WorldWideScience

Sample records for certified reference materials

  1. Development studies of captopril certified reference material

    Directory of Open Access Journals (Sweden)

    Raquel Nogueira

    2011-06-01

    Full Text Available This paper describes the studies performed with the candidate Certified Reference Material (CRM of captopril, the first CRM of an active pharmaceutical ingredient (API in Brazil, including determination of impurities (organic, inorganic and volatiles, homogeneity testing, short- and long-term stability studies, calculation of captopril content using the mass balance approach, and estimation of the associated measurement uncertainty.Este artigo descreve os estudos realizados com o candidato a Material de Referência Certificado (MRC de captopril, primeiro MRC de fármacos no Brasil, incluindo a determinação de impurezas (orgânicas, inorgânicas e voláteis, testes de homogeneidade, testes de estabilidade de curta e longa duração, cálculo do teor de captopril por balanço de massa e estimativa da incerteza de medição associada ao valor certificado.

  2. Certified reference materials of trace elements in water

    Indian Academy of Sciences (India)

    A K Agrawal

    2005-07-01

    Measurement of trace elements is playing a vital role in industries and various sectors of science and technology including semiconductors, food, health and environmental sectors. In most of the cases a small error in measurement can vitiate all the measures taken for quality control and management. Many decisions regarding the suitability of material/products are based on the analysis. To reduce or eliminate the rejection rate of the products, accurate and reliable measurements are needed which can be achieved by the use of certified reference materials (CRMs). Their use in calibration of analytical equipments and validation of test methods ensures high quality in measurements and it provides traceability to the measurement data with national/international measurement systems (SI unit) also. In the present scenario of globalization of economy, use of certified reference materials (CRMs) in measurements is essential for global acceptance of products and test reports. Their use fulfil a mandatory requirement of international quality systems (ISO 9000, ISO/IEC standard 17025) including our national accreditation body, National Accreditation Board for Testing and Calibration Laboratories (NABL), World Trade Organization (WTO) etc. International manufacturers of CRMs are meeting most of the requirement of CRMs of the country. To meet the demand of CRMs indigenously, the National Physical Laboratory, India initiated a national programme on preparation and dissemination of certified reference materials.

  3. Bias detection and certified reference materials for random measurands

    Science.gov (United States)

    Rukhin, Andrew L.

    2015-12-01

    A problem that frequently occurs in metrology is the bias checking of data obtained by a laboratory against the specified value and uncertainty estimate given in the certificate of analysis. The measurand—a property of a certified reference material (CRM)—is supposed to be random with a normal distribution whose parameters are given by the certificate specifications. The laboratory’s data from subsequent measurements of the CRM (a CRM experiment) are summarized by the sample mean value and its uncertainty which is commonly based on a repeatability standard deviation. New confidence intervals for the lab’s bias are derived. Although they may lack intuitive appeal, those obtained by using higher order asymptotic methods, compared and contrasted in this paper, are recommended.

  4. Certified reference material to water content determination in bioethanol fuel

    Directory of Open Access Journals (Sweden)

    Janaína M. Rodrigues

    2012-01-01

    Full Text Available Bioethanol is a strategic biofuel in Brazil. Thus, a strong metrological basis for its measurements is required to ensure the quality and promote its exportation. Recently, Inmetro certified a reference material for water content in bioethanol. This paper presents the results of these studies. The characterization, homogeneity, short-term stability and long-term stability uncertainty contributions values were 0.00500, 0.0166, 0.0355 and 0.0391 mg g-1, respectively. The certificated value for water content of bioethanol fuel was (3.65 ± 0.11 mg g-1. This CRM is the first and up to now the unique in the world.

  5. Certified reference materials and reference methods for nuclear safeguards and security.

    Science.gov (United States)

    Jakopič, R; Sturm, M; Kraiem, M; Richter, S; Aregbe, Y

    2013-11-01

    Confidence in comparability and reliability of measurement results in nuclear material and environmental sample analysis are established via certified reference materials (CRMs), reference measurements, and inter-laboratory comparisons (ILCs). Increased needs for quality control tools in proliferation resistance, environmental sample analysis, development of measurement capabilities over the years and progress in modern analytical techniques are the main reasons for the development of new reference materials and reference methods for nuclear safeguards and security. The Institute for Reference Materials and Measurements (IRMM) prepares and certifices large quantities of the so-called "large-sized dried" (LSD) spikes for accurate measurement of the uranium and plutonium content in dissolved nuclear fuel solutions by isotope dilution mass spectrometry (IDMS) and also develops particle reference materials applied for the detection of nuclear signatures in environmental samples. IRMM is currently replacing some of its exhausted stocks of CRMs with new ones whose specifications are up-to-date and tailored for the demands of modern analytical techniques. Some of the existing materials will be re-measured to improve the uncertainties associated with their certified values, and to enable laboratories to reduce their combined measurement uncertainty. Safeguards involve the quantitative verification by independent measurements so that no nuclear material is diverted from its intended peaceful use. Safeguards authorities pay particular attention to plutonium and the uranium isotope (235)U, indicating the so-called 'enrichment', in nuclear material and in environmental samples. In addition to the verification of the major ratios, n((235)U)/n((238)U) and n((240)Pu)/n((239)Pu), the minor ratios of the less abundant uranium and plutonium isotopes contain valuable information about the origin and the 'history' of material used for commercial or possibly clandestine purposes, and

  6. Development studies of a new metronidazole certified reference material

    OpenAIRE

    Nogueira, Raquel; Rocha, Werickson Fortunato de Carvalho; Silva,Thaís Elias da; Rego, Eliane Cristina Pires do; Moreira, Gabriela Fernandes; Wollinger, Wagner; Caixeiro, Janaína Marques Rodrigues

    2012-01-01

    Este artigo apresenta os resultados dos estudos realizados com o candidato a material de referência certificado (MRC) de metronidazol, primeiro MRC deste fármaco disponibilizado no mercado e segundo MRC de fármacos brasileiro. Os estudos incluem a determinação dos teores de impurezas orgânicas, inorgânicas e voláteis, validação do método analítico de cromatografia líquida de alta eficiência (CLAE), estudos de estabilidade em condições de transporte e estocagem, estudo de homogeneidade, determ...

  7. Certified reference materials for food packaging specific migration tests: development, validation and modelling

    NARCIS (Netherlands)

    Stoffers, N.H.

    2005-01-01

    Keywords:certified reference materials; diffusion; food contact materials; food packaging; laurolactam; migration modelling; nylon; specific migration This thesis compiles several research topics

  8. A certified reference material for radionuclides in the water sample from Irish Sea (IAEA-443)

    DEFF Research Database (Denmark)

    Pham, M.K.; Betti, M.; Povinec, P.P.

    2011-01-01

    A new certified reference material (CRM) for radionuclides in sea water from the Irish sea (IAEA-443) is described and the results of the certification process are presented. Ten radionuclides (3H, 40K, 90Sr, 137Cs, 234U, 235U, 238U, 238Pu, 239+240Pu and 241Am) have been certified, and informatio...... of radionuclides in water samples, for the development and validation of analytical methods and for training purposes. The material is available in 5 L units from IAEA (http://nucleus.iaea.org/rpst/index.htm)....

  9. Certified Reference Material IAEA-446 for radionuclides in Baltic Sea seaweed

    DEFF Research Database (Denmark)

    Pham, M.K.; Benmansour, M.; Carvalho, F.P.

    2014-01-01

    A Certified Reference Material (CRM) for radionuclides in seaweed (Fucus vesiculosus) from the Baltic Sea (IAEA-446) is described and the results of the certification process are presented. The 40K, 137Cs, 234U and 239þ240Pu radionuclides were certified for this material, and information values...... for 12 other radionuclides (90Sr, 99Tc, 210Pb (210Po), 226Ra, 228Ra, 228Th, 230Th, 232Th, 235U, 238U, 239Pu and 240Pu) are presented. The CRM can be used for Quality Assurance/Quality Control of analysis of radionuclides in seaweed and other biota samples, as well as for development and validation...

  10. Development of a Certified Reference Material (NMIJ CRM 7203-a) for Elemental Analysis of Tap Water.

    Science.gov (United States)

    Zhu, Yanbei; Narukawa, Tomohiro; Inagaki, Kazumi; Miyashita, Shin-Ichi; Kuroiwa, Takayoshi; Ariga, Tomoko; Kudo, Izumi; Koguchi, Masae; Heo, Sung Woo; Suh, Jung Ki; Lee, Kyoung-Seok; Yim, Yong-Hyeon; Lim, Youngran

    2017-01-01

    A certified reference material (CRM), NMIJ CRM 7203-a, was developed for the elemental analysis of tap water. At least two independent analytical methods were applied to characterize the certified value of each element. The elements certified in the present CRM were as follows: Al, As, B, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, Pb, Rb, Sb, Se, Sr, and Zn. The certified value for each element was given as the (property value ± expanded uncertainty), with a coverage factor of 2 for the expanded uncertainty. The expanded uncertainties were estimated while considering the contribution of the analytical methods, the method-to-method variance, the sample homogeneity, the long-term stability, and the concentrations of the standard solutions for calibration. The concentration of Hg (0.39 μg kg(-1)) was given as the information value, since loss of Hg was observed when the sample was stored at room temperature and exposed to light. The certified values of selected elements were confirmed by a co-analysis carried out independently by the NMIJ (Japan) and the KRISS (Korea).

  11. Characterization of brown rice as a certified reference material for Fukushima accident-related radioactivity measurements.

    Science.gov (United States)

    Unno, Yasuhiro; Hachinohe, Mayumi; Hamamatsu, Shioka; Todoriki, Setsuko; Yunoki, Akira; Miura, Tsutomu

    2014-05-01

    We developed a certified reference material of brown rice to measure radioactivity from the Fukushima Daiichi Nuclear Power Plant accident. The rice was planted in the spring of 2011, just after the Fukushima accident occurred, and it was harvested in the autumn of 2011. The certified value of radioactivity concentration in the rice was 33.6 Bq kg(-1) of Cs-134 and 51.8 Bq kg(-1) of Cs-137 on August 1, 2012. The reference material is being widely distributed by the National Metrology Institute of Japan. To determine the radioactivity and its uncertainties in the brown rice, we employed gamma-ray spectrometry with a high-purity germanium detector and Monte Carlo simulation.

  12. Development of a Certified Reference Material for myeloperoxidase-anti-neutrophil cytoplasmic autoantibodies (MPO-ANCA).

    Science.gov (United States)

    Monogioudi, Evanthia; Hutu, Dana Petronela; Martos, Gustavo; Sheldon, Joanna; Schimmel, Heinz; Meroni, Pier Luigi; Zegers, Ingrid

    2016-06-01

    A serum Certified Reference Material (CRM) for supporting reliable autoimmune diagnostics was recently released by the Institute for Reference Materials and Measurements (IRMM) of the Joint Research Centre of the European Commission. It was produced in collaboration with a Working Group on the Harmonisation of Autoimmune Tests of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC WG-HAT). This material is aimed at facilitating the standardisation of measurements of anti-myeloperoxidase immunoglobulin G antibodies. The CRM could be used as a common calibrant by clinicians and manufacturers thereby significantly improving the comparability of results from commercial immunoassays used for IgG anti-MPO measurements. This paper provides information on the new CRM and its intended use.

  13. Certified reference material of bioethanol for metrological traceability in electrochemical parameters analyses.

    Science.gov (United States)

    Serta Fraga, Isabel Cristina; Ribeiro, Carla Matos; Sobral, Sidney Pereira; Dias, Júlio Cesar; Gonçalves, Mary Ane; Borges, Paulo Paschoal; Gonzaga, Fabiano Barbieri

    2012-09-15

    Bioethanol has become an important biofuel because it is a source of renewable energy and can help to decrease global warming. However, the quality of bioethanol needs to be guaranteed so that it can be trusted and accepted in international trade. The Brazilian Metrology Institute (Inmetro) has been developing a certified reference material (CRM) for bioethanol to ensure quality control for measurement in the bioethanol matrix. Inmetro has certified 11 quality parameters. Using these, the CRM of bioethanol will contribute to guaranteeing metrological traceability and reliable measurement results. These factors can be used to compare different bioethanols produced to comply with legislation in different countries in order to avoid technical barriers and thus increase the international trade in Brazilian bioethanol. The aim of this paper is to present the results of certification studies using three important electrochemical quality parameters in the CRM of bioethanol-total acid number, pHe and electrolytic conductivity-which are crucial in protecting the metallic parts of a vehicle from corrosion. The certified results obtained for total acid number, pHe and electrolytic conductivity parameters were (16.2±1.7)mg L(-1), 6.07±0.30, and (1.03±0.11)μS cm(-1), respectively. The uncertainties for all parameters were the expanded uncertainty obtained by multiplying the combined standard uncertainty by a coverage factor of k=2, which represents an approximately 95% confidence level.

  14. Fundamental studies to develop certified reference material to calibrate spectrophotometer in the ultraviolet region

    Science.gov (United States)

    da Conceição, F. C.; Borges, P. P.; Gomes, J. F. S.

    2016-07-01

    Spectrophotometry is the technique used in a great number of laboratories around the world. Quantitative determination of a high number of inorganic, organic and biological species can be made by spectrophotometry using calibrated spectrophotometers. International standards require the use of optical filters to perform the calibration of spectrophotometers. One of the recommended materials is the crystalline potassium dichromate (K2Cr2O7), which is used to prepare solutions in specific concentrations for calibration or verification of spectrophotometers in the ultraviolet (UV) spectral regions. This paper presents the results concerning the fundamental studies for developing a certified reference material (CRM) of crystalline potassium dichromate to be used as standard of spectrophotometers in order to contribute to reliable quantitative analyses.

  15. Development of hemoglobin A1c certified reference material by liquid chromatography isotope dilution mass spectrometry.

    Science.gov (United States)

    Bi, Jiaming; Wu, Liqing; Yang, Bin; Yang, Yi; Wang, Jing

    2012-04-01

    We report the development of a National Institute of Metrology (NIM) hemoglobin A(1c) (HbA(1c)) certified reference material (CRM). Each CRM unit contains about 10 μL of hemoglobin. Both hemoglobin and glycated hemoglobin were quantitatively determined by high-performance liquid chromatography (HPLC)-isotope dilution mass spectrometry (IDMS) with synthesized VHLTPE and glycated VHLTPE as standards. The mass fraction of synthesized VHLTPE or glycated VHLTPE was also quantitatively determined by HPLC-IDMS with NIM amino acid CRMs as standards. The homogeneity and stability of the CRMs were examined with a commercial HbA(1c) analyzer based on the HPLC principle. Fifteen units were randomly selected for homogeneity examination, and statistical analysis showed there was no inhomogeneity. Examination of the stability showed that the CRM was stable for at least 6 months at -80 °C. Uncertainty components of the balance, amino acid purity, hydrolysis and proteolysis efficiency, method reproducibility, homogeneity, and stability were taken into consideration for uncertainty evaluation. The certified value of NIM HbA(1c) CRM was expressed as the ratio of HbA(1c) to total hemoglobin in moles, and was (9.6 ± 1.9)%. The CRM can be used as a calibration or validation standard for clinical diagnostics. It is expected to improve the comparability for HbA(1c) measurement in China.

  16. A new Certified Reference Material for radionuclides in Irish sea sediment (IAEA-385)

    Energy Technology Data Exchange (ETDEWEB)

    Pham, M.K. [Marine Environment Laboratories, International Atomic Energy Agency, MC 98000 Principality of Monaco (Monaco)], E-mail: m.pham@iaea.org; Sanchez-Cabeza, J.A.; Povinec, P.P. [Marine Environment Laboratories, International Atomic Energy Agency, MC 98000 Principality of Monaco (Monaco); Andor, K. [Frederic Joliot-Curie National Research Inst. for Radiobiology and Radiohygiene, Anna u. 5, 1221 Budapest (Hungary); Arnold, D. [Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig (Germany); Benmansour, M. [Centre National de l' Energies des Sciences et des Techniques Nucleaires, 1382 Agdal, Rabat 10001 (Morocco); Bikit, I. [Dept. of Physics, Faculty of Science and Mathematics, University of Novi Sad, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia (Serbia ); Carvalho, F.P. [Instituto Tecnologico e Nuclear, E.N. 10, P-2686-953 Sacavem (Portugal); Dimitrova, K. [Executive Environment Agency of Bulgaria, Regional Laboratory Varna, 4 Jan Palah Str., Varna 9000 (Bulgaria); Edrev, Z.H. [Regional Inspectorate of Environment and Waters, 2 Stara Planina str., 6000 Stara Zagora (Bulgaria); Engeler, C. [Radiochemistry Dept., Institute for Inland Water Management and Waste Water Treatment, P.O. Box 17, 8200 AA Lelystad (Netherlands); Fouche, F.J. [South African Nuclear Energy Corporation NECSA Ltd., P.O. Box 582, Pretoria 0001 (South Africa); Garcia-Orellana, J. [Dept. de Fisica, Universitat Automona de Barcelona, 08193-Cerdanyola del Valles (Spain); Gasco, C. [Instituto de Medio Ambiente, Radioecologia del Medio Acuatico, Av. de la Complutense 22, 28040 Madrid (Spain); Gastaud, J. [Marine Environment Labs., International Atomic Energy Agency, MC 98000 Principality of Monaco (Monaco); Gudelis, A. [Institute of Physics, Nuclear and Environmental Radioactivity Research Lab., Savanoriu Ave 231, 2053 Vilnius (Lithuania); Hancock, G. [CSIRO Land and Water, Clunies Ross St., GPO Box 1666, Canberra, ACT 2601 (Australia)] (and others)

    2008-11-15

    A new Certified Reference Material (CRM) for radionuclides in sediment (IAEA-385) is described and the results of the certification process are presented. Eleven radionuclides ({sup 40}K, {sup 137}Cs, {sup 226}Ra, {sup 228}Ra, {sup 230}Th, {sup 232}Th, {sup 234}U, {sup 238}U, {sup 238}Pu, {sup 239+240}Pu and {sup 241}Am) have been certified and information mass activities with 95% confidence intervals are given for seven other radionuclides ({sup 90}Sr, {sup 210}Pb({sup 210}Po), {sup 235}U, {sup 239}Pu, {sup 240}Pu and {sup 241}Pu). Results for less frequently reported radionuclides ({sup 60}Co, {sup 99}Tc, {sup 134}Cs, {sup 155}Eu, {sup 224}Ra and {sup 239}Np) and information on some activity and mass ratios are also reported. The CRM can be used for quality assurance/quality control of the analysis of radionuclides in sediment samples, for the development and validation of analytical methods and for training purposes.

  17. Development of a new ferulic acid certified reference material for use in clinical chemistry and pharmaceutical analysis

    Directory of Open Access Journals (Sweden)

    Dezhi Yang

    2015-05-01

    Full Text Available This study compares the results of three certified methods, namely differential scanning calorimetry (DSC, the mass balance (MB method and coulometric titrimetry (CT, in the purity assessment of ferulic acid certified reference material (CRM. Purity and expanded uncertainty as determined by the three methods were respectively 99.81%, 0.16%; 99.79%, 0.16%; and 99.81%, 0.26% with, in all cases, a coverage factor (k of 2 (P=95%. The purity results are consistent indicating that the combination of DSC, the MB method and CT provides a confident assessment of the purity of suitable CRMs like ferulic acid.

  18. Development of a certified reference material: ethanol in water - a practical case

    Directory of Open Access Journals (Sweden)

    Vanderléa de Souza

    2006-01-01

    Full Text Available The present work describes the development of a certified reference material (CRM composed of solutions of ethanol in water in five different concentrations, and all stages necessary for the development of an CRM, according to the guidelines of ISO GUIDES 30, 31, 32, 33, 34 and 35. The development of this CRM has been determined by Inmetro Rule n. 006 of 2002, which requires that all breath alcohol analyzers being used in Brazil shall have their respective models approved and that the subsequent verifications shall be performed based on tests with solutions of ethanol in water. As a result, the development of this CRM significantly contributes to the reliability of measurements performed with breath alcohol analyzers, with stated measurement uncertainty. Equally important, this development provides society with a CRM that may have multiple applications, not restricted to the verification of breath alcohol analyzers.O presente trabalho descreve o desenvolvimento de um material de referência certificado (MRC referente a soluções de etanol em água em cinco concentrações diferentes, abordando todas as etapas necessárias para o desenvolvimento de um MRC, conforme prescreve as ISO GUIDE 30, 31, 32, 33, 34 e 35. O desenvolvimento deste MRC originou-se nas determinações da Portaria Inmetro n° 006 de 2002, que assegura que todos os etilômetros a serem utilizados no Brasil deverão ter os seus modelos aprovados, e as verificações realizadas a partir de ensaios com soluções de etanol em água. Após um treinamento, em fevereiro de 2003, no The Federal Institute for Material Research and Testing - BAM, que é um instituto metrológico alemão designado, a Dquim iniciou o processo de desenvolvimento deste MRC, o qual foi concluído em agosto de 2004. No Inmetro desenvolveu-se inicialmente o procedimento de preparo individual, onde as soluções do MRC são preparadas em garrafas de 0,5 L. Atualmente está se estudando, no Inmetro, o

  19. Certified reference material for radionuclides in fish flesh sample IAEA-414 (mixed fish from the Irish Sea and North Sea)

    DEFF Research Database (Denmark)

    Pham, M.K.; Sanchez-Cabeza, J.A.; Povinec, P.P.

    2006-01-01

    ratios are also included. The CRM can be used for quality assurance/quality control of the analysis of radionuclides in fish sample, for the development and validation of analytical methods and for training purposes. The material is available from IAEA, Vienna, in 100 g units. (c) 2006 Elsevier Ltd. All......A certified reference material (CRM) for radionuclides in fish sample IAEA-414 (mixed fish from the Irish Sea and North Seas) is described and the results of the certification process are presented. Nine radionuclides (K-40, Cs-137, Th-232, U-234, U-235, U-238, Pu-238, Pu239+240 and Am-241) were...

  20. Certified reference materials for radionuclides in Bikini Atoll sediment (IAEA-410) and Pacific Ocean sediment (IAEA-412)

    DEFF Research Database (Denmark)

    Pham, M. K.; van Beek, P.; Carvalho, F. P.

    2016-01-01

    The preparation and characterization of certified reference materials (CRMs) for radionuclide content in sediments collected offshore of Bikini Atoll (IAEA-410) and in the open northwest Pacific Ocean (IAEA-412) are described and the results of the certification process are presented. The certified...... radionuclides include: 40K, 210Pb (210Po), 226Ra, 228Ra, 228Th, 232Th, 234U, 238U, 239Pu, 239+240Pu and 241Am for IAEA-410 and 40K, 137Cs, 210Pb (210Po), 226Ra, 228Ra, 228Th, 232Th, 235U, 238U, 239Pu, 240Pu and 239+240Pu for IAEA-412. The CRMs can be used for quality assurance and quality control purposes...

  1. Certified reference materials for testing of the presence/absence of Staphylococcus aureus enterotoxin A (SEA) in cheese.

    Science.gov (United States)

    Zeleny, Reinhard; Nia, Yacine; Schimmel, Heinz; Mutel, Isabelle; Hennekinne, Jacques-Antoine; Emteborg, Håkan; Charoud-Got, Jean; Auvray, Frédéric

    2016-08-01

    Staphylococcal enterotoxins (SEs) account for a substantial number of food-poisoning outbreaks. European legislation (Commission Regulation 1441/2007) stipulates the reference procedure for SE analysis in milk and dairy products, which is based on extraction, dialysis concentration and immunochemical detection using one of two approved assays (VIDAS(®) SET2, Ridascreen(®) SET Total). However, certified reference materials (CRMs) are lacking to support laboratories in performing reliable detection of Staphylococcus aureus enterotoxin A (SEA) in relevant matrices at sub-nanogram per gram levels. The certification of a set of three reference materials (blank and two SEA-containing materials) for testing of the presence/absence of SEA in cheese is described. The reference procedure was applied in an intercomparison with 15 laboratories, and results were reported in a qualitative manner (presence or absence of SEA in the sample). No false-negative or false-positive results were obtained. The certified values were stated as diagnostic specificity (blank material) or diagnostic sensitivity (SEA-containing materials) and were 100 % in all cases. Stability studies demonstrated suitable material stability when stored cooled or frozen. An in-house study on the recovery of SEA in the cheese materials using a double-sandwich enzyme-linked immunosorbent assay (ELISA) revealed comparable recovery values of around 45 % at the two spiking levels and in both the SEA-containing CRMs as well as blank CRM freshly spiked prior to analysis. The values were also comparable over time and among different analysts. The materials provide valuable support to laboratories for method validation and method performance verification and will increase the reliability of measuring SEA in cheese.

  2. A new certified reference material for benzene measurement in air on a sorbent tube: development and proficiency testing.

    Science.gov (United States)

    Caurant, A; Lalère, B; Schbath, M-C; Stumpf, C; Sutour, C; Mace, T; Quisefit, J-P; Doussin, J-F; Vaslin-Reimann, S

    2010-11-01

    A certified matrix reference material (CRM) for the measurement of benzene in ambient air has been developed at Laboratoire National de Métrologie et d'Essais. The production of these CRMs was conducted using a gravimetric method fully traceable to the International System of Units. The CRMs were prepared by sampling an accurate mass of a gaseous primary reference material of benzene, using a high-precision laminar flowmeter and a mass flow controller, with a PerkinElmer sampler filled with Carbopack™ X sorbent. The relative standard deviations obtained for the preparation of a batch of 20 tubes loaded with 500 ng of benzene were below 0.2%. Each CRM is considered independent from the others and with its own certified value and an expanded uncertainty estimated to be within 0.5%, lower than the uncertainties of benzene CRMs already available worldwide. The stability of these materials was also established up to 12 months. These CRMs were implemented during proficiency testing, to evaluate the analytical performances of seven French laboratories involved in benzene air monitoring.

  3. Development of High-purity Certified Reference Materials for 17 Proteinogenic Amino Acids by Traceable Titration Methods.

    Science.gov (United States)

    Kato, Megumi; Yamazaki, Taichi; Kato, Hisashi; Eyama, Sakae; Goto, Mari; Yoshioka, Mariko; Takatsu, Akiko

    2015-01-01

    To ensure the reliability of amino acid analyses, the National Metrology Institute of Japan of the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) has developed high-purity certified reference materials (CRMs) for 17 proteinogenic amino acids. These CRMs are intended for use as primary reference materials to enable the traceable quantification of amino acids. The purity of the present CRMs was determined based on two traceable methods: nonaqueous acidimetric titration and nitrogen determination by the Kjeldahl method. Since neither method could distinguish compounds with similar structures, such as amino acid-related impurities, impurities were thoroughly quantified by combining several HPLC methods, and subtracted from the obtained purity of each method. The property value of each amino acid was calculated as a weighted mean of the corrected purities by the two methods. The uncertainty of the property value was obtained by combining measurement uncertainties of the two methods, a difference between the two methods, the uncertainty from the contribution of impurities, and the uncertainty derived from inhomogeneity. The uncertainty derived from instability was considered to be negligible based on stability monitoring of some CRMs. The certified value of each amino acid, property value with uncertainty, was given for both with or without enantiomeric separation.

  4. Certified reference material for radionuclides in fish flesh sample IAEA-414 (mixed fish from the Irish Sea and North Sea)

    Energy Technology Data Exchange (ETDEWEB)

    Pham, M.K. [International Atomic Energy Agency (IAEA), Marine Environment Laboratory (MEL), MC 98000 (Monaco)]. E-mail: m.pham@iaea.org; Sanchez-Cabeza, J.A.; Povinec, P.P.; Gastaud, J.; La Rosa, J.; Lee, S.-H.; Liong Wee Kwong, L.; Oregioni, B.; Wyse, E. [International Atomic Energy Agency (IAEA), Marine Environment Laboratory (MEL), MC 98000 (Monaco); Arnold, D. [Physikalisch-Technische Bundesanstalt, Braunschweig, 38116 Germany (Germany); Benmansour, M. [Centre National de l' Energie, des Sciences et des Techniques Nucleaires (CNESTEN), B.P. 1382, R.P.10001, Rabat (Morocco); Bojanowski, R. [Institute of Oceanology, Polish Academy of Sciences, PL-81-712 Sopot (Poland); Carvalho, F.P. [Instituto Tecnologico e Nuclear, Departamento de Proteccao Radiologica e Seguranca Nuclear, P-2685-953 Sacavem (Portugal); Kim, C.K. [Department of Radiological Environmental Assessment, Korea Institute of Nuclear Safety, Yo-song, Taejon 305-600, Korea (Korea); Esposito, M. [Laboratorio di Ingegneria Nucleare, Universita di Bologna, 40136 Bologna (Italy); Gasco, C.L. [CIEMAT-DIAE, Radioecologia del Medio Acuatico, 28040 Madrid (Spain); Ham, G.J. [National Radiological Protection Board, Chilton, Didcot, Oxon, OX11 0RA (United Kingdom); Hegde, A.G. [Environmental Survey Laboratory, Bhabha Atomic Research Center, Tarapur Atomic Power Station, Maharashtra 401 504 (India); Holm, E. [Department of Medical Radiation Physics, Lund University Hospital, 22185 Lund (Sweden); Jaskierowicz, D. [Lab. d' Analyses de Surveillance et d' Expertise de la Marine, Base Navale de Cherbourg, 50115 Cherbourg (France); Kanisch, G. [Federal Research Centre for Fisheries, Institute of Fisheries Ecology, 20539 Hamburg (Germany); Llaurado, M. [Lab. de Radiologia Ambiental, Dept. de Quimica Analitica, Facultat de Quimica, Universitat de Barcelona, 08028 Barcelona (Spain); Le Petit, G. [Commissariat a l' Energie Atomique, DASE/SRCE, 91680 Bruyeres-le-Chatel (France); Maruo, Y. [and others

    2006-10-15

    A certified reference material (CRM) for radionuclides in fish sample IAEA-414 (mixed fish from the Irish Sea and North Seas) is described and the results of the certification process are presented. Nine radionuclides ({sup 4}K, {sup 137}Cs, {sup 232}Th, {sup 234}U, {sup 235}U, {sup 238}U, {sup 238}Pu, {sup 239+24}Pu and {sup 241}Am) were certified for this material. Information on massic activities with 95% confidence intervals is given for six other radionuclides ({sup 9}Sr, {sup 21}Pb({sup 21}Po), {sup 226}Ra, {sup 239}Pu, {sup 24}Pu {sup 241}Pu). Less frequently reported radionuclides ({sup 99}Tc, {sup 129}I, {sup 228}Th, {sup 23}Th and {sup 237}Np) and information on some activity and mass ratios are also included. The CRM can be used for quality assurance/quality control of the analysis of radionuclides in fish sample, for the development and validation of analytical methods and for training purposes. The material is available from IAEA, Vienna, in 100 g units.

  5. Development of a certified reference material (NMIJ CRM 7512-a) for the determination of trace elements in milk powder.

    Science.gov (United States)

    Zhu, Yanbei; Narukawa, Tomohiro; Miyashita, Shin-ichi; Kuroiwa, Takayoshi; Inagaki, Kazumi; Chiba, Koichi; Hioki, Akiharu

    2013-01-01

    A certified reference material (CRM), NMIJ CRM 7512-a, was developed for the determination of trace elements in milk powder. At least three independent analytical methods were applied to characterize the certified value of each element; all of these analytical methods were based on microwave acid digestions and carried out using different analytical instruments. The certified value was given on a dry-mass basis, where the dry-mass correction factor was obtained by drying the sample at 65°C for 15 to 25 h. The certified values in the units of mass fractions for 13 elements were as follows: Ca, 8.65 (0.38) g kg(-1); Fe, 0.104 (0.007) g kg(-1); K, 8.41 (0.33) g kg(-1); Mg, 0.819 (0.024) g kg(-1); Na, 1.87 (0.09) g kg(-1); P, 5.62 (0.23) g kg(-1); Ba, 0.449 (0.013) mg kg(-1); Cu, 4.66 (0.23) mg kg(-1); Mn, 0.931 (0.032) mg kg(-1); Mo, 0.223 (0.012) mg kg(-1); Rb, 8.93 (0.31) mg kg(-1); Sr, 5.88 (0.20) mg kg(-1); and Zn, 41.3 (1.4) mg kg(-1), where the numbers in the parentheses are the expanded uncertainties with a coverage factor of 2. The expanded uncertainties were estimated considering the contribution of the analytical methods, the method-to-method variance, the sample homogeneity, the dry-mass correction factor, and the concentrations of the standard solutions for calibration. The concentrations of As (2.1 μg kg(-1)), Cd (0.2 μg kg(-1)), Cr (1.3 μg kg(-1)), Pb (0.3 μg kg(-1)), and Y (64 μg kg(-1)) were given as information values for the present CRM.

  6. Determination of non-certified levoglucosan, sugar polyols and ergosterol in NIST Standard Reference Material 1649a

    Science.gov (United States)

    Pomata, Donatella; Di Filippo, Patrizia; Riccardi, Carmela; Buiarelli, Francesca; Gallo, Valentina

    2014-02-01

    Organic component of airborne particulate matter originates from both natural and anthropogenic sources whose contributions can be identified through the analysis of chemical markers. The validation of analytical methods for analysis of compounds used as chemical markers is of great importance especially if they must be determined in rather complex matrices. Currently, standard reference materials (SRM) with certified values for all those analytes are not available. In this paper, we report a method for the simultaneous determination of levoglucosan and xylitol as tracers for biomass burning emissions, and arabitol, mannitol and ergosterol as biomarkers for airborne fungi in SRM 1649a, by GC/MS. Their quantitative analysis in SRM 1649a was carried out using both internal standard calibration curves and standard addition method. A matrix effect was observed for all analytes, minor for levoglucosan and major for polyols and ergosterol. The results related to levoglucosan around 160 μg g-1 agreed with those reported by other authors, while no comparison was possible for xylitol (120 μg g-1), arabitol (15 μg g-1), mannitol (18 μg g-1), and ergosterol (0.5 μg g-1). The analytical method used for SRM 1649a was also applied to PM10 samples collected in Rome during four seasonal sampling campaigns. The ratios between annual analyte concentrations in PM10 samples and in SRM 1649a were of the same order of magnitude although particulate matter samples analyzed were collected in two different sites and periods.

  7. Development of a certified reference material (NMIJ CRM 7505-a) for the determination of trace elements in tea leaves.

    Science.gov (United States)

    Zhu, Yanbei; Narukawa, Tomohiro; Inagaki, Kazumi; Kuroiwa, Takayoshi; Chiba, Koichi

    2011-01-01

    A certified reference material (CRM) for trace elements in tea leaves has been developed in National Metrology Institute of Japan (NMIJ). The CRM was provided as a dry powder (<90 µm) after frozen pulverization of washed and dried fresh tea leaves from a tea plant farm in Shizuoka Prefecture, Japan. Characterization of the property value for each element was carried out exclusively by NMIJ with at least two independent analytical methods, including inductively coupled plasma mass spectrometry (ICP-MS), high-resolution (HR-) ICP-MS, isotope-dilution (ID-) ICP-MS, inductively coupled plasma optical emission spectrometry (ICP-OES), graphite-furnace atomic-absorption spectrometry (GF-AAS) and flame atomic-absorption spectrometry (FAAS). Property values were provided for 19 elements (Ca, K, Mg, P, Al, B, Ba, Cd, Cu, Fe, Li, Mn, Na, Ni, Pb, Rb, Sr, Zn and Co) and informative values for 18 elements (Ti, V, Cr, Y, and all of the lanthanides, except for Pm whose isotopes are exclusively radioactive). The concentration ranges of property values and informative values were from 1.59% (mass) of K to 0.0139 mg kg(-1) of Cd and from 0.6 mg kg(-1) of Ti to 0.0014 mg kg(-1) of Lu, respectively. Combined relatively standard uncertainties of the property values were estimated by considering the uncertainties of the homogeneity, analytical methods, characterization, calibration standard, and dry-mass correction factor. The range of the relative combined standard uncertainties was from 1.5% of Mg and K to 4.1% of Cd.

  8. Certified reference material for quantification of polycyclic aromatic hydrocarbons and toxic elements in tunnel dust (NMIJ CRM 7308-a) from the National Metrology Institute of Japan

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Nobuyasu; Inagaki, Kazumi; Narukawa, Tomohiro; Aoyagi, Yoshie; Narushima, Izumi; Koguchi, Masae; Numata, Masahiko [National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki (Japan)

    2011-11-15

    The National Metrology Institute of Japan has issued a certified reference material of tunnel dust for polycyclic aromatic hydrocarbons (PAHs) and toxic element analyses. PAH certification was performed using isotope dilution mass spectrometry with deuterium-labeled PAHs as internal standards. Three extraction techniques (microwave-assisted extraction with toluene/methanol, Soxhlet extraction with toluene, and pressurized liquid extraction with toluene) were used, and the extracts were measured by gas chromatography/mass spectrometry with two different columns. For values of PAHs, 11 PAHs are provided as certified values between 0.294 and 20.3 mg/kg, and five PAHs are provided as information values. Certified values of five toxic elements (Cr, Ni, Pb, Mn, and Cd) obtained from microwave-assisted digestions and a combination of measurement techniques are also provided between 43.4 and 10.71 x 10{sup 3} mg/kg. (orig.)

  9. Development of SI-traceable C-peptide certified reference material NMIJ CRM 6901-a using isotope-dilution mass spectrometry-based amino acid analyses.

    Science.gov (United States)

    Kinumi, Tomoya; Goto, Mari; Eyama, Sakae; Kato, Megumi; Kasama, Takeshi; Takatsu, Akiko

    2012-07-01

    A certified reference material (CRM) is a higher-order calibration material used to enable a traceable analysis. This paper describes the development of a C-peptide CRM (NMIJ CRM 6901-a) by the National Metrology Institute of Japan using two independent methods for amino acid analysis based on isotope-dilution mass spectrometry. C-peptide is a 31-mer peptide that is utilized for the evaluation of β-cell function in the pancreas in clinical testing. This CRM is a lyophilized synthetic peptide having the human C-peptide sequence, and contains deamidated and pyroglutamylated forms of C-peptide. By adding water (1.00 ± 0.01) g into the vial containing the CRM, the C-peptide solution in 10 mM phosphate buffer saline (pH 6.6) is reconstituted. We assigned two certified values that represent the concentrations of total C-peptide (mixture of C-peptide, deamidated C-peptide, and pyroglutamylated C-peptide) and C-peptide. The certified concentration of total C-peptide was determined by two amino acid analyses using pre-column derivatization liquid chromatography-mass spectrometry and hydrophilic chromatography-mass spectrometry following acid hydrolysis. The certified concentration of C-peptide was determined by multiplying the concentration of total C-peptide by the ratio of the relative area of C-peptide to that of the total C-peptide measured by liquid chromatography. The certified value of C-peptide (80.7 ± 5.0) mg/L represents the concentration of the specific entity of C-peptide; on the other hand, the certified value of total C-peptide, (81.7 ± 5.1) mg/L can be used for analyses that does not differentiate deamidated and pyroglutamylated C-peptide from C-peptide itself, such as amino acid analyses and immunochemical assays.

  10. The Development of Certified Substantial Reference Material for Radioactivity of Building Materials%放射性建材实物标准样品的研制

    Institute of Scientific and Technical Information of China (English)

    韩颖

    2012-01-01

    Certified Substantial RMs "Reference Material for Radioactivity of Stone", "Reference Material for Radioactivity of the Ceramic Products" and "Reference Material for Radioactivity of the Powder Ash Air- entrained Concrete" are used to calibrate γ spectrometers and examine the veracity of the measurement for the content of radionuclides 256Ra, 232Th and 40K in approximate host-material samples.They covers all the radionuclides needed to be tested in building materials. All the radionuclides have been in secular radioactive equilibrium.The fixed value of these three RMs were measured by 8 authoritative radioactivity testing institution. Their homogeneity and stability is good so as to provide to protection for people's safety and health.%有证实物标准样品“石材放射性标准样品”、“陶瓷产品的放射性标准样品”及“粉煤灰砌块的放射性标准样品”适用于γ谱仪校准和考核相近基质样品中所含放射性核素36Ra、232h和40K含量测定的准确性,覆盖了建材产品需要检验的所有核素,达到放射平衡。样品由8家权威放射性检测机构采用低本底多道γ能谱仪测量方法进行定值测量,均匀性和稳定性良好,以对人们的安全与健康提供保护。

  11. Electrothermal atomic absorption spectrometric determination of vanadium in extracts of soil and sewage sludge certified reference materials after fractionation by means of the Communities Bureau of Reference modified sequential extraction procedure

    Science.gov (United States)

    Žemberyová, M.; Jankovič, R.; Hagarová, I.; Kuss, H.-M.

    2007-05-01

    A modified three-step sequential extraction procedure proposed by the Commission of European Communities Bureau of Reference (BCR) was applied to certified reference materials of three different soil groups (rendzina, luvisol, cambisol) and sewage sludge of different composition originating from a municipal water treatment plant in order to assess potential mobility and the distribution of vanadium in the resulting fractions. Analysis of the extracts was carried out by electrothermal atomic absorption spectrometry with Zeeman background correction using transversely heated graphite atomizers. Extracts showed significant matrix interferences which were overcome by the standard addition technique. The original soil and sludge certified reference materials (CRMs) and the extraction residue from the sequential extraction were decomposed by a mixture of HNO 3-HClO 4-HF in an open system. The content of V determined after decomposition of the samples was in very good agreement with the certified total values. The accuracy of the sequential extraction procedure was checked by comparing the sum of the vanadium contents in the three fractions and in the extraction residue with the certified total content of V. The amounts of vanadium leached were in good correlation with the certified total contents of V in the CRMs of soils and sewage sludge. In the soils examined, vanadium was present almost entirely in the mineral lattice, while in the sewage sludge samples 9-14% was found in the oxidizable and almost 25% in the reducible fractions. The recovery ranged from 93-106% and the precision (RSD) was below 10%.

  12. Determination of the carbon, hydrogen and nitrogen contents of alanine and their uncertainties using the certified reference material L-alanine (NMIJ CRM 6011-a).

    Science.gov (United States)

    Itoh, Nobuyasu; Sato, Ayako; Yamazaki, Taichi; Numata, Masahiko; Takatsu, Akiko

    2013-01-01

    The carbon, hydrogen, and nitrogen (CHN) contents of alanine and their uncertainties were estimated using a CHN analyzer and the certified reference material (CRM) L-alanine. The CHN contents and their uncertainties, as measured using the single-point calibration method, were 40.36 ± 0.20% for C, 7.86 ± 0.13% for H, and 15.66 ± 0.09% for N; the results obtained using the bracket calibration method were also comparable. The method described in this study is reasonable, convenient, and meets the general requirement of having uncertainties ≤ 0.4%.

  13. Thermal desorption GC-MS as a tool to provide PAH certified standard reference material on particulate matter quartz filters.

    Science.gov (United States)

    Grandesso, Emanuela; Pérez Ballesta, Pascual; Kowalewski, Konrad

    2013-02-15

    Reference materials for particulate matter (PM) on filter media are not available for the quantification of polycyclic aromatic hydrocarbons (PAHs) in ambient air. This is due to the difficulty of obtaining reference material that has a homogeneous distribution on a filter surface that is large enough for characterization and distribution. High volume sample filters from different locations and seasons were considered to validate the feasibility of the use of quartz filters as reference material for PAH concentrations. A rapid thermal desorption (TD) technique coupled with gas chromatography/mass spectroscopy was applied to characterise the material for the content of fifteen different PAHs. TD technique allowed for rapid and accurate analysis of small sections of filter (5mm diameter), leaving enough material for the production of twenty sub-filter cuts (42 mm diameter) that could be used for distribution and control. Stability and homogeneity tests required for material certification were performed as indicated by the ISO guide 34:2009 and ISO 35:2006. The contribution of the heterogeneous distribution of PAHs on the filter surface resulted generally lower than 10% and higher for more volatile PAHs. One year of storage at -18°C indicated no significant variation in PAH concentrations. Nevertheless, a methodology for shipping and storing of the filter material at ambient temperature in especially designed plastic envelopes, was also shown to allow for stabile concentrations within twenty days. The method accuracy was confirmed by the analysis of NIST SRM 1649a (urban dust) and PAH concentrations were validated against the reference values obtained from an inter-laboratory exercise. In the case of benzo[a]pyrene for masses quantified between 100 pg and 10 ng the TD method provided expanded uncertainties of circa 10%, while the inter-laboratory reference value uncertainties ranged between 15 and 20%. The evaluation of these results supports the use of the presented

  14. Development of C-reactive protein certified reference material NMIJ CRM 6201-b: optimization of a hydrolysis process to improve the accuracy of amino acid analysis.

    Science.gov (United States)

    Kato, Megumi; Kinumi, Tomoya; Yoshioka, Mariko; Goto, Mari; Fujii, Shin-Ichiro; Takatsu, Akiko

    2015-04-01

    To standardize C-reactive protein (CRP) assays, the National Metrology Institute of Japan (NMIJ) has developed a C-reactive protein solution certified reference material, CRM 6201-b, which is intended for use as a primary reference material to enable the SI-traceable measurement of CRP. This study describes the development process of CRM 6201-b. As a candidate material of the CRM, recombinant human CRP solution was selected because of its higher purity and homogeneity than the purified material from human serum. Gel filtration chromatography was used to examine the homogeneity and stability of the present CRM. The total protein concentration of CRP in the present CRM was determined by amino acid analysis coupled to isotope-dilution mass spectrometry (IDMS-AAA). To improve the accuracy of IDMS-AAA, we optimized the hydrolysis process by examining the effect of parameters such as the volume of protein samples taken for hydrolysis, the procedure of sample preparation prior to the hydrolysis, hydrolysis temperature, and hydrolysis time. Under optimized conditions, we conducted two independent approaches in which the following independent hydrolysis and liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) were combined: one was vapor-phase acid hydrolysis (130 °C, 24 h) and hydrophilic interaction liquid chromatography-mass spectrometry (HILIC-MS) method, and the other was microwave-assisted liquid-phase acid hydrolysis (150 °C, 3 h) and pre-column derivatization liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. The quantitative values of the two different amino acid analyses were in agreement within their uncertainties. The certified value was the weighted mean of the results of the two methods. Uncertainties from the value-assignment method, between-method variance, homogeneity, long-term stability, and short-term stability were taken into account in evaluating the uncertainty for a certified value. The certified value and the

  15. Effect of certified reference material 470 (CRM 470) on national quality assurance programs for serum proteins in Europe.

    Science.gov (United States)

    Johnson, A M; Whicher, J T

    2001-11-01

    The introduction of the international reference material for serum proteins, CRM 470, has resulted in significant reduction of the among-laboratory variance for most proteins assayed in European national quality assurance programs. In general, the CVs have decreased by 5 to 65%. However, both among- and within-manufacturer variances in many cases remain unacceptably high. In addition, concentration-dependent differences in variance and bias are present for some proteins. Although some variance will persist, reducing variance and bias to levels required for the institution of universal reference ranges will necessitate more accurate transfer of values to calibrants and controls and improved calibration curve fitting by manufacturers, as well as better quality control within laboratories.

  16. Determination of metal concentrations in certified plastic reference materials after small-size autoclave and microwave-assisted digestion followed with inductively coupled plasma optical emission spectrometry

    Science.gov (United States)

    Lehtimäki, Esa; Väisänen, Ari

    2017-01-01

    The digestion methods for the determination of As, Cd, Cr, Pb, Sb, Sn and Zn concentrations in plastic samples using microwave-assisted digestion (MW-AD) and small-size autoclave digestion was developed. The certified polyethylene, polypropylene, polyvinyl chloride and acrylonitrile butadiene styrene certified reference materials were used in order to find digestion method working properly for several sample matrices. Efficiency of the digestion methods was evaluated by analyzing the residual carbon in digests by TOC analyzer. MW-AD using a mixture of 7 mL of HNO3 and 3 mL of H2O2 as a digestion solution resulted in excellent recoveries for As, Cd, Pb, Sb and Zn, and were in the range of 92-107% for all the analytes except Pb in polyethylene material. Autoclave digestion using 5 mL of concentrated HNO3 as a digestion solution resulted in similar recoveries with the exception of a higher As recovery (98%). Tin recovery resulted in low level after both MW-AD and autoclave digestion. Autoclave digestion was further developed resulting in a partially open two-step digestion process especially for the determination of Sn and Cr. The method resulted in higher recoveries of Sn and Cr (87 and 76%) but with the lower concentration of easily volatile As, Cd and Sb.

  17. Quantitative Analysis of Plutonium Content in Particles Collected from a Certified Reference Material by Total Nuclear Reaction Energy (Q Value) Spectroscopy

    Science.gov (United States)

    Croce, M. P.; Hoover, A. S.; Rabin, M. W.; Bond, E. M.; Wolfsberg, L. E.; Schmidt, D. R.; Ullom, J. N.

    2016-08-01

    Microcalorimeters with embedded radioisotopes are an emerging category of sensor with advantages over existing methods for isotopic analysis of trace-level nuclear materials. For each nuclear decay, the energy of all decay products captured by the absorber (alpha particles, gamma rays, X-rays, electrons, daughter nuclei, etc.) is measured in one pulse. For alpha-decaying isotopes, this gives a measurement of the total nuclear reaction energy (Q value) and the spectra consist of well-separated, narrow peaks. We have demonstrated a simple mechanical alloying process to create an absorber structure consisting of a gold matrix with small inclusions of a radioactive sample. This absorber structure provides an optimized energy thermalization environment, resulting in high-resolution spectra with minimal tailing. We have applied this process to the analysis of particles collected from the surface of a plutonium metal certified reference material (CRM-126A from New Brunswick Laboratory) and demonstrated isotopic analysis by microcalorimeter Q value spectroscopy. Energy resolution from the Gaussian component of a Bortels function fit was 1.3 keV FWHM at 5244 keV. The collected particles were integrated directly into the detector absorber without any chemical processing. The ^{238}Pu/^{239}Pu and ^{240}Pu/^{239}Pu mass ratios were measured and the results confirmed against the certificate of analysis for the reference material. We also demonstrated inter-element analysis capability by measuring the ^{241}Am/^{239}Pu mass ratio.

  18. Certification of Charpy V-Notch Reference Test Pieces of 30 J Nominal Absorbed Energy - Certified Reference Materials ERM®-FA013bg and ERM®-FA013bh

    OpenAIRE

    LAMBERTY MARIE ANDREE; Dean, Alan; Roebben, Gert

    2011-01-01

    This certification report describes the processing and characterisation of ERM®-FA013bg and ERM®-FA013bh, two batches of Charpy V-notch certified reference test pieces. Sets of five of these test pieces are used for the verification of pendulum impact test machines according to EN 10045-2 (Charpy impact test on metallic materials, Part 2. Method for the verification of impact testing machines [1]) or according to ISO 148-2 (Metallic materials - Charpy pendulum impact test - Part 2: Verificati...

  19. The Kjeldahl method as a primary reference procedure for total protein in certified reference materials used in clinical chemistry. I. A review of Kjeldahl methods adopted by laboratory medicine.

    Science.gov (United States)

    Chromý, Vratislav; Vinklárková, Bára; Šprongl, Luděk; Bittová, Miroslava

    2015-01-01

    We found previously that albumin-calibrated total protein in certified reference materials causes unacceptable positive bias in analysis of human sera. The simplest way to cure this defect is the use of human-based serum/plasma standards calibrated by the Kjeldahl method. Such standards, commutative with serum samples, will compensate for bias caused by lipids and bilirubin in most human sera. To find a suitable primary reference procedure for total protein in reference materials, we reviewed Kjeldahl methods adopted by laboratory medicine. We found two methods recommended for total protein in human samples: an indirect analysis based on total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. The methods found will be assessed in a subsequent article.

  20. DISCUSSION ON PERIOD VERIFICATION OF MARINE CERTIFIED REFERENCE MATERIAL IN LABORATORY%浅谈实验室如何进行海洋标准物质期间核查

    Institute of Scientific and Technical Information of China (English)

    吴碧玉; 谷尚莉

    2011-01-01

    The classification of marine certified reference material was introuduced. The method for period verification of marine certified reference material to ensure the accuracy of value in marine environmental monitoring and improve the quality of marine monitoring was expounded.%介绍海洋标准物质的分类,阐述了各种海洋标准物质的期间核查方法,以保证海洋环境监测工作量值的准确性,提高海洋监测的质量.

  1. Development of a Certified Reference Material for Lyophilized Vitamin K 1%维生素 K1冻干标准物质的研制

    Institute of Scientific and Technical Information of China (English)

    张晓光; 黄挺; 张伟; 黄亮; 全灿; 李红梅; 杨屹

    2015-01-01

    采用二甲基亚砜(DMSO)作为冻干标准物质的溶剂,以重量法准确配制维生素 K1/ DMSO 溶液,再进行分装、冷冻干燥,经定性分析、定值分析、均匀性检验、稳定性考察和不确定度评定,研制了维生素 K1冻干标准物质。以维生素 K1纯度标准物质溶液为校准品,对得到的冻干物质进行了高效液相色谱法定值分析,冻干标准物质的准确定值结果为0.96 mg/ mL,相对扩展不确定度为7%。建立的维生素 K1冻干标准物质研制方法,对于临床检验中维生素 K1的准确测定和相关疾病的正确诊断治疗以及维生素 K1长期保存具有重要意义。%Dimethyl sulfone( DMSO)is firstly applied as the solvent for a lyophilized certified reference material (CRM). Vitamin K1 / DMSO solution is prepared by gravimetry,and is sub-divided and lyophilized,the lyophilized vitamin K1 CRM is developed through qualitative analysis,quantitative analysis,homogeneity study,stability study and uncertainty evaluation. Certified value of lyophilization vitamin K1 is analyzed by high performance liquid chromatography method, using the vitamin K1 purity CRM as a calibrant. The certified value is 0. 96 mg/ mL,with the relative expanded uncertainty of 7% . The method of CRM lyophilized vitamin K1 makes great significance for the accurate determination the disease in clinical examination and the long-term preservation of vitamin K1 .

  2. Characterization and Uncertainty Assessment of a Certified Reference Material of Chloramphenicol in Methanol (GBW(E)082557)

    Science.gov (United States)

    Zhou, Jian; Song, Yinqing; Wang, Tongtong

    2016-01-01

    Prior to preparation of CRM candidate of chloramphenicol in methanol with a concentration of 100 mg/L, two independent methods including mass balance (MB) and quantitative nuclear magnetic resonance (qNMR) were employed to precisely measure the mass fraction of pure chloramphenicol materials. The mass fraction was assigned to be 99.8% with uncertainty of 0.3%. Homogeneity testing and stability study of chloramphenicol in methanol were examined by using high performance liquid chromatography. Additionally, the uncertainties originating from the process of CRM development were comprehensively evaluated. The experimental results indicate that the property value of this CRM is homogeneous and stable at 4°C for at least six months. The new CRM (GBW(E)082557) can be applicable to calibration of instrument and assurance of accuracy and comparability of results in routine measurement. PMID:27493666

  3. Characterization and Uncertainty Assessment of a Certified Reference Material of Chloramphenicol in Methanol (GBW(E)082557).

    Science.gov (United States)

    Yang, Mengrui; Wang, Min; Zhou, Jian; Song, Yinqing; Wang, Tongtong

    2016-01-01

    Prior to preparation of CRM candidate of chloramphenicol in methanol with a concentration of 100 mg/L, two independent methods including mass balance (MB) and quantitative nuclear magnetic resonance (qNMR) were employed to precisely measure the mass fraction of pure chloramphenicol materials. The mass fraction was assigned to be 99.8% with uncertainty of 0.3%. Homogeneity testing and stability study of chloramphenicol in methanol were examined by using high performance liquid chromatography. Additionally, the uncertainties originating from the process of CRM development were comprehensively evaluated. The experimental results indicate that the property value of this CRM is homogeneous and stable at 4°C for at least six months. The new CRM (GBW(E)082557) can be applicable to calibration of instrument and assurance of accuracy and comparability of results in routine measurement.

  4. Development of a certified reference material (NMIJ CRM 7531-a) for the determination of trace cadmium and other elements in brown rice flour.

    Science.gov (United States)

    Miyashita, Shin-ichi; Inagaki, Kazumi; Narukawa, Tomohiro; Zhu, Yanbei; Kuroiwa, Takayoshi; Hioki, Akiharu; Chiba, Koichi

    2012-01-01

    A certified reference material (CRM) for trace cadmium and other elements in brown rice flour was developed at the National Metrology Institute of Japan (NMIJ). The CRM was provided as a dry powder after drying and frozen pulverization of fresh brown rice obtained from a Japanese domestic market. Characterization of the property value for each element was carried out exclusively by NMIJ with at least two independent analytical methods, including inductively coupled plasma mass spectrometry (ICP-MS), ICP high-resolution mass spectrometry, isotope-dilution ICP-MS, ICP optical emission spectrometry, and graphite-furnace atomic-absorption spectrometry. Property values were provided for six elements (Mn, Fe, Cu, Zn, As, and Cd). The concentration range of the property values was from 0.280 mg kg(-1) of As to 31.8 mg kg(-1) of Zn. The combined relative standard uncertainties of the property values were estimated by considering the uncertainties of the homogeneity, characterization, difference among analytical methods, dry-mass correction factor, and calibration standard. The range of the relative combined standard uncertainties was from 1.1% of Zn to 1.6% of As.

  5. A certified urea reference material (NMIJ CRM 6006-a) as a reliable calibrant for the elemental analyses of amino acids and food samples.

    Science.gov (United States)

    Itoh, Nobuyasu; Yamazaki, Taichi; Sato, Ayako; Numata, Masahiko; Takatsu, Akiko

    2014-01-01

    We examined the reliability of a certified reference material (CRM) for urea (NMIJ CRM 6006-a) as a calibrant for N, C, and H in elemental analyzers. Only the N content for this CRM is provided as an indicative value. To estimate the C and H contents of the urea CRM, we took into account the purity of the urea and the presence of other identified impurities. When we examined the use of various masses of the calibrant (0.2 to 2 mg), we unexpectedly observed low signal intensities for small masses of H and N, but these plateaued at about 2 mg. We therefore analyzed four amino acid CRMs and four food CRMs on a 2-mg scale with the urea CRM as the calibrant. For the amino acid CRMs, the differences in the analytical and theoretical contents (≤0.0026 kg/kg) were acceptable with good repeatability (≤0.0013 kg/kg in standard deviation; n = 4). For food CRMs, comparable repeatabilities to those obtained with amino acid CRMs (≤0.0025 kg/kg in standard deviation; n = 4) were obtained. The urea CRM can therefore be used as a reliable calibrant for C, H, and N in an elemental analyzer.

  6. Development and Certification of Theophylline Certified Reference Material%茶碱标准物质的研制与定值

    Institute of Scientific and Technical Information of China (English)

    马康; 赵敏; 王海峰; 邢金京; 黄挺

    2011-01-01

    A methodology regarding preparation and certification of certified reference material (CRM) of theophylline was presented. The CRM was prepared by repeated recrystallization and drying at 80 ℃ in vacuum condition for 5 h. According to analysis procedure of homogeneity, 11 bottles of sample were randomly taken from 500 bottles, in which one bottle was measured for ten times,the other ten bottles were respectively measured for one time, and the results were validated by F-test and T-test statistical methods. The stability inspection was carried on the short-term( one month) and the long-term( 12 months), and the results indicated that the period for theophylline of storage was 12 months at 20 ℃. The purity of theophylline were determined by two methods e.g. mass balance method and differential scanning calorimetry(DSC) method, based on different principles. The qualitative and quantitative analysis of impurities were respectively performed by liquid chromatography ion trap-time of flight mass spectrometry( LC -IT TOF) and high performance liquid chromatography with diode array detector(DAD). The content of water in theophylline was measured by Karl - Fischer titrator with drying oven using methanol as solvent. Volatile material in theophylline was determined by temperature gravity analysis(TGA). The determination of losses on drying ash was carried out by the routine method. The uncertainty of mass balance method and DSC methods were respectively evaluated. The result showed that the certified result was 99.80% and expanded uncertainty was 0. 14%(k =2).%建立了茶碱标准物质的制备和定值方法.将市售茶碱原料纯化、干燥、混匀后.分装成500瓶样品.随机抽取其中11瓶做均匀性检验.经F检验和T检验.结果表明在95%置信范围内样品的均匀性良好;稳定性检验按短期稳定性(1月)和长期稳定性(12月)分别进行,长期稳定性结果通过了T检验,表明在20℃条件下茶碱的稳定期不少于12

  7. 冻干人尿中汞成分分析标准物质的研制%Development of the certified reference material of mercury in lyophilized human urine

    Institute of Scientific and Technical Information of China (English)

    赵玮; 张福钢; 李春伶; 杜会芳; 潘亚娟; 张敬; 闫慧芳

    2011-01-01

    Objective To develop the certified reference material of mercury in lyophilized human urine. Methods Human urine samples from normal level mercury districts were filtered, homogenized,dispensed, lyophilized and radio-sterilized. Homogeneity test, stability inspection and certification were conducted using a atom fluorescence spectrophotometric method. The physical and chemical stability of the certified reference material were assessed for 18 months. The certified values are based on analysis made by three independent laboratories. Results The certified values are as follows: low level was (35.6±2.1)μg/L,high level was (50.5±3.0) μg/l. Conclusion The certified reference material of mercury in lyophilized human urine in this research reached the national certified reference material requirements and could be used for the quality control.%目的 研制冻干人尿中汞成分分析标准物质.方法 冻干尿由正常人尿经过滤、加标、混匀、分装、冷冻干燥、辐射灭菌制备而成,使用原子荧光测定方法 对其均匀性和稳定性进行检验,由3家实验室用准确可靠的方法 确定标准值,并对尿中汞研制物的不确定度进行分析.结果 本研制物均匀性良好,-20 ℃保存可稳定18个月,2个水平的量值及不确定度分别为(35.6±2.1)和(50.5±3.0)μg/L.结论 尿中汞成分分析标准物质各项指标符合的要求,可用于实验室检测的质量控制.

