WorldWideScience

Sample records for check valve performance

  1. NRC valve performance test program - check valve testing

    International Nuclear Information System (INIS)

    Jeanmougin, N.M.

    1987-01-01

    The Valve Performance Test Program addresses the current requirements for testing of pressure isolation valves (PIVs) in light water reactors. Leak rate monitoring is the current method used by operating commercial power plants to survey the condition of their PIVs. ETEC testing of three check valves (4-inch, 6-inch, and 12-inch nominal diameters) indicates that leak rate testing is not a reliable method for detecting impending valve failure. Acoustic emission monitoring of check valves shows promise as a method of detecting loosened internals damage. Future efforts will focus on evaluation of acoustic emission monitoring as a technique for determining check valve condition. Three gate valves also will be tested to evaluate whether the check valve results are applicable to gate type PIVs

  2. The use of check valve performance data to support new concepts (probabilistic risk assessment, condition monitoring) for check valve program

    Energy Technology Data Exchange (ETDEWEB)

    Hart, K.A.; Gower, D.

    1996-12-01

    The concept of developing an integrated check valve database based on the Nuclear Power Reliability Data System (NPRDS) data was presented at the last Symposium. The Nuclear Industry Check Valve Group (NIC), working in cooperation with the Oak Ridge National Laboratory (ORNL), has completed an operational database of check valve performance from 1984 to the present. NIC has committed to the nuclear industry to periodically update the data and maintain this information accessible. As the new concepts of probabilistic risk analysis and condition monitoring are integrated into the American Society of Mechanical Engineers (ASME) Code, a critical element will be performance data. From check valve performance data, feasible failure modes and rates can be established. When a failure rate or frequency of failures can be established based on a significant enough population (sampling), a more solid foundation for focusing resources and determining appropriate frequencies and testing can be determined. The presentation will give the updated status of the NIC Check Valve Performance Database covering (1) methodology used to combine the original ORNL data; (2) process/controls established for continuing update and refinement of the data; (3) discussion of how this data is being utilized by (a) OM-22 for condition monitoring, and (b) risk-based inservice testing work of Westinghouse Owners` Group; and (4) results/trends of data evaluations. At the 1994 Symposium, ORNL provided an update as of 1991 to their original work of 1984 -1990 which they had performed to characterize check valve degradations and failures in the nuclear industry. These characterizations will be updated to 1995 and additional reviews provided to give insight into the current condition and trends of check valve performance.

  3. The use of check valve performance data to support new concepts (probabilistic risk assessment, condition monitoring) for check valve program

    International Nuclear Information System (INIS)

    Hart, K.A.; Gower, D.

    1996-01-01

    The concept of developing an integrated check valve database based on the Nuclear Power Reliability Data System (NPRDS) data was presented at the last Symposium. The Nuclear Industry Check Valve Group (NIC), working in cooperation with the Oak Ridge National Laboratory (ORNL), has completed an operational database of check valve performance from 1984 to the present. NIC has committed to the nuclear industry to periodically update the data and maintain this information accessible. As the new concepts of probabilistic risk analysis and condition monitoring are integrated into the American Society of Mechanical Engineers (ASME) Code, a critical element will be performance data. From check valve performance data, feasible failure modes and rates can be established. When a failure rate or frequency of failures can be established based on a significant enough population (sampling), a more solid foundation for focusing resources and determining appropriate frequencies and testing can be determined. The presentation will give the updated status of the NIC Check Valve Performance Database covering (1) methodology used to combine the original ORNL data; (2) process/controls established for continuing update and refinement of the data; (3) discussion of how this data is being utilized by (a) OM-22 for condition monitoring, and (b) risk-based inservice testing work of Westinghouse Owners' Group; and (4) results/trends of data evaluations. At the 1994 Symposium, ORNL provided an update as of 1991 to their original work of 1984 -1990 which they had performed to characterize check valve degradations and failures in the nuclear industry. These characterizations will be updated to 1995 and additional reviews provided to give insight into the current condition and trends of check valve performance

  4. Check valve

    Science.gov (United States)

    Upton, H.A.; Garcia, P.

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs.

  5. Check valve

    International Nuclear Information System (INIS)

    Upton, H.A.; Garcia, P.

    1999-01-01

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs

  6. Non intrusive check valve diagnostics at Bruce A

    International Nuclear Information System (INIS)

    Marsch, S.P.

    1997-01-01

    Bruce A purchased non intrusive check valve diagnostic equipment in 1995 to ensure operability and availability of critical check valves in the Station. Diagnostics can be used to locate and monitor check valve degradation modes. Bruce A initiated a pilot program targeting check valves with flow through them and ones that completed open or close cycles. Approaches to determine how to confirm operability of passive check valves using non intrusive techniques were explored. A sample population of seventy-three check valves was selected to run the pilot program on prior to complete implementation. The pilot program produced some significant results and some inconclusive results. The program revealed a major finding that check valve performance modeling is required to ensure continuous operability of check valves. (author)

  7. Non intrusive check valve diagnostics at Bruce A

    Energy Technology Data Exchange (ETDEWEB)

    Marsch, S.P. [Ontario Hydro, Bruce Nuclear Generating Station A, Tiverton, ON (Canada)

    1997-07-01

    Bruce A purchased non intrusive check valve diagnostic equipment in 1995 to ensure operability and availability of critical check valves in the Station. Diagnostics can be used to locate and monitor check valve degradation modes. Bruce A initiated a pilot program targeting check valves with flow through them and ones that completed open or close cycles. Approaches to determine how to confirm operability of passive check valves using non intrusive techniques were explored. A sample population of seventy-three check valves was selected to run the pilot program on prior to complete implementation. The pilot program produced some significant results and some inconclusive results. The program revealed a major finding that check valve performance modeling is required to ensure continuous operability of check valves. (author)

  8. Next-generation nozzle check valve significantly reduces operating costs

    Energy Technology Data Exchange (ETDEWEB)

    Roorda, O. [SMX International, Toronto, ON (Canada)

    2009-01-15

    Check valves perform an important function in preventing reverse flow and protecting plant and mechanical equipment. However, the variety of different types of valves and extreme differences in performance even within one type can change maintenance requirements and life cycle costs, amounting to millions of dollars over the typical 15-year design life of piping components. A next-generation non-slam nozzle check valve which prevents return flow has greatly reduced operating costs by protecting the mechanical equipment in a piping system. This article described the check valve varieties such as the swing check valve, a dual-plate check valve, and nozzle check valves. Advancements in optimized design of a non-slam nozzle check valve were also discussed, with particular reference to computer flow modelling such as computational fluid dynamics; computer stress modelling such as finite element analysis; and flow testing (using rapid prototype development and flow loop testing), both to improve dynamic performance and reduce hydraulic losses. The benefits of maximized dynamic performance and minimized pressure loss from the new designed valve were also outlined. It was concluded that this latest non-slam nozzle check valve design has potential applications in natural gas, liquefied natural gas, and oil pipelines, including subsea applications, as well as refineries, and petrochemical plants among others, and is suitable for horizontal and vertical installation. The result of this next-generation nozzle check valve design is not only superior performance, and effective protection of mechanical equipment but also minimized life cycle costs. 1 fig.

  9. Swing check valve

    International Nuclear Information System (INIS)

    Eminger, H.E.

    1977-01-01

    A swing check valve which includes a valve body having an inlet and outlet is described. A recess in the valve body designed to hold a seal ring and a check valve disc swingable between open and closed positions. The disc is supported by a high strength wire secured at one end in a support spacer pinned through bearing blocks fixed to the valve body and at its other end in a groove formed on the outer peripheral surface of the disc. The parts are designed and chosen such to provide a lightweight valve disc which is held open by minimum velocity of fluid flowing through the valve which thus reduces oscillations and accompanying wear of bearings supporting the valve operating parts. (Auth.)

  10. Thermal performance of horizontal closed-loop oscillating heat-pipe with check valves

    International Nuclear Information System (INIS)

    Rittidech, S.; Pipatpaiboon, N.; Thongdaeng, S.

    2010-01-01

    This research investigated the thermal performance of various horizontal closed-loop oscillating heat-pipe systems with check valves (HCLOHPs/CVs). Numerous test systems were constructed using copper capillary tubes with assorted inner diameters, evaporator lengths, and check valves. The test systems were evaluated under normal operating conditions using ethanol, R123, and distilled water as working fluids. The system's evaporator sections were heated by hot water from a hot bath, and the heat was removed from the condenser sections by cold water from a cool bath. The adiabatic sections were well insulated with foam insulators. The heat-transfer performance of the various systems was evaluated in terms of the rate of heat transferred to the cold water at the condenser. The results showed that the heat-transfer performance of an HCLOHP/CV system could be improved by decreasing the evaporator length. The highest performance of all tested systems was obtained when the maximum number of system check valves was 2. The maximum heat flux occurred with a 2 mm inner diameter tube, and R123 was determined to be the most suitable working fluid

  11. Check valves aging assessment

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1991-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, the Oak Ridge National Laboratory (ORNL) has carried out an assessment of several check value diagnostic monitoring methods, in particular, those based on measurements of acoustic emission, ultrasonics, and magnetic flux. The evaluations have focussed on the capabilities of each method to provide information useful in determining check valve aging and service wear effects, check valve failures, and undesirable operating modes. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data, including data obtained from the vendors who recently participated in a comprehensive series of tests directed by a nuclear industry users group. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two novel nonintrusive monitoring methods were developed that provide several unique capabilities. These methods, based on external ac- an dc-magnetic monitoring are also described. None of the examined methods could, by themselves, monitor both the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information

  12. Plant experience with check valves in passive systems

    Energy Technology Data Exchange (ETDEWEB)

    Pahladsingh, R R [GKN Joint Nuclear Power Plant, Dodewaard (Netherlands)

    1996-12-01

    In the design of the advanced nuclear reactors there is a tendency to introduce more passive safety systems. The 25 year old design of the GKN nuclear reactor is different from the present BWR reactors because of some special features, such as the Natural Circulation - and the Passive Isolation Condenser system. When reviewing the design, one can conclude that the plant has 25 years of experience with check valves in passive systems and as passive components in systems. The result of this experience has been modeled in a plant-specific ``living PSA`` for the plant. A data-analysis has been performed on components which are related to the safety systems in the plant. As part of this study also the check valves have been taken in consideration. At GKN, the check valves have shown to be reliable components in the systems and no catastrophic failures have been experienced during the 25 years of operation. Especially the Isolation Condenser with its operation experience can contribute substantially to the insight of check valves in stand-by position at reactor pressure and operating by gravity under different pressure conditions. With the introduction of several passive systems in the SBWR-600 design, such as the Isolation Condensers, Gravity Driven Cooling, and Suppression Pool Cooling System, the issue of reliability of check valves in these systems is actual. Some critical aspects for study in connection with check valves are: What is the reliability of a check valve in a system at reactor pressure, to open on demand; what is the reliability of a check valve in a system at low pressure (gravity), to open on demand; what is the reliability of a check valve to open/close when the stand-by check wave is at zero differential pressure. The plant experience with check valves in a few essential safety systems is described and a brief introduction will be made about the application of check valves in the design of the new generation reactors is given. (author). 6 figs, 1 tab.

  13. Simple Check Valves for Microfluidic Devices

    Science.gov (United States)

    Willis, Peter A.; Greer, Harold F.; Smith, J. Anthony

    2010-01-01

    A simple design concept for check valves has been adopted for microfluidic devices that consist mostly of (1) deformable fluorocarbon polymer membranes sandwiched between (2) borosilicate float glass wafers into which channels, valve seats, and holes have been etched. The first microfluidic devices in which these check valves are intended to be used are micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. In this application, it will be necessary to store some liquid samples in reservoirs in the devices for subsequent laboratory analysis, and check valves are needed to prevent cross-contamination of the samples. The simple check-valve design concept is also applicable to other microfluidic devices and to fluidic devices in general. These check valves are simplified microscopic versions of conventional rubber- flap check valves that are parts of numerous industrial and consumer products. These check valves are fabricated, not as separate components, but as integral parts of microfluidic devices. A check valve according to this concept consists of suitably shaped portions of a deformable membrane and the two glass wafers between which the membrane is sandwiched (see figure). The valve flap is formed by making an approximately semicircular cut in the membrane. The flap is centered over a hole in the lower glass wafer, through which hole the liquid in question is intended to flow upward into a wider hole, channel, or reservoir in the upper glass wafer. The radius of the cut exceeds the radius of the hole by an amount large enough to prevent settling of the flap into the hole. As in a conventional rubber-flap check valve, back pressure in the liquid pushes the flap against the valve seat (in this case, the valve seat is the adjacent surface of the lower glass wafer), thereby forming a seal that prevents backflow.

  14. The online sealing performance test of the primary circuit pressure boundary check valve in nuclear power plants

    International Nuclear Information System (INIS)

    Yang Yunfei; Huang Huimin

    2013-01-01

    The primary circuit pressure boundary check valves of 320 MW pressurized water reactor is a nuclear grade I key equipment. The sealing demand is very high, which is directly related to the internal leakage rate of the primary circuit system. After the welding check valve is repaired, the sealing performance is judged by color printing checks. If there is water or humid vapor in the pipe, it will affect the accuracy of the color printing checks. For the particularity of the online check valve tightness test, online detecting device is designed by the hydraulic pressure drop method in other nuclear power plants, but the method has some shortcomings and restrictions. In this paper, we design a reliable and portable test equipment by the low-pressure gas seal test flow measurement, which make accurate and quantitative judgment of sealing property after the pressure boundary check valves are repaired. (authors)

  15. Magnetically operated check valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-06-01

    A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  16. Magnetic Check Valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-01-01

    Poppet in proposed check valve restored to closed condition by magnetic attraction instead of spring force. Oscillations suppressed, with consequent reduction of wear. Stationary magnetic disk mounted just upstream of poppet, also containing magnet. Valve body nonmagnetic. Forward pressure or flow would push poppet away from stationary magnetic disk so fluid flows easily around poppet. Stop in valve body prevents poppet from being swept away. When flow stopped or started to reverse, magnetic attraction draws poppet back to disk. Poppet then engages floating O-ring, thereby closing valve and preventing reverse flow. Floating O-ring facilitates sealing at low loads.

  17. Role of recent research in improving check valve reliability at nuclear power plants

    International Nuclear Information System (INIS)

    Kalsi, M.S.; Horst, C.L.; Wang, J.K.; Sharma, V.

    1990-01-01

    Check valve failures at nuclear power plants in recent years have led to serious safety concerns, and caused extensive damage to other plant components which had a significant impact on plant availability. In order to understand the failure mechanism and improve the reliability of check valves, a systematic research effort was proposed by Kalsi Engineering, Inc. to U.S. Nuclear Regulatory Commission (NRC). The overall goal of the research was to develop models for predicting the performance and degradation of swing check valves in nuclear power plant systems so that appropriate preventive maintenance or design modifications can be performed to improve the reliability of check valves. Under Phase I of this research, a large matrix of tests was run with instrumented swing check valves to determine the stability of the disc under a variety of upstream flow disturbances, covering a wide range of disc stop positions and flow velocities in two different valve sizes. The goals of Phase II research were to develop predictive models which quantify the anticipated degradation of swing check valves that have flow disturbances closely upstream of the valve and are operating under flow velocities that do not result in full disc opening. This research allows the inspection/maintenance activities to be focussed on those check valves that are more likely to suffer premature degradation. The quantitative wear and fatigue prediction methodology can be used to develop a sound preventive maintenance program. The results of the research also show the improvements in check valve performance/reliability that can be achieved by certain modifications in the valve design

  18. Methodology for Check Valve Selection to Maintain the Integrity of Pipeline against the Check Valve Slam for the KIJANG Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dayong; Yoon, Hyungi; Seo, Kyoungwoo; Kim, Seonhoon [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The check valve slam results in a water hammer and unexpected system pressure rise in the pipeline. Sometimes, the pressure rise by check valve slam in the pipeline exceeds the design pressure and then it causes the rupture of pipeline. Therefore, check valve slam significantly influences on the integrity of pipe. Especially, this it is most likely to occur by check valve installed in the discharge of pump when one pump trips among the two or more running in parallel pump system. This study focuses on the check valve selection to maintain the integrity of PCS pipeline against the check valve slam. If design head for KJRR PCS pipeline is higher than the sum of static head and 11 m, any type check valves can be installed at the discharge of pump. However, if design head for KJRR PCS pipeline is lower than the sum of static head and 11 m, installation of swing and ball check on the discharge of pump must be avoid to prevent the rupture of PCS pipeline.

  19. Methodology for Check Valve Selection to Maintain the Integrity of Pipeline against the Check Valve Slam for the KIJANG Research Reactor

    International Nuclear Information System (INIS)

    Kim, Dayong; Yoon, Hyungi; Seo, Kyoungwoo; Kim, Seonhoon

    2016-01-01

    The check valve slam results in a water hammer and unexpected system pressure rise in the pipeline. Sometimes, the pressure rise by check valve slam in the pipeline exceeds the design pressure and then it causes the rupture of pipeline. Therefore, check valve slam significantly influences on the integrity of pipe. Especially, this it is most likely to occur by check valve installed in the discharge of pump when one pump trips among the two or more running in parallel pump system. This study focuses on the check valve selection to maintain the integrity of PCS pipeline against the check valve slam. If design head for KJRR PCS pipeline is higher than the sum of static head and 11 m, any type check valves can be installed at the discharge of pump. However, if design head for KJRR PCS pipeline is lower than the sum of static head and 11 m, installation of swing and ball check on the discharge of pump must be avoid to prevent the rupture of PCS pipeline

  20. Improvement of seawater booster pump outlet check valve

    International Nuclear Information System (INIS)

    Li Xuning; Du Yansong; Huang Huimin

    2010-01-01

    Conventional island seawater booster pump set of QNPC 310 MWe unit are very important in the whole circulating cooling system, and the integrate function of seawater booster pump outlet check valve is the foundation of steady operation of the seawater booster pump set. The article mainly introduce that through the analyses to the reason to the problem that the seawater booster pump outlet check valve of QNPC 310 MWe unit appeared in past years by our team, and considering the influence of operation condition and circumstance, the team improve the seawater booster pump outlet check valve from swing check valve to shuttle check valve which operate more appropriately in the system. By the test of continuous practice, we make further modification to the inner structure of shuttle check valve contrapuntally, and therefore we solve the problem in seawater booster pump outlet check valve fundamentally which has troubled the security of system operation in past years, so we realize the aim of technical improvement and ensure that the system operate in safety and stability. (authors)

  1. Mitigating check valve slamming and subsequentwater hammer events for PPFS using MOC

    International Nuclear Information System (INIS)

    Tian Wenxi; Su Guanghui; Wang Gaopeng; Qiu Suizheng; Xiao Zejun

    2009-01-01

    The method of characteristic (MOC) was adopted to analyze the check valve-induced water hammer behaviors for a Parallel Pumps Feedwater System (PPFS) during the alternate startup process. The motion of check valve disc was simulated using inertial valve model. Transient parameters including the pressure oscillation, local flow velocity and slamming of the check valve disc etc. have been obtained. The results showed that severe slamming between the valve disc and valve seat occurred during the alternate startup of parallel pumps. The induced maximum pressure vibration amplitude is up to 5.0 MPa. The scheme of appending a damping torque to slow down the check valve closing speed was also performed to mitigate of water hammer. It has been numerically approved to be an effective approach. (authors)

  2. Mitigating check valve slamming and subsequentwater hammer events for PPFS using MOC

    Institute of Scientific and Technical Information of China (English)

    TIAN Wenxi; SU Guanghui; WANG Gaopeng; QIU Suizheng; XIAO Zejun

    2009-01-01

    The method of characteristic (MOC) was adopted to analyze the check valve-induced water hammer behaviors for a Parallel Pumps Feedwater System (PPFS) during the alternate startup process. The motion of check valve disc was simulated using inertial valve model. Transient parameters including the pressure oscillation, local flow velocity and slamming of the check valve disc etc. have been obtained. The results showed that severe slamming between the valve disc and valve seat occurred during the alternate startup of parallel pumps. The induced maximum pressure vibration amplitude is up to 5.0 MPa. The scheme of appending a damping torque to slow down the check valve closing speed was also performed to mitigate of water hammer. It has been numerically approved to be an effective approach.

  3. Application of risk-based methods to inservice testing of check valves

    Energy Technology Data Exchange (ETDEWEB)

    Closky, N.B.; Balkey, K.R.; McAllister, W.J. [and others

    1996-12-01

    Research efforts have been underway in the American Society of Mechanical Engineers (ASME) and industry to define appropriate methods for the application of risk-based technology in the development of inservice testing (IST) programs for pumps and valves in nuclear steam supply systems. This paper discusses a pilot application of these methods to the inservice testing of check valves in the emergency core cooling system of Georgia Power`s Vogtle nuclear power station. The results of the probabilistic safety assessment (PSA) are used to divide the check valves into risk-significant and less-risk-significant groups. This information is reviewed by a plant expert panel along with the consideration of appropriate deterministic insights to finally categorize the check valves into more safety-significant and less safety-significant component groups. All of the more safety-significant check valves are further evaluated in detail using a failure modes and causes analysis (FMCA) to assist in defining effective IST strategies. A template has been designed to evaluate how effective current and emerging tests for check valves are in detecting failures or in finding significant conditions that are precursors to failure for the likely failure causes. This information is then used to design and evaluate appropriate IST strategies that consider both the test method and frequency. A few of the less safety-significant check valves are also evaluated using this process since differences exist in check valve design, function, and operating conditions. Appropriate test strategies are selected for each check valve that has been evaluated based on safety and cost considerations. Test strategies are inferred from this information for the other check valves based on similar check valve conditions. Sensitivity studies are performed using the PSA model to arrive at an overall IST program that maintains or enhances safety at the lowest achievable cost.

  4. Recent improvements in check valve monitoring methods

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1991-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, ORNL has carried out an evaluation of three check valve monitoring methods: acoustic emission, ultrasonic inspection, and magnetic flux signature analysis (MFSA). This work has focussed on determining the capabilities of each method to provide diagnostic information useful in determining check valve aging and service wear effects (degradation) and undesirable operating modes. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two novel nonintrusive monitoring methods were developed (external ac- and dc-magnetic monitoring) that provide several improvements over the other methods. None of the examined methods could, by themselves, monitor the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data to illustrate the capabilities of these methods to detect simulated check valve degradation. 3 refs., 22 figs., 4 tabs

  5. Recent improvements in check valve monitoring methods

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1990-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, ORNL has carried out an evaluation of three check valve monitoring methods: acoustic emission, ultrasonic inspection, and magnetic flux signature analysis (MFSA). This work has focused on determining the capabilities of each method to provide diagnostic information useful in determining check valve aging and service wear effects (degradation) and undesirable operating modes. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two noval nonintrusive monitoring methods were developed (external ac- and dc-magnetic monitoring) that provide several improvements over the other methods. None of the examined methods could, by themselves, monitor the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data to illustrate the capabilities of these methods to detect simulated check valve degradation. 3 refs., 22 figs., 4 tabs

  6. Check valve diagnostics utilizing acoustic and magnetic technologies

    International Nuclear Information System (INIS)

    Agostinelli, A.

    1991-01-01

    The potential hazards associated with check valve failures make it necessary to detect check valve problems before they cause significant damage. In the nuclear industry, check valve failures are known to have resulted in damaging water hammer conditions, overpressurization of low pressure systems, steam binding of auxiliary feedwater pumps, and other serious component damage in power plant environments. Similar problems exist in fossil power and various process industries, but the resources dedicated to valve maintenance issues are greatly reduced. However, the trend toward plant life extension, predictive maintenance, and maximum operating efficiency will raise the general awareness of check valve maintenance in commercial (non-nuclear) applications. Although this paper includes specific references to the nuclear industry, the check valve problem conditions and diagnostic techniques apply across all power and process plant environments. The ability to accurately diagnose check valve conditions using non-intrusive, predictive maintenance testing methods allows for a more cost-efficient, productive maintenance program. One particular diagnostic system, called Quickcheck trademark, assists utilities in addressing these concerns. This article presents actual field test data and analysis that demonstrate the power of check valve diagnostics. Prior to presenting the field data, a brief overview of the system is overviewed

  7. Glovebox pressure relief and check valve

    Energy Technology Data Exchange (ETDEWEB)

    Blaedel, K.L.

    1986-03-17

    This device is a combined pressure relief valve and check valve providing overpressure protection and preventing back flow into an inert atmosphere enclosure. The pressure relief is embodied by a submerged vent line in a mercury reservior, the releif pressure being a function of the submerged depth. The pressure relief can be vented into an exhaust system and the relieving pressure is only slightly influenced by the varying pressure in the exhaust system. The check valve is embodied by a ball which floats on the mercury column and contacts a seat whenever vacuum exists within the glovebox enclosure. Alternatively, the check valve is embodied by a vertical column of mercury, the maximum back pressure being a function of the height of the column of mercury.

  8. Glovebox pressure relief and check valve

    International Nuclear Information System (INIS)

    Blaedel, K.L.

    1986-01-01

    This device is a combined pressure relief valve and check valve providing overpressure protection and preventing back flow into an inert atmosphere enclosure. The pressure relief is embodied by a submerged vent line in a mercury reservior, the releif pressure being a function of the submerged depth. The pressure relief can be vented into an exhaust system and the relieving pressure is only slightly influenced by the varying pressure in the exhaust system. The check valve is embodied by a ball which floats on the mercury column and contacts a seat whenever vacuum exists within the glovebox enclosure. Alternatively, the check valve is embodied by a vertical column of mercury, the maximum back pressure being a function of the height of the column of mercury

  9. Principle and opening-closing character analysis of DC check valve

    International Nuclear Information System (INIS)

    Han Xu; Zhou Yu

    2006-01-01

    When the behaviour of main pump in PWR power plant change, as a result of arresting fluid countercurrent current by check valve, water hammer phenomena met occur more or less in loop. Serious water hammer not only met brought incident of over pressure, imperil pressure boundary, but also may engender check valve lapse. DC check valve is a kind of new theory check valve, is designed to avoid serious water hammer phenomena at tradition check valve closing, the analyses and experiment indicate that DC check valve can availably solve water hammer problem in the loop, and be able to reliably prevent fluid countercurrent. (authors)

  10. Transient analysis for a system with a tilted disc check valve

    International Nuclear Information System (INIS)

    Jeung, Jaesik; Lee, Kyukwang; Cho, Daegwan

    2014-01-01

    Check valves are used to prevent reverse flow conditions in a variety of systems in nuclear power plants. When a check valve is closed by a reverse flow, the transient load can jeopardize the structural integrity on the piping system and its supports. It may also damage intended function of the in-line components even though the severity of the load differs and depends strongly on types of the check valves. To incorporate the transient load in the piping system, it is very important to properly predict the system response to transients such as a check valve closure accompanied by pump trip and to evaluate the system transient. The one-dimensional transient simulation codes such as the RELAP5/MOD3.3 and TRACE were used. There has not been a single model that integrates the two codes to handle the behavior of a tilted disc check valve, which is designed to mitigate check valve slams by shorting the travel of the disc. In this paper a model is presented to predict the dynamic motion of a tilted disc check valve in the transient simulation using the RELAP5/MOD3.3 code and the model is incorporated in a system transient analysis using control variables of the code. In addition, transient analysis for Essential Service Water (ESW) system is performed using the proposed model and the associated load is evaluated for the system. (author)

  11. Review and analysis of check valve failure data

    International Nuclear Information System (INIS)

    Todd, M.D.; Casada, D.A.

    1992-01-01

    Check valve operating problems in recent years have resulted in significant operating transients, increased cost and decreased system availability. There has been, in response, additional attention given to check valves by utilities, as well as the US Nuclear Regulatory Commission and the American Society of Mechanical Engineers Operation and Maintenance Committee. All these organizations have the fundamental goal of ensuring reliable operation of check valves. A key ingredient to an engineering-oriented reliability improvement effort is a thorough understanding of relevant historical experience. Oak Ridge National Laboratory is currently conducting a detailed review of historical failure data available through the Institute of Nuclear Power Operation's Nuclear Plant Reliability Data System. The focus of the review is on check valve failures that have involved significant degradation of the valve internal parts. A variety of parameters are being considered during the review, including size, age, system of service, method of failure discovery, the affected valve parts, attributed causes, and corrective actions

  12. Ball check valve

    International Nuclear Information System (INIS)

    Bevilacqua, F.

    1978-01-01

    A pressurized nuclear reactor having an instrument assembly sheathed in a metallic tube which is extended vertically upward into the reactor core by traversing a metallic guide tube which is welded to the wall of the vessel is described. Sensors in each instrument assembly are connected to instruments outside the vessel to manifest the conditions within the core. Each instrument assembly probe is moved into position within a metallic guide channel. The guide channel penetrates the wall of the vessel and forms part of the barrier to the environment within the pressure vessel. Each channel includes a ball check valve which is opened by the instrument assembly probe when the probe passes through the valve. A ball valve element is moved from its seat by the probe to a position lateral of the bore of the channel and is guided to its seat along a sloped path within the valve body when the probe is removed. 5 claims, 3 figures

  13. Vertical pump with free floating check valve

    International Nuclear Information System (INIS)

    Lindsay, M.

    1980-01-01

    A vertical pump is described which has a bottom discharge with a free floating check valve disposed in the outlet plenum thereof. The free floating check valve comprises a spherical member with a hemispherical cage-like member attached thereto which is capable of allowing forward or reverse flow under appropriate conditions while preventing reverse flow under inappropriate conditions

  14. Acoustic emission testing of piston check valves

    International Nuclear Information System (INIS)

    Stewart, D.L.

    1994-01-01

    Based on test experience at Comanche Peak Unit 1, an acoustic emission data evaluation matrix for piston check valves has been developed. The degradations represented in this matrix were selected based on Edwards piston check valve failure data reported in the Nuclear Plant Reliability Data System. Evidence to support this matrix was collected from site test data on a variety of valve types. Although still under refinement, the matrix provides three major attributes for closure verification, which have proven useful in developing test procedures for inservice testing and preventing unnecessary disassembly

  15. Assessment of diagnostic methods for determining degradation of check valves

    International Nuclear Information System (INIS)

    Haynes, H.D.; Farmer, W.S.

    1992-01-01

    The Oak Ridge National Laboratory (ORNL) has carried out a comprehensive aging assessment of check valves in support of the Nuclear Plant Aging Research (NPAR) program. This paper provides a summary of the ORNL check valve aging assessment with emphasis on the identification, evaluation, and application of check valve monitoring methods and techniques. Several check valve monitoring methods are described and compared. These methods include: acoustic emission monitoring, ultrasonic inspection, magnetic flux signature analysis (MFSA), external magnetics. These diagnostic technologies were shown to be useful in determining check valve condition (e.g., disc position, disc motion, and seat leakage), although none of the methods was by itself, successful in monitoring all three condition indicators. The combination of acoustic emission with either ultrasonics or one of the magnetic technologies, however, yields a monitoring system that succeeds in providing the sensitivity to detect all major check valve operating conditions. Other areas covered in the paper include descriptions of relevant regulatory issues, utility group activities, and interactions ORNL has had with outside organizations for the purpose of disseminating research results

  16. Development of a butterfly check valve model under natural circulation conditions

    International Nuclear Information System (INIS)

    Rao, Yuxian; Yu, Lei; Fu, Shengwei; Zhang, Fan

    2015-01-01

    Highlights: • Bases on Lim’s swing check valve model, a butterfly check valve model was developed. • The method to quantify the friction torque T F in Li’s model was corrected. • The developed model was implemented into the RELAP5 code and verified. - Abstract: A butterfly check valve is widely used to prevent a reverse flow in the pipe lines of a marine nuclear power plant. Under some conditions, the natural circulation conditions in particular, the fluid velocity through the butterfly check valve might become too low to hold the valve disk fully open, thereby the flow resistance of the butterfly check valve varies with the location of the valve disk and as a result the fluid flow is significantly affected by the dynamic motion of the valve disk. Simulation of a pipe line that includes some butterfly check valves, especially under natural circulation conditions, is thus complicated. This paper focuses on the development of a butterfly check valve model to enhance the capability of the thermal–hydraulic system code and the developed model is implemented into the RELAP5 code. Both steady-state calculations and transient calculations were carried out for the primary loop system of a marine nuclear power plant and the calculation results are compared with the experimental data for verification purpose. The simulation results show an agreement with the experimental data

  17. Experimental investigation of the check valve behaviour when the flow is reversing

    Directory of Open Access Journals (Sweden)

    Himr D.

    2017-01-01

    Full Text Available Check valve in a pipeline is supposed to prevent the reverse flow and to allow the flow in the positive direction. The construction of check valves follows these requirements, but the check valve must not cause pressure pulsations in transients. It means when the fluid is accelerating or decelerating. The article describes an experimental investigation of a swing check valve when the flow is changing its direction. The check valve was placed in an experimental circuit, where the pressure on the upstream and downstream side of the valve was measured and the current value of flow rate was determined. The goal was to simulate conditions in the real system, where the check valve slam had been observed.

  18. Check valve slam caused by air intrusion in emergency cooling water system

    International Nuclear Information System (INIS)

    Martin, C.S.

    2011-01-01

    Waterhammer pressures were experienced during periodic starting of Residual Heat Removal (RHR) pumps at a nuclear plant. Prior to an analytical investigation careful analysis performed by plant engineers indicated that the spring effect of entrapped air in a heat exchanger resulted in water hammer due to check valve slam following flow reversal. In order to determine in more detail the values of pertinent parameters controlling this water hammer a hydraulic transient analysis was performed of the RHR piping system, including essential elements such as the pump, check valve, and heat exchanger. Using characteristic torque and pressure loss curves the motion of the check valve was determined. By comparing output of the water hammer analysis with site recordings of pump discharge pressure the computer model was calibrated, allowing for a realistic estimate of the quantity of entrapped air in the heat exchanger. (author)

  19. Acoustic emission condition monitoring of a nuclear power plant check valve using artificial neural networks

    International Nuclear Information System (INIS)

    Lee, Joon Hyun; Lee, Min Rae; Kim, Jung Teak

    2005-01-01

    In this study, an advanced condition monitoring technique based on acoustic emission (AE) detection and artificial neural networks was applied to a check valve, one of the components being used extensively in a safety system of a nuclear power plant (Npp). AE testing for a check valve under controlled flow loop conditions was performed to detect and evaluate disk movement for valve degradation such as wear and leakage due to foreign object interference in a check valve. It is clearly demonstrated that the evaluation of different types of failure modes such as disk wear and check valve leakage were successful by systematically analyzing the characteristics of various AE parameters. It is also shown that the leak size can be determined with an artificial neural network

  20. A review of historical check valve failure data

    International Nuclear Information System (INIS)

    Casada, D.A.; Todd, M.D.

    1992-01-01

    Check valve operating problems in recent years have resulted in significant operating transients, increased cost, and decreased system availability. In response, additional attention has been given to check valves by utilities, as well as the US Nuclear Regulatory Commission (NRC) and the American Society of Mechanical Engineers Operation and Maintenance Committee. All these organizations have the fundamental goal of ensuring reliable operation of check valves. A key ingredient of an engineering-oriented reliability improvement effort is a thorough understanding of relevant historical experience. Oak Ridge National Laboratory is currently conducting a detailed review of historical failure data available through the Institute of Nuclear Power Operation's Nuclear Plant Reliability Data System. The focus of the review is on check valve failures that have involved significant degradation of the valve internal parts. A variety of parameters are being considered during the review, including size, age, system of service, method of failure discovery, the affected valve parts, attributed causes, and corrective actions. This work is being carried out under the auspices of the NRC's Nuclear Plant Aging Research program. At this time, the study is approximately 50% complete. All failure records have been reviewed and categorized, and preliminary tabulation and correlation of data is underway. The bulk of the tabulation and correlation portion of the work is expected to be completed by the end of June 1992. A report draft is expected in the fall of 1992

  1. SOLA-LOOP analysis of a back pressure check valve

    International Nuclear Information System (INIS)

    Travis, J.R.

    1984-01-01

    The SOLA-LOOP computer code for transient, nonequilibrium, two-phase flows in networks has been coupled with a simple valve model to analyze a feedwater pipe breakage with a back-pressure check valve. Three tests from the Superheated Steam Reactor Safety Program Project (PHDR) at Kahl, West Germany, are analyzed, and the calculated transient back-pressure check valve behavior and fluid dynamics effects are found to be in excellent agreement with the experimentally measured data

  2. Development of a stainless steel check valve for cryogenic applications

    NARCIS (Netherlands)

    Veenstra, T.T.; Venhorst, G.C.F.; Venhorst, G.C.F.; Burger, Johannes Faas; Holland, Herman J.; ter Brake, Hermanus J.M.; Sirbi, A.; Rogalla, Horst

    2007-01-01

    This paper describes the development of a check valve for use in a sorption compressor that will drive a 10 mW 4.5 K Joule–Thomson cryocooler. For the check valve extremely low backflow rates are tolerable at an operating temperature of the valve of 50 K. To fulfill these requirements, the sealing

  3. Overview of Prevention for Water Hammer by Check Valve Action in Nuclear Reactor

    International Nuclear Information System (INIS)

    Kim, Dayong; Yoon, Hyungi; Seo, Kyoungwoo; Kim, Seonhoon

    2016-01-01

    Water hammer can cause serious damage to pumping system and unexpected system pressure rise in the pipeline. In nuclear reactor, water hammer can influence on the integrity of safety related system. Water hammer in nuclear reactor have been caused by voiding in normally water-filled lines, steam condensation line containing both steam and water, as well as by rapid check valve action. Therefore, this study focuses on the water hammer by check valve among the sources of water hammer occurrence and suggests proper methodology for check valve type selection against water hammer. This study focuses on the water hammer by check valve action among the sources of water hammer occurrence and suggests proper methodology for check valve type selection against water hammer. If the inadvertent pump trip or pipe rupture in high velocity and pressure pipe is predicted, the fast response check valve such as tiled disc, dual disc and nozzle check valve should be installed in the system. If the inadvertent pump trip or pipe rupture in very high velocity and pressure pipe and excessively large revered flow velocity are predicted, the very slowly closing check valve such as controlled closure check valve should be installed in the system

  4. Overview of Prevention for Water Hammer by Check Valve Action in Nuclear Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dayong; Yoon, Hyungi; Seo, Kyoungwoo; Kim, Seonhoon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Water hammer can cause serious damage to pumping system and unexpected system pressure rise in the pipeline. In nuclear reactor, water hammer can influence on the integrity of safety related system. Water hammer in nuclear reactor have been caused by voiding in normally water-filled lines, steam condensation line containing both steam and water, as well as by rapid check valve action. Therefore, this study focuses on the water hammer by check valve among the sources of water hammer occurrence and suggests proper methodology for check valve type selection against water hammer. This study focuses on the water hammer by check valve action among the sources of water hammer occurrence and suggests proper methodology for check valve type selection against water hammer. If the inadvertent pump trip or pipe rupture in high velocity and pressure pipe is predicted, the fast response check valve such as tiled disc, dual disc and nozzle check valve should be installed in the system. If the inadvertent pump trip or pipe rupture in very high velocity and pressure pipe and excessively large revered flow velocity are predicted, the very slowly closing check valve such as controlled closure check valve should be installed in the system.

  5. Reliability estimation for check valves and other components

    International Nuclear Information System (INIS)

    McElhaney, K.L.; Staunton, R.H.

    1996-01-01

    For years the nuclear industry has depended upon component operational reliability information compiled from reliability handbooks and other generic sources as well as private databases generated by recognized experts both within and outside the nuclear industry. Regrettably, these technical bases lacked the benefit of large-scale operational data and comprehensive data verification, and did not take into account the parameters and combinations of parameters that affect the determination of failure rates. This paper briefly examines the historic use of generic component reliability data, its sources, and its limitations. The concept of using a single failure rate for a particular component type is also examined. Particular emphasis is placed on check valves due to the information available on those components. The Appendix presents some of the results of the extensive analyses done by Oak Ridge National Laboratory (ORNL) on check valve performance

  6. A planar PDMS micropump using in-contact minimized-leakage check valves

    International Nuclear Information System (INIS)

    Ni, Junhui; Li, Beizhi; Huang, Fengliang; Wang, Bin; Lin, Qiao

    2010-01-01

    We present a micropump with a simple planar design featuring compliant in-contact check valves in a single layer, which allows for a simple structure and easy system integration. The micropump, based on poly(dimethylsiloxane) (PDMS), primarily consists of a pneumatically driven thin membrane, a pump chamber, and two in-plane check valves. The pair of check valves is based on an in-contact flap–stopper configuration and is able to minimize leakage flow, greatly enhancing the reliability and performance of the micropump. Systematic experimental characterization of the micropump has been performed in terms of the frequency response of the pumping flow rate with respect to factors including device geometry (e.g. chamber height) and operating parameters (e.g. pneumatic driving pressure and backpressure). The results demonstrate that this micropump is capable of reliably generating a maximum flow rate of 41 µL min −1 and operating against a high backpressure of up to 25 kPa. In addition, a lumped-parameter theoretical model for the planar micropump is also developed for accurate analysis of the device behavior. These results demonstrate the capability of this micropump for diverse applications in lab-on-a-chip systems.

  7. Optimization analysis of swing check valve closing induced water hammer

    International Nuclear Information System (INIS)

    Han Wenwei; Han Weishi; Guo Qing; Wang Xin; Liu Chunyu

    2014-01-01

    A mathematical-physics model of double pump parallel feed system was constructed. The water hammer was precisely calculated, which was formed in the closing process of swing check valve. And a systematic analysis was carried out to determine the influence of the torques from both valve plate and damping torsion spring on the valve closing induced water hammer. The results show that the swing check valve would distinctly produce the water hammer during the closing procedure in the double pump parallel feed water system. The torques of the valve plate can partly reduce the water hammer effect, and implying appropriate materials of valve plate and appropriate spring can effectively relieve the harm of water hammer. (authors)

  8. The development of fusion sensor techniques for condition monitoring of a check valve

    International Nuclear Information System (INIS)

    Seong, S.H.; Kim, J.S.; Hur, S.; Kim, J.T.; Park, W.M.; Cha, D.B.

    2004-01-01

    The failures of check valves are one of the most important problems in nuclear power plants because the reverse flows through the failed check valve impact on the healthy hydraulic loop. The present test method of finding out the mechanical failure of a check valve is very risky in the radiated environments during normal operation. In addition, the detection of failures in the overhaul period is very costly and tedious because many check valves are used in the plants and manual disassembly work is required. We have suggested the fusion sensor technology for detecting the failures of check valves through measuring and analyzing the backward leakage flow and mechanical vibration without disassembling the check valve. The fusion sensor means that more than two sensors are used in order to identify and analyze the changes of the frequency response between the failed check valve and healthy check valve. We use the accelerometer and acoustic emission sensor as an alternative to the fusion sensor methodology. We have found that the acoustic emission sensor would be capable of directly detecting a high frequency acoustic wave generated from backward leakage flow itself at a low pressure and temperature. The accelerometer for detecting the mechanical vibration induced from leakage flows would, also, be useful at a high pressure and temperature from the previous studies. The effectiveness of this system is that it is possible for predictive maintenance and information of the problem valve will be captured and it reduces the radiation exposure for the maintenance personnel during power operation as well as the maintenance period. (orig.)

  9. A characterization of check valve degradation and failure experience in the nuclear power industry: 1991 Failures, Volume 2

    International Nuclear Information System (INIS)

    McElhaney, K.L.

    1995-07-01

    Review and characterization of check valve failures taken from the Institute of Nuclear Power Operation's Nuclear Plant Reliability Data System was performed in accordance with part two of a three-phase project sponsored by the US Nuclear Regulatory Commission. The analysis was performed for check valve failures occurring in 1991 and is intended to update the previous analysis performed for the time period 1984--1990. To maintain consistency and for ease of the 1991 analysis presents the same parameters and cross-correlations in essentially the same format as the 1984--1990 study. Additional data was obtained for the 1991 analysis, including information related to specific check valve type. This information is presented in a separate section of the report

  10. A characterization of check valve degradation and failure experience in the nuclear power industry

    International Nuclear Information System (INIS)

    Casada, D.A.; Todd, M.D.

    1993-09-01

    Check valve operating problems in recent years have resulted in significant operating transients, increased cost and decreased system availability. As a result, additional attention has beau given to check valves by utilities (resulting in the formation of the Nuclear Industry Check Valve Group), as well as the US Nuclear Regulatory Commission and the American Society of Mechanical Engineers Operation and Maintenance Committee. All these organizations have the fundamental goal of ensuring reliable operation of check valves. A key ingredient to an engineering-oriented reliability improvement effort is a thorough understanding of relevant historical experience. A detailed review of historical failure data, available through the Institute of Nuclear Power Operation's Nuclear Plant Reliability Data System, has been conducted. The focus of the review is on check valve failures that have involved significant degradation of the valve internal parts. A variety of parameters are considered, including size, age, system of service, method of failure discovery, the affected valve parts, attributed causes, and corrective actions

  11. Condition monitoring of a check valve for nuclear power plants by means of acoustic emission technique

    International Nuclear Information System (INIS)

    Lee, Min Rae; Leee, Jun Hyun; Kim, Jung Tack; Kim, Jung Soo; Luk, V. K.

    2003-01-01

    This work performed in support of the International Nuclear Energy Research Initiative(INERI) program, which was to develop and demonstrate advanced sensor and computational technology for on-line monitoring of the condition of components, structures, and systems in advanced and next-generation nuclear power plants (NPPs). The primary object of this work is to investigate advanced condition monitoring systems based on acoustic emission detection that can provide timely detection of check valve degradation and service aging so that maintenance/replacement could be preformed prior to loss of safety function. The research is focused on the capability of AE technique to provide diagnostic information useful in determining check valve aging and degradation, check valve failures and undesirable operating modes. This work also includes the investigation and adaptation of several advanced sensor technologies such as accelerometer and advanced ultrasonic technique. In addition, this work will develop advanced sophisticated signal processing, noise reduction, and pattern recognition techniques and algorithms from check valve degradation.

  12. Condition monitoring of a check valve for nuclear power plants by means of acoustic emission technique

    International Nuclear Information System (INIS)

    Lee, M. R.; Lee, J. H.; Kim, J. T.; Kim, J. S.; Luk, V. K.

    2003-01-01

    This work performed in support of the International Nuclear Energy Research Institute (INERI) program, which was to develop and demonstrate advanced sensor and computational technology for on-line monitoring of the condition of components, structures, and systems in advanced and next-generation nuclear power plants (NPPs). This primary object of this work is to investigate advanced condition monitoring systems based on acoustic emission detection that can provide timely detection of check valve degeneration and service aging so that maintenance/replacement could be preformed prior to loss safety function. The research is focused on the capability of AE technique to provide diagnostic information useful in determining check valve aging and degradation check valve failure and undesirable operating modes. This work also includes the investigation and adaptation of several advanced sensor technologies such as accelerometer and advanced ultrasonic technique. In addition, this work will develop advanced sophisticated signal processing, noise reduction, and pattern recognition techniques and algorithms from check valve degradation.

  13. A study on the optimization of test interval for check valves of Ulchin Unit 3 using the risk-informed in-service testing approach

    International Nuclear Information System (INIS)

    Kang, D. I.; Kim, K. Y.; Yang, Z. A.; Ha, J. J.

    2002-01-01

    We optimized the test interval for check valves of Ulchin Unit 3 using the risk-informed in-service testing (IST) approach. First, we categorized the IST check valves for Ulchin Unit 3 according to their contributions to the safety of Ulchin Unit 3. Next, we performed the risk analysis on the relaxation of test interval for check valves identified as relatively low important to the safety of Ulchin Unit 3 to identify the maximum increasable test interval of them. Finally, we estimated the number of tests of IST check valves to be performed due to the changes of test interval. These study results are as follows: The categorization of IST check valve importance; the number of the HSSCs is 24(11.48%), the ISSCs is 40 (19.14%), and the LSSCs is 462(69.38%). The maximum increasable test interval; 6 times of current test interval of ISSCs2 and 40 times of that of LSSCs. The number of tests of IST check valves to be performed during 6 refueling time can be reduced from 7692 to 1333 ( 82.7%)

  14. Experimental and analytical studies on waterhammer generated by the closing of check valves

    International Nuclear Information System (INIS)

    Huet, J.L.; Garcia, J.L.; Coppolani, P.; Ziegler, B.

    1987-01-01

    A double-guillotine rupture on a water line upstream from a check valve generates a severe transient between the check valve and the pressure vessel on the downstream side. Successively following phenomena occur: - decrease then reversal of the flow, - closing of the check valve with impact of the plug on its seat, - waterhammer propagating in the pipe downstream from the check valve. The COMMISARIAT A L'ENERGIE ATOMIQUE (C.E.A.) FRAMATOME and ELECTRICITE DE FRANCE (E.D.F.) have undertaken a joint program in order to: - investigate the behavior uf the check valve in the event of a sudden closure, - evaluate the pressure and flow transient in the line. The program includes: - full scale tests in two loops, CLAUDIA (C.E.A.) and ECLAIR (E.D.F.), - analytical studies in order to qualify the calculation codes. This paper describes the experimental program and presents the analysis results for a benchmark test

  15. Model based feasibility study on bidirectional check valves in wave energy converters

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Pedersen, Henrik C.; Andersen, Torben Ole

    2014-01-01

    Discrete fluid power force systems have been proposed as the primary stage for Wave Energy Converters (WEC’s) when converting ocean waves into electricity, this to improve the overall efficiency of wave energy devices. This paper presents a model based feasibility study of using bidirectional check....../Off and bidirectional check valves. Based on the analysis it is found that the energy production may be slightly improved by using bidirectional check valves as compared to on/off valves, due to a decrease in switching losses. Furthermore a reduction in high flow peaks are realised. The downside being increased...

  16. Space shuttle prototype check valve development

    Science.gov (United States)

    Tellier, G. F.

    1976-01-01

    Contaminant-resistant seal designs and a dynamically stable prototype check valve for the orbital maneuvering and reaction control helium pressurization systems of the space shuttle were developed. Polymer and carbide seal models were designed and tested. Perfluoroelastomers compatible with N2O4 and N2H4 types were evaluated and compared with Teflon in flat and captive seal models. Low load sealing and contamination resistance tests demonstrated cutter seal superiority over polymer seals. Ceramic and carbide materials were evaluated for N2O4 service using exposure to RFNA as a worst case screen; chemically vapor deposited tungsten carbide was shown to be impervious to the acid after 6 months immersion. A unique carbide shell poppet/cutter seat check valve was designed and tested to demonstrate low cracking pressure ( 2.0 psid), dynamic stability under all test bench flow conditions, contamination resistance (0.001 inch CRES wires cut with 1.5 pound seat load) and long life of 100,000 cycles (leakage 1.0 scc/hr helium from 0.1 to 400 psig).

  17. Techniques for the thermal/hydraulic analysis of LMFBR check valves

    International Nuclear Information System (INIS)

    Cho, S.M.; Kane, R.S.

    1979-01-01

    A thermal/hydraulic analysis of the check valves in liquid sodium service for LMFBR plants is required to provide temperature data for thermal stress analysis of the valves for specified transient conditions. Because of the complex three-dimensional flow pattern within the valve, the heat transfer analysis techniques for less complicated shapes could not be used. This paper discusses the thermal analysis techniques used to assure that the valve stress analysis is conservative. These techniques include a method for evaluating the recirculating flow patterns and for selecting appropriately conservative heat transfer correlations in various regions of the valve

  18. HDR-investigations of check valve closure and resultant water hammer effects

    International Nuclear Information System (INIS)

    Scholl, K.D.

    1983-01-01

    The presented investigations are based on the Loss of Coolant Accident (LOCA). They concentrate on the first blowdown phase after pipe break of a feedwater line. The effect of such a break is moderated by quick closing check valves, by which the loss of coolant water is reduced and optimal post accident conditions are obtained. Unfortunately the closure of the valve can cause high pressure peaks (water hammer effects) in the feedwater system which potentially could produce safety relevant secondary damage. The system loading by these effects has been analysed. The HDR-Investigation-results led to an improvement of the feedwater system safety by verifying damping measures of quick closing check valves. Pressure peaks obtained with undamped valves in the range of 300 bars, are reduced to zero or a few bars above the normal operation pressure in feedwater systems. For the analytical simulation of valve closure the following dominant acting forces are identified: the blowdown flow resistance of the valve cone and the damping pistong force. The analytical description and quantification of the forces depends on blowdown flow and valve friction parameters. These have been evaluated and are presented for practical use. (orig.)

  19. Light water reactor pressure isolation valve performance testing

    International Nuclear Information System (INIS)

    Neely, H.H.; Jeanmougin, N.M.; Corugedo, J.J.

    1990-07-01

    The Light Water Reactor Valve Performance Testing Program was initiated by the NRC to evaluate leakage as an indication of valve condition, provide input to Section XI of the ASME Code, evaluate emission monitoring for condition and degradation and in-service inspection techniques. Six typical check and gate valves were purchased for testing at typical plant conditions (550F at 2250 psig) for an assumed number of cycles for a 40-year plant lifetime. Tests revealed that there were variances between the test results and the present statement of the Code; however, the testing was not conclusive. The life cycle tests showed that high tech acoustic emission can be utilized to trend small leaks, that specific motor signature measurement on gate valves can trend and indicate potential failure, and that in-service inspection techniques for check valves was shown to be both feasible and an excellent preventive maintenance indicator. Life cycle testing performed here did not cause large valve leakage typical of some plant operation. Other testing is required to fully understand the implication of these results and the required program to fully implement them. (author)

  20. Simulation of the behaviour of a servo actuated check valve upon rupture of the feedwater pipe

    International Nuclear Information System (INIS)

    Lucas, A.M. de; Perezagua, R.L.; Rosa, B. de la; Sanz, J.

    1995-01-01

    The steam generator replacement programme at Almaraz NPP, provides for the installation of a replacement damped non-return valve for the feedwater system. the function of this valve is to protect the steam generator in the event of a rupture in the feedwater pipe. Sudden closure of the check valve, against the flow and following rupture of the feedwater pipe, causes overpressure in the valve which is transmitted to the steam generator nozzle. It is therefore necessary to know this when designing the internal systems of the steam generator. Using the RELAP5/MODE3 code, it has been possible to simulate the dynamic behaviour of a check valve upon rupture of a feedwater pipe postulated outside the containment. The calculation model has been applied to different types of check valve. (Author)

  1. CAPD Software Development for Automatic Piping System Design: Checking Piping Pocket, Checking Valve Level and Flexibility

    International Nuclear Information System (INIS)

    Ari Satmoko; Edi Karyanta; Dedy Haryanto; Abdul Hafid; Sudarno; Kussigit Santosa; Pinitoyo, A.; Demon Handoyo

    2003-01-01

    One of several steps in industrial plant construction is preparing piping layout drawing. In this drawing, pipe and all other pieces such as instrumentation, equipment, structure should be modeled A software called CAPD was developed to replace and to behave as piping drafter or designer. CAPD was successfully developed by adding both subprogram CHKUPIPE and CHKMANV. The first subprogram can check and gives warning if there is piping pocket in the piping system. The second can identify valve position and then check whether valve can be handled by operator hand The main program CAPD was also successfully modified in order to be capable in limiting the maximum length of straight pipe. By limiting the length, piping flexibility can be increased. (author)

  2. Development and Characterization a Single-Active-Chamber Piezoelectric Membrane Pump with Multiple Passive Check Valves.

    Science.gov (United States)

    Zhang, Ronghui; You, Feng; Lv, Zhihan; He, Zhaocheng; Wang, Haiwei; Huang, Ling

    2016-12-12

    In order to prevent the backward flow of piezoelectric pumps, this paper presents a single-active-chamber piezoelectric membrane pump with multiple passive check valves. Under the condition of a fixed total number of passive check valves, by means of changing the inlet valves and outlet valves' configuration, the pumping characteristics in terms of flow rate and backpressure are experimentally investigated. Like the maximum flow rate and backpressure, the testing results show that the optimal frequencies are significantly affected by changes in the number inlet valves and outlet valves. The variation ratios of the maximum flow rate and the maximum backpressure are up to 66% and less than 20%, respectively. Furthermore, the piezoelectric pump generally demonstrates very similar flow rate and backpressure characteristics when the number of inlet valves in one kind of configuration is the same as that of outlet valves in another configuration. The comparison indicates that the backflow from the pumping chamber to inlet is basically the same as the backflow from the outlet to the pumping chamber. No matter whether the number of inlet valves or the number of outlet valves is increased, the backflow can be effectively reduced. In addition, the backpressure fluctuation can be significantly suppressed with an increase of either inlet valves or outlet valves. It also means that the pump can prevent the backflow more effectively at the cost of power consumption. The pump is very suitable for conditions where more accurate flow rates are needed and wear and fatigue of check valves often occur.

  3. Development and Characterization a Single-Active-Chamber Piezoelectric Membrane Pump with Multiple Passive Check Valves

    Directory of Open Access Journals (Sweden)

    Ronghui Zhang

    2016-12-01

    Full Text Available In order to prevent the backward flow of piezoelectric pumps, this paper presents a single-active-chamber piezoelectric membrane pump with multiple passive check valves. Under the condition of a fixed total number of passive check valves, by means of changing the inlet valves and outlet valves’ configuration, the pumping characteristics in terms of flow rate and backpressure are experimentally investigated. Like the maximum flow rate and backpressure, the testing results show that the optimal frequencies are significantly affected by changes in the number inlet valves and outlet valves. The variation ratios of the maximum flow rate and the maximum backpressure are up to 66% and less than 20%, respectively. Furthermore, the piezoelectric pump generally demonstrates very similar flow rate and backpressure characteristics when the number of inlet valves in one kind of configuration is the same as that of outlet valves in another configuration. The comparison indicates that the backflow from the pumping chamber to inlet is basically the same as the backflow from the outlet to the pumping chamber. No matter whether the number of inlet valves or the number of outlet valves is increased, the backflow can be effectively reduced. In addition, the backpressure fluctuation can be significantly suppressed with an increase of either inlet valves or outlet valves. It also means that the pump can prevent the backflow more effectively at the cost of power consumption. The pump is very suitable for conditions where more accurate flow rates are needed and wear and fatigue of check valves often occur.

  4. Modelling and analysis of a compensator burst after a check valve slam with the pressure surge code DYVRO mod. 3

    International Nuclear Information System (INIS)

    Neuhaus, Thorsten; Schaffrath, Andreas

    2009-01-01

    In this contribution the analysis and calculation of a compensator burst after a pump start and check valve slam with the pressure surge code DYVRO mod. 3 are presented. The compensator burst occurred in the essential service water system (ESWS) of a pressurized water reactor (PWR) in a deviant operation mode. Due to lack of knowledge about the causes a systematic investigation has been performed by TUV NORD SysTec GmbH and Co. KG. The following scenario was identified as most likely: Because of maintenance a heat exchanger was shut off from the ESWS by a closed valve. Due to the hydrostatic pressure profile air had been sucked in through this leaky closed valve forming an air bubble. After the pump start the water was accelerated against the closed valve where the air bubble was compressed. The subsequent backflow resulted in a fast closing of a check valve and a pressure surge that caused the compensator burst. Calculations have been performed with the self developed and validated pressure surge computer code DYVRO mod. 3. The present paper is focussed on the modelling of the pipe system, the pump, the check valve and the behaviour of the air bubble as well as the simulation of the incident. The calculated maximum pressure in the ESWS is above 3 MPa, which is approx. four times higher than the design pressure of 0.7 MPa. This pressure increase has led most likely to the abrupt compensator failure. (author)

  5. Fast flux test facility primary sodium check valve

    International Nuclear Information System (INIS)

    Rabe, G.B.; Nash, C.F.

    1975-01-01

    The design and development of a tilting-disc check valve for the primary sodium coolant loop of the Fast Flux Test Facility is described. The demanding design requirements specified for this system dictated a design with unique features. These features, along with the structural design and analysis requirements and the testing program used to develop and justify the design, are described

  6. Check valve slam waterhammer in piping systems equipped with multiple parallel pumps

    International Nuclear Information System (INIS)

    Sponsel, J.; Bird, E.; Zarechnak, A.

    1993-01-01

    The low pressure safety injection system at the calvert cliff's plant is designed to provide cooling water to the reactor in the event of a postulated accident and for reactor cool-down and decay heat removal during normal maintenance and refueling. This system experienced repeated damage to the axial piping supports on the pump section and the discharge headers due to the check valve phenomenon. To determine the cause, testing was performed in both the LPSI and CCW systems

  7. Dynamic modelling of check valves in shipping terminals; Modelagem dinamica de valvulas de retencao em terminais maritimos

    Energy Technology Data Exchange (ETDEWEB)

    Pires, Luis F.G.; Barreto, Claudio V.; Sarmento, Renata C. [Pontificia Univ. Catolica do Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Mecanica. Nucleo de Simulacao Termohidraulica de Dutos (SIMDUT)

    2005-07-01

    As usual a shipping terminal contains a header and its diameter is smaller than the main pipeline diameter. This diameter reduction amplifies the effects caused by hydraulic transients. It was noticed during simulations that check valves without dynamic modeling may introduce some error in the maximum pressure results without a dynamic model approach. The current paper uses commercial pipeline simulation software to model the dynamic behavior of the check valves. It was studied the header diameter influence and how the check valve model type may change the maximum pressure in the pipeline. It was proved that even a pipeline that works with low pressure and small elevation drop needs a detailed valve modeling to prevent the calculation of unreal pressure values in the region with diameter reduction. (author)

  8. Method for estimating steam hammer effects on swing-check valves during closure

    International Nuclear Information System (INIS)

    Uram, E.M.

    1976-01-01

    Relationships are developed for estimating the disk impact velocity resulting from a free swing closure of swing-check valves in normal flow and for pipe rupture. They derive from a phase-plane solution of the differential equation for the disk motion that accounts for the nature of the valve pressure drop variation due to steam-hammer effects during closure. For closure in normal flow, the method presented has a more correct foundation than that given in reference where a constant, average valve pressure differential based upon the steady-state pressure drop for the total piping system (which has no real relationship to the steam-hammer-induced valve pressure changes during the closure transient) is used in the valve disk motion equation

  9. Some considerations on water-hammer and cavitation following the sudden closure of a check-valve

    International Nuclear Information System (INIS)

    Caumette, P.; Lott, M.

    1987-01-01

    The function of a no-return check-valve is to obturate a pipe when the current in it has a tendancy to revert: in normal operation the valve is maintained in open position by the flow and it closes, in case of flow-rate inversion, under the action of its own weight and of the hydrodynamic forces. At the precise time of closure, the stream most of the time is suddenly interrupted, which determines a water-hammer and the separation of a water column followed by other water-hammers. The authors analyze the movement of a swing check-valve before closure and the subsequent evolution of the fluid state

  10. Flow characteristics and performance evaluation of butterfly valves using numerical analysis

    International Nuclear Information System (INIS)

    Jeon, S Y; Shin, M S; Yoon, J Y

    2010-01-01

    The industrial butterfly valves have been applied to various fields that transport fluid in volume, especially water supply and drainage pipeline for flow control. The butterfly valves in various shapes are manufactured, but a fitting performance comparison is not made up. For this reason, we carried out numerical analysis of some kind of butterfly valves for water supply and drainage pipeline using commercial CFD code FLUENT, and made a comparative study of these results. Also, the flow coefficient, the loss coefficient, and pressure distribution of valves according to valve opening rate were compared each other and the influence of these design variables on valve performance were checked over. Through flow around the valve disk, such as pressure distribution, flow pattern, velocity vectors, and form of vortex, we grasped flow characteristics.

  11. Chemical Safety Alert: Shaft Blow-Out Hazard of Check and Butterfly Valves

    Science.gov (United States)

    Certain types of check and butterfly valves can undergo shaft-disk separation and fail catastrophically, even when operated within their design limits of pressure and temperature, causing toxic/flammable gas releases, fires, and vapor cloud explosions.

  12. Analysis of a postulated pipe rupture and subsequent check valve slam of a PWR feedwater line

    International Nuclear Information System (INIS)

    Chang, K.C.; Adams, T.M.

    1983-01-01

    System designs criteria employed in the design of pressurized water reactors (PWR) requires that, for a postulated instantaneous guillotine rupture anywhere in the steam generator feedwater system, no more than one steam generator can be allowed to blowdown. Feedwater systems in many PWR's consist of pipe lines running from the feedwater pumps into a common feedwater header then branching into each steam generator from the header. The feedwater piping to each steam generator contains swing check valves to prevent reverse flow from the steam generator. This activation of some or all of these check valves significantly complicates the system structural analysis in that not only the blowdown forces resulting from the postulated pipe rupture, but also the water hammer loads resulting from closure of the check valve at high reverse flow velocities must be considered. The loads resulting from system blowdown and check valve closure are axial in nature. Peak loads ranging from 130000 lbs. to 180000 lbs. are not uncommon and are layout dependent. The analysis and design to withstand this transient loading deviates from the usual feedwater line design in that supports are required along the piping axis in the direction normal to the usual seismic supports. A brief and general discussion of the methods employed in the generation of the thermal-hydraulic loadings is presented. However, the discussion emphasizes the piping and piping support structural design and analysis method and approaches used in evaluating a selected portion of such a feedwater system. (orig./RW)

  13. Modelling of coupled self-actuating safety, relief and damped check valve systems with the codes TRAC-PF1 and ROLAST

    International Nuclear Information System (INIS)

    Neumann, U.; Puzalowski, R.; Grimm, I.

    1985-01-01

    Numerical valve models for simulation of selfactuating safety valves and damped check valves are introduced for the computer programs TRAC-PF1 and ROLAST. As examples of application post-test calculations and stability analysis are given. (orig.)

