4) cortisol-d4 (m/z367.4/121.4), the internal standard. Results:The recovery of added standard gradient in plasma was respectively 102.5%, 101.1%, 103.3%. Detection of plasma cortisol in freezing experiment, within group variation is 0.54%~2.47%, 0.96%~1.69%between group variation, linear correlation coefficient is R2=0.999. LC/MS/MS signal to noise ratio is 10, the detection limit is 12pg. Conclusion:The method has good specificity, sensitivity, precision, detection of plasma total cortisol

  9. Determination of toxaphene in food by isotope dilution high resolution gas chromatography/high resolution mass spectrometry%同位素稀释-气相色谱/高分辨质谱法测定食品中的指示性毒杀芬

    Institute of Scientific and Technical Information of China (English)

    刘志斌; 张建清; 蒋友胜; 周健; 李胜浓; 陆少游; 林晓仕

    2014-01-01

    目的:建立食品样品中P26, P50, P62等三大指示性毒杀芬的检测分析方法,为进一步开展常规监测提供技术平台和基础数据。方法食品样品使用索式提取系统(Soxtec)提取,提取液依次由30%酸性硅胶柱和氧化铝柱净化,利用同位素稀释-高分辨气相色谱/高分辨双聚焦磁式质谱联用(ID-HRGC/HRMS)技术对三种指示性毒杀芬单体P26, P50, P62进行定量定性分析。结果本研究所建成的检测方法相对标准偏差(RSD)小于25%,回收率可以达到40%~120%;P26, P50, P62的方法检测限分别为0.08、0.02、0.06 pg/g;方法性能达到开展食品样品中毒杀芬检测技术的要求。结论该方法可以对食品样品中毒杀芬进行检测,检测效率高,结果准确可靠。%Objectives To develop the analyzing methods of 3 indicator toxaphenes (P26, P50 and P62) in food samples, so as to provide technical platform and basic data for further routine monitoring. Methods The food sample was extracted by using Soxtec followed by purification on 30%multilayer acidic silica column and neutral aluminum oxides column, utilizing isotope dilution high-resolution gas chromatography/high-resolution double-focusing magnetic mass spectrometry (HRGC/HRMS) to carry out quantitative and qualitative analysis on toxaphene monomer P26, P50, and P62. Results The developed analytical method for three indicator tox-aphenes monomer was built successfully, and suitable for the determination of toxaphene specific congeners in food. The relative standard deviation (RSD) was below 25% and the spiked recoveries were in the range of 40%~120%. The five point calibration curves showed a good linearity for all the congeners (R2>0.99). Method detection limit (MDL) was 0.08, 0.02, and 0.06 pg/g for P26, P50, and P62, respectively. Conclusion Three congeners of toxaphene can be measured simultaneously in food sample matrix, the method is efficient and the results are accurate and reliable.

  10. 同位素稀释气相色谱-质谱联用法监测芥子气染毒家兔尿液中的硫二甘醇%Monitoring Urine Thiodiglycol after Rabbit Skin Exposure to Sulfur Mustard Based on Highly-sensitive Isotope Dilution Gas Chromatography-Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    聂志勇; 张雅姣; 吴弼东; 闫珑; 冯建林; 刘勤; 谢剑炜

    2014-01-01

    A sensitive determination method for sulfur mustard ( HD ) metabolites thiodiglycol ( TDG ) in rabbit urine was established and validated using isotope dilution negative ion chemical ionization ( NICI) gas chromatography-mass spectrometry ( GC-MS ) , in which deuterated thiodiglycol ( TDG-d8 ) was used as internal standard. Two solid-phase extraction ( SPE) steps were established and optimized in order to reduce the interfering backgrounds, one was used to extract thiodiglycol ( TDG ) from urine with self-assemblied Florisil SPE cartridges, another cleaning treatment of the by-products after pentafluorobenzoyl chloride (PFBZ) derivatization. The results showed that the limits of detection quantitation of this method were 0. 1 and 0. 3 μg/L, respectively. The exposure time-response relationship and exposure dose-response relationship of TDG in rabbit urine were studied after rabbit skin exposure to sulfur mustard (HD, 0. 02-0. 15 LD50). The TDG levels in the rabbit urine increased rapidly during the first day after application and then decreased over time for all dosage groups. A secondary release was also noted for the high-dose group, and the duration of high TDG excretion levels was correlated positively with the HD dosage levels. We thus concluded that abnormally high levels of TDG in urine could be used as a clear diagnostic indicator of HD exposure.%以硫二甘醇( TDG)的八氘代同位素( TDG-d8)为内标,采用自制Florisil固相萃取( SPE)柱提取尿样中的TDG,用五氟苯甲酰氯( PFBZ)衍生化后,再经SPE净化富集,通过考察优化两步固相萃取( SPE)等前处理步骤,建立了尿液中TDG的高灵敏同位素稀释-负化学电离-气相色谱/质谱( ID-NCI-GC/MS)分析方法。研究了家兔皮肤芥子气(HD)染毒(0.02~0.15 LD50)后,尿液中TDG随时间变化的时效关系及其与HD染毒剂量间的量效关系。结果显示,本方法的检出限为0.1μg/L,定量限为0.3μg/L;家兔染毒后尿液中TDG含量迅速升

  11. Quantification and isotope ratio determination of uranium in particles of environmental samples using isotope dilution thermal ionization mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Choi, Eun-Ju [Chungnam National University, Daejeon (Korea, Republic of)

    2015-10-15

    Highly accurate and precise quantitative and qualitative analysis of nuclear materials in environmental samples plays essential roles in monitoring undeclared nuclear activities of corresponding facilities. The former focuses on the quantification of uranium (U) and plutonium (Pu) contained in a whole sample, while the latter enables us to acquire the isotopic ratios, which serve as the crucial basis to trace the nuclear histories of a facility. However, the quantity of nuclear materials in a single-particle has not been acquired from the particle analysis, but has been estimated by the size of the particles. This report is to describe the method developed to determine the quantity and the isotopic ratios of uranium in a micro-particle simultaneously. Complete dissolution of particle-spike mixture by repeated addition of nitric acid on a rhenium filament was performed to ensure the homogeneity of the mixture. Thermal ionization mass spectrometry (TIMS) was utilized to measure the U isotope ratios of the mixture with high accuracy. The isotopic ratios of the uranium in the particle sample were determined by mathematical deconvolution of U isotopic ratios of the mixture. Verification using particles of a certified reference material showed that the newly developed method can be used to quantify and to determine the isotopic ratios of U in a particle simultaneously. The development of a method for simultaneous determination of the quantity and the isotope ratios of uranium contained in particles by isotope dilution thermal ionization mass spectrometry (ID-TIMS) was described. For homogeneity of the mixture of particles and spike, repeated dissolution using nitric acid for five times was performed.

  12. Lysozyme refolding at high concentration by dilution and size-exclusion chromatography

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    This study of renaturation by dilution and size exclusion chromatography (SEC) addition of urea to improve yield as well as the initial and final protein concentrations showed that although urea decreased the rate of lysozyme refolding, it could suppress protein aggregation to sustain the pathway of correct refolding at high protein concentration; and that there existed an optimum urea concentration in renaturation buffer. Under the above conditions, lysozyme was successfully refolded from initial concentration of up to 40 mg/mL by dilution and 100 mg/mL by SEC, with the yield of the former being more than 40% and that of the latter being 34.8%. Especially, under the condition of 30 min interval time, i.e. τ>2(tR2-tR1), the efficiency was increased by 25% and the renaturation buffer could be recycled for SEC refolding in continuous operation of downstream process.

  13. Determination of homovanillic acid and vanillylmandelic acid in neuroblastoma screening by stable isotope dilution GC-MS.

    Science.gov (United States)

    Fauler, G; Leis, H J; Huber, E; Schellauf, C; Kerbl, R; Urban, C; Gleispach, H

    1997-05-01

    A method for the quantitative determination of homovanillic acid (HVA) and vanillylmandelic acid (VMA), two metabolites of catecholamines, is presented. The assay is based on gas chromatography/electron impact mass spectrometry. The preparation of 13C-labeled VMA from [13C6]vanillin is described. Together with purchased deuterated HVA the 13C-labeled VMA is used as an internal standard in stable isotope dilution GC/MS. The method involves elution from soaked filter-papers, determination of creatinine content, extraction of HVA and VMA from eluted and urinary samples and derivatization to the di-and tri(trimethylsilyl) derivatives, respectively. The detection limits were found to be 4.0 pg for HVA and 0.8 pg for VMA. The method was applied to the routine determination of urinary HVA and VMA in a range from 5 to 100 ng HVA and VMA per microgram creatinine. The lower limits of pathological concentrations are set at 35 ng micrograms-1 creatinine for HVA and to 20 ng micrograms-1 creatinine for VMA, which are in close correlation with the values from other methods, but with the main advantage of reducing the amount of questionable or elevated results from 6.7% (high-performance liquid chromatography (HPLC) alone) to 0.9% (HPLC and GC/MS).

  14. Determination of the urinary cortisol production rate using (1,2,3,4-13C)cortisol. Isotope dilution analyses at very small enrichments.

    Science.gov (United States)

    Chapman, T E; Kraan, G P; Drayer, N M; Nagel, G T; Wolthers, B G

    1987-02-01

    An isotope dilution mass spectrometric method to determine the urinary cortisol production rate (CPR) in babies and children is described. The method uses stable isotopically labelled (1,2,3,4-13C)cortisol. The tracer is intravenously administered to the patient and urine is collected for the following three days. Following extraction, enzymic hydrolysis, purification and isolation by high-performance liquid chromatography (HPLC) the urinary cortisol metabolites tetrahydrocortisone, tetrahydrocortisol, alpha- and beta-cortolone are separately oxidized the common product, 11-oxo-aetiocholanolone. The methyl oxime tert-butyldimethylsilyl ether derivative (MO TBDMS) was analysed by gas chromatography mass spectrometry. Quantification of the isotope enrichment was carried out by unlabelled, and at m/z 348 for labelled 11-oxo-aetiocholanolone. HPLC isolation of the metabolites together with the oxidation step allowed very small isotope enrichments, sometimes down to 0.1% (1:1000), to be reliably measured against a linear calibration graph containing 0 to 1% (13C4) enrichments. The standards for the calibration graph were synthesized from mixtures of labelled (13C4) cortisol and natural cortisol, and the calibration graph was prepared each time samples were measured. The long term instrumental precision of the isotope dilution analyses was 0.91% for a derivatized sample containing a (13C4) enrichment of 0.5% (measured on six different days over seven months). The coefficient of variation of the complete procedure for the four cortisol metabolites was between 1.17 and 2.14%. The clinical applicability of the method is demonstrated by presenting the results of a CPR determination in a patient.

  15. Solvent extraction, ion chromatography, and mass spectrometry of molybdenum isotopes.

    Science.gov (United States)

    Dauphas, N; Reisberg, L; Marty, B

    2001-06-01

    A procedure was developed that allows precise determination of molybdenum isotope abundances in natural samples. Purification of molybdenum was first achieved by solvent extraction using di(2-ethylhexyl) phosphate. Further separation of molybdenum from isobar nuclides was obtained by ion chromatography using AG1-X8 strongly basic anion exchanger. Finally, molybdenum isotopic composition was measured using a multiple collector inductively coupled plasma hexapole mass spectrometer. The abundances of molybdenum isotopes 92, 94, 95, 96, 97, 98, and 100 are 14.8428(510), 9.2498(157), 15.9303(133), 16.6787(37), 9.5534(83), 24.1346(394), and 9.6104(312) respectively, resulting in an atomic mass of 95.9304(45). After internal normalization for mass fractionation, no variation of the molybdenum isotopic composition is observed among terrestrial samples within a relative precision on the order of 0.00001-0.0001. This demonstrates the reliability of the method, which can be applied to searching for possible isotopic anomalies and mass fractionation.

  16. The effective surface energy of heterogeneous solids measured by inverse gas chromatography at infinite dilution.

    Science.gov (United States)

    Sun, Chenhang; Berg, John C

    2003-04-15

    Inverse gas chromatography (IGC) at infinite dilution has been widely used to access the nonspecific surface free energy of solid materials. Since most practical surfaces are heterogeneous, the effective surface energy given by IGC at infinite dilution is somehow averaged over the whole sample surface, but the rule of averaging has thus far not been established. To address this problem, infinite dilution IGC analysis was carried out on mixtures of known heterogeneity. These materials are obtained by mixing two types of solid particles with significantly different surface energies as characterized individually with IGC, and results are obtained for binary combinations in varying proportions. It is found that when all surface components have the same accessibility by probe molecules, the effective surface energy of such a heterogeneous surface is related to the surface energy distribution by a square root linear relationship, square root sigma(eff)(LW)= summation operator (i)phi(i) square root sigma(i)(LW), where sigma(i)(LW) refers to the nonspecific (Lifshitz-van der Waals) surface energy of patches i, and phi(i) to their area fraction.

  17. Determination of 18 pesticide residues in red wine by ultra high performance liquid chromatography-high resolution mass spectrometry with isotope dilution technique%超高效液相色谱-同位素稀释高分辨质谱法测定红葡萄酒中的18种农药残留

    Institute of Scientific and Technical Information of China (English)

    陈达炜; 吕冰; 丁颢; 邹建宏; 杨欣; 赵云峰; 苗虹

    2014-01-01

    A method for the simultaneous determination of 18 pesticide residues in red wine was developed using ultra high performance liquid chromatography-high resolution mass spec-trometry( UPLC-HRMS)with isotope dilution technique. The red wine samples were extracted with acetonitrile,and the extracts were cleaned up with dispersive solid phase extraction( d-SPE)using the mixture of N-propyl ethylene diamine( PSA)and C18 powder as sorbent. The extracted components were separated on a BEH C 18 column by gradient elution. The qualitative and quantitative analyses were operated under full scan/data dependent MS/MS( ddms 2 )and targeted selective ion monitoring( tSIM)by high resolution mass spectrometry,respectively. Carbendazim-D4,chlorpyrifos-D10,imidacloprid-D4,methoxyfenozide-D9,pyrimethanil-D5 and tebuconazole-D6 were used as the internal standards to reduce the matrix effects. The response of each pesticide showed a good linearity in the range of 0. 5-50 μg/kg with the correlation coefficient more than 0. 999. The limits of detection and quantification for the 18 pesticides in the spiked blank red wine were 0. 5 μg/kg and 1. 0 μg/kg,respectively. The recovery results with spiked blank red wine samples at the levels of 1 to 40 μg/kg were satisfactory with average recoveries of 85. 4%-117. 9% and the RSDs of 0. 5%-6. 1%. The method was applied for the determination of the red wine real samples from the market. Carbendazim, imidacloprid, pyrimethanil,tebuconazole and triadimenol were detected in the samples. The results show that the method is suitable for the rapid screening and quantitative analysis of pesticide residues in red wine.%建立了采用超高效液相色谱-同位素稀释高分辨质谱法同时快速测定红葡萄酒中18种农药残留的方法。样品采用乙腈提取,以 N-丙基乙二胺(PSA)和 C18作为吸附剂的分散固相萃取法(d-SPE)进行净化,以 BEH C18色谱柱进行色谱分离,分别通过高分辨质谱的全

  18. 同位素稀释-固相萃取-超快速液相色谱/串联质谱联用法测定鳝鱼中9种雌激素%Simultaneous determination of nine estrogens in eel by ultrafast liquid chromatography-tandem mass spectrometry with isotope dilution technique and solid-phase extraction

    Institute of Scientific and Technical Information of China (English)

    陈晓红; 姚珊珊; 李小平; 赵永纲; 金米聪

    2012-01-01

    Objective Developing a rapid and sensitive analytical method based on ultrafast liquid chromatography-tandem mass spectrometry ( UFLC-MS/MS) with solid-phase extraction ( SPE) for the simultaneous determination of nine estrogens (dienestrol, diethylstilbestrol, estrone, hexestrol, 17-alpha-estradiol, 17-beta-estradiol, estriol, 17α-ethinylestradiol and estradiol valerate) in eel. Methods After the sample was extracted by acetonitrile and cleaned by Waters Oasis" HLB solid-phase extraction cartridge, the UFLC separation was performed on a Shim-pack XR-ODS II column ( 100mm × 2. 0mm, 2. 2μm) with a linear gradient elution program of methanol solution containing 0.04% ammonia (v/v) and 0.04% ammonia aqueous solution ( v/v) as the mobile phase. Electrospray ionization was applied and operated in the negative multiple reaction monitoring (MRM) mode. The quantitation was used by isotope internal standard dilution technique. Results The results showed that the limits of quantitation (LOQs, S/N(10) were in the range of 0. 07-0. 4μg/kg, the calibration curves were in good linearities for the nine analytes in the range of 0. 5-50. 0μg/L with the correlative coefficients ( r2 ) more than 0. 998 , the recoveries were between 81. 0% and 110. 0% with the relative standard deviations (RSDs) of 1.92%-8. 24%. Additional, the mass spectra characterization of the nine estrogens was discussed and the fragmentation pathways were speculated. Conclusion The developed method is rapid, sensitive, specific and reproducible, and adapts not only to the simultaneous determination of the nine trace estrogens including the epimer of 17-alpha-estradiol and 17-beta-estradiol but also to the identified detection in other fish tissues.%目的 建立一种快速、灵敏的鳝鱼中己二烯雌酚、己烯雌酚、雌酮、己烷雌酚、17α-雌二醇、17β-雌二醇、雌三醇、17α-炔雌醇和戊酸雌二醇等9种雌激素残留的固相萃取超快速液相色谱-串联质谱(UFLC-MS/MS

  19. Isotope dilution ICP-MS with laser-assisted sample introduction for direct determination of sulfur in petroleum products.

    Science.gov (United States)

    Boulyga, Sergei F; Heilmann, Jens; Heumann, Klaus G

    2005-08-01

    Inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with direct laser-assisted introduction of isotope-diluted samples into the plasma, using a laser ablation system with high ablation rates, was developed for accurate sulfur determinations in different petroleum products such as 'sulfur-free' premium gasoline, diesel fuel, and heating oil. Two certified gas oil reference materials were analyzed for method validation. Two different 34S-enriched spike compounds, namely, elementary sulfur dissolved in xylene and dibenzothiophene in hexane, were synthesized and tested for their usefulness in this isotope dilution technique. The isotope-diluted sample was adsorbed on a filter-paper-like material, which was fixed in a special holder for irradiation by the laser beam. Under these conditions no time-dependent spike/analyte fractionation was only observed for the dibenzothiophene spike during the laser ablation process, which means that the measured 34S/32S isotope ratio of the isotope-diluted sample remained constant-a necessary precondition for accurate results with the isotope dilution technique. A comparison of LA-ICP-IDMS results with the certified values of the gas oil reference materials and with results obtained from ICP-IDMS analyses with wet sample digestion demonstrated the accuracy of the new LA-ICP-IDMS method in the concentration range of 9.2 microg g(-1) ('sulfur-free' premium gasoline) to 10.4 mg g(-1) (gas oil reference material BCR 107). The detection limit for sulfur by LA-ICP-IDMS is 0.04 microg g(-1) and the analysis time is only about 10 min, which therefore also qualifies this method for accurate determinations of low sulfur contents in petroleum products on a routine level.

  20. Isotope dilution ICP-MS with laser-assisted sample introduction for direct determination of sulfur in petroleum products

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, Sergei F.; Heilmann, Jens; Heumann, Klaus G. [Johannes Gutenberg-University Mainz (Germany). Institute of Inorganic Chemistry and Analytical Chemistry

    2005-08-01

    Inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with direct laser-assisted introduction of isotope-diluted samples into the plasma, using a laser ablation system with high ablation rates, was developed for accurate sulfur determinations in different petroleum products such as 'sulfur-free' premium gasoline, diesel fuel, and heating oil. Two certified gas oil reference materials were analyzed for method validation. Two different {sup 34}S-enriched spike compounds, namely, elementary sulfur dissolved in xylene and dibenzothiophene in hexane, were synthesized and tested for their usefulness in this isotope dilution technique. The isotope-diluted sample was adsorbed on a filter-paper-like material, which was fixed in a special holder for irradiation by the laser beam. Under these conditions no time-dependent spike/analyte fractionation was only observed for the dibenzothiophene spike during the laser ablation process, which means that the measured {sup 34}S/{sup 32}S isotope ratio of the isotope-diluted sample remained constant - a necessary precondition for accurate results with the isotope dilution technique. A comparison of LA-ICP-IDMS results with the certified values of the gas oil reference materials and with results obtained from ICP-IDMS analyses with wet sample digestion demonstrated the accuracy of the new LA-ICP-IDMS method in the concentration range of 9.2 {mu}g g{sup -1} ('sulfur-free' premium gasoline) to 10.4 mg g{sup -1} (gas oil reference material BCR 107). The detection limit for sulfur by LA-ICP-IDMS is 0.04 {mu}g g{sup -1} and the analysis time is only about 10 min, which therefore also qualifies this method for accurate determinations of low sulfur contents in petroleum products on a routine level. (orig.)

  1. Stable carbon isotopic composition of gasolines determined by isotope ratio monitoring gas chromatography mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Smallwood, B.J.; Philp, R.P.; Allen, J.D. [University of Oklahoma, Norman, OK (United States). School of Geology and Geophysics

    2002-07-01

    A large number of underground gasoline storage facilities in the United States continuously leak gasoline into the subsurface, which makes gasoline a major groundwater contaminant. Gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS) are used currently to characterize contaminated groundwater and soils. Correlations of contaminants with suspected source(s) are extremely difficult by these techniques because many gasolines have similar hydrocarbon distributions. The present study applied the technique of isotope ratio monitoring gas chromatography-mass spectrometry (irmGC-MS) to 19 gasoline samples from different areas of the USA. This allows a much better correlation of gasoline contaminants to source. Data obtained indicate a wide range of {sup {delta}}{sup 13}C values for 16 ubiquitous compounds in the gasolines. The majority of samples could be distinguished from each other on the basis of {sup {delta}}{sup 13}C hydrocarbon composition. The oxygenated additive methyl tertiary butyl ether (MTBE) was present in ten of the gasolines analyzed, and had a relatively narrow range of {sup {delta}}{sup 13}C values (-30.4 to -28.3 per mille). Preliminary investigations were also made to determine the extent of carbon isotopic fractionation after simple water washing and evaporation experiments. Results indicate that the majority of compounds did not undergo significant carbon isotopic fractionation as a result of these processes. (author)

  2. Determination of ultra-trace levels of priority PBDEs in water samples by isotope dilution GC(ECNI)MS using {sup 81}Br-labelled standards

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Gago, Adriana; Marchante-Gayon, Juan Manuel; Garcia Alonso, J.I. [University of Oviedo, Department of Physical and Analytical Chemistry, Faculty of Chemistry, Oviedo (Spain); Brandsma, Sicco H.; Leonards, Pim E.G.; Boer, Jacob de [VU University, Institute for Environmental Studies, Amsterdam (Netherlands)

    2011-11-15

    A gas chromatography electron capture negative ionization mass spectrometry (GC(ECNI)MS) procedure for the determination of priority polybrominated diphenyl ethers (PBDEs; congeners 28, 47, 99, 100, 153 and 154) in water samples at regulatory EU levels has been developed. The method is based on the use of {sup 81}Br-labelled PBDEs for isotope dilution analysis and the measurement of {sup 79}Br/{sup 81}Br isotope ratios in gas chromatography peaks with the electron capture negative ionization technique. The suitability of this ion source for the precise and accurate measurement of bromine isotope ratios has been demonstrated. The general ECNI-IDMS procedure was evaluated by the analysis of NIST SRM 1947 (Lake Michigan fish tissue) with satisfactory results. For the analysis of water samples, 500 mL of the samples were spiked with the labelled PBDEs and extracted with 10 mL isooctane for 30 min. The extract was evaporated down to ca. 100 {mu}L and injected in the GC(ECNI)MS. Detection limits ranged from 0.014 {sup -1} to 0.089 pg mL{sup -1} depending on the congener. Recoveries from real water samples, spiked at a level of 0.5 pg mL{sup -1}, ranged from 77% to 102%. (orig.)

  3. Screening of dimethoate in food by isotope dilution and electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Mazzotti, Fabio; Di Donna, Leonardo; Macchione, Barbara; Maiuolo, Loredana; Perri, Enzo; Sindona, Giovanni

    2009-05-01

    Crop control is an important issue in both developed and developing countries. An environmentally friendly approach is represented by the so-called Integrated Pest Management (IPM), whereby synthetic pesticides are only applied as a last resort, under the strict control of suitable experts. European and US regulatory authorities, such as the US EPA, are constantly assessing the risks of exposure to the organophosphate (OP) class of pesticides and, among these, specifically dimethoate. The use of dimethoate is still allowed in many crops, including olives, which once was based in the Mediterranean area but now is expanding rapidly throughout the world. An important aspect of IPM protocols is represented by the availability of reliable and sensitive methods to detect pesticides residues. This paper describes an isotope dilution dimethoate assay based on the application of electrospray ionization tandem mass spectrometry (ESI-MS/MS) by means of a deuterium-labeled internal standard.

  4. Quantification of four artificial sweeteners in Finnish surface waters with isotope-dilution mass spectrometry.

    Science.gov (United States)

    Perkola, Noora; Sainio, Pirjo

    2014-01-01

    The artificial sweeteners sucralose (SCL), acesulfame (ACS), saccharin (SAC), and cyclamate (CYC) have been detected in environmental waters in Europe and North America. Higher environmental levels are expected in view of the increasing consumption of these food additives. In this study, an isotope-dilution mass spectrometry (IDMS) LC-MS/MS method was developed and validated for quantifying the four artificial sweeteners in boreal lakes (n = 3) and rivers (n = 12). The highest concentrations of ACS, SAC, CYC and SCL were 9,600, 490, 210 and 1000 ng/L, respectively. ACS and SAC were detected in all studied samples, and CYC and SCL in 98% and 56% of the samples. Seasonal trends of ACS and SAC were observed in some rivers. ACS and SCL concentrations in rivers correlated linearly with population equivalents of the wastewater treatment plants in the catchment areas, whereas SAC and CYC concentrations depend more on the source.

  5. Assay of tyrosol and hydroxytyrosol in olive oil by tandem mass spectrometry and isotope dilution method.

    Science.gov (United States)

    Mazzotti, Fabio; Benabdelkamel, Hicham; Di Donna, Leonardo; Maiuolo, Loredana; Napoli, Anna; Sindona, Giovanni

    2012-12-01

    Hydroxytyrosol and tyrosol, the strong antioxidant present in large amount in virgin olive oil have been assayed by LC-MS/MS under MRM condition and isotope dilution method, using d(2)-labelled internal standards obtained by simple synthetic procedures. The assay has been performed under MRM condition monitoring two transitions for each analyte to improve the specificity. This paper deals with a modern approach for assaying the content of this polyphenols in virgin olive oil down to a limit of a few hundreds of parts per billion. Tyrosol and hydroxytyrosol ranged from 10 to 47ppm and from 5 to 25ppm in commercial olive oil, respectively. The accuracy (98-107%) and analytical parameters values confirm the reliability of the proposed approach. The method can be extended to any natural matrices, including mill wastes, after a simple step of sample preparation.

  6. Determination of tenuazonic acid in human urine by means of a stable isotope dilution assay.

    Science.gov (United States)

    Asam, Stefan; Habler, Katharina; Rychlik, Michael

    2013-05-01

    The content of tenuazonic acid in human urine was determined by a stable isotope dilution assay (SIDA) that was recently developed for the analysis of food commodities and extensively re-validated for urine matrix in this study. Linearity of the response curve was proven between molar ratios n(labeled standard)/n(analyte) of 0.02-100. The limits of detection and determination were 0.2 and 0.6 μg/L, respectively. The mean recovery of the stable isotope dilution assay was 102 ± 3 % in the range between 1.0 and 100 μg/L. Interassay precision was 6.7 % (relative standard deviation of three triplicate analyses of a human urine sample during 3 weeks). The method was applied to two studies dealing with urinary excretion of tenuazonic acid: In the first study, tenuazonic acid was quantified in the 24-h urine of six volunteers from Germany (three female, three male) in a concentration range of 1.3-17.3 μg/L or 2.3-10.3 ng/mg(-1) creatinine, respectively. In the second study, two volunteers (one female, one male) ingested 30 μg tenuazonic acid by consumption of naturally contaminated whole meal sorghum infant cereals and tomato juice, respectively. The urinary excretion of the ingested tenuazonic acid was 54-81 % after 6 h, depending on matrix and volunteer. After 24 h, 87-93 % of the ingested amount of tenuazonic acid was excreted, but the fate of the remaining about 10 % is open. Thus, it is not possible to exclude potential health hazards for the consumer, completely.

  7. Isotope dilution analysis of Ca and Zr in apatite and zircon (U-Th)/He chronometry

    Science.gov (United States)

    Guenthner, William R.; Reiners, Peter W.; Chowdhury, Uttam

    2016-05-01

    Because radiation damage influences He diffusivity, correlations between (U-Th)/He ages and effective uranium (eU, eU = U + 0.235 × Th) concentrations of single apatite and zircon grains are important for understanding thermal histories. Here we describe a method for quantifying eU concentrations in apatite and zircon grains using isotope dilution ICP-MS measurements of Zr and Ca and stoichiometry of zircon (ZrSiO4) and apatite (Ca5(PO4)3F) to obtain grain masses. Combined with independent U and Th measurements, these yield eU concentrations not based on the traditional morphologic measurements and assumptions. Additional benefits of this method include correct identification of an apatite or zircon and volume estimates for crystal shards. In some cases, this method gives eU concentrations consistent with those calculated with the morphologic approach, but often significant differences are observed between concentrations calculated from the two methods. Differences in eU concentrations for our apatite grains are greater and less than morphology estimates, and the majority are between 0.7 and 31%. With the exception of two grains, all of our zircon grains have differences between 3 and 34% less than morphology estimates. These differences could result from incorrect grain width measurements, mischaracterized grain shape, or incorrect volume calculations of the pure mineral phase due to inclusions. These morphologic errors—combined with evidence for the accuracy of our isotope dilution method from analyses of reference materials—suggest that eU concentrations calculated from morphology may often be significantly inaccurate. Finally, we demonstrate that differences between the two measurements of eU cause age-eU correlation variations for representative thermal histories.

  8. The Influence of Seed-borne N in 15N Isotope Dilution Studies with Legumes The Influence of Seed-borne N in 15N Isotope Dilution Studies with Legumes

    DEFF Research Database (Denmark)

    Jensen, Erik Steen; Andersen, A. J.; Thomsen, J. D.

    1985-01-01

    The distriution of seed-borne N in shoot and root of pea and field bean was studied using three methods: 1) determination of the N content in shoot and root of plants grown in sand culture without other N sources. 2) 15N isotope dilution in plants grown in Rhizobium-free medium supplied with 15N...

  9. Glass transition of adsorbed stereoregular PPMA by inverse gas chromatography at infinite dilution

    Science.gov (United States)

    Hamieh, T.; Rezzaki, M.; Grohens, Y.; Schultz, J.

    1998-10-01

    In this paper, we used inverse gas chromatography (IGC) at infinite dilution that proved to be a powerful technique to determine glass transition and other transitions of PMMA adsorbed on α-alumina. We highlighted the glass transition temperature of the system PMMA/α-Al2O3 with defined polymer tacticity at various covered surface fractions. Thus, the Tg of the adsorbed isotactic PMMA increases strongly as compared to the bulk value. The study of the physical chemical properties of PMMA/α-alumina revealed an important difference in the acidic and basic behaviour, in Lewis terms, of aluminium oxide covered by various concentrations of PMMA. It appears that there is a stabilisation of the physical chemical properties of PMMA/α-Al2O3 for a surface coverage above 50%. This study also highlighted an important effect of the tacticity of the polymer on the acid-base character of the system PMMA/Al2O3. Dans cet article, nous montrons que la chromatographie gazeuse inverse (CGI) à dilution infinie se révèle être une technique très intéressante pour la détermination de la transition vitreuse de polymères stéréoréguliers adsorbés sur des substrats solides tels que l'alumine. Nous avons mis en évidence des transitions attribuées aux phénomènes de relaxation béta, transition vitreuse et autres transitions des systèmes PMMA/Al2O3 de tacticité définie à différents taux de recouvrement. Ainsi, la Tg du PMMA isotactique adsorbé augmente de façon significative par rapport a celle du polymère massique. L'étude des propriétés physico-chimiques du système PMMA/Al2O3, révèle une différence importante dans le comportement acido-basique, au sens de Lewis, de l'alumine pour de taux de recouvrement en PMMA variables. Il apparaît qu'il y a stabilisation des propriétés physico-chimiques de PMMA/Al2O3 pour un taux de recouvrement en PMMA supérieur à 50 %. Cette étude a montré également une influence importante de la tacticité du polymère sur le

  10. Vitamin A equivalency and apparent absorption of ß-carotene in ileostomy subjects using a dual-isotope dilution technique

    NARCIS (Netherlands)

    Bouwman, C.A.; Naber, T.H.J.; Breemen, van R.B.; Zhu, D.; Dicke, H.; Siebelink, E.; Hulshof, P.J.M.; Russel, F.G.M.; Schaafsma, G.; West, C.E.

    2010-01-01

    The objective was to quantify the vitamin A equivalency of ß-carotene in two diets using a dual-isotope dilution technique and the apparent ß-carotene absorption as measured by the oral–faecal balance technique. Seventeen healthy adults with an ileostomy completed the 4-week diet-controlled, cross-o

  11. Vitamin A equivalency and apparent absorption of beta-carotene in ileostomy subjects using a dual-isotope dilution technique.

    NARCIS (Netherlands)

    Loo-Bouwman, C.A. Van; Naber, T.H.; Breemen, R.B. van; Zhu, D.; Dicke, H.; Siebelink, E.; Hulshof, P.J.; Russel, F.G.M.; Schaafsma, G.; West, C.E.

    2010-01-01

    The objective was to quantify the vitamin A equivalency of beta-carotene in two diets using a dual-isotope dilution technique and the apparent beta-carotene absorption as measured by the oral-faecal balance technique. Seventeen healthy adults with an ileostomy completed the 4-week diet-controlled, c

  12. An isotope dilution model for partitioning phenylalanine and tyrosine uptake by the mammary gland of lactating dairy cows

    NARCIS (Netherlands)

    Crompton, L.A.; France, J.; Reynolds, C.K.; Mills, J.A.N.; Hanigan, M.D.; Ellis, J.L.; Bannink, A.; Bequette, B.J.; Dijkstra, J.

    2014-01-01

    An isotope dilution model for partitioning phenylalanine and tyrosine uptake by the mammary gland of the lactating dairy cow is constructed and solved in the steady state. The model contains four intracellular and four extracellular pools and conservation of mass principles is applied to generate th

  13. Profiles of Steroid Hormones in Canine X-Linked Muscular Dystrophy via Stable Isotope Dilution LC-MS/MS.

    Directory of Open Access Journals (Sweden)

    Helio A Martins-Júnior

    Full Text Available Golden retriever muscular dystrophy (GRMD provides the best animal model for characterizing the disease progress of the human disorder, Duchenne muscular dystrophy (DMD. The purpose of this study was to determine steroid hormone concentration profiles in healthy golden retriever dogs (control group - CtGR versus GRMD-gene carrier (CaGR and affected female dogs (AfCR. Therefore, a sensitive and specific analytical method was developed and validated to determine the estradiol, progesterone, cortisol, and testosterone levels in the canine serum by isotope dilution liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS. To more accurately understand the dynamic nature of the serum steroid profile, the fluctuating levels of these four steroid hormones over the estrous cycle were compared across the three experimental groups using a multivariate statistical analysis. The concentration profiles of estradiol, cortisol, progesterone, and testosterone revealed a characteristic pattern for each studied group at each specific estrous phase. Additionally, several important changes in the serum concentrations of cortisol and estradiol in the CaGR and AfCR groups seem to be correlated with the status and progression of the muscular dystrophy. A comprehensive and quantitative monitoring of steroid profiles throughout the estrous cycle of normal and GRMD dogs were achieved. Significant differences in these profiles were observed between GRMD and healthy animals, most notably for estradiol. These findings contribute to a better understanding of both dog reproduction and the muscular dystrophy pathology. Our data open new venues for hormonal behavior studies in dystrophinopathies and that may affect the quality of life of DMD patients.

  14. Biosynthesis of 15N-labeled cylindrospermopsin and its application as internal standard in stable isotope dilution analysis.

    Science.gov (United States)

    Kittler, Katrin; Hoffmann, Holger; Lindemann, Franziska; Koch, Matthias; Rohn, Sascha; Maul, Ronald

    2014-09-01

    Cylindrospermopsin (CYN) is a cyanobacterial toxin associated with human and animal poisonings. Due to its toxicity in combination with its widespread occurrence, the development of reliable methods for selective, sensitive detection and accurate quantification is mandatory. Liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis using stable isotope dilution analysis (SIDA) represents an ideal tool for this purpose. U-[(15)N5]-CYN was synthesized by culturing Aphanizomenon flos-aquae in Na(15)NO3-containing cyanobacteria growth medium followed by a cleanup using graphitized carbon black columns and mass spectrometric characterization. Subsequently, a SIDA-LC-MS/MS method for the quantification of CYN in freshwater and Brassica matrices was developed showing satisfactory performance data. The recovery ranged between 98 and 103 %; the limit of quantification was 15 ng/L in freshwater and 50 μg/kg dry weight in Brassica samples. The novel SIDA was applied for CYN determination in real freshwater samples as well as in kale and in vegetable mustard exposed to toxin-containing irrigation water. Two of the freshwater samples taken from German lakes were found to be CYN-contaminated above limit of quantification (17.9 and 60.8 ng/L). CYN is systemically available to the examined vegetable species after exposure of the rootstock leading to CYN mass fractions in kale and vegetable mustard leaves of 15.0 μg/kg fresh weight and 23.9 μg/kg fresh weight, respectively. CYN measurements in both matrices are exemplary for the versatile applicability of the developed method in environmental analysis.

  15. Measurement of mercury species in human blood using triple spike isotope dilution with SPME-GC-ICP-DRC-MS.

    Science.gov (United States)

    Sommer, Yuliya L; Verdon, Carl P; Fresquez, Mark R; Ward, Cynthia D; Wood, Elliott B; Pan, Yi; Caldwell, Kathleen L; Jones, Robert L

    2014-08-01

    The measurement of different mercury compounds in human blood can provide valuable information about the type of mercury exposure. To this end, our laboratory developed a biomonitoring method for the quantification of inorganic (iHg), methyl (MeHg), and ethyl (EtHg) mercury in whole blood using a triple-spike isotope dilution (TSID) quantification method employing capillary gas chromatography (GC) and inductively coupled dynamic reaction cell mass spectrometry (ICP-DRC-MS). We used a robotic CombiPAL(®) sample handling station featuring twin fiber-based solid-phase microextraction (SPME) injector heads. The use of two SPME fibers significantly reduces sample analysis cycle times making this method very suitable for high sample throughput, which is a requirement for large public health biomonitoring studies. Our sample preparation procedure involved solubilization of blood samples with tetramethylammonium hydroxide (TMAH) followed by the derivatization with sodium tetra(n-propyl)borate (NaBPr(4)) to promote volatility of mercury species. We thoroughly investigated mercury species stability in the blood matrix during the course of sample treatment and analysis. The method accuracy for quantifying iHg, MeHg, and EtHg was validated using NIST standard reference materials (SRM 955c level 3) and the Centre de Toxicologie du Québec (CTQ) proficiency testing (PT) samples. The limit of detection (LOD) for iHg, MeHg, and EtHg in human blood was determined to be 0.27, 0.12, and 0.16 μg/L, respectively.

  16. Chemically selective polymer substrate based direct isotope dilution alpha spectrometry of Pu.

    Science.gov (United States)

    Paul, Sumana; Pandey, Ashok K; Shah, R V; Aggarwal, S K

    2015-06-01

    Quantification of actinides in the complex environmental, biological, process and waste streams samples requires multiple steps like selective preconcentration and matrix elimination, solid source preparations generally by evaporation or electrodeposition, and finally alpha spectrometry. To minimize the sample manipulation steps, a membrane based isotope dilution alpha spectrometry method was developed for the determination of plutonium concentrations in the complex aqueous solutions. The advantages of this method are that it is Pu(IV) selective at 3M HNO3, high preconcentration factor can be achieved, and obviates the need of solid source preparation. For this, a thin phosphate-sulfate bifunctional polymer layer was anchored on the surface of microporous poly(ethersulfone) membrane by UV induced surface grafting. The thickness of the bifunctional layer on one surface of the poly(ethersulfone) membrane was optimized. The thickness, physical and chemical structures of the bifunctional layer were studied by secondary ionization mass spectrometry (SIMS), scanning electron microscopy (SEM) and SEM-EDS (energy-dispersive spectroscopy). The optimized membrane was used for preconcentration of Pu(IV) from aqueous solutions having 3-4M HNO3, followed by direct quantification of the preconcentrated Pu(IV) by isotope dilution alpha spectrometry using (238)Pu spike. The chemical recovery efficiency of Pu(IV) was found to be 86±3% below Pu(IV) loading capacity (1.08 μg in 2×1 cm(2)) of the membrane sample. The experiments with single representative actinides indicated that Am(III) did not sorb to significant extent (7%) but U(VI) sorbed with 78±3% efficiency from the solutions having 3M HNO3 concentration. However, Pu(IV) chemical recovery in the membrane remained unaffected from the solution containing 1:1000 wt. proportion of Pu(IV) to U(VI). Pu concentrations in the (U, Pu)C samples and in the irradiated fuel dissolver solutions were determined. The results thus obtained

  17. Use of isotope-labeled aflatoxins for LC-MS/MS stable isotope dilution analysis of foods.

    Science.gov (United States)

    Cervino, Christian; Asam, Stefan; Knopp, Dietmar; Rychlik, Michael; Niessner, Reinhard

    2008-03-26

    Aflatoxins are a group of very carcinogenic mycotoxins that can be found on a wide range of food commodities including nuts, cereals, and spices. In this study, the first LC-MS/MS stable isotope dilution assay (SIDA) for the determination of aflatoxins in foods was developed. The development of this method was enabled by easily accessible isotope-labeled (deuterated) aflatoxins B2 and G2, which were synthesized by catalytic deuteration of aflatoxin B1 and G1, purified, and well-characterized by NMR and MS. All four aflatoxins of interest (B1, B2, G1, and G2) were quantified in food samples by using these two labeled internal standards. The response factors (RF) of the linear calibrations were revealed to be matrix independent for labeled aflatoxin B2/aflatoxin B2 and labeled aflatoxin G2/aflatoxin G2. For labeled aflatoxin B 2/aflatoxin B 1 and labeled aflatoxin B2/aflatoxin G1 matrix-matched calibration was performed for the model matrices almonds and wheat flour, showing significant differences of the RFs. Limits of detection (LOD) were determined by applying a statistical approach in the presence of the two model matrices, yielding 0.31 microg/kg (aflatoxin B1), 0.09 microg/kg (aflatoxin B2), 0.38 microg/kg (aflatoxin G1), and 0.32 microg/kg (aflatoxin G2) for almonds (similar LODs were obtained for wheat flour). Recovery rates were between 90 and 105% for all analytes. Coefficients of variation (CV) of 12% (aflatoxin B1), 3.6% (aflatoxin B2), 14% (aflatoxin G1), and 4.8% (aflatoxin G2) were obtained from interassay studies. For further validation, a NIST standard reference food sample was analyzed for aflatoxins B1 and B2. The method was successfully applied to determine trace levels of aflatoxins in diverse food matrices such as peanuts, nuts, grains, and spices. Aflatoxin contents in these samples ranged from about 0.5 to 6 microg/kg.

  18. Determination of benzene in different food matrices by distillation and isotope dilution HS-GC/MS

    Energy Technology Data Exchange (ETDEWEB)

    Medeiros Vinci, Raquel [Department of Food Safety and Food Quality, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, B-9000 Ghent (Belgium); Canfyn, Michael [Food, Medicines and Consumer Safety, Scientific Institute of Public Health, Rue Juliette Wytsmanstraat 14, 1050 Brussels (Belgium); De Meulenaer, Bruno [Department of Food Safety and Food Quality, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, B-9000 Ghent (Belgium); Schaetzen, Thibault de; Van Overmeire, Ilse; De Beer, Jacques [Food, Medicines and Consumer Safety, Scientific Institute of Public Health, Rue Juliette Wytsmanstraat 14, 1050 Brussels (Belgium); Van Loco, Joris, E-mail: Joris.VanLoco@iph.fgov.BE [Food, Medicines and Consumer Safety, Scientific Institute of Public Health, Rue Juliette Wytsmanstraat 14, 1050 Brussels (Belgium)

    2010-07-05

    Benzene is classified by the IARC as carcinogenic to humans. Several sources may contribute for the occurrence of benzene in foods, such as, environmental contamination and the reaction of benzoate salts with ascorbic acid (naturally present or added as food additives). Matrix effect on benzene recovery (e.g. in fatty foods) and artefactual benzene formation from benzoate during analysis in the presence of ascorbate are some of the challenges presented when determining benzene in a wide range of foodstuffs. Design of experiment (DOE) was used to determine the most important variables in benzene recovery from headspace GC/MS. Based on the results of the DOE, a versatile method for the extraction of benzene from all kind of food commodities was developed. The method which consisted of distillation and isotope dilution HS-GC/MS was in-house validated. Artefactual benzene was prevented by addition of a borate buffer solution (pH 11) under distillation conditions. The method presented in this study allows the use of a matrix-independent calibration with detection limits below the legal limit established by the European Council for benzene in drinking water (1 {mu}g L{sup -1}).

  19. Determination of benzene in different food matrices by distillation and isotope dilution HS-GC/MS.

    Science.gov (United States)

    Vinci, Raquel Medeiros; Canfyn, Michael; De Meulenaer, Bruno; de Schaetzen, Thibault; Van Overmeire, Ilse; De Beer, Jacques; Van Loco, Joris

    2010-07-01

    Benzene is classified by the IARC as carcinogenic to humans. Several sources may contribute for the occurrence of benzene in foods, such as, environmental contamination and the reaction of benzoate salts with ascorbic acid (naturally present or added as food additives). Matrix effect on benzene recovery (e.g. in fatty foods) and artefactual benzene formation from benzoate during analysis in the presence of ascorbate are some of the challenges presented when determining benzene in a wide range of foodstuffs. Design of experiment (DOE) was used to determine the most important variables in benzene recovery from headspace GC/MS. Based on the results of the DOE, a versatile method for the extraction of benzene from all kind of food commodities was developed. The method which consisted of distillation and isotope dilution HS-GC/MS was in-house validated. Artefactual benzene was prevented by addition of a borate buffer solution (pH 11) under distillation conditions. The method presented in this study allows the use of a matrix-independent calibration with detection limits below the legal limit established by the European Council for benzene in drinking water (1 microg L(-1)).

  20. Determination of iodine in oyster tissue by isotope dilution laser resonance ionization mass spectrometry.

    Science.gov (United States)

    Fassett, J D; Murphy, T J

    1990-02-15

    The technique of laser resonance ionization mass spectrometry has been combined with isotope dilution analysis to determine iodine in oyster tissue. The long-lived radioisotope, 129I, was used to spike the samples. Samples were equilibrated with the 129I, wet ashed under controlled conditions, and iodine separated by coprecipitation with silver chloride. The analyte was dried as silver ammonium iodide upon a tantalum filament from which iodine was thermally desorbed in the resonance ionization mass spectrometry instrument. A single-color, two-photon resonant plus one-photon ionization scheme was used to form positive iodine ions. Long-lived iodine signals were achieved from 100 ng of iodine. The precision of 127I/129I measurement has been evaluated by replicate determinations of the spike, the spike calibration samples, and the oyster tissue samples and was 1.0%. Measurement precision among samples was 1.9% for the spike calibration and 1.4% for the oyster tissue. The concentration of iodine determined in SRM 1566a, Oyster Tissue, was 4.44 micrograms/g with an estimate of the overall uncertainty for the analysis of +/- 0.12 microgram/g.

  1. Multi-mycotoxin stable isotope dilution LC-MS/MS method for Fusarium toxins in beer.

    Science.gov (United States)

    Habler, Katharina; Gotthardt, Marina; Schüler, Jan; Rychlik, Michael

    2017-03-01

    A stable isotope dilution LC-MS/MS multi-mycotoxin method was developed for 12 different Fusarium toxins including modified mycotoxins in beer (deoxynivalenol-3-glucoside, deoxynivalenol, 3-acetyldeoxynivalenol, 15-acetyl-deoxynivalenol, HT2-toxin, T2-toxin, enniatin B, B1, A1, A, beauvericin and zearalenone). As sample preparation and purification of beer a combined solid phase extraction for trichothecenes, enniatins, beauvericin and zearalenone was firstly developed. The validation of the new method gave satisfying results: intra-day and inter-day precision and recoveries were 1-5%, 2-8% and 72-117%, respectively. In total, 61 different organic and conventional beer samples from Germany and all over the world were analyzed by using the newly developed multi-mycotoxin method. In summary, deoxynivalenol, deoxynivalenol-3-glucoside, 3-acetyldeoxynivaleneol and enniatin B were quantified in rather low contents in the investigated beer samples. None of the other monitored Fusarium toxins like 15-acetyldeoxynivalenol, HT2- and T2-toxin, zearalenone, enniatin B1, A1, A or beauvericin were detectable.

  2. Comparison of gas chromatography/isotope ratio mass spectrometry and liquid chromatography/isotope ratio mass spectrometry for carbon stable-isotope analysis of carbohydrates.

    Science.gov (United States)

    Moerdijk-Poortvliet, Tanja C W; Schierbeek, Henk; Houtekamer, Marco; van Engeland, Tom; Derrien, Delphine; Stal, Lucas J; Boschker, Henricus T S

    2015-07-15

    We compared gas chromatography/isotope ratio mass spectrometry (GC/IRMS) and liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) for the measurement of δ(13)C values in carbohydrates. Contrary to GC/IRMS, no derivatisation is needed for LC/IRMS analysis of carbohydrates. Hence, although LC/IRMS is expected to be more accurate and precise, no direct comparison has been reported. GC/IRMS with the aldonitrile penta-acetate (ANPA) derivatisation method was compared with LC/IRMS without derivatisation. A large number of glucose standards and a variety of natural samples were analysed for five neutral carbohydrates at natural abundance as well as at (13)C-enriched levels. Gas chromatography/chemical ionisation mass spectrometry (GC/CIMS) was applied to check for incomplete derivatisation of the carbohydrate, which would impair the accuracy of the GC/IRMS method. The LC/IRMS technique provided excellent precision (±0.08‰ and ±3.1‰ at natural abundance and enrichment levels, respectively) for the glucose standards and this technique proved to be superior to GC/IRMS (±0.62‰ and ±19.8‰ at natural abundance and enrichment levels, respectively). For GC/IRMS measurements the derivatisation correction and the conversion of carbohydrates into CO2 had a considerable effect on the measured δ(13)C values. However, we did not find any significant differences in the accuracy of the two techniques over the full range of natural δ(13)C abundances and (13)C-labelled glucose. The difference in the performance of GC/IRMS and LC/IRMS diminished when the δ(13)C values were measured in natural samples, because the chromatographic performance and background correction became critical factors, particularly for LC/IRMS. The derivatisation of carbohydrates for the GC/IRMS method was complete. Although both LC/IRMS and GC/IRMS are reliable techniques for compound-specific stable carbon isotope analysis of carbohydrates (provided that derivatisation is complete and the

  3. Isotope-dilution TurboFlow-LC-MS/MS method for simultaneous quantification of ten steroid metabolites in serum

    DEFF Research Database (Denmark)

    Søeborg, Tue; Frederiksen, Hanne; Johannsen, Trine Holm

    2017-01-01

    An isotope-dilution TurboFlow-LC-MS/MS method for simultaneous quantification of the ten steroid metabolites dehydroepiandrosterone sulfate (DHEAS), progesterone, 17α-hydroxyprogesterone (17-OHP), Δ4-androstenedione (Adione), corticosterone, 11-deoxycortisol, cortisol, cortisone, testosterone (T)...... possible only to include some of these analytes for specific diagnostic purposes which make the new method an extremely useful tool in the clinical laboratory....

  4. Direct determination of mercury in cosmetic samples by isotope dilution inductively coupled plasma mass spectrometry after dissolution with formic acid

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Ying; Shi, Zeming; Zong, Qinxia; Wu, Peng; Su, Jing [Sichuan Provincial Key Laboratory of Nuclear Technology in Geology, College of Nuclear Technology and Automation Engineering, Chengdu University of Technology, Chengdu 610059 (China); Liu, Rui, E-mail: liur.ray@gmail.com [Mineral Resources Chemistry Key Laboratory of Sichuan Higher Education Institutions, College of Materials and Chemistry and Chemical Engineering, Chengdu University of Technology, Chengdu 610059 (China)

    2014-02-17

    Graphical abstract: -- Highlights: •Simple, sensitive, and accurate method is established for mercury determination in cosmetics. •The sample preparation procedure is highly simplified. •Isotope dilution efficiently eliminates matrix effect. •First report of using formic acid based method in combination with PVG-ID-ICP MS for mercury quantitation in cosmetics. -- Abstract: A new method was proposed for the accurate determination of mercury in cosmetic samples based on isotopic dilution (ID)-photochemical vapor generation (PVG)-inductively coupled plasma mass spectrometry (ICP MS) measurement. Cosmetic samples were directly dissolved in formic acid solution and subsequently subjected to PVG for the reduction of mercury into vapor species following by ICP MS detection. Therefore, the risks of analyte contamination and loss were avoided. Highly enriched {sup 201}Hg isotopic spike is added to cosmetics and the isotope ratios of {sup 201}Hg/{sup 202}Hg were measured for the quantitation of mercury. With ID calibration, the influences originating from sample matrixes for the determination of mercury in cosmetic samples have been efficiently eliminated. The effects of several experimental parameters, such as the concentration of the formic acid, and the flow rates of carrier gas and sample were investigated. The method provided good reproducibility and the detection limits were found to be 0.6 pg mL{sup −1}. Finally, the developed method was successfully applied for the determination of mercury in six cosmetic samples and a spike test was performed to verify the accuracy of the method.

  5. Direct determination of halogens in powdered geological and environmental samples using isotope dilution laser ablation ICP-MS

    Science.gov (United States)

    Boulyga, Sergei F.; Heumann, Klaus G.

    2005-04-01

    Laser ablation inductively coupled plasma isotope dilution mass spectrometry (LA-ICP-IDMS) with a special laser ablation system for bulk analyses (LINA-Spark(TM)-Atomiser) was applied for direct determinations of chlorine, bromine, and iodine in rock and sediment samples. Special attention was focused on possible inter-halogen fractionations and analyte/spike isotope fractionations by using LA-ICP-MS and LA-ICP-IDMS, respectively. A variation of Br/Cl and I/Cl element intensity ratios by a factor of 1.3-3 was observed when changing the nebulizer gas flow rate in the range of 0.84-1.0 L min-1 and the laser power density in the range of 2-10 GW cm-2, respectively. When using an internal standard for halogen quantification in LA-ICP-MS, this inter-element fractionation can cause systematic errors, which can be avoided by applying the isotope dilution technique. However, at high laser power densities (>5.7 GW cm-2 for iodine and >4.0 GW cm-2 for bromine and chlorine) the corresponding measured isotope ratio of the isotope-diluted sample deviates significantly from the target value. Under optimised conditions concentrations in the range of 30 [mu]g g-1-16 × 103 [mu]g g-1 for chlorine, <2-140 [mu]g g-1 for bromine, and <0.1-31 [mu]g g-1 for iodine were determined by LA-ICP-IDMS in two sediment reference materials (SRM 1646, SRM 2704) and three rock reference samples (GS-N, Granite; BX-N, Bauxite; DT-N, Disthene), which have not been certified for these halogens. The sediment results agree well within the given uncertainties with indicative values by different methods and the results of the rock samples with those obtained by negative thermal ionisation isotope dilution mass spectrometry. The detection limits of LA-ICP-IDMS are 8 [mu]g g-1 for chlorine, 1.7 [mu]g g-1 for bromine, and 0.1 [mu]g g-1 for iodine.

  6. Stable isotope dilution HILIC-MS/MS method for accurate quantification of glutamic acid, glutamine, pyroglutamic acid, GABA and theanine in mouse brain tissues.

    Science.gov (United States)

    Inoue, Koichi; Miyazaki, Yasuto; Unno, Keiko; Min, Jun Zhe; Todoroki, Kenichiro; Toyo'oka, Toshimasa

    2016-01-01

    In this study, we developed the stable isotope dilution hydrophilic interaction liquid chromatography with tandem mass spectrometry (HILIC-MS/MS) technique for the accurate, reasonable and simultaneous quantification of glutamic acid (Glu), glutamine (Gln), pyroglutamic acid (pGlu), γ-aminobutyric acid (GABA) and theanine in mouse brain tissues. The quantification of these analytes was accomplished using stable isotope internal standards and the HILIC separating mode to fully correct the intramolecular cyclization during the electrospray ionization. It was shown that linear calibrations were available with high coefficients of correlation (r(2)  > 0.999, range from 10 pmol/mL to 50 mol/mL). For application of the theanine intake, the determination of Glu, Gln, pGlu, GABA and theanine in the hippocampus and central cortex tissues was performed based on our developed method. In the region of the hippocampus, the concentration levels of Glu and pGlu were significantly reduced during reality-based theanine intake. Conversely, the concentration level of GABA increased. This result showed that transited theanine has an effect on the metabolic balance of Glu analogs in the hippocampus.

  7. Simultaneous determination of PPCPs, EDCs, and artificial sweeteners in environmental water samples using a single-step SPE coupled with HPLC-MS/MS and isotope dilution.

    Science.gov (United States)

    Tran, Ngoc Han; Hu, Jiangyong; Ong, Say Leong

    2013-09-15

    A high-throughput method for the simultaneous determination of 24 pharmaceuticals and personal care products (PPCPs), endocrine disrupting chemicals (EDCs) and artificial sweeteners (ASs) was developed. The method was based on a single-step solid phase extraction (SPE) coupled with high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) and isotope dilution. In this study, a single-step SPE procedure was optimized for simultaneous extraction of all target analytes. Good recoveries (≥ 70%) were observed for all target analytes when extraction was performed using Chromabond(®) HR-X (500 mg, 6 mL) cartridges under acidic condition (pH 2). HPLC-MS/MS parameters were optimized for the simultaneous analysis of 24 PPCPs, EDCs and ASs in a single injection. Quantification was performed by using 13 isotopically labeled internal standards (ILIS), which allows correcting efficiently the loss of the analytes during SPE procedure, matrix effects during HPLC-MS/MS and fluctuation in MS/MS signal intensity due to instrument. Method quantification limit (MQL) for most of the target analytes was below 10 ng/L in all water samples. The method was successfully applied for the simultaneous determination of PPCPs, EDCs and ASs in raw wastewater, surface water and groundwater samples collected in a local catchment area in Singapore. In conclusion, the developed method provided a valuable tool for investigating the occurrence, behavior, transport, and the fate of PPCPs, EDCs and ASs in the aquatic environment.

  8. Experimental design for TBT quantification by isotope dilution SPE-GC-ICP-MS under the European water framework directive.

    Science.gov (United States)

    Alasonati, Enrica; Fabbri, Barbara; Fettig, Ina; Yardin, Catherine; Del Castillo Busto, Maria Estela; Richter, Janine; Philipp, Rosemarie; Fisicaro, Paola

    2015-03-01

    In Europe the maximum allowable concentration for tributyltin (TBT) compounds in surface water has been regulated by the water framework directive (WFD) and daughter directive that impose a limit of 0.2 ng L(-1) in whole water (as tributyltin cation). Despite the large number of different methodologies for the quantification of organotin species developed in the last two decades, standardised analytical methods at required concentration level do not exist. TBT quantification at picogram level requires efficient and accurate sample preparation and preconcentration, and maximum care to avoid blank contamination. To meet the WFD requirement, a method for the quantification of TBT in mineral water at environmental quality standard (EQS) level, based on solid phase extraction (SPE), was developed and optimised. The quantification was done using species-specific isotope dilution (SSID) followed by gas chromatography (GC) coupled to inductively coupled plasma mass spectrometry (ICP-MS). The analytical process was optimised using a design of experiment (DOE) based on a factorial fractionary plan. The DOE allowed to evaluate 3 qualitative factors (type of stationary phase and eluent, phase mass and eluent volume, pH and analyte ethylation procedure) for a total of 13 levels studied, and a sample volume in the range of 250-1000 mL. Four different models fitting the results were defined and evaluated with statistic tools: one of them was selected and optimised to find the best procedural conditions. C18 phase was found to be the best stationary phase for SPE experiments. The 4 solvents tested with C18, the pH and ethylation conditions, the mass of the phases, the volume of the eluents and the sample volume can all be optimal, but depending on their respective combination. For that reason, the equation of the model conceived in this work is a useful decisional tool for the planning of experiments, because it can be applied to predict the TBT mass fraction recovery when the

  9. Mass spectrometric profiling of Bacillus cereus strains and quantitation of the emetic toxin cereulide by means of stable isotope dilution analysis and HEp-2 bioassay.

    Science.gov (United States)

    Stark, Timo; Marxen, Sandra; Rütschle, Andrea; Lücking, Genia; Scherer, Siegfried; Ehling-Schulz, Monika; Hofmann, Thomas

    2013-01-01

    A fast and robust high-throughput ultra-performance liquid chromatography/time-of-flight mass spectrometry (UPLC-TOF MS) profiling method was developed and successfully applied to discriminate a total of 78 Bacillus cereus strains into no/low, medium and high producers of the emetic toxin cereulide. The data obtained by UPLC-TOF MS profiling were confirmed by absolute quantitation of cereulide in selected samples by means of high-performance liquid chromatography with tandem mass spectrometry (HPLC-MS/MS) and stable isotope dilution assay (SIDA). Interestingly, the B. cereus strains isolated from four vomit samples and five faeces samples from patients showing symptoms of intoxication were among the group of medium or high producers. Comparison of HEp-2 bioassay data with those determined by means of mass spectrometry showed differences, most likely because the HEp-2 bioassay is based on the toxic action of cereulide towards mitochondria of eukaryotic cells rather than on a direct measurement of the toxin. In conclusion, the UPLC-electrospray ionization (ESI)-TOF MS and the HPLC-ESI-MS/MS-SIDA analyses seem to be promising tools for the robust high-throughput analysis of cereulide in B. cereus cultures, foods and other biological samples.