  8. Certified reference material for the quality control of EDTA- and DTPA-extractable trace metal contents in calcareous soil (CRM 600)

    Energy Technology Data Exchange (ETDEWEB)

    Quevauviller, P. [European Commission, Standards, Measurements and Testing Programme, Brussels (Belgium); Lachica, M.; Barahona, E. [Estacion Experimental del Zaidin, Granada (Spain); Gomez, A. [Institut Nacional de Recherche Agronomique, Station d`Agronomie, Villenave d`Ornon (France); Rauret, G. [Universidad de Barcelona, Dept. de Quimica Analitica, Barcelona (Spain); Ure, A. [University of Strathclyde, Dept. of Pure and Applied Chemistry, Glasgow (United Kingdom); Muntau, H. [European Commission, Joint Research Centre, Environment Institute, Ispra (Italy)

    1998-03-01

    Single extraction tests are commonly used to study the eco-toxicity and mobility of metals in soils, e.g. to assess the bioavailable metal fraction (and thus to estimate the related phyto-toxic and nutritional deficiency effects) and the environmentally accessible trace metals upon disposal of e.g. sediment on to a soil (e.g. contamination of ground waters). However, the lack of uniformity in the different procedures does not allow the results to be compared worldwide nor the procedures to be validated. This paper describes the interlaboratory testing of EDTA- and DTPA-extraction procedures for soil analysis, followed by the preparation of a calcareous soil reference material (CRM 600), the homogeneity and stability studies and the analytical work performed for the certification of the EDTA- and DTPA- extractable contents of some trace metals (following the standardized extraction procedures). (orig.) With 2 figs., 7 tabs., 14 refs.

  9. The Kjeldahl method as a primary reference procedure for total protein in certified reference materials used in clinical chemistry. II. Selection of direct Kjeldahl analysis and its preliminary performance parameters.

    Science.gov (United States)

    Vinklárková, Bára; Chromý, Vratislav; Šprongl, Luděk; Bittová, Miroslava; Rikanová, Milena; Ohnútková, Ivana; Žaludová, Lenka

    2015-01-01

    To select a Kjeldahl procedure suitable for the determination of total protein in reference materials used in laboratory medicine, we reviewed in our previous article Kjeldahl methods adopted by clinical chemistry and found an indirect two-step analysis by total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. In this article, we compare both procedures on various reference materials. An indirect Kjeldahl method gave falsely lower results than a direct analysis. Preliminary performance parameters qualify the direct Kjeldahl analysis as a suitable primary reference procedure for the certification of total protein in reference laboratories.

  10. Determination of rare earth and uranium in reference biological materials certified by the method of neutron activation analysis; Determinacao de terras raras e de uranio em materiais biologicos de referencia certificados pelo metodo de analise por ativacao com neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Lais H.P.; Saiki, Mitiko, E-mail: laispaciulli@gmail.com, E-mail: mitiko@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    The objective of this study was to evaluate the precision and accuracy of the determinations of Sc, La, Ce, Nd, Sm, Eu, Tb, Yb, Lu and U in certified reference materials (CRMs). To solve the problem of interference from fission products of U in the determination of lanthanides were obtained correction factors for this interference for {sup 140}La, {sup 141}Ce, {sup 143}Ce, {sup 153}Sm and {sup 147}Nd. The experimental procedure of Neutron Activation Analysis consisted of irradiating aliquots of each of the CRMs with synthetic standards of elements under thermal neutron flux of the IEA-R1 nuclear reactor, followed by gamma-ray spectrometry using a high-resolution hyperpurity GE detector. The analyzes of CRMs indicate good accuracy and precision of results, demonstrating the feasibility of applying of established procedure in NAA of elements studied in organic vegetable matrices.

  11. Elemental Quantification and Residues Characterization of Wet Digested Certified and Commercial Carbon Materials

    KAUST Repository

    Simoes, Filipa R. F.

    2016-10-25

    Inductively coupled plasma optical emission spectroscopy (ICP-OES) is a common, relatively low cost, and straightforward analytical technique for the study of trace quantities of metals in solid materials, but its applicability to nanocarbons (e.g., graphene and nanotubes) has suffered from the lack of efficient digestion steps and certified reference materials (CRM). Here, various commercial and certified graphitic carbon materials were subjected to a

  12. Preparação de um material de referência certificado para controle de agrotóxicos em hortifrutigranjeiros: estudo da homogeneidade Preparation of a certified reference material for pesticide control in the cultivation of fruits and vegetables: a homogeneity study

    Directory of Open Access Journals (Sweden)

    Maria Helena Wohlers Morelli Cardoso

    2010-06-01

    Full Text Available Neste trabalho são apresentados os esforços para garantir a homogeneidade de um material de referência. Níveis residuais (mg.kg-1 de quatro agrotóxicos (γ-HCH, fenitrotiona, clorpirifós e procimidona foram adicionados à polpa de tomate com o objetivo de se preparar um material de referência certificado. As propriedades mais importantes desses materiais são a homogeneidade e a estabilidade. Antes de serem enviados a outros laboratórios, os materiais de referência precisam ter sua homogeneidade verificada. Nas etapas prévias, amostras foram avaliadas de modo a prover dados sobre o tratamento mais adequado para minimizar a variabilidade analítica do lote preparado e garantir a qualidade da amostra candidata a material de referência certificado, tão bem como a estimativa da incerteza associada à homogeneidade. A análise de variância fornece informações sobre a variabilidade do lote preparado e o grau de invariabilidade da amostra fortificada. Depois da preparação, as amostras foram expostas à radiação gama na dose de 2 kGy e submetidas a um estudo interlaboratorial para certificação. As concentrações certificadas dos agrotóxicos após caracterização foram 0,191 ± 0,047 mg.kg-1; 0,192 ± 0,068 mg.kg-1; 0,225 ± 0,076 mg.kg-1e 0,177 ± 0,051 mg.kg-1 para o γ-HCH, a fenitrotiona, clorpirifós e procimidona respectivamente.This study reports on the efforts to ensure homogeneity of certified reference materials. Residues of four pesticides (γ-HCH, fenitrothion, chlorpyrifos, and procymidone were added to tomato pulp in order to produce reference materials. The two most important properties of such materials are known to be homogeneity and stability. Before being shipped to other laboratories, reference materials must have their homogeneity certified. As part of a preliminary study, hundreds of samples were investigated in order to provide data on the most suitable treatments to minimize analytical variability and

  13. Stability evaluation and chemical characterization of different vegetable oils viewing the search for candidates for certified reference materials for bio diesel; Avaliacao da estabilidade e caracterizacao quimica de diferentes oleos vegetais visando a busca de candidatos a materiais de referencia certificado (MRC) para biodiesel

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, Georgiana F. da; Fonseca, Mauricio G.; Goncalves, Lenise V.F.; Silva, Regina Celia F. da; Silva, Fernanda M.R. da; Rodrigues, Janaina M. [Instituto Nacional de Metrologia, Normalizacao e Qualidade Industrial (LABOR/INMETRO), Duque de Caxias, RJ (Brazil). Lab. de Analises Organicas; Leal, Rodrigo V.P. [Instituto Nacional de Metrologia, Normalizacao e Qualidade Industrial (LAMBOC/INMETRO), Duque de Caxias, RJ (Brazil). Lab. de Motores, Combustiveis e Lubrificantes], Email: rvleal@inmetro.gov.br; Cunha, Valnei S. [Instituto Nacional de Metrologia, Normalizacao e Qualidade Industrial (DIMCI/INMETRO), Duque de Caxias, RJ (Brazil). Diretoria de Metrologia Cientifica e Industrial

    2009-07-01

    Viewing the characterization of the various vegetable oils aiming to obtain a data bank that allows the production of certified reference materials for bio diesel of different blends, a study of chemical-physical characterization of different oils and derivative of bio diesel.

  14. The Certification of Methamphetamine Certified Reference Material and its Uncertainty Evaluation%甲基苯丙胺标准物质的定值与不确定度分析

    Institute of Scientific and Technical Information of China (English)

    张盼; 苏福海; 王海峰; 李红梅; 杨晶

    2012-01-01

    为了建立法庭科学毒品检测量值溯源体系,研制了甲基苯丙胺纯度标准物质。通过红外光谱、质谱法对甲基苯丙胺样品进行定性分析,优化并建立了高效液相色谱(HPLC)、差示扫描量热法(DSC)两种定值分析方法。采用热重分析法和电感耦合等离子体质谱法测定水分和无机离子的含量。通过均匀性与稳定性检验结果表明,甲基苯丙胺标准物质的均匀性良好,稳定性至少1年,同时对其进行了不确定度评定。研制的甲基苯丙胺标准物质的纯度为99.8%,扩展不确定度为0.2%(k=2)。%In order to establish the traceability system of detection value of drugs in forensic science,methamphetamine was prepared and certified as pure certified reference material(CRM).The structure of the material was qualitatively identified by IR and MS techniques.Then the principal component value was obtained through establishing the methods of HPLC and DSC.The contents of water and inorganic ion were determined by TGA and ICP-MS.Meanwhile,the uncertainty was evaluated.The test results of the homogeneity and stability showed that prepared methamphetamine had good uniformity and was stable at least 1 year,its purity was 99.8% and the expanded uncertainty was 0.2%(k=2).

  15. Preparação de um material de referência certificado para controle de agrotóxicos em hortifrutigranjeiros: estudo da estabilidade Preparation of a certified reference material for pesticide control in the cultivation fruits and vegetables: a stability study

    Directory of Open Access Journals (Sweden)

    Maria Helena Wohlers Morelli Cardoso

    2010-06-01

    Full Text Available Neste trabalho são apresentados os resultados dos estudos de estabilidade referentes à produção de um material de referência certificado. Foram avaliados níveis residuais de concentração dos agrotóxicos γ-HCH, fenitrotiona, clorpirifós e procimidona em polpa de tomate. A pasteurização e a irradiação gama foram empregadas à polpa de tomate, visando manter a integridade da amostra candidata a material de referência. A polpa foi preparada e dividida em duas partes. Cada parte foi fortificada com os referidos agrotóxicos na faixa de concentração de 0,1 a 0,2 mg.kg-1. Uma das partes foi submetida à pasteurização a 90 °C por 4 minutos e a outra parte foi irradiada com dose de 2,0 kGy depois de homogeneizada. A estabilidade e a incerteza da amostra, correspondente ao período de tempo avaliado, foram determinadas através da análise de regressão em conjunto com a ANOVA. Os resultados indicaram que ambos os procedimentos de preparo da amostra são adequados para a conservação da polpa de tomate fortificada com os quatro agrotóxicos, com vantagem para o tratamento por irradiação com a dose de 2,0 kGy.This research presents the results of stability studies regarding the production of certified reference materials. The residual concentration levels of four pesticides, namely γ-HCH, fenitrothion, chlorpyrifos, and procymidone were investigated. Pasteurization combined with gamma irradiation was used to maintain the integrity of the mixture tested as a reference material candidate. The pulp was prepared and split into two parts. Each part was then spiked with those pesticides in the concentration range of 0.1 to 0.2 mg.kg-1 in tomato pulp. One of them was submitted to pasteurization at 90 °C for 4 minutes after being homogenized, and the other was irradiated with a gamma dose of 2.0 kGy. The material stability and the corresponding uncertainty during the period of time evaluated were determined using regression analysis and

  16. Development of synthetic environmental radioactivity reference materials.

    Science.gov (United States)

    Harms, Arvic; Gilligan, Chris

    2012-09-01

    In this paper, a novel way of developing synthetic environmental radioactivity reference materials via the sol-gel process is described. Two solid reference materials (both having a SiO(2) matrix) were synthesised by hydrolysing a liquid mixture of tetraethyl orthosilicate (TEOS), ethanol and standardised mixed radionuclide solutions. The certified values, which were in the Bqg(-1) range, for the radionuclides in the material were determined by NPL and compared with results from measurements made by 36 organisations from 17 countries using a 'consensus' approach. The measurements were made within two wider test exercises (the NPL Environmental Radioactivity Proficiency Test Exercises 2009 and 2010). Certified activity concentration values were obtained for (60)Co, (133)Ba, (134)Cs, (137)Cs, (152)Eu, (154)Eu and (241)Am and indicative values were obtained for (55)Fe and (90)Sr.

  17. Reference materials and representative test materials: the nanotechnology case

    Energy Technology Data Exchange (ETDEWEB)

    Roebben, G., E-mail: gert.roebben@ec.europa.eu [Joint Research Centre of the European Commission, Institute for Reference Materials and Measurements (Belgium); Rasmussen, K. [Joint Research Centre of the European Commission, Institute for Health and Consumer Protection (Italy); Kestens, V.; Linsinger, T. P. J. [Joint Research Centre of the European Commission, Institute for Reference Materials and Measurements (Belgium); Rauscher, H. [Joint Research Centre of the European Commission, Institute for Health and Consumer Protection (Italy); Emons, H. [Joint Research Centre of the European Commission, Institute for Reference Materials and Measurements (Belgium); Stamm, H. [Joint Research Centre of the European Commission, Institute for Health and Consumer Protection (Italy)

    2013-03-15

    An increasing number of chemical, physical and biological tests are performed on manufactured nanomaterials for scientific and regulatory purposes. Existing test guidelines and measurement methods are not always directly applicable to or relevant for nanomaterials. Therefore, it is necessary to verify the use of the existing methods with nanomaterials, thereby identifying where modifications are needed, and where new methods need to be developed and validated. Efforts for verification, development and validation of methods as well as quality assurance of (routine) test results significantly benefit from the availability of suitable test and reference materials. This paper provides an overview of the existing types of reference materials and introduces a new class of test materials for which the term 'representative test material' is proposed. The three generic concepts of certified reference material, reference material(non-certified) and representative test material constitute a comprehensive system of benchmarks that can be used by all measurement and testing communities, regardless of their specific discipline. This paper illustrates this system with examples from the field of nanomaterials, including reference materials and representative test materials developed at the European Commission's Joint Research Centre, in particular at the Institute for Reference Materials and Measurements (IRMM), and at the Institute for Health and Consumer Protection (IHCP).

  18. A DANREF certified reference plastic for measurement of overall migration into the food simulant olive oil by single sided testing

    DEFF Research Database (Denmark)

    Lund, K. H.; Lillemark, L.; Petersen, Jens Højslev

    2000-01-01

    A reference material for the determination of overall migration from a plastic coextrudate into the fatty food simulant olive oil was produced and certified in an interlaboratory study. The analyses were carried out according to the ENV 1186 standard from the European Committee for Standardization...... (CEN) [1, 2, 3] with exposure of the coextrudate to olive oil for 10 days at 40 degrees C. After an initial preliminary interlaboratory study eight laboratories participated in the certification round, and two different methods were used to obtain single sided exposure of the plastic to the oil...

  19. Homogeneity studies in reference materials with Zeeman solid sampling GFAAS

    Energy Technology Data Exchange (ETDEWEB)

    Mohl, C.; Stoeppler, M.; Grobecker, K.H.

    1987-09-01

    The homogeneity of lead and cadmium in reference materials was investigated by solid sampling GFAAS. The following materials were comparatively analyzed: Standard reference materials from NBS, Washington 1567 wheat flour, 1568 rice flour and 1577a bovine liver, certified reference materials from BCR, Brussels, No 63 milk powder, No 184 bovine muscle, No 185 bovine liver, No 186 pig kidney, No 189 wholemeal flour, No 191 brown bread and a whole fish (dab) homogenate from the environmental specimen bank in the FRG. The results are remarkably different for the investigated materials.

  20. Reference Materials for Reactor Neutron Fluence Rate and Temperature Measurements

    Science.gov (United States)

    Ingelbrecht, C.

    2003-06-01

    Certified reference materials are distributed by the European Commission through the BCR® programme (over 500 CRMs) including a series of activation and fission monitor materials originally proposed by the Euratom Working Group on Reactor Dosimetry. The current range (18 CRMs) includes materials to cover the complete energy spectrum, and suitable for different irradiation times. Fission monitors are 238UO2 or 237NpO2 in the form of microspheres. Activation monitors are high purity metals (Ni, Cu, Al, Fe, Nb, Rh, or Ti), certified for interfering trace impurities, or dilute aluminium-based alloys. Reference materials newly certified are IRMM-530R A1-0.1%Au, replacing the exhausted IRMM-530 material, used as comparator for k0- standardisation, and three new Al-Co alloys (0.01, 0.1 and 1.0%Co). Others in the process of certification are A1-0.1%Ag and A1-2%Sc for thermal and epithermal fluence rate measurements and two uranium-doped glass materials intended for dosimetry by the fission-track technique. Various alloy compositions have been prepared for use as melt-wire temperature monitors with melting points ranging from 198 to 327ºC.

  1. The new IAEA reference material: IAEA-434 technologically enhanced naturally occurring radioactive materials (TENORM) in phosphogypsum

    Energy Technology Data Exchange (ETDEWEB)

    Shakhashiro, A., E-mail: A.Shakhashiro@iaea.or [International Atomic Energy Agency, Agency' s Laboratories, Vienna International Center, PO Box 100, A-1400 Vienna (Austria); Sansone, U. [International Atomic Energy Agency, Agency' s Laboratories, Vienna International Center, PO Box 100, A-1400 Vienna (Austria); Wershofen, H. [Environmental Radioactivity, PTP, Braunschweig (Germany); Bollhoefer, A. [Environmental Radioactivity, Department of the Environment and Heritage, Darwin (Australia); Kim, C.K. [International Atomic Energy Agency, Agency' s Laboratories, Vienna International Center, PO Box 100, A-1400 Vienna (Austria); Kim, C.S. [Department of Environmental Radioactivity Assessment, Korea Institute of Nuclear Safety, Daejeon, Republic of Korea (Former collaborator) (Korea, Republic of); Kis-Benedek, G. [International Atomic Energy Agency, Agency' s Laboratories, Vienna International Center, PO Box 100, A-1400 Vienna (Austria); Korun, M. [Jozef Stefan Institute, Ljubljana (Slovenia); Moune, M. [LNE-LNHB, Laboratoire National Henri Becquerel, Gif-sur-Yvette Cedex (France); Lee, S.H. [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of); Tarjan, S. [Central Radiological Laboratory, Hungarian Agricultural Authority, Budapest (Hungary); Al-Masri, M.S. [Atomic Energy Commission of Syria, Damascus (Syrian Arab Republic)

    2011-01-15

    A reliable determination of Technologically Enhanced Naturally Occurring Radioactive Materials in phosphogypsum is necessary to comply with radiation protection and environmental regulations. In this respect, a new phosphogypsum reference material was produced and certified to assist in the validation of analytical methods and the quality assurance of produced analytical results. This paper presents the sample preparation methodology, material homogeneity assessment, characterization campaign results and assignment of property values, and associated uncertainties. The reference values and associated uncertainties for Pb-210, Ra-226, Th-230, U-234 and U-238 were established based on consensus values calculated from analytical results reported by three National Metrology Institutes and five expert laboratories.

  2. The new IAEA reference material: IAEA-434 technologically enhanced naturally occurring radioactive materials (TENORM) in phosphogypsum.

    Science.gov (United States)

    Shakhashiro, A; Sansone, U; Wershofen, H; Bollhöfer, A; Kim, C K; Kim, C S; Kis-Benedek, G; Korun, M; Moune, M; Lee, S H; Tarjan, S; Al-Masri, M S

    2011-01-01

    A reliable determination of Technologically Enhanced Naturally Occurring Radioactive Materials in phosphogypsum is necessary to comply with radiation protection and environmental regulations. In this respect, a new phosphogypsum reference material was produced and certified to assist in the validation of analytical methods and the quality assurance of produced analytical results. This paper presents the sample preparation methodology, material homogeneity assessment, characterization campaign results and assignment of property values, and associated uncertainties. The reference values and associated uncertainties for Pb-210, Ra-226, Th-230, U-234 and U-238 were established based on consensus values calculated from analytical results reported by three National Metrology Institutes and five expert laboratories.

  3. Certification of elements in and use of standard reference material 3280 multivitamin/multielement tablets

    Science.gov (United States)

    Standard Reference Material (SRM) 3280 Multivitamin/Multielement Tablets was issued by the National Institute of Standards and Technology (NIST) in 2009 and has certified and reference mass fraction values for 13 vitamins, 26 elements, and 2 carotenoids. Elements were measured using two or more ana...

  4. Certification for copper concentration in reference material for fuel anhydro ethylic alcohol; Certificacao da concentracao de cobre em material de referencia para alcool etilico anidro combustivel (AEC)

    Energy Technology Data Exchange (ETDEWEB)

    Reis, Lindomar Augusto dos; Rocha, Marcia Silva da; Mesko, Marcia Foster; Silva, Fagner Francisco da; Quaresma, Maria Cristina Baptista; Araujo, Thiago Oliveira [Instituto Nacional de Metrologia, Normalizacao e Qualidade Industrial (DIMCI/INMETRO), Duque de Caxias, RJ (Brazil). Diretoria de Metrologia Cientifica e Industrial], E-mail: lareis@inmetro.gov.br

    2009-07-01

    This work aiming to obtain the first certified reference material for fuel anhydro ethylic alcohol relative to the copper concentration, which has his maximum limit determined by the in force legislation providing traceability and reliability for the measurement results.

  5. Reference material for radionuclides in sediment IAEA-384 (Fangataufa Lagoon sediment)

    DEFF Research Database (Denmark)

    Povinec, P.P.; Pham, M.K.; Sanchez-Cabeza, J.A.;

    2007-01-01

    A reference material designed for the determination of anthropogenic and natural radionuclides in sediment, IAEA-384 (Fangataufa Lagoon sediment), is described and the results of certification are presented. The material has been certified for 8 radionuclides (K-40, Co-60, Eu-155, Th-230, U-238, ...

  6. Primary certification of reference material for electrolytic conductivity of bioethanol

    Science.gov (United States)

    da Silva, L. F.; Gomes, M. R. F.; Cassini, G. C.; Faria, A. C. V.; Fraga, I. C. S.

    2016-07-01

    Nowadays the preservation of the planet is spreading into the international scene with the use of renewable energy sources such as bioethanol. The challenge is to guarantee the quality of produced bioethanol, and the electrolytic conductivity (EC) is one of the specified parameters for this purpose. However, is necessary to demonstrate the metrological traceability of the measurement results for EC in this matrix. This study presents the certification of a reference material for EC in bioethanol by using only primary measurements. The value of primary certified reference material (CRM) is (0.77 ± 0.06) µS.cm-1, and its use will provide the metrological traceability needed for measurement results in laboratories.

  7. Preparation and characterization of the fish reference material; Preparacao e caracterizacao de um material de referencia de peixe

    Energy Technology Data Exchange (ETDEWEB)

    Ulrich, Joao Cristiano

    2011-07-01

    The certified reference materials (CRMs) play an important role in obtaining measurement results traceable to the International System of Units, through an unbroken chain of comparisons. Thus, the demand for new certified reference materials (CRMs) increases every day in all areas of knowledge. The availability of reference materials, mainly in Brazil is still incipient, given that the demand far exceeds the available variety of these materials. The amount of certified reference materials available in the country is insufficient to meet the need of the scientific community and demands for development of new methodologies. Among the many areas in need of reference materials, we highlight the importance for the food trade balance for these products within the country. The certification of food products, intended both for export and for domestic consumption, requires analysis methods that provide precise and accurate results to ensure product quality. This paper describes the preparation and certification of a reference material in the fish matrix in mercury and methylmercury. The study brings together since the stage of material selection, preparation, development of homogeneity and stability studies and characterization. The certification was performed by means of measurements using two analytical techniques, flow injection analysis - cold vapor atomic absorption spectrometry (FIA-CV-AAS) and isotope dilution applied to mass spectrometry (IDMS), which is a primary method. In this work the standards of the ISO 30 (ABNT 30-34) and ISO Guide 35 was used as the basis for the preparation and characterization of the material. For the calculation of uncertainties was used the GUM and Eurachem guide. As a result, was produced and certified a lot of material in relation to the concentration of mercury (Hg = 0.271 {+-} 0.057 mg g{sup -1}) and methylmercury (MeHg = 0.245 {+-} 0.038 mg g{sup -1}), and informational values of lead and arsenic. (author)

  8. History of reference materials for food and nutrition metrology: As represented in the series of BERM Symposia

    Science.gov (United States)

    Establishment of a metrology-based measurement system requires the solid foundation of traceability of measurements to available, appropriate certified reference materials (CRM). In the early 1970s the first “biological” Reference Material (RM) of Bowens Kale, Orchard Leaves, and Bovine Liver from ...

  9. Speciation of dimethylarsinyl-riboside derivatives (arsenosugars) in marine reference materials by HPLC-ICP-MS

    DEFF Research Database (Denmark)

    Larsen, Erik Huusfeldt

    1995-01-01

    (cf. Table 2) were present in shellfish certified reference materials (CRMs) and in a lobster hepatopancreas CRM. The concentration of the two arsenosugars in the shellfish samples amounts to 18% of the total arsenic as compared to arsenobetaine at 9–13% and dimethylarsinate at 4–9% of the total...

  10. Reference Materials for Food and Nutrition Metrology: Past, Present and Future

    Science.gov (United States)

    Establishment of a metrology-based measurement system requires the solid foundation of traceability of measurements to available, appropriate certified reference materials (CRM). In the early 1970’s the first “biological” RM of Bowens Kale, as well as Orchard Leaves and Bovine Liver SRMs, from the ...

  11. Lawrence Livermore National Laboratory Working Reference Material Production Pla

    Energy Technology Data Exchange (ETDEWEB)

    Wong, Amy; Thronas, Denise; Marshall, Robert

    1998-11-04

    This Lawrence Livermore National Laboratory (LLNL) Working Reference Material Production Plan was written for LLNL by the Los Alamos National Laboratory to address key elements of producing seven Pu-diatomaceous earth NDA Working Reference Materials (WRMS). These WRMS contain low burnup Pu ranging in mass from 0.1 grams to 68 grams. The composite Pu mass of the seven WRMS was designed to approximate the maximum TRU allowable loading of 200 grams Pu. This document serves two purposes: first, it defines all the operations required to meet the LLNL Statement of Work quality objectives, and second, it provides a record of the production and certification of the WRMS. Guidance provided in ASTM Standard Guide C1128-89 was used to ensure that this Plan addressed all the required elements for producing and certifying Working Reference Materials. The Production Plan was written to provide a general description of the processes, steps, files, quality control, and certification measures that were taken to produce the WRMS. The Plan identifies the files where detailed procedures, data, quality control, and certification documentation and forms are retained. The Production Plan is organized into three parts: a) an initial section describing the preparation and characterization of the Pu02 and diatomaceous earth materials, b) middle sections describing the loading, encapsulation, and measurement on the encapsulated WRMS, and c) final sections describing the calculations of the Pu, Am, and alpha activity for the WRMS and the uncertainties associated with these quantities.

  12. Developing a matrix reference material for screening of transgenic rice.

    Science.gov (United States)

    Li, Jun; Wu, Yuhua; Li, Xiaofei; Wang, Yulei; Zhang, Li; Li, Yunjing; Wu, Gang

    2015-12-01

    Certified reference materials (CRMs) that are compatible with detection methods are needed to detect genetically modified organisms (GMOs). Screening is the first detection step in determining the possible presence of GMO ingredients in food or feed; however, screening has been hindered by the lack of GMO CRMs. In this study, transgenic rice materials were developed via the transformation of a construct harboring 11 commonly used screening elements. Digital PCR was utilized to identify a homozygous single-copy line termed SDrice. The qualitative detections of 11 elements in 21 transgenic materials demonstrated that the genomic DNA of the SDrice was suitable for use as a positive control in the screening of GMO ingredients. The suitability of SDrice as reference material was further checked by testing the sensitivity of 11 known conventional PCR assays, ranging from 10 to 50 copies of the SDrice genome. The standard curves that were created using SDrice DNA series as calibrators all exhibited good linearities in the relationships of the Ct values with the template copy numbers in these 11 real-time PCR assays. The LODs of the real-time PCR assays were estimated to be two to five copies of the SDrice genome. Comparisons of the SDrice with other GM rice revealed that significant differences existed in both the intercepts of the standard curves and the ΔCt values of the exogenous and reference genes for the P-35S, T-nos, HPT, T-35S, and Bar assays; the SDrice was not fit for quantification of other GM rice events. This study provided a matrix reference material (RM) that was suitable for screening GM rice, determination of sensitivity and a LOD of PCR assays, and overcame some of the drawbacks of plasmid DNA as reference material.

  13. delta 15N and non-carbonate delta 13C values for two petroleum source rock reference materials and a marine sediment reference material

    Science.gov (United States)

    Dennen, Kristin O.; Johnson, Craig A.; Otter, Marshall L.; Silva, Steven R.; Wandless, Gregory A.

    2006-01-01

    Samples of United States Geological Survey (USGS) Certified Reference Materials USGS Devonian Ohio Shale (SDO-1), and USGS Eocene Green River Shale (SGR-1), and National Research Council Canada (NRCC) Certified Marine Sediment Reference Material (PACS-2), were sent for analysis to four separate analytical laboratories as blind controls for organic rich sedimentary rock samples being analyzed from the Red Dog mine area in Alaska. The samples were analyzed for stable isotopes of carbon (delta13Cncc) and nitrogen (delta15N), percent non-carbonate carbon (Wt % Cncc) and percent nitrogen (Wt % N). SDO-1, collected from the Huron Member of the Ohio Shale, near Morehead, Kentucky, and SGR-1, collected from the Mahogany zone of the Green River Formation are petroleum source rocks used as reference materials for chemical analyses of sedimentary rocks. PACS-2 is modern marine sediment collected from the Esquimalt, British Columbia harbor. The results presented in this study are, with the exceptions noted below, the first published for these reference materials. There are published information values for the elemental concentrations of 'organic' carbon (Wt % Corg measured range is 8.98 - 10.4) and nitrogen (Wt % Ntot 0.347 with SD 0.043) only for SDO-1. The suggested values presented here should be considered 'information values' as defined by the NRCC Institute for National Measurement Reference Materials and should be useful for the analysis of 13C, 15N, C and N in organic material in sedimentary rocks.

  14. 40 CFR 91.6 - Reference materials.

    Science.gov (United States)

    2010-07-01

    ... forth material from the Society of Automotive Engineers which has been incorporated by reference. The... Automotive Engineers International, 400 Commonwealth Dr., Warrendale, PA 15096-0001. Document number and name.... (1) ASTM material. The following table sets forth material from the American Society for Testing...

  15. Overview of Uranium Isotopic Reference Materials at IRMM

    Science.gov (United States)

    Alonso-Munoz, A.; Richter, S.; Eykens, R.; Aregbe, Y.; Kuehn, H.; Verbruggen, A.

    2007-12-01

    For many applications in the geological sciences, in particular in geochemistry research, isotope ratio measurements play a significant role. For instance, in geochronology isotope abundances of uranium and its daughter products thorium and lead have been used since more than five decades to determine the age of various samples of geological interest. However, in order to validate mass spectrometric measurement procedures and to calibrate detector systems, suitable isotope reference materials are needed. IRMM is a well recognized provider for nuclear isotope reference materials to the nuclear industry and nuclear safeguards authorities, which can also be used for geological applications. This paper gives an overview of isotope reference materials for uranium prepared and certified at IRMM. These materials are synthetic isotope reference materials prepared based on proven methods of purifying and mixing highly enriched oxides. Firstly, a set of 10 mixtures of 233U, 235U and 238U was made in which the 235U/238U ratios were kept at 1:1 and the 233U/235U ratios varied from 1.0 to 10-6 (IRMM-072). This set is ideal for checking the linearity response of detectors used in isotope mass spectrometry. Recently, after the IRMM-072 series was exhausted, it has been replaced by the IRMM-073 and IRMM-074 series. Secondly the double spike IRMM-3636 with a 233U/236U ratio of 1:1 was prepared which allows internal mass fractionation correction for high precision 235U/238U ratio measurements. The 234U abundance of this double spike material is low enough to allow an accurate and precise correction of 234U/238U ratios, even for measurements of close to equilibrium uranium samples.

  16. Certification of B-group vitamins (b1, b2, b6, and b12) in four food reference materials

    NARCIS (Netherlands)

    Ollilainen, V.; Finglas, P.M.; Berg, H. van den; Froidmont-Görtz, I. de

    2001-01-01

    In 1989, the Community Bureau of Reference started a research program to improve the quality of vitamin analysis in food. To achieve this task, vitamin methodology was evaluated and tested by interlaboratory studies and the preparation of certified reference materials, which will be used for quality

  17. Reference to the Safety Engineering Undergraduate Courses to Improve the Subjects and Contents of the Certified Safety Engineer Qualification and Examination System of China

    Directory of Open Access Journals (Sweden)

    Haibin Qiu

    2013-10-01

    Full Text Available The aim of this paper is to recommend that the subjects and contents of certified safety engineers use safety engineering undergraduate curriculum system for reference. Human resources play an important role in accident prevention and loss control. Education on safety engineering develops quickly in China. Moreover, the State Administration of Work Safety and the National Human Resources and Social Security Ministry have implemented a certified safety engineer qualification and examination system. The content of the four core curriculum of safety engineering-1 principles of safety science, 2 system safety engineering, 3 ergonomics and 4 safety management-can be clearly delineated. However, the content division of four examination subjects of certified safety engineers examination-1 production safety law and related legal knowledge, 2 safety production management knowledge, 3 safety production technology and 4 case studies of safety production accidents- has a lot of crossover. There is no conflict between the fundamental purposes of professional safety education and certified safety engineers qualification and examination system. Safety engineering undergraduate curriculum covers the content of a certified safety engineer examination.

  18. Polyfluorinated substances in abiotic standard reference materials

    NARCIS (Netherlands)

    Reiner, J.L.; Blaine, A.C.; Higgins, C.P.; Kwadijk, C.J.A.F.

    2015-01-01

    The National Institute of Standards and Technology (NIST) has a wide range of Standard Reference Materials (SRMs) which have values assigned for legacy organic pollutants and toxic elements. Existing SRMs serve as homogenous materials that can be used for method development, method validation, and m

  19. Certification of a meat reference material based on a collaborative study

    Directory of Open Access Journals (Sweden)

    Claudia Marcela Salazar Arzate

    2013-01-01

    Full Text Available Through a collaborative project, comparison studies were carried out to improve measurement capabilities of participating laboratories, supporting them to produce, characterize and distribute reference materials in the food sector. The project was planned in four annual stages (milk, water, meat and grains. The third stage aimed specifically to quantify and certify the nutritional content of the parameters (nitrogen, fat, sodium and potassium of a batch candidate as Certified Reference Material (CRM of canned beef. This study was conducted in collaboration between several National Metrology Institutes (NMIs and/or collaborating laboratories, which, once identified the possible causes of variability or bias in the measurements, as well as the opportunities of improvement, achieved the certification of the material beef. The CRM was distributed among the participants to cover the needs of the food industry of meat products and testing laboratories in their respective countries.

  20. Myths of Isotopic Reference Materials Busted

    Science.gov (United States)

    Coplen, T.

    2007-12-01

    During the past several years, the determination of the isotopic abundances of elements including H, Li, B, C, N, O, Mg, Si, S, Cl, Ca, Cr, Fe, Cu, Zn, Tl, and Se has substantially increased because of expanded use in hydrology, environmental studies, microbiology, forensic investigations, atmospheric investigations, oceanography, etc. Improvements in instrumentation enable increasingly precise isotope-amount-ratio measurements in these fields, but these improvements in precision commonly do not lead to improvements in accuracy because of the lack or improper use of isotopic reference materials. When properly used, these critically important materials enable any laboratory worldwide to measure the same homogeneous sample and report the same isotopic abundance within analytical uncertainty. For example, for stable isotopic analysis of gaseous hydrogen samples, the agreement among 36 laboratories worldwide before normalization to any hydrogen gas reference material was 11.8 per mill. After normalization to anchors (gaseous H isotopic reference materials) at each end of the delta H-2 scale, the agreement was 0.85 per mill, an improvement of more than an order of magnitude. Consistency of delta C-13 measurements often can be improved by nearly 50 percent by anchoring the delta C-13 scale with two isotopic reference materials differing substantially in C-13 mole fraction, namely NBS 19 calcite and L-SVEC lithium carbonate. Agreement of delta C-13 values of four expert laboratories analyzing USGS40 L- glutamic acid by CF-IRMS methods improved from 0.084 to 0.015 per mill with use of the two scale anchors (NBS 19 and L-SVEC). Solid oxygen isotopic reference materials (IAEA-600 caffeine, IAEA-601 and IAEA-602 benzoic acids, IAEA-NO-3, USGS32, USGS34, and USGS35 nitrates, NBS-127, IAEA-SO-5, and IAEA-SO-6 barium sulfates) are poorly calibrated. Calibrating these solids to the VSMOW-SLAP reference water scale has been very difficult because both the solids and reference

  1. Agricultural biological reference materials for analytical quality control

    Energy Technology Data Exchange (ETDEWEB)

    Ihnat, M.

    1986-01-01

    Cooperative work is under way at Agriculture Canada, US Department of Agriculture, and US National Bureau of Standards in an attempt to fill some of the gaps in the world repertoire of reference materials and to provide much needed control materials for laboratories' day to day operations. This undertaking involves the preparation and characterization of a number of agricultural and food materials for data quality control for inorganic constituents. Parameters considered in the development of these materials were material selection based on importance in commerce and analysis; techniques of preparation, processing, and packaging; physical and chemical characterization; homogeneity testing and quantitation (certification). A large number of agricultural/food products have been selected to represent a wide range of not only levels of sought-for constituents (elements) but also a wide range of matrix components such as protein, carbohydrate, dietary fiber, fat, and ash. Elements whose concentrations are being certified cover some two dozen major, minor, and trace elements of nutritional, toxicological, and environmental significance.

  2. Preparation of Reference Material 8504, Transformer Oil

    OpenAIRE

    Poster, Dianne L.; Schantz, Michele M.; Wise, Stephen A.

    2005-01-01

    A new reference material (RM), RM 8504, has been prepared for use as a diluent oil with Aroclors in transformer oil Standard Reference Materials (SRMs) 3075 to 3080 and SRM 3090 when developing and validating methods for the determination of polychlorinated biphenyls (PCBs) as Aroclors in transformer oil or similar matrices. SRMs 3075-3080 and SRM 3090 consist of individual Aroclors in the same transformer oil that was used to prepare RM 8504. A unit of RM 8504 consists of one bottle containi...

  3. Preparation of Reference Material 8504, Transformer Oil.

    Science.gov (United States)

    Poster, Dianne L; Schantz, Michele M; Wise, Stephen A

    2005-01-01

    A new reference material (RM), RM 8504, has been prepared for use as a diluent oil with Aroclors in transformer oil Standard Reference Materials (SRMs) 3075 to 3080 and SRM 3090 when developing and validating methods for the determination of polychlorinated biphenyls (PCBs) as Aroclors in transformer oil or similar matrices. SRMs 3075-3080 and SRM 3090 consist of individual Aroclors in the same transformer oil that was used to prepare RM 8504. A unit of RM 8504 consists of one bottle containing approximately 100 mL of transformer oil. No additional constituents have been added to the oil.

  4. A reference material for dynamic displacement calibration

    Science.gov (United States)

    Davighi, A.; Hack, E.; Patterson, E.; Whelan, M.

    2010-06-01

    Calibration of displacement and strain measurement systems is an essential step in providing traceability and confidence in stress and strain distributions obtained from experiment and used to validate simulations employed in engineering design. Reference materials provide a simple, well-defined distribution of the measured quantity that can be traced to an international standard and can be used to assess the uncertainty associated with the measurement system. Previous work has established a reference material and procedure for calibrating optical systems for measuring static, in-plane strain distributions and also demonstrated its use. A new effort is in progress to extend this work to the measurement of three-dimensional displacement distributions induced by cyclic and dynamic loading, including transients and large-scale deformation. The first step in this effort has been to define both the essential and desirable attributes of a reference material for calibrating systems capable of measurements of dynamic displacement and strain. An international consortium of research laboratories, system designers, manufacturers and end-users has identified a list of attributes and members of the experimental mechanics community have been asked to weight the importance of these attributes. The attributes are being utilised to evaluate candidate designs for the reference material which have been generated through a series of brain-storming sessions within the consortium.

  5. Reference material systems: a sourcebook for material assessment

    Energy Technology Data Exchange (ETDEWEB)

    Bhagat, N. (ed.)

    1976-12-01

    A reference set of data related to material systems and a framework for carrying out the material technologies assessment are presented. While the bulk of renewables have been considered in this report, the nonrenewable materials dealt with here include structural materials only, such as steel, aluminum, cement and concrete, and bricks. The complete data set is supposed to include material flows, energy requirements, capital and labor inputs, and environmental effects for each process that a resource must go through to become a useful material for an end use. Although effort has been made to obtain as much information as possible, considerable gaps in data, apparent throughout this report, could not be avoided. A new material technology can be evaluated by substituting that technology for appropriate elements of the reference materials system and calculating the net change in material resource, energy, capital and labor requirements, and environmental impacts. This combination of information thus serves as a means of evaluating the potential benefits to be gained by research in various material technologies.

  6. Certified Schools

    Data.gov (United States)

    Department of Homeland Security — Certified schools must provide specific information regarding the school, the nature and requirements of the educational program, location and contact information,...

  7. Future needs and requirements for AMS {sup 14}C standards and reference materials

    Energy Technology Data Exchange (ETDEWEB)

    Scott, E. Marian E-mail: marian@stats.gla.ac.uk; Boaretto, Elisabetta; Bryant, Charlotte; Cook, Gordon T.; Gulliksen, Steinar; Harkness, Doug D.; Heinemeier, Jan; McGee, Edward; Naysmith, Philip; Possnert, Goran; Plicht, Hans van der; Strydonck, Mark van

    2004-08-01

    {sup 14}C measurement uses a number of standards and reference materials with different properties. Historically the absolute calibration of {sup 14}C measurement was tied to 1890 wood, through the 'primary' standard of NBS-OxI (produced by the National Bureau of Standards, now NIST - National Institute of Standards and technology) subsequently replaced by NBS-OxII. These are both internationally calibrated and certified materials, whose {sup 14}C activities are known absolutely. A second tier of materials, often called secondary standards or reference materials, and including internationally recognised materials such as ANU-sucrose (now also IAEA-C6), Chinese - sucrose and the IAEA C1-C6 series, augmented by additional oxalic acid samples are also used routinely. The activity of these materials has been estimated from large numbers of measurements made by many laboratories. Recently, further natural materials from the Third and Fourth International Radiocarbon Inter-comparisons (TIRI and FIRI) have been added to this list. The activities of these standards and reference materials span both the applied {sup 14}C age range and the chemical composition range of typical samples, but this is not achieved uniformly and there is a continuing need for reference materials for laboratory quality control and measurement-traceability purposes. In this paper, we review the development of {sup 14}C standards and reference materials and consider the future requirements for such materials within the {sup 14}C AMS community.

  8. Reference material manufacture and certification for the AVNG

    Energy Technology Data Exchange (ETDEWEB)

    Hauck, Danielle K [Los Alamos National Laboratory; Mac Arthur, Duncan [Los Alamos National Laboratory; Thron, Jonathan L [Los Alamos National Laboratory; Livke, Alexander [VNIIEF; Kondratov, Sergey [VNIIEF; Razinkov, Sergey [VNIIEF

    2010-01-01

    Testing and demonstration of any radiation measurement system requires the use of appropriate radioactive sources. The AVNG implementation that we describe is an attribute measurement system built by RFNC - VNIIEF in Sarov, Russia. The AVNG detects neutron and gamma radiation signatures and displays the three unclassified attributes of 'plutonium presence,' 'plutonium mass > 2 kg,' and 'plutonium isotopic ratio ({sup 240}Pu to {sup 239}Pu) < 0.1.' The AVNG was tested using a number of reference material (RM) sources with masses and isotopic ratios above and below these thresholds. The AVNG was demonstrated in June 2009 using several of these sources in addition to detector calibration sources. Since the AVNG was designed to measure multi-kg plutonium sources, the RM was manufactured specifically for use with this system. In addition, the RM was used to test the thresholds in the AVNG, so the size and composition of each RM was certified prior to use. In this presentation, we will describe the various steps in the manufacture and certification of these RM sources.

  9. Preparation and certification of arsenate [As(V)] reference material, NMIJ CRM 7912-a.

    Science.gov (United States)

    Narukawa, Tomohiro; Kuroiwa, Takayoshi; Narushima, Izumi; Jimbo, Yasujiro; Suzuki, Toshihiro; Chiba, Koichi

    2010-05-01

    Arsenate [As(V)] solution reference material, National Metrology Institute of Japan (NMIJ) certified reference material (CRM) 7912-a, for speciation of arsenic species was developed and certified by NMIJ, the National Institute of Advanced Industrial Science and Technology. High-purity As(2)O(3) reagent powder was dissolved in 0.8 M HNO(3) solution and As(III) was oxidized to As(V) with HNO(3) to prepare 100 mg kg(-1) of As(V) candidate CRM solution. The solution was bottled in 400 bottles (50 mL each). The concentration of As(V) was determined by four independent analytical techniques-inductively coupled plasma mass spectrometry, inductively coupled plasma optical emission spectrometry, graphite furnace atomic absorption spectrometry, and liquid chromatography inductively coupled plasma mass spectrometry-according to As(V) calibration solutions, which were prepared from the arsenic standard of the Japan Calibration Service system and whose species was guaranteed to be As(V) by NMIJ. The uncertainties of all the measurements and preparation procedures were evaluated. The certified value of As(V) in the CRM is (99.53 +/- 1.67) mg kg(-1) (k = 2).

  10. Development of NIST standard reference material 2373: Genomic DNA standards for HER2 measurements

    Directory of Open Access Journals (Sweden)

    Hua-Jun He

    2016-06-01

    Full Text Available NIST standard reference material (SRM 2373 was developed to improve the measurements of the HER2 gene amplification in DNA samples. SRM 2373 consists of genomic DNA extracted from five breast cancer cell lines with different amounts of amplification of the HER2 gene. The five components are derived from the human cell lines SK-BR-3, MDA-MB-231, MDA-MB-361, MDA-MB-453, and BT-474. The certified values are the ratios of the HER2 gene copy numbers to the copy numbers of selected reference genes DCK, EIF5B, RPS27A, and PMM1. The ratios were measured using quantitative polymerase chain reaction and digital PCR, methods that gave similar ratios. The five components of SRM 2373 have certified HER2 amplification ratios that range from 1.3 to 17.7. The stability and homogeneity of the reference materials were shown by repeated measurements over a period of several years. SRM 2373 is a well characterized genomic DNA reference material that can be used to improve the confidence of the measurements of HER2 gene copy number.

  11. Preparation and certification of arsenobetaine reference material NMIJ CRM 7901-a.

    Science.gov (United States)

    Narukawa, Tomohiro; Chiba, Koichi; Kuroiwa, Takayoshi; Yarita, Takashi; Takatsu, Akiko

    2007-09-01

    An arsenobetaine [(CH(3))(3)As(+)CH(2)COO(-)] solution reference material, NMIJ CRM 7901-a, intended for use in the speciation of arsenic compounds, was developed and certified by the National Metrology Institute of Japan (NMIJ), part of the National Institute of Advanced Industrial Science and Technology (AIST). The high-purity arsenobetaine powder was synthesized from trimethylarsine [(CH(3))(3)As], and it was dissolved in water in order to prepare 20 mg kg(-1) of arsenobetaine standard solution. The solution was bottled in 500 bottles (each containing 10 ml). Certification of the CRM for arsenobetaine was conducted by NMIJ. The concentration of As was determined by four independent analytical techniques (ICP-MS, ICP-OES, GFAAS and LC-ICP-MS), and each result was converted to the arsenobetaine concentration by applying an appropriate factor. The arsenobetaine concentration in the CRM was thus certified.

  12. Reference material for natural radionuclides in glass designed for underground experiments

    CERN Document Server

    Povinec, P P; Busto, J; Cerna, C; Degering, D; Hamajima, Y; Holy, K; Hult, M; Jeskovsky, M; Koehler, M; Kovacik, A; Laubenstein, M; Loaiza, P; Mamedov, F; Marquet, C; Mott, J; Mullerova, M; Perrot, F; Piquemal, F; Reyss, J -L; Saakyan, R; Simgen, H; Soule, B; Stanicek, J; Sykora, I; Stekl, I

    2015-01-01

    A reference material designed for the determination of natural radionuclides in solid samples (glass pellets) is described and the results of certification are presented. The material has been certified for 7 natural radionuclides (40K, 226Ra, 228Ra, 228Th, 232Th, 235U and 238U). An information value is given for 210Pb. Radon (222Rn) emanation experiments showed results comparable within participating laboratories, however, the number of data and precision was too low to carry out a certification process. The reference material may be used for quality management of analytical laboratories engaged in the high-sensitive analysis of radionuclides in the construction materials of detectors placed in ultra low background underground laboratories.

  13. An international evaluation of holmium oxide solution reference materials for wavelength calibration in molecular absorption spectrophotometry.

    Science.gov (United States)

    Travis, John C; Zwinkels, Joanne C; Mercader, Flora; Ruíz, Arquímedes; Early, Edward A; Smith, Melody V; Noël, Mario; Maley, Marissa; Kramer, Gary W; Eckerle, Kenneth L; Duewer, David L

    2002-07-15

    Commercial spectrophotometers typically use absorption-based wavelength calibration reference materials to provide wavelength accuracy for their applications. Low-mass fractions of holmium oxide (Ho2O3) in dilute acidic aqueous solution and in glass matrixes have been favored for use as wavelength calibration materials on the basis of spectral coverage and absorption band shape. Both aqueous and glass Ho2O3 reference materials are available commercially and through various National Metrology Institutes (NMIs). Three NMIs of the North American Cooperation in Metrology (NORAMET) have evaluated the performance of Ho3-(aq)-based Certified Reference Materials (CRMs) under "routine" operating conditions using commercial instrumentation. The study was not intended to intercompare national wavelength scales but to demonstrate comparability of wavelength measurements among the participants and between two versions of the CRMs. It was also designed to acquire data from a variety of spectrophotometers for use in a NIST study of wavelength assignment algorithms and to provide a basis for a possible reassessment of NIST-certified Ho3+(aq) band locations. The resulting data show a substantial level of agreement among laboratories, instruments, CRM preparations, and peak-location algorithms. At the same time, it is demonstrated that the wavelength comparability of the five participating instruments can actually be improved by calibrating all of the instruments to the consensus Ho3+(aq) band locations. This finding supports the value of absorption-based wavelength standards for calibrating absorption spectrophotometers. Coupled with the demonstrated robustness of the band position values with respect to preparation and measurement conditions, it also supports the concept of extending the present approach to additional NMIs in order to certify properly prepared dilute acidic Ho2O3 solution as an intrinsic wavelength standard.

  14. Candidate coffee reference material for element content: production and certification schemes adopted at CENA/USP

    Energy Technology Data Exchange (ETDEWEB)

    Tagliaferro, Fabio Sileno; Fernandes, Elisabete A. de Nadai; Bacchi, Marcio Arruda; Franca, Elvis Joacir de [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil). Lab. de Radioisotopos], e-mail: fabiotag@cena.usp.br, e-mail: lis@cena.usp.br, e-mail: mabacchi@cena.usp.br, e-mail: ejfranca@cena.usp.br; Bode, Peter; Bacchi, Marcio Arruda; Franca, Elvis Joacir de [Delft University of Technology, Delft (Netherlands). Interfaculty Reactor Inst.], e-mail: P.Bode@iri.tudelft.nl

    2003-07-01

    Certified reference materials (CRMs) play a fundamental role in analytical chemistry establishing the traceability of measurement results and assuring accuracy and reliability. In spite of the huge importance of measurements in the food sector, Brazil does not produce CRMs to supply the demand. Consequently the acquisition of CRMs depends on imports at high costs. The coffee sector needs CRMs, however there is no material that represents the coffee composition. Since 1998, the Laboratorio de Radioisotopos (LRi) of CENA/USP has been involved in analysis of coffee. During this period, knowledge has been accumulated about several aspects of coffee, such as system of cultivation, elemental composition, homogeneity of the material, possible contaminants and physical properties of beans. Concomitantly, LRi has concentrated efforts in the field of metrology in chemistry, and now all this expertise is being used as the basis for the production of a coffee certified reference material (CRM) for inorganic element content. The scheme developed for the preparation and certification of coffee RM relies on the ISO Guides 34 and 35. The approaches for selection, collection and preparation of the material, moisture determination method, homogeneity testing, certification and long-term stability testing are discussed and a time frame for the expected accomplishments is provided. (author)

  15. Preparation and certification of Re-Os dating reference materials: Molybdenites HLP and JDC

    Science.gov (United States)

    Du, A.; Wu, S.; Sun, D.; Wang, Shaoming; Qu, W.; Markey, R.; Stain, H.; Morgan, J.; Malinovskiy, D.

    2004-01-01

    Two Re-Os dating reference material molybdenites were prepared. Molybdenite JDC and molybdenite HLP are from a carbonate vein-type molybdenum-(lead)- uranium deposit in the Jinduicheng-Huanglongpu area of Shaanxi province, China. The samples proved to be homogeneous, based on the coefficient of variation of analytical results and an analysis of variance test. The sampling weight was 0.1 g for JDC and 0.025 g for HLP. An isotope dilution method was used for the determination of Re and Os. Sample decomposition and preconcentration of Re and Os prior to measurement were accomplished using a variety of methods: acid digestion, alkali fusion, ion exchange and solvent extraction. Negative thermal ionisation mass spectrometry and inductively coupled plasma-mass spectrometry were used for the determination of Re and 187Os concentration and isotope ratios. The certified values include the contents of Re and Os and the model ages. For HLP, the Re content was 283.8 ?? 6.2 ??g g-1, 187Os was 659 ?? 14 ng g-1 and the Re-Os model age was 221.4 ?? 5.6 Ma. For JDC, the Re content was 17.39 ?? 0.32 ng g-1, 187Os was 25.46 ?? 0.60 ng g-1 and the Re-Os model age was 139.6 ?? 3.8 Ma. Uncertainties for both certified reference materials are stated at the 95% level of confidence. Three laboratories (from three countries: P.R. China, USA, Sweden) joined in the certification programme. These certified reference materials are primarily useful for Re-Os dating of molybdenite, sulfides, black shale, etc.

  16. 用于早前寒武纪岩石Ar-Ar法定年的K-Ar法年龄国家二级标准物质——ZMT04白云母的定值结果%The certified results of ZMT04 muscovite reference material utilized for 40Ar/39Ar isotopic geochronological research on Early precambrian rocks in China.

    Institute of Scientific and Technical Information of China (English)

    桑海清; 王非; 龚俊峰; 周晶

    2013-01-01

    desirable for any relatively old sample.In that occasion,if the neutron flux monitor is much younger than the unknown age sample,the 40 Ar/39Ar ratio in standard may become very small,approaching a smaller limit value (≈3).Therefore,it is quite necessary to prepare an old age standard for the flux monitor of the 40 Ar-39 Ar method,especially for isotopic geochronological research on Early Precambrian rocks and meteorites.ZMT04 muscovite as K-Ar age geostandard of China,were separated from a pegmatite dike which occurs at Tianpishan area,in the southwest of Zhuozi County,Inner Mongolia of China.The pegmatite consists of muscovite,quartz and minor zircon,sphere etc.About 1080g of pure ZMT04 muscovite was obtained at the (10 × 1 × 0.02)mm fraction.The purity is about 100%.Following mixing,the ZMT04 muscovite was divided into 14 jars about 77g each.Each jar sample was further subdivided into14 aliquots about 5.51g each (total 196 aliquots).One aliquot (prefixed C) was retained for control analysis of K and 40Ar*,the other 13 aliquot of the same jar remain to be used fo interlabortory work.40Ar-39 Ar age spectrum of ZMT04 muscovite indicats that the muscovite has remained undisturbed since its crystallisation.The plateau age age is 1823 ± 15Ma.Thirteen stepwise hating Ar isotopic data of the muscovite give a 40Ar/39Ar isochron age of 1824 ± 15Ma and the initial 40Ar/36Ar ration of 288 ± 16,and the MSWD in the 40Ar/36Ar-39Ar/36Ar isochron diagram is 2.10.This age may represent the crystallization time of the muscovite in the pegmatite dike.The homogeneity tests and the certification analyses of 40Ar* and K in ZMT04 muscovite were performed according to the rules from the International Standard Organization (ISO) Guid 35 (1985) and primary referenc material technique of China (1994).During the homogeneity tests the analyses of K and 40Ar* in 77-600 hornblende,Hb3gr hornblende and BSP-1 hornblend were done and the results are almost coincident with their mean value

  17. Preparation and certification of the Polish reference material Virginia Tobacco Leaves (CTA-VTL-2) for inorganic trace analysis including microanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Dybczynski, R.; Polkowska-Motrenko, H.; Samczynski, Z.; Szopa, Z.

    1997-12-31

    A new Polish certified reference material Virginia Tobacco Leaves (CTA-VTL-2) for inorganic trace analysis including microanalysis has been prepared. Certification of the candidate reference material was based on the world-wide interlaboratory comparison in which 60 laboratories from 18 countries, participated using various analytical methods and techniques. Data evaluation performed by means of the new multifunctional software package -SSQC. Recommended values were assigned for 33 and `information` values for 10 elements, respectively. The validity of `certified` values was confirmed for several elements using `very accurate` methods developed in this Laboratory. (author). 47 refs, 28 figs, 12 tabs.

  18. 40 CFR 90.7 - Reference materials.

    Science.gov (United States)

    2010-07-01

    ... materials may be obtained from Society of Automotive Engineers International, 400 Commonwealth Dr....116; 90.509. (2) SAE material. The following table sets forth material from the Society of Automotive.... (1) ASTM material. The following table sets forth material from the American Society for Testing...

  19. Material control system simulator program reference manual

    Energy Technology Data Exchange (ETDEWEB)

    Hollstien, R.B.

    1978-01-24

    A description is presented of a Material Control System Simulator (MCSS) program for determination of material accounting uncertainty and system response to particular adversary action sequences that constitute plausible material diversion attempts. The program is intended for use in situations where randomness, uncertainty, or interaction of adversary actions and material control system components make it difficult to assess safeguards effectiveness against particular material diversion attempts. Although MCSS may be used independently in the design or analysis of material handling and processing systems, it has been tailored toward the determination of material accountability and the response of material control systems to adversary action sequences.

  20. 40 CFR 1065.1010 - Reference materials.

    Science.gov (United States)

    2010-07-01

    ... and Technology that we have incorporated by reference. The first column lists the number and name of... Procedures,” Amended July 30, 2002, Mobile Source Division, California Air Resources Board 1065.805...

  1. Experience with certifying borated stainless steel as a shipping cask basket material

    Energy Technology Data Exchange (ETDEWEB)

    Abbott, D.G. (EG and G Idaho, Inc., Idaho Falls, ID (USA)); Nickell, R.E. (Applied Science and Technology, Inc., Poway, CA (USA))

    1990-01-01

    The original cask designs for a cask demonstration project featured fuel baskets constructed of borated stainless steel (bss) as a structural material. The project is intended to demonstrate casks that can be used for both shipping and storing spent nuclear fuel assemblies. The baskets were intended to maintain the fuel assemblies in a subcritical array for both normal and accident conditions. The Nuclear Regulatory Commission, however, judged bss to be unacceptable as a structural material. The cask designs were subsequently modified. The knowledge gained during this cask demonstration project may be applicable to development of bss as a basket material in future cask design. 6 refs., 2 figs., 2 tabs.

  2. Experience with certifying borated stainless steel as a shipping cask basket material

    Energy Technology Data Exchange (ETDEWEB)

    Abbott, D.G. [Idaho National Engineering Lab., Idaho Falls, ID (United States); Nickell, R.E. [Applied Science and Technology, Poway, CA (United States)

    1990-10-01

    This paper discusses the original cask designs for a cask demonstration project that has featured fuel baskets constructed of borated stainless steel (bss) as a structural material. The project is intended to demonstrate casks that can be used for both shipping and storing spent nuclear fuel assemblies. The baskets were intended to maintain the fuel assemblies in a subcritical array for both normal and accident conditions. The Nuclear Regulatory Commission, judged bss to be unacceptable as a structural material. The cask designs were subsequently modified. The knowledge gained during this cask demonstration project may be applicable to development of bss as a basket material in future cask design.

  3. Two new reference materials based on tobacco leaves: certification for over a dozen of toxic and essential elements.

    Science.gov (United States)

    Samczyński, Zbigniew; Dybczyński, Rajmund S; Polkowska-Motrenko, Halina; Chajduk, Ewelina; Pyszynska, Marta; Danko, Bożena; Czerska, Elżbieta; Kulisa, Krzysztof; Doner, Katarzyna; Kalbarczyk, Paweł

    2012-01-01

    The preparation, certification, and characterization of two new biological certified reference materials for inorganic trace analysis have been presented. They are based on two different varieties of tobacco leaves, namely, Oriental Basma Tobacco Leaves (INCT-OBTL-5), grown in Greece, and Polish Virginia Tobacco Leaves (INCT-PVTL-6), grown in Poland. Certification of the materials was based on the statistical evaluation of results obtained in a worldwide interlaboratory comparison, in which 87 laboratories from 18 countries participated, providing 2568 laboratory averages on nearly 80 elements. It was possible to establish the certified values of concentration for many elements in the new materials, that is, 37 in INCT-OBTL-5 and 36 in INCT-PVTL-6, including several toxic ones like As, Cd, Hg, Pb, and so forth. The share and the role of instrumental analytical techniques used in the process of certification of the new CRMs are discussed.