  14. Water-hammer experimental set-up and water-hammer experimental study for new types of check valve applied to PWR

    International Nuclear Information System (INIS)

    Liu Hanxun.

    1985-01-01

    This paper describes a self-designed constant temperature water-hammer shock test rig with stainless steel loop in which deionized water is used as working medium. To conduct water-hammer shock simulation tests for the countercurrent phenomenon occurred in the process of shutting, stopping, parallelling and switching the coolant loops of nuclear reactor, a specially designed four-way switching valve and its pneumatic mechanism are used. Water-hammer experimental study is performed for two types of PWR's nonshock check valve with diameter of 150 mm and 200 mm simultaneously. Transient performance of the shock waves, magnitude of their peaks and durations of their fluctuation, is obtained. Some analyses for existing calculational method on water-hammer are made

  15. Dual Check Valve and Method of Controlling Flow Through the Same

    Science.gov (United States)

    Corallo, Roger (Inventor)

    2016-01-01

    A dual check valve includes, a housing having a cavity fluidically connecting three ports, a movable member movably engaged within the cavity from at least a first position occluding a first port of the three ports, a second position occluding a second port of the three ports, and a third position allowing flow between both the first port, the second port and a third port of the three ports.

  16. Valve monitoring ITI-MOVATS

    International Nuclear Information System (INIS)

    Moureau, S.

    1993-01-01

    ITI-MOVATS provides a wide range of test devices to monitor the performance of valves: motor operated gate or globe valve, butterfly valve, air operated valve, and check valve. The ITI-MOVATS testing equipment is used in the following three areas: actuator setup/baseline testing, periodic/post-maintenance testing, and differential pressure testing. The parameters typically measured with the MOVATS diagnostic system as well as the devices used to measure them are described. (Z.S.)

  17. Thermal-hydraulic analysis for changing feedwater check valve leakage rate testing methodology

    International Nuclear Information System (INIS)

    Fuller, R.; Harrell, J.

    1996-01-01

    The current design and testing requirements for the feedwater check valves (FWCVs) at the Grand Gulf Nuclear Station are established from original licensing requirements that necessitate extremely restrictive air testing with tight allowable leakage limits. As a direct result of these requirements, the original high endurance hard seats in the FWCVs were modified with elastomeric seals to provide a sealing surface capable of meeting the stringent air leakage limits. However, due to the relatively short functional life of the elastomeric seals compared to the hard seats, the overall reliability of the sealing function actually decreased. This degraded performance was exhibited by frequent seal failures and subsequent valve repairs. The original requirements were based on limited analysis and the belief that all of the high energy feedwater vaporized during the LOCA blowdown. These phenomena would have resulted in completely voided feedwater lines and thus a steam environment within the feedwater leak pathway. To challenge these criteria, a comprehensive design basis accident analysis was developed using the RELAP5/MOD3.1 thermal-hydraulic code. Realistic assumptions were used to more accurately model the post-accident fluid conditions within the feedwater system. The results of this analysis demonstrated that no leak path exists through the feedwater lines during the reactor blowdown phase and that sufficient subcooled water remains in various portions of the feedwater piping to form liquid water loop seals that effectively isolate this leak path. These results provided the bases for changing the leak testing requirements of the FWCVs from air to water. The analysis results also established more accurate allowable leakage limits, determined the real effective margins associated with the FWCV safety functions, and led to design changes that improved the overall functional performance of the valves

  18. Thermal-hydraulic analysis for changing feedwater check valve leakage rate testing methodology

    Energy Technology Data Exchange (ETDEWEB)

    Fuller, R.; Harrell, J.

    1996-12-01

    The current design and testing requirements for the feedwater check valves (FWCVs) at the Grand Gulf Nuclear Station are established from original licensing requirements that necessitate extremely restrictive air testing with tight allowable leakage limits. As a direct result of these requirements, the original high endurance hard seats in the FWCVs were modified with elastomeric seals to provide a sealing surface capable of meeting the stringent air leakage limits. However, due to the relatively short functional life of the elastomeric seals compared to the hard seats, the overall reliability of the sealing function actually decreased. This degraded performance was exhibited by frequent seal failures and subsequent valve repairs. The original requirements were based on limited analysis and the belief that all of the high energy feedwater vaporized during the LOCA blowdown. These phenomena would have resulted in completely voided feedwater lines and thus a steam environment within the feedwater leak pathway. To challenge these criteria, a comprehensive design basis accident analysis was developed using the RELAP5/MOD3.1 thermal-hydraulic code. Realistic assumptions were used to more accurately model the post-accident fluid conditions within the feedwater system. The results of this analysis demonstrated that no leak path exists through the feedwater lines during the reactor blowdown phase and that sufficient subcooled water remains in various portions of the feedwater piping to form liquid water loop seals that effectively isolate this leak path. These results provided the bases for changing the leak testing requirements of the FWCVs from air to water. The analysis results also established more accurate allowable leakage limits, determined the real effective margins associated with the FWCV safety functions, and led to design changes that improved the overall functional performance of the valves.

  19. Study of check valve slamming in a BWR feedwater system following a postulated pipe break

    International Nuclear Information System (INIS)

    Safwat, H.H.; Arastu, A.H.; Norman, A.

    1985-01-01

    This study deals with a swing check valve slamming due to a break at relatively short distance from the valve. Under this situation, substantial flashing occurs near the valve and the result of the study are subject to what is believed to be a conservative simplifying assumption, i.e., the hydrodynamic moment acting on the valve during the transient is represented by resultant moment due to the pressure differential across the valve. It is believed that vapor voids forming at the valve would actually reduce the disk impact velocities in comparison to those predicted under this simplifying assumption. A technique used to represent a double-ended break through hypothetical valves may have some influence on the results particularly for long break opening times. The study has yielded good insight to help understand the complex problem. The study has focused on some parameters and the reader may raise questions on the effects of other parameters. Nevertheless, the present study underlines the complexity facing analysts dealing with this transient using analytical methods. Though some experimental data are available, the authors believe that an experimental study (recognizing the complexity of the experimental setup and instrumentation), would be quite useful. It can provide answers to questions facing analysts dealing with this problem and thus avoid unnecessary conservatisms due to uncertainties in input data

  20. Impact characteristics for high-pressure large-flow water-based emulsion pilot operated check valve reverse opening

    Science.gov (United States)

    Liu, Lei; Huang, Chuanhui; Yu, Ping; Zhang, Lei

    2017-10-01

    To improve the dynamic characteristics and cavitation characteristics of large-flow pilot operated check valve, consider the pilot poppet as the research object, analyses working principle and design three different kinds of pilot poppets. The vibration characteristics and impact characteristics are analyzed. The simulation model is established through flow field simulation software. The cavitation characteristics of large-flow pilot operated check valve are studied and discussed. On this basis, high-pressure large-flow impact experimental system is used for impact experiment, and the cavitation index is discussed. Then optimal structure is obtained. Simulation results indicate that the increase of pilot poppet half cone angle can effectively reduce the cavitation area, reducing the generation of cavitation. Experimental results show that the pressure impact is not decreasing with increasing of pilot poppet half cone angle in process of unloading, but the unloading capacity, response speed and pilot poppet half cone angle are positively correlated. The impact characteristics of 60° pilot poppet, and its cavitation index is lesser, which indicates 60° pilot poppet is the optimal structure, with the theory results are basically identical.

  1. Component unavailability versus inservice test (IST) interval: Evaluations of component aging effects with applications to check valves

    International Nuclear Information System (INIS)

    Vesely, W.E.; Poole, A.B.

    1997-07-01

    Methods are presented for calculating component unavailabilities when inservice test (IST) intervals are changed and when component aging is explicitly included. The methods extend usual approaches for calculating unavailability and risk effects of changing IST intervals which utilize Probabilistic Risk Assessment (PRA) methods that do not explicitly include component aging. Different IST characteristics are handled including ISTs which are followed by corrective maintenances which completely renew or partially renew the component. ISTs which are not followed by maintenance activities needed to renew the component are also handled. Any downtime associated with IST, including the test downtime and the following maintenance downtime, is included in the unavailability evaluations. A range of component aging behaviors is studied including both linear and nonlinear aging behaviors. Based upon evaluations completed to date, pooled failure data on check valves show relatively small aging (e.g., less than 7% per year). However, data from some plant systems could be evidence for larger aging rates occurring in time periods less than 5 years. The methods are utilized in this report to carry out a range of sensitivity evaluations to evaluate aging effects for different possible applications. Based on the sensitivity evaluations, summary tables are constructed showing how optimal IST interval ranges for check valves can vary relative to different aging behaviors which might exist. The evaluations are also used to identify IST intervals for check valves which are robust to component aging effects. General insights on aging effects are also extracted. These sensitivity studies and extracted results provide useful information which can be supplemented or be updated with plant specific information. The models and results can also be input to PRAs to determine associated risk implications

  2. Fabrication of micro metallic valve and pump

    Science.gov (United States)

    Yang, Ming; Kabasawa, Yasunari; Ito, Kuniyoshi

    2010-03-01

    Fabrication of micro devices by using micro metal forming was proposed by the authors. We developed a desktop servo-press machine with precise tooling system. Precise press forming processes including micro forging and micro joining has been carried out in a progressive die. In this study, micro metallic valve and pump were fabricated by using the precise press forming. The components are made of sheet metals, and assembled in to a unit in the progressive die. A micro check-valve with a diameter of 3mm and a length of 3.2mm was fabricated, and the property of flow resistance was evaluated. The results show that the check valve has high property of leakage proof. Since the valve is a unit parts with dimensions of several millimeters, it has advantage to be adapted to various pump design. Here, two kinds of micro pumps with the check-valves were fabricated. One is diaphragm pump actuated by vibration of the diaphragm, and another is tube-shaped pump actuated by resonation. The flow quantities of the pumps were evaluated and the results show that both of the pumps have high pumping performance.

  3. Inkjet 3D printed check microvalve

    International Nuclear Information System (INIS)

    Walczak, Rafał; Adamski, Krzysztof; Lizanets, Danylo

    2017-01-01

    3D printing enables fast and relatively easy fabrication of various microfluidic structures including microvalves. A check microvalve is the simplest valve enabling control of the fluid flow in microchannels. Proper operation of the check valve is ensured by a movable element that tightens the valve seat during backward flow and enables free flow for forward pressure. Thus, knowledge of the mechanical properties of the movable element is crucial for optimal design and operation of the valve. In this paper, we present for the first time the results of investigations on basic mechanical properties of the building material used in multijet 3D printing. Specified mechanical properties were used in the design and fabrication of two types of check microvalve—with deflecting or hinge-fixed microflap—with 200 µ m and 300 µ m thickness. Results of numerical simulation and experimental data of the microflap deflection were obtained and compared. The valves were successfully 3D printed and characterised. Opening/closing characteristics of the microvalve for forward and backward pressures were determined. Thus, proper operation of the check microvalve so developed was confirmed. (technical note)

  4. Experience with valves for PHWR reactors

    International Nuclear Information System (INIS)

    Narayan, K.; Mhetre, S.G.

    1977-01-01

    Material specifications and inspection and testing requirements of the valves meant for use in nuclear reactors are mentioned. In the heavy water systems (both primary and moderator) of a PHWR type reactor, the valves used are gate valves, globe valves, diaphragm valves, butterfly valves, check valves and relief valves. Their locations and functions they perform in the Rajasthan Atomic Power Station Unit-1 are described. Experience with them is given. The major problems encountered with them have been : (1) leakage from the stem seals and body bonnet joint, (2) leakage due to failure of diaphragm and/or washout of the packing and (3) malfunctioning. Measures taken to solve these are discussed. Finally a mention has been made of improved versions of valves, namely, metal diaphragm valve and inverted relief valve. (M.G.B.)

  5. Small causes, big effects. For environment and sales: Check of thermostat valves in the internet; Kleine Ursache, grosse Wirkung. Zugunsten Umwelt und Umsatz: Thermostatventil-Check jetzt im Internet

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2008-04-15

    Fifty percent of all installed thermostat valves are assumed to be lacking in energy efficiency, according to the ''Optimus'' research report. Industry has reacted to this by developing a ThermostatCheck, which can be accessed in the internet by builder-owners and fitters. (orig.)

  6. Thermal fatigue behavior of valves

    International Nuclear Information System (INIS)

    Moinereau, D.; Scliffet, L.; Capion, J.C.; Genette, P.

    1991-01-01

    This paper reports that valves of pressurized water reactors are exposed to thermal shocks during transient operations. The numerous thermal shock tests performed on valves on the EDF test facilities have shown the sensibility of fillets and geometrical discontinuities to thermal fatigue: cracks can appear in those areas and grow through the valve body. Valves systems designated as level 1 must be designed to withstand fatigue up to the second isolation valve: the relevant rule is specified in the paragraph B 3500 of the French RCCM code. It is a simplified method which doesn't require finite element calculations. Many valve systems have been designed according to this rule and have been operated without accident. However, in one case, important cracks were found in the fillet of a check-valve after numerous thermal shocks. Calculation of the valve's behavior according to the RCCM code to estimate the fatigue damage resulting from thermal shocks led to a low damage factor, which doesn't agree with the experimental results. This was confirmed by new testings and showed the inadequacy of B 3500 rule for thermal transients. On this base a new rule is proposed to estimate fatigue damage resulting from thermal shocks. An experimental program has been realized to validate this rule. Axisymetrical analytical mock-ups with different geometries and one check-valve in austenitic stainless steel 316 L have been submitted to hot thermal shocks of 210 degrees C magnitude

  7. Gate valve performance prediction

    International Nuclear Information System (INIS)

    Harrison, D.H.; Damerell, P.S.; Wang, J.K.; Kalsi, M.S.; Wolfe, K.J.

    1994-01-01

    The Electric Power Research Institute is carrying out a program to improve the performance prediction methods for motor-operated valves. As part of this program, an analytical method to predict the stem thrust required to stroke a gate valve has been developed and has been assessed against data from gate valve tests. The method accounts for the loads applied to the disc by fluid flow and for the detailed mechanical interaction of the stem, disc, guides, and seats. To support development of the method, two separate-effects test programs were carried out. One test program determined friction coefficients for contacts between gate valve parts by using material specimens in controlled environments. The other test program investigated the interaction of the stem, disc, guides, and seat using a special fixture with full-sized gate valve parts. The method has been assessed against flow-loop and in-plant test data. These tests include valve sizes from 3 to 18 in. and cover a considerable range of flow, temperature, and differential pressure. Stem thrust predictions for the method bound measured results. In some cases, the bounding predictions are substantially higher than the stem loads required for valve operation, as a result of the bounding nature of the friction coefficients in the method

  8. NRC inspections of licensee activities to improve the performance of motor-operated valves

    International Nuclear Information System (INIS)

    Scarbrough, T.G.

    1992-01-01

    The NRC regulations require that components important to the safe operation of a nuclear power plant be treated in a manner that provides assurance of their proper performance. Despite these regulatory requirements, operating experience and research programs have raised concerns regarding the performance of motor-operated valves (MOVs) in nuclear power plants. In June 1990, the staff issued NUREG-1352, Action Plans for Motor-Operated Valves and Check Valves, which contains planned actions to organize the activities aimed at resolving the concerns about MOV performance. A significant task of the MOV action plan is the staff's review of the implementation of Generic Letter (GL) 89-10 (June 28, 1989), 'Safety-Related Motor-Operated Valve Testing and Surveillance,' and its supplements, by nuclear power plant licensees. The NRC staff has issued several supplements to GL 89-10 to provide additional guidance for use by licensees in responding to the generic letter. The NRC staff has conducted initial inspections of the GL 89-10 programs at most licensee facilities. This paper outlines some of the more significant findings of those inspections. For example, licensees who have begun differential pressure and flow testing have found some MOVs to require more thrust to operate than predicted by the standard industry equation with typical valve factors assumed in the past. The NRC staff has found weaknesses in licensee procedures for conducting the differential pressure and flow tests, the acceptance criteria for the tests in evaluating the capability of the MOV to perform its safety function under design basis conditions, and feedback of the test results into the methodology used by the licensee in predicting the thrust requirements for other MOVs. Some licensees have not made adequate progress toward resolving the MOV issue for their facilities within the recommended schedule of GL 89-10

  9. AREVA's innovative solutions for valve diagnostics and in-situ valve repair

    International Nuclear Information System (INIS)

    Damies, H.; Breitenberger, U.; Munoz, L.; Kostroun, F.

    2012-01-01

    Optimized maintenance strategies are a key aspect for safe and undisturbed plant operation. Innovative valve service solutions can support that in an efficient way. The ADAM®/SIPLUG® valve monitoring system allows full online monitoring of valves and actuators with automatic evaluation and assessment. Especially for safety-related and operation-related valves this provides valuable information on components condition to ensure proper function and contribute to optimization of maintenance strategies as well as effective maintenance performance. More than 25 years of experience in various plants worldwide show that application of ADAM®/SIPLUG® valve diagnostics solution leads to increased plant safety and availability. With the innovative AVARIS technology an in-situ valve repair is possible. It has the unique ability to conduct several steps in-situ, to maintain the sealing seat of gate or check valves. By applying AVARIS, the valve is restored in its original state, the system remains unchanged. Thus, all original documents remain valid and applicable. In comparison to previous procedures like cutting valves out of the pipeline and repairing hard facings or damaged seal seats in a separate workshop or alternatively replacement by a new valve body the new AVARIS technology avoids costs, risk and effort. (author)

  10. ICDE project report: collection and analysis of common-cause failure of check valves

    International Nuclear Information System (INIS)

    Theiss, Klaus; Hessel, Philippe; Werner, Wolfgang

    2003-05-01

    This report documents a study performed on the set of Common Cause Failure (CCF) events of Check Valves (CVs). The events studied here were derived from the International CCF Data Exchange (ICDE) database. Organizations from Canada, Finland, France, Germany, Netherlands, Sweden, Switzerland and the United States contributed with data to this data exchange. This study examines 94 CCF events of CVs reported in the ICDE database by tabulating the data and observing trends. The database contains general information about event attributes like root cause, coupling factor, detection method and corrective action taken. As part of this study, most of these events were reviewed in more detail and characterized by failure cause and failure symptom categories. The study itself begins with an overview of the entire data set in chapter 5. Charts are provided for each of the above-mentioned event attributes. This chapter forms the baseline for chapter 6. The intention of chapter 6 is to give the reader a deeper qualitative insight in the database content beyond that obtained from using the event coding only. Chapter 7 contains the summary of the study results and the conclusions derived from. Approximately 8% of all ICDE events of CVs were complete CCFs (all redundant components had failed). The number of partial CCF events (at least two of the redundant components failed) accounted for 24%. In the remaining 68% of the ICDE events, less than two components had failed completely, and the other components of the observed group only suffered from small defects, incipient degradation or were not affected at all. However, it was found that for more than 75% of the ICDE events the causal factors had a high probability to be shared by all the redundant components. 88 of the 94 reported ICDE events were reviewed in some more detail in Section 6 of this report with respect to failure causes, failure symptoms and failure mechanism. All events classified with a low 'shared cause factor

  11. Water hammer analysis. Dynamic simulation model check valve piston; Analisis del golpe de airete. Modelo de simulacion dinamica de valvula de retencion piston

    Energy Technology Data Exchange (ETDEWEB)

    Royo, B.; Valdes, R.

    2012-11-01

    This report contains the description and the results of the dynamic simulation model that has been developed to predict the behaviour of one of our lift check valve design. The aim of the model is not only to simulate the closing process of the valve and to product the magnitude of the water hammer effect that may appear immediately after the valve closing, but also to simulate several design version until obtain the optimum which further minimizes such effect. the input data used for this study ensure reliable results since they represent a real system. (Author)

  12. Reactor containment purge and vent valve performance experiments

    International Nuclear Information System (INIS)

    Hunter, J.A.; Steele, R.; Watkins, J.C.

    1985-01-01

    Three nuclear-designed butterfly valves typical of those used in domestic nuclear power plant containment purge and vent applications were tested. For a comparison of responses, two eight-inch nominal pipe size valves with differing internal design were tested. For extrapolation insights, a 24-inch nominal pipe size valve was also tested. The valve experiments were performed with various piping configurations and valve disc orientations to the flow, to simulate various installation options in field application. As a standard for comparing the effects of the installation options, testing was also performed in a standard ANSI test section. Test cycles were performed at inlet pressures of 5 to 60 psig, while monitoring numerous test parameters, such as the valve disc position, valve shaft torque, mass flow rate, and the pressure and temperature at multiple locations throughout the test section. An experimental data base was developed to assist in the evaluation of the current analytical methods and to determine the influence of inlet pressure, inlet duct geometry, and valve orientation to the flow media on valve torque requirements, along with any resulting limitations to the extrapolation methods. 2 refs., 15 figs

  13. Leakage characterization of a piloted power operated relief valve

    International Nuclear Information System (INIS)

    Ezekoye, L.I.; Hess, M.D.

    1995-01-01

    In Westinghouse Pressurized Water Reactors (PWRs), power operated relief valves (PORVs) are used to provide overpressure protection of the Pressurizer. The valves are fail closed globe valves which means that power is required to open the valves and, on loss of power, the valves close. There are two ways to operate the PORVs. The more common way is to directly couple the disc to an actuator via a disc-stem assembly. The type of design is not the object of this paper. The other and less common way of operating a PORV is by piloting the main valve such that the opening or closing of a pilot valve opens and closes the main valve. This is the design of interest. In most plants, the PORVs are installed with a water loop seal while in some plants no water loop seals are used. It is generally accepted that loop seal installation minimizes valve seat leakage. In non-loop seal installation, the valve seat is exposed to steam which increases the potential for seat leakage. This paper describes the results of some tests performed with nitrogen and steam to characterize the leakage potential of a pilot operated PORV. The test results were compared with seat leakage tests of check valves to provide insight on the leakage testing of pilot operated valves and check valves. The paper also compares the test data with leakage estimates using the ASME/ANSI OM Code guidance on valve leakage

  14. A check valve controlled laser-induced microjet for uniform transdermal drug delivery

    Science.gov (United States)

    Ham, Hwi-chan; Jang, Hun-jae; Yoh, Jack J.

    2017-12-01

    A narrow nozzle ejects a microjet of 150 μm in diameter with a velocity of 140 m/s a by the laser-induced bubble expansion in the designed injector. The pulsed form of the driving force at a period of 10 Hz from the connected Er:YAG laser makes it possible for multiple microjet ejections aimed at delivery of drugs into a skin target. The pulsed actuation of the microjet generation is however susceptible to the air leak which can cause the outside air to enter into the momentarily de-pressurized nozzle, leading to a significant reduction of the microjet speed during the pulsed administering of the drug. In the present study, we designed a ball-check valve injector which is less prone to an unwanted air build up inside the nozzle by controlling the nozzle pressure to remain above ambient pressure at all times. The new device is rigorously compared against the reported performance of the previous injector and has shown to maintain about 97% of the initial microjet speed regardless of the number of shots administered; likewise, the drug penetration depth into a porcine skin is improved to 1.5 to 2.25 times the previously reported penetration depths.

  15. A check valve controlled laser-induced microjet for uniform transdermal drug delivery

    Directory of Open Access Journals (Sweden)

    Hwi-chan Ham

    2017-12-01

    Full Text Available A narrow nozzle ejects a microjet of 150 μm in diameter with a velocity of 140 m/s a by the laser-induced bubble expansion in the designed injector. The pulsed form of the driving force at a period of 10 Hz from the connected Er:YAG laser makes it possible for multiple microjet ejections aimed at delivery of drugs into a skin target. The pulsed actuation of the microjet generation is however susceptible to the air leak which can cause the outside air to enter into the momentarily de-pressurized nozzle, leading to a significant reduction of the microjet speed during the pulsed administering of the drug. In the present study, we designed a ball-check valve injector which is less prone to an unwanted air build up inside the nozzle by controlling the nozzle pressure to remain above ambient pressure at all times. The new device is rigorously compared against the reported performance of the previous injector and has shown to maintain about 97% of the initial microjet speed regardless of the number of shots administered; likewise, the drug penetration depth into a porcine skin is improved to 1.5 to 2.25 times the previously reported penetration depths.

  16. Design and performance characteristic analysis of servo valve-type water hydraulic poppet valve

    International Nuclear Information System (INIS)

    Park, Sung Hwan

    2009-01-01

    For water hydraulic system control, the flow or pressure control using high-speed solenoid valve controlled by PWM control method could be a good solution for prevention of internal leakage. However, since the PWM control of on-off valves cause extensive flow and pressure fluctuation, it is difficult to control the water hydraulic actuators precisely. In this study, the servo valve-type water hydraulic valve using proportional poppet as the main valve is designed and the performance characteristics of the servo valve-type water hydraulic valve are analyzed. Furthermore, it is demonstrated through experiments that a decline in control chamber pressure that follows the change of pilot flow is caused by the occurrence of cavitation around the proportional poppet, and that fundamental characteristics of the developed valve remain unaffected by the occurrence of cavitation

  17. Testing of cobalt-free alloys for valve applications using a special test loop

    International Nuclear Information System (INIS)

    Benhamou, C.

    1992-01-01

    Considering that use of cobalt alloys should be avoided as far as possible in PWR components, a programme aimed at establishing the performance of cobalt-free alloys has been performed for valve applications, where cobalt alloys are mainly used. Referring to past work, two types of cobalt-free alloys were selected: Ni-Cr-B-Si and Ni-Cr-Fe alloys. Cobalt-free valves' behaviour has been evaluated comparatively with cobalt valves by implementation of a programme in a special PWR test loop. At the issue of the loop test programme, which included endurance, thermal shock and erosion tests, cobalt-free alloys candidate to replace cobalt alloys are proposed in relation with valve type (globe valve and swing check valve). The following was established: (i) Colmonoy 4-26 (Ni-Cr-B-Si alloy) and Cenium Z20 (Ni-Cr-Fe alloy) deposited by plasma arc process were found suitable for use in 3inch swing check valves; (ii) for integral parts acting as guide rings, Nitronic 60 and Cesium Z20/698 were tested successfully; (iii) for small-bore components such as 2inch globe valves, no solution can yet be proposed; introduction of cobalt-free alloys is dependent on the development of automatic advanced arc surfacing techniques applied to small-bore components

  18. Preliminary assessment of valve IST effectiveness

    International Nuclear Information System (INIS)

    Grove, E.; DiBiasio, A.; Carbonaro, J.

    1994-01-01

    A preliminary review of inservice testing effectiveness for Code Class 1,2, and 3 valves at nuclear power plants was performed. These requirements are specified by the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section XI, and the Operations and Maintenance Standard. The Institute of Nuclear Power Operations Nuclear Plant Reliability Data System (NPRDS) database was used to provide failure reports for these components for 1988 to 1992. This time period coincides with the issuance of Generic Letter 89-04, which resulted in a more consistent application of the requirements by the licensees. For this time period, 8,593 valve failures were identified. From the review of the NPRDS database, the primary failure causes and failure modes for motor-operated valves (MOV), air-operated valves (AOV), and check valves (CV) were identified. Solenoid-operated valves were not reviewed in this study. Plant testing programs were effective in identifying approximately 60% of the CV failures, 46% of the AOV failures, and 44% of the MOV failures

  19. Experimental study for flow characteristics and performance evaluation of butterfly valves

    International Nuclear Information System (INIS)

    Kim, C K; Shin, M S; Yoon, J Y

    2010-01-01

    The industrial butterfly valves have been applied to transport a large of fluid with various fields of industry. Also, these are mainly used a control of fluid flux to the water and waste-water pipeline. Present, butterfly valves are manufacturing for multiplicity shape of bodies and discs with many producers. However, appropriate performance evaluation was not yet accomplished to compare about these valves through experiments. This study is performed the experiment of flow characteristics and performance of manufactured 400A butterfly valves for the water and waste pipeline, and compared experimental results. We performed experiments that were controlled fixed a differential pressure condition (1 psi) and the range of the flow rate conditions (500 m 3 /hr ∼ 2500 m 3 /hr), and also opened the disc of valves to a range of angle from 9 degree to 90 degree. We investigated and compared the valve flow coefficient and the valve loss coefficient of results through experiments with each butterfly valve.

  20. Plunger with simple retention valve

    International Nuclear Information System (INIS)

    Fekete, A.V.

    1987-01-01

    This patent describes a positive displacement retention valve apparatus in which the actual flow equals the theoretical maximum flow through the retention valve. The apparatus includes, in combination, a confined fluid flow conduit, a piston adapted for reciprocal movement within the fluid flow conduit between upstream and downstream limit positions, piston reciprocating means, and pressure responsive check valve means located upstream with respect to the piston in the fluid flow conduit. The pressure responsive check valve means operable to permit fluid flow therethrough in a downstream direction toward the piston, and to preclude fluid flow therethrough in an opposite direction. The piston is composed of parts which are relatively movable with respect to one another. The piston includes a simple retention valve consisting of a plug means, a cylinder having a minimum and a maximum internal cross section flow area therein and being reciprocal within the confined fluid flow conduit, and a seat on the cylinder for the plug means. The piston reciprocating means are operatively connected to the plug means

  1. A high performance magnetorheological valve with a meandering flow path

    International Nuclear Information System (INIS)

    Imaduddin, Fitrian; Amri Mazlan, Saiful; Azizi Abdul Rahman, Mohd; Zamzuri, Hairi; Ubaidillah; Ichwan, Burhanuddin

    2014-01-01

    The huge developments in the field of magnetorheological (MR) fluid-based devices will have a great influence on the future of mechatronic applications due to the ease of interfacing between electronic controls and the mechanical components that they provide. Among various MR fluid-based devices, an MR valve would be particularly significant for the development of other devices, if it could be successfully achieved. One of the most challenging obstacles to MR valve development is the difficulty of achieving device miniaturization while, at the same time, improving the achievable performance. This study demonstrates a novel design for an MR valve, using the meandering flow path approach in order to increase the effective area so that the MR fluid can be regulated within a small-sized valve. The meandering flow path is formed by combining multiple annular, radial and orifice flow channels. In order to analyze the valve performance, a mathematical model of the proposed MR valve is derived and combined with numerical simulation using the finite element method, with the intention of predicting the achievable pressure drop that can be generated by the valve. The predicted MR valve performances are then experimentally evaluated using an oscillation-disturbed bypass hydraulic cylinder. The simulation results show that the proposed MR valve design could yield substantial pressure drop improvement, which is confirmed by the experiment

  2. Hardfacing and packings for improved valve performance

    International Nuclear Information System (INIS)

    Aikin, J.A.; Patrick, J.N.F.; Inglis, I.

    2003-01-01

    The CANDU Owners Group (COG), Chemistry, Materials and Components (CMC) Program has supported an ongoing program on valve maintenance and performance for several years. An overview is presented of recent work on iron-based hardfacing, packing qualification, friction testing of polytetrafluoroethylene (PTFE) packings, and an investigation of re-torquing valve packing. Based on this program, two new valve-packing materials have been qualified for use in CANDU stations. By doing this, CANDU maintenance can avoid having only one packing qualified for station use, as well as assess the potential impact of the industry trend towards using lower gland loads. The results from corrosion tests by AECL and the coefficient of friction studies at Battelle' s tribology testing facilities on Delcrome 910, an iron-based hardfacing alloy, indicate it is an acceptable replacement for Stellite 6 under certain conditions. This information can be used to update in-line valve purchasing specifications. The renewed interest in friction characteristics, and environmental qualification (EQ) of packing containing PTFE has resulted in a new test program in these areas. The COG-funded valve programs have resulted in modifications to design specifications for nuclear station in-line valves and have led to better maintenance practices and valve reliability. In the end, this means lower costs and cheaper electricity. (author)

  3. Performance and morphology of decellularized pulmonary valves implanted in juvenile sheep.

    Science.gov (United States)

    Quinn, Rachael W; Hilbert, Stephen L; Bert, Arthur A; Drake, Bill W; Bustamante, Julie A; Fenton, Jason E; Moriarty, Sara J; Neighbors, Stacy L; Lofland, Gary K; Hopkins, Richard A

    2011-07-01

    Because of cryopreserved heart valve-mediated immune responses, decellularized allograft valves are an attractive option in children and young adults. The objective of this study was to investigate the performance and morphologic features of decellularized pulmonary valves implanted in the right ventricular outflow tract of juvenile sheep. Right ventricular outflow tract reconstructions in juvenile sheep (160±9 days) using cryopreserved pulmonary allografts (n=6), porcine aortic root bioprostheses (n=4), or detergent/enzyme-decellularized pulmonary allografts (n=8) were performed. Valve performance (echocardiography) and morphologic features (gross, radiographic, and histologic examination) were evaluated 20 weeks after implantation. Decellularization reduced DNA in valve cusps by 99.3%. Bioprosthetic valves had the largest peak and mean gradients versus decellularized valves (p=0.03; p<0.001) and cryopreserved valves (p=0.01; p=0.001), which were similar (p=0.45; p=0.40). Regurgitation was minimal and similar for all groups (p=0.16). No cusp calcification was observed in any valve type. Arterial wall calcification was present in cryopreserved and bioprosthetic grafts but not in decellularized valves. No autologous recellularization or inflammation occurred in bioprostheses, whereas cellularity progressively decreased in cryopreserved grafts. Autologous recellularization was present in decellularized arterial walls and variably extending into the cusps. Cryopreserved and decellularized graft hemodynamic performance was comparable. Autologous recellularization of the decellularized pulmonary arterial wall was consistently observed, with variable cusp recellularization. As demonstrated in this study, decellularized allograft valves have the potential for autologous recellularization. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  5. Midterm performance of a novel restorative pulmonary valved conduit: preclinical results

    NARCIS (Netherlands)

    Soliman, Osama I.; Miyazaki, Yosuke; Abdelghani, Mohammad; Brugmans, Marieke; Witsenburg, Maarten; Onuma, Yoshinobu; Cox, Martijn; Serruys, Patrick W.

    2017-01-01

    Aims: The Xeltis bioabsorbable pulmonary valved conduit (XPV), designed to guide functional restoration of patients' own tissue, is potentially more durable than current pulmonary bioprosthetic valves/valved conduits. The aim of this study was to assess the haemodynamic performance of the novel XPV

  6. Modification and performance evaluation of a mono-valve engine

    Science.gov (United States)

    Behrens, Justin W.

    A four-stroke engine utilizing one tappet valve for both the intake and exhaust gas exchange processes has been built and evaluated. The engine operates under its own power, but has a reduced power capacity than the conventional 2-valve engine. The reduction in power is traced to higher than expected amounts of exhaust gases flowing back into the intake system. Design changes to the cylinder head will fix the back flow problems, but the future capacity of mono-valve engine technology cannot be estimated. The back flow of exhaust gases increases the exhaust gas recirculation (EGR) rate and deteriorates combustion. Intake pressure data shows the mono-valve engine requires an advanced intake valve closing (IVC) time to prevent back flow of charge air. A single actuation camshaft with advanced IVC was tested in the mono-valve engine, and was found to improve exhaust scavenging at TDC and nearly eliminated all charge air back flow at IVC. The optimum IVC timing is shown to be approximately 30 crank angle degrees after BDC. The mono-valve cylinder head utilizes a rotary valve positioned above the tappet valve. The open spaces inside the rotary valveand between the rotary valve and tappet valve represent a common volume that needs to be reduced in order to reduce the base EGR rate. Multiple rotary valve configurations were tested, and the size of the common volume was found to have no effect on back flow but a direct effect on the EGR rate and engine performance. The position of the rotary valve with respect to crank angle has a direct effect on the scavenging process. Optimum scavenging occurs when the intake port is opened just after TDC.

  7. Effects of valve timing, valve lift and exhaust backpressure on performance and gas exchanging of a two-stroke GDI engine with overhead valves

    International Nuclear Information System (INIS)

    Dalla Nora, Macklini; Lanzanova, Thompson Diórdinis Metzka; Zhao, Hua

    2016-01-01

    Highlights: • Two-stroke operation was achieved in a four-valve direct injection gasoline engine. • Shorter valve opening durations improved torque at lower engine speeds. • The longer the valve opening duration, the lower was the air trapping efficiency. • Higher exhaust backpressure and lower valve lift reduced the compressor work. - Abstract: The current demand for fuel efficient and lightweight powertrains, particularly for application in downsized and hybrid electric vehicles, has renewed the interest in two-stroke engines. In this framework, an overhead four-valve spark-ignition gasoline engine was modified to run in the two-stroke cycle. The scavenging process took place during a long valve overlap period around bottom dead centre at each crankshaft revolution. Boosted intake air was externally supplied at a constant pressure and gasoline was directly injected into the cylinder after valve closure. Intake and exhaust valve timings and lifts were independently varied through an electrohydraulic valve train, so their effects on engine performance and gas exchanging were investigated at 800 rpm and 2000 rpm. Different exhaust backpressures were also evaluated by means of exhaust throttling. Air trapping efficiency, charging efficiency and scavenge ratio were calculated based on air and fuel flow rates, and exhaust oxygen concentration at fuel rich conditions. The results indicated that longer intake and exhaust valve opening durations increased the charge purity and hence torque at higher engine speeds. At lower speeds, although, shorter valve opening durations increased air trapping efficiency and reduced the estimated supercharger power consumption due to lower air short-circuiting. A strong correlation was found between torque and charging efficiency, while air trapping efficiency was more associated to exhaust valve opening duration. The application of exhaust backpressure, as well as lower intake/exhaust valve lifts, made it possible to increase

  8. Study on the Regulating Performance of Sliding Regulation-Valve

    Science.gov (United States)

    Hu, Wei; Peng, Xiaoyong; Zhang, Yuan; Zheng, Yulan; Zhu, Fangyao

    2018-01-01

    Using a proven reliable method of CFD to study the regulating performance of a sliding regulation valve with a conical spool and rugby body. The numerical simulation results indicate that no matter where the spool is located, the flow field always has a vortex at the center of the valve body; When the spool is at the origin, the vortex and resistance coefficient of the valve are the minimum; When the spool moves from the origin to the right (the opening of the valve becomes smaller) to reach a certain position later, vortex currents also begin to appear around the tube wall behind the orifice. In addition, the vortex increases as the throttling port decreases whereas the resistance coefficient of the valve ascends slowly with the increase of the deviation of the spool and the rise in series; This type of regulating valve has S type (slow at both ends, sensitive at the center) flow characteristics at the stroke, and is not affected by the size of Re.

  9. AVARIS. An innovative process to repair seal seat surfaces in gate and check valves

    International Nuclear Information System (INIS)

    Herzing, Karl-Heinz; Breitenberger, Ulf; Grieser, Armin

    2011-01-01

    AREVA Valve Repair in situ - AVARIS in short - is an innovative process for valve repair developed by AREVA. Its main benefit is that valves no longer need to be cut out but can be machined in situ, i.e. within the piping system. AVARIS saves the plant operators time and money, as complete exchanges of valves and the ensuing complex measures become dispensable. AVARIS is of high interest in the worldwide maintenance market, as it can be applied in both nuclear and conventional power plants. Moreover, AVARIS retrofits valves in the secondary and primary circuit which even saves complex nuclear transports. AVARIS fulfills the quality requirements of 3. party authorities in national and international markets. Valves repaired with AVARIS correspond to their original condition with regard to the sealing function. The successful first application on 2 gate valves in a German nuclear power plant proves that this repair technology is very reliable and flexible. Follow-up orders for AVARIS will be realized in several nuclear power plants in 2011. (orig.)

  10. The Actuator Fault Diagnosis Based on the Valve Friction

    Directory of Open Access Journals (Sweden)

    Jiajiang Li

    2014-08-01

    Full Text Available Control valve (actuator is the frequently moving terminal Instrument of the control system. To avoid the leaking of the actuator, there is packing at the moving parts. However, the friction caused by the packing can do harm to the control of the system. The washing effect of the media, high temperature, high pressure, frequent movement and other effects can result in the leaking of the packing and the deformation of the valve stem, which causes the change of the friction. The study of the control of the friction has always been an interesting topic in the industry. In this paper, we theoretically analyze the relationship of the friction of the packing and the static performance of the control valve, and offer a method to check the quality of the moving parts by attaching a strain gage (strain rosette to the empty part of the valve stem. This method has been demonstrated via experiment and a method to do error detection is provided at last.

  11. Fast Flux Test Facility primary sodium valves

    International Nuclear Information System (INIS)

    Rabe, G.B.; Ezra, B.C.

    1977-01-01

    The design and development of the valves used in the primary sodium coolant loop of the Fast Flux Test Facility is described. One tilting-disk check valve is used in the cold leg of the coolant loop. It is designed to limit flow reversal in the loop while maintaining a low pressure drop during forward flow. Two isolation valves are used in each coolant loop--one in the cold leg and one in the hot leg. They are of the motor-operated swinging-gate type. The design, analysis, and testing programs undertaken to develop and qualify these valves are described

  12. AVARIS. An innovative procedure to repair seal seats surfaces in gate and check valves

    International Nuclear Information System (INIS)

    Herzing, Karl-Heinz; Breitenberger, Ulf; Grieser, Armin

    2011-01-01

    AVARIS (AREVA Valve Repair In-Situ) saves the plant operators time and money, as complete exchanges of valves and all related elaborate consequences become dispensable. AVARIS is of high interest in the worldwide maintenance market, as it can be applied in both nuclear and conventional power plants. Moreover, AVARIS retrofits valves in the secondary and primary circuit which even saves complex nuclear transports. AVARIS fulfils the quality requirements of third party authorities in national and international markets. Valves repaired with AVARIS correspond to their original condition concerning sealing function. (orig.)

  13. Dynamic performance of self-operated three-way valve used in a hybrid air conditioner

    International Nuclear Information System (INIS)

    Zhang, Penglei; Zhou, Dehai; Shi, Wenxing; Li, Xianting; Wang, Baolong

    2014-01-01

    A hybrid air conditioner combining a thermosyphon cycle with a vapor compression refrigeration cycle has a large energy saving potential compared with a common air conditioner for spaces requiring year-round cooling. The performance of the switch between the vapor compression mode and the thermosyphon mode largely impacts the safety and reliability of hybrid air conditioners. Therefore, a self-operated three-way valve is proposed. A thermodynamic model and a kinetic model are developed in this paper to evaluate the dynamic performance of the switch valve. The effects of the spring force constant, compressor discharging volume, fit clearance and piston length on the dynamic performance of the switch valve are analyzed. In conclusion, the proposed self-operated three-way valve can realize the switch operation accurately. - Highlights: •A self-operated three-way valve is proposed for hybrid air conditioners. •The thermodynamic model and kinetic model of the self-operated three-way valve are developed. •The validity of models is verified by experiments. •Effects of four main design parameters on the operating performance of the valve are researched

  14. Aperture Valve for the Mars Organic Molecule Analyzer (MOMA)

    Science.gov (United States)

    Hakun, Claef F.; Engler, Charles D.; Barber, Willie E.; Canham, John S.

    2014-01-01

    NASA's participation in the multi-nation ExoMars 2018 Rover mission includes a critical astrobiology Mass Spectrometer Instrument on the Rover called the Mars Organic Molecule Analyzer (MOMA). The Aperture Valve is a critical electromechanical valve used by the Mass Spectrometer to facilitate the transfer of ions from Martian soil to the Mass Spectrometer for analysis. The MOMA Aperture Valve development program will be discussed in terms of the Initial valve design and subsequent improvements that resulted from prototype testing. The Initial Aperture Valve concept seemed promising, based on calculations and perceived merits. However, performance results of this design were disappointing, due to delamination of TiN and DLC coatings applied to the Titanium base metals, causing debris from the coatings to seize the valve. While peer reviews and design trade studies are important forums to vet a concept design, results from testing should not be underestimated.Despite the lack of development progress to meet requirements, valuable information from weakness discovered in the Initial Valve design was used to develop a second, more robust Aperture valve. Based on a check-ball design, the ETU flight valve design resulted in significantly less surface area to create the seal. Moreover, PVD coatings were eliminated in favor of hardened, nonmagnetic corrosion resistant alloys. Test results were impressive, with the valve achieving five orders of magnitude better sealing leak rate over end of life requirements. Cycle life was equally impressive, achieving 280,000 cycles without failure.

  15. Aggressive chemical decontamination tests on small valves from the Garigliano BWR

    International Nuclear Information System (INIS)

    Bregani, F.

    1990-01-01

    In order to check the effectiveness of direct chemical decontamination on small and complex components, usually considered for storage without decontamination because of the small amount, some tests were performed on the DECO experimental loop. Four small stainless steel valves from the primary system of the Garigliano BWR were decontaminated using mainly aggressive chemicals such as HC1, HF, HNO 3 and their mixtures. On two valves, before the treatment with aggressive chemicals, a step with soft chemical (oxalic and citric acid mixture) was performed in order to see whether a softening action enhances the following aggressive decontamination. Moreover, in order to increase as much as possible the decontamination effectiveness, a decontamination process using ultrasounds jointly with aggressive chemicals was investigated. After an intensive laboratory testing programme, two smaller stainless steel valves from the primary system of the Garigliano BWR were decontaminated using ultrasounds in aggressive chemical solutions

  16. Experimental investigation of the fluid dynamic efficiency of a high performance multi-valve internal combustion engine during the intake phase: Influence of valve-valve interference phenomena

    Directory of Open Access Journals (Sweden)

    Algieri Angelo

    2013-01-01

    Full Text Available The purpose of the present work is the analysis of the fluid dynamic behavior of a high performance internal combustion engine during the intake phase. In particular, a four-valve spark-ignition engine has been characterized at the steady flow rig. Dimensionless discharge coefficients have been used to define the global fluid dynamic efficiency of the intake system, while the Laser Doppler Anemometry (LDA technique has been employed to evaluate the mean flow in the valve curtain area and to characterise the interference phenomena between the two intake valves. The investigation has shown the significant influence of the valve lift on the volumetric efficiency of the intake apparatus. Moreover, the experimental analysis has highlighted that the valve-valve interference phenomena have a relevant impact on the head breathability, on the flow development within the combustion chamber and on the velocity standard deviations.

  17. RETRAN simulation of Oyster Creek MSIV closure and bypass valve tests

    International Nuclear Information System (INIS)

    Alammar, M.A.

    1987-01-01

    A series of benchmarks against start-up tests have been performed on the Oyster Creek boiling water reactor unit 2 RETRAN model in support of developing an in-house reload capability. The liquid and the pressure regulator models have been benchmarked against level and pressure setpoint changes, where small setpoint perturbations were made at rated power. The purpose of the present benchmark is to check the liquid level behavior during a severe level drop as during void collapse following a scram and to size the bypass valves by benchmarking the valves' contraction coefficient. The main steam isolation valves (MSIVs) closure start-up test was chosen for the former, while the bypass valve test was chosen for the latter. The two benchmarks complete the qualification of the upper downcomer liquid level for small and large level changes and the pressure regulator system for the Oyster Creek RETRAN model

  18. Industry activities to improve valve performance

    Energy Technology Data Exchange (ETDEWEB)

    Callaway, C.

    1996-12-01

    Motor-operated valve issues refuse to go away. For over a decade the industry and the NRC have been focusing extraordinary resources on assuring these special components operate when called upon. Now that industry has fixed the design deficiencies, it is focusing on assuring that they perform their safety function within the current licensing basis for the remainder of plant life. NEI supported the efforts by ASME to develop OMN-1 and was encouraged that the industry and the NRC worked together to develop risk and performance based approaches to maintain MOV performance.

  19. Performance evaluation of a piezoactuator-based single-stage valve system subjected to high temperature

    Science.gov (United States)

    Jeon, Juncheol; Han, Chulhee; Chung, Jye Ung; Choi, Seung-Bok

    2015-01-01

    In this paper, a novel single-stage valve system activated by a piezostack actuator is proposed and experimentally evaluated at both room temperature (20 °C) and high temperature (100 °C) conditions. A hinge-lever displacement amplifier is adopted in the valve system to magnify the displacement generated from the piezostack actuator. After explaining the operating principle of the proposed piezostack-driven single-stage valve system, the geometric dimensions and mechanical properties of the valve components are discussed in details. An experimental apparatus is then manufactured to evaluate the performances of the valve system such as flow rate. The experimental apparatus consists of a heat chamber, which can regulate the temperature of the valve system and oil, pneumatic-hydraulic cylinders, a hydraulic circuit, a pneumatic circuit, electronic devices, an interface card, and a high voltage amplifier. The pneumatic-hydraulic cylinder transforms the pneumatic pressure into hydraulic pressure. The performances of the valve system regarding spool response, pressure drop, and flow rate are evaluated and presented. In addition, the performance of the valve system under high temperature condition is compared with that under room temperature condition. The experimental results are plotted in both frequency and time domains.

  20. Performance evaluation of a piezoactuator-based single-stage valve system subjected to high temperature

    International Nuclear Information System (INIS)

    Jeon, Juncheol; Han, Chulhee; Ung Chung, Jye; Choi, Seung-Bok

    2015-01-01

    In this paper, a novel single-stage valve system activated by a piezostack actuator is proposed and experimentally evaluated at both room temperature (20 °C) and high temperature (100 °C) conditions. A hinge-lever displacement amplifier is adopted in the valve system to magnify the displacement generated from the piezostack actuator. After explaining the operating principle of the proposed piezostack-driven single-stage valve system, the geometric dimensions and mechanical properties of the valve components are discussed in details. An experimental apparatus is then manufactured to evaluate the performances of the valve system such as flow rate. The experimental apparatus consists of a heat chamber, which can regulate the temperature of the valve system and oil, pneumatic-hydraulic cylinders, a hydraulic circuit, a pneumatic circuit, electronic devices, an interface card, and a high voltage amplifier. The pneumatic-hydraulic cylinder transforms the pneumatic pressure into hydraulic pressure. The performances of the valve system regarding spool response, pressure drop, and flow rate are evaluated and presented. In addition, the performance of the valve system under high temperature condition is compared with that under room temperature condition. The experimental results are plotted in both frequency and time domains. (paper)

  1. Fiber heart valve prosthesis: influence of the fabric construction parameters on the valve fatigue performances.

    Science.gov (United States)

    Vaesken, Antoine; Heim, Frederic; Chakfe, Nabil

    2014-12-01

    Transcatheter aortic valve replacement (TAVR) has become today a largely considered alternative technique to surgical valve replacement in patients who are not operable or patients with high risk for open chest surgery. However, the biological valve tissue used in the devices implanted clinically appears to be fragile material when folded for low diameter catheter insertion purpose and released in calcified environment with irregular geometry. Textile polyester material is characterized by outstanding folding and strength properties combined with proven biocompatibility. It could thereof be considered to replace biological valve leaflets in the TAVR procedure. The textile construction parameters must however be tuned to obtain a material compatible with the valve requested durability. In that context, one issue to be addressed is the friction effect that occurs between filaments and between yarns within a fabric under flexure loading. This phenomenon could be critical for the resistance of the material on the long term. The purpose of the present work is to assess the fatigue performances of textile valve prototypes made from different fabric constructions (monofilament, multifilament, calendered mutifilament) under accelerated cyclic loading. The goal is to identify, which construction is the best suited to long term fatigue stress. Results show that calendered multifilament and monofilament fabric constructions undergo strong ruptures already from 40 Mio cycles, while non calendered multifilament appears more durable. The rupture patterns observed point out that durability is directly related to the flexure stiffness level of the fibrous elements in the construction. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Long-term performance of motor-operated valves

    Energy Technology Data Exchange (ETDEWEB)

    Scarbrough, T.G.

    1996-12-01

    The U.S. Nuclear Regulatory Commission (NRC) requires that motor-operated valves (MOVs) important to safety be designed, fabricated, erected, and tested to quality standards commensurate with the importance of the safety functions to be performed. Despite these requirements, operating experience and research revealed problems with the performance of MOVs in operating nuclear power plants. In response to the concerns about MOV performance, the NRC issued Generic Letter (GL) 89-10, {open_quotes}Safety-Related Motor-Operated Valve Testing and Surveillance,{close_quotes} and its supplements. Most licensees have completed the aspects of their GL 89-10 programs associated with the review of MOV design bases, verification of MOV switch settings initially, testing of MOVs under design-basis conditions where practicable, and improvement of evaluations of MOV failures and necessary corrective action. Licensees are establishing processes to ensure that the long-term aspects of their MOV programs, such as periodic verification of MOV capability and the trending of MOV problems, are maintained. The NRC staff is developing a generic letter to address periodic verification of MOV design-basis capability.

  3. Long-term performance of motor-operated valves

    International Nuclear Information System (INIS)

    Scarbrough, T.G.

    1996-01-01

    The U.S. Nuclear Regulatory Commission (NRC) requires that motor-operated valves (MOVs) important to safety be designed, fabricated, erected, and tested to quality standards commensurate with the importance of the safety functions to be performed. Despite these requirements, operating experience and research revealed problems with the performance of MOVs in operating nuclear power plants. In response to the concerns about MOV performance, the NRC issued Generic Letter (GL) 89-10, open-quotes Safety-Related Motor-Operated Valve Testing and Surveillance,close quotes and its supplements. Most licensees have completed the aspects of their GL 89-10 programs associated with the review of MOV design bases, verification of MOV switch settings initially, testing of MOVs under design-basis conditions where practicable, and improvement of evaluations of MOV failures and necessary corrective action. Licensees are establishing processes to ensure that the long-term aspects of their MOV programs, such as periodic verification of MOV capability and the trending of MOV problems, are maintained. The NRC staff is developing a generic letter to address periodic verification of MOV design-basis capability

  4. Performance Evaluation of a High Bandwidth Liquid Fuel Modulation Valve for Active Combustion Control

    Science.gov (United States)

    Saus, Joseph R.; DeLaat, John C.; Chang, Clarence T.; Vrnak, Daniel R.

    2012-01-01

    At the NASA Glenn Research Center, a characterization rig was designed and constructed for the purpose of evaluating high bandwidth liquid fuel modulation devices to determine their suitability for active combustion control research. Incorporated into the rig s design are features that approximate conditions similar to those that would be encountered by a candidate device if it were installed on an actual combustion research rig. The characterized dynamic performance measures obtained through testing in the rig are planned to be accurate indicators of expected performance in an actual combustion testing environment. To evaluate how well the characterization rig predicts fuel modulator dynamic performance, characterization rig data was compared with performance data for a fuel modulator candidate when the candidate was in operation during combustion testing. Specifically, the nominal and off-nominal performance data for a magnetostrictive-actuated proportional fuel modulation valve is described. Valve performance data were collected with the characterization rig configured to emulate two different combustion rig fuel feed systems. Fuel mass flows and pressures, fuel feed line lengths, and fuel injector orifice size was approximated in the characterization rig. Valve performance data were also collected with the valve modulating the fuel into the two combustor rigs. Comparison of the predicted and actual valve performance data show that when the valve is operated near its design condition the characterization rig can appropriately predict the installed performance of the valve. Improvements to the characterization rig and accompanying modeling activities are underway to more accurately predict performance, especially for the devices under development to modulate fuel into the much smaller fuel injectors anticipated in future lean-burning low-emissions aircraft engine combustors.

  5. Performance of balanced bellows safety relief valves

    International Nuclear Information System (INIS)

    Lai, Y.S.

    1992-01-01

    By the nature of its design, the set point and lift of a conventional spring loaded safety relief valve are sensitive to back pressure. One way to reduce the adverse effects of the back pressure on the safety relief valve function is to install a balanced bellows in a safety relief valve. The metallic bellows has a rather wide range of manufacturing tolerance which makes the design of the bellows safety relief valve very complicated. The state-of-the-art balanced bellows safety relief valve can only substantially minimize, but cannot totally eliminate the back pressure effects on its set point and relieving capacity. Set point change is a linear function of the back pressure to the set pressure ratio. Depending on the valve design, the set point correction factor can be either greater or smaller than unity. There exists an allowable back pressure and critical back pressure for each safety relief valve. When total back pressure exceeds the R a , the relieving capacity will be reduced mainly resulting from the valve lift being reduced by the back pressure and the capacity reduction factor should be applied in valve sizing. Once the R c is exceeded, the safety relief valve becomes unstable and loses its over pressure protection capability. The capacity reduction factor is a function of system overpressure, but their relationship is non-linear in nature. (orig.)

  6. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    Science.gov (United States)

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-11-01

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Development of linear flow rate control system for eccentric butter-fly valve

    International Nuclear Information System (INIS)

    Kwak, K. K.; Cho, S. W.; Park, J. S.; Cho, J. H.; Song, I. T.; Kim, J. G.; Kwon, S. J.; Kim, I. J.; Park, W. K.

    1999-12-01

    Butter-fly valves are advantageous over gate, globe, plug, and ball valves in a variety of installations, particularly in the large sizes. The purpose of this project development of linear flow rate control system for eccentric butter-fly valve (intelligent butter-fly valve system). The intelligent butter-fly valve system consist of a valve body, micro controller. The micro controller consist of torque control system, pressure censor, worm and worm gear and communication line etc. The characteristics of intelligent butter-fly valve system as follows: Linear flow rate control function. Digital remote control function. guard function. Self-checking function. (author)

  8. The SNS Resonance Control Cooling System Control Valve Upgrade Performance

    International Nuclear Information System (INIS)

    Williams, Derrick C.; Schubert, James Phillip; Tang, Johnny Y.

    2008-01-01

    The normal-conducting linac of the Spallation Neutron Source (SNS) uses 10 separate Resonance Control Cooling System (RCCS) water skids to control the resonance of 6 Drift Tube Linac (DTL) and 4 Coupled Cavity Linac (CCL) accelerating structures. The RCCS water skids use 2 control valves; one to regulate the chilled water flow and the other to bypass water to a chilled water heat exchanger. These valves have hydraulic actuators that provide position and feedback to the control system. Frequency oscillations occur using these hydraulic actuators due to their coarse movement and control of the valves. New pneumatic actuator and control positioners have been installed on the DTL3 RCCS water skid to give finer control and regulation of DTL3 cavity temperature. This paper shows a comparison of resonance control performance for the two valve configurations.

  9. Characteristics of electrostatic gas micro-pump with integrated polyimide passive valves

    International Nuclear Information System (INIS)

    Han, Jeahyeong; Yeom, Junghoon; Mensing, Glennys; Flachsbart, Bruce; Shannon, Mark A

    2012-01-01

    We report on the fabrication and characterization of electrostatic gas micro-pumps integrated with polyimide check valves. Touch-mode capacitance actuation, enabled by a fixed silicon electrode and a metal/polyimide diaphragm, creates the suction and push-out of the ambient gas; the gas flow is rectified by the check valves located at the inlet and outlet of the pump. The fabricated pumps were tested with various actuation voltages at different frequencies and duty cycles; an emphasis was placed on investigating the effect of valve flow conductance on the gas pumping characteristics. The pump with higher valve conductance could increase the operating frequency of the pump and affect the pumping characteristics from a pulsating flow to a continuous flow, leading to a higher gas flow rate. This electrostatic pump has a flow control resolution of 1 µL min −1 ; it could generate a gas flow up to 106 µL min −1 . (paper)

  10. Refuge alternatives relief valve testing and design with updated test stand.

    Science.gov (United States)

    Lutz, T J; Bissert, P T; Homce, G T; Yonkey, J A

    2018-03-01

    Underground refuge alternatives require an air source to supply breathable air to the occupants. This requires pressure relief valves to prevent unsafe pressures from building up within the refuge alternative. The U.S. Mine Safety and Health Administration (MSHA) mandates that pressure relief valves prevent pressure from exceeding 1.25 kPa (0.18 psi), or as specified by the manufacturer, above mine atmospheric pressure when a fan or compressor is used for the air supply. The U.S. National Institute for Occupational Safety and Health (NIOSH) tested a variety of pressure relief valves using an instrumented test fixture consisting of data acquisition equipment, a centrifugal blower, ductwork and various sensors to determine if the subject pressure relief valves meet the MSHA requirement. Relief pressures and flow characteristics, including opening pressure and flow rate, were measured for five different pressure relief valves under a variety of conditions. The subject pressure relief valves included two off-the-shelf modified check valves, two check valves used in MSHA-approved built-in-place refuge alternatives, and a commercially available valve that was designed for a steel refuge alternative and is currently being used in some built-in-place refuge alternatives. The test results showed relief pressures ranging from 0.20 to 1.53 kPa (0.03 to 0.22 psi) and flow rates up to 19.3 m 3 /min (683 scfm). As tested, some of the pressure relief valves did not meet the 1.25 kPa (0.18 psi) relief specification.

  11. Design and theoretical analysis of a sliding valve distribution radial piston pump

    Energy Technology Data Exchange (ETDEWEB)

    Tong, Guo; Shengdun, Zhao; Yanghuiwen, Yu [Xian Jiaotong University, Xian (China); Peng, Shang [Xian Engineering University of Armed Police Force, Xian (China)

    2016-01-15

    A Sliding valve distribution radial piston pump (SVDRPP) is presented. In this pump, a new distribution method that uses sliding valves to distribute oil for the piston chambers is developed. With this design, the disadvantages brought by the distribution shaft and the check valves (traditional distribution mechanisms), such as the poor stress state of the shaft and the energy waste for opening the check valves, are expected to be eliminated. In addition, a method of using pressure oil to accomplish the returning stroke of the piston is also proposed, which could be used to replace the usage of springs along with their shortcomings. A pump with five pistons is designed as an example to elaborate the structure and the working principle of SVDRPP. Furthermore, the flow characteristics of SVDRPP are studied, and the formulas of the displacement, the average flow rate and the instantaneous flow rate are deduced.

  12. Design and theoretical analysis of a sliding valve distribution radial piston pump

    International Nuclear Information System (INIS)

    Tong, Guo; Shengdun, Zhao; Yanghuiwen, Yu; Peng, Shang

    2016-01-01

    A Sliding valve distribution radial piston pump (SVDRPP) is presented. In this pump, a new distribution method that uses sliding valves to distribute oil for the piston chambers is developed. With this design, the disadvantages brought by the distribution shaft and the check valves (traditional distribution mechanisms), such as the poor stress state of the shaft and the energy waste for opening the check valves, are expected to be eliminated. In addition, a method of using pressure oil to accomplish the returning stroke of the piston is also proposed, which could be used to replace the usage of springs along with their shortcomings. A pump with five pistons is designed as an example to elaborate the structure and the working principle of SVDRPP. Furthermore, the flow characteristics of SVDRPP are studied, and the formulas of the displacement, the average flow rate and the instantaneous flow rate are deduced

  13. Performability assessment by model checking of Markov reward models

    NARCIS (Netherlands)

    Baier, Christel; Cloth, L.; Haverkort, Boudewijn R.H.M.; Hermanns, H.; Katoen, Joost P.

    2010-01-01

    This paper describes efficient procedures for model checking Markov reward models, that allow us to evaluate, among others, the performability of computer-communication systems. We present the logic CSRL (Continuous Stochastic Reward Logic) to specify performability measures. It provides flexibility

  14. Flow Characteristics and Sizing of Annular Seat Valves for Digital Displacement Machines

    DEFF Research Database (Denmark)

    Nørgård, Christian; Bech, Michael Møller; Andersen, Torben O.

    2018-01-01

    operating range. To achieve high machine efficiency, the valve flow losses and the required electrical power needed for valve switching should be low. The annular valve plunger geometry, of a valve prototype developed for digital displacement machines, is parametrized by three parameters: stroke length......This paper investigates the steady-state flow characteristics and power losses of annular seat valves for digital displacement machines. Annular seat valves are promising candidates for active check-valves used in digital displacement fluid power machinery which excels in efficiency in a broad...... a valve prototype. Using the simulated maps to estimate the flow power losses and a simple generic model to estimate the electric power losses, both during digital displacement operation, optimal designs of annular seat valves, with respect to valve power losses, are derived under several different...

  15. Fabrication of a phantom and its application for checking gamma camera performance

    International Nuclear Information System (INIS)

    Yesmin, S; Ahmad, G. U.; Afroz, S.; Hossain, S.; Rashid, H.

    2004-01-01

    The primary aim of the present work is to fabricate a total performance phantom, which could be used for checking the performance characteristics of gamma camera. The phantom was locally fabricated at machine shop of Bangladesh University of Engineering and Technology (BUET) and used for checking the performance characteristics of gamma camera LF-61 of Centre for Nuclear Medicine and Ultrasound, Dhaka. With 10 mCi of Tc-99m, imaging of the phantom acquired with a reasonable counts. The image was inspected physically for evaluation of the camera performances. The visual inspection of the phantom image revealed that the performance characteristics like: spatial resolution, linearity, uniformity and lesion detection capability of the gamma camera could clearly be evaluated with reasonable acceptance level. This phantom is expected to be useful for checking performance characteristics of SPECT system as well. (author)

  16. Recent NRC research activities addressing valve and pump issues

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, D.L.

    1996-12-01

    The mission of the U.S. Nuclear Regulatory Commission (NRC) is to ensure the safe design, construction, and operation of commercial nuclear power plants and other facilities in the U.S.A. One of the main roles that the Office of Nuclear Regulatory Research (RES) plays in achieving the NRC mission is to plan, recommend, and implement research programs that address safety and technical issues deemed important by the NRC. The results of the research activities provide the bases for developing NRC positions or decisions on these issues. Also, RES performs confirmatory research for developing the basis to evaluate industry responses and positions on various regulatory requirements. This presentation summarizes some recent RES supported research activities that have addressed safety and technical issues related to valves and pumps. These activities include the efforts on determining valve and motor-operator responses under dynamic loads and pressure locking events, evaluation of monitoring equipment, and methods for detecting and trending aging of check valves and pumps. The role that RES is expected to play in future years to fulfill the NRC mission is also discussed.