  10. NUCLEAR ISOTOPIC DILUTION OF HIGHLY ENRICHED URANIUM BY DRY BLENDING VIA THE RM-2 MILL TECHNOLOGY

    Energy Technology Data Exchange (ETDEWEB)

    Raj K. Rajamani; Sanjeeva Latchireddi; Vikas Devrani; Harappan Sethi; Roger Henry; Nate Chipman

    2003-08-01

    DOE has initiated numerous activities to focus on identifying material management strategies to disposition various excess fissile materials. In particular the INEEL has stored 1,700 Kg of offspec HEU at INTEC in CPP-651 vault facility. Currently, the proposed strategies for dispositioning are (a) aqueous dissolution and down blending to LEU via facilities at SRS followed by shipment of the liquid LEU to NFS for fabrication into LWR fuel for the TVA reactors and (b) dilution of the HEU to 0.9% for discard as a waste stream that would no longer have a criticality or proliferation risk without being processed through some type of enrichment system. Dispositioning this inventory as a waste stream via aqueous processing at SRS has been determined to be too costly. Thus, dry blending is the only proposed disposal process for the uranium oxide materials in the CPP-651 vault. Isotopic dilution of HEU to typically less than 20% by dry blending is the key to solving the dispositioning issue (i.e., proliferation) posed by HEU stored at INEEL. RM-2 mill is a technology developed and successfully tested for producing ultra-fine particles by dry grinding. Grinding action in RM-2 mill produces a two million-fold increase in the number of particles being blended in a centrifugal field. In a previous study, the concept of achieving complete and adequate blending and mixing (i.e., no methods were identified to easily separate and concentrate one titanium compound from the other) in remarkably short processing times was successfully tested with surrogate materials (titanium dioxide and titanium mono-oxide) with different particle sizes, hardness and densities. In the current project, the RM-2 milling technology was thoroughly tested with mixtures of natural uranium oxide (NU) and depleted uranium oxide (DU) stock to prove its performance. The effects of mill operating and design variables on the blending of NU/DU oxides were evaluated. First, NU and DU both made of the same oxide

  11. A versatile method for stable carbon isotope analysis of carbohydrates by high-performance liquid chromatography/isotope ratio mass spectrometry

    NARCIS (Netherlands)

    Boschker, H.T.S.; Moerdijk-Poortvliet, T.C.W.; Van Breugel, P.; Houtekamer, M.J.; Middelburg, J.J.

    2008-01-01

    We have developed a method to analyze stable carbon isotope (13C/12C) ratios in a variety of carbohydrates using high-performance liquid chromatography/isotope ratio mass spectrometry (HPLC/IRMS). The chromatography is based on strong anion-exchange columns with low strength NaOH eluents. An eluent

  12. Chemical Synthesis of Deoxynivalenol-3-β-d-[13C6]-glucoside and Application in Stable Isotope Dilution Assays

    Directory of Open Access Journals (Sweden)

    Katharina Habler

    2016-06-01

    Full Text Available Modified mycotoxins have been gaining importance in recent years and present a certain challenge in LC-MS/MS analysis. Due to the previous lack of a labeled isotopologue of the modified mycotoxin deoxynivalenol-3-glucoside, in our study we synthesized the first 13C-labeled internal standard. Therefore, we used the Königs-Knorr method to synthesize deoxynivalenol-3-β-d-[13C6]-glucoside originated from unlabeled deoxynivalenol and [13C6]-labeled glucose. Using the synthesized isotopically-labeled standard deoxynivalenol-3-β-d-[13C6]-glucoside and the purchased labeled standard [13C15]-deoxynivalenol, a stable isotope dilution LC-MS/MS method was firstly developed for deoxynivalenol-3-glucoside and deoxynivalenol in beer. The preparation and purification of beer samples was based on a solid phase extraction. The validation data of the newly developed method gave satisfying results. Intra- and interday precision studies revealed relative standard deviations below 0.5% and 7%, respectively. The recoveries ranged for both analytes between 97% and 112%. The stable isotope dilution assay was applied to various beer samples from four different countries. In summary, deoxynivalenol-3-glucoside and deoxynivalenol mostly appeared together in varying molar ratios but were quantified in rather low contents in the investigated beers.

  13. Determination of lead, uranium, thorium, and thallium in silicate glass standard materials by isotope dilution mass spectrometry

    Science.gov (United States)

    Barnes, I.L.; Garner, E.L.; Gramlich, J.W.; Moore, L.J.; Murphy, T.J.; Machlan, L.A.; Shields, W.R.; Tatsumoto, M.; Knight, R.J.

    1973-01-01

    A set of four standard glasses has been prepared which have been doped with 61 different elements at the 500-, 50-, 1-, and 0.02-ppm level. The concentrations of lead, uranium, thorium, and thallium have been determined by isotope dilution mass spectrometry at a number of points in each of the glasses. The results obtained from independent determinations in two laboratories demonstrate the homogeneity of the samples and that precision of the order of 0.5% (95% L.E.) may be obtained by the method even at the 20-ppb level for these elements. The chemical and mass spectrometric procedures necessary are presented.

  14. Development of SI-traceable C-peptide certified reference material NMIJ CRM 6901-a using isotope-dilution mass spectrometry-based amino acid analyses.

    Science.gov (United States)

    Kinumi, Tomoya; Goto, Mari; Eyama, Sakae; Kato, Megumi; Kasama, Takeshi; Takatsu, Akiko

    2012-07-01

    A certified reference material (CRM) is a higher-order calibration material used to enable a traceable analysis. This paper describes the development of a C-peptide CRM (NMIJ CRM 6901-a) by the National Metrology Institute of Japan using two independent methods for amino acid analysis based on isotope-dilution mass spectrometry. C-peptide is a 31-mer peptide that is utilized for the evaluation of β-cell function in the pancreas in clinical testing. This CRM is a lyophilized synthetic peptide having the human C-peptide sequence, and contains deamidated and pyroglutamylated forms of C-peptide. By adding water (1.00 ± 0.01) g into the vial containing the CRM, the C-peptide solution in 10 mM phosphate buffer saline (pH 6.6) is reconstituted. We assigned two certified values that represent the concentrations of total C-peptide (mixture of C-peptide, deamidated C-peptide, and pyroglutamylated C-peptide) and C-peptide. The certified concentration of total C-peptide was determined by two amino acid analyses using pre-column derivatization liquid chromatography-mass spectrometry and hydrophilic chromatography-mass spectrometry following acid hydrolysis. The certified concentration of C-peptide was determined by multiplying the concentration of total C-peptide by the ratio of the relative area of C-peptide to that of the total C-peptide measured by liquid chromatography. The certified value of C-peptide (80.7 ± 5.0) mg/L represents the concentration of the specific entity of C-peptide; on the other hand, the certified value of total C-peptide, (81.7 ± 5.1) mg/L can be used for analyses that does not differentiate deamidated and pyroglutamylated C-peptide from C-peptide itself, such as amino acid analyses and immunochemical assays.

  15. Determination of the threshold odor concentration of main odorants in essential oils using gas chromatography-olfactometry incremental dilution technique.

    Science.gov (United States)

    Benzo, Maurizio; Gilardoni, Gianluca; Gandini, Carlo; Caccialanza, Gabriele; Vita Finzi, Paola; Vidari, Giovanni; Abdo, Susana; Layedra, Patricia

    2007-05-25

    An essential oil, obtained by steam distillation of Clinopodium tomentosum (Kunth) Govaerts (Lamiaceae), collected in Ecuador, was analyzed by gas chromatography-olfactometry (GC-O) and GC-MS techniques. To our knowledge, the composition of this essential oil is described here for the first time, both from the chemical and olfactometric viewpoints. A preliminary analysis by GC-MS and using Kovats' retention indexes, lead to characterize and quantify the oil constituents, while GC-O was then applied for the identification of the main odorants. By the incremental dilution method (AEDA, CHARM Analysis), applied to the GC-O technique, the flavor dilution (FD) chromatogram was obtained. In order to calculate the TOC values of the main odorants, the relationship between the odorant concentration at the sniffing port and that one in the injected solution was established. This relationship was calculated by comparing the injected amount with the TOC value of a reference compound (limonene), obtained by dynamic dilution olfactometry. A good agreement was found between calculated and measured TOC values of few odorants.

  16. Determination of Characteristic Components in Essential Oils from Wisteria brachybotrys Using Gas Chromatography-Olfactometry Incremental Dilution Technique

    Directory of Open Access Journals (Sweden)

    Mitsuo Miyazawa

    2011-01-01

    Full Text Available The essential oil, obtained by steam distillation of flowers, leaves and stems from Wisteria brachybotrys Sieb.et Zucc, collected in Japan was analyzed by gas chromatography (GC and GC-MS. The important aroma-active compounds were also detected in the oil using GC-MS/Olfactometry (GC-MS/O and aroma extraction dilution analysis (AEDA. As a result, sixty-eight compounds from flowers of W. brachybotrys, accounting for 96.3%, were identified, and benzyl cyanide (31.7%, palmitic acid (8.7%, and (Z- g -bisabolene (8.4% as the main compounds. Thirty compounds from leaves, accounting for 97.3%, were identified, and phytol (46.0%, palmitic acid (8.2%, and nonanal (5.7% as the main compounds. Twenty-eight compounds from stems, accounting for 98.7%, were identified, and geraniol (32.8%, linalool (22.1%, and nerol (10.4% as the main compounds. A preliminary analysis by GC-MS and using Kovats’ retention indexes, lead to characterize and quantify the oil constituents, while GC-MS/O was then applied for the identification of the main odorants. By the incremental dilution method (AEDA, applied to the GC-MS/O technique, the flavor dilution (FD factor was obtained. To our knowledge, the composition of these parts of essential oils is described here for the first time, both from the chemical and olfactometric viewpoints.

  17. Analysis of ochratoxin A in grapes, musts and wines by LC–MS/MS: First comparison of stable isotope dilution assay and diastereomeric dilution assay methods

    Energy Technology Data Exchange (ETDEWEB)

    Roland, Aurélie, E-mail: aurelie@nyseos.fr [Nyseos, 2 place Pierre Viala, Montpellier Cedex 1 34060 (France); Bros, Pauline, E-mail: pauline.bros@gmail.com [Institut Français de la Vigne et du Vin, UMT Qualinnov, 2 place Pierre Viala, Montpellier Cedex 1 34060 (France); Bouisseau, Anaïs, E-mail: anais.bouisseau@gmail.com [Nyseos, 2 place Pierre Viala, Montpellier Cedex 1 34060 (France); Institut des Biomolécules Max Mousseron, UMR-CNRS-5247, Universités Montpellier I and II, Place Eugène Bataillon, 34095 Montpellier (France); Cavelier, Florine, E-mail: florine@univ-montp2.fr [Institut des Biomolécules Max Mousseron, UMR-CNRS-5247, Universités Montpellier I and II, Place Eugène Bataillon, 34095 Montpellier (France); Schneider, Rémi, E-mail: remi.schneider@vignevin.com [Institut Français de la Vigne et du Vin, UMT Qualinnov, 2 place Pierre Viala, Montpellier Cedex 1 34060 (France)

    2014-03-01

    Highlights: • OTA extraction on immunoaffinity columns is not adapted for DIDA quantification. • The use of a labeled internal standard is compulsory to obtain reliable results. • SIDA and DIDA quantification approaches have been compared for the first time. Abstract: Ochratoxin A (OTA) exhibits potent nephrotoxic, carcinogenic and teratogenic effects and its maximum level in wines has been set to 2 μg L⁻¹ by regulation. Consequently, the analytical procedures for OTA determination in wines have to be both very sensitive and reliable. In this paper, we compared two quantification methods: the stable isotope dilution assay (SIDA) and the diastereomeric dilution assay (DIDA). For this purpose, non-natural analogues of OTA were synthesized: the labeled OTA (OTA-d₄) as a diastereomeric mixture for the SIDA and one non-natural OTA’s diastereomer (OTA-dia) for the DIDA. To quantify OTA in red grapes, musts or wines, the sample preparation was optimized using immunoaffinity column extraction and the analysis was performed by LC–MS/MS in Multiple Reaction Monitoring mode. A validation procedure in agreement with the International Organization of Vine and Wine recommendations was conducted. It appeared that SIDA quantification exhibited excellent sensitivity (LOD < 1 ng L⁻¹), accuracy (recovery = 98%), repeatability (RSD < 3%) and intermediate reproducibility (RSD < 4%) compared to quantification by DIDA. Indeed, DIDA method did not provide satisfactory results demonstrating that immunoaffinity extraction is exclusively selective for the natural OTA and not for its diastereomer, which therefore cannot be considered as a good internal standard for this particular method.

  18. Isotope Ratio Monitoring Gas Chromatography Mass Spectrometry (IRM-GCMS)

    Science.gov (United States)

    Freeman, K. H.; Ricci, S. A.; Studley, A.; Hayes, J. M.

    1989-01-01

    On Earth, the C-13 content of organic compounds is depleted by roughly 13 to 23 permil from atmospheric carbon dioxide. This difference is largely due to isotope effects associated with the fixation of inorganic carbon by photosynthetic organisms. If life once existed on Mars, then it is reasonable to expect to observe a similar fractionation. Although the strongly oxidizing conditions on the surface of Mars make preservation of ancient organic material unlikely, carbon-isotope evidence for the existence of life on Mars may still be preserved. Carbon depleted in C-13 could be preserved either in organic compounds within buried sediments, or in carbonate minerals produced by the oxidation of organic material. A technique is introduced for rapid and precise measurement of the C-13 contents of individual organic compounds. A gas chromatograph is coupled to an isotope-ratio mass spectrometer through a combustion interface, enabling on-line isotopic analysis of isolated compounds. The isotope ratios are determined by integration of ion currents over the course of each chromatographic peak. Software incorporates automatic peak determination, corrections for background, and deconvolution of overlapped peaks. Overall performance of the instrument was evaluated by the analysis of a mixture of high purity n-alkanes of know isotopic composition. Isotopic values measured via IRM-GCMS averaged withing 0.55 permil of their conventionally measured values.

  19. Development and application of liquid chromatography coupled to isotope ratio mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Lijun

    2014-02-19

    Stable isotope analysis has found widespread applications in various disciplines such as archaeology, geochemistry, biology, food authenticity, and forensic science. Coupling chromatography to isotope ratio mass spectrometry for compound-specific isotope analysis (CSIA) is a trend, as it provides several advantages over bulk isotope analysis, e.g., relatively simple sample preparation, the ability to measure individual compounds in a complex mixture in one run, and the reduced sample size required for precise isotope analysis. Gas chromatography coupled to isotope ratio mass spectrometry (GC/IRMS) has been well-established for compound-specific isotope analysis of volatile organic compounds within the last two decades. However, an interface combining liquid chromatography with isotope ratio mass spectrometry (LC/IRMS) was not commercially available until 2004. The current design of the interface requires using a carbon-free eluent in chromatographic separation. This requirement limits the application of the most frequently used reversed-phase liquid chromatography in CSIA, because the elution strength of water at room temperature is too low to serve as mobile phase in reversed-phase separations. In order to increase the elution strength of water, we propose using high temperature water for chromatographic elution. The polarity of water decreases with an increase of temperature, yielding increased elution strength in reversed-phase columns. Therefore, high temperature water can be used as eluent instead of organic solvent for combining reversed-phase liquid chromatography with isotope ratio mass spectrometry (RPLC/IRMS). Additionally, temperature gradients can replace organic solvent gradients to increase chromatographic resolution. This is very important for LC/IRMS analysis, as precise isotope analysis requires baseline separation of analytes. In this thesis, high-temperature reversed-phase liquid chromatography was coupled to, and for the first time carefully

  20. Determination of testosterone propionate residues in fish and shrimp by high pressure liquid chromatography-tandem mass spectrometry with isotope dilution%同位素稀释高压液相色谱-串联质谱法测定鱼虾中丙酸睾酮残留量

    Institute of Scientific and Technical Information of China (English)

    田良良; 林洪; 曹立民; 蔡友琼; 王建华; 黄冬梅; 史永富

    2014-01-01

    Objective A rapid, specific and highly sensitive method for the determination of testosterone propio-nateresidue in fish and shrimp was developed using high pressure liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). Methods Homogenized tissue samples which were added with nandrolone-D3 were extracted by tert-butyl ether under ultrasonication and cleaned up with freezing and high-speed centrifugation. The target compounds were separated on Eclipse Plus C18 (100 mm×2.1 mm, 3μm) using acetonitrile-0.1%formic acid as mobile phase at a flow rate of 0.3 mL/min, and detected qualitatively and quantitatively in selected reaction monitoring(SRM) under posi-tive mode. Results The linearity ranged from 0.5 to 100 ng/mL and correlation coefficient was 0.9989. The limit of quantitation (LOQ) was 0.5μg/kg. At the spiked levels of 0.5, 1.0, 2.0μg/kg and 10.0μg/kg, the average recoveries ranged from 71.2% to 104.5%. The relative standard deviations were between 2.26% and 5.65%. Conclusion The method is simple, sensitive and accurate for detecting the testosterone propionate in aquatic products.%目的:采用高压液相色谱-串联质谱(high pressure liquid chromatography-tandem mass spectrometry, HPLC-MS/MS)快速检测鱼虾等水产品中丙酸睾酮残留。方法向捣碎匀浆后的样品中加入内标诺龙-D3混匀后,叔丁基甲醚超声提取,-80℃冷冻30 min后12000 r/min离心净化。以Eclipse Plus C18为色谱分离柱,以乙腈-0.1%甲酸水溶液为流动相,流速为0.3 mL/min,采用三重四极杆质谱在正离子模式下进行选择反应离子监测。结果丙酸睾酮在0.5~100 ng/mL范围内呈线性关系,相关系数为0.9989;方法定量限为0.5μg/kg。当添加水平为0.5~10.0μg/kg时,平均回收率为71.2%~104.5%,相对标准偏差为2.26%~5.65%。结论该方法操作简单、快速、灵敏度高,适用于快速检测水产品中丙酸睾酮的残留量。

  1. Determination of lead, cadmium and thallium in water samples at ppb and ppt-levels by isotope dilution mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Trettenbach, J.; Heumann, K.G.

    1985-10-01

    An analytical procedure by isotope dilution mass spectrometry for the simultaneous determination of lead, cadmium and thallium traces in water samples down to the ppt-level is described. As a definitive method this type of analysis is especially advantageous to calibrate other analytical methods. A cathodic electrodeposition is used for the separation of the analysed heavy metals. A spike solution containing SWPb, WCd and STTl is applied for the isotope dilution technique. Positive thermal ions of the elements are successively measured by increasing the temperature of the filament in a single-filament ion source. The blank contribution of chemicals of different degree of purity for the analytical procedure was investigated. Different spring water samples dependent on the type of soil were analysed. Drinking water samples showed a significant difference in the heavy metal concentration dependent on the frequency in which the water-pipe was used. In this case, thallium is an especially sensitive indicator. It has been found for lead and cadmium that in contrast to thallium a high portion of both elements is fixed at small particles which can be included in the drinking water or is adsorbed at the surface of a quartz vessel. (orig.).

  2. Isotope dilution HPLC-MS/MS for simultaneous quantification of acrylamide and 5-hydroxymethylfurfural (HMF) in thermally processed seafood.

    Science.gov (United States)

    Qin, Lei; Zhang, Yu-Ying; Xu, Xian-Bing; Wang, Xu-Song; Liu, Hong-Wei; Zhou, Da-Yong; Zhu, Bei-Wei; Thornton, Megan

    2017-10-01

    The objective of this study was to develop an accurate, robust and rapid HPLC-MS/MS-based method capable of quantifying acrylamide and 5-hydroxymethylfurfural (HMF) simultaneously. A Phenomenex Synergi Fusion-RP C18 column (50mm×2.5mm, 2μm) was used, and the MS/MS instrument was operated in multiple reaction monitoring mode. The isotope dilution method was used to correct for the matrix effect from samples. This method demonstrated low limits of quantification (2.12ng/mL for acrylamide and 4.86ng/mL for HMF) and excellent linearity (R(2)>0.999). This method also demonstrated excellent quantification accuracy, precision, and recovery (87-110%). Using the method developed, target analytes were quantified in 14 thermally-processed seafood samples. Resulting concentrations ranged from 5.58 to 50.35μg/kg for acrylamide, and from 12.54 to 2276.44μg/kg for HMF. The proposed isotope dilution HPLC-MS/MS method is a valid and rapid technique for simultaneous analysis of acrylamide and HMF in seafood. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Accurate measurements of {sup 129}I concentration by isotope dilution using MC-ICPMS for half-life determination

    Energy Technology Data Exchange (ETDEWEB)

    Isnard, Helene; Nonell, Anthony; Marie, Mylene [Commissariat a l' Energie Atomique et aux Energies alternatives (CEA), Gif Sur Yvette (France). DEN, DPC, SEARS, LANIE; Chartier, Frederic [Commissariat a l' Energie Atomique et aux Energies alternatives (CEA), Gif Sur Yvette (France). DEN, DPC

    2016-05-01

    Determining the {sup 129}I concentration, a long-lived radionuclide present in spent nuclear fuel, is a major issue for nuclear waste disposal purpose. {sup 129}I also has to be measured in numerous environmental, nuclear and biological samples. To be able to accurately determine the {sup 129}I concentration, an analytical method based on the use of a multicollector-inductively coupled plasma mass spectrometer (MC-ICPMS) combined with an isotope dilution technique using an {sup 127}I spike, was developed. First, the influence of different media (HNO{sub 3}, NaOH and TMAH) on natural {sup 127}I signal intensity and stability and on memory effects was studied. Then an analytical procedure was developed by taking into account the correction of blanks and interferences. Tellurium was chosen for instrumental mass bias correction, as no certified standards with suitable {sup 127}I/{sup 129}I ratio are available. Finally, the results, reproducibility and uncertainties obtained for the {sup 129}I concentration determined by isotope dilution with a {sup 127}I spike are presented and discussed. The final expanded relative uncertainty obtained for the iodine-129 concentration was lower than 0.7% (k = 1). This precise {sup 129}I determination in association with further activity measurements of this nuclide on the same sample will render it possible to determine a new value of the {sup 129}I half-life with a reduced uncertainty (0.76%, k = 1).

  4. An Isotopic Dilution Experiment Using Liquid Scintillation: A Simple Two-System, Two-Phase Analysis.

    Science.gov (United States)

    Moehs, Peter J.; Levine, Samuel

    1982-01-01

    A simple isotonic, dilution analysis whose principles apply to methods of more complex radioanalyses is described. Suitable for clinical and instrumental analysis chemistry students, experimental manipulations are kept to a minimum involving only aqueous extraction before counting. Background information, procedures, and results are discussed.…

  5. Determination of mercury in coal by isotope dilution cold-vapor generation inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Long, Stephen E; Kelly, W Robert

    2002-04-01

    A method based on isotope dilution cold-vapor inductively coupled plasma mass spectrometry (ID-CV-ICPMS) has been developed for high-accuracy determinations of mercury in bituminous and sub-bituminous coals. A closed-system digestion process employing a Carius tube is used to completely oxidize the coal matrix and chemically equilibrate the mercury in the sample with a 201Hg isotopic spike. The digestates are diluted with high-purity quartz-distilled water, and the mercury is released as a vapor by reduction with tin(II) chloride. Measurements of 201Hg/202Hg isotope ratios are made using a quadrupole ICPMS system in time-resolved analysis mode. The new method has some significant advantages over existing methods. The instrument detection limit is less than 1 pg/mL. The average blank (n = 17) is 30 pg, which is roughly 1 order of magnitude lower than the equivalent microwave digestion procedure. The detection limit in coal is blank limited and is approximately 40 pg/g. Memory effects are very low. The relative reproducibility of the analytical measurements is approximately 0.5% for mercury concentrations in the range 10-150 ng/g. The method has been used to measure mercury concentrations in six coal reference materials, SRM 1632b (77.4 ng/g), SRM 1632c (94.3 ng/g), BCR 40 (433.2 ng/g), BCR 180 (125.0 ng/g), BCR 181 (135.8 ng/g), and SARM 20 (252.6 ng/g), as well as a coal fly ash, SRM 1633b (143.1 ng/g). The method is equally applicable to other types of fossil fuels including both crude and refined oils.

  6. Determination of mercury in coal by isotope dilution cold-vapor generation inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Long, S.E.; Kelly, W.R.

    2002-04-01

    A method based on isotope dilution cold-vapor inductively coupled plasma mass spectrometry (ID-CV-ICPMS) has been developed for high-accuracy determinations of mercury in bituminous and sub-bituminous coals. A closed-system digestion process employing a Carius tube is used to completely oxidize the coal matrix and chemically equilibrate the mercury in the sample with a Hg-201 isotopic spike. The digestates are diluted with high-purity quartz-distilled water, and the mercury is released as a vapor by reduction with tin chloride. Measurements of Hg-201/Hg-202 isotope ratios are made using a quadrupole ICPMS system in time-resolved analysis mode. The new method has some significant advantages over existing methods. The instrument detection limit is less than 1 pg/mL. The average blank (n = 17) is 30 pg, which is roughly 1 order of magnitude lower than the equivalent microwave digestion procedure. The detection limit in coal is blank limited and is similar to 40 pg/g. Memory effects are very low. The relative reproducibility of the analytical measurements is similar to 0.5% for mercury concentrations in the range 10-150 ng/g. The method has been used to measure mercury concentrations in six coal reference materials, SRM 1632b (77.4 ng/g), SRM 1632c (94.3 ng/g), BCR 40 (433.2 ng/g), BCR 180 (125.0 ng/g), BCR 181 (135.8 ng/g), and SARM 20 (252.6 ng/g), as well as a coal fly ash, SRM 1633b (143.1 ng/g). The method is equally applicable to other types of fossil fuels including both crude and refined oils.

  7. Isotope Dilution - Thermal Ionisation Mass Spectrometric Analysis for Tin in a Fly Ash Material; Analisis de Estano en una Ceniza de Combustion mediante Espectrometria de Masas de Ionizacion Termica con Dilucion Isotopica

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, C.; Fernandez, M.; Quejido, A. L.

    2006-07-01

    Isotope dilution-thermal ionisation mass spectrometry (ID-TIMS) analysis has been applied to the determination of tin in a fly ash sample supplied by the EC Joint Research Centre (Ispra, Italy). The proposed procedure includes the silica gel/phosphoric acid technique for tin thermal ionisation activation and a strict heating protocol for isotope ratio measurements. Instrumental mass discrimination factor has been previously determined measuring a natural tin standard solution. Spike solutions has been prepared from 112Sn-enriched metal and quantified by reverse isotope dilution analysis. Two sample aliquots were spiked and tin was extracted with 4,5 M HCI during 25 min ultrasound exposure time. Due to the complex matrix of this fly ash material, a two-step purification stage using ion-exchange chromatography was required prior TIMS analysis. Obtained results for the two sample-spike blends (10,10 + - 0,55 y 10,50 + - 0,64 imolg-1) are comprarable, both value and uncertainty. Also a good reproducibility is observed between measurements. The proposed ID-TIMS procedure, as a primary method and due to the lack of fly ash reference material certified for tin content, can be used to validate more routine methodologies applied to tin determination in this kind of materials. (Author) 75 refs.

  8. Isotope Fractionation in Methane Reactions Studied by Gas Chromatography and Liquid Scintillation

    DEFF Research Database (Denmark)

    Andersen, Bertel Lohmann; Bidoglio, G.; Leip, A.

    1997-01-01

    Determination of C-14-marked methane by gas chromatography and liquid scintillation counting is shown to be useful in studies of isotope effects. Data on the specific activity is used to separate the contributions of (CH4)-C-14, and (CH4)-C-12 to the gas-chromatographic peak area. As an application...

  9. Stable isotope dilution assay (SIDA) and HS-SPME-GCMS quantification of key aroma volatiles for fruit and sap of Australian mango cultivars.

    Science.gov (United States)

    San, Anh T; Joyce, Daryl C; Hofman, Peter J; Macnish, Andrew J; Webb, Richard I; Matovic, Nicolas J; Williams, Craig M; De Voss, James J; Wong, Siew H; Smyth, Heather E

    2017-04-15

    Reported herein is a high throughput method to quantify in a single analysis the key volatiles that contribute to the aroma of commercially significant mango cultivars grown in Australia. The method constitutes stable isotope dilution analysis (SIDA) in conjunction with headspace (HS) solid-phase microextraction (SPME) coupled with gas-chromatography mass spectrometry (GCMS). Deuterium labelled analogues of the target analytes were either purchased commercially or synthesised for use as internal standards. Seven volatiles, hexanal, 3-carene, α-terpinene, p-cymene, limonene, α-terpinolene and ethyl octanoate, were targeted. The resulting calibration functions had determination coefficients (R(2)) ranging from 0.93775 to 0.99741. High recovery efficiencies for spiked mango samples were also achieved. The method was applied to identify the key aroma volatile compounds produced by 'Kensington Pride' and 'B74' mango fruit and by 'Honey Gold' mango sap. This method represents a marked improvement over current methods for detecting and measuring concentrations of mango fruit and sap volatiles. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Lysozyme refolding at high concentration by dilution and size—exclusion chromatography

    Institute of Scientific and Technical Information of China (English)

    高永贵; 关怡新; 姚善泾; CHOMan-gi

    2003-01-01

    This study of renaturation by dilution and size exclusion chromstography(SEC) addition of urea to improve yield as well as the initial and final protein concentrations showed that although urea decreased the rate of lysozyme refolding,it could suppress protein aggregation to sustain the pathway of correct refolding at high protein concentration;and that there existed an optimum urea concentration in renaturation buffer.Under the above conditions,lysozyme was successfully refolded from initial concentration of up tp 40 mg/mL by dilu-tion and 100 mg/mL by SEC,with the yield of the former being more than 40% and that of the latter being 34.8%.Especislly,under the condition of 30 min iterval time,i.e.τ>2(tR2-tR1),the efficiency was increased by 25% and the renaturation buffer could be recycled for SEC refolding in continuous operation of downstream process.

  11. 同位素稀释-超高效液相色谱-串联质谱法同时测定精油中的7种雌性激素%Simultaneous determination of 7 female sex hormones in essential oil by high performance liquid chromatography- tandem mass spectrometry with isotope dilution

    Institute of Scientific and Technical Information of China (English)

    黄百芬; 韩铮; 徐小民; 蔡增轩; 姜维; 任一平

    2011-01-01

    建立了采用同位素稀释-超高效液相色谱-串联质谱同时快速测定精油中7种雌性激素(雌三醇、雌二醇、雌酮、炔雌醇、己二烯雌酚、己烷雌酚、己烯雌酚)的方法.样品中雌性激素用乙酸乙酯-正己烷(2∶98, v/v)溶液提取后,经硅胶固相萃取小柱净化,通过ACQUITY UPLCTM BEH SHELD RP18色谱柱(100 mm×2.1 mm, 1.7 μm)、以水-乙腈作流动相梯度洗脱对7种雌性激素进行分离,采用串联质谱在负离子扫描方式下通过多反应监测(MRM)模式进行定性定量分析.以雌三醇-D3、雌二醇-D3、己烯雌酚-D6为内标,有效减少了样品基质的影响.该方法对精油中7种雌激素的检出限(LOD)为0.3~7 μg/kg,定量限(LOQ)为1~20 μg/kg.待测物与内标物定量离子的峰面积比值与待测物的质量浓度在20~500 μg/L范围内呈良好的线性关系,相关系数(r2)均大于0.997;在20~500 μg/kg 范围内3个水平的加标平均回收率为88.5% ~114.8% ,日内精密度(以相对标准偏差计)(n=6)为4.8% ~18.9% .应用该方法对浙江杭州地区不同超市或美容院随机采集的12份精油样品进行测定的结果显示,有1份样品含有雌二醇和雌酮,其余11份样品均未检出雌性激素.%A reliable ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the simultaneous determination of 7 female sex hormones ( estriol,estradiol, estrone, ethinyloestradiol, dienestrol, hexestrol, diethylstilbestrol) in essential oil was developed. The sample was extracted by ethylacetate-normal hexane solution (2: 98, v/v)and the extract was purified by a silica solid phase extraction-based clean-up column. Then,the analytes were separated on an ACQUITY UPLC BEH SHELD RP18 column ( 100 mm × 2.1 mm, 1.7 μm) in gradient elution with the mobile phases of water and acetonitrile. The separated compounds were detected with a Waters Xevo TQ MS tandem quadrupole mass spectrometer operated in

  12. Simple and accurate measurement of carbamazepine in surface water by use of porous membrane-protected micro-solid-phase extraction coupled with isotope dilution mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Teo, Hui Ling [Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore 117528 (Singapore); Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore 117543 (Singapore); Wong, Lingkai [Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore 117528 (Singapore); Liu, Qinde, E-mail: liu_qinde@hsa.gov.sg [Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore 117528 (Singapore); Teo, Tang Lin; Lee, Tong Kooi [Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore 117528 (Singapore); Lee, Hian Kee, E-mail: chmleehk@nus.edu.sg [Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore 117543 (Singapore)

    2016-03-17

    To achieve fast and accurate analysis of carbamazepine in surface water, we developed a novel porous membrane-protected micro-solid-phase extraction (μ-SPE) method, followed by liquid chromatography-isotope dilution tandem mass spectrometry (LC-IDMS/MS) analysis. The μ-SPE device (∼0.8 × 1 cm) was fabricated by heat-sealing edges of a polypropylene membrane sheet to devise a bag enclosing the sorbent. The analytes (both carbamazepine and isotope-labelled carbamazepine) were first extracted by μ-SPE device in the sample (10 mL) via agitation, then desorbed in an organic solvent (1 mL) via ultrasonication. Several parameters such as organic solvent for pre-conditioning of μ-SPE device, amount of sorbent, adsorption time, and desorption solvent and time were investigated to optimize the μ-SPE efficiency. The optimized method has limits of detection and quantitation estimated to be 0.5 ng L{sup −1} and 1.6 ng L{sup −1}, respectively. Surface water samples spiked with different amounts of carbamazepine (close to 20, 500, and 1600 ng L{sup −1}, respectively) were analysed for the validation of method precision and accuracy. Good precision was obtained as demonstrated by relative standard deviations of 0.7% for the samples with concentrations of 500 and 1600 ng kg{sup −1}, and 5.8% for the sample with concentration of 20 ng kg{sup −1}. Good accuracy was also demonstrated by the relative recoveries in the range of 96.7%–103.5% for all samples with uncertainties of 1.1%–5.4%. Owing to the same chemical properties of carbamazepine and isotope-labelled carbamazepine, the isotope ratio in the μ-SPE procedure was accurately controlled. The use of μ-SPE coupled with IDMS analysis significantly facilitated the fast and accurate measurement of carbamazepine in surface water. - Highlights: • μ-SPE coupled with IDMS for the measurement of carbamazepine. • The method is the first report of coupling μ-SPE with IDMS. • μ-SPE is fast, time

  13. Isotope dilution-GC-MS/MS analysis of 16 polycyclic aromatic hydrocarbons in selected medicinal herbs used as health food additives.

    Science.gov (United States)

    Yu, L; Cao, Y; Zhang, J; Cui, Z; Sun, H

    2012-01-01

    Medicinal herbs have a very important role in health protection and disease control, and have been used in health foods. Polycyclic aromatic hydrocarbons (PAHs) have carcinogenic, biological and mutagenic effects. In this paper, the content of 16 PAHs as representative contaminants in nine Chinese medicinal herbs, as additives for health foods, was investigated in order to ensure food safety from this source. A highly sensitive isotope dilution-gas chromatography-tandem mass spectrometry (ID-GC-MS/MS) method combined with gel permeation chromatography (GPC) and solid-phase extraction (SPE) was developed. Calibration curves showed good linearity for all PAHs (R² > 0.999), and the limit of quantification (LOQ) ranged from 0.42 to 2.7 µg kg⁻¹. Average recoveries for these compounds were in the range of 52.5-117%, 52.6-119% and 81.4-108% at the concentrations of 10, 50 and 250 µg kg⁻¹ with RSD of 1.8-15%, 0.9-15% and 1.0-15%, respectively. The proposed method was used for the analysis of nine Chinese medicinal herbs. Total levels of PAHs varied from 98.2 µg kg⁻¹ (cassia seed) to 2245 µg kg⁻¹ (eucommia bark). The highest level was found for phenanthrene (Phe) in liquorice root (631.3 µg kg⁻¹), indigowoad leaf (551.0 µg kg⁻¹), rose flower (435.2 µg kg⁻¹) and eucommia bark (432.3 µg kg⁻¹). The proposed method could provide a useful basis for safety monitoring of herbs and risk management for PAHs in the health food industry.

  14. Analysis Method of 241Pu Radioactivity by Isotope Dilution-Extraction Liquid Scintillation Spectrometer

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>241Pu is the only pure β emitter with the maximum energy of 20.81 keV in plutonium isotopes of 238Pu, 239Pu, 240Pu and 242Pu, in which 241Pu is mostly specific radioactivity because its half-life is 14.29 a.

  15. Studies on accuracy of trichothecene multitoxin analysis using stable isotope dilution assays.

    Science.gov (United States)

    Asam, S; Rychlik, M

    2007-12-01

    Critical parameters in mycotoxin analysis were examined by using stable isotope-labelled tricho-thecenes. Sample weight was downsized to 1 g without loosing precision when sufficiently homogenized samples were taken for analysis. Complete extraction of trichothecenes could be achieved with a solvent mixture of acetonitrile+water (84+16; v+v) even without the use of stable isotope labelled standards. However, in particular for the analysis of deoxynivalenol the absolute amount of water in the solvent volume used for extraction appeared critical. Depending on the matrix a low water amount resulted in too low quantitative values when no stable isotope-labelled standards are applied to correct for incomplete extraction. In this case the used extraction volume had to be at least 10 ml for 1 g sample when acetonitrile + water (84+16; v+v) was used as extraction solvent.Losses during sample preparation using two different clean-up columns were not observed. On the contrary, matrix suppression in the ESI-interface of the LC-MS equipment was found to be a serious problem. Depending on the matrix, the latter effect resulted in considerably lower values for trichothecenes when no stable isotope-labelled standards were used to counterbalance this suppression.

  16. Establishment of an isotope dilution ultra-performance liquid chromatography tandem mass spectrometry method for simultaneous quantification of serum 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3%同位素稀释超高效液相色谱串联质谱法快速测定血清25-羟维生素D2和25-羟维生素D3临床方法的建立

    Institute of Scientific and Technical Information of China (English)

    禹松林; 韩建华; 张江涛; 张殿喜; 陈雨; 程倩; 苏薇; 邱玲

    2014-01-01

    3的方法,该法可应用于常规临床实验室评价维生素D含量.%Objective The aim of the paper is to providc a method for measuring serum 25-hydroxyvitamin D2 (25 (OH) D2) and 25-hydroxyvitamin D3 (25 (OH) D3) by isotope dilution ultraperformance liquid chromatography tandem mass spectrometry (ID-UPLC/MS/MS) and providing an assay that can be applied to the evaluation of the level of vitamin D in routine clinical laboratory.Methods We perforu the method establishment and evaluation in this stuely.Serum samples were mixed with 25 (OH) D2-D3 and 25 (OH) D3-D3 (internal standard) and treated with ZnSO4 solution and methanol to precipitate protein,and then extracted with hexane.After centrifugation,the supernatants were transferred and evaporated under a stream of nitrogen until dryness and reconstituted with mobile phase.Then the residuals were then analyzed by ID-UPLC/MS/MS system in the positive electro-spray ionization mode and multiple reaction monitor (MRM) mode,and the MRM transitions used for each analyte were:m/z 413.3→395.3 [25 (OH) D2],401.4→383.4 [25 (OH) D3],416.3→398.3 [25 (OH) D2-D3] and 404.4→386.4 [25(OH) D3-D3] ; the concentration of 25 (OH) D2 and 25 (OH) D3 were quantified by the isotope internal standard method and the standard curve was employed with a series of calibration.To estimate the precision of the method,four frozen serum pools and three quality control materials were repeatedly analyzed in three runs,and every pool was analyzed in triplicate.In addition,the recovery rates were analyzed with serum samples added with different levels of standard.500 healthy volunteers were recruited during May and August in 2013 in Beijing,and their 25(OH) D results were evaluated using the built method.Independent t test was used to analyze the results.Results Serum 25 (OH) D2 and 25 (OH) D3 measured by ID-UPLC/MS/ MS with MRM mode was separated well with few interferences.The retention time of 25 (OH) D2 and 25 (OH) D3 and internal

  17. Short communication: milk output in llamas (Lama glama) in relation to energy intake and water turnover measured by an isotope dilution technique.

    Science.gov (United States)

    Riek, A; Klinkert, A; Gerken, M; Hummel, J; Moors, E; Südekum, K-H

    2013-03-01

    Despite the fact that llamas have become increasingly popular as companion and farm animals in both Europe and North America, scientific knowledge on their nutrient requirements is scarce. Compared with other livestock species, relatively little is known especially about the nutrient and energy requirements for lactating llamas. Therefore, we aimed to measure milk output in llama dams using an isotope dilution technique and relate it to energy intakes at different stages of lactation. We also validated the dilution technique by measuring total water turnover (TWT) directly and comparing it with values estimated by the isotope dilution technique. Our study involved 5 lactating llama dams and their suckling young. Milk output and TWT were measured at 4 stages of lactation (wk 3, 10, 18, and 26 postpartum). The method involved the application of the stable hydrogen isotope deuterium ((2)H) to the lactating dam. Drinking water intake and TWT decreased significantly with lactation stage, whether estimated by the isotope dilution technique or calculated from drinking water and water ingested from feeds. In contrast, lactation stage had no effect on dry matter intake, metabolizable energy (ME) intake, or the milk water fraction (i.e., the ratio between milk water excreted and TWT). The ratios between TWT measured and TWT estimated (by isotope dilution) did not differ with lactation stage and were close to 100% in all measurement weeks, indicating that the D(2)O dilution technique estimated TWT with high accuracy and only small variations. Calculating the required ME intakes for lactation from milk output data and gross energy content of milk revealed that, with increasing lactation stage, ME requirements per day for lactation decreased but remained constant per kilogram of milk output. Total measured ME intakes at different stages of lactation were similar to calculated ME intakes from published recommendation models for llamas.

  18. A versatile method for simultaneous stable carbon isotope analysis of DNA and RNA nucleotides by liquid chromatography/isotope ratio mass spectrometry

    NARCIS (Netherlands)

    Moerdijk-Poortvliet, T.C.W.; Brasser, J.; de Ruiter, G.; Houtekamer, M.; Bolhuis, H.; Stal, L.J.; Boschker, H.T.S.

    2014-01-01

    RATIONALE Liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) is currently the most accurate and precise technique for the measurement of compound-specific stable carbon isotope ratios (13C/12C) in biological metabolites, at their natural abundance. However, until now this technique coul

  19. A versatile method for simultaneous stable carbon isotope analysis of DNA and RNA nucleotides by liquid chromatography/isotope ratio mass spectrometry

    NARCIS (Netherlands)

    Moerdijk-Poortvliet, T.C.W.; Brasser, J.; de Ruiter, G.; Houtekamer, M.; Bolhuis, H.; Stal, L.J.; Boschker, H.T.S.

    2014-01-01

    RATIONALELiquid chromatography/isotope ratio mass spectrometry (LC/IRMS) is currently the most accurate and precise technique for the measurement of compound-specific stable carbon isotope ratios (C-13/C-12) in biological metabolites, at their natural abundance. However, until now this technique cou

  20. An isotope dilution model for partitioning phenylalanine and tyrosine uptake by the mammary gland of lactating dairy cows.

    Science.gov (United States)

    Crompton, L A; France, J; Reynolds, C K; Mills, J A N; Hanigan, M D; Ellis, J L; Bannink, A; Bequette, B J; Dijkstra, J

    2014-10-21

    An isotope dilution model for partitioning phenylalanine and tyrosine uptake by the mammary gland of the lactating dairy cow is constructed and solved in the steady state. The model contains four intracellular and four extracellular pools and conservation of mass principles are applied to generate the fundamental equations describing the behaviour of the system. The experimental measurements required for model solution are milk secretion and plasma flow rate across the gland in combination with phenylalanine and tyrosine concentrations and plateau isotopic enrichments in arterial and venous plasma and free and protein bound milk during a constant infusion of [1-(13)C]phenylalanine and [2,3,5,6-(2)H]tyrosine tracer. If assumptions are made, model solution enables determination of steady state flows for phenylalanine and tyrosine inflow to the gland, outflow from it and bypass, and flows representing the synthesis and degradation of constitutive protein and phenylalanine hydroxylation. The model is effective in providing information about the fates of phenylalanine and tyrosine in the mammary gland and could be used as part of a more complex system describing amino acid metabolism in the whole ruminant.

  1. Vitamin A equivalency of beta-carotene in healthy adults: limitation of the extrinsic dual-isotope dilution technique to measure matrix effect.

    NARCIS (Netherlands)

    Loo-Bouwman, C.A. Van; West, C.E.; Breemen, R.B. van; Zhu, D.; Siebelink, E.; Versloot, P.; Hulshof, P.J.; Lieshout, Machteld van; Russel, F.G.M.; Schaafsma, G.; Naber, T.H.

    2009-01-01

    Data on the vitamin A equivalency of beta-carotene in food are inconsistent. We quantified the vitamin A equivalency (microg) of beta-carotene in two diets using the dual-isotope dilution technique and the oral-faecal balance technique. A diet-controlled, cross-over intervention study was conducted

  2. Vitamin A equivalency of ß-carotene in healthy adults: limitation of the extrinsic dual-isotope dilution technique to measure matrix effect

    NARCIS (Netherlands)

    Bouwman, C.A.; West, C.E.; Breemen, van R.B.; Zhu, D.; Siebelink, E.; Versloot, P.; Hulshof, P.J.M.; Lieshout, van M.; Russel, F.G.M.; Schaafsma, G.; Naber, T.H.J.

    2009-01-01

    Data on the vitamin A equivalency of ß-carotene in food are inconsistent. We quantified the vitamin A equivalency (¿g) of ß-carotene in two diets using the dual-isotope dilution technique and the oral¿faecal balance technique. A diet-controlled, cross-over intervention study was conducted in twenty-

  3. A novel quantification strategy of transferrin and albumin in human serum by species-unspecific isotope dilution laser ablation inductively coupled plasma mass spectrometry (ICP-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Liuxing, E-mail: fenglx@nim.ac.cn; Zhang, Dan; Wang, Jun; Shen, Dairui; Li, Hongmei

    2015-07-16

    Highlights: • Species-unspecific ID-PAGE-LA-ICP-MS was used to quantify Alb and Tf in human serum. • Addition methods of species-unspecific {sup 34}S spike were evaluated. • Isotope change conditions were investigated to reach satisfactory “isotope equilibration”. • Human serum CRM (ERM-DA470k/IFCC) was used to validate the new arrangements. • The developed method offers potential for accurate quantification of protein by ID-PAGE-LA-ICP-MS. - Abstract: Species-specific (SS) isotope dilution analysis with gel electrophoresis (GE)-laser ablation (LA)-ICP-MS is a promising technique for the quantification of particular metal-binding proteins in biological samples. However, unavailable isotopically enriched spike and metal losses in GE separation are main limitations for SS-isotope dilution PAGE-LA-ICP-MS. In this study, we report for the first time the absolute quantification of transferrin (Tf) and albumin (Alb) in human serum by non-denaturing (native) GE combined with species-unspecific isotope dilution mass spectrometry (IDMS). In order to achieve a homogeneous distribution of both protein and isotope-enriched spike (simulated isotope equilibration), immersing the protein strips with {sup 34}S spike solution after gel electrophoresis was demonstrated to be an effective way of spike addition. Furthermore, effects of immersion time and {sup 34}S spike concentration were investigated to obtain optimal conditions of the post-electrophoresis isotope dilution method. The relative mass of spike and ablated sample (m{sub sp}/m{sub sam}) in IDMS equation was calculated by standard Tf and Alb proteins, which could be applied to the quantification of Tf and Alb in ERM-DA470k/IFCC for method confirmation. The results were in agreement with the certified value with good precision and small uncertainty (1.5–3%). In this method, species-specific spike protein is not necessary and the integrity of the heteroatom-protein could be maintained in sample preparation

  4. Speciated isotope dilution analysis of Cr(III) and Cr(VI) in water by ICP-DRC-MS.

    Science.gov (United States)

    Ma, H-L; Tanner, P A

    2008-10-19

    An isotope dilution method has been developed for the speciation analysis of chromium in natural waters which accounts for species interconversions without the requirement of a separation instrument connected to the mass spectrometer. The method involves (i) in-situ spiking of the sample with isotopically enriched chromium species; (ii) separation of chromium species by precipitation with iron hydroxide; (iii) careful measurement of isotope ratios using an inductively coupled plasma mass spectrometer (ICP-MS) with a dynamic reaction cell (DRC) to remove isobaric polyatomic interferences. The method detection limits are 0.4 microg L(-1) for Cr(III) and 0.04 microg L(-1) for Cr(VI). The method is demonstrated for the speciation of Cr(III) and Cr(VI) in local nullah and synthetically spiked water samples. The percentage of conversion from Cr(III) to Cr(VI) increased from 5.9% to 9.3% with increase of the concentration of Cr(VI) and Cr(III) from 1 to 100 microg L(-1), while the reverse conversion from Cr(VI) to Cr(III) was observed within a range between 0.9% and 1.9%. The equilibrium constant for the conversion was found to be independent of the initial concentrations of Cr(III) and Cr(VI) and in the range of 1.0 (at pH 3) to 1.8 (at pH 10). The precision of the method is better than that of the DPC method for Cr(VI) analysis, with the added bonuses of freedom from interferences and simultaneous Cr(III) determination.

  5. Reduction of matrix effects in liquid chromatography-electrospray ionization-mass spectrometry by dilution of the sample extracts: how much dilution is needed?

    Science.gov (United States)

    Stahnke, Helen; Kittlaus, Stefan; Kempe, Günther; Alder, Lutz

    2012-02-01

    In this study, the relationship between matrix concentration and suppression of electrospray ionization (matrix effects) was investigated. Ion suppression of pesticides present in QuEChERS extracts was used as an example. Residue-free extracts of four different commodities, avocado, black tea, orange, and rocket (arugula), were fortified with 39 pesticides each. For many of the resulting 156 pesticide/matrix combinations, considerable matrix effects were observed if the coextracted matrix of 8 mg of equivalent sample (in the case of tea: 1.6 mg) was injected with the undiluted extracts. The reduction of these matrix effects was measured at 10 levels of dilution up to 1000-fold. The results obtained indicate a linear correlation between matrix effects and the logarithm of matrix concentration (or dilution factor) until the zero-effect level of further dilution was reached. Using the logarithmic equations, it could be shown that a dilution of extracts by a factor of 25-40 reduces ion suppression to less than 20% if the initial suppression is ≤80%. For stronger matrix effects or complete elimination of suppression, higher dilution factors were needed. The observed correlation was independent from the two instrument platforms used, but the degree of matrix effects differed slightly between the two mass spectrometers in this study.

  6. Ionic liquids as novel stationary phases in gas liquid chromatography: inverse or normal isotope effect?

    Science.gov (United States)

    Schmarr, Hans-Georg; Slabizki, Petra; Müntnich, Sabrina; Metzger, Carmen; Gracia-Moreno, Elisa

    2012-12-28

    The separation of deuterated and non-deuterated compounds in gas liquid partitioning chromatography (GLC) on silicone type stationary phase usually results in the inverse isotope effect. With ionic liquids (ILs) as stationary phase, however, this may show a totally different nature. The inverse isotope effect, in which heavier (deuterated) isotopic compounds (isotopologues) elute earlier, is to be expected when van der Waals (London) dispersion forces play a dominant role in the solute-stationary phase interaction. Such (apolar) interactions seem to play only a minor role when ILs are the stationary phases, leading to only a marginal inverse isotope effect, e.g. for the separation of 2,4,6-trichloroanisole and its [(2)H(5)]-isotopologue on 1,12-di(tripropylphosphonium) dodecane bis(trifluoromethansulfonyl) amide (commercialized as SLB-IL59, Supelco). Indeed, with the most polar stationary phase available (commercialized as SLB-IL111; Supelco), this separation showed a normal isotope effect. Further examples are presented and the nature of the isotope effect observed is discussed.

  7. Characterising the exchangeability of phenanthrene associated with naturally occurring soil colloids using an isotopic dilution technique.

    Science.gov (United States)

    Tavakkoli, Ehsan; Juhasz, Albert; Donner, Erica; Lombi, Enzo

    2015-04-01

    The association of polycyclic aromatic hydrocarbons (PAHs) with inorganic and organic colloids is an important factor influencing their bioavailability, mobility and degradation in the environment. Despite this, our understanding of the exchangeability and potential bioavailability of PAHs associated with colloids is limited. The objective of this study was to use phenanthrene as a model PAH compound and develop a technique using (14)C phenanthrene to quantify the isotopically exchangeable and non-exchangeable forms of phenanthrene in filtered soil water or sodium tetraborate extracts. The study was also designed to investigate the exchangeability of colloidal phenanthrene as a function of particle size. Our findings suggest that the exchangeability of phenanthrene in sodium tetraborate is controlled by both inorganic and organic colloids, while in aqueous solutions inorganic colloids play the dominant role (even though coating of these by organic matter cannot be excluded). Filter pore size did not have a significant effect on phenanthrene exchangeability. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Simultaneous measurement of tabun, sarin, soman, cyclosarin, VR, VX, and VM adducts to tyrosine in blood products by isotope dilution UHPLC-MS/MS.

    Science.gov (United States)

    Crow, Brian S; Pantazides, Brooke G; Quiñones-González, Jennifer; Garton, Joshua W; Carter, Melissa D; Perez, Jonas W; Watson, Caroline M; Tomcik, Dennis J; Crenshaw, Michael D; Brewer, Bobby N; Riches, James R; Stubbs, Sarah J; Read, Robert W; Evans, Ronald A; Thomas, Jerry D; Blake, Thomas A; Johnson, Rudolph C

    2014-10-21

    This work describes a new specific, sensitive, and rapid stable isotope dilution method for the simultaneous detection of the organophosphorus nerve agents (OPNAs) tabun (GA), sarin (GB), soman (GD), cyclosarin (GF), VR, VX, and VM adducts to tyrosine (Tyr). Serum, plasma, and lysed whole blood samples (50 μL) were prepared by protein precipitation followed by digestion with Pronase. Specific Tyr adducts were isolated from the digest by a single solid phase extraction (SPE) step, and the analytes were separated by reversed-phase ultra high performance liquid chromatography (UHPLC) gradient elution in less than 2 min. Detection was performed on a triple quadrupole tandem mass spectrometer using time-triggered selected reaction monitoring (SRM) in positive electrospray ionization (ESI) mode. The calibration range was characterized from 0.100-50.0 ng/mL for GB- and VR-Tyr and 0.250-50.0 ng/mL for GA-, GD-, GF-, and VX/VM-Tyr (R(2) ≥ 0.995). Inter- and intra-assay precision had coefficients of variation of ≤17 and ≤10%, respectively, and the measured concentration accuracies of spiked samples were within 15% of the targeted value for multiple spiking levels. The limit of detection was calculated to be 0.097, 0.027, 0.018, 0.074, 0.023, and 0.083 ng/mL for GA-, GB-, GD-, GF-, VR-, and VX/VM-Tyr, respectively. A convenience set of 96 serum samples with no known nerve agent exposure was screened and revealed no baseline values or potential interferences. This method provides a simple and highly specific diagnostic tool that may extend the time postevent that a confirmation of nerve agent exposure can be made with confidence.

  9. Measurement of O(6)-alkylguanine-DNA alkyltransferase activity in tumour cells using stable isotope dilution HPLC-ESI-MS/MS.

    Science.gov (United States)

    Sun, Guohui; Zhao, Lijiao; Fan, Tengjiao; Ren, Ting; Zhong, Rugang

    2016-10-15

    The repair of DNA mediated by O(6)-alkylguanine-DNA alkyltransferase (AGT) provides protection against DNA damage from endogenous or exogenous alkylation of the O(6) position of guanine. However, this repair acts as a double-edged sword in cancer treatment, as it not only protects normal cells from chemotherapy-associated toxicities, but also results in cancer cell resistance to guanine O(6)-alkylating antitumour agents. Thus, AGT plays an important role in predicting the individual susceptibility to guanine O(6)-alkylating carcinogens and chemotherapies. Accordingly, it is necessary to establish a quantitative method for determining AGT activity with high accuracy, sensitivity and practicality. Here, we describe a novel nonradioactive method for measuring AGT activity using stable isotope dilution high-performance liquid chromatography electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). This method is based on the irreversibility of the removal of the O(6)-alkyl group from guanine by AGT and on the high affinity of O(6)-benzylguanine (O(6)-BG) as an AGT substrate. HPLC-ESI-MS/MS was used to measure the AGT activities in cell protein extracts from eight tumour lines, demonstrating that AGT activity was quite variable among different cell lines, ranging from nondetectable to 1021 fmol/mg protein. The experiments performed in intact tumour cells yielded similar results but exhibited slightly higher activities than those observed in cell protein extracts. The accuracy of this method was confirmed by an examination of AGT expression levels using western blotting analysis. To our knowledge, this method is the first mass spectrometry-based AGT activity assay, and will likely provide assistance in the screening of cancer risk or the application of chemotherapies.

  10. Elevated urinary levels of carcinogenic N-nitrosamines in patients with urinary tract infections measured by isotope dilution online SPE LC–MS/MS

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Chiung-Wen [Department of Public Health, Chung Shan Medical University, Taichung 402, Taiwan (China); Shih, Ying-Ming [Department of Public Health, Chung Shan Medical University, Taichung 402, Taiwan (China); Division of Chest Medicine, Department of Internal Medicine, Changhua Christian Hospital, Changhua 500, Taiwan (China); Liu, Hung-Hsin [Department of Occupational Safety and Health, Chung Shan Medical University, Taichung 402, Taiwan (China); Chiang, Yi-Chen [Department of Public Health, Chung Shan Medical University, Taichung 402, Taiwan (China); School of Public Health, Xiamen University, Xiamen 361102, Fujian (China); Chen, Chih-Ming [Department of Occupational Safety and Health, Chung Shan Medical University, Taichung 402, Taiwan (China); Chao, Mu-Rong, E-mail: chaomurong@gmail.com [Department of Occupational Safety and Health, Chung Shan Medical University, Taichung 402, Taiwan (China); Department of Occupational Medicine, Chung Shan Medical University Hospital, Taichung 402, Taiwan (China)

    2016-06-05

    Highlights: • Nine N-nitrosamines in urine were quantified by LC–MS/MS. • N-nitrosodiphenylamine was firstly identified in human urine. • UTI patients had much higher N-nitrosamines concentrations than healthy subjects. • N-nitrosamines were dramatically decreased after antibiotic treatment. • NDMA was correlated with the pH, WBC esterase activity or nitrite in UTI patients. - Abstract: N-nitrosamines (NAms) are well-documented for their carcinogenic potential. Human exposure to NAms may arise from the daily environment and endogenous formation via the reaction of secondary amines with nitrites or from bacteria infection. We describe the use of isotope dilution online solid-phase extraction (SPE) LC–MS/MS to quantify nine NAms in human urine. This method was validated and further applied to healthy subjects and patients with urinary tract infection (UTI). N-nitrosodimethylamine (NDMA), N-nitrosomethylethylamine (NMEA), N-nitrosopyrrolidine (NPYR) and N-nitrosomorpholine (NMOR) were analyzed with an APCI source, while N-nitrosodiethylamine (NDEA), N-nitrosopiperidine (NPIP), N-nitrosodi-n-propylamine (NDPA), N-nitrosodibutylamine (NDBA) and N-nitrosodiphenylamine (NDPhA) were quantified with an ESI source, due to their effect on the sensitivity and chromatography. NDMA was the most abundant N-nitrosamine, while NDPhA was firstly identified in human. UTI patients had three to twelve-fold higher concentrations for NDMA, NPIP, NDEA, NMOR and NDBA in urine than healthy subjects, and the NAms were significantly decreased after antibiotics treatment. NDMA concentrations were also significantly correlated with the pH value, leukocyte esterase activity or nitrite in urines of UTI patients. Our findings by online SPE LC–MS/MS method evidenced that UTI patients experienced various NAms exposures, especially the potent carcinogen NDMA, which was likely induced by bacteria infection.

  11. Simultaneous analysis of oxybutynin and its active metabolite N-desethyl oxybutynin in human plasma by stable isotope dilution LC-MS/MS to support a bioequivalence study.

    Science.gov (United States)

    Sharma, Primal; Patel, Daxesh P; Sanyal, Mallika; Berawala, Hiren; Guttikar, Swati; Shrivastav, Pranav S

    2013-10-01

    An isotope dilution high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed for the simultaneous determination of oxybutynin and its pharmacologically active metabolite N-desethyl oxybutynin in human plasma. Extraction of oxybutynin, its metabolite and their deuterated analogs as internal standards (ISs) from 300 μL human plasma was carried out by liquid-liquid extraction with methyl tert-butyl ether-ethyl acetate solvent mixture. Chromatographic separation of analytes was performed on Cosmosil C18 (150 mm × 4.6 mm, 5 μm) column under isocratic conditions with acetonitrile-1.0mM ammonium acetate (90:10, v/v) as the mobile phase. Six endogenous plasma phospholipids (496.3/184.0, 524.3/184.0, 758.5/184.0, 786.5/184.0, 806.5/184.0 and 810.5/184.0) were monitored to determine the extraction efficiency under different extraction conditions. The precursor→product ion transition for both the analytes and ISs were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring and positive ionization mode. The method was validated over a concentration range of 0.050-10.0 ng/mL for oxybutynin and 0.500-100 ng/mL for N-desethyl oxybutynin. The mean extraction recovery for analytes (80.4%) and ISs (76.9%) was consistent across five QC levels. Bench top, wet and dry extract, freeze-thaw and long term stability was evaluated for both the analytes. The method was applied to support a bioequivalence study of 5mg tablet formulation in 74 healthy Indian subjects. Assay reproducibility was demonstrated by reanalysis of 344 incurred samples.

  12. Vitamin A equivalency and apparent absorption of beta-carotene in ileostomy subjects using a dual-isotope dilution technique.

    Science.gov (United States)

    Van Loo-Bouwman, Carolien A; Naber, Ton H J; van Breemen, Richard B; Zhu, Dongwei; Dicke, Heleen; Siebelink, Els; Hulshof, Paul J M; Russel, Frans G M; Schaafsma, Gertjan; West, Clive E

    2010-06-01

    The objective was to quantify the vitamin A equivalency of beta-carotene in two diets using a dual-isotope dilution technique and the apparent beta-carotene absorption as measured by the oral-faecal balance technique. Seventeen healthy adults with an ileostomy completed the 4-week diet-controlled, cross-over intervention study. Each subject followed both diets for 2 weeks: a diet containing vegetables low in beta-carotene content with supplemental beta-carotene in salad dressing oil ('oil diet'; mean beta-carotene intake 3.1 mg/d) and a diet containing vegetables and fruits high in beta-carotene content ('mixed diet'; mean beta-carotene intake 7.6 mg/d). Daily each subject consumed a mean of 190 microg [13C10]beta-carotene and 195 microg [13C10]retinyl palmitate in oil capsules. The vitamin A equivalency of beta-carotene was calculated as the dose-corrected ratio of [13C5]retinol to [13C10]retinol in serum. Apparent absorption of beta-carotene was determined with oral-faecal balance. Isotopic data quantified a vitamin A equivalency of [13C10]beta-carotene in oil of 3.6:1 (95 % CI 2.8, 4.6) regardless of dietary matrices differences. The apparent absorption of (labelled and dietary) beta-carotene from the 'oil diet' (30 %) was 1.9-fold higher than from the 'mixed diet' (16 %). This extrinsic labelling technique can measure precisely the vitamin A equivalency of beta-carotene in oil capsules, but it does not represent the effect of different dietary matrices.

