WorldWideScience

Sample records for channel plate mcp

  1. Systematic studies of micro-channel plate PMTs

    International Nuclear Information System (INIS)

    Lehmann, A.; Britting, A.; Cowie, E.; Dodokhof, V.Kh.; Dueren, M.; Dutta, D.; Eyrich, W.; Foehl, K.; Glazier, D.I.; Hayrapetyan, A.; Hoek, M.; Hohler, R.; Kaiser, R.; Keri, T.; Koch, P.; Kroeck, B.; Lehmann, D.; Marton, J.; Merle, O.; Montgomery, R.

    2011-01-01

    DIRC Cherenkov detectors will be the main devices for π/K separation at the PANDA experiment at FAIR. Due to their advantageous properties in terms of time resolution and especially inside magnetic fields micro-channel plate photo multipliers (MCP-PMTs) are very attractive sensor candidates. In this paper we present the investigation of several types of multi-anode MCP-PMTs. The darkcount rate, the behavior inside a magnetic field of up to 2 T, the time resolution, the gain homogeneity and crosstalk of multi-pixel MCP-PMTs were found to be well suitable for the PANDA requirements. Even the rate capability of the latest models from Burle-Photonis and Hamamatsu is satisfactory. Although a big step forward was accomplished with these recently available MCP-PMTs, the lifetime is still not sufficient for the photon densities expected for the PANDA DIRCs.

  2. Observation of Ultra-Slow Antiprotons using Micro-channel Plate

    Science.gov (United States)

    Imao, H.; Torii, H. A.; Nagata, Y.; Toyoda, H.; Shimoyama, T.; Enomoto, Y.; Higaki, H.; Kanai, Y.; Mohri, A.; Yamazaki, Y.

    2008-08-01

    Our group ASACUSA-MUSASHI has succeeded in accumulating several million antiprotons and extracting them as monochromatic ultra-slow antiproton beams (10 eV-1 keV) at CERN AD. We have observed ultra-slow antiprotons using micro-channel plates (MCP). The integrated pulse area of the output signals generated when the MCP was irradiated by ultra-slow antiprotons was 6 times higher than that by electrons. As a long-term effect, we also observed an increase in the background rate presumably due to the radioactivation of the MCP surface. Irradiating the antiproton beams on the MCP induces antiproton-nuclear annihilations only on the first layer of the surface. Low-energy and short-range secondary particles like charged nuclear fragments caused by the "surface nuclear reactions" would be the origin of our observed phenomena.

  3. Effect of nano-scale morphology on micro-channel wall surface and electrical characterization in lead silicate glass micro-channel plate

    Science.gov (United States)

    Cai, Hua; Li, Fangjun; Xu, Yanglei; Bo, Tiezhu; Zhou, Dongzhan; Lian, Jiao; Li, Qing; Cao, Zhenbo; Xu, Tao; Wang, Caili; Liu, Hui; Li, Guoen; Jia, Jinsheng

    2017-10-01

    Micro-channel plate (MCP) is a two dimensional arrays of microscopic channel charge particle multiplier. Silicate composition and hydrogen reduction are keys to determine surface morphology of micro-channel wall in MCP. In this paper, lead silicate glass micro-channel plates in two different cesium contents (0at%, 0.5at%) and two different hydrogen reduction temperatures (400°C,450°C) were present. The nano-scale morphology, elements content and chemical states of microporous wall surface treated under different alkaline compositions and reduction conditions was investigated by Atomic Force Microscopy (AFM) and X-ray Photoelectron Spectroscopy (XPS), respectively. Meanwhile, the electrical characterizations of MCP, including the bulk resistance, electron gain and the density of dark current, were measured in a Vacuum Photoelectron Imaging Test Facility (VPIT).The results indicated that the granular phase occurred on the surface of microporous wall and diffuses in bulk glass is an aggregate of Pb atom derived from the reduction of Pb2+. In micro-channel plate, the electron gain and bulk resistance were mainly correlated to particle size and distribution, the density of dark current (DDC) went up with the increasing root-mean-square roughness (RMS) on the microporous wall surface. Adding cesiums improved the size of Pb atomic aggregation, lowered the relative concentration of [Pb] reduced from Pb2+ and decreased the total roughness of micro-channel wall surface, leading a higher bulk resistance, a lower electron gain and a less dark current. Increasing hydrogen reduction temperature also improved the size of Pb atomic aggregation, but enhanced the relative concentration of [Pb] and enlarged the total roughness of micro-channel wall surface, leading a higher bulk resistance, a lower electron gain and a larger dark current. The reasons for the difference of electrical characteristics were discussed.

  4. A novel ZVS high voltage power supply for micro-channel plate photomultiplier tubes

    International Nuclear Information System (INIS)

    Pei, Chengquan; Tian, Jinshou; Liu, Zhen; Qin, Hong; Wu, Shengli

    2017-01-01

    A novel resonant high voltage power supply (HVPS) with zero voltage switching (ZVS), to reduce the voltage stress on switching devices and improve conversion efficiency, is proposed. The proposed HVPS includes a drive circuit, a transformer, several voltage multiplying circuits, and a regulator circuit. The HVPS contains several secondary windings that can be precisely regulated. The proposed HVPS performed better than the traditional resistor voltage divider, which requires replacing matching resistors resulting in resistor dispersibility in the Micro-Channel Plate (MCP). The equivalent circuit of the proposed HVPS was established and the operational principle analyzed. The entire switching element can achieve ZVS, which was validated by a simulation and experiments. The properties of this HVPS were tested including minimum power loss (240 mW), maximum power loss (1 W) and conversion efficiency (85%). The results of this research are that the proposed HVPS was suitable for driving the micro-channel plate photomultiplier tube (MCP-PMT). It was therefore adopted to test the MCP-PMT, which will be used in Daya Bay reactor neutrino experiment II in China.

  5. A novel ZVS high voltage power supply for micro-channel plate photomultiplier tubes

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Chengquan [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); Tian, Jinshou [Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); Liu, Zhen [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); Qin, Hong [School of Computer Science and Technology, Xi' an University of Science and Technology, Xi' an 710054 (China); Wu, Shengli, E-mail: slwu@mail.xjtu.edu.cn [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China)

    2017-04-11

    A novel resonant high voltage power supply (HVPS) with zero voltage switching (ZVS), to reduce the voltage stress on switching devices and improve conversion efficiency, is proposed. The proposed HVPS includes a drive circuit, a transformer, several voltage multiplying circuits, and a regulator circuit. The HVPS contains several secondary windings that can be precisely regulated. The proposed HVPS performed better than the traditional resistor voltage divider, which requires replacing matching resistors resulting in resistor dispersibility in the Micro-Channel Plate (MCP). The equivalent circuit of the proposed HVPS was established and the operational principle analyzed. The entire switching element can achieve ZVS, which was validated by a simulation and experiments. The properties of this HVPS were tested including minimum power loss (240 mW), maximum power loss (1 W) and conversion efficiency (85%). The results of this research are that the proposed HVPS was suitable for driving the micro-channel plate photomultiplier tube (MCP-PMT). It was therefore adopted to test the MCP-PMT, which will be used in Daya Bay reactor neutrino experiment II in China.

  6. Mean secondary electron yield of avalanche electrons in the channels of a microchannel plate detector

    International Nuclear Information System (INIS)

    Funsten, H.O.; Suszcynsky, D.M.; Harper, R.W.

    1996-01-01

    By modeling the statistical evolution of an avalanche created by 20 keV protons impacting the input surface of a z-stack microchannel plate (MCP) detector, the mean secondary electron yield γ C of avalanche electrons propagating through a MCP channel is measured to equal 1.37 for 760 V per MCP in the z stack. This value agrees with other studies that used MCP gain measurements to infer γ C . The technique described here to measure γ C is independent of gain saturation effects and simplifying assumptions used in the segmented dynode model, both of which can introduce errors when inferring γ C through gain measurements. copyright 1996 American Institute of Physics

  7. Studies of MCP properties

    International Nuclear Information System (INIS)

    Lehmann, A; Britting, A; Eyrich, W; Uhlig, F

    2009-01-01

    Cherenkov detectors of the DIRC type will be used for the particle identification of the PANDA experiment at FAIR. Because of their advantageous properties inside a magnetic field micro-channel plate (MCP) photomultipliers (PMT) are very attractive photon sensors for the two PANDA DIRCs. Various types of MCP-PMTs were investigated. Their gains and their time resolutions were measured as a function of the magnitude and the direction of a magnetic field. It was found that with a pore size of ≤ 10 μm efficient single photon detection is possible even at 2 Tesla if the field direction is close to parallel to the PMT axis. The gain of most of the studied MCP-PMTs remains stable up to a photon density of roughly 1 MHz/cm 2 , while the new Hamamatsu R10754-00-L4 can stand rates of about 10 MHz/cm 2 before the gain starts decreasing. The time resolution of all investigated MCP-PMTs was better than 50 ps (σ). The response of the multi-anode MCP-PMTs was scanned as a function of the position of the photo cathode plane in particular to measure the crosstalk among adjacent pixels. Most of the sensors show a satisfactory behavior.

  8. Silicon-micromachined microchannel plates

    International Nuclear Information System (INIS)

    Beetz, Charles P.; Boerstler, Robert; Steinbeck, John; Lemieux, Bryan; Winn, David R.

    2000-01-01

    Microchannel plates (MCP) fabricated from standard silicon wafer substrates using a novel silicon micromachining process, together with standard silicon photolithographic process steps, are described. The resulting SiMCP microchannels have dimensions of ∼0.5 to ∼25 μm, with aspect ratios up to 300, and have the dimensional precision and absence of interstitial defects characteristic of photolithographic processing, compatible with positional matching to silicon electronics readouts. The open channel areal fraction and detection efficiency may exceed 90% on plates up to 300 mm in diameter. The resulting silicon substrates can be converted entirely to amorphous quartz (qMCP). The strip resistance and secondary emission are developed by controlled depositions of thin films, at temperatures up to 1200 deg. C, also compatible with high-temperature brazing, and can be essentially hydrogen, water and radionuclide-free. Novel secondary emitters and cesiated photocathodes can be high-temperature deposited or nucleated in the channels or the first strike surface. Results on resistivity, secondary emission and gain are presented

  9. Single ion counting with a MCP (microchannel plate) detector

    Energy Technology Data Exchange (ETDEWEB)

    Tawara, Hiroko; Sasaki, Shinichi; Miyajima, Mitsuhiro [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan); Shibamura, Eido

    1996-07-01

    In this study, a single-ion-counting method using alpha-particle-impact ionization of Ar atoms is demonstrated and the preliminary {epsilon}{sub mcp} for Ar ions with incident energies of 3 to 4.7 keV is determined. The single-ion counting by the MCP is aimed to be performed under experimental conditions as follows: (1) A signal from the MCP is reasonably identified as incidence of single Ar-ion. (2) The counting rate of Ar ions is less than 1 s{sup -1}. (3) The incident Ar ions are not focused on a small part of an active area of the MCP, namely, {epsilon}{sub mcp} is determined with respect to the whole active area of the MCP. So far, any absolute detection efficiency has not been reported under these conditions. (J.P.N.)

  10. Multiple-photon disambiguation on stripline-anode Micro-Channel Plates

    Energy Technology Data Exchange (ETDEWEB)

    Jocher, Glenn R., E-mail: glenn.jocher@ultralytics.com [Ultralytics LLC, Arlington, VA 22203 (United States); Wetstein, Matthew J., E-mail: mwetstein@uchicago.edu [Iowa State University, Department of Physics and Astronomy, 12 Physics Hall, Ames, IA 50011 (United States); Adams, Bernhard, E-mail: badams@incomusa.com [Incom, Inc., 294 Southbridge Road, Charlton, MA 01507 (United States); Nishimura, Kurtis, E-mail: kurtis.nishimura@ultralytics.com [Ultralytics LLC, Arlington, VA 22203 (United States); Usman, Shawn M., E-mail: shawn.usman@nga.mil [Research Directorate, National Geospatial-Intelligence Agency, 7500 GEOINT Dr., Springfield, VA 22150 (United States); Department of Geography and Geoinformation Science, George Mason University, Fairfax, VA 22030 (United States)

    2016-06-21

    Large-Area Picosecond Photo-Detectors (LAPPDs) show great potential for expanding the performance envelope of Micro-Channel Plates (MCPs) to areas of up to 20×20 cm and larger. Such scaling introduces new challenges, including how to meet the electronics readout burden of ever larger area MCPs. One solution is to replace the traditional grid anode used for readout with a microwave stripline anode, thus allowing the channel count to scale with MCP width rather than area. However, stripline anodes introduce new issues not commonly dealt with in grid-anodes, especially as their length increases. One of these issues is the near simultaneous arrival of multiple photons on the detector, creating possible confusion about how to reconstruct their arrival times and positions. We propose a maximum a posteriori solution to the problem and verify its performance in simulated scintillator and water-Cherenkov detectors.

  11. Batch production of microchannel plate photo-multipliers

    Energy Technology Data Exchange (ETDEWEB)

    Frisch, Henry J.; Wetstein, Matthew; Elagin, Andrey

    2018-03-06

    In-situ methods for the batch fabrication of flat-panel micro-channel plate (MCP) photomultiplier tube (PMT) detectors (MCP-PMTs), without transporting either the window or the detector assembly inside a vacuum vessel are provided. The method allows for the synthesis of a reflection-mode photocathode on the entrance to the pores of a first MCP or the synthesis of a transmission-mode photocathode on the vacuum side of a photodetector entrance window.

  12. Efficiency enhancements for MCP-based beta autoradiography imaging

    CERN Document Server

    Lees, J E

    2002-01-01

    We describe three approaches to increase the beta detection efficiency of microchannel plate detectors for biological beta autoradiography:(a)reversing the microchannel plate (MCP) bias polarity, changing the conventional high negative voltage on the input MCP to a grounded input, (b) a reduction in MCP pore size from 12.5 to 6 mu m, (c) using a CsI coating as an efficient secondary electron emitter. We also present our first measurements of double-tracer ( sup 3 H and sup 1 sup 4 C) imaging using pulse height analysis to distinguish between isotopes.

  13. MCP characterization at the Cu and Mo Kα x-ray energies

    International Nuclear Information System (INIS)

    Walsh, P.J.; Evans, S.; Schappert, G.T.; Kyrala, G.A.

    1998-03-01

    The authors are investigating the usefulness of microchannel plate (MCP) intensifiers for imaging x-rays at high photon energies, specifically by using filtered X-rays from an electron bombardment source to generate the K α lines of Cu at 8.04 KeV and Mo at 17.5 KeV. These high energy lines are used to measure the resolution of an MCP based intensifier produced at Los Alamos National Laboratory. They have investigated the spot size of a fielded MCP intensifier by observing, on film, the result of single photon excitation of microchannels. Measurement of the spot size was done with visible light microscopy. They report initial results of the spot size distribution in the stripline direction. They have also begun a measurement of the azimuthal anisotropy in the spatial resolution, accentuated at these energies by the inclination of the axis of the MCP channels. They concentrate on an actual ''fielded instrument'' resolution, rather than ideal, for the purpose of analyzing image data captured at the NOVA Laser Facility

  14. Transmission-Line Readout with Good Time and Space Resolutions for Planacon MCP-PMTs

    CERN Document Server

    Tang, F; Byrum, K; Drake, G; Ertley, C; Frisch, H; Genat, J-F; May, E

    2008-01-01

    With commercially-available multi-anode microchannel plate photomultiplier tubes (MCP-PMT) and electronics, resolutions significantly better than 10 psec have been achieved in small systems with a few readout channels[1,2]. For large-scale time-of-flight systems used in particle physics, which may cover tens of square meters, a solution must be found with a manageable number of electronics channels and low total power consumption on the readout electronics without degrading the system timing resolution. We present here the design of a transmission-line readout for a Photonis Planacon MCP-PMT that has these characteristics. The tube, which is 5 cm square, is characterized by signal pulse rise times in the order of 200 psec and transit time spreads (TTS) in the order of 25 psec[1, 2]. The model 85011-011 MCP has 1024 anode pads laid out in an array of 32 by 32 on the back of the tube. The proposed readout is implemented on a Rogers 4350B printed circuit board with 32 parallel 50-ohm transmission lines on 1.6 mm...

  15. Developments in microchannel plate detectors for imaging x-ray astronomy

    International Nuclear Information System (INIS)

    Fraser, G.W.; Whiteley, M.J.; Pearson, J.F.

    1985-01-01

    The authors present new results in four areas of microchannel plate (MCP) X-ray detector operation. The performance in pulse counting mode of MCPs with 8 micron channel diameters is reported. The effects on MCP quantum detection efficiency and energy discrimination of multiple CsI coatings are described. A new mode of operation of two-stage multipliers is evaluated. Replacing the conventional electron-accelerating inter-plate potential difference by a retarding field is shown to result in definite advantages with regard to X-ray energy discrimination and detector lifetime. The source of the MCP internal background is discussed

  16. Silicon-micromachined microchannel plates

    CERN Document Server

    Beetz, C P; Steinbeck, J; Lemieux, B; Winn, D R

    2000-01-01

    Microchannel plates (MCP) fabricated from standard silicon wafer substrates using a novel silicon micromachining process, together with standard silicon photolithographic process steps, are described. The resulting SiMCP microchannels have dimensions of approx 0.5 to approx 25 mu m, with aspect ratios up to 300, and have the dimensional precision and absence of interstitial defects characteristic of photolithographic processing, compatible with positional matching to silicon electronics readouts. The open channel areal fraction and detection efficiency may exceed 90% on plates up to 300 mm in diameter. The resulting silicon substrates can be converted entirely to amorphous quartz (qMCP). The strip resistance and secondary emission are developed by controlled depositions of thin films, at temperatures up to 1200 deg. C, also compatible with high-temperature brazing, and can be essentially hydrogen, water and radionuclide-free. Novel secondary emitters and cesiated photocathodes can be high-temperature deposite...

  17. TOF-SIMA analysis of coating on MCP

    International Nuclear Information System (INIS)

    Luo Chunping; Liang Handong; Sun Dongxu

    2007-01-01

    Microchannel plate (MCP) is a sophisticated electronic optical device. It has advantages of high gain, small size, and low using voltage as a detector. The electronic transmission film on the MCP input plane could effectively avoid the positive ion feedback, and protect the photocathode, eliminate flicker noise, and prolong the lifespan of the device. In conclusion, the different films of the input plane can affect the performance of the MCP. Therefore, there is practical value to study surface coating composition of MCP for understanding the relationship between composition and performance and developing high-powered MCP. In the experiment, TOF-SIMS is used to study the surface coating composition of MCP. The results show that there are some main metal elements such as Si, K, Cr, Ni, Rh, Cs and Pb in the surface of the MCP. (authors)

  18. Gain stabilized microchannel plates and a treatment method for microchannel plates

    International Nuclear Information System (INIS)

    1979-01-01

    Microchannel plates having increased gain and significantly improved aging characteristics are provided by forming a thin film of a cesium compound on the channel walls. In an exemplary embodiment, a suface film of cesium hydroxide is applied to the interior wall surfaces of an MCP by saturating the plate with a solution of the compound, then allowing the solvent to evaporate. The cesium hydroxide residue on the walls subsequently is converted to cesium oxide by a high temperature bake. Microchannel plates are used in image amplifiers, radiation detectors and such like equipment. (Auth.)

  19. Temporal resolution technology of a soft X-ray picosecond framing camera based on Chevron micro-channel plates gated in cascade

    Energy Technology Data Exchange (ETDEWEB)

    Yang Wenzheng [State Key Laboratory of Transient Optics and Photonics, Xi' an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China)], E-mail: ywz@opt.ac.cn; Bai Yonglin; Liu Baiyu [State Key Laboratory of Transient Optics and Photonics, Xi' an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); Bai Xiaohong; Zhao Junping; Qin Junjun [Key Laboratory of Ultra-fast Photoelectric Diagnostics Technology, Xi' an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China)

    2009-09-11

    We describe a soft X-ray picosecond framing camera (XFC) based on Chevron micro-channel plates (MCPs) gated in cascade for ultra-fast process diagnostics. The micro-strip lines are deposited on both the input and the output surfaces of the Chevron MCPs and can be gated by a negative (positive) electric pulse on the first (second) MCP. The gating is controlled by the time delay T{sub d} between two gating pulses. By increasing T{sub d}, the temporal resolution and the gain of the camera are greatly improved compared with a single-gated MCP-XFC. The optimal T{sub d}, which results in the best temporal resolution, is within the electron transit time and transit time spread of the MCP. Using 250 ps, {+-}2.5 kV gating pulses, the temporal resolution of the double-gated Chevron MCPs camera is improved from 60 ps for the single-gated MCP-XFC to 37 ps for T{sub d}=350 ps. The principle is presented in detail and accompanied with a theoretic simulation and experimental results.

  20. Ion Feedback Suppression Using Inclined MCP Holes in a Single-MCP+Micromegas+Pads Detector

    International Nuclear Information System (INIS)

    Va'vra, J.; Sumiyoshi, T.

    2005-01-01

    We show that the ion backflow to photocathode can be completely suppressed if one uses inclined MCP holes in a presence of magnetic field. The inclined hole angles are chosen to be aligned with the Lorentz electron angle allowing the electron transmission and amplification, while positive ions, traveling along a different angle, are caught on the MCP hole walls. The detector under investigation is a new gaseous detector structure based on a tandem of two parts, a single MCP (Microchannel) plate, a Micromegas with pad readout. We are aiming to develop a gaseous photon detector with the Bialkali photocathode, however, one could use some ideas in the paper for other types of detectors

  1. Ion feedback suppression using inclined MCP holes in a 'single-MCP+micromegas+pads' detector

    International Nuclear Information System (INIS)

    Va'vra, J.; Sumiyoshi, T.

    2005-01-01

    We show that the ion backflow to photocathode can be completely suppressed if one uses inclined MCP holes in the presence of a magnetic field. The inclined hole angles are chosen to be aligned with the Lorentz electron angle allowing the electron transmission and amplification, while positive ions, traveling along a different angle, are caught on the MCP hole walls. The detector under investigation is a new gaseous detector structure based on a tandem of two parts, a single MCP (microchannel plate), a micromegas with pad readout. We are aiming to develop a gaseous photon detector with the Bialkali photocathode, however, one could use some ideas in the paper for other types of detectors

  2. New technique for radiation detection by instruments based on microchannel plates

    International Nuclear Information System (INIS)

    Ammosov, V.V.; Bolozdynya, A.I.; Kubantsev, M.A.; Lebedenko, V.N.; Suvorov, A.L.

    1986-01-01

    Coordinate information can be obtained directly from microchanel plates (MCP) as storage matrix in MCP based radiation detectors, which is proved using as an example the registering of pulsed laser ultraviolet radiation. For read-out and representation of the information the TV channel was used: the vidicon electron-optical system - TV transmission camera - TV monitor

  3. Micro-channel plate detector for ultra-fast relativistic electron diffraction

    International Nuclear Information System (INIS)

    Musumeci, P.; Moody, J.T.; Scoby, C.M.; Gutierrez, M.S.; Bender, H.A.; Hilko, B.; Kruschwitz, C.A.; Wilcox, N.S.

    2011-01-01

    Using relativistic ultra-short electron beams to obtain single-shot diffraction patterns holds the promise to yield real-time resolution of atomic motion in an easily accessible environment, such as a university laboratory, at a fraction of the cost of fourth-generation X-ray sources. One of the main issues in bringing this technique to full maturity is the development of efficient detector systems to record the diffraction pattern using a few MeV electron beams. Low noise, high spatial resolution, and single-electron detection capability are all characteristics of an ideal detector. In this paper, we compare the performances of a traditional fluorescent phosphor screen with a detection system based on the micro-channel plate (MCP). Since MCPs are typically used with lower energy electron beams, these tests constitute one of the few experimental data points available on the use of these devices with MeV energy beams.

  4. Micro-channel plate detector for ultra-fast relativistic electron diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Musumeci, P., E-mail: musumeci@physics.ucla.edu [UCLA Department of Physics and Astronomy, 475 Portola Plaza, Los Angeles, CA, 90095-1547 (United States); Moody, J.T.; Scoby, C.M.; Gutierrez, M.S. [UCLA Department of Physics and Astronomy, 475 Portola Plaza, Los Angeles, CA, 90095-1547 (United States); Bender, H.A.; Hilko, B.; Kruschwitz, C.A.; Wilcox, N.S. [National Security Technologies, LLC, Los Alamos Operations, Los Alamos, NM (United States)

    2011-05-01

    Using relativistic ultra-short electron beams to obtain single-shot diffraction patterns holds the promise to yield real-time resolution of atomic motion in an easily accessible environment, such as a university laboratory, at a fraction of the cost of fourth-generation X-ray sources. One of the main issues in bringing this technique to full maturity is the development of efficient detector systems to record the diffraction pattern using a few MeV electron beams. Low noise, high spatial resolution, and single-electron detection capability are all characteristics of an ideal detector. In this paper, we compare the performances of a traditional fluorescent phosphor screen with a detection system based on the micro-channel plate (MCP). Since MCPs are typically used with lower energy electron beams, these tests constitute one of the few experimental data points available on the use of these devices with MeV energy beams.

  5. Micro-channel plates and vacuum detectors

    Energy Technology Data Exchange (ETDEWEB)

    Gys, T., E-mail: Thierry.Gys@cern.ch

    2015-07-01

    A micro-channel plate is an array of miniature electron multipliers that are each acting as a continuous dynode chain. The compact channel structure results in high spatial and time resolutions and robustness to magnetic fields. Micro-channel plates have been originally developed for night vision applications and integrated as an amplification element in image intensifiers. These devices show single-photon sensitivity with very low noise and have been used as such for scintillating fiber tracker readout in high-energy physics experiments. Given their very short transit time spread, micro-channel plate photomultiplier tubes are also being used in time-of-flight and particle identification detectors. The present paper will cover the history of the micro-channel plate development, basic features, and some of their applications. Emphasis will be put on various new manufacturing processes that have been developed over the last few years, and that result in a significant improvement in terms of efficiency, noise, and lifetime performance.

  6. Monte Carlo Simulations of High-speed, Time-gated MCP-based X-ray Detectors: Saturation Effects in DC and Pulsed Modes and Detector Dynamic Range

    International Nuclear Information System (INIS)

    Kruschwitz, Craig; Ming Wu; Moy, Ken; Rochau, Greg

    2008-01-01

    We present here results of continued efforts to understand the performance of microchannel plate (MCP)-based, high-speed, gated, x-ray detectors. This work involves the continued improvement of a Monte Carlo simulation code to describe MCP performance coupled with experimental efforts to better characterize such detectors. Our goal is a quantitative description of MCP saturation behavior in both static and pulsed modes. We have developed a new model of charge buildup on the walls of the MCP channels and measured its effect on MCP gain. The results are compared to experimental data obtained with a short-pulse, high-intensity ultraviolet laser; these results clearly demonstrate MCP saturation behavior in both DC and pulsed modes. The simulations compare favorably to the experimental results. The dynamic range of the detectors in pulsed operation is of particular interest when fielding an MCP-based camera. By adjusting the laser flux we study the linear range of the camera. These results, too, are compared to our simulations

  7. A Design of a PET Detector Using Micro-Channel Plate Photomultipliers with Transmission-Line Readout.

    Science.gov (United States)

    Kim, H; Frisch, H; Chen, C-T; Genat, J-F; Tang, F; Moses, W W; Choong, W S; Kao, C-M

    2010-01-01

    A computer simulation study has been conducted to investigate the feasibility of a positron emission tomography (PET) detector design by using micro-channel plate (MCP) photomultiplier tubes (PMT) with transmission-line (TL) read-out and waveform sampling. The detector unit consisted of a 24×24 array of pixelated LSO crystals, each of which was 4×4×25 mm(3) in size, and two 102×102 mm(2) MCP-PMTs coupled to both sides of the scintillator array. The crystal (and TL) pitch was 4.25 mm and reflective medium was inserted between the crystals. The transport of the optical photons inside the scintillator were simulated by using the Geant4 package. The output pulses of the MCP-PMT/TL unit were formed by applying the measured single photo-electron response of the MCP-PMT/TL unit to each individual photon that interacts with the photo-cathode of the MCP-PMT. The waveforms of the pulses at both ends of the TL strips were measured and analyzed to produce energy and timing information for the detected event. An experimental setup was developed by employing a Photonis Planacon MCP-PMT (XP85022) and a prototype TL board for measuring the single photo-electron response of the MCP-PMT/TL. The simulation was validated by comparing the predicted output pulses to measurements obtained with a single MCP-PMT/TL coupled to an LSO crystal exposed to 511 keV gamma rays. The validated simulation was then used to investigate the performance of the proposed new detector design. Our simulation result indicates an energy resolution of ~11% at 511 keV. When using a 400-600 keV energy window, we obtain a coincidence timing resolution of ~323 ps FWHM and a coincidence detection efficiency of ~40% for normally-incident 511keV photons. For the positioning accuracy, it is determined by the pitch of the TLs (and crystals) in the direction normal to the TLs and measured to be ~2.5 mm in the direction parallel to the TLs. The energy and timing obtained at the front- and back-end of the scintillator

  8. Amorphous silicon-based microchannel plates

    International Nuclear Information System (INIS)

    Franco, Andrea; Riesen, Yannick; Wyrsch, Nicolas; Dunand, Sylvain; Powolny, François; Jarron, Pierre; Ballif, Christophe

    2012-01-01

    Microchannel plates (MCP) based on hydrogenated amorphous silicon (a-Si:H) were recently introduced to overcome some of the limitations of crystalline silicon and glass MCP. The typical thickness of a-Si:H based MCPs (AMCP) ranges between 80 and 100 μm and the micromachining of the channels is realized by deep reactive ion etching (DRIE). Advantages and issues regarding the fabrication process are presented and discussed. Electron amplification is demonstrated and analyzed using Electron Beam Induced Current (EBIC) technique. The gain increases as a function of the bias voltage, limited to −340 V on account of high leakage currents across the structure. EBIC maps on 10° tilted samples confirm that the device active area extend to the entire channel opening. AMCP characterization with the electron beam shows gain saturation and signal quenching which depends on the effectiveness of the charge replenishment in the channel walls.

  9. Time response of fast-gated microchannel plates used as x-ray detectors

    International Nuclear Information System (INIS)

    Turner, R.E.; Bell, P.; Hanks, R.; Kilkenny, J.D.; Landen, N.; Power, G.; Wiedwald, J.; Meier, M.

    1990-01-01

    We report measurements of the time response of fast-gated, micro- channel plate (MCP) detectors, using a <10 ps pulsewidth ultra-violet laser and an electronic sampling system to measure time resolutions to better than 25 ps. The results show that framing times of less than 100 ps are attainable with high gain. The data is compared to a Monte Carlo calculation, which shows good agreement. We also measured the relative sensitivity as a function of DC bias, and saturation effects for large signal inputs. In part B, we briefly describe an electrical ''time-of-flight'' technique, which we have used to measure the response time of a fast-gated microchannel plate (MCP). Thinner MCP's than previously used have been tested, and, as expected, show fast gating times and smaller electron multiplication. A preliminary design for an x-ray pinhole camera, using a thin MCP, is presented. 7 refs., 6 figs

  10. Octanol reduces end-plate channel lifetime

    Science.gov (United States)

    Gage, Peter W.; McBurney, Robert N.; Van Helden, Dirk

    1978-01-01

    1. Post-synaptic effects of n-octanol at concentrations of 0·1-1 mM were examined in toad sartorius muscles by use of extracellular and voltage-clamp techniques. 2. Octanol depressed the amplitude and duration of miniature end-plate currents and hence depressed neuromuscular transmission. 3. The decay of miniature end-plate currents remained exponential in octanol solutions even when the time constant of decay (τD) was decreased by 80-90%. 4. The lifetime of end-plate channels, obtained by analysis of acetylcholine noise, was also decreased by octanol. The average lifetime measured from noise spectra agreed reasonably well with the time constant of decay of miniature end-plate currents, both in control solution and in octanol solutions. 5. Octanol caused a reduction in the conductance of end-plate channels. Single channel conductance was on average about 25 pS in control solution and 20 pS in octanol. 6. In most cells the normal voltage sensitivity of the decay of miniature end-plate currents was retained in octanol solutions. The lifetime of end-plate channels measured from acetylcholine noise also remained voltage-sensitive in octanol solutions. In some experiments in which channel lifetime was exceptionally reduced the voltage sensitivity was less than normal. 7. In octanol solutions, τD was still very sensitive to temperature changes in most cells although in some the temperature sensitivity of τD was clearly reduced. Changes in τD with temperature could generally be fitted by the Arrhenius equation suggesting that a single step reaction controlled the decay of currents both in control and in octanol solutions. In some cells in which τD became less than 0·3 ms, the relationship between τD and temperature became inconsistent with the Arrhenius equation. 8. As the decay of end-plate currents in octanol solutions remains exponential, and the voltage and temperature sensitivity can be unchanged even when τD is significantly reduced, it seems likely that

  11. Single electron counting using a dual MCP assembly

    International Nuclear Information System (INIS)

    Yang, Yuzhen; Liu, Shulin; Zhao, Tianchi; Yan, Baojun; Wang, Peiliang; Yu, Yang; Lei, Xiangcui; Yang, Luping; Wen, Kaile; Qi, Ming

    2016-01-01

    The gain, pulse height resolution and peak-to-valley ratio of single electrons detected by using a Chevron configured Microchannel Plate (MCP) assembly are studied. The two MCPs are separated by a 280 µm gap and are biased by four electrodes. The purpose of the study is to determine the optimum bias voltage arrangements for single electron counting. By comparing the results of various bias voltage combinations, we conclude that good performance for the electron counting can be achieved by operating the MCP assembly in saturation mode. In addition, by applying a small reverse bias voltage across the gap while adjusting the bias voltages of the MCPs, optimum performance of electron counting can be obtained. - Highlights: • Dual MCPs assembly with four electrodes using different voltage combinations has been investigated for single electron counting. • Both the MCP voltages and the gap voltage can affect the gain, pulse height resolution and P/V ratio. • A high gain of the first stage MCP, a saturation mode of the second stage MCP and an appropriately reverse gap voltage can improve the resolution greatly. • The optimum voltage arrangements is significant for the design of MCP detectors in single electron counting applications.

  12. X-ray focusing with Wolter microchannel plate optics

    CERN Document Server

    Price, G J; Beijersbergen, M W; Fraser, G W; Bavdaz, M; Boutot, J P; Fairbend, R; Flyckt, S O; Peacock, A; Tomaselli, E

    2002-01-01

    Square-pore microchannel plate (MCP) X-ray optics of the 'lobster-eye' geometry have frequently been described in the literature. We have now investigated the use of a radial channel packing geometry which, in the context of an MCP pair slumped to the correct radii of curvature, can form a conic approximation to the Wolter Type I grazing incidence X-ray optic. Such an optic can provide a large effective area with very low mass and may be ideally suited for use in applications such as planetary imaging X-ray fluorescence. We present here the results of X-ray illumination of the first such optic, fabricated by Photonis SAS, France.

  13. Measurement of 2-5 keV x-ray emission from laser-target interactions by using fluor-MCP and CsI-XRD detectors

    International Nuclear Information System (INIS)

    Lee, P.H.Y.; Tirsell, K.G.; Leipelt, G.R.; Laird, W.B.

    1981-01-01

    For inertial confinement fusion plasma diagnostics, x-ray diode (XRD) detectors using conventional cathodes are not sensitive enough to measure x-rays above approx. 1.5 keV. However, for laser driver fusion targets, x-rays in the range of 2 to 5 keV are important because of their mobility in the target. We have successfully used fluor-microchannel plate (MCP) detectors to obtain absolute x-ray measurements in the 2 to 5 keV range. Recent data obtained from experiments on the Shiva laser system are presented. In addition, designs for a variety of channels in the range using fluor-MCP and CsI-XRD's above 1.5 keV will be discussed

  14. Development of a single-photon-counting camera with use of a triple-stacked micro-channel plate.

    Science.gov (United States)

    Yasuda, Naruomi; Suzuki, Hitoshi; Katafuchi, Tetsuro

    2016-01-01

    At the quantum-mechanical level, all substances (not merely electromagnetic waves such as light and X-rays) exhibit wave–particle duality. Whereas students of radiation science can easily understand the wave nature of electromagnetic waves, the particle (photon) nature may elude them. Therefore, to assist students in understanding the wave–particle duality of electromagnetic waves, we have developed a photon-counting camera that captures single photons in two-dimensional images. As an image intensifier, this camera has a triple-stacked micro-channel plate (MCP) with an amplification factor of 10(6). The ultra-low light of a single photon entering the camera is first converted to an electron through the photoelectric effect on the photocathode. The electron is intensified by the triple-stacked MCP and then converted to a visible light distribution, which is measured by a high-sensitivity complementary metal oxide semiconductor image sensor. Because it detects individual photons, the photon-counting camera is expected to provide students with a complete understanding of the particle nature of electromagnetic waves. Moreover, it measures ultra-weak light that cannot be detected by ordinary low-sensitivity cameras. Therefore, it is suitable for experimental research on scintillator luminescence, biophoton detection, and similar topics.

  15. Experimental evaluation of the response of micro-channel plate detector to ions with 10s of MeV energies

    Science.gov (United States)

    Jeong, Tae Won; Singh, P. K.; Scullion, C.; Ahmed, H.; Kakolee, K. F.; Hadjisolomou, P.; Alejo, A.; Kar, S.; Borghesi, M.; Ter-Avetisyan, S.

    2016-08-01

    The absolute calibration of a microchannel plate (MCP) assembly using a Thomson spectrometer for laser-driven ion beams is described. In order to obtain the response of the whole detection system to the particles' impact, a slotted solid state nuclear track detector (CR-39) was installed in front of the MCP to record the ions simultaneously on both detectors. The response of the MCP (counts/particles) was measured for 5-58 MeV carbon ions and for protons in the energy range 2-17.3 MeV. The response of the MCP detector is non-trivial when the stopping range of particles becomes larger than the thickness of the detector. Protons with energies E ≳ 10 MeV are energetic enough that they can pass through the MCP detector. Quantitative analysis of the pits formed in CR-39 and the signal generated in the MCP allowed to determine the MCP response to particles in this energy range. Moreover, a theoretical model allows to predict the response of MCP at even higher proton energies. This suggests that in this regime the MCP response is a slowly decreasing function of energy, consistently with the decrease of the deposited energy. These calibration data will enable particle spectra to be obtained in absolute terms over a broad energy range.

  16. Fast front-end L0 trigger electronics for ALICE FMD-MCP tests and performance

    CERN Document Server

    Efimov, L G; Kasatkan, V; Klempt, W; Kuts, V; Lenti, V; Platanov, V; Rudge, A; Stolyarov, O I; Tsimbal, F A; Valiev, F F; Villalobos Baillie, O; Vinogradov, L I; Zhigunov, O

    1997-01-01

    We present design details and new measurements of the performance of fast electronics for the Forward Multiplicity Detector for ALICE. These detectors based on sector type Microchannel Plates (MCP) forming several disks gave the very first trigger decision in the experiment (L0). Fast passive summators integrated with the detectors are used for linear summation of up to eight isochronous signal channels from MCP pads belonging to one sector. Two types of microelectronics design thin film summators were produced. We present test results for these summators, working in the frequency range up to 1 Ghz. New low noise preamplifiers have been built to work with these summators. The new design shows a good performance with the usable frequency range extended up to 1 Ghz. An upgrade of the functional scheme for the L0 ALICE pre-trigger design is also presented.Abstract:List of figures Figure 1: ALICE L0 Trigger Front-End Electronics Functional Scheme. Figure 2: UHF design for a fast passive summator based on direct...

  17. Improved Detection System Description and New Method for Accurate Calibration of Micro-Channel Plate Based Instruments and Its Use in the Fast Plasma Investigation on NASA's Magnetospheric MultiScale Mission

    Science.gov (United States)

    Gliese, U.; Avanov, L. A.; Barrie, A. C.; Kujawski, J. T.; Mariano, A. J.; Tucker, C. J.; Chornay, D. J.; Cao, N. T.; Gershman, D. J.; Dorelli, J. C.; hide

    2015-01-01

    The Fast Plasma Investigation (FPI) on NASAs Magnetospheric MultiScale (MMS) mission employs 16 Dual Electron Spectrometers (DESs) and 16 Dual Ion Spectrometers (DISs) with 4 of each type on each of 4 spacecraft to enable fast (30 ms for electrons; 150 ms for ions) and spatially differentiated measurements of the full 3D particle velocity distributions. This approach presents a new and challenging aspect to the calibration and operation of these instruments on ground and in flight. The response uniformity, the reliability of their calibration and the approach to handling any temporal evolution of these calibrated characteristics all assume enhanced importance in this application, where we attempt to understand the meaning of particle distributions within the ion and electron diffusion regions of magnetically reconnecting plasmas. Traditionally, the micro-channel plate (MCP) based detection systems for electrostatic particle spectrometers have been calibrated using the plateau curve technique. In this, a fixed detection threshold is set. The detection system count rate is then measured as a function of MCP voltage to determine the MCP voltage that ensures the count rate has reached a constant value independent of further variation in the MCP voltage. This is achieved when most of the MCP pulse height distribution (PHD) is located at higher values (larger pulses) than the detection system discrimination threshold. This method is adequate in single-channel detection systems and in multi-channel detection systems with very low crosstalk between channels. However, in dense multi-channel systems, it can be inadequate. Furthermore, it fails to fully describe the behavior of the detection system and individually characterize each of its fundamental parameters. To improve this situation, we have developed a detailed phenomenological description of the detection system, its behavior and its signal, crosstalk and noise sources. Based on this, we have devised a new detection

  18. Experimental evaluation of the response of micro-channel plate detector to ions with 10s of MeV energies

    International Nuclear Information System (INIS)

    Jeong, Tae Won; Ter-Avetisyan, S.; Singh, P. K.; Kakolee, K. F.; Scullion, C.; Ahmed, H.; Hadjisolomou, P.; Alejo, A.; Kar, S.; Borghesi, M.

    2016-01-01

    The absolute calibration of a microchannel plate (MCP) assembly using a Thomson spectrometer for laser-driven ion beams is described. In order to obtain the response of the whole detection system to the particles’ impact, a slotted solid state nuclear track detector (CR-39) was installed in front of the MCP to record the ions simultaneously on both detectors. The response of the MCP (counts/particles) was measured for 5–58 MeV carbon ions and for protons in the energy range 2–17.3 MeV. The response of the MCP detector is non-trivial when the stopping range of particles becomes larger than the thickness of the detector. Protons with energies E ≳ 10 MeV are energetic enough that they can pass through the MCP detector. Quantitative analysis of the pits formed in CR-39 and the signal generated in the MCP allowed to determine the MCP response to particles in this energy range. Moreover, a theoretical model allows to predict the response of MCP at even higher proton energies. This suggests that in this regime the MCP response is a slowly decreasing function of energy, consistently with the decrease of the deposited energy. These calibration data will enable particle spectra to be obtained in absolute terms over a broad energy range.

  19. Experimental evaluation of the response of micro-channel plate detector to ions with 10s of MeV energies

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Tae Won; Ter-Avetisyan, S. [Center for Relativistic Laser Science, Institute of Basic Science (IBS), Gwangju 61005 (Korea, Republic of); Department of Physics and Photon Science, Gwangju Institute of Science and Technology (GIST), Gwangju 61005 (Korea, Republic of); Singh, P. K.; Kakolee, K. F. [Center for Relativistic Laser Science, Institute of Basic Science (IBS), Gwangju 61005 (Korea, Republic of); Scullion, C.; Ahmed, H.; Hadjisolomou, P.; Alejo, A.; Kar, S.; Borghesi, M. [School of Mathematics and Physics, The Queen’s University of Belfast, Belfast BT7 1NN (United Kingdom)

    2016-08-15

    The absolute calibration of a microchannel plate (MCP) assembly using a Thomson spectrometer for laser-driven ion beams is described. In order to obtain the response of the whole detection system to the particles’ impact, a slotted solid state nuclear track detector (CR-39) was installed in front of the MCP to record the ions simultaneously on both detectors. The response of the MCP (counts/particles) was measured for 5–58 MeV carbon ions and for protons in the energy range 2–17.3 MeV. The response of the MCP detector is non-trivial when the stopping range of particles becomes larger than the thickness of the detector. Protons with energies E ≳ 10 MeV are energetic enough that they can pass through the MCP detector. Quantitative analysis of the pits formed in CR-39 and the signal generated in the MCP allowed to determine the MCP response to particles in this energy range. Moreover, a theoretical model allows to predict the response of MCP at even higher proton energies. This suggests that in this regime the MCP response is a slowly decreasing function of energy, consistently with the decrease of the deposited energy. These calibration data will enable particle spectra to be obtained in absolute terms over a broad energy range.

  20. Compounded natural convection enhancement in a vertical parallel-plate channel

    Energy Technology Data Exchange (ETDEWEB)

    Andreozzi, Assunta [Dipartimento di Energetica, Termofluidodinamica Applicata e Condizionamenti Ambientali, Universita degli Studi di Napoli Federico II, Piazzale Tecchio 80, 80125 Napoli (Italy); Campo, Antonio [Department of Mechanical Engineering, The University of Vermont, 33 Colchester Ave., Burlington, VT 05405 (United States); Manca, Oronzio [Dipartimento di Ingegneria Aerospaziale e Meccanica, Seconda Universita degli Studi di Napoli, via Roma 29, Aversa (CE) 81031 (Italy)

    2008-06-15

    This paper addresses the natural convection behavior of air when heated in single vertical, parallel-plate channels. To enhance the heat transfer two passive schemes are combined: (1) an equidistant short plate is inserted at the inlet and (2) two parallel, colinear insulated plates are appended at the exit. The channel plates are symmetrically heated with a uniform heat flux. The computational procedure is made by solving the full elliptic Navier-Stokes and energy equations with the finite-volume methodology in an I-type computational domain that is much larger than the physical domain. Within the framework of a ''proof-of-concept'' the controlling Grashof number based on the heated plate height ranges between 10{sup 3} and 10{sup 6}. The numerical velocity, pressure and temperature fields are post-processed to compute the quantities of engineering interest such as the induced mass flow rate, the pressure at the channel mid-plane and the temperature along the plates. In addition, the Nusselt number and the average Nusselt number, both based on the heated plate height, are presented in graphical form. At the end, optimal channel configurations expressed in terms of the highest average Nusselt number are obtained for the pair of pre-assigned Grashof numbers. (author)

  1. Monte Carlo simulations of microchannel plate detectors I: steady-state voltage bias results

    Energy Technology Data Exchange (ETDEWEB)

    Ming Wu, Craig Kruschwitz, Dane Morgan, Jiaming Morgan

    2008-07-01

    X-ray detectors based on straight-channel microchannel plates (MCPs) are a powerful diagnostic tool for two-dimensional, time-resolved imaging and timeresolved x-ray spectroscopy in the fields of laser-driven inertial confinement fusion and fast z-pinch experiments. Understanding the behavior of microchannel plates as used in such detectors is critical to understanding the data obtained. The subject of this paper is a Monte Carlo computer code we have developed to simulate the electron cascade in a microchannel plate under a static applied voltage. Also included in the simulation is elastic reflection of low-energy electrons from the channel wall, which is important at lower voltages. When model results were compared to measured microchannel plate sensitivities, good agreement was found. Spatial resolution simulations of MCP-based detectors were also presented and found to agree with experimental measurements.

  2. Fuel cell plates with skewed process channels for uniform distribution of stack compression load

    Science.gov (United States)

    Granata, Jr., Samuel J.; Woodle, Boyd M.

    1989-01-01

    An electrochemical fuel cell includes an anode electrode, a cathode electrode, an electrolyte matrix sandwiched between electrodes, and a pair of plates above and below the electrodes. The plate above the electrodes has a lower surface with a first group of process gas flow channels formed thereon and the plate below the electrodes has an upper surface with a second group of process gas flow channels formed thereon. The channels of each group extend generally parallel to one another. The improvement comprises the process gas flow channels on the lower surface of the plate above the anode electrode and the process gas flow channels on the upper surface of the plate below the cathode electrode being skewed in opposite directions such that contact areas of the surfaces of the plates through the electrodes are formed in crisscross arrangements. Also, the plates have at least one groove in areas of the surfaces thereof where the channels are absent for holding process gas and increasing electrochemical activity of the fuel cell. The groove in each plate surface intersects with the process channels therein. Also, the opposite surfaces of a bipolar plate for a fuel cell contain first and second arrangements of process gas flow channels in the respective surfaces which are skewed the same amount in opposite directions relative to the longitudinal centerline of the plate.

  3. Simulation of the electron collection efficiency of a PMT based on the MCP coated with high secondary yield material

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Lin, E-mail: chenlin@opt.cn [State Key Laboratory of Transient Optics and Photonics, Xi' an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences (CAS), Xi' an 710119 (China); Graduate School of Chinese Academy of Sciences (CAS), Beijing 100049 (China); Xi' an Jiaotong University, Xi' an 710049 (China); Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan 030006 (China); Tian, Jinshou [State Key Laboratory of Transient Optics and Photonics, Xi' an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences (CAS), Xi' an 710119 (China); Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan 030006 (China); Zhao, Tianchi [Institute of High Energy Physics (IHEP) of CAS, Beijing 100049 (China); Liu, Chunliang [Xi' an Jiaotong University, Xi' an 710049 (China); Liu, Hulin; Wei, Yonglin; Sai, Xiaofeng [State Key Laboratory of Transient Optics and Photonics, Xi' an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences (CAS), Xi' an 710119 (China); Chen, Ping [State Key Laboratory of Transient Optics and Photonics, Xi' an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences (CAS), Xi' an 710119 (China); Graduate School of Chinese Academy of Sciences (CAS), Beijing 100049 (China); Wang, Xing; Lu, Yu [State Key Laboratory of Transient Optics and Photonics, Xi' an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences (CAS), Xi' an 710119 (China); Hui, Dandan [State Key Laboratory of Transient Optics and Photonics, Xi' an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences (CAS), Xi' an 710119 (China); Graduate School of Chinese Academy of Sciences (CAS), Beijing 100049 (China)

    2016-11-01

    Owning to the serious loss of photoelectrons striking at the input electrode of traditional microchannel plate (MCP), photoelectron collection efficiency (CE) of photomultiplier tubes based on MCP (MCP-PMTs) fluctuates around the MCP open area fraction and cannot make a breakthrough. Depositing a thin film of high secondary electron yield material on the MCP is proposed as an effective approach to improve the CE. The available simulation and experimental data to validate it, however, is sparse. In our work, a three-dimensional small area MCP model is developed in CST Studio Suite to evaluate the collection efficiencies of PMTs based on the traditional MCP and the coated one, respectively. Results predict that CE of the PMT based on the coated MCP has a significant increase and a better uniformity, which is expected to reach 100%.

  4. Micro-channel plate photon detector studies for the TORCH detector

    Energy Technology Data Exchange (ETDEWEB)

    Castillo García, L., E-mail: lucia.castillo.garcia@cern.ch [CERN, PH Department, CH-1211, Geneva 23 (Switzerland); Laboratory for High Energy Physics, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne (Switzerland); Brook, N.; Cowie, E.N.; Cussans, D. [H.H. Wills Physics Laboratory, University of Bristol, Bristol BS8 1TL (United Kingdom); Forty, R.; Frei, C. [CERN, PH Department, CH-1211, Geneva 23 (Switzerland); Gao, R. [Department of Physics, University of Oxford, Oxford OXI 3RH (United Kingdom); Gys, T. [CERN, PH Department, CH-1211, Geneva 23 (Switzerland); Harnew, N. [Department of Physics, University of Oxford, Oxford OXI 3RH (United Kingdom); Piedigrossi, D. [CERN, PH Department, CH-1211, Geneva 23 (Switzerland); Van Dijk, M. [H.H. Wills Physics Laboratory, University of Bristol, Bristol BS8 1TL (United Kingdom)

    2015-07-01

    The Time Of internally Reflected Cherenkov light (TORCH) detector is under development. Charged particle tracks passing through a 1 cm plate of quartz will generate the Cherenkov photons, and their arrival will be timed by an array of micro-channel plate photon detectors. As part of the TORCH R&D studies, commercial and custom-made micro-channel plate detectors are being characterized. The final photon detectors for this application are being produced in a three-phase program in collaboration with industry. Custom-made single-channel devices with extended lifetime have been manufactured and their performance is being systematically investigated in the laboratory. Optical studies for the preparation of beam and laboratory tests of a TORCH prototype are also underway.

  5. Optimization of the electron collection efficiency of a large area MCP-PMT for the JUNO experiment

    International Nuclear Information System (INIS)

    Chen, Lin; Tian, Jinshou; Liu, Chunliang; Wang, Yifang; Zhao, Tianchi; Liu, Hulin; Wei, Yonglin; Sai, Xiaofeng; Chen, Ping; Wang, Xing; Lu, Yu; Hui, Dandan; Guo, Lehui; Liu, Shulin; Qian, Sen; Xia, Jingkai; Yan, Baojun; Zhu, Na; Sun, Jianning; Si, Shuguang

    2016-01-01

    A novel large-area (20-inch) photomultiplier tube based on microchannel plate (MCP-PMTs) is proposed for the Jiangmen Underground Neutrino Observatory (JUNO) experiment. Its photoelectron collection efficiency C e is limited by the MCP open area fraction (A open ). This efficiency is studied as a function of the angular (θ), energy (E) distributions of electrons in the input charge cloud and the potential difference (U) between the PMT photocathode and the MCP input surface, considering secondary electron emission from the MCP input electrode. In CST Studio Suite, Finite Integral Technique and Monte Carlo method are combined to investigate the dependence of C e on θ, E and U. Results predict that C e can exceed A open , and are applied to optimize the structure and operational parameters of the 20-inch MCP-PMT prototype. C e of the optimized MCP-PMT is expected to reach 81.2%. Finally, the reduction of the penetration depth of the MCP input electrode layer and the deposition of a high secondary electron yield material on the MCP are proposed to further optimize C e .

  6. Study of the electric field inside microchannel plate multipliers

    International Nuclear Information System (INIS)

    Gatti, E.; Oba, K.; Rehak, P.

    1982-01-01

    Electric field inside high gain microchannel plate multipliers was studied. The calculations were based directly on the solution of the Maxwell equations applied to the microchannel plate (MCP) rather than on the conventional lumped RC model. The results are important to explain the performance of MCP's, (1) under a pulsed bias tension and, (2) at high rate conditions. The results were tested experimentally and a new method of MCP operation free from the positive ion feedback was demonstrated

  7. Significantly increased lifetime of recent microchannel-plate photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Britting, Alexander; Eyrich, Wolfgang; Lehmann, Albert; Uhlig, Fred [Physikalisches Institut, Universitaet Erlangen-Nuernberg (Germany)

    2013-07-01

    Micro-channel plate photo multipliers (MCP-PMT) are the favored sensors for the DIRC detectors (Detection of Internally Reflected Cherenkov Light) of the PANDA experiment. The main reasons for this are their usability in high magnetic fields of up to 2 T, a time resolution of better than σ = 50 ps and a rate capability high enough to withstand a detected photon rate of about 200 kHz cm{sup -2} at the MCP-PMTs surface, which is anticipated at the average luminosity of 2 . 10{sup 32} cm{sup -2}s{sup -1} in PANDA. Moreover, for the reconstruction of the Cherenkov angle using the planned optics for the barrel DIRC a spatial resolution of about 5 mm at the focal plane is needed. Until recently the major drawback of MCP-PMTs was their limited lifetime which was by far not sufficient to stand the integrated anode charge, which is ∼ 5 C/cm{sup 2} for the Barrel-DIRC and even more for the Disc-DIRC. However, the latest MCP prototype devices show a hugh step forward in this respect. The results of these lifetime measurements are presented. The achieved values are meanwhile close to the PANDA requirements for the Barrel-DIRC.

  8. Optimization of the electron collection efficiency of a large area MCP-PMT for the JUNO experiment

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Lin, E-mail: chenlin@opt.cn [State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences (CAS), Xi’an 710119 (China); Graduate School of Chinese Academy of Sciences (CAS), Beijing 100049 (China); Xi’an Jiaotong University, Xi’an 710049 (China); Tian, Jinshou [Graduate School of Chinese Academy of Sciences (CAS), Beijing 100049 (China); Liu, Chunliang [Xi’an Jiaotong University, Xi’an 710049 (China); Wang, Yifang; Zhao, Tianchi [Institute of High Energy Physics (IHEP) of CAS, Beijing 100049 (China); Liu, Hulin; Wei, Yonglin; Sai, Xiaofeng [Graduate School of Chinese Academy of Sciences (CAS), Beijing 100049 (China); Chen, Ping [State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences (CAS), Xi’an 710119 (China); Graduate School of Chinese Academy of Sciences (CAS), Beijing 100049 (China); Wang, Xing; Lu, Yu [Graduate School of Chinese Academy of Sciences (CAS), Beijing 100049 (China); Hui, Dandan; Guo, Lehui [State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences (CAS), Xi’an 710119 (China); Graduate School of Chinese Academy of Sciences (CAS), Beijing 100049 (China); Liu, Shulin; Qian, Sen; Xia, Jingkai; Yan, Baojun; Zhu, Na [Institute of High Energy Physics (IHEP) of CAS, Beijing 100049 (China); Sun, Jianning; Si, Shuguang [North Night Vision Technology (NNVT) CO., LTD, Nanjing 210110 (China); and others

    2016-08-11

    A novel large-area (20-inch) photomultiplier tube based on microchannel plate (MCP-PMTs) is proposed for the Jiangmen Underground Neutrino Observatory (JUNO) experiment. Its photoelectron collection efficiency C{sub e} is limited by the MCP open area fraction (A{sub open}). This efficiency is studied as a function of the angular (θ), energy (E) distributions of electrons in the input charge cloud and the potential difference (U) between the PMT photocathode and the MCP input surface, considering secondary electron emission from the MCP input electrode. In CST Studio Suite, Finite Integral Technique and Monte Carlo method are combined to investigate the dependence of C{sub e} on θ, E and U. Results predict that C{sub e} can exceed A{sub open}, and are applied to optimize the structure and operational parameters of the 20-inch MCP-PMT prototype. C{sub e} of the optimized MCP-PMT is expected to reach 81.2%. Finally, the reduction of the penetration depth of the MCP input electrode layer and the deposition of a high secondary electron yield material on the MCP are proposed to further optimize C{sub e}.

  9. Flow channel shape optimum design for hydroformed metal bipolar plate in PEM fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Linfa; Lai, Xinmin; Liu, Dong' an; Hu, Peng [State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai 200240 (China); Ni, Jun [Department of Mechanical Engineering and Applied Mechanics, University of Michigan, Ann Arbor, MI 48109 (United States)

    2008-03-15

    Bipolar plate is one of the most important and costliest components of polymer electrolyte membrane (PEM) fuel cells. Micro-hydroforming is a promising process to reduce the manufacturing cost of PEM fuel cell bipolar plates made of metal sheets. As for hydroformed bipolar plates, the main defect is the rupture because of the thinning of metal sheet during the forming process. The flow channel section decides whether high quality hydroformed bipolar plates can be successively achieved or not. Meanwhile, it is also the key factor that is related with the reaction efficiency of the fuel cell stacks. In order to obtain the optimum flow channel section design prior the experimental campaign, some key geometric dimensions (channel depth, channel width, rib width and transition radius) of flow channel section, which are related with both reaction efficiency and formability, are extracted and parameterized as the design variables. By design of experiments (DOE) methods and an adoptive simulated annealing (ASA) optimization method, an optimization model of flow channel section design for hydroformed metal bipolar plate is proposed. Optimization results show that the optimum dimension values for channel depth, channel width, rib width and transition radius are 0.5, 1.0, 1. 6 and 0.5 mm, respectively with the highest reaction efficiency (79%) and the acceptable formability (1.0). Consequently, their use would lead to improved fuel cell efficiency for low cost hydroformed metal bipolar plates. (author)

  10. Waveguide module comprising a first plate with a waveguide channel and a second plate with a raised portion in which a sealing layer is forced into the waveguide channel by the raised portion

    Science.gov (United States)

    Strassner, II, Bernd H.; Liedtke, Richard; McDonald, Jacob Jeremiah; Halligan, Matthew

    2018-04-17

    The various technologies presented herein relate to utilizing a sealing layer of malleable material to seal gaps, etc., at a joint between edges of a waveguide channel formed in a first plate and a surface of a clamping plate. A compression pad is included in the surface of the clamping plate and is dimensioned such that the upper surface of the pad is less than the area of the waveguide channel opening on the first plate. The sealing layer is placed between the waveguide plate and the clamping plate, and during assembly of the waveguide module, the compression pad deforms a portion of the sealing layer such that it ingresses into the waveguide channel opening. Deformation of the sealing layer results in the gaps, etc., to be filled, improving the operational integrity of the joint.

  11. Development of a dual MCP framing camera for high energy x-rays

    Energy Technology Data Exchange (ETDEWEB)

    Izumi, N., E-mail: izumi2@llnl.gov; Hall, G. N.; Carpenter, A. C.; Allen, F. V.; Cruz, J. G.; Felker, B.; Hargrove, D.; Holder, J.; Lumbard, A.; Montesanti, R.; Palmer, N. E.; Piston, K.; Stone, G.; Thao, M.; Vern, R.; Zacharias, R.; Landen, O. L.; Tommasini, R.; Bradley, D. K.; Bell, P. M. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); and others

    2014-11-15

    Recently developed diagnostic techniques at LLNL require recording backlit images of extremely dense imploded plasmas using hard x-rays, and demand the detector to be sensitive to photons with energies higher than 50 keV [R. Tommasini et al., Phys. Phys. Plasmas 18, 056309 (2011); G. N. Hall et al., “AXIS: An instrument for imaging Compton radiographs using ARC on the NIF,” Rev. Sci. Instrum. (these proceedings)]. To increase the sensitivity in the high energy region, we propose to use a combination of two MCPs. The first MCP is operated in a low gain regime and works as a thick photocathode, and the second MCP works as a high gain electron multiplier. We tested the concept of this dual MCP configuration and succeeded in obtaining a detective quantum efficiency of 4.5% for 59 keV x-rays, 3 times larger than with a single plate of the thickness typically used in NIF framing cameras.

  12. Development of a new fast shower maximum detector based on microchannel plates photomultipliers (MCP-PMT) as an active element

    Energy Technology Data Exchange (ETDEWEB)

    Ronzhin, A., E-mail: ronzhin@fnal.gov [Fermilab, Batavia, IL 60510 (United States); Los, S.; Ramberg, E. [Fermilab, Batavia, IL 60510 (United States); Spiropulu, M.; Apresyan, A.; Xie, S. [California Institute of Technology, Pasadena, CA (United States); Kim, H. [University of Chicago, Chicago, IL 60637 (United States); Zatserklyaniy, A. [University of California, Santa Cruz, CA (United States)

    2014-09-21

    One possibility to make a fast and radiation resistant shower maximum (SM) detector is to use a secondary emitter as an active element. We present below test beam results, obtained with different types of photodetectors based on microchannel plates (MCPs) as the secondary emitter. We performed the measurements at the Fermilab Test Beam Facility with 120 GeV proton beam and 12 GeV and 32 GeV secondary beams. The goal of the measurement with 120 GeV protons was to determine time resolution for minimum ionizing particles (MIPs). The SM time resolution we obtained for this new type of detector is at the level of 20–30 ps. We estimate that a significant contribution to the detector response originates from secondary emission of the MCP. This work can be considered as the first step in building a new type of calorimeter based on this principle.

  13. PEMFC Performance with Metal Bipolar Plates Depending on the Channel Dimension

    Directory of Open Access Journals (Sweden)

    Kwon Kuikam

    2016-01-01

    Full Text Available Bipolar plates of a proton exchange membrane fuel cell (PEMFC play an important role in removing liquid phase water as a by-product in order to facilitate the reaction between fuel and oxygen. A great amount of effort has been made to improve the performance of a fuel cell such as maximum current density or maximum power, by improving water removability of a bipolar plate. Most of the studies, however, are conducted numerically because of the complexity of analysing gas and liquid and the poor manufacturability of graphite bipolar plates. In this proceeding, we demonstrate that the performance of a PEMFC with metal bipolar plates can be enhanced by reducing the dimension of the channel. Bipolar plates were machined with stainless steel (type 316L to have three different channel size (1000 μm, 500 μm and 300 μm and the performance of each assembled cells were tested. As a result, the maximum power density and the maximum current density increased by 25%.

  14. X-ray radiation channeling in micro-channel plates: Spectroscopy with a synchrotron radiation beam

    International Nuclear Information System (INIS)

    Mazuritskiy, M.I.; Dabagov, S.B.; Marcelli, A.; Dziedzic-Kocurek, K.; Lerer, A.M.

    2015-01-01

    We present here the angular distribution of the radiation propagated inside MultiChannel Plates with micro-channels of ∼3 μm diameter. The spectra collected at the exit of the channels present a complex distribution with contributions that can be assigned to the fluorescence radiation, originated from the excitation of the micro-channel walls. For radiation above the absorption edge, when the monochromatic energy in the region of the Si L-edge hits the micro-channel walls with a grazing angle θ ⩾ 5°, or at the O K-edge when θ ⩾ 2° a fluorescence radiation is detected. Additional information associated to the fine structures of the XANES spectra detected at the exit of MCPs are also presented and discussed

  15. Simulation of the effects of coated material SEY property on output electron energy distribution and gain of microchannel plates

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Lin [Key Laboratory of Ultra-fast Photoelectric Diagnostics Technology, Xi' an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences (CAS), Xi' an 710119 (China); Graduate School of Chinese Academy of Sciences (CAS), Beijing 100049 (China); Xi' an Jiaotong University, Xi' an 710049 (China); Wang, Xingchao [North Night Vision Technology (NNVT) Co., Ltd., Nanjing 210110 (China); Tian, Jinshou, E-mail: tianjs@opt.ac.cn [Key Laboratory of Ultra-fast Photoelectric Diagnostics Technology, Xi' an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences (CAS), Xi' an 710119 (China); Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan 030006 (China); Liu, Chunliang [Xi' an Jiaotong University, Xi' an 710049 (China); Liu, Hulin [Key Laboratory of Ultra-fast Photoelectric Diagnostics Technology, Xi' an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences (CAS), Xi' an 710119 (China); Chen, Ping [Key Laboratory of Ultra-fast Photoelectric Diagnostics Technology, Xi' an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences (CAS), Xi' an 710119 (China); Graduate School of Chinese Academy of Sciences (CAS), Beijing 100049 (China); Wei, Yonglin; Sai, Xiaofeng [Key Laboratory of Ultra-fast Photoelectric Diagnostics Technology, Xi' an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences (CAS), Xi' an 710119 (China); Sun, Jianning; Si, Shuguang [North Night Vision Technology (NNVT) Co., Ltd., Nanjing 210110 (China); Wang, Xing; Lu, Yu [Key Laboratory of Ultra-fast Photoelectric Diagnostics Technology, Xi' an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences (CAS), Xi' an 710119 (China); and others

    2016-12-21

    To obtain a high spatial resolution of a image intensifier based on microchannel plate (MCP), the long tail in the exit energy distribution of the output electrons (EDOE) is undesirable. The existing solution is increasing the penetration depth of the MCP output electrode, which will result in a serious gain reduction. Coating the MCP output electrode with efficient secondary electron yield (SEY) materials is supposed to be an effective approach to suppress the unfavorable tail component in the EDOE without negative effects on the gain. In our work, a three-dimensional MCP single channel model is developed in CST STUDIO SUITE to systematically investigate the dependences of the EDOE and the gain on the SEY property of the coated material, based on the Finite Integral Technique and Monte Carlo method. The results show that besides the high SEY of the coated material, the low incident energy corresponding to the peak SEY is another essential element affecting the electron yield in the final stage of multiplication and suppressing the output energy spread.

  16. Two micron pore size MCP-based image intensifiers

    Science.gov (United States)

    Glesener, John; Estrera, Joseph

    2010-02-01

    Image intensifiers (I2) have many advantages as detectors. They offer single photon sensitivity in an imaging format, they're light in weight and analog I2 systems can operate for hours on a single AA battery. Their light output is such as to exploit the peak in color sensitivity of the human eye. Until recent developments in CMOS sensors, they also were one of the highest resolution sensors available. The closest all solid state solution, the Texas Instruments Impactron chip, comes in a 1 megapixel format. Depending on the level of integration, an Impactron based system can consume 20 to 40 watts in a system configuration. In further investing in I2 technology, L-3 EOS determined that increasing I2 resolution merited a high priority. Increased I2 resolution offers the system user two desirable options: 1) increased detection and identification ranges while maintaining field-of-view (FOV) or 2) increasing FOV while maintaining the original system resolution. One of the areas where an investment in resolution is being made is in the microchannel plate (MCP). Incorporation of a 2 micron MCP into an image tube has the potential of increasing the system resolution of currently fielded systems. Both inverting and non-inverting configurations are being evaluated. Inverting tubes are being characterized in night vision goggle (NVG) and sights. The non-inverting 2 micron tube is being characterized for high resolution I2CMOS camera applications. Preliminary measurements show an increase in the MTF over a standard 5 micron pore size, 6 micron pitch plate. Current results will be presented.

  17. Investigation of power battery thermal management by using mini-channel cold plate

    International Nuclear Information System (INIS)

    Huo, Yutao; Rao, Zhonghao; Liu, Xinjian; Zhao, Jiateng

    2015-01-01

    Highlights: • Micro-channel cold plate was used for battery thermal management. • Maximum temperature of battery decreased with the increase of channel number. • Effect of flow direction on cooling performance is smaller with the increase of flow rate. • Cooling performance increased with the increase of inlet flow rate. • The increasing trend become smaller when the flow rate is high enough. - Abstract: In order to guarantee the safety and extend the cycle life of Li-ion power batteries within electric vehicles, a mini-channel cold plate-based battery thermal management system is designed to cool a rectangular Li-ion battery. A three-dimensional thermal model of the cooling system was established and the effects of number of channels, flow direction, inlet mass flow rate and ambient temperature on temperature rise and distribution of the battery during the discharge process were investigated. The results suggest that the maximum temperature of the battery decreases with increases in the number of channels and inlet mass flow rate. The effect of flow direction on cooling performance was smaller after mass flow rate increased. The cooling performance improved with the increase of inlet mass flow rate but the increasing trend became smaller, and the mass flow rate as 5 × 10 −4 kg s −1 was optimal. The simulation results will be useful for the design of mini-channel cold plate-based battery thermal management system

  18. Capacitively coupled pickup in MCP-based photodetectors using a conductive metallic anode

    Energy Technology Data Exchange (ETDEWEB)

    Angelico, E.; Seiss, T. [Enrico Fermi Institute, University of Chicago, 5640 S Ellis Ave, Chicago, IL 60637 (United States); Adams, B. [Incom, Inc., 294 SouthBridge Rd, Charlton, Massachusetts 01507 (United States); Elagin, A.; Frisch, H.; Spieglan, E. [Enrico Fermi Institute, University of Chicago, 5640 S Ellis Ave, Chicago, IL 60637 (United States)

    2017-02-21

    We have designed and tested a robust 20×20 cm{sup 2} thin metal film internal anode capacitively coupled to an external array of signal pads or micro-strips for use in fast microchannel plate photodetectors. The internal anode, in this case a 10 nm-thick NiCr film deposited on a 96% pure Al{sub 2}O{sub 3} 3 mm-thick ceramic plate and connected to HV ground, provides the return path for the electron cascade charge. The multi-channel pickup array consists of a printed-circuit card or glass plate with metal signal pickups on one side and the signal ground plane on the other. The pickup can be put in close proximity to the bottom outer surface of the sealed photodetector, with no electrical connections through the photodetector hermetic vacuum package other than a single ground connection to the internal anode. Two pickup patterns were tested using a small commercial MCP-PMT as the signal source: 1) parallel 50 Ω 25-cm-long micro-strips with an analog bandwidth of 1.5 GHz, and 2) a 20×20 cm{sup 2} array of 2-dimensional square ‘pads’ with sides of 1.27 cm or 2.54 cm. The rise-time of the fast input pulse is maintained for both pickup patterns. For the pad pattern, we observe 80% of the directly coupled amplitude. For the strip pattern we measure 34% of the directly coupled amplitude on the central strip of a broadened signal. The physical decoupling of the photodetector from the pickup pattern allows easy customization for different applications while maintaining high analog bandwidth.

  19. Instability of a cantilevered flexible plate in viscous channel flow

    Science.gov (United States)

    Balint, T. S.; Lucey, A. D.

    2005-10-01

    The stability of a flexible cantilevered plate in viscous channel flow is studied as a representation of the dynamics of the human upper airway. The focus is on instability mechanisms of the soft palate (flexible plate) that cause airway blockage during sleep. We solve the Navier Stokes equations for flow with Reynolds numbers up to 1500 fully coupled with the dynamics of the plate motion solved using finite-differences. The study is 2-D and based upon linearized plate mechanics. When both upper and lower airways are open, the plate is found to lose its stability through a flutter mechanism and a critical Reynolds number exists. When one airway is closed, the plate principally loses its stability through a divergence mechanism and a critical flow speed exists. However, below the divergence-onset flow speed, flutter can exist for low levels of structural damping in the flexible plate. Our results serve to extend understanding of flow-induced instability of cantilevered flexible plates and will ultimately improve the diagnosis and treatment of upper-airway disorders.

  20. Microchannel plate photodetectors

    International Nuclear Information System (INIS)

    Majka, R.

    1977-01-01

    A review is given the status of development work on photodetectors using microchannel plates (MCP) as the electron gain element. Projections are made and opinions are presented on what might be available in the next few years. Several uses for these devices at ISABELLE are mentioned

  1. Energy and Exergy Analysis of Dual Channel Solar Air Collector with Different Absorber Plates Geometry

    Directory of Open Access Journals (Sweden)

    Najim A. Jassim

    2018-04-01

    Full Text Available Flat-plate collector considers most common types of collectors, for ease of manufacturing and low price compared with other collectors. The main aim of the present work is to increase the efficiency of the collector, which can be achieved by improving the heat transfer and minimize heat loss experimentally. Five types of solar air collectors have been tested, which conventional channel with a smooth absorber plate (model I, dual channel with a smooth absorber plate (model II, dual channel with perforating “V” corrugated absorber plate (model III, dual channel with internal attached wire mesh (model Ⅳ, and dual channel with absorber sheet of transparent honeycomb, (model Ⅴ. The dual channel collector used for increasing heat transfer area and heat removal factor to improve thermal performance. The outdoor test was conducted during the period December (2016 to February (2017 at different mass flow rates 0.0217 kg/s, 0.0271 kg/s and 0.0325 kg/s. The experiments were carried out from 8:30 AM to 3:00 PM for clear days. Experimental results show that the average thermal efficiency was (72.2 % for model (III, (40.2 % for model (I, (51.6 % for model (II, (65.1 % for model (Ⅳ and (59.7 % for model (Ⅴ. At the last part of the study, the exergy analyses were derived for both collectors. The results of this part showed that the conventional channel model (I is having largest irreversibility, and the dual channel collector model (III is having a greatest exergetic efficiency.

  2. Experimental study of bolted connections using light gauge channel sections and packing plates at the joints

    Science.gov (United States)

    Kulkarni, Ravindra B.; Vaghe, Vishal M.

    2014-12-01

    Cold-formed structural members are being used more widely in routine structural design as the world steel industry moves from the production of hot-rolled section and plate to coil and strip, often with galvanized and/or painted coatings. Steel in this form is more easily delivered from the steel mill to the manufacturing plant where it is usually cold-rolled into open and closed section members. In the present experimental study, the use of packing plate at the joints in cold-formed channel sections may increase the load carrying capacity and also reduce the buckling of unconnected cold form channel steel plate at joints. The present study focuses on examining the experimental investigation to use mild steel as a packing plate with cold-formed channel sections by bolted connection at the joints and the connection subjected to axial tension. Series of tests are carried out with increase in the thickness of packing plate and results are observed and analyzed. Total Twelve experimental tests have been carried out on cold-formed channel tension members fastened with single as well as three numbers of bolts at the connection and from the observations the strength of the joint is increased by increasing the various thicknesses of packing plates and also the buckling of unconnected leg of channel specimen is reduced. It is analyzed by plotting the entire load versus elongation path, so that the behavior of the connection is examined.

  3. Analysis of Crystallographic Textures in Aluminum Plates Processed by Equal Channel Angular Extrusion

    DEFF Research Database (Denmark)

    Li, Saiyi; Mishin, Oleg

    2014-01-01

    A modeling and experimental investigation has been conducted to explore the effect of processing route on texture evolution during equal channel angular extrusion (ECAE) of aluminum plate samples. It is found that although the textures in the plates develop along orientation fibers previously ide...... identified for ECAE-processed rods and bars, the main components and strength of these textures vary significantly with processing route, which may lead to considerable differences in the plastic anisotropy of the plates....

  4. Recent developments with microchannel-plate PMTs

    Science.gov (United States)

    Lehmann, A.; Böhm, M.; Britting, A.; Eyrich, W.; Pfaffinger, M.; Uhlig, F.; Belias, A.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Kalicy, G.; Krebs, M.; Lehmann, D.; Nerling, F.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Zühlsdorf, M.; Düren, M.; Etzelmüller, E.; Föhl, K.; Hayrapetyan, A.; Kröck, B.; Merle, O.; Rieke, J.; Schmidt, M.; Wasem, T.; Cowie, E.; Keri, T.; Achenbach, P.; Cardinali, M.; Hoek, M.; Lauth, W.; Schlimme, S.; Sfienti, C.; Thiel, M.

    2017-12-01

    Microchannel-plate (MCP) PMTs are the favored photon sensors for the DIRC detectors of the PANDA experiment at FAIR. Until recently the main drawback of MCP-PMTs were serious aging effects which led to a limited lifetime due to a rapidly decreasing quantum efficiency (QE) of the photo cathode (PC) as the integrated anode charge (IAC) increased. In the latest models of PHOTONIS and Hamamatsu an innovative atomic layer deposition (ALD) technique is applied to overcome these limitations. During the last five years comprehensive aging tests with ALD coated MCP-PMTs were performed and the results were compared to tubes treated with other techniques. The QE in dependence of the IAC was measured as a function of the wavelength and the position across the PC. For the best performing tubes the lifetime improvement in comparison to the older MCP-PMTs is a factor of > 50 based on an IAC of meanwhile > 10 C /cm2 . In addition, the performance results of a new 2-in. ALD coated MCP-PMT prototype from Hamamatsu with a very high position resolution (128×6 anode pixels) is presented and the first conclusions from investigations concerning the PC aging mechanism will be discussed.

  5. Optimizing the longitudinal and transverse electroosmotic pumping in a rectangular channel with horizontal baffle plates

    Science.gov (United States)

    Lai, Anison K. R.; Chang, Chien-Cheng; Wang, Chang-Yi

    2018-04-01

    This paper presents a continued study to our previous work on electroosmotic (EO) flow in a channel with vertical baffle plates by further investigating EO flow through an array of baffle plates arranged in parallel to the channel walls. The flow may be driven either in the direction along or in the direction transverse to the plates, thus distinguishing the longitudinal EO pumping (LEOP) and the transverse EO pumping (TEOP). In both types of EO pumping, it is more interesting to examine the cases when the baffle plates develop a higher zeta potential (denoted by α) than that on the channel walls (β). This semi-analytical study enables us to compare between LEOP and TEOP in the pumping efficiency under similar conditions. The TEOP case is more difficult to solve due to the higher order governing partial differential equations caused by the induced non-uniform pressure gradient distribution. In particular, we examine how the EO pumping rates deviate from those predicted by the Helmholtz-Smoluchowski velocity and illustrate the general trend of optimizing the EO pumping rates with respect to the physical and geometric parameters involved.

  6. Microchannel plates as detectors and amplifiers of x-ray images

    International Nuclear Information System (INIS)

    Wiedwald, J.D.

    1992-08-01

    Two decades of development driven largely by military night vision applications has led to the availability of a wide selection of microchannel plates for use by the scientific community. Microchannel plates (MCPs) are electron multipliers which retain a high degree of spatial resolution making it possible to amplify electron images by factors of 1,000 or more. Plates having 40 mm diameter and intrinsic spatial resolution of 8 μm are readily available. By coating the front surface of a microchannel plate with an x-ray sensitive photocathode material, x-ray images can be detected and amplified. While the detective quantum efficiency is relatively low, the low noise of the MCP (including the ability to construct images by single photon detection) and its high dynamic range make it suitable for some x-ray microscopy applications. The principles of MCP operation and typical performance are discussed. Examples of related applications and commercial capabilities are also presented

  7. Natural convection in an asymmetrically heated vertical channel with an adiabatic auxiliary plate

    International Nuclear Information System (INIS)

    Taieb, Soumaya; Hatem, Laatar Ali; Balti, Jalloul

    2013-01-01

    The effect of an auxiliary plate on natural convection in an asymmetrically heated channel is studied numerically in laminar regime. The computational procedure is made by solving the unsteady two dimensional Navier-Stokes and energy equations. This nonlinear system is integrated by a finite volume approach and then solved in time using the projection method, allowing the decoupling pressure from velocity. More than hundred simulations are performed to determine the best positions of the auxiliary plate that enhance the induced mass flow and the heat transfer rate for modified Rayleigh numbers ranging from Ra m = 10 2 to Ra m = 10 5 . Contour maps are plotted and then used to precise the enhancement rates of the mass flow and the heat transfer for any position of the auxiliary plate in the channel. The numerical results (velocity, pressure and temperature fields) provide detailed information about the evolution of the flow structure according to the geometry considered in this study. In addition, they permit to explain why the mass flow rate and Nusselt number are enhanced for certain positions of the auxiliary plate and are on the contrary deteriorated for others. (authors)

  8. Applications of 'edge-on' illuminated porous plate detectors for diagnostic X-ray imaging

    CERN Document Server

    Shikhaliev, P M

    2002-01-01

    Scanning X-ray imaging systems for non-invasive diagnostics have several advantages over conventional imaging systems using area detectors. They significantly reduce the detected scatter radiation, cover large areas and potentially provide high spatial resolution. Applications of one-dimensional gaseous detectors and 'edge-on' illuminated silicon strip detectors for scanning imaging systems are currently under intensive investigation. The purpose of this work is to investigate 'edge-on' illuminated Porous Plate (PP) detectors for applications in diagnostic X-ray imaging. MicroChannel Plate (MCP), which is a common type of PP, has previously been investigated as a detector in surface-on illumination mode for medical X-ray imaging. However, its detection efficiency was too low for medical imaging applications. In the present study, the PP are used in the 'edge-on' illumination mode. Furthermore, the structural parameters of different PP types are optimized to improve the detection efficiency in the diagnostic X...

  9. Antiproton, positron, and electron imaging with a microchannel plate/phosphor detector

    CERN Document Server

    Andresen, G B; Bowe, P D; Bray, C; Butler, E; Cesar, C L; Chapman, S; Charlton, M; Fajans, J; Fujiwara, M C; Gill, D R; Hangst, J S; Hardy, W N; Hayano, R S; Hayden, M E; Humphries, A J; Hydomako, R; Jørgensen, L V; Kerrigan, S J; Kurchaninov, L; Lambo, R; Madsen, N; Nolan, P; Olchanski, K; Olin, A; Povilus, A; Pusa, P; Sarid, E; Seif El Nasr, S; Silveira, D M; Storey, J W; Thompson, R I; van der Werf, D P; Yamazaki, Y

    2009-01-01

    A microchannel plate (MCP)/phosphor screen assembly has been used to destructively measure the radial profile of cold, confined antiprotons, electrons, and positrons in the ALPHA experiment, with the goal of using these trapped particles for antihydrogen creation and confinement. The response of the MCP to low energy (10-200 eV, <1 eV spread) antiproton extractions is compared to that of electrons and positrons.

  10. Synthesis of Rh/Macro-Porous Alumina Over Micro-Channel Plate and Its Catalytic Activity Tests for Diesel Reforming.

    Science.gov (United States)

    Seong, Yeon Baek; Kim, Yong Sul; Park, No-Kuk; Lee, Tae Jin

    2015-11-01

    Macro-porous Al2O3 as the catalytic support material was synthesized using colloidal polystyrene spheres over a micro-channel plate. The colloidal polystyrene spheres were used as a template for the production of an ordered macro porous material using an alumina nitrate solution as the precursor for Al2O3. The close-packed colloidal crystal array template method was applied to the formulation of ordered macro-porous Al2O3 used as a catalytic support material over a micro-channel plate. The solvent in the mixture solution, which also contained the colloidal polystyrene solution, aluminum nitrate solution and the precursor of the catalytic active materials (Rh), was evaporated in a vacuum oven at 50 degrees C. The ordered polystyrene spheres and aluminum salt of the solid state were deposited over a micro channel plate, and macro-porous Al2O3 was formed after calcination at 600 degrees C to remove the polystyrene spheres. The catalytic activity of the Rh/macro-porous alumina supported over the micro-channel plate was tested for diesel reforming.