  17. Numerical and experimental investigation on the performance of safety valves operating with different gases

    International Nuclear Information System (INIS)

    Dossena, V.; Marinoni, F.; Bassi, F.; Franchina, N.; Savini, M.

    2013-01-01

    A detailed analysis of the effect related to the expansion of different gases throughout safety relief valves is carried out both numerically and experimentally. The considered gases are air, argon and ethylene, representative of a wide range of specific heat ratios. A first experimental campaign performed in air and argon on a safety relief valve characterized by connection 1/2″ × 1″ and orifice designation D (diameter 10 mm) according to API 526 showed significant reduction both in disc lift and in exhausted mass flow rate, at the nominal overpressure, when operating with argon. In order to gain a deeper insight into the physics involved and to evaluate the valve behavior with other gases, an extensive numerical testing has been performed by means of an accurate CFD code based on discontinuous Galerkin formulation. Numerical results are at first validated against measurements obtained in air on a 2″ J 3″ safety relief valve proving a remarkable accuracy of the computational method. Then the validated solver is applied on the same computational grid using argon and ethylene as working fluids. The three gases are considered as thermally perfect gases. A critical discussion based on the numerical results allows to clarify the fluid dynamic and physical reasons causing the observed trends both in the opening force and in the discharge coefficient. The main conclusion is that particular care must be taken when a safety valve operates with a fluid characterized by a specific heat ratio greater than the one of the gas used during type testing. -- Highlights: ► Effects of different gases on the discharge capacity and operational characteristics on safety relief valves. ► Influence of different specific heat ratio on safety relief valves discharge coefficient. ► Skilful application of Discontinuous Galerkin CFD solver to safety valves performances prediction

  18. Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves.

    Science.gov (United States)

    Johansen, Peter; Engholt, Henrik; Tang, Mariann; Nybo, Rasmus F; Rasmussen, Per D; Nielsen-Kudsk, Jens Erik

    2017-10-13

    Patients with degraded bioprosthetic heart valves (BHV) who are not candidates for valve replacement may benefit from transcatheter valve-in-valve (VIV) therapy. However, in smaller-sized surgical BHV the resultant orifice may become too narrow. To overcome this, the valve frame can be fractured by a high-pressure balloon prior to VIV. However, knowledge on fracture pressures and mechanics are prerequisites. The aim of this study was to identify the fracture pressures needed in BHV, and to describe the fracture mechanics. Commonly used BHV of small sizes were mounted on a high-pressure balloon situated in a biplane fluoroscopic system with a high-speed camera. The instant of fracture was captured along with the balloon pressure. The valves were inspected for material protrusion and later dissected for fracture zone investigation and description. The valves with a polymer frame fractured at a lower pressure (8-10 atm) than those with a metal stent (19-26 atm). None of the fractured valves had elements protruding. VIV procedures in small-sized BHV may be performed after prior fracture of the valve frame by high-pressure balloon dilatation. This study provides tentative guidelines for expected balloon sizes and pressures for valve fracturing.

  19. Comparative study of Butterfly valves

    International Nuclear Information System (INIS)

    Galmes Belmonte, F.B.

    1998-01-01

    This work tries to justify the hydrodynamic butterfly valves performance, using the EPRI tests, results carried out in laboratory and in situ. This justification will be possible if: - The valves to study are similar - Their performance is calculated using EPRI's methodology Looking for this objective, the elements of the present work are: 1. Brief EPRI butterfly valve description it wild provide the factors which are necessary to define the butterfly valves similarity. 2. EPRI tests description and range of validation against test data definition. 3. Description of the spanish butterfly analyzed valves, and comparison with the EPRI performance results, to prove that this valves are similar to the EPRI test valves. In this way, it will not be necessary to carry out particular dynamic tests on the spanish valves to describe their hydrodynamic performance. (Author)

  20. A study of waste and delivery valve design modification to the pump performance

    Science.gov (United States)

    Harith, M. N.; Bakar, R. A.; Ramasamy, D.; Kardigama, K.; Quanjin, Ma

    2018-04-01

    This paper objective is to share design revolution of waste and delivery valve that contribute to the overall pump performance. In this paper, 3 new designs of waste and delivery valve pump are presented with comprehensive internal flow analysis using computational fluid dynamics (CFD) simulation over 4 cases that have been deeply study for one of the design chosen. 4 cases involving opening and closing both valve or either one. 0.265m height size of customized waste valve with an opening limiter and spring was used to demonstrate cyclic closing and opening valve operation extended up to 0.164m gap. Based on result, this characteristics contribute to 10-20% waste water reduction and enhancement of flow rate height up to 80m. Apart from that this paper also share some of pressure (dynamic, total, static), velocity (x, y, z axis) simulation including the vector flow were under different flow cases.

  1. Flow Characteristics and Sizing of Annular Seat Valves for Digital Displacement Machines

    Directory of Open Access Journals (Sweden)

    Christian Nørgård

    2018-01-01

    Full Text Available This paper investigates the steady-state flow characteristics and power losses of annular seat valves for digital displacement machines. Annular seat valves are promising candidates for active check-valves used in digital displacement fluid power machinery which excels in efficiency in a broad operating range. To achieve high machine efficiency, the valve flow losses and the required electrical power needed for valve switching should be low. The annular valve plunger geometry, of a valve prototype developed for digital displacement machines, is parametrized by three parameters: stroke length, seat radius and seat width. The steady-state flow characteristics are analyzed using static axi-symmetric computational fluid dynamics. The pressure drops and flow forces are mapped in the valve design space for several different flow rates. The simulated results are compared against measurements using a valve prototype. Using the simulated maps to estimate the flow power losses and a simple generic model to estimate the electric power losses, both during digital displacement operation, optimal designs of annular seat valves, with respect to valve power losses, are derived under several different operating conditions.

  2. Fluid mechanics of heart valves.

    Science.gov (United States)

    Yoganathan, Ajit P; He, Zhaoming; Casey Jones, S

    2004-01-01

    Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.

  3. Performance of Low-Density Parity-Check Coded Modulation

    Science.gov (United States)

    Hamkins, Jon

    2010-01-01

    This paper reports the simulated performance of each of the nine accumulate-repeat-4-jagged-accumulate (AR4JA) low-density parity-check (LDPC) codes [3] when used in conjunction with binary phase-shift-keying (BPSK), quadrature PSK (QPSK), 8-PSK, 16-ary amplitude PSK (16- APSK), and 32-APSK.We also report the performance under various mappings of bits to modulation symbols, 16-APSK and 32-APSK ring scalings, log-likelihood ratio (LLR) approximations, and decoder variations. One of the simple and well-performing LLR approximations can be expressed in a general equation that applies to all of the modulation types.

  4. Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.

    Science.gov (United States)

    Saxon, John T; Allen, Keith B; Cohen, David J; Chhatriwalla, Adnan K

    2018-01-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient-prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient-prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions.

  5. Use of neural networks to monitor power plant components

    International Nuclear Information System (INIS)

    Ikonomopoulos, A.; Tsoukalas, L.H.

    1992-01-01

    A new methodology is presented for nondestructive evaluation (NDE) of check valve performance and degradation. Artificial neural network (ANN) technology is utilized for processing frequency domain signatures of check valves operating in a nuclear power plant (NPP). Acoustic signatures obtained from different locations on a check valve are transformed from the time domain to the frequency domain and then used as input to a pretrained neural network. The neural network has been trained with data sets corresponding to normal operation, therefore establishing a basis for check valve satisfactory performance. Results obtained from the proposed methodology demonstrate the ability of neural networks to perform accurate and quick evaluations of check valve performance

  6. Numerical Analysis of Combined Valve Hydrodynamic Characteristics for Turbine System

    International Nuclear Information System (INIS)

    Bhowmik, P. K.; Shamim, J. A.; Gairola, A.; Arif, M.; Suh, Kune Y.

    2014-01-01

    precisely by the valve manufacturer. As a matter of fact, attempts were made to obtain flow characteristic curves resorting to analytical as well as numerical methods. The flow characteristic curve relates the stem lift with mass flow rate at a specific temperature and pressure. This paper focuses on computational and numerical analysis of the combined stop and control valve. Combined Airflow Regulation Analysis (CARA) is performed to check on the hydrodynamic characteristic, which is represented by flow coefficient characteristic. CATIA V.5 and ANSYS CFX are used for three-dimensional computer-aided design and computational fluid dynamics (CFD) analysis, respectively. Flow characteristic curves are plotted by calculating theoretical and numerical mass flow rate. Hydrodynamic analysis was made of the combined stop and control valve for the turbine system using ANSYS CFX. The result of the numerical study represented by the valve flow coefficient with different normalized values of valve stem movement L/D and different pressure ratios of valve outlet and inlet agrees well with the ideal case and other similar previous experimental results. This study also provided a solid understanding with versatile options for analyzing the hydrodynamics of the combined valve considering the various internal geometry, seat, plug, and the inlet plus outlet boundary conditions to improve the efficiency, performance and reliability of the turbine system of small as well as large power conversion system using the numerical analysis with minimal cost and time

  7. Numerical Analysis of Combined Valve Hydrodynamic Characteristics for Turbine System

    Energy Technology Data Exchange (ETDEWEB)

    Bhowmik, P. K.; Shamim, J. A.; Gairola, A.; Arif, M.; Suh, Kune Y. [Seoul National Univ., Seoul (Korea, Republic of)

    2014-05-15

    precisely by the valve manufacturer. As a matter of fact, attempts were made to obtain flow characteristic curves resorting to analytical as well as numerical methods. The flow characteristic curve relates the stem lift with mass flow rate at a specific temperature and pressure. This paper focuses on computational and numerical analysis of the combined stop and control valve. Combined Airflow Regulation Analysis (CARA) is performed to check on the hydrodynamic characteristic, which is represented by flow coefficient characteristic. CATIA V.5 and ANSYS CFX are used for three-dimensional computer-aided design and computational fluid dynamics (CFD) analysis, respectively. Flow characteristic curves are plotted by calculating theoretical and numerical mass flow rate. Hydrodynamic analysis was made of the combined stop and control valve for the turbine system using ANSYS CFX. The result of the numerical study represented by the valve flow coefficient with different normalized values of valve stem movement L/D and different pressure ratios of valve outlet and inlet agrees well with the ideal case and other similar previous experimental results. This study also provided a solid understanding with versatile options for analyzing the hydrodynamics of the combined valve considering the various internal geometry, seat, plug, and the inlet plus outlet boundary conditions to improve the efficiency, performance and reliability of the turbine system of small as well as large power conversion system using the numerical analysis with minimal cost and time.

  8. [Hydrodynamics of disk artificial heart valves with different design characteristics].

    Science.gov (United States)

    Dobrova, N B; Zaretskiĭ, Iu V

    1989-01-01

    Bench tests for 38 models of artificial heart valves (AHV) with different design parameters allowed us to decide in favour of the valves with reduced eccentricity (compared to the serial AHV of the EMAHV type) according to its resistance in the constant flow. Out of the compatibility checks of the design parameters tested it was concluded that the disk did not make the complete calculated angle when rotated. The dependence of AHV resistance on the disk rotation angle showed that there is no necessity to increase that angle more than 70 degrees for the mitral valve and more than 75 degrees for the aortic AHV.

  9. Integral isolation valve systems for loss of coolant accident protection

    Science.gov (United States)

    Kanuch, David J.; DiFilipo, Paul P.

    2018-03-20

    A nuclear reactor includes a nuclear reactor core comprising fissile material disposed in a reactor pressure vessel having vessel penetrations that exclusively carry flow into the nuclear reactor and at least one vessel penetration that carries flow out of the nuclear reactor. An integral isolation valve (IIV) system includes passive IIVs each comprising a check valve built into a forged flange and not including an actuator, and one or more active IIVs each comprising an active valve built into a forged flange and including an actuator. Each vessel penetration exclusively carrying flow into the nuclear reactor is protected by a passive IIV whose forged flange is directly connected to the vessel penetration. Each vessel penetration carrying flow out of the nuclear reactor is protected by an active IIV whose forged flange is directly connected to the vessel penetration. Each active valve may be a normally closed valve.

  10. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...... and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83...

  11. Static and Dynamic Performance Simulation of Direct-Acting Force Motor Valve

    Science.gov (United States)

    Ye, Xinghai; Ding, Jianjun; Zheng, Gang; Jiang, Kunpeng; Chen, Dongdong

    2017-07-01

    This work focuses on static and dynamic characteristics of direct-acting force motor valve. First, we analyzed the structure features and operating principle of the Mitsubishi-Hitachi force motor valve (FMV) and the operating principle of its internal permanent-magnet moving-coil force motor magnetic circuit, determined the transfer function of the FMV force motor system, and established a mathematical model for the system. Secondly, we established a static performance analysis model using the AMESIM software and utilized the model in combination with experimental results to analyze the effects of electro-hydraulic servo valve structural parameters on static characteristics. Lastly, we deduced the trajectory equation of the system, established the relationship between dynamic characteristic indexes and structural parameters, and analyzed the effects of different parameter values on the dynamic characteristics of the system. This research can provide a theoretical guidance for designing and manufacturing the FMV body.

  12. Leak processing system for valve gland portion

    International Nuclear Information System (INIS)

    Nishino, Masami

    1990-01-01

    When a process fluid for a valve to be checked is at such a normal temperature as during reactor operation, leaked fluid can be detected depending on the temperature increase accompanying the leakage. However, detection is difficult if the temperature of the process fluid for the valve to be checked is low and, if leakage is detected after the reactor start-up, repair has to be applied after the shutdown of the plant. Then, gland leak is detected by detecting the pressure instead of the temperature in the pipeline system and the leak flow rate is calculated based on the pressure. As a result, leakage is detected irrespective of the temperature of the leaked fluid and, for instance, leakage can be detected even in a case where the temperature is not high as in the case of pressure proof test for the pressure vessel before start-up. It can contribute much to the improvement of the plant operation efficiency and can determine the leak flow rate at a high accuracy. (N.H.)

  13. Stainless steel valves with enhanced performance through microstructure optimization

    Science.gov (United States)

    Barani, A. A.; Boukhattam, M.; Haggeney, M.; Güler, S.

    2017-08-01

    Compressor valves are made of hardened and tempered martensitic steels. The main design criterion for the material selection is the fatigue performance of the material under bending loads. In some cases impact loads and corrosive atmospheres additionally act on the part. For the first time, the microstructure of the most commonly used stainless steel and its influence on the properties relevant for flapper valves is presented and described in this paper. It is demonstrated how the tensile properties of a martensitic stainless steel can be enhanced by tailoring the microstructure. Electron back scatter diffraction method is carried out to explain the changes in monotonic mechanical properties. Through a modified heat treatment the martensite microstructure is refined resulting in an increase of yield and ultimate tensile strength and at the same time a significant increase of elongation.

  14. Training aids: the motor operator valve trainer

    International Nuclear Information System (INIS)

    McCulloch, B.

    1987-01-01

    The spectrum of training aids used in the nuclear industry runs the gamut from the very basic (i.e., valve training aids - gate, globe, check) to the highly complex (i.e., nuclear full scope simulator). Designing and purchasing the best training aids take much time, detailed investigation, and good understanding of plant operations. The training aid that has given the New York Power Authority the best results has been the motor operator valve (MOV) trainer. Some of the items that make the MOV trainer a good choice are: (1) large number of MOVs in the plant, (2) importance of MOVs to safe plant operation, (3) detailed MOV procedures used by the plant, (4) history of MOV problems, and (5) ability to demonstrate important concepts and operation - hammer blow effect, torque and limit switch adjustment and functions, and actual sequence of operation of the limitorque valve operator

  15. Cyclonic valve test: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Andre Sampaio; Moraes, Carlos Alberto C.; Marins, Luiz Philipe M.; Soares, Fabricio; Oliveira, Dennis; Lima, Fabio Soares de; Airao, Vinicius [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Ton, Tijmen [Twister BV, Rijswijk (Netherlands)

    2012-07-01

    For many years, the petroleum industry has been developing a valve that input less shear to the flow for a given required pressure drop and this can be done using the cyclonic concept. This paper presents a comparison between the performances of a cyclonic valve (low shear) and a conventional globe valve. The aim of this work is to show the advantages of using a cyclonic low shear valve instead of the commonly used in the primary separation process by PETROBRAS. Tests were performed at PETROBRAS Experimental Center (NUEX) in Aracaju/SE varying some parameters: water cut; pressure loss (from 4 kgf/cm2 to 10 kgf/cm2); flow rates (30 m3/h and 45 m3/h). Results indicates a better performance of the cyclonic valve, if compared with a conventional one, and also that the difference of the performance, is a function of several parameters (emulsion stability, water content free, and oil properties). The cyclonic valve tested can be applied as a choke valve, as a valve between separation stages (for pressure drop), or for controlling the level of vessels. We must emphasize the importance to avoid the high shear imposed by conventional valves, because once the emulsion is created, it becomes more difficult to break it. New tests are being planned to occur in 2012, but PETROBRAS is also analyzing real cases where the applications could increase the primary process efficiency. In the same way, the future installations are also being designed considering the cyclonic valve usage. (author)

  16. AN EXPERIMENTAL INVESTIGATION OF THE EFFECTS OF VARIABLE VALVE TIMING ON THE PERFORMANCE IN SPARK IGNITION ENGINE

    Directory of Open Access Journals (Sweden)

    Ali AKBAŞ

    2001-01-01

    Full Text Available In this study, an alternative prototype has been designed and constructed for variable valve timing systems which are used in spark ignition engines. The effects of intake valve timing and lift changing on engine performance have been investigated without changing the opening duration of the valves. A four stroke, single cylinder, spark ignition engine has been used for these experiments.

  17. A modelling study into the effects of variable valve timing on the gas exchange process and performance of a 4-valve DI homogeneous charge compression ignition (HCCI) engine

    International Nuclear Information System (INIS)

    Mahrous, A-F.M.; Potrzebowski, A.; Wyszynski, M.L.; Xu, H.M.; Tsolakis, A.; Luszcz, P.

    2009-01-01

    Homogeneous charge compression ignition (HCCI) combustion mode is a relatively new combustion technology that can be achieved by using specially designed cams with reduced lift and duration. The auto-ignition in HCCI engine can be facilitated by adjusting the timing of the exhaust-valve-closing and, to some extent, the timing of the intake-valve-opening so as to capture a proportion of the hot exhaust gases in the engine cylinder during the gas exchange process. The effects of variable valve timing strategy on the gas exchange process and performance of a 4-valve direct injection HCCI engine were computationally investigated using a 1D fluid-dynamic engine cycle simulation code. A non-typical intake valve strategy was examined; whereby the intake valves were assumed to be independently actuated with the same valve-lift profile but at different timings. Using such an intake valves strategy, the obtained results showed that the operating range of the exhaust-valve-timing within which the HCCI combustion can be facilitated and maintained becomes much wider than that of the typical intake-valve-timing case. Also it was found that the engine parameters such as load and volumetric efficiency are significantly modified with the use of the non-typical intake-valve-timing. Additionally, the results demonstrated the potential of the non-typical intake-valve strategy in achieving and maintaining the HCCI combustion at much lower loads within a wide range of valve timings. Minimizing the pumping work penalty, and consequently improving the fuel economy, was shown as an advantage of using the non-typical intake-valve-timing with the timing of the early intake valve coupled with a symmetric degree of exhaust-valve-closing timing

  18. A modelling study into the effects of variable valve timing on the gas exchange process and performance of a 4-valve DI homogeneous charge compression ignition (HCCI) engine

    Energy Technology Data Exchange (ETDEWEB)

    Mahrous, A-F.M. [School of Mechanical Engineering, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom); Lecturer at the Department of Mechanical Power Engineering, Faculty of Engineering (Shebin El-Kom), Menoufiya University, Shebin El-Kom (Egypt); Potrzebowski, A.; Wyszynski, M.L.; Xu, H.M.; Tsolakis, A.; Luszcz, P. [School of Mechanical Engineering, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom)

    2009-02-15

    Homogeneous charge compression ignition (HCCI) combustion mode is a relatively new combustion technology that can be achieved by using specially designed cams with reduced lift and duration. The auto-ignition in HCCI engine can be facilitated by adjusting the timing of the exhaust-valve-closing and, to some extent, the timing of the intake-valve-opening so as to capture a proportion of the hot exhaust gases in the engine cylinder during the gas exchange process. The effects of variable valve timing strategy on the gas exchange process and performance of a 4-valve direct injection HCCI engine were computationally investigated using a 1D fluid-dynamic engine cycle simulation code. A non-typical intake valve strategy was examined; whereby the intake valves were assumed to be independently actuated with the same valve-lift profile but at different timings. Using such an intake valves strategy, the obtained results showed that the operating range of the exhaust-valve-timing within which the HCCI combustion can be facilitated and maintained becomes much wider than that of the typical intake-valve-timing case. Also it was found that the engine parameters such as load and volumetric efficiency are significantly modified with the use of the non-typical intake-valve-timing. Additionally, the results demonstrated the potential of the non-typical intake-valve strategy in achieving and maintaining the HCCI combustion at much lower loads within a wide range of valve timings. Minimizing the pumping work penalty, and consequently improving the fuel economy, was shown as an advantage of using the non-typical intake-valve-timing with the timing of the early intake valve coupled with a symmetric degree of exhaust-valve-closing timing. (author)

  19. The Performance Test for Reactor Coolant Pump (RCP) adopting Variable Restriction Orifice Type Control Valve

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S.; Bae, B. U.; Cho, Y. J. and others

    2014-05-15

    The design values of the RCPTF are 17.2 MPa, 343 .deg. C, 11.7 m{sup 3}/s, and 13 MW in the maximum pressure, temperature, flow rate, and electrical power, respectively. In the RCPTF, various types of tests can be performed including a hydraulic performance test to acquire a H-Q curve as well seal transient tests, thrust bearing transient test, cost down test, NPSHR verification test, and so on. After a commissioning startup test was successfully perfomed, mechanical structures are improved including a flow stabilizer and variable restriction orifice. Two- branch pipe (Y-branch) was installed to regulate the flow rate in the range of performance tests. In the main pipe, a flow restrictor (RO: Restriction Orifice) for limiting the maximum flow rate was installed. In the branch pipe line, a globe valve and a butterfly valves for regulating the flow rate was located on the each branch line. When the pressure loss of the valve side is smaller than that of the RO side, the flow rate of valve side was increasing and the flow disturbance was occurred in the lower pipe line. Due to flow disturbnace, it is to cause an error when measuring RCP head and flow measurement of the venturi flow meter installed in the lower main pipe line, and thus leading to a decrease in measurement accuracy as a result. To increase the efficiency of the flow control availability of the test facility, the variable restriction orifice (VRO) type flow control valve was designed and manufactured. In the RCPTF in KAERI, the performance tests and various kinds of transient tests of the RCP were successfully performed. In this study, H-Q curve of the pump using the VRO revealed a similar trend to the result from two ROs. The VRO was confirmed to effectively cover the full test range of the flow rate.

  20. Design and Performance Evaluation of an Electro-Hydraulic Camless Engine Valve Actuator for Future Vehicle Applications.

    Science.gov (United States)

    Nam, Kanghyun; Cho, Kwanghyun; Park, Sang-Shin; Choi, Seibum B

    2017-12-18

    This paper details the new design and dynamic simulation of an electro-hydraulic camless engine valve actuator (EH-CEVA) and experimental verification with lift position sensors. In general, camless engine technologies have been known for improving fuel efficiency, enhancing power output, and reducing emissions of internal combustion engines. Electro-hydraulic valve actuators are used to eliminate the camshaft of an existing internal combustion engines and used to control the valve timing and valve duration independently. This paper presents novel electro-hydraulic actuator design, dynamic simulations, and analysis based on design specifications required to satisfy the operation performances. An EH-CEVA has initially been designed and modeled by means of a powerful hydraulic simulation software, AMESim, which is useful for the dynamic simulations and analysis of hydraulic systems. Fundamental functions and performances of the EH-CEVA have been validated through comparisons with experimental results obtained in a prototype test bench.

  1. Structural valve deterioration in a starr-edwards mitral caged-disk valve prosthesis.

    Science.gov (United States)

    Aoyagi, Shigeaki; Tayama, Kei-Ichiro; Okazaki, Teiji; Shintani, Yusuke; Kono, Michitaka; Wada, Kumiko; Kosuga, Ken-Ichi; Mori, Ryusuke; Tanaka, Hiroyuki

    2013-01-01

    The durability of the Starr-Edwards (SE) mitral caged-disk valve, model 6520, is not clearly known, and structural valve deterioration in the SE disk valve is very rare. Replacement of the SE mitral disk valve was performed in 7 patients 23-40 years after implantation. Macroscopic examination of the removed disk valves showed no structural abnormalities in 3 patients, in whom the disk valves were removed at valves excised >36 years after implantation in 4 patients. Disk fracture, a longitudinal split in the disk along its circumference at the site of incorporation of the titanium ring, was detected in the valves removed 36 and 40 years after implantation, respectively, and many cracks were also observed on the outflow aspect of the disk removed 40 years after implantation. Disk fracture and localized disk wear were found in the SE mitral disk valves implanted >36 years previously. The present results suggest that SE mitral caged-disk valves implanted >20 years previously should be carefully followed up, and that those implanted >30 years previously should be electively replaced with modern prosthetic valves

  2. Use of a valve operation test and evaluation system to enhance valve reliability

    International Nuclear Information System (INIS)

    Lowry, D.A.

    1990-01-01

    Power plant owners have emphasized the need for assuring safe, reliable operation of valves. While most valves must simply open or close, the mechanisms involved can be quite complex. Motor operated valves (MOVs) must be properly adjusted to assure operability. Individual operator components determine the performance of the entire MOV. Failure in MOVs could cripple or shut down a unit. Thus, a complete valve program consisting of design reviews, operational testing, and preventive and predictive maintenance activities will enhance an owner's confidence level that his valves win operate as expected. Liberty's Valve Operation Test and Evaluation System (VOTES) accurately measures stein thrust without intruding on valve operation. Since mounting a strain gage to a valve stem is a desirable but impractical way of obtaining precise stem thrust, Liberty developed a method to obtain identical data by placing a strain gage sensor on the valve yoke. VOTES provides information which effectively eliminates costly, unscheduled downtime. This paper presents the results of infield VOTES testing. The system's proven ability to identify and characterize actuator and valve performance is demonstrated. Specific topics of discussion include the ability of VOTES to ease a utility's IE Bulletin 8543 concerns and conclusively diagnose MOV components. Data from static and differential pressure testing are presented. Technical, operational, and financial advantages resulting from VOTES technology are explored in detail

  3. Trans-apical aortic valve implantation in a patient with stentless valve degeneration.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; MacCarthy, Philip; Monaghan, Mark; Wendler, Olaf

    2011-06-01

    Trans-apical valve-in-valve trans-catheter aortic valve implantation (TAVI) has successfully been performed in selected, high-risk patients, who suffered prosthetic degeneration after aortic valve replacement using stented xenografts. We report the case of a 79-year-old male patient who underwent one of the first successful TAVIs in a failing stentless bioprosthesis. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  4. THE RESULTS OF SURGICAL TREATMENT OF TRICUSPID VALVE INFECTIVE ENDOCARDITIS USING VALVE REPAIR AND VALVE REPLACEMENT OPERATIONS

    Directory of Open Access Journals (Sweden)

    S. A. Kovalev

    2015-01-01

    Full Text Available Aim. To evaluate in-hospital and long-term results of surgical treatment of patients with infective endocarditis of the tricuspid valve, to compare the effectiveness of valve repair and valve replacement techniques, and to identify risk factors of mortality and reoperations. Materials and methods. 31 surgical patients with tricuspid valve infective endocarditis were evaluated. Patients were divided into 2 groups. In Group 1 (n = 14 repairs of the tricuspid valve were performed, in Group 2 (n = 17 patients had undergone tricuspid valve replacements. Epidemiological, clinical, microbiological and echocardiographic data were studied. Methods of comparative analysis, the Kaplan–Meier method, and Cox risk models were applied. Results. The most common complication of in-hospital stay was atrioventricular block (17.7% of cases in Group 2. In Group 1, this type of complication was not found. Hospital mortality was 7.14% in Group 1, and 0% in Group 2. Long-term results have shown the significant reduction of heart failure in general cohort and in both groups. In Group 1 the severity of heart failure in the long term was less than in Group 2. No significant differences in the severity of tricuspid regurgitation were found between the groups. In 7-year follow up no cases of death were registered in Group 1. Cumulative survival rate in Group 2 within 60 months was 67.3 ± 16.2%. No reoperations were performed in patients from Group 1. In Group 2, the freedom from reoperation within 60 months was 70.9 ± 15.3%. Combined intervention was found as predictor of postoperative mortality. Prosthetic valve endocarditis was identified as risk factor for reoperation. Conclusion. Valve repair and valve replacement techniques of surgical treatment of tricuspid valve endocarditis can provide satisfactory hospital and long-term results. Tricuspid valve repair techniques allowed reducing the incidence of postoperative atrioventricular block. In the long-term, patients

  5. Control performances of a piezoactuator direct drive valve system at high temperatures with thermal insulation

    Science.gov (United States)

    Han, Yung-Min; Han, Chulhee; Kim, Wan Ho; Seong, Ho Yong; Choi, Seung-Bok

    2016-09-01

    This technical note presents control performances of a piezoactuator direct drive valve (PDDV) operated at high temperature environment. After briefly discussing operating principle and mechanical dimensions of the proposed PDDV, an appropriate size of the PDDV is manufactured. As a first step, the temperature effect on the valve performance is experimentally investigated by measuring the spool displacement at various temperatures. Subsequently, the PDDV is thermally insulated using aerogel and installed in a large-size heat chamber in which the pneumatic-hydraulic cylinders and sensors are equipped. A proportional-integral-derivative feedback controller is then designed and implemented to control the spool displacement of the valve system. In this work, the spool displacement is chosen as a control variable since it is directly related to the flow rate of the valve system. Three different sinusoidal displacements with different frequencies of 1, 10 and 50 Hz are used as reference spool displacement and tracking controls are undertaken up to 150 °C. It is shown that the proposed PDDV with the thermal insulation can provide favorable control responses without significant tracking errors at high temperatures.

  6. Analysing sensory panel performance in a proficiency test using the PanelCheck software

    DEFF Research Database (Denmark)

    Tomic, O.; Luciano, G.; Nilsen, A.

    2010-01-01

    Check software, a workflow is proposed that guides the user through the data analysis process. This allows practitioners and non-statisticians to get an overview over panel performances in a rapid manner without the need to be familiar with details on the statistical methods. Visualisation of data analysis...... results plays an important role as this provides a time saving and efficient way of screening and investigating sensory panel performances. Most of the statistical methods used in this paper are available in the open source software PanelCheck, which may be downloaded and used for free....

  7. Infusion of the solid coal using pressure independent valves to regulate flow

    Energy Technology Data Exchange (ETDEWEB)

    Goretz, H G; Betting, K

    1979-01-01

    In order to improve infusion into the solid coal, attempts were made to effect this through several holes using a single pump; however, the regulation of the quantity of water directed into each hole by a ball-valve tap connected to the injection pump was shown to lack precision - gives the causes of this defect. Satisfactory regulation was obtained by means of pressure- independent flow valves which operate on the principle of hydrodynamic pressure balance; describes method of operation. Underground tests proved satisfactory even with large pressure variations. The problem of dirt penetration during down times was eliminated by installing a check valve. The system proves economical to run.

  8. Design and manufacture of high performance hollow engine valves by Additive Layer Manufacturing

    International Nuclear Information System (INIS)

    Cooper, D.; Thornby, J.; Blundell, N.; Henrys, R.; Williams, M.A.; Gibbons, G.

    2015-01-01

    Highlights: • High performance engine valve has been redesigned and optimised for and using ALM. • FEA was utilised to optimise and select a design for manufacture and testing. • Micro computed tomography was used in design and validation as an NDT technique. • Real world test of components was conducted to evaluate their performance. • Has demonstrated the potential for ALM in a high performance engineering context. - Abstract: Additive Layer Manufacture (ALM) of metallic components provides significant opportunities for the reduction of component weight, in order to realise improvements in vehicle fuel efficiency or performance. This paper examines the potential benefits of ALM with regard to reducing the weight of Internal Combustion Engine inlet or exhaust valves. A case study component is presented, for which an improved ALM design has been created, manufactured and evaluated. Micro-Computed Tomography (μ-CT) scanning was utilised to reverse engineer an original component, and to assess the ALM component’s internal geometry and material integrity. The case study valve was re-designed using Finite Element Analysis (FEA) to select a light weighted design which provides a conservative 9.4 g, (20%) weight saving on the Original Equipment Manufacturer (OEM) component. An engine test of over 175,000 cycles at between 2000 and 9500 rpm was conducted, after which μ-CT scanning confirmed no evidence of internal cracking, failure or significant deformation

  9. Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis.

    Science.gov (United States)

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel; Brito, João; Sondergaard, Lars; Neves, José P; Abecasis, João; M Gabriel, Henrique

    2017-03-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for surgery due to advanced age and comorbidities. The patient underwent a first TAVI, with implantation of a Medtronic CoreValve ® , which became dislodged and migrated to the ascending aorta. Due to the previous balloon valvuloplasty, the patient's AS became moderate, and her symptoms improved. After several months, she required another intervention, performed with a St. Jude Portico ® repositionable self-expanding transcatheter aortic valve. There was a good clinical response that was maintained at one-year follow-up. The use of a self-expanding transcatheter bioprosthesis with repositioning features is a solution in cases of valve dislocation to avoid suboptimal positioning of a second implant, especially when the two valves have to be positioned overlapping or partially overlapping each other. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. DEVELOPMENT OF NEW VALVE STEELS FOR APPLICATION IN HIGH PERFORMANCE ENGINES

    Directory of Open Access Journals (Sweden)

    Alexandre Bellegard Farina

    2013-12-01

    Full Text Available UNS N07751 and UNS N07080 alloys are commonly applied for automotive valves production for high performance internal combustion engines. These alloys present high hot resistance to mechanical strength, oxidation, corrosion, creep and microstructural stability. However, these alloys presents low wear resistance and high cost due to the high nickel contents. In this work it is presented the development of two new Ni-based alloys for application in high performance automotive valve as an alternative to the alloys UNS N07751 and UNS N07080. The new developed alloys are based on a high nickel-chromium austenitic matrix with dispersion of γ’ and γ’’ phases and containing different NbC contents. Due to the nickel content reduction in the developed alloys in comparison with these actually used alloys, the new alloys present an economical advantage for substitution of UNS N07751 and UNS N0780 alloys.

  11. An analysis of the ArcCHECK-MR diode array's performance for ViewRay quality assurance.

    Science.gov (United States)

    Ellefson, Steven T; Culberson, Wesley S; Bednarz, Bryan P; DeWerd, Larry A; Bayouth, John E

    2017-07-01

    The ArcCHECK-MR diode array utilizes a correction system with a virtual inclinometer to correct the angular response dependencies of the diodes. However, this correction system cannot be applied to measurements on the ViewRay MR-IGRT system due to the virtual inclinometer's incompatibility with the ViewRay's multiple simultaneous beams. Additionally, the ArcCHECK's current correction factors were determined without magnetic field effects taken into account. In the course of performing ViewRay IMRT quality assurance with the ArcCHECK, measurements were observed to be consistently higher than the ViewRay TPS predictions. The goals of this study were to quantify the observed discrepancies and test whether applying the current factors improves the ArcCHECK's accuracy for measurements on the ViewRay. Gamma and frequency analysis were performed on 19 ViewRay patient plans. Ion chamber measurements were performed at a subset of diode locations using a PMMA phantom with the same dimensions as the ArcCHECK. A new method for applying directionally dependent factors utilizing beam information from the ViewRay TPS was developed in order to analyze the current ArcCHECK correction factors. To test the current factors, nine ViewRay plans were altered to be delivered with only a single simultaneous beam and were measured with the ArcCHECK. The current correction factors were applied using both the new and current methods. The new method was also used to apply corrections to the original 19 ViewRay plans. It was found the ArcCHECK systematically reports doses higher than those actually delivered by the ViewRay. Application of the current correction factors by either method did not consistently improve measurement accuracy. As dose deposition and diode response have both been shown to change under the influence of a magnetic field, it can be concluded the current ArcCHECK correction factors are invalid and/or inadequate to correct measurements on the ViewRay system. © 2017 The

  12. Simulant Development for Hanford Tank Farms Double Valve Isolation (DVI) Valves Testing

    Energy Technology Data Exchange (ETDEWEB)

    Wells, Beric E.

    2012-12-21

    Leakage testing of a representative sample of the safety-significant isolation valves for Double Valve Isolation (DVI) in an environment that simulates the abrasive characteristics of the Hanford Tank Farms Waste Transfer System during waste feed delivery to the Waste Treatment and Immobilization Plant (WTP) is to be conducted. The testing will consist of periodic leak performed on the DVI valves after prescribed numbers of valve cycles (open and close) in a simulated environment representative of the abrasive properties of the waste and the Waste Transfer System. The valve operations include exposure to cycling conditions that include gravity drain and flush operation following slurry transfer. The simulant test will establish the performance characteristics and verify compliance with the Documented Safety Analysis. Proper simulant development is essential to ensure that the critical process streams characteristics are represented, National Research Council report “Advice on the Department of Energy's Cleanup Technology Roadmap: Gaps and Bridges”

  13. Advancements in valve technology and industry lessons lead to improved plant reliability and cost savings

    International Nuclear Information System (INIS)

    Sharma, V.; Kalsi, M.S.

    2005-01-01

    Plant reliability and safety hinges on the proper functioning of several valves. Recent advancements in valve technology have resulted in new analytical and test methods for evaluating and improving valve and actuator reliability. This is especially significant in critical service applications in which the economic impact of a valve failure on production, outage schedules and consequential damages far surpasses the initial equipment purchase price. This paper presents an overview of recent advances in valve technology driven by reliability concerns and cost savings objectives without comprising safety in the Nuclear Power Industry. This overview is based on over 27 years of experience in supporting US and International nuclear power utilities, and contributing to EPRI, and NSSS Owners' Groups in developing generic models/methodologies to address industry wide issues; performing design basis reviews; and implementing plant-wide valve reliability improvement programs. Various analytical prediction software and hardware solutions and training seminars are now available to implement valve programs covering power plants' lifecycle from the construction phase through life extension and power up rate. These tools and methodologies can enhance valve-engineering activities including the selection, sizing, proper application, condition monitoring, failure analysis, and condition based maintenance optimization with a focus on potential bad actors. This paper offers two such examples, the Kalsi Valve and Actuator Program (KVAP) and Check Valve Analysis and Prioritization (CVAP) [1-3, 8, 9, 11-13]. The advanced, validated torque prediction models incorporated into KVAP software for AOVs and MOVs have improved reliability of margin predictions and enabled cost savings through elimination of unwarranted equipment modifications. CVAP models provides a basis to prioritize the population of valves recommended for preventive maintenance, inspection and/or modification, allowing

  14. The Canadian experience in performing accuracy checks on administered doses of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Santry, Dallas

    1998-01-01

    A calibration service was introduced in 1986 to assist the Canadian nuclear medicine community in determining more accurately the amount of radioactive material administered to patients for either diagnostic or therapeutic purposes. This aspect of a quality assurance program in nuclear medicine provides an accuracy check on instruments and the technologists using them. The calibration report issued constitutes direct traceability of a facility to a national standards laboratory. Nuclides most frequently calibrated are 99m Tc and 131 I. Others include 67 Ga, 111 In, 123 I, 125 I and 201 Tl. All samples received are analysed for radionuclidic impurities by high-resolution X-ray and gamma-ray spectrometry. Ten years of testing has shown that, except for a few conscientious departments, accuracy checks on radionuclide (dose) calibrators are not a high priority. There are 285 nuclear medicine facilities in Canada and, since there is no legal requirement that the calibrators be checked for accuracy, only 29 have had their instruments checked using this service. Of these, 14 perform annual accuracy checks with NRCC. In this paper, the results of the intercomparisons are described, and quality control problems associated with the use of radionuclide calibrators in nuclear medicine are discussed

  15. Butterfly valve of all rubber lining type

    International Nuclear Information System (INIS)

    Shimada, Shosaku; Nakatsuma, Sumiya; Sasaki, Iwao; Aoki, Naoshi.

    1982-01-01

    The valves used for the circulating water pipes for condensers in nuclear and thermal power stations have become large with the increase of power output, and their specifications have become strict. The materials for the valves change from cast iron to steel plate construction. To cope with sea water corrosion, rubber lining has been applied to the internal surfaces of valve boxes, and the build-up welding of stainless steel has been made on the edges of valves. However, recently it is desired to develop butterfly valves, of which the whole valve disks are lined with hard rubber. For the purpose of confirming the performance of large bore valves, a 2600 mm bore butterfly valve of all rubber lining type was used, and the opening and closing test of 1100 times was carried out by applying thermal cycle and pressure difference and using artifical sea water. Also the bending test of hard rubber lining was performed with test pieces. Thus, it was confirmed that the butterfly valves of all rubber lining type have the performance exceeding that of the valves with build-up welding. The course of development of the valves of all rubber lining type, the construction and the items of confirmation by tests of these valves, and the tests of the valve and the hard rubber lining described above are reported. (Kako, I.)

  16. Valve performance concept move from preventive to condition-oriented maintenance

    International Nuclear Information System (INIS)

    Zanner, G.; Kradepohl, P.

    1996-01-01

    As a turnkey supplier of nuclear and fossil power plants, Siemens must pay attention in concentrating, maintaining, and developing the expertise in many areas such as system design, components, materials, quality assurance, and qualification testing within centralized organizations. In the company segment VALVES, Siemens/KWU is staffed with experienced professionals who have serviced the power plant industry for about 25 years. The valve engineers deal with all kinds of valve and actuator-related activities like design ratings, development, qualifications, and ongoing improvements. In this regard, the engineers are involved in nearly all actual problems and suggested solutions through continuing dialogues with utilities, authorities, and vendors of valves and actuators

  17. Valve performance concept move from preventive to condition-oriented maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Zanner, G.; Kradepohl, P.

    1996-12-01

    As a turnkey supplier of nuclear and fossil power plants, Siemens must pay attention in concentrating, maintaining, and developing the expertise in many areas such as system design, components, materials, quality assurance, and qualification testing within centralized organizations. In the company segment VALVES, Siemens/KWU is staffed with experienced professionals who have serviced the power plant industry for about 25 years. The valve engineers deal with all kinds of valve and actuator-related activities like design ratings, development, qualifications, and ongoing improvements. In this regard, the engineers are involved in nearly all actual problems and suggested solutions through continuing dialogues with utilities, authorities, and vendors of valves and actuators.

  18. Characteristic analysis of servo valve

    International Nuclear Information System (INIS)

    Ko, J. H.; Ryu, D. R.; Lee, J. H.; Kim, Y. S.; Na, J. C.; Kim, D. S.

    2008-01-01

    Electro-pneumatic servo valve is an electro-mechanical device which converts electric signals into a proper pneumatic flow rate or pressure. In order to improve the overall performance of pneumatic servo systems, electro-pneumatic servo valves are required, which have fast dynamic characteristics, no air leakage at a null point, and can be fabricated at a low-cost. The first objective of this research is to design and to fabricate a new electro-pneumatic servo valve which satisfies the above-mentioned requirements. In order to design the mechanism of the servo valve optimally, the flow inside the valve depending upon the position of spool was analyzed variously, and on the basis of such analysis results, the valve mechanism, which was formed by combination of the spool and the sleeve, was designed and manufactured. And a tester for conducting an overall performance test was designed and manufactured, and as a result of conducting the flow rate test, the pressure test and the frequency test on the developed pneumatic servo valve

  19. Risk evaluation for motor operated valves in an Inservice Testing Program at a PWR nuclear power plant in Taiwan

    International Nuclear Information System (INIS)

    Li, Y.C.; Chen, K.T.; Su, Y.L.; Ting, K.; Chien, F.T.; Li, G.D.; Huang, S.H.

    2012-01-01

    Safety related valves such as Motor Operated Valves (MOV), Air Operated Valves (AOV) or Check Valves (CV) play an important role in nuclear power plant. Functioning of these valves mainly aim at emergency reactivity control, post-accident residue heat removal, post-accident radioactivity removal and containment isolation when a design basis accident occurred. In order to maintain these valves under operable conditions, an Inservice Testing Program (IST) is defined for routine testing tasks based on the ASME Boiler and Pressure Vessel Code section XI code requirements. Risk based Inservice Testing Programs have been studied and developed extensively in the nuclear energy industry since the 1990s. Risk Based evaluations of IST can bring positive advantages to the licensee such as identifying the vulnerability of the system, reducing unnecessary testing burden, concentrating testing resources on the critical pass oriented valves and saving plant’s personnel dose exposure. This risk evaluation is incorporated with quantitative and qualitative analyses to the Motor Operated Valves under current Inservice Testing Program for PWR nuclear power plant in Taiwan. With the outcome of the risk classifications for the safety related MOVs through numerical or deterministic analyses, a risk based testing frequency relief is suggested to demonstrate the benefits received from the risk based Inservice Testing Program. The goal made of this study, it could be as a reference and cornerstone for the licensee to perform overall scope Risk-Informed Inservice Testing Program (RI-IST) evaluation by referring relevant methodologies established in this study.

  20. Volume-constrained optimization of magnetorheological and electrorheological valves and dampers

    Science.gov (United States)

    Rosenfeld, Nicholas C.; Wereley, Norman M.

    2004-12-01

    This paper presents a case study of magnetorheological (MR) and electrorheological (ER) valve design within a constrained cylindrical volume. The primary purpose of this study is to establish general design guidelines for volume-constrained MR valves. Additionally, this study compares the performance of volume-constrained MR valves against similarly constrained ER valves. Starting from basic design guidelines for an MR valve, a method for constructing candidate volume-constrained valve geometries is presented. A magnetic FEM program is then used to evaluate the magnetic properties of the candidate valves. An optimized MR valve is chosen by evaluating non-dimensional parameters describing the candidate valves' damping performance. A derivation of the non-dimensional damping coefficient for valves with both active and passive volumes is presented to allow comparison of valves with differing proportions of active and passive volumes. The performance of the optimized MR valve is then compared to that of a geometrically similar ER valve using both analytical and numerical techniques. An analytical equation relating the damping performances of geometrically similar MR and ER valves in as a function of fluid yield stresses and relative active fluid volume, and numerical calculations are provided to calculate each valve's damping performance and to validate the analytical calculations.

  1. Development of an effective valve packing program

    Energy Technology Data Exchange (ETDEWEB)

    Hart, K.A.

    1996-12-01

    Current data now shows that graphite valve packing installed within the guidance of a controlled program produces not only reliable stem sealing but predictable running loads. By utilizing recent technological developments in valve performance monitoring for both MOV`s and AOV`s, valve packing performance can be enhanced while reducing maintenance costs. Once known, values are established for acceptable valve packing loads, the measurement of actual valve running loads via the current MOV/AOV diagnostic techniques can provide indication of future valve stem sealing problems, improper valve packing installation or identify the opportunity for valve packing program improvements. At times the full benefit of these advances in material and predictive technology remain under utilized due to simple past misconceptions associated with valve packing. This paper will explore the basis for these misconceptions, provide general insight into the current understanding of valve packing and demonstrate how with this new understanding and current valve diagnostic equipment the key aspects required to develop an effective, quality valve packing program fit together. The cost and operational benefits provided by this approach can be significant impact by the: elimination of periodic valve repacking, reduction of maintenance costs, benefits of leak-free valve operation, justification for reduced Post Maintenance Test Requirements, reduced radiation exposure, improved plant appearance.

  2. Bentall Operation with Valved Homograft Conduit

    Science.gov (United States)

    Choudhary, Shiv K.; Talwar, Sachin; Kumar, A. Sampath

    2000-01-01

    Lesions of the ascending aorta associated with aortic valve disease are usually treated by implanting a prosthetic valved conduit (Bentall procedure). In this report, we present our experience in which a valved homograft conduit was used for the procedure. Six patients underwent a Bentall procedure with the use of a cryopreserved valved homograft conduit. Two of the patients had annuloaortic ectasia, 2 had Marfan syndrome, and 1 had an atherosclerotic aneurysm of the aorta. One patient had severe aortic stenosis due to a bicuspid aortic valve, along with an aneurysm and localized dissection of the ascending aorta. In all of the patients, the aortic annulus was substantially dilated, with accompanying moderate-to-severe aortic regurgitation. A standard procedure was performed with moderate hypothermia, cardiopulmonary bypass, and aortic and bicaval cannulation. The ascending aorta and the aortic valve were replaced with a cryopreserved valved homograft conduit (aortic in 5 patients and pulmonary in 1). The native coronary ostia were anastomosed directly to the homograft. Echocardiography, which was performed intraoperatively, before discharge from the hospital, and at follow-up visits (1 to 36 months), revealed good valve function without dilatation of the homograft conduits. There was 1 late death due to Aspergillus fumigatus endocarditis, 6 months postoperatively. In 1 patient, magnetic resonance imaging performed at 24 months revealed normal caliber of the homograft conduit. We conclude that the Bentall procedure can be performed, safely and with excellent results, using cryopreserved homograft conduits. PMID:11198310

  3. An audit of level two and level three checks of anaesthesia delivery systems performed at three hospitals in South Australia.

    Science.gov (United States)

    Sweeney, N; Owen, H; Fronsko, R; Hurlow, E

    2012-11-01

    Anaesthetists may subject patients to unnecessary risk by not checking anaesthetic equipment thoroughly before use. Numerous adverse events have been associated with failure to check equipment. The Australian and New Zealand College of Anaesthetists and anaesthetic delivery system manufactures have made recommendations on how anaesthetic equipment should be maintained and checked before use and for the training required for staff who use such equipment. These recommendations are made to minimise the risk to patients undergoing anaesthesia. This prospective audit investigated the adherence of anaesthetic practitioners to a selection of those recommendations. Covert observations of anaesthetic practitioners were made while they were checking their designated anaesthetic machine, either at the beginning of a day's list or between cases. Structured interviews with staff who check the anaesthetic machine were carried out to determine the training they had received. The results indicated poor compliance with recommendations: significantly, the backup oxygen cylinders' pressure/contents were not checked in 45% of observations; the emergency ventilation device was not checked in 67% of observations; the breathing circuit was not tested between patients in 79% of observations; no documentation of the checks performed was done in any cases; and no assessment or accreditation of the staff who performed these checks was performed. It was concluded that the poor compliance was a system failing and that patient safety might be increased with training and accrediting staff responsible for checking equipment, documenting the checks performed, and the formulation and use of a checklist.

  4. Performing Isoelectric Focusing and Simultaneous Fractionation of Proteins on A Rotary Valve Followed by Sodium Dodecyl – Polyacrylamide Gel Electrophoresis

    Science.gov (United States)

    Wang, Wei; Lu, Joann J.; Gu, Congying; Zhou, Lei; Liu, Shaorong

    2013-01-01

    In this technical note, we design and fabricate a novel rotary valve and demonstrate its feasibility for performing isoelectric focusing and simultaneous fractionation of proteins, followed by sodium dodecyl – polyacrylamide gel electrophoresis. The valve has two positions. In one position, the valve routes a series of capillary loops together into a single capillary tube where capillary isoelectric focusing (CIEF) is performed. By switching the valve to another position, the CIEF-resolved proteins in all capillary loops are isolated simultaneously, and samples in the loops are removed and collected in vials. After the collected samples are briefly processed, they are separated via sodium dodecyl – polyacrylamide gel electrophoresis (SDS-PAGE, the 2nd-D separation) on either a capillary gel electrophoresis instrument or a slab-gel system. The detailed valve configuration is illustrated, and the experimental conditions and operation protocols are discussed. PMID:23819755

  5. Environmental qualification testing of TFE valve components

    International Nuclear Information System (INIS)

    Eyvindson, A.; Krasinski, W.; McCutcheon, R.

    1997-01-01

    Valves containing tetrafluoroethylene (TFE) components are being used in many CANDU Nuclear Generating Stations. However, some concerns remain about the performance of TFE after exposure to high levels of radiation. Stations must therefore ensure that such valves perform reliably after being exposed to postulated accident radiation dose levels. The current Ontario Hydro Environmental Qualification [EQ] program specifies much higher postulated radiation exposure than the original design, to account for conditions following a LOCA. Initial assessments indicated that Teflon components would require replacement. Proof of acceptable performance can remove the need for large scale replacement, avoiding a significant cost penalty and preserving benefits due to the superior performance of TFE-based seals. A test program was undertaken at Chalk River Laboratories (CRL) to investigate the performance of three valves after irradiation to 10 Mrad. Such valves are currently used at the Bruce B Nuclear Generating Station. Each contains TFE packing rings; one also has TFE seats. Two of the valves are used in the ECIS recovery system, while the third is used for instrumentation loop isolation or as drain valves. All are exposed to little or no radiation during normal use. Based on the results of the tests, all the valves tested will still meet functional and performance requirements after the TFE components have been exposed to 10 Mrad of irradiation. (author)

  6. WE-D-BRA-07: Analysis of ArcCHECK Diode Array Performance for ViewRay Quality Assurance

    International Nuclear Information System (INIS)

    Ellefson, S; Culberson, W; Bednarz, B; DeWerd, L; Bayouth, J

    2015-01-01

    Purpose: Discrepancies in absolute dose values have been detected between the ViewRay treatment planning system and ArcCHECK readings when performing delivery quality assurance on the ViewRay system with the ArcCHECK-MR diode array (SunNuclear Corporation). In this work, we investigate whether these discrepancies are due to errors in the ViewRay planning and/or delivery system or due to errors in the ArcCHECK’s readings. Methods: Gamma analysis was performed on 19 ViewRay patient plans using the ArcCHECK. Frequency analysis on the dose differences was performed. To investigate whether discrepancies were due to measurement or delivery error, 10 diodes in low-gradient dose regions were chosen to compare with ion chamber measurements in a PMMA phantom with the same size and shape as the ArcCHECK, provided by SunNuclear. The diodes chosen all had significant discrepancies in absolute dose values compared to the ViewRay TPS. Absolute doses to PMMA were compared between the ViewRay TPS calculations, ArcCHECK measurements, and measurements in the PMMA phantom. Results: Three of the 19 patient plans had 3%/3mm gamma passing rates less than 95%, and ten of the 19 plans had 2%/2mm passing rates less than 95%. Frequency analysis implied a non-random error process. Out of the 10 diode locations measured, ion chamber measurements were all within 2.2% error relative to the TPS and had a mean error of 1.2%. ArcCHECK measurements ranged from 4.5% to over 15% error relative to the TPS and had a mean error of 8.0%. Conclusion: The ArcCHECK performs well for quality assurance on the ViewRay under most circumstances. However, under certain conditions the absolute dose readings are significantly higher compared to the planned doses. As the ion chamber measurements consistently agree with the TPS, it can be concluded that the discrepancies are due to ArcCHECK measurement error and not TPS or delivery system error. This work was funded by the Bhudatt Paliwal Professorship and the

  7. Cavitation problems in sodium valves

    International Nuclear Information System (INIS)

    Elie, X.

    1976-01-01

    Cavitation poses few problems for sodium valves, in spite of the fact that the loops are not pressurized. This is no doubt due to the low flow velocities in the pipes. For auxiliary loop valves we are attempting to standardize performances with respect to cavitation. For economic reasons cavitation thresholds are approached with large diameter valves. (author)

  8. Investigation on the Effects of Internal EGR by Variable Exhaust Valve Actuation with Post Injection on Auto-ignited Combustion and Emission Performance

    Directory of Open Access Journals (Sweden)

    Insu Cho

    2018-04-01

    Full Text Available Variable valve mechanisms are usually applied to a gasoline combustion engine to improve its power performance by controlling the amount of intake air according to the operating load. These mechanisms offer one possibility of resolving the conflict of objectives between a further reduction of raw emissions and an improvement in fuel efficiency. In recent years, variable valve control systems have become extremely important in the diesel combustion engine. Importantly, it has been shown that there are several potential benefits of applying variable valve timing (VVT to a compression ignition engine. Valve train variability could offer one option to achieve the reduction goals of engine-out emissions and fuel consumption. The aim of this study was to investigate the effects on part load combustion and emission performance of internal exhaust gas recirculation (EGR by variable exhaust valve lift actuation using a cam-in-cam system, which is an electronically variable valve device with a variable inside cam retarded to about 30 degrees. Numerical simulation based on GT-POWER has been performed to predict the NOx reduction strategy at the part load operating point of 1200 rpm in a four-valve diesel engine. A GT-POWER model of a common-rail direct injection engine with internal EGR was built and verified with experimental data. As a result, large potential for reducing NOx emissions through the use of exhaust valve control has been identified. Namely, it is possible to utilize heat efficiently as recompression of retarded post injection with downscaled specification of the exhaust valve rather than the intake valve, even if the CIC V1 condition with a reduction of the exhaust valve has a higher internal EGR rate of about 2% compared to that of the CIC V2 condition.

  9. Three-year hemodynamic performance, left ventricular mass regression, and prosthetic-patient mismatch after rapid deployment aortic valve replacement in 287 patients.

    Science.gov (United States)

    Haverich, Axel; Wahlers, Thorsten C; Borger, Michael A; Shrestha, Malakh; Kocher, Alfred A; Walther, Thomas; Roth, Matthias; Misfeld, Martin; Mohr, Friedrich W; Kempfert, Joerg; Dohmen, Pascal M; Schmitz, Christoph; Rahmanian, Parwis; Wiedemann, Dominik; Duhay, Francis G; Laufer, Günther

    2014-12-01

    Superior aortic valve hemodynamic performance can accelerate left ventricular mass regression and enhance survival and functional status after surgical aortic valve replacement. This can be achieved by rapid deployment aortic valve replacement using a subannular balloon-expandable stent frame, which functionally widens and reshapes the left ventricular outflow tract, to ensure a larger effective orifice area compared with conventional surgical valves. We report the intermediate-term follow-up data from a large series of patients enrolled in the Surgical Treatment of Aortic Stenosis With a Next Generation Surgical Aortic Valve (TRITON) trial. In a prospective, multicenter (6 European hospitals), single-arm study, 287 patients with aortic stenosis underwent rapid deployment aortic valve replacement using a stented trileaflet bovine pericardial bioprosthesis. Core laboratory echocardiography was performed at baseline, discharge, and 3 months, 1 year, and 3 years after rapid deployment aortic valve replacement. The mean patient age was 75.7 ± 6.7 years (range, 45-93; 49.1% women). The mean aortic valve gradient significantly decreased from discharge to 3 years of follow-up. The mean effective orifice area remained stable from discharge to 3 years. At 1 year, the left ventricular mass index had decreased by 14% (P replacement using a subannular balloon-expandable stent frame demonstrated excellent hemodynamic performance and significant left ventricular mass regression. With continued follow-up, future studies will establish whether these favorable structural changes correlate with improvement in long-term survival and functional status. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  10. Investigations on pneumatically forced-actuated compressor valves

    Science.gov (United States)

    Stöckel, Christian; Thomas, Christiane; Nickl, Jörg; Hesse, Ullrich

    2017-08-01

    In the present paper the performance of a novel designed valve for reciprocating piston machines is investigated, which makes existing compressors utilizable for operating as expander. Three design parameters were identified as critical for the valves performance particularly in forced actuated mode. Within a numerical simulation a study on the crucial geometrical parameters, the influence could be observed. Afterwards the experimental setup for the integral test of the valve design is presented and also additional tests for single valve components.

  11. A jazz-based approach for optimal setting of pressure reducing valves in water distribution networks

    Science.gov (United States)

    De Paola, Francesco; Galdiero, Enzo; Giugni, Maurizio

    2016-05-01

    This study presents a model for valve setting in water distribution networks (WDNs), with the aim of reducing the level of leakage. The approach is based on the harmony search (HS) optimization algorithm. The HS mimics a jazz improvisation process able to find the best solutions, in this case corresponding to valve settings in a WDN. The model also interfaces with the improved version of a popular hydraulic simulator, EPANET 2.0, to check the hydraulic constraints and to evaluate the performances of the solutions. Penalties are introduced in the objective function in case of violation of the hydraulic constraints. The model is applied to two case studies, and the obtained results in terms of pressure reductions are comparable with those of competitive metaheuristic algorithms (e.g. genetic algorithms). The results demonstrate the suitability of the HS algorithm for water network management and optimization.

  12. WE-E-BRB-10: DosCheck - an Electronic Chart Checking Tool for Dosimetrists.

    Science.gov (United States)

    Yang, D; Wu, Y; Yaddanapudi, S; Moore, K; Pierbuxg, B; Brame, S; Mutic, S

    2012-06-01

    In addition to treatment planning, dosimetrists have to prepare documentation and manually enter data in treatment management system (TMS) which did not transfer or setup automatically. The required documents and data are dependent on the disease site, treatment machine and clinical workflow. Errors and inconsistencies can cause redundant work, treatment delays and potentially treatment errors. To address these issues, an electronic checking software tool, DosCheck was clinically implemented to check the existence of necessary documentations and the integrity of manually-entered data. The purpose of this software is to reduce the frequency of human errors and to improve efficiency. DosCheck reads data and documents from 1) TMS, 2) Pinnacle TPS, and 3) DICOM plan files stored in a DICOM-RT PACS. It processes documents in Word and PDF format, treatment plan data in Pinnacle native format and DICOM format, and Mosaiq data in database records. The software cross-checks data accuracy and consistency by following rules that are pre-defined according to the clinical requirements and treatment sties. It interacts with dosimetrists and presents instantaneous results via graphical user interface. DosCheck has been implemented in C#. It performs a full check for a patient with 20 seconds. It has been clinically commissioned and is used daily by all dosimetrists at our institution. Retrospective analysis shows that DosCheck identifies 30% to 40% of previously reported dosimetrist human errors. Additional ∼30% errors are checked by other tools that could be integrated DosCheck in the near future. As an electronic data checking tool, DosCheck can obtain and process data and documents from multiple clinical computer systems in the radiation oncology department, and perform checks according to clinical rules. It is able to improve the accuracy and efficiency of clinical data and document process, and therefore to reduce any potential inconsistencies and errors. © 2012 American

  13. Recent performance experience with US light water reactor self-actuating safety and relief valves

    Energy Technology Data Exchange (ETDEWEB)

    Hammer, C.G.

    1996-12-01

    Over the past several years, there have been a number of operating reactor events involving performance of primary and secondary safety and relief valves in U.S. Light Water Reactors. There are several different types of safety and relief valves installed for overpressure protection of various safety systems throughout a typical nuclear power plant. The following discussion is limited to those valves in the reactor coolant systems (RCS) and main steam systems of pressurized water reactors (PWR) and in the RCS of boiling water reactors (BWR), all of which are self-actuating having a setpoint controlled by a spring-loaded disk acting against system fluid pressure. The following discussion relates some of the significant recent experience involving operating reactor events or various testing data. Some of the more unusual and interesting operating events or test data involving some of these designs are included, in addition to some involving a number of similar events and those which have generic applicability.

  14. An application of the valve-leak monitoring system to the valves for the improved Korean standard nuclear power plant (KSNP+)

    International Nuclear Information System (INIS)

    Byeong-yeol AHN; Dae-sik CHOI; Sang-kook CHUNG

    2006-01-01

    The loss of steam due to valve leakage leads to the inefficiency of power generation at the nuclear power plants. Under the normal conditions of plant operation, it is difficult to detect valve leaks early enough to prevent consequential damages and losses. The capability of timely detection allows the plant adequate time to prepare repair plans, which would ultimately result in efficient power production. Therefore, timing of detection is one of the most important factors in dealing with valve leakage problems. The VLMS has been developed to meet such an industrial demand. It provides early detection of valve leakage by real-time monitoring through the acoustic sensors installed on the inlet and the outlet of the valve. The KSNP+ utilizes the VLMS to enhance the performance and maintenance of major valves at plants. The VLMS will enable the plant to detect the leakage of valve at an early stage. It can reduce the steam losses and save related valve maintenance cost by performing fast diagnosis of valve leakage. (authors)

  15. Performance research on modified KCS (Kalina cycle system) 11 without throttle valve

    International Nuclear Information System (INIS)

    He, Jiacheng; Liu, Chao; Xu, Xiaoxiao; Li, Yourong; Wu, Shuangying; Xu, Jinliang

    2014-01-01

    Two modified systems based on a KCS (Kalina cycle system) 11 with a two-phase expander to substitute a throttle valve are proposed. The two-phase expander is located between the regenerator and the absorber in the B-modified cycle and between the separator and the regenerator in the C-modified cycle. A thermodynamic performance analysis of both the original KCS 11 and the modified systems is carried out. The optimization of two key parameters (the concentration of working fluid and the temperature of cooling water) is also conducted. It is shown that the two modified cycles have different performance under the investigated conditions. Results also indicate that the C-modified cycle can obtain better thermodynamic effect than the B-modified cycle. The temperature of cooling water plays an important role in improving the system performance. When the cooling water temperature drops from 303 K to 278 K, the C-modified cycle thermal efficiency can be improved by 27%. - Highlights: • Throttling valve is replaced by a two-phase expander to recover the expansion work. • Thermodynamic performance of two modified cycle systems is very different. • The maximum increase of work output by C-modified cycle compared with KCS (Kalina cycle system) 11 is 9.4%. • The ranges of ammonia content of B-modified cycle are rather larger

  16. Valve-sparing aortic root replacement†.

    Science.gov (United States)

    Koolbergen, David R; Manshanden, Johan S J; Bouma, Berto J; Blom, Nico A; Mulder, Barbara J M; de Mol, Bas A J M; Hazekamp, Mark G

    2015-02-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed. Median age was 40.3 (range: 13.4-68.6) years and 67 (69.1%) were male. Seven (7.2%) patients were younger than 18 years, the youngest being 13.4 years. Fifty-four (55.7%) had Marfan syndrome, 2 (2.1%) other fibrous tissue diseases, 15 (15.5%) bicuspid aortic valve and 3 (3.1%) had earlier Fallot repair. The reimplantation technique was used in all, with a straight vascular prosthesis in 11 (26-34 mm) and the Valsalva prosthesis in 86 (26-32 mm). Concomitant aortic valve repair was performed in 43 (44.3%), mitral valve repair in 10 (10.3%), tricuspid valve repair in 5 (5.2%) and aortic arch replacement in 3 (3.1%). Mean follow-up was 4.2 ± 2.4 years. Follow-up was complete in all. One 14-year old patient died 1.3 years post-surgery presumably of ventricular arrhythmia. One patient underwent reoperation for aneurysm of the proximal right coronary artery after 4.9 years and 4 patients required aortic valve replacement, 3 of which because of endocarditis after 0.1, 0.8 and 1.3 years and 1 because of cusp prolapse after 3.8 years. No thrombo-embolic complications occurred. Mortality, root reoperation and aortic regurgitation were absent in 88.0 ± 0.5% at 5-year follow-up. Results of valve-sparing root replacement are good, even in association with a high incidence of concomitant valve repair. Valve-sparing aortic root replacement can be performed at a very young age as long as an adult size prosthesis can be implanted. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  17. A review of digital radiography technology for valve inspection

    International Nuclear Information System (INIS)

    Stoev, K.; Guerout, F.M.; Horn, D.

