  1. Initial mechanical stability of cementless highly-porous titanium tibial components

    Energy Technology Data Exchange (ETDEWEB)

    Stone, Timothy Brandon [Los Alamos National Laboratory; Amer, Luke D [Los Alamos National Laboratory; Warren, Christopher P [Los Alamos National Laboratory; Cornwell, Phillip [Los Alamos National Laboratory; Meneghini, R Michael [UNIV OF CONNECTICUT HEALTH CENTER

    2008-01-01

    Cementless fixation in total knee replacement has seen limited use since reports of early failure surfaced in the late 80s and early 90s. However the emergence of improved biomaterials, particularly porous titanium and tantalum, has led to a renewed interest in developing a cementless tibial component to enhance long-term survivorship of the implants. Cement is commonly employed to minimize micromotion in new implants but represents a weak interface between the implant and bone. The elimination of cement and application of these new biomaterials, which theoretically provide improved stability and ultimate osseointegration, would likely result in greater knee replacement success. Additionally, the removal of cement from the procedure would help minimize surgical durations and get rid of the time needed for curing, thereby the chance of infection. The purpose of this biomechanical study was twofold. The first goal was to assess whether vibration analysis techniques can be used to evaluate and characterize initial mechanical stability of cementless implants more accurately than the traditional method of micromotion determination, which employs linear variable differential transducers (LVDTs). Second, an evaluative study was performed to determine the comparative mechanical stability of five designs of cementless tibial components under mechanical loading designed to simulate in vivo forces. The test groups will include a cemented Triathlon Keeled baseplate control group, three different 2-peg cementless baseplates with smooth, mid, and high roughnesses and a 4-peg cement/ess baseplate with mid-roughness.

  2. Fatigue behavior of highly porous titanium produced by powder metallurgy with temporary space holders.

    Science.gov (United States)

    Özbilen, Sedat; Liebert, Daniela; Beck, Tilmann; Bram, Martin

    2016-03-01

    Porous titanium cylinders were produced with a constant amount of temporary space holder (70 vol.%). Different interstitial contents were achieved by varying the starting powders (HDH vs. gas atomized) and manufacturing method (cold compaction without organic binders vs. warm compaction of MIM feedstocks). Interstitial contents (O, C, and N) as a function of manufacturing were measured by chemical analysis. Samples contained 0.34-0.58 wt.% oxygen, which was found to have the greatest effect on mechanical properties. Quasi-static mechanical tests under compression at low strain rate were used for reference and to define parameters for cyclic compression tests. Not unexpectedly, increased oxygen content increased the yield strength of the porous titanium. Cyclic compression fatigue tests were conducted using sinusoidal loading in a servo-hydraulic testing machine. Increased oxygen content was concomitant with embrittlement of the titanium matrix, resulting in significant reduction of compression cycles before failure. For samples with 0.34 wt.% oxygen, R, σ(min) and σ(max) were varied systematically to estimate the fatigue limit (~4 million cycles). Microstructural changes induced by cyclic loading were then characterized by optical microscopy, SEM and EBSD.

  3. Cementless Titanium Mesh Fixation of Osteoporotic Burst Fractures of the Lumbar Spine Leads to Bony Healing: Results of an Experimental Sheep Model

    Directory of Open Access Journals (Sweden)

    Anica Eschler

    2016-01-01

    Full Text Available Introduction. Current treatment strategies for osteoporotic vertebral compression fractures (VCFs focus on cement-associated solutions. Complications associated with cement application are leakage, embolism, adjacent fractures, and compromise in bony healing. This study comprises a validated VCF model in osteoporotic sheep in order to (1 evaluate a new cementless fracture fixation technique using titanium mesh implants (TMIs and (2 demonstrate the healing capabilities in osteoporotic VCFs. Methods. Twelve 5-year-old Merino sheep received ovariectomy, corticosteroid injections, and a calcium/phosphorus/vitamin D-deficient diet for osteoporosis induction. Standardized VCFs (type AO A3.1 were created, reduced, and fixed using intravertebral TMIs. Randomly additional autologous spongiosa grafting (G1 or no augmentation was performed (G2, n=6 each. Two months postoperatively, macroscopic, micro-CT and biomechanical evaluation assessed bony consolidation. Results. Fracture reduction succeeded in all cases without intraoperative complications. Bony consolidation was proven for all cases with increased amounts of callus development for G2 (58.3%. Micro-CT revealed cage integration. Neither group showed improved results with biomechanical testing. Conclusions. Fracture reduction/fixation using TMIs without cement in osteoporotic sheep lumbar VCF resulted in bony fracture healing. Intravertebral application of autologous spongiosa showed no beneficial effects. The technique is now available for clinical use; thus, it offers an opportunity to abandon cement-associated complications.

  4. Hydroxyapatite in total hip arthroplasty. Our experience with a plasma spray porous titanium alloy/hydroxyapatite double-coated cementless stem

    Science.gov (United States)

    Castellini, Iacopo; Andreani, Lorenzo; Parchi, Paolo Domenico; Bonicoli, Enrico; Piolanti, Nicola; Risoli, Francesca; Lisanti, Michele

    2016-01-01

    Summary Purpose Total hip arthroplasty could fail due to many factors and one of the most common is the aseptic loosening. In order to achieve an effective osseointegration and reduce risk of lossening, the use of cemented implant, contact porous bearing surface and organic coating were developed. Aim of this study was to evaluate clinical and radiological mid-term outcomes of a porous titanium alloy/hydroxyapatite double coating manufactured cementless femoral stem applied with “plasma spray” technique and to demonstrate the possibility to use this stem in different types of femoral canals. Methods Between January 2008 and December 2012, 240 consecutive primary total hip arthroplasties (THAs) were performed using a porous titanium alloy/hydroxyapatite double coating manufactured cementless femoral stem. 182 patients were examined: 136 were females (74.7%) and 46 males (25.2%); average age was 72 years old (ranging from 26 to 92 years old). For each patient, Harris Hip Scores (HHS) and Womac Scores were collected. All X-ray images were analyzed in order to demonstrate stem survival rate and subsidence. Results Harris Hip Score was good or excellent in 85% of the cases (average 90%) and mean WOMAC score was 97.5 (ranging from 73.4 to 100). No cases of early/late infection or periprosthetic fracture were noticed, with an excellent implant survival rate (100%) in a mean period of 40 months (ranging from 24 and 84 months). 5 cases presented acute implant dislocation, 2 due to wrong cup positioning in a dysplastic acetabulum and 3 after ground level fall. Dorr classification of femoral geometry was uses and the results were: 51 type A bone, 53 type B bone and 78 type C bone. Stem subsidence over 2 mm was considered as a risk factor of future implant loosening and was evidenced in 3 female patients with type C of Dorr classification. No radiolucencies signs around the proximally coated portion of stem or proximal reabsorption were visible during the radiographic

  5. Effects of femoral component material properties on cementless fixation in total hip arthroplasty. A comparison study between carbon composite, titanium alloy, and stainless steel.

    Science.gov (United States)

    Otani, T; Whiteside, L A; White, S E; McCarthy, D S

    1993-02-01

    Carbon-fiber-reinforced-carbon composite material is an attractive implant material because its modulus of elasticity can be made similar to that of cortical bone. This study investigated the effect of femoral prosthesis elastic modulus on cementless implant fixation. Distal, as well as proximal, relative micromovements between implant and bone were measured in two testing protocols (axial-load and torsional-load), comparing identically shaped carbon composite (modulus of elasticity = 18.6 GPa), Ti6Al4V (100 GPa), and 630 stainless steel (200 GPa) prostheses. In the axial-load test, proximal mediolateral micromotions were significantly larger in the flexible composite stem than in the two metals. In the torsional-load test, rotational micromotions and "slop" displacements in the flexible stem were significantly larger proximally and significantly smaller distally than in the two metals. While these results suggest that proximal stress transfer may be improved by a flexible stem, they raise the possibility of increased proximal micromotion, and suggest that improved proximal fixation may be necessary to achieve clinical success with flexible composite femoral components.

  6. Good performance of a titanium femoral component in cementless hip arthroplasty in younger patients: 97 arthroplasties followed for 5-11 years

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Jensen, Frank Krieger; Poulsen, Klaus

    2003-01-01

    We performed 97 uncemented primary total hip arthroplasties in 80 patients having an average age of 50 years. The femoral implant was a titanium stem with a proximal circumferential plasma spray-coating. Three different acetabular components were used: a threaded and partly porous-coated design...... osteolysis associated with a deep infection, but no signs of proximal loosening. 3 femora had areas of minor proximal osteolysis. 16 acetabular components (14 threaded) had been revised in 13 patients. The average Harris hip score was 91 points at the latest follow-up. We conclude that the uncemented...... titanium femoral component with a circumferential porous coating performed well in these patients, most of whom were young. As reported previously, aseptic loosening of threaded acetabular components was common....

  7. Cementless Hydroxyapatite Coated Hip Prostheses

    Directory of Open Access Journals (Sweden)

    Antonio Herrera

    2015-01-01

    Full Text Available More than twenty years ago, hydroxyapatite (HA, calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical experience includes the implantation of more than 4,000 cementless hydroxyapatite coated hip prostheses since 1990. The models implanted are coated with HA in the acetabulum and in the metaphyseal area of the stem. The results corresponding to survival and stability of implants were very satisfactory in the long-term. From our experience, HA-coated hip implants are a reliable alternative which can achieve long term survival, provided that certain requirements are met: good design selection, sound choice of bearing surfaces based on patient life expectancy, meticulous surgical technique, and indications based on adequate bone quality.

  8. Antibacterial Efficacy of a New Gentamicin-Coating for Cementless Prostheses Compared to Gentamicin-Loaded Bone Cement

    NARCIS (Netherlands)

    Neut, Danielle; Dijkstra, Rene J. B.; Thompson, Jonathan I.; van der Mei, Henny C.; Busscher, Henk J.

    2011-01-01

    Cementless prostheses are increasingly popular but require alternative prophylactic measures than the use of antibiotic-loaded bone cements. Here, we determine the 24-h growth inhibition of gentamicin-releasing coatings from grit-blasted and porous-coated titanium alloys, and compare their antibacte

  9. Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    van Raaij Jos JAM

    2008-10-01

    Full Text Available Abstract Background Osteoarthritis of the hip is successfully treated by total hip arthroplasty with metal-on-polyethylene articulation. Polyethylene wear debris can however lead to osteolysis, aseptic loosening and failure of the implant. Large head metal-on-metal total hip arthroplasty may overcome polyethylene wear induced prosthetic failure, but can increase systemic cobalt and chromium ion concentrations. The objective of this study is to compare two cementless total hip arthroplasties: a conventional 28 mm metal-on-polyethylene articulation and a large head metal-on-metal articulation. We hypothesize that the latter arthroplasties show less bone density loss and higher serum metal ion concentrations. We expect equal functional scores, greater range of motion, fewer dislocations, fewer periprosthetic radiolucencies and increased prosthetic survival with the metal-on-metal articulation. Methods A randomized controlled trial will be conducted. Patients to be included suffer from non-inflammatory degenerative joint disease of the hip, are aged between 18 and 80 and are admitted for primary cementless unilateral total hip arthroplasty. Patients in the metal-on-metal group will receive a cementless titanium alloy acetabular component with a cobalt-chromium liner and a cobalt-chromium femoral head varying from 38 to 60 mm. Patients in the metal-on-polyethylene group will receive a cementless titanium alloy acetabular component with a polyethylene liner and a 28 mm cobalt-chromium femoral head. We will assess acetabular bone mineral density by dual energy x-ray absorptiometry (DEXA, serum ion concentrations of cobalt, chromium and titanium, self reported functional status (Oxford hip score, physician reported functional status and range of motion (Harris hip score, number of dislocations and prosthetic survival. Measurements will take place preoperatively, perioperatively, and postoperatively (6 weeks, 1 year, 5 years and 10 years. Discussion

  10. Higher reliability of triple-phase bone scintigraphy in cementless total hip arthroplasty compared to cementless bipolar hemiarthroplasty

    Directory of Open Access Journals (Sweden)

    Burak Yoldas

    2016-09-01

    Conclusions: Due to the higher sensitivity, specificity and accuracy, TPBS has a more reliable diagnostic value for cementless THA in the diagnosis of periprosthetic infection compared to cementless BHA.

  11. Comparison of a novel porous titanium construct (Regenerex®) to a well proven porous coated tibial surface in cementless total knee arthroplasty - A prospective randomized RSA study with two-year follow-up

    DEFF Research Database (Denmark)

    Winther, Nikolaj S; Jensen, Claus L; Jensen, Claus M

    2016-01-01

    BACKGROUND: Regenerex is a novel porous titanium construct with a three-dimensional porous structure and biomechanical characteristics close to that of normal trabecular bone. The aim of this study was to compare this novel construct to a well-proven porous plasma sprayed tibial (PPS) implant aft.......04). CONCLUSION: In conclusion the Regenerex implant could prove an effective scaffold material for coating of uncemented implants but did no better than the PPS component at 24months of follow-up. ClinicalTrials.gov identifier: NCT01936415....

  12. MECHANICAL STRENGTH OF HIGHLY POROUS CERAMICS

    NARCIS (Netherlands)

    VANDENBORN, IC; SANTEN, A; HOEKSTRA, HD; DEHOSSON, JTM; Born, I.C. van den

    1991-01-01

    This paper reports on the mechanical strength of highly porous ceramics in terms of the Weibull and Duxbury-Leath distributions. More than 1000 side-crushing strength tests on silica-catalyst carriers of various particle sizes have been performed in series. Within a series, preparation conditions we

  13. Titanium

    DEFF Research Database (Denmark)

    Fage, Simon W; Muris, Joris; Jakobsen, Stig S;

    2016-01-01

    most of the studies reviewed have important limitations, Ti seems not to penetrate a competent skin barrier, either as pure Ti, alloy, or as Ti oxide NPs. However, there are some indications of Ti penetration through the oral mucosa. We conclude that patch testing with the available Ti preparations......Exposure to titanium (Ti) from implants and from personal care products as nanoparticles (NPs) is common. This article reviews exposure sources, ion release, skin penetration, allergenic effects, and diagnostic possibilities. We conclude that human exposure to Ti mainly derives from dental...... for detection of type IV hypersensitivity is currently inadequate for Ti. Although several other methods for contact allergy detection have been suggested, including lymphocyte stimulation tests, none has yet been generally accepted, and the diagnosis of Ti allergy is therefore still based primarily on clinical...

  14. Osseointegration: a review of the fundamentals for assuring cementless skeletal fixation

    Directory of Open Access Journals (Sweden)

    Isaacson BM

    2014-04-01

    Full Text Available Brad M Isaacson,1,2 Sujee Jeyapalina3,4 1Henry M Jackson Foundation for the Advancement of Military Medicine, 2The Center for Rehabilitation Sciences Research, Department of Physical Medicine and Rehabilitation, Uniformed Services University of Health Sciences, Bethesda, MD, USA; 3Department of Orthopedics, 4Orthopedic Research Laboratory, University of Utah, Salt Lake City, UT, USA Abstract: Direct skeletal fixation, termed osseointegration, has expanded in the last century and includes use in total joint replacements, the edentulous mandible and maxilla, and percutaneous osseointegrated prosthetics. Although it is well known that titanium and bone have the ability to form a durable bone–implant interface, new applications have emerged in the field of orthopedics, which requires a more thorough assessment of the literature. This review aims to introduce the basic biological principles for attaining osseointegration and discusses the major factors for assuring successful cementless fixation. Keywords: osseointegration, bone, skeletal attachment, total joint replacements, dental implants, percutaneous

  15. Improved design of cementless hip stems using two-dimensional functionally graded materials.

    Science.gov (United States)

    Hedia, H S; Shabara, M A N; El-Midany, T T; Fouda, N

    2006-10-01

    Increasingly, it is acknowledged that bone resorption around cementless hip implants may cause future problems. The solution is frequently sought in reducing implant stiffness. However, this confronts the designer with a true design conflict: how to reduce the stiffness without excessively loading the proximal bone/prosthesis interface? The aim of this work is to improve the design of cementless hip stem material, using two-dimensional (2D) functionally graded material (FGM) concept in order to solve the above problems. Two models were used in this analysis, using three materials with different elastic moduli, E(1), E(2), and E(3). In model I, the elastic moduli E(1) and E(2) gradually change along the upper stem surface, while E(3) is maintained constant along all the lower surface of the stem. However, in model II, the elastic moduli E(1) and E(2) gradually change along the lower stem surface, while E(3) is maintained constant all along the upper stem surface. It is found that the recommended model is model I, which has three distinct materials of hydroxyapatite, Bioglass, and collagen. The recommended design of 2D FGM is expected to reduce the stress shielding by 91% and 12%, respectively, compared with titanium stem and model II of FGM. It is found that this new design reduces the maximum interface shear stress at the lateral and medial sides of the femur by about 50%, compared with titanium stem. Furthermore, the maximum interface shear stress is reduced by about 17% and 11% at the lateral and medial sides of the femur, respectively, compared with that of model II of FGM.

  16. A Femur-Implant Model for the Prediction of Bone Remodeling Behavior Induced by Cementless Stem

    Institute of Scientific and Technical Information of China (English)

    He Gong; Lingyan Kong; Rui Zhang; Juan Fang; Meisheng Zhao

    2013-01-01

    Bone remodeling simulation is an effective tool for the prediction of long-term effect of implant on the bone tissue,as well as the selection of an appropriate implant in terms of architecture and material.In this paper,a finite element model of proximal femur was develop.ed to simulate the structures of internal trabecular and cortical bones by incorporating quantitative bone functional adaptation theory with finite element analysis.Cementless stems made of titanium,two types of Functionally Graded Material (FGM) and flexible 'iso-elastic' material as comparison were implanted in the structure of proximal femur respectively to simulate the bone remodeling behaviors of host bone.The distributions of bone density,von Mises stress,and interface shear stress were obtained.All the prosthetic stems had effects on the bone remodeling behaviors of proximal femur,but the degrees of stress shielding were different.The amount of bone loss caused by titanium implant was in agreement with the clinical observation.The FGM stems caused less bone loss than that of the titanium stem,in which FGM I stem (titanium richer at the top to more HAP/Col towards the bottom) could relieve stress shielding effectively,and the interface shear stresses were more evenly distributed in the model with FGM I stem in comparison with those in the models with FGM II (titanium and bioglass) and titanium stems.The numerical simulations in the present study provided theoretical basis for FGM as an appropriate material of femoral implant from a biomechanical point of view.The next steps are to fabricate FGM stem and to conduct animal experiments to investigate the effects of FGM stem on the remodeling behaviors using animal model.

  17. Modified cementless total coxofemoral prosthesis: development, implantation and clinical evaluation

    Directory of Open Access Journals (Sweden)

    S.A. Arias

    2013-12-01

    Full Text Available The aim of this study was to modify canine coxofemoral prostheses and the clinical evaluation of the implantation. Fifteen canine hips and femora of cadavers were used in order to study the surface points of modification in prostheses and develop a perforation guide. Femoral stems and acetabular components were perforated and coated with biphasic calcium phosphate layer. Twelve young adult male mongrel dogs were implanted with coxofemoral prostheses. Six were operated upon and implanted with cemented canine modular hip prostheses, establishing the control group. The remaining six were implanted with a novel design of cementless porous tricalcic phosphate-hydroxyapatite coated hip prostheses. Clinical and orthopedic performance, complications, and thigh muscular hypotrophy were assessed up to the 120th post-operatory day. After 120 days, animals with cementless prostheses had similar clinical and orthopedic performance compared to the cemented group despite the increased pain thigh hypotrophy. Animals that underwent cementless hip prosthesis evidenced more pain, compared to animals with cemented hip prosthesis that required longer recuperation time. No luxations, two fractures and two isquiatic neurapraxies were identified in the course of the study. Using both the cemented and the bioactive coated cementless model were suitable to dogs, showing clinical satisfactory results. Osseointegration and biological fixation were observed in the animals with the modified cementless hip prosthesis.

  18. Cementless bipolar hemiarthroplasty in femoral neck fractures in elderly

    Directory of Open Access Journals (Sweden)

    SKS Marya

    2011-01-01

    Conclusion: Cementless bipolar hemiarthroplasty for femoral neck fractures in the very elderly permits early return to premorbid life and is not associated with any untoward cardiac event in the perioperative period. It can be considered a treatment option in this select group.

  19. Bone regeneration performance of surface-treated porous titanium

    NARCIS (Netherlands)

    Amin Yavari, Saber; Stok, Johan; Chai, Yoke Chin; Wauthle, Ruben; Thamasebi Birgani, Zeinab; Habibovic, Pamela; Mulier, Michiel; Schrooten, Jan; Weimans, Harrie; Zadpoor, Amir Abbas

    2014-01-01

    The large surface area of highly porous titanium structures produced by additive manufacturing can be modified using biofunctionalizing surface treatments to improve the bone regeneration performance of these otherwise bioinert biomaterials. In this longitudinal study, we applied and compared three

  20. Design optimization of cementless metal-backed cup prostheses using the concept of functionally graded material.

    Science.gov (United States)

    Hedia, H S; El-Midany, T T; Shabara, M A N; Fouda, N

    2006-09-01

    Metal backing has been widely used in acetabular cup design. A stiff backing for a polyethylene liner was initially believed to be mechanically favourable. Yet, recent studies of the load transfer around acetabular cups have shown that a stiff backing causes two problems. It generates higher stress peaks around the acetabular rim than those caused by full polyethylene cups and reduces the stresses transferred to the dome of the acetabulum causing stress shielding. The aim of this study is to overcome these two problems by improving the design of cementless metal-backed acetabular cups using the two-dimensional functionally graded material (FGM) concept through finite-element analysis and optimization techniques. It is found that the optimal 2D FGM model must have three bioactive materials of hydroxyapatite, Bioglass and collagen. This optimal material reduces the stress shielding at the dome of the acetabulum by 40% and 37% compared with stainless steel and titanium metal backing shells, respectively. In addition, using the 2D FGM model reduces the maximum interface shear stress in the bone by 31% compared to the titanium metal backing shell.

  1. Design optimization of cementless metal-backed cup prostheses using the concept of functionally graded material

    Energy Technology Data Exchange (ETDEWEB)

    Hedia, H S; El-Midany, T T; Shabara, M A N; Fouda, N [Production Engineering and M/C Design Department, Faculty of Engineering, Mansoura University, Mansoura (Egypt)

    2006-09-15

    Metal backing has been widely used in acetabular cup design. A stiff backing for a polyethylene liner was initially believed to be mechanically favourable. Yet, recent studies of the load transfer around acetabular cups have shown that a stiff backing causes two problems. It generates higher stress peaks around the acetabular rim than those caused by full polyethylene cups and reduces the stresses transferred to the dome of the acetabulum causing stress shielding. The aim of this study is to overcome these two problems by improving the design of cementless metal-backed acetabular cups using the two-dimensional functionally graded material (FGM) concept through finite-element analysis and optimization techniques. It is found that the optimal 2D FGM model must have three bioactive materials of hydroxyapatite, Bioglass and collagen. This optimal material reduces the stress shielding at the dome of the acetabulum by 40% and 37% compared with stainless steel and titanium metal backing shells, respectively. In addition, using the 2D FGM model reduces the maximum interface shear stress in the bone by 31% compared to the titanium metal backing shell.

  2. Preparation of the Femoral Bone Cavity for Cementless Stems

    DEFF Research Database (Denmark)

    Hjorth, Mette H; Kold, Søren; Søballe, Kjeld;

    2016-01-01

    BACKGROUND: Short-term experimental and animal studies have confirmed superior fixation of cementless implants inserted with compaction compared to broaching of the cancellous bone. METHODS: Forty-four hips in 42 patients (19 men) were randomly operated using cementless hydroxyapatite-coated Bi......-Metric stems. Patients were followed with radiostereometric analysis at baseline, 6 and 12 weeks, 1, 2, and 5 years, and measurements of periprosthetic bone mineral density at baseline, 1, 2, and 5 years. Complications during the study period and clinical outcome measures of Harris Hip Score were recorded...... follow-ups (P > .13). The compaction group had significantly less bone loss than the broaching group in Gruen zone 3 (distal-lateral to the stem) at 1 and 5 years. No further differences in bone mineral density changes were found between groups up to 5 years after surgery. Complications throughout...

  3. PRIMARY CEMENTLESS TOTAL HIP ARTHROPLASTY IN ANKYLOSING SPONDYLITIS

    Directory of Open Access Journals (Sweden)

    Nageshwara Rao

    2015-12-01

    Full Text Available INTRODUCTION Ankylosing Spondylitis (AS, family of Spondyloarthritides (SpAs, is a chronic inflammatory disease affecting the axial skeleton, the entheses and occasionally the peripheral joints. The shoulders and hips are considered axial joints and involvement occurs in up to 50% of patients and is more common than involvement of the more distal joints. Aim of our study is to evaluate outcome of Cementless Total Hip Arthroplasty (THA in ankylosing spondylitis. MATERIALS AND METHODS We prospectively and retrospectively reviewed 27 hips in 20 patients who underwent cementless THA between 2007-2013. Mean age of patient was 31.5 years. We analysed demographic data, preoperative deformity, Harris Hip Score, ambulatory status, need for walking aids. RESULTS All patients experienced significant improvement in function, range of motion, posture and ambulation. Postoperative Harris Hip Score improved from 18.95 to 89.35; 90% are completely pain free, 5% have occasional discomfort and 5% have mild-to-moderate pain. CONCLUSION Cementless THA for deformed hips in young patients with AS is worthwhile surgical intervention, as it increases the mobility of the patient, improves the ability to sit comfortably, decrases the morbidity of the disease. However, the technically demanding nature of the procedure should not be underestimated.

  4. Experimental investigation for cavity dimensions of highly porous small bodies

    Science.gov (United States)

    Okamoto, T.; Nakamura, A.; Hasegawa, S.

    2014-07-01

    Small bodies were probably very porous during the formation of the solar system. In order to understand the surface evolution of highly porous bodies, it is necessary to investigate the impact process for targets with such high porosity. In this study, impact experiments with sintered glass-bead targets of 87 and 94 % porosities were conducted. Growth of cavities with time and the final cavity dimensions were analyzed and compared with previous studies of porous targets. Impact experiments were conducted using a two-stage light-gas gun at ISAS, Japan. The projectiles of a few millimeters were composed of titanium, aluminum, nylon, and basalt. The impact velocities ranged from 1.8 to 7.2 km s^{-1}. In order to observe the inside of the targets, we used a flash X-ray system and a micro-X-ray tomography instrument. The track shape was found to be divided into two types, elongated 'carrot' shape and short 'bulb' shape [1]. The figures on the left and right present a transmission image of the bulb shape track and a sketch of a cross section of the cavity, respectively. The results of the final maximum diameter, D_max and the final entrance-hole diameter, D_ent show that both dimensions tend to increase with impact velocity and decrease with target porosity. We adopted the scaling law of crater diameter [2] for our analysis of D_max and D_ent. The following empirical relations are obtained for targets with porosity ≥ 87 %: {D_max}/{d_p}(ρ_t/ρ_p)^{0.4} =10^{-1.52±0.27} ({Y}/ρ_t{v_0^2})^{-0.49 ± 0.07}, {D_ent}/{d_p}(ρ_t/ρ_p)^{0.4} =10^{-2.12±0.39} ({Y}/ρ_t{v_0^2})^{-0.53 ± 0.11}, where d_p, ρ_t, ρ_p, Y, and v_0 are the projectile diameter, target density, projectile density, target compressive strength, and the impact velocity, respectively. The results of the depth from the entrance hole to the maximum diameter of the cavity, L_max, shows that L_max decreases with impact velocity and increases with target porosity. If we assume that a projectile decelerates

  5. Highly porous nanoberyllium for X-ray beam speckle suppression

    Energy Technology Data Exchange (ETDEWEB)

    Goikhman, Alexander, E-mail: agoikhman@ymail.com; Lyatun, Ivan; Ershov, Petr [Immanuel Kant Baltic Federal University, Nevskogo str. 14, Kaliningrad 236041 (Russian Federation); Snigireva, Irina [European Synchrotron Radiation Facility, BP 220, 38043 Grenoble (France); Wojda, Pawel [Immanuel Kant Baltic Federal University, Nevskogo str. 14, Kaliningrad 236041 (Russian Federation); Gdańsk University of Technology, 11/12 G. Narutowicza, Gdańsk 80-233 (Poland); Gorlevsky, Vladimir; Semenov, Alexander; Sheverdyaev, Maksim; Koletskiy, Viktor [A. A. Bochvar High-Technology Scientific Research Institute for Inorganic Materials, Rogova str. 5a, Moscow 123098 (Russian Federation); Snigirev, Anatoly [Immanuel Kant Baltic Federal University, Nevskogo str. 14, Kaliningrad 236041 (Russian Federation); European Synchrotron Radiation Facility, BP 220, 38043 Grenoble (France)

    2015-04-09

    A speckle suppression device containing highly porous nanoberyllium is proposed for manipulating the spatial coherence length and removing undesirable speckle structure during imaging experiments. This paper reports a special device called a ‘speckle suppressor’, which contains a highly porous nanoberyllium plate squeezed between two beryllium windows. The insertion of the speckle suppressor in an X-ray beam allows manipulation of the spatial coherence length, thus changing the effective source size and removing the undesirable speckle structure in X-ray imaging experiments almost without beam attenuation. The absorption of the nanoberyllium plate is below 1% for 1 mm thickness at 12 keV. The speckle suppressor was tested on the ID06 ESRF beamline with X-rays in the energy range from 9 to 15 keV. It was applied for the transformation of the phase–amplitude contrast to the pure amplitude contrast in full-field microscopy.

  6. Breket titanium (Titanium bracket

    Directory of Open Access Journals (Sweden)

    Sianiwati Goenharto

    2005-09-01

    Full Text Available There has been a considerable discussion in the literature about corrosion and sensitivity to the nickel present in stainless steel brackets. Titanium has been heralded as a material totally compatible in the oral environment and superior in structural integrity compared to stainless steel. Many current applications in dentistry and medicine have made titanium an obvious choice for a possible substitute material. Titanium based brackets have shown excellent corrosion resistance and possessed good biocompatibility. Evaluation of titanium brackets for orthodontic therapy showed that titanium brackets were comparable to stainless steel brackets in passive and active configuration. Study about metallographic structure, hardness, bond strength to enamel substrate, etc. showed that titanium brackets exhibited a potential for clinical application. It was concluded that titanium brackets were suitable substitute for stainless steel brackets.

  7. Instationary compaction wave propagation in highly porous cohesive granular media

    Science.gov (United States)

    Gunkelmann, Nina; Ringl, Christian; Urbassek, Herbert M.

    2016-07-01

    We study the collision of a highly porous granular aggregate of adhesive \\upmu m-sized silica grains with a hard wall using a granular discrete element method. A compaction wave runs through the granular sample building up an inhomogeneous density profile. The compaction is independent of the length of the aggregate, within the regime of lengths studied here. Also short pulses, as they might be exerted by a piston pushing the granular material, excite a compaction wave that runs through the entire material. The speed of the compaction wave is larger than the impact velocity but considerably smaller than the sound speed. The wave speed is related to the compaction rate at the colliding surface and the average slope of the linear density profile.

  8. THE HIGH VOLUME REUSE OF HYBRID BIOMASS ASH AS A PRIMARY BINDER IN CEMENTLESS MORTAR BLOCK

    Directory of Open Access Journals (Sweden)

    Cheah Chee Ban

    2014-01-01

    Full Text Available High Calcium Wood Ash (HCWA and Pulverised Fuel Ash (PFA are by-products from the wood biomass and coal energy production which are produced in large quantity with combined annual production of 500 million tonnes. This poses a serious problem for disposal of the waste material especially at places where land is scarce. The prescribed study was aimed to examine the mineralogical phases and their respective amount present in the industrial wastes which governs the hydration mechanism towards self-sustained solidification of the ashes when used in combination. Besides, the influence of various forming pressure and hydrothermal treatment temperature on mechanical strength performance of HCWA-PFA cementless mortar blocks was also examined. In the study, the mechanical strength of the HCWA-PFA cementless mortar block produced using various forming pressure and hydrothermal treatment temperature was assessed in terms of compressive strength and dynamic modulus. The results of the study are indicative that HCWA is rich in calcium oxide and potassium oxide content. This enables the hybridization of HCWA with the amorphous silica and alumina rich PFA to form a solid geopolymer binder matrix for fabrication of cementless mortar block. Throughout the study, dimensionally and mechanically stable HCWA-PFA geopolymer mortar blocks were successfully produced by press forming and hydrothermal treatment method. Based on statistical analysis, the hydrothermal treatment temperature has a statistically insignificant effect on the mechanical strength of the HCWA-PFA cementless mortar blocks. The dominant factor which governs the mechanical strength of the HCWA-PFA cementless mortar blocks was found to be the hydraulic forming pressure. Moreover, it was found that hybridized HCWA-PFA can be recycled as the sole binder for fabrication of cementless concrete block which is a useful construction material.

  9. Study of bone remodeling of two models of femoral cementless stems by means of DEXA and finite elements

    Directory of Open Access Journals (Sweden)

    López-Prats Fernando

    2010-05-01

    Full Text Available Abstract Background A hip replacement with a cemented or cementless femoral stem produces an effect on the bone called adaptive remodelling, attributable to mechanical and biological factors. All of the cementless prostheses designs try to achieve an optimal load transfer in order to avoid stress-shielding, which produces an osteopenia. Long-term densitometric studies taken after implanting ABG-I and ABG-II stems confirm that the changes made to the design and alloy of the ABG-II stem help produce less proximal atrophy of the femur. The simulation with FE allowed us to study the biomechanical behaviour of two stems. The aim of this study was, if possible, to correlate the biological and mechanical findings. Methods Both models with prostheses ABG-I and II have been simulated in five different moments of time which coincide with the DEXA measurements: postoperative, 6 months, 1, 3 and 5 years, in addition to the healthy femur as the initial reference. For the complete comparative analysis of both stems, all of the possible combinations of bone mass (group I and group II of pacients in two controlled studies for ABG-I and II stems, respectively, prosthetic geometry (ABG-I and ABG-II and stem material (Wrought Titanium or TMZF were simulated. Results and Discussion In both groups of bone mass an increase of stress in the area of the cancellous bone is produced, which coincides with the end of the HA coating, as a consequence of the bottleneck effect which is produced in the transmission of loads, and corresponds to Gruen zones 2 and 6, where no osteopenia can be seen in contrast to zones 1 and 7. Conclusions In this study it is shown that the ABG-II stem is more effective than the ABG-I given that it generates higher tensional values on the bone, due to which proximal bone atrophy diminishes. This biomechanical behaviour with an improved transmission of loads confirmed by means of FE simulation corresponds to the biological findings obtained with

  10. A study of the mechanical properties of highly porous ceramics using acoustic emission

    NARCIS (Netherlands)

    Aué, J.; Hosson, J.Th.M. De

    1998-01-01

    In this paper the results of indirect tensile tests on highly porous ceramics are presented. A relation between the mechanical strength of the highly porous ceramic materials and Acoustic Emission (AE) has been established. We have shown that the amplitude distribution of the AE events depends on th

  11. Persistent photoconductivity in highly porous ZnO films

    Science.gov (United States)

    Reemts, Jens; Kittel, Achim

    2007-01-01

    ZnO and ZnO-dye hybrid films prepared by electrochemical deposition are highly porous if fabricated in the presence of structure directing agents and they can easily be sensitized by various molecules. If the material is sensitized with the appropriate molecules, it becomes interesting for various sensor applications, i.e., gas sensors and biosensors, or as an electrode material for solar energy conversion in dye sensitized solar cells. In the present work, the focus is on dye sensitized ZnO as a model system. The long term photoconductivity transients have been investigated in such kind of material. Upon excitation with different wavelengths, the conductivity increases already under sub-band-gap illumination due to widely distributed trap states within the band gap. The slow photoconductivity transients follow a stretched exponential law if the illumination is rapidly changing in a dry atmosphere. The underlying mechanism of persistent photoconductivity can be attributed to a lattice relaxation process of surface states, immediately after electrons have been photoexcited into distributed surface states located inside the band gap of the ZnO thin film.

  12. Release kinetics of highly porous floating tablets containing cilostazol.

    Science.gov (United States)

    Hwang, Kyu-Mok; Cho, Cheol-Hee; Tung, Nguyen-Thach; Kim, Ju-Young; Rhee, Yun-Seok; Park, Eun-Seok

    2017-02-20

    This study focuses on developing a highly porous floating tablet containing cilostazol. The underlying release mechanism of cilostazol from porous and floating tablets in dissolution media containing surfactants was investigated. The tablets were prepared by compressing granules and excipients with a sublimating agent, followed by sublimation under vacuum. The volatile material for the sublimating agent was chosen based on its flow properties using conventional methods as well as the twisted blade method. Resultant tablets could float immediately and had significantly higher tensile strengths than conventional tablets of similar porosities, holding a promising potential for increasing gastroretentive properties. Fitting the release profiles to the Korsmeyer-Peppas equation indicated Super Case II, Case II and non-Fickian kinetics, which implied that the release was affected by both floating behavior and matrix erosion. Abrupt changes in release kinetic parameters and erosional behaviors were found between the tablets containing different amounts of HPMC, indicating the existence of an excipient percolation threshold. Neither the surfactant in the media nor the porosity affected the dominant release mechanism, which was matrix erosion. Understanding the dominant release mechanism and percolation threshold allows for tuning the formulation to obtain various release profiles.

  13. Preparation and properties of highly porous, biomorphic YSZ ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Rambo, C.R.; Cao, J.; Sieber, H

    2004-10-15

    Highly porous, biomorphic YSZ (yttria-stabilized zirconia) ceramics were manufactured by infiltration of zirconium-oxychloride (ZrOCl{sub 2}{center_dot}8H{sub 2}O) sol into biological template structures derived from rattan and pine wood. 3-5 mol% yttrium nitrate (Y(NO{sub 3}){sub 3}{center_dot}5H{sub 2}O) was added to the sol to stabilize the tetragonal ZrO{sub 2} phase. After vacuum-assisted infiltration, the specimens were pyrolysed at 800 deg. C in N{sub 2} atmosphere. Repeated infiltrations and subsequent annealing in air at temperatures up to 1550 deg. C yields the burn out of the biocarbon template and resulted in the formation of biomorphous YSZ ceramics, which maintained the microstructural features of the biological preform. Depending on the type of the biological template as well as the processing parameters, biomorphic ZrO{sub 2} ceramics with an unidirected pore morphology and a large variety of microstructures can be obtained.

  14. Cementless acetabular fixation in patients 50 years and younger at 10 to 18 years of follow-up.

    Science.gov (United States)

    Teusink, Matthew J; Callaghan, John J; Warth, Lucian C; Goetz, Devon D; Pedersen, Douglas R; Johnston, Richard C

    2012-08-01

    The purpose of the study was to evaluate the 10- to 18-year follow-up of cementless acetabular fixation in patients 50 years and younger. We retrospectively reviewed a consecutive group of 118 patients (144 hips) in whom primary total hip arthroplasty had been performed by 2 surgeons using a cementless acetabular component. Two (1.4%) cementless acetabular components were revised because of aseptic loosening. Twenty-four hips (16.7%) were revised for any mechanical failure of the acetabular component mostly related to acetabular liner wear and osteolysis. The average linear wear rate was 0.19 mm per year, which was higher than our previous reports with cemented acetabular fixation. The fiber mesh ingrowth surface of the cementless acetabular component in this study was superior to cemented acetabular components in terms of fixation. However, the high rates of wear and osteolysis have led to poor overall acetabular component construct survivorship.

  15. Bone scans after total knee arthroplasty in asymptomatic patients. Cemented versus cementless

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, A.A.; Wyatt, R.W.; Daniels, A.U.; Armstrong, L.; Alazraki, N.; Taylor, A. Jr. (Univ. of Utah Medical Center, Salt Lake City (USA))

    1990-02-01

    The natural history of bone scans after total knee arthroplasty (TKA) was studied in 26 patients with 28 cemented TKAs and 29 patients with 31 cementless TKAs. The bone scans were examined at specified postoperative intervals. Radionuclide activity of the femoral, tibial, and patellar regions was measured. Six patients who developed pain postoperatively were excluded. Bone scans immediately postoperative and at three months demonstrated increased uptake, which gradually decreased to baseline levels at ten to 12 months. Radioisotope uptake was comparable in the cemented and cementless groups, but was highly variable in individual patients and in each of the follow-up periods. A single postoperative bone scan cannot differentiate component loosening from early bone remodeling. Sequential bone scans, as a supplement to the clinical examination and conventional radiography, may prove useful in the diagnosis of TKA failure.

  16. Effect of proximal femoral osteoporosis on cementless hip arthroplasty: A short-term clinical analysis

    Institute of Scientific and Technical Information of China (English)

    LOU Xian-feng; LI Yu-hong; LIN Xiang-jin

    2007-01-01

    Objective: The aim of this retrospective investigation was to explore the influence of femoral osteoporosis on short-term curative effects of cementless hip arthroplasty and to evaluate the femoral metaphyseal bone mineral density (BMD) for femoral osteoporosis in order to guide prosthesis choice and rehabilitation. Methods: We performed 127 total arthroplasty operations between June 1999 to February 2003 and investigated 49 cementless hip replacements with the Metalcancellous cementless Lubeck Ⅱ system being used in all hips. There were twenty men and twenty-nine women whose mean age at the time of the operation was 60 years (range, 52~81 years). The patients were divided into osteoporosis or normal groups according to the femoral metaphyseal BMD measured preoperatively. The average duration of follow-up was 30 months (range, 8~52 months). We evaluated all of the patients from a clinical standpoint with use of a standard-terminology questionnaire with respect to the short-term curative effects and patients' satisfaction. Hip pain status and functional ability were important indicators of treatment efficacy. Results: Harris hip score and patients' satisfaction in femoral osteoporosis patients who underwent noncemented hip arthroplasty were lower (P=0.004, P=0.03) while the incidence of thigh pain was higher (P=0.03) than the patients with non-osteoporosis. Conclusion: The higher incidence of pain, as well as the decrease in function experienced by the patients in osteoporosis group, supports the case that cementless arthroplasty is not a better choice for those patients and that we had better select prosthesis based on the femoral metaphyseal BMD.

  17. Total hip replacement: A meta-analysis to evaluate survival of cemented, cementless and hybrid implants

    Science.gov (United States)

    Phedy, Phedy; Ismail, H Dilogo; Hoo, Charles; Djaja, Yoshi P

    2017-01-01

    AIM To determine whether cemented, cementless, or hybrid implant was superior to the other in terms of survival rate. METHODS Systematic searches across MEDLINE, CINAHL, and Cochrane that compared cemented, cementless and hybrid total hip replacement (THR) were performed. Two independent reviewers evaluated the risk ratios of revision due to any cause, aseptic loosening, infection, and dislocation rate of each implants with a pre-determined form. The risk ratios were pooled separately for clinical trials, cohorts and registers before pooled altogether using fixed-effect model. Meta-regressions were performed to identify the source of heterogeneity. Funnel plots were analyzed. RESULTS Twenty-seven studies comprising 5 clinical trials, 9 cohorts, and 13 registers fulfilled the research criteria and analyzed. Compared to cementless THR, cemented THR have pooled RR of 0.47 (95%CI: 0.45-0.48), 0.9 (0.84-0.95), 1.29 (1.06-1.57) and 0.69 (0.6-0.79) for revision due to any reason, revision due to aseptic loosening, revision due to infection, and dislocation respectively. Compared to hybrid THR, the pooled RRs of cemented THR were 0.82 (0.76-0.89), 2.65 (1.14-6.17), 0.98 (0.7-1.38), and 0.67 (0.57-0.79) respectively. Compared to hybrid THR, cementless THR had RRs of 0.7 (0.65-0.75), 0.85 (0.49-1.5), 1.47 (0.93-2.34) and 1.13 (0.98-1.3). CONCLUSION Despite the limitations in this study, there was some tendency that cemented fixation was still superior than other types of fixation in terms of implant survival.

  18. Effect of rotator cuff dysfunction on the initial mechanical stability of cementless glenoid components

    OpenAIRE

    2009-01-01

    textabstractThe functional outcome of shoulder replacement is related to the condition of the rotator cuff. Rotator cuff disease is a common problem in candidates for total shoulder arthroplasty; this study relates the functional status of the rotator cuff to the initial stability of a cementless glenoid implant. A 3D finite element model of a complete scapula was used to quantify the effect of a dysfunctional rotator cuff in terms of bone-implant interface micromotions when the implant is ph...

  19. Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

    Directory of Open Access Journals (Sweden)

    Gholam Hossein Shahcheraghi

    2015-09-01

    Full Text Available Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations. Methods: 52 primary cementless total hip arthroplasty in 42 patients with the mean age of 48.8 years were retrospectively studied. Two groups of prosthesis had been implanted: Harris-Galante II (HGII in 15 and Versys-Trilogy (V-T in 37 hips, both from Zimmer company. The patients were assessed clinically, radiographically and with Harris hip score, SF36, WOMAC, and MACTAR questionnaires, with 65 months (26-136 mean follow-up. Results: All the V-T prostheses had survived well. Eight of HG II were revised by the last follow-up in 19-102 months. All had undergone acetabular revision and 2 combined with femoral revision. Broken tines of HGII cups were seen in 4 radiographs. The 65 months overall survival was 96.2% for femoral and 84.6% for acetabular components. 90% had good or excellent Harris hip scores. The functional scores were poorer in the HG II group. Pain relief and improved walking were the two main patients’ expectations fulfilled in 97.6% and 92.8%, respectively. Conclusions: The outcome of cementless total hip arthroplasty (THA is satisfactory and comparable with the literature based on the results of function and survival of this small comparative group. The use of HGII acetabular component should be abandoned.

  20. Comparison of Biocompatibility of Cemented vs. Cementless Hip Joint Endoprostheses Based on Postoperative Evaluation of Proinflammatory Cytokine Levels

    Science.gov (United States)

    Szypuła, Jan; Cabak, Anna; Kiljański, Marek; Boguszewski, Dariusz; Tomaszewski, Wiesław

    2016-01-01

    Background The yearly increase in the number of procedures involving implantation of hip joint endoprostheses forces prosthetics manufacturers to search for biologically neutral implants. The goal of this study was to assess the concentration of Interleukin-6 (IL-6) and its correlation with C-reactive protein (CRP), depending on the type of hip joint endoprosthesis (cemented or cementless endoprosthesis) in order to determine implant biotolerance during the early postoperative period. Material/Methods The sample comprised 200 patients [mean age=64 (31–81) years] with coxarthrosis. All patients underwent hip joint arthroplasty using a cemented or cementless endoprosthesis. Blood samples were collected 3 times: before the procedure, on the first day after the procedure, and after 6 weeks. IL-6 and CRP levels were assayed using immunoenzymatic methods. The results were subjected to statistical analysis using the Shapiro-Wilk test. Results On the 1st day after the procedure, CRP and IL-6 concentration increased rapidly after implantation of both cemented and cementless endoprostheses. At 6 weeks postoperatively, the CRP value remained at a similar level in patients after cemented arthroplasty and was almost 2-fold lower in patients who underwent cementless arthroplasty. The IL-6 value returned to the baseline level in patients after cementless arthroplasty and showed an ongoing increasing tendency in patients after cemented arthroplasty. Conclusions 1. The measurement of C-reactive protein and Interleukin-6 is a high-sensitivity test, assessing implant biotolerance. 2. The implantation of a cemented endoprosthesis induces a higher increase in the level of proinflammatory cytokines as compared with a cementless endoprosthesis. 3. For a complete assessment of both early and later body responses to implantation and the related surgical procedure, further studies using available approaches and tools are recommended. PMID:27935873

  1. Radiographic and clinical analysis of cementless acetabular fixation in total hip arthroplasty

    Institute of Scientific and Technical Information of China (English)

    ZHANG Hui; PEI Fu-xing; YANG Jing; SHEN Bin; SHI Rui

    2005-01-01

    Objective: To investigate the factors affecting the fixation, loosening and therapeutic effect of cementless acetabular prosthesis through following up the patients with total hip arthroplasty clinically and radiographically.Methods: From February 1998 to May 1999, 139 patients (148 hips) underwent total hip arthroplasty with cementless acetabular prosthesis in our department. In this study, the clinical therapeutic effect and the anteroposterior radiographs of the pelvis and anteroposterior and lateral radiographs of the hips of 109 patients (116 hips) made before operation, at 1 week, 3, 6, and 12 months after operation and annually thereafter were analyzed retrospectively. The clinical therapeutic effects were evaluated with Harris hip score. Radiographs were used to observe the position of prostheses and the bone changes around the implant, and to measure the wearing speed and direction of the acetabular cup. All evaluations were made by an independent examiner who did not participate in the operation. The patients were followed up for 5-6 years.Results: The mean Harris score was 44 points (range, 10-70 points) before operation, but it increased to 92.4 points (range, 80-100 points) at the latest review after operation, which was significantly higher than that before operation (P<0.05). No acetabular component was revised because of infection or aseptic loosening. And no acetabular component migrated. There was no revision of fixed acetabular component because of pelvic osteolysis secondary to polyethylene wear. The mean linear wear rate was 0.15 mm per year. All the acetabular prostheses were classified as stable on the radiographs.Conclusions: In terms of fixation, total hip arthroplasty with cementless acetabular components was successful. Although there is no aseptic loosening and a low incidence of osteolysis at the latest follow-up evaluation, polyethylene wear cannot be avoided and can lead to expansile osteolysis near the cups. This kind of osteolysis

  2. Growth and multiplexed analysis of microorganisms on a subdivided, highly porous, inorganic chip manufactured from anopore

    NARCIS (Netherlands)

    Ingham, C.J.; Ende, van den M.; Pijnenburg, D.; Wever, P.C.; Schneeberger, P.M.

    2005-01-01

    A highly porous inorganic material (Anopore) was shown to be an effective support for culturing and imaging a wide range of microorganisms. An inert barrier grid was printed on the rigid surface of Anopore to create a "living chip" of 336 miniaturized compartments (200/cm2) with broad applications i

  3. Stable Fixation of a Cementless, Proximally Coated, Double Wedged, Double Tapered Femoral Stem in Total Hip Arthroplasty

    DEFF Research Database (Denmark)

    Nebergall, Audrey K; Rolfson, Ola; Rubash, Harry E

    2016-01-01

    BACKGROUND: The objective of this 5-year prospective study of 51 hips was to assess migration of a cementless tapered femoral stem using radiostereometric analysis (RSA), plain radiographs (radiolucencies), and patient-reported outcome measures (PROMs). METHODS: Forty-seven patients (51 hips) agr...

  4. Digital tomosynthesis with metal artifact reduction for assessing cementless hip arthroplasty: a diagnostic cohort study of 48 patients

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Hao; Yang, Dejin; Guo, Shengjie; Tang, Jing; Liu, Jian; Wang, Dacheng; Zhou, Yixin [Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Department of Orthopaedic Surgery, Beijing (China)

    2016-11-15

    For postoperative imaging assessment of cementless hip arthroplasty, radiography and computed tomography (CT) were restricted by overlapping structures and metal artifacts, respectively. A new tomosynthesis with metal artifact reduction (TMAR) is introduced by using metal extraction and ordered subset-expectation maximization (OS-EM) reconstruction. This study investigated the effectiveness of TMAR in assessing fixation stability of cementless hip arthroplasty components. We prospectively included 48 consecutive patients scheduled for revision hip arthroplasty in our hospital, with 41 femoral and 35 acetabular cementless components available for evaluation. All patients took the three examinations of radiography, CT, and TMAR preoperatively, with intraoperative mechanical tests, and absence or presence of osteointegration on retrieved prosthesis as reference standards. Three senior surgeons and four junior surgeons evaluated these images independently with uniform criteria. For TMAR, 82 % diagnoses on the femoral side and 84 % diagnoses on the acetabular side were accurate. The corresponding values were 44 and 67 % for radiography, and 39 % and 74 % for CT. Senior surgeons had significantly higher accuracy than junior surgeons by radiography (p < 0.05), but not by TMAR or CT. By minimizing metal artifacts in the bone-implant interface and clearly depicting peri-implant trabecular structures, the TMAR technique improved the diagnostic accuracy of assessing fixation stability of cementless hip arthroplasty, and shortened the learning curve of less experienced surgeons. Level II, diagnostic cohort study. (orig.)

  5. Intra-operative evaluation of cementless hip implant stability: a prototype device based on vibration analysis.

    Science.gov (United States)

    Lannocca, Maurizio; Varini, Elena; Cappello, Angelo; Cristofolini, Luca; Bialoblocka, Ewa

    2007-10-01

    Cementless implants are mechanically stabilized during surgery by a press-fitting procedure. Good initial stability is crucial to avoid stem loosening and bone cracking, therefore, the surgeon must achieve optimal press-fitting. A possible approach to solve this problem and assist the surgeon in achieving the optimal compromise, involves the use of vibration analysis. The present study aimed to design and test a prototype device able to evaluate the primary mechanical stability of a cementless prosthesis, based on vibration analysis. In particular, the goal was to discriminate between stable and quasi-stable implants; thus the stem-bone system was assumed to be linear in both cases. For that reason, it was decided to study the frequency responses of the system, instead of the harmonic distortion. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The most sensitive parameter to stability was the shift in resonance frequency of the stem-bone system, which was highly correlated with residual micromotion on all four specimens.

  6. Effects of Materials of Cementless Femoral Stem on the Functional Adaptation of Bone

    Institute of Scientific and Technical Information of China (English)

    He Gong; Wei Wu; Juan Fang; Xin Dong; Meisheng Zhao; Tongtong Guo

    2012-01-01

    The objective of this paper is to identify the effects of materials of cementless femoral stem on the functional adaptive behaviors of bone.The remodeling behaviors of a two-dimensional simplified model of cementless hip prosthesis with stiff stem,flexible 'iso-elastic' stem,one-dimensional Functionally Graded Material (FGM) stem and two-dimensional FGM stem for the period of four years after prosthesis replacement were quantified by incorporating the bone remodeling algorithm with finite element analysis.The distributions of bone density,von Mises stress,and interface shear stress were obtained.The results show that two-dimensional FGM stem may produce more mechanical stimuli and more uniform interface shear stress compared with the stems made of other materials,thus the host bone is well preserved.Accordingly,the two-dimensional FGM stem is an appropriate femoral implant from a biomechanical point of view.The numerical simulation in this paper can provide a quantitative computational paradigm for the changes of bone morphology caused by implants,which can help to improve the design of implant to reduce stress shielding and the risk of bone-prosthesis interface failure.

  7. Long-term outcome of a metal-on-polyethylene cementless hip resurfacing.

    Science.gov (United States)

    Tan, Timothy L; Ebramzadeh, Edward; Campbell, Patricia A; Al-Hamad, Mariam; Amstutz, Harlan C

    2014-04-01

    Due to the well-documented problems surrounding metal-on-metal bearings, the use of hip resurfacing has declined. Since the potential benefits of hip resurfacing remain desirable, it may be beneficial to investigate the long-term outcome of hip resurfacings using metal-on-polyethylene in the 1980's. We report the long-term survivorship and modes of failure of a cementless metal-on-polyethylene resurfacing (n = 178) with different porous ingrowth surfaces. While acetabular loosening was absent, a high incidence of femoral failures (femoral loosening = 18.1%, osteolytic neck fracture = 21%) occurred despite using the same ingrowth surface for both components. Ongoing developments using the lessons learned from these previous generation components and utilizing modern low wear materials, e.g., cross-linked polyethylene, may lead to improved implants for future hip resurfacings.

  8. Utilizing of the metallurgical slag for production of cementless concrete mixtures

    Directory of Open Access Journals (Sweden)

    D. Baricová

    2012-10-01

    Full Text Available In process of pig iron, steel and cast iron production besides main product, also secondary products are formed, that have character of secondary raw materials and industrial wastes. The most abundant secondary product originating in the metallurgical process is furnace slag. Total amount of accured slag, also its chemical, mineralogical, physical – chemical properties and similarity with natural stones predestinate its utilisation in different fields of industry. The contribution deals with production of cementless concrete mixtures, where the main parts were formed by blast furnace granulated slag grinded and different gravel slag from blast furnace, oxygen converter and electric arc furnace. As activators of solidification different kinds of water glass were tested.

  9. Total hip arthroplasty using a cylindrical cementless stem in patients with a small physique.

    Science.gov (United States)

    Nakamura, Yoshihide; Mitsui, Hiromasa; Kikuchi, Akira; Toh, Satoshi; Katano, Hiroshi

    2011-01-01

    We performed total hip arthroplasty using an anatomic medullary locking cementless stem for small-physique patients from 1988 to 1995. We conducted a retrospective study of 50 joints in 44 cases, including 40 developmentally dysplastic hips followed for 12 to 20 years (average, 15.1 years). Average height and body weight were 152 cm and 56 kg (5.0 ft and 124 lb), respectively, with an average body mass index of 24.2. Twelve joints (24%) were revised for acetabular-sided failures. Forty-eight stems (96%) showed bone ingrowth fixation, and there were no unstable stems. The simple cylindrical shape of the distal portion of the AML stem was less affected by deformity of the proximal femur of developmental dysplasia of the hip in patients with a small physique, and both clinically and radiologically good results were confirmed at long-term follow-up.

  10. A biodegradable gentamicin-hydroxyapatite-coating for infection prophylaxis in cementless hip prostheses

    Directory of Open Access Journals (Sweden)

    D Neut

    2015-01-01

    Full Text Available A degradable, poly (lactic-co-glycolic acid (PLGA, gentamicin-loaded prophylactic coating for hydroxyapatite (HA-coated cementless hip prostheses is developed with similar antibacterial efficacy as offered by gentamicin-loaded cements for fixing traditional, cemented prostheses in bone. We describe the development pathway, from in vitro investigation of antibiotic release and antibacterial properties of this PLGA-gentamicin-HA-coating in different in vitro models to an evaluation of its efficacy in preventing implant-related infection in rabbits. Bone in-growth in the absence and presence of the coating was investigated in a canine model. The PLGA-gentamicin-HA-coating showed high-burst release, with antibacterial efficacy in agar-assays completely disappearing after 4 days, minimising risk of inducing antibiotic resistance. Gentamicin-sensitive and gentamicin-resistant staphylococci were killed by the antibiotic-loaded coating, in a simulated prosthesis-related interfacial gap. PLGA-gentamicin-HA-coatings prevented growth of bioluminescent staphylococci around a miniature-stem mounted in bacterially contaminated agar, as observed using bio-optical imaging. PLGA-gentamicin-HA-coated pins inserted in bacterially contaminated medullary canals in rabbits caused a statistically significant reduction in infection rates compared to HA-coated pins without gentamicin. Bone ingrowth to PLGA-gentamicin-HA-coated pins, in condylar defects of Beagle dogs was not impaired by the presence of the degradable, gentamicin-loaded coating. In conclusion, the PLGA-gentamicin-HA-coating constitutes an effective strategy for infection prophylaxis in cementless prostheses.

  11. Acoustic pattern evaluation during cementless hip arthroplasty surgery may be a new method for predicting complications

    Science.gov (United States)

    Morohashi, Itaru; Iwase, Hideaki; Kanda, Akio; Sato, Taichi; Homma, Yasuhiro; Mogami, Atsuhiko; Obayashi, Osamu; Kaneko, Kazuo

    2017-01-01

    Background: Although surgeons must perform implantation of the cementless stem during total hip arthroplasty (THA) without complications, assessment is left to the surgeon’s intuitive judgement, which could contain inter/intra-observer bias variety. We therefore asked (1) whether the sound created during the stem implantation could be evaluated objectively and (2) whether those sounds are correlate to the complication specific to the cementless stems. Our hypothesis is that the sounds produced during stem insertion could be quantified and related to the complications. Patients and method: In 71 THAs, we quantified the sound produced during stem insertion and investigated the relationship between these sounds and the occurrence of intraoperative fracture and subsidence. Results: The sound data were divided into two patterns: Patterns A and B. The difference between the peak value (dB) at the most common frequency (near 7 kHz) and the second most common frequency (near 4 kHz) of strikes during the final phase of implantation in Patterns A and B showed a significant difference. Adverse events on intraoperative fracture and subsidence were significantly less common in patients with Pattern A than in those with Pattern B (six of 42 hips with Pattern A and 13 of 29 hips with Pattern B, p = 0.004). Pattern A in predicting a clinical course without those adverse events was 69.2% and the specificity was 68.4%. Positive and negative predictive values were 85.7% and 44.8%, respectively. Conclusion: The sound generated during stem insertion was quantified. Those sound patterns were associated with complications. PMID:28186872

  12. Do Rerevision Rates Differ After First-time Revision of Primary THA With a Cemented and Cementless Femoral Component?

    DEFF Research Database (Denmark)

    Gromov, Kirill; Pedersen, Alma B; Overgaard, Søren

    2015-01-01

    ) and 2 years (range, 0-16 years), respectively. Survival of first revision THA, with second revision of the femur as outcome, was evaluated using hazard ratios (HRs) with 95% confidence interval (CI) adjusting for potential confounding. All patient- and surgery-related data are collected from Danish...... medical databases. Recording of bone defects in the DHR is based on surgeons' intraoperative findings. With the numbers studied, we found no differences in the risk of second revision between the overall cohort between cementless and cemented techniques (HR, 1.32; 95% CI, 0.97-1.80; p = 0.076); however...... for the most likely confounding factors. Our data suggest that increased use of cementless fixation in primary THA may lead to inferior survivorship of first revision THA. Level III, therapeutic study....

  13. Prospective study of the cementless "New Wave" total knee mobile-bearing arthroplasty: 8-year follow-up.

    Science.gov (United States)

    Normand, Xavier; Pinçon, Jean-Louis; Ragot, Jean-Marie; Verdier, Régis; Aslanian, Thierry

    2015-02-01

    One of the main factors affecting the survival of a total knee arthroplasty (TKA) is the fixation method. The constraints placed on the bone-implant interface of a mobile-bearing TKA must be taken in account during the design and evaluation phases. For more than two decades, calcium phosphate ceramics, particularly hydroxyapatitis, have been used in Europe to accelerate the bone integration of cementless implants. A prospective study of patients continuously recruited by three senior surgeons at three French private hospitals has been carried out. There were no exclusion criteria. Eighty-four (84) cementless mobile-bearing total knee prosthesis of the brand "New Wave" were implanted in 74 patients over a 2-year period (2004-2005). Implant survival at 8 years was 95% [with a confidence interval of 95%: 80.2-96.4%] when revision for any cause was defined as the endpoint. Five implants required surgical revision to exchange all or part of the implant: two for aseptic loosening of tibial component, one for osteolysis, one for persistent flessum (30°) and one for tibial periprosthetic fracture. Completely integrated implants and event-free outcomes were recorded in 91.4% of the cases at eight-year follow-up. The Hospital for Special Surgery score significantly improved from 56.8/100 points before the surgery to 83.9/100 points at the last follow-up (p < 0.05). Radiologically, only one patient had radiolucent lines around the tibial and femoral components. This cementless total knee prosthesis yielded good medium-term survival. Cementless arthroplasty can generate solid and durable bone fixation in this total weight-bearing implant, and it seems that the hidroxyapathitis surface in this series stimulate the bone integration at the bone-implant interface.