  11. Diapir versus along-channel ascent of crustal material during plate convergence: constrained by the thermal structure of subduction zones

    Science.gov (United States)

    Liu, M. Q.; Li, Z. H.

    2017-12-01

    Crustal rocks can be subducted to mantle depths, interact with the mantle wedge, and then exhume to the crustal depth again, which is generally considered as the mechanism for the formation of ultrahigh-pressure metamorphic rocks in nature. The crustal rocks undergo dehydration and melting at subarc depths, giving rise to fluids that metasomatize and weaken the overlying mantle wedge. There are generally two ways for the material ascent from subarc depths: one is along subduction channel; the other is through the mantle wedge by diapir. In order to study the conditions and dynamics of these contrasting material ascent modes, systematic petrological-thermo-mechanical numerical models are constructed with variable thicknesses of the overriding and subducting continental plates, ages of the subducting oceanic plate, as well as the plate convergence rates. The model results suggest that the thermal structures of subduction zones control the thermal condition and fluid/melt activity at the slab-mantle interface in subcontinental subduction channels, which further strongly affect the material transportation and ascent mode. Thick overriding continental plate and low-angle subduction style induced by young subducting oceanic plate both contribute to the formation of relatively cold subduction channels with strong overriding mantle wedge, where the along-channel exhumation occurs exclusively to result in the exhumation of HP-UHP metamorphic rocks. In contrast, thin overriding lithosphere and steep subduction style induced by old subducting oceanic plate are the favorable conditions for hot subduction channels, which lead to significant hydration and metasomatism, melting and weakening of the overriding mantle wedge and thus cause the ascent of mantle wedge-derived melts by diapir through the mantle wedge. This may corresponds to the origination of continental arc volcanism from mafic to ultramafic metasomatites in the bottom of the mantle wedge. In addition, the plate

  12. Lifetime of MCP-PMTs and other performance features

    Science.gov (United States)

    Lehmann, A.; Böhm, M.; Eyrich, W.; Miehling, D.; Pfaffinger, M.; Stelter, S.; Uhlig, F.; Ali, A.; Belias, A.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Kalicy, G.; Krebs, M.; Lehmann, D.; Nerling, F.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Düren, M.; Etzelmüller, E.; Föhl, K.; Hayrapetyan, A.; Kreutzfeld, K.; Merle, O.; Rieke, J.; Schmidt, M.; Wasem, T.; Achenbach, P.; Cardinali, M.; Hoek, M.; Lauth, W.; Schlimme, S.; Sfienti, C.; Thiel, M.

    2018-02-01

    The bar PANDA experiment at FAIR will use DIRC detectors for the separation of hadrons. The compactness of the bar PANDA detector requires the image planes of these detectors to be placed inside the magnetic field of the solenoid. Due to this and other boundary conditions MCP-PMTs were identified as the only suitable photon sensors. Until recently the major obstacle for an application of MCP-PMTs in high rate experiments like bar PANDA were serious aging problems which led to damage at the photo-cathode and a fast declining quantum efficiency as the integrated anode charge (IAC) increased. With new countermeasures against the aging, in particular due to the application of an atomic layer deposition (ALD) technique to coat the MCP pores, the lifetime of MCP-PMTs has meanwhile increased by a factor >50 which is fully sufficient for bar PANDA. The recent results of our long-term lifetime measurements are discussed. New 2-inch MCP-PMT prototypes from Hamamatsu show an encouraging behavior. However, the currently best performing MCP-PMT is a 2-inch PHOTONIS tube with two ALD-layers which reaches an IAC of >16 C/cm2 without any visible sign of aging. In the second part of these proceedings a new data acquisition system of the PADIWA/TRB type is presented which allows a quasi-parallel measurement of many MCP-PMT performance parameters. Especially unwanted effects like dark-count rate, crosstalk, ion after-pulsing, and recoil electrons can be studied in more detail than ever before. Exemplary results for these parameters are shown. The discussed DAQ system will be used for the comprehensive data quality checks of the MCP-PMTs being built into the DIRCs.

  13. Systemic MCP1/CCR2 blockade and leukocyte specific MCP1/CCR2 inhibition affect aortic aneurysm formation differently

    NARCIS (Netherlands)

    de Waard, Vivian; Bot, Ilze; de Jager, Saskia C. A.; Talib, Sara; Egashira, Kensuke; de Vries, Margreet R.; Quax, Paul H. A.; Biessen, Erik A. L.; van Berkel, Theo J. C.

    2010-01-01

    Objective: CCR2, the receptor for monocyte chemoattractant protein 1 (MCP1), is involved in atherosclerosis and abdominal aortic aneurysms (AAAs). Here, we explored the potential beneficial blockade of the MCP1/CCR2 pathway. Methods: We applied an AAA model in aging apolipoprotein E deficient mice

  14. Improved lifetime of microchannel-plate PMTs

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, A., E-mail: lehmann@physik.uni-erlangen.de [Physikalisches Institut IV, Friedrich Alexander-University of Erlangen-Nuremberg, Erlangen (Germany); Britting, A.; Eyrich, W.; Uhlig, F. [Physikalisches Institut IV, Friedrich Alexander-University of Erlangen-Nuremberg, Erlangen (Germany); Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Höhler, R.; Kalicy, G.; Kumawat, H.; Lehmann, D.; Lewandowski, B.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Zühlsdorf, M. [GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt (Germany); and others

    2014-12-01

    The charged particle identification at the PANDA experiment will be mainly performed with DIRC detectors. Because of their advantageous properties the preferred photon sensors are MCP-PMTs. However, until recently these devices showed serious aging problems which resulted in a diminishing quantum efficiency (QE) of the photo cathode. By applying innovative countermeasures against the aging causes, the manufacturers recently succeeded in drastically improving the lifetime of MCP-PMTs. Especially the application of an ALD coating technique to seal the material of the micro-channels proves very powerful and results in a lifetime of ≈6C/cm{sup 2} integrated anode charge without a substantial QE degradation for the latest PHOTONIS XP85112. This paper will present a comparative measurement of the lifetime of several older and recent MCP-PMTs demonstrating this progress.

  15. Development of MCP transient operation strategy for the SMART-P

    International Nuclear Information System (INIS)

    Yoo, S. E.; Choi, B. S.; Kang, H. O.; Yoon, J. H.; Ji, S. K.

    2003-01-01

    SMART-P MCP(Main Coolant Pump) transient operation strategies are developed. A Modular Modeling System (MMS) computer code is used for the evaluation of the developed operation strategies. In the SMART-P, normal operating modes are classified into MCP high speed(3600 rpm) mode and MCP low speed mode. Also, natural circulation mode is defined as a performance test case. MCP operation transients occur when changing modes from one to another, and system parameters(core power, system pressure, temperature) are having transients. These transients affect on system performance and, in some cases, limit system operation. In this study, MCP operation strategies are developed and obtained acceptable results

  16. MCP-1 expressed by osteoclasts stimulates osteoclastogenesis in an autocrine/paracrine manner

    International Nuclear Information System (INIS)

    Miyamoto, Kana; Ninomiya, Ken; Sonoda, Koh-Hei; Miyauchi, Yoshiteru; Hoshi, Hiroko; Iwasaki, Ryotaro; Miyamoto, Hiroya

    2009-01-01

    Monocyte chemoattractant protein-1 (MCP-1) is a chemokine that plays a critical role in the recruitment and activation of leukocytes. Here, we describe that multinuclear osteoclast formation was significantly inhibited in cells derived from MCP-1-deficient mice. MCP-1 has been implicated in the regulation of osteoclast cell-cell fusion; however defects of multinuclear osteoclast formation in the cells from mice deficient in DC-STAMP, a seven transmembrane receptor essential for osteoclast cell-cell fusion, was not rescued by recombinant MCP-1. The lack of MCP-1 in osteoclasts resulted in a down-regulation of DC-STAMP, NFATc1, and cathepsin K, all of which were highly expressed in normal osteoclasts, suggesting that osteoclast differentiation was inhibited in MCP-1-deficient cells. MCP-1 alone did not induce osteoclastogenesis, however, the inhibition of osteoclastogenesis in MCP-1-deficient cells was restored by addition of recombinant MCP-1, indicating that osteoclastogenesis was regulated in an autocrine/paracrine manner by MCP-1 under the stimulation of RANKL in osteoclasts.

  17. Associations between Deceased-Donor Urine MCP-1 and Kidney Transplant Outcomes.

    Science.gov (United States)

    Mansour, S G; Puthumana, J; Reese, P P; Hall, I E; Doshi, M D; Weng, F L; Schröppel, B; Thiessen-Philbrook, H; Bimali, M; Parikh, C R

    2017-07-01

    Existing methods to predict recipient allograft function during deceased-donor kidney procurement are imprecise. Understanding the potential renal reparative role for monocyte chemoattractant protein-1 (MCP-1), a cytokine involved in macrophage recruitment after injury, might help predict allograft outcomes. We conducted a sub-study of the multicenter prospective Deceased Donor Study cohort, which evaluated deceased kidney donors from five organ procurement organizations from May 2010 to December 2013. We measured urine MCP-1 (uMCP-1) concentrations from donor samples collected at nephrectomy to determine associations with donor acute kidney injury (AKI), recipient delayed graft function (DGF), 6-month estimated GFR (eGFR), and graft failure. We also assessed perfusate MCP-1 concentrations from pumped kidneys for associations with DGF and 6-month eGFR. AKI occurred in 111 (9%) donors. Median (interquartile range) uMCP-1 concentration was higher in donors with AKI compared to donors without AKI (1.35 [0.41-3.93] ng/ml vs. 0.32 [0.11-0.80] ng/ml, p<0.001). DGF occurred in 756 (31%) recipients, but uMCP-1 was not independently associated with DGF. Higher donor uMCP-1 concentrations were independently associated with higher 6-month eGFR in those without DGF [0.77 (0.10, 1.45) ml/min/1.73m 2 per doubling of uMCP1]. However, there were no independent associations between uMCP-1 and graft failure over a median follow-up of about 2 years. Lastly, perfusate MCP-1 concentrations significantly increased during pump perfusion but were not associated with DGF or 6-month eGFR. Donor uMCP-1 concentrations were modestly associated with higher recipient 6-month eGFR in those without DGF. However, the results suggest that donor uMCP-1 has minimal clinical utility given no associations with graft failure.

  18. Proper orthogonal decomposition applied to laminar thermal convection in a vertical two plate channel

    International Nuclear Information System (INIS)

    Alvarez-Herrera, C; Murillo-Ramírez, J G; Pérez-Reyes, I; Moreno-Hernández, D

    2015-01-01

    This work reports the thermal convection with imposed shear flow in a thin two-plate channel. Flow structures are investigated under heating asymmetric conditions and different laminar flow conditions. The dynamics of heat flow and the energy distribution were determined by visualization with the Schlieren technique and application of the proper orthogonal decomposition (POD) method. The obtained results from the POD mode analysis revealed that for some flow conditions the heat transfer is related to the energy of the POD modes and their characteristic numbers. It was possible to detect periodic motion in the two-plate channel flow from the POD mode analysis. It was also found that when the energy is distributed among many POD modes, the fluid flow is disorganized and unsteady. (paper)

  19. Measurements of recent microchannel-plate photomultipliers with significantly increased lifetime

    Energy Technology Data Exchange (ETDEWEB)

    Uhlig, Fred; Eyrich, Wolfgang; Lehmann, Albert; Britting, Alexander [Universitaet Erlangen, Physikal. Institut IV (Germany); Collaboration: PANDA-Collaboration

    2015-07-01

    Microchannel-plate photomultipliers (MCP-PMTs) are the favored sensors for the DIRC detectors (Detection of Internally Reflected Cherenkov Light) of the PANDA experiment. They are usable in high magnetic fields of up to 2T and reach a time resolution of better than 50 ps (σ). The anticipated average luminosity of 2.10{sup 32} cm{sup -2} s{sup -1} in the detector requires a rate capability high enough to withstand a detected photon rate of about 200 kHz cm{sup -2} at the MCP-PMT surfaces. The major drawback until recently was the limited lifetime of MCP-PMTs, which appears to be solved for the latest generation of MCP-PMT prototype devices. The aging parameter is the quantum efficiency as a function of the integrated anode charge, which will be in the region of 5 C/cm{sup 2} for the Barrel- and the Disc-DIRC. We simultaneously measured the aging of several MCP-PMTs, which were treated with different methods to enhance the lifetime. Results of these measurements are presented.

  20. Combined effects of 1-methyl cyclopropene (1-MCP) and modified ...

    African Journals Online (AJOL)

    1-MCP-treated fruits delayed two different harvest maturity, persimmon fruits flesh firmness, and combination of 1-MCP with MAPA and MAPB reduced the ethylene production rate during storage. Treatment of 1-MCP improved storability of persimmon fruits more effectively than MAP storage. However, the results indicated ...

  1. Inexpensive read-out for coincident electron spectroscopy with a transmission electron microscope at nanometer scale using micro channel plates and multistrip anodes

    International Nuclear Information System (INIS)

    Hollander, R.W.; Bom, V.R.; Van Eijk, C.W.E.; Faber, J.S.; Hoevers, H.; Kruit, P.

    1994-01-01

    The elemental composition of a sample at nanometer scale is determined by measurement of the characteristic energy of Auger electrons, emitted in coincidence with incoming primary electrons from a microbeam in a scanning transmission electron microscope (STEM). Single electrons are detected with position sensitive detectors, consisting of MicroChannel Plates (MCP) and MultiStrip Anodes (MSA), one for the energy of the Auger electrons (Auger-detector) and one for the energy loss of primary electrons (EELS-detector). The MSAs are sensed with LeCroy 2735DC preamplifiers. The fast readout is based on LeCroy's PCOS III system. On the detection of a coincidence (Event) energy data of Auger and EELS are combined with timing data to an Event word. Event words are stored in list mode in a VME memory module. Blocks of Event words are scanned by transputers in VME and two-dimensional energy histograms are filled using the timing information to obtain a maximal true/accidental ratio. The resulting histograms are stored on disk of a PC-386, which also controls data taking. The system is designed to handle 10 5 Events per second, 90% of which are accidental. In the histograms the ''true'' to ''accidental'' ratio will be 5. The dead time is 15%. ((orig.))

  2. The size and spatial distribution of microchannel plate output electron clouds

    International Nuclear Information System (INIS)

    Lapington, J.S.; Edgar, M.L.

    1989-01-01

    An experimental technique for measuring the spatial distribution of the output charge cloud from a microchannel plate (MCP), using a planar, charge-division-type anode is discussed. The anode simultaneously measures, for each charge cloud, both the position of the charge centroid and the fractional charge falling to one side of the split in the pattern. The measurements from several thousand events have been combined to calculate the average spatial distribution of the electron cloud and the dominant factors influencing the charge cloud distribution have been found to be the MCP gain and the MCP-anode accelerating field and geometry. Experimental research on the two dominant factors with respect to ranges of distribution is presented. 10 refs

  3. CCL2/MCP-1 modulation of microglial activation and proliferation

    Directory of Open Access Journals (Sweden)

    Garcia-Bueno Borja

    2011-07-01

    Full Text Available Abstract Background Monocyte chemoattractant protein (CCL2/MCP-1 is a chemokine that attracts cells involved in the immune/inflammatory response. As microglia are one of the main cell types sustaining inflammation in brain, we proposed here to analyze the direct effects of MCP-1 on cultured primary microglia. Methods Primary microglia and neuronal cultures were obtained from neonatal and embryonic Wistar rats, respectively. Microglia were incubated with different concentrations of recombinant MCP-1 and LPS. Cell proliferation was quantified by measuring incorporation of bromodeoxyuridine (BrdU. Nitrite accumulation was measured using the Griess assay. The expression and synthesis of different proteins was measured by RT-PCR and ELISA. Cell death was quantified by measuring release of LDH into the culture medium. Results MCP-1 treatment (50 ng/ml, 24 h did not induce morphological changes in microglial cultures. Protein and mRNA levels of different cytokines were measured, showing that MCP-1 was not able to induce proinflammatory cytokines (IL-1β, IL6, MIP-1α, either by itself or in combination with LPS. A similar lack of effect was observed when measuring inducible nitric oxide synthase (NOS2 expression or accumulation of nitrites in the culture media as a different indicator of microglial activation. MCP-1 was also unable to alter the expression of different trophic factors that were reduced by LPS treatment. In order to explore the possible release of other products by microglia and their potential neurotoxicity, neurons were co-cultured with microglia: no death of neurons could be detected when treated with MCP-1. However, the presence of MCP-1 induced proliferation of microglia, an effect opposite to that observed with LPS. Conclusion These data indicate that, while causing migration and proliferation of microglia, MCP-1 does not appear to directly activate an inflammatory response in this cell type, and therefore, other factors may be

  4. The parameterization of microchannel-plate-based detection systems

    Science.gov (United States)

    Gershman, Daniel J.; Gliese, Ulrik; Dorelli, John C.; Avanov, Levon A.; Barrie, Alexander C.; Chornay, Dennis J.; MacDonald, Elizabeth A.; Holland, Matthew P.; Giles, Barbara L.; Pollock, Craig J.

    2016-10-01

    The most common instrument for low-energy plasmas consists of a top-hat electrostatic analyzer (ESA) geometry coupled with a microchannel-plate-based (MCP-based) detection system. While the electrostatic optics for such sensors are readily simulated and parameterized during the laboratory calibration process, the detection system is often less well characterized. Here we develop a comprehensive mathematical description of particle detection systems. As a function of instrument azimuthal angle, we parameterize (1) particle scattering within the ESA and at the surface of the MCP, (2) the probability distribution of MCP gain for an incident particle, (3) electron charge cloud spreading between the MCP and anode board, and (4) capacitive coupling between adjacent discrete anodes. Using the Dual Electron Spectrometers on the Fast Plasma Investigation on NASA's Magnetospheric Multiscale mission as an example, we demonstrate a method for extracting these fundamental detection system parameters from laboratory calibration. We further show that parameters that will evolve in flight, namely, MCP gain, can be determined through application of this model to specifically tailored in-flight calibration activities. This methodology provides a robust characterization of sensor suite performance throughout mission lifetime. The model developed in this work is not only applicable to existing sensors but also can be used as an analytical design tool for future particle instrumentation.

  5. Optimization design of a 20-in. elliptical MCP-PMT

    International Nuclear Information System (INIS)

    Chen, Ping; Tian, Jinshou; Wei, Yonglin; Liu, Hulin; Sai, Xiaofeng; He, Jianping; Chen, Lin; Wang, Xing; Lu, Yu

    2017-01-01

    This paper describes the simulation work for optimizing the newly developed 20-in. elliptical MCP-PMT by enlarging the outside diameters of the two focusing electrodes and the open area of the glass bulb. Effects of biasing voltages applied to the two focusing electrodes and the MCP input facet are studied. With the new design of the 20 in. MCP-PMT, the transit time spread of the prototype can be less than 3 ns and the collection efficiency is as much as the present prototype.

  6. How to prevent ripening blockage in 1-MCP-treated 'Conference' pears.

    Science.gov (United States)

    Chiriboga, Maria-Angeles; Schotsmans, Wendy C; Larrigaudière, Christian; Dupille, Eve; Recasens, Inmaculada

    2011-08-15

    Some European pear varieties treated with 1-methylcyclopropene (1-MCP) often remain 'evergreen', meaning that their ripening process is blocked and does not resume after removal from cold storage. In this work this was confirmed also to be the case in 'Conference' pears. To reverse the blockage of ripening 1-MCP treatments combined with external exogenous ethylene were tested. 1-MCP treatment of 'Conference' pears is very effective in delaying ripening and, more specifically, softening. The same 1-MCP concentration in different experimental years caused a different response. The higher dose of 1-MCP (600 nL L⁻¹) always resulted in irreversible blockage of ripening, whereas the behaviour of fruit receiving a lower dose (300 nL L⁻¹) depended on the year, and this did not depend on maturity at harvest or on storage conditions. Simultaneous exposure to 1-MCP and exogenous ethylene significantly affected fruit ripening, allowing significant softening to occur but at a lower rate compared with control fruit. The application of exogenous ethylene and 1-MCP simultaneously after harvest permitted restoration of the ripening process after storage in 'Conference' pears, extending the possibility of marketing and consumption. Copyright © 2011 Society of Chemical Industry.

  7. Electron optics design of an 8-in. spherical MCP-PMT

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Ping, E-mail: chenping@opt.cn [Key Laboratory of Ultra-fast photoelectric Diagnostics Technology, Xi’an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences, Xi’an 710119 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan 030006, Shanxi (China); Tian, Jinshou [Key Laboratory of Ultra-fast photoelectric Diagnostics Technology, Xi’an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences, Xi’an 710119 (China); Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan 030006, Shanxi (China); Qian, Sen; Zhao, Tianchi [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Liu, Hulin; Wei, Yonglin; Sai, Xiaofeng; He, Jianping; Wang, Xing; Lu, Yu [Key Laboratory of Ultra-fast photoelectric Diagnostics Technology, Xi’an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences, Xi’an 710119 (China); Chen, Lin; Guo, Lehui; Pei, Chengquan; Hui, Dandan [Key Laboratory of Ultra-fast photoelectric Diagnostics Technology, Xi’an Institute of Optics and Precision Mechanics (XIOPM), Chinese Academy of Sciences, Xi’an 710119 (China); University of Chinese Academy of Sciences, Beijing 100049 (China)

    2017-03-11

    This paper discusses the electron optical system of an 8-in. spherical MCP-PMT. The MCP assembly, the supporting pole and the supply voltages are carefully designed to optimize the photoelectron collection efficiency and the transit time spread. Coating the MCP nickel-chromium electrode with an additional high secondary emission material is employed to make a breakthrough on the collection efficiency. With the simulation software CST, the Finite Integration method and the Monte Carlo method are combined to evaluate the collection efficiency, the time properties and the Earth's magnetic field effects. Simulation results show that the photocathode active solid angle is over 3.5 πsr, the average collection efficiency can exceed 95% with the coated MCP and the mean transit time spread is 2.2 ns for a typical electric potential of 500 V applied between the photocathode and the MCP input facet. The prototype and the measured single photoelectron spectrum are also presented.

  8. MCP1 haplotypes associated with protection from pulmonary tuberculosis

    Directory of Open Access Journals (Sweden)

    Owusu-Dabo Ellis

    2011-04-01

    Full Text Available Abstract Background The monocyte chemoattractant protein 1 (MCP-1 is involved in the recruitment of lymphocytes and monocytes and their migration to sites of injury and cellular immune reactions. In a Ghanaian tuberculosis (TB case-control study group, associations of the MCP1 -362C and the MCP1 -2581G alleles with resistance to TB were recently described. The latter association was in contrast to genetic effects previously described in study groups originating from Mexico, Korea, Peru and Zambia. This inconsistency prompted us to further investigate the MCP1 gene in order to determine causal variants or haplotypes genetically and functionally. Results A 14 base-pair deletion in the first MCP1 intron, int1del554-567, was strongly associated with protection against pulmonary TB (OR = 0.84, CI 0.77-0.92, Pcorrected = 0.00098. Compared to the wildtype combination, a haplotype comprising the -2581G and -362C promoter variants and the intronic deletion conferred an even stronger protection than did the -362C variant alone (OR = 0.78, CI 0.69-0.87, Pnominal = 0.00002; adjusted Pglobal = 0.0028. In a luciferase reporter gene assay, a significant reduction of luciferase gene expression was observed in the two constructs carrying the MCP1 mutations -2581 A or G plus the combination -362C and int1del554-567 compared to the wildtype haplotype (P = 0.02 and P = 0.006. The associated variants, in particular the haplotypes composed of these latter variants, result in decreased MCP-1 expression and a decreased risk of pulmonary TB. Conclusions In addition to the results of the previous study of the Ghanaian TB case-control sample, we have now identified the haplotype combination -2581G/-362C/int1del554-567 that mediates considerably stronger protection than does the MCP1 -362C allele alone (OR = 0.78, CI 0.69-0.87 vs OR = 0.83, CI 0.76-0.91. Our findings in both the genetic analysis and the reporter gene study further indicate a largely negligible role of the

  9. Influência do 1-MCP na conservação pós-colheita de rosas cv. Vega Influence of 1-MCP on postharvest conservation of roses cv. Vega

    Directory of Open Access Journals (Sweden)

    Júlia De Pietro

    2010-10-01

    Full Text Available Objetivou-se, neste trabalho, estudar aspectos da fisiologia pós-colheita de rosas cortadas cv. Vega, tratadas com diferentes concentrações de 1-metilcicloropropeno (1-MCP. O experimento foi conduzido em delineamento inteiramente casualizado, em esquema fatorial composto por dois fatores: quatro tratamentos pós-colheita e quatro datas de avaliação (0; 4; 8; 12 dias. As flores foram submetidas aos seguintes tratamentos: 1 Água destilada (controle; 2 1-MCP (100 ppb; 3 1-MCP (250 ppb; 4 1-MCP (500 ppb. Foram realizadas as seguintes avaliações: massa fresca, cor, turgescência, curvatura, taxa respiratória, conteúdo relativo de água, conteúdo de carboidratos solúveis, de redutores e de antocianina. Ao contrário do tratamento controle, todas as concentrações de 1-MCP foram eficientes para retardar a senescência das flores, porém, a concentração de 1-MCP a 500 ppb destacou-se pela melhor manutenção da qualidade, além de prolongar a vida decorativa das hastes até 19 dias.The objective of this work was to study aspects of postharvest physiology of cut roses cv. Vega, treated with different concentrations of 1-metilcloropropene (1-MCP. The experiment was conducted in a complete randomized design composed of two factors: four postharvest treatments and four dates of evaluation (0; 4; 8; 12 days. The following treatments were used: 1 distilled water; 2 1-metilciclopropeno (1-MCP 100 ppb; 3 1-MCP 250 ppb; 4 1-MCP 500 ppb. The following evaluations were made: fresh weight, color, turgor, curvature, respiration rate, relative water content, content of soluble carbohydrates, reducing and anthocyanin. Unlike treatment with distilled water, all concentrations of 1-MCP were effective in delaying the senescence of flowers; however, the concentration of 1-MCP at 500 ppb was highlighted by better maintenance of quality and extended decorate life stem up to 19 days.

  10. Influences of bipolar plate channel blockages on PEM fuel cell performances

    International Nuclear Information System (INIS)

    Heidary, Hadi; Kermani, Mohammad J.; Dabir, Bahram

    2016-01-01

    Highlights: • Effect of partial- or full-blockage of PEMFC flow channels is numerically studied. • The anode blockage does not show any positive effects on cell performance. • Full blockages, despite higher pressure drop, better enhance net electrical power. • Additions of blocks more than five do not improve the cell performance. • Full blockage of cathode channels with five blocks enhances the net power by 30%. - Abstract: In this paper, the effect of partial- or full-block placement along the flow channels of PEM fuel cells is numerically studied. Blockage in the channel of flow-field diverts the flow into the gas diffusion layer (GDL) and enhances the mass transport from the channel core part to the catalyst layer, which in turn improves the cell performance. By partial blockage, only a part of the channel flow is shut off. While in full blockage, in which the flow channel cross sections are fully blocked, the only avenue left for the continuation of the gas is to travel over the blocks via the porous zone (GDL). In this study, a 3D numerical model consisting of a 9-layer PEM fuel cell is performed. A wide spectrum of numerical studies is performed to study the influences of the number of blocks, blocks height, and anode/cathode-side flow channel blockage. The results show that the case of full blockage enhances the net electrical power more than that of the partial blockage, in spite of higher pressure drop. Performed studies show that full blockage of the cathode-side flow channels with five blocks along the 5 cm channel enhances the net power by 30%. The present work provides helpful guidelines to bipolar plate manufacturers.

  11. Conjugated heat transfer in laminar flow between parallel-plates channel

    International Nuclear Information System (INIS)

    Guedes, R.O.C.; Cotta, R.M.; Brum, N.C.L.

    1989-01-01

    An analysis is made of conjugated convective-conductive heat transfer in laminar flow of a newtonian fluid between parallel-plates channel, taking into account the longitudinal conduction along the duct walls only, by neglecting the transversal temperature gradients in the solid. This extended Graetz-type problem is then analytically handled through the generalized integral transform technique, providing accurate numerical results for quantities of practical interest sucyh as bulk and wall temperatures, and Nusselt numbers. The effects of a conjugation parameter and Biot number on heat transfer behavior are then investigated. (author)

  12. A new method to measure and increase the detection efficiency of a microchannel plate for 100 keV electrons

    International Nuclear Information System (INIS)

    Tornow, R.P.

    1990-01-01

    A new method is described which permits measurement of efficiency of a microchannel plate (MCP) simply by tracing the output current pulse in the saturated mode. The dependence of the detection efficiency on the gain of the input stages of a detector is calculated and the result is applied to a MCP. Furthermore, an enhancement of the detection efficiency of a MCP is presented for 100 keV electrons up to more than 90% by means of the field-enhanced secondary electron emission. (author)

  13. Development of microchannel plates in advanced wind-tunnel instrumentation

    Science.gov (United States)

    Feller, W. Bruce

    1990-01-01

    Microchannel plate (MCP) electron multiplier dynamic range has been increased 3 to 4 orders of magnitude at ambient temperatures, through enhanced input count rate capability and reduced background or 'dark' noise. The previous upper limit of roughly 10(exp 7) - 10(exp 8) cm(exp -2)s(exp -1) at ambient has been extended to levels approach 10(exp 10) cm(exp -2)s(exp -1) under continuous dc operation. The lower limit, previously set by an irreducible background component (approximately 0.6 cm(exp -2)s(exp -1)), has been lowered to the cosmic ray limit of .01 cm(exp -2)s(exp -1). The high end improvement was achieved by conductively cooling a very low resistance MCP by bonding it to a heat sink, while maintaining pulse-counting operation with multianode readouts. The low-end improvement was achieved by removing all radioisotopes from the MCP matrix glass. The detectors will benefit optical and mass spectrometry, flow visualization, plasma diagnostics, magnetometry, and other high signal flux applications. Very low MCP background noise will benefit X-ray and UV astronomy, medical imaging, trace isotope mass spectrometry, and other applications where the signal flux is often extremely low.

  14. Innovative microchannel plate with reformulation of composition and modification of microstructure

    Science.gov (United States)

    Pan, Jingsheng; Lv, Jingwen; Kesaev, S. A.; Liu, Shulin; Liu, Zhanying; Li, Junguo; Chong, Xiaoqin; Shu, Detan

    2009-07-01

    The signal-to-noise ratio (SNR) and mean time to failure (MTTF) are two important attributes to describe the performance and operation life of an image intensifier. The presents of the ion barrier film (IBF) in Gen. III image intensifier, which used to suppress MCP's ion feedback, while dramatically improve the MTTF but significantly reduce the SNR, so more completely diminishing the ion poisoning source within the channels of MCP are crucial for improved Gen. III; image intensifier to thinned thickness IBF and achieving this two conflicting attributes promotion simultaneously. This research was originally initiated to develop a MCP with glass composition redesigned specially for GaAs photocathode image intensifier, proved which can be imposed an exceedingly intensive electron bombard degassing but without suffering a fatal gain degrade, and had achieved significantly improved SNR of Gen. III image intensifier but with a short distance to meet the lifetime success, so that our research work step forward to intent upon the restriction of ion poisoning source formation within the MCP substrate, we reformulated the MCP glass composition, and modified the microstructure of this MCP glass substrate though a glass-crystal phase transition during the MCP fabricate heating process, we present an innovative MCP based on a glass-ceramic substrate, with reformulated composition and close-linked network microstructure mix with many of nanometer size crystal grains, provide this MCP with sustainable high gain, lower ion feedback and less outgasing performance, this glass-ceramic MCPs are assembled to Gen. III image intensifiers which results showing promoting both the MTTF and SNR of Gen. III image intensifier.

  15. Study on MCP-1 related to inflammation induced by biomaterials

    International Nuclear Information System (INIS)

    Ding Tingting; Sun Jiao; Zhang Ping

    2009-01-01

    The study of inflammation is important for understanding the reaction between biomaterials and the human body, in particular, the interaction between biomaterials and immune system. In the current study, rat macrophages were induced by multiple biomaterials with different biocompatibilities, including polyvinyl chloride (PVC) containing 8% of organic tin, a positive control material with cellular toxicity. Human umbilical vein endothelial cells (ECV-304), cultured with PRMI-1640, were detached from cells cultured with the supernatant of macrophages containing TNF-α and IL-1β because of stimulation by biomaterials. The cells were then treated with different biomaterials. Then both TNF-α and IL-1β in macrophages were detected by ELISA. Levels of monocyte chemoattractant protein-1 (MCP-1) were measured by RT-PCR. The results suggested that the expression of TNF-α and IL-1β was elevated by polytetrafluoroethylene (PTFE), polylactic-co-glycolic acid (PLGA) and American NPG alloy (p < 0.001). The level of MCP-1 cultured in supernatant of macrophages was higher than in PRMI-1640 with the same biomaterials. And the exposure to PTFE, PLGA and NPG resulted in the high expression of MCP-1 (p < 0.001) following cytokine stimulation. MCP-1 was also significantly expressed in β-tricalcium phosphate (β-TCP) and calcium phosphate cement samples (CPC) (p < 0.01). Thus, TNF-α, IL-1β and MCP-1 had played an important role in the immune reaction induced by biomaterials and there was a close relationship between the expression of cytokines and biomcompatibility of biomaterials. Furthermore, these data suggested that MCP-1 was regulated by TNF-α and IL-1β, and activated by both cytokines and biomaterials. The data further suggested that the expression of MCP-1 could be used as a marker to indicate the degree of immune reaction induced by biomaterials.

  16. Quantitative Microstructural Characterization of Thick Aluminum Plates Heavily Deformed Using Equal Channel Angular Extrusion

    DEFF Research Database (Denmark)

    Mishin, Oleg; Segal, V.M.; Ferrasse, S.

    2012-01-01

    A detailed quantitative analysis of the microstructure has been performed in three orthogonal planes of 15-mm-thick aluminum plates heavily deformed via two equal channel angular extrusion (ECAE) routes. One route was a conventional route A with no rotation between passes. Another route involved...... sequential 90 deg rotations about the normal direction (ND) between passes. The microstructure in the center of these plates, and especially the extent of microstructural heterogeneity, has been characterized quantitatively and compared with that in bar samples extruded via either route A or route Bc with 90...... Bc. © The Minerals, Metals & Materials Society and ASM International 2012...

  17. Study of the effects of 1-MCP to blueberry under cold storage

    Science.gov (United States)

    Tao, Shenchen; Chu, Huailiang; Chen, Xiaomin; Yuan, Huwei; Qiu, Lingling; Zhao, Liang; Yan, Daoliang; Zheng, Bingsong

    2017-04-01

    Blueberry is one of the thinnest exocarp fruits in the world, which is difficult to keep fresh due to the special structure of its skin. 1-Methlcyclopropene (1-MCP) is able to combine with ethylene(ETH) receptor. In this study we investigated the effect of 1-MCP on rotting rate, weight loss ratio, soluble sugar content, titratable acid content, antioxidant enzyme activities and malondialdehyde (MDA) content in blueberry (Vaccinium corymbosun ‘O Neal’ and ‘North Road’) under cold storage. 1-MCP reduced the rotting rate, weight loss ratio and MDA content, while keeping high-leveled stability in antioxidant enzyme activities, soluble sugar content and titratable acid content. These results showed the role of 1-MCP in alleviating the negative effects of blueberry and suggested that 1-MCP could be used as a preservative for keeping thin exocarp fruit in fresh.

  18. Understanding the dynamic performance of microchannel plates in pulsed mode

    International Nuclear Information System (INIS)

    Ray Thomas; Ming Wu; Nathan Joseph; Craig Kruschwitz; Gregroy A. Rochau

    2007-01-01

    The dynamic performance of a microchannel plate (MCP) is highly dependent on the high-voltage waveforms that are applied to it. Impedance mismatches in MCP detectors can significantly vary the waveforms on the MCP compared to the input pulses. High-voltage pulse waveforms launched onto surface coatings on the MCPs have historically been difficult and expensive to measure. Over the past few years, we have developed and tested techniques utilizing probes to measure the voltage propagation on the surface of MCPs. Square and Gaussian pulses with widths ranging from 200 ps to 2 ns have been applied. We have investigated the effects of coating thickness, microstrip width, and openended versus terminated strips. These data provide a wealth of knowledge that is enabling a better understanding of images recorded with these devices. This presentation discusses a method for measuring voltage profiles on the surface of the MCP and presents Monte Carlo simulations of the optical gate profiles based on the measured waveforms. Excellent agreement in the optical gate profiles have been achieved between the simulations and the experimental measurements using a short-pulse ultraviolet laser

  19. Readout for a large area neutron sensitive microchannel plate detector

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yiming [Department of Engineering Physics, Tsinghua University, Beijing (China); Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education, Beijing (China); Yang, Yigang, E-mail: yangyigang@mail.tsinghua.edu.cn [Department of Engineering Physics, Tsinghua University, Beijing (China); Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education, Beijing (China); Wang, Xuewu; Li, Yuanjing [Department of Engineering Physics, Tsinghua University, Beijing (China); Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education, Beijing (China)

    2015-06-01

    A neutron sensitive microchannel plate (MCP) detector was developed for neutron imaging on the beamline of a compact pulsed hadron source (CPHS). The detector was set up with a Wedge-and-Strip Anode (WSA) and a delay line anode readout to compare the spatial resolution and throughput with these two anodes. Tests show that the WSA readout is suitable for small area imaging with a spatial resolution of 200 μm with low energy X-rays in a 50 mm diameter MCP–WSA assembly. However, the spatial resolution deteriorated to ~2 mm in a 106 mm diameter MCP–WSA assembly because the noise caused by the parasitic capacitance is 10 times larger in the larger assembly than in the 50 mm diameter assembly. A 120 mm by 120 mm delay line anode was then used for the 106 mm MCP readout. The spatial resolution was evaluated for various voltages applied to the MCP V-stack, various readout voltages and various distances between the MCP V-stack rear face and the delay line. The delay line readout had resolutions of 65.6 μm in the x direction and 63.7 μm in the y direction and the throughput was greater than 600 kcps. The MCP was then used to acquire a neutron image of an USAF1951 Gd-mask.

  20. Research on mechanism of the large-amplitude and narrow-band vibration of a flexible flat plate in the rectangular channel

    Energy Technology Data Exchange (ETDEWEB)

    Liu Lifang, E-mail: liu_lifang1106@yahoo.cn [School of Nuclear Science and Engineering, North China Electric Power University, Zhuxinzhuang, Dewai, Beijing 102206 (China); State Nuclear Power Software Development Center, Building 1, Compound No. 29, North Third Ring Road, Xicheng District, Beijing 100029 (China); Lu Daogang [School of Nuclear Science and Engineering, North China Electric Power University, Zhuxinzhuang, Dewai, Beijing 102206 (China)

    2012-09-15

    Highlights: Black-Right-Pointing-Pointer The large amplitude and narrow-band vibration experiment was performed. Black-Right-Pointing-Pointer The added mass theory was used to analyze the test plates' natural vibration characteristics in static water. Black-Right-Pointing-Pointer The occurring condition of the large amplitude and narrow band vibration was investigated. Black-Right-Pointing-Pointer The large amplitude and narrow-band vibration mechanism was investigated. - Abstract: Further experiments and theoretical analysis were performed to investigate mechanism of the large-amplitude and narrow-band vibration behavior of a flexible flat plate in a rectangular channel. Test plates with different thicknesses were adopted in the FIV experiments. The natural vibration characteristics of the flexible flat plates in air were tested, and the added mass theory of column was used to analyze the flexible flat plates' natural vibration characteristics in static water. It was found that the natural vibration frequency of a certain test plate in static water is approximately within the main vibration frequency band of the plate when it was induced to vibrate with the large-amplitude and narrow-band in the rectangular channel. It can be concluded that the harmonic between the flowing fluid and the vibrating plate is one of the key reasons to induce the large-amplitude and narrow-band vibration phenomenon. The occurring condition of the phenomenon and some important narrow-band vibration characteristics of a foursquare fix-supported flexible flat plate were investigated.

  1. Testing micro-channel plate detectors for the particle identification upgrade of LHCb

    CERN Document Server

    Castillo Garcia, L

    2012-01-01

    The TORCH, Time of internally Reflected Cherenkov Light, is proposed for the high luminosity upgrade of the LHCb experiment. The detector combines Time-of-Flight and Cherenkov techniques to achieve positive pi/K/p separation on a >= 3 sigma level in the momentum range below 10 GeV/c. The required time resolution is <= 50 ps for single photon signal. In a preliminary R\\&D phase, we have shown that already commercially available micro-channel plate tubes with 8 x 8 channels fulfil the requirements. Timing properties of the tubes have been investigated with a pulsed laser diode in single photon regime. Key results from these laboratory tests are reported. An excellent timing resolution of <40 ps is achieved with an efficiency of similar to 90\\%. (C) 2011 Elsevier B.V. All rights reserved.

  2. The MCP-4/MCP-1 ratio in plasma is a candidate circadian biomarker for chronic post-traumatic stress disorder

    Science.gov (United States)

    Dalgard, C; Eidelman, O; Jozwik, C; Olsen, C H; Srivastava, M; Biswas, R; Eudy, Y; Rothwell, S W; Mueller, G P; Yuan, P; Drevets, W C; Manji, H K; Vythlingam, M; Charney, D S; Neumeister, A; Ursano, R J; Jacobowitz, D M; Pollard, H B; Bonne, O

    2017-01-01

    Post-traumatic stress disorder (PTSD) is psychiatric disease, which can occur following exposure to traumatic events. PTSD may be acute or chronic, and can have a waxing and waning course of symptoms. It has been hypothesized that proinflammatory cytokines and chemokines in the cerebrospinal fluid (CSF) or plasma might be mediators of the psychophysiological mechanisms relating a history of trauma exposure to changes in behavior and mental health disorders, and medical morbidity. Here we test the cytokine/chemokine hypothesis for PTSD by examining levels of 17 classical cytokines and chemokines in CSF, sampled at 0900 hours, and in plasma sampled hourly for 24 h. The PTSD and healthy control patients are from the NIMH Chronic PTSD and healthy control cohort, initially described by Bonne et al. (2011), in which the PTSD patients have relatively low comorbidity for major depressive disorder (MDD), drug or alcohol use. We find that in plasma, but not CSF, the bivariate MCP4 (CCL13)/ MCP1(CCL2) ratio is ca. twofold elevated in PTSD patients compared with healthy controls. The MCP-4/MCP-1 ratio is invariant over circadian time, and is independent of gender, body mass index or the age at which the trauma was suffered. By contrast, MIP-1β is a candidate biomarker for PTSD only in females, whereas TARC is a candidate biomarker for PTSD only in males. It remains to be discovered whether these disease-specific differences in circadian expression for these specific immune signaling molecules are biomarkers, surrogates, or drivers for PTSD, or whether any of these analytes could contribute to therapy. PMID:28170001

  3. Flow patterns and heat transfer characteristics of flat plate pulsating heat pipes with various asymmetric and aspect ratios of the channels

    International Nuclear Information System (INIS)

    Jang, Dong Soo; Lee, Joo Seong; Ahn, Jae Hwan; Kim, Dongwoo; Kim, Yongchan

    2017-01-01

    Highlights: • Flat plate pulsating heat pipes with asymmetric and aspect ratios were tested. • Flow patterns were investigated according to channel geometry and flow condition. • Heat transfer characteristics were analyzed with various heat inputs. • Optimum asymmetric and aspect ratios were suggested for maximum thermal performance. - Abstract: The thermal performance of flat plate pulsating heat pipes (PHPs) in compact electronic devices can be improved by adopting asymmetric channels with increased pressure differences and an unbalanced driving force. The objective of this study is to investigate the heat transfer characteristics of flat plate PHPs with various asymmetric ratios and aspect ratios in the channels. The thermal performance and flow pattern of the flat plate PHPs were measured by varying the asymmetric ratio from 1.0 to 4.0, aspect ratio from 2.5 to 5.0, and heat input from 2 to 28 W. The effects of the asymmetric ratio and aspect ratio on the thermal resistance were analyzed with the measured evaporator temperature and flow patterns at various heat inputs. With heat inputs of 6 W and 12 W, the optimum asymmetric ratio and aspect ratio for the flat plate PHPs were determined to be 4.0 and 2.5, respectively. With the heat input of 18 W, the optimum asymmetric ratio and aspect ratio were determined to be 1.5 and 2.5, respectively.

  4. Thioredoxin reductase 1 upregulates MCP-1 release in human endothelial cells

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Zhen-Bo [Institute of Biophysics, Chinese Academy of Sciences, and Graduate School of the Chinese Academy of Sciences, Beijing (China); Shen, Xun, E-mail: shenxun@sun5.ibp.ac.cn [Institute of Biophysics, Chinese Academy of Sciences, and Graduate School of the Chinese Academy of Sciences, Beijing (China)

    2009-09-04

    To know if thioredoxin reductase 1 (TrxR1) plays a role in antioxidant defense mechanisms against atherosclerosis, effect of TrxR1 on expression/release of monocyte chemoattractant protein (MCP-1) was investigated in activated human endothelial-like EAhy926 cells. The MCP-1 release and expression, cellular generation of reactive oxygen species (ROS), nuclear translocation and DNA-binding activity of NF-{kappa}B subunit p65 were assayed in cells either overexpressing recombinant TrxR1 or having their endogenous TrxR1 knocked down. It was found that overexpression of TrxR1 enhanced, while knockdown of TrxR1 reduced MCP-1 release and expression. Upregulation of MCP-1 by TrxR1 was associated with increasing generation of intracellular ROS generation, enhanced nuclear translocation and DNA-binding activity of NF-{kappa}B. Assay using NF-{kappa}B reporter revealed that TrxR1 upregulated transcriptional activity of NF-{kappa}B. This study suggests that TrxR1 enhances ROS generation, NF-{kappa}B activity and subsequent MCP-1 expression in endothelial cells, and may promote rather than prevent vascular endothelium from forming atherosclerotic plaque.

  5. Associations Between Deceased-Donor Urine MCP-1 and Kidney Transplant Outcomes

    Directory of Open Access Journals (Sweden)

    S.G. Mansour

    2017-07-01

    Discussion: Donor uMCP-1 concentrations were modestly associated with higher recipient 6-month eGFR in those without DGF. However, the results suggest that donor uMCP-1 has minimal clinical utility given no associations with graft failure.

  6. Analytical modeling of a sandwiched plate piezoelectric transformer-based acoustic-electric transmission channel.

    Science.gov (United States)

    Lawry, Tristan J; Wilt, Kyle R; Scarton, Henry A; Saulnier, Gary J

    2012-11-01

    The linear propagation of electromagnetic and dilatational waves through a sandwiched plate piezoelectric transformer (SPPT)-based acoustic-electric transmission channel is modeled using the transfer matrix method with mixed-domain two-port ABCD parameters. This SPPT structure is of great interest because it has been explored in recent years as a mechanism for wireless transmission of electrical signals through solid metallic barriers using ultrasound. The model we present is developed to allow for accurate channel performance prediction while greatly reducing the computational complexity associated with 2- and 3-dimensional finite element analysis. As a result, the model primarily considers 1-dimensional wave propagation; however, approximate solutions for higher-dimensional phenomena (e.g., diffraction in the SPPT's metallic core layer) are also incorporated. The model is then assessed by comparing it to the measured wideband frequency response of a physical SPPT-based channel from our previous work. Very strong agreement between the modeled and measured data is observed, confirming the accuracy and utility of the presented model.

  7. Thermal-hydraulic analysis under partial loss of flow accident hypothesis of a plate-type fuel surrounded by two water channels using RELAP5 code

    Directory of Open Access Journals (Sweden)

    Itamar Iliuk

    2016-01-01

    Full Text Available Thermal-hydraulic analysis of plate-type fuel has great importance to the establishment of safety criteria, also to the licensing of the future nuclear reactor with the objective of propelling the Brazilian nuclear submarine. In this work, an analysis of a single plate-type fuel surrounding by two water channels was performed using the RELAP5 thermal-hydraulic code. To realize the simulations, a plate-type fuel with the meat of uranium dioxide sandwiched between two Zircaloy-4 plates was proposed. A partial loss of flow accident was simulated to show the behavior of the model under this type of accident. The results show that the critical heat flux was detected in the central region along the axial direction of the plate when the right water channel was blocked.

  8. Thermal-hydraulic behavior of physical quantities at critical velocities in a nuclear research reactor core channel using plate type fuel

    Directory of Open Access Journals (Sweden)

    Sidi Ali Kamel

    2012-01-01

    Full Text Available The thermal-hydraulic study presented here relates to a channel of a nuclear reactor core. This channel is defined as being the space between two fuel plates where a coolant fluid flows. The flow velocity of this coolant should not generate vibrations in fuel plates. The aim of this study is to know the distribution of the temperature in the fuel plates, in the cladding and in the coolant fluid at the critical velocities of Miller, of Wambsganss, and of Cekirge and Ural. The velocity expressions given by these authors are function of the geometry of the fuel plate, the mechanical characteristics of the fuel plate’s material and the thermal characteristics of the coolant fluid. The thermal-hydraulic study is made under steady-state; the equation set-up of the thermal problem is made according to El Wakil and to Delhaye. Once the equation set-up is validated, the three critical velocities are calculated and then used in the calculations of the different temperature profiles. The average heat flux and the critical heat flux are evaluated for each critical velocity and their ratio reported. The recommended critical velocity to be used in nuclear channel calculations is that of Wambsganss. The mathematical model used is more precise and all the physical quantities, when using this critical velocity, stay in safe margins.

  9. Pós colheita de bananas-maçã submetidas ao 1-MCP e armazenadas á temperatura ambiente Postharvest of 'apple' banana submetted to 1-MCP and storage in room temperature

    Directory of Open Access Journals (Sweden)

    Ana Carla Marque Pinheiro

    2006-04-01

    Full Text Available Bananas da cultivar Maçã foram adquiridas no estádio dois de coloração da casca (verde maturos e submetidas à ação de 1-MCP. O 1-MCP foi aplicado por 12 horas nas seguintes concentrações: 0 (controle, 50, 100, 150, 200 hL.L-1. Após aplicação, os frutos foram armazenados à temperatura ambiente (temperatura média 20ºC ± 1 e umidade relativa 80% ± 5 e avaliados à medida que atingiam os graus 3, 5 e 7 de coloração da casca. O tratamento com 1-MCP atrasou o início do amadurecimento de bananas-maçã armazenadas sob temperatura ambiente, baseado nas primeiras mudanças de coloração da casca. A aplicação de 1-MCP em bananas-maçã, ditou maiores valores de perda de massa e relação polpa/casca (nos graus 5 e 7 de coloração da casca. O 1-MCP, nas doses 100, 150 e 200 hL.L-1 de 1-MCP promoveu desverdecimento desuniforme e tonalidade avermelhada na casca. O tratamento 50 hL.L-1 de 1-MCP é o mais adequado, por promover a extensão da vida pós-colheita de bananas-maçã da cultivar armazenadas sob temperatura ambiente sem afetar a coloração da casca dos frutos, apresentando qualidade, baseando-se na cor da casca, firmeza, acidez titulável, pH e sólidos solúveis, semelhante ao controle.Mature green 'Apple' bananas were submitted to five concentrations of 1-MCP (0, 50, 100, 150 and 200 hL.L-1 for 12 hours. After treatment, the fruits were stored at room temperature (20ºC ± 1 and 80% ± 5 RH and analyzed at 3,5 and 7 color degree of peel. The treatment with 1-MCP delayed the start of the ripening based in the first changes of peel color. The treatment of 'Apple' bananas with 1-MCP promoted higher values of mass loss and pulp/peel ratio (5 and 7 degrees of color peel. The fruits treated with 100, 150 and 200 nL.L-1 of 1-MCP showed heterogeneous degreening and development of red color on the peel. 1-MCP at 50 nL.L-1 was the most appropriated treatment for promoting the extension of postharvest life of 'Apple' bananas stored

  10. Use of Large Surface MicroChannel Plates for the Tagging of Intermediate Energy Exotic Beams

    Energy Technology Data Exchange (ETDEWEB)

    Lombardo, I., E-mail: ilombardo@lns.infn.it [Dipartimento di Fisica, Universita di Catania, Catania (Italy); INFN Laboratori Nazionali del Sud, Catania (Italy); Amorini, F. [INFN Laboratori Nazionali del Sud, Catania (Italy); Cardella, G. [INFN, Sezione di Catania, Catania (Italy); Cavallaro, S. [Dipartimento di Fisica, Universita di Catania, Catania (Italy); INFN Laboratori Nazionali del Sud, Catania (Italy); De Filippo, E. [INFN, Sezione di Catania, Catania (Italy); Geraci, E.; Grassi, L. [Dipartimento di Fisica, Universita di Catania, Catania (Italy); INFN, Sezione di Catania, Catania (Italy); La Guidara, E. [INFN, Sezione di Catania, Catania (Italy); Centro Siciliano di Fisica Nucleare e Struttura della Materia, Catania (Italy); Lanzalone, G. [INFN Laboratori Nazionali del Sud, Catania (Italy); Libera Universita Kore, Enna (Italy); Pagano, A.; Papa, M.; Pirrone, S. [INFN, Sezione di Catania, Catania (Italy); Politi, G. [Dipartimento di Fisica, Universita di Catania, Catania (Italy); INFN, Sezione di Catania, Catania (Italy); Porto, F.; Rizzo, F.; Russotto, P. [Dipartimento di Fisica, Universita di Catania, Catania (Italy); INFN Laboratori Nazionali del Sud, Catania (Italy); Verde, G. [INFN, Sezione di Catania, Catania (Italy); Vigilante, M. [INFN, Sezione di Napoli and Dipartimento di Fisica, Universita Federico II di Napoli (Italy)

    2011-06-15

    We show the properties of the tagging system for exotic beams coupled to the CHIMERA detector. In particular, the characteristics of a newly developed large surface MicroChannel Plate will be discussed. Timing and efficiency of this instrument have been investigated. Preliminary results of tests performed with radioactive beams and alpha sources are presented.

  11. Root-Contact/Pressure-Plate Assembly For Hydroponic System

    Science.gov (United States)

    Morris, Carlton E.; Loretan, Philip A.; Bonsi, Conrad K.; Hill, Walter A.

    1994-01-01

    Hydroponic system includes growth channels equipped with rootcontact/pressure-plate assemblies. Pump and associated plumbing circulate nutrient liquid from reservoir, along bottom of growth channels, and back to reservoir. Root-contact/pressure-plate assembly in each growth channel stimulates growth of roots by applying mild contact pressure. Flat plate and plate connectors, together constitute pressure plate, free to move upward to accommodate growth of roots. System used for growing sweetpotatoes and possibly other tuber and root crops.

  12. Effects of equal channel angular extrusion on microstructure, strength and ballistic performance of AA5754 plates

    DEFF Research Database (Denmark)

    Mishin, Oleg; Hong, Chuanshi; Toftegaard, Helmuth Langmaack

    2014-01-01

    The microstructure, hardness, tensile properties and ballistic performance have been investigated in thick plates of the AA5754 alloy both in a coarse-grained as-received condition and after 4 passes of equal channel angular extrusion (ECAE) conducted at elevated temperatures. It is found that ECAE...

  13. MCP-1 Levels are Associated with Cardiac Remodeling but not with Resistant Hypertension.

    Science.gov (United States)

    Ritter, Alessandra Mileni Versuti; Faria, Ana Paula Cabral de; Sabbatini, Andrea; Corrêa, Nathalia Batista; Brunelli, Veridiana; Modolo, Rodrigo; Moreno, Heitor

    2017-04-01

    Hypertension is a chronic, low-grade inflammation process associated with the release of cytokines and development of target organ damage. Deregulated monocyte chemoattractant protein-1 (MCP-1) levels have been associated with high blood pressure and cardiovascular complications; however, the mechanisms involved are complex and not fully understood. This study aimed to compare the levels of MCP-1 in patients with resistant (RH) versus mild-to-moderate (HTN) hypertension and their association with the presence or absence of left ventricular hypertrophy (LVH) in all hypertensive subjects. We enrolled 256 hypertensive subjects: 120 RH and 136 HTN, investigating the relationship between circulating MCP-1 levels and blood pressure, biochemical data, hematologic profile, and cardiac damage within the RH and HTN groups. Plasma MCP-1 levels were measured by ELISA and LVH was assessed by echocardiography. We found no difference in MCP-1 levels between RH and HTN subjects. On the other hand, we encountered lower MCP-1 levels in patients with LVH (105 pg/mL [100 - 260 pg/mL] versus 136 pg/mL (100 - 200 pg/mL), p = 0.005, respectively] compared with those without LVH. A logistic regression model adjusted for body mass index (BMI), age, race, aldosterone levels, and presence of diabetes and RH demonstrated that median levels of MCP-1 (2.55 pg/mL [1.22 - 5.2 pg/mL], p = 0.01) were independently associated with LVH in the entire hypertensive population. Since MCP-1 levels were similar in both RH and HTN subjects and decreased in hypertensive patients with existing LVH, our study suggests a possible downregulation in MCP-1 levels in hypertensive individuals with LVH, regardless of hypertension strata. A hipertensão arterial é um processo crônico de baixo grau inflamatório, associado com liberação de citocinas e desenvolvimento de lesão em órgãos-alvo. A desregulação dos níveis de proteína quimiotática de monócitos-1 (MCP-1) tem sido associada com elevação da press

  14. Melanocyte pigmentation inversely correlates with MCP-1 production and angiogenesis-inducing potential.

    Science.gov (United States)

    Adini, Irit; Adini, Avner; Bazinet, Lauren; Watnick, Randolph S; Bielenberg, Diane R; D'Amato, Robert J

    2015-02-01

    The incidence of certain angiogenesis-dependent diseases is higher in Caucasians than in African Americans. Angiogenesis is amplified in wound healing and cornea models in albino C57 mice compared with black C57 mice. Moreover, mouse and human melanocytes with low pigmentation stimulate endothelial cell (EC) proliferation and migration in vitro more than melanocytes with high pigmentation. This effect is due, in part, to the secretion of an angiogenic protein called fibromodulin (FMOD) from lowly pigmented melanocytes. Herein, we expand upon the mechanism contributing to increased angiogenesis in lighter skin and report that monocyte chemotactic protein-1 (MCP-1) is secreted by nonpigmented mouse melanocytes by 5- to 10-fold more than pigmented melanocytes. MCP-1 protein stimulates EC proliferation and migration in vitro and angiogenesis in vivo. Mechanistic studies determine that FMOD is upstream of MCP-1 and promotes its secretion from both melanocytes and activated ECs via stimulation of NF-κB activity. Mice injected with FMOD-neutralizing antibodies show 2.3-fold decreased levels of circulating MCP-1. Human studies confirmed that, on average, Caucasians have 2-fold higher serum levels of MCP-1 than African Americans. Taken together, this study implicates the FMOD/MCP-1 pathway in the regulation of angiogenesis by local melanocytes and suggests that melanogenic activity may protect against aberrant angiogenic diseases. © FASEB.

  15. Increased MCP-1 gene expression in monocytes of severe OSA patients and under intermittent hypoxia.

    Science.gov (United States)

    Chuang, Li-Pang; Chen, Ning-Hung; Lin, Yuling; Ko, Wen-Shan; Pang, Jong-Hwei S

    2016-03-01

    Obstructive sleep apnea (OSA) is known to be a risk factor of coronary artery disease. Monocyte chemoattractant protein-1 (MCP-1), as a critical factor for monocyte infiltration, is known to play a role in the development of atherosclerosis. This study aimed to investigate the effect of intermittent hypoxia, the hallmark of OSA, on the MCP-1 expression of monocytes. Peripheral blood was sampled from 61 adults enrolled for suspected OSA. RNA was prepared from the isolated monocytes for the analysis of MCP-1. The effect of in vitro intermittent hypoxia on the regulation and function of MCP-1 was investigated on THP-1 monocytic cells and human monocytes. The mRNA and secreted protein levels were investigated by RT/real-time PCR and enzyme-linked immunosorbent assay, respectively. Monocytic MCP-1 gene expression was found to be increased significantly in severe OSA patients. In vitro intermittent hypoxia was demonstrated to increase the mRNA and protein expression levels of MCP-1 dose- and time-dependently in THP-1 monocytic cells. The MCP-1 mRNA expression in monocytes isolated from OSA patient was induced to a much higher level compared to that from normal control. Pre-treatment with inhibitor for p42/44 MAPK or p38 MAPK suppressed the activation of MCP-1 expression by intermittent hypoxia. This is the first study to demonstrate the increase of MCP-1 gene expression in monocytes of severe OSA patients. In addition, monocytic MCP-1 gene expression can be induced under intermittent hypoxia.

  16. Atraso do amadurecimento de banana 'Maçã' pelo 1-MCP, aplicado previamente à refrigeração Ripening delay of 'Apple' banana submitted to 1-MCP, prevoiously applied to refrigeration

    Directory of Open Access Journals (Sweden)

    Gustavo Costa Almeida

    2006-08-01

    Full Text Available O objetivo deste trabalho foi avaliar o efeito de diferentes períodos de exposição da banana 'Maçã' a 50 ppb de 1-MCP (0; 3; 6; 9; 12 e 24 horas sobre sua vida pós-colheita e qualidade. Após exposição ao 1-MCP, os frutos verde-maturos foram armazenados por 30 dias em câmaras com temperatura de 13ºC ± 0,5 e umidade relativa de 95%. Em seguida, as bananas foram armazenadas à temperatura de 20ºC ± 1, até amarelecimento completo da casca. A exposição de banana 'Maçã' a 50 ppb de 1-MCP, por 9 horas, retardou em 7 dias o seu amadurecimento, em comparação a frutos não expostos ao 1-MCP, após 30 dias de armazenamento refrigerado (13ºC, sem prejuízos à sua aparência e composição química. A exposição de banana 'Maçã' a 50 ppb de 1-MCP, por 3 e 6 horas, não estendeu sua vida pós-colheita, tampouco alterou sua composição química. Embora a exposição de banana 'Maçã' a 50 ppb de 1-MCP, por 12 e 24 horas, tenha retardado o seu amadurecimento, promoveu alterações indesejáveis na casca do fruto. Logo, a aplicação de 50 ppb de 1-MCP, por 9 horas, antes da refrigeração, constitui-se numa alternativa viável para prolongar o período de comercialização da banana.The aim of this work was to evaluate 'Apple' banana different periods exposure effect to 50 ppb of 1-MCP (0, 3, 6, 9 and 24 hours on its postharvest life and quality. Mature-green fruits were stored for 30 days in chambers at 13ºC + 0,5 and relative humidity 95%, after exposure to 1-MCP. Then, the bananas were stored at 20ºC + 1 until peel complete yellowing. 'Apple' banana to 50 ppb of 1-MCP exposure during 9 hours delayed in seven days the fruit ripening, comparing to fruit control, after 30 days of cool storage (13ºC, without changing its appearance and chemical composition. The exposure of 'Apple' banana to 50 ppb of 1-MCP for 3 and 6 hours did not extend its postharvest life; neither changed its chemical composition. Although the exposure of

  17. RETARDAMENTO DA MATURAÇÃO DE MAÇÃS 'FUJI' PELO TRATAMENTO COM 1-MCP E MANEJO DA TEMPERATURA DELAYING 'FUJI' APPLE RIPENING BY 1-MCP TREATMENT AND MANAGEMENT OF STORAGE TEMPERATURE

    Directory of Open Access Journals (Sweden)

    LUIZ CARLOS ARGENTA

    2001-08-01

    Full Text Available Maçãs cv. Fuji foram tratadas com 42 mimol·m-3 de 1-metilciclopropeno (1-MCP por 24 h a 20°C, um dia após a colheita, e então armazenadas a 0; 10 ou 20ºC por 70 dias. Tratamento com 1-MCP efetivamente retardou a maturação de maçãs 'Fuji'. 1-MCP reduziu a taxa respiratória dos frutos mantidos a 10 e 20ºC e inibiu a produção de etileno dos frutos mantidos nas três temperaturas de armazenagem. Frutos tratados com 1-MCP e armazenados a 20ºC exibiram taxas respiratórias similares ou inferiores àquelas de frutos-controle armazenados a 10ºC. Quando armazenados a 10 ou 20ºC, frutos tratados com 1-MCP preservaram mais a firmeza da polpa e a acidez titulável e exibiram menor amarelecimento da epiderme que frutos-controle. Entretanto, não houve benefícios significativos do tratamento 1-MCP sobre a conservação da qualidade dos frutos armazenados a 0ºC no período de 70 dias após a colheita. Os resultados indicam que o tratamento com 1-MCP pode ser uma estratégia para o aumento da conservação de maçãs cv. Fuji durante o transporte e a distribuição sob 10 ou 20ºC. O prolongamento da armazenagem a 20ºC por período superior a 40 dias pode ser limitado pelo murchamento dos frutos e desenvolvimento de podridões.'Fuji' apples were treated with 42 mumol·m-3 of 1-methylcyclopropene (1-MCP for 24 h at 20°C then stored at 0, 10 or 20 ºC for 70 days. MCP treatment reduced respiration on fruit held at 10 and 20 ºC and inhibited ethylene production regardless of storage temperature. Treated fruits held at 20ºC presented respiration rate similar to those of untreated fruits held at 10ºC. For fruit held at 10 or 20ºC, MCP treatment inhibited softening, loss of acidity and color changes on fruit surface. However, there was no considerable benefit of 1-MCP treatment on maintenance of fruit quality during short-term (70 days and storage at 0ºC. Results indicated that 1-MCP is an effective mean to delay ripening and to retain

  18. Relationships between serum MCP-1 and subclinical kidney disease: African American-Diabetes Heart Study

    Directory of Open Access Journals (Sweden)

    Murea Mariana

    2012-11-01

    Full Text Available Abstract Background Monocyte chemoattractant protein-1 (MCP-1 plays important roles in kidney disease susceptibility and atherogenesis in experimental models. Relationships between serum MCP-1 concentration and early nephropathy and subclinical cardiovascular disease (CVD were assessed in African Americans (AAs with type 2 diabetes (T2D. Methods Serum MCP-1 concentration, urine albumin:creatinine ratio (ACR, estimated glomerular filtration rate (eGFR, and atherosclerotic calcified plaque (CP in the coronary and carotid arteries and infrarenal aorta were measured in 479 unrelated AAs with T2D. Generalized linear models were fitted to test for associations between MCP-1 and urine ACR, eGFR, and CP. Results Participants were 57% female, with mean ± SD (median age 55.6±9.5 (55.0 years, diabetes duration 10.3±8.2 (8.0 years, urine ACR 149.7±566.7 (14.0 mg/g, CKD-EPI eGFR 92.4±23.3 (92.0 ml/min/1.73m2, MCP-1 262.9±239.1 (224.4 pg/ml, coronary artery CP 280.1±633.8 (13.5, carotid artery CP 47.1±132.9 (0, and aorta CP 1616.0±2864.0 (319.0. Adjusting for age, sex, smoking, HbA1c, BMI, and LDL, serum MCP-1 was positively associated with albuminuria (parameter estimate 0.0021, P=0.04 and negatively associated with eGFR (parameter estimate −0.0003, P=0.001. MCP-1 remained associated with eGFR after adjustment for urine ACR. MCP-1 levels did not correlate with the extent of CP in any vascular bed, HbA1c or diabetes duration, but were positively associated with BMI. No interaction between BMI and MCP-1 was detected on nephropathy outcomes. Conclusions Serum MCP-1 levels are associated with eGFR and albuminuria in AAs with T2D. MCP-1 was not associated with subclinical CVD in this population. Inflammation appears to play important roles in development and/or progression of kidney disease in AAs.

  19. MCP-1 in urine as biomarker of disease activity in Systemic Lupus Erythematosus.

    Science.gov (United States)

    Barbado, Julia; Martin, Debora; Vega, Luisa; Almansa, Raquel; Gonçalves, Lisbeth; Nocito, Mercedes; Jimeno, Antonio; Ortiz de Lejarazu, Raúl; Bermejo-Martin, Jesus F

    2012-11-01

    Conventional clinical parameters are not sensitive or specific enough for detecting ongoing disease activity in the Systemic Lupus Erythematosus (SLE). Measurement of cytokines in urine is an encouraging approach to detection of early flares in this disease. Here we have profiled 27 different cytokines, chemokines and celular growth factors in the urine of 48 patients previously diagnosed of SLE as potential biomarkers of disease activity. Correlation analysis with Bonferroni correction showed that MCP-1 was the only immune mediator which levels in urine correlated directly with the SLE Disease Activity Index 2000 (SLEDAI-2K) score (correlation coefficient, p): MCP-1 (0.45,0.003). MCP-1 correlated inversely with levels of C3 complement protein in serum (-0.50,0.001). MCP-1 showed significant higher levels in patients with severe disease activity in comparison with those exhibiting mild activity. Levels of this chemokine were also higher in patients with severe disease activity in comparison with patients with inactive disease and healthy controls. Areas under receiver operating characteristic curves (AUROC) for detection of severe disease (SLEDAI⩾8) was as follows for MCP-1: [AUROC, (IC95%), p]: [0.81 (0.65-0.96) 0.003]. In addition, MCP-1 showed a good result in the AUROC analysis for detecting renal involvement [0.70 (0.52-0.87) 0.050]. When correlation analysis were repeated excluding those patients with active renal disease (n=14), levels of MCP-1 in urine kept on showing a significant positive association with SLEDAI-2K score. In conclusion, multiplex-based cytokine profiling in urine demonstrated the superiority of MCP-1 over a wide range of cytokines as biomarker of disease activity in SLE. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. JNK-induced MCP-1 production in spinal cord astrocytes contributes to central sensitization and neuropathic pain.

    Science.gov (United States)

    Gao, Yong-Jing; Zhang, Ling; Samad, Omar Abdel; Suter, Marc R; Yasuhiko, Kawasaki; Xu, Zhen-Zhong; Park, Jong-Yeon; Lind, Anne-Li; Ma, Qiufu; Ji, Ru-Rong

    2009-04-01

    Our previous study showed that activation of c-jun-N-terminal kinase (JNK) in spinal astrocytes plays an important role in neuropathic pain sensitization. We further investigated how JNK regulates neuropathic pain. In cultured astrocytes, tumor necrosis factor alpha (TNF-alpha) transiently activated JNK via TNF receptor-1. Cytokine array indicated that the chemokine CCL2/MCP-1 (monocyte chemoattractant protein-1) was strongly induced by the TNF-alpha/JNK pathway. MCP-1 upregulation by TNF-alpha was dose dependently inhibited by the JNK inhibitors SP600125 (anthra[1,9-cd]pyrazol-6(2H)-one) and D-JNKI-1. Spinal injection of TNF-alpha produced JNK-dependent pain hypersensitivity and MCP-1 upregulation in the spinal cord. Furthermore, spinal nerve ligation (SNL) induced persistent neuropathic pain and MCP-1 upregulation in the spinal cord, and both were suppressed by D-JNKI-1. Remarkably, MCP-1 was primarily induced in spinal cord astrocytes after SNL. Spinal administration of MCP-1 neutralizing antibody attenuated neuropathic pain. Conversely, spinal application of MCP-1 induced heat hyperalgesia and phosphorylation of extracellular signal-regulated kinase in superficial spinal cord dorsal horn neurons, indicative of central sensitization (hyperactivity of dorsal horn neurons). Patch-clamp recordings in lamina II neurons of isolated spinal cord slices showed that MCP-1 not only enhanced spontaneous EPSCs but also potentiated NMDA- and AMPA-induced currents. Finally, the MCP-1 receptor CCR2 was expressed in neurons and some non-neuronal cells in the spinal cord. Together, we have revealed a previously unknown mechanism of MCP-1 induction and action. MCP-1 induction in astrocytes after JNK activation contributes to central sensitization and neuropathic pain facilitation by enhancing excitatory synaptic transmission. Inhibition of the JNK/MCP-1 pathway may provide a new therapy for neuropathic pain management.

  1. HIGH-CURRENT COLD CATHODE FIELD EMISSION ARRAY FOR ELECTRON LENS APPLICATION

    Energy Technology Data Exchange (ETDEWEB)

    Hirshfield, Jay L

    2012-12-28

    During Phase I, the following goals were achieved: (1) design and fabrication of a novel, nano-dimensional CNT field emitter assembly for high current density application, with high durability; (2) fabrication of a ceramic based micro channel plate (MCP) and characterization of its secondary electron emission; and (3) characterizing the CNT/MCP cathode for high field emission and durability. As a result of these achievements, a relatively high current density of ~ 1.2 A/cm2 from a CNT cathode and single channel MCP were measured. The emission current was also extremely stable with a peak-to-peak variation of only 1.8%. The emission current could be further enhanced to meet requirements for electron lens applications by increasing the number of MCP channels. A calculation for maximum possible current density with a 1200 channel/cm2 MCP, placed over a cathode with 1200 uniformly functioning CNTs, would be ~1.46 kA/cm2, neglecting space charge limitations. Clearly this level of emission is far greater than what is needed for the electron lens application, but it does offer a highly comforting margin to account for sub-standard emitters and/or to allow the lesser challenge of building a cathode with fewer channels/cm2. A satisfactory goal for the electron lens application would be a controllable emission of 2-4 mA per channel in an ensemble of 800-1200 uniformly-functioning channels/cm2, and a cathode with overall area of about 1 cm2.

  2. Anti-inflammatory effect of resveratrol on TNF-α-induced MCP-1 expression in adipocytes

    International Nuclear Information System (INIS)

    Zhu Jian; Yong Wei; Wu Xiaohong; Yu Ying; Lv Jinghuan; Liu Cuiping; Mao Xiaodong; Zhu Yunxia; Xu Kuanfeng; Han Xiao; Liu Chao

    2008-01-01

    Chronic low-grade inflammation characterized by adipose tissue macrophage accumulation and abnormal cytokine production is a key feature of obesity and type 2 diabetes. Adipose-tissue-derived monocyte chemoattractant protein (MCP)-1, induced by cytokines, has been shown to play an essential role in the early events during macrophage infiltration into adipose tissue. In this study we investigated the effects of resveratrol upon both tumor necrosis factor (TNF)-α-induced MCP-1 gene expression and its underlying signaling pathways in 3T3-L1 adipoctyes. Resveratrol was found to inhibit TNF-α-induced MCP-1 secretion and gene transcription, as well as promoter activity, which based on down-regulation of TNF-α-induced MCP-1 transcription. Nuclear factor (NF)-κB was determined to play a major role in the TNF-α-induced MCP-1 expression. Further analysis showed that resveratrol inhibited DNA binding activity of the NF-κB complex and subsequently suppressed NF-κB transcriptional activity in TNF-α-stimulated cells. Finally, the inhibition of MCP-1 may represent a novel mechanism of resveratrol in preventing obesity-related pathologies

  3. Development of 10×10 Matrix-anode MCP-PMT

    Science.gov (United States)

    Yang, Jie; Li, Yongbin; Xu, Pengxiao; Zhao, Wenjin

    2018-02-01

    10×10 matrix-anode is developed by high-temperature co-fired ceramics (HTCC) technology. Based on the new matrix-anode, a new kind of photon counting imaging detector - 10×10 matrix-anode MCP-PMT is developed, and its performance parameters are tested. HTCC technology is suitable for the MCP-PMT's air impermeability and its baking process. Its response uniformity is better than the metal-ceramic or metal-glass sealing anode, and it is also a promising method to realize a higher density matrix-anode.

  4. Examination of the spatial-response uniformity of a microchannel-plate detector using a pulsed high-voltage electron gun

    International Nuclear Information System (INIS)

    Alumot, D; Kroupp, E; Fisher, A

    2014-01-01

    In this paper we describe an alternative method to examine the spatial-response uniformity of a microchannel-plate (MCP) detector to a ∼ 1 ns pulse of soft x-rays. The examination was performed by illuminating the MCP surface with energetic electrons rather than with x-rays. It is shown that the MCP features similar, yet not identical, response to pulses of soft x-ray photons or energetic electrons, making such examinations much simpler and less expensive. The building of the electron-gun system is relatively easy and inexpensive, and in addition to verifying the spatial uniformity of the response of the MCP to incoming particles and radiation, it can be used to detect damaged areas on the detector. A comparison between the results obtained using the electron-gun with those obtained using a laser-produced-plasma x-ray source, demonstrating the reliability of the method, is presented

  5. Detailed measurements and shaping of gate profiles for microchannel-plate-based X-ray framing cameras

    International Nuclear Information System (INIS)

    Landen, O.L.; Hammel, B.A.; Bell, P.M.; Abare, A.; Bradley, D.K.; Univ. of Rochester, NY

    1994-01-01

    Gated, microchannel-plate-based (MCP) framing cameras are increasingly used worldwide for x-ray imaging of subnanosecond laser-plasma phenomena. Large dynamic range (> 1,000) measurements of gain profiles for gated microchannel plates (MCP) are presented. Temporal profiles are reconstructed for any point on the microstrip transmission line from data acquired over many shots with variable delay. No evidence for significant pulse distortion by voltage reflections at the ends of the microstrip is observed. The measured profiles compare well to predictions by a time-dependent discrete dynode model down to the 1% level. The calculations do overestimate the contrast further into the temporal wings. The role of electron transit time dispersion in limiting the minimum achievable gate duration is then investigated by using variable duration flattop gating pulses. A minimum gate duration of 50 ps is achieved with flattop gating, consistent with a fractional transit time spread of ∼ 15%

  6. Aplicação de 1-MCP em caqui 'quioto' armazenado sob refrigeração e atmosfera controlada Effect of 1-MCP applied at different times during cold and Ca storage

    Directory of Open Access Journals (Sweden)

    Auri Brackmann

    2003-04-01

    Full Text Available O objetivo deste trabalho foi de avaliar o efeito do 1-MCP aplicado em diferentes épocas durante o armazenamento refrigerado (AR e em atmosfera controlada (AC sobre a qualidade do caqui cv. Quioto. O delineamento experimental utilizado foi o inteiramente casualizado, com quatro repetições de 30 frutos, e os tratamentos foram os seguintes: armazenamento refrigerado (AR; armazenamento refrigerado(AR + 1-MCP (1000ppb no início do armazenamento; armazenamento refrigerado(AR +1-MCP (1000ppb no final do armazenamento; armazenamento em atmosfera controlada (AC com 1kPa de O2 e AC 5kPa de CO2 e AC com 1kPa de O2 e 5kPa de CO2 + 1-MCP no fim do armazenamento, após 2 meses de armazenamento a -0,5ºC mais 5 dias de exposição dos frutos a 10ºC e 3 dias a 20ºC. No armazenamento refrigerado, o 1-MCP, aplicado tanto no início do armazenamento como no final, proporcionou maior firmeza de polpa. Para os parâmetros: sólidos solúveis totais, podridão e escurecimento da película, não houve diferença estatística entre os tratamentos. Conclui-se que a aplicação de 1-MCP, tanto no início como no final do armazenamento mantém elevada a firmeza de polpa.The objective of this work was to evaluate the effect of 1-MCP applied at different period during the cold storage (CS and in controlled atmosphere (CA on the quality of 'Quioto'. Persimmon. The experimental design was completely randomized with four replications of 30 fruits and the tested treatments were: cold storage (CS, cold storage + 1-MCP (1000ppb in the beginning of the storage, cold storage + 1-MCP (1000ppb in the end of the storage period; storage in controlled atmosphere (CA with 1kPa of O2 and 5kPa of CO2 and 1kPa of O2 and 5kPa of CO2 + 1-MCP in the end of the storage, after 2 months of storage at -0.5ºC, plus 5 days at 10ºC and 3 days at 20ºC. In the cooled storage, the 1-MCP, applied as in the beginning of the storage as in the end of the storage, provided greater pulp firmness

  7. Proximity focusing RICH with TOF capabilities

    International Nuclear Information System (INIS)

    Korpar, S.; Adachi, I.; Fujita, K.; Fukushima, T.; Gorisek, A.; Hayashi, D.; Iijima, T.; Ikado, T.; Ishikawa, T.; Kawai, H.; Kozakai, Y.; Krizan, P.; Kuratani, A.; Mazuka, Y.; Nakagawa, T.; Nishida, S.; Ogawa, S.; Pestotnik, R.; Seki, T.; Sumiyoshi, T.; Tabata, M.; Unno, Y.

    2007-01-01

    A proximity focusing RICH counter with a multi-channel micro-channel plate (MCP) PMT was tested as a time-of-flight counter. Cherenkov photons emitted in the radiator medium as well as in the entrance window of the PMT were used for the time-of-flight measurement, and an excellent performance of the counter could be demonstrated

  8. Channel follower leakage restrictor

    International Nuclear Information System (INIS)

    Williamson, H.E.; Smith, B.A.

    1977-01-01

    An improved means is provided to control coolant leakage between the flow channel and the lower tie plate of a nuclear fuel assembly. The means includes an opening in the lower tie plate and a movable element adjacent thereto. The coolant pressure within the tie plate biases the movable means toward the inner surface of the surrounding flow channel to compensate for any movement of the flow channel away from the lower tie plate to thereby control the leakage of coolant flow from the fuel assemblies to the spaces among the fuel assemblies of the core. 9 figures

  9. Role of MCP-1 in pleural effusion development in a carrageenan-induced murine model of pleurisy.

    Science.gov (United States)

    Lansley, Sally M; Cheah, Hui Min; Lee, Y C Gary

    2017-05-01

    Exudative pleural effusions affect over 1500 patients per million population each year. The pathobiology of pleural exudate formation remains unclear. Our recent study revealed monocyte chemotactic protein-1 (MCP-1) as a key driver of fibrinolytic-induced exudate effusion while another study found a role for MCP-1 in malignant effusion formation. In the present study, we further evaluated the role of MCP-1 in the development of pleural effusion in a mouse model of acute pleural inflammation. λ-Carrageenan (CAR) was injected into the pleural cavity of CD1 mice and pleural effusion volume measured up to 16 h post-injection. Pleural effusion and serum protein and MCP-1 concentrations were measured and differential cell counts performed in fluids. Mice were also treated with either intraperitoneal (i) anti-MCP-1 antibody or isotype control or (ii) an MCP-1 receptor (CCR2) antagonist or vehicle control 12 h prior to and at the time of CAR injection. Intrapleural CAR induced significant pleural fluid accumulation (300.0 ± 49.9 μL) in mice after 4 h. Pleural fluid MCP-1 concentrations were significantly higher than corresponding serum MCP-1 (144 603 ± 23 204 pg/mL vs 3703 ± 801 pg/mL, P pleural fluid formation was seen both with anti-MCP-1 antibody (median (interquartile range, IQR): 36 (0-168) μL vs controls 290 (70-436) μL; P = 0.02) or CCR2 antagonist (153 (30-222) μL vs controls 240 (151-331) μL, P = 0.0049). Blockade of MCP-1 activity significantly reduced inflammatory pleural effusion formation in a CAR model. Together with recent successes in MCP-1 blockade in other effusion formation models, our data strongly support clinical evaluation of MCP-1 antagonists as a novel approach to pleural fluid management. © 2016 Asian Pacific Society of Respirology.

  10. Three-dimensional supercapacitors composed of Ba{sub 0.65}Sr{sub 0.35}TiO{sub 3} (BST)/NiSi{sub 2}/silicon microchannel plates

    Energy Technology Data Exchange (ETDEWEB)

    Liu Tao; Zhang Huayan; Wang Fei; Shi Jing; Ci Pengliang [Laboratory of Polar Materials and Devices, Ministry of Education, and Department of Electronic Engineering, East China Normal University, 500 Dongchuan Road, Minhang District, Shanghai 200241 (China); Wang Lianwei, E-mail: lwwang@ee.ecnu.edu.cn [Laboratory of Polar Materials and Devices, Ministry of Education, and Department of Electronic Engineering, East China Normal University, 500 Dongchuan Road, Minhang District, Shanghai 200241 (China); Ge Shuli; Wang Qingjiang [Department of Chemistry, East China Normal University, Shanghai 200241 (China); Chu, Paul K. [Department of Physics and Material Sciences, City University of Hong Kong, Tat Chee Avenue, Kowloon (Hong Kong)

    2011-03-25

    Three-dimensional (3D) supercapacitors consisting of Ba{sub 0.65}Sr{sub 0.35}TiO{sub 3} (BST)/NiSi{sub 2}/silicon microchannel plate (MCP) stacked structure have been fabricated. The silicon MCP produced by electrochemical etching is utilized as a backbone of the 3D structure on which a nickel silicide current collector layer and Ba{sub 0.65}Sr{sub 0.35}TiO{sub 3} dielectric layer are deposited successively by electroless plating and the sol-gel method, respectively. The morphology and structure of the 3D BST/NiSi{sub 2}/Si-MCP structure are characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD) and the electrochemical properties are determined by cyclic voltammetry (CV) and chronopotentiometry. The structure exhibits excellent capacitive behavior with a maximum capacitance of 784 F g{sup -1}. After 700 charging/discharging cycles, the C{sub f} decreases slightly with only a 5.7% loss and is stable after more than 700 cycles. The BST/NiSi{sub 2}/Si-MCP 3D structure is a potential supercapacitor in industrial applications.