  13. Carbon Stable Isotope Analysis of Methylmercury Toxin in Biological Materials by Gas Chromatography Isotope Ratio Mass Spectrometry.

    Science.gov (United States)

    Masbou, Jeremy; Point, David; Guillou, Gaël; Sonke, Jeroen E; Lebreton, Benoit; Richard, Pierre

    2015-12-01

    A critical component of the biogeochemical cycle of mercury (Hg) is the transformation of inorganic Hg to neurotoxic monomethylmercury (CH3Hg). Humans are exposed to CH3Hg by consuming marine fish, yet the origin of CH3Hg in fish is a topic of debate. The carbon stable isotopic composition (δ(13)C) embedded in the methyl group of CH3Hg remains unexplored. This new isotopic information at the molecular level is thought to represent a new proxy to trace the carbon source at the origin of CH3Hg. Here, we present a compound-specific stable isotope analysis (CSIA) technique for the determination of the δ(13)C value of CH3Hg in biological samples by gas chromatography combustion isotope ratio mass spectrometry analysis (GC-C-IRMS). The method consists first of calibrating a CH3Hg standard solution for δ(13)C CSIA. This was achieved by comparing three independent approaches consisting of the derivatization and halogenation of the CH3Hg standard solution. The determination of δ(13)C(CH3Hg) values on natural biological samples was performed by combining a CH3Hg selective extraction, purification, and halogenation followed by GC-C-IRMS analysis. Reference δ(13)C values were established for a tuna fish certified material (ERM-CE464) originating from the Adriatic Sea (δ(13)C(CH3Hg) = -22.1 ± 1.5‰, ± 2 SD). This value is similar to the δ(13)C value of marine algal-derived particulate organic carbon (δ(13)CPOC = -21‰).

  14. A liquid chromatography - mass spectrometry method to measure ¹³C-isotope enrichment for DNA stable-isotope probing.

    Science.gov (United States)

    Auclair, Julie; Lépine, François; Villemur, Richard

    2012-03-01

    DNA stable-isotope probing (DNA-SIP) is a cultivation-independent technique that makes it possible to associate metabolic function and taxonomic identity in a wide range of terrestrial and aquatic environments. In DNA-SIP, DNA is labeled via the assimilation of a labeled growth substrate that is subsequently used to identify microorganisms involved in assimilation of the substrate. However, the labeling time has to be sufficient to obtain labeled DNA but not so long such that cross-feeding of ¹³C-labeled metabolites from the primary consumers to nontarget species can occur. Confirmation that the DNA is isotopically labeled in DNA-SIP assays can be achieved using an isotope ratio mass spectrometer. In this study, we describe the development of a method using liquid chromatography (HPLC) coupled to a quadrupole mass spectrometer (QMS) to measure the ¹³C enrichment of thymine incorporated into DNA in Escherichia coli cultures fed with [¹³C]acetate. The method involved the hydrolysis of DNA extracted from the cultures that released the nucleotides, followed by the separation of the thymine by HPLC on a reverse-phase C₈ column in isocratic elution mode and the detection and quantification of ¹³C-labeled thymine by QMS. To mimic a DNA-SIP assay, a DNA mixture was made using ¹³C-labeled E. coli DNA with DNA extracted from five bacterial species. The HPLC-MS method was able to measure the correct proportion of ¹³C-DNA in the mix. This method can then be used as an alternative to the use of isotope ratio mass spectrometry in DNA-SIP assays.

  15. Application of isotope dilution analysis for the evaluation of extraction conditions in the determination of total selenium and selenomethionine in yeast-based nutritional supplements.

    Science.gov (United States)

    Hinojosa Reyes, L; Marchante-Gayón, J M; García Alonso, J I; Sanz-Medel, A

    2006-03-08

    Isotope dilution analysis (IDA) has been used to quantify total selenium, total solubilized selenium, and the selenomethionine (SeMet) amount in yeast and yeast-based nutritional supplements after acid microwave digestion and different enzymatic extraction procedures. For this purpose, both a (77)Se-enriched SeMet spike, previously synthesized and characterized in our laboratory, and a (77)Se(VI) spike were used. In the analysis of the nutritional supplements, the SeMet spike was added to the sample and extracted under different conditions, and the (78)Se/(77)Se and (80)Se/(77)Se isotope ratios were measured as peak area ratios after high-performance liquid chromatography (HPLC) separation and inductively coupled plasma mass spectrometry (ICP-MS) detection. The formation of SeH(+) and mass discrimination were corrected using a natural SeMet standard injected every three samples. Similarly, total solubilized selenium was measured in the extracts after enzymatic hydrolysis using the (77)Se-enriched SeMet as a spike by direct nebulization without a chromatographic separation. To establish a mass balance, total selenium was also determined by IDA-ICP-MS on the yeast tablets after microwave digestion using (77)Se(VI) as a spike. Results showed that all enzymatic procedures tested were able to solubilize total selenium quantitatively from the solid. However, the recovery for the species SeMet, the major selenium compound detected, was seriously affected by the enzymatic procedure employed and also by the matrix composition of the supplement evaluated. For the yeast sample, SeMet recovery increased from 68 to 76% by the combined use of driselase and protease. For the nutritional supplements, the two most effective procedures appeared to be protease and driselase/protease, with a SeMet recovery ranging from 49 to 63%, depending upon the supplement evaluated. In the case of in vitro gastrointestinal enzymolysis, the results obtained showed 26-37% SeMet recovery, while the

  16. Evaluation of matrix effect in isotope dilution mass spectrometry based on quantitative analysis of chloramphenicol residues in milk powder

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xiu Qin; Yang, Zong; Zhang, Qing He, E-mail: qhzhang204@gmail.com; Li, Hong Mei

    2014-01-07

    Graphical abstract: -- Highlights: •We develop a strategy to evaluate matrix effect and its impact on the IDMS results. •Matrix effect and IDMS correction factor from different conditions are evaluated. •Ion suppression effect is observed in LLE and HLB pre-treated sample solutions. •Ion enhancement effect is found in MCX pre-treated sample solution. •IDMS correction factor in HLB and MCX solutions in three instruments is close to 1 -- Abstract: In the present study, we developed a comprehensive strategy to evaluate matrix effect (ME) and its impact on the results of isotope dilution mass spectrometry (IDMS) in analysis of chloramphenicol (CAP) residues in milk powder. Stable isotope-labeled internal standards do not always compensate ME, which brings the variation of the ratio (the peak area of analyte/the peak area of isotope). In our investigation, impact factors of this variation were studied in the extraction solution of milk powder using three mass spectrometers coupled with different ion source designs, and deuterium-labeled chloramphenicol (D5-CAP) was used as the internal standard. ME from mobile phases, sample solvents, pre-treatment methods, sample origins and instruments was evaluated, and its impact on the results of IDMS was assessed using the IDMS correction factor (θ). Our data showed that the impact of ME of mobile phase on the correction factor was significantly greater than that of sample solvent. Significant ion suppression and enhancement effects were observed in different pre-treated sample solutions. The IDMS correction factor in liquid–liquid extraction (LLE) and molecular imprinted polymer (MIP) extract with different instruments was greater or less 1.0, and the IDMS correction factor in hydrophilic lipophilic balance (HLB) and mix-mode cation exchange (MCX) extract with different instruments was all close to 1.0. To the instrument coupled with different ion source design, the impact of ME on IDMS quantitative results was

  17. Application of isotope dilution method for measuring bioavailability of organic contaminants sorbed to dissolved organic matter (DOM)

    Energy Technology Data Exchange (ETDEWEB)

    Delgado-Moreno, Laura, E-mail: laura.delgado@eez.csic.es; Wu, Laosheng; Gan, Jay

    2015-08-15

    Natural waters such as surface water and sediment porewater invariably contain dissolved organic matter (DOM). Association of strongly hydrophobic contaminants (HOCs) with DOM leads to decreased toxicity and bioavailability, but bioavailability of DOM-sorbed HOCs is difficult to measure. Current methods to estimate bioavailability of HOCs in water are based on only the freely dissolved concentration (C{sub free}). The ignorance of the exchangeable fraction of HOCs sorbed on DOM may result in an underestimation of the toxicity potential of HOCs to aquatic organisms. Here we explore the applicability of an isotope dilution method (IDM) to measuring the desorption fraction of DOM-sorbed pyrene and bifenthrin and determining their exchangeable pool (E) as an approximation of bioavailability. E values, expressed as percentage of the total concentration, ranged between 0.80 and 0.92% for pyrene and 0.74 and 0.85% for bifenthrin, depending primarily on the amount of chemical in the freely dissolved form. However, between 34 and 78% of the DOM-sorbed pyrene was exchangeable. This fraction ranged between 23% and 82% for bifenthrin. The ability of IDM to predict bioavailability was further shown from a significant relationship (r{sup 2} > 0.72, P < 0.0001) between E and bioaccumulation into Daphnia magna. Therefore, IDM may be used to improve the bioavailability measurement and risk assessment of HOCs in aquatic systems.

  18. Online determination of copper in aluminum alloy by microchip solvent extraction using isotope dilution ICP-MS method.

    Science.gov (United States)

    Kagawa, Tsuyoshi; Ohno, Masashi; Seki, Tatsuya; Chikama, Katsumi

    2009-09-15

    Isotope dilution mass spectroscopy (IDMS)/ICP-MS combined with microchip solvent extraction was successfully applied for the online determination of copper in an aluminum alloy. The microchip solvent extraction was developed for the separation of Cu from major element, and optimal pH range was wider than that of the batchwise extraction method. The dimensions of the microchip were 30 mm x 70 mm and that of micro-channel on the microchip was 180 microm wide and 40 microm deep. The copper complex with 8-hydroxyquinoline was extracted into o-xylene at pH 5.5 and back extracted with 0.1 mol l(-1) nitric acid at flow rate of 20 microl min(-1). The total extraction efficiency (water/organic solvent/nitric acid) was around 40%. IDMS/ICP-MS was coupled with solvent extraction for precise determination of Cu. The extraction and back-extraction on the microchip took about 1s and the total measurement time for the IDMS/ICP-MS was about 40s/sample. The blank value of this method was 0.1 ng g(-1). The proposed method was used for the determination of Cu in Al standard materials (JSAC 0121-C, The Japan Society for Analytical Chemistry and 7074 Al alloy, Nippon Light Metal Co. Ltd.). The obtained analytical results are in good agreement with the certified values.

  19. Content of the Alternaria mycotoxin tenuazonic acid in food commodities determined by a stable isotope dilution assay.

    Science.gov (United States)

    Asam, Stefan; Lichtenegger, Martina; Liu, Yang; Rychlik, Michael

    2012-02-01

    The Alternaria mycotoxin tenuazonic acid (TA) was quantified in fruit juices (n = 50), cereals (n = 12) and spices (n = 38) using a recently developed stable isotope dilution assay (SIDA). [(13) C6,(15) N]-TA was used as the internal standard. Method validation revealed low limits of detection (LODs) of 0.15 μg/kg (fruit juices), 1.0 μg/kg (cereals) and 17 μg/kg (spices). The respective limits of quantitation were about three times higher. Recovery was about 100% for all matrices. The precision (relative standard deviation of replicate analyses of naturally contaminated samples) was 4.2% (grape juice; 1.7 μg/kg), 3.5% (whole wheat flour; 36 μg/kg) and 0.9% (curry powder; 215 μg/kg). The median content of TA in the analyzed samples was 1.8 μg/kg (fruit juices), 16 μg/kg (cereals) and 500 μg/kg (spices). Positive samples amounted to 86% (fruit juices), 92% (cereals) and 87% (spices).

  20. Fixation of metals in soil constituents and potential remobilization by hyperaccumulating and non-hyperaccumulating plants: results from an isotopic dilution study.

    Science.gov (United States)

    Hammer, Daniel; Keller, Catherine; McLaughlin, Michael J; Hamon, Rebecca E

    2006-10-01

    In this study isotopic dilution methods were used to investigate the hypothesis that access to metals associated with specific chemical components in the soil that are not available to non-accumulator species could be involved in hyperaccumulation. The hyperaccumulator Thlaspi caerulescens and a non-accumulator species, Brassica napus, were grown in Cd and Zn enriched soil components calcite, goethite, charcoal and cryptomelane. The metal enriched components were aged to allow transformation of a proportion of added metals to non-labile forms. Results from the isotopic dilution L value method showed that despite taking up more metals, T. caerulescens accessed the same pool of metals as B. napus. Hence differential access to different solid-phase pools of metals appears to be an unlikely mechanism underlying metal hyperaccumulation. For all components except charcoal, L values for Cd and Zn were greater than the corresponding E values suggesting that E values may tend to underestimate the bioavailable fraction of metals in soils.

  1. Tritium isotope effect in high-performance liquid chromatography of eicosanoids

    Energy Technology Data Exchange (ETDEWEB)

    Do, U.H.; Lo, S.-L.; Iles, J.; Rosenberger, T.; Tam, P.; Hong, Y.; Ahern, D. [DuPont, NEN Products, Boston (United States). Lipids Group

    1994-07-01

    A significant difference in retention time between unlabeled and the corresponding multi-tritium-labeled eicosanoid has been observed in the high performance liquid chromatography (HPLC) analysis of 11 eicosanoids. Variations in retention time range from 3-7%, depending on the separation conditions as well as the number and position of the tritium substitution. Multi-tritium-labeled eicosanoids were eluted earlier than the corresponding unlabeled eicosanoid in reversed phase HPLC, whereas no isotope effect was seen with {sup 14}C- and {sup 3}H{sub 2}-eicosanoids. Considerations must be given to this tritium isotope effect whenever both multi-tritium-labeled and unlabeled eicosanoids are used for HPLC cochromatography or recovery studies. (author).

  2. Protein Stable Isotope Fingerprinting (P-SIF): Multidimensional Protein Chromatography Coupled to Stable Isotope-Ratio Mass Spectrometry

    Science.gov (United States)

    Pearson, A.; Bovee, R. J.; Mohr, W.; Tang, T.

    2012-12-01

    As metagenomics increases our insight into microbial community diversity and metabolic potential, new approaches are required to determine the biogeochemical expression of this potential within ecosystems. Because stable isotopic analysis of the major bioactive elements (C, N) has been used historically to map flows of substrates and energy among macroscopic food webs, similar principles may apply to microbes. To address this challenge, we have developed a new analytical approach called Protein Stable Isotope Fingerprinting (P-SIF). P-SIF generates natural stable isotopic fingerprints of microbial individual or community proteomes. The main advantage of P-SIF is the potential to bridge the gap between diversity and function, thereby providing a window into the "black box" of environmental microbiology and helping to decipher the roles of uncultivated species. Our method implements a three-way, orthogonal scheme to separate mixtures of whole proteins into subfractions dominated by single or closely-related proteins. Protein extracts first are isoelectrically focused in a gel-free technique that yields 12 fractions separated over a gradient of pH 3-10. Each fraction then is separated by size-exclusion chromatography into 20 pools, ranging from >100kD to ~10kD. Finally, each of these pools is subjected to HPLC and collected in 40 time-slices based on protein hydrophobicity. Theoretical calculation reveals that the true chromatographic resolution of the total scheme is 5000, somewhat less than the 9600 resulting fractions. High-yielding fractions are subjected to δ13C analysis by spooling-wire microcombustion irMS (SWiM-irMS) optimized for samples containing 1-5 nmol carbon. Here we will present the method, results for a variety of pure cultures, and preliminary data for a sample of mixed environmental proteins. The data show the promise of this method for unraveling the metabolic complexity hidden within microbial communities.

  3. A method for the routine determination of methylmercury in marine tissue by GC isotope dilution-ICP-MS.

    Science.gov (United States)

    Valdersnes, Stig; Maage, Amund; Fliegel, Daniel; Julshamn, Kåre

    2012-01-01

    Currently, there is no legal limit for methyl mercury (MeHg) in food; thus, no standardized method for the determination of MeHg in seafood exists within the European jurisdiction. In anticipation of a future legislative limit an inductively coupled plasma isotope dilution mass spectrometry (GC-ICP-ID-MS) method was developed in collaboration with the European Standardization Organization (CEN). The method comprises spiking the tissue sample with Me201Hg, followed by decomposition with tetramethylammonium hydroxide, pH adjustment and derivatization with sodium tetraethylborate, and finally organic extraction of the derivatized MeHg in a hexane phase. Subsequently, the sample is analyzed via GC-ICP-MS and the result calculated using the ID equation. The working range of the method was 0.0005-1.321 mg/kg MeHg in marine tissue, with an internal reproducibility (RSD) of 12-1%. The method was validated based on statistical measures, such as the z-scores, using the commercially available reference materials from National Institute of Standards and Technology Standard Reference Material (NIST SRM) 1566b, NIST SRM 2977 and National Research Council of Canada (NRCC) TORT 2, NRCC, DORM 3, NRCC DOLT 4, and European Reference Material (ERM) CE 464. Z-scores for all standard reference materials, except for NIST SRM 1566b, were better than 11.51. The wide range of marine tissues used during the validation ensures that the method will be applicable for measuring of MeHg in seafood matrixes of all kinds.

  4. Folate bioavailability from foods rich in folates assessed in a short term human study using stable isotope dilution assays.

    Science.gov (United States)

    Mönch, Sabine; Netzel, Michael; Netzel, Gabriele; Ott, Undine; Frank, Thomas; Rychlik, Michael

    2015-01-01

    Different sources of folate may have different bioavailability and hence may impact the standard definition of folate equivalents. In order to examine this, a short term human study was undertaken to evaluate the relative native folate bioavailabilities from spinach, Camembert cheese and wheat germs compared to pteroylmonoglutamic acid as the reference dose. The study had a single-centre, randomised, four-treatment, four-period, four-sequence, cross-over design, i.e. the four (food) items to be tested (referred to as treatments) were administered in sequences according to the Latin square, so that each experimental treatment occurred only once within each sequence and once within each study period. Each of the 24 subjects received the four experimental items separated by a 14-day equilibrium phase and received a pteroylmonoglutamic acid supplement for 14 days before the first testing and between the testings for saturation of body pools. Folates in test foods, plasma and urine samples were determined by stable isotope dilution assays, and in urine and plasma, the concentrations of 5-methyltetrahydrofolate were evaluated. Standard non-compartmental methods were applied to determine the biokinetic parameters C(max), t(max) and AUC from baseline corrected 5-methyltetrahydrofolate concentrations within the interval from 0 to 12 hours. The variability of AUC and C(max) was moderate for spinach and oral solution of pteroylmonoglutamic acid but high for Camembert cheese and very high for wheat germs. The median t(max) was lowest for spinach, though t(max) showed a high variability among all treatments. When comparing the ratio estimates of AUC and C(max) for the different test foods, highest bioavailability was found for spinach followed by that for wheat germs and Camembert cheese. The results underline the dependence of folate bioavailability on the type of food ingested. Therefore, the general assumption of 50% bioavailability as the rationale behind the definition of

  5. Advancement and application of gas chromatography isotope ratio mass spectrometry techniques for atmospheric trace gas analysis

    Science.gov (United States)

    Giebel, Brian M.

    2011-12-01

    The use of gas chromatography isotope ratio mass spectrometry (GC-IRMS) for compound specific stable isotope analysis is an underutilized technique because of the complexity of the instrumentation and high analytical costs. However stable isotopic data, when coupled with concentration measurements, can provide additional information on a compounds production, transformation, loss, and cycling within the biosphere and atmosphere. A GC-IRMS system was developed to accurately and precisely measure delta13C values for numerous oxygenated volatile organic compounds having natural and anthropogenic sources. The OVOCs include methanol, ethanol, acetone, methyl ethyl ketone, 2-pentanone, and 3-pentanone. Guided by the requirements for analysis of trace components in air, the GC-IRMS system was developed with the goals of increasing sensitivity, reducing dead-volume and peak band broadening, optimizing combustion and water removal, and decreasing the split ratio to the IRMS. The technique relied on a two-stage preconcentration system, a low-volume capillary reactor and water trap, and a balanced reference gas delivery system. Measurements were performed on samples collected from two distinct sources (i.e. biogenic and vehicle emissions) and ambient air collected from downtown Miami and Everglades National Park. However, the instrumentation and the method have the capability to analyze a variety of source and ambient samples. The measured isotopic signatures that were obtained from source and ambient samples provide a new isotopic constraint for atmospheric chemists and can serve as a new way to evaluate their models and budgets for many OVOCs. In almost all cases, OVOCs emitted from fuel combustion were enriched in 13C when compared to the natural emissions of plants. This was particularly true for ethanol gas emitted in vehicle exhaust, which was observed to have a uniquely enriched isotopic signature that was attributed to ethanol's corn origin and use as an alternative

  6. Internal correction of hafnium oxide spectral interferences and mass bias in the determination of platinum in environmental samples using isotope dilution analysis.

    Science.gov (United States)

    Rodríguez-Castrillón, José Angel; Moldovan, Mariella; García Alonso, J Ignacio

    2009-05-01

    A method has been developed for the accurate determination of platinum by isotope dilution analysis, using enriched (194)Pt, in environmental samples containing comparatively high levels of hafnium without any chemical separation. The method is based on the computation of the contribution of hafnium oxide as an independent factor in the observed isotope pattern of platinum in the spiked sample. Under these conditions, the ratio of molar fractions between natural abundance and isotopically enriched platinum was independent of the amount of hafnium present in the sample. Additionally, mass bias was corrected by an internal procedure in which the regression variance was minimised. This was possible as the mass bias factor for hafnium oxide was very close to that of platinum. The final procedure required the measurement of three platinum isotope ratios (192/194, 195/194 and 196/194) to calculate the concentration of platinum in the sample. The methodology has been validated using the reference material "BCR-723 road dust" and has been applied to different environmental matrices (road dust, air particles, bulk wet deposition and epiphytic lichens) collected in the Aspe Valley (Pyrenees Mountains). A full uncertainty budget, using Kragten's spreadsheet method, showed that the total uncertainty was limited only by the uncertainty in the measured isotope ratios and not by the uncertainties of the isotopic composition of platinum and hafnium.

  7. Uranium determination in sea water using the isotopic dilution technique and HR-ICPMS; Determinacao de uranio em agua do mar por meio da tecnica de diluicao isotopica e HR-ICPMS

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Marcio Henrique da Costa; Sarkis, Jorge Eduardo de Souza; Hortellani, Marcos Antonio, E-mail: mhcper@yahoo.com.b, E-mail: jesarkis@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Nascimento, Marcos R.L. [Laboratorio de Pocos de Caldas (LAPOC/CNEN-MG), MG (Brazil)

    2009-07-01

    In this work, the uranium total and the isotopic composition in seawater were calculated using the isotopic dilution applied to the mass spectrometry. The used tracer was a {sup 233}U solution . Near 99 % of the present salts in the matrix were separated by evaporation up to the saturation point. The uranium present in aqueous phase was separated from the matrix through the ion exchange chromatography using the strong Dowex 1 x 8 200-400 mesh anionic resin in chloridric medium 12 M. The analyses were performed in a high resolution mass spectrometer with plasma inductively coupled source. The method validation was done using the seawater standard CASS-4 (Near shore Seawater Reference Material for Trace metals) produced by the NRC C. The procedure allowed to obtain the fractions exempt of salts, having as consequence a greater stability in the analytical signal, and a rise in the instrumental revenue for a great number of samples. The uranium found in the samples was present in levels considered naturals and were obtained with a precision near 2 %

  8. Review: Current applications and challenges for liquid chromatography coupled to isotope ratio mass spectrometry (LC/IRMS).

    Science.gov (United States)

    Godin, Jean-Philippe; McCullagh, James S O

    2011-10-30

    High-precision isotope analysis is recognized as an essential research tool in many fields of study. Until recently, continuous flow isotope ratio mass spectrometry (CF-IRMS) was available via an elemental analyzer or a gas chromatography inlet system for compound-specific analysis of light stable isotopes. In 2004, however, an interface that coupled liquid chromatography with IRMS (LC/IRMS) became commercially available for the first time. This brought the capability for new areas of application, in particular enabling compound-specific δ(13)C analysis of non-volatile, aqueous soluble, compounds from complex mixtures. The interface design brought with it several analytical constraints, however, in particular a lack of compatibility with certain types of chromatography as well as limited flow rates and mobile phase compositions. Routine LC/IRMS methods have, however, been established for measuring the δ(13)C isotopic ratios of underivatized individual compounds for application in archeology, nutrition and physiology, geochemistry, hydrology, soil science and food authenticity. Seven years after its introduction, we review the technical advances and constraints, methodological developments and new applications of liquid chromatography coupled to isotope ratio mass spectrometry.

  9. Chromatography.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities on chromatography. Directions for preparing leaf pigment extracts using alcohol are given, and paper chromatography and thin-layer chromatography are described as modifications of the basic principles of chromatography. (KHR)

  10. Chromatography.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities on chromatography. Directions for preparing leaf pigment extracts using alcohol are given, and paper chromatography and thin-layer chromatography are described as modifications of the basic principles of chromatography. (KHR)

  11. Preparative chromatography for specific δ13C isotopic analysis of individual carbohydrates in environmental samples

    Science.gov (United States)

    Nouara, Amel; Panagiotopoulos, Christos; Balesdent, Jérôme; Sempéré, Richard

    2017-04-01

    Carbohydrates are among the most abundant organic molecules on the Earth and are present in all geochemical systems. Despite their high abundance in the environment, very few studies assessed their origin using molecular carbohydrate isotopic analyses. In contrast with bulk stable isotope analysis (BSIA), which gives the isotopic signature of the entire sample without any specification about its chemical composition, compound specific 13C isotopic analysis of individual sugars (CSIA) offers valuable information about the origin of single molecules. Previous investigations used gas or liquid chromatography coupled with isotope ratio mass spectroscopy (GC-IRMS; HPLC-IRMS) for CSIA of sugars however the former requires δ13C corrections due to the carbon added to the sugar (derivatization) while the later does not provide always adequate separations among monosaccharides. Here we used cation preparative chromatography (Ca2+, Pb2+ and Na+) with refractive index detection in order to produce pure monosaccharide targets for subsequent EA-IRMS analyses. Milli-Q water was used as eluant at a flow rate 0.6 ml min-1. In general, three successive purifications (Ca2+, Pb2+, Ca2+) were sufficient to produce pure compounds. Pure monosaccharides were compared with authentic monosaccharide standards using 1H NMR and/or mass spectroscopy. The detection limit of our technique was about 1µM/sugar with a precision of 10% (n=6). Blanks run with Milli-Q water after three successive purifications resulted in carbon content of 0.13 to 2.77 µgC per collected sugar. These values are much lower than the minimum required amount (5 µgC) of the EA-IRSMS system with a precision of ± 0.35 ‰. Application of our method to environmental samples resulted in δ13C values of glucose, fructose, and levoglucosan in the range of -24 to -26 ‰ (PM10 atmospheric particles), and -15‰ to -22 ‰ for arabinose, glucose, and xylose (marine high molecular dissolved organic matter). These results fall in

  12. Aroma quality assessment of Korean fermented red pepper paste (gochujang) by aroma extract dilution analysis and headspace solid-phase microextraction-gas chromatography-olfactometry.

    Science.gov (United States)

    Kang, Kyung-Mo; Baek, Hyung-Hee

    2014-02-15

    The objective of this study was to assess aroma quality of gochujang using purge and trap, simultaneous steam distillation and solvent extraction (SDE), and headspace solid-phase microextraction (HS-SPME), followed by gas chromatography-olfactometry (GC-O). Nineteen and 28 aroma-active compounds were detected by aroma extract dilution analysis of purge and trap and SDE, respectively. Diallyl disulfide and 3-isobutyl-2-methoxypyrazine played a significant role in the aroma quality of gochujang. Twelve aroma-active compounds were detected by HS-SPME-GC-O based on sample dilution analysis. Methional, diallyl disulfide, and 3-isobutyl-2-methoxypyrazine were the most intense aroma-active compounds. 3-Isobutyl-2-methoxypyrazine was identified for the first time in gochujang.

  13. Method development for the redox speciation analysis of iron by ion chromatography-inductively coupled plasma mass spectrometry and carryover assessment using isotopically labeled analyte analogues.

    Science.gov (United States)

    Wolle, Mesay Mulugeta; Fahrenholz, Timothy; Rahman, G M Mizanur; Pamuku, Matt; Kingston, H M 'Skip'; Browne, Damien

    2014-06-20

    An ion chromatography-inductively coupled plasma mass spectrometry (IC-ICP-MS) method was developed for the redox speciation analysis of iron (Fe) based on in-column complexation of Fe(2+) and Fe(3+) by dipicolinic acid (DPA). The effects of column type, mobile phase composition and molecular ion interference were studied in the method optimization. The carryover of the target species in the IC-ICP-MS method was uniquely and effectively evaluated using isotopically enriched analogues of the analytes ((54)Fe(2+) and (57)Fe(3+)). Standard solutions of the enriched standards were injected into the system following analysis of a sample, and the ratios of the isotopes of iron in the enriched standards were calculated based on the chromatographic peak areas. The concentrations of the analytes carried over from the sample to the enriched standards were determined using the quantitative relationship in isotope dilution mass spectrometry (IDMS). In contrast to the routine way of evaluating carryover effect by injecting a blank solution after sample analysis, the use of isotopically enriched standards identified significant analyte carryover in the present method. Extensive experiments were carried out to systematically identify the source of the carryover and to eliminate the problem; the separation column was found to be the exclusive source. More than 95% of the analyte carryover was eliminated by reducing the length of the column. The detection limit of the IC-ICP-MS method (MDL) for the iron species was 2ngg(-1). The method was used to determine Fe(2+) and Fe(3+) in synthetic aqueous standard solutions and a beverage sample.

  14. Labile pools of Pb in vegetable-growing soils investigated by an isotope dilution method and its influence on soil pH.

    Science.gov (United States)

    Xie, Hong; Huang, Zhi-Yong; Cao, Ying-Lan; Cai, Chao; Zeng, Xiang-Cheng; Li, Jian

    2012-08-01

    Pollution of Pb in the surface of agricultural soils is of increasing concern due to its serious impact on the plant growth and the human health through the food chain. However, the mobility, activity and bioavailability of Pb rely mainly on its various chemical species in soils. In the present study, E and L values, the labile pools of isotopically exchangeable Pb, were estimated using the method of isotope dilution in three vegetable-growing soils. The experiments involved adding a stable enriched isotope ((206)Pb > 96%) to a soil suspension and to soils in which plants are subsequently grown, the labile pools of Pb were then estimated by measuring the isotopic composition of Pb in soil solutions and in the plant tissues, respectively. In addition, the correlation of E values and soil pH was investigated at the ranges of pH 4.5-7.0. The amount of labile Pb in soils was also estimated using different single chemical extractants and a modified BCR approach. The results showed that after spiking the enriched isotopes of (206)Pb (>96%) for 24 hours an equilibration of isotopic exchanges in soil suspensions was achieved, and the isotope ratios of (208)Pb/(206)Pb measured at that time was used for calculating the E(24 h) values. The labile pools of Pb by %E(24 h) values, ranging from 53.2% to 61.7% with an average 57%, were found to be significantly higher (p EDTA and the Σ(BCR) values extracted with the modified BCR approach are helpful to detect the labile pools of Pb in soils. In addition, the negative correlation between soil pH and the labile pools of Pb in soils may be useful for further remediation to reduce the bioavailability of Pb in contaminated soils.

  15. Automation of the isotopic separation of hydrogen through gas chromatography; Automatisation des procedes de separation isotopique des hydrogenes par chromatographie en phase gazeuse

    Energy Technology Data Exchange (ETDEWEB)

    Laquerbe, C.; Steimetz, J.; Demoment, J. [CEA Valduc, 21 - Is-sur-Tille (France); Leterq, D. [CEA Bruyeres-le-Chatel, 91 (France)

    2007-07-01

    The thermal cycling absorption process (TCAP) is a separation technique that can be considered as an evolution of the discontinuous chromatography in gaseous phase used in Cea-Dam for the isotopic separation of tritium. The shift in affinity of the palladium for the 3 hydrogen isotopes allows their separation. In the TCAP process we use the shift of the separation property in terms of operating temperatures: the ability to separate is significant at the ambient temperature while it is almost zero over 1000 C degrees. Preliminary studies have allowed the selection of palladium deposits on alumina as lining. 2 pilot installations have been designed. (A.C.)

  16. Determination of Phytochelatins in Rice by Stable Isotope Labeling Coupled with Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Liu, Ping; Cai, Wen-Jing; Yu, Lei; Yuan, Bi-Feng; Feng, Yu-Qi

    2015-07-01

    A highly sensitive method was developed for the detection of phytochelatins (PCs) in rice by stable isotope labeling coupled with liquid chromatography-electrospray ionization-tandem mass spectrometry (IL-LC-ESI-MS/MS) analysis. A pair of isotope-labeling reagents [ω-bromoacetonylquinolinium bromide (BQB) and BQB-d(7)] were used to label PCs in plant sample and standard PCs, respectively, and then combined prior to LC/MS analysis. The heavy labeled standards were used as the internal standards for quantitation to minimize the matrix and ion suppression effects in MS analysis. In addition, the ionization efficiency of PCs was greatly enhanced through the introduction of a permanent charged moiety of quaternary ammonium of BQB into PCs. The detection sensitivities of PCs upon BQB labeling improved by 14-750-fold, and therefore, PCs can be quantitated using only 5 mg of plant tissue. Furthermore, under cadmium (Cd) stress, we found that the contents of PCs in rice dramatically increased with the increased concentrations and treatment time of Cd. It was worth noting that PC5 was first identified and quantitated in rice tissues under Cd stress in the current study. Taken together, this IL-LC-ESI-MS/MS method demonstrated to be a promising strategy in detection of PCs in plants with high sensitivity and reliability.

  17. A novel absolute quantitative imaging strategy of iron, copper and zinc in brain tissues by Isotope Dilution Laser Ablation ICP-MS.

    Science.gov (United States)

    Feng, Liuxing; Wang, Jun; Li, Hongmei; Luo, Xinzheng; Li, Jiao

    2017-09-01

    Isotope Dilution Laser Ablation ICP-MS (ID-LA-ICP-MS), because of its impressive spatial resolution capacity and precise means for quantification, is one of the most promising tools for in-situ quantitative imaging of trace elements in biological samples. In the ID-LA-ICP-MS strategy for tissue section, the tissue must be maintained intact during the whole sample preparation process. Therefore, how to homogeneously distribute enriched isotope spike on tissue section and how to confirm isotope equilibration between sample and spike are two important challenges. In this study, we reported a novel quantitative imaging strategy for biological thin section based on ID-LA-ICP-MS. To distribute the enriched isotope spikes on tissue section homogeneously, a "border" was constructed to make spike droplet stay on the tissue for isotope exchange. Laser ablation and isotope exchange parameters were also investigated to obtain optimal ID-LA-ICP-MS conditions. The prepared homogeneous in-house standard was used to validate the ID-LA-ICP-MS approach and good agreement with the bulk analysis was achieved. On this basis, quantitative imaging of Fe, Cu and Zn in real mouse brain of Alzheimer's Disease (AD) were measured by the improved methodology. Assessment of the method for real sample was undertaken by comparison of the LA-ICP-MS data with that obtained by micro-XRF. Moreover, comparative analysis of elements distribution and immunohistochemical markers in AD mouse brain was also carried out. The similar distributional patterns demonstrated that the proposed methodology is potential to investigate the correlation of biomarker heterogeneity and elements distribution, and may be useful to understand such complex brain mechanisms in the future. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Filling the gap in Ca input-output budgets in base-poor forest ecosystems: The contribution of non-crystalline phases evidenced by stable isotopic dilution

    Science.gov (United States)

    van der Heijden, Gregory; Legout, Arnaud; Mareschal, Louis; Ranger, Jacques; Dambrine, Etienne

    2017-07-01

    In terrestrial ecosystems, plant-available pools of magnesium and calcium are assumed to be stored in the soil as exchangeable cations adsorbed on the surface of mineral and/or organic particles. The pools of exchangeable magnesium and calcium are measured by ion-exchange soil extractions. These pools are sustained in the long term by the weathering of primary minerals in the soil and atmospheric inputs. This conceptual model is the base of input-output budgets from which soil acidification and the sustainability of soil chemical fertility is inferred. However, this model has been questioned by data from long-term forest ecosystem monitoring sites, particularly for calcium. Quantifying the contribution of atmospheric inputs, ion exchange and weathering of both primary, secondary and non-crystalline phases to tree nutrition in the short term is challenging. In this study, we developed and applied a novel isotopic dilution technique using the stable isotopes of magnesium and calcium to study the contribution of the different soil phases to soil solution chemistry in a very acidic soil. The labile pools of Mg and Ca in the soil (pools in equilibrium with the soil solution) were isotopically labeled by spraying a solution enriched in 26Mg and 44Ca on the soil. Labeled soil columns were then percolated with a dilute acid solution during a 3-month period and the isotopic dilution of the tracers was monitored in the leaching solution, in the exchangeable (2 sequential 1 mol L-1 ammonium acetate extractions) and non-crystalline (2 sequential soil digestions: oxalic acid followed by nitric acid) phases. Significant amounts of Mg and Ca isotope tracer were recovered in the non-crystalline soil phases. These phases represented from 5% to 25% and from 24% to 50%, respectively, of the Mg and Ca labile pools during the experiment. Our results show that non-crystalline phases act as both a source and a sink of calcium and magnesium in the soil, and contribute directly to soil

  19. Quantitative gas chromatography-olfactometry carried out at different dilutions of an extract. Key differences in the odor profiles of four high-quality Spanish aged red wines.

    Science.gov (United States)

    Ferreira, V; Aznar, M; López, R; Cacho, J

    2001-10-01

    Four Spanish aged red wines made in different wine-making areas have been extracted, and the extracts and their 1:5, 1:50, and 1:500 dilutions have been analyzed by a gas chromatography-olfactometry (GC-O) approach in which three judges evaluated odor intensity on a four-point scale. Sixty-nine different odor regions were detected in the GC-O profiles of wines, 63 of which could be identified. GC-O data have been processed to calculate averaged flavor dilution factors (FD). Different ANOVA strategies have been further applied on FD and on intensity data to check for significant differences among wines and to assess the effects of dilution and the judge. Data show that FD and the average intensity of the odorants are strongly correlated (r(2) = 0.892). However, the measurement of intensity represents a quantitative advantage in terms of detecting differences. For some odorants, dilution exerts a critical role in the detection of differences. Significant differences among wines have been found in 30 of the 69 odorants detected in the experiment. Most of these differences are introduced by grape compounds such as methyl benzoate and terpenols, by compounds released by the wood, such as furfural, (Z)-whiskey lactone, Furaneol, 4-propylguaiacol, eugenol, 4-ethylphenol, 2,6-dimethoxyphenol, isoeugenol, and ethyl vanillate, by compounds formed by lactic acid bacteria, such as 2,3-butanedione and acetoine, or by compounds formed during the oxidative storage of wines, such as methional, sotolon, o-aminoacetophenone, and phenylacetic acid. The most important differences from a quantitative point of view are due to 2-methyl-3-mercaptofuran, 4-propylguaiacol, 2,6-dimethoxyphenol, and isoeugenol.

  20. A STUDY ON CARBON ISOTOPE OF CO2 AND CH4 IN WESTERN DIENG PLATEU BY GAS CHROMATOGRAPHY- ISOTOPE RATIO MASS SPECTROMETER (GC-IRMS

    Directory of Open Access Journals (Sweden)

    Hanik Humaida

    2010-06-01

    Full Text Available The carbon isotope can be used to evaluate volcanism phenomenon of volcano. The study of carbon isotope of CO2 and CH4 was carried out in western Dieng Plateau by mass-spectrometer. Before analysis, sampel was separated by gas chromatography using a Porapak-Q column and a FID (Flame Ionization Detector detector. The gas was oxidized by copper oxide at 850oC before being ionized in mass-spectrometer for isotope analysis. The CO2 content in Candradimuka crater (-4.10 O/OO, indicated that the gas may be as volcanic gas. The other CO2 from Sumber and western Gua Jimat, had isotope value  of -10.05 and -12.07 O/OO, respectively, indicating contamination from crustal and subduction material. The carbon isotope of CH4 gas from Pancasan village was -63.42 O/OO, that may be categorized as biogenic gas.   Keywords: isotope, CO2, CH4, Dieng.

  1. Fixation of metals in soil constituents and potential remobilization by hyperaccumulating and non-hyperaccumulating plants: Results from an isotopic dilution study

    Energy Technology Data Exchange (ETDEWEB)

    Hammer, Daniel [Swiss Federal Institute of Technology, ENAC-ISTE-Laboratory of Soil Science, GR B1 423, Station no. 2, Ecublens, 1015 Lausanne (Switzerland); Keller, Catherine [Swiss Federal Institute of Technology, ENAC-ISTE-Laboratory of Soil Science, GR B1 423, Station no. 2, Ecublens, 1015 Lausanne (Switzerland)]. E-mail: keller@cerege.fr; McLaughlin, Michael J. [CSIRO Land and Water, Adelaide Laboratory, PMB 2, Glen Osmond, SA 5064 (Australia); Hamon, Rebecca E. [CSIRO Land and Water, Adelaide Laboratory, PMB 2, Glen Osmond, SA 5064 (Australia)]. E-mail: rebecca.hamon@csiro.au

    2006-10-15

    In this study isotopic dilution methods were used to investigate the hypothesis that access to metals associated with specific chemical components in the soil that are not available to non-accumulator species could be involved in hyperaccumulation. The hyperaccumulator Thlaspi caerulescens and a non-accumulator species, Brassica napus, were grown in Cd and Zn enriched soil components calcite, goethite, charcoal and cryptomelane. The metal enriched components were aged to allow transformation of a proportion of added metals to non-labile forms. Results from the isotopic dilution L value method showed that despite taking up more metals, T. caerulescens accessed the same pool of metals as B. napus. Hence differential access to different solid-phase pools of metals appears to be an unlikely mechanism underlying metal hyperaccumulation. For all components except charcoal, L values for Cd and Zn were greater than the corresponding E values suggesting that E values may tend to underestimate the bioavailable fraction of metals in soils. - Thlaspi caerulescens takes up more Cd and Zn than Brassica napus but from the same pools.

  2. Online stable carbon isotope ratio measurement in formic acid, acetic acid, methanol and ethanol in water by high performance liquid chromatography-isotope ratio mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tagami, Keiko [National Institute of Radiological Sciences, 4-9-1, Anagawa, Inage-ku, Chiba 263-8555 (Japan)], E-mail: k_tagami@nirs.go.jp; Uchida, Shigeo [National Institute of Radiological Sciences, 4-9-1, Anagawa, Inage-ku, Chiba 263-8555 (Japan)

    2008-05-05

    A suitable analysis condition was determined for high performance liquid chromatography-isotope ratio mass spectrometry (HPLC-IRMS) while making sequential measurements of stable carbon isotope ratios of {delta}{sup 13}C in formic acid, acetic acid, methanol and ethanol dissolved in water. For this online column separation method, organic reagents are not applicable due to carbon contamination; thus, water and KH{sub 2}PO{sub 4} at low concentrations were tested as mobile phase in combination with a HyPURITY AQUASTAR{sup TM} column. Formic acid, acetic acid, methanol and ethanol were separated when 2 mM KH{sub 2}PO{sub 4} aqueous solution was used. Under the determined analysis condition for HPLC-IRMS, carbon concentrations could be measured quantitatively as well as carbon isotope ratio when carbon concentration was higher than 0.4 mM L for each chemical.

  3. Determination of key aroma compounds in the crumb of a three-stage sourdough rye bread by stable isotope dilution assays and sensory studies.

    Science.gov (United States)

    Kirchhoff, E; Schieberle, P

    2001-09-01

    An investigation of the volatile fraction of a freshly prepared sourdough rye bread crumb by means of the aroma extract dilution analysis (AEDA), followed by identification experiments, revealed 22 flavor compounds in the flavor dilution (FD) factor range of 128 to 2048. Quantitations performed by stable isotope dilution assays (SIDA) and a calculation of odor activity values (OAV; ratio of concentration to odor threshold) revealed the following as contributors to the overall crumb flavor: 3-methylbutanal (malty), (E)-2-nonenal (green, fatty), (E,E)-2,4-decadienal (fatty, waxy), hexanal (green), acetic acid (sour, pungent), phenylacetaldehyde (honey-like), methional (boiled potato-like), vanillin (vanilla-like), 2,3-butandione (buttery), 3-hydroxy-4,5-dimethyl-2(5H)-furanone (spicy), and 2- and 3-methylbutanoic acid (sweaty). Using either citrate buffer, starch, or deodorized crumb as model matrixes, the typical malty and sour rye bread crumb flavor was reproduced by adding a mixture of 20 reference odorants in the "natural" concentrations as quantitatively determined in the fresh crumb.

  4. Evaluation of urinary metanephrine and normetanephrine enzyme immunoassay (ELISA) kits by comparison with isotope dilution mass spectrometry

    NARCIS (Netherlands)

    Wolthers, BG; Kema, IP; Volmer, M; Wesemann, R; Westermann, J; Manz, B

    1997-01-01

    Determination of urinary 3-O-methylated catecholamines (metanephrines) is generally considered a principal test for the clinical chemical diagnosis of pheochromocytoma and is currently performed predominantly with chromatographic techniques such as gas-liquid chromatography and HPLC. Enzyme immunoas

  5. Total N difference method and 15N isotope dilution methode - A comparative study on N-fixation

    OpenAIRE

    2002-01-01

    In the study, the 15N fixation of a number of green manure crops were studied using either the 15N dilution technique, or the simple total N difference method. The results of the two methods were not very different, and the total N difference method seemed to give as good results as the more complicated and expencive 15N dillution method.

  6. Gas Chromatography-Mass Spectrometry Based Isotopic Abundance Ratio Analysis of Biofield Energy Treated Methyl-2-napthylether (Nerolin)

    OpenAIRE

    2016-01-01

    Methyl-2-napthylether (nerolin) is an organic compound and has the applications in pharmaceutical, and perfume industry. The stable isotope ratio analysis is increasing importance in various field of scientific research. The objective of the current study was to evaluate the effect of the biofield energy treatment on the isotopic abundance ratios of PM+1/PM(2H/1H or 13C/12C or 17O/16O) and PM+2/PM (18O/16O) in nerolin using the gas chromatography-mass spectrometry (GC-MS). The compound neroli...

  7. A practical method for the determination of total selenium in environmental samples using isotope dilution-hydride generation-inductively coupled plasma-mass spectrometry

    Science.gov (United States)

    Kleckner, Amy E.; Kakouros, Evangelos; Stewart, A. Robin

    2017-01-01

    A safe, practical, and accurate method for the determination of selenium (Se) in range of environmental samples was developed. Small sample masses, 5–20 mg, were amended with 82Se enriched isotope for the isotope dilution (ID), preceding a multi-step wet digestion with nitric acid (HNO3) and hydrogen peroxide (H2O2). Samples were incubated in an autoclave for 3 h at 20 psi and 126°C. Digestates were subsequently reduced with concentrated hydrochloric acid to Se(IV) the most favorable valence for hydride generation (HG). The solutions were then analyzed on an ICP-MS equipped with Flow Injection system (FIAS-400). Polyatomic, isobaric, and background interferences were removed through the use of HG and ID with an 82Se enriched isotope spike. Recoveries for certified reference materials were determined and averaged 96% for biological tissues (NRCC DOLT3, DOLT4, DORM2, TORT2, and TORT3, and NIST 2976) and 108% for estuarine sediment (NRCC PACS2) with an average coefficient of variation for replicate measurements of ∼ 3.5%. Limit of detection was 0.13 ng Se g−1 dry weight or 0.19 ng Se L−1. This method can be broadly applied to biological tissues, sediments, suspended particulates, and water samples with minimal modifications making this method highly useful for assessing the ecotoxicology of total Se in aquatic ecosystems.

  8. Verification of key odorants in rose oil by gas chromatography-olfactometry/aroma extract dilution analysis, odour activity value and aroma recombination.

    Science.gov (United States)

    Xiao, Zuobing; Li, Jing; Niu, Yunwei; Liu, Qiang; Liu, Junhua

    2017-03-28

    Rose oil is much too expensive but very popular. It's well known that the flower oil's aroma profile hasn't been intensively investigated. In order to verify the aroma profile of rose oil, the synthetic blend of odorants was prepared and then compared with the original rose oil using electronic nose analysis (ENA) combined with quantitative descriptive analysis (QDA). The odorants from rose oils were screened out by Gas Chromatography-Olfactometry/aroma extract dilution analysis (GC-O/AEDA) combined with odour activity value (OAV). Both ENA and QDA indicated the recombination model derived from OAV and GC-O/AEDA closely resembled the original rose oil. The experiment results show that rose oxide, linalool, α-pinene, β-pinene, nonanal, heptanal citronellal, phenyl ethyl alcohol, benzyl alcohol, eugenol, methyl eugenol, β-citronellol, hexyl acetate, β-ionone, nerol, etc. are very important constituent to rose oil aroma profile.

  9. Activity coefficients at infinite dilution for solutes in the trioctylmethylammonium bis(trifluoromethylsulfonyl)imide ionic liquid using gas-liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Gwala, Nobuhle V. [Department of Chemistry, Durban University of Technology, P.O. Box 1334, Durban 4000 (South Africa); Deenadayalu, Nirmala, E-mail: NirmalaD@dut.ac.z [Department of Chemistry, Durban University of Technology, P.O. Box 1334, Durban 4000 (South Africa); Tumba, Kaniki; Ramjugernath, Deresh [Thermodynamics Research Unit, School of Chemical Engineering, University of KwaZulu-Natal, Howard College Campus, King George V Avenue, Durban 4001 (South Africa)

    2010-02-15

    The activity coefficient at infinite dilution (gamma{sub 13}{sup i}nfinity) for 30 solutes: alkanes, alkenes, cycloalkanes, alkynes, ketones, alcohols, and aromatic compounds was determined from gas-liquid chromatography (glc) measurements at three temperatures (303.15, 313.15, and 323.15) K. The ionic liquid: trioctylmethylammonium bis(trifluoromethylsulfonyl)imide, was used as the stationary phase. For each temperature, gamma{sub 13}{sup i}nfinity values were determined using two columns with different mass percent packing of the ionic liquid. The selectivity (S{sub 12}{sup i}nfinity) value was calculated from the gamma{sub 13}{sup i}nfinity to determine the suitability of the solvent as a potential entrainer for extractive distillation in the separation of an hexane/benzene mixture, indicative of a typical industrial separation problem for benchmarking purposes.

  10. Determination of the origin of urinary norandrosterone traces by gas chromatography combustion isotope ratio mass spectrometry.

    Science.gov (United States)

    Hebestreit, Moritz; Flenker, Ulrich; Fusshöller, Gregor; Geyer, Hans; Güntner, Ute; Mareck, Ute; Piper, Thomas; Thevis, Mario; Ayotte, Christiane; Schänzer, Wilhelm

    2006-09-01

    On the one hand, 19-norandrosterone (NA) is the most abundant metabolite of the synthetic anabolic steroid 19-nortestosterone and related prohormones. On the other hand, small amounts are biosynthesized by pregnant women and further evidence exists for physiological origin of this compound. The World Anti-Doping Agency (WADA) formerly introduced threshold concentrations of 2 or 5 ng of NA per ml of urine to discriminate 19-nortestosterone abuse from biosynthetic origin. Recent findings showed however, that formation of NA resulting in concentrations in the range of the threshold levels might be due to demethylation of androsterone in urine, and the WADA 2006 Prohibited List has defined NA as endogenous steroid. To elucidate the endogenous or exogenous origin of NA, (13)C/(12)C-analysis is the method of choice since synthetic 19-nortestosterone is derived from C(3)-plants by partial synthesis and shows delta(13)C(VPDB)-values of around -28 per thousand. Endogenous steroids are less depleted in (13)C due to a dietary mixture of C(3)- and C(4)-plants. An extensive cleanup based on two high performance liquid chromatography cleanup steps was applied to quality control and doping control samples, which contained NA in concentrations down to 2 ng per ml of urine. (13)C/(12)C-ratios of NA, androsterone and etiocholanolone were measured by gas chromatography/combustion/isotope ratio mass spectrometry. By comparing delta(13)C(VPDB)-values of androsterone as endogenous reference compound with NA, the origin of NA in doping control samples was determined as either endogenous or exogenous.

  11. Quantitation of N2-[1-(1-carboxy)ethyl]folic acid, a nonenzymatic glycation product of folic acid, in fortified foods and model cookies by a Stable isotope dilution assay.

    Science.gov (United States)

    Rychlik, Michael; Mayr, Anja

    2005-06-29

    A stable isotope dilution assay (SIDA) for the quantitation of N(2)-[1-(carboxy)ethyl]folic acid (CEF) has been developed by using [(2)H(4)]CEF as the internal standard. After sample cleanup by anion exchange chromatography, the three-dimensional specifity of liquid chromatography-tandem mass spectrometry enabled unequivocal determination of the nonenzymatic glycation product of folic acid (FA). When CEF was added to cornstarch, the detection limit for CEF was found to be 0.4 microg/100 g, and a recovery of 98.5% was determined. In analyses of cookies, the intra-assay coefficient of variation was 8.0% (n = 5). Application of the SIDA to commercial cookies produced from wheat flour fortified with FA revealed CEF contents of up to 7.1 microg/100 g, which accounted for approximately 10-20% of the cookies' FA content. In baby foods, multivitamin juices, and multivitamin sweets, however, CEF was not detectable. Further studies on CEF formation during baking of cookies made from fortified flour and different carbohydrates revealed that fructose was most effective in generating CEF followed by glucose, lactose, and sucrose with 12.5, 3.9, 2.5, and 2.5 microg/100 g of dry mass, respectively. During baking, approximately 50% of FA was retained for both monosaccharides fructose and glucose, and 77% as well as 85% of its initial content was retained for the disaccharides lactose and sucrose, respectively. Of the degraded amount of FA, CEF comprised 28% for fructose as well as 18, 12, and 8% for sucrose, lactose, and glucose, respectively. Therefore, CEF can be considered an important degradation product of FA in baked foods made from fructose. To retain a maximum amount of FA, products should rather be baked with sucrose than with reducing carbohydrates.

  12. Pre-column dilution large volume injection ultra-high performance liquid chromatography-tandem mass spectrometry for the analysis of multi-class pesticides in cabbages.

    Science.gov (United States)

    Zhong, Qisheng; Shen, Lingling; Liu, Jiaqi; Yu, Dianbao; Li, Siming; Yao, Jinting; Zhan, Song; Huang, Taohong; Hashi, Yuki; Kawano, Shin-ichi; Liu, Zhaofeng; Zhou, Ting

    2016-04-15

    Pre-column dilution large volume injection (PD-LVI), a novel sample injection technique for reverse phase ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), was developed in this study. The PD-LVI UHPLC-MS/MS system was designed by slightly modifying the commercial UHPLC-MS/MS equipment with a mixer chamber. During the procedure of PD-LVI, sample solution of 200μL was directly carried by the organic mobile phase to the mixer and diluted with the aqueous mobile phase. After the mixture was introduced to the UHPLC column in a mobile phase of acetonitrile-water (15/85, v/v), the target analytes were stacked on the head of the column until following separation. Using QuEChERS extraction, no additional steps such as solvent evaporation or residue redissolution were needed before injection. The features of PD-LVI UHPLC-MS/MS system were systematically investigated, including the injection volume, the mixer volume, the precondition time and the gradient elution. The efficiency of this approach was demonstrated by direct analysis of 24 pesticides in cabbages. Under the optimized conditions, low limits of detection (0.00074-0.8 ng/kg) were obtained. The recoveries were in the range of 63.3-109% with relative standard deviations less than 8.1%. Compared with common UHPLC-MS/MS technique, PD-LVI UHPLC-MS/MS showed significant advantages such as excellent sensitivity and reliability. The mechanism of PD-LVI was demonstrated to be based on the column-head stacking effect with pre-column dilution. Based on the results, PD-LVI as a simple and effective sample injection technique of reverse phase UHPLC-MS/MS for the analysis of trace analytes in complex samples showed a great promising prospect.

  13. Isotopic fractionation of fentanyl and its deuterated analogues by capillary gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Sera, Shoji; Goromaru, Tsuyoshi [Fukuyama Univ., Hiroshima (Japan)

    1997-12-01

    Isotopic fractionation of fentanyl (FT) and its deuterated analogues by gas chromatography using capillary columns (CBP1 and CBP5) has been investigated. Seven kinds of analogues were labeled with 5 to 19 deuterium atoms at the anilino, propionyl and/or phenylethyl group of FT. The retention times of deuterated FT in CBP1 and CBP5 columns are inversely proportional to the number of labeled deuterium atoms in the molecule. The difference in free enegy changes ({Delta}{Delta}G) had a linear relationship with the number of labeled deuterium atoms, except for labeling at anilino and phenylethyl group. The contribution of a deuterium atom to the {Delta}{Delta}G value was estimated to be 1.13 cal/mol in CBP1 and 1.40 cal/mol in CBP5, respectively. While, its contribution in the propiony group was 2.84 cal/mol in CBP1 and 2.48 cal/mol in CBP5, respectively. An important factor in separation by GC may differences in interactions between the stationary phase of the column with the three dimensional protrusive moiety in the molecule. (author)

  14. Automated two-step chromatography using an ÄKTA equipped with in-line dilution capability.

    Science.gov (United States)

    Winters, Dwight; Chu, Carolyn; Walker, Kenneth

    2015-12-11

    There has been a great emphasis on developing higher-throughput protein purification techniques to screen potential human therapeutics faster and more efficiently. Not only is it desirable to have high-throughput purification for initial screens but it is also desirable to efficiently purify selected protein therapeutics in the amounts and purity required for definitive assays. Current automated tandem technologies involve size exclusion as a second step that often fails to generate the required purity, is not robust and can only be operated at a limited scale. We have modified an ÄKTA to enable in-line dilution, assuring that the automated loading of a second column from a first column elution can be modified to a pH and ionic strength which is suitable for binding to the second column. For example, Protein A can be employed as a first step followed by direct loading on to a cation exchange column by conditioning the Protein A elution using the in-line diluter. Using this method as described, up to six samples of 1L each can be purified through two columns without human intervention per day per machine, and the system produces good yields of purified protein over a wide range of loading levels (12-300mg). In addition, the system employs guanidine HCl regeneration, followed by a sodium hydroxide wash between purification runs, minimizing the possibility of carryover contamination. The system is described at the 5mL and the 10mL column sizes; however, it could readily be programed for 100mL columns to enable larger-scale purifications. Using this system to automate two-column purifications minimizes human intervention, increases efficiency and minimizes the risk of human error.

  15. Carbon isotopic ratio analysis by gas chromatography/combustion/isotope ratio mass spectrometry for the detection of gamma-hydroxybutyric acid (GHB) administration to humans.

    Science.gov (United States)

    Saudan, Christophe; Augsburger, Marc; Mangin, Patrice; Saugy, Martial

    2007-01-01

    Since GHB (gamma-hydroxybutyric acid) is naturally produced in the human body, clinical and forensic toxicologists must be able to discriminate between endogenous levels and a concentration resulting from exposure. To suggest an alternative to the use of interpretative concentration cut-offs, the detection of exogenous GHB in urine specimens was investigated by means of gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). GHB was isolated from urinary matrix by successive purification on Oasis MCX and Bond Elute SAX solid-phase extraction (SPE) cartridges prior to high-performance liquid chromatography (HPLC) fractioning using an Atlantis dC18 column eluted with a mixture of formic acid and methanol. Subsequent intramolecular esterification of GHB leading to the formation of gamma-butyrolactone (GBL) was carried out to avoid introduction of additional carbon atoms for carbon isotopic ratio analysis. A precision of 0.3 per thousand was determined using this IRMS method for samples at GHB concentrations of 10 mg/L. The (13)C/(12)C ratios of GHB in samples of subjects exposed to the drug ranged from -32.1 to -42.1 per thousand, whereas the results obtained for samples containing GHB of endogenous origin at concentration levels less than 10 mg/L were in the range -23.5 to -27.0 per thousand. Therefore, these preliminary results show that a possible discrimination between endogenous and exogenous GHB can be made using carbon isotopic ratio analyses.

  16. Application of Isotope Dilution Mass Spectrometry for Reference Measurements of Cadmium. Copper, Mercury, Lead, Zinc and Methyl Mercury in Marine Sediment Sample

    Directory of Open Access Journals (Sweden)

    Vasileva E.

    2013-04-01

    Full Text Available Marine sediment was selected as a test sample for the laboratory inter-comparison studies organized by the Environment Laboratoryes of the International Atomic Energy. The analytical procedure to establish the reference values for the Cd, Cu, Hg, Methyl Hg, Pb and Zn amount contents was based on Isotope Dilution Inductively Coupled Plasma-Mass Spectrometry (ID ICP-MS applied as a primary method of measurement..The Hg and Methyl Hg determination will be detailed more specifically because of the problems encountered with this element, including sample homogeneity issues, memory effects and possible matrix effects during the ICP- MS measurement stage. Reference values, traceable to the SI, with total uncertainties of less than 2% relative expanded uncertainty (k=2 were obtained for Cd, Cu, Zn and Pb and around 5% for Hg and CH3Hg.

  17. Determination of picomolar levels of platinum in estuarine waters: a comparison of cathodic stripping voltammetry and isotope dilution-inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Obata, Hajime; Yoshida, Tetsuaki; Ogawa, Hiroshi

    2006-10-27

    A comparative study to determine picomolar concentrations of platinum in natural waters was performed using two different analytical techniques. Results obtained by cathodic stripping voltammetry (CSV) were compared with those obtained by isotope dilution-inductively coupled plasma mass spectrometry (ID-ICPMS) combined with anion exchange resin column extraction method. Using successive UV irradiations with low-pressure mercury (L-Hg) lamp for 4h prior to CSV analysis, the results of both methods were comparable. Without adequate photolytic decomposition, the results obtained using CSV were generally lower than those obtained using ID-ICPMS in the estuarine waters around Tokyo Bay. This difference implies the presence of organically complexed Pt species in the estuarine waters. The Pt enrichment in the middle of the Tokyo Bay estuaries probably reflects the anthropogenic release of Pt from highly populated areas in Tokyo.