  14. Formation of highly porous aerosol particles by atmospheric freeze-drying in ice clouds.

    Science.gov (United States)

    Adler, Gabriela; Koop, Thomas; Haspel, Carynelisa; Taraniuk, Ilya; Moise, Tamar; Koren, Ilan; Heiblum, Reuven H; Rudich, Yinon

    2013-12-17

    The cycling of atmospheric aerosols through clouds can change their chemical and physical properties and thus modify how aerosols affect cloud microphysics and, subsequently, precipitation and climate. Current knowledge about aerosol processing by clouds is rather limited to chemical reactions within water droplets in warm low-altitude clouds. However, in cold high-altitude cirrus clouds and anvils of high convective clouds in the tropics and midlatitudes, humidified aerosols freeze to form ice, which upon exposure to subsaturation conditions with respect to ice can sublimate, leaving behind residual modified aerosols. This freeze-drying process can occur in various types of clouds. Here we simulate an atmospheric freeze-drying cycle of aerosols in laboratory experiments using proxies for atmospheric aerosols. We find that aerosols that contain organic material that undergo such a process can form highly porous aerosol particles with a larger diameter and a lower density than the initial homogeneous aerosol. We attribute this morphology change to phase separation upon freezing followed by a glass transition of the organic material that can preserve a porous structure after ice sublimation. A porous structure may explain the previously observed enhancement in ice nucleation efficiency of glassy organic particles. We find that highly porous aerosol particles scatter solar light less efficiently than nonporous aerosol particles. Using a combination of satellite and radiosonde data, we show that highly porous aerosol formation can readily occur in highly convective clouds, which are widespread in the tropics and midlatitudes. These observations may have implications for subsequent cloud formation cycles and aerosol albedo near cloud edges.

  15. Preparation and hydrogen storage capacity of highly porous activated carbon materials derived from polythiophene

    OpenAIRE

    2011-01-01

    [EN] Highly porous carbons have been successfully synthesized by chemical activation of polythiophene with KOH. The activation process was performed under relatively mild activation conditions, i. e., a KOH/polymer weight ratio of 2 and reaction temperatures in the 600–850 °C range. The porous carbons thus obtained possess very large surface areas, up to 3000 m2/g, and pore volumes of up to 1.75 cm3/g. The pore size distribution of these carbons can be tuned via modification of the activation...

  16. Correlation Function Approach for Estimating Thermal Conductivity in Highly Porous Fibrous Materials

    Science.gov (United States)

    Martinez-Garcia, Jorge; Braginsky, Leonid; Shklover, Valery; Lawson, John W.

    2011-01-01

    Heat transport in highly porous fiber networks is analyzed via two-point correlation functions. Fibers are assumed to be long and thin to allow a large number of crossing points per fiber. The network is characterized by three parameters: the fiber aspect ratio, the porosity and the anisotropy of the structure. We show that the effective thermal conductivity of the system can be estimated from knowledge of the porosity and the correlation lengths of the correlation functions obtained from a fiber structure image. As an application, the effects of the fiber aspect ratio and the network anisotropy on the thermal conductivity is studied.

  17. Highly porous thermal protection materials: Modelling and prediction of the methodical experimental errors

    Science.gov (United States)

    Cherepanov, Valery V.; Alifanov, Oleg M.; Morzhukhina, Alena V.; Budnik, Sergey A.

    2016-11-01

    The formation mechanisms and the main factors affecting the systematic error of thermocouples were investigated. According to the results of experimental studies and mathematical modelling it was established that in highly porous heat resistant materials for aerospace application the thermocouple errors are determined by two competing mechanisms provided correlation between the errors and the difference between radiation and conduction heat fluxes. The comparative analysis was carried out and some features of the methodical error formation related to the distances from the heated surface were established.

  18. Titanium Alloys

    Directory of Open Access Journals (Sweden)

    Mark T. Whittaker

    2015-08-01

    Full Text Available Although originally discovered in the 18th century [1], the titanium industry did not experience any significant advancement until the middle of the 20th century through the development of the gas turbine engine [2]. Since then, the aerospace sector has dominated worldwide titanium use with applications in both engines and airframe structures [3]. The highly desirable combination of properties, which include excellent corrosion resistance, favourable strength to weight ratios, and an impressive resistance to fatigue, has led to an extensive range of applications [4], with only high extraction and processing costs still restricting further implementation. [...

  19. Highly porous activated carbons from resource-recovered Leucaena leucocephala wood as capacitive deionization electrodes.

    Science.gov (United States)

    Hou, Chia-Hung; Liu, Nei-Ling; Hsi, Hsing-Cheng

    2015-12-01

    Highly porous activated carbons were resource-recovered from Leucaena leucocephala (Lam.) de Wit. wood through combined chemical and physical activation (i.e., KOH etching followed by CO2 activation). This invasive species, which has severely damaged the ecological economics of Taiwan, was used as the precursor for producing high-quality carbonaceous electrodes for capacitive deionization (CDI). Carbonization and activation conditions strongly influenced the structure of chars and activated carbons. The total surface area and pore volume of activated carbons increased with increasing KOH/char ratio and activation time. Overgasification induced a substantial amount of mesopores in the activated carbons. In addition, the electrochemical properties and CDI electrosorptive performance of the activated carbons were evaluated; cyclic voltammetry and galvanostatic charge/discharge measurements revealed a typical capacitive behavior and electrical double layer formation, confirming ion electrosorption in the porous structure. The activated-carbon electrode, which possessed high surface area and both mesopores and micropores, exhibited improved capacitor characteristics and high electrosorptive performance. Highly porous activated carbons derived from waste L. leucocephala were demonstrated to be suitable CDI electrode materials.

  20. Highly porous, low elastic modulus 316L stainless steel scaffold prepared by selective laser melting.

    Science.gov (United States)

    Čapek, Jaroslav; Machová, Markéta; Fousová, Michaela; Kubásek, Jiří; Vojtěch, Dalibor; Fojt, Jaroslav; Jablonská, Eva; Lipov, Jan; Ruml, Tomáš

    2016-12-01

    Recently, porous metallic materials have been extensively studied as candidates for use in the fabrication of scaffolds and augmentations to repair trabecular bone defects, e.g. in surroundings of joint replacements. Fabricating these complex structures by using common approaches (e.g., casting and machining) is very challenging. Therefore, rapid prototyping techniques, such as selective laser melting (SLM), have been investigated for these applications. In this study, we characterized a highly porous (87 vol.%) 316L stainless steel scaffold prepared by SLM. 316L steel was chosen because it presents a biomaterial still widely used for fabrication of joint replacements and, from the practical point of view, use of the same material for fabrication of an augmentation and a joint replacement is beneficial for corrosion prevention. The results are compared to the reported properties of two representative nonporous 316L stainless steels prepared either by SLM or casting and subsequent hot forging. The microstructural and mechanical properties and the surface chemical composition and interaction with the cells were investigated. The studied material exhibited mechanical properties that were similar to those of trabecular bone (compressive modulus of elasticity ~0.15GPa, compressive yield strength ~3MPa) and cytocompatibility after one day that was similar to that of wrought 316L stainless steel, which is a commonly used biomaterial. Based on the obtained results, SLM is a suitable method for the fabrication of porous 316L stainless steel scaffolds with highly porous structures.

  1. Fabrication of highly porous biodegradable biomimetic nanocomposite as advanced bone tissue scaffold

    Directory of Open Access Journals (Sweden)

    Abdalla Abdal-hay

    2017-02-01

    Full Text Available Development of bioinspired or biomimetic materials is currently a challenge in the field of tissue regeneration. In-situ 3D biomimetic microporous nanocomposite scaffold has been developed using a simple lyophilization post hydrothermal reaction for bone healing applications. The fabricated 3D porous scaffold possesses advantages of good bonelike apatite particles distribution, thermal properties and high porous interconnected network structure. High dispersion bonelike apatite nanoparticles (NPs rapidly nucleated and deposited from surrounding biological minerals within chitosan (CTS matrices using hydrothermal technique. After that, freeze-drying method was applied on the composite solution to form the desired porous 3D architecture. Interestingly, the porosity and pore size of composite scaffold were not significantly affected by the particles size and particles content within the CTS matrix. Our results demonstrated that the compression modulus of porous composite scaffold is twice higher than that of plain CTS scaffold, indicating a maximization of the chemical interaction between polymer matrix and apatite NPs. Cytocompatibility test for MC3T3-E1 pre-osteoblasts cell line using MTT-indirect assay test showed that the fabricated 3D microporous nanocomposite scaffold possesses higher cell proliferation and growth than that of pure CTS scaffold. Collectively, our results suggest that the newly developed highly porous apatite/CTS nanocomposite scaffold as an alternative of hydroxyapatite/CTS scaffold may serve as an excellent porous 3D platform for bone tissue regeneration.

  2. Biomechanical evaluation of adjunctive cerclage wire fixation for the prevention of periprosthetic femur fractures using cementless press-fit total hip replacement.

    Science.gov (United States)

    Christopher, Scott A; Kim, Stanley E; Roe, Simon; Pozzi, Antonio

    2016-08-01

    Periprosthetic femoral fractures are a common complication associated with cementless press-fit total hip arthroplasty. The use of prophylactic cerclage wire fixation has been advocated to reduce this complication. The objective of this study was to evaluate whether a double loop cerclage wire, used as adjunctive fixation, increased the peak torsional load to failure in femora implanted with press-fit cementless stems. Peak torsional load to failure was compared between femora without adjunctive fixation and femora receiving a 1 mm double loop cerclage wire placed proximally to the lesser trochanter. Femora treated with adjunctive cerclage wire fixation failed at 20% greater peak torque (P = 0.0001). In conclusion, a double loop cerclage wire may aid in the prevention of periprosthetic fractures associated with press-fit cementless femoral stems.

  3. PROPERTIES OF HIGHLY POROUS CORDIERITE CERAMIC OBTAINED BY DIRECT FOAMING AND GELCASTING METHOD

    Directory of Open Access Journals (Sweden)

    Ye Li

    2016-05-01

    Full Text Available The highly porous cordierite ceramics were fabricated combining the merits of direct foaming and gelcasting method. The content of gum arabic had a great influence on the foaming capacity and the stability of the wet slurry foam. And the foaming capacity mainly affected the porosity while the stability mainly affected the pore size. The highest porosity of 90% was obtained at 0.4 wt.% gum arabic content and the smallest pore size and the most homogeneous pore distribution were arrived at 1.2 wt.% gum arabic content. As the sintering temperature increased, the porosity and pore size decreased but the uniformity of the pore distribution increased. Moreover, the thermal conductivity was mainly affected not only by the porosity, but also by the sintering degree of the cordierite substrate.

  4. Variational Multiscale Finite Element Method for Flows in Highly Porous Media

    KAUST Repository

    Iliev, O.

    2011-10-01

    We present a two-scale finite element method (FEM) for solving Brinkman\\'s and Darcy\\'s equations. These systems of equations model fluid flows in highly porous and porous media, respectively. The method uses a recently proposed discontinuous Galerkin FEM for Stokes\\' equations by Wang and Ye and the concept of subgrid approximation developed by Arbogast for Darcy\\'s equations. In order to reduce the "resonance error" and to ensure convergence to the global fine solution, the algorithm is put in the framework of alternating Schwarz iterations using subdomains around the coarse-grid boundaries. The discussed algorithms are implemented using the Deal.II finite element library and are tested on a number of model problems. © 2011 Society for Industrial and Applied Mathematics.

  5. Highly Porous Carbon Derived from MOF-5 as a Support of ORR Electrocatalysts for Fuel Cells.

    Science.gov (United States)

    Khan, Inayat Ali; Qian, Yuhong; Badshah, Amin; Nadeem, Muhammad Arif; Zhao, Dan

    2016-07-13

    The development of highly competent electrocatalysts for the sluggish oxygen reduction reaction (ORR) at cathodes of proton-exchange membrane fuel cells (PEMFCs) is extremely important for their long-term operation and wide applications. Herein, we present highly efficient ORR electrocatalysts based on Pt/Ni bimetallic nanoparticles dispersed on highly porous carbon obtained via pyrolysis of a metal-organic framework MOF-5. In comparison to the commercial Pt/C (20%), the electrocatalyst Pt-Ni/PC 950 (15:15%) in this study exhibits a pronounced positive shift of 90 mV in Eonset. In addition, it also demonstrates excellent long-term stability and durability during the 500-cycle continue-oxygen-supply (COS) accelerating durability tests (ADTs). The significantly improved activity and stability of Pt-Ni/PC 950 (15:15%) can be attributed to the Pt electron interaction with Ni and carbon support as has been proved in X-ray and microscopic analysis.

  6. Effect of sintering temperature on structure and properties of highly porous glass-ceramics

    Directory of Open Access Journals (Sweden)

    Artem Iatsenko

    2015-06-01

    Full Text Available Highly porous biomaterials with a structure close to that of cancellous bone have been prepared using biogenic hydroxyapatite and glass of the SiO2-Na2O-CaO system by a replication of the polymer template structure. It has been established that during sintering of the samples the hydroxyapatite decomposes, which involves the formation of glass-ceramics containing phases of renanit NaCaPO4, calcium phosphate silicate Ca5(PO42SiO4, calcium pyrophosphate Ca2P2O7 and impurities of hydroxyapatite Ca5(PO43(OH. Structural characteristics and mechanical properties of the obtained materials are promising for the replacement of defective cancellous bone.

  7. Efficient transparent thin dye solar cells based on highly porous 1D photonic crystals

    Energy Technology Data Exchange (ETDEWEB)

    Colodrero, Silvia; Lopez-Lopez, Carmen; Miguez, Hernan [Instituto de Ciencia de Materiales de Sevilla (CSIC-US), Centro de Investigaciones Cientificas Isla de la Cartuja, C/Americo Vespucio 49, 41092 Sevilla (Spain); Forneli, Amparo; Pelleja, Laia [Institute of Chemical Research of Catalonia (ICIQ) Avda., Paisos Catalans 16, 43007 Tarragona (Spain); Palomares, Emilio [Institute of Chemical Research of Catalonia (ICIQ) Avda., Paisos Catalans 16, 43007 Tarragona (Spain); Institucio Catalana de Recerca i Estudis Avancats (ICREA), Avda. Lluis Companys 23, 08010 Barcelona (Spain)

    2012-03-21

    A working electrode design based on a highly porous 1D photonic crystal structure that opens the path towards high photocurrents in thin, transparent, dye-sensitized solar cells is presented. By enlarging the average pore size with respect to previous photonic crystal designs, the new working electrode not only increases the device photocurrent, as predicted by theoretical models, but also allows the observation of an unprecedented boost of the cell photovoltage, which can be attributed to structural modifications caused during the integration of the photonic crystal. These synergic effects yield conversion efficiencies of around 3.5% by using just 2 {mu}m thick electrodes, with enhancements between 100% and 150% with respect to reference cells of the same thickness. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  8. Metallosis with pseudotumour formation: Long-term complication following cementless total hip replacement in a dog

    Science.gov (United States)

    Volstad, Nicola J.; Schaefer, Susan L.; Snyder, Laura A.; Meinen, Jeffrey B.; Sample, Susannah J.

    2017-01-01

    Summary Case description A 10-year-old female Belgian Teruven dog was presented to our clinic for total hip revision following a diagnosis of implant (cup) failure with metallosis and abdominal pseudotumour formation. The patient had a cementless metal-on-polyethylene total hip replacement performed nine years prior to presentation. Clinical findings The clinical findings, including pseudotumour formation locally and at sites distant from the implant and pain associated with the joint replacement, were similar to those described in human patients with this condition. Histopathological, surgical, and radiographic findings additionally supported the diagnosis of metallosis and pseudotumour formation. Treatment and outcome Distant site pseudo tumours were surgically removed and the total hip replacement was explanted due to poor bone quality. The patient recovered uneventfully and has since resumed normal activity. Conclusion In veterinary patients with metal-on-polyethylene total hip implants, cup failure leading to metallosis and pseudotumour formation should be considered as a potential cause of ipsilateral hindlimb lameness, intra-pelvic abdominal tumours, or a combination of both. These clinical findings may occur years after total hip replacement surgery. PMID:27189390

  9. Primary Stability Recognition of the Newly Designed Cementless Femoral Stem Using Digital Signal Processing

    Science.gov (United States)

    Salleh, Sh-Hussain; Hamedi, Mahyar; Zulkifly, Ahmad Hafiz; Lee, Muhammad Hisyam; Mohd Noor, Alias; Harris, Arief Ruhullah A.; Abdul Majid, Norazman

    2014-01-01

    Stress shielding and micromotion are two major issues which determine the success of newly designed cementless femoral stems. The correlation of experimental validation with finite element analysis (FEA) is commonly used to evaluate the stress distribution and fixation stability of the stem within the femoral canal. This paper focused on the applications of feature extraction and pattern recognition using support vector machine (SVM) to determine the primary stability of the implant. We measured strain with triaxial rosette at the metaphyseal region and micromotion with linear variable direct transducer proximally and distally using composite femora. The root mean squares technique is used to feed the classifier which provides maximum likelihood estimation of amplitude, and radial basis function is used as the kernel parameter which mapped the datasets into separable hyperplanes. The results showed 100% pattern recognition accuracy using SVM for both strain and micromotion. This indicates that DSP could be applied in determining the femoral stem primary stability with high pattern recognition accuracy in biomechanical testing. PMID:24800230

  10. Fabrication of low-cost, cementless femoral stem 316L stainless steel using investment casting technique.

    Science.gov (United States)

    Baharuddin, Mohd Yusof; Salleh, Sh-Hussain; Suhasril, Andril Arafat; Zulkifly, Ahmad Hafiz; Lee, Muhammad Hisyam; Omar, Mohd Afian; Abd Kader, Ab Saman; Mohd Noor, Alias; A Harris, Arief Ruhullah; Abdul Majid, Norazman

    2014-07-01

    Total hip arthroplasty is a flourishing orthopedic surgery, generating billions of dollars of revenue. The cost associated with the fabrication of implants has been increasing year by year, and this phenomenon has burdened the patient with extra charges. Consequently, this study will focus on designing an accurate implant via implementing the reverse engineering of three-dimensional morphological study based on a particular population. By using finite element analysis, this study will assist to predict the outcome and could become a useful tool for preclinical testing of newly designed implants. A prototype is then fabricated using 316L stainless steel by applying investment casting techniques that reduce manufacturing cost without jeopardizing implant quality. The finite element analysis showed that the maximum von Mises stress was 66.88 MPa proximally with a safety factor of 2.39 against endosteal fracture, and micromotion was 4.73 μm, which promotes osseointegration. This method offers a fabrication process of cementless femoral stems with lower cost, subsequently helping patients, particularly those from nondeveloped countries.

  11. Early results of the use of oblong S-ROM cementless acetabular component

    Directory of Open Access Journals (Sweden)

    Popović Zoran

    2003-01-01

    Full Text Available Massive deficiency of acetabular bone stock is a challenging problem in the increasing number of patients who need a revision of the failed hip arthroplasty. Oblong acetabular cup has been presented as an alternative reconstruction technique for hips with extensive acetabular bone loss. The aim of this study was to present our results with the use of a bilobed acetabular component inserted during revisional surgery, to define indications, and to introduce this method into our orthopaedic practice. Seven patients underwent revisional hip arthroplasty with a cementless oblong acetabular component between September 2000 and June 2002. Six patients underwent revisional hip arthroplasty, and in one primary hip arthroplasty by oblong acetabular component was performed because of bone defect of acetabulum after gunshot fracture. The average follow up was thirteen months. Radiographic analysis in all patients demonstrated stable bone incorporated acetabular component with the restored hip. All the patients walked with full weight bearing and were without pain. On the basis of our experience we find this method statisfactory in certain types of bone defefects of acetabulum, and that it provides stable reconstruction of acetabulum with the correction of hip joint.

  12. Protein growth factors loaded highly porous chitosan scaffold: A comparison of bone healing properties

    Energy Technology Data Exchange (ETDEWEB)

    Nandi, Samit K., E-mail: samitnandi1967@gmail.com [Department of Veterinary Surgery and Radiology, West Bengal University of Animal and Fishery Sciences, Kolkata (India); Kundu, Biswanath, E-mail: biswa_kundu@rediffmail.com [Bioceramics and Coating Division, CSIR—Central Glass and Ceramic Research Institute, Kolkata (India); Basu, Debabrata [Bioceramics and Coating Division, CSIR—Central Glass and Ceramic Research Institute, Kolkata (India)

    2013-04-01

    Present study aimed to investigate and compare effectiveness of porous chitosan alone and in combination with insulin like growth factor-1 (IGF-1) and bone morphogenetic protein-2 (BMP-2) in bone healing. Highly porous (85 ± 2%) with wide distribution of macroporous (70–900 μm) chitosan scaffolds were fabricated as bone substitutes by employing a simple liquid hardening method using 2% (w/v) chitosan suspension. IGF-1 and BMP-2 were infiltrated using vacuum infiltration with freeze drying method. Adsorption efficiency was found to be 87 ± 2 and 90 ± 2% for BMP-2 and IGF-1 respectively. After thorough material characterization (pore details, FTIR and SEM), samples were used for subsequent in vivo animal trial. Eighteen rabbit models were used to evaluate and compare control (chitosan) (group A), chitosan with IGF-1 (group B) and chitosan with BMP-2 (group C) in the repair of critical size bone defect in tibia. Radiologically, there was evidence of radiodensity in defect area from 60th day (initiated on 30th day) in groups B and C as compared to group A and attaining nearly bony density in most of the part at day 90. Histological results depicted well developed osteoblastic proliferation around haversian canal along with proliferating fibroblast, vascularization and reticular network which was more pronounced in group B followed by groups C and A. Fluorochrome labeling and SEM studies in all groups showed similar outcome. Hence, porous chitosan alone and in combination with growth factors (GFs) can be successfully used for bone defect healing with slight advantage of IGF-1 in chitosan samples. - Highlights: ► Fabrication and characterization of porous chitosan with or without IGF-1 and BMP-2 ► Highly porous growth factor loaded chitosan studied in animal subjects for 3 months ► Parameters studied: histopathology, radiology and fluorochrome labeling ► IGF-1 loaded porous chitosan found to be very effective for bone defect healing.

  13. A multicenter approach evaluating the impact of vitamin e-blended polyethylene in cementless total hip replacement.

    Science.gov (United States)

    Jäger, Marcus; van Wasen, Andrea; Warwas, Sebastian; Landgraeber, Stefan; Haversath, Marcel; Group, Vitas

    2014-04-22

    Since polyethylene is one of the most frequently used biomaterials as a liner in total hip arthroplasty, strong efforts have been made to improve design and material properties over the last 50 years. Antioxidants seems to be a promising alternative to further increase durability and reduce polyethylene wear in long term. As of yet, only in vitro results are available. While they are promising, there is yet no clinical evidence that the new material shows these advantages in vivo. To answer the question if vitamin-E enhanced ultra-high molecular weight polyethylene (UHMWPE) is able to improve long-term survivorship of cementless total hip arthroplasty we initiated a randomized long-term multicenter trial. Designed as a superiority study, the oxidation index assessed in retrieval analyses of explanted liners was chosen as primary parameter. Radiographic results (wear rate, osteolysis, radiolucency) and functional outcome (Harris Hip Scores, University of California-Los Angeles, Hip Disability and Osteoarthritis Outcome Score, Visual Analogue Scale) will serve as secondary parameters. Patients with the indication for a cementless total hip arthroplasty will be asked to participate in the study and will be randomized to either receive a standard hip replacement with a highly cross-linked UHMWPE-X liner or a highly cross-linked vitamin-E supplemented UHMWPE-XE liner. The follow-up will be 15 years, with evaluation after 5, 10 and 15 years. The controlled randomized study has been designed to determine if Vitamin-E supplemented highly cross-linked polyethylene liners are superior to standard XLPE liners in cementless total hip arthroplasty. While several studies have been started to evaluate the influence of vitamin-E, most of them evaluate wear rates and functional results. The approach used for this multicenter study, to analyze the oxidation status of retrieved implants, should make it possible to directly evaluate the ageing process and development of the implant

  14. A multicenter approach evaluating the impact of vitamin E-blended polyethylene in cementless total hip replacement

    Directory of Open Access Journals (Sweden)

    Marcus Jäger

    2014-04-01

    Full Text Available Since polyethylene is one of the most frequently used biomaterials as a liner in total hip arthroplasty, strong efforts have been made to improve design and material properties over the last 50 years. Antioxidants seems to be a promising alternative to further increase durability and reduce polyethylene wear in long term. As of yet, only in vitro results are available. While they are promising, there is yet no clinical evidence that the new material shows these advantages in vivo. To answer the question if vitamin-E enhanced ultra-high molecular weight polyethylene (UHMWPE is able to improve long-term survivorship of cementless total hip arthroplasty we initiated a randomized long-term multicenter trial. Designed as a superiority study, the oxidation index assessed in retrieval analyses of explanted liners was chosen as primary parameter. Radiographic results (wear rate, osteolysis, radiolucency and functional outcome (Harris Hip Scores, University of California-Los Angeles, Hip Disability and Osteoarthritis Outcome Score, Visual Analogue Scale will serve as secondary parameters. Patients with the indication for a cementless total hip arthroplasty will be asked to participate in the study and will be randomized to either receive a standard hip replacement with a highly cross-linked UHMWPE-X liner or a highly cross-linked vitamin-E supplemented UHMWPE-XE liner. The follow-up will be 15 years, with evaluation after 5, 10 and 15 years. The controlled randomized study has been designed to determine if Vitamin-E supplemented highly cross-linked polyethylene liners are superior to standard XLPE liners in cementless total hip arthroplasty. While several studies have been started to evaluate the influence of vitamin-E, most of them evaluate wear rates and functional results. The approach used for this multicenter study, to analyze the oxidation status of retrieved implants, should make it possible to directly evaluate the ageing process and development

  15. New titanium and titanium/hydroxyapatite coatings on ultra-high-molecular-weight polyethylene-in vitro osteoblastic performance

    Energy Technology Data Exchange (ETDEWEB)

    Silva, M A; Lopes, M A; Santos, J D; Fernandes, M H [Department of Metallurgical and Materials Engineering, Materials Section-Faculty of Engineering, University of Porto (Portugal); Gomes, P S [Laboratory of Pharmacology and Cellular Biocompatibility-Faculty of Dental Medicine, University of Porto (Portugal); Vila, M; Silva, R F, E-mail: mhfernandes@fmd.up.p [Department of Ceramics and Glass Engineering, University of Aveiro, CICECO (Portugal)

    2010-06-15

    The development of optimized hip joint materials is one of the most challenging opportunities in prosthetic technologies. In current approaches, ultra-high-molecular-weight polyethylene (UHMWPE) has been a favorite material for the acetabular component and, regarding the cementless technique, several coating options may be considered to contain and stabilize bearing surfaces and establish an improved interface with bone. In this work, newly developed constructs of UHMWPE coated with either commercially pure titanium (cpTi-UHMWPE), by DC magnetron sputtering, or with commercially pure titanium and hydroxyapatite (cpTi/HA-UHMWPE), by DC/RF magnetron co-sputtering, have been prepared and biologically characterized with human bone marrow-derived osteoblastic cultures. The cpTi-UHMWPE samples allowed a high cell growth and the expression of the complete osteoblastic phenotype, with high alkaline phosphatase activity, expression of osteogenic-associated genes and evident cell-mediated mineralization of the extracellular matrix. In comparison, the cpTi/HA-UHMWPE samples reported lower cell proliferation but earlier cell-mediated matrix mineralization. Accordingly, these newly developed systems may be suitable candidates to improve the osteointegration process in arthroplastic devices; nevertheless, further biological evaluation should be conducted.

  16. Total hip arthroplasty with cementless cups and femoral head autografts for patients with hip dysplasia and osteoarthritis

    Institute of Scientific and Technical Information of China (English)

    吴立东; 金礼斌; 严世贵; 杨泉森; 戴雪松; 王祥华

    2004-01-01

    Objective:To evaluate the outcome of total hip arthroplasty (THA) with cementless cups and femoral head autografts for patients with hip dysplasia and osteoarthritis.Methods: Between 1995 and 2002, we implanted 23cementless cups and femoral head autografts in 20 patients with hip dysplasia and osteoarthritis. In this study, a retrospective study was made on 21 hips in 20 patients (18females and 2 males, aged 50 years on an average) with developmental hip dysplasia treated by THA with acementless cup and femoral head autograft. The acetabular cup was placed at the level of the true acetabuinm and all the patients required autogenous femoral head grafts due to acetabular deficiency. The average rate of the acetabular cup covered by the femoral head autograft was 31%(ranging from 10% to 45%). Eight hips had less than 25%cup coverage and thirteen between 25% and 50%. The average follow-up period was 4.7 years (range, 1-8 years).The replacing outcome was evaluated by modified Harris hip score. Preoperative and follow-up radiographs were made.Results: All the autografts were united to the host bones. No autograft was collapsed or no component from the hip was loosed in all the patients. According to the modified Harris hip score, the average hip score increased from 46 before operation to 89 at the final review. Before operation, the leg-length discrepancy was greater than 2 cm in all the patients except one with bilateral hip dysplasia.After operation, only 2 out of 20 patients had a leg-length discrepancy greater than 1 cm. Three hips showed minor bone resorption in the lateral portion of the graft, which did not support the cup. Three hips developed Grade 1Brooker heterotopic ossification and one developed Grade 2.Conclusions: THA with a cementless cup and a femoral head autograft for patients with osteoarthritis resulted from hip dysplasia can result in favorable outcomes. This method can provide reliable acetabular fixation and restore the acetabular bone stock in

  17. Heat and Mass Transfer in a High-Porous Low-Temperature Thermal Insulation in Real Operating Conditions

    Directory of Open Access Journals (Sweden)

    Polovnikov Vyacheslav Yu.

    2015-01-01

    Full Text Available The results of numerical simulation of heat and mass transfer in a high-porous low-temperature insulation in conditions of insulation freezing, a moisture migration to the front of phase transition and a condensation forming on an outer contour of interaction were obtained. Values of heat leakage were established.

  18. Expanded organic building units for the construction of highly porous metal-organic frameworks.

    Science.gov (United States)

    Kong, Guo-Qiang; Han, Zhi-Da; He, Yabing; Ou, Sha; Zhou, Wei; Yildirim, Taner; Krishna, Rajamani; Zou, Chao; Chen, Banglin; Wu, Chuan-De

    2013-10-25

    Two new organic building units that contain dicarboxylate sites for their self-assembly with paddlewheel [Cu2(CO2)4] units have been successfully developed to construct two isoreticular porous metal-organic frameworks (MOFs), ZJU-35 and ZJU-36, which have the same tbo topologies (Reticular Chemistry Structure Resource (RCSR) symbol) as HKUST-1. Because the organic linkers in ZJU-35 and ZJU-36 are systematically enlarged, the pores in these two new porous MOFs vary from 10.8 Å in HKUST-1 to 14.4 Å in ZJU-35 and 16.5 Å in ZJU-36, thus leading to their higher porosities with Brunauer-Emmett-Teller (BET) surface areas of 2899 and 4014 m(2) g(-1) for ZJU-35 and ZJU-36, respectively. High-pressure gas-sorption isotherms indicate that both ZJU-35 and ZJU-36 can take up large amounts of CH4 and CO2, and are among the few porous MOFs with the highest volumetric storage of CH4 under 60 bar and CO2 under 30 bar at room temperature. Their potential for high-pressure swing adsorption (PSA) hydrogen purification was also preliminarily examined and compared with several reported MOFs, thus indicating the potential of ZJU-35 and ZJU-36 for this important application. Studies show that most of the highly porous MOFs that can volumetrically take up the greatest amount of CH4 under 60 bar and CO2 under 30 bar at room temperature are those self-assembled from organic tetra- and hexacarboxylates that contain m-benzenedicarboxylate units with the [Cu2(CO2)4] units, because this series of MOFs can have balanced porosities, suitable pores, and framework densities to optimize their volumetric gas storage. The realization of the two new organic building units for their construction of highly porous MOFs through their self-assembly with [Cu2(CO2)4] units has provided great promise for the exploration of a large number of new tetra- and hexacarboxylate organic linkers based on these new organic building units in which different aromatic backbones can be readily incorporated

  19. The dimensional accuracy of preparation of femoral cavity in cementless total hip arthroplasty

    Institute of Scientific and Technical Information of China (English)

    WU Li-dong (吴立东); HAHNE H.J.; HASSENPFLUG J.

    2004-01-01

    Objective: To observe the accuracy of femoral preparation and the position of the cementless prosthesis in femoral cavity, and to compare the results between the computer-assisted surgical group (CASPAR) and the conventional group. Methods: Ten femoral components were implanted either manually or by CASPAR in cadaver femurs. The specimens were cut to 3 mm thick slices. Microradiograms of every slice were sent to a computer for analysis with special software (IDL). The gaps and the medullary cavities between component and bone, the direct bone contact area of the implant surface,the gap width and the percentage of gap and bone contact area were measured in every slice. Results: In the proximal implant coated with HA of the CASPAR group, the average percentage of bone contact reached 93.2% (ranging from 87.6% to 99.7%); the average gap percentage was 2.9% (ranging from 0.3% to 7.8%); the maximum gap width was 0.81 mm and the average gap width was only 0.20 mm. While in the conventional group, the average percentage of bone contact reached 60.1% (ranging from 49.2% to 70.4%); the average gap percentage was 32.8% (ranging from 25.1% to 39.9%); the maximum gap width was 2.97 mm and the average gap width was 0.77 mm. The average gap around the implant in the CASPAR group was only 9% of that in the manual group; the maximum and average gap widths were only about 26% of those in the manual group. On the other hand, the CASPAR group showed 33% higher bone contact than the manual group. Conclusion: With the use of robotics-assisted system, significant progress can be achieved for femoral preparation in total hip arthroplasty.

  20. The dimensional accuracy of preparation of femoral cavity in cementless total hip arthroplasty

    Institute of Scientific and Technical Information of China (English)

    吴立东; HAHNEH.J.; HASSENPFLUGJ.

    2004-01-01

    Objective: To observe the accuracy of femoral preparation and the position of the cementless prosthesis in femoral cavity, and to compare the results between the computer-assisted surgical group (CASPAR) and the conventional group. Methods: Ten femoral components were implanted either manually or by CASPAR in cadaver femurs. The specimens were cut to 3mm thick slices. Microradiograms of every slice were sent to a computer for analysis with special software (IDL). The gaps and the medullary cavities between component and bone, the direct bone contact area of the implant surface, the gap width and the percentage of gap and bone contact area were measured in every slice. Results: In the proximal implant coated with HA of the CASPAR group, the average percentage of bone contact reached 93.2% (ranging from 87.6% to 99.7%); the average gap percentage was 2.9% (ranging from 0.3% to 7.8%); the maximum gap width was 0.81mm and the average gap width was only 0.20mm. While in the conventional group, the average percentage of bone contact reached 60.1% (ranging from 49.2% to 70.4%); the average gap percentage was 32.8% (ranging from 25.1% to 39.9%); the maximum gap width was 2.97mm and the average gap width was 0.77mm. The average gap around the implant in the CASPAR group was only 9% of that in the manual group; the maximum and average gap widths were only about 26% of those in the manual group. On the other hand, the CASPAR group showed 33% higher bone contact than the manual group. Conclusion: With the use of robotics-assisted system, significant progress can be achieved for femoral preparation in total hip arthroplasty.

  1. A Facile Synthesis of Nitrogen-Doped Highly Porous Carbon Nanoplatelets: Efficient Catalysts for Oxygen Electroreduction

    Science.gov (United States)

    Zhang, Yaqing; Zhang, Xianlei; Ma, Xiuxiu; Guo, Wenhui; Wang, Chunchi; Asefa, Tewodros; He, Xingquan

    2017-01-01

    The oxygen reduction reaction (ORR) is of great importance for various renewable energy conversion technologies such as fuel cells and metal-air batteries. Heteroatom-doped carbon nanomaterials have proven to be robust metal-free electrocatalysts for ORR in the above-mentioned energy devices. Herein, we demonstrate the synthesis of novel highly porous N-doped carbon nanoplatelets (N-HPCNPs) derived from oatmeal (or a biological material) and we show the materials’ high-efficiency as electrocatalyst for ORR. The obtained N-HPCNPs hybrid materials exhibit superior electrocatalytic activities towards ORR, besides excellent stability and good methanol tolerance in both basic and acidic electrolytes. The unique nanoarchitectures with rich micropores and mesopores, as well as the high surface area-to-volume ratios, present in the materials significantly increase the density of accessible catalytically active sites in them and facilitate the transport of electrons and electrolyte within the materials. Consequently, the N-HPCNPs catalysts hold a great potential to serve as low-cost and highly efficient cathode materials in direct methanol fuel cells (DMFCs). PMID:28240234

  2. A Facile Synthesis of Nitrogen-Doped Highly Porous Carbon Nanoplatelets: Efficient Catalysts for Oxygen Electroreduction.

    Science.gov (United States)

    Zhang, Yaqing; Zhang, Xianlei; Ma, Xiuxiu; Guo, Wenhui; Wang, Chunchi; Asefa, Tewodros; He, Xingquan

    2017-02-27

    The oxygen reduction reaction (ORR) is of great importance for various renewable energy conversion technologies such as fuel cells and metal-air batteries. Heteroatom-doped carbon nanomaterials have proven to be robust metal-free electrocatalysts for ORR in the above-mentioned energy devices. Herein, we demonstrate the synthesis of novel highly porous N-doped carbon nanoplatelets (N-HPCNPs) derived from oatmeal (or a biological material) and we show the materials' high-efficiency as electrocatalyst for ORR. The obtained N-HPCNPs hybrid materials exhibit superior electrocatalytic activities towards ORR, besides excellent stability and good methanol tolerance in both basic and acidic electrolytes. The unique nanoarchitectures with rich micropores and mesopores, as well as the high surface area-to-volume ratios, present in the materials significantly increase the density of accessible catalytically active sites in them and facilitate the transport of electrons and electrolyte within the materials. Consequently, the N-HPCNPs catalysts hold a great potential to serve as low-cost and highly efficient cathode materials in direct methanol fuel cells (DMFCs).

  3. Structure of a designed protein cage that self-assembles into a highly porous cube

    Science.gov (United States)

    Lai, Yen-Ting; Reading, Eamonn; Hura, Greg L.; Tsai, Kuang-Lei; Laganowsky, Arthur; Asturias, Francisco J.; Tainer, John A.; Robinson, Carol V.; Yeates, Todd O.

    2014-12-01

    Natural proteins can be versatile building blocks for multimeric, self-assembling structures. Yet, creating protein-based assemblies with specific geometries and chemical properties remains challenging. Highly porous materials represent particularly interesting targets for designed assembly. Here, we utilize a strategy of fusing two natural protein oligomers using a continuous alpha-helical linker to design a novel protein that self assembles into a 750 kDa, 225 Å diameter, cube-shaped cage with large openings into a 130 Å diameter inner cavity. A crystal structure of the cage showed atomic-level agreement with the designed model, while electron microscopy, native mass spectrometry and small angle X-ray scattering revealed alternative assembly forms in solution. These studies show that accurate design of large porous assemblies with specific shapes is feasible, while further specificity improvements will probably require limiting flexibility to select against alternative forms. These results provide a foundation for the design of advanced materials with applications in bionanotechnology, nanomedicine and material sciences.

  4. Highly porous polymer-derived wollastonite-hydroxycarbonate apatite ceramics for bone regeneration.

    Science.gov (United States)

    Fiocco, L; Li, S; Bernardo, E; Stevens, M M; Jones, J R

    2016-04-12

    A novel strategy was employed to synthesize highly porous wollastonite-hydroxycarbonate apatite ceramic scaffolds for bone regeneration. A commercial liquid preceramic polymer filled with micro-CaCO3 powders was foamed at low temperature (at 350 °C), using the decomposition of a hydrazine additive, and then converted into ceramic by a treatment at 700 °C. Hydroxycarbonate apatite was later developed by a phosphatization treatment of ceramized foams, in a P-rich solution, while wollastonite was obtained by a second firing, at 900 °C. The effectiveness of the method was proven by x-ray diffraction analysis, showing the presence of the two expected crystalline phases. Porosity, interconnect size distribution and mechanical strength were in the range that is thought to be suitable for bone regeneration in non-load bearing sites (compressive strength ≈ 3 MPa, porosity ≈ 90%, modal interconnect diameter ≈ 130-160 μm). In addition, bioactivity and ion release rate were assessed in simulated body fluid (SBF). MC3T3 osteoblast precursor cells were able to colonize the material in vitro through the pore architecture and expressed osteogenic markers.

  5. Preparation and optimization of glyceryl behenate-based highly porous pellets containing cilostazol.

    Science.gov (United States)

    Hwang, Kyu-Mok; Byun, Woojin; Cho, Cheol-Hee; Park, Eun-Seok

    2016-11-03

    The aim of this study was to prepare a highly porous multiparticulate dosage form containing cilostazol for gastroretentive drug delivery. The floating pellets were prepared with glyceryl behenate as a matrix former and camphor as a sublimating agent by extrusion/spheronization and sublimation under vacuum. Granules prepared with sublimation at 60 °C displayed a slower dissolution rate and smoother surface morphology than those prepared at lower temperatures. This was unexpected as the reported melting point of glyceryl behenate is higher than 69 °C. The DSC study revealed that melting began at a lower temperature owing to the multicomponent property of glyceryl behenate, which led to a sintering effect. The prepared pellets were spherical with unimodal size distribution. They also had porous structures with increased porosity, which led to immediate buoyancy. As cilostazol is a hydrophobic drug that has an erosion-based release mechanism, drug release profile was highly correlated with the percentage of disintegrated pellets. Various excipients were added to the glyceryl behenate-based formulation to increase the floating duration. When hydroxyethyl cellulose was added to the glyceryl behenate-based pellets, acceptable dissolution rate and buoyancy were acquired. This system could potentially be used for gastroretentive delivery of various hydrophobic drugs, which was generally considered difficult.

  6. Highly porous organic polymers bearing tertiary amine group and their exceptionally high CO2 uptake capacities

    Science.gov (United States)

    Gomes, Ruth; Bhaumik, Asim

    2015-02-01

    We report a very simple and unique strategy for synthesis of a tertiary amine functionalized high surface area porous organic polymer (POP) PDVTA-1 through the co-polymerization of monomers divinylbenzene (DVB) and triallylamine (TAA) under solvothermal reaction conditions. Two different PDVTA-1 samples have been synthesized by varying the molar ratio of the monomers. The porous polymeric materials have been thoroughly characterized by solid state 13C CP MAS-NMR, FT-IR and UV-vis spectroscopy, N2 sorption, HR TEM and FE SEM to understand its chemical environment, nanostructure, bonding, morphology and related surface properties. PDVTA-1 with higher amine content (DVB/TAA=4.0) showed exceptionally high CO2 uptake capacity of 85.8 wt% (19.5 mmol g-1) at 273 K and 43.69 wt% (9.93 mmol g-1) at 298 K under 3 bar pressure, whereas relatively low amine loaded material (DVB/TAA=7.0) shows uptake capacity of 59.2 wt% (13.45 mmol g-1) at 273 K and 34.36 wt% (7.81 mmol g-1) at 298 K. Highly porous nanostructure together with very high surface area and basicity at the surface due to the presence of abundant basic tertiary amine N-sites in the framework of PDVTA-1 could be responsible for very high CO2 adsorption.

  7. Highly porous polytriazole ion exchange membranes cast from solutions in non-toxic cosolvents

    KAUST Repository

    Chisca, Stefan

    2017-04-04

    The development of highly functionalized porous materials for protein separation is important for biotech processes. We report the preparation of highly porous polytriazole with sulfonic acid functionalization. The resulting ion exchange membranes are selective for protein adsorption. The starting material was a hydroxyl-functionalized polytriazole, which is an advantageous platform for further modification. The polymer was dissolved in a mixture of 1-ethyl-3-methylimidazolium acetate ([C2mim]OAc) and dimethyl carbonate (DMC), which can be both considered green solvents. The polymer solubilization was only possible due to an interesting effect of cosolvency, which is discussed, based in phase diagrams. Membranes were prepared by solution casting, followed by immersion in a non-solvent bath. We then grafted sulfone groups on the membranes, by reacting the hydroxyl groups with 1,3-propane sultone and 1,4-butane sultone. Lysozyme adsorption was successfully evaluated. Membranes modified with 1,4-butane sultone adsorbed more protein than those with 1,3-propane sultone.

  8. CHARACTERIZATION OF HIGHLY POROUS 63S BIOACTIVE GLASS SCAFFOLDS FABRICATED BY TWO FOAMING METHODS

    Directory of Open Access Journals (Sweden)

    Seyed Mehdi Mirhadi

    2015-09-01

    Full Text Available Resorbable 3D macroporous nanostructure 63S bioactive glass scaffolds were fabricated using the two methods of direct foaming of bioactive glass sol and foaming glass slurry for tissue engineering applications. The scaffolds contained an interconnected pore network with macropore sizes in the range of 100 - 400 μm, which provided the potential for tissue ingrowth and vascularization in the human body. The mean values of compressive strength were in the ranges of 0.53 - 0.68 MPa and 0.8 - 0.92 MPa, respectively, for the scaffolds prepared by the first and second methods. The mean values of total and interconnected porosities were in the ranges of 88 - 93 % and 76 - 86 %, respectively. The highly porous and nanosized structure gave rise to a high specific surface area in the scaffolds which stimulated mineralization in the surrounding bones by enhancing bioreactions and leaching of ions from the surface, which facilitate bone repair and fixation. Finally, it was observed that the prepared scaffolds could satisfy the criteria of an ideal scaffold for tissue engineering applications.

  9. Highly porous activated carbons prepared from carbon rich Mongolian anthracite by direct NaOH activation

    Science.gov (United States)

    Byamba-Ochir, Narandalai; Shim, Wang Geun; Balathanigaimani, M. S.; Moon, Hee

    2016-08-01

    Highly porous activated carbons (ACs) were prepared from Mongolian raw anthracite (MRA) using sodium hydroxide as an activation agent by varying the mass ratio (powdered MRA/NaOH) as well as the mixing method of chemical agent and powdered MRA. The specific BET surface area and total pore volume of the prepared MRA-based activated carbons (MACs) are in the range of 816-2063 m2/g and of 0.55-1.61 cm3/g, respectively. The pore size distribution of MACs show that most of the pores are in the range from large micropores to small mesopores and their distribution can be controlled by the mass ratio and mixing method of the activating agent. As expected from the intrinsic property of the MRA, the highly graphitic surface morphology of prepared carbons was confirmed from Raman spectra and transmission electron microscopy (TEM) studies. Furthermore the FTIR and XPS results reveal that the preparation of MACs with hydrophobic in nature is highly possible by controlling the mixing conditions of activating agent and powdered MRA. Based on all the results, it is suggested that the prepared MACs could be used for many specific applications, requiring high surface area, optimal pore size distribution, proper surface hydrophobicity as well as strong physical strength.

  10. A randomised controlled trial of cemented and cementless femoral components for metal-on-metal hip resurfacing: a bone mineral density study.

    Science.gov (United States)

    Tice, A; Kim, P; Dinh, L; Ryu, J J; Beaulé, P E

    2015-12-01

    The primary purpose of this study of metal-on-metal (MoM) hip resurfacing was to compare the effect of using a cementless or cemented femoral component on the subsequent bone mineral density (BMD) of the femoral neck. This was a single-centre, prospective, double-blinded control trial which randomised 120 patients (105 men and 15 women) with a mean age of 49.4 years (21 to 68) to receive either a cemented or cementless femoral component. Follow-up was to two years. Outcome measures included total and six-point region-of-interest BMD of the femoral neck, radiological measurements of acetabular inclination, neck-shaft and stem-shaft angles, and functional outcome scores including the Harris hip score, the Western Ontario and McMaster Universities Osteoarthritis Index and the University of California at Los Angeles activity scale. In total, 17 patients were lost to follow-up leaving 103 patients at two years. There were no revisions in the cementless group and three revisions (5%) in the cemented group (two because of hip pain and one for pseudotumour). The total BMD was significantly higher in the cementless group at six months (p < 0.001) and one year (p = 0.01) than in the cemented group, although there was a loss of statistical significance in the difference at two years (p = 0.155). All patient outcomes improved significantly: there were no significant differences between the two groups. The results show better preservation of femoral neck BMD with a cementless femoral component after two years of follow-up. Further investigation is needed to establish whether this translates into improved survivorship.

  11. Impact experiments of exotic dust grain capture by highly porous primitive bodies

    Science.gov (United States)

    Okamoto, Takaya; Nakamura, Akiko M.; Hasegawa, Sunao; Kurosawa, Kosuke; Ikezaki, Katsutoshi; Tsuchiyama, Akira

    2013-05-01

    Small primitive bodies were presumably highly porous when they formed and some still have low densities that are indicative of a high pore content. Therefore, after their formation, interplanetary dust impacting on their surface may have been captured because of their porous structure. The mechanism of dust penetration is thus of importance to understand the evolution of small bodies and the origin of their internal dust particles. Impact experiments of sintered glass-bead targets characterized by 80%, 87%, and 94% bulk porosity were conducted using metal and basalt projectiles at impact velocities ranging from 1.6 to 7.2 km s-1. Track morphology and penetration processes were analyzed using both X-ray tomography and a flash X-ray system. Two types of track were observed, as previously also found in the Stardust aerogel: a thin and long track (carrot-shaped track), and a "bulb" with tails (bulb-shaped track). The track shape changed with initial dynamic pressure. We found that the transition between "carrot" and "bulb" occurred at a pressure of roughly 20 times the projectile's tensile strength. The deceleration process of projectiles without severe deformation and fragmentation was reproduced by a drag equation composed of an inertia drag that was proportional to the square of the projectile's velocity and a constant drag proportional to the target's compressive strength. We applied this deceleration equation to silicate dust penetrating into hypothetical porous icy bodies which were homogeneous on much smaller scales than the impacting dust particles. The penetration depth was approximately 100 times the projectile diameter for the bodies with 90% porosity.

  12. Preparation of highly porous gastroretentive metformin tablets using a sublimation method.

    Science.gov (United States)

    Oh, Tack-Oon; Kim, Ju-Young; Ha, Jung-Myung; Chi, Sang-Cheol; Rhee, Yun-Seok; Park, Chun-Woong; Park, Eun-Seok

    2013-04-01

    The present investigation is aimed to formulate floating gastroretentive tablets containing metformin using a sublimation material. In this study, the release of the drug from a matrix tablet was highly dependent on the polymer concentrations. In all formulations, initial rapid drug release was observed, possibly due to the properties of the drug and polymer. The effect of the amount of PEO on swelling and eroding of the tablets was determined. The water-uptake and erosion behavior of the gastroretentive (GR) tablets were highly dependent on the amount of PEO. The water-uptake increased with increasing PEO concentration in the tablet matrix. The weight loss from tablets decreased with increasing amounts of PEO. Camphor was used as the sublimation material to prepare GR tablets that are low-density and easily floatable. Camphor was changed to pores in the tablet during the sublimation process. SEM revealed that the GR tablets have a highly porous morphology. Floating properties of tablets and tablet density were affected by the sublimation of camphor. Prepared floating gastroretentive tablets floated for over 24 h and had no floating lag time. However, as the amount of camphor in the tablet matrix increased, the crushing strength of the tablet decreased after sublimation. Release profiles of the drug from the GR tablets were not affected by tablet density or porosity. In pharmacokinetic studies, the mean plasma concentration of the GR tablets after oral administration was greater than the concentration of glucophase XR. Also, the mean AUC(0-∞) values for the GR tablets were significantly greater than the plasma concentrations of glucophase XR.

  13. Titanium and titanium alloys fundamentals and applications

    CERN Document Server

    Peters, Manfred

    2003-01-01

    This handbook is an excellent reference for materials scientists and engineers needing to gain more knowledge about these engineering materials. Following introductory chapters on the fundamental materials properties of titanium, readers will find comprehensive descriptions of the development, processing and properties of modern titanium alloys. There then follows detailed discussion of the applications of titanium and its alloys in aerospace, medicine, energy and automotive technology.

  14. Chinese titanium industry

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    <正>The effects of the financial crisis on the titanium industry are visible: investment plans for titanium smelting and processing have basically come to a halt in 2009, and projects under construction were also delayed. However, the

  15. Delayed cementless total hip arthroplasty for neglected dislocation of hip combined with complex acetabular fracture and deficient bone stock

    Directory of Open Access Journals (Sweden)

    Gavaskar Ashok S

    2012-12-01

    Full Text Available 【Abstract】Total hip arthroplasty (THA for an un-treated acetabular fracture is technically challenging and the long-term result is not so favorable. A 45-year-old fe-male patient with untreated column and comminuted poste-rior wall fracture of the acetabulum was treated in our insti-tution by reconstruction of the posterior wall using iliac strut autograft and plate stabilization of the posterior col-umn with cancellous grafting and cementless THA in a single stage. At 3 years’ follow-up, the patient was independently mobile without limb length discrepancy. Radiological evalu-ation showed well integrated components and bone grafts. No evidence of aseptic loosening or osteolysis was found. This report aims to emphasize that bony acetabular recon-struction allows the use of primary hip components, which improves prosthesis longevity and preserves bone stock for a future revision. Key words: Acetabulum; Fractures, bone; Hip dislocation; Arthroplasty, replacement, hip

  16. Delayed cementless total hip arthroplasty for neglected dislocation of hip combined with complex acetabular fracture and deficient bone stock

    Institute of Scientific and Technical Information of China (English)

    Ashok S Gavaskar; Naveen Chowdary Tummala

    2012-01-01

    Total hip arthroplasty (THA) for an untreated acetabular fracture is technically challenging and the long-term result is not so favorable.A 45-year-old female patient with untreated column and comminuted posterior wall fracture of the acetabulum was treated in our institution by reconstruction of the posterior wall using iliac strut autograft and plate stabilization of the posterior column with cancellous grafting and cementless THA in a single stage.At 3 years' follow-up,the patient was independently mobile without limb length discrepancy.Radiological evaluation showed well integrated components and bone grafts.No evidence of aseptic loosening or osteolysis was found.This report aims to emphasize that bony acetabular reconstruction allows the use of primary hip components,which improves prosthesis longevity and preserves bone stock for a future revision.

  17. Titanium Carbide-Graphite Composites

    Science.gov (United States)

    1991-11-08

    titanium carbide , titanium carbide with free graphite, titanium carbide /vanadium carbide alloy with free graphite, and titanium carbide with...from melts. The test pins were drawn across hot pressed titanium carbide wear plates with 5 newtons of normal force. The lowest friction coefficient at...22 C was 0.12 obtained with pure titanium carbide . The lowest friction coefficient at 900 C was 0.19 obtained with titanium carbide with boron and

  18. A prospective comparative study of cementless total hip arthroplasty and hip resurfacing in patients under the age of 55 years: a ten-year follow-up.

    Science.gov (United States)

    Haddad, F S; Konan, S; Tahmassebi, J

    2015-05-01

    The aim of this study was to evaluate the ten-year clinical and functional outcome of hip resurfacing and to compare it with that of cementless hip arthroplasty in patients under the age of 55 years. Between 1999 and 2002, 80 patients were enrolled into the study: 24 were randomised (11 to hip resurfacing, 13 to total hip arthroplasty), 18 refused hip resurfacing and chose cementless total hip arthroplasty with a 32 mm bearing, and 38 insisted on resurfacing. The mean follow-up for all patients was 12.1 years (10 to 14). Patients were assessed clinically and radiologically at one year, five years and ten years. Outcome measures included EuroQol EQ5D, Oxford, Harris hip, University of California Los Angeles and University College Hospital functional scores. No differences were seen between the two groups in the Oxford or Harris hip scores or in the quality of life scores. Despite a similar aspiration to activity pre-operatively, a higher proportion of patients with a hip resurfacing were running and involved in sport and heavy manual labour after ten years. We found significantly higher function scores in patients who had undergone hip resurfacing than in those with a cementless hip arthroplasty at ten years. This suggests a functional advantage for hip resurfacing. There were no other attendant problems.

  19. Surface protection treatments of highly porous building stones and sustainability problems

    Science.gov (United States)

    Calia, Angela; Lettieri, Maria Teresa; Matera, Loredana; Sileo, Maria

    2013-04-01

    The growing attention to the cultural value and the potential touristic attraction of the historic towns has led to increasing activities of rehabilitation and conservation of the historical built heritage. Chemical treatments have become a common practice for the protection of the stone building surface against the decay agents and traditional methods of protection, such as the application of sacrificial layers, have been even more neglected. The use of chemical products on large scale works on the historical built heritage draws the attention towards the sustainability of the conservation treatments, that involve peculiar features with relation to the different types of stones. Sustainability is undoubtedly in terms of human and environmental impact of the used products, so that the use of new formulations based on aqueous solvent should be preferred. Sustainability also means the equilibrium between the required performances of the treatments and the preservation of the original stone properties (colour, permeability, etc), namely harmlessness and effectiveness of the treatments. This can be a critical aspect when we deal with very porous stones, namely having porosity between 30-40%, that are widely used in many countries as traditional building materials. In most cases no information - or very general recommendations - is reported in the technical sheets of the conservation products with reference to the application to these types of stones. Relevant problems of compatibility can arise from the significant amounts absorbed by the high porous structure, as well as in terms of cost effectiveness of the treatments. In this work several calcarenites with different petro-physic characteristics and porosity between 30 and 45% are concerned for the assessment of the performance of two commercial water based products for stone protection, respectively an alcoxy-siloxane with low molecular weight and a modified organo-silane. This activity is a part of the Apulia

  20. Titanium based flat heat pipes for computer chip cooling

    Science.gov (United States)

    Soni, Gaurav; Ding, Changsong; Sigurdson, Marin; Bozorgi, Payam; Piorek, Brian; MacDonald, Noel; Meinhart, Carl

    2008-11-01

    We are developing a highly conductive flat heat pipe (called Thermal Ground Plane or TGP) for cooling computer chips. Conventional heat pipes have circular cross sections and thus can't make good contact with chip surface. The flatness of our TGP will enable conformal contact with the chip surface and thus enhance cooling efficiency. Another limiting factor in conventional heat pipes is the capillary flow of the working fluid through a wick structure. In order to overcome this limitation we have created a highly porous wick structure on a flat titanium substrate by using micro fabrication technology. We first etch titanium to create very tall micro pillars with a diameter of 5 μm, a height of 40 μm and a pitch of 10 μm. We then grow a very fine nano structured titania (NST) hairs on all surfaces of the pillars by oxidation in H202. In this way we achieve a wick structure which utilizes multiple length scales to yield high performance wicking of water. It's capable of wicking water at an average velocity of 1 cm/s over a distance of several cm. A titanium cavity is laser-welded onto the wicking substrate and a small quantity of water is hermetically sealed inside the cavity to achieve a TGP. The thermal conductivity of our preliminary TGP was measured to be 350 W/m-K, but has the potential to be several orders of magnitude higher.

  1. Porous Titanium for Dental Implant Applications

    Directory of Open Access Journals (Sweden)

    Zena J. Wally

    2015-10-01

    Full Text Available Recently, an increasing amount of research has focused on the biological and mechanical behavior of highly porous structures of metallic biomaterials, as implant materials for dental implants. Particularly, pure titanium and its alloys are typically used due to their outstanding mechanical and biological properties. However, these materials have high stiffness (Young’s modulus in comparison to that of the host bone, which necessitates careful implant design to ensure appropriate distribution of stresses to the adjoining bone, to avoid stress-shielding or overloading, both of which lead to bone resorption. Additionally, many coating and roughening techniques are used to improve cell and bone-bonding to the implant surface. To date, several studies have revealed that porous geometry may be a promising alternative to bulk structures for dental implant applications. This review aims to summarize the evidence in the literature for the importance of porosity in the integration of dental implants with bone tissue and the different fabrication methods currently being investigated. In particular, additive manufacturing shows promise as a technique to control pore size and shape for optimum biological properties.

  2. Three-Dimensional Analysis of the Contact Pattern between the Cortical Bone and Femoral Prosthesis after Cementless Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Hiroshi Wada

    2016-01-01

    Full Text Available The cementless stem Excia (B. Braun, Melsungen, Germany implant has a rectangular cross-sectional shape with back-and-forth flanges and a plasma-sprayed, dicalcium phosphate dihydrate coating from the middle to proximal portion to increase initial fixation and early bone formation. Here, the conformity of the Excia stem to the femoral canal morphology was three-dimensionally assessed using computed tomography. Forty-three patients (45 hips were examined after primary total hip arthroplasty with a mean follow-up of 27 ± 3 months (range: 24–36 months. Spot welds occurred at zone 2 in 16 hips and at zone 6 in 24 hips, with 83% (20/24 hips of those occurring within 3 months after surgery. First- (n=12 hips, second- (n=32, and third- (n=1 degree stress shielding were observed. The stem was typically in contact with the cortical bone in the anterolateral mid-portion (100% and posteromedial distal portions (85%. Stress shielding did not progress, even in cases where the stems were in contact with the distal portions. The anterior flange was in contact with the bone in all cases. The stability of the mid-lateral portion with the dicalcium phosphate dihydrate coating and the anterior flange may have inhibited the progression of stress shielding beyond the second degree.

  3. Experimental and Numerical Analyses of the Pull-out Response of a Steel Post/Bovine Bone Cementless Fixation

    Institute of Scientific and Technical Information of China (English)

    Khaled Gammoudi; Mohamed Kharrat; Maher Dammak

    2012-01-01

    Effect of initial interference fit on pull-out strength in cementless fixation between bovine tibia and smooth stainless steel post was investigated in this study.Compressive behavior of bovine spongious bone was studied using mechanical testing in order to evaluate the elastic-plastic properties in different regions of the proximal tibia.Friction tests were carried out in the aim to evaluate the friction behavior of the contact between bovine spongious bone and stainless steel.A cylindrical stainless steel post inserted in a pre-drilled bovine tibia with an initial interference fit was taken as an in vitro model to assess the contribution of post fixation to the initial stability of the Total Knee Arthroplasty (TKA) tibial component.Pull-out experiments were carried out for different initial interference fits.Finite Element Models (FEM) using local elastic-plastic properties of the bovine bone were developed for the analysis of the experimental ultimate pull-out force results.At the post/bone interface,Coulomb friction was considered in the FEM calculations with pressure-dependent friction coefficient.It was found that the FEM results of the ultimate force are in good agreement with the experimental results.The analysis of the FEM interfacial stresses indicates that the micro-slip initiation depends on the local bone properties.