  4. Recent production of candidate reference materials at IRMM

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, G.N.; Pauwels, J.; Le Guern, L.; Schimmel, H.; Trapmann, S. [Commission of the European Communities, Geel (Belgium). Joint Research Centre

    2001-06-01

    In the execution of its mission to promote a common European measurement system in support of EU policies, IRMM's Reference Materials Unit is currently involved in preparation of proficiency-testing samples and candidate reference materials. Recent work related to bovine spongiform encephalopathy in cows, genetically modified organisms, and a variety of environmental materials is described. (orig.)

  5. 40 CFR 92.5 - Reference materials.

    Science.gov (United States)

    2010-07-01

    ... § 92.113 ASTM D 1945-91, Standard Test Method for Analysis of Natural Gas by Gas Chromatography § 92... Supercritical Fluid Chromatography § 92.113 ASTM E 29-93a, Standard Practice for Using Significant Digits in... follows: Document number and name 40 CFR part 92 reference SAE Paper 770141, Optimization of a...

  6. AOAC INTERNATIONAL's Technical Division on Reference Materials (TDRM) Reference Materials Database.

    Science.gov (United States)

    Zink, Donna

    2016-09-01

    The Technical Division on Reference Materials (TDRM) of AOAC INTERNATIONAL recommends policy and criteria to facilitate the development and use of reference materials (RMs) in the validation, implementation, and routine use of AOAC INTERNATIONAL methods. To aid analysts in these areas, TDRM has developed a searchable online database to identify RMs suitable for use with AOAC Official Methods of Analysis(SM) (OMA). RMs can be queried by analyte, by analyte and matrix, or by the selection of an OMA, based on analytes and matrixes described within the scope of the selected method. Only essential information is included in the database, to maximize usefulness and minimize the effort required to keep information current. Additional information, such as measurement uncertainty and purchasing instructions, is available through a link to the producer's Web site, when that information is available online. Data sets are solicited on a voluntary basis from National Metrology Institutes and accredited producers. Consideration of ease-of-use and ease-of-operation is a guiding principle in this database, as is cost management.

  7. Corrosion reference for geothermal downhole materials selection

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, P.F. II, Smith, C.C.; Keeney, R.C.; Kirk, D.K.; Conover, M.F.

    1983-03-01

    Geothermal downhole conditions that may affect the performance and reliability of selected materials and components used in the drilling, completion, logging, and production of geothermal wells are reviewed. The results of specific research and development efforts aimed at improvement of materials and components for downhole contact with the hostile physicochemical conditions of the geothermal reservoir are discussed. Materials and components covered are tubular goods, stainless steels and non-ferrous metals for high-temperature downhole service, cements for high-temperature geothermal wells, high-temperature elastomers, drilling and completion tools, logging tools, and downhole pumps. (MHR)

  8. Phosphated minerals to be used as radioactive reference materials; Minerais fosfatados para serem utilizados como materiais de referencia radioativos

    Energy Technology Data Exchange (ETDEWEB)

    Braganca, M.J.C.S.; Tauhata, L. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiacoes Ionizantes (LNMRI); Clain, A.F. [Universidade Severino Sombra, Vassouras, RJ (Brazil); Moreira, I. [Pontificia Univ. Catolica do Rio de Janeiro (PUC/Rio), RJ (Brazil). Dept. de Quimica

    2003-07-01

    The production and the supplying of certified reference materials, or deliberated contaminated materials containing natural radionuclides for laboratories which analyses environmental samples are fundamentals for the correct measurements of their radioactive levels. This analysis quality represents a important step for the safeguards of the population health, and quality control of the imported and exported products, such as minerals, agricultural and raw materials. The phosphate rocks, containing significant concentrations of thorium, and used as raw material and fertilizers justified a study for better characterization and distinction to be used cas certified reference radioactive materials. Therefore, samples from the two carboanalytical-alkaline chimneys (Araxa and Catalao), and one from metasedimentar origin (Patos de Minas), distant 100 km from each other, were collected and chemical and cholecystographic characterized by optical emission, X-ray diffraction and fluorescence. The element concentrations were determined by neutron activation analysis, ICP-MS and ICP-AES. The results, after multivariate statistical analysis and study of correlations among elements, have shown geochemical similarities of the phosphates from Araxa and Catalao, and differences from Patos de Minas, despite of the geographic proximity. The concentration of thorium between 200 and 500 (mg/g) allows to use such minerals as reference materials.

  9. [Review of normal spectral emissivity standard reference materials].

    Science.gov (United States)

    Yu, Kun; Liu, Yu-Fang; Zhao, Yue-Jin

    2012-11-01

    In order to improve the accuracy of spectral emissivity measurement, standard reference materials of spectral emissivity as the dissemination of quantity in spectral emissivity measurement are used for the calibration of spectral emissivity measurement apparatus. In the present paper, firstly the standard reference materials data proposed by the American National Institute of Standards and Technology are introduced, and some underlying standard reference materials suggested by some metering departments in Europe are analyzed in detail For the standard reference material Armco iron and SiC proposed by some researchers, the advantages and disadvantages were explored. Finally, the characteristics of standard reference materials are summarized, and the future development of spectral emissivity measurement standard is prospected.

  10. Preparation and certification of hijiki reference material, NMIJ CRM 7405-a, from the edible marine algae hijiki (Hizikia fusiforme).

    Science.gov (United States)

    Narukawa, Tomohiro; Inagaki, Kazumi; Zhu, Yanbei; Kuroiwa, Takayoshi; Narushima, Izumi; Chiba, Koichi; Hioki, Akiharu

    2012-02-01

    A certified reference material, NMIJ CRM 7405-a, for the determination of trace elements and As(V) in algae was developed from the edible marine hijiki (Hizikia fusiforme) and certified by the National Metrology Institute of Japan (NMIJ), the National Institute of Advanced Industrial Science and Technology (AIST). Hijiki was collected from the Pacific coast in the Kanto area of Japan, and was washed, dried, powdered, and homogenized. The hijiki powder was placed in 400 bottles (ca. 20 g each). The concentrations of 18 trace elements and As(V) were determined by two to four independent analytical techniques, including (ID)ICP-(HR)MS, ICP-OES, GFAAS, and HPLC-ICP-MS using calibration solutions prepared from the elemental standard solution of Japan calibration service system (JCSS) and the NMIJ CRM As(V) solution, and whose concentrations are certified and SI traceable. The uncertainties of all the measurements and preparation procedures were evaluated. The values of 18 trace elements and As(V) in the CRM were certified with uncertainty (k = 2).

  11. The development of the first set of Brazilian reference materials for the petroleum sector; O desenvolvimento dos primeiros materiais de referencia nacionais para o setor de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Zucchini, Ricardo R. [Instituto de Pesquisas Tecnologicas (IPT), Sao Paulo, SP (Brazil). Agrupamento de Materiais de Referencia

    2004-07-01

    The petroleum sector uses a number of standardized tests to characterize raw materials and products. The development of in-company programs for assurance of measurement quality, the increasing need to demonstrate proficiency by means of certification schemes or by widely accepted metrological practices, have been promoting a more intensive use of certified reference materials, in calibration as well as in validation of measurement methods and also in order to show the qualification of the laboratories. In this paper it is presented the preparation, performed by IPT's Reference Materials Group, of the first set of reference materials specially developed considering the needs of the petroleum community. Briefly, are presented the identification of the demands from the users, selection of matrices, homogeneity tests and stability studies, and the certification of the new reference materials, which are four diesel fuel oils with certified sulfur contents and one material with flash point certified by TAG and Pensky-Martens methods. It is presented a summary of the certification process, performed by means of a combined effort of several professionals that are now working at laboratories of research institutions, refineries and other industries, universities, fuel monitoring facilities and in National Petroleum Agency. (author)

  12. 硅铝铁标准物质的研制%Development of reference materials of silicon-aluminium-iron

    Institute of Scientific and Technical Information of China (English)

    李凤超; 周振华; 周晨旭

    2011-01-01

    On the basis of the needs of reference materials of silicon-aluminum-iron in our country, two reference materials of silicon-aluminum-iron were prepared According to the requirements of technical standard of silicon-aluminum-iron alloy, the silicon-aluminum-iron alloy with different content and without air hole or impurities on surface was selected as raw materials. After removing outer skin and inclusions and serting, the samples were prepared in to block samples with diameter of 40-50 mm. Then, they were grinded to particles with size smaller than 2 mm by jaw crusher. After fully mixing, the samples were repeatedly grinded with sample preparation machine. All the samples were made to pass through 0.125 mm (120 grid) screen. The u-niformity and stability tests of prepared reference materials were performed. The results showed that the prepared reference material had good uniformity and stability. The characterisation analysis of three elements including silicon, aluminum and iron in reference material was performed by several laboratories. The analytical data were tested by Grubbs method, Cochran's theorem and Shapiro-wilks method. The results showed that the normality test values of prepared reference material were all higher than the value of 95 % confidence probability. The certified values exhibited normal distribution or approximately normal distribution.

  13. Preparation and certification of the Polish reference material `Oriental Tobacco Leaves` (CTA-OTL-1) for inorganic trace analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dybczynski, R.; Polkowska-Motrenko, H.; Samczynski, Z.; Szopa, Z. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1996-12-31

    A new Polish certified reference material `Oriental Tobacco Leaves` (CTA-OTL-1) for inorganic trace analysis was prepared. Fresh tobacco leaves of variety `Oriental` were dried, ground and sieved. All precautions were taken to avoid contamination of material with metals. The next step was homogenization. Preliminary homogeneity checking consisted in determining of Ca, Fe and K content by X-ray fluorescence. Final homogeneity testing was performed by neutron activation analysis determining Co, Cr, Fe and Rb. To assure long-term stability, the whole lot of material was sterilized by electron beam radiation. Certification of the candidate reference material was done on the basis of world-wide interlaboratory comparisons exercise in which 61 laboratories, using various analytical methods participated. (author). 30 refs, 12 tabs, 21 figs.

  14. The development and evaluation of reference materials for food microbiology.

    NARCIS (Netherlands)

    in 't Veld, P.H.

    1998-01-01

    Since 1986 the National Institute of Public Health and the Environment (RIVM) has worked on the development and evaluation of microbiological reference materials (RMs) with support from the European Communities Bureau of Reference (BCR), now called Standards Measurement and Testing (SM&T). The RMs a

  15. 230Th-234U Model-Ages of Some Uranium Standard Reference Materials

    Energy Technology Data Exchange (ETDEWEB)

    Williams, R W; Gaffney, A M; Kristo, M J; Hutcheon, I D

    2009-05-28

    The 'age' of a sample of uranium is an important aspect of a nuclear forensic investigation and of the attribution of the material to its source. To the extent that the sample obeys the standard rules of radiochronometry, then the production ages of even very recent material can be determined using the {sup 230}Th-{sup 234}U chronometer. These standard rules may be summarized as (a) the daughter/parent ratio at time=zero must be known, and (b) there has been no daughter/parent fractionation since production. For most samples of uranium, the 'ages' determined using this chronometer are semantically 'model-ages' because (a) some assumption of the initial {sup 230}Th content in the sample is required and (b) closed-system behavior is assumed. The uranium standard reference materials originally prepared and distributed by the former US National Bureau of Standards and now distributed by New Brunswick Laboratory as certified reference materials (NBS SRM = NBL CRM) are good candidates for samples where both rules are met. The U isotopic standards have known purification and production dates, and closed-system behavior in the solid form (U{sub 3}O{sub 8}) may be assumed with confidence. We present here {sup 230}Th-{sup 234}U model-ages for several of these standards, determined by isotope dilution mass spectrometry using a multicollector ICP-MS, and compare these ages with their known production history.

  16. Stability and homogeneity of microbiological reference materials: some statistical models

    NARCIS (Netherlands)

    Heisterkamp SH; Hoogenveen RT; van Strijp-Lockefeer NGWM; Hoekstra JA; Havelaar AH; Mooijman KA

    1991-01-01

    Microbiological reference materials are being developed by the RIVM since several years. These materials consist of capsules filled with milkpowder artificially contaminated with a bacteria test strain of choice (i.e. Escherichia coli, Enterobacter cloacae, Salmonella typhimurium). Both from long

  17. Evaluation of a reference material for glycated haemoglobin

    NARCIS (Netherlands)

    Weykamp, CW; Penders, TJ; Muskiet, FAJ; vanderSlik, W

    1996-01-01

    The use of lyophilized blood as a reference material for glycated haemoglobin was investigated with respect to IFCC criteria for calibrators and control materials. Ninety-two laboratories, using 11 methods, detected no changes in glycated haemoglobin content when the lyophilizate was stored for one

  18. Feasibility of a recombinant human apolipoprotein E reference material

    NARCIS (Netherlands)

    Schiele, F.; Barbier, A.; Visvikis, A.; Aggerbeck, L.; Rosseneu, M.; Havekes, L.; Huttinger, M.; Profilis, C.; Siest, G.

    1998-01-01

    The aim of this work was to prepare a recombinant apo E material and to determine its suitability as a reference material. We produced human apo E3 using recombinant DNA technology. The cDNA of human apo E3 was cloned in the pARHS bacterial expression vector and used to transfect E. Coli BL21 (DE3)

  19. A new basaltic glass microanalytical reference material for multiple techniques

    Science.gov (United States)

    Wilson, Steve; Koenig, Alan; Lowers, Heather

    2012-01-01

    The U.S. Geological Survey (USGS) has been producing reference materials since the 1950s. Over 50 materials have been developed to cover bulk rock, sediment, and soils for the geological community. These materials are used globally in geochemistry, environmental, and analytical laboratories that perform bulk chemistry and/or microanalysis for instrument calibration and quality assurance testing. To answer the growing demand for higher spatial resolution and sensitivity, there is a need to create a new generation of microanalytical reference materials suitable for a variety of techniques, such as scanning electron microscopy/X-ray spectrometry (SEM/EDS), electron probe microanalysis (EPMA), laser ablation inductively coupled mass spectrometry (LA-ICP-MS), and secondary ion mass spectrometry (SIMS). As such, the microanalytical reference material (MRM) needs to be stable under the beam, be homogeneous at scales of better than 10–25 micrometers for the major to ultra-trace element level, and contain all of the analytes (elements or isotopes) of interest. Previous development of basaltic glasses intended for LA-ICP-MS has resulted in a synthetic basaltic matrix series of glasses (USGS GS-series) and a natural basalt series of glasses (BCR-1G, BHVO-2G, and NKT-1G). These materials have been useful for the LA-ICP-MS community but were not originally intended for use by the electron or ion beam community. A material developed from start to finish with intended use in multiple microanalytical instruments would be useful for inter-laboratory and inter-instrument platform comparisons. This article summarizes the experiments undertaken to produce a basalt glass reference material suitable for distribution as a multiple-technique round robin material. The goal of the analytical work presented here is to demonstrate that the elemental homogeneity of the new glass is acceptable for its use as a reference material. Because the round robin exercise is still underway, only

  20. Certification of the reference material of water content in water saturated 1-octanol by Karl Fischer coulometry, Karl Fischer volumetry and quantitative nuclear magnetic resonance.

    Science.gov (United States)

    Wang, Haifeng; Ma, Kang; Zhang, Wei; Li, Jia; Sun, Guohua; Li, Hongmei

    2012-10-15

    Certified reference materials (CRMs) of water content are widely used in the calibration and validation of Karl Fischer coulometry and volumetry. In this study, the water content of the water saturated 1-octanol (WSO) CRM was certified by Karl Fischer coulometry, volumetry and quantitative nuclear magnetic resonance (Q NMR). The water content recovery by coulometry was 99.76% with a diaphragm-less electrode and Coulomat AG anolyte. The relative bias between the coulometry and volumetry results was 0.06%. In Q NMR, the water content of WSO is traceable to the International System (SI) of units through the purity of internal standard. The relative bias of water content in WSO between Q NMR and volumetry was 0.50%. The consistency of results for these three independent methods improves the accuracy of the certification of the RM. The certified water content of the WSO CRM was 4.76% with an expanded uncertainty of 0.09%.

  1. Production and characterization of a bovine liver candidate reference material

    Science.gov (United States)

    Bianchi, S. R.; Peixoto, A. M. J.; Souza, G. B.; Tullio, R. R.; Nogueira, A. R. A.

    2016-07-01

    The preparation of a bovine liver candidate reference material and the steps are taken to confirm its homogeneity, long and short term stabilities, and consensus values are described. Details of the sample preparation and the final collaborative exercise are presented. The material elemental composition was characterized by 17 elements (As, Ca, Cd, Co, Cu, Fe, K, Mg, Mo, Mn, Na, P, Pb, Se, Sr, V, and Zn) of nutritional and toxicological significance.

  2. MICROCRM: Feasibility certification studies of microbiological reference materials

    NARCIS (Netherlands)

    Mooijman KA; Nagelkerke NJD; Demarquilly C; Lemdani M; Stewardson D; Fouweather T; Lightfoot N; Simonart T; MGB

    2004-01-01

    In 2002 feasibility certification studies were carried out on three different types of microbiological reference materials for eight different ISO and EN standard methods, related to EU water legislation (Drinking-water Directive and Bathing-water Directive). These studies were performed as part of

  3. Nanomaterials for environmental studies: classification, reference material issues, and strategies for physico-chemical characterisation.

    Science.gov (United States)

    Stone, Vicki; Nowack, Bernd; Baun, Anders; van den Brink, Nico; Kammer, Frank von der; Dusinska, Maria; Handy, Richard; Hankin, Steven; Hassellöv, Martin; Joner, Erik; Fernandes, Teresa F

    2010-03-01

    NanoImpactNet is a European Commission Framework Programme 7 (FP7) funded project that provides a forum for the discussion of current opinions on nanomaterials in relation to human and environmental issues. In September 2008, in Zurich, a NanoImpactNet environmental workshop focused on three key questions: 1. What properties should be characterised for nanomaterials used in environmental and ecotoxicology studies? 2. What reference materials should be developed for use in environmental and ecotoxicological studies? 3. Is it possible to group different nanomaterials into categories for consideration in environmental studies? Such questions have been, at least partially, addressed by other projects/workshops especially in relation to human health effects. Such projects provide a useful basis on which this workshop was based, but in this particular case these questions were reformulated in order to focus specifically on environmental studies. The workshop participants, through a series of discussion and reflection sessions, generated the conclusions listed below. The physicochemical characterisation information identified as important for environmental studies included measures of aggregation/agglomeration/dispersability, size, dissolution (solubility), surface area, surface charge, surface chemistry/composition, with the assumption that chemical composition would already be known. There is a need to have test materials for ecotoxicology, and several substances are potentially useful, including TiO(2) nanoparticles, polystyrene beads labelled with fluorescent dyes, and silver nanoparticles. Some of these test materials could then be developed into certified reference materials over time. No clear consensus was reached regarding the classification of nanomaterials into categories to aid environmental studies, except that a chemistry-based classification system was a reasonable starting point, with some modifications. It was suggested, that additional work may be

  4. The determination of water in crude oil and transformer oil reference materials.

    Science.gov (United States)

    Margolis, Sam A; Hagwood, Charles

    2003-05-01

    The measurement of the amount of water in oils is of significant economic importance to the industrial community, particularly to the electric power and crude oil industries. The amount of water in transformer oils is critical to their normal function and the amount of water in crude oils affects the cost of the crude oil at the well head, the pipeline, and the refinery. Water in oil Certified Reference Materials (CRM) are essential for the accurate calibration of instruments that are used by these industries. Three NIST Standard Reference Materials (SRMs) have been prepared for this purpose. The water in these oils has been measured by both coulometric and volumetric Karl Fischer methods. The compounds (such as sulfur compounds) that interfere with the Karl Fischer reaction (interfering substances) and inflate the values for water by also reacting with iodine have been measured coulometrically. The measured water content of Reference Material (RM) 8506a Transformer Oil is 12.1+/-1.9 mg kg(-1) (plus an additional 6.2+/-0.9 mg kg(-1) of interfering substances). The measured water content of SRM 2722 Sweet Crude Oil, is 99+/-6 mg kg(-1) (plus an additional 5+/-2 mg kg(-1) of interfering substances). The measured water content of SRM 2721 Sour Crude Oil, is 134+/-18 mg kg(-1) plus an additional 807+/-43 mg kg(-1) of interfering substances. Interlaboratory studies conducted with these oil samples (using SRM 2890, water saturated 1-octanol, as a calibrant) are reported. Some of the possible sources of bias in these measurements were identified, These include: improperly calibrated instruments, inability to measure the calibrant accurately, Karl Fischer reagent selection, and volatilization of the interfering substances in SRM 2721.

  5. Recommended reference materials for realization of physicochemical properties density

    CERN Document Server

    Herington, E F G

    1976-01-01

    This book first presents the nomenclature and units used in the determination of densities of liquids and solids, followed by a general description of the apparatus and the methods used in the measurement of density, with particular reference to the pycnometric, hydrostatic weighing, magnetic float, and temperature flotation methods. The use of water as a density reference material is then explained, focusing on the isotopic composition of Standard Mean Ocean Water (SMOW) and the absolute density of SMOW as a function of temperature. Problems due to the effect of pressure and dissolved gases o

  6. Developing Potential New Reference Materials for Light Isotopes in Foodstuffs

    Science.gov (United States)

    Frew, Russell; Van Hale, Robert; Clarke, Dianne; Abrahim, Aiman; Resch, Christian; Mayr, Leopold; Cannavan, Andrew; Gröning, Manfred

    2013-04-01

    Measurements of subtle variations in stable isotope ratios provide the means for verifying food integrity in numerous ways. Adulterants usually have different isotopic composition so their presence in a food is readily detectable. Stable isotope measurements can also be used to determine the region of production of the food. In most cases the ability of stable isotope measurements to verify, or otherwise reject, the authenticity of the food is greatly enhanced by comparison of a result to a reference database. The more high-quality data in the database, the more statistical power is afforded by the comparison. A serious weakness at present is the lack of reference materials in food matrices available to the community. Thus researchers have to rely on in-house standards for calibration and quality assurance. The result is that there are numerous datasets published that may be internally consistent but it is exceedingly difficult to combine these datasets into a cohesive database. This is particularly important for measurements of the hydrogen isotopes. Here we present a survey of the stable isotope (^2H, ^13C and ^15N) composition of 12 Reference Materials from the International Atomic Energy Agency catalogue. All but one of these materials are plant matter and have been developed as reference materials for other applications such as radionuclide or trace element measurements. Thus they have been verified as suitable materials in terms of stability and homogeneity for those tests. The purpose of this work is to ascertain if they are similarly suitable as stable isotope reference materials. The results from our survey show that there is a wide range in elemental and isotopic composition among these materials. For example, the ^15N values range from-13.5‰ to +18.6‰ and the nitrogen elemental composition range is from 0.7% to 9.7%. The ^13C values range from -20‰ to -40‰ and the carbon elemental composition ranges from 15% to 47%. We are now in the process of

  7. Size-selective poorly soluble particulate reference materials for evaluation of quantitative analytical methods.

    Science.gov (United States)

    Stefaniak, Aleksandr B; Turk, Gregory C; Dickerson, Robert M; Hoover, Mark D

    2008-07-01

    Owing to the absence of readily available certified particulate reference materials (RMs), most analytical methods used to determine particulate contaminant levels in workplace or other environments are validated using solution RMs, which do not assess the robustness of the digestion step for all forms and sizes of particles in a sample. A library of particulate RMs having a range of chemical forms and particle sizes is needed to support a shift in method evaluation strategies to include both solution and particulate RMs. In support of creating this library, we characterized bulk and physically size separated fractions of beryllium oxide (BeO) particles recovered from the machining fluid sludge of an industrial ceramic products grinding operation. Particles were large agglomerates of compact, crystalline BeO primary particles having diameters on the order of several micrometers. As expected, the particle surface area was independent of sieve size, with a range from 3.61 m(2)/g (53-63-microm fraction) to 4.82 m(2)/g (355-600-microm fraction). The density was near the theoretical value (3.01 g/cm(3)). The data support more detailed characterization of the sludge materials for use as size-selective RMs. This work illustrates an approach that can be used to develop RMs that are difficult to digest.

  8. New Filler Material for Reference Free Part Encapsulation Fixture

    Institute of Scientific and Technical Information of China (English)

    LI Bei-zhi; YANG Jian-guo; ZHOU Hu

    2002-01-01

    Reference free part encapsulation (RFPE) is a nontraditional universal fixturing technique. In this paper,new filler material-a lower melting point alloy for RFPE technique is introduced. Based on experiment, the shrinlkage and expansion rate, the effect of filler on workpiece drift and the effect of filler thickness on cutting distortion are studied. The alloy has a good mechanical and physical performance and the need of RFPE fixturing can be perfectly satisfied. The result shows that if the formula and process parameters of filler material are properly selected, it can obviously improve the quality of the workpiece, enhance the machining efficiency and reduce the manufacturing cost.

  9. 火药比容标准物质的研制%Development of Reference Material of Propellant Specific Volume

    Institute of Scientific and Technical Information of China (English)

    赵宏立; 刘来东; 靳建伟; 赵宝明; 宋长文

    2013-01-01

    A reference material, mainly composed of nitrocellulose (NC),nitroglycerine (NG), centralite and vaseline ,was developed for verifying instruments specific volume of propellant. The homogeneity of characteristic value of the reference material was tested by means of the variance analysis method, and its stability had been examined for more than one year. The reference material of propellant specific volume was determined by multi-department based on same principles, and the certified result was 627.2L/kg. The combined standard uncertainty and expanded uncertainty of standard value of reference material were also evaluated, and the expanded uncertainty was determined 9.0L/kg(k=2). The result showed that the reference material had good homogeneity and stability, its characteristic value was accurate and reliable. The reference material could meet the requirement of transferring the certified value of specific volume, calibrate and verify the instruments specific volume of propellant.%研制了以硝化棉、硝化甘油、中定剂和凡士林为主要成分的火药比容标准物质,采用方差分析方法检验了标准物质的均匀性,并进行了1a以上的稳定性考核;通过多家单位采用同一原理方法进行标准物质定值,分析评估了标准物质标准值的合成标准不确定度和扩展不确定度,得到标准比容值为627.2L/kg,扩展不确定度为9.0L/kg(k=2)。结果表明,该标准物质特性量值准确、可靠,均匀性和稳定性好,能够满足火药比容量值传递的要求,达到校准和检定火药比容测量仪的目的。

  10. Characterization of the NIST seaweed Standard Reference Material

    DEFF Research Database (Denmark)

    Outola, I.; Filliben, J.; Inn, K.g.W.

    2006-01-01

    method was found to be the most representative technique. The certified values were provided for 13 radionuclides and information values were given for 15 more radionuclides. Results for the natural decay series showed disequilibrium in both the uranium and thorium series. (c) 2006 Elsevier Ltd. All...

  11. Development and characterisation of a new line width reference material

    Science.gov (United States)

    Dai, Gaoliang; Zhu, Fan; Heidelmann, Markus; Fritz, Georg; Bayer, Thomas; Kalt, Samuel; Fluegge, Jens

    2015-11-01

    A new critical dimension (CD, often synonymously used for line width) reference material with improved vertical parallel sidewalls (IVPSs) has been developed and characterised. The sample has a size of 6 mm  ×  6 mm, consisting of 4 groups of 5  ×  5 feature patterns. Each feature pattern has a group of five reference line features with a nominal CD of 50 nm, 70 nm, 90 nm, 110 nm and 130 nm, respectively. Each feature pattern includes a pair of triangular alignment marks, applicable for precisely identifying the target measurement position, e.g. for comparison or calibration between different tools. The geometry of line features has been investigated thoroughly using a high-resolution transmission electron microscope and a CD atomic force microscope (CD-AFM). Their results indicate the high quality of the line features: the top corner radius of  strategy for the non-destructive calibration of the developed sample is introduced, which enables the application of the reference material in practice.

  12. Selective arsenic speciation analysis of human urine reference materials using gradient elution ion-exchange HPLC-ICP-MS

    DEFF Research Database (Denmark)

    Sloth, Jens Jørgen; Larsen, Erik Huusfeldt; Julshamn, K.

    2004-01-01

    Arsenic speciation analysis was performed in two human urine certified reference materials (NIES No. 18 and NIST SRM2670a) and three human urine control materials (Seronorm, Medisafe and Lyphocheck). The samples were diluted 1 + 3 prior to analysis by gradient elution anion or cation exchange high-performance...... liquid chromatography ( HPLC) coupled with inductively coupled plasma mass spectrometry (ICP-MS). Nine arsenic species, including arsenic acid, arsenous acid, monomethylarsonic acid, dimethylarsinic acid, arsenobetaine, trimethylarsine oxide, dimethylarsinoylacetic acid, trimethylarsoniopropionate...... and dimethylarsinoylethanol, were determined in the urines. Additionally, several unknown arsenicals were detected. This is the first time that dimethylarsinoylacetic acid and trimethylarsoniopropionate have been reported in human urine. The sums of the species concentrations determined by the chromatographic approaches were...

  13. Characterization of Ricin and R. communis Agglutinin Reference Materials

    Directory of Open Access Journals (Sweden)

    Sylvia Worbs

    2015-11-01

    Full Text Available Ricinus communis intoxications have been known for centuries and were attributed to the toxic protein ricin. Due to its toxicity, availability, ease of preparation, and the lack of medical countermeasures, ricin attracted interest as a potential biological warfare agent. While different technologies for ricin analysis have been established, hardly any universally agreed-upon “gold standards” are available. Expert laboratories currently use differently purified in-house materials, making any comparison of accuracy and sensitivity of different methods nearly impossible. Technically challenging is the discrimination of ricin from R. communis agglutinin (RCA120, a less toxic but highly homologous protein also contained in R. communis. Here, we established both highly pure ricin and RCA120 reference materials which were extensively characterized by gel electrophoresis, liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI MS/MS, and matrix-assisted laser desorption ionization–time of flight approaches as well as immunological and functional techniques. Purity reached >97% for ricin and >99% for RCA120. Different isoforms of ricin and RCA120 were identified unambiguously and distinguished by LC-ESI MS/MS. In terms of function, a real-time cytotoxicity assay showed that ricin is approximately 300-fold more toxic than RCA120. The highly pure ricin and RCA120 reference materials were used to conduct an international proficiency test.

  14. Characterization of Ricin and R. communis Agglutinin Reference Materials.

    Science.gov (United States)

    Worbs, Sylvia; Skiba, Martin; Söderström, Martin; Rapinoja, Marja-Leena; Zeleny, Reinhard; Russmann, Heiko; Schimmel, Heinz; Vanninen, Paula; Fredriksson, Sten-Åke; Dorner, Brigitte G

    2015-11-26

    Ricinus communis intoxications have been known for centuries and were attributed to the toxic protein ricin. Due to its toxicity, availability, ease of preparation, and the lack of medical countermeasures, ricin attracted interest as a potential biological warfare agent. While different technologies for ricin analysis have been established, hardly any universally agreed-upon "gold standards" are available. Expert laboratories currently use differently purified in-house materials, making any comparison of accuracy and sensitivity of different methods nearly impossible. Technically challenging is the discrimination of ricin from R. communis agglutinin (RCA120), a less toxic but highly homologous protein also contained in R. communis. Here, we established both highly pure ricin and RCA120 reference materials which were extensively characterized by gel electrophoresis, liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI MS/MS), and matrix-assisted laser desorption ionization-time of flight approaches as well as immunological and functional techniques. Purity reached >97% for ricin and >99% for RCA120. Different isoforms of ricin and RCA120 were identified unambiguously and distinguished by LC-ESI MS/MS. In terms of function, a real-time cytotoxicity assay showed that ricin is approximately 300-fold more toxic than RCA120. The highly pure ricin and RCA120 reference materials were used to conduct an international proficiency test.

  15. VT Certified Local Governments

    Data.gov (United States)

    Vermont Center for Geographic Information — Vermont established its Certified Local Government (CLG) program in 1985 to better help local governments integrate historic preservation concerns with planning and...

  16. Development of two fine particulate matter standard reference materials (<4 μm and <10 μm) for the determination of organic and inorganic constituents.

    Science.gov (United States)

    Schantz, Michele M; Cleveland, Danielle; Heckert, N Alan; Kucklick, John R; Leigh, Stefan D; Long, Stephen E; Lynch, Jennifer M; Murphy, Karen E; Olfaz, Rabia; Pintar, Adam L; Porter, Barbara J; Rabb, Savelas A; Vander Pol, Stacy S; Wise, Stephen A; Zeisler, Rolf

    2016-06-01

    Two new Standard Reference Materials (SRMs), SRM 2786 Fine Particulate Matter (Particulate Matter (particulate matter (PM). These materials have been characterized for the mass fractions of selected polycyclic aromatic hydrocarbons (PAHs), nitrated PAHs, brominated diphenyl ether (BDE) congeners, hexabromocyclododecane (HBCD) isomers, sugars, polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners, and inorganic constituents, as well as particle-size characteristics. These materials are the first Certified Reference Materials available to support measurements of both organic and inorganic constituents in fine PM. In addition, values for PAHs are available for RM 8785 Air Particulate Matter on Filter Media. As such, these SRMs will be useful as quality control samples for ensuring compatibility of results among PM monitoring studies and will fill a void to assess the accuracy of analytical methods used in these studies. Graphical Abstract Removal of PM from filter for the preparation of SRM 2786 Fine Particulate Matter.

  17. Production of Working Reference Materials for the Capability Evaluation Project

    Energy Technology Data Exchange (ETDEWEB)

    Phillip D. Noll, Jr.; Robert S. Marshall

    1999-03-01

    Nondestructive waste assay (NDA) methods are employed to determine the mass and activity of waste-entrained radionuclides as part of the National TRU (Trans-Uranic) Waste Characterization Program. In support of this program the Idaho National Engineering and Environmental Laboratory Mixed Waste Focus Area developed a plan to acquire capability/performance data on systems proposed for NDA purposes. The Capability Evaluation Project (CEP) was designed to evaluate the NDA systems of commercial contractors by subjecting all participants to identical tests involving 55 gallon drum surrogates containing known quantities and distributions of radioactive materials in the form of sealed-source standards, referred to as working reference materials (WRMs). Although numerous Pu WRMs already exist, the CEP WRM set allows for the evaluation of the capability and performance of systems with respect to waste types/configurations which contain increased amounts of {sup 241}Am relative to weapons grade Pu, waste that is dominantly {sup 241}Am, as well as wastes containing various proportions of depleted uranium. The CEP WRMs consist of a special mixture of PuO{sub 2}/AmO{sub 2} (IAP) and diatomaceous earth (DE) or depleted uranium (DU) oxide and DE and were fabricated at Los Alamos National Laboratory. The IAP WRMS are contained inside a pair of welded inner and outer stainless steel containers. The DU WRMs are singly contained within a stainless steel container equivalent to the outer container of the IAP standards. This report gives a general overview and discussion relating to the production and certification of the CEP WRMs.

  18. Preparation, characterization and certification of uranium isotope reference materials; Preparacao, Caracterizacao e certificacao de materiais de referencia isotopicos de uranio

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira Junior, Olivio Pereira de

    2006-07-01

    This work describes the preparation, characterization and certification of a set of uranium isotope reference materials ranging from 0.5 to 20.0 % of {sup 235}U in mass. The most important concepts of metrology in chemical measurements were applied so that the certified quantities in these materials could be directly traceable to the International System of Units (SI). As a consequence of this approach, these materials can be used in the instruments calibration, estimation of measurement uncertainty, method validation, assessment of performance of analysts, quality control routines and interlaboratory comparison programmes. The most advanced methods and techniques in mass spectrometry, that is, gas source mass spectrometry (GSMS), thermal ionisation mass spectrometry (TIMS) and inductively coupled plasma mass spectrometry (ICPMS) were investigated to identify which are the dominant components in the uncertainty and to quantify its contribution to the final value of the measurement uncertainty of the isotopic ratio. The results obtained were then compared to verify which are the methods and techniques associated to the lowest measurement uncertainty values. The isotope amount ratio n({sup 235}U)/n({sup 238}U) was certified in the materials produced to expanded uncertainties ranging from 0.02 to 0.10 % and the ratios n({sup 234}U)/n({sup 238}U) and n({sup 236}U)/n({sup 238}U), to uncertainties ranging from 0.03 to 2.20 %. These values fully comply to the requirements of the isotopic characterization of nuclear fuel as well as the analysis of environmental samples for nuclear safeguards. (author)

  19. Development of urine standard reference materials for metabolites of organic chemicals including polycyclic aromatic hydrocarbons, phthalates, phenols, parabens, and volatile organic compounds.

    Science.gov (United States)

    Schantz, Michele M; Benner, Bruce A; Heckert, N Alan; Sander, Lane C; Sharpless, Katherine E; Vander Pol, Stacy S; Vasquez, Y; Villegas, M; Wise, Stephen A; Alwis, K Udeni; Blount, Benjamin C; Calafat, Antonia M; Li, Zheng; Silva, Manori J; Ye, Xiaoyun; Gaudreau, Éric; Patterson, Donald G; Sjödin, Andreas

    2015-04-01

    Two new Standard Reference Materials (SRMs), SRM 3672 Organic Contaminants in Smokers' Urine (Frozen) and SRM 3673 Organic Contaminants in Non-Smokers' Urine (Frozen), have been developed in support of studies for assessment of human exposure to select organic environmental contaminants. Collaborations among three organizations resulted in certified values for 11 hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and reference values for 11 phthalate metabolites, 8 environmental phenols and parabens, and 24 volatile organic compound (VOC) metabolites. Reference values are also available for creatinine and the free forms of caffeine, theobromine, ibuprofen, nicotine, cotinine, and 3-hydroxycotinine. These are the first urine Certified Reference Materials characterized for metabolites of organic environmental contaminants. Noteworthy, the mass fractions of the environmental organic contaminants in the two SRMs are within the ranges reported in population survey studies such as the National Health and Nutrition Examination Survey (NHANES) and the Canadian Health Measures Survey (CHMS). These SRMs will be useful as quality control samples for ensuring compatibility of results among population survey studies and will fill a void to assess the accuracy of analytical methods used in studies monitoring human exposure to these organic environmental contaminants.

  20. Quantitative micro x-ray fluorescence analyses without reference standard material; Referenzprobenfreie quantitative Mikro-Roentgenfluoreszenzanalyse

    Energy Technology Data Exchange (ETDEWEB)

    Wolff, Timo

    2009-07-15

    X-ray fluorescence analysis (XRF) is a standard method for non-destructive investigations. Due to the development of polycapillary optics and SDDdetectors requiring no cooling with liquid nitrogen, XRF becomes a suitable method for a large number of applications, e. g. for the analysis of objects in arts and archaeology. Spectrometers developed for those purposes allow investigations outside of laboratories und provide excitation areas with diameters of 10-70 {mu}m. In most applications, quantification of XRF data is realized by the usage of standard reference materials. Due to absorption processes in the samples the accuracy of the results depends strongly on the similarity of the sample and the reference standard. In cases where no suitable references are available, quantification can be done based on the ''fundamental parameter (fp) method''. This quantification procedure is based on a set of equations describing the fluorescence production and detection mathematical. The cross sections for the interaction of x-rays with matter can be taken from different databases. During an iteration process the element concentrations can be determined. Quantitative XRF based on fundamental parameters requires an accurate knowledge of the excitation spectrum. In case of a conventional setup this spectrum is given by the X-ray tube spectrum and can be calculated. The use of polycapillary optics in micro-XRF spectrometers changes the spectral distribution of the excitation radiation. For this reason it is necessary to access the transmission function of the used optic. The aim of this work is to find a procedure to describe this function for routine quantification based on fundamental parameters. Most of the measurements have been carried out using a commercial spectrometer developed for applications in arts and archaeology. On the one hand the parameters of the lens, used in the spectrometer, have been investigated by different experimental characterization

  1. k{sub 0}-NAA quality assessment in an Algerian laboratory by analysis of SMELS and four IAEA reference materials using Es-Salam research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Hamidatou, L.A., E-mail: lylia.h@hotmail.fr [Nuclear Reseach Center of Birine, P.O. Box 180 Ain Oussera, 17200 Djelfa (Algeria); Dekar, S.; Boukari, S. [Department of physics, Ferhat Abbes University, 19000 Setif (Algeria)

    2012-08-01

    Different types of synthetic multi-element standard material (SMELS) and four IAEA reference materials, 140, Sl-1, Soil-7 and Lichen-336 were analyzed for validation and QC/QA of the k{sub 0}-standardised Neutron Activation Analysis (k{sub 0}-NAA). The samples of SMELS and RMs were irradiated at Es-Salam research reactor and measured on an absolutely calibrated HPGe detector with 35% relative efficiency connected to a Canberra Genie 2k inspector. Concentrations of 33 elements such as As, Au, Ba, Br, Ca, Ce, Co, Cr, Cs, Eu, Fe, Hf, In, K, La, Mn, Mo, Na, Nd, Rb, Sb, Sc, Se, Sm, Sr, Ta, Tb, Th, Tm, U, Yb, Zn, and Zr were determined in SMELS and RMs. The analytical results agreed well with the assigned values of SMELS and certified values of RMs. In the case of RMs, concentrations of a few elements, whose certified values are not available, could be determined. The comparison between experimental values and assigned/certified data for SMELS and RMs was made by means of the results from Relative Bias, Z-score and U-score. The relatives bias of the elements determined in SMELS with respect to the assigned values were all within{+-}4.6%. For RMs with respect to certified values were within{+-}10% except for few elements for which RB varied from -28.6% to +12.8%. The Z-score values at 95% confidence level for most of the elements in both the materials were within {+-}1. The U-scores for most of the elements were lower than 1.

  2. 40 CFR 1068.95 - What materials does this part reference?

    Science.gov (United States)

    2010-07-01

    ... material from the Society of Automotive Engineers that we have incorporated by reference. The first column... reference it. Anyone may purchase copies of these materials from the Society of Automotive Engineers,...

  3. Metallurgical and chemical characterization of copper alloy reference materials within laser ablation inductively coupled plasma mass spectrometry: Method development for minimally-invasive analysis of ancient bronze objects

    Energy Technology Data Exchange (ETDEWEB)

    Walaszek, Damian, E-mail: damian.walaszek@empa.ch [Laboratory for Analytical Chemistry, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, CH-8600 Dübendorf (Switzerland); University of Warsaw, Faculty of Chemistry, Pasteura 1, 02-093 Warsaw (Poland); Senn, Marianne [Laboratory for Analytical Chemistry, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, CH-8600 Dübendorf (Switzerland); Faller, Markus [Laboratory for Jointing Technology and Corrosion, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, CH-8600 Dübendorf (Switzerland); Philippe, Laetitia [Laboratory for Mechanics of Materials and Nanostructures, Swiss Federal Laboratories for Materials Science and Technology, Feuerwerkstrasse 39, CH-3602 Thun (Switzerland); Wagner, Barbara; Bulska, Ewa [University of Warsaw, Faculty of Chemistry, Pasteura 1, 02-093 Warsaw (Poland); Ulrich, Andrea [Laboratory for Analytical Chemistry, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, CH-8600 Dübendorf (Switzerland)

    2013-01-01

    The chemical composition of ancient metal objects provides important information for manufacturing studies and authenticity verification of ancient copper or bronze artifacts. Non- or minimal-destructive analytical methods are preferred to mitigate visible damage. Laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) enables the determination of major elements as well as impurities down to lower ppm-levels, however, accuracy and precision of analysis strongly depend on the homogeneity of reference materials used for calibration. Moreover, appropriate analytical procedures are required e.g. in terms of ablation strategies (scan mode, spot size, etc.). This study reviews available copper alloy (certified) reference materials — (C)RMs from different sources and contributes new metallurgical data on homogeneity and spatial elemental distribution. Investigations of the standards were performed by optical and scanning electron microscopy with X-ray spectrometry (SEM-EDX) for the following copper alloy and bronze (certified) reference materials: NIST 454, BAM 374, BAM 211, BAM 227, BAM 374, BAM 378, BAS 50.01-2, BAS 50.03-4, and BAS 50.04-4. Additionally, the influence of inhomogeneities on different ablation and calibration strategies is evaluated to define an optimum analytical strategy in terms of line scan versus single spot ablation, variation of spot size, selection of the most appropriate RMs or minimum number of calibration reference materials. - Highlights: ► New metallographic data for copper alloy reference materials are provided. ► Influence of RMs homogeneity on quality of LA-ICPMS analysis was evaluated. ► Ablation and calibration strategies were critically discussed. ► An LA-ICPMS method is proposed for analyzing most typical ancient copper alloys.

  4. Development of working reference materials for clinical virology.

    Science.gov (United States)

    Fryer, Jacqueline F; Baylis, Sally A; Gottlieb, Anna L; Ferguson, Morag; Vincini, Giuseppe A; Bevan, Valerie M; Carman, William F; Minor, Philip D

    2008-12-01

    Nucleic acid amplification technique (NAT)-based assays are replacing traditional diagnostic methods in clinical laboratories. However, many of these assays are developed in-house and the lack of standardised reference materials has hindered assay implementation and control. Consequently, in the UK, the Clinical Virology Network (CVN), the National Institute for Biological Standards and Control (NIBSC), and the Health Protection Agency (HPA), are working in collaboration to develop working standards or 'run controls' for diagnostic NAT-based assays, particularly real-time PCR. These run controls are intended for use in microbiology laboratories and are designed to be extracted and amplified in the same way as clinical samples and included in each assay run. The aim is to enable clinical laboratories to continuously monitor the performance of their diagnostic NAT assays on a run-by-run basis allowing inter-laboratory comparisons, and ultimately improving the consistency of results. At present, eight candidate run controls representing clinically relevant viral targets have been prepared for evaluation by CVN laboratories. Data have been returned on the performance of each run control in routine diagnostic assays. Preliminary results presented here indicate a high level of variability in intra- and inter-assay detection of these targets, highlighting the need for standardisation of assays within molecular diagnostics.

  5. LA-ICP-MS of magnetite: Methods and reference materials

    Science.gov (United States)

    Nadoll, P.; Koenig, A.E.

    2011-01-01

    Magnetite (Fe3O4) is a common accessory mineral in many geologic settings. Its variable geochemistry makes it a powerful petrogenetic indicator. Electron microprobe (EMPA) analyses are commonly used to examine major and minor element contents in magnetite. Laser ablation ICP-MS (LA-ICP-MS) is applicable to trace element analyses of magnetite but has not been widely employed to examine compositional variations. We tested the applicability of the NIST SRM 610, the USGS GSE-1G, and the NIST SRM 2782 reference materials (RMs) as external standards and developed a reliable method for LA-ICP-MS analysis of magnetite. LA-ICP-MS analyses were carried out on well characterized magnetite samples with a 193 nm, Excimer, ArF LA system. Although matrix-matched RMs are sometimes important for calibration and normalization of LA-ICP-MS data, we demonstrate that glass RMs can produce accurate results for LA-ICP-MS analyses of magnetite. Cross-comparison between the NIST SRM 610 and USGS GSE-1G indicates good agreement for magnetite minor and trace element data calibrated with either of these RMs. Many elements show a sufficiently good match between the LA-ICP-MS and the EMPA data; for example, Ti and V show a close to linear relationship with correlation coefficients, R2 of 0.79 and 0.85 respectively. ?? 2011 The Royal Society of Chemistry.

  6. FDA Certified Mammography Facilities

    Science.gov (United States)

    ... Products Radiation-Emitting Products Home Radiation-Emitting Products Mammography Quality Standards Act and Program Consumer Information (MQSA) ... it Email Print This list of FDA Certified Mammography Facilities is updated weekly. If you click on ...

  7. ENERGY STAR Certified Furnaces

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 4.0 ENERGY STAR Program Requirements for Furnaces that are effective as of February 1,...

  8. ENERGY STAR Certified Boilers

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 3.0 ENERGY STAR Program Requirements for Boilers that are effective as of October 1,...

  9. Certified Electronics Recyclers

    Science.gov (United States)

    Learn how EPA encourages all electronics recyclers become certified by demonstrating to an accredited, independent third-party auditor and that they meet specific standards to safely recycle and manage electronics.

  10. ENERGY STAR Certified Computers

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 6.1 ENERGY STAR Program Requirements for Computers that are effective as of June 2, 2014....

  11. Reference Materials in LIS Instruction: A Delphi Study

    Science.gov (United States)

    Rabina, Debbie

    2013-01-01

    This paper presents the results of a Delphi study conducted over a two-month period in 2011. The purpose of the study was to identify reference sources that should be covered in basic reference courses taught in LIS programs in the United States. The Delphi method was selected for its appropriateness in soliciting expert opinions and assessing the…

  12. 10 CFR 431.443 - Materials incorporated by reference.

    Science.gov (United States)

    2010-01-01

    ... reference. (a) General. The Department incorporates by reference the following standards into Subpart X of... Test Methods for Single- and Three-Phase Small Motors, IBR approved for § 431.444. (2) (c) IEEE...-1331, 1-800-678-IEEE (4333), or go to http://www.ieee.org/web/publications/home/index.html. (1)...

  13. Certified randomness in quantum physics

    Science.gov (United States)

    Acín, Antonio; Masanes, Lluis

    2016-12-01

    The concept of randomness plays an important part in many disciplines. On the one hand, the question of whether random processes exist is fundamental for our understanding of nature. On the other, randomness is a resource for cryptography, algorithms and simulations. Standard methods for generating randomness rely on assumptions about the devices that are often not valid in practice. However, quantum technologies enable new methods for generating certified randomness, based on the violation of Bell inequalities. These methods are referred to as device-independent because they do not rely on any modelling of the devices. Here we review efforts to design device-independent randomness generators and the associated challenges.

  14. Certified randomness in quantum physics.

    Science.gov (United States)

    Acín, Antonio; Masanes, Lluis

    2016-12-07

    The concept of randomness plays an important part in many disciplines. On the one hand, the question of whether random processes exist is fundamental for our understanding of nature. On the other, randomness is a resource for cryptography, algorithms and simulations. Standard methods for generating randomness rely on assumptions about the devices that are often not valid in practice. However, quantum technologies enable new methods for generating certified randomness, based on the violation of Bell inequalities. These methods are referred to as device-independent because they do not rely on any modelling of the devices. Here we review efforts to design device-independent randomness generators and the associated challenges.

  15. [Study of reference material for excitation spectrum wavelength calibration of fluorescence spectrophotometer].

    Science.gov (United States)

    Chen, Xiao-bo; Kang, Dong-guo; Zhao, Cheng-yi; Li, Song; Wu, Zheng-long; Ma, Hui; Liu, Zhong-min; Zheng, Zhe

    2005-07-01

    A reference material used for wavelength calibration of fluorescence spectrophotometer was found. The holmium doped oxide reference material GBW(E) 130112 is a kind of standard reference material for absorption spectrophotometer. It can emit 547.7 nm fluorescence when excited by xenon lamp light. The excitation spectrum of 547.7 nm fluorescence was measured. It was found that the measured peaks of excitation spectrum are positioned at 333.56, 360.43 and 418.39 nm, respectively, which are coincident with the true values 333.8, 360.9 and 418.5 nm of reference material certification. It was illustrated that the holmium doped oxide reference material GBW(E)130112 could be used as reference material for the excitation wavelength calibration of the fluorescence spectrophotometer. Its property could be enhanced very much if high luminescent efficiency material is selected as rare earth ion doped matrix, and the purity is enhanced to reduce the cross relaxation.

  16. A new series of uranium isotope reference materials for investigating the linearity of secondary electron multipliers in isotope mass spectrometry

    Science.gov (United States)

    Richter, S.; Alonso, A.; Aregbe, Y.; Eykens, R.; Kehoe, F.; Kühn, He; Kivel, N.; Verbruggen, A.; Wellum, R.; Taylor, P. D. P.

    2009-04-01

    A new series of gravimetrically prepared uranium isotope reference materials, the so-called IRMM-074 series, with the n(235U)/n(238U) isotope ratio held constant at unity and the n(233U)/n(238U) isotope ratios varying from 1.0 to 10-6 has been prepared and certified. This series is suited for calibration of secondary electron multipliers used widely in isotope mass spectrometry, in particular for techniques such as thermal ionization mass spectrometry (TIMS), inductively coupled plasma mass spectrometry (ICPMS), accelerator mass spectrometry (AMS) and resonance ionization mass spectrometry (RIMS). The new IRMM-074 was prepared as a replacement for the already exhausted IRMM-072 predecessor series. Uranium materials with high isotopic enrichments of 233U, 235U and 238U were purified using identical methods involving separation on anion and cation column followed by a precipitation as peroxide. The oxides were calcined to convert them to U3O8 simultaneously, in an oven installed in a glove-box that provided a controlled low-humidity environment. The oxides of 235U and 238U were weighed and mixed with a mole ratio n(235U)/n(238U) = 1.0 and then dissolved. The 233U oxide was dissolved to form a separate solution with the same concentration and 6rom this primary solution three dilutions were made by weighing. A weighed amount of the n(235U)/n(238U) solution and weighed amounts of the 233U solutions were mixed in various proportions in order to achieve n(233U)/n(238U) isotope ratios varying from 1.0 to 10-6. The methods for the preparation, the mixing and the mixing calculations are described. The expanded uncertainties (coverage factor k = 2) of the certified isotope ratios for the IRMM-074 series are 0.015% for the n(235U)/n(238U) ratio and 0.025% for the n(233U)/n(238U) ratios, which constitutes an improvement compared to those of the predecessor IRMM-072 series. In addition, recent observations regarding the linearity response of secondary electron multipliers (SEMs

  17. Determination of selected oxygenated polycyclic aromatic hydrocarbons (oxy-PAHs) in diesel and air particulate matter standard reference materials (SRMs).

    Science.gov (United States)

    Nocun, Margarete S; Schantz, Michele M

    2013-06-01

    Oxygenated polycyclic aromatic hydrocarbons (oxy-PAHs) have recently received much attention in discussions regarding the negative impacts of particulate matter (PM) on human health and the environment. The National Institute of Standards and Technology provides several environmental matrix standard reference materials (SRMs) with certified and reference values for polycyclic aromatic hydrocarbons (PAHs) and nitrated PAHs. In this study, the concentrations of oxygenated PAHs are determined in three air PM SRMs (1649b, 1648a, and 2786) and three diesel PM SRMs (1650b, 2975, and 1975) using two independent gas chromatography-mass spectrometry methods. Concentrations of oxy-PAHs were at the milligrams per kilogram level with higher overall concentrations in diesel PM (up to 50 mg/kg for 9,10-anthraquinone). One of the highest oxy-PAH concentrations (up to 5 mg/kg) measured in the air particulate SRMs was for 7,12-benz[a]anthracenquinone. These results suggest that oxygenated PAHs should not be neglected in the analysis of PM as their concentrations can be as high as those of some PAHs and are one to two orders of magnitude higher than those for nitro-PAHs.

  18. 10 CFR 431.133 - Materials incorporated by reference.

    Science.gov (United States)

    2010-01-01

    ...-Conditioning and Refrigeration Institute (ARI) Standard 810-2003, “Performance Rating of Automatic Commercial..., Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard 29-1988 (RA 2005), “Methods of Testing Automatic... incorporated by reference are available for inspection at: (i) National Archives and Records...

  19. Recommended reference materials for realization of physicochemical properties pressure-volume-temperature relationships

    CERN Document Server

    Herington, E F G

    1977-01-01

    Recommended Reference Materials for Realization of Physicochemical Properties presents recommendations of reference materials for use in measurements involving physicochemical properties, namely, vapor pressure; liquid-vapor critical temperature and critical pressure; orthobaric volumes of liquid and vapor; pressure-volume-temperature properties of the unsaturated vapor or gas; and pressure-volume-temperature properties of the compressed liquid. This monograph focuses on reference materials for vapor pressures at temperatures up to 770 K, as well as critical temperatures and critical pressures

  20. USGS Reference Materials Program: Serving the Needs of the Global Analytical Community

    Science.gov (United States)

    Wolf, Ruth E.; Wilson, Stephen A.

    2007-01-01

    Every year in the United States, millions of measurements are made on the chemical composition of items that affect us on a daily basis. The accuracy of these measurements is routinely determined by the analysis of appropriate reference materials. In the field of earth science, reference materials are particularly important because they help us develop a better understanding of the processes that have shaped, and continue to shape the world around us. USGS reference materials are distributed internationally to organizations involved in geochemical and environmental analysis, instrumentation and methods development, and industrial research and quality assurance. Reference materials are widely used in the development and validation of geochemical models used by the USGS.

  1. Alternative buffer material. Status of the ongoing laboratory investigation of reference materials and test package 1

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Daniel [Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden); Dueck, Ann; Nilsson, Ulf; Olsson, Siv; Sanden, Torbjoern [Clay Technology AB, Lund (Sweden); Lydmark, Sara; Jaegerwall, Sara; Pedersen, Karsten [Microbial Analytics Sweden AB, Moelnlycke (Sweden); Hansen, Staffan [LTH Lund Univ., Lund (Sweden)

    2011-07-15

    Bentonite clay is part of the Swedish KBS-3 design of final repositories for high level radioactive waste. Wyoming bentonite with the commercial name MX-80 (American Colloid Co) has long been the reference for buffer material in the KBS-3 concept. Extending the knowledge base of alternative buffer materials will make it possible to optimize regarding safety, availability and cost. For this reason the field experiment Alternative Buffer Material (ABM) was started at Aespoe Hard Rock Laboratory during 2006. The experiment includes three medium-scale test packages, each consisting of a central steel tube with heaters, and a buffer of compacted clay. Eleven different clays were chosen for the buffers to examine effects of smectite content, interlayer cations and overall iron content. Also bentonite pellets with and without additional quartz are being tested. The buffer in package 1 had been subjected to wetting by formation water and heating for more than two years (at 130 deg C for {approx} 1 year) when it was retrieved and analyzed. The main purposes of the project were to characterise the clays with respect to hydro-mechanical properties, mineralogy and chemical composition and to identify any differences in behaviour or long term stability. The diversity of clays and the heater of steel also make the experiment suitable for studies of iron-bentonite interactions. This report concerns the work accomplished up to now and is not to be treated as any final report of the project.

  2. Determination of water in NIST reference material for mineral oils

    Science.gov (United States)

    Cedergren; Nordmark

    2000-07-15

    The accuracy of the reference concentrations of moisture in electrical insulating oil RM 8506 and lubricating oil RM 8507 (both of mineral type) and specified by the National Institute of Standards and Technology (NIST) as containing 39.7 and 76.8 ppm (w/w) water, respectively, has recently been the subject of debate in this journal. To shed some further light on this controversy, we report in this correspondence results for these oils obtained by two additional methods, one based on specially designed reagents for diaphragm-free Karl Fischer (KF) coulometry and the other based on the concept of stripping at elevated temperature/continuous KF coulometry. A positive interference effect was shown to take place for RM 8506 when the direct coulometric method was used. If the results are corrected for this, the values including six different procedures varied in the range 13.5-15.6 ppm (w/w). For RM 8507, all values were between 42.5 and 47.2 ppm (w/w), which means that the values recommended by NIST for both reference oils using volumetric titration are about twice as high as those obtained with the other techniques. A possible explanation for this discrepancy is presented.

  3. 10 CFR 435.3 - Material incorporated by reference.

    Science.gov (United States)

    2010-01-01

    ... Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435... this material by the standard-setting organization will not affect the DOE building energy...

  4. [Latin American regional reference materials for porcine heparin and bovine heparin].

    Science.gov (United States)

    Albertengo, M E; Cinto, R O; Araldi, H T; Vernengo, M J

    1990-02-01

    In agreement with the Regional Programme of Reference Materials of the Panamerican Health Organization the Instituto Nacional de Farmacología y Bromatología of Buenos Aires designed a study for the calibration of a Reference Material for Heparin, porcine, mucosal and a Reference Material for Heparin, bovine, mucosal. The assay methods used in this study were those described in the United States Pharmacopeia XXI Ed and British Pharmacopoeia 1980, Addendum 1983. The overall combined potency estimates of both heparin in preparations relative to 4th Int.St. was 1633.83 UI/ampoule (95% confidence limits 1609.70-1657.96 UI/ampoule) for porcine heparin and 1332.31 UI/ampoule (95% confidence limits, 1302.31-1361.77 UI/ampoule) for bovine heparin. The assigned unitage was 1630 UI/ampoule for the porcine Reference Material and 1330 UI/ampoule for the bovine Reference Material.

  5. Advance in Developing Genetically Modified Plant Reference Material%转基因植物标准物质研究进展

    Institute of Scientific and Technical Information of China (English)

    董莲华; 赵正宜; 李亮; 隋志伟; 王晶

    2012-01-01

    转基因产品的安全性一直都备受关注,因此转基因产品的定性、定量检测越来越重要,而转基因标准物质的使用是转基因产品检测结果有效和可比的重要保证.本文针对国内外转基因植物标准物质的研究现状及相关技术进行综述,重点介绍了转基因植物标准物质的种类、转基因标准物质定值技术,分析了转基因标准物质研制过程中的关键点.更重要的是综述并提出了质粒DNA分子标准物质的定值模式,包括如何合理评价质粒分子可替代性问题,此外还总结了目前国外转基因标准物质的种类,目的是为我国转基因植物标准物质研制和相关研究提供有价值的参考.%In the p ast two decades, many countries have been paying more attention to safety of genetically modified (GM) product, and thus, qualitative and quantitative test of GM products become more and more important. The test result can be more comparable and reliable by using GM reference material. This paper reviews the research progress of GM reference material and related techniques: it introduces the variety of GM reference material and techniques of value assignment for GM reference material, and also evaluates the key procedures in developing GM reference material. More importantly, it is concluded that how to assign the reference value for the plasmid reference material including the commutability between the plasmid and genomic DNA. Additionally, it summarizes the current international GM certified reference material. This aims to provide some valuable reference for developing GM reference material in China.