  18. Volatile organic compounds in whole blood - determination by heated dynamic headspace purge and trap isotope-dilution GC/MS. Special report, November 1984-August 1987

    Energy Technology Data Exchange (ETDEWEB)

    Cramer, P.H.; Boggess, K.E.; Hosenfeld, J.M.

    1987-07-01

    The method described was developed for the determination of a selected list of 30 organic compounds in whole human blood. The method is a heated dynamic head-space purge and trap gas chromatographic method using mass spectrometry in the limited mass-scan mode. A whole blood sample is diluted with organic free water and the mixture fortified with isotopically labeled compounds. The mixture is subsequently heated to 50/sup 0/C while stirred, and the volatile components are purged from the mixture and collected on an adsorbent trap. The volatile compounds are thermally desorbed from the trap onto a wide-bore fused-silica capillary column. Detection of the compounds is accomplished using mass spectrometry in the limited mass-scan mode where only selected ions are scanned. Quantitation of the analytes is accomplished by using the specific ion responses from standards of the analytes and their corresponding labeled analogs or internal standards.

  19. Determination of low methylmercury concentrations in peat soil samples by isotope dilution GC-ICP-MS using distillation and solvent extraction methods.

    Science.gov (United States)

    Pietilä, Heidi; Perämäki, Paavo; Piispanen, Juha; Starr, Mike; Nieminen, Tiina; Kantola, Marjatta; Ukonmaanaho, Liisa

    2015-04-01

    Most often, only total mercury concentrations in soil samples are determined in environmental studies. However, the determination of extremely toxic methylmercury (MeHg) in addition to the total mercury is critical to understand the biogeochemistry of mercury in the environment. In this study, N2-assisted distillation and acidic KBr/CuSO4 solvent extraction methods were applied to isolate MeHg from wet peat soil samples collected from boreal forest catchments. Determination of MeHg was performed using a purge and trap GC-ICP-MS technique with a species-specific isotope dilution quantification. Distillation is known to be more prone to artificial MeHg formation compared to solvent extraction which may result in the erroneous MeHg results, especially with samples containing high amounts of inorganic mercury. However, methylation of inorganic mercury during the distillation step had no effect on the reliability of the final MeHg results when natural peat soil samples were distilled. MeHg concentrations determined in peat soil samples after distillation were compared to those determined after the solvent extraction method. MeHg concentrations in peat soil samples varied from 0.8 to 18 μg kg(-1) (dry weight) and the results obtained with the two different methods did not differ significantly (p=0.05). The distillation method with an isotope dilution GC-ICP-MS was shown to be a reliable method for the determination of low MeHg concentrations in unpolluted soil samples. Furthermore, the distillation method is solvent-free and less time-consuming and labor-intensive when compared to the solvent extraction method. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Accurate determination of sulfur in gasoline and related fuel samples using isotope dilution ICP-MS with direct sample injection and microwave-assisted digestion.

    Science.gov (United States)

    Heilmann, Jens; Boulyga, Sergei F; Heumann, Klaus G

    2004-09-01

    Inductively coupled plasma isotope-dilution mass spectrometry (ICP-IDMS) with direct injection of isotope-diluted samples into the plasma, using a direct injection high-efficiency nebulizer (DIHEN), was applied for accurate sulfur determinations in sulfur-free premium gasoline, gas oil, diesel fuel, and heating oil. For direct injection a micro-emulsion consisting of the corresponding organic sample and an aqueous 34S-enriched spike solution with additions of tetrahydronaphthalene and Triton X-100, was prepared. The ICP-MS parameters were optimized with respect to high sulfur ion intensities, low mass-bias values, and high precision of 32S/34S ratio measurements. For validation of the DIHEN-ICP-IDMS method two certified gas oil reference materials (BCR 107 and BCR 672) were analyzed. For comparison a wet-chemical ICP-IDMS method was applied with microwave-assisted digestion using decomposition of samples in a closed quartz vessel inserted into a normal microwave system. The results from both ICP-IDMS methods agree well with the certified values of the reference materials and also with each other for analyses of other samples. However, the standard deviation of DIHEN-ICP-IDMS was about a factor of two higher (5-6% RSD at concentration levels above 100 mircog g(-1)) compared with those of wet-chemical ICP-IDMS, mainly due to inhomogeneities of the micro-emulsion, which causes additional plasma instabilities. Detection limits of 4 and 18 microg g(-1) were obtained for ICP-IDMS in connection with microwave-assisted digestion and DIHEN-ICP-IDMS, respectively, with a sulfur background of the used Milli-Q water as the main limiting factor for both methods.

  1. Accurate determination of sulfur in gasoline and related fuel samples using isotope dilution ICP-MS with direct sample injection and microwave-assisted digestion

    Energy Technology Data Exchange (ETDEWEB)

    Heilmann, Jens; Boulyga, Sergei F.; Heumann, Klaus G. [Johannes Gutenberg-University, Institute of Inorganic Chemistry and Analytical Chemistry, Mainz (Germany)

    2004-09-01

    Inductively coupled plasma isotope-dilution mass spectrometry (ICP-IDMS) with direct injection of isotope-diluted samples into the plasma, using a direct injection high-efficiency nebulizer (DIHEN), was applied for accurate sulfur determinations in sulfur-free premium gasoline, gas oil, diesel fuel, and heating oil. For direct injection a micro-emulsion consisting of the corresponding organic sample and an aqueous {sup 34}S-enriched spike solution with additions of tetrahydronaphthalene and Triton X-100, was prepared. The ICP-MS parameters were optimized with respect to high sulfur ion intensities, low mass-bias values, and high precision of {sup 32}S/{sup 34}S ratio measurements. For validation of the DIHEN-ICP-IDMS method two certified gas oil reference materials (BCR 107 and BCR 672) were analyzed. For comparison a wet-chemical ICP-IDMS method was applied with microwave-assisted digestion using decomposition of samples in a closed quartz vessel inserted into a normal microwave system. The results from both ICP-IDMS methods agree well with the certified values of the reference materials and also with each other for analyses of other samples. However, the standard deviation of DIHEN-ICP-IDMS was about a factor of two higher (5-6% RSD at concentration levels above 100 {mu}g g{sup -1}) compared with those of wet-chemical ICP-IDMS, mainly due to inhomogeneities of the micro-emulsion, which causes additional plasma instabilities. Detection limits of 4 and 18 {mu}g g{sup -1} were obtained for ICP-IDMS in connection with microwave-assisted digestion and DIHEN-ICP-IDMS, respectively, with a sulfur background of the used Milli-Q water as the main limiting factor for both methods. (orig.)

  2. The potential of Isotope Ratio Mass Spectrometry (IRMS) and gas chromatography-IRMS analysis of triacetone triperoxide in forensic explosives investigations

    NARCIS (Netherlands)

    Bezemer, K.D.B.; Koeberg, M.; Heijden, A.E.D.M. van der; Driel, C.A. va; Blaga, C.; Bruinsma, J.; Asten, A.C. van

    2016-01-01

    Studying links between triacetone triperoxide (TATP) samples from crime scenes and suspects can assist in criminal investigations. Isotope ratio mass spectrometry (IRMS) and gas chromatography (GC)-IRMS were used to measure the isotopic compositions of TATP and its precursors acetone and hydrogen pe

  3. Dansylation isotope labeling liquid chromatography mass spectrometry for parallel profiling of human urinary and fecal submetabolomes

    Energy Technology Data Exchange (ETDEWEB)

    Su, Xiaoling [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Wang, Nan [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2 (Canada); Chen, Deying [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Li, Yunong [Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2 (Canada); Lu, Yingfeng [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Huan, Tao [Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2 (Canada); Xu, Wei [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Li, Liang, E-mail: Liang.Li@ualberta.ca [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China); Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2 (Canada); Li, Lanjuan, E-mail: ljli@zju.edu.cn [State Key Laboratory and Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310003 (China)

    2016-01-15

    Human urine and feces can be non-invasively collected for metabolomics-based disease biomarker discovery research. Because urinary and fecal metabolomes are thought to be different, analysis of both biospecimens may generate a more comprehensive metabolomic profile that can be better related to the health state of an individual. Herein we describe a method of using differential chemical isotope labeling (CIL) liquid chromatography mass spectrometry (LC-MS) for parallel metabolomic profiling of urine and feces. Dansylation labeling was used to quantify the amine/phenol submetabolome changes among different samples based on {sup 12}C-labeling of individual samples and {sup 13}C-labeling of a pooled urine or pooled feces and subsequent analysis of the {sup 13}C-/{sup 12}C-labeled mixture by LC-MS. The pooled urine and pooled feces are further differentially labeled, mixed and then analyzed by LC-MS in order to relate the metabolite concentrations of the common metabolites found in both biospecimens. This method offers a means of direct comparison of urinary and fecal submetabolomes. We evaluated the analytical performance and demonstrated the utility of this method in the analysis of urine and feces collected daily from three healthy individuals for 7 days. On average, 2534 ± 113 (n = 126) peak pairs or metabolites could be detected from a urine sample, while 2507 ± 77 (n = 63) peak pairs were detected from a fecal sample. In total, 5372 unique peak pairs were detected from all the samples combined; 3089 and 3012 pairs were found in urine and feces, respectively. These results reveal that the urine and fecal metabolomes are very different, thereby justifying the consideration of using both biospecimens to increase the probability of finding specific biomarkers of diseases. Furthermore, the CIL LC-MS method described can be used to perform parallel quantitative analysis of urine and feces, resulting in more complete coverage of the human metabolome

  4. Detection of dehydroepiandrosterone misuse by means of gas chromatography- combustion-isotope ratio mass spectrometry.

    Science.gov (United States)

    Mareck, Ute; Geyer, Hans; Flenker, Ulrich; Piper, Thomas; Thevis, Mario; Schänzer, Wilhelm

    2007-01-01

    According to World Anti-Doping Agency (WADA) rules (WADA Technical Document-TD2004EAAS) urine samples containing dehydroepiandrosterone (DHEA) concentrations greater than 100 ng ML(-1) shall be submitted to isotope ratio mass spectrometry (IRMS) analysis. The threshold concentration is based on the equivalent to the glucuronide, and the DHEA concentrations have to be adjusted for a specific gravity value of 1.020. In 2006, 11,012 doping control urine samples from national and international federations were analyzed in the Cologne doping control laboratory, 100 (0.9%) of them yielding concentrations of DHEA greater than 100 ng mL(-1). Sixty-eight percent of the specimens showed specific gravity values higher than 1.020, 52% originated from soccer players, 95% were taken in competition, 85% were male urines, 99% of the IRMS results did not indicate an application of testosterone or related prohormones. Only one urine sample was reported as an adverse analytical finding having 319 ng mL(-1) DHEA (screening result), more than 10,000 ng mL(-1) androsterone and depleted carbon isotope ratio values for the testosterone metabolites androsterone and etiocholanolone. Statistical evaluation showed significantly different DHEA concentrations between specimens taken in- and out-of- competition, whereas females showed smaller DHEA values than males for both types of control. Also a strong influence of the DHEA excretion on different sport disciplines was detectable. The highest DHEA values were detected for game sports (soccer, basketball, handball, ice hockey), followed by boxing and wrestling. In 2007, 6622 doping control urine samples were analyzed for 3alpha,5-cyclo-5alpha-androstan-6beta-ol-17-one (3alpha,5-cyclo), a DHEA metabolite which was described as a useful gas chromatography-mass spectrometry (GC-MS) screening marker for DHEA abuse. Nineteen urine specimens showed concentrations higher than the suggested threshold of 140 ng mL(-1), six urine samples yielded

  5. An Ultrahigh Precision, High-Frequency Dissolved Inorganic Carbon Analyzer Based on Dual Isotope Dilution and Cavity Ring-Down Spectroscopy.

    Science.gov (United States)

    Huang, Kuan; Cassar, Nicolas; Jonsson, Bror; Cai, Wei-jun; Bender, Michael L

    2015-07-21

    We present a novel method for continuous and automated shipboard measurements of dissolved inorganic carbon concentration ([DIC]) in surface water. The method is based on dual isotope dilution and cavity ring-down spectroscopy (DID-CRDS). In this method, seawater is continuously sampled and mixed with a flow of NaH(13)CO3 solution that is also enriched in deuterated water (the spike). The isotopic composition of CO2 (δ(13)C(spiked_sample)) derived from the DIC in the mixture, and the D/H ratio of the mixed water (δD(spiked_sample)), are measured by CRDS analyzers. The D/H of the water in the mixture allows accurate estimates of the mixing ratio of the sample and the spike. [DIC] of the sample is then calculated from the mixing ratio, [DI(13)C] of the spike, and δ(13)C(spiked_sample). In the laboratory, the precision of the method is test was conducted in the Delaware Bay and Estuary. For 2 min average [DIC], a precision of <0.03% was achieved. Measurements from the DID-CRDS showed good agreement with independent measurements of discrete samples using the well-established coulometric method (mean difference = -1.14 ± 1.68 μmol kg(-1)), and the nondispersive infrared(NDIR)-based methods (mean difference = -0.9 ± 4.73 μmol kg(-1)).

  6. Quantitation using a stable isotope dilution assay (SIDA) and thresholds of taste-active pyroglutamyl decapeptide ethyl esters (PGDPEs) in sake.

    Science.gov (United States)

    Hashizume, Katsumi; Ito, Toshiko; Igarashi, Shinya

    2017-03-01

    A stable isotope dilution assay (SIDA) for two taste-active pyroglutamyl decapeptide ethyl esters (PGDPE1; (pGlu)LFGPNVNPWCOOC2H5, PGDPE2; (pGlu)LFNPSTNPWCOOC2H5) in sake was developed using deuterated isotopes and high-resolution mass spectrometry. Recognition thresholds of PGDPEs in sake were estimated as 3.8 μg/L for PGDPE1 and 8.1 μg/L for PGDPE2, evaluated using 11 student panelists aged in their twenties. Quantitated concentrations in 18 commercial sake samples ranged from 0 to 27 μg/L for PGDPE1 and from 0 to 202 μg/L for PGDPE2. The maximum levels of PGDPE1 and PGDPE2 in the sake samples were approximately 8 and 25 times higher than the estimated recognition thresholds, respectively. The results indicated that PGDPEs may play significant sensory roles in the sake. The level of PGDPEs in unpasteurized sake samples decreased during storage for 50 days at 6 °C, suggesting PGDPEs may be enzymatically decomposed.

  7. Stable Isotope Labeling Strategy for Curcumin Metabolite Study in Human Liver Microsomes by Liquid Chromatography-Tandem Mass Spectrometry

    Science.gov (United States)

    Gao, Dan; Chen, Xiaowu; Yang, Xiaomei; Wu, Qin; Jin, Feng; Wen, Hongliang; Jiang, Yuyang; Liu, Hongxia

    2015-04-01

    The identification of drug metabolites is very important in drug development. Nowadays, the most widely used methods are isotopes and mass spectrometry. However, the commercial isotopic labeled reagents are usually very expensive, and the rapid and convenient identification of metabolites is still difficult. In this paper, an 18O isotope labeling strategy was developed and the isotopes were used as a tool to identify drug metabolites using mass spectrometry. Curcumin was selected as a model drug to evaluate the established method, and the 18O labeled curcumin was successfully synthesized. The non-labeled and 18O labeled curcumin were simultaneously metabolized in human liver microsomes (HLMs) and analyzed by liquid chromatography/mass spectrometry (LC-MS). The two groups of chromatograms obtained from metabolic reaction mixture with and without cofactors were compared and analyzed using Metabolynx software (Waters Corp., Milford, MA, USA). The mass spectra of the newly appearing chromatographic peaks in the experimental sample were further analyzed to find the metabolite candidates. Their chemical structures were confirmed by tandem mass spectrometry. Three metabolites, including two reduction products and a glucuronide conjugate, were successfully detected under their specific HLMs metabolic conditions, which were in accordance with the literature reported results. The results demonstrated that the developed isotope labeling method, together with post-acquisition data processing using Metabolynx software, could be used for fast identification of new drug metabolites.

  8. Stable isotope dilution analysis of salicylic acid and hydroquinone in human skin samples by gas chromatography with mass spectrometric detection.

    Science.gov (United States)

    Judefeind, Anja; van Rensburg, Peet Jansen; Langelaar, Stephan; du Plessis, Jeanetta

    2007-06-01

    A sensitive and accurate gas chromatographic-mass spectrometric (GC-MS) method has been developed for the quantitative determination of salicylic acid (SA) and hydroquinone (HQ) from human skin samples and cosmetic emulsions. Deuterium labeled SA-d(6) and HQ-d(6) were used as internal standards (IS). The samples were extracted with methanol, dried under nitrogen and derivatized with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA)+1% trimethylchlorosilane (TMCS). Quantification was performed in SIM mode with a limit of quantification (LOQ) of 50 ng ml(-1) for SA and 10 ng ml(-1) for HQ. The inter-day variation (R.S.D.) was less than 5% and the accuracy was better than 13.3% for both compounds. The recoveries from the different matrices ranged between 93.1 and 103.3% for SA, and 97.3 and 100.8% for HQ.

  9. D{sub 2}O−H{sub 2}O solvent isotope effects on the enthalpies of bicaret hydration and dilution of its aqueous solutions at different temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, Evgeniy V., E-mail: evi@isc-ras.ru [Laboratory of Thermodynamics of Solutions of Non-electrolytes and Biologically Active Substances, G.A. Krestov Institute of Solution Chemistry, Russian Academy of Sciences, 1 Akademicheskaya Str., 153045 Ivanovo (Russian Federation); Batov, Dmitriy V. [Incorporated Physicochemical Center of Solution Researches, G.A. Krestov Institute of Solution Chemistry, Russian Academy of Sciences, 1 Akademicheskaya Str., 153045, Ivanovo (Russian Federation); Ivanovo' s State University of Chemistry and Technology, 7 Sheremetevsky Ave, 153000 Ivanovo (Russian Federation); Gazieva, Galina A.; Kravchenko, Angelina N. [Laboratory of Nitrogen-containing Compounds, N.D. Zelinsky Institute of Organic Chemistry, Russian Academy of Sciences, 47 Leninsky Ave., 199119 Moscow (Russian Federation); Abrosimov, Vladimir K. [Laboratory of Thermodynamics of Solutions of Non-electrolytes and Biologically Active Substances, G.A. Krestov Institute of Solution Chemistry, Russian Academy of Sciences, 1 Akademicheskaya Str., 153045 Ivanovo (Russian Federation)

    2014-08-20

    Graphical abstract: - Highlights: • Enthalpies of solution of bicaret (tetraethylglycoluril) in H{sub 2}O and D{sub 2}O were measured. • D{sub 2}O–H{sub 2}O enthalpy-isotopic effect is negative and decreasing with temperature. • Enthalpic coefficients h{sub 22} for pairwise solute–solute interactions were derived. • Quantity of h{sub 22} is negative and becoming the more negative in heavy water. • Prevailingly hydrophobic hydration of bicaret is weakened with rising temperature. - Abstract: The molar enthalpies of solution of bicaret or 2,4,6,8-tetraethyl-2,4,6,8-tatraazabicyclo[3.3.0]octane-3,7-dione in ordinary (H{sub 2}O) and heavy (D{sub 2}O) water at (278.15, 288.15, 298.15, 308.15, and 318.15) K as well as the enthalpies for dilution of its H/D isotopically distinguishable aqueous solutions at 298.15 K were measured calorimetrically. The standard (at infinite dilution) molar enthalpies and heat capacities of solution, and the enthalpic coefficients for pair (h{sub 22}) and triplet (h{sub 222}) interactions between hydrated solute molecules, along with D{sub 2}O–H{sub 2}O solvent isotope effects (IEs) on the studied quantities were computed. The enthalpic effects of bicaret dissolution and corresponding IEs were found to be negative and decreasing in magnitude with increasing temperature. On the contrary, the h{sub 22} and h{sub 222} values as well as IEs on them were found to be positive. These facts indicate that the bicaret hydration being predominantly hydrophobic is enhanced in the D{sub 2}O medium. The hydration behavior of the solute considered was discussed in comparison with that for mebicar or 2,4,6,8-tetramethyl-2,4,6,8-tatraazabicyclo[3.3.0]octane-3,7-dione using the previously obtained data.

  10. Cadmium determination in natural waters at the limit imposed by European legislation by isotope dilution and TiO{sub 2} solid-phase extraction

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Ruiz, Silvia; Quetel, Christophe R. [Institute for Reference Materials and Measurements, Joint Research Centre - European Commission, Geel (Belgium); Petrov, Ivan [Institute for Reference Materials and Measurements, Joint Research Centre - European Commission, Geel (Belgium); Universite Libre de Bruxelles, Department of Earth and Environmental Sciences, Brussels (Belgium); Vassileva, Emilia [Institute for Reference Materials and Measurements, Joint Research Centre - European Commission, Geel (Belgium); IAEA-Marine Environment Laboratories, Monaco (Monaco)

    2011-11-15

    The cadmium content in surface water is regulated by the last European Water Framework Directive to a maximum between 0.08 and 0.25 {mu}g L{sup -1} depending on the water type and hardness. Direct measurement of cadmium at this low level is not straightforward in real samples, and we hereby propose a validated method capable of addressing cadmium content below {mu}g L{sup -1} level in natural water. It is based on solid-phase extraction using TiO{sub 2} nanoparticles as solid sorbent (0.05 g packed in mini-columns) to allow the separation and preconcentration of cadmium from the sample, combined to direct isotope dilution and detection by inductively coupled plasma mass spectrometry (ID-ICP-MS). The extraction setup is miniaturised and semi-automated to reduce risks of sample contamination and improve reproducibility. Procedural blanks for the whole measurement process were 5.3 {+-} 2.8 ng kg{sup -1} (1 s) for 50 g of ultrapure water preconcentrated ten times. Experimental conditions influencing the separation (including loading pH, sample flow rates, and acid concentration in the eluent) were evaluated. With isotope dilution the Cd recovery rate does not have to be evaluated carefully. Moreover, the mathematical model associated to IDMS is known, and provides transparency for the uncertainty propagation. Our validation protocol was in agreement with guidelines of the ISO/IEC 17025 standard (chapter 5.4.5). Firstly, we assessed the experimental factors influencing the final result. Secondly, we compared the isotope ratios measured after our separation procedure to the reference values obtained with a different protocol for the digested test material IMEP-111 (mineral feed). Thirdly, we analysed the certified reference material BCR-609 (groundwater). Finally, combined uncertainties associated to our results were estimated according to ISO-GUM guidelines (typically, 3-4% k = 2 for a cadmium content of around 100 ng kg{sup -1}). We applied the developed method to the

  11. Speciation and reactivity of lead and zinc in heavily and poorly contaminated soils: Stable isotope dilution, chemical extraction and model views.

    Science.gov (United States)

    Ren, Zong-Ling; Sivry, Yann; Tharaud, Mickaël; Cordier, Laure; Li, Yongtao; Dai, Jun; Benedetti, Marc F

    2017-06-01

    Correct characterization of metal speciation and reactivity is a prerequisite for the risk assessment and remedial activity management of contaminated soil. To better understand the intrinsic reactivity of Pb and Zn, nine heavily and poorly contaminated soils were investigated using the combined approaches of chemical extractions, multi-element stable isotopic dilution (ID) method, and multi-surface modelling. The ID results show that 0.1-38% of total Pb and 3-45% of total Zn in the studied soils are isotopically exchangeable after a 3-day equilibration. The intercomparison between experimental and modelling results evidences that single extraction with 0.43 M HNO3 solubilizes part of non-isotopically exchangeable fraction of Pb and Zn in the studied soils, and cannot be used as a surrogate for ID to assess labile Pb and Zn pools in soil. Both selective sequential extraction (SSE) and modelling reveal that Mn oxides are the predominant sorption surface for Pb in the studied soils; while Zn is predicted to be mainly associated with soil organic matter in the soil with low pH and Fe/Mn oxides in the soils with high pH. Multi-surface modelling can provide a reasonable prediction of Pb and Zn adsorption onto different soil constituents for the most of the studied soils. The modelling could be a promising tool to decipher the underlying mechanism that controls metal reactivity in soil, but the submodel for Mn oxides should be incorporated and the model parameters, especially for the 2-pK diffuse layer model for Mn oxides, should be updated in the further studies. Copyright © 2017. Published by Elsevier Ltd.

  12. Quantification of ricin, RCA and comparison of enzymatic activity in 18 Ricinus communis cultivars by isotope dilution mass spectrometry.

    Science.gov (United States)

    Schieltz, David M; McWilliams, Lisa G; Kuklenyik, Zsuzsanna; Prezioso, Samantha M; Carter, Andrew J; Williamson, Yulanda M; McGrath, Sara C; Morse, Stephen A; Barr, John R

    2015-03-01

    The seeds of the Ricinus communis (Castor bean) plant are the source of the economically important commodity castor oil. Castor seeds also contain the proteins ricin and R. communis agglutinin (RCA), two toxic lectins that are hazardous to human health. Radial immunodiffusion (RID) and the enzyme linked immunosorbent assay (ELISA) are two antibody-based methods commonly used to quantify ricin and RCA; however, antibodies currently used in these methods cannot distinguish between ricin and RCA due to the high sequence homology of the respective proteins. In this study, a technique combining antibody-based affinity capture with liquid chromatography and multiple reaction monitoring (MRM) mass spectrometry (MS) was used to quantify the amounts of ricin and RCA independently in extracts prepared from the seeds of eighteen representative cultivars of R. communis which were propagated under identical conditions. Additionally, liquid chromatography and MRM-MS was used to determine rRNA N-glycosidase activity for each cultivar and the overall activity in these cultivars was compared to a purified ricin standard. Of the cultivars studied, the average ricin content was 9.3 mg/g seed, the average RCA content was 9.9 mg/g seed, and the enzymatic activity agreed with the activity of a purified ricin reference within 35% relative activity. Published by Elsevier Ltd.

  13. Congener-specific carbon isotopic analysis of technical PCB and PCN mixtures using two-dimensional gas chromatography-isotope ratio mass spectrometry.

    Science.gov (United States)

    Horii, Yuichi; Kannan, Kurunthachalam; Petrick, Gert; Gamo, Toshitaka; Falandysz, Jerzy; Yamashita, Nobuyoshi

    2005-06-01

    Analysis of stable carbon isotope fractionation is a useful method to study the sources and fate of anthropogenic organic contaminants such as polychlorinated biphenyls (PCBs) in the environment. To evaluate the utility of carbon isotopes, determination of isotopic ratios of 13C/12C in source materials, for example, technical PCB preparations, is needed. In this study, we determined delta13C values of 31 chlorobiphenyl (CB) congeners in 18 technical PCB preparations and 15 chloronaphthalene (CN) congeners in 6 polychlorinated naphthalene preparations using two-dimensional gas chromatography-combustion furnace-isotope ratio mass spectrometry (2DGC-C-IRMS). Development of 2DGC-IRMS enabled improved resolution and sensitivity of compound-specific carbon isotope analysis (CSIA) of CB or CN congeners. Delta13C values of PCB congeners ranged from -34.4 (Delors) to -22.0/1000 (Sovol). Analogous PCB preparations with similar chlorine content, but different geographical origin, had different delta13C values. PCB preparations from Eastern European countries--Delors, Sovol, Trichlorodiphenyl, and Chlorofen--had distinct delta13C values. PCB mixtures showed increased 13C depletion with increasing chlorine content. Delta13C values for individual CB congeners varied depending on the degree of chlorination in technical mixtures. Delta13C values of CN congeners in Halowaxes ranged from -26.3 to -21.7/1000 and these values are within the ranges observed for PCBs. This study establishes the range of delta13C values in technical PCB and PCN preparations, which may prove to be useful in the determination of sources of these compounds in the environment. This is the first study to employ 2DGC-IRMS analysis of delta13C values in technical PCB and PCN preparations.

  14. Simple and sensitive analysis of histamine and tyramine in Japanese soy sauces and their intermediates using the stable isotope dilution HILIC-MS/MS method.

    Science.gov (United States)

    Todoroki, Kenichiro; Ishii, Yasuhiro; Miyauchi, Chiemi; Kitagawa, Sachiyo; Min, Jun Zhe; Inoue, Koichi; Yamanaka, Tomoyuki; Suzuki, Kuniaki; Yoshikawa, Yuko; Ohashi, Norio; Toyo'oka, Toshimasa

    2014-07-02

    We established a simple, sensitive, and reproducible method to analyze the histamine and tyramine levels in Japanese soy sauce and its mash (called moromi) using hydrophilic interaction liquid chromatography with tandem mass spectrometry (HILIC-MS/MS). Histamine and tyramine quantification was performed using their stable isotopes for electrospray ionization-tandem mass spectrometry in the selected reaction monitoring mode. The sample pretreatment process was a simple, one-step liquid-liquid extraction. HILIC separation was performed with a gradient elution of aqueous ammonium formate and acetonitrile. Because of validation tests, the linearity, the accuracies, and precisions were sufficient. The limit of detection and the limit of quantification were 0.09 and 0.29 ppm for histamine and 0.13 and 0.42 ppm for tyramine, respectively. We successfully applied this method to histamine and tyramine determination in four kinds of commercial Japanese soy sauces and also in moromi samples during soy sauce production.

  15. Physicochemical characterization of D-mannitol polymorphs: the challenging surface energy determination by inverse gas chromatography in the infinite dilution region.

    Science.gov (United States)

    Cares-Pacheco, M G; Vaca-Medina, G; Calvet, R; Espitalier, F; Letourneau, J-J; Rouilly, A; Rodier, E

    2014-11-20

    Nowadays, it is well known that surface interactions play a preponderant role in mechanical operations, which are fundamental in pharmaceutical processing and formulation. Nevertheless, it is difficult to correlate surface behaviour in processes to physical properties measurement. Indeed, most pharmaceutical solids have multiple surface energies because of varying forms, crystal faces and impurities contents or physical defects, among others. In this paper, D-mannitol polymorphs (α, β and δ) were studied through different characterization techniques highlighting bulk and surface behaviour differences. Due to the low adsorption behaviour of β and δ polymorphs, special emphasis has been paid to surface energy analysis by inverse gas chromatography, IGC. Surface energy behaviour has been studied in Henry's domain showing that, for some organic solids, the classical IGC infinite dilution zone is never reached. IGC studies highlighted, without precedent in literature, dispersive surface energy differences between α and β mannitol, with a most energetically active α form with a γ(s)(d) of 74.9 mJ·m⁻². Surface heterogeneity studies showed a highly heterogeneous α mannitol with a more homogeneous β (40.0 mJ·m⁻²) and δ mannitol (40.3 mJ·m⁻²). Moreover, these last two forms behaved similarly considering surface energy at different probe concentrations.

  16. Amino acid δ13C analysis of hair proteins and bone collagen using liquid chromatography/isotope ratio mass spectrometry

    DEFF Research Database (Denmark)

    Raghavan, Maanasa; McCullagh, James S. O.; Lynnerup, Niels

    2010-01-01

    We report a novel method for the chromatographic separation and measurement of stable carbon isotope ratios (delta(13)C) of individual amino acids in hair proteins and bone collagen using the LC-IsoLink system, which interfaces liquid chromatography (LC) with isotope ratio mass spectrometry (IRMS......). This paper provides baseline separation of 15 and 13 of the 18 amino acids in bone collagen and hair proteins, respectively. We also describe an approach to analysing small hair samples for compound-specific analysis of segmental hair sections. The LC/IRMS method is applied in a historical context...... by the delta(13)C analysis of hair proteins and bone collagen recovered from six individuals from Uummannaq in Greenland. The analysis of hair and bone amino acids from the same individual, compared for the first time in this study, is of importance in palaeodietary reconstruction. If hair proteins can be used...

  17. Using Gas Chromatography/Isotope Ratio Mass Spectrometry to Determine the Fractionation Factor for H2 Production by Hydrogenases

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Hui; Ghandi, H.; Shi, Liang; Kreuzer, Helen W.; Ostrom, Nathaniel; Hegg, Eric L.

    2012-01-15

    Hydrogenases catalyze the reversible formation of H2, and they are key enzymes in the biological cycling of H2. H isotopes should be a very useful tool in quantifying proton trafficking in biological H2 production processes, but there are several obstacles that have thus far limited the use of this tool. In this manuscript, we describe a new method that overcomes some of these barriers and is specifically designed to measure isotopic fractionation during enzyme-catalyzed H2 evolution. A key feature of this technique is that purified hydrogenases are employed, allowing precise control over the reaction conditions and therefore a high level of precision. A custom-designed high-throughput gas chromatography-isotope ratio mass spectrometer is employed to measure the isotope ratio of the H2. Using this method, we determined that the fractionation factor of H2 production by the [NiFe]-hydrogenase from Desulfivibrio fructosovran is 0.27. This result indicates that, as expected, protons are highly favored over deuterons during H2 evolution. Potential applications of this new method are discussed.

  18. Application of isotope-dilution laser ablation ICP-MS for direct determination of Pu concentrations in soils at pg g(-1) levels.

    Science.gov (United States)

    Boulyga, Sergei F; Tibi, Markus; Heumann, Klaus G

    2004-01-01

    The methods available for determination of environmental contamination by plutonium at ultra-trace levels require labor-consuming sample preparation including matrix removal and plutonium extraction in both nuclear spectroscopy and mass spectrometry. In this work, laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was applied for direct analysis of Pu in soil and sediment samples. Application of a LINA-Spark-Atomizer system (a modified laser ablation system providing high ablation rates) coupled with a sector-field ICP-MS resulted in detection limits as low as 3x10(-13) g g(-1) for Pu isotopes in soil samples containing uranium at a concentration of a few microg g(-1). The isotope dilution (ID) technique was used for quantification, which compensated for matrix effects in LA-ICP-MS. Interferences by UH+ and PbO2+ ions and by the peak tail of 238U+ ions were reduced or separated by use of dry plasma conditions and a mass resolution of 4000, respectively. No other effects affecting measurement accuracy, except sample inhomogeneity, were revealed. Comparison of results obtained for three contaminated soil samples by use of alpha-spectrometry, ICP-MS with sample decomposition, and LA-ICP-IDMS showed, in general, satisfactory agreement of the different methods. The specific activity of (239+240)Pu (9.8 +/- 3.0 mBq g(-1)) calculated from LA-ICP-IDMS analysis of SRM NIST 4357 coincided well with the certified value of 10.4 +/- 0.2 mBq g(-1). However, the precision of LA-ICP-MS for determination of plutonium in inhomogeneous samples, i.e. if "hot" particles are present, is limited. As far as we are aware this paper reports the lowest detection limits and element concentrations yet measured in direct LA-ICP-MS analysis of environmental samples.

  19. Vitamin A equivalency of beta-carotene in healthy adults: limitation of the extrinsic dual-isotope dilution technique to measure matrix effect.

    Science.gov (United States)

    Van Loo-Bouwman, Carolien A; West, Clive E; van Breemen, Richard B; Zhu, Dongwei; Siebelink, Els; Versloot, Pieter; Hulshof, Paul J M; van Lieshout, Machteld; Russel, Frans G M; Schaafsma, Gertjan; Naber, Ton H J

    2009-06-01

    Data on the vitamin A equivalency of beta-carotene in food are inconsistent. We quantified the vitamin A equivalency (microg) of beta-carotene in two diets using the dual-isotope dilution technique and the oral-faecal balance technique. A diet-controlled, cross-over intervention study was conducted in twenty-four healthy adults. Each subject followed two diets for 3 weeks each: a diet containing vegetables low in beta-carotene with supplemental beta-carotene in salad dressing oil ('oil diet') and a diet containing vegetables and fruits high in beta-carotene ('mixed diet'). During all 6 weeks, each subject daily consumed a mean of 55 (sd 0.5) microg [13C10]beta-carotene and 55 (sd 0.5) microg [13C10]retinyl palmitate in oil capsules. The vitamin A equivalency of beta-carotene was calculated as the dose-corrected ratio of [13C5]retinol to [13C10]retinol in serum and from apparent absorption by oral-faecal balance. Isotopic data quantified a vitamin A equivalency of [13C10]beta-carotene in oil of 3.4 microg (95 % CI 2.8, 3.9), thus the bio-efficacy of the beta-carotene in oil was 28 % in the presence of both diets. However, data from oral-faecal balance estimated vitamin A equivalency as 6:1 microg (95 % CI 4, 7) for beta-carotene in the 'oil diet'. beta-Carotene in the 'oil diet' had 2.9-fold higher vitamin A equivalency than beta-carotene in the 'mixed diet'. In conclusion, this extrinsic labelling technique cannot measure effects of mixed vegetables and fruits matrices, but can measure precisely the vitamin A equivalency of the beta-carotene in oil capsules.

  20. Body composition in Nepalese children using isotope dilution: the production of ethnic-specific calibration equations and an exploration of methodological issues

    Directory of Open Access Journals (Sweden)

    Delan Devakumar

    2015-03-01

    Full Text Available Background. Body composition is important as a marker of both current and future health. Bioelectrical impedance (BIA is a simple and accurate method for estimating body composition, but requires population-specific calibration equations.Objectives. (1 To generate population specific calibration equations to predict lean mass (LM from BIA in Nepalese children aged 7–9 years. (2 To explore methodological changes that may extend the range and improve accuracy.Methods. BIA measurements were obtained from 102 Nepalese children (52 girls using the Tanita BC-418. Isotope dilution with deuterium oxide was used to measure total body water and to estimate LM. Prediction equations for estimating LM from BIA data were developed using linear regression, and estimates were compared with those obtained from the Tanita system. We assessed the effects of flexing the arms of children to extend the range of coverage towards lower weights. We also estimated potential error if the number of children included in the study was reduced.Findings. Prediction equations were generated, incorporating height, impedance index, weight and sex as predictors (R2 93%. The Tanita system tended to under-estimate LM, with a mean error of 2.2%, but extending up to 25.8%. Flexing the arms to 90° increased the lower weight range, but produced a small error that was not significant when applied to children <16 kg (p 0.42. Reducing the number of children increased the error at the tails of the weight distribution.Conclusions. Population-specific isotope calibration of BIA for Nepalese children has high accuracy. Arm position is important and can be used to extend the range of low weight covered. Smaller samples reduce resource requirements, but leads to large errors at the tails of the weight distribution.

  1. Headspace-solid phase microextraction coupled to gas chromatography-combustion-isotope ratio mass spectrometer and to enantioselective gas chromatography for strawberry flavoured food quality control.

    Science.gov (United States)

    Schipilliti, Luisa; Dugo, Paola; Bonaccorsi, Ivana; Mondello, Luigi

    2011-10-21

    Authenticity assessment of flavoured strawberry foods was performed using headspace-solid phase microextraction (HS-SPME) coupled to gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS). An authenticity range was achieved, investigating on the carbon isotope ratio of numerous selected aroma active volatile components (methyl butanoate, ethyl butanoate, hex-(2E)-enal, methyl hexanoate, buthyl butanoate, ethyl hexanoate, hexyl acetate, linalool, hexyl butanoate, octyl isovalerate, γ-decalactone and octyl hexanoate) of organic Italian fresh strawberries. To the author's knowledge, this is the first time that all these components were investigated simultaneously by GC-C-IRMS on the same sample. The results were compared, when applicable, with those obtained by analyzing the HS-SPME extracts of commercial flavoured food matrices. In addition, one Kenyan pineapple and one fresh Italian peach were analyzed to determine the δ(13)C(VPDB) of the volatile components common to strawberry. The δ(13)C(VPDB) values are allowed to differentiate between different biogenetic pathways (C(3) and CAM plants) and more interestingly between plants of the same CO(2) fixation group (C(3) plants). Additional analyses were performed on all the samples by means of Enantioselective Gas Chromatography (Es-GC), measuring the enantiomeric distribution of linalool and γ-decalactone. It was found that GC-C-IRMS and Es-GC measurements were in agreement to detect the presence of non-natural strawberry aromas in the food matrices studied. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Development of a routine analysis of 4-mercapto-4-methylpentan-2-one in wine by stable isotope dilution assay and mass tandem spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dagan, Laurent; Reillon, Florence; Roland, Aurélie; Schneider, Rémi, E-mail: remi@nyseos.fr

    2014-04-01

    Highlights: • We proposed a routine method to analyze the 4-methyl-4-mercaptopentan-2-one in wine. • We developed the first method with sensitivity below the 4MMP perception threshold. • We obtained an accurate method by using the stable isotope dilution assay approach. Abstract: The 4-mercapto-4-methylpentan-2-one (4MMP) is a key aroma compound in wines, especially in Sauvignon Blanc ones. Its accurate quantification is quite difficult due to its traces levels and its reactivity in wine conferred by the thiol function. In this paper, we proposed a new method for its quantification in wine without any sample preparation, based on automated derivatization procedure by methoximation and SIDA–SPME–GC–MS/MS analysis. The derivatization procedure was adapted from a previously published method in order to decrease the amount of reagents and the volume of wine (only 3 mL are required). The use of SPME and the detection conditions have also been optimized to reach the best sensitivity as possible. The method was then validated according to the International Organization of Vine and Wine recommendations and exhibited excellent performances. Indeed, this method allowed us to quantify the 4MMP in wine at traces levels (LOD = 0.19 ng L₅⁻¹) with reproducible results (RSD < 15%) and a very good accuracy (recovery = 102%)

  3. Solid sampling electrothermal vaporization inductively coupled plasma mass spectrometry for the direct determination of Hg in different materials using isotope dilution with a gaseous phase for calibration

    Science.gov (United States)

    Resano, M.; Gelaude, I.; Dams, R.; Vanhaecke, F.

    2005-03-01

    This paper evaluates the potential of electrothermal vaporization-inductively coupled plasma mass spectrometry (ETV-ICPMS) for the direct determination of Hg in solid samples, using a 200Hg-enriched gaseous phase for calibration based on isotope dilution. Three different samples were studied, BCR CRM 320 River sediment, IAEA-086 Hair and a real (wet) freshwater fish sample (M1). The samples selected show important differences in their matrix composition, and especially the fish sample constitutes a challenge as a result of its high water content (≈80%). The main conclusion of the work is that the calibration approach investigated succesfully corrects for all the matrix effects (suppression) observed during Hg vaporization, allowing accurate values to be obtained in all cases. Moreover, practically the same operating conditions could be used for all sample types. The method finally proposed presents interesting features for the direct determination of this challenging element in solid samples, such as: a low sample consumption (a few milligrams), a high sample throughput (10 min/sample), a low limit of detection (6 ng g -1) and a reduced risk of analyte losses or contamination. Precision values depend on the homogeneity of the sample studied, and are typically in the vicinity of 10% RSD, except for the more inhomogenous river sediment (18% RSD).

  4. Evaluation of the key aroma compounds in beef and pork vegetable gravies a la chef by stable isotope dilution assays and aroma recombination experiments.

    Science.gov (United States)

    Christlbauer, Monika; Schieberle, Peter

    2011-12-28

    Although the aroma compounds of meat processed as such have been studied previously, data on complete homemade dishes containing beef and pork meat were scarcely studied. Recently, 38 odor-active compounds were characterized in beef and pork vegetable gravies using GC-olfactometry. In the present investigation, the most odor-active compounds were quantitated in a freshly prepared stewed beef vegetable gravy (BVG) as well as a stewed pork vegetable gravy (PVG) by means of stable isotope dilution assays. Calculation of odor activity values (OAVs; ratio of concentration to odor threshold) revealed 3-mercapto-2-methylpentan-1-ol, (E,E)-2,4-decadienal, (E,Z)-2,6-nonadienal, (E)-2-decenal, (E)-2-undecanal, and 3-hydroxy-4,5-dimethyl-2(5H)-furanone as the most potent odorants in both gravies. However, significantly different OAVs were found for 12-methyltridecanal, which was much higher in the BVG, whereas (E,Z)-2,4-decadienal showed a clearly higher OAV in the PVG. Aroma recombination experiments performed on the basis of the actual concentrations of the odorants in both gravies revealed a good similarity of the aromas of both model mixtures containing all odorants with OAVs > 1 with those of the original gravies.

  5. Measurement of 2-carboxyarabinitol 1-phosphate in plant leaves by isotope dilution. [Spinacea oleracea; Triticum aestivum; Arabidopsis thaliana; Maize; Phaseolus vulgaris; Petunia hybrida

    Energy Technology Data Exchange (ETDEWEB)

    Moore, B.D.; Kobza, J.; Seemann, J.R. (Univ. of Nevada, Reno (United States))

    1991-05-01

    The level of 2-carboxyarabinitol 1-phosphate (CA1P) in leaves of 12 species was determined by an isotope dilution assay. {sup 14}C-labeled standard was synthesized from (2-{sup 14}C)carboxyarabinitol 1,5-bisphosphate using acid phosphatase, and was added at the initial point of leaf extraction. Leaf CA1P was purified and its specific activity determined. CA1P was found in dark-treated leaves of all species examined, including spinach (Spinacea oleracea), wheat (Triticum aestivum), Arabidopsis thaliana, and maize (Zea mays). The highest amounts were found in bean (Phaseolus vulgaris) and petunia (Petunia hybrida), which had 1.5 to 1.8 moles CA1P per mole ribulose 1,5-bisphosphate carboxylase catalytic sites. Most species had intermediate amounts of CA1P (0.2 to 0.8 mole CA1P per mole catalytic sites). Such intermediate to high levels of CA1P support the hypothesis that CA1P functions in many species as a light-dependent regulator of ribulose 1,5-bisphosphate carboxylase activity and whole leaf photosynthetic CO{sub 2} assimilation. However, CA1P levels in spinach, wheat, and A. thaliana were particularly low (less than 0.09 mole CA1P per mole catalytic sites). In such species, CA1P does not likely have a significant role in regulating ribulose 1,5-bisphosphate carboxylase activity, but could have a different physiological role.

  6. Effects of Conventional Heating on the Stability of Major Olive Oil Phenolic Compounds by Tandem Mass Spectrometry and Isotope Dilution Assay

    Directory of Open Access Journals (Sweden)

    Giovanni Sindona

    2010-12-01

    Full Text Available The quality of olive oils is sensorially tested by accurate and well established methods. It enables the classification of the pressed oils into the classes of extra virgin oil, virgin oil and lampant oil. Nonetheless, it would be convenient to have analytical methods for screening oils or supporting sensorial analysis using a reliable independent approach based on exploitation of mass spectrometric methodologies. A number of methods have been proposed to evaluate deficiencies of extra virgin olive oils resulting from inappropriate technological treatments, such as high or low temperature deodoration, and home cooking processes. The quality and nutraceutical value of extra virgin olive oil (EVOO can be related to the antioxidant property of its phenolic compounds. Olive oil is a source of at least 30 phenolic compounds, such as oleuropein, oleocanthal, hydroxytyrosol, and tyrosol, all acting as strong antioxidants, radical scavengers and NSAI-like drugs. We now report the efficacy of MRM tandem mass spectrometry, assisted by the isotope dilution assay, in the evaluation of the thermal stability of selected active principles of extra virgin olive oil.

  7. Determination of urinary cortisol, cortisone and 6-sulfatoxymelatonin using dilute and shoot ultra-high pressure liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Sniecinska-Cooper, Anna Maria; Shah, Ajit Jesang; Dimitriou, Dagmara; Iles, Ray Kruse; Butler, Stephen Andrew; Bayford, Richard

    2015-01-26

    Human sleep is a natural part of every individual's life. Clear relationship between sleep and endocrine system has been already established. In particular, melatonin and cortisol are known to affect and regulate sleep/wake patterns. Here we report the development of an ultra-high pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous measurement of 6-sulfatoxymelatonin (MT6s), cortisol and cortisone in urine. A separate method was developed for measurement of creatinine in urine. These levels were used to normalise the levels of analytes. First void morning urine samples were collected from 24 healthy volunteers. Samples were diluted 1:1 in water prior to injection onto reversed-phase C18 column and analysed using UHPLC-MS/MS method. Linear calibrations were obtained for all analytes with correlation coefficient in the range 0.998-0.999. The observed concentration was found to be in the range 92-105% for cortisol, 92-107% for cortisone and between 93 and 120% for MT6s of the reference levels. The total run time of 6 min with all peaks of interest eluting within 3 min was obtained. This demonstrates the feasibility of utilising the method for large multi-scale studies, where high throughput is required for studying the circadian rhythm of melatonin and cortisol secretion. These hormones play significant role in circadian rhythm and sleep/wake cycle; therefore it is important to monitor the levels of these endocrine markers in individuals suffering from sleep disorders. It is also beneficial with clinical applications to analyse melatonin and cortisol simultaneously in order to assess their interrelationships of these substances, such as their effect on diurnal rhythm and sleep. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Determination of the natural abundance δ15N of taurine by gas chromatography-isotope ratio measurement mass spectrometry.

    Science.gov (United States)

    Tea, Illa; Antheaume, Ingrid; Besnard, Jorick; Robins, Richard J

    2010-12-15

    The measurement of the nitrogen isotope ratio of taurine (2-aminoethanesulphonic acid) in biological samples has a large number of potential applications. Taurine is a small water-soluble molecule which is notoriously difficult to analyze due to its polarity and functionality. A method is described which allows the determination of the natural abundance δ(15)N values of taurine and structural analogues, such as 3-amino-1-propanesulphonic acid (APSA), by isotope ratio mass spectrometry interfaced to gas chromatography (GC-irm-MS). The one-step protocol exploits the simultaneous derivatization of both functionalities of these aminosulphonic acids by reaction with triethylorthoacetate (TEOA). Conditions have been established which ensure quantitative reaction thus avoiding any nitrogen isotope fractionation during derivatization and workup. The differences in the δ(15)N values of derivatized and non-derivatized taurine and APSA all fall within the working range of 0.4‰ (-0.02 to 0.39‰). When applied to four sources of taurine with various δ(15)N values, the method achieved excellent reproducibility and accuracy. The optimized method enables the determination of the natural abundance δ(15)N values of taurine over the concentration range 1.5-7.84 µmol.mL(-1) in samples of biological origin.

  9. Isotope Fractionation of chlorine in Aqueous System: One Study on Anion-Exchange Chromatography.

    Science.gov (United States)

    Musashi, M.; Oi, T.; Eggenkamp, H.; Van Cappellen, P.

    2001-05-01

    Stable chlorine isotopes such as 37Cl and 35Cl have been paid attention as useful tool identifying the source, and monitoring the transport process and natural fate of chlorinated organic pollutants in air and groundwater. However, it is not established yet whether any isotope effects accompany biodegradation or reductive dehalogenation of the pollutants (Clark and Fritz, 1997). Here we first present an experimental determination of isotope fractionation factor of chlorine in aqueous system by using anion-exchange chromatographic technique. Into the Cl-free anion exchange resin (Muromac, OH- form) packed in a 30 cm long pyrex glass column and controlled temperature at 25 oC, hydrochloric solution was fed with controlling the flow rate constant. Effluent from the column was recovered by an automatic fraction collector and prepared for Cl isotope analysis. The Cl isotope ratio (δ 37Cl vs. SMOC) was measured by IR-MS at the Utrecht University with precision of 0.06 per-mil. Magnitude of the factor obtained was 1.00035 at 25 oC. The result indicates that the lighter isotope (35Cl) was preferably fractionated into the resin phase, while the heavier one (37Cl) was enriched into the aqueous phase. This trend suggests that molecular structure of hydrolysis with Cl in aqueous phase may be more stable than that of Cl ionically bonding with the resin. This result may offer physico-chemical insights into behavior and fate of the pollutants.

  10. Potential of ion chromatography coupled to isotope ratio mass spectrometry via a liquid interface for beverages authentication.

    Science.gov (United States)

    Guyon, Francois; Gaillard, Laetitia; Brault, Audrey; Gaultier, Nicolas; Salagoïty, Marie-Hélène; Médina, Bernard

    2013-12-27

    New tools for the determination of characteristic parameters for food authentication are requested to prevent food adulteration from which health concerns, unfair competition could follow. A new coupling in the area of compound-specific carbon 13 isotope ratio (δ(13)C) analysis was developed to simultaneously quantify δ(13)C values of sugars and organic acids. The coupling of ion chromatography (IC) together with isotope ratio mass spectrometry (IRMS) can be achieved using a liquid interface allowing a chemical oxidation (co) of organic matter. Synthetic solutions containing 1 polyol (glycerol), 3 carbohydrates (sucrose, glucose and fructose) and 12 organic acids (gluconic, lactic, malic, tartaric, oxalic, fumaric, citric and isocitric) were used to optimize chromatographic conditions (concentration gradient and 3 types of column) and the studied isotopic range (-32.28 to -10.65‰) corresponds to the values found in food products. Optimum chromatographic conditions are found using an IonPac AS15, an elution flow rate of 0.3mLmin(-1) and a linear concentration gradient from 2 to 76mM (rate 21mMmin(-1)). Comparison between δ(13)C value individually obtained for each compound with the coupling IRMS and elemental analyzer, EA-IRMS, and the ones measured on the mixture of compounds by IC-co-IRMS does not reveal any isotope fractionation. Thus, under these experimental conditions, IC-co-IRMS results are accurate and reproducible. This new coupling was tested on two food matrices, an orange juice and a sweet wine. Some optimization is necessary as the concentration range between sugars and organic acids is too large: an increase in the filament intensity of the IRMS is necessary to simultaneously detect the two compound families. These first attempts confirm the good results obtained on synthetic solutions and the strong potential of the coupling IC-co-IRMS in food authentication area.

  11. Doping control analysis of 46 polar drugs in horse plasma and urine using a 'dilute-and-shoot' ultra high performance liquid chromatography-high resolution mass spectrometry approach.

    Science.gov (United States)

    Kwok, Wai Him; Choi, Timmy L S; Kwok, Karen Y; Chan, George H M; Wong, Jenny K Y; Wan, Terence S M

    2016-06-17

    The high sensitivity of ultra high performance liquid chromatography coupled with high resolution mass spectrometry (UHPLC-HRMS) allows the identification of many prohibited substances without pre-concentration, leading to the development of simple and fast 'dilute-and-shoot' methods for doping control for human and equine sports. While the detection of polar drugs in plasma and urine is difficult using liquid-liquid or solid-phase extraction as these substances are poorly extracted, the 'dilute-and-shoot' approach is plausible. This paper describes a 'dilute-and-shoot' UHPLC-HRMS screening method to detect 46 polar drugs in equine urine and plasma, including some angiotensin-converting enzyme (ACE) inhibitors, sympathomimetics, anti-epileptics, hemostatics, the new doping agent 5-aminoimidazole-4-carboxamide-1-β-d-ribofuranoside (AICAR), as well as two threshold substances, namely dimethyl sulfoxide and theobromine. For plasma, the sample (200μL) was protein precipitated using trichloroacetic acid, and the resulting supernatant was diluted using Buffer A with an overall dilution factor of 3. For urine, the sample (20μL) was simply diluted 50-fold with Buffer A. The diluted plasma or urine sample was then analysed using a UHPLC-HRMS system in full-scan ESI mode. The assay was validated for qualitative identification purpose. This straightforward and reliable approach carried out in combination with other screening procedures has increased the efficiency of doping control analysis in the laboratory. Moreover, since the UHPLC-HRMS data were acquired in full-scan mode, the method could theoretically accommodate an unlimited number of existing and new doping agents, and would allow a retrospectively search for drugs that have not been targeted at the time of analysis.

  12. Application of isotope-dilution laser ablation ICP-MS for direct determination of Pu concentrations in soils at pg g{sup -1} levels

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, Sergei F.; Tibi, Markus; Heumann, Klaus G. [Institute of Inorganic Chemistry and Analytical Chemistry, Johannes Gutenberg-University Mainz, Duesbergweg 10-14, 55099, Mainz (Germany)

    2004-01-01

    The methods available for determination of environmental contamination by plutonium at ultra-trace levels require labor-consuming sample preparation including matrix removal and plutonium extraction in both nuclear spectroscopy and mass spectrometry. In this work, laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was applied for direct analysis of Pu in soil and sediment samples. Application of a LINA-Spark-Atomizer system (a modified laser ablation system providing high ablation rates) coupled with a sector-field ICP-MS resulted in detection limits as low as 3 x 10{sup -13} g g{sup -1} for Pu isotopes in soil samples containing uranium at a concentration of a few {mu}g g{sup -1}. The isotope dilution (ID) technique was used for quantification, which compensated for matrix effects in LA-ICP-MS. Interferences by UH{sup +} and PbO{sub 2}{sup +} ions and by the peak tail of {sup 238}U{sup +} ions were reduced or separated by use of dry plasma conditions and a mass resolution of 4000, respectively. No other effects affecting measurement accuracy, except sample inhomogeneity, were revealed. Comparison of results obtained for three contaminated soil samples by use of {alpha}-spectrometry, ICP-MS with sample decomposition, and LA-ICP-IDMS showed, in general, satisfactory agreement of the different methods. The specific activity of {sup 239+240}Pu (9.8{+-}3.0 mBq g{sup -1}) calculated from LA-ICP-IDMS analysis of SRM NIST 4357 coincided well with the certified value of 10.4{+-}0.2 mBq g{sup -1}. However, the precision of LA-ICP-MS for determination of plutonium in inhomogeneous samples, i.e. if ''hot'' particles are present, is limited. As far as we are aware this paper reports the lowest detection limits and element concentrations yet measured in direct LA-ICP-MS analysis of environmental samples. (orig.)

  13. Development of three stable isotope dilution assays for the quantitation of (E)-2-butenal (crotonaldehyde) in heat-processed edible fats and oils as well as in food.

    Science.gov (United States)

    Granvogl, Michael

    2014-02-12

    Three stable isotope dilution assays (SIDAs) were developed for the quantitation of (E)-2-butenal (crotonaldehyde) in heat-processed edible fats and oils as well as in food using synthesized [¹³C₄]-crotonaldehyde as internal standard. First, a direct headspace GC-MS method, followed by two indirect methods on the basis of derivatization with either pentafluorophenylhydrazine (GC-MS) or 2,4-dinitrophenylhydrazine (LC-MS/MS), was developed. All methods are also suitable for the quantitation of acrolein using the standard [¹³C₃]-acrolein. Applying these three methods on five different types of fats and oils varying in their fatty acid compositions revealed significantly varying crotonaldehyde concentrations for the different samples, but nearly identical quantitative data for all methods. Formed amounts of crotonaldehyde were dependent not only on the type of oil, e.g., 0.29-0.32 mg/kg of coconut oil or 33.9-34.4 mg/kg of linseed oil after heat-processing for 24 h at 180 °C, but also on the applied temperature and time. The results indicated that the concentration of formed crotonaldehyde seemed to be correlated with the amount of linolenic acid in the oils. Furthermore, the formation of crotonaldehyde was compared to that of its homologue acrolein, demonstrating that acrolein was always present in higher amounts in heat-processed oils, e.g., 12.3 mg of crotonaldehyde/kg of rapeseed oil in comparison to 23.4 mg of acrolein/kg after 24 h at 180 °C. Finally, crotonaldehyde was also quantitated in fried food, revealing concentrations from 12 to 25 μg/kg for potato chips and from 8 to 19 μg/kg for donuts, depending on the oil used.

  14. Studies on the analysis of 25-hydroxyvitamin D{sub 3} by isotope-dilution liquid chromatography–tandem mass spectrometry using enzyme-assisted derivatisation

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Khalik, Jonas, E-mail: J.A.F.A.ABDEL-KHALIK.744116@swansea.ac.uk [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom); Crick, Peter J. [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom); Carter, Graham D. [DEQAS, Imperial College Healthcare NHS Trust, Clinical Biochemistry Department, Charing Cross Hospital, Fulham Palace Rd, London W6 8RF (United Kingdom); Makin, Hugh L. [Barts and the Royal London School of Medicine and Dentistry, Queen Mary University of London, London E1 2AD (United Kingdom); Wang, Yuqin [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom); Griffiths, William J., E-mail: w.j.griffiths@swansea.ac.uk [Institute of Mass Spectrometry, College of Medicine, Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom)

    2014-04-11

    Highlights: • New method for the analysis of 25-hydroxyvitamin D{sub 3} exploiting Girard P derivatisation. • Method also applicable to vitamin D{sub 3}, 1α,25- and 24,25-dihydroxyvitamin D{sub 3}. • By modification of the method 3-epi-25-hydroxyvitamin D{sub 3} can also be analysed. - Abstract: The total serum concentration of 25-hydroxyvitamins D (25-hydroxyvitamin D{sub 3} and 25-hydroxyvitamin D{sub 2}) is currently used as an indicator of vitamins D status. Vitamins D insufficiency is claimed to be associated with multiple diseases, thus accurate and precise reference methods for the quantification of 25-hydroxyvitamins D are needed. Here we present a novel enzyme-assisted derivatisation method for the analysis of vitamins D metabolites in adult serum utilising 25-[26,26,26,27,27,27-{sup 2}H{sub 6}]hydroxyvitamin D{sub 3} as the internal standard. Extraction of 25-hydroxyvitamins D from serum is performed with acetonitrile, which is shown to be more efficient than ethanol. Cholesterol oxidase is used to oxidize the 3β-hydroxy group in the vitamins D metabolites followed by derivatisation of the newly formed 3-oxo group with Girard P reagent. 17β-Hydroxysteroid dehydrogenase type 10 is shown to oxidize selectively the 3α-hydroxy group in the 3α-hydroxy epimer of 25-hydroxyvitamin D{sub 3}. Quantification is achieved by isotope-dilution liquid chromatography–tandem mass spectrometry. Recovery experiments for 25-hydroxyvitamin D{sub 3} performed on adult human serum give recovery of 102–106%. Furthermore in addition to 25-hydroxyvitamin D{sub 3}, 24,25-dihydroxyvitamin D{sub 3} and other uncharacterised dihydroxy metabolites, were detected in adult human serum.

  15. Precise determination of the Alternaria mycotoxins alternariol and alternariol monomethyl ether in cereal, fruit and vegetable products using stable isotope dilution assays.

    Science.gov (United States)

    Asam, Stefan; Konitzer, Katharina; Rychlik, Michael

    2011-02-01

    Cereal, fruit and vegetable products were analyzed for contamination with the Alternaria mycotoxins alternariol (AOH) and alternariol monomethyl ether (AME) using stable isotope dilution assays (SIDAs). Both toxins were practically not detected in cereals and cereal products: AOH-one out of 13 samples at a content of 4.1 μg/kg; AME-two out of 13 samples at contents ranging between 0.2 and 0.6 μg/kg. However, if cereals for animal nutrition were analyzed, much higher values were found: AOH-five out of six samples (13-250 μg/kg); AME-six out of six samples (3-100 μg/kg). This finding may pose a potential problem concerning animal health. AOH and AME were frequently detected in vegetable products: AOH-5 out of 10 samples (2.6-25 μg/kg); AME-6 out of 10 samples (0.1-5 μg/kg). Tomato products were affected, especially. The highest content of AOH (25 μg/kg) and AME (5 μg/kg) were found in triple concentrated tomato paste. Special wines like "Trockenbeerenauslese" or "Spätlese" (affected by noble rot in the vineyard) contained AOH (4/6 samples; 1.2-4.9 μg/kg) and AME (4/6 samples; 0.1-0.3 μg/kg), but the values did not exceed the values of both toxins that were found generally in wines.