  4. The effects of pulsed low frequency magnetic field in early rehabilitation of patients with cementless total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Đurović Aleksandar

    2006-01-01

    Full Text Available Introduction: Early rehabilitation of patients with cementless total hip arthroplasty (cTHA includes different physical modalities and pulsed low frequency magnetic field (PLFMF, which effects have not been explored yet. Objective: To investigate the effects of PLFMF which was applied in different doses in early rehabilitation of patients with cTHA. Method: Prospective, controlled, clinical study included 90 patients, divided in three groups with 30 patients each. First two groups were treated with high (group A or low (group B doses of PLFMF, in addition to kinesitherapy. Control group C was treated only with kinesitherapy. Study was completed in three weeks. Results: Subjects of group A had significantly lower pain than group B (p<0.01 and group C (p<0.001 subjects in the first postoperative week. Pain in group B subjects was significantly lower than in group C in all three postoperative weeks (p<0.01. In relation to other two groups, subjects of group A had higher hip Harris score values at the end of the third postoperative week (p<0.05, and they were faster on 10-meter distance at the end of the first postoperative week (p<0.01. Conclusion: PLFMF used in low and high doses for patients with cTHA had significant effects on pain abatement, especially at higher doses. Improvement of function was earlier and more manifested in the group treated with high doses of PLFMF.

  5. Cementless total hip arthroplasty with modified oblique femoral shortening osteotomy in Crowe type IV congenital hip dislocation.

    Science.gov (United States)

    Kiliçoğlu, Onder İ; Türker, Mehmet; Akgül, Turgut; Yazicioğlu, Onder

    2013-01-01

    Midterm results of cementless total hip arthroplasty in patients with Crowe type IV congenital dislocation of the hip were evaluated. A modified oblique subtrochanteric shortening osteotomy was used in all patients. A cylindrical femoral stem was used in all patients to stabilize the osteotomy. Mean follow-up was 82 months in 20 hips of 16 patients. Mean Merle D'Aubigné pain score increased from 2.52 to 5.65 points, function score improved from 4.0 to 5.3 points, and mobility score improved from 3.95 to 5.35. Mean greater trochanter height relative to the estimated hip center was 6.8 ± 2.0 cm preoperatively and -1 ± 0.2 cm postoperatively. Complications were dislocations in 3 patients, which were successfully managed without redislocation and fracture of greater trochanter in 3 patients, which healed uneventfully in 2 but with residual Trendelenburg gait in one. Total hip arthroplasty with modified oblique subtrochanteric shortening osteotomy is an effective technique for the treatment for Crowe type IV hip dislocation.

  6. Optimization of custom cementless stem using finite element analysis and elastic modulus distribution for reducing stress-shielding effect.

    Science.gov (United States)

    Saravana Kumar, Gurunathan; George, Subin Philip

    2017-02-01

    This work proposes a methodology involving stiffness optimization for subject-specific cementless hip implant design based on finite element analysis for reducing stress-shielding effect. To assess the change in the stress-strain state of the femur and the resulting stress-shielding effect due to insertion of the implant, a finite element analysis of the resected femur with implant assembly is carried out for a clinically relevant loading condition. Selecting the von Mises stress as the criterion for discriminating regions for elastic modulus difference, a stiffness minimization method was employed by varying the elastic modulus distribution in custom implant stem. The stiffness minimization problem is formulated as material distribution problem without explicitly penalizing partial volume elements. This formulation enables designs that could be fabricated using additive manufacturing to make porous implant with varying levels of porosity. Stress-shielding effect, measured as difference between the von Mises stress in the intact and implanted femur, decreased as the elastic modulus distribution is optimized.

  7. Correlative analysis of MRI-evident abductor hip muscle degeneration and power after minimally invasive versus conventional unilateral cementless THA.

    Science.gov (United States)

    Vasilakis, Ioannis; Solomou, Ekaterini; Vitsas, Vasilis; Fennema, Peter; Korovessis, Panagiotis; Siamblis, Dimitrios K

    2012-12-01

    The 2 main null hypotheses of this study were: (1) the 4-year surgical trauma-related degeneration within the hip abductor muscles after a minimally invasive approach to total hip arthroplasty would be similar to that following a conventional approach; and (2) no differences in perioperative blood loss or postoperative hip pain would be observed between the minimally invasive and conventional approaches.In 40 consecutive randomly selected adult patients with unilateral primary hip osteoarthritis, a cementless Zweymüller-Plus THA (Smith & Nephew Orthopaedics, Baar, Switzerland) was implanted by a single surgeon in 1 institution during the same period. Twenty patients underwent a minimally invasive approach (group A), and 20 patients underwent a conventional anterolateral approach (group B). Four years postoperatively, the operated and contralateral nonoperated hips of 37 available patients from both groups were examined with magnetic resonance imaging to show any changes in the gluteus medius and tensor fascia latae. Simultaneously, hip abductor power was measured bilaterally in both groups. Anthropometric data, blood loss, Short Form 36 self-assessment questionnaire, visual analog pain score, and walking distance were also analyzed.The reliability of magnetic resonance imaging and hip abductor power measurements was high. No difference was found in hip abductor power on the operated side between the 2 groups, whereas hip abductor power on the nonoperated side was significantly higher in both groups. This study revealed no mechanical and functional benefits in favor of patients undergoing minimally invasive vs conventional total hip arthroplasty.

  8. A comparative study of zinc, magnesium, strontium-incorporated hydroxyapatite-coated titanium implants for osseointegration of osteopenic rats

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Zhou-Shan [Department of Orthopaedic Surgery, Second Affiliated Hospital of Wenzhou Medical University, 109 Xueyuan Xi Road, Wenzhou, Zhejiang 325027 (China); Zhou, Wan-Shu [Endocrine & Metabolic Diseases Unit, Affiliated Hospital of Guizhou Medical University, Guizhou 550001 (China); He, Xing-Wen [Department of Orthopaedic Surgery, Hangzhou Bay Hospital of Ningbo, 315000 (China); Liu, Wei [Department of Orthopaedic Surgery, Jingmen No. 1 People' s Hospital, Jingmen 44800, Hubei (China); Bai, Bing-Li; Zhou, Qiang; Huang, Zheng-Liang; Tu, Kai-kai; Li, Hang; Sun, Tao [Department of Orthopaedic Surgery, Second Affiliated Hospital of Wenzhou Medical University, 109 Xueyuan Xi Road, Wenzhou, Zhejiang 325027 (China); Lv, Yang-Xun [Department of Orthopaedic Surgery, Wenzhou Central Hospital, Wenzhou, Zhejiang 325000 (China); Cui, Wei [Sichuan Provincial Orthopedics Hospital, No. 132 West First Section First Ring Road, Chengdu, Sichuan 610000 (China); Yang, Lei, E-mail: tzs19900327@163.com [Department of Orthopaedic Surgery, Second Affiliated Hospital of Wenzhou Medical University, 109 Xueyuan Xi Road, Wenzhou, Zhejiang 325027 (China)

    2016-05-01

    Surface modification techniques have been applied to generate titanium implant surfaces that promote osseointegration for the implants in cementless arthroplasty. However, its effect is not sufficient for osteoporotic bone. Zinc (Zn), magnesium (Mg), and strontium (Sr) present a beneficial effect on bone growth, and positively affect bone regeneration. The aim of this study was to confirm the different effects of the fixation strength of Zn, Mg, Sr-substituted hydroxyapatite-coated (Zn-HA-coated, Mg-HA-coated, Sr-HA-coated) titanium implants via electrochemical deposition in the osteoporotic condition. Female Sprague–Dawley rats were used for this study. Twelve weeks after bilateral ovariectomy, all animals were randomly divided into four groups: group HA; group Zn-HA; group Mg-HA and group Sr-HA. Afterwards, all rats from groups HA, Zn-HA, Mg-HA and Sr-HA received implants with hydroxyapatite containing 0%, 10% Zn ions, 10% Mg ions, and 10% Sr ions. Implants were inserted bilaterally in all animals until death at 12 weeks. The bilateral femurs of rats were harvested for evaluation. All treatment groups increased new bone formation around the surface of titanium rods and push-out force; group Sr-HA showed the strongest effects on new bone formation and biomechanical strength. Additionally, there are significant differences in bone formation and push-out force was observed between groups Zn-HA and Mg-HA. This finding suggests that Zn, Mg, Sr-substituted hydroxyapatite coatings can improve implant osseointegration, and the 10% Sr coating exhibited the best properties for implant osseointegration among the tested coatings in osteoporosis rats. - Highlights: • Surface modification techniques have been applied to generate titanium implant surfaces that promote osseointegration for the implants in cementless arthroplasty. • However, its effect is not sufficient for osteoporotic bone. Zinc (Zn), Magnesium(Mg), Strontium (Sr) present a benificial effect on bone

  9. Fabrication of highly porous keratin sponges by freeze-drying in the presence of calcium alginate beads

    Energy Technology Data Exchange (ETDEWEB)

    Hamasaki, Shinichi; Tachibana, Akira; Tada, Daisuke; Yamauchi, Kiyoshi [Department of Applied Chemistry and Bioengineering, Graduate School of Engineering, Osaka City University, 3-3-138 Sugimoto, Sumiyoshi-ku, Osaka 558-8585 (Japan); Tanabe, Toshizumi [Department of Applied Chemistry and Bioengineering, Graduate School of Engineering, Osaka City University, 3-3-138 Sugimoto, Sumiyoshi-ku, Osaka 558-8585 (Japan)], E-mail: tanabe@bioa.eng.osaka-cu.ac.jp

    2008-12-01

    Novel fabrication method of highly porous and flexible keratin sponges was developed by combining a particulate-leaching method and a freeze-drying method. Reduced keratin aqueous solution was mixed with dried calcium alginate beads and was lyophilized to give keratin/calcium alginate complex, which was subsequently treated with EDTA solution to leach out calcium alginate beads. The resultant keratin sponge was flexible enough to handle even in dried state because of its quite high porosity (98.9 {+-} 0.1%), which was brought about by the large and small pores formed by the elimination of calcium alginate beads and water. The sponge supported the attachment and the proliferation of mouse fibroblast cells. Thus, the keratin sponge given by the present fabrication method afforded one alternative as a cell scaffold for tissue engineering.

  10. Evaluation of chondrocyte growth in the highly porous scaffolds made by fused deposition manufacturing (FDM) filled with type II collagen.

    Science.gov (United States)

    Yen, Hung-Jen; Tseng, Ching-Shiow; Hsu, Shan-Hui; Tsai, Ching-Lin

    2009-06-01

    Highly porous poly(D,L-lactide-co-glycolide) (PLGA) scaffolds for cartilage tissue engineering were fabricated in this study using the fused deposition manufacturing (FDM) process and were further modified by type II collagen. The average molecular weight of PLGA decreased to about 60% of the original value after the melt-extrusion process. Type II collagen exhibited sponge-like structure and filled the macroporous FDM scaffolds. An increase of the fiber spacing resulted in an increase of the porosity. The storage modulus of FDM scaffolds with a large fiber spacing was comparable to that of the native porcine articular cartilage. Although the FDM hybrid scaffolds were swollen in various extents after 28 days of in vitro culture, the seeded chondrocytes were well distributed in the interior of the scaffolds with a large fiber spacing and neocartilage was formed around the scaffolds. The study also suggested that a low processing temperature may be required to produce PLGA precision scaffolds using FDM.

  11. Two-stage revision surgery with preformed spacers and cementless implants for septic hip arthritis: a prospective, non-randomized cohort study

    Directory of Open Access Journals (Sweden)

    Logoluso Nicola

    2011-05-01

    Full Text Available Abstract Background Outcome data on two-stage revision surgery for deep infection after septic hip arthritis are limited and inconsistent. This study presents the medium-term results of a new, standardized two-stage arthroplasty with preformed hip spacers and cementless implants in a consecutive series of adult patients with septic arthritis of the hip treated according to a same protocol. Methods Nineteen patients (20 hips were enrolled in this prospective, non-randomized cohort study between 2000 and 2008. The first stage comprised femoral head resection, debridement, and insertion of a preformed, commercially available, antibiotic-loaded cement hip spacer. After eradication of infection, a cementless total hip arthroplasty was implanted in the second stage. Patients were assessed for infection recurrence, pain (visual analog scale [VAS] and hip joint function (Harris Hip score. Results The mean time between first diagnosis of infection and revision surgery was 5.8 ± 9.0 months; the average duration of follow up was 56.6 (range, 24 - 104 months; all 20 hips were successfully converted to prosthesis an average 22 ± 5.1 weeks after spacer implantation. Reinfection after total hip joint replacement occurred in 1 patient. The mean VAS pain score improved from 48 (range, 35 - 84 pre-operatively to 18 (range, 0 - 38 prior to spacer removal and to 8 (range, 0 - 15 at the last follow-up assessment after prosthesis implantation. The average Harris Hip score improved from 27.5 before surgery to 61.8 between the two stages to 92.3 at the final follow-up assessment. Conclusions Satisfactory outcomes can be obtained with two-stage revision hip arthroplasty using preformed spacers and cementless implants for prosthetic hip joint infections of various etiologies.

  12. Effects of bio-functionalizing surface treatments on the mechanical behavior of open porous titanium biomaterials.

    Science.gov (United States)

    Amin Yavari, S; Ahmadi, S M; van der Stok, J; Wauthle, R; Riemslag, A C; Janssen, M; Schrooten, J; Weinans, H; Zadpoor, A A

    2014-08-01

    Bio-functionalizing surface treatments are often applied for improving the bioactivity of biomaterials that are based on otherwise bioinert titanium alloys. When applied on highly porous titanium alloy structures intended for orthopedic bone regeneration purposes, such surface treatments could significantly change the static and fatigue properties of these structures and, thus, affect the application of the biomaterial as bone substitute. Therefore, the interplay between biofunctionalizing surface treatments and mechanical behavior needs to be controlled. In this paper, we studied the effects of two bio-functionalizing surface treatments, namely alkali-acid heat treatment (AlAcH) and acid-alkali (AcAl), on the static and fatigue properties of three different highly porous titanium alloy implants manufactured using selective laser melting. It was found that AlAcH treatment results in minimal mass loss. The static and fatigue properties of AlAcH specimens were therefore not much different from as-manufactured (AsM) specimens. In contrast, AcAl resulted in substantial mass loss and also in significantly less static and fatigue properties particularly for porous structures with the highest porosity. The ratio of the static mechanical properties of AcAl specimens to that of AsM specimen was in the range of 1.5-6. The fatigue lives of AcAl specimens were much more severely affected by the applied surface treatments with fatigue lives up to 23 times smaller than that of AsM specimens particularly for the porous structures with the highest porosity. In conclusion, the fatigue properties of surface treated porous titanium are dependent not only on the type of applied surface treatment but also on the porosity of the biomaterial.

  13. Machining of titanium alloys

    CERN Document Server

    2014-01-01

    This book presents a collection of examples illustrating the resent research advances in the machining of titanium alloys. These materials have excellent strength and fracture toughness as well as low density and good corrosion resistance; however, machinability is still poor due to their low thermal conductivity and high chemical reactivity with cutting tool materials. This book presents solutions to enhance machinability in titanium-based alloys and serves as a useful reference to professionals and researchers in aerospace, automotive and biomedical fields.

  14. Titanium allergy: A literature review

    Directory of Open Access Journals (Sweden)

    Manish Goutam

    2014-01-01

    Full Text Available Titanium has gained immense popularity and has successfully established itself as the material of choice for dental implants. In both medical and dental fields, titanium and its alloys have demonstrated success as biomedical devices. Owing to its high resistance to corrosion in a physiological environment and the excellent biocompatibility that gives it a passive, stable oxide film, titanium is considered the material of choice for intraosseous use. There are certain studies which show titanium as an allergen but the resources to diagnose titanium sensivity are very limited. Attention is needed towards the development of new and precise method for early diagnosis of titanium allergy and also to find out the alternative biomaterial which can be used in place of titanium. A review of available articles from the Medline and PubMed database was done to find literature available regarding titanium allergy, its diagnosis and new alternative material for titanium.

  15. Facile synthesis of a mechanically robust and highly porous NiO film with excellent electrocatalytic activity towards methanol oxidation

    Science.gov (United States)

    Wang, Luoyuan; Zhang, Guoge; Liu, Yan; Li, Wenfang; Lu, Wei; Huang, Haitao

    2016-05-01

    Considerable research is being conducted in searching for effective anode catalysts in alkaline direct methanol fuel cells (DMFCs). Although significant progress has been achieved, it is still challenging to prepare non-Pt catalysts with both excellent activity and good durability. Herein, a highly porous NiO film is developed by a facile and fast anodization approach. The anodic NiO film demonstrates a high surface area, large mesopore volume and small crystallite size, leading to facilitated adsorption of reaction species, easy electrolyte penetration and fast reaction kinetics. Furthermore, as anodic NiO is grown in situ on a metallic substrate with strong adhesion strength and good electrical contact, it can be used directly as an anode catalyst for methanol oxidation without the need to add any binder or conducting agent. Such an additive-free approach greatly expedites the catalyst preparation process. The anodic NiO shows lower methanol oxidation potential, higher oxidation current and better catalytic durability than most of the state-of-the-art Ni-based catalysts reported elsewhere. As anodization is a simple, low cost and easily scaled up method, the work described here provides an exciting direction to speed up the practical application of alkaline DMFCs.Considerable research is being conducted in searching for effective anode catalysts in alkaline direct methanol fuel cells (DMFCs). Although significant progress has been achieved, it is still challenging to prepare non-Pt catalysts with both excellent activity and good durability. Herein, a highly porous NiO film is developed by a facile and fast anodization approach. The anodic NiO film demonstrates a high surface area, large mesopore volume and small crystallite size, leading to facilitated adsorption of reaction species, easy electrolyte penetration and fast reaction kinetics. Furthermore, as anodic NiO is grown in situ on a metallic substrate with strong adhesion strength and good electrical contact

  16. Highly porous ZnS microspheres for superior photoactivity after Au and Pt deposition and thermal treatment

    Energy Technology Data Exchange (ETDEWEB)

    Singla, Shilpa; Pal, Bonamali, E-mail: bpal@thapar.edu

    2013-11-15

    Graphical abstract: Highly porous ZnS microsphere of size 2–5 μm having large surface area ca. 173.14 m{sup 2} g{sup −1} exhibits superior photocatalytic activity for the oxidation of 4-nitrophenol under UV light irradiation. The rate of photooxidation has been significantly improved by Au and Pt deposition and after sintering, respectively, due to rapid electron acceptance by metal from photoexcited ZnS and growth of crystalline ZnS phase. - Highlights: • Photoactive ZnS microsphere of size 2–5 μm was prepared by hydrothermal route. • Highly porous cubic spherical ZnS crystals possess a large surface area, 173 m{sup 2} g{sup −1}. • 1 wt% Au and Pt photodeposition highly quenched the photoluminescence at 437 nm. • Sintering and metal loading notably improve the photooxidation rate of 4-nitrophenol. • Pt co-catalyst always exhibits superior photoactivity of ZnS microsphere than Au. - Abstract: This work highlights the enhanced photocatalytic activity of porous ZnS microspheres after Au and Pt deposition and heat treatment at 500 °C for 2 h. Microporous ZnS particles of size 2–5 μm with large surface area 173.14 m{sup 2} g{sup −1} and pore volume 0.0212 cm{sup 3} g{sup −1} were prepared by refluxing under an alkaline medium. Photoluminescence of ZnS at 437 nm attributed to sulfur or zinc vacancies were quenched to 30% and 49%, respectively, after 1 wt% Au and Pt loading. SEM images revealed that each ZnS microparticle consist of several smaller ZnS spheres of size 2.13 nm as calculated by Scherrer's equation. The rate of photooxidation of 4-nitrophenol (10 μM) under UV (125 W Hg arc–10.4 mW/cm{sup 2}) irradiation has been significantly improved by Au and Pt deposition followed by sintering due to better electron capturing capacity of deposited metals and growth of crystalline ZnS phase with less surface defects.

  17. Functional and radiographic evaluation and quality of life analysis after cementless total hip arthroplasty with ceramic bearings: minimum of 5 years follow-up

    Directory of Open Access Journals (Sweden)

    Rafael Borghi Mortat

    2013-12-01

    Full Text Available Objective: The aim of the study is to analyze and correlate functional and radiographic results and quality of life in patients undergoing cementless total hip arthroplasty with ceramic surface, performed at Hospital Servidor Publico de Sao Paulo from 2001 to 2006. Methods: We retrospectively analyzed 35 hips treated with cementless total hip arthroplasty with ceramic surfaces with a minimum follow-up of 5 years. Functional evaluation was based on the Harris Hip Score (HHS. Radiographic evaluation was based on the method proposed by Charles Engh for evaluation of femoral osseointegration and on DeLee and Charnley zones for acetabulum. Quality of life was assessed by SF-36 questionnaire. Results: The HHS presented excellent and good results in 91% of patients postoperatively (mean of 93.14 points HHS. As for radiographic evaluation, we found excellent results in 100% of evaluated hips (proven osseointegration. SF-36 scores were not compared to the control group for the following components: pain, vitality, mental health and social aspects. The difference between HHS pre and postoperatively had a statistically significant correlation with physical functioning of the SF-36. Conclusion: Total hip arthroplasty with ceramic surface is a treatment that enables functional improvement of the hip and increases quality of life of patients to levels close to those of people without joint diseases.

  18. Five-year results of a cementless short-hip-stem prosthesis

    Directory of Open Access Journals (Sweden)

    Ralf H. Wittenberg

    2013-03-01

    Full Text Available Hip prosthesis stems with a short stem length and proximal fixation geometry support a bone-preserving and muscle-sparing implantation and should also allow for revision surgery with a standard hip stem. We present 250 prospectively documented clinical and radiological results from the Metha Short Hip Stem prosthesis (B. Braun-Aesculap, Tuttlingen, Germany after an average follow-up of 4.9 years. The average patient age at surgery was 60 years. Indication for total hip replacement was primary osteoarthrosis (OA (78% of patients, OA based on developmental dyspla- sia of the hip (16%, and other indications (6%. At the last follow-up, the average Harris Hip Score was 97 points. 85% of patients were very satisfied and 14% were satisfied after surgery, whereas 1% were dissatisfied. Pain according to the Visual Analogue Scale improved from 7.4 (min 1.6, max 9.5 pre-operatively to 0.23 (min 0, max 6.6. No joint dislocations occurred when predominantly using 28 mm and 32 mm prosthesis heads. Nine short-stems were revised: three after bacterial infections, two after primary via valsa with penetration of the femoral cortex two and three months after surgery, and three after early aseptic cases of loosening within the first year. A further nine osseously consolidated short-stems had to be replaced due to breakage of the modular titanium cone adapter after an average of 3.1 years (min 1.9, max 4.4. All surgical revisions were performed using primary standard stems. Without taking the material-related adapter failures into account, a five year Kaplan-Meier survival rate of 96.7% (95% confidence interval 93.4-98.3 was determined for the short-stem prostheses. There were no radiological signs of loosening in any of the short-stem prostheses at the last examination. Fine sclerotic lines were detected in Gruen’s AP zones 1 (19% and 2 (10.5%, individual hypertrophies in zone 3 (3.5%, fine seams in zones 4 (5.5% and 5 (4%, without pedestal formations in zone 4

  19. Carbon/PEEK composite materials as an alternative for stainless steel/titanium hip prosthesis: a finite element study.

    Science.gov (United States)

    Rezaei, Farshid; Hassani, Kamran; Solhjoei, Nosratollah; Karimi, Alireza

    2015-12-01

    Total hip replacement (THR) has been ranked within the most typical surgical processes in the world. The durability of the prosthesis and loosening of prosthesis are the main concerns that mostly reported after THR surgeries. In THR, the femoral prosthesis can be fixed by either cement or cementless methods in the patient's bones. In both procedures, the stability of the prosthesis in the hosted bone has a key asset in its long-term durability and performance. This study aimed to execute a comparative finite element simulation to assess the load transfer between the prosthesis, which is made of carbon/PEEK composite and stainless steel/titanium, and the femur bone. The mechanical behavior of the cortical bone was assumed as a linear transverse isotropic while the spongy bone was modeled like a linear isotropic material. The implants were made of stainless steel (316L) and titanium alloy as they are common materials for implants. The results showed that the carbon/PEEK composites provide a flatter load transfer from the upper body to the leg compared to the stainless steel/titanium prosthesis. Furthermore, the results showed that the von Mises stress, principal stress, and the strain in the carbon/PEEK composites prosthesis were significantly lower than that made of the stainless steel/titanium. The results also imply that the carbon/PEEK composites can be applied to introduce a new optimum design for femoral prosthesis with adjustable stiffness, which can decrease the stress shielding and interface stress. These findings will help clinicians and biomedical experts to increase their knowledge about the hip replacement.

  20. Rapid synthesis of monodispersed highly porous spinel nickel cobaltite (NiCo2O4) electrode material for supercapacitors

    Science.gov (United States)

    Naveen, A. Nirmalesh; Selladurai, S.

    2015-06-01

    Monodispersed highly porous spinel nickel cobaltite electrode material was successfully synthesized in a short time using combustion technique. Single phase cubic nature of the spinel nickel cobaltite with average crystallite size of 24 nm was determined from X-ray diffraction study. Functional groups present in the compound were determined from FTIR study and it further confirms the spinel formation. FESEM images reveal the porous nature of the prepared material and uniform size distribution of the particles. Electrochemical evaluation was performed using Cyclic Voltammetry (CV) technique, Chronopotentiometry (CP) and Electrochemical Impedance Spectroscopy (EIS). Results reveal the typical pseudocapacitive behaviour of the material. Maximum capacitance of 754 F/g was calculated at the scan rate of 5 mV/s, high capacitance was due to the unique porous morphology of the electrode. Nyquist plot depicts the low resistance and good electrical conductivity of nickel cobaltite. It has been found that nickel cobaltite prepared by this typical method will be a potential electrode material for supercapcitor application.

  1. Synthesis of Highly Porous Poly(tert-butyl acrylate)-b-polysulfone-b-poly(tert-butyl acrylate) Asymmetric Membranes

    KAUST Repository

    Xie, Yihui

    2016-03-24

    For the first time, self-assembly and non-solvent induced phase separation was applied to polysulfone-based linear block copolymers, reaching mechanical stability much higher than other block copolymers membranes used in this method, which were mainly based on polystyrene blocks. Poly(tert-butyl acrylate)-b-polysulfone-b-poly(tert-butyl acrylate) (PtBA30k-b-PSU14k-b-PtBA30k) with a low polydispersity of 1.4 was synthesized by combining step-growth condensation and RAFT polymerization. Various advanced electron microscopies revealed that PtBA30k-b-PSU14k-b-PtBA30k assembles into worm-like cylindrical micelles in DMAc and adopts a “flower-like” arrangement with the PSU central block forming the shell. Computational modeling described the mechanism of micelle formation and morphological transition. Asymmetric nanostructured membranes were obtained with a highly porous interconnected skin layer and a sublayer with finger-like macrovoids. Ultrafiltration tests confirmed a water permeance of 555 L m-2 h-1 bar-1 with molecular weight cut-off of 28 kg/mol. PtBA segments on the membrane surface were then hydrolyzed and complexed with metals, leading to cross-linking and enhancement of antibacterial capability.

  2. Preparation of highly porous binderless activated carbon electrodes from fibres of oil palm empty fruit bunches for application in supercapacitors.

    Science.gov (United States)

    Farma, R; Deraman, M; Awitdrus, A; Talib, I A; Taer, E; Basri, N H; Manjunatha, J G; Ishak, M M; Dollah, B N M; Hashmi, S A

    2013-03-01

    Fibres from oil palm empty fruit bunches, generated in large quantities by palm oil mills, were processed into self-adhesive carbon grains (SACG). Untreated and KOH-treated SACG were converted without binder into green monolith prior to N2-carbonisation and CO2-activation to produce highly porous binderless carbon monolith electrodes for supercapacitor applications. Characterisation of the pore structure of the electrodes revealed a significant advantage from combining the chemical and physical activation processes. The electrochemical measurements of the supercapacitor cells fabricated using these electrodes, using cyclic voltammetry, electrochemical impedance spectroscopy and galvanostatic charge-discharge techniques consistently found that approximately 3h of activation time, achieved via a multi-step heating profile, produced electrodes with a high surface area of 1704m(2)g(-1) and a total pore volume of 0.889cm(3)g(-1), corresponding to high values for the specific capacitance, specific energy and specific power of 150Fg(-1), 4.297Whkg(-1) and 173Wkg(-1), respectively.

  3. Performances and Coating Morphology of a Siloxane-Based Hydrophobic Product Applied in Different Concentrations on a Highly Porous Stone

    Directory of Open Access Journals (Sweden)

    Mariateresa Lettieri

    2016-11-01

    Full Text Available Many polymers, able to confer a hydrophobicity to treated surfaces, have been proposed for the restoration and conservation of civil and monumental buildings. Polysiloxanes, and their precursors, the silanes, have been frequently employed for stone protection. To avoid decay of the treated surfaces, the effectiveness and harmlessness of the treatment need to be carefully evaluated before application in the field. In this study, a commercial alkyl-siloxane was tested as a protective treatment on a highly porous stone, starting from water solutions with different contents of the product. The treatments have been devised to try to balance the requirements and the sustainability of the conservative actions. Sustainability, in terms of costs and environmental impact, is regarded as a key factor in the 21st century. Morphological observations of the stone surface, static contact angle and colour measurements, water vapour transmission test, and tests of water absorption were carried out to characterize the untreated and treated stones. A concentration below the minimum level suggested by the manufacturer was still able to act as a good barrier against water. More concentrated solutions produced polymer accumulation and coatings with extended cracks. The properties of the treated stone were affected by the presence of cracks in the coating.

  4. Fabrication of highly porous scaffold materials based on functionalized oligolactides and preliminary results on their use in bone tissue engineering

    Directory of Open Access Journals (Sweden)

    Vogt S.

    2002-12-01

    Full Text Available Tissue engineering offers a promising new approach to repair bone defects. Its practical realisation is connected with the development of suitable scaffold materials. In the present work, functionalized oligolactides have been prepared and used as macromers for the scaffold fabrication The developed fabrication process leads to highly porous scaffolds, available in various shapes and sizes, with an open inter-connective pore structure and porosities up to 90 %. Degradable or even osteoconductive components as well as biocompatible co-monomers can be used as additives to modulate the scaffold properties. Under in vitro conditions, the scaffolds exhibit a continuous degradation with varying degradation rates depending on their material composition. In vitro studies on the cultivation of osteoblasts on the scaffolds were performed and revealed their excellent biocompatibility. Cell growth on the scaffold surfaces and inside the scaffolds, formation of extracellular matrix and starting mineralization were detected by microscopical and histological analyses. Based on these results the developed materials are well-suited candidates for the design of tailor-made matrices in bone tissue engineering

  5. In vitro investigation of orthopedic titanium-coated and brushite-coated surfaces using human osteoblasts in the presence of gentamycin.

    Science.gov (United States)

    Ince, Akif; Schütze, Norbert; Hendrich, Christian; Thull, Roger; Eulert, Jochen; Löhr, Jochen F

    2008-08-01

    Anti-infective coatings have been developed to protect the surfaces of cementless implants from bacterial colonization that is known to be a prerequisite for device-related infection. The aim of this study is to investigate the effect of brushite-coated arthroplasty surfaces on human osteoblasts and to evaluate the impact of concomitant exposure to gentamycin. We cultured human osteoblasts (hFOB 1.19) on brushite-coated and uncoated titanium alloy in the presence of gentamycin and analyzed cell function and vitality. Our results show that brushite-coated titanium alloy surfaces supported the function of osteoblasts and the expression of extracellular matrix even in the presence of highly dosed gentamycin. Brushite-coated titanium alloy surfaces supported osteogenic function, indicating that this coating could enhance implant osteointegration in vivo. Concomitant exposure to gentamycin slightly decreased osteoblastic activity in vitro, suggesting that there might also be negative effects in vivo. However, in vivo studies are necessary to validate these in vitro findings.

  6. Mandibular reconstruction with a bioactive-coated cementless Ti6Al4V modular endoprosthesis in Macaca fascicularis

    NARCIS (Netherlands)

    Chanchareonsook, N.; Tideman, H.; Lee, S.; Hollister, S.J.; Flanagan, C.; Jansen, J.A.

    2014-01-01

    The titanium mandibular modular endoprosthesis fixed with polymethylmethacrylate cement in the medullary space of the mandible has been introduced in previous studies. However, the internal parts of these devices have been found to be prone to loosening and wound dehiscence. The current study introd

  7. Titanium metal: extraction to application

    Energy Technology Data Exchange (ETDEWEB)

    Gambogi, Joseph (USGS, Reston, VA); Gerdemann, Stephen J.

    2002-09-01

    In 1998, approximately 57,000 tons of titanium metal was consumed in the form of mill products (1). Only about 5% of the 4 million tons of titanium minerals consumed each year is used to produce titanium metal, with the remainder primarily used to produce titanium dioxide pigment. Titanium metal production is primarily based on the direct chlorination of rutile to produce titanium tetrachloride, which is then reduced to metal using the Kroll magnesium reduction process. The use of titanium is tied to its high strength-to-weight ratio and corrosion resistance. Aerospace is the largest application for titanium. In this paper, we discuss all aspects of the titanium industry from ore deposits through extraction to present and future applications. The methods of both primary (mining of ore, extraction, and purification) and secondary (forming and machining) operations will be analyzed. The chemical and physical properties of titanium metal will be briefly examined. Present and future applications for titanium will be discussed. Finally, the economics of titanium metal production also are analyzed as well as the advantages and disadvantages of various alternative extraction methods.

  8. Surface modification of titanium and titanium alloys by ion implantation.

    Science.gov (United States)

    Rautray, Tapash R; Narayanan, R; Kwon, Tae-Yub; Kim, Kyo-Han

    2010-05-01

    Titanium and titanium alloys are widely used in biomedical devices and components, especially as hard tissue replacements as well as in cardiac and cardiovascular applications, because of their desirable properties, such as relatively low modulus, good fatigue strength, formability, machinability, corrosion resistance, and biocompatibility. However, titanium and its alloys cannot meet all of the clinical requirements. Therefore, to improve the biological, chemical, and mechanical properties, surface modification is often performed. In view of this, the current review casts new light on surface modification of titanium and titanium alloys by ion beam implantation.

  9. The influence of contact ratio and its location on the primary stability of cementless total hip arthroplasty: A finite element analysis.

    Science.gov (United States)

    Reimeringer, M; Nuño, N

    2016-05-03

    Cementless hip stems are fixed to the surrounding bone by means of press-fit. To ensure a good press-fit, current surgical technique specifies an under-reaming of the bone cavity using successively larger broaches. Nevertheless, this surgical technique is inaccurate. Several studies show that the contact ratio (percentage of stem interface in contact with bone) achieved after surgery can vary between 20% and 95%. Therefore, this study aimed to investigate the influence of the contact ratio and its location on the primary stability of a cementless total hip arthroplasty using finite element analysis. A straight tapered femoral stem implanted in a composite bone was subjected to stair climbing. Micromotion of 7600 nodes at the stem-bone interface was computed for different configurations of contact ratios between 2% and 98%) along the hip stem. Considering the 15 configurations evaluated, the average micromotion ranges between 27μm and 54μm. The percentage of the porous interface of the stem having micromotion below 40μm that allows bone ingrowth range between 25-57%. The present numerical study shows that full contact (100%) between stem and bone is not necessary to obtain a good primary stability. The stem primary stability is influenced by both the contact ratio and its location. Several configurations with contact ratio lower than 100% and involving either the proximal or the cortical contact provide better primary stability than the full contact configuration. However, with contact ratio lower than 40%, the stem should be in contact with cortical bone to ensure a good primary stability.

  10. Chondrogenesis of human bone marrow mesenchymal stromal cells in highly porous alginate-foams supplemented with chondroitin sulfate

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Zhao [Department of Orthopaedic, Trauma and Reconstructive Surgery, Charité-Universitätsmedizin-Berlin Campus Benjamin Franklin, Berlin (Germany); Nooeaid, Patcharakamon [Institute of Biomaterials, Department of Materials Science and Engineering, University of Erlangen-Nuremberg (Germany); Kohl, Benjamin [Department of Orthopaedic, Trauma and Reconstructive Surgery, Charité-Universitätsmedizin-Berlin Campus Benjamin Franklin, Berlin (Germany); Roether, Judith A.; Schubert, Dirk W. [Institute of Polymer Materials, Department of Materials Science and Engineering, University of Erlangen-Nuremberg (Germany); Meier, Carola [Department of Orthopaedic, Trauma and Reconstructive Surgery, Charité-Universitätsmedizin-Berlin Campus Benjamin Franklin, Berlin (Germany); Boccaccini, Aldo R. [Institute of Biomaterials, Department of Materials Science and Engineering, University of Erlangen-Nuremberg (Germany); Godkin, Owen; Ertel, Wolfgang; Arens, Stephan [Department of Orthopaedic, Trauma and Reconstructive Surgery, Charité-Universitätsmedizin-Berlin Campus Benjamin Franklin, Berlin (Germany); Schulze-Tanzil, Gundula, E-mail: gundula.schulze@pmu.ac.at [Department of Orthopaedic, Trauma and Reconstructive Surgery, Charité-Universitätsmedizin-Berlin Campus Benjamin Franklin, Berlin (Germany); Institute of Anatomy, Paracelsus Medical University, Nuremberg (Germany)

    2015-05-01

    To overcome the limited intrinsic cartilage repair, autologous chondrocyte or bone-marrow-derived mesenchymal stromal cell (BM-MSC) was implanted into cartilage defects. For this purpose suitable biocompatible scaffolds are needed to provide cell retention, chondrogenesis and initial mechanical stability. The present study should indicate whether a recently developed highly porous alginate (Alg) foam scaffold supplemented with chondroitin sulfate (CS) allows the attachment, survival and chondrogenesis of BM-MSCs and articular chondrocytes. The foams were prepared using a freeze-drying method; some of them were supplemented with CS and subsequently characterized for porosity, biodegradation and mechanical profile. BM-MSCs were cultured for 1–2 weeks on the scaffold either under chondrogenic or maintenance conditions. Cell vitality assays, histology, glycosaminoglycan (sGAG) assay, and type II and I collagen immunolabelings were performed to monitor cell growth and extracellular matrix (ECM) synthesis in the scaffolds. Scaffolds had a high porosity ~ 93–95% with a mean pore sizes of 237 ± 48 μm (Alg) and 197 ± 61 μm (Alg/CS). Incorporation of CS increased mechanical strength of the foams providing gradually CS release over 7 days. Most of the cells survived in the scaffolds. BM-MSCs and articular chondrocytes formed rounded clusters within the scaffold pores. The BM-MSCs, irrespective of whether cultured under non/chondrogenic conditions and chondrocytes produced an ECM containing sGAGs, and types II and I collagen. Total collagen and sGAG contents were higher in differentiated BM-MSC cultures supplemented with CS than in CS-free foams after 14 days. The cell cluster formation induced by the scaffolds might stimulate chondrogenesis via initial intense cell–cell contacts. - Highlights: • Alginate foam scaffolds revealed a high porosity and mean pore size of 197–237 μm. • Chondroitin sulfate was released over 14 days by the scaffolds. • Chondrocytes

  11. Highly porous organic polymers bearing tertiary amine group and their exceptionally high CO{sub 2} uptake capacities

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Ruth; Bhaumik, Asim, E-mail: msab@iacs.res.in

    2015-02-15

    We report a very simple and unique strategy for synthesis of a tertiary amine functionalized high surface area porous organic polymer (POP) PDVTA-1 through the co-polymerization of monomers divinylbenzene (DVB) and triallylamine (TAA) under solvothermal reaction conditions. Two different PDVTA-1 samples have been synthesized by varying the molar ratio of the monomers. The porous polymeric materials have been thoroughly characterized by solid state {sup 13}C CP MAS-NMR, FT-IR and UV–vis spectroscopy, N{sub 2} sorption, HR TEM and FE SEM to understand its chemical environment, nanostructure, bonding, morphology and related surface properties. PDVTA-1 with higher amine content (DVB/TAA=4.0) showed exceptionally high CO{sub 2} uptake capacity of 85.8 wt% (19.5 mmol g{sup −1}) at 273 K and 43.69 wt% (9.93 mmol g{sup −1}) at 298 K under 3 bar pressure, whereas relatively low amine loaded material (DVB/TAA=7.0) shows uptake capacity of 59.2 wt% (13.45 mmol g{sup −1}) at 273 K and 34.36 wt% (7.81 mmol g{sup −1}) at 298 K. Highly porous nanostructure together with very high surface area and basicity at the surface due to the presence of abundant basic tertiary amine N-sites in the framework of PDVTA-1 could be responsible for very high CO{sub 2} adsorption. - Graphical abstract: Exceptionally high CO2 uptake (85.8 wt % at 273 K) has been observed over a high surface area porous organic polymer PDVTA-1 synthesized through copolymerization of divinylbenzene and triallyl amine. - Highlights: • Designing the synthesis of a new N-rich cross-linked porous organic polymer PDVTA-1. • PDVTA-1 showed mesoporosity with very high surface area of 903 m{sup 2} g{sup −1}. • High surface area and presence of basic sites facilitates the CO{sub 2} uptake. • PDVTA-1 showed exceptionally high CO{sub 2} adsorption capacity of 85.8 wt% at 273 K, 3 bar pressure.

  12. High-temperature Titanium Alloys

    Directory of Open Access Journals (Sweden)

    A.K. Gogia

    2005-04-01

    Full Text Available The development of high-temperature titanium alloys has contributed significantly to the spectacular progress in thrust-to-weight ratio of the aero gas turbines. This paper presents anoverview on the development of high-temperature titanium alloys used in aero engines and potential futuristic materials based on titanium aluminides and composites. The role of alloychemistry, processing, and microstructure, in determining the mechanical properties of titanium alloys is discussed. While phase equilibria and microstructural stability consideration haverestricted the use of conventional titanium alloys up to about 600 "C, alloys based on TiPl (or,, E,AINb (0, TiAl (y, and titaniumltitanium aluminides-based composites offer a possibility ofquantum jump in the temperature capability of titanium alloys.

  13. Titanium Carbide: Nanotechnology, Properties, Application

    OpenAIRE

    Galevsky, G. V.; Rudneva, V. V.; Garbuzova, A. K.; Valuev, Denis Viktorovich

    2015-01-01

    The paper develops scientific and technological bases for fabrication of titanium carbide which is a nanocomponent of composite materials. The authors determine optimum technology specifications and the main titanium carbide properties: fineness of titaniferous raw materials, carbide-forming agent quantity, set temperature of plasma flow, tempering temperature, titanium carbide yield, productivity, specific surface, size and shape of particles. The paper includes equations to describe how the...

  14. Titanium Carbide: Nanotechnology, Properties, Application

    Science.gov (United States)

    Galevsky, G. V.; Rudneva, V. V.; Garbuzova, A. K.; Valuev, D. V.

    2015-09-01

    The paper develops scientific and technological bases for fabrication of titanium carbide which is a nanocomponent of composite materials. The authors determine optimum technology specifications and the main titanium carbide properties: fineness of titaniferous raw materials, carbide-forming agent quantity, set temperature of plasma flow, tempering temperature, titanium carbide yield, productivity, specific surface, size and shape of particles. The paper includes equations to describe how the major specifications of the fabrication technique influence the content of titanium carbide and free carbon in the end product.

  15. Chemical changes of titanium and titanium dioxide under electron bombardment

    OpenAIRE

    Romins Brasca; Luciana Ines Vergara; Mario César Guillermo Passeggi; Julio Ferrón

    2007-01-01

    The electron induced effect on the first stages of the titanium (Ti0) oxidation and titanium dioxide (Ti4+) chemical reduction processes has been studied by means of Auger electron spectroscopy. Using factor analysis we found that both processes are characterized by the appearance of an intermediate Ti oxidation state, Ti2O3 (Ti3+).

  16. Chemical changes of titanium and titanium dioxide under electron bombardment

    Directory of Open Access Journals (Sweden)

    Romins Brasca

    2007-09-01

    Full Text Available The electron induced effect on the first stages of the titanium (Ti0 oxidation and titanium dioxide (Ti4+ chemical reduction processes has been studied by means of Auger electron spectroscopy. Using factor analysis we found that both processes are characterized by the appearance of an intermediate Ti oxidation state, Ti2O3 (Ti3+.

  17. Titanium dioxide nanotube films

    Energy Technology Data Exchange (ETDEWEB)

    Roman, Ioan, E-mail: roman@metav-cd.ro [S.C. METAV-Research and Development S.R.L., Bucharest, 31C. A. Rosetti, 020011 (Romania); Trusca, Roxana Doina; Soare, Maria-Laura [S.C. METAV-Research and Development S.R.L., Bucharest, 31C. A. Rosetti, 020011 (Romania); Fratila, Corneliu [Research and Development National Institute for Nonferrous and Rare Metals, Pantelimon, 102 Biruintei, 077145 (Romania); Krasicka-Cydzik, Elzbieta [University of Zielona Gora, Department of Biomedical Engineering Division, 9 Licealna, 65-417 (Poland); Stan, Miruna-Silvia; Dinischiotu, Anca [University of Bucharest, Department of Biochemistry and Molecular Biology, 36-46 Mihail Kogalniceanu, 050107 (Romania)

    2014-04-01

    Titania nanotubes (TNTs) were prepared by anodization on different substrates (titanium, Ti6Al4V and Ti6Al7Nb alloys) in ethylene glycol and glycerol. The influence of the applied potential and processing time on the nanotube diameter and length is analyzed. The as-formed nanotube layers are amorphous but they become crystalline when subjected to subsequent thermal treatment in air at 550 °C; TNT layers grown on titanium and Ti6Al4V alloy substrates consist of anatase and rutile, while those grown on Ti6Al7Nb alloy consist only of anatase. The nanotube layers grown on Ti6Al7Nb alloy are less homogeneous, with supplementary islands of smaller diameter nanotubes, spread across the surface. Better adhesion and proliferation of osteoblasts was found for the nanotubes grown on all three substrates by comparison to an unprocessed titanium plate. The sensitivity towards bovine alkaline phosphatase was investigated mainly by electrochemical impedance spectroscopy in relation to the crystallinity, the diameter and the nature of the anodization electrolyte of the TNT/Ti samples. The measuring capacity of the annealed nanotubes of 50 nm diameter grown in glycerol was demonstrated and the corresponding calibration curve was built for the concentration range of 0.005–0.1 mg/mL. - Highlights: • Titania nanotubes (TNTs) on Ti, Ti6Al4V and Ti6Al7Nb substrates were prepared. • Quantitative dependences of anodization conditions on TNT features were established. • Morphology and electrochemical tests revealed inhomogeneity of TNT/Ti6Al7Nb films. • Particular characteristics of TNT films induce electrochemical sensitivity to ALP. • Annealed TNT/Ti impedimetric sensitivity towards ALP was demonstrated and quantified.

  18. 662髋Ribbed假体中远期临床疗效观察%Medio/long-term clinical observation of 662 Ribbed anatomic cementless prosthesis

    Institute of Scientific and Technical Information of China (English)

    史庆轩; 李佩佳; 孙磊; 赵汉平; 胡宏伟; 罗永忠; 田敏; 刘明; 包健

    2012-01-01

    [Objective ] To evaluate the median and long - term clinical effect of the Ribbed anatomic cementless prosthesis. [Methods] A retrospective study was held. A total of 728 hip9 in 697 patients undergone THR with Ribbed anatomic cementless prosthesis were reviewed between July 1997 and September 2008, 662 hips in 606 patients were available for follow -up, the mean follow - up period were 7. 9 years (from 3 to 14 years) . [ Results] The mean Harris Hip Score increased from 35. 6 preoperatively to 91.4 postoperatively. Excellent and good function rate was 95. 7%. [Conclusion] Ribbed anatomic ce-menlless prosthesis is found to be well with good clinical effect in the median and long - term clinical observation.%[目的]评价Ribbed解剖型非骨水泥固定股骨假体的中远期临床应用效果.[方法]回顾性分析本科1997年7月~2008年9月应用解剖型非骨水泥固定股骨假体行全髋关节置换的病人697例共728髋.实际随访606例662髋,随访率90.9%.随访时间最短3年,最长14年,平均7.9年.所用假体均为Ribbed假体.[结果]Harris评分术前平均35.6分,术后平均91.4分,优良率95.7%,关节功能满意.随访X线片均未见明显透光线及假体移位,未发现股骨柄假体无菌性松动.[结论]Ribbed假体设计合理,特点显著,中远期效果满意,值得临床推广应用.

  19. Compaction of Titanium Powders

    Energy Technology Data Exchange (ETDEWEB)

    Gerdemann, Stephen,J; Jablonski, Paul, J

    2011-05-01

    Accurate modeling of powder densification has been an area of active research for more than 60 years. The earliest efforts were focused on linearization of the data because computers were not readily available to assist with curve-fitting methods. In this work, eight different titanium powders (three different sizes of sponge fines<150 {micro}m,<75 {micro}m, and<45 {micro}m; two different sizes of a hydride-dehydride [HDH]<75 {micro}m and<45 {micro}m; an atomized powder; a commercially pure [CP] Ti powder from International Titanium Powder [ITP]; and a Ti 6 4 alloy powder) were cold pressed in a single-acting die instrumented to collect stress and deformation data during compaction. From these data, the density of each compact was calculated and then plotted as a function of pressure. The results show that densification of all the powders, regardless of particle size, shape, or chemistry, can be modeled accurately as the sum of an initial density plus the sum of a rearrangement term and a work-hardening term. These last two terms are found to be a function of applied pressure and take the form of an exponential rise.

  20. Purification and utilization of titanium

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Wonbaek; Yu, Hyosin; Chung, Inwha; Rhee, Kang In; Choi, Good Sun; Lee, Chulkyung; Youn, In Ju; Chung, Jinki; Suh, Chang Youl; Yang, Dong Hyo [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1997-12-01

    Current domestic market appears not to be sufficient enough for the large scale investment for the expensive vacuum-melting equipment. Besides, related ingot-processing technologies like rolling, extrusion, and forging of titanium should be prepared in advance. In the mean time, the attempt to recycle expensive titanium scraps produced in our nation would be worthwhile in view of the reduction of import from foreign countries and of saving valuable secondary resources. The objectives for this research is to develop technology for the production of high purity titanium metals from sponges and scraps and to extend the developed technology to industrial applications. PREP(Plasma-Rotating-Electrode Process) and HDP(Hydride-Dehydride Process) were adopted to evaluate the possibility of using domestic titanium scraps in the production of pure titanium powders. Those scraps were titanium pipes of Grade 2 and various sputtering targets having a purity of 99.995%. The titanium powders produced by both methods were examined and compared with conventionally prepared ones. Their shape, size distribution, structure and above of all major impurities were determine to evaluate these process. The powders produced by PREP were of round shape having narrow size distribution at about 200 micron. Meanwhile, HDP powders were irregular shaped having a much wider size distribution. Both metallic and non-metallic impurities were lower in PREP powders due to the unavoidable contamination during crushing processes in HDP. Thus, PREP has advantages towards purity and uniformity while HDP toward finer sizes. Apparently, for the production of high purity titanium powders by HDP, special considerations should be made to prevent contamination during various steps in the process. In PREP powders, smaller particles contained more oxygen since they have larger surface/volume ratio. The tendency was also observed in the hardness measurement revealing the strengthening effect of oxygen in pure

  1. Bony healing of unstable thoracolumbar burst fractures in the elderly using percutaneously applied titanium mesh cages and a transpedicular fixation system with expandable screws.

    Directory of Open Access Journals (Sweden)

    Anica Eschler

    Full Text Available There is a high incidence of vertebral burst fractures following low velocity trauma in the elderly. Treatment of unstable vertebral burst fractures using the same principles like in stable vertebral burst fractures may show less favourable results in terms of fracture reduction, maintenance of reduction and cement leakage. In order to address these shortcomings this study introduces cementless fixation of unstable vertebral burst fractures using internal fixators and expandable intravertebral titanium mesh cages in a one-stage procedure via minimum-invasive techniques.A total of 16 consecutive patients (median age 76 years, range 58-94 with unstable thoracolumbar burst fractures and concomitant osteoporosis were treated by an internal fixator inserted via minimum invasive technique one level above and below the fractured vertebra. Fracture reduction was achieved and maintained by transpedicular placement of two titanium mesh cages into the fractured vertebral body during the same procedure. Intra- and postoperative safety of the procedure as well as analysis of reduction quality was analysed by 3D C-arm imaging or CT, respectively. Clinical and radiographic follow-up averaged 10.4 months (range 4.5-24.5.Stabilization of the collapsed vertebral body was achieved in all 16 cases without any intraoperative complication. Surgical time averaged 102 ± 6.6 minutes (71-194. The postoperative kyphotic angle (KA and Cobb angle revealed significant improvements (KA 13.7° to 7.4°, p < 0.001; Cobb 9.6° to 6.0°, p < 0.002 with partial loss of reduction at final follow-up (KA 8.3°, Cobb 8.7°. VAS (Visual Analogue Scale improved from 7.6 to 2.6 (p < 0.001. Adjacent fractures were not observed. One minor (malposition of pedicle screw complication was encountered.Cementless fixation of osteoporotic burst fractures revealed substantial pain relief, adequate maintenance of reduction and a low complication rate. Bony healing after unstable osteoporotic burst

  2. Antimicrobial titanium/silver PVD coatings on titanium

    OpenAIRE

    Thull Roger; Glückermann Susanne K; Ewald Andrea; Gbureck Uwe

    2006-01-01

    Abstract Background Biofilm formation and deep infection of endoprostheses is a recurrent complication in implant surgery. Post-operative infections may be overcome by adjusting antimicrobial properties of the implant surface prior to implantation. In this work we described the development of an antimicrobial titanium/silver hard coating via the physical vapor deposition (PVD) process. Methods Coatings with a thickness of approximately 2 μm were deposited on titanium surfaces by simultaneous ...

  3. Hydrolytically stable titanium-45

    DEFF Research Database (Denmark)

    Severin, Gregory; Fonslet, Jesper; Zhuravlev, Fedor

    2014-01-01

    Introduction Titanium-45, a candidate PET isotope, is under-employed largely because of the challenging aqueous chemistry of Ti(IV). The propensity for hydrolysis of Ti(IV) compounds makes radio-labeling difficult and excludes 45Ti from use in bio-conjugate chemistry. This is unfortunate because...... the physical characteristics are extremely desirable: 45Ti has a 3 hour half-life, a positron branching ratio of 85 %, a low Eβmax of 1.04 MeV, and negligible secondary gamma emission. In terms of isotope production, 45Ti is transmuted from naturally mono-isotopic 45Sc by low energy proton irradiation...... University of Jerusalem) and Thomas Huhn (University of Konstanz) have synthesized several stable Ti(IV) compounds based upon the salan ligand [1,2]. Additionally, these compounds have shown heightened cyto-toxicity against HT-29 (human colorectal cancer) cells, amongst others, as compared to traditional...

  4. Hemocompatibility of titanium nitride.

    Science.gov (United States)

    Dion, I; Baquey, C; Candelon, B; Monties, J R

    1992-10-01

    The left ventricular assist device is based on the principle of the Maillard-Wenkel rotative pump. The materials which make up the pump must present particular mechanical, tribological, thermal and chemical properties. Titanium nitride (TiN) because of its surface properties and graphite because of its bulk characteristics have been chosen. The present study evaluated the in vitro hemocompatibility of TiN coating deposited by the chemical vapor deposition process. Protein adsorption, platelet retention and hemolysis tests have been carried out. In spite of some disparities, the TiN behavior towards albumin and fibrinogen is interesting, compared with the one of a reference medical grade elastomer. The platelet retention test gives similar results as those achieved with the same elastomer. The hemolysis percentage is near to zero. TiN shows interesting characteristics, as far as mechanical and tribological problems are concerned, and presents very encouraging blood tolerability properties.

  5. Advanced titanium processing

    Energy Technology Data Exchange (ETDEWEB)

    Hartman, Alan D.; Gerdemann, Stephen J.; Schrems, Karol K.; Holcomb, Gordon R.; Argetsinger, Edward R.; Hansen, Jeffrey S.; Paige, Jack I.; Turner, Paul C.

    2001-01-01

    The Albany Research Center of the U.S. Department of Energy has been investigating a means to form useful wrought products by direct and continuous casting of titanium bars using cold-wall induction melting rather than current batch practices such as vacuum arc remelting. Continuous ingots produced by cold-wall induction melting, utilizing a bottomless water-cooled copper crucible, without slag (CaF2) additions had minor defects in the surface such as ''hot tears''. Slag additions as low as 0.5 weight percent were used to improve the surface finish. Therefore, a slag melted experimental Ti-6Al-4V alloy ingot was compared to a commercial Ti-6Al-4V alloy ingot in the areas of physical, chemical, mechanical, and corrosion attributes to address the question, ''Are any detrimental effects caused by slag addition''?

  6. Reactive removal of 2-chloroethyl ethyl sulfide vapors under visible light irradiation by cerium oxide modified highly porous zirconium (hydr) oxide

    Science.gov (United States)

    Mitchell, Joshua K.; Arcibar-Orozco, Javier A.; Bandosz, Teresa J.

    2016-12-01

    Highly porous cerium oxide modified Zr(OH)4 samples were synthesized using a simple one stage urea precipitation method. The amorphicity level of zirconium hydroxide did not change upon addition of cerium oxide particles. A unique aspect of the cerium oxide-modified materials is the presence of both the oxide (CeO2) and hydroxide (Zr(OH)4) phases resulting in a unique microporous structure of the final material. Extensive characterization using various chemical and physical methods revealed significant differences in the surface features. All synthesized materials were microporous and small additions of cerium oxide affected the surface chemistry. These samples were found as effective catalysts for a decontamination of mustard gas surrogate, 2-chloroethyl ethyl sulfide (CEES). Cerium oxide addition significantly decreased the band gap of zirconium hydroxide. Ethyl vinyl sulfide and 1,2-bis (Ethyl thio) ethane were identified as surface reaction products.

  7. Electrochemical process of titanium extraction

    Institute of Scientific and Technical Information of China (English)

    CH. RVS. NAGESH; C. S. RAMACHANDRAN

    2007-01-01

    A wide variety of processes are being pursued by researchers for cost effective extraction of titanium metal. Electrochemical processes are promising due to simplicity and being less capital intensive. Some of the promising electrochemical processes of titanium extraction were reviewed and the results of laboratory scale experiments on electrochemical reduction of TiO2 granules were brought out. Some of the kinetic parameters of the reduction process were discussed while presenting the quality improvements achieved in the experimentation.

  8. Low cost titanium--myth or reality

    Energy Technology Data Exchange (ETDEWEB)

    Turner, Paul C.; Hartman, Alan D.; Hansen, Jeffrey S.; Gerdemann, Stephen J.

    2001-01-01

    In 1998, approximately 57,000 tons of titanium metal was consumed in the form of mill products (1). Only about 5% of the 4 million tons of titanium minerals consumed each year is used to produce titanium metal, with the remainder primarily used to produce titanium dioxide pigment. Titanium metal production is primarily based on the direct chlorination of rutile to produce titanium tetrachloride, which is then reduced to metal using the Kroll magnesium reduction process. The use of titanium is tied to its high strength-to-weight ratio and corrosion resistance. Aerospace is the largest application for titanium, and titanium cost has prevented its use in non-aerospace applications including the automotive and heavy vehicle industries.

  9. Tuning anatase and rutile phase ratios and nanoscale surface features by anodization processing onto titanium substrate surfaces.

    Science.gov (United States)

    Roach, M D; Williamson, R S; Blakely, I P; Didier, L M

    2016-01-01

    Both the anatase (A) and rutile (R) phases of titanium oxide have shown enhanced antimicrobial and bioactivity levels but the specific A/R phase ratio needed for the best results is still unknown. In this study titanium samples were anodized to produce specific ratios of anatase and rutile phases within the oxide layers. Specific ratios produced included maximum A minimum R, minimum A maximum R, 50% A 50% R, minimum A minimum R, and a non-anodized titanium control group. Samples were characterized for phase distributions within the oxide layers, surface porosity, corrosion resistance, and bioactivity. Results indicated the targeted phase ratios were reproducibly achieved during the anodization process. Samples containing the highest levels of anatase showed the largest individual pore sizes, but a lower overall percent porosity value compared to samples containing higher rutile levels. EBSD examination of the anodized layer cross-sections provided valuable new spatial information on the distribution of anatase and rutile phases within the anodized layers. Highly porous oxide layers showed significantly higher corrosion rates compared to non-anodized titanium, but no significant differences were shown in the icorr values between samples containing primarily anatase phase, samples containing primarily rutile phase, and samples containing an approximate 50:50 mixture of the two phases. Minimum A minimum R samples showed substantially less porosity compared to the other anodization groups, a significantly lower oxide thickness, and comparable corrosion rates to non-anodized titanium. All samples within the study showed apatite production in simulated body fluid within the seven day test period indicating enhanced bioactivity.

  10. Cell response of anodized nanotubes on titanium and titanium alloys.

    Science.gov (United States)

    Minagar, Sepideh; Wang, James; Berndt, Christopher C; Ivanova, Elena P; Wen, Cuie

    2013-09-01

    Titanium and titanium alloy implants that have been demonstrated to be more biocompatible than other metallic implant materials, such as Co-Cr alloys and stainless steels, must also be accepted by bone cells, bonding with and growing on them to prevent loosening. Highly ordered nanoporous arrays of titanium dioxide that form on titanium surface by anodic oxidation are receiving increasing research interest due to their effectiveness in promoting osseointegration. The response of bone cells to implant materials depends on the topography, physicochemistry, mechanics, and electronics of the implant surface and this influences cell behavior, such as adhesion, proliferation, shape, migration, survival, and differentiation; for example the existing anions on the surface of a titanium implant make it negative and this affects the interaction with negative fibronectin (FN). Although optimal nanosize of reproducible titania nanotubes has not been reported due to different protocols used in studies, cell response was more sensitive to titania nanotubes with nanometer diameter and interspace. By annealing, amorphous TiO2 nanotubes change to a crystalline form and become more hydrophilic, resulting in an encouraging effect on cell behavior. The crystalline size and thickness of the bone-like apatite that forms on the titania nanotubes after implantation are also affected by the diameter and shape. This review describes how changes in nanotube morphologies, such as the tube diameter, the thickness of the nanotube layer, and the crystalline structure, influence the response of cells.