  6. ENERGY STAR Certified Displays - Deprecated

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset is up-to-date but newer better data can be retrieved at: https://data.energystar.gov/dataset/ENERGY-STAR-Certified-Displays/xsyb-v8gs Certified models...

  7. Evolutionary design of bone scaffolds with reference to material selection.

    Science.gov (United States)

    Heljak, M K; Swięszkowski, W; Lam, C X F; Hutmacher, D W; Kurzydłowski, K J

    2012-01-01

    The favourable scaffold for bone tissue engineering should have desired characteristic features, such as adequate mechanical strength and three-dimensional open porosity, which guarantee a suitable environment for tissue regeneration. In fact, the design of such complex structures like bone scaffolds is a challenge for investigators. One of the aims is to achieve the best possible mechanical strength-degradation rate ratio. In this paper we attempt to use numerical modelling to evaluate material properties for designing bone tissue engineering scaffold fabricated via the fused deposition modelling technique. For our studies the standard genetic algorithm was used, which is an efficient method of discrete optimization. For the fused deposition modelling scaffold, each individual strut is scrutinized for its role in the architecture and structural support it provides for the scaffold, and its contribution to the overall scaffold was studied. The goal of the study was to create a numerical tool that could help to acquire the desired behaviour of tissue engineered scaffolds and our results showed that this could be achieved efficiently by using different materials for individual struts. To represent a great number of ways in which scaffold mechanical function loss could proceed, the exemplary set of different desirable scaffold stiffness loss function was chosen.

  8. Difficulties of Alternatively Certified Teachers

    Science.gov (United States)

    Schonfeld, Irvin Sam; Feinman, Samantha J.

    2012-01-01

    This daily diary study followed, over a 2-week period, 252 beginning New York City public school teachers. Seventy percent were alternatively certified (New York City Teaching Fellows) and the rest, traditionally certified teachers. Alternatively certified teachers were more likely to experience stressors such as violent incidents and classroom…

  9. Development of an orange juice in-house reference material and its application to guarantee the quality of vitamin C determination in fruits, juices and fruit pulps.

    Science.gov (United States)

    Valente, A; Sanches-Silva, A; Albuquerque, T G; Costa, H S

    2014-07-01

    Reference materials are useful for the quality control of analytical procedures and to evaluate the performance of laboratories. There are few and expensive certified reference materials commercially available for vitamin C or ascorbic acid analysis in food matrices. In this study, the preparation and the suitability assessment of an orange juice in-house reference material (RM) for vitamin C analysis in fruits, juices and in fruit pulps is described. This RM was used for the development and full validation of an HPLC method. The results showed excellent linearity (r(2)=0.9995), good accuracy (96.6-97.3%) and precision, as relative standard deviation, ranged from 0.70% to 3.67%. The in-house RM was homogenous and stable at storage conditions (-80°C) during 12 months. According to our results, this in-house RM is an excellent tool to use in quality control and method verification purposes for vitamin C analysis of fruits, juices and fruit pulps matrices. Furthermore, a stabilization solution with perchloric and metaphosphoric acids was developed which prevents degradation of ascorbic acid for a period of 12 months at -80°C.

  10. Embrapa's experience in the production and development of agriculture reference materials

    Science.gov (United States)

    Nogueira, A. R. A.; Souza, G. B.; Bossu, C. M.; Bianchi, S. R.; Verhalen, T. R.; Silva, P. T.; Peixoto, A. A. J.; Silva, C. S.

    2016-07-01

    The main challenge of Embrapa is to develop a model of genuine Brazilian tropical agriculture and livestock. To get this task, the quality of laboratories results is mandatory, increasing the demand for reference materials. Projects were proposed to produce reference materials to support the national agriculture laboratories and consolidate a network able to perform reliable and reproducible analytical testing laboratory within the internationally standards required. Reference materials were produced and available to interested laboratories and collaborative tests were conducted to obtain consensus values. The results and statistical evaluations were performed with the use of software developed by Embrapa Pecuaria Sudeste.

  11. Determination and Certification of Multielements in 6 Biological Reference Materials by NAA

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>Food safety has been a problem of global concern. The insufficient availability of certificated reference materials (CRM) used for food analysis has resulted in a lack of internal quality control in food

  12. Evaluation of Botanical Reference Materials for the Determination of Vanadium in Biological Samples

    DEFF Research Database (Denmark)

    Heydorn, Kaj; Damsgaard, Else

    1982-01-01

    Three botanical reference materials prepared by the National Bureau of Standards have been studied by neutron activation analysis to evaluate their suitability with respect to the determination of vanadium in biological samples. Various decomposition methods were applied in connection with chemic....... A reference value of 1.15 mg/kg of this material is recommended, based on results from 3 different methods. All three materials are preferable to SRM 1571 Orchard Leaves, while Bowen's Kale remains the material of choice because of its lower concentration....

  13. 异辛烷中马拉硫磷溶液标准物质的研制及不确定度分析%Development and Uncertainty Malathion Solution Reference Material Analysis Isooctane

    Institute of Scientific and Technical Information of China (English)

    王帆寿; 毛沅文

    2016-01-01

    采用重量-容量法研制了异辛烷中马拉硫磷溶液标准物质,通过气相色谱法(NPD检测器)考察了其均匀性、稳定性并对定值方法的不确定度进行了评定。实验结果表明,研制的异辛烷中马拉硫磷溶液标准物质符合国家二级有证标准物质技术要求,定值结果为:(10.0±0.2)g/mL(U=95%),稳定期为12个月,该标准物质已获批成为国家二级标准物质GBW(E)130473。%Development of malathion in isooctane certified reference material was prepared by the gravity-volume method.After the tests of homogeneity and stability by gas chromatography(NPD detector)and method of valuation of the uncertainty was evaluated. Experimental results show that the development of the malathion in isooctane reference material accords to the technical requirements of national secondary certified reference material,the certified result is:[10.0±0.2]g/mL(U=95%),it is found to be stable at least 12 months.It has been approved as the national standard material GBW(E)130473.

  14. REFERENCE MATERIALS

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Potala PalaceConstruction of the Potala Palace began in the mid-7th century for the Tubo King Songtsan Gambo to greet his Han wife, Princess Wencheng. It comprised 999 rooms then, plus one built atop the Red Hill, which, said to have 1,000 rooms, was later destroyed by thunderbolts and wars. What we see today is a structure built during the 17th century.In the mid-17th century, the White House was added to the Potala Palace, which spread along the Red Hill in Lhasa.The palace is a structure of clay, wood and stone. The palace was the residence of the Dalai Lama of various generations. Beginning with the period of the 5th Dalai Lama, major religious and political ceremonies were held there.The palace covers a total area of 360,000 square meters, with major building rising 117 meters high in 13 floors, and extends some 360 meters from east to west.From 1989 to 1994, the State earmarked some 55 million Yuan and large quantities of gold and silver to repair the palace.In December 1994, the palace found its w

  15. Quantitative analysis of trace elements in environmental powders with laser ablation inductively coupled mass spectrometry using non-sample-corresponding reference materials for signal evaluation

    Science.gov (United States)

    Bauer, Gerald; Limbeck, Andreas

    2015-11-01

    Laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS) is an attractive alternative to traditional procedures for the analysis of environmental samples (i.e., conventional liquid measurement after sample digestion). However, for accurate quantification, certified reference materials (CRM) are necessary which match the composition of the sample and include all elements of interest at the required concentration levels. The limited availability of appropriate CRMs hampers therefore substantial application. In this work, an LA-ICP-MS procedure allowing for accurate determination of trace element contents in powdered environmental samples is presented. For LA-ICP-MS analysis, the samples are mixed with an internal standard (silver oxide) and a binder (sodium tetra borate) and subsequently pressed to pellets. Quantification is accomplished using a calibration function determined using CRMs with varying matrix composition and analyte content, pre-treated and measured in the same way as the samples. With this approach, matrix-induced ablation differences resulting from varying physical/chemical properties of the individual CRMs could be compensated. Furthermore, ICP-related matrix-effects could be minimized using collision/reaction cell technology. Applicability of the procedure has been demonstrated by assessment of Cd, Cu, Ni, and Zn in four different environmental CRMs (NIST SRM1648a (urban particulate matter), NIST SRM2709 (San Joaquin Soil), BCR144 (sewage sludge), and BCR723 (road dust)). Signal evaluation was performed by alternative use of three CRMs for calculation of the calibration function whereas the remaining fourth CRM acted as unknown sample, resulting in a good agreement between measured and certified values for all elements and reference materials.

  16. Certificate of Analysis, Standard Reference Material® 1849, Infant/Adult Nutritional Formula

    Science.gov (United States)

    Standard Reference material (SRM) 1849 is intended primarily for validation of methods for determining proximates, fatty acids, vitamins, elements and nucleotides in infant and adult nutritional formulas and similar materials. This SRM can also be used for quality assurance when assigning values to ...

  17. Determination of perfluorinated alkyl acid concnetrations in biological standard reference materials

    NARCIS (Netherlands)

    Reiner, J.L.; O'Connell, S.G.; Butt, C.M.; Kwadijk, C.J.A.F.

    2012-01-01

    Standard reference materials (SRMs) are homogeneous, well-characterized materials used to validate measurements and improve the quality of analytical data. The National Institute of Standards and Technology (NIST) has a wide range of SRMs that have mass fraction values assigned for legacy pollutants

  18. DGNB certified Healthcare Centres

    DEFF Research Database (Denmark)

    Brunsgaard, Camilla; Larsen, Tine Steen

    2015-01-01

    In recent years, research and the building industry greatly focused on lowering and optimising the energy use of buildings during operation. It has resulted in several pilot projects which illustrate how it can be achieved. At the same time voluntary sustainability certification schemes (BEAM, LEED...... interviews of key actors in each design team. Each interview is analysed individually and summarised in a report. Finally the four cases are analysed in a comparative study which draw a picture of what kind of DMaDP the DGNB certified HCC have had. At time of writing the analysis of the interviews....... At the same time it made the design teams work more conscious with sustainable initiatives. Nevertheless, different perceptions of when and how the DGNB consultant and engineers should be part of the initial sketching phases exist. Some believe there need be at first architectural idea. Others believe...

  19. A study of production of radioactive environmental reference materials used for proficiency testing program in Taiwan.

    Science.gov (United States)

    Peng, En-Chi; Wang, Jeng-Jong

    2013-11-01

    To realise radioactive environmental reference materials in Taiwan, seven environmental materials of soil, water, vegetation, meat, airborne particles (filter paper), milk and mushroom samples that are frequently encountered were used to establish the preparation of the reference materials. These seven environmental materials were collected, checked for freedom from radioactivity and prepared according to their properties. The preparation was carried out by using activity about 10-100 times that of the minimum detectable activity (MDA) in routine measurements in the radioactive standard used to spike the inactive material and this standard is traceable to national ionising radioactivity standards (TAF, 2004). To demonstrate sample traceability to the added standard, each sample was carefully measured and its uncertainty evaluated. Based on the recommendations of ISO Guide 35 for evaluation of reference materials and with the above assessment and verification procedures, the uncertainties (k=1) of the spike activity used in making reference materials were: (60)Co≤4.6%, (134)Cs≤4.7%, (137)Cs≤5.0%, total β≤0.6% and (3)H≤1.3%.

  20. Microhomogeneity in reference materials for microanalytical methods - a possible recourse from a blind alley?

    Science.gov (United States)

    Renno, A. D.; Michalak, P. P.; Munnik, F.; Tolosana-Delgado, R.; van den Boogaart, G. K.

    2013-12-01

    It is assumed that reference materials for microanalytical methods must be homogeneous, i.e. have the same concentration of the relevant element(s) overall, to ensure that they can be used reliably to get comparison values during the analysis with non absolute methods. With increasing resolution it becomes more and more difficult to ensure such homogeneity, up to the point that it is not possible for several microanalytical methods. Painstaking search for homogeneous natural minerals in gem quality or elaborate expensive methods to produce synthetic minerals provide as obvious solutions to the problem. We propose a way to get reliable reference values with some types of inhomogeneous material, based on multiple probing the reference material. Consider a reference material, which average concentration on the relevant element and its microscale variability has been adequately characterized by a destructive method at a series of grid spots. The minimal number of probing spots required for a certain precision level can be derived from the variance calculations. This procedure is always valid, whenever the heterogeneity value distribution of the reference material has a variance, but at the price that the number of spots will be huge if it is large. However, using adequate models of local heterogeneity can greatly reduce that number. Geostatistics can be used in random, systematic and periodic heterogeneities, while robust methods are useful in cases of nugget heterogeneities. Typical examples of natural and synthetic minerals, analysed by electron microprobe and micro-PIXE (particle induced X-ray emission) for microhomogeneity/microheterogeneity are shown. The distinctions between the two strategies of using these materials as a potential reference material are demonstrated.

  1. 40 CFR 161.175 - Certified limits.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Certified limits. 161.175 Section 161... Certified limits. The applicant must propose certified limits for the ingredients in the product. Certified limits become legally binding limits upon approval of the application. Certified limits will apply to...

  2. Precise determination of silicon in ceramic reference materials by prompt gamma activation analysis at JRR-3

    Energy Technology Data Exchange (ETDEWEB)

    Miura, Tsutomu [National Metrology Institute of Japan-AIST, Ibaraki (Japan); Matsue, Hideaki [Quantum Beam Science Directorate, Japan Atomic Energy Agency, Ibaraki (Japan)

    2016-04-15

    Prompt gamma activation analysis using a thermal neutron-guided beam at Japan Atomic Energy Agency JRR-3M was applied for the precise determination of Si in silicon nitride ceramic reference materials [Japan Ceramic Reference Material (JCRM) R 003]. In this study, the standard addition method coupled with internal standard was used for the nondestructive determination of Si in the sample. Cadmium was used as internal standard to obtain the linear calibration curves and to compensate for the neutron beam variability. The analytical result of determining Si in JCRM R 003 silicon nitride fine powder ceramic reference materials using prompt gamma activation analysis was in good agreement with that obtained by classical gravimetric analysis. The relative expanded measurement uncertainty (k = 2) associated with the determined value was 2.4%.

  3. Reference materials and representative test materials to develop nanoparticle characterization methods: the NanoChOp project case

    Science.gov (United States)

    Roebben, Gert; Kestens, Vikram; Varga, Zoltan; Charoud-Got, Jean; Ramaye, Yannic; Gollwitzer, Christian; Bartczak, Dorota; Geißler, Daniel; Noble, James; Mazoua, Stéphane; Meeus, Nele; Corbisier, Philippe; Palmai, Marcell; Mihály, Judith; Krumrey, Michael; Davies, Julie; Resch-Genger, Ute; Kumarswami, Neelam; Minelli, Caterina; Sikora, Aneta; Goenaga-Infante, Heidi

    2015-10-01

    This paper describes the production and characteristics of the nanoparticle test materials prepared for common use in the collaborative research project NanoChOp (Chemical and optical characterisation of nanomaterials in biological systems), in casu suspensions of silica nanoparticles and CdSe/CdS/ZnS quantum dots. This paper is the first to illustrate how to assess whether nanoparticle test materials meet the requirements of a 'reference material' (ISO Guide 30:2015) or rather those of the recently defined category of 'representative test material' (ISO TS 16195:2013). The NanoChOp test materials were investigated with small-angle X-ray scattering (SAXS), dynamic light scattering (DLS) and centrifugal liquid sedimentation (CLS) to establish whether they complied with the required monomodal particle size distribution. The presence of impurities, aggregates, agglomerates and viable microorganisms in the suspensions was investigated with DLS, CLS, optical and electron microscopy and via plating on nutrient agar. Suitability of surface functionalization was investigated with attenuated total reflection Fourier transform infrared spectrometry (ATR-FTIR) and via the capacity of the nanoparticles to be fluorescently labeled or to bind antibodies. Between-unit homogeneity and stability were investigated in terms of particle size and zeta potential. This paper shows that only based on the outcome of a detailed characterization process one can raise the status of a test material to representative test material or reference material, and how this status depends on its intended use.

  4. Towards the development of standard reference materials for soot measurements – Part 1: Tailored graphitized soot

    Directory of Open Access Journals (Sweden)

    T. Khokhlova

    2010-04-01

    Full Text Available The lack of standard reference materials for calibrating, troubleshooting and intercomparing instruments that measure the properties of black carbon, commonly referred to as soot, has been a major obstacle that hinders improved understanding of how climate and health is impacted by this ubiquitous component of the atmosphere. A different approach is offered here as a means of constructing precisely controlled material with fractions of organic carbon (OC on the surface of elemental carbon (EC whose structure reflects that of combustion particles found in the atmosphere. The proposed soot reference material (SRM uses elemental carbon as a basis substrate for surface coatings of organic compounds that are representative of main classes of organics identified in the coverage of soot produced by fossil fuel burning. A number of methods are used to demonstrate the quality and stability of the reference EC and SRM. Comparison of the nominal fraction of OC deposited on the EC substrate with the fraction measured with thermal/optical analysis (TOA shows excellent agreement. Application of this type of reference material for evaluating the different methods of carbon analysis may help resolve differences that currently exist between comparable measurement techniques when trying to separate OC and EC from ambient samples.

  5. Tailored graphitized soot as reference material for EC/OC measurement validation

    Directory of Open Access Journals (Sweden)

    O. Popovicheva

    2011-05-01

    Full Text Available The lack of standard reference materials for calibrating, troubleshooting and intercomparing techniques that measure the composition of black carbon, commonly referred to as soot, has been a major obstacle that hinders improved understanding of how climate and health is impacted by this ubiquitous component of the atmosphere. A different approach is offered here as a means of constructing precisely controlled material with fractions of organic carbon (OC on the surface of elemental carbon (EC whose structure reflects that of the combustion produced particles found in the atmosphere. The proposed soot reference material (SRM uses EC as a basis substrate for surface coatings of organic compounds that are representative of the main classes of organics identified in the coverage of soot produced by fossil fuel burning. A number of methods are used to demonstrate the quality and stability of the reference EC and SRM. Comparison of the nominal fraction of OC deposited on the EC substrate with the fraction measured with thermal/optical analysis (TOA shows excellent agreement. Application of this type of reference material for evaluating the different methods of carbon analysis may help resolve differences that currently exist between comparable measurement techniques when trying to separate OC and EC from ambient samples.

  6. Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report)

    Science.gov (United States)

    Brand, Willi A.; Coplen, Tyler B.; Vogl, Jochen; Rosner, Martin; Prohaska, Thomas

    2014-01-01

    Since the early 1950s, the number of international measurement standards for anchoring stable isotope delta scales has mushroomed from 3 to more than 30, expanding to more than 25 chemical elements. With the development of new instrumentation, along with new and improved measurement procedures for studying naturally occurring isotopic abundance variations in natural and technical samples, the number of internationally distributed, secondary isotopic reference materials with a specified delta value has blossomed in the last six decades to more than 150 materials. More than half of these isotopic reference materials were produced for isotope-delta measurements of seven elements: H, Li, B, C, N, O, and S. The number of isotopic reference materials for other, heavier elements has grown considerably over the last decade. Nevertheless, even primary international measurement standards for isotope-delta measurements are still needed for some elements, including Mg, Fe, Te, Sb, Mo, and Ge. It is recommended that authors publish the delta values of internationally distributed, secondary isotopic reference materials that were used for anchoring their measurement results to the respective primary stable isotope scale.

  7. PAHs in baby food: assessment of three different processing techniques for the preparation of reference materials.

    Science.gov (United States)

    Huertas-Pérez, José Fernando; Bordajandi, Luisa R; Sejerøe-Olsen, Berit; Emteborg, Håkan; Baù, Andrea; Schimmel, Heinz; Dabrio, Marta

    2015-04-01

    A feasibility study for producing a matrix reference material for selected polycyclic aromatic hydrocarbons (PAHs) in baby food is reported. A commercially available baby food, containing carrots, potatoes, tomato, white beans and meat, was spiked with the so-called 15 + 1 PAHs included in the PAHs priority list for food of the EU, at a mass fraction level of 1 μg/kg. The contaminated baby food was further processed by autoclaving, freezing or freeze drying. The homogeneity of the three materials (bottle-to-bottle variation) and their short-term (4 weeks) and long-term (18 months) stability at different temperatures were assessed. To this end, an analytical method based on a solid-liquid extraction followed by cleaning up with gel permeation chromatography (GPC) and solid phase extraction (SPE) and GC-IDMS determination, was validated in-house. It could be demonstrated that the procedure fulfilled the demands for application to the homogeneity and isochronous stability studies for the candidate reference materials targeted here. All three materials proved to be sufficiently homogeneous for the intended use. Measurements on the autoclaved material provided the most promising results in terms of envisaged shelf life, although freeze drying was also found to be a suitable processing technique for most of the investigated PAHs. These results are an important step towards the development of a matrix reference material for PAHs in a processed food matrix in a presentation very similar to routine samples.

  8. Doorways III: Teacher Reference Materials. On School-Related Gender-Based Violence Prevention and Response

    Science.gov (United States)

    US Agency for International Development, 2009

    2009-01-01

    The Doorways training program was designed by the U.S. Agency for International Development (USAID)-funded Safe Schools Program (Safe Schools) to enable teachers, community members and students to prevent and respond to school-related gender-based violence (SRGBV). This booklet, "Doorways III: Teacher Reference Materials on School-Related…

  9. Sources of Braille Reading Materials. Reference Circular No. 86-2.

    Science.gov (United States)

    Redmond, Linda, Comp.

    This reference circular lists sources of braille books available for loan, purchase, rental, or free (give-away) distribution. Divided into four sections, it includes general sources of braille books, sources of specialized braille materials, the major braille presses, and resources for further information about braille books and magazines.…

  10. Future needs and requirements for AMS C-14 standards and reference materials

    NARCIS (Netherlands)

    Scott, EM; Boaretto, E; Bryant, C; Cook, GT; Gulliksen, S; Harkness, DD; Heinemeier, J; McGee, E; Naysmith, P; Possnert, G; van der Plicht, H; van Strydonck, M; Cook, Gordon T.

    2004-01-01

    C-14 measurement uses a number of standards and reference materials with different properties. Historically the absolute calibration of C-14 measurement was tied to 1890 wood, through the 'primary' standard of NBS-OxI (produced by the National Bureau of Standards, now NIST - National Institute of St

  11. [Perioperative mortality and morbidity for the year of 1999 in 466 Japanese Certified Anesthesia-training Hospitals: with special reference to ASA-physical status--report of Committee on Operating Room Safety of Japan Society of Anesthesiologists].

    Science.gov (United States)

    Irita, K; Kawashima, Y; Kobayashi, T; Goto, Y; Morita, K; Iwao, Y; Seo, N; Tsuzaki, K; Dohi, S

    2001-06-01

    Perioperative mortality and morbidity in Japan for the year 1999 were studied retrospectively. Committee on Operating Room Safety of the Japan Society of Anesthesiologists (JSA) sent confidential questionnaires to 774 Certified Training Hospitals of JSA and received answers from 60.2% of the hospitals. We analyzed their answers with special reference to ASA physical status (ASA-PS). The total number of anesthetics analyzed was 655, 644. Mortality and morbidity due to all kinds of causes including anesthetic management, intraoperative events, co-existing diseases, and operation were as follows. The incidence of cardiac arrest (per 10,000 anesthetics) was 0.68, 3.76, 14.37, 67.03, 0.36, 4.68, 27.96, 206.30 in patients with ASA-PS of I, II, III, IV, I E, II E, III E, and IV E, respectively. The incidences of critical events including cardiac arrest, severe hypotension, and severe hypoxemia were 8.93, 26.99, 71.30, 188.52, 8.68, 31.27, 136.16, and 790.92 in patients with ASA-PS of I, II, III, IV, I E, II E, III E, and IV E, respectively. The mortality rates (death during anesthesia and within 7th postoperative day) after cardiac arrest were 0.16, 0.94, 5.71, 33.51, 0.00, 1.46, 16.41 and 167.76 per 10,000 anesthetics in patients with ASA-PS of I, II, III, IV, I E, II E, III E, and IV E, respectively. The overall mortality rates were 0.24, 1.66, 12.16, 67.03, 0.00, 3.51, 34.65 and 417.14 in patients with ASA-PS of I, II, III, IV, I E, II E, III E, and IV E, respectively. Overall mortality and morbidity were higher in emergency anesthetics than in elective anesthetics. ASA-PS correlated well with overall mortality and with morbidity, regardless of etiology. The incidences of cardiac arrest totally attributable to anesthesia were 0.24, 0.45, 1.47, 8.38, 0.36, 1.75, 2.43 and 11.34 in patients with ASA-PS of I, II, III, IV, I E, II E, III E, and IV E, respectively. The incidences of all critical events totally attributable to anesthesia were 4.92, 8.81, 14.74, 20.95, 4

  12. [Perioperative mortality and morbidity in the year 2000 in 502 Japanese certified anesthesia-training hospitals: with a special reference to ASA-physical status--report of the Japan Society of Anesthesiologists Committee on Operating Room Safety].

    Science.gov (United States)

    Irita, Kazuo; Kawashima, Yasuo; Tsuzaki, Koichi; Iwao, Yasuhide; Kobayashi, Tsutomu; Seo, Norimasa; Goto, Yasuyuki; Morita, Kiyoshi; Shiraishi, Yoshito; Nakao, Yasuo; Tanaka, Yoshifumi; Tosaki, Youko; Dohi, Shuji; Obara, Hidefumi

    2002-01-01

    Perioperative mortality and morbidity in Japan from Jan. 1 to Dec. 31, 2000 were studied retrospectively. Committee on Operating Room Safety in Japanese Society of Anesthesiologists (JSA) sent confidential questionnaires to 794 certified training hospitals of JSA and received answers from 67.6% of the hospitals. We analyzed their answers with a special reference to ASA physical status (ASA-PS). The total number of anesthesia available for this analysis was 897,733. The percentages of patients with ASA-PS of I, II, III, IV, I E, II E, III E, and IV E are 38.0, 40.3, 8.5, 0.4, 4.3, 5.3, 2.5, and 0.7%, respectively. Mortality and morbidity from all kinds of causes including anesthetic management, intraoperative events, co-existing diseases, and surgical problems were as follows. The incidences of cardiac arrest (per 10,000 cases of anesthesia) were 1.11, 3.26, 12.25, 54.60, 0.77, 4.46, 21.08 and 217.75 in patients with ASA-PS of I, II, III, IV, I E, II E, III E, and IV E, respectively. The incidences of critical events including cardiac arrest, severe hypotension, and severe hypoxemia were 6.89, 20.22, 62.18, 148.21, 6.71, 20.38, 106.72 and 592.21 in patients with ASA-PS of I, II, III, IV, I E, II E, III E, and IV E, respectively. The mortality rates (death during anesthesia and within 7 postoperative days) after cardiac arrest were 0.26, 0.77, 3.69, 41.60, 0.00, 1.06, 9.42 and 163.31 per 10,000 cases of anesthesia in patients with ASA-PS of I, II, III, IV, I E, II E, III E, and IV E, respectively. The overall mortality rates were 0.32, 1.38, 9.75, 70.20, 0.26, 2.12, 29.15 and 353.02 in patients with ASA-PS of I, II, III, IV, I E, II E, III E, and IV E, respectively. Overall mortality and morbidity were higher in emergency anesthesia than in elective anesthesia. ASA-PS correlated well with overall mortality and morbidity, regardless of etiology. The incidences of cardiac arrest totally attributable to anesthesia were 0.23, 0.50, 1.32, 0.00, 0.00, 0.85, 2.69 and 4

  13. Characterizing a full spectrum of physico-chemical properties of ginsenosides rb1 and rg1 to be proposed as standard reference materials.

    Science.gov (United States)

    Kim, Il-Woung; Hong, Hee-Do; Choi, Sang Yoon; Hwang, Da-Hye; Her, Youl; Kim, Si-Kwan

    2011-11-01

    Good manufacturing practice (GMP)-based quality control is an integral component of the common technical document, a formal documentation process for applying a marketing authorization holder to those countries where ginseng is classified as a medicine. In addition, authentication of the physico-chemical properties of ginsenoside reference materials, and qualitative and quantitative batch analytical data based on validated analytical procedures are prerequisites for certifying GMP. Therefore, the aim of this study was to propose an authentication process for isolated ginsenosides Rb1 and Rg1 as reference materials (RM) and for these compounds to be designated as RMs for ginseng preparations throughout the world. Ginsenoside Rb1 and Rg1 were isolated by Diaion HP-20 adsorption chromatography, silica gel flash chromatography, recrystallization, and preparative HPLC. HPLC fractions corresponding to those two ginsenosides were recrystallized in appropriate solvents for the analysis of physico-chemical properties. Documentation of the isolated ginsenosides was made according to the method proposed by Gaedcke and Steinhoff. The ginsenosides were subjected to analyses of their general characteristics, identification, purity, content quantitation, and mass balance tests. The isolated ginsenosides were proven to be a single compound when analyzed by three different HPLC systems. Also, the water content was found to be 0.940% for Rb1 and 0.485% for Rg1, meaning that the net mass balance for ginsenoside Rb1 and Rg1 were 99.060% and 99.515%, respectively. From these results, we could assess and propose a full spectrum of physicochemical properties for the ginsenosides Rb1 and Rg1 as standard reference materials for GMP-based quality control.

  14. Using a Materials Database System as the Backbone for a Certified Quality System (AS/NZS ISO 9001:1994) for a Distance Education Centre.

    Science.gov (United States)

    Hughes, Norm

    The Distance Education Center (DEC) of the University of Southern Queensland (Australia) has developed a unique materials database system which is used to monitor pre-production, design and development, production and post-production planning, scheduling, and distribution of all types of materials including courses offered only on the Internet. In…

  15. Survey of inorganic arsenic in marine animals and marine certified reference materials by anion exchange high-performance liquid chromatography-inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Sloth, Jens Jørgen; Larsen, Erik Huusfeldt; Julshamn, Kåre

    2005-01-01

    A method for the determination of inorganic arsenic in seafood samples using high-performance liquid chromatography-inductively coupled plasma mass spectrometry is described. The principle of the method relied on microwave-assisted alkaline dissolution of the sample, which at the same time oxidized...... arsenite [As(Ill)] to arsenate [As(V)], whereby inorganic arsenic could be determined as the single species As(V). Anion exchange chromatography using isocratic elution with aqueous ammonium carbonate as the mobile phase was used for the separation of As(V) from other coextracted organoarsenic compounds......, including arsenobetaine. The stability of organoarsenic compounds during the sample pretreatment was investigated, and no degradation/conversion to inorganic arsenic was detected. The method was employed for the determination of inorganic arsenic in a variety of seafood samples including fish, crustaceans...

  16. ENERGY STAR Certified Imaging Equipment

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 2.0 ENERGY STAR Program Requirements for Imaging Equipment that are effective as of...

  17. ENERGY STAR Certified Water Coolers

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 2.0 ENERGY STAR Program Requirements for Water Coolers that are effective as of February...

  18. ENERGY STAR Certified Water Heaters

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 3.0 ENERGY STAR Program Requirements for Water Heaters that are effective April 16, 2015....

  19. ENERGY STAR Certified Commercial Dishwashers

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 2.0 ENERGY STAR Program Requirements for Commercial Dishwashers that are effective as of...

  20. ENERGY STAR Certified Vending Machines

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 3.0 ENERGY STAR Program Requirements for Refrigerated Beverage Vending Machines that are...

  1. ENERGY STAR Certified Residential Dishwashers

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 6.0 ENERGY STAR Program Requirements for Residential Dishwashers that are effective as of...

  2. ENERGY STAR Certified Commercial Fryers

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 3.0 ENERGY STAR Program Requirements for Commercial Fryers that are effective as of...

  3. Platinum stable isotope analysis of geological standard reference materials by double-spike MC-ICPMS

    DEFF Research Database (Denmark)

    Creech, John Benjamin; Baker, J. A.; Handler, M. R.

    2014-01-01

    We report a method for the chemical purification of Pt from geological materials by ion-exchange chromatography for subsequent Pt stable isotope analysis by multiple-collector inductively coupled plasma mass spectrometry (MC-ICPMS) using a Pt-Pt double-spike to correct for instrumental mass bias...... (Creech et al., 2013, J. Anal. At. Spectrom. 28, 853-865). The reproducibility in natural samples is evaluated by processing multiple replicates of four standard reference materials, and is conservatively taken to be ca. ±0.088 (2sd). Pt stable isotope data for the full set of reference materials have....... Double-spiking of samples was carried out prior to digestion and chemical separation to correct for any mass-dependent fractionation that may occur due to incomplete recovery of Pt. Samples were digested using a NiS fire assay method, which pre-concentrates Pt into a metallic bead that is readily...

  4. Present status and strategic plan for the stable isotope reference materials at the IAEA.

    Science.gov (United States)

    Assonov, Sergey; Groening, Manfred

    2016-04-01

    The presentation will give the overview of the stable isotope reference materials (SI-RMs) under distribution by the IAEA, its stable isotope laboratory and capacities related to material testing & production as well as future plans. Historically, most of the IAEA reference materials were produced and made available via collaborations with expert stable isotope laboratories worldwide. The IAEA plans include several directions as follows: • Maintaining the scale-defining SI-RMs at the highest level and introducing adequate replacements when needed; • Monitoring existing SI-RMs for any potential alteration(s) and of isotopic values assigned; • Identifying and then addressing the needs for new SI-RMs, with the priority to address the most critical applications (environmental and climate related applications, human health, food safety studies) and newly emerging analytical isotope techniques; • Performing all measurements aimed for characterisation of new SI-RMs and the corresponding uncertainty evaluation in accordance to the latest metrological concepts; • Promoting metrological approaches on traceability and uncertainty evaluation in every day practice of stable isotope measurements; • Expanding the IAEA capacities for SI-RMs by (i) planning a renewed laboratory at IAEA; (ii) enlarging collaboration with expert laboratories aimed to help IAEA in production and characterisation of new SI-RMs. These major directions will help to address the increasing demand for Stable Isotope Reference Materials.

  5. 2010年北京标准物质国际研讨会综述%Summary of RM 2010-Beijing International Symposium on Reference Materials

    Institute of Scientific and Technical Information of China (English)

    王亚平; 袁建; 许春雪

    2011-01-01

    This paper described the RM 2010-Beijing international symposium on reference materials, which is the largest conference in the history about reference materials international conference. The symposium was hosted by National Institute of Metrology P. R. China and supported by China Association for Instrumental Analysis and Chinese Society for Measurement. The themes of the symposium were mainly the current situation, future development trend, challenges of reference materials. The main themes included the relationships between the reference materials, environmental protection, international business and so on, the preparation, measurement methods and challenges for reference materials, current situations for national and international reference materials. The sessions of the symposium included about public security and health care, advanced materials for energy technology and environmental protection, developments and application of international reference materials, general analytical technology. The achievements in Chinese reference materials were presented through this conference and promoted the status of China about development of reference materials. The delegates communicated for the challenges and problems during the preparation for the reference materials. In this paper, we also summarized the main themes and the situation and application of Chinese reference materials, especially geological reference materials. Up to end of 2010, the totally 6011 kinds of referencematerials in China consists of 1701 first grade and 4310 second grade certified national reference materials, covering with steel, inorganic and industrial materials and so on. The numbers of reference materials reached international advanced level, however, there are some problems about lack of some species and categories along with unreasonable structure. The reference materials are short of in some important research fields as new resource, new energy, new materials, biology, clinical

  6. Statistical Analysis of a Round-Robin Measurement Survey of Two Candidate Materials for a Seebeck Coefficient Standard Reference Material.

    Science.gov (United States)

    Lu, Z Q J; Lowhorn, N D; Wong-Ng, W; Zhang, W; Thomas, E L; Otani, M; Green, M L; Tran, T N; Caylor, C; Dilley, N R; Downey, A; Edwards, B; Elsner, N; Ghamaty, S; Hogan, T; Jie, Q; Li, Q; Martin, J; Nolas, G; Obara, H; Sharp, J; Venkatasubramanian, R; Willigan, R; Yang, J; Tritt, T

    2009-01-01

    In an effort to develop a Standard Reference Material (SRM™) for Seebeck coefficient, we have conducted a round-robin measurement survey of two candidate materials-undoped Bi2Te3 and Constantan (55 % Cu and 45 % Ni alloy). Measurements were performed in two rounds by twelve laboratories involved in active thermoelectric research using a number of different commercial and custom-built measurement systems and techniques. In this paper we report the detailed statistical analyses on the interlaboratory measurement results and the statistical methodology for analysis of irregularly sampled measurement curves in the interlaboratory study setting. Based on these results, we have selected Bi2Te3 as the prototype standard material. Once available, this SRM will be useful for future interlaboratory data comparison and instrument calibrations.

  7. 40 CFR 158.350 - Certified limits.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Certified limits. 158.350 Section 158... REQUIREMENTS FOR PESTICIDES Product Chemistry § 158.350 Certified limits. The applicant must propose certified limits for the ingredients in the product. Certified limits become legally binding limits upon...

  8. Measurement of polybrominated diphenyl ethers in environmental matrix standard reference materials

    Energy Technology Data Exchange (ETDEWEB)

    Stapleton, H.; Schantz, M.; Wise, S. (National Institute of Standards and Technology)

    2004-09-15

    Polybrominated diphenyl ethers (PBDEs) are a class of emerging contaminants of concern as many studies have now demonstrated that these compounds are bioaccumulative, persistent and increasing in concentration in the environment. PBDEs are being detected in almost every environmental sample examined, and they have even been measured in samples collected in the Arctic, further demonstrating their persistence and potential for long range transport. More and more studies are continuing to examine the fate and transport of these flame retardant compounds in environmental samples and as such, reference materials are needed to provide quality control on these measurements. The National Institute of Standards and Technology (NIST) supports a national Standard Reference Material (SRM) program for measurement of organic contaminants such as PCBs, PAHs and chlorinated pesticides in environmental matrices. This current study was undertaken to provide reference measurements for PBDEs in selected SRMs that are currently used by various laboratories throughout the United States. These SRMs include matrices such as marine mammal blubber, lake trout tissue, mussel tissue, sediment, house dust and human serum. We report here reference values for 22 PBDE congeners that have been quantified in these seven types of SRMs.

  9. Software Management Environment (SME) release 9.4 user reference material

    Science.gov (United States)

    Hendrick, R.; Kistler, D.; Manter, K.

    1992-01-01

    This document contains user reference material for the Software Management Environment (SME) prototype, developed for the Systems Development Branch (Code 552) of the Flight Dynamics Division (FDD) of Goddard Space Flight Center (GSFC). The SME provides an integrated set of management tools that can be used by software development managers in their day-to-day management and planning activities. This document provides an overview of the SME, a description of all functions, and detailed instructions concerning the software's installation and use.

  10. The role of adequate reference materials in density measurements in hemodialysis

    Science.gov (United States)

    Furtado, A.; Moutinho, J.; Moura, S.; Oliveira, F.; Filipe, E.

    2015-02-01

    In hemodialysis, oscillation-type density meters are used to measure the density of the acid component of the dialysate solutions used in the treatment of kidney patients. An incorrect density determination of this solution used in hemodialysis treatments can cause several and adverse events to patients. Therefore, despite the Fresenius Medical Care (FME) tight control of the density meters calibration results, this study shows the benefits of mimic the matrix usually measured to produce suitable reference materials for the density meter calibrations.

  11. Consensus evaluation of radioactivity-in-soil reference materials in the context of an NPL Environmental Radioactivity Proficiency Test Exercise.

    Science.gov (United States)

    Dean, Julian; Collins, Sean; Garcia Miranda, Maria; Ivanov, Peter; Larijani, Cyrus; Woods, Selina

    2017-01-25

    The development of two radioactivity-in-soil reference materials is described - one for peat and one for soil with high sand content. Each bulk material was processed, subdivided and measured before being sent to participants in an NPL Environmental Radioactivity Proficiency Test Exercise. Activity concentrations of radionuclides in each material were determined by 'consensus' evaluations of participants' results using two weighted mean methods. The project demonstrated the use of such exercises in delivering reference materials to the user community.

  12. Developing a reference material for diffusion-controlled formaldehyde emissions testing.

    Science.gov (United States)

    Liu, Zhe; Liu, Xiaoyu; Zhao, Xiaomin; Cox, Steven S; Little, John C

    2013-11-19

    Formaldehyde, a known human carcinogen and mucous membrane irritant, is emitted from a variety of building materials and indoor furnishings. The drive to improve building energy efficiency by decreasing ventilation rates increases the need to better understand emissions from indoor products and to identify and develop lower emitting materials. To help meet this need, formaldehyde emissions from indoor materials are typically measured using environmental chambers. However, chamber testing results are frequently inconsistent and provide little insight into the mechanisms governing emissions. This research addresses these problems by (1) developing a reference formaldehyde emissions source that can be used to validate chamber testing methods for characterization of dynamic sources of formaldehyde emissions and (2) demonstrating that emissions from finite formaldehyde sources can be predicted using a fundamental mass-transfer model. Formaldehyde mass-transfer mechanisms are elucidated, providing practical approaches for developing diffusion-controlled reference materials that mimic actual sources. The fundamental understanding of emissions mechanisms can be used to improve emissions testing and guide future risk reduction actions.

  13. REIMEP-22 inter-laboratory comparison. ''U Age Dating - determination of the production date of a uranium certified test sample''

    Energy Technology Data Exchange (ETDEWEB)

    Venchiarutti, Celia; Richter, Stephan; Jakopic, Rozle; Aregbe, Yetunde [European Commission, Joint Research Centre (JRC), Geel (Belgium). Institute for Reference Materials and Measurements (IRMM); Varga, Zsolt; Mayer, Klaus [European Commission, Joint Research Centre (JRC), Karlsruhe (Germany). Institute for Transuranium Elements (ITU)

    2015-07-01

    The REIMEP-22 inter-laboratory comparison aimed at determining the production date of a uranium certified test sample (i.e. the last chemical separation date of the material). Participants in REIMEP-22 on ''U Age Dating - Determination of the production date of a uranium certified test sample'' received one low-enriched 20 mg uranium sample for mass spectrometry measurements and/or one 50 mg uranium sample for a-spectrometry measurements, with an undisclosed value for the production date. They were asked to report the isotope amount ratios n({sup 230}Th)/n({sup 234}U) for the 20 mg uranium sample and/or the activity ratios A({sup 230}Th)/A({sup 234}U) for the 50 mg uranium sample in addition to the calculated production date of the certified test samples with its uncertainty. Reporting of the {sup 231}Pa/{sup 235}U ratio and the respective calculated production date was optional. Eleven laboratories reported results in REIMEP-22. Two of them reported results for both the 20 mg and 50 mg uranium certified test samples. The measurement capability of the participants was assessed against the independent REIMEP-22 reference value by means of z- and zeta-scores in compliance with ISO 13528:2005. Furthermore a performance assessment criterion for acceptable uncertainty was applied to evaluate the participants' results. In general, the REIMEP-22 participants' results were satisfactory. This confirms the analytical capabilities of laboratories to determine accurately the age of uranium materials with low amount of ingrown thorium (young certified test sample). The Joint Research Centre of the European Commission (EC-JRC) organised REIMEP-22 in parallel to the preparation and certification of a uranium reference material certified for the production date (IRMM-1000a and IRMM-1000b).

  14. TOGAF 9 certified study guide

    CERN Document Server

    Group, The Open

    2010-01-01

    The TOGAF 9 certification program is a knowledge-based certification program. It has two levels, leading to certification for TOGAF 9 Foundation and TOGAF 9 Certified, respectively. The purpose of certification to TOGAF 9 Certified is to provide validation that, in addition to the knowledge and comprehension of TOGAF 9 Foundation level, the Candidate is able to analyze and apply this knowledge. The learning objectives at this level therefore focus on application and analysis in addition to knowledge and comprehension.This Study Guide supports students in preparation for the TOGAF 9 Part 2 Exam

  15. Seeking Coalitions between Certified and Non-Certified Art Educators

    Science.gov (United States)

    Lackey, Lara M.; Chou, Chun-Ming; Hsu, Pei-Lan

    2010-01-01

    This article explores the following question, posed in the call for submissions to this special issue, dealing with significant 21st-century debates for art education: "How can art educators embrace non-certified individuals who teach art in various settings such as craft stores, after-school programs, and community centers?" While the question…

  16. Statistical Analysis of a Round-Robin Measurement Survey of Two Candidate Materials for a Seebeck Coefficient Standard Reference Material

    Directory of Open Access Journals (Sweden)

    Lu, Z. Q. J.

    2009-01-01

    Full Text Available In an effort to develop a Standard Reference Material (SRM™ for Seebeck coefficient, we have conducted a round-robin measurement survey of two candidate materials—undoped Bi2Te3 and Constantan (55 % Cu and 45 % Ni alloy. Measurements were performed in two rounds by twelve laboratories involved in active thermoelectric research using a number of different commercial and custom-built measurement systems and techniques. In this paper we report the detailed statistical analyses on the interlaboratory measurement results and the statistical methodology for analysis of irregularly sampled measurement curves in the interlaboratory study setting. Based on these results, we have selected Bi2Te3 as the prototype standard material. Once available, this SRM will be useful for future interlaboratory data comparison and instrument calibrations.

  17. CEH Certified Ethical Hacker Study Guide

    CERN Document Server

    Graves, Kimberly

    2010-01-01

    Prepare for the new version of CEH certification with this advanced guide. Once you learn the thought processes of unethical hackers, you can figure out how to secure your computer systems to defend against them. That's the philosophy behind ethical hacking, and it's a growing field. Prepare for certification in this important area with this advanced study guide that covers all exam objectives for the challenging CEH Certified Ethical Hackers exam. The book provides full coverage of exam topics, real-world examples, and a CD with additional materials for extra review and practice.:; Covers eth

  18. 76 FR 80741 - TRICARE: Certified Mental Health Counselors

    Science.gov (United States)

    2011-12-27

    .... 13132. List of Subjects in 32 CFR Part 199 Claims, Dental health, Health care, Health insurance... referred for therapy by a physician; and (ii) A physician is providing ongoing oversight and supervision of the therapy being provided; and (iii) The mental health counselor certifies on each claim...

  19. Bias in the absorption coefficient determination of a fluorescent dye, standard reference material 1932 fluorescein solution

    Energy Technology Data Exchange (ETDEWEB)

    DeRose, Paul C. [Analytical Chemistry Division, National Institute of Standards and Technology, 100 Bureau Dr., Gaithersburg, MD 20899-8394 (United States)]. E-mail: paul.derose@nist.gov; Kramer, Gary W. [Analytical Chemistry Division, National Institute of Standards and Technology, 100 Bureau Dr., Gaithersburg, MD 20899-8394 (United States)

    2005-06-15

    The absorption coefficient of standard reference material[registered] (SRM[registered]) 1932, fluorescein in a borate buffer solution (pH=9.5) has been determined at {lambda}=488.0, 490.0, 490.5 and 491.0 nm using the US national reference UV/visible spectrophotometer. The purity of the fluorescein was determined to be 97.6% as part of the certification of SRM 1932. The solution measured was prepared gravimetrically by diluting SRM 1932 with additional borate buffer. The value of the absorption coefficient was corrected for bias due to fluorescence that reaches the detector and for dye purity. Bias due to fluorescence was found to be on the order of -1% for both monochromatic and polychromatic (e.g., diode-array based) spectrophotometers.

  20. Short-term stability test for thorium soil candidate a reference material

    Energy Technology Data Exchange (ETDEWEB)

    Clain, Almir F.; Fonseca, Adelaide M.G.; Dantas, Vanessa V.D.B.; Braganca, Maura J.C.; Souza, Poliana S., E-mail: almir@ird.gov.br, E-mail: adelaide@ird.gov.br, E-mail: vanessa@ird.gov.br, E-mail: maura@ird.gov.br, E-mail: poliana@bolsista.ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    This work describes a methodology to determine the soil short-term stability after the steps of production in laboratory. The short-term stability of the soil is an essential property to be determined in order to producing a reference material. The soil is a candidate of reference material for chemical analysis of thorium with metrological traceability to be used in environmental analysis, equipment calibration, validation methods, and quality control. A material is considered stable in a certain temperature if the property of interest does not change with time, considering the analytical random fluctuations. Due to this, the angular coefficient from the graphic of Th concentration versus elapsed time must be near to zero. The analytical determinations of thorium concentration were performed by Instrumental Neutron activation Analysis. The slopes and their uncertainties were obtained from the regression lines at temperatures of 20 deg C and 60 deg C, with control temperature of -20 deg C. From the obtained data a t-test was applied. In both temperatures the calculated t-value was lower than the critical value, so we can conclude with 95% confidence level that no significant changes happened during the period studied concerning thorium concentration in soil at temperatures of 20 deg C and 60 deg C, showing stability at these temperatures. (author)

  1. Results of a Saxitoxin Proficiency Test Including Characterization of Reference Material and Stability Studies

    Directory of Open Access Journals (Sweden)

    Kirsi Harju

    2015-11-01

    Full Text Available A saxitoxin (STX proficiency test (PT was organized as part of the Establishment of Quality Assurance for the Detection of Biological Toxins of Potential Bioterrorism Risk (EQuATox project. The aim of this PT was to provide an evaluation of existing methods and the European laboratories’ capabilities for the analysis of STX and some of its analogues in real samples. Homogenized mussel material and algal cell materials containing paralytic shellfish poisoning (PSP toxins were produced as reference sample matrices. The reference material was characterized using various analytical methods. Acidified algal extract samples at two concentration levels were prepared from a bulk culture of PSP toxins producing dinoflagellate Alexandrium ostenfeldii. The homogeneity and stability of the prepared PT samples were studied and found to be fit-for-purpose. Thereafter, eight STX PT samples were sent to ten participating laboratories from eight countries. The PT offered the participating laboratories the possibility to assess their performance regarding the qualitative and quantitative detection of PSP toxins. Various techniques such as official Association of Official Analytical Chemists (AOAC methods, immunoassays, and liquid chromatography-mass spectrometry were used for sample analyses.

  2. Certifiable Java for Embedded Systems

    DEFF Research Database (Denmark)

    Schoeberl, Martin; Dalsgaard, Andreas Engelbredt; Hansen, Rene Rydhof

    2014-01-01

    The Certifiable Java for Embedded Systems (CJ4ES) project aimed to develop a prototype development environment and platform for safety-critical software for embedded applications. There are three core constituents: A profile of the Java programming language that is tailored for safety...

  3. Development of a standard reference material for Cr(vi) in contaminated soil

    Science.gov (United States)

    Nagourney, S.J.; Wilson, S.A.; Buckley, B.; Kingston, H.M.S.; Yang, S.-Y.; Long, S.E.

    2008-01-01

    Over the last several decades, considerable contamination by hexavalent chromium has resulted from the land disposal of Chromite Ore Processing Residue (COPR). COPR contains a number of hexavalent chromium-bearing compounds that were produced in high temperature industrial processes. Concern over the carcinogenic potential of this chromium species, and its environmental mobility, has resulted in efforts to remediate these waste sites. To provide support to analytical measurements of hexavalent chromium, a candidate National Institute of Standards and Technology (NIST) Standard Reference Material?? (SRM 2701), having a hexavalent chromium content of approximately 500 mg kg -1, has been developed using material collected from a waste site in Hudson County, New Jersey, USA. The collection, processing, preparation and preliminary physico-chemical characterization of the material are discussed. A two-phase multi-laboratory testing study was carried out to provide data on material homogeneity and to assess the stability of the material over the duration of the study. The study was designed to incorporate several United States Environmental Protection Agency (USEPA) determinative methods for hexavalent chromium, including Method 6800 which is based on speciated isotope dilution mass spectrometry (SIDMS), an approach which can account for chromium species inter-conversion during the extraction and measurement sequence. This journal is ?? The Royal Society of Chemistry 2008.

  4. Organomercury determination in biological reference materials: application to a study on mercury speciation in marine mammals off the Faröe Islands.

    Science.gov (United States)

    Schintu, M; Jean-Caurant, F; Amiard, J C

    1992-08-01

    The potential use of graphite furnace atomic absorption spectrometry (GF-AAS) for the organic mercury determination in marine biological tissues was evaluated. Following its isolation by acid extraction in toluene, organic mercury was recovered in aqueous thiosulfate and measured by GF-AAS. The detection limit was 0.01 microgram Hg/g (as methyl mercury). Analyses were conducted on three reference standard materials certified for their methyl mercury content, DOLT-1, DORM-1, and TORT-1, provided by the National Research Council of Canada. The method resulted in very good recovery and reproducibility, indicating that GF-AAS can provide results comparable to those obtained by using more expensive and time consuming analytical techniques. The method was applied to the analysis of liver tissues of pilot whale specimens (Globicephala melas) from the drive fishery of the Faröe Islands (northeast Atlantic). The results provided useful information on the proportion of different mercury forms in the liver of these marine mammals.

  5. Toward New High Temperature Reference Materials for Calorimetry and Thermal Analysis

    Directory of Open Access Journals (Sweden)

    Razouk R.

    2014-01-01

    Full Text Available The French National Metrology Laboratory LNE-LCM has developed a high temperature reference facility for accurate measurements of the specific heat capacity and of the enthalpy of fusion of materials over the temperature range [23 °C, 1000 °C]. The metrological approach was to modify a commercial Calvet calorimeter in order to lower the uncertainty of measurement and to insure the metrological traceability of the measurements to the SI units, in particular by designing a new calibration system. The enthalpies of fusion of pure metals (indium, tin and silver and of a binary alloy Ag-28Cu have been measured. The results obtained on the three pure metallic materials are in very good agreement with data obtained by other National Metrology Institutes (NMIs using adiabatic calorimetry.

  6. Protein standardization V: value transfer. A practical protocol for the assignment of serum protein values from a Reference Material to a Target Material.

    Science.gov (United States)

    Blirup-Jensen, Søren; Johnson, A Myron; Larsen, Marianne

    2008-01-01

    We present a practical protocol for the assignment of values to serum proteins in a Target Material using a Reference Material. This protocol is based on the model of Direct Value Transfer between serum matrices and is intended to improve the value assignment of commercial calibrators using the Reference Material CRM 470 (now labeled ERM-DA 470) or similar reference materials. The procedure describes the general as well as the practical principles involved in the value assignment (with examples). The practical transfer protocol is based on multiple assays of 6 dilutions of the Reference Material and 6 dilutions of the Target Material. The transfer protocol requires several measurements a day repeated on several days, an important prerequisite being that all reconstitutions and dilutions are controlled by weighing thus reducing uncertainty in the transfer. In open systems that allow the use of the Reference Material as calibrator and the Target Material as samples, the proportionality of the two materials (the presence or absence of matrix effects) can now be directly assessed by evaluating a single regression plot. If no matrix effects are found, the regression line will pass through zero with a slope equal to the ratio of the concentrations of the two materials. In closed systems, the dedicated commercial calibrator has to be used as such; the Reference Material and the Target Material are now assayed as samples against this calibrator. Two regression plots are therefore obtained; if no matrix effects are present among the two materials and the calibrator, both the Reference and Target Materials will show zero intercepts, and the ratio of the two slopes will equal the ratio of the concentrations.

  7. Development and application of a general plasmid reference material for GMO screening.

    Science.gov (United States)

    Wu, Yuhua; Li, Jun; Wang, Yulei; Li, Xiaofei; Li, Yunjing; Zhu, Li; Li, Jun; Wu, Gang

    The use of analytical controls is essential when performing GMO detection through screening tests. Additionally, the presence of taxon-specific sequences is analyzed mostly for quality control during GMO detection. In this study, 11 commonly used genetic elements involving three promoters (P-35S, P-FMV35S and P-NOS), four marker genes (Bar, NPTII, HPT and Pmi), and four terminators (T-NOS, T-35S, T-g7 and T-e9), together with the reference gene fragments from six major crops of maize, soybean, rapeseed, rice, cotton and wheat, were co-integrated into the same single plasmid to construct a general reference plasmid pBI121-Screening. The suitability test of pBI121-Screening plasmid as reference material indicated that the non-target sequence on the pBI121-Screening plasmid did not affect the PCR amplification efficiencies of screening methods and taxon-specific methods. The sensitivity of screening and taxon-specific assays ranged from 5 to 10 copies of pBI121-Screening plasmid, meeting the sensitivity requirement of GMO detection. The construction of pBI121-Screening solves the lack of a general positive control for screening tests, thereby reducing the workload and cost of preparing a plurality of the positive control.

  8. Periodic reference tracking control approach for smart material actuators with complex hysteretic characteristics

    Science.gov (United States)

    Sun, Zhiyong; Hao, Lina; Song, Bo; Yang, Ruiguo; Cao, Ruimin; Cheng, Yu

    2016-10-01

    Micro/nano positioning technologies have been attractive for decades for their various applications in both industrial and scientific fields. The actuators employed in these technologies are typically smart material actuators, which possess inherent hysteresis that may cause systems behave unexpectedly. Periodic reference tracking capability is fundamental for apparatuses such as scanning probe microscope, which employs smart material actuators to generate periodic scanning motion. However, traditional controller such as PID method cannot guarantee accurate fast periodic scanning motion. To tackle this problem and to conduct practical implementation in digital devices, this paper proposes a novel control method named discrete extended unparallel Prandtl-Ishlinskii model based internal model (d-EUPI-IM) control approach. To tackle modeling uncertainties, the robust d-EUPI-IM control approach is investigated, and the associated sufficient stabilizing conditions are derived. The advantages of the proposed controller are: it is designed and represented in discrete form, thus practical for digital devices implementation; the extended unparallel Prandtl-Ishlinskii model can precisely represent forward/inverse complex hysteretic characteristics, thus can reduce modeling uncertainties and benefits controllers design; in addition, the internal model principle based control module can be utilized as a natural oscillator for tackling periodic references tracking problem. The proposed controller was verified through comparative experiments on a piezoelectric actuator platform, and convincing results have been achieved.

  9. Extensive sequencing of seven human genomes to characterize benchmark reference materials.

    Science.gov (United States)

    Zook, Justin M; Catoe, David; McDaniel, Jennifer; Vang, Lindsay; Spies, Noah; Sidow, Arend; Weng, Ziming; Liu, Yuling; Mason, Christopher E; Alexander, Noah; Henaff, Elizabeth; McIntyre, Alexa B R; Chandramohan, Dhruva; Chen, Feng; Jaeger, Erich; Moshrefi, Ali; Pham, Khoa; Stedman, William; Liang, Tiffany; Saghbini, Michael; Dzakula, Zeljko; Hastie, Alex; Cao, Han; Deikus, Gintaras; Schadt, Eric; Sebra, Robert; Bashir, Ali; Truty, Rebecca M; Chang, Christopher C; Gulbahce, Natali; Zhao, Keyan; Ghosh, Srinka; Hyland, Fiona; Fu, Yutao; Chaisson, Mark; Xiao, Chunlin; Trow, Jonathan; Sherry, Stephen T; Zaranek, Alexander W; Ball, Madeleine; Bobe, Jason; Estep, Preston; Church, George M; Marks, Patrick; Kyriazopoulou-Panagiotopoulou, Sofia; Zheng, Grace X Y; Schnall-Levin, Michael; Ordonez, Heather S; Mudivarti, Patrice A; Giorda, Kristina; Sheng, Ying; Rypdal, Karoline Bjarnesdatter; Salit, Marc

    2016-06-07

    The Genome in a Bottle Consortium, hosted by the National Institute of Standards and Technology (NIST) is creating reference materials and data for human genome sequencing, as well as methods for genome comparison and benchmarking. Here, we describe a large, diverse set of sequencing data for seven human genomes; five are current or candidate NIST Reference Materials. The pilot genome, NA12878, has been released as NIST RM 8398. We also describe data from two Personal Genome Project trios, one of Ashkenazim Jewish ancestry and one of Chinese ancestry. The data come from 12 technologies: BioNano Genomics, Complete Genomics paired-end and LFR, Ion Proton exome, Oxford Nanopore, Pacific Biosciences, SOLiD, 10X Genomics GemCode WGS, and Illumina exome and WGS paired-end, mate-pair, and synthetic long reads. Cell lines, DNA, and data from these individuals are publicly available. Therefore, we expect these data to be useful for revealing novel information about the human genome and improving sequencing technologies, SNP, indel, and structural variant calling, and de novo assembly.

  10. Soot Reference Materials for instrument calibration and intercomparisons: a workshop summary with recommendations

    Directory of Open Access Journals (Sweden)

    D. Baumgardner

    2012-03-01

    Full Text Available Soot, which is produced from biomass burning and the incomplete combustion of fossil and biomass fuels, has been linked to regional and global climate change and to negative health problems. Scientists measure soot using a variety of methods in order to quantify source emissions and understand its atmospheric chemistry, reactivity under emission conditions, interaction with solar radiation, influence on clouds, and health impacts. A major obstacle currently limiting progress is the absence of established standards or reference materials for calibrating the many instruments used to measure the various properties of soot.

    The current state of availability and practicability of soot standard reference materials (SRMs was reviewed by a group of 50 international experts during a workshop in June of 2011. The workshop was convened to summarize the current knowledge on soot measurement techniques, identify the measurement uncertainties and limitations related to the lack of SRMs, and identify attributes of SRMs that, if developed, would reduce measurement uncertainties. The workshop established that suitable SRMs are available for calibrating some, but not all, measurement methods. The community of single-particle sootphotometer (SP2 users identified a suitable SRM, fullerene soot, but users of instruments that measure light absorption by soot collected on filters did not. Similarly, those who use thermal optical analysis (TOA to analyze the organic and elemental carbon components of soot were not satisfied with current SRMs. The workshop produced recommendations for the development of new SRMs that would be suitable for the different soot measurement methods.