  11. Monocyte chemoattractant protein-1 (MCP-1 regulates macrophage cytotoxicity in abdominal aortic aneurysm.

    Directory of Open Access Journals (Sweden)

    Qiwei Wang

    Full Text Available AIMS: In abdominal aortic aneurysm (AAA, macrophages are detected in the proximity of aortic smooth muscle cells (SMCs. We have previously demonstrated in a murine model of AAA that apoptotic SMCs attract monocytes and other leukocytes by producing MCP-1. Here we tested whether infiltrating macrophages also directly contribute to SMC apoptosis. METHODS AND RESULTS: Using a SMC/RAW264.7 macrophage co-culture system, we demonstrated that MCP-1-primed RAWs caused a significantly higher level of apoptosis in SMCs as compared to control macrophages. Next, we detected an enhanced Fas ligand (FasL mRNA level and membrane FasL protein expression in MCP-1-primed RAWs. Neutralizing FasL blocked SMC apoptosis in the co-culture. In situ proximity ligation assay showed that SMCs exposed to primed macrophages contained higher levels of receptor interacting protein-1 (RIP1/Caspase 8 containing cell death complexes. Silencing RIP1 conferred apoptosis resistance to SMCs. In the mouse elastase injury model of aneurysm, aneurysm induction increased the level of RIP1/Caspase 8 containing complexes in medial SMCs. Moreover, TUNEL-positive SMCs in aneurysmal tissues were frequently surrounded by CD68(+/FasL(+ macrophages. Conversely, elastase-treated arteries from MCP-1 knockout mice display a reduction of both macrophage infiltration and FasL expression, which was accompanied by diminished apoptosis of SMCs. CONCLUSION: Our data suggest that MCP-1-primed macrophages are more cytotoxic. MCP-1 appears to modulate macrophage cytotoxicity by increasing the level of membrane bound FasL. Thus, we showed that MCP-1-primed macrophages kill SMCs through a FasL/Fas-Caspase8-RIP1 mediated mechanism.

  12. Functionalized Nano-Film Microchannel Plate: A Single High Aspect Ratio Device for High Resolution, Low Noise Astronomical Imaging, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation is to apply proven nano-film technology to enable Microchannel plate (MCP) devices to be manufactured on a range of insulating substrates and...

  13. VIDA COMERCIAL DE PITAHAYA AMARILLA TRATADA CON 1-MCP

    Directory of Open Access Journals (Sweden)

    LILIANA SERNA-COCK

    Full Text Available 1-metilciclopropeno (1-MCP, un inhibidor del etileno, ha sido utilizado para extender la vida comercial de diferentes frutas. El objetivo de este trabajo fue evaluar el efecto de la aplicación de soluciones acuosas de 10, 100 y 200 gL-1 de 1-MCP, con tiempos de exposición de 1, 5 y 10 minutos, sobre la vida comercial de pitahaya amarilla en estado de madurez 4. Durante 15 días de almacenamiento (25 ± 2°C y 75% de humedad relativa, se evaluaron cambios físicos como la pérdida de peso y la aparición de pardeamiento; y se midieron cambios químicos como sólidos solubles, pH, acidez e índice de madurez. Se presentaron diferencias significativas entre los tratamientos. Los resultados demostraron que aplicaciones de 200 gL-1 de 1-MCP durante 10 minutos prolongó por tres días, la vida comercial de la pitahaya amarilla, y redujo cambios en los sólidos solubles y la acidez

  14. 1-MCP pretreatment prevents bud and flower abscission in Dendrobium orchids

    NARCIS (Netherlands)

    Uthaichay, N.; Ketsa, S.; Doorn, van W.G.

    2007-01-01

    Dendrobium orchid inflorescences were treated for 4 h at 25 °C with or without 100¿500 nl/l 1-MCP and were then placed in water at 25 °C to follow abscission. In controls, depending on the experiment, 20¿80% of the floral buds and 0¿20% of the open flowers abscised within 1 week. The 1-MCP

  15. A zerotime detector for nuclear fragments using channel electron multiplier plates

    International Nuclear Information System (INIS)

    Sundqvist, B.

    1975-01-01

    The literature on zerotime detectors which use the emission of secondary electrons from a thin foil is reviewed. The construction of a zerotime detector using multiplication of the secondary electrons with two Mullard channel electron multiplier plates (CEMP) in tandem is described. Results of tests of such a detector with α particles from a natural α source are given. Total time resolutions of about 200 ps (FWHM) with a Si(Sb) detector as the stop detector has been achieved. The contribution from the zerotime detector is estimated to be less than 150 ps (FWHM). The application of this detector technique to the construction of a heavy-ion spectrometer and a 8 Be detector is described. (Auth)

  16. Role of human pulmonary fibroblast-derived MCP-1 in cell activation and migration in experimental silicosis

    International Nuclear Information System (INIS)

    Liu, Xueting; Fang, Shencun; Liu, Haijun; Wang, Xingang; Dai, Xiaoniu; Yin, Qing; Yun, Tianwei; Wang, Wei; Zhang, Yingming; Liao, Hong; Zhang, Wei; Yao, Honghong; Chao, Jie

    2015-01-01

    Background: Silicosis is a systemic disease caused by inhaling silicon dioxide (SiO 2 ). Phagocytosis of SiO 2 in the lung initiates an inflammatory cascade that results in fibroblast proliferation and migration and subsequent fibrosis. Clinical evidence indicates that the activation of alveolar macrophages by SiO 2 produces rapid and sustained inflammation that is characterized by the generation of monocyte chemotactic protein 1 (MCP-1), which induces fibrosis. Pulmonary fibroblast-derived MCP-1 may play a critical role in fibroblast proliferation and migration. Methods and results: Experiments using primary cultured adult human pulmonary fibroblasts (HPF-a) demonstrated the following results: 1) SiO 2 treatment resulted in the rapid and sustained induction of MCP-1 as well as the elevation of the CC chemokine receptor type 2 (CCR2) protein levels; 2) pretreatment of HPF-a with RS-102895, a specific CCR2 inhibitor, abolished the SiO 2 -induced increase in cell activation and migration in both 2D and 3D culture systems; and 3) RNA interference targeting CCR2 prevented the SiO 2 -induced increase in cell migration. Conclusion: These data demonstrated that the up-regulation of pulmonary fibroblast-derived MCP-1 is involved in pulmonary fibroblast migration induced by SiO 2 . CCR2 was also up-regulated in response to SiO 2 , and this up-regulation facilitated the effect of MCP-1 on fibroblasts. Our study deciphered the link between fibroblast-derived MCP-1 and SiO 2 -induced cell migration. This finding provides novel insight into the potential of MCP-1 in the development of novel therapeutic strategies for silicosis. - Highlights: • Role of pulmonary fibroblast-derived MCP-1 in experimental silicosis was studied. • SiO 2 induced MCP-1 release from cultured human pulmonary fibroblast (HPF-a). • SiO 2 directly activated HPF-a via the MCP-1/CCR2 pathway. • SiO 2 increased HPF-a migration in both 2D and 3D model via the MCP-1/CCR2 pathway. • RNA-i of MCP-1/CCR2

  17. Role of human pulmonary fibroblast-derived MCP-1 in cell activation and migration in experimental silicosis

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xueting [Department of Physiology, Medical School of Southeast University, Nanjing, Jiangsu 210009 (China); Fang, Shencun [Nine Department of Respiratory Medicine, Nanjing Chest Hospital, Nanjing, Jiangsu 210029 (China); Liu, Haijun [Neurobiology Laboratory, New Drug Screening Centre, China Pharmaceutical University, Nanjing, Jiangsu 210009 (China); Wang, Xingang; Dai, Xiaoniu; Yin, Qing; Yun, Tianwei [Department of Physiology, Medical School of Southeast University, Nanjing, Jiangsu 210009 (China); Wang, Wei; Zhang, Yingming [Nine Department of Respiratory Medicine, Nanjing Chest Hospital, Nanjing, Jiangsu 210029 (China); Liao, Hong [Neurobiology Laboratory, New Drug Screening Centre, China Pharmaceutical University, Nanjing, Jiangsu 210009 (China); Zhang, Wei [Department of Physiology, Medical School of Southeast University, Nanjing, Jiangsu 210009 (China); Yao, Honghong [Department of Pharmacology, Medical School of Southeast University, Nanjing, Jiangsu 210009 (China); Chao, Jie, E-mail: chaojie@seu.edu.cn [Department of Physiology, Medical School of Southeast University, Nanjing, Jiangsu 210009 (China)

    2015-10-15

    Background: Silicosis is a systemic disease caused by inhaling silicon dioxide (SiO{sub 2}). Phagocytosis of SiO{sub 2} in the lung initiates an inflammatory cascade that results in fibroblast proliferation and migration and subsequent fibrosis. Clinical evidence indicates that the activation of alveolar macrophages by SiO{sub 2} produces rapid and sustained inflammation that is characterized by the generation of monocyte chemotactic protein 1 (MCP-1), which induces fibrosis. Pulmonary fibroblast-derived MCP-1 may play a critical role in fibroblast proliferation and migration. Methods and results: Experiments using primary cultured adult human pulmonary fibroblasts (HPF-a) demonstrated the following results: 1) SiO{sub 2} treatment resulted in the rapid and sustained induction of MCP-1 as well as the elevation of the CC chemokine receptor type 2 (CCR2) protein levels; 2) pretreatment of HPF-a with RS-102895, a specific CCR2 inhibitor, abolished the SiO{sub 2}-induced increase in cell activation and migration in both 2D and 3D culture systems; and 3) RNA interference targeting CCR2 prevented the SiO{sub 2}-induced increase in cell migration. Conclusion: These data demonstrated that the up-regulation of pulmonary fibroblast-derived MCP-1 is involved in pulmonary fibroblast migration induced by SiO{sub 2}. CCR2 was also up-regulated in response to SiO{sub 2}, and this up-regulation facilitated the effect of MCP-1 on fibroblasts. Our study deciphered the link between fibroblast-derived MCP-1 and SiO{sub 2}-induced cell migration. This finding provides novel insight into the potential of MCP-1 in the development of novel therapeutic strategies for silicosis. - Highlights: • Role of pulmonary fibroblast-derived MCP-1 in experimental silicosis was studied. • SiO{sub 2} induced MCP-1 release from cultured human pulmonary fibroblast (HPF-a). • SiO{sub 2} directly activated HPF-a via the MCP-1/CCR2 pathway. • SiO{sub 2} increased HPF-a migration in both 2D and 3D

  18. The chemokine MCP-1 (CCL2) in the host interaction with cancer: a foe or ally?

    Science.gov (United States)

    Yoshimura, Teizo

    2018-01-29

    Macrophages are one of the most abundant leukocyte populations infiltrating tumor tissues and can exhibit both tumoricidal and tumor-promoting activities. In 1989, we reported the purification of monocyte chemoattractant protein-1 (MCP-1) from culture supernatants of mitogen-activated peripheral blood mononuclear cells and tumor cells. MCP-1 is a potent monocyte-attracting chemokine, identical to the previously described lymphocyte-derived chemotactic factor or tumor-derived chemotactic factor, and greatly contributes to the recruitment of blood monocytes into sites of inflammatory responses and tumors. Because in vitro-cultured tumor cells often produce significant amounts of MCP-1, tumor cells are considered to be the main source of MCP-1. However, various non-tumor cells in the tumor stroma also produce MCP-1 in response to stimuli. Studies performed in vitro and in vivo have provided evidence that MCP-1 production in tumors is a consequence of complex interactions between tumor cells and non-tumor cells and that both tumor cells and non-tumor cells contribute to the production of MCP-1. Although MCP-1 production was once considered to be a part of host defense against tumors, it is now believed to regulate the vicious cycle between tumor cells and macrophages that promotes the progression of tumors.Cellular and Molecular Immunology advance online publication, 29 January 2018; doi:10.1038/cmi.2017.135.

  19. Monocyte chemoattractant protein 1 (MCP-1) in temporal arteritis and polymyalgia rheumatica

    DEFF Research Database (Denmark)

    Ellingsen, T; Elling, P; Olson, A

    2000-01-01

    was localised to the vessel wall in patients with TA. In TA, PMR, and healthy controls MCP-1 was quantified by enzyme linked immunosorbent assay (ELISA) in plasma. RESULTS: MCP-1 was localised to the majority of mononuclear cells, some smooth muscle cells, and giant cells in the arterial biopsy specimens from...

  20. Resonant excitation of coupled Rayleigh waves in a short and narrow fluid channel clad between two identical metal plates

    Directory of Open Access Journals (Sweden)

    Victor M. García-Chocano

    2011-12-01

    Full Text Available Transmission of ultrasonic waves through a slit between two water immersed brass plates is studied for sub-wavelength plate thicknesses and slit apertures. Extraordinary high absorption is observed at discrete frequencies corresponding to resonant excitation of Rayleigh waves on the both sides of the channel. The coupling of the Rayleigh waves occurs through the fluid and the corresponding contribution to the dispersion has been theoretically derived and also experimentally confirmed. Symmetric and anti-symmetric modes are predicted but only the symmetric mode resonances have been observed. It follows from the dispersion equation that the coupled Rayleigh waves cannot be excited in a channel with apertures less than the critical one. The calculated critical aperture is in a good agreement with the measured acoustic spectra. These findings could be applied to design a broadband absorptive metamaterial.

  1. Conservação da qualidade de caqui 'Fuyu' em ambiente refrigerado pela combinação de 1-MCP e atmosfera modificada Quality maintenance of 'Fuyu' persimmon in cold storage by combining 1-MCP and modified atmosphere

    Directory of Open Access Journals (Sweden)

    Luiz Carlos Argenta

    2009-06-01

    Full Text Available O presente estudo analisou os efeitos do inibidor da ação do etileno 1-MCP (1-metilciclopropeno, da AM (atmosfera modificada e do oxidante de etileno KMnO4 (permanganato de potássio sobre a qualidade de caqui 'Fuyu' após a armazenagem refrigerada. Os fatores 1-MCP, AM e KMnO4 foram combinados de quatro maneiras, correspondendo aos seguintes tratamentos: T1 Controle + AM + KMnO4;T2 1-MCP + AM + KMnO4; T3 1-MCP + AM, e T4 1-MCP + AA (AA=atmosfera do ar. Frutos maduro-firmes com coloração da casca predominantemente amarela foram colhidos em sete pomares comerciais no nordeste do Estado do Rio Grande do Sul. Parte dos frutos foi exposta a 0.3 µL L-1 de 1-MCP por 12 h em 24 h após a colheita. A seguir, os frutos foram armazenados sob AA ou sob AM induzida por bolsas de polietileno (0,04 mm de espessura, por 20; 40; 60 ou 80 dias a -0,1±0,8ºC. Dois sachês contendo 8,5 g de Alumina-KMnO4foram adicionados em cada uma das bolsas de polietileno dos tratamentos um e dois, antes de elas serem vedadas. Os frutos de cada período de armazenagem refrigerada foram analisados após 0; 3; 6 ou 9 dias de prateleira sob AA a 22±1ºC. O tratamento 1-MCP retardou o amolecimento da polpa, mas não afetou consistentemente o desenvolvimento de 'estrias' e manchas pretas na superfície dos frutos armazenados sob AM contendo KMnO4. A incidência de 'estrias' e manchas pretas em frutos tratados com 1-MCP e armazenados sob AM foi significativamente menor que a de frutos tratados com 1-MCP e armazenados sob AA. Houve efeitos aditivos do 1-MCP e AM na conservação da firmeza e na redução de danos por frio manifestados pela formação de textura gel-firme e manchas translúcidas na casca. O uso de KMnO4 não aumentou a conservação da qualidade dos frutos quando tratados com 1-MCP e armazenados sob AM. O desenvolvimento dos distúrbios da epiderme dependeu do pomar e de períodos de armazenagem e prateleira. No entanto, os benefícios da combinação de 1-MCP e

  2. IP-10, MCP-1, MCP-2, MCP-3, and IL-1RA hold promise as biomarkers for infection with M. tuberculosis in a whole blood based T-cell assay

    DEFF Research Database (Denmark)

    Ruhwald, Morten; Bjerregaard-Andersen, Morten; Rabna, Paulo

    2009-01-01

    and mitogen in the Quantiferon In Tube test tubes. Levels of biomarkers were measured using Luminex and ELISA (IFN-gamma). RESULTS: We found all five new biomarkers were expressed in significantly higher concentrations compared to IFN-gamma. IP-10 and MCP-3 levels in the un-stimulated samples were higher...

  3. MCP/CCR2 signaling is essential for recruitment of mesenchymal progenitor cells during the early phase of fracture healing.

    Directory of Open Access Journals (Sweden)

    Masahiro Ishikawa

    Full Text Available OBJECTIVE: The purpose of this study was to investigate chemokine profiles and their functional roles in the early phase of fracture healing in mouse models. METHODS: The expression profiles of chemokines were examined during fracture healing in wild-type (WT mice using a polymerase chain reaction array and histological staining. The functional effect of monocyte chemotactic protein-1 (MCP-1 on primary mouse bone marrow stromal cells (mBMSCs was evaluated using an in vitro migration assay. MCP-1-/- and C-C chemokine receptor 2 (CCR2-/- mice were fractured and evaluated by histological staining and micro-computed tomography (micro-CT. RS102895, an antagonist of CCR2, was continuously administered in WT mice before or after rib fracture and evaluated by histological staining and micro-CT. Bone graft exchange models were created in WT and MCP-1-/- mice and were evaluated by histological staining and micro-CT. RESULTS: MCP-1 and MCP-3 expression in the early phase of fracture healing were up-regulated, and high levels of MCP-1 and MCP-3 protein expression observed in the periosteum and endosteum in the same period. MCP-1, but not MCP-3, increased migration of mBMSCs in a dose-dependent manner. Fracture healing in MCP-1-/- and CCR2-/- mice was delayed compared with WT mice on day 21. Administration of RS102895 in the early, but not in the late phase, caused delayed fracture healing. Transplantation of WT-derived graft into host MCP-1-/- mice significantly increased new bone formation in the bone graft exchange models. Furthermore, marked induction of MCP-1 expression in the periosteum and endosteum was observed around the WT-derived graft in the host MCP-1-/- mouse. Conversely, transplantation of MCP-1-/- mouse-derived grafts into host WT mice markedly decreased new bone formation. CONCLUSIONS: MCP-1/CCR2 signaling in the periosteum and endosteum is essential for the recruitment of mesenchymal progenitor cells in the early phase of fracture healing.

  4. Time resolution of Burle 85001 micro-channel plate photo-multipliers in comparison with Hamamatsu R2083

    Energy Technology Data Exchange (ETDEWEB)

    V. Baturin; V. Burkert; W. Kim; S. Majewsky; D. Nekrasov; K. Park; V. Popov; E. S. Smith; D. Son; S. S. Stepanyan; C. Zorn

    2005-06-01

    The CLAS detector will require improvements in its particle identification system to take advantage of the higher energies provided by the Jefferson Laboratory accelerator upgrade to 12 GeV. To this end, we have studied the timing characteristics of the micro-channel plate photo-multiplier 85001 from Burle, which can be operated in a high magnetic field environment. For reference and comparison, measurements were also made using the standard PMT R2083 from Hamamatsu using two timing methods. The cosmic ray method, which utilizes three identical scintillating counters 2cm x 3cm x 50cm with PMs at the ends, yields 59.1(0.7)ps. The location method of particles from radiative source with known coordinates has been used to compare timing resolutions of R2083 and Burle-85001. This ''coordinate method'' requires only one counter instrumented with two PMs and it yields 59.5(0.7)ps. For the micro-channel plate photomultiplier from Burle with an external amplification of 10 to the signals, the co ordinate method yields 130(4)ps. This method also makes it possible to estimate the number of primary photo-electrons.

  5. Thermal-hydraulic analysis under partial loss of flow accident hypothesis of a plate-type fuel surrounded by two water channels using RELAP5 code

    OpenAIRE

    Itamar Iliuk; José Manoel Balthazar; Ângelo Marcelo Tusset; José Roberto Castilho Piqueira

    2016-01-01

    Thermal-hydraulic analysis of plate-type fuel has great importance to the establishment of safety criteria, also to the licensing of the future nuclear reactor with the objective of propelling the Brazilian nuclear submarine. In this work, an analysis of a single plate-type fuel surrounding by two water channels was performed using the RELAP5 thermal-hydraulic code. To realize the simulations, a plate-type fuel with the meat of uranium dioxide sandwiched between two Zircaloy-4 plates was prop...

  6. Monte Carlo simulation of irradiation of MTR fuel plates in the BR2 reactor using a full-scale 3-d model with inclined channels

    International Nuclear Information System (INIS)

    Kuzminov, V. V; Koonen, E.; Ponsard, B.

    2002-01-01

    A three-dimensional full-scale Monte Carlo model of the BR2 reactor has been developed for simulation of irradiation conditions of materials and fuel loaded in various irradiation devices. This new reactor model includes a detailed geometrical description of the inclined reactor channels, the irradiation devices loaded in these channels including the materials to be tested/loaded in these devices, the burn-up of the BR2 fuel elements and the poisoning of the beryllium matrix. Recently a benchmark irradiation of new irradiation device for testing and qualification of MTR fuel plates has been performed. For this purpose the detailed irradiation conditions of fuel plates had to be predetermined. Monte Carlo calculations of neutron fluxes and heat load distributions in irradiated MTR fuel plates were performed taking into account the contents of all loaded experimental devices in the reactor channels. A comparison of the calculated and measured values of neutron fluxes and of heat loads in the BR2 reactor is presented in this paper. The comparison is part of the validation process of the new reactor model. It also serves to establish the capability to conduct a fuel plate irradiation program under requested and well- known irradiation conditions. (author)

  7. The role and mechanism of KCa3.1 channels in human monocyte migration induced by palmitic acid.

    Science.gov (United States)

    Ma, Xiao-Zhen; Pang, Zheng-Da; Wang, Jun-Hong; Song, Zheng; Zhao, Li-Mei; Du, Xiao-Jun; Deng, Xiu-Ling

    2018-05-21

    Monocyte migration into diseased tissues contributes to the pathogenesis of diseases. Intermediate-conductance Ca 2+ -activated K + (K Ca 3.1) channels play an important role in cell migration. However, the role of K Ca 3.1 channels in mediating monocyte migration induced by palmitic acid (PA) is still unclear. Using cultured THP-1 cells and peripheral blood mononuclear cells from healthy subjects, we investigated the role and signaling mechanisms of K Ca 3.1 channels in mediating the migration induced by PA. Using methods of Western blotting analysis, RNA interference, cell migration assay and ELISA, we found that PA-treated monocytes exhibited increment of the protein levels of K Ca 3.1 channel and monocyte chemoattractant protein-1 (MCP-1), and the effects were reversed by co-incubation of PA with anti-TLR2/4 antibodies or by specific inhibitors of p38-MAPK, or NF-κB. In addition, PA increased monocyte migration, which was abolished by a specific K Ca 3.1 channel blocker, TRAM-34, or K Ca 3.1 small interfering RNA (siRNA). The expression and secretion of MCP-1 induced by PA was also similarly prevented by TRAM-34 and K Ca 3.1 siRNA. These results demonstrate for the first time that PA upregulates K Ca 3.1 channels through TLR2/4, p38-MAPK and NF-κB pathway to promote the expression of MCP-1, and then induce the trans-endothelial migration of monocytes. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Characteristics of heat transfer and fluid flow in a channel with single-row plates array oblique to flow direction for photovoltaic/thermal system

    International Nuclear Information System (INIS)

    Ali, Ahmed Hamza H.; Ahmed, Mahmoud; Youssef, M.S.

    2010-01-01

    This study has been carried out to investigate the characteristics of convective heat transfer and fluid flow for a single row of oblique plates array to the flow direction inside a channel. The flow inside the channel is laminar and the plates array have spanwise distance between the plates and heated by radiation. This configuration has been designed to be used for Photovoltaic/Thermal system (PV/T) applications. The theoretical results are validated with measured values, and a good agreement prevailed. The results show that an increase in the plate oblique angle (γ) in the range from 0 to 15 degrees, leads to an increase in the Nusselt number (Nu) up to a maximum value and then decreases. The oblique angle at the maximum value of Nu depends on the flow Reynolds Number (Re), and (l w /l pl ), where (l w /l pl ) is defined as the ratio of the plates' spacing at zero oblique angle to the plate length. Furthermore, increasing (l w /l pl ) results in a significant increase in the heat transfer coefficient depending on the values of Re, and plate oblique angle (γ). In addition, increasing (γ) from 0 to 15 degrees results in a decrease in the friction factor up to a certain value, after which the friction value approaches a constant value depending on Re value and (l w /l pl ). It was found that for any value of the plate oblique angle (γ), the friction factor decreases with the increase of the values of (l w /l pl ) and Re, respectively.

  9. A mechanistic modelling approach to understand 1-MCP inhibition of ethylene action and quality changes during ripening of apples.

    Science.gov (United States)

    Gwanpua, Sunny George; Verlinden, Bert E; Hertog, Maarten Latm; Nicolai, Bart M; Geeraerd, Annemie H

    2017-08-01

    1-Methylcyclopropene (1-MCP) inhibits ripening in climacteric fruit by blocking ethylene receptors, preventing ethylene from binding and eliciting its action. The objective of the current study was to use mathematical models to describe 1-MCP inhibition of apple fruit ripening, and to provide a tool for predicting ethylene production, and two important quality indicators of apple fruit, firmness and background colour. A model consisting of coupled differential equations describing 1-MCP inhibition of apple ripening was developed. Data on ethylene production, expression of ethylene receptors, firmness, and background colour during ripening of untreated and 1-MCP treated apples were used to calibrate the model. An overall adjusted R 2 of 95% was obtained. The impact of time from harvest to treatment, and harvest maturity on 1-MCP efficacy was modelled. Different hypotheses on the partial response of 'Jonagold' apple to 1-MCP treatment were tested using the model. The model was validated using an independent dataset. Low 1-MCP blocking efficacy was shown to be the most likely cause of partial response for delayed 1-MCP treatment, and 1-MCP treatment of late-picked apples. Time from harvest to treatment was a more important factor than maturity for 1-MCP efficacy in 'Jonagold' apples. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  10. Analogue saturation limit of single and double 10 mm microchannel plate photomultiplier tubes

    Energy Technology Data Exchange (ETDEWEB)

    Milnes, J. S., E-mail: james.milnes@photek.co.uk; Conneely, T. M. [Photek Ltd., 26 Castleham Road, St Leonards on Sea, East Sussex TN38 9NS (United Kingdom); Horsfield, C. J. [AWE Aldermaston, Reading, Berkshire RG7 4PR (United Kingdom)

    2016-11-15

    Photek are a well-established supplier of microchannel plate (MCP) photomultiplier tubes (PMTs) to the inertial confinement fusion community. The analogue signals produced at the major inertial confinement fusion facilities cover many orders of magnitude, therefore understanding the upper saturation limit of MCP-PMTs to large low rate signals takes on a high importance. Here we present a study of a single and a double MCP-PMT with 10 mm diameter active area. The saturation was studied for a range of optical pulse widths from 4 ns to 100 ns and at a range of electron gain values: 10{sup 3} to 10{sup 4} for the single and 10{sup 4} to 10{sup 6} for the double. We have shown that the saturation level of ∼1.2 nC depends only on the integrated charge of the pulse and is independent of pulse width and gain over this range, but that the level of charge available in deep saturation is proportional to the operating gain.

  11. An efficient and cost-effective microchannel plate detector for slow neutron radiography

    Science.gov (United States)

    Wiggins, B. B.; Vadas, J.; Bancroft, D.; deSouza, Z. O.; Huston, J.; Hudan, S.; Baxter, D. V.; deSouza, R. T.

    2018-05-01

    A novel approach for efficiently imaging objects with slow neutrons in two dimensions is realized. Neutron sensitivity is achieved by use of a boron doped microchannel plate (MCP). The resulting electron avalanche is further amplified with a Z-stack MCP before being sensed by two orthogonally oriented wire planes. Coupling of the wire planes to delay lines efficiently encodes the position information as a time difference. To determine the position resolution, slow neutrons were used to illuminate a Cd-mask placed directly in front of the detector. Peaks in the resulting spectrum exhibited an average peak width of 329 μm FWHM, corresponding to an average intrinsic resolution of 216 μm. The center region of the detector exhibits a significantly better spatial resolution with an intrinsic resolution of <100 μm observed.

  12. Characterizations of MCP performance in the hard x-ray range (6–25 keV)

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Ming, E-mail: minwu@sandia.gov; Rochau, Greg [Sandia National Laboratory, Albuquerque, New Mexico 87185 (United States); Moy, Ken [Special Technology Laboratories, NSTec, Santa Barbara, California 93111-2335 (United States); Kruschwitz, Craig [National Security Technologies, LLC, Los Alamos Operations, Los Alamos, New Mexico 87544 (United States)

    2014-11-15

    MCP detector performance at hard x-ray energies from 6 to 25 keV was recently investigated using NSLS beamline X15A at BNL. Measurements were made with an NSTec Gen-II (H-CA-65) framing camera, based on a Photonis MCP with ∼10 μm in diameter pores, ∼12 μm center-center spacing, an L/D ratio of 46, and a bias angle of 8°. The MCP characterizations were focused on (1) energy and angle dependent sensitivity, (2) energy and angle dependent spatial resolution, (3) energy dependent gain performance, and (4) energy dependent dynamic range. These measurement corroborated simulation results using a Monte Carlo model that included hard x-ray interactions and the subsequent electron cascade in the MCP.

  13. Large-amplitude and narrow-band vibration phenomenon of a foursquare fix-supported flexible plate in a rigid narrow channel

    Energy Technology Data Exchange (ETDEWEB)

    Liu Lifang, E-mail: liu_lifang1106@yahoo.cn [School of Nuclear Science and Engineering, North China Electric Power University, Zhuxinzhuang, Dewai, Beijing 102206 (China); Lu Daogang, E-mail: ludaogang@ncepu.edu.cn [School of Nuclear Science and Engineering, North China Electric Power University, Zhuxinzhuang, Dewai, Beijing 102206 (China); Li Yang, E-mail: qinxiuyi@sina.com [School of Nuclear Science and Engineering, North China Electric Power University, Zhuxinzhuang, Dewai, Beijing 102206 (China); Zhang Pan, E-mail: zhangpan@ncepu.edu.cn [School of Nuclear Science and Engineering, North China Electric Power University, Zhuxinzhuang, Dewai, Beijing 102206 (China); Niu Fenglei, E-mail: niufenglei@ncepu.edu.cn [School of Nuclear Science and Engineering, North China Electric Power University, Zhuxinzhuang, Dewai, Beijing 102206 (China)

    2011-08-15

    Highlights: > FIV of a foursquare fix-supported flexible plate exposed to axial flow was studied. > Special designed test section and advanced measuring equipments were adopted. > The narrow-band vibration phenomenon with large amplitude was observed. > Line of plate's vibration amplitude and flow rate was investigated. > The phenomenon and the measurement error were analyzed. - Abstract: An experiment was performed to analyze the flow-induced vibration behavior of a foursquare fix-supported flexible plate exposed to the axial flow within a rigid narrow channel. The large-amplitude and narrow-band vibration phenomenon was observed in the experiment when the flow velocity varied with the range of 0-5 m/s. The occurring condition and some characteristics of the large-amplitude and narrow-band vibrations were investigated.

  14. Simplified CFD model of coolant channels typical of a plate-type fuel element: an exhaustive verification of the simulations

    Energy Technology Data Exchange (ETDEWEB)

    Mantecón, Javier González; Mattar Neto, Miguel, E-mail: javier.mantecon@ipen.br, E-mail: mmattar@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    The use of parallel plate-type fuel assemblies is common in nuclear research reactors. One of the main problems of this fuel element configuration is the hydraulic instability of the plates caused by the high flow velocities. The current work is focused on the hydrodynamic characterization of coolant channels typical of a flat-plate fuel element, using a numerical model developed with the commercial code ANSYS CFX. Numerical results are compared to accurate analytical solutions, considering two turbulence models and three different fluid meshes. For this study, the results demonstrated that the most suitable turbulence model is the k-ε model. The discretization error is estimated using the Grid Convergence Index method. Despite its simplicity, this model generates precise flow predictions. (author)

  15. Simplified CFD model of coolant channels typical of a plate-type fuel element: an exhaustive verification of the simulations

    International Nuclear Information System (INIS)

    Mantecón, Javier González; Mattar Neto, Miguel

    2017-01-01

    The use of parallel plate-type fuel assemblies is common in nuclear research reactors. One of the main problems of this fuel element configuration is the hydraulic instability of the plates caused by the high flow velocities. The current work is focused on the hydrodynamic characterization of coolant channels typical of a flat-plate fuel element, using a numerical model developed with the commercial code ANSYS CFX. Numerical results are compared to accurate analytical solutions, considering two turbulence models and three different fluid meshes. For this study, the results demonstrated that the most suitable turbulence model is the k-ε model. The discretization error is estimated using the Grid Convergence Index method. Despite its simplicity, this model generates precise flow predictions. (author)

  16. Analysis of hydraulic instability of ANS involute fuel plates

    International Nuclear Information System (INIS)

    Sartory, W.K.

    1991-11-01

    Curved shell equations for the involute Advanced Neutron Source (ANS) fuel plates are coupled to two-dimensional hydraulic channel flow equations that include fluid friction. A complete set of fluid and plate boundary conditions is applied at the entrance and exit and along the sides of the plate and the channel. The coupled system is linearized and solved to assess the hydraulic instability of the plates

  17. Effusion plate using additive manufacturing methods

    Science.gov (United States)

    Johnson, Thomas Edward; Keener, Christopher Paul; Ostebee, Heath Michael; Wegerif, Daniel Gerritt

    2016-04-12

    Additive manufacturing techniques may be utilized to construct effusion plates. Such additive manufacturing techniques may include defining a configuration for an effusion plate having one or more internal cooling channels. The manufacturing techniques may further include depositing a powder into a chamber, applying an energy source to the deposited powder, and consolidating the powder into a cross-sectional shape corresponding to the defined configuration. Such methods may be implemented to construct an effusion plate having one or more channels with a curved cross-sectional geometry.

  18. IL-8 and MCP Gene Expression and Production by LPS-Stimulated Human Corneal Stromal Cells

    Directory of Open Access Journals (Sweden)

    Roni M. Shtein

    2012-01-01

    Full Text Available Purpose. To determine time course of effect of lipopolysaccharide (LPS on production of interleukin-8 (IL-8 and monocyte chemotactic protein (MCP by cultured human corneal stromal cells. Methods. Human corneal stromal cells were harvested from donor corneal specimens, and fourth to sixth passaged cells were used. Cell cultures were stimulated with LPS for 2, 4, 8, and 24 hours. Northern blot analysis of IL-8 and MCP gene expression and ELISA for IL-8 and MCP secretion were performed. ELISA results were analyzed for statistical significance using two-tailed Student's t-test. Results. Northern blot analysis demonstrated significantly increased IL-8 and MCP gene expression after 4 and 8 hours of exposure to LPS. ELISA for secreted IL-8 and MCP demonstrated statistically significant increases (P<0.05 after corneal stromal cell stimulation with LPS. Conclusions. This paper suggests that human corneal stromal cells may participate in corneal inflammation by secreting potent leukocyte chemotactic and activating proteins in a time-dependent manner when exposed to LPS.

  19. Ação do 1-metilciclopropeno (1-MCP na vida de prateleira da banana 'maçã' Action of 1-methylcyclopropene (1-MCP on shelf life of 'apple' banana

    Directory of Open Access Journals (Sweden)

    Ana Carla Marques Pinheiro

    2005-04-01

    Full Text Available Objetivou-se avaliar o efeito do 1-metilciclopropeno (1-MCP, em diferentes concentrações, sobre a vida pós-colheita e sob as variáveis associadas aos atributos de qualidade de banana 'Maçã'. Frutos verde-maturos foram submetidos a cinco concentrações de 1-MCP (0; 50; 100; 150 e 200 etaL.L-1, por 12 horas, e foram analisados durante o amadurecimento sob condição ambiente (20±1ºC e 80±5% UR. O tratamento com 50 etaL.L-1 de 1-MCP atrasou o início do amadurecimento das bananas em aproximadamente 8 dias, baseando-se nas primeiras mudanças de coloração da casca, enquanto os tratamentos 100; 150 e 200 etaL.L-1 atrasaram-no em aproximadamente 10 dias. Observou-se, durante o amadurecimento, o amaciamento dos frutos, associado à conversão de amido em açúcares e ao aumento na solubilização péctica e na atividade da pectinametilesterase (PME e poligalacturonase (PG. A aplicação de 50 etaL.L-1de 1-MCP é a mais adequada por promover a extensão da vida de prateleira de bananas 'Maçã', preservando sua qualidade com base nas análises de açúcares solúveis totais, pectinas total e solúvel, firmeza e aparência externa ao final do armazenamento.The objective of this work was to evaluate the influence of the 1-MCP, at different concentrations, on quality and shelf life of 'Apple' banana. Green mature fruits were submitted to five concentrations of 1-MCP (0, 50, 100, 150 and 200 etaL.L-1, for 12 hours and analyzed during the ripening at room temperature (20ºC ± 1 and 80% ± 5 RH . The 1-MCP at 50 etaL.L-1 delayed, in 8 days, the begining of the ripening, based in the first changes of peel color, whereas 100, 150 and 200 etaL.L-1 treatments delayed the begining of the ripening in 10 days, in comparison to the control. The softening of the fruits, associated to the conversion of starch in sugar and the increasing in the pectic solubilization and activity of pectinmethylsterase and polygalacturonase, was observed during the ripening

  20. Impact of MCP-1 and CCR-2 gene polymorphisms on coronary artery disease susceptibility.

    Science.gov (United States)

    Lin, Hsiu-Ling; Ueng, Kwo-Chang; Hsieh, Yih-Shou; Chiang, Whei-Ling; Yang, Shun-Fa; Chu, Shu-Chen

    2012-09-01

    Coronary artery disease (CAD) was the second leading cause of death during the last 3 years in Taiwan. Smooth muscle cells, monocytes/macrophages, and endothelial cells produce monocyte chemoattractant protein-1 (MCP-1) within atherosclerotic plaques following binding to the chemokine receptor-2 (CCR-2). Previous studies have well-documented the association between MCP-1 expression and susceptibility to, or clinicopathological features, of CAD. This study investigated the relationships between MCP-1-2518A/G and CCR-2-V64I genetic polymorphisms and CAD in the Taiwanese population. A total of 608 subjects, including 392 non-CAD controls and 216 patients with CAD, were recruited and subjected to polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) to evaluate the effects of these two polymorphic variants on CAD. Results indicated a significant association between MCP-1 -2548 gene polymorphism and susceptibility to CAD. GG genotypes (OR = 1.629; 95 % CI = 1.003-2.644), or individuals with at least one G allele (OR = 1.511; 95 % CI = 1.006-2.270), had a higher risk of CAD as compared with AA genotypes. Results also revealed that subjects with at least one A allele of the V64I CCR2 gene polymorphism had significantly increased risk of CAD. G allele in MCP-1-2518 might contribute to higher prevalence of atrial fibrillation in CAD patients (OR = 4.254; p CCR-2 64I gene polymorphisms represent important factors in determining susceptibility to CAD, and the contribution of MCP-1-2518G could be through effects on atrial fibrillation in CAD patients.

  1. Finite element analysis of advanced neutron source fuel plates

    International Nuclear Information System (INIS)

    Luttrell, C.R.

    1995-08-01

    The proposed design for the Advanced Neutron Source reactor core consists of closely spaced involute fuel plates. Coolant flows between the plates at high velocities. It is vital that adjacent plates do not come in contact and that the coolant channels between the plates remain open. Several scenarios that could result in problems with the fuel plates are studied. Finite element analyses are performed on fuel plates under pressure from the coolant flowing between the plates at a high velocity, under pressure because of a partial flow blockage in one of the channels, and with different temperature profiles

  2. Circulating MCP-1 level and вˆј2518 gene polymorphism as a ...

    African Journals Online (AJOL)

    Azza M. Hassan

    that plays an important role in the recruitment of monocytes/macrophages into renal tubulointer- stitium. A biallelic A/G polymorphism at position 2518 in the MCP-1 gene was found ..... minurea, but also with UAE in their type 2 diabetic patients. This is explained by the pivotal role played by increased MCP-. 1 production due ...

  3. Manufacturing of a HCLL cooling plate mock up

    International Nuclear Information System (INIS)

    Rigal, E.; Dinechin, G. de; Rampal, G.; Laffont, G.; Cachon, L.

    2007-01-01

    The European DEMO blankets and associated Test Blanket Modules (TBM) are made of a set of components cooled by flowing helium at 80bar pressure. Hot Isostatic Pressing (HIP) is one of the very few processes that allow manufacturing such components exhibiting complex cooling channels. In HIP technology, the parts used to manufacture components with embedded channels are usually machined plates, blocks and tubes. Achievable geometries are limited in shape because it is not always possible to figure the channels by bent tubes. This occurs for example when channels present sharp turns, when the cross section of the channels is rectangular or when the rib between channels is so small that very thin tubes would be required. In these cases, bending is unpractical. The breeder unit cooling plates of the Helium Cooled Lithium Lead (HCLL) blanket have eight 4 x 4.5 mm parallel channels that run following a double U scheme. Turns are sharp and the wall thickness is small (1mm), so the manufacturing process described above cannot be used. An alternative process has been developed which has many advantages. It consists in machining grooves in a base plate, then closing the top of the grooves using thin welded strips, and finally adding a plate by HIP. There is then no need for the use of tubes with associated bending and deformation issues. The final component contains welds, but it must be stressed out that these potentially brittle zones do not connect the channels to the external surface because they are covered by the HIPed plate. Furthermore, the welds are homogenised during the HIP operation and further heat treatments. This paper describes the design of a simplified cooling plate mock up and its fabrication using this so-called weld+HIP process. The thermal fatigue testing of this mock up is presented somewhere else in this conference. (orig.)

  4. Electron cloud observations at the ISIS Proton Synchrotron

    CERN Document Server

    Pertica, A.

    2013-04-22

    The build up of electron clouds inside a particle accelerator vacuum chamber can produce strong transverse and longitudinal beam instabilities which in turn can lead to high levels of beam loss often requiring the accelerator to be run below its design specification. To study the behaviour of electron clouds at the ISIS Proton Synchrotron, a Micro-Channel Plate (MCP) based electron cloud detector has been developed. The detector is based on the Retarding Field Analyser (RFA) design and consists of a retarding grid, which allows energy analysis of the electron signal, and a MCP assembly placed in front of the collector plate. The MCP assembly provides a current gain over the range 300 to 25K, thereby increasing the signal to noise ratio and dynamic range of the measurements. This paper presents the first electron cloud observations at the ISIS Proton Synchrotron. These results are compared against signals from a beam position monitor and a fast beam loss monitor installed at the same location.

  5. Evaluation of RANS and LES models for Natural Convection in High-Aspect-Ratio Parallel Plate Channels

    Science.gov (United States)

    Fradeneck, Austen; Kimber, Mark

    2017-11-01

    The present study evaluates the effectiveness of current RANS and LES models in simulating natural convection in high-aspect ratio parallel plate channels. The geometry under consideration is based on a simplification of the coolant and bypass channels in the very high-temperature gas reactor (VHTR). Two thermal conditions are considered, asymmetric and symmetric wall heating with an applied heat flux to match Rayleigh numbers experienced in the VHTR during a loss of flow accident (LOFA). RANS models are compared to analogous high-fidelity LES simulations. Preliminary results demonstrate the efficacy of the low-Reynolds number k- ɛ formulations and their enhancement to the standard form and Reynolds stress transport model in terms of calculating the turbulence production due to buoyancy and overall mean flow variables.

  6. Characteristics of heat transfer and fluid flow in a channel with single-row plates array oblique to flow direction for photovoltaic/thermal system

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Ahmed Hamza H. [Department of Energy Resources and Environmental Engineering, Egypt-Japan University of Science and Technology (E-JUST), P.O. Box 179, New Borg El-Arab City, Alexandria 21934 (Egypt); Ahmed, Mahmoud; Youssef, M.S. [Department of Mechanical Engineering, Faculty of Engineering, Assiut University, Assiut 71516 (Egypt)

    2010-09-15

    This study has been carried out to investigate the characteristics of convective heat transfer and fluid flow for a single row of oblique plates array to the flow direction inside a channel. The flow inside the channel is laminar and the plates array have spanwise distance between the plates and heated by radiation. This configuration has been designed to be used for Photovoltaic/Thermal system (PV/T) applications. The theoretical results are validated with measured values, and a good agreement prevailed. The results show that an increase in the plate oblique angle ({gamma}) in the range from 0 to 15 degrees, leads to an increase in the Nusselt number (Nu) up to a maximum value and then decreases. The oblique angle at the maximum value of Nu depends on the flow Reynolds Number (Re), and (l{sub w}/l{sub pl}), where (l{sub w}/l{sub pl}) is defined as the ratio of the plates' spacing at zero oblique angle to the plate length. Furthermore, increasing (l{sub w}/l{sub pl}) results in a significant increase in the heat transfer coefficient depending on the values of Re, and plate oblique angle ({gamma}). In addition, increasing ({gamma}) from 0 to 15 degrees results in a decrease in the friction factor up to a certain value, after which the friction value approaches a constant value depending on Re value and (l{sub w}/l{sub pl}). It was found that for any value of the plate oblique angle ({gamma}), the friction factor decreases with the increase of the values of (l{sub w}/l{sub pl}) and Re, respectively. (author)

  7. Investigation of heat transfer and fluid flow in transitional regime inside a channel with staggered plates heated by radiation for PV/T system

    International Nuclear Information System (INIS)

    Ali, Ahmed Hamza H.; Ahmed, Mahmoud; Abdel-Gaied, S.M.

    2013-01-01

    This study investigates experimentally and theoretically the effects of operating and configuration parameters on convection heat transfer process and fluid flow characteristics for air flowing in transitional regimes through parallel plate channels with staggered plates segments heated by radiant heat flux. This configuration is to be utilized in air heater solar collectors and/or in a combined photovoltaic and air heater solar collector systems (PV/T). The operating parameters tested were Reynolds number (Re) values ranging from 2580 to 4650 with a combination of incident radiation heat flux (q inc ) values of 400, 700, and 1000 W/m 2 , respectively. The experimental results show that the local Nusselt number (Nu x ) is not unique function of the axial distance, in addition, a linear relationship between Re and apparent friction factor (f) was observed. Moreover, the model results show that combination of Re values in the laminar flow regime with proper selection of both plate's length and thickness can lead to enhancement in the heat transfer from the plate segments to the air stream. This is due to self-oscillatory flow mixer in wake zone behind each plate segment. Consequently, this will lead to avoid the need of more pumping power for the case of the flow falling within the transitional regime in the channel. - Highlights: • The local heat transfer coefficient is not unique function in the axial distance. • A linear relationship between Reynolds number and apparent friction factor is observed for Re > 3500. • The plate thickness is the dominant parameter affects both values of the heat transfer and friction factor. • Shorter plates' length, at any plate thickness, leads to periodic boundary layers interruption mechanisms

  8. Unsteady MHD blood flow through porous medium in a parallel plate channel

    Science.gov (United States)

    Latha, R.; Rushi Kumar, B.

    2017-11-01

    In this study, we have analyzed heat and mass transfer effects on unsteady blood flow through parallel plate channel in a saturated porous medium in the presence of a transverse magnetic field with thermal radiation. The governing higher order nonlinear PDE’S are converted to dimensionless equations using dimensionless variables. The dimensionless equations are then solved analytically using boundary conditions by choosing the axial flow transport and the fields of concentration and temperature apart from the normal velocity as a function of y and t. The effects of different pertinent parameters appeared in this model viz thermal radiation, Prandtl number, Heat source parameter, Hartmann number, Permeability parameter, Decay parameter on axial flow transport and the normal velocity are analyzed in detail.

  9. Development of noise-suppressed detector for single ion hit system

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Takuro; Hamano, Tsuyoshi; Suda, Tamotsu; Hirao, Toshio; Kamiya, Tomihiro [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    A noise-suppressed detector for single ion detection has been developed, and combined with the heavy ion microbeam apparatus. This detector consists of a pair of micro channel plates (MCP`s) and a very thin carbon foil. The detection signal is formed by the coincidence of the signals from these MCP`s, so that this detector and the coincidence measurement unit can reduce miscounting in the circuit. The detection efficiency for 15 MeV heavy ions was evaluated to be comparable to that of a silicon surface-barrier detector (SSD) and the miscounting rate was 4 orders lower than the noise rate of a single MCP. The rise time of the detection signal was also estimated. (author)

  10. Toward a noncytotoxic glioblastoma therapy: blocking MCP-1 with the MTZ Regimen

    Directory of Open Access Journals (Sweden)

    Salacz ME

    2016-04-01

    Full Text Available Michael E Salacz,1,2 Richard E Kast,3 Najmaldin Saki,4 Ansgar Brüning,5 Georg Karpel-Massler,6 Marc-Eric Halatsch6 1Department of Internal Medicine, 2Department of Neurosurgery, University of Kansas, Kansas City, KS, USA; 3IIAIGC Study Center, Burlington, VT, USA; 4Health Research Institute, Research Center of Thalassemia and Hemoglobinopathy, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran; 5Molecular Biology Laboratory, University Hospital Munich, Munich, Germany; 6Department of Neurosurgery, University of Ulm, Ulm, Germany Abstract: To improve the prognosis of glioblastoma, we developed an adjuvant treatment directed to a neglected aspect of glioblastoma growth, the contribution of nonmalignant monocyte lineage cells (MLCs (monocyte, macrophage, microglia, dendritic cells that infiltrated a main tumor mass. These nonmalignant cells contribute to glioblastoma growth and tumor homeostasis. MLCs comprise of approximately 10%–30% of glioblastoma by volume. After integration into the tumor mass, these become polarized toward an M2 immunosuppressive, pro-angiogenic phenotype that promotes continued tumor growth. Glioblastoma cells initiate and promote this process by synthesizing 13 kDa MCP-1 that attracts circulating monocytes to the tumor. Infiltrating monocytes, after polarizing toward an M2 phenotype, synthesize more MCP-1, forming an amplification loop. Three noncytotoxic drugs, an antibiotic – minocycline, an antihypertensive drug – telmisartan, and a bisphosphonate – zoledronic acid, have ancillary attributes of MCP-1 synthesis inhibition and could be re-purposed, singly or in combination, to inhibit or reverse MLC-mediated immunosuppression, angiogenesis, and other growth-enhancing aspects. Minocycline, telmisartan, and zoledronic acid – the MTZ Regimen – have low-toxicity profiles and could be added to standard radiotherapy and temozolomide. Re-purposing older drugs has advantages of established safety and low

  11. Effect of 1-methylcyclopropene (1- MCP) treatment on antioxidant ...

    African Journals Online (AJOL)

    ajl2

    2013-02-13

    Feb 13, 2013 ... of active oxygen-related metabolism of post-harvest Japanese apricot. The results ... a high content of vitamin C (ascorbic acid) and retarding the decrease ..... components analysis of the nfluence of 1-MCP and salicylic acid.

  12. Quality management of cut carnation 'Tempo' with 1- MCP

    African Journals Online (AJOL)

    STORAGESEVER

    2009-10-19

    Oct 19, 2009 ... carnation 'Tempo' which is an ethylene-sensitive flower, were evaluated. The effects of 1-MCP .... rolling of the petals. Water uptake rate (ml g-1 .... The studies of Chamani (2006) on Rosa 'First red' cut flowers revealed that ...

  13. CHANGES IN MECHANICAL PROPERTIES OF MINIMALLY-PROCESSED YELLOW PITAHAYA TREATED WITH 1-MCP

    Directory of Open Access Journals (Sweden)

    LILIANA SERNA COCK

    2012-01-01

    Full Text Available Se evaluaron las propiedades mecánicas de esfuerzo del límite de fluencia (sL, modulo de deformación (Ed, esfuerzo de ruptura (sF, y deformación de Hencky en la ruptura (eHF de muestras de pitahaya amarilla mínimamente procesada y tratadas con 200 μgL-1 de 1-MCP durante el almacenamiento a 10±1 °C y 85% de humedad relativa. Las muestras fueron sometidas a pruebas de compresión uniaxial hasta la ruptura. Los resultados mostraron que las muestras tratadas con 1-MCP presentaron los mayores valores del esfuerzo del límite de fluencia, modulo de elasticidad y esfuerzo de ruptura. Esto indica que la aplicación del 1-MCP proporciona mayor firmeza a la fruta y puede representar una alternativa para disminuir cambios indeseables de textura durante el almacenamiento.

  14. Flow-induced plastic collapse of stacked fuel plates

    Energy Technology Data Exchange (ETDEWEB)

    Davis, D C; Scarton, H A

    1985-03-01

    Flow-induced plastic collapse of stacked fuel plate assemblies was first noted in experimental reactors such as the ORNL High Flux Reactor Assembly and the Engineering Test Reactor (ETR). The ETR assembly is a stack of 19 thin flat rectangular fuel plates separated by narrow channels through which a coolant flows to remove the heat generated by fission of the fuel within the plates. The uranium alloyed plates have been noted to buckle laterally and plastically collapse at the system design coolant flow rate of 10.7 m/s, thus restricting the coolant flow through adjacent channels. A methodology and criterion are developed for predicting the plastic collapse of ETR fuel plates. The criterion is compared to some experimental results and the Miller critical velocity theory.

  15. 'Diffuse skin browning' in 1-MCP-treated apples: etiology and systems of control.

    Science.gov (United States)

    Larrigaudière, Christian; Vilaplana, Rosa; Recasens, Inmaculada; Soria, Yolanda; Dupille, Eve

    2010-11-01

    'Diffuse skin browning' (DSB) is a physiological disorder that affects Golden Delicious apples treated with 1-methylcyclopropene (1-MCP). Although a very high incidence is found, very little is known about the etiology of this disorder. This study aims to provide an understanding of the causes of this disorder and prevent it. A very high incidence of DSB was found in 1-MCP-treated apples independent of the location of the orchard. Similar to superficial scald, harvest maturity determines the DSB incidence, with the more mature fruit being less sensitive. The 1-MCP dose (156 nL L(-1) or 625 nL L(-1)) and the temperature at which the 1-MCP treatment was applied (0.5 or 20 °C) did not affect the incidence of DSB. Diphenylamine (DPA) treatment did not prevent DSB, contrary to superficial scald. Additionally, controlled atmosphere storage only partially reduced the incidence of DSB, whereas progressive cooling strategies completely inhibited DSB occurrence. A direct correlation was found between the sensitivity of the Golden Delicious clone to russeting and its sensitivity to develop DSB during storage. Our results indicated that DSB and superficial scald are two different disorders involving different oxidative processes. DSB can be prevented by progressive cooling and selection of russeting-resistant clones. 2010 Society of Chemical Industry

  16. The role of MCP-1-CCR2 ligand-receptor axis in chondrocyte degradation and disease progress in knee osteoarthritis

    Directory of Open Access Journals (Sweden)

    Yuan-kun Xu

    Full Text Available BACKGROUND: Osteoarthritis (OA is a common arthritic disease and multifactorial whole-joint disease. Interactions of chemokines and OA is inadequately documented RESULTS: In vivo and in vitro studies were conducted to investigate monocyte chemoattractant protein 1 (MCP-1 and receptor chemokine (C-C motif receptor 2 (CCR2 in chondrocyte degradation and cartilage degeneration. Chondrocytes from 16 OA patients and 6 normal controls were involved in this study. After stimulation of MCP-1, the expression of MCP-1 and CCR2 increased significantly (P < 0.001 and the expression of MMP-13 also increased (P < 0.05. MCP-1 stimulation also induced (or enhanced the apoptosis of OA chondrocytes (P < 0.05. Additionally, the degradation of cartilage matrix markers (metalloproteinase 3 and 13, MMP3 and MMP13 in the culture medium of normal chondrocytes was also assessed. Furthermore, intra-articular injection of MCP-1 in mouse knees induced cartilage degradation and the CCR2 antagonist did not impede cartilage destroy in rats knees of monosodium iodoacetate (MIA model CONCLUSIONS: The results of this study demonstrate that the MCP-1-CCR2 ligand-receptor axis plays a special role in the initiation and progression of OA pathology. Patients with ambiguous etiology can gain some insight from the MCP-1-CCR2 ligand-receptor axis

  17. Thermally developing forced convection and the corresponding thermal stresses in a porous plate channel

    Institute of Scientific and Technical Information of China (English)

    YANG Xiao; LIU Xuemei

    2007-01-01

    Based on the Darcy fluid model, by considering the effects of viscous dissipation due to the interaction between solid skeleton and pore fluid flow and thermal conduction in the direction of the fluid flow, the thermally developing forced convection of the local thermal equili- brium and the corresponding thermal stresses in a semi- infmite saturated porous plate channel are investigated in this paper. The expressions of temperature, local Nusselt number and corresponding thermal stresses are obtained by means of the Fourier series, and the distributions of the same are also shown. Furthermore, influences of the Péclet number (Pe) and Brinkman number (Br) on temperature, Nusselt number (Nu) and thermal stress are revealed numerically.

  18. Feasibility investigations on a novel micro-manufacturing process for fabrication of fuel cell bipolar plates: Internal pressure-assisted embossing of micro-channels with in-die mechanical bonding

    Energy Technology Data Exchange (ETDEWEB)

    Koc, Muammer [NSF I/UCR Center for Precision Forming (CPF), Department of Mechanical Engineering, Virginia Commonwealth University (VCU), Richmond, VA (United States); Mahabunphachai, Sasawat [NSF I/UCR Center for Precision Forming (CPF), Department of Mechanical Engineering, Virginia Commonwealth University (VCU), Richmond, VA (United States); Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI (United States)

    2007-10-25

    In this paper, we present the results of our studies on conceptual design and feasibility experiments towards development of a novel hybrid manufacturing process to fabricate fuel cell bipolar plates that consists of multi-array micro-channels on a large surface area. The premises of this hybrid micro-manufacturing process stem from the use of an internal pressure-assisted embossing process (cold or warm) combined with mechanical bonding of double bipolar plates in a single-die and single-step operation. Such combined use of hydraulic and mechanical forming forces and in-process bonding will (a) enable integrated forming of micro-channels on both surfaces (as anode and cathode flow fields) and at the middle (as cooling channels), (b) reduce the process steps, (c) reduce variation in dimensional tolerances and surface finish, (d) increase the product quality, (e) increase the performance of fuel cell by optimizing flow-field designs and ensuring consistent contact resistance, and (f) reduce the overall stack cost. This paper explains two experimental investigations that were performed to characterize and evaluate the feasibility of the conceptualized manufacturing process. The first investigation involved hydroforming of micro-channels using thin sheet metals of SS304 with a thickness of 51 {mu}m. The width of the channels ranged from 0.46 to 1.33 mm and the height range was between 0.15 and 0.98 mm. Our feasibility experiments resulted in that different aspect ratios of micro-channels could be fabricated using internal pressure in a controllable manner although there is a limit to very sharp channel shapes (i.e., high aspect ratios with narrow channels). The second investigation was on the feasibility of mechanical bonding of thin sheet metal blanks. The effects of different process and material variables on the bond quality were studied. Successful bonding of various metal blanks (Ni201, Al3003, and SS304) was obtained. The experimental results from both

  19. EFECTO DEL 1-METIL-CICLOPROPENO (1-MCP EN LA MADURACIÓN DE BANANO

    Directory of Open Access Journals (Sweden)

    Kattia Chang-Yuen

    2005-01-01

    Full Text Available Se evaluó la eficacia del 1-metil-ciclopropeno (1-MCP en la maduración del banano (Musa sp Cavendish, aplicado después del empaque en fruta para el mercado de EE.UU. y Europa. Se utilizó fruta de 3 diferentes compañías bananeras; la fruta fue expuesta a 0, 20 y 30 nl l-1 de 1-MCP, por 24 h. Posteriormente, fue sometida a simulación de transporte, según el mercado de destino (7 días EE.UU. y 15 días Europa. Finalizada la simulación se indujo el proceso de maduración con etileno. Las evaluaciones se realizaron cada 2 días, e incluyeron análisis de calidad externa (enfermedades poscosecha y desarrollo de color externo de la cáscara y de calidad interna (oBrix, firmeza, porcentaje de acidez titulable y tasa de produc ción de CO2. Una aplicación de 30 nl l-1 de 1-MCP, generó una ganancia de más de 4 días de vida de anaquel por encima de la fruta control.La apariencia externa y la calidad interna de la fruta no se vio afectada de forma negativa por la exposición al 1-MCP, aunque se recomienda realizar pruebas sensoriales con consumidores en los mercados de destino.

  20. Effects of Triptergium Glycosides on Expressions of MCP- 1 and ...

    African Journals Online (AJOL)

    the pathogenesis of diabetic nephropathy (DN), which is one of the chronic ..... the release of lysosomal enzymes and TGF, increase the ... important roles in the pathogenesis of this disease. Thus, MCP-1 and CTGF are potential targets for ...

  1. Ethylene and 1-MCP regulate major volatile biosynthetic pathways in apple fruit.

    Science.gov (United States)

    Yang, Xiaotang; Song, Jun; Du, Lina; Forney, Charles; Campbell-Palmer, Leslie; Fillmore, Sherry; Wismer, Paul; Zhang, Zhaoqi

    2016-03-01

    The effects of ethylene and 1-methylcyclopropene (1-MCP) on apple fruit volatile biosynthesis and gene expression were investigated. Statistical analysis identified 17 genes that changed significantly in response to ethylene and 1-MCP treatments. Genes encoding branched-chain amino acid aminotransferase (BCAT), aromatic amino acid aminotransferase (ArAT) and amino acid decarboxylases (AADC) were up-regulated during ripening and further enhanced by ethylene treatment. Genes related to fatty acid synthesis and metabolism, including acyl-carrier-proteins (ACPs), malonyl-CoA:ACP transacylase (MCAT), acyl-ACP-desaturase (ACPD), lipoxygenase (LOX), hydroperoxide lyase (HPL), alcohol dehydrogenase (ADH), pyruvate decarboxylase (PDC2), β-oxidation, acyl-CoA synthetase (ACS), enoyl-CoA hydratase (ECHD), acyl-CoA dehydrogenase (ACAD), and alcohol acyltransferases (AATs) also increased during ripening and in response to ethylene treatment. Allene oxide synthase (AOS), alcohol dehydrogenase 1 (ADH1), 3-ketoacyl-CoA thiolase and branched-chain amino acid aminotransferase 2 (BCAT2) decreased in ethylene-treated fruit. Treatment with 1-MCP and ethylene generally produced opposite effects on related genes, which provides evidence that regulation of these genes is ethylene dependent. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  2. Quality management of cut carnation 'Tempo' with 1- MCP | Abadi ...

    African Journals Online (AJOL)

    Quality management of cut carnation 'Tempo' with 1- MCP. ... African Journal of Biotechnology ... time durations (3, 6 and 9 h) on the vaselife, water uptake, loss of fresh weight and chlorophyll index of cut carnation 'Tempo' which is an ...

  3. Insulin resistance is associated with MCP1-mediated macrophage accumulation in skeletal muscle in mice and humans.

    Directory of Open Access Journals (Sweden)

    David Patsouris

    Full Text Available Inflammation is now recognized as a major factor contributing to type 2 diabetes (T2D. However, while the mechanisms and consequences associated with white adipose tissue inflammation are well described, very little is known concerning the situation in skeletal muscle. The aim of this study was to investigate, in vitro and in vivo, how skeletal muscle inflammation develops and how in turn it modulates local and systemic insulin sensitivity in different mice models of T2D and in humans, focusing on the role of the chemokine MCP1. Here, we found that skeletal muscle inflammation and macrophage markers are increased and associated with insulin resistance in mice models and humans. In addition, we demonstrated that intra-muscular TNFα expression is exclusively restricted to the population of intramuscular leukocytes and that the chemokine MCP1 was associated with skeletal muscle inflammatory markers in these models. Furthermore, we demonstrated that exposure of C2C12 myotubes to palmitate elevated the production of the chemokine MCP1 and that the muscle-specific overexpression of MCP1 in transgenic mice induced the local recruitment of macrophages and altered local insulin sensitivity. Overall our study demonstrates that skeletal muscle inflammation is clearly increased in the context of T2D in each one of the models we investigated, which is likely consecutive to the lipotoxic environment generated by peripheral insulin resistance, further increasing MCP1 expression in muscle. Consequently, our results suggest that MCP1-mediated skeletal muscle macrophages recruitment plays a role in the etiology of T2D.

  4. Robot Arm with Tendon Connector Plate and Linear Actuator

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Diftler, Myron A. (Inventor); Bridgwater, Lyndon (Inventor); Nguyen, Vienny (Inventor); Millerman, Alexander (Inventor)

    2014-01-01

    A robotic system includes a tendon-driven end effector, a linear actuator, a flexible tendon, and a plate assembly. The linear actuator assembly has a servo motor and a drive mechanism, the latter of which translates linearly with respect to a drive axis of the servo motor in response to output torque from the servo motor. The tendon connects to the end effector and drive mechanism. The plate assembly is disposed between the linear actuator assembly and the tendon-driven end effector and includes first and second plates. The first plate has a first side that defines a boss with a center opening. The second plate defines an accurate through-slot having tendon guide channels. The first plate defines a through passage for the tendon between the center opening and a second side of the first plate. A looped end of the flexible tendon is received within the tendon guide channels.

  5. Conservação pós-colheita de melão Charentais tratado com 1-MCP e armazenado sob refrigeração e atmosfera modificada Postharvest conservation of charentais melons treated with 1-MCP and stored under refrigeration and modified atmosphere

    Directory of Open Access Journals (Sweden)

    Pahlevi A de Souza

    2008-12-01

    Full Text Available Objetivando avaliar a vida útil pós-colheita de melão tipo Charentais (Cucumis melo L. sob refrigeração, tratados com 1-MCP e associado ou não a atmosfera modificada (AM, foram conduzidos dois experimentos em laboratório da Embrapa Agroindústria Tropical, Fortaleza-CE. Os frutos foram provenientes da Agroindústria Nolem Comercial Importadora e Exportadora Ltda, localizada no Agropólo Mossoró Açu-RN. Os frutos foram tratados com 300 e 600 ppb de 1-MCP, em seguida, metade desses frutos foram embalados em filmes plásticos, mantendo-se frutos embalados sem aplicação de 1-MCP nas mesmas condições de armazenamento dos demais. Os melões foram armazenados por 21 dias sendo 14 dias (9±1ºC e 87±5% UR + 7 dias (22±2ºC e 70±5% UR. Em função da aparência externa, a vida útil pós-colheita dos frutos armazenados sob atmosfera modificada, com ou sem tratamento inicial de 1-MCP foi de 21 dias, enquanto que dos frutos tratados inicialmente apenas com 1-MCP foi de 19 dias. A aplicação do 1-MCP proporcionou redução na atividade respiratória e na produção de etileno, e maior retenção da firmeza da polpa, menor perda de massa e melhor aparência externa quando associado a atmosfera modificada. A atmosfera modificada, isoladamente, foi eficiente em reduzir a perda de massa e manter melhor aparência externa.Aiming to evaluate the postharvest shelf life of Charentais melon (Cucumis melo L. stored under refrigeration, the fruits were treated with 1-MCP, associated or not with modified atmosphere (MAP. Two experiments were carried out at the laboratory of Embrapa Agroindústria Tropical in Fortaleza, Brazil, analyzing the chemical and physic quality characteristics. The fruits were obtained at the Agroindústria Nolem Comercial Importadora e Exportadora Ltda, located in Mossoró Açu, Brazil. The fruits were treated with 300 and 600 nL L-1 of 1-MCP, half of those were wrapped in plastic films, which were wrapped without the use of 1

  6. The roles of MCP-1 and protein kinase C delta activation in human eosinophilic leukemia EoL-1 cells.

    Science.gov (United States)

    Lee, Ji-Sook; Yang, Eun Ju; Kim, In Sik

    2009-12-01

    Idiopathic hypereosinophilc syndrome is a disorder associated with clonally eosinophilic proliferation. The importance of FIP1-like-1-platelet-derived growth factor receptor-alpha (FIP1L1-PDGFRA) in the pathogenesis and classification of HES has been recently reported. In this study, we investigated the contribution of monocyte chemoattractant protein-1 (MCP-1)/CCL2 to chemotactic activity and protein kinase C delta (PKC delta in the human eosinophilic leukemia cell line EoL-1. These cells express CCR2 protein among the CC chemokine receptors (CCR1-5). MCP-1 induces strong migration of EoL-1 cells and the chemotaxis signal in response to MCP-1 involves a G(i)/G(o) protein, phospholipase C (PLC), PKC delta, p38 MAPK and NF-kappaB. MCP-1 activates p38 MAPK via G(i)/G(o) protein, PLC and PKC delta cascade. MCP-1 also induces NF-kappaB translocation and the activation is inhibited by PKC delta activation. The increase in the basal expression and activity of PKC delta in EoL-1 cells, compared to normal eosinophils, inhibits apoptosis in EoL-1 cells. Anti-apoptotic mechanism of PKC delta is related to inhibition of caspase 3 and caspase 9, but not to FIP1L1-PDGFRA. PKC delta functions as an anti-apoptotic molecule, and is involved in EoL-1 cell movement stimulated by MCP-1. This study contributes to an understanding of MCP-1 in eosinophil biology and pathogenic mechanism of eosinophilic disorders.

  7. Myocardial production and release of MCP-1 and SDF-1 following myocardial infarction: differences between mice and man

    Directory of Open Access Journals (Sweden)

    Palasubramaniam Dharshan

    2011-09-01

    Full Text Available Abstract Background Stem cell homing to the heart is mediated by the release of chemo-attractant cytokines. Stromal derived factor -1 alpha (SDF-1a and monocyte chemotactic factor 1(MCP-1 are detectable in peripheral blood after myocardial infarction (MI. It remains unknown if they are produced by, and released from, the heart in order to attract stem cells to repair the damaged myocardium. Methods Murine hearts were studied for expression of MCP-1 and SDF-1a at day 3 and day 28 following myocardial infarction to determine whether production is increased following MI. In addition, we studied the coronary artery and coronary sinus (venous blood from patients with normal coronary arteries, stable coronary artery disease (CAD, unstable angina and MI to determine whether these cytokines are released from the heart into the systemic circulation following MI. Results Both MCP-1 and SDF-1a are constitutively produced and released by the heart. MCP-1 mRNA is upregulated following murine experimental MI, but SDF-1a is suppressed. There is less release of SDF-1a into the systemic circulation in patients with all stages of CAD including MI, mimicking the animal model. However MCP-1 release from the human heart following MI is also suppressed, which is the exact opposite of the animal model. Conclusions SDF-1a and MCP-1 release from the human heart are suppressed following MI. In the case of SDF-1a, the animal model appropriately reflects the human situation. However, for MCP-1 the animal model is the exact opposite of the human condition. Human observational studies like this one are paramount in guiding translation from experimental studies to clinical trials.

  8. The association between MCP-1, VEGF polymorphisms and their serum levels in patients with diabetic foot ulcer.

    Science.gov (United States)

    Li, Xiaolei

    2018-06-01

    The purpose of the present study was to investigate distribution of monocyte chemoattractant protein-1 (MCP-1) -2518A/G and vascular endothelial growth factor (VEGF) -634G/C polymorphisms in type 2 diabetes melitus patients (T2DM) presenting diabetic foot ulcer (DFU). Additionally, we evaluated the effects of these 2 polymorphisms on serum levels of MCP-1 and VEGF in the study population.Patients diagnosed with T2DM without or with DFU were recruited in the study. The distribution of MCP-1 -2518A/G and VEGF -634G/C polymorphisms was investigated by polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP). Enzyme-linked immunosorbent assay (ELISA) was applied to detect the protein levels of MCP-1 and VEGF. The comparisons of protein levels in DFU patients were performed by student t test according to their genotypes.The frequencies of GG genotype and G allele of MCP-1 -2518A/G was increased in DFU patients, compared with T2DM patients (odds ratio [OR] = 2.60, 95% confidence interval [CI] = 1.23-5.50, P = .011 and OR = 1.72, 95% CI = 1.18-2.50, P = .005, respectively). Moreover, the increased frequency of GG was significantly associated with up-regulated MCP-1 level in DFU patients (P < .001). Analysis for VEGF -634G/C polymorphisms indicated that the prevalence of CC genotype and C allele of the polymorphisms was decreased in DFU patients, compared with T2DM patients (OR = 0.36, 95% CI = 0.17-0.77, P = .008 and OR = 0.63, 95% CI = 0.43-0.91, P = .015, respectively). DFU patients carrying CC genotype had a higher level of VEGF than those with other genotypes (P = .007).MCP-1 -2518A/G and VEGF -634G/C polymorphisms may involve in occurrence and progress of DFU through regulating transcription activity of the genes.

  9. A novel design for a variable energy positron lifetime spectrometer

    International Nuclear Information System (INIS)

    Chen, D.; Zhang, J.D.; Cheng, C.C.; Beling, C.D.; Fung, S.

    2008-01-01

    We present computer simulations of a new design of a variable energy positron lifetime beam that uses for a start signal the secondary electron emission from a 25-nm thick carbon foil (C-foil) located in front of the sample. A needle of ∼30 μm diameter is positioned on-axis right behind the foil, creating a radial electric field that deflects the secondary electrons radially outward so as to miss the sample and to hit the micro-channel plate (MCP) detector placed down beam. The MCP signal provides the start signal for the positron lifetime spectrometer. A grid can be further introduced between the sample holder and the MCP to yield a cleaner signal by preventing the positrons with large transmitted scattering angle from hitting the MCP. The cylindrical symmetry of this design reduces the experimental complexity and offers good timing resolution. We show that the design is robust against the transmitted energy and angle of the secondary electrons and positrons

  10. Highly conductive composites for fuel cell flow field plates and bipolar plates

    Science.gov (United States)

    Jang, Bor Z; Zhamu, Aruna; Song, Lulu

    2014-10-21

    This invention provides a fuel cell flow field plate or bipolar plate having flow channels on faces of the plate, comprising an electrically conductive polymer composite. The composite is composed of (A) at least 50% by weight of a conductive filler, comprising at least 5% by weight reinforcement fibers, expanded graphite platelets, graphitic nano-fibers, and/or carbon nano-tubes; (B) polymer matrix material at 1 to 49.9% by weight; and (C) a polymer binder at 0.1 to 10% by weight; wherein the sum of the conductive filler weight %, polymer matrix weight % and polymer binder weight % equals 100% and the bulk electrical conductivity of the flow field or bipolar plate is at least 100 S/cm. The invention also provides a continuous process for cost-effective mass production of the conductive composite-based flow field or bipolar plate.

  11. Use of a vibrating plate to enhance natural convection cooling of a discrete heat source in a vertical channel

    Energy Technology Data Exchange (ETDEWEB)

    Florio, L.A.; Harnoy, A. [Department of Mechanical Engineering, New Jersey Institute of Technology, University Heights, Newark, NJ 07102 (United States)

    2007-09-15

    A numerical investigation was conducted into an alternative method of natural convection enhancement by the transverse oscillations of a thin short plate, strategically positioned in close proximity to a rectangular heat source. The heat source is attached to a mounting board in a vertical channel. Two-dimensional laminar flow finite element studies were carried out with the oscillation parameters, the oscillating plate-heat source mean clearance spacing, and the oscillating plate position varied. Significant cooling was found for displacement amplitudes of at least one-third of the mean clearance together with frequencies (Re/{radical}(Gr)) of over 2{pi} with the displacement being more critical to the cooling level. For the parameters investigated, up to a 52% increase in the local heat transfer coefficient relative to standard natural convection was obtained. The results indicate that this method can serve as a feasible, simpler, more energy and space efficient alternative to common methods of cooling for low power dissipating devices operating at conditions just beyond the reach of pure natural convection. (author)

  12. Correlation of MCP-4 and high-sensitivity C-reactive protein as a marker of inflammation in obesity and chronic periodontitis.

    Science.gov (United States)

    Pradeep, A R; Kumari, Minal; Kalra, Nitish; Priyanka, N

    2013-03-01

    Obesity is increasing in prevalence worldwide and has emerged as a strong risk factor for periodontal disease. Conversely, the remote effects of periodontal disease on various systemic diseases have been proposed. The aim of this study is to determine the presence of MCP-4 and high sensitivity C reactive protein (hsCRP) levels in gingival crevicular fluid (GCF) and serum in obese and non-obese subjects with chronic periodontitis and to find a correlation between MCP-4 and hsCRP in GCF and serum. Forty subjects (20 males and 20 females) were selected and divided into four groups (10 subjects in each group), based on clinical parameters: group NOH (non-obese healthy), group OH (obese healthy), Group NOCP (non-obese with chronic periodontitis) and group OCP (obese with chronic periodontitis). The levels of serum and GCF MCP-4 were determined by ELISA and hsCRP levels were determined by immunoturbidimetry method. The mean GCF and serum concentration of MCP-4 was highest for group OCP followed by group NOCP, group OH (in GCF); group OH, group NOCP(in serum) and least in group NOH. The mean hsCRP concentration was highest for group OCP followed by group OH, group NOCP and group NOH. A significant positive correlation was found between serum and GCF MCP-4 and hsCRP levels. GCF MCP-4 concentrations increased in periodontal disease compared to health and correlated positively with the severity of disease indicating it as a novel marker of periodontal disease. The serum concentration of MCP-4 was found to be more in obese group as compared to nonobese group indicating it as a marker of obesity. Furthermore, based on the positive correlation of MCP-4 and hsCRP found in this study, it can be proposed that MCP-4 and hsCRP may be the markers linking chronic inflammation in obesity and periodontal disease. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Fuel assembly and fuel channel box

    International Nuclear Information System (INIS)

    Sakuma, Toraki; Hirakawa, Hiromasa; Ishizaki, Hideaki; Nakajima, Junjiro; Aizawa, Yasuhiro.

    1992-01-01

    A fuel channel box has a square cylindrical shape and, in the transversal cross sectional shape, the wall thickness of a corner portion is greater than that of a central portion of the side wall except for an upper portion thereof. The upper portion of the channel box includes a region to be in contact with an upper lattice plate and a region to attach a channel spacer. Then, the wall thickness of these regions is uniform in the transversal cross section and they have the same wall thickness with that of the corner portion which has the increased wall thickness. With such a constitution, the upper portion of the channel box receives a counter force applied from the upper lattice plate upon occurrence of earthquakes and moderate it to reduce local stresses and deformation. Further, a similar region with increased wall thickness is disposed also to the lower portion of the channel box, thereby enabling to suppress the amount of coolants leaked from a portion between the lower portion and a lower tie plate, and improve the mechanical integrity of the channel box. (I.N.)

  14. Comparative study of main dosimetric characteristics between the GR-200A and MCP-N LiF (Mg, Cu, P) TLD chips

    International Nuclear Information System (INIS)

    Shen Wenxiu; Tang Kaiyong; Wang Shoushan; Cai Gangang; Zhu Hongying; Lu Min

    1999-01-01

    GR-200A and MCP-N are the same kind of LiF(Mg, Cu, P) chip detectors. The main dosimetric characteristics of two LiF (Mg, Cu, P) chip TLDs (GR-200A made in Solid Dosimetric Detector and Method Laboratory, Beijing, and MCP-N made in Poland) are compared, including glow curve structure, TL sensitivity, anti-moisture, reproducibility, background, detection threshold and photosensitivity. Sensitivity of GR-200a is 1.6 times as much as that of MCP-N. The sensitivity of GR-200A is stable after being used for six times, but the sensitivity of MCP-N dropped 2.8%, and its colour turned from white into light brown. The sensitivity and colour of GR-200A did not vary after being stored for 25 days at 98% RH, by comparison the sensitivity of MCP-N dropped 14%, and its colour turned into light brown. It was found that the GR-200A TLD is superior to the MCP-N TLD in above-mentioned characteristics

  15. The human MCP-2 gene (SCYA8): Cloning, sequence analysis, tissue expression, and assignment to the CC chemokine gene contig on chromosome 17q11.2

    Energy Technology Data Exchange (ETDEWEB)

    Van Coillie, E.; Fiten, P.; Van Damme, J.; Opdenakker, G. [Univ. of Leuven (Belgium)] [and others

    1997-03-01

    Monocyte chemotactic proteins (MCPs) form a subfamily of chemokines that recruit leukocytes to sites of inflammation and that may contribute to tumor-associated leukocyte infiltration and to the antiviral state against HIV infection. With the use of degenerate primers that were based on CC chemokine consensus sequences, the known MIP-1{alpha}/LD78{alpha}, MCP-1, and MCP-3 genes and the previously unidentified eotaxin and MCP-2 genes were isolated from a YAC contig from human chromosome 17q11.2. The amplified genomic MCP-2 fragment was used to isolate an MCP-2 cosmid from which the gene sequence was determined. The MCP-2 gene shares with the MCP-1 and MCP-3 genes a conserved intron-exon structure and a coding nucleotide sequence homology of 77%. By Northern blot analysis the 1.0-kb MCP-2 mRNA was predominantly detectable in the small intestine, peripheral blood, heart, placenta, lung, skeletal muscle, ovary, colon, spinal cord, pancreas, and thymus. Transcripts of 1.5 and 2.4 kb were found in the testis, the small intestine, and the colon. The isolation of the MCP-2 gene from the chemokine contig localized it on YAC clones of chromosome 17q11.2, which also contain the eotaxin, MCP-1, MCP-3, and NCC-1/MCP-4 genes. The combination of using degenerate primer PCR and YACs illustrates that novel genes can efficiently be isolated from gene cluster contigs with less redundancy and effort than the isolation of novel ESTs. 42 refs., 5 figs., 2 tabs.

  16. Crystallization and crystallographic analysis of the ligand-binding domain of the Pseudomonas putida chemoreceptor McpS in complex with malate and succinate

    International Nuclear Information System (INIS)

    Gavira, J. A.; Lacal, J.; Ramos, J. L.; García-Ruiz, J. M.; Krell, T.; Pineda-Molina, E.

    2012-01-01

    The crystallization of the ligand-binding domain of the methyl-accepting chemotaxis protein chemoreceptor McpS (McpS-LBD) is reported. Methyl-accepting chemotaxis proteins (MCPs) are transmembrane proteins that sense changes in environmental signals, generating a chemotactic response and regulating other cellular processes. MCPs are composed of two main domains: a ligand-binding domain (LBD) and a cytosolic signalling domain (CSD). Here, the crystallization of the LBD of the chemoreceptor McpS (McpS-LBD) is reported. McpS-LBD is responsible for sensing most of the TCA-cycle intermediates in the soil bacterium Pseudomonas putida KT2440. McpS-LBD was expressed, purified and crystallized in complex with two of its natural ligands (malate and succinate). Crystals were obtained by both the counter-diffusion and the hanging-drop vapour-diffusion techniques after pre-incubation of McpS-LBD with the ligands. The crystals were isomorphous and belonged to space group C2, with two molecules per asymmetric unit. Diffraction data were collected at the ESRF synchrotron X-ray source to resolutions of 1.8 and 1.9 Å for the malate and succinate complexes, respectively

  17. The cross-validated AUC for MCP-logistic regression with high-dimensional data.

    Science.gov (United States)

    Jiang, Dingfeng; Huang, Jian; Zhang, Ying

    2013-10-01

    We propose a cross-validated area under the receiving operator characteristic (ROC) curve (CV-AUC) criterion for tuning parameter selection for penalized methods in sparse, high-dimensional logistic regression models. We use this criterion in combination with the minimax concave penalty (MCP) method for variable selection. The CV-AUC criterion is specifically designed for optimizing the classification performance for binary outcome data. To implement the proposed approach, we derive an efficient coordinate descent algorithm to compute the MCP-logistic regression solution surface. Simulation studies are conducted to evaluate the finite sample performance of the proposed method and its comparison with the existing methods including the Akaike information criterion (AIC), Bayesian information criterion (BIC) or Extended BIC (EBIC). The model selected based on the CV-AUC criterion tends to have a larger predictive AUC and smaller classification error than those with tuning parameters selected using the AIC, BIC or EBIC. We illustrate the application of the MCP-logistic regression with the CV-AUC criterion on three microarray datasets from the studies that attempt to identify genes related to cancers. Our simulation studies and data examples demonstrate that the CV-AUC is an attractive method for tuning parameter selection for penalized methods in high-dimensional logistic regression models.