  16. Simple and rapid analytical method for detection of amino acids in blood using blood spot on filter paper, fast-GC/MS and isotope dilution technique.

    Science.gov (United States)

    Kawana, Shuichi; Nakagawa, Katsuhiro; Hasegawa, Yuki; Yamaguchi, Seiji

    2010-11-15

    A simple and rapid method for quantitative analysis of amino acids, including valine (Val), leucine (Leu), isoleucine (Ile), methionine (Met) and phenylalanine (Phe), in whole blood has been developed using GC/MS. In this method, whole blood was collected using a filter paper technique, and a 1/8 in. blood spot punch was used for sample preparation. Amino acids were extracted from the sample, and the extracts were purified using cation-exchange resins. The isotope dilution method using ²H₈-Val, ²H₃-Leu, ²H₃-Met and ²H₅-Phe as internal standards was applied. Following propyl chloroformate derivatization, the derivatives were analyzed using fast-GC/MS. The extraction recoveries using these techniques ranged from 69.8% to 87.9%, and analysis time for each sample was approximately 26 min. Calibration curves at concentrations from 0.0 to 1666.7 μmol/l for Val, Leu, Ile and Phe and from 0.0 to 333.3 μmol/l for Met showed good linearity with regression coefficients=1. The method detection limits for Val, Leu, Ile, Met and Phe were 24.2, 16.7, 8.7, 1.5 and 12.9 μmol/l, respectively. This method was applied to blood spot samples obtained from patients with phenylketonuria (PKU), maple syrup urine disease (MSUD), hypermethionine and neonatal intrahepatic cholestasis caused by citrin deficiency (NICCD), and the analysis results showed that the concentrations of amino acids that characterize these diseases were increased. These results indicate that this method provides a simple and rapid procedure for precise determination of amino acids in whole blood. Copyright © 2010 Elsevier B.V. All rights reserved.

  17. Determination of low isotopic enrichment of L-[1-C-13]valine by gas chromatography combustion isotope ratio mass spectrometry : a robust method for measuring protein fractional synthetic rates in vivo

    NARCIS (Netherlands)

    Reijngoud, DJ; Hellstern, G; Elzinga, H; de Sain-van der Velden, MG; Okken, A; Stellaard, F

    1998-01-01

    A method was developed for measuring protein fractional synthetic rates using the N-methoxycarbonylmethyl ester (MCM) derivative of L-[1-C-13]valine and on-line gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). The derivatization procedure can be performed rapidly and GC sep

  18. Determination of low isotopic enrichment of L-[1-C-13]valine by gas chromatography combustion isotope ratio mass spectrometry : a robust method for measuring protein fractional synthetic rates in vivo

    NARCIS (Netherlands)

    Reijngoud, DJ; Hellstern, G; Elzinga, H; de Sain-van der Velden, MG; Okken, A; Stellaard, F

    A method was developed for measuring protein fractional synthetic rates using the N-methoxycarbonylmethyl ester (MCM) derivative of L-[1-C-13]valine and on-line gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). The derivatization procedure can be performed rapidly and GC

  19. Carbon isotope ratio analysis of organic moieties from fossil mummified wood: establishing optimum conditions for off-line pyrolysis extraction using gas chromatography/mass spectrometry

    NARCIS (Netherlands)

    Poole, I.J.; Bergen, P.F. van

    2002-01-01

    Mummified fossil wood was studied using off-line pyrolysis-gas chromatography/mass spectrometry to reveal detailed insights into the pyrolysis conditions that are needed to obtain simultaneously sufficient amounts of both cellulose and lignin markers for stable carbon isotope analyses. The off-line

  20. Carbon isotope ratio analysis of organic moieties from fossil mummified wood: establishing optimum conditions for off-line pyrolysis extraction using gas chromatography/mass spectrometry

    NARCIS (Netherlands)

    Poole, I.J.; Bergen, P.F. van

    2002-01-01

    Mummified fossil wood was studied using off-line pyrolysis-gas chromatography/mass spectrometry to reveal detailed insights into the pyrolysis conditions that are needed to obtain simultaneously sufficient amounts of both cellulose and lignin markers for stable carbon isotope analyses. The off-line

  1. Isolation of Pu-isotopes from environmental samples using ion chromatography for accelerator mass spectrometry and alpha spectrometry.

    Science.gov (United States)

    Chamizo, E; Jiménez-Ramos, M C; Wacker, L; Vioque, I; Calleja, A; García-León, M; García-Tenorio, R

    2008-01-14

    A radiochemical method for the isolation of plutonium-isotopes from environmental samples, based on the use of specific extraction chromatography resins for actinides (TEVA), Eichrom Industries, Inc.), has been set up in our laboratory and optimised for their posterior determination by alpha spectrometry (AS) or accelerator mass spectrometry (AMS). The proposed radiochemical method has replaced in our lab a well-established one based on the use of a relatively un-specific anion-exchange resin (AG) 1X8, Bio-rad Laboratories, Inc.), because it is clearly less time consuming, reduces the amounts and molarities of acid wastes produced, and reproducibly gives high radiochemical yields. In order to check the reliability of the proposed radiochemical method for the determination of plutonium-isotopes in different environmental matrixes, twin aliquots of a set of samples were prepared with TEVA and with AG 1X8 resins and measured by AS. Some samples prepared with TEVA resins were measured as well by AMS. As it is shown in the text, there is a comfortable agreement between AS and AMS, which adequately validates the method.

  2. Isolation of Pu-isotopes from environmental samples using ion chromatography for accelerator mass spectrometry and alpha spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Chamizo, E. [Centro Nacional de Aceleradores (CNA), Avda. Thomas A. Edison, 41092 Sevilla (Spain)], E-mail: elechacal@alum.us.es; Jimenez-Ramos, M.C. [Applied Nuclear Physics Group, University of Sevilla, P.O. Box 1065, 41080 Sevilla (Spain); Wacker, L. [Institute of Particle Physics, ETH Hoenggerberg, CH-8093 Zuerich (Switzerland); Vioque, I.; Calleja, A. [Applied Nuclear Physics Group, University of Sevilla, P.O. Box 1065, 41080 Sevilla (Spain); Garcia-Leon, M. [Centro Nacional de Aceleradores (CNA), Avda. Thomas A. Edison, 41092 Sevilla (Spain); Applied Nuclear Physics Group, University of Sevilla, P.O. Box 1065, 41080 Sevilla (Spain); Garcia-Tenorio, R. [Applied Nuclear Physics Group, University of Sevilla, P.O. Box 1065, 41080 Sevilla (Spain)

    2008-01-14

    A radiochemical method for the isolation of plutonium-isotopes from environmental samples, based on the use of specific extraction chromatography resins for actinides (TEVA, Eichrom Industries, Inc.), has been set up in our laboratory and optimised for their posterior determination by alpha spectrometry (AS) or accelerator mass spectrometry (AMS). The proposed radiochemical method has replaced in our lab a well-established one based on the use of a relatively un-specific anion-exchange resin (AG 1X8, Bio-rad Laboratories, Inc.), because it is clearly less time consuming, reduces the amounts and molarities of acid wastes produced, and reproducibly gives high radiochemical yields. In order to check the reliability of the proposed radiochemical method for the determination of plutonium-isotopes in different environmental matrixes, twin aliquots of a set of samples were prepared with TEVA and with AG 1X8 resins and measured by AS. Some samples prepared with TEVA resins were measured as well by AMS. As it is shown in the text, there is a comfortable agreement between AS and AMS, which adequately validates the method.

  3. Simultaneous assessment of cholesterol absorption and synthesis in humans using on-line gas chromatography/ combustion and gas chromatography/pyrolysis/isotope-ratio mass spectrometry.

    Science.gov (United States)

    Gremaud, G; Piguet, C; Baumgartner, M; Pouteau, E; Decarli, B; Berger, A; Fay, L B

    2001-01-01

    A number of dietary components and drugs are known to inhibit the absorption of dietary and biliary cholesterol, but at the same time can compensate by increasing cholesterol synthesis. It is, therefore, necessary to have a convenient and accurate method to assess both parameters simultaneously. Hence, we validated such a method in humans using on-line gas chromatography(GC)/combustion and GC/pyrolysis/isotope-ratio mass spectrometry (IRMS). Cholesterol absorption was measured using the ratio of [(13)C]cholesterol (injected intravenously) to [(18)O]cholesterol (administered orally). Simultaneously, cholesterol synthesis was measured using the deuterium incorporation method. Our methodology was applied to 12 mildly hypercholesterolemic men that were given a diet providing 2685 +/- 178 Kcal/day (mean +/- SD) and 255 +/- 8 mg cholesterol per day. Cholesterol fractional synthesis rates ranged from 5.0 to 10.5% pool/day and averaged 7.36% +/- 1.78% pool/day (668 +/- 133 mg/day). Cholesterol absorption ranged from 36.5-79.9% with an average value of 50.8 +/- 15.4%. These values are in agreement with already known data obtained with mildly hypercholesterolemic Caucasian males placed on a diet similar to the one used for this study. However, our combined IRMS method has the advantage over existing methods that it enables simultaneous measurement of cholesterol absorption and synthesis in humans, and is therefore an important research tool for studying the impact of dietary treatments on cholesterol parameters.

  4. Analysis of liposoluble carboxylic acids metabolome in human serum by stable isotope labeling coupled with liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Zhu, Quan-Fei; Zhang, Zheng; Liu, Ping; Zheng, Shu-Jian; Peng, Ke; Deng, Qian-Yun; Zheng, Fang; Yuan, Bi-Feng; Feng, Yu-Qi

    2016-08-19

    Fatty acids (FAs) are groups of liposoluble carboxylic acids (LCAs) and play important roles in various physiological processes. Abnormal contents or changes of FAs are associated with a series of diseases. Here we developed a strategy with stable isotope labeling combined with liquid chromatography-tandem mass spectrometry (IL-LC-MS) analysis for comprehensive profiling and relative quantitation of LCAs in human serum. In this strategy, a pair of isotope labeling reagents (2-dimethylaminoethylamine (DMED)) and d4-2-dimethylaminoethylamine (d4-DMED) were employed to selectively label carboxyl groups of LCAs. The DMED and d4-DMED labeled products can lose four characteristic neutral fragments of 45 and 49Da or 63 and 67Da in collision-induced dissociation. Therefore, quadruple neutral loss scan (QNLS) mode was established and used for non-targeted profiling of LCAs. The peak pairs of DMED and d4-DMED labeling with the same retention time, intensity and characteristic mass differences were extracted from the two NLS spectra respectively, and assigned as potential LCA candidates. Using this strategy, 241 LCA candidates were discovered in the human serum; 156 carboxylic acid compounds could be determined by searching HMDB and METLIN databases (FAs are over 90%) and 21 of these LCAs were successfully identified by standards. Subsequently, a modified pseudo-targeted method with multiple reaction monitoring (MRM) detection mode was developed and used for relative quantification of LCAs in human serum from type 2 diabetes mellitus (T2DM) patients and healthy controls. As a result, 81 LCAs were found to have significant difference between T2DM patients and healthy controls. Taken together, the isotope labeling combined with tandem mass spectrometry analysis demonstrated to be a powerful strategy for identification and quantification of LCA compounds in serum samples.

  5. Activity coefficients at infinite dilution of organic solutes in the ionic liquid trihexyl(tetradecyl)phosphonium tetrafluoroborate using gas-liquid chromatography at T = (313.15, 333.15, 353.15, and 373.15) K

    Energy Technology Data Exchange (ETDEWEB)

    Tumba, Kaniki; Reddy, Prashant; Naidoo, Paramespri [Thermodynamics Research Unit, School of Chemical Engineering, University of KwaZulu-Natal, Howard College Campus, King George V Avenue, Durban 4041 (South Africa); Ramjugernath, Deresh, E-mail: ramjuger@ukzn.ac.z [Thermodynamics Research Unit, School of Chemical Engineering, University of KwaZulu-Natal, Howard College Campus, King George V Avenue, Durban 4041 (South Africa)

    2011-05-15

    Research highlights: Activity coefficients at infinite dilution in the ionic liquid [3C{sub 6}C{sub 14}P][BF{sub 4}]. Twenty-seven solutes investigated at T = (313.15, 333.15, 353.15, and 373.15) K. [3C{sub 6}C{sub 14}P][BF{sub 4}] shows promise for the separation of aromatic and alcohol mixtures. - Abstract: Activity coefficients at infinite dilution have been measured by gas-liquid chromatography for 27 organic solutes (n-alkanes, 1-alkenes, 1-alkynes, cycloalkanes, aromatics, alcohols, and ketones) in the ionic liquid trihexyl(tetradecyl)phosphonium tetrafluoroborate [3C{sub 6}C{sub 14}P][BF{sub 4}]. The measurements were carried out at four different temperatures viz.T = (313.15, 333.15, 353.15, and 373.15) K. From the experimental data, partial molar excess enthalpy values at infinite dilution were calculated for the experimental temperature range. The selectivity values for the separation of n-hexane/benzene, cyclohexane/benzene, and methanol/benzene mixtures were determined from the experimental infinite dilution activity coefficient values. These values were compared to those available in the literature for other ionic liquids and commercial solvents, so as to assess the feasibility of employing [3C{sub 6}C{sub 14}P][BF{sub 4}] in solvent-enhanced industrial separations.

  6. Determination of Cd, Hg, Pb and Tl in coal and coal fly ash slurries using electrothermal vaporization inductively coupled plasma mass spectrometry and isotopic dilution

    Energy Technology Data Exchange (ETDEWEB)

    Maia, S.M.; Pozebon, D.; Curtius, A.J. [Univ. Federal de Santa Catarina, Florianopolis, SC (Brazil)

    2003-07-01

    A method has been investigated for the determination of Cd, Hg, Pb and Tl in coal and in coal fly ash, using slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry and isotope dilution. The slurry, 25 mg ml{sup -1}, was prepared by mixing the powdered sample (less than or equal to 36 - 45 mm) with acid solutions (nitric acid for coal and nitric and hydrofluoric acids for coal fly ash) and submitting the mixture to an ultrasonic agitation, letting it stand afterwards in a water bath at 60{sup o}C for 2 h. An ultrasonic probe was used to homogenize the slurry in the autosampler cup just before its introduction into the graphite tube. The best conditions were determined regarding analyte sensitivity, furnace temperature program, amount of modifier, acid concentration, gas flow rate and particle size. For Hg, the pyrolysis stage was omitted and a low vaporization temperature was used (450 - 1000{sup o}C); the residual matrix was eliminated in the first step of the following cycle. The modifiers used were: Pd for Cd and Tl; Au, Ir or Pd for Hg; Ir or Pd for Pb. The accuracy of the method was checked by analyzing six certified coal reference materials (SARM 20, SARM 19, BCR No. 40, BCR No. 180, BCR No. 181 and NIST 1630a) and one certified coal fly ash (NIST 1633b). With one exception (Hg in BCR No. 180), the found concentrations were typically within 95% confidence interval of the certified values, or close enough to the recommended values, as long as the samples were ground to a small enough particle size. The limits of detection were typically around 0.08 {mu}g g{sup -1}, 0.03 {mu}g g{sup -1}, 1 {mu}g g{sup -1} and 0.02 {mu}g g{sup -1} for Cd, Hg, Pb and Tl, respectively. The precision was also adequate with relative standard deviations of usually < 5%.

  7. Optimisation of sample preparation protocols for measurement of PGE and Re-Os in organic-rich shales by isotope dilution ICP-MS

    Science.gov (United States)

    Rammensee, Philipp; Aulbach, Sonja; Gudelius, Dominik; Brey, Gerhard

    2013-04-01

    Platinum-group elements (PGE) and Re-Os isotopes, which are variably redox-sensitive and fluid-soluble, have potential as proxies for the oxygenation of the atmosphere and oceans (e.g. [1]). However, analysis of these elements in organic rich shales (ORS) is challenging due to abundances of chromatography is necessary to minimise the effects of interfering elements, but presents its own challenges. We are in the process of conducting variations of acid digestion and column chromatographic protocols on reference sample SDO-1 (Devonian Ohio Shale, USGS). We aim to identify the optimum protocol to investigate PGE-Re-Os systematics of ORS that were sampled as part of the Barberton Drilling Project BARB5 drill core, in order to constrain the changes in detrital and hydrogenous contributions to the sediment with time, to assess the extent of euxinity in the sedimentary basin and to look for evidence of transient "whiffs of oxygen" [1]. The following digestion methods were tested: (1) 4h acid digestion in High Pressure Asher (HPA) apparatus with reverse aqua regia at 300°C and 130 bar (only this digestion allows extraction of volatilised Os in CHCl3 followed by HBr); (2) 3h reverse aqua regia digestion in centrifuge vials on hotplate at 80°C; (3) 48h reverse aqua regia digestion in closed Teflon beakers on hotplate at 140°C followed by a HF/HNO3 digestion step; (4) 48h HF/HNO3 digestion of ashed sample powder in closed Teflon beaker at 140°C on hotplate followed by an aqua regia digestion step. Column chromatographic approaches to decrease the concentrations of interfering elements (Y, Zr, Mo, Cd, Hf, Hg) include the use of cation- and anion resins, and variations of the molarity and composition of the eluent. Preliminary results show that digestion method (1) leaves behind small amounts of presumably PGE-free silica gel; (2) yields consistently higher Re concentrations with an expectedly large amount of solid residue; (3) produces an insoluble sludge; (4) allows

  8. 同位素稀释-ICPMS法测定地质标准物质中铂族元素%Determination of Platinum-group Elements in the Geological Standard Reference Materials by Isotope Dilution-ICPMS

    Institute of Scientific and Technical Information of China (English)

    胡明月; 何红蓼

    2005-01-01

    Platinum group elements (PGEs) includes platinum, palladium, iridium, osmium, rhodium and ruthenium. It has very high economic and scientific value in the field of geoscience and environmental science. But the analysis data referred by the different lab are very disperse because of the difficulty of the determination of PGEs. It makes very difficult to fix the value of the PGEs in the standard reference materials. In the article, the values of the PGEs in the standard reference materials of ocean sediment are determined by isotope dilution technique and dependable values of these elements are provided.

  9. Stable isotope labeling assisted liquid chromatography-electrospray tandem mass spectrometry for quantitative analysis of endogenous gibberellins.

    Science.gov (United States)

    Hao, Yan-Hong; Zhang, Zheng; Wang, Lu; Liu, Chao; Lei, Ai-Wen; Yuan, Bi-Feng; Feng, Yu-Qi

    2015-11-01

    In the current study, we developed a stable isotope labeling strategy for the absolute quantification of gibberellins (GAs) by high performance liquid chromatography-electrospray tandem mass spectrometry (HPLC-ESI-MS/MS). N,N-dimethyl ethylenediamine (DMED) and its deuterated counterpart d(4)-DMED were used to derivatize GAs extracted from plant tissue samples and GA standards respectively. The both derivatives of GAs were mixed and then subjected to HPLC-ESI-MS/MS analysis. The absolute quantification of GAs in plant tissues could be achieved by calculating the peak area ratios of DMED labeled GAs/d(4)-DMED labeled GAs. In the proposed strategy, the derivatization reaction of the labeling reagents with GAs could be completed rapidly (within 5 min) with high efficiency (>99%) under mild conditions. The resulting derivatives could produce specific fragments in collision induced dissociation (CID), leading to high selectivity in multiple-reaction monitoring (MRM) mode, thus enhanced the reliability of the LC-MS/MS method. Furthermore, the limits of quantitation (LOQs) of GAs were considerably decreased (2-32 folds) due to incorporating easily ionized moieties into GAs, and the quantification of GAs in plant tissue could be achieved without isotopically labeled GA standards. Good linearity was obtained with correlation coefficients R(2) values of >0.99. The limits of detection (LODs) and quantitation (LOQs) ranged from 0.02 to 0.74 pg and 0.07 to 2.45 pg, respectively. Eleven GAs could be successfully determined in spiked sample with 72-128% recoveries and the relative standard deviations (RSDs) were between 1.0% and 13.9%. Finally, the developed method was successfully applied for the detection of GAs in 50mg (fresh weight) Oryza sativa leaves.

  10. LC-HR-MS/MS standard urine screening approach: Pros and cons of automated on-line extraction by turbulent flow chromatography versus dilute-and-shoot and comparison with established urine precipitation.

    Science.gov (United States)

    Helfer, Andreas G; Michely, Julian A; Weber, Armin A; Meyer, Markus R; Maurer, Hans H

    2017-02-01

    Comprehensive urine screening for drugs and metabolites by LC-HR-MS/MS using Orbitrap technology has been described with precipitation as simple workup. In order to fasten, automate, and/or simplify the workup, on-line extraction by turbulent flow chromatography and a dilute-and-shoot approach were developed and compared. After chromatographic separation within 10min, the Q-Exactive mass spectrometer was run in full scan mode with positive/negative switching and subsequent data dependent acquisition mode. The workup approaches were validated concerning selectivity, recovery, matrix effects, process efficiency, and limits of identification and detection for typical drug representatives and metabolites. The total workup time for on-line extraction was 6min, for the dilution approach 3min. For comparison, the established urine precipitation and evaporation lasted 10min. The validation results were acceptable. The limits for on-line extraction were comparable with those described for precipitation, but lower than for dilution. Thanks to the high sensitivity of the LC-HR-MS/MS system, all three workup approaches were sufficient for comprehensive urine screening and allowed fast, reliable, and reproducible detection of cardiovascular drugs, drugs of abuse, and other CNS acting drugs after common doses.

  11. Stable isotope labeling – Liquid chromatography/mass spectrometry for quantitative analysis of androgenic and progestagenic steroids

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Ning; Liu, Ping; Ding, Jun; Zheng, Shu-Jian; Yuan, Bi-Feng; Feng, Yu-Qi, E-mail: yqfeng@whu.edu.cn

    2016-01-28

    Steroid hormones play important roles in mammal at very low concentrations and are associated with numerous endocrinology and oncology diseases. Therefore, quantitative analysis of steroid hormones can provide crucial information for uncovering underlying mechanisms of steroid hormones related diseases. In the current study, we developed a sensitive method for the detection of steroid hormones (progesterone, dehydroepiandrosterone, testosterone, pregnenolone, 17-hydroxyprogesterone, androstenedione and 17α-hydroxypregnenolone) in body fluids by stable isotope labeling coupled with liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis. In this respect, a pair of isotopes labeling reagents, Girard reagent P (GP) and d{sub 5}-Girard reagent P (d{sub 5}-GP), were synthesized and utilized to label steroid hormones in follicular fluid samples and steroid hormone standards, respectively. The heavy labeled standards were used as internal standards for quantification to minimize quantitation deviation in MS analysis due to the matrix and ion suppression effects. The ionization efficiencies of steroid hormones were greatly improved by 4–504 folds through the introduction of a permanent charged moiety of quaternary ammonium from GP. Using the developed method, we successfully quantified steroid hormones in human follicular fluid. We found that the contents of testosterone and androstenedione exhibited significant increase while the content of pregnenolone had significant decrease in follicular fluid of polycystic ovarian syndrome (PCOS) patients compared with healthy controls, indicating that these steroid hormones with significant change may contribute to the pathogenesis of PCOS. Taken together, the developed stable isotope labeling coupled LC-ESI-MS/MS analysis demonstrated to be a promising method for the sensitive and accurate determination of steroid hormones, which may facilitate the in-depth investigation of steroid hormones

  12. Differential isotope dansylation labeling combined with liquid chromatography mass spectrometry for quantification of intact and N-terminal truncated proteins.

    Science.gov (United States)

    Tang, Yanan; Li, Liang

    2013-08-20

    The N-terminal amino acids of proteins are important structure units for maintaining the biological function, localization, and interaction networks of proteins. Under different biological conditions, one or several N-terminal amino acids could be cleaved from an intact protein due to processes, such as proteolysis, resulting in the change of protein properties. Thus, the ability to quantify the N-terminal truncated forms of proteins is of great importance, particularly in the area of development and production of protein-based drugs where the relative quantity of the intact protein and its truncated form needs to be monitored. In this work, we describe a rapid method for absolute quantification of protein mixtures containing intact and N-terminal truncated proteins. This method is based on dansylation labeling of the N-terminal amino acids of proteins, followed by microwave-assisted acid hydrolysis of the proteins into amino acids. It is shown that dansyl labeled amino acids are stable in acidic conditions and can be quantified by liquid chromatography mass spectrometry (LC-MS) with the use of isotope analog standards.

  13. Identification of fentanyl metabolites in rat urine by gas chromatography-mass spectrometry with stable-isotope tracers

    Energy Technology Data Exchange (ETDEWEB)

    Goromaru, T.; Matsuura, H.; Furuta, T.; Baba, S.; Yoshimura, N.; Miyawaki, T.; Sameshima, T.

    The metabolites of fentanyl (l), which has been widely used as a neuroleptic analgesic agent, were identified in urine of rats by gas chromatography-mass spectrometry combined with a stable-isotope tracer technique. After the oral administration of an equimolar mixture of l and deuterium-labeled l (l/l-d5), the urinary metabolites were extracted with chloroform at pH 9.0. Extracts were derivatized and analyzed by GC/MS. Metabolites were identified by the presence of doublet ion peaks separated by 5 amu, and chemical structures were established from analyses of fragmentation pathways. The metabolites were identified as 4-N-(N-propionylanilino)-piperidine, 4-N-(N-hydroxypropionylanilino)piperidine, 4-N-(N-propionylanilino) hydroxypiperidine, 1-(2-phenethyl)-4-N-(N-hydroxypropionylanilino)piperidine and 1-(2-phenethyl)-4-N-(N-propionylanilino)hydroxypiperidine. These metabolites, together with unchanged l, were also detected in urine of rats receiving l/l-d5 intravenously, by selected-ion monitoring of the specific cluster ions.

  14. Stable Chlorine Isotopes and Elemental Chlorine by Thermal Ionization Mass Spectrometry and Ion Chromatography; Martian Meteorites, Carbonaceous Chondrites and Standard Rocks

    Science.gov (United States)

    Nakamura, N.; Nyquist, L. E.; Reese, Y.; Shih, C.-Y.; Fujitani, T.; Okano, O.

    2011-01-01

    Recently significantly large mass fractionation of stable chlorine isotopes has been reported for terrestrial and lunar samples [1,2]. In addition, in view of possible early solar system processes [3] and also potential perchlorate-related fluid/microbial activities on the Martian surface [4,5], a large chlorine isotopic fractionation might be expected for some types of planetary materials. Due to analytical difficulties of isotopic and elemental analyses, however, current chlorine analyses for planetary materials are controversial among different laboratories, particularly between IRMS (gas source mass spectrometry) and TIMS (Thermal Ionization Mass Spectrometry) groups [i.e. 1,6,7] for isotopic analyses, as well as between those doing pyrohydrolysis and other groups [i.e. 6,8]. Additional careful investigations of Cl isotope and elemental abundances are required to confirm real chlorine isotope and elemental variations for planetary materials. We have developed a TIMS technique combined with HF-leaching/ion chromatography at NASA JSC that is applicable to analysis of small amounts of meteoritic and planetary materials. We present here results for several standard rocks and meteorites, including Martian meteorites.

  15. delta 13C analyses of vegetable oil fatty acid components, determined by gas chromatography--combustion--isotope ratio mass spectrometry, after saponification or regiospecific hydrolysis.

    Science.gov (United States)

    Woodbury, S E; Evershed, R P; Rossell, J B

    1998-05-01

    The delta 13C values of the major fatty acids of several different commercially important vegetable oils were measured by gas chromatography--combustion--isotope ratio mass spectrometry. The delta 13C values obtained were found to fall into two distinct groups, representing the C3 and C4 plants classes from which the oils were derived. The delta 13C values of the oils were measured by continuous flow elemental isotope ratio mass spectrometry and were found to be similar to their fatty acids, with slight differences between individual fatty acids. Investigations were then made into the influence on the delta 13C values of fatty acids of the position occupied on the glycerol backbone. Pancreatic lipase was employed to selectively hydrolyse fatty acids from the 1- and 3-positions with the progress of the reaction being followed by high-temperature gas chromatography in order to determine the optimum incubation time. The 2-monoacylglycerols were then isolated by thin-layer chromatography and fatty acid methyl esters prepared. The delta 13C values obtained indicate that fatty acids from any position on the glycerol backbone are isotopically identical. Thus, whilst quantification of fatty acid composition at the 2-position and measurement of delta 13C values of oils and their major fatty acids are useful criteria in edible oil purity assessment, measurement of delta 13C values of fatty acids from the 2-position does not assist with oil purity assignments.

  16. Rapid Determination of Plutonium Isotopes in Environmental Samples Using Sequential Injection Extraction Chromatography and Detection by Inductively Coupled Plasma Mass Spectrometry

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2009-01-01

    by detection of isolated analytes with inductively coupled plasma mass spectrometry (ICP-MS). The method has been devised for the determination of Pu isotopes at environmentally relevant concentrations, whereby it has been successfully applied to the analyses of large volumes/amounts of samples, for example......This article presents an automated method for the rapid determination of 239Pu and 240Pu in various environmental samples. The analytical method involves the in-line separation of Pu isotopes using extraction chromatography (TEVA) implemented in a sequential injection (SI) network followed....... The analytical results of Pu isotopes in the reference materials showed good agreement with the certified or reference values at the 0.05 significance level. Chemical yields of Pu ranged from 80 to 105%, and the decontamination factors for uranium, thorium, mercury and lead were all above 104. The duration...

  17. (37)Cl/(35)Cl isotope ratio analysis in perchlorate by ion chromatography/multi collector -ICPMS: Analytical performance and implication for biodegradation studies.

    Science.gov (United States)

    Zakon, Yevgeni; Ronen, Zeev; Halicz, Ludwik; Gelman, Faina

    2017-10-01

    In the present study we propose a new analytical method for (37)Cl/(35)Cl analysis in perchlorate by Ion Chromatography(IC) coupled to Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICPMS). The accuracy of the analytical method was validated by analysis of international perchlorate standard materials USGS-37 and USGS -38; analytical precision better than ±0.4‰ was achieved. (37)Cl/(35)Cl isotope ratio analysis in perchlorate during laboratory biodegradation experiment with microbial cultures enriched from the contaminated soil in Israel resulted in isotope enrichment factor ε(37)Cl = -13.3 ± 1‰, which falls in the range reported previously for perchlorate biodegradation by pure microbial cultures. The proposed analytical method may significantly simplify the procedure for isotope analysis of perchlorate which is currently applied in environmental studies. Copyright © 2017. Published by Elsevier Ltd.

  18. Characterization of bile acid metabolism in man using bile acids labeled with stable isotopes. [/sup 13/C

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, A.F. Klein, P.D.

    1977-01-01

    Bile acids labeled with stable isotopes in the steroid moiety can be used to characterize bile acid metabolism in man. Isotope dilution studies give information on pool size and input. Biotransformations are easily characterized. Stable isotopically labeled bile acids offer the advantage of freedom from radiation hazard, and also offer the possibility of monitoring all pools simultaneously, since all bile acids are separated by gas chromatography before isotope measurements are made. Further, since the proportion of the pool labeled with stable isotopes is greater than that achieved when radioactive isotopes are used, stable isotopes may permit isotope dilution studies to be done on serum samples in which the absolute concentration of bile acids is very low. A major disadvantage is the complex technology required for stable isotope measurement which often makes remote processing necessary. Bile acid labeled with /sup 13/C in the amino acid moiety, e.g. cholylglycine-1-/sup 13/C can be used for detection of increased bile acid deconjugation by intestinal bacteria, since the glycine-/sup 13/C, when liberated, is rapidly converted to /sup 13/CO/sub 2/, which is expired in breath. Bile acids labeled with stable isotopes may also be used for quantitation by inverse isotope dilution, but the technique is still in the development stage and seems unlikely to compete successfully with radioimmunoassay.

  19. Determination of selected endogenous anabolic androgenic steroids and ratios in urine by ultra high performance liquid chromatography tandem mass spectrometry and isotope pattern deconvolution.

    Science.gov (United States)

    Pitarch-Motellón, J; Sancho, J V; Ibáñez, M; Pozo, O; Roig-Navarro, A F

    2017-09-15

    An isotope dilution mass spectrometry (IDMS) method for the determination of selected endogenous anabolic androgenic steroids (EAAS) in urine by UHPLC-MS/MS has been developed using the isotope pattern deconvolution (IPD) mathematical tool. The method has been successfully validated for testosterone, epitestosterone, androsterone and etiocholanolone, employing their respective deuterated analogs using two certified reference materials (CRM). Accuracy was evaluated as recovery of the certified values and ranged from 75% to 108%. Precision was assessed in intraday (n=5) and interday (n=4) experiments, with RSDs below 5% and 10% respectively. The method was also found suitable for real urine samples, with limits of detection (LOD) and quantification (LOQ) below the normal urinary levels. The developed method meets the requirements established by the World Anti-Doping Agency for the selected steroids for Athlete Biological Passport (ABP) measurements, except in the case of androsterone, which is currently under study. Copyright © 2017. Published by Elsevier B.V.

  20. Sensitive determination of thiols in wine samples by a stable isotope-coded derivatization reagent d0/d4-acridone-10-ethyl-N-maleimide coupled with high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry analysis.

    Science.gov (United States)

    Lv, Zhengxian; You, Jinmao; Lu, Shuaimin; Sun, Weidi; Ji, Zhongyin; Sun, Zhiwei; Song, Cuihua; Chen, Guang; Li, Guoliang; Hu, Na; Zhou, Wu; Suo, Yourui

    2017-03-31

    As the key aroma compounds, varietal thiols are the crucial odorants responsible for the flavor of wines. Quantitative analysis of thiols can provide crucial information for the aroma profiles of different wine styles. In this study, a rapid and sensitive method for the simultaneous determination of six thiols in wine using d0/d4-acridone-10-ethyl-N-maleimide (d0/d4-AENM) as stable isotope-coded derivatization reagent (SICD) by high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) has been developed. Quantification of thiols was performed by using d4-AENM labeled thiols as the internal standards (IS), followed by stable isotope dilution HPLC-ESI-MS/MS analysis. The AENM derivatization combined with multiple reactions monitoring (MRM) not only allowed trace analysis of thiols due to the extremely high sensitivity, but also efficiently corrected the matrix effects during HPLC-MS/MS and the fluctuation in MS/MS signal intensity due to instrument. The obtained internal standard calibration curves for six thiols were linear over the range of 25-10,000pmol/L (R(2)≥0.9961). Detection limits (LODs) for most of analytes were below 6.3pmol/L. The proposed method was successfully applied for the simultaneous determination of six kinds of thiols in wine samples with precisions ≤3.5% and recoveries ≥78.1%. In conclusion, the developed method is expected to be a promising tool for detection of trace thiols in wine and also in other complex matrix. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Distribution of the hallucinogens N,N-dimethyltryptamine and 5-methoxy-N,N-dimethyltryptamine in rat brain following intraperitoneal injection: application of a new solid-phase extraction LC-APcI-MS-MS-isotope dilution method.

    Science.gov (United States)

    Barker, S A; Littlefield-Chabaud, M A; David, C

    2001-02-10

    A method for the solid-phase extraction (SPE) and liquid chromatographic-atmospheric pressure chemical ionization-mass spectrometric-mass spectrometric-isotope dilution (LC-APcI-MS-MS-ID) analysis of the indole hallucinogens N,N-dimethyltryptamine (DMT) and 5-methoxy DMT (or O-methyl bufotenin, OMB) from rat brain tissue is reported. Rats were administered DMT or OMB by the intraperitoneal route at a dose of 5 mg/kg and sacrificed 15 min post treatment. Brains were dissected into discrete areas and analyzed by the methods described as a demonstration of the procedure's applicability. The synthesis and use of two new deuterated internal standards for these purposes are also reported.

  2. The complete targeted profile of the organic acid intermediates of the citric acid cycle using a single stable isotope dilution analysis, sodium borodeuteride reduction and selected ion monitoring GC/MS.

    Science.gov (United States)

    Mamer, Orval; Gravel, Simon-Pierre; Choinière, Luc; Chénard, Valérie; St-Pierre, Julie; Avizonis, Daina

    2013-01-01

    The quantitative profiling of the organic acid intermediates of the citric acid cycle (CAC) presents a challenge due to the lack of commercially available internal standards for all of the organic acid intermediates. We developed an analytical method that enables the quantitation of all the organic acids in the CAC in a single stable isotope dilution GC/MS analysis with deuterium-labeled analogs used as internal standards. The unstable α-keto acids are rapidly reduced with sodium borodeuteride to the corresponding stable α-deutero-α-hydroxy acids and these, along with their unlabeled analogs and other CAC organic acid intermediates, are converted to their tert-butyldimethylsilyl derivatives. Selected ion monitoring is employed with electron ionization. We validated this method by treating an untransformed mouse mammary epithelial cell line with well-known mitochondrial toxins affecting the electron transport chain and ATP synthase, which resulted in profound perturbations of the concentration of CAC intermediates.

  3. Easy Extraction Method To Evaluate δ13C Vanillin by Liquid Chromatography-Isotopic Ratio Mass Spectrometry in Chocolate Bars and Chocolate Snack Foods.

    Science.gov (United States)

    Bononi, Monica; Quaglia, Giancarlo; Tateo, Fernando

    2015-05-20

    An easy extraction method that permits the use of a liquid chromatography-isotopic ratio mass spectrometry (LC-IRMS) system to evaluate δ(13)C of vanillin in chocolate products and industrial flavorings is presented. The method applies the determination of stable isotopes of carbon to discriminate between natural vanillin from vanilla beans and vanillin from other sources (mixtures from beans, synthesis, or biotechnology). A series of 13 chocolate bars and chocolate snack foods available on the Italian market and 8 vanilla flavorings derived from industrial quality control processes were analyzed. Only 30% of products considered in this work that declared "vanilla" on the label showed data that permitted the declaration "vanilla" according to European Union (EU) Regulation 1334/2008. All samples not citing "vanilla" or "natural flavoring" on the label gave the correct declaration. The extraction method is presented with data useful for statistical evaluation.

  4. Rapid determination of plutonium isotopes in environmental samples using sequential injection extraction chromatography and detection by inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per; Miró, Manuel

    2009-10-01

    This article presents an automated method for the rapid determination of 239Pu and 240Pu in various environmental samples. The analytical method involves the in-line separation of Pu isotopes using extraction chromatography (TEVA) implemented in a sequential injection (SI) network followed by detection of isolated analytes with inductively coupled plasma mass spectrometry (ICP-MS). The method has been devised for the determination of Pu isotopes at environmentally relevant concentrations, whereby it has been successfully applied to the analyses of large volumes/amounts of samples, for example, 100-200 g of soil and sediment, 20 g of seaweed, and 200 L of seawater following analyte preconcentration. The investigation of the separation capability of the assembled SI system revealed that up to 200 g of soil or sediment can be treated using a column containing about 0.70 g of TEVA resin. The analytical results of Pu isotopes in the reference materials showed good agreement with the certified or reference values at the 0.05 significance level. Chemical yields of Pu ranged from 80 to 105%, and the decontamination factors for uranium, thorium, mercury and lead were all above 10(4). The duration of the in-line extraction chromatographic run was determination of Pu isotopes in environmental risk assessment and emergency preparedness scenarios.

  5. Mutually supportive use of stable isotope and gas chromatography techniques to understand ecohydrological interactions in dryland environments

    Science.gov (United States)

    Puttock, A.; Brazier, R. E.; Dungait, J. A. J.; Bol, R.; Dixon, E. R.; Macleod, C. J. A.

    2012-04-01

    Many drylands globally are experiencing extensive vegetation change. In the semi-arid Southwestern United States, this change is characterised by the encroachment of woody vegetation into environments previously dominated by grassland (Van Auken. 2009). The transition from grass to woody vegetation results in a change in ecosystem structure and function (Turnbull et al. 2008). Structural change is typically characterised by an increased heterogeneity of soil and vegetation resources, associated with reduced vegetation coverage and an increased vulnerability to soil erosion and the potential loss of key nutrients to adjacent fluvial systems. This project uses an ecohydrological approach, monitoring natural rainfall-runoff events and resulting water and sediment fluxes over six bounded plots with different vegetation coverage at the Sevilleta National Wildlife Refuge, New Mexico, USA. The experiment takes advantage of a shift in the photosynthetic pathway of dominant vegetation from C3 piñon-juniper (Pinus edulis-Juniperus monosperma) mixed stand through a C4 pure-grass (Bouteloua eriopoda) to C3 shrub (Larrea tridentate). This allows for the utilisation of natural abundance tracing techniques, specifically stable 13C isotope and gas chromatography lipid biomarker analyses. Results collected during the 2010 and 2011 monsoon seasons will be presented, using biogeochemical signatures, to trace and partition fluvial soil organic matter and carbon fluxes during runoff generating rainfall events. Results show that biogeochemical signatures specific to individual plant species can be used to define the provenance of carbon, quantifying whether more Pinus edulis-Juniperus monosperma derived carbon is mobilised from the upland plots, or whether more Larrea tridentata carbon is lost when compared to bouteloa eripoda losses in the lowlands. Results also show that biogeochemical signatures vary with event characteristics, raising the possibility of using these tracing

  6. Insights into the Key Aroma Compounds in Mango (Mangifera indica L. 'Haden') Fruits by Stable Isotope Dilution Quantitation and Aroma Simulation Experiments.

    Science.gov (United States)

    Munafo, John P; Didzbalis, John; Schnell, Raymond J; Steinhaus, Martin

    2016-06-01

    Thirty-four aroma-active compounds, previously identified with high flavor dilution factors by application of an aroma extract dilution analysis, were quantified in tree-ripened fruits of mango (Mangifera indica L. 'Haden'). From the results, the odor activity value (OAV) was calculated for each compound as the ratio of its concentration in the mangoes to its odor threshold in water. OAVs > 1 were obtained for 24 compounds, among which ethyl 2-methylbutanoate (fruity; OAV 2100), (3E,5Z)-undeca-1,3,5-triene (pineapple-like; OAV 1900), ethyl 3-methylbutanoate (fruity; OAV 1600), and ethyl butanoate (fruity; OAV 980) were the most potent, followed by (2E,6Z)-nona-2,6-dienal (cucumber-like), ethyl 2-methylpropanoate (fruity), (E)-β-damascenone (cooked apple-like), ethyl hexanoate (fruity), 4-hydroxy-2,5-dimethyl-3(2H)-furanone (caramel-like), 3-methylbut-2-ene-1-thiol (sulfurous), γ-decalactone (peach-like), β-myrcene (terpeny), (3Z)-hex-3-enal (green), 4-methyl-4-sulfanylpentan-2-one (tropical fruit-like), and ethyl octanoate (fruity). Aroma simulation and omission experiments revealed that these 15 compounds, when combined in a model mixture in their natural concentrations, were able to mimic the aroma of the fruits.

  7. DMSO Assisted Electrospray Ionization for the Detection of Small Peptide Hormones in Urine by Dilute-and-Shoot-Liquid-Chromatography-High Resolution Mass Spectrometry

    Science.gov (United States)

    Judák, Péter; Grainger, Janelle; Goebel, Catrin; Van Eenoo, Peter; Deventer, Koen

    2017-08-01

    The mobile phase additive (DMSO) has been described as a useful tool to enhance electrospray ionization (ESI) of peptides and proteins. So far, this technique has mainly been used in proteomic/peptide research, and its applicability in a routine clinical laboratory setting (i.e., doping control analysis) has not been described yet. This work provides a simple, easy to implement screening method for the detection of doping relevant small peptides (GHRPs, GnRHs, GHS, and vasopressin-analogues) with molecular weight less than 2 kDa applying DMSO in the mobile phase. The gain in sensitivity was sufficient to inject the urine samples after a 2-fold dilution step omitting a time consuming sample preparation. The employed analytical procedure was validated for the qualitative determination of 36 compounds, including 13 metabolites. The detection limits (LODs) ranged between 50 and 1000 pg/mL and were compliant with the 2 ng/mL minimum detection level required by the World Anti-Doping Agency (WADA) for all the target peptides. To demonstrate the feasibility of the work, urine samples obtained from patients who have been treated with desmopressin or leuprolide and urine samples that have been declared as adverse analytical findings were analyzed.

  8. A gas chromatography/pyrolysis/isotope ratio mass spectrometry system for high-precision deltaD measurements of atmospheric methane extracted from ice cores.

    Science.gov (United States)

    Bock, Michael; Schmitt, Jochen; Behrens, Melanie; Möller, Lars; Schneider, Robert; Sapart, Celia; Fischer, Hubertus

    2010-03-15

    Air enclosures in polar ice cores represent the only direct paleoatmospheric archive. Analysis of the entrapped air provides clues to the climate system of the past in decadal to centennial resolution. A wealth of information has been gained from measurements of concentrations of greenhouse gases; however, little is known about their isotopic composition. In particular, stable isotopologues (deltaD and delta(13)C) of methane (CH(4)) record valuable information on its global cycle as the different sources exhibit distinct carbon and hydrogen isotopic composition. However, CH(4) isotope analysis is limited by the large sample size required and the demanding analysis as high precision is required. Here we present a highly automated, high-precision online gas chromatography/pyrolysis/isotope ratio monitoring mass spectrometry (GC/P/irmMS) technique for the analysis of deltaD(CH(4)). It includes gas extraction from ice, preconcentration, gas chromatographic separation and pyrolysis of CH(4) from roughly 500 g of ice with CH(4) concentrations as low as 350 ppbv. Ice samples with approximately 40 mL air and only approximately 1 nmol CH(4) can be measured with a precision of 3.4 per thousand. The precision for 65 mL air samples with recent atmospheric concentration is 1.5 per thousand. The CH(4) concentration can be obtained along with isotope data which is crucial for reporting ice core data on matched time scales and enables us to detect flaws in the measurement procedure. Custom-made script-based processing of MS raw and peak data enhance the system's performance with respect to stability, peak size dependency, hence precision and accuracy and last but not least time requirement.

  9. A workflow for multiclass determination of 256 pesticides in essential oils by liquid chromatography tandem mass spectrometry using evaporation and dilution approaches: Application to lavandin, lemon and cypress essential oils.

    Science.gov (United States)

    Fillatre, Yoann; Rondeau, David; Daguin, Antoine; Communal, Pierre-Yves

    2016-01-01

    This paper describes the determination of 256 multiclass pesticides in cypress and lemon essential oils (EOs) by the way of liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) analysis using the scheduled selected reaction monitoring mode (sSRM) available on a hybrid quadrupole linear ion trap (QLIT) mass spectrometer. The performance of a sample preparation of lemon and cypress EOs based on dilution or evaporation under nitrogen assisted by a controlled heating were assessed. The best limits of quantification (LOQs) were achieved with the evaporation under nitrogen method giving LOQs≤10µgL(-1) for 91% of the pesticides. In addition the very satisfactory results obtained for recovery, repeatability and linearity showed that for EOs of relatively low evaporation temperature, a sample preparation based on evaporation under nitrogen is well adapted and preferable to dilution. By compiling these results with those previously published by some of us on lavandin EO, we proposed a workflow dedicated to multiresidue determination of pesticides in various EOs by LC-ESI/sSRM. Among the steps involved in this workflow, the protocol related to mass spectrometry proposes an alternative confirmation method to the classical SRM ratio criteria based on a sSRM survey scan followed by an information-dependent acquisition using the sensitive enhanced product ion (EPI) scan to generate MS/MS spectra then compared to a reference. The submitted workflow was applied to the case of lemon EOs samples highlighting for the first time the simultaneous detection of 20 multiclass pesticides in one EO. Some pesticides showed very high concentration levels with amounts greatly exceeding the mgL(-1).

  10. Innovative analysis of 3-mercaptohexan-1-ol, 3-mercaptohexylacetate and their corresponding disulfides in wine by stable isotope dilution assay and nano-liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Roland, Aurélie; Delpech, Stéphane; Dagan, Laurent; Ducasse, Marie-Agnès; Cavelier, Florine; Schneider, Rémi

    2016-10-14

    Both 3-mercaptohexan-1-ol (3MH) and 3-mercaptohexyl acetate (3MHA) were largely studied for the last 20 years due to their pleasant olfactory notes conferred to wine. Until now, many analytical methods focused only on the free forms of both 3MH and 3MHA in wine that provided partial information in the wine aroma evolution. Our study proposes new analytical measurements which allow quantification of both free and disulfide forms of 3MH and 3MHA to better understand the redox phenomenon occurring in wines and further, to orientate wine aroma evolution. Free thiols were analyzed by an original method based on maleimide derivatization allowing in-situ disulfide reduction followed by SIDA-LC-MS/MS analyses exhibiting excellent performances. Indeed, the accuracy ranged from 95 to 110% in three different wine matrices and the repeatability and intermediate reproducibility were inferior to 15% (RSD measurements). Our method exhibited very low limits of detection, which are below to 0.5ng/L and inferior to the perception thresholds of both compounds. Then, this method was applied to three different wines exposed to several oxidative conditions. On the one hand, it was demonstrated that copper sulfate treatment firstly destroyed the total amount of free 3MH to the benefit of thioether and disulfides compounds, with proportions that could be slightly modified by glutathione addition. On the other hand, oxygenation of wines resulted in partial free 3MH destruction to the benefit of thioether compounds. We proposed for the first time an innovative analysis that gives a complete picture of wine aroma, which can be really useful to winemakers to manage wine aroma evolution and to take advantage of the disulfide reservoir. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Quantitative analysis of penicillins in porcine tissues, milk and animal feed using derivatisation with piperidine and stable isotope dilution liquid chromatography tandem mass spectrometry

    NARCIS (Netherlands)

    Holthoon, van F.L.; Mulder, P.P.J.; Bennekom, van E.O.; Heskamp, H.H.; Zuidema, T.; Rhijn, van J.A.

    2010-01-01

    Penicillins are used universally in both human and veterinary medicine. The European Union (EU) has established maximum residue levels (MRLs) for most ß-lactam antibiotics in milk and animal tissues and included them in the National Residue Monitoring Programs. In this study, a novel method is descr

  12. An isotope dilution gas chromatography/mass spectrometry method for trace analysis of xylene and its metabolites in tissues following threshold limit value exposures

    Energy Technology Data Exchange (ETDEWEB)

    Pyon, K.H.; Kracko, D.A.; Strunk, M.R. [and others

    1995-12-01

    The existence of a nose-brain barrier that functions to protect the central nervous system (CNS) from inhaled toxicants has been postulated. Just as a blood-brain barrier protects the CNS from systemic toxicants, the nose-brain barrier may have similar characteristic functions. One component of interest is nasal xenobiotic metabolism and its effect on the transport of pollutants into the CNS at environmentally plausible levels of exposure. Previous results have shown that inhaled xylene are dimethyl phenol (DMP) and methyl benzyl alcohol (MBA), and the nonvolatile metabolites are toluic acid (TA) and methyl hippuric acid (MHA). The nonvolatile metabolites of xylene, along with a small quantity of volatiles, representing either parent xylene or volatile metabolites, are transported via the olfactory epithelium to the glomeruli within the olfactory bulbs of the brain. Further work will be done to establish the linearity for each analyte at the actual highest detection limit of the GC/MS.

  13. Stable-isotope dilution liquid chromatography-electrospray injection tandem mass spectrometry method for fast, selective measurement of S-adenosylmethionine and S-adenosylhomocysteine in plasma.

    NARCIS (Netherlands)

    Gellekink, H.; Oppenraaij-Emmerzaal, D. van; Rooij, A. van; Struys, E.A.; Heijer, M. den; Blom, H.J.

    2005-01-01

    BACKGROUND: It has been postulated that changes in S-adenosylhomocysteine (AdoHcy), a potent inhibitor of transmethylation, provide a mechanism by which increased homocysteine causes its detrimental effects. We aimed to develop a rapid and sensitive method to measure AdoHcy and its precursor S-adeno

  14. Reference values for salivary testosterone in adolescent boys and girls determined using Isotope-Dilution Liquid-Chromatography Tandem Mass Spectrometry (ID-LC-MS/MS).

    Science.gov (United States)

    Büttler, Rahel M; Peper, Jiska S; Crone, Eveline A; Lentjes, Eef G W; Blankenstein, Marinus A; Heijboer, Annemieke C

    2016-05-01

    The measurement of testosterone in saliva is an attractive alternative to serum analysis due to the simple and non-invasive sample collection. In children and adolescents salivary testosterone is mainly measured to investigate whether puberty has started or not. This study aimed to establish reference values for salivary testosterone during puberty in boys and girls. We measured salivary testosterone using ID-LC-MS/MS in a cohort of 131 girls and 123 boys of whom each had salivary testosterone measured at two time points during puberty. Salivary testosterone concentrations start to increase with the start of puberty around eight years and continuously increase up to adult concentrations in the following ten years. Reference values were calculated using the Lambda-Mu-Sigma (LMS)-curve fitting method and provided per year from 8 to 26 years of age in boys and girls. These reference ranges may help clinicians and researchers to interpret salivary testosterone results in both individual patients and study subjects.

  15. 气相色谱-燃烧-同位素比值质谱法测定单体氨基酸的碳稳定同位素组成%Analysis of Stable Carbon Isotope Composition of Individual N-Trifluoroacetyl-Isopropyl Amino Acid Esters by Gas Chromatography-Combustion-Isotope Ratio Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    蔡德陵; 刘金钟; 刘海珍

    2004-01-01

    A combined gas chromatography combustion-isotope ratio mass spectrometry method(GC-C IRMS) for stable carbon isotope analysis of amino acids is presented. Unlike hydrocarbons, amino acids require derivatization prior to GC-C-IRMS analysis. Replicate carbon isotope analyses of trifluoroacetyl isopropyl ester derivatives of 17 amino acids by IRMS revealed that the derivatization process is reproducible. Due to a reproducible isotopic fractionation an empirical correction factor for each individual amino acid is derived separately for derivatives and the original δ13C value of the underivatized amino acid is calculated.

  16. Discovering Mercury Protein Modifications in Whole Proteomes Using Natural Isotope Distributions Observed in Liquid Chromatography-Tandem Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Polacco, Benjamin J.; Purvine, Samuel O.; Zink, Erika M.; LaVoie, Stephen P.; Lipton, Mary S.; Summers, Anne O.; Miller, Susan M.

    2011-08-01

    The identification of peptides that result from post-translational modifications is critical for understanding normal pathways of cellular regulation as well as identifying damage from, or exposures to xenobiotics, i.e. the exposome. However, because of their low abundance in proteomes, effective detection of modified peptides by mass spectrometry (MS) typically requires enrichment to eliminate false identifications. We present a new method for confidently identifying peptides with mercury (Hg)-containing adducts that is based on the influence of mercury’s seven stable isotopes on peptide isotope distributions detected by high-resolution MS. Using a pure protein and E. coli cultures exposed to phenyl mercuric acetate, we show the pattern of peak heights in isotope distributions from primary MS single scans efficiently identified Hg adducts in data from chromatographic separation coupled with tandem mass spectrometry with sensitivity and specificity greater than 90%. Isotope distributions are independent of peptide identifications based on peptide fragmentation (e.g. by SEQUEST), so both methods can be combined to eliminate false positives. Summing peptide isotope distributions across multiple scans improved specificity to 99.4% and sensitivity above 95%, affording identification of an unexpected Hg modification. We also illustrate the theoretical applicability of the method for detection of several less common elements including the essential element, selenium, as selenocysteine in peptides.

  17. Urinary nitrite/nitrate ratio measured by isotope-dilution LC-MS/MS as a tool to screen for urinary tract infections.

    Science.gov (United States)

    Chao, Mu-Rong; Shih, Ying-Ming; Hsu, Yu-Wen; Liu, Hung-Hsin; Chang, Yuan-Jhe; Lin, Bo-Huei; Hu, Chiung-Wen

    2016-04-01

    Urinary tract infections (UTIs) are the most common type of nosocomial infection. Traditionally, the presence of white blood cells and microorganisms in the urine provides objective evidence for UTI diagnosis. Here, we describe the use of liquid chromatography-tandem mass spectrometry (LC-MS/MS) to measure the nitrite and nitrate levels in urine and investigate the potential of this method for UTI diagnosis. LC-MS/MS analysis was performed in positive electrospray ionization mode. After adding (15)N-labeled internal standards and derivatizing with 2,3-diaminonaphthalene (DAN), the urinary nitrite content was directly analyzed by LC-MS/MS, whereas the urinary nitrate was first reduced to nitrite before derivatization and LC-MS/MS analysis. The derivatization of nitrite and enzymatic reduction of nitrate were optimized. This method was then applied to 241 healthy subjects and 73 UTI patients. Optimization tests revealed that 1 mL of crude urine required at least 6.25 μmol of DAN to completely derivatize nitrite and 2.5 U of nitrate reductase to completely reduce nitrate to nitrite. Urinary analysis showed that the urinary concentration of nitrite and the nitrite/nitrate ratio were higher in UTI patients than in healthy subjects. Compared with the dipstick-based urinary nitrite test and using LC-MS/MS to determine the nitrite concentration (sensitivity: 23-25%), the nitrite/nitrate ratio was significantly more sensitive (95%) and exhibited a satisfactory specificity (91%) in the screening of UTIs. Taken together, the nitrite/nitrate ratio, which reflects the reducing ability of pathogenic bacteria, could be a better method for the diagnosis of UTIs that is not subject to variations in urine specimen quality.

  18. Validation of a simplified field-adapted procedure for routine determinations of methyl mercury at trace levels in natural water samples using species-specific isotope dilution mass spectrometry.

    Science.gov (United States)

    Lambertsson, Lars; Björn, Erik

    2004-12-01

    A field-adapted procedure based on species-specific isotope dilution (SSID) methodology for trace-level determinations of methyl mercury (CH(3)Hg(+)) in mire, fresh and sea water samples was developed, validated and applied in a field study. In the field study, mire water samples were filtered, standardised volumetrically with isotopically enriched CH(3) (200)Hg(+), and frozen on dry ice. The samples were derivatised in the laboratory without further pre-treatment using sodium tetraethyl borate (NaB(C(2)H(5))(4)) and the ethylated methyl mercury was purge-trapped on Tenax columns. The analyte was thermo-desorbed onto a GC-ICP-MS system for analysis. Investigations preceding field application of the method showed that when using SSID, for all tested matrices, identical results were obtained between samples that were freeze-preserved or analysed unpreserved. For DOC-rich samples (mire water) additional experiments showed no difference in CH(3)Hg(+) concentration between samples that were derivatised without pre-treatment or after liquid extraction. Extractions of samples for matrix-analyte separation prior to derivatisation are therefore not necessary. No formation of CH(3)Hg(+) was observed during sample storage and treatment when spiking samples with (198)Hg(2+). Total uncertainty budgets for the field application of the method showed that for analyte concentrations higher than 1.5 pg g(-1) (as Hg) the relative expanded uncertainty (REU) was approximately 5% and dominated by the uncertainty in the isotope standard concentration. Below 0.5 pg g(-1) (as Hg), the REU was >10% and dominated by variations in the field blank. The uncertainty of the method is sufficiently low to accurately determine CH(3)Hg(+) concentrations at trace levels. The detection limit was determined to be 4 fg g(-1) (as Hg) based on replicate analyses of laboratory blanks. The described procedure is reliable, considerably faster and simplified compared to non-SSID methods and thereby very

  19. Soil available nitrogen measurement by the electro-ultrafiltration and isotopic dilution technique; Medida do nitrogenio disponivel do solo pela tecnica da eletro-ultrafiltracao e diluicao isotopica ({sup 15} N)

    Energy Technology Data Exchange (ETDEWEB)

    Diez, J.A.; Polo, A. [Consejo Superior de Invetsigaciones Cientificas, Madrid (Spain). Centro de Ciencias Medioambientales

    1991-12-31

    The goal of this work was the evaluation of the available nitrogen of a soil by means of the electro-ultrafiltration (EUF) technique in comparison with the nitrogen taken up plants. The experiment was carried out in posts maintained in a greenhouse, using a yellow Latosol from the Central Amazon rain forest. It was fertilized with labelled K N O{sub 3} (10,616 at % {sup 15} N), using a dose of 254,5 mg N/pot Soil samples were submitted to an extraction by EUF for the quantification of the available nitrogen and after Brachiaria humidicola was cultivated for 60 days. The origin of the nitrogen (fertilizer or soil) was measured by the isotopic dilution technique in soil, EUF extracts and plants. The results showed that both technique values were in the same order of magnitude, with similar percentages of mobilized nitrogen in relation to the total nitrogen in the soil. In relation to the nitrogen derived from fertilizer, the EUF technique extracted 3,48 times more nitrogen than the plants. Nevertheless we have to take into account that the dose of fertilizer was excessive for a species with low capacity of nitrogen assimilation. (author) 10 refs., 4 tabs.

  20. Adulteration Identification of Commercial Honey with the C-4 Sugar Content of Negative Values by an Elemental Analyzer and Liquid Chromatography Coupled to Isotope Ratio Mass Spectroscopy.

    Science.gov (United States)

    Dong, Hao; Luo, Donghui; Xian, Yanping; Luo, Haiying; Guo, Xindong; Li, Chao; Zhao, Mouming

    2016-04-27

    According to the AOAC 998.12 method, honey is considered to contain significant C-4 sugars with a C-4 sugar content of >7%, which are naturally identified as the adulteration. However, the authenticity of honey with a C-4 sugar content of sugars (sucrose, glucose, and fructose), δ(2)H and δ(18)O values, sucrose content, and reducing sugar content of honey using an elemental analyzer and liquid chromatography coupled to isotope ratio mass spectroscopy, was first developed to demonstrate the authenticity of honey with a C-4 sugar content of sugar content (%) sugar content (%) sugar content (%) sugars as well. A very strong correlation is also observed between δ(13)C honey values and δ(13)C protein values of both honey groups. For the δ(18)O value, the C-4 sugar content (%) sugar content (%) sugar content of sugar content of <0%.

  1. Simultaneous quantification of haemoglobin adducts of ethylene oxide, propylene oxide, acrylonitrile, acrylamide and glycidamide in human blood by isotope-dilution GC/NCI-MS/MS.