    2008-01-01

    There are thousands of valves in a nuclear power plant (NPP) used for control, safety and checks in various plant systems, so there is a well-identified need for fast and reliable inspection and diagnostics of valves. Digital radiography can provide considerable improvements to the inspection and testing procedures for valves in comparison to classical film radiography. These improvements can lead to significant financial advantages by providing real-time inspection results, significantly reduced inspection and decision-making time, and reduced operational cost. Digital image processing, including digital image enhancement, digital archiving, and digital communication of the images and the results, is also a considerable advantage over classical film radiography technology. Another advantage of digital radiography technology is the improved safety and the reduced environmental impact due to reduced exposure/test times, use of smaller exclusion zones, elimination of chemical processing, and absence of disposable materials. This paper reviews the existing technology and evaluates the potential of digital radiography for inspection and diagnostics of valves. Station needs and requirements are assessed, and the safety, environmental and economical constraints of digital radiography techniques estimated. The advantages and disadvantages of different digital radiography equipment are compared, and their limitations and characteristics studied. (author)

  18. Survival and freedom from aortic valve-related reoperation after valve-sparing aortic root replacement in 1015 patients.

    Science.gov (United States)

    Kari, Fabian A; Doll, Kai-Nicolas; Hemmer, Wolfgang; Liebrich, Markus; Sievers, Hans-Hinrich; Richardt, Doreen; Reichenspurner, Hermann; Detter, Christian; Siepe, Matthias; Czerny, Martin; Beyersdorf, Friedhelm

    2016-04-01

    The aim of this study was to characterize mortality and aortic valve replacement after valve-sparing aortic root replacement (V-SARR) in a multicentre cohort. Between 1994 and 2014, 1015 patients had V-SARR with (n = 288, 28%) or without cusp/commissure repair (n = 727, 72%) at the centres of Lübeck (n = 343, 34%), Stuttgart (n = 346, 34%), Hamburg (n = 109, 11%) and Freiburg (n = 217, 21%), Germany. Comparative survival of an age- and gender-matched general population was calculated. Log-rank tests and multiple logistic regression were used to identify risk factors. The mean follow-up was 5.2 ± 3.9 years. Cumulative follow-up comprised 2933 patient-years. Early survival was 98%. NYHA status and aneurysm size were predictive of death during mid-term follow-up (P = 0.025). Freedom from aortic valve replacement was 90% at 8 years, with the type of V-SARR (root remodelling, David II) being a risk factor (P = 0.015). Bicuspid aortic valve (P = 0.26) and initial valve function (P = 0.4) did not impact reoperation. The need of additional valve repair (cusps/commissures) was not linked to reoperation: freedom from aortic valve replacement at 8 years was 84% if cusp repair was performed versus 90% if V-SARR alone was performed (P = 0.218). Marfan syndrome had no impact on survival or on aortic valve replacement. Mid-term survival of patients after V-SARR is comparable with that of a matched general population. The regurgitant bicuspid aortic valve is a favourable substrate for V-SARR. Prophylactic surgery should be performed before symptoms or large aneurysms are present to achieve optimal mid-term outcomes. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Development of advanced diagnostic technologies for motor-operated valves

    International Nuclear Information System (INIS)

    Hegi, Kotaro; Shimizu, Shunichi; Higuma, Koji; Nishino, Koji; Osaki, Kenji; Watanabe, Kazumi; Hamano, Frank

    2010-01-01

    As use of condition-based maintenance is allowed in the new regulatory inspection system employed in Japan's nuclear power plants in 2009, development of advanced diagnostic technologies for motor-operated valves (MOVs) is now required. This report discusses advanced technologies in valve-setup verification, valve performance evaluation, monitoring of valve/actuator conditions by performance diagnostic system and moreover detection of stem crack by ultrasonic diagnostic system. (author)

  20. Butterfly valve torque prediction methodology

    International Nuclear Information System (INIS)

    Eldiwany, B.H.; Sharma, V.; Kalsi, M.S.; Wolfe, K.

    1994-01-01

    As part of the Motor-Operated Valve (MOV) Performance Prediction Program, the Electric Power Research Institute has sponsored the development of methodologies for predicting thrust and torque requirements of gate, globe, and butterfly MOVs. This paper presents the methodology that will be used by utilities to calculate the dynamic torque requirements for butterfly valves. The total dynamic torque at any disc position is the sum of the hydrodynamic torque, bearing torque (which is induced by the hydrodynamic force), as well as other small torque components (such as packing torque). The hydrodynamic torque on the valve disc, caused by the fluid flow through the valve, depends on the disc angle, flow velocity, upstream flow disturbances, disc shape, and the disc aspect ratio. The butterfly valve model provides sets of nondimensional flow and torque coefficients that can be used to predict flow rate and hydrodynamic torque throughout the disc stroke and to calculate the required actuation torque and the maximum transmitted torque throughout the opening and closing stroke. The scope of the model includes symmetric and nonsymmetric discs of different shapes and aspects ratios in compressible and incompressible fluid applications under both choked and nonchoked flow conditions. The model features were validated against test data from a comprehensive flowloop and in situ test program. These tests were designed to systematically address the effect of the following parameters on the required torque: valve size, disc shapes and disc aspect ratios, upstream elbow orientation and its proximity, and flow conditions. The applicability of the nondimensional coefficients to valves of different sizes was validated by performing tests on 42-in. valve and a precisely scaled 6-in. model. The butterfly valve model torque predictions were found to bound test data from the flow-loop and in situ testing, as shown in the examples provided in this paper

  1. Crygenic performance of a superfluid helium relief valve for the LHC superconducting magnets

    International Nuclear Information System (INIS)

    Danielsson, H.; Ferlin, G.; Luguet, C.

    1996-01-01

    The high-field superconducting magnets of the Large Hadron Collider (LHC) project at CERN will operate below 1.9 K in static baths of pressurized helium II. In case of resistive transition (open-quotes quenchclose quotes), the resulting pressure rise in the cryostats must be limited to below their 2 MPa design pressure. This is achieved by discharging helium at high flow-rates into a cold recovery header, normally maintained at 20 K. For this purpose, the authors have designed, built and tested a cryogenic quench relief valve with a nominal diameter of 50 mm and an opening time of below 0.1 s. The valve, which can be opened on an external trigger, also acts as a relief device actuated by the upstream pressure when it exceeds 0.4 MPa. In normal operation, the closed poppet must be helium-tight, for hydraulic and thermal separation of the magnet baths from the recovery header. Following mechanical qualification tests under vacuum, the authors have mounted the relief valve in a dedicated cryogenic measuring bench, in order to perform precision thermal measurements with pressurized helium II

  2. Parameters Analysis of Hydraulic-Electrical Energy Regenerative Absorber on Suspension Performance

    Directory of Open Access Journals (Sweden)

    Han Zhang

    2014-05-01

    Full Text Available To recycle the vibration energy of vehicles over rough roads, a hydraulic-electricity energy regenerative suspension (HEERS was designed in the present work, and simulations were performed with focus on its performance. On the basis of the system principle, the mathematical model of hydraulic-electrical energy regenerative absorber (HEERA and two degrees of freedom (DOF suspension dynamic model were constructed. Using the model of HEERA, simulations on force-displacement and force-velocity characteristics were performed with a 1.67 Hz frequency and a sinusoidal input adopted. And then in combination with HEERA model and two DOF suspension models, simulations on the performance of HEERS also were carried out. Finally, the influences of charging pressure and volume of the accumulator, hydraulic motor displacement, orifice area of check valve, and inner diameter of hydraulic pipelines on the performance of HEERA and HEERS were investigated in depth. The simulation results indicated that (i the damping characteristic of HEERA was coincident with the damping characteristics of traditional absorber; (ii the most remarkable influencing factor on the performance of HEERS was the hydraulic motor displacement, followed by orifice area of check valve, inner diameter of pipelines, and charging pressure of accumulator, while the effects of charging volume of accumulator were quite limited.

  3. Flowfield Analysis of a Pneumatic Solenoid Valve

    Directory of Open Access Journals (Sweden)

    Sheam-Chyun Lin

    2018-07-01

    Full Text Available Pneumatic solenoid valve has been widely used in the vehicle control systems for meeting the rapid-reaction demand triggered by the dynamic conditions encountered during the driving course of vehicle. For ensuring the safety of human being, the reliable and effective solenoid valve is in great demand to shorten the reaction time and thus becomes the topic of this research. This numerical study chooses a commercial 3/2-way solenoid valve as the reference valve for analysing its performance. At first, CFD software Fluent is adopted to simulate the flow field associated with the valve configuration. Then, the comprehensive flow visualization is implemented to identify the locations of adverse flow patterns. Accordingly, it is found that a high-pressure region exists in the zone between the nozzle exit and the top of iron core. Thereafter, the nozzle diameter and the distance between nozzle and spool are identified as the important design parameters for improving the pressure response characteristics of valve. In conclusion, this work establishes a rigorous and systematic CFD scheme to evaluate the performance of pneumatic solenoid valve.

  4. Experimental assessment of valve performance in healthy and diseased right ventricular outflow tracts using magnetic resonance velocimetry

    Science.gov (United States)

    Schiavone, Nicole; Elkins, Christopher; McElhinney, Doff; Eaton, John K.; Marsden, Alison

    2017-11-01

    Tetralogy of Fallot (ToF), the most common type of cyanotic congenital heart defect, affects 1 in every 2500 newborns annually and typically requires surgical repair of the right ventricular outflow tract (RVOT) and placement of an artificial pulmonary valve. All artificial valves are subject to dysfunction, but their longevity is highly variable. Clinical observation reveals large variations in RVOT anatomy in ToF patients, which may affect longevity. This work aims to experimentally assess the performance of artificial pulmonary valves in anatomically realistic healthy and diseased RVOT geometries using magnetic resonance velocimetry (MRV). With MRV, we can capture 3D, three-component, phase-averaged velocity fields in 3D printed RVOT geometries. The experiment is designed to ensure physiological flow rate and pressure waveforms, while the RVOT geometries are based on anatomies seen clinically in ToF patients. Two models are used in the current work: an idealized RVOT based on healthy subjects aged eleven to thirteen and a diseased geometry with a dilation of 150% in vessel diameter downstream of the pulmonary valve. We will also present preliminary rigid-wall blood flow simulations in each model, towards the ultimate goal of experimental validation of valve simulations.

  5. Valve testing for UK PWR safety applications

    International Nuclear Information System (INIS)

    George, P.T.; Bryant, S.

    1989-01-01

    Extensive testing and development has been done by the Central Electricity Generating Board (CEGB) to support the design, construction and operation of Sizewell B, the UK's first PWR. A Blowdown Rig for the Assessment of Valve Operability - (BRAVO) has been constructed at the CEGB Marchwood Engineering Laboratory to reproduce PWR Pressurizer fluid conditions for the full scale testing of Pressurizer Relief System (PRS) valves. A full size tandem pair of Pilot Operated Safety Relief Valves (POSRVs) is being tested under the full range of pressurizer fluid conditions. Tests to date have produced important data on the performance of the valve in its Cold Overpressure protection mode of operation and on methods for the in-service testing of the valve. Also, a full size pressurizer safety valve has been tested under full PRS fluid conditions to develop a methodology for the pre-service testing of the Sizewell valves. Further work will be carried out to develop procedures for the in-service testing of the valve. In the Main Steam Safety Valve test program carried out at the Siemens-KWU Test Facilities, a single MSSV from three potential suppliers was tested under full secondary system conditions. The test results have been analyzed and are reflected in the CEGB's arrangements for the pre-service and in-service testing of the Sizewell MSSVs. Valves required to interrupt pipebreak flow must be qualified for this duty by testing or a combination of testing and analysis. To obtain guidance on the performance of such tests gate and globe valves have been subjected to simulated pipebreaks under PWR primary circuit conditions. In the light of problems encountered with gate valve closure under these conditions, further tests are currently being carried out on the BRAVO facility on a gate valve, in preparation for the full scale flow interruption qualification testing of the Sizewell main steam isolation valve

  6. A discussion of system reliability and the relative importance of pumps and valves to overall system availability

    Energy Technology Data Exchange (ETDEWEB)

    Poole, A.B. [Oak Ridge National Lab., TN (United States)

    1996-12-01

    An analysis was undertaken to establish preliminary trends for how component aging can effect failure rates for swing check valves, centrifugal pumps and motor operated valves. These failure rate trends were evaluated over time and linear aging rate models established. The failure rate models were then used with classic reliability theories to estimate reliability as a function of operating time. Reliability theory was also used to establish a simple system reliability model. Using the system model, the relative importance of pumps and valves to the overall system reliability were studied. Conclusions were established relative to overall system availability over time and the relative unavailabilities of the various components studied.

  7. A discussion of system reliability and the relative importance of pumps and valves to overall system availability

    International Nuclear Information System (INIS)

    Poole, A.B.

    1996-01-01

    An analysis was undertaken to establish preliminary trends for how component aging can effect failure rates for swing check valves, centrifugal pumps and motor operated valves. These failure rate trends were evaluated over time and linear aging rate models established. The failure rate models were then used with classic reliability theories to estimate reliability as a function of operating time. Reliability theory was also used to establish a simple system reliability model. Using the system model, the relative importance of pumps and valves to the overall system reliability were studied. Conclusions were established relative to overall system availability over time and the relative unavailabilities of the various components studied

  8. Theoretical study of a novel refrigeration compressor - Part II: Performance of a rotating discharge valve in the revolving vane (RV) compressor

    Energy Technology Data Exchange (ETDEWEB)

    Teh, Y.L.; Ooi, K.T. [Thermal and Fluids Engineering Division, School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, S639798 (Singapore); Djamari, D. Wibowo [Engineering Mechanics Division, School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, S639798 (Singapore)

    2009-08-15

    A new refrigeration compressor, named 'Revolving Vane (RV) compressor', has been introduced in Part I of this paper series. For a first time in refrigeration compressors, a rotating discharge valve is employed in the RV compressor mainly due to the rotation of the entire cylinder. This paper presents a theoretical investigation on the dynamic behavior of a reed-type discharge valve undergoing rotatory motion, with the primary objective of elucidating the applicability of such valves in refrigeration compressors. Under the application of the Euler-Bernoulli beam theory, a mathematical model of the rotating valve is formulated and the transient response of the valve under centrifugal loads in addition to pressure forces is analyzed. Results have shown that under careful design considerations, the performance as well as the reliability of the rotating discharge valve can be enhanced as compared to a non-rotating valve that has been used in all refrigeration compressors currently. (author)

  9. Research on Noise Reduction of Reed Valves of a Hermetic Refrigerator Compressor

    Science.gov (United States)

    He, Zhilong; Chen, Qian; Li, Dantong; Wang, Ju; Xia, Pu; Wang, Tao

    2017-08-01

    The noise level of the refrigerator compressor has received more and more attention in recent years. As the key component of a compressor, reed valve is its main noise source. In this paper, a new noise reduction technology of coating on reed valve surface is proposed and verified by experiments. Firstly, the reed valves were coated, and their surface characteristics were checked. Then, the refrigerator compressor p-V diagram test was carried out to investigate the influence of doped diamond-like carbon (DLC) coating on power consumption. Finally, the noise test rig for the refrigerator compressor was set up. Based on the standard test method, noise spectrum was measured in a semi-anechoic room under standard working condition. Research results showed that the compressor noise was significantly reduced by 1.8dB (A) after coating. Moreover, the effect of aerodynamic noise reduction at suction side is better than that at discharge side. However, the influence of the film thickness on noise reduction value is little. The COP was reduced by 0.6% as compared to the compressor with uncoated reed valves.

  10. Impact of patient-prosthesis mismatch after transcatheter aortic valve-in-valve implantation in degenerated bioprostheses.

    Science.gov (United States)

    Seiffert, Moritz; Conradi, Lenard; Baldus, Stephan; Knap, Malgorzata; Schirmer, Johannes; Franzen, Olaf; Koschyk, Dietmar; Meinertz, Thomas; Reichenspurner, Hermann; Treede, Hendrik

    2012-03-01

    Transcatheter valve-in-valve implantation is evolving as an alternative to reoperative valve replacement in high-risk patients with degenerated bioprostheses. Nevertheless, hemodynamic performance is limited by the previously implanted xenograft. We report our experience with patient-prosthesis mismatch (PPM) after valve-in-valve implantation in the aortic position. Eleven patients (aged 79.3 ± 6.1 years) received transapical implantation of a balloon-expandable pericardial heart valve into a degenerated bioprosthesis (size, 23.9 ± 1.6 mm; range, 21-27 mm) in the aortic position. All patients were considered high risk for surgical valve replacement (logistic European System for Cardiac Operative Risk Evaluation, 31.8% ± 24.1%). Severe PPM was defined as an indexed effective orifice area less than 0.65 cm(2)/m(2), determined by discharge echocardiography. Severe PPM was evident in 5 patients (group 1) and absent in 6 patients (group 2). Mean transvalvular gradients decreased from 29.2 ± 15.4 mm Hg before implantation to 21.2 ± 9.7 mm Hg at discharge (group 1) and from 28.2 ± 9.0 mm Hg before implantation to 15.2 ± 6.5 mm Hg at discharge (group 2). Indexed effective orifice area increased from 0.5 ± 0.1 cm(2)/m(2) to 0.6 ± 0.1 cm(2)/m(2) and from 0.6 ± 0.3 cm(2)/m(2) to 0.8 ± 0.3 cm(2)/m(2). Aortic regurgitation decreased from grade 2.0 ± 1.1 to 0.4 ± 0.5 overall. No differences in New York Heart Association class improvement or survival during follow-up were observed. One patient required reoperation for symptomatic PPM 426 days after implantation. Valve-in-valve implantation can be performed in high-risk surgical patients to avoid reoperation. However, PPM frequently occurs, making adequate patient selection crucial. Small bioprostheses (body surface area less than 1.8 m(2). Larger prostheses seem to carry a lower risk for PPM. Although no delay in clinical improvement was seen at short-term, 1 PPM-related surgical intervention raises concern regarding

  11. Quadricuspid pulmonic valve found on well exam

    Institute of Scientific and Technical Information of China (English)

    Stephen N Dunay; Roberta Roberge; Lena Savedissian

    2015-01-01

    Quadricuspid pulmonic valve (QPV) is almost always a benign anomaly and is therefore usually discovered incidentally on radiographic studies or post-mortem at autopsy. Because of its rarity, the true extent of the physiology of QPV is not fully understood, and the few reported cases of it may underestimate its physiological consequences. In this case, we report on a young active-duty solider who presented for a well check-up and was discovered on imaging to have a QPV. We also review the most recent literature and provide recommendations regarding the most effective diagnostic modalities.

  12. Charging valve of the full hydraulic braking system

    Directory of Open Access Journals (Sweden)

    Jinshi Chen

    2016-03-01

    Full Text Available It is known that the full hydraulic braking system has excellent braking performance. As the key component of the full hydraulic braking system, the parameters of the accumulator charging valve have a significant effect on the braking performance. In this article, the key parameters of the charging valve are analyzed through the static theoretical and an Advanced Modeling Environment for performing Simulation of engineering systems (AMESim simulation model of the dual-circuit accumulator charging valve is established based on the real structure parameters first. Second, according to the results of the dynamic simulation, the dynamic characteristics of the charging pressure, the flow rate, and the frequency of the charging valve are studied. The key parameters affecting the serial production are proposed and some technical advices for improving the performance of the full hydraulic system are provided. Finally, the theoretical analysis is validated by the simulation results. The comparison between the simulation results and the experimental results indicates that the simulated AMESim model of the charging valve is accurate and credible with the error rate inside 0.5% compared with the experimental result. Hence, the performance of the charging valve meets the request of the full hydraulic braking system exactly.

  13. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    Directory of Open Access Journals (Sweden)

    Harish Ramakrishna

    2015-01-01

    Full Text Available Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.

  14. Leaving Moderate Tricuspid Valve Regurgitation Alone at the Time of Pulmonary Valve Replacement: A Worthwhile Approach.

    Science.gov (United States)

    Kogon, Brian; Mori, Makoto; Alsoufi, Bahaaldin; Kanter, Kirk; Oster, Matt

    2015-06-01

    postoperative month after pulmonary valve replacement, irrespective of concomitant tricuspid valve annuloplasty. The tricuspid valve appears to function better over the midterm if annuloplasty is not performed. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Optimal results of aortic valve replacement with small mechanical valves (< 19 mm).

    Science.gov (United States)

    Kato, Yasuyuki; Hattori, Koji; Motoki, Manabu; Takahashi, Yosuke; Kotani, Shinsuke; Nishimura, Shinsuke; Shibata, Toshihiko

    2013-07-01

    Controversy exists regarding the optimal operative method or type of prosthesis for patients with a small aortic root. The aim of this retrospective study was to investigate the early and mid-term outcomes of standard aortic valve replacement (AVR) using 16 mm or 18 mm ATS Advanced Performance (AP) or 17 mm St. Jude Medical (SJM) Regent valves for a small aortic root. Between April 2003 and August 2009, 78 patients (age range: 50-86 years; 86% aged > or = 65 years) underwent AVR with 16 mm or 18 mm ATS AP valves (16AP group: n = 21, 18AP group: n = 32), or a 17 mm SJM Regent valve (17Regent group: n = 25). Fifty-six patients (72%) had a body surface area (BSA) of regression was similar among the groups (-30%, -25% and -28% in the 16AP, 17Regent and 18AP groups, respectively; p = 0.844). The early and mid-term results of AVR with 16 mm or 18 mm ATS AP valves, or with a 17 mm SJM Regent valve, were satisfactory. Therefore, standard AVR using these small mechanical prostheses, which avoids the need to enlarge the annulus or to conduct stentless bioprosthesis implantation, might represent an acceptable method, especially in elderly patients with a small aortic root.

  16. A new one-step procedure for pulmonary valve implantation of the melody valve: Simultaneous prestenting and valve implantation.

    Science.gov (United States)

    Boudjemline, Younes

    2018-01-01

    To describe a new modification, the one-step procedure, that allows interventionists to pre-stent and implant a Melody valve simultaneously. Percutaneous pulmonary valve implantation (PPVI) is the standard of care for managing patients with dysfunctional right ventricular outflow tract, and the approach is standardized. Patients undergoing PPVI using the one-step procedure were identified in our database. Procedural data and radiation exposure were compared to those in a matched group of patients who underwent PPVI using the conventional two-step procedure. Between January 2016 and January 2017, PPVI was performed in 27 patients (median age/range, 19.1/10-55 years) using the one-step procedure involving manual crimping of one to three bare metal stents over the Melody valve. The stent and Melody valve were delivered successfully using the Ensemble delivery system. No complications occurred. All patients had excellent hemodynamic results (median/range post-PPVI right ventricular to pulmonary artery gradient, 9/0-20 mmHg). Valve function was excellent. Median procedural and fluoroscopic times were 56 and 10.2 min, respectively, which significantly differed from those of the two-step procedure group. Similarly, the dose area product (DAP), and radiation time were statistically lower in the one-step group than in the two-step group (P step procedure is a safe modification that allows interventionists to prestent and implants the Melody valve simultaneously. It significantly reduces procedural and fluoroscopic times, and radiation exposure. © 2017 Wiley Periodicals, Inc.

  17. Control characteristics and heating performance analysis of automatic thermostatic valves for radiant slab heating system in residential apartments

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byung-Cheon [Department of Building Equipment System Engineering, Kyungwon University, Seongnam City (Korea); Song, Jae-Yeob [Graduate School, Building Equipment System Engineering, Kyungwon University, Seongnam City (Korea)

    2010-04-15

    Computer simulations and experiments are carried out to research the control characteristics and heating performances for a radiant slab heating system with automatic thermostatic valves in residential apartments. An electrical equivalent R-C circuit is applied to analyze the unsteady heat transfer in the house. In addition, the radiant heat transfer between slabs, ceilings and walls in the room is evaluated by enclosure analysis method. Results of heating performance and control characteristics were determined from control methods such as automatic thermostatic valves, room air temperature-sensing method, water-temperature-sensing method, proportional control method, and On-Off control method. (author)

  18. Valve Corporation: Strategy Tipping Points and Thresholds

    OpenAIRE

    Teppo Felin

    2015-01-01

    Valve Corporation represents an intriguing case study of flat structure and self organization (Puranam & Håkonsson, 2015; Valve, 2012).  The structures and practices of Valve of course are not new. But the company provides an interesting experiment and illustration that powerfully highlights how organizational design can impact individual and collective behavior, strategy and performance.

  19. Maintenance planning and performance software for valve packing programs at nuclear power stations (ValvePro Version 2.5)

    International Nuclear Information System (INIS)

    Hutcheson, N.D.

    1994-01-01

    ValvePro Version 2.5 for Windows was developed to help power plant maintenance personnel improve maintenance productivity and quality through a simple, attractive software program, which can be installed on personal computer systems in use at many utilities today. This paper explains the functions of this software and how it can be used by a maintenance organization as a foundation for a consistent, effective valve packing program utilizing sound packing principles

  20. Factors influencing left ventricular outflow tract obstruction following a mitral valve-in-valve or valve-in-ring procedure, part 1.

    Science.gov (United States)

    Bapat, Vinnie; Pirone, Francesco; Kapetanakis, Stam; Rajani, Ronak; Niederer, Steven

    2015-10-01

    To determine the factors influencing left ventricular outflow tract (LVOT) area reduction after a mitral valve-in-valve (VIV) or a valve-in-ring (VIR) procedure. Transcatheter heart valves (THVs) are increasingly used in performing a VIV or a VIR procedure in high-risk patients. Although less invasive, a potential complication is LVOT obstruction. However, the factors predisposing to LVOT obstruction are ill defined. To understand the effects of the various factors, the study was carried out in three parts: To understand the effect of VIV and VIR on reduction in LVOT area with special attention to different surgical heart valve (SHV) orientations and depth of THV implant. This was carried out in porcine and cadaver hearts. To quantify aorto-mitral-annular (AMA) angle in 20 patients with or without mitral disease and to derive a static computational model to predict LVOT obstruction. To study the effect of SHV design on LVOT obstruction after VIV. This was carried out as a bench test. LVOT area reduction was similar after VIV irrespective of orientation of the mitral SHV implantation as it pinned open the SHV leaflets. Similar effect was seen after VIR. The degree of LVOT obstruction was partly determined by AMAangle and was inversely proportional. SHV design, ring design, and depth of SPAIEN XT implantation also had effect on LVOT obstruction. A possibility of LVOT obstruction should be considered when performing a VIV and VIR procedure. Type of SHV, flexible ring, less obtuse AMA angle, and depth of SAPIEN XT implant can influence the risk. © 2015 Wiley Periodicals, Inc.

  1. Aortic Root Enlargement or Sutureless Valve Implantation?

    Directory of Open Access Journals (Sweden)

    Nikolaos G. Baikoussis

    2016-11-01

    Full Text Available Aortic valve replacement (AVR in patients with a small aortic annulus is a challenging issue. The importance of prosthesis–patient mismatch (PPM post aortic valve replacement (AVR is controversial but has to be avoided. Many studies support the fact that PPM has a negative impact on short and long term survival. In order to avoid PPM, aortic root enlargement may be performed. Alternatively and keeping in mind that often some comorbidities are present in old patients with small aortic root, the Perceval S suturelles valve implantation could be a perfect solution. The Perceval sutureless bioprosthesis provides reasonable hemodynamic performance avoiding the PPM and providing the maximum of aortic orifice area. We would like to see in the near future the role of the aortic root enlargement techniques in the era of surgical implantation of the sutureless valve (SAVR and the transcatheter valve implantation (TAVI.

  2. Valve Corporation: Strategy Tipping Points and Thresholds

    Directory of Open Access Journals (Sweden)

    Teppo Felin

    2015-06-01

    Full Text Available Valve Corporation represents an intriguing case study of flat structure and self organization (Puranam & Håkonsson, 2015; Valve, 2012.  The structures and practices of Valve of course are not new. But the company provides an interesting experiment and illustration that powerfully highlights how organizational design can impact individual and collective behavior, strategy and performance.

  3. Gate valve and motor-operator research findings

    International Nuclear Information System (INIS)

    Steele, R. Jr.; DeWall, K.G.; Watkins, J.C.; Russell, M.J.; Bramwell, D.

    1995-09-01

    This report provides an update on the valve research being sponsored by the US Nuclear Regulatory Commission (NRC) and conducted at the Idaho National Engineering Laboratory (INEL). The research addresses the need to provide assurance that motor-operated valves can perform their intended safety function, usually to open or close against specified (design basis) flow and pressure loads. This report describes several important developments: Two methods for estimating or bounding the design basis stem factor (in rising-stem valves), using data from tests less severe than design basis tests; a new correlation for evaluating the opening responses of gate valves and for predicting opening requirements; an extrapolation method that uses the results of a best effort flow test to estimate the design basis closing requirements of a gate valve that exhibits atypical responses (peak force occurs before flow isolation); and the extension of the original INEL closing correlation to include low- flow and low-pressure loads. The report also includes a general approach, presented in step-by-step format, for determining operating margins for rising-stem valves (gate valves and globe valves) as well as quarter-turn valves (ball valves and butterfly valves)

  4. Study of typical nuclear containment purge valves in an accident environment

    International Nuclear Information System (INIS)

    Watkins, J.C.; Steele, R. Jr.; Hill, R.C.; DeWall, K.G.

    1986-08-01

    This report presents the results of the containment purge and vent valve test program, conducted under the sponsorship of the United States Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research. The test program investigated butterfly valve operability and leak integrity under light-water-reactor design basis and severe accident conditions. Three nuclear-designed butterfly valves typical of those used in domestic nuclear power plant containment purge and vent applications were tested. For a comparison of response, two valve of the same size with differing internal designs were tested. For extrapolation insights, a larger-sized valve similar to one of the smaller valves was also tested. Dynamic flow tests were performed over the range of design basis accident pressures. Leak integrity testing was also performed at both design basis and severe accident temperatures and pressures. The valve experiments were performed with various piping configurations and valve orientations to the flow to simulate the various installation options in field applications. Testing was also performed in a standard ANSI test section

  5. Latest design of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kurzhofer, U.; Stolte, J.; Weyand, M.

    1996-12-01

    Babcock Sempell, one of the most important valve manufacturers in Europe, has delivered valves for the nuclear power industry since the beginning of the peaceful application of nuclear power in the 1960s. The latest innovation by Babcock Sempell is a gate valve that meets all recent technical requirements of the nuclear power technology. At the moment in the United States, Germany, Sweden, and many other countries, motor-operated gate and globe valves are judged very critically. Besides the absolute control of the so-called {open_quotes}trip failure,{close_quotes} the integrity of all valve parts submitted to operational forces must be maintained. In case of failure of the limit and torque switches, all valve designs have been tested with respect to the quality of guidance of the gate. The guidances (i.e., guides) shall avoid a tilting of the gate during the closing procedure. The gate valve newly designed by Babcock Sempell fulfills all these characteristic criteria. In addition, the valve has cobalt-free seat hardfacing, the suitability of which has been proven by friction tests as well as full-scale blowdown tests at the GAP of Siemens in Karlstein, West Germany. Babcock Sempell was to deliver more than 30 gate valves of this type for 5 Swedish nuclear power stations by autumn 1995. In the presentation, the author will report on the testing performed, qualifications, and sizing criteria which led to the new technical design.

  6. Characteristic analysis and experiment of pneumatic servo valve

    International Nuclear Information System (INIS)

    Kim, Dong Soo; Lee, Won Hee; Choi, Byung Oh

    2004-01-01

    Electro-pneumatic servo valve is an electro-mechanical device which converts electric signals into a proper pneumatic flow rate or pressure. In order to improve the overall performance of pneumatic servo systems, electro-pneumatic servo valves are required, which have fast dynamic characteristics, no air leakage at a null point, and can be fabricated at a low-cost. The first objective of this research is to design and to fabricate a new electro-pneumatic servo valve which satisfies the above-mentioned requirements. In order to design the mechanism of the servo valve optimally, the flow inside the valve depending upon the position of spool was analyzed variously, and on the basis of such analysis results, the valve mechanism, which was formed by combination of the spool and the sleeve, was designed and manufactured. And a tester for conducting an overall performance test was designed and manufactured, and as a result of conducting the flow rate test, the pressure test and the frequency test on the developed pneumatic servo valve

  7. Function analysis of steam isolation valves

    International Nuclear Information System (INIS)

    Persson, R.; Kilpi, K.; Noro, H.; Siikonen, T.; Sjoeberg, A.; Wallen, G.; Aakesson, H.

    1981-01-01

    Function analysis of system-medium-operated steam isolation valves has been the objective of the Swedish-Finnish IVLS project, the results of which are presented in this report. Theoretical models were to be verified against available experimental data, to some extent from the HDR blowdown experiments, which are part of a German reactor safety program. Finnish hydraulic measurements on a valve model (scale 1:2.15) have been performed to give complementary data. The analysis work has covered the thermal-hydraulic behaviour of steam isolation valves as well as phenomena related to structural mechanics. Work performed under contract with the Swedish Nuclear Power Inspectorate. (Author)

  8. Heart valve surgery

    Science.gov (United States)

    ... replacement; Valve repair; Heart valve prosthesis; Mechanical valves; Prosthetic valves ... surgery. Your heart valve has been damaged by infection ( endocarditis ). You have received a new heart valve ...

  9. Durability Tests of Ball Valve Prototype with Flowmeter Operation

    Science.gov (United States)

    Rogula, J.; Romanik, G.

    2018-02-01

    The results of the investigation of the prototypical ball valve are presented in this article. The innovation of the tested valve is a ball with a built-in measuring orifice. The valve has been subjected to durability tests. Leakage under three temperatures: ambient, -30°C and +100°C was analyzed. Sealing elements of the valve were tested for roughness and deviation of shape before and after the cycles of operation. Ball valve operation means cycles of open/close. It was planned to perform 1000 cycles at each temperature condition accordingly. Tests of the valve were performed under gas pressure equal to 10 MPa. The research was carried out under the Operational Program "Intelligent Development" (POIR 01.01.01-00-0013 / 15 "Development of devices for measurement of media flow on industrial trunk-lines".

  10. Valve packing manual. A maintenance application guide

    International Nuclear Information System (INIS)

    Aikin, J.A.; McCutcheon, R.G.; Cumming, D.

    1997-01-01

    Since 1970, AECL Chalk River Mechanical Equipment Development (MED) branch has invested over 175 person years in testing related to improving valve packing performance. Successful developments, including, 'live-loading', reduced packing heights, and performance-based packing qualification testing have been implemented. Since 1986, MED and the Integrated Valve Actuator Program Task Force - Valve Packing Steering Committee (IVAP-VPSC) have been involved in the development of combination die-formed graphite packing for use in CANDU plants. Many reports, articles, and specifications have been issued. Due to the large amount of test data and reports, a more user-friendly document has been prepared for everyday use. The Valve Packing Manual is based on many years of MED research and testing, as well as operating experience from CANDU nuclear generating stations (NGS). Since 1986, packing research and testing has been funded by the CANDU Owners Group (COG), the Electric Power Research Institute (EPRI), and participating valve packing manufacturers. The Valve Packing Manual (VPM) provides topical summaries of all work related to valve packing done since 1985. It includes advances in configuration design, stem packing friction, materials specifications, and installation procedures. This paper provides an overview on the application of the VPM with a focus on qualification testing, packing configuration, and stem packing friction. (author)

  11. Reduction of shunt current in buffer-free IrMn based spin-valve structures

    Science.gov (United States)

    Kocaman, B.; Akdoğan, N.

    2018-06-01

    The presence of thick buffer layers in magnetic sensor devices decreases sensor sensitivity due to shunt currents. With this motivation, we produced IrMn-based spin-valve multilayers without using buffer layer. We also studied the effects of post-annealing and IrMn thickness on exchange bias field (HEB) and blocking temperature (TB) of the system. Magnetization measurements indicate that both HEB and TB values are significantly enhanced with post-annealing of IrMn layer. In addition, we report that IrMn thickness of the system strongly influences the magnetization and transport characteristics of the spin-valve structures. We found that the minimum thickness of IrMn layer is 6 nm in order to achieve the lowest shunt current and high blocking temperature (>300 K). We also investigated the training of exchange bias to check the long-term durability of IrMn-based spin-valve structures for device applications.

  12. Research on digital system design of nuclear power valve

    Science.gov (United States)

    Zhang, Xiaolong; Li, Yuan; Wang, Tao; Dai, Ye

    2018-04-01

    With the progress of China's nuclear power industry, nuclear power plant valve products is in a period of rapid development, high performance, low cost, short cycle of design requirements for nuclear power valve is proposed, so there is an urgent need for advanced digital design method and integrated design platform to provide technical support. Especially in the background of the nuclear power plant leakage in Japan, it is more practical to improve the design capability and product performance of the nuclear power valve. The finite element numerical analysis is a common and effective method for the development of nuclear power valves. Nuclear power valve has high safety, complexity of valve chamber and nonlinearity of seal joint surface. Therefore, it is urgent to establish accurate prediction models for earthquake prediction and seal failure to meet engineering accuracy and calculation conditions. In this paper, a general method of finite element modeling for nuclear power valve assembly and key components is presented, aiming at revealing the characteristics and rules of finite element modeling of nuclear power valves, and putting forward aprecision control strategy for finite element models for nuclear power valve characteristics analysis.

  13. Development of multilayer piezoelectric actuator valve for JT-60

    International Nuclear Information System (INIS)

    Miyo, Yasuhiko; Hiratsuka, Hajime; Masui, Hiroshi; Hosogane, Nobuyuki; Miya, Naoyuki

    2001-11-01

    In order to improve the gas injection valve used for the operation of JT-60, a new type of valve (multilayer piezoelectric actuator valve) was developed. The conventional valve (bimorph piezoelectric valve) has been used for 15 years since the beginning of experimental operation in April, 1985. However, it came to be hard to keep the performance of the valve because of the deterioration of the driving source, i.e. piezoelectric element. Developments of the new valve were carried out based on experiences through experimental operations in JT-60. Requirements for the design are: (1) to be hard structure for making a sheet leak, (2) to allow a repair work at atmosphere side without an air vent of the vacuum vessel, (3) to be more smaller and lighter compared with the conventional one, and (4) to have a high maintenance efficiency by utilizing of the commercial piezoelectric elements and power supplies. The newly developed valve was examined with various tests such as gas flow characteristic test, high magnetic field proof test, high temperature proof test and gas flow rate test for aged deterioration. Results, confirm that the performance of the valve is applicable for JT-60 operations. (author)

  14. Software development for simplified performance tests and weekly performance check in Younggwang NPP Unit 3 and 4

    International Nuclear Information System (INIS)

    Hur, K. Y.; Jang, S. H.; Lee, J. W.; Kim, J. T.; Park, J. C.

    2002-01-01

    This paper covers the current status of turbine cycle performance test in nuclear power plants and the software development which can solve some shortcomings related to performance tests. The software developed is for simplified performance tests and weekly performance checks in Yonggwang nuclear power plant unit 3 and 4. This software includes the requirements from the efficiency division for the consistency with actual performance analysis work and the usability of the collected performance test data. From the working survey, we identify the difference between the embedded performance analysis modules and the actual performance analysis work. This software helps operation or maintenance personnel to reduce work load, to support the trend analysis of essential parameters in a turbine cycle, and to utilize the correction curves for the decision-making in their work

  15. Dynamic Characteristics Analysis of Power Shift Control Valve

    Directory of Open Access Journals (Sweden)

    Feng Ren

    2014-07-01

    Full Text Available In order to study the influence that dynamic performance of shift control valve has on shifting process of construction machinery, the paper introduces working principle of the shift control valve and sets up the dynamically mathematical model and corresponding simulation model with simulation software LMS Imagine. Lab AMESim. Based on simulation, the paper analyzes the influence of pressure variation characteristics and buffering characteristics acting on vehicle performance during the process of shifting, meanwhile conducting experiments to verify the simulation. The results indicate that the simulation model is accurate and credible; the performance of the valve is satisfactory, which indeed reduces impact during shifting. Furthermore, the valve can meet the demand of other construction machineries in better degree by suitable matching between control spring stiffness and damping holes diameter.

  16. Is valve choice a significant determinant of paravalular leak post-transcatheter aortic valve implantation? A systematic review and meta-analysis.

    Science.gov (United States)

    O'Sullivan, Katie E; Gough, Aideen; Segurado, Ricardo; Barry, Mitchel; Sugrue, Declan; Hurley, John

    2014-05-01

    Paravalvular regurgitation (PVR) following transcatheter aortic valve implantation (TAVI) is associated with poor survival. The two main valve delivery systems used to date differ significantly in both structure and deployment technique. The primary objective of this study was to perform a systematic review and meta-analysis of studies identifying PVR in patients post-TAVI using Medtronic CoreValve (MCV) and Edward Sapien (ES) valves in order to identify whether a significant difference exists between valve types. The secondary objective was to identify additional factors predisposing to PVR to provide an overview of the other associated considerations. A systematic review and meta-analysis of the current literature to identify PVR rate in patients with MCV and ES valves was performed. We also sought to examine other factors predisposing to PVR. A total of 5910 patients were identified from 9 studies. PVR rates for MCV and ES were analysed. MCV was associated with a higher PVR rate of 15.75% [95% confidence interval (CI) 12.48-19.32] compared with ES 3.93% [95% CI 1.05-8.38]. We separately reviewed predisposing factors associated with PVR. A formal comparison of the MCV and ES valve leakage rates by mixed-effects meta-regression with a fixed-effect moderator variable for valve type (MCV or ES) suggested a statistically significant difference in leakage rate between the two valve types (P = 0.0002). Unfavourable anatomical and pathological factors as well as valve choice have an impact on rates of PVR. Additionally, certain anatomical features dictate valve choice. A direct comparison of all the predisposing factors at this time is not possible and will require prospective multivariate analysis. There is, however, a significant difference in the PVR rates between valves based on the published observational data available to date. The ES valve associated with a lower incidence of PVR overall; therefore, we conclude that valve choice is indeed a significant

  17. Multifunctional four-port directional control valve constructed from logic valves

    International Nuclear Information System (INIS)

    Lisowski, E.; Czyżycki, W.; Rajda, J.

    2014-01-01

    Highlights: • Directional valve with standard ISO 440-08 has been constructed from logic valves. • Only one innovative valve may replace whole family of the standard valves. • CFD analysis and bench tests of the innovative valve has been carried. • Parameters of the innovative valve are equaling or surpassing the standard ones. • The innovative valve has additional possibilities of pressure and flow control. - Abstract: The paper refers to four-port solenoid pilot operated valves, which are subplate mounted in a hydraulic system in accordance with the ISO 4401 standard. Their widespread use in many machines and devices causes a continuing interest in the development of their design by both the scientific centers and the industry. This paper presents an innovative directional control valve based on the use of logic valves and a methodology followed for the design of it by using Solid Edge CAD and ANSYS/Fluent CFD software. The valve design methodology takes into account the need to seek solutions that minimize flow resistance through the valve. For this purpose, the flow paths are prepared by means of CAD software and pressure-flow curves are determined as a result of CFD analysis. The obtained curves are compared with the curves available in the catalogs of spool type directional control valves. The new solution allows to replace the whole family of spool type four-port directional control valves by one valve built of logic valves. In addition, the innovative directional control valve provides leak-proof shutting the flow paths off and also it can control flow rate and even pressure of working liquid. A prototype of the valve designed by the presented method has been made and tested on the test bench. The results quoted in the paper confirm that the developed logic type directional control valve is able to meet all designed connection configurations, and the obtained pressure-flow curves show very good conformity with the results of CFD analysis

  18. Full-root aortic valve replacement with stentless xenograft achieves superior regression of left ventricular hypertrophy compared to pericardial stented aortic valves.

    Science.gov (United States)

    Tavakoli, Reza; Auf der Maur, Christoph; Mueller, Xavier; Schläpfer, Reinhard; Jamshidi, Peiman; Daubeuf, François; Frossard, Nelly

    2015-02-03

    Full-root aortic valve replacement with stentless xenografts has potentially superior hemodynamic performance compared to stented valves. However, a number of cardiac surgeons are reluctant to transform a classical stented aortic valve replacement into a technically more demanding full-root stentless aortic valve replacement. Here we describe our technique of full-root stentless aortic xenograft implantation and compare the early clinical and midterm hemodynamic outcomes to those after aortic valve replacement with stented valves. We retrospectively compared the pre-operative characteristics of 180 consecutive patients who underwent full-root replacement with stentless aortic xenografts with those of 80 patients undergoing aortic valve replacement with stented valves. In subgroups presenting with aortic stenosis, we further analyzed the intra-operative data, early postoperative outcomes and mid-term regression of left ventricular mass index. Patients in the stentless group were younger (62.6 ± 13 vs. 70.3 ± 11.8 years, p regression of the left ventricular mass index in the stentless (p replacement can be performed without adversely affecting the early morbidity or mortality in patients operated on for aortic valve stenosis provided that the coronary ostia are not heavily calcified. The additional time necessary for the full-root stentless compared to the classical stented aortic valve replacement is therefore not detrimental to the early clinical outcomes and is largely rewarded in patients with aortic stenosis by lower transvalvular gradients at mid-term and a better regression of their left ventricular mass index.

  19. The Double-Orifice Valve Technique to Treat Tricuspid Valve Incompetence.

    Science.gov (United States)

    Hetzer, Roland; Javier, Mariano; Delmo Walter, Eva Maria

    2016-01-01

    A straightforward tricuspid valve (TV) repair technique was used to treat either moderate or severe functional (normal valve with dilated annulus) or for primary/organic (Ebstein's anomaly, leaflet retraction/tethering and chordal malposition/tethering, with annular dilatation) TV incompetence, and its long-term outcome assessed. A double-orifice valve technique was employed in 91 patients (mean age 52.6 ± 23.2 years; median age 56 years; range: 0.6-82 years) with severe tricuspid regurgitation. Among the patients, three had post-transplant iatrogenic chordal rupture, five had infective endocarditis, 11 had mitral valve insufficiency, 23 had Ebstein's anomaly, and 47 had isolated severe TV incompetence. The basic principle was to reduce the distance between the coapting leaflets, wherein the most mobile leaflet could coapt to the opposite leaflet, by creating two orifices, ensuring valve competence. The TV repair was performed through a median sternotomy or right anterior thoracotomy in the fifth intercostal space under cardiopulmonary bypass. The degree and extent of creating a double-valve orifice was determined by considering the minimal body surface area (BSA)-related acceptable TV diameter. Repair was accomplished by passing pledgeted mattress sutures from the middle of the true anterior annulus to a spot on the opposite septal annulus, located approximately two-thirds of the length of the septal annulus to avoid injury to the bundle of His. The annular apposition divides the TV into a larger anterior and a smaller posterior orifices, enabling valve closure, on both sides. In adults, the diameter of the anterior valve orifice should be 23-25 mm, and the posterior orifice 15-18 mm; thus, the total valve orifice area is 5-6 cm2. In children, the total valve orifice should be a standard deviation of 1.7 mm for a BSA of 1.0m2. During a mean follow up of 8.7 ± 1.34 years (median 10 years; range: 1.5-25.9 years) there have been no reoperations for TV insufficiency

  20. Is valve choice a significant determinant of paravalular leak post-transcatheter aortic valve implantation? A systematic review and meta-analysis.

    LENUS (Irish Health Repository)

    O'Sullivan, Katie E

    2013-11-01

    Paravalvular regurgitation (PVR) following transcatheter aortic valve implantation (TAVI) is associated with poor survival. The two main valve delivery systems used to date differ significantly in both structure and deployment technique. The primary objective of this study was to perform a systematic review and meta-analysis of studies identifying PVR in patients post-TAVI using Medtronic CoreValve (MCV) and Edward Sapien (ES) valves in order to identify whether a significant difference exists between valve types. The secondary objective was to identify additional factors predisposing to PVR to provide an overview of the other associated considerations.

  1. Control Valve

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Wayne R.

    2018-03-20

    A control valve includes a first conduit having a first inlet and a first outlet and defining a first passage; a second conduit having a second inlet and a second outlet and defining a second passage, the second conduit extending into the first passage such that the second inlet is located within the first passage; and a valve plate disposed pivotably within the first passage, the valve plate defining a valve plate surface. Pivoting of the valve plate within the first passage varies flow from the first inlet to the first outlet and the valve plate is pivotal between a first position and a second position such that in the first position the valve plate substantially prevents fluid communication between the first passage and the second passage and such that in the second position the valve plate permits fluid communication between the first passage and the second passage.

  2. Carotenoids co-localize with hydroxyapatite, cholesterol, and other lipids in calcified stenotic aortic valves. Ex vivo Raman maps compared to histological patterns.

    OpenAIRE

    Bonetti, A.; Bonifacio, A.; Della Mora, A.; Livi, U.; Marchini, M.; Ortolani, F.

    2015-01-01

    Unlike its application for atherosclerotic plaque analysis, Raman microspectroscopy was sporadically used to check the sole nature of bioapatite deposits in stenotic aortic valves, neglecting the involvement of accumulated lipids/lipoproteins in the calcific process. Here, Raman microspectroscopy was employed for examination of stenotic aortic valve leaflets to add information on nature and distribution of accumulated lipids and their correlation with mineralization in the light of its potent...

  3. MEMS Micro-Valve for Space Applications

    Science.gov (United States)

    Chakraborty, I.; Tang, W. C.; Bame, D. P.; Tang, T. K.

    1998-01-01

    We report on the development of a Micro-ElectroMechanical Systems (MEMS) valve that is designed to meet the rigorous performance requirements for a variety of space applications, such as micropropulsion, in-situ chemical analysis of other planets, or micro-fluidics experiments in micro-gravity. These systems often require very small yet reliable silicon valves with extremely low leak rates and long shelf lives. Also, they must survive the perils of space travel, which include unstoppable radiation, monumental shock and vibration forces, as well as extreme variations in temperature. Currently, no commercial MEMS valve meets these requirements. We at JPL are developing a piezoelectric MEMS valve that attempts to address the unique problem of space. We begin with proven configurations that may seem familiar. However, we have implemented some major design innovations that should produce a superior valve. The JPL micro-valve is expected to have an extremely low leak rate, limited susceptibility to particulates, vibration or radiation, as well as a wide operational temperature range.

  4. Feasibility of Valve-in-Valve Procedure for Degenerated St. Jude Medical Trifecta Bioprosthesis.

    Science.gov (United States)

    Verhoye, Jean-philippe; Harmouche, Majid; Soulami, Reda Belhaj; Thebault, Christophe; Boulmier, Dominique; Leguerrier, Alain; Anselmi, Amedeo

    2015-07-01

    The valve-in-valve (ViV) procedure is an option for patients with symptomatic structural degeneration of a bioprosthesis and excessive reoperative risk. The risk of coronary obstruction appears to be increased if ViV is performed for certain pericardial prostheses in which the leaflets are mounted outside the stent posts. Herein is described a successful ViV for a degenerated Trifecta aortic bioprosthesis, and the technical considerations for performing a ViV procedure within such types of prosthesis are considered. Emphasis is placed on the importance of preoperative investigations (computed tomography scan-based measurements of coronary ostial height and of sinus of Valsalva diameters), and on the precise deployment of the valve (transapical approach with transesophageal echocardiography control) to minimize the risk of major complications. The presence of a failing Trifecta bioprosthesis should not be considered an absolute contraindication to ViV on the basis of the risk of coronary obstruction.

  5. Aortic Regurgitation in Patients Undergoing Transcatheter Aortic Valve Replacement With the Self-Expanding CoreValve Versus the Balloon-Expandable SAPIEN XT Valve.

    Science.gov (United States)

    Kiramijyan, Sarkis; Magalhaes, Marco A; Koifman, Edward; Didier, Romain; Escarcega, Ricardo O; Baker, Nevin C; Negi, Smita I; Minha, Sa'ar; Torguson, Rebecca; Jiaxiang, Gai; Asch, Federico M; Wang, Zuyue; Okubagzi, Petros; Gaglia, Michael A; Ben-Dor, Itsik; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2016-05-01

    The incidence of aortic regurgitation (AR) after transcatheter aortic valve replacement (TAVR) in a self-expanding and a balloon-expandable system is controversial. This study aimed to examine the incidence and severity of post-TAVR AR with the CoreValve (CV) versus the Edwards XT Valve (XT). Baseline, procedural, and postprocedural inhospital outcomes were compared. The primary end point was the incidence of post-TAVR AR of any severity, assessed with a transthoracic echocardiogram, in the CV versus XT groups. A multivariate logistic regression analysis was completed to evaluate for correlates of the primary end point. The secondary end points included the change in severity of AR at 30-day and 1-year follow-up. A total of 223 consecutive patients (53% men, mean age 82 years) who had transfemoral TAVR with either a CV (n = 119) or XT (n = 104) were evaluated. The rates of post-TAVR AR in the groups were similar, and there was no evidence of more-than-moderate AR in either group. There were significant differences in the rates of intraprocedural balloon postdilation with the CV (17.1%) versus XT valve (5.8%; p = 0.009) and in the rates of intraprocedural implantation of a second valve-in-valve prosthesis with the CV (9.9%) versus XT valve (2.2%; p = 0.036). There were no significant differences in inhospital safety outcomes between the 2 groups. In conclusion, the incidence of post-TAVR AR is similar between the CV and the XT valve when performed by experienced operators using optimal intraprocedural strategies, as deemed appropriate, to mitigate the severity of AR. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Small sodium valve design and operating experience

    International Nuclear Information System (INIS)

    McGough, C.B.

    1974-01-01

    The United States Liquid Metal Fast Breeder Reactor program (LMFBR) includes an extensive program devoted to the development of small sodium valves. This program is now focused on the development and production of valves for the Fast Flux Test Facility (FFTF) now under construction near Richland, Washington. Other AEC support facilities, such as various test loops located at the Liquid Metal Engineering Center (LMEC), Los Angeles, California, and at the Hanford Engineering Development Laboratory (HEDL), Richland, Washington, also have significant requirements for small sodium valves, and valves similar in design to the FFTF valves are being supplied to these AEC laboratories for use in their critical test installations. A principal motivation for these valve programs, beyond the immediate need to provide high-reliability valves for FFTF and the support facilities, is the necessity to develop small valve technology for the Clinch River Breeder Reactor Plant (CRBRP). FFTF small sodium valve design and development experience will be directly applied to the CRBRP program. Various test programs have been, and are being, conducted to verify the performance and integrity of the FFTF valves, and to uncover any potential problems so that they can be corrected before the valves are placed in service in FFTF. The principal small sodium valve designs being utilized in current U.S. programs, the test and operational experience obtained to date on them, problems uncovered, and future development and testing efforts being planned are reviewed. The standards and requirements to which the valves are being designed and fabricated, the valve designs in current use, valve operators, test and operating experience, and future valve development plans are summarized. (U.S.)

  7. Experience with control valve cavitation problems and their solutions

    International Nuclear Information System (INIS)

    Ozol, J.

    1988-01-01

    Pressure reduction in control valves can induce cavitation, which has three effects on the control valve. Firstly, it modifies or changes the hydraulic performance of the control valve. Since control valves are designed for noncavitating conditions, the result is usually reduced stability of the control valve or, in extreme cavitating conditions known as supercavitation, the valve may limit the flow rate and thus be undersized. Secondly, cavitation can cause material damage to valve parts, trim, or valve body, or erodes downstream piping; consequently, the valve or piping leaks. Thirdly, cavitation causes noise and vibration, which may cause major damage or destruction to equipment such as valve positioners, actuators, pipe supports and sometimes to other downstream valves. The purpose of this paper is twofold: (1) It describes the I.S.A. valve sizing equations and how they relate to cavitation. (2) It describes experiences with these three problems, and discusses corrective actions and practical approaches to their solution. This paper discusses thirteen cavitation experiences

  8. A STUDY OF INDICATIONS, COMPLICATIONS OF PROSTHETIC VALVES AND PROGNOSIS AFTER TREATMENT OF STUCK VALVE

    Directory of Open Access Journals (Sweden)

    Y. V. Subba Reddy

    2017-03-01

    Full Text Available BACKGROUND Implantation of prosthetic cardiac valves to treat haemodynamically significant valvular diseases has become common; however, it is associated with complications. Thus, this study was intended to evaluate the indications for implantation of prosthetic valve and complications after its implantation and prognosis after treatment of one of its complication, i.e. stuck valve. MATERIALS AND METHODS This was a single-centered study wherein 50 patients who came to the emergency department with stuck valve were assessed. The 2D echocardiography was performed in all patients. Thrombolysis was done and the gradients were reassessed. Further response to treatment and development of complications before and after treatment were observed. RESULTS Of total patients, 60% were females. Mean age group was 30-40 yrs. Most of them were asymptomatic for 6 years and there was lack of compliance in 90% of patients. Most common indication for valve replacement was mitral stenosis (60% followed by mitral regurgitation (20%, aortic regurgitation and aortic stenosis (10% and combined mitral and tricuspid regurgitation (10%. Commonest valve was St. Jude (90%. Pannus was observed in 10% patients and thrombus was observed in 50% patients. Most patients had gradients 45/20 mmHg across mitral valve. In about 90% patients, gradients decreased after thrombolysis (12/5 mmHg. The complications after thrombolysis were hemiparesis (4%, death before thrombolysis (6% and death after thrombolysis (4%. CONCLUSION Considering these results, it can be concluded that prosthetic valves are seldom associated with some complications. Further, thrombolysis can be effective in patients with prosthetic valve thrombosis.

  9. Resurgery for recurrent heart valve diseases

    Directory of Open Access Journals (Sweden)

    Chong-lei REN

    2017-02-01

    Full Text Available Objective To summarize the experience with resurgery for recurrent valvular heart diseases. Methods From June 2004 to June 2015, 28 patients (15 males and 13 females with ages ranging from 44 to 67 years (55.6±6.5 years with recurrent heart valve disease underwent resurgery. The reasons for resurgery included perivalvular leakage (7 cases, bioprosthetic valve decline (6 cases in mitral valve and 3 in tricuspid valve, mechanical prostheses dysfunction (2cases, infective endocarditis after valve replacement (2 cases, restenosis of repaired native valve (1 case, and severe tricuspid insufficiency after left-side valve surgery (7 cases. Resurgery included mitral valve replacement in 18 patients and tricuspid valve replacement in 10. All the patients underwent third or fourth or even fifth cardiac surgery for valve replacement. Results There were 2 hospital deaths with a mortality of 7.1% (2/28. The main causes of early-stage deaths were low cardiac output syndrome. The main postoperative complications were respiratory failure in 3, low cardiac output syndrome in 2, reexploration for bleeding in 2 and serious infectious shock in 1. All the patients were found with the great improvement in heart function and the re-implanted prostheses worked well during follow-up. Conclusions Although resurgery for recurrent heart valve disease poses a continuing challenge to cardiac surgeon, it could be performed with the satisfactory results. The keys to a successful cardiac resurgery include appropriate operational timing, refined surgical technique and reasonable perioperative managements. DOI: 10.11855/j.issn.0577-7402.2017.01.11

  10. Proving test on the reliability for nuclear valves

    International Nuclear Information System (INIS)

    Kajiyama, Yasuo; Tashiro, Hisao; Uga, Takeo; Maeda, Shunichi.

    1986-01-01

    Since valves are the most common components, they could be the most frequent causes of troubles in nuclear power plants. This proving test, therefore, has an important meaning to examine and verify the reliability of various valves under simulating conditions of abnormal and transient operations of the nuclear power plant. The test was performed mainly for the various types and pressure ratings of valves which were used in the primary and secondary systems in BWR and PWR nuclear power plants and which had major operating or safety related functions in those nuclear power plants. The results of the proving test, confirmed for more than four years, showed relatively favourable performance of the tested valves. It is concluded that performances of valves including operability, seat sealing and structural integrity were proved under the thermal cycling, vibration and pipe reaction load conditions. Operating functions during and after accident such as loss of coolant accident were satisfactory. From these results, it was considered that the purpose of this proving test was satisfactorily fulfilled. Several data accumulated by the test would be useful to get better reliability if it was evaluated with the actually experienced data of valves in the nuclear power plants. (Nogami, K.)

  11. Strut fracture of Björk-Shiley convexo-concave valve in Japan--risk of small valve size--.

    Science.gov (United States)

    Watarida, S; Shiraishi, S; Nishi, T; Imura, M; Yamamoto, Y; Hirokawa, R; Fujita, M

    2001-08-01

    The Björk-Shiley convexo-concave (BSCC) prosthetic valve was introduced in 1979. Between 1979 and 1986, approximately 86,000 BSCC valves were implanted. By December 31, 1994, 564 complete strut fractures had been reported to the manufacture. We experienced a case of an outlet strut fracture and investigated the risk of BSCC prosthetic valve fractures in Japan. To investigate the risk factor of a strut fracture in Japan, we investigated published cases of strut fractures. Between 1979 and 1986, 2021 BSCC valves were implanted in Japan. By January 31, 2000, 11 complete strut fractures of 60-degree BSCC valves including our case had occurred. The patients were eight males and three females. The average age at valve replacement was 42.4+/-8.1 years, and nine of eleven (81.8%) were patients valve fractured was 47.7+/-6.4 years, and eight of eleven (72.7%) were patients valve were 27 mm (n=5) (45.5%), 29 mm (n=3) (27.2%), and 31 mm (n=3) (27.2%). Four patients died and seven patients survived. Although only 11 BSCC valve struts fractured and statistical analysis could not be performed, our findings suggest that the high risk group for a strut fracture in Japan is young male patients with a mitral valve, >= 27 mm in size with BSCC models manufactured before March 1982. When following-up patients with BSCC models manufactured before March 1982, the possibility of a strut fracture in all BSCC valve sizes should be kept in mind.

  12. CFD-Driven Valve Shape Optimization for Performance Improvement of a Micro Cross-Flow Turbine

    Directory of Open Access Journals (Sweden)

    Endashaw Tesfaye Woldemariam

    2018-01-01

    Full Text Available Turbines are critical parts in hydropower facilities, and the cross-flow turbine is one of the widely applied turbine designs in small- and micro-hydro facilities. Cross-flow turbines are relatively simple, flexible and less expensive, compared to other conventional hydro-turbines. However, the power generation efficiency of cross-flow turbines is not yet well optimized compared to conventional hydro-turbines. In this article, a Computational Fluid Dynamics (CFD-driven design optimization approach is applied to one of the critical parts of the turbine, the valve. The valve controls the fluid flow, as well as determines the velocity and pressure magnitudes of the fluid jet leaving the nozzle region in the turbine. The Non-Uniform Rational B-Spline (NURBS function is employed to generate construction points for the valve profile curve. Control points from the function that are highly sensitive to the output power are selected as optimization parameters, leading to the generation of construction points. Metamodel-assisted and metaheuristic optimization tools are used in the optimization. Optimized turbine designs from both optimization methods outperformed the original design with regard to performance of the turbine. Moreover, the metamodel-assisted optimization approach reduced the computational cost, compared to its counterpart.

  13. Mitral Valve Disease

    Science.gov (United States)

    ... for mitral valve replacement—mechanical valves (metal) or biological valves (tissue). The principal advantage of mechanical valves ... small risk of stroke due to blood clotting. Biological valves usually are made from animal tissue. Biological ...

  14. Factors Influencing Mortality after Bioprosthetic Valve Replacement; A Midterm Outcome

    OpenAIRE

    Hassan Javadzadegan; Amir Javadzadegan; Jafar Mehdizadeh Baghbani

    2013-01-01

    Introduction: Although valve repair is applied routinely nowadays, particularly for mitral regurgitation (MR) or tricuspid regurgitation (TR), valve replacement using prosthetic valves is also common especially in adults. Unfortunately the valve with ideal hemodynamic performance and long-term durability without increasing the risk of bleeding due to long-term anticoagulant therapy has not been introduced. Therefore, patients and physicians must choose either bioprosthetic or mechanical valve...

  15. High Reliability Cryogenic Piezoelectric Valve Actuator, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Cryogenic fluid valves are subject to harsh exposure and actuators to drive these valves require robust performance and high reliability. DSM's piezoelectric...