  11. Interfacial oxidations of pure titanium and titanium alloys with investments.

    Science.gov (United States)

    Ban, S; Watanabe, T; Mizutani, N; Fukui, H; Hasegawa, J; Nakamura, H

    2000-12-01

    External oxides of a commercially pure titanium (cpTi), Ti6Al4V alloy, and an experimental beta-type titanium alloy (Ti 53.4 wt%, Nb 29 wt%, Ta 13 wt%, and Zr 4.6 wt%) were characterized after heating to 600, 900, 1150, and 1400 degrees C in contact with three types of investments (alumina cement, magnesia cement, and phosphate-bonded) in air. XRD studies demonstrated that MgO, Li2TiO3 and/or Li2Ti3O7 were formed through reactions with the metal and the constituents in the magnesia cement-investment after heating to 900, 1150, and 1400 degrees C. Except for these conditions, TiO2 (rutile) was only formed on cpTi. For titanium alloys, the other components apart from Ti also formed simple and complex oxides such as Al2O3 and Al2TiO5 on Ti6Al4V, and Zr0.25Ti0.75Nb2O7 on the beta-type titanium alloy. However, no oxides containing V or Ta were formed. These results suggest that the constituents of titanium alloys reacted with the investment oxides and atmospheric oxygen to form external oxides due to the free energy of oxide formation and the concentration of each element on the metal surface.

  12. Titanium nanostructures for biomedical applications

    Science.gov (United States)

    Kulkarni, M.; Mazare, A.; Gongadze, E.; Perutkova, Š.; Kralj-Iglič, V.; Milošev, I.; Schmuki, P.; Iglič, A.; Mozetič, M.

    2015-02-01

    Titanium and titanium alloys exhibit a unique combination of strength and biocompatibility, which enables their use in medical applications and accounts for their extensive use as implant materials in the last 50 years. Currently, a large amount of research is being carried out in order to determine the optimal surface topography for use in bioapplications, and thus the emphasis is on nanotechnology for biomedical applications. It was recently shown that titanium implants with rough surface topography and free energy increase osteoblast adhesion, maturation and subsequent bone formation. Furthermore, the adhesion of different cell lines to the surface of titanium implants is influenced by the surface characteristics of titanium; namely topography, charge distribution and chemistry. The present review article focuses on the specific nanotopography of titanium, i.e. titanium dioxide (TiO2) nanotubes, using a simple electrochemical anodisation method of the metallic substrate and other processes such as the hydrothermal or sol-gel template. One key advantage of using TiO2 nanotubes in cell interactions is based on the fact that TiO2 nanotube morphology is correlated with cell adhesion, spreading, growth and differentiation of mesenchymal stem cells, which were shown to be maximally induced on smaller diameter nanotubes (15 nm), but hindered on larger diameter (100 nm) tubes, leading to cell death and apoptosis. Research has supported the significance of nanotopography (TiO2 nanotube diameter) in cell adhesion and cell growth, and suggests that the mechanics of focal adhesion formation are similar among different cell types. As such, the present review will focus on perhaps the most spectacular and surprising one-dimensional structures and their unique biomedical applications for increased osseointegration, protein interaction and antibacterial properties.

  13. Rifampicin-fosfomycin coating for cementless endoprostheses: antimicrobial effects against methicillin-sensitive Staphylococcus aureus (MSSA) and methicillin-resistant Staphylococcus aureus (MRSA).

    Science.gov (United States)

    Alt, Volker; Kirchhof, Kristin; Seim, Florian; Hrubesch, Isabelle; Lips, Katrin S; Mannel, Henrich; Domann, Eugen; Schnettler, Reinhard

    2014-10-01

    New strategies to decrease infection rates in cementless arthroplasty are needed, especially in the context of the growing incidence of methicillin-resistant Staphylococcus aureus (MRSA) infections. The purpose of this study was to investigate the antimicrobial activity of a rifampicin-fosfomycin coating against methicillin-sensitive Staphylococcus aureus (MSSA) and MRSA in a rabbit infection prophylaxis model. Uncoated or rifampicin-fosfomycin-coated K-wires were inserted into the intramedullary canal of the tibia in rabbits and contaminated with an inoculation dose of 10(5) or 10(6) colony-forming units of MSSA EDCC 5055 in study 1 and MRSA T6625930 in study 2, respectively. After 28days the animals were killed and clinical, histological and microbiological assessment, including pulse-field gel electrophoresis, was conducted. Positive culture growth in agar plate testing and/or clinical signs and/or histological signs were defined positive for infection. Statistical evaluation was performed using Fisher's exact test. Both studies showed a statistically significant reduction of infection rates for rifampicin-fosfomycin-coated implants compared to uncoated K-wires (P=0.015). In both studies none of the 12 animals that were treated with a rifampicin-fosfomycin-coated implant showed clinical signs of infection or a positive agar plate testing result. In both studies, one animal of the coating group showed the presence of sporadic bacteria with concomitant inflammatory signs in histology. The control groups in both studies exhibited an infection rate of 100% with clear clinical signs of infection and positive culture growth in all animals. In summary, the rifampicin-fosfomycin-coating showed excellent antimicrobial activity against both MSSA and MRSA, and therefore warrants further clinical testing.

  14. Cementless anatomical prosthesis for the treatment of 3-part and 4-part proximal humerus fractures: cadaver study and prospective clinical study with minimum 2 years followup

    Directory of Open Access Journals (Sweden)

    Obert Laurent

    2016-01-01

    Full Text Available Introduction: The purpose of this study was to evaluate the functional and radiological outcomes of a cementless, trauma-specific locked stem for 3- and 4-part proximal humeral fractures. Materials and methods: This study consisted of two parts: a cadaver study with 22 shoulders and a multicenter prospective clinical study of 23 fracture patients evaluated at least 2 years after treatment. In the cadaver study, the locked stem (HumelockTM, FX Solutions and its instrumentation were evaluated. In the clinical study, five senior surgeons at four different hospitals performed the surgical procedures. An independent surgeon evaluated the patients using clinical (Constant score, QuickDASH and radiological (X-rays, CT scans outcome measures. Results: The cadaver study allowed us to validate the height landmarks relative to the pectoralis major tendon. In the clinical study, at the review, abduction was 95° (60–160, forward flexion was 108° (70–160, external rotation (elbow at body was 34° (0–55, the QuickDASH was 31 (4.5–59, the overall Constant score was 54 (27–75, and the weighted Constant score was 76 (31.5–109. Discussion: This preliminary study of hemiarthroplasty (HA with a locked stem found results that were at least equivalent to published series. As all patients had at least a 2-year follow-up, integration of the locked stem did not cause any specific complications. These results suggest that it is possible to avoid using cement when hemiarthroplasty is performed for the humeral stem. This implant makes height adjustment and transosseous suturing of the tuberosities more reproducible.

  15. Midterm results of cementless primary total hip arthroplasty%生物型初次全髋关节置换术的中期随访结果

    Institute of Scientific and Technical Information of China (English)

    何平; 龚翰; 陈东峰; 卢伟杰

    2016-01-01

    目的:探讨生物型固定的全髋关节置换术中髋臼假体的中期临床疗效。方法回顾性分析紫金县人民医院骨科与广州医科大学附属第一医院骨科自2002年1月至2010年9月收治的194例(206髋)生物型全髋关节置换术病例,排除合并髋关节感染、恶性肿瘤、患肢神经肌肉疾病者,随访时间5~13年,平均8.9年,临床观察髋关节功能评分( Harris评分)、并发症、影像学检查评估假体稳定性,组间比较采用配对样本t检验,计量资料对比采用卡方检验,假体生存率采用Kaplan-Meier方法进行分析,以无菌性松动导致的假体翻修作为随访终点。结果共116例(126髋)获得完整随访。 Harris评分由术前的(50.3±13.2)分提高至末次随访时的(96.4±5.1)分,差异有统计学意义(t =3.124,P<0.001)。其中术后并发症包括无菌性松动(7例7髋)、脱位(3例3髋)、深静脉血栓(1例1髋)、异位骨化(11例11髋),手术部位浅表感染(3例3髋)。以无菌性松动导致的假体翻修作为随访终点,髋臼假体13年累计生存率为88%,股骨假体13年累计生存率为100%。结论全髋关节置换术生物型髋关节假体的中期生存率满意,并发症少,临床结果好。%Objective To evaluate the clinical and radiographic results of cementless primary total hip arthroplasty (THA) by a midterm follow-up.Methods A series of 194 patients (206 hips) who had undergone cementless primary THA from January 2002 to September 2010 were involved in this retrospective study .Those patients with history of hip infection , malignant tumor or neuromuscular diseases were excluded.The mean follow-up time was 8.9 years (range,5-13 years).Clinical outcomes were evaluated based on the Harris score .Complications were recorded and components loosening was assessed in the anterior posterior and lateral X-ray examinations of the hips .Paired T

  16. Plasma quench production of titanium from titanium tetrachloride

    Energy Technology Data Exchange (ETDEWEB)

    Sears, J.W.

    1994-10-01

    This project, Plasma Quench Production of Titanium from Titanium Tetrachloride, centers on developing a technique for rapidly quenching the high temperature metal species and preventing back reactions with the halide. The quenching technique chosen uses the temperature drop produced in a converging/diverging supersonic nozzle. The rapid quench provided by this nozzle prevents the back reaction of the halide and metal. The nature of the process produces nanosized particles (10 to 100 nm). The powders are collected by cyclone separators, the hydrogen flared, and the acid scrubbed. Aluminum and titanium powders have been produced in the laboratory-scale device at 1 gram per hour. Efforts to date to scale up this process have not been successful.

  17. Plasmonic titanium nitride nanostructures for perfect absorbers

    DEFF Research Database (Denmark)

    Guler, Urcan; Li, Wen-Wei; Kinsey, Nathaniel

    2013-01-01

    We propose a metamaterial based perfect absorber in the visible region, and investigate the performance of titanium nitride as an alternative plasmonic material. Numerical and experimental results reveal that titanium nitride performs better than gold as a plasmonic absorbing material...

  18. Lightweight Protective Coatings For Titanium Alloys

    Science.gov (United States)

    Wiedemann, Karl E.; Taylor, Patrick J.; Clark, Ronald K.

    1992-01-01

    Lightweight coating developed to protect titanium and titanium aluminide alloys and titanium-matrix composite materials from attack by environment when used at high temperatures. Applied by sol-gel methods, and thickness less than 5 micrometers. Reaction-barrier and self-healing diffusion-barrier layers combine to protect titanium alloy against chemical attack by oxygen and nitrogen at high temperatures with very promising results. Can be extended to protection of other environmentally sensitive materials.

  19. Anodic growth of titanium dioxide nanostructures

    DEFF Research Database (Denmark)

    2010-01-01

    Disclosed is a method of producing nanostructures of titanium dioxide (TiO 2 ) by anodisation of titanium (Ti) in an electrochemical cell, comprising the steps of: immersing a non-conducting substrate coated with a layer of titanium, defined as the anode, in an electrolyte solution...... an electrical contact to the layer of titanium on the anode, where the electrical contact is made in the electrolyte solution...

  20. 21 CFR 73.575 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.575 Section 73.575 Food and... ADDITIVES EXEMPT FROM CERTIFICATION Foods § 73.575 Titanium dioxide. (a) Identity. (1) The color additive titanium dioxide is synthetically prepared TiO2, free from admixture with other substances. (2)...

  1. 21 CFR 73.2575 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.2575 Section 73.2575 Food and... ADDITIVES EXEMPT FROM CERTIFICATION Cosmetics § 73.2575 Titanium dioxide. (a) Identity and specifications. The color additive titanium dioxide shall conform in identity and specifications to the...

  2. 21 CFR 73.1575 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.1575 Section 73.1575 Food and... ADDITIVES EXEMPT FROM CERTIFICATION Drugs § 73.1575 Titanium dioxide. (a) Identity and specifications. (1) The color additive titanium dioxide shall conform in identity and specifications to the...

  3. 40 CFR 180.1195 - Titanium dioxide.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Titanium dioxide. 180.1195 Section 180.1195 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS... Titanium dioxide. Titanium dioxide is exempted from the requirement of a tolerance for residues in or...

  4. 21 CFR 73.3126 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.3126 Section 73.3126 Food and... ADDITIVES EXEMPT FROM CERTIFICATION Medical Devices § 73.3126 Titanium dioxide. (a) Identity and specifications. The color additive titanium dioxide (CAS Reg. No. 13463-67-7), Color Index No. 77891,...

  5. The use of a modular titanium endoprosthesis in skeletal reconstructions after bone tumor resections: method presentation and analysis of 37 cases

    Directory of Open Access Journals (Sweden)

    Croci Alberto Tesconi

    2000-01-01

    Full Text Available We analyzed 37 patients who underwent segmental wide resection of bone tumors and reconstruction with a modular titanium endoprosthesis at the Orthopaedic Oncology Group, between 1992 and 1998. Twelve patients were male and 25 were female, with a mean age of 30 years (9 - 81. The mean follow-up was 14 months (2 - 48. The diagnoses were: osteosarcoma (14 cases, metastatic carcinoma (10, Ewing's sarcoma (4, giant cell tumor (4, malignant fibrous histiocytoma (3, chondrosarcoma (1, and aneurysmal bone cyst (1. Eleven articulated total knee, 8 partial proximal femur with bipolar acetabulum, 8 partial proximal humerus, 3 total femur, 2 partial proximal tibia, 2 diaphyseal femur, 2 diaphyseal humerus, and 1 total proximal femur with cementless acetabulum endoprosthesis implant procedures were done. The complications related to the procedure included: infection (5 cases, dislocation (3, module loosening (1, and ulnar nerve paresthesia (1. We used the following criteria for the clinical evaluation: presence of pain, range of motion, reconstruction stability, surgical and oncologic complications, and patient acceptance. The results were good in 56.8% of the cases, regular in 32.4% and poor in 10.8%.

  6. Photonuclear reactions on titanium isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Belyshev, S. S. [Moscow State University (Russian Federation); Dzhilavyan, L. Z. [Russian Academy of Sciences, Institute for Nuclear Research (Russian Federation); Ishkhanov, B. S.; Kapitonov, I. M. [Moscow State University (Russian Federation); Kuznetsov, A. A., E-mail: kuznets@depni.sinp.msu.ru; Orlin, V. N.; Stopani, K. A. [Moscow State University, Skobeltsyn Institute of Nuclear Physics (Russian Federation)

    2015-03-15

    The photodisintegration of titanium isotopes in the giant-dipole-resonance energy region is studied by the photon-activation method. Bremsstrahlung photons whose spectrum has the endpoint energy of 55 MeV is used. The yields and integrated cross sections are determined for photoproton reactions on the titanium isotopes {sup 47,48,49,50}Ti. The respective experimental results are compared with their counterparts calculated on the basis of the TALYS code and a combined photonucleon-reaction model. The TALYS code disregards the isospin structure of the giant dipole resonance and is therefore unable to describe the yield of photoproton reactions on the heavy titanium isotopes {sup 49,50}Ti.

  7. Adaptive mesh refinement in titanium

    Energy Technology Data Exchange (ETDEWEB)

    Colella, Phillip; Wen, Tong

    2005-01-21

    In this paper, we evaluate Titanium's usability as a high-level parallel programming language through a case study, where we implement a subset of Chombo's functionality in Titanium. Chombo is a software package applying the Adaptive Mesh Refinement methodology to numerical Partial Differential Equations at the production level. In Chombo, the library approach is used to parallel programming (C++ and Fortran, with MPI), whereas Titanium is a Java dialect designed for high-performance scientific computing. The performance of our implementation is studied and compared with that of Chombo in solving Poisson's equation based on two grid configurations from a real application. Also provided are the counts of lines of code from both sides.

  8. Effect of whitening toothpaste on titanium and titanium alloy surfaces.

    Science.gov (United States)

    Faria, Adriana Cláudia Lapria; Bordin, Angelo Rafael de Vito; Pedrazzi, Vinícius; Rodrigues, Renata Cristina Silveira; Ribeiro, Ricardo Faria

    2012-01-01

    Dental implants have increased the use of titanium and titanium alloys in prosthetic applications. Whitening toothpastes with peroxides are available for patients with high aesthetic requirements, but the effect of whitening toothpastes on titanium surfaces is not yet known, although titanium is prone to fluoride ion attack. Thus, the aim of the present study was to compare Ti-5Ta alloy to cp Ti after toothbrushing with whitening and conventional toothpastes. Ti-5Ta (%wt) alloy was melted in an arc melting furnace and compared with cp Ti. Disks and toothbrush heads were embedded in PVC rings to be mounted onto a toothbrushing test apparatus. A total of 260,000 cycles were carried out at 250 cycles/minute under a load of 5 N on samples immersed in toothpaste slurries. Surface roughness and Vickers microhardness were evaluated before and after toothbrushing. One sample of each material/toothpaste was analyzed by Scanning Electron Microscopy (SEM) and compared with a sample that had not been submitted to toothbrushing. Surface roughness increased significantly after toothbrushing, but no differences were noted after toothbrushing with different toothpastes. Toothbrushing did not significantly affect sample microhardness. The results suggest that toothpastes that contain and those that do not contain peroxides in their composition have different effects on cp Ti and Ti-5Ta surfaces. Although no significant difference was noted in the microhardness and roughness of the surfaces brushed with different toothpastes, both toothpastes increased roughness after toothbrushing.

  9. Highly porous NiCo2O4 Nanoflakes and nanobelts as anode materials for lithium-ion batteries with excellent rate capability.

    Science.gov (United States)

    Mondal, Anjon Kumar; Su, Dawei; Chen, Shuangqiang; Xie, Xiuqiang; Wang, Guoxiu

    2014-09-10

    Highly porous NiCo2O4 nanoflakes and nanobelts were synthesized by using a hydrothermal technique, followed by calcination of the NiCo2O4 precursors. The as-synthesized materials were analyzed by scanning electron microscopy, X-ray diffraction, transmission electron microscopy, and Brunauer-Emmett-Teller methods. The NiCo2O4 nanoflakes and nanobelts were applied as anode materials for lithium-ion batteries. Owing to the unique porous structural features, the NiCo2O4 nanoflakes and nanobelts exhibited high specific capacities of 1033 and 1056 mA h g(-1), respectively, and good cycling stability and rate capability. These exceptional electrochemical performances could be ascribed to the remarkable structural feature with a high surface area and void spaces within the surface of nanoflakes and nanobelts, which provide large contact areas between electrolyte and active materials for electrolyte diffusion and cushion the volume variation during the lithium-ion insertion/extraction process.

  10. Rapid synthesis of monodispersed highly porous spinel nickel cobaltite (NiCo{sub 2}O{sub 4}) electrode material for supercapacitors

    Energy Technology Data Exchange (ETDEWEB)

    Naveen, A. Nirmalesh, E-mail: nirmalesh.naveen@gmail.com; Selladurai, S. [Ionics Laboratory, Department of Physics, Anna University, Chennai-600025 (India)

    2015-06-24

    Monodispersed highly porous spinel nickel cobaltite electrode material was successfully synthesized in a short time using combustion technique. Single phase cubic nature of the spinel nickel cobaltite with average crystallite size of 24 nm was determined from X-ray diffraction study. Functional groups present in the compound were determined from FTIR study and it further confirms the spinel formation. FESEM images reveal the porous nature of the prepared material and uniform size distribution of the particles. Electrochemical evaluation was performed using Cyclic Voltammetry (CV) technique, Chronopotentiometry (CP) and Electrochemical Impedance Spectroscopy (EIS). Results reveal the typical pseudocapacitive behaviour of the material. Maximum capacitance of 754 F/g was calculated at the scan rate of 5 mV/s, high capacitance was due to the unique porous morphology of the electrode. Nyquist plot depicts the low resistance and good electrical conductivity of nickel cobaltite. It has been found that nickel cobaltite prepared by this typical method will be a potential electrode material for supercapcitor application.

  11. Synthesis of nano-particle and highly porous conducting perovskites from simple in situ sol–gel derived carbon templating process

    Indian Academy of Sciences (India)

    Wei Zhou; Ran Ran; Zongping Shao; Wanqin Jin; Nanping Xu

    2010-08-01

    Nano-sized La0.6Sr0.4Co0.2Fe0.8O$_{3–\\delta}$ (LSCF) and La0.8Sr0.2MnO$_{3–\\delta}$ (LSM) oxides were synthesized by a simple in situ sol–gel derived carbon templating process. Nano-sized LSCF–carbon and LSM–carbon composites were first obtained with a grain size of 20–30 nm. Further calcination of the obtained composites under air resulted in the nano-sized pure-phase perovskites with crystalline size of as small as 14 nm. Such a decrease in crystalline size of perovskite via the indirect calcination process was ascribed to the suppressing effect of carbon in the grain growth of perovskite. Furthermore, when the in situ created carbon was applied as a template for pore forming, a highly porous perovskite sintering body packing from the nano-sized perovskite oxide was obtained.

  12. An X-ray absorption spectroscopy study of the inversion degree in zinc ferrite nanocrystals dispersed on a highly porous silica aerogel matrix.

    Science.gov (United States)

    Carta, D; Marras, C; Loche, D; Mountjoy, G; Ahmed, S I; Corrias, A

    2013-02-07

    The structural properties of zinc ferrite nanoparticles with spinel structure dispersed in a highly porous SiO(2) aerogel matrix were compared with a bulk zinc ferrite sample. In particular, the details of the cation distribution between the octahedral (B) and tetrahedral (A) sites of the spinel structure were determined using X-ray absorption spectroscopy. The analysis of both the X-ray absorption near edge structure and the extended X-ray absorption fine structure indicates that the degree of inversion of the zinc ferrite spinel structures varies with particle size. In particular, in the bulk microcrystalline sample, Zn(2+) ions are at the tetrahedral sites and trivalent Fe(3+) ions occupy octahedral sites (normal spinel). When particle size decreases, Zn(2+) ions are transferred to octahedral sites and the degree of inversion is found to increase as the nanoparticle size decreases. This is the first time that a variation of the degree of inversion with particle size is observed in ferrite nanoparticles grown within an aerogel matrix.

  13. Nanodispersed boriding of titanium alloy

    Directory of Open Access Journals (Sweden)

    Kateryna O. Kostyk

    2015-12-01

    Full Text Available The problem of improving the operational reliability of machines is becoming increasingly important due to the increased mechanical, thermal and other loads on the details. There are many surface hardening methods for machines parts which breakdown begins with surface corruption. The most promising methods are chemo-thermal treatment. Aim: The aim of this work is to study the impact of boriding on the structure and properties of titanium alloy. Materials and Methods: The material of this study is VT3-1 titanium alloy. The boriding were conducted using nanodispersed powder blend based on boric substances. Results: It is established that boriding of paste compounds allows obtaining the surface hardness within 30...29 GPa and with declining to 27...26 GPa in layer to the transition zone (with total thickness up to 110 μm owing to changes of the layer phase composition where Ti2B, TiB, TiB2 titanium borides are formed. The increasing of chemical-thermal treatment time from 15 minutes to 2 hours leads to thickening of the borated layer (30...110 µm and transition zone (30...190 µm. Conclusions: Due to usage of nanodispersed boric powder, the boriding duration is decreasing in 2...3 times. This allows saving time and electric energy. The developed optimal mode of boriding the VT3-1 titanium alloy allows obtaining the required operational characteristics and to combine the saturation of the surface layer with atomic boron and hardening.

  14. Increased chondrocyte adhesion on nanotubular anodized titanium.

    Science.gov (United States)

    Burns, Kevin; Yao, Chang; Webster, Thomas J

    2009-03-01

    Previous studies have demonstrated increased osteoblast (bone-forming cells) functions (including adhesion, synthesis of intracellular collagen, alkaline phosphatase activity, and deposition of calcium-containing minerals) on titanium anodized to possess nanometer features compared with their unanodized counterparts. Such titanium materials were anodized to possess novel nanotubes also capable of drug delivery. Since titanium has not only experienced wide spread commercial use in orthopedic but also in cartilage applications, the objective of the present in vitro study was for the first time to investigate chondrocyte (cartilage synthesizing cells) functions on titanium anodized to possess nanotubes. For this purpose, titanium was anodized in dilute hydrofluoric acid at 20 V for 20 min. Results showed increased chondrocyte adhesion on anodized titanium with nanotube structures compared with unanodized titanium. Importantly, the present study also provided evidence why. Since material characterization studies revealed significantly greater nanometer roughness and similar chemistry as well as crystallinity between nanotubular anodized and unanodized titanium, the results of the present study highlight the importance of the nanometer roughness provided by anodized nanotubes on titanium for enhancing chondrocyte adhesion. In this manner, the results of the present in vitro study indicated that anodization might be a promising quick and inexpensive method to modify the surface of titanium-based implants to induce better chondrocyte adhesion for cartilage applications.

  15. Highly porous ionic rht metal-organic framework for H2 and CO2 storage and separation: A molecular simulation study

    KAUST Repository

    Babarao, Ravichandar

    2010-07-06

    The storage and separation of H2 and CO2 are investigated in a highly porous ionic rht metal-organic framework (rht-MOF) using molecular simulation. The rht-MOF possesses a cationic framework and charge-balancing extraframework NO3 - ions. Three types of unique open cages exist in the framework: rhombicuboctahedral, tetrahedral, and cuboctahedral cages. The NO3 - ions exhibit small mobility and are located at the windows connecting the tetrahedral and cuboctahedral cages. At low pressures, H2 adsorption occurs near the NO 3 - ions that act as preferential sites. With increasing pressure, H2 molecules occupy the tetrahedral and cuboctahedral cages and the intersection regions. The predicted isotherm of H2 at 77 K agrees well with the experimental data. The H2 capacity is estimated to be 2.4 wt % at 1 bar and 6.2 wt % at 50 bar, among the highest in reported MOFs. In a four-component mixture (15:75:5:5 CO2/H 2/CO/CH4) representing a typical effluent gas of H 2 production, the selectivity of CO2/H2 in rht-MOF decreases slightly with increasing pressure, then increases because of cooperative interactions, and finally decreases as a consequence of entropy effect. By comparing three ionic MOFs (rht-MOF, soc-MOF, and rho-ZMOF), we find that the selectivity increases with increasing charge density or decreasing free volume. In the presence of a trace amount of H2O, the interactions between CO2 and NO3 - ions are significantly shielded by H2O; consequently, the selectivity of CO 2/H2 decreases substantially. © 2010 American Chemical Society.

  16. Highly porous PEM fuel cell cathodes based on low density carbon aerogels as Pt-support: Experimental study of the mass-transport losses

    Science.gov (United States)

    Marie, Julien; Chenitz, Regis; Chatenet, Marian; Berthon-Fabry, Sandrine; Cornet, Nathalie; Achard, Patrick

    Carbon aerogels exhibiting high porous volumes and high surface areas, differentiated by their pore-size distributions were used as Pt-supports in the cathode catalytic layer of H 2/air-fed PEM fuel cell. The cathodes were tested as 50 cm 2 membrane electrode assemblies (MEAs). The porous structure of the synthesized catalytic layers was impacted by the nanostructure of the Pt-doped carbon aerogels (Pt/CAs). In this paper thus we present an experimental study aiming at establishing links between the porous structure of the cathode catalytic layers and the MEAs performances. For that purpose, the polarization curves of the MEAs were decomposed in 3 contributions: the kinetic loss, the ohmic loss and the mass-transport loss. We showed that the MEAs made with the different carbon aerogels had similar kinetic activities (low current density performance) but very different mass-transport voltage losses. It was found that the higher the pore-size of the initial carbon aerogel, the higher the mass-transport voltage losses. Supported by our porosimetry (N 2-adsorption and Hg-porosimetry) measurement, we interpret this apparent contradiction as the consequence of the more important Nafion penetration into the carbon aeorogel with larger pore-size. Indeed, the catalytic layers made from the larger pore-size carbon aerogel had lower porosities. We thus show in this work that carbon aerogels are materials with tailored nanostructured structure which can be used as model materials for experimentally testing the optimization of the PEM fuel cell catalytic layers.

  17. Antimicrobial titanium/silver PVD coatings on titanium

    Directory of Open Access Journals (Sweden)

    Thull Roger

    2006-03-01

    Full Text Available Abstract Background Biofilm formation and deep infection of endoprostheses is a recurrent complication in implant surgery. Post-operative infections may be overcome by adjusting antimicrobial properties of the implant surface prior to implantation. In this work we described the development of an antimicrobial titanium/silver hard coating via the physical vapor deposition (PVD process. Methods Coatings with a thickness of approximately 2 μm were deposited on titanium surfaces by simultaneous vaporisation of both metals in an inert argon atmosphere with a silver content of approximately 0.7 – 9% as indicated by energy dispersive X-ray analysis. On these surfaces microorganisms and eukaryotic culture cells were grown. Results The coatings released sufficient silver ions (0.5–2.3 ppb when immersed in PBS and showed significant antimicrobial potency against Staphylococcus epidermis and Klebsiella pneumoniae strains. At the same time, no cytotoxic effects of the coatings on osteoblast and epithelial cells were found. Conclusion Due to similar mechanical performance when compared to pure titanium, the TiAg coatings should be suitable to provide antimicrobial activity on load-bearing implant surfaces.

  18. Hydrogen content in titanium and a titanium-zirconium alloy after acid etching.

    Science.gov (United States)

    Frank, Matthias J; Walter, Martin S; Lyngstadaas, S Petter; Wintermantel, Erich; Haugen, Håvard J

    2013-04-01

    Dental implant alloys made from titanium and zirconium are known for their high mechanical strength, fracture toughness and corrosion resistance in comparison with commercially pure titanium. The aim of the study was to investigate possible differences in the surface chemistry and/or surface topography of titanium and titanium-zirconium surfaces after sand blasting and acid etching. The two surfaces were compared by X-ray photoelectron spectroscopy, secondary ion mass spectroscopy, scanning electron microscopy and profilometry. The 1.9 times greater surface hydrogen concentration of titanium zirconium compared to titanium was found to be the major difference between the two materials. Zirconium appeared to enhance hydride formation on titanium alloys when etched in acid. Surface topography revealed significant differences on the micro and nanoscale. Surface roughness was increased significantly (pzirconium alloy. High-resolution images showed nanostructures only present on titanium zirconium.

  19. Gait analysis after total knee arthroplasty with cemented versus cementless type%骨水泥型与非骨水泥型全膝关节置换后的步态差异

    Institute of Scientific and Technical Information of China (English)

    张旻; 江澜; 沈晓艳

    2011-01-01

    背景:全膝关节置换已经被证明是一种有效治疗膝骨性关节炎的方法,但是不同类型的全膝关节置换假体固定方式术后所产生的膝关节下肢生物力学差异至今仍不明确.目的:通过三维步态分析骨水泥固定和非骨水泥固定两种不同的全膝关节置换术后患者的膝关节生物力学差异.方法:分别选取骨水泥型全膝关节置换以及非骨水泥型全膝关节置换患者各16例,通过测力台以及三维步态分析系统比较2组患者术前以及术后3个月的膝关节生物力学变化并进行对比.结果与结论:与手术前相比两组患者术后步速及步长均明显增加,支撑相在整个步态周期中的百分比明显减小, 膝关节屈在支撑相及摆动相中最大屈曲角度均明显增加,膝关节外翻角度增加.两种患者术后膝关节内翻角度以及膝关节内收力矩均明显减小.提示,骨水泥型与非骨水泥型全膝关节置换术均能有效改善膝骨性关节炎患者的步行能力以及下肢关节功能,两者间未见明显生物力学差异.%BACKGROUND: Total knee arthroplasty (TKA) has been proved to be a very effective method for patients with knee osteoarthritis. But the biomedical changes at knee joint between two different types of TKA (cemented and cementless) after operation remain not clear.OBJECTIVE: To explore the different biomechanical changes between the cemented and cementless TKA through three-dimensional gait analysis.METHODS: A total of 16 knee osteoarthritis patients treated with cemented TKA and 16 with cementless TKA were included.Force plates and three-dimensional gait analysis system were used to compare differences in biomechanics before and 3 months after operations.RESULTS AND CONCLUSION: Both groups showed significant increased walking speed and stride length, but decreased percentage of stance phase in gait cycle after operation, significant increased knee flexion angle in stance phase and swing

  20. Carbon nanotube-based coatings on titanium

    Indian Academy of Sciences (India)

    Elzbieta Dlugon; Wojciech Simka; Aneta Fraczek-Szczypta; Wiktor Niemiec; Jaroslaw Markowski; Marzena Szymanska; Marta Blazewicz

    2015-09-01

    This paper reports results of the modification of titanium surface with multiwalled carbon nanotubes (CNTs). The Ti samples were covered with CNTs via electrophoretic deposition (EPD) process. Prior to EPD process, CNTs were functionalized by chemical treatment. Mechanical, electrochemical and biological properties of CNT-covered Ti samples were studied and compared to those obtained for unmodified titanium surface. Atomic force microscopy was used to investigate the surface topography. To determine micromechanical characteristics of CNT-covered metallic samples indentation tests were conducted. Throughout electrochemical studies were performed in order to characterize the impact of the coating on the corrosion of titanium substrate. In vitro experiments were conducted using the human osteoblast NHOst cell line. CNT layers shielded titanium from corrosion gave the surface-enhanced biointegrative properties. Cells proliferated better on the modified surface in comparison to unmodified titanium. The deposited layer enhanced cell adhesion and spreading as compared to titanium sample.

  1. Brazing titanium structures. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Pressly, H.B.

    1977-03-01

    A vacuum furnace brazing process using Ag-5A1-0.5Mn brazing alloy has been developed for joining titanium alloy Ti-6Al-4V structures. Lap-shear strengths of the braze joints and the effects of the brazing thermal cycle on the tensile and bending properties of mill-annealed Ti-6Al-4V alloy sheet are reported. Nondestructive test methods were evaluated for detecting defects in these braze joints.

  2. Investigation of Infiltrated and Sintered Titanium Carbide

    Science.gov (United States)

    1952-04-01

    taneive investigations in this field during the ’time preceding this contract, and concentrated their effort® On titanium carbide as the’ refractospy...component • The Basic work of this investigation consisted of? X, KpälfiCÄVtloh and refinement of cOmätrcial grades of titanium carbide hj...facilitate a comparison between the different methods» an investigation was then carried out with composite bodies* consisting of titanium carbide asd

  3. Production of titanium from ilmenite: a review

    Energy Technology Data Exchange (ETDEWEB)

    Kohli, R.

    1981-12-01

    The general principles for beneficiation of titanium ores are reviewed and the specific processes used in individual units in various countries are discussed. This is followed by a critical evaluation of various current and potential reduction methods for the production of titanium metal from the processed concentrates. Finally, the report outlines a research program for the development of a commercially viable alternative method for the production of titanium metal.

  4. A New Construction Material-Titanium

    Science.gov (United States)

    1974-01-01

    the Academy of Sciences of the Georgian SSR resulted in important proposals for the pro- duction of gallic acid and other preparations. AT-3 tita’ 4um...titanium with various elements, looks at phase transformation in certain alloy systems~and separateI alloys used in Industry. The articles give the...titanium alloys. Questions of the use of titanium and its alloys in various areas of the national econcmy are given. The work was written for scientists

  5. Titanium alloys Russian aircraft and aerospace applications

    CERN Document Server

    Moiseyev, Valentin N

    2005-01-01

    This text offers previously elusive information on state-of-the-art Russian metallurgic technology of titanium alloys. It details their physical, mechanical, and technological properties, as well as treatments and applications in various branches of modern industry, particularly aircraft and aerospace construction. Titanium Alloys: Russian Aircraft and Aerospace Applications addresses all facets of titanium alloys in aerospace and aviation technology, including specific applications, fundamentals, composition, and properties of commercial alloys. It is useful for all students and researchers interested in the investigation and applications of titanium.

  6. 2005 Xi'an International Titanium Conference

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    @@ First Circular Call for Papers In the 98' Xi'an International Titanium Conference (XITC'98), more than 300 representatives of the research and industry circles from 12 countries were gathered in Xi'an to exchange the new progress on titanium R&D and industrialization. XITC'98played an important role in promoting titanium R&D for the world, especially for China. In order to let the people engaged in titanium industry know more Chinese and the world titanium industry, promote the exchange and cooperation of the world titanium circle, we decide to hold the 2005 Xi'an International titanium Conference (XITC'05), which will be held on October 16~19, 2005 in Xi'an, China. The conference will provide a forum on the exchange and discussion of new ideas and achievements related to the aspects of titanium technology and industry in recent years. At the same time, the 12th China National Conference on Titanium will be held on October 19~23, 2005 in the same place after XITC'05.

  7. Appcelerator Titanium patterns and best practices

    CERN Document Server

    Pollentine, Boydlee

    2013-01-01

    The book takes a step-by-step approach to help you understand CommonJS and Titanium architecture patterns, with easy to follow samples and plenty of in-depth explanations If you're an existing Titanium developer or perhaps a new developer looking to start off your Titanium applications "the right way", then this book is for you. With easy to follow examples and a full step-by-step account of architecting a sample application using CommonJS and MVC, along with chapters on new features such as ACS, you'll be implementing enterprise grade Titanium solutions in no time. You should have some JavaSc

  8. Titanium Matrix Composite Pressure Vessel Project

    Data.gov (United States)

    National Aeronautics and Space Administration — For over 15 years, FMW Composite Systems has developed Metal Matrix Composite manufacturing methodologies for fabricating silicon-carbide-fiber-reinforced titanium...

  9. Impaction grafting in the femur in cementless modular revision total hip arthroplasty: a descriptive outcome analysis of 243 cases with the MRP-TITAN revision implant

    Directory of Open Access Journals (Sweden)

    Wimmer Matthias D

    2013-01-01

    .1% after 8.7 years]. Radiologic evaluation showed no significant change in axial implant migration (4.3% vs. 9.3%; p = 0.19 but a significant reduction in proximal stress shielding (5.7% vs. 17.9%; p  Conclusion We present the largest analysis of the impaction grafting technique in combination with cementless distal diaphyseal stem fixation published so far. Our data provides initial evidence of improved bone regeneration after graft augmentation of metaphyseal bone defects. The data suggests that proximal metaphyseal graft augmentation is beneficial for large metaphyseal bone defects (Paprosky types IIC and III and stem diameters of 17 mm and above. Due to the limitations of a retrospective and descriptive study the level of evidence remains low and prospective trials should be conducted.

  10. [Experimental research on porcelain fused to the surface of pure titanium and titanium alloys].

    Science.gov (United States)

    Wang, D; Ai, S; Xu, J

    1995-07-01

    Titanium material has been widely used in prosthodontics since the end of 1980s. However, the research on porcelain fused to the surfaces of titanium material was quite few. This article introduced the technological process of low-fusing dental porcelain--Ceratin fused to pure titanium and titanium alloys. The values of the bond strength of Ceratin and titanium substrates were obtained by shearing test with INSTRON Model-1185. The average value of the shearing strength between TA2 and Ceratin was 31. 01MPa. The corresponding value between TC4 and Ceratin was 33.73MPa. The interface between Ceratin and titanium substrate was observed with scanning electron microscope (SEM). The results of this research proposed that it is hopeful that Ceratin is used as special procelain with titanium material.

  11. Appcelerator Titanium business application development cookbook

    CERN Document Server

    Bahrenberg, Benjamin

    2013-01-01

    Presented in easy to follow, step by step recipes, this guide is designed to lead you through the most important aspects of application design.Titanium developers who already have a basic knowledge of working with Appcelerator Titanium but want to further develop their knowledge for use with business applications

  12. Titanium tetrachloride burns to the eye.

    OpenAIRE

    Chitkara, D K; McNeela, B. J.

    1992-01-01

    We present eight cases of chemical burns of the eyes from titanium tetrachloride, an acidic corrosive liquid. However it causes severe chemical burns which have a protracted course and features more akin to severe alkali burns. Injuries related to titanium tetrachloride should be treated seriously and accordingly appropriate management is suggested.

  13. Titanium Carbide Bipolar Plate for Electrochemical Devices

    Energy Technology Data Exchange (ETDEWEB)

    LaConti, Anthony B.; Griffith, Arthur E.; Cropley, Cecelia C.; Kosek, John A.

    1998-05-08

    Titanium carbide comprises a corrosion resistant, electrically conductive, non-porous bipolar plate for use in an electrochemical device. The process involves blending titanium carbide powder with a suitable binder material, and molding the mixture, at an elevated temperature and pressure.

  14. Wettability studies of topologically distinct titanium surfaces.

    Science.gov (United States)

    Kulkarni, Mukta; Patil-Sen, Yogita; Junkar, Ita; Kulkarni, Chandrashekhar V; Lorenzetti, Martina; Iglič, Aleš

    2015-05-01

    Biomedical implants made of titanium-based materials are expected to have certain essential features including high bone-to-implant contact and optimum osteointegration, which are often influenced by the surface topography and physicochemical properties of titanium surfaces. The surface structure in the nanoscale regime is presumed to alter/facilitate the protein binding, cell adhesion and proliferation, thereby reducing post-operative complications with increased lifespan of biomedical implants. The novelty of our TiO2 nanostructures lies mainly in the high level control over their morphology and roughness by mere compositional change and optimisation of the experimental parameters. The present work focuses on the wetting behaviour of various nanostructured titanium surfaces towards water. Kinetics of contact area of water droplet on macroscopically flat, nanoporous and nanotubular titanium surface topologies was monitored under similar evaporation conditions. The contact area of the water droplet on hydrophobic titanium planar surface (foil) was found to decrease during evaporation, whereas the contact area of the droplet on hydrophobic nanorough titanium surfaces practically remained unaffected until the complete evaporation. This demonstrates that the surface morphology and roughness at the nanoscale level substantially affect the titanium dioxide surface-water droplet interaction, opposing to previous observations for microscale structured surfaces. The difference in surface topographic nanofeatures of nanostructured titanium surfaces could be correlated not only with the time-dependency of the contact area, but also with time-dependency of the contact angle and electrochemical properties of these surfaces.

  15. Stress-corrosion cracking of titanium alloys.

    Science.gov (United States)

    Blackburn, M. J.; Feeney, J. A.; Beck, T. R.

    1973-01-01

    In the light of research material published up to May 1970, the current understanding of the experimental variables involved in the stress-corrosion cracking (SCC) behavior of titanium and its alloys is reviewed. Following a brief summary of the metallurgy and electrochemistry of titanium alloys, the mechanical, electrochemical, and metallurgical parameters influencing SCC behavior are explored with emphasis on crack growth kinetics. Macro- and microfeatures of fractures are examined, and it is shown that many transgranular SCC failures exhibit morphological and crystallographic features similar to mechanical cleavage failures. Current SCC models are reviewed with respect to their ability to explain the observed SCC behavior of titanium and its alloys. Possible methods for eliminating or minimizing stress corrosion hazards in titanium or titanium alloy components are described.

  16. [Use of titanium alloys for medical instruments].

    Science.gov (United States)

    Feofilov, R N; Chirkov, V K; Levin, M V

    1977-01-01

    On the ground of an analysis into properties of titanium and its alloys the fields of their possible utilization for making various medical instruments are proposed. Because of their insufficient hardness and wear-resistance the titanium alloys cannot be recommended for making medical instruments with thin cutting edges. For the reasons of their insufficient strength, low wear-resistance and substandard modulus of elasticity, it is inexpedient to use titanium alloys in making many types of clamping medical instruments. Nor is it advisable to employ titanium alloys in handles of the instruments, for this may lead to a contact corrosion of their working parts. The use of titanium alloys is recommended for making bone-joining members, retracting medical instruments, of the spatula and speculum types, some kinds of non-magnetic pincers and ultrasonic medical instruments.

  17. Welding and Joining of Titanium Aluminides

    Directory of Open Access Journals (Sweden)

    Jian Cao

    2014-06-01

    Full Text Available Welding and joining of titanium aluminides is the key to making them more attractive in industrial fields. The purpose of this review is to provide a comprehensive overview of recent progress in welding and joining of titanium aluminides, as well as to introduce current research and application. The possible methods available for titanium aluminides involve brazing, diffusion bonding, fusion welding, friction welding and reactive joining. Of the numerous methods, solid-state diffusion bonding and vacuum brazing have been most heavily investigated for producing reliable joints. The current state of understanding and development of every welding and joining method for titanium aluminides is addressed respectively. The focus is on the fundamental understanding of microstructure characteristics and processing–microstructure–property relationships in the welding and joining of titanium aluminides to themselves and to other materials.

  18. Early follow-up of total hip arthroplasty with Accolade TMZF cementless femoral prosthesis%Accolade TMZF生物型股骨假体用于全髋置换的早期随访

    Institute of Scientific and Technical Information of China (English)

    朱永生; 徐耀增; 朱锋; 吴广鹏; 邵洪国

    2015-01-01

    BACKGROUND:Compared with the fixation of bone cement prosthesis,the fixation of cementless femoral prosthesis does not have the folowing worries,including cement-prosthesis separation,cement sheath rupture,and cement debris-induced osteolysis.Long-term outcomes are good,and the survival rate is high.OBJECTIVE: To observe the preliminary clinical results and complications of total hip arthroplasty with Accolade TMZF cementless femoral stem.METHODS:From February 2010 to July 2012,67 patients (70 hips) underwent primary total hip arthroplasty with cementless femoral stem.Al patients were treated with Accolade TMZF Biological hip prosthesis system.Femoral component was treated with the same Accolade TMZF cementless femoral stem.Acetabular component was treated with Secure-fit HA and Trident PSL HA.The first mortar joint friction surface was treated withceramic-ceramic composite in 49 hips,ceramic-polyethylene composite in 19 hips and metal-polyethylene composite in 2 hips.After replacement,hip imaging data were utilized to assess biological fixation of femoral stem prosthesis,osteolysis surrounding the prosthesis,and prosthesis subsidence,and to observe hip function,thigh pain and complications.RESULTS AND CONCLUSION:Al cases were folowed up for more than 2 years.The mean Harris hip score was (32.7±6.2) preoperatively,and improved to (89.2±5.1) during final folow-up.During final folow-up,four patients (6%) suffered from slight pain.No moderate and severe pain or extremely severe pain occurred.None of the patients needed second operation due to failure for various reasons.X-ray films showed that no prosthesis displacement or loosening.Bone fixation surrounding the prosthesis was visible at the femoral side.Only one hip had subsidence of less than 2 mm,and the remaining did not experience subsidence.No blood vessels or nerve injury appeared during the surgery.During prosthesis placement,femoral calcar cleavage fracture occurred in 4 hips,so wire cerclage was used

  19. Synthesis and physicochemical characterization of titanium oxide and sulfated titanium oxide obtained by thermal hydrolysis of titanium tetrachloride

    Directory of Open Access Journals (Sweden)

    H. Esteban Benito

    2014-09-01

    Full Text Available This work reports the synthesis of titanium oxide (TiO2 and sulfated titanium oxide (TiO2-SO4(2- obtained by thermal hydrolysis of titanium tetrachloride. Titanium hydroxide synthesized by this method was impregnated with a 1 N H2SO4 solution, to give amounts of sulfate ions (SO4(2- of 3 and 7 wt%. The synthesized samples were dried at 120 °C during 24 h and then calcined for 3 h at 400 °C. Thermal analyses, X-ray diffraction, nitrogen physisorption, infrared spectroscopy, potentiometric titration with n-butylamine, U.V.-visible diffuse reflectance spectroscopy and scanning electron microscopy were used to characterize the materials. The results of physicochemical characterization revealed that a mixture of crystalline structures, anatase, brookite and rutile developed in the titanium oxide, stabilizing the anatase structure in the sulfated titanium oxides, and coexisting with a small amount of brookite structure. The synthesized mesoporous materials developed specific surface areas between 62 and 70 m² g-1, without detecting an important influence of sulfation on this parameter. The presence of sulfate ions improved the acidity of titanium oxide and modified the characteristics of light absorption in the 425-600 nm region, which suggests the possibility of using these materials in reactions assisted by visible light.

  20. Characterisation of titanium-titanium boride composites processed by powder metallurgy techniques

    Energy Technology Data Exchange (ETDEWEB)

    Selva Kumar, M., E-mail: sel_mcet@yahoo.co.in [Department of Mechanical Engineering, Dr. Mahalingam College of Engineering and Technology, Pollachi-642003 (India); Chandrasekar, P.; Chandramohan, P. [School of Engineering, Professional Group of Institutions, Coimbatore-641662 (India); Mohanraj, M. [Department of Mechanical Engineering, Info Institute of Engineering, Coimbatore-641107 (India)

    2012-11-15

    In this work, a detailed characterisation of titanium-titanium boride composites processed by three powder metallurgy techniques, namely, hot isostatic pressing, spark plasma sintering and vacuum sintering, was conducted. Two composites with different volume percents of titanium boride reinforcement were used for the investigation. One was titanium with 20% titanium boride, and the other was titanium with 40% titanium boride (by volume). Characterisation was performed using X-ray diffraction, electron probe micro analysis - energy dispersive spectroscopy and wavelength dispersive spectroscopy, image analysis and scanning electron microscopy. The characterisation results confirm the completion of the titanium boride reaction. The results reveal the presence of titanium boride reinforcement in different morphologies such as needle-shaped whiskers, short agglomerated whiskers and fine plates. The paper also discusses how mechanical properties such as microhardness, elastic modulus and Poisson's ratio are influenced by the processing techniques as well as the volume fraction of the titanium boride reinforcement. - Highlights: Black-Right-Pointing-Pointer Ti-TiB composites were processed by HIP, SPS and vacuum sintering. Black-Right-Pointing-Pointer The completion of Ti-TiB{sub 2} reaction was confirmed by XRD, SEM and EPMA studies. Black-Right-Pointing-Pointer Hardness and elastic properties of Ti-TiB composites were discussed. Black-Right-Pointing-Pointer Processing techniques were compared with respect to their microstructure.

  1. Titanium in Engine Valve Systems

    Science.gov (United States)

    Allison, J. E.; Sherman, A. M.; Bapna, M. R.

    1987-03-01

    Titanium alloys offer a unique combination of high strength-to-weight ratio, good corrosion resistance and favorable high temperature mechanical properties. Still, their relatively high cost has discouraged consideration for widespread use in automotive components. Recent demands for increased fuel economy have led to the consideration of these alloys for use as valve train materials where higher costs might be offset by improvements in performance and fuel economy. Lighter weight valve train components permit the use of lower spring loads, thus reducing friction and increasing fuel economy. Camshaft friction measurements made on a typical small displacement engine indicate that a twoto-four percent increase in fuel economy can be achieved. Valve train components are, however, subject to a severe operating environment, including elevated temperatures, sliding wear and high mechanical loads. This paper discusses the details of alloy and heat treatment selection for optimizing valve performance. When properly manufactured, titanium valves have been shown to withstand very stringent durability testing, indicating the technical feasibility of this approach to fuel economy improvement.

  2. Selection of crucible oxides in molten titanium and titanium aluminum alloys by thermo-chemistry calculations

    Directory of Open Access Journals (Sweden)

    Kostov A.

    2005-01-01

    Full Text Available Titanium and its alloys interstitially dissolve a large amount of impurities such as oxygen and nitrogen, which degrade the mechanical and physical properties of alloys. On the other hand crucible oxides based on CaO, ZrO2 Y2O3, etc., and their spinels (combination of two or more oxides can be used for melting titanium and its alloys. However, the thermodynamic behavior of calcium, zirconium, yttrium on the one side, and oxygen on the other side, in molten Ti and Ti-Al alloys have not been made clear and because of that, it is very interesting for research. Owing of literature data, as well as these crucibles are cheaper than standard crucibles for melting titanium and titanium alloys, in this paper will be presented the results of selection of thermo-chemistry analysis with the aim to determine the crucible oxide stability in contact with molten titanium and titanium-aluminum alloys.

  3. Current assisted superplastic forming of titanium alloy

    Directory of Open Access Journals (Sweden)

    Wang Guofeng

    2015-01-01

    Full Text Available Current assisted superplastic forming combines electric heating technology and superplastic forming technology, and can overcome some shortcomings of traditional superplastic forming effectively, such as slow heating rate, large energy loss, low production efficiency, etc. Since formability of titanium alloy at room temperature is poor, current assisted superplastic forming is suitable for titanium alloy. This paper mainly introduces the application of current assisted superplastic forming in the field of titanium alloy, including forming technology of double-hemisphere structure and bellows.

  4. Stress corrosion cracking of titanium alloys

    Science.gov (United States)

    Statler, G. R.; Spretnak, J. W.; Beck, F. H.; Fontana, M. G.

    1974-01-01

    The effect of hydrogen on the properties of metals, including titanium and its alloys, was investigated. The basic theories of stress corrosion of titanium alloys are reviewed along with the literature concerned with the effect of absorbed hydrogen on the mechanical properties of metals. Finally, the basic modes of metal fracture and their importance to this study is considered. The experimental work was designed to determine the effects of hydrogen concentration on the critical strain at which plastic instability along pure shear directions occurs. The materials used were titanium alloys Ti-8Al-lMo-lV and Ti-5Al-2.5Sn.

  5. Titanium exposure and yellow nail syndrome

    Directory of Open Access Journals (Sweden)

    Ali Ataya

    2015-01-01

    Full Text Available Yellow nail syndrome is a rare disease of unclear etiology. We describe a patient who develops yellow nail syndrome, with primary nail and sinus manifestations, shortly after amalgam dental implants. A study of the patient's nail shedding showed elevated nail titanium levels. The patient had her dental implants removed and had complete resolution of her sinus symptoms with no change in her nail findings. Since the patient's nail findings did not resolve we do not believe titanium exposure is a cause of her yellow nail syndrome but perhaps a possible relationship exists between titanium exposure and yellow nail syndrome that requires further studies.

  6. Low-valent pentafulvene titanium dinitrogen complex as a precursor for cationic titanium complexes

    NARCIS (Netherlands)

    Scherer, Axel; Haase, Detlev; Saak, Wolfgang; Beckhaus, Ruediger; Meetsma, Auke; Bouwkamp, Marco W.; Beckhaus, Rüdiger

    2009-01-01

    Treatment of titanium dinitrogen complex [Cp*(eta(6)-C(5)H(4)=C(10)H(14))Ti](2)(mu-N(2)) (1) with ferrocenium borate, [Cp(2)Fe][BPh(4)], in THF results in oxidation of the titanium center, affording the titanium(IV) pentafulvene compound [Cp*(eta(6)-C(5)H(4)=C(10)H(14))Ti(THF)][BPh(4)] (2). Treatmen

  7. Synthesis of Titanium Dioxide Nanocrystals with Controlled Crystal- and Micro-structures from Titanium Complexes

    OpenAIRE

    Makoto Kobayashi; Hideki Kato; Masato Kakihana

    2013-01-01

    Selective synthesis of titanium dioxide (TiO2) polymorphs including anatase, rutile, brookite and TiO2(B) by solvothermal treatment of water-soluble titanium complexes is described with a special focus on their morphological control. The utilization of water-soluble titanium complexes as a raw material allowed us to employ various additives in the synthesis of TiO2. As a result, the selective synthesis of the polymorphs, as well as diverse morphological control, was achieved.

  8. Microstructure of alumina-matrix composites reinforced with nanometric titanium and titanium carbide dispersions

    OpenAIRE

    Elizabeth Refugio-García; David Hernández-Silva; Eduardo Terrés-Rojas; José Amparo Rodríguez-García; Enrique Rocha-Rangel

    2012-01-01

    The synthesis of alumina (Al2O3)-composites having different amount of very fine titanium and titanium carbide reinforcement-particles has been explored. Two experimental steps have been set for the synthesis; the first step consisted of the pressureless-sintering of Al2O3-titanium powders which were thoroughly mixed under high energy ball-milling and through the second step it was induced the formation of titanium carbide during different times at 500 ºC by the cementation packing process. S...

  9. Synthesis and controllable wettability of micro- and nanostructured titanium phosphate thin films formed on titanium plates.

    Science.gov (United States)

    Yada, Mitsunori; Inoue, Yuko; Sakamoto, Ayako; Torikai, Toshio; Watari, Takanori

    2014-05-28

    The hydrothermal treatment of a titanium plate in a mixed aqueous solution of hydrogen peroxide and aqueous phosphoric acid under different conditions results in the formation of various titanium phosphate thin films. The films have various crystal structures such as Ti2O3(H2PO4)2·2H2O, α-titanium phosphate (Ti(HPO4)2·H2O), π-titanium phosphate (Ti2O(PO4)2·H2O), or low-crystallinity titanium phosphate and different morphologies that have not been previously reported such as nanobelts, microflowers, nanosheets, nanorods, or nanoplates. The present study also suggests the mechanisms behind the formation of these thin films. The crystal structure and morphology of the titanium phosphate thin films depend strongly on the concentration of the aqueous hydrogen peroxide solution, the amount of phosphoric acid, and the reaction temperature. In particular, hydrogen peroxide plays an important role in the formation of the titanium phosphate thin films. Moreover, controllable wettability of the titanium phosphate thin films, including superhydrophilicity and superhydrophobicity, is reported. Superhydrophobic surfaces with controllable adhesion to water droplets are obtained on π-titanium phosphate nanorod thin films modified with alkylamine molecules. The adhesion force between a water droplet and the thin film depends on the alkyl chain length of the alkylamine and the duration of ultraviolet irradiation utilized for photocatalytic degradation.

  10. [Comparison of the biological tolerance of titanium and titanium alloys in human gingiva cell cultures].

    Science.gov (United States)

    Hehner, B; Heidemann, D

    1989-01-01

    Mirror-finished solid specimens of pure titanium and the titanium alloys Ti-6Al-4V as well as Ti-5Al-2.5Fe showed no effects on the growth behavior and cell morphology of human gingival epithelial cell and fibroblast cultures. The growth of the cells contacting all three materials was uninhibited. SEM revealed growth of fibroblasts on the surfaces of the specimens, too. No differences could be found between the biocompatibility of titanium alloys and that of pure titanium. The formation of a stable surface oxide layer providing resistance to corrosion may be decisive.

  11. Preparation of highly porous NiO–gadolinium-doped ceria nano-composite powders by one-pot glycine nitrate process for anode-supported tubular solid oxide fuel cells

    Directory of Open Access Journals (Sweden)

    Seung-Young Park

    2014-12-01

    Full Text Available Highly porous NiO–gadolinium-doped ceria (GDC nano-composite powders are synthesized by a one-pot glycine nitrate process and applied to the fabrication of Ni–YSZ (yttria-stabilized zirconia-supported tubular solid oxide fuel cells (SOFCs with a cell configuration of Ni–YSZ/Ni/Ni–GDC/GDC/LSCF (La0.6Sr0.4Co0.2Fe0.8O3−δ–GDC/LSCF. The power density of the cell is as high as 413 mW cm−2 at 600 °C, which is 1.37 times higher than that of an identically configured cell fabricated using ball milling-derived NiO–GDC powders (301 mW cm−2. The high porosity of the powders and the good mixing between the NiO and GDC primary nanoparticles due to the abrupt combustion of the precursors effectively suppress the densification, coarsening, and agglomeration of NiO and GDC particles during sintering, resulting in a highly porous Ni–GDC anode layer with good dispersion of Ni and GDC particles and a cell with significantly enhanced power density.

  12. Titanium Heat Pipe Thermal Plane Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Thermacore Inc. proposes an innovative titanium heat pipe thermal plane for passive thermal control of individual cells within a fuel cell stack. The proposed...

  13. Titanium Heat Pipe Thermal Plane Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of the Phase II program is to complete the development of the titanium heat pipe thermal plane and establish all necessary steps for production of this...

  14. Titanium nitride nanoparticles for therapeutic applications

    DEFF Research Database (Denmark)

    Guler, Urcan; Kildishev, Alexander V.; Boltasseva, Alexandra;

    2014-01-01

    Titanium nitride nanoparticles exhibit plasmonic resonances in the biological transparency window where high absorption efficiencies can be obtained with small dimensions. Both lithographic and colloidal samples are examined from the perspective of nanoparticle thermal therapy. © 2014 OSA....

  15. Advanced Surface Engineering of Titanium Alloys

    Institute of Scientific and Technical Information of China (English)

    H. Dong

    2000-01-01

    Despite their outstanding combination of properties, titanium and its alloys are very susceptible to severe adhesive wear in rubbing with most engineering surfaces and can exhibit poorcorrosion resistance in some aggressive environments. Surface engineering research centred at the University of Birmingham has been focused on creating designer surfaces for titanium components via surface engineering.Great progress has been made recently through the development of such advanced surface engineering techniques as thermal oxidation, palladium-treated thermal oxidation, oxygen boost diffusion and duplex systems.Such advances thus provide scope for designing titanium components for a diversified range of engineering application, usually as direct replacements for steel components. By way of example, some of the successful steps towards titanium designer surfaces are demonstrated. To data, the potential of these advanced technologies has been realised first in auto-sport and off-shore industrials.

  16. Solid metal induced embrittlement of titanium alloys

    OpenAIRE

    Åkerfeldt, Pia

    2012-01-01

    Titanium alloys were for a time believed to be highly resistant to environmentally assisted cracking because of their ability to form a protective oxide film on the surface. Their resistance can still be considered to be high, but when cracking resistance was originally defined to ensure reliable functionality of fracture-critical components, certain conditions that promote cracking were discovered. One of the environmental assisted cracking processes relevant to titanium alloys is solid meta...

  17. Interfacial reactions between titanium and borate glass

    Energy Technology Data Exchange (ETDEWEB)

    Brow, R.K. [Sandia National Labs., Albuquerque, NM (United States); Saha, S.K.; Goldstein, J.I. [Lehigh Univ., Bethlehem, PA (United States). Dept. of Materials Science

    1992-12-31

    Interfacial reactions between melts of several borate glasses and titanium have been investigated by analytical scanning electron microscopy (SEM) and x-ray photoelectron spectroscopy (XPS). A thin titanium boride interfacial layer is detected by XPS after short (30 minutes) thermal treatments. ASEM analyses after longer thermal treatments (8--120 hours) reveal boron-rich interfacial layers and boride precipitates in the Ti side of the interface.

  18. Initial cytotoxicity of novel titanium alloys.

    Science.gov (United States)

    Koike, M; Lockwood, P E; Wataha, J C; Okabe, T

    2007-11-01

    We assessed the biological response to several novel titanium alloys that have promising physical properties for biomedical applications. Four commercial titanium alloys [Super-TIX(R) 800, Super-TIX(R) 51AF, TIMETAL(R) 21SRx, and Ti-6Al-4V (ASTM grade 5)] and three experimental titanium alloys [Ti-13Cr-3Cu, Ti-1.5Si and Ti-1.5Si-5Cu] were tested. Specimens (n = 6; 5.0 x 5.0 x 3.0 mm(3)) were cast in a centrifugal casting machine using a MgO-based investment and polished to 600 grit, removing 250 mum from each surface. Commercially pure titanium (CP Ti: ASTM grade 2) and Teflon (polytetrafluoroethylene) were used as positive controls. The specimens were cleaned and disinfected, and then each cleaned specimen was placed in direct contact with Balb/c 3T3 fibroblasts for 72 h. The cytotoxicity [succinic dehydrogenase (SDH) activity] of the extracts was assessed using the MTT method. Cytotoxicity of the metals tested was not statistically different compared to the CP Ti and Teflon controls (p > 0.05). These novel titanium alloys pose cytotoxic risks no greater than many other commonly used alloys, including commercially pure titanium. The promising short-term biocompatibility of these Ti alloys is probably due to their excellent corrosion resistance under static conditions, even in biological environments.

