WorldWideScience

Sample records for chemical ionisation mass

  1. Chemical ionisation mass spectrometry: a survey of instrument technology

    International Nuclear Information System (INIS)

    Mather, R.E.; Todd, J.F.J.

    1979-01-01

    The purpose of this review is to survey the innovations and improvements which have been made in both instrumentation and methodology in chemical ionization mass spectrometry in the past ten years. (Auth.)

  2. Chemical profile of mango (Mangifera indica L.) using electrospray ionisation mass spectrometry (ESI-MS).

    Science.gov (United States)

    Oliveira, Bruno G; Costa, Helber B; Ventura, José A; Kondratyuk, Tamara P; Barroso, Maria E S; Correia, Radigya M; Pimentel, Elisângela F; Pinto, Fernanda E; Endringer, Denise C; Romão, Wanderson

    2016-08-01

    Mangifera indica L., mango fruit, is consumed as a dietary supplement with purported health benefits; it is widely used in the food industry. Herein, the chemical profile of the Ubá mango at four distinct maturation stages was evaluated during the process of growth and maturity using negative-ion mode electrospray ionisation Fourier transform ion cyclotron resonance mass spectrometry (ESI(-)FT-ICR MS) and physicochemical characterisation analysis (total titratable acidity (TA), total soluble solids (TSS), TSS/TA ratio, and total polyphenolic content). Primary (organic acids and sugars) and secondary metabolites (polyphenolic compounds) were mostly identified in the third maturation stage, thus indicating the best stage for harvesting and consuming the fruit. In addition, the potential cancer chemoprevention of the secondary metabolites (phenolic extracts obtained from mango samples) was evaluated using the induction of quinone reductase activity, concluding that fruit polyphenols have the potential for cancer chemoprevention. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Eddy covariance flux measurements of ammonia by high temperature chemical ionisation mass spectrometry

    Directory of Open Access Journals (Sweden)

    J. Sintermann

    2011-03-01

    Full Text Available A system for fast ammonia (NH3 measurements with chemical ionisation mass spectrometry (CIMS based on a commercial Proton Transfer Reaction-Mass Spectrometer (PTR-MS is presented. It uses electron transfer reaction as ionisation pathway and features a drift tube of polyetheretherketone (PEEK and silica-coated steel. Heating the instrumental inlet and the drift tube to 180 °C enabled an effective time resolution of ~1 s and made it possible to apply the instrument for eddy covariance (EC measurements. EC fluxes of NH3 were measured over two agricultural fields in Oensingen, Switzerland, following fertilisations with cattle slurry. Air was aspirated close to a sonic anemometer at a flow of 100 STP L min−1 and was directed through a 23 m long 1/2" PFA tube heated to 150 °C to an air-conditioned trailer where the gas was sub-sampled from the large bypass stream. This setup minimised damping of fast NH3 concentration changes between the sampling point and the actual measurement. High-frequency attenuation loss of the NH3 fluxes of 20 to 40% was quantified and corrected for using an empirical ogive method. The instrumental NH3 background signal showed a minor interference with H2O which was characterised in the laboratory. The resulting correction of the NH3 flux after slurry spreading was less than 1‰. The flux detection limit of the EC system was about 5 ng m−2 s−1 while the accuracy of individual flux measurements was estimated 16% for the high-flux regime during these experiments. The NH3 emissions after broad spreading of the slurry showed an initial maximum of 150 μg m−2 s−1 with a fast decline in the following hours.

  4. Deployment of the FIGAERO Iodide Time of flight (ToF)-Chemical ionisation mass spectrometer (CIMS) using X-ray ionisation in Manaus

    Science.gov (United States)

    Bannan, T.; Bacak, A.; Priestley, M.; Adelstein, E.; Worrall, S.; Artaxo, P.; Carbone, S.; Topping, D. O.; Allan, J. D.; Coe, H.; Percival, C.

    2017-12-01

    Here the deployment of the The Filter Inlet for Gases and AEROsols (FIGAERO) coupled with the Aerodyne High Resolution (HR)-Time of flight (ToF)-Chemical ionisation mass spectrometer (CIMS) in Manaus is presented. This project utilised the Tofwerk X-ray ionisation source in the tropical rainforest in close proximity to Manaus, Brazil, at the ZF2 measurement site. The FIGAERO is a filter based technique that provides simultaneous molecular information of both the gas and particle phase. When analysing particles that have been collected the evolution of the MS signals from different compounds change independently as a function of temperature; creating a thermogram that is m/z specific. The temperature for which the desorbed signal shows a maximum for each compound has been used previously to extract vapour pressure information in laboratory characterisatio. Krieger et al. (2017) defined the homologous series of polyethylene glycols as a series of compounds that showed a very good agreement over a wide range of atmospherically relevant vapour pressures between different experimental setups. PEG samples therefore provide an ideal bench mark for characterising individual FIGAERO inlets to give vapour pressure information essential for partitioning characterisation. The PEG calibration curve has been used to validate vapour pressure measurements in a well-defined single component bases and in simple chamber experiments, results of which are presented. With a high reactivity and large ubiquitous global source, isoprene has a profound effect upon atmospheric chemistry and composition. Despite this there are still significant gaps in the understanding of the processes that lead to isoprene derived secondary organic aerosol (SOA). This project aims to provide insights into the role of isoprene in the mechanisms of production of SOA and its importance in the particulate mass budgets in the tropics and the fundamental chemical processes. The volatility and composition of

  5. Airborne hydrogen cyanide measurements using a chemical ionisation mass spectrometer for the plume identification of biomass burning forest fires

    Directory of Open Access Journals (Sweden)

    M. Le Breton

    2013-09-01

    Full Text Available A chemical ionisation mass spectrometer (CIMS was developed for measuring hydrogen cyanide (HCN from biomass burning events in Canada using I− reagent ions on board the FAAM BAe-146 research aircraft during the BORTAS campaign in 2011. The ionisation scheme enabled highly sensitive measurements at 1 Hz frequency through biomass burning plumes in the troposphere. A strong correlation between the HCN, carbon monoxide (CO and acetonitrile (CH3CN was observed, indicating the potential of HCN as a biomass burning (BB marker. A plume was defined as being 6 standard deviations above background for the flights. This method was compared with a number of alternative plume-defining techniques employing CO and CH3CN measurements. The 6-sigma technique produced the highest R2 values for correlations with CO. A normalised excess mixing ratio (NEMR of 3.68 ± 0.149 pptv ppbv−1 was calculated, which is within the range quoted in previous research (Hornbrook et al., 2011. The global tropospheric model STOCHEM-CRI incorporated both the observed ratio and extreme ratios derived from other studies to generate global emission totals of HCN via biomass burning. Using the ratio derived from this work, the emission total for HCN from BB was 0.92 Tg (N yr−1.

  6. Characterisation of chemical components for identifying historical Chinese textile dyes by ultra high performance liquid chromatography – photodiode array – electrospray ionisation mass spectrometer

    NARCIS (Netherlands)

    Han, J.; Wanrooij, J.; van Bommel, M.; Quye, A.

    2017-01-01

    This research makes the first attempt to apply Ultra High Performance Liquid Chromatography (UHPLC) coupled to both Photodiode Array detection (PDA) and Electrospray Ionisation Mass Spectrometer (ESI–MS) to the chemical characterisation of common textile dyes in ancient China. Three different

  7. Characterisation of chemically-modified proteins by electrospray ionisation mass spectrometry

    International Nuclear Information System (INIS)

    Bennett, K.L.

    1996-09-01

    Electrospray mass spectrometry (ESI-MS) has been used to examine a range of intact monoclonal antibodies (MAbs), antibody fragments such as F(ab') 2 , F ab and F c , chemically-modified fragments and a range of other chemically-modified peptides and proteins as part of a broader study aimed at establishing ESI-MS as a method for the characterisation of radioimmunoconjugates (radiolabelled monoclonal antibodies). For example, the addition of up to 10 biotin molecules to the 'papain-sensitive' 50 kDa F ab fragment can be easily detected in ESI mass spectra. For intact MAbs, however, it is only possible to detect average shifts in the mass of intact antibodies following modification. Successful ESI-MS analysis of complexes formed between chelators and other small molecules conjugated to synthetic peptides, hen egg-white Iysozyme (HEL) (M r 14 306) and horse heart myoglobin (M r 16 951) has been demonstrated. ESI-MS offers considerable advantages compared with existing methods for the characterisation of chemically-conjugated proteins including speed and sensitivity of analysis and the capability for obtaining specific structural information. The conditions for ESI-MS of intact MAbs and MAb fragments have been examined in detail and it was found that 150 kDa MAbs generally required lower sample concentration and higher skimmer potentials compared with the 50 kDa F ab fragment and other lower molecular weight proteins. In addition, the m/z range over which ions from MAbs were observed was higher (m/z ∼2000-4500) than for smaller proteins. ESI-MS was also found to be useful for probing the action of the protease papain, that is used to generate MAb fragments (F(ab) '2, F ab and F c ). Further, different sensitivities to papain for different MAb preparations was demonstrated. Finally, the tandem mass spectra of a range of peptides modified by iodine and biotin were examined. In the case of biotinylated peptides, a characteristic fragment ion was identified that could

  8. Rapid analysis of formic acid, acetic acid, and furfural in pretreated wheat straw hydrolysates and ethanol in a bioethanol fermentation using atmospheric pressure chemical ionisation mass spectrometry

    Directory of Open Access Journals (Sweden)

    Smart Katherine A

    2011-09-01

    Full Text Available Abstract Atmospheric pressure chemical ionisation mass spectrometry (APCI-MS offers advantages as a rapid analytical technique for the quantification of three biomass degradation products (acetic acid, formic acid and furfural within pretreated wheat straw hydrolysates and the analysis of ethanol during fermentation. The data we obtained using APCI-MS correlated significantly with high-performance liquid chromatography analysis whilst offering the analyst minimal sample preparation and faster sample throughput.

  9. The potential of organic (electrospray- and atmospheric pressure chemical ionisation) mass spectrometric techniques coupled to liquid-phase separation for speciation analysis.

    Science.gov (United States)

    Rosenberg, Erwin

    2003-06-06

    The use of mass spectrometry based on atmospheric pressure ionisation techniques (atmospheric pressure chemical ionisation, APCI, and electrospray ionisation, ESI) for speciation analysis is reviewed with emphasis on the literature published in and after 1999. This report accounts for the increasing interest that atmospheric pressure ionisation techniques, and in particular ESI, have found in the past years for qualitative and quantitative speciation analysis. In contrast to element-selective detectors, organic mass spectrometric techniques provide information on the intact metal species which can be used for the identification of unknown species (particularly with MS-MS detection) or the confirmation of the actual presence of species in a given sample. Due to the complexity of real samples, it is inevitable in all but the simplest cases to couple atmospheric pressure MS detection to a separation technique. Separation in the liquid phase (capillary electrophoresis or liquid chromatography in reversed phase, ion chromatographic or size-exclusion mode) is particularly suitable since the available techniques cover a very wide range of analyte polarities and molecular mass. Moreover, derivatisation can normally be avoided in liquid-phase separation. Particularly in complex environmental or biological samples, separation in one dimension is not sufficient for obtaining adequate resolution for all relevant species. In this case, multi-dimensional separation, based on orthogonal separation techniques, has proven successful. ESI-MS is also often used in parallel with inductively coupled plasma MS detection. This review is structured in two parts. In the first, the fundamentals of atmospheric pressure ionisation techniques are briefly reviewed. The second part of the review discusses recent applications including redox species, use of ESI-MS for structural elucidation of metal complexes, characterisation and quantification of small organometallic species with relevance to

  10. Acid-yield measurements of the gas-phase ozonolysis of ethene as a function of humidity using Chemical Ionisation Mass Spectrometry (CIMS

    Directory of Open Access Journals (Sweden)

    K. E. Leather

    2012-01-01

    Full Text Available Gas-phase ethene ozonolysis experiments were conducted at room temperature to determine formic acid yields as a function of relative humidity (RH using the integrated EXTreme RAnge chamber-Chemical Ionisation Mass Spectrometry technique, employing a CH3I ionisation scheme. RHs studied were <1, 11, 21, 27, 30 % and formic acid yields of (0.07±0.01 and (0.41±0.07 were determined at <1 % RH and 30 % RH respectively, showing a strong water dependence. It has been possible to estimate the ratio of the rate coefficient for the reaction of the Criegee biradical, CH2OO with water compared with decomposition. This analysis suggests that the rate of reaction with water ranges between 1×10−12–1×10−15 cm3 molecule−1 s−1 and will therefore dominate its loss with respect to bimolecular processes in the atmosphere. Global model integrations suggest that this reaction between CH2OO and water may dominate the production of HC(OOH in the atmosphere.

  11. A new thermal ionisation mass spectrometer

    International Nuclear Information System (INIS)

    Haines, C.; Merren, T.O.; Unsworth, W.D.

    1979-01-01

    The Isomass 54E, a new thermal ionisation mass spectrometer for precise measurements of isotopic composition is described in detail. It combines the fruits of three development pro ects, viz. automation, energy filters and extended geometry with existing micromass expertise and experience. The hardware and software which are used for the automation as well as the energy filter used, are explained. The 'extended geometry' ion optical system adopted for better performance is discussed in detail. (K.B.)

  12. Direct analysis of volatile organic compounds in foods by headspace extraction atmospheric pressure chemical ionisation mass spectrometry.

    Science.gov (United States)

    Perez-Hurtado, P; Palmer, E; Owen, T; Aldcroft, C; Allen, M H; Jones, J; Creaser, C S; Lindley, M R; Turner, M A; Reynolds, J C

    2017-11-30

    The rapid screening of volatile organic compounds (VOCs) by direct analysis has potential applications in the areas of food and flavour science. Currently, the technique of choice for VOC analysis is gas chromatography/mass spectrometry (GC/MS). However, the long chromatographic run times and elaborate sample preparation associated with this technique have led a movement towards direct analysis techniques, such as selected ion flow tube mass spectrometry (SIFT-MS), proton transfer reaction mass spectrometry (PTR-MS) and electronic noses. The work presented here describes the design and construction of a Venturi jet-pump-based modification for a compact mass spectrometer which enables the direct introduction of volatiles for qualitative and quantitative analysis. Volatile organic compounds were extracted from the headspace of heated vials into the atmospheric pressure chemical ionization source of a quadrupole mass spectrometer using a Venturi pump. Samples were analysed directly with no prior sample preparation. Principal component analysis (PCA) was used to differentiate between different classes of samples. The interface is shown to be able to routinely detect problem analytes such as fatty acids and biogenic amines without the requirement of a derivatisation step, and is shown to be able to discriminate between four different varieties of cheese with good intra and inter-day reproducibility using an unsupervised PCA model. Quantitative analysis is demonstrated using indole standards with limits of detection and quantification of 0.395 μg/mL and 1.316 μg/mL, respectively. The described methodology can routinely detect highly reactive analytes such as volatile fatty acids and diamines without the need for a derivatisation step or lengthy chromatographic separations. The capability of the system was demonstrated by discriminating between different varieties of cheese and monitoring the spoilage of meats. © 2017 The Authors. Rapid Communications in Mass

  13. Simultaneous aerosol mass spectrometry and chemical ionisation mass spectrometry measurements during a biomass burning event in the UK: insights into nitrate chemistry

    Directory of Open Access Journals (Sweden)

    E. Reyes-Villegas

    2018-03-01

    Full Text Available Over the past decade, there has been an increasing interest in short-term events that negatively affect air quality such as bonfires and fireworks. High aerosol and gas concentrations generated from public bonfires or fireworks were measured in order to understand the night-time chemical processes and their atmospheric implications. Nitrogen chemistry was observed during Bonfire Night with nitrogen containing compounds in both gas and aerosol phases and further N2O5 and ClNO2 concentrations, which depleted early next morning due to photolysis of NO3 radicals and ceasing production. Particulate organic oxides of nitrogen (PONs concentrations of 2.8 µg m−3 were estimated using the m ∕ z 46 : 30 ratios from aerosol mass spectrometer (AMS measurements, according to previously published methods. Multilinear engine 2 (ME-2 source apportionment was performed to determine organic aerosol (OA concentrations from different sources after modifying the fragmentation table and it was possible to identify two PON factors representing primary (pPON_ME2 and secondary (sPON_ME2 contributions. A slight improvement in the agreement between the source apportionment of the AMS and a collocated AE-31 Aethalometer was observed after modifying the prescribed fragmentation in the AMS organic spectrum (the fragmentation table to determine PON sources, which resulted in an r2 =  0.894 between biomass burning organic aerosol (BBOA and babs_470wb compared to an r2 =  0.861 obtained without the modification. Correlations between OA sources and measurements made using time-of-flight chemical ionisation mass spectrometry with an iodide adduct ion were performed in order to determine possible gas tracers to be used in future ME-2 analyses to constrain solutions. During Bonfire Night, strong correlations (r2 were observed between BBOA and methacrylic acid (0.92, acrylic acid (0.90, nitrous acid (0.86, propionic acid, (0.85 and hydrogen cyanide (0

  14. Simultaneous aerosol mass spectrometry and chemical ionisation mass spectrometry measurements during a biomass burning event in the UK: insights into nitrate chemistry

    Science.gov (United States)

    Reyes-Villegas, Ernesto; Priestley, Michael; Ting, Yu-Chieh; Haslett, Sophie; Bannan, Thomas; Le Breton, Michael; Williams, Paul I.; Bacak, Asan; Flynn, Michael J.; Coe, Hugh; Percival, Carl; Allan, James D.

    2018-03-01

    Over the past decade, there has been an increasing interest in short-term events that negatively affect air quality such as bonfires and fireworks. High aerosol and gas concentrations generated from public bonfires or fireworks were measured in order to understand the night-time chemical processes and their atmospheric implications. Nitrogen chemistry was observed during Bonfire Night with nitrogen containing compounds in both gas and aerosol phases and further N2O5 and ClNO2 concentrations, which depleted early next morning due to photolysis of NO3 radicals and ceasing production. Particulate organic oxides of nitrogen (PONs) concentrations of 2.8 µg m-3 were estimated using the m / z 46 : 30 ratios from aerosol mass spectrometer (AMS) measurements, according to previously published methods. Multilinear engine 2 (ME-2) source apportionment was performed to determine organic aerosol (OA) concentrations from different sources after modifying the fragmentation table and it was possible to identify two PON factors representing primary (pPON_ME2) and secondary (sPON_ME2) contributions. A slight improvement in the agreement between the source apportionment of the AMS and a collocated AE-31 Aethalometer was observed after modifying the prescribed fragmentation in the AMS organic spectrum (the fragmentation table) to determine PON sources, which resulted in an r2 = 0.894 between biomass burning organic aerosol (BBOA) and babs_470wb compared to an r2 = 0.861 obtained without the modification. Correlations between OA sources and measurements made using time-of-flight chemical ionisation mass spectrometry with an iodide adduct ion were performed in order to determine possible gas tracers to be used in future ME-2 analyses to constrain solutions. During Bonfire Night, strong correlations (r2) were observed between BBOA and methacrylic acid (0.92), acrylic acid (0.90), nitrous acid (0.86), propionic acid, (0.85) and hydrogen cyanide (0.76). A series of oxygenated species

  15. Characterisation of bacteria by matrix-assisted laser desorption/ionisation and electrospray mass spectrometry

    NARCIS (Netherlands)

    Baar, B.L.M. van

    2000-01-01

    Chemical analysis for the characterisation of micro-organisms is rapidly evolving, after the recent advent of new ionisation methods in mass spectrometry (MS): electrospray (ES) and matrix-assisted laser desorption/ionisation (MALDI). These methods allow quick characterisation of micro-organisms,

  16. Analysis of wax ester molecular species by high performance liquid chromatography/atmospheric pressure chemical ionisation mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Vrkoslav, Vladimír; Urbanová, Klára; Cvačka, Josef

    2010-01-01

    Roč. 1217, č. 25 (2010), s. 4184-4194 ISSN 0021-9673 R&D Projects: GA ČR GA203/09/0139 Institutional research plan: CEZ:AV0Z40550506 Keywords : Beeswax * Branched esters * Human hair * Jojoba * Mass spectrometry Subject RIV: CC - Organic Chemistry Impact factor: 4.194, year: 2010

  17. Sensitive monitoring of monoterpene metabolites in human urine using two-step derivatisation and positive chemical ionisation-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Schmidt, Lukas; Belov, Vladimir N.; Göen, Thomas

    2013-01-01

    Highlights: •Sensitive monitoring of 10 metabolites of (R)-limonene, α-pinene, and Δ 3 -carene in human urine samples. •Fast and simple sample preparation and derivatisation procedure using two-step silylation for unreactive tertiary hydroxyl groups. •Synthesis of reference substances and isotopically labelled internal standards of (R)-limonene, α-pinene, and Δ 3 -carene metabolites. •Study on (R)-limonene, α-pinene, and Δ 3 -carene metabolite background exposure of 36 occupationally unexposed volunteers. -- Abstract: A gas chromatographic–positive chemical ionisation-tandem mass spectrometric (GC–PCI-MS/MS) method for the simultaneous determination of 10 oxidative metabolites of the monoterpenoid hydrocarbons α-pinene, (R)-limonene, and Δ 3 -carene ((+)-3-carene) in human urine was developed and tested for the monoterpene biomonitoring of the general population (n = 36). The method involves enzymatic cleavage of the glucuronides followed by solid-supported liquid–liquid extraction and derivatisation using a two-step reaction with N,O-bis(trimethylsilyl)-trifluoroacetamide and N-(trimethylsilyl)imidazole. The method proved to be both sensitive and reliable with detection limits ranging from 0.1 to 0.3 μg L −1 . In contrast to the frequent and distinct quantities of (1S,2S,4R)-limonene-1,2-diol, the (1R,2R,4R)-stereoisomer could not be detected. The expected metabolite of (+)-3-carene, 3-caren-10-ol was not detected in any of the samples. All other metabolites were detected in almost all urine samples. The procedure enables for the first time the analysis of trace levels of a broad spectrum of mono- and bicyclic monoterpenoid metabolites (alcohols, diols, and carboxylic acids) in human urine. This analytical procedure is a powerful tool for population studies as well as for the discovery of human metabolism and toxicokinetics of monoterpenes

  18. Determination of N-nitrosamines in processed meats by liquid extraction combined with gas chromatography-methanol chemical ionisation/mass spectrometry.

    Science.gov (United States)

    Scheeren, Marina Bergoli; Sabik, Hassan; Gariépy, Claude; Terra, Nelcindo Nascimento; Arul, Joseph

    2015-01-01

    A simple, accessible and reproducible method was developed and validated as an alternative for the determination of nine volatile N-nitrosamines (NAs) in meat products, using a low volume of organic solvent and without requiring specific apparatus, offering the possibility of practical implementation in routine laboratories. The NAs were extracted with dichloromethane followed by a clean-up with phosphate buffer solution (pH 7.0). The extracts were analysed by gas chromatography-chemical ionisation/mass spectrometry (GC-CI/MS) in positive-ion mode using methanol as reagent. Limits of detection and quantification, recovery and reproducibility were determined for all NAs (N-nitrosodimethylamine, N-nitrosomethylethylamine, N-nitrosodiethylamine, N-nitrosopyrrolidine, N-nitrosodipropylamine, N-nitrosomorpholine, N-nitrosopiperidine, N-nitrosodibutylamine and N-nitrosodiphenylamine). Satisfactory sensitivity and selectivity were obtained even without concentrating the extract by solvent evaporation, avoiding the loss of the nine NAs studied. Limits of detection ranged from 0.15 to 0.37 µg kg(-1), whereas limits of quantification ranged from 0.50 to 1.24 µg kg(-1). Recoveries calculated in cooked ham that had been spiked at 10 and 100 µg kg(-1) were found to be between 70% and 114% with an average relative standard deviation of 13.2%. The method was successfully used to analyse five samples of processed meat products on the day of purchase and 7 days later (after storage at 4°C). The most abundant NAs found in the analysed products were N-nitrosodipropylamine and N-nitrosopiperidine, which ranged from 1.75 to 34.75 µg kg(-1) and from 1.50 to 4.26 µg kg(-1), respectively. In general, an increase in the level of NAs was observed after the storage period. The proposed method may therefore be a useful tool for food safety control once it allows assessing the profile and the dietary intake of NAs in food over time.

  19. Sensitive monitoring of monoterpene metabolites in human urine using two-step derivatisation and positive chemical ionisation-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Lukas [Institute and Outpatient Clinic of Occupational, Social and Environmental Medicine, University of Erlangen-Nuremberg, Schillerstrasse 25/29, 91054 Erlangen (Germany); Belov, Vladimir N. [Max Planck Institute for Biophysical Chemistry, Facility for Synthetic Chemistry, Am Fassberg 11, 37077 Göttingen (Germany); Göen, Thomas, E-mail: Thomas.Goeen@ipasum.med.uni-erlangen.de [Institute and Outpatient Clinic of Occupational, Social and Environmental Medicine, University of Erlangen-Nuremberg, Schillerstrasse 25/29, 91054 Erlangen (Germany)

    2013-09-02

    Highlights: •Sensitive monitoring of 10 metabolites of (R)-limonene, α-pinene, and Δ{sup 3}-carene in human urine samples. •Fast and simple sample preparation and derivatisation procedure using two-step silylation for unreactive tertiary hydroxyl groups. •Synthesis of reference substances and isotopically labelled internal standards of (R)-limonene, α-pinene, and Δ{sup 3}-carene metabolites. •Study on (R)-limonene, α-pinene, and Δ{sup 3}-carene metabolite background exposure of 36 occupationally unexposed volunteers. -- Abstract: A gas chromatographic–positive chemical ionisation-tandem mass spectrometric (GC–PCI-MS/MS) method for the simultaneous determination of 10 oxidative metabolites of the monoterpenoid hydrocarbons α-pinene, (R)-limonene, and Δ{sup 3}-carene ((+)-3-carene) in human urine was developed and tested for the monoterpene biomonitoring of the general population (n = 36). The method involves enzymatic cleavage of the glucuronides followed by solid-supported liquid–liquid extraction and derivatisation using a two-step reaction with N,O-bis(trimethylsilyl)-trifluoroacetamide and N-(trimethylsilyl)imidazole. The method proved to be both sensitive and reliable with detection limits ranging from 0.1 to 0.3 μg L{sup −1}. In contrast to the frequent and distinct quantities of (1S,2S,4R)-limonene-1,2-diol, the (1R,2R,4R)-stereoisomer could not be detected. The expected metabolite of (+)-3-carene, 3-caren-10-ol was not detected in any of the samples. All other metabolites were detected in almost all urine samples. The procedure enables for the first time the analysis of trace levels of a broad spectrum of mono- and bicyclic monoterpenoid metabolites (alcohols, diols, and carboxylic acids) in human urine. This analytical procedure is a powerful tool for population studies as well as for the discovery of human metabolism and toxicokinetics of monoterpenes.

  20. Determination of polar pesticides with atmospheric pressure chemical ionisation mass spectrometry-mass spectrometry using methanol and/or acetonitrile for solid-phase desorption and gradient liquid chromatography.

    NARCIS (Netherlands)

    Geerdink, R.B.; Kooistra-Slijpersma, A.; Tiesnitsch, J.; Kienhuis, P.G.M.; Brinkman, U.A.T.

    1999-01-01

    Thirty-seven polar pesticides, mainly triazines, phenylurea herbicides and phenoxy acids, were determined by LC-atmospheric pressure chemical ionisation MS-MS with methanol and acetonitrile as the organic modifiers. For most pesticides, detection limits were the same irrespective of the modifier.

  1. Bioaerosol detection by aerosol TOF-mass spectrometry: Application of matrix assisted laser desorption/ionisation

    NARCIS (Netherlands)

    Wuijckhuijse, A.L. van; Stowers, M.A.; Kientz, Ch.E.; Marijnissen, J.C.M.; Scarlett, B.

    2000-01-01

    In previous publications the use of an aerosol time of flight mass spectrometer was reported for the on-line measurements of aerosols (Weiss 1997, Kievit 1995). The apparatus is capable of measuring the size as well as the chemical composition, by the use of Laser Desorption/Ionisation (LDI), of an

  2. Thermal ionisation mass spectrometry (TIMS): what, how and why?

    International Nuclear Information System (INIS)

    Aggarwal, S.K.

    2002-01-01

    Thermal ionisation mass spectrometry (TIMS) is one of the oldest mass spectrometric techniques, which has been used for determining the isotopic composition and concentration of different elements using isotope dilution. In spite of the introduction of many other inorganic mass spectrometric techniques like spark source mass spectrometry (SSMS), glow discharge mass spectrometry (GDMS), inductively coupled plasma-mass spectrometry (ICP-MS), secondary ion mass spectrometry (SIMS), the TIMS technique plays the role of a definitive analytical methodology and still occupies a unique position in terms of its capabilities with respect to precision and accuracy as well as sensitivity

  3. Impact ionisation mass spectrometry of polypyrrole-coated pyrrhotite microparticles

    Science.gov (United States)

    Hillier, Jon K.; Sternovsky, Zoltan; Armes, Steven P.; Fielding, Lee A.; Postberg, Frank; Bugiel, Sebastian; Drake, Keith; Srama, Ralf; Kearsley, Anton T.; Trieloff, Mario

    2014-07-01

    Cation and anion impact ionization mass spectra of polypyrrole-coated pyrrhotite cosmic dust analogue particles are analysed over a range of cosmically relevant impact speeds. Spectra with mass resolutions of 150-300 were generated by hypervelocity impacts of charged particles, accelerated to up to 37 km s-1 in a Van de Graaff electrostatic accelerator, onto a silver target plate in the Large Area Mass Analyzer (LAMA) spectrometer. Ions clearly indicative of the polypyrrole overlayer are identified at masses of 93, 105, 117, 128 and 141 u. Organic species, predominantly derived from the thin (20 nm) polypyrrole layer on the surface of the particles, dominate the anion spectra even at high (>20 km s-1) impact velocities and contribute significantly to the cation spectra at velocities lower than this. Atomic species from the pyrrhotite core (Fe and S) are visible in all spectra at impact velocities above 6 km s-1 for 56Fe+, 9 km s-1 for 32S+ and 16 km s-1 for 32S- ions. Species from the pyrrhotite core are also frequently visible in cation spectra at impact speeds at which surface ionisation is believed to dominate (Silver was confirmed as an excellent choice for the target plate of an impact ionization mass spectrometer, as it provided a unique isotope signature for many target-projectile cluster peaks at masses above 107-109 u. The affinity of Ag towards a dominant organic fragment ion (CN-) derived from fragmentation of the polypyrrole component led to molecular cluster formation. This resulted in an enhanced sensitivity to a particular particle component, which may be of great use when investigating astrobiologically relevant chemicals, such as amino acids.

  4. Automation of a thermal ionisation mass spectrometer

    International Nuclear Information System (INIS)

    Pamula, A.; Leuca, M.; Albert, S.; Benta, Adriana

    2001-01-01

    A thermal ionization mass spectrometer was upgraded in order to be monitored by a PC. A PC-LMP-16 National Instruments data acquisition board was used for the ion current channel and the Hall signal channel. A dedicated interface was built to allow commands from the computer to the current supply of the analyzing magnet and to the high voltage unit of the mass spectrometer. A software application was worked out to perform the adjustment of the spectrometer, magnetic scanning and mass spectra acquisition, data processing and isotope ratio determination. The apparatus is used for isotope ratio 235 U/ 238 U determination near the natural abundance. A peak jumping technique is applied to choose between the 235 U and 238 U signal, by switching the high voltage applied to the ion source between two preset values. This avoids the delay between the acquisition of the peaks of interest, a delay that would appear in the case of a 'pure' magnetic scanning. Corrections are applied for the mass discrimination effects and a statistical treatment of the data is achieved. (authors)

  5. Rapid isolation of biomarkers for compound specific radiocarbon dating using high-performance liquid chromatography and flow injection analysis-atmospheric pressure chemical ionisation mass spectrometry

    NARCIS (Netherlands)

    Sinninghe Damsté, J.S.; Smittenberg, R.H.; Hopmans, E.C.; Schouten, S.

    2002-01-01

    Repeated semi-preparative normal-phase HPLC was performed to isolate selected biomarkers from sediment extracts for radiocarbon analysis. Flow injection analysis mass spectrometry was used for rapid analysis of collected fractions to evaluate the separation procedure, taking only 1 min per fraction.

  6. Controllable isotope fractionation with thermal ionisation mass-spectrometers

    International Nuclear Information System (INIS)

    Hebeda, E.H.

    1980-01-01

    Isotopic ratios measured with thermal ionisation mass-spectrometers are biased by fractionation effects. A sample must therefore be analyzed according to the same procedures as applied for the analysis of the standard reference material. A comparison of the behaviour of the sample with that of the standard can then be used as a criterion whether the analytical results are acceptable or not. In this way it is possible to obtain reproducibilities similar to those for elements acceptable or not. In this way it is possible to obtain reproducibilities similar to those for elements where the fractionation can be determined by an internal standard. This procedure of controlled fractionation is demonstrated by means of the 88 Sr/ 86 Sr ratios measured on geological samples and the SRM 987 standard. (orig.)

  7. Chemical analysis of surfaces by resonance ionization mass spectroscopy associated to ionic pulverization; Analyse chimique de surfaces par spectrometrie d`ionisation resonante associee a la pulverisation ionique

    Energy Technology Data Exchange (ETDEWEB)

    Kern, P

    1995-12-19

    This work shows that if resonance ionization mass spectroscopy was first applied in isotopic separation, it`s also an analyzing method adapted to the study of semi-conductor materials and thin foils. We have improved this technic: a neodymium laser coupled with a dye laser, a new argon ions gun, a gallium ions gun and a new collection optic for the secondary ions quadrupole spectrometer to allow quantitative and selective measurements. (S.G.). 84 refs.

  8. Rapid isolation of biomarkers for compound specific radiocarbon dating using high-performance liquid chromatography and flow injection analysis-atmospheric pressure chemical ionisation mass spectrometry.

    Science.gov (United States)

    Smittenberg, Rienk H; Hopmans, Ellen C; Schouten, Stefan; Sinninghe Damsté, Jaap S

    2002-11-29

    Repeated semi-preparative normal-phase HPLC was performed to isolate selected biomarkers from sediment extracts for radiocarbon analysis. Flow injection analysis-mass spectrometry was used for rapid analysis of collected fractions to evaluate the separation procedure, taking only 1 min per fraction. In this way 100-1000 microg of glycerol dialkyl glycerol tetraethers, sterol fractions and chlorophyll-derived phytol were isolated from typically 100 g of marine sediment, i.e., in sufficient quantities for radiocarbon analysis, without significant carbon isotopic fractionation or contamination.

  9. Atmospheric pressure chemical ionisation mass spectrometry analysis linked with chemometrics for food classification - a case study: geographical provenance and cultivar classification of monovarietal clarified apple juices.

    Science.gov (United States)

    Gan, Heng-Hui; Soukoulis, Christos; Fisk, Ian

    2014-03-01

    In the present work, we have evaluated for first time the feasibility of APCI-MS volatile compound fingerprinting in conjunction with chemometrics (PLS-DA) as a new strategy for rapid and non-destructive food classification. For this purpose 202 clarified monovarietal juices extracted from apples differing in their botanical and geographical origin were used for evaluation of the performance of APCI-MS as a classification tool. For an independent test set PLS-DA analyses of pre-treated spectral data gave 100% and 94.2% correct classification rate for the classification by cultivar and geographical origin, respectively. Moreover, PLS-DA analysis of APCI-MS in conjunction with GC-MS data revealed that masses within the spectral ACPI-MS data set were related with parent ions or fragments of alkyesters, carbonyl compounds (hexanal, trans-2-hexenal) and alcohols (1-hexanol, 1-butanol, cis-3-hexenol) and had significant discriminating power both in terms of cultivar and geographical origin. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Single-stage accelerator mass spectrometer radiocarbon-interference identification and positive-ionisation characterisation

    Energy Technology Data Exchange (ETDEWEB)

    Wilcken, K.M., E-mail: klaus.wilcken@ansto.gov.au [Scottish Universities Environmental Research Centre, Scottish Enterprise Technology Park, East Kilbride G75 0QF (United Kingdom); Freeman, S.P.H.T.; Xu, S.; Dougans, A. [Scottish Universities Environmental Research Centre, Scottish Enterprise Technology Park, East Kilbride G75 0QF (United Kingdom)

    2013-01-15

    A single-stage accelerator mass spectrometer (SSAMS) is a good alternative to conventional spectrometers based on tandem electrostatic acceleration for radiocarbon measurement and permits experimentation with both negative and positive carbon ions. However, such {sup 14}C AMS of either polarity ions is limited by an interference. In the case of anion acceleration we have newly determined this to be summed {sup 13}C and {sup 16}O by improvising an additional Wien filter on our SSAMS deck. Also, {sup 14}C AMS might be improved by removing its dependency on negative-ionisation in a sputter ion source. This requires negative-ionisation of sample atoms elsewhere to suppress the {sup 14}N interference, which we accomplish by transmitting initially positive ions through a thin membrane. The ionisation dependence on ion-energy is found to be consistent with previous experimentation with vapours and thicker foils.

  11. Chemically modified carbon nanotubes as material enhanced laser desorption ionisation (MELDI) material in protein profiling

    International Nuclear Information System (INIS)

    Najam-ul-Haq, M.; Rainer, M.; Schwarzenauer, T.; Huck, C.W.; Bonn, G.K.

    2006-01-01

    Biomarkers play a potential role in the early detection and diagnosis of a disease. Our aim is to derivatize carbon nanotubes for exploration of the differences in human body fluids e.g. serum, through matrix assisted laser desorption ionisation/time of flight mass spectrometry (MALDI/TOF-MS) that can be related to disease and subsequently to be employed in the biomarker discovery process. This application we termed as the material enhanced laser desorption ionisation (MELDI). The versatility of this technology is meant to increase the amount of information from biological samples on the protein level, which will have a major impact to serve the cause of diagnostic markers. Serum peptides and proteins are immobilized on derivatized carbon nanotubes, which function as binding material. Protein-loaded suspension is placed on a stainless steel target or buckypaper on aluminum target for direct analysis with MALDI-MS. The elution method to wash the bound proteins from carbon nanotubes was employed to compare with the direct analysis procedure. Elution is carried out by MALDI matrix solution to get them out of the entangled nanotubes, which are difficult to desorb by laser due to the complex nanotube structures. The advantage of these optimized methods compared to the conventional screening methods is the improved sensitivity, selectivity and the short analysis time without prior albumin and immunoglobulin depletion. The comparison of similarly modified diamond and carbon nanotubes exhibit differences in their nature to bind the proteins out of serum due to the differences in their physical characteristics. Infrared (IR) spectroscopy provided hint for the presence of tertiary amine peak at the crucial chemical step of iminodiacetic acid addition to acid chloride functionality on carbon nanotubes. Atomic absorption spectroscopy (AAS) was utilized to quantitatively measure the copper capacity of these derivatized carbon nanotubes which is a direct measure of capacity of

  12. Application of positive mode atmospheric chemical ionisation to distinguish epimeric oleanolic and ursolic acids.

    Science.gov (United States)

    Townley, Chloe; Brettell, Rhea C; Bowen, Richard D; Gallagher, Richard T; Martin, William H C

    2015-01-01

    A new and more reliable method is reported for distinguishing the equatorial and axial epimers of oleanolic and ursolic acids and related triterpenoids based primarily on the relative abundance of the [M+H](+) and [M+-H(2)O](+) signals in their positive mode atmospheric pressure chemical ionisation mass spectra. The rate of elimination of water, which is the principal primary fragmentation of protonated oleanolic and ursolic acids, depends systematically on the stereochemistry of the hydroxyl group in the 3 position. For the b-epimer, in which the 3-hydroxyl substituent is in an equatorial position,[M+-H(2)O](+) is the base peak. In contrast, for the α-epimer, where the 3-hydroxyl group is axial, [M + H](+) is the base peak. This trend, which is general for a range of derivatives of oleanolic and ursolic acids, including the corresponding methyl esters, allows epimeric triterpenoids in these series to be securely differentiated. Confirmatory information is available from the collision-induced dissociation of the [M+-H(2)O](+) primary fragment ions, which follow different pathways for the species derived from axial and equatorial epimers of oleanolic and ursolic acids. These two pieces of independent spectral information permit the stereochemistry of epimeric oleanolic and ursolic acids (and selected derivatives) to be assigned with confidence without relying either on chromatographic retention times or referring to the spectra or other properties of authentic samples of these triterpenoids.

  13. Thermal ionisation mass spectrometry: recent developments and future prospects

    International Nuclear Information System (INIS)

    Aggarwal, S.K.

    1996-01-01

    This paper presents the current state of art of thermal ionization mass spectrometry (TIMS) instrumentation and highlights some of the recent applications of TIMS in geological, biological and nuclear sciences with special emphasis on some of the recent work undertaken in the area of nuclear science and technology. A few examples from the published literature are also discussed here

  14. Analysis of oak tannins by liquid chromatography-electrospray ionisation mass spectrometry.

    Science.gov (United States)

    Mämmelä, P; Savolainen, H; Lindroos, L; Kangas, J; Vartiainen, T

    2000-09-01

    Extractable tannins were analysed by liquid chromatography-electrospray ionisation mass spectrometry in two oak species, North American white oak (Quercus alba) and European red oak (Quercus robur). They mainly included various glucose gallic and ellagic acid esters. The structures were partially determined, and they included grandinin/roburin E, castalagin/vescalagin, gallic acid, valoneic acid bilactone, monogalloyl glucose, digalloyl glucose, trigalloyl glucose, ellagic acid rhamnose, quercitrin and ellagic acid.

  15. U-series dating using thermal ionisation mass spectrometry (TIMS)

    International Nuclear Information System (INIS)

    McCulloch, M.T.

    1999-01-01

    U-series dating is based on the decay of the two long-lived isotopes 238 U(τ 1/2 =4.47 x 10 9 years) and 235 U (τ 1/2 0.7 x 10 9 years). 238 U and its intermediate daughter isotopes 234 U (τ 1/2 = 245.4 ka) and 230 Th (τ 1/2 = 75.4 ka) have been the main focus of recently developed mass spectrometric techniques (Edwards et al., 1987) while the other less frequently used decay chain is based on the decay 235 U to 231 Pa (τ 1/2 = 32.8 ka). Both the 238 U and 235 U decay chains terminate at the stable isotopes 206 Pb and 207 Pb respectively. Thermal ionization mass spectrometry (TIMS) has a number of inherent advantages, mainly the ability to measure isotopic ratios at high precision on relatively small samples. In spite of these now obvious advantages, it is only since the mid-1980's when Chen et al., (1986) made the first precise measurements of 234 U and 232 Th in seawater followed by Edwards et al., (1987) who made combined 234 U- 230 Th measurements, was the full potential of mass spectrometric methods first realised. Several examples are given to illustrate various aspects of TIMS U-series

  16. Comparison of quantification methods for the analysis of polychlorinated alkanes using electron capture negative ionisation mass spectrometry

    NARCIS (Netherlands)

    Rusina, T.; Korytar, P.; Boer, de J.

    2011-01-01

    Four quantification methods for short-chain chlorinated paraffins (SCCPs) or polychlorinated alkanes (PCAs) using gas chromatography electron capture negative ionisation low resolution mass spectrometry (GC-ECNI-LRMS) were investigated. The method based on visual comparison of congener group

  17. U-series dating using thermal ionisation mass spectrometry (TIMS)

    Energy Technology Data Exchange (ETDEWEB)

    McCulloch, M.T. [Australian National University, Canberra, ACT (Australia). Research School of Earth Science

    1999-11-01

    U-series dating is based on the decay of the two long-lived isotopes{sup 238}U({tau}{sub 1/2}=4.47 x 10{sup 9} years) and {sup 235}U ({tau}{sub 1/2} 0.7 x 10{sup 9} years). {sup 238}U and its intermediate daughter isotopes {sup 234}U ({tau}{sub 1/2} = 245.4 ka) and {sup 230}Th ({tau}{sub 1/2} = 75.4 ka) have been the main focus of recently developed mass spectrometric techniques (Edwards et al., 1987) while the other less frequently used decay chain is based on the decay {sup 235}U to {sup 231}Pa ({tau}{sub 1/2} = 32.8 ka). Both the {sup 238}U and {sup 235}U decay chains terminate at the stable isotopes {sup 206}Pb and {sup 207}Pb respectively. Thermal ionization mass spectrometry (TIMS) has a number of inherent advantages, mainly the ability to measure isotopic ratios at high precision on relatively small samples. In spite of these now obvious advantages, it is only since the mid-1980`s when Chen et al., (1986) made the first precise measurements of {sup 234}U and {sup 232}Th in seawater followed by Edwards et al., (1987) who made combined {sup 234}U-{sup 230}Th measurements, was the full potential of mass spectrometric methods first realised. Several examples are given to illustrate various aspects of TIMS U-series 9 refs., 3 figs.

  18. Hyphenation of ultra high performance supercritical fluid chromatography with atmospheric pressure chemical ionisation high resolution mass spectrometry: Part 1. Study of the coupling parameters for the analysis of natural non-polar compounds.

    Science.gov (United States)

    Duval, Johanna; Colas, Cyril; Pecher, Virginie; Poujol, Marion; Tranchant, Jean-François; Lesellier, Eric

    2017-08-04

    An analytical method based on Ultra-High-Performance Supercritical Fluid Chromatography (UHPSFC) coupled with Atmospheric Pressure Chemical Ionization - High-resolution mass spectrometry (APCI-Q-TOF-HRMS) was developed for compounds screening from oily samples. The hyphenation was made using a commercial UHPLC device coupled to a CO 2 pump in order to perform the chromatographic analysis. An adaptation of the injection system for compressible fluids was accomplished for this coupling: this modification of the injection sequence was achieved to prevent unusual variations of the injected volume related to the use of a compressible fluid. UHPSFC-HRMS hyphenation was optimized to enhance the response of the varied compounds from a seed extract (anthraquinones, free fatty acids, diacylglycerols, hydroxylated triacylglycerols and triacylglycerols). No split was used prior to the APCI ionization source, allowing introducing all the compounds in the spectrometer, ensuring a better sensitivity for minor compounds. The effects of a mechanical make-up (T-piece) added before this ionization source was discussed in terms of standard deviation of response, response intensity and fragmentation percentage. The location of the T-piece with regards to the backpressure regulator (BPR), the flow rate and the nature of the make-up solvent were studied. Results show that the effects of the studied parameters depend on the nature of the compounds, whereas the make-up addition favours the robustness of the mass response (quantitative aspect). Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Metabolite signal identification in accurate mass metabolomics data with MZedDB, an interactive m/z annotation tool utilising predicted ionisation behaviour 'rules'

    Directory of Open Access Journals (Sweden)

    Snowdon Stuart

    2009-07-01

    Full Text Available Abstract Background Metabolomics experiments using Mass Spectrometry (MS technology measure the mass to charge ratio (m/z and intensity of ionised molecules in crude extracts of complex biological samples to generate high dimensional metabolite 'fingerprint' or metabolite 'profile' data. High resolution MS instruments perform routinely with a mass accuracy of Results Metabolite 'structures' harvested from publicly accessible databases were converted into a common format to generate a comprehensive archive in MZedDB. 'Rules' were derived from chemical information that allowed MZedDB to generate a list of adducts and neutral loss fragments putatively able to form for each structure and calculate, on the fly, the exact molecular weight of every potential ionisation product to provide targets for annotation searches based on accurate mass. We demonstrate that data matrices representing populations of ionisation products generated from different biological matrices contain a large proportion (sometimes > 50% of molecular isotopes, salt adducts and neutral loss fragments. Correlation analysis of ESI-MS data features confirmed the predicted relationships of m/z signals. An integrated isotope enumerator in MZedDB allowed verification of exact isotopic pattern distributions to corroborate experimental data. Conclusion We conclude that although ultra-high accurate mass instruments provide major insight into the chemical diversity of biological extracts, the facile annotation of a large proportion of signals is not possible by simple, automated query of current databases using computed molecular formulae. Parameterising MZedDB to take into account predicted ionisation behaviour and the biological source of any sample improves greatly both the frequency and accuracy of potential annotation 'hits' in ESI-MS data.

  20. Peroxyacetyl nitrate (PAN and peroxyacetic acid (PAA measurements by iodide chemical ionisation mass spectrometry: first analysis of results in the boreal forest and implications for the measurement of PAN fluxes

    Directory of Open Access Journals (Sweden)

    G. J. Phillips

    2013-02-01

    Full Text Available We describe measurements of peroxyacetyl nitrate (CH3C(OO2NO2, PAN and peroxyacetic acid (CH3C(OOOH, PAA in the Boreal forest using iodide chemical ionization mass spectrometry (ICIMS. The measurements were made during the Hyytiälä United Measurement of Photochemistry and Particles – Comprehensive Organic Particle and Environmental Chemistry (HUMPPA-COPEC-2010 measurement intensive. Mixing ratios of PAN and PAA were determined by measuring the acetate ion signal (CH3C(OO, m/z = 59 resulting from reaction of CH3C(OO2 (from the thermal dissociation of PAN or CH3C(OOOH with iodide ions using alternatively heated and ambient temperature inlet lines. During some periods of high temperature (~ 30 °C and low NOx (< 1 ppbv, PAA mixing ratios were similar to, or exceeded those of PAN and thus contributed a significant fraction of the total acetate signal. PAA is thus a potential interference for ICIMS measurements of PAN, and especially eddy covariance flux measurements in environments where the PAA flux is likely to be a significant proportion of the (short timescale acetate ion variability. Within the range of mixing ratios of NOx measured during HUMPPA-COPEC, the modelled ratio of PAA-to-PAN was found to be sensitive to temperature (through the thermal decomposition rate of PAN and the HO2 mixing ratio, thus providing some constraint to estimates of photochemical activity and oxidation rates in the Boreal environment.

  1. Isotope Dilution - Thermal Ionisation Mass Spectrometric Analysis for Tin in a Fly Ash Material

    International Nuclear Information System (INIS)

    Hernandez, C.; Fernandez, M.; Quejido, A. L.

    2006-01-01

    Isotope dilution-thermal ionisation mass spectrometry (ID-TIMS) analysis has been applied to the determination of tin in a fly ash sample supplied by the EC Joint Research Centre (Ispra, Italy). The proposed procedure includes the silica gel/phosphoric acid technique for tin thermal ionisation activation and a strict heating protocol for isotope ratio measurements. Instrumental mass discrimination factor has been previously determined measuring a natural tin standard solution. Spike solutions has been prepared from 112Sn-enriched metal and quantified by reverse isotope dilution analysis. Two sample aliquots were spiked and tin was extracted with 4,5 M HCI during 25 min ultrasound esposure time. Due to the complex matrix of this fly ash material, a two-steps purification stage using ion-exchange chromatography was required prior TIMS analysis. Obtained results for the two sample-spike blends (10,10 + - 0,55 y 10,50 + - 0,64 imolg-1) are comprarable, both value and uncertainty. Also a good reproducibility is observed between measurements. The proposed ID-TIMS procedure, as a primary method and due to the lack of fly ash reference material certified for tin content, can be used to validate more routine methodologies applied to tin determination in this kind of materials. (Author) 75 refs

  2. STRAPS v1.0: evaluating a methodology for predicting electron impact ionisation mass spectra for the aerosol mass spectrometer

    Directory of Open Access Journals (Sweden)

    D. O. Topping

    2017-06-01

    Full Text Available Our ability to model the chemical and thermodynamic processes that lead to secondary organic aerosol (SOA formation is thought to be hampered by the complexity of the system. While there are fundamental models now available that can simulate the tens of thousands of reactions thought to take place, validation against experiments is highly challenging. Techniques capable of identifying individual molecules such as chromatography are generally only capable of quantifying a subset of the material present, making it unsuitable for a carbon budget analysis. Integrative analytical methods such as the Aerosol Mass Spectrometer (AMS are capable of quantifying all mass, but because of their inability to isolate individual molecules, comparisons have been limited to simple data products such as total organic mass and the O : C ratio. More detailed comparisons could be made if more of the mass spectral information could be used, but because a discrete inversion of AMS data is not possible, this activity requires a system of predicting mass spectra based on molecular composition. In this proof-of-concept study, the ability to train supervised methods to predict electron impact ionisation (EI mass spectra for the AMS is evaluated. Supervised Training Regression for the Arbitrary Prediction of Spectra (STRAPS is not built from first principles. A methodology is constructed whereby the presence of specific mass-to-charge ratio (m∕z channels is fitted as a function of molecular structure before the relative peak height for each channel is similarly fitted using a range of regression methods. The widely used AMS mass spectral database is used as a basis for this, using unit mass resolution spectra of laboratory standards. Key to the fitting process is choice of structural information, or molecular fingerprint. Our approach relies on using supervised methods to automatically optimise the relationship between spectral characteristics and these molecular

  3. STRAPS v1.0: evaluating a methodology for predicting electron impact ionisation mass spectra for the aerosol mass spectrometer

    Science.gov (United States)

    Topping, David O.; Allan, James; Rami Alfarra, M.; Aumont, Bernard

    2017-06-01

    Our ability to model the chemical and thermodynamic processes that lead to secondary organic aerosol (SOA) formation is thought to be hampered by the complexity of the system. While there are fundamental models now available that can simulate the tens of thousands of reactions thought to take place, validation against experiments is highly challenging. Techniques capable of identifying individual molecules such as chromatography are generally only capable of quantifying a subset of the material present, making it unsuitable for a carbon budget analysis. Integrative analytical methods such as the Aerosol Mass Spectrometer (AMS) are capable of quantifying all mass, but because of their inability to isolate individual molecules, comparisons have been limited to simple data products such as total organic mass and the O : C ratio. More detailed comparisons could be made if more of the mass spectral information could be used, but because a discrete inversion of AMS data is not possible, this activity requires a system of predicting mass spectra based on molecular composition. In this proof-of-concept study, the ability to train supervised methods to predict electron impact ionisation (EI) mass spectra for the AMS is evaluated. Supervised Training Regression for the Arbitrary Prediction of Spectra (STRAPS) is not built from first principles. A methodology is constructed whereby the presence of specific mass-to-charge ratio (m/z) channels is fitted as a function of molecular structure before the relative peak height for each channel is similarly fitted using a range of regression methods. The widely used AMS mass spectral database is used as a basis for this, using unit mass resolution spectra of laboratory standards. Key to the fitting process is choice of structural information, or molecular fingerprint. Our approach relies on using supervised methods to automatically optimise the relationship between spectral characteristics and these molecular fingerprints. Therefore

  4. Burn-up determination of irradiated thoria samples by isotope dilution-thermal ionisation mass spectrometry

    International Nuclear Information System (INIS)

    Aggarwal, S.K.; Jaison, P.G.; Telmore, V.M.; Shah, R.V.; Sant, V.L.; Sasibhushan, K.; Parab, A.R.; Alamelu, D.

    2010-03-01

    Burn-up was determined experimentally using thermal ionization mass spectrometry for two samples from ThO 2 bundles irradiated in KAPS-2. This involved quantitative dissolution of the irradiated fuel samples followed by separation and determination of Th, U and a stable fission product burn-up monitor in the dissolved fuel solution. Stable fission product 148 Nd was used as a burn-up monitor for determining the number of fissions. Isotope Dilution-Thermal Ionisation Mass Spectrometry (ID-TIMS) using natural U, 229 Th and enriched 142 Nd as spikes was employed for the determination of U, Th and Nd, respectively. Atom % fission values of 1.25 ± 0.03 were obtained for both the samples. 232 U content in 233 U determined by alpha spectrometry was about 500 ppm and this was higher by a factor of 5 compared to the theoretically predicted value by ORIGEN-2 code. (author)

  5. Desorption electrospray ionisation mass spectrometry: A rapid screening tool for veterinary drug preparations and forensic samples from hormone crime investigations

    NARCIS (Netherlands)

    Nielen, M.W.F.; Hooijerink, H.; Claassen, F.C.; Engelen, M.C.; Beek, van T.A.

    2009-01-01

    Hormone and veterinary drug screening and forensics can benefit from the recent developments in desorption electrospray ionisation (DESI) mass spectrometry (MS). In this work the feasibility of DESI application has been studied. Using a linear ion trap or quadrupole time-of-flight (TOF) MS

  6. Determination of fluspirilene in human plasma by liquid chromatography-tandem mass spectrometry with electrospray ionisation.

    Science.gov (United States)

    Swart, K J; Sutherland, F C; van Essen, G H; Hundt, H K; Hundt, A F

    1998-12-18

    An ultra-sensitive method for the determination of fluspirilene in plasma was established, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The samples were extracted with hexane/isoamyl alcohol, separated on a Phenomenex Luna C18 5 mu 150 x 2.1 mm column with a mobile phase consisting of methanol-water-acetic acid (600:400:1) at a flow-rate of 0.3 ml/min. Detection was achieved by a Finnigan Matt mass spectrometer (LCQ) at unit resolution in full scan mode scanning the product ion spectrum from m/z 130-500 and monitoring the transition of the protonated molecular ion at m/z 476.2, to the sum of the largest product ions m/z 371, 342 and 274 (MS-MS). Electrospray ionisation was used for ion production. The mean recovery for fluspirilene was 90% with a lower limit of quantification of 21.50 pg/ml using 1 ml plasma for extraction. This is the first chromatographic method described for the determination of fluspirilene in plasma that is accurate and sensitive enough to be used in pharmacokinetic studies.

  7. Performance characteristics of a Bioassay method for plutonium using thermal ionisation mass spectrometry (TIMS)

    Energy Technology Data Exchange (ETDEWEB)

    Linauskas, S.H.; Elliot, N.L.; Paterson, L.M.; Totland, M.M

    2003-01-01

    Plutonium-in-urine analysis by radiochemical isolation of Pu followed by thermal ionisation mass spectrometry (TIMS) is capable of high sensitivity and precision measurements {sup 239}Pu and {sup 240}Pu. Bias and precision estimates for the TIMS bioassay program at Chalk River Laboratories easily met the ANSI N13.30 performance criteria standards with {sup 239}Pu results of 1.5% and 3.0%, respectively. Analytical blanks derived from water, artificial urine and true urine samples did not produce any statistically different results. During a four-year period of development and implementation of {sup 239}Pu measurements by TIMS, average sample blank values were reduced from 3.9 fg (9.0 {mu}Bq) to 0.57 fg (1.3 {mu}Bq). This reduction was achieved through rigorous application of clean-room handling techniques throughout sample processing. Blank data were found to follow a Iognormal distribution, and current detection limit parameters for L{sub c} and L{sub d} at the 95% significance levels are 0.85 fg {sup 239}Pu (2.0 {mu}Bq) and 1.3 fg {sup 239}Pu (3.0 {mu}Bq), respectively. Detection limits in this range are expected to be sufficient to identify intakes of Pu/Am mixtures at levels that are around one-twentieth of an ALl or better under routine monitoring situations for ICRP Type S and Type M inhalation solubility classes. (author)

  8. Characterisation of tryptic peptides of phosphorylated tyrosine hydroxylase by high-pressure liquid chromatography electrospray ionisation mass spectrometry

    International Nuclear Information System (INIS)

    Graham, Mark E.; Dickson, Phillip W.; Dunkley, Peter R.; Nagy-Felsobuki, Ellak I. von

    2005-01-01

    Tyrosine hydroxylase (TH) is involved in the biosynthesis of catecholamines and is activated by phosphorylation. Phosphorylated TH was analysed using high-pressure liquid chromatography combined with electrospray mass spectrometry (HPLC ESI-MS). Two mass scanning methods were used to detect tryptic cleavage products of TH. In the positive electrospray ionisation mode (ESI+), the peptides that contain the phosphorylation sites of TH were identified. In the alternative method, a phosphopeptide was detected in the negative electrospray ionisation mode (ESI-) using single ion monitoring in combination with a sequential ESI+ switching experiment. A raised baseline interfered with detection of hydrophilic peptides in ESI-, with the signal-to-noise ratio indicating that the method was operating near the limit of detection for a conventional electrospray source. The switching method improved the certainty of identification of phosphopeptides

  9. Measurement of small ion beams by thermal ionisation mass spectrometry using new 1013 Ohm resistors

    International Nuclear Information System (INIS)

    Koornneef, J.M.; Bouman, C.; Schwieters, J.B.; Davies, G.R.

    2014-01-01

    Highlights: • First data are presented using 10 13 Ohm resistors connected to Faraday collectors. • 5 prototype 10 13 Ohm resistors were installed in a TRITON-Plus TIMS. • Performance was tested by measuring Sr and Nd isotope ratios on  13 Ohm resistors perform better than ion counting and 10 11 Ohm resistors. • Fourth decimal variability can be resolved for Nd isotope ratios on 10 pg samples. - Abstract: We tested 5 newly manufactured – prototype – 10 13 Ohm resistors in the feedback loop of Faraday cup amplifiers to measure small ion beams by Thermal Ionisation Mass Spectrometry (TIMS). The high Ohmic resistors installed in the TRITON Plus at the VU University Amsterdam theoretically have 10 times lower noise levels relative to the default 10 11 Ohm resistors. To investigate the precision and accuracy of analyses using these new amplifiers we measured Sr and Nd isotopes of reference standards at a range of ion currents (3.2 × 10 −16 to 1 × 10 −12 A, corresponding to intensities of 32 μV to 100 mV on a default 10 11 Ohm amplifier) and on small amounts of material (100 and 10 pg). Internal precision and external reproducibility for Sr and Nd isotope ratios are both better when collected on 10 13 compared 10 12 Ohm resistors and to the default 10 11 Ohm resistors. At an 87 Sr ion current of 3 × 10 −14 A (3 mV on a 10 11 Ohm amplifier) the internal precision (2 SE) of 87 Sr/ 86 Sr is 5 times better for 10 13 Ohm resistors compared to 10 11 Ohm resistors. The external reproducibility (2 SD) at this beam intensity is 9 times better. Multiple 100 and 10 pg Sr standards, ran to exhaustion, yielded low 87 Sr/ 86 Sr compared to the long term average (e.g. 10 pg average = 0.710083 ± 164 (n = 11) instead of 0.710244 ± 12, n = 73). The average off-set for 10 pg standards can be explained by a loading blank contribution of 1.3 pg. In contrast, Nd data on 100 pg and 10 pg samples are accurate suggesting that Nd loading blanks do not compromise the

  10. Current status of matrix-assisted laser desorption ionisation-time of flight mass spectrometry in the clinical microbiology laboratory.

    Science.gov (United States)

    Kok, Jen; Chen, Sharon C A; Dwyer, Dominic E; Iredell, Jonathan R

    2013-01-01

    The integration of matrix-assisted laser desorption ionisation-time of flight mass spectrometry (MALDI-TOF MS) into many clinical microbiology laboratories has revolutionised routine pathogen identification. MALDI-TOF MS complements and has good potential to replace existing phenotypic identification methods. Results are available in a more clinically relevant timeframe, particularly in bacteraemic septic shock. Novel applications include strain typing and the detection of antimicrobial resistance, but these are not widely used. This review discusses the technical aspects, current applications, and limitations of MALDI-TOF MS.

  11. Use of the Isomass 54E thermal ionisation mass spectrometer at AEE Winfrith. Part II: plutonium analysis

    International Nuclear Information System (INIS)

    Knight, A.P.

    1982-06-01

    This report describes the application of the Isomass 54E Thermal ionisation mass spectrometer for the isotopic analysis of plutonium, and gives details of the development of a method for quantitative determination of plutonium in sample solutions using isotopic dilution. A computer program for the control of the 54E is also described. Isotope dilution was used to compare results of plutonium content of twelve zebra reactor fuel pellets with results obtained by titrimetry. The Isomass 54E is shown to be capable of high precision analysis of plutonium sample solutions for both isotopic content and total plutonium concentration using an isotope dilution technique. (U.K.)

  12. Double spike methodology for uranium determination by thermal ionisation mass spectrometry: separation and purification of 234U

    International Nuclear Information System (INIS)

    Shah, P.M.; Saxena, M.K.; Sanjai Kumar; Aggarwal, S.K.; Jain, H.C.

    1995-01-01

    With an objective to prepare double spike of 233 U+ 234 U for determination of uranium concentration by Isotopic Dilution Thermal Ionisation Mass Spectrometry (ID-TIMS), 234 U was separated and purified from aged 238 Pu sample (15 years old) using several ion exchange and solvent extraction procedures. Final product containing 95% and 5% alpha activities of 234 and 238 Pu, respectively, which translates into 99.998 atom% of 234 U and 0.002 atom% of 238 Pu was found suitable for double spike. (author). 1 ref

  13. 226Ra measurement by thermal ionisation mass spectrometry: Use of 226Ra and 14C for groundwater dating

    International Nuclear Information System (INIS)

    Dever, L.

    1997-01-01

    Recent developments in thermal ionisation mass spectrometry (TIMS) and in chemical separation Ra and Ba allow to analyse 226 Ra on smaller water samples ( 3 litres). The sampling has been realised on the Chalk aquifer of the Paris basin. The water samples have been collected in the unsaturated zone using in situ filtering devices and in the unconfined and confined parts of the aquifer in the boreholes used for public water supply. 226 Ra contents vary from 0.064±0.02 dpm/kg (n=6) in the unsaturated zone to 0.119±0.069 dpm/kg (n=7) in the unconfined aquifer and 0.319±0.057 dpm/kg (n=9) in the confined aquifer. For all the samples the 226 Ra/ 238 U activity ratios are much lower than the secular equilibrium. This points out that the two isotopes have different input function in the water during the mineralisation of the solution. The good correlation (r 2 =0.9) between the 226 Ra and Sr indicates that dissolution of Chalk is the dominant mechanism of mineralisation in 226 Ra of the solution. In the Chalk the mineralisation of the water occurs in the first metres of the unsaturated zone, during the water percolation the water rock interaction takes place through dissolution and precipitation of calcite in a non steady state. According to his distribution coefficient Sr is then a better tracer of dissolution/precipitation process than Ba. Using a geochemical model based on 226 Ra/Sr and Sr/Ca ratios an 'age' of the water could be determined. With 226 Ra half life of 1620 years we obtain 'ages' varying from 150 years to 1950 years in the unconfined aquifer. For the confined part of the aquifer where the redox condition is different it is necessary to use a geochemical model based on the U concentration in the water, the 226 Ra gives in such case ages varying from 1.8ka to 12.8ka. The radiocarbon ages obtained through usual chemical and/or isotopic models are quite similar and an isochrome between 226 Ra and 14 C ages can be calculated between 0 and 8ka

  14. Electrospray ionisation mass spectrometry facilitates detection of fibrinogen (Bbeta 14 Arg --> Cys) mutation in a family with thrombosis.

    Science.gov (United States)

    Brennan, S O; Hammonds, B; Spearing, R; George, P M

    1997-12-01

    We report the first direct detection of a fibrinogen mutation by electrospray ionisation mass spectrometry. The propositus, from a family with a history of thrombosis, came to attention after a pulmonary embolism subsequent to a spontaneous abortion. Prolonged thrombin (41 s) and reptilase times (26 s) together with an impairment of fibrinopeptide B release suggested a mutation at the thrombin cleavage site of the Bbeta chain. Direct mass analysis of purified fibrin chains from a thrombin induced clot showed that 50% of the Bbeta chains remained uncleaved. The measured mass of the mono sialo isoform of this uncleaved chain was 54150 Da, compared to a value of 54198 Da for normal Bbeta chains. This decrease of 48 Da in the intact protein is indicative of either a Bbeta 14 Arg to Cys, or Arg to Leu substitution. Heterozygosity for the Bbeta 14 Arg --> Cys mutation was verified by PCR amplification and DNA sequence analysis.

  15. Matrix-assisted laser desorption/ionisation mass spectrometry imaging and its development for plant protein imaging

    Directory of Open Access Journals (Sweden)

    Millar A Harvey

    2011-07-01

    Full Text Available Abstract Matrix-Assisted Laser Desorption/Ionisation (MALDI mass spectrometry imaging (MSI uses the power of high mass resolution time of flight (ToF mass spectrometry coupled to the raster of lasers shots across the cut surface of tissues to provide new insights into the spatial distribution of biomolecules within biological tissues. The history of this technique in animals and plants is considered and the potential for analysis of proteins by this technique in plants is discussed. Protein biomarker identification from MALDI-MSI is a challenge and a number of different approaches to address this bottleneck are discussed. The technical considerations needed for MALDI-MSI are reviewed and these are presented alongside examples from our own work and a protocol for MALDI-MSI of proteins in plant samples.

  16. Field studies on long term ecosystem consequences of ionising radiation and chemical pollutants (EANOR Project)

    Energy Technology Data Exchange (ETDEWEB)

    Oughton, D. [Centre for Environmental Radioactivity - CERAD (Norway); Evseeva, T. [Institute of Biology RAS (Russian Federation); Erenturk, S. [Istanbul Technical University (Turkey)

    2014-07-01

    Chernobyl and other nuclear accidents have demonstrated that high levels of ionizing radiation can result in impacts on plants and animals, however little is known about the long-term effects of chronic exposure on biodiversity or other population and ecosystem level effects. The issue of ecological impact has been addressed after the Fukushima accident, which has raised questions about the impacts of radioactivity not only on human health, but also on wildlife. The overall aim of the EANOR project (2012-2015) is to assess the impacts of chronic exposure to enhanced radioactivity and chemical pollutants by studying the diversity of plant and soil invertebrate populations at two field sites. The first is a radium contaminated site in the Vodny area of the Komi Republic, Russia. Between 1931 and 1956, this was the main location of Soviet radium production. Wastes from the industry caused contamination of the environment, leading to high levels of radionuclides, heavy metals and rare-earth elements in the surroundings. The prolonged exposure of the ecosystem, combined with relatively low human activities, makes the site an excellent field laboratory for investigating the long-term effects of pollution. The second site is metal mining (Fe, Au, Ag, Mn, Mo, Cu, Pb and Zn) and industrial area on the Eastern Black Sea Region, Turkey, having elevated levels of both heavy metals and radionuclides for many decades. Eastern Black Sea Region is a mountainous area covered with dense forests, where numerous rivers and torrents flow through gorges and is characterized by heavy rainfall, humid summers, and mild winters. Based on these conditions, the region is rich in biological diversity. Joint field expeditions have been carried out in 2012 and 2013 with the objective of documenting levels of radionuclides and other chemical contaminants in soils and organisms, and assessing plant and soil invertebrate biodiversity. Measurement of a range of biomarkers, including soil meta

  17. Determination of iodine at ppt level in a nitric acid medium by inductively coupled plasma sector field mass spectrometry: influence of the chemical forms; Etude de la determination de traces d'iode en solution par spectrometrie de masse a secteur magnetique utilisant un plasma a couplage inductif comme source d'ionisation: influence de la forme chimique

    Energy Technology Data Exchange (ETDEWEB)

    Langlois, B

    2001-07-01

    Inductively Coupled Plasma Sector Field Mass Spectrometry (ICP/SFMS) was used to determine several chemical forms of iodine, at ppt level, in a nitric acid media. Ascorbic acid was added as a reducing agent in order to maintain iodine as iodide. In a preliminary approach, the influence of the chemical form was studied by comparing inorganic iodine (NaI) and organic iodine (CH3I). Different signal responses were observed. With a conventional sample introduction system, sensitivities obtained for iodo-methane could differ by a factor of 5. This was not caused by a problem of atomization or by a change in the ionization efficiency of the iodo-compound into the plasma. The low volatilization temperature of iodo-methane (315.5 K) seemed to be the main explanation of this phenomena. Actually, nebulization resulted in the volatilization of a 2% nitric acid solution containing iodo-methane. As a result, the transport efficiency of iodo-methane between the nebulizer and the torch was approaching 100%. A Direct Injection High Efficiency Nebulizer (DIHEN) allowed us to minimize the behavior difference between the two iodine species, but the sensitivity ratio was inverted and still differed by 20 - 40%. Moreover, the association of a guard electrode and the direct injection system was studied in order to apply these equipments to the determination of iodine. This association allowed us to improve the sensitivity by a factor of 10 and to minimize memory effects, when compared with a conventional system. Further studies indicated that signal responses obtained with different iodine-containing species, except for iodo-methane, were found to be similar. (author)

  18. Rapid and simultaneous determination of polychlorinated biphenyls and their main metabolites (hydroxylated and methyl sulfonyl) by gas chromatography coupled to mass spectrometry: Comparison of different ionisation modes

    International Nuclear Information System (INIS)

    Castro-Puyana, M.; Herrero, L.; González, M.J.; Gómara, B.