  16. Valve-sparing and valve-replacing techniques for aortic root replacement in patients with Marfan syndrome: Analysis of early outcome.

    Science.gov (United States)

    Volguina, Irina V; Miller, D Craig; LeMaire, Scott A; Palmero, Laura C; Wang, Xing Li; Connolly, Heidi M; Sundt, Thoralf M; Bavaria, Joseph E; Dietz, Harry C; Milewicz, Dianna M; Coselli, Joseph S

    2009-05-01

    A prospective, international registry study was initiated to provide contemporary comparative data on short-term clinical outcomes after aortic valve-sparing and aortic valve-replacing root operations in patients with Marfan syndrome. The purpose of this initial report is to describe the study design and to compare early outcomes in the first 151 enrolled patients. We assessed 30-day outcomes in 151 patients who met strict Ghent diagnostic criteria for Marfan syndrome and underwent aortic root replacement with either valve-replacing (n = 46) or valve-sparing techniques (n = 105) at one of 18 participating centers. In the valve replacement group, a mechanical composite valve graft was used in 39 (85%) patients and a bioprosthetic valve in 7 (15%). In the valve-sparing group, David V procedures were performed in 57 (54%) patients, David I in 38 (36%), David IV in 8 (8%), Florida sleeve in 1 (1%), and Yacoub remodeling in 1 (1%). No in-hospital or 30-day deaths occurred. Despite longer crossclamp and cardiopulmonary bypass times in the valve-sparing group, there were no significant between-group differences in postoperative complications. Thirty-day valve-related complications occurred in 2 (4%) patients undergoing valve replacement and in 3 (3%) undergoing valve-sparing procedures (P = .6). The analysis of early outcomes revealed that valve-sparing techniques were the most common approach to root replacement in patients with Marfan syndrome in these centers. The complexity of valve-sparing root replacement did not translate into any demonstrable adverse early outcomes. Subsequent analysis will compare the 3-year durability of these two surgical approaches.

  17. Experimental substantiation of the design of a prosthetic heart valve for «valve-in-valve» implantation

    Directory of Open Access Journals (Sweden)

    K. Yu. Klyshnikov

    2017-01-01

    Full Text Available The aim of the study was to perform a series of in vitro tests of a prototype of the developing heart valve prosthesis to evaluate its functional characteristics. Materials and methods. In this work we have used the frames and full prototypes of the prosthesis, consisting of a stent-like stainless steel support frame with mounted biological leaflets and cover. The authors evaluated the calculated and experimental forces necessary for the displacement of the sutureless implanted prosthesis using the test machine under uniaxial tension. The risk of defects and damages to the supporting framework as a result of implantation was evaluated by scanning electron microscopy. The hydrodynamic characteristics of the prosthesis were investigated under physiological conditions and «valvein-valve» implantation. Evaluation of the ergonomics and applicability of the proposed construction on the cadaver heart model of cattle was carried out. Results. As a result of the forces assessment, it was found that the force required to shear the prosthesis was 3.12 ± 0.37 N, while the calculated value was 1.7 N, which is significantly lower than the obtained value. The comparison of the images obtained with small and large magnifications demonstrated the absence of critical surface defects. Additional analysis under the super-large magnifications also did not reveal problem areas. During the hydrodynamic study, it was shown that the average transplant gradient increased slightly from 2.8–3.4 to 3.2–4.5 mm Hg for the initial prosthesis and the «valve-in-valve» complex, respectively. The decrease of the effective orifice area was 6–9% relative to the initial one. Evaluation of the implantation technique demonstrated the consistency of the approach: the use of the developed holder in combination with the balloon implantation system made it possible to position the prosthesis throughout the procedure. Conclusion. The series of tests demonstrates the consistency

  18. Comparison of 3D Echocardiogram-Derived 3D Printed Valve Models to Molded Models for Simulated Repair of Pediatric Atrioventricular Valves.

    Science.gov (United States)

    Scanlan, Adam B; Nguyen, Alex V; Ilina, Anna; Lasso, Andras; Cripe, Linnea; Jegatheeswaran, Anusha; Silvestro, Elizabeth; McGowan, Francis X; Mascio, Christopher E; Fuller, Stephanie; Spray, Thomas L; Cohen, Meryl S; Fichtinger, Gabor; Jolley, Matthew A

    2018-03-01

    Mastering the technical skills required to perform pediatric cardiac valve surgery is challenging in part due to limited opportunity for practice. Transformation of 3D echocardiographic (echo) images of congenitally abnormal heart valves to realistic physical models could allow patient-specific simulation of surgical valve repair. We compared materials, processes, and costs for 3D printing and molding of patient-specific models for visualization and surgical simulation of congenitally abnormal heart valves. Pediatric atrioventricular valves (mitral, tricuspid, and common atrioventricular valve) were modeled from transthoracic 3D echo images using semi-automated methods implemented as custom modules in 3D Slicer. Valve models were then both 3D printed in soft materials and molded in silicone using 3D printed "negative" molds. Using pre-defined assessment criteria, valve models were evaluated by congenital cardiac surgeons to determine suitability for simulation. Surgeon assessment indicated that the molded valves had superior material properties for the purposes of simulation compared to directly printed valves (p 3D echo-derived molded valves are a step toward realistic simulation of complex valve repairs but require more time and labor to create than directly printed models. Patient-specific simulation of valve repair in children using such models may be useful for surgical training and simulation of complex congenital cases.

  19. Simulation of proportional control of hydraulic actuator using digital hydraulic valves

    Science.gov (United States)

    Raghuraman, D. R. S.; Senthil Kumar, S.; Kalaiarasan, G.

    2017-11-01

    Fluid power systems using oil hydraulics in earth moving and construction equipment have been using proportional and servo control valves for a long time to achieve precise and accurate position control backed by system performance. Such valves are having feedback control in them and exhibit good response, sensitivity and fine control of the actuators. Servo valves and proportional valves are possessing less hysteresis when compared to on-off type valves, but when the servo valve spools get stuck in one position, a high frequency called as jitter is employed to bring the spool back, whereas in on-off type valves it requires lesser technology to retract the spool. Hence on-off type valves are used in a technology known as digital valve technology, which caters to precise control on slow moving loads with fast switching times and with good flow and pressure control mimicking the performance of an equivalent “proportional valve” or “servo valve”.

  20. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    Science.gov (United States)

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  1. From Mouth-to-Mouth to Bag-Valve-Mask Ventilation: Evolution and Characteristics of Actual Devices—A Review of the Literature

    Directory of Open Access Journals (Sweden)

    Abdo Khoury

    2014-01-01

    Full Text Available Manual ventilation is a vital procedure, which remains difficult to achieve for patients who require ventilatory support. It has to be performed by experienced healthcare providers that are regularly trained for the use of bag-valve-mask (BVM in emergency situations. We will give in this paper, a historical view on manual ventilation’s evolution throughout the last decades and describe the technical characteristics, advantages, and hazards of the main devices currently found in the market. Artificial ventilation has developed progressively and research is still going on to improve the actual devices used. Throughout the past years, a brand-new generation of ventilators was developed, but little was done for manual ventilation. Many adverse outcomes due to faulty valve or misassembly were reported in the literature, as well as some difficulties to ensure efficient insufflation according to usual respiratory parameters. These serious incidents underline the importance of BVM system routine check and especially the unidirectional valve reassembly after sterilization, by only experienced and trained personnel. Single use built-in devices may prevent disassembly problems and are safer than the reusable ones. Through new devices and technical improvements, the safety of BVM might be increased.

  2. Mechanical performance of pyrolytic carbon in prosthetic heart valve applications.

    Science.gov (United States)

    Cao, H

    1996-06-01

    An experimental procedure has been developed for rigorous characterization of the fracture resistance and fatigue crack extension in pyrolytic carbon for prosthetic heart valve application. Experiments were conducted under sustained and cyclic loading in a simulated biological environment using Carbomedics Pyrolite carbon. While the material was shown to have modest fracture toughness, it exhibited excellent resistance to subcritical crack growth. The crack growth kinetics in pyrolytic carbon were formulated using a phenomenological description. A fatigue threshold was observed below which the crack growth rate diminishes. A damage tolerance concept based on fracture mechanics was used to develop an engineering design approach for mechanical heart valve prostheses. In particular, a new quantity, referred to as the safe-life index, was introduced to assess the design adequacy against subcritical crack growth in brittle materials. In addition, a weakest-link statistical description of the fracture strength is provided and used in the design of component proof-tests. It is shown that the structural reliability of mechanical heart valves can be assured by combining effective flaw detection and manufacturing quality control with adequate damage tolerance design.

  3. Outlet strut fracture of Björk-Shiley convexo-concave valves: can valve-manufacturing characteristics explain the risk?

    Science.gov (United States)

    Omar, R Z; Morton, L S; Beirne, M; Blot, W J; Lawford, P V; Hose, R; Taylor, K M

    2001-06-01

    Björk-Shiley 60 degrees convexo-concave prosthetic heart valves (Shiley, Inc, Irvine, Calif, a subsidiary of Pfizer, Inc) continue to be a concern for approximately 35,000 nonexplanted patients worldwide, with approximately 600 events reported to the manufacturer to date. Fractures of the outlet struts of the valves began to appear in the early 1980s and have continued to the present, but their causes are only partially understood. A matched case-control study was conducted evaluating manufacturing records for 52 valves with outlet strut fractures and 248 control subjects matched for age at implantation, valve size, and valve position. In addition to the risk factors recognized as determinants of outlet strut fracture, the United Kingdom case-control study has observed 7- to 9-fold increased risk with performance of multiple hook deflection tests. This test was performed more than once, usually after rework on the valve. Six valves in this study underwent multiple hook deflection tests, of which 4 experienced an outlet strut fracture. Cracks and further rework were noted for these valves. Significant associations were also observed between outlet strut fracture and disc-to-strut gap measurements taken before the attachment of the sewing ring. It is our view that a combination of factors related to valve design, manufacturing process, and patient characteristics are responsible for outlet strut fractures of Björk-Shiley convexo-concave valves. Multiple hook deflection tests have emerged as a potential new risk factor for outlet strut fracture in both The Netherlands and the United Kingdom. This factor appears to be correlated with the presence of other abnormalities. A further study is needed to investigate the factors correlated with multiple hook deflection tests. On confirmation of risk, the presence of multiple hook deflection tests may be added to equations, quantifying the risk of outlet strut fracture for comparison against risk of mortality and serious

  4. Tight valve

    International Nuclear Information System (INIS)

    Guedj, F.

    1987-01-01

    This sealed valve is made with a valve seat, an axial valve with a rod fixed to its upper end, a thick bell surrounding the rod and welded by a thin join on the valve casing, a threated ring screwed onto the upper end of the rod and a magnet or electromagnet rotating the ring outside the bell [fr

  5. New piezo driven gas inlet valve for fusion experiments

    International Nuclear Information System (INIS)

    Usselmann, E.; Hemmerich, J.L.; How, J.; Holland, D.; Orchard, J.; Winkel, T.; Schargitz, U.; Pocheim, N.

    1989-01-01

    The gas inlet valves used at the JET experiment are described and their performances are discussed. A new gas-valve development suitable to replace the existing valves at JET and for future use in large fusion experiments is presented. The new valve is equipped with a piezo-electric translator and has a dosing range of 0-800 mbarls -1 for D 2 . The operating mode of the valve is fail-safe closed with a leak-rate of ≤ 10 -9 mbarls -1 . The design, the test results and throughput values in dependence of filling pressure and control voltage are presented and experiences with the prototype valve as a new gas inlet valve for the JET operation are described

  6. CMM Interim Check (U)

    Energy Technology Data Exchange (ETDEWEB)

    Montano, Joshua Daniel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-03-23

    Coordinate Measuring Machines (CMM) are widely used in industry, throughout the Nuclear Weapons Complex and at Los Alamos National Laboratory (LANL) to verify part conformance to design definition. Calibration cycles for CMMs at LANL are predominantly one year in length. Unfortunately, several nonconformance reports have been generated to document the discovery of a certified machine found out of tolerance during a calibration closeout. In an effort to reduce risk to product quality two solutions were proposed – shorten the calibration cycle which could be costly, or perform an interim check to monitor the machine’s performance between cycles. The CMM interim check discussed makes use of Renishaw’s Machine Checking Gauge. This off-the-shelf product simulates a large sphere within a CMM’s measurement volume and allows for error estimation. Data was gathered, analyzed, and simulated from seven machines in seventeen different configurations to create statistical process control run charts for on-the-floor monitoring.

  7. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI). ...

  8. Use of expert judgment in the development and evaluation of risk-based inservice testing strategies for pumps and valves

    International Nuclear Information System (INIS)

    McAllister, W.J.; Perdue, R.K.; Balkey, K.R.; Closky, N.B.

    1996-01-01

    This paper describes a rigorous approach for quantitatively evaluating inservice testing effectiveness that evolved from two pilot plant studies. These studies prototyped methodologies for designing and selecting inservice testing (IST) strategies in a manner structured to insure that the targeted components will perform their required safety functions while minimizing life cycle inservice testing costs. The paper concentrates on the use of expert judgment in developing test effectiveness measures that move risk-based methods beyond ranking to optimization of plant IST programs. Selected results for check valves and pumps are shown to illustrate the practical significance of the approach

  9. Use of expert judgment in the development and evaluation of risk-based inservice testing strategies for pumps and valves

    Energy Technology Data Exchange (ETDEWEB)

    McAllister, W.J.; Perdue, R.K.; Balkey, K.R.; Closky, N.B. [and others

    1996-12-01

    This paper describes a rigorous approach for quantitatively evaluating inservice testing effectiveness that evolved from two pilot plant studies. These studies prototyped methodologies for designing and selecting inservice testing (IST) strategies in a manner structured to insure that the targeted components will perform their required safety functions while minimizing life cycle inservice testing costs. The paper concentrates on the use of expert judgment in developing test effectiveness measures that move risk-based methods beyond ranking to optimization of plant IST programs. Selected results for check valves and pumps are shown to illustrate the practical significance of the approach.

  10. ADAM®/SIPLUG®: An innovative valve monitoring system

    International Nuclear Information System (INIS)

    Muñoz, L.; Krell, M.

    2012-01-01

    Optimized maintenance strategies are a key aspect for safe and undisturbed plant operation. Innovative valve service solutions, e.g. valve diagnostics can support this in an efficient way. The ADAM®/SIPLUG® valve monitoring system allows full online monitoring of valves and actuators with automatic evaluation and assessment. Especially for safety-related and operation-related valves this provides valuable information on components condition to ensure proper function and contribute to optimization of maintenance strategies as well as effective maintenance performance. The new SIPLUG®-4 modules are the evolutionary solution for valve diagnosis at the Motor Control Center (MCC). As the SIPLUG®-4 can be installed directly in the MCC outgoing actuator power cable it allows an easy installation in existing switchgear cabinets. Measurement at MCC means also zero effort for performance of diagnostics reducing the number of on-site activities. This results in decrease of maintenance costs and dose rates for deployed personnel. The ADAM® evaluation software and database was developed in parallel with the hardware. It provides automatic analysis of the monitoring results using the limit values specified for the valves. The measured data can be transmitted via the power plant’s local area network to the ADAM® data server, if the SIPLUG® online hardware is installed. With the mobile solution, the data can be transmitted via serial or USB interface to a PC or notebook. With this solution all measurement information will be available immediately in the offices of plant engineers. Also, with SIPLUG® online all operations of valves can be automatically recorded. More than 25 years of experience in various plants worldwide show that the application of ADAM®/SIPLUG® valve diagnostics solution leads to increased plant safety and availability. Some of the references for ADAM®/SIPLUG® are Germany, Switzerland, Brazil, Spain and Eastern Europe. (author)

  11. A novel implantable glaucoma valve using ferrofluid.

    Directory of Open Access Journals (Sweden)

    Eleftherios I Paschalis

    Full Text Available PURPOSE: To present a novel design of an implantable glaucoma valve based on ferrofluidic nanoparticles and to compare it with a well-established FDA approved valve. SETTING: Massachusetts Eye & Ear Infirmary, Boston, USA. METHODS: A glaucoma valve was designed using soft lithography techniques utilizing a water-immiscible magnetic fluid (ferrofluid as a pressure-sensitive barrier to aqueous flow. Two rare earth micro magnets were used to calibrate the opening and closing pressure. In-vitro flow measurements were performed to characterize the valve and to compare it to Ahmed™ glaucoma valve. The reliability and predictability of the new valve was verified by pressure/flow measurements over a period of three months and X-ray diffraction (XRD analysis over a period of eight weeks. In vivo assessment was performed in three rabbits. RESULTS: In the in vitro experiments, the opening and closing pressures of the valve were 10 and 7 mmHg, respectively. The measured flow/pressure response was linearly proportional and reproducible over a period of three months (1.8 µl/min at 12 mmHg; 4.3 µl/min at 16 mmHg; 7.6 µl/min at 21 mmHg. X-ray diffraction analysis did not show oxidization of the ferrofluid when exposed to water or air. Preliminary in vivo results suggest that the valve is biocompatible and can control the intraocular pressure in rabbits. CONCLUSIONS: The proposed valve utilizes ferrofluid as passive, tunable constriction element to provide highly predictable opening and closing pressures while maintaining ocular tone. The ferrofluid maintained its magnetic properties in the aqueous environment and provided linear flow to pressure response. Our in-vitro tests showed reliable and reproducible results over a study period of three months. Preliminary in-vivo results were very promising and currently more thorough investigation of this device is underway.

  12. Evaluating All-Metal Valves for Use in a Tritium Environment

    Energy Technology Data Exchange (ETDEWEB)

    Houk, L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Payton, A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-09-28

    In the tritium gas processing system, it is desired to minimize polymer components due to their degradation from tritium exposure (beta decay). One source of polymers in the tritium process is valve components. A vendor has been identified that manufactures a valve that is marketed as being made from all-metal construction. This manufacturer, Ham-Let Group, manufactures a diaphragm valve (3LE series) that claims to be made entirely of metal. SRNL procured twelve (12) Ham-Let diaphragm valves for characterization and evaluation. The characterization tests include identification of the maximum pressure of these valves by performing pressure and burst tests. Leak tests were performed to ensure the valves do not exceed the acceptable leak rate for tritium service. These valves were then cycled in a nitrogen gas and/or vacuum environment to ensure they would be durable in a process environment. They were subsequently leak tested per ASTM protocol to ensure that the valves maintained their leak tight integrity. A detailed material analysis was also conducted to determine hydrogen and tritium compatibility.

  13. 3-D analysis of reactor loop isolation valves

    International Nuclear Information System (INIS)

    Dietrich, D.E.

    1975-01-01

    A full three-dimensional analysis for the design and operational loading conditions was performed on a 29 inch loop isolation valve using the Westinghouse finite element computer code. The 3-D analysis was employed for the valve design in place of utilizing the standard ASME valve design criteria. The valve design employs the design by analysis concept allowed for nuclear class valve. The valve design was evaluated for a set of independent load including pipe reactions and internal pressure. The design pipe reaction loads were based upon maximum fiber pipe stresses at yield for the bending moments, pipe membrane stresses at half yield for the axial load, and pipe maximum shear stress at half yield for the torsional moment. The valve design pressure was the system loop design pressure. The operating and accident condition evaluation included pipe reactions, extended structure forces, system pressure, and system thermal transients. The valve was analyzed for the normal operating, upset, emergency, and faulted loading conditions. These operating and accident conditions used various specified combinations of the supplied generic system pressure, deadweight, thermal, seismic, and LOCA pipe load components. The generic pipe loads are the worst possible postulated loads for any system design. These generic pipe load components were supplied as maximums and minimums so a simplified nozzle analysis was performed to determine the worst case combination for each loading condition. The valve design was shown to meet the design, operating, and accident condition requirements of the ASME code. The design by analysis concept for nuclear class 1 valves gave a significant reduction in required minimum wall thickness, 3.75 inches vs. 5.4 inches. These translate into significant material savings

  14. Function analysis of steam isolation valves

    International Nuclear Information System (INIS)

    Persson, R.; Sjoeberg, A.; Aakesson, H.; Kilpi, K.; Noro, H.; Siikonen, T.; Wallen, G.

    1981-01-01

    Function analysis of system-medium-operated steam isolation valves has been the objective of the Swedish-Finnish IVLS project, the results of which are presented in this report. Theoretical models were to be verified against available experimental data, to some extent from the HDR blowdown experiments, which are part of a German reactor safety program. Finnish hydraulic measurements on a valve model (scale 1:2.15) have been performed to give complementary data. The analysis work has covered the thermal-hydraulic behaviour of steam isolation valves as well as phenomena related to structural mechanics. (Auth.)

  15. Evolving Concepts in Transcatheter Aortic Valve Implantation

    NARCIS (Netherlands)

    Nijhoff, F.

    2015-01-01

    Part I of the present thesis is dedicated to implantation technique and the clinical performance of new valve prostheses. A satisfactory TAVI result not solely depends on patient characteristics, but also relies on proper valve positioning and final placement. Moreover, prosthetic design is

  16. An improved gate valve for critical applications in nuclear power plants

    International Nuclear Information System (INIS)

    Kalsi, M.S.; Alvarez, P.D.; Wang, J.K.; Somagyi, D.

    1996-01-01

    U.S. Nuclear Regulatory Commission Generic Letters 89-10 for motor-operated valves (MOVs) and 95-07 for all power-operated valves document in detail the problems related to the performance of the safety-related valves in nuclear power plants. The problems relate to lack of reliable operation under design basis conditions including higher than anticipated stem thrust, unpredictable valve behavior, damage to the valve internals under blowdown/high flow conditions, significant degradation of performance when cycled under AP and flow, thermal binding, and pressure locking. This paper describes an improved motor-operated flexible wedge gate valve design, the GE Sentinel Valve, which is the outcome of a comprehensive and systematic development effort undertaken to resolve the issues identified in the NRC Generic Letters 89-10 and 95-07. The new design provides a reliable, long-term, low maintenance cost solution to the nuclear power industry. One of the key features incorporated in the disc permits the disc flexibility to be varied independently of the disc thickness (pressure boundary) dictated by the ASME Section III Pressure Vessel ampersand Piping Code stress criteria. This feature allows the desired flexibility to be incorporated in the disc, thus eliminating thermal binding problems. A matrix of analyses was performed using finite element and computational fluid dynamics approaches to optimize design for stresses, flexibility, leak-tightness, fluid flow, and thermal effects. The design of the entire product line was based upon a consistent set of analyses and design rules which permit scaling to different valve sizes and pressure classes within the product line. The valve meets all of the ASME Section III Code design criteria and the N-Stamp requirements. The performance of the valve was validated by performing extensive separate effects and plant in-situ tests. This paper summarizes the key design features, analyses, and test results

  17. An improved gate valve for critical applications in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Kalsi, M.S.; Alvarez, P.D.; Wang, J.K.; Somagyi, D. [Kalsi Engineering, Inc., Sugar Land, TX (United States)] [and others

    1996-12-01

    U.S. Nuclear Regulatory Commission Generic Letters 89-10 for motor-operated valves (MOVs) and 95-07 for all power-operated valves document in detail the problems related to the performance of the safety-related valves in nuclear power plants. The problems relate to lack of reliable operation under design basis conditions including higher than anticipated stem thrust, unpredictable valve behavior, damage to the valve internals under blowdown/high flow conditions, significant degradation of performance when cycled under AP and flow, thermal binding, and pressure locking. This paper describes an improved motor-operated flexible wedge gate valve design, the GE Sentinel Valve, which is the outcome of a comprehensive and systematic development effort undertaken to resolve the issues identified in the NRC Generic Letters 89-10 and 95-07. The new design provides a reliable, long-term, low maintenance cost solution to the nuclear power industry. One of the key features incorporated in the disc permits the disc flexibility to be varied independently of the disc thickness (pressure boundary) dictated by the ASME Section III Pressure Vessel & Piping Code stress criteria. This feature allows the desired flexibility to be incorporated in the disc, thus eliminating thermal binding problems. A matrix of analyses was performed using finite element and computational fluid dynamics approaches to optimize design for stresses, flexibility, leak-tightness, fluid flow, and thermal effects. The design of the entire product line was based upon a consistent set of analyses and design rules which permit scaling to different valve sizes and pressure classes within the product line. The valve meets all of the ASME Section III Code design criteria and the N-Stamp requirements. The performance of the valve was validated by performing extensive separate effects and plant in-situ tests. This paper summarizes the key design features, analyses, and test results.

  18. Defining indicators to motorize block valves aiming to reduce potential leakage applied to OSBRA pipeline

    Energy Technology Data Exchange (ETDEWEB)

    Pires, L.F.G. [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio), RJ (Brazil); Sousa, A.G.; Castro, N.C.; Spagnolo, R. [Petrobras Transporte S.A. (TRANSPETRO), Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The discussion about motorizing block valves is a constant point being brought up when it is intended to control or reduce the amount of liquid leaking in the event of a pipe rupture. During the pipeline's project stage the installation of blocking valves along the pipeline must be taken into consideration to meet the operation and maintenance requirements as well as to reduce the potential amounts of volume being leaked. In existing pipelines, the main concern is the definition of which valves are candidates to be motorized. In both situations criteria should be established to define this choice. A math algorithm was developed to define the potential leakage due to gravity along the pipeline profile where the influence of a valve over another is verified, as well as the contribution of the check valves existing in the pipeline. The present work defines a parameter based on the extension protected by the valve and the reduction of the potential leakage. This parameter is then fed to a worksheet where the efficiency indicators are calculated to each valve eligible to be motorized. It also takes into consideration factors relative to the valve location, such as the environmental sensitivity, risk assessment, social diagnosis and device's proximity to contingency resources. Finally, after considering all the above aspects, it's possible to come up with a final classification, recommending specific valves to be prioritized on an eventual process of motorization adequacies. This methodology was applied, experimentally on a pipe segment of TRANSPETRO's Sao Paulo-Brasilia pipeline - OSBRA , where it proved to be an important technological and management tool. (author)

  19. Prototype bellows sealed nuclear valve development -reliability through testing

    International Nuclear Information System (INIS)

    Dixon, D.F.; Abbas, M.

    1978-01-01

    To assist in appraising bellows sealed valve performance, 10 tests were done on a ''1 in.'' prototype bellows sealed valve design. The tests simulated primary heat transport (PHT) system conditions for a 600 MWe CANDU-PHW. The design approach was to have all valve components outlast the bellows in endurance tests; this was achieved. The valve design meets the Atomic Energy of Canada Limited specification. For comparison, bellows fatigue failure data were fitted to both log-normal and Weibull distributions. A numerical example shows how to select valve stroke amplitude on the basis of valve flow requirement and the minimum acceptable fatigue life. (author)

  20. Are anticoagulant independent mechanical valves within reach-fast prototype fabrication and in vitro testing of innovative bi-leaflet valve models.

    Science.gov (United States)

    Scotten, Lawrence N; Siegel, Rolland

    2015-08-01

    Exploration for causes of prosthetic valve thrombogenicity has frequently focused on forward or post-closure flow detail. In prior laboratory studies, we uncovered high amplitude flow velocities of short duration close to valve closure implying potential for substantial shear stress with subsequent initiation of blood coagulation pathways. This may be relevant to widely accepted clinical disparity between mechanical and tissue valves vis-à-vis thrombogenicity. With a series of prototype bi-leaflet mechanical valves, we attempt reduction of closure related velocities with the objective of identifying a prototype valve with thrombogenic potential similar to our tissue valve control. This iterative design approach may find application in preclinical assessment of valves for anticoagulation independence. Tested valves included: prototype mechanical bi-leaflet BVs (n=56), controls (n=2) and patented early prototype mechanicals (n=2) from other investigators. Pulsatile and quasi-steady flow systems were used for testing. Projected dynamic valve area (PDVA) was measured using previously described novel technology. Flow velocity over the open and closing periods was determined by volumetric flow rate/PDVA. For the closed valve interval, use was made of data obtained from quasi-steady back pressure/flow tests. Performance was ranked by a proposed thrombogenicity potential index (TPI) relative to tissue and mechanical control valves. Optimization of the prototype valve designs lead to a 3-D printed model (BV3D). For the mitral/aortic site, BV3D has lower TPI (1.10/1.47) relative to the control mechanical valve (3.44/3.93) and similar to the control tissue valve (ideal TPI ≤1.0). Using unique technology, rapid prototyping and thrombogenicity ranking, optimization of experimental valves for reduced thrombogenic potential was expedited and simplified. Innovative mechanical valve configurations were identified that merit consideration for further development which may bring

  1. Investigation of a rotary valving system with variable valve timing for internal combustion engines

    Science.gov (United States)

    Cross, Paul C.; Hansen, Craig N.

    1994-11-01

    The objective of the program was to provide a functional demonstration of the Hansen Rotary Valving System with Variable Valve Timing (HRVS/VVT), capable of throttleless inlet charge control, as an alternative to conventional poppet-valves for use in spark ignited internal combustion engines. The goal of this new technology is to secure benefits in fuel economy, broadened torque band, vibration reduction, and overhaul accessibility. Additionally, use of the variable valve timing capability to vary the effective compression ratio is expected to improve multifuel tolerance and efficiency. Efforts directed at the design of HRVS components proved to be far more extensive than had been anticipated, ultimately requiring that proof-trial design/development work be performed. Although both time and funds were exhausted before optical or ion-probe types of in-cylinder investigation could be undertaken, a great deal of laboratory data was acquired during the course of the design/development work. This laboratory data is the basis for the information presented in this final report.

  2. 40 CFR 86.327-79 - Quench checks; NOX analyzer.

    Science.gov (United States)

    2010-07-01

    ... any flow rate into the reaction chamber. This includes, but is not limited to, sample capillary, ozone... Quench checks; NOX analyzer. (a) Perform the reaction chamber quench check for each model of high vacuum reaction chamber analyzer prior to initial use. (b) Perform the reaction chamber quench check for each new...

  3. Multidetector computed tomography sizing of bioprosthetic valves: guidelines for measurement and implications for valve-in-valve therapies

    International Nuclear Information System (INIS)

    Rajani, R.; Attia, R.; Condemi, F.; Webb, J.; Woodburn, P.; Hodson, D.; Nair, A.; Preston, R.; Razavi, R.; Bapat, V.N.

    2016-01-01

    Aim: To describe a technique for bioprosthetic multidetector computed tomography (MDCT) sizing and to compare MDCT-derived values against manufacturer-provided sizing. Materials and methods: Fourteen bioprosthetic stented valves commonly used in the aortic valve position were evaluated using a Philips 256 MDCT system. All valves were scanned using a dedicated cardiac CT protocol with a four-channel electrocardiography (ECG) simulator. Measurements were made of major and minor axes and the area and perimeter of the internal stent using varying reconstruction kernels and window settings. Measurements derived from MDCT (MDCT ID) were compared against the stent internal diameter (Stent ID) as provided by the valve manufacturer and the True ID (Stent ID + insertion of leaflets). All data were collected and analysed using SPSS for Mac (version 21). Results: The mean difference between the MDCT ID and Stent ID was 0.6±1.9 mm (r=0.649, p=0.012) and between MDCT ID and True ID 2.1±2 mm (r=0.71, p=0.005). There was no difference in the major (p=0.90), minor (p=0.87), area (p=0.92), or perimeter (p=0.92) measurements when sharp, standard, and detailed stent kernels were used. Similarly, the measurements remained consistent across differing windowing levels. Conclusion: Bioprosthetic stented valves may be reliably sized using MDCT in patients requiring valve-in-valve (VIV) interventions where the valve type and size are unknown. In these cases, clinicians should be aware that MDCT has a tendency to overestimate the True ID size. - Highlights: • Cardiac CT is likely to be ideally suited for bioprosthetic aortic valve sizing for valve in valve procedures. • We compared MDCT sizing for 14 varying bioprosthetic aortic valves across varying window settings and reconstruction kernels. • We provide “normal” MDCT sizing for varying valves and show their relationship to surgical sizing. • Bioprosthetic valves may be reliably sized by MDCT but require adjustment owing to

  4. Transcatheter pulmonary valve replacement by hybrid approach using a novel polymeric prosthetic heart valve: proof of concept in sheep.

    Directory of Open Access Journals (Sweden)

    Ben Zhang

    Full Text Available Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach.We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve, weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically.Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen macroscopically

  5. CATHARE2 V1.4 capability to simulate the performance of isolation condenser systems with thermal valve

    International Nuclear Information System (INIS)

    Meloni, P.

    2001-01-01

    ENEA (Italy) in co-operation with CEA (France) has carried out an R and D activity aimed at increasing the reliability of Decay Heat Removal (DHR) passive systems that implement in-pool heat exchangers. The main outcome reached was the definition of a device, called Thermal Valve (TV), able to avoid the installation of mechanical valve on the primary circuit, thus reducing thermalmechanical constrains and thermal-hydraulic instabilities. This paper presents a preliminary assessment performed with CATHARE of this innovative device. In the first part the code capability to simulate in-pool heat exchangers is verified against experimental data of the PANDA facility, that are available within the frame of the ISP 42. In the second part a CATHARE calculation showing the performances of the PANDA passive condenser with TV (start-up and shutdown) is described.(author)

  6. Magnetostatic Analysis of a Pinch Mode Magnetorheological Valve

    Directory of Open Access Journals (Sweden)

    Gołdasz Janusz

    2017-09-01

    Full Text Available The study deals with the pinch mode of magnetorheological (MR fluids’ operation and its application in MR valves. By applying the principle in MR valves a highly non-uniform magnetic field can be generated in flow channels in such a way to solidify the portion of the material that is the nearest to the flow channel’s walls. This is in contrary to well-known MR flow mode valves. The authors investigate a basic pinch mode valve in several fundamental configurations, and then examine their magnetic circuits through magnetostatic finite-element (FE analysis. Flux density contour maps are revealed and basic performance figures calculated and analysed. The FE analysis results yield confidence in that the performance of MR pinch mode devices can be effectively controlled through electromagnetic means.

  7. Operating experience and design criteria of sodium valves

    International Nuclear Information System (INIS)

    Markford, D.

    1974-01-01

    The information presented refers to sodium valve development for KNK and SNR-300 as well as for sodium test facilities on the INTERATOM site at Bensberg. Well in advance of KNK-I a number of sodium test facilities have been operated containing small and medium size valves of different design and manufacturer. The more stringent requirements for long range safe and reliable operation in KNK-I put forth a development program for the main primary and secondary circuit sodium valves. Operational experience gave rise to modification of the stem seal arrangement mainly, so KNK-II (which is the fast core for KNK reactor) will be run with modified sodium valves. Main pipe diameters in SNR-300 are in the range of 600 mm. Valve designs with rising shafts would require excessive space in the primary circuit cavities, therefore efforts have been directed towards introduction of different type valves. Due to the requirements of after-heat-removal a valve type with control capability had to be chosen. A special design of butterfly valves was selected for the primary and secondary circuits of SNR-300. The development and tests performed with this type of valve are described. In the field of small sodium valves, tests with a 50 mm diameter freeze-seal valve are reported, and the current status of bellows-seal-valves to be inserted into SNR-300 is discussed. (U.S.)

  8. Variable valve trains for internal combustion engines to control the valve height and the opening time; Variable Ventiltriebe fuer Verbrennungsmotoren zur Veraenderung von Ventilhub und Oeffnungsdauer

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Gunther [ThyssenKrupp Presta TecCenter AG, Eschen (Liechtenstein). R and D Projects

    2009-11-15

    The PDVC (Presta Delta Valve Control) continuously variable valve lift system is a mechanical system of valve control for achieving optimum performance and resulting in improved fuel consumption and reduced emissions across the entire operating range of the combustion engine. The continuous variability allows for engine load control by adjusting the valve height and therefore can also be used to replace the traditional throttle. The advantages are lower fuel consumption, reduction in emissions, quicker engine response, higher torque during the low speed range as well as more stable idling. The PSVC (Presta Shiftable Valve Control) is a 3 step shiftable valve lift system that offers the possibility to achieve a major part of these performance and associated consumption benefits with a simpler and therefore more cost-effective system. (orig.)

  9. Safety and relief valves in light water reactors

    International Nuclear Information System (INIS)

    Singh, A.

    1985-12-01

    Information is presented to: provide an introduction to and descriptions of various types of safety and relief valves in both PWR and BWR plants; describe anticipated operating conditions for these valves; describe the test facilities, procedures, and major results for both types of valves; present an extensive discussion of modeling and analysis of safety and relief valve performance, including the prediction of flow capacity and stability during operation; deal with the analyses related to the prediction of thermal-hydraulic loads on discharge piping and comparison against test data; discuss results of small-scale valve tests and flow visualization studies through transparent valve models; and describe an EPRI study for optimizing a typical PWR over-pressure protection system to enhance the availability and reliability of plant operation and thus reduce operation costs

  10. Implante valve-in-valve transcateter em posição aórtica: uma mudança de seleção? Transcatheter aortic valve-in-valve implantation: a selection change?

    Directory of Open Access Journals (Sweden)

    Diego Felipe Gaia

    2012-09-01

    . Minimally invasive transcatheter aortic "valve-in-valve" implant appears to be an alternative, reducing morbidity and mortality. The objective is to evaluate aortic valve-in-valve procedure using Braile Inovare prosthesis. METHODS: The Braile Inovare prosthesis, transcatheter, expandable balloon, was used in 14 cases. Average EuroSCORE was 42.9%. All patients had double aortic bioprosthesis dysfunction. Procedures were performed in a surgical hybrid environment under echocardiographic and fluoroscopic guidance. Using left minithoracotomy prostheses were implanted through the ventricular apex under high-frequency ventricular pacing. Serial clinical and echocardiographic controls were performed. Follow-up ranged 1-30 months. RESULTS: Correct prosthetic deployment was obtained in all cases. There was no conversion. There was no operative mortality. The 30-day mortality was 14.3% (two cases. Ejection fraction increased significantly after the 7th postoperative day. Aortic gradient significantly reduced. The residual aortic regurgitation was not present. There were no vascular complications or complete atrioventricular block. CONCLUSION: The transcatheter "valve-in-valve" procedure for bioprosthesis dysfunction is safe with low morbidity. This possibility may change prosthesis choice during the first aortic valve replacement, favoring bioprostheses.

  11. Application of RELAP5/MOD3.3 to Calculate Thermal Hydraulic Behavior of the Pressurizer Safety Valve Performance Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Hyun; Kim, Young Ae; Oh, Seung Jong; Park, Jong Woon [Korea Hydro and Nuclear Power Co., Ltd., Daejeon (Korea, Republic of)

    2007-10-15

    The increase of the acceptance tolerance of Pressurizer Safety Valve (PSV) test is vital for the safe operation of nuclear power plants because the frequent tests may make the valves decrepit and become a cause of leak. Recently, Korea Hydro and Nuclear Power Company (KHNP) is building a PSV performance test facility to provide the technical background data for the relaxation of the acceptance tolerance of PSV including the valve pop-up characteristics and the loop seal dynamics (if the plant has the loop seal in the upstream of PSV). The discharge piping and supports must be designed to withstand severe transient hydrodynamic loads when the safety valve actuates. The evaluation of hydrodynamic loads is a two-step process: first the thermal hydraulic behavior in the piping must be defined, and then the hydrodynamic loads are calculated from the thermal hydraulic parameters such as pressure and mass flow. The hydrodynamic loads are used as input to the structural analysis.

  12. Automated electric valve for electrokinetic separation in a networked microfluidic chip.

    Science.gov (United States)

    Cui, Huanchun; Huang, Zheng; Dutta, Prashanta; Ivory, Cornelius F

    2007-02-15

    This paper describes an automated electric valve system designed to reduce dispersion and sample loss into a side channel when an electrokinetically mobilized concentration zone passes a T-junction in a networked microfluidic chip. One way to reduce dispersion is to control current streamlines since charged species are driven along them in the absence of electroosmotic flow. Computer simulations demonstrate that dispersion and sample loss can be reduced by applying a constant additional electric field in the side channel to straighten current streamlines in linear electrokinetic flow (zone electrophoresis). This additional electric field was provided by a pair of platinum microelectrodes integrated into the chip in the vicinity of the T-junction. Both simulations and experiments of this electric valve with constant valve voltages were shown to provide unsatisfactory valve performance during nonlinear electrophoresis (isotachophoresis). On the basis of these results, however, an automated electric valve system was developed with improved valve performance. Experiments conducted with this system showed decreased dispersion and increased reproducibility as protein zones isotachophoretically passed the T-junction. Simulations of the automated electric valve offer further support that the desired shape of current streamlines was maintained at the T-junction during isotachophoresis. Valve performance was evaluated at different valve currents based on statistical variance due to dispersion. With the automated control system, two integrated microelectrodes provide an effective way to manipulate current streamlines, thus acting as an electric valve for charged species in electrokinetic separations.

  13. Study on the selection method of feed water heater safety valves in nuclear power plants

    International Nuclear Information System (INIS)

    Shi Jianzhong; Huang Chao; Hu Youqing

    2014-01-01

    The selection of the high pressure feedwater heater's safety valve usually follows the principle recommended by HEI standards in thermal power plant. However, the nuclear power plant's heaters generally need to accept a lots of drain from a moisture separator reheater (MSR). When the drain regulating valve was failure in fully open position, a large number of high pressure steam will directly goes into the heater. It make high-pressure heater have a risk of overpressure. Therefore, the safety valve selection of the heaters for nuclear power plants not only need to follow the HEI standards, but also need to check his capacity in certain special conditions. The paper established a calculation method to determine the static running point of the heaters based on characteristic equations of the feed water heater, drain regulating valve and steam extraction pipings, and energy balance principle. The method can be used to calculate the equilibrium pressure of various special running conditions, so further determine whether the capacity of the safety valve meets the requirements of safety and emissions. The method proposed in this paper not only can be used for nuclear power plants, can also be used for thermal power plants. (authors)

  14. Determining required valve performance for discrete control of PTO cylinders for wave energy

    DEFF Research Database (Denmark)

    Hansen, Rico Hjerm; Andersen, Torben Ole; Pedersen, Henrik C.

    2012-01-01

    investigates the required valve performance to achieve this energy efficient operation, while meeting basic dynamic requirements. The components making up the total energy loss during shifting is identified by analytically expressing the losses from the governing differential equations. From the analysis...... a framework for evaluating the adequacy of a valve’s response is established, and the analysis shows the results may be normalised for a wider range of systems. Finally, the framework is successfully applied to the Wavestar converter....

  15. Valve Disease

    Science.gov (United States)

    ... blood. There are 4 valves in the heart: tricuspid, pulmonary, mitral, and aortic. Two types of problems can disrupt blood flow through the valves: regurgitation or stenosis. Regurgitation is also called insufficiency or incompetence. Regurgitation happens when a valve doesn’ ...

  16. Main feedwater valve diagnostics at Waterford 3 nuclear generating station

    International Nuclear Information System (INIS)

    Fitzgerald, W.V.

    1991-01-01

    Pneumatically-operated control valves are coming under increasing scrutiny in nuclear power plants because of their relatively high incident rate. The theory behind a device that could make performance evaluation of these valves simpler and more effective was first described at the original EPRI Power Plant Valve Symposium. The development of this Diagnostic System was completed in 1989, and it was recently used to troubleshoot two main feedwater valves at Louisiana Power and Light's Waterford 3 Power Station. During a cold snap last December, these valves failed to respond to the input signal and, as a result, the plant came off line. An incident report had to be filed, and the plant chose to contact the original equipment manufacturer (OEM) for assistance. This paper describes the original incident involving these valves and then gives a brief description of the diagnostic system and how it works. The balance of the paper then reviews how the OEM and plant personnel utilized the system to evaluate each component of the control valve assembly (I/P transducer, positioner, volume boosters, actuator, and valve body assembly). By simply stroking the valve and monitoring pneumatic signals and valve position, the problem was traced to a malfunctioning positioner and a volume booster that was leaking. The problems were corrected and new performance signatures run for the valves using the system to document their improved operation. This case study demonstrates how new Diagnostic Technology along with OEM involvement can effectively address problems with pneumatically-operated control valves so that root-cause solutions can be implemented

  17. Mechanical Aortic Valve Replacement in Octogenarian

    Directory of Open Access Journals (Sweden)

    Irfan Tasoglu

    2013-10-01

    Full Text Available Aim: This study analyzes the long-term outcomes of mechanical aortic valve replacement in octogenarian patients. Material and Method: A retrospective review was performed on 23 octogenarian patients who underwent mechanical aortic valve replacement. Hospital mortality, postoperative intensive care unit stay, hospital stay and long-term results was examined. Estimates of the cumulative event mortality rate were calculated by the Kaplan-Meier method. Results: The mean age of all patients was 82.9±2.3 years and most were men (65.22%. The median ejection fraction was 45%. 73.91% of patients were in New York Heart Association class III-IV. Thirteen patients (56.52% in this study underwent combined procedure, the remaining 10 (43.48% patients underwent isolated aortic valve replacement. The most common valve size was 23 mm. The mean intensive care unit stay was 1.76±1.14 days. The mean hospital stay was 9.33±5.06 days. No complications were observed in 56.52% patients during their hospital stay. The overall hospital mortality was 8.7%. Follow-up was completed for all 23 patients. Median follow-up time was 33 months (1-108 months. Actuarial survival among discharged from hospital was 59% at 5 years. Discussion: Mechanical aortic valve replacement is a safe procedure in octogenarian patients and can be performed safely even in combined procedure.

  18. 241-AN-A valve pit manifold valves and position indication acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    VANDYKE, D.W.

    1999-08-25

    This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-A Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-A Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.

  19. Transfemoral Aortic Valve Implantation with the New Edwards Sapien 3 Valve for Treatment of Severe Aortic Stenosis-Impact of Valve Size in a Single Center Experience.

    Directory of Open Access Journals (Sweden)

    Jochen Wöhrle

    Full Text Available The third generation Edwards Sapien 3 (Edwards Lifesciences Inc., Irvine, California system was optimized to reduce residual aortic regurgitation and vascular complications.235 patients with severe symptomatic aortic stenosis were prospectively enrolled. Transcatheter aortic valve implantations (TAVI were performed without general anesthesia by transfemoral approach. Patients were followed for 30 days. Patients received 23mm (N = 77, 26mm (N = 91 or 29mm (N = 67 valve based on pre-procedural 256 multislice computer tomography. Mean oversizing did not differ between the 3 valves. There was no residual moderate or severe aortic regurgitation. Rate of mild aortic regurgitation and regurgitation index did not differ between groups. There was no switch to general anesthesia or conversion to surgery. Rate of major vascular complication was 3.0% with no difference between valve and delivery sheath sizes. Within 30 days rates of all cause mortality (2.6% and stroke (2.1% were low.In patients with severe aortic stenosis transfemoral TAVI with the Edwards Sapien 3 valve without general anesthesia was associated with a high rate of device success, no moderate or severe residual aortic regurgitation, low rates of major vascular complication, mortality and stroke within 30 days with no difference between the 3 valve sizes.ClinicalTrials.gov NCT02162069.

  20. Aortic Valve Stenosis

    Science.gov (United States)

    ... most cases, doctors don't know why a heart valve fails to develop properly, so it isn't something you could have prevented. Calcium buildup on the valve. With age, heart valves may accumulate deposits of calcium (aortic valve ...

  1. Assessment of structural valve deterioration of transcatheter aortic bioprosthetic balloon-expandable valves using the new European consensus definition.

    Science.gov (United States)

    Eltchaninoff, Hélène; Durand, Eric; Avinée, Guillaume; Tron, Christophe; Litzler, Pierre-Yves; Bauer, Fabrice; Dacher, Jean-Nicolas; Werhlin, Camille; Bouhzam, Najime; Bettinger, Nicolas; Candolfi, Pascal; Cribier, Alain

    2018-03-30

    Durability of transcatheter aortic bioprosthetic valves remains a major issue. Standardised definitions of deterioration and failure of bioprosthetic valves have recently been proposed. The aim of this study was to assess structural transcatheter valve deterioration (SVD) and bioprosthetic valve failure (BVF) using these new definitions. All TAVI patients implanted up to September 2012 with a minimal theoretical five-year follow-up were included. Systematic clinical and echocardiographic follow-up was performed annually. New standardised definitions were used to assess durability of transcatheter aortic bioprosthetic valves. From 2002 to 2012, 378 patients were included. Mean age and logistic EuroSCORE were 83.3±6.8 years and 22.8±13.1%. Thirty-day mortality was 13.2%. Nine patients had SVD including two severe forms and two patients had definite late BVF. The incidence of SVD and BVF at eight years was 3.2% (95% CI: 1.45-6.11) and 0.58% (95% CI: 0.15-2.75), respectively. Even though limited by the poor survival of the very high-risk/compassionate early population, our data do not demonstrate any alarm concerning transcatheter aortic valve durability. Careful prospective assessment in younger and lower-risk patients and comparison with surgical bioprosthetic valves are required for further assessment of the long-term durability of transcatheter valves.

  2. The error performance analysis over cyclic redundancy check codes

    Science.gov (United States)

    Yoon, Hee B.

    1991-06-01

    The burst error is generated in digital communication networks by various unpredictable conditions, which occur at high error rates, for short durations, and can impact services. To completely describe a burst error one has to know the bit pattern. This is impossible in practice on working systems. Therefore, under the memoryless binary symmetric channel (MBSC) assumptions, the performance evaluation or estimation schemes for digital signal 1 (DS1) transmission systems carrying live traffic is an interesting and important problem. This study will present some analytical methods, leading to efficient detecting algorithms of burst error using cyclic redundancy check (CRC) code. The definition of burst error is introduced using three different models. Among the three burst error models, the mathematical model is used in this study. The probability density function, function(b) of burst error of length b is proposed. The performance of CRC-n codes is evaluated and analyzed using function(b) through the use of a computer simulation model within CRC block burst error. The simulation result shows that the mean block burst error tends to approach the pattern of the burst error which random bit errors generate.

  3. Valve assembly

    International Nuclear Information System (INIS)

    Sandling, M.

    1981-01-01

    An improved valve assembly, used for controlling the flow of radioactive slurry, is described. Radioactive contamination of the air during removal or replacement of the valve is prevented by sucking air from the atmosphere through a portion of the structure above the valve housing. (U.K.)

  4. Mitral Valve Stenosis

    Science.gov (United States)

    ... the left ventricle from flowing backward. A defective heart valve fails to either open or close fully. Risk factors Mitral valve stenosis is less common today than it once was because the most common cause, ... other heart valve problems, mitral valve stenosis can strain your ...

  5. Technical evaluation: 300 Area steam line valve accident

    International Nuclear Information System (INIS)

    1993-08-01

    On June 7, 1993, a journeyman power operator (JPO) was severely burned and later died as a result of the failure of a 6-in. valve that occurred when he attempted to open main steam supply (MSS) valve MSS-25 in the U-3 valve pit. The pit is located northwest of Building 331 in the 300 Area of the Hanford Site. Figure 1-1 shows a layout of the 300 Area steam piping system including the U-3 steam valve pit. Figure 1-2 shows a cutaway view of the approximately 10- by 13- by 16-ft-high valve pit with its various steam valves and connecting piping. Valve MSS-25, an 8-in. valve, is located at the bottom of the pit. The failed 6-in. valve was located at the top of the pit where it branched from the upper portion of the 8-in. line at the 8- by 8- by 6-in. tee and was then ''blanked off'' with a blind flange. The purpose of this technical evaluation was to determine the cause of the accident that led to the failure of the 6-in. valve. The probable cause for the 6-in. valve failure was determined by visual, nondestructive, and destructive examination of the failed valve and by metallurgical analysis of the fractured region of the valve. The cause of the accident was ultimately identified by correlating the observed failure mode to the most probable physical phenomenon. Thermal-hydraulic analyses, component stress analyses, and tests were performed to verify that the probable physical phenomenon could be reasonably expected to produce the failure in the valve that was observed

  6. Redesign of emergency water supply system by-pass line from Cernavoda NPP Unit 1 and 2 using self regulating valves

    International Nuclear Information System (INIS)

    Tenescu, Mircea; Bigu, Melania; Nita, Iulian Pavel

    2010-01-01

    In this paper one considered improving the EWS (emergency water supply system) by-pass line in order to replace current manual operated valve with an self operated valve. This change is necessary in order to reduce the human error events in operation of the system in case of a DBE (design basis earthquake). The paper describes a theoretical and practical operation of a system using self regulating flow rate valves. Basically, the elimination of a possible human error in operating a system is important for nuclear safety in case of a DBE because it makes it avoidable in normal reactor cooling systems. The paper describes checking of the functioning of this equipment in operating conditions, investigating how it responds to various operating regimes. (authors)

  7. Aortic valve replacement and the stentless Freedom SOLO valve

    NARCIS (Netherlands)

    Wollersheim, L.W.L.M.

    2016-01-01

    Aortic valve stenosis has become the most prevalent valvular heart disease in Europe and North America, and is generally caused by age-related calcification of the aortic valve. For most patients, severe symptomatic aortic stenosis needs effective mechanical relief in the form of valve replacement

  8. Preliminary observations of gate valve flow interruption tests, Phase 2

    International Nuclear Information System (INIS)

    Steele, R. Jr.; DeWall, K.G.

    1990-01-01

    This paper presents preliminary observations from the US Nuclear Regulatory Commission/Idaho National Engineering Laboratory Flexible Wedge Gate Valve Qualification and Flow Interruption Test Program, Phase 2. The program investigated the ability of selected boiling water reactor (BWR) process line valves to perform their containment isolation function at high energy pipe break conditions and other more normal flow conditions. The fluid and valve operating responses were measured to provide information concerning valve and operator performance at various valve loadings so that the information could be used to assess typical nuclear industry motor operator sizing equations. Six valves were tested, three 6-in. isolation valves representative of those used in reactor water cleanup systems in BWRs and three 10-in. isolation valves representative of those used in BWR high pressure coolant injection (HPCI) steam lines. The concern with these normally open isolation valves is whether they will close in the event of a downstream pipe break outside of containment. The results of this testing will provide part of the technical insights for NRC efforts regarding Generic Issue 87 (GI-87), Failure of the HPCI Steam Line Without Isolation, which includes concerns about the uncertainties in gate valve motor operator sizing and torque switch settings for these BWR containment isolation valves. As of this writing, the Phase 2 test program has just been completed. Preliminary observations made in the field confirmed most of the results from the Phase 1 test program. All six valves closing in high energy water, high energy steam, and high pressure cold water require more force to close than would be calculated using the typical variables in the standard industry motor operator sizing equations

  9. Evaluation of a redesigned 3/4-inch uranium hexafluoride cylinder valve stem

    International Nuclear Information System (INIS)

    Zonner, L.A.; Wamsley, S.D.

    1978-01-01

    The performance of a redesigned 3/4-in. uranium hexafluoride cylinder valve stem has been evaluated at the Portsmouth Gaseous Diffusion Plant. Prototypes, machined from Monel bar stock and having a 45 0 tip angle instead of the 15 0 tip angle of the standard valve stem, were fabricated. Tests included: cyclic leak evaluation; flow restriction determination; wear testing with uranyl fluoride deposits in the valve seat; stress corrosion testing; field testing (in previously rejected valve bodies); and production leak testing. Because their overall test performance was excellent, actual production usage of the redesigned stems was initiated. The in-service performance of valves fitted with redesigned stems has been significantly superior to that of valves having the standard stems: rejection rates have been 0.7 and 16.6 percent, respectively. Recommendations are made to replace all 15 0 angle tip stems presently in service with new stems having a 45 0 angle tip and to specify the new stem tip design for future 3/4-in. valve purchases

  10. THE PROGNOSIS IN TRANSCATHETER AORTIC VALVE IMPLANTATION

    Directory of Open Access Journals (Sweden)

    T. E. Imaev

    2016-01-01

    Full Text Available Aim. To study the effect of transcatheter aortic valve implantation (TAVI, performed by different types of prostheses and various surgical access, on the prognosis of patients with critical aortic stenosis and comorbidities.Material and methods. Patients (n=130 that had consistently performed 80 TAVI by Edwards valve transfemoral (n=50 and transapical (n=30 access, as well as 50 transcatheter aortic valve replacement by CoreValve system were included into the study. Complications including perioperative mortality, total 30-day mortality, as well as post-hospital mortality were registered during aortic valve replacement, immediately after surgery, before the expiry of 30 days. Mean follow-up was 2.2 years (range 0.2 to 5.2 years.Results. Hospital mortality was on average 6.9%. 121 patients had been discharged from the department after the surgery. The number of deaths in the post-hospital period was 14.8%. Valve type and the type of access had no effect on post-hospital mortality. Men died more than 2.5 times often than women, regardless of age. Atrioventricular block, pacemaker implantation, and history of chronic obstructive pulmonary disease were the most significant prognostic factors. An important role of minor stroke and renal failure should be noted. Mortality did not depend on the surgical access or valve type. All parameters characterizing the intervention were significantly associated with mortality, both during and after surgery. The proportion of survivors at the end of the first year of observation using Corvalve system was 86.9%, Edwards valve by transfemoral access - 88% and Edwards valve by transapical access – 85.4% (insignificant differences for all groups, p>0.05. Two-year survival was 77.5%, 82.5% and 82.7%, respectively (also insignificant differences for all groups, p>0.05.Conclusion. TAVI is the method of choice, reasonable alternative approach for surgical valve replacement in patients with high surgical risk, although

  11. Risk Factors for Late Aortic Valve Dysfunction After the David V Valve-Sparing Root Replacement.

    Science.gov (United States)

    Esaki, Jiro; Leshnower, Bradley G; Binongo, Jose N; Lasanajak, Yi; McPherson, LaRonica; Guyton, Robert A; Chen, Edward P

    2017-11-01

    Valve-sparing root replacement (VSRR) is an established therapy for aortic root pathology. However, late aortic valve dysfunction requiring reoperation remains a primary concern of this procedure. This study examines risk factors for late aortic insufficiency (AI) and aortic stenosis (AS) after David V VSRR. A retrospective review from 2005 to 2015 at a US academic center identified 282 patients who underwent VSRR. Cox proportional hazards regression analysis was used to identify risk factors for late AI and AS after VSRR. The mean age was 46.4 years. Sixty-four patients (22.7%) had bicuspid valves, and 41 patients (14.5%) had Marfan syndrome. The incidence of reoperations was 27 (9.6%), and 42 cases (14.9%) presented with acute type A dissection. Operative mortality was 8 (2.8%). Seven-year survival was 90.9%. Seven-year cumulative incidence of reoperation, greater than 2+ AI and greater than moderate AS were 3.1%, 2.2%, and 0.8%, respectively. Multivariable analysis showed aortic root size 55 mm or larger (hazard ratio 3.44, 95% confidence interval: 1.27 to 9.29, p = 0.01) to be a risk factor for late AI whereas bicuspid valve (hazard ratio 16.07, 95% confidence interval: 3.12 to 82.68, p = 0.001) and cusp repair were found to be risk factors (hazard ratio 5.91, 95% confidence interval: 1.17 to 29.86, p = 0.03) for late AS. Valve-sparing root replacement can be performed with low operative risk and good overall long-term survival even in complex clinical settings. Durable valve function can be expected; however, aortic root size 55 cm or more, bicuspid valve anatomy, and cusp repair represent independent risk factors for late aortic valve dysfunction after these procedures. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Microfluidic sieve valves

    Science.gov (United States)

    Quake, Stephen R; Marcus, Joshua S; Hansen, Carl L

    2015-01-13

    Sieve valves for use in microfluidic device are provided. The valves are useful for impeding the flow of particles, such as chromatography beads or cells, in a microfluidic channel while allowing liquid solution to pass through the valve. The valves find particular use in making microfluidic chromatography modules.

  13. Quantitative assessment of an aortic and pulmonary valve function according to valve fenestration

    International Nuclear Information System (INIS)

    Mirkhani, S.H.; Golestani, M.G.; Hosini, M.; Kazemian, A.

    1999-01-01

    There are some reasons for malfunction of aortic and pulmonary valve like fibrosis, calcification, and atheroma. Although, in some papers fenestration were known as a pathologic sign, but it is not generally accepted, while this matter is important in choosing suitable Homograft Heart Valve. In this paper fenestrations and its size, numbers and situation effect was studied. We collected 98 hearts, the donors died because of accident, we excluded valves with atheroma, calcification, fibrosis and unequal cusps, 91 aortic and 93 pulmonary valves were given further consideration. We classified valves according to situation, number and size of fenestration. Each valve was tested with 104 cm of non-nal saline column pressure which is equal to 76 mm Hg. Valve efficacy was detected by fluid flow assay. With study of 184 valves, 95 had no fenestration, 64 had less than 2 fenestration and 25 had more than 2 fenestration. Valve efficacy in condition of less than 2 fenestration was more than others (p <0.01). Malfunction effects of fenestration increased in larger valve and it will be decreased if their situation would be marginal (free margin of cusp). In the comparison of aortic and pulmonary valve we saw that malfunction effect of fenestration in pulmonary valve was more than aortic valve. Our experience in Immam Khomeini Homograft Valve Bank has shown that a great deal of valves is fenestrated. It seems that fenestration must be considered as a quality criterion in homograft valve preparation, especially in pulmonary and large aortic valves; but complementary studies is necessary

  14. Improvement of a Pneumatic Control Valve with Self-Holding Function

    Science.gov (United States)

    Dohta, Shujiro; Akagi, Tetsuya; Kobayashi, Wataru; Shimooka, So; Masago, Yusuke

    2017-10-01

    The purpose of this study is to develop a small-sized, lightweight and low-cost control valve with low energy consumption and to apply it to the assistive system. We have developed some control valves; a tiny on/off valve using a vibration motor, and an on/off valve with self-holding function. We have also proposed and tested the digital servo valve with self-holding function using permanent magnets and a small-sized servo motor. In this paper, in order to improve the valve, an analytical model of the digital servo valve is proposed. And the simulated results by using the analytical model and identified parameters were compared with the experimental results. Then, the improved digital servo valve was designed based on the calculated results and tested. As a result, we realized the digital servo valve that can control the flow rate more precisely while maintaining its volume and weight compared with the previous valve. As an application of the improved valve, a position control system of rubber artificial muscle was built and the position control was performed successfully.

  15. The German Aortic Valve Registry (GARY): a nationwide registry for patients undergoing invasive therapy for severe aortic valve stenosis.

    Science.gov (United States)

    Beckmann, A; Hamm, C; Figulla, H R; Cremer, J; Kuck, K H; Lange, R; Zahn, R; Sack, S; Schuler, G C; Walther, T; Beyersdorf, F; Böhm, M; Heusch, G; Funkat, A K; Meinertz, T; Neumann, T; Papoutsis, K; Schneider, S; Welz, A; Mohr, F W

    2012-07-01

    Background The increasing prevalence of severe aortic valve defects correlates with the increase of life expectancy. For decades, surgical aortic valve replacement (AVR), under the use of extracorporeal circulation, has been the gold standard for treatment of severe aortic valve diseases. In Germany ~12,000 patients receive isolated aortic valve surgery per year. For some time, percutaneous balloon valvuloplasty has been used as a palliative therapeutic option for very few patients. Currently, alternatives for the established surgical procedures such as transcatheter aortic valve implantation (TAVI) have become available, but there are only limited data from randomized studies or low-volume registries concerning long-time outcome. In Germany, the implementation of this new technology into hospital care increased rapidly in the past few years. Therefore, the German Aortic Valve Registry (GARY) was founded in July 2010 including all available therapeutic options and providing data from a large quantity of patients.Methods The GARY is assembled as a complete survey for all invasive therapies in patients with relevant aortic valve diseases. It evaluates the new therapeutic options and compares them to surgical AVR. The model for data acquisition is based on three data sources: source I, the mandatory German database for external performance measurement; source II, a specific registry dataset; and source III, a follow-up data sheet (generated by phone interview). Various procedures will be compared concerning observed complications, mortality, and quality of life up to 5 years after the initial procedure. Furthermore, the registry will enable a compilation of evidence-based indication criteria and, in addition, also a comparison of all approved operative procedures, such as Ross or David procedures, and the use of different mechanical or biological aortic valve prostheses.Results Since the launch of data acquisition in July 2010, almost all institutions performing

  16. The wireless diagnostic system for motor operated valves

    International Nuclear Information System (INIS)

    Ito, Haruo; Akiyama, Michiaki; Suzuki, Syunichi

    2010-01-01

    To aim at maintenance optimization, a motor operated valve (MOV) diagnostic system called 'MOVDAS' has been developed by using new sensor technologies incorporating torque sensor into the MOV. It has been introduced into nuclear power plants operated by Japan Atomic Power Company (JAPC) for the support of Condition Based Maintenance (CBM). This system, directly checking the torque behavior of the MOV, accurately diagnoses the condition of the MOV during plant operation. Further for the ease of data collection and manpower saving, the wireless diagnostic system based on MOVDAS utilizing Personal Handyphone System (PHS) has been recently introduced into nuclear power plants in JAPC. (author)

  17. Diesel Engine Valve Clearance Detection Using Acoustic Emission

    Directory of Open Access Journals (Sweden)

    Fathi Elamin

    2010-01-01

    Full Text Available This paper investigated, using experimental method, the suitability of acoustic emission (AE technique for the condition monitoring of diesel engine valve faults. The clearance fault was adjusted experimentally in an exhaust valve and successfully detected and diagnosed in a Ford FSD 425 four-cylinder, four-stroke, in-line OHV, direct injection diesel engine. The effect of faulty exhaust valve clearance on engine performance was monitored and the difference between the healthy and faulty engine was observed from the recorded AE signals. The measured results from this technique show that using only time domain and frequency domain analysis of acoustic emission signals can give a superior measure of engine condition. This concludes that acoustic emission is a powerful and reliable method of detection and diagnosis of the faults in diesel engines and this is considered to be a unique approach to condition monitoring of valve performance.