  19. TEFLON VS TITANIUM PROSTHESES IN STAPES SURGERY

    Directory of Open Access Journals (Sweden)

    Rajesh Vishwakarma

    2014-04-01

    Full Text Available BACKGROUND: Otosclerosis is one of the most leading causes of conductive hearing loss with intact tympanic membrane in adults. Stapes prostheses have seen many changes in its shape, design and material. Both Teflon and Titanium prostheses used in this study having different method of application are reviewed in detail. OBJECTIVE: To compare the outcomes of use of Teflon and Titanium prostheses in stapedotomy surgery in patients with conductive hearing loss. STUDY DESIGN: Prospective study SETTING: Tertiary referral centre METHODS: A prospective study of 50 patients of otosclerosis, who underwent stapedotomy at B.J.Medical College, Civil Hospital, Ahmedabad, with Teflon/Titanium prostheses, from June 2009-February 2012 was done. Follow up was done for a minimum period of 6 months. Revision cases were excluded. A comparison of prostheses was concluded by differences in AB (Air Bone Gap. RESULT: Postoperative ABG of 20db or less was seen in 96% in both groups. The mean postoperative ABGap was 8.2 dB and 11.5 dB for Teflon and Titanium group respectively. There was no statistically significance difference noted in ABGap between Teflon and Titanium pistons at 95% confidence limit at P<0.05. There was significant improvement of AC thresholds at each frequency except for above 4 kHz, in postoperative period. CONCLUSION: Both prostheses provide equal benefit to patients and there is no statistically significant difference between the uses of Teflon/Titanium prostheses. Long term results are still to be analyzed.

  20. Microstructure of alumina-matrix composites reinforced with nanometric titanium and titanium carbide dispersions

    Directory of Open Access Journals (Sweden)

    Elizabeth Refugio-García

    2012-12-01

    Full Text Available The synthesis of alumina (Al2O3-composites having different amount of very fine titanium and titanium carbide reinforcement-particles has been explored. Two experimental steps have been set for the synthesis; the first step consisted of the pressureless-sintering of Al2O3-titanium powders which were thoroughly mixed under high energy ball-milling and through the second step it was induced the formation of titanium carbide during different times at 500 ºC by the cementation packing process. SEM and EDS analysis of the microstructures obtained in both sintered and cemented bodies were performed in order to know the effect of the activated carbon used as cementing agent on the titanium for each studied composite. It was observed that a titanium carbide layer growth from the surface into the bulk and reaches different depth as the titanium content in the composites increases. On the other hand, the use of ductile titanium notably enhanced density level and fracture toughness of the composites.

  1. Patterning of periodic high-aspect-ratio nanopores in anatase titanium dioxide from titanium fluoride hydrolysis.

    Science.gov (United States)

    Tevis, Ian D; Stupp, Samuel I

    2011-05-01

    We report straight pores in titanium dioxide produced by a pattern transfer method with titanium fluoride hydrolysis. The resulting films on fluorine-doped tin oxide had pores with diameters of 30 nm and depths of 500 nm, corresponding to aspect ratios of 1:17.

  2. Oxidation resistant coating for titanium alloys and titanium alloy matrix composites

    Science.gov (United States)

    Brindley, William J. (Inventor); Smialek, James L. (Inventor); Rouge, Carl J. (Inventor)

    1992-01-01

    An oxidation resistant coating for titanium alloys and titanium alloy matrix composites comprises an MCrAlX material. M is a metal selected from nickel, cobalt, and iron. X is an active element selected from Y, Yb, Zr, and Hf.

  3. Creating nanoshell on the surface of titanium hydride bead

    Directory of Open Access Journals (Sweden)

    PAVLENKO Vyacheslav Ivanovich

    2016-12-01

    Full Text Available The article presents data on the modification of titanium hydride bead by creating titanium nanoshell on its surface by ion-plasma vacuum magnetron sputtering. To apply titanium nanoshell on the titanium hydride bead vacuum coating plant of multifunctional nanocomposite coatings QVADRA 500 located in the center of high technology was used. Analysis of the micrographs of the original surface of titanium hydride bead showed that the microstructure of the surface is flat, smooth, in addition the analysis of the microstructure of material surface showed the presence of small porosity, roughness, mainly cavities, as well as shallow longitudinal cracks. The presence of oxide film in titanium hydride prevents the free release of hydrogen and fills some micro-cracks on the surface. Differential thermal analysis of both samples was conducted to determine the thermal stability of the initial titanium hydride bead and bead with applied titanium nanoshell. Hydrogen thermal desorption spectra of the samples of the initial titanium hydride bead and bead with applied titanium nanoshell show different thermal stability of compared materials in the temperature range from 550 to 860о C. Titanium nanoshells applied in this way allows increasing the heat resistance of titanium hydride bead – the temperature of starting decomposition is 695о C and temperature when decomposition finishes is more than 1000о C. Modified in this way titanium hydride bead can be used as a filler in the radiation protective materials used in the construction or upgrading biological protection of nuclear power plants.

  4. Effect of Alkali-Acid-Heat Chemical Surface Treatment on Electron Beam Melted Porous Titanium and Its Apatite Forming Ability

    Directory of Open Access Journals (Sweden)

    Suzan Bsat

    2015-04-01

    Full Text Available Advanced additive manufacturing techniques such as electron beam melting (EBM, can produce highly porous structures that resemble the mechanical properties and structure of native bone. However, for orthopaedic applications, such as joint prostheses or bone substitution, the surface must also be bio-functionalized to promote bone growth. In the current work, EBM porous Ti6Al4V alloy was exposed to an alkali acid heat (AlAcH treatment to bio-functionalize the surface of the porous structure. Various molar concentrations (3, 5, 10M and immersion times (6, 24 h of the alkali treatment were used to determine optimal parameters. The apatite forming ability of the samples was evaluated using simulated body fluid (SBF immersion testing. The micro-topography and surface chemistry of AlAcH treated samples were evaluated before and after SBF testing using scanning electron microscopy and energy dispersive X-ray spectroscopy. The AlAcH treatment successfully modified the topographical and chemical characteristics of EBM porous titanium surface creating nano-topographical features ranging from 200–300 nm in size with a titania layer ideal for apatite formation. After 1 and 3 week immersion in SBF, there was no Ca or P present on the surface of as manufactured porous titanium while both elements were present on all AlAcH treated samples except those exposed to 3M, 6 h alkali treatment. An increase in molar concentration and/or immersion time of alkali treatment resulted in an increase in the number of nano-topographical features per unit area as well as the amount of titania on the surface.

  5. Amorphous titanium-oxide supercapacitors

    Science.gov (United States)

    Fukuhara, Mikio; Kuroda, Tomoyuki; Hasegawa, Fumihiko

    2016-10-01

    The electric capacitance of an amorphous TiO2-x surface increases proportionally to the negative sixth power of the convex diameter d. This occurs because of the van der Waals attraction on the amorphous surface of up to 7 mF/cm2, accompanied by extreme enhanced electron trapping resulting from both the quantum-size effect and an offset effect from positive charges at oxygen-vacancy sites. Here we show that a supercapacitor, constructed with a distributed constant-equipment circuit of large resistance and small capacitance on the amorphous TiO2-x surface, illuminated a red LED for 37 ms after it was charged with 1 mA at 10 V. The fabricated device showed no dielectric breakdown up to 1,100 V. Based on this approach, further advances in the development of amorphous titanium-dioxide supercapacitors might be attained by integrating oxide ribbons with a micro-electro mechanical system.

  6. Advances of Titanium Alloys and Its Biological Surface Modification

    Institute of Scientific and Technical Information of China (English)

    XU Ke-wei; HUANG Ping

    2004-01-01

    This paper reviews the past, present and future of surface modification of titanium alloy from the point of view of preparation of hard tissue replacement implants. The development of titanium alloy is also described.

  7. Colloidal Plasmonic Titanium Nitride Nanoparticles: Properties and Applications

    DEFF Research Database (Denmark)

    Guler, Urcan; Suslov, Sergey; Kildishev, Alexander V.;

    2015-01-01

    Optical properties of colloidal plasmonic titanium nitride nanoparticles are examined with an eye on their photothermal and photocatalytic applications via transmission electron microscopy and optical transmittance measurements. Single crystal titanium nitride cubic nanoparticles with an average...

  8. Thermodynamics Behavior of Titanium for BOF Smelting Bearing Steel

    Institute of Scientific and Technical Information of China (English)

    LIU Yue; WU Wei; LIU Liu; LIU Ming; LI Yang-zhou

    2006-01-01

    When titanium element appears in bearing steel, it is very easy to create titanium nitride inclusion, which reduces the fatigue life of bearing steel. Based on the production data of bearing steel produced by BOF, it is found that the titanium takes its source in bearing steel; the factors affecting titanium content, and the thermodynamics behavior of titanium under smelting condition were studied. The results show that the prime reasons of titanium content increment are the soluble aluminum content and the titanium oxide of slag. The comparison between the experimental data and theoretical ones shows that there is a big declination when the soluble aluminum content of steel is higher, which is caused by the nonequilibrium reaction of slag and steel. The apparent equilibrium distribution coefficient of titanium between slag and steel is obtained by use of experimental data.

  9. Engineering titanium surfaces for improving osteointegration

    Science.gov (United States)

    Lu, Xiong

    Titanium is one of the most important metallic biomedical materials in clinical applications. One of the key issues for successful application of titanium is the interaction at the interface between the titanium and the bone. The present study focuses on improving the surfaces of titanium to achieve better capability to bond with natural bone (i.e. better osteointegration). The objectives of this work include: (1) Developing microfabrication methods to produce micropatterns on titanium surfaces for promoting osteointegration; (2) Studying the calcium phosphate (Ca-P) formation on the chemical treated titanium surface and elucidating the mechanism of precipitation theoretically; and (3) Evaluating osteoconductivity of engineering titanium surfaces in vitro and in vivo. Through mask electrochemical micromachining (TMEMM), jet electrochemical micromachining (Jet-EMM) and the confined etchant layer technique (CELT) were attempted to produce micropatterns on titanium surfaces. TMEMM has a high etching rate and good reproducibility and was used to produce micro-hole arrays on Ti plates for in vivo testing. The driving force and nucleation rate of Ca-P precipitation in simulated body fluid (SBF) were analyzed based on the classical crystallization theory. SBF supersaturation with respect to HA, OCP and DCPD (dicalcium phosphate) was carefully calculated, considering all the association/dissociation reactions of related ion groups in SBF. The analysis indicates that the nucleation rate of OCP is substantially higher than that of HA, while HA is most thermodynamically stable in SBF. DCPD precipitation is thermodynamically impossible in normal SBF, unless calcium and phosphate ion concentrations of SBF increase. Osteoconduction of Ti6Al4V surfaces under various conditions, including micro-patterned, alkali-treated, micro-patterned plus alkali-treated, and surfaces without any treatment, was evaluated. TMEMM was used to fabricate micro-hole arrays on the titanium alloy

  10. Laser induced single spot oxidation of titanium

    Science.gov (United States)

    Jwad, Tahseen; Deng, Sunan; Butt, Haider; Dimov, S.

    2016-11-01

    Titanium oxides have a wide range of applications in industry, and they can be formed on pure titanium using different methods. Laser-induced oxidation is one of the most reliable methods due to its controllability and selectivity. Colour marking is one of the main applications of the oxidation process. However, the colourizing process based on laser scanning strategies is limited by the relative large processing area in comparison to the beam size. Single spot oxidation of titanium substrates is proposed in this research in order to increase the resolution of the processed area and also to address the requirements of potential new applications. The method is applied to produce oxide films with different thicknesses and hence colours on titanium substrates. High resolution colour image is imprinted on a sheet of pure titanium by converting its pixels' colours into laser parameter settings. Optical and morphological periodic surface structures are also produced by an array of oxide spots and then analysed. Two colours have been coded into one field and the dependencies of the reflected colours on incident and azimuthal angles of the light are discussed. The findings are of interest to a range of application areas, as they can be used to imprint optical devices such as diffusers and Fresnel lenses on metallic surfaces as well as for colour marking.

  11. Formation of nanoscale titanium carbides in ferrite: an atomic study

    Science.gov (United States)

    Lv, Yanan; Hodgson, Peter; Kong, Lingxue; Gao, Weimin

    2016-03-01

    The formation and evolution of nanoscale titanium carbide in ferrite during the early isothermal annealing process were investigated via molecular dynamics simulation. The atomic interactions of titanium and carbon atoms during the initial formation process explained the atoms aggregation and carbides formation. It was found that the aggregation and dissociation of titanium carbide occurred simultaneously, and the composition of carbide clusters varied in a wide range. A mechanism for the formation of titanium carbide clusters in ferrite was disclosed.

  12. The Progress on Laser Surface Modification Techniques of Titanium Alloy

    Institute of Scientific and Technical Information of China (English)

    LIANG Cheng; PAN Lin; Al Ding-fei; TAO Xi-qi; XIA Chun-huai; SONG Yan

    2004-01-01

    Titanium alloy is widely used in aviation, national defence, automobile, medicine and other fields because of their advantages in lower density, corrosion resistance, and fatigue resistance etc. As titanium alloy is higher friction coefficients, weak wear resistance, bad high temperature oxidation resistance and lower biocompatibility, its applications are restricted. Using laser surface modification techniques can significantly improve the surface properties of titanium alloy. a review is given for progress on laser surface modification techniques of titanium alloy in this paper.

  13. Plasma Induced Grafting of PMMA onto Titanium Dioxide Powder

    Institute of Scientific and Technical Information of China (English)

    Zhong Shaofeng; Meng Yuedong; Ou Qiongrong; Xu Xu

    2005-01-01

    Grafting of polymer of methyl methacrylate (PMMA) onto titanium dioxide powder is investigated in this paper. The graft polymerization reaction is induced by dielectric-barrierdischarge produced N2 plasma treatment of titanium dioxide surfaces. IR, XPS and TGA results show that PMMA is grafted onto the surfaces of titanium dioxide powder. And crystal structure of the titanium dioxide powder observed with XRD spectra is unchanged after plasma graft polymerization.

  14. Solvolysis of titanium tetrachloride in non-aqueous media as a method for producing titanium dioxide particles of different morphology

    OpenAIRE

    A. M Nemeryuk; M. M Lylina

    2015-01-01

    The processes of solvolysis of titanium tetrachloride in nonaqueous media were studied. The influence of the conditions of solvolysis on the size and morphology of the particles of titanium dioxide produced have been described.

  15. Individual prefabricated titanium implants and titanium mesh in skull base reconstructive surgery. A report of cases.

    Science.gov (United States)

    Schipper, J; Ridder, G J; Spetzger, U; Teszler, C B; Fradis, M; Maier, W

    2004-05-01

    Titanium implants can be shaped by traditional hand forming, press shaping, modular construction by welding, construction on full-size models shaped from CT coordinates and, most recently, by computer-assisted design and computer-assisted manufacturing (CAD/CAM) that consist in the direct prefabrication of individual implants by milling them out of a solid block of titanium. The aim of our study was to present a set of preliminary cases of an ongoing program of reconstructive procedures of the skull base using titanium implants. The subjects underwent ablative procedures of the skull base with reconstruction either by titanium mesh or individual prefabricated CAD/CAM implants. Six patients have been operated on successfully since 2000: two received prefabricated CAD/CAM titanium plates and four others underwent reconstruction with titanium mesh. The stability of CAD/CAM plates is superior to that of mesh, thus it is more useful in reconstructing large lesions of the frontal skull base and the temporal and occipital bones. Titanium mesh was successfully used for defects smaller than 100 cm(2) or where selected viscerocranial defects are complicated in design and less reproducible by CAD/CAM. The intraoperative design, shaping and adjustment characteristic of titanium mesh can be dispensed with when CAD/CAM implants are used. The 3-D data set used in the CAD/CAM process also operates in the navigated simulation and planning of the ablation contours, the latter being of great assistance in establishing the optimal future defect. As a disadvantage, CAD/CAM technology is more expensive than titanium mesh, and the process is time-consuming as it is carried out in advance of surgery.

  16. Enhancing osseointegration using surface-modified titanium implants

    Science.gov (United States)

    Yang, Y.; Oh, N.; Liu, Y.; Chen, W.; Oh, S.; Appleford, M.; Kim, S.; Kim, K.; Park, S.; Bumgardner, J.; Haggard, W.; Ong, J.

    2006-07-01

    Osseointegrated dental implants are used to replace missing teeth. The success of implants is due to osseointegration or the direct contact of the implant surface and bone without a fibrous connective tissue interface. This review discusses the enhancement of osseointegration by means of anodized microporous titanium surfaces, functionally macroporous graded titanium coatings, nanoscale titanium surfaces, and different bioactive factors.

  17. Array of titanium dioxide nanostructures for solar energy utilization

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, Xiaofeng; Parans Paranthaman, Mariappan; Chi, Miaofang; Ivanov, Ilia N; Zhang, Zhenyu

    2014-12-30

    An array of titanium dioxide nanostructures for solar energy utilization includes a plurality of nanotubes, each nanotube including an outer layer coaxial with an inner layer, where the inner layer comprises p-type titanium dioxide and the outer layer comprises n-type titanium dioxide. An interface between the inner layer and the outer layer defines a p-n junction.

  18. Corrosion behavior of titanium wires: An in vitro study

    Directory of Open Access Journals (Sweden)

    Thakur Prasad Chaturvedi

    2012-01-01

    Results: The results showed degradation of titanium wires by electrochemical attack when they were placed in the hostile electrolytic environments provided in the experiments. Surface analysis of titanium wires showed pitting and localized attacks on the surface. Pitting corrosion was found in the titanium wires.

  19. Asymmetric Catalytic Reactions Catalyzed by Chiral Titanium Complexes

    Institute of Scientific and Technical Information of China (English)

    FENG XiaoMing

    2001-01-01

    @@ Chiral titanium complexes is very importance catalyst to asymmetric catalytic reactions. A series of catalytic systems based on titanium-chiral ligands complexes has been reported. This presentation will discuss some of our recent progress on asymmetric catalytic reactions catalyzed by chiral titanium complexes.

  20. Asymmetric Catalytic Reactions Catalyzed by Chiral Titanium Complexes

    Institute of Scientific and Technical Information of China (English)

    FENG; XiaoMing

    2001-01-01

    Chiral titanium complexes is very importance catalyst to asymmetric catalytic reactions. A series of catalytic systems based on titanium-chiral ligands complexes has been reported. This presentation will discuss some of our recent progress on asymmetric catalytic reactions catalyzed by chiral titanium complexes.  ……

  1. China Customs Removed the Import Tax on Titanium Slag

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    <正>The long waited solution to the problem relating to the import of titanium slag has finally resolved. According to China Customs report, the import of titanium slag no longer requires tax payment as from January 1, 2007. This decision will help with the healthy development of China’s titanium industry and increase China’s competitiveness in the international marketplace.

  2. Applications of Titanium Dioxide Photocatalysis to Construction Materials

    CERN Document Server

    Ohama, Yoshihiko

    2011-01-01

    Titanium dioxide photocatalysis is based on the semiconducting nature of its anatase crystal type. Construction materials with titanium photocatalyst show performances of air purification, self-cleaning, water purification, antibacterial action. This book describes principles of titanium dioxide photocatalysis, its applications to cementitious and noncementitious materials, as well as an overview of standardization of testing methods.

  3. Development and application of titanium alloy casting technology in China

    Institute of Scientific and Technical Information of China (English)

    NAN Hai; XIE Cheng-mu; ZHAO Jia-qi

    2005-01-01

    The development and research of titanium cast alloy and its casting technology, especially its application inaeronautical industry in China are presented. The technology of molding, melting and casting of titanium alloy, casting quality control are introduced. The existing problems and development trend in titanium alloy casting technology are also discussed.

  4. Titanium carbide nanocrystals in circumstellar environments.

    Science.gov (United States)

    von Helden, G; Tielens, A G; van Heijnsbergen, D; Duncan, M A; Hony, S; Waters, L B; Meijer, G

    2000-04-14

    Meteorites contain micrometer-sized graphite grains with embedded titanium carbide grains. Although isotopic analysis identifies asymptotic giant branch stars as the birth sites of these grains, there is no direct observational identification of these grains in astronomical sources. We report that infrared wavelength spectra of gas-phase titanium carbide nanocrystals derived in the laboratory show a prominent feature at a wavelength of 20.1 micrometers, which compares well to a similar feature in observed spectra of postasymptotic giant branch stars. It is concluded that titanium carbide forms during a short (approximately 100 years) phase of catastrophic mass loss (>0.001 solar masses per year) in dying, low-mass stars.

  5. Titanium in fatigue critical military aircraft structure

    Energy Technology Data Exchange (ETDEWEB)

    Gillespie, F.

    1999-07-01

    This paper discusses the effect of fatigue requirements on titanium structure in military aircraft applications, specifically, fighter aircraft. The discussion covers how fatigue affects the design and analysis of detail parts, and how manufacturing processes affect the fatigue performance of titanium structure. Criteria for designing fighter aircraft have evolved from simple strength calculations to extremely complex computer generated analyses involving strength, durability, damage tolerance and fatigue. Fatigue life prediction is an important part of these analyses and dramatically affects the design and weight of fighter aircraft. Manufacturing processes affect fatigue performance both in a positive and negative manner. Designers must allow for the effect of these processes on titanium structure and consider the efficiency and economy of adding processes that increase fatigue life.

  6. Atom probe analysis of titanium hydride precipitates.

    Science.gov (United States)

    Takahashi, J; Kawakami, K; Otsuka, H; Fujii, H

    2009-04-01

    It is expected that the three-dimensional atom probe (3DAP) will be used as a tool to visualize the atomic scale of hydrogen atoms in steel is expected, due to its high spatial resolution and very low detection limit. In this paper, the first 3DAP analysis of titanium hydride precipitates in metal titanium is reported in terms of the quantitative detection of hydrogen. FIB fabrication techniques using the lift-out method have enabled the production of needle tips of hydride precipitates, of several tens of microns in size, within a titanium matrix. The hydrogen concentration estimated from 3DAP analysis was slightly smaller than that of the hydride phase predicted from the phase diagram. We discuss the origin of the difference between the experimental and predicted values and the performance of 3DAP for the quantitative detection of hydrogen.

  7. Potentiodynamic behaviour of mechanically polished titanium electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Camara, O.R.; DePauli, C.P.; Giordano, M.C.

    1984-08-01

    The behaviour of titanium electrodes mechanically polished and/or anodically polarized at low positive potential in solutions at constant ionic strength between pH 0.3 and 11.0 is reported. The oxide electroformation potential on a mechanically polished electrode shows a complex dependence on the bulk solution pH. This dependence is similar to that obtained through acid-base titration with titanium as the indicating electrode. The formation of hydroxo-complexes on the spontaneously formed titanium oxide offers a possible explanation for the oxide electroformation potential dependence on pH. Anodic and cathodic wide current peaks are obtained between the potential of the hydrogen evolution and that of the massive oxide electroformation; the corresponding redox system becomes evident at pH 4.0 from the first potentiodynamic cycle. An interpretation of these processes involving the participation of non stoichiometric oxides and hydrogen ions is attempted.

  8. Stainless Steel to Titanium Bimetallic Transitions

    Energy Technology Data Exchange (ETDEWEB)

    Kaluzny, J. A. [Fermilab; Grimm, C. [Fermilab; Passarelli, D. [Fermilab

    2015-01-01

    In order to use stainless steel piping in an LCLS-II (Linac Coherent Light Source Upgrade) cryomodule, stainless steel to titanium bimetallic transitions are needed to connect the stainless steel piping to the titanium cavity helium vessel. Explosion bonded stainless steel to titanium transition pieces and bimetallic transition material samples have been tested. A sample transition tube was subjected to tests and x-ray examinations between tests. Samples of the bonded joint material were impact and tensile tested at room temperature as well as liquid helium temperature. The joint has been used successfully in horizontal tests of LCLS-II cavity helium vessels and is planned to be used in LCLS-II cryomodules. Results of material sample and transition tube tests will be presented.

  9. Genotoxicity of titanium dioxide nanoparticles

    Directory of Open Access Journals (Sweden)

    Tao Chen

    2014-03-01

    Full Text Available Titanium dioxide nanoparticles (TiO2-NPs, <100 nm are increasingly being used in pharmaceuticals and cosmetics due to the unique properties derived from their small sizes. However, their large surface-area to mass ratio and high redox potential may negatively impact human health and the environment. TiO2-NPs can cause inflammation, pulmonary damage, fibrosis, and lung tumors and they are possibly carcinogenic to humans. Because cancer is a disease involving mutation, there are a large number of studies on the genotoxicity of TiO2-NPs. In this article, we review the results that have been reported in the literature, with a focus on data generated from the standard genotoxicity assays. The data include genotoxicity results from the Ames test, in vitro and in vivo Comet assay, in vitro and in vivo micronucleus assay, sister chromatid exchange assay, mammalian cell hypoxanthine-guanine phosphoribosyl transferase gene assay, the wing somatic mutation and recombination assay, and the mouse phosphatidylinositol glycan, class A gene assay. Inconsistent results have been found in these assays, with both positive and negative responses being reported. The in vitro systems for assessing the genotoxicity of TiO2-NPs have generated a greater number of positive results than the in vivo systems, and tests for DNA and chromosome damage have produced more positive results than the assays measuring gene mutation. Nearly all tests for measuring the mutagenicity of TiO2-NPs were negative. The current data indicate that the genotoxicity of TiO2-NPs is mediated mainly through the generation of oxidative stress in cells.

  10. Method for the production of strongly adhesive films on titanium and titanium alloys with a metallization process

    Science.gov (United States)

    Hahn, H. J.

    1986-01-01

    A process for the spray-application of a strongly adhesive, thick antifriction layer on titanium and titanium alloys is proposed. The titanium/titanium alloy component to be coated is first subjected to cleaning in a pickling bath with reducing additives and sand-blasting, then coated with an intermediate layer of nickel, after which the final layer is applied. The formation of TiNi at the interface ensures strong bonding of the antifriction layer.

  11. Hydrogen storage with titanium-functionalized graphene

    CERN Document Server

    Mashoff, Torge; Tanabe, Shinichi; Hibino, Hiroki; Beltram, Fabio; Heun, Stefan

    2013-01-01

    We report on hydrogen adsorption and desorption on titanium-covered graphene in order to test theoretical proposals to use of graphene functionalized with metal atoms for hydrogen storage. At room temperature titanium islands grow with an average diameter of about 10 nm. Samples were then loaded with hydrogen, and its desorption kinetics was studied by thermal desorption spectroscopy. We observe the desorption of hydrogen in the temperature range between 400K and 700 K. Our results demonstrate the stability of hydrogen binding at room temperature and show that hydrogen desorbs at moderate temperatures in line with what required for practical hydrogen-storage applications.

  12. Local heating with titanium nitride nanoparticles

    DEFF Research Database (Denmark)

    Guler, Urcan; Ndukaife, Justus C.; Naik, Gururaj V.;

    2013-01-01

    We investigate the feasibility of titanium nitride (TiN) nanoparticles as local heat sources in the near infrared region, focusing on biological window. Experiments and simulations provide promising results for TiN, which is known to be bio-compatible.......We investigate the feasibility of titanium nitride (TiN) nanoparticles as local heat sources in the near infrared region, focusing on biological window. Experiments and simulations provide promising results for TiN, which is known to be bio-compatible....

  13. Powder injection molding of pure titanium

    Institute of Scientific and Technical Information of China (English)

    GUO Shibo; DUAN Bohua; HE Xinbo; QU Xuanhui

    2009-01-01

    An improved wax-based binder was developed for powder injection molding of pure titanium. A critical powder loading of 69 vol.% and a pseudo-plastic flow behavior were obtained by the feedstock based on the binder. The injection molding, debinding, and sintering process were studied. An ideal control of carbon and oxygen contents was achieved by thermal debinding in vacuum atmosphere (10-3 Pa). The mechanical properties of as-sintered specimens were less than those of titanium made by the conventional press-sintering process. Good shape retention and ±0.04 mm dimension deviation were achieved.

  14. Creating mobile apps with Appcelerator Titanium

    CERN Document Server

    Brousseau, Christian

    2013-01-01

    Creating Mobile Apps with Appcelerator Titanium provides a hands-on approach and working examples on creating apps and games as well as embedding them onto a social networking website. Developers can then move on from there to develop their own applications based on the ones they have developed throughout the course of this book.""Creating Mobile Apps with Appcelerator Titanium"" is for developers who have experience with modern languages and development environments. Also, if you are familiar with the concepts of Object-oriented Programming (OOP), reusable components, AJAX closures, and so on

  15. Rapidly solidified titanium alloys by melt overflow

    Science.gov (United States)

    Gaspar, Thomas A.; Bruce, Thomas J., Jr.; Hackman, Lloyd E.; Brasmer, Susan E.; Dantzig, Jonathan A.; Baeslack, William A., III

    1989-01-01

    A pilot plant scale furnace was designed and constructed for casting titanium alloy strips. The furnace combines plasma arc skull melting techniques with melt overflow rapid solidification technology. A mathematical model of the melting and casting process was developed. The furnace cast strip of a suitable length and width for use with honeycomb structures. Titanium alloys Ti-6Al-4V and Ti-14Al-21 Nb were successfully cast into strips. The strips were evaluated by optical metallography, microhardness measurements, chemical analysis, and cold rolling.

  16. Hybrid Calcium Phosphate Coatings for Titanium Implants

    Science.gov (United States)

    Kharapudchenko, E.; Ignatov, V.; Ivanov, V.; Tverdokhlebov, S.

    2017-01-01

    Hybrid multilayer coatings were obtained on titanium substrates by the combination of two methods: the micro-arc oxidation in phosphoric acid solution with the addition of calcium compounds to high supersaturated state and RF magnetron sputtering of the target made of synthetic hydroxyapatite. 16 different groups of coatings were formed on titanium substrates and in vitro studies were conducted in accordance with ISO 23317 in the solution simulating body fluid. The studies using SEM, XRD of the coatings of the samples before and after exposure to SBF were performed. The features of morphology, chemical and phase composition of the studied coatings are shown.

  17. Direct dynamic synthesis of nanodispersed phases of titanium oxides upon sputtering of electrodischarge titanium plasma into an air atmosphere

    Science.gov (United States)

    Sivkov, A. A.; Gerasimov, D. Yu.; Nikitin, D. S.

    2017-01-01

    Experimental investigations of the possibility of directly synthesizing nanodispersed crystalline phases of titanium dioxides with rutile and anatase structures in a hypervelocity jet of electroerosion plasma generated by a coaxial magnetoplasma accelerator with titanium electrodes are presented. A powder product containing nanosized polymorphic phases of titanium dioxide with a spherical shape of particles has been manufactured.

  18. Structure and properties of Titanium for dental implants

    Directory of Open Access Journals (Sweden)

    M. Greger

    2009-10-01

    Full Text Available This paper describes manufacture of nano-structural titanium, its structure and properties. Nano-titanium has higher specific strength properties than ordinary (coarse-grained titanium. Nano-titanium was produced by the equal-channel angular pressing (ETAP process. The research it self was focused on physical base of strengthening and softening processes and developments occurring at the grain boundaries during the ECAP process at half-hot temperature. Strength of nano-titanium varies around 960 MPa, grain size around 300 nm.

  19. The formation of titanium dioxide crystallite nanoparticles during activation of PAN nanofibers containing titanium isopropoxide

    Energy Technology Data Exchange (ETDEWEB)

    Mehrpouya, Fahimeh; Tavanai, Hossein, E-mail: tavanai@cc.iut.ac.ir; Morshed, Mohammad [Isfahan University of Technology, Department of Textile Engineering, Center of Excellence in Applied Nanotechnology (Iran, Islamic Republic of); Ghiaci, Mehran [Isfahan University of Technology, Department of Chemistry (Iran, Islamic Republic of)

    2012-08-15

    Activated carbon (AC) can act as an important carrier for TiO{sub 2} nanoparticles. TiO{sub 2} nanoparticle can be fabricated by the hydrolysis and condensation of titanium alkoxides like titanium isopropoxide. This study showed that the formation of titanium dioxide crystallite nanoparticle during activation of PAN nanofibers containing titanium isopropoxide leads to the formation of mainly anatase crystal TiO{sub 2} nanoparticle in AC nanofibers, with a good dispersion in both the longitude and cross section of nanofibers. The TiO{sub 2} crystallite size lies in the range of 7.3-11.3 nm. The dispersion of TiO{sub 2} nanoparticles in the matrix of AC nanofibers is far superior to the direct mixing of TiO{sub 2} nanoparticles in the original electrospinning solution.

  20. Titanium Metal Powder Production by the Plasma Quench Process

    Energy Technology Data Exchange (ETDEWEB)

    R. A. Cordes; A. Donaldson

    2000-09-01

    The goals of this project included the scale-up of the titanium hydride production process to a production rate of 50 kg/hr at a purity level of 99+%. This goal was to be achieved by incrementally increasing the production capability of a series of reactor systems. This methodic approach was designed to allow Idaho Titanium Technologies to systematically address the engineering issues associated with plasma system performance, and powder collection system design and performance. With quality powder available, actual fabrication with the titanium hydride was to be pursued. Finally, with a successful titanium production system in place, the production of titanium aluminide was to be pursued by the simultaneously injection of titanium and aluminum precursors into the reactor system. Some significant accomplishments of the project are: A unique and revolutionary torch/reactor capable of withstanding temperatures up to 5000 C with high thermal efficiency has been operated. The dissociation of titanium tetrachloride into titanium powder and HC1 has been demonstrated, and a one-megawatt reactor potentially capable of producing 100 pounds per hour has been built, but not yet operated at the powder level. The removal of residual subchlorides and adsorbed HC1 and the sintering of powder to form solid bodies have been demonstrated. The production system has been operated at production rates up to 40 pounds per hour. Subsequent to the end of the project, Idaho Titanium Technologies demonstrated that titanium hydride powder can indeed be sintered into solid titanium metal at 1500 C without sintering aids.

  1. Titanium Oxide: A Bioactive Factor in Osteoblast Differentiation

    Directory of Open Access Journals (Sweden)

    P. Santiago-Medina

    2015-01-01

    Full Text Available Titanium and titanium alloys are currently accepted as the gold standard in dental applications. Their excellent biocompatibility has been attributed to the inert titanium surface through the formation of a thin native oxide which has been correlated to the excellent corrosion resistance of this material in body fluids. Whether this titanium oxide layer is essential to the outstanding biocompatibility of titanium surfaces in orthopedic biomaterial applications is still a moot point. To study this critical aspect further, human fetal osteoblasts were cultured on thermally oxidized and microarc oxidized (MAO surfaces and cell differentiation, a key indicator in bone tissue growth, was quantified by measuring the expression of alkaline phosphatase (ALP using a commercial assay kit. Cell attachment was similar on all the oxidized surfaces although ALP expression was highest on the oxidized titanium alloy surfaces. Untreated titanium alloy surfaces showed a distinctly lower degree of ALP activity. This indicates that titanium oxide clearly upregulates ALP expression in human fetal osteoblasts and may be a key bioactive factor that causes the excellent biocompatibility of titanium alloys. This result may make it imperative to incorporate titanium oxide in all hard tissue applications involving titanium and other alloys.

  2. Formation and composition of titanium oxinitride nanocrystals synthesized via nitridizing titanium oxide for nonvolatile memory applications

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Li-Wei; Chang, Chun-Yen [Department of Electronics Engineering, National Chiao Tung University, Hsinchu, 300, Taiwan (China); Institute of Electronics, National Chiao Tung University, Hsinchu, 300, Taiwan (China); Chang, Ting-Chang, E-mail: tcchang@mail.phys.nsysu.edu.tw [Department of Physics, National Sun Yat-Sen University, Kaohsiung, 804, Taiwan (China); Center for Nanoscience and Nanotechnology, National Sun Yat-Sen University, Kaohsiung, 804, Taiwan (China); Tu, Chun-Hao; Wang, Pai-Syuan [Department of Electronics Engineering, National Chiao Tung University, Hsinchu, 300, Taiwan (China); Institute of Electronics, National Chiao Tung University, Hsinchu, 300, Taiwan (China); Lin, Chao-Cheng [Green Energy and Environment Research Laboratories, Industrial Technology Research Institute, Hsinchu, 310, Taiwan (China); Chen, Min-Chen [Department of Physics, National Sun Yat-Sen University, Kaohsiung, 804, Taiwan (China); Huang, Hui-Chun; Gan, Der-Shin; Ho, New-Jin [Institute of Materials Science and Engineering, National Sun Yat-Sen University, Kaohsiung, 804, Taiwan (China); Chen, Shih-Ching [Department of Physics, National Sun Yat-Sen University, Kaohsiung, 804, Taiwan (China); Chen, Shih-Cheng [Department of Electrical Engineering, National Tsing Hua University, Hsinchu, 310, Taiwan, ROC (China); Institute of Electronic Engineering, National Tsing Hua University, Hsinchu, 310, Taiwan (China)

    2011-09-01

    Formation and composition analyses of titanium oxinitride nanocrystals (NCs) fabricated via treating a magnetron co-sputtered thin film of titanium and silicon dioxide with a rapid thermal annealing in nitrogen ambient were demonstrated for nonvolatile memory applications. Phase separation characteristics with different annealing conditions were examined by transmission electron microscopy and chemical bonding characteristics were confirmed by X-ray photon emission spectra. It was observed that a blanket layer composed mainly of titanium oxide was still present as annealing temperature was increased to 700 deg. C, associated with the thermodynamically stable phase of titanium oxide. Furthermore, a higher thermal treatment of 900 deg. C induced formation of a well-separated NC structure and caused simultaneously partial nitridation of the titanium oxide, thereby forming titanium oxinitride NCs. A significant capacitance-voltage hysteresis in threshold voltage shift at 1 V was easily achieved under a small sweeping voltage range of + 2 V/-2 V, and a memory window retention of 2.2 V was obtained after 10{sup 7} s by extrapolation under a 1 s initial-program/erase condition of + 5 V/-5 V, respectively.

  3. Study on Crystallization of Titanium Silicalite (Ⅰ)

    Institute of Scientific and Technical Information of China (English)

    Lin Min; Zhu Bin; Shu Xingtian; Wang Xieqing

    2008-01-01

    In order to investigate the rules on preparation of titanium silicalite (TS-1) the 1H→13C CP/MAS NMR spectrometers were applied to track the function of template TPAOH in the process of crystal lization of titanium silicalite.The research results revealed that at the initial stage of crystallization the TPA+ ions acting as the template could predominantly absorb the polymers of negatively charged silicatitania sol and the interactions between silica sol and titania sol could gradually lead to the formation of tiny crystal nuclei that could slowly grow up to form molecular sieves.Upon investigating the course of crystallization of titanium silicalite the 1H→13C CP/MAS NMR spectrometers were applied to effectively enhance the resolution of 29Si signals in the titanium silicalite.Study results have shown that during the formation of tiny crystal nuclei upon interaction between titania sol and silica sol the influence of titania sol on the silica sol was insignificant.However,when tiny crystal nuclei broke out into molecular sieves the titania sol could enter the zeolite framework that could apparently impose an enhanced effect on the silica sol.

  4. Titanium carbide nanocrystals in circumstellar environments

    NARCIS (Netherlands)

    von Helden, G; Tielens, ACGM; van Heijnsbergen, D; Duncan, MA; Hony, S; Waters, LBFM; Meijer, G.

    2000-01-01

    Meteorites contain micrometer-sized graphite grains with embedded titanium carbide grains. Although isotopic analysis identifies asymptotic giant branch stars as the birth sites of these grains, there is no direct observational identification of these grains in astronomical sources. We report that i

  5. Lactobacillus assisted synthesis of titanium nanoparticles

    Science.gov (United States)

    Prasad, K.; Jha, Anal K.; Kulkarni, A. R.

    2007-05-01

    An eco-friendly lactobacillus sp. (microbe) assisted synthesis of titanium nanoparticles is reported. The synthesis is performed at room temperature. X-ray and transmission electron microscopy analyses are performed to ascertain the formation of Ti nanoparticles. Individual nanoparticles as well as a number of aggregates almost spherical in shape having a size of 40 60 nm are found.

  6. Titanium 󈨠: Science and Technology. Volume 3

    Science.gov (United States)

    1993-01-01

    and A. 0. Mah, "Metallurgical Thermochemistry of Titanium’ (Report of Investigations 5490, U.S. Bureau of Mines, 1959), 15. 25. 0. Kubaschewskl and W...for retubing is polished to achieve less cost and shorter shut down time. 2) Thinner gauge tube Long term experience teaches thinner gauge tubes is

  7. Characterization of Micro-arc Oxidized Titanium

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    The observation of the sparkling discharges during the micro-arc oxidation process in KOH aqueous electrolyte was achieved. The change of surface morphology was progressively observed and a plausible pore formation mechanism is proposed. Cell proliferation and ALP activity of micro-arc oxidized titanium was evaluated by human body derived osteoblasts and slightly better than those of blasted surface.

  8. Biocorrosion study of titanium-cobalt alloys.

    Science.gov (United States)

    Chern Lin, J H; Lo, S J; Ju, C P

    1995-05-01

    The present work provides experimental results of corrosion behaviour in Hank's physiological solution and some other properties of in-house fabricated titanium-cobalt alloys with cobalt ranging from 25-30% in weight. X-ray diffraction (XRD) shows that, in water-quenched (WQ) alloys, beta-titanium is largely retained, whereas in furnace-cooled (FC) alloys, little beta-titanium is found. Hardness of the alloys increases with increasing cobalt content, ranging from 455 VHN for WQ Ti-25 wt% Co to 525 VHN for WQ Ti-30 wt% Co. Differential thermal analysis (DTA) indicates that melting temperatures of the alloys are lower than that of pure titanium by about 600 degrees C. Potentiodynamic polarization results show that all measured break-down potentials in Hank's solution at 37 degrees C are higher than 800 mV. The breakdown potential for the FC Ti-25 Wt% Co alloy is even as high as nearly 1200 mV.

  9. Titanium tungsten coatings for bioelectrochemical applications

    DEFF Research Database (Denmark)

    Wierzbicki, Rafal; Amato, Letizia; Łopacińska, J.

    2011-01-01

    This paper presents an assessment of titanium tungsten (TiW) coatings and their applicability as components of biosensing systems. The focus is put on using TiW as an electromechanical interface layer between carbon nanotube (CNT) forests and silicon nanograss (SiNG) cell scaffolds. Cytotoxicity...

  10. Bioactive borate glass coatings for titanium alloys.

    Science.gov (United States)

    Peddi, Laxmikanth; Brow, Richard K; Brown, Roger F

    2008-09-01

    Bioactive borate glass coatings have been developed for titanium and titanium alloys. Glasses from the Na(2)O-CaO-B(2)O(3) system, modified by additions of SiO(2), Al(2)O(3), and P(2)O(5), were characterized and compositions with thermal expansion matches to titanium were identified. Infrared and X-ray diffraction analyses indicate that a hydroxyapatite surface layer forms on the borate glasses after exposure to a simulated body fluid for 2 weeks at 37 degrees C; similar layers form on 45S5 Bioglass((R)) exposed to the same conditions. Assays with MC3T3-E1 pre-osteoblastic cells show the borate glasses exhibit in vitro biocompatibility similar to that of the 45S5 Bioglass((R)). An enameling technique was developed to form adherent borate glass coatings on Ti6Al4V alloy, with adhesive strengths of 36 +/- 2 MPa on polished substrates. The results show these new borate glasses to be promising candidates for forming bioactive coatings on titanium substrates.

  11. 中年患者生物型假体全髋置换178例:7年随访资料回顾分析%Retrospective research on the effect of cementless prosthesis in total hip replacement of 178 middle aged patients during 7-year follow-up

    Institute of Scientific and Technical Information of China (English)

    李强; 唐际存; 王锐英; 贝朝涌; 肖颖; 辛林伟

    2010-01-01

    BACKGROUND: Total hip replacement in middle-aged patients is challenging regarding restoration and survival,because these patients are more active than old patients.OBJECTIVE: To retrospectively investigate whether a cementless prosthesis could restore hip function,decrease osteolysis,wear,and enhance prosthesis survival in middle-aged patients.METHODS: Clinical and radiological evaluations of patients undergoing single-side total hip replacement with cement and cementless prosthesis were analyzed preoperatively as well as at 6 months,1,4 and 7 years postoperatively.The outcomes of total hip replacement were assessed using Harris hip scores and survival rate.End point was loosening or revision of the femoral component for any reason.RESULTS AND CONCLUSION: Cementless prosthesis had gained better Harris hip scores than that of cement prosthesis group at 6 months,1,4 and 7 years postoperatively(P < 0.05).The survival rate was greater in cementless prosthesis compared with cement prosthesis during 7-year follow-up(P < 0.05).Results have suggested that cementless prosthesis achieves high rate of functional restoration and a low rate of complications in middle-aged patients following total hip replacement.%背景:中年患者全髋关节置换后的恢复及假体生存率问题一直以来是一个比较棘手的问题,因为此组患者置换后对关节活动度的要求较老年患者的更高.目的:回顾性分析生物型假体在中年患者全髋关节置换后是否能促进功能恢复,减少骨质疏松及磨损,延长假体寿命.方法;选择以骨水泥型和非骨水泥型假体行单侧伞髋关节置换的中年患者,对该组患者分别于置换前、置换后6个月,1年,4年及7年的临床症状及影像学检查进行随访.以Harris髋关节评分及生存率评价伞髋关节置换效果,以任何原因形成的松动或翻修时间为截尾时间.结果与结论:非骨水泥型假体置换后6个月,1年,4年及7年的Harris评分明

  12. Titanium corrosion in alkaline hydrogen peroxide environments

    Science.gov (United States)

    Been, Jantje

    1998-12-01

    The corrosion of Grade 2 titanium in alkaline hydrogen peroxide environments has been studied by weight loss corrosion tests, electrochemical impedance spectroscopy (EIS), linear polarization resistance (LPR) measurements and potentiodynamic polarography. Calcium ions and wood pulp were investigated as corrosion inhibitors. In alkaline peroxide, the titanium corrosion rate increased with increasing pH, temperature, and hydrogen peroxide concentration. The corrosion controlling mechanism is thought to be the reaction of the oxide with the perhydroxyl ion. No evidence of thermodynamically stable calcium titanate was found in the surface film of test coupons exposed to calcium-inhibited alkaline peroxide solutions. Calcium inhibition is probably the result of low local alkali and peroxide concentrations at the metal surface produced by reaction of adsorbed calcium with hydrogen peroxide. It has been shown that the inhibiting effect of calcium is temporary, possibly through an effect of calcium on the chemical and/or physical stability of the surface oxide. Pulp is an effective and stable corrosion inhibitor. Raising the pulp concentration decreased the corrosion rate. The inhibiting effect of pulp may be related to the adsorption and interaction of the pulp fibers with H 2O2, thereby decreasing the peroxide concentration and rendering the solution less corrosive. The presence of both pulp and calcium led to higher corrosion rates than obtained by either one inhibitor alone. Replacement of hydrofluoric acid with alkaline peroxide for pickling of titanium was investigated. Titanium corrosion rates in alkaline peroxide exceeded those obtained in the conventional hydrofluoric acid bath. General corrosion was observed with extensive roughening of the surface giving a dull gray appearance. Preferred dissolution of certain crystallographic planes was investigated through the corrosion of a titanium single crystal. Whereas the overall effect on the corrosion rate was small

  13. Rapid prototyped porous nickel-titanium scaffolds as bone substitutes.

    Science.gov (United States)

    Hoffmann, Waldemar; Bormann, Therese; Rossi, Antonella; Müller, Bert; Schumacher, Ralf; Martin, Ivan; de Wild, Michael; Wendt, David

    2014-01-01

    While calcium phosphate-based ceramics are currently the most widely used materials in bone repair, they generally lack tensile strength for initial load bearing. Bulk titanium is the gold standard of metallic implant materials, but does not match the mechanical properties of the surrounding bone, potentially leading to problems of fixation and bone resorption. As an alternative, nickel-titanium alloys possess a unique combination of mechanical properties including a relatively low elastic modulus, pseudoelasticity, and high damping capacity, matching the properties of bone better than any other metallic material. With the ultimate goal of fabricating porous implants for spinal, orthopedic and dental applications, nickel-titanium substrates were fabricated by means of selective laser melting. The response of human mesenchymal stromal cells to the nickel-titanium substrates was compared to mesenchymal stromal cells cultured on clinically used titanium. Selective laser melted titanium as well as surface-treated nickel-titanium and titanium served as controls. Mesenchymal stromal cells had similar proliferation rates when cultured on selective laser melted nickel-titanium, clinically used titanium, or controls. Osteogenic differentiation was similar for mesenchymal stromal cells cultured on the selected materials, as indicated by similar gene expression levels of bone sialoprotein and osteocalcin. Mesenchymal stromal cells seeded and cultured on porous three-dimensional selective laser melted nickel-titanium scaffolds homogeneously colonized the scaffold, and following osteogenic induction, filled the scaffold's pore volume with extracellular matrix. The combination of bone-related mechanical properties of selective laser melted nickel-titanium with its cytocompatibility and support of osteogenic differentiation of mesenchymal stromal cells highlights its potential as a superior bone substitute as compared to clinically used titanium.

  14. Rapid prototyped porous nickel–titanium scaffolds as bone substitutes

    Directory of Open Access Journals (Sweden)

    Waldemar Hoffmann

    2014-06-01

    Full Text Available While calcium phosphate–based ceramics are currently the most widely used materials in bone repair, they generally lack tensile strength for initial load bearing. Bulk titanium is the gold standard of metallic implant materials, but does not match the mechanical properties of the surrounding bone, potentially leading to problems of fixation and bone resorption. As an alternative, nickel–titanium alloys possess a unique combination of mechanical properties including a relatively low elastic modulus, pseudoelasticity, and high damping capacity, matching the properties of bone better than any other metallic material. With the ultimate goal of fabricating porous implants for spinal, orthopedic and dental applications, nickel–titanium substrates were fabricated by means of selective laser melting. The response of human mesenchymal stromal cells to the nickel–titanium substrates was compared to mesenchymal stromal cells cultured on clinically used titanium. Selective laser melted titanium as well as surface-treated nickel–titanium and titanium served as controls. Mesenchymal stromal cells had similar proliferation rates when cultured on selective laser melted nickel–titanium, clinically used titanium, or controls. Osteogenic differentiation was similar for mesenchymal stromal cells cultured on the selected materials, as indicated by similar gene expression levels of bone sialoprotein and osteocalcin. Mesenchymal stromal cells seeded and cultured on porous three-dimensional selective laser melted nickel–titanium scaffolds homogeneously colonized the scaffold, and following osteogenic induction, filled the scaffold’s pore volume with extracellular matrix. The combination of bone-related mechanical properties of selective laser melted nickel–titanium with its cytocompatibility and support of osteogenic differentiation of mesenchymal stromal cells highlights its potential as a superior bone substitute as compared to clinically used

  15. [Study on biocompatibility of titanium alloys].

    Science.gov (United States)

    Kodama, T

    1989-06-01

    The biocompatibility of two different titanium alloys, Ti-6Al-4V ELI and Ti-5Al-2, 5Fe, and pure titanium were evaluated. The results were as follows: 1) Titanium alloys were implanted into the dorsal subcutaneous tissues of the Hartley guinea-pig for 12 weeks, immersed in calf serum or in Ringer's solution for 8 weeks. The surface changes of the titanium alloys were observed by SEM and the chemical composition was analyzed by XMA. No evident surface changes were found. 2) Three hundred mg, 200 mg and 100 mg of the powders of the tested materials were immersed in 2ml of Eagle's MEM, incubated for 1-7 days, 8-21 days and 22-70 days at 37 C degrees. The amount of metallic elements dissolved in the solutions was measured by ICP and AAS. The detected corrosion rates of V and Al contained in the solution, in which Ti-6Al-4V ELI 100 mg was immersed for 1-7 days, were 194.3 +/- 17.6 and 73.0 +/- 28, 1 pg/mg alloy/day, respectively. V was released more than Al. The amount of Ti was below the detectable limit. The solution Ti-5Al-2.5 Fe 100 mg immersed for 1-7 days contained 31.9 +/- 34.4 pg/mg alloy/day Fe and 25.7 +/- 6.3 pg/mg alloy/day Al. Only in the solution 300 mg immersed for 1-7 days was Ti detected at 1.4 pg/mg alloy/day. 3) By the bacterial mutation assay of Salmonella typhimurium TA 98, Salmonella typhimurium TA 100 and Escherichia coli WP2 uvrA, the solutions, in which the tested materials were immersed, were not found to be mutagenic. 4) By the UDS assay, the grain counts on autoradiography with the solutions, in which the tested materials were immersed, were not greater than the negative control. The results suggest an excellent corrosion resistance of the titanium alloys. Mutagenicity was negative by these mutation assays, indicating that the tested alloys and pure titanium are safe for humans and animals.

  16. Standard Method for Analyzing Gases in Titanium and Titanium Alloys. Standard Method for the Chemical Analysis of Titanium Alloys.

    Science.gov (United States)

    1982-10-28

    acid solution, a cupferron reaaent and copper reagent are used to precipate the titanium, tin, vana- dium, iron and zirconium, and trichloromethane is...alcolohol solution Trichloromethane : Sodium fluroide : solid 4 Sodium acetate buffer solution (PH5-6) : 2M. 60 grams of anhydrous sodium acetate are...milliliters). Add 20 milliliters of a 10% test solution of copper-iron, 5 milliliters of 20% copper test solution, 30 milliliters of trichloromethane , shake

  17. Corrosion of titanium in supercritical water oxidation environments

    Institute of Scientific and Technical Information of China (English)

    卢建树; 毛志远; 张九渊; 马淳安; 毛信表; 李肖华

    2002-01-01

    Supercritical water oxidation (SCWO) can effectively destroy many kinds of civilian and military wastes. The high temperature and high pressure SCWO operation conditions generate very corrosive environment that many engineering materials fail to withstand. Preliminary test shows that titanium may be a promising material in most of SCWO conditions. Commercially pure titanium is tested in four kinds of SCWO environments. Phenol, sodium dodecyl-benzosulfonate, n-amine phenol, and chlorpyrifos were chosen as typical target pollutants. The results show that titanium is only superficially attacked in the first three SCWO environments while in chlorpyrifos SCWO medium titanium is corroded. The corrosion is temperature dependent, with heavier corrosion occurring at near critical temperature. X-ray diffraction analysis shows that the corrosion products consist of titanium oxy- phosphates and titanium oxide, in which Ti5O4(PO4)4 is the main phase.

  18. Grafting modification on the surface of titanium dioxide by polystyrene

    Institute of Scientific and Technical Information of China (English)

    Wei Wu; Shouci Lu; Jianfeng Chen; Lei Shao; CheeKing Tan

    2003-01-01

    Based on the technology of titanium dioxide grafting modification with polystyrene (PS), the modification mechanisms are studied and the polystyrene-grafting states on the surface of titanium dioxide have been set up. Under the synergistic actions of mechanical force, chemistry and heat, macromolecular free radicals of PS are created, at the same time, the O-O bonds of titanium dioxide are broken and the oxide free radicals produced, and the numbers of oxygen atom are increased and crystal lattice defects rich electrons are formed on the surface of titanium dioxide. The radical polymerization is the main reaction between PS and titanium dioxide and C-O bonds form in the process of modification. Multi-sites chemical adsorption also exists besides grafting between PS and titanium dioxide.

  19. Characterization of Titanium-Containing Compounds in Gray Iron

    Institute of Scientific and Technical Information of China (English)

    ZENG Daxin; ZHANG Yuanhao; LIU Jianyong; HE Hanjun; HONG Xiaoxian

    2008-01-01

    Titanium produces different compounds in gray iron. In order to determine their characteristics, a scanning electron microscope, an energy dispersive X-ray spectroscopy, and an optical microscopy were used to analyze the morphology, distribution, and composition of titanium-containing compounds in metal-lographic specimens and machined surfaces in four gray irons. The results show that the titanium-containing compounds in the gray irons are complex compounds containing V, Nb, Mn, S, and other metals, depending on the concentration of these elements in the iron. The number of titanium-containing compounds increases with increasing Ti content in the gray iron. Most of the titanium-containing compounds are located in the peariite matrix, with some in the steadite and carbides. The results suggest that titanium-containing com-pounds reduce tool lifetime.

  20. Dry face milling of titanium alloys

    Institute of Scientific and Technical Information of China (English)

    Ahmed Hassan; Zhenqiang Yao

    2004-01-01

    In machining titanium alloys, cutting tools generally wear out very rapidly because of the high cutting temperature resulted from the low thermal conductivity and density of the work material. In order to increase the tool life, it is necessary to suppress the cutting heat as much as possible by applying an abundant amount of coolant, but this will entail serious techno-environmental and biological problems. To study the performance and avoid these limitations, a PVD-coated insert was used to the dry face mill of (α +β) titanium alloys. As a result it was found that the inserts exhibit an excellent cutting performance at low cutting speeds and feed rates, and there is no significant difference in the dominant insert failure mode between the wet and dry cutting in discontinuous cutting.

  1. Standard digital reference images for titanium castings

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 The digital reference images provided in the adjunct to this standard illustrate various types and degrees of discontinuities occurring in titanium castings. Use of this standard for the specification or grading of castings requires procurement of the adjunct digital reference images, which illustrate the discontinuity types and severity levels. They are intended to provide the following: 1.1.1 A guide enabling recognition of titanium casting discontinuities and their differentiation both as to type and degree through digital radiographic examination. 1.1.2 Example digital radiographic illustrations of discontinuities and a nomenclature for reference in acceptance standards, specifications and drawings. 1.2 The digital reference images consist of seventeen digital files each illustrating eight grades of increasing severity. The files illustrate seven common discontinuity types representing casting sections up to 1-in. (25.4-mm). 1.3 The reference radiographs were developed for casting sections up to 1...

  2. Amorphouslike diffraction pattern in solid metallic titanium

    DEFF Research Database (Denmark)

    Wang, Y.; Fang, Y.Z.; Kikegawa, T.;

    2005-01-01

    Amorphouslike diffraction patterns of solid elemental titanium have been detected under high pressure and high temperature using in situ energy-dispersive x-ray diffraction and a multianvil press. The onset pressure and the temperature of formation of amorphous titanium is found to be close...... to the alpha-beta-omega triple point in the P-T phase diagram. Amorphous Ti has been found to be thermally stable up to 1250 degrees C for at least 3 min at some pressures. By analyzing the conditions for producing amorphous elemental Zr and Ti, we observed a multi-phase-point amorphization phenomenon...... for preparing single-element bulk amorphous metals. The results reported may open a new way to preparing single-element bulk amorphous metals with a high thermal stability....

  3. Possible segregation caused by centrifugal titanium casting.

    Science.gov (United States)

    Watanabe, K; Okawa, S; Kanatani, M; Nakano, S; Miyakawa, O; Kobayashi, M

    1996-12-01

    The possibility of the segregation under solidification process using a centrifugal casting machine was investigated using an electron probe microanalyzer with elemental distribution map, line analysis and quantitative analysis. When a very small quantity of platinum was added to local molten titanium during the casting process, macroscopic segregation was observed under conditions of density difference of 0.1 g/cm3 at the most, confirming that the centrifugal force of the casting machine is extremely strong. When a Ti-6Al-4V alloy was cast, however, no macroscopic segregation was observed. The centrifugal force of the casting machine examined in the present study hardly results in the body-force segregation in this titanium alloy.

  4. Biocorrosion study of titanium-nickel alloys.

    Science.gov (United States)

    Chern Lin, J H; Lo, S J; Ju, C P

    1996-02-01

    The present study provides results of the corrosion behaviour in Hank's physiological solution and some other properties of three Ti-Ni alloys with 18, 25 and 28.4 wt% Ni, respectively. Results indicate that alpha-titanium and Ti2Ni were the two major phases in all three Ti-Ni alloys. The relative amount of the Ti2Ni phase increased with additional Ni content. Hardness of the Ti-Ni alloys also increased with added nickel content, ranging from 310 to 390 VHN, similar to the hardness of enamel. Melting temperatures of the Ti-Ni alloys were all lower than that of pure titanium by least 600 degrees C. The three Ti-Ni alloys behaved almost identically when potentiodynamically polarized in Hank's solution at 37 degrees C. The critical anodic current densities of the alloys were nearly 30 microA/cm2 and the breakdown potentials were all above 1100 mV (SCE).

  5. Microstructure and Slip Character in Titanium Alloys

    Directory of Open Access Journals (Sweden)

    D. Banerjee

    1986-04-01

    Full Text Available Influence of microstructures in titanium alloys on the basic parameters of deformation behaviour such as slip character, slip length and slip intensity have been explored. Commercial titanium alloys contain the hexagonal close packed (alpha and body centred cubic (bita phases. Slip in these individual phases is shown to be dependent on the nature of alloying elements through their effect on phase stability as related to decomposition into ordered or w structures. When alpha and bita coexist, their relative crystallographic orientations, size, shape and volume fraction, control the nature of slip. For a given composition, structure may be manipulated through appropriate thermomechanical treatment to obtain the desired deformation behaviour and therefore fracture mode.

  6. Fatigue - corrosion of endoprosthesis titanium alloys.

    Science.gov (United States)

    Cornet, A; Muster, D; Jaeger, J H

    1979-01-01

    Commercial total hip prostheses often show certain metallurgical faults (porosities, coarse grains, growth dendrites, carbide networks). In order to investigate more accurately the role played by these different parameters in prostheses failure we performed a large number of systematic corrosion, fatigue and fatigue - corrosion tests on these materials and on commercial total hip prostheses. Ultimate strengthes seem to be reached for cast cobalt alloys, whereas titanium alloys, such as Ta 6 V, present very high fatigue limit under corrosion. Thus, rotative bending fatigue - corrosion tests in biological environment provide values about 50 DaN/mm2. This value, is nevertheless appreciably higher than those obtained with stellites and stainless steel. Titanium alloys, because of their mechanical performances, their weak Young's modulus (11000 DaN/mm2) and their relative lightness (4.5. g/cm3), which are associated with a good biocompatibility, seem very promising for permanent implants realisation.