    2013-01-01

    Graphical abstract: -- Highlights: •Simultaneous determination of PCB, OH-PCBs and MeSO 2 -PCBs in a single GC–MS run. •Two different ionisation modes (EI and ECNI) are studied and compared. •The analytical characterisation of both methods is satisfactory. •Better LODs are achieved using ECNI-MS as ionisation mode. •The developed methodology is successfully applied to fish liver oil. -- Abstract: Instrumental methods based on gas chromatography coupled to mass spectrometry (GC–MS) have been developed and compared using two different MS ionisation modes, electron impact (EI) and electron capture negative ionisation (ECNI), for the fast, quantitative and simultaneous determination of polychlorinated biphenyls (PCBs) and their main metabolites (hydroxylated PCBs, OH-PCBs, and methyl sulfone PCBs, MeSO 2 -PCBs). Parameters affecting chromatographic separation and MS detection were evaluated in order to achieve the highest selectivity and sensitivity for both operation modes. The analytical characteristics of the developed methods were studied and compared in terms of linear range, limits of detection (LODs), limits of quantification (LOQs), and instrumental precision (repeatability and intermediate precision). Both ionisation methods showed similar precision, being relative standard deviations (RSD, %) lower than 9% and 14% for repeatability and intermediate precision, respectively. However, better LODs (from 0.01 to 0.14 pg injected for the three families of congeners studied) were achieved using ECNI-MS as ionisation mode. The suitability of the developed method was demonstrated through their application to fish liver oil samples

  19. Looking into individual coffee beans during the roasting process: direct micro-probe sampling on-line photo-ionisation mass spectrometric analysis of coffee roasting gases.

    Science.gov (United States)

    Hertz-Schünemann, Romy; Streibel, Thorsten; Ehlert, Sven; Zimmermann, Ralf

    2013-09-01

    A micro-probe (μ-probe) gas sampling device for on-line analysis of gases evolving in confined, small objects by single-photon ionisation time-of-flight mass spectrometry (SPI-TOFMS) was developed. The technique is applied for the first time in a feasibility study to record the formation of volatile and flavour compounds during the roasting process within (inside) or in the direct vicinity (outside) of individual coffee beans. A real-time on-line analysis of evolving volatile and semi-volatile organic compounds (VOC and SVOC) as they are formed under the mild pyrolytic conditions of the roasting process was performed. The soft-ionisation mass spectra depict a molecular ion signature, which is well corresponding with the existing knowledge of coffee roasting and evolving compounds. Additionally, thereby it is possible to discriminate between Coffea arabica (Arabica) and Coffea canephora (Robusta). The recognized differences in the roasting gas profiles reflect the differences in the precursor composition of the coffee cultivars very well. Furthermore, a well-known set of marker compounds for Arabica and Robusta, namely the lipids kahweol and cafestol (detected in their dehydrated form at m/z 296 and m/z 298, respectively) were observed. If the variation in time of different compounds is observed, distinctly different evolution behaviours were detected. Here, phenol (m/z 94) and caffeine (m/z 194) are exemplary chosen, whereas phenol shows very sharp emission peaks, caffeine do not have this highly transient behaviour. Finally, the changes of the chemical signature as a function of the roasting time, the influence of sampling position (inside, outside) and cultivar (Arabica, Robusta) is investigated by multivariate statistics (PCA). In summary, this pilot study demonstrates the high potential of the measurement technique to enhance the fundamental knowledge of the formation processes of volatile and semi-volatile flavour compounds inside the individual coffee bean.

  20. Negative chemical ionization mass spectrometry

    International Nuclear Information System (INIS)

    Smit, A.L.C.

    1979-01-01

    This thesis describes some aspects of Negative Chemical Ionization (NCI) mass spectrometry. The reasons for the growing interest in NCI are: (i) to extend the basic knowledge of negative ions and their reactions in the gas phase; (ii) to investigate whether or not this knowledge of negative ions can be used successfully to elucidate the structure of molecules by mass spectrometry. (Auth.)

  1. Visualisation of abscisic acid and 12-oxo-phytodienoic acid in immature Phaseolus vulgaris L. seeds using desorption electrospray ionisation-imaging mass spectrometry

    Science.gov (United States)

    Enomoto, Hirofumi; Sensu, Takuya; Sato, Kei; Sato, Futoshi; Paxton, Thanai; Yumoto, Emi; Miyamoto, Koji; Asahina, Masashi; Yokota, Takao; Yamane, Hisakazu

    2017-02-01

    The plant hormone abscisic acid (ABA) and the jasmonic acid related-compound 12-oxo-phytodienoic acid (OPDA) play crucial roles in seed development, dormancy, and germination. However, a lack of suitable techniques for visualising plant hormones has restricted the investigation of their biological mechanisms. In the present study, desorption electrospray ionisation-imaging mass spectrometry (DESI-IMS), a powerful tool for visualising metabolites in biological tissues, was used to visualise ABA and OPDA in immature Phaseolus vulgaris L. seed sections. The mass spectra, peak values and chemical formulae obtained from the analysis of seed sections were consistent with those determined for ABA and OPDA standards, as were the precursor and major fragment ions observed in tandem mass spectrometry (MS/MS) imaging. Furthermore, the precursor and fragment ion images showed similar distribution patterns. In addition, the localisation of ABA and OPDA using DESI-IMS was confirmed using liquid chromatography-MS/MS (LC-MS/MS). The results indicated that ABA was mainly distributed in the radical and cotyledon of the embryo, whereas OPDA was distributed exclusively in external structures, such as the hilum and seed coat. The present study is the first to report the visualisation of plant hormones using IMS, and demonstrates that DESI-IMS is a promising technique for future plant hormone research.

  2. Real-time analysis of organic compounds in ship engine aerosol emissions using resonance-enhanced multiphoton ionisation and proton transfer mass spectrometry.

    Science.gov (United States)

    Radischat, Christian; Sippula, Olli; Stengel, Benjamin; Klingbeil, Sophie; Sklorz, Martin; Rabe, Rom; Streibel, Thorsten; Harndorf, Horst; Zimmermann, Ralf

    2015-08-01

    Organic combustion aerosols from a marine medium-speed diesel engine, capable to run on distillate (diesel fuel) and residual fuels (heavy fuel oil), were investigated under various operating conditions and engine parameters. The online chemical characterisation of the organic components was conducted using a resonance-enhanced multiphoton ionisation time-of-flight mass spectrometer (REMPI TOF MS) and a proton transfer reaction-quadrupole mass spectrometer (PTR-QMS). Oxygenated species, alkenes and aromatic hydrocarbons were characterised. Especially the aromatic hydrocarbons and their alkylated derivatives were very prominent in the exhaust of both fuels. Emission factors of known health-hazardous compounds (e.g. mono- and poly-aromatic hydrocarbons) were calculated and found in higher amounts for heavy fuel oil (HFO) at typical engine loadings. Lower engine loads lead in general to increasing emissions for both fuels for almost every compound, e.g. naphthalene emissions varied for diesel fuel exhaust between 0.7 mg/kWh (75 % engine load, late start of injection (SOI)) and 11.8 mg/kWh (10 % engine load, late SOI) and for HFO exhaust between 3.3 and 60.5 mg/kWh, respectively. Both used mass spectrometric techniques showed that they are particularly suitable methods for online monitoring of combustion compounds and very helpful for the characterisation of health-relevant substances. Graphical abstract Three-dimensional REMPI data of organic species in diesel fuel and heavy fuel oil exhaust.

  3. Identification of Wheat Varieties Using Matrix-assisted Laser Desorption/Ionisation Time-of-flight Mass Spectrometry and an Artificial Neural network

    DEFF Research Database (Denmark)

    Bloch, Helle Aagaard; Kesmir, Can; Petersen, Marianne Kjerstine

    1999-01-01

    A novel tool for variety identification of wheat (Triticum aestivum L,) has been developed: an artificial neural network (ANN) is used to classify the gliadin fraction analysed by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS). The robustness...

  4. Can laser-ionisation time-of-flight mass spectrometry be a promising alternative to laser ablation/inductively-coupled plasma mass spectrometry and glow discharge mass spectrometry for the elemental analysis of solids?

    NARCIS (Netherlands)

    Sysoev, AA; Sysoev, AA

    2002-01-01

    At the beginning of the age of laser-ionisation mass spectrometry (LIMS) increasing numbers of publications were observed. However, later the method began to run into obstacles associated with poor reproducibility of analysis and large variations in elemental sensitivities so that the wide interest

  5. Measurement of small ion beams by thermal ionisation mass spectrometry using new 10(13) Ohm resistors.

    Science.gov (United States)

    Koornneef, J M; Bouman, C; Schwieters, J B; Davies, G R

    2014-03-28

    We tested 5 newly manufactured - prototype - 10(13)Ohm resistors in the feedback loop of Faraday cup amplifiers to measure small ion beams by Thermal Ionisation Mass Spectrometry (TIMS). The high Ohmic resistors installed in the TRITON Plus at the VU University Amsterdam theoretically have 10 times lower noise levels relative to the default 10(11)Ohm resistors. To investigate the precision and accuracy of analyses using these new amplifiers we measured Sr and Nd isotopes of reference standards at a range of ion currents (3.2×10(-16) to 1×10(-12) A, corresponding to intensities of 32 μV to 100 mV on a default 10(11)Ohm amplifier) and on small amounts of material (100 and 10 pg). Internal precision and external reproducibility for Sr and Nd isotope ratios are both better when collected on 10(13) compared 10(12)Ohm resistors and to the default 10(11)Ohm resistors. At an (87)Sr ion current of 3×10(-14) A (3 mV on a 10(11)Ohm amplifier) the internal precision (2 SE) of (87)Sr/(86)Sr is 5 times better for 10(13)Ohm resistors compared to 10(11)Ohm resistors. The external reproducibility (2 SD) at this beam intensity is 9 times better. Multiple 100 and 10 pg Sr standards, ran to exhaustion, yielded low (87)Sr/(86)Sr compared to the long term average (e.g. 10 pg average=0.710083±164 (n=11) instead of 0.710244±12, n=73). The average off-set for 10 pg standards can be explained by a loading blank contribution of 1.3 pg. In contrast, Nd data on 100 pg and 10 pg samples are accurate suggesting that Nd loading blanks do not compromise the data. The external reproducibility of (143)Nd/(144)Nd on 100 pg samples is 125 ppm and 3.3‰ on 10 pg samples (2 RSD=relative standard deviation, n=10). Thus, variability in Nd and Sr isotope ratios in the 4th decimal place, e.g. (143)Nd/(144)Nd 0.5110-0.5119 or (87)Sr/(86)Sr 0.7100-0.7109, can be resolved in 10 to 100 pg samples provided that the procedural blanks and chemical separation are optimal. For measurements in the beam

  6. Desorption electrospray ionisation mass spectrometry: A rapid screening tool for veterinary drug preparations and forensic samples from hormone crime investigations

    International Nuclear Information System (INIS)

    Nielen, M.W.F.; Hooijerink, H.; Claassen, F.C.; Engelen, M.C. van; Beek, T.A. van

    2009-01-01

    Hormone and veterinary drug screening and forensics can benefit from the recent developments in desorption electrospray ionisation (DESI) mass spectrometry (MS). In this work the feasibility of DESI application has been studied. Using a linear ion trap or quadrupole time-of-flight (TOF) MS instrument both full-scan and data-dependent collision-induced dissociation MS n spectra were acquired in seconds without sample preparation. Preliminary data are presented for the rapid screening of (pro)hormone supplement samples, an illegal steroid cocktail and forensic samples from veterinary drug investigations. The potential of this DESI approach is clearly demonstrated since compounds observed could be independently confirmed by liquid chromatography/TOFMS with accurate mass measurement, and/or proton nuclear magnetic resonance spectroscopy. Specific concerns related to false-positive and false-negative findings due to limitations in quantification and memory-effects are briefly discussed. It is envisaged that DESI will achieve a prominent role in hormone and veterinary drug analysis in the near future

  7. Desorption electrospray ionisation mass spectrometry: A rapid screening tool for veterinary drug preparations and forensic samples from hormone crime investigations

    Energy Technology Data Exchange (ETDEWEB)

    Nielen, M.W.F. [RIKILT Institute of Food Safety, P.O. Box 230, 6700 AE Wageningen (Netherlands); Wageningen University, Laboratory of Organic Chemistry, Dreijenplein 8, 6703 HB Wageningen (Netherlands)], E-mail: michel.nielen@wur.nl; Hooijerink, H. [RIKILT Institute of Food Safety, P.O. Box 230, 6700 AE Wageningen (Netherlands); Claassen, F.C. [Wageningen University, Laboratory of Organic Chemistry, Dreijenplein 8, 6703 HB Wageningen (Netherlands); Engelen, M.C. van [RIKILT Institute of Food Safety, P.O. Box 230, 6700 AE Wageningen (Netherlands); Beek, T.A. van [Wageningen University, Laboratory of Organic Chemistry, Dreijenplein 8, 6703 HB Wageningen (Netherlands)

    2009-04-01

    Hormone and veterinary drug screening and forensics can benefit from the recent developments in desorption electrospray ionisation (DESI) mass spectrometry (MS). In this work the feasibility of DESI application has been studied. Using a linear ion trap or quadrupole time-of-flight (TOF) MS instrument both full-scan and data-dependent collision-induced dissociation MS{sup n} spectra were acquired in seconds without sample preparation. Preliminary data are presented for the rapid screening of (pro)hormone supplement samples, an illegal steroid cocktail and forensic samples from veterinary drug investigations. The potential of this DESI approach is clearly demonstrated since compounds observed could be independently confirmed by liquid chromatography/TOFMS with accurate mass measurement, and/or proton nuclear magnetic resonance spectroscopy. Specific concerns related to false-positive and false-negative findings due to limitations in quantification and memory-effects are briefly discussed. It is envisaged that DESI will achieve a prominent role in hormone and veterinary drug analysis in the near future.

  8. A liquid chromatography/electrospray ionisation tandem mass spectrometry method for the simultaneous quantification of salicylic, jasmonic and abscisic acids in Coffea arabica leaves.

    Science.gov (United States)

    de Sá, Marta; Ferreira, João P; Queiroz, Vagner T; Vilas-Boas, Luís; Silva, Maria C; Almeida, Maria H; Guerra-Guimarães, Leonor; Bronze, Maria R

    2014-02-01

    Plants have developed an efficient system of recognition that induces a complex network of signalling molecules such as salicylic acid (SA), jasmonic acid (JA) and abscisic acid (ABA) in case of a pathogenic infection. The use of specific and sensitive methods is mandatory for the analysis of compounds in these complex samples. In this study a liquid chromatography/electrospray ionisation tandem mass spectrometry method was developed and validated for the simultaneous quantification of SA, JA and ABA in Coffea arabica (L.) leaves in order to understand the role of these phytohormones in the signalling network involved in the coffee defence response against Hemileia vastatrix. The results showed that the method was specific, linear (r ≥ 0.99) in the range 0.125-1.00 µg mL⁻¹ for JA and ABA and 0.125-5.00 µg mL⁻¹ for SA, and precise (relative standard deviation ≤11%), and the limit of detection (0.010 µg g⁻¹ fresh weight) was adequate for quantifying these phytohormones in this type of matrix. In comparison with healthy leaves, those infected with H. vastatrix (resistance reaction) displayed an increase in SA level 24 h after inoculation, suggesting the involvement of an SA-dependent pathway in coffee resistance. © 2013 Society of Chemical Industry.

  9. Introduction to computer control and future aspects in thermal ionisation mass spectrometry

    International Nuclear Information System (INIS)

    Hagemann, R.

    The author considers the computer control of the measurement program which is already available in modern mass spectrometers. Future areas for computer control are considered e.g. the heating program, ion optics and focusing, and sample changer control. (Auth.)

  10. Introduction to computer control and future aspects in thermal ionisation mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hagemann, R. [CEA Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1978-12-15

    The author considers the computer control of the measurement program which is already available in modern mass spectrometers. Future areas for computer control are considered e.g. the heating program, ion optics and focusing, and sample changer control.

  11. Rapid evaporative ionisation mass spectrometry and chemometrics for high-throughput screening of growth promoters in meat producing animals.

    Science.gov (United States)

    Guitton, Yann; Dervilly-Pinel, Gaud; Jandova, Renata; Stead, Sara; Takats, Zoltan; Le Bizec, Bruno

    2018-01-17

    In a proof of concept perspective, Rapid Evaporative Ionisation Mass Spectrometry (REIMS) was explored for the direct analysis of meat samples from β-agonist treated livestock. In this context, the combination of REIMS with untargeted metabolomics was investigated to identify carcasses from treated animals on the basis of a modification of indirect metabolites profile. The REIMS analysis generated specific lipid profiles which enabled the differentiation of meat samples collected from pigs treated with ractopamine via their feeding regime. Furthermore, the strategy was found successful when tested on different muscle types (loin, shoulder and thigh), which further expands its applicability. Classification performances were greater than 95% accurate which fully answers requirements of a screening strategy. This research indicates that REIMS implemented in an untargeted-metabolomics workflow can be considered as a high-throughput and accurate strategy for real-time meat classification in relation to ractopamine (and wider β-agonists) treatment in pig production. This approach may subsequently be implemented as a rapid screening test, at the slaughterhouse or at border inspection points, to detect such practice.

  12. Use of the Isomass 54E thermal ionisation mass spectrometer at AEE Winfrith

    International Nuclear Information System (INIS)

    Knight, A.P.

    1982-03-01

    A Vacuum Generators Isomass 54E mass spectrometer is used to carry out isotopic analyses. The capabilities of the instrument and its method of operation are outlined, and the technique used for isotopic analysis of uranium is described in detail, with results of tests on NBS standard specimens and Zebra fuel element pellets. (U.K.)

  13. European Code against Cancer 4th Edition: Ionising and non-ionising radiation and cancer

    NARCIS (Netherlands)

    N. McColl (Neil); A. Auvinen (Anssi); A. Kesminiene (Ausrele); C. Espina (Carolina); F. Erdmann (Friederike); E. de Vries (Esther); R. Greinert (Rüdiger); J. Harrison (John); J. Schüz (Joachim)

    2015-01-01

    textabstractIonising radiation can transfer sufficient energy to ionise molecules, and this can lead to chemical changes, including DNA damage in cells. Key evidence for the carcinogenicity of ionising radiation comes from: follow-up studies of the survivors of the atomic bombings in Japan; other

  14. Characterisation of Bacteria by Matrix- assisted Laser Desorption/Ionisation and Electrospray Mass Spectrometry.

    Science.gov (United States)

    1999-12-01

    with biological activity testing, was reported for the peptidoglycan of Strepto- coccus sanguis [114]. Amino acid substitution of the oligomeric... pesticides trapping and preconcentration column technology developed for water analysis [132]. The SP and SPIA approach seem amenable to the characteri...American Chemical Society, Washington, DC, pp. 62-84. [14] Voorhees, K.J.; Basile , F.; Beverly, M.B.; Abbashawks, C; Hendricker, A.; Cody, R.B. and

  15. Ionising radiation

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    The law covering ionising radiation in Luxembourg is summarised under the headings: introduction (the outline law of 25 March 1963, and the Grand-Ducal Decree of 8 February 1967); the control of establishments (the authorisation procedure; emergency measures, suspension and withdrawal of the authorisation; alterations to the establishment); the importation, distribution and transit of radioactive substances; the transport of radioactive substances; the protection and safety of the population as a whole; sanctions; international conventions. (U.K.)

  16. Characterisation of homoflavonoids from three Ophioglossum species using liquid chromatography with diode array detection and electrospray ionisation tandem mass spectrometry.

    Science.gov (United States)

    Wan, Chuan-Xing; Luo, Jian-Guang; Gu, Yu-Cheng; Xu, De-Ran; Kong, Ling-Yi

    2013-01-01

    Homoflavonoids, characterised by one more carbon atom directly added to C6 -C3 -C6 backbone of flavonoids, are rich in the species of genus Ophioglossum. Up to now we have little knowledge about their MS fragmentation patterns. It is therefore necessary to investigate their MS fragmentation pathways so as to distinguish them from other types of flavonoids. To develop a rapid method for identifying homoflavonoids from Ophioglossum based on their characteristic MS fragmentation. Mass spectrometry fragmentation pathways and qualitative analysis of homoflavonoids in three ferns of Ophioglosssum were investigated by using high-performance liquid chromatography coupled with diode-array detection and electrospray ionisation tandem mass spectrometry (HPLC-DAD-ESI/MS(n) ). The analyses of the MS(n) spectra of the homoflavonoids allowed us to classify them into two types according to their fragmentation characteristics. The type I homoflavonoids, with an attached additional carbon atom to the C-3 position of the C-ring, presented the initial competing loss of H2 O and CH2 O from their aglycone ions, compared to the initial removal of H2 O or CO in the case of the type II homoflavonoids, which bear the additional carbon atom at the C-2' site of the B-ring and forming ring D. The above characteristic fragmentations of homoflavonoids were quite different from those of other flavonoids, and were successfully applied to identify homoflavonoids in the crude extracts of three Ophioglossum species. The HPLC-DAD-ESI/MS(n) method obtained in the present study provided a powerful tool for identifying homoflavonoids from ferns in the genus Ophioglossum. Copyright © 2013 John Wiley & Sons, Ltd.

  17. Identification of barley and rye varieties using matrix- assisted laser desorption/ionisation time-of-flight mass spectrometry with neural networks

    DEFF Research Database (Denmark)

    Bloch, H.A.; Petersen, Marianne Kjerstine; Sperotto, Maria Maddalena

    2001-01-01

    developed, which combines analysis of alcohol-soluble wheat proteins (gliadins) using matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry with neural networks. Here we have applied the same method for the identification of both barley (Hordeum vulgare L.) and rye (Secale cereale L.......) varieties. For barley, 95% of the mass spectra were correctly classified. This is an encouraging result, since in earlier experiments only a grouping into subsets of varieties was possible. However, the method was not useful in the classification of rye, due to the strong similarity between mass spectra...

  18. An on-line mass-separator for thermically ionisable fission products: OSTIS

    International Nuclear Information System (INIS)

    Wuensch, K.-D.

    1978-01-01

    A mass separator has been designed and built for the installed at an external neutron guide tube (flux approximately 10 9 nsub(th)/s cm 2 ) of the High Flux Reactor of the Institute Laue-Langevin in Grenoble. The ion source consists of a high temperature oven containing fissile target material (approximately 2 g 235 U) embedded in porous carbon. Fission products formed in the target are thermalised in the carbon where only the alkali fission products diffuse quickly to the extraction hole. There only Rb and Cs are thermally ionized. Accelerated to 20 kV, these ions pass through a deflecting magnetic field (rhosub(m) approximately 215 mm, rho=77.5 0 ) for mass analysis and an electrostatic quadrupole to form a 5 mm diameter spot about 1 m outside the concrete shielding. Intensities of some 10 6 atoms per second were reached. The system allows all types of nuclear spectroscopy of Rb, Cs and their β-decay chain daughters as well as the measurement of yields and fission neutrons. It has been in nearly continuous operation for more than two years in Grenoble and first results are reported. (Auth.)

  19. Analysis of the monosaccharide composition of water-soluble polysaccharides from Sargassum fusiforme by high performance liquid chromatography/electrospray ionisation mass spectrometry.

    Science.gov (United States)

    Wu, Xiaodan; Jiang, Wei; Lu, Jiajia; Yu, Ying; Wu, Bin

    2014-02-15

    Sargassum fusiforme (hijiki) is the well-known edible algae, whose polysaccharides have been proved to possess interesting bioactivities like antitumor, antioxidant, antimicrobial and immunomodulatory activities. A facile and sensitive method based on high-performance liquid chromatography method of pre-column derivatization with 1-phenyl-3-methyl-5-pyrazolone (PMP) coupled with electrospray ionisation mass spectrometry (HPLC/ESI-MS) has been established for the analysis of the monosaccharide composition of polysaccharides in S. fusiforme. Monosaccharides have been converted into PMP-labelled derivatives with aqueous ammonia as a catalyst at 70 °C for 30 min. The optimisation of the pre-column derivatization process was studied. The LODs of the monosaccharides were in the range from 0.01 to 0.02 nmol. PMP-labelled mixture of monosaccharides has been well separated by a reverse-phase HPLC and detected by on-line ESI-MS method under optimised conditions. The mobile phase of elution system was chosen as acetonitrile (solvent A) and 20mM aqueous ammonium acetate (solvent B) (pH 3.0) with Zorbax XDB-C18 column at 30 °C for the separation of the monosaccharide derivatives. Identification of the monosaccharides composition was carried out by analysis with mass spectral behaviour and chromatography characteristics of 1-phenyl-3-methyl-5-pyrazolone (PMP) labelled monosaccharides. All PMP-labelled derivatives display high chemical stabilities, whose regular MS fragmentation is specific for reducing labelled sugars. The result showed that the S. fusiforme polysaccharide consisted of mannose, glucose, galactose, xylose, fucose and glucuronic acid or galacturonic acid, or both uronic acids. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Matrix-assisted laser desorption/ionisation, time-of-flight mass spectrometry in genomics research.

    Directory of Open Access Journals (Sweden)

    Jiannis Ragoussis

    2006-07-01

    Full Text Available The beginning of this millennium has seen dramatic advances in genomic research. Milestones such as the complete sequencing of the human genome and of many other species were achieved and complemented by the systematic discovery of variation at the single nucleotide (SNP and whole segment (copy number polymorphism level. Currently most genomics research efforts are concentrated on the production of whole genome functional annotations, as well as on mapping the epigenome by identifying the methylation status of CpGs, mainly in CpG islands, in different tissues. These recent advances have a major impact on the way genetic research is conducted and have accelerated the discovery of genetic factors contributing to disease. Technology was the critical driving force behind genomics projects: both the combination of Sanger sequencing with high-throughput capillary electrophoresis and the rapid advances in microarray technologies were keys to success. MALDI-TOF MS-based genome analysis represents a relative newcomer in this field. Can it establish itself as a long-term contributor to genetics research, or is it only suitable for niche areas and for laboratories with a passion for mass spectrometry? In this review, we will highlight the potential of MALDI-TOF MS-based tools for resequencing and for epigenetics research applications, as well as for classical complex genetic studies, allele quantification, and quantitative gene expression analysis. We will also identify the current limitations of this approach and attempt to place it in the context of other genome analysis technologies.

  1. Electrochemical separation and isotopic determination of thallium at the nanogram level by surface ionisation mass spectrometry

    International Nuclear Information System (INIS)

    Arden, J.W.

    1983-01-01

    A rapid low-blank procedure is described for the co-separation of thallium and lead by sequential cathodic and anodic electrodeposition from natural samples, especially complex natural silicates, for subsequent mass spectrometry. A micro anion-exchange procedure is also described for the separation of thallium and lead. Ion currents of 10 - 10 A can be obtained from 1 ng of thallium. The isotopic composition of 1 ng of thallium can be measured on a Faraday detector with a precision of 0.05-0.1%. The total procedural blank is 3 pg. By using stable isotope dilution, 0.2 ng of thallium can be measured with a precision of 0.6% with only a 2% blank correction. This allows the accurate determination of thallium in natural samples down to concentration levels of about 50 pg g - 1 . The detection limit is 50 fg. This procedure has been applied to meteorites and terrestrial rocks. The stable isotope dilution technique is suitable for geochemical, environmental and toxicological studies requiring a highly sensitive, accurate and precise method for the determination of thallium. (Auth.)

  2. Identification of organic pigments in tattoo inks and permanent make-up using laser desorption ionisation mass spectrometry.

    Science.gov (United States)

    Niederer, Markus; Hauri, Urs; Kroll, Lydia; Hohl, Christopher

    2017-01-01

    Nowadays, about 12% of the European and 20% of the US population are tattooed. Rising concerns regarding consumer safety, led to legal restrictions on tattoo and permanent make-up (PMU) inks. Restrictions also include bans on certain colourants. Both ink types use organic pigments for colour-giving, plus inorganic pigments for white and black and colour tones. Pigments are only sparingly soluble in common solvents and occur as suspended particles in the ink matrix. Their detection and identification therefore pose a major challenge for laboratories involved in monitoring the legal compliance of tattoo inks and PMU. We overcame this challenge by developing a direct laser desorption ionisation time-of-flight mass spectrometry method, which included an easy sample clean up. The method proved to be capable of detecting and identifying organic pigments in almost all of the tested ink samples. Method validation and routine deployment during market surveys showed the method to be fit for purpose. Pigment screening of 396 tattoo inks and 55 PMU taken from the Swiss market between 2009 and 2017 lead to the following conclusions: Pigment variety is much greater in tattoo inks (18) than in PMU (10); four prohibited pigments (Pigment Green 7, Pigment Red 122, Pigment Violet 19 and 23) were found in both ink types; for PMU, these four pigments made up 12% of the pigment findings, compared to 32% for tattoo inks. Therefore, legal compliance of PMU was at a higher level. A comparison of pigments found with those declared on tattoo ink labels clearly showed that banned pigments are rarely declared, but rather masked by listing non present legal pigments and label forging; therefore, highlighting the urgency of widespread market controls.

  3. Characterisation of thorium-ethylenediaminetetraacetic acid and thorium-nitrilotriacetic acid species by electrospray ionisation-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Cartwright, Andrew J. [Biogeochemistry and Environmental Analytical Chemistry Group, School of Earth, Ocean and Environmental Sciences, University of Plymouth, Drake Circus, Plymouth PL4 8AA (United Kingdom); May, Colin C. [Biogeochemistry and Environmental Analytical Chemistry Group, School of Earth, Ocean and Environmental Sciences, University of Plymouth, Drake Circus, Plymouth PL4 8AA (United Kingdom); Worsfold, Paul J. [Biogeochemistry and Environmental Analytical Chemistry Group, School of Earth, Ocean and Environmental Sciences, University of Plymouth, Drake Circus, Plymouth PL4 8AA (United Kingdom); Keith-Roach, Miranda J. [Biogeochemistry and Environmental Analytical Chemistry Group, School of Earth, Ocean and Environmental Sciences, University of Plymouth, Drake Circus, Plymouth PL4 8AA (United Kingdom)]. E-mail: mkeith-roach@plymouth.ac.uk

    2007-05-02

    Electrospray ionisation-mass spectrometry (ESI-MS) has been used to investigate the speciation of Th in the presence of two common organic complexing agents found in radioactive wastes, EDTA and NTA. These ligands may enhance radionuclide migration from nuclear wastes and contaminated land, and characterisation of the complexes formed will improve our understanding of their environmental mobility. When acetic acid and ammonia were used to adjust the pH, the dominant Th-EDTA species changed from the mixed ligand [ThEDTAac]{sup -} complex to [ThEDTAOH]{sup -} and [ThEDTA(OH){sub 2}ac]{sup 3-} as the pH increased, with all species co-existing, to some extent, over the pH range (2.5-10.8). A previously suggested Th-NTA species, [ThNTA{sub 2}]{sup 2-}, dominates from pH 6.0-8.5 but at high pH (10.0-10.8) NTA was not able to solubilise Th to a measurable extent. In the presence of both EDTA and NTA, Th formed a mixed ligand complex, [ThEDTANTA]{sup 3-} which has also been characterised in independent experiments. The identification of the importance of [ThNTA{sub 2}]{sup 2-}, [ThEDTANTA]{sup 3-} and [ThEDTA(OH){sub 2}]{sup 2-} (with an additional acetate ligand) highlights that these species are not included in current speciation databases and thus may impact on predictions of the environmental mobility of Th. ESI-MS has therefore been used to identify and confirm fundamentally important Th complexes. It has proved to be a useful tool for elucidating radionuclide speciation, adding to our knowledge of Th geochemistry and providing a means of critically examining existing stability constant data.

  4. Characterisation of thorium-ethylenediaminetetraacetic acid and thorium-nitrilotriacetic acid species by electrospray ionisation-mass spectrometry

    International Nuclear Information System (INIS)

    Cartwright, Andrew J.; May, Colin C.; Worsfold, Paul J.; Keith-Roach, Miranda J.

    2007-01-01

    Electrospray ionisation-mass spectrometry (ESI-MS) has been used to investigate the speciation of Th in the presence of two common organic complexing agents found in radioactive wastes, EDTA and NTA. These ligands may enhance radionuclide migration from nuclear wastes and contaminated land, and characterisation of the complexes formed will improve our understanding of their environmental mobility. When acetic acid and ammonia were used to adjust the pH, the dominant Th-EDTA species changed from the mixed ligand [ThEDTAac] - complex to [ThEDTAOH] - and [ThEDTA(OH) 2 ac] 3- as the pH increased, with all species co-existing, to some extent, over the pH range (2.5-10.8). A previously suggested Th-NTA species, [ThNTA 2 ] 2- , dominates from pH 6.0-8.5 but at high pH (10.0-10.8) NTA was not able to solubilise Th to a measurable extent. In the presence of both EDTA and NTA, Th formed a mixed ligand complex, [ThEDTANTA] 3- which has also been characterised in independent experiments. The identification of the importance of [ThNTA 2 ] 2- , [ThEDTANTA] 3- and [ThEDTA(OH) 2 ] 2- (with an additional acetate ligand) highlights that these species are not included in current speciation databases and thus may impact on predictions of the environmental mobility of Th. ESI-MS has therefore been used to identify and confirm fundamentally important Th complexes. It has proved to be a useful tool for elucidating radionuclide speciation, adding to our knowledge of Th geochemistry and providing a means of critically examining existing stability constant data

  5. The ionising radiation effect on physico-chemical properties of organosilicon oils

    International Nuclear Information System (INIS)

    Krasnopyorova, A.P.

    1998-01-01

    The physico-chemical characteristics of organosilicon oils, as dielectric constant, viscosity, and refractive index, have been measured before and after the gamma irradiation with the doses of 10 3 to 10 6 Gray. The organosilicons studied were PMS-1, PMS-5, PMS-VV, and PMFS. All the measurements were performed with 60 Co in open test tubes as a source of gamma radiation. The structure modifications in oil molecules depending on irradiation dose have been studied with IR spectrometry. When comparing the main characteristics of the studied organosilicons before and after the irradiation one may arrange them into the following sequence with the increasing of their resistance to the gamma radiation: PMS-VV 6 GRay. For the liquids PMS-1 and PMS-VV it is found that the increasing of their viscosity with the dose absorbed obeys exponential law: ν ν 0 exp (K γ .D), where ν 0 and ν are the viscosities of the sample before and after the irradiation, respectively; D is the absorbed radiation dose; K γ is the radiation damage factor. (author)

  6. The Spatial Distribution of Alkaloids in Psychotria prunifolia (Kunth) Steyerm and Palicourea coriacea (Cham.) K. Schum Leaves Analysed by Desorption Electrospray Ionisation Mass Spectrometry Imaging

    DEFF Research Database (Denmark)

    Kato, Lucilia; Moraes, Aline Pereira; de Oliveira, Cecília Maria Alves

    2018-01-01

    INTRODUCTION: Species of the genera Psychotria and Palicourea are sources of indole alkaloids, however, the distribution of alkaloids within the plants is not known. Analysing the spatial distribution using desorption electrospray ionisation mass spectrometry imaging (DESI-MSI) has become...... analyses. METHODOLOGY: Based upon previous structure elucidation studies, four alkaloids targeted in this study were identified using high resolution mass spectrometry by direct infusion of plant extracts, and their distributions were imaged by DESI-MSI via tissue imprints on a porous Teflon surface....... Relative quantitation of the four alkaloids was obtained by HPLC-MS/MS analysis performed using multiple-reaction monitoring (MRM) mode on a triple quadrupole mass spectrometer. RESULTS: Alkaloids showed distinct distributions on the leaf surfaces. Prunifoleine was mainly present in the midrib, while 10...

  7. End-group characterisation of poly(propylene glycol)s by means of electrospray ionisation-tandem mass spectrometry (ESI-MS/MS).

    Science.gov (United States)

    Jackson, Anthony T; Slade, Susan E; Thalassinos, Konstantinos; Scrivens, James H

    2008-10-01

    The end-group functionalisation of a series of poly(propylene glycol)s has been characterised by means of electrospray ionisation-tandem mass spectrometry (ESI-MS/MS). A series of peaks with mass-to-charge ratios that are close to that of the precursor ion were used to generate information on the end-group functionalities of the poly(propylene glycol)s. Fragment ions resulting from losses of both of the end groups were noted from some of the samples. An example is presented of how software can be used to significantly reduce the length of time involved in data interpretation (which is typically the most time-consuming part of the analysis).

  8. Time-resolved analysis of the emission of sidestream smoke (SSS) from cigarettes during smoking by photo ionisation/time-of-flight mass spectrometry (PI-TOFMS): towards a better description of environmental tobacco smoke.

    Science.gov (United States)

    Streibel, T; Mitschke, S; Adam, T; Zimmermann, R

    2013-09-01

    In this study, the chemical composition of sidestream smoke (SSS) emissions of cigarettes are characterised using a laser-based single-photon ionisation time-of-flight mass spectrometer. SSS is generated from various cigarette types (2R4F research cigarette; Burley, Oriental and Virginia single-tobacco-type cigarettes) smoked on a single-port smoking machine and collected using a so-called fishtail chimney device. Using this setup, a puff-resolved quantification of several SSS components was performed. Investigations of the dynamics of SSS emissions show that concentration profiles of various substances can be categorised into several groups, either depending on the occurrence of a puff or uninfluenced by the changes in the burning zone during puffing. The SSS emissions occurring directly after a puff strongly resemble the composition of mainstream smoke (MSS). In the smouldering phase, clear differences between MSS and SSS are observed. The changed chemical profiles of SSS and MSS might be also of importance on environmental tobacco smoke which is largely determined by SSS. Additionally, the chemical composition of the SSS is strongly affected by the tobacco type. Hence, the higher nitrogen content of Burley tobacco leads to the detection of increased amounts of nitrogen-containing substances in SSS.

  9. Identification of monohydroxy progesterones produced by CYP106A2 using comparative HPLC and electrospray ionisation collision-induced dissociation mass spectrometry

    International Nuclear Information System (INIS)

    Lisurek, Michael; Kang, M.-J.; Hartmann, Rolf W.; Bernhardt, Rita

    2004-01-01

    Two previously uncharacterised products, produced by recombinant CYP106A2 of Bacillus megaterium ATCC 13368 using progesterone as substrate, were identified. For this purpose a combination of comparative HPLC and electrospray ionisation collision induced dissociation mass spectrometry (ESI CID MS) was established and applied for rapid identification of the steroids, which were identified as 11α-hydroxyprogesterone and 9α-hydroxyprogesterone. The pharmaceutical relevance of these steroids is discussed. Furthermore, the hydroxylation activity was quantified for all monohydroxylation products (15β-hydroxyprogesterone, 6β-hydroxyprogesterone, 11α-hydroxyprogesterone, and 9α-hydroxyprogesterone). The V max values for 15β-hydroxyprogesterone, 6β-hydroxyprogesterone, 11α-hydroxyprogesterone, and 9α-hydroxyprogesterone were determined as 337.3 ± 43.7, 22.3 ± 0.9, 17.5 ± 0.9, and 6.5 ± 0.3 nmol product/min/nmol CYP106A2, respectively

  10. Identification of wheat varieties using matrix-assisted laserdesorption/ionisation time-of-flight mass spectrometry and anartificial neural network

    DEFF Research Database (Denmark)

    Bloch, Helle Aagaard; Kesmir, Can; Petersen, Marianne Kjerstine

    1999-01-01

    of this novelmethod with respect to various experimental parameters has been tested. The results can be summarised: (i)With this approach 97% of the wheat varieties can be classified correctly with a corresponding correlationcoefficient of 1.0, (ii) The method is fast since the time of extracting gliadins from flour......A novel tool for variety identification of wheat (Triticum aestivum L.) has been developed: an artificialneural network (ANN) is used to classify the gliadin fraction analysed by matrix-assisted laserdesorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS). The robustness...... by the identity of the operator making theanalysis. This study demonstrates that a combination of an ANN and MALDI-TOFMS analysis of thegliadin fraction provides a fast and reliable tool for the variety identification of wheat. Copyright 1999 JohnWiley & Sons, Ltd....

  11. Rapid Identification of Steroidal Saponins in Trillium tschonoskii Maxim by Ultraperformance Liquid Chromatography Coupled to Electrospray Ionisation Quadrupole Time-of-Flight Tandem Mass Spectrometry.

    Science.gov (United States)

    Gao, Xin; Sun, Wenjun; Fu, Qiang; Niu, Xiaofeng

    2015-01-01

    Steroidal saponins in Trillium tschonoskii Maxim have many biological activities, including immunological regulation and anti-tumour. Comprehensive ingredient identification is critical for understanding its pharmacological mechanism and establishing quality control protocols. However, it is a challenging problem because of the complexity of steroidal saponins. To develop a UPLC-MS method for identifying and characterising steroidal saponins in the root and rhizome of T. tschonoskii. Methanolic extracts of T. tschonoskii were analysed by using ultraperformance liquid chromatography coupled to electrospray ionisation quadrupole time-of-flight tandem mass spectrometry (UPLC-ESI/QTOF/MS). The UPLC experiments were performed by means of a reversed-phase C18 -column and a binary mobile phase system consisting of water and acetonitrile with formic acid under gradient elution conditions. For the UPLC-MS measurements, positive and negative ion modes were used in order to obtain better tandem mass spectra and high-resolution mass spectra. Based on retention times, accurate mass and mass spectrometric fragmentation, a total of 31 saponins distributed over eight steroidal aglycone skeletons were identified or tentatively elucidated from T. tschonoskii. The UPLC-ESI/QTOF/MS method has proven to be a powerful tool for rapid identification of steroidal saponins in T. tschonoskii without tedious and time-consuming isolation of pure constituents. Copyright © 2015 John Wiley & Sons, Ltd.

  12. Atmospheric ionisation in Snowdonia

    Energy Technology Data Exchange (ETDEWEB)

    Aplin, K L [Department of Physics, University of Oxford, Denys Wilkinson Building, Keble Road, Oxford OX1 3RH UK (United Kingdom); Williams, J H, E-mail: k.aplin1@physics.ox.ac.uk [Envirodata-Eyri, Bryn Goleu, Penmaen Park, Llanfairfechan, Gwynedd LL33 0RL (United Kingdom)

    2011-06-23

    Atmospheric ionisation from natural radioactivity and cosmic rays has been measured at several sites in Snowdonia from 2005-present. The motivation for this project was a combination of public engagement with science, and research into the effects of ionisation on climate. A four-component atmospheric radiometer instrument is co-located with the ionisation detectors and the data is remotely logged and displayed on the Web. Atmospheric ionisation from natural radioactivity varies with local geology, and the cosmic ray ionisation component is modulated by solar activity and altitude. Variations due to all these effects have been identified and are described.

  13. On-line coupling of a microelectrode array equipped poly(dimethylsiloxane) microchip with an integrated graphite electrospray emitter for electrospray ionisation mass spectrometry.

    Science.gov (United States)

    Liljegren, Gustav; Dahlin, Andreas; Zettersten, Camilla; Bergquist, Jonas; Nyholm, Leif

    2005-10-01

    A novel method for the manufacturing of microchips for on-chip combinations of electrochemistry (EC) and sheathless electrospray ionisation mass spectrometry (ESI-MS) is described. The technique, which does not require access to clean-room facilities, is based on the incorporation of an array of gold microcoil electrodes into a poly(dimethylsiloxane)(PDMS) microflow channel equipped with an integrated graphite based sheathless ESI emitter. Electrochemical measurements, which were employed to determine the electroactive area of the electrodes and to test the microchips, show that the manufacturing process was reproducible and that the important interelectrode distance in the electrochemical cell could to be adequately controlled. The EC-ESI-MS device was evaluated based on the ESI-MS detection of the oxidation products of dopamine. The results demonstrate that the present on-chip approach enables full potentiostatic control of the electrochemical cell and the attainment of very short transfer times between the electrochemical cell and the electrospray emitter. The transfer times were 0.6 and 1.2 s for flow rates of 1.0 and 0.5 microL min(-1), respectively, while the electrochemical conversion efficiency of the electrochemical cell was found to be 30% at a flow rate of 0.5 microL min(-1). To decouple the electrochemical cell from the ESI-MS high voltage and to increase the user-friendliness, the on-line electrochemistry-ESI-MS experiments were performed using a wireless Bluetooth battery-powered instrument with the chip floating at the potential induced by the ESI high voltage. The described on-chip EC-ESI-MS device can be used for fundamental electrochemical investigations as well as for applications based on the use of electrochemically controlled sample pretreatment, preconcentration and ionisation steps prior to ESI-MS.

  14. Rapid Identification of unstable acyl glucoside flavonoids of Oxytropis racemosa Turcz by high-performance liquid chromatography-diode array detection-electrospray ionisation/multi-stage mass spectrometry.

    Science.gov (United States)

    Song, Shuang; Zheng, Xiu-Ping; Liu, Wei-Dong; Du, Rui-Fang; Feng, Zi-Ming; Zhang, Pei-Cheng; Bi, Li-Fu

    2013-02-01

    Oxytropis racemosa Turcz is an important minority medicine that is used mainly to improve children's indigestion, especially in inner Mongolia and Tibet. Previous studies indicated that the characteristic constituents of this plant are acylated flavonoids. Rapidly identify the characteristic chemical constituents of O. racemosa by high-performance liquid chromatography-diode array detection-electrospray ionisation/multi-stage mass spectrometry (HPLC-DAD-ESI/MS(n) ) and suggest a useful method to control the quality of this medicinal plant. In the HPLC fingerprint, 32 flavonoids were tentatively identified by a detailed analysis of their mass spectra, UV spectra and retention times. Furthermore, 13 flavonoids were confirmed by comparison with previously isolated compounds obtained from O. racemosa. In total, 32 flavonoids, including 13 flavonoids with 3-hydroxy-3-methylglutaric acid (HMG) moieties and four flavonoids with 3-malonyl moieties, were identified in the extract of O. racemosa. Among the compounds identified, 10 were characterised as new compounds for their particular acylated sugar moieties. The method described is effective for obtaining a comprehensive phytochemical profile of plants containing unstable acylated flavonoids. The method is also useful for constructing the chromatographic fingerprint of the minority medicine -O. racemosa Turcz for quality control. Copyright © 2012 John Wiley & Sons, Ltd.

  15. Overview of programmes for the assessment of risks to the environment from ionising radiation and hazardous chemicals

    International Nuclear Information System (INIS)

    Jones, C; Gilek, M

    2004-01-01

    Within the FASSET project, a review of existing programmes for the assessment of environmental risks from radioactive or hazardous substances was carried out in order to identify appropriate aspects that could be incorporated into the FASSET framework. The review revealed a number of different approaches, arising from the need to balance the information value of the assessment against the availability of data and the need to keep the assessment manageable. Most of the existing assessment programmes fit into a three-phase approach to environmental risk assessment: problem formulation, assessment and risk characterisation. However, the emphasis on particular assessment phases varies between programmes. The main differences between the different programmes are: the degree of specificity to a particular site, the level of detail of the assessment, the point at which a comparison is made between a criterion intended to represent 'what is acceptable' and a measured or predicted quantity, the choice of end-point for the assessment and the relationship between measurement end-points and assessment end-points. The existing assessment programmes are based on a similar general structure, which is suitable for use as a basis for the FASSET framework. However, certain aspects of the assessment of exposure and effects of ionising contaminants, e.g. dosimetry, require further development before incorporation into such a framework

  16. Simultaneous determination of picogram per gram concentrations of Ba, Pb and Pb isotopes in Greenland ice by thermal ionisation mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Jimi, Salah I.; Rosman, Kevin J.R.; Candelone, Jean-Pierre; Burn, Laurie J. [Curtin University of Technology, Department of Imaging and Applied Physics, Perth (Australia); Hong, Sungmin [Polar Research Centre, Korean Ocean Research and Development Institute, Ansan, P.O. Box 29, Seoul (Korea); Boutron, Claude F. [Domaine Universitaire, Laboratoire de Glaciologie et Geophysique du l' Environnement, 54 rue Moliere, Saint Martin d' Heres (France); UFR de Mecanique, Universite Joseph Fourier de Grenoble (Institut Universitaire de France), Domaine Universitaire, Grenoble (France)

    2008-01-15

    A technique has been developed to simultaneously measure picogram per gram concentrations of Ba and Pb by isotope dilution mass spectrometry, as well as Pb isotopic ratios in polar ice by thermal ionisation mass spectrometry. BaPO{sup +}{sub 2} and Pb{sup +} ions were employed for these determinations. A calibrated mixture of enriched {sup 205}Pb and {sup 137}Ba was added to the samples providing an accuracy of better than approximately 2% for Pb/Ba element ratio determinations. Interference by molecular ions in the Pb mass spectrum occurred only at {sup 204}Pb and {sup 205}Pb, but these contributions were negligible in terms of precisions expected on picogram-sized Pb samples. The technique is illustrated with measurements on Greenland firn, using a drill-core section that includes the Laki volcanic eruption of 1783-1784. The data show deviations from the element concentrations indicating volatile metal enrichments, but the Pb isotopic signature of the Laki lava could not be identified. (orig.)

  17. Evaluation of electro-spray ionisation mass spectrometry as a technique for the investigation of competitive interactions: A case study of the ternary Th-Mn-EDTA system

    International Nuclear Information System (INIS)

    Reinoso-Maset, Estela; Worsfold, Paul J.; Keith-Roach, Miranda J.

    2012-01-01

    Rationale: Electro-spray ionisation mass spectrometry (ESI-MS) is a useful tool for exploring the speciation of solution-phase metal complexes; however, the quantification of ternary systems is challenging due to the differences in the electro-spray response of different species. Here, the Th-Mn-EDTA system was investigated to evaluate the capability of ESI-MS for quantifying the species present. Methods: Increasingly complex mixtures of Th(IV), Mn(II) and EDTA were analysed using manual flow injection of samples into an HPLC grade water mobile phase delivered to an ion trap mass spectrometer fitted with an ESI interface (ThermoQuest Finnigan Mat LCQ). Mass spectra were obtained in the positive and negative ion modes over a mass-to-charge (m/z) range from 50-2000. Results: The instrumental response to EDTA was affected by the addition of Th(NO 3 ) 4 but not MnCl 2 , while the response to both Th-EDTA and Mn-EDTA species was affected by addition of the other metal salt. Internal standards were also found to suppress signals to different extents. Therefore, each signal suppression was carefully quantified as the solution became more complex, and signal correction factors were used in conjunction with regular external calibration. Mixed metal signals were quantified adequately. Conclusions: This study showed the complexity of quantifying a ternary system involving different co-existing species. Nonetheless, the step-wise protocol developed provided quantitative data on the displacement of Mn from its EDTA complex by Th. (authors)

  18. An intercomparison experiment on isotope dilution thermal ionisation mass spectrometry using plutonium-239 spike for the determination of plutonium concentration in dissolver solution of irradiated fuel

    International Nuclear Information System (INIS)

    Aggarwal, S.K.; Shah, P.M.; Saxena, M.K.; Jain, H.C.; Gurba, P.B.; Babbar, R.K.; Udagatti, S.V.; Moorthy, A.D.; Singh, R.K.; Bajpai, D.D.

    1996-01-01

    Determination of plutonium concentration in the dissolver solution of irradiated fuel is one of the key measurements in the nuclear fuel cycle. This report presents the results of an intercomparison experiment performed between Fuel Chemistry Division (FCD) at BARC and PREFRE, Tarapur for determining plutonium concentration in dissolver solution of irradiated fuel using 239 Pu spike in isotope dilution thermal ionisation mass spectrometry (ID-TIMS). The 239 Pu spike method was previously established at FCD as viable alternative to the imported enriched 242 Pu or 244 Pu; the spike used internationally for plutonium concentration determination by IDMS in dissolver solution of irradiated fuel. Precision and accuracy achievable for determining plutonium concentration are compared under the laboratory and the plant conditions using 239 Pu spike in IDMS. For this purpose, two different dissolver solutions with 240 Pu/ 239 Pu atom ratios of about 0.3 and 0.07 corresponding, respectively, to high and low burn-up fuels, were used. The results of the intercomparison experiment demonstrate that there is no difference in the precision values obtained under the laboratory and the plant conditions; with mean precision values of better than 0.2%. Further, the plutonium concentration values determined by the two laboratories agreed within 0.3%. This exercise, therefore, demonstrates that ID-TIMS method using 239 Pu spike can be used for determining plutonium concentration in dissolver solution of irradiated fuel, under the plant conditions. 7 refs., 8 tabs

  19. Feasibility of matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) networking in university hospitals in Brussels.

    Science.gov (United States)

    Martiny, D; Cremagnani, P; Gaillard, A; Miendje Deyi, V Y; Mascart, G; Ebraert, A; Attalibi, S; Dediste, A; Vandenberg, O

    2014-05-01

    The mutualisation of analytical platforms might be used to address rising healthcare costs. Our study aimed to evaluate the feasibility of networking a unique matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) system for common use in several university hospitals in Brussels, Belgium. During a one-month period, 1,055 successive bacterial isolates from the Brugmann University Hospital were identified on-site using conventional techniques; these same isolates were also identified using a MALDI-TOF MS system at the Porte de Hal Laboratory by sending target plates and identification projects via transportation and the INFECTIO_MALDI software (Infopartner, Nancy, France), respectively. The occurrence of transmission problems (MS networking always provided a faster identification result than conventional techniques, except when chromogenic culture media and oxidase tests were used (p MS networking could lead to substantial annual cost savings. MALDI-TOF MS networking presents many advantages, and few conventional techniques (optochin and oxidase tests) are required to ensure the same quality in patient care from the distant laboratory. Nevertheless, such networking should not be considered unless there is a reorganisation of workflow, efficient communication between teams, qualified technologists and a reliable IT department and helpdesk to manage potential connectivity problems.

  20. Use of matrix assisted laser desorption ionisation-time of flight mass spectrometry in a paediatric clinical laboratory for identification of bacteria commonly isolated from cystic fibrosis patients.

    Science.gov (United States)

    Desai, Ankita Patel; Stanley, Theresa; Atuan, Maria; McKey, Jonelle; Lipuma, John J; Rogers, Beverly; Jerris, Robert

    2012-09-01

    Matrix-assisted laser desorption ionisation-time of flight mass spectrometry (MALDI-TOF MS) has been described as a rapid, accurate method for bacterial identification. To investigate the ability of the technique, using the unamended database supplied with the system, to identify bacteria commonly isolated in cystic fibrosis (CF) patients. Organisms commonly isolated from CF patients identified by MALDI-TOF MS were compared to conventional phenotypic and genotypic analyses. For MALDI-TOF MS, the direct colony technique was used routinely with one extraction procedure performed on a mucoid Pseudomonas aeruginosa. For 24 unique CF specimens, workload comparison and time to identification were assessed. Of 464 tested isolates, conventional (phenotypic and genotypic) identification compared to MALDI-TOF MS showed complete genus, species agreement in 92%, with genus agreement in 98%. This included 29 isolates within the Burkholderia cepacia complex. All 29 were correctly identified to the genus level and 24 of these were speciated. Time to identification with 47 bacterial isolates from 24 CF patients showed identification of 85% of isolates by MALDI-TOF MS at 48 h of incubation, compared to only 34% with conventional methods. Using the unamended database supplied with the system, MALDI-TOF MS provides rapid and reliable identification of bacteria isolated from CF specimens. Time to identification studies showed that the use of same day, same method for organism identification will decrease time to result and optimise microbiology workflow.

  1. Matrix-assisted laser desorption ionisation time-of-flight mass spectrometry rapid detection of carbapenamase activity in Acinetobacter baumannii isolates

    Directory of Open Access Journals (Sweden)

    Noha Abouseada

    2017-01-01

    Full Text Available Introduction: Carbapenamase-producing Acinetobacter baumannii are an increasing threat in hospitals and Intensive Care Units. Accurate and rapid detection of carbapenamase producers has a great impact on patient improvement and aids in implementation of infection control measures. Aim: In this study, we describe the use of matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI TOF MS to identify carbapenamase-producing A. baumannii isolates in up to 3 h. Isolates and Methods: A total of 50 A. baumannii isolates (of which 39 were carabapenamase producers were tested using MALDI TOF MS. Isolates were incubated for 3 h with 0.25 mg/ml up to 2 mg/ml of imipenem (IMP at 37°C. Supernatants were analysed by MALDI TOF to analyse peaks corresponding to IMP (300 Da and an IMP metabolite (254 Da using UltrafleXtreme (Bruker Daltonics, Bremen, Germany. Results: All carbapenamase-producing isolates were evidenced by the disappearance or reduction in intensity of the 300 Da peak of IPM and the appearance of a 254 Da peak of the IPM metabolite. In isolates that did not produce carbapenamase, the IPM 300 Da peak remained intact. Conclusion: MALDI TOF is a promising tool in the field of diagnostic microbiology that has the ability to transfer identification and antimicrobial susceptibility testing time from days to hours.

  2. The detection of iron protoporphyrin (heme b) in phytoplankton and marine particulate material by electrospray ionisation mass spectrometry – comparison with diode array detection

    Energy Technology Data Exchange (ETDEWEB)

    Gledhill, Martha, E-mail: m.gledhill@geomar.de

    2014-09-02

    Highlights: • Mass spectrometry was applied to the analysis of heme b in biological material. • Optimal conditions involved selective reactant monitoring of the heme b product ion. • The isotopic signature for this iron tetrapyrrole further improved selectivity. • Mass spectrometry and spectrophotometry were compared for heme b analysis. • Combining techniques made a powerful tool for analysis of heme in marine microbes. - Abstract: A mass spectrometric (MS) method for the identification of iron protoporphyrin (IX) (FePTP, heme b) in marine particulate material and phytoplankton is described. Electrospray ionisation of FePTP produced the molecular Fe(III)PTP{sup +} ion (m/z = 616) or the pseudomolecular [Fe(II)PTP + H]{sup +} ion (m/z = 617), depending on the oxidation state of the central iron ion. Collision induced dissociation (CID) in the ion trap mass spectrometer resulted in a single detected product ion (m/z = 557) indicative of loss of ethanoic acid from a carboxylic acid side chain. Widening the isolation width to 616 ± 3 resulted in production of a mass spectrum demonstrating the distinctive isotopic ratio of the iron containing fragment, further increasing the specificity of the analysis. Selective reactant monitoring (SRM) of the fragment ion (m/z = 557) was applied to the detection of FePTP after chromatography of ammoniacal OGP extracts of marine samples. The detection limit for FePTP analysed by SRM after chromatography was 1.2 ± 0.5 fmol. For phytoplankton samples, reasonably good agreement was achieved between results obtained with SRM and those obtained by monitoring absorbance at λ = 400 nm using a diode array detector (DAD). Use of SRM for analysis of particulate material obtained from the high latitude North Atlantic allowed for the analysis of FePTP in the presence of a co-eluting compound that interfered with detection by DAD. Simultaneous collection of mass spectra from m/z = 300 to 1500 resulted in identification of the

  3. Characterisation of botulinum toxins type A and B, by matrix-assisted laser desorption ionisation and electrospray mass spectrometry

    NARCIS (Netherlands)

    Baar, B.L.M. van; Hulst, A.G.; Jong, A.L. de; Wils, E.R.J.

    2002-01-01

    A method earlier developed for the mass spectrometric (MS) identification of tetanus toxin (TTx) was applied to botulinum toxins type A and B (BTxA and BTxB). Botulinum toxins are extremely neurotoxic bacterial toxins, likely to be used as biological warfare agent. Biologically active BTxA and BTxB

  4. An investigation of the interactions of low doses of ionising radiation and chemical pollutants on Artemia Salina

    International Nuclear Information System (INIS)

    Danova, D.; Benova, K.; Hromada, R.; Falis, M.; Dvorak, P.

    2004-01-01

    Nuclear reactor failures present a risk of global contamination which can be affected by other environmental factors, such as chemicals. The present study has investigated the effect of low doses of gamma radiation in relation to the presence of low doses of Cr and Cd. (authors)

  5. Fast monitoring of motor exhaust components by resonant multi-photon ionisation and time-of-flight mass spectrometry

    Science.gov (United States)

    Franzen, Jochen; Frey, Rüdiger; Nagel, Holger

    1995-03-01

    A new analytical procedure is provided by the combination of two types of spectroscopy. Resonant ionization of selected compounds by multiphoton ionization is based on results of absorption spectroscopy for the compound molecules of interest and time-of-flight mass spectrometry serves for the unambigious detection of these compounds. An interesting application of this method is the fast exhaust gas analysis. In the development of future combustion engines, the management of dynamic motor processes becomes predominant because by more than 90 % of all the dangerous exhaust pollutions are produced in instationary motor phases such as fast speed or load changes. The investigation of dynamic processes however, requires fast analytical procedures with millisecond time resolution together with the capability to measure individual components in a very complex gas mixture The objectives for a development project of such an instrument were set by the Research Association for Combustion Engines (Forschungsvereinigung Verbrennungskraftmaschinen, FVV, Germany): Up to ten substances should be monitored synchroneously with a time resolution of about 10 milliseconds, with concentration limits of 1 part per million and with a precision better than 10 % relative standard deviation. Such a laser mass spectrometer for fast multi-component automotive exhaust analyses has been developed in a joint research project by Bruker-Franzen Analytik GmbH, Dornier GmbH and the Technical University of Munich. The system has been applied at a motor test facility to investigate the emissions of the aromatic hydrocarbons benzene, toluene and xylene, of nitric oxide and acetaldehyde in stationary and dynamic engine operation. These measurements demonstrate that strong emission of these pollutants takes place at instationary engine operation and in particular that these compounds are emitted at different times, giving new information about the processes in the combustion chamber and in the exhaust pipe.

  6. Identification of prenylated pterocarpans and other isoflavonoids in Rhizopus spp. elicited soya bean seedlings by electrospray ionisation mass spectrometry.

    Science.gov (United States)

    Simons, Rudy; Vincken, Jean-Paul; Bohin, Maxime C; Kuijpers, Tomas F M; Verbruggen, Marian A; Gruppen, Harry

    2011-01-15

    Phytoalexins from soya are mainly characterised as prenylated pterocarpans, the glyceollins. Extracts of non-soaked and soaked soya beans, as well as that of soya seedlings, grown in the presence of Rhizopus microsporus var. oryzae, were screened for the presence of prenylated flavonoids with a liquid chromatography/mass spectrometry (LC/MS)-based screening method. The glyceollins I-III and glyceollidins I-II, belonging to the isoflavonoid subclass of the pterocarpans, were tentatively assigned. The formation of these prenylated pterocarpans was accompanied by that of other prenylated isoflavonoids of the subclasses of the isoflavones and the coumestans. It was estimated that approx. 40% of the total isoflavonoid content in Rhizopus-challenged soya bean seedlings were prenylated pterocarpans, whereas 7% comprised prenylated isoflavones and prenylated coumestans. The site of prenylation (A-ring or B-ring) of the prenylated isoflavones was tentatively annotated using positive-ion mode MS by comparing the (1,3) A(+) retro-Diels-Alder (RDA) fragments of prenylated and non-prenylated isoflavones. Furthermore, the fragmentation pathways of the five pterocarpans in negative-ion (NI) mode were proposed, which involved the cleavage of the C-ring and/or D-ring. The absence of the ring-closed prenyl (pyran or furan) gave exclusively -H(2) O(x,y) RDA fragments, whereas its presence gave predominantly the common RDA fragments. Copyright © 2010 John Wiley & Sons, Ltd.

  7. Identification of organic pigments in tattoo inks and permanent make-up using laser desorption ionisation mass spectrometry [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Markus Niederer

    2018-01-01

    Full Text Available Nowadays, about 12% of the European and 20% of the US population are tattooed. Rising concerns regarding consumer safety, led to legal restrictions on tattoo and permanent make-up (PMU inks. Restrictions also include bans on certain colourants. Both ink types use organic pigments for colour-giving, plus inorganic pigments for white and black and colour tones. Pigments are only sparingly soluble in common solvents and occur as suspended particles in the ink matrix. Their detection and identification therefore pose a major challenge for laboratories involved in monitoring the legal compliance of tattoo inks and PMU. We overcame this challenge by developing a direct laser desorption ionisation time-of-flight mass spectrometry method, which included an easy sample clean up. The method proved to be capable of detecting and identifying organic pigments in almost all of the tested ink samples. Method validation and routine deployment during market surveys showed the method to be fit for purpose. Pigment screening of 396 tattoo inks and 55 PMU taken from the Swiss market between 2009 and 2017 lead to the following conclusions: Pigment variety is much greater in tattoo inks (18 than in PMU (10; four prohibited pigments (Pigment Green 7, Pigment Red 122, Pigment Violet 19 and 23 were found in both ink types; for PMU, these four pigments made up 12% of the pigment findings, compared to 32% for tattoo inks. Therefore, legal compliance of PMU was at a higher level. A comparison of pigments found with those declared on tattoo ink labels clearly showed that banned pigments are rarely declared, but rather masked by listing non present legal pigments and label forging; therefore, highlighting the urgency of widespread market controls.

  8. Direct identification of bacteria from charcoal-containing blood culture bottles using matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry.

    Science.gov (United States)

    Wüppenhorst, N; Consoir, C; Lörch, D; Schneider, C

    2012-10-01

    Several protocols for direct matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) from positive blood cultures are currently used to speed up the diagnostic process of bacteraemia. Identification rates are high and results are accurate for the BACTEC™ system and for charcoal-free bottles. Only a few studies have evaluated protocols for charcoal-containing BacT/ALERT bottles reaching substantially lower identification rates. We established a new protocol for sample preparation from aerobic and anaerobic positive charcoal-containing BacT/ALERT blood culture bottles and measured the protein profiles (n = 167). Then, we integrated this protocol in the routine workflow of our laboratory (n = 212). During the establishment of our protocol, 74.3 % of bacteria were correctly identified to the species level, in 23.4 %, no result and in 2.4 %, a false identification were obtained. Reliable criteria for correct species identification were a score value ≥1.400 and a best match on rank 1-3 of the same species. Identification rates during routine workflow were 77.8 % for correct identification, 20.8 % for not identified samples and 1.4 % for discordant identification. In conclusion, our results indicate that MALDI-TOF MS is possible, even from charcoal-containing blood cultures. Reliable criteria for correct species identification are a score value ≥1.400 and a best match on rank 1-3 of a single species.

  9. Direct identification of bacteria in positive blood culture bottles by matrix-assisted laser desorption ionisation time-of-flight mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Bernard La Scola

    Full Text Available BACKGROUND: With long delays observed between sampling and availability of results, the usefulness of blood cultures in the context of emergency infectious diseases has recently been questioned. Among methods that allow quicker bacterial identification from growing colonies, matrix-assisted laser desorption ionisation time-of-flight (MALDI-TOF mass spectrometry was demonstrated to accurately identify bacteria routinely isolated in a clinical biology laboratory. In order to speed up the identification process, in the present work we attempted bacterial identification directly from blood culture bottles detected positive by the automate. METHODOLOGY/PRINCIPAL FINDINGS: We prospectively analysed routine MALDI-TOF identification of bacteria detected in blood culture by two different protocols involving successive centrifugations and then lysis by trifluoroacetic acid or formic acid. Of the 562 blood culture broths detected as positive by the automate and containing one bacterial species, 370 (66% were correctly identified. Changing the protocol from trifluoroacetic acid to formic acid improved identification of Staphylococci, and overall correct identification increased from 59% to 76%. Lack of identification was observed mostly with viridans streptococci, and only one false positive was observed. In the 22 positive blood culture broths that contained two or more different species, only one of the species was identified in 18 samples, no species were identified in two samples and false species identifications were obtained in two cases. The positive predictive value of bacterial identification using this procedure was 99.2%. CONCLUSIONS/SIGNIFICANCE: MALDI-TOF MS is an efficient method for direct routine identification of bacterial isolates in blood culture, with the exception of polymicrobial samples and viridans streptococci. It may replace routine identification performed on colonies, provided improvement for the specificity of blood culture

  10. Direct identification of bacteria in positive blood culture bottles by matrix-assisted laser desorption ionisation time-of-flight mass spectrometry.

    Science.gov (United States)

    La Scola, Bernard; Raoult, Didier

    2009-11-25

    With long delays observed between sampling and availability of results, the usefulness of blood cultures in the context of emergency infectious diseases has recently been questioned. Among methods that allow quicker bacterial identification from growing colonies, matrix-assisted laser desorption ionisation time-of-flight (MALDI-TOF) mass spectrometry was demonstrated to accurately identify bacteria routinely isolated in a clinical biology laboratory. In order to speed up the identification process, in the present work we attempted bacterial identification directly from blood culture bottles detected positive by the automate. We prospectively analysed routine MALDI-TOF identification of bacteria detected in blood culture by two different protocols involving successive centrifugations and then lysis by trifluoroacetic acid or formic acid. Of the 562 blood culture broths detected as positive by the automate and containing one bacterial species, 370 (66%) were correctly identified. Changing the protocol from trifluoroacetic acid to formic acid improved identification of Staphylococci, and overall correct identification increased from 59% to 76%. Lack of identification was observed mostly with viridans streptococci, and only one false positive was observed. In the 22 positive blood culture broths that contained two or more different species, only one of the species was identified in 18 samples, no species were identified in two samples and false species identifications were obtained in two cases. The positive predictive value of bacterial identification using this procedure was 99.2%. MALDI-TOF MS is an efficient method for direct routine identification of bacterial isolates in blood culture, with the exception of polymicrobial samples and viridans streptococci. It may replace routine identification performed on colonies, provided improvement for the specificity of blood culture broths growing viridans streptococci is obtained in the near future.

  11. Diagnostic performance of matrix-assisted laser desorption ionisation time-of-flight mass spectrometry in blood bacterial infections: a systematic review and meta-analysis.

    Science.gov (United States)

    Scott, Jamie S; Sterling, Sarah A; To, Harrison; Seals, Samantha R; Jones, Alan E

    2016-07-01

    Matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-TOF MS) has shown promise in decreasing time to identification of causative organisms compared to traditional methods; however, the utility of MALDI-TOF MS in a heterogeneous clinical setting is uncertain. To perform a systematic review on the operational performance of the Bruker MALDI-TOF MS system and evaluate published cut-off values compared to traditional blood cultures. A comprehensive literature search was performed. Studies were included if they performed direct MALDI-TOF MS analysis of blood culture specimens in human patients with suspected bacterial infections using the Bruker Biotyper software. Sensitivities and specificities of the combined studies were estimated using a hierarchical random effects linear model (REML) incorporating cut-off scores of ≥1.7 and ≥2.0. Fifty publications were identified, with 11 studies included after final review. The estimated sensitivity utilising a cut-off of ≥2.0 from the combined studies was 74.6% (95% CI = 67.9-89.3%), with an estimated specificity of 88.0% (95% CI = 74.8-94.7%). When assessing a cut-off of ≥1.7, the combined sensitivity increases to 92.8% (95% CI = 87.4-96.0%), but the estimated specificity decreased to 81.2% (95% CI = 61.9-96.6%). In this analysis, MALDI-TOF MS showed acceptable sensitivity and specificity in bacterial speciation with the current recommended cut-off point compared to blood cultures; however, lowering the cut-off point from ≥2.0 to ≥1.7 would increase the sensitivity of the test without significant detrimental effect on the specificity, which could improve clinician confidence in their results.