  11. Palm-based standard reference materials for iodine value and slip melting point.

    Science.gov (United States)

    Tarmizi, Azmil Haizam Ahmad; Lin, Siew Wai; Kuntom, Ainie

    2008-09-22

    This work described study protocols on the production of Palm-Based Standard Reference Materials for iodine value and slip melting point. Thirty-three laboratories collaborated in the inter-laboratory proficiency tests for characterization of iodine value, while thirty-two laboratories for characterization of slip melting point. The iodine value and slip melting point of palm oil, palm olein and palm stearin were determined in accordance to MPOB Test Methods p3.2:2004 and p4.2:2004, respectively. The consensus values and their uncertainties were based on the acceptability of statistical agreement of results obtained from collaborating laboratories. The consensus values and uncertainties for iodine values were 52.63 +/- 0.14 Wijs in palm oil, 56.77 +/- 0.12 Wijs in palm olein and 33.76 +/- 0.18 Wijs in palm stearin. For the slip melting points, the consensus values and uncertainties were 35.6 +/- 0.3 degrees C in palm oil, 22.7 +/- 0.4 degrees C in palm olein and 53.4 +/- 0.2 degrees C in palm stearin. Repeatability and reproducibility relative standard deviations were found to be good and acceptable, with values much lower than that of 10%. Stability of Palm-Based Standard Reference Materials remained stable at temperatures of -20 degrees C, 0 degrees C, 6 degrees C and 24 degrees C upon storage for one year.

  12. Accuracy of ELISA detection methods for gluten and reference materials: a realistic assessment.

    Science.gov (United States)

    Diaz-Amigo, Carmen; Popping, Bert

    2013-06-19

    The determination of prolamins by ELISA and subsequent conversion of the resulting concentration to gluten content in food appears to be a comparatively simple and straightforward process with which many laboratories have years-long experience. At the end of the process, a value of gluten, expressed in mg/kg or ppm, is obtained. This value often is the basis for the decision if a product can be labeled gluten-free or not. On the basis of currently available scientific information, the accuracy of the obtained values with commonly used commercial ELISA kits has to be questioned. Although recently several multilaboratory studies have been conducted in an attempt to emphasize and ensure the accuracy of the results, data suggest that it was the precision of these assays, not the accuracy, that was confirmed because some of the underlying assumptions for calculating the gluten content lack scientific data support as well as appropriate reference materials for comparison. This paper discusses the issues of gluten determination and quantification with respect to antibody specificity, extraction procedures, reference materials, and their commutability.

  13. Determination of plutonium isotopes in seawater reference materials using isotope-dilution ICP-MS.

    Science.gov (United States)

    Zheng, Jian; Yamada, Masatoshi

    2012-09-01

    We analyzed the activities of (239)Pu, (240)Pu, (239+240)Pu, (241)Pu, the ratio of number of atoms (atom ratio) for (240)Pu/(239)Pu, and the activity ratio of (241)Pu/(239+240)Pu in seawater reference materials, IAEA-443 and IAEA-381, using a highly sensitive isotope dilution sector field inductively coupled plasma mass spectrometry method. With a mean chemical yield of 65% determined with (242)Pu as a tracer, we found that the experimentally established values in IAEA-443 for (239)Pu, (240)Pu, (241)Pu and (239+240)Pu activities are almost the same as those in IAEA-381. Regarding the (239+240)Pu activity, we provided the most precise and accurate result among the twelve laboratories, which participated in the interlaboratory comparison. In addition, for the (240)Pu/(239)Pu atom ratio, our results for IAEA-381 (0.2315±0.0008) and IAEA-443 (0.2325±0.0008) are in good agreement with the IAEA information value (0.229±0.006), but have much smaller uncertainty. Since the new seawater reference material, IAEA-443, is commercially available, it can be used not only for method validation for seawater plutonium isotope ratio and activity analysis, but also for more general use as a plutonium isotope standard for mass discrimination correction for other environmental samples.

  14. 7 CFR 983.7 - Certified pistachios.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Certified pistachios. 983.7 Section 983.7 Agriculture... and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE PISTACHIOS GROWN IN CALIFORNIA, ARIZONA, AND NEW MEXICO Definitions § 983.7 Certified pistachios. Certified pistachios are those that...

  15. 7 CFR 1221.4 - Certified organization.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Certified organization. 1221.4 Section 1221.4 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... organization. Certified organization means any organization that has been certified by the Secretary...

  16. 7 CFR 1280.103 - Certified organization.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Certified organization. 1280.103 Section 1280.103 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... organization. Certified organization means any organization which has been certified by the Secretary...

  17. 肠侵袭性大肠埃希氏菌国家核酸标准样品的研制%Development of Enteroinvasive Escherichia coli nucleic acid reference material

    Institute of Scientific and Technical Information of China (English)

    那晗; 倪长鹏; 刘宇; 吴远高; 徐君怡; 郑秋月

    2015-01-01

    目的:研制肠侵袭性大肠埃希氏菌核酸标准样品,并对其均匀性和稳定性进行评价。方法本文研究了肠侵袭性大肠埃希氏菌核酸标准样品的关键制备技术和保存技术,定值技术和定值方式,开展均匀性和稳定性试验,并对食品中肠侵袭性大肠埃希氏菌核酸标准样品的不确定度进行确定;标准样品采用 PicoGreen DNA 分子荧光定量方法进行定值。多家单位合作定值,确定标准样品的标准值及其不确定度。结果标准样品均匀性标准不确定度为0.016%,不稳定标准差为0.0100,均匀性和稳定性试验结果表明,本文研制的标准样品均匀且稳定。结论研制出具有溯源性的肠侵袭性大肠埃希氏菌核酸标准样品并获得国家标准样品证书,可适用于肠侵袭性大肠埃希氏菌的检测和质量控制。%Objective Enteroinvasive Escherichia Coli(EIEC) Molecular DNA Reference Material was developed, and uniformity and stability of test were evaluated. Methods The key preparation technology, saving technology, certified technique and mode for EIEC Molecular DNA Reference Material were researched, via uniformity and stability test. The uncertainty for EIEC Molecular DNA Reference Material was evaluated in food. The standard value was determined by PicoGreen DNA molecule fluorescence quantitative methods. Standard and uncertainty of reference material was determined by many units cooperation. Results Uniformity standard uncertainty of reference material was 0.016 %, unstable standard deviation was 0.0100. The result of uniformity and stability test showed that reference material developed in this study was uniform and stable. Conclusion EIEC Molecular DNA Reference Material with the traceability was developed, and certificate of national reference material was obtained. It could be used for quantitative detection and qualitative quality control of EIEC.

  18. Development of reference material for proficiency tests: arsenic in fish tissue

    Energy Technology Data Exchange (ETDEWEB)

    Santana, Luciana Vieira de; Sarkis, Jorge E.S.; Ulrich, Joao C.; Hortellani, Marcos Antonio, E-mail: santana-luciana@ig.com.br, E-mail: jesarkis@ipen.br, E-mail: jculrich@ipen.br, E-mail: mahortel@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Proficiency tests (PT) are extensively used to evaluate the analytical competence of laboratories, and are also used as a part of accreditation processes. For this reason are important tool for quality control of laboratories including laboratories that act directly with food exporting companies. In Brazil there are no providers of proficiency testing for toxic metals, such as arsenic in fish tissue. This study presents a protocol to produce reference material to be used in proficiency test for arsenic in fish tissue following the recommendations of the ISO Guide 35. The preparation scheme consisted of: selecting of individuals, cleaning of scale and skin, trituration, homogenization, and spiking with arsenic at two levels of concentration. The mixture was then irradiated in a cyclotron Cyclone 30 Applications ion beam with cobalt 60 at 10.00 ± 1.05 KGy, before being packed into sachets. To verify the efficacy of the irradiation procedure, 26 (randomly selected) irradiated sachets and 26 non-irradiated sachets were assessed for homogeneity and stability. The results indicate that irradiation with cobalt 60 is crucial for ensuring the preservation of the integrity of the material, providing stable material at room temperature for 2 months. The samples can therefore be transported at room temperature. (author)

  19. Palm-Based Standard Reference Materials for Iodine Value and Slip Melting Point

    Directory of Open Access Journals (Sweden)

    Azmil Haizam Ahmad Tarmizi

    2008-01-01

    Full Text Available This work described study protocols on the production of Palm-Based Standard Reference Materials for iodine value and slip melting point. Thirty-three laboratories collaborated in the inter-laboratory proficiency tests for characterization of iodine value, while thirty-two laboratories for characterization of slip melting point. The iodine value and slip melting point of palm oil, palm olein and palm stearin were determined in accordance to MPOB Test Methods p3.2:2004 and p4.2:2004, respectively. The consensus values and their uncertainties were based on the acceptability of statistical agreement of results obtained from collaborating laboratories. The consensus values and uncertainties for iodine values were 52.63 ± 0.14 Wijs in palm oil, 56.77 ± 0.12 Wijs in palm olein and 33.76 ± 0.18 Wijs in palm stearin. For the slip melting points, the consensus values and uncertainties were 35.6 ± 0.3 °C in palm oil, 22.7 ± 0.4 °C in palm olein and 53.4 ± 0.2 °C in palm stearin. Repeatability and reproducibility relative standard deviations were found to be good and acceptable, with values much lower than that of 10%. Stability of Palm-Based Standard Reference Materials remained stable at temperatures of –20 °C, 0 °C, 6 °C and 24 °C upon storage for one year.

  20. Soot reference materials for instrument calibration and intercomparisons: a workshop summary with recommendations

    Directory of Open Access Journals (Sweden)

    D. Baumgardner

    2012-08-01

    Full Text Available Soot, which is produced from biomass burning and the incomplete combustion of fossil and biomass fuels, has been linked to regional and global climate change and to negative health problems. Scientists measure the properties of soot using a variety of methods in order to quantify source emissions and understand its atmospheric chemistry, reactivity under emission conditions, interaction with solar radiation, influence on clouds, and health impacts. A major obstacle currently limiting progress is the absence of established standards or reference materials for calibrating the many instruments used to measure the various properties of soot.

    The current state of availability and practicability of soot standard reference materials (SRMs was reviewed by a group of 50 international experts during a workshop in June of 2011. The workshop was convened to summarize the current knowledge on soot measurement techniques, identify the measurement uncertainties and limitations related to the lack of soot SRMs, and identify attributes of SRMs that, if developed, would reduce measurement uncertainties. The workshop established that suitable SRMs are available for calibrating some, but not all, measurement methods. The community of users of the single-particle soot-photometer (SP2, an instrument using laser-induced incandescence, identified a suitable SRM, fullerene soot, but users of instruments that measure light absorption by soot collected on filters did not. Similarly, those who use thermal optical analysis (TOA to analyze the organic and elemental carbon components of soot were not satisfied with current SRMs. The workshop, and subsequent, interactive discussions, produced a number of recommendations for the development of new SRMs, and their implementation, that would be suitable for the different soot measurement methods.

  1. Compatibility of OMRI certified surfactants with three entomopathogenic fungi

    Science.gov (United States)

    The Organic Materials Review Institute (OMRI) is a nonprofit organization providing an independent review of products intended for use in organic production systems to certify compliance with U.S. National organic standards. Since all adjuvants to be used in organic agriculture production are requir...

  2. Certifiable Java for Embedded Systems

    DEFF Research Database (Denmark)

    Schoeberl, Martin; Hansen, René Rydhof; Ravn, Anders P.;

    2014-01-01

    The Certifiable Java for Embedded Systems (CJ4ES) project aimed to develop a prototype development environment and platform for safety-critical software for embedded applications. There are three core constituents: A profile of the Java programming language that is tailored for safety......-critical applications, a predictable Java processor built with FPGA technology, and an Eclipse based application development environment that binds the profile and the platform together and provides analyses that help to provide evidence that can be used as part of a safety case. This paper summarizes key contributions...

  3. Development of palm-based reference materials for the quantification of fatty acids composition.

    Science.gov (United States)

    Tarmizi, Azmil Haizam Ahmad; Lin, Siew Wai; Kuntom, Ainie

    2008-01-01

    Characterisation of fatty acids composition of three palm-based reference materials was carried out through inter-laboratory proficiency tests. Twelve laboratories collaborated in these tests and the fatty acids compositions of palm oil, palm olein and palm stearin were determined by applying the MPOB Test Methods p3.4:2004 and p3.5:2004. Determination of consensus values and their uncertainties were based on the acceptable statistical agreement of results obtained from the collaborating laboratories. The consensus values and uncertainties (%) for each palm oil reference material produced are listed as follows : 0.20% (C12:0), 1.66+/-0.05% (C14:0), 43.39+/-0.39% (C16:0), 0.14+/-0.06% (C16:1), 3.90+/-0.11% (C18:0), 40.95+/-0.23% (C18:1), 9.68+/-0.21% (C18:2), 0.16+/-0.07% (C18:3) and 0.31+/-0.08% (C20:0) for fatty acids composition of palm oil; 0.23+/-0.04% (C12:0), 1.02+/-0.04% (C14:0), 39.66+/-0.19% (C16:0), 0.18+/-0.07% (C16:1), 3.81+/-0.04% (C18:0), 44.01+/-0.08% (C18:1), 10.73+/-0.08% (C18:2), 0.20+/-0.06% (C18:3) and 0.34+/-0.04% (C20:0) for fatty acids composition of palm olein; and 0.20% (C12:0), 1.14+/-0.05% (C14:0), 49.42+/-0.25% (C16:0), 0.16+/-0.08% (C16:1), 4.15+/-0.10% (C18:0), 36.14+/-0.77% (C18:1), 7.95+/-0.29% (C18:2), 0.11+/-0.07% (C18:3) and 0.30+/-0.08% (C20:0) for fatty acids composition of palm stearin.

  4. Retrospective Analysis of NIST Standard Reference Material 1450, Fibrous Glass Board, for Thermal Insulation Measurements.

    Science.gov (United States)

    Zarr, Robert R; Heckert, N Alan; Leigh, Stefan D

    2014-01-01

    Thermal conductivity data acquired previously for the establishment of Standard Reference Material (SRM) 1450, Fibrous Glass Board, as well as subsequent renewals 1450a, 1450b, 1450c, and 1450d, are re-analyzed collectively and as individual data sets. Additional data sets for proto-1450 material lots are also included in the analysis. The data cover 36 years of activity by the National Institute of Standards and Technology (NIST) in developing and providing thermal insulation SRMs, specifically high-density molded fibrous-glass board, to the public. Collectively, the data sets cover two nominal thicknesses of 13 mm and 25 mm, bulk densities from 60 kg·m(-3) to 180 kg·m(-3), and mean temperatures from 100 K to 340 K. The analysis repetitively fits six models to the individual data sets. The most general form of the nested set of multilinear models used is given in the following equation: [Formula: see text]where λ(ρ,T) is the predicted thermal conductivity (W·m(-1)·K(-1)), ρ is the bulk density (kg·m(-3)), T is the mean temperature (K) and ai (for i = 1, 2, … 6) are the regression coefficients. The least squares fit results for each model across all data sets are analyzed using both graphical and analytic techniques. The prevailing generic model for the majority of data sets is the bilinear model in ρ and T. [Formula: see text] One data set supports the inclusion of a cubic temperature term and two data sets with low-temperature data support the inclusion of an exponential term in T to improve the model predictions. Physical interpretations of the model function terms are described. Recommendations for future renewals of SRM 1450 are provided. An Addendum provides historical background on the origin of this SRM and the influence of the SRM on external measurement programs.

  5. Effective density of Aquadag and fullerene soot black carbon reference materials used for SP2 calibration

    Directory of Open Access Journals (Sweden)

    M. Gysel

    2011-12-01

    Full Text Available The mass and effective density of black carbon (BC particles generated from aqueous suspensions of Aquadag and fullerene soot was measured and parametrized as a function of their mobility diameter. The measurements were made by two independent research groups by operating a differential mobility analyser (DMA in series with an aerosol particle mass analyser (APM or a Couette centrifugal particle mass analyser (CPMA. Consistent and reproducible results were found in this study for different production lots of Aquadag, indicating that the effective density of these particles is a stable quantity and largely unaffected by differences in aerosol generation procedures and suspension treatments. The effective density of fullerene soot particles from one production lot was also found to be stable and independent of suspension treatments. Some differences to previous literature data were observed for both Aquadag and fullerene soot at larger particle diameters. Knowledge of the exact relationship between mobility diameter and particle mass is of great importance, as DMAs are commonly used to size-select particles from BC reference materials for calibration of single particle soot photometers (SP2, which quantitatively detect the BC mass in single particles.

  6. Effective density of Aquadag and fullerene soot black carbon reference materials used for SP2 calibration

    Directory of Open Access Journals (Sweden)

    M. Gysel

    2011-08-01

    Full Text Available The mass and effective density of black carbon (BC particles generated from aqueous suspensions of Aquadag and fullerene soot was measured and parametrized as a function of their mobility diameter. The measurements were made by two independent research groups by operating a differential mobility analyser (DMA in series with an aerosol particle mass analyser (APM or a Couette centrifugal particle mass analyser (CPMA. Consistent and reproducible results were found in this study for different production lots of Aquadag, indicating that the effective density of these particles is a stable quantity and largely unaffected by differences in aerosol generation procedures and suspension treatments. The effective density of fullerene soot particles from one production lot was also found to be stable and independent of suspension treatments. Some difference to previous literature data was observed for both Aquadag and fullerene soot at larger particle diameters. Knowledge of the exact relationship between mobility diameter and particle mass is of great importance, as DMAs are commonly used to size-select particles from BC reference materials for calibration of single particle soot photometers (SP2, which quantitatively detect the BC mass in single particles.

  7. Development of Lentivirus-Based Reference Materials for Ebola Virus Nucleic Acid Amplification Technology-Based Assays.

    Science.gov (United States)

    Mattiuzzo, Giada; Ashall, James; Doris, Kathryn S; MacLellan-Gibson, Kirsty; Nicolson, Carolyn; Wilkinson, Dianna E; Harvey, Ruth; Almond, Neil; Anderson, Robert; Efstathiou, Stacey; Minor, Philip D; Page, Mark

    2015-01-01

    The 2013-present Ebola virus outbreak in Western Africa has prompted the production of many diagnostic assays, mostly based on nucleic acid amplification technologies (NAT). The calibration and performance assessment of established assays and those under evaluation requires reference materials that can be used in parallel with the clinical sample to standardise or control for every step of the procedure, from extraction to the final qualitative/quantitative result. We have developed safe and stable Ebola virus RNA reference materials by encapsidating anti sense viral RNA into HIV-1-like particles. The lentiviral particles are replication-deficient and non-infectious due to the lack of HIV-1 genes and Envelope protein. Ebola virus genes were subcloned for encapsidation into two lentiviral preparations, one containing NP-VP35-GP and the other VP40 and L RNA. Each reference material was formulated as a high-titre standard for use as a calibrator for secondary or internal standards, and a 10,000-fold lower titre preparation to serve as an in-run control. The preparations have been freeze-dried to maximise stability. These HIV-Ebola virus RNA reference materials were suitable for use with in-house and commercial quantitative RT-PCR assays and with digital RT-PCR. The HIV-Ebola virus RNA reference materials are stable at up to 37°C for two weeks, allowing the shipment of the material worldwide at ambient temperature. These results support further evaluation of the HIV-Ebola virus RNA reference materials as part of an International collaborative study for the establishment of the 1st International Standard for Ebola virus RNA.

  8. Development of Reference Material for Measuring the Heat of Detonation of Non-ideal Explosive%一种非理想炸药爆热计量用标准物质的研制

    Institute of Scientific and Technical Information of China (English)

    王彩玲; 王堃; 冯晓军; 赵省向; 刁小强; 戴致鑫

    2012-01-01

    研制了以RDX、铝粉为主要成分的非理想炸药爆热计量用标准物质,采用方差分析方法考核了标准物质的均匀性,根据先密后疏原则检验了标准物质的稳定性,分别用恒温法和绝热法测定爆热值.在分析炸药标准物质标准值的误差来源和影响因素的基础上,评估了标准物质标准值的合成标准不确定度和扩展不确定度,得出标准物质的标准爆热值为(7535.4±77.2)J/g,合成标准不确定度38.6J/g.结果表明,非理想炸药爆热用标准物质特性量值准确、可靠,均匀性和稳定性好,能够满足非理想炸药爆热量值传递的需要,达到校准和检定非理想炸药爆热测试仪器的要求.%A reference material,mainly composed of RDX and Al.was developed for verifying calorimeter used to determine the heat of detonation of non-ideal explosive. The homogeneity of characteristic value of the reference materials tested by means of the variance analysis method and its stability has been examined in regular order. The value of the heat of detonation was tested by an adiabatic calorimeter and a constant-temperature calorimeter respectively. The combined standard uncertainty and expanded uncertainty of standard value of reference material are evaluated,on the basis of analyzing the error source and factors affecting the standard value of the heat of detonation of reference material. The heat of detonation of reference material is (7535. 4±7. 2)J/g and the conbined standard uncertainty is 38. 6 J/g. The results indicate that the reference material has good homogeneity and stability,and accurate and reliable characteristic value,and can meet the requirements of transferring the certified value of heat of detonation and calibrating and verifying the calorimeter of heat of detonation of non-ideal explosive.

  9. Ten Reference Materials for Available Nutrients of Agricultural Soils%10个土壤有效态成分分析标准物质研制

    Institute of Scientific and Technical Information of China (English)

    刘妹; 顾铁新; 程志中; 黄宏库; 鄢卫东; 鄢明才

    2011-01-01

    Six nutrient-doped soil samples, used as reference materials, were prepared in 1998 but have been used up in the past 10 years. They played an important role in evaluation of soil productivity and ecological geochemistry. To satisfy surveys and evaluations in multi-purpose regional geochemistry and agricultural soil productivity, a series of ten new reference materials ( GBW07412a - GBW07417a, GBW07458 - GBW07461 ) were collected from the main agricultural regions of China and prepared by the Institute of Geophysical and Geochemical Exploration (IGGE ) at in 2009. Six of the ten samples were collected from the same sites as the six samples prepared in 1998, while the others four were collected from western China and calcareous. 50 indices, including nutritious and heavy metal elements, have been certified for all ten materials. These reference materials are more comprehensive and have been more widely distributed than the materials prepared in 1998. Furthermore, to eliminate the influence of analytical method differences in some indices between agricultural and forestry departments, methods of analysis and pretreatment were comprehensively discussed and unified by 13 laboratories from Ministry of Agriculture, Ministry of Land and Resources and Chinese Academy of Sciences.%首批6个土壤有效态成分分析标准物质( GBW07412~ GBW07417),在土壤地力评价和生态农业环境地球化学评价中发挥了重要作用,经十年广泛应用,现已用尽.为满足我国覆盖区多目标地球化学调查与评价及农业土壤地力调查与评价有效态化学成分测试质量监控的需求,2009年中国地质科学院地球物理地球化学勘查研究所研制了新系列土壤有效态成分分析标准物质(GBW07412a~GBW07417a,GBW07458 ~ GBW07461).该系列10个标准物质在原有6个样品采集地重新采集的基础上,新增的4个样品侧重于西部地区和石灰性土壤,使得新研制的有效态成分分析标准物质地域

  10. Comparison of a static and a dynamic in vitro model to estimate the bioaccessibility of As, Cd, Pb and Hg from food reference materials Fucus sp. (IAEA-140/TM) and Lobster hepatopancreas (TORT-2)

    Energy Technology Data Exchange (ETDEWEB)

    Torres-Escribano, Silvia [Instituto de Agroquimica y Tecnologia de Alimentos (IATA-CSIC), Apdo. 73, 46100, Burjassot, Valencia (Spain); Denis, Sylvain; Blanquet-Diot, Stephanie [Clermont Universite, Universite d' Auvergne, Centre de Recherche en Nutrition Humaine Auvergne, ERT 18, Conception ingenierie et developpement de l' aliment et du medicament, BP 10448, F-63000 Clermont-Ferrand (France); Calatayud, Marta [Instituto de Agroquimica y Tecnologia de Alimentos (IATA-CSIC), Apdo. 73, 46100, Burjassot, Valencia (Spain); Barrios, Laura [Departamento de Informatica Cientifica (SGAI-CSIC), C/ Pinar 19, 28006 Madrid (Spain); Velez, Dinoraz, E-mail: deni@iata.csic.es [Instituto de Agroquimica y Tecnologia de Alimentos (IATA-CSIC), Apdo. 73, 46100, Burjassot, Valencia (Spain); Alric, Monique [Clermont Universite, Universite d' Auvergne, Centre de Recherche en Nutrition Humaine Auvergne, ERT 18, Conception ingenierie et developpement de l' aliment et du medicament, BP 10448, F-63000 Clermont-Ferrand (France); Montoro, Rosa [Instituto de Agroquimica y Tecnologia de Alimentos (IATA-CSIC), Apdo. 73, 46100, Burjassot, Valencia (Spain)

    2011-01-01

    Bioaccessibility, the fraction of an element solubilized during gastrointestinal digestion and available for absorption, is a factor that should be considered when evaluating the health risk of contaminants from food. Static and dynamic models that mimic human physiological conditions have been used to evaluate bioaccessibility. This preliminary study compares the bioaccessibility of arsenic (As), cadmium (Cd), lead (Pb) and mercury (Hg) in two food certified reference materials (CRMs) (seaweed: Fucus sp., IAEA-140/TM; Lobster hepatopancreas: TORT-2), using two in vitro gastrointestinal digestion methods: a static method (SM) and a dynamic multicompartment method (TIM-1). There are significant differences (p < 0.05) between the bioaccessible values of As, Cd, Pb and Hg obtained by SM and TIM-1 in the two CRMs. The specific form in which the elements studied are present in the CRM may help to explain the bioaccessibility values obtained. - Research Highlights: {yields}Data are reported for As, Cd, Pb and Hg bioaccessibility from food CRMs. {yields}The static and TIM-1 methods give significantly different bioaccessibility values. {yields}The possible influence of speciation on bioaccessibility is discussed. {yields}To improve bioaccessibility quality data, food reference materials are needed.

  11. 废汽车尾气净化催化剂分析用标准样品的研制%Development of Reference Materials of Waste Autocatalysts for Analysis

    Institute of Scientific and Technical Information of China (English)

    任传婷; 方卫; 李青; 马媛; 游刚; 毕向光; 余建民

    2014-01-01

    The composition and the property values of Pt, Pd, Rh for waste autocatalysts were designed based on the current market demand. The process flow for reference material development, and the homogeneity and stability were tested in present study. Characterization analysis and value traceability are made for the materials prepared. According to variance analysis, the materials are homogeneous for Pt, Pd, Rh.t-testing results indicated that the well-prepared samples stored under the normal conditions are stable. The samples are collaboratively certified by ICP-AES, spectrophotometry and flame atomic absorption spectrometry. The certified values for Pt, Pd, Rh are obtained, and the uncertainty for Pt, Pd, Rh are evaluated. The reference material provides a basis for calibrating the instruments, evaluating measurement methods, training Staff or assigning to other materials.%根据目前市场需求,设计了废汽车尾气净化催化剂分析用标准样品的组成及特性值Pt、Pd、Rh 含量范围,建立了标准样品的制备工艺流程,对制备的标准样品进行了均匀性和稳定性检验、定值分析及量值溯源。经检验,均匀性符合要求;经t检验,在正常的保存条件下样品是稳定的。采用ICP-AES法、分光光度法及火焰原子吸收光谱法对样品进行协作定值,确定了Pt、Pd、Rh的标准特性值并对其不确定度进行了评估。制备得到的标准样品,可作为废汽车尾气净化催化剂分析过程中仪器校准、测量方法评价、人员培训或给其它材料赋值等诸项工作提供依据。

  12. 苦杏仁苷纯度标准物质研制和纯度标准值及不确定度分析方法研究%Research on Value Assignment and Uncertainty Evaluation of Purity Reference Material of Amygdalin

    Institute of Scientific and Technical Information of China (English)

    周政政; 郭永辉; 杨德智; 吕扬

    2013-01-01

    Objective To develop the purity certified reference material of amygdalin which has traceability, value transmission and high-accuracy quantity value, and to establish an accurate definite value analytical method. Methods The purity value of purity certified reference material of amygdalin was determined by combined value assignment of high performance liquid chromatography ( HPLC) area normalization method and differential scanning calorimetry (DSC) on the basis of Technical Norm of Primary Reference Material and related documents requirements. Results The developed purity certified reference material of amygdalin was in accordance with Technical Norm of Primary Reference Material requirements and the standard value and uncertainty was (99.3±0.4)% (k = 2, P = 0. 95). Conclusion The combined different principles analytical technology method could overcome the defects of one method and guarantee for the accurate value assignment results of the purity reference material of amygdalin in this study and it was an internationally accepted National Certified Reference Material which could provide reference material, material standard and scientific foundation of standard method for the international competition of related medicines.%目的 研制具有溯源性、具备量值传递功能、高准确度量值的苦杏仁苷高纯度国家级有证标准物质,建立准确定量的定值分析方法.方法 根据我国一级标准物质研制技术规范和国家计量相关法规要求,建立基于高效液相色谱(HPLC)面积归一化法和差示扫描量热法(DSC)的两种不同原理技术的苦杏仁苷纯度标准物质的标准值及不确定度评估联合定值方法.结果 研制的苦杏仁苷纯度标准物质符合国家一级有证标准物质技术要求,其标准值及不确定度值为(99.3 ±0.4)%(k=2,P=0.95).结论 采用不同原理技术方法定值可有效克服一种技术的缺陷影响,保证苦杏仁苷纯度标准物质定值结果准确,

  13. 24 CFR 1710.504 - Cooperation among certified states and between certified states and the Secretary.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Cooperation among certified states....504 Cooperation among certified states and between certified states and the Secretary. (a) By filing... exceed the federal standard provided that such requirements are not in conflict with the Act or...

  14. 40 CFR 1060.810 - What materials does this part reference?

    Science.gov (United States)

    2010-07-01

    ... material. Table 2 to this section lists material from the Society of Automotive Engineers that we have... the Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096 or http://www.sae.... (a) ASTM material. Table 1 to this section lists material from the American Society for Testing...

  15. Preparation of Quartzite Reference Materials for Chemical Composition Analysis%石英岩化学成分分析标准物质研制

    Institute of Scientific and Technical Information of China (English)

    刘調; 马玲; 时晓露; 查立新

    2014-01-01

    At present,quartzitic reference materials are prepared by Brazil,England,Japan,and South Africa but are not in series. The SiO2 contents in these reference materials are generally above 96% and accurate concentration values are determined for only small number of elements.To date,no quartzitic reference material has been prepared in China,which cannot meet the demand of quartzite exploration and practical applications.In this study,three quartzitic reference materials were developed with samples from representative quartz mining areas,namely Damiao Town, Fengyang County, Anhui Province;Jingyang Town, Datong County, Qinghai Province;and Lingqiu mountain,Qichun County,Hubei Province.The samples were finely crushed to -45 μm with a fluidized bed-type airflow crusher to prevent sample contamination.Homogeneity and stability testing was conducted chiefly by Inductively Coupled Plasma-Atomic Emission Spectrometry and Inductively Coupled Plasma-Mass Spectrometry rather than X-ray Fluorescence Spectrometry with tablet sample preparation,which results in the quartzite material being difficult to mould.F values for the variance test were less than the threshold,which indicated a good homogeneity.No significant statistical changes were observed in eight two-year stability tests.The short-term stability analysis in the condition of extreme temperatures and vibration were also consistent.Determined values were certified by 1 0 laboratories in China with multiple methods.For components without homogeneity and stability tests,values and relative uncertainty of 36 components were obtained by comparing similar elements.The three quartzitic reference materials have been approved as national standard reference materials (GBW 07835 , GBW07836 and GBW 07837),with 92.93%,95.97% and 99.18% of SiO2,respectively,as a gradient distributed series.The series of reference materials has the characteristics of uniform grading,narrow diameter distribution (D25 -D75 ranged between 4 -1 6

  16. Development of working reference materials of copper ore material%铜矿石二级标准物质的研制

    Institute of Scientific and Technical Information of China (English)

    梅连平; 云天化

    2011-01-01

    介绍了铜矿石二级标准物质的研制方法.进行了均匀性检验和稳定性检验并对其定值,结果显示该二级标准物质均匀性和稳定性以及定值准确性均达到国家标准物质的性能指标,符合国家计量技术规范的要求.%This paper introduced the development of working reference materials of copper ore material through the uniformity and stability testing and value definiting.The results showed that this working reference material's uniformity, stability and the accuracy of fixed value have reached the performance index of national standard materials, which have been up to the national metrological verification technical specification's requirements.

  17. Preparation and characterisation of in-house reference material of tylosin in honey and results of a proficiency test.

    Science.gov (United States)

    Bohm, Detlef A; Stachel, Carolin S; Hackenberg, Rudolf; Gowik, Petra

    2011-08-26

    The analysis of incurred material from animals treated with pharmacologically active substances is an efficient way to check the accuracy of a method. Tylosin A was chosen for the preparation of that material because it is highly effective in controlling active infections of American Foulbrood (AFB), a global threat to apiculture, but residues in honey are not allowed according to European legislation. For this reason an in-house reference material of honey containing the macrolide tylosin A and its degradation product desmycosin (tylosin B) was prepared. After the treatment of a beehive with the appropriate macrolide tylosin A, the honey samples were collected. The incurred honey material was diluted by mixing with blank honey. Concentrations of 25.81 μg kg(-1) for tylosin A and of 19.28 μg kg(-1) for its degradation product desmycosin (tylosin B) were reached. The homogeneity was checked by analysing 12 bottles in duplicate. The stability was tested at different defined temperatures and storage conditions. The reference material described above was homogeneous and stable. Samples of this in-house reference material were used for the realisation of a proficiency test with international participation. All participants accomplished satisfying results with the exception of one laboratory.

  18. Application of direct solid sample analysis for the determination of chlorine in biological materials using electrothermal vaporization inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Santos de Gois, Jefferson; Pereira, Éderson R. [Departamento de Química, Universidade Federal de Santa Catarina, 88040-970 Florianópolis, SC (Brazil); Welz, Bernhard [Departamento de Química, Universidade Federal de Santa Catarina, 88040-970 Florianópolis, SC (Brazil); INCT de Energia e Ambiente do CNPq (Brazil); Borges, Daniel L.G., E-mail: daniel.borges@ufsc.br [Departamento de Química, Universidade Federal de Santa Catarina, 88040-970 Florianópolis, SC (Brazil); INCT de Energia e Ambiente do CNPq (Brazil)

    2015-03-01

    This work describes a methodology developed to carry out Cl determination in biological materials using electrothermal vaporization inductively coupled plasma mass spectrometry and direct solid sample analysis. The solid samples were directly weighed into graphite ‘cups’ and inserted into the graphite furnace. The RF power and the carrier gas flow rate were optimized at 1300 W and 0.7 L min{sup −1}, respectively. Calibration could be carried out using aqueous standard solutions with pre-dried modifiers (Pd + Nd or Pd + Ca) or using solid certified reference materials with the same pre-dried modifiers or without the use of modifiers. The limit of quantification was determined as 5 μg g{sup −1} under optimized conditions and the Cl concentration was determined in five certified reference materials with certified concentrations for Cl, in addition to three certified reference materials, for which certified values for Cl were unavailable; in the latter case, the results were compared with those obtained using high-resolution continuum source molecular absorption spectrometry. Good agreement at a 95% statistical confidence level was achieved between determined and certified or reference values. - Highlights: • Direct determination of chlorine in solid biological materials is described for the first time using ICP-MS. • Calibration against aqueous standards is feasible. • The method is accurate and sensitive, regardless of the composition of the solid sample.

  19. Doorways II: Community Counselor Reference Materials. On School-Related Gender-Based Violence Prevention and Response

    Science.gov (United States)

    US Agency for International Development, 2009

    2009-01-01

    The Doorways training program was designed by the U.S. Agency for International Development (USAID)-funded Safe Schools Program (Safe Schools) to enable teachers, community members and students to prevent and respond to school-related gender-based violence (SRGBV). This booklet, "Doorways II: Community Counselor Reference Materials on…

  20. Development of a genomic DNA reference material panel for myotonic dystrophy type 1 (DM1) genetic testing.

    Science.gov (United States)

    Kalman, Lisa; Tarleton, Jack; Hitch, Monica; Hegde, Madhuri; Hjelm, Nick; Berry-Kravis, Elizabeth; Zhou, Lili; Hilbert, James E; Luebbe, Elizabeth A; Moxley, Richard T; Toji, Lorraine

    2013-07-01

    Myotonic dystrophy type 1 (DM1) is caused by expansion of a CTG triplet repeat in the 3' untranslated region of the DMPK gene that encodes a serine-threonine kinase. Patients with larger repeats tend to have a more severe phenotype. Clinical laboratories require reference and quality control materials for DM1 diagnostic and carrier genetic testing. Well-characterized reference materials are not available. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the genetic testing community, the National Registry of Myotonic Dystrophy and Facioscapulohumeral Muscular Dystrophy Patients and Family Members, and the Coriell Cell Repositories, has established and characterized cell lines from patients with DM1 to create a reference material panel. The CTG repeats in genomic DNA samples from 10 DM1 cell lines were characterized in three clinical genetic testing laboratories using PCR and Southern blot analysis. DMPK alleles in the samples cover four of five DM1 clinical categories: normal (5 to 34 repeats), mild (50 to 100 repeats), classical (101 to 1000 repeats), and congenital (>1000 repeats). We did not identify or establish Coriell cell lines in the premutation range (35 to 49 repeats). These samples are publicly available for quality control, proficiency testing, test development, and research and should help improve the accuracy of DM1 testing.

  1. Development of a reference material for Staphylococcus aureus enterotoxin A in cheese: feasibility study, processing, homogeneity and stability assessment.

    Science.gov (United States)

    Zeleny, R; Emteborg, H; Charoud-Got, J; Schimmel, H; Nia, Y; Mutel, I; Ostyn, A; Herbin, S; Hennekinne, J-A

    2015-02-01

    Staphylococcal food poisoning is caused by enterotoxins excreted into foods by strains of staphylococci. Commission Regulation 1441/2007 specifies thresholds for the presence of these toxins in foods. In this article we report on the progress towards reference materials (RMs) for Staphylococcal enterotoxin A (SEA) in cheese. RMs are crucial to enforce legislation and to implement and safeguard reliable measurements. First, a feasibility study revealed a suitable processing procedure for cheese powders: the blank material was prepared by cutting, grinding, freeze-drying and milling. For the spiked material, a cheese-water slurry was spiked with SEA solution, freeze-dried and diluted with blank material to the desired SEA concentration. Thereafter, batches of three materials (blank; two SEA concentrations) were processed. The materials were shown to be sufficiently homogeneous, and storage at ambient temperature for 4weeks did not indicate degradation. These results provide the basis for the development of a RM for SEA in cheese.

  2. NAVAIR Portable Source Initiative (NPSI) Standard for Material Properties Reference Database (MPRD) V2.2

    Science.gov (United States)

    2012-09-26

    Shrub  Forb  Vine  Graminoid  Cactus  Fern  Lichen  Bryophyte MPRD Material Library is conceptually organized as a conventional library...title, revision history , and other administrative information (contact info, licensing, security, etc.) Material element contains the material...Dictionary_Header is the document header containing document title, revision history , and other administrative information (contact info, licensing

  3. Determination of sodium and potassium in certified rock samples by AES after ultrasonic leaching

    Directory of Open Access Journals (Sweden)

    AYSUN ÖZKAN

    2006-09-01

    Full Text Available In order to evaluate the data obtained by atomic emission spectrometric analysis after ultrasonic extraction, destructive analysis of some certified rock samples employing ultrasonic waves was applied to two elements, Na and K, and the recovery rates were defined. The recovery ratio as K1 = CULM/CCRM was defined for the ultrasonic leaching method (CULM and the certified reference materials (CRMs. Another recovery ratio, K2 was also defined from the results of the conventional dissolution method (CCDM, that is K2, CULM/CCDM. The accuracy and precision of the method were comparable with those of the conventional methods. The obtained recoveries were between 90.0 % < K1,Na < 106.1 and 90.0 % < K2,Na < 103.0 % for Na and 92.3 % < K1,K < 103.2 and 92.3% < K2,K < 104.5% for K. It was shown that ultrasonic extraction can be effectively used for analytical sample preparation purposes.

  4. Monazite RW-1: a homogenous natural reference material for SIMS U-Pb and Th-Pb isotopic analysis

    Science.gov (United States)

    Ling, Xiao-Xiao; Huyskens, Magdalena H.; Li, Qiu-Li; Yin, Qin-Zhu; Werner, Ronald; Liu, Yu; Tang, Guo-Qiang; Yang, Ya-Nan; Li, Xian-Hua

    2016-10-01

    Well-characterized matrix-matched natural mineral references of known age are an important prerequisite for SIMS (secondary ion mass spectrometry) U-Th-Pb dating. We have characterized RW-1, a 44 g yellowish-brown single monazite specimen from a Norwegian pegmatite as an excellent hi-Th reference material for secondary ion mass spectrometric U-Th-Pb dating. A total of 206 secondary ion mass spectrometric analyses over six analytical sessions were performed on different monazite fragments of RW-1. The analyses resulted in 207Pb-based common lead corrected 206Pb/238U ages and Th-Pb ages with overall 2 % (2 SD = standard deviation) variations, indicating the good U-Th-Pb system homogeneity. The homogeneity of Th content of 11.8 ± 1.0 wt% (2 SD) and Th/U of 42 ± 3 (2 SD) make this crystal also a good compositional reference material. We used the combined ID-TIMS(Pb)/ID-MC-ICP-MS(U) technique (i.e. isotope dilution thermal ionization mass spectrometry for Pb, and isotope dilution multi-collector inductively-coupled plasma mass spectrometry for U) to determine U-Pb ages of the monazite samples studied. The mean 207Pb/235U age of 904.15 ± 0.26 Ma (95 % confidence level) is recommended as the best estimate crystallization age for RW-1 monazite. Considering that the most commonly distributed U-Pb monazite reference materials have rather low ThO2, we suggest that this RW-1 monazite with its ThO2 of 13.5 wt% is a suitable reference material providing investigators more confidence when dating high-Th monazite unknowns.

  5. Preparation of two biological reference materials for QUASIMEME inter-laboratory testing

    NARCIS (Netherlands)

    Lohman, M.; Korytar, P.

    2007-01-01

    Two biological materials have been prepared for the Institute for Environmental Studies (IVM), Free University, Amsterdam to be used in QUASIMEME interlaboratory studies. The materials prepared are: 300 tins of homogenized blue mussels from the Waddenzee (QO07-1) and 300 tins of homogenized shrimps

  6. ENERGY STAR Certified Commercial Clothes Washers

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 7.0 ENERGY STAR Program Requirements for Clothes Washers that are effective as of March...

  7. ENERGY STAR Certified Light Commercial HVAC

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 2.0 ENERGY STAR Program Requirements for Light Commercial HVAC that are effective as of...

  8. ENERGY STAR Certified Commercial Refrigerators and Freezers

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 3.0 ENERGY STAR Program Requirements for Commercial Refrigerators and Freezers that are...

  9. ENERGY STAR Certified Data Center Storage

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 1.0 ENERGY STAR Program Requirements for Data Center Storage that are effective as of...

  10. ENERGY STAR Certified Geothermal Heat Pumps

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 3.0 ENERGY STAR Program Requirements for Geothermal Heat Pumps that are effective as of...

  11. ENERGY STAR Certified Residential Clothes Dryers

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 1.0 ENERGY STAR Program Requirements for Clothes Dryers that are effective as of January...

  12. HISTORIC ENERGY STAR Certified Room Air Cleaners

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 1.2 ENERGY STAR Program Requirements for Room Air Cleaners that are effective as of July...

  13. Comprehensive Pb-Sr-Nd-Hf isotopic, trace element, and mineralogical characterization of mafic to ultramafic rock reference materials

    Science.gov (United States)

    Fourny, Anaïs.; Weis, Dominique; Scoates, James S.

    2016-03-01

    Controlling the accuracy and precision of geochemical analyses requires the use of characterized reference materials with matrices similar to those of the unknown samples being analyzed. We report a comprehensive Pb-Sr-Nd-Hf isotopic and trace element concentration data set, combined with quantitative phase analysis by XRD Rietveld refinement, for a wide range of mafic to ultramafic rock reference materials analyzed at the Pacific Centre for Isotopic and Geochemical Research, University of British Columbia. The samples include a pyroxenite (NIM-P), five basalts (BHVO-2, BIR-1a, JB-3, BE-N, GSR-3), a diabase (W-2), a dolerite (DNC-1), a norite (NIM-N), and an anorthosite (AN-G); results from a leucogabbro (Stillwater) are also reported. Individual isotopic ratios determined by MC-ICP-MS and TIMS, and multielement analyses by HR-ICP-MS are reported with 4-12 complete analytical duplicates for each sample. The basaltic reference materials have coherent Sr and Nd isotopic ratios with external precision below 50 ppm (2SD) and below 100 ppm for Hf isotopes (except BIR-1a). For Pb isotopic reproducibility, several of the basalts (JB-3, BHVO-2) require acid leaching prior to dissolution. The plutonic reference materials also have coherent Sr and Nd isotopic ratios (<50 ppm), however, obtaining good reproducibility for Pb and Hf isotopic ratios is more challenging for NIM-P, NIM-N, and AN-G due to a variety of factors, including postcrystallization Pb mobility and the presence of accessory zircon. Collectively, these results form a comprehensive new database that can be used by the geochemical community for evaluating the radiogenic isotope and trace element compositions of volcanic and plutonic mafic-ultramafic rocks.

  14. Material investigation for manufacturing of reference step gauges for CT scanning verification

    DEFF Research Database (Denmark)

    Cantatore, Angela; Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    2012-01-01

    This work deals with the study of stability and material investigation for manufacturing of step gauges for CT scanning verification. Four replica step gauges were fabricated using a bisacryl material for dental applications and the stability over five months was monitored using a tactile CMM....... The material was unstable, probably due to a modification of the chemical composition which lowered the hardness. New step gauges were manufactured through milling. Polyetheretherketone (PEEK) and Polyp-phenylenesulphide (PPS with 40% glass) fulfil the requirements regarding hardness and mechanical properties...... and two series of five step gauges (one series for each material) were manufactured by milling. Results show a significant improvement in terms of form stability and surface geometry quality of the new step gauges with respect to the replica step gauges in Luxabite, as reported below....

  15. A pointer logic and certifying compiler

    Institute of Scientific and Technical Information of China (English)

    CHEN Yiyun; GE Lin; HUA Baojian; LI Zhaopeng; LIU Cheng; WANG Zhifang

    2007-01-01

    Proof-Carrying Code brings two big challenges to the research field of programming languages.One is to seek more expressive logics or type systems to specify or reason about the properties of low-level or high-level programs.The other is to study the technology of certifying compilation in which the compiler generates proofs for programs with annotations.This paper presents our progress in the above two aspects.A pointer logic was designed for PointerC (a C-like programming language) in our research.As an extension of Hoare logic,our pointer logic expresses the change of pointer information for each statement in its inference rules to support program verification.Meanwhile,based on the ideas from CAP (Certified Assembly Programming) and SCAP (Stack-based Certified Assembly Programming),a reasoning framework was built to verify the properties of object code in a Hoare style.And a certifying compiler prototype for PointerC was implemented based on this framework.The main contribution of this paper is the design of the pointer logic and the implementation of the certifying compiler prototype.In our certifying compiler,the source language contains rich pointer types and operations and also supports dynamic storage allocation and deallocation.

  16. Comprehensive inter-laboratory calibration of reference materials for d18O versus VSMOW using various on-line high-temperature conversion techniques

    Science.gov (United States)

    Coplen, Tyler B.; Bohlke, Johnkarl F.; Mroczkowski, Stanley J.; Qi, Haiping; Brand, Willi A.; Aerts-Bijma, Anita T.; Gehre, Matthias; Geilmann, Heike; Groning, Manfred

    2009-01-01

    "Internationally distributed organic and inorganic oxygen isotopic reference materials have been calibrated by six laboratories carrying out more than 5300 measurements using a variety of high-temperature conversion techniques (HTC) in an evaluation sponsored by the International Union of Pure and Applied Chemistry (IUPAC). To aid in the calibration of these reference materials, which span more than 125‰, an artificially enriched reference water (d18O of +78.91‰) and two barium sulfates (one depleted and one enriched in 18O) were prepared and calibrated relative to VSMOW2 and SLAP reference waters. These materials were used to calibrate the other isotopic reference materials in this study, which yielded: Reference material d18O and estimated combined uncertainty

  17. Comprehensive inter-laboratory calibration of reference materials for δ18O versus VSMOW using various on-line high-temperature conversion techniques

    Science.gov (United States)

    Brand, Willi A.; Coplen, Tyler B.; Aerts-Bijma, Anita T.; Böhlke, J.K.; Gehre, Matthias; Geilmann, Heike; Groning, Manfred; Jansen, Henk G.; Meijer, Harro A. J.; Mroczkowski, Stanley J.; Qi, Haiping; Soergel, Karin; Stuart-Williams, Hilary; Weise, Stephan M.; Werner, Roland A.

    2009-01-01

    Internationally distributed organic and inorganic oxygen isotopic reference materials have been calibrated by six laboratories carrying out more than 5300 measurements using a variety of high-temperature conversion techniques (HTC)a in an evaluation sponsored by the International Union of Pure and Applied Chemistry (IUPAC). To aid in the calibration of these reference materials, which span more than 125‰, an artificially enriched reference water (δ18O of +78.91‰) and two barium sulfates (one depleted and one enriched in 18O) were prepared and calibrated relative to VSMOW2b and SLAP reference waters. These materials were used to calibrate the other isotopic reference materials in this study, which yielded: Reference materialδ18O and estimated combined uncertainty c IAEA-602 benzoic acid

  18. Marine mammal blubber reference and control materials for use in the determination of halogenated organic compounds and fatty acids

    Energy Technology Data Exchange (ETDEWEB)

    Kucklick, John R.; Pugh, Rebecca S.; Becker, Paul R. [Hollings Marine Laboratory, National Institute of Standards and Technology (NIST), Charleston, SC (United States); Schantz, Michele M.; Porter, Barbara J.; Poster, Dianne L.; Leigh, Stefan; Wise, Stephen A. [NIST, Analytical Chemistry Division, Gaithersburg, MD (United States); Rowles, Teri K. [National Marine Fisheries Service, National Oceanic and Atmospheric Administration, Silver Spring, MD (United States)

    2010-05-15

    The National Institute of Standards and Technology (NIST) has a diverse collection of control materials derived from marine mammal blubber, fat, and serum. Standard Reference Material (SRM) 1945 Organics in Whale Blubber was recertified for polychlorinated biphenyl (PCB) congeners, organochlorine pesticides, and polybrominated diphenyl ether (PBDE) congeners. SRM 1945 has also been assigned mass fraction values for compounds not frequently determined in marine samples including toxaphene congeners, coplanar PCBs, and methoxylated PBDE congeners which are natural products. NIST also has assigned mass fraction values, as a result of interlaboratory comparison exercises, for PCB congeners, organochlorine pesticides, PBDE congeners, and fatty acids in six homogenate materials produced from marine mammal blubber or serum. The materials are available from NIST upon request; however, the supply is very limited for some of the materials. The materials include those obtained from pilot whale blubber (Homogenates III and IV), Blainville's beaked whale blubber (Homogenate VII), polar bear fat (Homogenate VI), and California sea lion serum (Marine Mammal Control Material-1 Serum) and blubber (Homogenate V). (orig.)

  19. 7 CFR 201.69 - Classes of certified seed.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Classes of certified seed. 201.69 Section 201.69..., Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) FEDERAL SEED ACT FEDERAL SEED ACT REGULATIONS Certified Seed § 201.69 Classes of certified seed. (a) Classes of certified seed are as...

  20. 7 CFR 945.7 - Certified seed potatoes.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Certified seed potatoes. 945.7 Section 945.7... Certified seed potatoes. Certified seed potatoes means and includes all potatoes officially certified and tagged, marked, or otherwise appropriately identified, under the supervision of the official seed...

  1. Iron Disilicide as High-Temperature Reference Material for Traceable Measurements of Seebeck Coefficient Between 300 K and 800 K

    Science.gov (United States)

    Ziolkowski, Pawel; Stiewe, Christian; de Boor, Johannes; Druschke, Ines; Zabrocki, Knud; Edler, Frank; Haupt, Sebastian; König, Jan; Mueller, Eckhard

    2017-01-01

    Thermoelectric generators (TEGs) convert heat to electrical energy by means of the Seebeck effect. The Seebeck coefficient is a central thermoelectric material property, measuring the magnitude of the thermovoltage generated in response to a temperature difference across a thermoelectric material. Precise determination of the Seebeck coefficient provides the basis for reliable performance assessment in materials development in the field of thermoelectrics. For several reasons, measurement uncertainties of up to 14% can often be observed in interlaboratory comparisons of temperature-dependent Seebeck coefficient or in error analyses on currently employed instruments. This is still too high for an industrial benchmark and insufficient for many scientific investigations and technological developments. The TESt (thermoelectric standardization) project was launched in 2011, funded by the German Federal Ministry of Education and Research (BMBF), to reduce measurement uncertainties, engineer traceable and precise thermoelectric measurement techniques for materials and TEGs, and develop reference materials (RMs) for temperature-dependent determination of the Seebeck coefficient. We report herein the successful development and qualification of cobalt-doped β-iron disilicide ( β-Fe0.95Co0.05Si2) as a RM for high-temperature thermoelectric metrology. A brief survey on technological processes for manufacturing and machining of samples is presented. Focus is placed on metrological qualification of the iron disilicide, results of an international round-robin test, and final certification as a reference material in accordance with ISO-Guide 35 and the "Guide to the expression of uncertainty in measurement" by the Physikalisch-Technische Bundesanstalt, the national metrology institute of Germany.

  2. Iron Disilicide as High-Temperature Reference Material for Traceable Measurements of Seebeck Coefficient Between 300 K and 800 K

    Science.gov (United States)

    Ziolkowski, Pawel; Stiewe, Christian; de Boor, Johannes; Druschke, Ines; Zabrocki, Knud; Edler, Frank; Haupt, Sebastian; König, Jan; Mueller, Eckhard

    2016-09-01

    Thermoelectric generators (TEGs) convert heat to electrical energy by means of the Seebeck effect. The Seebeck coefficient is a central thermoelectric material property, measuring the magnitude of the thermovoltage generated in response to a temperature difference across a thermoelectric material. Precise determination of the Seebeck coefficient provides the basis for reliable performance assessment in materials development in the field of thermoelectrics. For several reasons, measurement uncertainties of up to 14% can often be observed in interlaboratory comparisons of temperature-dependent Seebeck coefficient or in error analyses on currently employed instruments. This is still too high for an industrial benchmark and insufficient for many scientific investigations and technological developments. The TESt (thermoelectric standardization) project was launched in 2011, funded by the German Federal Ministry of Education and Research (BMBF), to reduce measurement uncertainties, engineer traceable and precise thermoelectric measurement techniques for materials and TEGs, and develop reference materials (RMs) for temperature-dependent determination of the Seebeck coefficient. We report herein the successful development and qualification of cobalt-doped β-iron disilicide (β-Fe0.95Co0.05Si2) as a RM for high-temperature thermoelectric metrology. A brief survey on technological processes for manufacturing and machining of samples is presented. Focus is placed on metrological qualification of the iron disilicide, results of an international round-robin test, and final certification as a reference material in accordance with ISO-Guide 35 and the "Guide to the expression of uncertainty in measurement" by the Physikalisch-Technische Bundesanstalt, the national metrology institute of Germany.

  3. Assessment of Materialism and Reference Group Influence on Preference for Western Branded Fabrics in Maiduguri, Borno State, Nigeria

    Directory of Open Access Journals (Sweden)

    Mohammed Abba

    2013-01-01

    Full Text Available This paper investigates how materialism and reference group influence may affect consumers’ preference for western branded fabrics. Data for the study was collected through questionnaire administered on a sample of 26 respondents. The respondents were selected using convenient sampling through snowball from a population of male and female professional workers aged 18 and above. Data collected from the primary source (questionnaire was analyzed using simple percentage. Findings revealed that materialism had no significant influence on their preferences for western branded fabrics. Reference groups, however, significantly influenced respondents’ decision to purchase Western branded fabrics. It was concluded that although some of the behaviors of the sampled group were quite materialistic, they were not enhanced by associations with Western branded fabrics and their related cultural values. Based on the findings, it was recommended that marketers of western brands in Borno state, particularly in the state capital can do well if they adopt a strategy of deliberately targeting and nurturing of their consumers’ reference groups, rather than attempt to position their products on the basis of inherent materialistic values.

  4. Feasibility of the development of reference materials for the detection of Ag nanoparticles in food: neat dispersions and spiked chicken meat

    DEFF Research Database (Denmark)

    Grombe, Ringo; Allmaier, Günter; Charoud-Got, Jean;

    2015-01-01

    The feasibility of producing colloidal silver nanoparticle reference materials and silver nanoparticle spiked reference matrix materials was investigated. Two concentrations of PVP-coated silver nanoparticle dispersions were evaluated and used to spike chicken meat, with the aim of producing a se...

  5. Feasibility of the development of reference materials for the detection of Ag nanoparticles in food: neat dispersions and spiked chicken meat

    NARCIS (Netherlands)

    Grombe, R.; Allmaier, G.; Charoud-Got, J.; Dudkiewicz, A.; Emteborg, H.; Hofmann, T.; Huusfeldt-Larsen, E.; Lehner, A.; Llinas, M.; Loeschner, K.; Molhave, K.; Peters, R.J.B.; Seghers, J.; Solans, C.; Kammer, van den F.; Wagner, S.; Weigel, S.; Linsinger, T.P.J.

    2015-01-01

    The feasibility of producing colloidal silver nanoparticle reference materials and silver nanoparticle spiked reference matrix materials was investigated. Two concentrations of PVP-coated silver nanoparticle dispersions were evaluated and used to spike chicken meat, with the aim of producing a set o

  6. A Family of Reference Hugoniots for Two-phase Porous Materials

    Science.gov (United States)

    2015-06-01

    and strength of the material at these pressures (for detailed analysis, see [5, 6]). Nevertheless, even at low pressures the trend and behaviour of... behaviour of the Hugoniot is observed if phase temperatures are not in equilibrium and this occurs at higher pressures because the corresponding...analyse the Hugoniot behaviour , the present work employs simplest EOSs thermodynamically consistent with shock-wave compression. For the gaseous

  7. 甲苯中苯标准物质的研制%Development of reference material of benzene in toluene

    Institute of Scientific and Technical Information of China (English)

    张苏敏; 张毅; 代妍; 何丘

    2012-01-01

    以甲苯和苯为原料,采用称量-容量法研制了浓度为5 mg/mL的甲苯中苯溶液标准物质.所研制的标准物质通过均匀性检验、稳定性检验和与GBW(E) 130101的比对,标准值的相对扩展不确定度为3%(k=2),有效期限为24 m.%A kind of reference material of benzene in toluene was prepared using benzene and toluene as raw materials by Gravimetric-Volume Method. The standard value of concentration is 5 mg/mL. The reference material passed the homogeneity inspection, stability examination and intercomparison test between it and GBW(E) 130101. The relative expanded uncertainty of the concentration standard value is 3% (A = 2). The validity period is 24 m.

  8. Examples of reference material data needed for LBB analysis derived from WGCS-EC-DGXI studies

    Energy Technology Data Exchange (ETDEWEB)

    Petrequin, P.; Houssin, B.; Guinovart, J.

    1997-04-01

    Mechanical data collected through the sponsorship of the Activity Group 3 <<Materials>> of the Working Group Codes and Standards of DG XI European Commission are pointed out to illustrate their potential use for Leak Before Break analyses. Most of the tensile, fatigue, creep and fracture toughness data have been generated for stainless steels, mainly on modified type 316 L (N), selected for the Super Phoenix LMFBR. Trends for ongoing programs and future works on C-Mn and MnNiMo low alloy steels are provided.

  9. Improved efficiency of extraction of polycyclic aromatic hydrocarbons (PAHs) from the National Institute of Standards and Technology (NIST) Standard Reference Material Diesel Particulate Matter (SRM 2975) using accelerated solvent extraction.