    Science.gov (United States)

    Schettgen, T; Müller, J; Fromme, H; Angerer, J

    2010-10-01

    Haemoglobin adducts are highly valuable biomarkers of cumulative exposure to carcinogenic substances. We have developed and applied an analytical method for the simultaneous quantification of five haemoglobin adducts of important occupational and environmental carcinogens. The N-terminal adducts were determined with gas chromatography as pentafluorophenylthiohydantoine derivatives according to the modified Edman-procedure and subsequent acetonization of the glycidamide adduct N-(R,S)-2-hydroxy-2-carbamoylethylvaline (GAVal). The use of self-synthesized labelled internal standards in combination with tandem mass spectrometry using negative chemical ionisation guarantees both high accuracy and sensitivity of our determination. The limit of detection for N-2-hydroxyethylvaline (HEVal), N-(R,S)-2-hydroxypropylvaline (HPVal), N-2-carbamoylethylvaline (AAVal) and N-(R,S)-2-hydroxy-2-carbamoylethylvaline (GAVal) was 2 pmol/g globin, for N-2-cyanoethylvaline (CEVal) it was determined as 0.5 pmol/g globin, which was sufficient to determine the background levels of these adducts in the non-smoking general population. The between-day-precision for all analytes using a human blood sample as quality control material ranged from 4.7 to 12.3%. We investigated blood samples of a small group (n=104) of non-smoking persons of the general population for the background levels of these haemoglobin adducts. The median values for HEVal, HPVal, CEVal, AAVal and GAVal in a group of 92 non-smoking persons were 18.1, 4.1, <0.5, 29.9 and 35.2 pmol/g globin, respectively. The adduct levels in 12 persons reporting exposure to passive smoke at home were similar for most adducts with median values of 17.2, 4.1, 1.0, 24.9 and 29.7 pmol/g globin for HEVal, HPVal, CEVal, AAVal and GAVal, respectively. Our results point to an elevated uptake of acrylonitrile caused by passive smoking as indicated by higher levels of the corresponding haemoglobin adduct CEVal.

  2. Bisphenol A and other phenols in urine from Danish children and adolescents analyzed by isotope diluted TurboFlow-LC-MS/MS.

    Science.gov (United States)

    Frederiksen, Hanne; Aksglaede, Lise; Sorensen, Kaspar; Nielsen, Ole; Main, Katharina M; Skakkebaek, Niels E; Juul, Anders; Andersson, Anna-Maria

    2013-11-01

    Bisphenol A (BPA), triclosan (TCS), benzophenone-3 (BP-3), dichoro- and phenyl phenols are industrial chemicals present in numerous consumer products such as polycarbonate plastics, preservatives in personal care products, sun screens, pesticides and fungicides, respectively, and they are all suspected endocrine disrupters. In this study the urinary excretion of eight phenols in Danish children recruited from the general population were investigated. One 24h urine and two consecutive first morning samples were collected from each of 129 healthy Danish children and adolescents (6-21 years). The concentrations of urinary phenols were analyzed by a new on-line TurboFlow-liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. Most of the analyzed phenols were detectable in more than 80% of the 24h urine samples and the median concentration of BPA, TCS, BP-3, 2,4-dichorophenol and 2,5-dichorophenol (analyzed as ∑DCP), 2-phenylphenol and 4-phenylphenol were 1.37, 1.45, 1.41, 0.65, 0.36 and 0.53ng/mL, respectively. The ranges of the excreted TCS and BP-3 were wide; from below limit of detection to maximum levels of 955ng/mL and 162ng/mL, respectively, while the other phenols were excreted in a more narrow range with maximum levels below 25ng/mL. Concentrations in first morning urine were in general higher than in 24h urine and comprised 30-47% of the absolute amount excreted during 24h. The youngest children aged 6-10 years had a significantly higher urinary BPA concentration (ng/mL) and also a relatively higher daily BPA excretion (ng/kg bw/24h) than the older children and adolescents. The opposite pattern was observed for TCS, BP-3 and ∑DCP for which urinary levels increased significantly with age. No gender difference or associations to pubertal development were observed. In conclusion, our study showed that Danish children were exposed to multiple phenols simultaneously. Small children were relatively more exposed to BPA than older children, while higher

  3. Carbon isotope ratio monitoring-gas chromatography mass spectrometric measurements in the marine environment: biomarker sources and paleoclimate applications.

    Science.gov (United States)

    Tolosa, I; Lopez, J F; Bentaleb, I; Fontugne, M; Grimalt, J O

    1999-09-30

    Some applications in the use of compound-specific isotopic analyses (CSIA) for biomarker source elucidation in the marine environment and its potential applications to paleoclimatology are evaluated in the present study. The potential use of the carbon isotope ratios of marine biomarkers as recorders of CO2 levels has been considered. A significant correlation between delta 13C cholesterol of suspended particulates and seawater CO2 concentrations from the south Indian Ocean has been found. delta 13C composition in biomarkers of different functionalities from three photosynthetic organisms has been examined. Small variations within and between biosynthetically related compound classes have been observed in cyanobacteria. In algae, e.g. diatoms and dinoflagellates, significant differences between the average delta 13C composition of fatty acids and sterols were observed (7.5/1000 and 2/1000, respectively). These differences can be attributed to diverse isotope effects associated with different biosynthetic reactions. Isotopic variations among homologues of the same lipid class have also been observed. In diatoms, variations were up to 5/1000 within each class of fatty acids and sterols and in the dinoflagellate species, these variations were lower than 3/1000. These differences, and particularly the intra-specific shifts in delta 13C lipid composition, must be considered for the correct interpretation of changes in delta 13C molecular signatures in the marine environment.

  4. Isotopic Ratio Outlier Analysis of the S. cerevisiae Metabolome Using Accurate Mass Gas Chromatography/Time-of-Flight Mass Spectrometry: A New Method for Discovery.

    Science.gov (United States)

    Qiu, Yunping; Moir, Robyn; Willis, Ian; Beecher, Chris; Tsai, Yu-Hsuan; Garrett, Timothy J; Yost, Richard A; Kurland, Irwin J

    2016-03-01

    Isotopic ratio outlier analysis (IROA) is a (13)C metabolomics profiling method that eliminates sample to sample variance, discriminates against noise and artifacts, and improves identification of compounds, previously done with accurate mass liquid chromatography/mass spectrometry (LC/MS). This is the first report using IROA technology in combination with accurate mass gas chromatography/time-of-flight mass spectrometry (GC/TOF-MS), here used to examine the S. cerevisiae metabolome. S. cerevisiae was grown in YNB media, containing randomized 95% (13)C, or 5%(13)C glucose as the single carbon source, in order that the isotopomer pattern of all metabolites would mirror the labeled glucose. When these IROA experiments are combined, the abundance of the heavy isotopologues in the 5%(13)C extracts, or light isotopologues in the 95%(13)C extracts, follows the binomial distribution, showing mirrored peak pairs for the molecular ion. The mass difference between the (12)C monoisotopic and the (13)C monoisotopic equals the number of carbons in the molecules. The IROA-GC/MS protocol developed, using both chemical and electron ionization, extends the information acquired from the isotopic peak patterns for formulas generation. The process that can be formulated as an algorithm, in which the number of carbons, as well as the number of methoximations and silylations are used as search constraints. In electron impact (EI/IROA) spectra, the artifactual peaks are identified and easily removed, which has the potential to generate "clean" EI libraries. The combination of chemical ionization (CI) IROA and EI/IROA affords a metabolite identification procedure that enables the identification of coeluting metabolites, and allowed us to characterize 126 metabolites in the current study.

  5. Investigation of amino acid δ 13C signatures in bone collagen to reconstruct human palaeodiets using liquid chromatography-isotope ratio mass spectrometry

    Science.gov (United States)

    Choy, Kyungcheol; Smith, Colin I.; Fuller, Benjamin T.; Richards, Michael P.

    2010-11-01

    This research presents the individual amino acid δ 13C values in bone collagen of humans ( n = 9) and animals ( n = 27) from two prehistoric shell midden sites in Korea. We obtained complete baseline separation of 16 of the 18 amino acids found in bone collagen by using liquid chromatography-isotope ratio mass spectrometry (LC-IRMS). The isotopic results reveal that the humans and animals in the two sites had similar patterns in essential amino acids (EAAs) and non-essential amino acids (NEAAs). The EAA and NEAA δ 13C values in humans are intermediate between those in marine and terrestrial animals. However, the threonine δ 13C values in humans and animals measured in this study are more highly enriched than those of other amino acids. At both sites, all amino acids in marine animals are 13C-enriched relative to those of the terrestrial animals. The isotopic evidence suggests that the Tongsamdong human had EAAs and NEAAs from marine food resources, while the Nukdo humans mainly had EAAs from terrestrial food resources but obtained NEAAs from both terrestrial and marine resources. The δ 13C isotopic differences in amino acids between marine and terrestrial animals were the largest for glycine (NEAA) and histidine (EAA) and the smallest for tyrosine (NEAA) and phenylalanine (EAA). In addition, threonine among the EAAs also had a large difference (˜8‰) in δ 13C values between marine and terrestrial animals, and has the potential to be used as an isotopic marker in palaeodietary studies. Threonine δ 13C values were used in conjunction with the established Δ 13C Glycine-phenylalanine values and produced three distinct dietary groups (terrestrial, omnivorous, and marine). In addition, threonine δ 13C values and Δ 13C Serine-phenylalanine values were discovered to separate between two dietary groups (terrestrial vs. marine), and these δ 13C values may provide a potential new indicator for investigating the distinction between marine and terrestrial protein

  6. LabData database sub-systems for post-processing and quality control of stable isotope and gas chromatography measurements

    Science.gov (United States)

    Suckow, A. O.

    2013-12-01

    Measurements need post-processing to obtain results that are comparable between laboratories. Raw data may need to be corrected for blank, memory, drift (change of reference values with time), linearity (dependence of reference on signal height) and normalized to international reference materials. Post-processing parameters need to be stored for traceability of results. State of the art stable isotope correction schemes are available based on MS Excel (Geldern and Barth, 2012; Gröning, 2011) or MS Access (Coplen, 1998). These are specialized to stable isotope measurements only, often only to the post-processing of a special run. Embedding of algorithms into a multipurpose database system was missing. This is necessary to combine results of different tracers (3H, 3He, 2H, 18O, CFCs, SF6...) or geochronological tools (Sediment dating e.g. with 210Pb, 137Cs), to relate to attribute data (submitter, batch, project, geographical origin, depth in core, well information etc.) and for further interpretation tools (e.g. lumped parameter modelling). Database sub-systems to the LabData laboratory management system (Suckow and Dumke, 2001) are presented for stable isotopes and for gas chromatographic CFC and SF6 measurements. The sub-system for stable isotopes allows the following post-processing: 1. automated import from measurement software (Isodat, Picarro, LGR), 2. correction for sample-to sample memory, linearity, drift, and renormalization of the raw data. The sub-system for gas chromatography covers: 1. storage of all raw data 2. storage of peak integration parameters 3. correction for blank, efficiency and linearity The user interface allows interactive and graphical control of the post-processing and all corrections by export to and plot in MS Excel and is a valuable tool for quality control. The sub-databases are integrated into LabData, a multi-user client server architecture using MS SQL server as back-end and an MS Access front-end and installed in four

  7. Analytical approach for the determination of steroid profile of humans by gas chromatography isotope ratio mass spectrometry aimed at distinguishing between endogenous and exogenous steroids.

    Science.gov (United States)

    Bulska, Ewa; Gorczyca, Damian; Zalewska, Izabela; Pokrywka, Andrzej; Kwiatkowska, Dorota

    2015-03-15

    The contamination of commonly used supplements by unknown steroids as well as their metabolites (parent compounds) become a challenge for the analytical laboratories. Although the determination of steroids profile is not trivial because of the complex matrix and low concentration of single compound, one of the most difficult current problem is to distinguish, during analytical procedure, endogenous androgens such as testosterone, dehydrotestosterone or dehydroepiandrosterone from their synthetic equivalents. The aim of this work was to develop and validate an analytical procedure for determination of the steroid profile in human urine by gas chromatography-combustion-isotope ratio mass spectrometry (GC/C/IRMS) toward distinguishing between endogenous and exogenous steroids. Beside the optimization of the experimental parameters for gas chromatography separation and mass spectrometry, attention was focused on urine sample preparation. Using an optimized sample preparation protocol it was possible to achieve better chromatographic resolutions and better sensitivity enabling the determination of 5 steroids, androsterone, etiocholanolone, testosterone, 5-androstandiol, 11-hydroxyandrdostane, pregnandiol, with the expanded uncertainty (k=2) below 1‰. This enable to evaluate the significant shift of the δ(13)C/(12)C [‰] values for each of examined steroids (excluding ERC). The analytical protocol described in this work was successfully used for the confirmation of positive founding urine by evaluation T/E ratio after GC/C/IRMS analysis.

  8. Characterization and quantification of histidine degradation in therapeutic protein formulations by size exclusion-hydrophilic interaction two dimensional-liquid chromatography with stable-isotope labeling mass spectrometry.

    Science.gov (United States)

    Wang, Chunlei; Chen, Sike; Brailsford, John A; Yamniuk, Aaron P; Tymiak, Adrienne A; Zhang, Yingru

    2015-12-24

    Two dimensional liquid chromatography (2D-LC) coupling size exclusion (SEC) and hydrophilic interaction chromatography (HILIC) is demonstrated as a useful tool to study polar excipients, such as histidine and its degradant, in protein formulation samples. The SEC-HILIC setup successfully removed interferences from complex sample matrices and enabled accurate mass measurement of the histidine degradation product, which was then determined to be trans-urocanic acid. Because the SEC effluent is a strong solvent for the second dimension HILIC, experimental parameters needed to be carefully chosen, i.e., small transferring loop, fast gradient at high flow rates for the second dimension gradient, in order to mitigate the solvent mismatch and to ensure good peak shapes for HILIC separations. In addition, the generation of trans-urocanic acid was quantified by single heart-cutting SEC-HILIC 2D-LC combined with stable-isotope labeling mass spectrometry. Compared with existing 2D quantification methods, the proposed approach is fast, insensitive to solvent mismatch between dimensions, and tolerant of small retention time shifts in the first dimension. Finally, the first dimension diode array detector was found to be a potential degradation source for photolabile analytes such as trans-urocanic acid.

  9. A New Approach to Determine the Total Airborne N Input into the Soil/Plant System Using 15N Isotope Dilution (ITNI: Results for Agricultural Areas in Central Germany

    Directory of Open Access Journals (Sweden)

    Rolf W.B. Russow

    2001-01-01

    Full Text Available The atmospheric deposition of nitrogen (N in the environment is of great concern due to its impact on natural ecosystems including affecting vegetation, reducing biodiversity, increasing tree growth in forests, and the eutrophication of aquatic systems. Taking into account the average annual N emission into the atmosphere in Germany of about 2 million t N (ammonia/ammonium, NOx, and assuming homogeneous distribution throughout Germany, an average N deposition of 45 kg/ha x year can be calculated. Such high atmospheric N deposition could be confirmed by N balances from long-term field experiments in Central Germany (e.g., the Static Fertilization Experiment in Bad Lauchstädt. By contrast, estimates by standard methods indicate a deposition of only about 30 kg N/ha x year. This is because the standard methods are using wet-only or bulk collectors, which fail to take into account gaseous deposition and the direct uptake of atmospheric N by aerial plant parts. Therefore, a new system was developed using 15N isotope dilution methodology to measure the actual total atmospheric N input into a soil/plant system (Integrated Total Nitrogen Input, ITNI. A soil/plant system is labeled with [15N]ammonium-[15N]nitrate and the total input of airborne N is calculated from the dilution of this tracer by N from the atmosphere. An average annual deposition of 64 ± 11 kg/ha x year from 1994–2000 was measured with the ITNI system at the Bad Lauchst?dt research farm in the dry belt of Central Germany. Measurements in 1999/2000 at three other sites in Central Germany produced deposition rates of about 60 kg/ha x year. These data clearly show that the total atmospheric N deposition into the soil/plant system determined by the newly developed ITNI system significantly exceeds that obtained from standard wet-only and bulk collectors. The higher atmospheric N depositions found closely match those postulated from the N balances of long-term agricultural field

  10. Quantitative analysis of phosphoric acid esters in aqueous samples by isotope dilution stir-bar sorptive extraction combined with direct analysis in real time (DART)-Orbitrap mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Bridoux, Maxime C., E-mail: maxime.bridoux@cea.fr [CEA, DAM, DIF, F-91297 Arpajon (France); Malandain, Hélène [SANTEN SAS, 1 rue Pierre Fontaine, Bâtiment Genavenir IV, F-91058 Evry (France); Leprince, Françoise; Progent, Frédéric; Machuron-Mandard, Xavier [CEA, DAM, DIF, F-91297 Arpajon (France)

    2015-04-15

    Highlights: • Theory and modeling of organophosphorus SBSE extraction are presented. • Organophosphorus are quantitatively analyzed by isotopic dilution SBSE/DART/Orbitrap-MS. • PDMS coated Twisters™ extract phosphate acid esters in the neutral form from water samples. • Good linearity between concentrations and relative peak areas (0.1–750 ng mL{sup −1}). • This novel SBSE/DART/Orbitrap-MS method should be very valuable for on-site sampling/monitoring - Abstract: A novel hyphenated technique, namely the combination of stir bar sorptive extraction (SBSE) with isotope dilution direct analysis in real time (DART) Orbitrap™ mass spectrometry (OT-MS) is presented for the extraction of phosphoric acid alkyl esters (tri- (TnBP), di- (HDBP), and mono-butyl phosphate (H2MBP)) from aqueous samples. First, SBSE of phosphate esters was performed using a Twister™ coated with 24 μL of polydimethylsiloxane (PDMS) as the extracting phase. SBSE was optimized for extraction pH, phase ratio (PDMS volume/aqueous phase volume), stirring speed, extraction time and temperature. Then, coupling of SBSE to DART/Orbitrap-MS was achieved by placing the Twister™ in the middle of an open-ended glass tube between the DART and the Orbitrap™. The DART mass spectrometric response of phosphate esters was probed using commercially available and synthesized alkyl phosphate ester standards. The positive ion full scan spectra of alkyl phosphate triesters (TnBP) was characterized by the product of self-protonation [M + H]{sup +} and, during collision-induced dissociation (CID), the major fragmentation ions corresponded to consecutive loss of alkyl chains. Negative ionization gave abundant [M − H]{sup −} ions for both HDnBP and H2MnBP. Twisters™ coated with PDMS successfully extracted phosphate acid esters (tri-, di- and mono-esters) granted that the analytes are present in the aqueous solution in the neutral form. SBSE/DART/Orbitrap-MS results show a good linearity between

  11. Measurement of alpha-tocopherol turnover in plasma and in lipoproteins using stable isotopes and gas chromatography/mass spectrometry.

    Science.gov (United States)

    Parks, Elizabeth J

    2002-01-01

    Burton and Daroszewska (16) have presented an excellent method for quantifying alpha-tocopherol in human and animal tissues. The present paper expands that method by including the theory and calculations for alpha-tocopherol turnover in human plasma and lipoprotein fractions. Recent advances in mathematical modeling in experimental nutrition (22) have been aided by the increased availability of labeled isotopes and sensitive analytical methods. Applied to the study of alpha-tocopherol, these techniques will allow the characterization of the kinetic behavior of this micronutrient in vivo and expand the understanding of this key nutrient's role in preventing disease.

  12. Separation processes using expulsion from dilute supercritical solutions

    Science.gov (United States)

    Cochran, Jr., Henry D.

    1993-01-01

    A process for separating isotopes as well as other mixtures by utilizing the behavior of dilute repulsive or weakly attractive elements of the mixtures as the critical point of the solvent is approached.

  13. Development of an accurate, sensitive, and robust isotope dilution laser ablation ICP-MS method for simultaneous multi-element analysis (chlorine, sulfur, and heavy metals) in coal samples.

    Science.gov (United States)

    Boulyga, Sergei F; Heilmann, Jens; Prohaska, Thomas; Heumann, Klaus G

    2007-10-01

    A method for the direct multi-element determination of Cl, S, Hg, Pb, Cd, U, Br, Cr, Cu, Fe, and Zn in powdered coal samples has been developed by applying inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with laser-assisted introduction into the plasma. A sector-field ICP-MS with a mass resolution of 4,000 and a high-ablation rate laser ablation system provided significantly better sensitivity, detection limits, and accuracy compared to a conventional laser ablation system coupled with a quadrupole ICP-MS. The sensitivity ranges from about 590 cps for (35)Cl+ to more than 6 x 10(5) cps for (238)U+ for 1 microg of trace element per gram of coal sample. Detection limits vary from 450 ng g(-1) for chlorine and 18 ng g(-1) for sulfur to 9.5 pg g(-1) for mercury and 0.3 pg g(-1) for uranium. Analyses of minor and trace elements in four certified reference materials (BCR-180 Gas Coal, BCR-331 Steam Coal, SRM 1632c Trace Elements in Coal, SRM 1635 Trace Elements in Coal) yielded good agreement of usually not more than 5% deviation from the certified values and precisions of less than 10% relative standard deviation for most elements. Higher relative standard deviations were found for particular elements such as Hg and Cd caused by inhomogeneities due to associations of these elements within micro-inclusions in coal which was demonstrated for Hg in SRM 1635, SRM 1632c, and another standard reference material (SRM 2682b, Sulfur and Mercury in Coal). The developed LA-ICP-IDMS method with its simple sample pretreatment opens the possibility for accurate, fast, and highly sensitive determinations of environmentally critical contaminants in coal as well as of trace impurities in similar sample materials like graphite powder and activated charcoal on a routine basis.

  14. The application of isotopic ({sup 32}P and {sup 15}N) dilution techniques to evaluate the interactive effect of phosphate-solubilizing rhizobacteria, mycorrhizal fungi and Rhizobium to improve the agronomic efficiency of rock phosphate for legume crops

    Energy Technology Data Exchange (ETDEWEB)

    Barea, J.M. [Departamento de Microbiologia del Suelo y Sistemas Simbioticos (Spain)]. E-mail: jmbarea@eez.csic.es; Toro, M.; Azcon, R. [Departamento de Microbiologia del Suelo y Sistemas Simbioticos (Spain); Orozco, M.O. [Instituto de Sistematica y Ecologia, Academia Cubana de Ciencias, Habana (Cuba); Campos, E. [Departamento de Ciencias de la Tierra y Quimica Ambiental Estacion Experimental del Zaidin (CSIC), Granada (Spain); Azcon, R. [Departamento de Microbiologia del Suelo y Sistemas Simbioticos (Spain)

    2002-05-15

    A pot experiment was designed to evaluate the interactive effects of multifunctional microbial inoculation treatments and rock phosphate (RP) application on N and P uptake by alfalfa through the use of {sup 15}N and {sup 32}P isotopic dilution approaches. The microbial inocula consisted of a wild type (WT) Rhizobium meliloti strain, the arbuscular mycorrhizal (AM) fungus Glomus mosseae (Nicol. and Gerd.) Gerd. and Trappe, and a phosphate solubilizing rhizobacterium (Enterobacter sp.). Inoculated microorganisms were established in the root tissues and/or in the rhizosphere soil of alfalfa plants (Medicago sativa L.). Improvements in N and P accumulation in alfalfa corroborate beneficial effects of Rhizobium and AM interactions. Inoculation with selected rhizobacteria improved the AM effect on N or P accumulation in both the RP-added soil and in the non RP-amended controls. Measurements of the {sup 15}N/{sup 14}N ratio in plant shoots indicate an enhancement of the N{sub 2} fixation rates in Rhizobium-inoculated AM-plants, over that achieved by Rhizobium in non-mycorrhizal plants. Whether or not RP was added, AM-inoculated plants showed a lower specific activity ({sup 32}P/{sup 31}P) than did their comparable non-mycorrhizal controls, suggesting that the plant was using otherwise unavailable P sources. The phosphate-solubilizing, AM-associated, microbiota could in fact release phosphate ions, either from the added RP or from the indigenous 'less-available' soil phosphate. A low Ca concentrations in the test soil may have benefited P solubilization. Under field conditions, the inoculation with AM fungi significantly increased plant biomass and N and P accumulation in plant tissues. Phosphate-solubilizing rhizobacteria improved mycorrhizal responses in soil dually receiving RP and organic matter amendments. Organic matter addition favoured RP solubilization. This, together with a tailored microbial inoculation, increased the agronomic efficiency of RP in the

  15. External calibration in gas chromatography-combustion-isotope ratio mass spectrometry measurements of endogenous androgenic anabolic steroids in sports doping control.

    Science.gov (United States)

    Kioussi, Maroula K; Angelis, Yiannis S; Cawley, Adam T; Koupparis, Michalis; Kazlauskas, Rymantas; Brenna, J Thomas; Georgakopoulos, Costas G

    2011-08-19

    An alternative calibration procedure for the gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS) measurements of the World Antidoping Agency (WADA) Accredited Laboratories is presented. To alleviate the need for externally calibrated CO₂ gas for GC-C-IRMS analysis of urinary steroid metabolites, calibration using an external standard mixture solution of steroids with certified isotopic composition was investigated. The reference steroids of the calibration mixture and routine samples underwent identical instrumental processes. The calibration standards bracketed the entire range of the relevant δ¹³C values for the endogenous and exogenous steroids as well as their chromatographic retention times. The certified δ¹³C values of the reference calibrators were plotted in relation to measured m/z ¹³CO₂/¹²CO₂ (i.e. R(45/44)) mass spectrometric signals of each calibrator. δ¹³C values of the sample steroids were calculated from the least squares fit through the calibration curve. The effect of the external calibration on δ¹³C values, using the same calibration standards and set of urine samples but different brands of GC-C-IRMS instruments, was assessed by an interlaboratory study in the WADA Accredited Laboratories of Sydney, Australia and Athens, Greece. Relative correspondence between the laboratories for determination of androsterone, etiocholanolone, 5β-androstane-3α,17β-diacetate, and pregnanediacetate means were SD(δ¹³C)=0.12‰, 0.58‰, -0.34‰, and -0.40‰, respectively. These data demonstrate that accurate intralaboratory external calibration with certified steroids provided by United States Antidoping Agency (USADA) and without external CO₂ calibration is feasible and directly applicable to the WADA Accredited Laboratories for the harmonization of the GC-C-IRMS measurements.

  16. Quantitative analysis of aberrant fatty acid composition of zebrafish hepatic lipids induced by organochlorine pesticide using stable isotope-coded transmethylation and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Zhong, Hongying; Dong, Linjie; Dong, Qingjian; Ke, Changshu; Fu, Jieying; Wang, Xiaoli; Liu, Cong; Dai, Ling

    2012-07-01

    Organochlorine pesticides have been extensively used worldwide for agricultural purposes. Due to their resistance to metabolism, a major public health concern has been raised. Aberrant hepatic lipid composition has been a hallmark of many liver diseases associated with exposure to various toxins and chemicals. And thus lots of efforts have been focused on the development of analytical techniques that can rapidly and quantitatively determine the changes in fatty acid composition of hepatic lipids. In this work, changes in fatty acid composition of hepatic lipids in response to DDT (dichlorodiphenyltrichloroethane) exposure were quantitatively analyzed by a gas chromatography-mass spectrometric approach based on stable isotope-coded transmethylation. It has been quantitatively demonstrated that polyunsaturated fatty acids including C20:3n3, C20:4n6, and C22:6n3 decrease in response to DDT exposure. However, saturated long chain fatty acids including C16:0, C18:0, as well as monounsaturated long chain fatty acid C18:1n9 consistently increase in a DDT-concentration-dependent manner. In particular, much higher changes in the level of hepatic C16:0 and C18:0 for male fish were observed than that for female fish. These experimental results are in accordance with qualitative histopathological analysis that revealed liver morphological alterations. The stable isotope-coded mass spectrometric approach provides a reliable means for investigating hepatotoxicity associated with fatty acid synthesis, desaturation, mitochondrial beta-oxidation, and lipid mobilization. It should be useful in elucidation of hepatotoxic mechanisms and safety assessment of environmental toxins.

  17. Analysis of cytochrome P450 metabolites of arachidonic acid by stable isotope probe labeling coupled with ultra high-performance liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Zhu, Quan-Fei; Hao, Yan-Hong; Liu, Ming-Zhou; Yue, Jiang; Ni, Jian; Yuan, Bi-Feng; Feng, Yu-Qi

    2015-09-04

    Cytochrome P450 metabolites of arachidonic acid (AA) belong to eicosanoids and are potent lipid mediators of inflammation. It is well-known that eicosanoids play an important role in numerous pathophysiological processes. Therefore, quantitative analysis of cytochrome P450 metabolites of AA, including hydroxyeicosatetraenoic acids (HETEs), epoxyeicosatreinoic acids (EETs), and dihydroxyeicosatrienoic acids (DHETs) can provide crucial information to uncover underlying mechanisms of cytochrome P450 metabolites of AA related diseases. Herein, we developed a highly sensitive method to identify and quantify HETEs, EETs, and DHETs in lipid extracts of biological samples based on stable isotope probe labeling coupled with ultra high-performance liquid chromatography/mass spectrometry. To this end, a pair of stable isotope probes, 2-dimethylaminoethylamine (DMED) and d4-2-dimethylaminoethylamine (d4-DMED), were utilized to facilely label eicosanoids. The heavy labeled eicosanoid standards were prepared and used as internal standards for quantification to minimize the matrix and ion suppression effects in mass spectrometry analysis. In addition, the detection sensitivities of DMED labeled eicosanoids improved by 3-104 folds in standard solution and 5-138 folds in serum matrix compared with unlabeled analytes. Moreover, a good separation of eicosanoids isomers was achieved upon DMED labeling. The established method provided substantial sensitivity (limit of quantification at sub-picogram), high specificity, and broad linear dynamics range (3 orders of magnitude). We further quantified cytochrome P450 metabolites of AA in rat liver, heart, brain tissues and human serum using the developed method. The results showed that 19 eicosanoids could be distinctly detected and the contents of 11-, 15-, 16-, 20-HETE, 5,6-EET, and 14,15-EET in type 2 diabetes mellitus patients and 5-, 11-, 12-, 15-, 16-, 20-HETE, 8,9-EET, and 5,6-DHET in myeloid leukemia patients had significant changes

  18. Use of stable isotope labeled probes to facilitate liquid chromatography/mass spectrometry based high-throughput screening of time-dependent CYP inhibitors.

    Science.gov (United States)

    Dasgupta, Malini; Tang, Weimin; Caldwell, Gary W; Yan, Zhengyin

    2010-08-15

    Inhibition curve shift is a commonly used approach for screening of time-dependent CYP inhibitors which requires parallel paired incubations to obtain two inhibition curves for comparison. For the control incubation, a test compound is co-incubated with a probe substrate in human liver microsomes (HLM) fortified with NADPH; for the time-dependent incubation (TDI), the test compound is pre-incubated with NADPH-fortified HLM followed by a secondary incubation with a probe substrate. For both incubations, enzyme activity is measured respectively by liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis of the CYP-specific metabolite, and a TDI inhibitor can be readily identified by inhibition curve shifting as a result of CYP inactivation by the test compound during the pre-incubation. In the present study, we describe an alternative approach to facilitate TDI screening in which stable isotope labeled CYP-specific probes are used for the TDI, and non-labeled substrates are included in the control incubation. Because CYP-specific metabolites produced in the TDI are stable isotope labeled, two sets of incubation samples can be combined and then simultaneously analyzed by LC/MS/MS in the same batch run to reduce the run time. This new method has been extensively validated using both a number of known competitive and TDI inhibitors specific to five most common CYPs such as 1A2, 2C9, 2C19, 2D6, and 3A4. The assay is performed in a 96-well format and can be fully automated. Compared to the traditional method, this approach in combination with sample pooling and a short LC/MS/MS gradient significantly enhances the throughput of TDI screening and thus can be easily implemented in drug discovery to evaluate a large number of compounds without adding additional resource.

  19. Development of an analytical method for the determination of the misuse in sports of boldenone through the analysis of urine by on-line coupling liquid chromatography-gas chromatography-combustion-isotope ratio mass spectrometry.

    Science.gov (United States)

    Toledano, R M; Díaz-Plaza, E M; Cortes, J M; Aragón, A; Vázquez, A M; Villén, J; Muñoz-Guerra, J

    2014-11-28

    Boldenone (Bo), androsta-1,4-dien-17β-ol-3-one, is an anabolic androgenic steroid not clinically approved for human application. Despite this, many cases are reported every year of athletes testing positive for Bo or its main metabolite 5β-androst-1-en-17β-ol-3-one (BoM). Recently the capability of different human intestinal bacteria to produce enzymes able to modify endogenous steroids in Bo has been demonstrated. When a urinary concentration of Bo and/or BoM between 5 and 30 ng/mL is measured a complementary analysis by gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS) must be carried out to discriminate the endogenous or exogenous origin. In the present work, a novel analytical method that couples LC-GC by means of the TOTAD interface with C-IRMS is described. The method is based on a first RPLC separation of unacetyled steroids, followed by acetylation and automated on-line LC-GC-C-IRMS, which includes a second RPLC clean-up of acetyl Bo and BoM, isolation of the two fractions in a fraction collector and their consecutive analysis by GC-C-IRMS. The method has been applied to the analysis of urine samples fortified at 5 and 10 ng/mL, where it has shown a good performance.

  20. Determination of 13C isotopic enrichment of glutathione and glycine by gas chromatography/combustion/isotope ratio mass spectrometry after formation of the N- or N,S-ethoxycarbonyl methyl ester derivatives.

    Science.gov (United States)

    Tea, Illa; Ferchaud-Roucher, Véronique; Küster, Alice; Darmaun, Dominique; Robins, Richard J

    2007-01-01

    The depletion of glutathione (GSH) reported in very-low-birth-weight infants is implicated in several pathologies, especially if deficiency occurs during foetal development. The cause of this depletion is suggested to be modification of GSH turnover. To probe the role of GSH, a reliable non-invasive method adapted to very-low-birth-weight infants is required. In this paper, we report the preparation of the N,S-ethoxycarbonyl methyl ester derivatives of GSH and glycine and their application to the measurement of (13)C/(12)C ratios at natural abundance in erythrocyte samples by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). The technique allowed the determination of (13)C/(12)C ratios at natural abundance with a precision synthesis rate (FSR) in human adult blood (approx. 300% day(-1)) using the low-enrichment (13)C-glycine/GC/C/IRMS protocol and that using highly enriched (13)C-glycine (99 atom %)/GC/MS with the same derivative. The GC/C/IRMS method was shown to be suitable to measure the in vitro GSH FSR (200-660% day(-1)) in human venous and arterial blood from the umbilical cord. This approach provides a good tool for studying the turnover of GSH in vitro in infants, allowing both the use of minimal amounts of tracer and negligible perturbation of endogenous precursor pools.

  1. Absolute quantification of Pru av 2 in sweet cherry fruit by liquid chromatography/tandem mass spectrometry with the use of a stable isotope-labelled peptide.

    Science.gov (United States)

    Ippoushi, Katsunari; Sasanuma, Motoe; Oike, Hideaki; Kobori, Masuko; Maeda-Yamamoto, Mari

    2016-08-01

    Pru av 2, a pathogenesis-related (PR) protein present in the sweet cherry (Prunus avium L.) fruit, is the principal allergen of cherry and one of the chief causes of pollen food syndrome (oral allergy syndrome). In this study, a quantitative assay for this protein was developed with the use of the protein absolute quantification (AQUA) method, which consists of liquid chromatography/tandem mass spectrometry (LC/MS/MS) employing TGC[CAM]STDASGK[(13)C6,(15)N2], a stable isotope-labelled internal standard (SIIS) peptide. This assay gave a linear relationship (r(2)>0.99) in a concentration range (2.3-600fmol/μL), and the overall coefficient of variation (CV) for multiple tests was 14.6%. Thus, the contents of this allergenic protein in sweet cherry products could be determined using this assay. This assay should be valuable for allergological investigations of Pru av 2 in sweet cherry and detection of protein contamination in foods. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Gas Purge Microextraction Coupled with Stable Isotope Labeling-Liquid Chromatography/Mass Spectrometry for the Analysis of Bromophenols in Aquatic Products.

    Science.gov (United States)

    Zhang, Shijuan; Yu, Qiuhui; Sheng, Cuncun; You, Jinmao

    2016-12-14

    A green, sensitive, and accurate method was developed for the extraction and determination of bromophenols (BPs) from aquatic products by using organic solvent-free gas purge microsyringe extraction (GP-MSE) technique in combination with stable isotope labeling (SIL) strategy. BPs were extracted by NaHCO3 buffer solution, with recoveries varying from 92.0% to 98.5%. The extracted solution was analyzed by SIL strategy, during which analytes and standards were labeled by 10-methyl-acridone-2-sulfonyl chloride (d0-MASC) and its deuterated counterpart d3-MASC, respectively. The labeling reaction was finished within 10 min with good stability. The liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) sensitivity of BPs was greatly enhanced due to the mass-enhancing property of MASC, while the matrix effect was effectively minimized by the SIL strategy. The limits of detection (LODs) were in the range of 0.10-0.30 μg/kg, while the limits of quantitations (LOQs) were in the range of 0.32-1.0 μg/kg. The proposed method also showed great potential in the qualitative analysis of other bromophenols in the absence of standard.

  3. Universal quantitative kinase assay based on diagonal SCX chromatography and stable isotope dimethyl labeling provides high-definition kinase consensus motifs for PKA and human Mps1.

    Science.gov (United States)

    Hennrich, Marco L; Marino, Fabio; Groenewold, Vincent; Kops, Geert J P L; Mohammed, Shabaz; Heck, Albert J R

    2013-05-01

    In order to understand cellular signaling, a clear understanding of kinase-substrate relationships is essential. Some of these relationships are defined by consensus recognition motifs present in substrates making them amendable for phosphorylation by designated kinases. Here, we explore a method that is based on two sequential steps of strong cation exchange chromatography combined with differential stable isotope labeling, to define kinase consensus motifs with high accuracy. We demonstrate the value of our method by evaluating the motifs of two very distinct kinases: cAMP regulated protein kinase A (PKA) and human monopolar spindle 1 (Mps1) kinase, also known as TTK. PKA is a well-studied basophilic kinase with a relatively well-defined motif and numerous known substrates in vitro and in vivo. Mps1, a kinase involved in chromosome segregation, has been less well characterized. Its substrate specificity is unclear and here we show that Mps1 is an acidophilic kinase with a striking tendency for phosphorylation of threonines. The final outcomes of our work are high-definition kinase consensus motifs for PKA and Mps1. Our generic method, which makes use of proteolytic cell lysates as a source for peptide-substrate libraries, can be implemented for any kinase present in the kinome.

  4. Innovative method for carbon dioxide determination in human postmortem cardiac gas samples using headspace-gas chromatography-mass spectrometry and stable labeled isotope as internal standard.

    Science.gov (United States)

    Varlet, V; Smith, F; de Froidmont, S; Dominguez, A; Rinaldi, A; Augsburger, M; Mangin, P; Grabherr, S

    2013-06-19

    A novel approach to measure carbon dioxide (CO2) in gaseous samples, based on a precise and accurate quantification by (13)CO2 internal standard generated in situ is presented. The main goal of this study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable in the routine determination of CO2. The main drawback of the GC methods discussed in the literature for CO2 measurement is the lack of a specific internal standard necessary to perform quantification. CO2 measurement is still quantified by external calibration without taking into account analytical problems which can often occur considering gaseous samples. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in situ an internal labeled standard gas ((13)CO2) on the basis of the stoichiometric formation of CO2 by the reaction of hydrochloric acid (HCl) with sodium hydrogen carbonate (NaH(13)CO3). This method allows a precise measurement of CO2 concentration and was validated on various human postmortem gas samples in order to study its efficiency. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. High-accuracy determination of iron in seawater by isotope dilution multiple collector inductively coupled plasma mass spectrometry (ID-MC-ICP-MS) using nitrilotriacetic acid chelating resin for pre-concentration and matrix separation

    Energy Technology Data Exchange (ETDEWEB)

    Jong, Jeroen de [Universite Libre de Bruxelles (ULB), Departement des Sciences de la Terre et de l' Environnement (DSTE), Unite Isotopes: Petrologie et Environnement - IPE CP 160/02, Avenue F.D. Roosevelt 50, B-1050 Brussels (Belgium)], E-mail: jdejong@ulb.ac.be; Schoemann, Veronique [Universite Libre de Bruxelles (ULB), Ecologie des Systemes Aquatiques (ESA) CP 221, Avenue F.D. Roosevelt 50, B-1050 Brussels (Belgium); Lannuzel, Delphine [Universite Libre de Bruxelles (ULB), Departement des Sciences de la Terre et de l' Environnement (DSTE), Laboratoire d' Oceanographie Chimique et Geochimie des Eaux - LOCGE CP 208, Avenue F.D. Roosevelt 50, B-1050 Brussels (Belgium); Tison, Jean-Louis [Universite Libre de Bruxelles (ULB), Departement des Sciences de la Terre et de l' Environnement (DSTE), Laboratoire de Glaciologie - GLACIOL CP 160/03, Avenue F.D. Roosevelt 50, B-1050 Brussels (Belgium); Mattielli, Nadine [Universite Libre de Bruxelles (ULB), Departement des Sciences de la Terre et de l' Environnement (DSTE), Unite Isotopes: Petrologie et Environnement - IPE CP 160/02, Avenue F.D. Roosevelt 50, B-1050 Brussels (Belgium)

    2008-08-15

    In the present paper we describe a robust and simple method to measure dissolved iron (DFe) concentrations in seawater down to <0.1 nmol L{sup -1} level, by isotope dilution multiple collector inductively coupled plasma mass spectrometry (ID-MC-ICP-MS) using a {sup 54}Fe spike and measuring the {sup 57}Fe/{sup 54}Fe ratio. The method provides for a pre-concentration step (100:1) by micro-columns filled with the resin NTA Superflow of 50 mL seawater samples acidified to pH 1.9. NTA Superflow is demonstrated to quantitatively extract Fe from acidified seawater samples at this pH. Blanks are kept low (grand mean 0.045 {+-} 0.020 nmol L{sup -1}, n = 21, 3x S.D. limit of detection per session 0.020-0.069 nmol L{sup -1} range), as no buffer is required to adjust the sample pH for optimal extraction, and no other reagents are needed than ultrapure nitric acid, 12 mM H{sub 2}O{sub 2}, and acidified (pH 1.9) ultra-high purity (UHP) water. We measured SAFe (sampling and analysis of Fe) reference seawater samples Surface-1 (0.097 {+-} 0.043 nmol L{sup -1}) and Deep-2 (0.91 {+-} 0.17 nmol L{sup -1}) and obtained results that were in excellent agreement with their DFe consensus values: 0.118 {+-} 0.028 nmol L{sup -1} (n = 7) for Surface-1 and 0.932 {+-} 0.059 nmol L{sup -1} (n = 9) for Deep-2. We also present a vertical DFe profile from the western Weddell Sea collected during the Ice Station Polarstern (ISPOL) ice drift experiment (ANT XXII-2, RV Polarstern) in November 2004-January 2005. The profile shows near-surface DFe concentrations of {approx}0.6 nmol L{sup -1} and bottom water enrichment up to 23 nmol L{sup -1} DFe.

  6. Using 15N isotopic dilution method to quantify the biological nitrogen fixation in sugarcane%15N同位素稀释法评估甘蔗的生物固氮量

    Institute of Scientific and Technical Information of China (English)

    周晓舟; 李杨瑞; 杨丽涛

    2012-01-01

    The quantification of biological nitrogen fixation in sugarcane was investigated with 15N isotope dilution technique in greenhouse bucket culture test,using cassava as reference plant. The experimental results showed that Ndfa accounted for 11. 3514%,and the nitrogen fixation rate was 0. 9269 g/bucket for whole growth duration of sugarcane. Ndfa and the nitrogen fixation amount in different organs of the plant showed leaf>stalk>root. Ndfa in leaf accounted for 13. 2668%,a little higher than that in the whole plant,but the difference was not significant. The percentage of nitrogen from air,fertilizer and soil occupying the total nitrogen of the plant was 11. 3514% ,7. 6857% and 80. 9629%, respectively. The nitrogen use efficiency of sugarcane was 58. 7583%. It was concluded that all organs of sugarcane could fix nitrogen through biological nitrogen fixation,and leaves could be used to estimate the amount of biological nitrogen fixation in place of whole plant of sugarcane.%为评估甘蔗生物固氮量,采用15N同位素稀释法,以木薯为参比植物,进行温室桶栽试验.结果表明:甘蔗全生育期植株固氮11.3514% Ndfa,固氮量每桶0.9269 g.甘蔗根、茎、叶的固氮百分率和固氮量大小依序为叶>茎>根.叶的固氮百分率(13.2668% Ndfa)略高于植株,但两者差异不显著.甘蔗植株全氮量中来自空气氮(生物固氮)、肥料氮和土壤氮的比例分别为11.3514%、7.6857%、80.9629%.甘蔗的氮肥利用率为58.7583%.甘蔗根、茎、叶各部位均有固氮现象,生产上可以用叶代替植株来评估甘蔗的生物固氮量.

  7. Development of an accurate, sensitive, and robust isotope dilution laser ablation ICP-MS method for simultaneous multi-element analysis (chlorine, sulfur, and heavy metals) in coal samples

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, Sergei F. [University of Natural Resources and Applied Life Sciences, Department of Chemistry, Division of Analytical Chemistry-VIRIS Laboratory, Vienna (Austria); Johannes Gutenberg-University, Institute of Inorganic Chemistry and Analytical Chemistry, Mainz (Germany); Heilmann, Jens; Heumann, Klaus G. [Johannes Gutenberg-University, Institute of Inorganic Chemistry and Analytical Chemistry, Mainz (Germany); Prohaska, Thomas [University of Natural Resources and Applied Life Sciences, Department of Chemistry, Division of Analytical Chemistry-VIRIS Laboratory, Vienna (Austria)

    2007-10-15

    A method for the direct multi-element determination of Cl, S, Hg, Pb, Cd, U, Br, Cr, Cu, Fe, and Zn in powdered coal samples has been developed by applying inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with laser-assisted introduction into the plasma. A sector-field ICP-MS with a mass resolution of 4,000 and a high-ablation rate laser ablation system provided significantly better sensitivity, detection limits, and accuracy compared to a conventional laser ablation system coupled with a quadrupole ICP-MS. The sensitivity ranges from about 590 cps for {sup 35}Cl{sup +} to more than 6 x 10{sup 5} cps for {sup 238}U{sup +} for 1 {mu}g of trace element per gram of coal sample. Detection limits vary from 450 ng g{sup -1} for chlorine and 18 ng g{sup -1} for sulfur to 9.5 pg g{sup -1} for mercury and 0.3 pg g{sup -1} for uranium. Analyses of minor and trace elements in four certified reference materials (BCR-180 Gas Coal, BCR-331 Steam Coal, SRM 1632c Trace Elements in Coal, SRM 1635 Trace Elements in Coal) yielded good agreement of usually not more than 5% deviation from the certified values and precisions of less than 10% relative standard deviation for most elements. Higher relative standard deviations were found for particular elements such as Hg and Cd caused by inhomogeneities due to associations of these elements within micro-inclusions in coal which was demonstrated for Hg in SRM 1635, SRM 1632c, and another standard reference material (SRM 2682b, Sulfur and Mercury in Coal). The developed LA-ICP-IDMS method with its simple sample pretreatment opens the possibility for accurate, fast, and highly sensitive determinations of environmentally critical contaminants in coal as well as of trace impurities in similar sample materials like graphite powder and activated charcoal on a routine basis. (orig.)

  8. Development of an isotope labeling ultra-high performance liquid chromatography mass spectrometric method for quantification of acylglycines in human urine

    Energy Technology Data Exchange (ETDEWEB)

    Stanislaus, Avalyn; Guo, Kevin [Department of Chemistry, University of Alberta, Edmonton, Alberta (Canada); Li Liang, E-mail: Liang.Li@ualberta.ca [Department of Chemistry, University of Alberta, Edmonton, Alberta (Canada)

    2012-10-31

    Graphical abstract: - Abstract: Acylglycines play a crucial regulatory and detoxification role in the accumulation of the corresponding acyl CoA esters and are an important class of metabolites in the diagnoses of inborn errors of metabolism. Sensitive quantification of a large number of acylglycines not only improves diagnosis but also enables the discovery of potential new biomarkers of diseases. We report an ultra-high performance liquid chromatography tandem mass spectrometry (UPLC-MS) method for quantifying acylglycines in human urine with high sensitivity. This method is based on the use of a newly developed isotope labeling reagent, p-dimethylaminophenacyl (DmPA) bromide, to label acylglycines to improve detection sensitivity. Eighteen acylglycines, namely acetylglycine, propionylglycine, isobutyrylglycine, butyrylglycine, 4-hydroxyphenylacetylglycine, 2-furoylglycine, tiglylglycine, 2-methybutyrylglycine, 3-methylcrotonylglycine, isovalerylglycine, valerylglycine, hexanoylglycine, phenylacetylglycine, phenylpropionylglycine, glutarylglycine, heptanoylglycine, octanoylglycine and suberylglycine, were measured. This method uses calibration standards prepared in surrogate matrix (un-derivatized urine) and stable-isotope labeled analytes as the internal standards. The analysis was carried out in the positive ion detection mode using multiple reaction monitoring (MRM) survey scans. The calibration curves were validated over the range of 1.0-500 nM. The method achieved a lower limit of quantitation (LLOQ) of 1-5 nM for all analytes, as measured by the standard derivations associated with calibration curves and confirmed in surrogate matrix; the signal-to-noise ratio at LLOQ ranged from 12.50 to 156.70. Both accuracy (% RE or relative error) and precision (% CV) were <15%. Matrix effects were minimized using the surrogate matrix. All eighteen analytes were stable in urine for at least 5 h at room temperature, autosampler (4 Degree-Sign C) for 24 h, 7 weeks at -20

  9. Development of isotope labeling liquid chromatography mass spectrometry for mouse urine metabolomics: quantitative metabolomic study of transgenic mice related to Alzheimer's disease.

    Science.gov (United States)

    Peng, Jun; Guo, Kevin; Xia, Jianguo; Zhou, Jianjun; Yang, Jing; Westaway, David; Wishart, David S; Li, Liang

    2014-10-03

    Because of a limited volume of urine that can be collected from a mouse, it is very difficult to apply the common strategy of using multiple analytical techniques to analyze the metabolites to increase the metabolome coverage for mouse urine metabolomics. We report an enabling method based on differential isotope labeling liquid chromatography mass spectrometry (LC-MS) for relative quantification of over 950 putative metabolites using 20 μL of urine as the starting material. The workflow involves aliquoting 10 μL of an individual urine sample for ¹²C-dansylation labeling that target amines and phenols. Another 10 μL of aliquot was taken from each sample to generate a pooled sample that was subjected to ¹³C-dansylation labeling. The ¹²C-labeled individual sample was mixed with an equal volume of the ¹³C-labeled pooled sample. The mixture was then analyzed by LC-MS to generate information on metabolite concentration differences among different individual samples. The interday repeatability for the LC-MS runs was assessed, and the median relative standard deviation over 4 days was 5.0%. This workflow was then applied to a metabolomic biomarker discovery study using urine samples obtained from the TgCRND8 mouse model of early onset familial Alzheimer's disease (FAD) throughout the course of their pathological deposition of beta amyloid (Aβ). It was showed that there was a distinct metabolomic separation between the AD prone mice and the wild type (control) group. As early as 15-17 weeks of age (presymptomatic), metabolomic differences were observed between the two groups, and after the age of 25 weeks the metabolomic alterations became more pronounced. The metabolomic changes at different ages corroborated well with the phenotype changes in this transgenic mice model. Several useful candidate biomarkers including methionine, desaminotyrosine, taurine, N1-acetylspermidine, and 5-hydroxyindoleacetic acid were identified. Some of them were found in previous

  10. Statistical model for classifying the feeding systems of Iberian pigs through Gas Chromatography (GC-FID and Isotope Ratio Mass Spectrometry (GC-C-IRMS

    Directory of Open Access Journals (Sweden)

    García-Casco, J. M.

    2013-04-01

    Full Text Available In the present work we have analyzed a total of 734 subcutaneous fat samples from Iberian pigs with different feeding systems for fattening (“Bellota”, “Recebo”, “Campo” and “Cebo” over three consecutive years, 2009-2011. Lipids were extracted from the subcutaneous fat on the rump, and after esterification, they were analyzed by Gas Chromatography (GC-FID and Gas Chromatography- Combustion-Isotope Ratio Mass Spectrometry (GC-C-IRMS. Mean fatty acids and isotope ratios show that there are differences according to the year and feeding systems, two factors that should be taken into account when classifying the animals. The application of different prediction models based on Discriminant analysis has allowed us to establish a method for the classification of animals according to the feeding system type, with a correct percentage of 85% using three or four classification categories (Bellota, Recebo, Campo and/or Cebo and 91% using only two categories, Cebo and Bellota. This model could provide the basis for appropriate classification of Iberian pigs according to their feeding regime.En el presente trabajo se han analizado un total de 734 muestras de tejido subcutáneo de cerdos ibéricos con distintos tipos de alimentación de engorde (Bellota, Recebo, Cebo y Campo a lo largo de tres años consecutivos, 2009-2011. Se han extraído los lípidos de la grasa subcutánea de rabadilla, y después de su esterificación, se han analizado por Cromatografía de gases (GC-FID y por Espectrometría de masas de relaciones isotópicas (GC-C-IRMS. Las medias de los ácidos grasos y de las relaciones isotópicas muestran que existen diferencias según el año y tipo de alimentación, factores que deberían tenerse en cuenta a la hora de clasificar los animales. La aplicación de distintos modelos de predicción basados en análisis discriminante permite establecer un método para la clasificación de los animales según el tipo de alimentación, con

  11. Benzylic rearrangement stable isotope labeling for quantitation of guanidino and ureido compounds in thyroid tissues by liquid chromatography-electrospray ionization mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Ruo-Jing [State Key Laboratory of Organmetallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032 (China); Guan, Qing [Department of Head and Neck Surgery, Fudan University Shanghai Cancer Center, Shanghai, 200032 (China); Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, 200032 (China); Zhang, Fang, E-mail: fzhang@sioc.ac.cn [State Key Laboratory of Organmetallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032 (China); Leng, Jia-Peng [State Key Laboratory of Organmetallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032 (China); Sun, Tuan-Qi, E-mail: tuanqisun@163.com [Department of Head and Neck Surgery, Fudan University Shanghai Cancer Center, Shanghai, 200032 (China); Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, 200032 (China); Guo, Yin-Long, E-mail: ylguo@sioc.ac.cn [State Key Laboratory of Organmetallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032 (China)

    2016-02-18

    Benzylic rearrangement stable isotope labeling (BRSIL) was explored to quantify the guanidino and ureido compounds (GCs and UCs). This method employed a common reagent, benzil, to label the guanidino and ureido groups through nucleophilic attacking then benzylic migrating. The use of BRSIL was investigated in the analysis of five GCs (creatine, L-arginine, homoarginine, 4-guanidinobutyric acid, and methylguanidine) and two UCs (urea and citrulline). The labeling was found simple and specific. The introduction of bi-phenyl group and the generation of nitrogen heterocyclic ring in the benzil-d0/d5 labeled GCs and UCs improved the retention behaviors in liquid chromatography (LC) and increased the sensitivity of electrospray ionization mass spectrometry (ESI MS) detection. The fragment ion pairs of m/z 182/187 and m/z 210/215 from the benzil-d0/d5 tags facilitated the discovery of potential GCs and UCs candidates residing in biological matrices. The use of BRSIL combined with LC-ESI MS was applied for simultaneously quantitation of GCs and UCs in thyroid tissues. It was demonstrated that nine GCs and UCs were detected, six of which were further quantified based on corresponding standards. It was concluded that five GCs and UCs (L-arginine, homoarginine, 4-guanidinobutyric acid, methylguanidine, and citrulline) were statistically significantly different (p < 0.05) between the para-carcinoma and carcinoma thyroid tissue samples. - Highlights: • A common reagent, benzil-d0/d5 was employed to label the GCs and UCs through BRSIL. • The benzil-d0/d5 labeling improved the retention behavior in RPLC and increased the sensitivity by ESI MS detection. • BRSIL coupled with LC-ESI MS was applied to the qualitation and quantitation of GCs and UCs in thyroid tissues.

  12. On-line gas chromatography combustion/pyrolysis isotope ratio mass spectrometry (HRGC-C/P-IRMS) of pineapple (Ananas comosus L. Merr.) volatiles.

    Science.gov (United States)

    Preston, Christina; Richling, Elke; Elss, Sandra; Appel, Markus; Heckel, Frank; Hartlieb, Ariane; Schreier, Peter

    2003-12-31

    By use of extracts prepared by liquid-liquid separation of the volatiles from self-prepared juices of pineapple fruits (Ananas comosus) (n = 14) as well as commercial pineapple recovery aromas/water phases (n = 3), on-line capillary gas chromatography-isotope ratio mass spectrometry was employed in the combustion (C) and the pyrolysis (P) modes (HRGC-C/P-IRMS) to determine the delta(13)C(VPDB) and delta(2)H(VSMOW) values of selected pineapple flavor constituents. In addition to methyl 2-methylbutanoate 1, ethyl 2-methylbutanoate 2, methyl hexanoate 3, ethyl hexanoate 4, and 2,5-dimethyl-4-methoxy-3[2H]-furanone 5, each originating from the fruit, the delta(13)C(VPDB) and delta(2)H(VSMOW) data of commercial synthetic 1-5 and "natural" (biotechnologically derived) 1-4 were determined. With delta(13)C(VPDB) data of pineapple volatiles 1-4 varying from -12.8 to -24.4 per thousand, the range expected for CAM metabolism was observed. Compound 5 showed higher depletion from -20.9 to -28.6 per thousand. A similar situation was given for the delta(2)H(VSMOW) values of 3-5 from pineapple ranging from -118 to -191 per thousand, whereas 1 and 2 showed higher depleted values from -184 to -263 per thousand. In nearly all cases, analytical differentiation of 1-5 from pineapple and natural as well as synthetic origin was possible. In general, natural and synthetic 1-5 exhibited delta(13)C(VPDB) data ranging from -11.8 to -32.2 per thousand and -22.7 to -35.9 per thousand, respectively. Their delta(2)H(VSMOW) data were in the range from -242 to -323 per thousand and -49 to -163 per thousand, respectively.

  13. Stable isotopes. Applications and production; Les isotopes stables. Applications - production

    Energy Technology Data Exchange (ETDEWEB)

    Goldstein, S.; Louvet, P.; Soulie, E. [eds.

    1994-12-31

    This conference presents 46 communications concerning stable isotope production, utilization and application, grouped in 6 sessions and posters. The various themes are: biological applications (pharmacology, medical diagnosis, metabolism and protein studies, toxicity and response studies, labelled compounds), analysis procedures (NMR analysis for macromolecules, tracer studies), nuclear applications (utilization of stable isotopes in nuclear reactors), biological, physical and chemical applications (mass transfer, mobility, crystallography, isotopic exchange), stable isotope production (ion chromatography, ion cyclotron resonance, cryogenic distillation).

  14. Authenticity assessment of gamma- and delta-decalactone from prunus fruits by gas chromatography combustion/pyrolysis isotope ratio mass spectrometry (GC-C/P-IRMS).

    Science.gov (United States)

    Tamura, Hirotoshi; Appel, Markus; Richling, Elke; Schreier, Peter

    2005-06-29

    Authenticity assessment of gamma-decalactone (1) and delta-decalactone (2) from peach (Prunus persica var. persica), apricot (Prunus armeniaca), and nectarine (Prunus persica var. nectarina) was performed using gas chromatography-isotope ratio mass spectrometry (GC-IRMS) in the combustion (C) and pyrolysis (P) mode. In addition, commercially available synthetic (nature-identical) 1 and 2 as well as biotechnologically produced samples (declared to be "natural") were characterized by their delta(2)H(V)(-)(SMOW) and delta(13)C(V)(-)(PDB) values. For the Prunus fruits under study, rather narrow ranges of delta(13)C(V)(-)(PDB) and delta(2)H(V)(-)(SMOW) data of 1, varying from - 34.6 per thousand to - 38.4 per thousand and -160 per thousand to -206 per thousand, respectively, were obtained. Synthetic references of 1 showed delta(13)C(V)(-)(PDB) and delta(2)H(V)(-)(SMOW) data ranging from -27.4 per thousand to -28.3 per thousand and -151 per thousand to -184 per thousand, respectively. Samples of 1 declared to be "natural" exhibited ranges from -28.1 per thousand to -29.2 per thousand and -192 per thousand to -286 per thousand for delta(13)C(V)(-)(PDB) and delta(2)H(V)(-)(SMOW), respectively. For 2 from peach, apricot, and nectarine, delta(13)C(V)(-)(PDB) values ranging from -34.0 per thousand to -37.9 per thousand were determined; the delta(2)H(V)(-)(SMOW) values ranged from -171 per thousand to -228 per thousand. The delta(13)C(V)(-)(PDB) and delta(2)H(V)(-)(SMOW) data for synthetic 2 were -28.2 per thousand and -171 per thousand, respectively, that is, similar to those of 2 from "natural" origin, ranging from -27.7 per thousand to -30.1 per thousand and -185 per thousand to -230 per thousand for delta(13)C(V)(-)(PDB) and delta(2)H(V)(-)(SMOW), respectively. GC-C/P-IRMS allowed clear-cut analytical differentiation of the synthetic and "ex-plant" origin of 1 and 2, whereas narrow ranges of delta(13)C(V)(-)(PDB) and delta(2)H(V)(-)(SMOW) data were found for samples of

  15. Quantitation of anacetrapib, stable-isotope labeled-anacetrapib (microdose), and four metabolites in human plasma using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Chavez-Eng, C M; Lutz, R W; Li, H; Goykhman, D; Bateman, K P; Woolf, E

    2016-02-01

    An ultra-high performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS) method for the simultaneous determination of (4S,5R)-5-[3,5-bis (trifluoromethyl)phenyl]-3-{[4'-fluoro-5'-isopropyl-2'-methoxy-4-(trifluoromethyl)biphenyl-2-yl] methyl}-4-methyl-1,3-oxazolidin-2-one (anacetrapib, I) and [(13)C5(15)N]-anacetrapib, II in human plasma has been developed to support a clinical study to determine the absolute bioavailability of I. The analytes and the stable-isotope labeled internal standard ([(13)C7(15)N(2)H7]-anacetrapib, III) were extracted from 100μL of human plasma by liquid-liquid extraction using 20/80 isopropyl alcohol/hexane (v/v). The chromatographic separation of the analytes was achieved using Waters BEH Shield RP 18 (50×2.1mm×1.7μm) column and mobile phase gradient of 0.1% formic acid in water (Solvent A) and 0.1% formic acid in acetonitrile (Solvent B) at 0.6mL/min flow rate. The MS/MS detection was performed on AB Sciex 5000 or AB 5500 in positive electrospray ionization mode, operated in selected reaction monitoring mode. The assay was validated in the concentration range 1-2000ng/mL for I; and a lower curve range, 0.025-50ng/mL for II. In addition to the absolute bioavailability determination, it was desired to better elucidate the pharmacokinetic behavior of several hydroxylated metabolites of I. Toward this end, two exploratory assays for the hydroxy metabolites of I were qualified in the concentration range 0.5-500ng/mL. All metabolites were separated on a Supelco Ascentis Express Phenyl-Hexyl (50×2.1mm, 2.7μm) column. Metabolite M4 was analyzed in the negative mode with a mobile phase consisting of a gradient mixture of water (A) and acetonitrile (B). The other three metabolites, M1-M3 were analyzed in the positive mode using a mobile phase gradient of water with 0.1% formic acid (A) and acetonitrile with 0.1% formic acid (B). The assays were utilized to support a clinical study in which a microdosing approach was used to

  16. Preparation and certification of mussel reference material for organochlorine pesticides and polychlorinated biphenyls using isotope dilution-high resolution mass spectrometry%贻贝中有机氯农药和多氯联苯标准物质的研制及同位素稀释高分辨质谱法定值

    Institute of Scientific and Technical Information of China (English)

    卢宪波; 陈吉平; 王淑秋; 邹黎黎; 田玉增; 倪余文; 苏凡

    2012-01-01

    A method for the preparation and certification of the reference material of organochlorine pesticides ( OCPs) and polychlorinated biphenyls ( PCBs) in mussel tissue is described. The mussel tissue from Dalian Bay was frozen-dried, comminuted, sieved, homogenized , packaged, and sterilized by 60Co radiation sterilization in turn. The certified values for 18 OCPs and 16 PCBs were determined by high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) using isotope dilution and internal standard quantitation techniques. The certified values were validated and given based on seven accredited laboratories, and these values are traceable to the SI (international system of units) through gravimetri-cally prepared standards of established purity and measurement intercomparisons. The certified values of PCBs and OCPs in mussel span 4 orders of magnitude with a relative uncertainty of about 10%. This material is a natural biological material with confirmed good homogeneity and stability, and it was approved as the grade "primary reference material" (GBW10069) in June 2012 in China. This reference material provided necessary quality control products for our country to implement the Stockholm Treaty on the monitoring of persistent organic pollutants (POPs). The material is intended to be used for the method validation and quality control in the determination of OCPs and PCBs in biota samples.%建立了贻贝中有机氯农药(OCPs)和多氯联苯(PCBs)标准物质的研制和定值方法,该研究对我国开展环境生物标准物质的研制具有重要的方法学借鉴价值.该标准物质样品为采自大连湾海域的贻贝,其定值目标物包括18种OCPs和16种PCBs,采用的定值测量方法是目前世界上最权威、最准确的同位素稀释-高分辨气相色谱/高分辨质谱联用法( ID-HRGC/HRMS) 所研制的标准物质具有定值目标物种类多、不确定度较小(约10%)等特点.该标准物质是目前国际上唯

  17. Direct Analysis of Leucine and Its Metabolites β-Hydroxy-β-methylbutyric Acid, α-Ketoisocaproic Acid, and α-Hydroxyisocaproic Acid in Human Breast Milk by Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Ehling, Stefan; Reddy, Todime M

    2015-09-02

    A direct, quantitative, and confirmatory method based on stable isotope dilution liquid chromatography-mass spectrometry was developed and validated for the analysis of leucine and metabolites β-hydroxy-β-methylbutyric acid (HMB), α-ketoisocaproic acid (KIC), and α-hydroxyisocaproic acid (HICA) in human breast milk. Chromatographic resolution was achieved between isobaric leucine and isoleucine. Accuracy and intermediate precision were 89-117% and breast milk composition and its effect on protein turnover in developing infants.