  12. Investigation of pyrrolizidine alkaloids including their respective N-oxides in selected food products available in Hong Kong by liquid chromatography electrospray ionisation mass spectrometry.

    Science.gov (United States)

    Chung, Stephen W C; Lam, Aaron C H

    2017-07-01

    This study determined the levels of pyrrolizidine alkaloids (PAs), including their respective N-oxides, in foodstuffs available in Hong Kong by liquid chromatography-electrospray ionisation tandem mass spectrometry. A total of 234 samples (48 food items) were collected randomly from a local market and analysed. About 50% of samples were found to contain detectable amount of PAs. Amongst the 48 food items, PAs were not detected in 11 food items, including barley flour, beef, cattle liver, pork, pig liver, chicken meat, chicken liver, milk, non-fermented tea, Melissa tea and linden tea. For those found to contain detectable PAs, the summed PA content ranged up to 11,000 µg kg -1 . The highest sum of PA content among the 37 food items calculated with lower bound was cumin seed, then followed by oregano, tarragon and herbs de Provence with ranges of 2.5-11,000, 1.5-5100, 8.0-3300 and 18-1300 µg kg -1 respectively. Among the samples, the highest sum of PA content was detected in a cumin seed sample (11,000 µg kg -1 ), followed by an oregano (5100 µg kg -1 ), a tarragon (3300 µg kg -1 ) and a herbs de Provence (1300 µg kg -1 ). In general, the results of this study agreed well with other published results in peer-reviewed journals, except that the total PAs in honey and specific tea infusion in this study were comparatively lower.

  13. Simultaneous determination of volatile and non-volatile nitrosamines in processed meat products by liquid chromatography tandem mass spectrometry using atmospheric pressure chemical ionisation and electrospray ionisation

    DEFF Research Database (Denmark)

    Herrmann, Susan Strange; Duedahl-Olesen, Lene; Granby, Kit

    2014-01-01

    , it was only possible to ionize N-nitroso-thiazolidine-4-carboxylic acid (NTCA) and N-nitroso-2-methyl-thiazolidine-4-carboxylic acid (NMTCA) by ESI. The validated method was applied for the analysis of processed meat products and contents of N-nitrosodimethylamine (NDMA), N-nitrosopyrrolidine (NPYR), N...

  14. Chemically assisted laser ablation ICP mass spectrometry.

    Science.gov (United States)

    Hirata, Takafumi

    2003-01-15

    A new laser ablation technique combined with a chemical evaporation reaction has been developed for elemental ratio analysis of solid samples using an inductively coupled plasma mass spectrometer (ICPMS). Using a chemically assisted laser ablation (CIA) technique developed in this study, analytical repeatability of the elemental ratio measurement was successively improved. To evaluate the reliability of the CLA-ICPMS technique, Pb/U isotopic ratios were determined for zircon samples that have previously been analyzed by other techniques. Conventional laser ablation for Pb/U shows a serious elemental fractionation during ablation mainly due to the large difference in elemental volatility between Pb and U. In the case of Pb/U ratio measurement, a Freon R-134a gas (1,1,1,2-tetrafluoroethane) was introduced into the laser cell as a fluorination reactant. The Freon gas introduced into the laser cell reacts with the ablated sample U, and refractory U compounds are converted to a volatile U fluoride compound (UF6) under the high-temperature condition at the ablation site. This avoids the redeposition of U around the ablation pits. Although not all the U is reacted with Freon, formation of volatile UF compounds improves the transmission efficiency of U. Typical precision of the 206Pb/238U ratio measurement is 3-5% (2sigma) for NIST SRM 610 and Nancy 91500 zircon standard, and the U-Pb age data obtained here show good agreement within analytical uncertainties with the previously reported values. Since the observed Pb/U ratio for solid samples is relatively insensitive to laser power and ablation time, optimization of ablation conditions or acquisition parameters no longer needs to be performed on a sample-to-sample basis.

  15. Food preservation by ionising radiation

    International Nuclear Information System (INIS)

    Andrade, M. E.

    1996-01-01

    The process of food preservation by ionising radiation is an alternative, or a complement, to the traditional methods of heating, refrigerating, freezing or using chemical additives. The study and development of this technique has started on the beginning of the fifties but it is based on the radiation killing effect on micro-organisms discovered by the end of last century. Foodstuffs are treated in appropriate plants: isotopic facilities (gamma radiation) and accelerated electron beams produced by machines called accelerators. The FAO and WHO in close cooperation with the IAEA have played an important role on the development of the process and on the increment of the industrial application of food irradiation. Over the world there are about 37 countries trading foods treated by ionising radiation. However, governments have been slow to clear the utilization of this process. The main reason of this attitude is in general due to the fact that the advantages of the technique are not clearly understood. Therefore, the dissemination of the information could on one hand clarify who has to take decisions and on the other hand support the choice of those foods by the consumers. This is the unique way to dynamize the application of this process

  16. Isotope Dilution - Thermal Ionisation Mass Spectrometric Analysis for Tin in a Fly Ash Material; Analisis de Estano en una Ceniza de Combustion mediante Espectrometria de Masas de Ionizacion Termica con Dilucion Isotopica

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, C; Fernandez, M; Quejido, A L

    2006-07-01

    Isotope dilution-thermal ionisation mass spectrometry (ID-TIMS) analysis has been applied to the determination of tin in a fly ash sample supplied by the EC Joint Research Centre (Ispra, Italy). The proposed procedure includes the silica gel/phosphoric acid technique for tin thermal ionisation activation and a strict heating protocol for isotope ratio measurements. Instrumental mass discrimination factor has been previously determined measuring a natural tin standard solution. Spike solutions has been prepared from 112Sn-enriched metal and quantified by reverse isotope dilution analysis. Two sample aliquots were spiked and tin was extracted with 4,5 M HCI during 25 min ultrasound exposure time. Due to the complex matrix of this fly ash material, a two-step purification stage using ion-exchange chromatography was required prior TIMS analysis. Obtained results for the two sample-spike blends (10,10 + - 0,55 y 10,50 + - 0,64 imolg-1) are comprarable, both value and uncertainty. Also a good reproducibility is observed between measurements. The proposed ID-TIMS procedure, as a primary method and due to the lack of fly ash reference material certified for tin content, can be used to validate more routine methodologies applied to tin determination in this kind of materials. (Author) 75 refs.

  17. Laser ablation synthesis of new gold phosphides using red phosphorus and nanogold as precursors. Laser desorption ionisation time-of-flight mass spectrometry.

    Science.gov (United States)

    Panyala, Nagender Reddy; Peña-Méndez, Eladia María; Havel, Josef

    2012-05-15

    Gold phosphides show unique optical or semiconductor properties and there are extensive high technology applications, e.g. in laser diodes, etc. In spite of the various AuP structures known, the search for new materials is wide. Laser ablation synthesis is a promising screening and synthetic method. Generation of gold phosphides via laser ablation of red phosphorus and nanogold mixtures was studied using laser desorption ionisation time-of-flight mass spectrometry (LDI TOFMS). Gold clusters Au(m)(+) (m = 1 to ~35) were observed with a difference of one gold atom and their intensities were in decreasing order with respect to m. For P(n)(+) (n = 2 to ~111) clusters, the intensities of odd-numbered phosphorus clusters are much higher than those for even-numbered phosphorus clusters. During ablation of P-nanogold mixtures, clusters Au(m)(+) (m = 1-12), P(n)(+) (n = 2-7, 9, 11, 13-33, 35-95 (odd numbers)), AuP(n)(+) (n = 1, 2-88 (even numbers)), Au(2)P(n)(+) (n = 1-7, 14-16, 21-51 (odd numbers)), Au(3)P(n)(+) (n = 1-6, 8, 9, 14), Au(4)P(n)(+) (n = 1-9, 14-16), Au(5)P(n)(+) (n = 1-6, 14, 16), Au(6)P(n)(+) (n = 1-6), Au(7)P(n)(+) (n = 1-7), Au(8)P(n)(+) (n = 1-6, 8), Au(9)P(n)(+) (n = 1-10), Au(10)P(n)(+) (n = 1-8, 15), Au(11)P(n)(+) (n = 1-6), and Au(12)P(n)(+) (n = 1, 2, 4) were detected in positive ion mode. In negative ion mode, Au(m)(-) (m = 1-5), P(n)(-) (n = 2, 3, 5-11, 13-19, 21-35, 39, 41, 47, 49, 55 (odd numbers)), AuP(n)(-) (n = 4-6, 8-26, 30-36 (even numbers), 48), Au(2)P(n)(-) (n = 2-5, 8, 11, 13, 15, 17), A(3) P(n)(-) (n = 6-11, 32), Au(4)P(n)(-) (n = 1, 2, 4, 6, 10), Au(6)P(5)(-), and Au(7)P(8)(-) clusters were observed. In both modes, phosphorus-rich Au(m)P(n) clusters prevailed. The first experimental evidence for formation of AuP(60) and gold-covered phosphorus Au(12)P(n) (n = 1, 2, 4) clusters is given. The new gold phosphides generated might inspire synthesis of

  18. Pre-electrospray ionisation manifold methylation and post-electrospray ionisation manifold cleavage/ion cluster formation observed during electrospray ionisation of chloramphenicol in solutions of methanol and acetonitrile for liquid chromatography-mass spectrometry employing a commercial quadrupole ion trap mass analyser.

    Science.gov (United States)

    Sichilongo, Kwenga F; Famuyiwa, Samson O; Kibechu, Rose

    2011-01-01

    We have observed unusual mass spectra of chloramphenicol (CAP) in solutions of methanol or acetonitrile showing intense ions at m/z 297, m/z 311, m/z 325 and m/z 339. The observed ions were different from those which are traditionally observed in the full scan ESI mass spectra of CAP with ions of m/z 321, m/z 323 and m/z 325. We have evidence to show that this process starts with offline methylation of CAP in solutions of methanol or acetonitrile to give m/z 339. Investigations using nuclear magnetic resonance (NMR) spectroscopy showed that there is a methylene group somewhere within the CAP molecule but not attached to any of the carbon atoms when the CAP is dissolved in methanol or acetonitrile before infusion into the mass spectrometer. The possible locations of attachment were speculated to be the electronegative atoms apart from the chlorine atoms due to valence considerations. The methylene group is attached to the nitrogen atom and forms a bond as observed in the MS/MS spectra of m/z 297, m/z 311, m/z 325 and m/z 339 which give m/z 183 as the base peak in all cases. Further experiments showed that there is cleavage of the methylated CAP molecule followed by cluster ion formation involving addition of methylene groups to the CAP fragment with m/z 183 to produce ions of m/z including m/z 297, m/z 311, m/z 325 and m/z 339. This process occurs in the mass spectrometer in the region housing the tube lens and is triggered when the ions are accelerated through this region by application of a negative tube lens offset voltage. This region affords collision of the charged droplets with a collision gas in this case nitrogen to strip the droplets of their solvent molecules. Experiments to follow the intensities of m/z 183, m/z 311, m/z 321, m/z 323, m/z 325 and m/z 339 as the tube lens offset voltage was varied were done in which the intensities of m/z 311, m/z 325 and m/z 339 were observed to be at their peak when the tube lens offset voltage was set at -40 V. When

  19. Generator for ionising radiation

    International Nuclear Information System (INIS)

    Romanovsky, V.F.; Panasjuk, V.S.; Stepanov, B.M.; Ovcharov, A.M.; Akimov, J.A.

    1979-01-01

    The generator for ionising radiation wherein a transmitter for ionising radiation contains a resonance transformer wherein the field coil is composed of a low voltage outside portion and a transformer coil, electrically connected with an electrically conducting housing of the resonance transformer, and an acclerating tube wherein the high voltage electrode is coupled with the high voltage end of the transformer coil of the resonance transformer and fixed to one of the ends of the tubular insulator of the accelerator tube, wherein the low voltage electrode is electrically connected with the housing of the resonance transformer and a source of charged particles is introduced into the evacuated inner space of the acceleration tube and electrically connected with one of the electrodes thereof, is described. (G.C.)

  20. Ionising radiation. Part 2

    International Nuclear Information System (INIS)

    2000-01-01

    A brief tutorial on the health effects of ionising radiation is presented. The distinction between somatic and genetic health effects is explained. The two types of somatic health effects, i.e., acute and chronic effects, are discussed, as well as the concepts of ''deterministic'' and ''stochastic'' (also called ''probabilistic'') health effects. The possibility of cancer caused by DNA damage is discussed. The document ends with the definition of some key radiation terms

  1. Real-time analysis of aromatics in combustion engine exhaust by resonance-enhanced multiphoton ionisation time-of-flight mass spectrometry (REMPI-TOF-MS): a robust tool for chassis dynamometer testing

    Energy Technology Data Exchange (ETDEWEB)

    Adam, T.W. [European Commission Joint Research Centre, Institute for Environment and Sustainability, Transport and Air Quality Unit, Ispra, VA (Italy); Clairotte, M.; Manfredi, U.; Carriero, M.; Martini, G.; Krasenbrink, A.; Astorga, C. [European Commission Joint Research Centre, Institute for Environment and Sustainability, Transport and Air Quality Unit, Ispra, VA (Italy); European Commission Joint Research Centre, Institute for Energy and Transport, Sustainable Transport Unit, Ispra, Varese (Italy); Streibel, T.; Pommeres, A.; Sklorz, M. [University of Rostock, Analytical Chemistry/Joint Mass Spectrometry Centre, Institute of Chemistry, Rostock (Germany); Elsasser, M.; Zimmermann, R. [Cooperation Group Complex Molecular Systems (CMA)/Joint Mass Spectrometry Centre (JMSC), Neuherberg (Germany); University of Rostock, Analytical Chemistry/Joint Mass Spectrometry Centre, Institute of Chemistry, Rostock (Germany)

    2012-07-15

    Resonance-enhanced multiphoton ionisation time-of-flight mass spectrometry (REMPI-TOF-MS) is a robust method for real-time analysis of monocyclic and polycyclic aromatic hydrocarbons in complex emissions. A mobile system has been developed which enables direct analysis on site. In this paper, we utilize a multicomponent calibration scheme based on the analytes' photo-ionisation cross-sections relative to a calibrated species. This allows semi-quantification of a great number of components by only calibrating one compound of choice, here toluene. The cross-sections were determined by injecting nebulised solutions of aromatic compounds into the TOF-MS ion source with the help of a HPLC pump. Then, REMPI-TOF-MS was implemented at various chassis dynamometers and test cells and the exhaust of the following vehicles and engines investigated: a compression ignition light-duty (LD) passenger car, a compression ignition LD van, two spark ignition LD passenger cars, 2 two-stroke mopeds, and a two-stroke engine of a string gas trimmer. The quantitative time profiles of benzene are shown. The results indicate that two-stroke engines are a significant source for toxic and cancerogenic compounds. Air pollution and health effects caused by gardening equipment might still be underestimated. (orig.)

  2. A peptidomic approach for monitoring and characterising peptide cyanotoxins produced in Italian lakes by matrix-assisted laser desorption/ionisation and quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Ferranti, Pasquale; Nasi, Antonella; Bruno, Milena; Basile, Adriana; Serpe, Luigi; Gallo, Pasquale

    2011-05-15

    In recent years, the occurrence of cyanobacterial blooms in eutrophic freshwaters has been described all over the world, including most European countries. Blooms of cyanobacteria may produce mixtures of toxic secondary metabolites, called cyanotoxins. Among these, the most studied are microcystins, a group of cyclic heptapeptides, because of their potent hepatotoxicity and activity as tumour promoters. Other peptide cyanotoxins have been described whose structure and toxicity have not been thoroughly studied. Herein we present a peptidomic approach aimed to characterise and quantify the peptide cyanotoxins produced in two Italian lakes, Averno and Albano. The procedure was based on matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry mass spectrometry (MALDI-TOF-MS) analysis for rapid detection and profiling of the peptide mixture complexity, combined with liquid chromatography/electrospray ionisation quadrupole time-of- flight tandem mass spectrometry (LC/ESI-Q-TOF-MS/MS) which provided unambiguous structural identification of the main compounds, as well as accurate quantitative analysis of microcystins. In the case of Lake Averno, a novel variant of microcystin-RR and two novel anabaenopeptin variants (Anabaenopeptins B(1) and Anabaenopeptin F(1)), presenting homoarginine in place of the commonly found arginine, were detected and characterised. In Lake Albano, the peculiar peptide patterns in different years were compared, as an example of the potentiality of the peptidomic approach for fast screening analysis, prior to fine structural analysis and determination of cyanotoxins, which included six novel aeruginosin variants. This approach allows for wide range monitoring of cyanobacteria blooms, and to collect data for evaluating possible health risks to consumers, through the panel of the compounds produced along different years. Copyright © 2011 John Wiley & Sons, Ltd.

  3. Introduction to computational mass transfer with applications to chemical engineering

    CERN Document Server

    Yu, Kuo-Tsong

    2014-01-01

    This book presents a new computational methodology called Computational Mass Transfer (CMT). It offers an approach to rigorously simulating the mass, heat and momentum transfer under turbulent flow conditions with the help of two newly published models, namely the C’2—εC’ model and the Reynolds  mass flux model, especially with regard to predictions of concentration, temperature and velocity distributions in chemical and related processes. The book will also allow readers to understand the interfacial phenomena accompanying the mass transfer process and methods for modeling the interfacial effect, such as the influences of Marangoni convection and Rayleigh convection. The CMT methodology is demonstrated by means of its applications to typical separation and chemical reaction processes and equipment, including distillation, absorption, adsorption and chemical reactors. Professor Kuo-Tsong Yu is a Member of the Chinese Academy of Sciences. Dr. Xigang Yuan is a Professor at the School of Chemical Engine...

  4. European Code against Cancer 4th Edition: Ionising and non-ionising radiation and cancer.

    Science.gov (United States)

    McColl, Neil; Auvinen, Anssi; Kesminiene, Ausrele; Espina, Carolina; Erdmann, Friederike; de Vries, Esther; Greinert, Rüdiger; Harrison, John; Schüz, Joachim

    2015-12-01

    Ionising radiation can transfer sufficient energy to ionise molecules, and this can lead to chemical changes, including DNA damage in cells. Key evidence for the carcinogenicity of ionising radiation comes from: follow-up studies of the survivors of the atomic bombings in Japan; other epidemiological studies of groups that have been exposed to radiation from medical, occupational or environmental sources; experimental animal studies; and studies of cellular responses to radiation. Considering exposure to environmental ionising radiation, inhalation of naturally occurring radon is the major source of radiation in the population - in doses orders of magnitude higher than those from nuclear power production or nuclear fallout. Indoor exposure to radon and its decay products is an important cause of lung cancer; radon may cause approximately one in ten lung cancers in Europe. Exposures to radon in buildings can be reduced via a three-step process of identifying those with potentially elevated radon levels, measuring radon levels, and reducing exposure by installation of remediation systems. In the 4th Edition of the European Code against Cancer it is therefore recommended to: "Find out if you are exposed to radiation from naturally high radon levels in your home. Take action to reduce high radon levels". Non-ionising types of radiation (those with insufficient energy to ionise molecules) - including extremely low-frequency electric and magnetic fields as well as radiofrequency electromagnetic fields - are not an established cause of cancer and are therefore not addressed in the recommendations to reduce cancer risk. Copyright © 2015 International Agency for Research on Cancer. Published by Elsevier Ltd. All rights reserved.

  5. Genetic effects of ionising radiation

    International Nuclear Information System (INIS)

    Saunders, P.

    1981-01-01

    The mutagenic effects of ionising radiation on germ cells with resulting genetic abnormalities in subsequent generations, are considered. Having examined a simple model to explain the interaction of ionising radiation with genetic material and discussed its limitations, the methods whereby mutations are transmitted are discussed. Methods of estimating genetic risks and the results of such studies are examined. (U.K.)

  6. On the network thermodynamics of mass action chemical reaction networks

    NARCIS (Netherlands)

    Schaft, A.J. van der; Rao, S.; Jayawardhana, B.

    In this paper we elaborate on the mathematical formulation of mass action chemical reaction networks as recently given in van der Schaft, Rao, Jayawardhana (2012). We show how the reference chemical potentials define a specific thermodynamical equilibrium, and we discuss the port-Hamiltonian

  7. Radiation, chemical and biological protection. Mass destruction weapons

    International Nuclear Information System (INIS)

    Janasek, D.; Svetlik, J.

    2005-01-01

    In this text-book mass destruction weapons and radiation, chemical and biological protection are reviewed. The text-book contains the following chapter: (1) Mass destruction weapons; (2) Matter and material; (3) Radioactive materials; (4) Toxic materials; (5) Biological resources; (6) Nuclear energetic equipment; Appendices; References.

  8. A Coupled Chemical and Mass Transport Model for Concrete Durability

    DEFF Research Database (Denmark)

    Jensen, Mads Mønster; Johannesson, Björn; Geiker, Mette Rica

    2012-01-01

    In this paper a general continuum theory is used to evaluate the service life of cement based materials, in terms of mass transport processes and chemical degradation of the solid matrix. The model established is a reactive mass transport model, based on an extended version of the Poisson-Nernst-...

  9. Use of ionising radiation

    International Nuclear Information System (INIS)

    1988-11-01

    The Committee has inquired into and reported on the use of ionising radiation for commercial sterilisation, disinfestation, food preservation and other purposes with particular reference to human health and safety; environmental impacts, and adequacy of assessment and regulatory procedures. While food irradiation is apparently commercially successful overseas the application to Australia seems extremely limited - it would be used primarily for disinfestation of insect pests and perhaps to reduce levels of harmful bacteria in a limited range of foods. For other applications there are effective and more economic alternatives. The report reviews other studies of food irradiation and the policies and practices governing its use in other countries. The safety of irradiated food, the radiological safety issues and the regulations which would be required in Australia are dealt with in detail. The Committee recommends, inter alia, that the Australian Government should not approve the irradiation of food in Australia until such time as a routine commercial method of detection has been developed and that the import of caesium 137 for use as an irradiation source in commercial irradiation facilities be prohibited

  10. Mass transfer with complex reversible chemical reactions—I. Single reversible chemical reaction

    NARCIS (Netherlands)

    Versteeg, G.F.; Kuipers, J.A.M.; Beckum, F.P.H. van; Swaaij, W.P.M. van

    1989-01-01

    An improved numerical technique was used in order to develop an absorption model with which it is possible to calculate rapidly absorption rates for the phenomenon of mass transfer accompanied by a complex reversible chemical reaction. This model can be applied for the calculation of the mass

  11. Mass transfer with complex reversible chemical reactions—II. parallel reversible chemical reactions

    NARCIS (Netherlands)

    Versteeg, G.F.; Kuipers, J.A.M.; Beckum, F.P.H. van; Swaaij, W.P.M. van

    1990-01-01

    An absorption model has been developed which can be used to calculate rapidly absorption rates for the phenomenon mass transfer accompanied by multiple complex parallel reversible chemical reactions. This model can be applied for the calculation of the mass transfer rates, enhancement factors and

  12. Mass transfer with complex reversible chemical reactions. II: Parallel reversible chemical reactions

    NARCIS (Netherlands)

    Versteeg, Geert; van Beckum, F.P.H.; Kuipers, J.A.M.; van Swaaij, Willibrordus Petrus Maria

    1990-01-01

    An absorption model has been developed which can be used to calculate rapidly absorption rates for the phenomenon mass transfer accompanied by multiple complex parallel reversible chemical reactions. This model can be applied for the calculation of the mass transfer rates, enhancement factors and

  13. Mass transfer with complex reversible chemical reactions. II: parallel reversible chemical reactions

    NARCIS (Netherlands)

    Versteeg, G.F.; Kuipers, J.A.M.; Beckum, van F.P.H.; van Swaaij, W.P.M.

    1990-01-01

    An absorption model has been developed which can be used to calculate rapidly absorption rates for the phenomenon mass transfer accompanied by multiple complex parallel reversible chemical reactions. This model can be applied for the calculation of the mass transfer rates, enhancement factors and

  14. Mass transfer with complex reversible chemical reactions—II. parallel reversible chemical reactions

    OpenAIRE

    Versteeg, G.F.; Kuipers, J.A.M.; Beckum, F.P.H. van; Swaaij, W.P.M. van

    1990-01-01

    An absorption model has been developed which can be used to calculate rapidly absorption rates for the phenomenon mass transfer accompanied by multiple complex parallel reversible chemical reactions. This model can be applied for the calculation of the mass transfer rates, enhancement factors and concentration profiles for a wide range of processes and conditions, for both film and penetration model. With the aid of this mass transfer model it is demonstrated that the absorption rates in syst...

  15. Mass transfer with chemical reaction in multiphase systems

    International Nuclear Information System (INIS)

    Alper, E.

    1983-01-01

    These volumes deal with the phenomenon of 'mass transfer with chemical reaction' which is of industrial, biological and physiological importance. In process engineering, it is encountered both in separation processes and in reaction engineering and both aspects are covered here in four sections: introduction; gas-liquid system; liquid-liquid system; and gas-liquid-solid system

  16. Open complex-balanced mass action chemical reaction networks

    NARCIS (Netherlands)

    Rao, Shodhan; van der Schaft, Arjan; Jayawardhana, Bayu

    We consider open chemical reaction networks, i.e. ones with inflows and outflows. We assume that all the inflows to the network are constant and all outflows obey the mass action kinetics rate law. We define a complex-balanced open reaction network as one that admits a complex-balanced steady state.

  17. A Coupled Chemical and Mass Transport Model for Concrete Durability

    DEFF Research Database (Denmark)

    Jensen, Mads Mønster; Johannesson, Björn; Geiker, Mette Rica

    2012-01-01

    -Raphson iteration scheme arising from the non-linearity. The overall model is a transient problem, solved using a single parameter formulation. The sorption hysteresis and chemical equilibrium is included as source or sink terms. The advantages with this formulation is that each node in the discrete system has...... their individual sorption hysteresis isotherm which is of great importance when describing non fully water saturated system e.g. caused by time depended boundary conditions. Chemical equilibrium is also established in each node of the discrete system, where the rate of chemical degradation is determined.......g. charge balance, from the mass transport calculation could cause the above mentioned numerical problems. Two different test cases are studied, the sorption hysteresis in different depth of the sample, caused by time depended boundary condition and the chemical degradation of the solid matrix in a ten year...

  18. Profile of phenolic compounds of Brazilian virgin olive oils by rapid resolution liquid chromatography coupled to electrospray ionisation time-of-flight mass spectrometry (RRLC-ESI-TOF-MS).

    Science.gov (United States)

    Ballus, Cristiano Augusto; Quirantes-Piné, Rosa; Bakhouche, Abdelhakim; da Silva, Luiz Fernando de Oliveira; de Oliveira, Adelson Francisco; Coutinho, Enilton Fick; da Croce, Dorli Mario; Segura-Carretero, Antonio; Godoy, Helena Teixeira

    2015-03-01

    In recent years, agronomical researchers began to cultivate several olive varieties in different regions of Brazil to produce virgin olive oil (VOO). Because there has been no reported data regarding the phenolic profile of the first Brazilian VOO, the aim of this work was to determine phenolic contents of these samples using rapid-resolution liquid chromatography coupled to electrospray ionisation time-of-flight mass spectrometry. 25 VOO samples from Arbequina, Koroneiki, Arbosana, Grappolo, Manzanilla, Coratina, Frantoio and MGS Mariense varieties from three different Brazilian states and two crops were analysed. It was possible to quantify 19 phenolic compounds belonging to different classes. The results indicated that Brazilian VOOs have high total phenolic content because the values were comparable with those from high-quality VOOs produced in other countries. VOOs from Coratina, Arbosana and Grappolo presented the highest total phenolic content. These data will be useful in the development and improvement of Brazilian VOO. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Comparative evaluation of matrix-assisted laser desorption ionisation-time of flight mass spectrometry and conventional phenotypic-based methods for identification of clinically important yeasts in a UK-based medical microbiology laboratory.

    Science.gov (United States)

    Fatania, Nita; Fraser, Mark; Savage, Mike; Hart, Jason; Abdolrasouli, Alireza

    2015-12-01

    Performance of matrix-assisted laser desorption ionisation-time of flight mass spectrometry (MALDI-TOF MS) was compared in a side-by side-analysis with conventional phenotypic methods currently in use in our laboratory for identification of yeasts in a routine diagnostic setting. A diverse collection of 200 clinically important yeasts (19 species, five genera) were identified by both methods using standard protocols. Discordant or unreliable identifications were resolved by sequencing of the internal transcribed spacer region of the rRNA gene. MALDI-TOF and conventional methods were in agreement for 182 isolates (91%) with correct identification to species level. Eighteen discordant results (9%) were due to rarely encountered species, hence the difficulty in their identification using traditional phenotypic methods. MALDI-TOF MS enabled rapid, reliable and accurate identification of clinically important yeasts in a routine diagnostic microbiology laboratory. Isolates with rare, unusual or low probability identifications should be confirmed using robust molecular methods. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. Ionisation detectors as monitors of toxic compounds in air

    International Nuclear Information System (INIS)

    Leonhardt, J.W.

    1994-01-01

    Beta particles cause ionisation in gas mixtures. The ions produced provide information on the concentration and identity of trace compounds in ambient air. Modern ionisation detectors use ion mobilities to monitor toxic compounds. Chemical solvent, phosphororganic compounds, PCB and many other toxins can be detected using ion mobility detectors (IMD) in the ppb range or lower. Ion mobility detectors have large potential in industry and research because of their sensitivity, specificity, fast response and relatively low cost. Portable devices and fixed installations are possible. The paper discusses the following topics: (1) ionisation sources in IMD: 63 Ni, 3 H, photoionization and corona discharge, (2) basic principles of ion production, (3) ion collection in IMD, (4) design, gas supply, automatic identification and quantification of IMD data, and (5) selected applications. Advantages and problems with this new type of nuclear analytical instrument are also discussed. (author). 2 refs., 9 figs., 3 tabs

  1. Efficient mining of myxobacterial metabolite profiles enabled by liquid chromatography-electrospray ionisation-time-of-flight mass spectrometry and compound-based principal component analysis

    International Nuclear Information System (INIS)

    Krug, Daniel; Zurek, Gabriela; Schneider, Birgit; Garcia, Ronald; Mueller, Rolf

    2008-01-01

    Bacteria producing secondary metabolites are an important source of natural products with highly diverse structures and biological activities. Developing methods to efficiently mine procaryotic secondary metabolomes for the presence of potentially novel natural products is therefore of considerable interest. Modern mass spectrometry-coupled liquid chromatography can effectively capture microbial metabolic diversity with ever improving sensitivity and accuracy. In addition, computational and statistical tools increasingly enable the targeted analysis and exploration of information-rich LC-MS datasets. In this article, we describe the use of such techniques for the characterization of myxobacterial secondary metabolomes. Using accurate mass data from high-resolution ESI-TOF measurements, target screening has facilitated the rapid identification of known myxobacterial metabolites in extracts from nine Myxococcus species. Furthermore, principal component analysis (PCA), implementing an advanced compound-based bucketing approach, readily revealed the presence of further compounds which contribute to variation among the metabolite profiles under investigation. The generation of molecular formulae for putative novel compounds with high confidence due to evaluation of both exact mass position and isotopic pattern, is exemplified as an important key for de-replication and prioritization of candidates for further characterization

  2. Food ionisation. Realities and perspectives

    International Nuclear Information System (INIS)

    Bonnet, G.

    1994-06-01

    The ionisation of food is a treatment using a certain type of energy. the radiations used in the industrial treatments are limited to three sources. The gamma radiations, the x radiations and the electrons beams emitted with accelerators. The physical treatments by ionizing radiations have for aim to cleanse and to increase the conservation time of food. Now, the applications in agriculture and food industry, are still marginal. The industrial using ionisation are these ones that did not find any alternative decontamination method. The barriers are more scientific or technical or economical than a question of regulation or behaviour. (N.C.)

  3. Serum amyloid beta peptides in patients with dementia and age-matched non-demented controls as detected by surface-enhanced laser desorption ionisation-time of flight mass spectrometry (SELDI-TOF MS).

    Science.gov (United States)

    Frankfort, Suzanne V; van Campen, Jos P C M; Tulner, Linda R; Beijnen, Jos H

    2008-09-01

    By using surface enhanced laser desorption/ionisation- time of flight mass spectrometry (SELDI-TOF MS) an amyloid beta (Abeta) profile was shown in cerebrospinal fluid (CSF) of patients with dementia. To investigate the Abeta-profile in serum with SELDI-TOF MS, to evaluate if this profile resembles CSF profiles and to investigate the correlation between intensity of Abeta-peptide-peaks in serum and clinical, demographical and genetic variables. Duplicate profiling of Abeta by an SELDI-TOF MS immunocapture assay was performed in 106 patients, suffering from Alzheimer's Disease or Vascular Dementia and age-matched non-demented control patients. Linear regression analyses were performed to investigate the intensities of four selected Abeta peaks as dependent variables in relation to the independent clinical, demographic or genetic variables. Abeta37, Abeta38 and Abeta40 were found among additional unidentified Abeta peptides, with the most pronounced Abeta peak at a molecular mass of 7752. This profile partly resembled the CSF profile. The clinical diagnosis was not a predictive independent variable, however ABCB1 genotypes C1236T, G2677T/A, age and creatinine level showed to be related to Abeta peak intensities in multivariate analyses. We found an Abeta profile in serum that partly resembled the CSF profile in demented patients. Age, creatinine levels, presence of the APOE epsilon4 allele and ABCB1 genotypes (C1236T and G2677T/A) were correlated with the Abeta serum profile. The role of P-gp as an Abeta transporter and the role of ABCB1 genotypes deserves further research. The investigated serum Abeta profile is probably not useful in the diagnosis of dementia.

  4. Instantaneous chemical profiles of banknotes by ambient mass spectrometry.

    Science.gov (United States)

    Eberlin, Livia S; Haddad, Renato; Sarabia Neto, Ramon C; Cosso, Ricardo G; Maia, Denison R J; Maldaner, Adriano O; Zacca, Jorge Jardim; Sanvido, Gustavo B; Romão, Wanderson; Vaz, Boniek G; Ifa, Demian R; Dill, Allison; Cooks, R Graham; Eberlin, Marcos N

    2010-10-01

    Using two desorption/ionization techniques (DESI and EASI) and Brazilian real, US$ dollar, and euro bills as proof-of-principle techniques and samples, direct analysis by ambient mass spectrometry is shown to function as an instantaneous, reproducible, and non-destructive method for chemical analysis of banknotes. Characteristic chemical profiles were observed for the authentic bills and for the counterfeit bills made using different printing processes (inkjet, laserjet, phaser and off-set printers). Detection of real-world counterfeit bills and identification of the counterfeiting method has also been demonstrated. Chemically selective 2D imaging of banknotes has also been used to confirm counterfeiting. The nature of some key diagnostic ions has also been investigated via high accuracy FTMS measurements. The general applicability of ambient MS analysis for anti-counterfeiting strategies particularly via the use of "invisible ink" markers is discussed.

  5. Recent advances in matrix-assisted laser desorption/ionisation mass spectrometry imaging (MALDI-MSI) for in situ analysis of endogenous molecules in plants.

    Science.gov (United States)

    Qin, Liang; Zhang, Yawen; Liu, Yaqin; He, Huixin; Han, Manman; Li, Yanyan; Zeng, Maomao; Wang, Xiaodong

    2018-04-17

    Mass spectrometry imaging (MSI) as a label-free and powerful imaging technique enables in situ evaluation of a tissue metabolome and/or proteome, becoming increasingly popular in the detection of plant endogenous molecules. The characterization of structure and spatial information of endogenous molecules in plants are both very important aspects to better understand the physiological mechanism of plant organism. Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) is a commonly-used tissue imaging technique, which requires matrix to assist in situ detection of a variety of molecules on the surface of a tissue section. In previous studies, MALDI-MSI was mostly used for the detection of molecules from animal tissue sections, compared to plant samples due to cell structural limitations, such as plant cuticles, epicuticular waxes, and cell walls. Despite the enormous progress that has been made in tissue imaging, there is still a challenge for MALDI-MSI suitable for the imaging of endogenous compounds in plants. This review summarises the recent advances in MALDI-MSI, focusing on the application of in situ detection of endogenous molecules in different plant organs, i.e. root, stem, leaf, flower, fruit, and seed. Further improvements on instrumentation sensitivity, matrix selection, image processing and sample preparation will expand the application of MALDI-MSI in plant research. Copyright © 2018 John Wiley & Sons, Ltd.

  6. The analysis of dyes in ball point pen inks on single paper fibres using laser desorption ionisation time of flight mass spectrometry (LDI-TOFMS).

    Science.gov (United States)

    Matthews, Broderick; Walker, G Stewart; Kobus, Hilton; Pigou, Paul; Bird, Carolyne; Smith, Glyn

    2011-06-15

    An important requisite for the forensic analysis of inks on documents is that damage to the document is avoided or minimised. This paper describes a technique for dye identification in ballpoint pen inks using LDI-TOFMS on single ink bearing paper fibres and its application to a case. A single ink bearing paper fibre can be prised from the surface of the document under a stereo microscope and presented to the instrument for analysis without further treatment. This sampling process causes imperceptible damage to the surface of the document. Clear mass spectrometric identification of the ink dyes is obtained. A case example is provided to illustrate the practical application of the technique. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  7. Oxalate Mass Balance During Chemical Cleaning in Tank 5F

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, M.; Fink, S.

    2011-07-08

    The Savannah River Site (SRS) is preparing Tank 5F for closure. The first step in preparing the tank for closure is mechanical sludge removal. Following mechanical sludge removal, SRS performed chemical cleaning with oxalic acid to remove the sludge heel. Personnel are currently assessing the effectiveness of the chemical cleaning to determine whether the tank is ready for closure. SRS personnel collected liquid samples during chemical cleaning and submitted them to Savannah River National Laboratory (SRNL) for analysis. Following chemical cleaning, they collected a solid sample (also known as 'process sample') and submitted it to SRNL for analysis. The authors analyzed these samples to assess the effectiveness of the chemical cleaning process. Analysis of the anions showed the measured oxalate removed from Tank 5F to be approximately 50% of the amount added in the oxalic acid. To close the oxalate mass balance, the author collected solid samples, leached them with nitric acid, and measured the concentration of cations and anions in the leachate.

  8. Dose limits for ionising radiation

    International Nuclear Information System (INIS)

    Gifford, D.

    1989-01-01

    Dose limits for exposure to ionising radiation are assessed to see if they give sufficient protection both for the occupationally exposed and for the general public. It is concluded that current limits give a level of safety that satisfies the necessary criteria in the light of present knowledge and further reductions would be unlikely to improve standards of safety. (author)

  9. Working safely with ionising radiation

    International Nuclear Information System (INIS)

    McDowell, D.J.

    1990-01-01

    A small leaflet provides information on working safely with ionizing radiation. Topics covered include the types of radiation, radiological units, external radiation, contamination and internal radiation, methods of protection form radiation, radiation monitors, protective clothing for contamination, personal dosemeters, radiation dose limits for classified workers and finally the Ionising Radiations Regulations 1985. (UK)

  10. Exotic highly ionising particles at the LHC

    CERN Document Server

    De Roeck, A; Mermod, P; Milstead, D; Sloan, T

    2012-01-01

    The experiments at the Large Hadron Collider (LHC) are able to discover or set limits on the production of exotic particles with TeV-scale masses possessing values of electric and/or magnetic charge such that they appear as highly ionising particles (HIPs). In this paper the sensitivity of the LHC experiments to HIP production is discussed in detail. It is shown that a number of different detection methods are required to investigate as fully as possible the charge-mass range. These include direct detection as the HIPs pass through detectors and, in the case of magnetically charged objects, the so-called induction method with which monopoles which stop in accelerator and detector material could be observed. The benefit of using complementary approaches to HIP detection is discussed.

  11. Geochemical perspectives from a new aerosol chemical mass closure

    Directory of Open Access Journals (Sweden)

    B. Guinot

    2007-01-01

    Full Text Available The aerosol chemical mass closure is revisited and a simple and inexpensive methodology is proposed. This methodology relies on data obtained for aerosol mass, and concentration of the major ions and the two main carbon components, the organic carbon (OC and the black carbon (BC. Atmospheric particles are separated into coarse (AD>2 μm and fine (AD<2 μm fractions and are treated separately. For the coarse fraction the carbonaceous component is minor and assumption is made for the conversion factor k of OC-to-POM (Particulate Organic Matter which is fixed to the value of 1.8 accounting for secondary species. The coarse soluble calcium is shown to display a correlation (regression coefficient f, y axis intercept b with the missing mass. Conversely, the fine fraction is dominated by organic species and assumption is made for dust which is assumed to have the same f factor as the coarse mode dust. The fine mode mass obtained from chemical analyses is then adjusted to the actual weighed mass by tuning the k conversion factor. The k coefficient is kept different in the two modes due to the expected different origins of the organic particles. Using the f and k coefficient obtained from the data set, the mass closure is reached for each individual sample with an undetermined fraction less than 10%. The procedure has been applied to different urban and peri-urban environments in Europe and in Beijing and its efficiency and uncertainties on f and k values are discussed. The f and k coefficients are shown to offer consistent geochemical indications on aerosol origin and transformations. f allows to retrieve dust mass and its value accounting for Ca abundance in dust at the site of investigation may serve as an indicator of dust origin and aerosol interactions with anthropogenic acids. f values were found to vary in the 0.08–0.12 range in European urban areas, and a broader range in Beijing (0.01–0.16. As expected, k appears to be a relevant proxy for

  12. Mass transfer in porous media with heterogeneous chemical reaction

    Directory of Open Access Journals (Sweden)

    Souza S.M.A.G.Ulson de

    2003-01-01

    Full Text Available In this paper, the modeling of the mass transfer process in packed-bed reactors is presented and takes into account dispersion in the main fluid phase, internal diffusion of the reactant in the pores of the catalyst, and surface reaction inside the catalyst. The method of volume averaging is applied to obtain the governing equation for use on a small scale. The local mass equilibrium is assumed for obtaining the one-equation model for use on a large scale. The closure problems are developed subject to the length-scale constraints and the model of a spatially periodic porous medium. The expressions for effective diffusivity, hydrodynamic dispersion, total dispersion and the Darcy's law permeability tensors are presented. Solution of the set of final equations permits the variations of velocity and concentration of the chemical species along the packed-bed reactors to be obtained.

  13. Origin of the chemical noise in ambient mass spectrometry

    International Nuclear Information System (INIS)

    Yang Shuiping; Zhu Zhiqiang; Huang Longzhu; Zhang Xinglei; Zhu Tenggao; Chen Huanwen

    2012-01-01

    The instrumental background of ambient mass spectrometry, (API-MS) is analyzed and the possible potential origins of the background noise is identified. According to the mass spectra obtained using the API-MS instruments by different manufacturers, the characteristic fragment ions all indicated that the background noise are resulted from the phthalates such as diethyl phthalate (DEP), dibutyl phthalate (DBP), benzyl butyl phthalate (BBP), bis (2-ethylhexyl) phthalate (DEHP), and silicones such as decamethylcyclopentasiloxane (D5) and dodecamethylcyclohexasiloxane (D6). These chemicals are probably released from the polymeric materials used in the ionization sources, such as O-type sealing ring etc. In addition, the instrumental background has to be considered especially during the analysis of phthalate and peptide compounds. (authors)

  14. Mass-independent isotope effects in chemical exchange reaction

    International Nuclear Information System (INIS)

    Nishizawa, Kazushige

    2000-01-01

    Isotope effects of some elements in chemical exchange reaction were investigated by use of liquid-liquid extraction, liquid membrane or chromatographic separation. Cyclic polyether was used for every method. All polyethers used in a series of the studies were made clear that they distinguished the isotopes not only by their nuclear masses but also by their nuclear sizes and shapes. Chromium isotopes, for example, were recognized to have enrichment factors being proportional to δ 2 > which is a parameter to show field shift or the nuclear size and shape of the isotope. It follows that the chromium isotopes are separated not by their masses but by their field shift effects. Nuclear spin also played a great role to separate odd mass number isotopes from even mass number isotopes in even atomic number elements. Contribution of the nuclear spin (I=3/2) of 53 Cr to total enrichment factor, ε 53/52 = -0.00028, for 53 Cr to 52 Cr was observed to be, ε spin = -0.0025. (author)

  15. OXALATE MASS BALANCE DURING CHEMICAL CLEANING IN TANK 6F

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, M.; Fink, S.

    2011-07-22

    The Savannah River Remediation (SRR) is preparing Tank 6F for closure. The first step in preparing the tank for closure is mechanical sludge removal. Following mechanical sludge removal, SRS performed chemical cleaning with oxalic acid to remove the sludge heel. Personnel are currently assessing the effectiveness of the chemical cleaning to determine whether the tank is ready for closure. SRR personnel collected liquid samples during chemical cleaning and submitted them to Savannah River National Laboratory (SRNL) for analysis. Following chemical cleaning, they collected a solid sample (also known as 'process sample') and submitted it to SRNL for analysis. The authors analyzed these samples to assess the effectiveness of the chemical cleaning process. Analysis of the anions showed the measured oxalate removed from Tank 6F to be approximately 50% of the amount added in the oxalic acid. To close the oxalate mass balance, the author collected solid samples, leached them with nitric acid, and measured the concentration of cations and anions in the leachate. Some conclusions from this work are: (1) Approximately 65% of the oxalate added as oxalic acid was removed with the decanted liquid. (2) Approximately 1% of the oxalate (added to the tank as oxalic acid) formed precipitates with compounds such as nickel, manganese, sodium, and iron (II), and was dissolved with nitric acid. (3) As much as 30% of the oxalate may have decomposed forming carbon dioxide. The balance does not fully account for all the oxalate added. The offset represents the combined uncertainty in the analyses and sampling.

  16. Structural elucidation of AgAsS2 glass by the analysis of clusters formed during laser desorption ionisation applying quadrupole ion trap time-of-flight mass spectrometry.

    Science.gov (United States)

    Mawale, Ravi Madhukar; Alberti, Milan; Zhang, Bo; Fraenkl, Max; Wagner, Tomas; Havel, Josef

    2016-03-15

    The structure of AgA(s)S2 glass, which has a broad range of applications, is still not well understood and a systematic mass spectrometric analysis of AgA(s)S2 glass is currently not available. Elucidation of the structure should help in the development of this material. The AgA(s)S2 glass was prepared by the melt-quenched technique. Laser desorption ionisation (LDI) using quadrupole ion trap time-of-flight mass spectrometry (QIT-TOFMS) was used to follow the generation of Ag(m)As(n)S(x) clusters. The stoichiometry of the clusters generated was determined via collision-induced dissociation (CID) and modelling of isotopic patterns. The AgA(s)S2 glass was characterised by transmission electron microscopy (TEM), scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) spectroscopy. The LDI of AgA(s)S2 glass leads to the formation of unary (Ag+/− and As(3+)) species, 38 binary (As(n)S(x), Ag(m)S(x)), and 98 ternary (Ag(m)As(n)S(x)) singly charged clusters. The formation of silver-rich nano-grains during AgA(s)S2 glass synthesis has been identified using TEM analysis and also verified by QIT-TOFMS. TOFMS was shown to be a useful technique to study the generation of Ag(m)As(n)S(x )clusters. SEM, TEM and EDX analysis proved that the structure of AgA(s)S2 glass is ‘grain-like’ where grains are either: (1) Silver-rich ‘islands’ (Ag(m,) m up to 39) connected by arsenic and/or sulfur or arsenic sulfide chains or (2) silver sulfide (Ag2S)m (m = 9-20) clusters also similarly inter-connected. This obtained structural information may be useful for the development of ultra-high-density phase-change storage and memory devices using this kind of glass as a base.

  17. Chemical characterization of materials by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Deb, S.B.; Nagar, B.K.; Saxena, M.K.; Ramakumar, K.L.

    2009-11-01

    An Inductively Coupled Plasma Mass Spectrometer was procured for trace elemental determination in diverse samples. Since its installation a number of analytical measurements have been carried out on different sample matrices. These include chemical quality control measurements of nuclear fuel and other materials such as uranium metal. Uranium peroxide, ADU, ThO 2 , UO 2 ; isotopic composition of B, Li; chemical characterization of simulated ThO 2 + 2%UO 2 fuel; sodium zirconium phosphate and trace metallic elements in zirconium; Antarctica rock samples and wet phosphoric acid. Necessary separation methodologies required for effective removal of matrix were indigenously developed. In addition, a rigorous analytical protocol, which includes various calibration methodologies such as mass calibration, response calibration, detector cross calibration and linearity check over the entire dynamic range of 109 required for quantitative determination of elements at trace and ultra trace level,, has been standardized. This report summarizes efforts of RACD that have been put in this direction for the application of ICP-MS for analytical measurements. (author)

  18. Mass loss from Wolf-Rayet stars

    International Nuclear Information System (INIS)

    Willis, A.J.

    1982-01-01

    Recent results relating to the stellar winds and mass loss rates of the WR stars are reviewed, emphasising new data and their interpretation acquired at UV, IR and Radio wavelengths. The subject is discussed under the headings: physical and chemical properties of WR stars (effective temperatures and radiative luminosities; masses; chemical abundances); velocity, ionisation and excitation structure of WR winds; mass loss rates of WR stars; mass loss properties of WR stars in the LMC; comparisons with theoretical models of mass loss; ring nebulae around WR stars; conclusions. (author)

  19. Advisory group on ionising radiation

    International Nuclear Information System (INIS)

    Harrison, J.R.

    1996-01-01

    The Advisory Group on Ionising Radiation has a busy and challenging work programme. Its reports will be published in the Documents of the NRPB series. These may advise further research or could form the basis of formal NRPB advice. Covering the full spectrum of radiation issues at work, in public health and clinical medicine, and the environment, it should enhance the radiation advice available to NRPB. (author)

  20. Electronics in thermal ionisation mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Sattler, E. [Central Bureau for Nuclear Measurements, Geel (Belgium)

    1978-12-15

    The author restricts the discussion to electronic equipment serving for acquisition and handling of analogue measuring data such as: electrometer amplifiers; equipment for digitising the analogue measuring value e.g. voltage-to-frequency converters linked to counter/timer units or digital voltmeters; magnetic field control units.

  1. Effects of intense stratospheric ionisation events

    International Nuclear Information System (INIS)

    Reid, G.C.; McAfee, J.R.; Crutzen, P.J.

    1978-01-01

    High levels of ionising radiation in the Earth's stratosphere will lead to increased concentrations of nitrogen oxides and decreased concentrations of ozone. Changes in the surface environment will include an increased level, of biologically harmful UV radiation, caused by the ozone depletion, and a decreased level of visible solar radiation, due to the presence of major enhancements in the stratospheric concentration of nitrogen dioxide. These changes have been studied quantitatively, using the passage of the Solar System through a supernova remnant shell as an example. Some of the potential environmental changes are a substantial global cooling, abnormally dry conditions, a reduction in global photosynthesis and a large increase in the flux of atmospheric fixed nitrogen to the surface of the Earth. Such events might have been the cause of mass extinctions in the distant past. (Author)

  2. Medical experimentation concerning chemical and biological weapons for mass destruction.

    Science.gov (United States)

    Deutsch, Erwin

    2003-04-01

    This article is the text of a speech originally presented at the Second World Conference on Medical Ethics at Gijon, Spain, on 2 October 2002 under the title "Medical Experimentation Concerning Chemical and Biological Weapons for Mass Destruction: Clinical Design for New Smallpox Vaccines: Ethical and Legal Aspects." Experimentation on vaccines such as smallpox is subject to the usual ethical rules such as the need for informed consent. However, the participants will not often be at risk of catching the disease but expose themselves by taking part in the experimentation. Professor Deutsch explores the implications of this, including the position of vulnerable groups such as children, those with mental handicaps, and those acting under orders such as the miliary, the policy and fire officers.

  3. Cellular automaton model of coupled mass transport and chemical reactions

    International Nuclear Information System (INIS)

    Karapiperis, T.

    1994-01-01

    Mass transport, coupled with chemical reactions, is modelled as a cellular automaton in which solute molecules perform a random walk on a lattice and react according to a local probabilistic rule. Assuming molecular chaos and a smooth density function, we obtain the standard reaction-transport equations in the continuum limit. The model is applied to the reactions a + b ↔c and a + b →c, where we observe interesting macroscopic effects resulting from microscopic fluctuations and spatial correlations between molecules. We also simulate autocatalytic reaction schemes displaying spontaneous formation of spatial concentration patterns. Finally, we propose and discuss the limitations of a simple model for mineral-solute interaction. (author) 5 figs., 20 refs

  4. Mass transport measurements and modeling for chemical vapor infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Starr, T.L.; Chiang, D.Y.; Fiadzo, O.G.; Hablutzel, N. [Georgia Inst. of Tech., Atlanta, GA (United States). School of Materials Science and Engineering

    1997-12-01

    This project involves experimental and modeling investigation of densification behavior and mass transport in fiber preforms and partially densified composites, and application of these results to chemical vapor infiltration (CVI) process modeling. This supports work on-going at ORNL in process development for fabrication of ceramic matrix composite (CMC) tubes. Tube-shaped composite preforms are fabricated at ORNL with Nextel{trademark} 312 fiber (3M Corporation, St. Paul, MN) by placing and compressing several layers of braided sleeve on a tubular mandrel. In terms of fiber architecture these preforms are significantly different than those made previously with Nicalon{trademark} fiber (Nippon Carbon Corp., Tokyo, Japan) square weave cloth. The authors have made microstructure and permeability measurements on several of these preforms and a few partially densified composites so as to better understand their densification behavior during CVI.

  5. Mass Casualty Chemical Incident Operational Framework, Assessment and Best Practices

    Energy Technology Data Exchange (ETDEWEB)

    Greenwalt, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hibbard, W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-08-09

    Emergency response agencies in most US communities are organized, sized, and equipped to manage those emergencies normally expected. Hospitals in particular do not typically have significant excess capacity to handle massive numbers of casualties, as hospital space is an expensive luxury if not needed. Unfortunately this means that in the event of a mass casualty chemical incident the emergency response system will be overwhelmed. This document provides a self-assessment means for emergency managers to examine their response system and identify shortfalls. It also includes lessons from a detailed analysis of five communities: Baltimore, Boise, Houston, Nassau County, and New Orleans. These lessons provide a list of potential critical decisions to allow for pre-planning and a library of best practices that may be helpful in reducing casualties in the event of an incident.

  6. MEMS device for mass market gas and chemical sensors

    Science.gov (United States)

    Kinkade, Brian R.; Daly, James T.; Johnson, Edward A.

    2000-08-01

    Gas and chemical sensors are used in many applications. Industrial health and safety monitors allow companies to meet OSHA requirements by detecting harmful levels of toxic or combustible gases. Vehicle emissions are tested during annual inspections. Blood alcohol breathalizers are used by law enforcement. Refrigerant leak detection ensures that the Earth's ozone layer is not being compromised. Industrial combustion emissions are also monitored to minimize pollution. Heating and ventilation systems watch for high levels of carbon dioxide (CO2) to trigger an increase in fresh air exchange. Carbon monoxide detectors are used in homes to prevent poisoning from poor combustion ventilation. Anesthesia gases are monitored during a patients operation. The current economic reality is that two groups of gas sensor technologies are competing in two distinct existing market segments - affordable (less reliable) chemical reaction sensors for consumer markets and reliable (expensive) infrared (IR) spectroscopic sensors for industrial, laboratory, and medical instrumentation markets. Presently high volume mass-market applications are limited to CO detectros and on-board automotive emissions sensors. Due to reliability problems with electrochemical sensor-based CO detectors there is a hesitancy to apply these sensors in other high volume applications. Applications such as: natural gas leak detection, non-invasive blood glucose monitoring, home indoor air quality, personal/portable air quality monitors, home fire/burnt cooking detector, and home food spoilage detectors need a sensor that is a small, efficient, accurate, sensitive, reliable, and inexpensive. Connecting an array of these next generation gas sensors to wireless networks that are starting to proliferate today creates many other applications. Asthmatics could preview the air quality of their destinations as they venture out into the day. HVAC systems could determine if fresh air intake was actually better than the air

  7. Diseases induced by ionising radiation

    International Nuclear Information System (INIS)

    1984-11-01

    An interim report is presented by the Industrial Injuries Advisory Council in accordance with Section 141 of the Social Security Act 1975 on the question whether the terms of prescription for occupational diseases induced by ionising radiation should be amended to cover a wider range of conditions. A lack of persuasive statistical data has prevented reliable estimates of health risks of radiation workers in the UK to be made. However the report gives details of the progress made so far and the difficulties encountered. (U.K.)

  8. Beam Cooling with ionisation losses

    CERN Document Server

    Rubbia, Carlo; Kadi, Y; Vlachoudis, V

    2006-01-01

    A novel type of particle "cooling", called Ionization Cooling, is applicable to slow (v of the order of 0.1c) ions stored in a small ring. The many traversals through a thin foil enhance the nuclear reaction probability, in a steady configuration in which ionisation losses are recovered at each turn by a RF-cavity. For a uniform target "foil" the longitudinal momentum spread diverges exponentially since faster (slower) particles ionise less (more) than the average. In order to "cool" also longitudinally, a chromaticity has to be introduced with a wedge shaped "foil". Multiple scattering and straggling are then "cooled" in all three dimensions, with a method similar to the one of synchrotron cooling, but valid for low energy ions. Particles then stably circulate in the beam indefinitely, until they undergo for instance nuclear processes in the thin target foil. This new method is under consideration for the nuclear production of a few MeV/A ion beams. Simple reactions, for instance Li 7 + D Li 8 + p, are more ...

  9. Nucleation in an ultra low ionisation environment

    DEFF Research Database (Denmark)

    Enghoff, Martin Andreas Bødker

    in aerosol nucleation. By exposing a controlled volume of air to varying levels of ionising radiation, and with the minimum ionisation level vastly reduced compared to normal surface laboratory conditions, we have provided both a validation of earlier studies of ion-induced nucleation and extended...

  10. Laser ablation synthesis of arsenic-phosphide Asm Pn clusters from As-P mixtures. Laser desorption ionisation with quadrupole ion trap time-of-flight mass spectrometry: The mass spectrometer as a synthesizer.

    Science.gov (United States)

    Kubáček, Pavel; Prokeš, Lubomír; Pamreddy, Annapurna; Peña-Méndez, Eladia María; Conde, José Elias; Alberti, Milan; Havel, Josef

    2018-05-30

    Only a few arsenic phosphides are known. A high potential for the generation of new compounds is offered by Laser Ablation Synthesis (LAS) and when Laser Desorption Ionization (LDI) is coupled with simultaneous Time-Of-Flight Mass Spectrometry (TOFMS), immediate identification of the clusters can be achieved. LAS was used for the generation of arsenic phosphides via laser ablation of phosphorus-arsenic mixtures while quadrupole ion trap time-of-flight mass spectrometry (QIT-TOFMS) was used to acquire the mass spectra. Many new As m P n ± clusters (479 binary and 369 mono-elemental) not yet described in the literature were generated in the gas phase and their stoichiometry determined. The likely structures for some of the observed clusters arbitrary selected (20) were computed by density functional theory (DFT) optimization. LAS is an advantageous approach for the generation of new As m P n clusters, while mass spectrometry was found to be an efficient technique for the determination of cluster stoichiometry. The results achieved might inspire the synthesis of new materials. Copyright © 2018 John Wiley & Sons, Ltd.

  11. Comprehensive Mass Analysis for Chemical Processes, a Case Study on L-Dopa Manufacture

    Science.gov (United States)

    To evaluate the “greenness” of chemical processes in route selection and process development, we propose a comprehensive mass analysis to inform the stakeholders from different fields. This is carried out by characterizing the mass intensity for each contributing chemical or wast...

  12. Complex systems of biological interest stability under ionising radiations

    International Nuclear Information System (INIS)

    Maclot, Sylvain

    2014-01-01

    This PhD work presents the study of stability of molecular systems of biological interest in the gas phase after interaction with ionising radiations. The use of ionising radiation can probe the physical chemistry of complex systems at the molecular scale and thus consider their intrinsic properties. Beyond the fundamental aspect, this work is part of the overall understanding of radiation effects on living organisms and in particular the use of ionizing radiation in radiotherapy. Specifically, this study focused on the use of low-energy multiply charged ions (tens of keV) provided by the GANIL (Caen), which includes most of the experiments presented. In addition, experiments using VUV photons were also conducted at synchrotron ELETTRA (Trieste, Italy). The bio-molecular systems studied are amino acids and nucleic acid constituents. Using an experimental crossed beams device allows interaction between biomolecules and ionising radiation leads mainly to the ionization and fragmentation of the system. The study of its relaxation dynamics is by time-of-flight mass spectrometry coupled to a coincidences measurements method. It is shown that an approach combining experiment and theory allows a detailed study of the fragmentation dynamics of complex systems. The results indicate that fragmentation is generally governed by the Coulomb repulsion but the intramolecular rearrangements involve specific relaxation mechanisms. (author) [fr

  13. Health Service use of ionising radiations: Guidance

    International Nuclear Information System (INIS)

    1995-01-01

    This booklet gives outline guidance on the use of ionising radiations in the Health Service in the United Kingdom. Extensive reference is made to documents where more detailed information may be found. The guidance covers general advice on the medical use of ionising radiations, statutory requirements, and guidance on selected Health Service issues such as patient identification procedures, information management systems, deviations from prescribed radiation dose, imaging and radiotherapy. (57 references) (U.K.)

  14. Ionising radiation - physical and biological effects

    International Nuclear Information System (INIS)

    Holter, Oe.; Ingebretsen, F.; Parr, H.

    1979-01-01

    The physics of ionising radiation is briefly presented. The effects of ionising radiation on biological cells, cell repair and radiosensitivity are briefly treated, where after the effects on man and mammals are discussed and related to radiation doses. Dose limits are briefly discussed. The genetic effects are discussed separately. Radioecology is also briefly treated and a table of radionuclides deriving from reactors, and their radiation is given. (JIW)

  15. Introduction to computational mass transfer with applications to chemical engineering

    CERN Document Server

    Yu, Kuo-Tsung

    2017-01-01

    This book offers an easy-to-understand introduction to the computational mass transfer (CMT) method. On the basis of the contents of the first edition, this new edition is characterized by the following additional materials. It describes the successful application of this method to the simulation of the mass transfer process in a fluidized bed, as well as recent investigations and computing methods for predictions for the multi-component mass transfer process. It also demonstrates the general issues concerning computational methods for simulating the mass transfer of the rising bubble process. This new edition has been reorganized by moving the preparatory materials for Computational Fluid Dynamics (CFD) and Computational Heat Transfer into appendices, additions of new chapters, and including three new appendices on, respectively, generalized representation of the two-equation model for the CMT, derivation of the equilibrium distribution function in the lattice-Boltzmann method, and derivation of the Navier-S...

  16. A Discussion about Ionising and Non-Ionising Radiation and the Critical Issue of Mobile Phones

    Science.gov (United States)

    Kontomaris, Stylianos-Vasileios; Malamou, Anna

    2018-01-01

    Electromagnetic radiation is one of the most important issues affecting peoples' lives today. The misunderstanding of students and the general population of the effects of electromagnetic radiation is a problem which must be eliminated. Thus, a discussion about ionising and non-ionising radiation focusing on the crucial issue of radiation emitted…

  17. Mass spectrometric confirmation criterion for product-ion spectra generated in flow-injection analysis. Environmental application

    NARCIS (Netherlands)

    Geerdink, R.B.; Niessen, W.M.A.; Brinkman, U.A.T.

    2001-01-01

    The suitability of a confirmation criterion recently recommended in the Netherlands for gas chromatography with mass spectrometric detection (GC-MS), was evaluated for flow-injection analysis (FIA) with atmospheric pressure chemical ionisation MS-MS detection. The main feature of the criterion is

  18. New Polymer Coatings for Chemically Selective Mass Sensors

    Science.gov (United States)

    Sims, S. C.; Wright, Cassandra; Cobb, J.; McCalla, T.; Revelle, R.; Morris, V. R.; Pollack, S. K.

    1997-01-01

    There is a current need to develop sensitive and chemically specific sensors for the detection of nitric acid for in-situ measurements in the atmosphere. Polymer coatings have been synthesized and tested for their sensitivity and selectivity to nitric acid. A primary requirement for these polymers is detectability down to the parts per trillion range. The results of studies using these polymers as coatings for quartz crystal microbalances (QCM) and surface acoustic wave (SAW) devices will be presented.

  19. Ionised Jets Associated With Massive Young Stellar Objects

    Science.gov (United States)

    Purser, Simon John Derek

    2017-09-01

    This thesis focuses on the phenomena of ionised jets associated with massive young stellar objects. Firstly a study was conducted with the aim to establish a statistical sample of such objects. Radio observations towards a sample of 49 MYSOs resulted in the detection of 28 objects classified as ionised jets. The jets’ radio luminosities scaled with their MYSOs’ bolometric luminosities in the same way as for low-mass examples. This infers that the jet launching and collimation mechanisms of high-mass jets are very similar to that in their low-mass counterparts and they are ejected for the last ≤65000 yr of the MYSO phase. Interestingly non-thermal emission was regularly detected towards spatially distinct radio lobes (associated with ˜50% of the jets), suggesting the presence of synchrotron emission and therefore, magnetic fields. With an average spectral index of ¯α=‑0. 55 (indicative of the 1st order Fermi acceleration mechanism) it is concluded these lobes are the result of shocks in the jets’ stream. My second science chapter is a study of radio variability, precession and proper motions towards a subset of objects from the first chapter. Over a two year time period, no significant variability and only one example of proper motion (1800±600 km s‑1) was detected. Precession was found to be commonplace however and if it arises as the result of binary interactions, we infer orbital radii between 30 and 1800 au for the binary companions. Lastly, high-resolution, VLA observations at C and Q-bands were analysed to extend the known sample of MYSOs harbouring ionised jets into the northern hemisphere. Only 3 radio sources were detected possessing jet-like characteristics towards the work’s sub-sample of 8 IRDCs containing 44 mm-cores (in our field of view), highlighting the radio-quiet (≳30μJy) nature of this early phase in massive star formation. Towards the RMS survey derived sample of 48 MYSOs, a total of 38 radio sources with jet

  20. Characterization of typical chemical background interferences in atmospheric pressure ionization liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Guo, Xinghua; Bruins, Andries P.; Covey, Thomas R.

    2006-01-01

    The structures and origins of typical chemical background noise ions in positive atmospheric pressure ionization liquid chromatography/mass spectrometry (API LC/MS) are investigated and summarized in this study. This was done by classifying chemical background ions using precursor and product ion

  1. Cellular automaton model of mass transport with chemical reactions

    International Nuclear Information System (INIS)

    Karapiperis, T.; Blankleider, B.

    1993-10-01

    The transport and chemical reactions of solutes are modelled as a cellular automaton in which molecules of different species perform a random walk on a regular lattice and react according to a local probabilistic rule. The model describes advection and diffusion in a simple way, and as no restriction is placed on the number of particles at a lattice site, it is also able to describe a wide variety of chemical reactions. Assuming molecular chaos and a smooth density function, we obtain the standard reaction-transport equations in the continuum limit. Simulations on one-and two-dimensional lattices show that the discrete model can be used to approximate the solutions of the continuum equations. We discuss discrepancies which arise from correlations between molecules and how these discrepancies disappear as the continuum limit is approached. Of particular interest are simulations displaying long-time behaviour which depends on long-wavelength statistical fluctuations not accounted for by the standard equations. The model is applied to the reactions a + b ↔ c and a + b → c with homogeneous and inhomogeneous initial conditions as well as to systems subject to autocatalytic reactions and displaying spontaneous formation of spatial concentration patterns. (author) 9 figs., 34 refs

  2. Impact assessment of ionising radiation in wildlife

    International Nuclear Information System (INIS)

    2001-01-01

    This R and D project was commissioned by the Environment Agency and English Nature in January 2001 to provide up-to-date information on ionising radiation impact to wildlife, upon which a robust assessment approach may be developed. The methodology will provide an interim approach, whilst awaiting the outcome of the European Commission funded project 'Framework for Assessment of Environmental Impact' (FASSET) due to end in October 2003. The aims of the report were: to summarise the latest research on the behaviour, transfer and impact of ionising radiation effects on wildlife; to outline and review relevant European Directives which have impacted on the requirements to assess the impact to wildlife from ionising radiation in the UK; to consider the role of regulatory bodies in assessing the impact of ionising radiation on wildlife with respect to England and Wales; to make recommendations on the relative biological effectiveness of different types of radiation with respect to wildlife; and to recommend an approach with which to assess the 'scale of risk' to wildlife from the effects of ionising radiation, with spreadsheets to support the methodology. The report describes the behaviour and transfer of radionuclides in a number of different ecosystem types. Particular emphasis is placed on those ecosystems most likely to be impacted by the authorised discharges of radioactivity within the UK. As there is no international consensus on the approach to be taken to assess the impact of ionising radiation on wildlife, some countries have adopted their own legislation. The report evaluates these regulatory frameworks and describe the current UK position

  3. Ionised media and fractures: application to cartilaginous tissues and oil industry

    NARCIS (Netherlands)

    Huyghe, J.M.R.J.; Kraaijeveld, F.; Remmers, J.J.C.; Borst, de R.; Denier, J; Finn, M.D.; Mattner, T

    2008-01-01

    ionized media are ubiquitous in nature. Our body holds onto water through ionised macromolecules that bind water up to a 1000 times their own mass. Clays and shales do a similar trick in the geoworld. Localization of deformation and fractures are very common. Bore hole instability through fracture

  4. Impact assessment of ionising radiation on wildlife

    International Nuclear Information System (INIS)

    Copplestone, D.; Bielby, S.; Jones, S.