    Science.gov (United States)

    Masala, Silvia; Ahmed, Trifa; Bergvall, Christoffer; Westerholm, Roger

    2011-12-01

    The efficiency of extraction of polycyclic aromatic hydrocarbons (PAHs) with molecular masses of 252, 276, 278, 300, and 302 Da from standard reference material diesel particulate matter (SRM 2975) has been investigated using accelerated solvent extraction (ASE) with dichloromethane, toluene, methanol, and mixtures of toluene and methanol. Extraction of SRM 2975 using toluene/methanol (9:1, v/v) at maximum instrumental settings (200 °C, 20.7 MPa, and five extraction cycles) with 30-min extraction times resulted in the following elevations of the measured concentration when compared with the certified and reference concentrations reported by the National Institute of Standards and Technology (NIST): benzo[b]fluoranthene, 46%; benzo[k]fluoranthene, 137%; benzo[e]pyrene, 103%; benzo[a]pyrene, 1,570%; perylene, 37%; indeno[1,2,3-cd]pyrene, 41%; benzo[ghi]perylene, 163%; and coronene, 361%. The concentrations of the following PAHs were comparable to the reference values assigned by NIST: indeno[1,2,3-cd]fluoranthene, dibenz[a,h]anthracene, and picene. The measured concentration of dibenzo[a,e]-pyrene was lower than the information value reported by the NIST. The measured concentrations of other highly carcinogenic PAHs (dibenzo[a,l]pyrene, dibenzo[a,i]pyrene, and dibenzo[a,h]pyrene) in SRM 2975 are also reported. Comparison of measurements using the optimized ASE method and using similar conditions to those applied by the NIST for the assignment of PAH concentrations in SRM 2975 indicated that the higher values obtained in the present study were associated with more complete extraction of PAHs from the diesel particulate material. Re-extraction of the particulate samples demonstrated that the deuterated internal standards were more readily recovered than the native PAHs, which may explain the lower values reported by the NIST. The analytical results obtained in the study demonstrated that the efficient extraction of PAHs from SRM 2975 is a critical requirement for the

  10. Comparative metal distribution in scalp hair of Pakistani and Irish referents and hypertensive patients.

    Science.gov (United States)

    Afridi, Hassan Imran; Brabazon, Dermot; Kazi, Tasneem Gul; Naher, Sumsun; Nesterenko, Ekaterina

    2011-12-01

    The abnormal metabolism of metal ions plays an important role in health and disease conditions, and studies about them have been attracting significant interest. The aim of our study was to assess the heavy metals (cadmium (Cd), nickel (Ni), lead (Pb), and zinc (Zn)) in scalp hair samples of 50 Irish and 78 Pakistani hypertensive patients of an urban population together with 50 Irish and 96 Pakistani non-hypertensive male subjects in the age group of 30-50 years. The concentrations of trace and toxic elements were measured by inductively coupled plasma-atomic emission spectrophotometer and atomic absorption spectrophotometer before microwave-assisted acid digestion. The validity and accuracy of the methodology were checked using certified reference materials, and by the conventional wet acid digestion method on the same certified reference materials and on real samples. The recovery of all the studied elements was found to be in the range of 97.5-99.7% in certified reference material. The results of this study showed that the mean values of cadmium, nickel, and lead were significantly higher in scalp hair samples of both Pakistani and Irish hypertensive patients than in referents (p < 0.001); whereas, the concentration of zinc was lower in the scalp hair samples of hypertensive patients of both genders. The deficiency of zinc and the high exposure of trace and toxic metals may be the risk factors associated with hypertension.

  11. Evaluation of new geological reference materials for uranium-series measurements: Chinese Geological Standard Glasses (CGSG) and macusanite obsidian.

    Science.gov (United States)

    Denton, J S; Murrell, M T; Goldstein, S J; Nunn, A J; Amato, R S; Hinrichs, K A

    2013-10-15

    Recent advances in high-resolution, rapid, in situ microanalytical techniques present numerous opportunities for the analytical community, provided accurately characterized reference materials are available. Here, we present multicollector thermal ionization mass spectrometry (MC-TIMS) and multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) uranium and thorium concentration and isotopic data obtained by isotope dilution for a suite of newly available Chinese Geological Standard Glasses (CGSG) designed for microanalysis. These glasses exhibit a range of compositions including basalt, syenite, andesite, and a soil. Uranium concentrations for these glasses range from ∼2 to 14 μg g(-1), Th/U weight ratios range from ∼4 to 6, (234)U/(238)U activity ratios range from 0.93 to 1.02, and (230)Th/(238)U activity ratios range from 0.98 to 1.12. Uranium and thorium concentration and isotopic data are also presented for a rhyolitic obsidian from Macusani, SE Peru (macusanite). This glass can also be used as a rhyolitic reference material, has a very low Th/U weight ratio (around 0.077), and is approximately in (238)U-(234)U-(230)Th secular equilibrium. The U-Th concentration data agree with but are significantly more precise than those previously measured. U-Th concentration and isotopic data agree within estimated errors for the two measurement techniques, providing validation of the two methods. The large (238)U-(234)U-(230)Th disequilibria for some of the glasses, along with the wide range in their chemical compositions and Th/U ratios should provide useful reference points for the U-series analytical community.

  12. ENERGY STAR Certified Geothermal Heat Pumps

    Science.gov (United States)

    Certified models meet all ENERGY STAR requirements as listed in the Version 3.0 ENERGY STAR Program Requirements for Geothermal Heat Pumps that are effective as of January 1, 2012. A detailed listing of key efficiency criteria are available at http://www.energystar.gov/index.cfm?c=geo_heat.pr_crit_geo_heat_pumps

  13. 28 CFR 33.32 - Certified programs.

    Science.gov (United States)

    2010-07-01

    .... (4) Clearance rates (by arrest) for targeted crimes. (5) Conviction rates for targeted crimes... enable citizens and police to undertake initiatives to prevent and control neighborhood crime. (ii) Certified program: Community crime prevention. This program aims to prevent crime and reduce the fear...

  14. 31 CFR 341.14 - Certifying officers.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Certifying officers. 341.14 Section 341.14 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) FISCAL... imprint of the corporate seal, or, where the institution is an authorized issuing agent for United...

  15. 31 CFR 346.14 - Certifying officers.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Certifying officers. 346.14 Section 346.14 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) FISCAL... imprint of the corporate seal, or, where the institution is an authorized issuing agent for United...

  16. 31 CFR 357.31 - Certifying individuals.

    Science.gov (United States)

    2010-07-01

    ... institutions, corporate central credit unions, and institutions that are members of Treasury-recognized... signed in the certifying individual's presence after he or she has established the identity of the person... prescribed in procedures established by the Department. (4) Officers and employees of corporate...

  17. 31 CFR 306.45 - Certifying individuals.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Certifying individuals. 306.45 Section 306.45 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) FISCAL SERVICE, DEPARTMENT OF THE TREASURY BUREAU OF THE PUBLIC DEBT GENERAL REGULATIONS GOVERNING...

  18. Determination of tungsten in geochemical reference material basalt Columbia River 2 by radiochemical neutron activation analysis and inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, Samuel S.; Beck, Chelsie L.; Bowen, James M.; Eggemeyer, Tere A.; Hines, Corey C.; Liezers, Martin; Metz, Lori A.; Morley, Shannon M.; Restis, Kaitlyn R.; Snow, Mathew; Wall, Donald E.; Clark, Sue B.; Seiner, Brienne N.

    2017-01-02

    Environmental tungsten (W) analyses are inhibited by a lack of reference materials and practical methods to remove isobaric and radiometric interferences. We present a method that evaluates the potential use of commercially available sediment, Basalt Columbia River-2 (BCR-2), as a reference material using neutron activation analysis (NAA) and mass spectrometry. Tungsten concentrations using both methods are in statistical agreement at the 95% confidence interval (92 ± 4 ng/g for NAA and 100 ±7 ng/g for mass spectrometry) with recoveries greater than 95%. These results indicate that BCR-2 may be suitable as a reference material for future studies.

  19. 烟草分析用氯溶液标准物质%Chlorine Solution Reference Material for Tobacco Analysis

    Institute of Scientific and Technical Information of China (English)

    蒋锦锋; 马明; 李栋; 李青常; 范黎

    2011-01-01

    In order to ensure the accuracy and traceability of the test results of chlorine content in tobacco by continuous flow method, the sodium chloride of primary reference material was used as the raw material of solution reference material (SRM). The SRM was prepared via weighing, dissolving, repacking and heat sealing and went through homogeneity and stability test. The mass concentration of the SRM was 0.1001 mg/mL valued by gravimetric method. The main factors influencing the uncertainty of the SRM, including mass, purity, volume, homogeneity and stability, were also analyzed, its uncertainty was of 0.0005 mg/mL.%为了保证连续流动法测定烟草中氯结果的准确性和可溯源性,选择一级标准物质氯化钠为原料,经定量称取和定体积溶解,安瓿瓶分装和热封,研制出氯溶液标准物质.该标准物质经均匀性、稳定性检验,并用重量法定值,其质量浓度为0.1001 mg/mL.对影响该标准物质不确定度的质量、纯度、体积、均匀性、稳定性等因素进行了分析,其不确定度为0.0005 mg/mL.

  20. Multi-product newsvendor problem with hybrid demand and its applications to ordering pharmaceutical reference standard materials

    Science.gov (United States)

    Wang, Dan; Qin, Zhongfeng

    2016-04-01

    Uncertainty is inherent in the newsvendor problem. Most of the existing literature is devoted to characterizing the uncertainty either by randomness or by fuzziness. However, in many cases, randomness and fuzziness simultaneously appear in the same problem. Motivated by this observation, we investigate the multi-product newsvendor problem by considering the demands as hybrid variables which are proposed to describe quantities with double uncertainties. According to the expected value criterion, we formulate an expected profit maximization model and convert it to a deterministic form when the chance distributions are given. We discuss two special cases of hybrid variable demands and give their chance distributions. Then we design hybrid simulation to estimate the chance distribution and use genetic algorithm to solve the proposed models. Finally, we proceed to present numerical examples of purchasing pharmaceutical reference standard materials to illustrate the applicability of our methodology and the effectiveness of genetic algorithm.

  1. Toward standardization of carbohydrate-deficient transferrin (CDT) measurements: II. Performance of a laboratory network running the HPLC candidate reference measurement procedure and evaluation of a candidate reference material.

    Science.gov (United States)

    Helander, Anders; Wielders, Jos P M; Jeppsson, Jan-Olof; Weykamp, Cas; Siebelder, Carla; Anton, Raymond F; Schellenberg, François; Whitfield, John B

    2010-11-01

    Carbohydrate-deficient transferrin (CDT) is a descriptive term used for a temporary change in the transferrin glycosylation profile caused by alcohol, and used as a biomarker of chronic high alcohol consumption. The use of an array of methods for measurement of CDT in various absolute or relative amounts, and sometimes covering different transferrin glycoforms, has complicated the comparability of results and caused confusion among medical staff. This situation prompted initiation of an IFCC Working Group on CDT standardization. This second publication of the WG-CDT covers the establishment of a network of reference laboratories running a high-performance liquid chromatography (HPLC) candidate reference measurement procedure, and evaluation of candidate secondary reference materials. The network laboratories demonstrated good and reproducible performance and thus can be used to assign target values for calibrators and controls. A candidate secondary reference material based on native human serum lyophilized with a cryo-/lyoprotectant to prevent protein denaturation was found to be commutable and stable during storage. A proposed strategy for calibration of different CDT methods is also presented. In an external quality assurance study involving 66 laboratories and covering the current routine CDT assays (HPLC, capillary electrophoresis and immunoassay), recalculation of observed results based on the nominal values for the candidate calibrator reduced the overall coefficient of variation from 18.9% to 5.5%. The logistics for distribution of reference materials and review of results were found to be functional, indicating that a full reference system for CDT may soon be available.

  2. Desenvolvimento de material de referência para microbiologia de alimentos contendo estafilococos coagulase positiva em matriz queijo Development of reference material for the microbiology of foods containing coagulase-positive Staphylococcus in a cheese matrix

    Directory of Open Access Journals (Sweden)

    Marcelo Luiz Lima Brandão

    2013-03-01

    Full Text Available O uso de materiais de referência (MR é uma das principais ferramentas utilizadas para garantia e controle da qualidade de laboratórios de microbiologia de alimentos. No Brasil, a RDC n.º 12/01 da Anvisa prevê como um dos parâmetros para a avaliação da qualidade de queijos a enumeração de estafilococos coagulase positiva (ECP. O grande desafio na produção de MR destinados a ensaios microbiológicos é a instabilidade natural dos micro-organismos, o que dificulta o desenvolvimento e a manutenção desses MR. O objetivo deste estudo foi produzir um MR quantitativo destinado ao ensaio de enumeração de ECP em matriz queijo. Uma amostra de queijo ultrafiltrado com contagem de ECP The use of reference materials (RM is one of the principal tools used for assurance and quality control in food microbiology laboratories. In Brazil, Anvisa RDC nº 12/01 specifies the enumeration of coagulase-positive staphylococcus (CPS as one of the parameters for evaluating cheese quality. The main challenge in the production of RM destined for microbiological assays is the natural instability of the microorganisms, which makes it difficult to develop and maintain them. This study aimed to produce a quantitative RM for use in enumeration assays of CPS in cheese matrixes. A sample of an ultra-filtered cheese with a CPS count of <10 CFU/g and a total nº of viable aerobes of 1.2 × 10³ CFU/g was used as the matrix to produce the RM. The matrix was distributed in flasks, contaminated with specific concentrations of the target bacteria and submitted to freeze-drying. Sucrose was used as the cryo-protector. The RM produced was considered homogeneous and stable at < -70ºC during the entire study period (10 months. The material was shown to be stable at 4, 25, 30 and 35 ºC for 4 days, although the results indicated a decrease in cell concentration at 35 ºC. At -20 ºC the RM was stable for 48 days. It was concluded that the material showed all the necessary

  3. 76 FR 19310 - Information Collection; Certified State Mediation Program

    Science.gov (United States)

    2011-04-07

    ... Farm Service Agency Information Collection; Certified State Mediation Program AGENCY: Farm Service... Mediation Program. The information collection is necessary to ensure the grant program is being administered... following methods: Mail: Carol Wagner, Certified State Mediation Program Manager, USDA, FSA, Appeals...

  4. 7 CFR 205.662 - Noncompliance procedure for certified operations.

    Science.gov (United States)

    2010-01-01

    ... MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) ORGANIC FOODS PRODUCTION ACT PROVISIONS NATIONAL ORGANIC PROGRAM Administrative Compliance § 205.662... of a certified operation by a certifying agent or a State organic program's governing State...

  5. The influence of Saccharomyces cerevisiae enzyme ratio on preparation virgin coconut oil for candidate in-house reference materials

    Science.gov (United States)

    Rohyami, Yuli; Anjani, Rafika Debby; Purwanti, Napthalina Putri

    2017-03-01

    Virgin coconut oil is an excellent product which has result of oil processing business opportunities in the international market. Standardization of virgin coconut oil necessary to satisfy the requirements industry needs. This research is expected as procedure preparation of reference materials. Preparation of virgin coconut oil by Sacharomycescerevisiaeenzyme. Based on the results of this study concluded that the ratio of Saccharomyces cerevisiae can affect the yield of virgin coconut oil produced. The preparation of virgin coconut oil enzymatically using a variety of mass ratio of 0.001 to 0.006% is obtained yield average of 12.40%. The optimum separation of virgin coconut oil on the use of enzymes with a mass ratio of 0.002%. The average water content at a ratio of 0.002% is 0.04 % with a value of uncertainty is 0.005%. The average iodine number in virgin coconut oil produced is 2.4403 ± 0,1974 grams of iodine per 100 grams of oil and optimum iodine number is obtained from the manufacturing process virgin coconut oil with a ratio of 0.006% Saccharomyces cerevisiae. Sacharomycescerevisiae with a ratio of 0.002% results virgin coconut oil with acid number 0.3068 ± 0.1098%. The peroxide value of virgin coconut oil between 0.0108 ± 0.009 to 0.0114 ± 0015milli-equivalent per kilograms. Organoleptic test results and test chemical parameters can be used as the test data that can be developed in prototype preparation of candidate in-house reference material in the testing standards of quality virgin coconut oil.

  6. Synthesis of Precision for the Certification of Phosphorus in Biological Materials by INAA

    DEFF Research Database (Denmark)

    Damsgaard, E.; Heydorn, K.

    1987-01-01

    The β-emitter32P was used to determine total phosphorus by INAA in Skim Milk Powder RM 63, a material now certified by the EEC Bureau of Reference (BCR). Samples and comparator were irradiated in the Danish reactor DR 3. One month later the samples were dissolved in water and aliquots counted...

  7. Establishment of a standard reference material (SRM) herbal DNA barcode library of Vitex negundo L. (lagundi) for quality control measures.

    Science.gov (United States)

    Olivar, Jay Edneil C; Alaba, Joanner Paulus Erik P; Atienza, Jose Francisco M; Tan, Jerick Jeffrey S; Umali, Maximo T; Alejandro, Grecebio Jonathan D

    2016-05-01

    The majority of the population in the Philippines relies on herbal products as their primary source for their healthcare needs. After the recognition of Vitex negundo L. (lagundi) as an important and effective alternative medicine for cough, sore throat, asthma and fever by the Philippine Department of Health (DOH), there was an increase in the production of lagundi-based herbal products in the form of teas, capsules and syrups. The efficiency of these products is greatly reliant on the use of authentic plant material, and to this day no standard protocol has been established to authenticate plant materials. DNA barcoding offers a quick and reliable species authentication tool, but its application to plant material has been less successful due to (1) lack of a standard DNA barcoding loci in plants and (2) poor DNA yield from powderised plant products. This study reports the successful application of DNA barcoding in the authentication of five V. negundo herbal products sold in the Philippines. Also, the first standard reference material (SRM) herbal library for the recognition of authentic V. negundo samples was established using 42 gene accessions of ITS, psbA-trnH and matK barcoding loci. Authentication of the herbal products utilised the SRM following the BLASTn and maximum-likelihood (ML) tree construction criterion. Barcode sequences were retrieved for ITS and psbA-trnH of all products tested and the results of the study revealed that only one out of five herbal products satisfied both BLASTn and ML criterion and was considered to contain authentic V. negundo. The results prompt the urgent need to utilise DNA barcoding in authenticating herbal products available in the Philippine market. Authentication of these products will secure consumer health by preventing the negative effects of adulteration, substitution and contamination.

  8. Marine Reference Materials

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Various publications and other instructions for taking marine weather observations. includes Weather Service Observing Handbook No. 1, Weather Bureau Circular M, and...

  9. Upper Air Reference Materials

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Instructions for observing and recording radiosonde, pilot balloon and other in-situ observations above the earth's surface. Includes Weather Bureau Circular O.

  10. Characterisation of Leather Candidate Certified Reference Materials for their Mass Fractions of Aromatic Amines%用于分析皮革样本中芳香胺含量的检定标准物质的表征(续)

    Institute of Scientific and Technical Information of China (English)

    Jan-Willem Wegener; Haiko Schulz; 龚英

    2011-01-01

    Three batches of leather samples were colored with nine azo dyes that can yield eight proven or suspected carcinogenic aromatic amines under reduction conditions.The samples were milled to grains and bottled in jars.A group of five laboratories has established the mass fraction of the amines in a ring test using different analytical methods.The methods included a reduction step in order to cleave the azo dyes into the aromatic amines.Quantification was by standard addition: sub - samples of the leathers were spiked with known amounts of azo dyes of known purity.It was possible to establish the mass fractions of six of the eight aromatic amines in three of the leather samples.%用9种已经确认或被怀疑的在还原条件下将生成8种致癌芳香胺的染料,对3批皮革样品染色.将皮革样品切碎为颗粒后,装入到广口瓶中.由5个实验室组成的试验组,在环试验中采用不同方法分析这些芳香胺在皮革中所占的质量分数.这些分析方法均包括还原步骤,即,使偶氮染料裂解为芳香胺.采用向皮革子样本加入已知量的且已知纯度的偶氮染料这种标准加入法,进行定量分析.在这3批皮革样品中,可以对这8类芳香胺中的6种进行质量含量的分析.

  11. 30 CFR 71.202 - Certified person; sampling.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Certified person; sampling. 71.202 Section 71... Sampling Procedures § 71.202 Certified person; sampling. (a) The respirable dust sampling required by this... on sampling of respirable coal mine dust. (c) A person may be temporarily certified by MSHA to...

  12. 30 CFR 70.202 - Certified person; sampling.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Certified person; sampling. 70.202 Section 70... HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Sampling Procedures § 70.202 Certified person; sampling. (a) The respirable dust sampling required by this part shall be done by a certified person....

  13. 30 CFR 90.202 - Certified person; sampling.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Certified person; sampling. 90.202 Section 90... Sampling Procedures § 90.202 Certified person; sampling. (a) The respirable dust sampling required by this... on sampling of respirable coal mine dust. (c) A person may be temporarily certified by MSHA to...

  14. 33 CFR 159.17 - Changes to certified devices.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Changes to certified devices. 159... (CONTINUED) POLLUTION MARINE SANITATION DEVICES Certification Procedures § 159.17 Changes to certified devices. (a) The manufacturer of a device that is certified under this part shall notify the...

  15. Chemical Bonding and Structural Information of Black CarbonReference Materials and Individual Carbonaceous AtmosphericAerosols

    Energy Technology Data Exchange (ETDEWEB)

    Hopkins, Rebecca J.; Tivanski, Alexei V.; Marten, Bryan D.; Gilles, Mary K.

    2007-04-25

    The carbon-to-oxygen ratios and graphitic nature of a rangeof black carbon standard reference materials (BC SRMs), high molecularmass humic-like substances (HULIS) and atmospheric particles are examinedusing scanning transmission X-ray microscopy (STXM) coupled with nearedge X-ray absorption fine structure (NEXAFS) spectroscopy. UsingSTXM/NEXAFS, individual particles with diameter>100 nm are studied,thus the diversity of atmospheric particles collected during a variety offield missions is assessed. Applying a semi-quantitative peak fittingmethod to the NEXAFS spectra enables a comparison of BC SRMs and HULIS toparticles originating from anthropogenic combustion and biomass burns,thus allowing determination of the suitability of these materials forrepresenting atmospheric particles. Anthropogenic combustion and biomassburn particles can be distinguished from one another using both chemicalbonding and structural ordering information. While anthropogeniccombustion particles are characterized by a high proportion ofaromatic-C, the presence of benzoquinone and are highly structurallyordered, biomass burn particles exhibit lower structural ordering, asmaller proportion of aromatic-C and contain a much higher proportion ofoxygenated functional groups.

  16. Strategies for building reference standards for autoantibodies

    Directory of Open Access Journals (Sweden)

    Joanna eSheldon

    2015-04-01

    Full Text Available Producing robust, certified, traceable reference material for autoantibody testing is a vital element in maintaining the validity of results that are generated in the daily clinical laboratory routine. This is a huge challenge because of the high number of variables involved in the detection and measurement of the autoantibodies. The production of such materials is time consuming and needs rigorous attention to detail; this is best achieved by an overarching independent body who will oversee the process in a not for profit manner.Much effort has been made to build international standards for quantitative and qualitative assays based on monoclonal antibodies, obtained from affinity purification and plasmapheresis. The big challenge is to respect individual differences in immune response to the same antigen. A promising ongoing initiative is the construction of pools with monospecific samples from different individuals.

  17. Nicotine, acetanilide and urea multi-level2H-,13C- and15N-abundance reference materials for continuous-flow isotope ratio mass spectrometry

    Science.gov (United States)

    Schimmelmann, A.; Albertino, A.; Sauer, P.E.; Qi, H.; Molinie, R.; Mesnard, F.

    2009-01-01

    Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the S values of these reference materials should bracket the isotopic range of samples with unknown S values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW-SLAP) and carbonates (NBS 19 and L-SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA-IRMS). At present only L-glutamic acids USGS40 and USGS41 satisfy these requirements for ??13C and ??13N, with the limitation that L-glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on-line (i.e. continuous flow) hydrogen reductive gas chromatography-isotope ratio mass-spectrometry (GC-IRMS), (ii) five nicotines for oxidative C, N gas chromatography-combustion-isotope ratio mass-spectrometry (GC-C-IRMS, or GC-IRMS), and (iii) also three acetanilide and three urea reference materials for on-line oxidative EA-IRMS for C and N. Isotopic off-line calibration against international stable isotope measurement standards at Indiana University adhered to the 'principle of identical treatment'. The new reference materials cover the following isotopic ranges: ??2Hnicotine -162 to -45%o, ??13Cnicotine -30.05 to +7.72%, ?? 15Nnicotine -6.03 to +33.62%; ??15N acetanilide +1-18 to +40.57%; ??13Curea -34.13 to +11.71%, ??15Nurea +0.26 to +40.61% (recommended ?? values refer to calibration with NBS 19, L-SVEC, IAEA-N-1, and IAEA-N-2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC-IRMS that are available with different ??13N

  18. A preliminary study for the development of reference material using oyster for determination of (137)Cs, (90)Sr and plutonium isotopes.

    Science.gov (United States)

    Lee, Sang-Han; Oh, Jung-Suk; Lee, Jong-Man; Lee, Kyung-Bum; Park, Tae-Soon; Lee, Min-Kie; Kim, Seung-Hwan; Choi, Jong-Ki

    2016-03-01

    A new reference material for the determination of (137)Cs, (90)Sr and Pu isotopes ((238)Pu and (239,240)Pu) is being developed using dried oyster matrix by Korea Research Institute of Standards and Science (KRISS). The oyster was collected from Tongyoung harbour, southern part of Korea and the artificial radionuclides ((137)Cs, (90)Sr, (238)Pu and (239,240)Pu) were spiked into the material. After pretreatment and processing, the material was tested for homogeneity and massic activities were determined by measuring (137)Cs, (90)Sr, (238)Pu and (239,240)Pu. The reference value and extended uncertainty for those isotopes will be reported later.

  19. Middle School Alternatively Certified Science Teachers: Resources, Teacher Choices, and Student Achievement

    Science.gov (United States)

    Linek, Wayne M.; Sampson, Mary Beth; Gomez, Karyn A.; Linder, Patricia E.; Torti, Crystal; Levingston, Ceretha; Palmer, Joel

    2009-01-01

    In the present study, alternatively certified 5th-grade teachers used textbooks and worksheets as primary teaching materials because of their limited access to trade books. The limited number of trade books that these teachers used were mostly scientifically accurate. However, a large proportion of the trade books integrated into the science…

  20. Governing "Eco-Certified Children" through Pastoral Power: Critical Perspectives on Education for Sustainable Development

    Science.gov (United States)

    Ideland, Malin; Malmberg, Claes

    2015-01-01

    This article analyses how "eco-certified children" are constructed as desirable subjects in teaching materials addressing education for sustainable development. We are interested in how discourses structure this cherished practice and how this practice has become "natural" and obvious for us. A discourse analysis is carried out…

  1. Hair analysis for drugs of abuse: evaluation of analytical methods, environmental issues, and development of reference materials.

    Science.gov (United States)

    Welch, M J; Sniegoski, L T; Allgood, C C; Habram, M

    1993-01-01

    Methods for extraction of cocaine, some of its metabolites, morphine, and codeine from hair and methods for analyzing the extracts have been investigated. Results of these studies have shown that extractions with 0.1N HCl are efficient at removing the target compounds from hair and appear to be as effective as enzymatic digestions that dissolve the hair. GC/MS with either electron ionization or chemical ionization was found to provide accurate and unambiguous determinations of the target compounds. Tandem mass spectrometry (MS/MS) also provided accurate results when performed on extracts from hair, but results were ambiguous when MS/MS was performed on hair segments directly. Environmental issues, including the removal of powdered and vapor-deposited cocaine from the hair surface and the effect of various hair treatments on the levels of cocaine entrapped in hair, have also been investigated. Removal of cocaine deposited on hair was incomplete by all approaches tested, making differentiation of hair of cocaine users from hair with environmental exposure of cocaine difficult. Cocaethylene, a cocaine metabolite believed to be formed in the liver, was found in the hair of some cocaine users and may be a good marker for proving drug use. Common hair treatments, such as shampoos, conditioners, and peroxide bleaches, reduced cocaine levels in a fortified hair material by 60 to 80% after 30 treatments. Finally, to assist laboratories in evaluating the accuracy of their methods, two human hair reference materials with recommended concentrations of cocaine, benzoylecgonine, morphine, and codeine determined by GC/MS have been developed.

  2. Determination of caffeine, theobromine, and theophylline in standard reference material 2384, baking chocolate, using reversed-phase liquid chromatography.

    Science.gov (United States)

    Thomas, Jeanice Brown; Yen, James H; Schantz, Michele M; Porter, Barbara J; Sharpless, Katherine E

    2004-06-02

    A rapid and selective isocratic reversed-phase liquid chromatographic method has been developed at the National Institute of Standards and Technology to simultaneously measure caffeine, theobromine, and theophylline in a food-matrix standard reference material (SRM) 2384, Baking Chocolate. The method uses isocratic elution with a mobile phase composition (volume fractions) of 10% acetronitrile/90% water (pH adjusted to 2.5 using acetic acid) at a flow rate of 1.5 mL/min with ultraviolet absorbance detection (274 nm). Total elution time for these analytes is less than 15 min. Concentration levels of caffeine, theobromine, and theophylline were measured in single 1-g samples taken from each of eight bars of chocolate over an eight-day period. Samples were defatted with hexane, and beta-hydroxyethyltheophylline was added as the internal standard. The repeatability for the caffeine, theobromine, and theophylline measurements was 5.1, 2.3, and 1.9%, respectively. The limit of quantitation for all analytes was theobromine, and theophylline in SRM 2384.

  3. Reference intervals for thyreotropin and thyroid hormones for healthy adults based on the NOBIDA material and determined using a Modular E170

    DEFF Research Database (Denmark)

    Friis-Hansen, Lennart; Hilsted, Linda

    2008-01-01

    BACKGROUND: The aim of the present study was to establish Nordic reference intervals for thyreotropin (TSH) and the thyroid hormones in heparinized plasma. METHODS: We used 489 heparinized blood samples, collected in the morning, from the Nordic NOBIDA reference material, from healthy adults...... by removal of the TPO-ab and TG-ab positive samples. CONCLUSIONS: The upper limit of the TSH reference interval in our study is high compared to some other recent reports. This could be due to blood sampling in the morning. Furthermore, the Roche platform gives slightly higher results than other platforms....... The number and distribution of the samples in the NOBIDA material makes it suitable for the determination of hormone Nordic reference intervals....

  4. Going the distance for certified cancer registrars.

    Science.gov (United States)

    Backus, Amanda; Kolender, Ellen R

    2009-01-01

    Cancer registry departments are using electronic technology to solve the local and national Certified Tumor Registrar (CTR) shortages. As demand for CTRs continues to increase without an accompanied increase in the supply of qualified personnel, cancer registry departments are looking for new solutions to this growing local and national trend. In order to solve this problem, some cancer registries have started using telecommunication to fill the empty positions within their departments. This is the case at Roper St. Francis Healthcare (RSFH) in Charleston, SC, where Cancer Registry Manager, Ellen Kolender, RHIA, CTR, used telecommuting to fill one full-time and one part-time CTR position.

  5. CISA Certified Information Systems Auditor : study guide

    CERN Document Server

    Cannon, David L

    2011-01-01

    The industry-leading study guide for the CISA exam, fully updated. More than 27,000 IT professionals take the Certified Information Systems Auditor exam each year. SC Magazine lists the CISA as the top certification for security professionals. Compliances, regulations, and best practices for IS auditing are updated twice a year, and this is the most up-to-date book available to prepare aspiring CISAs for the next exam.: CISAs are among the five highest-paid IT security professionals; more than 27,000 take the exam each year and the numbers are growing; Standards are updated twice a year, and t

  6. Best Reference Sources 2001.

    Science.gov (United States)

    Coutts, Brian; McConnell, Tamara

    2002-01-01

    Presents an annotated list of the best reference materials published in 2001. Discusses activity in the reference publishing industry; costs; and lists print materials, Web sites, databases, and CD-ROMs. (LRW)

  7. Training and Certification Program for Certified Energy Auditors (CEA) and Certified Building Commissioning Professionals (CBCP)

    Energy Technology Data Exchange (ETDEWEB)

    Kent, Bill

    2012-08-24

    The Association of Energy Engineers (AEE) has offered energy efficiency training and certification programs for over 30 years. During that time AEE has certified more than 22,000 professionals. All of our certification programs are the result of extensive industry research and program development and oversight by certification boards. For this project award, AEE proposed to work with the Department of Energy to utilize and extend existing industry recognized Certified Energy Auditor (CEA) and Certified Building Commissioning Professional (CBCP) programs under this Training Program Development Announcement. These expanded training programs will have significant impact in training professionals for building commissioning and energy auditing to achieve the goal of bringing existing buildings up to their optimal energy performance potential and ensuring that new buildings maintain their expected optimal level of performance. The goals and objectives of the training development project were achieved with the development of new training programs that are now being offered as self-sustaining commercial training and certification programs. These new programs are training and certifying professionals who are accomplishing the goal of increasing building energy performance in both existing and new buildings.

  8. 77 FR 5415 - National Organic Program: Notice of Draft Guidance for Accredited Certifying Agents, Certified...

    Science.gov (United States)

    2012-02-03

    ...; ] DEPARTMENT OF AGRICULTURE Agricultural Marketing Service 7 CFR Part 205 National Organic Program: Notice of... Certified Organic Products AGENCY: Agricultural Marketing Service, USDA. ACTION: Notice of availability with..., Agricultural Marketing Specialist, National Organic Program, USDA-AMS- NOP, 1400 Independence Ave. SW.,...

  9. Random numbers certified by Bell's theorem.

    Science.gov (United States)

    Pironio, S; Acín, A; Massar, S; de la Giroday, A Boyer; Matsukevich, D N; Maunz, P; Olmschenk, S; Hayes, D; Luo, L; Manning, T A; Monroe, C

    2010-04-15

    Randomness is a fundamental feature of nature and a valuable resource for applications ranging from cryptography and gambling to numerical simulation of physical and biological systems. Random numbers, however, are difficult to characterize mathematically, and their generation must rely on an unpredictable physical process. Inaccuracies in the theoretical modelling of such processes or failures of the devices, possibly due to adversarial attacks, limit the reliability of random number generators in ways that are difficult to control and detect. Here, inspired by earlier work on non-locality-based and device-independent quantum information processing, we show that the non-local correlations of entangled quantum particles can be used to certify the presence of genuine randomness. It is thereby possible to design a cryptographically secure random number generator that does not require any assumption about the internal working of the device. Such a strong form of randomness generation is impossible classically and possible in quantum systems only if certified by a Bell inequality violation. We carry out a proof-of-concept demonstration of this proposal in a system of two entangled atoms separated by approximately one metre. The observed Bell inequality violation, featuring near perfect detection efficiency, guarantees that 42 new random numbers are generated with 99 per cent confidence. Our results lay the groundwork for future device-independent quantum information experiments and for addressing fundamental issues raised by the intrinsic randomness of quantum theory.

  10. Desenvolvimento de material de referência para microbiologia de alimentos contendo Listeria monocytogenes em matriz queijo

    Directory of Open Access Journals (Sweden)

    Marcelo Luiz Lima Brandão

    2013-10-01

    Full Text Available A NBR ISO/IEC 17025:2005, uma das normas mais utilizadas em laboratórios de ensaio, descreve como um de seus critérios para a garantia da qualidade dos resultados analíticos a participação periódica dos laboratórios em ensaios de proficiência (EP. Os analitos, utilizados nos EP são materiais de referência (MR provenientes de um mesmo lote, e devem apresentar características de homogeneidade e estabilidade. O objetivo deste estudo foi produzir um MR qualitativo destinado ao ensaio de pesquisa de Listeria monocytogenes em matriz queijo pela técnica de liofilização. Para a produção do MR, foi utilizado como matriz o queijo Minas frescal (QMF ultrafiltrado. A matriz foi distribuída em frascos, contaminada com a bactéria alvo e submetida à liofilização, tendo a sacarose como crioprotetor. O MR produzido foi considerado homogêneo e estável na temperatura de ≤-70°C durante todo o período estudado (10 meses. O material apresentou estabilidade a 4, 25, 30 e 35°C por quatro dias e a -20°C por 48 dias, e os resultados estatísticos indicam tendência à estabilidade. Conclui-se que o material apresentou todos os requisitos necessários de um MR de qualidade e poderia ser transportado aos laboratórios participantes de um EP à temperatura máxima de 35°C por até quatro dias, uma vez que os resultados indicaram a manutenção da concentração celular nesse período. Esse foi o primeiro trabalho a descrever uma metodologia de produção de MR contendo L. monocytogenes em matriz queijo.

  11. Isolation and characterization of gluten protein types from wheat, rye, barley and oats for use as reference materials

    Science.gov (United States)

    Schalk, Kathrin; Lexhaller, Barbara; Koehler, Peter

    2017-01-01

    Gluten proteins from wheat, rye, barley and, in rare cases, oats, are responsible for triggering hypersensitivity reactions such as celiac disease, non-celiac gluten sensitivity and wheat allergy. Well-defined reference materials (RM) are essential for clinical studies, diagnostics, elucidation of disease mechanisms and food analyses to ensure the safety of gluten-free foods. Various RM are currently used, but a thorough characterization of the gluten source, content and composition is often missing. However, this characterization is essential due to the complexity and heterogeneity of gluten to avoid ambiguous results caused by differences in the RM used. A comprehensive strategy to isolate gluten protein fractions and gluten protein types (GPT) from wheat, rye, barley and oat flours was developed to obtain well-defined RM for clinical assays and gluten-free compliance testing. All isolated GPT (ω5-gliadins, ω1,2-gliadins, α-gliadins, γ-gliadins and high- and low-molecular-weight glutenin subunits from wheat, ω-secalins, γ-75k-secalins, γ-40k-secalins and high-molecular-weight secalins from rye, C-hordeins, γ-hordeins, B-hordeins and D-hordeins from barley and avenins from oats) were fully characterized using analytical reversed-phase high-performance liquid chromatography (RP-HPLC), sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE), N-terminal sequencing, electrospray-ionization quadrupole time-of-flight mass spectrometry (LC-ESI-QTOF-MS) and untargeted LC-MS/MS of chymotryptic hydrolyzates of the single GPT. Taken together, the analytical methods confirmed that all GPT were reproducibly isolated in high purity from the flours and were suitable to be used as RM, e.g., for calibration of LC-MS/MS methods or enzyme-linked immunosorbent assays (ELISAs). PMID:28234993

  12. Organic Reference Materials for Hydrogen, Carbon, and Nitrogen Stable Isotope-Ratio Measurements : Caffeines, n-Alkanes, Fatty Acid Methyl Esters, Glycines, L-Valines, Polyethylenes, and Oils

    NARCIS (Netherlands)

    Schimmelrnann, Arndt; Qi, Haiping; Coplen, Tyler B.; Brand, Willi A.; Fong, Jon; Meier-Augenstein, Wolfram; Kemp, Helen F.; Toman, Blaza; Ackermann, Annika; Assonov, Sergey; Aerts-Bijma, Anita T.; Brejcha, Ramona; Chikaraishi, Yoshito; Darwish, Tamim; Elsner, Martin; Gehre, Matthias; Geilmann, Heike; Groeing, Manfred; Helie, Jean-Francois; Herrero-Martin, Sara; Meijer, Harro A. J.; Sauer, Peter E.; Sessions, Alex L.; Werner, Roland A.

    2016-01-01

    An international project developed, quality-tested, and determined isotope-delta values of 19 new organic reference materials (RMs) for hydrogen, carbon, and nitrogen stable isotope-ratio measurements, in addition to analyzing pre-existing RMs NBS 22 (oil), IAEA-CH-7 (polyethylene foil), and IAEA-60

  13. Studies of critical factors in the determination of arsenic in standard reference materials of marine origin by ETAAS:NMKL interlaboratory study

    DEFF Research Database (Denmark)

    Julshamn, K.; Maage, A.; Larsen, Erik Huusfeldt

    1996-01-01

    A study to determine factors which are known to influence the electrothermal atomic absorption (ETAAS) determination of As has been performed. The study has been carried out using five sample solutions of marine Standard Reference Materials distributed to four participating laboratories. Uncoated...

  14. Comprehensive analysis for major, minor and trace element contents and Sr-Nd-Pb-Hf isotope ratios in sediment reference materials, JSd-1 and MAG-1

    Digital Repository Service at National Institute of Oceanography (India)

    Nath, B.N.; Makishima, A.; Noordmann, J.; Tanaka, R.; Nakamura, E.

    In view of the requirement of a well-characterized and easily available aquatic sediment reference material, a comprehensive analysis comprising of fifty major, minor and trace elements as well as Sr–Nd–Pb–Hf isotopes were carried out...

  15. Comprehensive inter-laboratory calibration of reference materials for delta O-18 versus VSMOW using various on-line high-temperature conversion techniques

    NARCIS (Netherlands)

    Brand, Willi A.; Coplen, Tyler B.; Aerts-Bijma, Anita T.; Böhlke, J.K.; Gehre, Matthias; Geilmann, Heike; Gröning, Manfred; Jansen, Henk G.; Meijer, Harro A. J.; Mroczkowski, Stanley J.; Qi, Haiping; Soergel, Karin; Stuart-Williams, Hilary; Weise, Stephan M.; Werner, Roland A.

    2009-01-01

    Internationally distributed organic and inorganic oxygen isotopic reference materials have been calibrated by six laboratories carrying out more than 5300 measurements using a variety of high-temperature conversion techniques (HTC)a in an evaluation sponsored by the International Union of Pure and A

  16. Random Numbers Certified by Bell's Theorem

    CERN Document Server

    Pironio, S; Massar, S; de la Giroday, A Boyer; Matsukevich, D N; Maunz, P; Olmschenk, S; Hayes, D; Luo, L; Manning, T A; Monroe, C

    2009-01-01

    Randomness is difficult to characterize mathematically, and its generation must rely on an unpredictable physical process. Inaccuracies in the theoretical modelling of such processes or failures of the devices, possibly due to adversarial attacks, limit the reliability of random number generators in ways that are difficult to control and detect. Here, we show that the nonlocal correlations of entangled quantum particles can be used to design a new type of cryptographically secure random number generator without the need for any assumptions on the internal working of the devices. This strong form of randomness generation is impossible classically and possible in quantum systems only if certified by a Bell inequality violation. We demonstrate this proposal in a system of two entangled atoms separated by approximately 1 meter. The observed Bell inequality violation, featuring near-perfect detection efficiency, guarantees that 42 new random numbers are generated with 99% confidence. Our results lay the groundwork...

  17. Preparation of Reference Material of Moisture in Methanol%甲醇中微量水分标准物质的研制

    Institute of Scientific and Technical Information of China (English)

    王乐新; 许思思; 王云; 李锋丽; 黄清波; 郭波

    2015-01-01

    The reference material of moisture in methanol was prepared by using anhydrous ethanol. The uniformity and stability were tested. The testing results showed that the reference material exhibited good uniformity and stability, the value showed no significant changes in one year. The standard value was defined by the way of comparison with the national primary reference material. The standard value of reference material of moisture in methanol was 0.103%, Urel=3%(k=2). The reference material can meet the requirement of verification and calibration of Carle Fischer moisture titrators.%用无水甲醇试剂研制了甲醇中微量水分标准物质,对研制的标准物质量值进行了均匀性和稳定性检验。结果表明,该标准物质均匀性良好,其量值在一年内无显著变化,具有较好的稳定性。采用与国家一级标准物质比较法进行定值,研制的甲醇中微量水分标准物质的定值结果为0.103%,相对扩展不确定度为3%(k=2)。该标准物质满足卡尔·费休水分测定仪检定校准的要求。

  18. New Robust Reference Materials for In Situ Single Grain Rutile U-Pb Geochronology and Method Refinements for Detrital Rutile Analysis by LA-MC-ICP-MS

    Science.gov (United States)

    Parrish, R. R.; Bracciali, L.; Condon, D. J.; Horstwood, M. S.; Najman, Y.

    2012-12-01

    While rutile (TiO2) occurs in the heavy mineral suite of detrital sediments and originates mainly in medium- to high-grade metamorphic and some igneous rocks, there are very few applications of U-Pb dating of rutile to provenance studies; this is due to an overreliance on zircon, low U content of rutile limiting measurement quality by in situ methods, a higher proportion of common Pb relative to zircon, and a lack of widely available good quality reference materials. We have addressed these issues and characterized two ~ 1.8 Ga rutile reference materials by SEM, trace elements, U-Pb ID-TIMS, and intra-grain and inter-grain U-Pb LA-MC-ICP-MS analysis using mixed faraday and multiple ion counting detectors with high sensitivity. We have assessed U-Pb discordance and in situ variations in relative common Pb and age and their bearing on the quality of the reference materials for in situ U-Pb dating. The rutiles (Sugluk-4 and PCA-S207) come from granulite facies belts of the Canadian Shield, namely the northern Cape Smith Belt of Quebec and the Snowbird Tectonic Zone (Sasatchewan). The ID-TIMS data are slightly discordant due to variable common Pb and limited Pb loss; the variation in 6 single grains of Sugluk-4, that we use as the primary reference material, is 75% of all rutile grains in a sediment; unsuccessful analyses are due to poor quality rutiles with massive common Pb and/or U contents Horstwood M.S.A., Najman,Y., Two new rutile reference materials for in situ U-Pb LA-MC-ICP-MS dating and applications to sedimentary provenance, submitted to Chem. Geol.

  19. Determination of the absolute 32S/34S ratio of IAEA-S-1 reference material and V-CDT sulfur isotope standard

    Institute of Scientific and Technical Information of China (English)

    丁悌平; 白瑞梅; 李延河; 万德芳; 邹晓秋; 张青莲

    1999-01-01

    The absolute 32S/34S ratios of IAEA-S-1 reference material and V-CDT standard are determined. For cross-checking, two sets of synthetic isotope mixtures are prepared from high purity 32S and 34S-enriched materials in different forms: the first set is prepared from BaSO4 whereas the second is prepared from Ag2S. The sulfur isotope analyses are done by using SF6 method with a MAT-251 EM mass spectrometer. The resulting 32S/34S ratio of IAEAS-1 reference material is 22.656 4±0. 006 0, and that of V-CDT is 22. 649 6±0. 006 0.

  20. Determination of nickel in biological materials after microwave dissolution using inductively coupled plasma atomic emission spectrometry with prior extraction into butan-1-ol.

    Science.gov (United States)

    Vereda Alonso, E; García de Torres, A; Cano Pavón, J M

    1992-07-01

    A sensitive procedure has been developed for the determination of ultratrace amounts of nickel in biological materials by inductively coupled plasma atomic emission spectrometry after extraction of the nickel ion into butan-1-ol by using 1,5-bis(di-2-pyridylmethylene)thiocarbonohydrazide as the extracting reagent. Fast, efficient and complete sample digestion is achieved by an HNO3-HCl poly(tetrafluoroethylene) bomb dissolution technique using microwave heating. Results obtained for eleven certified reference materials agreed with the certified values.

  1. 47 CFR 15.202 - Certified operating frequency range.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Certified operating frequency range. 15.202 Section 15.202 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Intentional Radiators § 15.202 Certified operating frequency range. Client devices that operate in a...

  2. 19 CFR 159.36 - Multiple certified rates.

    Science.gov (United States)

    2010-04-01

    ... TREASURY (CONTINUED) LIQUIDATION OF DUTIES Conversion of Foreign Currency § 159.36 Multiple certified rates... rates of exchange (e.g., official and free) for a foreign currency: (a) Rates to be published. When the... multiple rates have been certified for a foreign currency, the rate to be used for Customs purposes...

  3. 19 CFR 159.35 - Certified daily rate.

    Science.gov (United States)

    2010-04-01

    ... TREASURY (CONTINUED) LIQUIDATION OF DUTIES Conversion of Foreign Currency § 159.35 Certified daily rate. The daily buying rate of foreign currency which is determined by the Federal Reserve Bank of New York... the conversion of foreign currency whenever a proclaimed rate or certified quarterly rate is...

  4. 19 CFR 159.34 - Certified quarterly rate.

    Science.gov (United States)

    2010-04-01

    ... TREASURY (CONTINUED) LIQUIDATION OF DUTIES Conversion of Foreign Currency § 159.34 Certified quarterly rate. (a) Countries for which quarterly rate is certified. For the currency of each of the following... York for such foreign currency for a day in that quarter: Australia, Austria, Belgium, Brazil,...

  5. 7 CFR 97.143 - Certified seed only.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Certified seed only. 97.143 Section 97.143 Agriculture... PLANT VARIETY AND PROTECTION Marking Or Labeling Provisions § 97.143 Certified seed only. (a) Upon filing an application, or amendment thereto, specifying seed of the variety is to be sold by variety...

  6. 36 CFR 61.7 - Subgrants to certified local governments.

    Science.gov (United States)

    2010-07-01

    ... INTERIOR PROCEDURES FOR STATE, TRIBAL, AND LOCAL GOVERNMENT HISTORIC PRESERVATION PROGRAMS § 61.7 Subgrants to certified local governments. (a) Each SHPO must transfer at least 10 percent of its annual... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Subgrants to certified...

  7. 36 CFR 61.6 - Certified local government programs.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Certified local government... INTERIOR PROCEDURES FOR STATE, TRIBAL, AND LOCAL GOVERNMENT HISTORIC PRESERVATION PROGRAMS § 61.6 Certified local government programs. (a) Each approved State program must provide a mechanism for...

  8. Extract-filter-shoot liquid chromatography with mass spectrometry for the analysis of vitamin D2 in a powdered supplement capsule and standard reference material 3280.

    Science.gov (United States)

    Byrdwell, William Craig

    2014-08-01

    An "extract-filter-shoot" method for the analysis of vitamin D2, ergocalciferol, in a dry powdered dietary supplement capsule containing rice flour excipient and in a National Institute of Standards and Technology standard reference material 3280 is reported. Quantification of vitamin D2 was done by atmospheric pressure chemical ionization mass spectrometry using selected ion monitoring, two transitions of selected reaction monitoring, and extracted ion chromatograms from full scans. UV detection was used for the quantification of Vitamin D2 in the dry powder capsule, whereas interfering species rendered UV detection unreliable for standard reference material 3280. Average values for standard reference material 3280 ranged from 8.27 ± 0.58 to 8.33 ± 0.57 μg/g using internal standard calibration and response factor approaches, compared to the previous National Institute of Standards and Technology internal value for vitamin D2 of 8.78 ± 0.11 μg/g, and the recently updated reference value of 8.6 ± 2.6 μg/g. The powdered supplement capsule was found to contain 28.19 ± 0.35 to 28.67 ± 0.90 μg/capsule for a capsule labeled to contain 25.00 μg. The triacylglycerol composition of the rice flour excipient in the powdered supplement capsule determined by atmospheric pressure chemical ionization mass spectrometry is also reported.

  9. Preparation of waterproof OSL dosimeters from hygroscopic materials with a special reference to NaCl:Cu

    Science.gov (United States)

    More, Y. K.; Wankhede, S. P.; Patil, R. R.; Kulkarni, M. S.; Kumar, Munish; Moharil, S. V.

    2016-05-01

    Optically stimulated luminescence (OSL) originally developed for geological/archaeological dating, has been found very useful for diverse applications in the field of radiation dosimetry. There is still a scarcity of OSL materials with demonstrated properties suited to dosimetry applications. Progress on the development of OSL materials with engineered properties has been slow and most research has focused on the OSL characterization of existing materials. One of the reasons for availability of only a handful of OSL dosimetry materials with adequate properties is that they have to satisfy certain stringent conditions necessary for such applications. Especially, hygroscopic materials are considered totally unsuitable. The efforts were made in our laboratory to overcome this problem. It is shown here that "water-proof" dosimeters can be prepared from even hygroscopic materials such as NaCl.

  10. USGS46 Greenland ice core water – A new isotopic reference material for δ2H and δ18O measurements of water

    Science.gov (United States)

    Coplen, Tyler B.; Qi, Haiping; Tarbox, Lauren V.; Lorenz, Jennifer M.; Buck, Bryan

    2015-01-01

    Ice core from Greenland was melted, filtered, homogenised, loaded into glass ampoules, sealed, autoclaved to eliminate biological activity, and calibrated by dual-inlet isotope-ratio mass spectrometry. This isotopic reference material (RM), USGS46, is intended as one of two secondary isotopic reference waters for daily normalisation of stable hydrogen (δ2H) and stable oxygen (δ18O) isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. The measured δ2H and δ18O values of this reference water were −235.8 ± 0.7‰ and −29.80 ± 0.03‰, respectively, relative to VSMOW on scales normalised such that the δ2H and δ18O values of SLAP reference water are, respectively, −428 and −55.5‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95-percent probability of encompassing the true value. This reference water is available in cases containing 144 glass ampoules that are filled with either 4 ml or 5 ml of water per ampoule.

  11. Controlul materialelor forestiere de reproducere: trasabilitatea genetică, contribuţie la gestionarea durabilă a pădurilor [The control of the forest reproductive material: the genetic traceability, support for forest certifi cation and a sustainable forest management

    Directory of Open Access Journals (Sweden)

    Teodosiu Maria

    2014-12-01

    Full Text Available For a sustainable forest management, beside the choice of the right species in artificial regeneration, the right provenances present their own importance. The existing legal regulation on forest reproductive material moving in trade can only provide an absolute proof of identity, at an unproportionally intense level of controlling. Techniques based on the analysis of DNA markers are a powerful tool for the genetic traceability of forest reproductive material, but on a European level, the traceability systems are yet missing, excepting the two certification systems implemented in Germany (ZüF and FfV. The reference samples collected from individuals in different steps of the forest reproductive material production, and the comparison of their genetic composition, are the principle underlying the German certification systems. The seeds from seed orchards can be identified with highly polymorphic SSR markers, once the the genetic profile of the reference clone is known, without reference samples. For different pourpose, suitable DNA markers are available, and the nuclear microsatellies are the more usefull in individual identification. Different statistical approaches can still be used to assign individual or groups of individuals to a population, but this requires further evaluation for their use in traceability. The control procedures are under development at European level. Their implementation are necessary also in Romania, as connecting to the present scientifical trends, and also related to its position as seeds provided for other European countries.

  12. What is in a label? Rainforest-Alliance certified banana production versus non-certified conventional banana production

    Directory of Open Access Journals (Sweden)

    Angelina Sanderson Bellamy

    2016-07-01

    Full Text Available Export banana production in Latin America is pesticide intensive, receiving much negative publicity regarding human health problems and environmental degradation. The Rainforest Alliance (RA certification scheme was established to certify farms that met a number of social, occupation health and environmental standards set by RA and their certifying body, the Sustainable Agriculture Network (SAN. This study was one of the first, independent studies of the environmental impact of some of the principles set by RA and SAN. The study focuses on insect and bird diversity as an indicator of ecosystem health. Five RA certified farms, six non-RA certified farms, and five organic certified farms were sampled. The data was analyzed with RDA multivariate analyses and Monte Carlo permutation tests. The results showed that RA certified farms had less insect diversity compared to non-RA certified farms and that both farm types had less insect diversity than organic farms. There was little difference between RA and non-RA certified farms with regards bird community composition. Thus, organic farming conserves biodiversity, while alternative environmental labels (e.g. a Rainforest alliance seal may not have any visible positive effect on in-farm biodiversity. This study points to the need for improvements in SAN certification standards to achieve improved environmental conditions.

  13. Estudo da utilização de materiais de referência nas análises de água por laboratórios envolvidos no sistema de acreditação Case study on the usage of reference materials in water analysis by laboratories involved in the accreditation system

    Directory of Open Access Journals (Sweden)

    Suzana Saboia de Moura

    2009-01-01

    Full Text Available O presente estudo propõe-se discutir o uso de materiais de referência (MR pelos laboratórios de ensaios de águas, sob o ponto de vista da aquisição dos materiais conforme o item "Aquisição de serviços e suprimentos" (4.6 da norma ABNT NBR ISO/IEC 17025. O papel dos MR nas análises químicas é fornecer referências metrológicas visando assegurar a rastreabilidade das medições. A rastreabilidade é um aspecto essencial da garantia da qualidade para se obter aceitação de dados analíticos nos mercados nacional e internacional. Neste estudo de caso, de caráter exploratório e qualitativo, uma pesquisa foi realizada junto a todos os laboratórios de ensaios prestadores de serviços analíticos para a Agência Nacional de Águas (ANA e envolvidos no sistema de acreditação pela Coordenação Geral de Acreditação do Inmetro (Cgcre/Inmetro, utilizando-se questionário estruturado e com 50% de retorno. Os resultados mostraram que são muito poucos os certificados de MR com reconhecimento de terceira parte, ou seja, por organismos de acreditação, segundo normas consagradas que tratam efetivamente da rastreabilidade metrológica. Propõe-se, finalmente, uma política para garantir, sempre que possível, a rastreabilidade dos resultados de ensaios dos laboratórios, na ausência de MR certificados.This paper aims at discussing the use of reference materials (RM by water testing laboratories, on the context of RM purchase, based on the requirements of the standard ABNT NBR ISO/IEC 17025, section "Purchasing services and supplies" (4.6. The role of RM in chemical analysis is to provide metrological reference to assure measurement traceability. This is an essential aspect of quality assurance in order to have analytical results accepted in the international market. In this case study, based on the methodological exploratory and qualitative approach, a questionnaire was sent to testing laboratories which provide analytical services to the

  14. USGS42 and USGS43: Human-hair stable hydrogen and oxygen isotopic reference materials and analytical methods for forensic science and implications for published measurement results

    Science.gov (United States)

    Coplen, T.B.; Qi, H.

    2012-01-01

    Because there are no internationally distributed stable hydrogen and oxygen isotopic reference materials of human hair, the U.S. Geological Survey (USGS) has prepared two such materials, USGS42 and USGS43. These reference materials span values commonly encountered in human hair stable isotope analysis and are isotopically homogeneous at sample sizes larger than 0.2 mg. USGS42 and USGS43 human-hair isotopic reference materials are intended for calibration of δ(2)H and δ(18)O measurements of unknown human hair by quantifying (1) drift with time, (2) mass-dependent isotopic fractionation, and (3) isotope-ratio-scale contraction. While they are intended for measurements of the stable isotopes of hydrogen and oxygen, they also are suitable for measurements of the stable isotopes of carbon, nitrogen, and sulfur in human and mammalian hair. Preliminary isotopic compositions of the non-exchangeable fractions of these materials are USGS42(Tibetan hair)δ(2)H(VSMOW-SLAP) = -78.5 ± 2.3‰ (n = 62) and δ(18)O(VSMOW-SLAP) = +8.56 ± 0.10‰ (n = 18) USGS42(Indian hair)δ(2)H(VSMOW-SLAP) = -50.3 ± 2.8‰ (n = 64) and δ(18)O(VSMOW-SLAP) = +14.11 ± 0.10‰ (n = 18). Using recommended analytical protocols presented herein for δ(2)H(VSMOW-SLAP) and δ(18)O(VSMOW-SLAP) measurements, the least squares fit regression of 11 human hair reference materials is δ(2)H(VSMOW-SLAP) = 6.085δ(2)O(VSMOW-SLAP) - 136.0‰ with an R-square value of 0.95. The δ(2)H difference between the calibrated results of human hair in this investigation and a commonly accepted human-hair relationship is a remarkable 34‰. It is critical that readers pay attention to the δ(2)H(VSMOW-SLAP) and δ(18)O(VSMOW-SLAP) of isotopic reference materials in publications, and they need to adjust the δ(2)H(VSMOW-SLAP) and δ(18)O(VSMOW-SLAP) measurement results of human hair in previous publications, as needed, to ensure all results on are on the same scales.

  15. USGS42 and USGS43: human-hair stable hydrogen and oxygen isotopic reference materials and analytical methods for forensic science and implications for published measurement results.

    Science.gov (United States)

    Coplen, Tyler B; Qi, Haiping

    2012-01-10

    Because there are no internationally distributed stable hydrogen and oxygen isotopic reference materials of human hair, the U.S. Geological Survey (USGS) has prepared two such materials, USGS42 and USGS43. These reference materials span values commonly encountered in human hair stable isotope analysis and are isotopically homogeneous at sample sizes larger than 0.2 mg. USGS42 and USGS43 human-hair isotopic reference materials are intended for calibration of δ(2)H and δ(18)O measurements of unknown human hair by quantifying (1) drift with time, (2) mass-dependent isotopic fractionation, and (3) isotope-ratio-scale contraction. While they are intended for measurements of the stable isotopes of hydrogen and oxygen, they also are suitable for measurements of the stable isotopes of carbon, nitrogen, and sulfur in human and mammalian hair. Preliminary isotopic compositions of the non-exchangeable fractions of these materials are USGS42(Tibetan hair)δ(2)H(VSMOW-SLAP) = -78.5 ± 2.3‰ (n = 62) and δ(18)O(VSMOW-SLAP) = +8.56 ± 0.10‰ (n = 18) USGS42(Indian hair)δ(2)H(VSMOW-SLAP) = -50.3 ± 2.8‰ (n = 64) and δ(18)O(VSMOW-SLAP) = +14.11 ± 0.10‰ (n = 18). Using recommended analytical protocols presented herein for δ(2)H(VSMOW-SLAP) and δ(18)O(VSMOW-SLAP) measurements, the least squares fit regression of 11 human hair reference materials is δ(2)H(VSMOW-SLAP) = 6.085δ(2)O(VSMOW-SLAP) - 136.0‰ with an R-square value of 0.95. The δ(2)H difference between the calibrated results of human hair in this investigation and a commonly accepted human-hair relationship is a remarkable 34‰. It is critical that readers pay attention to the δ(2)H(VSMOW-SLAP) and δ(18)O(VSMOW-SLAP) of isotopic reference materials in publications, and they need to adjust the δ(2)H(VSMOW-SLAP) and δ(18)O(VSMOW-SLAP) measurement results of human hair in previous publications, as needed, to ensure all results on are on the same scales.

  16. Teacher quality: a comparison of National Board-certified and non-Board-certified teachers of deaf students.

    Science.gov (United States)

    Scheetz, Nanci A; Martin, David S

    2006-01-01

    THE STUDY was designed to identify specific components of teacher excellence, focusing initially on the characteristics of the small number of teachers of the deaf who are certified by the National Board for Professional Teaching Standards (NBPTS), then comparing those with the characteristics of other teachers identified as master teachers by university faculty in teacher preparation in deafness. Classroom observation, written lesson plans, teacher questionnaires on beliefs, and content analysis of interactive electronic focus groups were used to compare the two groups of teachers. Results indicated similarities between Board-certified and non-Board-certified master teachers in regard to teacher behaviors and commitment to well-founded pedagogical principles. Differences were found in classroom priorities and in the greater level of interconnectivity expressed by Board-certified teachers as the result of becoming Board certified. Recommendations are made for preparing teachers of deaf students.

  17. Certifying floating-point implementations using Gappa

    CERN Document Server

    De Dinechin, Florent; Melquiond, Guillaume

    2008-01-01

    High confidence in floating-point programs requires proving numerical properties of final and intermediate values. One may need to guarantee that a value stays within some range, or that the error relative to some ideal value is well bounded. Such work may require several lines of proof for each line of code, and will usually be broken by the smallest change to the code (e.g. for maintenance or optimization purpose). Certifying these programs by hand is therefore very tedious and error-prone. This article discusses the use of the Gappa proof assistant in this context. Gappa has two main advantages over previous approaches: Its input format is very close to the actual C code to validate, and it automates error evaluation and propagation using interval arithmetic. Besides, it can be used to incrementally prove complex mathematical properties pertaining to the C code. Yet it does not require any specific knowledge about automatic theorem proving, and thus is accessible to a wide community. Moreover, Gappa may ge...