  18. Experimental validation of the fluid–structure interaction simulation of a bioprosthetic aortic heart valve

    International Nuclear Information System (INIS)

    Kemp, I.; Dellimore, K.; Rodriguez, R.; Scheffer, C.; Blaine, D.; Weich, H.; Doubell, A.

    2013-01-01

    Experiments performed on a 19 mm diameter bioprosthetic valve were used to successfully validate the fluid–structure interaction (FSI) simulation of an aortic valve at 72 bpm. The FSI simulation was initialized via a novel approach utilizing a Doppler sonogram of the experimentally tested valve. Using this approach very close quantitative agreement (≤12.5 %) between the numerical predictions and experimental values for several key valve performance parameters, including the peak systolic transvalvular pressure gradient, rapid valve opening time and rapid valve closing time, was obtained. The predicted valve leaflet kinematics during opening and closing were also in good agreement with the experimental measurements.

  19. Check, check, double check: checking the autopilot causes distrust : Experimental studies on the effects of compulsive perseveration

    NARCIS (Netherlands)

    Dek, E.C.P.

    2015-01-01

    Obsessive-compulsive disorder (OCD) is characterized by persistent doubt. The majority of patients with OCD engage in repeated checking to reduce these feelings of uncertainty. However, numerous studies demonstrated that repetitive behavior ironically increases uncertainty: perseverative checking

  20. Design of Over Center Valves Based on Predictable Performance

    DEFF Research Database (Denmark)

    Hansen, M.R.; Andersen, T.O.; Pedersen, P.

    2004-01-01

    A typical oil hydraulic over center valve system and a time domain simulation model is introduced together with a hypothesis that flow force compensation should reduce the inherent oscillatory behavior of such hydraulic systems. A few results are shown from a parameter study that confirms...

  1. Recent experience with testing of parallel disc gate valves under accident flow conditions

    International Nuclear Information System (INIS)

    LaPointe, P.A.; Clayton, J.K.

    1992-01-01

    This paper presents the nuclear valve industry's latest and most extensive valve qualification test program experience. The test program includes a variety of 25 different gate and globe valves. All the test valves are power operated using either air, electric, or gas/hydraulic operators. The valves are categorized in size and pressure class so as to form a group of appropriate parent valve assemblies. Parent valve assembly qualification is used as the basis for qualification of candidate valve assemblies. The parent and candidate valve assemblies are representative of a nuclear plant's safety-related valve applications. The test program was performed in accordance with ANSI B16.41-1983 'Functional Qualification Requirements for Power Operated Active Valve Assemblies for Nuclear Power Plants.' The focus of this paper is on functional valve qualification test experience and specifically flow interruption testing to Annex G of the aforementioned test standard. Results of the flow test are summarized, including the coefficient of friction for each of the gate type valves reported. Information on valve size, pressure class, and actuator are given for all valves in the program. Although all valves performed extremely well, only selected test data are presented. The effects of the speed of operation and the effects of different fluid flow rates as they relate to the coefficient of friction between the valve disc and seat are discussed. The variation in the coefficient of friction based on other variables in the thrust equation, namely, differential pressure area is cited

  2. BIF butterfly valve life extension at WNP-2

    International Nuclear Information System (INIS)

    Armstrong, D.

    1991-01-01

    Primary containment purging, venting, inerting, and reactor building ventilation at the WNP-2 plant are accomplished with a series of large butterfly valves. A total of 31 valves which are similar in design, but of different sizes, employ an elastomer to achieve sealing integrity when closed. These valves, which were originally manufactured by BIF, a unit of General Signal, range in size from 18 to 84 inches in diameter. Service life in the plant was much less than desired for safety-related equipment, and several seal failures had been experienced shortly after valve overhaul. This program covers a design change made to enhance performance of the elastomer seal to achieve a very meaningful life extension. While numerous configurations of BIF valves exist, this work relates only to the model 657 unit assembled with an elastomer seal mounted onto the valve disc by a stainless steel clamping ring held with studs and nuts. The problems encountered, and the steps taken to resolve the deficiencies may, however, be applicable to other butterfly valve configurations

  3. Rotary pneumatic valve

    Science.gov (United States)

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  4. Scissor thrust valve actuator

    Science.gov (United States)

    DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.

    2006-08-29

    Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.

  5. Diaphragms in air-operated valves

    Energy Technology Data Exchange (ETDEWEB)

    Groeger, J.E.

    1996-12-01

    The author will present current issues related to diaphgrams in air-operated valves. Altran Materials Engineering, Inc., often performs root-cause analyses for nuclear power plant owners. The author will discuss various analyses that have been performed or are currently underway.

  6. Heavy gas valves

    Energy Technology Data Exchange (ETDEWEB)

    Steier, L [Vereinigte Armaturen Gesellschaft m.b.H., Mannheim (Germany, F.R.)

    1979-01-01

    Heavy gas valves must comply with special requirements. Apart from absolute safety in operation there are stringent requirements for material, sealing and ease of operation even in the most difficult conditions. Ball valves and single plate pipe gate valves lateral sealing rings have a dual, double sided sealing effect according to the GROVE sealing system. Single plate gate valves with lateral protective plates are suitable preferably for highly contaminated media. Soft sealing gate valves made of cast iron are used for low pressure applications.

  7. Application of hydraulic network analysis to motor operated butterfly valves in nuclear power plants

    International Nuclear Information System (INIS)

    Eldiwany, B.H.; Kalsi, M.S.

    1992-01-01

    This paper presents the application of hydraulic network analysis to evaluate the performance of butterfly valves in nuclear power plant applications. Required actuation torque for butterfly valves in high-flow applications is often dictated by peak dynamic torque. The peak dynamic torque, which occurs at some intermediate disc position, requires accurate evaluation of valve flow rate and pressure drop throughout the valve stroke. Valve flow rate and pressure drop are significantly affected by the valve flow characteristics and the hydraulic system characteristics, such as pumping capability, piping resistances, single and parallel flow paths, system hydrostatic pressure, and the location of the motor-operated valve (MOV) within the system. A hydraulic network analysis methodology that addresses the effect of these parameters on the MOV performance is presented. The methodology is based on well-established engineering principles. The application of this methodology requires detailed characteristics of both the MOV and the hydraulic system in which it is installed. The valve characteristics for this analysis can be obtained by flow testing or from the valve manufacturer. Even though many valve users, valve manufacturers, and engineering standards have recognized the importance of performing these analyses, none has provided a detailed procedure for doing so

  8. Minimising life cycle costs of automated valves in offshore platforms

    Energy Technology Data Exchange (ETDEWEB)

    Yli-Petays, Juha [Metso Automation do Brasil Ltda., Rio de Janeiro, RJ (Brazil); Niemela, Ismo [Metso Automation, Imatra (Finland)

    2012-07-01

    Automated process valves play an essential role in offshore platforms operation. If you are able to optimize their operation and maintenance activities you can receive extensive operational savings with minimal investment. Valves used in offshore platforms doesn't differentiate that much from the valves used in downstream but there are certain specialties, which makes the operations more challenging in offshore: Process valves are more difficult to access and maintain because of space limitations. Also spare part inventories and deliveries are challenging because of offshore platform's remote location. To overcome these challenges usage of digital positioners with diagnostic features has become more common because predictive maintenance capabilities enable possibilities to plan the maintenance activities and this way optimise the spare part orders regarding to valves. There are intelligent controllers available for control valves, automated on/off valves as well as ESD-valves and whole network of automated valves on platforms can be controlled by intelligent valve controllers. This creates many new opportunities in regards of optimized process performance or predictive maintenance point-of-view. By means of intelligent valve controllers and predictive diagnostics, condition monitoring and maintenance planning can also be performed remotely from an onshore location. Thus, intelligent valve controllers provide good way to minimize spending related to total cost of ownership of automated process valves. When purchase value of control valve represent 20% of TCO, intelligent positioner and predictive maintenance methods can enable as high as 30% savings over the life cycle of asset so basically it benefit savings higher than whole investment of monitored asset over its life cycle. This is mainly achieved through the optimized maintenance activities since real life examples has shown that with time based maintenance (preventive maintenance) approach 70% of

  9. Steel-fabricated butterfly valves for condenser circulating water system

    International Nuclear Information System (INIS)

    Kawase, Hiroshi; Yasuoka, Masahiro; Nanao, Teruaki.

    1979-01-01

    The steel-fabricated butterfly valves, which are large in general, and gave rubber linings inside to prevent the corrosion due to sea Water, are utilized for the condenser circulating water systems of thermal and nuclear power plants. Cast iron butterfly valves, having been used hitherto, have some technical irrationalities, such as corrosion prevention, the techniques for manufacturing large castings, severe thermal transient operation. On the contrary, the steel plate-fabricated butterfly valves have the following advantages; much superior characteristics in strength, rigidity and shock resistance, the streamline shape of valve plates, the narrow width between two flanges, superior execution of works for rubber lining, the perfect sealed structure, safety to vibration, light weight and easy maintenance. The structural design and the main specifications for the steel plate butterfly valves with the nominal bore from 1350 mm to 3500 mm are presented. Concerning the design criteria, the torque of operating butterfly valves and the strength of valve bodies, valve plates and valve stems are explained. The performance tests utilizing the mock-up valve were carried out for the measurements of stress distribution, the deformation of valve body, the endurance and the operating torque. In the welding standards for steel plate butterfly valves, three kinds of welded parts are classified, and the inspection method for each part is stipulated. The vibration of the valves induced by flow vortexes and cavitation is explained. (Nakai, Y.)

  10. Guide for the application and use of valves in power plant systems

    International Nuclear Information System (INIS)

    Brooks, B.P.; Fortier, R.E.; Kalsi, M.S.

    1990-08-01

    The purpose of this guidebook is to present, in a comprehensive manner, information and methods that have been successfully applied in the application and use of valves in power plant systems to reliably achieve their intended function(s). The information is also directly applicable to comparable system applications other than in power plants. The book's primary audience is expected to include a range of people who establish the engineering specifications of the valves, install and operate the valves in various systems, and perform required maintenance and repair of the valves. A secondary audience is anticipated to include system designers, engineering students, and others for whom a more indepth knowledge of the capabilities and limitations of valves leads to an improved understanding of the requirements necessary for enhanced valve performance. 76 refs., 135 figs., 24 tabs

  11. Mechanism study of freeze-valve for molten salt reactor (MSR)

    International Nuclear Information System (INIS)

    Qinhua, Zhang

    2014-01-01

    Molten salt reactor (MSR) is one of the fourth generation nuclear reactor, ordinary nuclear grade valve is unsuitable for MSR due to its special coolant and extraordinary working temperature. Freeze-valve is proposed as the most appropriate valve for MSR, but the technology issue about freeze-valve has not been report in recent decades. Its significance to test the comprehensive property of freeze-valve for the application in MSR. A high temperature molten salt test loop was built which the physics property of salt is similar to the coolant of MSR. The results indicate that freeze-valve has a good performance use in the molten salt circumstances of high temperature (max 700 deg. C) and strong corrosion (authors)

  12. Transcatheter aortic valve implantation of the direct flow medical aortic valve with minimal or no contrast

    Energy Technology Data Exchange (ETDEWEB)

    Latib, Azeem, E-mail: alatib@gmail.com [Interventional Cardiology Unit, San Raffaele Scientific Institute and EMO-GVM Centro Cuore Columbus, Milan (Italy); Maisano, Francesco; Colombo, Antonio [Interventional Cardiology Unit, San Raffaele Scientific Institute and EMO-GVM Centro Cuore Columbus, Milan (Italy); Klugmann, Silvio [Azienda Ospedaliera Niguarda Ca Granda, Piazza Ospedale Maggiore 3, Milan (Italy); Low, Reginald; Smith, Thomas [University of California Davis, Davis, CA 95616 (United States); Davidson, Charles [Northwestern Memorial Hospital, Chicago, IL 60611 (United States); Harreld, John H. [Clinical Imaging Analytics, Guerneville, CA (United States); Bruschi, Giuseppe; DeMarco, Federico [Azienda Ospedaliera Niguarda Ca Granda, Piazza Ospedale Maggiore 3, Milan (Italy)

    2014-06-15

    The 18F Direct Flow Medical (DFM) THV has conformable sealing rings, which minimizes aortic regurgitation and permits full hemodynamic assessment of valve performance prior to permanent implantation. During the DISCOVER trial, three patients who were at risk for receiving contrast media, two due to severe CKD and one due to a recent hyperthyroid reaction to contrast, underwent DFM implantation under fluoroscopic and transesophageal guidance without aortography during either positioning or to confirm the final position. Valve positioning was based on the optimal angiographic projection as calculated by the pre-procedural multislice CT scan. Precise optimization of valve position was performed to minimize transvalve gradient and aortic regurgitation. Prior to final implantation, transvalve hemodynamics were assessed invasively and by TEE. The post-procedure mean gradients were 7, 10, 11 mm Hg. The final AVA by echo was 1.70, 1.40 and 1.68 cm{sup 2}. Total aortic regurgitation post-procedure was none or trace in all three patients. Total positioning and assessment of valve performance time was 4, 6, and 12 minutes. Contrast was only used to confirm successful percutaneous closure of the femoral access site. The total contrast dose was 5, 8, 12 cc. Baseline eGFR and creatinine was 28, 22, 74 mL/min/1.73 m{sup 2} and 2.35, 2.98, and 1.03 mg/dL, respectively. Renal function was unchanged post-procedure: eGFR = 25, 35, and 96 mL/min/1.73 m{sup 2} and creatinine = 2.58, 1.99, and 1.03 mg/dL, respectively. In conclusion, the DFM THV provides the ability to perform TAVI with minimal or no contrast. The precise and predictable implantation technique can be performed with fluoro and echo guidance.

  13. Pressure locking and thermal binding of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, E.M.

    1996-12-01

    Pressure locking and thermal binding represent potential common mode failure mechanisms that can cause safety-related power-operated gate valves to fail in the closed position, thus rendering redundant safety-related systems incapable of performing their safety functions. Supplement 6 to Generic Letter 89-10, {open_quotes}Safety-Related Motor-Operated Gate Valve Testing and Surveillance,{close_quotes} provided an acceptable approach to addressing pressure locking and thermal binding of gate valves. More recently, the NRC has issued Generic Letter 95-07, {open_quotes}Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves,{close_quotes} to request that licensees take certain actions to ensure that safety-related power-operated gate valves that are susceptible to pressure locking or thermal binding are capable of performing their safety functions within the current licensing bases. Over the past two years, several plants in Region I determined that valves in certain systems were potentially susceptible to pressure locking and thermal binding, and have taken various corrective actions. The NRC Region I Systems Engineering Branch has been actively involved in the inspection of licensee actions in response to the pressure locking and thermal binding issue. Region I continues to maintain an active involvement in this area, including participation with the Office of Nuclear Reactor Regulation in reviewing licensee responses to Generic Letter 95-07.

  14. Intraoperative application of geometric three-dimensional mitral valve assessment package: a feasibility study.

    Science.gov (United States)

    Mahmood, Feroze; Karthik, Swaminathan; Subramaniam, Balachundhar; Panzica, Peter J; Mitchell, John; Lerner, Adam B; Jervis, Karinne; Maslow, Andrew D

    2008-04-01

    To study the feasibility of using 3-dimensional (3D) echocardiography in the operating room for mitral valve repair or replacement surgery. To perform geometric analysis of the mitral valve before and after repair. Prospective observational study. Academic, tertiary care hospital. Consecutive patients scheduled for mitral valve surgery. Intraoperative reconstruction of 3D images of the mitral valve. One hundred and two patients had 3D analysis of their mitral valve. Successful image reconstruction was performed in 93 patients-8 patients had arrhythmias or a dilated mitral valve annulus resulting in significant artifacts. Time from acquisition to reconstruction and analysis was less than 5 minutes. Surgeon identification of mitral valve anatomy was 100% accurate. The study confirms the feasibility of performing intraoperative 3D reconstruction of the mitral valve. This data can be used for confirmation and communication of 2-dimensional data to the surgeons by obtaining a surgical view of the mitral valve. The incorporation of color-flow Doppler into these 3D images helps in identification of the commissural or perivalvular location of regurgitant orifice. With improvements in the processing power of the current generation of echocardiography equipment, it is possible to quickly acquire, reconstruct, and manipulate images to help with timely diagnosis and surgical planning.

  15. Bentall Procedure Using Cryopreserved Valved Aortic Homografts

    Science.gov (United States)

    Christenson, Jan T.; Sierra, Jorge; Trindade, Pedro T.; Didier, Dominique; Kalangos, Afksendiyos

    2004-01-01

    The Bentall procedure is the standard operation for patients who have lesions of the ascending aorta associated with aortic valve disease. In many cases, however, mechanical prosthetic conduits are not suitable. There are few reports in the English-language medical literature concerning the mid- to long-term outcome of Bentall operations with cryopreserved homografts. Therefore, we reviewed our experience with this procedure and valved homografts. From January 1997 through December 2002, 21 patients underwent a Bentall operation with cryopreserved homografts at our institution. There were 14 males and 7 females; the mean age was 36 ± 21 years (range, 15–74 years). Eleven patients had undergone previous aortic valve surgery. All patients had aortic dilatation or aneurysms involving the ascending aorta. Indications for surgery included aortic valve stenosis or insufficiency, and aortic valve endocarditis (native valve or prosthetic). One patient had Takayasu's arteritis and 3 had Marfan syndrome. There was 1 hospital death (due to sepsis), but no other major postoperative complications. The mean hospital stay was 14 ± 7 days. Follow-up echocardiographic and computed tomographic scans were performed yearly. The mean follow-up was 34 months (6–72 months). Follow-up imaging revealed no calcifications or degenerative processes related to the homograft. Four patients had minimal valve regurgitation. Two patients died during follow-up. The 3-year actuarial survival rate was 85.7%. Our data suggest that the Bentall procedure with a valved homograft conduit is a safe procedure with excellent mid- to long-term results, comparable to results reported with aortic valve replacement with a homograft. PMID:15745290

  16. Method of accounting for code safety valve setpoint drift in safety analyses

    International Nuclear Information System (INIS)

    Rousseau, K.R.; Bergeron, P.A.

    1989-01-01

    In performing the safety analyses for transients that result in a challenge to the reactor coolant system (RCS) pressure boundary, the general acceptance criterion is that the peak RCS pressure not exceed the American Society of Mechanical Engineers limit of 110% of the design pressure. Without crediting non-safety-grade pressure mitigating systems, protection from this limit is mainly provided by the primary and secondary code safety valves. In theory, the combination of relief capacity and setpoints for these valves is designed to provide this protection. Generally, banks of valves are set at varying setpoints staggered by 15- to 20-psid increments to minimize the number of valves that would open by an overpressure challenge. In practice, however, when these valves are removed and tested (typically during a refueling outage), setpoints are sometimes found to have drifted by >50 psid. This drift should be accounted for during the performance of the safety analysis. This paper describes analyses performed by Yankee Atomic Electric Company (YAEC) to account for setpoint drift in safety valves from testing. The results of these analyses are used to define safety valve operability or acceptance criteria

  17. Analysis of gravity feed in KSNP for the development of low power and shutdown PSA

    International Nuclear Information System (INIS)

    Jang, Seung Cheol; Lim, Ho Gon; Park, Jin Hee

    2005-03-01

    A check valve has been widely used to prevent the reverse flow in many systems including nuclear power plant. A swing disk type check valve (swing check valve) is preferentially adopted because this type of check valve has the characteristics of quick closing before flow reversal will occur. In addition swing check valve can obtain large enough opening area such that the flow through the valve is relatively unobstructed. However, the swing check valve requires the minimum fluid velocity to overcome the disk weight in the forward flow direction. This minimum velocity is usually given by the manufacturer otherwise the formula from CRANE or EPRI can be used to calculate the required minimum velocity for a certain swing check valve. When the fluid velocity through the swing check valve is not sufficient enough to meet the minimum velocity, the swing disk increases flow resistance which in turn changes the fluid velocity. Additionally, when the flow conditions vary with time, the swing check valve model combined with fluid governing equations is required to fully track the behavior of the flow. Accordingly, the most of the thermal-hydraulic nuclear safety codes have the swing check valve model. RELAP5/MOD3 describes swing check valve with the angular momentum equation about the swing disk. The angular momentum equation in the swing check valve model of RELAP5/MOD3 has the tendency of larger disk angle prediction for a given fluid velocity. This model over-estimates the pressure difference between swing disk due to the excessive prediction by pressure-driven torque and misleading geometry assumption. As a result, for a given flow line with swing check valve, the mass flow rate is under-estimated. In the present study, new check valve model is developed based on the Botros and Raymeyer's model. Also, this model is implemented to the thermal-hydraulic system code, MARS. The present model has a good agreement with the experiment of single swing check valve. Also, this model

  18. Effect of the mitral valve on diastolic flow patterns

    International Nuclear Information System (INIS)

    Seo, Jung Hee; Vedula, Vijay; Mittal, Rajat; Abraham, Theodore; Dawoud, Fady; Luo, Hongchang; Lardo, Albert C.

    2014-01-01

    The leaflets of the mitral valve interact with the mitral jet and significantly impact diastolic flow patterns, but the effect of mitral valve morphology and kinematics on diastolic flow and its implications for left ventricular function have not been clearly delineated. In the present study, we employ computational hemodynamic simulations to understand the effect of mitral valve leaflets on diastolic flow. A computational model of the left ventricle is constructed based on a high-resolution contrast computed-tomography scan, and a physiological inspired model of the mitral valve leaflets is synthesized from morphological and echocardiographic data. Simulations are performed with a diode type valve model as well as the physiological mitral valve model in order to delineate the effect of mitral-valve leaflets on the intraventricular flow. The study suggests that a normal physiological mitral valve promotes the formation of a circulatory (or “looped”) flow pattern in the ventricle. The mitral valve leaflets also increase the strength of the apical flow, thereby enhancing apical washout and mixing of ventricular blood. The implications of these findings on ventricular function as well as ventricular flow models are discussed

  19. Coronary artery assessment by multidetector computed tomography in patients with prosthetic heart valves

    International Nuclear Information System (INIS)

    Habets, Jesse; Mali, Willem P.T.M.; Budde, Ricardo P.J.; Brink, Renee B.A. van den; Uijlings, Ruben; Spijkerboer, Anje M.; Chamuleau, Steven A.J.

    2012-01-01

    Patients with prosthetic heart valves may require assessment for coronary artery disease. We assessed whether valve artefacts hamper coronary artery assessment by multidetector CT. ECG-gated or -triggered CT angiograms were selected from our PACS archive based on the presence of prosthetic heart valves. The best systolic and diastolic axial reconstructions were selected for coronary assessment. Each present coronary segment was scored for the presence of valve-related artefacts prohibiting coronary artery assessment. Scoring was performed in consensus by two observers. Eighty-two CT angiograms were performed on a 64-slice (n = 27) or 256-slice (n = 55) multidetector CT. Eighty-nine valves and five annuloplasty rings were present. Forty-three out of 1160 (3.7%) present coronary artery segments were non-diagnostic due to valve artefacts (14/82 patients). Valve artefacts were located in right coronary artery (15/43; 35%), left anterior descending artery (2/43; 5%), circumflex artery (14/43; 32%) and marginal obtuse (12/43; 28%) segments. All cobalt-chrome containing valves caused artefacts prohibiting coronary assessment. Biological and titanium-containing valves did not cause artefacts except for three specific valve types. Most commonly implanted prosthetic heart valves do not hamper coronary assessment on multidetector CT. Cobalt-chrome containing prosthetic heart valves preclude complete coronary artery assessment because of severe valve artefacts. circle Most commonly implanted prosthetic heart valves do not hamper coronary artery assessment circle Prosthetic heart valve composition determines the occurrence of prosthetic heart valve-related artefacts circle Bjoerk-Shiley and Sorin tilting disc valves preclude diagnostic coronary artery segment assessment. (orig.)

  20. Modeling of Dynamic Fluid Forces in Fast Switching Valves

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck; Johansen, Per; Pedersen, Henrik Clemmensen

    2015-01-01

    Switching valves experience opposing fluid forces due to movement of the moving member itself, as the surrounding fluid volume must move to accommodate the movement. This movement-induced fluid force may be divided into three main components; the added mass term, the viscous term and the socalled...... history term. For general valve geometries there are no simple solution to either of these terms. During development and design of such switching valves, it is therefore, common practice to use simple models to describe the opposing fluid forces, neglecting all but the viscous term which is determined...... based on shearing areas and venting channels. For fast acting valves the opposing fluid force may retard the valve performance significantly, if appropriate measures are not taken during the valve design. Unsteady Computational Fluid Dynamics (CFD) simulations are available to simulate the total fluid...

  1. Force measuring valve assemblies, systems including such valve assemblies and related methods

    Science.gov (United States)

    DeWall, Kevin George [Pocatello, ID; Garcia, Humberto Enrique [Idaho Falls, ID; McKellar, Michael George [Idaho Falls, ID

    2012-04-17

    Methods of evaluating a fluid condition may include stroking a valve member and measuring a force acting on the valve member during the stroke. Methods of evaluating a fluid condition may include measuring a force acting on a valve member in the presence of fluid flow over a period of time and evaluating at least one of the frequency of changes in the measured force over the period of time and the magnitude of the changes in the measured force over the period of time to identify the presence of an anomaly in a fluid flow and, optionally, its estimated location. Methods of evaluating a valve condition may include directing a fluid flow through a valve while stroking a valve member, measuring a force acting on the valve member during the stroke, and comparing the measured force to a reference force. Valve assemblies and related systems are also disclosed.

  2. Design and performance of General Electric boiling water reactor main steam line isolation valves

    International Nuclear Information System (INIS)

    Rockwell, D.A.; van Zylstra, E.H.

    1976-08-01

    An extensive test program has been completed by the General Electric Company in cooperation with the Commonwealth Edison Company on the basic design type of large main steam line isolation valves used on General Electric Boiling Water Reactors. Based on a total of 40 tests under simulated accident conditions covering a wide range of mass flows, mixture qualities, and closing times, it was concluded that the commercially available valves of this basic type will close completely and reliably as required. Analytical methods to predict transient effects in the steam line and valve after postulated breaks were refined and confirmed by the test program

  3. Fate of remnant sinuses of Valsalva in patients with bicuspid and trileaflet valves undergoing aortic valve, ascending aorta, and aortic arch replacement.

    Science.gov (United States)

    Milewski, Rita Karianna; Habertheuer, Andreas; Bavaria, Joseph E; Siki, Mary; Szeto, Wilson Y; Krause, Eric; Korutla, Varun; Desai, Nimesh D; Vallabhajosyula, Prashanth

    2017-08-01

    In patients presenting with aortic valvulopathy with concomitant ascending aortic aneurysm, surgical management of the sinus of Valsalva segment remains undefined, especially for moderately dilated aortic roots. In patients with this pathology undergoing aortic valve replacement with supracoronary ascending aorta replacement, we assessed the fate of the remnant preserved sinus of Valsalva segment stratified by aortic valve morphology and pathology. From 2002 to 2015, 428 patients underwent elective aortic valve replacement with supracoronary ascending aorta replacement. Patients were stratified on the basis of valvular morphology (bicuspid aortic valve [n = 254] and tricuspid aortic valve [n = 174]), valvular pathology (bicuspid aortic valve with aortic stenosis [n = 178], bicuspid aortic valve with aortic insufficiency [n = 76], tricuspid aortic valve with aortic stenosis [n = 61], tricuspid aortic valve with aortic insufficiency [n = 113]), and preoperative sinus of Valsalva dimensions (45 mm). Kaplan-Meier analysis revealed no significant difference in freedom from reoperation in tricuspid aortic valve versus bicuspid aortic valve (P = .576). Multivariable Cox regression model performed with sinus of Valsalva dimensions at baseline and follow-up as time-varying covariates did not adversely affect survival. A repeated-measure, mixed-effects model constructed to assess longitudinal sinus of Valsalva trends revealed that the retained sinus of Valsalva dimensions remain stable over long-term follow-up (discharge to ≥10 years), irrespective of valvular morphology/pathology (bicuspid aortic valve with aortic insufficiency, tricuspid aortic valve with aortic insufficiency, tricuspid aortic valve with aortic stenosis) and preoperative sinus of Valsalva groups (45 mm). In patients with nonaneurysmal sinuses of Valsalva undergoing aortic valve replacement with supracoronary ascending aorta replacement, the sinus segment can be preserved irrespective of

  4. FIZCON, ENDF/B Cross-Sections Redundancy Check

    International Nuclear Information System (INIS)

    Dunford, Charles L.

    2007-01-01

    1 - Description of program or function: FIZCON is a program for checking that an evaluated data file has valid data and conforms to recommended procedures. Version 7.01 (April 2005): set success flag after return from beginning; fixed valid level check for an isomer; fixed subsection energy range test in ckf9; changed lower limit on potential scattering test; fixed error in j-value test when l=0 and i=0; added one more significant figure to union grid check and sum up output messages; partial fission cross sections mt=19,20,21 and 38 did not require secondary energy distributions in file 5; corrected product test for elastic scattering; moved potential scattering test to psyche. Version 7.02 (May 2005): Fixed resonance parameter sum test. 2 - Method of solution: FIZCON can recognise the difference between ENDF-6 and ENDF-5 formats and performs its tests accordingly. Some of the tests performed include: data arrays are in increasing energy order; resonance parameter widths add up to the total; Q-values are reasonable and consistent; no required sections are missing and all cover the proper energy range; secondary distributions are normalized to 1.0; energy conservation in decay spectra. Optional tests can be performed to check the redundant cross sections, and algorithms can be used to check for possible incorrect entry of data values (Deviant Point test)

  5. A remote control valve

    International Nuclear Information System (INIS)

    Cachard, Maurice de; Dumont, Maurice.

    1976-01-01

    This invention concerns a remote control valve for shutting off or distributing a fluid flowing at a high rate and low pressure. Among the different valves at present in use, electric valves are the most recommended for remote control but their reliability is uncertain and they soon become costly when large diameter valves are used. The valve described in this invention does away with this drawback owing to its simplicity and the small number of moving parts, this makes it particularly reliable. It mainly includes: a tubular body fitted with at least one side opening; at least one valve wedge for this opening, coaxial with the body, and mobile; a mobile piston integral with this wedge. Several valves to the specifications of this invention can be fitted in series (a shut-off valve can be used in conjunction with one or more distribution valves). The fitting and maintenance of the valve is very simple owing to its design. It can be fabricated in any material such as metals, alloys, plastics and concrete. The structure of the valve prevents the flowing fluid from coming into contact with the outside environment, thereby making it particularly suitable in the handling of dangerous or corrosive fluids. Finally, the opening and shutting of the valve occurs slowly, thereby doing away with the water hammer effect so frequent in large bore pipes [fr

  6. Hardfacing materials and processes for valve applications

    International Nuclear Information System (INIS)

    Matthews, S.J.; Crook, P.

    1982-01-01

    The subject of hardfacing is a very high technology effort especially in the valve industry. The technology is manifested by the need for sophisticated high performance hardfacing alloys required to resist the demanding environments of fluid flow control valve service. High technology is also found in the automated methods currently being used to efficiently deposit high quality hardfacing overlays. 3 figures, 3 tables

  7. SAFETY SHUTOFF VALVE

    DEFF Research Database (Denmark)

    2010-01-01

    It is disclosed a shut-off valve which acts automatically and has a fully mechanical performance with respect to the loosing of the tower-shape part balance under the effect of the special acceleration Which is arisen from the quakes waves or serious vibrations, while such vibrations are mainly r...

  8. Infective Endocarditis of the Aortic Valve with Anterior Mitral Valve Leaflet Aneurysm

    NARCIS (Netherlands)

    Tomsic, Anton; Li, Wilson W. L.; van Paridon, Marieke; Bindraban, Navin R.; de Mol, Bas A. J. M.

    2016-01-01

    Mitral valve leaflet aneurysm is a rare and potentially devastating complication of aortic valve endocarditis. We report the case of a 48-year-old man who had endocarditis of the native aortic valve and a concomitant aneurysm of the anterior mitral valve leaflet. Severe mitral regurgitation occurred

  9. What is a good health check? An interview study of health check providers' views and practices.

    Science.gov (United States)

    Stol, Yrrah H; Asscher, Eva C A; Schermer, Maartje H N

    2017-10-02

    Health checks identify (risk factors for) disease in people without symptoms. They may be offered by the government through population screenings and by other providers to individual users as 'personal health checks'. Health check providers' perspective of 'good' health checks may further the debate on the ethical evaluation and possible regulation of these personal health checks. In 2015, we interviewed twenty Dutch health check providers on criteria for 'good' health checks, and the role these criteria play in their practices. Providers unanimously formulate a number of minimal criteria: Checks must focus on (risk factors for) treatable/preventable disease; Tests must be reliable and clinically valid; Participation must be informed and voluntary; Checks should provide more benefits than harms; Governmental screenings should be cost-effective. Aspirational criteria mentioned were: Follow-up care should be provided; Providers should be skilled and experienced professionals that put the benefit of (potential) users first; Providers should take time and attention. Some criteria were contested: People should be free to test on any (risk factor for) disease; Health checks should only be performed in people at high risk for disease that are likely to implement health advice; Follow up care of privately funded tests should not drain on collective resources. Providers do not always fulfil their own criteria. Their reasons reveal conflicts between criteria, conflicts between criteria and other ethical values, and point to components in the (Dutch) organisation of health care that hinder an ethical provision of health checks. Moreover, providers consider informed consent a criterion that is hard to establish in practice. According to providers, personal health checks should meet the same criteria as population screenings, with the exception of cost-effectiveness. Providers do not always fulfil their own criteria. Results indicate that in thinking about the ethics of health

  10. Application of new designed butterfly type intermediate valve for nuclear steam turbine

    International Nuclear Information System (INIS)

    Matsumura, Kazuhiro; Kawamata, Susumu; Fujita, Isao; Taketomo, Seiki.

    1991-01-01

    To cope with a large capacity nuclear steam turbine, a butterfly type intermediate valve has been developed. Compared to the conventional valve, or globe valve, the butterfly valve has the following design features: a) Higher thermal efficiency due to lower pressure loss, b) Easier maintenance due to simplified construction, and c) Lower station cost due to the smaller size of the valve assembly. An experiment with a scaled-down test valve was carried out using compressed air. Subsequently a full-scale valve was tested using steam under actual steam conditions. As a result, these tests gave us no problems. The first nuclear turbine (1100MW) equipped with a butterfly valve is operating satisfactorily with good performance as expected. (author)

  11. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    Science.gov (United States)

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  12. Outcomes of Reoperative Valve Replacement in Patients with Prosthetic Valve Endocarditis: A 20-Year Experience

    Directory of Open Access Journals (Sweden)

    Young Woong Kim

    2018-02-01

    Full Text Available Background: Prosthetic valve endocarditis (PVE is a serious complication of cardiac valve replacement, and many p atients with P VE r equire r eoperation. The aim of t his study was to r eview our institutional 2 0 -year experience of surgical reoperative valve replacement in patients with PVE. Methods: A retrospective study was performed on 84 patients (mean age, 54.8±12.7 years; 51 males who were diagnosed with PVE and underwent reoperative valve replacement from January 1995 to December 2016. Results: PVE was found in 1 valve in 61 cases (72.6%, and in 2 or more valves in 23 cases (27.4%. The median follow-up duration was 47.3 months (range, 0 to 250 months. Postoperative complications occurred in 39 patients (46.4%. Reinfection occurred in 6 cases, all within 1 year. The freedom from reinfection rate at 5 years was 91.0%±3.5%. The overall survival rates at 5 and 10 years were 64.4%±5.8% and 54.3%±7.3%, respectively. In stepwise multivariable Cox proportional hazard models, older age (hazard ratio [HR], 1.48; 95% confidence interval [CI], 1.05 to 2.10; p=0.027 and cardiopulmonary bypass (CPB time (HR, 1.03; 95% CI, 1.00 to 1.0 1; p =0 . 0 33 e merged a s independent risk f actors f or d eath. Conclusion: Older age and a longer CPB time were associated with an increased risk of overall mortality in PVE patients.

  13. Surgery of the aortic root: should we go for the valve-sparing root reconstruction or the composite graft-valve replacement is still the first choice of treatment for these patients?

    Science.gov (United States)

    Lamana, Fernando de Azevedo; Dias, Ricardo Ribeiro; Duncan, Jose Augusto; Faria, Leandro Batisti de; Malbouisson, Luiz Marcelo Sa; Borges, Luciano de Figueiredo; Mady, Charles; Jatene, Fábio Biscegli

    2015-01-01

    To compare the results of the root reconstruction with the aortic valve-sparing operation versus composite graft-valve replacement. From January 2002 to October 2013, 324 patients underwent aortic root reconstruction. They were 263 composite graft-valve replacement and 61 aortic valve-sparing operation (43 reimplantation and 18 remodeling). Twenty-six percent of the patients were NYHA functional class III and IV; 9.6% had Marfan syndrome, and 12% had bicuspid aortic valve. There was a predominance of aneurysms over dissections (81% vs. 19%), with 7% being acute dissections. The complete follow-up of 100% of the patients was performed with median follow-up time of 902 days for patients undergoing composite graft-valve replacement and 1492 for those undergoing aortic valve-sparing operation. In-hospital mortality was 6.7% and 4.9%, respectively for composite graft-valve replacement and aortic valve-sparing operation (ns). During the late follow-up period, there was 0% moderate and 15.4% severe aortic regurgitation, and NYHA functional class I and II were 89.4% and 94%, respectively for composite graft-valve replacement and aortic valve-sparing operation (ns). Root reconstruction with aortic valve-sparing operation showed lower late mortality (P=0.001) and lower bleeding complications (P=0.006). There was no difference for thromboembolism, endocarditis, and need of reoperation. The aortic root reconstruction with preservation of the valve should be the operation being performed for presenting lower late mortality and survival free of bleeding events.

  14. Dynamic testing of POSI-SEAL motor-operated butterfly valves using strain gages

    International Nuclear Information System (INIS)

    Richard, M.C.; Chiou, D.

    1994-01-01

    Utilities operating nuclear power plants recognize that the correct functioning of all motor-operated valves, and particularly those in safety-related systems, is of paramount importance. The U.S. Nuclear Regulatory Commission has issued Generic Letter 89-10 relative to this concern. Operability must be demonstrated under design-basis conditions. In order to demonstrate operability of motor-operated butterfly valves, the valve stem torque must be determined. The valve stem torque is a function of seat material, stem packing, stem bearing friction, and hydrodynamic lift and drag. The total valve operating hydrodynamic torque can be predicted using the valve manufacturer's data and the differential pressure. In order to validate the valve manufacturer's data, the actual total valve hydrodynamic torque is measured using strain gages mounted directly on the valve stem. This paper presents the results of comparing the predicted total valve operating hydrodynamic torque with the actual total valve operating hydrodynamic torque for six POSI-SEAL Class 150 high performance butterfly valves

  15. Novel Active Combustion Control Valve

    Science.gov (United States)

    Caspermeyer, Matt

    2014-01-01

    This project presents an innovative solution for active combustion control. Relative to the state of the art, this concept provides frequency modulation (greater than 1,000 Hz) in combination with high-amplitude modulation (in excess of 30 percent flow) and can be adapted to a large range of fuel injector sizes. Existing valves often have low flow modulation strength. To achieve higher flow modulation requires excessively large valves or too much electrical power to be practical. This active combustion control valve (ACCV) has high-frequency and -amplitude modulation, consumes low electrical power, is closely coupled with the fuel injector for modulation strength, and is practical in size and weight. By mitigating combustion instabilities at higher frequencies than have been previously achieved (approximately 1,000 Hz), this new technology enables gas turbines to run at operating points that produce lower emissions and higher performance.

  16. Cellular regulation of the structure and function of aortic valves

    Directory of Open Access Journals (Sweden)

    Ismail El-Hamamsy

    2010-01-01

    Full Text Available The aortic valve was long considered a passive structure that opens and closes in response to changes in transvalvular pressure. Recent evidence suggests that the aortic valve performs highly sophisticated functions as a result of its unique microscopic structure. These functions allow it to adapt to its hemodynamic and mechanical environment. Understanding the cellular and molecular mechanisms involved in normal valve physiology is essential to elucidate the mechanisms behind valve disease. We here review the structure and developmental biology of aortic valves; we examine the role of its cellular parts in regulating its function and describe potential pathophysiological and clinical implications.

  17. Mitral Valve Replacement with a Pulmonary Autograft in an Infant

    Directory of Open Access Journals (Sweden)

    Yong Ho Jeong

    2018-04-01

    Full Text Available A 76-day-old infant weighing 3.4 kg was referred for surgical intervention for severe mitral valve stenoinsufficiency caused by leaflet fibrosis and calcification. He had experienced a cerebral infarction in the left middle cerebral artery territory, which was deemed attributable to an embolism of a calcified particle from the dysmorphic mitral valve. Because mitral valve replacement using a prosthetic valve was not feasible in this small baby, mitral valve replacement with a pulmonary autograft was performed. After a brief period of extracorporeal membrane oxygenation (ECMO support, he was weaned from ECMO and was discharged home without further cardiovascular complications.

  18. Transcatheter aortic valve-in-valve treatment of degenerative stentless supra-annular Freedom Solo valves: A single centre experience.

    Science.gov (United States)

    Cockburn, James; Dooley, Maureen; Parker, Jessica; Hill, Andrew; Hutchinson, Nevil; de Belder, Adam; Trivedi, Uday; Hildick-Smith, David

    2017-02-15

    Redo surgery for degenerative bioprosthetic aortic valves is associated with significant morbidity and mortality. Report results of valve-in-valve therapy (ViV-TAVI) in failed supra-annular stentless Freedom Solo (FS) bioprostheses, which are the highest risk for coronary occlusion. Six patients with FS valves (mean age 78.5 years, 50% males). Five had valvular restenosis (peak gradient 87.2 mm Hg, valve area 0.63 cm 2 ), one had severe regurgitation (AR). Median time to failure was 7 years. Patients were high risk (mean STS/Logistic EuroScore 10.6 15.8, respectively). FS valves ranged from 21 to 25 mm. Successful ViV-TAVI was achieved in 4/6 patients (67%). Of the unsuccessful cases, (patient 1 and 2 of series) patient 1 underwent BAV with simultaneous aortography which revealed left main stem occlusion. The procedure was stopped and the patient went forward for repeat surgery. Patient 2 underwent successful ViV-TAVI with a 26-mm CoreValve with a guide catheter in the left main, but on removal coronary obstruction occurred, necessitating valve snaring into the aorta. Among the successful cases, (patients 3, 4, 5, 6) the TAVIs used were CoreValve Evolut R 23 mm (n = 3), and Lotus 23 mm (n = 1). In the successful cases the peak gradient fell from 83.0 to 38.3 mm Hg. No patient was left with >1+ AR. One patient had a stroke on Day 2, with full neurological recovery. Two patients underwent semi-elective pacing for LBBB and PR >280 ms. ViV-TAVI in stentless Freedom Solo valves is high risk. The risk of coronary occlusion is high. The smallest possible prosthesis (1:1 sizing) should be used, and strategies to protect the coronary vessels must be considered. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  19. Outlet strut fracture and leaflet escape of Bjork-Shiley convexo-concave valve.

    Science.gov (United States)

    Uchino, Gaku; Yoshida, Hideo; Sakoda, Naoya; Hattori, Shigeru; Kawabata, Takuya; Saiki, Munehiro; Fujita, Yasufumi; Yunoki, Keiji; Hisamochi, Kunikazu; Mine, Yoshinari

    2017-06-01

    Prosthetic valve fracture is a serious complication and may arise in patient post-valve replacement. We experienced an outlet strut fracture and leaflet escape of a Bjork-Shiley convexo-concave valve. We performed an emergency redo mitral valve replacement and successfully retrieved the fractured strut and escaped leaflet from superficial femoral artery and the abdominal aorta. The patient showed an uneventful postoperative recovery.

  20. Cardioscopic tricuspid valve repair in a beating ovine heart.

    Science.gov (United States)

    Umakanthan, Ramanan; Ghanta, Ravi K; Rangaraj, Aravind T; Lee, Lawrence S; Laurence, Rita G; Fox, John A; Mihaljevic, Tomislav; Bolman, Ralph M; Cohn, Lawrence H; Chen, Frederick Y

    2009-04-01

    Open heart surgery is commonly associated with cardiopulmonary bypass and cardioplegic arrest. The attendant risks of cardiopulmonary bypass may be prohibitive in high-risk patients. We present a novel endoscopic technique of performing tricuspid valve repair without cardiopulmonary bypass in a beating ovine heart. Six sheep underwent sternotomy and creation of a right heart shunt to eliminate right atrial and right ventricular blood for clear visualization. The superior vena cava, inferior vena cava, pulmonary artery, and coronary sinus were cannulated, and the blood flow from these vessels was shunted into the pulmonary artery via a roller pump. The posterior leaflet of the tricuspid valve was partially excised to create tricuspid regurgitation, which was confirmed by Doppler echocardiography. A 7.0-mm fiberoptic videoscope was inserted into the right atrium to visualize the tricuspid valve. Under cardioscopic vision, an endoscopic needle driver was inserted into the right atrium, and a concentric stitch was placed along the posterior annulus to bicuspidize the tricuspid valve. Doppler echocardiography confirmed reduction of tricuspid regurgitation. All animals successfully underwent and tolerated the surgical procedure. The right heart shunt generated a bloodless field, facilitating cardioscopic tricuspid valve visualization. The endoscopic stitch resulted in annular plication and functional tricuspid valve bicuspidization, significantly reducing the degree of tricuspid regurgitation. Cardioscopy enables less invasive, beating-heart tricuspid valve surgery in an ovine model. This technique may be useful in performing right heart surgery without cardiopulmonary bypass in high-risk patients.

  1. Which valve is which?

    Directory of Open Access Journals (Sweden)

    Pravin Saxena

    2015-01-01

    Full Text Available A 25-year-old man presented with a history of breathlessness for the past 2 years. He had a history of operation for Tetralogy of Fallot at the age of 5 years and history suggestive of Rheumatic fever at the age of 7 years. On echocardiographic examination, all his heart valves were severely regurgitating. Morphologically, all the valves were irreparable. The ejection fraction was 35%. He underwent quadruple valve replacement. The aortic and mitral valves were replaced by metallic valve and the tricuspid and pulmonary by tissue valve.

  2. Mitral Valve Prolapse

    Science.gov (United States)

    Mitral valve prolapse (MVP) occurs when one of your heart's valves doesn't work properly. The flaps of the valve are "floppy" and ... to run in families. Most of the time, MVP doesn't cause any problems. Rarely, blood can ...

  3. Stem thrust prediction model for Westinghouse wedge gate valves with linkage type stem-to-disk connection

    International Nuclear Information System (INIS)

    Wang, J.K.; Sharma, V.; Kalsi, M.S.

    1996-01-01

    The Electric Power Research Institute (EPRI) conducted a comprehensive research program with the objective of providing nuclear utilities with analytical methods to predict motor operated valve (MOV) performance under design basis conditions. This paper describes the stem thrust calculation model developed for evaluating the performance of one such valve, the Westinghouse flexible wedge gate valve. These procedures account for the unique functional characteristics of this valve design. In addition, model results are compared to available flow loop and in situ test data as a basis for evaluating the performance of the valve model

  4. Stem thrust prediction model for Westinghouse wedge gate valves with linkage type stem-to-disk connection

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J.K.; Sharma, V.; Kalsi, M.S. [Kalsi Engineering, Inc., Sugar Land, TX (United States)] [and others

    1996-12-01

    The Electric Power Research Institute (EPRI) conducted a comprehensive research program with the objective of providing nuclear utilities with analytical methods to predict motor operated valve (MOV) performance under design basis conditions. This paper describes the stem thrust calculation model developed for evaluating the performance of one such valve, the Westinghouse flexible wedge gate valve. These procedures account for the unique functional characteristics of this valve design. In addition, model results are compared to available flow loop and in situ test data as a basis for evaluating the performance of the valve model.

  5. Functional and performance evaluation of 28 bar hot shutdown passive valve (HSPV) at integral test loop (ITL) for advanced heavy water reactor (AHWR)

    International Nuclear Information System (INIS)

    Sapra, M.K.; Kundu, S.; Pal, A.K.; Sharma, B.S.V.G.

    2007-02-01

    During reactor shutdown in advanced heavy water reactor (AHWR), core decay heat is removed by eight isolation condensers (IC) submerged in gravity driven water pool. Passive valves are provided on the down stream of each isolation condenser. On increase in steam drum pressure beyond a set value, these passive valves start opening and establish steam flow by natural circulation between the four steam drums and corresponding isolation condensers under hot shutdown and therefore they are termed as Hot Shut Down Passive Valves (HSPVs). The HSPV is a self acting type valve requiring no external energy, i.e. neither air nor electric supply for actuation. This feature makes the valve functioning independent of external systems such as compressed air supply or electric power supply, thereby providing inherent safety feature in line with reactor design philosophy. The high pressure and high temperature HSPV s for nuclear reactor use, are non-standard valves and therefore not manufactured by the valve industry worldwide. In the process of design and development of a prototype valve for AHWR, a 28 bar HSPV was configured and successfully tested at Integral Test Loop (ITL) at Engineering Hall No.7. During ten continuous experiments spread over 14 days, the HSPV has proved its functional capabilities and its intended use in decay heat removal system. The in-situ pressure setting and calibration aspect of HSPV has also been successfully established during these experiments. This report gives an insight into the HSPV's functional behavior and role in reactor decay heat removal system. The report not only provides the quantitative measure of performance for 28 bar HSPV in terms of valve characteristics, pressure controllability, linearity and hysteresis but also sets qualitative indicators for prototype 80 bar HSPV, being developed for AHWR. (author)

  6. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area....... This study evaluates the authors' clinical experience with Top Hat supra-annular aortic valve size selection, and the technical aspects of implantation. METHODS: Between January 1999 and October 2005, a total of 251 consecutive patients underwent 252 aortic valve replacements with Top Hat supra...... required unplanned coronary bypass, and 30-day mortality was 2.0% (5/251), indicating a good safety profile for the valves implanted in this series. CONCLUSION: The general distribution of implant sizes in the US indicates that cardiac surgeons may be under-sizing the Top Hat supra-annular aortic valve...

  7. Hydrodynamic characterization of a passive shape memory alloy valve

    International Nuclear Information System (INIS)

    Waddell, A M; Punch, J; Stafford, J; Jeffers, N

    2014-01-01

    Next generation high-performance electronics will have large heat fluxes (>10 2 W/cm 2 ) and an alternative approach to traditional air cooling is required. An attractive solution is micro-channel cooling and micro-valves will be required for refined flow control in the supporting micro-fluidic systems. A NiTi Shape Memory Alloy (SMA) micro-valve design was hydrodynamically characterized in this work to obtain the valve loss coefficient (K) from pressure measurements. The hydrodynamic characterization was important as in the flow regime of the micro-fluidic system K is sensitive to Reynolds number (Re) and geometry. Static replicas of the SMA valve geometry were studied for low Reynolds numbers (110 – 220) in a 1x1 mm CSA miniature channel. The loss coefficients were found to be sensitive to flow rate and decreased rapidly with an increase in Re. The SMA valve was compared to a similar gate micro-valve and loss across both valves was of the same order of magnitude. The valve loss coefficients obtained in this work are important parameters in the modeling and design of micro-fluidic cooling systems.

  8. Transapical aortic valve implantation without angiography: proof of concept.

    Science.gov (United States)

    Ferrari, Enrico; Sulzer, Christopher; Marcucci, Carlo; Rizzo, Elena; Tozzi, Piergiorgio; von Segesser, Ludwig K

    2010-06-01

    Cardiac computed tomographic scans, coronary angiograms, and aortographies are routinely performed in transcatheter heart valve therapies. Consequently, all patients are exposed to multiple contrast injections with a following risk of nephrotoxicity and postoperative renal failure. The transapical aortic valve implantation without angiography can prevent contrast-related complications. Between November 2008 and November 2009, 30 consecutive high-risk patients (16 female, 53.3%) underwent transapical aortic valve implantation without angiography. The landmarks identification, the stent-valve positioning, and the postoperative control were routinely performed under transesophageal echocardiogram and fluoroscopic visualization without contrast injections. Mean age was 80.1 +/- 8.7 years. Mean valve gradient, aortic orifice area, and ejection fraction were 60.3 +/- 20.9 mm Hg, 0.7 +/- 0.16 cm(2), and 0.526 +/- 0.128, respectively. Risk factors were pulmonary hypertension (60%), peripheral vascular disease (70%), chronic pulmonary disease (50%), previous cardiac surgery (13.3%), and chronic renal insufficiency (40%) (mean blood creatinine and urea levels: 96.8 +/- 54 microg/dL and 8.45 +/- 5.15 mmol/L). Average European System for Cardiac Operative Risk Evaluation was 32.2 +/- 13.3%. Valve deployment in the ideal landing zone was 96.7% successful and valve embolization occurred once. Thirty-day mortality was 10% (3 patients). Causes of death were the following: intraoperative ventricular rupture (conversion to sternotomy), right ventricular failure, and bilateral pneumonia. Stroke occurred in one patient at postoperative day 9. Renal failure (postoperative mean blood creatinine and urea levels: 91.1 +/- 66.8 microg/dL and 7.27 +/- 3.45 mmol/L), myocardial infarction, and atrioventricular block were not detected. Transapical aortic valve implantation without angiography requires a short learning curve and can be performed routinely by experienced teams. Our report

  9. Minimally invasive mitral valve repair in osteogenesis imperfecta.

    Science.gov (United States)

    Tagliasacchi, Isabella; Martinelli, Luigi; Bardaro, Leopoldo; Chierchia, Sergio

    2017-10-01

    Osteogenesis imperfecta is a disorder of the connective tissue that affects several structures including heart valves. However, cardiac surgery is associated with high mortality and morbidity rates. In a 48-year-old man with osteogenesis imperfecta and mitral valve prolapse, we performed the first successful mitral valve repair by right anterior mini-thoracotomy. At the 1-year follow-up, he was asymptomatic and echocardiography confirmed the initial success. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  10. DIAGNOSTICS AND TREATMENT OF MITRAL VALVE PROLAPSE

    Directory of Open Access Journals (Sweden)

    D. A. Kuzhel

    2010-01-01

    Full Text Available The mitral valve prolapse (MVP is one of the most inconsistent diagnose. In the most cases patients with MVP have the good long-term prognosis, and therapy is aimed at reduction in psychovegetative dysfunction. Careful follow-up and timely cardiosurgical correction should be performed, if necessary, in patients with classical MPV. The choice method in these cases is the mitral valve plasty.

  11. Development of a smart type motor operated valve for nuclear power plants

    Science.gov (United States)

    Kim, Chang-Hwoi; Park, Joo-Hyun; Lee, Dong-young; Koo, In-Soo

    2005-12-01

    In this paper, the design concept of the smart type motor operator valve for nuclear power plant was described. The development objective of the smart valve is to achieve superior accuracy, long-term reliability, and ease of use. In this reasons, developed smart valve has fieldbus communication such as deviceNet and Profibus-DP, auto-tuning PID controller, self-diagnostics, and on-line calibration capabilities. And also, to achieve pressure, temperature, and flow control with internal PID controller, the pressure sensor and transmitter were included in this valve. And, temperature and flow signal acquisition port was prepared. The developed smart valve will be performed equipment qualification test such as environment, EMI/EMC, and vibration in Korea Test Lab. And, the valve performance is tested in a test loop which is located in Seoul National University Lab. To apply nuclear power plant, the software is being developed according to software life cycle. The developed software is verified by independent software V and V team. It is expected that the smart valve can be applied to an existing NPPs for replacing or to a new nuclear power plants. The design and fabrication of smart valve is now being processed.

  12. Replacement of outboard main steam isolation valves in a boiling water reactor plant

    Energy Technology Data Exchange (ETDEWEB)

    Schlereth, J.R.; Pennington, D.

    1996-12-01

    Most Boiling Water Reactor plants utilize wye pattern globe valves for main steam isolation valves for both inboard and outboard isolation. These valves have required a high degree of maintenance attention in order to pass the plant local leakage rate testing (LLRT) requirements at each outage. Northern States Power made a decision in 1993 to replace the outboard valves at it`s Monticello plant with double disc gate valves. The replacement of the outboard valves was completed during the fall outage in 1994. During the spring outage in April of 1996 the first LLRT testing was performed with excellent results. This presentation will address the decision process, time requirements and planning necessary to accomplish the task as well as the performance results and cost effectiveness of replacing these components.

  13. Replacement of outboard main steam isolation valves in a boiling water reactor plant

    International Nuclear Information System (INIS)

    Schlereth, J.R.; Pennington, D.

    1996-01-01

    Most Boiling Water Reactor plants utilize wye pattern globe valves for main steam isolation valves for both inboard and outboard isolation. These valves have required a high degree of maintenance attention in order to pass the plant local leakage rate testing (LLRT) requirements at each outage. Northern States Power made a decision in 1993 to replace the outboard valves at it's Monticello plant with double disc gate valves. The replacement of the outboard valves was completed during the fall outage in 1994. During the spring outage in April of 1996 the first LLRT testing was performed with excellent results. This presentation will address the decision process, time requirements and planning necessary to accomplish the task as well as the performance results and cost effectiveness of replacing these components

  14. Mitral valve surgery in the adult Marfan syndrome patient.

    Science.gov (United States)

    Bhudia, Sunil K; Troughton, Richard; Lam, Buu-Khanh; Rajeswaran, Jeevanantham; Mills, William R; Gillinov, A Marc; Griffin, Brian P; Blackstone, Eugene H; Lytle, Bruce W; Svensson, Lars G

    2006-03-01

    Because mitral valve dysfunction in adults with Marfan syndrome is poorly characterized, this study compares mitral valve pathophysiology and morphology with that of myxomatous mitral disease, documents types of mitral valve operations, and assesses long-term survival and durability of mitral valve surgery in Marfan patients. From May 1975 to June 2000, 27 adults with Marfan syndrome underwent mitral valve surgery. Their valve pathophysiology and morphology was compared with that of 119 patients with myxomatous mitral disease undergoing surgery from September 1995 to March 1999. Survival and repair durability were assessed at follow-up. Compared with myxomatous disease patients, Marfan patients had less posterior leaflet prolapse (44% versus 70%, p = 0.01), more bileaflet (44% versus 28%, p = 0.09) and anterior leaflet prolapse (11% versus 3%, p = 0.07), and presented earlier for surgery (age 41 +/- 12 years versus 57 +/- 13, p Marfan patients had longer and thinner leaflets. Mitral valve repair was performed less frequently in Marfan (16 of 27, 59%) than myxomatous disease patients (112 of 119, 94%). There were no hospital deaths; at 10 years, survival was 80% and freedom from reoperation 96%, with only 1 reoperation among the 16 repairs. Mitral valve pathophysiology and morphology differ between Marfan and myxomatous mitral valve diseases. Valve repair in Marfan patients is durable and gives acceptable long-term results, even in adults who present with advanced mitral valve pathology. With increasing use of the modified David reimplantation operation and sparing of the aortic valve, mitral valve repair is a greater imperative, particularly since we have not had to reoperate on any Marfan patients with reimplantations.

  15. Real-time numerical evaluation of dynamic tests with sudden closing of valves in piping systems

    International Nuclear Information System (INIS)

    Geidel, W.; Leimbach, K.R.

    1979-01-01

    The sudden closing of a valve in a piping system causes a build-up of pressure which, in turn, causes severe vibrations of the structural system. The licensing procedure calls for on-site tests to determine the dynamic effects of such closing of valves, and to check the stresses and displacements against the allowable ones. The measurements include time histories of displacements, accelerations and internal pressure. The computer program KWUROHR for the static and dynamic analysis of piping systems has been used by KWU and several subcontractors during the past four vears. This program has been extended by adding a subroutine package which computes time histories of displacements, accelerations and stresses resulting from the input of measured time histories of internal pressures at selected locations. The computer algorithm establishes the topological connectivity between the internal pressure measuring locations, to set up a logic for linear pressure interpolation between these points and pressure steps at reducers and valves. A minimum number of input points is required to give realistic results. (orig.)

  16. Heart Valve Diseases

    Science.gov (United States)

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  17. Incidence of cerebrovascular accidents in patients undergoing minimally invasive valve surgery.

    Science.gov (United States)

    LaPietra, Angelo; Santana, Orlando; Mihos, Christos G; DeBeer, Steven; Rosen, Gerald P; Lamas, Gervasio A; Lamelas, Joseph

    2014-07-01

    Minimally invasive valve surgery has been associated with increased cerebrovascular complications. Our objective was to evaluate the incidence of cerebrovascular accidents in patients undergoing minimally invasive valve surgery. We retrospectively reviewed all the minimally invasive valve surgery performed at our institution from January 2009 to June 2012. The operative times, lengths of stay, postoperative complications, and mortality were analyzed. A total of 1501 consecutive patients were identified. The mean age was 73 ± 13 years, and 808 patients (54%) were male. Of the 1501 patients, 206 (13.7%) had a history of a cerebrovascular accident, and 225 (15%) had undergone previous heart surgery. The procedures performed were 617 isolated aortic valve replacements (41.1%), 658 isolated mitral valve operations (43.8%), 6 tricuspid valve repairs (0.4%), 216 double valve surgery (14.4%), and 4 triple valve surgery (0.3%). Femoral cannulation was used in 1359 patients (90.5%) and central cannulation in 142 (9.5%). In 1392 patients (92.7%), the aorta was clamped, and in 109 (7.3%), the surgery was performed with the heart fibrillating. The median aortic crossclamp and cardiopulmonary bypass times were 86 minutes (interquartile range [IQR], 70-107) minutes and 116 minutes (IQR, 96-143), respectively. The median intensive care unit length of stay was 47 hours (IQR, 29-74), and the median postoperative hospital length of stay was 7 days (IQR, 5-10). A total of 23 cerebrovascular accidents (1.53%) and 38 deaths (2.53%) had occurred at 30 days postoperatively. Minimally invasive valve surgery was associated with an acceptable stroke rate, regardless of the cannulation technique. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  18. Design of pneumatic proportional flow valve type 5/3

    Science.gov (United States)

    Laski, P. A.; Pietrala, D. S.; Zwierzchowski, J.; Czarnogorski, K.

    2017-08-01

    In this paper the 5/3-way pneumatic, proportional flow valve was designed and made. Stepper linear actuator was used to move the spool. The valve is controlled by the controlled based on a AVR microcontroller. Virtual model of the valve was created in CAD. The real element was made based on a standard 5/3-way manually actuated valve with hand lever, which was dismounted and replaced by linear stepper motor. All the elements was mounted in a specially made housing. The controller consists of microcontroller Atmega16, integrated circuit L293D, display, two potentiometers, three LEDs and six buttons. Series of research was also conducted. Simulation research were performed using CFD by the Flow Simulation addition to SolidWorks. During the experiments the valve characteristics of flow and pressure was determined.

  19. Prosthetic valve endocarditis after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; De Backer, Ole; Thyregod, Hans G H

    2015-01-01

    BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an advancing mode of treatment for inoperable or high-risk patients with aortic stenosis. Prosthetic valve endocarditis (PVE) after TAVI is a serious complication, but only limited data exist on its incidence, outcome, and procedural......%) were treated conservatively and 1 with surgery. Four patients (22%) died from endocarditis or complications to treatment, 2 of those (11%) during initial hospitalization for PVE. An increased risk of TAVI-PVE was seen in patients with low implanted valve position (hazard ratio, 2.8 [1.1-7.2]), moderate...

  20. A study on flow distribution for integrated hybrid actuator by analysis of reed valve

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Jang Mi; Kang, Seung Hwan; Ko, Han Seo [Sungkyunkwan University, Suwon (Korea, Republic of); Goo, Nam Seo; Li, Yong Zhe [Konkuk University, Seoul (Korea, Republic of)

    2016-05-15

    Many studies have been conducted recently on an integrated hybrid actuator due to the increasing need for unmanned aircraft and guided weapons. In this study, flow distribution was analyzed for a reed valve which was used for flow regulation to improve the performance of the actuator. By using a Fluid structural interaction (FSI) technique with Computational fluid dynamics (CFD) having a moving mesh, numerical analysis was performed according to the thickness, shape and driving frequency of the reed valve. From the calculated results, the maximum performance of the reed valve was found at the valve thickness of 0.15 mm and the driving frequency of 250 Hz for a no-load state. The optimum thickness and shape for the valve for each driving frequency were also realized.

  1. The nordic aortic valve intervention (NOTION) trial comparing transcatheter versus surgical valve implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Søndergaard, Lars; Ihlemann, Nikolaj

    2013-01-01

    Degenerative aortic valve (AV) stenosis is the most prevalent heart valve disease in the western world. Surgical aortic valve replacement (SAVR) has until recently been the standard of treatment for patients with severe AV stenosis. Whether transcatheter aortic valve implantation (TAVI) can...