  18. Qualidade de caqui 'Rama forte' após armazenamento refrigerado, influenciada pelos tratamentos 1-MCP e/ou CO2

    Directory of Open Access Journals (Sweden)

    João Peterson Pereira Gardin

    2012-12-01

    Full Text Available Avaliaram-se os efeitos dos tratamentos com CO2 e 1-MCP (1-metilciclopropeno sobre a adstringência (índice de tanino, firmeza da polpa e distúrbios da epiderme em caqui 'Rama Forte'. Frutos foram tratados com 1-MCP por 24 h, logo após a colheita e/ou com alto CO2 (70% por 24 ou 48 h, um dia após a colheita ou após o armazenamento refrigerado (AR. Os caquis foram armazenados sob atmosfera modificada a 0 ºC, por 45 dias, e a seguir mantidos a 23 ºC, por 9 dias. Frutos-controle (não tratados com 1-MCP nem com CO2 amoleceram em três dias e perderam aproximadamente 50% da adstringência em 6 dias após o AR. A exposição ao CO2 acelerou a redução da adstringência. Esse efeito do CO2 foi menor em frutos tratados com 1-MCP, especialmente quando o CO2 foi aplicado após o AR, por apenas 24 h. O tratamento com 1-MCP inibiu o amolecimento e a redução da adstringência, especialmente nos frutos não tratados com CO2. O amolecimento de frutos tratados com 1-MCP foi maior quando a exposição ao CO2 ocorreu antes do AR. A combinação dos tratamentos com 1-MCP e alto CO2 reduziu a incidência de podridões e manchas translúcidas, mas não alterou o desenvolvimento de pintas pretas ('estrias'. Os resultados indicam que é possível induzir perda da adstringência sem excessiva perda da firmeza da polpa de caquis 'Rama Forte' após o AR pela associação dos tratamentos com 1-MCP logo após a colheita e alto CO2 após o AR.

  19. Modular Engine Noise Component Prediction System (MCP) Program Users' Guide

    Science.gov (United States)

    Golub, Robert A. (Technical Monitor); Herkes, William H.; Reed, David H.

    2004-01-01

    This is a user's manual for Modular Engine Noise Component Prediction System (MCP). This computer code allows the user to predict turbofan engine noise estimates. The program is based on an empirical procedure that has evolved over many years at The Boeing Company. The data used to develop the procedure include both full-scale engine data and small-scale model data, and include testing done by Boeing, by the engine manufacturers, and by NASA. In order to generate a noise estimate, the user specifies the appropriate engine properties (including both geometry and performance parameters), the microphone locations, the atmospheric conditions, and certain data processing options. The version of the program described here allows the user to predict three components: inlet-radiated fan noise, aft-radiated fan noise, and jet noise. MCP predicts one-third octave band noise levels over the frequency range of 50 to 10,000 Hertz. It also calculates overall sound pressure levels and certain subjective noise metrics (e.g., perceived noise levels).

  20. 2Kx2K resolution element photon counting MCP sensor with >200 kHz event rate capability

    CERN Document Server

    Vallerga, J V

    2000-01-01

    Siegmund Scientific undertook a NASA Small Business Innovative Research (SBIR) contract to develop a versatile, high-performance photon (or particle) counting detector combining recent technical advances in all aspects of Microchannel Plate (MCP) detector development in a low cost, commercially viable package that can support a variety of applications. The detector concept consists of a set of MCPs whose output electron pulses are read out with a crossed delay line (XDL) anode and associated high-speed event encoding electronics. The delay line anode allows high-resolution photon event centroiding at very high event rates and can be scaled to large formats (>40 mm) while maintaining good linearity and high temporal stability. The optimal sensitivity wavelength range is determined by the choice of opaque photocathodes. Specific achievements included: spatial resolution of 200 000 events s sup - sup 1; local rates of >100 events s sup - sup 1 per resolution element; event timing of <1 ns; and low background ...

  1. Resposta da aplicação do 1-MCP em frutos de mamoeiro 'Golden' em diferentes estádios de maturação Responses of 1-MCP applications in 'Golden' papaya fruits on differents maturation stages

    Directory of Open Access Journals (Sweden)

    Maximiliano Silva de Souza

    2009-09-01

    Full Text Available O estudo de fatores que influenciam no processo de amadurecimento é fundamental para o planejamento do processo de comercialização, principalmente em frutos com padrão de respiração climatérico e perecível, como é o caso do mamão. Nesse trabalho, avaliou-se o efeito da aplicação do 1-MCP (1-metilciclopropeno sobre o amadurecimento de frutos de mamoeiro nos estádios 0; 1 e 2 de maturação. O 1-MCP diminui a produção de etileno (≈79% e a taxa respiratória (≈45%, principalmente em frutos no estádio 0 de maturação. O uso deste inibidor da ação do etileno retardou a perda de coloração verde da casca dos frutos, principalmente em frutos nos estádios 0 e 1 de maturação. Houve redução na perda de firmeza do fruto e do mesocarpo nos estádios 1 e 2. Entretanto, em frutos no estádio 0 de maturação, a firmeza do mesocarpo manteve-se alta, o que pode comprometer a aceitação destes frutos pelo consumidor. O teor de sólidos solúveis não foi influenciado pela aplicação do 1-MCP. O efeito do 1-MCP na redução da atividade das enzimas PME e PG foi maior em frutos nos estádios 0 e 1 de maturação em comparação a frutos no estádio 2 de maturação. A atividade da PME demonstrou crescente aumento ao longo do período de armazenamento, porém a atividade da PG permaneceu baixa ao longo dos cinco primeiros dias, com aumento posterior. Os resultados mostraram que a PME exerce influência significativa na perda de firmeza da polpa nos primeiros dias, com atuação posterior da PG. O 1-MCP mostrou-se eficiente em retardar o processo de amadurecimento de frutos de mamoeiro, tornando-se mais eficiente quando associado a estádios de maturação iniciais.The study of factors that influence the process of ripening is critical for planning the marketing process, mainly in standard breathing climacteric and perishing fruits, as it is the case of papaya. In this work it was evaluated the effect of the application of 1-MCP (1

  2. Fuel plate stability experiments and analysis for the Advanced Neutron Source

    International Nuclear Information System (INIS)

    Swinson, W.F.; Battiste, R.L.; Luttrell, C.R.; Yahr, G.T.

    1992-01-01

    The planned Advanced Neutron Source (ANS) and several existing reactors use closely spaced arrays of involute shaped fuel-plates which are cooled by water flowing through the channels between the plates. There is concern that at certain coolant flow velocities adjacent plates may deflect and touch, with resulting failure of the plates. Experiments have been conducted at the Oak Ridge National Laboratory to examine this potential phenomenon. Results of the experiments and comparison with analytical predictions are reported in this paper. The tests were conducted using full scale epoxy plate models of the aluminum/uranium silicide ANS involute shaped fuel plates. Use of epoxy plates and model theory allowed lower flow velocities and pressures to explore the potential failure mechanism. Plate deflections and channel pressures as function of the flow velocity are examined. Comparisons with mathematical models are noted. 12 refs

  3. Fuel plate stability experiments and analysis for the Advanced Neutron Source

    International Nuclear Information System (INIS)

    Swinson, W.F.; Battiste, R.L.; Luttrell, C.R.; Yahr, G.T.

    1993-05-01

    The planned reactor for the Advanced Neutron Source (ANS) will use closely spaced arrays of involute-shaped fuel plates that will be cooled by water flowing through the channels between the plates. There is concern that at certain coolant flow velocities, adjacent plates may deflect and touch, with resulting failure of the plates. Experiments have been conducted at the Oak Ridge National Laboratory to examine this potential phenomenon. Results of the experiments and comparison with analytical predictions are reported. The tests were conducted using full-scale epoxy plate models of the aluminum/uranium silicide ANS involute-shaped fuel plates. Use of epoxy plates and model theory allowed lower flow velocities and pressures to explore the potential failure mechanism. Plate deflections and channel pressures as functions of the flow velocity are examined. Comparisons with mathematical models are noted

  4. Influence of 1-MCP treatments on eating quality and consumer preferences of ‘Qinmei’ kiwifruit during shelf life

    Science.gov (United States)

    Consumers and growers in China sometime complain that Kiwifruits treated with an ethylene action inhibitor 1-MCP are difficult to ripen and show poor eating quality. This study addresses the quality parameters affecting consumer preferences and reevaluates the necessity of 1-MCP application for stor...

  5. Temporal cascade of inflammatory cytokines and cell-type populations in monocyte chemotactic protein-1 (MCP-1)-mediated aneurysm healing.

    Science.gov (United States)

    Hoh, Brian L; Fazal, Hanain Z; Hourani, Siham; Li, Mengchen; Lin, Li; Hosaka, Koji

    2018-03-01

    We have previously shown that monocyte chemotactic protein-1 (MCP-1) promotes aneurysm healing. To determine the temporal cascade and durability of aneurysm healing. Murine carotid aneurysms were treated with MCP-1-releasing or poly(lactic-co-glycolic) acid (PLGA)-only coils. Aneurysm healing was assessed by quantitative measurements of intraluminal tissue ingrowth on 5 μm sections by blinded observers. Aneurysm healing occurred in stages characteristic of normal wound healing. The 1st stage (day 3) was characterized by a spike in neutrophils and T cells. The 2nd stage (week 1) was characterized by an influx of macrophages and CD45+ cells significantly greater with MCP-1 than with PLGA (p<0.05). The third stage (week 2-3) was characterized by proliferation of smooth muscle cells and fibroblasts (greater with MCP-1 than with PLGA, p<0.05). The fourth stage (3-6 months) was characterized by leveling off of smooth muscle cells and fibroblasts. M1 macrophages were greater at week 1, whereas M2 macrophages were greater at weeks 2 and 3 with MCP-1 than with PLGA. Interleukin 6 was present early and increased through week 2 (p<0.05 compared with PLGA) then decreased and leveled off through 6 months. Tumour necrosis factor α was present early and remained constant through 6 months. MCP-1 and PLGA treatment had similar rates of tissue ingrowth at early time points, but MCP-1 had a significantly greater tissue ingrowth at week 3 (p<0.05), which persisted for 6 months. The sequential cascade is consistent with an inflammatory model of injury, repair, and remodeling. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. The TORCH time-of-flight detector

    Energy Technology Data Exchange (ETDEWEB)

    Harnew, N., E-mail: Neville.Harnew@physics.ox.ac.uk [University of Oxford, Denys Wilkinson Building, 1 Keble Road, Oxford OX1 3RH (United Kingdom); Brook, N. [University College London, Department of Physics & Astronomy, Gower Street, London WC1E 6BT (United Kingdom); Castillo García, L. [CERN, PH Department, CH-1211 Geneva 23 (Switzerland); Laboratory for High Energy Physics, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne (Switzerland); Cussans, D. [H.H. Wills Physics Laboratory, University of Bristol, Bristol BS8 1TL (United Kingdom); Föhl, K.; Forty, R.; Frei, C. [CERN, PH Department, CH-1211 Geneva 23 (Switzerland); Gao, R. [University of Oxford, Denys Wilkinson Building, 1 Keble Road, Oxford OX1 3RH (United Kingdom); Gys, T.; Piedigrossi, D. [CERN, PH Department, CH-1211 Geneva 23 (Switzerland); Rademacker, J.; Ros Garcia, A.; Dijk, M. van [H.H. Wills Physics Laboratory, University of Bristol, Bristol BS8 1TL (United Kingdom)

    2016-07-11

    The TORCH time-of-flight detector is being developed to provide particle identification between 2 and 10 GeV/c momentum over a flight distance of 10 m. TORCH is designed for large-area coverage, up to 30 m{sup 2}, and has a DIRC-like construction. The goal is to achieve a 15 ps time-of-flight resolution per incident particle by combining arrival times from multiple Cherenkov photons produced within quartz radiator plates of 10 mm thickness. A four-year R&D programme is underway with an industrial partner (Photek, UK) to produce 53×53 mm{sup 2} Micro-Channel Plate (MCP) detectors for the TORCH application. The MCP-PMT will provide a timing accuracy of 40 ps per photon and it will have a lifetime of up to at least 5 Ccm{sup −2} of integrated anode charge by utilizing an Atomic Layer Deposition (ALD) coating. The MCP will be read out using charge division with customised electronics incorporating the NINO chipset. Laboratory results on prototype MCPs are presented. The construction of a prototype TORCH module and its simulated performance are also described.

  7. Tight connection between fission gas discharge channels

    International Nuclear Information System (INIS)

    Jung, W.; Peehs, M.; Rau, P.; Krug, W.; Stechemesser, H.

    1978-01-01

    The invention is concerned with the tight connection between the fission gas discharge channel, leading away from the support plate of a gas-cooled reactor, and the top of the fuel element suspended from this support plate. The closure is designed to be gas-tight for the suspended as well as for the released fuel element. The tight connection has got an annular body resting on the core support plate in the mouth region of the fission gas discharge channel. This body is connected with the fission gas discharge channel in the fuel element top fitting via a gas-tight part and supported by a compression spring. Care is taken for sealing if the fuel element is removal. (RW) [de

  8. Design optimization of electric vehicle battery cooling plates for thermal performance

    Science.gov (United States)

    Jarrett, Anthony; Kim, Il Yong

    The performance of high-energy battery cells utilized in electric vehicles (EVs) is greatly improved by adequate temperature control. An efficient thermal management system is also desirable to avoid diverting excessive power from the primary vehicle functions. In a battery cell stack, cooling can be provided by including cooling plates: thin metal fabrications which include one or more internal channels through which a coolant is pumped. Heat is conducted from the battery cells into the cooling plate, and transported away by the coolant. The operating characteristics of the cooling plate are determined in part by the geometry of the channel; its route, width, length, etc. In this study, a serpentine-channel cooling plate is modeled parametrically and its characteristics assessed using computational fluid dynamics (CFD). Objective functions of pressure drop, average temperature, and temperature uniformity are defined and numerical optimization is carried out by allowing the channel width and position to vary. The optimization results indicate that a single design can satisfy both pressure and average temperature objectives, but at the expense of temperature uniformity.

  9. The detection of hard x-rays (10-140 KeV) by channel plate electron multipliers

    International Nuclear Information System (INIS)

    Bateman, J.E.

    1976-12-01

    Results are presented indicating that hard X-rays in the energy range 10 to 50 keV can be detected with good efficiency (5 to 10%) in channel plate electron multipliers (CPEM). From 50 keV to 140 keV the detection efficiency lies in the range 1 to 2%. A simple physical model is developed which indicates that not only can good detection efficiency be obtained but that very good X-ray imaging is possible. The model predicts that with further development, a wideband, hard X-ray detector can be realised with a detection efficiency in the range 5 to 20% and spatial response better than 10 lp/mm in the energy range 10 to 140 keV. (author)

  10. Fuel cell cooler-humidifier plate

    Science.gov (United States)

    Vitale, Nicholas G.; Jones, Daniel O.

    2000-01-01

    A cooler-humidifier plate for use in a proton exchange membrane (PEM) fuel cell stack assembly is provided. The cooler-humidifier plate combines functions of cooling and humidification within the fuel cell stack assembly, thereby providing a more compact structure, simpler manifolding, and reduced reject heat from the fuel cell. Coolant on the cooler side of the plate removes heat generated within the fuel cell assembly. Heat is also removed by the humidifier side of the plate for use in evaporating the humidification water. On the humidifier side of the plate, evaporating water humidifies reactant gas flowing over a moistened wick. After exiting the humidifier side of the plate, humidified reactant gas provides needed moisture to the proton exchange membranes used in the fuel cell stack assembly. The invention also provides a fuel cell plate that maximizes structural support within the fuel cell by ensuring that the ribs that form the boundaries of channels on one side of the plate have ends at locations that substantially correspond to the locations of ribs on the opposite side of the plate.

  11. Irradiation of novel MTR fuel plates in BR2

    International Nuclear Information System (INIS)

    Verboomen, B.; Aoust, Th.; Beeckmans De Westmeerbeeck, A.; De Raedt, Ch.

    2000-01-01

    Since the end of 1999, novel MTR fuel plates with very high-density meat are being irradiated in BR2. The purpose of the irradiation is to investigate the behaviour of these fuel plates under very severe reactor operation conditions. The novel fuel plates are inserted in two standard six-tube BR2 fuel elements in the locations normally occupied by the standard outer fuel plates. The irradiation in BR2 was prepared by carrying out detailed neutron Monte Carlo calculations of the whole BR2 core containing the two experimental fuel elements for various positions in the reactor and for various azimuthal orientations of the fuel elements. Comparing the thus determined fission density levels and azimuthal profiles in the new MTR fuel plates irradiated in the various channels allowed the experimenters to choose the most appropriate BR2 channel and the most appropriate fuel element orientation. (author)

  12. A 30 ps Timing Resolution for Single Photons with Multi-pixel Burle MCP-PMT

    Energy Technology Data Exchange (ETDEWEB)

    Va' vra, J.; Benitez, J.; Coleman, J.; Leith, D.W.G.S.; Mazaheri, G.; Ratcliff, B.; Schwiening, J.; /SLAC

    2006-07-05

    We have achieved {approx}30 psec single-photoelectron and {approx}12ps for multi-photoelectron timing resolution with a new 64 pixel Burle MCP-PMT with 10 micron microchannel holes. We have also demonstrated that this detector works in a magnetic field of 15kG, and achieved a single-photoelectron timing resolution of better than 60 psec. The study is relevant for a new focusing DIRC RICH detector for particle identification at future Colliders such as the super B-factory or ILC, and for future TOF techniques. This study shows that a highly pixilated MCP-PMT can deliver excellent timing resolution.

  13. EFECTO DEL EMPAQUE Y DEL 1-MCP SOBRE CARACTERÍSTICAS FÍSICAS, QUÍMICAS Y FISIOLÓGICAS DE PITAHAYA AMARILLA EFEITO DA EMBALAGEM E DO 1-MCP SOB AS PROPRIEDADES QUÍMICAS, FÍSICAS E FISIOLÓGICAS DA PITAHAYA AMARELA EFFECT OF PACKAGING AND 1-MCP ON PHYSICAL, CHEMICAL AND PHYSIOLOGICAL CHARACTERISTICS OF PITAHAYA YELLOW

    Directory of Open Access Journals (Sweden)

    LILIANA SERNA C

    2011-12-01

    Full Text Available En pitahaya amarilla entera con grado de madurez 3, se evaluó el efecto del empaque (canastillas plásticas y cajas de cartón tipo exportación y la aplicación de soluciones acuosas de 1-Metilciclopropeno (200 y 400 µgL-1, sobre la pérdida de peso, firmeza, color, sólidos solubles, acidez titulable, tasa respiratoria y tiempo de vida comercial. Se encontró que en los dos empaques, la aplicación de soluciones acuosas de 200 y 400 µgL-1 de 1-Metilciclopropeno (1-MCP disminuyó los cambios en acidez, tasa respiratoria y color, sin embargo, aumentó la pérdida de peso durante el almacenamiento. El tipo de empaque afectó significativamente la pérdida de peso, los sólidos solubles y el color. La aplicación de 200 µgL-1 de 1-MCP generó menor variación en la luminosidad y en la coloración verde-amarilla en la fruta. Concentraciones de 200 y 400 µgL-1 de 1-MCP y el empaque en canastillas plásticas para mercado local permitieron prolongar el tiempo de vida comercial de la pitahaya amarilla 3 días. Los resultados de este estudio confirman además que la pitahaya amarilla es una fruta climatérica.Na pitahaya amarela inteira com grau tres de madures, foi avallado os efeitos da embalagem (cestos de plástico e caixas de papelão tipo exportação e a aplicação de soluções aquosas de 1-metilciclopropeno (200 e 400 µgL-1 sobre a perda de peso, firmeza, cor, teor de sólidos solúveis totais, acidez, taxa de respiração e tempo de vida comercial. Foi observado que nas duas embalagens, a aplicação de soluções aquosas de 200 e 400 µgL-1 de 1-Metilciclopropeno (1-MCP reduziu as variações na acidez, taxa de respiração e cor, no entanto, aumentou a perda de peso durante o armazenamento. 0 tipo da embalagem afetou significativamente a perda de peso, o teor de sólidos solúveis totais, e acor. A aplicação de 200 µgL-1 de 1-MCP gerou menor variação na luminosidade e na cor verde-amarela no fruto. Concentrações de 200 e 400

  14. Postharvest quality of ‘Galaxy’ apples submitted to the treatment with 1-MCP and different cooling times between harvest and cold storage

    Directory of Open Access Journals (Sweden)

    Crizane Hackbarth

    Full Text Available ABSTRACT: In this research it was evaluated if the use of 1-methylcyclopropene (1-MCP, associated to different cooling times between the harvest and storage, replaces the pre-cooling in ‘Galaxy’ apples. Treatments were arranged in a factorial scheme, combining the following factors: application of 1-MCP (with or without and different times between harvest and cooling (24 hours, 96 hours, 144 hours and 192 hours in 2013; and 24 hours, 48 hours, 144 hours and 240 hours in 2014. After four months of cold storage (1.0±0.2°C/92±5% RH - Relative Humidity were evaluated: flesh firmness, texture, titratable acidity (TA, soluble solids (SS and skin color. Apples treated with 1-MCP showed greater flesh firmness, texture and SS, in both years, and more TA and lower incidence of mealy flesh compared to apples not treated with 1-MCP in 2013. The 1-MCP was effective in maintaining the fruit quality, even with the cooling delay of up to 240 hours. Cooling delay of 192 hours and 240 hours in ‘Galaxy’ apples not treated with 1-MCP should be avoided because it reduces the quality of fruits.

  15. Effect of DPA and 1-MCP on chemical compounds related to superficial scald of Granny Smith apples

    Energy Technology Data Exchange (ETDEWEB)

    Moggia, C.; Moya-Leon, M. A.; Pereira, M.; Yuri, J. A.; Lobos, G. A.

    2010-07-01

    Research was carried out to study the mode of action of diphenylamine (DPA) and 1-methylcyclopropene (1-MCP), on control of superficial scald of Granny Smith apples (Malus domestica Borkh.), and its relation with chemical compounds. Fruit was harvested from a commercial orchard in Chile, 182 and 189 days after full bloom and received the following treatments: DPA (2,000 ppm); 1-MCP (1.2 ppm) and control (no treatment). All fruit was stored for 4 or 6 months at 0 degree centigrade. A completely randomized factorial design was used (2 harvest dates by 3 post harvest treatments). Monthly measurements were made on maturity indices, ethylene production rate (EPR), scald related compounds [a-farnesene (AF), conjugated trienes (CT), total anti-oxidants (AO)], and cell membrane stability. Following 4 and 6 months of storage, plus 7 days at 20 degree centigrade, scald was evaluated. After 6 months, DPA-treated fruit, from both harvests, showed similar firmness, EPR and AO, compared to the control. However, AF and CT were lower, and cell membrane stability higher. Conversely, 1-MCP-treated fruit showed a noticeable EPR suppression and AF inhibition, along with higher firmness, lower CT and AO, compared to the control and DPA. Furthermore, cell membrane stability was superior to that of the control and similar to that of the DPA. Treated fruit (DPA and 1-MCP) showed an important reduction in scald compared to the control. The effect of 1-MCP on the investigated compounds and the reduction in scald, confirms that ethylene plays a major role on its development. (Author) 50 refs.

  16. Experimental investigation of critical velocity in a parallel plate research reactor fuel assembly

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Alfredo J.A.; Scuro, Nikolas L.; Andrade, Delvonei A., E-mail: ajcastro@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNE-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    The fuel elements of a MTR (Material Testing Reactor) type nuclear reactor are mostly composed of aluminum coated fuel plates containing the core of uranium silica (U{sub 3}Si{sub 2}) dispersed in an aluminum matrix. These plates have a thickness of the order of millimeters and are much longer in relation to their thickness. They are arranged in parallel in the assembly of the fuel element to form channels between them a few millimeters in thickness, through which there is a flow of the coolant. This configuration, combined with the need for a flow at high flow rates to ensure the cooling of the fuel element in operation, may create problems of mechanical failure of fuel plate due to the vibration induced by the flow in the channels. In the case of critical velocity excessive permanent deflections of the plates can cause blockage of the flow channel in the reactor core and lead to overheating in the plates. For this study an experimental bench capable of high volume flows and a test section that simulates a plate-like fuel element with three cooling channels were developed. The dimensions of the test section were based on the dimensions of the Fuel Element of the Brazilian Multipurpose Reactor (RMB), whose project is being coordinated by the National Commission of Nuclear Energy (CNEN). The experiments performed attained the objective of reaching Miller's critical velocity condition. The critical velocity was reached with 14.5 m/s leading to the consequent plastic deformation of the flow channel plates. (author)

  17. MCP-1/CCR-2-double-deficiency severely impairs the migration of hematogenous inflammatory cells following transient cerebral ischemia in mice.

    Science.gov (United States)

    Schuette-Nuetgen, Katharina; Strecker, Jan-Kolja; Minnerup, Jens; Ringelstein, E Bernd; Schilling, Matthias

    2012-02-01

    Monocyte chemoattractant protein-1 (MCP-1) and its receptor CCR-2 are known to play a major role in inflammatory responses after cerebral ischemia. Mice deficient in either MCP-1 or CCR-2 have been reported to develop smaller infarct sizes and show decreased numbers of infiltrating inflammatory cells. In the present study we used green fluorescent protein (GFP) transgenic mice to investigate the effect of MCP-1/CCR-2-double deficiency on the recruitment of inflammatory cells in a model of both, mild and severe cerebral ischemia. We show that MCP-1/CCR-2-double deficiency virtually entirely abrogates the recruitment of hematogenous macrophages and significantly reduces neutrophil migration to the ischemic brain 4 and 7 days following focal cerebral ischemia. This argues for a predominant role of the MCP-1/CCR-2 axis in chemotaxis of monocytes despite a wide redundancy in the chemokine-receptor-system. Chemokine analysis revealed that even candidates known to be involved in monocyte and neutrophil recruitment like MIP-1α, CXCL-1, C5a, G-CSF and GM-CSF showed a reduced and delayed or even a lack of relevant compensatory response in MCP-1(-/-)/CCR-2(-/-)-mice. Solely, chemokine receptor 5 (CCR-5) increased early in both, but rose above wildtype levels at day 7 in MCP-1(-/-)/CCR-2(-/-)-animals, which might explain the higher number of activated microglial cells compared to control mice. Our study was, however, not powered to investigate infarct volumes. Further studies are needed to clarify whether these mechanisms of inflammatory cell recruitment might be essential for early infarct development and final infarct size and to evaluate potential therapeutic implications. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Design of control system for optical fiber drawing machine driven by double motor

    Science.gov (United States)

    Yu, Yue Chen; Bo, Yu Ming; Wang, Jun

    2018-01-01

    Micro channel Plate (MCP) is a kind of large-area array electron multiplier with high two-dimensional spatial resolution, used as high-performance night vision intensifier. The high precision control of the fiber is the key technology of the micro channel plate manufacturing process, and it was achieved by the control of optical fiber drawing machine driven by dual-motor in this paper. First of all, utilizing STM32 chip, the servo motor drive and control circuit was designed to realize the dual motor synchronization. Secondly, neural network PID control algorithm was designed for controlling the fiber diameter fabricated in high precision; Finally, the hexagonal fiber was manufactured by this system and it shows that multifilament diameter accuracy of the fiber is +/- 1.5μm.

  19. A case-control association study between Obsessive-Compulsive Disorder (OCD and the MCP-1 -2518G/A polymorphism in a Chinese sample Estudo de associação de casos-controle entre Transtorno Obsessivo-Compulsivo (TOC e polimorfismo MCP-1 -2518G/A em uma coorte chinesa

    Directory of Open Access Journals (Sweden)

    Xinhua Zhang

    2012-12-01

    Full Text Available OBJECTIVE: To investigate the association between Obsessive-Compulsive Disorder (OCD and a functional polymorphism of MCP-1 in the Chinese Han population. METHOD: We genotyped and performed a case-control association analysis of the MCP-1 -2518G/A polymorphism in 200 OCD patients and 294 healthy control subjects. RESULTS: There was no significant difference in MCP-1 -2518G/A genotypic and allelic frequencies between OCD cases and controls (x² = 1.123, df = 2, P = 0.57 by genotype; x² = 0.802, df = 1, P = 0.37 by allele. CONCLUSIONS: Our results indicated that MCP-1 -2518G/A may not play a major role in the genetic predisposition of the Chinese Han population to OCD. However, further studies using a larger number of subjects are required to obtain a clear conclusion.OBJETIVO: Investigar a relação entre Transtorno Obsessivo-Compusilvo (TOC e um polimorfismo funcional de MCP-1 na população chinesa de etnia Han. MÉTODOS: Determinamos os genótipos e realizamos uma análise de associações de casos-controle de polimorfismo MCP-1 -2518G/A em 200 indivíduos com TOC e 294 indivíduos saudáveis (controle. RESULTADOS: Não houve diferença significativa no genótipo MCP-1 -2518G/A e nas frequências alélicas entre casos de TOC e controles (x² = 1,123, df = 2, P = 0,57 por genotipo; x² = 0,802, df = 1, P = 0,37 por alelo. CONCLUSÕES: Nossos resultados indicaram que MCP-1 -2518G/A pode não ter grande participação na predisposição genética da etnia Han no que diz respeito ao TOC. Contudo, novos estudos com um maior número de indivíduos são necessários para uma conclusão mais clara.

  20. Qualidade pós-colheita de quivi 'Hayward' tratado com 1-MCP e armazenado sob diferentes atmosferas

    Directory of Open Access Journals (Sweden)

    Marcelo José Vieira

    2012-06-01

    Full Text Available Este trabalho teve por objetivo avaliar o efeito do 1-MCP sobre o amadurecimento e a qualidade pós-colheita de quivi 'Hayward' armazenado sob diferentes atmosferas. Foram conduzidos dois experimentos, com frutos colhidos em pomar comercial localizado em Fraiburgo-SC. No experimento 1, os frutos foram tratados com três doses de 1-MCP (0,0; 0,5 ou 1,0 µL L-1 e armazenados sob atmosfera controlada (AC, contendo 2,0kPa de O2 + 4,5kPa de CO2, a 0ºC ± 0,5ºC, 92 ± 3% UR, e com <40 ηL L-1 de etileno no ambiente, durante 90 e 120 dias, mais sete dias de vida de prateleira a 23ºC. No experimento 2, os frutos foram tratados com 0,0 ou 0,7 µL L-1 de 1-MCP e armazenados sob atmosfera ambiente (AA, contendo 21 kPa de O2 + 0,03 kPa de CO2, a 0 ± 0,5ºC, 90 ± 3% UR, e com 200 a 250 ηL L-1 de etileno no ambiente, durante 30, 60, 90 e 120 dias, mais um e sete dias de vida de prateleira a 23ºC ou AC (contendo 2,0 kPa de O2 + 4,5 kPa de CO2, a 0ºC ± 0,5ºC, 92 ± 3% UR, e com <40 ηL L-1 de etileno no ambiente, durante 60, 90, 120 e 150 dias, mais um e sete dias de vida de prateleira a 23ºC. Os benefícios do tratamento com 1-MCP sobre a conservação da qualidade foram observados tanto para frutos armazenados sob AA quanto sob AC. No experimento 1, não houve diferença entre as doses de 1-MCP de 0,5 e 1,0 µL L-1 sobre o controle do amadurecimento e manutenção da qualidade dos frutos armazenados em AC. No experimento 2, o tratamento com 1-MCP retardou o aumento na taxa de produção de etileno após remoção de câmara fria. A redução da taxa de produção de etileno nos frutos tratados com 1-MCP foi associada ao aumento na conservação da firmeza da polpa sob AC e AA, e redução na incidência de pericarpo translúcido sob AA. O potencial de armazenamento foi aumentado pelo tratamento com 1-MCP em aproximadamente 60 e 30 dias, nos frutos armazenados sob AA e AC, respectivamente.

  1. Flow induced deformation and collapse of a thin rectangular plate with application to the Engineering Test Reactor nuclear fuel elements

    International Nuclear Information System (INIS)

    Davis, C.D.

    1981-01-01

    This work examines a single flat fuel plate bounded by two channels and determines static plate deflections, resultant forces and bending stresses due to pressure differential and hydrodynamic loadings. The classical then reactangular plate equations are used to model the fuel plate. These equations contain as an input the hydrodynamic loading function for modeling the fluid-structural interaction. Two models of the channel flow are developed. One assumes the accelerating potential core flow is laminar with developing two-dimensional laminar boundary layers being formed on the channel walls. The Schlichting entry length solution for developing laminar flow is found to be valid the entire length of the channel. The second model assumes the core flow is fully-developed turbulent the entire length of the channel. Hydrodynamic loading functions are developed for both flow models containing parameters for fluid density, fluid velocity, Reynolds number and channel and plate dimensions. Hence the effects of each parameter can be examined independently. A criterion is developed for predicting ETR fuel plate collapse at high channel flow velocities, 1067 cm/s (420 in/sec) (R/sub e/ = 60,000). The criterion predicts that in order to prevent ETR plate collapse the inlet velocities between channels must not differ by more than 2%

  2. Changes in quality and biochemical parameters in 'Idared' apples during prolonged shelf life and 1-MCP treatment.

    Science.gov (United States)

    Bizjak, Jan; Slatnar, Ana; Stampar, Franci; Veberic, Robert

    2012-12-01

    In this study, changes in quality and various biochemical parameters of 'Idared' apples during prolonged shelf life period after ultra-low oxygen (ULO) storage were investigated. Additionally, the impact of the postharvest application of 1-methylcyclopropene (1-MCP) on different parameters was evaluated. After the harvest, apples were stored in the ULO storage for 6 months and then exposed to room temperature. Fruit firmness, peel color, and changes in sugars, organic acids and phenolics were monitored during the 3 weeks of shelf life. Malic acid, sugars and firmness decreased at room temperature. However, the color of the apples remained unchanged. The level of citric and ascorbic acid remained constant. Levels of phenolics in the peel increased significantly, whereas remained constant in the pulp of apples. 1-MCP treatment resulted in higher amounts of fructose and glucose, malic acid and greater firmness of apples. However, 1-MCP did not influence the phenolic content, ascorbic acid or color. The results obtained indicate that the content of different health-promoting compounds of apples does not change dramatically at room temperature. At the same time these results suggest that 1-MCP could be useful for maintaining certain quality and biochemical parameters and might extend the shelf life of apples.

  3. The velocity measurement by LDV at the simulated plate fuel assembly

    International Nuclear Information System (INIS)

    Tae Sung Ha

    2001-01-01

    For a more accurate safety analysis for McMaster Nuclear Reactor (MNR), local velocity measurements in a mock-up of the 18-plate fuel assembly are conducted over the range of M=2.0kg/s to 5.0kg/s (u=0.59m/s to 1.48m/s). To enable the measurement of the mass flow distribution through the channels by Laser Doppler Velocimeter(LDV), the curved fuel plate assembly is modified to flat fuel plates. The experimental result shows that the velocity profile is fairly symmetric for the 1st channel to the 17th subchannel at its center. The velocity in the peripheral area is slightly decreased while that directly above the circular pipe is correspondingly increased due to the effect of blockage by the exit endfitting. The mass flow rate fraction is fairly well distributed from the 1st to the 9th channels; at the outmost channels (1st and 3rd subchannels) the flow is approximately 95-97% of the average channel flow and at the central channels (4th and 8th subchannels) the flow is about 102-105% of the average channel mass flow rate. It is shown that the measured mass flow distribution is consistent with the results of the numerical calculation except 1st and 17th channels. (author)

  4. Fabricating cooled electronic system with liquid-cooled cold plate and thermal spreader

    Science.gov (United States)

    Chainer, Timothy J.; Graybill, David P.; Iyengar, Madhusudan K.; Kamath, Vinod; Kochuparambil, Bejoy J.; Schmidt, Roger R.; Steinke, Mark E.

    2018-03-27

    Methods are provided for facilitating cooling of an electronic component. The method includes providing a liquid-cooled cold plate and a thermal spreader associated with the cold plate. The cold plate includes multiple coolant-carrying channel sections extending within the cold plate, and a thermal conduction surface with a larger surface area than a surface area of the component to be cooled. The thermal spreader includes one or more heat pipes including multiple heat pipe sections. One or more heat pipe sections are partially aligned to a first region of the cold plate, that is, where aligned to the surface to be cooled, and partially aligned to a second region of the cold plate, which is outside the first region. The one or more heat pipes facilitate distribution of heat from the electronic component to coolant-carrying channel sections of the cold plate located in the second region of the cold plate.

  5. Fabricating cooled electronic system with liquid-cooled cold plate and thermal spreader

    Energy Technology Data Exchange (ETDEWEB)

    Chainer, Timothy J.; Graybill, David P.; Iyengar, Madhusudan K.; Kamath, Vinod; Kochuparambil, Bejoy J.; Schmidt, Roger R.; Steinke, Mark E.

    2018-04-03

    Methods are provided for facilitating cooling of an electronic component. The methods include providing a liquid-cooled cold plate and a thermal spreader associated with the cold plate. The cold plate includes multiple coolant-carrying channel sections extending within the cold plate, and a thermal conduction surface with a larger surface area than a surface area of the component to be cooled. The thermal spreader includes one or more heat pipes including multiple heat pipe sections. One or more heat pipe sections are partially aligned to a first region of the cold plate, that is, where aligned to the surface to be cooled, and partially aligned to a second region of the cold plate, which is outside the first region. The one or more heat pipes facilitate distribution of heat from the electronic component to coolant-carrying channel sections of the cold plate located in the second region of the cold plate.

  6. Enhanced Freshwater Production Using Finned-Plate Air Gap Membrane Distillation (AGMD

    Directory of Open Access Journals (Sweden)

    Perves Bappy Mohammad Jabed

    2017-01-01

    Full Text Available Air Gap membrane distillation (AGMD, a special type of energy efficient membrane distillation process, is a technology for producing freshwater from waste water. Having some benefits over other traditional processes, this method has been able to draw attention of researchers working in the field of freshwater production technologies. In this study, a basic AGMD system with flat coolant plate has been modified using a specially designed channelled coolant plate of portable size to observe its effect over the production rate and performance of the system. Attempt has been made to increase the amount of distillate flux by using the “fin effect” of the channelled coolant plate. A finned plate have been used instead of a flat coolant plate and experiments were conducted to compare the effect. Coolant temperature and feed temperature of the system have been varied from 10°C to 25°C and 40°C to 70°C respectively. Comparing the data, around 50% to 58% distillate enhancement has been observed for channelled coolant plate. Also, it was seen that the enhancement was higher for higher feed temperatures and coolant temperatures. With these findings, a better performing AGMD module has been introduced to mitigate the scarcity of freshwater.

  7. Combined use of serum MCP-1/IL-10 ratio and uterine artery Doppler index significantly improves the prediction of preeclampsia.

    Science.gov (United States)

    Cui, Shihong; Gao, Yanan; Zhang, Linlin; Wang, Yuan; Zhang, Lindong; Liu, Pingping; Liu, Ling; Chen, Juan

    2017-10-01

    Monocyte chemotactic protein-1 (MCP-1, or CCL2) is a member of the chemokine subfamily involved in recruitment of monocytes in inflammatory tissues. IL-10 is a key regulator for maintaining the balance of anti-inflammatory and pro-inflammatory milieu at the feto-maternal interface. Doppler examination has been routinely performed for the monitoring and management of preeclampsia patients. This study evaluates the efficiency of these factors alone, or in combination, for the predication of preeclampsia. The serum levels of MCP-1 and IL-10 in 78 preeclampsia patients and 143 age-matched normal controls were measured. The Doppler ultrasonography was performed and Artery Pulsatility Index (PI) and Resistance Index (RI) were calculated for the same subjects. It was found that while the second-trimester serum MCP-1, IL-10, MCP-1/IL-10 ratio, PI, and RI showed some power in predicting preeclampsia, the combination of MCP-1/IL-10 and PI and RI accomplishes the highest efficiency, achieving an AUC of 0.973 (95% CI, 0.000-1.000, Ppreeclampsia. Future studies using a larger sample can be conducted to construct an algorithm capable of quantitative assessment on the risk of preeclampsia. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Antifungal activity of 1-methylcyclopropene (1-MCP) against anthracnose (Colletotrichum gloeosporioides) in postharvest mango fruit and its possible mechanisms of action.

    Science.gov (United States)

    Xu, Xiangbin; Lei, Huanhuan; Ma, Xiuyan; Lai, Tongfei; Song, Hongmiao; Shi, Xuequn; Li, Jiangkuo

    2017-01-16

    Anthracnose caused by Colletotrichum gloeosporioides is one of the most important postharvest diseases in mango fruit, often causing huge economic losses. In this study, the effect of 1-methylcyclopropene (1-MCP) against anthracnose in postharvest mango fruit and the mechanisms involved were investigated. 1-MCP induced reactive oxygen species (ROS) generation, damaged the mitochondria and destroyed the integrity of plasma membrane of spores of C. gloeosporioides, significantly suppressing spore germination and mycelial growth of C. gloeosporioides. 1-MCP also decreased the decay incidence and lesion expansion of mango fruit caused by C. gloeosporioides. For the first time this study demonstrated that 1-MCP suppressed anthracnose of postharvest mango fruit by directly inhibiting spore germination and mycelial growth of C. gloeosporioides, thus providing a promising strategy for disease control. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Localization of monocyte chemotactic and activating factor (MCAF/MCP-1) in psoriasis

    DEFF Research Database (Denmark)

    Deleuran, M; Buhl, L; Ellingsen, T

    1996-01-01

    in the epidermal pustules in pustular psoriasis. In normals positive staining was observed in all the layers of the epidermis and in a few perivascular cells and blood vessels in the dermis. Where present in normal and diseased skin, eccrine ducts of sweat glands and sebaceous glands stained positive for MCAF......The monocyte chemotactic protein-1 (MCAF) also termed MCP-1, a strong chemotactic factor towards monocytes, is produced by several cell types present in the skin. The in situ presence of MCAF/MCP-1 protein in the skin has, however, not yet been established. Using immunohistochemical techniques we...... have investigated the distribution of MCAF in skin from patients with different types of psoriasis and normal healthy volunteers. We report the novel finding that psoriasis has strong positive immunostaining for MCAF located to all the layers of the epidermis, except the stratum granulosum, in pustular...

  10. Aumento da expressão do MCP-1 coroidal e escleral em modelo experimental de hipercolesterolemia

    Directory of Open Access Journals (Sweden)

    Rogil José de Almeida Torres

    2012-02-01

    Full Text Available OBJETIVO: O objetivo deste trabalho é demonstrar experimentalmente que a dieta rica em colesterol provoca aumento da expressão da MCP-1 na coroide e esclera. MÉTODO: Coelhos New Zealand foram organizados em dois grupos: GN (grupo dieta normal, composto por 8 coelhos (8 olhos, recebeu ração padrão para coelhos, durante 4 semanas; GH (grupo hipercolesterolêmico, composto por 13 coelhos (13 olhos, recebeu dieta rica em colesterol a 1% por 8 semanas. Foi realizada a dosagem sérica de colesterol total, triglicerídeos, HDL colesterol, glicemia de jejum no início do experimento e no momento da eutanásia. Ao final da 8ª semana para o GH e 4ª semana para o GN foi realizada a eutanásia dos animais e os olhos foram submetidos à análise imuno-histoquímica com o anticorpo anti-MCP-1. RESULTADOS: A dieta provocou significativo aumento do colesterol total e triglicerídeos do GH em relação ao GN (p<0,001. Houve significativo aumento da expressão da MCP-1 na coroide e esclera dos animais do GH em relação ao GN (p<0,001. CONCLUSÃO: Este estudo demonstrou que a dieta hipercolesterolêmica em coelhos induz ao aumento da expressão do MCP-1 na coroide e esclera.

  11. Thermally optimum spacing of vertical, natural convection cooled, parallel plates

    Science.gov (United States)

    Bar-Cohen, A.; Rohsenow, W. M.

    Vertical two-dimensional channels formed by parallel plates or fins are a frequently encountered configuration in natural convection cooling in air of electronic equipment. In connection with the complexity of heat dissipation in vertical parallel plate arrays, little theoretical effort is devoted to thermal optimization of the relevant packaging configurations. The present investigation is concerned with the establishment of an analytical structure for analyses of such arrays, giving attention to useful relations for heat distribution patterns. The limiting relations for fully-developed laminar flow, in a symmetric isothermal or isoflux channel as well as in a channel with an insulated wall, are derived by use of a straightforward integral formulation.

  12. Thermal performance of plate-type loop thermosyphon at sub-atmospheric pressures

    International Nuclear Information System (INIS)

    Tsoi, Vadim; Chang, Shyy Woei; Chiang Kuei Feng; Huang, Chuan Chin

    2011-01-01

    This experimental study examines the thermal performance of a newly devised plate-type two-phase loop thermosyphon with cooling applications to electronic boards of telecommunication systems. The evaporation section is configured as the inter-connected multi channels to emulate the bridging boiling mechanism in pulsating thermosyphon. Two thermosyphon plates using water as the coolant with filling ratios (FR) of 0.22 and 0.32 are tested at sub-atmospheric pressures. The vapor-liquid flow images as well as the thermal resistances and effective spreading thermal conductivities are individually measured for each thermosyphon test plate at various heating powers. The high-speed digital images of the vapor-liquid flow structures reveal the characteristic boiling phenomena and the vapor-liquid circulation in the vertical thermosyphon plate, which assist to explore the thermal physics for this type of loop thermosyphon. The bubble agglomeration and pumping action in the inter-connected boiling channels take place at metastable non-equilibrium conditions, leading to the intermittent slug flows with a pulsation character. Such hybrid loop-pulsating thermosyphon permits the vapor-liquid circulation in the horizontal plate. Thermal resistances and spreading thermal conductivities detected from the present thermosyphon plates; the vapor chamber flat plate heat pipe and the copper plate at free and forced convective cooling conditions with both vertical and horizontal orientations are cross-examined. In most telecommunication systems and units, the electrical boards are vertical so that the thermal performance data on the vertical thermosyphon are most relevant to this particular application. - Highlights: → We examine thermal performances of plate-type loop thermosyphon. → Thermal resistances and spreading conductivities are examined. → Bubble agglomeration in inter-connected boiling channels generates intermittent slug flows with pulsations. → Boiling instability

  13. Correlation of serum MCP-1 and VE-cadherin levels with neural function and carotid atherosclerosis in patients with acute cerebral infarction

    Directory of Open Access Journals (Sweden)

    Yan-Bing Xi

    2017-05-01

    Full Text Available Objective: To study the correlation of serum monocyte chemoattractant protein-1 (MCP-1 and vascular endothelial cadherin (VE-cadherin levels with neural function and carotid atherosclerosis in patients with acute cerebral infarction. Methods: A total of 78 patients who were diagnosed with acute cerebral infarction in our hospital between May 2013 and August 2016 were selected as pathological group, and 80 healthy volunteers who received physical examination in our hospital during the same period were selected as control group. Serum was collected to determine the levels of MCP-1, VE-cadherin, nerve injury molecules, inflammatory mediators, proteases and their hydrolysate. Results: Serum MCP-1, VE-cadherin, NGB, NSE, S100β, HMGB-1, sCD40L, YKL-40, visfatin, CatK, MMP9 and ICTP levels of pathological group were significantly higher than those of control group; serum MCP-1 and VE-cadherin levels of pathological group were positively correlated with NGB, NSE, S100β, HMGB-1, sCD40L, YKL-40, visfatin, CatK, MMP9 and ICTP levels. Conclusion: Serum MCP-1 and VE-cadherin levels abnormally increase in patients with acute cerebral infarction, and are closely related to the nerve injury and atherosclerosis process.

  14. Increased Eotaxin and MCP-1 Levels in Serum from Individuals with Periodontitis and in Human Gingival Fibroblasts Exposed to Pro-Inflammatory Cytokines

    Science.gov (United States)

    Sulniute, Rima; Palmqvist, Py; Majster, Mirjam; Holm, Cecilia Koskinen; Zwicker, Stephanie; Clark, Reuben; Önell, Sebastian; Johansson, Ingegerd; Lerner, Ulf H.; Lundberg, Pernilla

    2015-01-01

    Periodontitis is a chronic inflammatory disease of tooth supporting tissues resulting in periodontal tissue destruction, which may ultimately lead to tooth loss. The disease is characterized by continuous leukocyte infiltration, likely mediated by local chemokine production but the pathogenic mechanisms are not fully elucidated. There are no reliable serologic biomarkers for the diagnosis of periodontitis, which is today based solely on the degree of local tissue destruction, and there is no available biological treatment tool. Prompted by the increasing interest in periodontitis and systemic inflammatory mediators we mapped serum cytokine and chemokine levels from periodontitis subjects and healthy controls. We used multivariate partial least squares (PLS) modeling and identified monocyte chemoattractant protein-1 (MCP-1) and eotaxin as clearly associated with periodontitis along with C-reactive protein (CRP), years of smoking and age, whereas the number of remaining teeth was associated with being healthy. Moreover, body mass index correlated significantly with serum MCP-1 and CRP, but not with eotaxin. We detected higher MCP-1 protein levels in inflamed gingival connective tissue compared to healthy but the eotaxin levels were undetectable. Primary human gingival fibroblasts displayed strongly increased expression of MCP-1 and eotaxin mRNA and protein when challenged with tumor necrosis factor-α (TNF-α and interleukin-1β (IL-1β), key mediators of periodontal inflammation. We also demonstrated that the upregulated chemokine expression was dependent on the NF-κΒ pathway. In summary, we identify higher levels of CRP, eotaxin and MCP-1 in serum of periodontitis patients. This, together with our finding that both CRP and MCP-1 correlates with BMI points towards an increased systemic inflammatory load in patients with periodontitis and high BMI. Targeting eotaxin and MCP-1 in periodontitis may result in reduced leukocyte infiltration and inflammation in

  15. Aspergillus antigen induces robust Th2 cytokine production, inflammation, airway hyperreactivity and fibrosis in the absence of MCP-1 or CCR2

    Directory of Open Access Journals (Sweden)

    Charo Israel F

    2004-09-01

    Full Text Available Abstract Background Asthma is characterized by type 2 T-helper cell (Th2 inflammation, goblet cell hyperplasia, airway hyperreactivity, and airway fibrosis. Monocyte chemoattractant protein-1 (MCP-1 or CCL2 and its receptor, CCR2, have been shown to play important roles in the development of Th2 inflammation. CCR2-deficient mice have been found to have altered inflammatory and physiologic responses in some models of experimental allergic asthma, but the role of CCR2 in contributing to inflammation and airway hyperreactivity appears to vary considerably between models. Furthermore, MCP-1-deficient mice have not previously been studied in models of experimental allergic asthma. Methods To test whether MCP-1 and CCR2 are each required for the development of experimental allergic asthma, we applied an Aspergillus antigen-induced model of Th2 cytokine-driven allergic asthma associated with airway fibrosis to mice deficient in either MCP-1 or CCR2. Previous studies with live Aspergillus conidia instilled into the lung revealed that MCP-1 and CCR2 play a role in anti-fungal responses; in contrast, we used a non-viable Aspergillus antigen preparation known to induce a robust eosinophilic inflammatory response. Results We found that wild-type C57BL/6 mice developed eosinophilic airway inflammation, goblet cell hyperplasia, airway hyperreactivity, elevations in serum IgE, and airway fibrosis in response to airway challenge with Aspergillus antigen. Surprisingly, mice deficient in either MCP-1 or CCR2 had responses to Aspergillus antigen similar to those seen in wild-type mice, including production of Th2 cytokines. Conclusion We conclude that robust Th2-mediated lung pathology can occur even in the complete absence of MCP-1 or CCR2.

  16. Manufacturing method of fuel assembly and channel box for the fuel assembly

    International Nuclear Information System (INIS)

    Fujieda, Tadashi; Inagaki, Masatoshi; Takase, Iwao; Nishino, Yoshitaka; Yamashita, Jun-ichi; Yamanaka, Akihiro; Ito, Ken-ichi; Nakajima, Junjiro; Seto, Takehiro.

    1998-01-01

    An MOX fuel assembly to be used for a BWR type reactor comprises a channel box, a great number of fuel rod bundles and a water rod. BP members incorporated with a burnable neutron absorbing poison (BP) are buried in the vicinity of corners of four sides of the channel box in the longitudinal direction. The channel box is formed by fitting the BP members in concaves formed in the longitudinal direction of zircaloy plates, laminating other zircaloy plates and welding the seams. Then, hot rolling, cold rolling and annealing are conducted to form them into a single plate. Integrated two single plates after bending treatment are abutted and welded, and heat-treatment is applied to complete the channel box. With such a constitution, since the BP member is not brought into contact with reactor water directly, crevice corrosion or galvanic corrosion can be prevented. (I.N.)

  17. Concentrações de IL-6, TNF-α e MCP-1 em crianças com excesso de massa corporal

    Directory of Open Access Journals (Sweden)

    Juliano Magalhães Guedes

    2015-08-01

    Full Text Available O objetivo desta revisão sistemática foi verificar a relação das concentrações de IL-6, TNF-α e MCP-1 em crianças com excesso de massa corporal. As bases de dados investigadas PUBMED, SciELO, LILACS e Periódico Capes foram consultadas retrospectivamente para os últimos seis anos (2009 a 2014 utilizando combinações de palavras chaves como inflamação, IL-6, TNF-α, MCP-1 combinadas com crianças e escolares. Foram analisados 21 artigos. Foi encontrado associação entre sobrepeso/obesidade com IL-6, TNF-α e MCP-1 em 73,3% (11/15, 80% (12/15 e 60% (3/5 dos estudos que analisaram tais marcadores, respectivamente. Crianças com excesso de massa corporal possuem concentrações elevadas de IL-6, TNF-α e MCP-1 resultando em inflamação sistêmica crônica e aumentando o risco de desenvolvimento de outras doenças cardiovasculares. 

  18. Pseudogenization of the MCP-2/CCL8 chemokine gene in European rabbit (genus Oryctolagus, but not in species of Cottontail rabbit (Sylvilagus and Hare (Lepus

    Directory of Open Access Journals (Sweden)

    van der Loo Wessel

    2012-08-01

    Full Text Available Abstract Background Recent studies in human have highlighted the importance of the monocyte chemotactic proteins (MCP in leukocyte trafficking and their effects in inflammatory processes, tumor progression, and HIV-1 infection. In European rabbit (Oryctolagus cuniculus one of the prime MCP targets, the chemokine receptor CCR5 underwent a unique structural alteration. Until now, no homologue of MCP-2/CCL8a, MCP-3/CCL7 or MCP-4/CCL13 genes have been reported for this species. This is interesting, because at least the first two genes are expressed in most, if not all, mammals studied, and appear to be implicated in a variety of important chemokine ligand-receptor interactions. By assessing the Rabbit Whole Genome Sequence (WGS data we have searched for orthologs of the mammalian genes of the MCP-Eotaxin cluster. Results We have localized the orthologs of these chemokine genes in the genome of European rabbit and compared them to those of leporid genera which do (i.e. Oryctolagus and Bunolagus or do not share the CCR5 alteration with European rabbit (i.e. Lepus and Sylvilagus. Of the Rabbit orthologs of the CCL8, CCL7, and CCL13 genes only the last two were potentially functional, although showing some structural anomalies at the protein level. The ortholog of MCP-2/CCL8 appeared to be pseudogenized by deleterious nucleotide substitutions affecting exon1 and exon2. By analyzing both genomic and cDNA products, these studies were extended to wild specimens of four genera of the Leporidae family: Oryctolagus, Bunolagus, Lepus, and Sylvilagus. It appeared that the anomalies of the MCP-3/CCL7 and MCP-4/CCL13 proteins are shared among the different species of leporids. In contrast, whereas MCP-2/CCL8 was pseudogenized in every studied specimen of the Oryctolagus - Bunolagus lineage, this gene was intact in species of the Lepus - Sylvilagus lineage, and was, at least in Lepus, correctly transcribed. Conclusion The biological function of a gene was often

  19. Photon counting with small pore microchannel plates

    International Nuclear Information System (INIS)

    Martindale, A.; Lapington, J.S.; Fraser, G.W.

    2007-01-01

    We describe the operation of microchannel plates (MCPs) with 3.2μm diameter channels as photon counting detectors of soft X-rays. Gain and temporal resolution measurements are compared with theoretical scaling laws for channel diameter. A minimum pulse width of 264ps is observed for a two stage multiplier at a total bias voltage of ∼1930V

  20. EFECTO DEL 1-METILCICLOPROPENO (1-MCP Y TRATAMIENTO HIDROTÉRMICO SOBRE LA FISIOLOGÍA Y CALIDAD DEL MANGO 'KEITT'

    Directory of Open Access Journals (Sweden)

    J. A. Osuna-García

    2007-01-01

    Full Text Available El objetivo del presente trabajo fue evaluar el efecto del 1-MCP (0 y 300 nl·litro-1 y diferentes niveles de tratamiento hidrotérmico (0, 52 °C por 5 min y 46 °C por 110 min sobre la fisiología y calidad de mango 'Keitt'. Se analizó velocidad de respiración, pérdida de peso, firmeza, color de pulpa, sólidos solubles totales y porcentaje de frutos enfermos. Se encontró que la efectividad del 1-MCP varió acorde al nivel de tratamiento hidrotérmico. En frutos sin hidrotérmico el 1-MCP disminuyó velocidad de respiración, no influyó en la pérdida de peso, mantuvo cuatro veces más la firmeza y retrasó el cambio de color de pulpa y el aumento de los sólidos solubles. Sin embargo, bajo tratamiento hidrotérmico por 5 min el 1-MCP incrementó velocidad de respiración, no influyó en la pérdida de peso, mantuvo dos veces más la firmeza de pulpa, retrasó el desarrollo del color de pulpa y mantuvo sin cambios los sólidos solubles. La efectividad del 1-MCP sobre firmeza y pérdida de peso fue significativamente afectada por el tratamiento hidrotérmico de 110 min, y no tuvo ningún efecto sobre el control de enfermedades, sin embargo, el tratamiento con agua caliente por 5 min redujo en más de 50 % la presencia de frutos enfermos. El 1-MCP en combinación con el tratamiento hidrotérmico de 5 min alargó en cinco días la vida de anaquel de los frutos y podría ser una alternativa viable en mercados que no requieren tratamiento hidrotérmico cuarentenario para el control de mosca de la fruta.

  1. Controlled atmosphere pO2 alters ripening dynamics of 1-MCP treated ‘d’Anjou’ pear (Pyrus communis L.) fruit

    Science.gov (United States)

    Ripening and development of physiological disorders and decay were assessed in ‘d’Anjou’ pear fruit following 1-methylcyclopropene (1-MCP) treatment and cold storage in air or controlled atmosphere (CA). Fruit were exposed after harvest to 0 or 12.6 µmol•L-1 1-MCP and then stored at 0.5 oC in air o...

  2. High throughput analysis of red wine and grape phenolics-adaptation and validation of methyl cellulose precipitable tannin assay and modified Somers color assay to a rapid 96 well plate format.

    Science.gov (United States)

    Mercurio, Meagan D; Dambergs, Robert G; Herderich, Markus J; Smith, Paul A

    2007-06-13

    The methyl cellulose precipitable (MCP) tannin assay and a modified version of the Somers and Evans color assay were adapted to high-throughput (HTP) analysis. To improve efficiency of the MCP tannin assay, a miniaturized 1 mL format and a HTP format using 96 well plates were developed. The Somers color assay was modified to allow the standardization of pH and ethanol concentrations of wine samples in a simple one-step dilution with a buffer solution, thus removing inconsistencies between wine matrices prior to analysis and allowing for its adaptation to a HTP format. Validation studies showed that all new formats were efficient, and results were reproducible and analogous to the original formats.

  3. Open Channel Natural Convection Heat Transfer on a Vertical Finned Plate

    International Nuclear Information System (INIS)

    Park, Joo Hyun; Heo, Jeong Hwan; Chung, Bum Jin

    2013-01-01

    The natural convection heat transfer of vertical plate fin was investigated experimentally. Heat transfer systems were replaced by mass-transfer systems, based on the analogy concept. The experimental results lie within the predictions of the existing heat transfer correlations of plate-fin for the natural convections. An overlapped thermal boundary layers caused increasing heat transfer, and an overlapped momentum boundary layers caused decreasing heat transfer. As the fin height increases, heat transfer was enhanced due to increased inflow from the open side of the fin spacing. When fin spacing and fin height are large, heat transfer was unaffected by the fin spacing and fin height. Passive cooling by natural convection becomes more and more important for the nuclear systems as the station black out really happened at the Fukushima NPPs. In the RCCS (Reactor Cavity Cooling System) of a VHTR (Very High Temperature Reactor), natural convection cooling through duct system is adopted. In response to the stack failure event, extra cooling capacity adopting the fin array has to be investigated. The finned plate increases the surface area and the heat transfer increases. However, the plate of fin arrays may increase the pressure drop and the heat transfer decreases. Therefore, in order to enhance the passive cooling with fin arrays, the parameters for the fin arrays should be optimized. According to Welling and Wooldridge, a natural convection on vertical plate fin is function of Gr, Pr, L, t, S, and H. The present work investigated the natural convection heat transfer of a vertical finned plate with varying the fin height and the fin spacing. In order achieve high Rayleigh numbers, an electroplating system was employed and the mass transfer rates were measured using a copper sulfate electroplating system based on the analogy concept

  4. Experimental study of fluid flow in the entrance of a sinusoidal channel

    International Nuclear Information System (INIS)

    Oviedo-Tolentino, F.; Romero-Mendez, R.; Hernandez-Guerrero, A.; Giron-Palomares, B.

    2008-01-01

    An experimental flow visualization study of the entrance section of channels formed with sinusoidal plates was made. The experiments were conducted in a water tunnel and a laser illuminated particle tracking was used as the technique of flow visualization. The geometric parameters of the plates were maintained constant while the distance between plates, phase angle, and the Reynolds number were varied during the experiments. The flow regimes that were found in the experiments are steady, unsteady and significantly-mixed flows. Instabilities of the flow first appear near the exit of the channel, and move closer to the inlet waves as the Reynolds number grows, but in the first wave from inlet the flow is always steady. The results show that, for all other parameters fixed, the Reynolds number at which unsteady flow first appears grows with the distance between plates. The phase angle that best promotes unsteady flow depends on the average distance between plates: for certain average distance between plates, there is a phase angle that best disturbs the flow. For the set of parameters used in this experiment, a channel with eight waves is sufficiently long and the flow features presented in the first eight waves of a longer channel will be similar to what was observed here

  5. High thermal load receiving heat plate

    International Nuclear Information System (INIS)

    Shibutani, Jun-ichi; Shibayama, Kazuhito; Yamamoto, Keiichi; Uchida, Takaho.

    1993-01-01

    The present invention concerns a high thermal load heat receiving plate such as a divertor plate of a thermonuclear device. The high thermal load heat receiving plate of the present invention has a cooling performance capable of suppressing the temperature of an armour tile to less than a threshold value of the material against high thermal loads applied from plasmas. Spiral polygonal pipes are inserted in cooling pipes at a portion receiving high thermal loads in the high temperature load heat receiving plate of the present invention. Both ends of the polygonal pipes are sealed by lids. An area of the flow channel in the cooling pipes is thus reduced. Heat conductivity on the cooling surface of the cooling pipes is increased in the high thermal load heat receiving plate having such a structure. Accordingly, temperature elevation of the armour tile can be suppressed. (I.S.)

  6. Use of equimolar cysteine/ascorbic acids to recover MCP synthesized Ti(Mg) alloy

    CSIR Research Space (South Africa)

    Mushove, T

    2010-10-01

    Full Text Available Dissolution of waste by-products of mechanochemical processing (MCP) synthesis of Ti(Mg) alloy, from TiO2 and 15 wt.% excess Mg, was conducted in equimolar cysteine/ascorbic acids. The synthesized alloy is inherently mixed with MgO and other oxides...

  7. Gain uniformity, linearity, saturation and depletion in gated microchannel-plate x-ray framing cameras

    International Nuclear Information System (INIS)

    Landen, O.L.; Bell, P.M.; Satariano, J.J.; Oertel, J.A.; Bradley, D.K.

    1994-01-01

    The pulsed characteristics of gated, stripline configuration microchannel-plate (MCP) detectors used in X-ray framing cameras deployed on laser plasma experiments worldwide are examined in greater detail. The detectors are calibrated using short (20 ps) and long (500 ps) pulse X-ray irradiation and 3--60 ps, deep UV (202 and 213 nm), spatially-smoothed laser irradiation. Two-dimensional unsaturated gain profiles show 5 in irradiation and fitted using a discrete dynode model. Finally, a pump-probe experiment quantifying for the first time long-suspected gain depletion by strong localized irradiation was performed. The mechanism for the extra voltage and hence gain degradation is shown to be associated with intense MCP irradiation in the presence of the voltage pulse, at a fluence at least an order of magnitude above that necessary for saturation. Results obtained for both constant pump area and constant pump fluence are presented. The data are well modeled by calculating the instantaneous electrical energy loss due to the intense charge extraction at the pump site and then recalculating the gain downstream at the probe site given the pump-dependent degradation in voltage amplitude

  8. Creep analysis of fuel plates for the Advanced Neutron Source

    International Nuclear Information System (INIS)

    Swinson, W.F.; Yahr, G.T.

    1994-11-01

    The reactor for the planned Advanced Neutron Source will use closely spaced arrays of fuel plates. The plates are thin and will have a core containing enriched uranium silicide fuel clad in aluminum. The heat load caused by the nuclear reactions within the fuel plates will be removed by flowing high-velocity heavy water through narrow channels between the plates. However, the plates will still be at elevated temperatures while in service, and the potential for excessive plate deformation because of creep must be considered. An analysis to include creep for deformation and stresses because of temperature over a given time span has been performed and is reported herein

  9. Microscopic Holography for flow over rough plate

    Science.gov (United States)

    Talapatra, Siddharth; Hong, Jiarong; Lu, Yuan; Katz, Joseph

    2008-11-01

    Our objective is to measure the near wall flow structures in a turbulent channel flow over a rough wall. In-line microscopic holographic PIV can resolve the 3-D flow field in a small sample volume, but recording holograms through a rough surface is a challenge. To solve this problem, we match the refractive indices of the fluid with that of the wall. Proof of concept tests involve an acrylic plate containing uniformly distributed, closely packed 0.45mm high pyramids with slope angle of 22^^o located within a concentrated sodium iodide solution. Holograms recorded by a 4864 x 3248 pixel digital camera at 10X magnification provide a field of view of 3.47mm x 2.32mm and pixel resolution of 0.714 μm. Due to index matching, reconstructed seed particles can be clearly seen over the entire volume, with only faint traces with the rough wall that can be removed. Planned experiments will be performed in a 20 x 5 cm rectangular channel with the top and bottom plates having the same roughness as the sample plate.

  10. Bipolar plates for PEM fuel cells

    Science.gov (United States)

    Middelman, E.; Kout, W.; Vogelaar, B.; Lenssen, J.; de Waal, E.

    The bipolar plates are in weight and volume the major part of the PEM fuel cell stack, and are also a significant contributor to the stack costs. The bipolar plate is therefore a key component if power density has to increase and costs must come down. Three cell plate technologies are expected to reach targeted cost price levels, all having specific advantages and drawbacks. NedStack has developed a conductive composite materials and a production process for fuel cell plates (bipolar and mono-polar). The material has a high electric and thermal conductivity, and can be processed into bipolar plates by a proprietary molding process. Process cycle time has been reduced to less than 10 s, making the material and process suitable for economical mass production. Other development work to increase material efficiency resulted in thin bipolar plates with integrated cooling channels, and integrated seals, and in two-component bipolar plates. Total thickness of the bipolar plates is now less than 3 mm, and will be reduced to 2 mm in the near future. With these thin integrated plates it is possible to increase power density up to 2 kW/l and 2 kW/kg, while at the same time reducing cost by integrating other functions and less material use.

  11. Manejo da podridão de melão pelo controle do amadurecimento através do 1-mcp, sob duas condições de armazenamento Melon rot management by ripening control whith 1-MCP treatment under two storage conditions

    Directory of Open Access Journals (Sweden)

    Daniel Terao

    2009-06-01

    Full Text Available Objetivou-se neste trabalho avaliar o efeito de 1-MCP (300 nL.L¹ nas alterações fisiológicas que ocorrem durante o amadurecimento do melão, tipo Orange cv. Orange Flesh e sua influência no controle da podridão causada por Fusarium pallidoroseum, em dois ambientes de armazenamento, sem refrigeração (29 ± 1 ºC e umidade relativa de 65 ± 2 % e refrigerado (10 ± 2 ºC e umidade relativa 90 ± 3 % durante 15 dias e nove dias adicionais em condição ambiente. Avaliouse a atividade respiratória, produção de etileno, perda de matéria fresca, cor da casca e da polpa, firmeza da polpa, pH, acidez total titulável, sólidos solúveis totais, açúcares solúveis totais e severidade da doença. O delineamento foi inteiramente casualizado em arranjo fatorial com quatro repetições/tratamento. Frutos tratados com 1-MCP, armazenados em ambiente sem refrigeração, mantiveram firmeza da polpa praticamente inalterada até o 15º dia e quando em refrigeração mantiveram-se inalterados até o final da avaliação aos 24 dias após a colheita, retardando também a abscisão do pedúnculo, uma variável indicativa de maturação. O tratamento com 1-MCP retardou o amadurecimento de frutos controlando a podridão de F. pallidoroseum. Este tratamento também reduziu a respiração, produção, etileno, perda de peso, não influenciando significativamente as variáveis de qualidade do fruto: coloração da casca e polpa dos frutos, teor de sólidos solúveis totais e açúcares solúveis totais durante o período de armazenamento, bem como pH e acidez total titulável nas diferentes condições de armazenamento estudadas. A refrigeração interagiu positivamente com o 1-MCP, aumentando o tempo de conservação e sanidade do melão.The objective of this experiment was to evaluate the effect of 1-replicates. Fruit treated with 1-MCP stored at room temperature MCP (at 300 nL.L-1on de physiological changes occurring during kept the pulp firmness until 15

  12. Cigarette smoke-related hydroquinone dysregulates MCP-1, VEGF and PEDF expression in retinal pigment epithelium in vitro and in vivo.

    Directory of Open Access Journals (Sweden)

    Marianne Pons

    2011-02-01

    Full Text Available Age-related macular degeneration (AMD is the leading cause of legal blindness in the elderly population. Debris (termed drusen below the retinal pigment epithelium (RPE have been recognized as a risk factor for dry AMD and its progression to wet AMD, which is characterized by choroidal neovascularization (CNV. The underlying mechanism of how drusen might elicit CNV remains undefined. Cigarette smoking, oxidative damage to the RPE and inflammation are postulated to be involved in the pathophysiology of the disease. To better understand the cellular mechanism(s linking oxidative stress and inflammation to AMD, we examined the expression of pro-inflammatory monocyte chemoattractant protein-1 (MCP-1, pro-angiogenic vascular endothelial growth factor (VEGF and anti-angiogenic pigment epithelial derived factor (PEDF in RPE from smoker patients with AMD. We also evaluated the effects of hydroquinone (HQ, a major pro-oxidant in cigarette smoke on MCP-1, VEGF and PEDF expression in cultured ARPE-19 cells and RPE/choroids from C57BL/6 mice.MCP-1, VEGF and PEDF expression was examined by real-time PCR, Western blot, and ELISA. Low levels of MCP-1 protein were detected in RPE from AMD smoker patients relative to controls. Both MCP-1 mRNA and protein were downregulated in ARPE-19 cells and RPE/choroids from C57BL/6 mice after 5 days and 3 weeks of exposure to HQ-induced oxidative injury. VEGF protein expression was increased and PEDF protein expression was decreased in RPE from smoker patients with AMD versus controls resulting in increased VEGF/PEDF ratio. Treatment with HQ for 5 days and 3 weeks increased the VEGF/PEDF ratio in vitro and in vivo.We propose that impaired RPE-derived MCP-1-mediated scavenging macrophages recruitment and phagocytosis might lead to incomplete clearance of proinflammatory debris and infiltration of proangiogenic macrophages which along with increased VEGF/PEDF ratio favoring angiogenesis might promote drusen accumulation and

  13. Cooled electronic system with liquid-cooled cold plate and thermal spreader coupled to electronic component

    Science.gov (United States)

    Chainer, Timothy J.; Graybill, David P.; Iyengar, Madhusudan K.; Kamath, Vinod; Kochuparambil, Bejoy J.; Schmidt, Roger R.; Steinke, Mark E.

    2018-03-27

    Apparatus and method are provided for facilitating cooling of an electronic component. The apparatus includes a liquid-cooled cold plate and a thermal spreader associated with the cold plate. The cold plate includes multiple coolant-carrying channel sections extending within the cold plate, and a thermal conduction surface with a larger surface area than a surface area of the component to be cooled. The thermal spreader includes one or more heat pipes including multiple heat pipe sections. One or more heat pipe sections are partially aligned to a first region of the cold plate, that is, where aligned to the surface to be cooled, and partially aligned to a second region of the cold plate, which is outside the first region. The one or more heat pipes facilitate distribution of heat from the electronic component to coolant-carrying channel sections of the cold plate located in the second region of the cold plate.

  14. Microchannel plate assembly parameters with micron gaps

    International Nuclear Information System (INIS)

    Demchenkova, A.A.

    1987-01-01

    Performance of chevron microchannel plate assembly with 5 and 15 μm gaps between them has been investigated. The assembly is placed into a vacuum chamber under pressure -6 Torr and irradiated by neutral He and Ar atom beams with 1.5 and 3 keV energies as well as by ultraviolet photons with 147 nm wave length. Dependence of the gain and amplitude resolution on power voltage in plates are measured. The results obtained have shown that microchannel plates permit to obtain the gain up to 3x10 7 and amplitude resolution up to 30% when detecting both atomic particles and ultraviolet photons. The assembly can be effectively used in those cases when it is necessary to use microchannel plates with curved channels

  15. State of art report for high temperature wear test of SMART MCP and CEDM bearing material

    International Nuclear Information System (INIS)

    Cho, Yong Hu; Lee, Jae Seon; Park, Jin Seok; Kim, Ji Ho; Kim, Jong In

    2000-03-01

    Wear resistance properties of machine elements has been more critical in view of its significant effect on life extension, economics and material saving because it has been recognized that nearly 80 percent of damages of mechanical elements in the friction pairs are due to the material loss by wear. And wear properties have direct influence on the life of a machine in a great extend under extremely severe operating condition. Therefore highly improved wear properties of machine elements operating in such circumstances is heavily required. The purpose of this report is to survey current technology for high temperature wear test in order to establish the test plan for the life evaluation of SMART MCP and CEDM bearing materials. Friction and wear test will be done under high pressure (170 MPa) and high temperature (350 degree C) with water as lubricant to simulate the operating condition of the nuclear power reactor. Because pump type for MCP is selected as the caned motor pump which needs no mechanical sealing, the rotating shaft on which bearing is fully submerged by main coolant with high temperature. So MCP bearing operates without additional lubricant. CEDM is adopted as the ball-screw type with fine controllability. So the driving part is designed as the immersed-in type by main coolant. Therefore the anti-wear and reliability of driving parts are much consequent to guarantee the lifetime and the safety of the whole system. Tribometer adapted to high temperature and pressure circumstance is needed to execute bearing material testing. Test parameters are material, sliding speed, sliding distance and applied load. In order to identify the wear mechanism, optical microscope and surface roughness testers are required. The result of this report will provide an elementary data to develop bearing materials and to estimate bearing lifetime for the bearings of MCP and CEDM in SMART. (author)

  16. Ethylene and 1-MCP affect the postharvest behavior of yellow pitahaya fruits (Selenicereus megalanthus Haw.

    Directory of Open Access Journals (Sweden)

    Yuli Alexandra Deaquiz

    2014-04-01

    Full Text Available The pitahaya or dragon fruit is one of the most representative exotic fruits that Colombia has, with an important, growing international market, but the cultivation and postharvest of this fruit lack sufficient technological support to be more competitive. Therefore, alternatives that provide good-quality products that meet market requirements are very important. Therefore, the objective of this research was to determine the effect of a ripening retardant and ethylene application on the conservation and quality of pitahaya fruits and the possible changes during ripening associated with ethylene, for which a completely randomized design with three treatments was used, corresponding to the application of ethylene (ethephon, 3 mL L-1, 1-methylcyclopropene (1-MCP, 600 mg L-1 and a control, with four replications, for a total of 12 experimental units. The fruits were stored at 18°C with 75% relative humidity. The 1-MCP application significantly decreased the loss of firmness, total soluble solids, loss of fresh mass and respiratory rate. Fruits from the control and ethylene treatment tended toward a climateric respiratory behavior. The total carotenoid content of the fruits was significantly higher in the ethylene application and the control treatment, which was consistent with the color change of the fruits. It can be concluded that the 1-MCP application reduced the ethylene action, slowing the ripening of the dragon fruits.

  17. Comparison of the Effect of 1-MCP and Low-Pressure Air on Shelflife of Strawberry Fruit (Fragaria ananassa cv. Camarossa

    Directory of Open Access Journals (Sweden)

    B. Modares

    2013-10-01

    Full Text Available Strawberry (Fragaria×ananassa has tasteful, fragrant and nutritious fruits. But, because of delicate texture and high metabolic activities of the fruits at maturity, are very sensitive and easily decayed, and thus have short shelflife. Ethylene is one of the main causes of postharvest fruit losses, which could reduce the shelflife of strawberry. Therefore, an experiment was carried out to examine the effect of 1 µL/L 1-MCP treatment and low-pressure air pretreatment at 0.2 atm in 2 hours on apparent and physicochemical characteristics of strawberry fruit, cultivar Camarossa, during storage in cold store. The study was performed as split plots in time, based on complete randomized design with 3 replications. The results showed that the highest marketability (90%, fruit firmness (7.95 N, titrable organic acids (1.15 g/100 cc, vitamin C (78.13 mg/100 cc and total soluble solids (10.48 % and the lowest amount of apparent decay (13.3 %, acidity (3.63 and taste index (9.04 were obtained in 1-MCP and low-pressure air treatments, which shows the effect of treatments on reducing the rate of biochemical variations in fruit texture. Correlation coefficients between all treatments were significant (P≤0.01. Meanwhile, the positive effect of 1-MCP on appearance and studied physicochemical characteristics was more than low-pressure air pretreatment. Even, the combination of these two treatments had no significant difference with 1-MCp treatment alone. In general, this observation depicts the more positive and significant effect of 1-MCP treatment in delaying the maturity and improving the qualitative traits of strawberry fruits after being stored in cold storage.

  18. Implementation of 40-ps high-speed gated-microchannel-plate based x-ray framing cameras on reentrant SIM's for Nova

    International Nuclear Information System (INIS)

    Bell, P.M.; Kilkenny, J.D.; Landen, O.; Bradley, D.K.

    1994-01-01

    Gated framing cameras used in diagnosing laser produced plasmas have been used on the Nova laser system since 1987. There have been many variations of these systems implemented. All of these cameras have been ultimately limited in response time for two reasons. One being the electrical gating amplitude verses the gate width, this has always limited the detectable gain in the system. The second being the length to diameter (l/d) ratio of standard off the shelf microchannel plates (MCP). This sets the minimum electrical gate pulse that will give detectable gain from a given microchannel plate. The authors have implemented two different types of 40 ps framing camera configurations on the Nova laser system. They will describe the configurations of both systems as well as discuss the advantages of each

  19. Non-destructive beam profile monitor at HIMAC

    International Nuclear Information System (INIS)

    Sato, S.; Araki, N.; Hosaka, M.

    1995-01-01

    Non-destructive profile monitors (NDPM), based on micro-channel plate (MCP), have been developed and installed in both the synchrotron ring and high-energy beam transport (HEBT) line at HIMAC. Beam test using these monitors have been carried out since April of 1995 to investigate a change of vertical beam size in synchrotron and a possibility of observing beam with high energy by one pass. In this paper the measurement system is mainly reported, and the preliminary results are also briefly presented. (author)

  20. A new XUV optical end-station to characterize compact and flexible photonic devices using synchrotron radiation

    Science.gov (United States)

    Marcelli, A.; Mazuritskiy, M. I.; Dabagov, S. B.; Hampai, D.; Lerer, A. M.; Izotova, E. A.; D'Elia, A.; Turchini, S.; Zema, N.; Zuccaro, F.; de Simone, M.; Javad Rezvani, S.; Coreno, M.

    2018-03-01

    In this contribution we present the new experimental end-station to characterize XUV diffractive optics, such as Micro Channel Plates (MCPs) and other polycapillary optics, presently under commission at the Elettra synchrotron radiation laboratory (Trieste, Italy). To show the opportunities offered by these new optical devices for 3rd and 4th generation radiation sources, in this work we present also some patterns collected at different energies of the primary XUV radiation transmitted by MCP optical devices working in the normal incidence geometry.

  1. Flow field bipolar plates in a proton exchange membrane fuel cell: Analysis & modeling

    International Nuclear Information System (INIS)

    Kahraman, Huseyin; Orhan, Mehmet F.

    2017-01-01

    Highlights: • Covers a comprehensive review of available flow field channel configurations. • Examines the main design considerations and limitations for a flow field network. • Explores the common materials and material properties used for flow field plates. • Presents a case study of step-by-step modeling for an optimum flow field design. - Abstract: This study investigates flow fields and flow field plates (bipolar plates) in proton exchange membrane fuel cells. In this regard, the main design considerations and limitations for a flow field network have been examined, along with a comprehensive review of currently available flow field channel configurations. Also, the common materials and material properties used for flow field plates have been explored. Furthermore, a case study of step-by-step modeling for an optimum flow field design has been presented in-details. Finally, a parametric study has been conducted with respect to many design and performance parameters in a flow field plate.

  2. Combination of IL-6, IL-10, and MCP-1 with traditional serum tumor markers in lung cancer diagnosis and prognosis.

    Science.gov (United States)

    Pan, Y W; Zhou, Z G; Wang, M; Dong, J Q; Du, K P; Li, S; Liu, Y L; Lv, P J; Gao, J B

    2016-11-03

    Early detection and treatment is critically important for lung cancer patients. Inflammatory mediators such as IL-6, IL-10, and MCP-1 participate in lung cancer regulation. CEA, CA125, and ProGRP are commonly used serum tumor markers for lung cancer. In this study, we assessed the sensitivity and specificity of CEA, CA125, and ProGRP when used in combination with IL-6, IL-10, and MCP in lung cancer diagnosis. Serum from three different groups (healthy controls, individuals with high risk for lung cancer, and lung cancer patients) was collected. Electrochemiluminescence was used to detect expressions of CEA, CA125, and ProGRP; ELISA was used to examine serum levels of IL-6, IL-10, and MCP-1. Specificity and sensitivity of single as well as combination markers in lung cancer diagnosis were determined. Results indicated that CEA, CA125, ProGRP, and MCP-1 were significantly up-regulated in lung cancer patients as compared to those in controls and high risk individuals. Higher IL-6 and IL-10 levels were observed in both lung cancer patients and high-risk individuals as compared to those in controls. Highest sensitivity (95.2%) in cancer diagnosis was achieved when all six markers were used. This was followed by a combination of IL-6, IL-10, CEA, CA125, and ProGRP (92.6%). The most sensitive (88.6%). Four-marker combination was composed of IL-6, CEA, CA125, and ProGRP. As the combined usage of CEA, CA125, ProGRP, IL-6, IL-10, and MCP-1 significantly improved sensitivity of lung cancer detection; this biomarker arrangement may be beneficial for early diagnosis, treatment, and prognosis of lung cancer.

  3. Development and tests of MCP based timing and multiplicity detector for MIPs

    Science.gov (United States)

    Feofilov, G.; Kondratev, V.; Stolyarov, O.; Tulina, T.; Valiev, F.; Vinogradov, L.

    2017-01-01

    We present summary of technological developments and tests of the MCP based large area detector aimed at precise timing and charged particles multiplicity measurements. Results obtained in course of these developments of isochronous (simultaneity) precise signal readout, passive summation of 1 ns signals, fast (1 GHz) front-end electronics, miniature vacuum systems, etc. could be potentially interesting for a number of future applications in different fields.