  7. On Silicides in High Temperature Titanium Alloys

    Directory of Open Access Journals (Sweden)

    C. Ramachandra

    1986-04-01

    Full Text Available High temperature titanium alloys like IMI 685 contain small amounts of silicon (~ 0.25 wt. per cent to improve creep resistance. Different types of silicides, namely Ti5Si3 (TiZr5Si3(S1 and (TiZr6 Si3 (S2, have been observed to precipitate in various silicon-bearing titanium alloys depending upon their composition and heat treatment. The precipitation of silicides, their orientation relationship with the matrix in different alloys, and the beneficial influence of thermo-mechanical treatment on the distribution of silicides have been pointed out. The effect of silicides on mechanical properties and fracture of the commercial alloy IMI 685 is also indicated.

  8. Hydrogen behavior in titanium aluminide alloys

    Institute of Scientific and Technical Information of China (English)

    PAN Bao-wu; CHU Wu-yang

    2006-01-01

    This is a synthetical report about hydrogen behavior in titanium aluminide alloys in our group. There are two kinds of hydrogen solubility in titanium aluminides, one is the overall solubility at high temperature in the matrix without hydride and the other is the terminal solubility at low temperature in the matrix in equilibrium with the hydride. The former decreases but the later increases with increasing temperature. Hydrogen as a temporary β stabilizer clearly decreases the size of the α2 phase, and increases greatly the amount of β phase, and then increases evidently the mechanical properties of Ti3Al+Nb. The cathodic corrosion of TiAl during charging is due to hydride on the surface. The decrease of the strength, the strain to fracture and fracture toughness for hydrogenated samples is due to hydride. The enrichment of atomic hydrogen at the crack tip during charging under sustained load can enhance localized plastic deformation and cause hydrogen-induced delayed cracking.

  9. Biomimetic Multispiked Connecting Ti-Alloy Scaffold Prototype for Entirely-Cementless Resurfacing Arthroplasty Endoprostheses—Exemplary Results of Implantation of the Ca-P Surface-Modified Scaffold Prototypes in Animal Model and Osteoblast Culture Evaluation

    Directory of Open Access Journals (Sweden)

    Ryszard Uklejewski

    2016-06-01

    Full Text Available We present here—designed, manufactured, and tested by our research team—the Ti-alloy prototype of the multispiked connecting scaffold (MSC-Scaffold interfacing the components of resurfacing arthroplasty (RA endoprostheses with bone. The spikes of the MSC-Scaffold prototype mimic the interdigitations of the articular subchondral bone, which is the natural biostructure interfacing the articular cartilage with the periarticular trabecular bone. To enhance the osteoinduction/osteointegration potential of the MSC-Scaffold, the attempts to modify its bone contacting surfaces by the process of electrochemical cathodic deposition of Ca-P was performed with further immersion of the MSC-Scaffold prototypes in SBF in order to transform the amorphous calcium-phosphate coating in hydroxyapatite-like (HA-like coating. The pilot experimental study of biointegration of unmodified and Ca-P surface-modified MSC-Scaffold prototypes was conducted in an animal model (swine and in osteoblast cell culture. On the basis of a microscope-histological method the biointegration was proven by the presence of trabeculae in the interspike spaces of the MSC-Scaffold prototype on longitudinal and cross-sections of bone-implant specimens. The percentage of trabeculae in the area between the spikes of specimen containing Ca-P surface modified scaffold prototype observed in microCT reconstructions of the explanted joints was visibly higher than in the case of unmodified MSC-Scaffold prototypes. Significantly higher Alkaline Phosphatase (ALP activity and the cellular proliferation in the case of Ca-P-modified MSC-Scaffold pre-prototypes, in comparison with unmodified pre-prototypes, was found in osteoblast cell cultures. The obtained results of experimental implantation in an animal model and osteoblast cell culture evaluations of Ca-P surface-modified and non-modified biomimetic MSC-Scaffold prototypes for biomimetic entirely-cementless RA endoprostheses indicate the

  10. Influence of radiation on titanium dioxide memristors

    OpenAIRE

    Vujisić, M.; Marjanović, N.; Fetahović, I.; id_orcid 0000-0001-5788-1273; Stanković, K.; Osmokrović, P.

    2012-01-01

    Effects of titanium dioxide memristor exposure to proton and ion beams are investigated. A memristor model assuming ohmic electronic conduction and linear ionic drift is used for the analysis. Simulations of particle transport suggest that radiation induced oxygen ion/oxygen vacancy pairs can influence the device’s operation by lowering both the mobility of the vacancies and the resistance of the stoichiometric oxide region. These radiation induced changes affect the current-voltage character...

  11. Powder processing of hybrid titanium neural electrodes

    Science.gov (United States)

    Lopez, Jose Luis, Jr.

    A preliminary investigation into the powder production of a novel hybrid titanium neural electrode for EEG is presented. The rheological behavior of titanium powder suspensions using sodium alginate as a dispersant are examined for optimal slip casting conditions. Electrodes were slip cast and sintered at 950°C for 1 hr, 1000°C for 1, 3, and 6 hrs, and 1050°C for 1 hr. Residual porosities from sintering are characterized using Archimedes' technique and image analysis. The pore network is gel impregnated by submerging the electrodes in electrically conductive gel and placing them in a chamber under vacuum. Gel evaporation of the impregnated electrodes is examined. Electrodes are characterized in the dry and gelled states using impedance spectrometry and compared to a standard silver- silver chloride electrode. Power spectral densities for the sensors in the dry and gelled state are also compared. Residual porosities for the sintered specimens were between 50.59% and 44.81%. Gel evaporation tests show most of the impregnated gel evaporating within 20 min of exposure to atmospheric conditions with prolonged evaporation times for electrodes with higher impregnated gel mass. Impedance measurements of the produced electrodes indicate the low impedance of the hybrid electrodes are due to the increased contact area of the porous electrode. Power spectral densities of the titanium electrode behave similar to a standard silver-silver chloride electrode. Tests suggest the powder processed hybrid titanium electrode's performance is better than current dry contact electrodes and comparable to standard gelled silver-silver chloride electrodes.

  12. Free Form Low Cost Fabrication Using Titanium

    Science.gov (United States)

    2007-06-29

    Metals", 2006 Edition, Annex F "Supplementary Information on Titanium" "* Terry T. Wohlers , Wohlers Report 2005 "Rapid Prototyping, Tooling...Manufacturing State of the Industry Annual Worldwide Progress Report ", 2005, Wohlers Associates "* R.M. German, "Sintering Theory and Practice", 1996, John Wiley & Sons, Inc. Page 52 ...Metals, Inc., of Nashua, NH. Further descriptions of these powders can be found in subsequent sections of this report The following table contains

  13. Coating, Titanium Dioxide and Solar Cell

    OpenAIRE

    Yang, Aohan

    2011-01-01

    The objective of this bachelor’s thesis is to get basic ideas about coating and a deep understanding of properties of titanium dioxide pigments as well as their application and performance in solar electricity energy technology. This thesis consists of three main parts, eight chapters. The first part is about basic knowledge of coating and tests of coated paper. Coating pigments are generally introduced in the part. In the second part, coating additives are introduced in details from ...

  14. Anomalous thermal expansion in $\\alpha$-titanium

    OpenAIRE

    Souvatzis, P.; O. Eriksson; M. I. Katsnelson

    2007-01-01

    We provide a complete quantitative explanation for the anisotropic thermal expansion of hcp Ti at low temperature. The observed negative thermal expansion along the c-axis is reproduced theoretically by means of a parameter free theory which involves both the electron and phonon contributions to the free energy. The thermal expansion of titanium is calculated and found to be negative along the c-axis for temperatures below $\\sim$ 170 K, in good agreement with observations. We have identified ...

  15. Fabrication of titanium oxide nanotube arrays by anodic oxidation

    Science.gov (United States)

    Zhao, Jianling; Wang, Xiaohui; Chen, Renzheng; Li, Longtu

    2005-06-01

    The formation of titanium oxide nanotube arrays on titanium substrates was investigated in HF electrolytes. Under optimized electrolyte and oxidation conditions, well-ordered nanotubes of titania were fabricated. Topologies of the anodized titanium change remarkably along with the changing of applied voltages, electrolyte concentration and oxidation time. Electrochemical determination and scanning electron microscope indicate the nanotubes are formed due to the competition of titania formation and dissolution under the assistance of electric field. A possible growth mechanism has also been presented.

  16. Processing of Elemental Titanium by Powder Metallurgy Techniques

    OpenAIRE

    Bolzoni, Leandro; Ruiz Navas, Elisa María; Gordo Odériz, Elena

    2013-01-01

    [Poster] 6th International Light Metals Technology Conference (LMT2013), 24-26 July, Windsord (UK) Titanium is characterised by an outstanding combination of properties like high strength, low density, good corrosion resistance and biocompatibility. Nonetheless, widespread employment of titanium at the industrial level, especially in the automotive industry, has not been achieved yet because of its high extraction and production costs. Consequently, titanium finds applications mainly in hi...

  17. Clinical performance of machined titanium restorations.

    Science.gov (United States)

    Walter, M; Böning, K; Reppel, P D

    1994-12-01

    In 37 patients 88 titanium restorations were placed during a 1-year period 1990-91. The 69 crowns and 19 fixed partial dentures comprised 147 prosthodontic units. All restorations were fabricated by duplication milling and electrical discharge machining of pure titanium (Procera Technology, Nobelpharma, Gothenburg, Sweden). Based on the results of clinical follow-up, Kaplan-Meier survivor functions were calculated. The survivor rate of 40 metal crowns and pontics was 100%. In 107 porcelain-fused-to-metal units the 3-year survivor rate concerning removal was 95%. When relating the survival to an intact ceramic veneer, the 3-year survivor rate of porcelain-fused-to-metal units was 84%. The quality of the restorations evaluated by the rating system of the California Dental Association was found to be satisfactory in the vast majority of cases. It can be concluded that machined titanium restorations are suitable for clinical use, although not all problems, especially in the field of metal-ceramics have yet been completely solved.

  18. Progress in Titanium Metal Powder Injection Molding

    Directory of Open Access Journals (Sweden)

    Randall M. German

    2013-08-01

    Full Text Available Metal powder injection molding is a shaping technology that has achieved solid scientific underpinnings. It is from this science base that recent progress has occurred in titanium powder injection molding. Much of the progress awaited development of the required particles with specific characteristics of particle size, particle shape, and purity. The production of titanium components by injection molding is stabilized by a good understanding of how each process variable impacts density and impurity level. As summarized here, recent research has isolated the four critical success factors in titanium metal powder injection molding (Ti-MIM that must be simultaneously satisfied—density, purity, alloying, and microstructure. The critical role of density and impurities, and the inability to remove impurities with sintering, compels attention to starting Ti-MIM with high quality alloy powders. This article addresses the four critical success factors to rationalize Ti-MIM processing conditions to the requirements for demanding applications in aerospace and medical fields. Based on extensive research, a baseline process is identified and reported here with attention to linking mechanical properties to the four critical success factors.

  19. Titanium diffusion in gold thin films

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, William E. [Materials Department, University of California, Santa Barbara, CA 93106-5050 (United States); Gregori, Giuliano, E-mail: g.gregori@fkf.mpg.d [California NanoSystems Institute, University of California, Santa Barbara, CA 93106-5050 (United States); Mates, Thomas [Materials Department, University of California, Santa Barbara, CA 93106-5050 (United States)

    2010-03-01

    In the present study, diffusion phenomena in titanium/gold (Ti/Au) thin films occurring at temperatures ranging between 200 and 400 {sup o}C are investigated. The motivation is twofold: the first objective is to characterize Ti diffusion into Au layer as an effect of different heat-treatments. The second goal is to prove that the implementation of a thin titanium nitride (TiN) layer between Ti and Au can remarkably reduce Ti diffusion. It is observed that Ti atoms can fully diffuse through polycrystalline Au thin films (260 nm thick) already at temperatures as a low as 250 {sup o}C. Starting from secondary ion mass spectroscopy data, the overall diffusion activation energy {Delta}E = 0.66 eV and the corresponding pre-exponential factor D{sub 0} = 5 x 10{sup -11} cm{sup 2}/s are determined. As for the grain boundary diffusivity, both the activation energy range 0.54 < {Delta}E{sub gb} < 0.66 eV and the pre-exponential factor s{sub 0}D{sub gb0} = 1.14 x 10{sup -8} cm{sup 2}/s are obtained. Finally, it is observed that the insertion of a thin TiN layer (40 nm) between gold and titanium acts as an effective diffusion barrier up to 400 {sup o}C.

  20. A sourcebook of titanium alloy superconductivity

    CERN Document Server

    Collings, E W

    1983-01-01

    In less than two decades the concept of supercon­ In every field of science there are one or two ductivity has been transformed from a laboratory individuals whose dedication, combined with an innate curiosity to usable large-scale applications. In the understanding, permits them to be able to grasp, late 1960's the concept of filamentary stabilization condense, and explain to the rest of us what that released the usefulness of zero resistance into the field is all about. For the field of titanium alloy marketplace, and the economic forces that drive tech­ superconductivity, such an individual is Ted Collings. nology soon focused on niobium-titanium alloys. They His background as a metallurgist has perhaps given him are ductile and thus fabricable into practical super­ a distinct advantage in understanding superconduc­ conducting wires that have the critical currents and tivity in titanium alloys because the optimization of fields necessary for large-scale devices. More than superconducting parameters in ...

  1. [Guided bone regeneration beneath titanium foils].

    Science.gov (United States)

    Otto, Katharina; Schopper, Christian; Ewers, Rolf; Lambrecht, J Thomas

    2004-01-01

    The aim of this study was to examine the clinical and histological bony healing process beneath titanium foils used for guided tissue regeneration as well as of the Frios Algipore graft which was applied with autologous bone. 66 sinus floor elevations were carried out and examined over a period of three years and eight months. A success rate of 64% was recorded with foil incorporation. Complications occurred in form of primary and secondary disturbances in the healing process caused by exposure of the foil. 12 of the 66 foils had to be removed early. In all but one case, the augmented bone material was macroscopically well integrated despite the loss of the foil. Primary stability of the inserted dental implants into the ossified augmented site after operations of the sinus maxillaris was reached in all cases with absence of post-operative complications, and in 94% when there was postoperative exposure of the membrane. Histologically, a thin layer of connective tissue poor in cells but rich in collagen fibers appeared underneath the titanium foil. This was followed by newly-formed bony tissue transforming into osseous lamella parallel to the membrane underneath the new periost. In 65 out of 66 cases a sufficient amount of stable bone was built up locally suggesting good bio-compatibility and barrier function. Further, the foil also provided mechanical rest and supporting function for the space underneath. However, the occurrence of healing complications in 36% of the cases showed a need to improve on the titanium foils.

  2. Preparation of titanium diboride powders from titanium alkoxide and boron carbide powder

    Indian Academy of Sciences (India)

    Hamed Sinaei Pour Fard; Hamidreza Baharvandi

    2011-07-01

    Titanium diboride powders were prepared through a sol–gel and boron carbide reduction route by using TTIP and B4C as titanium and boron sources. The influence of TTIP concentration, reaction temperature and molar ratio of precursors on the synthesis of titanium diboride was investigated. Three different concentrations of TTIP solution, 0.033/0.05/0.1, were prepared and the molar ratio of B4C to TTIP varied from 1.3 to 2.5. The results indicated that as the TTIP concentration had an important role in gel formation, the reaction temperature and B4C to TTIP molar ratio showed obvious effects on the formation of TiB2. Pure TiB2 was prepared using molar composition of Ti : B4C = 1 : 2.3 and the optimum synthesis temperature was 1200°C.

  3. Improved photocatalytic degradation of textile dye using titanium dioxide nanotubes formed over titanium wires.

    Science.gov (United States)

    Kar, Archana; Smith, York R; Subramanian, Vaidyanathan

    2009-05-01

    Titanium dioxide (TiO2) nanotubes formed by anodization over titanium wires show a significant improvement in photocatalytic activity compared to the nanotubes formed over foils. This is evident when the fractional conversion of a textile dye, methyl orange, increased from 19% over a foil to 40% over wires in the presence of nanotubes of identical dimensions illuminated over the same geometrical area. Higher degradation rates with Pt-TiO2 nanotubes over foils are matched by the Pt-free TiO2 nanotubes over the wires. The higher photocatalytic activity over the anodized wires can be attributed to the efficient capture of reflected and refracted light by the radially outward oriented TiO2 nanotubes formed over the circumference of the titanium wire. The formation of TiO2 nanotubes over wires can be considered as an effective alternate to improve photodegradation rates by avoiding expensive additives.

  4. Processing of TiO2 from titanium-bearing blast furnace slag as titanium source

    Directory of Open Access Journals (Sweden)

    X. Li

    2016-07-01

    Full Text Available The titanium dioxide(TiO2 was prepared by efficient decomposition of titanium- bearing blast furnace slag (TBBFS in molten salt system. The as-prepared TiO2 were characterized by X-ray diffraction (XRD and scanning electron microscopy (SEM. Almost complete leaching of Ti was achieved when TBBFS was carried out at 500 °C for about 3 h with NaOH/TBBFS mass ratio of 3:1 and NaOH to NaF molar ratio of 3:1. The XRD pattern showed that the containing titanium product obtained under optimal conditions was Na2TiO3. The average size of the rutile TiO2 obtained was about 1.0μm and the content was up to 99,23 %.

  5. Cold Spraying of Armstrong Process Titanium Powder for Additive Manufacturing

    Science.gov (United States)

    MacDonald, D.; Fernández, R.; Delloro, F.; Jodoin, B.

    2016-12-01

    Titanium parts are ideally suited for aerospace applications due to their unique combination of high specific strength and excellent corrosion resistance. However, titanium as bulk material is expensive and challenging/costly to machine. Production of complex titanium parts through additive manufacturing looks promising, but there are still many barriers to overcome before reaching mainstream commercialization. The cold gas dynamic spraying process offers the potential for additive manufacturing of large titanium parts due to its reduced reactive environment, its simplicity to operate, and the high deposition rates it offers. A few challenges are to be addressed before the additive manufacturing potential of titanium by cold gas dynamic spraying can be reached. In particular, it is known that titanium is easy to deposit by cold gas dynamic spraying, but the deposits produced are usually porous when nitrogen is used as the carrier gas. In this work, a method to manufacture low-porosity titanium components at high deposition efficiencies is revealed. The components are produced by combining low-pressure cold spray using nitrogen as the carrier gas with low-cost titanium powder produced using the Armstrong process. The microstructure and mechanical properties of additive manufactured titanium components are investigated.

  6. Preparation and characterization of nitrogen-doped titanium dioxides

    Institute of Scientific and Technical Information of China (English)

    ZHU GuoPing; ZHOU KangGen

    2007-01-01

    A type of high visible-light active titanium oxinitride (TiO2_xNx) powder was prepared by a simple process: the calcination of the hydrated titanium dioxide at the atmosphere of ammonia-argon using a tubular electric furnace at high temperatures. The hydrated titanium dioxide was synthesized as the precursor of TiO2_xNx using titanic acid as raw material, which came from sulfate technique of producing titanium white. The effects of temperature and reaction time on the nitrogen content, grain size and crystal structure were studied. The visible-light activity and photocatalysis capability of the powder were also investigated.

  7. Characterization of Pectin Nanocoatings at Polystyrene and Titanium Surfaces

    DEFF Research Database (Denmark)

    Gurzawska, Katarzyna; Dirscherl, Kai; Yihua, Yu;

    2013-01-01

    study was to physically characterize and compare polystyrene and titanium surfaces nanocoated with different Rhamnogalacturonan-Is (RG-I) and to visualize RG-I nanocoatings. RG-Is from potato and apple were coated on aminated surfaces of polystyrene, titianium discs and titanium implants...... wettability, without any major effect on surface roughness (Sa, Sdr). Furthermore, we demonstrated that it is possible to visualize the pectin RG-Is molecules and even the nanocoatings on titanium surfaces, which have not been presented before. The comparison between polystyrene and titanium surface showed...

  8. Granulomatous disease associated with pulmonary deposition of titanium.

    Science.gov (United States)

    Redline, S; Barna, B P; Tomashefski, J F; Abraham, J L

    1986-10-01

    A patient presented with granulomatous lung disease associated with the pulmonary deposition of various metallic particles. To evaluate the relation between the metallic dust and the granulomatous process, lymphocyte transformation tests to aluminium sulphate, titanium chloride, beryllium sulphate, and nickel sulphate were performed. A lymphocyte proliferative response to titanium chloride was observed on two separate occasions; no responses to the other metals were shown. These results are consistent with hypersensitivity to titanium, and suggest, in this individual, a possible aetiological role between the inhalation of titanium and a granulomatous disease process.

  9. Numerical assessment of bone remodeling around conventionally and early loaded titanium and titanium-zirconium alloy dental implants.

    Science.gov (United States)

    Akça, Kıvanç; Eser, Atılım; Çavuşoğlu, Yeliz; Sağırkaya, Elçin; Çehreli, Murat Cavit

    2015-05-01

    The aim of this study was to investigate conventionally and early loaded titanium and titanium-zirconium alloy implants by three-dimensional finite element stress analysis. Three-dimensional model of a dental implant was created and a thread area was established as a region of interest in trabecular bone to study a localized part of the global model with a refined mesh. The peri-implant tissues around conventionally loaded (model 1) and early loaded (model 2) implants were implemented and were used to explore principal stresses, displacement values, and equivalent strains in the peri-implant region of titanium and titanium-zirconium implants under static load of 300 N with or without 30° inclination applied on top of the abutment surface. Under axial loading, principal stresses in both models were comparable for both implants and models. Under oblique loading, principal stresses around titanium-zirconium implants were slightly higher in both models. Comparable stress magnitudes were observed in both models. The displacement values and equivalent strain amplitudes around both implants and models were similar. Peri-implant bone around titanium and titanium-zirconium implants experiences similar stress magnitudes coupled with intraosseous implant displacement values under conventional loading and early loading simulations. Titanium-zirconium implants have biomechanical outcome comparable to conventional titanium implants under conventional loading and early loading.

  10. Silica containing highly porous alumina ceramic

    Science.gov (United States)

    Svinka, R.; Svinka, V.; Zake, I.

    2011-04-01

    Porous alumina ceramic were produced by slip casting of aqueous alumina slurry with added small amount of metallic aluminium powder. Pores form in result of chemical reaction of aluminum with water by hydrogen gas evolution reaction and solidification of suspension. Porosity of such materials sintered at a temperature of 1600 - 1750°C varies from 60 to 90%. Pore size distribution and mechanical strength of these materials depend largely on the grain size of used raw materials. The major part of pores in the materials produced without additive of silica are larger than 10 ±m, but with 5 - 10 wt.% additive of silica in the raw mix pore size decreases considerably. The sintering shrinkage decreases to 2.5%. Coefficient of thermal expansion equally decreases from 8.9-10-6 K-1 to 7.1 10-6 K-1 and classification temperature increases to 1600°C, while deformation at high temperature decreases considerably.

  11. The assessment of ultrasonic tests as a tool for qualification and diagnostic study of traditional highly porous and soft stone materials used in the built heritage of the past.

    Science.gov (United States)

    Calia, A.; Sileo, M.; Leucci, G.

    2012-04-01

    Ultrasonic tests are performing tools for the quality assessment and selection of stone as building materials, as well as for the detection of faults within architectural and structural elements. The use of the non destructive and non invasive diagnostic techniques has always advantages in the activities on pre-existing buildings, in terms of sustainability; moreover, it is a need with respect to the conservation constraints when we act on the historical-architectural heritage. Ultrasonic technique is widely and successfully performed in the diagnosis and control of the restoration works on concrete and compact stone artefacts. Specific problems arise from its use with reference to highly porous and soft stones, in particular bi-component materials with grains-cement binder structure, such as calcarenites. Low ultrasonic propagation velocity, typically associated to the soft and porous materials can be easily affected by disturbing factors, in primis water (in vapour or liquid state), that can easily and frequently penetrates inside them and in significant amounts, due to their high open porosity. The analysis and interpretation of the data acquired by in situ investigations have to take into account this additional contribution. In the same way, on site structures and materials can be easily interested by salt presence and deposition within the pores, that can furtherly interfere on the data significance, as well as it is important to know the variability of data due to the different state of conservation of the stones. The influence of all these factors on the response to the ultrasonic tests needs to be investigated by laboratory controlled conditions, preliminarily to the in situ application. The present work refers to the experimental activity devoted to investigate the critical aspects that have been mentioned above and the results obtained. It is a part of a larger activity with the final aim to set up non invasive diagnostic procedures for the analysis and

  12. Effect of titanium nitride/titanium coatings on the stress corrosion of nickel-titanium orthodontic archwires in artificial saliva

    Science.gov (United States)

    Liu, Jia-Kuang; Liu, I.-Hua; Liu, Cheng; Chang, Chen-Jung; Kung, Kuan-Chen; Liu, Yen-Ting; Lee, Tzer-Min; Jou, Jin-Long

    2014-10-01

    The purpose of this investigation was to develop titanium nitride (TiN)/titanium (Ti) coating on orthodontic nickel-titanium (NiTi) wires and to study the stress corrosion of specimens in vitro, simulating the intra-oral environment in as realistic a manner as possible. TiN/Ti coatings were formed on orthodontic NiTi wires by physical vapor deposition (PVD). The characteristics of untreated and TiN/Ti-coated NiTi wires were evaluated by measurement of corrosion potential (Ecorr), corrosion current densities (Icorr), breakdown potential (Eb), and surface morphology in artificial saliva with different pH and three-point bending conditions. From the potentiodynamic polarization and SEM results, the untreated NiTi wires showed localized corrosion compared with the uniform corrosion observed in the TiN/Ti-coated specimen under both unstressed and stressed conditions. The bending stress influenced the corrosion current density and breakdown potential of untreated specimens at both pH 2 and pH 5.3. Although the bending stress influenced the corrosion current of the TiN/Ti-coated specimens, stable and passive corrosion behavior of the stressed specimen was observed even at 2.0 V (Ag/AgCl). It should be noted that the surface properties of the NiTi alloy could determine clinical performance. For orthodontic application, the mechanical damage destroys the protective oxide film of NiTi; however, the self-repairing capacity of the passive film of NiTi alloys is inferior to Ti in chloride-containing solutions. In this study, the TiN coating was found able to provide protection against mechanical damage, while the Ti interlayer improved the corrosion properties in an aggressive environment.

  13. Comparative assessment of short term outcome of cementless prosthesis versus cemented femoral stem prosthesis in hip arthroplasty for elderly intertrochanteric fracture%生物型与骨水泥型人工髋关节置换治疗高龄转子间骨折早期疗效的比较

    Institute of Scientific and Technical Information of China (English)

    闫文龙; 杨小中; 张华; 张健

    2015-01-01

    Objective To compare the short-term clinical effect of the distal fixed prosthesis ( cementless prosthesis ) with cemented femoral stem prosthesis in hip arthroplasty for elderly intertrochanteric fracture .Methods Fifty-nine cases(54 cases followed-up) of unilateral intertrochanteric fracture in senile patients from Aug .2010 to Apr.2012 were retrospectively analyzed and randomly divided into 2 groups.In them,21 cases underwent hip ar-throplasty using the distal fixed prosthesis ( cementless group ) ,and the other 33 were treated with cemented hip ar-throplasty (cement group).The difference was compared in time of hospitalization , time of operation,blood loss, adverse effect,Harris scoring and radiological results .Results The average operation time were (42.3 ±7.2) mi-nutes in cementless group and (51.5 ±8.3) minutes in cement group,with significant difference (P0.05).Conclu-sion Hip arthroplasty using cementless prosthesis for treatment of elder patients with intertrochanteric fracture can a -chieve good short-term clinical effect alike cemented prosthesis .It helps reduce operative time ,blood loss and bone cement implantation syndrome during the operation .The medium and long term effect still needs further research . And preoperative evaluation on the shape and size of medullary cavity and the severity of osteoporosis is needed .%目的:比较远端固定生物型股骨假体与骨水泥型股骨假体行人工髋关节置换治疗高龄股骨转子间骨折的早期临床疗效。方法回顾性分析2010年8月~2012年4月在我院骨科行人工髋关节置换治疗的59例单侧股骨转子间骨折高龄患者的临床资料,实际随访54例。随机分成两组:生物固定组21例,骨水泥组33例。比较两组住院时间、手术时间、术中出血量、术后3d总失血量、术后并发症、Harris评分以及放射学效果。结果生物固定组手术时间、术中出血均明显少于骨水泥组;生物固定组术中、

  14. In situ formation of titanium carbide using titanium and carbon-nanotube powders by laser cladding

    Energy Technology Data Exchange (ETDEWEB)

    Savalani, M.M., E-mail: mmfsmm@inet.polyu.edu.hk [Department of Industrial and Systems Engineering, Hong Kong Polytechnic University (Hong Kong); Ng, C.C.; Li, Q.H.; Man, H.C. [Department of Industrial and Systems Engineering, Hong Kong Polytechnic University (Hong Kong)

    2012-01-15

    Titanium metal matrix composite coatings are considered to be important candidates for high wear resistance applications. In this study, TiC reinforced Ti matrix composite layers were fabricated by laser cladding with 5, 10, 15 and 20 wt% carbon-nanotube. The effects of the carbon-nanotube content on phase composition, microstructure, micro-hardness and dry sliding wear resistance of the coating were studied. Microstructural observation using scanning electron microscopy showed that the coatings consisted of a matrix of alpha-titanium phases and the reinforcement phase of titanium carbide in the form of fine dendrites, indicating that titanium carbide was synthesized by the in situ reaction during laser irradiation. Additionally, measurements on the micro-hardness and dry sliding wear resistance of the coatings indicated that the mechanical properties were affected by the amount of carbon-nanotube in the starting precursor materials and were enhanced by increasing the carbon-nanotube content. Results indicated that the composite layers exhibit high hardness and excellent wear resistance.

  15. Titanium Carbide-Nickel Cermets: Processing and Joing

    Science.gov (United States)

    1952-03-01

    Titanium carbide -nickel cermets can be sintered to have transverse rupture strengths over 250,000 pounds per square inch. To do so, four principal...enough to allow thorough degassing. Joining titanium - carbide cermets to high-temperature alloys has been accomplished by vacuum diffusion, and gives

  16. TITANIUM CARBIDE CONTENT EFFECT ON EROSION IN CERMET ROCKET NOZZLES

    Science.gov (United States)

    class investigated consisted of an AISI Type 316 stainless steel matrix incorporating a hard phase of titanium carbide ranging in content from 20% to...55% by volume. The results of the study indicated that under the test conditions, increases in the titanium carbide constituents did increase the

  17. 40 CFR 721.10021 - Magnesium potassium titanium oxide.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Magnesium potassium titanium oxide... Specific Chemical Substances § 721.10021 Magnesium potassium titanium oxide. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as magnesium...

  18. The effect of chemotherapeutic agents on titanium-adherent biofilms

    NARCIS (Netherlands)

    Ntrouka, V.; Hoogenkamp, M.; Zaura, E.; van der Weijden, F.

    2011-01-01

    Objective: To assess the effectiveness of different chemotherapeutic agents on biofilm-contaminated titanium surfaces. Material and methods: This study used a recently described biofilm model. In experiment 1, Streptococcus mutans biofilms grown on titanium discs were treated with (1) EDTA, (2) citr

  19. Vanadium-pumped titanium x-ray laser

    Energy Technology Data Exchange (ETDEWEB)

    Nilsen, J.

    1991-02-13

    A resonantly photo-pumped x-ray laser is formed of a vanadium and titanium foil combination that is driven by two beams of intense line focused optical laser radiation. Ground state neon-like titanium ions are resonantly photo-pumped by line emission from fluorine-like vanadium ions.

  20. Classification of titanium dioxide; Clasificacion del dioxido de titanio

    Energy Technology Data Exchange (ETDEWEB)

    Macias B, L.R. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Garcia C, R.M.; Maya M, M.E. [Secretaria de Hacienda y Credito Publico de Mexico, Mexico (Mexico); Ita T, A. De [Universidad Autonoma Metropolitana Azcapotzalco, Mexico (Mexico); Palacios G, J. [Instituto Politecnico Nacional (Mexico)

    2002-07-01

    In this work the X-ray diffraction (XRD), Scanning Electron Microscopy (Sem) and the X-ray Dispersive Energy Spectroscopy techniques are used with the purpose to achieve a complete identification of phases and mixture of phases of a crystalline material as titanium dioxide. The problem for solving consists of being able to distinguish a sample of titanium dioxide being different than a titanium dioxide pigment. A standard sample of titanium dioxide with NIST certificate is used, which indicates a purity of 99.74% for the TiO{sub 2}. The following way is recommended to proceed: a)To make an analysis by means of X-ray diffraction technique to the sample of titanium dioxide pigment and on the standard of titanium dioxide waiting not find differences. b) To make a chemical analysis by the X-ray Dispersive Energy Spectroscopy via in a microscope, taking advantage of the high vacuum since it is oxygen which is analysed and if it is concluded that the aluminium oxide appears in a greater proportion to 1% it is established that is a titanium dioxide pigment, but if it is lesser then it will be only titanium dioxide. This type of analysis is an application of the nuclear techniques useful for the tariff classification of merchandise which is considered as of difficult recognition. (Author)

  1. Characterization of Pectin Nanocoatings at Polystyrene and Titanium Surfaces

    DEFF Research Database (Denmark)

    Gurzawska, Katarzyna; Dirscherl, Kai; Yihua, Yu

    2013-01-01

    wettability, without any major effect on surface roughness (Sa, Sdr). Furthermore, we demonstrated that it is possible to visualize the pectin RG-Is molecules and even the nanocoatings on titanium surfaces, which have not been presented before. The comparison between polystyrene and titanium surface showed...

  2. High temperature thermodynamics and vaporization of stoichiometric titanium monoxide

    Energy Technology Data Exchange (ETDEWEB)

    Sheldon, R.I.; Gilles, P.W.

    1976-08-17

    Three vaporization experiments were performed on samples of nearly stoichiometric titanium monoxide. Two experiments were constant temperature experiments (1806/sup 0/K) designed to measure the equilibrium vapor pressures of Ti(g) and TiO(g). In one experiment titanium monoxide was vaporized from a tungsten Knudsen effusion cell; the vapor was collected on a water cooled quartz cap surrounding the cell; and the total amount of titanium deposited on the cap was analyzed colorimetrically. In the second constant temperature experiment (1806/sup 0/K) the vapor composition in equilibrium with nearly stoichiometric titanium monoxide was measured mass spectrometrically. The mass spectrometer results were used to apportion the total titanium collected in the first experiment to Ti(g) and TiO(g). In the third experiment the temperature dependence of the ions Ti/sup +/(48) and TiO(64) was measured spectrometrically. The results obtained in this work are compared with published thermodynamic properties of the titanium oxygen system, and indicate the standard free energy of formation of titanium monoxide obtained from the earliest calorimetric measurements yielded a result not negative enough and also oxygen pressures obtained by emf measurements for stoichiometric titanium monoxide at 1806/sup 0/K are high by a factor of 42.6. The present results are in good agreement with the thermodynamic properties reported in recently issued pages of the JANAF Thermochemical Tables.

  3. UV photofunctionalization promotes nano-biomimetic apatite deposition on titanium

    Directory of Open Access Journals (Sweden)

    Saita M

    2016-01-01

    Full Text Available Makiko Saita,1 Takayuki Ikeda,1,2 Masahiro Yamada,1,3 Katsuhiko Kimoto,4 Masaichi Chang-Il Lee,5 Takahiro Ogawa1 1Division of Advanced Prosthodontics, Weintraub Center for Reconstructive Biotechnology, UCLA School of Dentistry, Los Angeles, CA, USA; 2Department of Complete Denture Prosthodontics, Nihon University School of Dentistry, Yokosuka, Japan; 3Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Miyagi, Japan; 4Department of Prosthodontics and Oral Rehabilitation, 5Yokosuka-Shonan Disaster Health Emergency Research Center and ESR Laboratories, Kanagawa Dental University Graduate School of Dentistry, Yokosuka, Japan Background: Although biomimetic apatite coating is a promising way to provide titanium with osteoconductivity, the efficiency and quality of deposition is often poor. Most titanium implants have microscale surface morphology, and an addition of nanoscale features while preserving the micromorphology may provide further biological benefit. Here, we examined the effect of ultraviolet (UV light treatment of titanium, or photofunctionalization, on the efficacy of biomimetic apatite deposition on titanium and its biological capability.Methods and results: Micro-roughed titanium disks were prepared by acid-etching with sulfuric acid. Micro-roughened disks with or without photofunctionalization (20-minute exposure to UV light were immersed in simulated body fluid (SBF for 1 or 5 days. Photofunctionalized titanium disks were superhydrophilic and did not form surface air bubbles when immersed in SBF, whereas non-photofunctionalized disks were hydrophobic and largely covered with air bubbles during immersion. An apatite-related signal was observed by X-ray diffraction on photofunctionalized titanium after 1 day of SBF immersion, which was equivalent to the one observed after 5 days of immersion of control titanium. Scanning electron microscopy revealed nodular apatite deposition

  4. Intermetallic communication in titanium(IV) ferrocenyldiketonates.

    Science.gov (United States)

    Dulatas, Lea T; Brown, Seth N; Ojomo, Edema; Noll, Bruce C; Cavo, Matthew J; Holt, Paul B; Wopperer, Matthew M

    2009-11-16

    A tetradentate bis(ferrocenyldiketonate) ligand, Fc(2)BobH(2), is prepared via Claisen condensation of acetylferrocene and 2,2'-biphenyldiacetyl chloride, and is metalated with titanium(IV) isopropoxide to give (Fc(2)Bob)Ti(O(i)Pr)(2) in good yield. The isopropoxide groups are replaced with di(4-nitrophenyl)phosphate groups on treatment with the corresponding acid, and with chlorides on treatment with trimethylsilyl chloride. Metathesis with catechol leads to the bis(o-hydroxyphenoxide) complex rather than the chelating catecholate complex. Hydrolysis selectively gives the mu-oxo trimer (Delta,Delta,Delta)/(Lambda,Lambda,Lambda)-{(Fc(2)Bob)Ti(mu-O)}(3). The solid-state structures of the mu-oxo trimer and the bis(o-hydroxyphenoxide) complex show that the ferrocene substituents are oriented proximal to the biphenyl backbone rather than pointed out toward the exogenous groups. The complexes show dramatic changes in color depending on the bound anions, ranging from the red isopropoxide (lambda(max) = 489 nm) to the green bis(di(4-nitrophenyl)phosphate) (lambda(max) = 653 nm). The oxidation potentials of the ferrocenes show modest shifts based on the titanium environment, but the redox potentials of the two ferrocenes are never separated by more than 60 mV. These results and those of density-functional theory (DFT) calculations indicate that the titanium interacts principally with the lowest unoccupied molecular orbital (LUMO) of the ferrocenyldiketonate and very little with its highest occupied molecular orbital (HOMO).

  5. Recent Advances in the Hot Working of Titanium Alloys

    Institute of Scientific and Technical Information of China (English)

    DANG Xiao-ling

    2012-01-01

    In this paper, recent advances in titanium alloy processing are reviewed. The casting, superplastic forming, friction stir welding and thermohydrogen processing of titanium alloys are developed. The great cost saving results from using casting comparing with the conventional machining for rings. The superplastic forming of titanium alloys is a feasible manufacturing technology for civil and military aircraft. The friction stir welding leds to the production of fully-formed, high quality friction stirwelds. In thermohydrogen processing, the high diffusivity of hydrogen in titanium is firstly used to add hydrogen to titanium alloys by controlled diffusion from a hydrogen environment , after thermohydrogen processing, to remove it by a controlled vacuum anneal so as to improve processing and mechanical properties.

  6. Local Heating with Lithographically Fabricated Plasmonic Titanium Nitride Nanoparticles

    DEFF Research Database (Denmark)

    Guler, Urcan; Ndukaife, Justus C.; Naik, Gururaj V.;

    2013-01-01

    Titanium nitride is considered a promising alternative plasmonic material and is known to exhibit localized surface plasmon resonances within the near-infrared biological transparency window. Here, local heating efficiencies of disk-shaped nanoparticles made of titanium nitride and gold are compa......Titanium nitride is considered a promising alternative plasmonic material and is known to exhibit localized surface plasmon resonances within the near-infrared biological transparency window. Here, local heating efficiencies of disk-shaped nanoparticles made of titanium nitride and gold...... are compared in the visible and near-infrared regions numerically and experimentally with samples fabricated using e-beam lithography. Results show that plasmonic titanium nitride nanodisks are efficient local heat sources and outperform gold nanodisks in the biological transparency window, dispensing the need...... for complex particle geometries....

  7. Growth of anatase titanium dioxide nanotubes via anodization

    Directory of Open Access Journals (Sweden)

    Ed Adrian Dilla

    2012-06-01

    Full Text Available In this work, titanium dioxide nanotubes were grown via anodization of sputtered titanium thin films using different anodization parameters in order to formulate a method of producing long anatase titanium dioxide nanotubes intended for solar cell applications. The morphological features of the nanotubes grown via anodization were explored using a Philips XL30 Field Emission Scanning Electron Microscope. Furthermore, the grown nanotubes were also subjected to X-ray diffraction and Raman spectroscopy in order to investigate the effect of the predominant crystal orientation of the parent titanium thin film on the crystal phase of the nanotubes. After optimizing the anodization parameters, nanotubes with anatase TiO2 crystal phase and tube length more than 2 microns was produced from parent titanium thin films with predominant Ti(010 crystal orientation and using ammonium fluoride in ethylene glycol as an electrolyte with a working voltage equal to 60V during 1-hour anodization runs.

  8. Effect of chemical polishing in titanium materials for low outgassing

    Science.gov (United States)

    Ishizawa, K.; Kurisu, H.; Yamamoto, S.; Nomura, T.; Murashige, N.

    2008-03-01

    A chemical polishing using a nitric acid solution was found to be the most suitable for the titanium materials. 1.8 nm of small surface roughness was observed in a microscopic range in 1 μm square, and 7 nm of a thin oxide layer was shown to exist for the chemically polished titanium. The surface processing for the titanium was developed combining the chemical polishing and the precision cleaning. The chemically polished pure titanium of JIS grade 2 showed extremely low outgassing rate below 10-12 Pams-1 after baking process, which is two orders of magnitude smaller than that for standard vacuum materials under the same baking condition. Outgassing rates of the titanium is about 1/5 of that for a stainless steel without baking process.

  9. Effect of chemical polishing in titanium materials for low outgassing

    Energy Technology Data Exchange (ETDEWEB)

    Ishizawa, K; Kurisu, H; Yamamoto, S [Graduate School of Science and Engineering, Yamaguchi University, Ube, Yamaguchi 755-8611 (Japan); Nomura, T; Murashige, N [CT division San-ai Plant Industries, Ltd, Kawasaki, Kanagawa 210-0821 (Japan)], E-mail: kishizawa@san-ai-oil.co.jp

    2008-03-01

    A chemical polishing using a nitric acid solution was found to be the most suitable for the titanium materials. 1.8 nm of small surface roughness was observed in a microscopic range in 1 {mu}m square, and 7 nm of a thin oxide layer was shown to exist for the chemically polished titanium. The surface processing for the titanium was developed combining the chemical polishing and the precision cleaning. The chemically polished pure titanium of JIS grade 2 showed extremely low outgassing rate below 10{sup -12} Pams{sup -1} after baking process, which is two orders of magnitude smaller than that for standard vacuum materials under the same baking condition. Outgassing rates of the titanium is about 1/5 of that for a stainless steel without baking process.

  10. Internal adaptation of cast titanium crowns

    Directory of Open Access Journals (Sweden)

    Sicknan Soares da Rocha

    2007-08-01

    Full Text Available As the adaptation of titanium crowns obtained by Rematitan Plus investment, specific for titanium, is not recognized to be suitable, this study evaluated the effect of the concentration of the specific liquid and the temperature of the mold of investments on the internal misfit of crowns cast on commercially pure titanium. Individual dies of epoxy resin were obtained, representing teeth prepared for full-crown restoration with a 6-degree axial surface convergence angle and shoulder (1.0 mm. For the waxing of each crown, a ring-shaped stainless steel matrix (8.0mm internal diameter; 7.5 mm height was adapted above the individual dies of epoxy resin. The Rematian Plus investment was mixed according to the manufacturer's instructions using two different concentrations of the specific liquid: 100%, 75%. Casting was performed in a Discovery Plasma Ar-arc vacuum-pressure casting machine with molds at temperatures of 430ºC, 515ºC and 600ºC. The crowns were cleaned individually in a solution (1% HF + 13% HNO3 for 10 min using a ultrasonic cleaner, with no internal adaptations, and luted with zinc phosphate cement under a 5 kg static load. The crown and die assemblies were embedded in resin and sectioned longitudinally. The area occupied by cement was observed using stereoscopic lens (10X and measured by the Leica Qwin image analysis system (mm². The data for each experimental condition (n=8 were analyzed by Kruskal-Wallis non-parametric test (á=0.05. The results showed that liquid dilution and the increase in mold temperature did not significantly influence the levels of internal fit of the cast titanium crowns. The lowest means (±SD of internal misfit were obtained for the 430ºC/100%: (7.25 mm² ±1.59 and 600ºC/100% (8.8 mm² ±2.25 groups, which presented statistically similar levels of internal misfit.

  11. Titanium carbide coatings for aerospace ball bearings

    Science.gov (United States)

    Boving, Hans J.; Haenni, Werner; Hintermann, HANS-E.

    1988-01-01

    In conventional ball bearings, steel to steel contacts between the balls and the raceways are at the origin of microwelds which lead to material transfer, surface roughening, lubricant breakdown, and finally to a loss in the bearing performances. To minimize the microwelding tendencies of the contacting partners it is necessary to modify their surface materials; the solid to solid collisions themselves are difficult to avoid. The use of titanium carbide coated steel balls can bring spectacular improvements in the performances and lifetimes of both oil-grease lubricated and oil-grease free bearings in a series of severe applications.

  12. Laser Welding of TC-1 Titanium Alloy

    Institute of Scientific and Technical Information of China (English)

    Hanbin DU; Lunji HU; Xiyuan HU; Jianhua LIU

    2003-01-01

    The technology of CO2 laser welding and joint properties of titanium alloy were investigated. The problem of moltenpool protection was resolved by designing a shielding trailer and a special clamp. Joints with silvery appearance wereobtained, which have no pore and crack. In addition, the welding speed could reach 3 m/min for the plate of 1.5 mmthickness being penetrated. The reason of the porosity formation in partial penetration joints is that the keyholescan be easily cut apart in the radial direction, which makes the gas enclosed in the molten pool. The surface oxideof specimens can not affect the porosity formation in welds directly.

  13. ZIRCONIUM-TITANIUM-BERYLLIUM BRAZING ALLOY

    Science.gov (United States)

    Gilliland, R.G.; Patriarca, P.; Slaughter, G.M.; Williams, L.C.

    1962-06-12

    A new and improved ternary alloy is described which is of particular utility in braze-bonding parts made of a refractory metal selected from Group IV, V, and VI of the periodic table and alloys containing said metal as a predominating alloying ingredient. The brazing alloy contains, by weight, 40 to 50 per cent zirconium, 40 to 50 per cent titanium, and the balance beryllium in amounts ranging from 1 to 20 per cent, said alloy having a melting point in the range 950 to 1400 deg C. (AEC)

  14. Characterization of cellular titanium for biomedical applications

    Science.gov (United States)

    Hrabe, Nikolas Wilson

    By controlling structural features (relative density, pore size, strut size) of cellular titanium (also known as porous titanium), the mechanical properties can be optimized to reduce the effects of stress shielding currently observed in load-bearing bone replacement implants. Thermal gravimetric analysis of a sacrificial scaffold system lead to important processing modifications in an attempt to meet chemistry requirements for surgical grade titanium not met in previous work. Despite these modifications chemistry did not meet requirements for carbon, nitrogen, or oxygen. Commercially pure titanium (CPTi) porous structures were made over a range of relative densities using laser engineered net shaping (LENS). From monotonic compression tests, yield strength and elastic modulus in the range of bone were achieved but did not scale with relative density as predicted by the Gibson-Ashby analytical model. Compression-compression fatigue resistance was high, as no failures were observed for test stresses up to 133% yield strength, which is thought to be influenced by the dense exterior shell of the samples. Structures were also fabricated over a range of relative densities using selective electron beam melting (SEBM or EBM), and structural, mechanical, and in-vitro properties were measured for three materials (as-built Ti-6A1-4V, Ti-6A1-4V after hot isostatic pressing (HIPing), and as-built CPTi). For structures of all three materials, yield strength and elastic modulus was within the range for bone. Numerical modeling results suggested cell shape and sintered particles on strut surfaces affect the scaling of elastic modulus with relative density and lead to the observed difference from the Gibson-Ashby model. Normalized fatigue strengths at 106 cycles ranged from 0.150.25 for as-built Ti-6A1-4V structures, which is lower than expected. Results for HIPed Ti-6A1-4V structures and CPTi structures suggest that stress concentrations from closed porosity within struts as well

  15. Laser-TIG Welding of Titanium Alloys

    Science.gov (United States)

    Turichin, G.; Tsibulsky, I.; Somonov, V.; Kuznetsov, M.; Akhmetov, A.

    2016-08-01

    The article presents the results of investigation the technological opportunity of laser-TIG welding of titanium alloys. The experimental stand for implementation of process with the capability to feed a filler wire was made. The research of the nature of transfer the filler wire into the welding pool has been demonstrated. The influence of distance between the electrode and the surface of the welded plates on the stability of the arc was shown. The relationship between welding velocity, the position of focal plane of the laser beam and the stability of penetration of plates was determined.

  16. Magnetic susceptibility of tetragonal titanium dioxide

    Science.gov (United States)

    Senftle, F.E.; Pankey, T.; Grant, F.A.

    1960-01-01

    Careful measurements have been made of the magnetic susceptibility of the rutile and anatase crystalline forms of titanium dioxide. The magnetic susceptibility of a single crystal of high-purity rutile was found to be (0.067??0.0015)??10-6 emu per gram, and was temperature-independent from 55??to 372??K. Difficulty was encountered in obtaining a good value of the magnetic susceptibility of anatase because of impurities. However, a value of 0.02??10-6 emu per gram was obtained as a maximum value for anatase powder. A discussion is given for the different values obtained for anatase and rutile. ?? 1960 The American Physical Society.

  17. RESEARCH INVESTIGATIONS OF WATER PURIFICATION PROCESS WITH PHOTOCATALYST BASED ON POROUS TITANIUM WITH NANOPARTICLES OF TITANIUM DIOXIDE

    Directory of Open Access Journals (Sweden)

    L. Pilinevich

    2013-01-01

    Full Text Available The paper presents results of the investigations on the water purification process with the help of photocatalysis using the photocatalyst which is developed on the basis of porous titanium with the layer of nanoparticle layer of titanium dioxide and an experimental plant. The investigations results have shown high efficiency of the developed photocatalytic materials and a water purification plants

  18. Application of sintered titanium alloys to metal denture bases: a study of titanium powder sheets for complete denture base.

    Science.gov (United States)

    Doi, H; Harrori, M; Hasegawa, K; Yoshinari, M; Kawada, E; Oda, Y

    2001-02-01

    The purpose of this study was the fabrication of titanium powder sheets to enable the application of sintered titanium alloys as metal denture bases. The effects of titanium particle shape and size, binder content, and plasticizer content on the surface smoothness, tensile strength and elongation of titanium powder sheets was investigated. To select a suitable ratio of powdered metal contents for application as a metal denture base, the effects of aluminum content in Ti sheets and various other powder metal contents in Ti-Al sheets on the density, sintering shrinkage, and bending strength were evaluated. Based on the results of the above experiments, we developed a mixed powder sheet composed of 83Ti-7Al-10Cr with TA45 titanium powder (atomized, -45 microm), and 8 mass% binder content. This titanium alloy sheet had good formability and ductility. Its sintered titanium alloy had a density of 3.2 g/cm3, sintering shrinkage of 3.8%, and bending strength of 403 MPa. The titanium alloy sheet is clinically acceptable for fabricating denture bases.

  19. Equilibrium between titanium ions and high-purity titanium electrorefining in a NaCl-KCl melt

    Institute of Scientific and Technical Information of China (English)

    Jian-xun Song; Qiu-yu Wang; Guo-jing Hu; Xiao-bo Zhu; Shu-qiang Jiao; Hong-min Zhu

    2014-01-01

    TiClx (x=2.17) was prepared by using titanium sponge to reduce the concentration of TiCl4 in a NaCl−KCl melt under negative pressure. The as-prepared NaCl−KCl−TiClx melt was employed as the electrolyte, and two parallel crude titanium plates and one high-purity titanium plate were used as the anode and cathode, respectively. A series of electrochemical tests were performed to investigate the influence of electrolytic parameters on the current efficiency and quality of cathodic products. The results indicated that the quality of cathodic prod-ucts was related to the current efficiency, which is significantly dependent on the current density and the initial concentration of titanium ions. The significance of this study is the attainment of high-purity titanium with a low oxygen content of 30 × 10−6.

  20. High Frequency Discharge Plasma Induced Grafting of Polystyrene onto Titanium Dioxide Powder

    Institute of Scientific and Technical Information of China (English)

    ZHONG Shaofeng; OU Qiongrong; MENG Yuedong

    2007-01-01

    Grafting of polystyrene (PS) onto titanium dioxide powder was investigated. The graft polymerization reaction was induced by high frequency discharge produced N2 plasma treatment of the surfaces of titanium dioxide. IR , XPS and TGA results show that PS was grafted on the titanium dioxide powder. And the crystal structure of the titanium dioxide powder observed by XRD was unchanged after plasma treatment.

  1. Nickel-titanium alloys: a systematic review

    Directory of Open Access Journals (Sweden)

    Marcelo do Amaral Ferreira

    2012-06-01

    Full Text Available OBJECTIVE: A systematic review on nickel-titanium wires was performed. The strategy was focused on Entrez-PubMed-OLDMEDLINE, Scopus and BioMed Central from 1963 to 2008. METHODS: Papers in English and French describing the behavior of these wires and laboratorial methods to identify crystalline transformation were considered. A total of 29 papers were selected. RESULTS: Nickel-titanium wires show exceptional features in terms of elasticity and shape memory effects. However, clinical applications request a deeper knowledge of these properties in order to allow the professional to use them in a rational manner. In addition, the necessary information regarding each alloy often does not correspond to the information given by the manufacturer. Many alloys called "superelastic" do not present this effect; they just behave as less stiff alloys, with a larger springback if compared to the stainless steel wires. CONCLUSIONS: Laboratory tests are the only means to observe the real behavior of these materials, including temperature transition range (TTR and applied tensions. However, it is also possible to determine in which TTR these alloys change the crystalline structure.

  2. Optimal welding of beta titanium orthodontic wires.

    Science.gov (United States)

    Nelson, K R; Burstone, C J; Goldberg, A J

    1987-09-01

    Today the orthodontist is confronted by an array of new orthodontic wire materials that, when applied to appliance design, can vastly increase the flexibility and versatility of therapy. Welded joints, especially for the newer titanium alloy wires, provide a means to extend the useful applications of these materials. The purpose of this study was to determine the optimum settings for electrical resistance welding of various configurations of titanium-molybdenum (TMA) wires. Specimens were of a t-joint configuration and were mechanically tested in torsion to simulate the failure mode most often observed in clinical practice. Variables included wire size, wire orientation, and welding voltage. Results indicated that excellent welds can be obtained with very little loss of strength and ductility in the area of the weld joint. Torsional loads at failure were at least 90% of the unwelded base material. Although a wide range of voltage settings resulted in high-strength welds, typically a narrow range of voltages yielded optimal ductility.

  3. Hydrogenation-induced microstructure changes in titanium

    Energy Technology Data Exchange (ETDEWEB)

    Laptev, R., E-mail: laptevrs@tpu.ru; Lider, A., E-mail: lider@tpu.ru; Bordulev, Yu., E-mail: bus@tpu.ru; Kudiiarov, V., E-mail: kudiyarov@tpu.ru; Garanin, G., E-mail: garaningv@tpu.ru

    2015-10-05

    Highlights: • Hydrogen induced microstructure changes in Ti studied by PL and DB spectroscopies. • Vacancies and vacancy clusters formed at concentration from 1.31 to 2.27 at.%. • Cluster-hydrogen and vacancy-hydrogen complexes formed at concentration up to 32 at.%. - Abstract: Microstructure changes of commercially pure titanium in a wide range of hydrogen concentrations from 0.8 at.% to 32.0 at.% were studied by means of positron lifetime spectroscopy and Doppler broadening spectroscopy. We have obtained new experimental data on the evolution of positron annihilation parameters τ{sub f}, τ{sub d} and their corresponding intensities I{sub f}, I{sub d,} as well as relative changes of parameters S/S{sub 0} and W/W{sub 0} depending on the hydrogen concentration in commercially pure titanium after gas-phase hydrogenation at 873 K. Results suggest that the hydrogenation of Ti samples up to concentrations of 1.31–2.27 at.% and subsequent cooling to a room temperature leads to the formation of vacancies and vacancy clusters. Further increase of the hydrogen concentration up to 32.0 at.% leads to the interaction of hydrogen with these defects and the formation of “cluster-hydrogen” and “vacancy-hydrogen” complexes.

  4. Sintering of titanium alloy by powder metallurgy

    Energy Technology Data Exchange (ETDEWEB)

    Cosme, C.R.M. [Universidade de Brasilia (UnB), DF (Brazil); Henriques, V.A.R.; Cairo, C.A.A.; Taddei, E.B. [Centro Tecnico Aeroespacial (CTA), Sao Jose dos Campos, SP (Brazil)

    2009-07-01

    Full text: Titanium alloys are suitable for biomaterial applications, considering its biocompatibility and low elastic modulus compared to steel. Bone resorption in this case can be reduced by load sharing between the implant and natural bone.Starting powders were obtained by hydride method, carried out under positive hydrogen pressure at 500 deg C for titanium and 800 deg C for Nb, Zr and Ta powders. After reaching the nominal temperature, the material was held for 3h, with subsequent cooling to room temperature and milling of the friable hydride. Samples were produce by mixing of initial metallic powders followed by and cold isostatic pressing. Subsequent densification by sintering was performed at temperature range between 900 and 1700 deg C. Characterization was carried out with scanning electron microscopy, X-ray diffractometry and microhardness measurements. Microstructural examinations revealed higher amount of &⧣946;-phase for higher sintering temperature and dissolution of Ta and NB particles. In vitro tests revealed low cytotoxicity of sintered samples. (author)

  5. Titanium aluminides production by powder metallurgy

    Energy Technology Data Exchange (ETDEWEB)

    Henriques, V.A.R. [Centro Tecnico Aeroespacial (CTA), Sao Jose dos Campos, SP (Brazil); Silva, C.R.M. [Universidade de Brasilia (UnB), Brasilia, DF (Brazil); Goncalves, F.F.R. [Instituto Tecnologico de Aeronautica (ITA), Sao Jose dos Campos, SP (Brazil)

    2009-07-01

    Full text: The aim of this work is to analyze the gamma-titanium-aluminideo alloys obtained by powder metallurgy. Theses alloys have high temperature resistance (until 850 deg C) for a long time with utilization in aircraft with high speed and can be applied in automotive engines valves or turbocharger rotors. This paper shows the microstructures results of Ti-48Al-2Cr-2Nb obtained by pressureless sintering and hot uniaxial pressing. The powders were mixed for one hour and compacted using cold isostatic pressing (300 MPa). The specimens were processed by sintering in vacuum between 900-1300 deg C and by hot uniaxial pressing (20 MPa) in argon atmosphere between 900-1200 deg C, for 2h. The alloys were characterized by XRD (X-ray diffraction), SEM (Scanning Electron Microscopy), EDS (Energy Dispersive Spectroscopy) and Vickers microhardness measurements. The results evidence that hot uniaxial pressing route has the tendency to obtain gamma-TiAl and alpha 2-Ti3Al intermetallics ( in a lamellar distribution) than the pressureless sintering route, mainly because of the high niobium diffusion in the titanium matrix. (author)

  6. Molecular and physiological responses to titanium dioxide ...

    Science.gov (United States)

    - Changes in tissue transcriptomes and productivity of Arabidopsis thaliana were investigated during exposure of plants to two widely-used engineered metal oxide nanoparticles, titanium dioxide (nano-titanium) and cerium dioxide (nano-cerium). Microarray analyses confirmed that exposure to either nanoparticle altered the transcriptomes of rosette leaves and roots, with comparatively larger numbers of differentially expressed genes (DEGs) found under nano-titania exposure. Nano-titania induced more DEGs in rosette leaves, whereas roots had more DEGs under nano-ceria exposure. MapMan analyses indicated that while nano-titania up-regulated overall and secondary metabolism in both tissues, metabolic processes under nano-ceria remained mostly unchanged. Gene enrichment analysis indicated that both nanoparticles mainly enriched ontology groups such as responses to stress (abiotic and biotic), and defense responses (pathogens), and responses to endogenous stimuli (hormones). Nano-titania specifically induced genes associated with photosynthesis, whereas nano-ceria induced expression of genes related to activating transcription factors, most notably those belonging to the ethylene responsive element binding protein family. Interestingly, there were also increased numbers of rosette leaves and plant biomass under nano-ceria exposure, but not under nano-titania. Other transcriptomic responses did not clearly relate to responses observed at the organism level. This may b

  7. Nanomaterial Case Studies: Nanoscale Titanium Dioxide in ...

    Science.gov (United States)

    EPA announced the availability of the final report, Nanomaterial Case Studies: Nanoscale Titanium Dioxide in Water Treatment and in Topical Sunscreen. This report is a starting point to determine what is known and what needs to be known about selected nanomaterials as part of a process to identify and prioritize research to inform future assessments of the potential ecological and health implications of these materials. Two specific applications of nanoscale titanium dioxide (nano-TiO2) are considered: (1) as an agent for removing arsenic from drinking water; and (2) as an active ingredient in topical sunscreen. These case studies are organized around a comprehensive environmental assessment (CEA) framework that combines a product life cycle perspective with the risk assessment paradigm. They are intended to help identify what may need to be known in order to conduct a comprehensive environmental assessment of the potential risks related to nano-TiO2. These “case studies” do not represent completed or even preliminary assessments, nor are they intended to serve as a basis for risk management decisions in the near term on these specific uses of nano TiO2. Rather, the intent is to use this document in developing the scientific and technical information needed for future assessment efforts.