    2001-01-01

    This R and D project was commissioned by the Environment Agency and English Nature in January 2001 to provide up-to-date information on the impacts of ionising radiation on wildlife, upon which a robust assessment approach may be developed. This approach will also feed into the European Commission funded project 'Framework for Assessment of Environmental Impact' (FASSET), due to complete in October 2003. This report describes the behaviour and transport of radionuclides in the environment, considers the impact of ionising radiation on wildlife, and makes recommendations on an approach for the impact assessment of ionising radiation on wildlife for England and Wales. The assessment approach focuses on three ecosystems representative of those considered potentially most at risk from the impact of authorised radioactive discharges, namely a coastal grassland (terrestrial ecosystem); estuarine and freshwater ecosystems. The likely scale of the impact on wildlife is also assessed in light of a preliminary analysis based on this assessment approach. The aims of the report are: to summarise the latest research on the behaviour, transfer and impact of ionising radiation effects on wildlife; an outline and review of the relevant European and national legislation which has impacts on the requirements for assessments of the impact of ionising radiation on wildlife in the UK; to consider the role of regulatory bodies in assessing the impact of ionising radiation on wildlife with respect to England and Wales; to make recommendations on the relative biological effectiveness of different types of radiation with respect to wildlife; and to recommend an approach to assess the impacts to wildlife from ionising radiation from authorised discharges in England and Wales, with spreadsheets to support the methodology. The report demonstrates the behaviour and transfer of radionuclides in a number of different ecosystem types. Particular emphasis is placed on exposure pathways in those

  5. The ionisation parameter of star-forming galaxies evolves with the specific star formation rate

    Science.gov (United States)

    Kaasinen, Melanie; Kewley, Lisa; Bian, Fuyan; Groves, Brent; Kashino, Daichi; Silverman, John; Kartaltepe, Jeyhan

    2018-04-01

    We investigate the evolution of the ionisation parameter of star-forming galaxies using a high-redshift (z ˜ 1.5) sample from the FMOS-COSMOS survey and matched low-redshift samples from the Sloan Digital Sky Survey. By constructing samples of low-redshift galaxies for which the stellar mass (M*), star formation rate (SFR) and specific star formation rate (sSFR) are matched to the high-redshift sample we remove the effects of an evolution in these properties. We also account for the effect of metallicity by jointly constraining the metallicity and ionisation parameter of each sample. We find an evolution in the ionisation parameter for main-sequence, star-forming galaxies and show that this evolution is driven by the evolution of sSFR. By analysing the matched samples as well as a larger sample of z physically consistent with the definition of the ionisation parameter, a measure of the hydrogen ionising photon flux relative to the number density of hydrogen atoms.

  6. Constraints on continental crustal mass loss via chemical weathering using lithium and its isotopes

    Science.gov (United States)

    Rudnick, R. L.; Liu, X. M.

    2012-04-01

    The continental crust has an "intermediate" bulk composition that is distinct from primary melts of peridotitic mantle (basalt or picrite). This mismatch between the "building blocks" and the "edifice" that is the continental crust points to the operation of processes that preferentially remove mafic to ultramafic material from the continents. Such processes include lower crustal recycling (via density foundering or lower crustal subduction - e.g., relamination, Hacker et al., 2011, EPSL), generation of evolved melts via slab melting, and/or chemical weathering. Stable isotope systems point to the influence of chemical weathering on the bulk crust composition: the oxygen isotope composition of the bulk crust is distinctly heavier than that of primary, mantle-derived melts (Simon and Lecuyer, 2005, G-cubed) and the Li isotopic composition of the bulk crust is distinctly lighter than that of mantle-derive melts (Teng et al., 2004, GCA; 2008, Chem. Geol.). Both signatures mark the imprint of chemical weathering on the bulk crust composition. Here, we use a simple mass balance model for lithium inputs and outputs from the continental crust to quantify the mass lost due to chemical weathering. We find that a minimum of 15%, a maximum of 60%, and a best estimate of ~40% of the original juvenile rock mass may have been lost via chemical weathering. The accumulated percentage of mass loss due to chemical weathering leads to an average global chemical weathering rate (CWR) of ~ 1×10^10 to 2×10^10 t/yr since 3.5 Ga, which is about an order of magnitude higher than the minimum estimates based on modern rivers (Gaillardet et al., 1999, Chem. Geol.). While we cannot constrain the exact portion of crustal mass loss via chemical weathering, given the uncertainties of the calculation, we can demonstrate that the weathering flux is non-zero. Therefore, chemical weathering must play a role in the evolution of the composition and mass of the continental crust.

  7. EDDIX--a database of ionisation double differential cross sections.

    Science.gov (United States)

    MacGibbon, J H; Emerson, S; Liamsuwan, T; Nikjoo, H

    2011-02-01

    The use of Monte Carlo track structure is a choice method in biophysical modelling and calculations. To precisely model 3D and 4D tracks, the cross section for the ionisation by an incoming ion, double differential in the outgoing electron energy and angle, is required. However, the double differential cross section cannot be theoretically modelled over the full range of parameters. To address this issue, a database of all available experimental data has been constructed. Currently, the database of Experimental Double Differential Ionisation Cross sections (EDDIX) contains over 1200 digitalised experimentally measured datasets from the 1960s to present date, covering all available ion species (hydrogen to uranium) and all available target species. Double differential cross sections are also presented with the aid of an eight parameter functions fitted to the cross sections. The parameters include projectile species and charge, target nuclear charge and atomic mass, projectile atomic mass and energy, electron energy and deflection angle. It is planned to freely distribute EDDIX and make it available to the radiation research community for use in the analytical and numerical modelling of track structure.

  8. Effects of main-sequence mass loss on stellar and galactic chemical evolution

    International Nuclear Information System (INIS)

    Guzik, J.A.

    1988-01-01

    L.A. Willson, G.H. Bowen and C. Struck-Marcell have proposed that 1 to 3 solar mass stars may experience evolutionarily significant mass loss during the early part of their main-sequence phase. The suggested mass-loss mechanism is pulsation, facilitated by rapid rotation. Initial mass-loss rates may be as large as several times 10 -9 M mass of sun/yr, diminishing over several times 10 8 years. The author attempts to test this hypothesis by comparing some theoretical implications with observations. Three areas are addressed: Solar models, cluster HR diagrams, and galactic chemical evolution. Mass-losing solar models were evolved that match the Sun's luminosity and radius at its present age. The most extreme viable models have initial mass 2.0 M 0 , and mass-loss rates decreasing exponentially over 2-3 x 10 8 years. Evolution calculations incorporating main-sequence mass loss were completed for a grid of models with initial masses 1.25 to 2.0 M mass of sun and mass loss timescales 0.2 to 2.0 Gry. Cluster HR diagrams synthesized with these models confirm the potential for the hypothesis to explain observed spreads or bifurcations in the upper main sequence, blue stragglers, anomalous giants, and poor fits of main-sequence turnoffs by standard isochrones. Simple closed galactic chemical evolution models were used to test the effects of main-sequence mass loss on the F and G dwarf distribution. Stars between 3.0 M mass of sun and a metallicity-dependent lower mass are assumed to lose mass. The models produce a 30 to 60% increase in the stars to stars-plus-remnants ratio, with fewer early-F dwarfs and many more late-F dwarfs remaining on the main sequence to the present

  9. Doubling potential of fibroblasts from different species after ionising radiation

    International Nuclear Information System (INIS)

    Macieira-Coelho, A.; Diatloff, C.; Malaise, E.

    1976-01-01

    It is stated that whereas chicken fibroblasts invariably die after a certain number of doublings in vitro, and this fact is never altered by chemical or physical agents, mouse fibroblasts invariably acquire spontaneously an infinite growth potential. In the human species fibroblasts never acquire spontaneously the capacity to divide for ever, although they can become permanent cell lines after treatment with certain viruses. This behaviour of fibroblasts in vitro has been attributed to different nutritional requirements. Experiments are described with human and mouse fibroblasts in which it was found that the response to ionising radiation matches the relative tendencies of the fibroblasts to yield permanent cell lines. Irradiation was commenced during the phase of active proliferation. Human fibroblast cultures irradiated with 100 R stopped dividing earlier than the controls, whereas cultures irradiated with 200, 300 and 500 R had the same lifespan as the control cultures. Cultures irradiated with 400 R showed the longest survival. With mouse fibroblasts the growth curves of the irradiated cells were of the same type as in the controls, but recovery occurred earlier. The results indicated that ionising radiation accelerates a natural phenomenon; in cells with a limited growth potential (chicken) it shortens the lifespan, whereas in cells that can acquire an unlimited growth potential (mouse) it accelerates acquisition of this potential; human fibroblasts showed an intermediate response, since ionising radiation neither established the cultures as with mouse cells nor reduced the number of cells produced as with chicken fibroblasts. Possible explanations for the different behaviour of the species are offered. (U.K.)

  10. Profiling the metabolic signals involved in chemical communication between microbes using imaging mass spectrometry.

    Science.gov (United States)

    Stasulli, Nikolas M; Shank, Elizabeth A

    2016-11-01

    The ability of microbes to secrete bioactive chemical signals into their environment has been known for over a century. However, it is only in the last decade that imaging mass spectrometry has provided us with the ability to directly visualize the spatial distributions of these microbial metabolites. This technology involves collecting mass spectra from multiple discrete locations across a biological sample, yielding chemical ‘maps’ that simultaneously reveal the distributions of hundreds of metabolites in two dimensions. Advances in microbial imaging mass spectrometry summarized here have included the identification of novel strain- or coculture-specific compounds, the visualization of biotransformation events (where one metabolite is converted into another by a neighboring microbe), and the implementation of a method to reconstruct the 3D subsurface distributions of metabolites, among others. Here we review the recent literature and discuss how imaging mass spectrometry has spurred novel insights regarding the chemical consequences of microbial interactions.

  11. The chemical composition and mineralogy of meteorites measured with very high spatial resolution by a laser mass spectrometer for in situ planetary research

    Science.gov (United States)

    Brigitte Neuland, Maike; Mezger, Klaus; Tulej, Marek; Frey, Samira; Riedo, Andreas; Wurz, Peter; Wiesendanger, Reto

    2017-04-01

    asteroid. [1] Wurz, P., Whitby, J., Managadze, G. , "Laser Mass Spectrometry in Planetary Science", AIP Conf.Proc. CP1144(2009): 70-75. [2] Rohner, U., Whitby, J.A. and Wurz, P. "A miniature laser ablation time-of-flight mass spectrometer for in situ planetary exploration", Measurement Science and Technology 14 (2003): 2159-2164. [3] Riedo, A., Bieler, A., Neuland, M., Tulej, M. and Wurz, P., "Performance evaluation of a miniature laser ablation time-of-flight mass spectrometer designed for in situ investigations in planetary space research", Journal of Mass Spectrometry 48 (2013): 1 -15 [4] Neuland, M.B., Grimaudo, V., Mezger, K., Moreno-García, P., Riedo, A., Tulej, M. and Wurz, P., "Quantitative measurement of the chemical composition of geological standards with a miniature laser ablation/ionisation mass spectrometer designed for in situ application in space research", Meas. Sci. Technol. 27(2016), article ID:035904, 1 - 13. [5] Tulej, M., Neubeck, A., Ivarsson, M., Riedo, A., Neuland, M.B., Meyer, S. and Wurz, P., "Chemical composition of micrometer-sized filaments in an aragonite host by a miniature laser ablation/ionization mass spectrometer", Astrobiol., 15 (2015): 669 - 682.

  12. The work of the ILO in the field of protection of workers against ionising and non-ionising radiations

    International Nuclear Information System (INIS)

    Coppee, G.H.

    1980-01-01

    A chronological account since 1934 of the activities of the International Labour Organization (ILO) in the protection of workers against risks due to ionising and non-ionising radiations is given. Several ILO publication on safety standards and codes of practice for protection against mainly ionising radiation in various occupational situations are indicated. A more intensive study by the ILO on the protection of workers against non-ionising radiation was proposed for 1980-81. (UK)

  13. The ENEA calibration service for ionising radiations

    International Nuclear Information System (INIS)

    Monteventi, F.; Sermenghi, I.

    1999-01-01

    The report describes all the facilities available at the the service of the ENEA Calibration Service for Ionising Radiations at Bologna (Italy). It gives a detailed description of all equipments qualified for photon fields metrology including the secondary standards and the calibration procedures performed for radiation monitoring devices and dosemeters [it

  14. Mass and chemically speciated size distribution of Prague aerosol using an aerosol dryer - The influence of air mass origin

    Czech Academy of Sciences Publication Activity Database

    Schwarz, Jaroslav; Štefancová, Lucia; Maenhaut, W.; Smolík, Jiří; Ždímal, Vladimír

    2012-01-01

    Roč. 437, OCT 15 (2012), s. 348-362 ISSN 0048-9697 R&D Projects: GA ČR GA205/09/2055; GA ČR GAP209/11/1342; GA MŠk ME 941 Grant - others:SRF GU(BE) 01S01306 Institutional support: RVO:67985858 Keywords : atmospheric aerosols * mass size distribution * chemical composition Subject RIV: DI - Air Pollution ; Quality Impact factor: 3.258, year: 2012

  15. Dedicated Trigger for Highly Ionising Particles at ATLAS

    CERN Document Server

    Katre, Akshay; The ATLAS collaboration

    2015-01-01

    In 2012, a novel strategy was designed to detect signatures of Highly Ionising Particles (HIPs) such as magnetic monopoles, dyons or Q-balls with ATLAS. A dedicated trigger was developed and deployed for proton-proton collisions at a centre of mass energy of 8 TeV. It uses the Transition Radiation Tracker (TRT) system, applying an algorithm distinct from standard tracking ones. The high threshold (HT) readout capability of the TRT is used to distinguish HIPs from other background processes. The trigger requires significantly lower energy depositions in the electromagnetic calorimeters and is thereby capable of probing a larger range of HIP masses and charges. A description of the algorithm for this newly developed trigger is presented, along with a comparitive study of its performance during the 2012 data-taking period with respect to previous efforts.

  16. Electron impact ionisation cross sections of iron oxides

    Science.gov (United States)

    Huber, Stefan E.; Mauracher, Andreas; Sukuba, Ivan; Urban, Jan; Maihom, Thana; Probst, Michael

    2017-12-01

    We report electron impact ionisation cross sections (EICSs) of iron oxide molecules, FexOx and FexOx+1 with x = 1, 2, 3, from the ionisation threshold to 10 keV, obtained with the Deutsch-Märk (DM) and binary-encounter-Bethe (BEB) methods. The maxima of the EICSs range from 3.10 to 9 . 96 × 10-16 cm2 located at 59-72 eV and 5.06 to 14.32 × 10-16 cm2 located at 85-108 eV for the DM and BEB approaches, respectively. The orbital and kinetic energies required for the BEB method are obtained by employing effective core potentials for the inner core electrons in the quantum chemical calculations. The BEB cross sections are 1.4-1.7 times larger than the DM cross sections which can be related to the decreasing population of the Fe 4s orbitals upon addition of oxygen atoms, together with the different methodological foundations of the two methods. Both the DM and BEB cross sections can be fitted excellently to a simple analytical expression used in modelling and simulation codes employed in the framework of nuclear fusion research. Supplementary material in the form of one pdf file available from the Journal web page at http://https://doi.org/10.1140/epjd/e2017-80308-2.

  17. Electron impact ionisation cross-sections of 2-heptanone

    Science.gov (United States)

    Vacher, J. R.; Blin-Simiand, N.; Jorand, F.; Pasquiers, S.

    2005-01-01

    The electron impact ionisation of 2-heptanone between 13 and 78 eV is studied using mass spectrometry. CH3C(O)CH2CH2CH2CH2CH3+ and fragment ions are produced with a total cross-section of 5 × 10-16 cm2 towards 50 eV. Two ions, identified as CH3CO+ (43 amu) and CH3C(OH)CH2+ (58 amu), contribute to about 60% of the total cross-section for electron energies above the ionisation threshold. The detected ions are identified using ab initio calculations. For E = 14 eV, the ion of 58 amu is the most abundant followed by an ion of 59 amu identified as being CH3C(OH)CH3+; they result from a bond cleavage with one or two H atom rearrangements. For E >= 48 eV, the ion of 43 amu is the most abundant; it results from an [alpha]-cleavage reaction in the molecular ion.

  18. Introducing Biological Microdosimetry for Ionising Radiation

    International Nuclear Information System (INIS)

    Scott, B.R.; Schoellnberger, H.

    2000-01-01

    Microdosimetry is important for radiation protection, for understanding mechanisms of radiation action, and for radiation risk assessment. This article introduces a generic, Monte Carlo based approach to biological microdosimetry for ionising radiation. Our Monte Carlo analyses are carried out with a widely used Crystal Ball software. The approach to biological microdosimetry presented relates to quantal biological effects data (e.g. cell survival, mutagenesis, neoplastic transformation) for which there is an initial linear segment to the dose-response curve. The macroscopic dose data considered were selected such that is could be presumed that the vast majority of cells at risk have radiation dose delivered to their critical target. For cell killing, neoplastic transformation, and mutagenesis, the critical biological target for radiation is presumed to be DNA. Our approach to biological microdosimetry does not require detailed information about the mass, volume, and shape of the critical biological target. Further, one does not have to know what formal distribution function applies to the microdose distribution. However, formal distributions are required for the biological data used to derive the non-parametric microdose distributions. Here, we use the binomial distribution to characterise the variability in the number of cells affected by a fixed macroscopic dose. Assuming this variability to arise from variability in the microscopic dose to the critical biological target, a non-parametric microdose distribution is generated by the standard Monte Carlo method. The non-parametric distribution is then fitted using a set of formal distributions (beta, exponential, extreme value, gamma, logistic, log-normal, normal, Pareto, triangular, uniform, and Weibull). The best fit is then evaluated based on statistical criteria (chi-square test). To demonstrate the application of biological microdosimetry, the standard Monte Carlo method is used with radiobiological data for

  19. Introducing Biological Microdosimetry for Ionising Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Scott, B.R.; Schoellnberger, H

    2000-07-01

    Microdosimetry is important for radiation protection, for understanding mechanisms of radiation action, and for radiation risk assessment. This article introduces a generic, Monte Carlo based approach to biological microdosimetry for ionising radiation. Our Monte Carlo analyses are carried out with a widely used Crystal Ball software. The approach to biological microdosimetry presented relates to quantal biological effects data (e.g. cell survival, mutagenesis, neoplastic transformation) for which there is an initial linear segment to the dose-response curve. The macroscopic dose data considered were selected such that is could be presumed that the vast majority of cells at risk have radiation dose delivered to their critical target. For cell killing, neoplastic transformation, and mutagenesis, the critical biological target for radiation is presumed to be DNA. Our approach to biological microdosimetry does not require detailed information about the mass, volume, and shape of the critical biological target. Further, one does not have to know what formal distribution function applies to the microdose distribution. However, formal distributions are required for the biological data used to derive the non-parametric microdose distributions. Here, we use the binomial distribution to characterise the variability in the number of cells affected by a fixed macroscopic dose. Assuming this variability to arise from variability in the microscopic dose to the critical biological target, a non-parametric microdose distribution is generated by the standard Monte Carlo method. The non-parametric distribution is then fitted using a set of formal distributions (beta, exponential, extreme value, gamma, logistic, log-normal, normal, Pareto, triangular, uniform, and Weibull). The best fit is then evaluated based on statistical criteria (chi-square test). To demonstrate the application of biological microdosimetry, the standard Monte Carlo method is used with radiobiological data for

  20. The thermodynamics of heat- and mass exchange in chemical engineering. Vol. 1. 2. rev. ed.

    International Nuclear Information System (INIS)

    Matz, G.

    1979-01-01

    The second and completely revised edition of the approved textbook 'The thermodynamics of heat- and mass exchange in chemical engineering' is devoted to students of technical and natural science disciplines as well as to practicians and scientists, which are confronted with thermodynamical problems of chemical engineering. Starting from the different phases and properties of matter, the first and the second law of thermodynamics are discussed together with many applications. After an introduction of the equilibrium state, the general principle of similarity for heat- and mass exchange is discussed, considering in particular the heat- and mass exchange in the counter flow between two phases. In a final chapter, the heat- and mass exchange between the vapor- and liquid phase is discussed, with special emphasis on problems as evaporation and drying. (orig./HK) [de

  1. Characterization of Nitrated Sugar Alcohols by Atmospheric-Pressure Chemical-Ionization Mass Spectrometry

    Science.gov (United States)

    2016-07-27

    Chemical, Microsystem, and Nanoscale Technology Group MIT-Lincoln Laboratory, Lexington, MA 02420 jude.kelley@ll.mit.edu RATIONALE: The...formed by the loss of NO2, HNO2, NO3, and CH2NO2 groups , and in the presence of dichloromethane chlorinated adduct ions were observed. It was determined...explosives trace detection, such as electrospray ionization ( ESI ) and atmospheric pressure chemical ionization (APCI) mass spectrometry (MS) along

  2. Mass spectrometric study of selected precursors and degradation products of chemical warfare agents

    Czech Academy of Sciences Publication Activity Database

    Papoušková, B.; Bednář, P.; Fryšová, I.; Stýskala, J.; Hlaváč, J.; Barták, P.; Ulrichová, J.; Jirkovský, Jaromír; Lemr, K.

    2007-01-01

    Roč. 42, č. 12 (2007), s. 1550-1561 ISSN 1076-5174 Grant - others:The Organization for the Prohibition of Chemical Weapons (NL) L/ICA/ICB/84322/04 Institutional research plan: CEZ:AV0Z40400503 Source of funding: V - iné verejné zdroje Keywords : mass spectrometry * chemical warfare agent * high performance liquid chromatography * LC/MS Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 3.062, year: 2007

  3. Mass spectrometry in identification of ecotoxicants including chemical and biological warfare agents

    International Nuclear Information System (INIS)

    Lebedev, Albert T.

    2005-01-01

    Mass spectrometry is a unique tool to detect and identify trace levels of organic and bioorganic compounds as well as microorganisms in the environment. The range of potential chemical warfare (CW) and biological warfare (BW) agents is very broad. An important advantage of mass spectrometry over other techniques involves potential for full spectrum detection of chemical and biological agents including mid-spectrum materials (i.e. bioactive peptides, toxins, etc.) for which biological approaches are inadequate. Being very fast (seconds and minutes), extremely sensitive (zeptomoles 10 -21 ), and informative (detailed qualitative and quantitative composition of mixtures containing hundreds of chemicals), mass spectrometry is a principal analytical tool at the sites of destruction of CW. Due to its unique features, mass spectrometry is applied not only for the detection of CW agents, but for the analysis of products of metabolism and degradation of these agents in organisms or environment as well. The present paper deals with some examples of successful application of mass spectrometry for the analyses of ecotoxicants, chemical warfare agents, explosives, and microorganisms including biology warfare agents

  4. Coupled sulfur isotopic and chemical mass transfer modeling: Approach and application to dynamic hydrothermal processes

    International Nuclear Information System (INIS)

    Janecky, D.R.

    1988-01-01

    A computational modeling code (EQPSreverse arrowS) has been developed to examine sulfur isotopic distribution pathways coupled with calculations of chemical mass transfer pathways. A post processor approach to EQ6 calculations was chosen so that a variety of isotopic pathways could be examined for each reaction pathway. Two types of major bounding conditions were implemented: (1) equilibrium isotopic exchange between sulfate and sulfide species or exchange only accompanying chemical reduction and oxidation events, and (2) existence or lack of isotopic exchange between solution species and precipitated minerals, parallel to the open and closed chemical system formulations of chemical mass transfer modeling codes. All of the chemical data necessary to explicitly calculate isotopic distribution pathways is generated by most mass transfer modeling codes and can be input to the EQPS code. Routines are built in to directly handle EQ6 tabular files. Chemical reaction models of seafloor hydrothermal vent processes and accompanying sulfur isotopic distribution pathways illustrate the capabilities of coupling EQPSreverse arrowS with EQ6 calculations, including the extent of differences that can exist due to the isotopic bounding condition assumptions described above. 11 refs., 2 figs

  5. Effects of chemical reaction on moving isothermal vertical plate with variable mass diffusion

    Directory of Open Access Journals (Sweden)

    Muthucumaraswamy R.

    2003-01-01

    Full Text Available An exact solution to the problem of flow past an impulsively started infinite vertical isothermal plate with variable mass diffusion is presented here, taking into account of the homogeneous chemical reaction of first-order. The dimensionless governing equations are solved by using the Laplace - transform technique. The velocity and skin-friction are studied for different parameters like chemical reaction parameter, Schmidt number and buoyancy ratio parameter. It is observed that the veloc­ity increases with decreasing chemical reaction parameter and increases with increasing buoyancy ratio parameter.

  6. Rapid screening of anabolic steroids in horse urine with ultra-high-performance liquid chromatography/tandem mass spectrometry after chemical derivatisation.

    Science.gov (United States)

    Wong, Colton H F; Leung, David K K; Tang, Francis P W; Wong, Jenny K Y; Yu, Nola H; Wan, Terence S M

    2012-04-06

    Liquid chromatography/mass spectrometry (LC/MS) has been successfully applied to the detection of anabolic steroids in biological samples. However, the sensitive detection of saturated hydroxysteroids, such as androstanediols, by electrospray ionisation (ESI) is difficult because of their poor ability to ionise. In view of this, chemical derivatisation has been used to enhance the detection sensitivity of hydroxysteroids by LC/MS. This paper describes the development of a sensitive ultra-high-performance liquid chromatography/tandem mass spectrometry (UHPLC/MS/MS) method for the screening of anabolic steroids in horse urine by incorporating a chemical derivatisation step, using picolinic acid as the derivatisation reagent. The method involved solid-phase extraction (SPE) of both free and conjugated anabolic steroids in horse urine using a polymer-based SPE cartridge (Abs Elut Nexus). The conjugated steroids in the eluate were hydrolysed by methanolysis and the resulting extract was further cleaned up by liquid-liquid extraction. The resulting free steroids in the extract were derivatised with picolinic acid to form the corresponding picolinoyl esters and analysed by UHPLC/MS/MS in the positive ESI mode with selected-reaction-monitoring. Separation of the targeted steroids was performed on a C18 UHPLC column. The instrument turnaround time was 10.5 min inclusive of post-run equilibration. A total of thirty-three anabolic steroids (including 17β-estradiol, 5(10)-estrene-3β,17α-diol, 5α-estrane-3β,17α-diol, 17α-ethyl-5α-estran-3α,17β-diol, 17α-methyl-5α-androstan-3,17β-diols, androstanediols, nandrolone and testosterone) spiked in negative horse urine at the QC levels (ranging from 0.75 to 30 ng/mL) could be consistently detected. The intra-day and inter-day precisions (% RSD) for the peak area ratios were around 7-51% and around 1-72%, respectively. The intra-day and inter-day precisions (% RSD) for the relative retention times were both less than 1% for

  7. Critical ionisation velocity effects in astrophysical plasmas

    International Nuclear Information System (INIS)

    Raadu, M.A.

    1979-08-01

    Critical ionisation velocity effects are relevant to astrophysical situations where neutral gas moves through a magnetised plasma. The experimental significance of the critical velocity is well established and the physical basis is now becoming clear. The underlying mechanism depends on the combined effects of electron impact ionisation and electron energisation by collective plasma interactions. For low density plasmas a theory based on a circular process involving electron heating through a modified two stream instability has been developed. Several applications of critical velocity effects to astrophysical plasmas have been discussed in the literature. The importance of the effect in any particular case may be determined from a detailed consideration of energy and momentum balance, using appropriate atomic rate coefficients and taking full account of collective plasma processes. (Auth.)

  8. Laser mass spectrometry of chemical warfare agents using ultrashort laser pulses

    International Nuclear Information System (INIS)

    Weickhardt, C.; Grun, C.; Grotemeyer, J.

    1998-01-01

    Fast relaxation processes in excited molecules such as IC, ISC, and fragmentation are observed in many environmentally and technically relevant substances. They cause severe problems to resonance ionization mass spectrometry because they reduce the ionization yield and lead to mass spectra which do not allow the identification of the compound. By the use of ultrashort laser pulses these problems can be overcome and the advantages of REMPI over conventional ionization techniques in mass spectrometry can be regained. This is demonstrated using soil samples contaminated with a chemical warfare agent

  9. Non-equilibrium mass transfer absorption model for the design of boron isotopes chemical exchange column

    International Nuclear Information System (INIS)

    Bai, Peng; Fan, Kaigong; Guo, Xianghai; Zhang, Haocui

    2016-01-01

    Highlights: • We propose a non-equilibrium mass transfer absorption model instead of a distillation equilibrium model to calculate boron isotopes separation. • We apply the model to calculate the needed column height to meet prescribed separation requirements. - Abstract: To interpret the phenomenon of chemical exchange in boron isotopes separation accurately, the process is specified as an absorption–reaction–desorption hybrid process instead of a distillation equilibrium model, the non-equilibrium mass transfer absorption model is put forward and a mass transfer enhancement factor E is introduced to find the packing height needed to meet the specified separation requirements with MATLAB.

  10. Mass Spectrometric Analysis of Eight Common Chemical Explosives Using Ion Trap Mass Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sehwan; Lee, Jihyeon; KIm, Jeongkwon [Chungnam National Univ., Daejeon (Korea, Republic of); Cho, Soo Gyeong; Goh, Eun Mee [Agency for Defense Development, Daejeon (Korea, Republic of); Lee, Sungman; Koh, Sungsuk [Sensor Tech Inc., Seoul (Korea, Republic of)

    2013-12-15

    Eight representative explosives (ammonium perchlorate (AP), ammonium nitrate (AN), trinitrotoluene (TNT), 2,4-dinitrotoluene (DNT), cyclonite (RDX), cyclotetramethylenetetranitramine (HMX), pentaerythritol tetranitrate (PETN), and hexanitrostilbene (HNS)) were comprehensively analyzed with an ion trap mass spectrometer in negative ion mode using direct infusion electrospray ionization. MS/MS experiments were performed to generate fragment ions from the major parent ion of each explosive. Explosives in salt forms such as AP or AN provided cluster parent ions with their own anions. Explosives with an aromatic ring were observed as either [M.H]{sup -} for TNT and DNT or [M]{sup ·-}. for HNS, while explosives without an aromatic ring such as RDX, HMX, and PETN were detected as an adduct ion with a formate anion, i. e., [M+HCOO]{sup -}. These findings provide a guideline for the rapid and accurate detection of explosives once portable MS instruments become more readily available.

  11. Mass Spectrometric Analysis of Eight Common Chemical Explosives Using Ion Trap Mass Spectrometer

    International Nuclear Information System (INIS)

    Park, Sehwan; Lee, Jihyeon; KIm, Jeongkwon; Cho, Soo Gyeong; Goh, Eun Mee; Lee, Sungman; Koh, Sungsuk

    2013-01-01

    Eight representative explosives (ammonium perchlorate (AP), ammonium nitrate (AN), trinitrotoluene (TNT), 2,4-dinitrotoluene (DNT), cyclonite (RDX), cyclotetramethylenetetranitramine (HMX), pentaerythritol tetranitrate (PETN), and hexanitrostilbene (HNS)) were comprehensively analyzed with an ion trap mass spectrometer in negative ion mode using direct infusion electrospray ionization. MS/MS experiments were performed to generate fragment ions from the major parent ion of each explosive. Explosives in salt forms such as AP or AN provided cluster parent ions with their own anions. Explosives with an aromatic ring were observed as either [M.H] - for TNT and DNT or [M] ·- . for HNS, while explosives without an aromatic ring such as RDX, HMX, and PETN were detected as an adduct ion with a formate anion, i. e., [M+HCOO] - . These findings provide a guideline for the rapid and accurate detection of explosives once portable MS instruments become more readily available

  12. Medical response to effects of ionising radiation

    International Nuclear Information System (INIS)

    Crosbie, W.A.; Gittus, J.H.

    1989-01-01

    The proceedings of a conference on 'Medical Response to Effects of Ionising Radiation' in 1989 in the form of nineteen papers published as a book. Topics discussed include radiation accidents at nuclear facilities, the medical management of radiation casualties, the responsibilities, plans and resources for coping with a nuclear accident and finally the long term effects of radiation, including leukaemia epidemiology studies. All papers were selected and indexed separately. (UK)

  13. A coupled theory for chemically active and deformable solids with mass diffusion and heat conduction

    Science.gov (United States)

    Zhang, Xiaolong; Zhong, Zheng

    2017-10-01

    To analyse the frequently encountered thermo-chemo-mechanical problems in chemically active material applications, we develop a thermodynamically-consistent continuum theory of coupled deformation, mass diffusion, heat conduction and chemical reaction. Basic balance equations of force, mass and energy are presented at first, and then fully coupled constitutive laws interpreting multi-field interactions and evolving equations governing irreversible fluxes are constructed according to the energy dissipation inequality and the chemical kinetics. To consider the essential distinction between mass diffusion and chemical reactions in affecting free energy and dissipations of a highly coupled system, we regard both the concentrations of diffusive species and the extent of reaction as independent state variables. This new formulation then distinguishes between the energy contribution from the diffusive species entering the solid and that from the subsequent chemical reactions occurring among these species and the host solid, which not only interact with stresses or strains in different manners and on different time scales, but also induce different variations of solid microstructures and material properties. Taking advantage of this new description, we further establish a specialized isothermal model to predict precisely the transient chemo-mechanical response of a swelling solid with a proposed volumetric constraint that accounts for material incompressibility. Coupled kinetics is incorporated to capture the volumetric swelling of the solid caused by imbibition of external species and the simultaneous dilation arised from chemical reactions between the diffusing species and the solid. The model is then exemplified with two numerical examples of transient swelling accompanied by chemical reaction. Various ratios of characteristic times of diffusion and chemical reaction are taken into account to shed light on the dependency on kinetic time scales of evolution patterns for

  14. Antioxidant Protection in Blood against Ionising Radiation

    International Nuclear Information System (INIS)

    Bognar, G.; Meszaros, G.; Koteles, G. J.

    2001-01-01

    Full text: The quantities of the antioxidants in the human blood are important indicators of health status. The routine determinations of activities/capacities of antioxidant compounds would be of great importance in assessing individual sensitivities against oxidative effects. We have investigated the sensitivities of those antioxidant elements against various doses of ionising radiation tested by the RANDOX assays. Our results show dose-dependent decreases of antioxidant activities caused by the different doses. The total antioxidant status value linearly decreased up to 1 Gy, but further increase of dose (2 Gy) did not influence the respective values although the test system still indicated their presence. It means that the human blood retains 60-70% of its total antioxidant capacity. Radiation induced alterations of the antioxidant enzymes: glutathione peroxidase and superoxide dismutase have been also investigated. The activities of glutathione peroxidase and superoxide dismutase decreased linearly upon the effects of various doses of ionising radiation till 1 Gy. Between 1 and 2 Gy only further mild decreases could be detected. In this case the human blood retained 40-60% of these two antioxidant enzymes. These observations suggest either the limited response of antioxidant system against ionising radiation, or the existence of protection system of various reactabilities. (author)

  15. Heterogeneous chemical kinetics by modulated molecular beam mass spectrometry: limitations of technique

    International Nuclear Information System (INIS)

    Olander, D.R.

    1977-01-01

    The advantages and limitations of modulated molecular beam, mass spectrometry as applied to the study of heterogeneous chemical kinetics are reviewed. The process of deducing a model of the surface reaction from experimental data is illustrated by analysis of the hydrogen reduction of uranium dioxide

  16. On the Mathematical Structure of Balanced Chemical Reaction Networks Governed by Mass Action Kinetics

    NARCIS (Netherlands)

    Schaft, Arjan van der; Rao, Shodhan; Jayawardhana, Bayu

    2013-01-01

    Motivated by recent progress on the interplay between graph theory, dynamics, and systems theory, we revisit the analysis of chemical reaction networks described by mass action kinetics. For reaction networks possessing a thermodynamic equilibrium we derive a compact formulation exhibiting at the

  17. Variable elimination in chemical reaction networks with mass-action kinetics

    DEFF Research Database (Denmark)

    Feliu, Elisenda; Wiuf, C.

    2012-01-01

    We consider chemical reaction networks taken with mass-action kinetics. The steady states of such a system are solutions to a system of polynomial equations. Even for small systems the task of finding the solutions is daunting. We develop an algebraic framework and procedure for linear elimination...

  18. On the graph and systems analysis of reversible chemical reaction networks with mass action kinetics

    NARCIS (Netherlands)

    Rao, Shodhan; Jayawardhana, Bayu; Schaft, Arjan van der

    2012-01-01

    Motivated by the recent progresses on the interplay between the graph theory and systems theory, we revisit the analysis of reversible chemical reaction networks described by mass action kinetics by reformulating it using the graph knowledge of the underlying networks. Based on this formulation, we

  19. Robust automated mass spectra interpretation and chemical formula calculation using mixed integer linear programming.

    Science.gov (United States)

    Baran, Richard; Northen, Trent R

    2013-10-15

    Untargeted metabolite profiling using liquid chromatography and mass spectrometry coupled via electrospray ionization is a powerful tool for the discovery of novel natural products, metabolic capabilities, and biomarkers. However, the elucidation of the identities of uncharacterized metabolites from spectral features remains challenging. A critical step in the metabolite identification workflow is the assignment of redundant spectral features (adducts, fragments, multimers) and calculation of the underlying chemical formula. Inspection of the data by experts using computational tools solving partial problems (e.g., chemical formula calculation for individual ions) can be performed to disambiguate alternative solutions and provide reliable results. However, manual curation is tedious and not readily scalable or standardized. Here we describe an automated procedure for the robust automated mass spectra interpretation and chemical formula calculation using mixed integer linear programming optimization (RAMSI). Chemical rules among related ions are expressed as linear constraints and both the spectra interpretation and chemical formula calculation are performed in a single optimization step. This approach is unbiased in that it does not require predefined sets of neutral losses and positive and negative polarity spectra can be combined in a single optimization. The procedure was evaluated with 30 experimental mass spectra and was found to effectively identify the protonated or deprotonated molecule ([M + H](+) or [M - H](-)) while being robust to the presence of background ions. RAMSI provides a much-needed standardized tool for interpreting ions for subsequent identification in untargeted metabolomics workflows.

  20. Effects of Main-Sequence Mass Loss on Stellar and Galactic Chemical Evolution.

    Science.gov (United States)

    Guzik, Joyce Ann

    1988-06-01

    L. A. Willson, G. H. Bowen and C. Struck -Marcell have proposed that 1 to 3 solar mass stars may experience evolutionarily significant mass loss during the early part of their main-sequence phase. The suggested mass-loss mechanism is pulsation, facilitated by rapid rotation. Initial mass-loss rates may be as large as several times 10^{-9}M o/yr, diminishing over several times 10^8 years. We attempted to test this hypothesis by comparing some theoretical implications with observations. Three areas are addressed: Solar models, cluster HR diagrams, and galactic chemical evolution. Mass-losing solar models were evolved that match the Sun's luminosity and radius at its present age. The most extreme viable models have initial mass 2.0 M o, and mass-loss rates decreasing exponentially over 2-3 times 10^8 years. Compared to a constant -mass model, these models require a reduced initial ^4He abundance, have deeper envelope convection zones and higher ^8B neutrino fluxes. Early processing of present surface layers at higher interior temperatures increases the surface ^3He abundance, destroys Li, Be and B, and decreases the surface C/N ratio following first dredge-up. Evolution calculations incorporating main-sequence mass loss were completed for a grid of models with initial masses 1.25 to 2.0 Mo and mass loss timescales 0.2 to 2.0 Gyr. Cluster HR diagrams synthesized with these models confirm the potential for the hypothesis to explain observed spreads or bifurcations in the upper main sequence, blue stragglers, anomalous giants, and poor fits of main-sequence turnoffs by standard isochrones. Simple closed galactic chemical evolution models were used to test the effects of main-sequence mass loss on the F and G dwarf distribution. Stars between 3.0 M o and a metallicity -dependent lower mass are assumed to lose mass. The models produce a 30 to 60% increase in the stars to stars-plus -remnants ratio, with fewer early-F dwarfs and many more late-F dwarfs remaining on the main

  1. ANALYSIS AND IDENTIFICATION SPIKING CHEMICAL COMPOUNDS RELATED TO CHEMICAL WEAPON CONVENTION IN UNKNOWN WATER SAMPLES USING GAS CHROMATOGRAPHY AND GAS CHROMATOGRAPHY ELECTRON IONIZATION MASS SPECTROMETRY

    Directory of Open Access Journals (Sweden)

    Harry Budiman

    2010-06-01

    Full Text Available The identification and analysis of chemical warfare agents and their degradation products is one of important component for the implementation of the convention. Nowadays, the analytical method for determination chemical warfare agent and their degradation products has been developing and improving. In order to get the sufficient analytical data as recommended by OPCW especially in Proficiency Testing, the spiking chemical compounds related to Chemical Weapon Convention in unknown water sample were determined using two different techniques such as gas chromatography and gas chromatography electron-impact ionization mass spectrometry. Neutral organic extraction, pH 11 organic extraction, cation exchanged-methylation, triethylamine/methanol-silylation were performed to extract the chemical warfare agents from the sample, before analyzing with gas chromatography. The identification of chemical warfare agents was carried out by comparing the mass spectrum of chemicals with mass spectrum reference from the OPCW Central Analytical Database (OCAD library while the retention indices calculation obtained from gas chromatography analysis was used to get the confirmation and supported data of  the chemical warfare agents. Diisopropyl methylphosphonate, 2,2-diphenyl-2-hydroacetic acid and 3-quinuclidinol were found in unknown water sample. Those chemicals were classified in schedule 2 as precursor or reactant of chemical weapons compound in schedule list of Chemical Weapon Convention.   Keywords: gas chromatography, mass spectrometry, retention indices, OCAD library, chemical warfare agents

  2. Real time monitoring of accelerated chemical reactions by ultrasonication-assisted spray ionization mass spectrometry.

    Science.gov (United States)

    Lin, Shu-Hsuan; Lo, Ta-Ju; Kuo, Fang-Yin; Chen, Yu-Chie

    2014-01-01

    Ultrasonication has been used to accelerate chemical reactions. It would be ideal if ultrasonication-assisted chemical reactions could be monitored by suitable detection tools such as mass spectrometry in real time. It would be helpful to clarify reaction intermediates/products and to have a better understanding of reaction mechanism. In this work, we developed a system for ultrasonication-assisted spray ionization mass spectrometry (UASI-MS) with an ~1.7 MHz ultrasonic transducer to monitor chemical reactions in real time. We demonstrated that simply depositing a sample solution on the MHz-based ultrasonic transducer, which was placed in front of the orifice of a mass spectrometer, the analyte signals can be readily detected by the mass spectrometer. Singly and multiply charged ions from small and large molecules, respectively, can be observed in the UASI mass spectra. Furthermore, the ultrasonic transducer used in the UASI setup accelerates the chemical reactions while being monitored via UASI-MS. The feasibility of using this approach for real-time acceleration/monitoring of chemical reactions was demonstrated. The reactions of Girard T reagent and hydroxylamine with steroids were used as the model reactions. Upon the deposition of reactant solutions on the ultrasonic transducer, the intermediate/product ions are readily generated and instantaneously monitored using MS within 1 s. Additionally, we also showed the possibility of using this reactive UASI-MS approach to assist the confirmation of trace steroids from complex urine samples by monitoring the generation of the product ions. Copyright © 2014 John Wiley & Sons, Ltd.

  3. Ozone mass transfer behaviors on physical and chemical absorption for hollow fiber membrane contactors.

    Science.gov (United States)

    Zhang, Yong; Li, Kuiling; Wang, Jun; Hou, Deyin; Liu, Huijuan

    2017-09-01

    To understand the mass transfer behaviors in hollow fiber membrane contactors, ozone fluxes affected by various conditions and membranes were investigated. For physical absorption, mass transfer rate increased with liquid velocity and the ozone concentration in the gas. Gas flow rate was little affected when the velocity was larger than the critical value, which was 6.1 × 10 -3 m/s in this study. For chemical absorption, the flux was determined by the reaction rate between ozone and the absorbent. Therefore, concentration, species, and pH affected the mass transfer process markedly. For different absorbents, the order of mass transfer rate was the same as the reaction rate constant, which was phenol, sodium nitrite, hydrogen peroxide, and oxalate. Five hydrophobic membranes with various properties were employed and the mass transfer behavior can be described by the Graetz-Lévèque equation for the physical absorption process. The results showed the process was controlled by liquid film and the gas phase conditions, and membrane properties did not affect the ozone flux. For the chemical absorption, gas film, membrane and liquid film affected the mass transfer together, and none of them were negligible.

  4. Food ionisation. Realities and perspectives; L'ionisation alimentaire. Realites et perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Bonnet, G

    1994-06-01

    The ionisation of food is a treatment using a certain type of energy. the radiations used in the industrial treatments are limited to three sources. The gamma radiations, the x radiations and the electrons beams emitted with accelerators. The physical treatments by ionizing radiations have for aim to cleanse and to increase the conservation time of food. Now, the applications in agriculture and food industry, are still marginal. The industrial using ionisation are these ones that did not find any alternative decontamination method. The barriers are more scientific or technical or economical than a question of regulation or behaviour. (N.C.)

  5. Food ionisation. Realities and perspectives; L'ionisation alimentaire. Realites et perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Bonnet, G

    1994-06-01

    The ionisation of food is a treatment using a certain type of energy. the radiations used in the industrial treatments are limited to three sources. The gamma radiations, the x radiations and the electrons beams emitted with accelerators. The physical treatments by ionizing radiations have for aim to cleanse and to increase the conservation time of food. Now, the applications in agriculture and food industry, are still marginal. The industrial using ionisation are these ones that did not find any alternative decontamination method. The barriers are more scientific or technical or economical than a question of regulation or behaviour. (N.C.)

  6. The ionisation balance of C0 to C+4

    International Nuclear Information System (INIS)

    Nussbaumer, H.; Storey, P.J.

    1975-01-01

    The ionisation balance for the ions C 0 -C +4 has been calculated for 10 8 -3 ] 12 and 2 x 10 4 K 5 K. The presence of metastable terms is included in the calculation of the collisional dielectronic recombination and ionisation coefficients. The influence of the observed solar radiation field on the ionisation balance is investigated. Changes in that field do strongly influence the results. (orig.) [de

  7. Chemical Evolution of Groundwater Near a Sinkhole Lake, Northern Florida: 2. Chemical Patterns, Mass Transfer Modeling, and Rates of Mass Transfer Reactions

    Science.gov (United States)

    Katz, Brian G.; Plummer, L. Niel; Busenberg, Eurybiades; Revesz, Kinga M.; Jones, Blair F.; Lee, Terrie M.

    1995-06-01

    Chemical patterns along evolutionary groundwater flow paths in silicate and carbonate aquifers were interpreted using solute tracers, carbon and sulfur isotopes, and mass balance reaction modeling for a complex hydrologic system involving groundwater inflow to and outflow from a sinkhole lake in northern Florida. Rates of dominant reactions along defined flow paths were estimated from modeled mass transfer and ages obtained from CFC-modeled recharge dates. Groundwater upgradient from Lake Barco remains oxic as it moves downward, reacting with silicate minerals in a system open to carbon dioxide (CO2), producing only small increases in dissolved species. Beneath and downgradient of Lake Barco the oxic groundwater mixes with lake water leakage in a highly reducing, silicate-carbonate mineral environment. A mixing model, developed for anoxic groundwater downgradient from the lake, accounted for the observed chemical and isotopic composition by combining different proportions of lake water leakage and infiltrating meteoric water. The evolution of major ion chemistry and the 13C isotopic composition of dissolved carbon species in groundwater downgradient from the lake can be explained by the aerobic oxidation of organic matter in the lake, anaerobic microbial oxidation of organic carbon, and incongruent dissolution of smectite minerals to kaolinite. The dominant process for the generation of methane was by the CO2 reduction pathway based on the isotopic composition of hydrogen (δ2H(CH4) = -186 to -234‰) and carbon (δ13C(CH4) = -65.7 to -72.3‰). Rates of microbial metabolism of organic matter, estimated from the mass transfer reaction models, ranged from 0.0047 to 0.039 mmol L-1 yr-1 for groundwater downgradient from the lake.

  8. [In-hospital management of victims of chemical weapons of mass destruction].

    Science.gov (United States)

    Barelli, Alessandro; Gargano, Flavio; Proietti, Rodolfo

    2005-01-01

    Emergency situations caused by chemical weapons of mass destruction add a new dimension of risk to those handling and treating casualties. The fundamental difference between a hazardous materials incident and conventional emergencies is the potential for risk from contamination to health care professionals, patients, equipment and facilities of the Emergency Department. Accurate and specific guidance is needed to describe the procedures to be followed by emergency medical personnel to safely care for a patient, as well as to protect equipment and people. This review is designed to familiarize readers with the concepts, terminology and key operational considerations that affect the in-hospital management of incidents by chemical weapons.

  9. Heat and mass transfer for turbulent flow of chemically reacting gas in eccentric annular channels

    International Nuclear Information System (INIS)

    Besedina, T.V.; Tverkovkin, B.E.; Udot, A.V.; Yakushev, A.P.

    1988-01-01

    Because of the possibility of using dissociating gases as coolants and working bodies of nuclear power plants, it is necessary to develop computational algorithms for calculating heat and mass transfer processes under conditions of nonequilibrium flow of chemically reacting gases not only in axisymmetric channels, but also in channels with a complex transverse cross section (including also in eccentric annular channels). An algorithm is proposed for calculating the velocity, temperature, and concentration fields under conditions of cooling of a cylindrical heat-releasing rod, placed off-center in a circular casing pipe, by a longitudinal flow of chemically reacting gas [N 2 O 4

  10. Chemical effect on total mass attenuation coefficients of V, Cr, Mn, Co and Ni

    International Nuclear Information System (INIS)

    Soeguet, Oe.; Colak, S.; Bueyuekkasap, E.; Kuecuekoender, A.

    2002-01-01

    Detailed interpretation of data obtained from X-ray transmission measurements usually depends on the assumption that the contribution of each element is additive. This assumption yields the mixture rule for X-ray attenuation coefficients which is valid if molecular and chemical effects are negligible. Total mass attenuation coefficients of V, Cr, Mn, Co and Ni in various their compounds was measured. Absorption corrections were carried on data for ligands in the compounds. It was found that V, Cr, Mn, Co and Ni had different total mass attenuation coefficients in the different compounds. Results were compared with theoretical values of HUBBELL and SELTZER. (author)

  11. The use of the dusty-gas model for the description of mass transport with chemical reaction in porous media

    NARCIS (Netherlands)

    Veldsink, J.W.; Veldsink, J.W.; van Damme, Rudolf M.J.; Versteeg, Geert; van Swaaij, Willibrordus Petrus Maria

    1995-01-01

    In the present study, mass transport accompanied by chemical reactions in porous media is studied according to the Fick model and the dusty-gas model. For mass transport accompanied by a chemical reaction in catalyst structures showing a plane, line, or point of symmetry, the approximate analytical

  12. Properties of an ionised-cluster beam from a vaporised-cluster ion source

    International Nuclear Information System (INIS)

    Takagi, T.; Yamada, I.; Sasaki, A.

    1978-01-01

    A new type of ion source vaporised-metal cluster ion source, has been developed for deposition and epitaxy. A cluster consisting of 10 2 to 10 3 atoms coupled loosely together is formed by adiabatic expansion ejecting the vapour of materials into a high-vacuum region through the nozzle of a heated crucible. The clusters are ionised by electron bombardment and accelerated with neutral clusters toward a substrate. In this paper, mechanisms of cluster formation experimental results of the cluster size (atoms/cluster) and its distribution, and characteristics of the cluster ion beams are reported. The size is calculated from the kinetic equation E = (1/2)mNVsub(ej) 2 , where E is the cluster beam energy, Vsub(ej) is the ejection velocity, m is the mass of atom and N is the cluster size. The energy and the velocity of the cluster are measured by an electrostatic 127 0 energy analyser and a rotating disc system, respectively. The cluster size obtained for Ag is about 5 x 10 2 to 2 x 10 3 atoms. The retarding potential method is used to confirm the results for Ag. The same dependence on cluster size for metals such as Ag, Cu and Pb has been obtained in previous experiments. In the cluster state the cluster ion beam is easily produced by electron bombardment. About 50% of ionised clusters are obtained under typical operation conditions, because of the large ionisation cross sections of the clusters. To obtain a uniform spatial distribution, the ionising electrode system is also discussed. The new techniques are termed ionised-cluster beam deposition (ICBD) and epitaxy (ICBE). (author)

  13. Ionising energy treatment of fresh fruit

    International Nuclear Information System (INIS)

    Rigney, C.J.

    1985-01-01

    The main purposes of the ionising energy treatment of fresh fruit are: the extension of shelf life of the commodity due to a direct physiological effect on the particular product; the extension of shelf life of the commodity due to a reduction in the development of moulds and rots which would normally render the product worthless; and the killing of insect pests of quarantine significance, to allow for normal marketing of fresh fruit without the risk of introducing insect pests to previously pest-free areas

  14. The ionisation equation in a relativistic gas

    International Nuclear Information System (INIS)

    Kichenassamy, S.; Krikorian, R.A.

    1983-01-01

    By deriving the relativistic form of the ionisation equation for a perfect gas it is shown that the usual Saha equation is valid to 3% for temperatures below one hundred million Kelvin. Beyond 10 9 K, the regular Saha equation is seriously incorrect and a relativistic distribution function for electrons must be taken into account. Approximate forms are derived when only the electrons are relativistic (appropriate up to 10 12 K) and also for the ultrarelativistic case (temperatures greater than 10 15 K). (author)

  15. Ionising radiation: a guide to the Regulations

    International Nuclear Information System (INIS)

    Hughes, Donald.

    1986-01-01

    The author explains the basic requirements on health and safety personnel in relation to the Ionising Radiations Regulations 1985. The outline paper is presented under the following headings: Dose assessment, Interpretation and general regulations 1-5, Dose limitation regulations 6 and 7, Regulation of work - regulations 8-12, Dosimetry and medical surveillance - regulations 13-17, summary of records to be kept, entry to controlled areas, Control of radioactive substances -regulations 18-23, Monitoring of radiation regulation 24, Assessments and notifications - regulations 25-31, Safety of articles and equipment - regulations 32-34, Other guidance. (U.K.)

  16. Re-discovering surface mass spectrometry: chemical mapping from micro to macro

    Energy Technology Data Exchange (ETDEWEB)

    Lloyd, K.G.; O' Keefe, D.P

    2004-06-15

    New developments in electronics, devices, micro-encapsulation, and other areas demand the ability to acquire molecularly-specific information from smaller and smaller features. ToF-SIMS provides molecularly-specific mass spectral data, but sufficient high-mass signal has historically been difficult to obtain from organic/polymeric surfaces in the point-mapping mode of operation. Use of chemometric data reduction methods and the development of heavier primary ion sources enhance and extend the chemical information in the mapping data. Large-area chemical mapping via sample stage rastering has also opened up new applications. This capability allows single-experiment mapping of large or multiple features, provides information on surface uniformity over end-use-relevant areas, and offers potential for combinatorial and other screening applications. Examples of these applications are presented.

  17. Effect of mass loss on the chemical yields from massive stars

    Energy Technology Data Exchange (ETDEWEB)

    Chiosi, C; Caimmi, R [Padua Univ. (Italy). Istituto di Astronomia

    1979-01-01

    Recent results on the calculation of the chemical yields from massive stars, are rediscussed by taking into account the occurrence of mass loss by stellar wind during the core H- and He-burning phases. The new yields are found to be compatible with the observed distribution of chemical abundances in the solar system, except for He. The net enrichment of several elements over the galaxy's lifetime is found to be consistent with the current estimate of the star formation rate, if we adopt a two phase process of galaxy formation (halodisk). The relative He to heavy element enrichment rate ..delta..Y/..delta..Z turns out to agree with the observational value when mass loss by stellar wind is taken into account.

  18. Ultrasensitive detection of explosives and chemical warfare agents by low-pressure photoionization mass spectrometry.

    Science.gov (United States)

    Sun, Wanqi; Liang, Miao; Li, Zhen; Shu, Jinian; Yang, Bo; Xu, Ce; Zou, Yao

    2016-08-15

    On-spot monitoring of threat agents needs high sensitive instrument. In this study, a low-pressure photoionization mass spectrometer (LPPI-MS) was employed to detect trace amounts of vapor-phase explosives and chemical warfare agent mimetics under ambient conditions. Under 10-s detection time, the limits of detection of 2,4-dinitrotoluene, nitrotoluene, nitrobenzene, and dimethyl methyl phosphonate were 30, 0.5, 4, and 1 parts per trillion by volume, respectively. As compared to those obtained previously with PI mass spectrometric techniques, an improvement of 3-4 orders of magnitude was achieved. This study indicates that LPPI-MS will open new opportunities for the sensitive detection of explosives and chemical warfare agents. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Organic-Chemical Clues to the Theory of Impacts as a Cause of Mass Extinctions

    Science.gov (United States)

    Sack, N. J.

    1988-11-01

    The reasons for the mass extinctions, which occur from time to time in Earth's history-as, e.g., the dinosaur extinction at the Cretaceous/Tertiary boundary 65 myr ago - are still not satisfactorily cleared up. A possible reason might be the impact of one or several comets of several kilometers in diameter. In this paper the astrophysical background of this hypothesis and organic-chemical processes during an impact will be discussed. Quantitative estimations are given, which show that the amount of organic substances brought to the Earth may be of the same order of magnitude as the normal biological production of organic material. Investigations are proposed to examine the organic-chemical composition of profiles of the Cretaceous/Tertiary boundary and other boundaries, at which mass extinction had occurred, in order to find anomalies as consequences of impacts.

  20. Chemical modification of DNA: Molecular specificity studied by tandem mass spectrometry and liquid chromatography

    International Nuclear Information System (INIS)

    Chang, Ching-jer; Cooks, R.G.; Chae, Whi-Gun; Wood, J.M.

    1989-01-01

    Chemical modifications of DNA in vitro could be directly studied by C-13 NMR and P-31 NMR, which eliminated all degradation and separation processes. The prospects of utilized the NMR method in the in vitro experiments are limited because of the inherent low sensitivity of NMR and low level of DNA modification. We have developed a reverse-phase ion-paired HPLC method to study DNA modifications by methylating agents. The structural specificity of HPLC is significantly enhanced by conjunction with the specificity of enzymic transformations. The HPLC studies have also revealed the limitation of HPLC method for simultaneous determination of many minor modified nucleosides. This problem has been overcome by tandem mass spectrometry. In conjunction with the resolving power of HPLC in separating isomers, desorption chemical ionization tandem mass spectrometry has been utilized in the determination of the modified nucleosides at the picomole level using stable-isotope labeled compounds as internal references

  1. Method for the elucidation of the elemental composition of low molecular mass chemicals using exact masses of product ions and neutral losses: application to environmental chemicals measured by liquid chromatography with hybrid quadrupole/time-of-flight mass spectrometry.

    Science.gov (United States)

    Suzuki, Shigeru; Ishii, Tetsuko; Yasuhara, Akio; Sakai, Shinichi

    2005-01-01

    A method for elucidating the elemental compositions of low molecular weight chemicals, based primarily on mass measurements made using liquid chromatography (LC) with time-of-flight mass spectrometry (TOFMS) and quadrupole/time-of-flight mass spectrometry (LC/QTOFMS), was developed and tested for 113 chemicals of environmental interest with molecular masses up to approximately 400 Da. As the algorithm incorporating the method is not affected by differences in the instrument used, or by the ionization method and other ionization conditions, the method is useful not only for LC/TOFMS, but also for all kinds of mass spectra measured with higher accuracy and precision (uncertainties of a few mDa) employing all ionization methods and on-line separation techniques. The method involves calculating candidate compositions for intact ionized molecules (ionized forms of the sample molecule that have lost or gained no more than a proton, i.e., [M+H](+) or [M-H](-)) as well as for fragment ions and corresponding neutral losses, and eliminating those atomic compositions for the molecules that are inconsistent with the corresponding candidate compositions of fragment ions and neutral losses. Candidate compositions were calculated for the measured masses of the intact ionized molecules and of the fragment ions and corresponding neutral losses, using mass uncertainties of 2 and 5 mDa, respectively. Compositions proposed for the ionized molecule that did not correspond to the sum of the compositions of a candidate fragment ion and its corresponding neutral loss were discarded. One, 2-5, 6-10, 11-20, and >20 candidate compositions were found for 65%, 39%, 1%, 1%, and 0%, respectively, for the 124 ionized molecules formed from the 113 chemicals tested (both positive and negative ions were obtained from 11 of the chemicals). However, no candidate composition was found for 2% of the test cases (i.e., 3 chemicals), for each of which the measured mass of one of the product ions was in

  2. INAA application in the assessment of chemical element mass fractions in adult and geriatric prostate glands

    International Nuclear Information System (INIS)

    Zaichick, Vladimir; Zaichick, Sofia

    2014-01-01

    The variation with age of the mass fraction of 37 chemical elements in intact nonhyperplastic prostate of 65 healthy 21–87 year old males was investigated by instrumental neutron activation analysis with high resolution spectrometry of short- and long-lived radionuclides. Mean values (M±SΕΜ) for mass fractions (mg kg −1 , dry mass basis) of the chemical elements studied were: Ag—0.055±0.007, Br—33.2±3.3, Ca—2150±118, Cl—13014±703, Co—0.038±0.003, Cr—0.47±0.05, Fe—99.3±6.1, Hg—0.044±0.006, K—11896±356, Mg—1149±68, Mn—1.41±0.07, Na—10886±339, Rb—12.3±0.6, Sb—0.049±0.005, Sc—0.021±0.003, Se—0.65±0.03, and Zn—795±71. The mass fraction of other chemical elements measured in this study were lower than the corresponding detection limits (mg kg −1 , dry mass basis): As<0.1, Au<0.01, Ba<100, Cd<2, Ce<0.1, Cs<0.05, Eu<0.001, Gd<0.02, Hf<0.2, La<0.5, Lu<0.003, Nd<0.1, Sm<0.01, Sr<3, Ta<0.01, Tb<0.03, Th<0.05, U<0.07, Yb<0.03, and Zr<0.3. This work revealed that there is a significant trend for increase with age in mass fractions of Co (p<0.0085), Fe (p<0.037), Hg (p<0.035), Sc (p<0.015), and Zn (p<0.0014) and for a decrease in the mass fraction of Mn (p<0.018) in prostates, obtained from young adult up to about 60 years, with age. In the nonhyperplastic prostates of males in the sixth to ninth decades, the magnitude of mass fractions of all chemical element were maintained at near constant levels. Our finding of correlation between the prostatic chemical element mass fractions indicates that there is a great variation of chemical element relationships with age. - Highlights: • 37 trace elements were determined in prostate of 65 healthy 21–87 year old males by NAA. • Co, Fe, Hg, Sc, and Zn contents significantly increase with age. • Mn content significantly decreases with age. • All elemental contents in the sixth to ninth decades are near constant level. • There is a great disturbance of chemical element

  3. Radioimmunoassay and chemical ionization/mass spectrometry compared for plasma cortisol determination

    International Nuclear Information System (INIS)

    Lindberg, C.; Johnson, S.; Hedner, P.; Gustafsson, A.

    1982-01-01

    A method is described for determination of cortisol in plasma and urine, based on chemical ionization/mass spectrometry with deuterium-labeled cortisol as the internal standard. The within-run precision (CV) was 2.5-5.7%, the between-run precision 4.6%. Results by this method were compared with those by a radioimmunological method (RIANEN Cortisol, New England Nuclear) for 395 plasma samples. The latter method gave significantly higher (approx. 25%) cortisol values

  4. CHEMICAL AND PHYSICAL CHARACTERIZATION OF COLLAPSING LOW-MASS PRESTELLAR DENSE CORES

    Energy Technology Data Exchange (ETDEWEB)

    Hincelin, U. [Department of Chemistry, University of Virginia, Charlottesville, VA 22904 (United States); Commerçon, B. [Ecole Normale Supérieure de Lyon, CRAL, UMR 5574 du CNRS, Université Lyon I, 46 Allée d’Italie, F-69364 Lyon cedex 07 (France); Wakelam, V.; Hersant, F.; Guilloteau, S. [Univ. Bordeaux, LAB, UMR 5804, F-33270, Floirac (France); Herbst, E., E-mail: ugo.hincelin@gmail.com [Departments of Chemistry and Astronomy, University of Virginia, Charlottesville, VA 22904 (United States)

    2016-05-01

    The first hydrostatic core, also called the first Larson core, is one of the first steps in low-mass star formation as predicted by theory. With recent and future high-performance telescopes, the details of these first phases are becoming accessible, and observations may confirm theory and even present new challenges for theoreticians. In this context, from a theoretical point of view, we study the chemical and physical evolution of the collapse of prestellar cores until the formation of the first Larson core, in order to better characterize this early phase in the star formation process. We couple a state-of-the-art hydrodynamical model with full gas-grain chemistry, using different assumptions for the magnetic field strength and orientation. We extract the different components of each collapsing core (i.e., the central core, the outflow, the disk, the pseudodisk, and the envelope) to highlight their specific physical and chemical characteristics. Each component often presents a specific physical history, as well as a specific chemical evolution. From some species, the components can clearly be differentiated. The different core models can also be chemically differentiated. Our simulation suggests that some chemical species act as tracers of the different components of a collapsing prestellar dense core, and as tracers of the magnetic field characteristics of the core. From this result, we pinpoint promising key chemical species to be observed.

  5. GoAmazon 2014/15 Thermal Desorption Chemical Ionization Mass Spectrometer (TDCIMS) Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Smith, JN [Univ. of California, Irvine, CA (United States)

    2016-04-01

    The Thermal Desorption Chemical Ionization Mass Spectrometer (TDCIMS) deployment to the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility T3 site in Manacapuru, Brazil, was motivated by two main scientific objectives of the Green Ocean Amazon (GoAmazon) 2014/15 field campaign. 1) Study the interactions between anthropogenic and biogenic emissions by determining important molecular species in ambient nanoparticles. To address this, TDCIMS data will be combined with coincident measurements such as gas-phase sulfuric acid to determine the contribution of sulfuric acid condensation to nucleation and growth. We can then compare that result to TDCIMS-derived nanoparticle composition to determine the fraction of growth that can be attributed to the uptake of organic compounds. The molecular composition of sampled particles will also be used to attribute specific chemical species and mechanisms to growth, such as the condensation of low-volatility species or the oligomerization of α-dicarbonyl compounds. 2) Determine the source of new ambient nanoparticles in the Amazon. The hypothesis prior to measurements was that potassium salts formed from the evaporation of primary particles emitted by fungal spores can provide a unique and important pathway for new particle production in the Amazon basin. To explore this hypothesis, the TDCIMS recorded the mass spectra of sampled ambient particles using a protonated water cluster Chemical Ionization Mass Spectrometer (CIMS). Laboratory tests performed using potassium salts show that the TDCIMS can detect potassium with high sensitivity with this technique.

  6. Leaf spray: direct chemical analysis of plant material and living plants by mass spectrometry.

    Science.gov (United States)

    Liu, Jiangjiang; Wang, He; Cooks, R Graham; Ouyang, Zheng

    2011-10-15

    The chemical constituents of intact plant material, including living plants, are examined by a simple spray method that provides real-time information on sugars, amino acids, fatty acids, lipids, and alkaloids. The experiment is applicable to various plant parts and is demonstrated for a wide variety of species. An electrical potential is applied to the plant and its natural sap, or an applied solvent generates an electrospray that carries endogenous chemicals into an adjacent benchtop or miniature mass spectrometer. The sharp tip needed to create a high electric field can be either natural (e.g., bean sprout) or a small nick can be cut in a leaf, fruit, bark, etc. Stress-induced changes in glucosinolates can be followed on the minute time scale in several plants, including potted vegetables. Differences in spatial distributions and the possibility of studying plant metabolism are demonstrated. © 2011 American Chemical Society

  7. Hypothesis for prediction of environmental stability of chemicals by mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tremolada, P; Di Guardo, A; Calamari, D; Davoli, E; Fanelli, R [Milan Univ. (Italy). Ist. di Entomologia Agraria Istituto di Ricerche Farmacologiche Mario Negri, Milan (Italy)

    1992-01-01

    The environmental persistence of organic chemicals is generally very hard to predict. In this work, the hypothesis of the use of fragmentation data in Mass Spectrometry (MS) as a possible 'stability index' of the molecules is presented. Since the fragmentation is determined by the thermodynamic properties of the molecules, it is possible to deduct information about the 'intrinsic stability' of a chemical. Such information can be used and correlated to predict the environmental degradability of a substance, especially referring to abiotic degradation. To study this relation, three different methods of measuring the fragmentation patterns are compared. All the methods show similar behaviour and one of them, in particular, shows a very good qualitative correlation between fragmentation data and persistence values found in literature. A possible 'stability index' for the quantitative prediction of the environmental degradation of a chemical is discussed.

  8. Atmospheric pressure chemical ionization of fluorinated phenols in atmospheric pressure chemical ionization mass spectrometry, tandem mass spectrometry, and ion mobility spectrometry

    Science.gov (United States)

    Eiceman, G. A.; Bergloff, J. F.; Rodriguez, J. E.; Munro, W.; Karpas, Z.

    1999-01-01

    Atmospheric pressure chemical ionization (APCI)-mass spectrometry (MS) for fluorinated phenols (C6H5-xFxOH Where x = 0-5) in nitrogen with Cl- as the reagent ion yielded product ions of M Cl- through ion associations or (M-H)- through proton abstractions. Proton abstraction was controllable by potentials on the orifice and first lens, suggesting that some proton abstraction occurs through collision induced dissociation (CID) in the interface region. This was proven using CID of adduct ions (M Cl-) with Q2 studies where adduct ions were dissociated to Cl- or proton abstracted to (M-H)-. The extent of proton abstraction depended upon ion energy and structure in order of calculated acidities: pentafluorophenol > tetrafluorophenol > trifluorophenol > difluorophenol. Little or no proton abstraction occurred for fluorophenol, phenol, or benzyl alcohol analogs. Ion mobility spectrometry was used to determine if proton abstraction reactions passed through an adduct intermediate with thermalized ions and mobility spectra for all chemicals were obtained from 25 to 200 degrees C. Proton abstraction from M Cl- was not observed at any temperature for phenol, monofluorophenol, or difluorophenol. Mobility spectra for trifluorophenol revealed the kinetic transformations to (M-H)- either from M Cl- or from M2 Cl- directly. Proton abstraction was the predominant reaction for tetra- and penta-fluorophenols. Consequently, the evidence suggests that proton abstraction occurs from an adduct ion where the reaction barrier is reduced with increasing acidity of the O-H bond in C6H5-xFxOH.

  9. Chemical Mass Shifts in a Digital Linear Ion Trap as Analytical Identity of o-, m-, and p-Xylene.

    Science.gov (United States)

    Sun, Lulu; Xue, Bing; Huang, Zhengxu; Cheng, Ping; Ma, Li; Ding, Li; Zhou, Zhen

    2018-07-01

    Chemical mass shifts between isomeric ions of o-, m-, and p-xylene were measured using a digital linear ion trap, and the directions and values of the shifts were found to be correlated to the collision cross sections of the isomers. Both forward and reverse scans were used and the chemical shifts for each pair of isomers in scans of opposite directions were in opposite signs. Using different voltage settings (namely the voltage dividing ratio-VDR) of the ion trap allows adding high order field components in the quadrupole field and results in larger chemical mass shifts. The differential chemical mass shift which combined the shifts from forward and reverse scans doubled the amount of chemical shift, e.g., 0.077 Th between o- and p-xylene, enough for identification of the type of isomer without using an additional ion mobility spectrometer. The feature of equal and opposite chemical mass shifts also allowed to null out the chemical mass shift by calculating the mean m/z value between the two opposite scans and remove or reduce the mass error caused by chemical mass shift. Graphical Abstract ᅟ.

  10. Chemical Mass Shifts in a Digital Linear Ion Trap as Analytical Identity of o-, m-, and p-Xylene

    Science.gov (United States)

    Sun, Lulu; Xue, Bing; Huang, Zhengxu; Cheng, Ping; Ma, Li; Ding, Li; Zhou, Zhen

    2018-04-01

    Chemical mass shifts between isomeric ions of o-, m-, and p-xylene were measured using a digital linear ion trap, and the directions and values of the shifts were found to be correlated to the collision cross sections of the isomers. Both forward and reverse scans were used and the chemical shifts for each pair of isomers in scans of opposite directions were in opposite signs. Using different voltage settings (namely the voltage dividing ratio-VDR) of the ion trap allows adding high order field components in the quadrupole field and results in larger chemical mass shifts. The differential chemical mass shift which combined the shifts from forward and reverse scans doubled the amount of chemical shift, e.g., 0.077 Th between o- and p-xylene, enough for identification of the type of isomer without using an additional ion mobility spectrometer. The feature of equal and opposite chemical mass shifts also allowed to null out the chemical mass shift by calculating the mean m/z value between the two opposite scans and remove or reduce the mass error caused by chemical mass shift. [Figure not available: see fulltext.