  18. 氦同位素锂辉石标准物质的研制%Preparation and Calibration of Reference Material for Helium Isotope

    Institute of Scientific and Technical Information of China (English)

    李延河; 宋鹤彬; 乐国量

    2005-01-01

    Two spodumene samples for helium isotope standard were prepared. According to the preparation criterion on first grade national standard materials, homogeneity tests of helium contents and isotope compositions of two samples were carried out using the heat melt method. The homogeneity tests and certification analysis show that 4He contents and 3He/4He ratios of two reference material samples are homogeneous. Afterward two standard samples were distributed to four laboratories for cooperative fixed values. All data of various laboratories submit to normal distribution and not abnormity values. The average values of each laboratory are recommended as values of two spodumene samples for helium isotope standard.

  19. Protein standardization IV: Value transfer procedure for the assignment of serum protein values from a reference preparation to a target material.

    Science.gov (United States)

    Blirup-Jensen, S; Johnson, A M; Larsen, M

    2001-11-01

    A new approach for the assignment of values to serum proteins in a target material using a reference preparation has been developed. The procedure describes the general as well as the practical principles involved in the value assignment (with examples). Two models have been developed: 1) The direct value transfer between serum matrices and 2) the indirect value transfer from a pure protein preparation to a serum protein material. The necessary mathematical equations are developed and explained. The data reduction and statistical evaluation are discussed. The practical procedure (the transfer protocol) is based on six dilutions of the reference preparation assayed together with six dilutions of the target material. In this way imprecision is reduced and the proportionality of the two materials (i.e. the presence or absence of matrix effects) can be assessed directly by evaluating a single regression plot. If no matrix effects are found, the regression line will pass through zero with a slope equal to the ratio of the concentrations of the two materials. The transfer protocol is based on a multiple point value assignment obtained by several measurements a day repeated on several days, an important prerequisite being that all reconstitutions and dilutions are controlled by weighing.

  20. Determination of catechins and caffeine in proposed green tea standard reference materials by liquid chromatography-particle beam/electron ionization mass spectrometry (LC-PB/EIMS).

    Science.gov (United States)

    Castro, Joaudimir; Pregibon, Tara; Chumanov, Kristina; Marcus, R Kenneth

    2010-10-15

    Presented here is the quantitative analysis of green tea NIST standard reference materials (SRMs) via liquid chromatography-particle beam/electron ionization mass spectrometry (LC-PB/EIMS). Three different NIST green tea standard reference materials (SRM 3254 Camellia sinesis Leaves, SRM 3255 C. sinesis Extract and SRM 3256 Green Tea-containing Oral Dosage Form) are characterized for the content of caffeine and a series of catechin species (gallic acid, catechin, epicatechin, epigallocatechin, epicatechin gallate and epigallocatechin gallate (EGCG)). The absolute limits of detection for caffeine and the catechin species were determined to be on the nanogram level. A reversed-phase chromatographic separation of the green tea reference materials was carried out on a commercial C(18) column using a gradient of water (containing 0.1% TFA) and 2:1 methanol:acetonitrile (containing 0.1%TFA) at 0.9mLmin(-1) and an analysis time of 50min. Quantification of caffeine and the catechin species was carried out using the standard addition and internal standard methods, with the latter providing appreciable improvements in precision and recovery.

  1. Simultaneous determination of theobromine, (+)-catechin, caffeine, and (-)-epicatechin in standard reference material baking chocolate 2384, cocoa, cocoa beans, and cocoa butter.

    Science.gov (United States)

    Risner, Charles H

    2008-01-01

    A reverse-phase liquid chromatography analysis is used to access the quantity of theobromine, (+)-catechin, caffeine, and (-)-epicatechin in Standard Reference Material 2384 Baking Chocolate, cocoa, cocoa beans, and cocoa butter using water or a portion of the mobile phase as the extract. The procedure requires minimal sample preparation. Theobromine, (+)-catechin, caffeine, and (-)-epicatechin are detected by UV absorption at 273 nm after separation using a 0.3% acetic acid-methanol gradient (volume fractions) and quantified using external standards. The limit of detection for theobromine, (+)-catechin, caffeine, and (-)-epicatechin averages 0.08, 0.06, 0.06, and 0.06 microg/mL, respectively. The method when applied to Standard Reference Material 2384 Baking Chocolate; baking chocolate reference material yields results that compare to two different, separate procedures. Theobromine ranges from 26000 mg/kg in cocoa to 140 mg/kg in cocoa butter; (+)-catechin from 1800 mg/kg in cocoa to below detection limits of < 32 mg/kg in cocoa butter; caffeine from 2400 mg/kg in cocoa to 400 mg/kg in cocoa butter, and (-)-epicatechin from 3200 mg/kg in cocoa to BDL, < 27 mg/kg, in cocoa butter. The mean recoveries from cocoa are 102.4 +/- 0.6% for theobromine, 100.0 +/- 0.6 for (+)-catechin, 96.2 +/- 2.1 for caffeine, and 106.2 +/- 1.7 for (-)-epicatechin.

  2. Evaluation of reference genes for quantitative real-time PCR in oil palm elite planting materials propagated by tissue culture.

    Directory of Open Access Journals (Sweden)

    Pek-Lan Chan

    Full Text Available BACKGROUND: The somatic embryogenesis tissue culture process has been utilized to propagate high yielding oil palm. Due to the low callogenesis and embryogenesis rates, molecular studies were initiated to identify genes regulating the process, and their expression levels are usually quantified using reverse transcription quantitative real-time PCR (RT-qPCR. With the recent release of oil palm genome sequences, it is crucial to establish a proper strategy for gene analysis using RT-qPCR. Selection of the most suitable reference genes should be performed for accurate quantification of gene expression levels. RESULTS: In this study, eight candidate reference genes selected from cDNA microarray study and literature review were evaluated comprehensively across 26 tissue culture samples using RT-qPCR. These samples were collected from two tissue culture lines and media treatments, which consisted of leaf explants cultures, callus and embryoids from consecutive developmental stages. Three statistical algorithms (geNorm, NormFinder and BestKeeper confirmed that the expression stability of novel reference genes (pOP-EA01332, PD00380 and PD00569 outperformed classical housekeeping genes (GAPDH, NAD5, TUBULIN, UBIQUITIN and ACTIN. PD00380 and PD00569 were identified as the most stably expressed genes in total samples, MA2 and MA8 tissue culture lines. Their applicability to validate the expression profiles of a putative ethylene-responsive transcription factor 3-like gene demonstrated the importance of using the geometric mean of two genes for normalization. CONCLUSIONS: Systematic selection of the most stably expressed reference genes for RT-qPCR was established in oil palm tissue culture samples. PD00380 and PD00569 were selected for accurate and reliable normalization of gene expression data from RT-qPCR. These data will be valuable to the research associated with the tissue culture process. Also, the method described here will facilitate the selection

  3. Nonparametric decision tree: The impact of ISO 9000 on certified and non certified companies Nonparametric decision tree: The impact of ISO 9000 on certified and non certified companies Nonparametric decision tree: The impact of ISO 9000 on certified and non certified companies

    Directory of Open Access Journals (Sweden)

    Joaquín Texeira Quirós

    2013-09-01

    Full Text Available Purpose: This empirical study analyzes a questionnaire answered by a sample of ISO 9000 certified companies and a control sample of companies which have not been certified, using a multivariate predictive model. With this approach, we assess which quality practices are associated to the likelihood of the firm being certified. Design/methodology/approach: We implemented nonparametric decision trees, in order to see which variables influence more the fact that the company be certified or not, i.e., the motivations that lead companies to make sure. Findings: The results show that only four questionnaire items are sufficient to predict if a firm is certified or not. It is shown that companies in which the respondent manifests greater concern with respect to customers relations; motivations of the employees and strategic planning have higher likelihood of being certified. Research implications: the reader should note that this study is based on data from a single country and, of course, these results capture many idiosyncrasies if its economic and corporate environment. It would be of interest to understand if this type of analysis reveals some regularities across different countries. Practical implications: companies should look for a set of practices congruent with total quality management and ISO 9000 certified. Originality/value: This study contributes to the literature on the internal motivation of companies to achieve certification under the ISO 9000 standard, by performing a comparative analysis of questionnaires answered by a sample of certified companies and a control sample of companies which have not been certified. In particular, we assess how the manager’s perception on the intensity in which quality practices are deployed in their firms is associated to the likelihood of the firm being certified.Purpose: This empirical study analyzes a questionnaire answered by a sample of ISO 9000 certified companies and a control sample of companies

  4. Experience of air transport of nuclear fuel material in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, T.; Toguri, D. [Transnuclear, LTD. (AREVA group), Tokyo (Japan); Kawasaki, M. [Japan Nuclear Cycle Development Inst., Muramatsu, Ibaraki (Japan)

    2004-07-01

    Certified Reference Materials (hereafter called as to CRMs), which are indispensable for Quality Assurance and Material Accountability in nuclear fuel plants, are being provided by overseas suppliers to Japanese nuclear entities as Type A package (non-fissile) through air transport. However, after the criticality accident at JCO in Japan, special law defining nuclear disaster countermeasures (hereafter called as to the LAW) has been newly enforced in June 2000. Thereafter, nuclear fuel materials must meet not only to the existing transport regulations but also to the LAW for its transport.

  5. A new organic reference material, L-glutamic acid, USGS41a, for δ13C and δ15N measurements − a replacement for USGS41

    Science.gov (United States)

    Qi, Haiping; Coplen, Tyler B.; Mroczkowski, Stanley J.; Brand, Willi A.; Brandes, Lauren; Geilmann, Heike; Schimmelmann, Arndt

    2016-01-01

    RationaleThe widely used l-glutamic acid isotopic reference material USGS41, enriched in both 13C and 15N, is nearly exhausted. A new material, USGS41a, has been prepared as a replacement for USGS41.MethodsUSGS41a was prepared by dissolving analytical grade l-glutamic acid enriched in 13C and 15N together with l-glutamic acid of normal isotopic composition. The δ13C and δ15N values of USGS41a were directly or indirectly normalized with the international reference materials NBS 19 calcium carbonate (δ13CVPDB = +1.95 mUr, where milliurey = 0.001 = 1 ‰), LSVEC lithium carbonate (δ13CVPDB = −46.6 mUr), and IAEA-N-1 ammonium sulfate (δ15NAir = +0.43 mUr) and USGS32 potassium nitrate (δ15N = +180 mUr exactly) by on-line combustion, continuous-flow isotope-ratio mass spectrometry, and off-line dual-inlet isotope-ratio mass spectrometry.ResultsUSGS41a is isotopically homogeneous; the reproducibility of δ13C and δ15N is better than 0.07 mUr and 0.09 mUr, respectively, in 200-μg amounts. It has a δ13C value of +36.55 mUr relative to VPDB and a δ15N value of +47.55 mUr relative to N2 in air. USGS41 was found to be hydroscopic, probably due to the presence of pyroglutamic acid. Experimental results indicate that the chemical purity of USGS41a is substantially better than that of USGS41.ConclusionsThe new isotopic reference material USGS41a can be used with USGS40 (having a δ13CVPDB value of −26.39 mUr and a δ15NAir value of −4.52 mUr) for (i) analyzing local laboratory isotopic reference materials, and (ii) quantifying drift with time, mass-dependent isotopic fractionation, and isotope-ratio-scale contraction for isotopic analysis of biological and organic materials. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.

  6. Preparation of Interference Filter Reference Materials for ELISA Analytical Instruments%酶标分析仪波长标准物质的研制

    Institute of Scientific and Technical Information of China (English)

    杨欣欣; 张彬; 荀其宁; 拓锐; 胡国星; 潘忠泉

    2015-01-01

    以硫化锌为高折射材料和冰晶石为低反射材料,利用真空镀膜技术、光学极值法检测膜厚技术镀制了窄带全介质干涉滤光片,K9玻璃为薄膜保护层,采用切割、粗磨、精磨、抛光、镀膜等光学工艺制得酶标分析仪波长标准物质,经均匀性、稳定性考核合格后,由紫外可见近红外分光光度计标准装置对标准物质定值。研制的酶标分析仪波长标准物质定制结果扩展不确定度为0.7 nm(k=2),使用方便,量值准确、稳定,技术指标满足酶标分析仪波长示值误差及重复性检定/校准工作的需要。%The interference filter reference materials were made by vacuum coating technology and optical film thickness extremum method which plating zinc sulfide as high refraction materials and cryolite as low reflective materials of narrow–band interference filter, and K9 glass was used as film protective layer. After some optical technology such as cutting, coarse grinding,fine grinding,polishing and plating, the uniformity, stability of interference filter reference materials were examinated by the ultraviolet–visible–near infrared spectrophotometer standard device. According to the results, the deterministic uncertainty of the development reference material was 0.7 nm(k=2). Therefore, the developed interference filter reference materials can meet the verification/calibration requirement for wavelength error and repeatability of ELISA analytical instruments with convenience and stable value.

  7. Water Well Locations - MO 2012 Certified Wells (SHP)

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This data set provides information about wells that are certified by the State of Missouri. The parent data set is the Wellhead Information Management System (WIMS)...

  8. 7 CFR 205.100 - What has to be certified.

    Science.gov (United States)

    2010-01-01

    ... Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) ORGANIC FOODS PRODUCTION ACT PROVISIONS NATIONAL ORGANIC PROGRAM Applicability § 205.100 What has to be certified. (a) Except...

  9. ENERGY STAR Certified Commercial Hot Food Holding Cabinet

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 2.0 ENERGY STAR Program Requirements for Commercial Hot Food Holding Cabinets that are...

  10. A revision in hydrogen isotopic composition of USGS42 and USGS43 human-hair stable isotopic reference materials for forensic science.

    Science.gov (United States)

    Coplen, Tyler B; Qi, Haiping

    2016-09-01

    The hydrogen isotopic composition (δ(2)HVSMOW-SLAP) of USGS42 and USGS43 human hair stable isotopic reference materials, normalized to the VSMOW (Vienna-Standard Mean Ocean Water)-SLAP (Standard Light Antarctic Precipitation) scale, was originally determined with a high temperature conversion technique using an elemental analyzer (TC/EA) with a glassy carbon tube and glassy carbon filling and analysis by isotope-ratio mass spectrometer (IRMS). However, the TC/EA IRMS method can produce inaccurate δ(2)HVSMOW-SLAP results when analyzing nitrogen-bearing organic substances owing to the formation of hydrogen cyanide (HCN), leading to non-quantitative conversion of a sample into molecular hydrogen (H2) for IRMS analysis. A single-oven, chromium-filled, elemental analyzer (Cr-EA) coupled to an IRMS substantially improves the measurement quality and reliability of hydrogen isotopic analysis of hydrogen- and nitrogen-bearing organic material because hot chromium scavenges all reactive elements except hydrogen. USGS42 and USGS43 human hair isotopic reference materials have been analyzed with the Cr-EA IRMS method, and the δ(2)HVSMOW-SLAP values of their non-exchangeable hydrogen fractions have been revised: [Formula: see text] [Formula: see text] where mUr=0.001=‰. On average, these revised δ(2)HVSMOW-SLAP values are 5.7mUr more positive than those previously measured. It is critical that readers pay attention to the δ(2)HVSMOW-SLAP of isotopic reference materials in publications as they may need to adjust the δ(2)HVSMOW-SLAP measurement results of human hair in previous publications to ensure all results are on the same isotope-delta scale.

  11. Physical fitness training reference manual for security force personnel at fuel cycle facilities possessing formula quantities of special nuclear materials

    Energy Technology Data Exchange (ETDEWEB)

    Arzino, P.A.; Caplan, C.S.; Goold, R.E. (California State Univ., Hayward, CA (United States). Foundation)

    1991-09-01

    The recommendations contained throughout this NUREG are being provided to the Nuclear Regulatory Commission (NRC) as a reference manual which can be used by licensee management as they develop a program plan for the safe participation of guards, Tactical Response Team members (TRTs), and all other armed response personnel in physical fitness training and in physical performance standards testing. The information provided in this NUREG will help licensees to determine if guards, TRTs, and other armed response personnel can effectively perform their normal and emergency duties without undue hazard to themselves, to fellow employees, to the plant site, and to the general public. The recommendations in this NUREG are similar in part to those contained within the Department of Energy (DOE) Medical and Fitness Implementation Guide which was published in March 1991. The guidelines contained in this NUREG are not requirements, and compliance is not required. 25 refs.

  12. 角膜接触镜透氧系数参考材料的研究%Reference materials for calibrating oxygen permeability in contact lenses

    Institute of Scientific and Technical Information of China (English)

    文燕; 贾晓航; 方红萍; 何涛; 齐伟明; 郑健

    2015-01-01

    Objective To find a series of reference materials that can be used to calibrate the oxygen permeability (Dk) of contact lenses using polarographic analysis.Methods A control study was performed on two different production samples to create a reference for oxygen permeability coefficients.The Dk of a rigid contact lens material was first measured by a coulometric method, then selections from samples of material were analyzed for Dk values.On the basis of the results, the selected samples were verified for use as reference material.Results For the four Boston rigid contact lens materials, the consistency of oxygen permeability met the requirements when the same production sample was chosen.The Dks, expressed as 2 times the standard deviation at a 95% confidence level, were 2.10%, 0.64%, 1.48%, and 3.16%, respectively, which conformed to the requirement of GB/T11417.7-2012 《Ophthalmic optics.Contact lenses.Part 7: Physicochemical properties test methods》.That is, the Dk reference for the material shall be known within the range of ±5%.Therefore, the average values of the oxygen permeabilities obtained from more than 6 samples can be regarded as the nominal value for a reference material.Conclusion The four Boston rigid contact lens materials (ES, EO, XO and XO2) basically meet the test requirements of oxygen permeability for the soft contact lens material available on the market.%目的 给出一套适合用于校准极谱法测量接触镜透氧系数的参考材料.方法 对照研究.通过库伦法测量硬性接触镜材料透氧系数值,并通过批材料透氧系数离散性分析,判定所选材料是否可作为参考材料.结果 Boston的ES、EO、XO和XO24种硬性接触镜材料,当选择同一生产批时,透氧系数的一致性较符合要求,在置信水平95%状况下用2倍标准差标示时,分别为2.10%、0.64%、1.48%和3.16%,符合GB/T11417.7-2012《眼科光学接触镜第7部分:理化性能试验方法》中关

  13. Antimony speciation analysis in sediment reference materials using high-performance liquid chromatography coupled to hydride generation atomic fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Potin-Gautier, M. [Laboratoire de Chimie Analytique, BioInorganique et Environnement LCABIE (UMR CNRS 3054), Universite de Pau et des pays de l' Adour, 64000 Pau (France); Pannier, F. [Laboratoire de Chimie Analytique, BioInorganique et Environnement LCABIE (UMR CNRS 3054), Universite de Pau et des pays de l' Adour, 64000 Pau (France)]. E-mail: Florence.pannier@univ-pau.fr; Quiroz, W. [Laboratoire de Chimie Analytique, BioInorganique et Environnement LCABIE (UMR CNRS 3054), Universite de Pau et des pays de l' Adour, 64000 Pau (France); Laboratorio de Quimica Analitica y Ambiental, Instituto de Quimica, Pontificia Universidad catolica de Valparaiso (Chile); Pinochet, H. [Laboratorio de Quimica Analitica y Ambiental, Instituto de Quimica, Pontificia Universidad catolica de Valparaiso (Chile); Gregori, I. de [Laboratorio de Quimica Analitica y Ambiental, Instituto de Quimica, Pontificia Universidad catolica de Valparaiso (Chile)

    2005-11-30

    This work presents the development of suitable methodologies for determination of the speciation of antimony in sediment reference samples. Liquid chromatography with a post-column photo-oxidation step and hydride generation atomic fluorescence spectrometry as detection system is applied to the separation and determination of Sb(III), Sb(V) and trimethylantimony species. Post-column decomposition and hydride generation steps were studied for sensitive detection with the AFS detector. This method was applied to investigate the conditions under which speciation analysis of antimony in sediment samples can be carried out. Stability studies of Sb species during the extraction processes of solid matrices, using different reagents solutions, were performed. Results demonstrate that for the extraction yield and the stability of Sb species in different marine sediment extracts, citric acid in ascorbic acid medium was the best extracting solution for antimony speciation analysis in this matrix (between 55% and 65% of total Sb was recovered from CRMs, Sb(III) being the predominant species). The developed method allows the separation of the three compounds within 6 min with detection limits of 30 ng g{sup -1} for Sb(III) and TMSbCl2 and 40 ng g{sup -1} for Sb(V) in sediment samples.

  14. Participatory Communication Referred to Meta-Design Approach through the FleXpeaker™ Application of Innovative Material in Exhibition Design

    Directory of Open Access Journals (Sweden)

    Pei-Hsuan Su

    2016-07-01

    Full Text Available Modelling a communication system in material culture today always involves with objects, people, organizations, activities and interrelationships among them. The researcher suggests bringing together stakeholders engaged to exchange ideas, which the interactions relate to multiple professions and disciplines in a participatory scope of communication system. Owing to the invention of digital media, the status quo of images and sounds has revolutionized and caused changes of the mode of art exhibitions that produce activities and aesthetic concepts in terms of numerical representation, modularity, automation, visual variability and transcoding. Underlying a participatory-design approach, the research emphasizes a co-creative meta-interpretation of museum‟s visitors. In addition, the research delves further into the use of new media-FleXpeaker™ [ITRI], as the carrier. Combining art and design with innovative technology, the research focuses on examining design objects and innovative material which are applied in new media art and exhibition, in the hope to find new angles of participatory interpretation of the “integrated innovation” in curating an exhibition.

  15. Effects of the composition of standard reference material on the accuracy of determinations of {sup 210}Pb and {sup 137}Cs in soils with gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Li, Y., E-mail: yongli32@hotmail.co [State Key Laboratory of Dryland Farming and Soil Erosion in the Loess Plateau, Institute of Soil and Water Conservation, CAS and MWR, Yangling 712100 (China); Institute of Environment and Sustainable Development in Agriculture, CAAS, No. 12 Zhongguancun South Street, Beijing 100081 (China); Geng, X.C.; Yu, H.Q. [Institute of Environment and Sustainable Development in Agriculture, CAAS, No. 12 Zhongguancun South Street, Beijing 100081 (China); Wan, G.J. [State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang (China)

    2011-02-15

    The effect of the composition of the used standard reference material (SRM) on results of determination of fallout radionuclides in soil samples was studied. Using five soil types as SRMs, we measured the specific activity of {sup 210}Pb and {sup 137}Cs in six target samples of Chestnut soil. It was observed that the determination of the {sup 210}Pb activity in the samples depended on the chemical composition of SRMs used to create the efficiency curves. Thus, using SRMs similar in chemical composition to the target samples should improve accuracy in the determination of {sup 210}Pb in environmental samples.

  16. The Reference Materials of Preparation about Salmonella Enteritidis%肠炎沙门氏菌活菌标准物质的研制

    Institute of Scientific and Technical Information of China (English)

    柯璐; 林杰; 戴晓丽; 黄嫦娇; 黄晓蓉

    2015-01-01

    本文以肠炎沙门氏菌为选制菌种,用鸡肉糜混合保护剂配方作为活菌标准物质基质,采用冷冻真空干燥法研制活菌标准物质,共进行了3个批次的研究,每个批次分别制备100份熟制基质和100份生制基质的活菌标准物质。均匀性试验结果表明,生制基质和熟制基质的相对重复性标准差为2.185%和3.596%、相对再现性标准差为2.185%和3.514%,方差分析:P值均大于0.05,表明批次内以及批次间无显著差异。稳定性试验表明,在-20℃条件下,2种活菌标准物质稳定性良好。制备的肠炎沙门氏菌活菌标准物质具有相应的菌种特性,良好的稳定性,对研究同类型标准物质具有一定的参考价值,填补实验室检测质量控制对照物以及标准物质的空缺。%Choose Salmonella enteritidis to the target species , take Chicken mince mixed protectant formula as matrix in Living Bacterium Reference Material , adopt Lyophilization method to develop Living Bacterium Reference Material, for the study of three batches total, each batch prepared the RM containing 100 bottles of Cooked Chicken Matrix and 100 bottles of Raw Chicken Matrix.The results of the uniformity experiment showed that, the repeatability standard deviation of raw chicken matrix and cooked chicken matrix is 2.185%and 3.596%, the reproducibility standard deviation is 2.185%and 3.514%, the results of the Analysis of Variance are P>0.05, it indicated that there was no significant difference between the six batches of RM. Stability experiments showed that the RM stord at -20 ℃, the two kind of RM have good Stability. Conclusion:The Salmonella Enteritidis Living Bacterium Reference Material with corresponding strain properties, good stability, and them have great reference value to study the same type Reference Material , and fill the laboratory testing of quality control contrast and Reference Materials.

  17. Advanced Development of Certified OS Kernels

    Science.gov (United States)

    2015-06-01

    specifications, or other data does not license the holder or any other person or corporation; or convey any rights or permission to manufacture ...they consider every unique integer (up to some predefined maximum, currently 218 ) to represent a different agent or principal. They refer to this integer...is considered to be good engineering when doing large developments, leading to signifi- cantly decreased overall effort – as shown, e.g. in Chlipala

  18. Marked disequilibrium between {sup 234}Th and {sup 230}Th of the {sup 238}U natural radioactive decay chain in IAEA reference materials n. 312, 313 and 314

    Energy Technology Data Exchange (ETDEWEB)

    Colaianni, A. [Dipartimento di Geologia e Geofisica dell' Universita di Bari, Via Orabona, 4 - 70125 Bari (Italy); I.N.F.N. Sezione di Bari, Via G. Amendola, 173 - 70126 Bari (Italy); D' Erasmo, G. [Dipartimento Interateneo di Fisica dell' Universita di Bari, Via G. Amendola, 173 - 70126 Bari (Italy); I.N.F.N. Sezione di Bari, Via G. Amendola, 173 - 70126 Bari (Italy); Pantaleo, A., E-mail: pantaleo@ba.infn.i [I.N.F.N. Sezione di Bari, Via G. Amendola, 173 - 70126 Bari (Italy); Schiavulli, L. [Dipartimento Interateneo di Fisica dell' Universita di Bari, Via G. Amendola, 173 - 70126 Bari (Italy); I.N.F.N. Sezione di Bari, Via G. Amendola, 173 - 70126 Bari (Italy)

    2011-02-15

    A new laboratory for the spectroscopy of natural radioactivity with a good energy resolution is presented. It consists of two distinct parts equipped, respectively, the first one with a HpGe {gamma}-ray detector, whose setup has been already completed, and the second one with large area Silicon {alpha}-ray detectors and a radiochemical section for thin {alpha}-samples preparation, whose setup is yet in progress and will be the argument of a separate work. The {gamma}-ray spectrometer was calibrated by means of IAEA Reference Materials n. 312, 313, 314 and 375. A large difference from the predictions of secular equilibrium emerged between the activities of {sup 234}Th and {sup 230}Th in Materials n. 312, 313 and 314.

  19. Marked disequilibrium between 234Th and 230Th of the 238U natural radioactive decay chain in IAEA reference materials n. 312, 313 and 314.

    Science.gov (United States)

    Colaianni, A; D'Erasmo, G; Pantaleo, A; Schiavulli, L

    2011-02-01

    A new laboratory for the spectroscopy of natural radioactivity with a good energy resolution is presented. It consists of two distinct parts equipped, respectively, the first one with a HpGe γ-ray detector, whose setup has been already completed, and the second one with large area Silicon α-ray detectors and a radiochemical section for thin α-samples preparation, whose setup is yet in progress and will be the argument of a separate work. The γ-ray spectrometer was calibrated by means of IAEA Reference Materials n. 312, 313, 314 and 375. A large difference from the predictions of secular equilibrium emerged between the activities of (234)Th and (230)Th in Materials n. 312, 313 and 314.

  20. 7 CFR 457.145 - Potato crop insurance-certified seed endorsement.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Potato crop insurance-certified seed endorsement. 457... insurance—certified seed endorsement. The Potato Crop Insurance Certified Seed Endorsement Provisions for...) Both FCIC and reinsured policies: Potato Crop Insurance Certified Seed Endorsement 1. In return...

  1. 7 CFR 201.67 - Seed certifying agency standards and procedures.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Seed certifying agency standards and procedures. 201...) FEDERAL SEED ACT FEDERAL SEED ACT REGULATIONS Certified Seed § 201.67 Seed certifying agency standards and procedures. In order to qualify as a seed certifying agency for purposes of section 101(a)(25) of the...

  2. National Board Certified Teachers andTheir Students' Achievement

    Directory of Open Access Journals (Sweden)

    Leslie G. Vandevoort

    2004-09-01

    Full Text Available Contemporary research on teaching indicates that teachers are powerful contributors to students’ academic achievement, though the set and interrelationships of characteristics that make for high-quality and effective teaching have yet to be satisfactorily determined. Nevertheless, on the basis of the extant research and a vision of exemplary teaching, the National Board for Professional Teaching Standards stipulated a definition of a superior teacher. The Board did this without empirical evidence to support their claim that teachers’ who meet the standards set by the Board were superior in promoting academic achievement to those who did not meet those standards. In the 17 years since the founding of the National Board, only a few empirical studies have addressed this important issue. In this study we compare the academic performance of students in the elementary classrooms of 35 National Board Certified teachers and their non-certified peers, in 14 Arizona school districts. Board Certified teachers and their principals provide additional information about these teachers and their schools. Four years of results from the Stanford Achievement Tests in reading, mathematics and language arts, in grades three through six, were analyzed. In the 48 comparisons (four grades, four years of data, three measures of academic performance, using gain scores adjusted for students’ entering ability, the students in the classes of National Board Certified Teachers surpassed students in the classrooms of non-Board certified teachers in almost threequarters of the comparisons. Almost one-third of these differences were statistically significant. In the cases where the students of non-Board certified teachers gained more in an academic year, none of the differences found were statistically significant. Effect size, translated into grade equivalents, informs us that the gains made by students of Board Certified teachers were over one month greater than the

  3. Simultaneous determination of Si, Al and Na concentrations by particle induced gamma-ray emission and applications to reference materials and ceramic archaeological artifacts

    Energy Technology Data Exchange (ETDEWEB)

    Dasari, K.B. [Radiochemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); GITAM Institute of Science, GITAM University, Visakhapatnam 530045 (India); Chhillar, S. [Radiochemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Acharya, R., E-mail: racharya@barc.gov.in [Radiochemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Ray, D.K.; Behera, A. [Ion Beam Laboratory, Institute of Physics, Bhubaneswar 751005 (India); Lakshmana Das, N. [GITAM Institute of Science, GITAM University, Visakhapatnam 530045 (India); Pujari, P.K. [Radiochemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India)

    2014-11-15

    A particle induced gamma ray emission (PIGE) method using 4 MeV proton beam was standardized for simultaneous determination of Si, Al and Na concentrations and has been applied for non-destructive analysis of several reference materials and archaeological clay pottery samples. Current normalized count rates of gamma-rays for the three elements listed above were obtained by an in situ method using Li as internal standard. The paper presents application of the in situ current normalized PIGE method for grouping study of 39 clay potteries, obtained from Rajasthan and Andhra Pradesh states of India. Grouping of artifacts was carried out using the ratios of SiO{sub 2} to Al{sub 2}O{sub 3} concentrations, due to their non volatile nature. Powder samples and elemental standards in pellet forms (cellulose matrix) were irradiated using the 4 MeV proton beam (∼10 nA) from the 3 MV tandem accelerator at IOP Bhubaneswar, and assay of prompt gamma rays was carried out using a 60% relative efficiency HPGe detector coupled to MCA. The concentration ratio values of SiO{sub 2}/Al{sub 2}O{sub 3} indicated that pottery samples fell into two major groups, which are in good agreement with their collection areas. Reference materials from IAEA and NIST were analyzed for quantification of Si, Al and Na concentrations as a part of validation as well as application of PIGE method.

  4. Simultaneous determination of Si, Al and Na concentrations by particle induced gamma-ray emission and applications to reference materials and ceramic archaeological artifacts

    Science.gov (United States)

    Dasari, K. B.; Chhillar, S.; Acharya, R.; Ray, D. K.; Behera, A.; Lakshmana Das, N.; Pujari, P. K.

    2014-11-01

    A particle induced gamma ray emission (PIGE) method using 4 MeV proton beam was standardized for simultaneous determination of Si, Al and Na concentrations and has been applied for non-destructive analysis of several reference materials and archaeological clay pottery samples. Current normalized count rates of gamma-rays for the three elements listed above were obtained by an in situ method using Li as internal standard. The paper presents application of the in situ current normalized PIGE method for grouping study of 39 clay potteries, obtained from Rajasthan and Andhra Pradesh states of India. Grouping of artifacts was carried out using the ratios of SiO2 to Al2O3 concentrations, due to their non volatile nature. Powder samples and elemental standards in pellet forms (cellulose matrix) were irradiated using the 4 MeV proton beam (∼10 nA) from the 3 MV tandem accelerator at IOP Bhubaneswar, and assay of prompt gamma rays was carried out using a 60% relative efficiency HPGe detector coupled to MCA. The concentration ratio values of SiO2/Al2O3 indicated that pottery samples fell into two major groups, which are in good agreement with their collection areas. Reference materials from IAEA and NIST were analyzed for quantification of Si, Al and Na concentrations as a part of validation as well as application of PIGE method.

  5. 48 CFR 52.215-20 - Requirements for Certified Cost or Pricing Data and Data Other Than Certified Cost or Pricing Data.

    Science.gov (United States)

    2010-10-01

    ... Certificate of Current Cost or Pricing Data, as prescribed by FAR 15.406-2. (End of provision) Alternate I... Cost or Pricing Data and Data Other Than Certified Cost or Pricing Data. 52.215-20 Section 52.215-20... Certified Cost or Pricing Data and Data Other Than Certified Cost or Pricing Data. As prescribed in...

  6. 48 CFR 52.215-21 - Requirements for Certified Cost or Pricing Data and Data Other Than Certified Cost or Pricing...

    Science.gov (United States)

    2010-10-01

    ... Contractor shall submit a Certificate of Current Cost or Pricing Data, as prescribed by FAR 15.406-2. (End of... Cost or Pricing Data and Data Other Than Certified Cost or Pricing Data-Modifications. 52.215-21... Requirements for Certified Cost or Pricing Data and Data Other Than Certified Cost or Pricing...

  7. Studies on the chemical conditions and microstructure in the reference bentonites of alternative buffer materials project (ABM) in Aespoe

    Energy Technology Data Exchange (ETDEWEB)

    Muurinen, A. (VTT Technical Research Centre of Finland, Espoo (Finland))

    2009-06-15

    The chemical and microstructural properties of some bentonites used in the ABM project in Aespoe HRL were studied in laboratory experiments. The aim was to obtain information about the materials before they were used in the field experiment and to test the research methods that will be used when the packages of the field experiment are retrieved. The bentonites of interest were MX-80, Deponit CAN, Asha 505 and Friedland Clay. The pH values in the compacted samples prepared from the clay powders and deionized water were about 8 for MX-80, 7 for Deponit and Asha, and 6.5 for Friedland clay. The Eh values in the compacted MX-80, Asha and Deponit samples varied between 100 mV and -100 mV, and in the Friedland clay from 0 mV to 200 mV. The total porosity, chloride porosity and the microstructure were studied in compacted samples prepared from MX-80, Deponit, Asha and Friedland Clay and equilibrated through filter plates with 0.1 M NaCl solution for 12.5 months in aerobic conditions. The dry densities of the samples were approximately 0.7, 1.0, 1.25 and 1.55 g/cm3. XRD and SAXS (Small Angle X-ray Scattering) were used to study the microstructure of the MX-80 and Deponit bentonites. It was obvious that the chloride porosity was lower than the water porosity in all the clays, which indicates the exclusion of anions caused by the negatively charged surfaces. In the XRD measurements on MX-80, Asha and Deponit, the measured basal spaces represented by the diffraction peaks were smaller than the theoretical one assuming a homogenous microstructure. This indicates that there was a substantial amount of water also in the pores, which were not seen by XRD. The SAXS data modelling which considered single discs and stacks of discs proposed that a large fraction of the clay should be considered as single platelets. The fraction of the single discs decreased with the increasing density of the sample. The number of layers in the stacks varied from 4 to 8. By combining the information

  8. Determination of K,Ca and Mg in Black Fungus Certiifed Reference Material by Dry Ashing-ion Chromatography%干灰化-离子色谱法测定木耳标准物质中的钾、钙、镁

    Institute of Scientific and Technical Information of China (English)

    巢静波; 史乃捷; 吴冰

    2014-01-01

    采用离子色谱法对木耳标准物质中的K,Ca,Mg进行测定,对样品消解以及离子色谱分离条件进行了优化。在优化实验条件下,该法对木耳中K,Ca,Mg 3种元素测定结果的相对标准偏差小于1.0%(n=7)。采用该方法对NIST西红柿叶标准物质(SRM1573a)进行测定,测定结果与标准值相符,同时与ICP–OES方法比较验证,两者测定结果一致。对该方法测定结果的不确定度进行了评定,K,Ca,Mg测定结果的相对扩展不确定度(k=2)分别为2.3%,3.3%,1.9%。该方法准确可靠,能够满足标准物质定值的要求。%The contents of potassium,calcium and magnesium in black fungus certified reference material were determined by ion chromatography after dry ashing digestion. Sample digestion and ion chromatography conditions were optimized. Under optimal conditions, the relative standard deviation of detection results of K,Ca and Mg in black fungus was less than 1.0%(n=7). The method was used to determine tomato leaves reference material (NIST SRM1573a), and the results were consistent with standard value. The results detected by the method were compared with those detected by ICP–OES, and they were coincided with each other. The relative expanded uncertainties (k=2) of the results were evaluated, which were 2.3%,3.3%and 1.9%for K,Ca and Mg,respectively. The method is accurate and reliable,and it can meet the requirements of certification of reference material.

  9. Final Report - Certifying the Performance of Small Wind Turbines

    Energy Technology Data Exchange (ETDEWEB)

    Sherwood, Larry [Small Wind Certification Council, Clifton Park, NY (United States)

    2015-08-28

    The Small Wind Certification Council (SWCC) created a successful accredited certification program for small and medium wind turbines using the funding from this grant. SWCC certifies small turbines (200 square meters of swept area or less) to the American Wind Energy Association (AWEA) Small Wind Turbine Performance and Safety Standard (AWEA Standard 9.1 – 2009). SWCC also certifies medium wind turbines to the International Electrical Commission (IEC) Power Performance Standard (IEC 61400-12-1) and Acoustic Performance Standard (IEC 61400-11).

  10. CEH certified ethical hacker : version 8 : study guide

    CERN Document Server

    Oriyano, Sean-Philip

    2014-01-01

    Prepare for the new Certified Ethical Hacker version 8 exam with this Sybex guide Security professionals remain in high demand. The Certified Ethical Hacker is a one-of-a-kind certification designed to give the candidate a look inside the mind of a hacker. This study guide provides a concise, easy-to-follow approach that covers all of the exam objectives and includes numerous examples and hands-on exercises. Coverage includes cryptography, footprinting and reconnaissance, scanning networks, enumeration of services, gaining access to a system, Trojans, viruses, worms, covert channels, and muc

  11. Repackaging and transport of PuO{sub 2} and mox reference materials: the experience at the joint research centre in Ispra

    Energy Technology Data Exchange (ETDEWEB)

    D' Alberti, F.; Lutique, S.; Maluta, F.; Mazzuccato, M. [Joint Research Centre, Via Fermi I-21020, Ispra (Italy)

    2010-07-01

    The Joint Research Centre (JRC) is a Directorate of the European Commission, distributed over sites in Belgium, Germany, Italy, the Netherlands and Spain. Its mission is to provide customer-driven scientific and technical support for the conception, development, implementation and monitoring of EU policies. Peripheral to its fundamental mission are the Decommissioning and radioactive Waste Management (D and WM) activities associated with the JRC nuclear installations constructed and operated during the early years of its research sites. Since the 1980's, the JRC evolving mission has progressively reduced the need for nuclear installations, that must now be decommissioned. The removal of nuclear material from an installation is a prerequisite to start the decommissioning. This paper reports the successful experience at the JRC Italian site (Ispra) on the preparation, packaging and transfer of Plutonium (PuO{sub 2}) and Mixed Oxides (MOX) reference materials used for over twenty years, from the Ispra Performance Laboratory (PERLA) to the original owner abroad. In particular the need for design, licensing and construction of new glove box lines and auxiliary tools as well as the safety provisions for material containers handling and transport are described. (authors)

  12. AICPA standard aids in detecting risk factors for fraud. American Institute of Certified Public Accountants.

    Science.gov (United States)

    Reinstein, A; Dery, R J

    1999-10-01

    The American Institute of Certified Public Accountants' Statement on Auditing Standards (SAS) No. 82, Consideration of Fraud in a Financial Statement Audit, requires independent auditors to obtain reasonable assurance that financial statements are free of material mis-statements caused by error or fraud. SAS No. 82 provides guidance for independent auditors to use to help detect and document risk factors related to potential fraud. But while SAS No. 82 suggests how auditors should assess the potential for fraud, it does not expand their detection responsibility. Accordingly, financial managers should discuss thoroughly with auditors the scope and focus of an audit as a means to further their compliance efforts.

  13. 漫透射视觉密度计密度片标准物质的研制%Preparation of Reference Material for Diffuse Transmission Visual Densitometer

    Institute of Scientific and Technical Information of China (English)

    程康; 孔炜; 邱黛君; 郭波; 张瑞锋; 仵欣

    2015-01-01

    以工业射线胶片为主材,经过曝光和暗室处理等工艺,制备检定校准漫透射视觉密度计用的密度片标准物质。密度片的级数达到24级、光学密度值范围为0.03~5.00,密度片的量值、均匀性及光谱特性等参数均优于相关规程对标准密度片的规定参数,可广泛应用于漫透射视觉密度计的检定校准工作。%By using industrial radiographic films for basic material, the reference step tablet for diffuse transmission visual densitometer was developed after the process of exposure and darkroom processing technology. The step tablet had 24 levels and the range of optical density value was 0.03–5.00. The density value,uniformity and spectral characteristics of the reference step tablet were much better than the demand parameters of related rules, which could be widely used for verification and calibration of diffuse transmission visual densitometers.

  14. Characterisation of a natural quartz crystal as a reference material for microanalytical determination of Ti, Al, Li, Fe, Mn, Ga and Ge

    Science.gov (United States)

    Audetat, Andreas; Garbe-Schonberg, Dieter; Kronz, Andreas; Pettke, Thomas; Rusk, Brian G.; Donovan, John J.; Lowers, Heather

    2015-01-01

    A natural smoky quartz crystal from Shandong province, China, was characterised by laser ablation ICP-MS, electron probe microanalysis (EPMA) and solution ICP-MS to determine the concentration of twenty-four trace and ultra trace elements. Our main focus was on Ti quantification because of the increased use of this element for titanium-in-quartz (TitaniQ) thermobarometry. Pieces of a uniform growth zone of 9 mm thickness within the quartz crystal were analysed in four different LA-ICP-MS laboratories, three EPMA laboratories and one solution-ICP-MS laboratory. The results reveal reproducible concentrations of Ti (57 ± 4 μg g-1), Al (154 ± 15 μg g-1), Li (30 ± 2 μg g-1), Fe (2.2 ± 0.3 μg g-1), Mn (0.34 ± 0.04 μg g-1), Ge (1.7 ± 0.2 μg g-1) and Ga (0.020 ± 0.002 μg g-1) and detectable, but less reproducible, concentrations of Be, B, Na, Cu, Zr, Sn and Pb. Concentrations of K, Ca, Sr, Mo, Ag, Sb, Ba and Au were below the limits of detection of all three techniques. The uncertainties on the average concentration determinations by multiple techniques and laboratories for Ti, Al, Li, Fe, Mn, Ga and Ge are low; hence, this quartz can serve as a reference material or a secondary reference material for microanalytical applications involving the quantification of trace elements in quartz.

  15. Nurse Practitioners, Physician Assistants and Certified Nurse Midwives in California.

    Science.gov (United States)

    California Univ., San Francisco. Center for California Health Workforce Studies.

    Surveys were mailed to all nurse practitioners (NPs), physician assistants (PAs) and certified nurse midwives (CNMs) registered in California, asking questions about education, labor force participation, specialty, and location and type of practice site, as well as the demographic characteristics of these professionals and their patients. Response…

  16. Relevant or determinant: Importance in certified sustainable food consumption

    NARCIS (Netherlands)

    Dam, van Y.K.; Trijp, van J.C.M.

    2013-01-01

    Perceived relevance and determinance are two distinct constructs, underlying the overall concept of attribute importance. The present study proposes a survey based measure of attribute determinance. Based on construal level theory it is argued and empirically shown that actual choices of certified

  17. 31 CFR 353.55 - Individuals authorized to certify.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Individuals authorized to certify. 353.55 Section 353.55 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued... imprint of either the corporate seal of the institution or of the issuing or paying agent's stamp....

  18. 31 CFR 360.55 - Individuals authorized to certify.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Individuals authorized to certify. 360.55 Section 360.55 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued... imprint of either the corporate seal of the institution or of the issuing or paying agent's stamp....

  19. 31 CFR 315.55 - Individuals authorized to certify.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Individuals authorized to certify. 315.55 Section 315.55 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued... authenticated by a legible imprint either of a corporate stamp of the institution or of the issuing or...

  20. Certifying and reasoning on cost annotations of functional programs

    CERN Document Server

    Amadio, Roberto M

    2011-01-01

    We present a so-called labelling method to insert cost annotations in a higher-order functional program, to certify their correctness with respect to a standard compilation chain to assembly code, and to reason on them in a higher-order Hoare logic.

  1. The Effectiveness of National Board Certified Teachers: Policy Implications

    Science.gov (United States)

    Okpala, Comfort O.; James, Ioney; Hopson, Linda

    2009-01-01

    In this mixed-method research study, data from public school personnel were used to determine the professional preparation of teachers through the National Board Certification process. The major goals of the study were to (a) analyze the perceptions of public school principals on the effectiveness of National Board certified teachers, (b) analyze…

  2. Becoming a National Board Certified Teacher: One Teacher's Perspective

    Science.gov (United States)

    Burns, John

    2007-01-01

    Reflecting on one's practice, whether it is a conversation with a single student, a lesson, or a unit plan, is the surest way for a teacher to improve. Going through the process of becoming a National Board Certified Teacher (NBCT) is a journey of reflective practice. The National Board of Professional Teaching Standards (NBPTS) is a nonprofit,…

  3. Software testing an ISTQB-BCS certified tester foundation guide

    CERN Document Server

    Hambling, Brian; Samaroo, Angelina; Thompson, Geoff; Williams, Peter; Hambling, Brian

    2015-01-01

    This practical guide provides insight into software testing, explaining the basics of the testing process and how to perform effective tests. It provides an overview of different techniques and how to apply them. It is the best-selling official textbook of the ISTQB-BCS Certified Tester Foundation Level.

  4. Job Satisfaction of Certified Nurse Midwives: An Examination

    Science.gov (United States)

    Hampton, Gerald M.; Peterson, Robin T.

    2012-01-01

    Health care providers face pressure to reduce costs and enhance patient satisfaction. One approach is to employ primary care providers such as nurse practitioners, physician assistants, and certified nurse midwives. Since there is a positive relationship between job satisfaction and patient satisfaction, positive job satisfaction on the part of…

  5. Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China.

    Science.gov (United States)

    Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li'an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling

    2016-03-01

    A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box-Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China.

  6. Certification of Charpy V-notch Reference Test Pieces of 80 J Nominal Absorbed Energy (ERM®-FA015x and ERM®-FA015y)

    OpenAIRE

    LAMBERTY MARIE ANDREE; Dean, Alan; Roebben, Gert

    2011-01-01

    This certification report describes the processing and characterisation of ERM®-FA015x and ERM®-FA015y, two batches of Charpy V-notch certified reference test pieces. Sets of five of these test pieces are used for the verification of pendulum impact test machines according to EN 10045-2 (Charpy impact test on metallic materials, Part 2. Method for the verification of impact testing machines) or according to ISO 148-2 (Metallic materials - Charpy pendulum impact test – Part 2: Verification of ...

  7. 同位素稀释-ICPMS法测定地质标准物质中铂族元素%Determination of Platinum-group Elements in the Geological Standard Reference Materials by Isotope Dilution-ICPMS

    Institute of Scientific and Technical Information of China (English)

    胡明月; 何红蓼

    2005-01-01

    Platinum group elements (PGEs) includes platinum, palladium, iridium, osmium, rhodium and ruthenium. It has very high economic and scientific value in the field of geoscience and environmental science. But the analysis data referred by the different lab are very disperse because of the difficulty of the determination of PGEs. It makes very difficult to fix the value of the PGEs in the standard reference materials. In the article, the values of the PGEs in the standard reference materials of ocean sediment are determined by isotope dilution technique and dependable values of these elements are provided.

  8. Teacher Quality: A Comparison of National Board--Certified and Non--Board--Certified Teachers of Deaf Students

    Science.gov (United States)

    Scheetz, Nanci A.; Martin, David S.

    2006-01-01

    The study was designed to identify specific components of teacher excellence, focusing initially on the characteristics of the small number of teachers of the deaf who are certified by the National Board for Professional Teaching Standards (NBPTS), then comparing those with the characteristics of other teachers identified as master teachers by…

  9. What is in a label? Rainforest-Alliance certified banana production versus non-certified conventional banana production

    NARCIS (Netherlands)

    Bellamy, Angelina Sanderson; Svensson, Ola; Brink, van den Paul J.; Tedengren, Michael

    2016-01-01

    Export banana production in Latin America is pesticide intensive, receiving much negative publicity regarding human health problems and environmental degradation. The Rainforest Alliance (RA) certification scheme was established to certify farms that met a number of social, occupation health and

  10. Implementation of a reference standard and proficiency testing programme by the World Wide Antimalarial Resistance Network (WWARN

    Directory of Open Access Journals (Sweden)

    Barnes Karen I

    2010-12-01

    Full Text Available Abstract Background The Worldwide Antimalarial Resistance Network (WWARN is a global collaboration to support the objective that anyone affected by malaria receives effective and safe drug treatment. The Pharmacology module aims to inform optimal anti-malarial drug selection. There is an urgent need to define the drug exposure - effect relationship for most anti-malarial drugs. Few anti-malarials have had their therapeutic blood concentration levels defined. One of the main challenges in assessing safety and efficacy data in relation to drug concentrations is the comparability of data generated from different laboratories. To explain differences in anti-malarial pharmacokinetics in studies with different measurement laboratories it is necessary to confirm the accuracy of the assay methods. This requires the establishment of an external quality assurance process to assure results that can be compared. This paper describes this process. Methods The pharmacology module of WWARN has established a quality assurance/quality control (QA/QC programme consisting of two separate components: 1. A proficiency testing programme where blank human plasma spiked with certified reference material (CRM in different concentrations is sent out to participating bioanalytical laboratories. 2. A certified reference standard programme where accurately weighed amounts of certified anti-malarial reference standards, metabolites, and internal standards are sent to participating bioanalytical and in vitro laboratories. Conclusion The proficiency testing programme is designed as a cooperative effort to help participating laboratories assess their ability to carry out drug analysis, resolve any potential problem areas and to improve their results - and, in so doing, to improve the quality of anti-malarial pharmacokinetic data published and shared with WWARN. By utilizing the same source of standards for all laboratories, it is possible to minimize bias arising from poor

  11. Biomedical Engineering Desk Reference

    CERN Document Server

    Ratner, Buddy D; Schoen, Frederick J; Lemons, Jack E; Dyro, Joseph; Martinsen, Orjan G; Kyle, Richard; Preim, Bernhard; Bartz, Dirk; Grimnes, Sverre; Vallero, Daniel; Semmlow, John; Murray, W Bosseau; Perez, Reinaldo; Bankman, Isaac; Dunn, Stanley; Ikada, Yoshito; Moghe, Prabhas V; Constantinides, Alkis

    2009-01-01

    A one-stop Desk Reference, for Biomedical Engineers involved in the ever expanding and very fast moving area; this is a book that will not gather dust on the shelf. It brings together the essential professional reference content from leading international contributors in the biomedical engineering field. Material covers a broad range of topics including: Biomechanics and Biomaterials; Tissue Engineering; and Biosignal Processing* A hard-working desk reference providing all the essential material needed by biomedical and clinical engineers on a day-to-day basis * Fundamentals, key techniques,

  12. Characterization of national food agency shrimp and plaice reference materials for trace elements and arsenic species by atomic and mass spectrometric techniques

    DEFF Research Database (Denmark)

    Larsen, Erik Huusfeldt; Pedersen, Gitte Alsing; McLaren, J. W.

    1997-01-01

    , drying, milling and sieving to collect the fraction of particles less than 150 mu m in sizer In this fraction the trace elements were homogeneously distributed using a 400 mg sample intake for analysis, The total track element concentrations were determined by graphite furnace and cold vapour atomic...... absorption spectrometry, inductively coupled plasma mass spectrometry (ICP-MS) and isotope dilution ICP-MS. The contents of arsenobetaine and the tetramethylarsonium ion were determined by cation exchange high performance liquid chromatography (HPLC) coupled with ICP-MS, or coupled with ion-spray (IS) tandem...... mass spectrometry (MS/MS) for qualitative verification, Based on a rigorous statistical analysis of the analytical data using the DANREF software, it was decided to assign certified values for mercury, cadmium and arsenic in the NFA Shrimp, and mercury, selenium and arsenic in the NFA Plaice...

  13. 42 CFR 410.77 - Certified nurse-midwives' services: Qualifications and conditions.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Certified nurse-midwives' services: Qualifications... Medical and Other Health Services § 410.77 Certified nurse-midwives' services: Qualifications and conditions. (a) Qualifications. For Medicare coverage of his or her services, a certified nurse-midwife...

  14. 42 CFR 414.54 - Payment for certified nurse-midwives' services.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Payment for certified nurse-midwives' services. 414... Physicians and Other Practitioners § 414.54 Payment for certified nurse-midwives' services. For services...)(1)(K) of the Act for the payment of certified nurse-midwife services may not exceed 65 percent...

  15. 13 CFR 121.705 - Must a business concern self-certify its size status?

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Must a business concern self-certify its size status? 121.705 Section 121.705 Business Credit and Assistance SMALL BUSINESS...-certify its size status? (a) A firm must self-certify that it currently meets the eligibility...

  16. 9 CFR 355.29 - Composition of certified products for dogs, cats, and other carnivora.

    Science.gov (United States)

    2010-01-01

    ... dogs, cats, and other carnivora. 355.29 Section 355.29 Animals and Animal Products FOOD SAFETY AND... PRODUCTS INSPECTION AND VOLUNTARY INSPECTION AND CERTIFICATION CERTIFIED PRODUCTS FOR DOGS, CATS, AND OTHER... Composition of Certified Products § 355.29 Composition of certified products for dogs, cats, and...

  17. 40 CFR 33.206 - Is there a list of certified MBEs and WBEs?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Is there a list of certified MBEs and... PROTECTION AGENCY PROGRAMS Certification § 33.206 Is there a list of certified MBEs and WBEs? EPA OSDBU will maintain a list of certified MBEs and WBEs on EPA OSDBU's Home Page on the Internet. Any interested...

  18. 7 CFR 785.4 - Grants to certified State mediation programs.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Grants to certified State mediation programs. 785.4..., DEPARTMENT OF AGRICULTURE SPECIAL PROGRAMS CERTIFIED STATE MEDIATION PROGRAM § 785.4 Grants to certified State mediation programs. (a) Eligibility. To be eligible to receive a grant, a State mediation...

  19. 48 CFR 52.215-10 - Price Reduction for Defective Certified Cost or Pricing Data.

    Science.gov (United States)

    2010-10-01

    ... complete, accurate, and current as certified in its Certificate of Current Cost or Pricing Data; (2) A... complete, accurate, and current as certified in the Contractor's Certificate of Current Cost or Pricing... been modified even if accurate, complete, and current certified cost or pricing data had been...

  20. 7 CFR 201.71 - Establishing the source of all classes of certified seed.

    Science.gov (United States)

    2010-01-01

    ... seed. 201.71 Section 201.71 Agriculture Regulations of the Department of Agriculture (Continued... (CONTINUED) FEDERAL SEED ACT FEDERAL SEED ACT REGULATIONS Certified Seed § 201.71 Establishing the source of all classes of certified seed. The certifying agency shall have evidence of the class and source...

  1. 7 CFR 201.74 - Labeling of all classes of certified seed.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Labeling of all classes of certified seed. 201.74... SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) FEDERAL SEED ACT FEDERAL SEED ACT REGULATIONS Certified Seed § 201.74 Labeling of all classes of certified seed....

  2. 7 CFR 201.70 - Limitations of generations for certified seed.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Limitations of generations for certified seed. 201.70... SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) FEDERAL SEED ACT FEDERAL SEED ACT REGULATIONS Certified Seed § 201.70 Limitations of generations for certified...

  3. 7 CFR 201.72 - Production of all classes of certified seed.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Production of all classes of certified seed. 201.72... SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) FEDERAL SEED ACT FEDERAL SEED ACT REGULATIONS Certified Seed § 201.72 Production of all classes of certified...

  4. Certifying qubit operations below the fault tolerance threshold

    CERN Document Server

    Blume-Kohout, Robin; Nielsen, Erik; Rudinger, Kenneth; Mizrahi, Jonathan; Fortier, Kevin; Maunz, Peter

    2016-01-01

    Quantum information processors promise fast algorithms for problems inaccessible to classical computers. But since qubits are noisy and error-prone, they will depend on fault-tolerant quantum error correction (FTQEC) to compute reliably. Quantum error correction can protect against general noise if -- and only if -- the error in each physical qubit operation is smaller than a certain threshold. The threshold for general errors is quantified by their diamond norm. Until now, qubits have been assessed primarily by randomized benchmarking (RB), which reports a different "error rate" that is not sensitive to all errors, cannot be compared directly to diamond norm thresholds, and cannot efficiently certify a qubit for FTQEC. We use gate set tomography (GST) to completely characterize the performance of a trapped-Yb$^+$-ion qubit and certify it rigorously as suitable for FTQEC by establishing that its diamond norm error rate is less than $6.7\\times10^{-4}$ with $95\\%$ confidence.

  5. [Certified occupational physician system of Japan Society for Occupational Health].

    Science.gov (United States)

    Ogami, Akira; Higashi, Toshiaki

    2013-10-01

    Certified Occupational Physician System (COPS) of Japan Society for Occupational Health has been in existence for 21 years, since 1992. UOEH has supported this system as a secretary general. In this report, we review the 2012 revision of COPS. With the new title of Certified Associate Occupational Physician (CAOP), this revision was established to produce well-educated and experienced occupational physicians. The title of COP is not competitive but independent to other titles such as occupational physician, medical advisor in industrial health or industrial health consultant. In addition, the aim of COPS is not the replacement to these existing systems. Furthermore, the COP should be active in industrial and occupational health, and should cooperate with existing systems through the sharing of experience and knowledge.

  6. Fault tolerant quantum random number generator certified by Majorana fermions

    Science.gov (United States)

    Deng, Dong-Ling; Duan, Lu-Ming

    2013-03-01

    Braiding of Majorana fermions gives accurate topological quantum operations that are intrinsically robust to noise and imperfection, providing a natural method to realize fault-tolerant quantum information processing. Unfortunately, it is known that braiding of Majorana fermions is not sufficient for implementation of universal quantum computation. Here we show that topological manipulation of Majorana fermions provides the full set of operations required to generate random numbers by way of quantum mechanics and to certify its genuine randomness through violation of a multipartite Bell inequality. The result opens a new perspective to apply Majorana fermions for robust generation of certified random numbers, which has important applications in cryptography and other related areas. This work was supported by the NBRPC (973 Program) 2011CBA00300 (2011CBA00302), the IARPA MUSIQC program, the ARO and the AFOSR MURI program.

  7. Certified reduced basis methods for parametrized partial differential equations

    CERN Document Server

    Hesthaven, Jan S; Stamm, Benjamin

    2016-01-01

    This book provides a thorough introduction to the mathematical and algorithmic aspects of certified reduced basis methods for parametrized partial differential equations. Central aspects ranging from model construction, error estimation and computational efficiency to empirical interpolation methods are discussed in detail for coercive problems. More advanced aspects associated with time-dependent problems, non-compliant and non-coercive problems and applications with geometric variation are also discussed as examples.

  8. Brazilian Board of Orthodontics and Facial Orthopedics: certifying excellence

    OpenAIRE

    Lima Filho,Roberto M. A.; VogelI, Carlos Jorge; Zen,Estélio; Bolognese,Ana Maria; Mucha,José Nelson; Araújo,Telma Martins de

    2011-01-01

    p. 148-157 The Brazilian Board of Orthodontics and Facial Orthopedics (BBO) is the institution that certifies the standards of clinical excellence in the practice of this specialty. This article describes the history of BBO's creation and the examination structure and phases to obtain the BBO Certification. It also presents a detailed report of the first exam applied in Brazil. Its purpose is to expand the knowledge, among professionals in the area, about the importance of BBO Certificatio...

  9. [The newly certified 105 Japanese medical technologists in clinical microbiology].