  4. Plasma cytokines eotaxin, MIP-1α, MCP-4, and vascular endothelial growth factor in acute lower respiratory tract infection

    DEFF Research Database (Denmark)

    Relster, Mette Marie; Holm, Anette; Pedersen, Court

    2017-01-01

    ), monocyte chemoattractant protein 4 (MCP-4), and vascular endothelial growth factor (VEGF) in 40 patients hospitalized with acute lower respiratory tract infections (LRTI). The cytokines contribute to the pathogenesis of several inflammatory respiratory diseases, indicating a potential as markers for LRTI....... Patients were stratified according to etiology and severity of LRTI, based on baseline C-reactive protein and CURB-65 scores. Using a multiplex immunoassay of plasma, levels of eotaxin and MCP-4 were shown to increase from baseline until day 6 after admission to hospital. The four cytokines were unable...

  5. A field study evaluation of Petrifilm™ plates as a 24-h rapid diagnostic test for clinical mastitis on a dairy farm.

    Science.gov (United States)

    Mansion-de Vries, Elisabeth Maria; Knorr, Nicole; Paduch, Jan-Hendrik; Zinke, Claudia; Hoedemaker, Martina; Krömker, Volker

    2014-03-01

    Clinical mastitis is one of the most common and expensive diseases of dairy cattle. To make an informed treatment decision, it is important to know the causative pathogen. However, no detection of bacterial growth can be made in approximately 30% of all clinical cases of mastitis. Before selecting the treatment regimen, it is important to know whether the mastitis-causing pathogen (MCP) is Gram-positive or Gram-negative. The aim of this field study was to investigate whether using two 3M Petrifilm™ products on-farm (which conveys a higher degree of sample freshness but also bears a higher risk for contamination than working in a lab) as 24-h rapid diagnostic of clinical mastitis achieved results that were comparable to the conventional microbiological diagnostic method. AerobicCount (AC)-Petrifilm™ and ColiformCount (CC)-Petrifilm™ were used to identify the total bacterial counts and Gram-negative bacteria in samples from clinical mastitis cases, respectively. Missing growth on both plates was classified as no bacterial detection. Growth only on the AC-Petrifilm™ was assessed as Gram-positive, and growth on both Petrifilm™ plates was assessed as Gram-negative bacterial growth. Additionally, milk samples were analysed by conventional microbiological diagnostic method on aesculin blood agar as a reference method. Overall, 616 samples from clinical mastitis cases were analysed. Using the reference method, Gram-positive and Gram-negative bacteria, mixed bacterial growth, contaminated samples and yeast were determined in 32.6%, 20.0%, 2.5%, 14.1% and 1.1% of the samples, respectively. In 29.7% of the samples, microbiological growth could not be identified. Using the Petrifilm™ concept, bacterial growth was detected in 59% of the culture-negative samples. The sensitivity of the Petrifilm™ for Gram-positive and Gram-negative MCP was 85.2% and 89.9%, respectively. The specificity was 75.4% for Gram-positive and 88.4% for Gram-negative MCP. For the culture

  6. Storage of strawberries (Fragaria ananassa L. cv. ‘Oso Grande’, subjected to 1-MCP - doi: 10.4025/actascitechnol.v34i3.8790

    Directory of Open Access Journals (Sweden)

    Polyanna Alves Silva

    2012-05-01

    Full Text Available This study aimed to investigate the influence of 1 - methylcyclopropene (1-MCP on the substances involved in the softening of strawberry, cultivar Oso Grande, stored at room temperature, from the municipality of Itutinga, State of Minas Gerais. The parameters evaluated were: firmness, total pectin, percentage of solubilization, activities of the enzymes pectinmethylesterase (PME (EC 3.1.1.11 and polygalacturonase (PG (EC 3.2.1.15. It was concluded that 1-MCP delayed the softening of the fruits, since the fruits that were treated with 1-MCP after storage, have shown greater firmness, lower activities of PG and PME, and lower contents of total pectin, soluble pectin and percentage of solubilization. 

  7. A High-Speed, Event-Driven, Active Pixel Sensor Readout for Photon-Counting Microchannel Plate Detectors

    Science.gov (United States)

    Kimble, Randy A.; Pain, Bedabrata; Norton, Timothy J.; Haas, J. Patrick; Oegerle, William R. (Technical Monitor)

    2002-01-01

    Silicon array readouts for microchannel plate intensifiers offer several attractive features. In this class of detector, the electron cloud output of the MCP intensifier is converted to visible light by a phosphor; that light is then fiber-optically coupled to the silicon array. In photon-counting mode, the resulting light splashes on the silicon array are recognized and centroided to fractional pixel accuracy by off-chip electronics. This process can result in very high (MCP-limited) spatial resolution while operating at a modest MCP gain (desirable for dynamic range and long term stability). The principal limitation of intensified CCD systems of this type is their severely limited local dynamic range, as accurate photon counting is achieved only if there are not overlapping event splashes within the frame time of the device. This problem can be ameliorated somewhat by processing events only in pre-selected windows of interest of by using an addressable charge injection device (CID) for the readout array. We are currently pursuing the development of an intriguing alternative readout concept based on using an event-driven CMOS Active Pixel Sensor. APS technology permits the incorporation of discriminator circuitry within each pixel. When coupled with suitable CMOS logic outside the array area, the discriminator circuitry can be used to trigger the readout of small sub-array windows only when and where an event splash has been detected, completely eliminating the local dynamic range problem, while achieving a high global count rate capability and maintaining high spatial resolution. We elaborate on this concept and present our progress toward implementing an event-driven APS readout.

  8. Parallel channel effects under BWR LOCA conditions

    International Nuclear Information System (INIS)

    Suzuki, H.; Hatamiya, S.; Murase, M.

    1988-01-01

    Due to parallel channel effects, different flow patterns such as liquid down-flow and gas up-flow appear simultaneously in fuel bundles of a BWR core during postulated LOCAs. Applying the parallel channel effects to the fuel bundle, water drain tubes with a restricted bottom end have been developed in order to mitigate counter-current flow limiting and to increase the falling water flow rate at the upper tie plate. The upper tie plate with water drain tubes is an especially effective means of increasing the safety margin of a reactor with narrow gaps between fuel rods and high steam velocity at the upper tie plate. The characteristics of the water drain tubes have been experimentally investigated using a small-scaled steam-water system simulating a BWR core. Then, their effect on the fuel cladding temperature was evaluated using the LOCA analysis program SAFER. (orig.)

  9. Nuclear NF-κB p65 in peripheral blood mononuclear cells correlates with urinary MCP-1, RANTES and the severity of type 2 diabetic nephropathy.

    Directory of Open Access Journals (Sweden)

    Bin Yi

    Full Text Available AIMS: To investigate if nuclear NF-κB p65 expression in ex vivo isolated peripheral blood mononuclear cells correlates with urinary MCP-1 or RANTES and the severity of type 2 diabetic nephropathy. METHODS: According to their urinary albumin-to-creatinine ratio (uACR, 107 patients with type 2 diabetes (eGFR >60 ml/min were divided into normal albuminuria group (DN0 group, 38 cases, microalbuminuria group (DN1 group, 38 cases, and macroalbuminuria group (DN2 group, 31 cases, compared with matched healthy normal control group (NC group, 30 cases. Nuclear NF-κB p65 protein expression levels in peripheral blood mononuclear cells were detected by western blotting. Real-time quantitative polymerase chain reaction was used to detect NF-κB p65 mRNA expression and ELISA assay was used to detect the levels of urinary MCP-1 and RANTES. RESULTS: Nuclear NF-κB p65 protein and NF-κB p65 mRNA expression levels in peripheral blood mononuclear cells, urinary MCP-1/Cr and RANTES/Cr were all significantly higher in all diabetes groups as compared with NC group. In particular, the increase of nuclear NF-κB p65 protein and NF-κB p65 mRNA expressions, urinary MCP-1/Cr and RANTES/Cr all correlated with the severity of type 2 diabetic nephropathy as indicated by the increase in uACR. Pearson correlation analysis indicated that both urinary MCP-1/Cr and RANTES/Cr were positively correlated with nuclear NF-κB p65 protein or NF-κB p65 mRNA levels. Stepwise multiple regression analysis showed that nuclear NF-κB p65 protein or NF-κB p65 mRNA was an independent variable for urinary MCP-1/Cr, and MCP-1/Cr and RANTES/Cr were two independent variables for uACR. CONCLUSION: Our research demonstrates that nuclear NF-κB p65 protein and mRNA expressions in ex vivo isolated peripheral blood mononuclear cells well correlate with urinary MCP-1/Cr, RANTES/Cr and the severity of type 2 diabetic nephropathy.

  10. Detection, Quantification, and Microlocalisation of Targets of Pesticides Using Microchannel Plate Autoradiographic Imagers

    Directory of Open Access Journals (Sweden)

    Mabruka H. Tarhoni

    2011-10-01

    Full Text Available Organophosphorus (OP compounds are a diverse chemical group that includes nerve agents and pesticides. They share a common chemical signature that facilitates their binding and adduction of acetylcholinesterase (AChE within nerve synapses to induce cholinergic toxicity. However, this group diversity results in non-uniform binding and inactivation of other secondary protein targets, some of which may be adducted and protein activity influenced, even when only a relatively minor portion of tissue AChE is inhibited. The determination of individual OP protein binding targets has been hampered by the sensitivity of methods of detection and quantification of protein-pesticide adducts. We have overcome this limitation by the employment of a microchannel plate (MCP autoradiographic detector to monitor a radiolabelled OP tracer compound. We preincubated rat thymus tissue in vitro with the OP pesticides, azamethiphos-oxon, chlorfenvinphos-oxon, chlorpyrifos-oxon, diazinon-oxon, and malaoxon, and then subsequently radiolabelled the free OP binding sites remaining with 3H-diisopropylfluorophosphate (3H-DFP. Proteins adducted by OP pesticides were detected as a reduction in 3H-DFP radiolabelling after protein separation by one dimensional polyacrylamide gel electrophoresis and quantitative digital autoradiography using the MCP imager. Thymus tissue proteins of molecular weights ~28 kDa, 59 kDa, 66 kDa, and 82 kDa displayed responsiveness to adduction by this panel of pesticides. The 59 kDa protein target (previously putatively identified as carboxylesterase I was only significantly adducted by chlorfenvinphos-oxon (p < 0.001, chlorpyrifos-oxon (p < 0.0001, and diazinon-oxon (p < 0.01, the 66 kDa protein target (previously identified as serum albumin similarly only adducted by the same three pesticides (p < 0.0001, (p < 0.001, and (p < 0.01, and the 82 kDa protein target (previously identified as acyl peptide hydrolase only adducted by chlorpyrifos-oxon (p

  11. Spatially and Temporally Regulated NRF2 Gene Therapy Using Mcp-1 Promoter in Retinal Ganglion Cell Injury

    Directory of Open Access Journals (Sweden)

    Kosuke Fujita

    2017-06-01

    Full Text Available Retinal ganglion cell degeneration triggered by axonal injury is believed to underlie many ocular diseases, including glaucoma and optic neuritis. In these diseases, retinal ganglion cells are affected unevenly, both spatially and temporally, such that healthy and unhealthy cells coexist in different patterns at different time points. Herein, we describe a temporally and spatially regulated adeno-associated virus gene therapy aiming to reduce undesired off-target effects on healthy retinal neurons. The Mcp-1 promoter previously shown to be activated in stressed retinal ganglion cells following murine optic nerve injury was combined with the neuroprotective intracellular transcription factor Nrf2. In this model, Mcp-1 promoter-driven NRF2 expression targeting only stressed retinal ganglion cells showed efficacy equivalent to non-selective cytomegalovirus promoter-driven therapy for preventing cell death. However, cytomegalovirus promoter-mediated NRF2 transcription induced cellular stress responses and death of Brn3A-positive uninjured retinal ganglion cells. Such undesired effects were reduced substantially by adopting the Mcp-1 promoter. Combining a stress-responsive promoter and intracellular therapeutic gene is a versatile approach for specifically targeting cells at risk of degeneration. This strategy may be applicable to numerous chronic ocular and non-ocular conditions.

  12. Real-time imaging of radioisotope labeled compounds in a living plant

    International Nuclear Information System (INIS)

    Kanno, S.; Ohya, T.; Hayashi, Y.; Tanoi, K.; Nakanishi, T.M.

    2007-01-01

    We developed a quantitative, real-time imaging system of labeled compounds in a living plant. The system was composed of CsI scintillator to convert β-rays to visible light and an image intensifier unit (composed of GaAsP semiconductor and MCP; micro channel plate) to detect extremely weak light. When the sensitivity and resolution of the image of our system was compared with that of an imaging plate (IP), the sensitivity of our system (with 20 minutes) was higher than that of an IP, with similar quality to that of an IP. Using this system, the translocation of 32 P in a soybean plant tissue was shown in successive images. (author)

  13. Analysis of dynamic enhancement of natural convection cooling by a discrete vibrating plate

    Energy Technology Data Exchange (ETDEWEB)

    Florio, L.A.; Harnoy, A. [New Jersey Institute of Technology, Department of Mechanical Engineering, Newark, NJ (United States)

    2006-12-15

    A dynamic means of locally enhancing laminar natural convection cooling in a vertical channel through the localized application of fluid oscillations is numerically investigated. The two-dimensional system considered for these purposes is a vertical channel with a small transversely oscillating plate placed near a constant heat flux channel wall. The flow and heat transfer in the system resulting from the combined effects of the natural convection and the oscillating plate were determined. The results indicate that for displacement amplitudes of at least one-third of the mean spacing and with dimensionless frequencies (Re/{radical}(Gr)) of at least 2{pi}, the local heat transfer coefficient can be enhanced by as much as 41%. (orig.)

  14. Joint effect of MCP-1 genotype GG and MMP-1 genotype 2G/2G increases the likelihood of developing pulmonary tuberculosis in BCG-vaccinated individuals.

    Directory of Open Access Journals (Sweden)

    Malathesha Ganachari

    2010-01-01

    Full Text Available We previously reported that the -2518 MCP-1 genotype GG increases the likelihood of developing tuberculosis (TB in non-BCG-vaccinated Mexicans and Koreans. Here, we tested the hypothesis that this genotype, alone or together with the -1607 MMP-1 functional polymorphism, increases the likelihood of developing TB in BCG-vaccinated individuals. We conducted population-based case-control studies of BCG-vaccinated individuals in Mexico and Peru that included 193 TB cases and 243 healthy tuberculin-positive controls from Mexico and 701 TB cases and 796 controls from Peru. We also performed immunohistochemistry (IHC analysis of lymph nodes from carriers of relevant two-locus genotypes and in vitro studies to determine how these variants may operate to increase the risk of developing active disease. We report that a joint effect between the -2518 MCP-1 genotype GG and the -1607 MMP-1 genotype 2G/2G consistently increases the odds of developing TB 3.59-fold in Mexicans and 3.9-fold in Peruvians. IHC analysis of lymph nodes indicated that carriers of the two-locus genotype MCP-1 GG MMP-1 2G/2G express the highest levels of both MCP-1 and MMP-1. Carriers of these susceptibility genotypes might be at increased risk of developing TB because they produce high levels of MCP-1, which enhances the induction of MMP-1 production by M. tuberculosis-sonicate antigens to higher levels than in carriers of the other two-locus MCP-1 MMP-1 genotypes studied. This notion was supported by in vitro experiments and luciferase based promoter activity assay. MMP-1 may destabilize granuloma formation and promote tissue damage and disease progression early in the infection. Our findings may foster the development of new and personalized therapeutic approaches targeting MCP-1 and/or MMP-1.

  15. Joint effect of MCP-1 genotype GG and MMP-1 genotype 2G/2G increases the likelihood of developing pulmonary tuberculosis in BCG-vaccinated individuals.

    Science.gov (United States)

    Ganachari, Malathesha; Ruiz-Morales, Jorge A; Gomez de la Torre Pretell, Juan C; Dinh, Jeffrey; Granados, Julio; Flores-Villanueva, Pedro O

    2010-01-25

    We previously reported that the -2518 MCP-1 genotype GG increases the likelihood of developing tuberculosis (TB) in non-BCG-vaccinated Mexicans and Koreans. Here, we tested the hypothesis that this genotype, alone or together with the -1607 MMP-1 functional polymorphism, increases the likelihood of developing TB in BCG-vaccinated individuals. We conducted population-based case-control studies of BCG-vaccinated individuals in Mexico and Peru that included 193 TB cases and 243 healthy tuberculin-positive controls from Mexico and 701 TB cases and 796 controls from Peru. We also performed immunohistochemistry (IHC) analysis of lymph nodes from carriers of relevant two-locus genotypes and in vitro studies to determine how these variants may operate to increase the risk of developing active disease. We report that a joint effect between the -2518 MCP-1 genotype GG and the -1607 MMP-1 genotype 2G/2G consistently increases the odds of developing TB 3.59-fold in Mexicans and 3.9-fold in Peruvians. IHC analysis of lymph nodes indicated that carriers of the two-locus genotype MCP-1 GG MMP-1 2G/2G express the highest levels of both MCP-1 and MMP-1. Carriers of these susceptibility genotypes might be at increased risk of developing TB because they produce high levels of MCP-1, which enhances the induction of MMP-1 production by M. tuberculosis-sonicate antigens to higher levels than in carriers of the other two-locus MCP-1 MMP-1 genotypes studied. This notion was supported by in vitro experiments and luciferase based promoter activity assay. MMP-1 may destabilize granuloma formation and promote tissue damage and disease progression early in the infection. Our findings may foster the development of new and personalized therapeutic approaches targeting MCP-1 and/or MMP-1.

  16. Atomic layer deposition of alternative glass microchannel plates

    Energy Technology Data Exchange (ETDEWEB)

    O' Mahony, Aileen, E-mail: aom@incomusa.com; Craven, Christopher A.; Minot, Michael J.; Popecki, Mark A.; Renaud, Joseph M.; Bennis, Daniel C.; Bond, Justin L.; Stochaj, Michael E.; Foley, Michael R.; Adams, Bernhard W. [Incom, Inc., 294 Southbridge Road, Charlton, Massachusetts 01507 (United States); Mane, Anil U.; Elam, Jeffrey W. [Argonne National Laboratory, 9700 S. Cass Ave., Argonne, Illinois 60439 (United States); Ertley, Camden; Siegmund, Oswald H. W. [Space Sciences Laboratory, University of California, 7 Gauss Way, Berkeley, California 94720 (United States)

    2016-01-15

    The technique of atomic layer deposition (ALD) has enabled the development of alternative glass microchannel plates (MCPs) with independently tunable resistive and emissive layers, resulting in excellent thickness uniformity across the large area (20 × 20 cm), high aspect ratio (60:1 L/d) glass substrates. Furthermore, the use of ALD to deposit functional layers allows the optimal substrate material to be selected, such as borosilicate glass, which has many benefits compared to the lead-oxide glass used in conventional MCPs, including increased stability and lifetime, low background noise, mechanical robustness, and larger area (at present up to 400 cm{sup 2}). Resistively stable, high gain MCPs are demonstrated due to the deposition of uniform ALD resistive and emissive layers on alternative glass microcapillary substrates. The MCP performance characteristics reported include increased stability and lifetime, low background noise (0.04 events cm{sup −2} s{sup −1}), and low gain variation (±5%)

  17. Multi-channel polarized thermal emitter

    Science.gov (United States)

    Lee, Jae-Hwang; Ho, Kai-Ming; Constant, Kristen P

    2013-07-16

    A multi-channel polarized thermal emitter (PTE) is presented. The multi-channel PTE can emit polarized thermal radiation without using a polarizer at normal emergence. The multi-channel PTE consists of two layers of metallic gratings on a monolithic and homogeneous metallic plate. It can be fabricated by a low-cost soft lithography technique called two-polymer microtransfer molding. The spectral positions of the mid-infrared (MIR) radiation peaks can be tuned by changing the periodicity of the gratings and the spectral separation between peaks are tuned by changing the mutual angle between the orientations of the two gratings.

  18. A timing detector with pulsed high-voltage power supply for mass measurements at CSRe

    International Nuclear Information System (INIS)

    Zhang, W.; Tu, X.L.; Wang, M.; Zhang, Y.H.; Xu, H.S.; Litvinov, Yu. A.; Blaum, K.

    2014-01-01

    Accuracy of nuclear mass measurements in storage rings depends critically on the accuracy with which the revolution times of stored ions can be obtained. In such experiments, micro-channel plates (MCP) are used as timing detectors. Due to large phase space of injected secondary beams, a large number of ions cannot be stored in the ring and is lost within the first few revolutions. However, these ions interact with the detector and can saturate the MCP and thus deteriorate its performance. In order to eliminate such effects, a fast, pulsed high-voltage power supply (PHVPS) has been employed which keeps the detector switched-off during the first few revolutions. The new detector setup was taken into operation at the Experimental Cooler-Storage-Ring CSRe in Lanzhou and resulted in a significant improvement of the detector amplitude and efficiency characteristics

  19. Studies on positive conveying in helically channeled single screw extruders

    Directory of Open Access Journals (Sweden)

    L. Pan

    2012-07-01

    Full Text Available A solids conveying theory called double-flight driving theory was proposed for helically channeled single screw extruders. In the extruder, screw channel rotates against static barrel channel, which behaves as cooperative embedded twin-screws for the positive conveying. They turn as two parallel arc plates, between which an arc-plate solid-plug was assumed. By analyzing the forces on the solid-plug in the barrel channel and screw channel, the boundary conditions when the solid-plug is waived of being cut off on barrel wall, were found to have the capacity of the positive conveying. Experimental data were obtained using a specially designed extruder with a helically channeled barrel in the feeding zone and a pressure-adjustable die. The effects of the barrel channel geometry and friction coefficients on the conveying mechanism were presented and compared with the experimental results. The simulations showed that the positive conveying could be achieved after optimizing extruder designs. Compared with the traditional design with the friction-drag conveying, the throughput is higher while screw torque and energy consumption are decreased. Besides, the design criteria of the barrel channel were also discussed.

  20. Complete Flow Blockage of a Fuel Channel for Research Reactor

    International Nuclear Information System (INIS)

    Lee, Byeonghee; Park, Suki

    2015-01-01

    The CHF correlation suitable for narrow rectangular channels are implemented in RELAP5/MOD3.3 code for the analyses, and the behavior of fuel temperatures and MCHFR(minimum critical heat flux ratio) are compared between the original and modified codes. The complete flow blockage of fuel channel for research reactor is analyzed using original and modified RELAP5/MOD3.3 and the results are compared each other. The Sudo-Kaminaga CHF correlation is implemented into RELAP5/MOD3.3 for analyzing the behavior of fuel adjacent to the blocked channel. A flow blockage of fuel channels can be postulated by a foreign object blocking cooling channels of fuels. Since a research reactor with plate type fuel has isolated fuel channels, a complete flow blockage of one fuel channel can cause a failure of adjacent fuel plates by the loss of cooling capability. Although research reactor systems are designed to prevent foreign materials from entering into the core, partial flow blockage accidents and following fuel failures are reported in some old research reactors. In this report, an analysis of complete flow blockage accident is presented for a 15MW pool-type research reactor with plate type fuels. The fuel surface experience different heat transfer regime in the results from original and modified RELAP5/MOD3.3. By the discrepancy in heat transfer mode of two cases, a fuel melting is expected by the modified RELAP5/MOD3.3, whereas the fuel integrity is ensured by the original code

  1. Modeling the hydrodynamics of Phloem sieve plates

    DEFF Research Database (Denmark)

    Jensen, Kaare Hartvig; Mullendore, Daniel Leroy; Holbrook, Noel Michele

    2012-01-01

    Sieve plates have an enormous impact on the efficiency of the phloem vascular system of plants, responsible for the distribution of photosynthetic products. These thin plates, which separate neighboring phloem cells, are perforated by a large number of tiny sieve pores and are believed to play...... understood. We propose a theoretical model for quantifying the effect of sieve plates on the phloem in the plant, thus unifying and improving previous work in the field. Numerical simulations of the flow in real and idealized phloem channels verify our model, and anatomical data from 19 plant species...... a crucial role in protecting the phloem sap from intruding animals by blocking flow when the phloem cell is damaged. The resistance to the flow of viscous sap in the phloem vascular system is strongly affected by the presence of the sieve plates, but the hydrodynamics of the flow through them remains poorly...

  2. New technologies for UV detectors

    Science.gov (United States)

    Joseph, C. L.

    1993-01-01

    Several technologies are currently being developed, leading to substantial improvements in the performance of UV detectors or significant reductions in power or weight. Four technologies discussed are (1) thin-film coatings to enhance the UV sensitivity of CCD's, (2) highly innovative magnet assemblies that dramatically reduce weight and result in virtually no external flux, (3) new techniques for curving microchannel plates (MCP's) so that single plates can be used to prevent ion feedback and present highly localized charge clouds to an anode structure, and (4) high-performance alternatives to glass-based MCP's. In item (2), for example, very robust magnets are made out of rare earth materials such as samarium cobalt, and cladding magnets are employed to prevent flux from escaping from the detector into the external environment. These new ultralight magnet assemblies are able to create strong, exceptionally uniform magnetic fields for image intensification and focusing of photoelectrons. The principle advantage of such detectors is the quantum efficiencies of 70-80 percent obtained throughout ultraviolet wavelengths (900-2000 A), the highest of any device. Despite the improvements achieved under item (3), high-performance alternatives to conventional glass-based MCP's potentially offer three distinct new advantages that include (1) a 30-100-fold improvement in dynamic range resulting in correspondingly higher signal-to-noise ratios, (2) the use of pure dielectric and semiconductor materials that will not outgas contaminants that eventually destroy photocathodes, and (3) channels that have constant spacing providing long-ranged order since the plates are made using photolithography techniques from the semiconductor industry. The manufacturers of these advanced-technology MCP's, however, are a couple of years away from actually producing a functioning image intensifier. In contrast to the use of CCD's for optical, ground based observations, there is no single

  3. Muscle glycogen depletion following 75-km of cycling is not linked to increased muscle IL-6, IL-8, and MCP-1 mRNA expression and protein content

    Directory of Open Access Journals (Sweden)

    David Christopher Nieman

    2016-09-01

    Full Text Available The cytokine response to heavy exertion varies widely for unknown reasons, and this study evaluated the relative importance of glycogen depletion, muscle damage, and stress hormone changes on blood and muscle cytokine measures. Cyclists (N=20 participated in a 75-km cycling time trial (168±26.0 min, with blood and vastus lateralis muscle samples collected before and after. Muscle glycogen decreased 77.2±17.4%, muscle IL-6, IL-8, and MCP-1 mRNA increased 18.5±2.8-, 45.3±7.8-, and 8.25±1.75-fold, and muscle IL-6, IL-8, and MCP-1 protein increased 70.5±14.1%, 347±68.1%, and 148±21.3%, respectively (all, P<0.001. Serum myoglobin and cortisol increased 32.1±3.3 to 242±48.3 mg/mL, and 295±27.6 to 784±63.5 nmol/L, respectively (both P<0.001. Plasma IL-6, IL-8, and MCP-1 increased 0.42±0.07 to 18.5±3.8, 4.07±0.37 to 17.0±1.8, and 96.5±3.7 to 240±21.6 pg/mL, respectively (all P<0.001. Increases in muscle IL-6, IL-8, and MCP-1 mRNA were unrelated to any of the outcome measures. Muscle glycogen depletion was related to change in plasma IL-6 (r=0.462, P=0.040, with change in myoglobin related to plasma IL-8 (r=0.582, P=0.007 and plasma MCP-1 (r=0.457, P=0.043, and muscle MCP-1 protein (r=0.588, P=0.017; cortisol was related to plasma IL-8 (r=0.613, P=0.004, muscle IL-8 protein (r=0.681, P=0.004, and plasma MCP-1 (r=0.442, P=0.050. In summary, this study showed that muscle IL-6, IL-8, and MCP-1 mRNA expression after 75-km cycling was unrelated to glycogen depletion and muscle damage, with change in muscle glycogen related to plasma IL-6, and changes in serum myoglobin and cortisol related to the chemotactic cytokines IL-8 and MCP-1.

  4. Evaluation of Thin Plate Hydrodynamic Stability through a Combined Numerical Modeling and Experimental Effort

    Energy Technology Data Exchange (ETDEWEB)

    Tentner, A. [Argonne National Lab. (ANL), Argonne, IL (United States); Bojanowski, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Feldman, E. [Argonne National Lab. (ANL), Argonne, IL (United States); Wilson, E. [Argonne National Lab. (ANL), Argonne, IL (United States); Solbrekken, G [Univ. of Missouri, Columbia, MO (United States); Jesse, C. [Univ. of Missouri, Columbia, MO (United States); Kennedy, J. [Univ. of Missouri, Columbia, MO (United States); Rivers, J. [Univ. of Missouri, Columbia, MO (United States); Schnieders, G. [Univ. of Missouri, Columbia, MO (United States)

    2017-05-01

    An experimental and computational effort was undertaken in order to evaluate the capability of the fluid-structure interaction (FSI) simulation tools to describe the deflection of a Missouri University Research Reactor (MURR) fuel element plate redesigned for conversion to lowenriched uranium (LEU) fuel due to hydrodynamic forces. Experiments involving both flat plates and curved plates were conducted in a water flow test loop located at the University of Missouri (MU), at conditions and geometries that can be related to the MURR LEU fuel element. A wider channel gap on one side of the test plate, and a narrower on the other represent the differences that could be encountered in a MURR element due to allowed fabrication variability. The difference in the channel gaps leads to a pressure differential across the plate, leading to plate deflection. The induced plate deflection the pressure difference induces in the plate was measured at specified locations using a laser measurement technique. High fidelity 3-D simulations of the experiments were performed at MU using the computational fluid dynamics code STAR-CCM+ coupled with the structural mechanics code ABAQUS. Independent simulations of the experiments were performed at Argonne National Laboratory (ANL) using the STAR-CCM+ code and its built-in structural mechanics solver. The simulation results obtained at MU and ANL were compared with the corresponding measured plate deflections.

  5. Modeling the hydrodynamics of phloem sieve plates

    Directory of Open Access Journals (Sweden)

    Kaare Hartvig Jensen

    2012-07-01

    Full Text Available Sieve plates have an enormous impact on the efficiency of the phloem vascular system of plants, responsible for the distribution of photosynthetic products. These thin plates, which separate neighboring phloem cells, are perforated by a large number of tiny sieve pores and are believed to play a crucial role in protecting the phloem sap from intruding animals by blocking flow when the phloem cell is damaged. The resistance to the flow of viscous sap in the phloem vascular system is strongly affected by the presence of the sieve plates, but the hydrodynamics of the flow through them remains poorly understood. We propose a theoretical model for quantifying the effect of sieve plates on the phloem in the plant, thus unifying and improving previous work in the field. Numerical simulations of the flow in real and idealized phloem channels verify our model, and anatomical data from 19 plant species are investigated. We find that the sieve plate resistance is correlated to the cell lumen resistance, and that the sieve plate and the lumen contribute almost equally to the total hydraulic resistance of the phloem translocation pathway.

  6. p115 RhoGEF activates the Rac1 GTPase signaling cascade in MCP1 chemokine-induced vascular smooth muscle cell migration and proliferation.

    Science.gov (United States)

    Singh, Nikhlesh K; Janjanam, Jagadeesh; Rao, Gadiparthi N

    2017-08-25

    Although the involvement of Rho proteins in the pathogenesis of vascular diseases is well studied, little is known about the role of their upstream regulators, the Rho guanine nucleotide exchange factors (RhoGEFs). Here, we sought to identify the RhoGEFs involved in monocyte chemotactic protein 1 (MCP1)-induced vascular wall remodeling. We found that, among the RhoGEFs tested, MCP1 induced tyrosine phosphorylation of p115 RhoGEF but not of PDZ RhoGEF or leukemia-associated RhoGEF in human aortic smooth muscle cells (HASMCs). Moreover, p115 RhoGEF inhibition suppressed MCP1-induced HASMC migration and proliferation. Consistent with these observations, balloon injury (BI) induced p115 RhoGEF tyrosine phosphorylation in rat common carotid arteries, and siRNA-mediated down-regulation of its levels substantially attenuated BI-induced smooth muscle cell migration and proliferation, resulting in reduced neointima formation. Furthermore, depletion of p115 RhoGEF levels also abrogated MCP1- or BI-induced Rac1-NFATc1-cyclin D1-CDK6-PKN1-CDK4-PAK1 signaling, which, as we reported previously, is involved in vascular wall remodeling. Our findings also show that protein kinase N1 (PKN1) downstream of Rac1-cyclin D1/CDK6 and upstream of CDK4-PAK1 in the p115 RhoGEF-Rac1-NFATc1-cyclin D1-CDK6-PKN1-CDK4-PAK1 signaling axis is involved in the modulation of vascular wall remodeling. Of note, we also observed that CCR2-G i/o -Fyn signaling mediates MCP1-induced p115 RhoGEF and Rac1 GTPase activation. These findings suggest that p115 RhoGEF is critical for MCP1-induced HASMC migration and proliferation in vitro and for injury-induced neointima formation in vivo by modulating Rac1-NFATc1-cyclin D1-CDK6-PKN1-CDK4-PAK1 signaling. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.

  7. AOPPs Induce MCP-1 Expression by Increasing ROS-Mediated Activation of the NF-κB Pathway in Rat Mesangial Cells: Inhibition by Sesquiterpene Lactones

    Directory of Open Access Journals (Sweden)

    Jian-Cheng Wang

    2013-12-01

    Full Text Available Background: Monocyte chemoattractant protein-1 (MCP-1 plays an important role in extracellular matrix accumulation through macrophage recruitment and activation in the development and progression of diabetic nephropathy. Therefore, this study examined whether advanced oxidation protein products (AOPPs are involved in nuclear factor-κB (NF-κB activation and MCP-1 mRNA and protein expression in mesangial cells (MCs and evaluated the effects of derivatives of sesquiterpene lactones (SLs on AOPP-induced renal damage. Methods: MCP-1 mRNA and protein expression in MCs were determined by quantitative real-time PCR and ELISA, respectively. The level of intracellular reactive oxygen species (ROS was determined by flow cytometry. The protein expression of tubulin, P47, NF-κB p65, phospho-NF-κB p65, IκB, phospho-IκB, IKKß and phospho-IKKß was evaluated by Western blot. Results: AOPPs caused oxidative stress in MCs and activated the NF-κB pathway by inducing IκBa phosphorylation and degradation. Inhibition of ROS by SOD (ROS inhibitor blocked the AOPP-mediated NF-κB pathway. Moreover, the inhibition of AOPP-induced overproduction of MCP-1 mRNA and protein was associated with inhibition of IκBa degradation by SLs. Conclusion: AOPPs induce MCP-1 expression by activating the ROS/NF-κB pathway and can be inhibited by SLs. These findings may provide a novel approach to treat inflammatory and immune renal diseases, including diabetic nephropathy.

  8. Fabrication of carbon-polymer composite bipolar plates for polymer electrolyte membrane fuel cells by compression moulding

    International Nuclear Information System (INIS)

    Raza, M.A.; Ahmed, R.; Saleem, A.; Din, R.U.

    2009-01-01

    Fuel cells are considered as one of the most important technologies to address the future energy and environmental pollution problems. These are the most promising power sources for road transportation and portable devices. A fuel cell is an electrochemical device that converts chemical energy into electrical energy. A fuel cell stack consists of bipolar plates and membrane electrode assemblies (MEA). The bipolar plate is by weight, volume and cost one of the most significant components of a fuel cell stack. Major functions of bipolar plates are to separate oxidant and fuel gas, provide flow channels, conduct electricity and provide heat transfer. Bipolar plates can be made from various materials including graphite, metals, carbon / carbon and carbon/ polymer composites. Materials for carbon-polymer composites are relatively inexpensive, less corrosive, strong and channels can be formed by means of a moulding process. Carbon-polymer composites are of two type i.e; thermosetting and thermoplastic. For thermosetting composite a bulk molding compound (BMC) was prepared by adding graphite, vinyl ester resin, methyl ethyl ketone peroxide and cobalt naphthalate. The BMC was thoroughly mixed, poured into a die mould of a bipolar plate with channels and hot pressed at a specific temperature and pressure. A bipolar plate was formed according to the die mould. Design of the mould is also discussed. Conducting polymers were also added to BMC to increase the conductivity of bipolar plates. Particle size of the graphite has also a significant effect on the conductivity of the bipolar plates. Thermoplastic composites were also prepared using polypropylene and graphite.

  9. The influence of flow maldistribution on the performance of inhomogeneous parallel plate heat exhangers

    DEFF Research Database (Denmark)

    Nielsen, Kaspar Kirstein; Engelbrecht, Kurt; Bahl, Christian R.H.

    2013-01-01

    of 50 random stacks having equal average channel thicknesses with 20 channels each are used to provide a statistical base. The standard deviation of the stacks is varied as are the flow rate (Reynolds number) and the thermal conductivity of the solid heat exchanger material. It is found that the heat...... transfer performance of inhomogeneous stacks of parallel plates may be reduced significantly due to the maldistribution of the fluid flow compared to the ideal homogeneous case. The individual channels experience different flow velocities and this further induces an inter-channel thermal cross talk.......The heat transfer performance of inhomogeneous parallel plate heat exchangers in transient operation is investigated using an established model. A performance parameter, denoted the Nusselt-scaling factor, is used as benchmark and calculated using a well-established single blow technique. A sample...

  10. Circular arc fuel plate stability experiments and analyses for the advanced neutron source

    International Nuclear Information System (INIS)

    Swinson, W.F.; Battiste, R.L.; Yahr, G.T.

    1995-08-01

    The thin fuel plates planned for the Advanced Neutron Source are to be cooled by forcing heavy water at high velocity, 25 m/s, through thin cooling channels on each side of each plate. Because the potential for structural failure of the plates is a design concern, considerable effort has been expended in assessing this potential. As part of this effort, experimental flow tests and analyses to evaluate the structural response of circular arc plates have been conducted, and the results are given in this report

  11. Imaging microchannel plate detectors for XUV sky survey experiments

    International Nuclear Information System (INIS)

    Barstow, M.A.; Fraser, G.W.; Milward, S.R.

    1986-01-01

    Attention is given to the development of microchannel plate detectors for the Wide Field Camera (WFC) XUV (50-300 A) sky survey experiment on Rosat. A novel feature of the detector design is that the microchannel plates and their resistive anode readout are curved to the same radius as the WFC telescope focal surface. It is shown that curving the channel plates is not detrimental to gain uniformity. The paper describes the design of a curved resistive anode readout element and contrasts the present measurements of spatial resolution, global and local uniformity and temperature coefficient of resistance with the poor performance recently ascribed to resistive anodes in the literature. 18 references

  12. A broad-application microchannel-plate detector system for advanced particle or photon detection tasks large area imaging, precise multi-hit timing information and high detection rate

    CERN Document Server

    Jagutzki, O; Mergel, V; Schmidt-Böcking, H; Spielberger, L; Spillmann, U; Ullmann-Pfleger, K

    2002-01-01

    New applications for single particle and photon detection in many fields require both large area imaging performance and precise time information on each detected particle. Moreover, a very high data acquisition rate is desirable for most applications and eventually the detection and imaging of more than one particle arriving within a microsecond is required. Commercial CCD systems lack the timing information whereas other electronic microchannel plate (MCP) read-out schemes usually suffer from a low acquisition rate and complicated and sometimes costly read-out electronics. We have designed and tested a complete imaging system consisting of an MCP position readout with helical wire delay-lines, single-unit amplifier box and PC-controlled time-to-digital converter (TDC) readout. The system is very flexible and can detect and analyse position and timing information at single particle rates beyond 1 MHz. Alternatively, multi-hit events can be collected and analysed at about 20 kHz rate. We discuss the advantage...

  13. Microchannel plate detector technology potential for LUVOIR and HabEx

    Science.gov (United States)

    Siegmund, O. H. W.; Ertley, C.; Vallerga, J. V.; Schindhelm, E. R.; Harwit, A.; Fleming, B. T.; France, K. C.; Green, J. C.; McCandliss, S. R.; Harris, W. M.

    2017-08-01

    Microchannel plate (MCP) detectors have been the detector of choice for ultraviolet (UV) instruments onboard many NASA missions. These detectors have many advantages, including high spatial resolution (hardness, large formats (up to 20 cm), and ability for curved focal plane matching. Novel borosilicate glass MCPs with atomic layer deposition combine extremely low backgrounds, high strength, and tunable secondary electron yield. GaN and combinations of bialkali/alkali halide photocathodes show promise for broadband, higher quantum efficiency. Cross-strip anodes combined with compact ASIC readout electronics enable high spatial resolution over large formats with high dynamic range. The technology readiness levels of these technologies are each being advanced through research grants for laboratory testing and rocket flights. Combining these capabilities would be ideal for UV instruments onboard the Large UV/Optical/IR Surveyor (LUVOIR) and the Habitable Exoplanet Imaging Mission (HABEX) concepts currently under study for NASA's Astrophysics Decadal Survey.

  14. Measurement of photomultiplier effective quantum efficiency

    International Nuclear Information System (INIS)

    Arshad, S.; Gowers, C.; Nielsen, P.

    1998-07-01

    The JET divertor LIDAR system, is being modified to perform measurements of plasma edge electron temperature and density in the new gas-box divertor configuration. The change involves raising the line of sight from the divertor region so that the laser beam passes through the plasma edge reaching a depth of ∼ 5 cm inside the boundary. Changes are also being made to the detection system. This currently employs a grating, spectrometer and a streak camera. The new system will contain a 4-channel filter spectrometer with microchannel plate (MCP) photomuItipliers

  15. Increased cerebrospinal fluid levels of cytokines monocyte chemoattractant protein-1 (MCP-1) and macrophage inflammatory protein-1β (MIP-1β) in patients with amyotrophic lateral sclerosis.

    Science.gov (United States)

    Martínez, H R; Escamilla-Ocañas, C E; Camara-Lemarroy, C R; González-Garza, M T; Moreno-Cuevas, J; García Sarreón, M A

    2017-10-10

    Neuroinflammation has recently been described in amyotrophic lateral sclerosis (ALS). However, the precise role of such proinflammatory cytokines as monocyte chemoattractant protein-1 (MCP-1) and macrophage inflammatory protein-1β (MIP-1β) in ALS has not yet been determined. In this study, we determined cerebrospinal fluid (CSF) MCP-1 and MIP-1β levels and assessed their association with the duration and severity of ALS. Concentrations of MCP-1 and MIP-1β were determined in the CSF of 77 patients diagnosed with ALS and 13 controls. Cytokine levels were analysed in relation to ALS duration (12months) and severity (30points on the ALS Functional Rating Scale administered at hospital admission). Higher CSF MIP-1β (10.68pg/mL vs. 4.69pg/mL, P<.0001) and MCP-1 (234.89pg/mL vs. 160.95pg/mL, P=.011) levels were found in the 77 patients with ALS compared to controls. There were no differences in levels of either cytokine in relation to disease duration or severity. However, we did observe a significant positive correlation between MIP-1β and MCP-1 in patients with ALS. The increase in MIP-1β and MCP-1 levels suggests that these cytokines may have a synergistic effect on ALS pathogenesis. However, in our cohort, no association was found with either the duration or the clinical severity of the disease. Copyright © 2017 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Three-dimensional particle-in-cell simulation on gain saturation effect of microchannel plate

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Qiangqiang; Yuan, Zheng; Cao, Zhurong, E-mail: cao33jin@aliyun.com; Deng, Bo; Chen, Tao; Deng, Keli [Research Center of Laser Fusion, Chinese Academy of Engineering Physics, Mianyang, Sichuan 621900 (China)

    2016-07-15

    We present here the results of the simulation work, using the three-dimensional particle-in-cell method, on the performance of the lead glass microchannel plate under saturated state. We calculated the electron cascade process with different DC bias voltages under both self-consistent condition and non-self-consistent condition. The comparative results have demonstrated that the strong self-consistent field can suppress the cascade process and make the microchannel plate saturated. The simulation results were also compared to the experimental data and good agreement was obtained. The simulation results also show that the electron multiplication process in the channel is accompanied by the buildup process of positive charges in the channel wall. Though the interactions among the secondary electron cloud in the channel, the positive charges in the channel wall, and the external acceleration field can make the electron-surface collision more frequent, the collision energy will be inevitably reduced, thus the electron gain will also be reduced.

  17. Effects of postharvest application of 1-MCP and postcutting dip treatment on the quality and nutritional properties of fresh-cut kiwifruit.

    Science.gov (United States)

    Antunes, Maria D C; Dandlen, Susana; Cavaco, Ana M; Miguel, Graça

    2010-05-26

    Consumption of minimally processed fruit and vegetables has increased significantly in the past few years due to the consumers' life style. The aim of this study was to evaluate the effect of treatment with ascorbic acid or calcium chloride on the quality parameters of fresh-cut kiwifruit prepared from fruit previously stored for 3 months, either treated or not treated with 1-methylcyclopropene (1-MCP) before storage. Harvested fruit were treated with 1 microL L(-1) 1-MCP for 20 h at room temperature ( approximately 20 degrees C) (MCP) or had no treatment (C) and were then stored at 0 degrees C. After 3 months, fruit were removed from storage, peeled, and cut longitudinally in quarters, dipped in 2% ascorbic acid (Asc), 2% calcium chloride (Ca), or just water (cont), and kept at 2 degrees C for 8 days. Measurements of firmness, soluble solids content (SSC) ( degrees Brix), color (CIE L*, a*, b*), electrolyte leakage, sugars, organic acids, total phenolics, and antioxidant activity (DPPH and ABTS) were performed at 0, 4, and 8 days. A taste panel was performed on the seventh shelf life day. It was shown that whole MCP-treated kiwifruit kept better than the control through the 3 months storage, this effect being lost through the fresh-cut shelf life period. Furthermore, the postcut dip on 2% CaCl(2) was effective on delaying softening and browning of fresh-cut kiwifruit, which were also the fruit preferred by panelists. Both ascorbic acid and CaCl(2) were effective on preserving or improving nutritional properties (phenolics, ascorbic acid, DPPH, and ABTS) mainly in the first 4 days of shelf life. The CaCl(2) had a further beneficial effect until 8 shelf life days. It is suggested that CaCl(2) is better in keeping overall quality through 8 days of shelf life at 2 degrees C in fresh-cut kiwifruit followed by Asc, and 1-MCP has negligible effect in the conditions of this experiment.

  18. EFECTO DEL 1-METILCICLOPROPENO (1-MCP SOBRE LA FISIOLOGÍA Y CALIDAD DE FRUTOS DE JACA (Artocarpus heterophyllus Lam.

    Directory of Open Access Journals (Sweden)

    M. Mata-Montes de Oca

    2007-01-01

    Full Text Available Debido a sus características de color y sabor de pulpa, la demanda de fruta de jaca se ha incrementado considerablemente. La mayoría de la producción de Nayarit es exportada a los Estados Unidos de Norteamérica. Sin embargo, debido a su corta vida de anaquel y susceptibilidad al daño por frío la fruta es exportada vía aérea con altos costos de flete. Se reporta que el 1-Metilciclopropeno (1-MCP retarda el proceso de madurez, alarga la vida de anaquel y mantiene la calidad de varios frutales, así que el objetivo de este estudio fue evaluar el efecto del 1-MCP sobre la fisiología y calidad del fruto de jaca almacenado a 20 ºC. Las frutas fueron cosechadas en madurez fisiológica, lavadas y tratadas con 1-MCP a 100 y 300 nl·litro-1 en cámaras selladas por 12 h a 20 ± 1 ºC; 85 ± 5 % de HR manteniendo un testigo sin tratar. Las variables evaluadas fueron: velocidad de respiración y de producción de etileno, sólidos solubles totales, acidez titulable, firmeza de la pulpa y de la fruta entera, color en la pulpa y pérdida de peso. El 1-MCP no afectó la mayoría de las variables de calidad pero retrasó significativamente la velocidad de respiración y la producción de etileno así como el ablandamiento de la pulpa, lo que permitió prolongar la vida de anaquel hasta por ocho y 12 días a 100 y 300 nl·litro-1, respectivamente.

  19. Coordinate-sensitive charged particle detector for spectroscopy

    Directory of Open Access Journals (Sweden)

    Sidorenko V. P.

    2016-10-01

    Full Text Available The authors have designed, manufactured and tested a coordinate-sensitive detector for charged particle spectroscopy. The detector can be used in the devices for the elemental analysis of materials, providing simultaneous analysis of all the elemental composition with high sensitivity and precision. The designed device is based on an integrated circuit (IC and a microchannel plate (MCP electron multiplier. The IC is mounted on a ceramic substrate. Ions fall on the MCP mounted above the IC. Giving rise to a pulse which typically exceeds 106 electrons, each ion falls on the detector electrodes and these pulses are counted. In this research, a two stage stack of MCPs (Hamamatsu was used. The MCPs have a channel diameter of 12 μm on a 15 μm pitch. The results of tests carried out in a mass spectrometer are presented. The designed detector is small, light, and low-power.

  20. Fast microchannel plate detector for particles

    International Nuclear Information System (INIS)

    Wurz, P.; Gubler, L.

    1996-01-01

    In this article we report on the timing capabilities of a new microchannel plate detector we designed and built. The detector assembly has an impedance-matched transition line (50 Ω line resistance) from anode to cable connector which is considerably smaller than other, commercially available solutions and at the same time has about four times the active area. The detector was tested with an alpha particle source and excellent time response was achieved. Using 10 μm pore size channel plates, a rise time of 300 ps and a pulse width of 520 ps are obtained. The details of the signal analysis are also given in the article. copyright 1996 American Institute of Physics

  1. Comparative evaluation of three heat transfer enhancement strategies in a grooved channel

    Energy Technology Data Exchange (ETDEWEB)

    Herman, C.; Kang, E. [Dept. of Mechanical Engineering, Johns Hopkins Univ., Baltimore, MD (United States)

    2001-09-01

    Results of a comparative evaluation of three heat transfer enhancement strategies for forced convection cooling of a parallel plate channel populated with heated blocks, representing electronic components mounted on printed circuit boards, are reported. Heat transfer in the reference geometry, the asymmetrically heated parallel plate channel, is compared with that for the basic grooved channel, and the same geometry enhanced by cylinders and vanes placed above the downstream edge of each heated block. In addition to conventional heat transfer and pressure drop measurements, holographic interferometry combined with high-speed cinematography was used to visualize the unsteady temperature fields in the self-sustained oscillatory flow. The locations of increased heat transfer within one channel periodicity depend on the enhancement technique applied, and were identified by analyzing the unsteady temperature distributions visualized by holographic interferometry. This approach allowed gaining insight into the mechanisms responsible for heat transfer enhancement. Experiments were conducted at moderate flow velocities in the laminar, transitional and turbulent flow regimes. Reynolds numbers were varied in the range Re = 200-6500, corresponding to flow velocities from 0.076 to 2.36 m/s. Flow oscillations were first observed between Re = 1050 and 1320 for the basic grooved channel, and around Re = 350 and 450 for the grooved channels equipped with cylinders and vanes, respectively. At Reynolds numbers above the onset of oscillations and in the transitional flow regime, heat transfer rates in the investigated grooved channels exceeded the performance of the reference geometry, the asymmetrically heated parallel plate channel. Heat transfer in the grooved channels enhanced with cylinders and vanes showed an increase by a factor of 1.2-1.8 and 1.5-3.5, respectively, when compared to data obtained for the basic grooved channel; however, the accompanying pressure drop penalties

  2. Rhizoma coptidis Inhibits LPS-Induced MCP-1/CCL2 Production in Murine Macrophages via an AP-1 and NFB-Dependent Pathway

    Directory of Open Access Journals (Sweden)

    Andrew Remppis

    2010-01-01

    Full Text Available Introduction. The Chinese extract Rhizoma coptidis is well known for its anti-inflammatory, antioxidative, antiviral, and antimicrobial activity. The exact mechanisms of action are not fully understood. Methods. We examined the effect of the extract and its main compound, berberine, on LPS-induced inflammatory activity in a murine macrophage cell line. RAW 264.7 cells were stimulated with LPS and incubated with either Rhizoma coptidis extract or berberine. Activation of AP-1 and NFB was analyzed in nuclear extracts, secretion of MCP-1/CCL2 was measured in supernatants. Results. Incubation with Rhizoma coptidis and berberine strongly inhibited LPS-induced monocyte chemoattractant protein (MCP-1 production in RAW cells. Activation of the transcription factors AP-1 and NFB was inhibited by Rhizoma coptidis in a dose- and time-dependent fashion. Conclusions. Rhizoma coptidis extract inhibits LPS-induced MCP-1/CCL2 production in vitro via an AP-1 and NFB-dependent pathway. Anti-inflammatory action of the extract is mediated mainly by its alkaloid compound berberine.

  3. Natural convection enhancement by a discrete vibrating plate and a cross-flow opening: a numerical investigation

    Science.gov (United States)

    Florio, L. A.; Harnoy, A.

    2011-06-01

    In this study, a unique combination of a vibrating plate and a cross-flow passage is proposed as a means of enhancing natural convection cooling. The enhancement potential was estimated based on numerical studies involving a representative model which includes a short, transversely oscillating plate, placed over a transverse cross-flow opening in a uniformly heated vertical channel wall dividing two adjacent vertical channels. The resulting velocity and temperature fields are analyzed, with the focus on the local thermal effects near the opening. The simulation indicates up to a 50% enhancement in the local heat transfer coefficient for vibrating plate amplitudes of at least 30% of the mean clearance space and frequencies of over 82 rad/s.

  4. Detector Physics of Resistive Plate Chambers

    CERN Document Server

    Lippmann, Christian; Riegler, W

    2003-01-01

    Resistive Plate Chambers (RPCs) are gaseous parallel plate avalanche detectors that implement electrodes made from a material with a high volume resistivity between 10^7 and 10^12 Ohm cm. Large area RPCs with 2mm single gaps operated in avalanche mode provide above 98% efficiency and a time resolution of around 1ns up to a flux of several kHz/cm2. These Trigger RPCs will, as an example, equip the muon detector system of the ATLAS experiment at CERN on an area of 3650m2 and with 355.000 independent read out channels. Timing RPCs with a gas gap of 0.2 to 0.3mm are widely used in multi gap configurations and provide 99% efficiency and time resolution down to 50ps. While their performance is comparable to existing scintillator-based Time-Of-Flight (TOF) technology, Timing RPCs feature a significantly, up to an order of magnitude, lower price per channel. They will for example equip the 176m2 TOF barrel of the ALICE experiment at CERN with 160.000 independent read out cells. RPCs were originally operated in stream...

  5. Determination of transfer parameters in corrugated plates exchangers

    International Nuclear Information System (INIS)

    Silva Lima Filho, S. da.

    1984-01-01

    In this work is presented a experimental study about the forced convenction problem in vee-corrugated exchangers, with flow in the transversal sense, and parallel plates exchangers in which the isotermal plate is equivalent to the absobing one and the other plate is adiabatic. Global values of the transfer coefficients were experimentally obtained by application of the Naphthalene Sublimation Technique in accordance with the analogy between heat and mass transfer. The results were expressed in terms of Sh sup(-) /Sc sup(0,4) that according to the analogy is equal the Nu sup(-) / Pr sup(0,4) in function of the Reynolds number. The ratio between the lenght of the channel and the average spacing between plates L/2a was ranged in all the exchangers. Parameters of transfer to angles of 45 0 and 31 0 were determined in the corrugated plates exchangers. The experimental results obtained were analyzed and compared among them. Finally practical applications of these results are presented to heat exchangers with similars geometric characteristics. (Author) [pt

  6. Dynamic Characterizations of an 8-frame, Half-Strip, High-speed X-ray Microchannel Plate Imager

    International Nuclear Information System (INIS)

    Ken Moy; Ming Wu; Craig Kruschwitz; Aric Tibbits; Matt Griffin; Greg Rochau

    2008-01-01

    High-speed microchannel plate (MCP)-based imagers are critical detectors for x-ray diagnostics employed on Z-experiments at Sandia National Laboratories (SNL) to measure time-resolved x-ray spectra and to image dynamic hohlraums. A multiframe design using eight half strips in one imager permits recordings of radiation events in discrete temporal snapshots to yield a time-evolved movie. We present data using various facilities to characterize the performance of this design. These characterization studies include DC and pulsed-voltage biased measurements in both saturated and linear operational regimes using an intense, short-pulsed UV laser. Electrical probe measurements taken to characterize the shape of the HV pulse propagating across the strips help to corroborate the spatial gain dependence

  7. The Effect of Post-Resistance Exercise Amino Acids on Plasma MCP-1 and CCR2 Expression

    Directory of Open Access Journals (Sweden)

    Adam J. Wells

    2016-07-01

    Full Text Available The recruitment and infiltration of classical monocytes into damaged muscle is critical for optimal tissue remodeling. This study examined the effects of an amino acid supplement on classical monocyte recruitment following an acute bout of lower body resistance exercise. Ten resistance-trained men (24.7 ± 3.4 years; 90.1 ± 11.3 kg; 176.0 ± 4.9 cm ingested supplement (SUPP or placebo (PL immediately post-exercise in a randomized, cross-over design. Blood samples were obtained at baseline (BL, immediately (IP, 30-min (30P, 1-h (1H, 2-h (2H, and 5-h (5H post-exercise to assess plasma concentrations of monocyte chemoattractant protein 1 (MCP-1, myoglobin, cortisol and insulin concentrations; and expressions of C-C chemokine receptor-2 (CCR2, and macrophage-1 antigen (CD11b on classical monocytes. Magnitude-based inferences were used to provide inferences on the true effects of SUPP compared to PL. Changes in myoglobin, cortisol, and insulin concentrations were similar between treatments. Compared to PL, plasma MCP-1 was “very likely greater” (98.1% likelihood effect in SUPP at 2H. CCR2 expression was “likely greater” at IP (84.9% likelihood effect, “likely greater” at 1H (87.7% likelihood effect, “very likely greater” at 2H (97.0% likelihood effect, and “likely greater” at 5H (90.1% likelihood effect in SUPP, compared to PL. Ingestion of SUPP did not influence CD11b expression. Ingestion of an amino acid supplement immediately post-exercise appears to help maintain plasma MCP-1 concentrations and augment CCR2 expression in resistance trained men.

  8. The host response to the probiotic Escherichia coli strain Nissle 1917: Specific up-regulation of the proinflammatory chemokine MCP-1

    Directory of Open Access Journals (Sweden)

    Ukena Sya N

    2005-12-01

    Full Text Available Abstract Background The use of live microorganisms to influence positively the course of intestinal disorders such as infectious diarrhea or chronic inflammatory conditions has recently gained increasing interest as a therapeutic alternative. In vitro and in vivo investigations have demonstrated that probiotic-host eukaryotic cell interactions evoke a large number of responses potentially responsible for the effects of probiotics. The aim of this study was to improve our understanding of the E. coli Nissle 1917-host interaction by analyzing the gene expression pattern initiated by this probiotic in human intestinal epithelial cells. Methods Gene expression profiles of Caco-2 cells treated with E. coli Nissle 1917 were analyzed with microarrays. A second human intestinal cell line and also pieces of small intestine from BALB/c mice were used to confirm regulatory data of selected genes by real-time RT-PCR and cytometric bead array (CBA to detect secretion of corresponding proteins. Results Whole genome expression analysis revealed 126 genes specifically regulated after treatment of confluent Caco-2 cells with E. coli Nissle 1917. Among others, expression of genes encoding the proinflammatory molecules monocyte chemoattractant protein-1 ligand 2 (MCP-1, macrophage inflammatory protein-2 alpha (MIP-2α and macrophage inflammatory protein-2 beta (MIP-2β was increased up to 10 fold. Caco-2 cells cocultured with E. coli Nissle 1917 also secreted high amounts of MCP-1 protein. Elevated levels of MCP-1 and MIP-2α mRNA could be confirmed with Lovo cells. MCP-1 gene expression was also up-regulated in mouse intestinal tissue. Conclusion Thus, probiotic E. coli Nissle 1917 specifically upregulates expression of proinflammatory genes and proteins in human and mouse intestinal epithelial cells.

  9. Rhizoma Coptidis Inhibits LPS-Induced MCP-1/CCL2 Production in Murine Macrophages via an AP-1 and NFκB-Dependent Pathway

    Science.gov (United States)

    Remppis, Andrew; Bea, Florian; Greten, Henry Johannes; Buttler, Annette; Wang, Hongjie; Zhou, Qianxing; Preusch, Michael R.; Enk, Ronny; Ehehalt, Robert; Katus, Hugo; Blessing, Erwin

    2010-01-01

    Introduction. The Chinese extract Rhizoma coptidis is well known for its anti-inflammatory, antioxidative, antiviral, and antimicrobial activity. The exact mechanisms of action are not fully understood. Methods. We examined the effect of the extract and its main compound, berberine, on LPS-induced inflammatory activity in a murine macrophage cell line. RAW 264.7 cells were stimulated with LPS and incubated with either Rhizoma coptidis extract or berberine. Activation of AP-1 and NFκB was analyzed in nuclear extracts, secretion of MCP-1/CCL2 was measured in supernatants. Results. Incubation with Rhizoma coptidis and berberine strongly inhibited LPS-induced monocyte chemoattractant protein (MCP)-1 production in RAW cells. Activation of the transcription factors AP-1 and NFκB was inhibited by Rhizoma coptidis in a dose- and time-dependent fashion. Conclusions. Rhizoma coptidis extract inhibits LPS-induced MCP-1/CCL2 production in vitro via an AP-1 and NFκB-dependent pathway. Anti-inflammatory action of the extract is mediated mainly by its alkaloid compound berberine. PMID:20652055

  10. Laminated exfoliated graphite composite-metal compositions for fuel cell flow field plate or bipolar plate applications

    Science.gov (United States)

    Zhamu, Aruna; Shi, Jinjun; Guo, Jiusheng; Jang, Bor Z

    2014-05-20

    An electrically conductive laminate composition for fuel cell flow field plate or bipolar plate applications. The laminate composition comprises at least a thin metal sheet having two opposed exterior surfaces and a first exfoliated graphite composite sheet bonded to the first of the two exterior surfaces of the metal sheet wherein the exfoliated graphite composite sheet comprises: (a) expanded or exfoliated graphite and (b) a binder or matrix material to bond the expanded graphite for forming a cohered sheet, wherein the binder or matrix material is between 3% and 60% by weight based on the total weight of the first exfoliated graphite composite sheet. Preferably, the first exfoliated graphite composite sheet further comprises particles of non-expandable graphite or carbon in the amount of between 3% and 60% by weight based on the total weight of the non-expandable particles and the expanded graphite. Further preferably, the laminate comprises a second exfoliated graphite composite sheet bonded to the second surface of the metal sheet to form a three-layer laminate. Surface flow channels and other desired geometric features can be built onto the exterior surfaces of the laminate to form a flow field plate or bipolar plate. The resulting laminate has an exceptionally high thickness-direction conductivity and excellent resistance to gas permeation.

  11. Binary zone-plate array for a parallel joint transform correlator applied to face recognition.

    Science.gov (United States)

    Kodate, K; Hashimoto, A; Thapliya, R

    1999-05-10

    Taking advantage of small aberrations, high efficiency, and compactness, we developed a new, to our knowledge, design procedure for a binary zone-plate array (BZPA) and applied it to a parallel joint transform correlator for the recognition of the human face. Pairs of reference and unknown images of faces are displayed on a liquid-crystal spatial light modulator (SLM), Fourier transformed by the BZPA, intensity recorded on an optically addressable SLM, and inversely Fourier transformed to obtain correlation signals. Consideration of the bandwidth allows the relations among the channel number, the numerical aperture of the zone plates, and the pattern size to be determined. Experimentally a five-channel parallel correlator was implemented and tested successfully with a 100-person database. The design and the fabrication of a 20-channel BZPA for phonetic character recognition are also included.

  12. Prokaryotic expression and in vitro functional analysis of IL-1β and MCP-1 from guinea pig.

    Science.gov (United States)

    Dirisala, Vijaya R; Jeevan, Amminikutty; Ly, Lan H; McMurray, David N

    2013-06-01

    The Guinea pig (Cavia porcellus) is an excellent animal model for studying human tuberculosis (TB) and also for a number of other infectious and non-infectious diseases. One of the major roadblocks in effective utilization of this animal model is the lack of readily available immunological reagents. In order to address this issue, guinea pig interleukin 1 beta (IL-1β) and monocyte chemoattractant protein-1 (MCP-1) were efficiently cloned and expressed in a prokaryotic expression vector, and the expressed proteins in soluble form from both the genes were confirmed by N-terminal sequencing. The biological activity of recombinant guinea pig IL-1β was demonstrated by its ability to drive proliferation in thymocytes, and the recombinant guinea pig MCP-1 exhibited chemotactic activity for guinea pig resident peritoneal macrophages. These biologically active recombinant guinea pig proteins will facilitate an in-depth understanding of the role they play in the immune responses of the guinea pig to TB and other diseases.

  13. Chemical reaction in MHD flow past a vertical plate with mass ...

    African Journals Online (AJOL)

    flow in a vertical double passage channel using Robin boundary conditions. ... the diffusion of a chemically reactive species in a laminar boundary layer flow. ...... hydrodynamic flow past a flat plate will Hall effects, Journal of the Physical.

  14. Enhance heat transfer in the channel with V-shaped wavy lower plate using liquid nanofluids

    Directory of Open Access Journals (Sweden)

    Azher M. Abed

    2015-03-01

    Full Text Available The heat transfer and flow characteristics in corrugated with V-shape lower plate using nanofluids are numerically studied. The computations are performed on uniform heat flux over a range of Reynolds number (Re 8000–20,000. The governing equations are numerically solved in the domain by a finite volume method (FVM using the k–ε standard turbulent model. Studies are carried out for different types of nanoparticles Al2O3,CuO, SiO2 and ZnO with different volume fractions in the range of 0–4%. Three different types of base fluid (water, glycerin, ethylene glycol are also examined. Results indicated that the average Nusselt number for nanofluids is greater than that of the base liquid. The SiO2 nanofluid yields the best heat transfer enhancement among all other type of nanofluids. Heat transfer enhancement increase with increases the volumetric concentration, but it is accompanied by increasing pressure drop values. Moreover, the average Nusselt number increases with an increase in Reynolds number and volume concentration. The SiO2–glycerin nanofluid has the highest Nusselt number compared with other base fluids. The present study shows that these V-shaped wavy channels have advantages by using nanofluids and thus serve as promising candidates for incorporation into efficient heat transfer devices.

  15. Manufacturing experiment on a cooling plate for a blanket breeder unit

    International Nuclear Information System (INIS)

    Weth, A. von der; Aktaa, J.

    2008-01-01

    Plates with curved cooling channels will be used as structural elements in a breeding blanket of a future fusion power plant. Such power plants are a promising attempt for future electrical energy production. The central manufacturing process of such cooling plates is a diffusion welding process. Such a process has been 'available' on a laboratory scale for years. But this diffusion welding process has not yet been applied on an industrial scale. This contribution documents our first attempt to transfer this to industry, a so-called uniaxial diffusion welding setup. The industrial transfer was attempted in two steps: (1) On a small cooling plate mock-up and (2) On a true-scale cooling plate. The problems with the technical transfer of the diffusion welding process from the laboratory scale to the true scale were outlined

  16. MicroCameras and Photometers (MCP) on board the TARANIS satellite

    Science.gov (United States)

    Farges, T.; Hébert, P.; Le Mer-Dachard, F.; Ravel, K.; Gaillac, S.

    2017-12-01

    TARANIS (Tool for the Analysis of Radiations from lightNing and Sprites) is a CNES micro satellite. Its main objective is to study impulsive transfers of energy between the Earth atmosphere and the space environment. It will be sun-synchronous at an altitude of 700 km. It will be launched in 2019 for at least 2 years. Its payload is composed of several electromagnetic instruments in different wavelengths (from gamma-rays to radio waves including optical). TARANIS instruments are currently in calibration and qualification phase. The purpose is to present the MicroCameras and Photometers (MCP) design, to show its performances after its recent characterization and at last to discuss the scientific objectives and how we want to answer it with the MCP observations. The MicroCameras, developed by Sodern, are dedicated to the spatial description of TLEs and their parent lightning. They are able to differentiate sprite and lightning thanks to two narrow bands ([757-767 nm] and [772-782 nm]) that provide simultaneous pairs of images of an Event. Simulation results of the differentiation method will be shown. After calibration and tests, the MicroCameras are now delivered to the CNES for integration on the payload. The Photometers, developed by Bertin Technologies, will provide temporal measurements and spectral characteristics of TLEs and lightning. There are key instrument because of their capability to detect on-board TLEs and then switch all the instruments of the scientific payload in their high resolution acquisition mode. Photometers use four spectral bands in the [170-260 nm], [332-342 nm], [757-767 nm] and [600-900 nm] and have the same field of view as cameras. The on-board TLE detection algorithm remote-controlled parameters have been tuned before launch using the electronic board and simulated or real events waveforms. After calibration, the Photometers are now going through the environmental tests. They will be delivered to the CNES for integration on the

  17. Prediction for the flow distribution and the pressure drop of a plate type fuel assembly

    International Nuclear Information System (INIS)

    Park, Jong Hark; Jo, Dea Sung; Chae, Hee Taek; Lee, Byung Chul

    2011-01-01

    A plate type fuel assembly widely used in many research reactors does not allow the coolant to mix with neighboring fuel channels due to the completely separated flow channels. If there is a serious inequality of coolant distribution among channels, it can reduce thermal-hydraulic safety margin, as well as it can cause a deformation of fuel plates by the pressure difference between neighboring channels, thus the flow uniformity in the fuel assembly should be confirmed. When designing a primary cooling system (PCS), the pressure drop through a reactor core is a dominant value to determine the PCS pump size. The major portion of reactor core pressure drop is caused by the fuel assemblies. However it is not easy to get a reasonable estimation of pressure drop due to the geometric complexity of the fuel assembly and the thin gaps between fuel assemblies. The flow rate through the gap is important part to determine the total flow rate of PCS, so it should be estimated as reasonable as possible. It requires complex and difficult jobs to get useful data. In this study CFD analysis to predict the flow distribution and the pressure drop were conducted on the plate type fuel assembly, which results would be used to be preliminary data to determine the PCS flow rate and to improve the design of a fuel assembly

  18. Modeling and simulation of PEM fuel cell's flow channels using CFD techniques

    International Nuclear Information System (INIS)

    Cunha, Edgar F.; Andrade, Alexandre B.; Robalinho, Eric; Bejarano, Martha L.M.; Linardi, Marcelo; Cekinski, Efraim

    2007-01-01

    Fuel cells are one of the most important devices to obtain electrical energy from hydrogen. The Proton Exchange Membrane Fuel Cell (PEMFC) consists of two important parts: the Membrane Electrode Assembly (MEA), where the reactions occur, and the flow field plates. The plates have many functions in a fuel cell: distribute reactant gases (hydrogen and air or oxygen), conduct electrical current, remove heat and water from the electrodes and make the cell robust. The cost of the bipolar plates corresponds up to 45% of the total stack costs. The Computational Fluid Dynamic (CFD) is a very useful tool to simulate hydrogen and oxygen gases flow channels, to reduce the costs of bipolar plates production and to optimize mass transport. Two types of flow channels were studied. The first type was a commercial plate by ELECTROCELL and the other was entirely projected at Programa de Celula a Combustivel (IPEN/CNEN-SP) and the experimental data were compared with modelling results. Optimum values for each set of variables were obtained and the models verification was carried out in order to show the feasibility of this technique to improve fuel cell efficiency. (author)

  19. Coil-springs used as mechanical filter. Modification of the bottom tie plate of a fuel assembly

    International Nuclear Information System (INIS)

    Nylund, O.

    1993-01-01

    Describes an improved design of the bottom tie plate of a fuel assembly. The improvement of the design is an arrangement of horizontal channels holding coil-springs and crossing the vertical channels for the cooling water. The coil-springs work as strainers for the cooling water

  20. Folic Acid Supplementation Delays Atherosclerotic Lesion Development by Modulating MCP1 and VEGF DNA Methylation Levels In Vivo and In Vitro

    Science.gov (United States)

    Cui, Shanshan; Li, Wen; Lv, Xin; Wang, Pengyan; Gao, Yuxia; Huang, Guowei

    2017-01-01

    The pathogenesis of atherosclerosis has been partly acknowledged to result from aberrant epigenetic mechanisms. Accordingly, low folate levels are considered to be a contributing factor to promoting vascular disease because of deregulation of DNA methylation. We hypothesized that increasing the levels of folic acid may act via an epigenetic gene silencing mechanism to ameliorate atherosclerosis. Here, we investigated the atheroprotective effects of folic acid and the resultant methylation status in high-fat diet-fed ApoE knockout mice and in oxidized low-density lipoprotein-treated human umbilical vein endothelial cells. We analyzed atherosclerotic lesion histology, folate concentration, homocysteine concentration, S-adenosylmethionine (SAM) and S-adenosylhomocysteine (SAH), and DNA methyltransferase activity, as well as monocyte chemotactic protein-1 (MCP1) and vascular endothelial growth factor (VEGF) expression and promoter methylation. Folic acid reduced atherosclerotic lesion size in ApoE knockout mice. The underlying folic acid protective mechanism appears to operate through regulating the normal homocysteine state, upregulating the SAM: SAH ratio, elevating DNA methyltransferase activity and expression, altering MCP1 and VEGF promoter methylation, and inhibiting MCP1 and VEGF expression. We conclude that folic acid supplementation effectively prevented atherosclerosis by modifying DNA methylation through the methionine cycle, improving DNA methyltransferase activity and expression, and thus changing the expression of atherosclerosis-related genes. PMID:28475147

  1. An experimental study towards the practical application of closed-loop flat-plate pulsating heat pipes

    NARCIS (Netherlands)

    Groeneveld, Gerben; Van Gerner, Henk Jan; Wits, Wessel W.

    2017-01-01

    The thermal performance of a flat-plate closed-loop pulsating heat pipe (PHP) is experimentally obtained. The PHP is manufactured by means of CNC-milling and vacuum brazing of a stainless steel 316L bottom plate and lid. Each channel of the PHP has a 2×2 mm2 square cross section. In total 12

  2. TRPV1 and the MCP-1/CCR2 Axis Modulate Post-UTI Chronic Pain.

    Science.gov (United States)

    Rosen, John M; Yaggie, Ryan E; Woida, Patrick J; Miller, Richard J; Schaeffer, Anthony J; Klumpp, David J

    2018-05-08

    The etiology of chronic pelvic pain syndromes remains unknown. In a murine urinary tract infection (UTI) model, lipopolysaccharide of uropathogenic E. coli and its receptor TLR4 are required for post-UTI chronic pain development. However, downstream mechanisms of post-UTI chronic pelvic pain remain unclear. Because the TRPV1 and MCP-1/CCR2 pathways are implicated in chronic neuropathic pain, we explored their role in post-UTI chronic pain. Mice were infected with the E. coli strain SΦ874, known to produce chronic allodynia, and treated with the TRPV1 antagonist capsazepine. Mice treated with capsazepine at the time of SΦ874 infection failed to develop chronic allodynia, whereas capsazepine treatment of mice at two weeks following SΦ874 infection did not reduce chronic allodynia. TRPV1-deficient mice did not develop chronic allodynia either. Similar results were found using novelty-suppressed feeding (NSF) to assess depressive behavior associated with neuropathic pain. Imaging of reporter mice also revealed induction of MCP-1 and CCR2 expression in sacral dorsal root ganglia following SΦ874 infection. Treatment with a CCR2 receptor antagonist at two weeks post-infection reduced chronic allodynia. Taken together, these results suggest that TRPV1 has a role in the establishment of post-UTI chronic pain, and CCR2 has a role in maintenance of post-UTI chronic pain.

  3. Preservação dos atributos físicos de frutos de atemoia cv. Gefner com o uso de 1-MCP e atmosfera modificad

    Directory of Open Access Journals (Sweden)

    Gláucia Michelle Cosme Silva

    2014-12-01

    Full Text Available O interesse comercial pela atemoia vem aumentando cada vez mais no Brasil. O aumento da atividade respiratória, acompanhado por modificações rápidas na composição física dos frutos podem inviabilizar sua distribuição a mercados distantes. Neste contexto, objetivou-se com o presente trabalho avaliar os atributos físicos em frutos de atemoia tratados com 1-metilciclopropeno (1-MCP e atmosfera modificada associados à refrigeração. O experimento foi instalado em delineamento experimental inteiramente casualizado, em esquema fatorial 4x5, sendo quatro concentrações de 1-MCP (0; 200; 400 e 600 ŋL L-¹ e cinco períodos de avaliação após a colheita, em intervalo de cinco dias, com quatro repetições e quatro frutos por unidade experimental. As atemoias foram colhidas em pomar comercial, no município de Matias Cardoso-MG, no estádio de maturação fisiológica, lavadas, sanitizadas e secas ao ar, depois tratadas com as concentrações de 1-MCP por oito horas, em temperatura ambiente. Logo após, quatro frutos foram dispostos em bandejas de poliestireno expandido. Alguns permaneceram sem membrana, enquanto outros foram embalados com membrana plástica de PEBD 16µm. As variáveis avaliadas nos frutos foram: perda de biomassa fresca, firmeza, concentração de CO2, etileno e coloração da casca. O uso da atmosfera modificada e do 1-MCP, associados ou não, foi eficiente no atraso do amadurecimento dos frutos, permitindo a conservação de sua qualidade física. Frutos tratados com 1-MCP apresentaram-se mais firmes, além da preservação da coloração, verificada através da luminosidade, cromaticidade e ângulo Hueº, que se mostraram superiores quando comparados aos frutos não tratados.

  4. Benchmarking a computational fluid dynamics model of separated flow in a thin rectangular channel for use in predictive design analysis

    International Nuclear Information System (INIS)

    Stovall, T.K.; Crabtree, A.; Felde, D.

    1995-01-01

    The Advanced Neutron Source (ANS) reactor is being designed to provide a research tool with capabilities beyond those of any existing reactors. One portion of its state-of-the-art design requires high speed fluid flow through narrow channels between the fuel plates in the core. Experience with previous reactors has shown that fuel plate damage can occur when debris becomes lodged at the entrance to these channels. Such debris can disrupt the fluid flow to the plate surfaces and prevent adequate cooling of the fuel. Preliminary ANS designs addressed this issue by providing an unheated entrance length for each fuel plate. In theory, any flow disruption would recover within this unheated length, thus providing adequate heat removal from the downstream heated portions of the fuel plates

  5. Active Vibration Control of Plate Partly Treated with ACLD Using Hybrid Control

    Directory of Open Access Journals (Sweden)

    Dongdong Zhang

    2014-01-01

    Full Text Available A finite element model of plate partly treated with ACLD treatments is developed based on the constitutive equations of elastic, piezoelectric, viscoelastic materials and Hamilton’s principle. The Golla-Hughes-Mctavish (GHM method is employed to describe the frequency-dependent characteristics of viscoelastic material (VEM. A model reduction is completed by using iterative dynamic condensation and balance model reduction method to design an effective control system. The emphasis is concerned on hybrid (combined feedback/feedforward control system to attenuate the vibration of plates with ACLD treatments. The optimal linear quadratic Gaussian (LQG controller is considered as a feedback channel and the adaptive filtered-reference LMS (FxLMS controller is used as a feedforward channel. They can be utilized individually or in a hybrid way to suppress the vibration of plate/ACLD system. The results show that the hybrid controller which combines feedback/feedforward together can reduce the displacement amplitude of plate/ACLD system subjected to a complicated disturbance substantially without requiring more control effort. Furthermore, the hybrid controller has more rapid and stable convergence rate than the adaptive feedforward FxLMS controller. Meanwhile, perfect robustness to phase error of the cancellation path in feedforward controller and the weight matrices in feedback LQG controller is demonstrated in proposed hybrid controller. Therefore, its application in structural engineering can be highly appreciated.

  6. Highly conductive thermoplastic composite blends suitable for injection molding of bipolar plates

    International Nuclear Information System (INIS)

    Mighri, F.; Huneault, M.A.; Champagne, M.F.

    2003-01-01

    This study aimed at developing highly conductive, lightweight, and low-cost bipolar plates for use in proton exchange membranes (PEM) fuel cells. Injection and compression molding of highly filled polypropylene, PP, and polyphenylene sulfide, PPS, based blends were used as a mean for mass production of bipolar plates. Loadings up to 60-wt% in the form of graphite, conductive carbon black and carbon fibers were investigated. The developed formulations have a combination of properties and processability suitable for bipolar plate manufacturing, such as good chemical resistance, sufficient fluidity, and good electrical and thermal conductivity. Electrical resistivities around 0.15 and 0.09 Ohm-cm were respectively achieved for the PP and PPS-based blends, respectively. Two bipolar plate designs were successfully fabricated by molding the gas flow channels over aluminum plates to form a metallic/polymer composite plate, or simply by direct injection molding of the conductive polymer composite. For the first design, overall plate resistivities of 0.2 and 0.1 Ohm-cm were respectively attained using PP and PPS based blends as conductive skin. A lower volume resistivity of around 0.06 Ohm-cm was attained for the second injected plate design with PPS based blend. (author)

  7. A numerical study of the supercritical CO2 plate heat exchanger subject to U-type, Z-type, and multi-pass arrangements

    Science.gov (United States)

    Zhu, Chen-Xi; Wang, Chi-Chuan

    2018-01-01

    This study proposes a numerical model for plate heat exchanger that is capable of handling supercritical CO2 fluid. The plate heat exchangers under investigation include Z-type (1-pass), U-type (1-pass), and 1-2 pass configurations. The plate spacing is 2.9 mm with a plate thickness of 0.8 mm, and the size of the plate is 600 mm wide and 218 mm in height with 60 degrees chevron angle. The proposed model takes into account the influence of gigantic change of CO2 properties. The simulation is first compared with some existing data for water-to-water plate heat exchangers with good agreements. The flow distribution, pressure drop, and heat transfer performance subject to the supercritical CO2 in plate heat exchangers are then investigated. It is found that the flow velocity increases consecutively from the entrance plate toward the last plate for the Z-type arrangement, and this is applicable for either water side or CO2 side. However, the flow distribution of the U-type arrangement in the water side shows opposite trend. Conversely, the flow distribution for U-type arrangement of CO2 depends on the specific flow ratio (C*). A lower C* like 0.1 may reverse the distribution, i.e. the flow velocity increases moderately alongside the plate channel like Z-type while a large C* of 1 would resemble the typical distribution in water channel. The flow distribution of CO2 side at the first and last plate shows a pronounced drop/surge phenomenon while the channels in water side does not reveal this kind of behavior. The performance of 2-pass plate heat exchanger, in terms of heat transfer rate, is better than that of 1-pass design only when C* is comparatively small (C* < 0.5). Multi-pass design is more effective when the dominant thermal resistance falls in the CO2 side.

  8. A two-dimensional fully analytical model with polarization effect for off-state channel potential and electric field distributions of GaN-based field-plated high electron mobility transistor

    International Nuclear Information System (INIS)

    Mao Wei; She Wei-Bo; Zhang Chao; Zhang Jin-Cheng; Zhang Jin-Feng; Liu Hong-Xia; Yang Lin-An; Zhang Kai; Zhao Sheng-Lei; Chen Yong-He; Zheng Xue-Feng; Hao Yue; Yang Cui; Ma Xiao-Hua

    2014-01-01

    In this paper, we present a two-dimensional (2D) fully analytical model with consideration of polarization effect for the channel potential and electric field distributions of the gate field-plated high electron mobility transistor (FP-HEMT) on the basis of 2D Poisson's solution. The dependences of the channel potential and electric field distributions on drain bias, polarization charge density, FP structure parameters, AlGaN/GaN material parameters, etc. are investigated. A simple and convenient approach to designing high breakdown voltage FP-HEMTs is also proposed. The validity of this model is demonstrated by comparison with the numerical simulations with Silvaco—Atlas. The method in this paper can be extended to the development of other analytical models for different device structures, such as MIS-HEMTs, multiple-FP HETMs, slant-FP HEMTs, etc. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  9. Monocytes infiltrate the pancreas via the MCP-1/CCR2 pathway and differentiate into stellate cells.