  11. Simultaneous detection of five different 2-hydroxyethyl-DNA adducts formed by ethylene oxide exposure, using a high-performance liquid chromatography/electrospray ionisation tandem mass spectrometry assay.

    Science.gov (United States)

    Tompkins, Elaine M; Jones, Donald J L; Lamb, John H; Marsden, Debbie A; Farmer, Peter B; Brown, Karen

    2008-01-01

    A method has been developed for the simultaneous detection and quantitation of five different 2-hydroxyethyl-DNA (HE-DNA) adducts that could be formed as a result of exposure to ethylene oxide (EO). In addition to the major N7-HE-guanine (N7-HEG) adducts this assay can also measure the less prevalent but potentially more biologically significant N1-HE-2'-deoxyadenosine (N1-HEdA), O(6)-HE-2'-deoxyguanosine (O(6)-HEdG), N(6)-HE-2'-deoxyadenosine (N(6)-HEdA) and N3-HE-2'-deoxyuridine adducts (N3-HEdU). The method involves the isolation of HE adducts from the unmodified nucleosides by either neutral thermal hydrolysis or enzymatic digestion, followed by high-performance liquid chromatographic (HPLC) purification, before detection and quantification by liquid chromatography tandem mass spectrometry (LC/MS/MS) using selective reaction monitoring (SRM). The limits of detection were in the range 0.5-25 fmol for each individual adduct, making this one of the most sensitive assays available for the detection of N7-HEG. To illustrate the possible applications of the assay, it has been employed in the measurement of endogenous/background and EO-induced HE adducts in a variety of DNA samples.

  12. Analytical technique to address terrorist threats by chemical weapons of mass destruction

    Science.gov (United States)

    Dempsey, Patrick M.

    1997-01-01

    Terrorism is no longer an issue without effect on the American mind. We now live with the same concerns and fears that have been commonplace in other developed and third world countries for a long time. Citizens of other countries have long lived with the specter of terrorism and now the U.S. needs to be concerned and prepared for terrorist activities.T he terrorist has the ability to cause great destructive effects by focusing their effort on unaware and unprepared civilian populations. Attacks can range from simple explosives to sophisticated nuclear, chemical and biological weapons. Intentional chemical releases of hazardous chemicals or chemical warfare agents pose a great threat because of their ready availability and/or ease of production, and their ability to cause widespread damage. As this battlefront changes from defined conflicts and enemies to unnamed terrorists, we must implement the proper analytical tools to provide a fast and efficient response. Each chemical uses in a terrorists weapon leaves behind a chemical signature that can be used to identify the materials involved and possibly lead investigators to the source and to those responsible. New tools to provide fast and accurate detection for battlefield chemical and biological agent attack are emerging. Gas chromatography/mass spectrometry (GC/MS) is one of these tools that has found increasing use by the military to respond to chemical agent attacks. As the technology becomes smaller and more portable, it can be used by law enforcement personnel to identify suspected terrorist releases and to help prepare the response; define contaminated areas for evacuation and safety concerns, identify the proper treatment of exposed or affected civilians, and suggest decontamination and cleanup procedures.

  13. Advancements in mass spectrometry for biological samples: Protein chemical cross-linking and metabolite analysis of plant tissues

    Energy Technology Data Exchange (ETDEWEB)

    Klein, Adam [Iowa State Univ., Ames, IA (United States)

    2015-01-01

    This thesis presents work on advancements and applications of methodology for the analysis of biological samples using mass spectrometry. Included in this work are improvements to chemical cross-linking mass spectrometry (CXMS) for the study of protein structures and mass spectrometry imaging and quantitative analysis to study plant metabolites. Applications include using matrix-assisted laser desorption/ionization-mass spectrometry imaging (MALDI-MSI) to further explore metabolic heterogeneity in plant tissues and chemical interactions at the interface between plants and pests. Additional work was focused on developing liquid chromatography-mass spectrometry (LC-MS) methods to investigate metabolites associated with plant-pest interactions.

  14. Ionising radiation and trans-generational instability

    International Nuclear Information System (INIS)

    Vrhovac, I.; Niksic, G.

    2007-01-01

    Indirect monitoring of the impact posed by ionising radiation to the genome instability of the descendants, consequent to the irradiation of one of their parents, boils down to the investigation of changes occurring exclusively in the mini-satellite loci of the cells constituting the gametal developmental line. The resultant mini-satellite mutations are expressed in their percentages, and equal to the ratio of the number of mutated alleles in that particular generation over the total number of alleles present. The impact of ionising radiation to the irradiated parent's offspring was first noticed on haematopoietic mouse stem-cells. Even though an irradiated cell of a female parent lacks any mutations whatsoever, daughter cells present with the increased mutation rates. The observed phenomenon of the so called trans-generational instability has been defined as the occurrence of mutations in the genome of individuals originating from the irradiated ancestors. Due to the aforementioned, one can conclude that these mutations need not be present in the irradiated parental cells, and do not necessarily vanish in the next few generations, but may result in the increase in mutation rates observed in the latter. The results of the investigations performed on the animal model, as well as of those carried out in human population, point to the occurrence of significant changes to be found on mini-satellite loci of the descending generation, while the mechanism underlying those changes hasn't been completely clarified yet, and, therefore, calls for the further investigation. (author)

  15. Chemical characteristics of submicron particles at the central Tibetan Plateau: insights from aerosol mass spectrometry

    Directory of Open Access Journals (Sweden)

    J. Xu

    2018-01-01

    Full Text Available Recent studies have revealed a significant influx of anthropogenic aerosol from South Asia to the Himalayas and Tibetan Plateau (TP during pre-monsoon period. In order to characterize the chemical composition, sources, and transport processes of aerosol in this area, we carried out a field study during June 2015 by deploying a suite of online instruments including an Aerodyne high-resolution time-of-flight aerosol mass spectrometer (HR-AMS and a multi-angle absorption photometer (MAAP at Nam Co station (90°57′ E, 30°46′ N; 4730 m a.s.l. at the central of the TP. The measurements were made at a period when the transition from pre-monsoon to monsoon occurred. The average ambient mass concentration of submicron particulate matter (PM1 over the whole campaign was  ∼  2.0 µg m−3, with organics accounting for 68 %, followed by sulfate (15 %, black carbon (8 %, ammonium (7 %, and nitrate (2 %. Relatively higher aerosol mass concentration episodes were observed during the pre-monsoon period, whereas persistently low aerosol concentrations were observed during the monsoon period. However, the chemical composition of aerosol during the higher aerosol concentration episodes in the pre-monsoon season was on a case-by-case basis, depending on the prevailing meteorological conditions and air mass transport routes. Most of the chemical species exhibited significant diurnal variations with higher values occurring during afternoon and lower values during early morning, whereas nitrate peaked during early morning in association with higher relative humidity and lower air temperature. Organic aerosol (OA, with an oxygen-to-carbon ratio (O ∕ C of 0.94, was more oxidized during the pre-monsoon period than during monsoon (average O ∕ C ratio of 0.72, and an average O ∕ C was 0.88 over the entire campaign period, suggesting overall highly oxygenated aerosol in the central TP. Positive matrix factorization of the

  16. Chemical characteristics of submicron particles at the central Tibetan Plateau: insights from aerosol mass spectrometry

    Science.gov (United States)

    Xu, Jianzhong; Zhang, Qi; Shi, Jinsen; Ge, Xinlei; Xie, Conghui; Wang, Junfeng; Kang, Shichang; Zhang, Ruixiong; Wang, Yuhang

    2018-01-01

    Recent studies have revealed a significant influx of anthropogenic aerosol from South Asia to the Himalayas and Tibetan Plateau (TP) during pre-monsoon period. In order to characterize the chemical composition, sources, and transport processes of aerosol in this area, we carried out a field study during June 2015 by deploying a suite of online instruments including an Aerodyne high-resolution time-of-flight aerosol mass spectrometer (HR-AMS) and a multi-angle absorption photometer (MAAP) at Nam Co station (90°57' E, 30°46' N; 4730 m a.s.l.) at the central of the TP. The measurements were made at a period when the transition from pre-monsoon to monsoon occurred. The average ambient mass concentration of submicron particulate matter (PM1) over the whole campaign was ˜ 2.0 µg m-3, with organics accounting for 68 %, followed by sulfate (15 %), black carbon (8 %), ammonium (7 %), and nitrate (2 %). Relatively higher aerosol mass concentration episodes were observed during the pre-monsoon period, whereas persistently low aerosol concentrations were observed during the monsoon period. However, the chemical composition of aerosol during the higher aerosol concentration episodes in the pre-monsoon season was on a case-by-case basis, depending on the prevailing meteorological conditions and air mass transport routes. Most of the chemical species exhibited significant diurnal variations with higher values occurring during afternoon and lower values during early morning, whereas nitrate peaked during early morning in association with higher relative humidity and lower air temperature. Organic aerosol (OA), with an oxygen-to-carbon ratio (O / C) of 0.94, was more oxidized during the pre-monsoon period than during monsoon (average O / C ratio of 0.72), and an average O / C was 0.88 over the entire campaign period, suggesting overall highly oxygenated aerosol in the central TP. Positive matrix factorization of the high-resolution mass spectra of OA identified two oxygenated

  17. Detection of methyl-, dimethyl- and diethylamine using a nitrate-based chemical ionization mass spectrometer

    Science.gov (United States)

    Jokinen, T.; Smith, J. N.

    2016-12-01

    New particle formation is one of the main sources of cloud condensation nuclei (CCN) contributing approximately half of the global CCN budget. The initial steps of nucleation have been studied for decades and it is widely accepted that in most places nucleation requires presence of sulphuric acid (SA) and cluster-stabilizing vapours. Recent results from the CLOUD chamber show that only a few pptv levels of dimethylamine (DMA) with SA forms stable clusters at boundary layer conditions. Ambient sulphuric acid is typically measured using nitrate-based chemical ionization mass spectrometers. Unfortunately, because of higher volatilities and stickiness of amines to surfaces, amine measurement techniques suffer from memory effects and high detection limits. Recently it was discovered that DMA can be detected by utilizing nitrate ionization, simultaneously with sulphuric acid measurements. Here we present results of detecting methylamine, dimethylamine and diethylamine using nitrate-based chemical ionization. We conducted a series of measurements with a home-built transverse chemical ionization inlet and a high resolution time-of-flight mass spectrometer (CI-HToF). Amine vapour was produced using permeation tubes. Three stages of dilution were applied at roughly one order-of-magnitude dilution per stage. The diluted flow of selected amine was then introduced to a sample flow rate of 7 slpm, thus achieving a final amine concentration of 10 pptv. All selected amines were detected as clusters with HNO3NO3- and showed linear response with increasing concentrations (0.5-minute integration time). Zero measurements were performed using clean nitrogen gas right after injection of a selected amine. Memory effects were only observed when using high amine concentrations (ppbv levels). Our results indicate that a variety of amines can be detected using nitrate-based chemical ionization mass spectrometers. However, more experiments are required to see if this presented method will be

  18. Mass spectral chemical fingerprints reveal the molecular dependence of exhaust particulate matters on engine speeds.

    Science.gov (United States)

    Li, Yi; Zhang, Hua; Zhao, Zongshan; Tian, Yong; Liu, Kun; Jie, Feifan; Zhu, Liang; Chen, Huanwen

    2018-05-01

    Particulate matters (PMs) emitted by automobile exhaust contribute to a significant fraction of the global PMs. Extractive atmospheric pressure chemical ionization mass spectrometry (EAPCI-MS) was developed to explore the molecular dependence of PMs collected from exhaust gases produced at different vehicle engine speeds. The mass spectral fingerprints of the organic compounds embedded in differentially sized PMs (e.g., 0.22-0.45, 0.45-1.00, 1.00-2.00, 2.00-3.00, 3.00-5.00, and 5.00-10.00μm) generated at different engine speeds (e.g., 1000, 1500, 2000, 2500, and 3000r/min) were chemically profiled in the mass range of mass to charge ratio (m/z) 50-800. Organic compounds, including alcohols, aldehydes, and esters, were detected in all the PMs tested, with varied concentration levels for each individual PM sample. At relatively low engine speeds (≤1500r/min), the total amount of organic species embedded in PMs of 0.22-1.00μm was greater than in PMs of other sizes, while more organic species were found in PMs of 5.00-10.00μm at high engine speeds (≥3000r/min), indicating that the organic compounds distributed in different sizes of PMs strongly correlated with the engine speed. The experimental data showed that the EAPCI-MS technique enables molecular characterization of PMs in exhaust, revealing the chemical dependence of PMs on the engine speeds (i.e., the combustion conditions) of automobiles. Copyright © 2017. Published by Elsevier B.V.

  19. Dissociation mechanism of HNIW ions investigated by chemical ionization and electron impact mass spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Rongjie; Xiao, Hemiao [School of Materials Science and Engineering, Beijing Institute of Technology, Beijing 100081 (China)

    2006-04-15

    Chemical Ionization (CI) with Collision-Induced Dissociation (CID) spectroscopy and Electron Impacting (EI) with metastable Mass analyzed Ion Kinetic Energy (MIKE) spectroscopy have been applied to study ionic dissociations of Hexanitrohexaazaisowurtzitane (HNIW). Similarities and differences between EI/MIKE and CI/CID mass spectra of HNIW were analyzed. In EI mass spectra, the ions [HNIW-n NO{sub 2}]{sup +} (n=2-5), such as the ion at m/z 347, were less frequent (1-2% relative abundance), but in CI mass spectra, these ions were very abundant. For some ions of large molar mass from HNIW, their dissociations pathways from parent ions to daughter ions were built according to CID and MIKE spectra. Molecular ions of HNIW with a protonated nitro group at five-member ring seem more stable than at six-member ring. The HNIW ions losing five of six nitro groups are very stable based on CID spectra, which agrees with some research results for thermal decomposition of HNIW in literature. (Abstract Copyright [2006], Wiley Periodicals, Inc.)

  20. Chemical characterization of microparticles by laser ablation in an ion trap mass spectrometer

    International Nuclear Information System (INIS)

    Dale, J.M.; Whitten, W.B.; Ramsey, J.M.

    1991-01-01

    We are developing a new technique for the chemical characterization of microparticles based upon the use of electrodynamic traps. The electrodynamic trap has achieved widespread use in the mass spectrometry community in the form of the ion trap mass spectrometer or quadrupole ion trap. Small macroscopic particles can be confined or levitated within the electrode structure of a three-dimensional quadrupole electrodynamic trap in the same way as fundamental charges or molecular ions by using a combination of ac and dc potentials. Our concept is to use the same electrode structure to perform both microparticle levitation and ion trapping/mass analysis. The microparticle will first be trapped and spatially stabilized within the trap for characterization by optical probes, i.e., absorption, fluorescence, or Raman spectroscopy. After the particle has been optically characterized, it is further characterized using mass spectrometry. Ions are generated from the particle surface using laser ablation or desorption. The characteristics of the applied voltages are changed to trap the ions formed by the laser with the ions subsequently mass analyzed. The work described in this paper focuses on the ability to perform laser desorption experiments on microparticles contained within the ion trap

  1. Thermoluminescent properties of CVD diamond: applications to ionising radiation dosimetry

    International Nuclear Information System (INIS)

    Petitfils, A.

    2007-09-01

    Remarkable properties of synthetic diamond (human soft tissue equivalence, chemical stability, non-toxicity) make this material suitable for medical application as thermoluminescent dosimeter (TLD). This work highlights the interest of this material as radiotherapy TLD. In the first stage of this work, we looked after thermoluminescent (TL) and dosimetric properties of polycrystalline diamond made by Chemically Vapor Deposited (CVD) synthesis. Dosimetric characteristics are satisfactory as TLD for medical application. Luminescence thermal quenching on diamond has been investigated. This phenomenon leads to a decrease of dosimetric TL peak sensitivity when the heating rate increases. The second part of this work analyses the use of synthetic diamond as TLD in radiotherapy. Dose profiles, depth dose distributions and the cartography of an electron beam obtained with our samples are in very good agreement with results from an ionisation chamber. It is clearly shown that CVD) diamond is of interest to check beams of treatment accelerators. The use of these samples in a control of treatment with Intensity Modulated Radiation Therapy underlines good response of synthetic diamond in high dose gradient areas. These results indicate that CVD diamond is a promising material for radiotherapy dosimetry. (author)

  2. Influence of mass transfer and chemical reaction on ozonation of azo dyes

    Energy Technology Data Exchange (ETDEWEB)

    Choi, I.S.; Wiesmann, U. [Dept. of Environmental Engineering, Technical Univ. of Berlin, Berlin (Germany)

    2003-07-01

    Azo dyes can be only mineralised by chemical oxidation. In this paper the oxidation of reactive black 5 (RB 5) and reactive orange 96 (RO 96) with concentrations between 35 and 5700 mgL{sup -1} (RB 5) and between 20 and 2050 mgL{sup -1} (RO 96) is investigated. A lab scale bubble column was used, which was gassed by a mixture of O{sub 2} and O{sub 3}. The oxidation rate was influenced by mass transfer for all dye concentrations used. For lower dye concentrations mass transfer alone was decisive for reaction rate showing an enhancement factor of E {approx} 1. However, in the region of higher dye concentrations, the slope of the decreasing ozone concentration inside the liquid boundary layer increases more and more with increasing dye concentration as a result of a chemical oxidation. Therefore, the enhancement factor depends on the kind and concentration of the azo dyes. For RB 5 as an diazo dye an enhancement factor of E = 9 was observed for 3800 mgL{sup -1}, RO 96 as a mono azo dye with a remarkable higher chemical oxidation rate shows an E = 17 already for 2050 mgL{sup -1}. (orig.)

  3. Chemical characterization of synthetic cannabinoids by electrospray ionization FT-ICR mass spectrometry.

    Science.gov (United States)

    Kill, Jade B; Oliveira, Izabela F; Tose, Lilian V; Costa, Helber B; Kuster, Ricardo M; Machado, Leandro F; Correia, Radigya M; Rodrigues, Rayza R T; Vasconcellos, Géssica A; Vaz, Boniek G; Romão, Wanderson

    2016-09-01

    The synthetic cannabinoids (SCs) represent the most recent advent of the new psychotropic substances (NPS) and has become popularly known to mitigate the effects of the Δ(9)-THC. The SCs are dissolved in organic solvents and sprayed in a dry herbal blend. However, little information is reported on active ingredients of SCs as well as the excipients or diluents added to the herbal blend. In this work, the direct infusion electrospray ionization Fourier transform ion cyclotron mass spectrometry technique (ESI-FT-ICR MS) was applied to explore the chemical composition of nine samples of herbal extract blends, where a total of 11 SCs (UR-144, JWH-073, XLR-11, JWH-250, JWH-122, AM-2201, AKB48, JWH-210, JWH-081, MAM-2201 and 5F-AKB48) were identified in the positive ionization mode, ESI(+), and other 44 chemical species (saturated and unsaturated fatty acids, sugars, flavonoids, etc.) were detected in the negative ionization mode, ESI(-). Additionally, CID experiments were performed, and fragmentation pathways were proposed to identify the connectivity of SCs. Thus, the direct infusion ESI-FT-ICR MS technique is a powerful tool in forensic chemistry that enables the rapid and unequivocal way for the determination of molecular formula, the degree of unsaturation (DBE-double bond equivalent) and exact mass (<1ppm) of a total of 55 chemical species without the prior separation step. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Humidity independent mass spectrometry for gas phase chemical analysis via ambient proton transfer reaction.

    Science.gov (United States)

    Zhu, Hongying; Huang, Guangming

    2015-03-31

    In this work, a humidity independent mass spectrometric method was developed for rapid analysis of gas phase chemicals. This method is based upon ambient proton transfer reaction between gas phase chemicals and charged water droplets, in a reaction chamber with nearly saturate humidity under atmospheric pressure. The humidity independent nature enables direct and rapid analysis of raw gas phase samples, avoiding time- and sample-consuming sample pretreatments in conventional mass spectrometry methods to control sample humidity. Acetone, benzene, toluene, ethylbenzene and meta-xylene were used to evaluate the analytical performance of present method. The limits of detection for benzene, toluene, ethylbenzene and meta-xylene are in the range of ∼0.1 to ∼0.3 ppbV; that of benzene is well below the present European Union permissible exposure limit for benzene vapor (5 μg m(-3), ∼1.44 ppbV), with linear ranges of approximately two orders of magnitude. The majority of the homemade device contains a stainless steel tube as reaction chamber and an ultrasonic humidifier as the source of charged water droplets, which makes this cheap device easy to assemble and facile to operate. In addition, potential application of this method was illustrated by the real time identification of raw gas phase chemicals released from plants at different physiological stages. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Effect of dimethylamine on the gas phase sulfuric acid concentration measured by Chemical Ionization Mass Spectrometry

    CERN Document Server

    Rondo, L.; Kürten, A.; Adamov, A.; Bianchi, F.; Breitenlechner, M.; Duplissy, J.; Franchin, A.; Dommen, J.; Donahue, N. M.; Dunne, E. M.; Flagan, R. C.; Hakala, J.; Hansel, A.; Keskinen, H.; Kim, J.; Jokinen, T.; Lehtipalo, K.; Leiminger, M.; Praplan, A.; Riccobono, F.; Rissanen, M. P.; Sarnela, N.; Schobesberger, S.; Simon, M.; Sipilä, M.; Smith, J. N.; Tomé, A.; Tröstl, J.; Tsagkogeorgas, G.; Vaattovaara, P.; Winkler, P. M.; Williamson, C.; Wimmer, D.; Baltensperger, U.; Kirkby, J.; Kulmala, M.; Petäjä, T.; Worsnop, D. R.; Curtius, J.

    2016-01-01

    Sulfuric acid is widely recognized as a very important substance driving atmospheric aerosolnucleation. Based on quantum chemical calculations it has been suggested that the quantitative detectionof gas phase sulfuric acid (H2SO4) by use of Chemical Ionization Mass Spectrometry (CIMS) could be biased inthe presence of gas phase amines such as dimethylamine (DMA). An experiment (CLOUD7 campaign) was setup at the CLOUD (Cosmics Leaving OUtdoor Droplets) chamber to investigate the quantitative detection ofH2SO4in the presence of dimethylamine by CIMS at atmospherically relevant concentrations. For the first time inthe CLOUD experiment, the monomer sulfuric acid concentration was measured by a CIMS and by two CI-APi-TOF(Chemical Ionization-Atmospheric Pressure interface-Time Of Flight) mass spectrometers. In addition, neutralsulfuric acid clusters were measured with the CI-APi-TOFs. The CLOUD7 measurements show that in the presenceof dimethylamine (<5 to 70 pptv) the sulfuric acid monomer measured by the CIMS...

  6. Application of molecular beam mass spectrometry to chemical vapor deposition studies

    International Nuclear Information System (INIS)

    Hsu, W.L.; Tung, D.M.

    1992-01-01

    A molecular beam mass spectrometer system has been designed and constructed for the specific purpose of measuring the gaseous composition of the vapor environment during chemical vapor deposition of diamond. By the intrinsic nature of mass analysis, this type of design is adaptable to a broad range of other applications that rely either on thermal- or plasma-induced chemical kinetics. When gas is sampled at a relatively high process pressure (∼2700 Pa for our case), supersonic gas expansion at the sampling orifice can cause the detected signals to have a complicated dependence on the operating conditions. A comprehensive discussion is given on the effect of gas expansion on mass discrimination and signal scaling with sampling pressure and temperature, and how these obstacles can be overcome. This paper demonstrates that radical species can be detected with a sensitivity better than 10 ppm by the use of threshold ionization. A detailed procedure is described whereby one can achieve quantitative analysis of the detected species with an accuracy of ±20%. This paper ends with an example on the detection of H, H 2 , CH 3 , CH 4 , and C 2 H 2 during diamond growth

  7. Resonance Ionization Mass Spectrometry (RIMS): applications in spectroscopy and chemical dynamics

    International Nuclear Information System (INIS)

    Naik, P.D.; Kumar, Awadhesh; Upadhyaya, Hari; Bajaj, P.N.

    2009-01-01

    Resonance ionization is a photophysical process wherein electromagnetic radiation is used to ionize atoms, molecules, transient species, etc., by exciting them through their quantum states. The number of photons required to ionize depends on the species being investigated and energy of the photon. Once a charged particle is produced, it is easy to detect it with high efficiency. With the advent of narrow band high power pulsed and cw tunable dye lasers, it has blossomed into a powerful spectroscopic and analytical technique, commonly known as resonance ionization spectroscopy (RIS)/resonance enhanced multiphoton ionization (REMPI). The alliance of resonance ionization with mass spectrometry has grown into a still more powerful technique, known as resonance ionization mass spectrometry (RIMS), which has made significant contributions in a variety of frontier areas of research and development, such as spectroscopy, chemical dynamics, analytical chemistry, cluster science, surface science, radiochemistry, nuclear physics, biology, environmental science, material science, etc. In this article, we shall describe the application of resonance ionization mass spectrometry to spectroscopy of uranium and chemical dynamics of polyatomic molecules

  8. Extractive Atmospheric Pressure Photoionization (EAPPI) Mass Spectrometry: Rapid Analysis of Chemicals in Complex Matrices.

    Science.gov (United States)

    Liu, Chengyuan; Yang, Jiuzhong; Wang, Jian; Hu, Yonghua; Zhao, Wan; Zhou, Zhongyue; Qi, Fei; Pan, Yang

    2016-10-01

    Extractive atmospheric pressure photoionization (EAPPI) mass spectrometry was designed for rapid qualitative and quantitative analysis of chemicals in complex matrices. In this method, an ultrasonic nebulization system was applied to sample extraction, nebulization, and vaporization. Mixed with a gaseous dopant, vaporized analytes were ionized through ambient photon-induced ion-molecule reactions, and were mass-analyzed by a high resolution time-of-flight mass spectrometer (TOF-MS). After careful optimization and testing with pure sample solution, EAPPI was successfully applied to the fast screening of capsules, soil, natural products, and viscous compounds. Analysis was completed within a few seconds without the need for preseparation. Moreover, the quantification capability of EAPPI for matrices was evaluated by analyzing six polycyclic aromatic hydrocarbons (PAHs) in soil. The correlation coefficients (R (2) ) for standard curves of all six PAHs were above 0.99, and the detection limits were in the range of 0.16-0.34 ng/mg. In addition, EAPPI could also be used to monitor organic chemical reactions in real time. Graphical Abstract ᅟ.

  9. Mass Spectrometry of Intact Proteins Reveals +98 u Chemical Artifacts Following Precipitation in Acetone.

    Science.gov (United States)

    Güray, Melda Z; Zheng, Shi; Doucette, Alan A

    2017-02-03

    Protein precipitation in acetone is frequently employed ahead of mass spectrometry for sample preconcentration and purification. Unfortunately, acetone is not chemically inert; mass artifacts have previously been observed on glycine-containing peptides when exposed to acetone under acidic conditions. We herein report a distinct chemical modification occurring at the level of intact proteins when incubated in acetone. This artifact manifests as one or more satellite peaks in the MS spectrum of intact protein, spaced 98 u above the mass of the unmodified protein. Other artifacts (+84, +112 u) also appear upon incubation of proteins or peptides in acetone. The reaction is pH-sensitive, being suppressed when proteins are exposed to acetone under acidic conditions. The +98 u artifact is speculated to originate through an intermediate product of aldol condensation of acetone to form diacetone alcohol and mesityl oxide. A +98 u product could originate from nucleophilic attack on mesityl oxide or through condensation with diacetone alcohol. Given the extent of modification possible upon exposure of proteins to acetone, particularly following overnight solvent exposure or incubation at room temperature, an awareness of the variables influencing this novel modification is valued by proteomics researchers who employ acetone precipitation for protein purification.

  10. Ion source for a mass spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Kappus, G.

    1980-07-24

    The ion source is used for electron impact ionisation and chemical ionisation of a gaseous or vapour test substance. In this type of operation, openings of different sizes are provided for the entry of electrons, the exit of ions and sample entry, because of different working pressures.

  11. Immunosuppression by non-ionising and ionising radiation - are there similarities?

    International Nuclear Information System (INIS)

    Reeves, V.

    2003-01-01

    Solar UV radiation, the ubiqitous environmental non-ionising radiation, initiates its immunomodulating effects almost entirely in the skin. In direct contrast, ionising radiation penetrates much more efficiently, and has a multitude of internal targets throughout the body. As a consequence, the mechanisms underlying UV-induced immunosuppression have been more readily characterised, whereas surprisingly little is known about immunosuppression resulting from ionising radiation. Photoimmunological studies in mice during the past 20-30 years have established the action spectrum for UV-induced immunosuppression, implicating the UVB waveband, 290-320 nm. Controversy rages over the immunosuppressive potential of the UVA waveband, 320-400 nm, but we demonstrate that environmentally relevant doses of UVA not only are immunologically innocuous, but provide protection against UVB-immunosuppression. Increasingly larger UVA exposures increasingly immunosuppress mice. The UVA immunoprotective effect is strongly dependent on the induction of a cutaneous redox-regulated enzyme, haem oxygenase (heat shock protein 32) that is known to protect cells from oxidative stress, and it is consistent that a number of exogenous antioxidants (vitamin E, vitamin C, green tea polyphenols, isoflavones) can protect effectively from photoimmuno-suppression. Thus the UV-immunosuppressed state is promoted by oxidative damage and depletion of endogenous antioxidant molecules. It is also associated with cutaneous cytokine derangements, such that Th-2 cytokines (IL-4, IL-10) are increased at the expense of Th-1 cytokines (IFN-gamma, IL-12), and with histamine and inflammatory prostaglandin activity. In contrast, immunoprotective UVA irradiation protects the cutaneous cytokine array, inhibits IL-10 upregulation and increases IFN-gamma and IL-12 expression. On the other hand, while ionising radiation is known to cause immunosuppression, large doses target the bone marrow and haemopoiesis lethally and

  12. Dedicated Trigger for Highly Ionising Particles at ATLAS

    CERN Document Server

    Katre, Akshay; The ATLAS collaboration

    2015-01-01

    In 2012, a novel strategy was designed to detect signatures of Highly Ionising Particles (HIPs) such as magnetic monopoles, dyons or Qballs with the ATLAS trigger system. With proton-proton collisions at a centre of mass enegy of 8 TeV, the trigger was designed to have unique properties as a tracker for HIPs. It uses only the Transition Radiation Tracker (TRT) system, applying an algorithm distinct from standard tracking ones. The unique high threshold readout capability of the TRT is used at the location where HIPs in the detector are looked for. In particular the number and the fraction of TRT high threshold hits is used to distinguish HIPs from background processes. The trigger requires significantly lower energy depositions in the electro-magnetic calorimeters as a seed unlike previously used trigger algorithms for such searches. Thus the new trigger is capable of probing a large range of HIP masses and charges. We will give a description of the algorithms for this newly developed trigger for HIP searches...

  13. Full Ionisation In Binary-Binary Encounters With Small Positive Energies

    Science.gov (United States)

    Sweatman, W. L.

    2006-08-01

    Interactions between binary stars and single stars and binary stars and other binary stars play a key role in the dynamics of a dense stellar system. Energy can be transferred between the internal dynamics of a binary and the larger scale dynamics of the interacting objects. Binaries can be destroyed and created by the interaction. In a binary-binary encounter, full ionisation occurs when both of the binary stars are destroyed in the interaction to create four single stars. This is only possible when the total energy of the system is positive. For very small energies the probability of this occurring is very low and it tends towards zero as the total energy tends towards zero. Here the case is considered for which all the stars have equal masses. An asymptotic power law is predicted relating the probability of full ionisation with the total energy when this latter quantity is small. The exponent, which is approximately 2.31, is compared with the results from numerical scattering experiments. The theoretical approach taken is similar to one used previously in the three-body problem. It makes use of the fact that the most dramatic changes in scale and energies of a few-body system occur when its components pass near to a central configuration. The position, and number, of these configurations is not known for the general four-body problem, however, with equal masses there are known to be exactly five different cases. Separate consideration and comparison of the properties of orbits close to each of these five central configurations enables the prediction of the form of the cross-section for full ionisation for the case of small positive total energy. This is the relation between total energy and the probability of total ionisation described above.

  14. Ultrasonic nebulization extraction/low pressure photoionization mass spectrometry for direct analysis of chemicals in matrices.

    Science.gov (United States)

    Liu, Chengyuan; Zhu, Yanan; Zhou, Zhongyue; Yang, Jiuzhong; Qi, Fei; Pan, Yang

    2015-09-03

    A novel ultrasonic nebulization extraction/low-pressure photoionization (UNE-LPPI) system has been designed and employed for the rapid mass spectrometric analysis of chemicals in matrices. An ultrasonic nebulizer was used to extract the chemicals in solid sample and nebulize the solvent in the nebulization cell. Aerosols formed by ultrasonic were evaporated by passing through a transferring tube, and desolvated chemicals were ionized by the emitted light (10.6 eV) from a Krypton discharge lamp at low pressure (∼68 Pa). First, a series of semi/non-volatile compounds with different polarities, such as polycyclic aromatic hydrocarbons (PAHs), amino acids, dipeptides, drugs, nucleic acids, alkaloids, and steroids were used to test the system. Then, the quantification capability of UNE-LPPI was checked with: 1) pure chemicals, such as 9,10-phenanthrenequinone and 1,4-naphthoquinone dissolved in solvent; 2) soil powder spiked with different amounts of phenanthrene and pyrene. For pure chemicals, the correlation coefficient (R(2)) for the standard curve of 9,10-phenanthrenequinone in the range of 3 ng-20 μg mL(-1) was 0.9922, and the measured limits of detection (LOD) was 1 ng ml(-1). In the case of soil powder, linear relationships for phenanthrene and pyrene from 10 to 400 ng mg(-1) were obtained with correlation coefficients of 0.9889 and 0.9893, respectively. At last, the feasibility of UNE-LPPI for the detection of chemicals in real matrices such as tablets and biological tissues (tea, Citrus aurantium peel and sage (Salvia officinalis) leaf) were successfully demonstrated. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. The XUV spectra of highly ionised molybdenum

    International Nuclear Information System (INIS)

    Mansfield, M.W.D.; Peacock, N.J.; Smith, C.C.; Hobby, M.G.; Cowan, R.D.

    1978-01-01

    The spectra of molybdenum ions produced in Tokamaks in the wavelength range 10-200 A have been reproduced in a plasma formed by laser beam irradiation of solid molybdenum targets. Lines from highly ionised stages of molybdenum (Mo XXX to Mo XXXII) have been distinguished by varying the laser beam intensity. Detailed analyses of the simpler ions, Mo XV (Ni-like), Mo XVI (Co-like), Mo XXXII (Na-like), and to a lesser extent Mo XXXI (Mg-like) and Mo XVII (Fe-like), have been achieved by comparison with ab initio calculations. A general interpretation of intermediate ion stages is also given but it is shown that most of these spectra are so complex, as a result of inner-subshell excitation, that detailed term-scheme analyses are nearly impossible. (author)

  16. XUV spectra of highly ionised molybdenum

    Energy Technology Data Exchange (ETDEWEB)

    Mansfield, M W.D.; Peacock, N J; Smith, C C; Hobby, M G [UKAEA, Abingdon. Culham Lab.; Cowan, R D

    1978-05-14

    The spectra of molybdenum ions produced in Tokamaks in the wavelength range 10-200 A have been reproduced in a plasma formed by laser beam irradiation of solid molybdenum targets. Lines from highly ionised stages of molybdenum (Mo XXX to Mo XXXII) have been distinguished by varying the laser beam intensity. Detailed analyses of the simpler ions, Mo XV (Ni-like), Mo XVI (Co-like), Mo XXXII (Na-like), and to a lesser extent Mo XXXI (Mg-like) and Mo XVII (Fe-like), have been achieved by comparison with ab initio calculations. A general interpretation of intermediate ion stages is also given but it is shown that most of these spectra are so complex, as a result of inner-subshell excitation, that detailed term-scheme analyses are nearly impossible.

  17. Mass spectrographic analysis of selected chemical elements by microbial leaching of zircon

    International Nuclear Information System (INIS)

    Becker, S.; Dietze, H.J.; Bullmann, M.; Iske, U.

    1986-01-01

    Spark source mass spectrometry is a useful method for chemical element analysis of geological and biological samples. This sensitive technique (detection limit down to the ppb-range) is used to analyze leaching processes by means of several microorganisms. The problem of microbial leaching of chemical resistent materials was tested under laboratory conditions with regard to possible analytical and technical applications. Leaching of metals with chemolithotrophic and heterotrophic, organic acids producing microorganisms has been investigated with zircon from the Baltic Shield containing 0.7% rare earth elements and 1.67% hafnium. When zircon is leached with strains of thiobacillus ferrooxidans about 80% of the rare earth elements, Hf, Th and U can be recovered. (orig.) [de

  18. Quantitative analysis of abused drugs in physiological fluids by gas chromatography/chemical ionization mass spectrometry

    International Nuclear Information System (INIS)

    Foltz, R.L.

    1978-01-01

    Methods have been developed for quantitative analysis of commonly abused drugs in physiological fluids using gas chromatography/chemical ionization mass spectrometry. The methods are being evaluated in volunteer analytical and toxicological laboratories, and analytical manuals describing the methods are being prepared. The specific drug and metabolites included in this program are: Δ 9 -tetrahydrocannabinol, methadone, phencyclidine, methaqualone, morphine, amphetamine, methamphetamine, mescaline, 2,5-dimethoxy-4-methyl amphetamine, cocaine, benzoylecgonine, diazepam, and N-desmethyldiazepam. The current analytical methods utilize relatively conventional instrumentation and procedures, and are capable of measuring drug concentrations as low as 1 ng/ml. Various newer techniques such as sample clean-up by high performance liquid chromatography, separation by glass capillary chromatography, and ionization by negative ion chemical ionization are being investigated with respect to their potential for achieving higher sensitivity and specificity, as well as their ability to facilitate simultaneous analysis of more than one drug and metabolite. (Auth.)

  19. Modelling of Mass Transfer Phenomena in Chemical and Biochemical Reactor Systems using Computational Fluid Dynamics

    DEFF Research Database (Denmark)

    Larsson, Hilde Kristina

    the velocity and pressure distributions in a fluid. CFD also enables the modelling of several fluids simultaneously, e.g. gas bubbles in a liquid, as well as the presence of turbulence and dissolved chemicals in a fluid, and many other phenomena. This makes CFD an appreciated tool for studying flow structures......, mixing, and other mass transfer phenomena in chemical and biochemical reactor systems. In this project, four selected case studies are investigated in order to explore the capabilities of CFD. The selected cases are a 1 ml stirred microbioreactor, an 8 ml magnetically stirred reactor, a Rushton impeller...... and an ion-exchange reaction are also modelled and compared to experimental data. The thesis includes a comprehensive overview of the fundamentals behind a CFD software, as well as a more detailed review of the fluid dynamic phenomena investigated in this project. The momentum and continuity equations...

  20. The chemical evolution of a travertine-depositing stream: Geochemical processes and mass transfer reactions

    Science.gov (United States)

    Lorah, Michelle M.; Herman, Janet S.

    1988-01-01

    This field study focuses on quantitatively defining the chemical changes occurring in Falling Spring Creek, a travertine-depositing stream located in Alleghany County, Virginia. The processes of CO2outgassing and calcite precipitation or dissolution control the chemical evolution of the stream. The observed chemical composition of the water was used with the computerized geochemical model WATEQF to calculate aqueous speciation, saturation indices, and CO2 partial pressure values. Mass balance calculations were performed to obtain mass transfers of CO2 and calcite. Reaction times, estimated from stream discharge, were used with the mass transfer results to calculate rates of CO2, outgassing and calcite precipitation between consecutive sampling points. The stream, which is fed by a carbonate spring, is supersaturated with respect to CO2 along the entire 5.2-km flow path. Outgassing of CO2 drives the solution to high degrees of supersaturation with respect to calcite. Metabolic uptake of CO2 by photosynthetic plants is insignificant, because the high supply rate of dissolved carbon dioxide and the extreme agitation of the stream at waterfalls and rapids causes a much greater amount of inorganic CO2 outgassing to occur. Calcite precipitation is kinetically inhibited until near the crest of a 20-m vertical waterfall. Calcite precipitation rates then reach a maximum at the waterfall where greater water turbulence allows the most rapid escape of CO2. Physical evidence for calcite precipitation exists in the travertine deposits which are first observed immediately above the waterfall and extend for at least 1.0 km below the falls. Net calcite precipitation occurs at all times of the year but is greatest during low-flow conditions in the summer and early fall.

  1. Top Down Tandem Mass Spectrometric Analysis of a Chemically Modified Rough-Type Lipopolysaccharide Vaccine Candidate

    Science.gov (United States)

    Oyler, Benjamin L.; Khan, Mohd M.; Smith, Donald F.; Harberts, Erin M.; Kilgour, David P. A.; Ernst, Robert K.; Cross, Alan S.; Goodlett, David R.

    2018-02-01

    Recent advances in lipopolysaccharide (LPS) biology have led to its use in drug discovery pipelines, including vaccine and vaccine adjuvant discovery. Desirable characteristics for LPS vaccine candidates include both the ability to produce a specific antibody titer in patients and a minimal host inflammatory response directed by the innate immune system. However, in-depth chemical characterization of most LPS extracts has not been performed; hence, biological activities of these extracts are unpredictable. Additionally, the most widely adopted workflow for LPS structure elucidation includes nonspecific chemical decomposition steps before analyses, making structures inferred and not necessarily biologically relevant. In this work, several different mass spectrometry workflows that have not been previously explored were employed to show proof-of-principle for top down LPS primary structure elucidation, specifically for a rough-type mutant (J5) E. coli-derived LPS component of a vaccine candidate. First, ion mobility filtered precursor ions were subjected to collision induced dissociation (CID) to define differences in native J5 LPS v. chemically detoxified J5 LPS (dLPS). Next, ultra-high mass resolving power, accurate mass spectrometry was employed for unequivocal precursor and product ion empirical formulae generation. Finally, MS3 analyses in an ion trap instrument showed that previous knowledge about dissociation of LPS components can be used to reconstruct and sequence LPS in a top down fashion. A structural rationale is also explained for differential inflammatory dose-response curves, in vitro, when HEK-Blue hTLR4 cells were administered increasing concentrations of native J5 LPS v. dLPS, which will be useful in future drug discovery efforts. [Figure not available: see fulltext.

  2. Weapons of mass destruction: Overview of the CBRNEs (Chemical, Biological, Radiological, Nuclear, and Explosives).

    Science.gov (United States)

    Prockop, Leon D

    2006-11-01

    The events of September 11, 2001, made citizens of the world acutely aware of disasters consequent to present-day terrorism. This is a war being waged for reasons obscure to many of its potential victims. The term "NBCs" was coined in reference to terrorist weapons of mass destruction, i.e., nuclear, biological and chemical. The currently accepted acronym is "CBRNE" which includes Chemical, Biological, Radiological, Nuclear, and Explosive weapons. Non-nuclear explosives are the most common terrorist weapon now in use. Nuclear and radiological weapons are beyond the scope of this publication, which focuses on the "CBEs", i.e. chemical, biological and explosive weapons. Although neurologists will not be the first responders to CBEs, they must know about the neurological effects in order to provide diagnosis and treatment to survivors. Neurological complications of chemical, biological and explosive weapons which have or may be used by terrorists are reviewed by international experts in this publication. Management and treatment profiles are outlined.

  3. Empirical Correction for Differences in Chemical Exchange Rates in Hydrogen Exchange-Mass Spectrometry Measurements.

    Science.gov (United States)

    Toth, Ronald T; Mills, Brittney J; Joshi, Sangeeta B; Esfandiary, Reza; Bishop, Steven M; Middaugh, C Russell; Volkin, David B; Weis, David D

    2017-09-05

    A barrier to the use of hydrogen exchange-mass spectrometry (HX-MS) in many contexts, especially analytical characterization of various protein therapeutic candidates, is that differences in temperature, pH, ionic strength, buffering agent, or other additives can alter chemical exchange rates, making HX data gathered under differing solution conditions difficult to compare. Here, we present data demonstrating that HX chemical exchange rates can be substantially altered not only by the well-established variables of temperature and pH but also by additives including arginine, guanidine, methionine, and thiocyanate. To compensate for these additive effects, we have developed an empirical method to correct the hydrogen-exchange data for these differences. First, differences in chemical exchange rates are measured by use of an unstructured reporter peptide, YPI. An empirical chemical exchange correction factor, determined by use of the HX data from the reporter peptide, is then applied to the HX measurements obtained from a protein of interest under different solution conditions. We demonstrate that the correction is experimentally sound through simulation and in a proof-of-concept experiment using unstructured peptides under slow-exchange conditions (pD 4.5 at ambient temperature). To illustrate its utility, we applied the correction to HX-MS excipient screening data collected for a pharmaceutically relevant IgG4 mAb being characterized to determine the effects of different formulations on backbone dynamics.

  4. Effects of temperature and mass conservation on the typical chemical sequences of hydrogen oxidation

    Science.gov (United States)

    Nicholson, Schuyler B.; Alaghemandi, Mohammad; Green, Jason R.

    2018-01-01

    Macroscopic properties of reacting mixtures are necessary to design synthetic strategies, determine yield, and improve the energy and atom efficiency of many chemical processes. The set of time-ordered sequences of chemical species are one representation of the evolution from reactants to products. However, only a fraction of the possible sequences is typical, having the majority of the joint probability and characterizing the succession of chemical nonequilibrium states. Here, we extend a variational measure of typicality and apply it to atomistic simulations of a model for hydrogen oxidation over a range of temperatures. We demonstrate an information-theoretic methodology to identify typical sequences under the constraints of mass conservation. Including these constraints leads to an improved ability to learn the chemical sequence mechanism from experimentally accessible data. From these typical sequences, we show that two quantities defining the variational typical set of sequences—the joint entropy rate and the topological entropy rate—increase linearly with temperature. These results suggest that, away from explosion limits, data over a narrow range of thermodynamic parameters could be sufficient to extrapolate these typical features of combustion chemistry to other conditions.

  5. Methods of direct (non-chromatographic) quantification of body metabolites utilizing chemical ionization mass spectrometry

    International Nuclear Information System (INIS)

    Mee, J.M.L.

    1978-01-01

    For quantitative determination of known metabolites from the biological sample by direct chemical ionization mass spectrometry (CI-MS), the method of internal standard using stable isotopically labelled analogs appears to be the method of choice. In the case where stable isotope ratio determinations could not be applied, and alternative quantification can be achieved using non-labelled external or internal standards and a calibration curve (sum of peak height per a given number of scans versus concentration). The technique of computer monitoring permits display and plotting of ion current profiles (TIC and SIC) or spectra per a given number of scans or a given range of mass per charge. Examples are given in areas of clinical application and the quantitative data show very good agreement with the conventional chromatographic measurements. (Auth.)

  6. Standard test methods for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of uranium hexafluoride

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover procedures for subsampling and for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of uranium hexafluoride UF6. Most of these test methods are in routine use to determine conformance to UF6 specifications in the Enrichment and Conversion Facilities. 1.2 The analytical procedures in this document appear in the following order: Note 1—Subcommittee C26.05 will confer with C26.02 concerning the renumbered section in Test Methods C761 to determine how concerns with renumbering these sections, as analytical methods are replaced with stand-alone analytical methods, are best addressed in subsequent publications. Sections Subsampling of Uranium Hexafluoride 7 - 10 Gravimetric Determination of Uranium 11 - 19 Titrimetric Determination of Uranium 20 Preparation of High-Purity U3O 8 21 Isotopic Analysis 22 Isotopic Analysis by Double-Standard Mass-Spectrometer Method 23 - 29 Determination of Hydrocarbons, Chlorocarbons, and Partially Substitut...

  7. Determination of clebopride in plasma by capillary gas chromatography-negative-ion chemical ionization mass spectrometry.

    Science.gov (United States)

    Robinson, P R; Jones, M D; Maddock, J

    1988-11-18

    A procedure for the analysis of clebopride in plasma using capillary gas chromatography-negative-ion chemical ionization mass spectrometry has been developed. Employing an ethoxy analogue as internal standard, the two compounds were extracted from basified plasma using dichloromethane. Subsequent reaction with heptafluorobutyryl imidazole produced volatile monoheptafluorobutyryl derivatives whose ammonia negative-ion mass spectra proved ideal for selected-ion monitoring. The recovery of clebopride from plasma at 0.536 nmol/l was found to be 85.5 +/- 0.9% (n = 3) whilst measurement down to 0.268 nmol/l was possible with a coefficient of variation of 7.9%. Plasma levels of the compound are reported in two volunteers following ingestion of 1 mg of clebopride as the malate salt.

  8. Standard test methods for chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade boron carbide

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 These test methods cover procedures for the chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade boron carbide powder and pellets to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Total Carbon by Combustion and Gravimetry 7-17 Total Boron by Titrimetry 18-28 Isotopic Composition by Mass Spectrometry 29-38 Chloride and Fluoride Separation by Pyrohydrolysis 39-45 Chloride by Constant-Current Coulometry 46-54 Fluoride by Ion-Selective Electrode 55-63 Water by Constant-Voltage Coulometry 64-72 Impurities by Spectrochemical Analysis 73-81 Soluble Boron by Titrimetry 82-95 Soluble Carbon by a Manometric Measurement 96-105 Metallic Impurities by a Direct Reader Spectrometric Method 106-114

  9. Effects of mass transfer on MHD flow of casson fluid with chemical reaction and suction

    Directory of Open Access Journals (Sweden)

    S. A. Shehzad

    2013-03-01

    Full Text Available Effect of mass transfer in the magnetohydrodynamic flow of a Casson fluid over a porous stretching sheet is addressed in the presence of a chemical reaction. A series solution for the resulting nonlinear flow is computed. The skin friction coefficient and local Sherwood number are analyzed through numerical values for various parameters of interest. The velocity and concentration fields are illustrated for several pertinent flow parameters. We observed that the Casson parameter and Hartman number have similar effects on the velocity in a qualitative sense. We further analyzed that the concentration profile decreases rapidly in comparison to the fluid velocity when we increased the values of the suction parameter.

  10. Chemical separation of plutonium from air filters and preparation of filaments for resonance ionization mass spectroscopy

    International Nuclear Information System (INIS)

    Eberhardt, K.; Erdmann, N.; Funk, H.; Herrmann, G.; Naehler, A.; Passler, G.; Trautmann, N.; Urban, F.

    1995-01-01

    Resonance ionization mass spectroscopy (RIMS) is used for the determination of plutonium in environmental samples. A chemical procedure based on an ion-exchange technique for the separation of plutonium from a polycarbonate filter is described. The overall yield is about 60% as determined by α-particle spectroscopy. A technique for the subsequent preparation of samples for RIMS measurements is developed. Plutonium is electrode-posited as hydroxide and covered with a thin metallic layer. While heating such a sandwich filament the plutonium hydroxide is reduced to the metal and an atomic beam is evaporated from the surface, as required for RIMS. copyright American Institute of Physics 1995

  11. Determination of sulfonamides in meat by liquid chromatography coupled with atmospheric pressure chemical ionization mass spectrometry

    International Nuclear Information System (INIS)

    Kim, Dal Ho; Choi, Jong Oh; Kim, Jin Seog; Lee, Dai Woon

    2002-01-01

    Liquid chromatography/atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS) has been used for the determination of sulfonamides in meat. Five typical sulfonamides were selected as target compounds, and beef meat was selected as a matrix sample. As internal standards, sulfapyridine and isotope labeled sulfamethazine ( 13 C 6 -SMZ) were used. Compared to the results of recent reports, our results have shown improved precision to a RSD of 1.8% for the determination of sulfamethazine spiked with 75 ng/g level in meat

  12. Chemical characterization using gas chromatography/mass spectrometry of two extracts from Phyllanthus orbicularis HBK

    International Nuclear Information System (INIS)

    Gutierrez Gaiten, Yamilet Irene; Miranda Martinez, Migdalia; Bello Alarcon, Adonis

    2011-01-01

    The objective of this paper was the chemical characterization of two extracts from Phyllanthus orbicularis HBK through gas chromatography/mass spectrometry. To this end, maceration with N-hexane and ethyl acetate was used to obtain the respective extracts. The study of the hexane extract identified 17 components in which hydrocarbonate structures prevailed, mainly cyclooctacosane. In the ethyl acetate extract, 19 compounds were detected, being the terpenoids the predominant, although the most abundant was sterol g-sitosterol. For the first time, the identified compounds are reported for this species

  13. Estimate the Chemical Formula of Organic Compounds from Mass Spectrometry Data

    International Nuclear Information System (INIS)

    Tigor Nauli

    2002-01-01

    Mass spectrometer is one of the analysis methods that can determine molecular weight of a substance precisely. Molecular ionic mass measured by the spectrometer represents sum of its isotopes weight with high abundance. It is not equal to the atomic weights from average total of natural isotope of elements. Therefore, a single mass measurement suffices to decide the formula of a substance. Formula determination using mass data by trial and error is a cumbersome work. An algorithm developed by Lederberg can be used to predict molecular formulas from an integer molecular weight. It will search for all linear combination of mass after the molecular weight divided by one of its isotopes weight. Selection of the right molecular formula from a list of possible formulas can be assisted by the relative abundance of its isotopes. The heavy isotopes will appear in the spectrum as small peaks at one or more unit m/z next to the parent peak. The heights of smaller peak (P M+1 , P M+2 , ... ) compared with the height of parent peak (P M ) depend on the atom and its relative heavy isotopes. Hence, the relative peak heights could designate molecular formula of the substance. A computer application will help in producing a list of all possible molecular formulas from inputs of molecular ion peak results from mass spectrometry. The program calculates relative peak heights implementing Beynon rule. The output becomes a tool for choosing the actual formula of the substance. Although the formula algorithm could be implemented in all chemical groups, the computer program is purely made for an organic substance consists of carbon, hydrogen, oxygen and nitrogen. The computer outputs will inform the odd or even of ionic pairs and the number of bond and rings in the substance also. (author)

  14. Characterization of nitrated sugar alcohols by atmospheric-pressure chemical-ionization mass spectrometry.

    Science.gov (United States)

    Ostrinskaya, Alla; Kelley, Jude A; Kunz, Roderick R

    2017-02-28

    The nitrated sugar alcohols mannitol hexanitrate (MHN), sorbitol hexanitrate (SHN) and xylitol pentanitrate (XPN) are in the same class of compounds as the powerful military-grade explosive pentaerythritol tetranitrate (PETN) and the homemade explosive erythritol tetranitrate (ETN) but, unlike for PETN and ETN, ways to detect MHN, SHN and XPN by mass spectrometry (MS) have not been fully investigated. Atmospheric-pressure chemical-ionization mass spectrometry (APCI-MS) was used to detect ions characteristic of nitrated sugar alcohols. APCI time-of-flight mass spectrometry (APCI-TOF MS) and collision-induced dissociation tandem mass spectrometry (CID MS/MS) were used for confirmation of each ion assignment. In addition, the use of the chemical ionization reagent dichloromethane was investigated to improve sensitivity and selectivity for detection of MHN, SHN and XPN. All the nitrated sugar alcohols studied followed similar fragmentation pathways in the APCI source. MHN, SHN and XPN were detectable as fragment ions formed by the loss of NO 2 , HNO 2 , NO 3 , and CH 2 NO 2 groups, and in the presence of dichloromethane chlorinated adduct ions were observed. It was determined that in MS/MS mode, chlorinated adducts of MHN and SHN had the lowest limits of detection (LODs), while for XPN the lowest LOD was for the [XPN-NO 2 ] - fragment ion. Partially nitrated analogs of each of the three compounds were also present in the starting materials, and ions attributable to these compounds versus those formed from in-source fragmentation of MHN, SHN, and XPN were distinguished and assigned using liquid chromatography APCI-MS and ESI-MS. The APCI-MS technique provides a selective and sensitive method for the detection of nitrated sugar alcohols. The methods disclosed here will benefit the area of explosives trace detection for counterterrorism and forensics. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Chromatography and mass spectrometry of chemical warfare agents, toxins and related compounds: state of the art and future prospects

    NARCIS (Netherlands)

    Kientz, C.E.

    1998-01-01

    Methods for the identification of chemical warfare agents, toxins, bioregulators and related products are frequently reported in literature. These methods are often based on instrumental analysis using chromatography (gas and liquid) and mass spectrometry. Here, these instrumental techniques are

  16. Disposal regulations and techniques applicable to devices using ionising radiation

    International Nuclear Information System (INIS)

    Vidal, J.P.

    1998-01-01

    L'office de Protection contre les rayonnement ionisants, being a government body under the supervision of Ministry of Health and Labour, among other different missions controls the compliance of radiation protection laws with the aim to guarantee the safe operation of equipment using ionising radiation sources. These regulations concerning competence of personnel, especially in the field of medicine or application of ionising radiation on humans, are restricted only to medical doctors (or dentists in their domain) by technical constraints dealing with design of equipment and its exploitation. At the same time regulations define conditions of permanent control in order to verify compliance of radiation protection laws

  17. Innershell ionisation at small impactparameters in proton-atom collisions

    International Nuclear Information System (INIS)

    Duinker, W.

    1981-01-01

    This thesis concentrates on innershell ionisation in proton-atom collisions. An experiment on K-shell ionisation of argon is described, performed in a gasfilled collision chamber under single collision conditions. Further experiments with carbon and aluminium were performed, the K-shell vacancy production in the collision of protons with these atoms being detected through the measurement of Auger-electrons. A spectrometer with a large solid angle was specially constructed for this and its performance is described. K-shell ionisation accompanying nuclear (p,γ) reactions has also been measured using 26 Mg and 27 Al. (Auth./C.F.)

  18. Photochemistry of limonene secondary organic aerosol studied with chemical ionization mass spectrometry

    Science.gov (United States)

    Pan, Xiang

    Limonene is one of the most abundant monoterpenes in the atmosphere. Limonene easily reacts with gas-phase oxidants in air such as NO3, ozone and OH. Secondary organic aerosol (SOA) is formed when low vapor pressure products condense into particles. Chemicals in SOA particles can undergo further reactions with oxidants and with solar radiation that significantly change SOA composition over the course of several days. The goal of this work was to characterize radiation induced reaction in SOA. To perform experiments, we have designed and constructed an Atmospheric Pressure Chemical Ionization Mass Spectrometer (APCIMS) coupled to a photochemical cell containing SOA samples. In APCIMS, (H2O)nH 3O+ clusters are generated in a 63Ni source and react with gaseous organic analytes. Most organic chemicals are not fragmented by the ionization process. We have focused our attention on limonene SOA prepared in two different ways. The first type of SOA is produced by oxidation of limonene by ozone; and the second type of SOA is formed by the NO3-induced oxidation of limonene. They model the SOA formed under daytime and nighttime conditions, respectively. Ozone initiated oxidation is the most important chemical sink for limonene both indoors, where it is used for cleaning purposes, and outdoors. Terpenes are primarily oxidized by reactions with NO3 at night time. We generated limonene SOA under different ozone and limonene concentrations. The resulting SOA samples were exposed to wavelength-tunable radiation in the UV-Visible range between 270 nm and 630 nm. The results show that the photodegradation rates strongly depend on radiation wavelengths. Gas phase photodegradation products such as acetone, formaldehyde, acetaldehyde, and acetic acid were shown to have different production rates for SOA formed in different concentration conditions. Even for SOA prepared under the lowest concentrations, the SOA photodegradation was efficient. The conclusion is that exposure of SOA to

  19. Chemical composition measurements of the atmosphere of Jupiter with the Galileo Probe mass spectrometer

    Science.gov (United States)

    Niemann, H. B.; Atreya, S. K.; Carignan, G. R.; Donahue, T. M.; Haberman, J. A.; Harpold, D. N.; Hartle, R. E.; Hunten, D. M.; Kasprzak, W. T.; Mahaffy, P. R.; hide

    1998-01-01

    The Galileo Probe entered the atmosphere of Jupiter on December 7, 1995. Measurements of the chemical and isotopic composition of the Jovian atmosphere were obtained by the mass spectrometer during the descent over the 0.5 to 21 bar pressure region over a time period of approximately 1 hour. The sampling was either of atmospheric gases directly introduced into the ion source of the mass spectrometer through capillary leaks or of gas, which had been chemically processed to enhance the sensitivity of the measurement to trace species or noble gases. The analysis of this data set continues to be refined based on supporting laboratory studies on an engineering unit. The mixing ratios of the major constituents of the atmosphere hydrogen and helium have been determined as well as mixing ratios or upper limits for several less abundant species including: methane, water, ammonia, ethane, ethylene, propane, hydrogen sulfide, neon, argon, krypton, and xenon. Analysis also suggests the presence of trace levels of other 3 and 4 carbon hydrocarbons, or carbon and nitrogen containing species, phosphine, hydrogen chloride, and of benzene. The data set also allows upper limits to be set for many species of interest which were not detected. Isotope ratios were measured for 3He/4He, D/H, 13C/12C, 20Ne/22Ne, 38Ar/36Ar and for isotopes of both Kr and Xe.

  20. High-throughput peptide mass fingerprinting and protein macroarray analysis using chemical printing strategies

    International Nuclear Information System (INIS)

    Sloane, A.J.; Duff, J.L.; Hopwood, F.G.; Wilson, N.L.; Smith, P.E.; Hill, C.J.; Packer, N.H.; Williams, K.L.; Gooley, A.A.; Cole, R.A.; Cooley, P.W.; Wallace, D.B.

    2001-01-01

    We describe a 'chemical printer' that uses piezoelectric pulsing for rapid and accurate microdispensing of picolitre volumes of fluid for proteomic analysis of 'protein macroarrays'. Unlike positive transfer and pin transfer systems, our printer dispenses fluid in a non-contact process that ensures that the fluid source cannot be contaminated by substrate during a printing event. We demonstrate automated delivery of enzyme and matrix solutions for on-membrane protein digestion and subsequent peptide mass fingerprinting (pmf) analysis directly from the membrane surface using matrix-assisted laser-desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS). This approach bypasses the more commonly used multi-step procedures, thereby permitting a more rapid procedure for protein identification. We also highlight the advantage of printing different chemistries onto an individual protein spot for multiple microscale analyses. This ability is particularly useful when detailed characterisation of rare and valuable sample is required. Using a combination of PNGase F and trypsin we have mapped sites of N-glycosylation using on-membrane digestion strategies. We also demonstrate the ability to print multiple serum samples in a micro-ELISA format and rapidly screen a protein macroarray of human blood plasma for pathogen-derived antigens. We anticipate that the 'chemical printer' will be a major component of proteomic platforms for high-throughput protein identification and characterisation with widespread applications in biomedical and diagnostic discovery

  1. Chemical mass balance source apportionment of fine and PM10 in the Desert Southwest, USA

    Directory of Open Access Journals (Sweden)

    Andrea L. Clements

    2016-03-01

    Full Text Available The Desert Southwest Coarse Particulate Matter Study was undertaken in Pinal County, Arizona, to better understand the origin and impact of sources of fine and coarse particulate matter (PM in rural, arid regions of the U.S. southwestern desert. The desert southwest experiences some of the highest PM10 mass concentrations in the country. To augment previously reported results, 6-week aggregated organic speciation data that included ambient concentrations of n-alkanes, polycyclic aromatic hydrocarbons, organic acids, and saccharides were used in chemical mass balance modeling (CMB. A set of re-suspended soil samples were analyzed for specific marker species to provide locally-appropriate source profiles for the CMB analysis. These profiles, as well as previously collected plant and fungal spore profiles from the region, were combined with published source profiles for other relevant sources and used in the CMB analysis. The six new region-specific source profiles included both organic and inorganic species for four crustal material sources, one plant detritus source, and one fungal spore source.Results indicate that up to half of the ambient PM2.5 was apportioned to motor vehicles with the highest regional contribution observed in the small urban center of Casa Grande. Daily levels of apportioned crustal material accounted for up to 50% of PM2.5 mass with the highest contributions observed at the sites closest to active agricultural areas. Apportioned secondary PM, biomass burning, and road dust typically contributed less than 35% as a group to the apportioned PM2.5 mass. Crustal material was the primary source apportioned to PM10 and accounted for between 50–90% of the apportioned mass. Of the other sources apportioned to PM10, motor vehicles and road dust were the largest contributors at the urban and one of the rural sites, whereas road dust and meat cooking operations were the largest contributors at the other rural site.

  2. The effects of the initial mass function on the chemical evolution of elliptical galaxies

    Science.gov (United States)

    De Masi, Carlo; Matteucci, F.; Vincenzo, F.

    2018-03-01

    We describe the use of our chemical evolution model to reproduce the abundance patterns observed in a catalogue of elliptical galaxies from the Sloan Digital Sky Survey Data Release 4. The model assumes ellipticals form by fast gas accretion, and suffer a strong burst of star formation followed by a galactic wind, which quenches star formation. Models with fixed initial mass function (IMF) failed in simultaneously reproducing the observed trends with the galactic mass. So, we tested a varying IMF; contrary to the diffused claim that the IMF should become bottom heavier in more massive galaxies, we find a better agreement with data by assuming an inverse trend, where the IMF goes from being bottom heavy in less massive galaxies to top heavy in more massive ones. This naturally produces a downsizing in star formation, favouring massive stars in largest galaxies. Finally, we tested the use of the integrated Galactic IMF, obtained by averaging the canonical IMF over the mass distribution function of the clusters where star formation is assumed to take place. We combined two prescriptions, valid for different SFR regimes, to obtain the Integrated Initial Mass Function values along the whole evolution of the galaxies in our models. Predicted abundance trends reproduce the observed slopes, but they have an offset relative to the data. We conclude that bottom-heavier IMFs do not reproduce the properties of the most massive ellipticals, at variance with previous suggestions. On the other hand, an IMF varying with galactic mass from bottom heavier to top heavier should be preferred.

  3. Chemical characterization of microparticles by laser ablation in an ion trap mass spectrometer

    International Nuclear Information System (INIS)

    Dale, J.M.; Whitten, W.B.; Ramsey, J.M.

    1991-01-01

    We are developing a new technique for the chemical characterization of microparticles based upon the use of electrodynamic traps. The electrodynamic trap has achieved widespread use in the mass spectrometry community in the form of the ion trap mass spectrometer or quadrupole ion trap. Small macroscopic particles can be confined or leviated within the electrode structure of a three-dimensional quadrupole electrodynamic trap in the same way as fundamental charges or molecular ions by using a combination of ac and dc potentials. Our concept is to use the same electrode structure to perform both microparticle levitation and ion trapping/mass analysis. The microparticle will first be trapped and spatially stabilized within the trap for characterization by optical probes, i.e., absorption, fluorescence, or Raman spectroscopy. After the particle has been optically characterized, it is further characterized using mass spectrometry. Ions are generated from the particle surface using laser ablation or desorption. The characteristics of the applied voltages are changed to trap the ions formed by the laser with the ions subsequently mass analyzed. The work described in this paper focuses on the ability to perform laser desorption experiments on microparticles contained within the ion trap. Laser desorption has previously been demonstrated in ion trap devices by applying the sample to a probe which is inserted so as to place the sample at the surface of the ring electrode. Our technique requires the placement of a microparticle in the center of the trap. Our initial experiments have been performed on falling microparticles rather than levitated particles to eliminate voltage switching requirements when changing from particle to ion trapping modes

  4. Stereoselective quantification of methadone and a d(6)-labeled isotopomer using high performance liquid chromatography-atmospheric pressure chemical ionization mass-spectrometry: application to a pharmacokinetic study in a methadone maintained subject.

    Science.gov (United States)

    Foster, David J R; Morton, Erin B; Heinkele, Georg; Mürdter, Thomas E; Somogyi, Andrew A

    2006-08-01

    There is evidence that the apparent oral clearance of rac-methadone is induced during the early phase of methadone maintenance treatment. However, it is not known if this is due to changes in bioavailability or if this phenomenon is stereoselective. This knowledge can be obtained by administering a dose of stable-labeled methadone at selected times during ongoing treatment. Therefore, the authors developed a stereoselective high performance liquid chromatography-atmospheric pressure chemical ionization mass-spectrometry assay for the quantification of the enantiomers of methadone and a d(6)-labeled isotopomer. The compounds were quantified in a single assay after liquid-liquid extraction and stereoselective high performance liquid chromatograph with atmospheric pressure chemical ionization-mass spectrometry detection. The following ions were monitored: m/z 310.15 for unlabeled methadone; m/z 316.15 for methadone-d(6); and m/z 313.15 for the methadone-d(3) (internal standard). Calibration curves ranged from 0.5 to 75 ng/mL for each compound. Extraction recovery was approximately 80% for all analytes, without evidence of differences between the unlabeled and stable-labeled compounds or concentration dependency. Minor ion promotion was observed (d(3)-labeled internal standard, with peak area ratios in extracted samples identical to control injections. The isotopomers did not alter each others' ionisation, even at 10:1 concentration ratios, and 10-fold diluted samples were within 10% of the nominal concentration. Assay performance was acceptable, with interassay and intra-assay bias and precision d(6) in a patient receiving chronic oral methadone maintenance therapy.

  5. Bi-Abundance Ionisation Structure of the Wolf-Rayet Planetary Nebula PB 8

    Science.gov (United States)

    Danehkar, A.

    2018-01-01

    The planetary nebula PB 8 around a [WN/WC]-hybrid central star is one of planetary nebulae with moderate abundance discrepancy factors (ADFs 2-3), which could be an indication of a tiny fraction of metal-rich inclusions embedded in the nebula (bi-abundance). In this work, we have constructed photoionisation models to reproduce the optical and infrared observations of the planetary nebula PB 8 using a non-LTE stellar model atmosphere ionising source. A chemically homogeneous model initially used cannot predict the optical recombination lines. However, a bi-abundance model provides a better fit to most of the observed optical recombination lines from N and O ions. The metal-rich inclusions in the bi-abundance model occupy 5.6% of the total volume of the nebula, and are roughly 1.7 times cooler and denser than the mean values of the surrounding nebula. The N/H and O/H abundance ratios in the metal-rich inclusions are 1.0 and 1.7 dex larger than the diffuse warm nebula, respectively. To reproduce the Spitzer spectral energy distribution of PB 8, dust grains with a dust-to-gas ratio of 0.01 (by mass) were also included. It is found that the presence of metal-rich inclusions can explain the heavy element optical recombination lines, while a dual-dust chemistry with different grain species and discrete grain sizes likely produces the infrared continuum of this planetary nebula. This study demonstrates that the bi-abundance hypothesis, which was examined in a few planetary nebulae with large abundance discrepancies (ADFs > 10), could also be applied to those typical planetary nebulae with moderate abundance discrepancies.