  18. Collaborative trial validation study of two methods, one based on high performance liquid chromatography-tandem mass spectrometry and on gas chromatography-mass spectrometry for the determination of acrylamide in bakery and potato products.

    Science.gov (United States)

    Wenzl, Thomas; Karasek, Lubomir; Rosen, Johan; Hellenaes, Karl-Erik; Crews, Colin; Castle, Laurence; Anklam, Elke

    2006-11-03

    A European inter-laboratory study was conducted to validate two analytical procedures for the determination of acrylamide in bakery ware (crispbreads, biscuits) and potato products (chips), within a concentration range from about 20 microg/kg to about 9000 microgg/kg. The methods are based on gas chromatography-mass spectrometry (GC-MS) of the derivatised analyte and on high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) of native acrylamide. Isotope dilution with isotopically labelled acrylamide was an integral part of both methods. The study was evaluated according to internationally accepted guidelines. The performance of the HPLC-MS/MS method was found to be superior to that of the GC-MS method and to be fit-for-the-purpose.

  19. Multidimensional enantio gas chromtography/mass spectrometry and gas chromatography-combustion-isotopic ratio mass spectrometry for the authenticity assessment of lime essential oils (C. aurantifolia Swingle and C. latifolia Tanaka).

    Science.gov (United States)

    Bonaccorsi, Ivana; Sciarrone, Danilo; Schipilliti, Luisa; Dugo, Paola; Mondello, Luigi; Dugo, Giovanni

    2012-02-24

    This article focuses on the genuineness assessment of Lime oils (Citrus aurantifolia Swingle and C. latifolia Tanaka), by Multi Dimensional Gas Chromatography (MDGC) to determine the enantiomeric distribution of α-thujene, camphene, β-pinene, sabinene, α-phellandrene, β-phellandrene, limonene, linalool, terpinen-4-ol, α-terpineol and by gas chromatography-combustion isotope ratio mass spectrometry (GC-C-IRMS) to determine the isotopic ratios of α-pinene, β-pinene, limonene, α-terpineol, neral, geranial, β-caryophyllene, trans-α-bergamotene, germacrene B. To the author's knowledge this is the first attempt to assess the authenticity and differentiate Persian Lime from Key lime oils by GC-C-IRMS. The results of the two analytical approaches were compared. The simultaneous use of the two techniques provides more reliable capability to detect adulteration in Citrus essential oils. In fact, in some circumstance only one of the two techniques allows to discriminate adulterated or contaminated oils. In cases where only small anomalies are detected by the two techniques due to subtle adulterations, their synergic use allows to express judgments. The advantage of both techniques is the low number of components the analyst must evaluate, reducing the complexity of the data necessary to deal with. Moreover, the conventional analytical approach based on the evaluation of the whole volatile fraction can fail to reveal the quality of the oils, if the adulteration is extremely subtle. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Hybridizing pines with diluted pollen

    Science.gov (United States)

    Robert Z. Callaham

    1967-01-01

    Diluted pollens would have many uses by the tree breeder. Dilutions would be particularly advantageous in making many controlled pollinations with a limited amount of pollen. They also would be useful in artificial mass pollinations of orchards or single trees. Diluted pollens might help overcome troublesome genetic barriers to crossing. Feasibility o,f using diluted...

  1. Full quantification of selenium species by RP and AF-ICP-qMS with on-line isotope dilution in serum samples from mercury-exposed people supplemented with selenium-enriched yeast

    DEFF Research Database (Denmark)

    Li, Yu-Feng; Hu, Liang; Li, Bai

    2011-01-01

    Accurate determination of selenium (Se) species in biological samples is a critical issue because Se commonly occurs at low levels and in diverse species. The method for the full quantification of Se species in serum samples was proposed through combined ion-pair reverse-phase (RP) chromatography...

  2. Simultaneous Detection of Androgen and Estrogen Abuse in Breeding Animals by Gas Chromatography-Mass Spectrometry/Combustion/Isotope Ratio Mass Spectrometry (GC-MS/C/IRMS) Evaluated against Alternative Methods.

    Science.gov (United States)

    Janssens, Geert; Mangelinckx, Sven; Courtheyn, Dirk; De Kimpe, Norbert; Matthijs, Bert; Le Bizec, Bruno

    2015-09-02

    The administration of synthetic homologues of naturally occurring steroids can be demonstrated by measuring (13)C/(12)C isotopic ratios of their urinary metabolites. Gas chromatography-mass spectrometry/combustion/isotope ratio mass spectrometry (GC-MS/C/IRMS) was used in this study to appraise in a global approach isotopic deviations of two 17β-testosterone metabolites (17α-testosterone and etiocholanolone) and one 17β-estradiol metabolite (17α-estradiol) together with those of 5-androstene-3β,17α-diol as endogenous reference compound (ERC). Intermediate precisions of 0.35‰, 1.05‰, 0.35‰, and 0.21‰, respectively, were observed (n = 8). To assess the performance of the analytical method, a bull and a heifer were treated with 17β-testosterone propionate and 17β-estradiol-3-benzoate. The sensitivity of the method permitted the demonstration of 17β-estradiol treatment up to 24 days. For 17β-testosterone treatment, the detection windows were 3 days and 24 days for the bull and the heifer, respectively. The capability of GC-MS/C/IRMS to demonstrate natural steroid abuse for urinary steroids was eventually compared to those of mass spectrometry (LC-MS/MS) when measuring intact steroid esters in blood and hair.

  3. Evaluation of uncertainty for determination of trace thorium in U3O8 by isotope dilution inductively coupled plasma mass spectrometry%ID-ICP-MS测定八氧化三铀中痕量钍的不确定度评定

    Institute of Scientific and Technical Information of China (English)

    初泉丽; 曹淑琴; 张亮

    2011-01-01

    Taking determination of trace thorium in U3O8 by isotope dilution inductively coupled plasma mass spectrometry(ID-ICP-MS) as example, the uncertainty in measurement was evaluated. All parameters needed for the calculation process were collected and calculated, and a mathematical model was set up. The sources of the uncertainty in measurement were determined, and components of the uncertainty in measurement were synthetized with EXCEL software.%对同位素稀释电感耦合等离子体质谱法(ID-ICP-MS)测定八氧化三铀中痕量钍的不确定度进行评定,确定了不确定度来源,并使用EXCEL进行不确定度各分量的定量、合成.

  4. Multi-elemental Gd, Eu, Sm, Nd isotope ratio measurements by liquid chromatography coupled to MC-ICPMS with variable Faraday cup configurations during elution.

    Science.gov (United States)

    Guéguen, Florence; Nonell, Anthony; Isnard, Hélène; Vio, Laurent; Chartier, Frédéric

    2017-01-01

    The high-precision isotopic characterization of actinides and fission products in nuclear samples is fundamental for various applications such as the management of spent nuclear fuel or the validation of neutronic calculation codes. However multi-elemental isotope ratio measurements by mass spectrometric techniques are hampered by the presence of both spectral and non-spectral interferences as complex sample matrices are encountered in such topics, but also due to the lack of high precision mass spectrometers able to cover the entire mass spectrum. This work describes a new LC-MC-ICPMS approach allowing simultaneous high-precision and multi-elemental isotope ratio measurements of four fission products of interest for nuclear issues (Nd, Sm, Eu, Gd) within a single elution run. Variable motorized Faraday cup configurations were successively used during a specifically designed elution procedure in order to take into account the non-natural Nd, Sm, Eu, Gd isotopic compositions encountered in irradiated nuclear samples. This new method, involving the relevant isotopic reference standard injection timings for on-line mass bias corrections, was validated by the analysis of a simulated fission product fraction from a (235)U-irradiated target. Reproducibilities better than 2‰ (k=2), comparable to those obtained by off-line measurements and the classic sample-standard bracketing mass bias correction approach, were obtained for all isotope ratios, except those involving isotopes with a transient signal peak apex lower than 100mV, for which the reproducibilities were comprised between 2‰ and 6‰.

  5. The Re-Os Isotopic System: Geochemistry and Methodology at the Geochronological Research Center (CPGeo of the University of São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Ciro Teixeira Correia

    2007-04-01

    Full Text Available The Re-Os isotopic system is an important tool for the study of mantle-crust processes, geochronology and the tracingof source reservoirs for metal deposition. Rhenium and osmium differ fundamentally from other lithophile isotopic systemswith regards to their behavior during partial melting processes, coupled with the chalcophile/siderophile nature of bothelements. These differences make the system extremely useful for a number of novel applications not traditionally addressedby lithophile isotopic systems. A low-blank technique for the analysis of Re-Os isotopes in geological materials has beenestablished at the Geochronological Research Center (CPGeo of the Geosciences Institute of the University of São Paulo,Brazil, with the aim of furthering knowledge of regional geology, tectonic evolution, petrology and ore deposition in SouthAmerica. The techniques described here use isotope dilution to simultaneously determine the concentration of Os and Re aswell the Os isotopic composition of geologic materials. Sample digestion and sample-isotopic spike equilibration are achievedin sealed borosilicate glass tubes at high temperature. Osmium is separated and purified by carbon tetrachloride solventextraction and micro-distillation techniques. Rhenium is separated and purified by anion exchange chromatography. Accuracyof the concentration and isotopic determinations is monitored by the analysis of a certified reference material (WPR-1 andthe use of the Department of Terrestrial Magnetism (DTM Os isotopic standard. Measured values and precision of thesestandards is within error and comparable to established Re-Os laboratories.

  6. Rapid and simultaneous determination of neptunium and plutonium isotopes in environmental samples by extraction chromatography using sequential injection analysis and ICP-MS

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2010-01-01

    This paper reports an automated analytical method for rapid and simultaneous determination of plutonium isotopes (239Pu and 240Pu) and neptunium (237Np) in environmental samples. An extraction chromatographic column packed with TrisKem TEVA® resin was incorporated in a sequential injection (SI...

  7. Analysis of household ignitable liquids and their post-combustion weathered residues using compound-specific gas chromatography-combustion-isotope ratio mass spectrometry.

    Science.gov (United States)

    Schwartz, Zeland; An, Yan; Konstantynova, Kateryna I; Jackson, Glen P

    2013-12-10

    The continuing rise in home and vehicular arson cases involving the use of ignitable liquids continues to be an area of concern for criminal and civil investigators. In this study, the compound-specific δ(13)C values of various components of four flammable household chemicals were measured using a single quadrupole mass spectrometer and an isotope ratio mass spectrometer as simultaneous detectors for a gas chromatograph. Whereas compound-specific carbon isotope ratios were able to discriminate between different sources of neat (pre-combustion) ignitable liquids, analyses of the post-combustion residues were problematic. Weathering caused by combustion resulted in a significant increase in the (13)C content of specific peaks relative to the neat liquids (i.e. less negative delta values) such that the isotopic comparison of pre- and post-combustion residues resulted in fractionation ranging from 0 to +10‰. Because of the current lack of understanding of isotopic fractionation during combustion, and because of problems encountered with co-elution in the more complex samples, compound-specific IRMS does not appear to be suitable for fire debris analysis. The comparison of non-combusted or non-weathered ignitable liquids is much more reliable, especially for relatively simple mixtures, and is best suited for exclusionary purposes until such time as a comprehensive database of samples is developed. Without a measure of the population variance, one cannot presently predict the false positive identification rate for the comparison of two ignitable liquids; i.e. the probability that two random ignitable liquid samples have indistinguishable isotope ratios.

  8. Application of liquid chromatography-mass spectrometry to measure the concentrations and study the synthesis of short chain fatty acids following stable isotope infusions

    NARCIS (Netherlands)

    Meesters, R.J.W.; Eijk, H.M.H. van; Have, G.A.M. ten; Graaf, A.A. de; Venema, K.; Rossum, B.E.J. van; Deutz, N.E.P.

    2007-01-01

    A new method involving zinc sulphate deproteinization was developed to study short chain fatty acids (SCFA) production in the colon and subsequent occurrence of SCFA in blood. SCFA were baseline separated in a 30 min cycle using ion-exclusion chromatography and detected by mass spectrometry. Concent

  9. Application of liquid chromatography-mass spectrometry to measure the concentrations and study the synthesis of short chain fatty acids following stable isotope infusions

    NARCIS (Netherlands)

    Meesters, R.J.W.; Eijk, H.M.H. van; Have, G.A.M. ten; Graaf, A.A. de; Venema, K.; Rossum, B.E.J. van; Deutz, N.E.P.

    2007-01-01

    A new method involving zinc sulphate deproteinization was developed to study short chain fatty acids (SCFA) production in the colon and subsequent occurrence of SCFA in blood. SCFA were baseline separated in a 30 min cycle using ion-exclusion chromatography and detected by mass spectrometry.

  10. Application of liquid chromatography-mass spectrometry to measure the concentrations and study the synthesis of short chain fatty acids following stable isotope infusions

    NARCIS (Netherlands)

    Meesters, R.J.W.; Eijk, H.M.H. van; Have, G.A.M. ten; Graaf, A.A. de; Venema, K.; Rossum, B.E.J. van; Deutz, N.E.P.

    2007-01-01

    A new method involving zinc sulphate deproteinization was developed to study short chain fatty acids (SCFA) production in the colon and subsequent occurrence of SCFA in blood. SCFA were baseline separated in a 30 min cycle using ion-exclusion chromatography and detected by mass spectrometry. Concent

  11. Deuterium/hydrogen ratio analysis of thymol, carvacrol, gamma-terpinene and p-cymene in thyme, savory and oregano essential oils by gas chromatography-pyrolysis-isotope ratio mass spectrometry.

    Science.gov (United States)

    Nhu-Trang, Tran-Thi; Casabianca, Hervé; Grenier-Loustalot, Marie-Florence

    2006-11-03

    Isotope ratio mass spectrometry online coupled with capillary gas chromatography (GC-Py-IRMS) on column INNOWAX is used in the origin specific analysis and the authenticity control of the phenolic essential oils (EOs). Isotopic data delta(2)H(V-SMOW) of thymol and carvacrol in natural essential oils were evidently more depleted than synthetic products (from -49 to 7 per thousand for thymol and -61 per thousand for carvacrol). delta(2)H(V-SMOW) values of p-cymene, gamma-terpinene and thymol in authentic thyme oils (Thymus vulgaris L. and Thymus zygis L.) were found from -300 to -270 per thousand, from -285 to -248 per thousand and from -259 to -234 per thousand, respectively. delta(2)H(V-SMOW) values of carvacrol and p-cymene in authentic oregano oils (Origanum heracleoticum L., Coridothymus capitatus L. and Origanum compactum L.) varied from -223 to -193 per thousand and from -284 to -259 per thousand, respectively. For authentic Satureja montana subsp. montana essential oils, the mean delta(2)H(V-SMOW) value for aromatic compounds were found to be the following: gamma-terpinene -273 per thousand (SD=4.6 per thousand) and p-cymene -283 per thousand (SD=3.0 per thousand), thymol -245 per thousand (SD=1.8 per thousand) and carvacrol -226 per thousand (SD=1.7 per thousand). In addition, p-cymene was previously found as a precursor of the biosynthesis of thymol and carvacrol in thyme oil, thus, we considered p-cymene as an endogenous reference compound (ERC) for D/H ratio analysis. The isotopic fractionation factors alpha(thymol/p-cymene)=1.05 and alpha(carvacrol/p-cymene)=1.08 were obtained and also used to control the authenticity of the phenolic EOs.

  12. [Determination of L-dopa and dopamine in rat brain microdialysate by ultra high performance liquid chromatography-tandem mass spectrometry using stable isotope-coded derivatization coupled with dispersive liquid-liquid microextraction].

    Science.gov (United States)

    Qi, Weimei; Zhao, Xian-en; Qi, Yong; Sun, Zhiwei; Chen, Guang; You, Jinmao; Suo, Yourui

    2015-09-01

    The sensitive detection method of levodopa (L-DOPA) and dopamine (DA) in rat brain microdialysate of Parkinson's disease (PD) is an essential tool for the clinical study and attenuated synergistic drug screening for L-DOPA from traditional Chinese medicines. Using d0/d3-10-methyl-acridone-2-sulfonyl chloride (d0/d3-MASC) as stable isotope derivatization reagent, a novel ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for L-DOPA and DA by stable isotope- coded derivatization coupled with ultrasonic-assisted dispersive liquid-liquid microextraction (UA-DLLME). d3-MASC (light) and d3-MASC (heavy) were used as derivatization reagents for microdialysate samples and standards, respectively. Mixtures of the two solutions were prepared by UA-DLLME for UHPLC-MS/MS analysis with multiple reaction monitoring (MRM) mode. With d3-MASC heavy derivatives as internal standards for corresponding light derivatives from samples, the stable isotope internal standard quantification for L-DOPA and DA was carried out. The stable derivatives were obtained in aqueous acetonitrile (pH 10.8 sodium carbonate-sodium bicarbonate buffer) at 37 °C for 3.0 min, and then were separated within 2.0 min using gradient elution. Linear range was 0.20-1500.0 nmol/L (R > 0.994). LODs were 0.005 and 0.009 nmol/L for DA and L-DOPA (S/N = 3), respectively. This method was validated, and it showed obvious advantages in comparing with the reported methods in terms of sensitivity, analysis speed and anti-matrix interference. This method has been successfully applied to the study of effect of Shouwu Fang on L-DOPA and DA concentration fluctuations in PD rat brain microdialysate.

  13. Quantitative analysis of N-glycans from human alfa-acid-glycoprotein using stable isotope labeling and zwitterionic hydrophilic interaction capillary liquid chromatography electrospray mass spectrometry as tool for pancreatic disease diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Giménez, Estela, E-mail: estelagimenez@ub.edu [Department of Analytical Chemistry, University of Barcelona, Diagonal 647, E-08028 Barcelona (Spain); Balmaña, Meritxell [Biochemistry and Molecular Biology Unit, Department of Biology, University of Girona, Campus Montilivi s/n, 17071 Girona (Spain); Figueras, Joan [Department of Surgery, Dr. Josep Trueta University Hospital, IdlBGi, 17007 Girona (Spain); Fort, Esther [Digestive Unit, Dr. Josep Trueta University Hospital, 17007 Girona (Spain); Bolós, Carme de [Gastroesophagic Cancer Research Group, Research Programme in Cancer, Hospital del Mar Medical Research Institute (IMIM), Dr. Aiguader, 88, 08003 Barcelona (Spain); Sanz-Nebot, Victòria [Department of Analytical Chemistry, University of Barcelona, Diagonal 647, E-08028 Barcelona (Spain); Peracaula, Rosa [Biochemistry and Molecular Biology Unit, Department of Biology, University of Girona, Campus Montilivi s/n, 17071 Girona (Spain); Rizzi, Andreas [Institute of Analytical Chemistry, University of Vienna, Währinger Straße 38, A-1090 Vienna (Austria)

    2015-03-25

    Highlights: • The method enables relative quantitation of hAGP glycans from pathological samples • Pancreatic cancer samples clearly showed an increase of hAGP fucosylated glycans. • Fucosylated glycans could be potential biomarkers for diagnosing pancreatic cancer. • The established method could be extremely useful to find novel glycoprotein biomarkers - Abstract: In this work we demonstrate the potential of glycan reductive isotope labeling (GRIL) using [{sup 12}C]- and [{sup 13}C]-coded aniline and zwitterionic hydrophilic interaction capillary liquid chromatography electrospray mass spectrometry (μZIC-HILIC-ESI-MS) for relative quantitation of glycosylation variants in selected glycoproteins present in samples from cancer patients. Human α{sub 1}-acid-glycoprotein (hAGP) is an acute phase serum glycoprotein whose glycosylation has been described to be altered in cancer and chronic inflammation. However, it is not clear yet whether some particular glycans in hAGP can be used as biomarker for differentiating between these two pathologies. In this work, hAGP was isolated by immunoaffinity chromatography (IAC) from serum samples of healthy individuals and from those suffering chronic pancreatitis and different stages of pancreatic cancer, respectively. After de-N-glycosylation, relative quantitation of the hAGP glycans was carried out using stable isotope labeling and μZIC-HILIC-ESI-MS analysis. First, protein denaturing conditions prior to PNGase F digestion were optimized to achieve quantitative digestion yields, and the reproducibility of the established methodology was evaluated with standard hAGP. Then, the proposed method was applied to the analysis of the clinical samples (control vs. pathological). Pancreatic cancer samples clearly showed an increase in the abundance of fucosylated glycans as the stage of the disease increases and this was unlike to samples from chronic pancreatitis. The results gained here indicate the mentioned glycan in h

  14. Isotopic variants of light and heavy L-pyroglutamic acid succinimidyl esters as the derivatization reagents for DL-amino acid chiral metabolomics identification by liquid chromatography and electrospray ionization mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mochizuki, Toshiki; Todoroki, Kenichiro; Inoue, Koichi; Min, Jun Zhe; Toyo’oka, Toshimasa, E-mail: toyooka@u-shizuoka-ken.ac.jp

    2014-02-06

    Graphical abstract: -- Highlights: •Isotopic variants of chiral labeling reagents were newly synthesized. •Analysis of DL-amino acids was performed by UPLC–ESI–MS/MS. •Highly efficient enantioseparation and detection of DL-amino acids were performed. •Differential analysis of DL-amino acid was successfully performed in real samples. -- Abstract: L-Pyroglutamic acid succinimidyl ester (L-PGA-OSu) and its isotopic variant (L-PGA[d{sub 5}]-OSu) were newly synthesized and evaluated as the chiral labeling reagents for the enantioseparation of amino acids, in terms of separation efficiency by reversed-phase chromatography and detection sensitivity by ESI-MS/MS. The enantiomers of amino acids were easily labeled with the reagents at 60 °C within 10 min in an alkaline medium containing triethylamine. Although all the diastereomers derived from 18 proteolytic amino acids could not be satisfactorily separated, the pairs of 9 amino acids were completely separated by reversed-phase chromatography using the small particle (1.7 μm) ODS column (Rs = 1.95–8.05). The characteristic daughter ions, i.e., m/z 84.04 and m/z 89.04, were detected from all the derivatives by the collision induced dissociation of the protonated molecular ions. A highly sensitive detection at a low-fmol level (0.5–3.2 fmol) was also obtained from the selected reaction monitoring (SRM) chromatograms. An isotope labeling strategy using light and heavy L-PGA-OSu for the differential analysis of the DL-amino acids in different sample groups is also presented in this paper. The differential analysis of biological sample (i.e., human serum) and food product (i.e., yogurt) were tried to demonstrate the efficiency of the proposed method. The ratios of the DL-amino acids in human serum samples, spiked with the different concentrations of D-amino acids, were determined by the procedures using L-PGA-OSu and L-PGA[d{sub 5}]-OSu. The D/L ratios in the two sample groups at different concentrations of

  15. Development of a Candidate Reference Measurement Procedure for the Determination of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in Human Serum Using Isotope-Dilution Liquid Chromatography/Tandem Mass Spectrometry

    OpenAIRE

    Tai, Susan S.-C.; Bedner, Mary; Karen W. Phinney

    2010-01-01

    Vitamin D exists in two major forms, vitamin D3 and vitamin D2. Vitamin D helps the body absorb calcium and promote optimal bone health. Both forms of vitamin D are metabolized to 25-hydroxyvitamin D in the body, and the levels of 25-hydroxyvitamin D3 [25(OH)D3] and 25-hydroxyvitamin D2 [25(OH)D2] in serum are considered the best indicators of vitamin D status. A candidate reference measurement procedure for serum 25(OH)D3 and 25(OH)D2 has been developed and critically evaluated. The deuterat...

  16. Carotene-rich plant foods ingested with minimal dietary fat enhance the total-body vitamin A pool size in Filipino schoolchildren as assessed by stable-isotope-dilution methodology.

    Science.gov (United States)

    Ribaya-Mercado, Judy D; Maramag, Cherry C; Tengco, Lorena W; Dolnikowski, Gregory G; Blumberg, Jeffrey B; Solon, Florentino S

    2007-04-01

    Strategies for improving the vitamin A status of vulnerable populations are needed. We studied the influence of the amounts of dietary fat on the effectiveness of carotene-rich plant foods in improving vitamin A status. Schoolchildren aged 9-12 y were fed standardized meals 3 times/d, 5 d/wk, for 9 wk. The meals provided 4.2 mg provitamin A carotenoids/d (mainly beta-carotene) from yellow and green leafy vegetables [carrots, pechay (bok choy), squash, and kangkong (swamp cabbage)] and 7, 15, or 29 g fat/d (2.4, 5, or 10 g fat/meal) in groups A, B, and C (n = 39, 39, and 38, respectively). Other self-selected foods eaten were recorded daily. Before and after the intervention, total-body vitamin A pool sizes and liver vitamin A concentrations were measured with the deuterated-retinol-dilution method; serum retinol and carotenoid concentrations were measured by HPLC. Similar increases in mean serum beta-carotene (5-fold), alpha-carotene (19-fold), and beta-cryptoxanthin (2-fold) concentrations; total-body vitamin A pool size (2-fold); and liver vitamin A (2-fold) concentrations were observed after 9 wk in the 3 study groups; mean serum retinol concentrations did not change significantly. The total daily beta-carotene intake from study meals plus self-selected foods was similar between the 3 groups and was 14 times the usual intake; total fat intake was 0.9, 1.4, or 2.0 times the usual intake in groups A, B, and C, respectively. The overall prevalence of low liver vitamin A (<0.07 mumol/g) decreased from 35% to 7%. Carotene-rich yellow and green leafy vegetables, when ingested with minimal fat, enhance serum carotenoids and the total-body vitamin A pool size and can restore low liver vitamin A concentrations to normal concentrations.

  17. Lowering detection limits for 1,2,3-trichloropropane in water using solid phase extraction coupled to purge and trap sample introduction in an isotope dilution GC-MS method.

    Science.gov (United States)

    Liao, Wenta; Ghabour, Miriam; Draper, William M; Chandrasena, Esala

    2016-09-01

    Purge and trap sample introduction (PTI) has been the premier sampling and preconcentration technique for gas chromatographic determination of volatile organic compounds (VOCs) in drinking water for almost 50 years. PTI affords sub parts-per-billion (ppb) detection limits for purgeable VOCs including fixed gases and higher boiling hydrocarbons and halocarbons. In this study the coupling of solid phase extraction (SPE) to PTI was investigated as a means to substantially increase enrichment and lower detection limits for the emerging contaminant, 1,2,3-trichloropropane (TCP). Water samples (500 mL) were dechlorinated, preserved with a biocide, and spiked with the isotope labeled internal standard, d5-TCP. The entire 500 mL sample was extracted with activated carbon or carbon molecular sieve SPE cartridges, and then eluted with dichloromethane -- excess solvent was removed in a nitrogen evaporator and diethylene glycol "keeper" remaining was dispersed in 5 mL of water for PTI GC-MS analysis. The experimental Method Detection Limit (MDL) for TCP was 0.11 ng/L (ppt) and accuracy was 95-103% in sub-ppt determinations. Groundwater samples including impaired California sources and treated water (n = 21) were analyzed with results ranging from below the method reporting limit (0.30 ng/L) to > 250 ng/L. Coupling of SPE with PTI may provide similar reductions in detection limits for other VOCs with appropriate physical-chemical properties.

  18. Enantioselective stable isotope analysis (ESIA) of polar Herbicides

    Science.gov (United States)

    Maier, Michael; Qiu, Shiran; Elsner, Martin

    2013-04-01

    The complexity of aquatic systems makes it challenging to assess the environmental fate of chiral micropolutants. As an example, chiral herbicides are frequently detected in the environment (Buser and Muller, 1998); however, hydrological data is needed to determine their degradability from concentration measurements. Otherwise declining concentrations cannot unequivocally be attributed to degradation, but could also be caused by dilution effects. In contrast, isotope ratios or enantiomeric ratios are elegant alternatives that are independent of dilution and can even deliver insights into reaction mechanisms. To combine the advantages of both approaches we developed an enatioselective stable isotope analysis (ESIA) method to investigate the fate of the chiral herbicides 4-CPP ((RS)-2-(4-chlorophenoxy)-propionic acid), mecoprop (2-(4-Chloro-2-methylphenoxy)-propionic acid) and dichlorprop (2-(2,4-Dichlorophenoxy)-propionic acid). After testing the applicable concentration range of the method, enantioselective isotope fractionation was investigated by microbial degradation using dichlorprop as a model compound. The method uses enantioselective gas-chromatography (GC) to separate enantiomers. Subsequently samples are combusted online to CO2 and carbon isotope ratios are determined for each enantiomer by isotope-ratio-mass-spectrometry (IRMS). Because the analytes contain a polar carboxyl-group, samples were derivatised prior to GC-IRMS analysis with methanolic BF3 solution. Precise carbon isotope analysis (2σ ≤0.5‰) was achieved with a high sensitivity of ≥ 7 ng C that is needed on column for one analysis. Microbial degradation of the model compound dichlorprop was conducted with Delftia acidovorans MC1 and pronounced enantiomer fractionation, but no isotope fractionation was detected. The absence of isotope fractionation can be explained by two scenarios: either the degrading enzyme has no isotopic preference, or another step in the reaction without an isotopic

  19. Applying Chromatography.

    Science.gov (United States)

    Klein, Jessie W.; Patev, Paul

    1998-01-01

    Presents three experiments to introduce students to different kinds of chromatography: (1) paper chromatography; (2) gel filtration chromatography; and (3) reverse-phase liquid chromatography. Written in the form of a laboratory manual, explanations of each of the techniques, materials needed, procedures, and a glossary are included. (PVD)

  20. Rapid detection and characterization of reactive drug metabolites in vitro using several isotope-labeled trapping agents and ultra-performance liquid chromatography/time-of-flight mass spectrometry.

    Science.gov (United States)

    Rousu, Timo; Pelkonen, Olavi; Tolonen, Ari

    2009-03-01

    Reactive metabolites are believed to be one of the main reasons for unexpected drug-induced toxicity issues, by forming covalent adducts with cell proteins or DNA. Due to their high reactivity and short lifespan they are not directly detected by traditional analytical methods, but are most traditionally analyzed by liquid chromatography/tandem mass spectrometry (LC/MS/MS) after chemical trapping with nucleophilic agents such as glutathione. Here, a simple but very efficient assay was built up for screening reactive drug metabolites, utilizing stable isotope labeled glutathione, potassium cyanide and semicarbazide as trapping agents and highly sensitive ultra-performance liquid chromatography/time-of-flight mass spectrometry (UPLC/TOFMS) as an analytical tool. A group of twelve structurally different compounds was used as a test set, and a large number of trapped metabolites were detected for most of them, including many conjugates not reported previously. Glutathione-trapped metabolites were detected for nine of the twelve test compounds, whereas cyanide-trapped metabolites were found for eight and semicarbazide-trapped for three test compounds. The high mass accuracy of TOFMS provided unambiguous identification of change in molecular formula by formation of a reactive metabolite. In addition, use of a mass defect filter was found to be a usable tool when mining the trapped conjugates from the acquired data. The approach was shown to provide superior detection sensitivity in comparison to traditional methods based on neutral loss or precursor ion scanning with a triple quadrupole mass spectrometer, and clearly more efficient detection and characterization of reactive drug metabolites with a simpler test setup. Copyright (c) 2009 John Wiley & Sons, Ltd.

  1. Development of a hydrophilic interaction liquid chromatography coupled with matrix-assisted laser desorption/ionization-mass spectrometric imaging platform for N-glycan relative quantitation using stable-isotope labeled hydrazide reagents.

    Science.gov (United States)

    Chen, Zhengwei; Zhong, Xuefei; Tie, Cai; Chen, Bingming; Zhang, Xinxiang; Li, Lingjun

    2017-07-01

    In this work, the capability of newly developed hydrophilic interaction liquid chromatography (HILIC) coupled with matrix-assisted laser desorption/ionization-mass spectrometric imaging (MALDI-MSI) platform for quantitative analysis of N-glycans has been demonstrated. As a proof-of-principle experiment, heavy and light stable-isotope labeled hydrazide reagents labeled maltodextrin ladder were used to demonstrate the feasibility of the HILIC-MALDI-MSI platform for reliable quantitative analysis of N-glycans. MALDI-MSI analysis by an Orbitrap mass spectrometer enabled high-resolution and high-sensitivity detection of N-glycans eluted from HILIC column, allowing the re-construction of LC chromatograms as well as accurate mass measurements for structural inference. MALDI-MSI analysis of the collected LC traces showed that the chromatographic resolution was preserved. The N-glycans released from human serum was used to demonstrate the utility of this novel platform in quantitative analysis of N-glycans from a complex sample. Benefiting from the minimized ion suppression provided by HILIC separation, comparison between MALDI-MS and the newly developed platform HILIC-MALDI-MSI revealed that HILIC-MALDI-MSI provided higher N-glycan coverage as well as better quantitation accuracy in the quantitative analysis of N-glycans released from human serum. Graphical abstract Reconstructed chromatograms based on HILIC-MALDI-MSI results of heavy and light labeled maltodextrin enabling quantitative glycan analysis.

  2. A comprehensive procedure based on gas chromatography-isotope ratio mass spectrometry following high performance liquid chromatography purification for the analysis of underivatized testosterone and its analogues in human urine

    Energy Technology Data Exchange (ETDEWEB)

    Torre, Xavier de la, E-mail: xavier.delatorre@gmail.com [Laboratorio Antidoping, Federazione Medico Sportiva Italiana, Largo Giulio Onesti 1, 00197 Rome (Italy); Colamonici, Cristiana; Curcio, Davide; Molaioni, Francesco [Laboratorio Antidoping, Federazione Medico Sportiva Italiana, Largo Giulio Onesti 1, 00197 Rome (Italy); Botre, Francesco [Laboratorio Antidoping, Federazione Medico Sportiva Italiana, Largo Giulio Onesti 1, 00197 Rome (Italy); Dipartimento di Management, ' Sapienza' Universita di Roma, Via del Castro Laurenziano 9, 00161 Rome (Italy)

    2012-12-05

    Highlights: Black-Right-Pointing-Pointer Overall approach for urine samples purification by HPLC for subsequent GC/C/IRMS analysis in doping control. Black-Right-Pointing-Pointer Detection of pseudo-endogenous androgenic steroids (i.e. testosterone, androstenedione) misuse in sports. Black-Right-Pointing-Pointer Routine analysis of steroids by GC/C/IRMS in sports drug testing. - Abstract: The confirmation by GC/C/IRMS of the exogenous origin of pseudo-endogenous steroids from human urine samples requires extracts of adequate purity. A strategy based on HPLC sample purification prior to the GC/C/IRMS analysis of human urinary endogenous androgens (i.e. testosterone, androsterone and/or androstenediols), is presented. A method without any additional derivatization step is proposed, allowing to simplify the urine pretreatment procedure, leading to extracts free of interferences permitting precise and accurate IRMS analysis, without the need of correcting the measured delta values for the contribution of the derivatizing agent. The HPLC extracts were adequately combined to both reduce the number of GC/C/IRMS runs and to have appropriate endogenous reference compounds (ERC; i.e. pregnanediol, 11-keto-etiocholanolone) on each GC-IRMS run. The purity of the extracts was assessed by their parallel analysis by gas chromatography coupled to mass spectrometry, with GC conditions identical to those of the GC/C/IRMS assay. The method has been validated according to ISO17025 requirements (within assay precision below 0.3 Per-Mille-Sign {sup 13}C delta units and between assay precision below 0.6 Per-Mille-Sign {sup 13}C delta units for most of the compounds investigated) fulfilling the World Anti-Doping Agency requirements.

  3. Profiling of urinary steroids by gas chromatography-mass spectrometry detection and confirmation of androstenedione administration using isotope ratio mass spectrometry.

    Science.gov (United States)

    Wang, Jingzhu; Wu, Moutian; Liu, Xin; Xu, Youxuan

    2011-12-20

    Androstenedione (4-androstene-3,17-dione) is banned by the World Anti-Doping Agency (WADA) as an endogenous steroid. The official method to confirm androstenedione abuse is isotope ratio mass spectrometry (IRMS). According to the guidance published by WADA, atypical steroid profiles are required to trigger IRMS analysis. However, in some situations, steroid profile parameters are not effective enough to suspect the misuse of endogenous steroids. The aim of this study was to investigate the atypical steroid profile induced by androstenedione administration and the detection of androstenedione doping using IRMS. Ingestion of androstenedione resulted in changes in urinary steroid profile, including increased concentrations of androsterone (An), etiocholanolone (Etio), 5α-androstane-3α,17β-diol (5α-diol), and 5β-androstane-3α,17β-diol (5β-diol) in all of the subjects. Nevertheless, the testosterone/epitestosterone (T/E) ratio was elevated only in some of the subjects. The rapid increases in the concentrations of An and Etio, as well as in T/E ratio for some subjects could provide indicators for initiating IRMS analysis only for a short time period, 2-22h post-administration. However, IRMS could provide positive determinations for up to 55h post-administration. This study demonstrated that, 5β-diol concentration or Etio/An ratio could be utilized as useful indicators for initiating IRMS analysis during 2-36h post-administration. Lastly, Etio, with slower clearance, could be more effectively used than An for the confirmation of androstenedione doping using IRMS.

  4. Stable isotope utilization methodology; Methodologie de l`emploi des isotopes stables

    Energy Technology Data Exchange (ETDEWEB)

    Roth, E. [Conservatoire National des Arts et Metiers (CNAM), 75 - Paris (France)

    1994-12-31

    The various applications of stable isotope utilization are reviewed, as a function of their specific properties: poly-isotopic abundance modification is used for tracer applications; the accurate measurement of the stable isotope abundance may be applied to isotopic dilution for ultra-trace measurement, physical constant determination, fluid volume and concentration measurement; isotopic effects, such as reaction equilibrium differences are used for separation and identification of molecule active centers (pharmacology, paleoclimatology, hydrogeological studies) while reaction rate differences (competitive and non competitive methods) are used for the study of reaction mechanisms, such as enzymatic reactions. Analysis techniques (mass spectrometry, nuclear magnetic resonance, optical methods) are reviewed. 2 figs., 18 refs.

  5. Determination of Trace Technetium-99 in Soil Samples by Isotope Dilution/Negative Thermal Ionization Mass Spectrometry%同位素稀释-负热表面电离质谱法分析土壤样品中的超微量99Tc

    Institute of Scientific and Technical Information of China (English)

    汤磊; 王丽雄; 刘雪梅; 龙开明; 杨通在; 熊宗华; 龚建

    2012-01-01

    As an important long-lived and high-abundance fission product, "Tc dispersed into the environment because of the nuclear test in atmosphere, the nuclear fuel cycle and nuclear medicine. The isotope dilution mass spectrometry (IDMS) technology of measuring 99 Tc using 97Tc as the spike was developed. The chemical separation procedure of Tc is established, and the recovery rate is more than 71% for the overall process. 97Tc (97Tc, 84.77%; 98Tc, 15.03%; "Tc, 0.20%) was prepared by irradiation of natural ruthenium metal, then was calibrated by IDMS with "Tc standard material as the spike. The conventional positive thermal ionization mass spectrometry (TIMS) was inapplicable due to the high ionization potential of 7. 3 eV for technetium, therefore based on MgCl2+Ba(OH)2 as the loading reagent, the negative thermal ionization mass spectrometry of technetium was established, and the ion current indensity of 99TcO-4 (M/z= 163) reached 1. 7 × 10-12 A. Then, 99Tc in the soil samples was quantitatively determined by negative thermal ionization mass spectrometry and isotope dilution method. The combined standard uncertainty is better than 3%.%为了定量测定土壤样品中的超微量99Tc,发展了Tc的放化分离纯化流程和负热电离质谱分析技术,自行制备了97Tc稀释剂.建立了土壤样品中超微量Tc的放化分离流程,全流程Tc化学回收率为71%.采用天然Ru粉在高通量反应堆中辐照,提取并标定了97Tc稀释剂(同位素丰度:97Tc,84.77%;98Tc,15.03%;97Tc,0.20%).由于Tc具有极高的电离电位(7.3 eV),采用热表面电离质谱(TIMS)难以测量,因此研究了Tc的负热电离质谱分析技术(NTIMS).对比研究了4种发射剂,使用MgCl2+Ba(OH)2负离子发射剂,Tc标准样品的99TcO-4 (M/z=163)离子流强度可以达到1.7×10-12 A.采用该定量分析技术对土壤样品进行了99Tc的定量测定,合成标准不确定度好于3%.

  6. Measurement of Orotic Acid in Urine by Supercritical Fluid Chromatography

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    This work presents a simple, rapid and reliable supercritical fluid chromatography (SFC) method for a sensitive measurement of orotic acid in human urine. The samples were diluted with deionized water and analyzed directly without any pretreatment.

  7. [Formation of oxalate in oxaliplatin injection diluted with infusion solutions].

    Science.gov (United States)

    Eto, Seiji; Yamamoto, Kie; Shimazu, Kounosuke; Sugiura, Toshimune; Baba, Kaori; Sato, Ayaka; Goromaru, Takeshi; Hagiwara, Yoshiaki; Hara, Keiko; Shinohara, Yoshitake; Takahashi, Kojiro

    2014-01-01

    Oxaliplatin use can cause acute peripheral neuropathy characterized by sensory paresthesias, which are markedly exacerbated by exposure to cold temperatures, and is a dose-limiting factor in the treatment of colorectal cancer.Oxalate is eliminated in a series of nonenzymatic conversions of oxaliplatin in infusion solutions or biological fluids.Elimination of oxalate from oxaliplatin has been suggested as one of the reasons for the development of acute neuropathy.In this study, we developed a high-performance liquid chromatography(HPLC)-based method to detect oxalate formation, and investigated the time dependent formation of oxalate in oxaliplatin diluted with infusion solutions.The results obtained showed that the amount of oxalate in the solution corresponded to 1.6% of oxaliplatin 8 h after oxaliplatin dilution with a 5% glucose solution. On the other hand, oxalate formation from oxaliplatin diluted with a saline solution was ten-fold higher than that from oxaliplatin diluted with the 5% glucose solution.Most patients who were intravenously injected with oxaliplatin experienced venous pain.As a preventive measure against venous pain, dexamethasone was added to the oxaliplatin injection.We measured the amount of oxalate formed in the dexamethasone-containing oxaliplatin injection diluted with a 5% glucose solution.The amount of oxalate formed when dexamethasone was added did not differ significantly from that formed when dexamethasone was not added.Thus, there are no clinical problems associated with the stability of oxaliplatin solutions.

  8. Neuere Chromatographie

    Science.gov (United States)

    Hostettmann, K.

    1983-04-01

    Besides high-performance liquid chromatography (HPLC) which is now a well-established and currently used technique, several emerging methods for the isolation and separation of natural products are receiving considerable attention. Centrifugal thin-layer chromatography is a very rapid technique, but limited in resolution. Of special interest are the recently developed support-free liquid-liquid chromatography methods such as droplet counter-current chromatography (DCCC) and rotation locular counter-current chromatography (RLCC). This latter method was applied to the separation of the enantiomers of (±)-norephedrine.

  9. Determination of metformin and other biguanides in forensic whole blood samples by hydrophilic interaction liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Sørensen, Lambert K

    2012-01-01

    Metformin is an anti-diabetic drug in the biguanide class which also includes phenformin and buformin. Because of the potential adverse effects of the biguanides, a reliable liquid chromatography-tandem mass spectrometry method using pneumatically assisted electrospray ionization was developed for the quantification of the drugs in both live and post-mortem human whole blood. The blood proteins were precipitated by the addition of a mixture of methanol and acetonitrile, and the extract was cleaned up by cation-exchange solid-phase extraction to eliminate ion suppression effects. The separation was performed by hydrophilic interaction liquid chromatography. Matrix-matched calibrants combined with isotope dilution of metformin were used for calibration. The detection limits were 0.01 mg/L for metformin and phenformin and the relative intra-laboratory reproducibility standard deviations were less than 6% at concentrations of 1-10 mg/L. The mean true recoveries were greater than 86%.

  10. Carbon and Nitrogen Isotope Analysis of Atrazine and Desethylatrazine at Sub-μg/L Concentrations in Groundwater

    Science.gov (United States)

    Schreglmann, Kathrin; Hoeche, Martina; Steinbeiss, Sibylle; Reinnicke, Sandra; Elsner, Martin

    2013-04-01

    Environmental degradation of organic micropollutants is difficult to monitor due to their diffuse and ubiquitous input. Current approaches - concentrations measurements over time, or daughter-to-parent compound ratios - may fall short, because they do not consider dilution, compound- specific sorption characteristics or alternative degradation pathways. Compound specific isotope analysis (CSIA) offers an alternative approach based on evidence from isotope values. Until now, however, the relatively high limits for precise isotope analysis by gas chromatography - isotope ratio mass spectrometry (GC-IRMS) have impeded CSIA of sub µg/L scale micropollutant concentrations in field samples. We present the first measurements of C and N isotope ratios of the herbicide atrazine and its metabolite desethylatrazine at concentrations of 100 to 1000 ng/L in natural groundwater samples. Solid phase extraction and preparative HPLC were tested and validated for preconcentration and cleanup of groundwater samples of up to 10 liters without bias by isotope effects. Matrix interferences after solid phase extraction could be greatly reduced by a preparative HPLC cleanup step prior to GC-IRMS analysis. Sensitivity was increased by a factor of 6 to 8 by changing the injection method from large-volume-injection to cold-on-column injection on the GC-IRMS system. Carbon and nitrogen isotope values of field samples showed no obvious correlation with concentrations or desethylatrazine-to-atrazine ratios. Contrary to expectations, however, δ13C values of desethylatrazine were consistently less negative than those of atrazine from the same sites. Potentially, this line of evidence may contain information about further desethylatrazine degradation. In such a case the common practice of using desethylatrazine-to-atrazine ratios would underestimate natural atrazine degradation.

  11. Cationic and neutral nitrosamide: Viable molecules in the dilute gas phase

    DEFF Research Database (Denmark)

    Egsgaard, H.; Carlsen, L.; Weiske, T.;

    1992-01-01

    Nitrosamide, NH2NO, has been generated and characterized in the dilute gas phase by means of neutralization reionization mass spectrometry in combination with extensive isotopic labelling. The molecule was found to be stable under these conditions having a minimal lifetime in the microsecond time...

  12. Distribution coefficients of 60 elements on TODGA resin: application to Ca, Lu, Hf, U and Th isotope geochemistry.

    Science.gov (United States)

    Pourmand, Ali; Dauphas, Nicolas

    2010-05-15

    Batch equilibration experiments are conducted to measure the distribution coefficients (K(d)) of a large number of elements in nitric, nitric plus hydrofluoric, and hydrochloric acids on Eichrom TODGA extraction chromatography resin. The K(d)s are used to devise a multi-element extraction scheme for high-precision elemental and isotopic analyses of Ca, Hf, Lu, Th and U in geological materials, using high-purity lithium metaborate (LiBO(2)) flux fusion that allows rapid digestion of even the most refractory materials. The fusion melt, dissolved in nitric acid, is directly loaded to a TODGA cartridge on a vacuum chamber for elemental separation. An Ln-Spec cartridge is used in tandem with TODGA for Lu purification. The entire procedure, from flux digestion to preparation for isotopic analysis, can be completed in a day. The accuracy of the proposed technique is tested by measuring the concentrations of Ca (standard bracketing), Hf, Lu, Th and U (isotope dilution), and the isotopic composition of Hf in geostandards (USNM3529, BCR-2, BHVO-1, AGV-1 and AGV-2). All measurements are in excellent agreement with recommended literature values, demonstrating the effectiveness of the proposed analytical procedure and the versatility of TODGA resin.

  13. Deuterium dilution technique for body composition assessment: resolving methodological issues in children with moderate acute malnutrition.

    Science.gov (United States)

    Fabiansen, Christian; Yaméogo, Charles W; Devi, Sarita; Friis, Henrik; Kurpad, Anura; Wells, Jonathan C

    2017-08-01

    Childhood malnutrition is highly prevalent and associated with high mortality risk. In observational and interventional studies among malnourished children, body composition is increasingly recognised as a key outcome. The deuterium dilution technique has generated high-quality data on body composition in studies of infants and young children in several settings, but its feasibility and accuracy in children suffering from moderate acute malnutrition requires further study. Prior to a large nutritional intervention trial among children with moderate acute malnutrition, we conducted pilot work to develop and adapt the deuterium dilution technique. We refined procedures for administration of isotope doses and collection of saliva. Furthermore, we established that equilibration time in local context is 3 h. These findings and the resulting standard operating procedures are important to improve data quality when using the deuterium dilution technique in malnutrition studies in field conditions, and may encourage a wider use of isotope techniques.

  14. Systematic comparison of δ13C measurements of testosterone and derivative steroids in a freeze-dried urine candidate reference material for sports drug testing by gas chromatography/combustion/isotope ratio mass spectrometry and uncertainty evaluation using four different metrological approaches.

    Science.gov (United States)

    Munton, Ellaine; Murby, John; Hibbert, D Brynn; Santamaria-Fernandez, Rebeca

    2011-06-15

    An alternative calibration procedure for use when performing carbon isotope ratio measurements by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) has been developed. This calibration procedure does not rely on the corrections in-built in the instrument software, as the carbon isotope ratios of a sample are calculated from the measured raw peak areas. The method was developed for the certification of a urine reference material for sports drug testing, as the estimation of measurement uncertainty is greatly simplified. To ensure that the method is free from bias arising from the choice of calibration material and instrument, the carbon isotope ratios of steroids in urine extracts were measured using two different instruments in different laboratories, and three different reference materials (CU/USADA steroid standards from Brenna Laboratory, Cornell University; NIST RM8539 mineral oil; methane calibrated against NIST RM8560 natural gas). The measurements were performed at LGC and the Australian National Measurement Institute (NMI). It was found that there was no significant difference in measurement results when different instruments and reference materials were used to measure the carbon isotope ratio of the major testosterone metabolites androsterone and etiocholanolone, or the endogenous reference compounds pregnanediol, 11- ketoetiocholanolone and 11β-hydroxyandrosterone. Expanded measurement uncertainties at the 95% coverage probability ranged from 0.21‰ to 1.4‰, depending on analyte, instrument and reference material. The measurement results of this comparison were used to estimate a measurement uncertainty of δ(13)C for the certification of the urine reference material being performed on a single instrument using a single reference material at NMI.

  15. Boiling heat transfer in dilute emulsions

    CERN Document Server

    Roesle, Matthew Lind

    2013-01-01

    Boiling Heat Transfer in Dilute Emulsions synthesizes recent advances and established understanding on the subject of boiling in dilute emulsions. Experimental results from various sources are collected and analyzed, including contemporary experiments that correlate visualization with heat transfer data. Published models of boiling heat transfer in dilute emulsions, and their implementation, are described and assessed against experimental data.

  16. Determination of Toxaphenes in Soil by High-Resolution Double-Focusing Magnetic MS Combined with Isotope Dilution and GC%同位素稀释-气相色谱-高分辨双聚焦磁质谱法测定土壤中毒杀芬的含量

    Institute of Scientific and Technical Information of China (English)

    王荟; 高占; 章勇; 胡冠九

    2016-01-01

    提出了同位素稀释-气相色谱-高分辨质谱法测定土壤样品中3种指示性毒杀芬Parlar26(P26)、Parlar50(P50)和 Parlar62(P62)。以二氯甲烷-丙酮(1+1)混合液为提取溶剂对土壤样品进行微波萃取,提取液经活化硅胶柱净化分离,洗脱液经氮气吹扫浓缩至100μL 后,以13 C12-PCB153为同位素内标,在 DB-5MS 色谱柱上分离,质谱中采用电子轰击离子源。P26、P50和P62的检出限(3.143S)分别为1,3,5 pg,测定值的相对标准偏差(n=5)小于6%。方法用于某地区表层土壤中3种指示性毒杀芬的检测,测得 P26,P50,P62的含量分别为0.08,0.04,0.03 ng· g-1。%A novel method for the determination of 3 indicative toxaphenes comprised of Parlar26 (P26), Parlar50 (P50)and Parlar62 (P62)in soil was proposed,based on high-resolution double-focusing magnetic MS combined with isotope dilution and GC.The sample was treated by microwave assisted extraction with a mixture (1+1)of dichloromethane and acetone as solvent.The extract was then purified on an activated silica gel column. The eluate was concentrated to 100 μL by N2-blowing,13 C12-PCB153 was added as internal standard,and the solution was separated on a DB-5MS column.EI was adopted in MS.The detection limits (3.143S)of P26,P50 and P62 were 1,3,5 pg,respectively.RSDs (n=5)were all less than 6%.The method was used to determine P26,P50 and P62 in a top soil sample,giving results of 0.08,0.04 ,0.03 ng·g-1 ,respectively.

  17. Determining PCDDs/PCDFs in Combustion-residue of An Open-burning Municipal Waste Site and Its Peripheral Soil with Isotope Dilution HRGC/HRMS Technique%用HRGC/HRMS测定开放式生活垃圾焚烧残余物及周边土壤中的PCDDs/PCDFs

    Institute of Scientific and Technical Information of China (English)

    张素坤; 李晓明; 彭平安; 任曼; 麦碧娴; 盛国英; 傅家谟

    2009-01-01

    以广东省东南沿海某开放式生活垃圾焚烧场为研究对象,用高分辨气相色谱/高分辨质谱同位素稀释法测定了垃圾焚烧场底灰、焚烧残余物及周边土壤中的多氯代二苯并对二嗯英和多氯代二苯并呋喃(PCDDs/PCDFs).结果表明,PCDDs/PCDFs的总浓度为161~4 670 ng·kg~(-1),毒性当量为1.10~45.8 ngWHO_(1998)-TEQ·kg~(-1),其中采自垃圾焚烧场的3个样品浓度为30~45 ngWHO_(1998)-TEQ·kg~(-1),剩余的土壤样品中有3个样品其浓度为4~35 ng WHO_(1998)-TEQ·kg~(-1),其余的2个样品浓度<4 ng WHO_(1998)-TEQ·kg~(-1).对比加拿大的土壤指导性标准,75%的测定样品浓度高于该标准,即土壤背景浓度,有25%的样品低于此背景浓度.将垃圾焚烧场焚烧残余物作为土壤改良剂造成受施土壤的PCDDs/PCDFs污染严重,需引起有关部门的高度重视.%An open-burning municipal waste site located in the southeast coast of Guangdong Province was taken as the subject for this study, and the technique of isotope dilution featuring high resolution gas chromatogram/high resolution mass spectrogram(HRGC/HRMS) was used to determine the concentrations of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans(PCDDs/PCDFs) in the bottom ash and combustion-residue of the waste incineration site and in the peripheral soil. As shown by the analytical results, the total concentration of PCDDs/PCDFs was 161~4670 ng·kg~(-1), which corresponded to a toxic equivalent of 1.10~45.8 ngWHO_(1998)-TEQ·kg~(-1). The concentration for three samples collected from the waste incineration site ranged between 30~45 ngWHO_(1998)-TEQ·kg~(-1). In regard to the peripheral soil samples, three samples concentrations 4~35 ng WHO_(1998)-TEQ·kg~(-1), while the remaining two samples concentrations were lower than 4 ng WHO_(1998)-TEQ·kg~(-1). Based on the Canadian guideline for soil quality, 75% of the samples tested in our study concentrations were greater than the

  18. 分散固相萃取-同位素稀释高分辨质谱法测定植物油中16种邻苯二甲酸酯%Determination of 16 phthalate esters in vegetable oils by dispersive solid phase extraction-high resolution mass spectrometry with isotope dilution technique

    Institute of Scientific and Technical Information of China (English)

    陈达炜; 赵晓雪; 赵云峰; 苗虹

    2014-01-01

    目的:采用高效液相色谱-四级杆/静电场轨道阱高分辨质谱建立分散固相萃取法(dispersive solid phase extraction, d-SPE)快速分析植物油中16种邻苯二甲酸酯(Phthalate esters, PAEs)的检测方法。方法样品采用正己烷饱和的乙腈提取,经N-丙基乙二胺(primary secondary amine, PSA)和Nano Carb填料分散固相萃取净化,以BEH phenyl色谱柱为分析柱,0.1%甲酸乙腈及0.1%甲酸水溶液作为流动相进行梯度洗脱分离。采用正离子采集模式对植物油样品进行快速筛查,并对16种PAEs进行定量测定。结果16种PAEs在2~500μg/L范围内呈良好的线性关系,回归系数(r)大于0.995,该方法的定量限为8~10μg/kg。在不同加标水平下的平均回收率为77.9%~115.6%,相对标准偏差为0.3%~8.9%。结论本方法简单、灵敏、准确,适用于植物油中PAEs的快速筛查和定量测定。%Objective To establish a dispersive solid phase extraction (d-SPE)/high-resolution benchtop Q exactive mass spectrometry (HRMS) method for the rapid analysis of 16 phthalate esters (PAEs). Methods The samples were extracted with acetonitrile saturated with hexane, and cleaned up by d-SPE with the N-propyl ethlene diamine (PSA) and Nano Carb as the sorbents. The chromatographic analysis was performed on a BEH phenyl column with 0.1%formic acid in acetonitrile and 0.1%formic acid solution as the mobile phase and a gradient elution program was used. The PAEs were analyzed in positive mode by Q exactive high-resolution mass spectrometry, which were applied in rapid analysis of PAEs for vegetable oils. 16 PAEs analytes were screened qualitatively in the vegetable oil samples and then quantified by isotope dilution technique. Results All the target 16 PAEs showed a good linearity in the range of 2~500μg/L , and the aver-age recovery rates of the spiked vegetable oil samples were in the range of 77.9%~115.6%with the RSD in the range of 0.3%-8.9%. The limit of quantification (LOQ

  19. Turbulence in dilute polymer solutions

    Science.gov (United States)

    Liberzon, A.; Guala, M.; Lüthi, B.; Kinzelbach, W.; Tsinober, A.

    2005-03-01

    The work reported below is a comparative study of the properties of turbulence with weak mean flow in a Newtonian fluid and in a dilute polymer solution with an emphasis on the small scale phenomena. The main tool used is a three-dimensional particle tracking system allowing to measure and follow in a Lagrangian manner the field of velocities, as well as velocity derivatives, and thus vorticity, strain, and a variety of related and dynamically significant quantities. The comparison of data from the two flows allows to directly observe the influence of polymers on these quantities as well as the evolution of material elements in the presence of polymers.

  20. Synthesis of the isotope-labeled derivatization reagent for carboxylic acids, 7-(N,N-dimethylaminosulfonyl)-4-(aminoethyl)piperazino-2,1,3-benzoxadiazole (d6) [DBD-PZ-NH2 (D)], and its application to the quantification and the determination of relative amount of fatty acids in rat plasma samples by high-performance liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Tsukamoto, Yuhki; Santa, Tomofumi; Yoshida, Hiroo; Miyano, Hiroshi; Fukushima, Takeshi; Hirayama, Kazuo; Imai, Kazuhiro; Funatsu, Takashi

    2006-04-01

    The isotope-labeled benzofurazan derivatization reagent for carboxylic acids, 7-(N,N-dimethylaminosulfonyl)-4-(aminoethyl)piperazino-2,1,3-benzoxadiazole (d6) [DBD-PZ-NH2 (D)] was synthesized. DBD-PZ-NH2 (D) was used for the accurate quantification of fatty acids by liquid chromatography/mass spectrometry (LC/MS). The standard fatty acids were derivatized with DBD-PZ-NH2 (D) to the stable isotope-labeled compounds for the fatty acids derivatives of DBD-PZ-NH2 and used for the internal standards. The obtained calibration curves for fatty acids were linear over the range 0.1-200 microM (r2 > 0.999). Fatty acids in plasma samples were determined after derivatization with DBD-PZ-NH2 and analyzed by LC/MS using standard fatty acid DBD-PZ-NH2 (D) derivatives as internal standards. Furthermore, the relative amounts of fatty acids in two plasma samples were determined after derivatization with DBD-PZ-NH2 and DBD-PZ-NH2) (D). The isotope-labeled derivatization reagent was useful for accurate quantification and the determination of relative amounts of the metabolites in biological samples having the target functional group.