    Directory of Open Access Journals (Sweden)

    Kazuko Ino

    Full Text Available Recent studies have shown that monocytes possess pluripotent plasticity. We previously reported that monocytes could differentiate into hepatic stellate cells. Although stellate cells are also present in the pancreas, their origin remains unclear. An accumulation of enhanced green fluorescent protein (EGFP(+CD45(- cells was observed in the pancreases and livers of chimeric mice, which were transplanted with a single hematopoietic stem cell isolated from EGFP-transgenic mice and treated with carbon tetrachloride (CCl4. Because the vast majority of EGFP(+CD45(- cells in the pancreas expressed stellate cell-associated antigens such as vimentin, desmin, glial fibrillary acidic protein, procollagen-I, and α-smooth muscle actin, they were characterized as pancreatic stellate cells (PaSCs. EGFP(+ PaSCs were also observed in CCl4-treated mice adoptively transferred with monocytes but not with other cell lineages isolated from EGFP-transgenic mice. The expression of monocyte chemoattractant protein-1 (MCP-1 and angiotensin II (Ang II increased in the pancreas of CCl4-treated mice and their respective receptors, C-C chemokine receptor 2 (CCR2 and Ang II type 1 receptor (AT1R, were expressed on Ly6C(high monocytes isolated from EGFP-transgenic mice. We examined the effect of an AT1R antagonist, irbesartan, which is also a CCR2 antagonist, on the migration of monocytes into the pancreas. Monocytes migrated toward MCP-1 but not Ang II in vitro. Irbesartan inhibited not only their in vitro chemotaxis but also in vivo migration of adoptively transferred monocytes from peripheral blood into the pancreas. Irbesartan treatment significantly reduced the numbers of EGFP(+F4/80(+CCR2(+ monocytic cells and EGFP(+ PaSCs in the pancreas of CCl4-treated chimeric mice receiving EGFP(+ bone marrow cells. A specific CCR2 antagonist RS504393 inhibited the occurrence of EGFP(+ PaSCs in injured mice. We propose that CCR2(+ monocytes migrate into the pancreas possibly via the

  10. Heat transfer in plate heat exchanger channels: Experimental validation of selected correlation equations

    Directory of Open Access Journals (Sweden)

    Cieśliński Janusz T.

    2016-09-01

    Full Text Available This study is focused on experimental investigation of selected type of brazed plate heat exchanger (PHEx. The Wilson plot approach was applied in order to estimate heat transfer coefficients for the PHEx passages. The main aim of the paper was to experimentally check ability of several correlations published in the literature to predict heat transfer coefficients by comparison experimentally obtained data with appropriate predictions. The results obtained revealed that Hausen and Dittus-Boelter correlations underestimated heat transfer coefficient for the tested PHEx by an order of magnitude. The Aspen Plate code overestimated heat transfer coefficient by about 50%, while Muley-Manglik correlation overestimated it from 1% to 25%, dependent on the value of Reynolds number and hot or cold liquid side.

  11. Edge plasma control: Particle channeling in Tore Supra pump limiter and ergodic divertor

    International Nuclear Information System (INIS)

    Ghendrih, P.; Samain, A.; Grosman, A.; Capes, H.; Morera, J.P.

    1989-01-01

    Improved pumping efficiency can be achieved on Tore Supra by channeling process for particles, i.e. channeling of neutrals in the throat of pump limiters and channeling of plasma towards neutralizer plates in the ergodic divertor. The plugging length for the pump limiter throat is computed and numerical evidence of plasma flux channeling between the conductor bars of the ergodic divertor is presented. The effect of the Tore Supra ergodic divertor on edge plasma state and edge plasma transport is discussed. (orig.)

  12. Stacks with TiN/titanium as the bipolar plate for PEMFCs

    International Nuclear Information System (INIS)

    Ren, Zhijun; Zhang, Dongming; Wang, Zaiyi

    2012-01-01

    Proton exchange membrane fuel cell (PEMFC) is a potential alternative for the internal combustion engine. But many problems, such as metallic bipolar plate instead of graphite bipolar plate to decrease the cost, should be solved before its application. Based on the previous results that single cell with TiN/Ti as bipolar plates shows high performance and enough long-time durability, the progress on the stacks with TiN/Ti as bipolar plates is reported in this manuscript. Till now seldom report is focused on stacks because of the complicated processing technique, especially for that with TiN/Ti as bipolar plate. The flow field in the plate is punched from titanium deformation, and two plates are welded by laser welding to form one piece of bipolar plate. The adopted processing techniques for stacks with TiN/Ti as bipolar plate exhibit advantage and feasibility in industry. The power density by weight for the stack is as high as 1353 W kg −1 , although it still has space to be improved. Next work should be focused on the design of flow channel parameters and flow field type based on plastic deformation of metal materials. -- Highlights: ► The progress on the stacks with TiN/Ti as bipolar plates is reported. ► The adopted processing techniques exhibit feasibility in industry. ► The power density by weight for the stack is as high as 1353 W kg −1 .

  13. Numerical simulation for rib and channel position effect on PEMFC performances

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Zhixiang; Wang, Cheng; Mao, Zongqiang [Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084 (China); Zhang, Haiyong [Lab of Sail, Cable and Paints, Navy Equipment Technology Institute, Beijing, 102442 (China)

    2010-04-15

    Simulation is an important method for engineers to probe the detailed transportation and reaction information inside fuel cells and guide their designs without large amount of experiments. Although many papers discussing fuel cell flow fields design could be found in documents, relative positions of the ribs and channels in the anode and cathode flow field plates haven't been paid attention to surprisingly. In this paper, simulation results were given to explain the influences of relative positions of the ribs and channels in the anode and cathode flow field plates on the proton exchange membrane fuel cell (PEMFC) performances. It is interesting that the influence differs with several factors and the information will be helpful for fuel cell design. (author)

  14. Evaluation of BICRON NE MCP DXT-RAD passive extremity dosemeter

    CERN Document Server

    Yuen, P S; Frketich, G; Rotunda, J

    1999-01-01

    Passive extremity dosemeters currently used in dosimetry communities worldwide have shortcomings. In general, an extremity dosemeter has too thick a detector element, and the dosemeter response is highly energy dependent for beta rays with energies ranging from 200 keV to 2 MeV. It often does not have dosemeter identification, causing problems in the chain of custody. It is often read manually, rendering reading/packing operations very labour intensive. As a result of collaboration between AECL and BICRON NE, a new extremity dosemeter, incorporating a highly sensitive LiF:Mg,Cu,P TLD and tentatively code named MCP DXT-RAD, was developed. It has been evaluated for radiological performance against an ISO draft standard for extremity dosemeters in twelve categories: homogeneity, detection threshold, beta ray energy response, beta angular response, photon energy response, photon angular response, reproducibility, stability under various climatic conditions, linearity, residue, self irradiation, and effect of ligh...

  15. Microchannel plate special nuclear materials sensor

    International Nuclear Information System (INIS)

    Feller, W.B.; White, P.L.; White, P.B.; Siegmund, O.H.W.; Martin, A.P.; Vallerga, J.V.

    2011-01-01

    Nova Scientific Inc., is developing for the Domestic Nuclear Detection Office (DNDO SBIR no. HSHQDC-08-C-00190), a solid-state, high-efficiency neutron detection alternative to 3 He gas tubes, using neutron-sensitive microchannel plates (MCPs) containing 10 B and/or Gd. This work directly supports DNDO development of technologies designed to detect and interdict nuclear weapons or illicit nuclear materials. Neutron-sensitized MCPs have been shown theoretically and more recently experimentally, to be capable of thermal neutron detection efficiencies equivalent to 3 He gas tubes. Although typical solid-state neutron detectors typically have an intrinsic gamma sensitivity orders of magnitude higher than that of 3 He gas detectors, we dramatically reduce gamma sensitivity by combining a novel electronic coincidence rejection scheme, employing a separate but enveloping gamma scintillator. This has already resulted in a measured gamma rejection ratio equal to a small 3 He tube, without in principle sacrificing neutron detection efficiency. Ongoing improvements to the MCP performance as well as the coincidence counting geometry will be described. Repeated testing and validation with a 252 Cf source has been underway throughout the Phase II SBIR program, with ongoing comparisons to a small commercial 3 He gas tube. Finally, further component improvements and efforts toward integration maturity are underway, with the goal of establishing functional prototypes for SNM field testing.

  16. Modeling and simulation of PEM fuel cell's flow channels using CFD techniques

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, Edgar F.; Andrade, Alexandre B.; Robalinho, Eric; Bejarano, Martha L.M.; Linardi, Marcelo [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mails: efcunha@ipen.br; abodart@ipen.br; eric@ipen.br; mmora@ipen.br; mlinardi@ipen.br; Cekinski, Efraim [Instituto de Pesquisas Tecnologicas (IPT-SP), Sao Paulo, SP (Brazil)]. E-mail: cekinski@ipt.br

    2007-07-01

    Fuel cells are one of the most important devices to obtain electrical energy from hydrogen. The Proton Exchange Membrane Fuel Cell (PEMFC) consists of two important parts: the Membrane Electrode Assembly (MEA), where the reactions occur, and the flow field plates. The plates have many functions in a fuel cell: distribute reactant gases (hydrogen and air or oxygen), conduct electrical current, remove heat and water from the electrodes and make the cell robust. The cost of the bipolar plates corresponds up to 45% of the total stack costs. The Computational Fluid Dynamic (CFD) is a very useful tool to simulate hydrogen and oxygen gases flow channels, to reduce the costs of bipolar plates production and to optimize mass transport. Two types of flow channels were studied. The first type was a commercial plate by ELECTROCELL and the other was entirely projected at Programa de Celula a Combustivel (IPEN/CNEN-SP) and the experimental data were compared with modelling results. Optimum values for each set of variables were obtained and the models verification was carried out in order to show the feasibility of this technique to improve fuel cell efficiency. (author)

  17. Chemokine MCP1/CCL2 and RANTES/CCL5 gene polymorphisms influence Henoch–Schönlein purpura susceptibility and severity

    Directory of Open Access Journals (Sweden)

    Hsin-Hui Yu

    2015-04-01

    Conclusion: Our results support the fact that chemokines play important roles in the pathogenesis of HSP. MCP1/CCL2 gene polymorphisms were associated with susceptibility for HSP. RANTES/CCL5 gene polymorphisms may be related to disease severity and HSP nephritis.

  18. Effects of Roux-en-Y Gastric Bypass on Fasting and Postprandial Levels of the Inflammatory Markers YKL-40 and MCP-1 in Patients with Type 2 Diabetes and Glucose Tolerant Subjects

    Directory of Open Access Journals (Sweden)

    Stine Brinkløv Thomsen

    2013-01-01

    Full Text Available Background. The inflammatory markers YKL-40 and monocyte chemoattractant protein-1 (MCP-1 are elevated in morbidly obese patients and decline after weight loss. The objective of our study was to investigate the possible changes of YKL-40 and MCP-1, in both the fasting and the postprandial states, following Roux-en-Y gastric bypass (RYGB in subjects with type 2 diabetes (T2D and normal glucose tolerance (NGT. Methods. Ten obese patients with T2D and 10 subjects with NGT were examined in the fasting state and after a standard meal prior to and after (1 week, 3 months, and 1 year RYGB. Results. Fasting state MCP-1 levels decreased after RYGB in both groups (P values < 0.0001 whereas fasting YKL-40 levels were unchanged (P values ≥ 0.120. Postprandial MCP-1 levels showed a tendency towards a decrease on most study days; however, the changes were only significant at 1 week (P=0.001 and 1 yr (P<0.0001 in the T2D group and at 3 mo after RYGB in the NGT group (P=0.009. YKL-40 levels showed a slight, postprandial suppression on all study days in the T2D group (all P values ≤ 0.021. Conclusions. Fasting MCP-1 levels, but not YKL-40 levels, decrease after RYGB in subjects with T2D and NGT. Postprandial changes of inflammatory markers are discrete and inconsistent.

  19. Effect of Liquid/Vapour Maldistribution on the Performance of Plate Heat Exchanger Evaporators

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Kærn, Martin Ryhl; Ommen, Torben Schmidt

    2015-01-01

    Plate heat exchangers are often applied as evaporators in industrial refrigeration and heat pump systems. In the design and modelling of such heat exchangers the flow and liquid/vapour distribution is often assumed to be ideal. However, maldistribution may occur and will cause each channel...... to behave differently due to the variation of the mass flux and vapour quality. To evaluate the effect of maldistribution on the performance of plate heat exchangers, a numerical model is developed in which the mass, momentum and energy balances are applied individually to each channel, including suitable...... correlations for heat transfer and pressure drop. The flow distribution on both the refrigerant and secondary side is determined based on equal pressure drop while the liquid/vapour distribution is imposed to the model. Results show that maldistribution may cause up to a 25 % reduction of the overall heat...

  20. Numerical Study of Thermal and Flow Characteristics of Plate-Fin Heat Sink with Longitudinal Vortex Generator Installed on the Ground

    Directory of Open Access Journals (Sweden)

    Yen-Tso Chang

    2014-01-01

    Full Text Available This study applied the commercial software ANSYS CFD (FLUENT, for simulating the transient flow field and investigating the influence of each parameter of longitudinal vortex generators (LVGs on the thermal flux of a plate-fin heat sink. Vortex generator was set in front of plate-fin heat sink and under the channel, which was in common-flow-down (CFD and common-flow-up (CFU conditions, which have the result of vortex generator of delta winglet pair (DWP. In this study the parameters were varied, such as the minimum transverse distance between winglet pair, the attack angle of the vortex generator, fins number, the fin height, and the distance between the vortex generator and plate-fin. The coolant fluid flew into the fin-to-fin channel and pushed the vortex from different geometry toward the bottom. This phenomenon took off the heat from the plate to enhance the heat transfer. The numerical results indicated that the LVGs located close to the plate-fin heat sink are zero with the attack angle being 30°, presenting optimal overall conditions.

  1. A very large multigap resistive plate chamber

    CERN Document Server

    Cerron-Zeballos, E; Hatzifotiadou, D; Kim, D W; Lamas-Valverde, J; Lee, S C; Platner, E D; Roberts, J; Williams, M C S; Zichichi, A

    1999-01-01

    We have built and tested a very large multigap resistive plate chamber (MRPC). We discuss the suitability of the multigap RPC for the construction of large area modules. We give details of the construction technique and results from a scan across the surface of the chamber. We also report on the implementation of `half-strip resolution', where we improve the spatial resolution by a factor 2 without increasing the number of read-out channels. (9 refs).

  2. Transient thermal hydraulic modeling and analysis of ITER divertor plate system

    International Nuclear Information System (INIS)

    El-Morshedy, Salah El-Din; Hassanein, Ahmed

    2009-01-01

    A mathematical model has been developed/updated to simulate the steady state and transient thermal-hydraulics of the International Thermonuclear Experimental Reactor (ITER) divertor module. The model predicts the thermal response of the armour coating, divertor plate structural materials and coolant channels. The selected heat transfer correlations cover all operating conditions of ITER under both normal and off-normal situations. The model also accounts for the melting, vaporization, and solidification of the armour material. The developed model is to provide a quick benchmark of the HEIGHTS multidimensional comprehensive simulation package. The present model divides the coolant channels into a specified axial regions and the divertor plate into a specified radial zones, then a two-dimensional heat conduction calculation is created to predict the temperature distribution for both steady and transient states. The model is benchmarked against experimental data performed at Sandia National Laboratory for both bare and swirl tape coolant channel mockups. The results show very good agreements with the data for steady and transient states. The model is then used to predict the thermal behavior of the ITER plasma facing and structural materials due to plasma instability event where 60 MJ/m 2 plasma energy is deposited over 500 ms. The results for ITER divertor response is analyzed and compared with HEIGHTS results.

  3. Transient thermal hydraulic modeling and analysis of ITER divertor plate system

    Energy Technology Data Exchange (ETDEWEB)

    El-Morshedy, Salah El-Din [Argonne National Laboratory, Argonne, IL (United States); Atomic Energy Authority, Cairo (Egypt)], E-mail: selmorshedy@etrr2-aea.org.eg; Hassanein, Ahmed [Purdue University, West Lafayette, IN (United States)], E-mail: hassanein@purdue.edu

    2009-12-15

    A mathematical model has been developed/updated to simulate the steady state and transient thermal-hydraulics of the International Thermonuclear Experimental Reactor (ITER) divertor module. The model predicts the thermal response of the armour coating, divertor plate structural materials and coolant channels. The selected heat transfer correlations cover all operating conditions of ITER under both normal and off-normal situations. The model also accounts for the melting, vaporization, and solidification of the armour material. The developed model is to provide a quick benchmark of the HEIGHTS multidimensional comprehensive simulation package. The present model divides the coolant channels into a specified axial regions and the divertor plate into a specified radial zones, then a two-dimensional heat conduction calculation is created to predict the temperature distribution for both steady and transient states. The model is benchmarked against experimental data performed at Sandia National Laboratory for both bare and swirl tape coolant channel mockups. The results show very good agreements with the data for steady and transient states. The model is then used to predict the thermal behavior of the ITER plasma facing and structural materials due to plasma instability event where 60 MJ/m{sup 2} plasma energy is deposited over 500 ms. The results for ITER divertor response is analyzed and compared with HEIGHTS results.

  4. Modeling particulate removal in plate-plate and wire-plate electrostatic precipitators

    Directory of Open Access Journals (Sweden)

    S Ramechecandane

    2016-09-01

    Full Text Available The present study is concerned with the modeling of electrically charged particles in a model plate-plate and a single wire-plate electrostatic precipitator (ESP. The particle concentration distributions for both a plate-plate and a wire-plate ESP are calculated using a modified drift flux model. Numerical investigations are performed using the modified drift flux model for particle number concentration, in addition to the RNG k - ε model for the mean turbulent flow field and the Poisson equation for the electric field. The proposed model and the outlined methodology for coupling the flow field, electric field, charging kinetics and particle concentration is applied to two model precipitators that are truly representative of a wide class of commercialized ESPs. The present investigation is quite different from the earlier studies as it does not make assumptions like a homogeneous electric field or an infinite turbulent diffusivity. The electric field calculated is a strong function of position and controls the migration velocity of particles. Hence, the proposed model can be implemented in a flow solver to obtain a full-fledged solution for any kind of ESP with no limitations on the particle number concentration, as encountered in a Lagrangian approach. The effect of turbulent diffusivity on particle number concentration in a plate-plate ESP is investigated in detail and the results obtained are compared with available experimental data. Similarly, the effect of particle size/diameter and applied electric potential on the accumulative collection performance in the case of a wire-plate ESP is studied and the results obtained are compared with available numerical data. The numerical results obtained using the modified drift flux model for both the plate-plate and wire-plate ESP are in close agreement with available experimental and numerical data.

  5. Advanced porous electrodes with flow channels for vanadium redox flow battery

    Science.gov (United States)

    Bhattarai, Arjun; Wai, Nyunt; Schweiss, Ruediger; Whitehead, Adam; Lim, Tuti M.; Hng, Huey Hoon

    2017-02-01

    Improving the overall energy efficiency by reducing pumping power and improving flow distribution of electrolyte, is a major challenge for developers of flow batteries. The use of suitable channels can improve flow distribution through the electrodes and reduce flow resistance, hence reducing the energy consumption of the pumps. Although several studies of vanadium redox flow battery have proposed the use of bipolar plates with flow channels, similar to fuel cell designs, this paper presents the use of flow channels in the porous electrode as an alternative approach. Four types of electrodes with channels: rectangular open channel, interdigitated open cut channel, interdigitated circular poked channel and cross poked circular channels, are studied and compared with a conventional electrode without channels. Our study shows that interdigitated open channels can improve the overall energy efficiency up to 2.7% due to improvement in flow distribution and pump power reduction while interdigitated poked channel can improve up to 2.5% due to improvement in flow distribution.

  6. Phenolic excipients of insulin formulations induce cell death, pro-inflammatory signaling and MCP-1 release

    Directory of Open Access Journals (Sweden)

    Claudia Weber

    2015-01-01

    Insulin solutions displayed cytotoxic and pro-inflammatory potential caused by phenol or m-cresol. We speculate that during insulin pump therapy phenol and m-cresol might induce cell death and inflammatory reactions at the infusion site in vivo. Inflammation is perpetuated by release of MCP-1 by activated monocytic cells leading to enhanced recruitment of inflammatory cells. To minimize acute skin complications caused by phenol/m-cresol accumulation, a frequent change of infusion sets and rotation of the infusion site is recommended.

  7. A Numerical Study on Laminar Free Convection between Vertical Flat Plates with Symmetric Heating

    Directory of Open Access Journals (Sweden)

    Ameer A. Jadoaa

    2012-06-01

    Full Text Available The development of free convection in a viscous fluid between heated plates is investigated. The basic governing continuity, momentum, and energy equations are solved numerically by finite difference method. Results are obtained for the variations of Nusselt number, velocity, temperature, and pressure throughout the flow field assuming the fluid to enter the channel with ambient temperature and a flat velocity profile. The flow and heat-transfer characteristics of the channel are studied and a development height established. Heating plate condition is (C.W.T and C.H.F. An correlation equation has been deduced for the average Nusselt number as a function of Rayligt number. A comparison is made between the results of this theoretical investigation and theoretical work of (Bodoia, J.R 1962[1].

  8. 75 FR 21241 - Certain Cut-to-Length Carbon Steel Plate from the People's Republic of China: Initiation of...

    Science.gov (United States)

    2010-04-23

    ... alterations are properly considered ``minor,'' the legislative history of this provision indicates there are..., the use of the merchandise, the channels of marketing and the cost of any modification relative to the... present in ASTM A830 plate without boron. See id. Channels of Marketing Domestic Producers state the...

  9. Imaging megathrust zone and Yakutat/Pacific plate interface in Alaska subduction zone

    Science.gov (United States)

    Kim, Y.; Abers, G. A.; Li, J.; Christensen, D. H.; Calkins, J. A.

    2013-05-01

    We image the subducted slab underneath a 450 km long transect of the Alaska subduction zone. Dense stations in southern Alaska are set up to investigate (1) the geometry and velocity structure of the downgoing plate and their relation to slab seismicity, and (2) the interplate coupled zone where the great 1964 (magnitude 9.3) had greatest rupture. The joint teleseismic migration of two array datasets (MOOS, Multidisciplinary Observations of Onshore Subduction, and BEAAR, Broadband Experiment Across the Alaska Range) based on teleseismic receiver functions (RFs) using the MOOS data reveal a shallow-dipping prominent low-velocity layer at ~25-30 km depth in southern Alaska. Modeling of these RF amplitudes shows a thin (<6.5 km) low-velocity layer (shear wave velocity of ~3 km/s), which is ~20-30% slower than normal oceanic crustal velocities, between the subducted slab and the overriding North American plate. The observed low-velocity megathrust layer (with P-to-S velocity ratio (Vp/Vs) exceeding 2.0) may be due to a thick sediment input from the trench in combination of elevated pore fluid pressure in the channel. The subducted crust below the low-velocity channel has gabbroic velocities with a thickness of 11-12 km. Both velocities and thickness of the low-velocity channel abruptly increase as the slab bends in central Alaska, which agrees with previously published RF results. Our image also includes an unusually thick low-velocity crust subducting with a ~20 degree dip down to 130 km depth at approximately 200 km inland beneath central Alaska. The unusual nature of this subducted segment has been suggested to be due to the subduction of the Yakutat terrane. We also show a clear image of the Yakutat and Pacific plate subduction beneath the Kenai Peninsula, and the along-strike boundary between them at megathrust depths. Our imaged western edge of the Yakutat terrane, at 25-30 km depth in the central Kenai along the megathrust, aligns with the western end of the

  10. Use of a Fluorometric Imaging Plate Reader in high-throughput screening

    Science.gov (United States)

    Groebe, Duncan R.; Gopalakrishnan, Sujatha; Hahn, Holly; Warrior, Usha; Traphagen, Linda; Burns, David J.

    1999-04-01

    High-throughput screening (HTS) efforts at Abbott Laboratories have been greatly facilitated by the use of a Fluorometric Imaging Plate Reader. The FLIPR consists of an incubated cabinet with integrated 96-channel pipettor and fluorometer. An argon laser is used to excite fluorophores in a 96-well microtiter plate and the emitted fluorometer. An argon laser is used to excite fluorophores in a 96-well microtiter plate and the emitted fluorescence is imaged by a cooled CCD camera. The image data is downloaded from the camera and processed to average the signal form each well of the microtiter pate for each time point. The data is presented in real time on the computer screen, facilitating interpretation and trouble-shooting. In addition to fluorescence, the camera can also detect luminescence form firefly luciferase.

  11. Effects of Roux-en-Y Gastric Bypass on Fasting and Postprandial Levels of the Inflammatory Markers YKL-40 and MCP-1 in Patients with Type 2 Diabetes and Glucose Tolerant Subjects

    DEFF Research Database (Denmark)

    Thomsen, Stine Brinkløv; Rathcke, Camilla Noelle; Jørgensen, Nils Bruun

    2013-01-01

    Background. The inflammatory markers YKL-40 and monocyte chemoattractant protein-1 (MCP-1) are elevated in morbidly obese patients and decline after weight loss. The objective of our study was to investigate the possible changes of YKL-40 and MCP-1, in both the fasting and the postprandial states......, following Roux-en-Y gastric bypass (RYGB) in subjects with type 2 diabetes (T2D) and normal glucose tolerance (NGT). Methods. Ten obese patients with T2D and 10 subjects with NGT were examined in the fasting state and after a standard meal prior to and after (1 week, 3 months, and 1 year) RYGB. Results....... Fasting state MCP-1 levels decreased after RYGB in both groups (P values...

  12. Hollow core plasma channel generation

    International Nuclear Information System (INIS)

    Quast, Heinrich Martin

    2018-03-01

    The use of a hollow plasma channel in plasma-based acceleration has beneficial properties for the acceleration of electron and positron bunches. In the scope of the FLASHForward facility at DESY, the generation of such a plasma structure is examined. Therefore, the generation of a ring-shaped laser intensity profile with different techniques is analyzed. From the obtained intensity profiles the electron density of a hollow plasma channel is simulated in the focal region. Different parameters are scanned to understand their influence on the electron density distribution - an important parameter being, for example, the radius of the central region of the channel. In addition to the simulations, experiments are presented, during which a laser pulse is transformed into a hollow beam with a spiral phase plate. Subsequently, it forms a plasma during the interaction with hydrogen, where the plasma is imaged with interferometry. For energies above 0.9 mJ a hollow plasma structure can be observed at the location of first plasma formation.

  13. Divergent plate motion drives rapid exhumation of (ultra)high pressure rocks

    Science.gov (United States)

    Liao, Jie; Malusà, Marco G.; Zhao, Liang; Baldwin, Suzanne L.; Fitzgerald, Paul G.; Gerya, Taras

    2018-06-01

    Exhumation of (ultra)high pressure [(U)HP] rocks by upper-plate divergent motion above an unbroken slab, first proposed in the Western Alps, has never been tested by numerical methods. We present 2D thermo-mechanical models incorporating subduction of a thinned continental margin beneath either a continental or oceanic upper plate, followed by upper-plate divergent motion away from the lower plate. Results demonstrate how divergent plate motion may trigger rapid exhumation of large volumes of (U)HP rocks directly to the Earth's surface, without the need for significant overburden removal by erosion. Model exhumation paths are fully consistent with natural examples for a wide range of upper-plate divergence rates. Exhumation rates are systematically higher than the divergent rate imposed to the upper plate, and the modeled size of exhumed (U)HP domes is invariant for different rates of upper-plate divergence. Major variations are instead predicted at depth for differing model scenarios, as larger amounts of divergent motion may allow mantle-wedge exhumation to shallow depth under the exhuming domes. The transient temperature increase, due to ascent of mantle-wedge material in the subduction channel, has a limited effect on exhumed continental (U)HP rocks already at the surface. We test two examples, the Cenozoic (U)HP terranes of the Western Alps (continental upper plate) and eastern Papua New Guinea (oceanic upper plate). The good fit between model predictions and the geologic record in these terranes encourages the application of these models globally to pre-Cenozoic (U)HP terranes where the geologic record of exhumation is only partly preserved.

  14. Early-time measurements of soft x-ray emission in an omega-upgrade laser-produced plasma. Semi-annual report, October 1, 1996--March 31, 1997

    International Nuclear Information System (INIS)

    Griem, H.R.; Elton, R.C.; Welch, B.L.

    1997-01-01

    Beginning in January 1997 (following arrival of the FY-97 funding) we have been preparing for our first series of experiments under this grant at the University of Rochester Laboratory for Laser Energetics (LLE) on the Omega Upgrade laser facility, now scheduled to commence June 2, 1997. For these experiments we have purchased (just arrived) a four-channel gated-stripline microchannel plate (MCP) detector to be coupled to our soft x-ray flat-field grazing incidence spectrograph used previously at LLE. This will permit time-resolved 'snapshots' of the complete spectra with a resolution to times as short as 180 ps per strip. An advantage of this technique over the streak camera used previously is the lack of any carbon absorbers such as in the thin plastic cathode required for the streak camera. This eliminates absorption in the 30-44 angstrom spectral region in which we are interested for intermediate-Z target materials such as Mg, Al and Si. An auxiliary turbomolecular-drag pump has also been installed in order to obtain the necessary vacuum for optimum MCP operation

  15. Chemistry of the oxophosphinidene ligand. 2. Reactivity of the anionic complexes [MCp{P(O)R*}(CO)(2)](-) (M = Mo, W; R* = 2,4,6-C(6)H(2)(t)Bu(3)) toward electrophiles based on elements different from carbon.

    Science.gov (United States)

    Alonso, María; Alvarez, M Angeles; García, M Esther; Ruiz, Miguel A; Hamidov, Hayrullo; Jeffery, John C

    2010-12-20

    The anionic oxophosphinidene complexes (H-DBU)[MCp{P(O)R*}(CO)(2)] (M = Mo, W; R* = 2,4,6-C(6)H(2)(t)Bu(3); Cp = η(5)-C(5)H(5), DBU = 1,8-diazabicyclo [5.4.0] undec-7-ene) displayed multisite reactivity when faced with different electrophilic reagents. The reactions with the group 14 organochloride compounds ER(4-x)Cl(x) (E = Si, Ge, Sn, Pb) led to either phosphide-like, oxophosphinidene-bridged derivatives [MCp{P(OE')R*}(CO)(2)] (E' = SiMe(3), SiPh(3), GePh(3), GeMe(2)Cl) or to terminal oxophosphinidene complexes [MCp{P(O)R*}(CO)(2)(E')] (E' = SnPh(3), SnPh(2)Cl, PbPh(3); Mo-Pb = 2.8845(4) Å for the MoPb compound). A particular situation was found in the reaction with SnMe(3)Cl, this giving a product existing in both tautomeric forms, with the phosphide-like complex [MCp{P(OSnMe(3))R*}(CO)(2)] prevailing at room temperature and the tautomer [MCp{P(O)R*}(CO)(2)(SnMe(3))] being the unique species present below 203 K in dichloromethane solution. The title anions also showed a multisite behavior when reacting with transition-metal based electrophiles. Thus, the reactions with the complexes [M'Cp(2)Cl(2)] (M' = Ti, Zr) gave phosphide-like derivatives [MCp{P(OM')R*}(CO)(2)] (M = Mo, M' = TiCp(2)Cl, ZrCp(2)Cl; M = W, M' = ZrCp(2)Cl), displaying a bridging κ(1),κ(1)-P,O- oxophosphinidene ligand connecting MCp(CO)(2) and M'Cp(2)Cl metal fragments (W-P = 2.233(1) Å, O-Zr = 2.016(4) Å for the WZr compound]. In contrast, the reactions with the complex [AuCl{P(p-tol)(3)}] gave the metal-metal bonded derivatives trans-[MCp{P(O)R*}(CO)(2){AuP(p-tol)(3)}] (M = Mo, W; Mo-Au = 2.7071(7) Å). From all the above results it was concluded that the terminal oxophosphinidene complexes are preferentially formed under conditions of orbital control, while charge-controlled reactions tend to give derivatives with the electrophilic fragment bound to the oxygen atom of the oxophosphinidene ligand (phosphide-like, oxophosphinidene-bridged derivatives).

  16. Analysis of the temporal expression of chemokines and chemokine receptors during experimental granulomatous inflammation: role and expression of MIP-1α and MCP-1

    Science.gov (United States)

    Carollo, Maria; Hogaboam, Cory M; Kunkel, Stephen L; Delaney, Stephen; Christie, Mark I; Perretti, Mauro

    2001-01-01

    Chemokine expression and function was monitored in an experimental model of granulomatous tissue formation after injection of croton oil in complete Freund's adjuvant (CO/CFA) into mouse dorsal air-pouches up to 28 days. In the first week, mast cell degranulation and leukocyte influx (mononuclear cell, MNC, and polymorphonuclear cell, PMN) were associated with CXCR2, KC and macrophage inflammatory protein (MIP)-2 mRNA expression, as determined by TaqMan® reverse transcriptase-polymerase chain reaction. KC (∼400 pg mg protein−1, n=12) and MIP-2 (∼800 pg mg protein−1, n=12) proteins peaked at day 7, together with myeloperoxidase (MPO) activity. Highest MIP-1α (>1 ng mg protein−1, n=12) levels were measured at day 3. After day 7, a gradual increase in CCR2 and CCR5 mRNA, monocyte chemoattractant protein (MCP)-1 mRNA and protein expression was measured. MCP-1 protein peaked at day 21 (∼150 pg mg protein−1, n=12) and was predominantly expressed by mast cells. A gradual increase in N-acetyl-β-D-glucosaminidase (NAG) activity (maximal at 28 days) was also measured. An antiserum against MIP-1α did not modify the inflammatory response measured at day 7 (except for a 50% reduction in MIP-1α levels), but provoked a significant increase in MPO, NAG and MCP-1 levels as measured at day 21 (n=6, Pvalues (n=8, P<0.05). In conclusion, we have shown that CO/CFA initiates a complex inflammatory reaction in which initial expression of MIP-1α serves a protective role whereas delayed expression of MCP-1 seems to have a genuine pro-inflammatory role. PMID:11704636

  17. High Frequency Design Considerations for the Large Detector Number and Small Form Factor Dual Electron Spectrometer of the Fast Plasma Investigation on NASA's Magnetospheric Multiscale Mission

    Science.gov (United States)

    Kujawski, Joseph T.; Gliese, Ulrik B.; Cao, N. T.; Zeuch, M. A.; White, D.; Chornay, D. J; Lobell, J. V.; Avanov, L. A.; Barrie, A. C.; Mariano, A. J.; hide

    2015-01-01

    Each half of the Dual Electron Spectrometer (DES) of the Fast Plasma Investigation (FPI) on NASA's Magnetospheric MultiScale (MMS) mission utilizes a microchannel plate Chevron stack feeding 16 separate detection channels each with a dedicated anode and amplifier/discriminator chip. The desire to detect events on a single channel with a temporal spacing of 100 ns and a fixed dead-time drove our decision to use an amplifier/discriminator with a very fast (GHz class) front end. Since the inherent frequency response of each pulse in the output of the DES microchannel plate system also has frequency components above a GHz, this produced a number of design constraints not normally expected in electronic systems operating at peak speeds of 10 MHz. Additional constraints are imposed by the geometry of the instrument requiring all 16 channels along with each anode and amplifier/discriminator to be packaged in a relatively small space. We developed an electrical model for board level interactions between the detector channels to allow us to design a board topology which gave us the best detection sensitivity and lowest channel to channel crosstalk. The amplifier/discriminator output was designed to prevent the outputs from one channel from producing triggers on the inputs of other channels. A number of Radio Frequency design techniques were then applied to prevent signals from other subsystems (e.g. the high voltage power supply, command and data handling board, and Ultraviolet stimulation for the MCP) from generating false events. These techniques enabled us to operate the board at its highest sensitivity when operated in isolation and at very high sensitivity when placed into the overall system.

  18. Physical, chemical and sensory changes of refrigerated yellow pitahaya treated preharvest with 1-MCP

    OpenAIRE

    Liliana Serna Cock; Laura Sofía Torres Valenzuela; Alfredo Ayala Aponte

    2013-01-01

    El efecto de la aplicación de soluciones acuosas de 0, 200 y 400 mg L de 1-metilciclopropeno (1-MCP) en pitahaya amarilla en precosecha (Selenicereus megalanthus Haw) fue evaluado. Se midieron los cambios en pérdida de peso, cambio total de la coloración, azucares totales, acidez titulable, ácido ascórbico y análisis sensorial. La pitahaya fue almacenada bajo refrigeración (10°C y 85% de humedad relativa por 29 días). Dos tipos de empaque (Cajas para exportación y canastillas plá...

  19. The construction of airfoil pressure models by the plate method: Achievements, current research, technology development and potential applications

    Science.gov (United States)

    Lawing, P. L.

    1985-01-01

    A method of constructing airfoils by inscribing pressure channels on the face of opposing plates, bonding them together to form one plate with integral channels, and contour machining this plate to form an airfoil model is described. The research and development program to develop the bonding technology is described as well as the construction and testing of an airfoil model. Sample aerodynamic data sets are presented and discussed. Also, work currently under way to produce thin airfoils with camber is presented. Samples of the aft section of a 6 percent airfoil with complete pressure instrumentation including the trailing edge are pictured and described. This technique is particularly useful in fabricating models for transonic cryogenic testing, but it should find application in a wide ange of model construction projects, as well as the fabrication of fuel injectors, space hardware, and other applications requiring advanced bonding technology and intricate fluid passages.

  20. Effects of Processing Temperatures of Nickel Plating on Capacitance Density of Alumina Film Capacitor.

    Science.gov (United States)

    Jeong, Myung-Sun; Ju, Byeong-Kwon; Lee, Jeon-Kook

    2015-06-01

    We observed the effects of nickel plating temperatures for controlling the surface morphologies of the deposited nickel layers on the alumina nano-pores. The alumina nano-channels were filled with nickel at various processing temperatures of 60-90 degrees C. The electrical properties of the alumina film capacitors were changed with processing temperatures. The electroless nickel plating (ENP) at 60 degrees C improved the nickel penetration into the alumina nano-channels due to the reduced reaction rate. Nickel layers are uniformly formed on the high aspect ratio alumina pores. Due to the uniform nickel electrode, the capacitance density of the alumina film capacitors is improved by the low leakage current, dissipation factor and equivalent series resistance. Alumina film capacitors made by ENP at 60 degrees C had a high capacitance density of 160 nF/cm2.

  1. Laser beam micro-milling of micro-channels in aerospace alloys

    CERN Document Server

    Ahmed, Naveed; Al-Ahmari, Abdulrahman

    2017-01-01

    This volume is greatly helpful to micro-machining and laser engineers as it offers obliging guidelines about the micro-channel fabrications through Nd:YAG laser beam micro-milling. The book also demonstrates how the laser beam micro-milling behaves when operating under wet conditions (under water), and explores what are the pros and cons of this hybrid technique. From the predictive mathematical models, the readers can easily estimate the resulting micro-channel size against the desired laser parametric combinations. The book considers micro-channels in three highly important research materials commonly used in aerospace industry: titanium alloy Ti-6Al-4V, nickel alloy Inconel 718 and aluminum alloy AA 2024. Therefore, the book is highly practicable in the fields of micro-channel heat exchangers, micro-channel aerospace turbine blades, micro-channel heat pipes, micro-coolers and micro-channel pulsating heat plates. These are frequently used in various industries such as aerospace, automotive, biomedical and m...

  2. MCP-1, ICAM-1 and VCAM-1 are present in early aneurysmal dilatation in experimental rats

    International Nuclear Information System (INIS)

    Jun Fan; Hao-Tong; Jing Di; Fang Liu; Hai-Hua Zhao; Shu-Ling Bai; Xiang Li; Linlin Zhong

    2010-01-01

    Recent studies have suggested that inflammation actively participates in ascending aortic aneurysm formation. The aim of the present study was to evaluate the expression changes of adhesion molecules and MMPs in an experimental model of ascending aortic aneurysm induced by ascending aorta banding in Wistar rats. Twelve rats developed aortic dilation after ascending aorta banding treatment, while nine normal animals underwent surgery without banding were used as controls. Light microscope and scanning electron microscope showed that the wall of the ascending aorta became disorganized as well as infiltration by inflammatory cells in aneurysmal rats. By using immunohistochemical techniques, a significant increase in the immunostaining of MCP-1 was observed in the aneurysmal wall as compared to the normal aortic wall. Under similar experimental conditions, we also found that the immunostaining of ICAM-1 and VCAM-1 was markedly increased in the aneurysmal wall. In addition, gelatin zymo graphic analysis showed that the expression and activities of MMP-2 and MMP-9 were remarkably enhanced in the ascending aorta of ascending aortic aneurysmal rats as compared to normal rats. These results demonstrate that MCP-1, ICAM-1 and VCAM-1 are involved in the pathogenesis of ascending aortic aneurysm and an increase in the immunostaining and activity of MMP-2 and MMP-9 may promote the progression of ascending aortic aneurysm. (authors)

  3. Experimental study for flow regime of downward air-water two-phase flow in a vertical narrow rectangular channel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T. H.; Yun, B. J.; Jeong, J. H. [Pusan National University, Geunjeong-gu, Busan (Korea, Republic of)

    2015-05-15

    Studies were mostly about flow in upward flow in medium size circular tube. Although there are great differences between upward and downward flow, studies on vertical upward flow are much more active than those on vertical downward flow in a channel. In addition, due to the increase of surface forces and friction pressure drop, the pattern of gas-liquid two-phase flow bounded to the gap of inside the rectangular channel is different from that in a tube. The downward flow in a rectangular channel is universally applicable to cool the plate type nuclear fuel in research reactor. The sub-channel of the plate type nuclear fuel is designed with a few millimeters. Downward air-water two-phase flow in vertical rectangular channel was experimentally observed. The depth, width, and length of the rectangular channel is 2.35 mm, 66.7 mm, and 780 mm, respectively. The test section consists of transparent acrylic plates confined within a stainless steel frame. The flow patterns of the downward flow in high liquid velocity appeared to be similar to those observed in previous studies with upward flow. In downward flow, the transition lines for bubbly-slug and slug-churn flow shift to left in the flow regime map constructed with abscissa of the superficial gas velocity and ordinate of the superficial liquid velocity. The flow patterns observed with downward flow at low liquid velocity are different from those with upward flow.

  4. PEG-albumin plasma expansion increases expression of MCP-1 evidencing increased circulatory wall shear stress: an experimental study.

    Directory of Open Access Journals (Sweden)

    C Makena Hightower

    Full Text Available Treatment of blood loss with plasma expanders lowers blood viscosity, increasing cardiac output. However, increased flow velocity by conventional plasma expanders does not compensate for decreased viscosity in maintaining vessel wall shear stress (WSS, decreasing endothelial nitric oxide (NO production. A new type of plasma expander using polyethylene glycol conjugate albumin (PEG-Alb causes supra-perfusion when used in extreme hemodilution and is effective in treating hemorrhagic shock, although it is minimally viscogenic. An acute 40% hemodilution/exchange-transfusion protocol was used to compare 4% PEG-Alb to Ringer's lactate, Dextran 70 kDa and 6% Hetastarch (670 kDa in unanesthetized CD-1 mice. Serum cytokine analysis showed that PEG-Alb elevates monocyte chemotactic protein-1 (MCP-1, a member of a small inducible gene family, as well as expression of MIP-1α, and MIP-2. MCP-1 is specific to increased WSS. Given the direct link between increased WSS and production of NO, the beneficial resuscitation effects due to PEG-Alb plasma expansion appear to be due to increased WSS through increased perfusion and blood flow rather than blood viscosity.

  5. Hydrodynamics of a flexible plate between pitching rigid plates

    Science.gov (United States)

    Kim, Junyoung; Kim, Daegyoum

    2017-11-01

    The dynamics of a flexible plate have been studied as a model problem in swimming and flying of animals and fluid-structure interaction of plants and flags. Motivated by fish schooling and an array of sea grasses, we investigate the dynamics of a flexible plate closely placed between two pitching rigid plates. In most studies on passive deformation of the flexible plate, the plate is immersed in a uniform flow or a wavy flow. However, in this study, the flexible plate experiences periodic deformation by the oscillatory flow generated by the prescribed pitching motion of the rigid plates. In our model, the pitching axes of the rigid plates and the clamping position of the flexible plate are aligned on the same line. The flexible plate shows various responses depending on length and pitching frequency of rigid plates, thickness of a flexible plate, and free-stream velocity. To find the effect of each variable on the response of the flexible plate, amplitude of a trailing edge and modal contribution of a flapping motion are compared, and flow structure around the flexible plate is examined.

  6. Mechanistic study of fuel freezing, channel plugging, and continued coolability during fast reactor overpower excursions

    International Nuclear Information System (INIS)

    Wong, K.W.; Catton, I.; Kastenberg, W.E.

    1977-07-01

    A mechanistic model is presented which describes events following fuel pin failure which may lead to in-channel fuel plate-out. The thermal and hydraulic effects of the plate-out fuel are also evaluated. Given the amount and particle size of the fuel injected into the coolant channel during fuel pin failure, and the initial conditions of the interaction zone, the physical states of the fuel particles and the coolant in the interaction zone can be determined. The trajectories of the fuel particles in the coolant channel are determined by assuming a slip factor between the local tangential velocities of the coolant and the fuel particles. The time and distance after which a fuel particle hits a wire wrap are then determined and the impact stresses induced in the thin solid fuel crust can be evaluated

  7. Effects of Channel Geometry and Coolant Fluid on Thermoelectric Net Power

    DEFF Research Database (Denmark)

    Rezaniakolaei, Alireza; Rosendahl, Lasse; Sørensen, Kim

    2014-01-01

    Channel geometry has a strong influence on the heat transfer coefficient and cooling energy input in a heat sink. The net power output in a thermoelectric generator (TEG) can be defined as power generation minus the required cooling energy in TEG. This study aims to evaluate the net power generat......, and the maximum net power output occurs at smaller Reynolds number when the channel hydraulic diameter reduces....... generation in TEG for different size of hydraulic diameter of plate-fin heat sink and over a wide range of Reynolds number. The particular focus of this study is to find optimal Reynolds number in each considered channel hydraulic diameter and to explore optimal channel hydraulic diameter for maximum TEG net...

  8. Test-beam and laboratory characterisation of the TORCH prototype detector

    CERN Document Server

    Ros, A; Castillo-Garcia, L; Conneely, T; Cussans, D; Foehl, K; Forty, R; Frei, C; Gao, R; Gys, T; Harnew, N; Milnes, J; Piedigrossi, D; Rademacker, J; Van Dijk, M

    2017-01-01

    The TORCH time-of-flight (TOF) detector is being developed to provide particle identification up to a momentum of 10 GeV/c over a flight distance of 10 m. It has a DIRC-like construction with View the MathML source10mm thick synthetic amorphous fused-silica plates as a Cherenkov radiator. Photons propagate by total internal reflection to the plate periphery where they are focused onto an array of customised position-sensitive micro-channel plate (MCP) detectors. The goal is to achieve a 15 ps time-of-flight resolution per incident particle by combining arrival times from multiple photons. The MCPs have pixels of effective size 0.4 mm×6.6 mm2 in the vertical and horizontal directions, respectively, by incorporating a novel charge-sharing technique to improve the spatial resolution to better than the pitch of the readout anodes. Prototype photon detectors and readout electronics have been tested and calibrated in the laboratory. Preliminary results from testbeam measurements of a prototype TORCH detector are a...

  9. Experimental investigation of onset of nucleate boiling in this rectangular channels

    International Nuclear Information System (INIS)

    Belhadj, M.; Christensen, R.N.; Aldemir, T.

    1988-01-01

    The 10 kW, HEU fueled Ohio State University Research Reactor (OSURR) will be upgraded to operate with plate type LEU U 3 Si 2 , fuel elements in the power range 250-500 kW. The core will be cooled by natural convection and an onset of nucleate boiling (ONB) margin of 1.2 will be maintained in the hot channel under steady-state operation. The validity of the correlations used for predicting ONB in plate type research reactors is not known for low heat flux-low velocity flows. An experiment has been set up at The Ohio State University to investigate ONB for laminar flow in this rectangular channels. The results show that: The Bergles-Rohsenow correlation and the correlation proposed by Ricque and Siboul predict higher and lower ONB fluxes than actual, respectively. The ONB heat flux is flow velocity dependent

  10. Entropy generation in Poiseuille flow through a channel partially filled with a porous material

    Directory of Open Access Journals (Sweden)

    Kumar Vikas

    2015-01-01

    Full Text Available In the present paper, a theoretical analysis of entropy generation due to fully developed flow and heat transfer through a parallel plate channel partially filled with a porous medium under the effect of transverse magnetic field and radiation is presented. Both horizontal plates of the channel are kept at constant and equal temperature. An exact solution of governing equation for both porous and clear fluid regions has been obtained in closed form. The entropy generation number and the Bejan number are also calculated. The effects of various parameters such as magnetic field parameter, radiation parameter, Brinkman number, permeability parameter, ratios of viscosities and thermal conductivities are examined on velocity, temperature, entropy generation rate.

  11. Swath sonar mapping of Earth's submarine plate boundaries

    Science.gov (United States)

    Carbotte, S. M.; Ferrini, V. L.; Celnick, M.; Nitsche, F. O.; Ryan, W. B. F.

    2014-12-01

    The recent loss of Malaysia Airlines flight MH370 in an area of the Indian Ocean where less than 5% of the seafloor is mapped with depth sounding data (Smith and Marks, EOS 2014) highlights the striking lack of detailed knowledge of the topography of the seabed for much of the worlds' oceans. Advances in swath sonar mapping technology over the past 30 years have led to dramatic improvements in our capability to map the seabed. However, the oceans are vast and only an estimated 10% of the seafloor has been mapped with these systems. Furthermore, the available coverage is highly heterogeneous and focused within areas of national strategic priority and community scientific interest. The major plate boundaries that encircle the globe, most of which are located in the submarine environment, have been a significant focus of marine geoscience research since the advent of swath sonar mapping. While the location of these plate boundaries are well defined from satellite-derived bathymetry, significant regions remain unmapped at the high-resolutions provided by swath sonars and that are needed to study active volcanic and tectonic plate boundary processes. Within the plate interiors, some fossil plate boundary zones, major hotspot volcanoes, and other volcanic provinces have been the focus of dedicated research programs. Away from these major tectonic structures, swath mapping coverage is limited to sparse ocean transit lines which often reveal previously unknown deep-sea channels and other little studied sedimentary structures not resolvable in existing low-resolution global compilations, highlighting the value of these data even in the tectonically quiet plate interiors. Here, we give an overview of multibeam swath sonar mapping of the major plate boundaries of the globe as extracted from public archives. Significant quantities of swath sonar data acquired from deep-sea regions are in restricted-access international archives. Open access to more of these data sets would

  12. Spatial dependence of the void coefficient in the interstitial coolant channel positions of a stainless steel-clad TRIGA Mark I core

    International Nuclear Information System (INIS)

    Spriggs, Gregory D.; Nelson, George W.; Doane, Harry J.

    1982-01-01

    A new top grid plate was manufactured and installed in the U of A TRIGA. The new grid plate was identical to the old grid plate with respect to the fuel element array, but included two minor modifications; 1) 3/8'' holes were drilled in six interstitial positions between fuel element rings to allow for insertion of a small diameter void rod for void coefficient measurements in the coolant channels, and 2) flux wire holes were drilled in all remaining interstitial positions. The purpose of this report is to update the previously reported void coefficient measurements with data taken in one of the coolant channel positions

  13. On the domestic fuel channel for BWR

    International Nuclear Information System (INIS)

    Fukada, Hiroshi

    1979-01-01

    Kobe Steel Ltd. started the domestic manufacture of fuel channel boxes for BWRs in 1967, and entered the actual production stage four years after that. Since 1976, the mass production system was adopted with the increase of the demand. The requirements about the surface contamination and the dimensional accuracy over whole length are very strict in the fuel channel boxes, moreover, special consideration must be given so as to prevent the deformation in use. The unique working methods such as electron beam welding, high temperature press forming and so on are employed in Kobe Steel Ltd. to satisfy such strict requirements, therefore the quality of the produced fuel channel boxes is superior to imported ones. At present, the fuel channel boxes domestically made by Kobe Steel Ltd. are used for almost all BWRs in Japan. The functions of fuel channel boxes are to flow boiling coolant uniformly upward, to guide control rods, and to increase the rigidity of fuel assembly. The fuel channel boxes are the square tubes of zircaloy 4 of 134.06 mm inside width, 2.03 mm thickness, and 4118 or 4239 mm length. The progress of the development and the features of the fuel channel boxes and the manufacturing processes are described. Zircaloy plates are formed into channels, and two channels are electron beam-welded after the edge preparation, to make a box. Ultrasonic examination and stress relief treatment are applied, and clips and spacers are welded. (Kako, I.)

  14. Investigation of thermal energy transport from an anisotropic central heating element to the adjacent channels: A multipoint flux approximation

    KAUST Repository

    Salama, Amgad; Sun, Shuyu; El-Amin, Mohamed

    2015-01-01

    anisotropy of the heating element and/or the encompassing plates on thermal energy transport to the fluid passing through the two channels. When the medium is anisotropic with respect to thermal conductivity; energy transport to the neighboring channels

  15. Flow Reversal of Fully-Developed Mixed MHD Convection in Vertical Channels

    International Nuclear Information System (INIS)

    Saleh, H.; Hashim, I.

    2010-01-01

    The present analysis is concerned with flow reversal phenomena of the fully-developed laminar combined free and forced MHD convection in a vertical parallel-plate channel. The effect of viscous dissipation is taken into account. Flow reversal adjacent to the cold (or hot) wall is found to exist within the channel as Gr/Re is above (or below) a threshold value. Parameter zones for the occurrence of reversed flow are presented. (fundamental areas of phenomenology(including applications))

  16. Beam profile measurements on the advanced test accelerator using optical techniques

    International Nuclear Information System (INIS)

    Chong, Y.P.; Kalibjian, R.; Cornish, J.P.; Kallman, J.S.; Donnelly, D.

    1986-01-01

    Beam current density profiles of ATA have been measured both spatially and temporally using a number of diagnostics. An extremely important technique involves measuring optical emissions from either a target foil inserted into the beam path or gas atoms and molecules excited by beam electrons. This paper describes the detection of the optical emission. A 2-D gated television camera with a single or dual micro-channel-plate (MCP) detector for high gain provides excellent spatial and temporal resolution. Measurements are routinely made with resolutions of 1 mm and 5 ns respectively. The optical line of sight allows splitting part of the signal to a streak camera or photometer for even higher time resolution

  17. Radio frequency picosecond phototube

    International Nuclear Information System (INIS)

    Margaryan, A.; Carlini, R.; Ent, R.; Grigoryan, N.; Gyunashyan, K.; Hashimoto, O.; Hovater, K.; Ispiryan, M.; Knyazyan, S.; Kross, B.; Majewski, S.; Marikyan, G.; Mkrtchyan, M.; Parlakyan, L.; Popov, V.; Tang, L.; Vardanyan, H.; Yan, C.; Zhamkochyan, S.; Zorn, C.

    2006-01-01

    We propose a photon detector for recording low-level and ultra-fast optical signals, based on radio frequency (RF) analysis of low-energy photoelectrons (PEs). By using currently developed 500 MHz RF deflector, it is possible to scan circularly and detect single PEs, amplified in multi-channel plates (MCPs). The operation of the tube is investigated by means of thermionic electron source. It is demonstrated that the signals generated in the MCP can be processed event by event; by using available nanosecond electronics and that time resolution better than 20 ps can be achieved. Timing characteristics of the Cherenkov detector with RF phototube in a 'head-on' geometry is investigated by means of Monte Carlo simulation

  18. Radio frequency picosecond phototube

    Energy Technology Data Exchange (ETDEWEB)

    Margaryan, A. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia)]. E-mail: mat@mail.yerphi.am; Carlini, R. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Ent, R. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Grigoryan, N. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Gyunashyan, K. [Yerevan State University of Architecture and Construction, Yerevan (Armenia); Hashimoto, O. [Tohoku University, Sendai 98-77 (Japan); Hovater, K. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Ispiryan, M. [University of Houston, 4800 Calhoun Rd, Houston TX 77204 (United States); Knyazyan, S. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Kross, B. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Majewski, S. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Marikyan, G. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Mkrtchyan, M. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Parlakyan, L. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Popov, V. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Tang, L. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Vardanyan, H. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Yan, C. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Zhamkochyan, S. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Zorn, C. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States)

    2006-10-15

    We propose a photon detector for recording low-level and ultra-fast optical signals, based on radio frequency (RF) analysis of low-energy photoelectrons (PEs). By using currently developed 500 MHz RF deflector, it is possible to scan circularly and detect single PEs, amplified in multi-channel plates (MCPs). The operation of the tube is investigated by means of thermionic electron source. It is demonstrated that the signals generated in the MCP can be processed event by event; by using available nanosecond electronics and that time resolution better than 20 ps can be achieved. Timing characteristics of the Cherenkov detector with RF phototube in a 'head-on' geometry is investigated by means of Monte Carlo simulation.

  19. Relative contributions of decay accelerating factor (DAF), membrane cofactor protein (MCP) and CD59 in the protection of melanocytes from homologous complement

    NARCIS (Netherlands)

    Venneker, G. T.; Vodegel, R. M.; Okada, N.; Westerhof, W.; Bos, J. D.; Asghar, S. S.

    1998-01-01

    Complement regulatory molecules, membrane cofactor protein (MCP), decay accelerating factor (DAF) and CD59, protect body cells from autologous complement. They have wide tissue distribution but nothing is known about the expression of these molecules on human melanocytes. Since melanocytes are lysed

  20. The MCP-1, CCL-5 and SDF-1 chemokines as pro-inflammatory markers in generalized anxiety disorder and personality disorders.

    Science.gov (United States)

    Ogłodek, Ewa A; Szota, Anna M; Just, Marek J; Moś, Danuta M; Araszkiewicz, Aleksander

    2015-02-01

    The co-occurrence of generalized anxiety disorder and personality disorders suggests the existence of association between the neurobiological predispositions leading to the development of these disorders and activation of cytokine system. Pro-inflammatory chemokines such as CCL-5/RANTES (regulated upon activation normal T cell expressed and secreted) and CXCL12/SDF-1 (stromal derived factor) play an important role in immune response. A total of 160 participants were enrolled in the study, 120 of whom comprised the study group (people with the dual diagnosis of personality disorder and generalized anxiety disorder). The mean age was 41.4 ± 3.5 years (range: 20-44 years). The control group consisted of 40 healthy individuals in the mean age of 40.8 ± 3.1 years (range: 20-43 years). A blood sample was collected from each participant and the plasma levels of the CCL-2/MCP-1 (monocyte chemoattractant protein-1), RANTES and SDF-1 chemokines were determined by ELISA. Increased levels of MCP-1 and SDF-1 were found both in women and in men versus the control group for all types of personality disorders. The levels of CCL-5 in men were significantly increased versus the control group and significantly higher in women than in men. Neither women nor men with avoidant or obsessive-compulsive personality disorder showed any significant differences in MCP-1 or SFD-1 levels. In subjects with borderline personality disorder, the levels of the study chemokines were higher in women than in men. Our study has shown the need for determination of proinflammatory interleukins which are considered as biomarkers of personality disorders and generalized anxiety disorders. Copyright © 2014 Institute of Pharmacology, Polish Academy of Sciences. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  1. Study of capillary tracking detectors with position-sensitive photomultiplier readout

    International Nuclear Information System (INIS)

    Cardini, A.; Cavasinni, V.; Di Girolamo, B.; Dolinsky, S.I.; Flaminio, V.; Golovkin, S.V.; Gorin, A.M.; Medvedkov, A.M.; Pyshev, A.I.; Tyukov, V.E.; Vasilchenko, V.G.; Zymin, K.V.

    1995-01-01

    Measurements have been carried out on light yield and attenuation length in glass capillaries filled with new liquid scintillators (LS) and compared with analogous measurements made on 0.5 mm diameter plastic fibres Kuraray SCSF-38 and 3HF. It is found that, at a distance of 1 m, the light output in the capillary filled with green LS based on 1-methylnaphthalene doped with a new dye 3M15 is greater by a factor of 2 to 3 than for plastic fibres. A tracking detector consisting of a capillary bundle read out by a 100 channel position-sensitive microchannel plate photomultiplier (2MCP-100) has been built and tested in the laboratory using a cosmic ray trigger. A comparison has been made between the performance of such a detector and that of a similar one, read out by a 96 channel Philips XP1724/A photomultiplier. It was found that a bundle made of 20μm diameter capillaries with a tapered end giving a magnification of 2.56, filled with the new IPN+3M15 liquid scintillator, read out by the 2MCP-100, provides a space resolution of σ=170μm, a two-track resolution of the same value and a hit density of n=1.9/mm for tracks crossing the detector at a distance of 20 cm from the photocathode. If the same detector is read out by the Philips XP1724/A, the space resolution becomes 200μm, the two-track resolution 600μm and the hit density n=1.7/mm. The worse performance in the latter case is caused by the larger crosstalk compared with that of the 2MCP-100 PSPM. The results indicate that a LS-filled capillary detector is a very promising device for fast fibre tracking. (orig.)

  2. Relationship between genetic polymorphisms in MCP-1, CCR-2, and non-small-cell lung cancer in the Han nationality of Northern China.

    Science.gov (United States)

    Yang, L; Wang, J; Li, F-G; Han, M; Chang, X-J; Wang, Z-T

    2015-04-22

    Lung cancer is a common malignant tumor worldwide and is now the leading cause of cancer-related deaths. Monocyte chemoattractant protein 1 (MCP-1) and its receptor chemokine receptor 2 (CCR-2) are important chemokines. We examined the polymorphisms of 338 unrelated patients with non-small cell lung carcinoma (NSCLC) and 200 unrelated healthy controls of Han nationality in Northern China using polymerase chain reaction-restriction fragment length polymorphism. We found a significant increase in the frequency of the MCP-1 AA genotype [0.293 vs 0.195, odds ratio (OR) = 1.71, 95% confidence interval (CI) = 1.13-2.60] and a significant decrease in the frequency of the GG genotype (0.290 vs 0.41, OR = 0.64, 95%CI = 0.47-0.87) in NSCLC patients compared to controls. The frequencies of AA-ww (0.151 vs 0.090, P = 0.041, OR = 1.80, 95%CI = 1.33-2.43) and AA-wm (0.136 vs 0.080, P = 0.049, OR = 1.81, 95%CI = 1.01-3.27) were higher in lung cancer patients than in healthy controls; the frequency of GG-wm (0.121 vs 0.190, P = 0.030, OR = 0.60, 95%CI = 0.38-0.95) was lower in lung cancer patients than in healthy controls. Based on these results, the polymorphism in MCP-1 may be correlated with the development of NSCLC in the Han nationality of Northern China. However, the polymorphism in CCR-2 is not involved in NSCLC.

  3. Development of a micro-heat exchanger with stacked plates using LTCC technology

    Directory of Open Access Journals (Sweden)

    E. Vásquez-Alvarez

    2010-09-01

    Full Text Available A green ceramic tape micro-heat exchanger was developed using Low Temperature Co-fired Ceramics technology (LTCC. The device was designed by using Computational Aided Design software and simulations were made using a Computational Fluid Dynamics package (COMSOL Multiphysics to evaluate the homogeneity of fluid distribution in the microchannels. Four geometries were proposed and simulated in two and three dimensions to show that geometric details directly affect the distribution of velocity in the micro-heat exchanger channels. The simulation results were quite useful for the design of the microfluidic device. The micro-heat exchanger was then constructed using the LTCC technology and is composed of five thermal exchange plates in cross-flow arrangement and two connecting plates, with all plates stacked to form a device with external dimensions of 26 x 26 x 6 mm³.

  4. Poster - 24: Characterization of the energy dependence of high-sensitivity MCP-N TLD and Al2O3:C OSLD in-vivo dosimetry systems for 40–100 kVp energies

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, Yannick; Kuznetsova, Svetlana; Barajas, Eduardo Villarreal [Tom Baker Cancer Centre, Calgary AB, University of Calgary, Calgary AB, Tom Baker Cancer Center/University of Calgary, Calgary AB (Canada)

    2016-08-15

    Purpose: To characterize the energy dependence of high-sensitivity MCP-N TLD and Al{sub 2}O{sub 3}:C OSLD dosimetry systems at low (40–100 kVp) energies for in-vivo dosimetry. Methods: We assessed the variation of response with energy of two detectors in the 40–100 kVp energy range: high-sensitivity MCP-N TLDs (LiF:Mg,Cu,P) and OSLDs (Al{sub 2}O{sub 3}:C). The detectors were irradiated with an XRad 320ix biological irradiator under reference conditions. The delivered dose was 10 cGy for 7 beam qualities ranging from 40–100 kVp, 1.7–4.0 mm Al, and effective energies 26.9–37.9 keV. Both sets of detectors were also irradiated under reference conditions at 6 MV using a Varian Clinac 21Ex to assess the change in response from high-energy beams. Results: The MCP-N high-sensitivity TLDs were relatively insensitive to energies in the kV range, as their response varied by ±5%, i.e. well within the reproducibility limits of these detectors. However, the OSLDs exhibited a linearly-decreasing response with energy with a response 18.7% higher at 40 kVp than at 100 kVp for the same nominal dose. Compared to the 6 MV beams used in conventional radiotherapy, OSLDs responded 3.3–3.9 times higher depending on beam quality while the MCP-N TLD response was unchanged within experimental uncertainty. Conclusions: Unlike the more commonly used TLD-100, the high-sensitivity MCP-N TLDs exhibit little to no energy response. OSLDs are shown to be highly energy-dependent, both from MV to kV and within the kV range.

  5. Pressure data for various flow channels in proton exchange membrane (PEM) fuel cell

    International Nuclear Information System (INIS)

    Cho, Son Ah; Lee, Pil Hyong; Han, Sang Seok; Hwang, Sang Soon

    2008-01-01

    Micro flow channels in flow plates of fuel cells have become much narrower and longer to improve reactant flow distribution leading to increase of pumping power. Therefore it is very important to minimize the pressure drops in the flow channel because increased pumping power reduces overall efficiency. We investigated pressure drops in a micro flow channel at the anode and cathode compared to pressure losses for cold flow in straight, bended and serpentine channels. The results show that friction factors for cold flow channels could be used for parallel and bended flow channel designs for fuel cells. Pressure drop in the serpentine flow channel is the lowest among all flow channels due to bypass flow across the gas diffusion layer under reactive flow condition, although its pressure drop is highest for a cold flow condition. So the effect of bypass flow for serpentine flow channels should be considered when designing flow channels

  6. Far-Field Power Transmissions in Orthotropic Plates: A New Approach

    Directory of Open Access Journals (Sweden)

    Nirmal K. Mandal

    2008-01-01

    Full Text Available The structural intensity (SI technique is an essential tool for locating and ranking vibration sources and sinks on structures. It can quantify vibration fields by plotting a vector map of energy transmission on the structures. In this paper, a different strategy, changing coordinate systems of plate equations, is used to develop an intensity equation from shear force components in both x and y directions. The formulation is carried out in the frequency domain considering flexural waves. Orthotropic plate theory, far-field conditions, Fourier transform, and finite difference approximation are considered. The same intensity definition is obtained using this different strategy. A dual-channel FFT analyser is essential for data acquisition to get an intensity vector in a particular direction for far-field conditions.

  7. Influence of promoting blood circulation to remove blood stasis combined with laparoscopy on serum MCP-1, RANTES, oxidative stress and hormones in infertile patients with endometriosis

    Directory of Open Access Journals (Sweden)

    Xiao-Sha Zhang

    2017-11-01

    Full Text Available Objective: To observe the influence of promoting blood circulation to remove blood stasis combined with laparoscopy on serum MCP-1, RANTES, oxidative stress and hormones in infertile patients with endometriosis. Methods: A total of 60 infertile patients with endometriosis were randomly divided into observation group (30 cases and control group (30 cases. Observation group: promoting blood circulation to remove blood stasis combined with laparoscopy; control group: patients were treated only by laparoscopy. Recording and comparing the levels of MCP-1, RANTES, oxidative stress and hormones before and after treatment. Results: (1 Before treatment, there was no statistically significant difference in the serum MCP-1, RANTES, AOPP, MDA, SOD, levels between the two groups. After treatment, compared with the same group before treatment, the serum RANTES, AOPP, MDA levels of the two groups were significantly lower, the serum SOD level of the two groups were significantly higher, and those levels of observation group were significantly better than the control group, there was significant difference between the two groups. (2 Before treatment, there was no statistically significant difference in the serum FSH, LH, E2, P, PRL levels between the two groups. After treatment, compared with the same group before treatment, the serum FSH, LH, P, PRL levels of the two groups were significantly higher, the serum E2 level of the two groups were significantly lower, and those levels of observation group were significantly better than the control group, there was significant difference between the two groups. Conclusion: Promoting blood circulation to remove blood stasis combined with laparoscopy for infertile patients with endometriosis can reduce the levels of serum MCP-1, RANTES, oxidative stress, hormones and be beneficial to protect their uterine function.

  8. Identification of flow patterns by neutron noise analysis during actual coolant boiling in thin rectangular channels

    International Nuclear Information System (INIS)

    Kozma, R.; van Dam, H.; Hoogenboom, J.E.

    1992-01-01

    The primary objective of this paper is to introduce results of coolant boiling experiments in a simulated materials test reactor-type fuel assembly with plate fuel in an actual reactor environment. The experiments have been performed in the Hoger Onderwijs Reactor (HOR) research reactor at the Interfaculty Reactor Institute, Delft, The Netherlands. In the analysis, noise signals of self-powered neutron detectors located in the neighborhood of the boiling region and thermocouple in the channel wall and in the coolant are used. Flow patterns in the boiling coolant have been identified by means of analysis of probability density functions and power spectral densities of neutron noise. It is shown that boiling has an oscillating character due to partial channel blockage caused by steam slugs generated periodically between the plates. The observed phenomenon can serve as a basis for a boiling detection method in reactors with plate-type fuels

  9. Blanket Cooling Plates Mock-ups Manufactured in different Diffusion Weld Setup

    International Nuclear Information System (INIS)

    Von Der Weth, A.; Aktaa, J.

    2007-01-01

    Full text of publication follows: The breeding blanket box is considered as one of the most important components of a future fusion power plant. It will be assembled by so called cooling plates (CP) with a system of internal cooling channels. Such a CP is produced by two symmetric half pieces with half milled-in channels. Both pieces will be joined by a diffusion weld (DW) process. Within recent years a two step DW process for different EUROFER batches has been developed. It has been first applied to small laboratory scaled samples with dimensions of 25 mm x 30 mm x 40 mm. Then the DW process had then been successfully transferred to so called compact mock ups which are small CPs with dimensions of 67 mm x 70 mm x 50 mm. As third step this process has been used to manufacture a CP (465 mm x 205 mm x 50 mm) of a breeder unit in an industrial uniaxial diffusion weld setup. This paper treats the manufacturing sequence of a cooling plate and a first wall mock up in an industrial hot isostatic pressing (HIP) setup. The firstly laboratory specimens scaled diffusion weld process has been adjusted to different cooling channel dimensions and a different DW setup. The weld quality is investigated by tensile and Charpy impact testing. This allows comparison of the weld quality of mock ups welded in different DW setups. (authors)

  10. Intermittent pneumatic leg compressions acutely upregulate VEGF and MCP-1 expression in skeletal muscle.

    Science.gov (United States)

    Roseguini, Bruno T; Mehmet Soylu, S; Whyte, Jeffrey J; Yang, H T; Newcomer, Sean; Laughlin, M Harold

    2010-06-01

    Application of intermittent pneumatic compressions (IPC) is an extensively used therapeutic strategy in vascular medicine, but the mechanisms by which this method works are unclear. We tested the hypothesis that acute application (150 min) of cyclic leg compressions in a rat model signals upregulation of angiogenic factors in skeletal muscle. To explore the impact of different pressures and frequency of compressions, we divided rats into four groups as follows: 120 mmHg (2 s inflation/2 s deflation), 200 mmHg (2 s/2 s), 120 mmHg (4 s/16 s), and control (no intervention). Blood flow and leg oxygenation (study 1) and the mRNA expression of angiogenic mediators in the rat tibialis anterior muscle (study 2) were assessed after a single session of IPC. In all three groups exposed to the intervention, a modest hyperemia (approximately 37% above baseline) between compressions and a slight, nonsignificant increase in leg oxygen consumption (approximately 30%) were observed during IPC. Compared with values in the control group, vascular endothelial growth factor (VEGF) and monocyte chemotactic protein-1 (MCP-1) mRNA increased significantly (P < 0.05) only in rats exposed to the higher frequency of compressions (2 s on/2 s off). Endothelial nitric oxide synthase, matrix metalloproteinase-2, and hypoxia-inducible factor-1alpha mRNA did not change significantly following the intervention. These findings show that IPC application augments the mRNA content of key angiogenic factors in skeletal muscle. Importantly, the magnitude of changes in mRNA expression appeared to be modulated by the frequency of compressions such that a higher frequency (15 cycles/min) evoked more robust changes in VEGF and MCP-1 compared with a lower frequency (3 cycles/min).

  11. A screening method for the optimal selection of plate heat exchanger configurations

    Directory of Open Access Journals (Sweden)

    Pinto J.M.

    2002-01-01

    Full Text Available An optimization method for determining the best configuration(s of gasketed plate heat exchangers is presented. The objective is to select the configuration(s with the minimum heat transfer area that still satisfies constraints on the number of channels, the pressure drop of both fluids, the channel flow velocities and the exchanger thermal effectiveness. The configuration of the exchanger is defined by six parameters, which are as follows: the number of channels, the numbers of passes on each side, the fluid locations, the feed positions and the type of flow in the channels. The resulting configuration optimization problem is formulated as the minimization of the exchanger heat transfer area and a screening procedure is proposed for its solution. In this procedure, subsets of constraints are successively applied to eliminate infeasible and nonoptimal solutions. Examples show that the optimization method is able to successfully determine a set of optimal configurations with a minimum number of exchanger evaluations. Approximately 5 % of the pressure drop and channel velocity calculations and 1 % of the thermal simulations are required for the solution.

  12. The Parameterization of Top-Hat Particle Sensors with Microchannel-Plate-Based Detection Systems and its Application to the Fast Plasma Investigation on NASA's Magnetospheric MultiScale Mission

    Science.gov (United States)

    Gershman, Daniel J.; Gliese, Ulrik; Dorelli, John C.; Avanov, Levon A.; Barrie, Alexander C.; Chornay, Dennis J.; MacDonald, Elizabeth A.; Holland, Matthew P.; Pollock, Craig J.

    2015-01-01

    The most common instrument for low energy plasmas consists of a top-hat electrostatic analyzer geometry coupled with a microchannel-plate (MCP)-based detection system. While the electrostatic optics for such sensors are readily simulated and parameterized during the laboratory calibration process, the detection system is often less well characterized. Furthermore, due to finite resources, for large sensor suites such as the Fast Plasma Investigation (FPI) on NASA's Magnetospheric Multiscale (MMS) mission, calibration data are increasingly sparse. Measurements must be interpolated and extrapolated to understand instrument behavior for untestable operating modes and yet sensor inter-calibration is critical to mission success. To characterize instruments from a minimal set of parameters we have developed the first comprehensive mathematical description of both sensor electrostatic optics and particle detection systems. We include effects of MCP efficiency, gain, scattering, capacitive crosstalk, and charge cloud spreading at the detector output. Our parameterization enables the interpolation and extrapolation of instrument response to all relevant particle energies, detector high voltage settings, and polar angles from a small set of calibration data. We apply this model to the 32 sensor heads in the Dual Electron Sensor (DES) and 32 sensor heads in the Dual Ion Sensor (DIS) instruments on the 4 MMS observatories and use least squares fitting of calibration data to extract all key instrument parameters. Parameters that will evolve in flight, namely MCP gain, will be determined daily through application of this model to specifically tailored in-flight calibration activities, providing a robust characterization of sensor suite performance throughout mission lifetime. Beyond FPI, our model provides a valuable framework for the simulation and evaluation of future detection system designs and can be used to maximize instrument understanding with minimal calibration

  13. Corrosion resistance characteristics of stamped and hydroformed proton exchange membrane fuel cell metallic bipolar plates

    Energy Technology Data Exchange (ETDEWEB)

    Dundar, F. [NSF I/UCRC Center for Precision Forming (CPF), Virginia Commonwealth University, Richmond, VA (United States); Department of Materials Science and Engineering, Gebze Institute of Technology (Turkey); Dur, Ender; Koc, M. [NSF I/UCRC Center for Precision Forming (CPF), Virginia Commonwealth University, Richmond, VA (United States); Mahabunphachai, S. [NSF I/UCRC Center for Precision Forming (CPF), Virginia Commonwealth University, Richmond, VA (United States); National Metal and Materials Technology Center (MTEC), Pathumthani (Thailand)

    2010-06-01

    Metallic bipolar plates have several advantages over bipolar plates made from graphite and composites due to their high conductivity, low material and production costs. Moreover, thin bipolar plates are possible with metallic alloys, and hence low fuel cell stack volume and mass are. Among existing fabrication methods for metallic bipolar plates, stamping and hydroforming are seen as prominent approaches for mass production scales. In this study, the effects of important process parameters of these manufacturing processes on the corrosion resistance of metallic bipolar plates made of SS304 were investigated. Specifically, the effects of punch speed, pressure rate, stamping force and hydroforming pressure were studied as they were considered to inevitably affect the bipolar plate micro-channel dimensions, surface topography, and hence the corrosion resistance. Corrosion resistance under real fuel cell conditions was examined using both potentiodynamic and potentiostatic experiments. The majority of the results exhibited a reduction in the corrosion resistance for both stamped and hydroformed plates when compared with non-deformed blank plates of SS304. In addition, it was observed that there exist an optimal process window for punch speed in stamping and the pressure rate in hydroforming to achieve improved corrosion resistance at a faster production rate. (author)

  14. Cold plate

    Energy Technology Data Exchange (ETDEWEB)

    Marroquin, Christopher M.; O' Connell, Kevin M.; Schultz, Mark D.; Tian, Shurong

    2018-02-13

    A cold plate, an electronic assembly including a cold plate, and a method for forming a cold plate are provided. The cold plate includes an interface plate and an opposing plate that form a plenum. The cold plate includes a plurality of active areas arranged for alignment over respective heat generating portions of an electronic assembly, and non-active areas between the active areas. A cooling fluid flows through the plenum. The plenum, at the non-active areas, has a reduced width and/or reduced height relative to the plenum at the active areas. The reduced width and/or height of the plenum, and exterior dimensions of cold plate, at the non-active areas allow the non-active areas to flex to accommodate surface variations of the electronics assembly. The reduced width and/or height non-active areas can be specifically shaped to fit between physical features of the electronics assembly.

  15. Effect of the substrate orientation on the formation of He-plates in Si

    International Nuclear Information System (INIS)

    Vallet, M.; Barbot, J. F.; Declémy, A.; Beaufort, M. F.; Reboh, S.

    2013-01-01

    The effect of the crystalline orientation on the implantation-induced strain/stress and on the formation of He-plates was studied by combining high-resolution X-ray scattering and transmission electron microscopy. The highest strains are obtained in (001)-oriented implanted substrates regardless of the fluence and of the channeling effects. The anisotropic properties of the silicon that generate an anisotropic elastic response of the substrate were taken into account to explain these different values of strain. Upon specific thermal annealing, it is shown that the formation of He-plates occurs only in the (001) habit planes regardless of the orientation of the substrates, non-tilted and tilted (001)-, (110)-, and (111)-substrates. Moreover, the distribution of He-plates in the (001) variants was found to be strongly dependent on the angle of the habit plane with the surface and on the intensity of the implantation-induced strain/stress. The implantation-induced stress thus favors the formation of He-plates in specific planes (of low angle with the surface) forming different defect configurations. The nucleation and growth of He-plates are thus discussed with regard to the implantation-induced stress

  16. AFIP-7 Tomography – 2013 Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Craft, A. E. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Williams, W. J. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Abir, M. I.K. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Wachs, D. M. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2013-10-01

    This project seeks to assess the geometric stability of the U-Mo monolithic fuel system by evaluating the radiation-induced changes in the AFIP-7 experiment device. Neutron radiography and computed tomography (CT) provide valuable information about the post-irradiation condition of the fuel specimen. Tomographic reconstructions of the AFIP-7 fuel element will be analyzed to assess the geometric condition of the element after irradiation and provide information regarding the condition of the fuel, including gross geometric defects, bowing, twist, plate buckling, cracks, and other defects. The INL, in collaboration with Oregon State University (OSU), Missouri University of Science and Technology (Missouri S&T), and Real Time Tomography, is developing advanced neutron detector systems and tomographic reconstruction techniques to evaluate the AFIP-7 fuel element. Neutron computed tomography using the current neutron radiography technique available at the Neutron Radiography reactor (NRAD) is impractical due to the long time and high cost to produce a set of images for tomographic reconstruction. Advanced neutron radiography systems such as the micro-channel plate (MCP) detector and neutron computed radiography (CR) may reduce the time and cost of acquiring images for neutron CT. The MCP detector system tested at OSU and Missouri S&T provides neutron radiographs and has lower gamma sensitivity compared to other digital acquisition image systems. However, some significant, but not prohibitive, challenges must be overcome to make its use for imaging nuclear fuel more practical. Images taken with the MCP require significant image processing to reduce distortions and correct for the dynamic detector response. Also, the small active area of the detector (~30 mm diameter) requires the collection and combination of several images of a specimen, which may become time-consuming. The MCP is tested in low gamma dose environments, but should also be tested in the gamma field at the

  17. Reverse blocking characteristics and mechanisms in Schottky-drain AlGaN/GaN HEMT with a drain field plate and floating field plates

    International Nuclear Information System (INIS)

    Mao Wei; She Wei-Bo; Zhang Jin-Feng; Zheng Xue-Feng; Wang Chong; Hao Yue; Yang Cui

    2016-01-01

    In this paper, a novel AlGaN/GaN HEMT with a Schottky drain and a compound field plate (SD-CFP HEMT) is presented for the purpose of better reverse blocking capability. The compound field plate (CFP) consists of a drain field plate (DFP) and several floating field plates (FFPs). The physical mechanisms of the CFP to improve the reverse breakdown voltage and to modulate the distributions of channel electric field and potential are investigated by two-dimensional numerical simulations with Silvaco-ATLAS. Compared with the HEMT with a Schottky drain (SD HEMT) and the HEMT with a Schottky drain and a DFP (SD-FP HEMT), the superiorities of SD-CFP HEMT lie in the continuous improvement of the reverse breakdown voltage by increasing the number of FFPs and in the same fabrication procedure as the SD-FP HEMT. Two useful optimization laws for the SD-CFP HEMTs are found and extracted from simulation results. The relationship between the number of the FFPs and the reverse breakdown voltage as well as the FP efficiency in SD-CFP HEMTs are discussed. The results in this paper demonstrate a great potential of CFP for enhancing the reverse blocking ability in AlGaN/GaN HEMT and may be of great value and significance in the design and actual manufacture of SD-CFP HEMTs. (paper)

  18. Locking of metacarpophalangeal joints in a patient with acromegaly

    Energy Technology Data Exchange (ETDEWEB)

    Tani, Y.; Tanaka, N.; Isoya, Eiji [Dept. of Orthopaedic Surgery, Soseikai General Hospital, Kyoto (Japan)

    1999-11-01

    A 39-year-old man with acromegaly exhibited locking of metacarpophalangeal (MCP) joints of both index fingers. Large osteophytes were found at the metacarpal heads by radiography and computerized tomography (CT). Magnetic resonance (MR) images revealed hypertrophy of volar plates. We suggest that these characteristic acromegalic features caused locking of MCP joints. Surgery was required on one of the joints to release the locking. (orig.)

  19. Locking of metacarpophalangeal joints in a patient with acromegaly

    International Nuclear Information System (INIS)

    Tani, Y.; Tanaka, N.; Isoya, Eiji

    1999-01-01

    A 39-year-old man with acromegaly exhibited locking of metacarpophalangeal (MCP) joints of both index fingers. Large osteophytes were found at the metacarpal heads by radiography and computerized tomography (CT). Magnetic resonance (MR) images revealed hypertrophy of volar plates. We suggest that these characteristic acromegalic features caused locking of MCP joints. Surgery was required on one of the joints to release the locking. (orig.)

  20. Acoustically Generated Flows in Flexural Plate Wave Sensors: a Multifield Analysis

    Science.gov (United States)

    Sayar, Ersin; Farouk, Bakhtier

    2011-11-01

    Acoustically excited flows in a microchannel flexural plate wave device are explored numerically with a coupled solid-fluid mechanics model. The device can be exploited to integrate micropumps with microfluidic chips. A comprehensive understanding of the device requires the development of coupled two or three-dimensional fluid structure interactive (FSI) models. The channel walls are composed of layers of ZnO, Si3N4 and Al. An isothermal equation of state for the fluid (water) is employed. The flexural motions of the channel walls and the resulting flowfields are solved simultaneously. A parametric analysis is performed by varying the values of the driving frequency, voltage of the electrical signal and the channel height. The time averaged axial velocity is found to be proportional to the square of the wave amplitude. The present approach is superior to the method of successive approximations where the solid-liquid coupling is weak.