  2. Delayed-onset streptococcus pyogenes endophthalmitis following Ahmed glaucoma valve implantation.

    Science.gov (United States)

    Bayraktar, Zerrin; Kapran, Ziya; Bayraktar, Sükrü; Acar, Nur; Unver, Yaprak Banu; Gök, Kemran

    2005-01-01

    To report a case of delayed-onset Streptococcus pyogenes endophthalmitis following implantation of an Ahmed glaucoma valve. A 10-year-old patient presented with acute endophthalmitis 1 year after Ahmed glaucoma valve implantation. The conjunctiva and Tenon's capsule over the valve plate had been penetrated by one of the polypropylene fixation sutures. The valve was removed, and pars plana vitrectomy was performed. Vitreous specimens and removal of the discharge over the plate revealed Streptococcus pyogenes. This is the first documented case of Streptococcus pyogenes endophthalmitis following Ahmed glaucoma valve implantation. We think the conjunctival buttonhole caused by the polypropylene suture provided an entry site for the infection. (c) Japanese Ophthalmological Society 2005.

  3. Gasoline New Timing and Flux Adjustable Rotary Valve Design (Hereinafter: Rotary Valve

    Directory of Open Access Journals (Sweden)

    Du huiqi

    2016-01-01

    Full Text Available Conventional gasoline engine with an umbrella valve control cylinder intake and exhaust, in order to achieve sealing effect, the valve is driven by the spring force; at the same time, when the cam opens the valve to overcome the spring force acting. Sealing the better, the more power consumed in the engine mechanical losses, the valve mechanism consumes about 30%, which is not a small loss! This article describes a new type of rotary valve is to significantly reduce mechanical losses, so as to achieve energy saving purposes.

  4. Fluid control valves

    International Nuclear Information System (INIS)

    Rankin, J.

    1980-01-01

    A fluid control valve is described in which it is not necessary to insert a hand or a tool into the housing to remove the valve seat. Such a valve is particularly suitable for the control of radioactive fluids since maintenance by remote control is possible. (UK)

  5. What Is Heart Valve Surgery?

    Science.gov (United States)

    ... working correctly. Most valve replacements involve the aortic Tricuspid valve and mitral valves. The aortic valve separates ... where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t ...

  6. What Is Heart Valve Disease?

    Science.gov (United States)

    ... and replacing it with a man-made or biological valve. Biological valves are made from pig, cow, or human ... the valve. Man-made valves last longer than biological valves and usually don’t have to be ...

  7. Early results of gate valve flow interruption blowdown tests

    International Nuclear Information System (INIS)

    DeWall, K.G.

    1988-01-01

    The preliminary results of the USNRC/INEL high-energy BWR line break flow interruption testing are presented. Two representative nuclear valve assemblies were cycled under design basis Reactor Water Cleanup pipe break conditions to provide input for the technical basis for resolving the Nuclear Regulatory Commission's Generic Issue 87. The effects of the blowdown hydraulic loadings on valve operability, especially valve closure stem forces, were studied. The blowdown tests showed that, given enough thrust, typical gate valves will close against the high flow resulting from a line break. The tests also showed that proper operator sizing depends on the correct identification of values for the sizing equation. Evidence exists that values used in the past may not be conservative for all valve applications. The tests showed that improper operator lock ring installation following test or maintenance can invalidate in-situ test results and prevent the valve from performing its design function. 2 refs., 12 figs., 2 tabs

  8. Relief valve testing study

    International Nuclear Information System (INIS)

    BROMM, R.D.

    2001-01-01

    Reclosing pressure-actuated valves, commonly called relief valves, are designed to relieve system pressure once it reaches the set point of the valve. They generally operate either proportional to the differential between their set pressure and the system pressure (gradual lift) or by rapidly opening fully when the set pressure is reached (pop action). A pop action valve allows the maximum fluid flow through the valve when the set pressure is reached. A gradual lift valve allows fluid flow in proportion to how much the system pressure has exceeded the set pressure of the valve (in the case of pressure relief) or has decreased below the set pressure (vacuum relief). These valves are used to protect systems from over and under pressurization. They are used on boilers, pressure vessels, piping systems and vacuum systems to prevent catastrophic failures of these systems, which can happen if they are under or over pressurized beyond the material tolerances. The construction of these valves ranges from extreme precision of less than a psi tolerance and a very short lifetime to extremely robust construction such as those used on historic railroad steam engines that are designed operate many times a day without changing their set pressure when the engines are operating. Relief valves can be designed to be immune to the effects of back pressure or to be vulnerable to it. Which type of valve to use depends upon the design requirements of the system

  9. Comparative study between CardiaMed valves (freely floating valve leaflets versus St. Jude Medical (fixed valve leaflets in mitral valve replacement surgery

    Directory of Open Access Journals (Sweden)

    Mostafa Ahmed

    2017-09-01

    Conclusions: CardiaMed freely floating leaflet prostheses showed good hemodynamic characteristics. The prosthesis adequately corrects hemodynamics and is safe and no worse than the St. Jude Medical valve in the mitral valve position.

  10. Allowable outage analysis for the LOFT CIS and reflood assist bypass valves

    International Nuclear Information System (INIS)

    Trainer, J.E.; Matthews, S.D.

    1977-06-01

    To determine the outage time allowable for a typical 1 of 2 redundant valve configuration, a Markov model was created to analyze the various operating states for the valves. Since no performance criteria have been specified, an availability model was constructed with regard to the valve outage

  11. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  12. Transapical JenaValve in a patient with mechanical mitral valve prosthesis.

    LENUS (Irish Health Repository)

    O' Sullivan, Katie E

    2014-01-29

    We report the first case of transcatheter aortic valve replacement implantation using JenaValve™ in a patient with mechanical mitral valve prosthesis. We believe that the design features of this valve may be particularly suited for use in this setting. © 2014 Wiley Periodicals, Inc.

  13. Aortic valve surgery of the 21st century: sutureless AVR versus TAVI.

    Science.gov (United States)

    Costache, Victor S; Moldovan, Horatiu; Arsenescu, Catalina; Costache, Andreea

    2018-04-01

    Surgical aortic valve replacement (sAVR) has been a safe, effective and time-proven technique and is still the standard of care all over the world for aortic valve treatment. The vast majority of centers perform this procedure by doing a median sternotomy with several disadvantages. While many others specialties went minimally invasive decades ago, in cardiovascular field transcatheter valve implantation was the first minimally invasive valvular procedure that gained rapid worldwide acceptance. Transcatheter valve replacement (TAVR) is now marketed as a procedure that should be performed under local anesthesia, by an interventional cardiologist via trans femoral route with no other healthcare professional invited to the patient selection or case planning. An increasing number of surgeons are promoting minimally invasive aortic valve replacement, which is gaining grounds, especially with the help of the new sutureless valve technology. With these two new technologies emerging, legitimate questions arise and need to be answered - which has the longest durability, lower complication rate and lower overall mortality.

  14. Butterfly valves for seawater

    International Nuclear Information System (INIS)

    Yamanaka, Katsuto

    1991-01-01

    Recently in thermal and nuclear power stations and chemical plants which have become large capacity, large quantity of cooling water is required, and mostly seawater is utilized. In these cooling water systems, considering thermal efficiency and economy, the pipings become complex, and various control functions are demanded. For the purpose, the installation of shut-off valves and control valves for pipings is necessary. The various types of valves have been employed, and in particular, butterfly valves have many merits in their function, size, structure, operation, maintenance, usable period, price and so on. The corrosion behavior of seawater is complicated due to the pollution of seawater, therefore, the environment of the valves used for seawater became severe. The structure and the features of the butterfly valves for seawater, the change of the structure of the butterfly valves for seawater and the checkup of the butterfly valves for seawater are reported. The corrosion of metallic materials is complicatedly different due to the locating condition of plants, the state of pipings and the condition of use. The corrosion countermeasures for butterfly valves must be examined from the synthetic viewpoints. (K.I.)

  15. Supra-annular valve strategy for an early degenerated transcatheter balloon-expandable heart valve.

    Science.gov (United States)

    Kamioka, Norihiko; Caughron, Hope; Corrigan, Frank; Block, Peter; Babaliaros, Vasilis

    2018-01-23

    Currently, there are no recommendations regarding the selection of valve type for a transcatheter heart valve (THV)-in-THV procedure. A supra-annular valve design may be superior in that it results in a larger effective orifice area and may have a lower chance of valve thrombosis after THV-in-THV. In this report, we describe the use of a supra-annular valve strategy for an early degenerated THV. © 2018 Wiley Periodicals, Inc.

  16. An original tool for checking energy performance and certification of buildings by means of Artificial Neural Networks

    International Nuclear Information System (INIS)

    Buratti, C.; Barbanera, M.; Palladino, D.

    2014-01-01

    Highlights: • ANN used as a tool for evaluating energy performance of buildings. • Training, validation, and testing of Neural Network with real energy certificates data. • Global energy performance index was chosen as a target of ANN. • A good correlation and a minimum error was found with certificates data. • A new energy index was defined in order to check the energy certificates. - Abstract: The Energy Performance Buildings Directive (EPBD) was issued to provide a common strategy for all European countries and to implement several actions for improving energy efficiency of buildings, responsible for 40% of energy consumption. Energy Performance Certificates are provided as a tool to evaluate the energy performance of buildings; however, costly and time-consuming controls are necessary to verify the accuracy of the set and declared data. Useful tools could be the Artificial Neural Networks (ANN), whereby it is possible to estimate the energy consumptions from specific parameters, to evaluate the accuracy of data in the energy certificates, and to identify the certificates needing accurate control. In this study, an Artificial Neural Network was developed based on approximately 6500 energy certificates (2700 are self-declaration) received by the Umbria Region (central Italy), in order to evaluate the global energy consumption of buildings from several and specific parameters reported in certificates. Data was checked in compliance with energy standards and only the correct certificates were used to train the Neural Network. The implemented Neural Network was tested with database data and a good correlation was found; in particular the energy performance calculated with the Neural Network presents an error greater than 15 kW h/m 2 year with respect to the real value of global energy performance index in only 3.6% of cases. Finally, a Neural Energy Performance Index (N.E.P.I.) was defined, in order to verify the accuracy of the energy certificates; the

  17. EPRI flow-loop/in situ test program for motor-operated valves

    International Nuclear Information System (INIS)

    Hosler, J.F.; Dorfman, L.S.

    1994-01-01

    The Electric Power Research Institute is undertaking a comprehensive research program to develop and validate methods for predicting the performance of common motor-operated gate, global, and butterfly valves. To assess motor-operated valve (MOV) performance characteristics and provide a basis for methods validation, full-scale testing was conducted on 62 MOVs. Tests were performed in four flow-loop facilities and in nine nuclear units. Forty-seven gate, five globe, and 10 butterfly valves were tested under a wide range of flow and differential pressure conditions. The paper describes the test program scope, test configurations, instrumentation and data acquisition, testing approach, and data analysis methods. Key results are summarized

  18. How checking breeds doubt: reduced performance in a simple working memory task.

    Science.gov (United States)

    Harkin, Ben; Kessler, Klaus

    2009-06-01

    A paradox of memory research is that repeated checking results in a decrease in memory certainty, memory vividness and confidence [van den Hout, M. A., & Kindt, M. (2003a). Phenomenological validity of an OCD-memory model and the remember/know distinction. Behaviour Research and Therapy, 41, 369-378; van den Hout, M. A., & Kindt, M. (2003b). Repeated checking causes memory distrust. Behaviour Research and Therapy, 41, 301-316]. Although these findings have been mainly attributed to changes in episodic long-term memory, it has been suggested [Shimamura, A. P. (2000). Toward a cognitive neuroscience of metacognition. Consciousness and Cognition, 9, 313-323] that representations in working memory could already suffer from detrimental checking. In two experiments we set out to test this hypothesis by employing a delayed-match-to-sample working memory task. Letters had to be remembered in their correct locations, a task that was designed to engage the episodic short-term buffer of working memory [Baddeley, A. D. (2000). The episodic buffer: a new component in working memory? Trends in Cognitive Sciences, 4, 417-423]. Of most importance, we introduced an intermediate distractor question that was prone to induce frustrating and unnecessary checking on trials where no correct answer was possible. Reaction times and confidence ratings on the actual memory test of these trials confirmed the success of this manipulation. Most importantly, high checkers [cf. VOCI; Thordarson, D. S., Radomsky, A. S., Rachman, S., Shafran, R, Sawchuk, C. N., & Hakstian, A. R. (2004). The Vancouver obsessional compulsive inventory (VOCI). Behaviour Research and Therapy, 42(11), 1289-1314] were less accurate than low checkers when frustrating checking was induced, especially if the experimental context actually emphasized the irrelevance of the misleading question. The clinical relevance of this result was substantiated by means of an extreme groups comparison across the two studies. The findings

  19. Poppet valve tester

    Science.gov (United States)

    Tellier, G. F.

    1973-01-01

    Tester investigates fundamental factors affecting cyclic life and sealing performance of valve seats and poppets. Tester provides for varying impact loading of poppet against seat and rate of cycling, and controls amount and type of relative motion between sealing faces of seat and poppet. Relative motion between seat and poppet can be varied in three modes.

  20. BWR control rod drive scram pilot valve monitoring system

    International Nuclear Information System (INIS)

    Soden, R.A.; Kelly, V.

    1984-01-01

    The control rod drive system in a Boiling Water Reactor is the most important safety system in the power plant. All components of the system can be verified except the solenoid operated, scram pilot valves without scramming a rod. The pilot valve mechancial works is the weak link to the control rod drive system. These pilot valves control the hydraulic system which applies pressure to the ''insert'' side of the control rod piston and vents the ''withdraw'' side of the piston causing the rods to insert during a scam. The only verification that the valve is operating properly is to scram the rod. The concern for this portion of the system is demonstrated by the high number of redundant components and complete periodic testing of the electrical circuits. The pilot valve can become hung-up through wear, fracture of internal components, mechanical binding, foreign material or chemicals left in the valve during maintenance, etc. If the valve becomes hung-up the electrical tests performed will not indicate this condition and scramming the rod is in jeopardy. Only an attempt to scram a rod will indicate the hung-up valve. While this condition exists the rod is considered inoperative. This paper describes a system developed at a nuclear power plant that monitors the pilot valves on the control rod drive system. This system utilizes pattern recognition to assure proper internal workings of the scram pilot valves to plant operators. The system is totally automatic such that each time the valve is operated on a ''half scram'', a printout is available to the operator along with light indication that each of the 370 valves (on one unit of a BWR) is operating properly. With this monitoring system installed, all components of the control rod drive system including the solenoid pilot valves can be verified as operational without scramming any rods

  1. BWR control rod drive scram pilot valve monitoring program

    International Nuclear Information System (INIS)

    Soden, R.A.; Kelly, V.

    1986-01-01

    The control rod drive system in a Boiling Water Reactor is the most important safety system in the power plant. All components of the system can be verified except the solenoid operated, scram pilot valves without scramming a rod. The pilot valve mechanical works is the weak link to the control rod drive system. These pilot valves control the hydraulic system which applies pressure to the insert side of the control rod piston and vents the withdraw side of the piston causing the rods to insert during a scram. The only verification that the valve is operating properly is to scram the rod. The concern for this portion of the system is demonstrated by the high number of redundant components and complete periodic testing of the electrical circuits. The pilot valve can become hung-up through wear, fracture of internal components, mechanical binding, foreign material or chemicals left in the valve during maintenance, etc. If the valve becomes hung-up the electrical tests performed will not indicate this condition and scramming the rod is in jeopardy. Only an attempt to scram a rod will indicate the hung-up valve. While this condition exists the rod is considered inoperative. This paper describes a system developed at a nuclear power plant that monitors the pilot valves on the control rod drive system. This system utilizes pattern recognition to assure proper internal workings of the scram pilot valves to plant operators. The system is totally automatic such that each time the valve is operated on a half scram, a printout is available to the operator along with light indication that each of the 370 valves (on one unit of a BWR) is operating properly. With this monitoring system installed, all components of the control rod drive system including the solenoid pilot valves can be verified as operational without scramming any rods

  2. Energy dynamics of the intraventricular vortex after mitral valve surgery.

    Science.gov (United States)

    Nakashima, Kouki; Itatani, Keiichi; Kitamura, Tadashi; Oka, Norihiko; Horai, Tetsuya; Miyazaki, Shohei; Nie, Masaki; Miyaji, Kagami

    2017-09-01

    Mitral valve morphology after mitral valve surgery affects postoperative intraventricular flow patterns and long-term cardiac performance. We visualized ventricular flow by echocardiography vector flow mapping (VFM) to reveal the impact of different mitral valve procedures. Eleven cases of mechanical mitral valve replacement (nine in the anti-anatomical and two in the anatomical position), three bioprosthetic mitral valve replacements, and four mitral valve repairs were evaluated. The mean age at the procedure was 57.4 ± 17.8 year, and the echocardiography VFM in the apical long-axis view was performed 119.9 ± 126.7 months later. Flow energy loss (EL), kinetic pressure (KP), and the flow energy efficiency ratio (EL/KP) were measured. The cases with MVR in the anatomical position and with valve repair had normal vortex directionality ("Clockwise"; N = 6), whereas those with MVR in the anti-anatomical position and with a bioprosthetic mitral valve had the vortex in the opposite direction ("Counterclockwise"; N = 12). During diastole, vortex direction had no effect on EL ("Clockwise": 0.080 ± 0.025 W/m; "Counterclockwise": 0.083 ± 0.048 W/m; P = 0.31) or KP ("Clockwise": 0.117 ± 0.021 N; "Counterclockwise": 0.099 ± 0.057 N; P = 0.023). However, during systole, the EL/KP ratio was significantly higher in the "Counterclockwise" vortex than that in the "Clockwise" vortex (1.056 ± 0.463 vs. 0.617 ± 0.158; P = 0.009). MVP and MVR with a mechanical valve in the anatomical position preserve the physiological vortex, whereas MVR with a mechanical valve in the anti-anatomical position and a bioprosthetic mitral valve generate inefficient vortex flow patterns, resulting in a potential increase in excessive cardiac workload.

  3. First report on a human percutaneous transluminal implantation of a self-expanding valve prosthesis for interventional treatment of aortic valve stenosis.

    Science.gov (United States)

    Grube, Eberhard; Laborde, Jean C; Zickmann, Bernfried; Gerckens, Ulrich; Felderhoff, Thomas; Sauren, Barthel; Bootsveld, Andreas; Buellesfeld, Lutz; Iversen, Stein

    2005-12-01

    Percutaneous aortic valve replacement is a new technology for the treatment of patients with significant aortic valve stenosis. We present the first report on a human implantation of a self-expanding aortic valve prosthesis, which is composed of three bovine pericardial leaflets inserted within a self-expanding nitinol stent. The 73-year-old woman presented with severe symptomatic aortic valve stenosis (mean transvalvular gradient of 45 mmHg; valve area of 0.7 cm2). Surgical valve replacement had been declined for the patient because of comorbidities, including previous bypass surgery. A retrograde approach via the common iliac artery was used for valve deployment. The contralateral femoral vessels were used for a temporary extracorporal circulation, unloading the left ventricle during the actual stent expansion. Clinical, hemodynamic, and echocardiographic outcomes were assessed serially during the procedure. Clinical and echocardiographic follow-up at day 1, 2, and 14 post procedure was performed to evaluate the short-term outcome. The prosthesis was successfully deployed within the native aortic valve, with accurate and stable positioning and with no impairment of the coronary artery or vein graft blood flow. 2D and doppler echo immediately after device deployment showed a significant reduction in transaortic mean pressure gradient (from 45 to 8 mmHg) without evidence of aortic or mitral valve insufficiency. The clinical status has then significantly improved. These results remained unchanged up to the day 14 follow-up. This case report demonstrates a successful percutaneous implantation of a self-expanding aortic valve prosthesis with remarkable functional and clinical improvements in the acute and short-term outcome. Copyright (c) 2005 Wiley-Liss, Inc.

  4. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  5. Radial Force: An Underestimated Parameter in Oversizing Transcatheter Aortic Valve Replacement Prostheses: In Vitro Analysis with Five Commercialized Valves.

    Science.gov (United States)

    Egron, Sandrine; Fujita, Buntaro; Gullón, Lucía; Désirée, Pott; Schmitz-Rode, Thomas; Ensminger, Stephan; Steinseifer, Ulrich

    2017-09-05

    The goal is to inform in depth on transcatheter aortic valve replacement (TAVR) prosthesis mechanical behavior, depending on frame type, design, and size, and how it crucially impacts the oversizing issue in clinical use, and ultimately the procedure outcome. Transcatheter aortic valve replacement is an established therapy for high-risk patients suffering from aortic stenosis, and the indication for TAVR is progressively expanding to intermediate-risk patients. Choosing the optimal oversizing degree is crucial to safely anchor the TAVR valve-which involves limiting the risks for embolism, aortic regurgitation, conductance disturbance, or annulus rupture-and to increase the valve prosthesis performance. The radial force (RF) profiles of five TAVR prostheses were measured in vitro: the CoreValve 23 and 26 (Medtronic, MN), the Acurate neo S (Symetis, Switzerland), and the SAPIEN XT 23 and 26 (Edwards Lifesciences, CA). Measurements were run with the RX Machine equipment (Machine Solutions Inc., AZ), which is used in ISO standard tests for intravascular stents. Test protocols were adapted for TAVR prostheses. With the prostheses RF profiles' results, mechanical behavior differences could be described and discussed in terms of oversizing strategy and clinical impact for all five valves. Besides, crossing the prostheses' RF profiles with their recommended size windows made the assessment of borderline size cases possible and helped analyze the risks when accurate measurement of patient aortic annulus proves difficult. The prostheses' RF profiles bring new support in clinical decision-making for valve type and size in patients.

  6. Fluid-structure interaction dynamic simulation of spring-loaded pressure relief valves under seismic wave

    Science.gov (United States)

    Lv, Dongwei; Zhang, Jian; Yu, Xinhai

    2018-05-01

    In this paper, a fluid-structure interaction dynamic simulation method of spring-loaded pressure relief valve was established. The dynamic performances of the fluid regions and the stress and strain of the structure regions were calculated at the same time by accurately setting up the contact pairs between the solid parts and the coupling surfaces between the fluid regions and the structure regions. A two way fluid-structure interaction dynamic simulation of a simplified pressure relief valve model was carried out. The influence of vertical sinusoidal seismic waves on the performance of the pressure relief valve was preliminarily investigated by loading sine waves. Under vertical seismic waves, the pressure relief valve will flutter, and the reseating pressure was affected by the amplitude and frequency of the seismic waves. This simulation method of the pressure relief valve under vertical seismic waves can provide effective means for investigating the seismic performances of the valves, and make up for the shortcomings of the experiment.

  7. Surgery of the aortic root: should we go for the valve-sparing root reconstruction or the composite graft-valve replacement is still the first choice of treatment for these patients?

    Directory of Open Access Journals (Sweden)

    Fernando de Azevedo Lamana

    2015-09-01

    Full Text Available AbstractObjective:To compare the results of the root reconstruction with the aortic valve-sparing operation versus composite graftvalve replacement.Methods:From January 2002 to October 2013, 324 patients underwent aortic root reconstruction. They were 263 composite graft-valve replacement and 61 aortic valve-sparing operation (43 reimplantation and 18 remodeling. Twenty-six percent of the patients were NYHA functional class III and IV; 9.6% had Marfan syndrome, and 12% had bicuspid aortic valve. There was a predominance of aneurysms over dissections (81% vs. 19%, with 7% being acute dissections. The complete follow-up of 100% of the patients was performed with median follow-up time of 902 days for patients undergoing composite graft-valve replacement and 1492 for those undergoing aortic valve-sparing operation.Results:In-hospital mortality was 6.7% and 4.9%, respectively for composite graft-valve replacement and aortic valve-sparing operation (ns. During the late follow-up period, there was 0% moderate and 15.4% severe aortic regurgitation, and NYHA functional class I and II were 89.4% and 94%, respectively for composite graft-valve replacement and aortic valve-sparing operation (ns. Root reconstruction with aortic valve-sparing operation showed lower late mortality (P=0.001 and lower bleeding complications (P=0.006. There was no difference for thromboembolism, endocarditis, and need of reoperation.Conclusion:The aortic root reconstruction with preservation of the valve should be the operation being performed for presenting lower late mortality and survival free of bleeding events.

  8. Modeling valve leakage

    International Nuclear Information System (INIS)

    Bell, S.R.; Rohrscheib, R.

    1994-01-01

    The American Society of Mechanical Engineers (ASME) Code requires individual valve leakage testing for Category A valves. Although the U.S. Nuclear Regulatory Commission (USNRC) has recognized that it is more appropriate to test containment isolation valves in groups, as allowed by 10 CFR 50, Appendix J, a utility seeking relief from these Code requirements must provide technical justification for the relief and establish a conservative alternate acceptance criteria. In order to provide technical justification for group testing of containment isolation valves, Illinois Power developed a calculation (model) for determining the size of a leakage pathway in a valve disc or seat for a given leakage rate. The model was verified experimentally by machining leakage pathways of known size and then measuring the leakage and comparing this value to the calculated value. For the range of values typical of leakage rate testing, the correlation between the experimental values and calculated values was quote good. Based upon these results, Illinois Power established a conservative acceptance criteria for all valves in the inservice testing (IST) program and was granted relief by the USNRC from the individual leakage testing requirements of the ASME Code. This paper presents the results of Illinois Power's work in the area of valve leakage rate testing

  9. The Effects of Check-In, Check-Up, Check-Out for Students with Moderate Intellectual Disability during On- and Off-Site Vocational Training

    Science.gov (United States)

    Boden, Lauren J.; Jolivette, Kristine; Alberto, Paul A.

    2018-01-01

    Check-in/check-out is a secondary-tier intervention within the positive behavior interventions and supports framework. Check-in/check-out pairs the use of an adult mentor with a daily progress report to help students meet individualized behavioral goals. This study adds to the research base by examining the effects of check-in, check-up, check-out…

  10. Multiple-port valve

    International Nuclear Information System (INIS)

    Doody, T.J.

    1978-01-01

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable with one or more of a plurality of secondary conduits fitting into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits

  11. Nuclear reactor steam depressurization valve

    International Nuclear Information System (INIS)

    Moore, G.L.

    1991-01-01

    This patent describes improvement in a nuclear reactor plant, an improved steam depressurization valve positioned intermediate along a steam discharge pipe for controlling the venting of steam pressure from the reactor through the pipe. The improvement comprises: a housing including a domed cover forming a chamber and having a partition plate dividing the chamber into a fluid pressure activation compartment and a steam flow control compartment, the valve housing being provided with an inlet connection and an outlet connection in the steam flow control compartment, and a fluid duct in communication with a source of fluid pressure for operating the valve; a valve set mounted within the fluid flow control compartment comprising a cylindrical section surrounding the inlet connection with one end adjoining the connection and having a radially projecting flange at the other end with a contoured extended valve sealing flange provided with an annular valve sealing member, and a valve cylinder traversing the partition plate and reciprocally movable within an opening in the partition plate with one terminal and extending into the fluid pressure activation compartment and the other terminal end extending into the steam flow control compartment coaxially aligned with the valve seat surrounding the inlet connection, the valve cylinder being surrounded by two bellow fluid seals and provided with guides to inhibit lateral movement, an end of the valve cylinder extending into the fluid flow control compartment having a radially projecting flange substantially conterminous with the valve seat flange and having a contoured surface facing and complimentary to the contoured valve seating surface whereby the two contoured valve surfaces can meet in matching relationship, thus providing a pressure actuated reciprocatable valve member for making closing contact with the valve seat and withdrawing therefrom for opening fluid flow through the valve

  12. Modal-Based Design Improvement of a Butterfly Valve Disc

    Directory of Open Access Journals (Sweden)

    Marius Draghiciu

    2017-11-01

    Full Text Available The dynamic behaviour control of a butterfly valve is important because, when one of the valve disc natural frequency is close to the frequency of vortex shedding, which appears when the valve is fully open or partially closed, resonance may appear and vibration with significant amplitudes is generated. This paper presents an example by how the design of a butterfly valve disc can be improved by using a modal analysis performed by means of the finite element method. For this purpose, the research reveals the way in which the natural frequencies of the disc can be modified by applying stiffening ribs or changing the dimensions, respective the position of these ribs.

  13. Redo mitral valve surgery

    Directory of Open Access Journals (Sweden)

    Redoy Ranjan

    2018-03-01

    Full Text Available This study is based on the findings of a single surgeon’s practice of mitral valve replacement of 167 patients from April 2005 to June 2017 who developed symptomatic mitral restenosis after closed or open mitral commisurotomy. Both clinical and color doppler echocardiographic data of peri-operative and six months follow-up period were evaluated and compared to assess the early outcome of the redo mitral valve surgery. With male-female ratio of 1: 2.2 and after a duration of 6 to 22 years symptom free interval between the redo procedures, the selected patients with mitral valve restenosis undergone valve replacement with either mechanical valve in 62% cases and also tissue valve in 38% cases. Particular emphasis was given to separate the adhered pericardium from the heart completely to ameliorate base to apex and global contraction of the heart. Besides favorable post-operative clinical outcome, the echocardiographic findings were also encouraging as there was statistically significant increase in the mitral valve area and ejection fraction with significant decrease in the left atrial diameter, pressure gradient across the mitral valve and pulmonary artery systolic pressure. Therefore, in case of inevitable mitral restenosis after closed or open commisurotomy, mitral valve replacement is a promising treatment modality.

  14. Double-disc gate valve

    International Nuclear Information System (INIS)

    Wheatley, S.J.

    1979-01-01

    The invention relates to an improvement in a conventional double-disc gate valve having a vertically movable gate assembly including a wedge, spreaders slidably engaged therewith, a valve disc carried by the spreaders. When the gate assembly is lowered to a selected point in the valve casing, the valve discs are moved transversely outward to close inlet and outlet ports in the casing. The valve includes hold-down means for guiding the disc-and-spreader assemblies as they are moved transversely outward and inward. If such valves are operated at relatively high differential pressures, they sometimes jam during opening. Such jamming has been a problem for many years in gate valves used in gaseous diffusion plants for the separation of uranium isotopes. The invention is based on the finding that the above-mentioned jamming results when the outlet disc tilts about its horizontal axis in a certain way during opening of the valve. In accordance with the invention, tilting of the outlet disc is maintained at a tolerable value by providing the disc with a rigid downwardly extending member and by providing the casing with a stop for limiting inward arcuate movement of the member to a preselected value during opening of the valve

  15. Developments in mechanical heart valve prosthesis

    Indian Academy of Sciences (India)

    M. Senthilkumar (Newgen Imaging) 1461 1996 Oct 15 13:05:22

    BHUVANESHWAR. Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences. & Technology ... affect the performance of mechanical heart valves. The clinical performance of ... those who cannot be put under anticoagulant therapy, like women who may still wish to bear children, or hemolytic patients.

  16. Intro to Valve Guide Reconditioning. Automotive Mechanics. Valves. Instructor's Guide [and] Student Guide.

    Science.gov (United States)

    Horner, W.

    This instructional package, one in a series of individualized instructional units on tools and techniques for repairing worn valve guides in motor vehicles, provides practical experience for students in working on cylinder heads. Covered in the module are reaming valve guides that are oversized to match a new oversized valve, reaming valve guides…

  17. Direct transcatheter aortic valve implantation with self-expandable bioprosthesis: Feasibility and safety

    Energy Technology Data Exchange (ETDEWEB)

    Fiorina, Claudia, E-mail: clafiorina@yahoo.it [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Maffeo, Diego; Curello, Salvatore [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Lipartiti, Felicia [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Chizzola, Giuliano [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); D' Aloia, Antonio [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Adamo, Marianna [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Mastropierro, Rosy [Division of Cardiothoracic Anestesiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Gavazzi, Emanuele [Department of Radiology, University of Brescia, Spedali Civili, Brescia (Italy); Ciccarese, Camilla; Chiari, Ermanna [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Ettori, Federica [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy)

    2014-06-15

    Background: Balloon valvuloplasty has been considered a mandatory step of the transcatheter aortic valve implantation (TAVI), although it is not without risk. The aim of this work was to evaluate the feasibility and safety of TAVI performed without pre-dilation (direct TAVI) of the stenosed aortic valve. Material and Methods: Between June 2012 and June 2013, 55 consecutive TAVI performed without pre-dilation at our institution using the self-expandable CoreValve prosthesis (Medtronic, Minneapolis, MN) were analyzed and compared with 45 pre-dilated TAVI performed the previous year. Inclusion criteria were a symptomatic and severe aortic stenosis. Exclusion criteria were defined as presence of pure aortic regurgitation, degenerated surgical bioprosthesis or bicuspid aortic valve and prior procedure of balloon aortic valvuloplasty performed as a bridge to TAVI. Results: High-burden calcification in the device landing zone, assessed by CT scan, was found in most of the patients. The valve size implanted was similar in both groups. Device success was higher in direct TAVI (85% vs. 64%, p = 0.014), mostly driven by a significant lower incidence of paravalvular leak (PVL ≥2; 9% vs. 33%, p = 0.02). Safety combined end point at 30 days was similar in both groups. Conclusion: Compared to TAVI with pre-dilation, direct TAVI is feasible regardless of the presence of bulky calcified aortic valve and the valve size implanted. Device success was higher in direct TAVI, mostly driven by a lower incidence of paravalvular leak. Safety at 30 days was similar in two groups.

  18. Regular health checks

    DEFF Research Database (Denmark)

    Grønhøj Larsen, Christian; Jørgensen, Karsten Juhl; Gøtzsche, Peter C

    2012-01-01

    To investigate whether Danish providers of general health checks present a balanced account of possible benefits and harms on their websites and whether the health checks are evidence-based.......To investigate whether Danish providers of general health checks present a balanced account of possible benefits and harms on their websites and whether the health checks are evidence-based....

  19. Guide to prosthetic cardiac valves

    International Nuclear Information System (INIS)

    Morse, D.; Steiner, R.M.; Fernandez, J.

    1985-01-01

    This book contains 10 chapters. Some of the chapter titles are: The development of artificial heart valves: Introduction and historical perspective; The radiology of prosthetic heart valves; The evaluation of patients for prosthetic valve implantation; Pathology of cardiac valve replacement; and Bioengineering of mechanical and biological heart valve substitutes

  20. Application of artificial intelligence to motor operated valve testing

    International Nuclear Information System (INIS)

    Bogard, T.; Bednar, F.; Matty, T.; Kent, R.

    1989-01-01

    Improper valve maintenance can be a significant roadblock to successful power plant operation. There have been events during which motor operated valves failed on demand due to improper switch settings. For nuclear electric generating stations, these events have led to regulatory requirements such as NRC Bulletin 85-03 and NRC Bulletin 89-10 Safety Related Motor Operated Valve Testing and Surveillance which imposes strict testing and programmatic requirements on motor operated valves (MOV). Part of the requirements include performing diagnostic testing to verify stem thrust loads and switch settings. Diagnostic equipment must be non-intrusive, minimize valve disassembly, and reduce plant refueling critical path time for testing. In this paper an on-line diagnostic system using sensors to measure stem forces, motor current, and valve position, and a portable system employing these same sensor inputs in addition to torque, limit and torque bypass switch inputs is described. Sophisticated graphic software is employed to display data or trace information. A rule based artificial intelligence (AI) system is used to analyze sensor outputs. Objectives for valve diagnostics, sample AI rules, results of actual field testing, and system software/hardware architecture are presented

  1. [Periodontal microbiota and microorganisms isolated from heart valves in patients undergoing valve replacement surgery in a clinic in Cali, Colombia].

    Science.gov (United States)

    Moreno, Sandra; Parra, Beatriz; Botero, Javier E; Moreno, Freddy; Vásquez, Daniel; Fernández, Hugo; Alba, Sandra; Gallego, Sara; Castillo, Gilberto; Contreras, Adolfo

    2017-12-01

    Periodontitis is an infectious disease that affects the support tissue of the teeth and it is associated with different systemic diseases, including cardiovascular disease. Microbiological studies facilitate the detection of microorganisms from subgingival and cardiovascular samples. To describe the cultivable periodontal microbiota and the presence of microorganisms in heart valves from patients undergoing valve replacement surgery in a clinic in Cali. We analyzed 30 subgingival and valvular tissue samples by means of two-phase culture medium, supplemented blood agar and trypticase soy agar with antibiotics. Conventional PCR was performed on samples of valve tissue. The periodontal pathogens isolated from periodontal pockets were: Fusobacterium nucleatum (50%), Prevotella intermedia/ nigrescens (40%), Campylobacter rectus (40%), Eikenella corrodens (36.7%), Gram negative enteric bacilli (36.7%), Porphyromonas gingivalis (33.3%), and Eubacterium spp. (33.3%). The pathogens isolated from the aortic valve were Propionibacterium acnes (12%), Gram negative enteric bacilli (8%), Bacteroides merdae (4%), and Clostridium bifermentans (4%), and from the mitral valve we isolated P. acnes and Clostridium beijerinckii. Conventional PCR did not return positive results for oral pathogens and bacterial DNA was detected only in two samples. Periodontal microbiota of patients undergoing surgery for heart valve replacement consisted of species of Gram-negative bacteria that have been associated with infections in extraoral tissues. However, there is no evidence of the presence of periodontal pathogens in valve tissue, because even though there were valve and subgingival samples positive for Gram-negative enteric bacilli, it is not possible to maintain they corresponded to the same phylogenetic origin.

  2. Early clinical outcome of aortic transcatheter valve-in-valve implantation in the Nordic countries

    DEFF Research Database (Denmark)

    Ihlberg, Leo; Nissen, Henrik Hoffmann; Nielsen, Niels Erik

    2013-01-01

    Transcatheter valve-in-valve implantation has emerged as an option, in addition to reoperative surgical aortic valve replacement, to treat failed biologic heart valve substitutes. However, the clinical experience with this approach is still limited. We report the comprehensive experience...

  3. Proceedings of EPRI/DOE workshop on nuclear industry valve problems

    International Nuclear Information System (INIS)

    Sprung, J.L.

    1981-01-01

    Representatives from 29 nuclear industry organizations (11 valve manufacturers, 4 nuclear steam supply system vendors, 5 utilities, 3 national laboratories, 2 architect/engineering firms, the Department of Energy (DOE), EPRI, and 2 others) attended the workshop. Working sessions on key valves and on valve stem and seat leakage developed the following recommendations: (1) establish a small permanent expert staff to collect, analyze, and disseminate information about nuclear valve problems; (2) perform generic key valve programs for pressurized water reactors and for boiling water reactors, and several plant specific key valve programs, the latter to demonstrate the cost-effectiveness of such studies; (3) confirm the identity of, define, and initiate needed longer term research and development programs dealing with seat and stem leakage; and (4) establish an industry working group to review and advise on these efforts. Separate abstracts were prepared for three papers which are included in the appendix

  4. Long-Term Outcome of the Sorin Freedom SOLO Stentless Aortic Valve.

    Science.gov (United States)

    Christ, Torsten; Claus, Benjamin; Zielinski, Christina; Falk, Volkmar; Grubitzsch, Herko

    2016-11-01

    The Sorin Freedom SOLO valve is a third-generation stentless aortic valve which shows beneficial hemodynamic performance compared to stented bioprostheses. Long-term results regarding hemodynamics, the durability of the valve, and patient outcome are scarce, and their acquisition was the aim of this single-center study. Between 2005 and 2006, a total of 68 consecutive patients (30 males, 38 females; mean age at surgery 76.1 ± 6.3 years) underwent aortic valve replacement with a Sorin Freedom SOLO prosthesis. Indications were aortic stenosis (n = 50), aortic regurgitation (n = 1) and mixed lesions (n = 17). Associated procedures were performed in 31 patients (45.6%), most of which were coronary artery bypass grafting (68.8 %). The follow up was performed by telephone interviews, and clinical and echocardiographic examinations. Morbidity, mortality and echocardiographic data were analyzed. The total follow up was 501.1 patient-years, with a mean follow up of 7.4 ± 3.4 years (maximum 11.2 years). The follow up was 100% complete. Hospital mortality was 4.4% (n = 3). Actuarial survival at five and 10 years was 76.5 ± 5.1% and 41.5 ± 6.5%, respectively. Reinterventions were performed in eight patients; these included three reoperations due to endocarditis, four transcatheter aortic valve implantations, and one reoperation due to structural valve deterioration (SVD). The overall freedom from valve reintervention due to SVD at five and 10 years was 97.8 ± 2.2% and 82.9 ± 7.5%, respectively. After eight years, echocardiography demonstrated peak and mean transvalvular gradients of 18 ± 11 and 10 ± 7 mmHg, respectively. The overall effective and indexed aortic valve orifice areas were 1.73 ± 0.58 cm2 and 0.92 ± 0.33 cm2/m2, respectively. At long-term follow up the Sorin Freedom SOLO bioprosthesis was associated with favourable hemodynamic results and survival. Freedom from SVD was not superior to that occurring with stented bioprostheses.

  5. Checking Java Programs

    CERN Document Server

    Darwin, Ian

    2007-01-01

    This Short Cut tells you about tools that will improve the quality of your Java code, using checking above and beyond what the standard tools do, including: Using javac options, JUnit and assertions Making your IDE work harder Checking your source code with PMD Checking your compiled code (.class files) with FindBugs Checking your program's run-time behavior with Java PathFinder

  6. Degenerative processes in bioprosthetic mitral valves in juvenile pigs

    Directory of Open Access Journals (Sweden)

    Pedersen Torben B

    2011-05-01

    Full Text Available Abstract Background Glutaraldehyde-treated bioprosthetic heart valves are commonly used for replacement of diseased heart valves. However, calcification and wear limit their durability, and the development of new and improved bioprosthetic valve designs is needed and must be evaluated in a reliable animal model. We studied glutaraldehyde-treated valves 6 months after implantation to evaluate bioprosthetic valve complications in the mitral position in juvenile pigs. Materials The study material comprised eight, 5-month old, 60-kg pigs. All pigs received a size 27, glutaraldehyde-treated, stented, Carpentier-Edwards S.A.V. mitral valve prosthesis. After six months, echocardiography was performed, and the valves explanted for gross examination, high resolution X-ray, and histological evaluation. Results Five pigs survived the follow-up period. Preexplant echocardiography revealed a median peak and mean velocity of 1.61 m/s (range: 1.17-2.00 and 1.20 (SD = ±0.25, respectively, and a median peak and mean pressure difference of 10.42 mmHg (range: 5.83-16.55 and 6.51 mmHg (SD = ±2.57, respectively. Gross examination showed minor thrombotic depositions at two commissures in two valves and at all three commissures in three valves. High resolution X-ray imaging revealed different degrees of calcification in all explanted valves, primarily in the commissural and belly areas. In all valves, histological evaluation demonstrated various degrees of fibrous sheath formation, limited immunological infiltration, and no overgrowth of host endothelium. Conclusions Bioprosthetic glutaraldehyde-treated mitral valves can be implanted into the mitral position in pigs and function after 6 months. Echocardiographic data, calcification, and histological examinations were comparable to results obtained in sheep models and human demonstrating the suitability of the porcine model.

  7. Nuclear valves latest development

    International Nuclear Information System (INIS)

    Isaac, F.; Monier, M.

    1993-01-01

    In the frame of Nuclear Power Plant upgrade (Emergency Power Supply and Emergency Core Cooling), Westinghouse had to face a new valve design philosophy specially for motor operated valves. The valves have to been designed to resist any operating conditions, postulated accident or loss of control. The requirements for motor operated valves are listed and the selected model and related upgrading explained. As part of plant upgrade and valves replacement, Westinghouse has sponsored alternative hardfacing research programme. Two types of materials have been investigated: nickel base alloys and iron base alloys. Programme requirements and test results are given. A new globe valve model (On-Off or regulating) is described developed by Alsthom Velan permitting the seat replacement in less than 10 min. (Z.S.) 2 figs

  8. Enhancement of pressurizer safety valve operability by seating design improvement

    International Nuclear Information System (INIS)

    Moisidis, N.T.; Ratiu, M.D.

    1994-01-01

    Operating conditions specific to Pressurizer Safety Valves (PSVs) have led to numerous problems and have caused industry and NRC concerns regarding the adequacy of spring loaded self-actuated safety valves for Reactor Coolant System (RCS) overpressure protection. Specific concerns are: setpoint drift, spurious actuations and leakage. Based on testing and valve construction analysis of a Crosby model 6M6 PSV, it was established that the primary contributor to the valve problems is a susceptibility to weak seating. To eliminate spring instability, a new spring washer was designed, which guides the spring and precludes its rotation from the reference installed position. Results of tests performed on a prototype PSV equipped with the modified upper spring washer has shown significant improvements in valve operability and a consistent setpoint reproducibility to less than ±1% of the PSV setpoint (testing of baseline, unmodified valve, resulted in a setpoint drift of ±2%). Enhanced valve operability will result in a significant decrease in operating and maintenance costs associated with valve maintenance and testing. In addition, the enhanced setpoint reproducibility will allow the development of a nitrogen to steam correlation for future in-house PSV testing which will result in further reductions in costs associated with valve testing

  9. Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis

    Directory of Open Access Journals (Sweden)

    Rajesh Janardhanan

    2016-05-01

    Full Text Available In intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Learning objectives: • Early recognition of a mitral valve aneurysm (MVA is important because it may rupture and produce catastrophic mitral regurgitation (MR in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR. • Real-time 3D-transesophageal echocardiography (RT-3DTEE is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA.

  10. Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis.

    Science.gov (United States)

    Janardhanan, Rajesh; Kamal, Muhammad Umar; Riaz, Irbaz Bin; Smith, M Cristy

    2016-03-01

    SummaryIn intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve) endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Early recognition of a mitral valve aneurysm (MVA) is important because it may rupture and produce catastrophic mitral regurgitation (MR) in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR).Real-time 3D-transesophageal echocardiography (RT-3DTEE) is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA. © 2016 The authors.

  11. Seismic qualification of motor operated valves - alternate approach

    International Nuclear Information System (INIS)

    Bruck, P.M.; Eissa, M.A.

    1998-01-01

    This paper presents a potential alternate method for determining operating capacity of motor-operated valves subjected to seismic and other applicable loadings. As a result of programs at nuclear facilities to ensure the operational capability of MOVs (under NRC GL89-10), extensive analytical focus to develop the structural capability of valves has ensued. In the past, seismic qualification of valves typically addressed the strength of the topwork structure to resist inertial loading from excitation of the large valve actuator mass. These evaluations paid little or no consideration to the loading resulting from valve closing forces. The focus of the recent efforts is to develop the maximum operational capability of the valve, in terms of thrust, with consideration of seismic and other services loading as applicable. The alternate method outlined in this paper presents a series of thrust capacity curves, with reduction factors for seismic loading which can be applied and developed to determine safe thrust loadings without performing extensive analytical effort. A similar approach was put forward by the SQUG GIP approach to MOVs to ensure the safe operation of valves based on past earthquake experience. However, the GIP approach cannot be used to determine safe operational loads and thus has limited use in the necessary analysis required for GL89-10 programs at nuclear facilities. (orig.)

  12. Analysis of design parameters and flow characteristics of the vortex valve for SIT flow control

    International Nuclear Information System (INIS)

    Hwang, Young Dong; Chang, Moon Hee; Kim, Seong O.; Kim, Young In.

    1997-01-01

    This study was performed to provide a technical basis for the development of the vortex valve which will be adopted in Korean Advanced Reactor. The influence of nondimensional and geometrical parameters of the vortex valve were investigated by analyzing the flow field of the vortex chamber, and the performance related parameters were evaluated by utilizing of the published experimental and analytical data. Also the level transients of the stand pipe were investigated by using of the simplified analytical model. In order to obtain the more detailed information on the vortex flow field, three dimensional preliminary analyses for the vortex valve design were conducted by FLUENT code. This study were carried out by using the simplified analytical model of the vortex valve and downstream pipe. However, the detailed analysis on the integrated system of the vortex valve with the as built design data and the required operating conditions should be performed to obtain the more accurate results on the vortex valve behavior. Also the experimental study over a wide range of operating conditions to develop the correlation of the design parameters and the performance verification should be performed for the practical design and engineering applications of the vortex valve. The results of this study can be used as a basic information for the development of the vortex valve design for the SIT of Korean Advanced Reactor. (author). 12 refs., 5 tabs., 33 figs

  13. Factors influencing mortality after bioprosthetic valve replacement; a midterm outcome.

    Science.gov (United States)

    Javadzadegan, Hassan; Javadzadegan, Amir; Mehdizadeh Baghbani, Jafar

    2013-01-01

    Although valve repair is applied routinely nowadays, particularly for mitral regurgitation (MR) or tricuspid regurgitation (TR), valve replacement using prosthetic valves is also common especially in adults. Unfortunately the valve with ideal hemodynamic performance and long-term durability without increasing the risk of bleeding due to long-term anticoagulant therapy has not been introduced. Therefore, patients and physicians must choose either bioprosthetic or mechanical valves. Currently, there is an increasing clinical trend of using bioprosthetic valves instead of mechanical valves even in young patients apparently because of their advantages. Seventy patients undergone valvular replacement using bioprosthetic valves were evaluated by ECG and Echocardiography to assess the rhythm and ejection fracture. Mean follow-up time was 33 months (min 9, max 92). Mortality rate was 25.9% (n=18) within 8 years of follow-up. Statistical analysis showed a significant relation between atrial fibrillation rhythm and mortality (P=0.02). Morbidities occurred in 30 patients (42.8%). Significant statistical relation was found between the morbidities and age over 65 years old (P=0.005). In follow-up period, 4 cases (5.7%) underwent re-operation due to global valve dysfunction. Our study shows that using biprosthetic valve could reduce the risk of morbidity occurrence in patient who needs valve replacement. However, if medical treatments fail, patients should be referred for surgery. This would reduce the risk of mortality because of lower incident of complications such as atrial fibrillation and morbidities due to younger patients' population.

  14. [Pannus Formation Two Years after Bioprosthetic Aortic Valve Implantation;Report of a Case].

    Science.gov (United States)

    Ono, Kimiyo; Kuroda, Hiroaki

    2015-08-01

    We report a case of early deterioration of the bioprosthetic aortic valve 23 months postoperatively. A 77-year-old man who had undergone aortic valve replacement with a 23-mm Epic valve( St. Jude Medical [SJM])presented to us after a syncopal episode. Echocardiography revealed severe aortic stenosis, and redo aortic valve replacement with a 21-mm SJM mechanical valve was performed. All 3 cusps of the tissue valve were thickened by fibrous pannus overgrowth. Neither calcification nor invasion of inflammatory cells was observed. The cause of pannus formation at such an early stage after implantation remains unknown.

  15. Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John; Brecker, Stephen

    2012-01-01

    Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry....

  16. Steel castings of valves for nuclear power station

    International Nuclear Information System (INIS)

    Yamasaki, Yutaka

    1975-01-01

    The manufacturing of the steel castings of valves for nuclear power plants is reported. The report is divided in six parts. The first part describes the reliability of the steel castings of valves for nuclear power plants. Particular attention must be paid to larger diameter and lower pressure rating for the valves in nuclear power plants than those in thermal power plants. The second part describes the characteristics of steel casting quality, defects and their cause. The defects that may be produced in steel castings are as follows: (a) cavities caused by the insufficient supply of molten steel, (b) sand bites caused by the mold destruction due to thermal shock, and (c) pinholes caused by the gas absorption of molten steel. The third part describes the clarification of quality level and the measures quality project. Gaseous defects and the indications detected by magnetic powder test are attributed to electric furnace steel making. In particular, the method to minimize gas content is important. The fourth part describes the quality control of manufacturing processes. In practice, thirteen semi-automatic testers using gamma radiation are employed. A full automatic inspection plant having capacity of 20,000 radiographs per month is under design. The fifth part describes a quality warrant system. A check sheet system concerning quality and safety is employed in all work shops. The reliability of all testers and measuring instruments as well as the skill of workmen are examined periodically. The seventh part deals with future problems. The manufacturing plan must be controlled so that non-destructive inspection becomes the main means for quality control. (Iwakiri, K.)

  17. Unicuspid aortic valve disease: a magnetic resonance imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Debl, K.; Buchner, S.; Heinicke, N.; Riegger, G.; Luchner, A. [Klinik und Poliklinik fuer Innere Medizin II, Universitaetsklinikum Regensburg (Germany); Djavidani, B.; Poschenrieder, F.; Feuerbach, S. [Inst. fuer Roentgendiagnostik, Universitaetsklinikum Regensburg (Germany); Schmid, C.; Kobuch, R. [Klinik und Poliklinik fuer Herz-, Thorax- und herznahe Gefaesschirurgie, Universitaetsklinikum Regensburg (Germany)

    2008-11-15

    Purpose: congenitally malformed aortic valves are a common finding in adults with aortic valve disease. Most of these patients have bicuspid aortic valve disease. Unicuspid aortic valve disease (UAV) is rare. The aim of our study was to describe valve morphology and the dimensions of the proximal aorta in a cohort of 12 patients with UAV in comparison to tricuspid aortic valve disease (TAV) using magnetic resonance imaging (MRI). Materials and methods/results: MRI studies were performed on a 1.5 T scanner in a total of 288 consecutive patients with aortic valve disease. 12 aortic valves were retrospectively classified as UAV. Annulus areas and dimensions of the thoracic aorta were retrospectively compared to a cohort of 103 patients with TAV. In UAV, valve morphology was unicuspid unicommissural with a posterior commissure in all patients. Mean annulus areas and mean diameters of the ascending aorta were significantly greater in UAV compared to TAV (12.6 {+-} 4.7 cm{sup 2} vs. 8.7 {+-} 2.3 cm{sup 2}, p < 0.01 and 4.6 {+-} 0.7 cm vs. 3.6 {+-} 0.5 cm, p < 0.0001, respectively), while no differences were observed in the mean diameters of the aortic arch (2.3 {+-} 0.6 cm vs. 2.3 {+-} 0.4 cm, p = 0.69). The diameters of the descending aorta were slightly smaller in UAV compared to TAV (2.2 {+-} 0.5 cm vs. 2.6 {+-} 0.3 cm, p < 0.05). (orig.)

  18. Transcatheter aortic valve replacement

    Science.gov (United States)

    ... gov/ency/article/007684.htm Transcatheter aortic valve replacement To use the sharing features on this page, please enable JavaScript. Transcatheter aortic valve replacement (TAVR) is surgery to replace the aortic valve. ...

  19. Designing innovative retractors and devices to facilitate mitral valve repair surgery

    OpenAIRE

    Okamoto, Kazuma; Yozu, Ryohei

    2015-01-01

    Various devices have been developed to facilitate mitral valve surgery, including those that improve mitral valve exposure and assist surgeons with associated procedures. Choosing appropriate supporting devices when performing minimally invasive mitral valve surgery (MIMVS) through a minithoracotomy with endoscopic assistance is critical. Depending on the surgeon’s preference, trans-thoracic or trans-working-port left atrial retractors can be utilized. Although the trans-thoracic retractors p...

  20. Overflow control valve

    International Nuclear Information System (INIS)

    Kessinger, B.A.; Hundal, R.; Parlak, E.A.

    1982-01-01

    An overflow control valve for use in a liquid sodium coolant pump tank which can be remotely engaged with and disengaged from the pump tank wall to thereby permit valve removal. An actuating shaft for controlling the valve also has means for operating a sliding cylinder against a spring to retract the cylinder from sealing contact with the pump tank nozzle. (author)

  1. Effect of amusement park rides on programmable shunt valve settings.

    Science.gov (United States)

    Strahle, Jennifer; Collins, Kelly; Stetler, William R; Smith, Brandon W; Garton, Thomas; Garton, Catherine; Garton, Hugh J L; Maher, Cormac O

    2013-01-01

    Magnetically programmable shunt valves are susceptible to environmental factors including magnetic fields and accelerative forces. It is unknown if rollercoasters with or without magnetic brakes or linear induction motors (LIMs) are capable of altering the setting of a programmable shunt valve. Two different valve types (type A, n = 10; type B, n = 9) were tested at varying resistance settings in 2 trials on 6 different amusement park rides including 2 rides with LIMs, 2 rides with magnetic brakes, and 2 rides without magnetic technology. The performance level of valve type A and the setting of valve type B changed on rollercoasters with magnets (A = 2.5% [2/80]; B = 5.6% [4/72]) and without magnets (A = 7.5% [3/40]; B = 2.8% [1/36]). Neither valve setting changed when exposed to a Ferris wheel or during ambulation throughout the park. Magnetically programmable valves are susceptible to changes in pressure settings when exposed to amusement park rides with elevated vertical gravitational forces, irrespective of the presence of LIMs or magnetic brakes. © 2013 S. Karger AG, Basel.

  2. The prognosis of infective endocarditis treated with biological valves versus mechanical valves: A meta-analysis.

    Science.gov (United States)

    Tao, Ende; Wan, Li; Wang, WenJun; Luo, YunLong; Zeng, JinFu; Wu, Xia

    2017-01-01

    Surgery remains the primary form of treatment for infective endocarditis (IE). However, it is not clear what type of prosthetic valve provides a better prognosis. We conducted a meta-analysis to compare the prognosis of infective endocarditis treated with biological valves to cases treated with mechanical valves. Pubmed, Embase and Cochrane databases were searched from January 1960 to November 2016.Randomized controlled trials, retrospective cohorts and prospective studies comparing outcomes between biological valve and mechanical valve management for infective endocarditis were analyzed. The Newcastle-Ottawa Scale(NOS) was used to evaluate the quality of the literature and extracted data, and Stata 12.0 software was used for the meta-analysis. A total of 11 publications were included; 10,754 cases were selected, involving 6776 cases of biological valves and 3,978 cases of mechanical valves. The all-cause mortality risk of the biological valve group was higher than that of the mechanical valve group (HR = 1.22, 95% CI 1.03 to 1.44, P = 0.023), as was early mortality (RR = 1.21, 95% CI 1.02 to 1.43, P = 0.033). The recurrence of endocarditis (HR = 1.75, 95% CI 1.26 to 2.42, P = 0.001), as well as the risk of reoperation (HR = 1.79, 95% CI 1.15 to 2.80, P = 0.010) were more likely to occur in the biological valve group. The incidence of postoperative embolism was less in the biological valve group than in the mechanical valve group, but this difference was not statistically significant (RR = 0.90, 95% CI 0.76 to 1.07, P = 0.245). For patients with prosthetic valve endocarditis (PVE), there was no significant difference in survival rates between the biological valve group and the mechanical valve group (HR = 0.91, 95% CI 0.68 to 1.21, P = 0.520). The results of our meta-analysis suggest that mechanical valves can provide a significantly better prognosis in patients with infective endocarditis. There were significant differences in the clinical features of patients

  3. Clinical Implication of Transaortic Mitral Pannus Removal During Repeat Cardiac Surgery for Patients With Mechanical Mitral Valve.

    Science.gov (United States)

    Park, Byungjoon; Sung, Kiick; Park, Pyo Won

    2018-01-25

    This study aimed to evaluate the safety and feasibility of transaortic mitral pannus removal (TMPR).Methods and Results:Between 2004 and 2016, 34 patients (median age, 57 years; 30 women) with rheumatic disease underwent pannus removal on the ventricular side of a mechanical mitral valve through the aortic valve during reoperation. The median time interval from the previous surgery was 14 years. TMPR was performed after removal of the mechanical aortic valve (n=21) or diseased native aortic valve (n=11). TMPR was performed in 2 patients through a normal aortic valve. The mitral transprosthetic mean pressure gradient (TMPG) was ≥5 mmHg in 11 patients, including 3 with prosthetic valve malfunction. Prophylactic TMPR was performed in 23 patients. There were no early deaths. Concomitant operations included 22 tricuspid valve surgeries (13 replacements, 15 repairs) and 32 aortic valve replacements (24 repeats, 8 primary). The mean gradient in patients who had mitral TMPG ≥5 mmHg was significantly decreased from 6.46±1.1 to 4.37±1.17 mmHg at discharge (Ppannus overgrowth in such valves.

  4. Energetic and dynamic impact of counterbalance valves in fluid power machines

    International Nuclear Information System (INIS)

    Ritelli, Guido Francesco; Vacca, Andrea

    2013-01-01

    Highlights: • A graphical method to study the operation of counterbalance valves is presented. • The method is suitable to study the impact of valve settings on energy consumption. • Energetic considerations on a hydraulic crane were performed through numerical simulations. • Test were performed to validate the model on steady-state and transient conditions. • Energy consumption reduction potentials in current applications were discussed. - Abstract: Counterbalance valves negatively affect the dynamical behavior of most of the hydraulic systems in which they are utilized, and they introduce additional energy consumption. Various valve architectures have been developed to address the dynamical issues related to the use of these components, and empirical guidelines are also available to determine the best value of their set parameters such as the pilot ratio and the setting pressure. However, the problem of characterizing the portion of energy consumption introduced by counterbalance valves in a hydraulic circuit, and how this consumption is related to the valve setting, has never been addressed according to a systematic approach. This paper addresses this problem and proposes a general approach to study the energy consumption introduced by the counterbalance valves for given operating cycles of the machine in which they are used. In particular, a graphical method is utilized to study the effects of counterbalance valves in the whole hydraulic system. This method is also used to interpret the potentials for energy recovery associated with different settings of the counterbalance valves. The basic considerations which can be obtained using a graphical method are then supported by results provided by a more detailed numerical model of a particular reference machine, a hydraulic crane. The numerical model is validated on the basis of experimental results and permits to derive not only considerations about the energy consumption of counterbalance valves, but

  5. Transcatheter Pulmonary Valve Replacement: Current State of Art.

    Science.gov (United States)

    Alkashkari, Wail; Alsubei, Amani; Hijazi, Ziyad M

    2018-03-15

    The past couple of decades have brought tremendous advances to the field of pediatric and adult congenital heart disease (CHD). Percutaneous valve interventions are now a cornerstone of not just the congenital cardiologist treating patients with congenital heart disease, but also-and numerically more importantly-for adult interventional cardiologists treating patients with acquired heart valve disease. Transcatheter pulmonary valve replacement (tPVR) is one of the most exciting recent developments in the treatment of CHD and has evolved to become an attractive alternative to surgery in patients with right ventricular outflow tract (RVOT) dysfunction. This review aims to summarize (1) the current state of the art for tPVR, (2) the expanding indications, and (3) the technological obstacles to optimizing tPVR. Since its introduction in 2000, more than ten thousands tPVR procedures have been performed worldwide. Although the indications for tPVR have been adapted earlier from those accepted for surgical intervention, they remain incompletely defined. The new imaging modalities give better assessment of cardiac anatomy and function and determine candidacy for the procedure. The procedure has been shown to be feasible and safe when performed in patients who received pulmonary conduit and or bioprosthetic valves between the right ventricle and the pulmonary artery. Fewer selected patients post trans-annular patch repair for tetralogy of Fallot may also be candidates for this technology. Size restrictions of the currently available valves limit deployment in the majority of patients post trans-annular patch repair. Newer valves and techniques are being developed that may help such patients. Refinements and further developments of this procedure hold promise for the extension of this technology to other patient populations.

  6. NRC perspective and experience on valve testing

    International Nuclear Information System (INIS)

    Eapen, P.K.

    1990-01-01

    Testing of safety related valves is one of the major activities at commercial nuclear power plants. In addition to Technical Specification, valve testing is required in 10 CFR 50.55a and 10 CFR 50 Appendix J. NRC inspectors (both resident and specialists) spend a considerable amount of time in following the valve test activities as part of their routine business. In the past, depending on a licensee's organizational structure, a valve could be tested more than three times to verify conformance with Technical Specifications, 10 CFR 50.55a, and 10 CFR 50 Appendix J. The regulatory reviewers were isolated from each other. Licensee test personnel were also not communicating among themselves. As a result, NRC inspectors found that certain valves in the IST program were inadequately tested. The typical licensee response was to say that this valve is exempted from testing under Appendix J. Others would say that the technical specification does not require fast closure of a valve in question. In addition to the above, the inspectors had to deal with exemption requests that were not dispositioned by the NRC. In the seventies there was a gentlemen's agreement to allow the licensee to do the testing in accordance with the exception, without waiting for the NRC approval. Needless to say when the new NRC inspection procedure was issued in March 1989 for implementation, the Regional inspectors had extremely difficult time to cope with the gray areas of valve testing. In August 1987, NRC Region I was reorganized and the special test program section was established to perform inspections in the IST area. This section was chartered to optimize resources and develop a meaningful inspection plan. The perspectives and insights used in the development of a detailed inspection plan is discussed below

  7. Intelligent Flow Control Valve

    Science.gov (United States)

    Kelley, Anthony R (Inventor)

    2015-01-01

    The present invention is an intelligent flow control valve which may be inserted into the flow coming out of a pipe and activated to provide a method to stop, measure, and meter flow coming from the open or possibly broken pipe. The intelligent flow control valve may be used to stop the flow while repairs are made. Once repairs have been made, the valve may be removed or used as a control valve to meter the amount of flow from inside the pipe. With the addition of instrumentation, the valve may also be used as a variable area flow meter and flow controller programmed based upon flowing conditions. With robotic additions, the valve may be configured to crawl into a desired pipe location, anchor itself, and activate flow control or metering remotely.

  8. Combined PCI and minimally invasive heart valve surgery for high-risk patients.

    Science.gov (United States)

    Umakanthan, Ramanan; Leacche, Marzia; Petracek, Michael R; Zhao, David X; Byrne, John G

    2009-12-01

    Combined coronary artery valvular heart disease is a major cause of morbidity and mortality in the adult patient population. The standard treatment for such disease has been open heart surgery in which coronary artery bypass grafting (CABG) is performed concurrently with valve surgery using a median sternotomy and cardiopulmonary bypass. With the increasing complexity of patients referred to surgery, some patients may prove to be poor surgical candidates for combined valve and CABG surgery. In certain selected patients who fall into this category, valve surgery and percutaneous coronary intervention (PCI) have been considered a feasible alternative. Conventionally, valve surgery is performed in the cardiac surgical operating room, whereas PCI is carried out in the cardiac catheterization laboratory. Separation of these two procedural suites has presented a logistic limitation because it impedes the concomitant performance of both procedures in one setting. Hence, PCI and valve surgery usually have been performed as a "two-stage" procedure in two different operative suites, with the procedures being separated by hours, days, or weeks. Technologic advancements have made possible the construction of a "hybrid" procedural suite that combines the facilities of a cardiac surgical operating room with those of a cardiac catheterization laboratory. This design has enabled the concept of "one-stage" or "one-stop" PCI and valve surgery, allowing both procedures to be performed in a hybrid suite in one setting, separated by minutes. The advantages of such a method could prove to be multifold by enabling a less invasive surgical approach and improving logistics, patient satisfaction, and outcomes in selected patients.