  8. Outgassing Properties of Chemically Polished Titanium Materials

    Science.gov (United States)

    Kurisu, Hiroki; Kimoto, Gou; Fujii, Hiroaki; Tanaka, Kazuhiko; Yamamoto, Setsuo; Matsuura, Mitsuru; Ishizawa, Katsunobu; Nomura, Takeru; Murashige, Nobuyuki

    We developed a chemical polishing (CP) for titanium materials applicable to ultrahigh vacuum (UHV) and extremely high vacuum (XHV) systems. The surface roughness, Ra, of the chemically polished titanium is obtained to be 25 nm by the atomic force microscopy measurement. This value is smaller than those of the base metal (BM) and the buff-polished (BP) samples. The thickness of the surface oxide layer of CP sample is estimated to be 7 nm by the cross section of transmission electron micrograph. Amount of desorption gas of CP sample obtained by the thermal desorption measurement is smaller than those of BM and BP sample, and is the same as that of the mechanochemically polished (MCP) sample. The outgassing rate of CP sample after baking at 150°C×20 h is obtained to be 7×10-13 Pa•m•s-1. This value is lower than that of standard vacuum materials by two orders of magnitude after the ordinary baking.

  9. Improve seawater cooling with titanium finned tubes

    Energy Technology Data Exchange (ETDEWEB)

    O' Donnell J. (High Performance Tube, Inc., Warren, NJ (United States))

    1992-10-01

    Seawater offers an endless supply of cooling water for these coastal processing facilities. But users must address seawater's corrosive nature in selecting construction materials for heat exchangers. Copper-nickel or carbon steel tubing fails continually under seawater service. This paper reports that titanium tubes, once thought to be too expensive a material for heat exchanger tubing, offer a unique combination of high material strength, excellent resistance to corrosion, and endurance to erosion by seawater. Titanium's superior physical properties in combination with enhanced surface area of low finned tubing perform the same heat duty with half the lineal footage of traditional heat exchanger tubes. High density low finned tubes multiply heat transfer capacity by a factor of two compared to plain tube. The technology applies in retrofit and original equipment manufacture (OEM) situations. It works best when the ratio of heat transfer coefficients is 2:1 or higher between the seawater coolant and shellside flow being cooled.

  10. Tissue response to implanted ceramic-coated titanium alloys in rats.

    Science.gov (United States)

    Satomi, K; Akagawa, Y; Nikai, H; Tsuru, H

    1988-07-01

    In order to assess the tissue compatibility of the hybrid materials for the dental implant (hydroxyapatite, titanium oxide and titanium nitride coated titanium alloys), tissue response to these materials implanted in the rat subcutaneous tissue was histologically examined. Initial inflammatory response was less evident in titanium oxide coated and non-coated titanium alloys. All materials were encapsulated by thin fibrous connective tissues. The membrane thickness of hydroxyapatite coated titanium alloy was significantly higher than that of titanium nitride coated one. These results suggest that all materials possess favourable tissue compatibility and may encourage clinical use as the dental implant.

  11. Effect of cathodic polarization on coating doxycycline on titanium surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Geißler, Sebastian; Tiainen, Hanna; Haugen, Håvard J., E-mail: h.j.haugen@odont.uio.no

    2016-06-01

    Cathodic polarization has been reported to enhance the ability of titanium based implant materials to interact with biomolecules by forming titanium hydride at the outermost surface layer. Although this hydride layer has recently been suggested to allow the immobilization of the broad spectrum antibiotic doxycycline on titanium surfaces, the involvement of hydride in binding the biomolecule onto titanium remains poorly understood. To gain better understanding of the influence this immobilization process has on titanium surfaces, mirror-polished commercially pure titanium surfaces were cathodically polarized in the presence of doxycycline and the modified surfaces were thoroughly characterized using atomic force microscopy, electron microscopy, secondary ion mass spectrometry, and angle-resolved X-ray spectroscopy. We demonstrated that no hydride was created during the polarization process. Doxycycline was found to be attached to an oxide layer that was modified during the electrochemical process. A bacterial assay using bioluminescent Staphylococcus epidermidis Xen43 showed the ability of the coating to reduce bacterial colonization and planktonic bacterial growth. - Highlights: • Titanium hydride was found not to be involved in immobilization of doxycycline. • Doxycycline coating was strongly bound to a modified surface oxide layer. • Effect of coatings tested using a dynamic bacteria assay based on bioluminescence. • Topmost layer of adsorbed doxycycline was shown to have strong antibacterial effect.

  12. Experimental Technique of Titanium Fire in Aero-engine

    Directory of Open Access Journals (Sweden)

    MI Guangbao

    2016-06-01

    Full Text Available Titanium fire is the typical catastrophic fault in the aero-engine. Aiming at the urgent demand for experimental technique of titanium fire from advanced high thrust-weight ratio aero-engine, the combustion technology and theory of titanium alloy based on friction oxygen concentration method (FOC were systematically studied. The evaluation method of fireproof property and the friction ignition model were built, and the fireproof mechanism was illustrated. By generalizing recent progress in experimental technique of titanium fire from three levels, including evolutionary rule, mechanism and prevention and control technology, the ideas and directions of experimental technique associated with the application research of titanium fire in the future were proposed, namely overall evaluation of fireproof property close to air flow environment of the aero-engine, prediction model of fireproof property and experimental verification of fireproof technique under the air flow environment of aero-engine. It is necessary to establish the prevention system of titanium fire in aero-engine, which contributes to the realization of "full titanium" in compressor and to the increase of high thrust-weight ratio.

  13. Temporarily alloying titanium to facilitate friction stir welding

    Energy Technology Data Exchange (ETDEWEB)

    Hovanski, Yuri [Washington State Univ., Pullman, WA (United States)

    2009-05-01

    While historically hydrogen has been considered an impurity in titanium, when used as a temporary alloying agent it promotes beneficial changes to material properties that increase the hot-workability of the metal. This technique known as thermohydrogen processing was used to temporarily alloy hydrogen with commercially pure titanium sheet as a means of facilitating the friction stir welding process. Specific alloying parameters were developed to increase the overall hydrogen content of the titanium sheet ranging from commercially pure to 30 atomic percent. Each sheet was evaluated to determine the effect of the hydrogen content on process loads and tool deformation during the plunge phase of the friction stir welding process. Two materials, H-13 tool steel and pure tungsten, were used to fabricate friction stir welding tools that were plunged into each of the thermohydrogen processed titanium sheets. Tool wear was characterized and variations in machine loads were quantified for each tool material and weld metal combination. Thermohydrogen processing was shown to beneficially lower plunge forces and stabilize machine torques at specific hydrogen concentrations. The resulting effects of hydrogen addition to titanium metal undergoing the friction stir welding process are compared with modifications in titanium properties documented in modern literature. Such comparative analysis is used to explain the variance in resulting process loads as a function of the initial hydrogen concentration of the titanium.

  14. Optimisation of Sintering Factors of Titanium Foams Using Taguchi Method

    Directory of Open Access Journals (Sweden)

    S. Ahmad

    2010-06-01

    Full Text Available Metal foams have the potential to be used in the production of bipolar plates in Polymer Electron Membrane Fuel Cells (PEMFC. In this paper, pure titanium was used to prepare titanium foam using the slurry method. The electrical conductivity is the most important parameter to be considered in the production of good bipolar plates. To achieve a high conductivity of the titanium foam, the effects of various parameters including temperature, time profile and composition have to be characterised and optimised. This paper reports the use of the Taguchi method in optimising the processing parameters of pure titanium foams. The effects of four sintering factors, namely, composition, sintering temperature, heating rate and soaking time on the electrical conductivity has been studied. The titanium slurry was prepared by mixing titanium alloy powder, polyethylene glycol (PEG, methylcellulose and water. Polyurethane (PU foams were then impregnated into the slurry and later dried at room temperature. These were next sintered in a high temperature vacuum furnace. The various factors were assigned to an L9 orthogonal array. From the Analysis of Variance (ANOVA, the composition of titanium powder has the highest percentage of contribution (24.51 to the electrical conductivity followed by the heating rate (10.29. The optimum electrical conductivity was found to be 1336.227 ± 240.61 S/cm-1 for this titanium foam. It was achieved with a 70% composition of titanium, sintering temperature of 1200oC, a heating rate of 0.5oC/min and 2 hours soaking time. Confirmatory experiments have produced results that lay within the 90% confidence interval.

  15. Surface Functionalization of Orthopedic Titanium Implants with Bone Sialoprotein.

    Directory of Open Access Journals (Sweden)

    Andreas Baranowski

    Full Text Available Orthopedic implant failure due to aseptic loosening and mechanical instability remains a major problem in total joint replacement. Improving osseointegration at the bone-implant interface may reduce micromotion and loosening. Bone sialoprotein (BSP has been shown to enhance bone formation when coated onto titanium femoral implants and in rat calvarial defect models. However, the most appropriate method of BSP coating, the necessary level of BSP coating, and the effect of BSP coating on cell behavior remain largely unknown. In this study, BSP was covalently coupled to titanium surfaces via an aminosilane linker (APTES, and its properties were compared to BSP applied to titanium via physisorption and untreated titanium. Cell functions were examined using primary human osteoblasts (hOBs and L929 mouse fibroblasts. Gene expression of specific bone turnover markers at the RNA level was detected at different intervals. Cell adhesion to titanium surfaces treated with BSP via physisorption was not significantly different from that of untreated titanium at any time point, whereas BSP application via covalent coupling caused reduced cell adhesion during the first few hours in culture. Cell migration was increased on titanium disks that were treated with higher concentrations of BSP solution, independent of the coating method. During the early phases of hOB proliferation, a suppressive effect of BSP was observed independent of its concentration, particularly when BSP was applied to the titanium surface via physisorption. Although alkaline phosphatase activity was reduced in the BSP-coated titanium groups after 4 days in culture, increased calcium deposition was observed after 21 days. In particular, the gene expression level of RUNX2 was upregulated by BSP. The increase in calcium deposition and the stimulation of cell differentiation induced by BSP highlight its potential as a surface modifier that could enhance the osseointegration of orthopedic implants

  16. Improved adherence of sputtered titanium carbide coatings on nickel- and titanium-base alloys

    Science.gov (United States)

    Wheeler, D. R.; Brainard, W. A.

    1979-01-01

    Rene 41 and Ti-6Al-4V alloys were radio frequency sputter coated with titanium carbide by several techniques in order to determine the most effective. Coatings were evaluated in pin-on-disk tests. Surface analysis by X-ray photoelectron spectroscopy was used to relate adherence to interfacial chemistry. For Rene 41, good coating adherence was obtained when a small amount of acetylene was added to the sputtering plasma. The acetylene carburized the alloy surface and resulted in better bonding to the TiC coating. For Ti-6Al-4V, the best adherence and wear protection was obtained when a pure titanium interlayer was used between the coating and the alloy. The interlayer is thought to prevent the formation of a brittle, fracture-prone, aluminum oxide layer.

  17. Laser beam welding of titanium nitride coated titanium using pulse-shaping

    Directory of Open Access Journals (Sweden)

    Milton Sergio Fernandes de Lima

    2005-09-01

    Full Text Available A new welding method which allows the assembly of two titanium nitride coated titanium parts is proposed. The welding procedure utilizes the possibility for pulse-shaping in order to change the energy distribution profile during the laser pulse. The pulse-shaping is composed of three elements: a a short high power pulse for partial ablation at the surface; b a long pulse for thermal penetration; and c a quenching slope for enhanced weldability. The combination of these three elements produces crack-free welds. The weld microstructure is changed in comparison to normal welding, i.e. with a rectangular pulse, as the nitrogen and the microhardness are more homogenously distributed in the weld under pulse-shaping conditions. This laser pulse dissolves the TiN layer and allows nitrogen to diffuse into the melt pool, also contributing to an enhanced weldability by providing suitable thermal conditions.

  18. Engineering Titanium for Improved Biological Response

    Energy Technology Data Exchange (ETDEWEB)

    Orme, C; Bearinger, J; Dimasi, E; Gilbert, J

    2002-01-23

    The human body and its aggressive environment challenge the survival of implanted foreign materials. Formidable biocompatibility issues arise from biological, chemical, electrical, and tribological origins. The body's electrolytic solution provides the first point of contact with any kind of implant, and is responsible for transport, healing, integration, or attack. Therefore, determining how to successfully control the integration of a biomaterial should begin with an analysis of the early interfacial dynamics involved. setting, a complicated feedback system of solution chemistry, pH, ions, and solubility exists. The introduction of a fixation device instantly confounds this system. The body is exposed to a range of voltages, and wear can bring about significant shifts in potentials across an implant. In the environment of a new implant the solution pH becomes acidic, ionic concentrations shift, cathodic currents can lead to corrosion, and oxygen levels can be depleted; all of these impact the ability of the implant to retain its protective oxide layer and to present a stable interface for the formation of a biolayer. Titanium has been used in orthopedic and maxilofacial surgery for many years due to its reputation as being biocompatible and its ability to osseointegrate. Osseointegration is defined as direct structural and functional connection between ordered, living bone, and the surface of a load carrying implant. Branemark discovered this phenomenon in the 60's while examining titanium juxtaposed to bone. The mechanism by which titanium and its passivating oxide encourage osseosynthetic activity remains unknown. However in general terms the oxide film serves two purposes: first to provide a kinetic barrier that prevents titanium from corroding and second to provide a substrate that allows the constituents of bone (calcium phosphate crystals, cells, proteins, and collagen) to bond to it. We believe that the electrochemical environment dictates the

  19. Superplastic Forming and Diffusion Bonding of Titanium Alloys

    Directory of Open Access Journals (Sweden)

    A. K. Ghosh

    1986-04-01

    Full Text Available New and advanced fabrication methods for titanium components are emerging today to replace age-old fabrication processes and reduce component cost. Superplastic forming and diffusion bonding are two such advanced fabrication technologies which when applied individually or in combination can provide significant cost and weight benefits and a rather broad manufacturing technology base. This paper briefly reviews the state of understanding of the science and technology of super plastic forming of titanium alloys, and their diffusion bonding capability. Emphasis has been placed on the metallurgy of superplastic flow in two phase titanium alloys, the microstructural and external factors which influence this behaviour.

  20. Titanium aluminide intermetallic alloys with improved wear resistance

    Energy Technology Data Exchange (ETDEWEB)

    Qu, Jun; Lin, Hua-Tay; Blau, Peter J.; Sikka, Vinod K.

    2014-07-08

    The invention is directed to a method for producing a titanium aluminide intermetallic alloy composition having an improved wear resistance, the method comprising heating a titanium aluminide intermetallic alloy material in an oxygen-containing environment at a temperature and for a time sufficient to produce a top oxide layer and underlying oxygen-diffused layer, followed by removal of the top oxide layer such that the oxygen-diffused layer is exposed. The invention is also directed to the resulting oxygen-diffused titanium aluminide intermetallic alloy, as well as mechanical components or devices containing the improved alloy composition.

  1. Titanium Iodies Mediated Intriguing Transformation of Organic Molecules

    Institute of Scientific and Technical Information of China (English)

    Makoto; SHIMIZU

    2007-01-01

    1 Results Titanium iodides have been found to be good reagents for iodination,reductive formation of enolates,pinacol coupling,and so on.Following new reactions will be discussed:(1) Iodination: Titanium(Ⅳ) iodide is a good iodination reagent for olefins and acetylenes.Simple olefins are iodotitanated with titanium (Ⅳ) iodide to give,after quenching with water,iodoalkanes in moderate to good yields.Phenylacetylene gives α-iodostyrene,whereas 2,2-diiodoalkanes are major products from 1-alkynes when they...

  2. Effects of titanium coating on property of diamond

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The titanium film was coated on the surface of diamond crystal in order to improve the chemical properties of diamond and the effect of titanium coating on the property of diamond was discussed. The anti-impacting strength, the oxidization process and the soakage property between vitrified bond and diamond were investigated. It is found that, when the titanium film is coated on the surface of diamond crystal, the soakage angle between vitrified bond and diamond decreases from 39.5° to 34.5° at 993 K, and the oxidization degree on the surface of diamonds is lowered greatly.

  3. Thermodynamic equilibrium diagram of the chlorine-titanium system

    Institute of Scientific and Technical Information of China (English)

    DU Ailing; GUO Xiaofei; ZHANG Heming; LIU Jiang

    2005-01-01

    The chemical and electrochemical equilibria of the chlorine-titanium system in the presence of gaseous phase were investigated. Many species, which consisted of chlorine and titanium, were considered. Various thermodynamic equilibria were calculated in the different pressures at different temperatures. The calculated results were shown as log p-1/T and E-T diagrams. These diagrams may be used as important tools for corrosion study and titanium production. The diagrams are also used to thermodynamically determine the existence areas of various species and so on.

  4. Investigations of Titanium Implants Covered with Hydroxyapatite Layer

    Directory of Open Access Journals (Sweden)

    Świeczko – Żurek B.

    2016-06-01

    Full Text Available To reduce unfavorable phenomena occurring after introducing an implant into human body various modifications of the surface are suggested. Such modifications may have significant impact on biocompatibility of metallic materials. The titanium and it's alloys are commonly used for joint and dental implants due to their high endurance, low plasticity modulus, good corrosion resistance as well as biocompatibility. Special attention should be given to titanium alloys containing zirconium, tantalum and niobium elements. These new generation alloys are used by worldwide engineering specialists. The experiments were performed with hydroxyapatite layer on titanium specimens with the use of electrophoresis method (different voltage and time.

  5. Colloidal Plasmonic Titanium Nitride Nanoparticles: Properties and Applications

    Directory of Open Access Journals (Sweden)

    Guler Urcan

    2015-01-01

    Full Text Available Optical properties of colloidal plasmonic titanium nitride nanoparticles are examined with an eye on their photothermal and photocatalytic applications via transmission electron microscopy and optical transmittance measurements. Single crystal titanium nitride cubic nanoparticles with an average size of 50 nm, which was found to be the optimum size for cellular uptake with gold nanoparticles [1], exhibit plasmon resonance in the biological transparency window and demonstrate a high absorption efficiency. A self-passivating native oxide at the surface of the nanoparticles provides an additional degree of freedom for surface functionalization. The titanium oxide shell surrounding the plasmonic core can create new opportunities for photocatalytic applications.

  6. Producing lower-cost titanium for automotive applications

    Science.gov (United States)

    Hartman, A. D.; Gerdemann, S. J.; Hansen, J. S.

    1998-09-01

    Although titanium has attractive properties that can improve the performance and economy of automobiles, at its current cost, it cannot compete with steel in most applications for which it is suited. It is readily apparent that titanium cannot be considered a viable mass-market automotive materials alternative as long as it is produced with the Kroll process. A look at existing and new technologies (as well as some that have been found lacking) in terms of applicability toward high-volume, low-cost titanium production for automotive applications indicates other options.

  7. Electrochemical characterization of cast titanium alloys.

    Science.gov (United States)

    Cai, Zhuo; Shafer, Ty; Watanabe, Ikuya; Nunn, Martha E; Okabe, Toru

    2003-01-01

    A reaction layer forms on cast titanium alloy surfaces due to the reaction of the molten metal with the investment. This surface layer may affect the corrosion of the alloy in the oral environment. The objective of this study was to characterize the in vitro corrosion behavior of cast titanium alloys. ASTM Grade 2 CP titanium, Ti-6Al-4V, Ti-6Al-7Nb and Ti-13Nb-13Zr alloys were cast into a MgO-based investment. Experiments were performed on castings (N=4) with three surface conditions: (A) as-cast surface after sandblasting, (B) polished surface after removal of the reaction layer, and (C) sandblasted surface after removal of the reaction layer. Open-circuit potential (OCP) measurement, linear polarization, and potentiodynamic cathodic polarization were performed in aerated (air+10% CO(2)) modified Tani-Zucchi synthetic saliva at 37 degrees C. Potentiodynamic anodic polarization was subsequently conducted in the same medium deaerated with N(2)+10% CO(2) gas 2 h before and during the experiment. Polarization resistance (R(P)) and corrosion rate (I(CORR)) were calculated. Numerical results were subjected to nonparametric statistical analysis at alpha=0.05. The OCP stabilized for all the specimens after 6 x 10(4)s. Apparent differences in anodic polarization were observed among the different surfaces for all the metals. A passivation region followed by breakdown and repassivation were seen on specimens with surfaces A and C. An extensive passive region was observed on all the metals with surface B. The Kruskal-Wallis test showed no significant differences in OCP, R(p), I(CORR) or break down potential for each of the three surfaces among all the metals. The Mann-Whitney test showed significantly lower R(P) and higher I(CORR) values for surface C compared to the other surfaces. Results indicate that the surface condition has more effect on corrosion of these alloys than the surface reaction layer. Within the oxidation potential range of the oral cavity, all the metal

  8. Bioaccumulation of ionic titanium and titanium dioxide nanoparticles in zebrafish eleutheroembryos.

    Science.gov (United States)

    López-Serrano Oliver, Ana; Muñoz-Olivas, Riansares; Sanz Landaluze, Jon; Rainieri, Sandra; Cámara, Carmen

    2015-01-01

    The production of titanium dioxide nanoparticles (TiO(2) NPs) for commercial applications has greatly increased over the last years and consequently the potential risk for human health. There is a growing awareness of the need to understand the behavior and influence these nanoparticles exert on the environment. Bioaccumulation serves as a good integrator to assess chemical exposure in aquatic systems and is dependent on factors, such as the exposure routes, diet and the aqueous medium. We analyzed the experimental bioaccumulation capability of ionic titanium and TiO(2) NPs by zebrafish (Danio rerio) eleutheroembryos through bioconcentration factors (BCFs), after 48 or 72 h of exposure. The stability of both chemical forms in an aquatic medium was fully characterized for further bioaccumulation studies. Several stabilizing agents (humic acids, soluble starch, polyethylene glycol, Na(4)P(2)O(7) and Na(2)HPO(4)) for anatase and rutile, the two allotrophs of TiO(2) NPs, were evaluated to check the evolution of the aggregation process. Around 60% of TiO(2) NPs remained disaggregated under simulated environmental conditions with the addition of 50 mg L(-1) of humic acids. However, the presence of eleutheroembryos in the exposure medium increased TiO(2) NPs aggregation in the experimental tests. The BCFs values obtained in all cases were titanium and TiO(2) NPs as non-bioaccumulative substances, under the REACH regulations.

  9. Production of titanium carbide from ilmenite

    Directory of Open Access Journals (Sweden)

    Sutham Niyomwas

    2008-03-01

    Full Text Available The production of titanium carbide (TiC powders from ilmenite ore (FeTiO3 powder by means of carbothermal reduction synthesis coupled with hydrochloric acid (HCl leaching process was investigated. A mixture of FeTiO3 and carbon powders was reacted at 1500oC for 1 hr under flowing argon gas. Subsequently, synthesized product of Fe-TiC powders were leached by 10% HCl solutions for 24 hrs to get final product of TiC powders. The powders were characterized using X-ray diffraction, scanning electron and transmission electron microscopy. The product particles were agglomerated in the stage after the leaching process, and the size of this agglomerate was 12.8 μm with a crystallite size of 28.8 nm..

  10. Combustion of bulk titanium in oxygen

    Science.gov (United States)

    Clark, A. F.; Moulder, J. C.; Runyan, C. C.

    1975-01-01

    The combustion of bulk titanium in one atmosphere oxygen is studied using laser ignition and several analytical techniques. These were high-speed color cinematography, time and space resolved spectra in the visible region, metallography (including SEM) of specimens quenched in argon gas, X-ray and chemical product analyses, and a new optical technique, the Hilbert transform method. The cinematographic application of this technique for visualizing phase objects in the combustion zone is described. The results indicate an initial vapor phase reaction immediately adjacent to the molten surface but as the oxygen uptake progresses the evaporation approaches the point of congruency and a much reduced evaporation rate. This and the accumulation of the various soluble oxides soon drive the reaction zone below the surface where gas formation causes boiling and ejection of particles. The buildup of rutile cuts off the oxygen supply and the reaction ceases.

  11. Isomerization of -carotene by titanium tetrachloride catalyst

    Indian Academy of Sciences (India)

    V Rajendran; B H Chen

    2007-05-01

    Isomerization of all-trans--carotene occurs during shaking with 0.5% of titanium tetrachloride catalyst in methylene chloride at room temperature. In the present study we compared two types of columns C18 and C30 and various solvent systems for the separation of -carotene and its cis isomers by high performance liquid chromatography (HPLC). Results showed that -carotene isomers were resolved by employing a C30 column with a mobile phase of methanol (100%) (A) and methylene chloride (100%) (B) under a gradient elution condition. A total of eleven cis isomers and one all-trans--carotene isomer were resolved within 50 min at a flow rate of 1 ml/min and detection wave-length of 470 nm.

  12. Preparation and integration of nanostructured titanium dioxide

    KAUST Repository

    Zeng, Hua Chun

    2011-10-01

    Titanium dioxide (TiO2) is a chemically stable nontoxic transition-metal oxide associated with a wide range of existing chemical engineering processes. In this short review, recent research endeavors in preparation and integration of nanostructured TiO2 materials system will be featured and discussed for their potential new applications. Because material development always plays pivotal roles in the progress of a particular engineering discipline, the reviewed subjects will provide useful information to stimulate nanoscale research of chemical engineering, linking established fundamentals with practical applications. Some critical issues and challenges regarding further development of this important functional material for nanotechnology will also be addressed. © 2011 Elsevier Ltd. All rights reserved.

  13. Multifractal characteristics of titanium nitride thin films

    Directory of Open Access Journals (Sweden)

    Ţălu Ştefan

    2015-09-01

    Full Text Available The study presents a multi-scale microstructural characterization of three-dimensional (3-D micro-textured surface of titanium nitride (TiN thin films prepared by reactive DC magnetron sputtering in correlation with substrate temperature variation. Topographical characterization of the surfaces, obtained by atomic force microscopy (AFM analysis, was realized by an innovative multifractal method which may be applied for AFM data. The surface micromorphology demonstrates that the multifractal geometry of TiN thin films can be characterized at nanometer scale by the generalized dimensions Dq and the singularity spectrum f(α. Furthermore, to improve the 3-D surface characterization according with ISO 25178-2:2012, the most relevant 3-D surface roughness parameters were calculated. To quantify the 3-D nanostructure surface of TiN thin films a multifractal approach was developed and validated, which can be used for the characterization of topographical changes due to the substrate temperature variation.

  14. Photoelectrochemical Activity of Graphene Supported Titanium Dioxide

    Directory of Open Access Journals (Sweden)

    Rodrigo A. Segura

    2016-01-01

    Full Text Available Thin TiO2 layers grown over few-layers graphene were prepared in order to evaluate the photoinduced chemical response of this composite. Graphene was grown over copper foils by decomposition of acetylene in a standard chemical vapor deposition apparatus. Graphene was subsequently transferred to a silicon substrate, on which the titanium dioxide was grown to form a TiO2/FLG/SiO2/Si composite. The formation of each layered material was verified by Raman spectroscopy and the morphology was characterized by scanning electron microscopy. The photoelectrochemical evaluation of the resulting composite, using it as a photoanode, was accomplished with a potentiostat, a solar simulator, and a three-electrode configuration. The electrochemical response indicates that the new composite preserves the average photoactive properties of the base material and at the same time shows a singular transient response where explicit benefits seem to be derived from the FLG/TiO2 combination.

  15. In vitro biocompatibility of titanium-nickel alloy with titanium oxide film by H2O2 oxidation

    Institute of Scientific and Technical Information of China (English)

    HU Tao; CHU Cheng-lin; YIN Li-hong; PU Yao-pu; DONG Yin-sheng; GUO Chao; SHENG Xiao-bo; CHUNG Jonathan-CY; CHU Paul-K

    2007-01-01

    Titanium oxide film with a graded interface to NiTi matrix was synthesized in situ on NiTi shape memory alloy(SMA) by oxidation in H2O2 solution. In vitro studies including contact angle measurement, hemolysis, MTT cytotoxicity and cell morphology tests were employed to investigate the biocompatibility of the H2O2-oxidized NiTi SMAs with this titanium oxide film. The results reveal that wettability, blood compatibility and fibroblasts compatibility of NiTi SMA are improved by the coating of titanium oxide film through H2O2 oxidation treatment.

  16. Chemical rate model for the surface pyrolysis of tetrakis(dimethylamido)titanium to form titanium nitride films

    Science.gov (United States)

    Toprac, Anthony J.; Iacoponi, John A.; Littau, Karl A.

    1998-09-01

    A chemical kinetic rate model for the deposition of titanium nitride films from the surface reaction of tetrakis(dimethyl-amido)titanium (TDMAT) was developed. Without ammonia addition, TDMAT forms a titanium nitride film by pyrolyzing on the hot substrate surface. Experimental data from the applied materials 5000 deposition tool was modeled using a CSTR formulation. With the parameters of the surface reaction model regressed to fit portions of the experimental results, reasonably accurate model predictions over the entire domain of experimental data were obtained.

  17. Synthesis of titanium sapphire by ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Morpeth, L.D.; McCallum, J.C.; Nugent, K.W. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1998-06-01

    Since laser action was first demonstrated in titanium sapphire (Ti:Al{sub 2}O{sub 3}) in 1982, it has become the most widely used tunable solid state laser source. The development of a titanium sapphire laser in a waveguide geometry would yield an elegant, compact, versatile and highly tunable light source useful for applications in many areas including optical telecommunications. We are investigating whether ion implantation techniques can be utilised to produce suitable crystal quality and waveguide geometry for fabrication of a Ti:Al{sub 2}O{sub 3} waveguide laser. The implantation of Ti and O ions into c-axis oriented {alpha}-Al{sub 2}O{sub 3} followed by subsequent thermal annealing under various conditions has been investigated as a means of forming the waveguide and optimising the fraction of Ti ions that have the correct oxidation state required for laser operation. A Raman Microprobe is being used to investigate the photo-luminescence associated with Ti{sup 3+} ion. Initial photoluminescence measurements of ion implanted samples are encouraging and reveal a broad luminescence profile over a range of {approx} .6 to .9 {mu}m, similar to that expected from Ti{sup 3+}. Rutherford Backscattering and Ion Channelling analysis have been used to study the crystal structure of the samples following implantation and annealing. This enables optimisation of the implantation parameters and annealing conditions to minimise defect levels which would otherwise limit the ability of light to propagate in the Ti:Al{sub 2O}3 waveguide. (authors). 8 refs., 3 figs.

  18. Bacterial adherence to anodized titanium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Peremarch, C Perez-Jorge; Tanoira, R Perez; Arenas, M A; Matykina, E; Conde, A; De Damborenea, J J; Gomez Barrena, E; Esteban, J, E-mail: cperemarch@fjd.es

    2010-11-01

    The aim of this study was to evaluate Staphylococcus sp adhesion to modified surfaces of anodized titanium alloy (Ti-6Al-4V). Surface modification involved generation of fluoride-containing titanium oxide nanotube films. Specimens of Ti-6Al-4V alloy 6-4 ELI-grade 23- meets the requirements of ASTM F136 2002A (AMS 2631B class A1) were anodized in a mixture of sulphuric/hydrofluoric acid at 20 V for 5 and 60 min to form a 100 nm-thick porous film of 20 nm pore diameter and 230 nm-thick nanotube films of 100 nm in diameter. The amount of fluorine in the oxide films was of 6% and of 4%, respectively. Collection strains and six clinical strains each of Staphylococcus aureus and Staphylococcus epidermidis were studied. The adherence study was performed using a previously published protocol by Kinnari et al. The experiments were performed in triplicates. As a result, lower adherence was detected for collection strains in modified materials than in unmodified controls. Differences between clinical strains were detected for both species (p<0.0001, Kruskal-Wallis test), although global data showed similar results to that of collection strains (p<0.0001, Kruskal-Wallis test). Adherence of bacteria to modified surfaces was decreased for both species. The results also reflect a difference in the adherence between S. aureus and S. epidermidis to the modified material. As a conclusion, not only we were able to confirm the decrease of adherence in the modified surface, but also the need to test multiple clinical strains to obtain more realistic microbiological results due to intraspecies differences.

  19. Plasma electrolytic oxidation of Titanium Aluminides

    Science.gov (United States)

    Morgenstern, R.; Sieber, M.; Grund, T.; Lampke, T.; Wielage, B.

    2016-03-01

    Due to their outstanding specific mechanical and high-temperature properties, titanium aluminides exhibit a high potential for lightweight components exposed to high temperatures. However, their application is limited through their low wear resistance and the increasing high-temperature oxidation starting from about 750 °C. By the use of oxide ceramic coatings, these constraints can be set aside and the possible applications of titanium aluminides can be extended. The plasma electrolytic oxidation (PEO) represents a process for the generation of oxide ceramic conversion coatings with high thickness. The current work aims at the clarification of different electrolyte components’ influences on the oxide layer evolution on alloy TNM-B1 (Ti43.5Al4Nb1Mo0.1B) and the creation of compact and wear resistant coatings. Model experiments were applied using a ramp-wise increase of the anodic potential in order to show the influence of electrolyte components on the discharge initiation and the early stage of the oxide layer growth. The production of PEO layers with technically relevant thicknesses close to 100 μm was conducted in alkaline electrolytes with varying amounts of Na2SiO3·5H2O and K4P2O7 under symmetrically pulsed current conditions. Coating properties were evaluated with regard to morphology, chemical composition, hardness and wear resistance. The addition of phosphates and silicates leads to an increasing substrate passivation and the growth of compact oxide layers with higher thicknesses. Optimal electrolyte compositions for maximum coating hardness and thickness were identified by statistical analysis. Under these conditions, a homogeneous inner layer with low porosity can be achieved. The frictional wear behavior of the compact coating layer is superior to a hard anodized layer on aluminum.

  20. Manufacturing Technology and Application Trends of Titanium Clad Steel Plates

    Institute of Scientific and Technical Information of China (English)

    Hang SU; Xiao-bing LUO; Feng CHAI; Jun-chang SHEN; Xin-jun SUN; Feng LU

    2015-01-01

    Some of the major manufacturing processes and corresponding mechanical properties of titanium clad steel plates were analyzed, and the consequences of research, manufacturing, and application of titanium clad steel plates in both markets of China and overseas were also summarized. As an economical and environmentally friendly technology, the roll bonding process is ex-pected to become the next-generation mainstream process for the manufacturing of titanium clad steel plate. Some of the crucial and most important technical problems of this particular process, including vacuum sealing technology, surface treatment process technology, application of a transition layer, and rolling process, were discussed along with the advantageous mechanical properties and life-cycle economy of these plates processed by this technology. Finally, the market needs, application trends, and requirements of titanium clad steel plate were also considered from industries of petrochemical, shipbuilding, marine, and electric power.

  1. Surface Modifications and Their Effects on Titanium Dental Implants

    Directory of Open Access Journals (Sweden)

    A. Jemat

    2015-01-01

    Full Text Available This review covers several basic methodologies of surface treatment and their effects on titanium (Ti implants. The importance of each treatment and its effects will be discussed in detail in order to compare their effectiveness in promoting osseointegration. Published literature for the last 18 years was selected with the use of keywords like titanium dental implant, surface roughness, coating, and osseointegration. Significant surface roughness played an important role in providing effective surface for bone implant contact, cell proliferation, and removal torque, despite having good mechanical properties. Overall, published studies indicated that an acid etched surface-modified and a coating application on commercial pure titanium implant was most preferable in producing the good surface roughness. Thus, a combination of a good surface roughness and mechanical properties of titanium could lead to successful dental implants.

  2. Surface Modifications and Their Effects on Titanium Dental Implants.

    Science.gov (United States)

    Jemat, A; Ghazali, M J; Razali, M; Otsuka, Y

    2015-01-01

    This review covers several basic methodologies of surface treatment and their effects on titanium (Ti) implants. The importance of each treatment and its effects will be discussed in detail in order to compare their effectiveness in promoting osseointegration. Published literature for the last 18 years was selected with the use of keywords like titanium dental implant, surface roughness, coating, and osseointegration. Significant surface roughness played an important role in providing effective surface for bone implant contact, cell proliferation, and removal torque, despite having good mechanical properties. Overall, published studies indicated that an acid etched surface-modified and a coating application on commercial pure titanium implant was most preferable in producing the good surface roughness. Thus, a combination of a good surface roughness and mechanical properties of titanium could lead to successful dental implants.

  3. Welding of titanium and stainless steel using the composite insert

    Science.gov (United States)

    Cherepanov, A. N.; Mali, V. I.; Orishich, A. M.; Malikov, A. G.; Drozdov, V. O.; Malyutina, Y. N.

    2016-11-01

    The paper concerns the possibility of obtaining a lasting permanent joint of dissimilar metals: technically pure titanium and stainless steel using laser welding and an intermediate composite insert. The insert was a four-layer composition of plates of steel, copper, niobium, and titanium welded by explosion. The material layers used in the insert prevented the molten steel and titanium from mixing, which excluded the formation of brittle intermetallic compounds, such as FeTi and Fe2Ti. The optimization of explosion welding parameters provided a high quality of the four-layer composition and the absence of defects in the area of the joint of insert plates. The results of strength tests showed that values of the ultimate strength and yield of the permanent joint with the composite insert welded by explosion are comparable to the strength characteristics of titanium.

  4. Characterization Of The Graded Microstructure In Powder Sintered Porous Titanium

    Directory of Open Access Journals (Sweden)

    Oak J.-J.

    2015-06-01

    Full Text Available The proposed sintering process produce porosity and functional graded microstructure in the sinterd titanium powders. Titanium powders with different micro sizes were sintered at the proposed temperature region at 1200 and 1300°C for 2h. The apatite-forming on the graded microstructure is observed by immersion test in Hanks balanced salt soluion at 37°C. Sintering condition of titanium powders is estimated by thermogravitmetry-differential thermal analysis (TG-DTA. The synthersied surface structures and apatite-forming ability were characterized by a field emission scanning electron microscopy (FE-SEM observation and energy dispersive X-ray spectroscopy (EDS analysis. As results, these graded microstructure of sintered porous titanium powders reveals apatite-forming ability as osseointegration by calcification in Hanks balanced salt soluion(HBSS at 37°C.

  5. Preparation and characterization of nitrogen-doped titanium dioxides

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    A type of high visible-light active titanium oxinitride(TiO2-xNx) powder was prepared by a simple proc-ess:the calcination of the hydrated titanium dioxide at the atmosphere of ammonia-argon using a tu-bular electric furnace at high temperatures. The hydrated titanium dioxide was synthesized as the precursor of TiO2-xNx using titanic acid as raw material,which came from sulfate technique of produc-ing titanium white. The effects of temperature and reaction time on the nitrogen content,grain size and crystal structure were studied. The visible-light activity and photocatalysis capability of the powder were also investigated.

  6. Synthesis of titanium carbide by induction plasma reactive spray

    Institute of Scientific and Technical Information of China (English)

    JIANG Xian-Liang(蒋显亮); M.Boulos

    2004-01-01

    A novel method capable of sufficient mixing of titanium powder and methane of carbon source was developed in the synthesis of titanium carbide by induction plasma reactive spray. X-ray diffraction analysis, optical microscopy, scanning electron microscopy, and microhardness test were used to characterize the spray-formed deposit.The experimental results show that both primary carburization of the titanium particles inside the plasma flame and secondary carburization of the growing deposit on high temperature substrate contribute to the forming of titanium carbide. The transitional phase of TiC1-x has the same crystal structure as TiC, but has a slightly low lattice constant. The deposit consists of fine grain structure and large grain structure. The fine grain structure, harder than large grain structure, shows grain boundary fracture.

  7. Predictions of titanium alloy properties using thermodynamic modeling tools

    Science.gov (United States)

    Zhang, F.; Xie, F.-Y.; Chen, S.-L.; Chang, Y. A.; Furrer, D.; Venkatesh, V.

    2005-12-01

    Thermodynamic modeling tools have become essential in understanding the effect of alloy chemistry on the final microstructure of a material. Implementation of such tools to improve titanium processing via parameter optimization has resulted in significant cost savings through the elimination of shop/laboratory trials and tests. In this study, a thermodynamic modeling tool developed at CompuTherm, LLC, is being used to predict β transus, phase proportions, phase chemistries, partitioning coefficients, and phase boundaries of multicomponent titanium alloys. This modeling tool includes Pandat, software for multicomponent phase equilibrium calculations, and PanTitanium, a thermodynamic database for titanium alloys. Model predictions are compared with experimental results for one α-β alloy (Ti-64) and two near-β alloys (Ti-17 and Ti-10-2-3). The alloying elements, especially the interstitial elements O, N, H, and C, have been shown to have a significant effect on the β transus temperature, and are discussed in more detail herein.

  8. An Insoluble Titanium-Lead Anode for Sulfate Electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Ferdman, Alla

    2005-05-11

    The project is devoted to the development of novel insoluble anodes for copper electrowinning and electrolytic manganese dioxide (EMD) production. The anodes are made of titanium-lead composite material produced by techniques of powder metallurgy, compaction of titanium powder, sintering and subsequent lead infiltration. The titanium-lead anode combines beneficial electrochemical behavior of a lead anode with high mechanical properties and corrosion resistance of a titanium anode. In the titanium-lead anode, the titanium stabilizes the lead, preventing it from spalling, and the lead sheathes the titanium, protecting it from passivation. Interconnections between manufacturing process, structure, composition and properties of the titanium-lead composite material were investigated. The material containing 20-30 vol.% of lead had optimal combination of mechanical and electrochemical properties. Optimal process parameters to manufacture the anodes were identified. Prototypes having optimized composition and structure were produced for testing in operating conditions of copper electrowinning and EMD production. Bench-scale, mini-pilot scale and pilot scale tests were performed. The test anodes were of both a plate design and a flow-through cylindrical design. The cylindrical anodes were composed of cylinders containing titanium inner rods and fitting over titanium-lead bushings. The cylindrical design allows the electrolyte to flow through the anode, which enhances diffusion of the electrolyte reactants. The cylindrical anodes demonstrate higher mass transport capabilities and increased electrical efficiency compared to the plate anodes. Copper electrowinning represents the primary target market for the titanium-lead anode. A full-size cylindrical anode performance in copper electrowinning conditions was monitored over a year. The test anode to cathode voltage was stable in the 1.8 to 2.0 volt range. Copper cathode morphology was very smooth and uniform. There was no

  9. Study on Crystallization of Titanium Silicalite Zeolite (Ⅱ)

    Institute of Scientific and Technical Information of China (English)

    Lin Min; Zhu Bin; Shu Xingtian; Wang Xieqing

    2009-01-01

    In order to investigate the rules on formation of zeolite during crystallization of titanium silicalite zeolite (TS-1) the X-ray diffractometry and Foulier transform infra-red spectrometry were applied to track the process of crystallization of titanium silicalite zeolite. The research results revealed that at the initial stage of crystallization the interactions between silica gel and titania gel in the polymer blend could gradually lead to the formation of tiny crystal nuclei with complicated structure that could slowly grow up to form molecular sieves. Quite different from the conventional zeolites that use the acid sites as the catalytically active centers, the oxidative reactivity of the titanium silicalite zeolite was not proportional to its crystallinity and is associated with the oxidative centers of titanium contained in the zeolite.

  10. Titanium Loop Heat Pipes for Space Nuclear Radiators Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will develop titanium Loop Heat Pipes (LHPs) that can be used in low-mass space nuclear radiators, such as...

  11. Ion beam mixing of titanium overlayers with hydroxyapaptite substrates

    Energy Technology Data Exchange (ETDEWEB)

    Levine, T.E. [Cornell Univ., Ithaca, NY (United States). Dept. of Materials Science and Engineering; Nastasi, M. [Los Alamos National Lab., NM (United States); Alford, T.L.; Suchicital, C.; Russell, S.; Luptak, K.; Pizziconi, V.; Mayer, J.W. [Arizona State Univ., Tempe, AZ (United States)

    1995-01-01

    The mixing of titanium overlayers with hydroxyapatite (HA) substrates via ion irradiation has been demonstrated. Analysis via secondary ion mass spectroscopy (SIMS) indicates an interfacial broadening of titanium and calcium of the implanted sample compared to that of the unimplanted sample. Attendant to the observed ion beam mixing of titanium into the HA, the oxygen signal of the titanium overlayer increases as a result of ion irradiation. It is supposed that this change is evident of diffusion through the metal layer and possibly from titania formation at the free surface and perovskite formation at the film/substrate interface. This possibility is consistent with thermodynamic predictions. Additionally, the force required to separate the film from the substrate increased as a result of ion irradiation, validating the continued study of ion beam processing of Ti/HA systems towards the improvement of long term fixation of implant devices.

  12. Carbamazepine degradation by photolysis and titanium dioxide photocatalysis.

    Science.gov (United States)

    Im, Jong-Kwon; Son, Hyun-Seok; Kang, Young-Min; Zoh, Kyung-Duk

    2012-07-01

    We investigated the degradation of carbamazepine by photolysis/ultraviolet (UV)-C only and titanium dioxide photocatalysis. The degradation of carbamazepine by UV-only and titanium-dioxide-only (adsorption) reactions were inefficient, however, complete degradation of carbamazepine was observed by titanium dioxide photocatalysis within 30 min. The rate of degradation increased as initial carbamazepine concentration decreased, and the removal kinetics fit well with the Langmuir-Hinshelwood model. The addition of methanol, a radical scavenger, decreased carbamazepine removal, suggesting that the hydroxide radical played an important role during carbamazepine degradation. The addition of oxygen during titanium dioxide photocatalysis accelerated hydroxide radical production, thus improving mineralization activity. The photocatalytic degradation was more efficient at a higher pH, whereas the removal of carbamazepine and acridine (a major intermediate) were more efficient under aerobic conditions. The mineralization of carbamazepine during photocatalysis produced various ionic by-products such as ammonium and nitrate by way of nitrogen dioxide.

  13. Lunar-derived titanium alloys for hydrogen storage

    Science.gov (United States)

    Love, S.; Hertzberg, A.; Woodcock, G.

    1992-01-01

    Hydrogen gas, which plays an important role in many projected lunar power systems and industrial processes, can be stored in metallic titanium and in certain titanium alloys as an interstitial hydride compound. Storing and retrieving hydrogen with titanium-iron alloy requires substantially less energy investment than storage by liquefaction. Metal hydride storage systems can be designed to operate at a wide range of temperatures and pressures. A few such systems have been developed for terrestrial applications. A drawback of metal hydride storage for lunar applications is the system's large mass per mole of hydrogen stored, which rules out transporting it from earth. The transportation problem can be solved by using native lunar materials, which are rich in titanium and iron.

  14. The use of titanium alloys for details of downhole hammers

    Science.gov (United States)

    Popelyukh, A. I.; Repin, A. A.; Alekseev, S. E.; Martyushev, N. V.; Drozdov, Yu Yu

    2016-04-01

    The influence of cementation technology of titanium alloy Ti-Al-Mn on its wear resistance is studied. It is established that after lubrication a friction pair with mineral oil the wear resistance of the cemented titanium alloy is comparable to wear resistance of the tempered steel 12HN3A, and in water medium surpasses it by 1.5 times. Decrease in the tendency to seizure with steel is the main reason for increase of wear resistance of titanium alloy. Industrial tests of the ASH43 hammer have shown that the use of titanium alloys for the manufacture of hammer strikers allows to increase impact capacity by 1.5 times and to increase drilling rate by 30 % compared to hammers with steel strikers.

  15. Caracterisation of Titanium Nitride Layers Deposited by Reactive Plasma Spraying

    Science.gov (United States)

    Roşu, Radu Alexandru; Şerban, Viorel-Aurel; Bucur, Alexandra Ioana; Popescu, Mihaela; Uţu, Dragoş

    2011-01-01

    Forming and cutting tools are subjected to the intense wear solicitations. Usually, they are either subject to superficial heat treatments or are covered with various materials with high mechanical properties. In recent years, thermal spraying is used increasingly in engineering area because of the large range of materials that can be used for the coatings. Titanium nitride is a ceramic material with high hardness which is used to cover the cutting tools increasing their lifetime. The paper presents the results obtained after deposition of titanium nitride layers by reactive plasma spraying (RPS). As deposition material was used titanium powder and as substratum was used titanium alloy (Ti6Al4V). Macroscopic and microscopic (scanning electron microscopy) images of the deposited layers and the X ray diffraction of the coatings are presented. Demonstration program with layers deposited with thickness between 68,5 and 81,4 μm has been achieved and presented.

  16. Current research situation of titanium alloys in China

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Titanium and its alloys possess excellent comprehensive properties, and they are widely used in many fields. China pays great attentions to the research on new titanium alloys. This paper mainly reviews the research on new Ti alloys in China, for example, high strength and high toughness Ti alloys, burn resistant Tialloys, high temperature Ti alloys, low cost Ti alloys and so on.New basic theories on Ti alloys developed in China in recent years are also reviewed.

  17. Characterization of Hydroxyapatite Film on Titanium Substrate by Sputtering Technique

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Radiofrequent magnetron sputtering technique was used to produce calcium phosphate coated on the titanium substrates, and the sputtered coating films were crystallized in an autoclave at 110 ℃ using a low temperature hydrothermal technique. The crystallization of as- sputtered coating film on the titanium substrates were amorphous calcium phosphate film. However, after the hydrothermal technique, calcium phosphate crystals grew and these were columnar crystal. The Ca/ P ratio of sputtered coating films in 1.6 to 2.0.

  18. Study on Titanium Nitride Film Modified for Intraocular Lens

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Objective:To study the characteristics of the intraocular lens using ion beam sputtering depositing titanium nitride thin film on the intraocular lens(IOLs).Methods:To deposite titanium nitride thin film on the top of intraocular lens by ion beam sputtering depositing.We analyzed the surface morphology of intraocular lens through SEM and AFM.We detected intraocular lens resolution through the measurement of intraocular lens.Biocompatibility of intraocular lens is preliminary evaluated in this test.Results:T...

  19. [Castability and accuracy of fit of a titanium casting system].

    Science.gov (United States)

    Klinger, E; Böning, K; Walter, M

    1991-11-01

    The titanium casting system Cyclarc (Morita) was examined for its suitability for the fabrication of dense, fitting restorations. The investment material Titavest CB exhibited no setting expansion. Instead, thermal expansion, highly dependent on the liquid/power ratio and the temperature during preheating, was observed. The castability of unalloyed titanium is fully acceptable for the fabrication of prosthetic restorations. Single crowns showed a high accuracy of fit, if an optimal liquid/power ratio was used for investment.

  20. Spectroscopic and ultrastructural analysis of fluorhydroxyapatite-coated titanium plates

    Energy Technology Data Exchange (ETDEWEB)

    Martini, D.; Ottani, V.; Ruggeri, A. [Bologna Univ. (Italy). Dipt. di Scienze Anatomiche e Fisiopatologia dell' Apparato Locomotore; Raspanti, M. [Insubria Univ. (Italy). Dipt. di Scienze Cliniche e Biologiche; Monti, P.; Taddei, P.; Tinti, A.; Fragnano, C. [Bologna Univ. (Italy). Dipt. di Biochimica ' G. Moruzzi'

    2001-07-01

    This study aimed to describe the chemical, physical and morphological features of the surface of titanium plates coated with porous titanium and fluorhydroxyapatite for surgical implantation. Although the plasma flame spray coating process partially altered the original chemical and physical characteristics of the coatings, the surface morphology of the coated plates seems very favourable for bone integration of the implant. Immersion in simulated body fluid for ten weeks failed to disclose signs of implant dissolution or impaired surface composition. (orig.)

  1. Hydroxyapatite electrodeposition on anodized titanium nanotubes for orthopedic applications

    Energy Technology Data Exchange (ETDEWEB)

    Parcharoen, Yardnapar [Department of Biological Engineering, Faculty of Engineering, King Mongkut' s University of Technology Thonburi, Bangkok (Thailand); Kajitvichyanukul, Puangrat [Center of Excellence on Environmental Research and Innovation, Faculty of Engineering, Naresuan University, Phitsanulok (Thailand); Sirivisoot, Sirinrath [Department of Biological Engineering, Faculty of Engineering, King Mongkut' s University of Technology Thonburi, Bangkok (Thailand); Termsuksawad, Preecha, E-mail: preecha.ter@kmutt.ac.th [Division of Materials Technology, School of Energy, Environment and Materials, King Mongkut' s University of Technology Thonburi, 126 Pracha Uthit Rd., Bang Mod, ThungKhru, Bangkok 10140 (Thailand)

    2014-08-30

    Highlights: • We found that different anodization time of titanium significantly effects on nanotube length which further impacts adhesion strength of hydroxyapatite coating layers. • Adhesion strength of Hydroxyapatite (HA) coated on titanium dioxide nanotubes is better than that of HA coated on titanium plate. • Hydroxyapatite coated on titanium dioxide nanotubes showed higher cell density and better spreading of MC3T3-E1 cells (bone-forming cells) than that coated on titanium plate surface. - Abstract: Nanotubes modification for orthopedic implants has shown interesting biological performances (such as improving cell adhesion, cell differentiation, and enhancing osseointegration). The purpose of this study is to investigate effect of titanium dioxide (TiO{sub 2}) nanotube feature on performance of hydroxyapatite-coated titanium (Ti) bone implants. TiO{sub 2} nanotubes were prepared by anodization using ammonium fluoride electrolyte (NH{sub 4}F) with and without modifiers (PEG400 and Glycerol) at various potential forms, and times. After anodization, the nanotubes were subsequently annealed. TiO{sub 2} nanotubes were characterized by scanning electron microscope and X-ray diffractometer. The amorphous to anatase transformation due to annealing was observed. Smooth and highly organized TiO{sub 2} nanotubes were found when high viscous electrolyte, NH{sub 4}F in glycerol, was used. Negative voltage (−4 V) during anodization was confirmed to increase nanotube thickness. Length of the TiO{sub 2} nanotubes was significantly increased by times. The TiO{sub 2} nanotube was electrodeposited with hydroxyapatite (HA) and its adhesion was estimated by adhesive tape test. The result showed that nanotubes with the tube length of 560 nm showed excellent adhesion. The coated HA were tested for biological test by live/dead cell straining. HA coated on TiO{sub 2} nanotubes showed higher cells density, higher live cells, and more spreading of MC3T3-E1 cells than that

  2. Investigations of Titanium Implants Covered with Hydroxyapatite Layer

    OpenAIRE

    Świeczko – Żurek B.; Bartmański M.

    2016-01-01

    To reduce unfavorable phenomena occurring after introducing an implant into human body various modifications of the surface are suggested. Such modifications may have significant impact on biocompatibility of metallic materials. The titanium and it's alloys are commonly used for joint and dental implants due to their high endurance, low plasticity modulus, good corrosion resistance as well as biocompatibility. Special attention should be given to titanium alloys containing zirconium, tantalum...

  3. Colloidal Plasmonic Titanium Nitride Nanoparticles: Properties and Applications

    CERN Document Server

    Guler, Urcan; Kildishev, Alexander V; Boltasseva, Alexandra; Shalaev, Vladimir M

    2014-01-01

    Optical properties of colloidal plasmonic titanium nitride nanoparticles are examined with an eye on their photothermal via transmission electron microscopy and optical transmittance measurements. Single crystal titanium nitride cubic nanoparticles with an average size of 50 nm exhibit plasmon resonance in the biological transparency window. With dimensions optimized for efficient cellular uptake, the nanoparticles demonstrate a high photothermal conversion efficiency. A self-passivating native oxide at the surface of the nanoparticles provides an additional degree of freedom for surface functionalization.

  4. Corrosion Behaviour of Titanium Anodized Film in Different Corrosive Environments

    Directory of Open Access Journals (Sweden)

    Mr. Sunil D. Kahar

    2014-07-01

    Full Text Available Anodizing is an electrochemical process in which thickness of the natural oxide layer is increased and converted it into a decorative, durable, corrosion-resistant film. Titanium is used as a biocompatible material in human implants due to its excellent corrosion and wears resistance. Stable, continuous, highly adherent, and protective oxide films can be developed on titanium using various acid or alkaline baths. Anodizing of titanium generates a spectrum of different color without use of dyes. This spectrum of color dependent on the thickness of the oxide, voltage ranges, interference of light reflecting off the oxide surface and reflecting off the underlying metal surface. The anodized film of Titanium is mainly consists of TiO2 or mixtures of TiO2 & Ti2O3 etc. In the present work, Pure Titanium plate has been anodized using bath of Chromic Acid at different voltage range. The anodized film is characterized by visual observation, SEM & EDAX analysis & A.C Impedance Spectroscopy, while the corrosion studies were performed using Potentiodynamic studies were performed in 3.5% NaCl & 0.1N H2SO4. The Results show that the anodized film of Titanium show different spectrum of colors from Brown-Violet-Tea or Peacock. SEM & EDAX analyses show that the anodized film of Titanium is mainly made up of TiO2 and Ti2O3. Potentiodynamic study implies that the film developed on Titanium using the bath of Chromic Acid exhibits good corrosion resistance. The A.C. Impedance study shows that the film is more compact, adherent and more uniform in chromic acid bath.

  5. Plasma functionalization of titanium surface for repulsion of blood platelets

    OpenAIRE

    Cvelbar, Uros; Modic, Martina; Kovac, J.; Lazovic, S; Filipic, G; Vujosevic, D; Junkar, Ita; Elersic, Kristina; Brühl, S.P.; Canal Barnils, Cristina; Belmonte, Thierry; Mozetic, Miran

    2012-01-01

    Thrombosis and restenosis are the most common problems during insertion of biocompatible implants like titanium stents into human blood, due to aggregation of platelets on their surfaces. Because of this reason, we studied the response of blood platelets to a plasma treated titanium surface. The aim was to design a functionalized surface which would repel blood platelets or prevent their adhesion. Therefore, we functionalized surfaces with low-temperature inductively coupled oxygen plasma tre...

  6. Enhanced ultrasonically assisted turning of a β-titanium alloy.

    Science.gov (United States)

    Maurotto, Agostino; Muhammad, Riaz; Roy, Anish; Silberschmidt, Vadim V

    2013-09-01

    Although titanium alloys have outstanding mechanical properties such as high hot hardness, a good strength-to-weight ratio and high corrosion resistance; their low thermal conductivity, high chemical affinity to tool materials severely impair their machinability. Ultrasonically assisted machining (UAM) is an advanced machining technique, which has been shown to improve machinability of a β-titanium alloy, namely, Ti-15-3-3-3, when compared to conventional turning processes.

  7. Candida albicans biofilm on titanium: effect of peroxidase precoating

    Directory of Open Access Journals (Sweden)

    Mohamed Ahariz

    2010-08-01

    Full Text Available Mohamed Ahariz1, Philippe Courtois1,21Laboratory of Experimental Hormonology, Université Libre de Bruxelles, Brussels, 2UER de Biologie Médicale, Haute Ecole Francisco Ferrer, Brussels, BelgiumAbstract: The present study aimed to document Candida albicans biofilm development on titanium and its modulation by a peroxidase-precoated material which can generate antimicrobials, such as hypoiodite or hypothiocyanite, from hydrogen peroxide, iodide, or thiocyanate. For this purpose, titanium (powder or foil was suspended in Sabouraud liquid medium inoculated with C. albicans ATCC10231. After continuous stirring for 2–21 days at room temperature, the supernatant was monitored by turbidimetry at 600 nm and titanium washed three times in sterile Sabouraud broth. Using the tetrazolium salt MTT-formazan assay, the titanium-adherent fungal biomass was measured as 7.50 ± 0.60 × 106 blastoconidia per gram of titanium powder (n = 30 and 0.50 ± 0.04 × 106 blastoconidia per cm² of titanium foil (n = 12. The presence of yeast on the surface of titanium was confirmed by microscopy both on fresh preparations and after calcofluor white staining. However, in the presence of peroxidase systems (lactoperoxidase with substrates such as hydrogen peroxide donor, iodide, or thiocyanate, Candida growth in both planktonic and attached phases appeared to be inhibited. Moreover, this study demonstrates the possible partition of peroxidase systems between titanium material (peroxidase-precoated and liquid environment (containing peroxidase substrates to limit C. albicans biofilm formation.Keywords: adhesion, material, oral, yeast

  8. Modeling corrosion behavior of gas tungsten arc welded titanium alloy

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The pitting corrosion characteristics of pulse TIG welded Ti-6Al-4V titanium alloy in marine environment were explained.Besides the rapid advance of titanium metallurgy, this is also due to the successful solution of problems associated with the development of titanium alloy welding. The preferred welding process of titanium alloy is frequently gas tungsten arc(GTA) welding due to its comparatively easier applicability and better economy. In the case of single pass GTA welding of thinner section of this alloy, the pulsed current has been found beneficial due to its advantages over the conventional continuous current process. The benefit of the process is utilized to obtain better quality titanium weldments. Four factors, five levels, central composite, rotatable design matrix are used to optimize the required number of experiments. The mathematical models have been developed by response surface method(RSM). The results reveal that the titanium alloy can form a protective scale in marine environment and is resistant to pitting corrosion. Experimental results are provided to illustrate the proposed approach.

  9. The synthesis of titanium carbide-reinforced carbon nanofibers.

    Science.gov (United States)

    Zhu, Pinwen; Hong, Youliang; Liu, Bingbing; Zou, Guangtian

    2009-06-24

    Tailoring hard materials into nanoscale building blocks can greatly extend the applications of hard materials and, at the same time, also represents a significant challenge in the field of nanoscale science. This work reports a novel process for the preparation of carbon-based one-dimensional hard nanomaterials. The titanium carbide-carbon composite nanofibers with an average diameter of 90 nm are prepared by an electrospinning technique and a high temperature pyrolysis process. A composite solution containing polyacrylonitrile and titanium sources is first electrospun into the composite nanofibers, which are subsequently pyrolyzed to produce the desired products. The x-ray diffraction pattern and transmission electron microscopy results show that the main phase of the as-synthesized nanofibers is titanium carbide. The Raman analyses show that the composite nanofibers have low graphite clusters in comparison with the pure carbon nanofibers originating from the electrospun polyacrylonitrile nanofibers. The mechanical property tests demonstrate that the titanium carbide-carbon nanofiber membranes have four times higher tensile strength than the carbon nanofiber membranes, and the Young's modulus of the titanium carbide-carbon nanofiber membranes increases in direct proportion to the titanium quantity.

  10. Biofunctionalization of titanium surfaces for osseintegration process improvement

    Energy Technology Data Exchange (ETDEWEB)

    Sevilla, P; Godoy, M; Salvagni, E; Rodriguez, D; Gil, F J, E-mail: pablo.sevilla@upc.edu

    2010-11-01

    This study aims to improve the osseointegration of titanium implants through surface immobilization of peptides that induce a beneficial biological response. This was carried out biofunctionalizating titanium surfaces by silanization and subsequent covalent binding of a peptide with a sequence that promotes cell adhesion. Objective: The development of a new technique of immobilization of oligopeptides on the surface of titanium by using 3-chloropropyltrietoxisilane (CPTES) as bonding agent between the surface of titanium and the peptide. Materials and methods: A physicochemical characterization of the surfaces through the techniques of XPS, ToF-SIMS and contact angle was performed. Also cell adhesion studies have been conducted to evaluate in vitro biological response. Results: Through the process of silanization the titanium surface is completely covered with CPTES, which allows the subsequent accession of oligopeptides. The cell adhesion results show a higher cell adhesion and cell extension on biofunctionalized samples. Conclusions: We developed a system of covalent binding of oligopeptides on titanium surfaces that can modify the biological response of the attached cells.