  1. Recent advances in flat plate photovoltaic/thermal (PV/T) solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Adnan; Othman, Mohd Yusof; Ruslan, Mohd Hafidz; Mat, Sohif; Sopian, Kamaruzzaman [Solar Energy Research Institute Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor (Malaysia)

    2011-01-15

    Flat plate photovoltaic/thermal (PV/T) solar collector produces both thermal energy and electricity simultaneously. This paper presents the state-of-the-art on flat plate PV/T collector classification, design and performance evaluation of water, air and combination of water and/or air based. This review also covers the future development of flat plate PV/T solar collector on building integrated photovoltaic (BIPV) and building integrated photovoltaic/thermal (BIPVT) applications. Different designs feature and performance of flat plate PV/T solar collectors have been compared and discussed. Future research and development (R and D) works have been elaborated. The tube and sheet design is the simplest and easiest to be manufactured, even though, the efficiency is 2% lower compared to other types of collectors such as, channel, free flow and two-absorber. It is clear from the review that for both air and water based PV/T solar collectors, the important key factors that influenced the efficiency of the system are the area where the collector covered, the number of passes and the gap between the absorber collector and solar cells. From the literature review, it is obvious that the flat plate PV/T solar collector is an alternative promising system for low-energy applications in residential, industrial and commercial buildings. Other possible areas for the future works of BIPVT are also mentioned. (author)

  2. Experimental investigation of thermal limits in parallel plate configuration for the future material testing reactor (JHR)

    International Nuclear Information System (INIS)

    Brigitte Noel

    2005-01-01

    Full text of publication follows: The design of the future material testing reactor, named Jules Horowitz Reactor and dedicated to technological irradiations, will allow very high performances. The JHR will be cooled and moderated by light water. The preliminary core of JHR consists of 46 assemblies, arranged in a triangular lattice inside a rectangular aluminium matrix. It is boarded on two sides by a beryllium reflector. The other two sides are left free in order to introduce mobile irradiation devices. The JHR assembly would be composed of 3 x 6 cylindrical fuel plates maintained by 3 stiffeners. The external diameter of the assembly is close to 8 cm with a 600 mm heated length, coolant channels having a 1.8 mm gap width. The JHR core must be designed to accommodate high power densities using a high coolant mass flux and sub-cooling level at moderate pressure. The JHR core configuration with multi-channels is subject to a potential excursive instability, called flow redistribution, and is distinguished from a true critical heat flux which would occur at a fixed channel flow rate. At thermal-hydraulic conditions applicable to the JHR, the availability of experimental data for both flow redistribution and CHF is very limited. Consequently, a thermal-hydraulic test facility (SULTAN-RJH) was designed and built in CEA-Grenoble to simulate a full-length coolant sub-channel representative of the JHR core, allowing determination of both thermal limits under relevant thermal hydraulics conditions. The SULTAN-RJH test section simulates a single sub-channel in the JHR core with a cross section corresponding to a mean span (∼50 mm) that has a full reactor length (600 mm), the same flow channel gap (1.5 mm) and Inconel plates of 1 mm thickness. The tests with light water flowing vertically upward will investigate a heat flux range of 0-7 MW/m 2 , velocity range of 0.6-18 m/s, exit pressure range of 0.2-1.0 MPa and inlet temperature range of 25-180 deg. C. The test section

  3. Observation of a spark channel generated in water with shock wave assistance in plate-to-plate electrode configuration

    Energy Technology Data Exchange (ETDEWEB)

    Stelmashuk, V., E-mail: vitalij@ipp.cas.cz [Institute of Plasma Physics, Za Slovankou 3, 182 00 Prague 8 (Czech Republic)

    2014-01-15

    When a high voltage pulse with an amplitude of 30 kV is applied to a pair of disk electrodes at a time when a shock wave is passing between them, an electrical spark is generated. The dynamic changes in the spark morphology are studied here using a high-speed framing camera. The primary result of this work is the provision of experimental evidence of plasma instability that was observed in the channel of the electric spark.

  4. Prolongamento da vida pós-colheita de bananas-maçã submetidas ao 1-metilciclopropeno (1-MCP - qualidade sensorial e física Extension of postharvest life of 'Apple1 banana subjected to1-methylcyclopropene (1-MCP - sensory and physical quality

    Directory of Open Access Journals (Sweden)

    Ana Carla Marques Pinheiro

    2010-03-01

    Full Text Available Objetivou-se avaliar o efeito do 1-metilciclopropeno (1-MCP sobre a qualidade e extensão da vida pós-colheita de bananas-maçã. Frutas no grau 2 de coloração da casca foram tratadas com 50 nL.L-1 de 1-MCP durante 0 (controle, 6, 9, 12 e 24 horas. Posteriormente, foram armazenadas sob condição ambiente: 22± 2 ºC 85± 5% UR. Avaliaram-se as características sensoriais: aparência dos frutos no grau 4 (frutos mais verdes que amarelos e grau 7 (frutos amarelos com pontuações marrons de coloração da casca; descasque, aroma, sabor, firmeza da polpa e aspecto global nos frutos no grau 7, utilizando-se um teste de aceitabilidade através de escala hedônica de 9 pontos; e ainda a intenção de compra nos frutos nos graus 4 e 7, através de escala de 5 pontos. Avaliou-se também, visualmente, a extensão da vida pós-colheita, e, instrumentalmente, a coloração da casca e firmeza da polpa. Conclui-se que a aplicação de 50 nL.L-1 por um período de 12 horas é a mais adequada, pois promove extensão na vida pós-colheita de bananas-maçã, armazenadas em temperatura ambiente, em aproximadamente 11 dias, sem alterar a qualidade sensorial, a intenção de compra, coloração da casca e firmeza dos frutos quando maduros, comparados ao controle.The objective of this work was to evaluate the effect of 1-methylcyclopropene (1-MCP on the quality and extension of postharvest life of 'Apple1 banana. The fruit, at degree 2 of peel color was treated with 50 nL.L-1 of 1-MCP for 0 (control, 6, 9, 12 and 24 hours. Next, It was stored at room temperature: 22± 2 ºC 85± 5 per cent RH. The following sensory characteristics were evaluated: appearance of the fruit at degree 4 (greener than yellow and degree 7 (yellow with brown spots of peel color; peeling, aroma, flavor, firmness of pulp and global aspect of the fruit at degree 7, using a test of acceptability using the 9-point hedonic scale and also the intention of buying the fruit at degrees 4 and 7

  5. Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hall, G. N., E-mail: hall98@llnl.gov; Izumi, N.; Landen, O. L.; Tommasini, R.; Holder, J. P.; Hargrove, D.; Bradley, D. K.; Lumbard, A.; Cruz, J. G.; Piston, K.; Bell, P. M.; Carpenter, A. C.; Palmer, N. E.; Felker, B.; Rekow, V.; Allen, F. V. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550 (United States); Lee, J. J.; Romano, E. [National Security Technologies LLC, 161 S Vasco Rd., Livermore, California 94551 (United States)

    2016-11-15

    Compton radiography provides a means to measure the integrity, ρR and symmetry of the DT fuel in an inertial confinement fusion implosion near peak compression. Upcoming experiments at the National Ignition Facility will use the ARC (Advanced Radiography Capability) laser to drive backlighter sources for Compton radiography experiments and will use the newly commissioned AXIS (ARC X-ray Imaging System) instrument as the detector. AXIS uses a dual-MCP (micro-channel plate) to provide gating and high DQE at the 40–200 keV x-ray range required for Compton radiography, but introduces many effects that contribute to the spatial resolution. Experiments were performed at energies relevant to Compton radiography to begin characterization of the spatial resolution of the AXIS diagnostic.

  6. Digitizing data acquisition and time-of-flight pulse processing for ToF-ERDA

    Energy Technology Data Exchange (ETDEWEB)

    Julin, Jaakko, E-mail: jaakko.julin@jyu.fi; Sajavaara, Timo

    2016-01-01

    A versatile system to capture and analyze signals from multi channel plate (MCP) based time-of-flight detectors and ionization based energy detectors such as silicon diodes and gas ionization chambers (GIC) is introduced. The system is based on commercial digitizers and custom software. It forms a part of a ToF-ERDA spectrometer, which has to be able to detect recoil atoms of many different species and energies. Compared to the currently used analogue electronics the digitizing system provides comparable time-of-flight resolution and improved hydrogen detection efficiency, while allowing the operation of the spectrometer be studied and optimized after the measurement. The hardware, data acquisition software and digital pulse processing algorithms to suit this application are described in detail.

  7. Plasma diagnostic development and UHV testing for the ALPHA collaboration at Marquette University

    Science.gov (United States)

    Tharp, T. D.; Alpha Collaboration

    2017-10-01

    At Marquette, we are developing the next generation of nonneutral plasma diagnostics for the ALPHA experiment at CERN. ALPHA is building a new vertical experiment to test the gravitational interaction of antihydrogen with Earth. This expansion requires significant changes to the design of our plasma diagnostic suites: the next generation of tools must be able to measure plasmas from two directions, and must be capable of operating in a horizontal position. The diagnostic suite includes measurements of plasma density, shape, and temperature. The hardware used includes a MicroChannel Plate (MCP), a Faraday Cup, and an electron gun. In addition, we are building a vacuum chamber to test the viability of 3-d printed components for UHV compatibility, with target pressures of 10-10 mbar.

  8. Vascular endothelial growth factor (VEGF and monocyte chemoattractant protein (MCP-1 levels unaltered in symptomatic atherosclerotic carotid plaque patients from North India

    Directory of Open Access Journals (Sweden)

    Dheeraj eKhurana

    2013-04-01

    Full Text Available We aimed to identify the role of vascular endothelial growth factor(VEGF and monocyte chemoattractant protein(MCP-1 as a serum biomarker of symptomatic carotid atherosclerotic plaque in North Indian population. Individuals with symptomatic carotid atherosclerotic plaque have high risk of ischemic stroke. Previous studies from western countries have shown an association between VEGF and MCP-1 levels and the incidence of ischemic stroke. In this study, venous blood from 110 human subjects was collected, 57 blood samples of which were obtained from patients with carotid plaques, 38 neurological controls without carotid plaques and another 15 healthy controls who had no history of serious illness. Serum VEGF and MCP-1 levels were measured using commercially available enzyme-linked immunosorbent assay(ELISA. We also correlated the data clinically and carried out risk factor analysis based on the detailed questionnaire obtained from each patient. For risk factor analysis, a total of 70 symptomatic carotid plaque cases and equal number of age and sex matched healthy controls were analyzed. We found that serum VEGF levels in carotid plaque patients did not show any significant change when compared to either of the controls. Similarly, there was no significant upregulation of monocyte chemoattractant protein-1 in the serum of these patients. The risk factor analysis revealed that hypertension, diabetes, and physical inactivity were the main correlates of carotid atherosclerosis(p<0.05. Prevalence of patients was higher residing in urban areas as compared to rural region. We also found that patients coming from mountaineer region were relatively less vulnerable to cerebral atherosclerosis as compared to the ones residing at plain region. We conclude that the pathogenesis of carotid plaques may progress independent of these inflammatory molecules. In parallel, risk factor analysis indicates hypertension, diabetes and sedentary lifestyle as the most

  9. A novel approach to modeling plate deformations in fluid–structure interactions

    Energy Technology Data Exchange (ETDEWEB)

    Howard, T.K., E-mail: howartre@onid.oregonstate.edu [Oregon State University, Department of Nuclear Engineering & Radiation Health Physics, 116 Radiation Center, Corvallis, OR 97331 (United States); Marcum, W.R., E-mail: marcumw@engr.orst.edu [Oregon State University, Department of Nuclear Engineering & Radiation Health Physics, 116 Radiation Center, Corvallis, OR 97331 (United States); Jones, W.F. [Idaho National Laboratory, Nuclear Fuels & Materials Department, 2525 Fremont Ave., Idaho Falls, ID 83415 (United States)

    2015-11-15

    Highlights: • A new method for computing fluid structure interactions of flat plates is presented herein. • The method is validated through consideration of a single plate subject to hydraulic loading. • The model is compared against solution forms computed via ABAQUS and experimental data. • The model compares well against experimental data and the commercial computational code. - Abstract: As computational power increases, so does the desire to use computational simulations while designing fuel plates. The downside is multi-physics simulations – or more specifically, fluid–structure interactions (FSI) as addressed herein – require a larger amount of computational resources. Current simulations of a single plate can take weeks on a desktop computer, thus requiring the use of multiple servers or a cluster for FSI simulations. While computational fluid dynamic (CFD) codes coupled to computational structural mechanics (CSM) codes can provide a wealth of information regarding flow patterns, there should be some skepticism in whether or not they are the only means of achieving the desired solution. When the parameters of interest are the onset of plate collapse and the associated fluid channel velocities, coupled CFD–CSM simulations provide superfluous information. The paper provides an alternative approach to solving FSI problems using a 1-D, semi-analytical model derived from first principles. The results are compared and contrasted to the numerical and experimental work performed by Kennedy et al. (2014. Experimental Investigation of Deflection of Flat Aluminium Plates Under Variable Velocity Parallel Flow, Columbia: University of Missouri TherMec Research Group).

  10. A novel approach to modeling plate deformations in fluid–structure interactions

    International Nuclear Information System (INIS)

    Howard, T.K.; Marcum, W.R.; Jones, W.F.

    2015-01-01

    Highlights: • A new method for computing fluid structure interactions of flat plates is presented herein. • The method is validated through consideration of a single plate subject to hydraulic loading. • The model is compared against solution forms computed via ABAQUS and experimental data. • The model compares well against experimental data and the commercial computational code. - Abstract: As computational power increases, so does the desire to use computational simulations while designing fuel plates. The downside is multi-physics simulations – or more specifically, fluid–structure interactions (FSI) as addressed herein – require a larger amount of computational resources. Current simulations of a single plate can take weeks on a desktop computer, thus requiring the use of multiple servers or a cluster for FSI simulations. While computational fluid dynamic (CFD) codes coupled to computational structural mechanics (CSM) codes can provide a wealth of information regarding flow patterns, there should be some skepticism in whether or not they are the only means of achieving the desired solution. When the parameters of interest are the onset of plate collapse and the associated fluid channel velocities, coupled CFD–CSM simulations provide superfluous information. The paper provides an alternative approach to solving FSI problems using a 1-D, semi-analytical model derived from first principles. The results are compared and contrasted to the numerical and experimental work performed by Kennedy et al. (2014. Experimental Investigation of Deflection of Flat Aluminium Plates Under Variable Velocity Parallel Flow, Columbia: University of Missouri TherMec Research Group).

  11. Magnetic field effect on nanoparticles migration and heat transfer of water/alumina nanofluid in a channel

    Energy Technology Data Exchange (ETDEWEB)

    Malvandi, A., E-mail: amirmalvandi@aut.ac.ir [Department of Mechanical Engineering, Amirkabir University of Technology (Tehran Polytechnic), 424 Hafez Avenue, Tehran (Iran, Islamic Republic of); Ganji, D.D., E-mail: ddg_davood@yahoo.com [Mechanical Engineering Department, Babol Noshirvani University of Technology, Babol (Iran, Islamic Republic of)

    2014-08-01

    The present study is a theoretical investigation of the laminar flow and convective heat transfer of water/alumina nanofluid inside a parallel-plate channel in the presence of a uniform magnetic field. A modified two-component, four-equation, nonhomogeneous equilibrium model was employed for the alumina/water nanofluid, which fully accounted for the effect of the nanoparticle volume fraction distribution. The no-slip condition of the fluid–solid interface is abandoned in favor of a slip condition which appropriately represents the non-equilibrium region near the interface at micro/nano channels. The results obtained indicated that nanoparticles move from the heated walls (nanoparticles depletion) toward the core region of the channel (nanoparticles accumulation) and construct a non-uniform nanoparticles distribution. Moreover, in the presence of the magnetic field, the near wall velocity gradients increase, enhancing the slip velocity and thus the heat transfer rate and pressure drop increase. - Highlights: • Force convection of alumina/water nanofluid inside a parallel-plate channel. • Magnetic field effects on nanoparticles' migration. • Effects of Brownian motion and thermophoresis diffusivities on nanoparticle migration. • Different mechanisms of heat transfer rate based on nanoparticles' diameter.

  12. The interference between two flat plates normal to a stream in staggered arrangement, 1

    International Nuclear Information System (INIS)

    Hirano, Kimitaka; Kawashima, Akira; Ohsako, Hideyuki.

    1983-01-01

    The clarification of the mutual interference characteristics between the bodies with sharp corners, such as flat plates and rectangular prisms placed perpendicularly to flow, is a fundamental and important problem. But it has not yet been sufficiently clarified. In flat plates, the points of breaking away do not move, a large breaking away region is in the wake, and the thickness is very thin in the direction of main flow. Moreover, a moment arises around the center of flat plates. In this study, a new parameter expressing the influence of channel walls on a single flat plate in the measuring part of two-dimensional wind tunnel experiment was proposed. The change of steady drag coefficient and Strouhal number corresponding to the series and parallel arrangements of two plates was clarified, and the patterns of the mutual interference were classified by using the results of visualizing flow in a circulation tank together. By the experimental results in the widely changed staggered arrangements, the isodrag contour diagram and isomoment contour diagram were drawn, and the general characteristics of mutual interference related to steady drag and moment were clarified. The experimental setup and method and the results are reported. (Kako, I.)

  13. Design and fabrication of prototype 6×6 cm2 microchannel plate photodetector with bialkali photocathode for fast timing applications

    International Nuclear Information System (INIS)

    Xie, Junqi; Byrum, Karen; Demarteau, Marcel; Gregar, Joseph; May, Edward; Virgo, Mathew; Wagner, Robert; Walters, Dean; Wang, Jingbo; Xia, Lei; Zhao, Huyue

    2015-01-01

    Planar microchannel plate-based photodetectors with a bialkali photocathode are able to achieve photon detection with very good time and position resolution. A 6×6 cm 2 photodetector production facility was designed and built at Argonne National Laboratory. Small form-factor MCP-based photodetectors completely constructed out of glass were designed and prototypes were successfully fabricated. Knudsen effusion cells were incorporated in the photocathode growth chamber to achieve uniform and high quantum efficiency photocathodes. The thin film uniformity was simulated and measured for an antimony film deposition, showing uniformity of better than 10%. Several prototype devices with bialkali photocathodes have been fabricated with the described system and their characteristics were evaluated in the large signal (multi-PE) limit. A typical prototype device exhibits time-of-flight resolution of ~27 psec and differential time resolution of ~9 psec, corresponding to spatial resolution of ~0.65 mm

  14. Radiation shielding plate

    International Nuclear Information System (INIS)

    Kobayashi, Torakichi; Sugawara, Takeo.

    1983-01-01

    Purpose: To reduce the weight and stabilize the configuration of a radiation shielding plate which is used in close contact with an object to be irradiated with radiation rays. Constitution: The radiation shielding plate comprises a substrate made of lead glass and a metallic lead coating on the surface of the substrate by means of plating, vapor deposition or the like. Apertures for permeating radiation rays are formed to the radiation shielding plate. Since the shielding plate is based on a lead glass plate, a sufficient mechanical strength can be obtained with a thinner structure as compared with the conventional plate made of metallic lead. Accordingly, if the shielding plate is disposed on a soft object to be irradiated with radiation rays, the object and the plate itself less deform to obtain a radiation irradiation pattern with distinct edges. (Moriyama, K.)

  15. Production of Fission Product 99Mo using High-Enriched Uranium Plates in Polish Nuclear Research Reactor MARIA: Technology and Neutronic Analysis

    Directory of Open Access Journals (Sweden)

    Jaroszewicz Janusz

    2014-07-01

    Full Text Available The main objective of 235U irradiation is to obtain the 99mTc isotope, which is widely used in the domain of medical diagnostics. The decisive factor determining its availability, despite its short lifetime, is a reaction of radioactive decay of 99Mo into 99mTc. One of the possible sources of molybdenum can be achieved in course of the 235U fission reaction. The paper presents activities and the calculation results obtained upon the feasibility study on irradiation of 235U targets for production of 99Mo in the MARIA research reactor. Neutronic calculations and analyses were performed to estimate the fission products activity for uranium plates irradiated in the reactor. Results of dummy targets irradiation as well as irradiation uranium plates have been presented. The new technology obtaining 99Mo is based on irradiation of high-enriched uranium plates in standard reactor fuel channel and calculation of the current fission power generation. Measurements of temperatures and the coolant flow in the molybdenum installation carried out in reactor SAREMA system give online information about the current fission power generated in uranium targets. The corrective factors were taken into account as the heat generation from gamma radiation from neighbouring fuel elements as well as heat exchange between channels and the reactor pool. The factors were determined by calibration measurements conducted with aluminium mock-up of uranium plates. Calculations of fuel channel by means of REBUS code with fine mesh structure and libraries calculated by means of WIMS-ANL code were performed.

  16. Development of sub-nanosecond, high gain structures for time-of-flight ring imaging in large area detectors

    International Nuclear Information System (INIS)

    Wetstein, Matthew

    2011-01-01

    Microchannel plate photomultiplier tubes (MCPs) are compact, imaging detectors, capable of micron-level spatial imaging and timing measurements with resolutions below 10 ps. Conventional fabrication methods are too expensive for making MCPs in the quantities and sizes necessary for typical HEP applications, such as time-of-flight ring-imaging Cherenkov detectors (TOF-RICH) or water Cherenkov-based neutrino experiments. The Large Area Picosecond Photodetector Collaboration (LAPPD) is developing new, commercializable methods to fabricate 20 cm 2 thin planar MCPs at costs comparable to those of traditional photo-multiplier tubes. Transmission-line readout with waveform sampling on both ends of each line allows the efficient coverage of large areas while maintaining excellent time and space resolution. Rather than fabricating channel plates from active, high secondary electron emission materials, we produce plates from passive substrates, and coat them using atomic layer deposition (ALD), a well established industrial batch process. In addition to possible reductions in cost and conditioning time, this allows greater control to optimize the composition of active materials for performance. We present details of the MCP fabrication method, preliminary results from testing and characterization facilities, and possible HEP applications.

  17. Plating on difficult-to-plate metals: what's new

    International Nuclear Information System (INIS)

    Wiesner, H.J.

    1980-01-01

    Some of the changes since 1970 in procedures for plating on such materials as titanium, molybdenum, silicon, aluminum, and gallium arsenide are summarized. While basic procedures for plating some of these materials were developed as many as 30 to 40 years ago, changes in the end uses of the plated products have necessitated new plating processes. In some cases, vacuum techniques - such as ion bombardment, ion implantation, and vacuum metallization - have been introduced to improve the adhesion of electrodeposits. In other cases, these techniques have been used to deposit materials upon which electrodeposits are required

  18. Effect of plate shapes in orifice plate type flowmeters

    International Nuclear Information System (INIS)

    Moeller, S.V.

    1984-01-01

    The study of unusual plate shapes in orifice plate type flowmeters is presented, with a view to providing data for the substitution of the plate with one centered circular orifice in those applications where its use is not possible. For this purpose, six pairs of plates with different forms, with and without chamfered edges, were made and tested in a closed water loop. Results show that, generally, the use of chamfers improves the results and, in the case of perforated and slotlike orificed plates, the narrow-ness of the fluid passage tends to make unnecessary its use. (Author) [pt

  19. Screen Channel Liquid Acquisition Device Outflow Tests in Liquid Hydrogen

    Science.gov (United States)

    Hartwig, Jason W.; Chato, David J.; McQuillen, J. B.; Vera, J.; Kudlac, M. T.; Quinn, F. D.

    2013-01-01

    This paper presents experimental design and test results of the recently concluded 1-g inverted vertical outflow testing of two 325x2300 full scale liquid acquisition device (LAD) channels in liquid hydrogen (LH2). One of the channels had a perforated plate and internal cooling from a thermodynamic vent system (TVS) to enhance performance. The LADs were mounted in a tank to simulate 1-g outflow over a wide range of LH2 temperatures (20.3 - 24.2 K), pressures (100 - 350 kPa), and flow rates (0.010 - 0.055 kg/s). Results indicate that the breakdown point is dominated by liquid temperature, with a second order dependence on mass flow rate through the LAD. The best performance is always achieved in the coldest liquid states for both channels, consistent with bubble point theory. Higher flow rates cause the standard channel to break down relatively earlier than the TVS cooled channel. Both the internal TVS heat exchanger and subcooling the liquid in the propellant tank are shown to significantly improve LAD performance.

  20. Conceptual design on structure and cooling channel of ITER upper port plug

    International Nuclear Information System (INIS)

    Pak, Sunil; Lee, Hyeon Gon; Jung, Ki Jung; Walker, C.; Kim, Doo Gi; Choi, Kwang Suk; Eo, Sang Gon

    2007-01-01

    This study has performed conceptual design on structure and cooling channel for the upper port plug of the International Thermonuclear Experimental Reactor (ITER), in which electron cyclotron heating (ECH) launcher and various diagnostic modules will be installed with the same structure. There are twelve diagnostic plugs and four ECH plugs at the upper port in ITER Tokamak. The use of the same port plug structure is beneficial for installation of diagnostic modules and ECH launcher from the viewpoint of cost reduction and simple RH maintenance. The diagnostic modules have rectangular cross-section and ECH modules have trapezoidal crosssection with the lower part wider. Here was suggested the bolt-jointed common structure of inverted-U shape beam and bottom plate, where the diagnostic and ECH modules are installed onto the bottom plate and then the assembly is bolted to the inverted-U beam from the bottom. The common structure of Inverted-U type was evaluated by considering several aspects, such as installation, remote handling (RH) maintenance, cooling line connection, manufacturing, and structural stiffness. For the inverted-U port plug structure developed here, this paper proposed a network of water channel for cooling and baking. Pressurized water as working fluid has to be supplied into the whole port plug. It consists of the structure, diagnostic/shielding modules fixed onto the bottom plate, and the blanket shield module (BSM) attached to the front. The internal water ways for these three components were designed in the direction that would not only minimize the RH connections, flow restrictors, and the length of water-vacuum welding, but also make the welding reliable. Independent coolant loops were composed for three parts of the structure, BSM, and diagnostic/shielding modules with bottom plate. These loops, therefore, make it possible to perform the leakage test for each one separately. Finally hydraulic analysis has been performed with ANSYS in order to

  1. Plating laboratory

    International Nuclear Information System (INIS)

    Seamster, A.G.; Weitkamp, W.G.

    1984-01-01

    The lead plating of the prototype resonator has been conducted entirely in the plating laboratory at SUNY Stony Brook. Because of the considerable cost and inconvenience in transporting personnel and materials to and from Stony Brook, it is clearly impractical to plate all the resonators there. Furthermore, the high-beta resonator cannot be accommodated at Stony Brook without modifying the set up there. Consequently the authors are constructing a plating lab in-house

  2. Visualization experimental investigation on long stripe coherent structure in small-scale rectangular channel

    International Nuclear Information System (INIS)

    Su Jiqiang; Sun Zhongning; Fan Guangming; Wang Shiming

    2013-01-01

    The long stripe coherent structure of the turbulent boundary layer in a small- scale vertical rectangular channel was observed by using hydrogen bubble flow trace visualization technique. The statistical properties of the long stripe in the experimental channel boundary layer were compared with that in the smooth flat plate boundary layer. The pitch characteristics were explained by the formation mechanism of the long stripe. It was analyzed that how the change of y + affected the distribution of the long stripe. In addition, the frequency characteristics of the long stripe were also investigated, and the correlation of the long stripe frequency in such a flow channel was obtained. (authors)

  3. Reverse blocking characteristics and mechanisms in Schottky-drain AlGaN/GaN HEMT with a drain field plate and floating field plates

    Science.gov (United States)

    Wei, Mao; Wei-Bo, She; Cui, Yang; Jin-Feng, Zhang; Xue-Feng, Zheng; Chong, Wang; Yue, Hao

    2016-01-01

    In this paper, a novel AlGaN/GaN HEMT with a Schottky drain and a compound field plate (SD-CFP HEMT) is presented for the purpose of better reverse blocking capability. The compound field plate (CFP) consists of a drain field plate (DFP) and several floating field plates (FFPs). The physical mechanisms of the CFP to improve the reverse breakdown voltage and to modulate the distributions of channel electric field and potential are investigated by two-dimensional numerical simulations with Silvaco-ATLAS. Compared with the HEMT with a Schottky drain (SD HEMT) and the HEMT with a Schottky drain and a DFP (SD-FP HEMT), the superiorities of SD-CFP HEMT lie in the continuous improvement of the reverse breakdown voltage by increasing the number of FFPs and in the same fabrication procedure as the SD-FP HEMT. Two useful optimization laws for the SD-CFP HEMTs are found and extracted from simulation results. The relationship between the number of the FFPs and the reverse breakdown voltage as well as the FP efficiency in SD-CFP HEMTs are discussed. The results in this paper demonstrate a great potential of CFP for enhancing the reverse blocking ability in AlGaN/GaN HEMT and may be of great value and significance in the design and actual manufacture of SD-CFP HEMTs. Project supported by the National Natural Science Foundation of China (Grant Nos. 61204085, 61334002, 61306017, 61474091, 61574112, and 61574110).

  4. Ligamentous and capsular injuries to the metacarpophalangeal joints of the hand.

    Science.gov (United States)

    Shah, Smiresh Suresh; Techy, Fernando; Mejia, Alfonso; Gonzalez, Mark H

    2012-01-01

    The mechanism of dorsal dislocation of the metacarpophalangeal (MCP) joint is with forced hyperextension of the joint and the main structure injured is the volar plate. A simple dislocation can be reduced by closed means whereas a complex dislocation cannot. Care must be taken not to put traction across the joint, which may cause the volar plate to slip into the joint, converting a simple dislocation into a complex dislocation. Volar dislocations are rare and mainly treated nonoperatively. Sagittal band injuries can be treated with extension splinting or surgical management with direct repair or reconstruction. A locked MCP joint can usually be treated with closed manipulation. This article discusses these injuries and management options.

  5. Hall effects on unsteady MHD reactive flow of second grade fluid through porous medium in a rotating parallel plate channel

    Science.gov (United States)

    Krishna, M. Veera; Swarnalathamma, B. V.

    2017-07-01

    We considered the transient MHD flow of a reactive second grade fluid through porous medium between two infinitely long horizontal parallel plates when one of the plate is set into uniform accelerated motion in the presence of a uniform transverse magnetic field under Arrhenius reaction rate. The governing equations are solved by Laplace transform technique. The effects of the pertinent parameters on the velocity, temperature are discussed in detail. The shear stress and Nusselt number at the plates are also obtained analytically and computationally discussed with reference to governing parameters.

  6. Predicting the onset of dynamic instability of a cylindrical plate under axial flow conditions

    Energy Technology Data Exchange (ETDEWEB)

    Marcum, W.R., E-mail: marcumw@engr.orst.edu [Oregon State University, Department of Nuclear Engineering and Radiation Health Physics, 116 Radiation Center, Corvallis, OR 97330 (United States); Woods, B.G. [Oregon State University, Department of Nuclear Engineering and Radiation Health Physics, 116 Radiation Center, Corvallis, OR 97330 (United States)

    2012-09-15

    Highlights: Black-Right-Pointing-Pointer A semi-numerical flow induced vibration model is developed of a cylindrical plate. Black-Right-Pointing-Pointer Test case results are presented and agree well with previous studies data. Black-Right-Pointing-Pointer The model identifies a relationship between forces and the plate natural frequency. - Abstract: The dynamic mechanical stability of a single cylindrical plate under flow conditions is considered herein. Numerous plate-type research reactors such as the Advanced Test Reactor (ATR) located at the Idaho National Laboratory (INL) comprise fuel elements which contain arrays of concentrically aligned cylindrical plates. Several of these reactors are licensed to operate at extreme heat fluxes; as a corollary their hydraulic designs require large flow rates sufficient to remove this heat. These flow rates may reach superficial velocities upwards of 15 m/s through individual flow channels. Given that fuel plates typically found in such research reactors are relatively long ({approx}1.2573 m), wide ({approx}0.1397 m), and extremely thin ({approx}0.00127 m) concern is drawn toward the susceptibility of flow induced vibration (FIV). In an attempt to gain a more comprehensive understanding toward the dynamic mechanical limit of stability of cylindrical plates, a FIV model was developed using semi-numerical methods. The FIV model was developed in two separate modules; a plate stability module, and a flow module. These modules were then coupled together to produce a FIV model. In this study, a set of test cases are presented on the plate stability module under free vibration conditions, comparing well against known available information from previous studies. Results are similarly presented on the flow module and compared against a RELAP5-3D model. Lastly, results of these coupled modules are presented and discussion is given toward the relationship between plate natural frequency, geometry, and plate membrane pressures.

  7. Plate heat exchanger - inertia flywheel performance in loss of flow transient

    International Nuclear Information System (INIS)

    Abou-El-Maaty, Talal; Abd-El-Hady, Amr

    2009-01-01

    One of the most versatile types of heat exchangers used is the plate heat exchanger. It has principal advantages over other heat exchangers in that plates can be added and/or removed easily in order to change the area available for heat transfer and therefore its overall performance. The cooling systems of Egypt's second research reactor (ETRR 2) use this type of heat exchanger for cooling purposes in its primary core cooling and pool cooling systems. In addition to the change in the number of heat exchanger cooling channels, the effect of changing the amount of mass flow rate on the heat exchanger performance is an important issues in this study. The inertia flywheel mounted on the primary core cooling system pump with the plate heat exchanger plays an important role in the case of loss of flow transients. The PARET code is used to simulate the effect of loss of flow transients on the reactor core. Hence, the core outlet temperature with the pump-flywheel flow coast down is fed into the plate heat exchanger model developed to estimate the total energy transferred to the cooling tower, the primary side heat exchanger temperature variation, the transmitted heat exchanger power, and the heat exchanger effectiveness. In addition, the pressure drop in both, the primary side and secondary side of the plate heat exchanger is calculated in all simulated transients because their values have limits beyond which the heat exchanger is useless. (orig.)

  8. Strontium-Substituted Bioceramics Particles: A New Way to Modulate MCP-1 and Gro-α Production by Human Primary Osteoblastic Cells

    Directory of Open Access Journals (Sweden)

    Julien Braux

    2016-12-01

    Full Text Available Background: To avoid morbidity and limited availability associated with autografts, synthetic calcium phosphate (CaP ceramics were extensively developed and used as bone filling materials. Controlling their induced-inflammatory response nevertheless remained a major concern. Strontium-containing CaP ceramics were recently demonstrated for impacting cytokines’ secretion pattern of human primary monocytes. The present study focuses on the ability of strontium-containing CaP to control the human primary bone cell production of two major inflammatory and pro-osteoclastogenic mediators, namely MCP-1 and Gro-α, in response to ceramics particles. Methods: This in vitro study was performed using human primary osteoblasts in which their response to ceramics was evaluated by PCR arrays, antibody arrays were used for screening and real-time PCR and ELISA for more focused analyses. Results: Study of mRNA and protein expression highlights that human primary bone cells are able to produce these inflammatory mediators and reveal that the adjunction of CaP in the culture medium leads to their enhanced production. Importantly, the current work determines the down-regulating effect of strontium-substituted CaP on MCP-1 and Gro-α production. Conclusion: Our findings point out a new capability of strontium to modulate human primary bone cells’ communication with the immune system.

  9. Energy and exergy analysis of a new flat-plate solar air heater having different obstacles on absorber plates

    International Nuclear Information System (INIS)

    Akpinar, Ebru Kavak; Kocyigit, Fatih

    2010-01-01

    This study experimentally investigates performance analysis of a new flat-plate solar air heater (SAH) with several obstacles (Type I, Type II, Type III) and without obstacles (Type IV). Experiments were performed for two air mass flow rates of 0.0074 and 0.0052 kg/s. The first and second laws of efficiencies were determined for SAHs and comparisons were made among them. The values of first law efficiency varied between 20% and 82%. The values of second law efficiency changed from 8.32% to 44.00%. The highest efficiency were determined for the SAH with Type II absorbent plate in flow channel duct for all operating conditions, whereas the lowest values were obtained for the SAH without obstacles (Type IV). The results showed that the efficiency of the solar air collectors depends significantly on the solar radiation, surface geometry of the collectors and extension of the air flow line. The largest irreversibility was occurring at the SAH without obstacles (Type IV) collector in which collector efficiency is smallest. At the end of this study, the energy and exergy relationships are delivered for different SAHs.

  10. Genetic polymorphisms of RANTES, IL1-A, MCP-1 and TNF-A genes in patients with prostate cancer

    International Nuclear Information System (INIS)

    Sáenz-López, Pablo; Carretero, Rafael; Cózar, José Manuel; Romero, José Maria; Canton, Julia; Vilchez, José Ramón; Tallada, Miguel; Garrido, Federico; Ruiz-Cabello, Francisco

    2008-01-01

    Inflammation has been implicated as an etiological factor in several human cancers, including prostate cancer. Allelic variants of the genes involved in inflammatory pathways are logical candidates as genetic determinants of prostate cancer risk. The purpose of this study was to investigate whether single nucleotide polymorphisms of genes that lead to increased levels of pro-inflammatory cytokines and chemokines are associated with an increased prostate cancer risk. A case-control study design was used to test the association between prostate cancer risk and the polymorphisms TNF-A-308 A/G (rs 1800629), RANTES-403 G/A (rs 2107538), IL1-A-889 C/T (rs 1800587) and MCP-1 2518 G/A (rs 1024611) in 296 patients diagnosed with prostate cancer and in 311 healthy controls from the same area. Diagnosis of prostate cancer was significantly associated with TNF-A GA + AA genotype (OR, 1.61; 95% CI, 1.09–2.64) and RANTES GA + AA genotype (OR, 1.44; 95% CI, 1.09–2.38). A alleles in TNF-A and RANTES influenced prostate cancer susceptibility and acted independently of each other in these subjects. No epistatic effect was found for the combination of different polymorphisms studied. Finally, no overall association was found between prostate cancer risk and IL1-A or MCP-1 polymorphisms. Our results and previously published findings on genes associated with innate immunity support the hypothesis that polymorphisms in proinflammatory genes may be important in prostate cancer development

  11. Create Your Plate

    Medline Plus

    Full Text Available ... Plate Share Create Your Plate ! Share: Seven Simple Steps to Create Your Plate It's simple and effective ... foods within each food category. Try these seven steps to get started: Using your dinner plate, put ...

  12. Connection of leak detectors for duplex tube plates of modular steam generator

    International Nuclear Information System (INIS)

    Banovec, J.; Konarik, M.; Vytopil, O.

    1985-01-01

    The sensors are connected to common line and column conductors. This connection significantly reduces the number of evaluation points and thus also the required number of evaluation unit channels. The reliability of the instrument is increased by each sensor being connected to two separate group conductors. Even upon failure of one of the conductors, the group of tube plates can be identified where a leak occurred. (J.B.)

  13. Predictions of the effect of stratification on superimposed forced and free convection between vertical parallel plates for various boundary conditions

    International Nuclear Information System (INIS)

    Cowan, G.H.; Irvine, T.J. Jr.; Quarini, G.L.

    1983-01-01

    The velocity and temperature equations for laminar buoyancy and forced convection flows between vertical flat parallel plates are presented. The thermal boundary conditions on the plate define the buoyancy driven field, while the channel Reynolds number defines the forced flow field. Specific examples relating to tall narrow channels with laminar convention and to closed high ratio cavities (as may be found in the proposed active and passive insulation systems for sodium cooled fast reactors) are presented. The analysis is limited to the laminar flow regimes, whilst some reactor situations are likely to be turbulent, hence a proposal for a simple extension of this analysis to the turbulent regime is made. It is shown how the analysis can be made to apply to fluids of various Prandtl numbers. (author)

  14. Twenty-channel high-voltage pulse generators

    International Nuclear Information System (INIS)

    Anan'in, P.S.; Kashirin, A.P.

    1980-01-01

    A 20-channel high-voltage pulse generator operating with a mismatched load is described. The generator contains shaping lines 20 m long made of coaxial cable, a trigatron-type discharged, and isolating plates. The channel characteristic impedance is 50 Ohm. The maximum pulse amplitude is up to 15 kV on a high-resistance load and 7.5 kV on a matched one. The pulse duration is 100 ns at a pulse rise time of 12 ns, the delay introduced by the generator is 200 +-2.5 ns. Provision is made in the control circuit for compensation of the shaped pulse and separation of a pulse reflected from the load. The reflected pulse shape and amplitude characterize load parameters. Generator tests proved its high operational reliability (after 10 5 operations no significant changes in generator performances have been observed). The generator is intended for filmless data output from spark chambers

  15. Fast leak in channel H9

    International Nuclear Information System (INIS)

    Bauer, E.

    1987-01-01

    The loss of seal of the H9 channel in vacuum, freeing the entire cross section of the front part, leads to a fast leak that progresses rapidly. The effect of depressurizing the reflector can leads to shutdown of the shutdown rod pumps. The source changer associated with the channel fills completely before the valve closes. All of the leak water remains contained within the source changer containment. After the valves open, cooling of the fuel element is handled by natural convection, requiring a reversal of the flow between the plates. This changeover, which takes place at a relatively low pressure level, could lead to local boiling in the fuel element. Consequently, irreversible transformations cannot be excluded as possibilities for the fuel element and even for the control rod. Subsequently, the can is refilled with heavy water with establishment of the usual pressure levels

  16. Analysis of the modulation mechanisms of the electric field and breakdown performance in AlGaN/GaN HEMT with a T-shaped field-plate

    International Nuclear Information System (INIS)

    Mao Wei; Fan Ju-Sheng; Du Ming; Zhang Jin-Feng; Zheng Xue-Feng; Wang Chong; Ma Xiao-Hua; Zhang Jin-Cheng; Hao Yue

    2016-01-01

    A novel AlGaN/GaN high electron mobility transistor (HEMT) with a source-connected T-shaped field-plate (ST-FP HEMT) is proposed for the first time in this paper. The source-connected T-shaped field-plate (ST-FP) is composed of a source-connected field-plate (S-FP) and a trench metal. The physical intrinsic mechanisms of the ST-FP to improve the breakdown voltage and the FP efficiency and to modulate the distributions of channel electric field and potential are studied in detail by means of two-dimensional numerical simulations with Silvaco-ATLAS. A comparison to the HEMT and the HEMT with an S-FP (S-FP HEMT) shows that the ST-FP HEMT could achieve a broader and more uniform channel electric field distribution with the help of a trench metal, which could increase the breakdown voltage and the FP efficiency remarkably. In addition, the relationship between the structure of the ST-FP, the channel electric field, the breakdown voltage as well as the FP efficiency in ST-FP HEMT is analyzed. These results could open up a new effective method to fabricate high voltage power devices for the power electronic applications. (paper)

  17. Heat transfer characteristics in the channel of a finned absorber solar collector; Caracteristicas da transferencia de calor no canal de um coletor solar de absorvedor aletado

    Energy Technology Data Exchange (ETDEWEB)

    Saboya, Sergio Mourao [Centro Tecnico Aeroespacial, Sao Jose dos Campos, SP (Brazil). Inst. Tecnologico de Aeronautica; Saboya, Francisco Eduardo Mourao [Universidade Federal Fluminense, Niteroi, RJ (Brazil)]. E-mails: saboya@mec.ita.cta.br; fsaboya@mec.uff.br

    2000-07-01

    Finned absorber solar collectors are devices in which plates (fins) are fixed perpendicularly to the absorber plate. The purpose of these fins is to cause the so called 'cavity effect', lowering the collector losses. This paper studies the heat transfer that occurs in the collector channel. This analysis is done using the efficiency of the collector, which is calculated solving the system of equations that govern the collector thermal behavior, and the computation of the convection heat transfer between the fluid flowing in the channel and the absorber plate. This analysis allows the calculation of design parameters such as mass flow rate and exit bulk temperature of the fluid. (author)

  18. N-caffeoyltryptomine, a potent anti-inflammatory phenolic amide, suppressed MCP-1 expression in LPS-stimulated THP-1 cells and rats fed with a high fat diet

    Science.gov (United States)

    Monocyte chemoattractant protein-1 (MCP-1) is a well-known chemokine critically involved in the pathophysiological progression of cardiovascular diseases such as arthrosclerosis. N-caffeoyltryptamine is a phenolic amide with strong anti-inflammatory effects. Therefore, in this paper, the potential e...

  19. Paper microzone plates.

    Science.gov (United States)

    Carrilho, Emanuel; Phillips, Scott T; Vella, Sarah J; Martinez, Andres W; Whitesides, George M

    2009-08-01

    This paper describes 96- and 384-microzone plates fabricated in paper as alternatives to conventional multiwell plates fabricated in molded polymers. Paper-based plates are functionally related to plastic well plates, but they offer new capabilities. For example, paper-microzone plates are thin (approximately 180 microm), require small volumes of sample (5 microL per zone), and can be manufactured from inexpensive materials ($0.05 per plate). The paper-based plates are fabricated by patterning sheets of paper, using photolithography, into hydrophilic zones surrounded by hydrophobic polymeric barriers. This photolithography used an inexpensive formulation photoresist that allows rapid (approximately 15 min) prototyping of paper-based plates. These plates are compatible with conventional microplate readers for quantitative absorbance and fluorescence measurements. The limit of detection per zone loaded for fluorescence was 125 fmol for fluorescein isothiocyanate-labeled bovine serum albumin, and this level corresponds to 0.02 the quantity of analyte per well used to achieve comparable signal-to-noise in a 96-well plastic plate (using a solution of 25 nM labeled protein). The limits of detection for absorbance on paper was approximately 50 pmol per zone for both Coomassie Brilliant Blue and Amaranth dyes; these values were 0.4 that required for the plastic plate. Demonstration of quantitative colorimetric correlations using a scanner or camera to image the zones and to measure the intensity of color, makes it possible to conduct assays without a microplate reader.

  20. Limiting photocurrent analysis of a wide channel photoelectrochemical flow reactor

    International Nuclear Information System (INIS)

    Davis, Jonathan T; Esposito, Daniel V

    2017-01-01

    The development of efficient and scalable photoelectrochemical (PEC) reactors is of great importance for the eventual commercialization of solar fuels technology. In this study, we systematically explore the influence of convective mass transport and light intensity on the performance of a 3D-printed PEC flow cell reactor based on a wide channel, parallel plate geometry. Using this design, the limiting current density generated from the hydrogen evolution reaction at a p-Si metal–insulator–semiconductor (MIS) photocathode was investigated under varied reactant concentration, fluid velocity, and light intensity. Additionally, a simple model is introduced to predict the range of operating conditions (reactant concentration, light intensity, fluid velocity) for which the photocurrent generated in a parallel plate PEC flow cell is limited by light absorption or mass transport. This model can serve as a useful guide for the design and operation of wide-channel PEC flow reactors. The results of this study have important implications for PEC reactors operating in electrolytes with dilute reactant concentrations and/or under high light intensities where high fluid velocities are required in order to avoid operation in the mass transport-limited regime. (paper)

  1. Physical origin of selectivity in ionic channels of biological membranes.

    Science.gov (United States)

    Laio, A; Torre, V

    1999-01-01

    This paper shows that the selectivity properties of monovalent cation channels found in biological membranes can originate simply from geometrical properties of the inner core of the channel without any critical contribution from electrostatic interactions between the permeating ions and charged or polar groups. By using well-known techniques of statistical mechanics, such as the Langevin equations and Kramer theory of reaction rates, a theoretical equation is provided relating the permeability ratio PB/PA between ions A and B to simple physical properties, such as channel geometry, thermodynamics of ion hydration, and electrostatic interactions between the ion and charged (or polar) groups. Diffusive corrections and recrossing rates are also considered and evaluated. It is shown that the selectivity found in usual K+, gramicidin, Na+, cyclic nucleotide gated, and end plate channels can be explained also in the absence of any charged or polar group. If these groups are present, they significantly change the permeability ratio only if the ion at the selectivity filter is in van der Waals contact with them, otherwise these groups simply affect the channel conductance, lowering the free energy barrier of the same amount for the two ions, thus explaining why single channel conductance, as it is experimentally observed, can be very different in channels sharing the same selectivity sequence. The proposed theory also provides an estimate of channel minimum radius for K+, gramicidin, Na+, and cyclic nucleotide gated channels.

  2. Performance Study of the CMS Barrel Resistive Plate Chambers with Cosmic Rays

    CERN Document Server

    Chatrchyan, S; Sirunyan, A M; Adam, W; Arnold, B; Bergauer, H; Bergauer, T; Dragicevic, M; Eichberger, M; Erö, J; Friedl, M; Frühwirth, R; Ghete, V M; Hammer, J; Hänsel, S; Hoch, M; Hörmann, N; Hrubec, J; Jeitler, M; Kasieczka, G; Kastner, K; Krammer, M; Liko, D; Magrans de Abril, I; Mikulec, I; Mittermayr, F; Neuherz, B; Oberegger, M; Padrta, M; Pernicka, M; Rohringer, H; Schmid, S; Schöfbeck, R; Schreiner, T; Stark, R; Steininger, H; Strauss, J; Taurok, A; Teischinger, F; Themel, T; Uhl, D; Wagner, P; Waltenberger, W; Walzel, G; Widl, E; Wulz, C E; Chekhovsky, V; Dvornikov, O; Emeliantchik, I; Litomin, A; Makarenko, V; Marfin, I; Mossolov, V; Shumeiko, N; Solin, A; Stefanovitch, R; Suarez Gonzalez, J; Tikhonov, A; Fedorov, A; Karneyeu, A; Korzhik, M; Panov, V; Zuyeuski, R; Kuchinsky, P; Beaumont, W; Benucci, L; Cardaci, M; De Wolf, E A; Delmeire, E; Druzhkin, D; Hashemi, M; Janssen, X; Maes, T; Mucibello, L; Ochesanu, S; Rougny, R; Selvaggi, M; Van Haevermaet, H; Van Mechelen, P; Van Remortel, N; Adler, V; Beauceron, S; Blyweert, S; D'Hondt, J; De Weirdt, S; Devroede, O; Heyninck, J; Kalogeropoulos, A; Maes, J; Maes, M; Mozer, M U; Tavernier, S; Van Doninck, W; Van Mulders, P; Villella, I; Bouhali, O; Chabert, E C; Charaf, O; Clerbaux, B; De Lentdecker, G; Dero, V; Elgammal, S; Gay, A P R; Hammad, G H; Marage, P E; Rugovac, S; Vander Velde, C; Vanlaer, P; Wickens, J; Grunewald, M; Klein, B; Marinov, A; Ryckbosch, D; Thyssen, F; Tytgat, M; Vanelderen, L; Verwilligen, P; Basegmez, S; Bruno, G; Caudron, J; Delaere, C; Demin, P; Favart, D; Giammanco, A; Grégoire, G; Lemaitre, V; Militaru, O; Ovyn, S; Piotrzkowski, K; Quertenmont, L; Schul, N; Beliy, N; Daubie, E; Alves, G A; Pol, M E; Souza, M H G; Carvalho, W; De Jesus Damiao, D; De Oliveira Martins, C; Fonseca De Souza, S; Mundim, L; Oguri, V; Santoro, A; Silva Do Amaral, S M; Sznajder, A; Fernandez Perez Tomei, T R; Ferreira Dias, M A; Gregores, E M; Novaes, S F; Abadjiev, K; Anguelov, T; Damgov, J; Darmenov, N; Dimitrov, L; Genchev, V; Iaydjiev, P; Piperov, S; Stoykova, S; Sultanov, G; Trayanov, R; Vankov, I; Dimitrov, A; Dyulendarova, M; Kozhuharov, V; Litov, L; Marinova, E; Mateev, M; Pavlov, B; Petkov, P; Toteva, Z; Chen, G M; Chen, H S; Guan, W; Jiang, C H; Liang, D; Liu, B; Meng, X; Tao, J; Wang, J; Wang, Z; Xue, Z; Zhang, Z; Ban, Y; Cai, J; Ge, Y; Guo, S; Hu, Z; Mao, Y; Qian, S J; Teng, H; Zhu, B; Avila, C; Baquero Ruiz, M; Carrillo Montoya, C A; Gomez, A; Gomez Moreno, B; Ocampo Rios, A A; Osorio Oliveros, A F; Reyes Romero, D; Sanabria, J C; Godinovic, N; Lelas, K; Plestina, R; Polic, D; Puljak, I; Antunovic, Z; Dzelalija, M; Brigljevic, V; Duric, S; Kadija, K; Morovic, S; Fereos, R; Galanti, M; Mousa, J; Papadakis, A; Ptochos, F; Razis, P A; Tsiakkouri, D; Zinonos, Z; Hektor, A; Kadastik, M; Kannike, K; Müntel, M; Raidal, M; Rebane, L; Anttila, E; Czellar, S; Härkönen, J; Heikkinen, A; Karimäki, V; Kinnunen, R; Klem, J; Kortelainen, M J; Lampén, T; Lassila-Perini, K; Lehti, S; Lindén, T; Luukka, P; Mäenpää, T; Nysten, J; Tuominen, E; Tuominiemi, J; Ungaro, D; Wendland, L; Banzuzi, K; Korpela, A; Tuuva, T; Nedelec, P; Sillou, D; Besancon, M; Chipaux, R; Dejardin, M; Denegri, D; Descamps, J; Fabbro, B; Faure, J L; Ferri, F; Ganjour, S; Gentit, F X; Givernaud, A; Gras, P; Hamel de Monchenault, G; Jarry, P; Lemaire, M C; Locci, E; Malcles, J; Marionneau, M; Millischer, L; Rander, J; Rosowsky, A; Rousseau, D; Titov, M; Verrecchia, P; Baffioni, S; Bianchini, L; Bluj, M; Busson, P; Charlot, C; Dobrzynski, L; Granier de Cassagnac, R; Haguenauer, M; Miné, P; Paganini, P; Sirois, Y; Thiebaux, C; Zabi, A; Agram, J L; Besson, A; Bloch, D; Bodin, D; Brom, J M; Conte, E; Drouhin, F; Fontaine, J C; Gelé, D; Goerlach, U; Gross, L; Juillot, P; Le Bihan, A C; Patois, Y; Speck, J; Van Hove, P; Baty, C; Bedjidian, M; Blaha, J; Boudoul, G; Brun, H; Chanon, N; Chierici, R; Contardo, D; Depasse, P; Dupasquier, T; El Mamouni, H; Fassi, F; Fay, J; Gascon, S; Ille, B; Kurca, T; Le Grand, T; Lethuillier, M; Lumb, N; Mirabito, L; Perries, S; Vander Donckt, M; Verdier, P; Djaoshvili, N; Roinishvili, N; Roinishvili, V; Amaglobeli, N; Adolphi, R; Anagnostou, G; Brauer, R; Braunschweig, W; Edelhoff, M; Esser, H; Feld, L; Karpinski, W; Khomich, A; Klein, K; Mohr, N; Ostaptchouk, A; Pandoulas, D; Pierschel, G; Raupach, F; Schael, S; Schultz von Dratzig, A; Schwering, G; Sprenger, D; Thomas, M; Weber, M; Wittmer, B; Wlochal, M; Actis, O; Altenhöfer, G; Bender, W; Biallass, P; Erdmann, M; Fetchenhauer, G; Frangenheim, J; Hebbeker, T; Hilgers, G; Hinzmann, A; Hoepfner, K; Hof, C; Kirsch, M; Klimkovich, T; Kreuzer, P; Lanske, D; Merschmeyer, M; Meyer, A; Philipps, B; Pieta, H; Reithler, H; Schmitz, S A; Sonnenschein, L; Sowa, M; Steggemann, J; Szczesny, H; Teyssier, D; Zeidler, C; Bontenackels, M; Davids, M; Duda, M; Flügge, G; Geenen, H; Giffels, M; Haj Ahmad, W; Hermanns, T; Heydhausen, D; Kalinin, S; Kress, T; Linn, A; Nowack, A; Perchalla, L; Poettgens, M; Pooth, O; Sauerland, P; Stahl, A; Tornier, D; Zoeller, M H; Aldaya Martin, M; Behrens, U; Borras, K; Campbell, A; Castro, E; Dammann, D; Eckerlin, G; Flossdorf, A; Flucke, G; Geiser, A; Hatton, D; Hauk, J; Jung, H; Kasemann, M; Katkov, I; Kleinwort, C; Kluge, H; Knutsson, A; Kuznetsova, E; Lange, W; Lohmann, W; Mankel, R; Marienfeld, M; Meyer, A B; Miglioranzi, S; Mnich, J; Ohlerich, M; Olzem, J; Parenti, A; Rosemann, C; Schmidt, R; Schoerner-Sadenius, T; Volyanskyy, D; Wissing, C; Zeuner, W D; Autermann, C; Bechtel, F; Draeger, J; Eckstein, D; Gebbert, U; Kaschube, K; Kaussen, G; Klanner, R; Mura, B; Naumann-Emme, S; Nowak, F; Pein, U; Sander, C; Schleper, P; Schum, T; Stadie, H; Steinbrück, G; Thomsen, J; Wolf, R; Bauer, J; Blüm, P; Buege, V; Cakir, A; Chwalek, T; De Boer, W; Dierlamm, A; Dirkes, G; Feindt, M; Felzmann, U; Frey, M; Furgeri, A; Gruschke, J; Hackstein, C; Hartmann, F; Heier, S; Heinrich, M; Held, H; Hirschbuehl, D; Hoffmann, K H; Honc, S; Jung, C; Kuhr, T; Liamsuwan, T; Martschei, D; Mueller, S; Müller, Th; Neuland, M B; Niegel, M; Oberst, O; Oehler, A; Ott, J; Peiffer, T; Piparo, D; Quast, G; Rabbertz, K; Ratnikov, F; Ratnikova, N; Renz, M; Saout, C; Sartisohn, G; Scheurer, A; Schieferdecker, P; Schilling, F P; Schott, G; Simonis, H J; Stober, F M; Sturm, P; Troendle, D; Trunov, A; Wagner, W; Wagner-Kuhr, J; Zeise, M; Zhukov, V; Ziebarth, E B; Daskalakis, G; Geralis, T; Karafasoulis, K; Kyriakis, A; Loukas, D; Markou, A; Markou, C; Mavrommatis, C; Petrakou, E; Zachariadou, A; Gouskos, L; Katsas, P; Panagiotou, A; Evangelou, I; Kokkas, P; Manthos, N; Papadopoulos, I; Patras, V; Triantis, F A; Bencze, G; Boldizsar, L; Debreczeni, G; Hajdu, C; Hernath, S; Hidas, P; Horvath, D; Krajczar, K; Laszlo, A; Patay, G; Sikler, F; Toth, N; Vesztergombi, G; Beni, N; Christian, G; Imrek, J; Molnar, J; Novak, D; Palinkas, J; Szekely, G; Szillasi, Z; Tokesi, K; Veszpremi, V; Kapusi, A; Marian, G; Raics, P; Szabo, Z; Trocsanyi, Z L; Ujvari, B; Zilizi, G; Bansal, S; Bawa, H S; Beri, S B; Bhatnagar, V; Jindal, M; Kaur, M; Kaur, R; Kohli, J M; Mehta, M Z; Nishu, N; Saini, L K; Sharma, A; Singh, A; Singh, J B; Singh, S P; Ahuja, S; Arora, S; Bhattacharya, S; Chauhan, S; Choudhary, B C; Gupta, P; Jain, S; Jha, M; Kumar, A; Ranjan, K; Shivpuri, R K; Srivastava, A K; Choudhury, R K; Dutta, D; Kailas, S; Kataria, S K; Mohanty, A K; Pant, L M; Shukla, P; Topkar, A; Aziz, T; Guchait, M; Gurtu, A; Maity, M; Majumder, D; Majumder, G; Mazumdar, K; Nayak, A; Saha, A; Sudhakar, K; Banerjee, S; Dugad, S; Mondal, N K; Arfaei, H; Bakhshiansohi, H; Fahim, A; Jafari, A; Mohammadi Najafabadi, M; Moshaii, A; Paktinat Mehdiabadi, S; Rouhani, S; Safarzadeh, B; Zeinali, M; Felcini, M; Abbrescia, M; Barbone, L; Chiumarulo, F; Clemente, A; Colaleo, A; Creanza, D; Cuscela, G; De Filippis, N; De Palma, M; De Robertis, G; Donvito, G; Fedele, F; Fiore, L; Franco, M; Iaselli, G; Lacalamita, N; Loddo, F; Lusito, L; Maggi, G; Maggi, M; Manna, N; Marangelli, B; My, S; Natali, S; Nuzzo, S; Papagni, G; Piccolomo, S; Pierro, G A; Pinto, C; Pompili, A; Pugliese, G; Rajan, R; Ranieri, A; Romano, F; Roselli, G; Selvaggi, G; Shinde, Y; Silvestris, L; Tupputi, S; Zito, G; Abbiendi, G; Bacchi, W; Benvenuti, A C; Boldini, M; Bonacorsi, D; Braibant-Giacomelli, S; Cafaro, V D; Caiazza, S S; Capiluppi, P; Castro, A; Cavallo, F R; Codispoti, G; Cuffiani, M; D'Antone, I; Dallavalle, G M; Fabbri, F; Fanfani, A; Fasanella, D; Giacomelli, P; Giordano, V; Giunta, M; Grandi, C; Guerzoni, M; Marcellini, S; Masetti, G; Montanari, A; Navarria, F L; Odorici, F; Pellegrini, G; Perrotta, A; Rossi, A M; Rovelli, T; Siroli, G; Torromeo, G; Travaglini, R; Albergo, S; Costa, S; Potenza, R; Tricomi, A; Tuve, C; Barbagli, G; Broccolo, G; Ciulli, V; Civinini, C; D'Alessandro, R; Focardi, E; Frosali, S; Gallo, E; Genta, C; Landi, G; Lenzi, P; Meschini, M; Paoletti, S; Sguazzoni, G; Tropiano, A; Benussi, L; Bertani, M; Bianco, S; Colafranceschi, S; Colonna, D; Fabbri, F; Giardoni, M; Passamonti, L; Piccolo, D; Pierluigi, D; Ponzio, B; Russo, A; Fabbricatore, P; Musenich, R; Benaglia, A; Calloni, M; Cerati, G B; D'Angelo, P; De Guio, F; Farina, F M; Ghezzi, A; Govoni, P; Malberti, M; Malvezzi, S; Martelli, A; Menasce, D; Miccio, V; Moroni, L; Negri, P; Paganoni, M; Pedrini, D; Pullia, A; Ragazzi, S; Redaelli, N; Sala, S; Salerno, R; Tabarelli de Fatis, T; Tancini, V; Taroni, S; Buontempo, S; Cavallo, N; Cimmino, A; De Gruttola, M; Fabozzi, F; Iorio, A O M; Lista, L; Lomidze, D; Noli, P; Paolucci, P; Sciacca, C; Azzi, P; Bacchetta, N; Barcellan, L; Bellan, P; Bellato, M; Benettoni, M; Biasotto, M; Bisello, D; Borsato, E; Branca, A; Carlin, R; Castellani, L; Checchia, P; Conti, E; Dal Corso, F; De Mattia, M; Dorigo, T; Dosselli, U; Fanzago, F; Gasparini, F; Gasparini, U; Giubilato, P; Gonella, F; Gresele, A; Gulmini, M; Kaminskiy, A; Lacaprara, S; Lazzizzera, I; Margoni, M; Maron, G; Mattiazzo, S; Mazzucato, M; Meneghelli, M; Meneguzzo, A T; Michelotto, M; Montecassiano, F; Nespolo, M; Passaseo, M; Pegoraro, M; Perrozzi, L; Pozzobon, N; Ronchese, P; Simonetto, F; Toniolo, N; Torassa, E; Tosi, M; Triossi, A; Vanini, S; Ventura, S; Zotto, P; Zumerle, G; Baesso, P; Berzano, U; Bricola, S; Necchi, M M; Pagano, D; Ratti, S P; Riccardi, C; Torre, P; Vicini, A; Vitulo, P; Viviani, C; Aisa, D; Aisa, S; Babucci, E; Biasini, M; Bilei, G M; Caponeri, B; Checcucci, B; Dinu, N; Fanò, L; Farnesini, L; Lariccia, P; Lucaroni, A; Mantovani, G; Nappi, A; Piluso, A; Postolache, V; Santocchia, A; Servoli, L; Tonoiu, D; Vedaee, A; Volpe, R; Azzurri, P; Bagliesi, G; Bernardini, J; Berretta, L; Boccali, T; Bocci, A; Borrello, L; Bosi, F; Calzolari, F; Castaldi, R; Dell'Orso, R; Fiori, F; Foà, L; Gennai, S; Giassi, A; Kraan, A; Ligabue, F; Lomtadze, T; Mariani, F; Martini, L; Massa, M; Messineo, A; Moggi, A; Palla, F; Palmonari, F; Petragnani, G; Petrucciani, G; Raffaelli, F; Sarkar, S; Segneri, G; Serban, A T; Spagnolo, P; Tenchini, R; Tolaini, S; Tonelli, G; Venturi, A; Verdini, P G; Baccaro, S; Barone, L; Bartoloni, A; Cavallari, F; Dafinei, I; Del Re, D; Di Marco, E; Diemoz, M; Franci, D; Longo, E; Organtini, G; Palma, A; Pandolfi, F; Paramatti, R; Pellegrino, F; Rahatlou, S; Rovelli, C; Alampi, G; Amapane, N; Arcidiacono, R; Argiro, S; Arneodo, M; Biino, C; Borgia, M A; Botta, C; Cartiglia, N; Castello, R; Cerminara, G; Costa, M; Dattola, D; Dellacasa, G; Demaria, N; Dughera, G; Dumitrache, F; Graziano, A; Mariotti, C; Marone, M; Maselli, S; Migliore, E; Mila, G; Monaco, V; Musich, M; Nervo, M; Obertino, M M; Oggero, S; Panero, R; Pastrone, N; Pelliccioni, M; Romero, A; Ruspa, M; Sacchi, R; Solano, A; Staiano, A; Trapani, P P; Trocino, D; Vilela Pereira, A; Visca, L; Zampieri, A; Ambroglini, F; Belforte, S; Cossutti, F; Della Ricca, G; Gobbo, B; Penzo, A; Chang, S; Chung, J; Kim, D H; Kim, G N; Kong, D J; Park, H; Son, D C; Bahk, S Y; Song, S; Jung, S Y; Hong, B; Kim, H; Kim, J H; Lee, K S; Moon, D H; Park, S K; Rhee, H B; Sim, K S; Kim, J; Choi, M; Hahn, G; Park, I C; Choi, S; Choi, Y; Goh, J; Jeong, H; Kim, T J; Lee, J; Lee, S; Janulis, M; Martisiute, D; Petrov, P; Sabonis, T; Castilla Valdez, H; Sánchez Hernández, A; Carrillo Moreno, S; Morelos Pineda, A; Allfrey, P; Gray, R N C; Krofcheck, D; Bernardino Rodrigues, N; Butler, P H; Signal, T; Williams, J C; Ahmad, M; Ahmed, I; Ahmed, W; Asghar, M I; Awan, M I M; Hoorani, H R; Hussain, I; Khan, W A; Khurshid, T; Muhammad, S; Qazi, S; Shahzad, H; Cwiok, M; Dabrowski, R; Dominik, W; Doroba, K; Konecki, M; Krolikowski, J; Pozniak, K; Romaniuk, Ryszard; Zabolotny, W; Zych, P; Frueboes, T; Gokieli, R; Goscilo, L; Górski, M; Kazana, M; Nawrocki, K; Szleper, M; Wrochna, G; Zalewski, P; Almeida, N; Antunes Pedro, L; Bargassa, P; David, A; Faccioli, P; Ferreira Parracho, P G; Freitas Ferreira, M; Gallinaro, M; Guerra Jordao, M; Martins, P; Mini, G; Musella, P; Pela, J; Raposo, L; Ribeiro, P Q; Sampaio, S; Seixas, J; Silva, J; Silva, P; Soares, D; Sousa, M; Varela, J; Wöhri, H K; Altsybeev, I; Belotelov, I; Bunin, P; Ershov, Y; Filozova, I; Finger, M; Finger, M., Jr.; Golunov, A; Golutvin, I; Gorbounov, N; Kalagin, V; Kamenev, A; Karjavin, V; Konoplyanikov, V; Korenkov, V; Kozlov, G; Kurenkov, A; Lanev, A; Makankin, A; Mitsyn, V V; Moisenz, P; Nikonov, E; Oleynik, D; Palichik, V; Perelygin, V; Petrosyan, A; Semenov, R; Shmatov, S; Smirnov, V; Smolin, D; Tikhonenko, E; Vasil'ev, S; Vishnevskiy, A; Volodko, A; Zarubin, A; Zhiltsov, V; Bondar, N; Chtchipounov, L; Denisov, A; Gavrikov, Y; Gavrilov, G; Golovtsov, V; Ivanov, Y; Kim, V; Kozlov, V; Levchenko, P; Obrant, G; Orishchin, E; Petrunin, A; Shcheglov, Y; Shchetkovskiy, A; Sknar, V; Smirnov, I; Sulimov, V; Tarakanov, V; Uvarov, L; Vavilov, S; Velichko, G; Volkov, S; Vorobyev, A; Andreev, Yu; Anisimov, A; Antipov, P; Dermenev, A; Gninenko, S; Golubev, N; Kirsanov, M; Krasnikov, N; Matveev, V; Pashenkov, A; Postoev, V E; Solovey, A; Toropin, A; Troitsky, S; Baud, A; Epshteyn, V; Gavrilov, V; Ilina, N; Kaftanov, V; Kolosov, V; Kossov, M; Krokhotin, A; Kuleshov, S; Oulianov, A; Safronov, G; Semenov, S; Shreyber, I; Stolin, V; Vlasov, E; Zhokin, A; Boos, E; Dubinin, M; Dudko, L; Ershov, A; Gribushin, A; Klyukhin, V; Kodolova, O; Lokhtin, I; Petrushanko, S; Sarycheva, L; Savrin, V; Snigirev, A; Vardanyan, I; Dremin, I; Kirakosyan, M; Konovalova, N; Rusakov, S V; Vinogradov, A; Akimenko, S; Artamonov, A; Azhgirey, I; Bitioukov, S; Burtovoy, V; Grishin, V; Kachanov, V; Konstantinov, D; Krychkine, V; Levine, A; Lobov, I; Lukanin, V; Mel'nik, Y; Petrov, V; Ryutin, R; Slabospitsky, S; Sobol, A; Sytine, A; Tourtchanovitch, L; Troshin, S; Tyurin, N; Uzunian, A; Volkov, A; Adzic, P; Djordjevic, M; Jovanovic, D; Krpic, D; Maletic, D; Puzovic, J; Smiljkovic, N; Aguilar-Benitez, M; Alberdi, J; Alcaraz Maestre, J; Arce, P; Barcala, J M; Battilana, C; Burgos Lazaro, C; Caballero Bejar, J; Calvo, E; Cardenas Montes, M; Cepeda, M; Cerrada, M; Chamizo Llatas, M; Clemente, F; Colino, N; Daniel, M; De La Cruz, B; Delgado Peris, A; Diez Pardos, C; Fernandez Bedoya, C; Fernández Ramos, J P; Ferrando, A; Flix, J; Fouz, M C; Garcia-Abia, P; Garcia-Bonilla, A C; Gonzalez Lopez, O; Goy Lopez, S; Hernandez, J M; Josa, M I; Marin, J; Merino, G; Molina, J; Molinero, A; Navarrete, J J; Oller, J C; Puerta Pelayo, J; Romero, L; Santaolalla, J; Villanueva Munoz, C; Willmott, C; Yuste, C; Albajar, C; Blanco Otano, M; de Trocóniz, J F; Garcia Raboso, A; Lopez Berengueres, J O; Cuevas, J; Fernandez Menendez, J; Gonzalez Caballero, I; Lloret Iglesias, L; Naves Sordo, H; Vizan Garcia, J M; Cabrillo, I J; Calderon, A; Chuang, S H; Diaz Merino, I; Diez Gonzalez, C; Duarte Campderros, J; Fernandez, M; Gomez, G; Gonzalez Sanchez, J; Gonzalez Suarez, R; Jorda, C; Lobelle Pardo, P; Lopez Virto, A; Marco, J; Marco, R; Martinez Rivero, C; Martinez Ruiz del Arbol, P; Matorras, F; Rodrigo, T; Ruiz Jimeno, A; Scodellaro, L; Sobron Sanudo, M; Vila, I; Vilar Cortabitarte, R; Abbaneo, D; Albert, E; Alidra, M; Ashby, S; Auffray, E; Baechler, J; Baillon, P; Ball, A H; Bally, S L; Barney, D; Beaudette, F; Bellan, R; Benedetti, D; Benelli, G; Bernet, C; Bloch, P; Bolognesi, S; Bona, M; Bos, J; Bourgeois, N; Bourrel, T; Breuker, H; Bunkowski, K; Campi, D; Camporesi, T; Cano, E; Cattai, A; Chatelain, J P; Chauvey, M; Christiansen, T; Coarasa Perez, J A; Conde Garcia, A; Covarelli, R; Curé, B; De Roeck, A; Delachenal, V; Deyrail, D; Di Vincenzo, S; Dos Santos, S; Dupont, T; Edera, L M; Elliott-Peisert, A; Eppard, M; Favre, M; Frank, N; Funk, W; Gaddi, A; Gastal, M; Gateau, M; Gerwig, H; Gigi, D; Gill, K; Giordano, D; Girod, J P; Glege, F; Gomez-Reino Garrido, R; Goudard, R; Gowdy, S; Guida, R; Guiducci, L; Gutleber, J; Hansen, M; Hartl, C; Harvey, J; Hegner, B; Hoffmann, H F; Holzner, A; Honma, A; Huhtinen, M; Innocente, V; Janot, P; Le Godec, G; Lecoq, P; Leonidopoulos, C; Loos, R; Lourenço, C; Lyonnet, A; Macpherson, A; Magini, N; Maillefaud, J D; Maire, G; Mäki, T; Malgeri, L; Mannelli, M; Masetti, L; Meijers, F; Meridiani, P; Mersi, S; Meschi, E; Meynet Cordonnier, A; Moser, R; Mulders, M; Mulon, J; Noy, M; Oh, A; Olesen, G; Onnela, A; Orimoto, T; Orsini, L; Perez, E; Perinic, G; Pernot, J F; Petagna, P; Petiot, P; Petrilli, A; Pfeiffer, A; Pierini, M; Pimiä, M; Pintus, R; Pirollet, B; Postema, H; Racz, A; Ravat, S; Rew, S B; Rodrigues Antunes, J; Rolandi, G; Rovere, M; Ryjov, V; Sakulin, H; Samyn, D; Sauce, H; Schäfer, C; Schlatter, W D; Schröder, M; Schwick, C; Sciaba, A; Segoni, I; Sharma, A; Siegrist, N; Siegrist, P; Sinanis, N; Sobrier, T; Sphicas, P; Spiga, D; Spiropulu, M; Stöckli, F; Traczyk, P; Tropea, P; Troska, J; Tsirou, A; Veillet, L; Veres, G I; Voutilainen, M; Wertelaers, P; Zanetti, M; Bertl, W; Deiters, K; Erdmann, W; Gabathuler, K; Horisberger, R; Ingram, Q; Kaestli, H C; König, S; Kotlinski, D; Langenegger, U; Meier, F; Renker, D; Rohe, T; Sibille, J; Starodumov, A; Betev, B; Caminada, L; Chen, Z; Cittolin, S; Da Silva Di Calafiori, D R; Dambach, S; Dissertori, G; Dittmar, M; Eggel, C; Eugster, J; Faber, G; Freudenreich, K; Grab, C; Hervé, A; Hintz, W; Lecomte, P; Luckey, P D; Lustermann, W; Marchica, C; Milenovic, P; Moortgat, F; Nardulli, A; Nessi-Tedaldi, F; Pape, L; Pauss, F; Punz, T; Rizzi, A; Ronga, F J; Sala, L; Sanchez, A K; Sawley, M C; Sordini, V; Stieger, B; Tauscher, L; Thea, A; Theofilatos, K; Treille, D; Trüb, P; Weber, M; Wehrli, L; Weng, J; Zelepoukine, S; Amsler, C; Chiochia, V; De Visscher, S; Regenfus, C; Robmann, P; Rommerskirchen, T; Schmidt, A; Tsirigkas, D; Wilke, L; Chang, Y H; Chen, E A; Chen, W T; Go, A; Kuo, C M; Li, S W; Lin, W; Bartalini, P; Chang, P; Chao, Y; Chen, K F; Hou, W S; Hsiung, Y; Lei, Y J; Lin, S W; Lu, R S; Schümann, J; Shiu, J G; Tzeng, Y M; Ueno, K; Velikzhanin, Y; Wang, C C; Wang, M; Adiguzel, A; Ayhan, A; Azman Gokce, A; Bakirci, M N; Cerci, S; Dumanoglu, I; Eskut, E; Girgis, S; Gurpinar, E; Hos, I; Karaman, T; Kayis Topaksu, A; Kurt, P; Önengüt, G; Önengüt Gökbulut, G; Ozdemir, K; Ozturk, S; Polatöz, A; Sogut, K; Tali, B; Topakli, H; Uzun, D; Vergili, L N; Vergili, M; Akin, I V; Aliev, T; Bilmis, S; Deniz, M; Gamsizkan, H; Guler, A M; Öcalan, K; Serin, M; Sever, R; Surat, U E; Zeyrek, M; Deliomeroglu, M; Demir, D; Gülmez, E; Halu, A; Isildak, B; Kaya, M; Kaya, O; Ozkorucuklu, S; Sonmez, N; Levchuk, L; Lukyanenko, S; Soroka, D; Zub, S; Bostock, F; Brooke, J J; Cheng, T L; Cussans, D; Frazier, R; Goldstein, J; Grant, N; Hansen, M; Heath, G P; Heath, H F; Hill, C; Huckvale, B; Jackson, J; Mackay, C K; Metson, S; Newbold, D M; Nirunpong, K; Smith, V J; Velthuis, J; Walton, R; Bell, K W; Brew, C; Brown, R M; Camanzi, B; Cockerill, D J A; Coughlan, J A; Geddes, N I; Harder, K; Harper, S; Kennedy, B W; Murray, P; Shepherd-Themistocleous, C H; Tomalin, I R; Williams, J H; Womersley, W J; Worm, S D; Bainbridge, R; Ball, G; Ballin, J; Beuselinck, R; Buchmuller, O; Colling, D; Cripps, N; Davies, G; Della Negra, M; Foudas, C; Fulcher, J; Futyan, D; Hall, G; Hays, J; Iles, G; Karapostoli, G; MacEvoy, B C; Magnan, A M; Marrouche, J; Nash, J; Nikitenko, A; Papageorgiou, A; Pesaresi, M; Petridis, K; Pioppi, M; Raymond, D M; Rompotis, N; Rose, A; Ryan, M J; Seez, C; Sharp, P; Sidiropoulos, G; Stettler, M; Stoye, M; Takahashi, M; Tapper, A; Timlin, C; Tourneur, S; Vazquez Acosta, M; Virdee, T; Wakefield, S; Wardrope, D; Whyntie, T; Wingham, M; Cole, J E; Goitom, I; Hobson, P R; Khan, A; Kyberd, P; Leslie, D; Munro, C; Reid, I D; Siamitros, C; Taylor, R; Teodorescu, L; Yaselli, I; Bose, T; Carleton, M; Hazen, E; Heering, A H; Heister, A; John, J St; Lawson, P; Lazic, D; Osborne, D; Rohlf, J; Sulak, L; Wu, S; Andrea, J; Avetisyan, A; Bhattacharya, S; Chou, J P; Cutts, D; Esen, S; Kukartsev, G; Landsberg, G; Narain, M; Nguyen, D; Speer, T; Tsang, K V; Breedon, R; Calderon De La Barca Sanchez, M; Case, M; Cebra, D; Chertok, M; Conway, J; Cox, P T; Dolen, J; Erbacher, R; Friis, E; Ko, W; Kopecky, A; Lander, R; Lister, A; Liu, H; Maruyama, S; Miceli, T; Nikolic, M; Pellett, D; Robles, J; Searle, M; Smith, J; Squires, M; Stilley, J; Tripathi, M; Vasquez Sierra, R; Veelken, C; Andreev, V; Arisaka, K; Cline, D; Cousins, R; Erhan, S; Hauser, J; Ignatenko, M; Jarvis, C; Mumford, J; Plager, C; Rakness, G; Schlein, P; Tucker, J; Valuev, V; Wallny, R; Yang, X; Babb, J; Bose, M; Chandra, A; Clare, R; Ellison, J A; Gary, J W; Hanson, G; Jeng, G Y; Kao, S C; Liu, F; Liu, H; Luthra, A; Nguyen, H; Pasztor, G; Satpathy, A; Shen, B C; Stringer, R; Sturdy, J; Sytnik, V; Wilken, R; Wimpenny, S; Branson, J G; Dusinberre, E; Evans, D; Golf, F; Kelley, R; Lebourgeois, M; Letts, J; Lipeles, E; Mangano, B; Muelmenstaedt, J; Norman, M; Padhi, S; Petrucci, A; Pi, H; Pieri, M; Ranieri, R; Sani, M; Sharma, V; Simon, S; Würthwein, F; Yagil, A; Campagnari, C; D'Alfonso, M; Danielson, T; Garberson, J; Incandela, J; Justus, C; Kalavase, P; Koay, S A; Kovalskyi, D; Krutelyov, V; Lamb, J; Lowette, S; Pavlunin, V; Rebassoo, F; Ribnik, J; Richman, J; Rossin, R; Stuart, D; To, W; Vlimant, J R; Witherell, M; Apresyan, A; Bornheim, A; Bunn, J; Chiorboli, M; Gataullin, M; Kcira, D; Litvine, V; Ma, Y; Newman, H B; Rogan, C; Timciuc, V; Veverka, J; Wilkinson, R; Yang, Y; Zhang, L; Zhu, K; Zhu, R Y; Akgun, B; Carroll, R; Ferguson, T; Jang, D W; Jun, S Y; Paulini, M; Russ, J; Terentyev, N; Vogel, H; Vorobiev, I; Cumalat, J P; Dinardo, M E; Drell, B R; Ford, W T; Heyburn, B; Luiggi Lopez, E; Nauenberg, U; Stenson, K; Ulmer, K; Wagner, S R; Zang, S L; Agostino, L; Alexander, J; Blekman, F; Cassel, D; Chatterjee, A; Das, S; Gibbons, L K; Heltsley, B; Hopkins, W; Khukhunaishvili, A; Kreis, B; Kuznetsov, V; Patterson, J R; Puigh, D; Ryd, A; Shi, X; Stroiney, S; Sun, W; Teo, W D; Thom, J; Vaughan, J; Weng, Y; Wittich, P; Beetz, C P; Cirino, G; Sanzeni, C; Winn, D; Abdullin, S; Afaq, M A; Albrow, M; Ananthan, B; Apollinari, G; Atac, M; Badgett, W; Bagby, L; Bakken, J A; Baldin, B; Banerjee, S; Banicz, K; Bauerdick, L A T; Beretvas, A; Berryhill, J; Bhat, P C; Biery, K; Binkley, M; Bloch, I; Borcherding, F; Brett, A M; Burkett, K; Butler, J N; Chetluru, V; Cheung, H W K; Chlebana, F; Churin, I; Cihangir, S; Crawford, M; Dagenhart, W; Demarteau, M; Derylo, G; Dykstra, D; Eartly, D P; Elias, J E; Elvira, V D; Evans, D; Feng, L; Fischler, M; Fisk, I; Foulkes, S; Freeman, J; Gartung, P; Gottschalk, E; Grassi, T; Green, D; Guo, Y; Gutsche, O; Hahn, A; Hanlon, J; Harris, R M; Holzman, B; Howell, J; Hufnagel, D; James, E; Jensen, H; Johnson, M; Jones, C D; Joshi, U; Juska, E; Kaiser, J; Klima, B; Kossiakov, S; Kousouris, K; Kwan, S; Lei, C M; Limon, P; Lopez Perez, J A; Los, S; Lueking, L; Lukhanin, G; Lusin, S; Lykken, J; Maeshima, K; Marraffino, J M; Mason, D; McBride, P; Miao, T; Mishra, K; Moccia, S; Mommsen, R; Mrenna, S; Muhammad, A S; Newman-Holmes, C; Noeding, C; O'Dell, V; Prokofyev, O; Rivera, R; Rivetta, C H; Ronzhin, A; Rossman, P; Ryu, S; Sekhri, V; Sexton-Kennedy, E; Sfiligoi, I; Sharma, S; Shaw, T M; Shpakov, D; Skup, E; Smith, R P; Soha, A; Spalding, W J; Spiegel, L; Suzuki, I; Tan, P; Tanenbaum, W; Tkaczyk, S; Trentadue, R; Uplegger, L; Vaandering, E W; Vidal, R; Whitmore, J; Wicklund, E; Wu, W; Yarba, J; Yumiceva, F; Yun, J C; Acosta, D; Avery, P; Barashko, V; Bourilkov, D; Chen, M; Di Giovanni, G P; Dobur, D; Drozdetskiy, A; Field, R D; Fu, Y; Furic, I K; Gartner, J; Holmes, D; Kim, B; Klimenko, S; Konigsberg, J; Korytov, A; Kotov, K; Kropivnitskaya, A; Kypreos, T; Madorsky, A; Matchev, K; Mitselmakher, G; Pakhotin, Y; Piedra Gomez, J; Prescott, C; Rapsevicius, V; Remington, R; Schmitt, M; Scurlock, B; Wang, D; Yelton, J; Ceron, C; Gaultney, V; Kramer, L; Lebolo, L M; Linn, S; Markowitz, P; Martinez, G; Rodriguez, J L; Adams, T; Askew, A; Baer, H; Bertoldi, M; Chen, J; Dharmaratna, W G D; Gleyzer, S V; Haas, J; Hagopian, S; Hagopian, V; Jenkins, M; Johnson, K F; Prettner, E; Prosper, H; Sekmen, S; Baarmand, M M; Guragain, S; Hohlmann, M; Kalakhety, H; Mermerkaya, H; Ralich, R; Vodopiyanov, I; Abelev, B; Adams, M R; Anghel, I M; Apanasevich, L; Bazterra, V E; Betts, R R; Callner, J; Castro, M A; Cavanaugh, R; Dragoiu, C; Garcia-Solis, E J; Gerber, C E; Hofman, D J; Khalatian, S; Mironov, C; Shabalina, E; Smoron, A; Varelas, N; Akgun, U; Albayrak, E A; Ayan, A S; Bilki, B; Briggs, R; Cankocak, K; Chung, K; Clarida, W; Debbins, P; Duru, F; Ingram, F D; Lae, C K; McCliment, E; Merlo, J P; Mestvirishvili, A; Miller, M J; Moeller, A; Nachtman, J; Newsom, C R; Norbeck, E; Olson, J; Onel, Y; Ozok, F; Parsons, J; Schmidt, I; Sen, S; Wetzel, J; Yetkin, T; Yi, K; Barnett, B A; Blumenfeld, B; Bonato, A; Chien, C Y; Fehling, D; Giurgiu, G; Gritsan, A V; Guo, Z J; Maksimovic, P; Rappoccio, S; Swartz, M; Tran, N V; Zhang, Y; Baringer, P; Bean, A; Grachov, O; Murray, M; Radicci, V; Sanders, S; Wood, J S; Zhukova, V; Bandurin, D; Bolton, T; Kaadze, K; Liu, A; Maravin, Y; Onoprienko, D; Svintradze, I; Wan, Z; Gronberg, J; Hollar, J; Lange, D; Wright, D; Baden, D; Bard, R; Boutemeur, M; Eno, S C; Ferencek, D; Hadley, N J; Kellogg, R G; Kirn, M; Kunori, S; Rossato, K; Rumerio, P; Santanastasio, F; Skuja, A; Temple, J; Tonjes, M B; Tonwar, S C; Toole, T; Twedt, E; Alver, B; Bauer, G; Bendavid, J; Busza, W; Butz, E; Cali, I A; Chan, M; D'Enterria, D; Everaerts, P; Gomez Ceballos, G; Hahn, K A; Harris, P; Jaditz, S; Kim, Y; Klute, M; Lee, Y J; Li, W; Loizides, C; Ma, T; Miller, M; Nahn, S; Paus, C; Roland, C; Roland, G; Rudolph, M; Stephans, G; Sumorok, K; Sung, K; Vaurynovich, S; Wenger, E A; Wyslouch, B; Xie, S; Yilmaz, Y; Yoon, A S; Bailleux, D; Cooper, S I; Cushman, P; Dahmes, B; De Benedetti, A; Dolgopolov, A; Dudero, P R; Egeland, R; Franzoni, G; Haupt, J; Inyakin, A; Klapoetke, K; Kubota, Y; Mans, J; Mirman, N; Petyt, D; Rekovic, V; Rusack, R; Schroeder, M; Singovsky, A; Zhang, J; Cremaldi, L M; Godang, R; Kroeger, R; Perera, L; Rahmat, R; Sanders, D A; Sonnek, P; Summers, D; Bloom, K; Bockelman, B; Bose, S; Butt, J; Claes, D R; Dominguez, A; Eads, M; Keller, J; Kelly, T; Kravchenko, I; Lazo-Flores, J; Lundstedt, C; Malbouisson, H; Malik, S; Snow, G R; Baur, U; Iashvili, I; Kharchilava, A; Kumar, A; Smith, K; Strang, M; Alverson, G; Barberis, E; Boeriu, O; Eulisse, G; Govi, G; McCauley, T; Musienko, Y; Muzaffar, S; Osborne, I; Paul, T; Reucroft, S; Swain, J; Taylor, L; Tuura, L; Anastassov, A; Gobbi, B; Kubik, A; Ofierzynski, R A; Pozdnyakov, A; Schmitt, M; Stoynev, S; Velasco, M; Won, S; Antonelli, L; Berry, D; Hildreth, M; Jessop, C; Karmgard, D J; Kolberg, T; Lannon, K; Lynch, S; Marinelli, N; Morse, D M; Ruchti, R; Slaunwhite, J; Warchol, J; Wayne, M; Bylsma, B; Durkin, L S; Gilmore, J; Gu, J; Killewald, P; Ling, T Y; Williams, G; Adam, N; Berry, E; Elmer, P; Garmash, A; Gerbaudo, D; Halyo, V; Hunt, A; Jones, J; Laird, E; Marlow, D; Medvedeva, T; Mooney, M; Olsen, J; Piroué, P; Stickland, D; Tully, C; Werner, J S; Wildish, T; Xie, Z; Zuranski, A; Acosta, J G; Bonnett Del Alamo, M; Huang, X T; Lopez, A; Mendez, H; Oliveros, S; Ramirez Vargas, J E; Santacruz, N; Zatzerklyany, A; Alagoz, E; Antillon, E; Barnes, V E; Bolla, G; Bortoletto, D; Everett, A; Garfinkel, A F; Gecse, Z; Gutay, L; Ippolito, N; Jones, M; Koybasi, O; Laasanen, A T; Leonardo, N; Liu, C; Maroussov, V; Merkel, P; Miller, D H; Neumeister, N; Sedov, A; Shipsey, I; Yoo, H D; Zheng, Y; Jindal, P; Parashar, N; Cuplov, V; Ecklund, K M; Geurts, F J M; Liu, J H; Maronde, D; Matveev, M; Padley, B P; Redjimi, R; Roberts, J; Sabbatini, L; Tumanov, A; Betchart, B; Bodek, A; Budd, H; Chung, Y S; de Barbaro, P; Demina, R; Flacher, H; Gotra, Y; Harel, A; Korjenevski, S; Miner, D C; Orbaker, D; Petrillo, G; Vishnevskiy, D; Zielinski, M; Bhatti, A; Demortier, L; Goulianos, K; Hatakeyama, K; Lungu, G; Mesropian, C; Yan, M; Atramentov, O; Bartz, E; Gershtein, Y; Halkiadakis, E; Hits, D; Lath, A; Rose, K; Schnetzer, S; Somalwar, S; Stone, R; Thomas, S; Watts, T L; Cerizza, G; Hollingsworth, M; Spanier, S; Yang, Z C; York, A; Asaadi, J; Aurisano, A; Eusebi, R; Golyash, A; Gurrola, A; Kamon, T; Nguyen, C N; Pivarski, J; Safonov, A; Sengupta, S; Toback, D; Weinberger, M; Akchurin, N; Berntzon, L; Gumus, K; Jeong, C; Kim, H; Lee, S W; Popescu, S; Roh, Y; Sill, A; Volobouev, I; Washington, E; Wigmans, R; Yazgan, E; Engh, D; Florez, C; Johns, W; Pathak, S; Sheldon, P; Andelin, D; Arenton, M W; Balazs, M; Boutle, S; Buehler, M; Conetti, S; Cox, B; Hirosky, R; Ledovskoy, A; Neu, C; Phillips II, D; Ronquest, M; Yohay, R; Gollapinni, S; Gunthoti, K; Harr, R; Karchin, P E; Mattson, M; Sakharov, A; Anderson, M; Bachtis, M; Bellinger, J N; Carlsmith, D; Crotty, I; Dasu, S; Dutta, S; Efron, J; Feyzi, F; Flood, K; Gray, L; Grogg, K S; Grothe, M; Hall-Wilton, R; Jaworski, M; Klabbers, P; Klukas, J; Lanaro, A; Lazaridis, C; Leonard, J; Loveless, R; Magrans de Abril, M; Mohapatra, A; Ott, G; Polese, G; Reeder, D; Savin, A; Smith, W H; Sourkov, A; Swanson, J; Weinberg, M; Wenman, D; Wensveen, M; White, A

    2010-01-01

    In October and November 2008, the CMS collaboration conducted a programme of cosmic ray data taking, which has recorded about 270 million events. The Resistive Plate Chamber system, which is part of the CMS muon detection system, was successfully operated in the full barrel. More than 98% of the channels were operational during the exercise with typical detection efficiency of 90%. In this paper, the performance of the detector during these dedicated runs is reported.