  9. Midterm Results of Aortic Valve Replacement with Cryopreserved Homografts

    Directory of Open Access Journals (Sweden)

    Emre Özker

    2012-06-01

    Full Text Available Objective: The aim of this study was to analyze the midterm clinical results of aortic valve replacement with cryopreserved homografts.Materials and Methods: Aortic valve replacement was performed in 40 patients with cryopreserved homograft. The indications were aortic valve endocarditis in 20 patients (50%, truncus arteriosus in 6 patients (15%, and re-stenosis or regurtitation after aortic valve reconstruction in 14 (35% patients. The valve sizes ranged from 10 to 27mm. A full root replacement technique was used for homograft replacement in all patients.Results: The 30-day postoperative mortality rate was 12.5% (5 patients. There were four late deaths. Only one of them was related to cardiac events. Overall mortality was 22.5%. Thirty-three patients were followed up for 67±26 months. Two patients needed reoperation due to aortic aneurysm caused by endocarditis. The mean transvalvular gradient significantly decreased after valve replacement (p<0.003. The last follow up showed that the 27 (82% patients had a normal left ventricular function.Conclusion: Cryopreserved homografts are safe alternatives to mechanical valves that can be used when there are proper indications. Although it has a high perioperative mortality rate, cryopreserved homograft implantation is an alternative for valve replacement, particularly in younger patients and for complex surgical problems such as endocarditis that must be minimalized.

  10. Tests for the dynamic behavior of insulation valve screws

    International Nuclear Information System (INIS)

    Tulke, K.D.; Stoppler, W.; Stern, G.

    1994-01-01

    Thermal tensile tests were performed at a temperature of 270 C, with two new original insulation valve conical screws M30-Tx92,5 mm (material: 21 CrMo V 5 7)and two prestrained ones during the event on 27.12.92. In order to assure the results obtained with regard to the dynamic load on the insulation valve during ''quick opening'', in addition tensile impact tests were performed at 270 C with six original insulation valve conical screws. Impact velocity reached 13,5 m/s at four screws and 6 m/s at two screws. Test conditions regarding collision damping and mass distribution were adapted, by means of parameter studies, to the situation of the insulation valve. During thermal tensile tests, strength and deformation values, such as stress at flow start, tensile strength, fracture prolongation and strain, necking at fracture as well as energy absorption up to maximum force and up to rupture, were determined. During tensile impact tests, deformation values, such as elongation, strain and necking, and energy absorption by the screw, were determined. (orig.) [de

  11. Radiotherapy-induced aortic valve disease associated with porcelain aorta

    International Nuclear Information System (INIS)

    Daitoku, Kazuyuki; Fukui, Kozo; Ichinoseki, Ikkoh; Munakata, Mamoru; Takahashi, Shoichi; Fukuda Ikuo

    2004-01-01

    Mediastinal irradiation has been reported to induce cardiac disease such as pericarditis, valvular dysfunction, conduction abnormalities, accelerated arteriosclerosis of the coronary arteries, and also calcifications of the ascending aorta. We herein describe a case of radiotherapy-induced porcelain aorta and aortic valve disease and their surgical treatment. The patient was diagnosed with myasthenia gravis (MG) in 1965 (Osserman's type II), and mediastinal irradiation was performed in 1970 for treatment of thymic tumor associated with MG. Thirty years after radiation therapy, complete atrioventricular block and aortic valve disease with severe calcification of the ascending aorta and aortic arch (porcelain aorta) were detected on echo cardiogram and cardiac catheterization. A permanent pacemaker was implanted via the left subclavian vein and aortic valve replacement was performed under extracorporeal circulation established by selective cerebral perfusion and balloon occlusion instead of aortic cross-clamping. As no risk factors of arteriosclerosis such as hypercholesterolemia, hyperglycemia and hypertension were apparent, we concluded that the aortic valve disease and porcelain aorta were primarily induced by radiotherapy. (author)

  12. What caused the failures of the solenoid valve screws

    International Nuclear Information System (INIS)

    Vassallo, T.P.; Mumford, J.R.; Hossain, F.

    2001-01-01

    At Seabrook Station on May 5,1998 following a lengthy purge of the pressurizer steam space through Containment isolation sample valve 1-RC-FV-2830, the UL status light associated with this solenoid valve did not come on when the valve was closed from the plant's main control board. The UL status light is used to confirm valve closure position to satisfy the plant's Technical Specification requirements. The incorrect valve position indication on the main control board was initially believed to have resulted from excessive heat from a failed voltage control module that did not reduce the voltage to the valve's solenoid coil. This conclusion was based on a similar event that occurred in November of 1996. Follow-up in-plant testing of the valve determined that the voltage control module had not failed and was functioning satisfactorily. Subsequent investigations determined the root cause of the event to be excessive heat-up of the valve caused by high process fluid temperature and an excessively long purge of the pressurizer. The excessive heat-up of the valve from the high temperature process fluid weakened the magnetic field strength of the valve stem magnet to the extent that the UL status light reed switch would not actuate when the valve was closed. Since the voltage control module was tested and found to be functioning properly it was not replaced. Only the UL status light reed switch was replaced with a more sensitive reed that would respond better to a reduced magnetic field strength that results from a hot magnet. During reed switch replacement, three terminal block screws in the valve housing were found fractured and three other terminal block screws fractured during determination of the electrical conductors. This paper describes the initial plant event and ensuing laboratory tests and examinations that were performed to determine the root cause of the failure of the terminal block screws from the Containment isolation sample solenoid valve. (author)

  13. Hemodynamics in the Valsalva sinuses after transcatheter aortic valve implantation (TAVI).

    Science.gov (United States)

    Ducci, Andrea; Tzamtzis, Spyridon; Mullen, Michael J; Burriesci, Gaetano

    2013-09-01

    The study aim was to assess, in vitro, the hemodynamic modifications produced by transcatheter valves in the Valsalva sinuses, by mean of phase-resolved particle image velocimetry (PIV) measurements. Flow measurements were performed on a glass mock aortic root that included three polymeric valve leaflets, before and after the implantation of a Medtronic CoreValve device and of an Edwards SAPIEN valve. All experiments were carried out in a hydro-mechanical cardiovascular pulse duplicator system (Vivitro Superpump System SP3891) that reproduced physiologically equivalent pressures and flow rates conforming to the requirements of the standard ISO 5840:2005. The flow dynamics, before and after implantation of the two prosthetic devices, was characterized on the basis of phase-resolved velocity field and viscous shear rate measurements. Direct comparison indicated that both transcatheter valves determined a significant variation of flow during the early stages of valve opening and during valve closure. In general, the presence of the two valve implants significantly reduced the flow activity in the Valsalva sinuses, promoting regions of stagnation at their base. The reduction in flow in the Valsalva sinuses could be associated with the higher incidence of ischemic events reported after transcatheter heart valve implantation.

  14. Micro-fabricated membrane gas valves with a non-stiction coating deposited by C4F8/Ar plasma

    International Nuclear Information System (INIS)

    Han, Jeahyeong; Flachsbart, Bruce; Shannon, Mark A; Masel, Rich I

    2008-01-01

    Micro-fabricated gas valves with C 4 F 8 /Ar treatment at the sealing interface are designed, fabricated and characterized to passively control gases in a micro gas analysis system. The check valves form a seal between a polished Si/SiO 2 substrate and a smooth polyimide (PI) membrane. The smooth PI membrane touches the SiO 2 surface, giving rise to relatively strong van der Waals adhesion, and under humid conditions hydrogen-bonded stiction can occur at the interface between PI and SiO 2 . To prevent stiction from dominating adhesion, the valve-seat surface was treated with a hydrophobic CF n thin film, which was formed by exposing the surface to C 4 F 8 /Ar inductively coupled plasma (ICP) at low power. The valves without a non-stiction coating did not open with inlet pressures up to 210 kPa. With a non-stiction coating, the valves showed an average initial opening pressure of 59.25 kPa. In order to further reduce the opening pressure, 40% of the valve-seat area is reduced. After modification, the average opening pressure is reduced to 32.5 kPa. After the initial opening, the average in-use opening pressure was 16.9 kPa before area modification, and 13.1 kPa after the modification. The valve has been tested up to 10 000 open/close cycles under dry N 2 gas flow, and an additional 3000 open/close cycles under humid N 2 gas flow. The average forward flow conductance of the valves before modification was 1.1 sccm kPa −1 , and the conductance after modification was 1.41 sccm kPa −1 . The measured leakage is between 0.0003 and 0.004 sccm up to 35 kPa reverse pressure

  15. Flow effects due to valve and piston motion in an internal combustion engine exhaust port

    International Nuclear Information System (INIS)

    Semlitsch, Bernhard; Wang, Yue; Mihăescu, Mihai

    2015-01-01

    Highlights: • Flow regime identification depending on the valve lift during the exhaust stroke. • Analysis of the valve motion effect onto the flow development in the exhaust port. • Physical interpretation of commonly used discharge and flow coefficient formulations. • Illustration of flow effects in junction regions with pulsatile flow. - Abstract: Performance optimization regarding e.g. exhaust valve strategies in an internal combustion engine is often performed based on one-dimensional simulation investigation. Commonly, a discharge coefficient is used to describe the flow behavior in complex geometries, such as the exhaust port. This discharge coefficient for an exhaust port is obtained by laboratory experiments at fixed valve lifts, room temperatures, and low total pressure drops. The present study investigates the consequences of the valve and piston motion onto the energy losses and the discharge coefficient. Therefore, Large Eddy Simulations are performed in a realistic internal combustion geometry using three different modeling strategies, i.e. fixed valve lift and fixed piston, moving piston and fixed valve lift, and moving piston and moving valve, to estimate the energy losses. The differences in the flow field development with the different modeling approaches is delineated and the dynamic effects onto the primary quantities, e.g. discharge coefficient, are quantified. Considering the motion of piston and valves leads to negative total pressure losses during the exhaust cycle, which cannot be observed at fixed valve lifts. Additionally, the induced flow structures develop differently when valve motion is taken into consideration, which leads to a significant disparity of mass flow rates evolving through the two individual valve ports. However, accounting for piston motion and limited valve motion, leads to a minor discharge coefficient alteration of about one to two percent

  16. Percutaneous aortic valve implantation of the Medtronic CoreValve self-expanding valve prosthesis via left subclavian artery access: the first case report in Greece.

    Science.gov (United States)

    Karavolias, George K; Georgiadou, Panagiota; Houri, Mazen; Sbarouni, Eftihia; Thomopoulou, Sofia; Tsiapras, Dimitrios; Smirli, Anna; Balanika, Marina; Voudris, Vassilis

    2010-01-01

    This case report describes a percutaneous aortic valve implantation with the Medtronic CoreValve selfexpanding valve prosthesis in a patient with severe aortic stenosis. The approach was made via the left subclavian artery because of the lack of femoral vessel access. The patient was a 78-year-old female with breathlessness on minimal effort, a recent hospitalisation due to pulmonary oedema, and frequent episodes of pre-syncope; surgical valve replacement had been ruled out. The prosthetic valve was successfully implanted with mild paravalvular aortic regurgitation. At 30 days, the patient's clinical condition had significantly improved, with excellent functioning of the aortic valve prosthesis.

  17. Study on operation of a research reactor during one PCS pump failure accident

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Kyoung Woo; Yoon, Hyu Ngi; Kim, Seong Hoon; Chi, Dae Young; Yoon, Juh Yeon [KAERI, Daejeon (Korea, Republic of)

    2012-10-15

    The Primary cooling system (PCS) of a research reactor is designed to provide adequate cooling to the reactor core with a reasonable margin during all operation modes. The PCS consists of pumps, heat exchangers, and all necessary interconnecting pipes, valves, and instruments. The number of pumps is determined from a safety and economic point of view. As the number of pump trains increase, the cost increases according to the increase in safety class equipment. However, it is impossible to install one pump for a PCS because a zero flow can instantaneously occur during a pump failure such as a pump seizure. Thus, a PCS frequently consists of two parallel 50% capacity pumps and heat exchangers. In addition, check valves are generally installed to prevent a reversal flow when multiple pumps are designed to operate. However, if a swing type check valve is used, it should be estimated whether the slam due to instantaneous closing of the valve affects the system vibration. To reduce the vibration by a slam phenomenon, additional equipment such as a damper will be installed in the valve. The purpose of the check valve in PCS is to prevent the flow path when a reverse flow occurs. The installation of additional equipment will make it difficult to perform this function. In this study, it is estimated whether the PCS can operate without check valves. First, a flow analysis using Flowmaster was compared and verified by the calculation employing a empirical correlation. Second, the simulation for a one pump failure accident was performed and analyzed.

  18. Study on operation of a research reactor during one PCS pump failure accident

    International Nuclear Information System (INIS)

    Seo, Kyoung Woo; Yoon, Hyu Ngi; Kim, Seong Hoon; Chi, Dae Young; Yoon, Juh Yeon

    2012-01-01

    The Primary cooling system (PCS) of a research reactor is designed to provide adequate cooling to the reactor core with a reasonable margin during all operation modes. The PCS consists of pumps, heat exchangers, and all necessary interconnecting pipes, valves, and instruments. The number of pumps is determined from a safety and economic point of view. As the number of pump trains increase, the cost increases according to the increase in safety class equipment. However, it is impossible to install one pump for a PCS because a zero flow can instantaneously occur during a pump failure such as a pump seizure. Thus, a PCS frequently consists of two parallel 50% capacity pumps and heat exchangers. In addition, check valves are generally installed to prevent a reversal flow when multiple pumps are designed to operate. However, if a swing type check valve is used, it should be estimated whether the slam due to instantaneous closing of the valve affects the system vibration. To reduce the vibration by a slam phenomenon, additional equipment such as a damper will be installed in the valve. The purpose of the check valve in PCS is to prevent the flow path when a reverse flow occurs. The installation of additional equipment will make it difficult to perform this function. In this study, it is estimated whether the PCS can operate without check valves. First, a flow analysis using Flowmaster was compared and verified by the calculation employing a empirical correlation. Second, the simulation for a one pump failure accident was performed and analyzed

  19. Flow oscillations on the steam control valve in the middle opening condition. Clarification of the effects of valve body and valve seat by steam experiments

    International Nuclear Information System (INIS)

    Morita, Ryo; Inada, Fumio

    2007-01-01

    A steam control valve might cause vibrations of piping when the valve opening is in a middle condition. For rationalization of maintenance and management of the plant, the valve should be improved, but it is difficult to understand flow characteristics in detail by experiment because flow around the valve is complex 3D structure and becomes supersonic (M>1). Therefore, it is necessary to clarify the cause of the vibrations and to develop the countermeasures by CFD (Computational Fluid Dynamics) technology. In previous researches, we clarified a mechanism of the pressure fluctuations in the middle opening condition and suggested the new valve shape (named 'Extended Valve') that can suppress the pressure fluctuations by air experiments and CFD calculations. Then, we also conducted steam experiments and CFD calculations to understand the differences between air and the steam, and found that the pressure fluctuations in the middle opening condition also occurred in the steam tests and the differences between the air and steam were not remarkable. In this report, to clarify the effects of valve and valve seat shape in steam flow condition, we conduct the steam experiments with various valve and seat shape. As a result, we find the change of the valve seat can decrease the amplitude of pressure fluctuations, but can not quite suppress the pressure fluctuations in the middle opening condition. Then, we apply the 'Extended Valve' to clarify the valve shape effect, and find that the extended valve suppresses the pressure fluctuations in the middle opening condition completely and decreases the pressure amplitude drastically. (author)

  20. Nitric oxide synthase-3 promotes embryonic development of atrioventricular valves.

    Directory of Open Access Journals (Sweden)

    Yin Liu

    Full Text Available Nitric oxide synthase-3 (NOS3 has recently been shown to promote endothelial-to-mesenchymal transition (EndMT in the developing atrioventricular (AV canal. The present study was aimed to investigate the role of NOS3 in embryonic development of AV valves. We hypothesized that NOS3 promotes embryonic development of AV valves via EndMT. To test this hypothesis, morphological and functional analysis of AV valves were performed in wild-type (WT and NOS3(-/- mice at postnatal day 0. Our data show that the overall size and length of mitral and tricuspid valves were decreased in NOS3(-/- compared with WT mice. Echocardiographic assessment showed significant regurgitation of mitral and tricuspid valves during systole in NOS3(-/- mice. These phenotypes were all rescued by cardiac specific NOS3 overexpression. To assess EndMT, immunostaining of Snail1 was performed in the embryonic heart. Both total mesenchymal and Snail1(+ cells in the AV cushion were decreased in NOS3(-/- compared with WT mice at E10.5 and E12.5, which was completely restored by cardiac specific NOS3 overexpression. In cultured embryonic hearts, NOS3 promoted transforming growth factor (TGFβ, bone morphogenetic protein (BMP2 and Snail1expression through cGMP. Furthermore, mesenchymal cell formation and migration from cultured AV cushion explants were decreased in the NOS3(-/- compared with WT mice. We conclude that NOS3 promotes AV valve formation during embryonic heart development and deficiency in NOS3 results in AV valve insufficiency.

  1. Poor performances of EuroSCORE and CARE score for prediction of perioperative mortality in octogenarians undergoing aortic valve replacement for aortic stenosis.

    Science.gov (United States)

    Chhor, Vibol; Merceron, Sybille; Ricome, Sylvie; Baron, Gabriel; Daoud, Omar; Dilly, Marie-Pierre; Aubier, Benjamin; Provenchere, Sophie; Philip, Ivan

    2010-08-01

    Although results of cardiac surgery are improving, octogenarians have a higher procedure-related mortality and more complications with increased length of stay in ICU. Consequently, careful evaluation of perioperative risk seems necessary. The aims of our study were to assess and compare the performances of EuroSCORE and CARE score in the prediction of perioperative mortality among octogenarians undergoing aortic valve replacement for aortic stenosis and to compare these predictive performances with those obtained in younger patients. This retrospective study included all consecutive patients undergoing cardiac surgery in our institution between November 2005 and December 2007. For each patient, risk assessment for mortality was performed using logistic EuroSCORE, additive EuroSCORE and CARE score. The main outcome measure was early postoperative mortality. Predictive performances of these scores were assessed by calibration and discrimination using goodness-of-fit test and area under the receiver operating characteristic curve, respectively. During this 2-year period, we studied 2117 patients, among whom 134/211 octogenarians and 335/1906 nonoctogenarians underwent an aortic valve replacement for aortic stenosis. When considering patients with aortic stenosis, discrimination was poor in octogenarians and the difference from nonoctogenarians was significant for each score (0.58, 0.59 and 0.56 vs. 0.82, 0.81 and 0.77 for additive EuroSCORE, logistic EuroSCORE and CARE score in octogenarians and nonoctogenarians, respectively, P performances of these scores are poor in octogenarians undergoing cardiac surgery, especially aortic valve replacement. Risk assessment and therapeutic decisions in octogenarians should not be made with these scoring systems alone.

  2. Myocardial Protection and Financial Considerations of Custodiol Cardioplegia in Minimally Invasive and Open Valve Surgery.

    Science.gov (United States)

    Hummel, Brian W; Buss, Randall W; DiGiorgi, Paul L; Laviano, Brittany N; Yaeger, Nalani A; Lucas, M Lee; Comas, George M

    Single-dose antegrade crystalloid cardioplegia with Custodiol-HTK (histidine-tryptophan-ketoglutarate) has been used for many years. Its safety and efficacy were established in experimental and clinical studies. It is beneficial in complex valve surgery because it provides a long period of myocardial protection with a single dose. Thus, valve procedures (minimally invasive or open) can be performed with limited interruption. The aim of this study is to compare the use of Custodiol-HTK cardioplegia with traditional blood cardioplegia in patients undergoing minimally invasive and open valve surgery. A single-institution, retrospective case-control review was performed on patients who underwent valve surgery in Lee Memorial Health System at either HealthPark Medical Center or Gulf Coast Medical Center from July 1, 2011, through March 7, 2015. A total of 181 valve cases (aortic or mitral) performed using Custodiol-HTK cardioplegia were compared with 181 cases performed with traditional blood cardioplegia. Each group had an equal distribution of minimally invasive and open valve cases. Right chest thoracotomy or partial sternotomy was performed on minimally invasive valve cases. Demographics, perioperative data, clinical outcomes, and financial data were collected and analyzed. Patient outcomes were superior in the Custodiol-HTK cardioplegia group for blood transfusion, stroke, and hospital readmission within 30 days (P < 0.05). No statistical differences were observed in the other outcomes categories. Hospital charges were reduced on average by $3013 per patient when using Custodiol-HTK cardioplegia. Use of Custodiol-HTK cardioplegia is safe and cost-effective when compared with traditional repetitive blood cardioplegia in patients undergoing minimally invasive and open valve surgery.

  3. Enhancement of pressurizer safety valve operability by seating design improvement

    International Nuclear Information System (INIS)

    Moisidis, N.T.; Ratiu, M.D.

    1995-01-01

    Operating conditions specific to pressurizer safety valves (PSVs) have led to numerous problems and have caused industry and NRC concerns regarding the adequacy of spring-loaded self-actuated safety valves for reactor coolant system (RCS) overpressure protection. Specific concerns are: setpoint drift, spurious actuations, and pressure protection. Specific concerns are: setpoint drift, spurious actuations, and leakage. Based on testing and valve construction analysis of a Crosby model 6M6 PSV (Moisidis and Ratiu, 1992), it was established that the primary contributor to the valve problems is a susceptibility to weak seating. To eliminate spring instability, a new spring washer was designed, which guides the spring and precludes its rotation from the reference installed position. Results of tests performed on a prototype PSV equipped with the modified upper spring washer has shown significant improvements in valve operability and a consistent setpoint reproducibility to less than ±1% of the PSV setpoint (testing of baseline, unmodified valve, resulted in a setpoint drift of ± 2%). Enhanced valve operability will result in a significant decrease in operating and maintenance costs associated with valve maintenance and testing. In addition, the enhanced setpoint reproducibility will allow the development of a nitrogen to steam correlation for future in-house PSV testing which will result in further reductions in costs associated with valve testing

  4. Effects of the blockage ratio of a valve disk on loss coefficient in a butterfly valve

    International Nuclear Information System (INIS)

    Rho, Hyung Joon; Lee, Jee Keun; Choi, Hee Joo

    2008-01-01

    The loss coefficient of the butterfly valve which allows partial opening of the valve at closed position and is applicable to the small-sized pipe system with the diameter of 1 inch was measured for the variation of the valve disk blockage ratio. Two different types of the valve disk configuration to adjust the blockage ratio were considered. One was the solid type valve disk of which the diameter was changed into the smaller size rather than the pipe diameter, and the other was the perforate type valve disk on which some holes were perforated. The results from two types of valve disk were compared to identify their characteristics in the loss coefficient distributions. The loss coefficient and the controllable angle of the valve disk were decreased exponentially with the decrease of the blockage ratio. In addition, the perforate valve disk had the effect on the higher loss coefficient rather than the solid type valve disk

  5. Door valve for fuel handling path

    International Nuclear Information System (INIS)

    Makishima, Katsuhiko.

    1969-01-01

    A door valve is provided which seals cover gas from a liquid metal cooled reactor without leakage therefrom. A threaded shaft is screwed into a heavy box press which is packed with lead. The shaft is adapted to be rotated by an electric motor or a manually operated wheel which is disposed outside of the door valve. A valve plate is suspended from the box press by four guide wheels mounted thereon. The guide wheels are fitted into inclined guide grooves formed at the valve plate and into grooved formed in the inner wall of a valve casing. A locking ball is provided at each side of the valve plate. In operation the shaft rotates and travels to permit the box press and the valve plate to move into the door valve casing, thus releasing the locking balls. The valve plate does not contact the bottom of the casing. When the box press reaches the home position, the valve plate is carried on the valve opening, and the box press presses the valve plate to increase the tightness. The valve plate does not suffer wear as it does not slide over other parts. (Yamaguchi, T.)

  6. Unicuspid aortic valve disease: a magnetic resonance imaging study

    International Nuclear Information System (INIS)

    Debl, K.; Buchner, S.; Heinicke, N.; Riegger, G.; Luchner, A.; Djavidani, B.; Poschenrieder, F.; Feuerbach, S.; Schmid, C.; Kobuch, R.

    2008-01-01

    Purpose: congenitally malformed aortic valves are a common finding in adults with aortic valve disease. Most of these patients have bicuspid aortic valve disease. Unicuspid aortic valve disease (UAV) is rare. The aim of our study was to describe valve morphology and the dimensions of the proximal aorta in a cohort of 12 patients with UAV in comparison to tricuspid aortic valve disease (TAV) using magnetic resonance imaging (MRI). Materials and methods/results: MRI studies were performed on a 1.5 T scanner in a total of 288 consecutive patients with aortic valve disease. 12 aortic valves were retrospectively classified as UAV. Annulus areas and dimensions of the thoracic aorta were retrospectively compared to a cohort of 103 patients with TAV. In UAV, valve morphology was unicuspid unicommissural with a posterior commissure in all patients. Mean annulus areas and mean diameters of the ascending aorta were significantly greater in UAV compared to TAV (12.6 ± 4.7 cm 2 vs. 8.7 ± 2.3 cm 2 , p < 0.01 and 4.6 ± 0.7 cm vs. 3.6 ± 0.5 cm, p < 0.0001, respectively), while no differences were observed in the mean diameters of the aortic arch (2.3 ± 0.6 cm vs. 2.3 ± 0.4 cm, p = 0.69). The diameters of the descending aorta were slightly smaller in UAV compared to TAV (2.2 ± 0.5 cm vs. 2.6 ± 0.3 cm, p < 0.05). (orig.)

  7. Keep pushing! Limiting interruptions to CPR; bag-valve mask versus ...

    African Journals Online (AJOL)

    This has led to first responders and paramedics performing single rescuer CPR using a bag-valve-mask (BVM) device as opposed to the historical practice of intubating and ventilating via an endotracheal tube. Bag-valve-mask ventilations, especially during single rescuer CPR, are however associated with complications ...

  8. Lymphangiogenesis is increased in heart valve endocarditis.

    Science.gov (United States)

    Niinimäki, Eetu; Mennander, Ari A; Paavonen, Timo; Kholová, Ivana

    2016-09-15

    Inflammation-associated lymphangiogenesis (IAL) has been identified as part of several acute and chronic inflammation. Sparse data exist on lymphatics during endocarditis. Fifty-two patients with surgically resected valves were included. Endocarditis was present in 18 aortic and 10 mitral valves. Controls consisted of 15 degenerative aortic and 9 degenerative mitral valves. There were 22 males with endocarditis and 17 males in controls. The mean age was 58 (SD 15) years with endocarditis vs. 62 (SD 13) years for controls. Lymphatics were detected by podoplanin antibody immunohistochemistry and morphometrical analysis was performed. The lymphatic density in endocarditis was 833 (SD 529) vessels/mm(2) (range 0-1707) as compared with 39 (SD 60) vessels/mm(2) (range 0-250) in controls (p=0.000). In endocarditis, the mean lymphatic size was 153 (SD 372) μm(2) ranging from 1 to 2034μm(2), whereas it was 30 (SD 29) μm(2), with maximum 90μm(2) and minimum 2μm(2) in controls (p=0.000). IAL is increased in valves with endocarditis as compared with controls. Lymphatics in heart valves may provide a novel means for treatment strategies against endocarditis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Characterization of a bioprosthetic bicuspid venous valve hemodynamics: implications for mechanism of valve dynamics.

    Science.gov (United States)

    Tien, W-H; Chen, H Y; Berwick, Z C; Krieger, J; Chambers, S; Dabiri, D; Kassab, G S

    2014-10-01

    Chronic venous insufficiency (CVI) of the lower extremities is a common clinical problem. Although bioprosthetic valves have been proposed to treat severe reflux, clinical success has been limited due to thrombosis and neointima overgrowth of the leaflets that is, in part, related to the hemodynamics of the valve. A bioprosthetic valve that mimics native valve hemodynamics is essential. A computational model of the prosthetic valve based on realistic geometry and mechanical properties was developed to simulate the interaction of valve structure (fluid-structure interaction, FSI) with the surrounding flow. The simulation results were validated by experiments of a bioprosthetic bicuspid venous valve using particle image velocimetry (PIV) with high spatial and temporal resolution in a pulse duplicator (PD). Flow velocity fields surrounding the valve leaflets were calculated from PIV measurements and comparisons to the FSI simulation results were made. Both the spatial and temporal results of the simulations and experiments were in agreement. The FSI prediction of the transition point from equilibrium phase to valve-closing phase had a 7% delay compared to the PD measurements, while the PIV measurements matched the PD exactly. FSI predictions of reversed flow were within 10% compared to PD measurements. Stagnation or stasis regions were observed in both simulations and experiments. The pressure differential across the valve and associated forces on the leaflets from simulations showed the valve mechanism to be pressure driven. The flow velocity simulations were highly consistent with the experimental results. The FSI simulation and force analysis showed that the valve closure mechanism is pressure driven under the test conditions. FSI simulation and PIV measurements demonstrated that the flow behind the leaflet was mostly stagnant and a potential source for thrombosis. The validated FSI simulations should enable future valve design optimizations that are needed for

  10. Impact of valve failures on the safety and reliability of light water nuclear power plants

    International Nuclear Information System (INIS)

    Riddington, J.W.; Reyer, R.J.

    1980-01-01

    A study of the causes of, and solutions for, recurrent valve failures has been performed. The frequency and root causes of valve problems were identified from licensee event reports and meetings with utility, NSSS, and valve manufacturer personnel. Three generic problems (stem leakage, seat leakage, and inadequate specification) and four valve specific problems were identified. The four valve specific problems and their principal causes are: (1) BWR pilot operated safety relief valves (pilot valve leakage); (2) spring loaded safety relief valves (water solid and two-phase flow behavior); (3) PWR feedwater regulating valves (trim degradation and packing failures); and (4) air operated solenoid valves (jamming due to foreign matter in service air). The first two valve specific problems are the subject of current industry programs. Programs intended to address stem leakage, seat leakage, timely exchange of valve failure information, testing of valves, and adequate specification, selection, and maintenance of valves will be outlined

  11. Nasal valve evaluation in the Mexican-Hispanic (mestizo) nose.

    Science.gov (United States)

    Jasso-Ramírez, Elizabeth; Sánchez Y Béjar, Fernando; Arcaute Aizpuru, Fernando; Maulen Radován, Irene E; de la Garza Hesles, Héctor

    2018-04-01

    Our aim in this study was to determine the angle of the internal nasal valve in Mexican patients with the "mestizo nose" feature and without nasal obstructive symptoms. The work was prospective, comparative, and observational in nature and included patients >14 years of age who were seen in the Otolaryngology Department at the Los Angeles Lomas Hospital between April and May 2016. The angle of the internal nasal valve was measured in 30 patients without obstructive symptoms. Endoscopic examination was performed with a 0° endoscope framed with tape at a 13-mm distance from the endoscope's tip, and digital photographs of the internal nasal valve were taken. The measurement of the angle of the internal nasal valve was made in sexagesimal degrees using Golden Ratio v3.1 (2012) software. Statistical analysis was performed using Excel v15.13.3. The angles of the internal nasal valve of the patients were (mean ± standard deviation) 24.07 ± 4.8° for the right nasal cavity and 25.07 ± 5.0° for the left nasal cavity, wider than the angle reported in the normal Caucasian nose established in the literature. According to our results, the Mexican-Hispanic mestizo nose has a wider angle in the internal nasal valve than that considered normal in the literature (10°-15°). We believe it is necessary to undertake a second study and add an airflow resistance measurement with a rhinomanometry procedure so we can compare the results with those in the Caucasian population. © 2018 ARS-AAOA, LLC.

  12. Low intake valve lift in a port fuel-injected engine

    Energy Technology Data Exchange (ETDEWEB)

    Begg, S.M.; Hindle, M.P.; Cowell, T.; Heikal, M.R. [The Sir Harry Ricardo Laboratories, Centre for Automotive Engineering, Cockcroft Building, University of Brighton, Lewes Road, Brighton, East Sussex, BN2 4GJ (United Kingdom)

    2009-12-15

    A phenomenological study of the airflow and fuel spray interaction in a variable valve gasoline engine is presented. Experiments were performed in a steady-state flow rig fitted with a modified production cylinder head. The intake valve lift was varied manually. The mass flow rates of air and fuel through the test rig were adjusted to match typical engine operating conditions. Particle Image Velocimetry (PIV) and Laser Doppler Anemometry (LDA) measurements of the airflow showed the breakdown of a single, forward tumbling vortex-like structure into a pair of high-speed, turbulent jets at low valve lifts. Two transitional phases in the flow at the valve gap were identified for valve lifts less than 1.5 mm and greater than 3 mm. At the lower limit, a jet flapping instability was recorded. A port fuel injector (PFI) spray was characterised in a quiescent, chamber and within the test rig. High Speed Photography (HSP) and Phase Doppler Anemometry (PDA) were used to measure the effects of varying valve lift upon the fuel droplet characteristics. The in-cylinder measurements showed a reduction in mean droplet diameter of up to 50%, close to the valve gap, for peak valve lifts of less than 3 mm. (author)

  13. Engine Cycle Analysis of Air Breathing Microwave Rocket with Reed Valves

    International Nuclear Information System (INIS)

    Fukunari, Masafumi; Komatsu, Reiji; Yamaguchi, Toshikazu; Komurasaki, Kimiya; Arakawa, Yoshihiro; Katsurayama, Hiroshi

    2011-01-01

    The Microwave Rocket is a candidate for a low cost launcher system. Pulsed plasma generated by a high power millimeter wave beam drives a blast wave, and a vehicle acquires impulsive thrust by exhausting the blast wave. The thrust generation process of the Microwave Rocket is similar to a pulse detonation engine. In order to enhance the performance of its air refreshment, the air-breathing mechanism using reed valves is under development. Ambient air is taken to the thruster through reed valves. Reed valves are closed while the inside pressure is high enough. After the time when the shock wave exhausts at the open end, an expansion wave is driven and propagates to the thrust-wall. The reed valve is opened by the negative gauge pressure induced by the expansion wave and its reflection wave. In these processes, the pressure oscillation is important parameter. In this paper, the pressure oscillation in the thruster was calculated by CFD combined with the flux through from reed valves, which is estimated analytically. As a result, the air-breathing performance is evaluated using Partial Filling Rate (PFR), the ratio of thruster length to diameter L/D, and ratio of opening area of reed valves to superficial area α. An engine cycle and predicted thrust was explained.

  14. A comparison of conventional surgery, transcatheter aortic valve replacement, and sutureless valves in "real-world" patients with aortic stenosis and intermediate- to high-risk profile.

    Science.gov (United States)

    Muneretto, Claudio; Alfieri, Ottavio; Cesana, Bruno Mario; Bisleri, Gianluigi; De Bonis, Michele; Di Bartolomeo, Roberto; Savini, Carlo; Folesani, Gianluca; Di Bacco, Lorenzo; Rambaldini, Manfredo; Maureira, Juan Pablo; Laborde, Francois; Tespili, Maurizio; Repossini, Alberto; Folliguet, Thierry

    2015-12-01

    We sought to investigate the clinical outcomes of patients with isolated severe aortic stenosis and an intermediate- to high-risk profile treated by means of conventional surgery (surgical aortic valve replacement), sutureless valve implantation, or transcatheter aortic valve replacement in a multicenter evaluation. Among 991 consecutive patients with isolated severe aortic stenosis and an intermediate- to high-risk profile (Society of Thoracic Surgeons score >4 and logistic European System for Cardiac Operative Risk Evaluation I >10), a propensity score analysis was performed on the basis of the therapeutic strategy: surgical aortic valve replacement (n = 204), sutureless valve implantation (n = 204), and transcatheter aortic valve replacement (n = 204). Primary end points were 30-day mortality and overall survival at 24-month follow-up; the secondary end point was survival free from a composite end point of major adverse cardiac events (defined as cardiac-related mortality, myocardial infarction, cerebrovascular accidents, and major hemorrhagic events) and periprosthetic regurgitation greater than 2. Thirty-day mortality was significantly higher in the transcatheter aortic valve replacement group (surgical aortic valve replacement = 3.4% vs sutureless = 5.8% vs transcatheter aortic valve replacement = 9.8%; P = .005). The incidence of postprocedural was 3.9% in asurgical aortic valve replacement vs 9.8% in sutureless vs 14.7% in transcatheter aortic valve replacement (Prisk factor for overall mortality hazard ratio (hazard ratio, 2.5; confidence interval, 1.1-4.2; P = .018). The use of transcatheter aortic valve replacement in patients with an intermediate- to high-risk profile was associated with a significantly higher incidence of perioperative complications and decreased survival at short- and mid-term when compared with conventional surgery and sutureless valve implantation. Copyright © 2015 The American Association for Thoracic Surgery. Published by

  15. Cryogenic Cam Butterfly Valve

    Science.gov (United States)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  16. Theoretical seismic analysis of butterfly valve for nuclear power plant

    International Nuclear Information System (INIS)

    Han, Sang Uk; Ahn, Jun Tae; Han, Seung Ho; Lee, Kyung Chul

    2012-01-01

    Valves are one of the most important components of a pipeline system in a nuclear power plant, and it is important to ensure their structural safety under seismic loads. A crucial aspect of structural safety verification is the seismic qualification, and therefore, an optimal shape design and experimental seismic qualification is necessary in case the configuration of the valve parts needs to be modified and their performance needs to be improved. Recently, intensive numerical analyses have been preformed before the experimental verification in order to determine the appropriate design variables that satisfy the performance requirements under seismic loads. In this study, static and dynamic numerical structural analyses of a 200A butterfly valve for a nuclear power plant were performed according to the KEPIC MFA. The result of static analysis considering an equivalent static load under SSE condition gave an applied stress of 135MPa. In addition, the result of dynamic analysis gave an applied stress of 183MPa, where the CQC method using response spectrums was taken into account. These values are under the allowable strength of the materials used for manufacturing the butterfly valve, and therefore, its structural safety satisfies the requirements of KEPIC MFA

  17. Theoretical seismic analysis of butterfly valve for nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Han, Sang Uk; Ahn, Jun Tae; Han, Seung Ho [Donga Univ., Busan (Korea, Republic of); Lee, Kyung Chul [Dukwon Valve Co., Ltd., Busan (Korea, Republic of)

    2012-09-15

    Valves are one of the most important components of a pipeline system in a nuclear power plant, and it is important to ensure their structural safety under seismic loads. A crucial aspect of structural safety verification is the seismic qualification, and therefore, an optimal shape design and experimental seismic qualification is necessary in case the configuration of the valve parts needs to be modified and their performance needs to be improved. Recently, intensive numerical analyses have been preformed before the experimental verification in order to determine the appropriate design variables that satisfy the performance requirements under seismic loads. In this study, static and dynamic numerical structural analyses of a 200A butterfly valve for a nuclear power plant were performed according to the KEPIC MFA. The result of static analysis considering an equivalent static load under SSE condition gave an applied stress of 135MPa. In addition, the result of dynamic analysis gave an applied stress of 183MPa, where the CQC method using response spectrums was taken into account. These values are under the allowable strength of the materials used for manufacturing the butterfly valve, and therefore, its structural safety satisfies the requirements of KEPIC MFA.

  18. Small valve area index: its influence on early mortality after mitral valve replacement

    NARCIS (Netherlands)

    Yazdanbakhsh, A. P.; van den Brink, R. B.; Dekker, Egbert; de Mol, B. A.

    2000-01-01

    OBJECTIVE: To test the hypothesis that mitral valve prosthesis-patient mismatch increases postoperative mortality. METHODS AND RESULTS: The effect of mitral valve prosthesis-patient mismatch on survival in a cohort of consecutive patients after mitral valve replacement with a mechanical prosthesis

  19. 14 CFR 121.411 - Qualifications: Check airmen (airplane) and check airmen (simulator).

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Qualifications: Check airmen (airplane) and... § 121.411 Qualifications: Check airmen (airplane) and check airmen (simulator). (a) For the purposes of this section and § 121.413: (1) A check airman (airplane) is a person who is qualified, and permitted...

  20. Flow mapping for assessment of native and repaired valves

    International Nuclear Information System (INIS)

    Felner, J.; Pollack, S.; McMillan, S.; Yoganathan, A.; Knopf, W.; Craver, J.

    1986-01-01

    Color Doppler flow mapping (CDFM) was performed in 47 normal women ages 18-41 mean (m) 28 to determine the normal flow phenomena across each of the 4 heart valves. The group included: 15 elite marathon runners average run (ave.) 70 miles/week, heart rate (HR) 35-54 (m 45); 14 joggers ave. 40 mi/wkm HR 40-69 (m 53); and 17 controls 0 mi/wk, HR 49-93 (m 77). 2-D echo and CDFM defined the motion of each valve, including the presence of mitral valve prolapse (MVP), the ventricular inflow and outflow patterns and the presence of regurgitation

  1. Ten-year results of the Freedom Solo stentless heart valve: excellent haemodynamics but progressive valve dysfunction in the long term.

    Science.gov (United States)

    Sponga, Sandro; Barbera, Mila Della; Pavoni, Daisy; Lechiancole, Andrea; Mazzaro, Enzo; Valente, Marialuisa; Nucifora, Gaetano; Thiene, Gaetano; Livi, Ugolino

    2017-05-01

    Freedom Solo (FS) is a pericardial stentless heart valve showing excellent haemodynamic performance at mid-term. The aim of this study was to evaluate the long-term performance of such bioprostheses. Between December 2004 and November 2009, 109 patients (31 men; mean age 76 ± 6 years) underwent aortic valve replacement with FS. Preoperatively, the mean NYHA class was 2.5 ± 0.7, the mean EuroSCORE II, 2.8 ± 2.5. Mean prosthesis size was 22.7 ± 1.9 mm; concomitant procedures were performed in 65 patients. Structural valve deterioration (SVD) was diagnosed according to the Valve Academic Research Consortium-2 definition. Two patients (1.8%) died within 30 days. Follow-up (72 ± 36 months) was 100% completed. The 1-, 5- and 10-year actuarial survival rates were 89, 73 and 42%, respectively, with 8 valve-related deaths; the actuarial freedom from SVD was 99, 93 and 76%. During 61 ± 39 months of follow-up, echocardiographic findings worsened progressively: At discharge, 3-5 and 7-9 years, the mean gradient was 8 ± 4, 12 ± 11 and 19 ± 19 mmHg ( P  < 0.01); the indexed effective orifice area was 1.0 ± 0.2, 0.9 ± 0.2 and 0.8 ± 0.3 cm 2 /m 2 ( P  < 0.01). Of the 13 patients who developed SVD, it was due to aortic stenosis in 11. SVD was a predictor of cardiovascular mortality at univariate analysis (HR 2.87, 1.12-7.29); 2 explanted prostheses showed massive calcium deposits with mean calcium and phosphorus contents of 234 ± 16 and 116 ± 7 mg/g dry weight, respectively. The FS bioprosthesis shows excellent mid-term clinical and haemodynamic results and offers an alternative to other valves, particularly in the case of a small aortic annulus. Worsening of FS performance was observed at late follow-up because of progressive SVD with stenosis, questioning whether it should be used in patients with a long life expectancy. © The Author 2017. Published by Oxford University Press on behalf of the

  2. Björk-Shiley convexoconcave valves: susceptibility artifacts at brain MR imaging and mechanical valve fractures.

    Science.gov (United States)

    van Gorp, Maarten J; van der Graaf, Yolanda; de Mol, Bas A J M; Bakker, Chris J G; Witkamp, Theo D; Ramos, Lino M P; Mali, Willem P T M

    2004-03-01

    To assess the relationship between heart valve history and susceptibility artifacts at magnetic resonance (MR) imaging of the brain in patients with Björk-Shiley convexoconcave (BSCC) valves. MR images of the brain were obtained in 58 patients with prosthetic heart valves: 20 patients had BSCC valve replacements, and 38 had other types of heart valves. Two experienced neuroradiologists determined the presence or absence of susceptibility artifacts in a consensus reading. Artifacts were defined as characteristic black spots that were visible on T2*-weighted gradient-echo MR images. The statuses of the 20 explanted BSCC valves-specifically, whether they were intact or had an outlet strut fracture (OSF) or a single-leg fracture (SLF)-had been determined earlier. Number of artifacts seen at brain MR imaging was correlated with explanted valve status, and differences were analyzed with nonparametric statistical tests. Significantly more patients with BSCC valves (17 [85%] of 20 patients) than patients with other types of prosthetic valves (18 [47%] of 38 patients) had susceptibility artifacts at MR imaging (P =.005). BSCC valve OSFs were associated with a significantly higher number of artifacts than were intact BSCC valves (P =.01). No significant relationship between SLF and number of artifacts was observed. Susceptibility artifacts at brain MR imaging are not restricted to patients with BSCC valves. These artifacts can be seen on images obtained in patients with various other types of fractured and intact prosthetic heart valves. Copyright RSNA, 2004

  3. Curved butterfly bileaflet prosthetic cardiac valve

    Science.gov (United States)

    McQueen, David M.; Peskin, Charles S.

    1991-06-25

    An annular valve body having a central passageway for the flow of blood therethrough with two curved leaflets each of which is pivotally supported on an accentric positioned axis in the central passageway for moving between a closed position and an open position. The leaflets are curved in a plane normal to the eccentric axis and positioned with the convex side of the leaflets facing each other when the leaflets are in the open position. Various parameters such as the curvature of the leaflets, the location of the eccentric axis, and the maximum opening angle of the leaflets are optimized according to the following performance criteria: maximize the minimum peak velocity through the valve, maximize the net stroke volume, and minimize the mean forward pressure difference, thereby reducing thrombosis and improving the hemodynamic performance.

  4. An air-pressure-free elastomeric valve for integrated nucleic acid analysis by capillary electrophoresis

    International Nuclear Information System (INIS)

    Jung, Wooseok; Barrett, Matthew; Brooks, Carla; Zenhausern, Frederic; Rivera, Andrew; Birdsell, Dawn N; Wagner, David M

    2015-01-01

    We present a new elastomeric valve for integrated nucleic acid analysis by capillary electrophoresis. The valve functions include metering to capture a designated volume of biological sample into a polymerase chain reaction (PCR) chamber, sealing to preserve the sample during PCR cycling, and transfer of the PCR-products and on-chip formamide post-processing for the analysis of DNA fragments by capillary gel electrophoresis. This new valve differs from prior art polydimethylsiloxane (PDMS) valves in that the valve is not actuated externally by air-pressure or vacuum so that it simplifies a DNA analysis system by eliminating the need for an air-pressure or vacuum source, and off-cartridge solenoid valves, control circuit boards and software. Instead, the new valve is actuated by a thermal cycling peltier assembly integrated within the hardware instrument that tightly comes in contact with a microfluidic cartridge for thermal activation during PCR, so that it spontaneously closes the valve without an additional actuator system. The valve has bumps in the designated locations so that it has a self-alignment that does not require precise alignment of a valve actuator. Moreover, the thickness of the new valve is around 600 μm with an additional bump height of 400 μm so that it is easy to handle and very feasible to fabricate by injection molding compared to other PDMS valves whose thicknesses are around 30–100 μm. The new valve provided over 95% of metering performance in filling the fixed volume of the PCR chamber, preserved over 97% of the sample volume during PCR, and showed very comparable capillary electrophoresis peak heights to the benchtop assay tube controls with very consistent transfer volume of the PCR-product and on-chip formamide. The new valve can perform a core function for integrated nucleic acid analysis by capillary electrophoresis. (paper)

  5. Typical performance of regular low-density parity-check codes over general symmetric channels

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Toshiyuki [Department of Electronics and Information Engineering, Tokyo Metropolitan University, 1-1 Minami-Osawa, Hachioji-shi, Tokyo 192-0397 (Japan); Saad, David [Neural Computing Research Group, Aston University, Aston Triangle, Birmingham B4 7ET (United Kingdom)

    2003-10-31

    Typical performance of low-density parity-check (LDPC) codes over a general binary-input output-symmetric memoryless channel is investigated using methods of statistical mechanics. Relationship between the free energy in statistical-mechanics approach and the mutual information used in the information-theory literature is established within a general framework; Gallager and MacKay-Neal codes are studied as specific examples of LDPC codes. It is shown that basic properties of these codes known for particular channels, including their potential to saturate Shannon's bound, hold for general symmetric channels. The binary-input additive-white-Gaussian-noise channel and the binary-input Laplace channel are considered as specific channel models.

  6. Typical performance of regular low-density parity-check codes over general symmetric channels

    International Nuclear Information System (INIS)

    Tanaka, Toshiyuki; Saad, David

    2003-01-01

    Typical performance of low-density parity-check (LDPC) codes over a general binary-input output-symmetric memoryless channel is investigated using methods of statistical mechanics. Relationship between the free energy in statistical-mechanics approach and the mutual information used in the information-theory literature is established within a general framework; Gallager and MacKay-Neal codes are studied as specific examples of LDPC codes. It is shown that basic properties of these codes known for particular channels, including their potential to saturate Shannon's bound, hold for general symmetric channels. The binary-input additive-white-Gaussian-noise channel and the binary-input Laplace channel are considered as specific channel models

  7. Organic evaporator steam valve failure

    International Nuclear Information System (INIS)

    Jacobs, R.A.

    1992-01-01

    Defense Waste Processing Facility (DWPF) Technical has requested an analysis of the capacity of the Organic Evaporator (OE) condenser (OEC) be performed to determine its capability in the case where the OE steam flow control valve fails open. Calculations of the OE boilup and the OEC heat transfer coefficient indicate the OEC will have more than enough capacity to remove the heat at maximum OE boilup. In fact, the Salt Cell Vent Condenser (SCVC) should also have sufficient capacity to handle the maximum OE boilup. Therefore, it would require simultaneous loss of OEC and/or SCVC condensing capacity for the steam valve failure to cause high benzene in the Process Vessel Vent System (PVVS)

  8. Low noise control valve

    International Nuclear Information System (INIS)

    Christie, R.S.

    1975-01-01

    Noise is one of the problems associated with the use of any type of control valve in systems involving the flow of fluids. The advent of OSHA standards has prompted control valve manufacturers to design valves with special trim to lower the sound pressure level to meet these standards. However, these levels are in some cases too high, particularly when a valve must be located in or near an area where people are working at tasks requiring a high degree of concentration. Such locations are found around and near research devices and in laboratory-office areas. This paper describes a type of fluid control device presently being used at PPL as a bypass control valve in deionized water systems and designed to reduce sound pressure levels considerably below OSHA standards. Details of the design and construction of this constant pressure drop variable flow control valve are contained in the text and are shown in photographs and drawings. Test data taken are included

  9. Efficiency of aortic valve commissurotomy for congenital aortic valve stenosis in pediatric population

    Directory of Open Access Journals (Sweden)

    А. А. Лукьянов

    2015-10-01

    Full Text Available Background. This study was designed to evaluate short-term and long-term outcomes after open aortic valve commissurotomy in the pediatric patients at our center over a period of 10 years. Methods. A retrospective study of 94 patients who underwent open surgical commissurotomy because of aortic valve stenosis between 2003 and 2013 is presented. Follow-up time was in the range of 1 to 7 years. Results. The open aortic valve commissurotomy combined with debridement of leaflet free edge 36.1 %, LVOT myectomy 11.7%, leaflet suture plastic 7.4%, modified Konno procedure 6.3%, Brom's aortoplasty 4.2% was performed for all patients. Average cardiopulmonary bypass time was 59.2 30.7 min. Median aortic cross-clamping time was 31.52 15.1 min. Hospital complications were observed in 38.2% of cases. ICU time was in the range of 1 to 31 (mean 3.2 5.1 day. Artificial lung ventilation time varied from 2 to 76 (mean 15.3 18.3 hours. Inotropic support was needed in 26.5% of cases. Mean hospital stay time was 17.1 7.3 days. At follow-up between 2 and 7 years, reoperations were required for 3 patients who underwent a Ross procedure. Conclusions. The results evidence that open surgical commissurotomy is an effective way of treatment for aortic valve stenosis, considering the accuracy of plasty and additional techniques of leaflet correction. The best children age group for this type of operation is from first to five years of life.

  10. Idiopathic mitral valve prolapse with tricuspid, aortic and pulmonary valve involvement: An autopsy case report

    Directory of Open Access Journals (Sweden)

    Heena M Desai

    2015-01-01

    Full Text Available Mitral valve prolapse (MVP is usually asymptomatic, but can be associated with complications such as infective endocarditis, mitral regurgitation, thromboembolism and sudden cardiac death. It has been very rarely reported to occur in association with other valvular involvement. A 55-year-old male patient was brought dead and at autopsy the mitral valve orifice was stenotic and the leaflets were enlarged, myxoid and bulging suggestive of MVP and chordae tendinae were thickened, stretched and elongated. Similar changes were seen in the tricuspid valve. The pulmonary and aortic valves also showed myxomatous degeneration of their cusps. Myxomatous degeneration is the most common cause of MVP and it can be associated with involvement of the other valves. Concomitant involvement of the aortic valve has been reported, however it is very rare and simultaneous involvement of the pulmonary valve has not been reported in the literature so far. We report a case of MVP associated with myxomatous degeneration of the tricuspid, pulmonary and aortic valves.

  11. Thrombocytopenia following implantation of the stentless biological sorin freedom SOLO valve.

    Science.gov (United States)

    Gersak, Borut; Gartner, Urska; Antonic, Miha

    2011-07-01

    Stentless biological valves have proven advantages in hemodynamic performance and left ventricular function compared to stented biological valves. Following a marked postoperative fall in the platelet count of patients after implantation of the Freedom SOLO valve, the study aim was to confirm clinical observations that this effect was more severe in patients receiving Freedom SOLO valves than in those receiving St. Jude Medical (SJM) mechanical aortic valves. Preoperative and postoperative platelet counts were compared in two groups of patients who underwent aortic valve replacement (AVR) without any concomitant procedures between January and December 2007. Patients received either a Freedom SOLO valve (n = 28) or a SJM mechanical valve (n = 41). Mean values of platelet counts were compared using three multiple linear regression models. Platelet counts were significantly lower in the Freedom SOLO group than in the SJM group from the first postoperative day (POD 1) up to POD 6 (p SOLO group the platelet count fell below 30x10(9)/l, while the lowest level in the SJM group was 75x10(9)/l. Based on multiple linear regression models, the type of valve implanted had a statistically significant influence on postoperative platelet counts on POD 1, POD 3, and POD 5 (p SOLO group.

  12. A study on the force balance of an unbalanced globe valve

    International Nuclear Information System (INIS)

    Yang, Sang Min; Cho, Taik Dong; Ko, Sung Ho; Lee, Ho Young

    2007-01-01

    A pneumatic control valve is a piping element that controls the volumetric flow rate and pressure of a fluid: it is necessary to analyze the characteristics of the forces with respect to the opening of the valve in order to evaluate its operating performance. The forces occurring during operation are: resisting force and actuator force, where the load resistance is mostly affected by the fluid pressure difference of the valve. In this study, a force balance equation derived from the equilibrium relationship between the resisting force and the actuator force of an unbalanced globe valve is proposed, and the force balance equations are used to model the dynamic equations of a pneumatic unbalanced globe valve installed in nuclear power plants. A CFD analysis is also carried out to evaluate the pressure distribution and forces acting on the top and bottom planes of the valve plug. The results of this analysis have been verified through experimentation. This study has shown that the fluid pressure difference between the inlet and outlet of the valve, measured from the force balance equation of an unbalanced valve, should actually be examined with the fluid-pressure difference between the top and bottom side of the valve plug

  13. Banking cryopreserved heart valves in Europe: assessment of a 5-year operation in an international tissue bank in Brussels.

    Science.gov (United States)

    Goffin, Y; Grandmougin, D; Van Hoeck, B

    1996-01-01

    The heart valve bank of the European Homograft Bank has been set up in 1988 to meet the growing demand of cardiac surgeons for various sized and quality controlled cryopreserved homografts. Heart valve donors less than 60 years of age were classified in 3 categories: multiorgan donors with non transplantable hearts, recipients of cardiac transplantation and non beating heart cadavers with a warm ischemic time of less than 6 hours. Past history and biology were checked for transmissible diseases. Preparation, progressive freezing and storage in liquid nitrogen vapors, and quality control were according to the standards of the Belgian Ministry of Health. From end January 1989 to end May 1994, 989 homograft valves were cryopreserved (514 pulmonary, 475 aortic and 3 mitral) whereas 962 valves were discarded. The first cause of rejection being a major macroscopic lesion (41.48%). 138 hearts accepted at inspection were contaminated and 43 cases remained so after antibiotics. 38 cases were positive for hepatitis B or C. Complication at distribution and thawing included 10 instances of bag rupture and 15 of transversal fracture through the wall of the conduit. 477 aortic, 474 pulmonary valves as well as one mitral were implanted between May 1989 and May 1994, either for left or right ventricular outflow tract reconstruction. In the left ventricular outflow tract series 111 aortic and 23 pulmonary homograft valves were used in cases of native endocarditis, prosthetic endocarditis or recurrent endocarditis after homograft implantation. 9.6% of the requests could no be satisfied. Regular follow up information was available from 382 implants-40.1% only. The assessment of 5 years operation of the heart valve bank indicates: 1) the efficiency of selecting, cryopreserving and allocating quality controlled homograft valves from a large pool of donor hearts provided by a network of hospitals; 2) the difficulty of obtaining regular follow up information on the implants.

  14. Effects of dynamic loading of motor-operated valve actuators

    International Nuclear Information System (INIS)

    Damerell, P.S.; Daubresse, S.; Wolfe, K.J.; Dogan, T.; Gleeson, J.

    1994-01-01

    Experience has shown that valves with rising, nonrotating stems that are operated using electro-motor driven actuators can be susceptible to changes in output thrust at a constant torque switch setting as a result of changes in stem load time history. This effect is a concern because tests on these types of valves to verify thrust achieved at torque switch trip are often performed in situ under load conditions different from the required performance conditions. As part of a motor-operated valve research program being carried out by the Electric Power Research Institute, tests of typical electric motor actuators used with nuclear services valves have been performed. The test results show that changes in output thrust with load time history occur o varying degrees on different stem and stem nut combinations. When the effect exists, there is generally an increase in thrust at torque switch trip when load is developed rapidly from low initial loads, compared to when load is developed slowly. The effect is mainly a result of changes in the coefficient of friction at the stem-stem nut interface. The coefficient of friction is temporarily reduced under rapid loading conditions from low initial load, leading to increased thrust. The root cause is hypothesized to be a open-quotes squeeze-filmclose quotes effect, whereby mixed-mode lubrication (hydrodynamic plus boundary) temporarily replaces boundary lubrication. This paper describes the results of tests performed to better understand the phenomenon

  15. Valve for closing a steam line

    International Nuclear Information System (INIS)

    Meyer, W.; Potrykus, G.

    1976-01-01

    Instead of several control elements, the quick-closing valve, especially in the main-steam line between steam generator and turbine of a power station has the valve cone itself as the only movable part, acting with its inner surface as a piston within a second cylinder space. The valve shaft is at the same time a piston rod with a stepped piston at the upper end. This piston is loaded in a cylinder at the upspace below the valve cover on one hand by a spring, on the other hand by its own medium. Two non-return valves, one of it in a bore of the valve cone, connect the first-mentioned cylinder space with the steam-loaded inlet resp. outlet side of the valve. For controlling the valve, a magnet valve is sufficient. By automatic control of the valve cone coupled with several pistons several control lines can be omitted. There are also no pressurized control lines outside the valve which could be damaged by exterior influences. (ERA) [de

  16. Carotenoids co-localize with hydroxyapatite, cholesterol, and other lipids in calcified stenotic aortic valves. Ex vivo Raman maps compared to histological patterns

    Directory of Open Access Journals (Sweden)

    A. Bonetti

    2015-04-01

    Full Text Available Unlike its application for atherosclerotic plaque analysis, Raman microspectroscopy was sporadically used to check the sole nature of bioapatite deposits in stenotic aortic valves, neglecting the involvement of accumulated lipids/lipoproteins in the calcific process. Here, Raman microspectroscopy was employed for examination of stenotic aortic valve leaflets to add information on nature and distribution of accumulated lipids and their correlation with mineralization in the light of its potential precocious diagnostic use. Cryosections from surgically explanted stenotic aortic valves (n=4 were studied matching Raman maps against specific histological patterns. Raman maps revealed the presence of phospholipids/triglycerides and cholesterol, which showed spatial overlapping with one another and Raman-identified hydroxyapatite. Moreover, the Raman patterns correlated with those displayed by both von-Kossa-calcium- and Nile-blue-stained serial cryosections. Raman analysis also provided the first identification of carotenoids, which co-localized with the identified lipid moieties. Additional fit concerned the distribution of collagen and elastin. The good correlation of Raman maps with high-affinity staining patterns proved that Raman microspectroscopy is a reliable tool in evaluating calcification degree, alteration/displacement of extracellular matrix components, and accumulation rate of different lipid forms in calcified heart valves. In addition, the novel identification of carotenoids supports the concept that valve stenosis is an atherosclerosis-like valve lesion, consistently with their previous Raman microspectroscopical identification inside atherosclerotic plaques.

  17. Carotenoids co-localize with hydroxyapatite, cholesterol, and other lipids in calcified stenotic aortic valves. Ex vivo Raman maps compared to histological patterns.

    Science.gov (United States)

    Bonetti, A; Bonifacio, A; Della Mora, A; Livi, U; Marchini, M; Ortolani, F

    2015-04-20

    Unlike its application for atherosclerotic plaque analysis, Raman microspectroscopy was sporadically used to check the sole nature of bioapatite deposits in stenotic aortic valves, neglecting the involvement of accumulated lipids/lipoproteins in the calcific process. Here, Raman microspectroscopy was employed for examination of stenotic aortic valve leaflets to add information on nature and distribution of accumulated lipids and their correlation with mineralization in the light of its potential precocious diagnostic use. Cryosections from surgically explanted stenotic aortic valves (n=4) were studied matching Raman maps against specific histological patterns. Raman maps revealed the presence of phospholipids/triglycerides and cholesterol, which showed spatial overlapping with one another and Raman-identified hydroxyapatite. Moreover, the Raman patterns correlated with those displayed by both von-Kossa-calcium- and Nile-blue-stained serial cryosections. Raman analysis also provided the first identification of carotenoids, which co-localized with the identified lipid moieties. Additional fit concerned the distribution of collagen and elastin. The good correlation of Raman maps with high-affinity staining patterns proved that Raman microspectroscopy is a reliable tool in evaluating calcification degree, alteration/displacement of extracellular matrix components, and accumulation rate of different lipid forms in calcified heart valves. In addition, the novel identification of carotenoids supports the concept that valve stenosis is an atherosclerosis-like valve lesion, consistently with their previous Raman microspectroscopical identification inside atherosclerotic plaques.

  18. SEBIM pilot operated tandems. A new solution for Darlington NGS bleed condenser relief valves

    International Nuclear Information System (INIS)

    Paetzold, H.; Hera, V.; Schaumburg, G.

    1996-01-01

    Following incidents at Pickering, Wolsung and Bruce NGS, involving instability of bleed condenser relief valves, Darlington station decided to replace the spring loaded RV's by new pilot operated SEBIM tandem valves. This paper is presenting the approach taken, the design and the testing of the new solution, as well as some of the computer modeling work performed in connection with this project. The SEBIM tandems, following successful testing in France, will be installed in Darlington Unit 2, this spring. The new valves can perform with absence of instability and prevent a LOCA incident due to their design, which includes a protection and a redundant valve in series. (author)

  19. 3D capillary valves for versatile capillary patterning of channel walls

    NARCIS (Netherlands)

    Papadimitriou, Vasileios; van den Berg, Albert; Eijkel, Jan C.T.

    2016-01-01

    We demonstrate passive capillary patterning of channel walls with a liquid in situ. Patterning is performed using a novel 3D capillary valve system combining three standard capillary stop valves. A range of different patterns is demonstrated in three channel walls. Capillary patterning was designed

  20. Door valve for fuel handling path

    International Nuclear Information System (INIS)

    Makishima, Katsuhiko.

    1969-01-01

    A door valve is provided which seals cover gas from a liquid metal cooled reactor without leakage therefrom. A threaded shaft is screwed into a heavy box press which is packed with lead. The shaft is adapted to be rotated by an electric motor or a manually operated wheel which is disposed outside of the door valve. From the box press a valve plate is suspended by four linkage bars, one for each corner. Each linkage bar is provided with two wheels which are respectively mounted at the connections with the box press and the valve plate. The wheels are carried on the horizontal grooves formed in a door valve casing. In operation the shaft rotates and travels to permit the box press and the valve plate to move into the door valve casing while the valve plate does not contact the casing. When the box press reaches the home position, the wheels drop into the recesses which are disposed at the ends of the grooves, the valve plate is carried on the valve opening, and the box press presses the valve plate to increase the tightness. The valve plate does not suffer wear as it does not over other parts. (Yamaguchi, T.)