  6. Microporous hollow fibre membrane modules as gas-liquid contactors. Part 2. Mass transfer with chemical reaction

    NARCIS (Netherlands)

    Kreulen, H.; Versteeg, G.F.; Swaaij, W.P.M. van

    1993-01-01

    Absorption determined by mass transfer in the liquid is described well with the Graetz-Lévèque equation adapted from heat transfer. The influence of a chemical reaction on the mass transfer was simulated with a numerical model and tested on the absorption of CO2 in a hydroxide solution. Absorption

  7. Chemical crosslinking and mass spectrometry studies of the structure and dynamics of membrane proteins and receptors.

    Energy Technology Data Exchange (ETDEWEB)

    Haskins, William E.; Leavell, Michael D.; Lane, Pamela; Jacobsen, Richard B.; Hong, Joohee; Ayson, Marites J.; Wood, Nichole L.; Schoeniger, Joseph S.; Kruppa, Gary Hermann; Sale, Kenneth L.; Young, Malin M.; Novak, Petr

    2005-03-01

    Membrane proteins make up a diverse and important subset of proteins for which structural information is limited. In this study, chemical cross-linking and mass spectrometry were used to explore the structure of the G-protein-coupled photoreceptor bovine rhodopsin in the dark-state conformation. All experiments were performed in rod outer segment membranes using amino acid 'handles' in the native protein sequence and thus minimizing perturbations to the native protein structure. Cysteine and lysine residues were covalently cross-linked using commercially available reagents with a range of linker arm lengths. Following chemical digestion of cross-linked protein, cross-linked peptides were identified by accurate mass measurement using liquid chromatography-fourier transform mass spectrometry and an automated data analysis pipeline. Assignments were confirmed and, if necessary, resolved, by tandem MS. The relative reactivity of lysine residues participating in cross-links was evaluated by labeling with NHS-esters. A distinct pattern of cross-link formation within the C-terminal domain, and between loop I and the C-terminal domain, emerged. Theoretical distances based on cross-linking were compared to inter-atomic distances determined from the energy-minimized X-ray crystal structure and Monte Carlo conformational search procedures. In general, the observed cross-links can be explained by re-positioning participating side-chains without significantly altering backbone structure. One exception, between C3 16 and K325, requires backbone motion to bring the reactive atoms into sufficient proximity for cross-linking. Evidence from other studies suggests that residues around K325 for a region of high backbone mobility. These findings show that cross-linking studies can provide insight into the structural dynamics of membrane proteins in their native environment.

  8. Chemical analysis and genotoxicity of high molecular mass PAH in sediment samples and biota

    International Nuclear Information System (INIS)

    McCarry, B.E.; Marvin, C.H.; Smith, R.W.; Bryant, D.W.

    1995-01-01

    A normal phase liquid chromatography (NPLC) method was used to fractionate the organic extracts of prepared from coal tar-contaminated sediments from hamilton Harbor in Ontario and from Sydney Harbor in Nova Scotia into molecular mass classes. Each PAH fraction up to 302 amu was analyzed by GC-MS and fractions containing PAH with molecular masses greater than 302 amu were analyzed by atmospheric pressure chemical ionization (APCI) LC-MS.Each fraction was also subjected to Ames bioassays using a TA100-like strain of Salmonella typhimurium (YG1025 + S9). The 300/302 amu, 326/328 and 350/352 amu PAH fractions accounted for 25% of the total genotoxic response of the extract; these PAH constitute a substantial genotoxic burden. A number of 300, 302, 326, 350, 374 and 400 amu PAH were identified using APCI LC-MS and comparison with authentic standards. The non-polar aromatic extracts of bottom sediments, suspended sediments and zebra mussels from Hamilton Harbor were also examined by GC-MS, APCI LC-MS and genotoxicity bioassays. The profiles of the priority and high mass PAH in these samples were identical showing that all PAH up to and exceeding 400 amu were readily bioavailable to biota such as Zebra mussels. In addition, the pseudo faeces of the Zebra mussels and amphipod detritivores which fed on the pseudo faeces had chemical profiles identical to the Zebra mussels. Since many sport fish prize amphipods as food, this observation demonstrates a pathway for organic contaminants adsorbed to suspended sediments to enter the food chain of non-bottom-feeding fish in areas infested by Zebra mussels

  9. Oligomerisation of Synaptobrevin-2 Studied by Native Mass Spectrometry and Chemical Cross-Linking

    Science.gov (United States)

    Wittig, Sabine; Haupt, Caroline; Hoffmann, Waldemar; Kostmann, Susann; Pagel, Kevin; Schmidt, Carla

    2018-06-01

    Synaptobrevin-2 is a key player in signal transmission in neurons. It forms, together with SNAP25 and Syntaxin-1A, the neuronal soluble N-ethylmaleimide-sensitive factor attachment protein receptor (SNARE) complex and mediates exocytosis of synaptic vesicles with the pre-synaptic membrane. While Synaptobrevin-2 is part of a four-helix bundle in this SNARE complex, it is natively unstructured in the absence of lipids or other SNARE proteins. Partially folded segments, presumably SNARE complex formation intermediates, as well as formation of Synaptobrevin-2 dimers and oligomers, were identified in previous studies. Here, we employ three Synaptobrevin-2 variants—the full-length protein Syb(1-116), the soluble, cytosolic variant Syb(1-96) as well as a shorter version Syb(49-96) containing structured segments but omitting a trigger site for SNARE complex formation—to study oligomerisation in the absence of interaction partners or when incorporated into the lipid bilayer of liposomes. Combining native mass spectrometry with chemical cross-linking, we find that the truncated versions show increased oligomerisation. Our findings from both techniques agree well and confirm the presence of oligomers in solution while membrane-bound Synaptobrevin-2 is mostly monomeric. Using ion mobility mass spectrometry, we could further show that lower charge states of Syb(49-96) oligomers, which most likely represent solution structures, follow an isotropic growth curve suggesting that they are intrinsically disordered. From a technical point of view, we show that the combination of native ion mobility mass spectrometry with chemical cross-linking is well-suited for the analysis of protein homo-oligomers. [Figure not available: see fulltext.

  10. Direct Laser Ablation and Ionization of Solids for Chemical Analysis by Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Holt, J K; Nelson, E J; Klunder, G L [Forensic Science Center, Lawrence Livermore National Laboratory, Livermore, CA 94551 (United States)

    2007-04-15

    A laser ablation/ionization mass spectrometer system is described for the direct chemical analysis of solids. An Nd:YAG laser is used for ablation and ionization of the sample in a quadrupole ion trap operated in an ion-storage (IS) mode that is coupled with a reflectron time-of-flight mass spectrometer (TOF-MS). Single pulse experiments have demonstrated simultaneous detection of up to 14 elements present in glasses in the ppm range. However, detection of the components has produced non-stoichiometric results due to difference in ionization potentials and fractionation effects. Time-of-flight secondary ionization mass spectrometry (TOF-SIMS) was used to spatially map elemental species on the surface and provide further evidence of fractionation effects. Resolution (m/{delta}m) of 1500 and detection limits of approximately 10 pg have been achieved with a single laser pulse. The system configuration and related operating principles for accurately measuring low concentrations of isotopes are described.

  11. Atmospheric pressure chemical ionization Fourier transform ion cyclotron resonance mass spectrometry for complex thiophenic mixture analysis

    KAUST Repository

    Hourani, Nadim

    2013-10-01

    Rationale Polycyclic aromatic sulfur heterocycles (PASHs) are detrimental species for refining processes in petroleum industry. Current mass spectrometric Methods that determine their composition are often preceded by derivatization and dopant addition approaches. Different ionization Methods have different impact on the molecular assignment of complex PASHs. The analysis of such species under atmospheric pressure chemical ionization (APCI) is still considered limited due to uncontrolled ion generation with low- and high-mass PASHs. Methods The ionization behavior of a model mixture of five selected PASH standards was investigated using an APCI source with nitrogen as the reagent gas. A complex thiophenic fraction was separated from a vacuum gas oil (VGO) and injected using the same method. The samples were analyzed using Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS). RESULTS PASH model analytes were successfully ionized and mainly [M + H]+ ions were produced. The same ionization pattern was observed for the real thiophenic sample. It was found that S1 class species were the major sulfur-containing species found in the VGO sample. These species indicated the presence of alkylated benzothiophenic (BT), dibenzothiophenic (DBT) and benzonaphthothiophenic (BNT) series that were detected by APCI-FTICR MS. CONCLUSIONS This study provides an established APCI-FTICR MS method for the analysis of complex PASHs. PASHs were detected without using any derivatization and without fragmentation. The method can be used for the analysis of S-containing crude oil samples. © 2013 John Wiley & Sons, Ltd.

  12. Autonomous bio-chemical decontaminator (ABCD) against weapons of mass destruction

    Science.gov (United States)

    Hyacinthe, Berg P.

    2006-05-01

    The proliferation of weapons of mass destruction (WMD) and the use of such elements pose an eminent asymmetric threat with disastrous consequences to the national security of any nation. In particular, the use of biochemical warfare agents against civilians and unprotected troops in international conflicts or by terrorists against civilians is considered as a very peculiar threat. Accordingly, taking a quarantine-before-inhalation approach to biochemical warfare, the author introduces the notion of autonomous biochemical decontamination against WMD. In the unfortunate event of a biochemical attack, the apparatus proposed herein is intended to automatically detect, identify, and more importantly neutralize a biochemical threat. Along with warnings concerning a cyber-WMD nexus, various sections cover discussions on human senses and computer sensors, corroborating evidence related to detection and neutralization of chemical toxins, and cyber-assisted olfaction in stand alone, peer-to-peer, and network settings. In essence, the apparatus can be used in aviation and mass transit security to initiate mass decontamination by dispersing a decontaminant aerosol or to protect the public water supply against a potential bioterrorist attack. Future effort may involve a system-on-chip (SoC) embodiment of this apparatus that allows a safer environment for the emerging phenomenon of cyber-assisted olfaction and morph cell phones into ubiquitous sensors/decontaminators. Although this paper covers mechanisms and protocols to avail a neutralizing substance, further research will need to explore the substance's various pharmacological profiles and potential side effects.

  13. Health Services management. Health Service use of ionising radiations

    International Nuclear Information System (INIS)

    1989-12-01

    This circular consolidates and updates advice on the statutory and management responsibilities of Health Authorities in relation to the use of ionising radiations (including radioactive substances) on premises controlled by them and/or by persons employed by them (author)

  14. Working Group on Ionising Radiations. Report 1987-88

    International Nuclear Information System (INIS)

    1989-01-01

    The programme of work for 1987/88 by the Working Group on Ionising Radiation, Health and Safety Commision in February 1988, included the main topics of continuing interest and concern in relation to ionising radiations in general and the Ionising Radiations Regulations 1985 (IRR 85) (Ref 1) in particular. These were: emergency dose limitation, occupational dose limitation, practical experience of the principle of keeping doses as low as reasonably practicable, experience of the regulatory requirements in respect of internal dosimetry and the need for a standing advisory committee on ionising radiations. Calibration of radiotherapy equipment was also considered as a matter of principle following a specific incident involving cancer patients. This report of progress during the first year summarises the Group's opinions on each topic and gives recommendations. (author)

  15. In-medium Modifications of Hadron Masses and Chemical Freeze-out in Ultra-relativistic Heavy-ion Collisions

    International Nuclear Information System (INIS)

    Florkowski, W.; Broniowski, W.

    1999-10-01

    We confront the hypothesis of chemical freeze-out in ultra-relativistic heavy-ion collisions with the hypothesis of large modifications of hadron masses in nuclear medium. We find that the thermal-model predictions for the ratios of particle multiplicities are sensitive to the values of in-medium hadronic masses. In particular, the π + /p ratio decreases by 35% when the masses of all hadrons (except for pseudo-Goldstone bosons) are scaled down by 30%. (author)

  16. Time-of-flight secondary ion mass spectrometry with energetic cluster ion impact ionization for highly sensitive chemical structure characterization

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, K., E-mail: k.hirata@aist.go.jp [National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki 305-8565 (Japan); Saitoh, Y.; Chiba, A.; Yamada, K.; Narumi, K. [Takasaki Advanced Radiation Research Institute (TARRI), Japan Atomic Energy Agency (JAEA), Takasaki, Gumma 370-1292 (Japan)

    2013-11-01

    Energetic cluster ions with energies of the order of sub MeV or greater were applied to time-of-flight (TOF) secondary ion (SI) mass spectrometry. This gave various advantages including enhancement of SIs required for chemical structure characterization and prevention of charging effects in SI mass spectra for organic targets. We report some characteristic features of TOF SI mass spectrometry using energetic cluster ion impact ionization and discuss two future applications of it.

  17. Ionisation and dissociation of water induced by swift multicharged ions

    International Nuclear Information System (INIS)

    Legendre, S.

    2006-02-01

    Ionization and dissociation of water molecules and water clusters induced by 11.7 MeV/A Ni 25+ ions were carried out by imaging techniques. Branching ratios, ionisation cross sections and Kinetic Energy Released distributions have been measured together with fragmentation dynamics studies. Multiple ionization represents approximately 30% of the ionizing events. Double ionization produces in significant way atomic oxygen, considered as a possible precursor of the large production of HO 2 radical in liquid water radiolysis by ions of high Linear Energy Transfer. We evidence a strong selectivity of bond breakage in the case of ion-induced HOD fragmentation. Once the molecule doubly ionized, the breakage of the O-H bond is found 6.5 times more probable than that of the O-D bond. A semi-classical calculation simulating the fragmentation dynamics on the potential energy surface of the ground-state of di-cation H 2 O 2+ makes possible to as well reproduce the preferential nature of the breakage of the O-H bond as the position and the shift of the kinetic energy distributions. First results concerning interaction with water clusters are also reported. Measurements in coincidence are carried out giving access to correlation, with the distributions in energy and angle of the emitted fragments. Mass spectrum points fast intra-cluster proton transfer, leading to the emission of protonated clusters. (author)

  18. Detection of Chemical/Biological Agents and Stimulants using Quadrupole Ion Trap Mass Spectrometry

    International Nuclear Information System (INIS)

    Harmon, S.H.; Hart, K.J.; Vass, A.A.; Wise, M.B.; Wolf, D.A.

    1999-01-01

    Detection of Chemical/Biological Agents and Simulants A new detector for chemical and biological agents is being developed for the U. S. Army under the Chemical and Biological Mass Spectrometer Block II program. The CBMS Block II is designed to optimize detection of both chemical and biological agents through the use of direct sampling inlets[I], a multi- ported sampling valve and a turbo- based vacuum system to support chemical ionization. Unit mass resolution using air as the buffer gas[2] has been obtained using this design. Software to control the instrument and to analyze the data generated from the instrument has also been newly developed. Detection of chemical agents can be accomplished. using the CBMS Block II design via one of two inlets - a l/ I 6'' stainless steel sample line -Chemical Warfare Air (CW Air) or a ground probe with enclosed capillary currently in use by the US Army - CW Ground. The Block II design is capable of both electron ionization and chemical ionization. Ethanol is being used as the Cl reagent based on a study indicating best performance for the Biological Warfare (BW) detection task (31). Data showing good signal to noise for 500 pg of methyl salicylate injected into the CW Air inlet, 50 ng of dimethylmethylphosphonate exposed to the CW Ground probe and 5 ng of methyl stearate analyzed using the pyrolyzer inlet were presented. Biological agents are sampled using a ''bio-concentrator'' unit that is designed to concentrate particles in the low micron range. Particles are collected in the bottom of a quartz pyrolyzer tube. An automated injector is being developed to deliver approximately 2 pL of a methylating reagent, tetramethylamonium- hydroxide to 'the collected particles. Pyrolysis occurs by rapid heating to ca. 55OOC. Biological agents are then characterized by their fatty acid methyl ester profiles and by other biomarkers. A library of ETOH- Cl/ pyrolysis MS data of microorganisms used for a recently published study[3] has been

  19. Cluster chemical ionization for improved confidence level in sample identification by gas chromatography/mass spectrometry.

    Science.gov (United States)

    Fialkov, Alexander B; Amirav, Aviv

    2003-01-01

    Upon the supersonic expansion of helium mixed with vapor from an organic solvent (e.g. methanol), various clusters of the solvent with the sample molecules can be formed. As a result of 70 eV electron ionization of these clusters, cluster chemical ionization (cluster CI) mass spectra are obtained. These spectra are characterized by the combination of EI mass spectra of vibrationally cold molecules in the supersonic molecular beam (cold EI) with CI-like appearance of abundant protonated molecules, together with satellite peaks corresponding to protonated or non-protonated clusters of sample compounds with 1-3 solvent molecules. Like CI, cluster CI preferably occurs for polar compounds with high proton affinity. However, in contrast to conventional CI, for non-polar compounds or those with reduced proton affinity the cluster CI mass spectrum converges to that of cold EI. The appearance of a protonated molecule and its solvent cluster peaks, plus the lack of protonation and cluster satellites for prominent EI fragments, enable the unambiguous identification of the molecular ion. In turn, the insertion of the proper molecular ion into the NIST library search of the cold EI mass spectra eliminates those candidates with incorrect molecular mass and thus significantly increases the confidence level in sample identification. Furthermore, molecular mass identification is of prime importance for the analysis of unknown compounds that are absent in the library. Examples are given with emphasis on the cluster CI analysis of carbamate pesticides, high explosives and unknown samples, to demonstrate the usefulness of Supersonic GC/MS (GC/MS with supersonic molecular beam) in the analysis of these thermally labile compounds. Cluster CI is shown to be a practical ionization method, due to its ease-of-use and fast instrumental conversion between EI and cluster CI, which involves the opening of only one valve located at the make-up gas path. The ease-of-use of cluster CI is analogous

  20. Effects of small doses of ionising radiation

    International Nuclear Information System (INIS)

    Doll, R.

    1998-01-01

    Uncertainty remains about the quantitative effects of doses of ionising radiation less than 0.2 Sv. Estimates of hereditary effects, based on the atomic bomb survivors, suggest that the mutation doubling dose is about 2 Sv for acute low LET radiation, but the confidence limits are wide. The idea that paternal gonadal irradiation might explain the Seascale cluster of childhood leukaemia has been disproved. Fetal irradiation may lead to a reduction in IQ and an increase in seizures in childhood proportional to dose. Estimates that doses to a whole population cause a risk of cancer proportional to dose, with 0.1 Sv given acutely causing a risk of 1%, will need to be modified as more information is obtained, but the idea that there is a threshold for risk above this level is not supported by observations on the irradiated fetus or the effect of fallout. The idea, based on ecological observations, that small doses protect against the development of cancer is refuted by the effect of radon in houses. New observations on the atomic bomb survivors have raised afresh the possibility that small doses may also have other somatic effects. (author)

  1. Synthesis and Characterization of Mass Produced High Quality Few Layered Graphene Sheets via a Chemical Method

    KAUST Repository

    Khenfouch, Mohammed

    2014-04-01

    Graphene is a two-dimensional crystal of carbon atoms arranged in a honeycomb lattice. It is a zero band gap semimetal with very unique physical and chemical properties which make it useful for many applications such as ultra-high-speed field-effect transistors, p-n junction diodes, terahertz oscillators, and low-noise electronic, NEMS and sensors. When the high quality mass production of this nanomaterial is still a big challenge, we developed a process which will be an important step to achieve this goal. Atomic Force Microscopy, Scanning Electron Microscopy, Scanning tunneling microscopy, High Resolution Transmission Electron Microscopy, X-Ray Diffraction, Raman spectroscopy, Energy Dispersive X-ray system were investigated to characterize and examine the quality of this product.

  2. Terror weapons. Ridding the world of nuclear, biological and chemical weapons - Commission on mass destruction weapons

    International Nuclear Information System (INIS)

    Blix, H.; Journe, V.

    2010-01-01

    This book approaches in 8 chapters the ambitious challenge of ridding the world of all mass destruction weapons: 1 - re-launching disarmament; 2 - terror weapons: nature of threats and answers (weakness of traditional answers, counter-proliferation); 3 - nuclear weapons: preventing proliferation and terrorism, reducing threat and nuclear weapons number, from regulation to banning); 4 - biological or toxin weapons; 5 - chemical weapons; 6 - vectors, anti-missile defenses and space weapons; 7 - exports control, international assistance and non-governmental actors; 8 - respect, verification, enforcement and role of the United Nations. The recommendations and works of the Commission are presented in appendix together with the declaration adopted on April 30, 2009. (J.S.)

  3. Mass-Spectrometric Studies of Catalytic Chemical Vapor Deposition Processes of Organic Silicon Compounds Containing Nitrogen

    Science.gov (United States)

    Morimoto, Takashi; Ansari, S. G.; Yoneyama, Koji; Nakajima, Teppei; Masuda, Atsushi; Matsumura, Hideki; Nakamura, Megumi; Umemoto, Hironobu

    2006-02-01

    The mechanism of catalytic chemical vapor deposition (Cat-CVD) processes for hexamethyldisilazane (HMDS) and trisdimethylaminosilane (TDMAS), which are used as source gases to prepare SiNx or SiCxNy films, was studied using three different mass spectrometric techniques: ionization by Li+ ion attachment, vacuum-ultraviolet radiation and electron impact. The results for HMDS show that Si-N bonds dissociate selectively, although Si-C bonds are weaker, and (CH3)3SiNH should be one of the main precursors of deposited films. This decomposition mechanism did not change when NH3 was introduced, but the decomposition efficiency was slightly increased. Similar results were obtained for TDMAS.

  4. Heat and mass transfer in turbulent chemically nonequilibrium flow in the tube with boundary second kind conditions. The section with the stabilized heat and mass transfer

    International Nuclear Information System (INIS)

    Kritsuk, E.L.; Mishina, L.V.; Shegidevich, L.N.

    1986-01-01

    The hydrodynamically stabilized chemically nonequilibrium turbulent flow in a tube with the inert impermeable surface and constant specific heat flow on the wall is considered. The reversible homogeneous reaction of nitrogen dioxide dissociation 2NO 2 ↔ 2NO+O 2 takes place in the flow. Chemically equilibrium flow with homogeneous profile of temperature and concentration arrives into the channel inlet. After application of simplifying assumptions, the expressions for characteristics of heat and mass transfer have been written down, which are valid in the whole range of the flow parameter variation from frozen up to chemically equilibrium flow. An integral transformation method is suggested for a radial coordinate which allows a wall region to be extended, thereby essentially extending the step of integration. A solution in quadratures has been obtained for the heat and mass transfer problem in an inert fluid flow for the developed process section. The elimination method has been employed to solve the boundary-value second-kind problem for the function governing heat and mass transfer in a chemically nonequilibrium turbulent flow over the developed heat and mass transfer section. The results of calculations are presented

  5. Chemical discrimination in turbulent gas mixtures with MOX sensors validated by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Fonollosa, Jordi; Rodríguez-Luján, Irene; Trincavelli, Marco; Vergara, Alexander; Huerta, Ramón

    2014-10-16

    Chemical detection systems based on chemo-resistive sensors usually include a gas chamber to control the sample air flow and to minimize turbulence. However, such a kind of experimental setup does not reproduce the gas concentration fluctuations observed in natural environments and destroys the spatio-temporal information contained in gas plumes. Aiming at reproducing more realistic environments, we utilize a wind tunnel with two independent gas sources that get naturally mixed along a turbulent flow. For the first time, chemo-resistive gas sensors are exposed to dynamic gas mixtures generated with several concentration levels at the sources. Moreover, the ground truth of gas concentrations at the sensor location was estimated by means of gas chromatography-mass spectrometry. We used a support vector machine as a tool to show that chemo-resistive transduction can be utilized to reliably identify chemical components in dynamic turbulent mixtures, as long as sufficient gas concentration coverage is used. We show that in open sampling systems, training the classifiers only on high concentrations of gases produces less effective classification and that it is important to calibrate the classification method with data at low gas concentrations to achieve optimal performance.

  6. Reduction of chemical formulas from the isotopic peak distributions of high-resolution mass spectra.

    Science.gov (United States)

    Roussis, Stilianos G; Proulx, Richard

    2003-03-15

    A method has been developed for the reduction of the chemical formulas of compounds in complex mixtures from the isotopic peak distributions of high-resolution mass spectra. The method is based on the principle that the observed isotopic peak distribution of a mixture of compounds is a linear combination of the isotopic peak distributions of the individual compounds in the mixture. All possible chemical formulas that meet specific criteria (e.g., type and number of atoms in structure, limits of unsaturation, etc.) are enumerated, and theoretical isotopic peak distributions are generated for each formula. The relative amount of each formula is obtained from the accurately measured isotopic peak distribution and the calculated isotopic peak distributions of all candidate formulas. The formulas of compounds in simple spectra, where peak components are fully resolved, are rapidly determined by direct comparison of the calculated and experimental isotopic peak distributions. The singular value decomposition linear algebra method is used to determine the contributions of compounds in complex spectra containing unresolved peak components. The principles of the approach and typical application examples are presented. The method is most useful for the characterization of complex spectra containing partially resolved peaks and structures with multiisotopic elements.

  7. Single-neuron identification of chemical constituents, physiological changes, and metabolism using mass spectrometry.

    Science.gov (United States)

    Zhu, Hongying; Zou, Guichang; Wang, Ning; Zhuang, Meihui; Xiong, Wei; Huang, Guangming

    2017-03-07

    The use of single-cell assays has emerged as a cutting-edge technique during the past decade. Although single-cell mass spectrometry (MS) has recently achieved remarkable results, deep biological insights have not yet been obtained, probably because of various technical issues, including the unavoidable use of matrices, the inability to maintain cell viability, low throughput because of sample pretreatment, and the lack of recordings of cell physiological activities from the same cell. In this study, we describe a patch clamp/MS-based platform that enables the sensitive, rapid, and in situ chemical profiling of single living neurons. This approach integrates modified patch clamp technique and modified MS measurements to directly collect and detect nanoliter-scale samples from the cytoplasm of single neurons in mice brain slices. Abundant possible cytoplasmic constituents were detected in a single neuron at a relatively fast rate, and over 50 metabolites were identified in this study. The advantages of direct, rapid, and in situ sampling and analysis enabled us to measure the biological activities of the cytoplasmic constituents in a single neuron, including comparing neuron types by cytoplasmic chemical constituents; observing changes in constituent concentrations as the physiological conditions, such as age, vary; and identifying the metabolic pathways of small molecules.

  8. The potential use of diamond coated tungsten tips as a field ionisation source

    Energy Technology Data Exchange (ETDEWEB)

    Brown, A.; Prawer, S.; Legge, G.J.F.; Kostidis, L.I. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1996-12-31

    Tungsten tips are convenient for use in a high brightness gaseous phase field ionisation source. However, the lifetime of these tips is not adequate for practical use. The authors are investigating whether coating tungsten tips with diamond using Chemical Vapor Deposition (CVD) will improve the practicality of using these tips by an improvement in longevity of the source and/or an improvement in brightness due to the effects of the property of negative electron affinity which has been observed on CVD diamond. 1 ref.

  9. The potential use of diamond coated tungsten tips as a field ionisation source

    Energy Technology Data Exchange (ETDEWEB)

    Brown, A; Prawer, S; Legge, G J.F.; Kostidis, L I [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1997-12-31

    Tungsten tips are convenient for use in a high brightness gaseous phase field ionisation source. However, the lifetime of these tips is not adequate for practical use. The authors are investigating whether coating tungsten tips with diamond using Chemical Vapor Deposition (CVD) will improve the practicality of using these tips by an improvement in longevity of the source and/or an improvement in brightness due to the effects of the property of negative electron affinity which has been observed on CVD diamond. 1 ref.

  10. Odor and odorous chemical emissions from dairy and swine facilities: Part 5-Simultaneous chemical and sensory analysis with Gas Chromatography - Mass Spectrometry - Olfactometry

    Science.gov (United States)

    Simultaneous chemical and sensory analyses using gas chromatography-mass spectrometry-olfactometry (GC-MS-O) for air samples collected at barn exhaust fans were used for quantification and ranking of odor impact of target odorous gases. Fifteen target odorous VOCs (odorants) were selected. Air sampl...

  11. Fast screening of analytes for chemical reactions by reactive low-temperature plasma ionization mass spectrometry.

    Science.gov (United States)

    Zhang, Wei; Huang, Guangming

    2015-11-15

    Approaches for analyte screening have been used to aid in the fine-tuning of chemical reactions. Herein, we present a simple and straightforward analyte screening method for chemical reactions via reactive low-temperature plasma ionization mass spectrometry (reactive LTP-MS). Solution-phase reagents deposited on sample substrates were desorbed into the vapor phase by action of the LTP and by thermal desorption. Treated with LTP, both reagents reacted through a vapor phase ion/molecule reaction to generate the product. Finally, protonated reagents and products were identified by LTP-MS. Reaction products from imine formation reaction, Eschweiler-Clarke methylation and the Eberlin reaction were detected via reactive LTP-MS. Products from the imine formation reaction with reagents substituted with different functional groups (26 out of 28 trials) were successfully screened in a time of 30 s each. Besides, two short-lived reactive intermediates of Eschweiler-Clarke methylation were also detected. LTP in this study serves both as an ambient ionization source for analyte identification (including reagents, intermediates and products) and as a means to produce reagent ions to assist gas-phase ion/molecule reactions. The present reactive LTP-MS method enables fast screening for several analytes from several chemical reactions, which possesses good reagent compatibility and the potential to perform high-throughput analyte screening. In addition, with the detection of various reactive intermediates (intermediates I and II of Eschweiler-Clarke methylation), the present method would also contribute to revealing and elucidating reaction mechanisms. Copyright © 2015 John Wiley & Sons, Ltd.

  12. Radiated chemical reaction impacts on natural convective MHD mass transfer flow induced by a vertical cone

    Science.gov (United States)

    Sambath, P.; Pullepu, Bapuji; Hussain, T.; Ali Shehzad, Sabir

    2018-03-01

    The consequence of thermal radiation in laminar natural convective hydromagnetic flow of viscous incompressible fluid past a vertical cone with mass transfer under the influence of chemical reaction with heat source/sink is presented here. The surface of the cone is focused to a variable wall temperature (VWT) and wall concentration (VWC). The fluid considered here is a gray absorbing and emitting, but non-scattering medium. The boundary layer dimensionless equations governing the flow are solved by an implicit finite-difference scheme of Crank-Nicolson which has speedy convergence and stable. This method converts the dimensionless equations into a system of tri-diagonal equations and which are then solved by using well known Thomas algorithm. Numerical solutions are obtained for momentum, temperature, concentration, local and average shear stress, heat and mass transfer rates for various values of parameters Pr, Sc, λ, Δ, Rd are established with graphical representations. We observed that the liquid velocity decreased for higher values of Prandtl and Schmidt numbers. The temperature is boost up for decreasing values of Schimdt and Prandtl numbers. The enhancement in radiative parameter gives more heat to liquid due to which temperature is enhanced significantly.

  13. Document authentication at molecular levels using desorption atmospheric pressure chemical ionization mass spectrometry imaging.

    Science.gov (United States)

    Li, Ming; Jia, Bin; Ding, Liying; Hong, Feng; Ouyang, Yongzhong; Chen, Rui; Zhou, Shumin; Chen, Huanwen; Fang, Xiang

    2013-09-01

    Molecular images of documents were obtained by sequentially scanning the surface of the document using desorption atmospheric pressure chemical ionization mass spectrometry (DAPCI-MS), which was operated in either a gasless, solvent-free or methanol vapor-assisted mode. The decay process of the ink used for handwriting was monitored by following the signal intensities recorded by DAPCI-MS. Handwritings made using four types of inks on four kinds of paper surfaces were tested. By studying the dynamic decay of the inks, DAPCI-MS imaging differentiated a 10-min old from two 4 h old samples. Non-destructive forensic analysis of forged signatures either handwritten or computer-assisted was achieved according to the difference of the contour in DAPCI images, which was attributed to the strength personalized by different writers. Distinction of the order of writing/stamping on documents and detection of illegal printings were accomplished with a spatial resolution of about 140 µm. A Matlab® written program was developed to facilitate the visualization of the similarity between signature images obtained by DAPCI-MS. The experimental results show that DAPCI-MS imaging provides rich information at the molecular level and thus can be used for the reliable document analysis in forensic applications. © 2013 The Authors. Journal of Mass Spectrometry published by John Wiley & Sons, Ltd.

  14. Nonreductive chemical release of intact N-glycans for subsequent labeling and analysis by mass spectrometry.

    Science.gov (United States)

    Yuan, Jiangbei; Wang, Chengjian; Sun, Yujiao; Huang, Linjuan; Wang, Zhongfu

    2014-10-01

    A novel strategy is proposed, using cost-saving chemical reactions to generate intact free reducing N-glycans and their fluorescent derivatives from glycoproteins for subsequent analysis. N-Glycans without core α-1,3-linked fucose are released in reducing form by selective hydrolysis of the N-type carbohydrate-peptide bond of glycoproteins under a set of optimized mild alkaline conditions and are comparable to those released by commonly used peptide-N-glycosidase (PNGase) F in terms of yield without any detectable side reaction (peeling or deacetylation). The obtained reducing glycans can be routinely derivatized with 2-aminobenzoic acid (2-AA), 1-phenyl-3-methyl-5-pyrazolone (PMP), and potentially some other fluorescent reagents for comprehensive analysis. Alternatively, the core α-1,3-fucosylated N-glycans are released in mild alkaline medium and derivatized with PMP in situ, and their yields are comparable to those obtained using commonly used PNGase A without conspicuous peeling reaction or any detectable deacetylation. Using this new technique, the N-glycans of a series of purified glycoproteins and complex biological samples were successfully released and analyzed by electrospray ionization mass spectrometry (ESI-MS) and tandem mass spectrometry (MS/MS), demonstrating its general applicability to glycomic studies. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Flame Atmospheric Pressure Chemical Ionization Coupled with Negative Electrospray Ionization Mass Spectrometry for Ion Molecule Reactions.

    Science.gov (United States)

    Cheng, Sy-Chyi; Bhat, Suhail Muzaffar; Shiea, Jentaie

    2017-07-01

    Flame atmospheric pressure chemical ionization (FAPCI) combined with negative electrospray ionization (ESI) mass spectrometry was developed to detect the ion/molecule reactions (IMRs) products between nitric acid (HNO 3 ) and negatively charged amino acid, angiotensin I (AI) and angiotensin II (AII), and insulin ions. Nitrate and HNO 3 -nitrate ions were detected in the oxyacetylene flame, suggesting that a large quantity of nitric acid (HNO 3 ) was produced in the flame. The HNO 3 and negatively charged analyte ions produced by a negative ESI source were delivered into each arm of a Y-shaped stainless steel tube where they merged and reacted. The products were subsequently characterized with an ion trap mass analyzer attached to the exit of the Y-tube. HNO 3 showed the strongest affinity to histidine and formed (M histidine -H+HNO 3 ) - complex ions, whereas some amino acids did not react with HNO 3 at all. Reactions between HNO 3 and histidine residues in AI and AII resulted in the formation of dominant [M AI -H+(HNO 3 )] - and [M AII -H+(HNO 3 )] - ions. Results from analyses of AAs and insulin indicated that HNO 3 could not only react with basic amino acid residues, but also with disulfide bonds to form [M-3H+(HNO 3 ) n ] 3- complex ions. This approach is useful for obtaining information about the number of basic amino acid residues and disulfide bonds in peptides and proteins. Graphical Abstract ᅟ.

  16. Direct sampling of chemical weapons in water by photoionization mass spectrometry.

    Science.gov (United States)

    Syage, Jack A; Cai, Sheng-Suan; Li, Jianwei; Evans, Matthew D

    2006-05-01

    The vulnerability of water supplies to toxic contamination calls for fast and effective means for screening water samples for multiple threats. We describe the use of photoionization (PI) mass spectrometry (MS) for high-speed, high-throughput screening and molecular identification of chemical weapons (CW) threats and other hazardous compounds. The screening technology can detect a wide range of compounds at subacute concentrations with no sample preparation and a sampling cycle time of approximately 45 s. The technology was tested with CW agents VX, GA, GB, GD, GF, HD, HN1, and HN3, in addition to riot agents and precursors. All are sensitively detected and give simple PI mass spectra dominated by the parent ion. The target application of the PI MS method is as a routine, real-time early warning system for CW agents and other hazardous compounds in air and in water. In this work, we also present comprehensive measurements for water analysis and report on the system detection limits, linearity, quantitation accuracy, and false positive (FP) and false negative rates for concentrations at subacute levels. The latter data are presented in the form of receiver operating characteristic curves of the form of detection probability P(D) versus FP probability P(FP). These measurements were made using the CW surrogate compounds, DMMP, DEMP, DEEP, and DIMP. Method detection limits (3sigma) obtained using a capillary injection method yielded 1, 6, 3, and 2 ng/mL, respectively. These results were obtained using 1-microL injections of water samples without any preparation, corresponding to mass detection limits of 1, 6, 3, and 2 pg, respectively. The linear range was about 3-4 decades and the dynamic range about 4-5 decades. The relative standard deviations were generally <10% at CW subacute concentrations levels.

  17. Peter J Derrick and the Grand Scale 'Magnificent Mass Machine' mass spectrometer at Warwick.

    Science.gov (United States)

    Colburn, A W; Derrick, Peter J; Bowen, Richard D

    2017-12-01

    The value of the Grand Scale 'Magnificent Mass Machine' mass spectrometer in investigating the reactivity of ions in the gas phase is illustrated by a brief analysis of previously unpublished work on metastable ionised n-pentyl methyl ether, which loses predominantly methanol and an ethyl radical, with very minor contributions for elimination of ethane and water. Expulsion of an ethyl radical is interpreted in terms of isomerisation to ionised 3-pentyl methyl ether, via distonic ions and, possibly, an ion-neutral complex comprising ionised ethylcyclopropane and methanol. This explanation is consistent with the closely similar behaviour of the labelled analogues, C 3 H 7 CH 2 CD 2 OCH 3 +. and C 3 H 7 CD 2 CH 2 OCH 3 +. , and is supported by the greater kinetic energy release associated with loss of ethane from ionised n-propyl methyl ether compared to that starting from directly generated ionised 3-pentyl methyl ether.

  18. Mass production of chemicals from biomass-derived oil by directly atmospheric distillation coupled with co-pyrolysis

    Science.gov (United States)

    Zhang, Xue-Song; Yang, Guang-Xi; Jiang, Hong; Liu, Wu-Jun; Ding, Hong-Sheng

    2013-01-01

    Production of renewable commodity chemicals from bio-oil derived from fast pyrolysis of biomass has received considerable interests, but hindered by the presence of innumerable components in bio-oil. In present work, we proposed and experimentally demonstrated an innovative approach combining atmospheric distillation of bio-oil with co-pyrolysis for mass production of renewable chemicals from biomass, in which no waste was produced. It was estimated that 51.86 wt.% of distillate just containing dozens of separable organic components could be recovered using this approach. Ten protogenetic and three epigenetic compounds in distillate were qualitatively identified by gas chromatography/mass spectrometry and quantified by gas chromatography. Among them, the recovery efficiencies of acetic acid, propanoic acid, and furfural were all higher than 80 wt.%. Formation pathways of the distillate components in this process were explored. This work opens up a fascinating prospect for mass production of chemical feedstock from waste biomass. PMID:23350028

  19. Intracellular water exchange for measuring the dry mass, water mass and changes in chemical composition of living cells.

    Directory of Open Access Journals (Sweden)

    Francisco Feijó Delgado

    Full Text Available We present a method for direct non-optical quantification of dry mass, dry density and water mass of single living cells in suspension. Dry mass and dry density are obtained simultaneously by measuring a cell's buoyant mass sequentially in an H2O-based fluid and a D2O-based fluid. Rapid exchange of intracellular H2O for D2O renders the cell's water content neutrally buoyant in both measurements, and thus the paired measurements yield the mass and density of the cell's dry material alone. Utilizing this same property of rapid water exchange, we also demonstrate the quantification of intracellular water mass. In a population of E. coli, we paired these measurements to estimate the percent dry weight by mass and volume. We then focused on cellular dry density - the average density of all cellular biomolecules, weighted by their relative abundances. Given that densities vary across biomolecule types (RNA, DNA, protein, we investigated whether we could detect changes in biomolecular composition in bacteria, fungi, and mammalian cells. In E. coli, and S. cerevisiae, dry density increases from stationary to exponential phase, consistent with previously known increases in the RNA/protein ratio from up-regulated ribosome production. For mammalian cells, changes in growth conditions cause substantial shifts in dry density, suggesting concurrent changes in the protein, nucleic acid and lipid content of the cell.

  20. Intracellular Water Exchange for Measuring the Dry Mass, Water Mass and Changes in Chemical Composition of Living Cells

    Science.gov (United States)

    Hecht, Vivian C.; Son, Sungmin; Li, Yingzhong; Knudsen, Scott M.; Olcum, Selim; Higgins, John M.; Chen, Jianzhu; Grover, William H.; Manalis, Scott R.

    2013-01-01

    We present a method for direct non-optical quantification of dry mass, dry density and water mass of single living cells in suspension. Dry mass and dry density are obtained simultaneously by measuring a cell’s buoyant mass sequentially in an H2O-based fluid and a D2O-based fluid. Rapid exchange of intracellular H2O for D2O renders the cell’s water content neutrally buoyant in both measurements, and thus the paired measurements yield the mass and density of the cell’s dry material alone. Utilizing this same property of rapid water exchange, we also demonstrate the quantification of intracellular water mass. In a population of E. coli, we paired these measurements to estimate the percent dry weight by mass and volume. We then focused on cellular dry density – the average density of all cellular biomolecules, weighted by their relative abundances. Given that densities vary across biomolecule types (RNA, DNA, protein), we investigated whether we could detect changes in biomolecular composition in bacteria, fungi, and mammalian cells. In E. coli, and S. cerevisiae, dry density increases from stationary to exponential phase, consistent with previously known increases in the RNA/protein ratio from up-regulated ribosome production. For mammalian cells, changes in growth conditions cause substantial shifts in dry density, suggesting concurrent changes in the protein, nucleic acid and lipid content of the cell. PMID:23844039

  1. Synthetic diamond devices for radiotherapy applications: Thermoluminescent dosimeter and ionisation chamber

    International Nuclear Information System (INIS)

    Descamps, C.; Tromson, D.; Mer, C.; Nesladek, M.; Bergonzo, P.

    2006-01-01

    In radiotherapy field, the major usage of dosimeters is in the measurement of the dose received by the patient during radiotherapy (in-vivo measurements) and in beam calibration and uniformity checks. Diamond exhibits several interesting characteristics that make it a good candidate for radiation detection. It is indeed soft-tissue equivalent (Z=6 compared to Z=7.42 for human tissue), mechanically robust and relatively insensitive to radiation damage, chemically stable and non toxic. Moreover, the recent availability of synthetic samples, grown under controlled conditions using the chemical vapour deposition (C.V.D.) technique, allowed decreasing the high cost and the long delivery time of diamond devices. Diamond can be use for off-line dosimetry as thermoluminescent dosimeters or for on-line dosimetry as ionisation chamber [2,3]. These both applications are reported here. For this study, samples were grown in the laboratory and devices were then tested under X-ray irradiations and in clinical environment under medical cobalt source. The work described in this paper was performed in the framework of the European Integrated Project M.A.E.S.T.R.O., Methods and Advanced Equipment for Simulation and Treatment in Radio-Oncology, (6. FP) which is granted by the European Commission.The first results of this study clearly show that C.V.D. diamond detectors are suitable for dosimetry in radiotherapy applications. Moreover, for both T.L. dosimeters and ionisation chambers applications, and even though the sensitivity is subsequently reduced, nitrogen incorporation in films seems to significantly improve the dosimetric characteristics of the devices. Therefore, the optimisation of the material quality appears as a very important issue in order to increase the dosimetric characteristics of devices and more particularly, for use as thermoluminescent dosimeters, other impurities (Nickel, Phosphorus) will be tested. For ionisation chamber applications, experiments with

  2. Galactic chemical evolution with main-sequence mass loss and the distribution of F and G dwarfs

    International Nuclear Information System (INIS)

    Guzik, J.A.; Struck-Marcell, C.

    1988-01-01

    Simple closed galactic chemical-evolution models incorporating early main-sequence stellar mass loss have been developed for disk ages of 5, 10, and 15 Gyr. Relative to models without stellar mass loss, the models are shown to produce a 30-60 percent increase in the present mass ratio of dwarfs to dwarfs plus remnants, and a 200-250 percent increase in the total mass of late F dwarfs remaining on the main sequence at the current disk age. For present disk ages 5 and 10 Gyr, the total mass of mid-F dwarfs remaining on the main sequence is also shown to increase by 90-120 percent. It is concluded that models with main-sequence mass loss have a slightly reduced gas metallicity and slightly increased gas fraction midway through the evolution. 30 references

  3. Mass

    International Nuclear Information System (INIS)

    Quigg, Chris

    2007-01-01

    In the classical physics we inherited from Isaac Newton, mass does not arise, it simply is. The mass of a classical object is the sum of the masses of its parts. Albert Einstein showed that the mass of a body is a measure of its energy content, inviting us to consider the origins of mass. The protons we accelerate at Fermilab are prime examples of Einsteinian matter: nearly all of their mass arises from stored energy. Missing mass led to the discovery of the noble gases, and a new form of missing mass leads us to the notion of dark matter. Starting with a brief guided tour of the meanings of mass, the colloquium will explore the multiple origins of mass. We will see how far we have come toward understanding mass, and survey the issues that guide our research today.

  4. Standard test methods for chemical and mass spectrometric analysis of nuclear-grade gadolinium oxide (Gd2O3) powder

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 These test methods cover procedures for the chemical and mass spectrometric analysis of nuclear-grade gadolinium oxide powders to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Carbon by Direct CombustionThermal Conductivity C1408 Test Method for Carbon (Total) in Uranium Oxide Powders and Pellets By Direct Combustion-Infrared Detection Method Total Chlorine and Fluorine by Pyrohydrolysis Ion Selective Electrode C1502 Test Method for Determination of Total Chlorine and Fluorine in Uranium Dioxide and Gadolinium Oxide Loss of Weight on Ignition 7-13 Sulfur by CombustionIodometric Titration Impurity Elements by a Spark-Source Mass Spectrographic C761 Test Methods for Chemical, Mass Spectrometric, Spectrochemical,Nuclear, and Radiochemical Analysis of Uranium Hexafluoride C1287 Test Method for Determination of Impurities In Uranium Dioxide By Inductively Coupled Plasma Mass Spectrometry Gadolinium Content in Gadolinium Oxid...

  5. An integrated ion trap and time-of-flight mass spectrometer for chemical and photo- reaction dynamics studies.

    Science.gov (United States)

    Schowalter, Steven J; Chen, Kuang; Rellergert, Wade G; Sullivan, Scott T; Hudson, Eric R

    2012-04-01

    We demonstrate the integration of a linear quadrupole trap with a simple time-of-flight mass spectrometer with medium-mass resolution (m/Δm ∼ 50) geared towards the demands of atomic, molecular, and chemical physics experiments. By utilizing a novel radial ion extraction scheme from the linear quadrupole trap into the mass analyzer, a device with large trap capacity and high optical access is realized without sacrificing mass resolution. This provides the ability to address trapped ions with laser light and facilitates interactions with neutral background gases prior to analyzing the trapped ions. Here, we describe the construction and implementation of the device as well as present representative ToF spectra. We conclude by demonstrating the flexibility of the device with proof-of-principle experiments that include the observation of molecular-ion photodissociation and the measurement of trapped-ion chemical reaction rates. © 2012 American Institute of Physics

  6. An integrated ion trap and time-of-flight mass spectrometer for chemical and photo- reaction dynamics studies

    International Nuclear Information System (INIS)

    Schowalter, Steven J.; Chen Kuang; Rellergert, Wade G.; Sullivan, Scott T.; Hudson, Eric R.

    2012-01-01

    We demonstrate the integration of a linear quadrupole trap with a simple time-of-flight mass spectrometer with medium-mass resolution (m/Δm∼ 50) geared towards the demands of atomic, molecular, and chemical physics experiments. By utilizing a novel radial ion extraction scheme from the linear quadrupole trap into the mass analyzer, a device with large trap capacity and high optical access is realized without sacrificing mass resolution. This provides the ability to address trapped ions with laser light and facilitates interactions with neutral background gases prior to analyzing the trapped ions. Here, we describe the construction and implementation of the device as well as present representative ToF spectra. We conclude by demonstrating the flexibility of the device with proof-of-principle experiments that include the observation of molecular-ion photodissociation and the measurement of trapped-ion chemical reaction rates.

  7. Sensitivity of a Chemical Mass Balance model for PM2.5 to source profiles for differing styles of cooking

    Science.gov (United States)

    Abdullahi, K. L.; Delgado-Saborit, J. M.; Harrison, Roy M.

    2018-04-01

    Use of a Chemical Mass Balance model is one of the two most commonly used approaches to estimating atmospheric concentrations of cooking aerosol. Such models require the input of chemical profiles for each of the main sources contributing to particulate matter mass and there is appreciable evidence from the literature that not only the mass emission but also the chemical composition of particulate matter varies according to the food being prepared and the style of cooking. In this study, aerosol has been sampled in the laboratory from four different styles of cooking, i.e. Indian, Chinese, Western and African cooking. The chemical profiles of molecular markers have been quantified and are used individually within a Chemical Mass Balance model applied to air samples collected in a multi-ethnic area of Birmingham, UK. The model results give a source contribution estimate for cooking aerosol which is consistent with other comparable UK studies, but also shows a very low sensitivity of the model to the cooking aerosol profile utilised. A survey of local restaurants suggested a wide range of cooking styles taking place which may explain why no one profile gives an appreciably better fit in the CMB model.

  8. The universal relation of galactic chemical evolution: the origin of the mass-metallicity relation

    International Nuclear Information System (INIS)

    Zahid, H. Jabran; Dima, Gabriel I.; Kudritzki, Rolf-Peter; Kewley, Lisa J.; Geller, Margaret J.; Hwang, Ho Seong; Silverman, John D.; Kashino, Daichi

    2014-01-01

    We examine the mass-metallicity relation for z ≲ 1.6. The mass-metallicity relation follows a steep slope with a turnover, or 'knee', at stellar masses around 10 10 M ☉ . At stellar masses higher than the characteristic turnover mass, the mass-metallicity relation flattens as metallicities begin to saturate. We show that the redshift evolution of the mass-metallicity relation depends only on the evolution of the characteristic turnover mass. The relationship between metallicity and the stellar mass normalized to the characteristic turnover mass is independent of redshift. We find that the redshift-independent slope of the mass-metallicity relation is set by the slope of the relationship between gas mass and stellar mass. The turnover in the mass-metallicity relation occurs when the gas-phase oxygen abundance is high enough that the amount of oxygen locked up in low-mass stars is an appreciable fraction of the amount of oxygen produced by massive stars. The characteristic turnover mass is the stellar mass, where the stellar-to-gas mass ratio is unity. Numerical modeling suggests that the relationship between metallicity and the stellar-to-gas mass ratio is a redshift-independent, universal relationship followed by all galaxies as they evolve. The mass-metallicity relation originates from this more fundamental universal relationship between metallicity and the stellar-to-gas mass ratio. We test the validity of this universal metallicity relation in local galaxies where stellar mass, metallicity, and gas mass measurements are available. The data are consistent with a universal metallicity relation. We derive an equation for estimating the hydrogen gas mass from measurements of stellar mass and metallicity valid for z ≲ 1.6 and predict the cosmological evolution of galactic gas masses.

  9. Chemical analysis of bleach and hydroxide-based solutions after decontamination of the chemical warfare agent O-ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX).

    Science.gov (United States)

    Hopkins, F B; Gravett, M R; Self, A J; Wang, M; Chua, Hoe-Chee; Hoe-Chee, C; Lee, H S Nancy; Sim, N Lee Hoi; Jones, J T A; Timperley, C M; Riches, J R

    2014-08-01

    Detailed chemical analysis of solutions used to decontaminate chemical warfare agents can be used to support verification and forensic attribution. Decontamination solutions are amongst the most difficult matrices for chemical analysis because of their corrosive and potentially emulsion-based nature. Consequently, there are relatively few publications that report their detailed chemical analysis. This paper describes the application of modern analytical techniques to the analysis of decontamination solutions following decontamination of the chemical warfare agent O-ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX). We confirm the formation of N,N-diisopropylformamide and N,N-diisopropylamine following decontamination of VX with hypochlorite-based solution, whereas they were not detected in extracts of hydroxide-based decontamination solutions by nuclear magnetic resonance (NMR) spectroscopy or gas chromatography-mass spectrometry. We report the electron ionisation and chemical ionisation mass spectroscopic details, retention indices, and NMR spectra of N,N-diisopropylformamide and N,N-diisopropylamine, as well as analytical methods suitable for their analysis and identification in solvent extracts and decontamination residues.

  10. Beta-decay measurements of neutron-rich thallium, lead, and bismuth by means of resonant laser ionisation

    Science.gov (United States)

    Franchoo, S.; de Witte, H.; Andreyev, A. N.; Cederka¨Ll, J.; Dean, S.; de Smet, A.; Eeckhaudt, S.; Fedorov, D. V.; Fedosseev, V. N.; G´Rska, M.; Huber, G.; Huyse, M.; Janas, Z.; Ko¨Ster, U.; Kurcewicz, W.; Kurpeta, J.; Mayer, P.; Płchocki, A.; van de Vel, K.; van Duppen, P.; Weissman, L.; Isolde Collaboration

    2004-04-01

    Neutron-rich thallium, lead, and bismuth isotopes were investigated at the ISOLDE facility. After mass separation and resonant laser ionisation of the produced activity, new spectroscopic data were obtained for 215,218Bi and 215Pb. An attempt to reach heavy thallium had to be abandoned because of a strong francium component in the beam that gave rise to a neutron background through (α,n) reactions on the aluminium walls of the experimental chamber.

  11. Nitrogen losses from dairy manure estimated through nitrogen mass balance and chemical markers

    Science.gov (United States)

    Hristov, Alexander N.; Zaman, S.; Vander Pol, M.; Ndegwa, P.; Campbell, L.; Silva, S.

    2009-01-01

    Ammonia is an important air and water pollutant, but the spatial variation in its concentrations presents technical difficulties in accurate determination of ammonia emissions from animal feeding operations. The objectives of this study were to investigate the relationship between ammonia volatilization and ??15N of dairy manure and the feasibility of estimating ammonia losses from a dairy facility using chemical markers. In Exp. 1, the N/P ratio in manure decreased by 30% in 14 d as cumulative ammonia losses increased exponentially. Delta 15N of manure increased throughout the course of the experiment and ??15N of emitted ammonia increased (p < 0.001) quadratically from -31??? to -15 ???. The relationship between cumulative ammonia losses and ??15N of manure was highly significant (p < 0.001; r2 = 0.76). In Exp. 2, using a mass balance approach, approximately half of the N excreted by dairy cows (Bos taurus) could not be accounted for in 24 h. Using N/P and N/K ratios in fresh and 24-h manure, an estimated 0.55 and 0.34 (respectively) of the N excreted with feces and urine could not be accounted for. This study demonstrated that chemical markers (P, K) can be successfully used to estimate ammonia losses from cattle manure. The relationship between manure ??15N and cumulative ammonia loss may also be useful for estimating ammonia losses. Although promising, the latter approach needs to be further studied and verified in various experimental conditions and in the field. Copyright ?? 2009 by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America. All rights reserved.

  12. CHEMICAL EVOLUTION IN HIGH-MASS STAR-FORMING REGIONS: RESULTS FROM THE MALT90 SURVEY

    Energy Technology Data Exchange (ETDEWEB)

    Hoq, Sadia; Jackson, James M.; Foster, Jonathan B.; Sanhueza, Patricio; Claysmith, Christopher [Institute for Astrophysical Research, Boston University, Boston, MA 02215 (United States); Guzmán, Andrés [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138 (United States); Whitaker, J. Scott [Physics Department, Boston University, Boston, MA 02215 (United States); Rathborne, Jill M. [Australia Telescope National Facility, CSIRO Astronomy and Space Science, Epping, NSW (Australia); Vasyunina, Tatiana; Vasyunin, Anton, E-mail: shoq@bu.edu, E-mail: jackson@bu.edu, E-mail: patricio@bu.edu, E-mail: claysmit@bu.edu, E-mail: jonathan.b.foster@yale.edu, E-mail: aguzmanf@cfa.harvard.edu, E-mail: scott@bu.edu, E-mail: rathborne@csiro.au, E-mail: tv3h@virginia.edu, E-mail: aiv3f@virginia.edu [Department of Chemistry, University of Virginia, Charlottesville, VA 22904 (United States)

    2013-11-10

    The chemical changes of high-mass star-forming regions provide a potential method for classifying their evolutionary stages and, ultimately, ages. In this study, we search for correlations between molecular abundances and the evolutionary stages of dense molecular clumps associated with high-mass star formation. We use the molecular line maps from Year 1 of the Millimetre Astronomy Legacy Team 90 GHz (MALT90) Survey. The survey mapped several hundred individual star-forming clumps chosen from the ATLASGAL survey to span the complete range of evolution, from prestellar to protostellar to H II regions. The evolutionary stage of each clump is classified using the Spitzer GLIMPSE/MIPSGAL mid-IR surveys. Where possible, we determine the dust temperatures and H{sub 2} column densities for each clump from Herschel/Hi-GAL continuum data. From MALT90 data, we measure the integrated intensities of the N{sub 2}H{sup +}, HCO{sup +}, HCN and HNC (1-0) lines, and derive the column densities and abundances of N{sub 2}H{sup +} and HCO{sup +}. The Herschel dust temperatures increase as a function of the IR-based Spitzer evolutionary classification scheme, with the youngest clumps being the coldest, which gives confidence that this classification method provides a reliable way to assign evolutionary stages to clumps. Both N{sub 2}H{sup +} and HCO{sup +} abundances increase as a function of evolutionary stage, whereas the N{sub 2}H{sup +} (1-0) to HCO{sup +} (1-0) integrated intensity ratios show no discernable trend. The HCN (1-0) to HNC(1-0) integrated intensity ratios show marginal evidence of an increase as the clumps evolve.

  13. Chemical characterization of freshly emitted particulate matter from aircraft exhaust using single particle mass spectrometry

    Science.gov (United States)

    Abegglen, Manuel; Brem, B. T.; Ellenrieder, M.; Durdina, L.; Rindlisbacher, T.; Wang, J.; Lohmann, U.; Sierau, B.

    2016-06-01

    Non-volatile aircraft engine emissions are an important anthropogenic source of soot particles in the upper troposphere and in the vicinity of airports. They influence climate and contribute to global warming. In addition, they impact air quality and thus human health and the environment. The chemical composition of non-volatile particulate matter emission from aircraft engines was investigated using single particle time-of-flight mass spectrometry. The exhaust from three different aircraft engines was sampled and analyzed. The soot particulate matter was sampled directly behind the turbine in a test cell at Zurich Airport. Single particle analyses will focus on metallic compounds. The particles analyzed herein represent a subset of the emissions composed of the largest particles with a mobility diameter >100 nm due to instrumental restrictions. A vast majority of the analyzed particles was shown to contain elemental carbon, and depending on the engine and the applied thrust the elemental carbon to total carbon ratio ranged from 83% to 99%. The detected metallic compounds were all internally mixed with the soot particles. The most abundant metals in the exhaust were Cr, Fe, Mo, Na, Ca and Al; V, Ba, Co, Cu, Ni, Pb, Mg, Mn, Si, Ti and Zr were also detected. We further investigated potential sources of the ATOFMS-detected metallic compounds using Inductively Coupled Plasma Mass Spectrometry. The potential sources considered were kerosene, engine lubrication oil and abrasion from engine wearing components. An unambiguous source apportionment was not possible because most metallic compounds were detected in several of the analyzed sources.

  14. Analysis of Nitro-aromatic and Nitramine Explosives by Atmospheric Pressure Chemical Ionization / High Performance Liquid Chromatography / Mass Spectrometry / Mass Spectrometry

    International Nuclear Information System (INIS)

    Hicks, B.J.; Han, W.; Robben, J.R.

    2009-01-01

    This procedure is capable of separating and quantifying twenty-nine high explosives and internal surrogates with a single injection. After the initial preparation step, the sample is introduced to the high performance liquid chromatograph for target separation, ionized by atmospheric pressure chemical ionization and the explosives of interest are isolated / quantified by mass spectrometry / mass spectrometry. Concentrations of the target explosives are measured relative to the response of both internal and external standard concentrations. A C-18 reverse phase high performance liquid chromatograph column is used for separation. Ionization is performed using both positive and negative atmospheric pressure chemical ionization resulting in a molecular ion with little fragmentation. These ions are isolated at the first quadrupole of the mass spectrometer, dissociated by collision with argon in the collision cell and the resulting daughter ions are isolated at the second quadrupole. These daughter ions then reach the detector where they are quantified. To date this procedure represents the most thorough high performance liquid chromatography / mass spectrometry / mass spectrometry explosives analysis available in the environmental chemistry market. (authors)

  15. Quantitative correlations between collision induced dissociation mass spectrometry coupled with electrospray ionization or atmospheric pressure chemical ionization mass spectrometry - Experiment and theory

    Science.gov (United States)

    Ivanova, Bojidarka; Spiteller, Michael

    2018-04-01

    The problematic that we consider in this paper treats the quantitative correlation model equations between experimental kinetic and thermodynamic parameters of coupled electrospray ionization (ESI) mass spectrometry (MS) or atmospheric pressure chemical ionization (APCI) mass spectrometry with collision induced dissociation mass spectrometry, accounting for the fact that the physical phenomena and mechanisms of ESI- and APCI-ion formation are completely different. There are described forty two fragment reactions of three analytes under independent ESI- and APCI-measurements. The developed new quantitative models allow us to study correlatively the reaction kinetics and thermodynamics using the methods of mass spectrometry, which complementary application with the methods of the quantum chemistry provide 3D structural information of the analytes. Both static and dynamic quantum chemical computations are carried out. The object of analyses are [2,3-dimethyl-4-(4-methyl-benzoyl)-2,3-di-p-tolyl-cyclobutyl]-p-tolyl-methanone (1) and the polycyclic aromatic hydrocarbons derivatives of dibenzoperylen (2) and tetrabenzo [a,c,fg,op]naphthacene (3), respectively. As far as (1) is known to be a product of [2π+2π] cycloaddition reactions of chalcone (1,3-di-p-tolyl-propenone), however producing cyclic derivatives with different stereo selectivity, so that the study provide crucial data about the capability of mass spectrometry to provide determine the stereo selectivity of the analytes. This work also first provides quantitative treatment of the relations '3D molecular/electronic structures'-'quantum chemical diffusion coefficient'-'mass spectrometric diffusion coefficient', thus extending the capability of the mass spectrometry for determination of the exact 3D structure of the analytes using independent measurements and computations of the diffusion coefficients. The determination of the experimental diffusion parameters is carried out within the 'current monitoring method

  16. Nanoscale photoelectron ionisation detector based on lanthanum hexaboride

    International Nuclear Information System (INIS)

    Zimmer, C.M.; Kunze, U.; Schubert, J.; Hamann, S.; Doll, T.

    2011-01-01

    A nanoscale ioniser is presented exceeding the limitation of conventional photoionisation detectors. It employs accelerated photoelectrons that allow obtaining molecule specificity by the tuning of ionisation energies. The material lanthanum hexaboride (LaB 6 ) is used as air stable photo cathode. Thin films of that material deposited by pulsed laser deposition (PLD) show quantum efficiency (QE) in the range of 10 -5 which is comparable to laser photo stimulation results. A careful treatment of the material yields reasonable low work functions even after surface reoxidation which opens up the possibility of using ultraviolet light emitting diodes (UV LEDs) in replacement of discharge lamps. Schematic diagram of a photoelectron ionisation detector (PeID) operating by an electron emitter based on the photoelectric effect of lanthanum hexaboride. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  17. Threshold law for positron-atom impact ionisation

    International Nuclear Information System (INIS)

    Temkin, A.

    1982-01-01

    The threshold law for ionisation of atoms by positron impact is adduced in analogy with the author's approach to the electron-atom ionisation. It is concluded the Coulomb-dipole region of potential gives the essential part of the interaction in both cases and leads to the same kind of result: a modulated linear law. An additional process which enters positron ionisation is positronium formation in the continuum, but that will not dominate the threshold yield. The result is in sharp contrast to the positron threshold law as recently derived by Klar (J. Phys. B.; 14:4165 (1981)) on the basis of a Wannier-type (Phys. Rev.; 90:817 (1953)) analysis. (author)

  18. Ionisation Chambers for the LHC Beam Loss Detection

    CERN Document Server

    Gschwendtner, E; Dehning, B; Ferioli, G; Kain, V

    2003-01-01

    At the Large Hadron Collider (LHC) a beam loss system will be used to prevent and protect superconducting magnets against coil quenches and coil damages. Since the stored particle beam intensity is 8 orders of magnitude larger than the lowest quench level value particular attention is paid to the design of the secondary particle shower detectors. The foreseen ionisation chambers are optimised in geometry simulating the probable loss distribution along the magnets and convoluting the loss distribution with the secondary particle shower distributions. To reach the appropriate coverage of a particle loss and to determine the quench levels with a relative accuracy of 2 the number of the detectors and their lengths is weighted against the particle intensity density variation. In addition attention is paid to the electrical ionisation chamber signal to minimise the ion tail extension. This optimisation is based on time resolved test measurements in the PS booster. A proposal for a new ionisation chamber will be pre...

  19. Ionised gas kinematics in bipolar H II regions

    Science.gov (United States)

    Dalgleish, Hannah S.; Longmore, Steven N.; Peters, Thomas; Henshaw, Jonathan D.; Veitch-Michaelis, Joshua L.; Urquhart, James S.

    2018-05-01

    Stellar feedback plays a fundamental role in shaping the evolution of galaxies. Here we explore the use of ionised gas kinematics in young, bipolar H II regions as a probe of early feedback in these star-forming environments. We have undertaken a multi-wavelength study of a young, bipolar H II region in the Galactic disc, G316.81-0.06, which lies at the centre of a massive (˜103 M⊙) infrared-dark cloud filament. It is still accreting molecular gas as well as driving a ˜0.2 pc ionised gas outflow perpendicular to the filament. Intriguingly, we observe a large velocity gradient (47.81 ± 3.21 km s-1 pc-1) across the ionised gas in a direction perpendicular to the outflow. This kinematic signature of the ionised gas shows a reasonable correspondence with the simulations of young H II regions. Based on a qualitative comparison between our observations and these simulations, we put forward a possible explanation for the velocity gradients observed in G316.81-0.06. If the velocity gradient perpendicular to the outflow is caused by rotation of the ionised gas, then we infer that this rotation is a direct result of the initial net angular momentum in the natal molecular cloud. If this explanation is correct, this kinematic signature should be common in other young (bipolar) H II regions. We suggest that further quantitative analysis of the ionised gas kinematics of young H II regions, combined with additional simulations, should improve our understanding of feedback at these early stages.

  20. Microdosimetric constraints on specific adaptation mechanisms to reduce DNA damage caused by ionising radiation

    International Nuclear Information System (INIS)

    Burkart, W.; Heusser, P.; Vijayalaxmi

    1990-01-01

    The protective effect of pre-exposure of lymphocytes to ionising radiation indicates the presence of 'adaptive repair' in mammalian cells. Microdosimetric considerations, however, raise some doubts on the advantage of such a cellular mechanism for specifically reducing the radiation damage caused by environmental exposures. Contrary to most chemicals which endanger the integrity of the mammalian genome, the local dose and dose rate from ionising radiation at the cellular level remain quite high, even at lowest exposures. A single electron or alpha particle passing through a cell nucleus already yields nuclear doses of up to about 3 mGy and 400 mGy, respectively. Macroscopic doses below these nuclear doses from a single event will only reduce the fraction of cell nuclei encountering the passage of a particle but not the dose or dose rate in the affected volume. At environmental doses in the range of 1 to 5 mGy per annum, the time between two consecutive hits in a specific cell nucleus is in the range of months to years. Very low concentrations of bleomycin, a drug with high affinity to DNA, also triggers an adaptive response. This points to a more general stress response mechanism which may benefit the cell even at environmental levels of radioactivity, e.g. by protecting the integrity of DNA from attacks by chemicals, by endogenous radicals, by acids from anoxia, etc. (author)

  1. Development of chemical isotope labeling liquid chromatography mass spectrometry for silkworm hemolymph metabolomics

    International Nuclear Information System (INIS)

    Shen, Weifeng; Han, Wei; Li, Yunong; Meng, Zhiqi; Cai, Leiming; Li, Liang

    2016-01-01

    Silkworm (Bombyx mori) is a very useful target insect for evaluation of endocrine disruptor chemicals (EDCs) due to mature breeding techniques, complete endocrine system and broad basic knowledge on developmental biology. Comparative metabolomics of silkworms with and without EDC exposure offers another dimension of studying EDCs. In this work, we report a workflow on metabolomic profiling of silkworm hemolymph based on high-performance chemical isotope labeling (CIL) liquid chromatography mass spectrometry (LC-MS) and demonstrate its application in studying the metabolic changes associated with the pesticide dichlorodiphenyltrichloroethane (DDT) exposure in silkworm. Hemolymph samples were taken from mature silkworms after growing on diet that contained DDT at four different concentrations (1, 0.1, 0.01, 0.001 ppm) as well as on diet without DDT as controls. They were subjected to differential "1"2C-/"1"3C-dansyl labeling of the amine/phenol submetabolome, LC-UV quantification of the total amount of labeled metabolites for sample normalization, and LC-MS detection and relative quantification of individual metabolites in comparative samples. The total concentration of labeled metabolites did not show any significant change between four DDT-treatment groups and one control group. Multivariate statistical analysis of the metabolome data set showed that there was a distinct metabolomic separation between the five groups. Out of the 2044 detected peak pairs, 338 and 1471 metabolites have been putatively identified against the HMDB database and the EML library, respectively. 65 metabolites were identified by the dansyl library searching based on the accurate mass and retention time. Among the 65 identified metabolites, 33 positive metabolites had changes of greater than 1.20-fold or less than 0.83-fold in one or more groups with p-value of smaller than 0.05. Several useful biomarkers including serine, methionine, tryptophan, asymmetric dimethylarginine, N

  2. Development of chemical isotope labeling liquid chromatography mass spectrometry for silkworm hemolymph metabolomics

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Weifeng [Key Laboratory of Detection for Pesticide Residues, Ministry of Agriculture (China); Sericultural Research Institute, Zhejiang Academy of Agricultural Sciences, Hangzhou (China); Han, Wei; Li, Yunong [Department of Chemistry, University of Alberta, Edmonton, Alberta (Canada); Meng, Zhiqi [Sericultural Research Institute, Zhejiang Academy of Agricultural Sciences, Hangzhou (China); Cai, Leiming, E-mail: cailm@mail.zaas.ac.cn [Institute of Quality and Standard for Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou (China); Li, Liang, E-mail: Liang.Li@ualberta.ca [Department of Chemistry, University of Alberta, Edmonton, Alberta (Canada)

    2016-10-26

    Silkworm (Bombyx mori) is a very useful target insect for evaluation of endocrine disruptor chemicals (EDCs) due to mature breeding techniques, complete endocrine system and broad basic knowledge on developmental biology. Comparative metabolomics of silkworms with and without EDC exposure offers another dimension of studying EDCs. In this work, we report a workflow on metabolomic profiling of silkworm hemolymph based on high-performance chemical isotope labeling (CIL) liquid chromatography mass spectrometry (LC-MS) and demonstrate its application in studying the metabolic changes associated with the pesticide dichlorodiphenyltrichloroethane (DDT) exposure in silkworm. Hemolymph samples were taken from mature silkworms after growing on diet that contained DDT at four different concentrations (1, 0.1, 0.01, 0.001 ppm) as well as on diet without DDT as controls. They were subjected to differential {sup 12}C-/{sup 13}C-dansyl labeling of the amine/phenol submetabolome, LC-UV quantification of the total amount of labeled metabolites for sample normalization, and LC-MS detection and relative quantification of individual metabolites in comparative samples. The total concentration of labeled metabolites did not show any significant change between four DDT-treatment groups and one control group. Multivariate statistical analysis of the metabolome data set showed that there was a distinct metabolomic separation between the five groups. Out of the 2044 detected peak pairs, 338 and 1471 metabolites have been putatively identified against the HMDB database and the EML library, respectively. 65 metabolites were identified by the dansyl library searching based on the accurate mass and retention time. Among the 65 identified metabolites, 33 positive metabolites had changes of greater than 1.20-fold or less than 0.83-fold in one or more groups with p-value of smaller than 0.05. Several useful biomarkers including serine, methionine, tryptophan, asymmetric dimethylarginine, N

  3. Quantum coherence in photo-ionisation with tailored XUV pulses

    Science.gov (United States)

    Carlström, Stefanos; Mauritsson, Johan; Schafer, Kenneth J.; L'Huillier, Anne; Gisselbrecht, Mathieu

    2018-01-01

    Ionisation with ultrashort pulses in the extreme ultraviolet (XUV) regime can be used to prepare an ion in a superposition of spin-orbit substates. In this work, we study the coherence properties of such a superposition, created by ionising xenon atoms using two phase-locked XUV pulses at different frequencies. In general, if the duration of the driving pulse exceeds the quantum beat period, dephasing will occur. If however, the frequency difference of the two pulses matches the spin-orbit splitting, the coherence can be efficiently increased and dephasing does not occur.