  3. Three-Dimensional, Numerical Investigation of Flow and Heat Transfer in Rectangular Channels Subject to Partial Blockage

    KAUST Repository

    Salama, Amgad; El-Amin, Mohamed; Sun, Shuyu

    2014-01-01

    Numerical simulation of flow and heat transfer in two adjacent channels is conducted with one of the channels partially blocked. This system simulates typical channels of a material testing reactor. The blockage is assumed due to the buckling of one of the channel plates inward along its width. The blockage ratio considered in this work is defined as the ratio between the cross-sectional area of the blocked and the unblocked channel. In this work, we consider a blockage ratio of approximately 40%. However, the blockage is different along the width of the channel, ranging from 0% at the end of the channel to 90% in the middle. The channel walls are sandwiching volumetric heat sources that vary spatially as chopped cosine functions. Interesting patterns are highlighted and investigated. The reduction in the flow area of one channel results in the flow redistributing among the two channels according to the changes in their hydraulic conductivities. The results of the numerical simulations show that the maximum wall temperature in the blocked channel is well below the boiling temperature at the operating pressure.

  4. Three-Dimensional, Numerical Investigation of Flow and Heat Transfer in Rectangular Channels Subject to Partial Blockage

    KAUST Repository

    Salama, Amgad

    2014-08-25

    Numerical simulation of flow and heat transfer in two adjacent channels is conducted with one of the channels partially blocked. This system simulates typical channels of a material testing reactor. The blockage is assumed due to the buckling of one of the channel plates inward along its width. The blockage ratio considered in this work is defined as the ratio between the cross-sectional area of the blocked and the unblocked channel. In this work, we consider a blockage ratio of approximately 40%. However, the blockage is different along the width of the channel, ranging from 0% at the end of the channel to 90% in the middle. The channel walls are sandwiching volumetric heat sources that vary spatially as chopped cosine functions. Interesting patterns are highlighted and investigated. The reduction in the flow area of one channel results in the flow redistributing among the two channels according to the changes in their hydraulic conductivities. The results of the numerical simulations show that the maximum wall temperature in the blocked channel is well below the boiling temperature at the operating pressure.

  5. Numerical Study of the Inertia Effect on Flow Distribution in Micro-gap Plate Heat Exchanger

    International Nuclear Information System (INIS)

    Park, Jang Min; Yoon, Seok Ho; Lee, Kong Hoon; Song Chan Ho

    2014-01-01

    This paper presents numerical study on flow and heat transfer characteristics in micro-gap plate heat exchanger. In particular, we investigate the effect of flow inertia on the flow distribution from single main channel to multiple parallel micro-gaps. The flow regime of the main channel is varied from laminar regime (Reynolds number of 100) to turbulent regime (Reynolds number of 10000) by changing the flow rate, and non-uniformity of the flow distribution and temperature field is evaluated quantitatively based on the standard deviation. The flow distribution is found to be significantly affected by not only the header design but also the flow rate of the main channel. It is also observed that the non-uniformity of the temperature field has its maximum at the intermediate flow regime

  6. Resistive Plate Chambers for Imaging Calorimetry - the DHCAL

    CERN Document Server

    Repond, Jose

    2014-01-01

    The DHCAL, the Digital Hadron Calorimeter, is a prototype calorimeter based on Resistive Plate Chambers (RPCs). The design emphasizes the imaging capabilities of the detector in an effort to optimize the calorimeter for the application of Particle Flow Algorithms (PFAs) to the reconstruction of hadronic jet energies in a colliding beam environment. The readout of the chambers is segmented into 1 x 1 cm2 pads, each read out with a 1-bit (single threshold) resolution. The prototype with approximately 500,000 readout channels underwent extensive testing in both the Fermilab and CERN test beams. This talk presents preliminary findings from the analysis of data collected at the test beams.

  7. Locking screw-plate interface stability in carbon-fibre reinforced polyetheretherketone proximal humerus plates.

    Science.gov (United States)

    Hak, David J; Fader, Ryan; Baldini, Todd; Chadayammuri, Vivek B S

    2017-09-01

    Carbon-fibre reinforced polyetheretherketone (CFR-PEEK) plates have recently been introduced for proximal humerus fracture treatment. The purpose of this study was to compare the locking screw-plate interface stability in CFR-PEEK versus stainless steel (SS) proximal humerus plates. Locking screw mechanical stability was evaluated independently in proximal and shaft plate holes. Stiffness and load to failure were tested for three conditions: (1) on-axis locking screw insertion in CFR-PEEK versus SS plates, (2) on-axis locking screw insertion, removal, and reinsertion in CFR-PEEK plates, and (3) 10-degree off-axis locking screw insertion in CFR-PEEK plates. Cantilever bending at a rate of 1 mm/minute was produced by an Instron machine and load-displacement data recorded. Shaft locking screw load to failure was significantly greater in CFR-PEEK plates compared to SS plates (746.4 ± 89.7 N versus 596.5 ± 32.6 N, p PEEK plates (p PEEK plates. The mechanical stability of locking screws in CFR-PEEK plates is comparable or superior to locking screws in SS plates.

  8. Voltage-current characteristics of a pin-plate system with different plate configurations

    International Nuclear Information System (INIS)

    Feng, Zhuangbo; Long, Zhengwei

    2013-01-01

    In this paper, the voltage-current (V-I) characteristics of a pin-plate system with four types of collection plate configurations are studied experimentally. The collection plates consider a single metal plate, a metal plate with a fly ash cake layer, a metal plate with a clean filter media and a metal plate with a dirty filter media. The results show that the clean filter media has no obvious effect on the V-I characteristics. But the dirty filter media reduces the current density because of its high resistance. The thick fly ash cake layer increase current density because of the anti-corona effect but the increment is not very obvious.

  9. Mechanism of falling water limitation in two-phase counter flow through single hole vertical channel

    International Nuclear Information System (INIS)

    Sudo, Yukio; Ohnuki, Akira

    1983-01-01

    In the safety evaluation at the time of loss coolant accident, which is a credible accident in LWRs, recently main effort has been concentrated to the optimum evaluation calculation, and the grasp of vapor-liquid two-phase flow phenomena has become important. As one of the important phenomena, there is the limitation of falling water in two-phase counter flow through a vertical channel. This phenomenon is divided into the limitation of falling water stored in an upper plenum to a core through an upper core-supporting plate and a tie plate at the time of reflooding, and the limitation of falling emergency core-cooling water in downcomer channels at the time of reflooding in PWRs, under the presence of rising steam flow. In both cases, the evaluation of the quantity of falling water is important, because it contributes directly to core cooling. In this research, in order to clarify the mechanism of limitation of falling water in two-phase vertical counter flow, first, two-phase flow of air-water system through a single-hole vertical channel was taken up, and the effect of main parameters was experimentally studied. At the same time, the theoretical investigation was performed, and the comparison with the experimental results obtained so far was carried out. The different mechanisms for short and long channels gave the good results. (Kako, I.)

  10. An induced charge readout scheme incorporating image charge splitting on discrete pixels

    International Nuclear Information System (INIS)

    Kataria, D.O.; Lapington, J.S.

    2003-01-01

    Top hat electrostatic analysers used in space plasma instruments typically use microchannel plates (MCPs) followed by discrete pixel anode readout for the angular definition of the incoming particles. Better angular definition requires more pixels/readout electronics channels but with stringent mass and power budgets common in space applications, the number of channels is restricted. We describe here a technique that improves the angular definition using induced charge and an interleaved anode pattern. The technique adopts the readout philosophy used on the CRRES and CLUSTER I instruments but has the advantages of the induced charge scheme and significantly reduced capacitance. Charge from the MCP collected by an anode pixel is inductively split onto discrete pixels whose geometry can be tailored to suit the scientific requirements of the instrument. For our application, the charge is induced over two pixels. One of them is used for a coarse angular definition but is read out by a single channel of electronics, allowing a higher rate handling. The other provides a finer angular definition but is interleaved and hence carries the expense of lower rate handling. Using the technique and adding four channels of electronics, a four-fold increase in the angular resolution is obtained. Details of the scheme and performance results are presented

  11. Fluid Flow and Infrared Image Analyses on Endwall Fitted with Short Rectangular Plate Fin

    Institute of Scientific and Technical Information of China (English)

    Kenyu OYAKAWA; Islam Md. DIDARUL; Minoru YAGA

    2006-01-01

    An experimental investigation is carried out to study fluid flow and heat transfer characteristics on the endwall fitted with arrays ( 7 × 7 ) of short rectangular plate fins of different pattern (co-angular and zigzag) for different pitch ratio. Experiments were conducted in a rectangular duct of 50 mm height for an air flow of Reynolds number ranged from 18750 to 62500 based on the equivalent diameter and air velocity of the duct. Infrared image analysis technique was employed to make clear the characteristics of local heat transfer coefficients on fin base, endwall and overall surface. Flow pattern around the short rectangular plates were visualized by inducing fluorescent dye in a water channel and longitudinal vortices were observed. Increasing the distance between plates in flow direction causes heat transfer enhancement for co-angular pattern, while decreasing the distance causes heat transfer enhancement for zigzag pattern. Zigzag pattern with pitch ratio 2 is found to be more effective in heat transfer enhancement than any other cases investigated.

  12. Multi-dimensional diagnostics of high power ion beams by Arrayed Pinhole Camera System

    International Nuclear Information System (INIS)

    Yasuike, K.; Miyamoto, S.; Shirai, N.; Akiba, T.; Nakai, S.; Imasaki, K.; Yamanaka, C.

    1993-01-01

    The authors developed multi-dimensional beam diagnostics system (with spatially and time resolution). They used newly developed Arrayed Pinhole Camera (APC) for this diagnosis. The APC can get spatial distribution of divergence and flux density. They use two types of particle detectors in this study. The one is CR-39 can get time integrated images. The other one is gated Micro-Channel-Plate (MCP) with CCD camera. It enables time resolving diagnostics. The diagnostics systems have resolution better than 10mrad divergence, 0.5mm spatial resolution on the objects respectively. The time resolving system has 10ns time resolution. The experiments are performed on Reiden-IV and Reiden-SHVS induction linac. The authors get time integrated divergence distributions on Reiden-IV proton beam. They also get time resolved image on Reiden-SHVS

  13. Experimental study on heat transfer augmentation for high heat flux removal in rib-roughened narrow channels

    Energy Technology Data Exchange (ETDEWEB)

    Islam, M.S.; Monde, Masanori [Saga Univ. (Japan); Hino, Ryutaro; Haga, Katsuhiro; Sudo, Yukio

    1997-07-01

    Frictional pressure drop and heat transfer performance in a very narrow rectangular channel having one-sided constant heat flux and repeated-ribs for turbulent flow have been investigated experimentally, and their experimental correlations were obtained using the least square method. The rib pitch-to-height ratios(p/k) were 10 and 20 while holding the rib height constant at 0.2mm, the Reynolds number(Re) from 2,414 to 98,458 under different channel heights of 1.2mm, 2.97mm, and 3.24mm, the rib height-to-channel equivalent diameter(k/De) of 0.03, 0.04, and 0.09 respectively. The results show that the rib-roughened surface augments heat transfer 2-3 times higher than that of the smooth surface with the expense of 2.8-4 times higher frictional pressure drop under Re=5000-10{sup 5}, p/k=10, and H=1.2mm. Experimental results obtained by channel height, H=1.2mm shows a little bit higher heat transfer and friction factor performance than the higher channel height, H=3.24mm. The effect of fin and consequently higher turbulence intensity are responsible for producing higher heat transfer rates. The obtained correlations could be used to design the cooling passages between the target plates to remove high heat flux up to 12MW/m{sup 2} generated at target plates in a high-intensity proton accelerator system. (author). 54 refs.

  14. Experimental study on heat transfer augmentation for high heat flux removal in rib-roughened narrow channels

    International Nuclear Information System (INIS)

    Islam, M.S.; Monde, Masanori; Hino, Ryutaro; Haga, Katsuhiro; Sudo, Yukio.

    1997-07-01

    Frictional pressure drop and heat transfer performance in a very narrow rectangular channel having one-sided constant heat flux and repeated-ribs for turbulent flow have been investigated experimentally, and their experimental correlations were obtained using the least square method. The rib pitch-to-height ratios(p/k) were 10 and 20 while holding the rib height constant at 0.2mm, the Reynolds number(Re) from 2,414 to 98,458 under different channel heights of 1.2mm, 2.97mm, and 3.24mm, the rib height-to-channel equivalent diameter(k/De) of 0.03, 0.04, and 0.09 respectively. The results show that the rib-roughened surface augments heat transfer 2-3 times higher than that of the smooth surface with the expense of 2.8-4 times higher frictional pressure drop under Re=5000-10 5 , p/k=10, and H=1.2mm. Experimental results obtained by channel height, H=1.2mm shows a little bit higher heat transfer and friction factor performance than the higher channel height, H=3.24mm. The effect of fin and consequently higher turbulence intensity are responsible for producing higher heat transfer rates. The obtained correlations could be used to design the cooling passages between the target plates to remove high heat flux up to 12MW/m 2 generated at target plates in a high-intensity proton accelerator system. (author). 54 refs

  15. Computational Fluid Dynamic Pressure Drop Estimation of Flow between Parallel Plates

    Energy Technology Data Exchange (ETDEWEB)

    Son, Hyung Min; Yang, Soo Hyung; Park, Jong Hark [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    Many pool type reactors have forced downward flows inside the core during normal operation; there is a chance of flow inversion when transients occur. During this phase, the flow undergo transition between turbulent and laminar regions where drastic changes take place in terms of momentum and heat transfer, and the decrease in safety margin is usually observed. Additionally, for high Prandtl number fluids such as water, an effect of the velocity profile inside the channel on the temperature distribution is more pronounced over the low Prandtl number ones. This makes the checking of its pressure drop estimation accuracy less important, assuming the code verification is complete. With an advent of powerful computer hardware, engineering applications of computational fluid dynamics (CFD) methods have become quite common these days. Especially for a fully-turbulent and single phase convective heat transfer, the predictability of the commercial codes has matured enough so that many well-known companies adopt those to accelerate a product development cycle and to realize an increased profitability. In contrast to the above, the transition models for the CFD code are still under development, and the most of the models show limited generality and prediction accuracy. Unlike the system codes, the CFD codes estimate the pressure drop from the velocity profile which is obtained by solving momentum conservation equations, and the resulting friction factor can be a representative parameter for a constant cross section channel flow. In addition, the flow inside a rectangular channel with a high span to gap ratio can be approximated by flow inside parallel plates. The computational fluid dynamics simulation on the flow between parallel plates showed reasonable prediction capability for the laminar and the turbulent regime.

  16. Theoretical studying the stability of steady-state regime of a channel with a coolant condensation

    International Nuclear Information System (INIS)

    Savikhin, O.G.

    1987-01-01

    Based on the boiling channel stability theory, the channel steady-state stability with the coolant condensation is studied. Condensable coolants are used in the NPP steam-separator superheaters as well as in cryogenic technique. Under certain conditions the coolant flow rate and temperature fluctuations may be excited in the parallel channel system with coolant condensation, which produce a sufficient effect on the heat exchange equipment operation reliability. To describe unsteady processes of heat and mass transfer in the channel, a homogeneous two-phase flow one dimensional model is used. The results obtained allow one to make a conclusion concerning the effect of some parameters on condensing channel steady-state regime stability: reduction of inlet and outlet unheated communication length, pressure drop increase at the outlet plate and its reduction at the inlet one lead to the increase of stability margin

  17. Development of new bi-polar plates based on electrically conductive filled polymers for PEMFC

    Energy Technology Data Exchange (ETDEWEB)

    Jousse, F.; Salas, J.F.; Giroud, F. [C.E.A., Le Ripault, Monts (France); Icard, B.; Laurent, J.Y.; Serre Combe, P.

    2000-07-01

    In polymer electrolyte membrane fuel cell technology, the bi-polar plates are dedicated to: the current collection, the separation and distribution of gas (hydrogen and oxygen) at the cathode and the anode. To achieve these functions, bi-polar plate materials must satisfy the following properties: high conductivity (higher than 10 S/cm), high chemical resistance to acid and water, very low permeability to hydrogen (permeability < Pe{sup H2}{sub Nafion} (20 C) = 7.10{sup -17} m{sup 2}/Pa/s). Traditionally bi-polar plates have been designed with stainless steel or graphite. However, the cost of these plates are incompatible to transport applications, principally because of the gas channel machining step. Recently, we have noticed the work of T.M. Besmann [1] on the manufacturing of bi-polar plates based on carbon fibres and phenolic resin, processed by pyrolisis and densification on surface by a chemical vapour infiltration process. However, this kind of process seems too expensive and complex for the needs of the road electric transportation industry. Organic composites based on conductive chemical resistant fillers and processed by molding could be an alternative solution. Bi-polar plates requirements can be achieved by controlling and optimising experimental parameters such as the nature and morphology of fillers, the resin characteristics, and the process conditions. To avoid corrosion of the composite material, and then, the contamination of the cell, we have selected non metallic fillers, based on graphite or carbon black. (orig.)

  18. Part 1, Angular distribution measurement of beam-foil muonium, Part 2, Muon injection simulation for a new muon g-2 experiment

    International Nuclear Information System (INIS)

    Ahn, H.E.

    1992-10-01

    The angular and energy distributions of positive muons μ + and muonium M produced by the beam-foil method have been measured for the first time. A 7 MeV/c subsurface μ + beam was delivered to our apparatus from the Stopped Muon Channel at the Los Alamos Clinton P. Anderson Meson Physics Facility (LAMPF). The μ + formed M by electron capture in a thin Al target foil. A low pressure multi-wire proportional chamber upstream of the target foil was used both as a moderator and as a muon counter. To observe muonium, muons sere swept away by a bending magnet which was placed downstream of the target foil. This magnet was turned off while measuring the μ + distribution. Beyond the magnetic field, particles were collimated and then stopped by a microchannel plate detector located at various angles to the incident muon beam axis. Two pairs of scintillators mounted above (St) and below (Sb) the MC-P were used to detect the decay positrons to verify from the lifetime spectrum that the particles detected by the MCP are muons. The intensities of μ + and M emerging from the Al foil at different angles were obtained from both a time-of-flight spectrum and a lifetime spectrum

  19. Development of a secondary electron energy analyzer for a transmission electron microscope.

    Science.gov (United States)

    Magara, Hideyuki; Tomita, Takeshi; Kondo, Yukihito; Sato, Takafumi; Akase, Zentaro; Shindo, Daisuke

    2018-04-01

    A secondary electron (SE) energy analyzer was developed for a transmission electron microscope. The analyzer comprises a microchannel plate (MCP) for detecting electrons, a coil for collecting SEs emitted from the specimen, a tube for reducing the number of backscattered electrons incident on the MCP, and a retarding mesh for selecting the energy of SEs incident on the MCP. The detection of the SEs associated with charging phenomena around a charged specimen was attempted by performing electron holography and SE spectroscopy using the energy analyzer. The results suggest that it is possible to obtain the energy spectra of SEs using the analyzer and the charging states of a specimen by electron holography simultaneously.

  20. Modeling Oligo-Miocence channel sands (Dezful Embayment, SW Iran): an integrated facies classification workflow

    International Nuclear Information System (INIS)

    Heydari, Mostafa; Maddahi, Iradj; Moradpour, Mehran; Esmaeilpour, Sajjad

    2014-01-01

    This study has been conducted on Mansuri onshore oilfield located in Dezful Embayment, south-west Iran. One of the hydrocarbon-bearing formations is a Oligo-Miocene Asmari formation—the most prolific Iranian reservoir rock. Like many other oilfields in the area, the trap in this field is deemed structural (anticline), formed during the collision of the Arabian plate with the Iranian plate and the folding of Neotethys deposits with a NW–SE trend. This study integrates three different quantitative studies from geology, geophysics and petrophysics disciplines to quantitate ‘the qualitative study of seismic facies analysis based on trace shapes and 3D multi-attribute clustering’. First, stratigraphic sequences and seismic detectable facies were derived at one well location using the available high resolution core facies analysis and depositional environment assessment reports. Paleo and petrophysical logs from other wells were subsequently used for the extrapolation of stratigraphic sequences interpreted at the first well. Utilizing lithology discrimination obtained by wire-line log interpretation, facies were extrapolated to all wells in the area. Seismic 3D attribute analysis and seismic facies classification established a 3D facies volume accordingly, which was finally calibrated to geological facies at well locations. The ultimate extracted facies-guided geobody shows that good reservoir-quality channel sands have accumulated with NW/SE elongation at the ridge of the structure. As a result, this type of geometry has created a stratigraphic/structural hydrocarbon trap in this oilfield. Moreover, seismic facies analysis shows that buried channels do not parallel the predominant Arabian plate-originated channels (with SW–NE trends) in SW Zagros and are locally swerved in this area. (paper)

  1. Thermal Analysis of AlGaN/GaN High-Electron-Mobility Transistor and Its RF Power Efficiency Optimization with Source-Bridged Field-Plate Structure.

    Science.gov (United States)

    Kwak, Hyeon-Tak; Chang, Seung-Bo; Jung, Hyun-Gu; Kim, Hyun-Seok

    2018-09-01

    In this study, we consider the relationship between the temperature in a two-dimensional electron gas (2-DEG) channel layer and the RF characteristics of an AlGaN/GaN high-electron-mobility transistor by changing the geometrical structure of the field-plate. The final goal is to achieve a high power efficiency by decreasing the channel layer temperature. First, simulations were performed to compare and contrast the experimental data of a conventional T-gate head structure. Then, a source-bridged field-plate (SBFP) structure was used to obtain the lower junction temperature in the 2-DEG channel layer. The peak electric field intensity was reduced, and a decrease in channel temperature resulted in an increase in electron mobility. Furthermore, the gate-to-source capacitance was increased by the SBFP structure. However, under the large current flow condition, the SBFP structure had a lower maximum temperature than the basic T-gate head structure, which improved the device electron mobility. Eventually, an optimum position of the SBFP was used, which led to higher frequency responses and improved the breakdown voltages. Hence, the optimized SBFP structure can be a promising candidate for high-power RF devices.

  2. Core conversion from rod to plate type fuel elements in research reactors

    International Nuclear Information System (INIS)

    Khattab, M.S.; Mina, A.R.

    1997-01-01

    Core thermalhydraulic analysis have been performed for rod and plate types fuel elements without altering the core bundles square grid spacer (68 mm, side) and coolant mass flow rate. The U O 2 -Mg, 10% enrichment rod type fuel elements are replaced by the MTR plate type, U-Al alloy of 20% enrichment. Coolant mass flux increased from 2000 kg/m 2 S to 5000 kg/m 2 S. Reactor power could be upgraded from 2 to 10 MW without significantly altering the steady state, thermal-hydraulic safety margins. Fuel, clad and coolant transient temperatures are determined inside the core hot channel during flow coast down using paret code. Residual heat removal system of 20% coolant capacity is necessary for upgrading reactor power to encounter the case of pumps off at 10 MW nominal operation. 6 figs., 2 tabs

  3. Profile of circulating levels of IL-1Ra, CXCL10/IP-10, CCL4/MIP-1β and CCL2/MCP-1 in dengue fever and parvovirosis

    Directory of Open Access Journals (Sweden)

    Luzia Maria de-Oliveira-Pinto

    2012-02-01

    Full Text Available Dengue virus (DENV and parvovirus B19 (B19V infections are acute exanthematic febrile illnesses that are not easily differentiated on clinical grounds and affect the paediatric population. Patients with these acute exanthematic diseases were studied. Fever was more frequent in DENV than in B19V-infected patients. Arthritis/arthralgias with DENV infection were shown to be significantly more frequent in adults than in children. The circulating levels of interleukin (IL-1 receptor antagonist (Ra, CXCL10/inducible protein-10 (IP-10, CCL4/macrophage inflammatory protein-1 beta and CCL2/monocyte chemotactic protein-1 (MCP-1 were determined by multiplex immunoassay in serum samples obtained from B19V (37 and DENV-infected (36 patients and from healthy individuals (7. Forward stepwise logistic regression analysis revealed that circulating CXCL10/IP-10 tends to be associated with DENV infection and that IL-1Ra was significantly associated with DENV infection. Similar analysis showed that circulating CCL2/MCP-1 tends to be associated with B19V infection. In dengue fever, increased circulating IL-1Ra may exert antipyretic actions in an effort to counteract the already increased concentrations of IL-1β, while CXCL10/IP-10 was confirmed as a strong pro-inflammatory marker. Recruitment of monocytes/macrophages and upregulation of the humoral immune response by CCL2/MCP-1 by B19V may be involved in the persistence of the infection. Children with B19V or DENV infections had levels of these cytokines similar to those of adult patients.

  4. Alteração da eficiência do 1-MCP com o retardo na sua aplicação após a colheita em maçãs 'Fuji suprema' Changes of 1-MPC efficiency by delaying its postharvest application on 'Fuji suprema' apples

    Directory of Open Access Journals (Sweden)

    Cassandro Vidal Talamini do Amarante

    2010-12-01

    Full Text Available Estudos indicam que a eficiência do 1-metilciclopropeno (1-MCP para conservação pós-colheita de maçãs é máxima quando aplicado até uma semana após a colheita. No entanto, o carregamento das câmaras de armazenagem comerciais com maçãs 'Fuji' pode extender-se por mais de uma semana. Os efeitos da aplicação tardia do 1-MCP para maçãs 'Fuji' não têm sido reportados. Este trabalho teve por objetivo avaliar os efeitos do retardo na aplicação de 1-MCP, a partir da data de colheita, na preservação da firmeza de polpa, acidez titulável (AT e sólidos solúveis (SS, e na prevenção de escaldadura superficial, escurecimento da polpa e podridões em maçãs 'Fuji Suprema'. Os frutos foram colhidos em pomares comerciais do Estado de Santa Catarina, nas regiões de Fraiburgo (quatro pomares, Bom Retiro (três pomares e São Joaquim (três pomares, em abril de 2006. Os frutos foram refrigerados 12 h após a colheita e mantidos durante nove meses sob atmosfera do ar a 0,5 ± 0,5 ºC e 90-95% de UR. Os frutos foram tratados com ar (controle ou 1-MCP (1 µL.L-1, durante 24h, na mesma temperatura de armazenamento, aos 0; 4; 8; 12; 16 ou 20 dias após a colheita. A qualidade dos frutos foi determinada após o armazenamento refrigerado, mais sete dias a 23 ºC. O retardo na aplicação do 1-MCP, por até 20 dias após a colheita, não reduziu sua eficiência na conservação da firmeza da polpa e na prevenção do escurecimento da polpa e podridões, em frutos colhidos nas três regiões, bem como na preservação do teor de SS em frutos colhidos em Bom Retiro e São Joaquim. No entanto, a eficiência do 1-MCP sobre a prevenção da escaldadura superficial foi reduzida quando sua aplicação foi atrasada por 16 ou 20 dias a partir da data de colheita, especialmente nos frutos das regiões que apresentaram maior suscetibilidade ao distúrbio (Fraiburgo e São Joaquim. Os benefícios do 1-MCP sobre a conservação da AT foram reduzidos quando

  5. Radiation-hard ceramic Resistive Plate Chambers for forward TOF and T0 systems

    Energy Technology Data Exchange (ETDEWEB)

    Akindinov, A., E-mail: Alexander.Akindinov@cern.ch [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Dreyer, J.; Fan, X.; Kämpfer, B. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Kiselev, S. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Kotte, R.; Garcia, A. Laso [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Malkevich, D. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Naumann, L. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Nedosekin, A.; Plotnikov, V. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Stach, D. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Sultanov, R.; Voloshin, K. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation)

    2017-02-11

    Resistive Plate Chambers with ceramic electrodes are the main candidates for a use in precise multi-channel timing systems operating in high-radiation conditions. We report the latest R&D results on these detectors aimed to meet the requirements of the forward T0 counter at the CBM experiment. RPC design, gas mixture, limits on the bulk resistivity of ceramic electrodes, efficiency, time resolution, counting rate capabilities and ageing test results are presented.

  6. A Possible Differentially Shortened Strike-slip Plate Boundary: the Okhotsk Plate Example.

    Science.gov (United States)

    Hindle, D.; Egorov, V.; Mackey, K. G.; Fujita, K.

    2004-12-01

    The Okhotsk plate has been postulated based on a combination of GPS geodetic inversions (REVEL1), seimsicity, geologic and lineament data. Lying between the North American and Eurasian plates, its northwestern corner would appear to be undergoing compression in a scissors motion between the two bounding plates. Extrusion tectonics along multiple, large strike-slip faults within the Okhotsk plate itself have been suggested to allow the escape of material away from the apex of Eurasia-North America. The plate boundary between Okhotsk and North America has been suggested to be diffuse, based on widely scattered minor seismicity. However, the large, left lateral, Ulakhan fault has also been suggested as a candidate plate boundary. We present field geological and geomorphological evidence of the partitioning of deformation between the Ulakhan fault, and several parallel and oblique, linked faults. The Ulakhan fault strand appears to have a maximum displacement of 24 km based on river valley offsets and closing large pull apart basins. Some of the displacement from the Ulakhan fault appears relayed into the plate margin along oblique trending, thrust/oblique slip faults. Estimated shortening over these faults is equivalent to the amount of shortening relayed into the plate margin from the plate boundary. There may be several thrust/oblique slip faults along the Ulakhan fault, which leads to the interesting situation of a segmented, strike-slip plate boundary being actively shortened in a margin parallel direction. This may be the result of postulated extrusion of the Okhotsk plate due to North America/Eurasia convergence. Such a situation would have important consequences for the interpretation of GPS data in a plate tectonic context.

  7. Evaluation of Corrosion of the Dummy ''EE'' Plate 19 in YA Type ATR Fuel Element During Reactor PALM Cycles

    International Nuclear Information System (INIS)

    Brower, Jeffrey Owen; Glazoff, Michael Vasily; Eiden, Thomas John; Rezvoi, Aleksey Victor

    2016-01-01

    Advanced Test Reactor (ATR) Cycle 153B-1 was a 14-day, high-power, powered axial locator mechanism (PALM) operating cycle that completed on April 12, 2013. Cycle 153B-1 was a typical operating cycle for the ATR and did not result in any unusual plant transients. ATR was started up and shut down as scheduled. The PALM drive physically moves the selected experiments into and out of the core to simulate reactor startup and heat up, and shutdown and cooldown transients, while the reactor remains in steady state conditions. However, after the cycle was over, several thousand of the flow-assisted corrosion pits and ''horseshoeing'' defects were readily observable on the surface of the several YA-type fuel elements (these are ''dummy'' plates that contain no fuel). In order understand these corrosion phenomena a thermal-hydraulic model of coolant channel 20 on a YA-M fuel element was generated. The boundaries of the model were the aluminum EE plate of a YA-M fuel element and a beryllium reflector block with 13 horizontal saw cuts which represented regions of zero flow. The heat generated in fuel plates 1 through 18 was modeled to be passing through the aluminum EE plate. The coolant channel 20 width was set at 0.058 in. (58 mils). It was established that the horizontal saw cuts had a significant effect on the temperature of the coolant. The flow, which was expected to vary linearly with gradual heating of the coolant as it passed through the channel, was extremely turbulent. The temperature rise, which was expected to be a smooth ''S'' curve, was represented by a series temperature rise ''humps,'' which occurred at each horizontal saw cut in the beryllium reflector block. Each of the 13 saw cuts had a chamfered edge which resulted in the coolant flow being re-directed as a jet across the coolant channel into the surface of the EE plate, which explained the temperature rise and the observed sscalloping and possibly pitting degradation on the YA-M fuel elements. In the case

  8. KKL correlation for simulation of nanofluid flow and heat transfer in a permeable channel

    Energy Technology Data Exchange (ETDEWEB)

    Sheikholeslami Kandelousi, Mohsen, E-mail: m_sh_3750@yahoo.com

    2014-10-03

    Hydrothermal behavior of nanofluid fluid between two parallel plates is studied. One of the plates is externally heated, and the other plate, through which coolant fluid is injected, expands or contracts with time. The effective thermal conductivity and viscosity of nanofluid are calculated by KKL correlation. The effects of the nanoparticle volume fraction, Reynolds number, Expansion ratio and power law index on Hydrothermal behavior are investigated. Results show that heat transfer enhancement has direct relationship with Reynolds number when power law index is equals to zero but opposite trend is observed for other values of power law index. - Highlights: • Nanofluid Hydrothermal behavior in a porous channel is considered. • Nusselt number is an increasing function of ϕ, R and m. • Nusselt number is a decreasing function of α.

  9. Investigation of a Multi-Anode Microchannel Plate PMT for Time-of-Flight PET

    Science.gov (United States)

    Choong, Woon-Seng

    2010-10-01

    We report on an investigation of a mulit-anode microchannel plate PMT for time-of-flight PET detector modules. The primary advantages of an MCP lie in its excellent timing properties (fast rise time and low transit time spread), compact size, and reasonably large active area, thus making it a good candidate for TOF applications. In addition, the anode can be segmented into an array of collection electrodes with fine pitch to attain good position sensitivity. In this paper, we investigate using the Photonis Planacon MCP-PMT with a pore size of 10 μm to construct a PET detector module, specifically for time-of-flight applications. We measure the single electron response by exciting the Planacon with pulsed laser diode. We also measure the performance of the Planacon as a PET detector by coupling a 4 mm×4 mm×10 mm LSO crystal to individual pixel to study its gain uniformity, energy resolution, and timing resolution. The rise time of the Planacon is 440 ps with pulse duration of about 1 ns. A transit time spread of 120 ps FWHM is achieved. The gain is fairly uniform across the central region of the Planacon, but drops off by as much as a factor of 2.5 around the edges. The energy resolution is fairly uniform across the Planacon with an average value of 18.6 ± 0.7% FWHM. While the average timing resolution of 252 ± 7 ps FWHM is achieved in the central region of the Planacon, it degrades to 280 ± 9 ps FWHM for edge pixels and 316 ± 15 ps FWHM for corner pixels. We compare the results with measurements performed with a fast timing conventional PMT (Hamamatsu R-9800). We find that the R9800, which has significantly higher PDE, has a better timing resolution than the Planacon. Furthermore, we perform detector simulations to calculate the improvement that can be achieved with a higher PDE Planacon. The calculation shows that the Planacon can achieve significantly better timing resolution if it can attain the same PDE as the R-9800, while only a 30% improvement is

  10. Evaluation of Erosion of the Dummy ''EE'' Plate 19 in YA Type ATR Fuel Element During Reactor PALM Cycles

    International Nuclear Information System (INIS)

    Brower, Jeffrey O.; Glazoff, Michael V.; Eiden, Thomas J.; Rezvoi, Aleksey V.

    2016-01-01

    Advanced Test Reactor (ATR) Cycle 153B-1 was a 14-day, high-power, powered axial locator mechanism (PALM) operating cycle that completed on April 12, 2013. Cycle 153B-1 was a typical operating cycle for the ATR, and did not result in any unusual plant transients. ATR was started up and shut down as scheduled. The PALM drive physically moves the selected experiments into and out of the core to simulate reactor startup and heat up, and shutdown and cooldown transients, while the reactor remains in steady-state conditions. However, after the cycle was over, when the fuel elements were removed from the core and inspected, several thousand flow-assisted erosion pits and ''horseshoeing'' defects were readily observed on the surface of the several YA-type fuel elements (these are aluminum ''dummy'' plates that contain no fuel). In order to understand these erosion phenomena, a thermal-hydraulic model of coolant channel 20 on a YA-M fuel element was generated. The boundaries of the model were the aluminum EE plate of a YA-M fuel element and a beryllium reflector block with 13 horizontal saw cuts which represented regions of zero flow. The heat generated in fuel plates 1 through 18 was modeled to be passing through the aluminum EE plate. The coolant channel 20 width was set at 0.058 in. (58 mils). It was established that the horizontal saw cuts had a significant effect on the temperature of the coolant. The flow, which was expected to vary linearly with gradual heating of the coolant as it passed through the channel, was extremely turbulent. The temperature rise, which was expected to be a smooth ''S'' curve, was represented by a series temperature rise ''humps,'' which occurred at each horizontal saw cut in the beryllium reflector block. Each of the 13 saw cuts had a chamfered edge which resulted in the coolant flow being re-directed as a jet across the coolant channel into the surface of the EE plate, which explained the temperature rise and the observed scalloping and

  11. Flow rate-pressure drop relation for deformable shallow microfluidic channels

    Science.gov (United States)

    Christov, Ivan C.; Cognet, Vincent; Shidhore, Tanmay C.; Stone, Howard A.

    2018-04-01

    Laminar flow in devices fabricated from soft materials causes deformation of the passage geometry, which affects the flow rate--pressure drop relation. For a given pressure drop, in channels with narrow rectangular cross-section, the flow rate varies as the cube of the channel height, so deformation can produce significant quantitative effects, including nonlinear dependence on the pressure drop [{Gervais, T., El-Ali, J., G\\"unther, A. \\& Jensen, K.\\ F.}\\ 2006 Flow-induced deformation of shallow microfluidic channels.\\ \\textit{Lab Chip} \\textbf{6}, 500--507]. Gervais et. al. proposed a successful model of the deformation-induced change in the flow rate by heuristically coupling a Hookean elastic response with the lubrication approximation for Stokes flow. However, their model contains a fitting parameter that must be found for each channel shape by performing an experiment. We present a perturbation approach for the flow rate--pressure drop relation in a shallow deformable microchannel using the theory of isotropic quasi-static plate bending and the Stokes equations under a lubrication approximation (specifically, the ratio of the channel's height to its width and of the channel's height to its length are both assumed small). Our result contains no free parameters and confirms Gervais et. al.'s observation that the flow rate is a quartic polynomial of the pressure drop. The derived flow rate--pressure drop relation compares favorably with experimental measurements.

  12. Flow reversal in combined laminar mixed convection heat and mass transfer with phase change in a vertical channel

    International Nuclear Information System (INIS)

    Oulaid, Othmane; Benhamou, Brahim; Galanis, Nicolas

    2010-01-01

    This paper, deals with a numerical study of the effects of buoyancy forces on an upward, steady state, laminar flow of humid air in a vertical parallel-plate channel. The plates are wetted by a thin liquid water film and maintained at a constant temperature which is lower than that of the air entering the channel. A 2D fully elliptical model, associated with the Boussinesq assumption, is used to take into account axial diffusion. The solution of this mathematical model is based on the finite volume method and the velocity-pressure coupling is handled by the SIMPLER algorithm. Numerical results show that buoyancy forces have a significant effect on the hydrodynamic, thermal and mass fraction fields. Additionally, these forces induce flow reversal for high air temperatures and mass fractions at the channel entrance. It is established that heat transfer associated with phase change is, sometimes, more significant than sensible heat transfer. Furthermore, this importance depends on the mass fraction gradient. The conditions for the existence of flow reversal are presented in charts and analytical expressions specifying the critical thermal Grashof number as a function of the Reynolds number for different values of the solutal Grashof number and different aspect ratios of the channel.

  13. TORCH: A Large-Area Detector for Precision Time-of-Flight Measurements at LHCb

    CERN Document Server

    Harnew, N

    2012-01-01

    The TORCH (Time Of internally Reflected CHerenkov light) is an innovative high-precision time-of-flight detector which is suitable for large areas, up to tens of square metres, and is being developed for the upgraded LHCb experiment. The TORCH provides a time-of-flight measurement from the imaging of photons emitted in a 1 cm thick quartz radiator, based on the Cherenkov principle. The photons propagate by total internal reflection to the edge of the quartz plane and are then focused onto an array of Micro-Channel Plate (MCP) photon detectors at the periphery of the detector. The goal is to achieve a timing resolution of 15 ps per particle over a flight distance of 10 m. This will allow particle identification in the challenging momentum region up to 20 GeV/c. Commercial MCPs have been tested in the laboratory and demonstrate the required timing precision. An electronics readout system based on the NINO and HPTDC chipset is being developed to evaluate an 8×8 channel TORCH prototype. The simulated performance...

  14. Influence of 1-MCP on texture, related enzymes, quality and their relative gene expression in 'Amrapali' mango (Mangifera indica L.) fruits.

    Science.gov (United States)

    Reddy, S V R; Sharma, R R; Barthakur, S

    2017-11-01

    The mango fruits remain biologically active even after harvest as they continue respiration, transpiration and other bio-chemical processes. Being highly perishable, the fruit quality deteriorates fast under ambient conditions (30 ± 5 °C and 50 ± 5% RH), rendering them unmarketable within 5-6 days. In order to extend the shelf-life of 'Amrapali' mango fruits, we have treated them with three different concentrations (500, 750 and 1000 ppb) of 1-Methylcyclopropene (1-MCP) @ 20 °C and stored at ambient conditions. Among all the treatments, 1000 ppb was found to be an effective in extending shelf-life till twelfth day with minimum physiological loss in weight (19.24%), maximum firmness (10.43 N), highest retention of quality parameters such as soluble solid concentrates (27.88 °B), ascorbic acid (28.49 mg 100 g -1 FW) and total antioxidant activity (675.41 µmol Trolox g -1 FW) compared to untreated mango fruits (21.79%, 5.45 N, 23.17 °B, 19.55 mg 100 g -1 FW and 265.41 µmol Trolox g -1 FW, respectively). Gene expression studies have revealed that the texture related gene expansin was significantly repressed till fifth day of storage with increasing concentrations of 1-MCP.

  15. Effect of Plate Curvature on Blast Response of Structural Steel Plates

    Science.gov (United States)

    Veeredhi, Lakshmi Shireen Banu; Ramana Rao, N. V.; Veeredhi, Vasudeva Rao

    2018-04-01

    In the present work an attempt is made, through simulation studies, to determine the effect of plate curvature on the blast response of a door structure made of ASTM A515 grade 50 steel plates. A door structure with dimensions of 5.142 m × 2.56 m × 10 mm having six different radii of curvatures is analyzed which is subjected to blast load. The radii of curvature investigated are infinity (flat plate), 16.63, 10.81, 8.26, 6.61 and 5.56 m. In the present study, a stand-off distance of 11 m is considered for all the cases. Results showed that the door structure with smallest radius of curvature experienced least plastic deformation and yielding when compared to a door with larger radius of curvature with same projected area. From the present Investigation, it is observed that, as the radius of curvature of the plate increases, the deformation mode gradually shifts from indentation mode to flexural mode. The plates with infinity and 16.63 m radius of curvature have undergone flexural mode of deformation and plates with 6.61 and 5.56 m radius of curvature undergo indentation mode of deformation. Whereas, mixed mode of deformation that consists of both flexural and indentation mode of deformations are seen in the plates with radius of curvature 10.81 and 8.26 m. As the radius of curvature of the plate decreases the ability of the plate to mitigate the effect the blast loads increased. It is observed that the plate with smaller radius of curvature deflects most of the blast energy and results in least indentation mode of deformation. The most significant observation made in the present investigation is that the strain energy absorbed by the steel plate gets reduced to 1/3 rd when the radius of curvature is approximately equal to the stand-off distance which could be the critical radius of curvature.

  16. The Okhotsk Plate and the Eurasia-North America plate boundary zone.

    Science.gov (United States)

    Hindle, David; Mackey, Kevin

    2014-05-01

    The Eurasia-North America plate boundary zone transitions from spreading at rates of ~ 25mm/yr in the North Atlantic, to compression at rates of ~ 5mm/yr in the region of the Okhotsk plate. Because the pole of rotation between Eurasia and North America lies more or less on their mutual boundary, there is a linear change in rate along the boundary, and regions near the euler pole are subject to extremely low deformation rates. The Okhotsk - Eurasia - North America triple junction lies slightly south of the rotation pole, placing the Okhotsk plate entirely in a weakly contractional setting. Regions near the triple junction absorb 1mm/yr contraction. Further south, towards the shoreline of the Okhotsk sea, up to 5 mm/yr contraction may be absorbed within the plate. How shortening is accommodated across the boundary remains an open question. One possibility is wholesale extrusion of the entire Okhotsk plate (or possibly its northwestern corner) along two plate boundary strike slip faults (Eurasia-Okhostk and North America Okhotsk). The problem with this model is that the seismic record does not presently clearly support it, with the largest events distributed both within the plate interior and on its boundaries. This may suggest that instead, the Okhotsk plate, and particularly its north-western end, consists of a series of smaller blocks which shuffle against each other, partially accommodating extrusion, but also permitting some internal deformation and change of shape of the Okhotsk plate itself. We present analyses of the very sparse seismic record from the region, as well as geometric-kinematic, tectonic models of the possible deformation of northwest Okhotsk to try to better understand the different probabilities of how this slowly deforming plate boundary zone is behaving.

  17. SU-F-19A-03: Dosimetric Advantages in Critical Structure Dose Sparing by Using a Multichannel Cylinder in High Dose Rate Brachytherapy to Treat Vaginal Cuff Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Syh, J; Syh, J; Patel, B; Zhang, J; Wu, H; Rosen, L [Willis-Knighton Cancer Center, Shreveport, LA (United States)

    2014-06-15

    Purpose: The multichannel cylindrical vaginal applicator is a variation of traditional single channel cylindrical vaginal applicator. The multichannel applicator has additional peripheral channels that provide more flexibility in the planning process. The dosimetric advantage is to reduce dose to adjacent organ at risk (OAR) such as bladder and rectum while maintaining target coverage with the dose optimization from additional channels. Methods: Vaginal HDR brachytherapy plans are all CT based. CT images were acquired in 2 mm thickness to keep integrity of cylinder contouring. The CTV of 5mm Rind with prescribed treatment length was reconstructed from 5mm expansion of inserted cylinder. The goal was 95% of CTV covered by 95% of prescribed dose in both single channel planning (SCP)and multichannel planning (MCP) before proceeding any further optimization for dose reduction to critical structures with emphasis on D2cc and V2Gy . Results: This study demonstrated noticeable dose reduction to OAR was apparent in multichannel plans. The D2cc of the rectum and bladder were showing the reduced dose for multichannel versus single channel. The V2Gy of the rectum was 93.72% and 83.79% (p=0.007) for single channel and multichannel respectively (Figure 1 and Table 1). To assure adequate coverage to target while reducing the dose to the OAR without any compromise is the main goal in using multichannel vaginal applicator in HDR brachytherapy. Conclusion: Multichannel plans were optimized using anatomical based inverse optimization algorithm of inverse planning simulation annealing. The optimization solution of the algorithm was to improve the clinical target volume dose coverage while reducing the dose to critical organs such as bladder, rectum and bowels. The comparison between SCP and MCP demonstrated MCP is superior to SCP where the dwell positions were based on geometric array only. It concluded that MCP is preferable and is able to provide certain features superior to SCP.

  18. Efeito do 1-metilciclopropeno sobre a emissão dos ésteres voláteis de bananas ao longo do amadurecimento Efferct of 1-MCP on esters volatiles eission of bananas along the ripening

    Directory of Open Access Journals (Sweden)

    Baraquizio Braga do Nascimento Junior

    2008-01-01

    Full Text Available Fresh green bananas (Musa sp., subgroup Prata were treated with a dose of only 90 ηg g-1 of 1-MCP for 13 hours and the evolution of the volatile compounds along the ripeness was studied. A method to quantify the emission of esters was developed by cryogenic headspace and gas chromatography. Esters of acetate, butyrate, isobutyrate and isovalerate were found as major compounds. The application of the 1-MCP for 13 hours delayed the appearance of the coloration 8 of the peel for 3 days and decreased quantitatively in about 46% the total production of esters in the banana until the 15° day of harvested.

  19. A STUDY ON THE APPLICATION OF THE ECAP TO SURFACE PLATING

    Directory of Open Access Journals (Sweden)

    Osman KONUK

    2014-01-01

    Full Text Available Metal forming processes with shear stresses that very high plastic strains are obtained in one pass are defined as severe plastic deformation (SPD processes. Strain values can additionally be increased with additional passes throughout the process. Equal channel angular processing (ECAP is the most applied method among the SPD processes. In the presented study, an approach of application of ECAP method was used in surface plating. Previously manufactured ECAP dies using separated die design approach were used in the study. 5083 Aluminum and Ms 58 Brass alloy strips having 2 and 4 mm thickness were placed in the ECAP die side by side and processed with single and double passes in order to model the metallic plating under cold pressure welding conditions. There were no successful and full joints between the strips although some partial joints were observed. The results were discussed and some suggestions are made in order to obtain successful joints.

  20. The effect of a HfO2 insulator on the improvement of breakdown voltage in field-plated GaN-based HEMT

    International Nuclear Information System (INIS)

    Mao Wei; Hao Yue; Ma Xiao-Hua; Wang Chong; Zhang Jin-Cheng; Liu Hong-Xia; Bi Zhi-Wei; Xu Sheng-Rui; Yang Lin-An; Yang Ling; Zhang Kai; Zhang Nai-Qian; Pei Yi; Yang Cui

    2011-01-01

    A GaN/Al 0.3 Ga 0.7 N/AlN/GaN high-electron mobility transistor utilizing a field plate (with a 0.3 μm overhang towards the drain and a 0.2 μm overhang towards the source) over a 165-nm sputtered HfO 2 insulator (HfO 2 -FP-HEMT) is fabricated on a sapphire substrate. Compared with the conventional field-plated HEMT, which has the same geometric structure but uses a 60-nm SiN insulator beneath the field plate (SiN-FP-HEMT), the HfO 2 -FP-HEMT exhibits a significant improvement of the breakdown voltage (up to 181 V) as well as a record field-plate efficiency (up to 276 V/μm). This is because the HfO 2 insulator can further improve the modulation of the field plate on the electric field distribution in the device channel, which is proved by the numerical simulation results. Based on the simulation results, a novel approach named the proportional design is proposed to predict the optimal dielectric thickness beneath the field plate. It can simplify the field-plated HEMT design significantly. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  1. Three new species of the armored catfish genus Loricaria (Siluriformes: Loricariidae from river channels of the Amazon basin

    Directory of Open Access Journals (Sweden)

    Matthew R. Thomas

    Full Text Available Three new species of Loricaria are described from large white- and black-water river channels of the Amazon basin of Brazil, the upper rio Negro drainage of southern Venezuela, and clear waters of the lower rio Tocantins. Loricaria spinulifera and L. pumila differ from other species of Loricaria by having unique patterns of abdominal plate development and hypertrophied odontodes forming conspicuous crests on dorsal surfaces of the head and predorsal plates. Both are small species of Loricaria, reaching sexual maturity at less than 120 mm SL, and exhibiting sexually dimorphic characters consistent with members of the L. cataphracta complex. Loricaria spinulifera differs from L. pumila in having a unique arrangement of buccal papillae and large thorn-like odontodes on the dorsum of the head. Loricaria pumila is the smallest known Loricaria, reaching sexual maturity at less than 80 mm SL. Loricaria lundbergi differs from other Loricaria by having a unique abdominal plate pattern, broad head, and small basicaudal plate. Loricaria lundbergi is sympatric with L. spinulifera in the lower rio Negro drainage, but is also known from the rio Baria system of the Casiquiare drainage. Loricaria pumila occurs in the lower rio Amazonas and lower rio Tocantins. All three new species exhibit varying degrees of reduction in eye size and pigmentation seen in other fishes inhabiting deep river channels of South America.

  2. Finite element analysis of a solar collector plate using two plate geometries

    Directory of Open Access Journals (Sweden)

    Diego Manuel Medina Carril

    2016-09-01

    Full Text Available The thermal behavior of an absorber plate in a solar collector is investigated using finite element analysis. The thermal behavior and efficiency of two absorber plate geometries are studied, using a typical solar collector with a rectangular profile as reference, and a proposed absorber plate with curved geometry. An analysis of the most important parameters involved in the design of the absorber plate was carried out, indicating that the curved geometry of the absorber plate yields an average efficiency ~25% higher than the conventional rectangular geometry. The results suggest that a curved profile made of materials such as aluminum with thermal conductivity higher than 200W/m°C, plate thickness of the order of 2-3mm and with a large density of tubes per unit area of the collector´s plate greatly benefits the thermal efficiency of the solar collector.

  3. Investigation of thermal energy transport from an anisotropic central heating element to the adjacent channels: A multipoint flux approximation

    KAUST Repository

    Salama, Amgad

    2015-02-01

    The problem of heat transfer from a central heating element pressed between two clad plates to cooling channels adjacent and outboard of the plates is investigated numerically. The aim of this work is to highlight the role of thermal conductivity anisotropy of the heating element and/or the encompassing plates on thermal energy transport to the fluid passing through the two channels. When the medium is anisotropic with respect to thermal conductivity; energy transport to the neighboring channels is no longer symmetric. This asymmetry in energy fluxes influence heat transfer to the coolant resulting in different patterns of temperature fields. In particular, it is found that the temperature fields are skewed towards the principal direction of anisotropy. In addition, the heat flux distributions along the edges of the heating element are also different as a manifestation of thermal conductivity anisotropy. Furthermore, the peak temperature at the channel walls change location and magnitude depending on the principal direction of anisotropy. Based on scaling arguments, it is found that, the ratio of width to the height of the heating system is a key parameter which can suggest when one may ignore the effect of the cross-diagonal terms of the full conductivity tensor. To account for anisotropy in thermal conductivity, the method of multipoint flux approximation (MPFA) is employed. Using this technique, it is possible to find a finite difference stencil which can handle full thermal conductivity tensor and in the same time enjoys the simplicity of finite difference approximation. Although the finite difference stencil based on MPFA is quite complex, in this work we apply the recently introduced experimenting field approach which construct the global problem automatically.

  4. Evaluation of Corrosion of the Dummy “EE” Plate 19 in YA Type ATR Fuel Element During Reactor PALM Cycles

    Energy Technology Data Exchange (ETDEWEB)

    Brower, Jeffrey Owen [Idaho National Lab. (INL), Idaho Falls, ID (United States); Glazoff, Michael Vasily [Idaho National Lab. (INL), Idaho Falls, ID (United States); Eiden, Thomas John [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rezvoi, Aleksey Victor [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-08-01

    Advanced Test Reactor (ATR) Cycle 153B-1 was a 14-day, high-power, powered axial locator mechanism (PALM) operating cycle that completed on April 12, 2013. Cycle 153B-1 was a typical operating cycle for the ATR and did not result in any unusual plant transients. ATR was started up and shut down as scheduled. The PALM drive physically moves the selected experiments into and out of the core to simulate reactor startup and heat up, and shutdown and cooldown transients, while the reactor remains in steady state conditions. However, after the cycle was over, several thousand of the flow-assisted corrosion pits and “horseshoeing” defects were readily observable on the surface of the several YA-type fuel elements (these are “dummy” plates that contain no fuel). In order understand these corrosion phenomena a thermal-hydraulic model of coolant channel 20 on a YA-M fuel element was generated. The boundaries of the model were the aluminum EE plate of a YA-M fuel element and a beryllium reflector block with 13 horizontal saw cuts which represented regions of zero flow. The heat generated in fuel plates 1 through 18 was modeled to be passing through the aluminum EE plate. The coolant channel 20 width was set at 0.058 in. (58 mils). It was established that the horizontal saw cuts had a significant effect on the temperature of the coolant. The flow, which was expected to vary linearly with gradual heating of the coolant as it passed through the channel, was extremely turbulent. The temperature rise, which was expected to be a smooth “S” curve, was represented by a series temperature rise “humps,” which occurred at each horizontal saw cut in the beryllium reflector block. Each of the 13 saw cuts had a chamfered edge which resulted in the coolant flow being re-directed as a jet across the coolant channel into the surface of the EE plate, which explained the temperature rise and the observed sscalloping and possibly pitting degradation on the YA-M fuel elements. In

  5. Solar thermoelectric cooling using closed loop heat exchangers with macro channels

    Science.gov (United States)

    Atta, Raghied M.

    2017-07-01

    In this paper we describe the design, analysis and experimental study of an advanced coolant air conditioning system which cools or warms airflow using thermoelectric (TE) devices powered by solar cells. Both faces of the TE devices are directly connected to closed-loop highly efficient channels plates with macro scale channels and liquid-to-air heat exchangers. The hot side of the system consists of a pump that moves a coolant through the hot face of the TE modules, a radiator that drives heat away into the air, and a fan that transfer the heat over the radiator by forced convection. The cold side of the system consists also of a pump that moves coolant through the cold face of the TE modules, a radiator that drives cold away into the air, and a fan that blows cold air off the radiator. The system was integrated with solar panels, tested and its thermal performance was assessed. The experimental results verify the possibility of heating or cooling air using TE modules with a relatively high coefficient of performance (COP). The system was able to cool a closed space of 30 m3 by 14 °C below ambient within 90 min. The maximum COP of the whole system was 0.72 when the TE modules were running at 11.2 Å and 12 V. This improvement in the system COP over the air cooled heat sink is due to the improvement of the system heat exchange by means of channels plates.

  6. Plate removal following orthognathic surgery.

    Science.gov (United States)

    Little, Mhairi; Langford, Richard Julian; Bhanji, Adam; Farr, David

    2015-11-01

    The objectives of this study are to determine the removal rates of orthognathic plates used during orthognathic surgery at James Cook University Hospital and describe the reasons for plate removal. 202 consecutive orthognathic cases were identified between July 2004 and July 2012. Demographics and procedure details were collected for these patients. Patients from this group who returned to theatre for plate removal between July 2004 and November 2012 were identified and their notes were analysed for data including reason for plate removal, age, smoking status, sex and time to plate removal. 3.2% of plates were removed with proportionally more plates removed from the mandible than the maxilla. 10.4% of patients required removal of one or more plate. Most plates were removed within the first post-operative year. The commonest reasons for plate removal were plate exposure and infection. The plate removal rates in our study are comparable to those seen in the literature. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  7. Analysis of the modulation mechanisms of the electric field and breakdown performance in AlGaN/GaN HEMT with a T-shaped field-plate

    Science.gov (United States)

    Mao, Wei; Fan, Ju-Sheng; Du, Ming; Zhang, Jin-Feng; Zheng, Xue-Feng; Wang, Chong; Ma, Xiao-Hua; Zhang, Jin-Cheng; Hao, Yue

    2016-12-01

    A novel AlGaN/GaN high electron mobility transistor (HEMT) with a source-connected T-shaped field-plate (ST-FP HEMT) is proposed for the first time in this paper. The source-connected T-shaped field-plate (ST-FP) is composed of a source-connected field-plate (S-FP) and a trench metal. The physical intrinsic mechanisms of the ST-FP to improve the breakdown voltage and the FP efficiency and to modulate the distributions of channel electric field and potential are studied in detail by means of two-dimensional numerical simulations with Silvaco-ATLAS. A comparison to the HEMT and the HEMT with an S-FP (S-FP HEMT) shows that the ST-FP HEMT could achieve a broader and more uniform channel electric field distribution with the help of a trench metal, which could increase the breakdown voltage and the FP efficiency remarkably. In addition, the relationship between the structure of the ST-FP, the channel electric field, the breakdown voltage as well as the FP efficiency in ST-FP HEMT is analyzed. These results could open up a new effective method to fabricate high voltage power devices for the power electronic applications. Project supported by the National Natural Science Foundation of China (Grant Nos. 61574112, 61334002, 61306017, 61474091, and 61574110) and the Natural Science Basic Research Plan in Shaanxi Province, China (Grant No. 605119425012).

  8. Evaluation of Erosion of the Dummy “EE” Plate 19 in YA Type ATR Fuel Element During Reactor PALM Cycles

    Energy Technology Data Exchange (ETDEWEB)

    Brower, Jeffrey O. [Idaho National Lab. (INL), Idaho Falls, ID (United States). Advanced Test Reactor; Glazoff, Michael V. [Idaho National Lab. (INL), Idaho Falls, ID (United States). Advanced Test Reactor; Eiden, Thomas J. [Idaho National Lab. (INL), Idaho Falls, ID (United States). Advanced Test Reactor; Rezvoi, Aleksey V. [Idaho National Lab. (INL), Idaho Falls, ID (United States). Advanced Test Reactor

    2016-08-01

    Advanced Test Reactor (ATR) Cycle 153B-1 was a 14-day, high-power, powered axial locator mechanism (PALM) operating cycle that completed on April 12, 2013. Cycle 153B-1 was a typical operating cycle for the ATR, and did not result in any unusual plant transients. ATR was started up and shut down as scheduled. The PALM drive physically moves the selected experiments into and out of the core to simulate reactor startup and heat up, and shutdown and cooldown transients, while the reactor remains in steady-state conditions. However, after the cycle was over, when the fuel elements were removed from the core and inspected, several thousand flow-assisted erosion pits and “horseshoeing” defects were readily observed on the surface of the several YA-type fuel elements (these are aluminum “dummy” plates that contain no fuel). In order to understand these erosion phenomena, a thermal-hydraulic model of coolant channel 20 on a YA-M fuel element was generated. The boundaries of the model were the aluminum EE plate of a YA-M fuel element and a beryllium reflector block with 13 horizontal saw cuts which represented regions of zero flow. The heat generated in fuel plates 1 through 18 was modeled to be passing through the aluminum EE plate. The coolant channel 20 width was set at 0.058 in. (58 mils). It was established that the horizontal saw cuts had a significant effect on the temperature of the coolant. The flow, which was expected to vary linearly with gradual heating of the coolant as it passed through the channel, was extremely turbulent. The temperature rise, which was expected to be a smooth “S” curve, was represented by a series temperature rise “humps,” which occurred at each horizontal saw cut in the beryllium reflector block. Each of the 13 saw cuts had a chamfered edge which resulted in the coolant flow being re-directed as a jet across the coolant channel into the surface of the EE plate, which explained the temperature rise and the observed

  9. CFD SIMULATION OF THE HEAT TRANSFER PROCESS IN A CHEVRON PLATE HEAT EXCHANGER USING THE SST TURBULENCE MODEL

    Directory of Open Access Journals (Sweden)

    Jan Skočilas

    2015-08-01

    Full Text Available This paper deals with a computational fluid dynamics (CFD simulation of the heat transfer process during turbulent hot water flow between two chevron plates in a plate heat exchanger. A three-dimensional model with the simplified geometry of two cross-corrugated channels provided by chevron plates, taking into account the inlet and outlet ports, has been designed for the numerical study. The numerical model was based on the shear-stress transport (SST k-! model. The basic characteristics of the heat exchanger, as values of heat transfer coefficient and pressure drop, have been investigated. A comparative analysis of analytical calculation results, based on experimental data obtained from literature, and of the results obtained by numerical simulation, has been carried out. The coefficients and the exponents in the design equations for the considered plates have been arranged by using simulation results. The influence on the main flow parameters of the corrugation inclination angle relative to the flow direction has been taken into account. An analysis of the temperature distribution across the plates has been carried out, and it has shown the presence of zones with higher heat losses and low fluid flow intensity.

  10. Bending and stretching of plates

    CERN Document Server

    Mansfield, E H; Hemp, W S

    1964-01-01

    The Bending and Stretching of Plates deals with elastic plate theory, particularly on small- and large-deflexion theory. Small-deflexion theory concerns derivation of basic equations, rectangular plates, plates of various shapes, plates whose boundaries are amenable to conformal transformation, plates with variable rigidity, and approximate methods. Large-deflexion theory includes general equations and some exact solutions, approximate methods in large-deflexion theory, asymptotic large-deflexion theories for very thin plates. Asymptotic theories covers membrane theory, tension field theory, a

  11. Effect of the immersion in 1-MCP on the physicochemical and physiological properties of yellow pitahaya fruit (Selenicereus megalanthus How with minimum processing

    Directory of Open Access Journals (Sweden)

    Segura Rojas Diego Fernando

    2011-09-01

    Full Text Available

    La pitahaya amarilla (Selenicereus megalanthus How es una fruta exótica con gran potencial comercial. No obstante, sólo ha sido aprovechada comercialmente como fruta entera, sin procedimientos que le den valor agregado y mayor tiempo de vida de anaquel. En este trabajo se evaluó la aplicación de 200 mg/lt de 1-MCP en pitahaya amarilla mínimamente procesada (rodajas con cáscara y sin cáscara, empacada al vacío y almacenada bajo refrigeración, sobre la intensidad respiratoria y parámetros de calidad como sólidos solubles, acidez total titulable, pérdida de peso, azücares totales, firmeza y color. La aplicación de 1-MCP aumentó la producción de CO2, lo cual se manifestó en mayores contenidos de sólidos solubles y azúcares totales, pero no incidió en la pérdida de peso, variación de la acidez total titulable, cambios de color y retención de la firmeza. En ambos tipos de procesamientos se logró reducir durante el almacenamiento la pérdida de vitamina C.

  12. A compact Ultra-High Vacuum (UHV) compatible instrument for time of flight-energy measurements of slow heavy reaction products

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsov, A.V.; Veldhuizen, E.J. van; Westerberg, L.; Lyapin, V.G.; Aleklett, K.; Loveland, W.; Bondorf, J.; Jakobsson, B.; Whitlow, H.J.; El Bouanani, M

    2000-10-01

    A compact Ultra-High Vacuum (UHV) compatible instrument for time of flight-energy measurements of slow heavy reaction products from nuclear reactions has been designed and tested at the CELSIUS storage ring in Uppsala. The construction is based on MicroChannel Plate (MCP) time detectors of the electron mirror type and silicon p-i-n diodes, and permits the detectors to be stacked side-by-side to achieve large solid angle coverage. This kind of telescope measures the Time of Flight (ToF) and Energy (E) of the particle from which one can reconstruct mass. The combination of an ultra-thin cluster gas-jet target and thin carbon emitter foils allows one to measure heavy residues down to an energy of {approx}35 keV/nucleon from the interactions of 400 MeV/nucleon {sup 16}O with {sup nat}Xe gas targets.

  13. A compact Ultra-High Vacuum (UHV) compatible instrument for time of flight-energy measurements of slow heavy reaction products

    International Nuclear Information System (INIS)

    Kuznetsov, A.V.; Veldhuizen, E.J. van; Westerberg, L.; Lyapin, V.G.; Aleklett, K.; Loveland, W.; Bondorf, J.; Jakobsson, B.; Whitlow, H.J.; El Bouanani, M.

    2000-01-01

    A compact Ultra-High Vacuum (UHV) compatible instrument for time of flight-energy measurements of slow heavy reaction products from nuclear reactions has been designed and tested at the CELSIUS storage ring in Uppsala. The construction is based on MicroChannel Plate (MCP) time detectors of the electron mirror type and silicon p-i-n diodes, and permits the detectors to be stacked side-by-side to achieve large solid angle coverage. This kind of telescope measures the Time of Flight (ToF) and Energy (E) of the particle from which one can reconstruct mass. The combination of an ultra-thin cluster gas-jet target and thin carbon emitter foils allows one to measure heavy residues down to an energy of ∼35 keV/nucleon from the interactions of 400 MeV/nucleon 16 O with nat Xe gas targets

  14. Low energy electron microscopy imaging using Medipix2 detector

    International Nuclear Information System (INIS)

    Sikharulidze, I.; Gastel, R. van; Schramm, S.; Abrahams, J.P.; Poelsema, B.; Tromp, R.M.; Molen, S.J. van der

    2011-01-01

    Low Energy Electron Microscopy (LEEM) and Photo-Emission Electron Microscopy (PEEM) predominantly use a combination of microchannel plate (MCP), phosphor screen and optical camera to record images formed by 10-20 keV electrons. We have tested the performance of a LEEM/PEEM instrument with a Medipix2 hybrid pixel detector using an Ir(1 1 1) sample with graphene flakes grown on its surface. We find that Medipix2 offers a number of advantages over the MCP. The adjustable threshold settings allow Medipix2 to operate as a noiseless detector, offering an improved signal-to-noise ratio for the same amount of signal compared to the MCP. At the same magnification Medipix2 images exhibit superior resolution and can handle significantly higher electron current densities than an MCP, offering the prospect of substantially higher frame rates in LEEM imaging. These factors make Medipix2 an excellent candidate to become the detector of choice for LEEM/PEEM applications.

  15. Low energy electron microscopy imaging using Medipix2 detector

    Energy Technology Data Exchange (ETDEWEB)

    Sikharulidze, I., E-mail: irakli@chem.leidenuniv.nl [Leiden Institute of Chemistry, Leiden University, P.O. Box 9502, 2300RA Leiden (Netherlands); Gastel, R. van [MESA Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500AE Enschede (Netherlands); Schramm, S. [Kamerlingh Onnes Laboratory, Leiden University, P.O. Box 9504, 2300RA Leiden (Netherlands); Abrahams, J.P. [Leiden Institute of Chemistry, Leiden University, P.O. Box 9502, 2300RA Leiden (Netherlands); Poelsema, B. [MESA Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500AE Enschede (Netherlands); Tromp, R.M. [Kamerlingh Onnes Laboratory, Leiden University, P.O. Box 9504, 2300RA Leiden (Netherlands); IBM Research Division, T. J. Watson Research Center, P.O. Box 218, Yorktown Heights, NY 10598 (United States); Molen, S.J. van der [Kamerlingh Onnes Laboratory, Leiden University, P.O. Box 9504, 2300RA Leiden (Netherlands)

    2011-05-15

    Low Energy Electron Microscopy (LEEM) and Photo-Emission Electron Microscopy (PEEM) predominantly use a combination of microchannel plate (MCP), phosphor screen and optical camera to record images formed by 10-20 keV electrons. We have tested the performance of a LEEM/PEEM instrument with a Medipix2 hybrid pixel detector using an Ir(1 1 1) sample with graphene flakes grown on its surface. We find that Medipix2 offers a number of advantages over the MCP. The adjustable threshold settings allow Medipix2 to operate as a noiseless detector, offering an improved signal-to-noise ratio for the same amount of signal compared to the MCP. At the same magnification Medipix2 images exhibit superior resolution and can handle significantly higher electron current densities than an MCP, offering the prospect of substantially higher frame rates in LEEM imaging. These factors make Medipix2 an excellent candidate to become the detector of choice for LEEM/PEEM applications.

  16. Design of large-format X-ray framing image tube

    International Nuclear Information System (INIS)

    Zong Fangke; Yang Qinlao; Gu Li; Li Xiang; Zhang Jingjin

    2012-01-01

    An implementation method of large-format framing image tube is proposed. An electrostatic focusing image tube with large input photocathode and small output image is designed. Coupling with common small-format microchannel plate (MCP) gated framing unit, image gating and enhancement can be realized. Compared to the tube with large-format MCP, this kind of framing tube avoids the high manufacturing cost of lager-format MCP and overcomes the transmission voltage loss and gain uniformity caused by long micro strips. The framing image tube has an effective input working diameter of 100 mm, an output image diameter of 40 mm, and a magnification of 0.4. The centre spatial resolution is 14.4 lp/mm, the marginal spatial resolution is 11.2 lp/mm, and the the geometric distortion is less than 15%. The framing characteristics is determined by the MCP framing unit. This method is an effective way for expanding the work area of framing image tubes. (authors)

  17. On the channel box for the fuel bundle of BWR

    International Nuclear Information System (INIS)

    Yokoyama, Hiroomi; Yamamoto, Takeo

    1976-01-01

    Channel boxes play the important roles of making coolant flow uniform and protecting fuel rods as the component of fuel assemblies for BWRs. About ten years ago, the domestic production of channel boxes was first investigated, and now, the original technology has been developed, and the channel boxes sufficiently satisfying the required quality can be produced. The actual experience by being charged in reactors has also been accumulated. At present, the supply capacity is almost sufficient to meet the domestic demand, and the future increase of demand can be dealt with promptly. The channel boxes are made of Zircaloy-4 plates which are favorable in view of neutron absorption, and are the boxes with 138 mm hollow square section, 2 mm thickness, and 4240 mm length. Two channels were welded together and made into a box. In order to eliminate the residual stress caused during the manufacture, high temperature heating with an electric furnace was adopted. The measurement of dimensions and the inspection of appearance of the channel boxes after irradiation proved that they were rather superior to imported ones. The production processes, the system for the quality guarantee, and the quality control in the Kobe Steel Ltd. are explained. The test and inspection are carried out at the time of accepting outside products, before starting the production, after the completion of longitudinal welding and after the completion of production. (Kako, I.)

  18. Experimental study of falling water limitation under counter-current flow in the vertical rectangular channel

    International Nuclear Information System (INIS)

    Usui, Tohru; Kaminaga, Masanori; Sudo, Yukio.

    1988-07-01

    Quantitative understanding of critical heat flux (CHF) in the narrow vertical rectangular channel is required for the thermo-hydroulic design and the safety analysis of research reactors in which flat-plate-type fuel is adopted. Especially, critical heat flux under low downward velocity has a close relation with falling water limitation under counter-current flow. Accordingly, CCFL (Counter-current Flow Limitation) experiments were carried out for both vertical rectangular channels and vertical circular tubes varried in their size and configuration of their cross sections, to make clear CCFL characteristics in the vertical rectangular channels. In the experiments, l/de of the rectangular channel was changed from 3.5 to 180. As the results, it was clear that different equivalent hydraulic diameter de, namely width or water gap of channel, gave different CCFL characteristics of rectangular channel. But the influence of channel length l on CCFL characteristics was not observed. Besides, a dimensionless correlation to estimate a relation between upward air velocity and downward water velocity was proposed based on the present experimental results. The difference of CCFL characteristics between rectangular channels and circular tubes was also investigated. Especially for the rectangular channels, dry-patches appearing condition was made clear as a flow-map. (author)

  19. A numerical investigation of turbulent flow in an 18-plate nuclear fuel assembly

    International Nuclear Information System (INIS)

    Yu, R.; Lightstone, M.F.

    2003-01-01

    A numerical simulation of the fluid flow in the core of the McMaster Nuclear Reactor (MNR) was performed. The standard k - ε turbulence model together with a two-layer wall boundary model was used in the current study. A two-dimensional numerical model for the MNR 18-plate nuclear fuel assembly was developed using the advanced commercial computational fluid dynamics (CFD) code CFX-TASCflow. The numerical predictions were compared with experimental data for the MNR 18-plate assembly at the same flow conditions. In general, the code over predicts the pressure drop for the range of the mass flow rate investigated, however, the difference decreases as the mass flow rate (or Reynolds number) increases. Errors of less than 4% were obtained for mass flows greater than 4.0 kg/s. The comparison shows that the predicted flow distribution and velocities are very close to the measured data for the high Reynolds number flows. It is found that the k - ε model with the two-layer wall boundary model can predict the flow in the vertical parallel plate channels in the low Reynolds number region (Re=3000 to 10,000) very well. (author)

  20. Nanoporous network channels from self-assembled triblock copolymer supramolecules.

    Science.gov (United States)

    du Sart, Gerrit Gobius; Vukovic, Ivana; Vukovic, Zorica; Polushkin, Evgeny; Hiekkataipale, Panu; Ruokolainen, Janne; Loos, Katja; ten Brinke, Gerrit

    2011-02-16

    Supramolecular complexes of a poly(tert-butoxystyrene)-block-polystyrene-block-poly(4-vinylpyridine) triblock copolymers and less than stoichiometric amounts of pentadecylphenol (PDP) are shown to self-assemble into a core-shell gyroid morphology with the core channels formed by the hydrogen-bonded P4VP(PDP)complexes. After structure formation, PDP was removed using a simple washing procedure, resulting in well-ordered nanoporous films that were used as templates for nickel plating. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.