    Science.gov (United States)

    Kumasaka, Kazunari

    2002-05-01

    Interest in quality assurance(QA) in clinical laboratories in Japan has increased over the past 30 years. We have however been lagging behind countries such as the USA, Canada and the UK in QA of clinical microbiology. The main problem of QA in Japan is human resources. There are only about 400 laboratory physicians certified by the Japanese Society of Laboratory Medicine(JSLM). Almost no academics in microbiology are interested in QA and they mostly lack clinical competence. There is a small number of faculty positions, and promotions are mostly based on research productivity while medical graduates are increasingly drawn to bench work for basic, short-term research. The Japanese Society for Clinical Microbiology (JSCM) was established in 1990 in order to promote the development of clinical microbiology and its relevant fields in Japan. And 2001 was a milestone in sustained efforts of the JSLM to initiate qualifying examinations of medical technologists(MT) in clinical microbiology. 105 MT in clinical microbiology were newly certified by the Joint Committee of JSCM, JSLM, Japanese Association of Medical Technologists (JAMT) and College of Clinical Pathology of Japan(CCPJ). The certified MTs have appropriate educational background and are well motivated. With good on-the-job training, they are expected to perform effectively various tasks, including laboratory management. Recent radical changes in the health care delivery system have also had serious implications on laboratory services and QA of microbiological tests. The primary goal of the clinical microbiology laboratory is to provide accurate diagnostic testing and high-quality service at a low cost for its customers. It is believed that the Joint Committee and the newly certified MTs will contribute to narrowing the gap between Japan and other countries in clinical microbiology.

  10. The potential of MIR spectra to certify milk geographic origin

    OpenAIRE

    Dale, Laura-Monica; Laine, Aurélie; Goubau, Amaury; Bel Mabrouk, Hana; Hammami, Hedi; Gengler, Nicolas

    2013-01-01

    Protecting and supporting local production systems, regional authorities, as well as producers, give a very important role to milk quality. Therefore, this study was aimed to investigate the potential of mid-infrared spectroscopy (MIR) for certifying the geographic origin of milk. Because milk MIR spectral databases and extra phenotypes (breed, testday, livestock herd and origin appellation of traditional products) were available in the Belgium Walloon Region via European project OptiMIR (INT...

  11. Certified Nursing Assistants’ Explanatory Models of Nursing Home Resident Depression

    OpenAIRE

    Piven, Mary Lynn; Anderson, Ruth A.; Colón-Emeric, Cathleen S.; Sandelowski, Margarete

    2008-01-01

    In this study, we explored how Certified Nursing Assistants (CNAs) understood resident depression. Interviews with 18 CNAs, working in two nursing homes were guided by Kleinman’s Explanatory Models of Illness framework. Interview data were content analyzed and CNAs’ descriptions of depression were compared to the MDS 2.0 Mood Screen and to DSM-IV-TR Depression Criteria. CNAs identified causes, signs, and symptoms of depression, but they were unsure about the duration and normalcy of depressio...

  12. Climate change and WTO : boundary mediation on certified emission reductions

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ho Cheol

    2011-07-15

    This book mentions climate change and WTO with is climate change true? International effort for reduce of greenhouse gas with UNFCCC, Kyoto protocol, Copenhagen Accord and Cancun Agreement, WTO norm, discussion on introduction of boundary mediation on certified emission reductions, analysis on regulation related WTO norm, violation of regulation on border measure of prohibition, violation of principle on GATT, justification, except through Article 20 of GATT, assessment of policy and supplementation on the law.

  13. Concurrent determination of 237Np and Pu isotopes using ICP-MS: analysis of NIST environmental matrix standard reference materials 4357, 1646a, and 2702.

    Science.gov (United States)

    Matteson, Brent S; Hanson, Susan K; Miller, Jeffrey L; Oldham, Warren J

    2015-04-01

    An optimized method was developed to analyze environmental soil and sediment samples for (237)Np, (239)Pu, and (240)Pu by ICP-MS using a (242)Pu isotope dilution standard. The high yield, short time frame required for analysis, and the commercial availability of the (242)Pu tracer are significant advantages of the method. Control experiments designed to assess method uncertainty, including variation in inter-element fractionation that occurs during the purification protocol, suggest that the overall precision for measurements of (237)Np is typically on the order of ± 5%. Measurements of the (237)Np concentration in a Peruvian Soil blank (NIST SRM 4355) spiked with a known concentration of (237)Np tracer confirmed the accuracy of the method, agreeing well with the expected value. The method has been used to determine neptunium and plutonium concentrations in several environmental matrix standard reference materials available from NIST: SRM 4357 (Radioactivity Standard), SRM 1646a (Estuarine Sediment) and SRM 2702 (Inorganics in Marine Sediment).

  14. Estimation of mercury speciation in soil standard reference materials with different extraction methods by ion chromatography coupled with ICP-MS.

    Science.gov (United States)

    Park, Misun; Yoon, Hyeon; Yoon, Cheolho; Yu, Jae-Young

    2011-01-01

    Analytical methods for the speciation of mercury, based on microwave extraction and sonication extraction, have been tested to determine the inorganic mercury and methyl mercury contents in two standard soil reference materials: SRM 2710 Montana Soil and BCR 580 estuarine sediment. Prior to applying the speciation extraction methods, the mineral compositions were analyzed via XRD analysis, with SRM 2710 shown to be composed mostly of aluminum silicate minerals, while carbonate minerals were the major constituent in BCR 580. Two extraction methods, microwave and sonication, were tested for the analysis and recovery efficiency of total mercury. The accuracy and efficiency of each extraction method was also compared. In the analysis of total mercury, the microwave extraction method, with using methanol and HCl as extractants, was better for SRM2710, while the application of the sonication extraction method was more efficient for the calcite-based BCR 580. The results showed good separation and recovery efficiencies, with values reaching 100% of those estimated. The sonication method was selected for the speciation of mercury, especially in BCR 580. An extraction solution comprising of a 1:1 mixture of methanol and HCl was used for the sonication extraction of BCR 580, with the resulting extractants analyzed by IC-HG-ICP-MS for methyl mercury and inorganic mercury. As a simple, rapid, sensitive, and accurate method, sonication extraction was found to be satisfactory.

  15. References on Sustainable Buildings

    OpenAIRE

    2005-01-01

    This web site is developed with the aim to promote sustainable design and planning of buildings. Selected references including books, reports, audio/visual materials and journals are listed. Most of the materials can be found in the HKU Libraries. To facilitate retrieval, links are provided to the library catalogue system for further information and study.

  16. Reference Revolutions.

    Science.gov (United States)

    Mason, Marilyn Gell

    1998-01-01

    Describes developments in Online Computer Library Center (OCLC) electronic reference services. Presents a background on networked cataloging and the initial implementation of reference services by OCLC. Discusses the introduction of OCLC FirstSearch service, which today offers access to over 65 databases, future developments in integrated…

  17. COMPARATIVE ANALYSIS OF INNOVATION PERFORMANCE IN CERTIFIED FIRMS IN MONTENEGRO AND REPUBLIC OF SRPSKA

    Directory of Open Access Journals (Sweden)

    Zdravko Krivokapic

    2014-03-01

    Full Text Available Research subjects of this study are certified companies and their commitment to innovation, as well as their own development and implementation of innovation. Certified companies are those companies that have set one or more standards: ISO 9001:2008, ISO 14001: 2004, HACCP, OHSAS 18001, ISO 17025:2006, ISO 27001. The research is based on 60 certified companies in Montenegro and 165 certified companies Republic of Srpska. The research was conducted at certified companies from all regions, for every activity and sizes. For this purpose it was used questionnaire with 91 questions and it was filled in like interview.

  18. 转基因玉米质粒分子国家标准样品的构建%Research on Molecular DNA Reference Material for GM Maize

    Institute of Scientific and Technical Information of China (English)

    郑秋月; 曹际娟; 徐君怡; 赵昕

    2012-01-01

    本文研制转基因玉米常见的4个品系:BT11、MON810、NK603和T25质粒分子国家标准样品.研究重点包括目标序列和内标准基因序列的选择和扩增、标准样品定值和分析等.均匀性和稳定性结果表明,所研制的转基因玉米4个品系标准样品均匀稳定.采用PicoGreen DNA分子荧光定量方法定值标准样品.多家单位合作定值,确定标准样品的标准值及其不确定度.所研制的转基因玉米质粒分子标准样品获得了国家标准样品证书,适用于转基因产品的定量和定性测定.%We devoloped the research of GM Maize BT1U MON810, NK603 and T25 Line Molecular DNA Reference Material. Research priorities include the target sequence and the internal standard gene sequences selection and amplification, reference Material definite value and analysis. The result of uniformity and stability test showed that the Reference Materials were uniformity and stability. The value of Reference Material was difinited by PicoGreen DNA fluorescence quantitative method. The standard value and uncertainty of Reference Material was difinited by many units cooperation.The Molecular DNA Reference Material with certificate has the important value on the quantitative and qualitative detection of GMO.

  19. Electrical engineer's reference book

    CERN Document Server

    Laughton, M A

    1985-01-01

    Electrical Engineer's Reference Book, Fourteenth Edition focuses on electrical engineering. The book first discusses units, mathematics, and physical quantities, including the international unit system, physical properties, and electricity. The text also looks at network and control systems analysis. The book examines materials used in electrical engineering. Topics include conducting materials, superconductors, silicon, insulating materials, electrical steels, and soft irons and relay steels. The text underscores electrical metrology and instrumentation, steam-generating plants, turbines

  20. 多接收电感耦合等离子体质谱法测定Nd同位素标准物质%Nd Isotopic Measurements of Reference Materials Using Multicollector-Inductively Coupled Plasma Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    唐索寒; 何学贤; 王进辉; 朱祥坤

    2005-01-01

    The precision and accuracy of Nd isotope analysis using multicollector-inductively coupled plasma mass spectrometry (MC-ICPMS) is verified through repeated measurements of standard reference materials of JMC Nd2O3 and GBW04419. A mixed solution of Nd separated from hundreds of geological samples is measured for 143Nd/144Nd ratio, which produces excellent long-term repeatability. This solution, named as CAGS-Nd-1, can be used as an in-house reference material for monitoring instrument stability during Nd isotope measurements.

  1. Reference characterisation of sound speed and attenuation of the IEC agar-based tissue-mimicking material up to a frequency of 60 MHz.

    Science.gov (United States)

    Rajagopal, Srinath; Sadhoo, Neelaksh; Zeqiri, Bajram

    2015-01-01

    To support the development of clinical applications of high-frequency ultrasound, appropriate tissue-mimicking materials (TMMs) are required whose acoustic properties have been measured using validated techniques. This paper describes the characterisation of the sound speed (phase velocity) and attenuation coefficient of the International Electrotechnical Commission (IEC) agar-based TMM over the frequency range 1 to 60 MHz. Measurements implemented a broadband through-transmission substitution immersion technique over two overlapping frequency ranges, with co-axially aligned 50 MHz centre-frequency transducers employed for characterisation above 15 MHz. In keeping with usual practice employed within the technical literature, thin acoustic windows (membranes) made of 12-μm-thick Mylar protected the TMM from water damage. Various important sources of uncertainty that could compromise measurement accuracy have been identified and evaluated through a combination of experimental studies and modelling. These include TMM sample thickness, measured both manually and acoustically, and the influence of interfacial losses that, even for thin protective membranes, are significant at the frequencies of interest. In agreement with previous reports, the attenuation coefficient of the IEC TMM exhibited non-linear frequency dependence, particularly above 20 MHz, yielding a value of 0.93 ± 0.04 dB cm(-1) MHz(-1) at 60 MHz, derived at 21 ± 0.5°C. For the first time, phase velocity, measured with an estimated uncertainty of ±3.1 m s(-1), has been found to be dispersive over this extended frequency range, increasing from 1541 m s(-1) at 1 MHz to 1547 m s(-1) at 60 MHz. This work will help standardise acoustic property measurements, and establishes a reference measurement capability for TMMs underpinning clinical applications at elevated frequencies.

  2. Produção de material de referência para ensaio de proficiência de enumeração de Bacillus cereus em leite / Preparation of reference material for proficiency test for enumeration of Bacillus cereus in milk

    Directory of Open Access Journals (Sweden)

    Marcelo Luiz Lima Brandão

    2014-02-01

    Full Text Available A participação em ensaios de proficiência é essencial para que um laboratório de ensaio possa ter seu desempenho avaliado por meio de uma comparação interlaboratorial. O objetivo deste trabalho foi produzir um material de referência (MR quantitativo para EP contendo Bacillus cereus em leite em pó. Uma solução estéril de leite desnatado a 10% contendo 100 mM de sacarose foi contaminada com uma cepa de B. cereus em uma concentração previamente determinada. A matriz foi homogeneizada, distribuída em frascos e liofilizada. O lote produzido foi considerado suficientemente homogêneo atribuindo-se um desvio-padrão alvo de 0,25 log10 UFC/mL. O MR apresentou-se estável a ≤ -70 ºC e (-20 ± 4 ºC durante 1.058 e 60 dias, respectivamente. Na avaliação da influência de diferentes temperaturas para o transporte deste material, o MR se apresentou estável a 4 ºC, 25 ºC e 35 ºC durante o período de quatro dias de estudo. Conclui-se que o lote produzido apresentou todos os requisitos necessários para ser utilizado como itens de EP. ---------------------------------------------------------------------- The participation in proficiency testing (PT is essential for testing laboratories to prove their technical competence. The aim of this study was to produce a quantitative reference material (RM for PT containing Bacillus cereus in milk powder. A sterile solution of 10% skim milk containing 100 mM sucrose was contaminated with a B. cereus strain in a specific concentration. The homogenized matrix was distributed into vials and freeze- -drying. The batch produced was considered sufficiently homogeneous assigning a target standard deviation of 0.25. The RM was stable at ≤ -70 ºC and (-20 ± 4 ºC for 1,058 and 60 days, respectively. In the evaluation of temperatures for the transport of material, the RM was stable at 4, 25 and 35 ºC during four days. It is concluded that the batch produced had all the necessary requirements to be

  3. Electronics engineer's reference book

    CERN Document Server

    Turner, L W

    1976-01-01

    Electronics Engineer's Reference Book, 4th Edition is a reference book for electronic engineers that reviews the knowledge and techniques in electronics engineering and covers topics ranging from basics to materials and components, devices, circuits, measurements, and applications. This edition is comprised of 27 chapters; the first of which presents general information on electronics engineering, including terminology, mathematical equations, mathematical signs and symbols, and Greek alphabet and symbols. Attention then turns to the history of electronics; electromagnetic and nuclear radiatio

  4. New organic reference materials for hydrogen, carbon, and nitrogen stable isotope-ratio measurements: caffeines, n-alkanes, fatty acid methyl esters, glycines, L-valines, polyethylenes, and oils.

    NARCIS (Netherlands)

    Bijma, Anita

    2016-01-01

    An international project developed, quality-tested, and determined isotope–δ values of 19 new organic reference materials (RMs) for hydrogen, carbon, and nitrogen stable isotope-ratio measurements, in addition to analyzing pre-existing RMs NBS 22 (oil), IAEA-CH-7 (polyethylene foil), and IAEA-600 (c

  5. New organic reference materials for hydrogen, carbon, and nitrogen stable isotope-ratio measurements : caffeines, n-alkanes, fatty acid methyl esters, glycines, L-valines, polyethylenes, and oils

    NARCIS (Netherlands)

    Schimmelmann, Arndt; Qi, Haiping; Coplen, Tyler B; Brand, Willi A; Fong, Jon; Meier-Augenstein, Wolfram; Kemp, Helen Felicity; Toman, Blaza; Ackermann, Annika; Assonov, Sergey; Aerts-Bijma, Anita; Brejcha, Ramona; Chikaraishi, Yoshito; Darwish, Tamim A; Elsner, Martin; Gehre, Matthias; Geilmann, Heike; Groening, Manfred; Hélie, Jean-François; Herrero-Martín, Sara; Meijer, Harro A J; Sauer, Peter E; Sessions, Alex Lee; Werner, Roland A

    2016-01-01

    An international project developed, quality-tested, and determined isotope-δ values of 19 new organic reference materials (RMs) for hydrogen, carbon, and nitrogen stable isotope-ratio measurements, in addition to analyzing pre-existing RMs NBS 22 (oil), IAEA-CH-7 (polyethylene foil), and IAEA-600 (c

  6. Integrating Implicit Induction Proofs into Certified Proof Environments

    Science.gov (United States)

    Stratulat, Sorin

    We give evidence of the direct integration and automated checking of implicit induction-based proofs inside certified reasoning environments, as that provided by the Coq proof assistant. This is the first step of a long term project focused on 1) mechanically certifying implicit induction proofs generated by automated provers like Spike, and 2) narrowing the gap between automated and interactive proof techniques inside proof assistants such that multiple induction steps can be executed completely automatically and mutual induction can be treated more conveniently. Contrary to the current approaches of reconstructing implicit induction proofs into scripts based on explicit induction tactics that integrate the usual proof assistants, our checking methodology is simpler and fits better for automation. The underlying implicit induction principles are separated and validated independently from the proof scripts that consist in a bunch of one-to-one translations of implicit induction proof steps. The translated steps can be checked independently, too, so the validation process fits well for parallelisation and for the management of large proof scripts. Moreover, our approach is more general; any kind of implicit induction proof can be considered because the limitations imposed by the proof reconstruction techniques no longer exist. An implementation that integrates automatic translators for generating fully checkable Coq scripts from Spike proofs is reported.

  7. The Effectiveness of "Teach for America" and Other Under-certified Teachers

    Directory of Open Access Journals (Sweden)

    Ildiko Laczko-Kerr

    2002-09-01

    Full Text Available The academic achievements of students taught by under-certified primary school teachers were compared to the academic achievements of students taught by regularly certified primary school teachers.  This sample of under-certified teachers included three types of under-qualified personnel: emergency, temporary and provisionally certified teachers.  One subset of these under-certified teachers was from the national program "Teach For America (TFA."  Recent college graduates are placed by TFA where other under-qualified under-certified teachers are often called upon to work, namely, low-income urban and rural school districts. Certified teachers in this study were from accredited universities and all met state requirements for receiving the regular initial certificate to teach.  Recently hired under-certified and certified teachers (N=293 from five low-income school districts were matched on a number of variables, resulting in 109 pairs of teachers whose students all took the mandated state achievement test. Results indicate 1 that students of TFA teachers did not perform significantly different from students of other under-certified teachers, and 2 that students of certified teachers out-performed students of teachers who were under-certified.  This was true on all three subtests of the SAT 9—reading, mathematics and language arts.  Effect sizes favoring the students of certified teachers were substantial.  In reading, mathematics, and language, the students of certified teachers outperformed students of under-certified teachers, including the students of the TFA teachers, by about 2 months on a grade equivalent scale.  Students of under-certified teachers make about 20% less academic growth per year than do students of teachers with regular certification.  Traditional programs of teacher preparation apparently result in positive effects on the academic achievement of low-income primary school children.  Present

  8. Enhancing the Material Control & Accounting Measurement System at the State Scientific Center of the Russian Federation - Institute for Physics and Power Engineering named after A.I. Leypunsky

    Energy Technology Data Exchange (ETDEWEB)

    Scherer, Carolynn P. [Los Alamos National Laboratory; Bezhunov, Gennady M. [IPPE; Bogdanov, Sergey A. [IPPE; Gorbachev, Vyacheslav M. [IPPE; Ryazanov, Boris G. [IPPE; Talanov, Vladimir V. [IPPE

    2012-07-11

    Nuclear material control and accounting (NMCA) system is improving under cooperation with USA national laboratories. Standard reference materials (RMs) and measurement techniques certified at IPPE level are required for: instrument calibration, verification measurements of parameters of items and materials, measurement error estimation, and quality control measurements. We present the main results for development of nuclear RMs for two uranium strata and the results for certification of three measurement techniques (MT) for U-235 mass fraction in uranium and U-235 mass in items. We present the results for developing measurement techniques for Pu-239 in PuO{sub 2}.

  9. An Amharic Reference Grammar.

    Science.gov (United States)

    Leslau, Wolf

    This reference grammar presents a structural description of the orthography, phonology, morphology, and syntax of Amharic, the national language of Ethiopia. The Amharic material in this work, designed to prepare the student for speaking and reading the language, appears in both Amharic script and phonetic transcription. See ED 012 044-5 for the…

  10. Certified counting of roots of random univariate polynomials

    CERN Document Server

    Cleveland, Joseph; Hauenstein, Jonathan D; Haywood, Ian; Mehta, Dhagash; Morse, Anthony; Robol, Leonardo; Schlenk, Taylor

    2014-01-01

    A challenging problem in computational mathematics is to compute roots of a high-degree univariate random polynomial. We combine an efficient multiprecision implementation for solving high-degree random polynomials with two certification methods, namely Smale's $\\alpha$-theory and one based on Gerschgorin's theorem, for showing that a given numerical approximation is in the quadratic convergence region of Newton's method of some exact solution. With this combination, we can certifiably count the number of real roots of random polynomials. We quantify the difference between the two certification procedures and list the salient features of both of them. After benchmarking on random polynomials where the coefficients are drawn from the Gaussian distribution, we obtain novel experimental results for the Cauchy distribution case.

  11. The Certified Clinical Nurse Leader in Critical Care.

    Science.gov (United States)

    L'Ecuyer, Kristine M; Shatto, Bobbi J; Hoffmann, Rosemary L; Crecelius, Matthew L

    2016-01-01

    Challenges of the current health system in the United States call for collaboration of health care professionals, careful utilization of resources, and greater efficiency of system processes. Innovations to the delivery of care include the introduction of the clinical nurse leader role to provide leadership at the point of care, where it is needed most. Clinical nurse leaders have demonstrated their ability to address needed changes and implement improvements in processes that impact the efficiency and quality of patient care across the continuum and in a variety of settings, including critical care. This article describes the role of the certified clinical nurse leader, their education and skill set, and outlines outcomes that have been realized by their efforts. Specific examples of how clinical nurse leaders impact critical care nursing are discussed.

  12. Core Competencies of the Certified Pediatric Doctor of Chiropractic

    DEFF Research Database (Denmark)

    Hewitt, Elise; Hestbaek, Lise; Pohlman, Katherine A

    2016-01-01

    An outline of the minimum core competencies expected from a certified pediatric doctor of chiropractic was developed using a Delphi consensus process. The initial set of seed statements and substatements was modeled on competency documents used by organizations that oversee chiropractic and medical...... education. These statements were distributed to the Delphi panel, reaching consensus when 80% of the panelists approved each segment. The panel consisted of 23 specialists in chiropractic pediatrics (14 females) from across the broad spectrum of the chiropractic profession. Sixty-one percent of panelists...... had postgraduate pediatric certifications or degrees, 39% had additional graduate degrees, and 74% were faculty at a chiropractic institution and/or in a postgraduate pediatrics program. The panel were initially given 10 statements with related substatements formulated by the study's steering...

  13. A Quantum Random Number Generator Certified by Value Indefiniteness

    CERN Document Server

    Abbott, Alastair A; Svozil, Karl

    2010-01-01

    In this paper we propose a quantum random number generator (QRNG) which utilizes an entangled photon pair in a Bell singlet state, and is certified explicitly by value indefiniteness. While "true randomness" is a mathematical impossibility, the certification by value indefiniteness ensures the quantum random bits are incomputable in the strongest sense. This is the first QRNG setup in which a physical principle (Kochen-Specker value indefiniteness) guarantees that no single quantum bit produced can be classically computed (reproduced and validated), the mathematical form of bitwise physical unpredictability. The effects of various experimental imperfections are discussed in detail, particularly those related to detector efficiencies, context alignment and temporal correlations between bits. The analysis is to a large extent relevant for the construction of any QRNG based on beam-splitters. By measuring the two entangled photons in maximally misaligned contexts and utilizing the fact that two rather than one b...

  14. Development of a low-level radon reference atmosphere.

    Science.gov (United States)

    Linzmaier, Diana; Röttger, Annette

    2013-11-01

    In order to calibrate measurement devices for the activity concentration of Rn-222 (radon) in air below 1,000 Bq/m(3), a constant for long time (>5d), homogeneous reference atmosphere is created by a certified activity in a certified volume. The PTB developed this reference atmosphere from 150 Bq/m(3) to 2,000 Bq/m(3) based on the precisely known emanation of Rn-222 from a Ra-226 activity standard. This set-up reduces uncertainties and increases the range of traceability for commercial radon measurement devices. Thus, a gap in radon metrology is closed. The new primary standard for reference atmospheres is realised with a combined relative standard uncertainty of 1.1%.

  15. Austenitic chromium nickel steel as standard reference material in measurement of thermal and temperature conductivity. [X10 NiCrMoTiB 15 15]. Austenitischer Chromnickelstahl als Standardreferenzmaterial bei Messungen der Waerme- und Temperaturleitfaehigkeit

    Energy Technology Data Exchange (ETDEWEB)

    Binkele, L.

    1990-01-01

    A niobium-stabilized CrNi steel with the NBS designation SRM 735 is introduced as WLF standard reference material in a report by Hust and Giarratano, for the temperature range 300-1200 K and for thermal conductivities around 20 W/mk. However, its specification does not show it to be a direct member of the DIN family of CrNi steels. This report should be regarded as a continuation and supplement to the above-mentioned efforts in America. On the one hand, a solution of a possibly too-narrow specification is aimed at for the reference material, where it is important how sensitive the thermal conductivity is to changes in the chemical composition and changes of the manufacturing parameters and what accuracy can be reached for the reference values with the best measurement techniques. On the other hand, the data base should be expanded and the accuracy of the reference curve should be improved if possible. (orig./MM).

  16. Digestion of plastic materials for the determination of toxic metals with a microwave oven for household use.

    Science.gov (United States)

    Sakurai, Hiroki; Noro, Junji; Kawase, Akira; Fujinami, Masanori; Oguma, Koichi

    2006-02-01

    A rapid sample-digestion method for the determination of toxic metals, cadmium, chromium, and lead, in polyethylene and polyvinyl chloride has been developed by using a microwave oven for household use. An appropriate amount of the sample taken in a PTFE decomposition vessel was mixed with nitric acid or nitric and sulfuric acids. The vessel was heated in a microwave oven by a predetermined operating program. The digested sample was diluted to a definite volume with water after evaporating most of the nitric acid. The precipitate, if formed, was filtered off by a membrane filter. The metals were determined by ICP-AES. The sample digestion required 5 min (for 20-mg sample) to 25 min (for 60-mg sample). The analytical results obtained for cadmium, chromium, and lead in a polyethylene certified reference material, BCR-680, digested with nitric acid, were in good agreement with the certified values.

  17. On the isolation of elemental carbon for micro-molar 14C accelerator mass spectrometry; evaluation of alternative isolation procedures, and accuracy assurance using a hybrid isotopic particulate carbon reference material

    OpenAIRE

    Currie, L A; Kessler,J.D.

    2005-01-01

    International audience; The primary objective of the research reported here has been the development of an hybrid reference material (RM) to serve as a test of accuracy for elemental carbon (EC) isotopic (14C) speciation measurements. Such measurements are critically important for the quantitative apportionment of fossil and biomass sources of ''soot'' (EC), the tracer of fire that has profound effects on health, atmospheric visibility, and climate. Previous studies of 14C-EC measurement qual...

  18. Chinese Language Teachers Should Utilize Teaching Reference Materials%语文教师要活用教学参考资料

    Institute of Scientific and Technical Information of China (English)

    黄文轩

    2014-01-01

    学校里,很多语文教师把教参奉若经典,创造性思维因此受到了影响。笔者认为,教师备课过程中应该多一些独立思考,少做些“搬运”的工作,应走创造性使用教参的道路,让思想灵动起来,让语文教学鲜活起来。%In school, many language teachers take teaching reference as classic, creative thinking and therefore affected. Per-sonally believe that teacher preparation process should be more independent thinking, do less"handling"work, the creative use of teaching reference should go on the road, so thinking up clever, so make language teaching alive.

  19. Development of Paeonol Purity Reference Material and Method of Valuation%丹皮酚化学纯度标准物质研制与定值分析方法研究

    Institute of Scientific and Technical Information of China (English)

    徐维盛; 杨德智; 张丽; 杨宁; 马辰; 吕扬

    2011-01-01

    Objective To develop the paeonol purity reference material which has measurement traceability and high accuracy, and establish an effective method of valuation. Methods The paeonol purity reference material was studied on the basis of National Standard Material technical specification requirements. The homogeneity and stability test were measured by HPLC. The purity and uncertainty evaluation of the substance was measured by the peak area normalization method of HPLC and coulometry method. Results The paeonol purity reference material developed in this study conforms to the technical requirements of national primary standard reference material. The purity value and uncertainty evaluation of paeonol was (99. 87 ± 0.35)% (k = 2, P= 0.95). Conclusion The method established in our study was proved to be rapid, accurate and reliable, and was successfully applied to the purity value and uncertainty evaluation of paeonol purity reference material. It can provide the characteristic value transfer function.%目的 研制我国具有可溯源性高准确度量值的丹皮酚化学纯度标准物质,并建立有效定值分析方法 .方法 依据我国一级标准物质研制技术规范与有关技术文件,制备丹皮酚化学纯度标准物质,采用高效液相色谱(HPLC)法进行均匀性检验与稳定性考察;采用高效液相色谱技术面积归一化法与溴库伦滴定法对丹皮酚化学纯度标准物质联合定值.结果 研制的丹皮酚化学纯度标准物质符合我国有证标准物质要求,标准值与不确定度评估值为(99.87±0.35)%(k=2,P=0.95).结论 该实验研制的丹皮酚化学纯度标准物质与建立的联合定值方法 可实现对其化学纯度的定值与不确定度评估,方法 具有快速、准确的特点,提供了量值传递功能.

  20. Characterization of 107 genomic DNA reference materials for CYP2D6, CYP2C19, CYP2C9, VKORC1, and UGT1A1: a GeT-RM and Association for Molecular Pathology collaborative project.

    Science.gov (United States)

    Pratt, Victoria M; Zehnbauer, Barbara; Wilson, Jean Amos; Baak, Ruth; Babic, Nikolina; Bettinotti, Maria; Buller, Arlene; Butz, Ken; Campbell, Matthew; Civalier, Chris; El-Badry, Abdalla; Farkas, Daniel H; Lyon, Elaine; Mandal, Saptarshi; McKinney, Jason; Muralidharan, Kasinathan; Noll, LeAnne; Sander, Tara; Shabbeer, Junaid; Smith, Chingying; Telatar, Milhan; Toji, Lorraine; Vairavan, Anand; Vance, Carlos; Weck, Karen E; Wu, Alan H B; Yeo, Kiang-Teck J; Zeller, Markus; Kalman, Lisa

    2010-11-01

    Pharmacogenetic testing is becoming more common; however, very few quality control and other reference materials that cover alleles commonly included in such assays are currently available. To address these needs, the Centers for Disease Control and Prevention's Genetic Testing Reference Material Coordination Program, in collaboration with members of the pharmacogenetic testing community and the Coriell Cell Repositories, have characterized a panel of 107 genomic DNA reference materials for five loci (CYP2D6, CYP2C19, CYP2C9, VKORC1, and UGT1A1) that are commonly included in pharmacogenetic testing panels and proficiency testing surveys. Genomic DNA from publicly available cell lines was sent to volunteer laboratories for genotyping. Each sample was tested in three to six laboratories using a variety of commercially available or laboratory-developed platforms. The results were consistent among laboratories, with differences in allele assignments largely related to the manufacturer's assay design and variable nomenclature, especially for CYP2D6. The alleles included in the assay platforms varied, but most were identified in the set of 107 DNA samples. Nine additional pharmacogenetic loci (CYP4F2, EPHX1, ABCB1, HLAB, KIF6, CYP3A4, CYP3A5, TPMT, and DPD) were also tested. These samples are publicly available from Coriell and will be useful for quality assurance, proficiency testing, test development, and research.

  1. 7 CFR 982.455 - Exchange of certified merchantable hazelnuts withheld.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Exchange of certified merchantable hazelnuts withheld... AGRICULTURE HAZELNUTS GROWN IN OREGON AND WASHINGTON Administrative Rules and Regulations § 982.455 Exchange of certified merchantable hazelnuts withheld. Each handler desiring to exchange hazelnuts pursuant...

  2. 7 CFR 982.55 - Exchange of certified merchantable hazelnuts withheld.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Exchange of certified merchantable hazelnuts withheld... AGRICULTURE HAZELNUTS GROWN IN OREGON AND WASHINGTON Order Regulating Handling Control of Distribution § 982.55 Exchange of certified merchantable hazelnuts withheld. Any handler who has withheld from...

  3. 12 CFR 564.3 - Appraisals required; transactions requiring a State certified or licensed appraiser.

    Science.gov (United States)

    2010-01-01

    ... SUPERVISION, DEPARTMENT OF THE TREASURY APPRAISALS § 564.3 Appraisals required; transactions requiring a State certified or licensed appraiser. (a) Appraisals required. An appraisal performed by a State certified or..., pooled loan, or real property interest met OTS regulatory requirements for appraisals at the time...

  4. 12 CFR 34.43 - Appraisals required; transactions requiring a State certified or licensed appraiser.

    Science.gov (United States)

    2010-01-01

    ..., DEPARTMENT OF THE TREASURY REAL ESTATE LENDING AND APPRAISALS Appraisals § 34.43 Appraisals required; transactions requiring a State certified or licensed appraiser. (a) Appraisals required. An appraisal performed by a State certified or licensed appraiser is required for all real estate-related...

  5. 12 CFR 225.63 - Appraisals required; transactions requiring a State certified or licensed appraiser.

    Science.gov (United States)

    2010-01-01

    ... Appraisals required; transactions requiring a State certified or licensed appraiser. (a) Appraisals required. An appraisal performed by a State certified or licensed appraiser is required for all real estate... or United States government sponsored agency; or (ii) Involves a residential real estate...

  6. 48 CFR 52.215-12 - Subcontractor Certified Cost or Pricing Data.

    Science.gov (United States)

    2010-10-01

    ... Cost or Pricing Data. 52.215-12 Section 52.215-12 Federal Acquisition Regulations System FEDERAL... Provisions and Clauses 52.215-12 Subcontractor Certified Cost or Pricing Data. As prescribed in 15.408(d), insert the following clause: Subcontractor Certified Cost or Pricing Data (OCT 2010) (a) Before...

  7. 48 CFR 15.403-3 - Requiring data other than certified cost or pricing data.

    Science.gov (United States)

    2010-10-01

    ... certified cost or pricing data. 15.403-3 Section 15.403-3 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACTING METHODS AND CONTRACT TYPES CONTRACTING BY NEGOTIATION Contract Pricing 15.403-3 Requiring data other than certified cost or pricing data. (a)(1) In those acquisitions that...

  8. 48 CFR 428.204-2 - Certified or cashier's checks, bank drafts, money orders, or currency.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Certified or cashier's checks, bank drafts, money orders, or currency. 428.204-2 Section 428.204-2 Federal Acquisition... Other Security for Bonds 428.204-2 Certified or cashier's checks, bank drafts, money orders, or...

  9. 30 CFR Appendix to Subpart B - Optional Form for Certifying Mine Rescue Teams

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Optional Form for Certifying Mine Rescue Teams... EDUCATION AND TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines Pt. 49, Subpt. B, App. Appendix to Subpart B—Optional Form for Certifying Mine Rescue Teams ER08FE08.000 ER08FE08.001...

  10. 13 CFR 121.805 - May a business concern self-certify its size status?

    Science.gov (United States)

    2010-01-01

    ...-certify its size status? 121.805 Section 121.805 Business Credit and Assistance SMALL BUSINESS... Requirements for Paying Reduced Patent Fees § 121.805 May a business concern self-certify its size status? (a) A concern verifies its size status with its submission of its patent application. (b) Any attempt...

  11. 19 CFR 115.16 - Notification of Certifying Authority by manufacturer.

    Science.gov (United States)

    2010-04-01

    ... manufacturer. 115.16 Section 115.16 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND... INTERNATIONAL CUSTOMS CONVENTIONS Administration § 115.16 Notification of Certifying Authority by manufacturer. In order that the Certifying Authority can schedule an appropriate inspection, a manufacturer...

  12. Recognising and Certifying Lifelong Skills: Impact on Labour Market Integration of the Unemployed

    Science.gov (United States)

    Fernandes, Pedro Afonso

    2009-01-01

    The process for recognising, validating and certifying (RVC) non-formally or informally acquired lifelong learning, launched in 2000, is now part of mainstream education and training policies in Portugal. This article aims to determine how much the labour-market behaviour of the RVC-certified unemployed differs from that of other unemployed…

  13. 40 CFR 91.1013 - Exemption for certified Small SI engines.

    Science.gov (United States)

    2010-07-01

    ... Marine SI Engines § 91.1013 Exemption for certified Small SI engines. The provisions of 40 CFR 1045.605... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Exemption for certified Small SI engines. 91.1013 Section 91.1013 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)...

  14. The Value-Added Achievement Gains of NBPTS-Certified Teachers in Tennessee: A Brief Report.

    Science.gov (United States)

    Stone, J. E.

    This study investigated whether National Board for Professional Teaching Standards (NBPTS)-certified teachers in Tennessee were exceptionally effective in bringing about objectively measured student achievement gains. Tennessee has over 40 NBPTS-certified teachers, 16 of whom teach in grades 3-8 and have value-added teacher reports in the state…

  15. 19 CFR 10.57 - Certified seed potatoes, and seed corn or maize.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Certified seed potatoes, and seed corn or maize... Provisions Potatoes, Corn, Or Maize § 10.57 Certified seed potatoes, and seed corn or maize. Claim for classification as seed potatoes under subheading 0701.10.00, as seed corn (maize) under subheading...

  16. 7 CFR 201.73 - Processors and processing of all classes of certified seed.

    Science.gov (United States)

    2010-01-01

    ... seed. 201.73 Section 201.73 Agriculture Regulations of the Department of Agriculture (Continued... (CONTINUED) FEDERAL SEED ACT FEDERAL SEED ACT REGULATIONS Certified Seed § 201.73 Processors and processing of all classes of certified seed. The following requirements must be met by processors of all...

  17. 20 CFR 416.804 - Certified copy in lieu of original.

    Science.gov (United States)

    2010-04-01

    ... AGED, BLIND, AND DISABLED Determination of Age § 416.804 Certified copy in lieu of original. In lieu of the original of any record, except a Bible or other family record, there may be submitted as evidence... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Certified copy in lieu of original....

  18. 17 CFR 274.128 - Form N-CSR, certified shareholder report.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Form N-CSR, certified... Form N-CSR, certified shareholder report. This form shall be used by registered management investment... of this chapter. Editorial Note: For Federal Register citations affecting Form N-CSR, see the List...

  19. Understanding Georgia's National Board Certified Teachers: A Phenomenological Approach to a Teacher's Perspective

    Science.gov (United States)

    Brantley, Kimberly K.

    2014-01-01

    The purpose of this phenomenological study was to understand what it means to be a National Board Certified teacher (NBCT) in Georgia. Georgia teachers, distinguished with the NBCT title, participated in surveys and interviews which were analyzed qualitatively in order to understand the essence of being a National Board Certified teacher. Three…

  20. 7 CFR 301.75-17 - Funds for the replacement of certified citrus nursery stock.

    Science.gov (United States)

    2010-01-01

    ...) ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE DOMESTIC QUARANTINE NOTICES Citrus Canker Notice of Quarantine and Regulations § 301.75-17 Funds for the replacement of certified citrus... 7 Agriculture 5 2010-01-01 2010-01-01 false Funds for the replacement of certified citrus...

  1. Why Do National Board Certified Teachers from Generation X Leave the Classroom?

    Science.gov (United States)

    Crain, Julie Christi

    2013-01-01

    This qualitative multiple case study focused on National Board Certified teachers from Generation X who have left the classroom. The study explored aspects of the teaching profession, the National Board Certification process, and Generation X as potential influences for National Board Certified teachers from Generation X to leave the classroom.…

  2. 30 CFR 18.80 - Approval of machines assembled with certified or explosion-proof components.

    Science.gov (United States)

    2010-07-01

    ... or explosion-proof components. 18.80 Section 18.80 Mineral Resources MINE SAFETY AND HEALTH... MINE EQUIPMENT AND ACCESSORIES Machines Assembled With Certified or Explosion-Proof Components, Field... assembled with certified or explosion-proof components. (a) A machine may be a new assembly, or a...

  3. Characterisation of Leather Candidate Certified Reference Materials for their Mass Fractions of Aromatic Amines%用于分析皮革样本中芳香胺质量含量的检定标准物质的表征

    Institute of Scientific and Technical Information of China (English)

    Jan-Willem Wegener; Haiko Schulz; 龚英

    2011-01-01

    Three batches of leather samples were colored with nine aso dyes that can yield eight proven or suspected carcinogenic aromatic amines under reduction conditions. The samples were milled to grains and bottled in jars. A group of five laboratories has established the mass fraction of the amines in a ring test using different analytical methods. The methods included a reduction step in order to cleave the azo dyes into the aromatic amines. Quantification was by standard addition: sub - samples of the leathers were spiked with known amounts of azo dyes of known purity. It was possible to establish the mass fractions of six of the eight aromatic amines in three of the leather samples.%用9种已经确认或被怀疑的在还原条件下将生成8种致癌芳香胺的染料,对3批皮革样品染色.将皮革样品切碎为颗粒后,装入到广口瓶中.由5个实验室组成的试验组,在环试验中采用不同方法分析这些芳香胺在皮革中所占的质量分数.这些分析方法均包括还原步骤,即,使偶氮染料裂解为芳香胺.采用向皮革子样本加入已知量的且已知纯度的偶氮染料这种标准加入法,进行定量分析.在这3批皮革样品中,可以对这8类芳香胺中的6种进行质量含量的分析.

  4. A new large-volume metal reference standard for radioactive waste management.

    Science.gov (United States)

    Tzika, F; Hult, M; Stroh, H; Marissens, G; Arnold, D; Burda, O; Kovář, P; Suran, J; Listkowska, A; Tyminski, Z

    2016-03-01

    A new large-volume metal reference standard has been developed. The intended use is for calibration of free-release radioactivity measurement systems and is made up of cast iron tubes placed inside a box of the size of a Euro-pallet (80 × 120 cm). The tubes contain certified activity concentrations of (60)Co (0.290 ± 0.006 Bq g(-1)) and (110m)Ag (3.05 ± 0.09 Bq g(-1)) (reference date: 30 September 2013). They were produced using centrifugal casting from a smelt into which (60)Co was first added and then one piece of neutron irradiated silver wire was progressively diluted. The iron castings were machined to the desirable dimensions. The final material consists of 12 iron tubes of 20 cm outer diameter, 17.6 cm inner diameter, 40 cm length/height and 245.9 kg total mass. This paper describes the reference standard and the process of determining the reference activity values.

  5. Materials

    Science.gov (United States)

    Glaessgen, Edward H.; Schoeppner, Gregory A.

    2006-01-01

    NASA Langley Research Center has successfully developed an electron beam freeform fabrication (EBF3) process, a rapid metal deposition process that works efficiently with a variety of weldable alloys. The EBF3 process can be used to build a complex, unitized part in a layer-additive fashion, although the more immediate payoff is for use as a manufacturing process for adding details to components fabricated from simplified castings and forgings or plate products. The EBF3 process produces structural metallic parts with strengths comparable to that of wrought product forms and has been demonstrated on aluminum, titanium, and nickel-based alloys to date. The EBF3 process introduces metal wire feedstock into a molten pool that is created and sustained using a focused electron beam in a vacuum environment. Operation in a vacuum ensures a clean process environment and eliminates the need for a consumable shield gas. Advanced metal manufacturing methods such as EBF3 are being explored for fabrication and repair of aerospace structures, offering potential for improvements in cost, weight, and performance to enhance mission success for aircraft, launch vehicles, and spacecraft. Near-term applications of the EBF3 process are most likely to be implemented for cost reduction and lead time reduction through addition of details onto simplified preforms (casting or forging). This is particularly attractive for components with protruding details that would require a significantly large volume of material to be machined away from an oversized forging, offering significant reductions to the buy-to-fly ratio. Future far-term applications promise improved structural efficiency through reduced weight and improved performance by exploiting the layer-additive nature of the EBF3 process to fabricate tailored unitized structures with functionally graded microstructures and compositions.

  6. Automated extraction of DNA from reference samples from various types of biological materials on the Qiagen BioRobot EZ1 Workstation

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Jørgensen, Mads; Hansen, Anders Johannes

    2009-01-01

    We have validated and implemented a protocol for DNA extraction from various types of biological materials using a Qiagen BioRobot EZ1 Workstation. The sample materials included whole blood, blood from deceased, buccal cells on Omni swabs and FTA Cards, blood on FTA Cards and cotton swabs......, and muscle biopsies. The DNA extraction was validated according to EN/ISO 17025 for the STR kits AmpFlSTR« Identifiler« and AmpFlSTR« Yfiler« (Applied Biosystems). Of 298 samples extracted, 11 (4%) did not yield acceptable results. In conclusion, we have demonstrated that extraction of DNA from various types...... of biological material can be performed quickly and without the use of hazardous chemicals, and that the DNA may be successfully STR typed according to the requirements of forensic genetic investigations accredited according to EN/ISO 17025...

  7. Enterprise Reference Library

    Science.gov (United States)

    Bickham, Grandin; Saile, Lynn; Havelka, Jacque; Fitts, Mary

    2011-01-01

    Introduction: Johnson Space Center (JSC) offers two extensive libraries that contain journals, research literature and electronic resources. Searching capabilities are available to those individuals residing onsite or through a librarian s search. Many individuals have rich collections of references, but no mechanisms to share reference libraries across researchers, projects, or directorates exist. Likewise, information regarding which references are provided to which individuals is not available, resulting in duplicate requests, redundant labor costs and associated copying fees. In addition, this tends to limit collaboration between colleagues and promotes the establishment of individual, unshared silos of information The Integrated Medical Model (IMM) team has utilized a centralized reference management tool during the development, test, and operational phases of this project. The Enterprise Reference Library project expands the capabilities developed for IMM to address the above issues and enhance collaboration across JSC. Method: After significant market analysis for a multi-user reference management tool, no available commercial tool was found to meet this need, so a software program was built around a commercial tool, Reference Manager 12 by The Thomson Corporation. A use case approach guided the requirements development phase. The premise of the design is that individuals use their own reference management software and export to SharePoint when their library is incorporated into the Enterprise Reference Library. This results in a searchable user-specific library application. An accompanying share folder will warehouse the electronic full-text articles, which allows the global user community to access full -text articles. Discussion: An enterprise reference library solution can provide a multidisciplinary collection of full text articles. This approach improves efficiency in obtaining and storing reference material while greatly reducing labor, purchasing and

  8. OSH technical reference manual

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-01

    In an evaluation of the Department of Energy (DOE) Occupational Safety and Health programs for government-owned contractor-operated (GOCO) activities, the Department of Labor`s Occupational Safety and Health Administration (OSHA) recommended a technical information exchange program. The intent was to share written safety and health programs, plans, training manuals, and materials within the entire DOE community. The OSH Technical Reference (OTR) helps support the secretary`s response to the OSHA finding by providing a one-stop resource and referral for technical information that relates to safe operations and practice. It also serves as a technical information exchange tool to reference DOE-wide materials pertinent to specific safety topics and, with some modification, as a training aid. The OTR bridges the gap between general safety documents and very specific requirements documents. It is tailored to the DOE community and incorporates DOE field experience.

  9. Do LEED-certified buildings save energy? Not really...

    Energy Technology Data Exchange (ETDEWEB)

    Scofield, John H. [Department of Physics and Astronomy, Oberlin College, Oberlin, OH (United States)

    2009-12-15

    Newsham et al. have recently published a re-analysis of energy-consumption data for LEED-certified commercial buildings supplied by the New Buildings Institute (NBI) and US Green Building Council. They find that, on average, LEED buildings use 18-39% less energy per floor area than their conventional counterparts, consistent with and adding clarity to conclusions originally reached by NBI. These conclusions, however, hang on a particular definition of the mean energy intensity of a collection of buildings that is not related to the total energy used by those buildings. Furthermore, site energy considered by Newsham et al. and NBI, unlike source energy used for the EPA's building Energy Star rating, does not account for the energy consumed off-site in generating and delivering electric energy to the building, whose inclusion is crucial for understanding greenhouse gas emission associated with building operation. Here I demonstrate that both the site energy and source energy used by the set of 35 LEED office buildings and Newsham et al.'s matching CBECS office buildings are statistically equivalent. Hence Newsham et al. offer no evidence that LEED-certification has collectively lowered either site or source energy for office buildings. (author)

  10. Do LEED-certified buildings save energy? Yes, but...

    Energy Technology Data Exchange (ETDEWEB)

    Newsham, Guy R.; Mancini, Sandra; Birt, Benjamin J. [National Research Council Canada - Institute for Research in Construction, Ottawa (Canada)

    2009-08-15

    We conducted a re-analysis of data supplied by the New Buildings Institute and the US Green Buildings Council on measured energy use data from 100 LEED-certified commercial and institutional buildings. These data were compared to the energy use of the general US commercial building stock. We also examined energy use by LEED certification level, and by energy-related credits achieved in the certification process. On average, LEED buildings used 18-39% less energy per floor area than their conventional counterparts. However, 28-35% of LEED buildings used more energy than their conventional counterparts. Further, the measured energy performance of LEED buildings had little correlation with certification level of the building, or the number of energy credits achieved by the building at design time. Therefore, at a societal level, green buildings can contribute substantial energy savings, but further work needs to be done to define green building rating schemes to ensure more consistent success at the individual building level. Note, these findings should be considered as preliminary, and the analyses should be repeated when longer data histories from a larger sample of green buildings are available. (author)

  11. Injuries in the Iowa Certified Safe Farm Study.

    Science.gov (United States)

    Rautiainen, R H; Lange, J L; Hodne, C J; Schneiders, S; Donham, K J

    2004-01-01

    The aims of this article are to assess injury characteristics and risk factors in the Iowa Certified Safe Farm (CSF) program and to evaluate the effectiveness of CSF for reducing injuries. This intervention program includes a health screening, on-farm safety review, education, and monetary incentives. Cohorts of farmers in an intervention group (n = 152) and control group (n = 164) in northwestern Iowa were followed for a three-year period. During the follow-up, there were 318 injuries (42/100 person-years), of which 112 (15/100 person-years) required professional medical care. The monetary cost of injuries was $51,764 ($68 per farm per year). There were no differences in the self-reported injury rates and costs between the intervention and control groups. Raising livestock, poor general health, and exposures to dust and gas, noise, chemicals and pesticides, and lifting were among risk factors for injury. Most injuries in this study were related to animals, falls from elevation, slips/trips/falls, being struck by or struck against objects, lifting, and overexertion. Machinery was less prominent than generally reported in the literature. Hurry, fatigue, or stress were mentioned as the primary contributing factor in most injuries. These findings illustrate the need for new interventions to address a multitude of hazards in the farm work environment as well as management and organization of farm work.

  12. Science inquiry learning environments created by National Board Certified Teachers

    Science.gov (United States)

    Saderholm, Jon

    The purpose of this study was to discern what differences exist between the science inquiry learning environments created by National Board Certified Teachers (NBCTs) and non-NBCTs. Four research questions organized the data collection and analysis: (a) How do National Board Certified science teachers' knowledge of the nature of science differ from that of their non-NBCT counterparts? (b) How do the frequencies of student science inquiry behaviors supported by in middle/secondary learning environments created by NBCTs differ from those created by their non-NBCT counterparts? (c) What is the relationship between the frequency of students' science inquiry behaviors and their science reasoning and understanding of the nature of science? (d) What is the impact of teacher perceptions factors impacting curriculum and limiting inquiry on the existence of inquiry learning environments? The setting in which this study was conducted was middle and high schools in Kentucky during the period between October 2006 and January 2007. The population sampled for the study was middle and secondary science teachers certified to teach in Kentucky. Of importance among those were the approximately 70 National Board Certified middle and high school science teachers. The teacher sample consisted of 50 teachers, of whom 19 were NBCTs and 31 were non-NBCTs. This study compared the science inquiry teaching environments created by NBCTs and non-NBCTs along with their consequent effect on the science reasoning and nature of science (NOS) understanding of their students. In addition, it examined the relationship with these science inquiry environments of other teacher characteristics along with teacher perception of factors influencing curriculum and factors limiting inquiry. This study used a multi-level mixed methodology study incorporating both quantitative and qualitative measures of both teachers and their students. It was a quasi-experimental design using non-random assignment of

  13. Towards a Certified Lightweight Array Bound Checker for Java Bytecode

    Science.gov (United States)

    Pichardie, David

    2009-01-01

    Dynamic array bound checks are crucial elements for the security of a Java Virtual Machines. These dynamic checks are however expensive and several static analysis techniques have been proposed to eliminate explicit bounds checks. Such analyses require advanced numerical and symbolic manipulations that 1) penalize bytecode loading or dynamic compilation, 2) complexify the trusted computing base. Following the Foundational Proof Carrying Code methodology, our goal is to provide a lightweight bytecode verifier for eliminating array bound checks that is both efficient and trustable. In this work, we define a generic relational program analysis for an imperative, stackoriented byte code language with procedures, arrays and global variables and instantiate it with a relational abstract domain as polyhedra. The analysis has automatic inference of loop invariants and method pre-/post-conditions, and efficient checking of analysis results by a simple checker. Invariants, which can be large, can be specialized for proving a safety policy using an automatic pruning technique which reduces their size. The result of the analysis can be checked efficiently by annotating the program with parts of the invariant together with certificates of polyhedral inclusions. The resulting checker is sufficiently simple to be entirely certified within the Coq proof assistant for a simple fragment of the Java bytecode language. During the talk, we will also report on our ongoing effort to scale this approach for the full sequential JVM.

  14. Certified safe farm: identifying and removing hazards on the farm.

    Science.gov (United States)

    Rautiainen, R H; Grafft, L J; Kline, A K; Madsen, M D; Lange, J L; Donham, K J

    2010-04-01

    This article describes the development of the Certified Safe Farm (CSF) on-farm safety review tools, characterizes the safety improvements among participating farms during the study period, and evaluates differences in background variables between low and high scoring farms. Average farm review scores on 185 study farms improved from 82 to 96 during the five-year study (0-100 scale, 85 required for CSF certification). A total of 1292 safety improvements were reported at an estimated cost of $650 per farm. A wide range of improvements were made, including adding 9 rollover protective structures (ROPS), 59 power take-off (PTO) master shields, and 207 slow-moving vehicle (SMV) emblems; improving lighting on 72 machines: placing 171 warning decals on machinery; shielding 77 moving parts; locking up 17 chemical storage areas, adding 83 lockout/tagout improvements; and making general housekeeping upgrades in 62 farm buildings. The local, trained farm reviewers and the CSF review process overall were well received by participating farmers. In addition to our earlier findings where higher farm review scores were associated with lower self-reported health outcome costs, we found that those with higher farm work hours, younger age, pork production in confinement, beef production, poultry production, and reported exposure to agrichemicals had higher farm review scores than those who did not have these characteristics. Overall, the farm review process functioned as expected. encouraging physical improvements in the farm environment, and contributing to the multi-faceted CSF intervention program.

  15. Methodology for the characterization and radioactive tracing of a reference to the control of radioactive material in steel mills; Metodologia para la caracterizacion y trazado radiactivo de un material de referencia para el control radiactivo en acerias

    Energy Technology Data Exchange (ETDEWEB)

    Mejuto Mendieta, M.; Crespo Vazquez, M. T.; Peyres Medina, V.; Garcia-Torano, E.; Perez del Villar, L.

    2013-07-01

    One of the tasks which corresponded you to the Laboratory of Metrology of Ionizing Radiation CIEMAT, consists of the preparation of the reference standards of a black slag from steel making drawn {sup 2}26Ra, {sup 1}37Cs, {sup 6}0Co. This work summarizes the steps followed for the preparation of the reference standards of the slag, including the physical sample preparation, chemical, mineralogical and radioactive characterization as well as the development of the method of path with the above listed radionuclides. (Author)

  16. Current state of laser synthesis of metal and alloy nanoparticles as ligand-free reference materials for nano-toxicological assays

    Directory of Open Access Journals (Sweden)

    Christoph Rehbock

    2014-09-01

    Full Text Available Due to the abundance of nanomaterials in medical devices and everyday products, toxicological effects related to nanoparticles released from these materials, e.g., by mechanical wear, are a growing matter of concern. Unfortunately, appropriate nanoparticles required for systematic toxicological evaluation of these materials are still lacking. Here, the ubiquitous presence of surface ligands, remaining from chemical synthesis are a major drawback as these organic residues may cause cross-contaminations in toxicological studies. Nanoparticles synthesized by pulsed laser ablation in liquid are a promising alternative as this synthesis route provides totally ligand-free nanoparticles. The first part of this article reviews recent methods that allow the size control of laser-fabricated nanoparticles, focusing on laser post irradiation, delayed bioconjugation and in situ size quenching by low salinity electrolytes. Subsequent or parallel applications of these methods enable precise tuning of the particle diameters in a regime from 4–400 nm without utilization of any artificial surface ligands. The second paragraph of this article highlights the recent progress concerning the synthesis of composition controlled alloy nanoparticles by laser ablation in liquids. Here, binary and ternary alloy nanoparticles with totally homogeneous elemental distribution could be fabricated and the composition of these particles closely resembled bulk implant material. Finally, the model AuAg was used to systematically evaluate composition related toxicological effects of alloy nanoparticles. Here Ag+ ion release is identified as the most probable mechanism of toxicity when recent toxicological studies with gametes, mammalian cells and bacteria are considered.

  17. [Survey on the attitude toward genetic testing of neurologists certified by the Japanese Society of Neurology].

    Science.gov (United States)

    Yoshida, Kunihiro; Ohata, Takako; Muto, Kaori; Tsuchiya, Atsushi; Sawada, Jinichi; Hazama, Takanori; Ikeda, Shu-Ichi; Toda, Tatsushi

    2013-01-01

    To clarify the attitude toward genetic testing for neuromuscular diseases, a questionnaire was sent to 4,762 neurologists certified by the Japanese Society of Neurology. By December 21, 2011, 1,493 questionnaires (31.4%) were returned. Of these, 1,233 (82.6%) had experienced genetic testing, but only 396 (26.5%) had referred to the guideline for genetic testing of the Japanese Society of Neurology (2009). The numbers of respondents who were positive, or more positive than negative for genetic testing for myotonic dystrophy type 1 (DM1), Huntington's disease (HD), and familial amyloid polyneuropathy (FAP) were 753 (50.4%), 915 (61.3%), and 980 (65.6%), respectively. The predominant reason for a positive attitude toward genetic testing was to confirm or exclude the diagnosis. Conversely, the predominant reason for a negative attitude toward genetic testing differed between the diseases. For DM1, it was to confirm the diagnosis without genetic testing. For HD, it was that genetic testing would not result in effective prevention or therapy. In FAP, it was that post-testing psychosocial support for the patient and their family was difficult. Common to DM1, HD, and FAP, a significant number of respondents (approximately 60%) felt it difficult to explain the negative aspects that might occur after the disclosure of test results. Concerning predictive or prenatal genetic testing, most respondents referred at-risk individuals to specialized genetic counseling clinics. In general, neurologists are likely to conduct genetic testing properly in consideration not only of the characteristics of the diseases but also of the circumstances of each patient and his or her family. To support neurologists who are involved in genetic testing, the guidelines should be more easily accessible. Many respondents wanted information on the institutions that provide genetic counseling and testing; however, financial support to such institutions is indispensable for fulfilling this requirement.

  18. 40 CFR 1045.610 - What provisions apply to using engines already certified to Small SI emission standards?

    Science.gov (United States)

    2010-07-01

    ... already certified to Small SI emission standards? 1045.610 Section 1045.610 Protection of Environment... engines already certified to Small SI emission standards? This section applies to marine engines that are identical to land-based engines certified under 40 CFR part 90 or 1054. See § 1045.605 for provisions...

  19. 48 CFR 52.215-11 - Price Reduction for Defective Certified Cost or Pricing Data-Modifications.

    Science.gov (United States)

    2010-10-01

    ... subcontractor furnished certified cost or pricing data that were not complete, accurate, and current as certified in its Certificate of Current Cost or Pricing Data, (2) a subcontractor or prospective... current as certified in the Contractor's Certificate of Current Cost or Pricing Data, or (3) any of...

  20. Presentation of a reference material for the spatially resolved hydrogen analytics in near-surface layers by means of nuclear-reaction analysis; Darstellung eines Referenzmaterials fuer die ortsaufgeloeste Wasserstoffanalytik in oberflaechennahen Schichten mittels Kernreaktionsanalyse

    Energy Technology Data Exchange (ETDEWEB)

    Reinholz, U.

    2005-10-03

    The object of the thesis is the presentation of the theory of the {sup 15}N-reaction analysis (NRA), the experiemental construction of the corresponding beam pipe at the ion accelerator of the BAM and the evaluation of the measurement results. The aim is the first characterization of a reference material for the H analytics on the base of amorphous silicon (aSi) on a Si[100] substrate. The homogeneity of the aSi:H layers deposited by means of CVD was studied. For this pro substrate for about 30 samples the hydrogen depth profiles were measures, folded by means of a program created within the thesis and subjected to a statistical evaluation. The result were mean value ans standard deviation of the hydrogen concentration as well as an estimator for the contribution of the inhomogeneity to the measurement uncertainty. The stability of the potential reference material was proved by the constancy of result of repeated measurements of the hydrogen concentration during the application of a large dose of {sup 15}N ions. In an international ring experiment the reproducibility of the measurement results was proved. For the characterization of the aSi:H layers beside the NRA the white-light interferometry, ellipsometry, profilometry, and X-ray reflectometry, as well as the IR and Raman spectroscopy were used. The stoichiometry of the applied standard material kapton was checked by means of NMR spectroscopy and CHN analysis.