  1. Total body skeletal muscle mass: estimation by creatine (methyl-d3) dilution in humans.

    Science.gov (United States)

    Clark, Richard V; Walker, Ann C; O'Connor-Semmes, Robin L; Leonard, Michael S; Miller, Ram R; Stimpson, Stephen A; Turner, Scott M; Ravussin, Eric; Cefalu, William T; Hellerstein, Marc K; Evans, William J

    2014-06-15

    Current methods for clinical estimation of total body skeletal muscle mass have significant limitations. We tested the hypothesis that creatine (methyl-d3) dilution (D3-creatine) measured by enrichment of urine D3-creatinine reveals total body creatine pool size, providing an accurate estimate of total body skeletal muscle mass. Healthy subjects with different muscle masses [n = 35: 20 men (19-30 yr, 70-84 yr), 15 postmenopausal women (51-62 yr, 70-84 yr)] were housed for 5 days. Optimal tracer dose was explored with single oral doses of 30, 60, or 100 mg D3-creatine given on day 1. Serial plasma samples were collected for D3-creatine pharmacokinetics. All urine was collected through day 5. Creatine and creatinine (deuterated and unlabeled) were measured by liquid chromatography mass spectrometry. Total body creatine pool size and muscle mass were calculated from D3-creatinine enrichment in urine. Muscle mass was also measured by magnetic resonance imaging (MRI), dual-energy x-ray absorptiometry (DXA), and traditional 24-h urine creatinine. D3-creatine was rapidly absorbed and cleared with variable urinary excretion. Isotopic steady-state of D3-creatinine enrichment in the urine was achieved by 30.7 ± 11.2 h. Mean steady-state enrichment in urine provided muscle mass estimates that correlated well with MRI estimates for all subjects (r = 0.868, P creatine dose determined by urine D3-creatinine enrichment provides an estimate of total body muscle mass strongly correlated with estimates from serial MRI with less bias than total lean body mass assessment by DXA.

  2. Honey adulteration detection using liquid chromatography/ elemental analysis-isotope ratio mass spectrometry%液相色谱/元素分析-同位素比值质谱联用法鉴定蜂蜜掺假

    Institute of Scientific and Technical Information of China (English)

    费晓庆; 吴斌; 沈崇钰; 丁涛; 李丽花; 路颖

    2011-01-01

    A new method for honey adulteration detection using liquid chromatography/elemental analysis-isotope ratio mass spectrometry (LC/EA-IRMS) was developed. Based on the individual δ13C values detected for 38 authentic honey samples, the limits for the authentic honey samples were proposed: the δ13 C difference between protein and honey ( Δδ13 Cp-H ) should be higher or equal to than -0.95‰, the δ13C difference between fructose and glucose ( Δδ13 CF-G ) should be from -0. 64‰ to 0. 53‰, and the maximum difference of δ13C values between all the components ( Δδ13Cmax ) should be lower than 2.09‰. Based on the above criteria, the 58 positive samples spiked with C4 or C3 plant sugar syrup were confirmed by LC/EA-IRMS method from 150 commercial honey samples, while only 7 samples spiked with C4 plant sugar syrup were confirmed by the official EA-IRMS method. The proposed method represents a significant improvement in comparing with the official EA-IRMS method.%采用液相色谱/元素分析-同位素比值质谱联用法(LC/EA-IRMS)对国内蜂蜜掺假情况进行了研究.基于测定得到的38个纯正蜂蜜样品的碳同位素δ13C值数据,提出了纯正蜂蜜样品的δ13C值要求:蛋白质和蜂蜜的δ13C差值(Δδ13CP-H)≥-0.95‰,果糖和葡萄糖的δ13C差值(Δδ13CF-G)在-0.64‰至0.53‰范围内,各个组分间的δ13C最大差值(Δδ13Cmax)<2.09‰.对150个日常检测样品、蜂农和蜂蜜供应商的蜂蜜样品分别采用本文建立的LC/EA-IRMS和国家标准方法(EA-IRMS)进行鉴定,LC/EA-IRMS方法检出58个掺有C3或C4植物糖浆的阳性样品,而EA-IRMS方法仅检出7个掺有C4植物糖浆的阳性样品,可见新方法大大提高了对蜂蜜掺假的鉴别能力.

  3. Dilute Acid and Autohydrolysis Pretreatment

    Science.gov (United States)

    Yang, Bin; Wyman, Charles E.

    Exposure of cellulosic biomass to temperatures of about 120-210°C can remove most of the hemicellulose and produce cellulose-rich solids from which high glucose yields are possible with cellulase enzymes. Furthermore, the use of dilute sulfuric acid in this pretreatment operation can increase recovery of hemicellulose sugars substantially to about 85-95% of the maximum possible versus only about 65% if no acid is employed. The use of small-diameter tubes makes it possible to employ high solids concentrations similar to those preferred for commercial operations, with rapid heat-up, good temperature control, and accurate closure of material balances. Mixed reactors can be employed to pretreat larger amounts of biomass than possible in such small-diameter tubes, but solids concentrations are limited to about 15% or less to provide uniform temperatures. Pretreatment of large amounts of biomass at high solids concentrations is best carried out using direct steam injection and rapid pressure release, but closure of material balances in such “steam gun” devices is more difficult. Although flow of water alone or containing dilute acid is not practical commercially, such flow-through configurations provide valuable insight into biomass deconstruction kinetics not possible in the batch tubes, mixed reactors, or steam gun systems.

  4. 稳定同位素稀释-气相色谱质谱联用法测定水产品中甲基汞和乙基汞%Determination of Methylmercury and Ethylmercury in Aquatic Products by Gas Chromatography-Mass Spectrometry with Stable Isotope-Labelled Internal Standard

    Institute of Scientific and Technical Information of China (English)

    张秀尧; 蔡欣欣; 张晓艺

    2014-01-01

    A method for the determination of methylmercury ( MeHg ) and ethylmercury ( EtHg ) in aquatic products was developed using gas chromatography-mass spectrometry with stable isotope-labelled internal standard. After ultrasonication assisted hydrochloric acid extraction, MeHg and EtHg in samples were extracted into toluene under the presence of sodium chloride and then back-extracted into cysteine aqueous solution. The MeHg and EtHg were released from their complexes with cysteine by adding cupric ions, and then derived with sodium tetraphenylborate. Under the optimal chromatographic conditions, MeHgPh and EtHgPh, the resulting derivatives, were separated completely on a DB-5MS capillary column and detected by electron impact ionization mass spectrometry in the selective ion monitoring ( SIM) mode, and quantified by a stable isotope dilution method using the d3-methylmercury as internal standard. The calibration curves were linear in the range of 1-500 μg/L of MeHg and EtHg. Concentration of 0. 828 mg Hg/kg with relative standard deviation ( RSD ) of 3 . 2% ( n=6 ) was obtained for MeHg in GBW 10029 . This was in good agreement with the certified values of (0. 84±0. 03) mg Hg/kg. The average recoveries were 94%-101% and 81%-104% for MeHg and EtHg spiked in aquatic samples, with RSDs of 1. 9%-4. 7% and 3. 1%-8. 2%(n=6), respectively. The limits of detection (S/N=3) of the two targets were 0. 1-0. 3μg/kg. This method was sensitive, accurate and could meet the demand of the determination of methylmercury and ethylmercury in aquatic products.%建立了测定水产品中甲基汞和乙基汞的气相色谱质谱联用分析方法。采用6.0 mol/L HCl超声辅助提取,在NaCl存在下,提取液中甲基汞和乙基汞可被甲苯萃取,再用半胱氨酸反萃取,加入CuSO4释放出的甲基汞和乙基汞与四苯硼钠反应,生成甲基苯基汞和乙基苯基汞,经DB-5MS毛细柱分离,选择离子监测方式( SIM)质谱检测,以d3-甲基汞作为内标的稳

  5. Gas chromatography

    Science.gov (United States)

    Guiochon, Georges; Guillemin, Claude L.

    1990-11-01

    Gas chromatography is a powerful separation technique for gas and vapor mixtures. Combining separation and on-line detection permits accurate quantitative analysis of complex mixtures, including traces of compounds down to parts per trillions in some particular cases. The importance of gas chromatography in quality control and process control in the chemical and drug industry, in environmental pollution investigations and in clinical analysis is critical. The principles of the technique are discussed, the main components of a gas chromatograph are described and some idea of the importance of the applications is given.

  6. A closed cycle 3He- 4He dilution refrigerator insensitive to gravity

    Science.gov (United States)

    Martin, Florian; Vermeulen, Gerard; Camus, Philippe; Benoit, Alain

    2010-09-01

    The cooling power and the lifetime of an open cycle dilution refrigerator as developed for the Planck mission (100 nW at 100 mK during 30 months) are limited by the quantity of the helium isotopes carried on the satellite at launch, because the helium mixture obtained after the dilution process is rejected into space. Future space missions require to increase the cooling power and lifetime significantly (1 μW at 50 mK during 5 years). Therefore we are extending the open cycle dilution refrigerator with a helium isotope separator operating at 1 K to close the cycle. A first prototype to demonstrate the principle of the closed cycle dilution refrigerator has been tested and a cooling power of 1 μW at temperatures below 60 mK has been obtained. We present the apparatus and the experimental results and give some elements for its integration in a complete cooling chain. The advantages (continuous operation, absence of magnetic field, less weight) of a closed cycle dilution refrigerator with respect to an adiabatic demagnetization refrigerator are also discussed.

  7. Green chromatography.

    Science.gov (United States)

    Płotka, Justyna; Tobiszewski, Marek; Sulej, Anna Maria; Kupska, Magdalena; Górecki, Tadeusz; Namieśnik, Jacek

    2013-09-13

    Analysis of organic compounds in samples characterized by different composition of the matrix is very important in many areas. A vast majority of organic compound determinations are performed using gas or liquid chromatographic methods. It is thus very important that these methods have negligible environmental impact. Chromatographic techniques have the potential to be greener at all steps of the analysis, from sample collection and preparation to separation and final determination. The paper summarizes the approaches used to accomplish the goals of green chromatography. While complete elimination of sample preparation would be an ideal approach, it is not always practical. Solventless extraction techniques offer a very good alternative. Where solvents must be used, the focus should be on the minimization of their consumption. The approaches used to make chromatographic separations greener differ depending on the type of chromatography. In gas chromatography it is advisable to move away from using helium as the carrier gas because it is a non-renewable resource. GC separations using low thermal mass technology can be greener because of energy savings offered by this technology. In liquid chromatography the focus should be on the reduction of solvent consumption and replacement of toxic and environmentally hazardous solvents with more benign alternatives. Multidimensional separation techniques have the potential to make the analysis greener in both GC and LC. The environmental impact of the method is often determined by the location of the instrument with respect to the sample collection point.

  8. Ion Chromatography.

    Science.gov (United States)

    Mulik, James D.; Sawicki, Eugene

    1979-01-01

    Accurate for the analysis of ions in solution, this form of analysis enables the analyst to directly assay many compounds that previously were difficult or impossible to analyze. The method is a combination of the methodologies of ion exchange, liquid chromatography, and conductimetric determination with eluant suppression. (Author/RE)

  9. Rapid accurate isotopic measurements on boron in boric acid and boron carbide.

    Science.gov (United States)

    Duchateau, N L; Verbruggen, A; Hendrickx, F; De Bièvre, P

    1986-04-01

    A procedure is described whereby rapid and accurate isotopic measurements can be performed on boron in boric acid and boron carbide after fusion of these compounds with calcium carbonate. It allows the determination of the isotopic composition of boron in boric acid and boron carbide and the direct assay of boron or the (10)B isotope in boron carbide by isotope-dilution mass spectrometry.

  10. Deuterium dilution technique for body composition assessment: resolving methodological issues in children with moderate acute malnutrition

    DEFF Research Database (Denmark)

    Fabiansen, Christian; Yaméogo, Charles W; Devi, Sarita

    2017-01-01

    Childhood malnutrition is highly prevalent and associated with high mortality risk. In observational and interventional studies among malnourished children, body composition is increasingly recognised as a key outcome. The deuterium dilution technique has generated high-quality data on body...... composition in studies of infants and young children in several settings, but its feasibility and accuracy in children suffering from moderate acute malnutrition requires further study. Prior to a large nutritional intervention trial among children with moderate acute malnutrition, we conducted pilot work...... quality when using the deuterium dilution technique in malnutrition studies in field conditions, and may encourage a wider use of isotope techniques....

  11. Leatherback Isotopes

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — SWFSC is currently working on a project identifying global marine isotopes using leatherback turtles (Dermochelys coriacea) as the indicator species. We currently...

  12. Confirmatory method for the determination of nitroimidazoles in milk by liquid chromatography - tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Mitrowska Kamila

    2014-12-01

    Full Text Available A multiresidue method for the determination of seven nitroimidazoles and their hydroxy metabolites in milk was developed. Milk samples were extracted with acetonitrile and cleaned up on strong cation-exchange solid phase extraction cartridges. Evaporated to dryness first, the extracts obtained were then reconstituted in 0.1% formic acid and injected onto a liquid chromatography-tandem mass spectrometer (LC-MS/MS. The separation of analytes was achieved on gradient mode using a C18 column and a mobile phase consisting of 0.1% formic acid in acetonitrile and 0.1% formic acid in water. Multiple reaction monitoring mode was set for the MS/MS with positive electrospray ionisation. For quantification, the isotope dilution method was used with isotopically labeled analogues of the target analytes. The method was evaluated entirely in accordance with EU Commission Decision 2002/657/EC and all validation criteria were in the required ranges. The method can easily detect and confirm metronidazole, dimetridazole, ronidazole, ipronidazole, and their hydroxy metabolites below the recommended concentration level of 3 μg/kg. The decision limits and detection capabilities ranged from 0.11 μg/kg to 0.22 μg/kg and from 0.19 μg/kg to 0.37 μg/kg respectively. The overall recoveries were between 96.6% and 105.2% with a good coefficient of variation, less than 8.7% under within-laboratory reproducibility conditions.

  13. Isotopic chirality

    Energy Technology Data Exchange (ETDEWEB)

    Floss, H.G. [Univ. of Washington, Seattle, WA (United States)

    1994-12-01

    This paper deals with compounds that are chiral-at least in part, due to isotope substitution-and their use in tracing the steric course of enzyme reaction in vitro and in vivo. There are other applications of isotopically chiral compounds (for example, in analyzing the steric course of nonenzymatic reactions and in probing the conformation of biomolecules) that are important but they will not be discussed in this context.

  14. Isotopic Paleoclimatology

    Science.gov (United States)

    Bowen, R.

    Paleotemperature scales were calculated by H. C. Urey and others in the 1950s to assess past temperatures, and later work using the stable isotopes of oxygen, hydrogen, and carbon employed standards such as Peedee belemnite (PDB) and Standard Mean Ocean Water (SMOW). Subsequently, subjects as diverse as ice volume and paleotemperatures, oceanic ice and sediment cores, Pleistocene/Holocene climatic changes, and isotope chronostratigraphy extending back to the Precambrian were investigated.

  15. USE OF STABLE ISOTOPES IN ENVIRONMENTAL AND FORENSIC GEOCHEMISTRY STUDIES

    Science.gov (United States)

    Stable carbon and hydrogen isotopes have been used for many decades in the petroleum industry, but the development of combined gas chromatography-isotope ratio mass spectrometry (GCIRMS) has led to a virtual explosion in application of this technique not only in petroleum explora...

  16. Determination of terbuthylazine and desethylterbuthylazine in human urine and hair samples by eletrospray ionization-liquid chromatography/triple quadrupole mass spectrometry.

    Science.gov (United States)

    Mercadante, Rosa; Polledri, Elisa; Fustinoni, Silvia

    2012-08-01

    Terbuthylazine (TBA) is a widely applied herbicide and an environmental contaminant. Following its use, humans, such as agricultural workers and rural residents, may be exposed. An isotope-dilution liquid chromatography coupled to electrospray-tandem mass spectrometry method for the determination of TBA, and its metabolite desethylterbuthylazine (DET) in human urine and hair was developed and validated. Under the optimised conditions, analytes were extracted from urine using a solid phase cartridge or from hair by sonication in methanol. Analytes were separated using a C18 reversed-phase chromatographic column and quantified, after positive ionization using a heated electrospray source, by a triple quadrupole mass detector in the selected reaction monitoring mode. Validation showed linear dynamic ranges up to 100 μg/L or 5.00 ng/mg hair, inter- and intra-run precisions <7%, and accuracies within 12% of spiked concentrations. Limits of quantification were 0.25 μg/L in urine and 0.01 ng/mg hair for both TBA and DET. Matrix effect evaluation showed that the isotope dilution approach allowed for the control of bias sources. TBA and DET were determined in specimens of agriculture workers exposed to TBA using the validated method. Hair samples contained TBA levels in the low nanogram per milligram range, and urine samples contained DET levels in the low microgram per liter range. Conversely, TBA levels in urine samples and DET levels in hair samples were always below the limit of quantification.

  17. Determination of therapeutic γ-aminobutyric acid analogs in forensic whole blood by hydrophilic interaction liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Sørensen, Lambert K; Hasselstrøm, Jørgen B

    2014-05-01

    Vigabatrin, pregabalin, gabapentin and baclofen are γ-aminobutyric acid analogs that are used in the treatment of epileptic seizures (vigabatrin, pregabalin and gabapentin) and spasticity (baclofen). The intake of these drugs may induce adverse reactions and impair the ability of an individual to drive a vehicle. There have also been reports of cases of intoxication and fatalities from overdoses. For rapid and accurate quantification of these drugs in forensic cases, an ultraperformance liquid chromatography tandem mass spectrometry method using pneumatically assisted electrospray ionization has been developed. The technique has been validated on both ante- and postmortem human whole blood. The protein in the blood samples was removed by the addition of a mixture of methanol and acetonitrile, and the extract was ultrafiltered and diluted with acetonitrile. The separation was performed by hydrophilic interaction liquid chromatography. Calibration of the system was achieved through use of matrix-matched calibrants combined with isotope dilution. The lower limits of quantification were 0.02-0.04 mg/L, and the relative intra-laboratory reproducibility standard deviations were 89%. The trueness expressed as the relative bias of the test results was within ±7% at concentrations of 1-40 mg/L for vigabatrin, pregabalin and gabapentin and of 0.1-4 mg/L for baclofen.

  18. Inductively coupled plasma mass spectrometry for stable isotope metabolic tracer studies of living systems

    Energy Technology Data Exchange (ETDEWEB)

    Luong, Elise [Iowa State Univ., Ames, IA (United States)

    1999-05-10

    This dissertation focuses on the development of methods for stable isotope metabolic tracer studies in living systems using inductively coupled plasma single and dual quadrupole mass spectrometers. Sub-nanogram per gram levels of molybdenum (Mo) from human blood plasma are isolated by the use of anion exchange alumina microcolumns. Million-fold more concentrated spectral and matrix interferences such as sodium, chloride, sulfate, phosphate, etc. in the blood constituents are removed from the analyte. The recovery of Mo from the alumina column is 82 ± 5% (n = 5). Isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) is utilized for the quantitative ultra-trace concentration determination of Mo in bovine and human blood samples. The average Mo concentration in reference bovine serum determined by this method is 10.2 ± 0.4 ng/g, while the certified value is 11.5 ± 1.1 ng/g (95% confidence interval). The Mo concentration of one pool of human blood plasma from two healthy male donors is 0.5 ± 0.1 ng/g. The inductively coupled plasma twin quadrupole mass spectrometer (ICP-TQMS) is used to measure the carbon isotope ratio from non-volatile organic compounds and bio-organic molecules to assess the ability as an alternative analytical method to gas chromatography combustion isotope ratio mass spectrometry (GC-combustion-IRMS). Trytophan, myoglobin, and β-cyclodextrin are chosen for the study, initial observation of spectral interference of 13C+ with 12C 1H+ comes from the incomplete dissociation of myoglobin and/or β-cyclodextrin.

  19. Isotope pattern deconvolution as rising tool for isotope tracer studies in environmental research

    Science.gov (United States)

    Irrgeher, Johanna; Zitek, Andreas; Prohaska, Thomas

    2014-05-01

    During the last decade stable isotope tracers have emerged as versatile tool in ecological research. Besides 'intrinsic' isotope tracers caused by the natural variation of isotopes, the intentional introduction of 'extrinsic' enriched stable isotope tracers into biological systems has gained significant interest. Hereby the induced change in the natural isotopic composition of an element allows amongst others for studying the fate and fluxes of metals, trace elements and species in organisms or provides an intrinsic marker or tag of particular biological samples. Due to the shoreless potential of this methodology, the number of publications dealing with applications of isotope (double) spikes as tracers to address research questions in 'real world systems' is constantly increasing. However, some isotope systems like the natural Sr isotopic system, although potentially very powerful for this type of application, are still rarely used, mainly because their adequate measurement/determination poses major analytical challenges; as e.g. Sr is available in significant amounts in natural samples. In addition, biological systems underlie complex processes such as metabolism, adsorption/desorption or oxidation/reduction. As a consequence, classic evaluation approaches such as the isotope dilution mass spectrometry equation are often not applicable because of the unknown amount of tracer finally present in the sample. Isotope pattern deconvolution (IPD), based on multiple linear regression, serves as simplified alternative data processing strategy to double spike isotope dilution calculations. The outstanding advantage of this mathematical tool lies in the possibility of deconvolving the isotope pattern in a spiked sample without knowing the quantities of enriched isotope tracer being incorporated into the natural sample matrix as well as the degree of impurities and species-interconversion (e.g. from sample preparation). Here, the potential of IPD for environmental tracer

  20. Turbulence of Dilute Polymer Solution

    CERN Document Server

    Xi, Heng-Dong; Xu, Haitao

    2013-01-01

    In fully developed three dimensional fluid turbulence the fluctuating energy is supplied at large scales, cascades through intermediate scales, and dissipates at small scales. It is the hallmark of turbulence that for intermediate scales, in the so called inertial range, the average energy flux is constant and independent of viscosity [1-3]. One very important question is how this range is altered, when an additional agent that can also transport energy is added to the fluid. Long-chain polymers dissolved at very small concentrations in the fluid are such an agent [4,5]. Based on prior work by de Gennes and Tabor [6,7] we introduce a theory that balances the energy flux through the turbulent cascade with that of the energy flux into the elastic degrees of freedom of the dilute long-chain polymer solution. We propose a refined elastic length scale, $r_\\varepsilon$, which describes the effect of polymer elasticity on the turbulence energy cascade. Our experimental results agree excellently with this new energy ...

  1. Storm Sewage Dilution in Smaller Streams

    DEFF Research Database (Denmark)

    Larsen, Torben; Vestergaard, Kristian

    1987-01-01

    A numerical model has been used to show how dilution in smaller streams can be effected by unsteady hydraulic conditions caused by a storm sewage overflow.......A numerical model has been used to show how dilution in smaller streams can be effected by unsteady hydraulic conditions caused by a storm sewage overflow....

  2. Clinical applications of gas chromatography and gas chromatography-mass spectrometry of steroids

    NARCIS (Netherlands)

    Wolthers, BG; Kraan, GPB

    1999-01-01

    This review article underlines the importance of gas chromatography-mass spectrometry (GC-MS) for determination of steroids in man. The use of steroids labelled with stable isotopes as internal standard and subsequent analysis by GC-MS yields up to now the only reliable measurement of steroids in

  3. Modeling of Dilute Polymer Solutions in Confined Space

    DEFF Research Database (Denmark)

    Wang, Yanwei

    2009-01-01

    to macromolecules is critical to the design and application of those devices. Our primary interest is to provide an understanding of the separation principle of polymers in size exclusion chromatography (SEC), where under ideal conditions the polymer concentration is low, and detailed enthalpic interactions...... of polymers in SEC, one may reach a conclusion that SEC fractionates polymers based on the steric exclusion radius, Rs . The CABS method is further applied to determine the depletion profiles of dilute polymer solutions confined to a slit or near an inert wall. We show that the entire spatial density...... that (i) the depletion layer thickness, 6, is the same no matter which reference point is used to describe the depletion profile, and (ii) the value of 6 equals the steric exclusion radius, Rs , of the macromolecule in free solution. Both results hold not only for ideal polymers as has been noticed before...

  4. Yield effects on 2-methoxy-3-isobutylpyrazine concentration in cabernet sauvignon using a solid phase microextraction gas chromatography/mass spectrometry method.

    Science.gov (United States)

    Chapman, Dawn M; Thorngate, John H; Matthews, Mark A; Guinard, Jean-Xavier; Ebeler, Susan E

    2004-08-25

    A rapid and automated solid phase microextraction (SPME) stable isotope dilution gas chromatography/mass spectrometry (GC-MS) method for 2-methoxy-3-isobutylpyrazine (MIBP) quantification in red wine was developed. Wines with 30% (w/v) NaCl and 2-methoxy-(2)H(3)-3-isobutylpyrazine internal standard were sampled with a 2 cm divinylbenzene/carboxen/poly(dimethylsiloxane) SPME fiber for 30 min at 40 degrees C and analyzed by GC-MS. The method was used to measure MIBP concentrations in Cabernet Sauvignon wines that were produced from six winter pruning treatments over two vintages. MIBP concentrations were significantly negatively correlated with buds per vine. In addition, the MIBP concentration was directly related to sensory vegetal intensity ratings obtained by descriptive analysis.

  5. Determination of VX-G analogue in red blood cells via gas chromatography-tandem mass spectrometry following an accidental exposure to VX.

    Science.gov (United States)

    McGuire, Jeffrey M; Taylor, James T; Byers, Christopher E; Jakubowski, Edward M; Thomson, Sandra M

    2008-01-01

    A sensitive method for determining exposure to the chemical warfare agent VX is described in which the biomarker ethyl methylphosphonofluoridate (VX-G) is measured in red blood cells (RBCs) following treatment with fluoride ion using isotope-dilution gas chromatography-tandem mass spectrometry. The analyte was isolated via solid-phase extraction and detected using ammonia chemical ionization in the multiple reaction monitoring mode. A good linear relationship was obtained in the quantitative concentration range of 4 ng/mL to 1000 ng/mL with an absolute detection limit of VX vapor. Detection and quantitation of VX-G were possible in samples taken as late as 27 days following exposure.

  6. Prenatal diagnosis of methylmalonic aciduria by measuring methylmalonic acid in dried amniotic fluid on filter paper using gas chromatography-mass spectrometry.

    Science.gov (United States)

    Inoue, Yoshito; Ohse, Morimasa

    2011-06-01

    Methylmalonic aciduria is a common inherited metabolic disorder. Methylmalonic acid (MMA), a key indicator of methylmalonic aciduria, increases in the amniotic fluid of affected fetuses. For prenatal diagnosis, the MMA in amniotic fluid can be measured by stable-isotope dilution gas chromatography-mass spectrometry. Here, we quantified the MMA in cell-free amniotic fluid samples that had been dried on filter paper and transported at ambient temperatures, and compared the results with data obtained from the original amniotic fluid. Our results indicated that the filter paper method was reproducible and accurate enough to be applied to clinical analysis. We also used the filter paper method to screen at-risk fetuses and obtained a clear diagnosis in each case. We conclude that our method enables the prenatal diagnosis of methylmalonic aciduria using practical procedures and a simplified method for transporting the samples.

  7. Optimization and validation of a taste dilution analysis to characterize wine taste.

    Science.gov (United States)

    Lopez, R; Mateo-Vivaracho, L; Cacho, J; Ferreira, V

    2007-08-01

    A procedure for the general taste dilution analysis (TDA) of wine has been optimized and applied to characterize the tastants of 5 different wines. Samples are concentrated first by vacuum distillation at 20 degrees C to obtain a dearomatized concentrate. Such concentrate is redissolved in water and injected in a semipreparative C18-high performance liquid chromatography (HPLC) column. The effluent is separated in fractions that are collected and concentrated by vacuum distillation. Sequential dilutions of the fractions are further evaluated by a sensory panel to assess the intensity of the basic tastes and in-mouth sensations. Fractions were also submitted to HPLC-mass spectrometry (MS) analysis to screen for known tastants of wines. The Taste Dilution chromatograms showed that taste differences between wines are mainly located in fractions 1, 2, and 6, and are mainly related to bitterness and astringency. Different aspects of the method setup and of its reliability are evaluated and discussed.

  8. Gas Chromatography

    Science.gov (United States)

    Qian, Michael C.

    Gas chromatography (GC) has many applications in the analysis of food products. GC has been used for the determination of fatty acids, triglycerides, cholesterol, gases, water, alcohols, pesticides, flavor compounds, and many more. While GC has been used for other food components such as sugars, oligosaccharides, amino acids, peptides, and vitamins, these substances are more suited to analysis by high performance liquid chromatography. GC is ideally suited to the analysis of volatile substances that are thermally stable. Substances such as pesticides and flavor compounds that meet these criteria can be isolated from a food and directly injected into the GC. For compounds that are thermally unstable, too low in volatility, or yield poor chromatographic separation due to polarity, a derivatization step must be done before GC analysis. The two parts of the experiment described here include the analysis of alcohols that requires no derivatization step, and the analysis of fatty acids which requires derivatization. The experiments specify the use of capillary columns, but the first experiment includes conditions for a packed column.

  9. Americium and plutonium separation by extraction chromatography for determination by accelerator mass spectrometry.

    Science.gov (United States)

    Kazi, Zakir H; Cornett, Jack R; Zhao, Xaiolei; Kieser, Liam

    2014-06-04

    A simple method was developed to separate Pu and Am using single column extraction chromatography employing N,N,N',N'-tetra-n-octyldiglycolamide (DGA) resin. Isotope dilution measurements of Am and Pu were performed using accelerator mass spectrometry (AMS) and alpha spectrometry. For maximum adsorption Pu was stabilized in the tetra valent oxidation state in 8M HNO3 with 0.05 M NaNO2 before loading the sample onto the resin. Am(III) was adsorbed also onto the resin from concentrated HNO3, and desorbed with 0.1 M HCl while keeping the Pu adsorbed. The on-column reduction of Pu(IV) to Pu(III) with 0.02 M TiCl3 facilitated the complete desorption of Pu. Interferences (e.g. Ca(2+), Fe(3+)) were washed off from the resin bed with excess HNO3. Using NdF3, micro-precipitates of the separated isotopes were prepared for analysis by both AMS and alpha spectrometry. The recovery was 97.7±5.3% and 95.5±4.6% for (241)Am and (242)Pu respectively in reagents without a matrix. The recoveries of the same isotopes were 99.1±6.0 and 96.8±5.3% respectively in garden soil. The robustness of the method was validated using certified reference materials (IAEA 384 and IAEA 385). The measurements agree with the certified values over a range of about 1-100 Bq kg(-1). The single column separation of Pu and Am saves reagents, separation time, and cost.

  10. Specific Carbon Isotopic Analysis of n-Alkanes in Soils by Gas Chromatography-Isotope Ratio Mass Spectrometry with 5A Molecular Sieve Adsorption and Mixed Solvent Elution%5A分子筛吸附混合溶剂洗脱-气相色谱-同位素质谱分析土壤中正构烷烃单体碳同位素

    Institute of Scientific and Technical Information of China (English)

    张逐月; 刘美美; 谢曼曼; 王道聪; 凌媛; 尚文郁; 刘舒波; 岑况; 孙青

    2012-01-01

    利用5A分子筛吸附,环己烷-正戊烷混合溶剂洗脱分离富集正构烷烃,用气相色谱法测定正构烷烃含量,气相色谱-气体同位素质谱( GC -C- IRMS)测定土壤样品中正构烷烃单体碳同位素.实验优化了5A分子筛用量和洗脱剂的比例,需要络合的正构烷烃的量与分子筛加入量呈线性关系,络合xmg的正构烷烃,需加入2.75xg分子筛,络合环己烷-正戊烷最佳比例为9∶91.探讨了络合过程中5A分子筛对不同链长正构烷烃的络合规律,短链正构烷烃被5A分子筛优先吸附,长链正构烷烃的络合相对滞后.正构烷烃的络合洗脱回收率为44% ~ 72%,精密度(RSD,n=6)为4%~8%;正构烷烃单体碳同位素分析精度为0.04‰~0.38‰( 1σ).采用5A分子筛净化混合溶剂洗脱方法,分析加油站附近的实际土壤样品,未分峰基本消除,获得良好的净化效果,满足正构烷烃单体碳同位素分析的要求.%n-alkanes were concentrated after separating by a 5A molecular sieve and extracted by a mixture solvent of cyclohexane and n-pentane. In this study, the amount of 5A molecular sieve and the ratios of cyclohexane and n-pentane were optimized as 2.76 g and 9 : 91, respectively. It was discovered that short carbon chain n-alkanes were readily absorbed by a.5A molecular sieve, compared to the long carbon chain n-alkanes. The complexation efficiency is higher for long carbon chain n-alkanes than that of short carbon chain n-alkanes with enough 5A molecular material at higher temperature. In this study, n-alkanes contents were determined by Gas Chromatography ( CC) and compound specific carbon isotope ratios of individual n-alkanes in soil were measured by Gas Chromatography-lsotope Ratio Mass Spectrometry ( GC-IRMS). The recoveries of n-alkanes ranged from44% to 72%c with a precision of 4% - 8%. The accuracies of compound specific carbon isotopes of n-alkanes ranged from 0.04%e to 0. 38%e (1σ). The 5A molecular sieve

  11. The antibacterial activity of diluted Tualang honey

    Directory of Open Access Journals (Sweden)

    N. A. Roslan

    2015-05-01

    Full Text Available Tualang honey (TH is a Malaysian jungle honey obtained from the wild. The honey is produced by the rock bee (Apis dorsata, which builds hives on branches of tall Tualang (Koompassia excelsa (Becc. Taub trees located mainly in the north-western region of Peninsular Malaysia. Limited information is available on the antibacterial mechanism of local honey. The present study was conducted to determine the antibacterial activity of diluted ?Tualang? honey against Escherichia coli (E. coli. Three different Tualang honey concentrations, namely, 20, 30 and 40% were used to examine the effect of diluting Tualang honey on its antibacterial effect towards E. coli. The 40% diluted honey was the most effective in inhibiting the growth of E. coli, followed by honey diluted at 20 and 30%. The high antibacterial activity of honey towards E. Coli was thought to arise from the production of hydrogen peroxide, but requires further study to validate the action.

  12. Flux balance analysis accounting for metabolite dilution.

    Science.gov (United States)

    Benyamini, Tomer; Folger, Ori; Ruppin, Eytan; Shlomi, Tomer

    2010-01-01

    Flux balance analysis is a common method for predicting steady-state flux distributions within metabolic networks, accounting for the growth demand for the synthesis of a predefined set of essential biomass precursors. Ignoring the growth demand for the synthesis of intermediate metabolites required for balancing their dilution leads flux balance analysis to false predictions in some cases. Here, we present metabolite dilution flux balance analysis, which addresses this problem, resulting in improved metabolic phenotype predictions.

  13. The production of stable isotopes in Spain

    Energy Technology Data Exchange (ETDEWEB)

    Urgel, M.; Iglesias, J.; Casas, J.; Saviron, J. M.; Quintanilla, M.

    1965-07-01

    The activities developed in the field of the production of stable isotopes by means of ion-exchange chromatography and thermal diffusion techniques are reported. The first method was used to study the separation of the nitrogen and boron isotopes, whereby the separation factor was determined by the break through method. Values ranging from 1,028 to 1,022 were obtained for the separation factor of nitrogen by using ammonium hydroxide solutions while the corresponding values as obtained for boron amounted to 1,035-1,027 using boric acid solutions. Using ammonium chloride or acetate and sodium borate, respectively, resulted in the obtention of values for the separation factor approaching unity. The isotopic separation has been carried out according to the method of development by displacement. The separation of the isotopes of the noble gases, oxygen, nitrogen and carbon has been accomplished resorting to the method of thermal diffusion. (Author) 16 refs.

  14. Absorção real, perdas endógenas e exigência de fósforo para suínos em final de crescimento, pela técnica da diluição isotópica True absorption and endogenous fecal losses of phosphorus for swine in the final of the growing based on the isotopic dilution techinique

    Directory of Open Access Journals (Sweden)

    J.B. Lopes

    1999-08-01

    Full Text Available Determinaram-se as perdas endógenas mínimas, a exigência de fósforo e a absorção real do fósforo do fosfato bicálcico em suínos no final da fase de crescimento, pela técnica da diluição isotópica. Foram utilizados 20 leitões híbridos comerciais, com peso de 48kg, distribuídos em delineamento experimental de blocos ao acaso com cinco tratamentos, constituídos de dietas com diferentes níveis de P total (0,33, 0,36, 0,47, 0,54 e 0,61%, com quatro repetições. A excreção fecal e urinária, a absorção e a retenção de P foram influenciadas pelos níveis de consumo desse mineral. As perdas endógenas fecais não foram influenciadas pelos níveis de P consumido, indicando que os níveis ingeridos foram insuficientes para atender às exigências de P dos leitões. A biodisponibilidade do fósforo do fosfato bicálcico foi de 74,7% e a exigência de mantença de 10,02mgP/kg p.v./dia.The experiment was carried out to determine the minimum fecal endogenous losses, the P requirement of pigs, and the true P absorption from phosphate dicalcium using pigs in the final of the growing phase through the isotopic dilution technique. Twenty commercial hybrid pigs, 48kg L.W., were arranged in experimental design complete randomized blocks with five treatments and four replications. Treatments consisted of different total P levels: 0.33, 0.36, 0.47, 0.54 and 0.61%. Fecal and urinary P outputs, absorption and retention of P were influenced by P intake; P endogenous losses were not affected by P intake, indicating that dietary P was not enough to achieve P requirements; the P biological availability from dicalcium phosphate was 74.7%; and the daily maintenance dietary requirement for pigs was 10.02mg P/kg L.W.

  15. Quantitation of five organophosphorus nerve agent metabolites in serum using hydrophilic interaction liquid chromatography and tandem mass spectrometry

    Science.gov (United States)

    Hamelin, Elizabeth I.; Schulze, Nicholas D.; Shaner, Rebecca L.; Coleman, Rebecca M.; Lawrence, Richard J.; Crow, Brian S.; Jakubowski, E. M.; Johnson, Rudolph C.

    2015-01-01

    Although nerve agent use is prohibited, concerns remain for human exposure to nerve agents during decommissioning, research, and warfare. Exposure can be detected through the analysis of the hydrolysis products in urine as well as blood. An analytical method to detect exposure to five nerve agents, including VX, VR (Russian VX), GB (sarin), GD (soman) and GF (cyclosarin), through the analysis of the hydrolysis products, which are the primary metabolites, in serum has been developed and characterized. This method uses solid phase extraction coupled with high performance liquid chromatography for separation and isotopic dilution tandem mass spectrometry for detection. An uncommon buffer of ammonium fluoride was used to enhance ionization and improve sensitivity when coupled with hydrophilic interaction liquid chromatography resulting in detection limits from 0.3–0.5 ng/mL. The assessment of two quality control samples demonstrated high accuracy (101–105%) and high precision (5–8%) for the detection of these five nerve agent hydrolysis products in serum. PMID:24633507

  16. Measurement of Stable Carbon and Hydrogen Isotope in White Massive Natural Gas Hydrate by Gas Chromatography-Isotope Ratio Mass Spectrometry%GC-IRMS测定白色块状天然气水合物气体中的碳氢同位素

    Institute of Scientific and Technical Information of China (English)

    雷知生; 曹珺; 刘坚; 程思海; 陈道华

    2015-01-01

    Gas chromatography–isotope ratio mass spectrometry (GC–IRMS)method for measurement of carbon and hydrogen isotope in hydrocarbon gases was established.The hydrocarbon gases were separated by GC and turned to CO2 and H2 in high temperature,then determined by MAT–253 stable isotope spectrometry.The test results of carbon and hydrogen isotope in methane was consitent with its calibration standard value.The standard deviation of detection results of carbon and hydrogen were 0.222‰and 0.950‰,repectively.The method was used to determine the carbon and hydrogen isotope of natural gas hydrate bound gas drilled from Eastern Pearl River Mouth Basin ,theδ13C value was–69.78‰(VPDB),theδD value was–184.4‰(VSMOW).The GC–IRMS method has high accuracy, precision and wide range,it is suitable for determining carbon and hydrogen isotope in marine gas hydrate.%研究了GC–IRMS联用技术测定烃类气体碳氢稳定同位素的方法。利用气相色谱仪将烃类气体各组分分开,通过高温燃烧/裂解转化为CO2和H2,然后导入MAT–253稳定同位素质谱仪进行测试。用该方法测试的标准甲烷气体碳、氢同位素值和其标定值一致,测定结果的相对标准偏差分别为0.222‰和0.950‰。用该法测定了广东沿海珠江口盆地东部海域首次钻获的高纯度天然气水合物样品所释放的烃类气体碳氢稳定同位素值,其中δ13C为–69.78‰(VPDB),δD为–184.4‰(VSMOW)。GC–IRMS法精确度高,可用范围广,适用于海洋天然气水合物样品所释放烃类气体碳氢同位素的测定。

  17. Development of a pair of differential H/D isotope-coded derivatization reagents d(0)/d(3)-4-(1-methyl-1H-phenanthro[9,10-d]imidazol-2-yl)phenlamine and its application for determination of aldehydes in selected aquatic products by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Sun, Zhiwei; Wang, Xiaoxiang; Cai, Yiping; Fu, Junqing; You, Jinmao

    2014-03-01

    A new pair of derivatization reagents, d0-4-(1-methyl-1H-phenanthro[9,10-d]imidazol-2-yl)phenlamine (d0-MPIA) and d3-4-(1-methyl-1H-phenanthro[9,10-d]imidazol-2-yl)phenlamine (d3-MPIA) have been designed and synthesized. It was successfully used to label aliphatic aldehydes and the aldehyde derivatives were analyzed by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The new isotope-coded reagents could easily label aldehydes under acidic conditions in the presence of NaCNBH3. The target derivatives exhibited intense [M+H](+) and regular product ions with electrospray ionization source in positive mode. The d0/d3-MPIA-aldehydes were monitored by the transitions of [M+H](+)→m/z 322 and [M+H](+)→m/z 165, and the obtained detection limits were in the range of 0.18-15.9 pg/mL at signal to noise ratio of 3. The global isotope internal standard technology was employed for quantification analysis with d3-MPIA-aldehyde as internal standard for corresponding d0-MPIA-aldehyde. Excellent linear responses for relative quantification were observed in the range of 1/10-10/1 with coefficients >0.998. The developed method has been applied to the quantification of aliphatic aldehydes in selected aquatic products with RSD85.2%. © 2013 Elsevier B.V. All rights reserved.

  18. Instrumentation: Ion Chromatography.

    Science.gov (United States)

    Fritz, James S.

    1987-01-01

    Discusses the importance of ion chromatography in separating and measuring anions. The principles of ion exchange are presented, along with some applications of ion chromatography in industry. Ion chromatography systems are described, as well as ion pair and ion exclusion chromatography, column packings, detectors, and programming. (TW)

  19. Comparison of Dilution, Filtration, and Microwave Digestion Sample Pretreatments in Elemental Profiling of Wine by ICP-MS.

    Science.gov (United States)

    Godshaw, Joshua; Hopfer, Helene; Nelson, Jenny; Ebeler, Susan E

    2017-09-25

    Wine elemental composition varies by cultivar, geographic origin, viticultural and enological practices, and is often used for authenticity validation. Elemental analysis of wine by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is challenging due to the potential for non-spectral interferences and plasma instability arising from organic matrix components. Sample preparation mitigates these interferences, however, conflicting recommendations of best practices in ICP-MS analysis of wine have been reported. This study compared direct dilution, microwave-assisted acid digestion, and two filtration sample pretreatments, acidification prior to filtration and filtration followed by acidification, in elemental profiling of one white and three red table wines by ICP-MS. Of 43 monitored isotopes, 37 varied by sample preparation method, with significantly higher results of 17 isotopes in the microwave-digested samples. Both filtration treatments resulted in lower results for 11 isotopes compared to the other methods. Finally, isotope dilution determination of copper based on natural abundances and the (63)Cu:(65)Cu instrument response ratio agreed with external calibration and confirmed a significant sample preparation effect. Overall, microwave digestion did not compare favorably, and direct dilution was found to provide the best compromise between ease of use and result accuracy and precision, although all preparation strategies were able to differentiate the wines.

  20. Order Parameters of the Dilute A Models

    CERN Document Server

    Warnaar, S O; Seaton, K A; Nienhuis, B

    1993-01-01

    The free energy and local height probabilities of the dilute A models with broken $\\Integer_2$ symmetry are calculated analytically using inversion and corner transfer matrix methods. These models possess four critical branches. The first two branches provide new realisations of the unitary minimal series and the other two branches give a direct product of this series with an Ising model. We identify the integrable perturbations which move the dilute A models away from the critical limit. Generalised order parameters are defined and their critical exponents extracted. The associated conformal weights are found to occur on the diagonal of the relevant Kac table. In an appropriate regime the dilute A$_3$ model lies in the universality class of the Ising model in a magnetic field. In this case we obtain the magnetic exponent $\\delta=15$ directly, without the use of scaling relations.

  1. 21 CFR 864.5240 - Automated blood cell diluting apparatus.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated blood cell diluting apparatus. 864.5240... § 864.5240 Automated blood cell diluting apparatus. (a) Identification. An automated blood cell diluting apparatus is a fully automated or semi-automated device used to make appropriate dilutions of a blood...

  2. Dynamic Dilution Effects in Polymeric Networks

    DEFF Research Database (Denmark)

    Skov, Anne Ladegaard; Sommer-Larsen, Peter; Hassager, Ole

    2006-01-01

    processes, namely the reptation of linear species within the network and the arm withdrawal process of star arms in the sol fraction and of dangling single-chain ends attached to the network. The relaxation spectra are influenced by the stoichiometry to a large extent due to dynamic dilution effects caused...... by the change in the amount of dangling arms and solubles with stoichiometry. The star arm relaxation is suppressed by washing out the sol fraction which is seen as a clear example of the dynamic dilution effect arising from the small amount of non-reactive PDMS....

  3. Americium and plutonium separation by extraction chromatography for determination by accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kazi, Zakir H. [Department of Earth Science, University of Ottawa, 140 Louis Pasteur Avenue, Ottawa K1N 6N5 (Canada); Cornett, Jack R., E-mail: jack.cornett@uottawa.ca [Department of Earth Science, University of Ottawa, 140 Louis Pasteur Avenue, Ottawa K1N 6N5 (Canada); Zhao, Xaiolei; Kieser, Liam [Department of Physics, University of Ottawa, 140 Louis Pasteur Avenue, Ottawa K1N 6N5 (Canada)

    2014-06-01

    Highlights: • Am and Pu were adsorbed and separated using a single extraction chromatography DGA column. • Pu was eluted from the column completely using on-column reduction of Pu(IV) to Pu(III). • ²⁴¹Am and 239,240Pu measurements by accelerator mass spectrometry (AMS) agree with the certified values in two SRMs. Abstract: A simple method was developed to separate Pu and Am using single column extraction chromatography employing N,N,N',N'-tetra-n-octyldiglycolamide (DGA) resin. Isotope dilution measurements of Am and Pu were performed using accelerator mass spectrometry (AMS) and alpha spectrometry. For maximum adsorption Pu was stabilized in the tetra valent oxidation state in 8 M HNO₃ with 0.05 M NaNO₂ before loading the sample onto the resin. Am(III) was adsorbed also onto the resin from concentrated HNO₃, and desorbed with 0.1 M HCl while keeping the Pu adsorbed. The on-column reduction of Pu(IV) to Pu(III) with 0.02 M TiCl₃ facilitated the complete desorption of Pu. Interferences (e.g. Ca²⁺, Fe³⁺) were washed off from the resin bed with excess HNO₃. Using NdF₃, micro-precipitates of the separated isotopes were prepared for analysis by both AMS and alpha spectrometry. The recovery was 97.7 ± 5.3% and 95.5 ± 4.6% for ²⁴¹Am and ²⁴²Pu respectively in reagents without a matrix. The recoveries of the same isotopes were 99.1 ± 6.0 and 96.8 ± 5.3% respectively in garden soil. The robustness of the method was validated using certified reference materials (IAEA 384 and IAEA 385). The measurements agree with the certified values over a range of about 1–100 Bq kg⁻¹. The single column separation of Pu and Am saves reagents, separation time, and cost.

  4. On the interference of Kr during carbon isotope analysis of methane using continuous-flow combustion–isotope ratio mass spectrometry

    NARCIS (Netherlands)

    Schmitt, J.; Seth, B.; Bock, M; van der Veen, C.; Möller, L.; Sapart, C.J.; Prokopiou, M.; Sowers, T.; Röckmann, T.; Fischer, H

    2013-01-01

    Stable carbon isotope analysis of methane ( 13C of CH4) on atmospheric samples is one key method to constrain the current and past atmospheric CH4 budget. A frequently applied measurement technique is gas chromatography (GC) isotope ratio mass spectrometry (IRMS) coupled to a combustion-preconcentra

  5. Specificity of synthesis and analysis of molecules labelled with stable isotopes; Specificite des syntheses et analyses des molecules marquees avec les isotopes stables

    Energy Technology Data Exchange (ETDEWEB)

    Noel, J.P. [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. de Biologie Cellulaire et Moleculaire

    1994-12-31

    The various specificities of synthesis with stable isotopes are: unusual raw materials and use of precursors, possibility of producing several isotopomers corresponding to the same chemical compound, involvement of a reaction mechanism in labelling. As a matter of fact, isotopic synthesis are generally more complex than synthesis of non-labelled products. When preparing labelled molecules, it is of importance to avoid any isotopic dilution. Chemical purity for labelled molecules is controlled by various chromatographic techniques and isotopic analysis are carried out by nuclear magnetic resonance and mass spectrometry. 9 figs., 2 tabs.

  6. A gas chromatograph/mass spectrometry method for determining isotopic distributions in organic compounds used in the chemical approach to stable isotope separation

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, A.M.; Spall, W.D.; Smith, B.F.

    1990-01-01

    A variety of gas chromatograph/mass spectrometry (GC/MS) methods have been developed to resolve benzene, benzophenone, anthracene, fluorenone, and their respective stable isotope analogs from other components by gas chromatography. The ratio of stable isotope-labeled material to natural isotopic abundance compounds is determined from the mass spectra averaged across the chromatographic peak. Both total ion and selective ion chromatographic approaches were used for relative data and comparison. 9 refs., 11 tabs.

  7. Confluence Model or Resource Dilution Hypothesis?

    DEFF Research Database (Denmark)

    Jæger, Mads

    Studies on family background often explain the negative effect of sibship size on educational attainment by one of two theories: the Confluence Model (CM) or the Resource Dilution Hypothesis (RDH). However, as both theories – for substantively different reasons – predict that sibship size should...

  8. Variational approach to the dilute Bose gas

    NARCIS (Netherlands)

    Bijlsma, M.; Stoof, H.T.C.

    1997-01-01

    We study the weakly interacting Bose gas in both two and three dimensions using a variational approach. In particular we construct the thermodynamic potential of the gas to within ladder approximation and find by minimization an accurate mean-field description of the dilute Bose gas. Using

  9. A century of indicator dilution technique

    DEFF Research Database (Denmark)

    Henriksen, Jens H; Jensen, Gorm B; Larsson, Henrik B W

    2014-01-01

    This review imparts the history and the present status of the indicator dilution technique with quantitative bolus injection. The first report on flow measurement with this technique appeared 100 years ago. In 1928, the use of intravascular dyes made possible a widespread application in animals...

  10. Serial dilution microchip for cytotoxicity test

    Science.gov (United States)

    Bang, Hyunwoo; Lim, Sun Hee; Lee, Young Kyung; Chung, Seok; Chung, Chanil; Han, Dong-Chul; Chang, Jun Keun

    2004-08-01

    Today's pharmaceutical industry is facing challenges resulting from the vast increases in sample numbers produced by high-throughput screening (HTS). In addition, the bottlenecks created by increased demand for cytotoxicity testing (required to assess compound safety) are becoming a serious problem. We have developed a polymer PDMS (polydimethylsiloxane) based microfluidic device that can perform a cytotoxicity test in a rapid and reproducible manner. The concept that the device includes is well adjustable to automated robots in huge HTS systems, so we can think of it as a potential dilution and delivery module. Cytotoxicity testing is all about the dilution and dispensing of a drug sample. Previously, we made a PDMS based microfluidic device which automatically and precisely diluted drugs with a buffer solution with serially increasing concentrations. This time, the serially diluted drug solution was directly delivered to 96 well plates for cytotoxicity testing. Cytotoxic paclitaxel solution with 2% RPMI 1640 has been used while carrying out cancerous cell based cytotoxicity tests. We believe that this rapid and robust use of the PDMS microchip will overcome the growing problem in cytotoxicity testing for HTS.

  11. Osmosis is not driven by water dilution.

    Science.gov (United States)

    Kramer, Eric M; Myers, David R

    2013-04-01

    There is a misconception among plant scientists that osmosis is driven by the tendency of solutes to dilute water. In this opinion article, we discuss the quantitative and qualitative failures of this view, and go on to review the correct kinetic picture of osmosis as it appears in physics textbooks.

  12. Stable isotopes in pharmacology studies: present and future

    Energy Technology Data Exchange (ETDEWEB)

    Browne, T.R.

    1986-07-01

    Stable-isotope techniques offer advantages over older methods in safety, sensitivity, specificity, and reduction in numbers of subjects required and analytic determinations for some types of pharmacology studies. In addition to their use as internal standards in gas chromatography-mass spectrometry analytic methods, stable isotopes have been successfully employed in studies of absorption, bioavailability, distribution, biotransformation, excretion, metabolite identification, time-dependent and dose-dependent pharmacokinetic changes, drug interactions, pharmacologic changes during pregnancy, mutagenicity, and teratogenicity. 32 references.

  13. A simple deep monitoring well dilution technique.

    Science.gov (United States)

    Rogiers, Bart; Labat, Serge; Gedeon, Matej; Vandersteen, Katrijn

    2015-04-01

    Well dilution techniques are well known and studied as one of the basic techniques to quantify groundwater fluxes. A typical well dilution test consists of the injection of a tracer, a mixing mechanism (e.g. water circulation with a pump) to achieve a homogeneous concentration distribution within the well, and monitoring of the evolution of tracer concentration with time. An apparent specific discharge can be obtained from such a test, and when details on the well construction are known, it can be converted into a specific discharge representative of the undisturbed aquifer. For deep wells however, the injection of tracer becomes less practical and the use of pumps for circulating and mixing the water becomes problematic. This is due to the limited pressure that common pumps can endure at the outlet, as well as the large volume of water that makes it difficult to achieve a homogeneous concentration, and the impracticalities of getting a lot of equipment to large depths in very small monitoring wells. Injection and monitoring of tracer at a specific depth omits several of the problems with deep wells. We present a very simple device that can be used to perform a dilution test at a specific depth in deep wells. The injection device consists of a PVC tube with a detachable rubber seal at its bottom. To minimize disturbance of the water column in the well, we integrated an EC sensor in this injection device, which enables us to use demineralized water or dissolved salts as a tracer. Once at the target depth, the PVC tube is retracted and the EC sensor and tracer become subject to groundwater flow. The device was tested on a shallow well, on which different types of dilution tests were performed. The results of the other tests agree well with the injection tube results. Finally, the device was used to perform a dilution test in a deep well in order to demonstrate the feasibility of the approach.

  14. Coenzyme F430, quantification and isotope analysis from the Eel River Basin California

    Science.gov (United States)

    Bird, L. R.; Fulton, J. M.; Dawson, K.; Orphan, V. J.; Freeman, K. H.

    2012-12-01

    Large amounts of methane are oxidized by communities of methanotrophic archaea and sulphate-reducing bacteria, preventing this greenhouse gas from reaching the atmosphere (Orphan et al., 2001; Scheller et al., 2010). Methyl-coenzyme M reductase, an enzyme traditionally associated with methanogenesis, has recently been linked to the anaerobic oxidation of methane suggesting methane oxidation follows a pathway similar to reverse methanogenesis. Coenzyme F430, a tetrapyrrole-nickel complex within the active site of methyl-coenzyme M, is used in methanogenesis and is hypothesized to play a key role in archaeal methanotrophy (Scheller et al., 2010). We recently developed a method to extract and isolate F430 from natural sediments so it can be purified for carbon and nitrogen stable isotope analysis. Sediments are extracted using an ultrasonic homogenizer, first in water (pH 7), then twice in dilute formic acid (pH 3). The combined extract is neutralized and the F430-containing fraction is isolated using Sephadex and Amberlite column chromatography. Further purification is performed using two dimensional high performance liquid chromatography, first with a reverse phase C-18 column followed by separation on a ThermoFisher Hypercarb column. F430 is then quantified using photo diode array detection with fractions collected for isotope analysis using a nano-scale elemental analyzer isotope ratio mass spectrometer (nano-EA-IRMS; Polissar et al., 2009). Compound identity and purity are confirmed using molar C:N ratios, UV absorbance and MSn detection of the parent ion (m/z 905). Here, we report F430 concentrations and isotopic data determined from active seep sediment cores from the Eel River Basin (California), a site where the anoxic oxidation of methane occurs. A spike in the concentration of F430 is observed at the 3-6 cm depth horizon corresponding with peak abundance in ANME-2/Desulfosarcina/Desulfococcus aggregate counts. Carbon isotope values of F430 are significantly

  15. Calculation of the transport and relaxation properties of dilute water vapor

    Science.gov (United States)

    Hellmann, Robert; Bich, Eckard; Vogel, Eckhard; Dickinson, Alan S.; Vesovic, Velisa

    2009-07-01

    Transport properties of dilute water vapor have been calculated in the rigid-rotor approximation using four different potential energy hypersurfaces and the classical-trajectory method. Results are reported for shear viscosity, self-diffusion, thermal conductivity, and volume viscosity in the dilute-gas limit for the temperature range of 250-2500 K. Of these four surfaces the CC-pol surface of Bukowski et al. [J. Chem. Phys. 128, 094314 (2008)] is in best accord with the available measurements. Very good agreement is found with the most accurate results for viscosity in the whole temperature range of the experiments. For thermal conductivity the deviations of the calculated values from the experimental data increase systematically with increasing temperature to around 5% at 1100 K. For both self-diffusion and volume viscosity, the much more limited number of available measurements are generally consistent with the calculated values, apart from the lower temperature isotopically labeled diffusion measurements.

  16. Mercury dilution by autochthonous organic matter in a fertilized mangrove wetland.

    Science.gov (United States)

    Machado, Wilson; Sanders, Christian J; Santos, Isaac R; Sanders, Luciana M; Silva-Filho, Emmanoel V; Luiz-Silva, Wanilson

    2016-06-01

    A dated sediment core from a highly-fertilized mangrove wetland located in Cubatão (SE Brazil) presented a negative correlation between mercury (Hg) and organic carbon contents. This is an unusual result for a metal with well-known affinity to organic matter. A dilution of Hg concentrations by autochthonous organic matter explained this observation, as revealed by carbon stable isotopes signatures (δ(13)C). Mercury dilution by the predominant mangrove-derived organic matter counterbalanced the positive influences of algal-derived organic matter and clay contents on Hg levels, suggesting that deleterious effects of Hg may be attenuated. Considering the current paradigm on the positive effect of organic matter on Hg concentrations in coastal sediments and the expected increase in mangrove organic matter burial due to natural and anthropogenic stimulations of primary production, predictions on the influences of organic matter on Hg accumulation in mangrove wetlands deserve caution.

  17. Measurement of phthalates diesters in food using gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Cariou, Ronan; Larvor, Frédéric; Monteau, Fabrice; Marchand, Philippe; Bichon, Emmanuelle; Dervilly-Pinel, Gaud; Antignac, Jean-Philippe; Le Bizec, Bruno

    2016-04-01

    An analytical strategy dedicated to 4 major phthalate diesters (DiBP, DnBP, BBzP and DEHP) monitoring in food items has been developed and validated according to normalized guidelines. The method has been applied to a wide range of foodstuffs (n=54) to generate first-ever occurrence data at the French level. This method involves separation and detection using gas chromatography coupled to tandem mass spectrometry, in electron ionisation with highly specific selected reaction monitoring, quantification being performed according to the isotope dilution principle. A particular attention has been paid to background contamination management at any stage of the analytical process, from the sampling to the expression of the results. Limits of reporting, defined as statistically different from background contamination, were found to be 2.7, 0.53, 0.18 and 3.4 μg kg(-1), and relative combined uncertainties were finally found to be 7.6%, 12.2%, 12.0% and 14.1%, for DiBP, DnBP, BBzP and DEHP, respectively.

  18. Determination of Residual Acrylamide in Medical Polyacrylamide Hydrogel by High Performance Liquid Chromatography tandem Mass Spectroscopy

    Institute of Scientific and Technical Information of China (English)

    WEI-WEI LI; HUI LI; ZHI-FEI LIU; QUN QIAO

    2009-01-01

    Objective To determine residual acrylamide in medical polyacrylamide hydrogel by high performance liquid chromatography tandem mass spectroscopy (HPLC-MS). Methods After 13C3 labeled acrylamide was added, the sample was extracted with water and then cleaned up with ExtrelutTM 20. The polyaerylamide hydrogel sample and 20 clinical cases were analyzed by HPLC-MS/MS and isotope dilution quantifying technique in selected reaction monitoring (SRM) mode. Results Acrylamide was separated from polyacrylamide hydrogel. The concentration of acrylamide in polyacrylamide hydrogel ranged from 3.9×109 to 3.1×108g/L in the 20 clinical cases. The peak area was favorable linear and the range was up to 3 000 μg/L. The recovery rate was 103.1% with a relative standard deviation (RSD) of 6.20%, when the mark level was 50 μg/L. Conclusion HPLC-MS is a rapid, accurate, and sensitive method for the determination of residual acrylamide in medical polyacrylamide hydrogel.

  19. Simultaneous quantification of α-lactalbumin and β-casein in human milk using ultra-performance liquid chromatography with tandem mass spectrometry based on their signature peptides and winged isotope internal standards.

    Science.gov (United States)

    Chen, Qi; Zhang, Jingshun; Ke, Xing; Lai, Shiyun; Li, Duo; Yang, Jinchuan; Mo, Weimin; Ren, Yiping

    2016-09-01

    In recent years, there is an increasing need to measure the concentration of individual proteins in human milk, instead of total human milk proteins. Due to lack of human milk protein standards, there are only few quantification methods established. The objective of the present work was to develop a simple and rapid quantification method for simultaneous determination of α-lactalbumin and β-casein in human milk using signature peptides according to a modified quantitative proteomics strategy. The internal standards containing the signature peptide sequences we