  4. Detailed modeling of hydrodynamics mass transfer and chemical reactions in a bubble column using a discrete bubble model

    NARCIS (Netherlands)

    Darmana, D.; Deen, N.G.; Kuipers, J.A.M.

    2005-01-01

    A 3D discrete bubble model is adopted to investigate complex behavior involving hydrodynamics, mass transfer and chemical reactions in a gas¿liquid bubble column reactor. In this model a continuum description is adopted for the liquid phase and additionally each individual bubble is tracked in a

  5. Modeling of mass transfer and chemical reactions in a bubble column reactor using a discrete bubble model

    NARCIS (Netherlands)

    Darmana, D.; Deen, N.G.; Kuipers, J.A.M.

    2004-01-01

    A 3D discrete bubble model is adopted to investigate complex behavior involving hydrodynamics, mass transfer and chemical reactions in a gas-liquid bubble column reactor. In this model a continuum description is adopted for the liquid phase and additionally each individual bubble is tracked in a

  6. Detailed modeling of hydrodynamics mass transfer and chemical reactions in a bubble column using a discrete bubble model

    NARCIS (Netherlands)

    Darmana, D.; Deen, N.G.; Kuipers, J.A.M.

    2005-01-01

    A 3D discrete bubble model is adopted to investigate complex behavior involving hydrodynamics, mass transfer and chemical reactions in a gas–liquid bubble column reactor. In this model a continuum description is adopted for the liquid phase and additionally each individual bubble is tracked in a

  7. Regioisomers of octanoic acid-containing structured triacylglycerols analyzed by tandem mass spectrometry using ammonia negative ion chemical ionization

    DEFF Research Database (Denmark)

    Kurvinen, J.P.; Mu, Huiling; Kallio, H.

    2001-01-01

    Tandem mass spectrometry based on ammonia negative ion chemical ionization and sample introduction via direct exposure probe was applied to analysis of regioisomeric structures of octanoic acid containing structured triacylglycerols (TAG) of type MML, MLM, MLL, and LML (M, medium-chain fatty acid...

  8. Sensitive and comprehensive detection of chemical warfare agents in air by atmospheric pressure chemical ionization ion trap tandem mass spectrometry with counterflow introduction.

    Science.gov (United States)

    Seto, Yasuo; Sekiguchi, Hiroshi; Maruko, Hisashi; Yamashiro, Shigeharu; Sano, Yasuhiro; Takayama, Yasuo; Sekioka, Ryoji; Yamaguchi, Shintaro; Kishi, Shintaro; Satoh, Takafumi; Sekiguchi, Hiroyuki; Iura, Kazumitsu; Nagashima, Hisayuki; Nagoya, Tomoki; Tsuge, Kouichiro; Ohsawa, Isaac; Okumura, Akihiko; Takada, Yasuaki; Ezawa, Naoya; Watanabe, Susumu; Hashimoto, Hiroaki

    2014-05-06

    A highly sensitive and specific real-time field-deployable detection technology, based on counterflow air introduction atmospheric pressure chemical ionization, has been developed for a wide range of chemical warfare agents (CWAs) comprising gaseous (two blood agents, three choking agents), volatile (six nerve gases and one precursor agent, five blister agents), and nonvolatile (three lachrymators, three vomiting agents) agents in air. The approach can afford effective chemical ionization, in both positive and negative ion modes, for ion trap multiple-stage mass spectrometry (MS(n)). The volatile and nonvolatile CWAs tested provided characteristic ions, which were fragmented into MS(3) product ions in positive and negative ion modes. Portions of the fragment ions were assigned by laboratory hybrid mass spectrometry (MS) composed of linear ion trap and high-resolution mass spectrometers. Gaseous agents were detected by MS or MS(2) in negative ion mode. The limits of detection for a 1 s measurement were typically at or below the microgram per cubic meter level except for chloropicrin (submilligram per cubic meter). Matrix effects by gasoline vapor resulted in minimal false-positive signals for all the CWAs and some signal suppression in the case of mustard gas. The moisture level did influence the measurement of the CWAs.

  9. Analysis of chemical profiles of insect adhesion secretions by gas chromatography–mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Reitz, Manuela [Institute of Organic Chemistry, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen (Germany); Gerhardt, Heike [Institute of Pharmaceutical Sciences, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen (Germany); Schmitt, Christian; Betz, Oliver [Institute of Evolution and Ecology, University of Tübingen, Auf der Morgenstelle 28, 72076 Tübingen (Germany); Albert, Klaus, E-mail: klaus.albert@uni-tuebingen.de [Institute of Organic Chemistry, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen (Germany); Lämmerhofer, Michael, E-mail: michael.laemmerhofer@uni-tuebingen.de [Institute of Pharmaceutical Sciences, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen (Germany)

    2015-01-07

    Highlights: • Adhesion secretions of desert locust analyzed by GC–MS. • Insect secretions are composed of apolar and polar constituents. • Sampling simplified with contact SPME as compared to solvent sampling. • Thin-film SPME-GC–MS revealed complex alkane patterns for insect secretions. • Differences in tarsal (feet) secretions and samples from tibiae (upper legs) identified. - Abstract: This article reports on the chemical analysis of molecular profiles of tarsal secretions of the desert locust Schistocerca gregaria (Forsskål, 1775) by gas chromatography hyphenated with quadrupol mass spectrometry (GC–MS) as well as {sup 1}H-nuclear magnetic resonance ({sup 1}H NMR) spectroscopy. Special focus of this study was to elaborate on sampling methods which enable selective microscale extraction of insect secretions in a spatially controlled manner, in particular tarsal adhesive secretions and secretions located on cuticle surfaces at the tibia. Various solvent sampling procedures and contact solid-phase microextraction (SPME) methods were compared in terms of comprehensiveness and extraction efficiencies as measured by signal intensities in GC–MS. Solvent sampling with water as extraction solvent gave access to the elucidation of chemical profiles of polar compound classes such as amino acids and carbohydrates, but is extremely tedious. Contact SPME on the other hand can be regarded as a simplified and more elegant alternative, in particular for the lipophilic compound fraction. Many proteinogenic amino acids and ornithine as well as carbohydrate monomers arabinose, xylose, glucose, and galactose were detected in tarsal secretions after acid hydrolysis of aqueous extracts. Qualitatively similar but quantitatively significantly different molecular profiles were found for the lipid fraction which contained mainly n-alkanes and internally branched monomethyl-, dimethyl-, and trimethyl-alkanes in the C23–C49 range as well as long chain fatty acids and

  10. CHEMICAL COMPOSITION OF INTERMEDIATE-MASS STAR MEMBERS OF THE M6 (NGC 6405) OPEN CLUSTER

    Energy Technology Data Exchange (ETDEWEB)

    Kılıçoğlu, T.; Albayrak, B. [Ankara University, Faculty of Science, Department of Astronomy and Space Sciences, 06100, Tandoğan, Ankara (Turkey); Monier, R. [LESIA, UMR 8109, Observatoire de Paris Meudon, Place J. Janssen, Meudon (France); Richer, J. [Département de physique, Université de Montréal, 2900, Boulevard Edouard-Montpetit, Montréal QC, H3C 3J7 (Canada); Fossati, L., E-mail: tkilicoglu@ankara.edu.tr, E-mail: balbayrak@ankara.edu.tr, E-mail: Richard.Monier@obspm.fr, E-mail: Jacques.Richer@umontreal.ca, E-mail: lfossati@astro.uni-bonn.de [Argelander-Institut für Astronomie der Universität Bonn, Auf dem Hügel 71, D-53121, Bonn (Germany)

    2016-03-15

    We present here the first abundance analysis of 44 late B-, A-, and F-type members of the young open cluster M6 (NGC 6405, age about 75 Myr). Low- and medium-resolution spectra, covering the 4500–5840 Å wavelength range, were obtained using the FLAMES/GIRAFFE spectrograph attached to the ESO Very Large Telescopes. We determined the atmospheric parameters using calibrations of the Geneva photometry and by adjusting the H{sub β} profiles to synthetic ones. The abundances of up to 20 chemical elements, from helium to mercury, were derived for 19 late B, 16 A, and 9 F stars by iteratively adjusting synthetic spectra to the observations. We also derived a mean cluster metallicity of [Fe/H] = 0.07 ± 0.03 dex from the iron abundances of the F-type stars. We find that for most chemical elements, the normal late B- and A-type stars exhibit larger star-to-star abundance variations than the F-type stars probably because of the faster rotation of the B and A stars. The abundances of C, O, Mg, Si, and Sc appear to be anticorrelated with that of Fe, while the opposite holds for the abundances of Ca, Ti, Cr, Mn, Ni, Y, and Ba as expected if radiative diffusion is efficient in the envelopes of these stars. In the course of this analysis, we discovered five new peculiar stars: one mild Am, one Am, and one Fm star (HD 318091, CD-32 13109, GSC 07380-01211, CP1), one HgMn star (HD 318126, CP3), and one He-weak P-rich (HD 318101, CP4) star. We also discovered a new spectroscopic binary, most likely a SB2. We performed a detailed modeling of HD 318101, the new He-weak P-rich CP star, using the Montréal stellar evolution code XEVOL which self-consistently treats all particle transport processes. Although the overall abundance pattern of this star is properly reproduced, we find that detailed abundances (in particular the high P excess) resisted modeling attempts even when a range of turbulence profiles and mass-loss rates were considered. Solutions are proposed which are

  11. Analysis of chemical profiles of insect adhesion secretions by gas chromatography–mass spectrometry

    International Nuclear Information System (INIS)

    Reitz, Manuela; Gerhardt, Heike; Schmitt, Christian; Betz, Oliver; Albert, Klaus; Lämmerhofer, Michael

    2015-01-01

    Highlights: • Adhesion secretions of desert locust analyzed by GC–MS. • Insect secretions are composed of apolar and polar constituents. • Sampling simplified with contact SPME as compared to solvent sampling. • Thin-film SPME-GC–MS revealed complex alkane patterns for insect secretions. • Differences in tarsal (feet) secretions and samples from tibiae (upper legs) identified. - Abstract: This article reports on the chemical analysis of molecular profiles of tarsal secretions of the desert locust Schistocerca gregaria (Forsskål, 1775) by gas chromatography hyphenated with quadrupol mass spectrometry (GC–MS) as well as 1 H-nuclear magnetic resonance ( 1 H NMR) spectroscopy. Special focus of this study was to elaborate on sampling methods which enable selective microscale extraction of insect secretions in a spatially controlled manner, in particular tarsal adhesive secretions and secretions located on cuticle surfaces at the tibia. Various solvent sampling procedures and contact solid-phase microextraction (SPME) methods were compared in terms of comprehensiveness and extraction efficiencies as measured by signal intensities in GC–MS. Solvent sampling with water as extraction solvent gave access to the elucidation of chemical profiles of polar compound classes such as amino acids and carbohydrates, but is extremely tedious. Contact SPME on the other hand can be regarded as a simplified and more elegant alternative, in particular for the lipophilic compound fraction. Many proteinogenic amino acids and ornithine as well as carbohydrate monomers arabinose, xylose, glucose, and galactose were detected in tarsal secretions after acid hydrolysis of aqueous extracts. Qualitatively similar but quantitatively significantly different molecular profiles were found for the lipid fraction which contained mainly n-alkanes and internally branched monomethyl-, dimethyl-, and trimethyl-alkanes in the C23–C49 range as well as long chain fatty acids and aldehydes

  12. Airborne observations of formic acid using a chemical ionization mass spectrometer

    Directory of Open Access Journals (Sweden)

    M. Le Breton

    2012-12-01

    Full Text Available The first airborne measurements of formic acid mixing ratios over the United Kingdom were measured on the FAAM BAe-146 research aircraft on 16 March 2010 with a chemical ionization mass spectrometer using I reagent ions. The I ionization scheme was able to measure formic acid mixing ratios at 1 Hz in the boundary layer.

    In-flight standard addition calibrations from a formic acid source were used to determine the instrument sensitivity of 35 ± 6 ion counts pptv−1 s−1 and a limit of detection of 25 pptv. Routine measurements were made through a scrubbed inlet to determine the instrumental background. Three plumes of formic acid were observed over the UK, originating from London, Humberside and Tyneside. The London plume had the highest formic acid mixing ratio throughout the flight, peaking at 358 pptv. No significant correlations of formic acid with NOx and ozone were found, but a positive correlation was observed between CO and HCOOH within the two plumes where coincident data were recorded.

    A trajectory model was employed to determine the sources of the plumes and compare modelled mixing ratios with measured values. The model underestimated formic acid concentrations by up to a factor of 2. This is explained by missing sources in the model, which were considered to be both primary emissions of formic acid of mainly anthropogenic origin and a lack of precursor emissions, such as isoprene, from biogenic sources, whose oxidation in situ would lead to formic acid formation.

  13. The case against protecting the environment from ionising radiation

    International Nuclear Information System (INIS)

    Smith, J.T.

    2004-01-01

    The objective of this paper is to present the (rarely heard) argument in favour of retention of the present system of radiation protection of the environment. There has been a recent trend in the radioecological and radiation protection community towards greater regulation of the effects of ionising radiations on biota. In particular, the often quoted International Commission on Radiation Protection (ICRP) hypothesis that: If humans are protected from the effects of ionising radiation, then flora and fauna are also adequately protected has been criticised as being too anthropocentric and not adequate for protection of the environment. In this paper I will challenge this view, arguing firstly that this statement is almost always quoted out of its proper context, and secondly that the ICRP hypothesis does adequately protect the environment from the effects of ionising radiations. In view of the relatively insignificant effect of regulated releases of ionising radiation on the environment, the economic cost of further regulation will not result in a significant environmental benefit. Whilst empirical research to test the ICRP hypothesis should continue, until there is clear evidence against it, this simple and cost-effective approach should be retained. This would benefit the environment by directing scarce resources to more urgent environmental problems. (author)

  14. Cost considerations for an ionising energy treatment facility

    International Nuclear Information System (INIS)

    Culpitt, R.A.

    1985-01-01

    Variables influencing the cost of food irradiation can be included under three broad headings: the physical characteristics of products to be treated; the operational characteristics of the plant to be used; costs of establishment and operation of an ionising energy treatment

  15. NDT using ionising radiation in the Indian space programme

    International Nuclear Information System (INIS)

    Viswanathan, K.

    1997-01-01

    Ionising radiations continue to play a vital role in the Non-Destructive Evaluation (NDE) of various components used in space vehicles and satellites. The different Non-Destructive Testing (NDT) methods which are useful to the Indian space programme are discussed. 4 refs., 5 figs

  16. Effects of heat and mass transfer on unsteady boundary layer flow of a chemical reacting Casson fluid

    Science.gov (United States)

    Khan, Kashif Ali; Butt, Asma Rashid; Raza, Nauman

    2018-03-01

    In this study, an endeavor is to observe the unsteady two-dimensional boundary layer flow with heat and mass transfer behavior of Casson fluid past a stretching sheet in presence of wall mass transfer by ignoring the effects of viscous dissipation. Chemical reaction of linear order is also invoked here. Similarity transformation have been applied to reduce the governing equations of momentum, energy and mass into non-linear ordinary differential equations; then Homotopy analysis method (HAM) is applied to solve these equations. Numerical work is done carefully with a well-known software MATHEMATICA for the examination of non-dimensional velocity, temperature, and concentration profiles, and then results are presented graphically. The skin friction (viscous drag), local Nusselt number (rate of heat transfer) and Sherwood number (rate of mass transfer) are discussed and presented in tabular form for several factors which are monitoring the flow model.

  17. Analysis of human plasma metabolites across different liquid chromatography/mass spectrometry platforms: Cross-platform transferable chemical signatures.

    Science.gov (United States)

    Telu, Kelly H; Yan, Xinjian; Wallace, William E; Stein, Stephen E; Simón-Manso, Yamil

    2016-03-15

    The metabolite profiling of a NIST plasma Standard Reference Material (SRM 1950) on different liquid chromatography/mass spectrometry (LC/MS) platforms showed significant differences. Although these findings suggest caution when interpreting metabolomics results, the degree of overlap of both profiles allowed us to use tandem mass spectral libraries of recurrent spectra to evaluate to what extent these results are transferable across platforms and to develop cross-platform chemical signatures. Non-targeted global metabolite profiles of SRM 1950 were obtained on different LC/MS platforms using reversed-phase chromatography and different chromatographic scales (conventional HPLC, UHPLC and nanoLC). The data processing and the metabolite differential analysis were carried out using publically available (XCMS), proprietary (Mass Profiler Professional) and in-house software (NIST pipeline). Repeatability and intermediate precision showed that the non-targeted SRM 1950 profiling was highly reproducible when working on the same platform (relative standard deviation (RSD) HPLC, UHPLC and nanoLC) on the same platform. A substantial degree of overlap (common molecular features) was also found. A procedure to generate consistent chemical signatures using tandem mass spectral libraries of recurrent spectra is proposed. Different platforms rendered significantly different metabolite profiles, but the results were highly reproducible when working within one platform. Tandem mass spectral libraries of recurrent spectra are proposed to evaluate the degree of transferability of chemical signatures generated on different platforms. Chemical signatures based on our procedure are most likely cross-platform transferable. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.

  18. Water masses in the Humboldt Current System: Properties, distribution, and the nitrate deficit as a chemical water mass tracer for Equatorial Subsurface Water off Chile

    Science.gov (United States)

    Silva, Nelson; Rojas, Nora; Fedele, Aldo

    2009-07-01

    Three sections are used to analyze the physical and chemical characteristics of the water masses in the eastern South Pacific and their distributions. Oceanographic data were taken from the SCORPIO (May-June 1967), PIQUERO (May-June 1969), and KRILL (June 1974) cruises. Vertical sections of temperature, salinity, σ θ, dissolved oxygen, nitrate, nitrite, phosphate, and silicate were used to analyze the water column structure. Five water masses were identified in the zone through T- S diagrams: Subantarctic Water, Subtropical Water, Equatorial Subsurface Water, Antarctic Intermediate Water, and Pacific Deep Water. Their proportions in the sea water mixture are calculated using the mixing triangle method. Vertical sections were used to describe the geographical distributions of the water mass cores in the upper 1500 m. Several characteristic oceanographic features in the study area were analyzed: the shallow salinity minimum displacement towards the equator, the equatorial subsurface salinity maximum associated with a dissolved oxygen minimum zone and a high nutrient content displacement towards the south, and the equatorward intermediate Antarctic salinity minimum associated with a dissolved oxygen maximum. The nitrate deficit generated in the denitrification area off Peru and northern Chile is proposed as a conservative chemical tracer for the Equatorial Subsurface Waters off the coast of Chile, south of 25°S.

  19. Studies of the electron-impact double-ionisation process in magnesium using coincidence techniques

    International Nuclear Information System (INIS)

    Ford, M.J.

    1998-01-01

    This article will review recent measurements of the electron-impact double-ionisation of atomic magnesium. Results for the resonant Auger double-ionisation process with coincident detection of all three outgoing electrons, the (e, 3e) experiment, and for the direct double-ionisation process where only two outgoing electrons are detected, the (e, (3 -1)e) experiment, will be discussed. The results are analysed with reference to ionisation mechanisms and comparisons are made with calculated double-ionisation cross sections. Copyright (1998) CSIRO Australia

  20. Mass Spectrometric Determination of Chemical Warfare Agents in Indoor Sample Media Typically Collected During Forensic Investigations

    National Research Council Canada - National Science Library

    D'Agostino, P. A; Hancock, J. R; Chenier, C. L

    2005-01-01

    .... DRDC Suffield, in collaboration with the Royal Canadian Mounted Police, identified a need for analytical methods for chemical warfare agent identification in media, including flooring, wall surfaces...

  1. Tyrosine residues modification studied by MALDI-TOF mass spectrometry

    International Nuclear Information System (INIS)

    Santrucek, Jiri; Strohalm, Martin; Kadlcik, Vojtech; Hynek, Radovan; Kodicek, Milan

    2004-01-01

    Amino acid residue-specific reactivity in proteins is of great current interest in structural biology as it provides information about solvent accessibility and reactivity of the residue and, consequently, about protein structure and possible interactions. In the work presented tyrosine residues of three model proteins with known spatial structure are modified with two tyrosine-specific reagents: tetranitromethane and iodine. Modified proteins were specifically digested by proteases and the mass of resulting peptide fragments was determined using matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry. Our results show that there are only small differences in the extent of tyrosine residues modification by tetranitromethane and iodine. However, data dealing with accessibility of reactive residues obtained by chemical modifications are not completely identical with those obtained by nuclear magnetic resonance and X-ray crystallography. These interesting discrepancies can be caused by local molecular dynamics and/or by specific chemical structure of the residues surrounding

  2. Spatially resolved chemical analysis of cicada wings using laser-ablation electrospray ionization (LAESI) imaging mass spectrometry (IMS).

    Science.gov (United States)

    Román, Jessica K; Walsh, Callee M; Oh, Junho; Dana, Catherine E; Hong, Sungmin; Jo, Kyoo D; Alleyne, Marianne; Miljkovic, Nenad; Cropek, Donald M

    2018-03-01

    Laser-ablation electrospray ionization (LAESI) imaging mass spectrometry (IMS) is an emerging bioanalytical tool for direct imaging and analysis of biological tissues. Performing ionization in an ambient environment, this technique requires little sample preparation and no additional matrix, and can be performed on natural, uneven surfaces. When combined with optical microscopy, the investigation of biological samples by LAESI allows for spatially resolved compositional analysis. We demonstrate here the applicability of LAESI-IMS for the chemical analysis of thin, desiccated biological samples, specifically Neotibicen pruinosus cicada wings. Positive-ion LAESI-IMS accurate ion-map data was acquired from several wing cells and superimposed onto optical images allowing for compositional comparisons across areas of the wing. Various putative chemical identifications were made indicating the presence of hydrocarbons, lipids/esters, amines/amides, and sulfonated/phosphorylated compounds. With the spatial resolution capability, surprising chemical distribution patterns were observed across the cicada wing, which may assist in correlating trends in surface properties with chemical distribution. Observed ions were either (1) equally dispersed across the wing, (2) more concentrated closer to the body of the insect (proximal end), or (3) more concentrated toward the tip of the wing (distal end). These findings demonstrate LAESI-IMS as a tool for the acquisition of spatially resolved chemical information from fragile, dried insect wings. This LAESI-IMS technique has important implications for the study of functional biomaterials, where understanding the correlation between chemical composition, physical structure, and biological function is critical. Graphical abstract Positive-ion laser-ablation electrospray ionization mass spectrometry coupled with optical imaging provides a powerful tool for the spatially resolved chemical analysis of cicada wings.

  3. Characterization of aerosol chemical composition with aerosol mass spectrometry in Central Europe: an overview

    Directory of Open Access Journals (Sweden)

    V. A. Lanz

    2010-11-01

    Full Text Available Real-time measurements of non-refractory submicron aerosols (NR-PM1 were conducted within the greater Alpine region (Switzerland, Germany, Austria, France and Liechtenstein during several week-long field campaigns in 2002–2009. This region represents one of the most important economic and recreational spaces in Europe. A large variety of sites was covered including urban backgrounds, motorways, rural, remote, and high-alpine stations, and also mobile on-road measurements were performed. Inorganic and organic aerosol (OA fractions were determined by means of aerosol mass spectrometry (AMS. The data originating from 13 different field campaigns and the combined data have been utilized for providing an improved temporal and spatial data coverage.

    The average mass concentration of NR-PM1 for the different campaigns typically ranged between 10 and 30 μg m−3. Overall, the organic portion was most abundant, ranging from 36% to 81% of NR-PM1. Other main constituents comprised ammonium (5–15%, nitrate (8–36%, sulfate (3–26%, and chloride (0–5%. These latter anions were, on average, fully neutralized by ammonium. As a major result, time of the year (winter vs. summer and location of the site (Alpine valleys vs. Plateau could largely explain the variability in aerosol chemical composition for the different campaigns and were found to be better descriptors for aerosol composition than the type of site (urban, rural etc.. Thus, a reassessment of classifications of measurements sites might be considered in the future, possibly also for other regions of the world.

    The OA data was further analyzed using positive matrix factorization (PMF and the multi-linear engine ME (factor analysis separating the total OA into its underlying components, such as oxygenated (mostly secondary organic aerosol (OOA, hydrocarbon-like and freshly emitted organic aerosol (HOA, as well as OA from biomass

  4. Assessing the regional impact of indonesian biomass burning emissions based on organic molecular tracers and chemical mass balance modeling

    Science.gov (United States)

    Engling, G.; He, J.; Betha, R.; Balasubramanian, R.

    2014-08-01

    Biomass burning activities commonly occur in Southeast Asia (SEA), and are particularly intense in Indonesia during the dry seasons. The effect of biomass smoke emissions on air quality in the city state of Singapore was investigated during a haze episode in October 2006. Substantially increased levels of airborne particulate matter (PM) and associated chemical species were observed during the haze period. Specifically, the enhancement in the concentration of molecular tracers for biomass combustion such as levoglucosan by as much as two orders of magnitude and the diagnostic ratios of individual organic compounds indicated that biomass burning emissions caused a regional smoke haze episode due to their long-range transport by prevailing winds. With the aid of air mass backward trajectories and chemical mass balance modeling, large-scale forest and peat fires in Sumatra and Kalimantan were identified as the sources of the smoke aerosol, exerting a significant impact on air quality in downwind areas, such as Singapore.

  5. A High Throughput Ambient Mass Spectrometric Approach to Species Identification and Classification from Chemical Fingerprint Signatures

    OpenAIRE

    Musah, Rabi A.; Espinoza, Edgard O.; Cody, Robert B.; Lesiak, Ashton D.; Christensen, Earl D.; Moore, Hannah E.; Maleknia, Simin; Drijfhout, Falko P.

    2015-01-01

    A high throughput method for species identification and classification through chemometric processing of direct analysis in real time (DART) mass spectrometry-derived fingerprint signatures has been developed. The method entails introduction of samples to the open air space between the DART ion source and the mass spectrometer inlet, with the entire observed mass spectral fingerprint subjected to unsupervised hierarchical clustering processing. A range of both polar and non-polar chemotypes a...

  6. Ion source for a mass spectrometer

    International Nuclear Information System (INIS)

    Kappus, G.

    1980-01-01

    The ion source is used for electron impact ionisation and chemical ionisation of a gaseous or vapour test substance. In this type of operation, openings of different sizes are provided for the entry of electrons, the exit of ions and sample entry, because of different working pressures. Part of the source is made as a movable case or container floor with the ion exit opening being a shutter. (DG) [de

  7. The influence of Oort clouds on the mass and chemical balance of the interstellar medium

    International Nuclear Information System (INIS)

    Stern, S.A.; Shull, J.M.

    1990-01-01

    The contribution of stellar encounters and interstellar erosion to comet cloud mass injection to the ISM is calculated. It is shown that evaporative mass loss from passing stars and SNe results in an average Galactic mass injection rate of up to 10 to the -5th solar mass/yr if such clouds are frequent around solar-type stars. Cometary erosion by interstellar grains produces an injection rate of 10 to the -5th to 10 to the -4th solar mass/yr. An injection rate of 2 x 10 to the -5th solar mass/yr is calculated. Each of these rates could be increased by a factor of about 15 if the comet clouds contain a significant amount of smaller debris. It is concluded that the total mass injection rate of material to the ISM by comet clouds is small compared to other ISM mass injection sources. Comet cloud mass loss to the ISM could be responsible for a sizeable fraction of the metal and dust abundances of the ISM if Oort clouds are common. 50 refs

  8. Chemical residues in Dolphins from the US Atlantic coast including atlantic bottlenose obtained during the 1987/88 mass mortality

    Energy Technology Data Exchange (ETDEWEB)

    Kuehl, D.W.; Haebler, R.; Potter, C.

    1991-01-01

    Bottlenose dolphins (Tursiops truncatus) collected during the 1987/88 mass mortality event along the Atlantic coast of the United States have been analyzed for anthropogenic chemical contaminants. Average contaminant concentrations in adult males were higher than the average concentrations measured in adult females. Females could be divided into two groups by contaminant concentrations, one with low concentrations, and another with concentrations 4.4 times (PCBs) to 8.9 times (p,p'-DDE) greater. Contaminant concentrations in bottlenose were generally greater than the concentrations measured in either common (Delphinus delphis) or white-sided (Lagernorhynchus acutus) dolphins from the western North Atlantic Ocean. A subset of animals screened for unusual chemical contaminants showed that numerous polybrominated chemicals were present, including polybrominated biphenyls and diphenyl ethers not previously found in marine mammals from U.S. coastal waters.

  9. Using matrix peaks to map topography: Increased mass resolution and enhanced sensitivity in chemical imaging

    NARCIS (Netherlands)

    McDonnell, Liam A.; Mize, Todd H.; Luxembourg, Stefan L.; Koster, Sander; Eijkel, Gert B.; Verpoorte, Elisabeth; De Rooij, Nico F.; Heeren, Ron M. A.

    2003-01-01

    It is well known in secondary ion mass spectrometry (SIMS) that sample topography leads to decreased mass resolution. Specifically, the ion's time of flight is dependent on where it was generated. Here, using matrix-enhanced SIMS, it is demonstrated that, in addition to increasing the yield of

  10. Standard test methods for chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade plutonium dioxide powders and pellets

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 These test methods cover procedures for the chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade plutonium dioxide powders and pellets to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Plutonium Sample Handling 8 to 10 Plutonium by Controlled-Potential Coulometry Plutonium by Ceric Sulfate Titration Plutonium by Amperometric Titration with Iron(II) Plutonium by Diode Array Spectrophotometry Nitrogen by Distillation Spectrophotometry Using Nessler Reagent 11 to 18 Carbon (Total) by Direct Combustion–Thermal Conductivity 19 to 30 Total Chlorine and Fluorine by Pyrohydrolysis 31 to 38 Sulfur by Distillation Spectrophotometry 39 to 47 Plutonium Isotopic Analysis by Mass Spectrometry Rare Earth Elements by Spectroscopy 48 to 55 Trace Elements by Carrier–Distillation Spectroscopy 56 to 63 Impurities by ICP-AES Impurity Elements by Spark-Source Mass Spectrography 64 to 70 Moisture by the Coulomet...

  11. Quantifying the effect of medium composition on the diffusive mass transfer of hydrophobic organic chemicals through unstirred boundary layers

    DEFF Research Database (Denmark)

    Mayer, Philipp; Karlson, U.; Christensen, P.S.

    2005-01-01

    Unstirred boundary layers (UBLs) often act as a bottleneck for the diffusive transport of hydrophobic organic compounds (HOCs) in the environment. Therefore, a microscale technique was developed for quantifying mass transfer through a 100-μm thin UBL, with the medium composition of the UBL...... as the controllable factor. The model compound fluoranthene had to (1) partition from a contaminated silicone disk (source) into the medium, (2) then diffuse through 100 μm of medium (UBL), and finally (3) partition into a clean silicone layer (sink). The diffusive mass transfer from source to sink was monitored over...... of magnitude. These results demonstrate that medium constituents, which normally are believed to bind hydrophobic organic chemicals, actually can enhance the diffusive mass transfer of HOCs in the vicinity of a diffusion source (e.g., contaminated soil particles). The technique can be used to evaluate...

  12. Mass Transfer and Chemical Reaction Approach of the Kinetics of the Acetylation of Gadung Flour using Glacial Acetic Acid

    Directory of Open Access Journals (Sweden)

    Andri Cahyo Kumoro

    2015-03-01

    Full Text Available Acetylation is one of the common methods of modifying starch properties by introducing acetil (CH3CO groups to starch molecules at low temperatures. While most acetylation is conducted using starch as anhidroglucose source and acetic anhydride or vinyl acetate as nucleophilic agents, this work employ reactants, namely flour and glacial acetic acid. The purpose of this work are to study the effect of pH reaction and GAA/GF mass ratio on the rate of acetylation reaction and to determine its rate constants. The acetylation of gadung flour with glacial acetic acid in the presence of sodium hydroxide as a homogenous catalyst was studied at ambient temperature with pH ranging from 8-10 and different mass ratio of acetic acid : gadung flour (1:3; 1:4; and 1:5. It was found that increasing pH, lead to increase the degree of substitution, while increasing GAA/GF mass ratio caused such decreases in the degree of substitution, due to the hydrolysis of the acetylated starch. The desired starch acetylation reaction is accompanied by undesirable hydrolysis reaction of the acetylated starch after 40-50 minutes reaction time. Investigation of kinetics of the reaction observed that the value of mass transfer rate constant (Kcs is smaller than the surface reaction rate constant (k. Thus, it can be concluded that rate controlling step is mass transfer.  © 2015 BCREC UNDIP. All rights reservedReceived: 7th August 2014; Revised: 8th September 2014; Accepted: 14th September 2014How to Cite: Kumoro, A.C., Amelia, R. (2015. Mass Transfer and Chemical Reaction Approach of the Kinetics of the Acetylation of Gadung Flour using Glacial Acetic Acid. Bulletin of Chemical Reaction Engineering & Catalysis, 10 (1: 30-37. (doi:10.9767/bcrec.10.1.7181.30-37Permalink/DOI: http://dx.doi.org/10.9767/bcrec.10.1.7181.30-37

  13. Chemical Safety Alert: First Responders’ Environmental Liability Due To Mass Decontamination Runoff

    Science.gov (United States)

    CERCLA's good Samaritan provisions protect responders such as the Chemical Weapons Improved Response Team during lifesaving actions. Once imminent threats are addressed, responders should contain contamination and avoid/mitigate environmental consequences.

  14. Measured Mass-Normalized Optical Cross Sections For Aerosolized Organophosphorus Chemical Warfare Simulants

    National Research Council Canada - National Science Library

    Gurton, Kristan P; Felton, Melvin; Dahmani, Rachid; Ligon, David

    2007-01-01

    We present newly measured results of an ongoing experimental program established to measure optical cross sections in the mid and long wave infrared for a variety of chemical and biologically based aerosols...

  15. Chemical reaction in MHD flow past a vertical plate with mass ...

    African Journals Online (AJOL)

    flow in a vertical double passage channel using Robin boundary conditions. ... the diffusion of a chemically reactive species in a laminar boundary layer flow. ...... hydrodynamic flow past a flat plate will Hall effects, Journal of the Physical.

  16. Spatial localisation of curcumin and rapid screening of the chemical compositions of turmeric rhizomes (Curcuma longa Linn.) using Direct Analysis in Real Time-Mass Spectrometry (DART-MS).

    Science.gov (United States)

    Rahman, A F M Motiur; Angawi, Rihab F; Kadi, Adnan A

    2015-04-15

    Curcumin is a potent antioxidant agent having versatile biological activities is present in turmeric rhizomes (Curcuma longa Linn.). Powder of turmeric rhizomes is consumes as curry spicy worldwide, especially in Asia. In this study, we demonstrate that, bioactive curcumin and its analog demethoxycurcumin are chiefly concentrated in the pith rather than the other parts of the turmeric rhizomes and it was discovered using modern atmospheric ionisation source 'Direct Analysis in Real Time' (DART) connected with an Ion Trap Mass Spectrometry. In addition, all the major components present in turmeric rhizomes were detected in positive and/or in negative ion mode using DART. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Biological and chemical weapons of mass destruction: updated clinical therapeutic countermeasures since 2003.

    Science.gov (United States)

    Pettineo, Christopher; Aitchison, Robert; Leikin, Scott M; Vogel, Stephen N; Leikin, Jerrold B

    2009-01-01

    The objective of this article is to provide updated treatment options for bioterrorism agents. This updated synopsis includes recent clinical cases and treatment recommendations that have arisen in the last 5 years. The decontamination, treatment, and disposition of these biologic and chemical agents are presented alphabetically by agent type: biologic, chemical, and radiologic/nuclear. The information provided outlines only new treatment options since 2003.

  18. Ionised gas structure of 100 kpc in an over-dense region of the galaxy group COSMOS-Gr30 at z 0.7

    Science.gov (United States)

    Epinat, B.; Contini, T.; Finley, H.; Boogaard, L. A.; Guérou, A.; Brinchmann, J.; Carton, D.; Michel-Dansac, L.; Bacon, R.; Cantalupo, S.; Carollo, M.; Hamer, S.; Kollatschny, W.; Krajnović, D.; Marino, R. A.; Richard, J.; Soucail, G.; Weilbacher, P. M.; Wisotzki, L.

    2018-01-01

    We report the discovery of a 104 kpc2 gaseous structure detected in [O II]λλ3727, 3729 in an over-dense region of the COSMOS-Gr30 galaxy group at z 0.725 with deep MUSE Guaranteed Time Observations. We estimate the total amount of diffuse ionised gas to be of the order of ( 5 ± 3) × 1010 M⊙ and explore its physical properties to understand its origin and the source(s) of the ionisation. The MUSE data allow the identification of a dozen group members that are embedded in this structure through emission and absorption lines. We extracted spectra from small apertures defined for both the diffuse ionised gas and the galaxies. We investigated the kinematics and ionisation properties of the various galaxies and extended gas regions through line diagnostics (R23, O32, and [O III]/Hβ) that are available within the MUSE wavelength range. We compared these diagnostics to photo-ionisation models and shock models. The structure is divided into two kinematically distinct sub-structures. The most extended sub-structure of ionised gas is likely rotating around a massive galaxy and displays filamentary patterns that link some galaxies. The second sub-structure links another massive galaxy that hosts an active galactic nucleus (AGN) to a low-mass galaxy, but it also extends orthogonally to the AGN host disc over 35 kpc. This extent is likely ionised by the AGN itself. The location of small diffuse regions in the R23 vs. O32 diagram is compatible with photo-ionisation. However, the location of three of these regions in this diagram (low O32, high R23) can also be explained by shocks, which is supported by their high velocity dispersions. One edge-on galaxy shares the same properties and may be a source of shocks. Regardless of the hypothesis, the extended gas seems to be non-primordial. We favour a scenario where the gas has been extracted from galaxies by tidal forces and AGN triggered by interactions between at least the two sub-structures. Based on observations made with

  19. Extra holiday because of ionising radiation not necessary

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    The 'regulations for special measures to protect employees working with X-rays and radium radiation' of 21st November 1947, which included a statutory six-week holiday period annually, has now been superceded by 'regulations on special protective measures for work with ionising radiation', issued by the Directorate for Work Inspection on 31st March 1978, effective from 1st May 1978. In addition to removing the requirement for six weeks annual holiday for radiation personnel, routine medical surveillance is only required every third year instead of annually. A number of other changes are mentioned. The basis for these changes is that continuous personnel dosimetry and better knowledge of the effects of ionising radiation allows any necessary measures to be taken on the basis of these. (JIW)

  20. Atmospheric pressure chemical ionization Fourier transform ion cyclotron resonance mass spectrometry for complex thiophenic mixture analysis

    KAUST Repository

    Hourani, Nadim; Andersson, Jan T.; Mö ller, Isabelle; Amad, Maan H.; Witt, Matthí as; Sarathy, Mani

    2013-01-01

    oil (VGO) and injected using the same method. The samples were analyzed using Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS). RESULTS PASH model analytes were successfully ionized and mainly [M + H]+ ions were produced. The same

  1. Medical use of ionising radiation - challenges for the third millennium

    International Nuclear Information System (INIS)

    Leitz, W.

    2003-01-01

    From the very beginning after its discovery ionising radiation has been in beneficial use for health care. But even the drawbacks showed up very early: only a few months after Roentgens discovery reports were published on patients who got severe skin damage after fluoroscopy with x-rays. This finding of the adverse effects was soon turned into something positive: ionising radiation could be used for treatment of cancer. In 1928 radiologists took the initiative to the foundation of what later became the International Commission on Radiological Protection, ICRP. Medical use of ionising radiation is giving by far the largest contribution to the radiation burden of the global population from artificial sources, on average 0,3 mSv per year and inhabitant, excluding doses from radiation treatment. In the Nordic countries this dose is approximately 0,7 mSv. This isn't a problem by itself. The total benefit is exceeding the total radiation risk with large margins. But the margins could even be larger. Methods for examinations and treatments have often a potential for improvements, meaning that the medical effect can be obtained with a lower dose to the patient. In certain circumstances the examination does not contribute to the further treatment of the patient or to her/his well-being and is then regarded as not justified. The huge challenge we are facing depends among other things on the extreme fast technical development which enables exposures of a magnitude that we haven't seen before and applications we only could dream about. There is a risk that the motto 'do what is possible to do' is followed instead of 'do what the individual patient needs'. This presentation addresses the possibilities, but also the dangers that medical use of ionising radiation in medical care is facing in the new millennium, or at least in its first years. (orig.)

  2. Basic radiation chemistry for the ionising energy treatment of food

    International Nuclear Information System (INIS)

    Moore, P.W.

    1985-01-01

    Before we can understand the chemistry involved in the irradiation of complex substances such as food we need to have some appreciation of the reactions involved and the products formed when ionising energy interacts with the simple substances such as water and dilute solutions. Reactions involving hydrated electrons, hydrogen atoms and hydroxyl radicals are examined and methods for minimising radiolytic effects in foods are discussed

  3. Two-dimensional readout in a liquid xenon ionisation chamber

    CERN Document Server

    Solovov, V; Ferreira-Marques, R; Lopes, M I; Pereira, A; Policarpo, Armando

    2002-01-01

    A two-dimensional readout with metal strips deposited on both sides of a glass plate is investigated aiming to assess the possibility of its use in a liquid xenon ionisation chamber for positron emission tomography. Here, we present results obtained with an alpha-source. It is shown that position resolution of <=1 mm, fwhm, can be achieved for free charge depositions equivalent to those due to gamma-rays with energy from 220 down to 110 keV.

  4. Conversion of electromagnetic waves at the ionisation front

    International Nuclear Information System (INIS)

    Chegotov, M V

    2001-01-01

    It is shown that a weak electromagnetic pulse interacting with a copropagating ionisation front is converted in the general case into three electromagnetic pulses with higher and lower frequencies, which propagate in different directions. The coefficients of conversion to these pulses (for intensities) were found as functions of the frequency. The electromagnetic energy is shown to decrease during this conversion because of the losses for the residual electron energy. (interaction of laser radiation with matter. laser plasma)

  5. Fully kinetic simulations of magnetic reconnection in partially ionised gases

    Science.gov (United States)

    Innocenti, M. E.; Jiang, W.; Lapenta, G.; Markidis, S.

    2016-12-01

    Magnetic reconnection has been explored for decades as a way to convert magnetic energy into kinetic energy and heat and to accelerate particles in environments as different as the solar surface, planetary magnetospheres, the solar wind, accretion disks, laboratory plasmas. When studying reconnection via simulations, it is usually assumed that the plasma is fully ionised, as it is indeed the case in many of the above-mentioned cases. There are, however, exceptions, the most notable being the lower solar atmosphere. Small ionisation fractions are registered also in the warm neutral interstellar medium, in dense interstellar clouds, in protostellar and protoplanetary accreditation disks, in tokamak edge plasmas and in ad-hoc laboratory experiments [1]. We study here how magnetic reconnection is modified by the presence of a neutral background, i.e. when the majority of the gas is not ionised. The ionised plasma is simulated with the fully kinetic Particle-In-Cell (PIC) code iPic3D [2]. Collisions with the neutral background are introduced via a Monte Carlo plug-in. The standard Monte Carlo procedure [3] is employed to account for elastic, excitation and ionization electron-neutral collisions, as well as for elastic scattering and charge exchange ion-neutral collisions. Collisions with the background introduce resistivity in an otherwise collisionless plasma and modifications of the particle distribution functions: particles (and ions at a faster rate) tend to thermalise to the background. To pinpoint the consequences of this, we compare reconnection simulations with and without background. References [1] E E Lawrence et al. Physical review letters, 110(1):015001, 2013. [2] S Markidis et al. Mathematics and Computers in Simulation, 80(7):1509-1519, 2010. [3] K Nanbu. IEEE Transactions on plasma science, 28(3):971-990, 2000.

  6. Ionising radiation safety training in the Australian Defence Organisation (ADO)

    International Nuclear Information System (INIS)

    Jenks, G.J.; O'Donovan, E.J.B.; Wood, W.B.

    1998-01-01

    Training personnel in ionising radiation safety within the Australian Defence Organisation (ADO) requires addressing some unique features of an organisation employing both military and civilian personnel. Activities may include those of a civil nature (such as industrial and medical radiography), specific military requirements (for training and emergency response) and scientific research and development. Some personnel may be assigned to full-time duties associated with radiation. However, most are designated as radiation protection officers as a secondary duty. A further complication is that most military personnel are subjected to postings at regular intervals. The ADO's Directorate of Defence Occupational Health and Safety has established an Ionising Radiation Safety Subcommittee to monitor not only the adequacy of the internal Ionising Radiation Safety Manual but also the training requirements. A Training Course, responding to these requirements, has been developed to emphasize, basic radiation theory and protection, operation of radiation monitors available in the ADO, an understanding of the Ionising Radiation Safety Manual, day-to-day radiation safety in units and establishments, and appropriate responses to radiation accidents and emergencies. In addition, students are briefed on a limited number of peripheral topics and participate in some site visits. Currently, two Courses are held annually, each with about twenty students. Most of the material is presented by ADO personnel with external contractor support. The three Courses held to date have proved successful, both for the students and the ADO generally. To seek national accreditation of the course through the Australian National Training Authority, as a first step, competency standards have been proposed. (authors)

  7. Erich Regener and the ionisation maximum of the atmosphere

    Science.gov (United States)

    Carlson, P.; Watson, A. A.

    2014-12-01

    In the 1930s the German physicist Erich Regener (1881-1955) did important work on the measurement of the rate of production of ionisation deep under water and in the atmosphere. Along with one of his students, Georg Pfotzer, he discovered the altitude at which the production of ionisation in the atmosphere reaches a maximum, often, but misleadingly, called the Pfotzer maximum. Regener was one of the first to estimate the energy density of cosmic rays, an estimate that was used by Baade and Zwicky to bolster their postulate that supernovae might be their source. Yet Regener's name is less recognised by present-day cosmic ray physicists than it should be, largely because in 1937 he was forced to take early retirement by the National Socialists as his wife had Jewish ancestors. In this paper we briefly review his work on cosmic rays and recommend an alternative naming of the ionisation maximum. The influence that Regener had on the field through his son, his son-in-law, his grandsons and his students, and through his links with Rutherford's group in Cambridge, is discussed in an appendix. Regener was nominated for the Nobel Prize in Physics by Schrödinger in 1938. He died in 1955 at the age of 73.

  8. IRID: specifications for the Ionising Radiations Incident Database

    International Nuclear Information System (INIS)

    Thomas, G.O.; Croft, J.R.; Williams, M.K.; McHugh, J.O.

    1996-01-01

    Technologies that make use of ionising radiations are widespread. They provide many benefits but, as with other technologies, the use of ionising radiations carries with it the potential for incidents and accidents. Their severity can vary from the trivial to the fatal and may involve substantial economic penalties. In order to minimise the number of incidents and their consequences it is important that there is a mechanism to learn the lessons from those that do occur. To help pursue this objective the National Radiological Protection Board, the Health and Safety Executive and the Environment Agency have established a national Ionising Radiations Incident Database (IRID) to cover radiation incidents in industry, medicine, research and teaching. This publication details the specifications for IRID and its methods of operation. All information in the database will be unattributable and names of persons or organisations will not be included. It is a personal computer based system with 24 fields to categorise an incident, including a text field that will provide a description of the incident giving the causes, consequences, follow-up actions and lessons to be learned. These descriptions will be used in subsequent publications to provide feedback to the users. (UK)

  9. Additives in UV and ionising radiation grafting and curing processes

    International Nuclear Information System (INIS)

    Garnett, J.L.; Ng, L.T.; Viengkhou, V.

    1998-01-01

    Full text: Curing of polymers induced by both UV and ionising radiation are now established technologies. Currently both systems are predominantly based on acrylate chemistry. UV processes use photoinitiators to achieve fast polymerisation. In the proposed paper the significance of the occurrence of concurrent grafting with cure will be examined. particularly with respect to the recycling of finished product. Basic studies on grafting initiated by UV and ionising radiation will be discussed. Polar methyl methacrylate (MMA) and non-polar styrene will be used as representative monomers with cellulose and propylene typifying the backbone polymers. The additives chosen for examination in this study are predominantly components used in radiation curing formulations since grafting and curing are known to be mechanically related. The additives used were mineral acid, photoinitiators, vinyl ethers, oligomers, polyfunctional monomers including multifunctional acrylates (MFAs) and methacrylates (MFMAs). For the first time the use of charge transfer complexes in the Mulliken sense as additives in radiation grafting will be discussed. The CT complexes themselves, being monomers, have also been grafted to the above polymers. Recent developments with excimer laser sources for initiating these processes will be discussed, especially the use of non-acrylate chemistry. Excimer laser sources are shown to complement conventional UV and ionising radiation and are photoinitiator free. Mechanisms for the above grafting and curing processes will be outlined

  10. Sensitivity of gaseous xenon ionisation chambers (1961); Sensibilite des chambres d'ionisation a xenon gazeux (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Schuhl, C [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    It seems advantageous to fill an ionization chamber with xenon gas when this chamber is used for measuring a low intensity and high energy electron or positron beam, or monitoring a gamma beam. In the study of 5 to 50 MeV electrons, xenon allows for the ionization chamber yield, an improvement of a factor 4,5. (author) [French] Il apparait interessant d'utiliser du xenon comme gaz dans une chambre d'ionisation destinee a mesurer un faisceau d'electrons ou de positons de faible intensite et de grande energie ou pour monitorer un faisceau de gamma. Dans les etudes des electrons de 5 a 50 MeV, le xenon permet de gagner un facteur 4,5 sur l'air pour la sensibilite d'une chambre d'ionisation. (auteur)

  11. In-source collision induced dissociation of inorganic explosives for mass spectrometric signature detection and chemical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Forbes, Thomas P., E-mail: thomas.forbes@nist.gov; Sisco, Edward

    2015-09-10

    The trace detection, bulk quantification, and chemical imaging of inorganic explosives and components was demonstrated utilizing in-source collision induced dissociation (CID) coupled with laser desorption/ionization mass spectrometry (LDI-MS). The incorporation of in-source CID provided direct control over the extent of adduct and cluster fragmentation as well as organic noise reduction for the enhanced detection of both the elemental and molecular ion signatures of fuel-oxidizer mixtures and other inorganic components of explosive devices. Investigation of oxidizer molecular anions, specifically, nitrates, chlorates, and perchlorates, identified that the optimal in-source CID existed at the transition between fragmentation of the ionic salt bonds and molecular anion bonds. The chemical imaging of oxidizer particles from latent fingerprints was demonstrated, including both cation and anion components in positive and negative mode mass spectrometry, respectively. This investigation demonstrated LDI-MS with in-source CID as a versatile tool for security fields, as well as environmental monitoring and nuclear safeguards, facilitating the detection of elemental and molecular inorganic compounds at nanogram levels. - Highlights: • In-source CID enhanced detection of elemental inorganics up to 1000-fold. • In-source CID optimization of polyatomic oxidizers enhanced detection up to 100-fold. • Optimal CID identified at transition from breaking ionic salt to molecular anion bonds. • Trace detection of inorganic explosives at nanogram levels was demonstrated. • Oxidizer particles were chemically imaged directly from latent fingerprints.

  12. Mass spectral analysis of N-oxides of Chemical Weapons Convention related aminoethanols under electrospray ionization conditions.

    Science.gov (United States)

    Sridhar, L; Karthikraj, R; Murty, M R V S; Raju, N Prasada; Vairamani, M; Prabhakar, S

    2011-02-28

    N,N'-Dialkylaminoethanols are the hydrolyzed products or precursors of chemical warfare agents such as V-agents and nitrogen mustards, and they are prone to undergo oxidation in environmental matrices or during decontamination processes. Consequently, screening of the oxidized products of aminoethanols in aqueous samples is an important task in the verification of chemical weapons convention-related chemicals. Here we report the successful characterization of the N-oxides of N,N'-dialkylaminoethanols, alkyl diethanolamines, and triethanolamine using positive ion electrospray ionization mass spectrometry. The collision-induced dissociation (CID) spectra of the [M+H](+) and [M+Na](+) ions show diagnostic product ions that enable the unambiguous identification of the studied N-oxides, including those of isomeric compounds. The proposed fragmentation pathways are supported by high-resolution mass spectrometry data and product/precursor ion spectra. The CID spectra of [M+H](+) ions included [MH-CH(4)O(2)](+) as the key product ion, in addition to a distinctive alkene loss that allowed us to recognize the alkyl group attached to the nitrogen. The [M+Na](+) ions show characteristic product ions due to the loss of groups (R) attached to nitrogen either as a radical (R) or as a molecule [R+H or (R-H)] after hydrogen migration. Copyright © 2011 John Wiley & Sons, Ltd.

  13. Chemical discrimination of lubricant marketing types using direct analysis in real time time-of-flight mass spectrometry.

    Science.gov (United States)

    Maric, Mark; Harvey, Lauren; Tomcsak, Maren; Solano, Angelique; Bridge, Candice

    2017-06-30

    In comparison to other violent crimes, sexual assaults suffer from very low prosecution and conviction rates especially in the absence of DNA evidence. As a result, the forensic community needs to utilize other forms of trace contact evidence, like lubricant evidence, in order to provide a link between the victim and the assailant. In this study, 90 personal bottled and condom lubricants from the three main marketing types, silicone-based, water-based and condoms, were characterized by direct analysis in real time time of flight mass spectrometry (DART-TOFMS). The instrumental data was analyzed by multivariate statistics including hierarchal cluster analysis, principal component analysis, and linear discriminant analysis. By interpreting the mass spectral data with multivariate statistics, 12 discrete groupings were identified, indicating inherent chemical diversity not only between but within the three main marketing groups. A number of unique chemical markers, both major and minor, were identified, other than the three main chemical components (i.e. PEG, PDMS and nonoxynol-9) currently used for lubricant classification. The data was validated by a stratified 20% withheld cross-validation which demonstrated that there was minimal overlap between the groupings. Based on the groupings identified and unique features of each group, a highly discriminating statistical model was then developed that aims to provide the foundation for the development of a forensic lubricant database that may eventually be applied to casework. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Chemical mass balance source apportionment of TSP in a lignite-burning area of Western Macedonia, Greece

    Science.gov (United States)

    Samara, Constantini

    Total suspended particle mass concentrations (TSP) were determined in the Kozani-Ptolemais-Florina basin (western Macedonia, Greece), an area with intensive lignite burning for power generation. The study was conducted over a 1-year period (November 2000-November 2001) at 10 receptor sites located at variable distances from the power plants. Ambient TSP samples were analyzed for 27 major, minor and trace elements. Particulate emissions were also collected from a variety of sources including fly ash, lignite dust, automobile traffic, domestic heating, and open-air burning of agricultural biomass and refuse, and analyzed for the same chemical components. Ambient and source chemical profiles were used for source identification and apportionment of TSP by employing a chemical mass balance (CMB) receptor model. Diesel burning in vehicular traffic and in the power plants for generator start up was found to be the major contributor to ambient TSP levels at all 10 sites. Other sources with significant contributions were domestic coal burning, vegetative burning (wood combustion and agricultural burns) and refuse open-air burning. Fly ash escaping the electrostatic precipitators of the power plants was a minor contributor to ambient TSP.

  15. Fluorographene as a Mass Spectrometry Probe for High-Throughput Identification and Screening of Emerging Chemical Contaminants in Complex Samples.

    Science.gov (United States)

    Huang, Xiu; Liu, Qian; Huang, Xiaoyu; Nie, Zhou; Ruan, Ting; Du, Yuguo; Jiang, Guibin

    2017-01-17

    Mass spectrometry techniques for high-throughput analysis of complex samples are of profound importance in many areas such as food safety, omics studies, and environmental health science. Here we report the use of fluorographene (FG) as a new mass spectrometry probe for high-throughput identification and screening of emerging chemical contaminants in complex samples. FG was facilely synthesized by one-step exfoliation of fluorographite. With FG as a matrix or probe in matrix-assisted or surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (MALDI- or SELDI-TOF MS), higher sensitivity (detection limits at ppt or subppt levels), and better reproducibility were achieved than with other graphene-based materials due to the unique chemical structure and self-assembly properties of FG. The method was validated with different types of real complex samples. By using FG as a SELDI probe, we could easily detect trace amount of bisphenol S in paper products and high-fat canned food samples. Furthermore, we have successfully identified and screened as many as 28 quaternary ammonium halides in sewage sludge samples collected from municipal wastewater treatment plants. These results demonstrate that FG probe is a powerful tool for high-throughput analysis of complex samples by MS.

  16. CHEMICALS

    CERN Multimedia

    Medical Service

    2002-01-01

    It is reminded that all persons who use chemicals must inform CERN's Chemistry Service (TIS-GS-GC) and the CERN Medical Service (TIS-ME). Information concerning their toxicity or other hazards as well as the necessary individual and collective protection measures will be provided by these two services. Users must be in possession of a material safety data sheet (MSDS) for each chemical used. These can be obtained by one of several means : the manufacturer of the chemical (legally obliged to supply an MSDS for each chemical delivered) ; CERN's Chemistry Service of the General Safety Group of TIS ; for chemicals and gases available in the CERN Stores the MSDS has been made available via EDH either in pdf format or else via a link to the supplier's web site. Training courses in chemical safety are available for registration via HR-TD. CERN Medical Service : TIS-ME :73186 or service.medical@cern.ch Chemistry Service : TIS-GS-GC : 78546

  17. On ionising radiation and breast cancer risk

    Energy Technology Data Exchange (ETDEWEB)

    Mattson, Anders

    1999-05-01

    A cohort of 3,090 women with clinical diagnosis of benign breast disease (BBD) was studied. Of these, 1,216 were treated with radiation therapy during 1925-54 (median age 40 years). The mean dose to the breasts was 5.8 Gy (range 0-50 Gy). Among other organs the lung received the highest scattered dose (0.75 Gy; range 0.004-8.98 Gy) and the rectum the lowest (0.008 Gy; range 0-0.06 Gy). A pooled analysis of eight breast cancer incidence cohorts was done, including: tumour registry data on breast cancer incidence among women in the Life Span Study cohort of atomic bomb survivors; women in Massachusetts who received repeated chest fluoroscopic during lung collapse treatment for tuberculosis; women who received x-ray therapy for acute post-partum mastitis; women who were irradiated in infancy for enlarged thymus glands ; two Swedish cohorts of women who received radiation treatments during infancy for skin hemangioma; and the BBD cohort. Together the cohorts included almost 78,000 women (-35,000 were exposed), around 1.8 million woman-years and 1500 cases. The breast cancer incidence rate as a function of breast dose was analysed using linear-quadratic Poisson regression models. Cell-killing effects and other modifying effects were incorporated through additional log-linear terms. Additive (EAR) and multiplicative (ERR) models were compared in estimating the age-at-exposure patterns and time related excess. The carcinogenic risks associated with radiation in mammographic mass screening is evaluated. Assessment was made in terms of breast cancer mortality and years of life. Effects were related to rates not influenced by a mammographic mass screening program and based on a hypothetical cohort of 100,000 40-year old women with no history of breast cancer being followed to 100 years of age. Two radiation risk assumptions were compared. The dose-response relationship is linear with little support in data for an upward curvature at low to medium doses. The competing effect

  18. On ionising radiation and breast cancer risk

    International Nuclear Information System (INIS)

    Mattson, Anders

    1999-01-01

    A cohort of 3,090 women with clinical diagnosis of benign breast disease (BBD) was studied. Of these, 1,216 were treated with radiation therapy during 1925-54 (median age 40 years). The mean dose to the breasts was 5.8 Gy (range 0-50 Gy). Among other organs the lung received the highest scattered dose (0.75 Gy; range 0.004-8.98 Gy) and the rectum the lowest (0.008 Gy; range 0-0.06 Gy). A pooled analysis of eight breast cancer incidence cohorts was done, including: tumour registry data on breast cancer incidence among women in the Life Span Study cohort of atomic bomb survivors; women in Massachusetts who received repeated chest fluoroscopic during lung collapse treatment for tuberculosis; women who received x-ray therapy for acute post-partum mastitis; women who were irradiated in infancy for enlarged thymus glands ; two Swedish cohorts of women who received radiation treatments during infancy for skin hemangioma; and the BBD) cohort. Together the cohorts included almost 78,000 women (-35,000 were exposed), around 1.8 million woman-years and 1500 cases. The breast cancer incidence rate as a function of breast dose was analysed using linear-quadratic Poisson regression models. Cell-killing effects and other modifying effects were incorporated through additional log-linear terms. Additive (EAR) and multiplicative (ERR) models were compared in estimating the age-at-exposure patterns and time related excess. The carcinogenic risks associated with radiation in mammographic mass screening is evaluated. Assessment was made in terms of breast cancer mortality and years of life. Effects were related to rates not influenced by a mammographic mass screening program and based on a hypothetical cohort of 100,000 40-year old women with no history of breast cancer being followed to 100 years of age. Two radiation risk assumptions were compared. The dose-response relationship is linear with little support in data for an upward curvature at low to medium doses. The competing effect

  19. Biological Effects of Ionising Radiation and Countermeasures (Les effets biologiques des rayonnements ionisants et leurs contre-mesures)

    Science.gov (United States)

    2018-01-01

    radiation physicists. As an example, a special issue of Health Physics [3] presents a body of experimental work characterizing the outdoor...Terrorist Attack involving Ionising Radiation. Campus Vesta, Belgium September 25-29, 2016. [3] Health Physics (Special Issue) 2016:110;399- 547...of Radiobiology & Radiation Protection 128 Szaserów Street 04-141 Warsaw POLAND Email: mjaniak@wihe.waw.pl Mr. Tjerk KUIPERS Health Physics

  20. Air mass origins influencing TTL chemical composition over West Africa during 2006 summer monsoon

    Directory of Open Access Journals (Sweden)

    K. S. Law

    2010-11-01

    Full Text Available Trace gas and aerosol data collected in the tropical tropopause layer (TTL between 12–18.5 km by the M55 Geophysica aircraft as part of the SCOUT-AMMA campaign over West Africa during the summer monsoon in August 2006 have been analysed in terms of their air mass origins. Analysis of domain filling back trajectories arriving over West Africa, and in the specific region of the flights, showed that the M55 flights were generally representative of air masses arriving over West Africa during the first 2 weeks of August, 2006. Air originating from the mid-latitude lower stratosphere was under-sampled (in the mid-upper TTL whilst air masses uplifted from central Africa (into the lower TTL were over-sampled in the latter part of the campaign. Signatures of recent (previous 10 days origins were superimposed on the large-scale westward flow over West Africa. In the lower TTL, air masses were impacted by recent local deep convection over Africa at the level of main convective outflow (350 K, 200 hPa and on certain days up to 370 K (100 hPa. Estimates of the fraction of air masses influenced by local convection vary from 10 to 50% depending on the method applied and from day to day during the campaign. The analysis shows that flights on 7, 8 and 11 August were more influenced by local convection than on 4 and 13 August allowing separation of trace gas and aerosol measurements into "convective" and "non-convective" flights. Strong signatures, particularly in species with short lifetimes (relative to CO2 like CO, NO and fine-mode aerosols were seen during flights most influenced by convection up to 350–365 K. Observed profiles were also constantly perturbed by uplift (as high as 39% of air masses from the mid to lower troposphere over Asia, India, and oceanic regions resulting in import of clean oceanic (e.g. O3-poor or polluted air masses from Asia (high O3, CO, CO2 into West Africa. Thus, recent uplift of CO

  1. Determination of isotope ratio of elements by mass distribution in molecules of varied chemical compounds

    International Nuclear Information System (INIS)

    Gladkikh, I.S.; Babichev, A.P.

    1999-01-01

    The procedure and program for calculation of isotope ratio of elements involving in the compound being studied using data of mass spectrometry were elaborated. The methods developed for the O 2 , SiH 4 , Cd(CH 3 ) 2 molecules were demonstrated for the illustration. The results of calculation provide support for the efficiency of the program and satisfactory reliability of the results during calculation of the isotope and complex compound concentrations. The program may be used for the estimation of the degree of nonequilibrium isotope distributions, it may indicate on the errors of the mass spectroscopy results [ru

  2. Method of obtaining an anode mass for primary chemical current sources

    Energy Technology Data Exchange (ETDEWEB)

    Cyrankowska, M.; Kwasnik, J.; Sobkowiak, J.

    1981-12-31

    The Zn powder is mixed with thickner protecting the Zn from the oxidation effect of the air during subsequent amalgamation. Alkaline electrolyte which governs dissolving of the ZnO film formed on the Zn grains is added to the dry mixture. The mixture is mixed until the formation of a uniform plastic mass, after which metal mecury is added to it. The method makes it possible to reduce corrosion of Zn both during preparation of the active mass and during assembly of the electrode.

  3. 2007 Joint Chemical Biological, Radiological and Nuclear (CBRN) Conference and Exhibition - Combating Weapons of Mass Destruction

    Science.gov (United States)

    2007-06-27

    Selected CB Defense Systems SHAPESENSE Joint Warning and Reporting Network JSLIST CB Protected Shelter Joint Vaccine Acquisition Program Joint Effects...military can operate in any environment, unconstrained by chemical or biological weapons. 21 SHIELD SUSTAIN Selected CB Defense Systems SHAPESENSE Joint...28070625_JCBRN_Conference_Reeves UNCLASSIFIED Decontamination Vision Strippable Barriers Self-Decontaminating Fabrics/Coatings Reduce Logistics Burden

  4. Aerosol Chemical Mass Closure during the EUROTRAC-2 AEROSOL Intercomparison 2000

    Czech Academy of Sciences Publication Activity Database

    Maenhaut, W.; Schwarz, Jaroslav; Cafmeyer, J.; Chi, X.

    2002-01-01

    Roč. 186, - (2002), s. 233-237 ISSN 0168-583X Institutional research plan: CEZ:AV0Z4072921 Keywords : ion chromatography * chemical composition * atmospheric aerosols Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.158, year: 2002

  5. Thermoluminescent properties of CVD diamond: applications to ionising radiation dosimetry; Proprietes thermoluminescentes du diamant CVD: applications a la dosimetrie des rayonnements ionisants

    Energy Technology Data Exchange (ETDEWEB)

    Petitfils, A

    2007-09-15

    Remarkable properties of synthetic diamond (human soft tissue equivalence, chemical stability, non-toxicity) make this material suitable for medical application as thermoluminescent dosimeter (TLD). This work highlights the interest of this material as radiotherapy TLD. In the first stage of this work, we looked after thermoluminescent (TL) and dosimetric properties of polycrystalline diamond made by Chemically Vapor Deposited (CVD) synthesis. Dosimetric characteristics are satisfactory as TLD for medical application. Luminescence thermal quenching on diamond has been investigated. This phenomenon leads to a decrease of dosimetric TL peak sensitivity when the heating rate increases. The second part of this work analyses the use of synthetic diamond as TLD in radiotherapy. Dose profiles, depth dose distributions and the cartography of an electron beam obtained with our samples are in very good agreement with results from an ionisation chamber. It is clearly shown that CVD) diamond is of interest to check beams of treatment accelerators. The use of these samples in a control of treatment with Intensity Modulated Radiation Therapy underlines good response of synthetic diamond in high dose gradient areas. These results indicate that CVD diamond is a promising material for radiotherapy dosimetry. (author)

  6. Ionising radiation effects on food packaging

    International Nuclear Information System (INIS)

    Ragni, P.; Segre, A. L.; Capitani, D.; Danesi, P.R.

    2001-01-01

    The main aim of any food irradiation treatment is to guarantee the best safe quality of the products, reducing the spreading risk ( c ross-contamination ) for several food-associated diseases. Actually, over 40 countries provide clearances for the treatment of about 45 different types of foodstuffs. EU has to homogenise the situation within the associated States. With the European directive 1999/2/EC Italy, as other EU countries, already has brought into force their regulations to comply. The current Italian regulation on irradiation treatment of foodstuffs is referred since 1996 as follows: a) potatoes, onions and garlic; b) spices, herbs and condiments microbial. The new (April 2001) Italian law allows the possibility to ask for special permission of treatment for other foodstuff which is possible to treat in other E.U. countries. Large majority of foods are submitted to irradiation treatment after they have been packaged. In Dutch cases the study of radiation effects on the package becomes crucial, also because polymeric materials may be affected by ionizing radiation. We performed our studies on several materials employed in food packaging, with a particular care to the role of anti-oxidant additives present in food packaging materials. The attention is pointed on the possible chemical-physical effects induced by radiation on foodstuff packaging. After irradiation in plastic materials two main effects may occur: degradation and cross-linking. The result depending on the comparative rates of the two actions. This kind of information was successfully obtained using NMR methods on a large number of polymers effectively used for the food packaging procedures

  7. Semiclassical calculation of ionisation rate for Rydberg helium atoms in an electric field

    International Nuclear Information System (INIS)

    Wang De-Hua

    2011-01-01

    The ionisation of Rydberg helium atoms in an electric field above the classical ionisation threshold has been examined using the semiclassical method, with particular emphasis on discussing the influence of the core scattering on the escape dynamics of electrons. The results show that the Rydberg helium atoms ionise by emitting a train of electron pulses. Unlike the case of the ionisation of Rydberg hydrogen atom in parallel electric and magnetic fields, where the pulses of the electron are caused by the external magnetic field, the pulse trains for Rydberg helium atoms are created through core scattering. Each peak in the ionisation rate corresponds to the contribution of one core-scattered combination trajectory. This fact further illustrates that the ionic core scattering leads to the chaotic property of the Rydberg helium atom in external fields. Our studies provide a simple explanation for the escape dynamics in the ionisation of nonhydrogenic atoms in external fields. (atomic and molecular physics)

  8. Authentication of organically and conventionally grown basils by gas chromatograpy/mass spectrometry chemical profiles

    Science.gov (United States)

    Basil plants cultivated by organic and conventional farming practices were differentiated using gas chromatography/mass spectrometry (GC/MS) and chemometric methods. The two-way GC/MS data sets were baseline-corrected and retention time-aligned prior to data processing. Two self-devised fuzzy clas...

  9. Effect of chemical redox on Gd-doped ceria mass diffusion

    DEFF Research Database (Denmark)

    Ni, De Wei; de Florio, D.Z.; Marani, Debora

    2015-01-01

    The valence and size of cations influence mass diffusion and oxygen defects in ceria. Here we show that reduction of Ce4+ to Ce3+, at high temperatures and low oxygen activity, activates fast diffusion mechanisms which depend on the aliovalent cation concentration. As a result, polycrystalline so...... solid solutions with enhanced electrochemical properties are formed....

  10. Desorption electrospray ionization mass spectrometry in the analysis of chemical food contaminants in food

    NARCIS (Netherlands)

    Nielen, M.W.F.; Hooijerink, H.; Zomer, P.; Mol, J.G.J.

    2011-01-01

    Since its introduction, desorption electrospray ionization (DESI) mass spectrometry (MS) has been mainly applied in pharmaceutical and forensic analysis. We expect that DESI will find its way in many different fields, including food analysis. In this review, we summarize DESI developments aimed at

  11. [Mass spectrometric and quantum chemical study of dimeric associates of nucleosides].

    Science.gov (United States)

    Sukhodub, L F; Aksenov, S A; Boldeskul, A I

    1995-01-01

    Deoxyribonucleosides H-bonded pairs were investigated using fast atom bombardment mass spectrometry and MNDO/H quantum chemistry method. It was shown that "rare" (enol or imin) forms of the nitrogen bases could form pairs with energy comparable with "canonical" base pair energy. It was shown that pair stability rows, which are measured using different experimental techniques, were in conformity each with other.

  12. IDENTIFICATION OF DEGRADATION PRODUCTS OF SOME CHEMICAL WARFARE AGENTS BY CAPILLARY ELECTROPHORESIS IONSPRAY MASS-SPECTROMETRY

    NARCIS (Netherlands)

    KOSTIAINEN, R; BRUINS, AP; HAKKINEN, VMA

    1993-01-01

    Capillary zone electrophoresis-ionspray mass spectrometry (CZE-IS-MS) in the negative-ion mode was applied in the identification of five organophosphonic acids, which are the primary hydrolysis products of nerve agents. The spectra exhibit a very abundant (M - H)- ion with minimal fragmentation.

  13. Insights in luteovirid structural biology guided by chemical cross-linking and high resolution mass spectrometry

    Science.gov (United States)

    Interactions among plant pathogenic viruses in the family /react-text Luteoviridae react-text: 233 and their plant hosts and insect vectors are governed by the topology of the viral capsid, which is the sole vehicle for long distance movement of the viral genome. Previous application of a mass spect...

  14. Ionization mechanisms in capillary supercritical fluid chromatography-chemical ionization mass spectrometry

    NARCIS (Netherlands)

    Houben, R.J.; Leclercq, P.A.; Cramers, C.A.M.G.

    1991-01-01

    Ionization mechanisms have been studied for supercritical fluid chromatography (SFC) with mass spectrometric (MS) detection. One of the problems associated with SFC-MS is the interference of mobile phase constituents in the ionization process, which complicates the interpretation of the resulting

  15. The pivotal role of mass spectrometry in determining the presence of chemical contaminants in food raw materials.

    Science.gov (United States)

    Mohamed, Rayane; Guy, Philippe A

    2011-01-01

    During recent years, a rising interest from consumers and various governmental organizations towards the quality of food has continuously been observed. Human intervention across the different stages of the food supply chain can lead to the presence of several types of chemical contaminants in food-based products. On a normal daily consumption basis, some of these chemicals are not harmful; however, for those that present a risk to consumers, legislation rules were established to specify tolerance levels or in some cases the total forbiddance of these specific contaminants. Hence, the use of appropriate analytical tools is recommended to properly identify chemical contaminants. In that context, mass spectrometry (MS)-based techniques coupled or not to chromatography offer a vast panel of features such as sensitivity, selectivity, quantification at trace levels, and/or structural elucidation. Because of the complexity of food-based matrices, sample preparation is a crucial step before final detection. In the present manuscript, we review the contribution and the potentialities of MS-based techniques to ensure the absence of chemical contaminants in food-based products. Copyright © 2011 Wiley Periodicals, Inc.

  16. Chemical profile of pineapple cv. Vitória in different maturation stages using electrospray ionization mass spectrometry.

    Science.gov (United States)

    Ogawa, Elizângela M; Costa, Helber B; Ventura, José A; Caetano, Luiz Cs; Pinto, Fernanda E; Oliveira, Bruno G; Barroso, Maria Eduarda S; Scherer, Rodrigo; Endringer, Denise C; Romão, Wanderson

    2018-02-01

    Pineapple is the fruit of Ananas comosus var. comosus plant, being cultivated in tropical areas and has high energy content and nutritional value. Herein, 30 samples of pineapple cv. Vitória were analyzed as a function of the maturation stage (0-5) and their physico-chemical parameters monitored. In addition, negative-ion mode electrospray ionization mass spectrometry [ESI(-)FT-ICR MS] was used to identify and semi-quantify primary and secondary metabolites present in the crude and phenolic extracts of pineapple, respectively. Physico-chemical tests show an increase in the total soluble solids (TSS) values and in the TSS/total titratable acidity ratio as a function of the maturity stage, where a maximum value was observed in stage 3 (¾ of the fruit is yellow, which corresponds to the color of the fruit peel). ESI(-)FT-ICR MS analysis for crude extracts showed the presence mainly of sugars as primary metabolites present in deprotonated molecule form ([M - H] - and [2 M - H] - ions) whereas, for phenolic fractions, 11 compounds were detected, being the most abundant in the third stage of maturation. This behavior was confirmed by quantitative analysis of total polyphenols. ESI-FT-ICR MS was efficient in identifying primary (carbohydrates and organic acids) and secondary metabolites (13 phenolic compounds) presents in the crude and phenolic extract of the samples, respectively. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  17. Standard test methods for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of nuclear-grade plutonium nitrate solutions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 These test methods cover procedures for the chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of nuclear-grade plutonium nitrate solutions to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Plutonium by Controlled-Potential Coulometry Plutonium by Amperometric Titration with Iron(II) Plutonium by Diode Array Spectrophotometry Free Acid by Titration in an Oxalate Solution 8 to 15 Free Acid by Iodate Precipitation-Potentiometric Titration Test Method 16 to 22 Uranium by Arsenazo I Spectrophotometric Test Method 23 to 33 Thorium by Thorin Spectrophotometric Test Method 34 to 42 Iron by 1,10-Phenanthroline Spectrophotometric Test Method 43 to 50 Impurities by ICP-AES Chloride by Thiocyanate Spectrophotometric Test Method 51 to 58 Fluoride by Distillation-Spectrophotometric Test Method 59 to 66 Sulfate by Barium Sulfate Turbidimetric Test Method 67 to 74 Isotopic Composition by Mass Spectrom...

  18. Analysis of acylcarnitines as their N-demethylated ester derivatives by gas chromatography-chemical ionization mass spectrometry.

    Science.gov (United States)

    Huang, Z H; Gage, D A; Bieber, L L; Sweeley, C C

    1991-11-15

    A novel approach to the analysis of acylcarnitines has been developed. It involves a direct esterification using propyl chloroformate in aqueous propanol followed by ion-pair extraction with potassium iodide into chloroform and subsequent on-column N-demethylation of the resulting acylcarnitine propyl ester iodides. The products, acyl N-demethylcarnitine propyl esters, are volatile and are easily analyzed by gas chromatography-chemical ionization mass spectrometry. For medium-chain-length (C4-C12) acylcarnitine standards, detection limits are demonstrated to be well below 1 ng starting material using selected ion monitoring. Well-separated gas chromatographic peaks and structure-specific mass spectra are obtained with samples of synthetic and biological origin. Seven acylcarnitines have been characterized in the urine of a patient suffering from medium-chain acyl-CoA dehydrogenase deficiency.

  19. Recent trends in utilising ionising radiations for nondestructive evaluation of materials (Preprint No. SP-3)

    International Nuclear Information System (INIS)

    Raj, Baldev; Venkatraman, B.

    1988-02-01

    The various NDT techniques based on the use of ionising radiations can be broadly classified into radiography, radiation gaging techniques and analytical techniques. This paper highlights the state of art of these techniques along with their applications. While an effort has been made to cover the major techniques based on ionising radiations, many techniques utilising ionising radiations as xeroradiography, laminography, ionography etc, have not been dealt with due to their restricted applications. (author). 23 refs., 4 figs

  20. Chemical mass transport between fluid fine tailings and the overlying water cover of an oil sands end pit lake

    Science.gov (United States)

    Dompierre, Kathryn A.; Barbour, S. Lee; North, Rebecca L.; Carey, Sean K.; Lindsay, Matthew B. J.

    2017-06-01

    Fluid fine tailings (FFT) are a principal by-product of the bitumen extraction process at oil sands mines. Base Mine Lake (BML)—the first full-scale demonstration oil sands end pit lake (EPL)—contains approximately 1.9 × 108 m3 of FFT stored under a water cover within a decommissioned mine pit. Chemical mass transfer from the FFT to the water cover can occur via two key processes: (1) advection-dispersion driven by tailings settlement; and (2) FFT disturbance due to fluid movement in the water cover. Dissolved chloride (Cl) was used to evaluate the water cover mass balance and to track mass transport within the underlying FFT based on field sampling and numerical modeling. Results indicated that FFT was the dominant Cl source to the water cover and that the FFT is exhibiting a transient advection-dispersion mass transport regime with intermittent disturbance near the FFT-water interface. The advective pore water flux was estimated by the mass balance to be 0.002 m3 m-2 d-1, which represents 0.73 m of FFT settlement per year. However, the FFT pore water Cl concentrations and corresponding mass transport simulations indicated that advection rates and disturbance depths vary between sample locations. The disturbance depth was estimated to vary with location between 0.75 and 0.95 m. This investigation provides valuable insight for assessing the geochemical evolution of the water cover and performance of EPLs as an oil sands reclamation strategy.

  1. Desorption atmospheric pressure photoionization high-resolution mass spectrometry: a complementary approach for the chemical analysis of atmospheric aerosols.

    Science.gov (United States)

    Parshintsev, Jevgeni; Vaikkinen, Anu; Lipponen, Katriina; Vrkoslav, Vladimir; Cvačka, Josef; Kostiainen, Risto; Kotiaho, Tapio; Hartonen, Kari; Riekkola, Marja-Liisa; Kauppila, Tiina J

    2015-07-15

    On-line chemical characterization methods of atmospheric aerosols are essential to increase our understanding of physicochemical processes in the atmosphere, and to study biosphere-atmosphere interactions. Several techniques, including aerosol mass spectrometry, are nowadays available, but they all suffer from some disadvantages. In this research, desorption atmospheric pressure photoionization high-resolution (Orbitrap) mass spectrometry (DAPPI-HRMS) is introduced as a complementary technique for the fast analysis of aerosol chemical composition without the need for sample preparation. Atmospheric aerosols from city air were collected on a filter, desorbed in a DAPPI source with a hot stream of toluene and nitrogen, and ionized using a vacuum ultraviolet lamp at atmospheric pressure. To study the applicability of the technique for ambient aerosol analysis, several samples were collected onto filters and analyzed, with the focus being on selected organic acids. To compare the DAPPI-HRMS data with results obtained by an established method, each filter sample was divided into two equal parts, and the second half of the filter was extracted and analyzed by liquid chromatography/mass spectrometry (LC/MS). The DAPPI results agreed with the measured aerosol particle number. In addition to the targeted acids, the LC/MS and DAPPI-HRMS methods were found to detect different compounds, thus providing complementary information about the aerosol samples. DAPPI-HRMS showed several important oxidation products of terpenes, and numerous compounds were tentatively identified. Thanks to the soft ionization, high mass resolution, fast analysis, simplicity and on-line applicability, the proposed methodology has high potential in the field of atmospheric research. Copyright © 2015 John Wiley & Sons, Ltd.

  2. Plasma flame for mass purification of contaminated air with chemical and biological warfare agents

    International Nuclear Information System (INIS)

    Uhm, Han S.; Shin, Dong H.; Hong, Yong C.

    2006-01-01

    An elimination of airborne simulated chemical and biological warfare agents was carried out by making use of a plasma flame made of atmospheric plasma and a fuel-burning flame, which can purify the interior air of a large volume in isolated spaces such as buildings, public transportation systems, and military vehicles. The plasma flame generator consists of a microwave plasma torch connected in series to a fuel injector and a reaction chamber. For example, a reaction chamber, with the dimensions of a 22 cm diameter and 30 cm length, purifies an airflow rate of 5000 lpm contaminated with toluene (the simulated chemical agent) and soot from a diesel engine (the simulated aerosol for biological agents). Large volumes of purification by the plasma flame will free mankind from the threat of airborne warfare agents. The plasma flame may also effectively purify air that is contaminated with volatile organic compounds, in addition to eliminating soot from diesel engines as an environmental application

  3. Mass transfer rate through liquid membranes: interfacial chemical reactions and diffusion as simultaneous permeability controlling factors

    International Nuclear Information System (INIS)

    Danesi, P.R.; Horwitz, E.P.; Vandegrift, G.F.; Chiarizia, R.

    1981-01-01

    Equations describing the permeability of a liquid membrane to metal cations have been derived taking into account aqueous diffusion, membrane diffusion, and interfacial chemical reactions as simultaneous permeability controlling factors. Diffusion and chemical reactions have been coupled by a simple model analogous to the one previously described by us to represent liquid-liquid extraction kinetics. The derived equations, which make use of experimentally determined interfacial reaction mechanisms, qualitatively fit unexplained literature data regarding Cu 2+ transfer through liquid membranes. Their use to predict and optimize membrane permeability in practical separation processes by setting the appropriate concentration of the membrane carrier [LIX 64 (General Mills), a commercial β-hydroxy-oxime] and the pH of the aqueous copper feed solution is briefly discussed. 4 figures

  4. Neutronics and mass transport in a chemical reactor associated with controlled thermonuclear fusion reactor

    International Nuclear Information System (INIS)

    Dang, V.D.; Steinberg, M.; Lazareth, O.W.; Powell, J.R.

    1976-05-01

    The formation of ozone from oxygen and the dissociation carbon dioxide to carbon monoxide and oxygen is studied in a gamma-neutron chemical process blanket associated with a controlled thermonuclear reactor. Materials used for reactor tube wall will affect the efficiency of the energy absorption by the reactants and consequently the yield of reaction products. Three kinds of materials, aluminum, stainless steel and fiber (Al 2 O 3 )-aluminium are investigated for the tube wall material in the study

  5. Analysis of insect triacylglycerols using liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Kofroňová, Edita; Cvačka, Josef; Jiroš, Pavel; Sýkora, D.; Valterová, Irena

    2009-01-01

    Roč. 111, č. 5 (2009), s. 519-525 ISSN 1438-7697 R&D Projects: GA AV ČR IAA4055403; GA MŠk 2B06007 Institutional research plan: CEZ:AV0Z40550506 Keywords : atmospheric pressure chemical ionization * bumblebees * fat body * NARP-HPLC Subject RIV: CC - Organic Chemistry Impact factor: 1.831, year: 2009

  6. ISOTOPE-DILUTION AMMONIA CHEMICAL-IONIZATION MASS FRAGMENTOGRAPHIC ANALYSIS OF URINARY 3-O-METHYLATED CATECHOLAMINE METABOLITES - RAPID SAMPLE CLEANUP BY DERIVATIZATION AND EXTRACTION OF LYOPHILIZED SAMPLES

    NARCIS (Netherlands)

    KEMA, IP; MEIBORG, G; NAGEL, GT; STOB, GJ; MUSKIET, FAJ

    1993-01-01

    We developed a method for simultaneous quantification of the urinary 3-O-methylated catecholamine metabolites 3-methoxytyramine, normetanephrine and metanephrine by stable isotope-dilution ammonia chemical ionization mass fragmentography. Prepurification of lyophilized samples was done by

  7. Domestic Preparedness Program: Evaluation of the Agilent Gas Chromatograph - Flame Photometric Detector/Mass Selective Detector (GC-FPD/MSD) System Against Chemical Warfare Agents Summary Report

    National Research Council Canada - National Science Library

    Longworth, Terri

    2003-01-01

    This report characterizes the chemical warfare agent (CWA) detection potential of the commercially available Agilent gas chromatograph-flame photometric detector/mass selective detector (GC-FPD/MSD...

  8. Resonant laser mass spectrometry for environmental and industrial chemical trace analysis

    International Nuclear Information System (INIS)

    Boesl, Ulrich; Rink, Joerg; Distelrath, Volker; Pueffel, Peter

    2001-01-01

    A promising new method for pollutant trace analysis is resonant laser mass spectrometry. It combines selectivity, sensitivity, and speed of measurement. In this paper, two examples of application are presented: exhaust analysis of combustion engines and analysis of polycylcic aromatic compounds in soil samples. The sensitivity of small, mobile instruments is discussed as well as alternative laser-based techniques in the case formation of cations by nanosecond lasers is improbable

  9. Chemical analysis of surfaces by resonance ionization mass spectroscopy associated to ionic pulverization

    International Nuclear Information System (INIS)

    Kern, P.

    1995-01-01

    This work shows that if resonance ionization mass spectroscopy was first applied in isotopic separation, it's also an analyzing method adapted to the study of semi-conductor materials and thin foils. We have improved this technic: a neodymium laser coupled with a dye laser, a new argon ions gun, a gallium ions gun and a new collection optic for the secondary ions quadrupole spectrometer to allow quantitative and selective measurements. (S.G.). 84 refs

  10. A High Throughput Ambient Mass Spectrometric Approach to Species Identification and Classification from Chemical Fingerprint Signatures

    Science.gov (United States)

    Musah, Rabi A.; Espinoza, Edgard O.; Cody, Robert B.; Lesiak, Ashton D.; Christensen, Earl D.; Moore, Hannah E.; Maleknia, Simin; Drijfhout, Falko P.

    2015-01-01

    A high throughput method for species identification and classification through chemometric processing of direct analysis in real time (DART) mass spectrometry-derived fingerprint signatures has been developed. The method entails introduction of samples to the open air space between the DART ion source and the mass spectrometer inlet, with the entire observed mass spectral fingerprint subjected to unsupervised hierarchical clustering processing. A range of both polar and non-polar chemotypes are instantaneously detected. The result is identification and species level classification based on the entire DART-MS spectrum. Here, we illustrate how the method can be used to: (1) distinguish between endangered woods regulated by the Convention for the International Trade of Endangered Flora and Fauna (CITES) treaty; (2) assess the origin and by extension the properties of biodiesel feedstocks; (3) determine insect species from analysis of puparial casings; (4) distinguish between psychoactive plants products; and (5) differentiate between Eucalyptus species. An advantage of the hierarchical clustering approach to processing of the DART-MS derived fingerprint is that it shows both similarities and differences between species based on their chemotypes. Furthermore, full knowledge of the identities of the constituents contained within the small molecule profile of analyzed samples is not required. PMID:26156000

  11. Mass Casualty Decontamination in a Chemical or Radiological/ Nuclear Incident: Further Guiding Principles

    Science.gov (United States)

    Carter, Holly; Amlôt, Richard; Williams, Richard; Rubin, G. James; Drury, John

    2016-01-01

    This short report presents a response to an article written by Cibulsky et al. (2016). The paper by Cibulsky et al. presents a useful and timely overview of the evidence surrounding the technical and operational aspects of mass casualty decontamination. It identifies three priority targets for future research, the third of which is how casualties' needs can be met in ways that best support compliance with and effectiveness of casualty decontamination. While further investigation into behavioural, communication and privacy issues during mass decontamination is warranted, there is now a substantial body of research in this area which is not considered in detail in the succinct summary provided by Cibulsky et al. (2016). In this short report, we summarise the available evidence around likely public behaviour during mass decontamination, effective communication strategies, and potential issues resulting from a lack of privacy. Our intention is to help further focus the research needs in this area and highlight topics on which more research is needed. PMID:27790381

  12. Microsynthesis and electron ionization mass spectral studies of O(S)-alkyl N,N-dimethyl alkylphosphono(thiolo)thionoamidates for Chemical Weapons Convention verification.

    Science.gov (United States)

    Saeidian, Hamdollah; Babri, Mehran; Abdoli, Morteza; Sarabadani, Mansour; Ashrafi, Davood; Naseri, Mohammad Taghi

    2012-12-15

    The availability of mass spectra and interpretation skills are essential for unambiguous identification of the Chemical Weapons Convention (CWC)-related chemicals. The O(S)-alkyl N,N-dimethyl alkylphosphono(thiolo)thionoamidates are included in the list of scheduled CWC-related compounds, but there are very few spectra from these compounds in the literature. This paper examines these spectra and their mass spectral fragmentation routes. The title chemicals were prepared through microsynthetic protocols and were analyzed using electron ionization mass spectrometry with gas chromatography as a MS-inlet system. Structures of fragments were confirmed using analysis of fragment ions of deuterated analogs, tandem mass spectrometry and density functional theory (DFT) calculations. Mass spectrometric studies revealed some interesting fragmentation pathways during the ionization process, such as alkene and amine elimination and McLafferty-type rearrangements. The most important fragmentation route of the chemicals is the thiono-thiolo rearrangement. DFT calculations are used to support MS results and to reveal relative preference formation of fragment ions. The retention indices (RIs) of all the studied compounds are also reported. Mass spectra of the synthesized compounds were investigated with the aim to enrich the Organization for the Prohibition of Chemical Weapons (OPCW) Central Analytical Database (OCAD) which may be used for detection and identification of CWC-related chemicals during on-site inspection and/or off-site analysis such as OPCW proficiency tests. Copyright © 2012 John Wiley & Sons, Ltd.

  13. Identification of the chemical constituents of Chinese medicine Yi-Xin-Shu capsule by molecular feature orientated precursor ion selection and tandem mass spectrometry structure elucidation.

    Science.gov (United States)

    Wang, Hong-ping; Chen, Chang; Liu, Yan; Yang, Hong-Jun; Wu, Hong-Wei; Xiao, Hong-Bin

    2015-11-01

    The incomplete identification of the chemical components of traditional Chinese medicinal formula has been one of the bottlenecks in the modernization of traditional Chinese medicine. Tandem mass spectrometry has been widely used for the identification of chemical substances. Current automatic tandem mass spectrometry acquisition, where precursor ions were selected according to their signal intensity, encounters a drawback in chemical substances identification when samples contain many overlapping signals. Compounds in minor or trace amounts could not be identified because most tandem mass spectrometry information was lost. Herein, a molecular feature orientated precursor ion selection and tandem mass spectrometry structure elucidation method for complex Chinese medicine chemical constituent analysis was developed. The precursor ions were selected according to their two-dimensional characteristics of retention times and mass-to-charge ratio ranges from herbal compounds, so that all precursor ions from herbal compounds were included and more minor chemical constituents in Chinese medicine were identified. Compared to the conventional automatic tandem mass spectrometry setups, the approach is novel and can overcome the drawback for chemical substances identification. As an example, 276 compounds from the Chinese Medicine of Yi-Xin-Shu capsule were identified. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Quantitative assessment of chemical artefacts produced by propionylation of histones prior to mass spectrometry analysis.

    Science.gov (United States)

    Soldi, Monica; Cuomo, Alessandro; Bonaldi, Tiziana

    2016-07-01

    Histone PTMs play a crucial role in regulating chromatin structure and function, with impact on gene expression. MS is nowadays widely applied to study histone PTMs systematically. Because histones are rich in arginine and lysine, classical shot-gun approaches based on trypsin digestion are typically not employed for histone modifications mapping. Instead, different protocols of chemical derivatization of lysines in combination with trypsin have been implemented to obtain "Arg-C like" digestion products that are more suitable for LC-MS/MS analysis. Although widespread, these strategies have been recently described to cause various side reactions that result in chemical modifications prone to be misinterpreted as native histone marks. These artefacts can also interfere with the quantification process, causing errors in histone PTMs profiling. The work of Paternoster V. et al. is a quantitative assessment of methyl-esterification and other side reactions occurring on histones after chemical derivatization of lysines with propionic anhydride [Proteomics 2016, 16, 2059-2063]. The authors estimate the effect of different solvents, incubation times, and pH on the extent of these side reactions. The results collected indicate that the replacement of methanol with isopropanol or ACN not only blocks methyl-esterification, but also significantly reduces other undesired unspecific reactions. Carefully titrating the pH after propionic anhydride addition is another way to keep methyl-esterification under control. Overall, the authors describe a set of experimental conditions that allow reducing the generation of various artefacts during histone propionylation. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Nitrogen losses from dairy manure estimated through nitrogen mass balance and chemical markers

    Science.gov (United States)

    Hristov, Alexander N.; Zaman, S.; Vander Pol, M.; Ndegwa, P.; Campbell, L.; Silva, S.

    2009-01-01

    Ammonia is an important air and water pollutant, but the spatial variation in its concentrations presents technical difficulties in accurate determination of ammonia emissions from animal feeding operations. The objectives of this study were to investigate the relationship between ammonia volatilization and ??15N of dairy manure and the feasibility of estimating ammonia losses from a dairy facility using chemical markers. In Exp. 1, the N/P ratio in manure decreased by 30% in 14 d as cumulative ammonia losses increased exponentially. Delta 15N of manure increased throughout the course of the experiment and ??15N of emitted ammonia increased (p rights reserved.

  16. Conductivity of graphene in the framework of Dirac model: Interplay between nonzero mass gap and chemical potential

    Science.gov (United States)

    Klimchitskaya, G. L.; Mostepanenko, V. M.; Petrov, V. M.

    2017-12-01

    The complete theory of electrical conductivity of graphene at arbitrary temperature is developed with taking into account mass-gap parameter and chemical potential. Both the in-plane and out-of-plane conductivities of graphene are expressed via the components of the polarization tensor in (2+1)-dimensional space-time analytically continued to the real frequency axis. Simple analytic expressions for both the real and imaginary parts of the conductivity of graphene are obtained at zero and nonzero temperature. They demonstrate an interesting interplay depending on the values of mass gap and chemical potential. In the local limit, several results obtained earlier using various approximate and phenomenological approaches are reproduced, refined, and generalized. The numerical computations of both the real and imaginary parts of the conductivity of graphene are performed to illustrate the obtained results. The analytic expressions for the conductivity of graphene obtained in this paper can serve as a guide in the comparison between different theoretical approaches and between experiment and theory.

  17. Multivariate Statistical Analysis of Orthogonal Mass Spectral Data for the Identification of Chemical Attribution Signatures of 3-Methylfentanyl

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, B. P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Valdez, C. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); DeHope, A. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Spackman, P. E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Sanner, R. D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Martinez, H. P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Williams, A. M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-11-28

    Critical to many modern forensic investigations is the chemical attribution of the origin of an illegal drug. This process greatly relies on identification of compounds indicative of its clandestine or commercial production. The results of these studies can yield detailed information on method of manufacture, sophistication of the synthesis operation, starting material source, and final product. In the present work, chemical attribution signatures (CAS) associated with the synthesis of the analgesic 3- methylfentanyl, N-(3-methyl-1-phenethylpiperidin-4-yl)-N-phenylpropanamide, were investigated. Six synthesis methods were studied in an effort to identify and classify route-specific signatures. These methods were chosen to minimize the use of scheduled precursors, complicated laboratory equipment, number of overall steps, and demanding reaction conditions. Using gas and liquid chromatographies combined with mass spectrometric methods (GC-QTOF and LC-QTOF) in conjunction with inductivelycoupled plasma mass spectrometry (ICP-MS), over 240 distinct compounds and elements were monitored. As seen in our previous work with CAS of fentanyl synthesis the complexity of the resultant data matrix necessitated the use of multivariate statistical analysis. Using partial least squares discriminant analysis (PLS-DA), 62 statistically significant, route-specific CAS were identified. Statistical classification models using a variety of machine learning techniques were then developed with the ability to predict the method of 3-methylfentanyl synthesis from three blind crude samples generated by synthetic chemists without prior experience with these methods.

  18. Mass spectrometric analysis of lithium

    International Nuclear Information System (INIS)

    Chitambar, S.A.; Kavimandan, V.D.; Aggarwal, S.K.; Ramasubramanian, P.A.; Shah, P.M.; Almoula, A.I.; Acharya, S.N.; Parab, A.R.; Jain, H.C.; Mathews, C.K.; Ramaniah, M.V.

    1978-01-01

    The details of investigations carried out on the isotopic analysis of lithium using surface ionisation mass spectrometry are presented. Various parameters affecting the precision in isotopic analysis of lithium are discussed. A precision of 1% is achieved in the relative isotope abundance measurement. (author)

  19. Fitness of equipment used for medical exposures to ionising radiation

    International Nuclear Information System (INIS)

    1998-01-01

    The advice in this guidance note is aimed at employers in control of equipment used for medical exposures to ionising radiation and ancillary equipment. This includes NHS trusts, health authorities or boards, private hospitals, clinics, surgeries, medical X-ray facilities in industry, dentists and chiropractors. The guidance should also be useful to radiation protection advisers appointed by such employers. The guidance provides advice on the requirements of regulation 33 of the Ionising Radiations Regulations 1985 (IRR85). In particular, it covers: (a) the selection, installation, maintenance, calibration and replacement of equipment to ensure that it is capable of restricting, so far as reasonably practicable, the medical exposure of any person to the extent that this is compatible with the intended diagnostic or therapeutic purpose; (b) recommended procedures for the definitive calibration of radiotherapy treatment; and (c) the need to investigate incidents involving a malfunction or defect in any 'radiation equipment' which result in medical exposures much greater than intended and to notify the Health and Safety Executive (HSE). 'Medical exposure' is defined in IRR85 as exposure of a person to ionising radiation for the purpose of his or her medical or dental examination or treatment which is conducted under the direction of a suitably qualified person and includes any such examination or treatment conducted for the purposes of research. For convenience, people undergoing medical exposure will be referred to as 'patients' in this guidance. Nothing in this publication is intended to indicate whether or not patients should be informed of any incident resulting from malfunction or defect in equipment used for medical exposure and the possible consequences of that exposure. As stated above, this guidance concerns medical exposures much greater than intended and although exposures much lower than intended can also have serious consequences, the incident would not

  20. Ionising radiation safety training in the Australian defence organisation (ADO)

    International Nuclear Information System (INIS)

    Jenks, G.J.; O'Donovan, E.J.B.; Wood, W.B.

    1996-01-01

    Full text: Training personnel in ionising radiation safety within the Australian Defence Organisation (ADO) requires addressing some unique features of an organisation employing both military and civilian personnel. Activities may include those of a civil nature (such as industrial and medical radiography), specific military requirements (for training and emergency response) and scientific research and development. Some personnel may be assigned to full-time duties associated with radiation, while others may be designated as radiation protection officers in remote units with few duties to perform in this role. A further complication is that most military personnel are subjected to postings at regular intervals. The ADO's Directorate of Defence Occupational Health and Safety has established an Ionising Radiation Safety Subcommittee to monitor not only the adequacy of the internal Ionising Radiation Safety Manual but also the training requirements. A training course, responding to these requirements, has been developed to emphasise: basic radiation theory and protection; operation of radiation monitors available in the ADO; an understanding of the Safety Manual; day-to-day radiation safety in units and establishments; and appropriate responses to radiation accidents and emergencies. In addition, students are briefed on a limited number of peripheral topics and participate in some site visits. Currently, two Courses are held annually, each with about twenty students. Most of the material is presented by ADO personnel with external contractor support. The three Courses held to date have proved sufficiently successful, both for the students and the ADO generally, to seek national accreditation through the Australian National Training Authority and, as a first step, competency standards have been identified

  1. Effect of mass loss by stellar wind on the chemical enrichment of the galaxy

    Energy Technology Data Exchange (ETDEWEB)

    Chiosi, C [Padua Univ. (Italy). Istituto di Astronomia

    1979-01-01

    The rate of production of heavy elements is rediscussed using the models of Arnett (1978) for late stage nucleosynthesis in massive stars, the M(M,) relationship of Chiosi et al. (1978b) for losing mass models in the core H and He-Burning phases, and the stellar birth rate of Miller and Scalo (1978). Contrary to that found by Wheeler et al (1978), we do not encounter the difficulty of heavy element overproduction. The explosive nucleosynthesis from massive stars is still compatible with the observed abundance distribution of the solar system, and a stellar birth rate decreasing over the history of the galactic disk.

  2. The effect of mass loss by stellar wind on the chemical enrichment of the galaxy

    International Nuclear Information System (INIS)

    Chiosi, C.

    1979-01-01

    The rate of production of heavy elements is rediscussed using the models of Arnett (1978) for late stage nucleosynthesis in massive stars, the M(M,) relationship of Chiosi et al. (1978b) for losing mass models in the core H and He-Burning phases, and the stellar birth rate of Miller and Scalo (1978). Contrary to that found by Wheeler et al (1978), we do not encounter the difficulty of heavy element overproduction. The explosive nucleosynthesis from massive stars is still compatible with the observed abundance distribution of the solar system, and a stellar birth rate decreasing over the history of the galactic disk. (orig.)

  3. Ionization of anisothermal plasmas. Ionisation des plasmas polythermes

    Energy Technology Data Exchange (ETDEWEB)

    Dennery, F.M.

    1994-01-01

    During this last mid-century, only the temperature of electrons has been involved in the Saha's mass action law, whatever be the other ionic and neutral ones in any isothermal or anisothermal plasma. In order to set aside this underlying paradox in the case of argon ionization, it is necessary to improve this equation of partial equilibrium after having defined: - the basic Gibbs-Duhem's relations for such a polythermal mixture, - the inhomogeneous equilibrium issued from chemical reactions according to Le Chatelier's principle. (author). 3 refs.

  4. Beam Dynamics in a Muon Ionisation Cooling Channel

    International Nuclear Information System (INIS)

    Rogers, Chris

    2008-01-01

    The Neutrino Factory has been proposed as a facility to provide an intense source of neutrinos suitable for the measurement of neutrino oscillation parameters and a possible CP violating phase to unprecedented precision. In the Neutrino Factory, neutrinos are produced by the decay of a muon beam with 20-50 GeV per muon. Initially, the muon beam occupies a large volume in phase space, which must be reduced before the beam can be accelerated. The proposed method to achieve this is to use a solenoidal ionisation colling channel.

  5. Ionising radiations - an ecological problem of indoor architectural environment

    International Nuclear Information System (INIS)

    Djukanovic, M.

    1995-01-01

    Architectural buildings are assessed not only for their esthetic characteristics but human settlements are considered now, as ecosystems and homes and flats as habitats (bio tops). Because of that healthy environment and influences of nonpolluting factors are of a great importance. The use of appropriate building materials harmless to health, contrary to the use of those that emit radon with its ionising effects and consequent health hazards, is of a great importance, too. The purpose of this paper is to emphasize the importance of investigation of building materials before their use, as well as the importance of quality control of soil where the construction is planned. (author)

  6. On analytical fits for electron impact ionisation cross sections

    International Nuclear Information System (INIS)

    Godunov, A.L.; Ivanov, P.B.

    1999-01-01

    The problem of providing accurate recommended analytical fits for electron impact ionisation cross sections is discussed, and a number of approaches are considered on the sample case of neon and its ions. The previously known fits are being reassessed using complete experimental and theoretical data, with the preference for experiment, to avoid systematic shifts introduced by the present calculation methods. The feasibility of the standard BELI formula is investigated in detail, and a number of other analytical expressions is suggested, approximating single-ionization cross sections in the whole range of energies. The factors influencing the accuracy of the fits and the physical meaning of the parameters obtained are discussed. (orig.)

  7. The Radman Guide to the Ionising Radiations Regulations 1985

    International Nuclear Information System (INIS)

    Hughes, D.

    1986-01-01

    The guidance given in the handbook is of general nature for the assistance of senior managers and administrators (rather than scientific or technical staff), involved in or responsible for work with ionising radiations. The subject is dealt with under the following headings: 1) Digest of the Regulations. 2) Application of Regulations (division of responsibility between employer, employee, supervisors, medical personnel etc., role of the Health and Safety Executive.) 3) Designation of work areas and persons 4) Radiation Protection Supervisors and Local Rules 5) Hazard assessments and contingency plans 6) Notifications and Record Keeping 7) Routines in source control. (UK)

  8. Injuries to embryo and foetus from ionising radiation

    International Nuclear Information System (INIS)

    Devik, F.

    1980-01-01

    A brief review is given of experimental and clinical evidence for tetatological effects of ionising radiation, against the background of general teratology. International and national recommendations and regulations for the protection of the conceptus are quoted. As to interruption of a pregnancy following an unintended exposure, it is pointed out that much of the present evidence points to a dose in the order of 0.1Gy (10 rads) as a dose which may be considered as a practical threshold for the induction of congenital defects. (Auth.)

  9. ALARA - the contribution of the proposed new ionising radiations regulations

    International Nuclear Information System (INIS)

    Young, T.O.

    1982-01-01

    This paper describes the proposed regulatory requirements and appropriate guidance contained in the approved code of practice on ionising radiations which are designed to support and help reach the objective of keeping radiation doses as low as reasonably achievable. This is discussed against the background of factory legislation, and the way in which the form of the proposed legislation handles this topic is illustrated. The measures required by the proposed legislation are reviewed, both as direct measures designed to create a climate of dose reduction, and as general measures designed to achieve the same end by means of a wide range of requirements. (author)

  10. On the critical current of ionisation waves in gas discharges

    International Nuclear Information System (INIS)

    Sato, M.

    1982-01-01

    Measurement methods for determining the critical current of ionisation waves in gas discharge tubes are examined in detail. The conventional visual method which finds the current at which the waves disappear is erroneous since the criterion, 'observable', depends on the observing conditions. In the rigorous method it is defined as a current at which the linear growth rate of waves is zero. For the measured upper critical (Pupp) current of argon gas, close agreement is found between the results of other workers and those of the present author over a wide range of pressure-radius product 0.3 approximately equal to 60 Torr cm. (author)

  11. Use of ionising radiation for food processing applications

    International Nuclear Information System (INIS)

    Ninjoor, V.

    1989-01-01

    Food irradiation is a recently developed technique used to sterilize and preserve food. Food products are exposed to ionising radiations such as X-rays, gamma rays or high energy electrons which destroy food borne pathogens and parasites and inhibit sprouting. Shelf life of food is extended. The following aspects of radiation processing of food are discussed in the monograph: radiation sources, choice of dose for specific results, safety and nutritional quality of radiation processed food, international status of acceptance of food irradiation, and cost. (M.G.B.). 6 tabs

  12. The K-shell ionisation of atoms by relativistic protons

    International Nuclear Information System (INIS)

    Davidovic, D.M.; Moiseiwitsch, B.L.; Norrington, P.H.

    1978-01-01

    The K-shell ionisation of atoms by protons travelling with relativistic velocities is investigated using an extension of the first-order time-dependent perturbation-theory treatment of Moeller (Ann. Phys. Lpz.; 14:531 (1932)), taking Dirac plane waves for the description of the incident and scattered protons and the Darwin approximation for the relativistic wavefunctions of the K-shell atomic electrons and the ejected electron. The differential cross sections and total cross sections are calculated. Results are compared with those of earlier workers. (author)

  13. The L1-shell ionisation of atoms by relativistic particles

    International Nuclear Information System (INIS)

    Moiseiwitsch, B.L.; Norrington, P.H.

    1979-01-01

    An expression for the L 1 -shell ionisation cross sections of atoms by high-energy particles has been derived using the relativistic plane-wave Born approximation. The incident and scattered particles are described by Dirac plane waves while Darwin hydrogenic wavefunctions are used for the atomic electrons. A comparison is made with experimental total cross sections for incident electrons in the energy range 1-2 MeV. The agreement is a considerable improvement on that obtained using the non-relativistic planewave Born approximation. (author)

  14. Setting up and performance of a laser enhanced ionisation spectrometer

    International Nuclear Information System (INIS)

    Chandola, L.C.; Khanna, P.P.; Razvi, M.A.N.

    1990-01-01

    A laser enhanced ionisation (LEI) spectrometer has been successfuly set up around an excimer laser pumped dye laser. The performance of the spectrometer has been tested by analysing sodium in water solutions. A straight line working curve has been obtained in the concentration range of 1-1000 ng/ml of Na. The effect of parameters like laser power, ion collector electrode voltage and the load resistance on LEI signals has been investigated. The spectrometer is useful not only for analytical purposes but also for laser spectroscopic studies of species formed in flames, study of phenomenon of combustion etc. (author). 1 tab ., 10 figs., 5 refs

  15. Chemical or Biological Terrorist Attacks: An Analysis of the Preparedness of Hospitals for Managing Victims Affected by Chemical or Biological Weapons of Mass Destruction

    Science.gov (United States)

    Bennett, Russell L.

    2006-01-01

    The possibility of a terrorist attack employing the use of chemical or biological weapons of mass destruction (WMD) on American soil is no longer an empty threat, it has become a reality. A WMD is defined as any weapon with the capacity to inflict death and destruction on such a massive scale that its very presence in the hands of hostile forces is a grievous threat. Events of the past few years including the bombing of the World Trade Center in 1993, the Murrah Federal Building in Oklahoma City in 1995 and the use of planes as guided missiles directed into the Pentagon and New York’s Twin Towers in 2001 (9/11) and the tragic incidents involving twenty-three people who were infected and five who died as a result of contact with anthrax-laced mail in the Fall of 2001, have well established that the United States can be attacked by both domestic and international terrorists without warning or provocation. In light of these actions, hospitals have been working vigorously to ensure that they would be “ready” in the event of another terrorist attack to provide appropriate medical care to victims. However, according to a recent United States General Accounting Office (GAO) nationwide survey, our nation’s hospitals still are not prepared to manage mass causalities resulting from chemical or biological WMD. Therefore, there is a clear need for information about current hospital preparedness in order to provide a foundation for systematic planning and broader discussions about relative cost, probable effectiveness, environmental impact and overall societal priorities. Hence, the aim of this research was to examine the current preparedness of hospitals in the State of Mississippi to manage victims of terrorist attacks involving chemical or biological WMD. All acute care hospitals in the State were selected for inclusion in this study. Both quantitative and qualitative methods were utilized for data collection and analysis. Six hypotheses were tested. Using a

  16. Chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of nuclear-grade uranyl nitrate solutions

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    The standard covers analytical procedures to determine compliance of nuclear-grade uranyl nitrate solution to specifications. The following methods are described in detail: uranium by ferrous sulfate reduction-potassium dichromate titrimetry and by ignition gravimetry; specific gravity by pycnometry; free acid by oxalate complexation; thorium by the Arsenazo(III) (photometric) method; chromium by the diphenylcarbazide (photometric) method; molybdenum by the thiocyanate (photometric) method; halogens separation by steam distillation; fluorine by specific ion electrode; halogen distillate analysis: chloride, bromide and iodide by amperometric microtitrimetry; bromine by the fluorescein (photometric) method; sulfate sulfur by (photometric) turbidimetry; phosphorus by the molybdenum blue (photometric) method; silicon by the molybdenum blue (photometric) method; carbon by persulfate oxidation-acid titrimetry; nonvolatile impurities by spectrography; volatile impurities by rotating-disk spark spectrography; boron by emission spectrography; impurity elements by spark source mass spectrography; isotopic composition by multiple filament surface-ionization mass spectrometry; uranium-232 by alpha spectrometry; total alpha activity by direct alpha counting; fission product activity by beta and gamma counting; entrained organic matter by infrared spectrophotometry

  17. Standard methods for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of uranium hexafluoride

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    All methods described for subsampling and analysis of UF 6 are in routine use at United States Atomic Energy Commission installations. A gravimetric method is included for U and titrimetric methods, for Cl 2 and U. Mass spectrometric methods are given for both double and single standard procedures for U-isotopic content and for semiquantitative determination of hydrocarbons, chlorocarbons, and partially substituted halohydrocarbons. Spectroscopic methods are described for 232 U, fission products, Pu, and Np. In some instances an ion exchange- or extraction-separation is specified prior to the spectroscopic determination. Mass spectroscopic procedures for 31 trace elements are included, as are spectrophotometric methods for Br 2 , Si, P, Ti, V, W, Th, and Mo. Following a preliminary separation for some elements, emission spectroscopic procedures are described for B, Si, Ru, Hf, Mo, Nb, Ta, Ti, W, Zr, V, Th, rare earths, and other elements. Procedures for the determination of Sb, Ru, Al, Cd, Co, Ca, Cr, Fe, Pb, Mg, Mn, Ni, K, Na, and Zn by atomic absorption methods are included. The preparation of high-purity U 3 O 8 by the hydrolysis of UF 6 to UO 2 F 2 which upon drying and pyrohydrolysis yields U 3 O 8 is described

  18. Identification of volatile and semivolatile compounds in chemical ionization GC-MS using a mass-to-structure (MTS) Search Engine with integral isotope pattern ranking.

    Science.gov (United States)

    Liao, Wenta; Draper, William M

    2013-02-21

    The mass-to-structure or MTS Search Engine is an Access 2010 database containing theoretical molecular mass information for 19,438 compounds assembled from common sources such as the Merck Index, pesticide and pharmaceutical compilations, and chemical catalogues. This database, which contains no experimental mass spectral data, was developed as an aid to identification of compounds in atmospheric pressure ionization (API)-LC-MS. This paper describes a powerful upgrade to this database, a fully integrated utility for filtering or ranking candidates based on isotope ratios and patterns. The new MTS Search Engine is applied here to the identification of volatile and semivolatile compounds including pesticides, nitrosoamines and other pollutants. Methane and isobutane chemical ionization (CI) GC-MS spectra were obtained from unit mass resolution mass spectrometers to determine MH(+) masses and isotope ratios. Isotopes were measured accurately with errors of Search Engine and details performance testing with over 50 model compounds.

  19. Analysis of polycyclic aromatic hydrocarbons using desorption atmospheric pressure chemical ionization coupled to a portable mass spectrometer.

    Science.gov (United States)

    Jjunju, Fred P M; Maher, Simon; Li, Anyin; Badu-Tawiah, Abraham K; Taylor, Stephen; Cooks, R Graham

    2015-02-01

    Desorption atmospheric pressure chemical ionization (DAPCI) is implemented on a portable mass spectrometer and applied to the direct detection of polycyclic aromatic hydrocarbons (PAHs) and alkyl substituted benzenes. The presence of these compounds in the environment poses a significant threat to the health of both humans and wildlife because of their carcinogenic, toxic, and mutagenic properties. As such, instant detection outside of the laboratory is of particular importance to allow in-situ measurement at the source. Using a rapid, high throughput, miniature, handheld mass spectrometer, several alkyl substituted benzenes and PAHs (i.e., 1,2,3,5-tetramethylbenzene, pentamethylbenzene, hexamethylbenzene, fluoranthene, anthracene, benzo[k]fluoranthene, dibenz[a,h]anthracene, acenaphthene, indeno[1,2,3-c,d]pyrene, 9-ethylfluorene, and 1-benzyl-3-methyl-naphthalene) were identified and characterized using tandem mass spectrometry (MS/MS) from ambient surfaces, in the open air. This method can provide almost instantaneous information while minimizing sample preparation, which is advantageous in terms of both cost and simplicity of analysis. This MS-based technique is applicable to a wide range of environmental organic molecules.

  20. [Determination of naphthenic acids in distillates of crude oil by gas chromatography/chemical ionization-mass spectrometry].

    Science.gov (United States)

    Lü, Zhenbo; Tian, Songbai; Zhai, Yuchun; Sun, Yanwei; Zhuang, Lihong

    2004-05-01

    The petroleum carboxylic acids in 200-420 degrees C distillate of crude oil were separated by the extraction with column chromatography on an anion exchange resin. The effect of the composition and structure of naphthenic acids on separation were studied by the infra-red (IR) spectroscopic techniques. Naphthenic acids and iso-butane reagent gas were introduced into the ion source for chemical ionization, in which the ions represented by [M + C4H9]+ were used to calculate the relative molecular mass for each acid. Based on the mass spectra of pure fatty and naphthenic acids, in combination with the z-series formula CnH(2n + z)O2, the naphthenic acids can be classified into fatty, mono-, bi- ... hexa-cyclic types. The results indicated that the relative molecular mass range of naphthenic acids in this distillates was 170-510, and the carbon number range was C10-C35. The contents of bi-cyclic and tri-cyclic naphthenic acids were higher than others.

  1. An analytical platform for mass spectrometry-based identification and chemical analysis of RNA in ribonucleoprotein complexes.

    Science.gov (United States)

    Taoka, Masato; Yamauchi, Yoshio; Nobe, Yuko; Masaki, Shunpei; Nakayama, Hiroshi; Ishikawa, Hideaki; Takahashi, Nobuhiro; Isobe, Toshiaki

    2009-11-01

    We describe here a mass spectrometry (MS)-based analytical platform of RNA, which combines direct nano-flow reversed-phase liquid chromatography (RPLC) on a spray tip column and a high-resolution LTQ-Orbitrap mass spectrometer. Operating RPLC under a very low flow rate with volatile solvents and MS in the negative mode, we could estimate highly accurate mass values sufficient to predict the nucleotide composition of a approximately 21-nucleotide small interfering RNA, detect post-transcriptional modifications in yeast tRNA, and perform collision-induced dissociation/tandem MS-based structural analysis of nucleolytic fragments of RNA at a sub-femtomole level. Importantly, the method allowed the identification and chemical analysis of small RNAs in ribonucleoprotein (RNP) complex, such as the pre-spliceosomal RNP complex, which was pulled down from cultured cells with a tagged protein cofactor as bait. We have recently developed a unique genome-oriented database search engine, Ariadne, which allows tandem MS-based identification of RNAs in biological samples. Thus, the method presented here has broad potential for automated analysis of RNA; it complements conventional molecular biology-based techniques and is particularly suited for simultaneous analysis of the composition, structure, interaction, and dynamics of RNA and protein components in various cellular RNP complexes.

  2. A new processing scheme for ultra-high resolution direct infusion mass spectrometry data

    Science.gov (United States)

    Zielinski, Arthur T.; Kourtchev, Ivan; Bortolini, Claudio; Fuller, Stephen J.; Giorio, Chiara; Popoola, Olalekan A. M.; Bogialli, Sara; Tapparo, Andrea; Jones, Roderic L.; Kalberer, Markus

    2018-04-01

    High resolution, high accuracy mass spectrometry is widely used to characterise environmental or biological samples with highly complex composition enabling the identification of chemical composition of often unknown compounds. Despite instrumental advancements, the accurate molecular assignment of compounds acquired in high resolution mass spectra remains time consuming and requires automated algorithms, especially for samples covering a wide mass range and large numbers of compounds. A new processing scheme is introduced implementing filtering methods based on element assignment, instrumental error, and blank subtraction. Optional post-processing incorporates common ion selection across replicate measurements and shoulder ion removal. The scheme allows both positive and negative direct infusion electrospray ionisation (ESI) and atmospheric pressure photoionisation (APPI) acquisition with the same programs. An example application to atmospheric organic aerosol samples using an Orbitrap mass spectrometer is reported for both ionisation techniques resulting in final spectra with 0.8% and 8.4% of the peaks retained from the raw spectra for APPI positive and ESI negative acquisition, respectively.

  3. Chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of nuclear-grade plutonium nitrate solutions

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    These analytical procedures are designed to show whether a given material meets the purchaser's specifications as to plutonium content, effective fissile content, and impurity content. The following procedures are described in detail: plutonium by controlled-potential coulometry; plutonium by amperometric titration with iron(II); free acid by titration in an oxalate solution; free acid by iodate precipitation-potentiometric titration method; uranium by Arsenazo I spectrophotometric method; thorium by thorin spectrophotometric method; iron by 1,10-phenanthroline spectrophotometric method; chloride by thiocyanate spectrophotometric method; fluoride by distillation-spectrophotometric method; sulfate by barium sulfate turbidimetric method; isotopic composition by mass spectrometry; americium-241 by extraction and gamma counting; americium-241 by gamma counting; gamma-emitting fission products, uranium, and thorium by gamma-ray spectroscopy; rare earths by copper spark spectrochemical method; tungsten, niobium (columbium), and tantalum by spectrochemical method; simple preparation by spectrographic analysis for general impurities

  4. Glow discharge mass spectrometry study of chemical impurities diffusion in zirconium oxide layers

    International Nuclear Information System (INIS)

    Actis-Dato, L.O.

    2000-02-01

    In the Pressurised Water Reactors (PWR) the primary cooling system is water at 350 deg C and 16 Mpa. In these extreme conditions the corrosion of the out-of-pile components of the reactor and in particular of the Zircaloy cladding containing the nuclear fuel pellets is accelerated. The formation of a growing oxide layer is observed on the elements of the nuclear reactor core. When the thickness of the oxide layer reaches a critical value, problems like structural malfunction and material failure can occur. At this stage the danger of the release of radioactivity in the coolant becomes effective. In this work a glow discharge mass spectrometer is used to study the diffusion of impurities like lithium, zinc and boron in oxide layers growing on Zircaloy samples. After a brief description of the different technique used the preparation and analysis of Zircaloy samples on which oxide layers of different thickness have been produced will be described. The analysis of these samples will allow the determination and evaluation the depth profiles of the impurities absorbed by the oxide. The analysis of the shape of the crater produced during the mass spectrometric analysis will give additional informations on the quality of the results obtained. The technique developed will finally be applied to the study of samples produced during reactor operation under real irradiation conditions. The results obtained show a lithium intake in the oxide layer and confirm the beneficial effect on the corrosion produced by boron. The influence of zinc on the corrosion behaviour of Zircaloy has not been established. The technique developed has also shown interesting capabilities concerning the analysis of irradiated samples. (author)

  5. Biological monitors for low levels of ionising radiation

    International Nuclear Information System (INIS)

    Mohankumar, M.N.; Jeevanram, R.K.

    1995-01-01

    The biological effects of high doses of ionising radiation are well understood and the methods of measurement of these doses well established. However the effects due to extremely low doses remain by and large uncertain. This is because of the fact that at such low doses no gross symptoms are seen. In fact, at these levels the occurrence of double strand breaks leading to the formation of chromosomal aberrations like dicentrics is rare and chances of mutation due to base damage are negligible. Hence neither chromosomal aberration studies nor mutational assays are useful for detecting doses of the order of a few milligray. Results of exhaustive work done by various laboratories indicate that below 20 mGy the chromosomal aberration technique based on scoring of dicentrics cannot distinguish between a linear or a threshold model. However indirect methods like unscheduled DNA synthesis (UDS) and sister chromatid exchanges (SCEs) appear to be promising for the detection of radiation exposures due to low levels of radiation. This report reviews the available literature on the biological effects of low levels of ionising radiation and highlights the merits and demerits of the various methods employed in the measurement of UDS and SCE. The phenomenon of radio-adaptive response (RAR) and its relation to DNA repair is also discussed. (author)

  6. Biological monitors for low levels of ionising radiation

    Energy Technology Data Exchange (ETDEWEB)

    Mohankumar, M N; Jeevanram, R K [Safety Research and Health Physics Group, Indira Gandhi Centre for Atomic Research, Kalpakkam (India)

    1996-12-31

    The biological effects of high doses of ionising radiation are well understood and the methods of measurement of these doses well established. However the effects due to extremely low doses remain by and large uncertain. This is because of the fact that at such low doses no gross symptoms are seen. In fact, at these levels the occurrence of double strand breaks leading to the formation of chromosomal aberrations like dicentrics is rare and chances of mutation due to base damage are negligible. Hence neither chromosomal aberration studies nor mutational assays are useful for detecting doses of the order of a few milligray. Results of exhaustive work done by various laboratories indicate that below 20 mGy the chromosomal aberration technique based on scoring of dicentrics cannot distinguish between a linear or a threshold model. However indirect methods like unscheduled DNA synthesis (UDS) and sister chromatid exchanges (SCEs) appear to be promising for the detection of radiation exposures due to low levels of radiation. This report reviews the available literature on the biological effects of low levels of ionising radiation and highlights the merits and demerits of the various methods employed in the measurement of UDS and SCE. The phenomenon of radio-adaptive response (RAR) and its relation to DNA repair is also discussed. (author). 98 refs., 11 figs., 4 tabs.

  7. Investigation of damage mechanism by ionising radiation on biomolecules

    International Nuclear Information System (INIS)

    Lau How Mooi

    1996-01-01

    Occupational radiation hazard is a very controversial subject. Effects from high radiation doses are well known from past experiences. However, hazard from low doses is still a subject that is hotly debated upon until now. The occupational dosimetry used now is based on a macroscopic scale. Lately, microdosimetry is fast gaining recognition as a more superior way of measuring hazard. More importantly, scientists are researching the basic damage mechanism that leads to biological effects by ionising radiation. In this report, a simulation study of the basic damage mechanism is discussed . This simulation is based upon Monte Carlo calculations and using polyuridylic acid (Poly-U) as the DNA model This simulation tries to relate the physics and chemistry of interactions of ionising radiation with biomolecules. The computer codes used in this simulation, OREC and RADLYS were created by Hamm et al. (1983) in Oak Ridge National Laboratory. The biological endpoints in this simulation are the strand break and base release of the DNA, which is the precursor of all biological effects. These results are compared with model studies that had been done experimentally to check the validity of this simulation. The G-values of strand break and base release from this simulation were -2.35 and 2.75 and compared well with results from irradiation experiments by von Sonntag (I 98 7) from Max Plank's Institute, Germany

  8. Documentation of Occupational Accidents and Diseases caused by Ionising Radiation

    International Nuclear Information System (INIS)

    Fehringer, F.; Seitz, G.

    2004-01-01

    . One of the major goals of the institutions for statutory accident insurance is the prevention of occupational diseases. To perform a successful prevention work it is necessary not only to count the number of accidents or diseases in the various working fields but to look for details of the conditions of work and the human response to those conditions. The institutions for statutory accident insurance have engaged the institution for statutory accident insurance in the precision engineering and electrical industry to carry out documentation, in form of a data bank, for all cases of occupational diseases which could be caused by ionising radiation. Those are not only the cases which are accepted as occupational disease but also the cases where a suspicion of an occupational disease is announced but finally rejected. At the moment about 1700 cases are included in the data bank. For preserving the anonymity information to name and residence are deleted. Various data to one single case are linked by a case-specific key-number. Information to occupation and field of working, to details of a possible exposure to ionising radiation like kind of radiation, time and duration of radiation, exposure of the whole body or of parts of the body and whole body or organ doses are collected. Additional information refers to medical aspects like diagnosis and date of diagnosis. (Author)

  9. Use of voltammetry for in vitro equilibrium and transport studies of ionisable drugs

    Directory of Open Access Journals (Sweden)

    Matej Velicky

    2014-09-01

    Full Text Available In this review, we will briefly outline the voltammetric investigations of the transfer of ionisable drugs at the interface between two immiscible electrolyte solutions. The voltammetric techniques enable the determination of some key in vitro properties of ionisable drugs, including partition coefficient, diffusion coefficient and membrane permeability. Some successful applications will be highlighted, together with the background methodologies.

  10. Application of R-Matrix with Time-dependence Theory to Double Ionisation Using a 2-electron Outer Region

    International Nuclear Information System (INIS)

    Wragg, Jack; Parker, J S; Van der Hart, H W

    2015-01-01

    R-Matrix with Time-dependence (RMT) theory has been extended to cover double-ionisation processes. An application to photoionisation of He is demonstrated, with an emphasis on double-ionisation cross sections. (paper)

  11. Chemical preparation of biological materials for accurate chromium determination by isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Dunstan, L.P.; Garner, E.L.

    1977-01-01

    The current interest in trace elements in biological materials has created a need for accurate methods of analysis. The source of discrepancies and variations in chromium concentration determinations is often traceable to inadequate methods of sample preparation. Any method of Cr analysis that requires acid digestion of a biological matrix must take into consideration the existence or formation of a volatile Cr component. In addition, because Cr is often present at concentrations less than 1 μg/g, the analytical blank becomes a potential source of error. Chemical procedures have been developed for the digestion of the biological matrix and the separation of Cr without either large analytical blanks or significant losses by volatilization. These procedures have been used for the analysis of NBS Standard Reference Material (SRM) 1569 Brewers Yeast; SRM 1577 Bovine Liver; SRM 1570 Spinach and other biological materials including human hair and nails. At this time, samples containing 1 μg of Cr can be determined with an estimated accuracy of 2 percent

  12. HO2 measurements at atmospheric concentrations using a chemical ionization mass spectrometry

    Science.gov (United States)

    Albrecht, S.; Novelli, A.; Hofzumahaus, A.; Kang, S.; Baker, Y.; Mentel, T. F.; Fuchs, H.

    2017-12-01

    Correct and precise measurements of atmospheric radical species are necessary for a better understanding of the oxidative capacity of the atmosphere. Due to the reactivity of radicals, and their consequent low concentrations, direct measurements of these species are particularly challenging and have been proven in the past to be affected by interfering species. Here we present a chemical ionization source coupled to an APi-HR-TOF-MS (Aerodyne Research Inc.), which has a limit of detection for HO2 radicals well below its atmospheric concentrations ( 1 x 108 molecules cm-3). The instrument was calibrated with a well-established and characterized HO2 calibration source in use for the laser induced fluorescence instrument in the Forschungszentrum Jülich. Within the source, a well characterized amount of HO2 radicals is produced after photolysis of water by a mercury lamp. In addition, several experiments were performed in the atmosphere simulation chamber SAPHIR at the Forschungszentrum Jülich to test for potential interferences. Measurements of HO2 radicals were concurrently detected by a laser induced fluorescence instrument allowing for the comparison of measurements within the two different and independent techniques for various atmospheric conditions regarding concentrations of O3, NOx and VOCs. Results from the intercomparison together with the calibration procedure of the instrument and laboratory characterization will be presented.

  13. Analysis of chemical warfare agents in organic liquid samples with magnetic dispersive solid phase extraction and gas chromatography mass spectrometry for verification of the chemical weapons convention.

    Science.gov (United States)

    Singh, Varoon; Purohit, Ajay Kumar; Chinthakindi, Sridhar; Goud, Raghavender D; Tak, Vijay; Pardasani, Deepak; Shrivastava, Anchal Roy; Dubey, Devendra Kumar

    2016-05-27

    A simple, sensitive and low temperature sample preparation method is developed for detection and identification of Chemical Warfare Agents (CWAs) and scheduled esters in organic liquid using magnetic dispersive solid phase extraction (MDSPE) followed by gas chromatography-mass spectrometry analysis. The method utilizes Iron oxide@Poly(methacrylic acid-co-ethylene glycol dimethacrylate) resin (Fe2O3@Poly(MAA-co-EGDMA)) as sorbent. Variants of these sorbents were prepared by precipitation polymerization of methacrylic acid-co-ethylene glycol dimethacrylate (MAA-co-EGDMA) onto Fe2O3 nanoparticles. Fe2O3@poly(MAA-co-EGDMA) with 20% MAA showed highest recovery of analytes. Extractions were performed with magnetic microspheres by MDSPE. Parameters affecting the extraction efficiency were studied and optimized. Under the optimized conditions, method showed linearity in the range of 0.1-3.0μgmL(-1) (r(2)=0.9966-0.9987). The repeatability and reproducibility (relative standard deviations (RSDs) %) were in the range of 4.5-7.6% and 3.4-6.2% respectively for organophosphorous esters in dodecane. Limits of detection (S/N=3/1) and limit of quantification (S/N=10/1) were found to be in the range of 0.05-0.1μgmL(-1) and 0.1-0.12μgmL(-1) respectively in SIM mode for selected analytes. The method was successfully validated and applied to the extraction and identification of targeted analytes from three different organic liquids i.e. n-hexane, dodecane and silicon oil. Recoveries ranged from 58.7 to 97.3% and 53.8 to 95.5% at 3μgmL(-1) and 1μgmL(-1) spiking concentrations. Detection of diethyl methylphosphonate (DEMP) and O-Ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX) in samples provided by the Organization for Prohibition of Chemical Weapons Proficiency Test (OPCW-PT) proved the utility of the developed method for the off-site analysis of CWC relevant chemicals. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Electron spectroscopy of He and NO using electron impact and multiphoton ionisation

    International Nuclear Information System (INIS)

    Kimman, J.T.N.

    1984-01-01

    This thesis describes two experimental studies which are intended to contribute to our knowledge of the structure of molecules and the decay dynamics of excited molecular states. The two studies have in common that they are both concerned with ionisation processes, in which an accurately known amount of energy is transferred to the target, and energy analysis of the ejected electrons is made. Ionisation is caused either by scattering electrons off the molecules (chapter 2: electron impact ionisation) or by a simultaneous absorption of several photons (chapter 3: multiphoton ionisation). In chapter 2 an electron impact ionisation experiment on Helium is described in which the kinematics of both the scattered and the ejected electrons is fully determined ((e,2e) experiment). (Auth.)

  15. The use of detectors based on ionisation recombination in radiation protection

    International Nuclear Information System (INIS)

    Sullivan, A.H.

    1984-01-01

    Intitial recombination of ionisation in a gas depends on the ionisation density and hence on the linear energy transfer along the tracks of charged particles. This effect can be used as a basis for instruments that respond to different types of ionising radiation approximately in the way required by the quality factor-linear energy transfer relation recommended by the ICRP for use in radiation protection. Empirical instruments based on ionisation recombination that have been used for radiation protection measurements are reviewed, and relations are derived from recombination theory that show that the response of such detectors can be readily predicted. The usefulness of recombination instruments in radiation protection is discussed and their advantages and limitations assessed. It is shown that their main application will be as reference instruments against which other detectors can be calibrated. As an extension to using recombination detectors as reference instruments, the feasibility of specifying radiation quality in terms of ionisation recombination is investigated. (author)

  16. Glacier mass balance reconstruction by sublimation induced enrichment of chemical species on Cerro Tapado (Chilean Andes

    Directory of Open Access Journals (Sweden)

    P. Ginot

    2006-01-01

    Full Text Available A 36 m long ice core down to bedrock from the Cerro Tapado glacier (5536 m a.s.l, 30°08' S, 69°55' W was analyzed to reconstruct past climatic conditions for Northern Chile. Because of the marked seasonality in the precipitation (short wet winter and extended dry summer periods in this region, major snow ablation and related post-depositional processes occur on the glacier surface during summer periods. They include predominantly sublimation and dry deposition. Assuming that, like measured during the field campaign, the enrichment of chloride was always related to sublimation, the chemical record along the ice core may be applied to reconstruct the history of such secondary processes linked to the past climatic conditions over northern Chile. For the time period 1962–1999, a mean annual net accumulation of 316 mm water equivalent (weq and 327 mm weq loss by sublimation was deduced by this method. This corresponds to an initial total annual accumulation of 539 mm weq. The annual variability of the accumulation and sublimation is related with the Southern Oscillation Index (SOI: higher net-accumulation during El-Niño years and more sublimation during La Niña years. The deepest part of the ice record shows a time discontinuity; with an ice body deposited under different climatic conditions: 290 mm higher precipitation but with reduced seasonal distribution (+470 mm in winter and –180 mm in summer and –3°C lower mean annual temperature. Unfortunately, its age is unknown. The comparison with regional proxy data however let us conclude that the glacier buildup did most likely occur after the dry mid-Holocene.

  17. Paper spray mass spectrometry applied in the monitoring of a chemical system in dynamic chemical equilibrium: the redox process of methylene blue.

    Science.gov (United States)

    de Paula, Camila Cristina Almeida; Valadares, Alberto; Jurisch, Marina; Piccin, Evandro; Augusti, Rodinei

    2016-05-15

    The monitoring of chemical systems in dynamic equilibrium is not an easy task. This is due to the high rate at which the system returns to equilibrium after being perturbed, which hampers the possibility of following the aftereffects of the disturbance. In this context, it is necessary to use a fast analytical technique that requires no (or minimal) sample preparation, and which is capable of monitoring the species constituting the system in equilibrium. Paper spray ionization mass spectrometry (PS-MS), a recently introduced ambient ionization technique, has such characteristics and hence was chosen for monitoring a model system: the redox process of methylene blue. The model system evaluated herein was composed of three cationic species of methylene blue (MB), which coexist in a dynamic redox system: (1) [MB](+) of m/z 284 (cationic MB); (2) [MB + H + e](+•) of m/z 285 (the protonated form of a transient species resulting from the reduction of [MB](+) ); (3) [MB + 2H + 2e](+) or [leuco-MB + H](+) of m/z 286 (the protonated leuco form of MB). Aliquots of a MB solution were collected before and after the addition of a reducing agent (metallic zinc) and directly analyzed by PS-MS for identification of the predominant cationic species at different conditions. The mass spectra revealed that before the addition of the reducing agent the ion of m/z 284 (cationic MB) is the unique species. Upon the addition of the reducing agent and acid, however, the solution continuously undergo discoloration while reduced species derived directly from cationic MB (m/z 285 and 286) are detected in the mass spectra with increasing intensities. Fragmentation patterns obtained for each ionic species, i.e. [MB](+) , [MB + H + e](+•) and [leuco-MB + H](+) , shown to be consistent with the proposed structures. The PS-MS technique proved to be suitable for an in situ and 'near' real-time analysis of the dynamic equilibrium involving the redox of MB in aqueous medium. The data clearly

  18. Building biomarker libraries with novel chemical sensors: correlating differential mobility spectrometer signal outputs with mass spectrometry data

    International Nuclear Information System (INIS)

    Schivo, Michael; Kenyon, Nicholas J; Aksenov, Alexander A; Bardaweel, Hamzeh; Zhao Weixiang; Davis, Cristina E

    2011-01-01

    Gas chromatography/mass spectrometry (GC/MS) is a widely used analytic tool for qualitative and quantitative analysis of volatile and semi-volatile compounds. However, GC/MS use is limited by its large size, lack of portability, high cost and inherent complexity. Smaller instruments capable of high-throughput analysis of volatile compounds have the potential of combining MS-like sensitivity with portability. The micromachined differential mobility spectrometer (DMS) is a miniature sensor capable of registering volatile compounds in sub-parts-per-million (ppm) concentrations. It is small, portable, and can be coupled with multiple other compound separation methods. Here we describe paired volatile sample analyses using both GC/MS and GC/DMS which show that the DMS is capable of registering known compounds as verified by MS. Furthermore, we show that MS can be used to help build a library for our unique DMS sensor outputs and detect compounds in chemically complex backgrounds.

  19. Effects of magnetic, radiation and chemical reaction on unsteady heat and mass transfer flow of an oscillating cylinder

    Science.gov (United States)

    Ahmed, Rubel; Rana, B. M. Jewel; Ahmmed, S. F.

    2017-06-01

    The effects of magnetic, radiation and chemical reaction parameters on the unsteady heat and mass transfer boundary layer flow past an oscillating cylinder is considered. The dimensionless momentum, energy and concentration equations are solved numerically by using explicit finite difference method with the help of a computer programming language Compaq visual FORTRAN 6.6a. The obtained results of this study have been discussed for different values of well-known parameters with different time steps. The effect of these parameters on the velocity field, temperature field and concentration field, skin-friction, Nusselt number, streamlines and isotherms has been studied and results are presented by graphically represented by the tabular form quantitatively. The stability and convergence analysis of the solution parameters that have been used in the mathematical model have been tested.

  20. Final report of the Buffer Mass Test - Volume 3: Chemical and physical stability of the buffer materials

    International Nuclear Information System (INIS)

    Pusch, R.

    1985-11-01

    The Buffer Mass Test offered a possibility to investigate whether chemical changes took place in the smectite component at heating to 125 degrees C for about one year. The alterations that could possibly take place were a slight charge change in the crystal lattice with an associated precipitation of silica compounds, and a tendency of illite formation. The analysis showed that there were indications of both but to such a slight extent that the processes could not have affected the physical properties, which was also demonstrated by determining the swelling pressure and the hydraulic conductivity. The BMT also showed that the erodibility of bentonite-based buffer materials is less than or about equal to what can be expected on theoretical grounds. (author)