  11. Formation of Biomimetic Hydroxyapatite Coating on Titanium Plates

    Directory of Open Access Journals (Sweden)

    Ievgen Volodymyrovych PYLYPCHUK

    2014-09-01

    Full Text Available Hydroxyapatite (HA has long been used as a coating material in the implant industry for orthopedic implant applications. HA is the natural inorganic constituent of bone and teeth. By coating titanium (base material of implant engineering because of its lightness and durability with hydroxyapatite, we can provide higher biocompatibility of titanium implants, according to HA ability to form a direct biochemical bond with living tissues. This article reports a biomimetic approach for coating hydroxyapatite with titanium A method of modifying the surface of titanium by organic modifiers (for creating functional groups on the surface, followed by formation "self-assembled" layer of biomimetic hydroxyapatite in simulated body fluid (SBF. FTIR and XPS confirmed the formation of hydroxyapatite coatings on titanium surface. Comparative study of the formation of HA on the surface of titanium plates modified by different functional groups: Ti(≡OH, Ti/(≡Si-OH and Ti/(≡COOH is conducted. It was found that the closest to natural stoichiometric hydroxyapatite Ca/P ratio was obtained on Ti/(≡COOH samples. DOI: http://dx.doi.org/10.5755/j01.ms.20.3.4974

  12. Adhesion of osteoblasts to a nanorough titanium implant surface

    Directory of Open Access Journals (Sweden)

    Gongadze E

    2011-08-01

    Full Text Available Ekaterina Gongadze1, Doron Kabaso2, Sebastian Bauer3, Tomaž Slivnik2, Patrik Schmuki3, Ursula van Rienen1, Aleš Iglič21Institute of General Electrical Engineering, University of Rostock, Rostock, Germany; 2Laboratory of Biophysics, Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia; 3Department of Materials Science, Friedrich-Alexander University of Erlangen-Nurenberg, Erlangen, GermanyAbstract: This work considers the adhesion of cells to a nanorough titanium implant surface with sharp edges. The basic assumption was that the attraction between the negatively charged titanium surface and a negatively charged osteoblast is mediated by charged proteins with a distinctive quadrupolar internal charge distribution. Similarly, cation-mediated attraction between fibronectin molecules and the titanium surface is expected to be more efficient for a high surface charge density, resulting in facilitated integrin mediated osteoblast adhesion. We suggest that osteoblasts are most strongly bound along the sharp convex edges or spikes of nanorough titanium surfaces where the magnitude of the negative surface charge density is the highest. It is therefore plausible that nanorough regions of titanium surfaces with sharp edges and spikes promote the adhesion of osteoblasts.Keywords: osteoblasts, nanostructures, adhesion, titanium implants, osteointegration

  13. Human Mesenchymal Stem Cell Morphology and Migration on Microtextured Titanium

    Science.gov (United States)

    Banik, Brittany L.; Riley, Thomas R.; Platt, Christina J.; Brown, Justin L.

    2016-01-01

    The implant used in spinal fusion procedures is an essential component to achieving successful arthrodesis. At the cellular level, the implant impacts healing and fusion through a series of steps: first, mesenchymal stem cells (MSCs) need to adhere and proliferate to cover the implant; second, the MSCs must differentiate into osteoblasts; third, the osteoid matrix produced by the osteoblasts needs to generate new bone tissue, thoroughly integrating the implant with the vertebrate above and below. Previous research has demonstrated that microtextured titanium is advantageous over smooth titanium and PEEK implants for both promoting osteogenic differentiation and integrating with host bone tissue; however, no investigation to date has examined the early morphology and migration of MSCs on these surfaces. This study details cell spreading and morphology changes over 24 h, rate and directionality of migration 6–18 h post-seeding, differentiation markers at 10 days, and the long-term morphology of MSCs at 7 days, on microtextured, acid-etched titanium (endoskeleton), smooth titanium, and smooth PEEK surfaces. The results demonstrate that in all metrics, the two titanium surfaces outperformed the PEEK surface. Furthermore, the rough acid-etched titanium surface presented the most favorable overall results, demonstrating the random migration needed to efficiently cover a surface in addition to morphologies consistent with osteoblasts and preosteoblasts. PMID:27243001

  14. Effects of thickness on electronic structure of titanium thin films

    Indian Academy of Sciences (India)

    Güvenç Akgül

    2014-02-01

    Effects of thickness on the electronic structure of e-beam evaporated thin titanium films were studied using near-edge X-ray absorption fine structure (NEXAFS) technique at titanium 2,3 edge in total electron yield (TEY) mode and transmission yield mode. Thickness dependence of 2,3 branching ratio (BR) of titanium was investigated and it was found that BR below 3.5 nm shows a strong dependence on film thickness. Mean electron escape depth () in titanium, an important parameter for surface applications, was determined to be = 2.6 ± 0.1 nm using 2,3 resonance intensity variation as a function of film thickness. The average 3/2 white line intensity ratio of titanium was obtained as 0.89 from the ratio of amplitudes of each 3 and 2 peaks and 0.66 from the integrated area under each 3 and 2 peaks. In addition, a theoretical calculation for pure titanium was presented for comparison with experimental data.

  15. Nanoscale Bonding between Human Bone and Titanium Surfaces: Osseohybridization

    Directory of Open Access Journals (Sweden)

    Jun-Sik Kim

    2015-01-01

    Full Text Available Until now, the chemical bonding between titanium and bone has been examined only through a few mechanical detachment tests. Therefore, in this study, a sandblasted and acid-etched titanium mini-implant was removed from a human patient after 2 months of placement in order to identify the chemical integration mechanism for nanoscale osseointegration of titanium implants. To prepare a transmission electron microscopy (TEM specimen, the natural state was preserved as much as possible by cryofixation and scanning electron microscope/focused ion beam (SEM-FIB milling without any chemical treatment. High-resolution TEM (HRTEM, energy dispersive X-ray spectroscopy (EDS, and scanning TEM (STEM/electron energy loss spectroscopic analysis (EELS were used to investigate the chemical composition and structure at the interface between the titanium and bone tissue. HRTEM and EDS data showed evidence of crystalline hydroxyapatite and intermixing of bone with the oxide layer of the implant. The STEM/EELS experiment provided particularly interesting results: carbon existed in polysaccharides, calcium and phosphorus existed as tricalcium phosphate (TCP, and titanium existed as oxidized titanium. In addition, the oxygen energy loss near edge structures (ELNESs showed a possibility of the presence of CaTiO3. These STEM/EELS results can be explained by structures either with or without a chemical reaction layer. The possible existence of the osseohybridization area and the form of the carbon suggest that reconsideration of the standard definition of osseointegration is necessary.

  16. Effect of cathodic polarization on coating doxycycline on titanium surfaces.

    Science.gov (United States)

    Geißler, Sebastian; Tiainen, Hanna; Haugen, Håvard J

    2016-06-01

    Cathodic polarization has been reported to enhance the ability of titanium based implant materials to interact with biomolecules by forming titanium hydride at the outermost surface layer. Although this hydride layer has recently been suggested to allow the immobilization of the broad spectrum antibiotic doxycycline on titanium surfaces, the involvement of hydride in binding the biomolecule onto titanium remains poorly understood. To gain better understanding of the influence this immobilization process has on titanium surfaces, mirror-polished commercially pure titanium surfaces were cathodically polarized in the presence of doxycycline and the modified surfaces were thoroughly characterized using atomic force microscopy, electron microscopy, secondary ion mass spectrometry, and angle-resolved X-ray spectroscopy. We demonstrated that no hydride was created during the polarization process. Doxycycline was found to be attached to an oxide layer that was modified during the electrochemical process. A bacterial assay using bioluminescent Staphylococcus epidermidis Xen43 showed the ability of the coating to reduce bacterial colonization and planktonic bacterial growth.

  17. The immunomodulatory effects of titanium dioxide and silver nanoparticles.

    Science.gov (United States)

    Lappas, Courtney M

    2015-11-01

    Due to their characteristic physical, chemical and optical properties, titanium dioxide and silver nanoparticles are attractive tools for use in a wide range of applications. The use of nanoparticles for biological applications is, however, dependent upon their biocompatibility with living cells. Because of the importance of inflammation as a modulator of human health, the safe and efficacious in vivo use of titanium dioxide and silver nanoparticles is inherently linked to a favorable interaction with immune system cells. However, both titanium dioxide and silver nanoparticles have demonstrated potential to exert immunomodulatory and immunotoxic effects. Titanium dioxide and silver nanoparticles are readily internalized by immune system cells, may accumulate in peripheral lymphoid organs, and can influence multiple manifestations of immune cell activity. Although the factors influencing the biocompatibility of titanium dioxide and silver nanoparticles with immune system cells have not been fully elucidated, nanoparticle core composition, size, concentration and the duration of cell exposure seem to be important. Because titanium dioxide and silver nanoparticles are widely utilized in pharmaceutical, commercial and industrial products, it is vital that their effects on human health and immune system function be more thoroughly evaluated.

  18. Biocompatibility of beta-stabilizing elements of titanium alloys.

    Science.gov (United States)

    Eisenbarth, E; Velten, D; Müller, M; Thull, R; Breme, J

    2004-11-01

    In comparison to the presently used alpha + beta titanium alloys for biomedical applications, beta-titanium alloys have many advantageous mechanical properties, such as an improved wear resistance, a high elasticity and an excellent cold and hot formability. This will promote their future increased application as materials for orthopaedic joint replacements. Not all elements with beta-stabilizing properties in titanium alloys are suitable for biomaterial applications-corrosion and wear processes cause a release of these alloying elements to the surrounding tissue. In this investigation, the biocompability of alloying elements for beta- and near beta-titanium alloys was tested in order to estimate their suitability for biomaterial components. Titanium (grade 2) and the implant steel X2CrNiMo18153 (AISI 316 L) were tested as reference materials. The investigation included the corrosion properties of the elements, proliferation, mitochondrial activity, cell morphology and the size of MC3T3-E1 cells and GM7373 cells after 7 days incubation in direct contact with polished slices of the metals. The statistical significance was considered by Weir-test and Lord-test (alpha = 0.05). The biocompatibility range of the investigated metals is (decreasing biocompatibility): niobium-tantalum, titanium, zirconium-aluminium-316 L-molybdenum.

  19. Surface modification by alkali and heat treatments in titanium alloys.

    Science.gov (United States)

    Lee, Baek-Hee; Do Kim, Young; Shin, Ji Hoon; Hwan Lee, Kyu

    2002-09-01

    Pure titanium and titanium alloys are normally used for orthopedic and dental prostheses. Nevertheless, their chemical, biological, and mechanical properties still can be improved by the development of new preparation technologies. This has been the limiting factor for these metals to show low affinity to living bone. The purpose of this study is to improve the bone-bonding ability between titanium alloys and living bone through a chemically activated process and a thermally activated one. Two kinds of titanium alloys, a newly designed Ti-In-Nb-Ta alloy and a commercially available Ti-6Al-4V ELI alloy, were used in this study. In this study, surface modification of the titanium alloys by alkali and heat treatments (AHT), alkali treated in 5.0M NaOH solution, and heat treated in vacuum furnace at 600 degrees C, is reported. After AHT, the effects of the AHT on the bone integration property were evaluated in vitro. Surface morphologies of AHT were observed by optical microscopy (OM) and scanning electron microscopy (SEM). Chemical compositional surface changes were investigated by X-ray diffractometry (XRD), energy dispersive spectroscopy (EDS), and auger electron spectroscopy (AES). Titanium alloys with surface modification by AHT showed improved bioactive behavior, and the Ti-In-Nb-Ta alloy had better bioactivity than the Ti-6Al-4V ELI alloy in vitro.

  20. Properties of titanium-alloyed DLC layers for medical applications.

    Science.gov (United States)

    Joska, Ludek; Fojt, Jaroslav; Cvrcek, Ladislav; Brezina, Vitezslav

    2014-01-01

    DLC-type layers offer a good potential for application in medicine, due to their excellent tribological properties, chemical resistance, and bio-inert character. The presented study has verified the possibility of alloying DLC layers with titanium, with coatings containing three levels of titanium concentration prepared. Titanium was present on the surface mainly in the form of oxides. Its increasing concentration led to increased presence of titanium carbide as well. The behavior of the studied systems was stable during exposure in a physiological saline solution. Electrochemical impedance spectra practically did not change with time. Alloying, however, changed the electrochemical behavior of coated systems in a significant way: from inert surface mediating only exchange reactions of the environment in the case of unalloyed DLC layers to a response corresponding rather to a passive surface in the case of alloyed specimens. The effect of DLC layers alloying with titanium was tested by the interaction with a simulated body fluid, during which precipitation of a compound containing calcium and phosphorus--basic components of the bone apatite--occurred on all doped specimens, in contrast to pure DLC. The results of the specimens' surface colonization with cells test proved the positive effect of titanium in the case of specimens with a medium and highest content of this element.

  1. Comparison of cementless and bone-cement protheses in total hip arthroplasty for osteoporotic femoral neck fracture in elderly patients%生物型和骨水泥型股骨假体全髋关节置换术治疗老年骨质疏松性股骨颈骨折的临床效果对比

    Institute of Scientific and Technical Information of China (English)

    王华国; 叶劲; 邹仲兵; 白波

    2014-01-01

    Objective To compare the therapeutic effects of bone-cement stem and cementless stem used in the total hip arthroplasty ( THA) for treating the osteoporotic fracture of the femoral neck in the senile patients .Methods A retrospective study was carried out to analyse 100 cases of osteoporotic femoral neck fracture in the elderly patients who underwent THA in our hospital .The patients were divided into two groups by the operation methods:group A, 60 cases applied bone-cement stem in THA;group B, 40 cases applied cementless stem in THA .The hip joint function , the motion range of the joint , the imaging characteristics of the hip and posoperative pain were all compared between the two groups . Results Therewere significant differences in the clinical therapeutic effects between the two groups ( P<0.05).Conclusions The postoperative effects of the bone-cement stem is much better than the cementless stem in THA for the osteoporotic femoral neck fracture in elderly , but it may cause the risks of deep venous thromboembolism and bone cement crisis .%目的:对比老年骨质疏松股骨颈骨折使用生物型股骨假体柄与骨水泥型股骨假体柄行全髋关节置换术治疗效果。方法对本组进行老年骨质疏松股骨颈骨折100例(100髋)进行的全髋关节置换术根据手术方式分为A组(股骨假体柄骨水泥型全髋关节置换术,60髋), B组(股骨假体柄生物型全髋关节置换术,40髋)。对比两组髋关节功能、关节活动度、髋关节影像学特点及术后疼痛情况。结果老年骨质疏松股骨颈骨折行全髋关节置换术,采用生物型股骨假体柄与骨水泥型股骨假体柄的全髋关节置换术临床疗效对比差异显著( P<0.05)。结论对于老年骨质疏松股骨颈骨折行全髋关节置换术,应用骨水泥型者股骨假体柄术后近期疗效明显优于生物型,但它有诱发深静脉血栓栓塞和骨水泥危象的风险。

  2. Cadmium Telluride-Titanium Dioxide Nanocomposite for Photodegradation of Organic Substance.

    Science.gov (United States)

    Ontam, Areeporn; Khaorapapong, Nithima; Ogawa, Makoto

    2015-12-01

    Cadmium telluride-titanium dioxide nanocomposite was prepared by hydrothermal reaction of sol-gel derived titanium dioxide and organically modified cadmium telluride. The crystallinity of titanium dioxide in the nanocomposite was higher than that of pure titanium dioxide obtained by the reaction under the same temperature and pressure conditions, showing that cadmium telluride induced the crystallization of titanium dioxide. Diffuse reflectance spectrum of the nanocomposite showed the higher absorption efficiency in the UV-visible region due to band-gap excitation of titanium dioxide. The nanocomposite significantly showed the improvement of photocatalytic activity for 4-chlorophenol with UV light.

  3. Improving Osteoblast Response In Vitro by a Nanostructured Thin Film with Titanium Carbide and Titanium Oxides Clustered around Graphitic Carbon.

    Directory of Open Access Journals (Sweden)

    Giovanni Longo

    Full Text Available Recently, we introduced a new deposition method, based on Ion Plating Plasma Assisted technology, to coat titanium implants with a thin but hard nanostructured layer composed of titanium carbide and titanium oxides, clustered around graphitic carbon. The nanostructured layer has a double effect: protects the bulk titanium against the harsh conditions of biological tissues and in the same time has a stimulating action on osteoblasts.The aim of this work is to describe the biological effects of this layer on osteoblasts cultured in vitro. We demonstrate that the nanostructured layer causes an overexpression of many early genes correlated to proteins involved in bone turnover and an increase in the number of surface receptors for α3β1 integrin, talin, paxillin. Analyses at single-cell level, by scanning electron microscopy, atomic force microscopy, and single cell force spectroscopy, show how the proliferation, adhesion and spreading of cells cultured on coated titanium samples are higher than on uncoated titanium ones. Finally, the chemistry of the layer induces a better formation of blood clots and a higher number of adhered platelets, compared to the uncoated cases, and these are useful features to improve the speed of implant osseointegration.In summary, the nanostructured TiC film, due to its physical and chemical properties, can be used to protect the implants and to improve their acceptance by the bone.

  4. Synthesis of self-ordered titanium oxide nanotubes by anodization of titanium

    Science.gov (United States)

    Krishnan, A. Yaadhav; Sivabalan, S.; Subhachandhar, S.; Balakrishnan, M.; Narayanan, R.

    2012-07-01

    Self-ordered arrays of titanium oxide nanotubes were prepared by anodization of Ti in sodium sulphate solution containing sodium fluoride. The dimensions of the nanotubes (diameter: 20-100 nm and length: 1000-1500 nm) could be tuned by changing the synthesis parameters. The as-anodized nanotubes showed amorphous structure which upon annealing at 500°C in oxygen atmosphere turned crystalline, according to XRD analysis. The pit morphologies show that pit initiation occurs due to NaF content in the electrolyte and nanotube formation starts after pit growth terminates.

  5. Computer precision simulation for titanium casting centrifugal mold filling of prescision titanium castings

    Directory of Open Access Journals (Sweden)

    Daming XU

    2004-08-01

    Full Text Available Computer simulation codes were developed based on proposed mathematical model for centrifugal mold filling processes and previous computer software for 3D mold filling and solidification of castings. Sample simulations were implemented for mold filling processes of precision titanium castings under gravity and different centrifugal casting techniques. The computation results show that the alloy melt has a much stronger mold filling ability for thin section castings unde a centrifugal force field than that only under the gravity. A "return back" mold filling manner is showed to be a reasonable technique for centrifugal casting processes, especially for thin section prcision castings.

  6. A new route for the synthesis of titanium silicalite-1

    Energy Technology Data Exchange (ETDEWEB)

    Vasile, Aurelia, E-mail: aurelia_vasile@yahoo.com [Laboratory of Materials Chemistry, Faculty of Chemistry, ' Al.I. Cuza' University of Iasi, B-dul Carol I, No. 11, 700506 Iasi (Romania); Busuioc-Tomoiaga, Alina Maria [Laboratory of Materials Chemistry, Faculty of Chemistry, ' Al.I. Cuza' University of Iasi, B-dul Carol I, No. 11, 700506 Iasi (Romania); Catalysis Research Department, ChemPerformance SRL, Iasi 700337 (Romania)

    2012-01-15

    Graphical abstract: Well-prepared TS-1 was synthesized by an innovative procedure using inexpensive reagents such as fumed silica and TPABr as structure-directing agent. This is the first time when highly crystalline TS-1 is obtained in basic medium, using sodium hydroxide as HO{sup -} ion source required for the crystallization process. Hydrolysis of titanium source has been prevented by titanium complexation with acetylacetone before structuring gel. Highlights: Black-Right-Pointing-Pointer TS-1 was obtained using cheap reagents as fumed silica and tetrapropylammonium bromide. Black-Right-Pointing-Pointer First time NaOH was used as source of OH{sup -} ions required for crystallization process. Black-Right-Pointing-Pointer The hydrolysis Ti alkoxides was controlled by Ti complexation with 2,4-pentanedione. -- Abstract: A new and efficient route using inexpensive reagents such as fumed silica and tetrapropylammonium bromide is proposed for the synthesis of titanium silicalite-1. High crystalline titanium silicalite-1 was obtained in alkaline medium, using sodium hydroxide as HO{sup -} ion source required for the crystallization process. Hydrolysis of titanium source with formation of insoluble oxide species was prevented by titanium complexation with before structuring gel. The final solids were fully characterized by powder X-ray diffraction, scanning electron microscopy, Fourier transform infrared, ultraviolet-visible diffuse reflectance, Raman and atomic absorption spectroscopies, as well as nitrogen sorption analysis. It was found that a molar ratio Ti:Si of about 0.04 in the initial reaction mixture is the upper limit to which well formed titanium silicalite-1 with channels free of crystalline or amorphous material can be obtained. Above this value, solids with MFI type structure containing both Ti isomorphously substituted in the network and extralattice anatase nanoparticles inside of channels is formed.

  7. Fully CMOS-compatible titanium nitride nanoantennas

    Science.gov (United States)

    Briggs, Justin A.; Naik, Gururaj V.; Petach, Trevor A.; Baum, Brian K.; Goldhaber-Gordon, David; Dionne, Jennifer A.

    2016-02-01

    CMOS-compatible fabrication of plasmonic materials and devices will accelerate the development of integrated nanophotonics for information processing applications. Using low-temperature plasma-enhanced atomic layer deposition (PEALD), we develop a recipe for fully CMOS-compatible titanium nitride (TiN) that is plasmonic in the visible and near infrared. Films are grown on silicon, silicon dioxide, and epitaxially on magnesium oxide substrates. By optimizing the plasma exposure per growth cycle during PEALD, carbon and oxygen contamination are reduced, lowering undesirable loss. We use electron beam lithography to pattern TiN nanopillars with varying diameters on silicon in large-area arrays. In the first reported single-particle measurements on plasmonic TiN, we demonstrate size-tunable darkfield scattering spectroscopy in the visible and near infrared regimes. The optical properties of this CMOS-compatible material, combined with its high melting temperature and mechanical durability, comprise a step towards fully CMOS-integrated nanophotonic information processing.

  8. Biomolecule-coated metal nanoparticles on titanium.

    Science.gov (United States)

    Christensen, Stephen L; Chatt, Amares; Zhang, Peng

    2012-02-07

    Immobilizations of nanoparticles and biomolecules on biocompatible substrates such as titanium are two promising approaches to bringing new functionalities to Ti-based biomaterials. Herein, we used a variety of X-ray spectroscopic techniques to study and better understand metal-thiolate interactions in biofunctionalized metal nanoparticle systems supported on Ti substrates. Using a facile one-step procedure, a series of Au nanoparticle samples with varied biomolecule coatings ((2-mercatopropionyl)glycine (MPG) and bovine serum albumin (BSA)) and biomolecule concentrations are prepared. Ag and Pd systems are also studied to observe change with varying metal composition. The structure and properties of these biomolecule-coated nanoparticles are investigated with scanning electron microscopy (SEM) and element-specific X-ray techniques, including extended X-ray absorption fine structure (Au L(3)-edge), X-ray absorption near-edge structure (Au L(3), Ag L(3), Pd L(3), and S K-edge), and X-ray photoelectron spectroscopy (Au 4f, Ag 3d, Pd 3d, and S 2p core level). It was found that, by comparison of SEM and X-ray spectroscopy results, the coating of metal nanoparticles with varying model biomolecule systems can have a significant effect on both surface coverage and organization. This work offers a facile chemical method for bio- and nanofunctionalization of Ti substrates as well as provides a physical picture of the structure and bonding of biocoated metal nanoparticles, which may lead to useful applications in orthopedics and biomedicine.

  9. Cell attachment on ion implanted titanium surface

    Directory of Open Access Journals (Sweden)

    P.S. Sreejith

    2008-12-01

    Full Text Available Purpose: Of outmost importance for the successful use of an implant is a good adhesion of the surrounding tissue to the biomaterial. In addition to the surface composition of the implant, the surface topography also influences the properties of the adherent cells. In the present investigation, ion implanted and untreated surfaces were compared for cell adhesion and spreading.Design/methodology/approach: The surface topography of the surfaces were analyzed using AFM and the cell studies with SEM.Findings: The results of our present investigation is indicative of the fact that ion implanted titanium surface offer better cell binding affinity compared to untreated/polished surface.Practical implications: Success of non-biodegradable implants will first and foremost depend on biocompatibility, followed by the capacity of the surface topography of the implants to evince desired cell matrix, surface cell matrix interactions. In the present study, the cell growth on ion implanted Ti material is analyzed and discussed.Originality/value: In this paper, we have utilized ion implantation technique, which will produce nano-texturing of the surface without producing any detrimental effects to both the dimensions and properties of the implants.

  10. Electrochemical Investigation of Doped Titanium Dioxide

    Directory of Open Access Journals (Sweden)

    J. W. J. Hamilton

    2008-01-01

    Full Text Available Thin films of transition-metal doped (0.2, 1.0, and 5.0 atom% TiO2 were prepared on titanium foil using a sol-gel route catalyzed by ammonium acetate. Dopants investigated were the fourth-period transition metals. The prepared films were characterised by Raman spectroscopy, Auger electron spectroscopy, and photoelectrochemical methods. The films doped with transition metals showed a lower photocurrent response than undoped samples. No major red shift in the photocurrent response spectra of the doped films was observed. A photocurrent response was observed under visible light irradiation of the samples and was potential dependent peaking around −0.3 V (SCE, which is indicative of electron promotion from a filled defect level. Examination of the defect level potential dependence by analysis of the current-time response under chopped illumination at fixed potential (−0.8 V–+1.07 V gave a good correlation with the potential dependence observed in the visible light irradiation studies.

  11. Nonlinear Refractory Plasmonics with Titanium Nitride Nanoantennas.

    Science.gov (United States)

    Gui, Lili; Bagheri, Shahin; Strohfeldt, Nikolai; Hentschel, Mario; Zgrabik, Christine M; Metzger, Bernd; Linnenbank, Heiko; Hu, Evelyn L; Giessen, Harald

    2016-09-14

    Titanium nitride (TiN) is a novel refractory plasmonic material which can sustain high temperatures and exhibits large optical nonlinearities, potentially opening the door for high-power nonlinear plasmonic applications. We fabricate TiN nanoantenna arrays with plasmonic resonances tunable in the range of about 950-1050 nm by changing the antenna length. We present second-harmonic (SH) spectroscopy of TiN nanoantenna arrays, which is analyzed using a nonlinear oscillator model with a wavelength-dependent second-order response from the material itself. Furthermore, characterization of the robustness upon strong laser illumination confirms that the TiN antennas are able to endure laser irradiation with high peak intensity up to 15 GW/cm(2) without changing their optical properties and their physical appearance. They outperform gold antennas by one order of magnitude regarding laser power sustainability. Thus, TiN nanoantennas could serve as promising candidates for high-power/high-temperature applications such as coherent nonlinear converters and local heat sources on the nanoscale.

  12. Nanomaterial Case Studies: Nanoscale Titanium Dioxide ...

    Science.gov (United States)

    This draft document presents two case studies of nanoscale titanium dioxide (nano-TiO2) used (1) to remove arsenic from drinking water and (2) as an active ingredient in topical sunscreen. The draft case studies are organized around a comprehensive environmental assessment approach that combines a product life cycle framework with the risk assessment paradigm. The document does not draw conclusions about potential risks. Rather, the case studies are intended to help identify what needs to be known in order to conduct a comprehensive environmental assessment of the potential risks related to nano-TiO2. This draft document is part of a process that will inform the development of EPA’s research strategy to support nanomaterial risk assessments. The complex properties of various nanomaterials make evaluating them in the abstract or with generalizations difficult if not impossible. Thus, this document focuses on two specific uses of nano-TiO2, as a drinking water treatment and as topical sunscreen. These case studies do not represent completed or even preliminary assessments; rather, they present the structure for identifying and prioritizing research needed to support future assessments.

  13. Toxicology of nanosized titanium dioxide: an update.

    Science.gov (United States)

    Zhang, Xiaochen; Li, Wen; Yang, Zhuo

    2015-12-01

    Nanosized titanium dioxide (nano-TiO2) has tremendous potential for a host of applications, and TiO2 nanoparticles (NP) possess different physicochemical properties compared to their fine particle analogs, which might alter their bioactivity. Their adverse effects on living cells have raised serious concerns recently for their use in health care and consumer sectors such as sunscreens, cosmetics, pharmaceutical additives and implanted biomaterials. Many researches have demonstrated that the physicochemical properties including shape, size, surface characteristics and inner structure of nano-TiO2 particles have different degrees of toxicity to different organism groups under different conditions. Some former reports have demonstrated that nano-TiO2 materials could enter into human body through different routes such as inhalation, dermal penetration and ingestion. After being taken by human body, NP might induce oxidative stress, cytotoxicity, genotoxicity, inflammation and cell apoptosis ultimately in mammal organs and systems. Here, we summarized the update about toxicity of nano-TiO2 and aimed to supply a safety usage guideline of this nanomaterial.

  14. Characterization and stability studies of titanium beryllides

    Energy Technology Data Exchange (ETDEWEB)

    Alves, E. [Instituto Tecnologico e Nuclear, Departamento de Fisica, EN 10, 2686-953 Sacavem (Portugal) and CFNUL, University of Lisbon, Av. Prof. Gama Pinto 2, 1699 Lisbon (Portugal)]. E-mail: ealves@itn.pt; Alves, L.C. [Instituto Tecnologico e Nuclear, Departamento de Fisica, EN 10, 2686-953 Sacavem (Portugal); CFNUL, University of Lisbon, Av. Prof. Gama Pinto 2, 1699 Lisbon (Portugal); Franco, N. [Instituto Tecnologico e Nuclear, Departamento de Fisica, EN 10, 2686-953 Sacavem (Portugal); Silva, M.R. da [CFNUL, University of Lisbon, Av. Prof. Gama Pinto 2, 1699 Lisbon (Portugal); Paul, A. [Instituto de Ciencia de Materiales, Av. Americo Vespucio s/n, 41092 Sevilla (Portugal); Hegeman, J.B. [NRG, P.O. Box 25, 1755 ZG, Petten (Netherlands); Druyts, F. [SCK.CEN, The Belgian Nuclear Research Center, Boeretang 200, B-2400 Mol (Belgium)

    2005-11-15

    Beryllides appear as potential candidates to replace Be in future fusion power plants due to their improved properties. However, while the fabrication and properties of beryllium are well established a lack of knowledge still exists for beryllides. In this work, we present a detailed characterization of titanium beryllides, provided by JAERI in the frame of the IEA agreement, using a large number of techniques. Compositions of Be-5 at% Ti and Be-7 at% Ti were used to produce the samples. High resolution X-ray diffraction clearly shows the formation of Be{sub 1}Ti phase for the Be-7 at% Ti composition. For the Be-5 at% Ti, the major phase is Be{sub 12}Ti with traces of a Be-rich phase. In both cases, no evidence was found for the presence of pure Be phase in the samples. Ti elemental maps obtained with a scanning nuclear microprobe reveals the presence of regions containing large amounts of Cr, Mn, Fe, Ni, Cu and in some cases U. These impurities are common in Be and this behaviour suggests that a segregation process occurs during the beryllide formation. Moreover, the RBS spectra also show the presence of oxygen in this region while it seems to be depleted from the beryllide bulk. The oxidation seems to occur preferentially along the beryllide boundaries and Ti depleted region.

  15. Subcritical crack growth in two titanium alloys.

    Science.gov (United States)

    Williams, D. N.

    1973-01-01

    Measurement of subcritical crack growth during static loading of precracked titanium alloys in salt water using samples too thin for plane strain loading to predominate was examined as a method for determining the critical stress intensity for crack propagation in salt water. Significant internal crack growth followed by arrest was found at quite low stress intensities, but crack growth rates were relatively low. Assuming these techniques provided a reliable measurement of the critical stress intensity, the value for annealed Ti-4Al-1.5Mo-0.5V alloy was apparently about 35 ksi-in. to the 1/2 power, while that for annealed Ti-4Al-3Mo-1V was below 45 ksi-in. to the 1/2 power. Crack growth was also observed in tests conducted in both alloys in an air environment. At 65 ksi-in. to the 1/2 power, the extent of crack growth was greater in air than in salt water. Ti-4Al-3Mo-1V showed arrested crack growth in air at a stress intensity of 45 ksi-in. to the 1/2 power.

  16. Water vapor interactions with polycrystalline titanium surfaces

    Science.gov (United States)

    Azoulay, A.; Shamir, N.; Volterra, V.; Mintz, M. H.

    1999-02-01

    The initial interactions of water vapor with polycrystalline titanium surfaces were studied at room temperature. Measurements of water vapor surface accumulation were performed in a combined surface analysis system incorporating direct recoils spectrometry (DRS), Auger electron spectroscopy and X-ray photoelectron spectroscopy. The kinetics of accommodation of the water dissociation fragments (H, O and OH) displayed a complex behavior depending not only on the exposure dose but also on the exposure pressure. For a given exposure dose the efficiency of chemisorption increased with increasing exposure pressure. DRS measurements indicated the occurrence of clustered hydroxyl moieties with tilted O-H bonds formed even at very low surface coverage. A model which assumes two parallel routes of chemisorption, by direct collisions (Langmuir type) and by a precursor state is proposed to account for the observed behavior. The oxidation efficiency of water seemed to be much lower than that of oxygen. No Ti 4+ states were detected even at high water exposure values. It is likely that hydroxyl species play an important role in the reduced oxidation efficiency of water.

  17. Effect of electrolysis voltage on electrochemical reduction of titanium oxide to titanium in molten calcium chloride

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The electrochemical reduction of solid TiO2 directly to solid metal is a ptomising alternative to the current Kroll process. The present work is aimed at studying the effect of electrolysis voltage on the rate of electrochemical reduction. The products of electrochemical reduction of TiO2 and Ti2O were examined using the scanning electron microscopy (SEM) and X-ray diffraction (XRD) techniques. The results show that Ti2O was reduced to low valent titanium oxide at 1.5 -1.7 V, which was the result of ionization of oxygen. TiO2 and Ti2O were reduced to titanium metal at 2.1-3.1 V, which was the co-action of ionization of oxygen and calciothermic reduction. The oxygen content decreased rapidly with voltage increasing from 2.1 to 2.6 V, while it changed little from 2.6 to 3.1 V. The optimized cell voltage was 2.6-3.1 V.

  18. Titanium nitride deposition in titanium implant alloys produced by powder metallurgy

    Energy Technology Data Exchange (ETDEWEB)

    Henriques, V.A.R.; Cairo, C.A.A.; Faria, J., E-mail: vinicius@iae.cta.br, E-mail: ccairo@iae.cta.br, E-mail: juliacfaria@gmail.com [Instituto de Aeronautica e Espaco (AMR/CTA/IAE), Sao Jose dos Campos, SP (Brazil). Centro Tecnico Aeroespacial. Divisao de Materiais; Lemos, T.G., E-mail: tgorla@hotmail.com [Universidade de Sao Paulo (DEMAR/EEL/USP), Lorena, SP (Brazil). Escola de Engenharia; Galvani, E.T., E-mail: eduardotgalvani@yahoo.com.br [Instituto Tecnologico de Aeronautica (CTA/ITA), Sao Jose dos Campos, SP (Brazil). Centro Tecnico Aeroespacial

    2009-07-01

    Titanium nitride (TiN) is an extremely hard material, often used as a coating on titanium alloy, steel, carbide, and aluminum components to improve wear resistance. Electron Beam Physical Vapor Deposition (EB-PVD) is a form of deposition in which a target anode is bombarded with an electron beam given off by a charged tungsten filament under high vacuum, producing a thin film in a substrate. In this work are presented results of TiN deposition in targets and substrates of Ti (C.P.) and Ti-{sup 13}Nb-{sup 13}Zr obtained by powder metallurgy. Samples were produced by mixing of hydride metallic powders followed by uniaxial and cold isostatic pressing with subsequent densification by sintering between 900°C up to 1400 °C, in vacuum. The deposition was carried out under nitrogen atmosphere. Sintered samples were characterized for phase composition, microstructure and microhardness by X-ray diffraction, scanning electron microscopy and Vickers indentation, respectively. It was shown that the samples were sintered to high densities and presented homogeneous microstructure, with ideal characteristics for an adequate deposition and adherence. The film layer presented a continuous structure with 15μm. (author)

  19. Direct observation of titanium-centered octahedra in titanium-antimony-tellurium phase-change material.

    Science.gov (United States)

    Rao, Feng; Song, Zhitang; Cheng, Yan; Liu, Xiaosong; Xia, Mengjiao; Li, Wei; Ding, Keyuan; Feng, Xuefei; Zhu, Min; Feng, Songlin

    2015-11-27

    Phase-change memory based on Ti0.4Sb2Te3 material has one order of magnitude faster Set speed and as low as one-fifth of the Reset energy compared with the conventional Ge2Sb2Te5 based device. However, the phase-transition mechanism of the Ti0.4Sb2Te3 material remains inconclusive due to the lack of direct experimental evidence. Here we report a direct atom-by-atom chemical identification of titanium-centered octahedra in crystalline Ti0.4Sb2Te3 material with a state-of-the-art atomic mapping technology. Further, by using soft X-ray absorption spectroscopy and density function theory simulations, we identify in amorphous Ti0.4Sb2Te3 the titanium atoms preferably maintain the octahedral configuration. Our work may pave the way to more thorough understanding and tailoring of the nature of the Ti-Sb-Te material, for promoting the development of dynamic random access memory-like phase-change memory as an emerging storage-class memory to reform current memory hierarchy.

  20. Silicon-Doped Titanium Dioxide Nanotubes Promoted Bone Formation on Titanium Implants.

    Science.gov (United States)

    Zhao, Xijiang; Wang, Tao; Qian, Shi; Liu, Xuanyong; Sun, Junying; Li, Bin

    2016-02-26

    While titanium (Ti) implants have been extensively used in orthopaedic and dental applications, the intrinsic bioinertness of untreated Ti surface usually results in insufficient osseointegration irrespective of the excellent biocompatibility and mechanical properties of it. In this study, we prepared surface modified Ti substrates in which silicon (Si) was doped into the titanium dioxide (TiO₂) nanotubes on Ti surface using plasma immersion ion implantation (PIII) technology. Compared to TiO₂ nanotubes and Ti alone, Si-doped TiO₂ nanotubes significantly enhanced the expression of genes related to osteogenic differentiation, including Col-I, ALP, Runx2, OCN, and OPN, in mouse pre-osteoblastic MC3T3-E1 cells and deposition of mineral matrix. In vivo, the pull-out mechanical tests after two weeks of implantation in rat femur showed that Si-doped TiO₂ nanotubes improved implant fixation strength by 18% and 54% compared to TiO₂-NT and Ti implants, respectively. Together, findings from this study indicate that Si-doped TiO₂ nanotubes promoted the osteogenic differentiation of osteoblastic cells and improved bone-Ti integration. Therefore, they may have considerable potential for the bioactive surface modification of Ti implants.

  1. Study on interface between titanium-coated diamond and metal matrices

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The XRD spectrum of titanium-coated diamond showed the existence of titanium carbide on the interface between diamond and its titanium coating. The diffusions between titanium coating and metal matrices were studied by SEM. The SEM photographs revealed that titanium can interdiffuse with nickel, cobalt, copper,iron and copper-based alloy to a great extent to lead to the disappearance of pure titanium layer and the formation of titanium diffusion layer. The results from transverse-rupture strength test showed that titanium coating on diamond improved the bonding strength between diamond and metal matrices by 3.2% for Co-based segment and 4.1% for Cu-10Sn based segment respectively.

  2. Effect of Carburization on the Mechanical Properties of Biomedical Grade Titanium Alloys

    Institute of Scientific and Technical Information of China (English)

    Yong Luo; Haibo Jiang; Gang Cheng; Hongtao Liu

    2011-01-01

    Titanium cermets were successfully synthesized on the surface of biomedical grade titanium alloys by using sequential carburization method. The mechanical properties such as hardness, fracture toughness and plasticity were measured to estimate the potential application of titanium cermets. The results show that after carburization the surface hardness of titanium cermets was 778 HV, with a significant improvement of 128% compared with that of titanium alloys. In addition, the fracture toughness of titanium cermets was 21.5×106 Pa·m1/2, much higher than that of other ceramics. Furthermore, the analysis of the loading-unloading curve in the nanoindentation test also indicates that the plasticity of titanium cermet reached 32.1%, a relatively high value which illustrates the combination of the metal and ceramics properties. The results suggest that sequential carburization should be an efficient way to produce titanium cermets with hard surface, high toughness and plasticity.

  3. Recent research and development in titanium alloys for biomedical applications and healthcare goods

    Directory of Open Access Journals (Sweden)

    Mitsuo Niinomi

    2003-01-01

    Full Text Available Nb, Ta and Zr are the favorable non-toxic alloying elements for titanium alloys for biomedical applications. Low rigidity titanium alloys composed of non-toxic elements are getting much attention. The advantage of low rigidity titanium alloy for the healing of bone fracture and the remodeling of bone is successfully proved by fracture model made in tibia of rabbit. Ni-free super elastic and shape memory titanium alloys for biomedical applications are energetically developed. Titanium alloys for not only implants, but also dental products like crowns, dentures, etc. are also getting much attention in dentistry. Development of investment materials suitable for titanium alloys with high melting point is desired in dental precision castings. Bioactive surface modifications of titanium alloys for biomedical applications are very important for achieving further developed biocompatibility. Low cost titanium alloys for healthcare goods, like general wheel chairs, etc. has been recently proposed.

  4. Molecular and physiological responses to titanium dioxide and cerium oxide nanoparticles in arabidopsis

    Science.gov (United States)

    - Changes in tissue transcriptomes and productivity of Arabidopsis thaliana were investigated during exposure of plants to two widely-used engineered metal oxide nanoparticles, titanium dioxide (nano-titanium) and cerium dioxide (nano-cerium). Microarray analyses confirmed that e...

  5. Implants for surgery -- Metallic materials -- Part 3: Wrought titanium 6-aluminium 4-vanadium alloy

    CERN Document Server

    International Organization for Standardization. Geneva

    1996-01-01

    Specifies the characteristics of, and corresponding test methods for, the wrought titanium alloy known as titanium 6-aluminium 4-vanadium alloy (Ti 6-Al 4-V alloy) for use in the manufacture of surgical implants.

  6. Nanocrystalline hydroxyapatite/titania coatings on titanium improves osteoblast adhesion.

    Science.gov (United States)

    Sato, Michiko; Aslani, Arash; Sambito, Marisa A; Kalkhoran, Nader M; Slamovich, Elliott B; Webster, Thomas J

    2008-01-01

    Bulk hydroxyapatite (HA) and titania have been used to improve the osseointegration of orthopedic implants. For this reason, composites of HA and titania have been receiving increased attention in orthopedics as novel coating materials. The objective of this in vitro study was to produce nanophase (i.e., materials with grain size less than 100 nm) HA/titania coatings on titanium. The adhesion of bone forming cells (osteoblasts) on the composite coatings were also assessed and compared with single-phase nanotitania and nano-HA titanium coatings. Nanocrystalline HA powders were synthesized through wet chemistry and hydrothermal treatments at 200 degrees C. Nanocrystalline titania powders obtained commercially were mixed with the nanocrystalline HA powders at various weight ratios. The mixed powders were then deposited on titanium utilizing a room-temperature coating process called IonTite. The results of the present study showed that such coatings maintained the chemistry and crystallite size of the original HA and titania powders. Moreover, osteoblasts adherent on single-phase nanotitania coatings were well-spread whereas they became more round and extended distinct filopodia on the composite and single-phase HA coatings. Interestingly, the number of osteoblasts adherent on the nanotitania/HA composite coatings at weight ratios of 2/1 and 1/2 were significantly greater compared with single-phase nanotitania coatings, currently-used plasma-sprayed HA coatings, and uncoated titanium. These findings suggest that nanotitania/HA coatings on titanium should be further studied for improved orthopedic applications.

  7. Investigation of surface properties of high temperature nitrided titanium alloys

    Directory of Open Access Journals (Sweden)

    E. Koyuncu

    2009-12-01

    Full Text Available Purpose: The purpose of paper is to investigate surface properties of high temperature nitrided titanium alloys.Design/methodology/approach: In this study, surface modification of Ti6Al4V titanium alloy was made at various temperatures by plasma nitriding process. Plasma nitriding treatment was performed in 80% N2-20% H2 gas mixture, for treatment times of 2-15 h at the temperatures of 700-1000°C. Surface properties of plasma nitrided Ti6Al4V alloy were examined by metallographic inspection, X-Ray diffraction and Vickers hardness.Findings: Two layers were determined by optic inspection on the samples that were called the compound and diffusion layers. Compound layer contain TiN and Ti2N nitrides, XRD results support in this formations. Maximum hardness was obtained at 10h treatment time and 1000°C treatment temperature. Micro hardness tests showed that hardness properties of the nitrided samples depend on treatment time and temperature.Practical implications: Titanium and its alloys have very attractive properties for many industries. But using of titanium and its alloys is of very low in mechanical engineering applications because of poor tribological properties.Originality/value: The nitriding of titanium alloy surfaces using plasma processes has already reached the industrial application stage in the biomedical field.

  8. Degradation of titanium drillpipe from corrosion and wear

    Energy Technology Data Exchange (ETDEWEB)

    Ferg, T.E.; Aldrich, C.S. (Colorado School of Mines, Golden, CO (United States)); Craig, B.D. (Metallurgical Consultants Inc., Montebello (United States))

    1993-06-01

    Drilling deeper than 35,000 ft is limited by the extreme hook loads of steel drillpipe and temperature constraints of aluminum drillpipe. Titanium Alloys Ti-6Al-4V and Beta C have been proposed for use in drillpipe for wells deeper than 35,000 ft because of their high strength/weight ratios, superior high-temperature corrosion resistance, and thermal stability. Their suitability in drilling environments, however, has not been evaluated. To determine the corrosion and wear characteristics of two types of titanium-alloy drillpipe under dogleg conditions, a test cell was constructed to test titanium drillpipe joints in contact with API Spec. 5CT Grade P-110 casing in different drilling muds. Titanium-alloy pipe and Grade P-110 casing wear rates were measured, and tests showed that both titanium-alloy pipes exhibited much greater wear than did steel drillpipe in water-based mud under the same conditions. Test data showed that the total wear rate of Alloys Ti-6Al-4V and Beta C in a drilling environment is a combination of mechanical wear and corrosion.

  9. Toxicological characteristics of nanoparticulate anatase titanium dioxide in mice.

    Science.gov (United States)

    Duan, Yanmei; Liu, Jie; Ma, Linglan; Li, Na; Liu, Huiting; Wang, Jue; Zheng, Lei; Liu, Chao; Wang, Xuefeng; Zhao, Xiaoyang; Yan, Jingying; Wang, Sisi; Wang, Han; Zhang, Xueguang; Hong, Fashui

    2010-02-01

    In an effort to examine liver injury, immune response, and other physiological effects in mice caused by intragastric administration of nanoparticulate anatase titanium dioxide (5nm), we assessed T lymphocytes, B lymphocyte and NK lymphocyte counts, hematological indices, biochemical parameters of liver functions, and histopathological changes in nanoparticulate titanium dioxide -treated mice. Indeed, mice treated with higher dose nanoparticulate titanium dioxide displayed a reduction in body weight, an increase in coefficients of the liver and histopathological changes in the liver. Specifically, in these nanoparticulate titanium dioxide -treated mice, interleukin-2 activity, white blood cells, red blood cells, haemoglobin, mean corpuscular haemoglobin concentration, thrombocytes, reticulocytes, T lymphocytes (CD3(+), CD4(+), CD8(+)), NK lymphocytes, B lymphocytes, and the ratio of CD4 to CD8 of mice were decreased, whereas NO level, mean corpuscular volume, mean corpuscular haemoglobin, red (cell) distribution width, platelets, hematocrit, mean platelet volume of mice were increased. Furthermore, liver functions were also disrupted, as evidenced by the enhanced activities of alanine aminotransferase, alkaline phosphatase, aspartate aminotransferase, lactate dehydrogenase and cholinesterase, an increase of the total protein, and the reduction of ratio of albumin to globulin, the total bilirubin, triglycerides, and the total cholesterol levels. These results suggested that the liver function damage observed in mice treated with higher dose nanoparticulate titanium dioxide is likely associated with the damage of haemostasis blood system and immune response. However, low dose nanoparticulate anatase TiO(2) has little influences on haemostasis blood system and immune response in mice.

  10. Casting behavior of titanium alloys in a centrifugal casting machine.

    Science.gov (United States)

    Watanabe, K; Miyakawa, O; Takada, Y; Okuno, O; Okabe, T

    2003-05-01

    Since dental casting requires replication of complex shapes with great accuracy, this study examined how well some commercial titanium alloys and experimental titanium-copper alloys filled a mold cavity. The metals examined were three types of commercial dental titanium [commercially pure titanium (hereinafter noted as CP-Ti), Ti-6Al-4V (T64) and Ti-6Al-7Nb (T67)], and experimental titanium-copper alloys [3%, 5% and 10% Cu (mass %)]. The volume percentage filling the cavity was evaluated in castings prepared in a very thin perforated sheet pattern and cast in a centrifugal casting machine. The flow behavior of the molten metal was also examined using a so-called "tracer element technique." The amounts of CP-Ti and all the Ti-Cu alloys filling the cavity were similar; less T64 and T67 filled the cavity. However, the Ti-Cu alloys failed to reach the end of the cavities due to a lower fluidity compared to the other metals. A mold prepared with specially designed perforated sheets was effective at differentiating the flow behavior of the metals tested. The present technique also revealed that the more viscous Ti-Cu alloys with a wide freezing range failed to sequentially flow to the end of the cavity.

  11. BMP-2 and titanium particles synergistically activate osteoclast formation

    Energy Technology Data Exchange (ETDEWEB)

    Sun, S.X. [Affiliated Hospital of Ningxia Medical University, Department of Orthopedics, Yinchuan, Ningxia Hui Autonomous Region, China, Department of Orthopedics, Affiliated Hospital of Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region (China); Guo, H.H. [Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region, China, Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region (China); Zhang, J. [Institute of Pathology, Xi' an Jiaotong University, Xi' an Shaanxi, China, Institute of Pathology, Xi' an Jiaotong University, Xi' an Shaanxi (China); Yu, B. [Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region, China, Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region (China); Sun, K.N.; Jin, Q.H. [Affiliated Hospital of Ningxia Medical University, Department of Orthopedics, Yinchuan, Ningxia Hui Autonomous Region, China, Department of Orthopedics, Affiliated Hospital of Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region (China)

    2014-05-09

    A previous study showed that BMP-2 (bone morphogenetic protein-2) and wear debris can separately support osteoclast formation induced by the receptor activator of NF-κB ligand (RANKL). However, the effect of BMP-2 on wear debris-induced osteoclast formation is unclear. In this study, we show that neither titanium particles nor BMP-2 can induce osteoclast formation in RAW 264.7 mouse leukemic monocyte macrophage cells but that BMP-2 synergizes with titanium particles to enhance osteoclast formation in the presence of RANKL, and that at a low concentration, BMP-2 has an optimal effect to stimulate the size and number of multinuclear osteoclasts, expression of osteoclast genes, and resorption area. Our data also clarify that the effects caused by the increase in BMP-2 on phosphorylated SMAD levels such as c-Fos expression increased throughout the early stages of osteoclastogenesis. BMP-2 and titanium particles stimulate the expression of p-JNK, p-P38, p-IkB, and P50 compared with the titanium group. These data suggested that BMP-2 may be a crucial factor in titanium particle-mediated osteoclast formation.

  12. Preparation of calcium carbonate particles coated with titanium dioxide

    Institute of Scientific and Technical Information of China (English)

    Hai Lin; Ying-bo Dong; Le-yong Jiang

    2009-01-01

    The preparation of a new mineral composite material, calcium carbonate particles coated with titanium dioxide, was stud-ied. The mechanism of the preparation process was proposed. The new mineral composite material was made by the mechanochemi-eal method under the optimum condition that the mass ratio of calcium carbonate particles to titanium dioxide was 6.5:3.5. The mass ratios of two different types of titanium dioxide (anatase to rutile) and grinding media to grinded materials were 8:2 and 4:1 respec-tively, and the modified density was 60%. Under this condition, the new material was capable of forming after 120-min modification.The hiding power and oil absorption of this new material were 29.12 g/m~2 and 23.30%, respectively. The results show that the modi-fication is based on surface hydroxylation. After coating with titanium dioxide, the hiding power of calcium carbonate can be im-proved greatly. The new mineral composite materials can be used as the substitute for titanium dioxide.

  13. Biocorrosion and uptake of titanium by human osteoclasts.

    Science.gov (United States)

    Cadosch, Dieter; Al-Mushaiqri, Mohamed S; Gautschi, Oliver P; Meagher, James; Simmen, Hans-Peter; Filgueira, Luis

    2010-12-15

    All metals in contact with a biological system undergo corrosion through an electrochemical redox reaction. This study investigated whether human osteoclasts (OC) are able to grow on titanium and aluminum, and directly corrode the metals leading to the release of corresponding metal ions, which are believed to cause inflammatory reactions and activate osteoclastic differentiation. Scanning electron microscopy analysis demonstrated long-term viable OC cultures on the surface of titanium and aluminum foils. Atomic emission spectrometry investigations showed significantly increased levels of aluminum in the supernatant of OC cultured on aluminum; however, all measurements in the supernatants of cell cultures on titanium were below detection limits. Despite this, confocal microscopy analysis with Newport Green DCF diacetate ester staining depicted intense fluorescence throughout the cytoplasm and nucleolus of OC cultured on titanium foils. Comparable fluorescence intensities were not observed in monocytes and control cells cultured on glass. The present study demonstrated that human osteoclast precursors are able to grow and differentiate toward mature OC on titanium and aluminum. Furthermore, it established that the mature cells are able to directly corrode the metal surface and take up corresponding metal ions, which subsequently may be released and thereby induce the formation of osteolytic lesions in the periprosthetic bone, contributing to the loosening of the implant.

  14. Titanium recycling in the United States in 2004, chap. Y of Sibley, S.F., ed., Flow studies for recycling metal commodities in the United States

    Science.gov (United States)

    Goonan, Thomas G.

    2010-01-01

    As one of a series of reports that describe the recycling of metal commodities in the United States, this report discusses the titanium metal fraction of the titanium economy, which generates and uses titanium metal scrap in its operations. Data for 2004 were selected to demonstrate the titanium flows associated with these operations. This report includes a description of titanium metal supply and demand in the United States to illustrate the extent of titanium recycling and to identify recycling trends. In 2004, U.S. apparent consumption of titanium metal (contained in various titanium-bearing products) was 45,000 metric tons (t) of titanium, which was distributed as follows: 25,000 t of titanium recovered as new scrap, 9,000 t of titanium as titanium metal and titanium alloy products delivered to the U.S. titanium products reservoir, 7,000 t of titanium consumed by steelmaking and other industries, and 4,000 t of titanium contained in unwrought and wrought products exported. Titanium recycling is concentrated within the titanium metals sector of the total titanium market. The titanium market is otherwise dominated by pigment (titanium oxide) products, which generate dissipative losses instead of recyclable scrap. In 2004, scrap (predominantly new scrap) was the source of roughly 54 percent of the titanium metal content of U.S.-produced titanium metal products.

  15. Synthesis of bio-active titanium oxide coatings stimulated by electron-beam plasma

    Directory of Open Access Journals (Sweden)

    Vasilieva Tatiana

    2014-11-01

    Full Text Available Advantages of the electron-beam plasma (EBP for production of bioactive titanium oxide coatings were experimentally studied. The coatings were synthesized in EBP of oxygen on the surface of plane titanium substrates. A number of analytical techniques were used to characterize morphology, chemical composition, and structure of the synthesized titanium oxide. The analysis showed the titanium oxide (IV in the rutile form to predominate in the coatings composition.

  16. 40 CFR 440.50 - Applicability; description of the titanium ore subcategory.

    Science.gov (United States)

    2010-07-01

    ... titanium ore subcategory. 440.50 Section 440.50 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORE MINING AND DRESSING POINT SOURCE CATEGORY Titanium Ore Subcategory § 440.50 Applicability; description of the titanium ore subcategory. The provisions of...

  17. 40 CFR 415.220 - Applicability; description of the titanium dioxide production subcategory.

    Science.gov (United States)

    2010-07-01

    ... titanium dioxide production subcategory. 415.220 Section 415.220 Protection of Environment ENVIRONMENTAL... SOURCE CATEGORY Titanium Dioxide Production Subcategory § 415.220 Applicability; description of the titanium dioxide production subcategory. This subpart applies to discharges to waters of the United...

  18. Carbon-coated rutile titanium dioxide derived from titanium-metal organic framework with enhanced sodium storage behavior

    Science.gov (United States)

    Zou, Guoqiang; Chen, Jun; Zhang, Yan; Wang, Chao; Huang, Zhaodong; Li, Simin; Liao, Hanxiao; Wang, Jufeng; Ji, Xiaobo

    2016-09-01

    Carbon-coated rutile titanium dioxide (CRT) was fabricated through an in-situ pyrolysis of titanium-based metal organic framework (Ti8O8(OH)4[O2CC6H4CO2]6) crystals. Benefiting from the Tisbnd Osbnd C skeleton structure of titanium-based metal organic framework, the CRT possesses abundant channels and micro/mesopores with the diameters ranging from 1.06 to 4.14 nm, shows larger specific surface area (245 m2 g-1) and better electronic conductivity compared with pure titanium dioxide (12.8 m2 g-1). When applied as anode material for sodium-ion batteries, the CRT electrode exhibits a high cycling performance with a reversible capacity of ∼175 mAh g-1 at 0.5 C-rate after 200 cycles, and obtains an excellent rate capability of ∼70 mAh g-1 after 2000 cycles even at a specific current of 3360 mA g-1(20 C-rate). The outstanding rate capability can be attributed to the carbon-coated structure, which may effectively prevent aggregation of the titanium dioxide nanoparticles, accelerate the mass transfer of Na+ and speed up the charge transfer rate. Considering these advantages of this particular framework structure, the CRT can serve as an alternative anode material for the industrial application of SIBs.

  19. Discoloration and dissolution of titanium and titanium alloys with immersion in peroxide- or fluoride-containing solutions.

    Science.gov (United States)

    Noguchi, Tatsumi; Takemoto, Shinji; Hattori, Masayuki; Yoshinari, Masao; Kawada, Eiji; Oda, Yutaka

    2008-01-01

    This study compared differences in discoloration and dissolution in several titanium alloys with immersion in peroxide- or fluoride-containing solution. Commercially pure titanium (CP-Ti) and six titanium-based alloys were used: Ti-0.15Pd, Ti-6Al-4V, Ti-7Nb-6Al, Ti-55Ni, Ti-10Cu, and Ti-20Cr. Two test solutions were prepared for immersion of polished titanium and titanium alloys: one consisting of 0.2% NaF + 0.9% NaCl (pH 3.8 with lactic acid) and the other of 0.1 mol/l H2O2 + 0.9% NaCl (pH 5.5). Following immersion, color changes were determined with a color meter and released elements were measured using ICP-OES. Discoloration and dissolution rates differed between the two solutions. In the hydrogen peroxide-containing solution, color difference was higher in Ti-55Ni and Ti-6Al-4V than in any of the other alloys, and that Ti-55Ni showed the highest degree of dissolution. In the acidulated fluoride-containing solution, CP-Ti, Ti-0.15Pd, Ti-6Al-4V, Ti-7Nb-6Al, and Ti-10Cu alloys showed remarkable discoloration and dissolution with immersion. On the contrary, Ti-20Cr alloy showed very little discoloration and dissolution in either solution.

  20. Molecular Dynamics Simulations of Helium Behaviour in Titanium Crystals

    Institute of Scientific and Technical Information of China (English)

    SUN Tie-Ying; LONG Xing-Gui; WANG Jun; HOU Qing; WU Zhong-Cheng; PENG Shu-Ming; LUO Shun-Zhong

    2008-01-01

    Molecular dynamics simulations are performed to investigate the behaviour of helium atoms in titanium at a temperature of 300 K.The nucleation and growth of helium bubble has been simulated up to 50 helium atoms.The approach to simulate the bubble growth is to add helium atoms one by one to the bubble and let the system evolve.The titanium cohesion is based on the tight binding scheme derived from the embedded atom method,and the helium-titanium interaction is characterized by fitted potential in the form of a Lennard-Jones function.The pressure in small helium bubbles is approximately calculated.The simulation results show that the pressure will decrease with the increasing bubble size,while increase with the increasing helium atoms.An analytic function about the quantitative relationship of the pressure with the bubble size and number of helium atoms is also fitted.

  1. Comminuted Frontal Sinus Fracture Reconstructed With Titanium Mesh.

    Science.gov (United States)

    Sakat, Muhammed Sedat; Kilic, Korhan; Altas, Enver; Gozeler, Mustafa Sitki; Ucuncu, Harun

    2016-03-01

    Frontal sinus fractures (FSF) are relatively uncommon maxillofacial injuries. The most common cause of FSF is motor vehicle accidents with 62% percentage. Management of FSF depends on type of fracture, associated injuries, and involvement of naso-frontal duct. In this report, the authors presented a patient with comminuted fracture of anterior wall of frontal sinus reconstructed with titanium mesh. A 40-year-old man presented with depression of the frontal bone, facial pain, and epistaxis consisting of a motor vehicle accident. Computerized tomography scan revealed multiple comminuted fractures of anterior wall of frontal sinus and fractures of left orbital medial and superior walls. Titanium mesh was used for reconstruction. Postoperative course was uneventful. The titanium mesh, which is easy to handle with no complications, may provide excellent frontal contour after comminuted anterior wall fractures.

  2. Preparation and properties of biomedical porous titanium alloys by gelcasting.

    Science.gov (United States)

    Yang, Donghua; Shao, Huiping; Guo, Zhimeng; Lin, Tao; Fan, Lianpeng

    2011-08-01

    Porous titanium alloys have been prepared by gelcasting in this study. The elastic solid green body was first polymerized and then vacuum sintered to porous titanium alloys with low contamination by controlling sintering conditions. The microstructure and the total porosity of the vacuum sintered porous Ti-Co and Ti-Mo alloys were analyzed by using scanning electron microscopy and x-ray diffraction. Moreover, compression and bending tests were conducted to investigate their mechanical properties. The results show that open and closed three-dimensional pore morphologies and total porosity ranging from 38.34% to 58.32% can be achieved. In contrast to porous Ti by gelcasting, the compression and bending strengths of porous titanium alloys were significantly increased by adding Mo and Co with Young's modulus ranging between 7-25 GPa, which is close to that of human cortical bone, therefore being suited for potential application in load-bearing implants.

  3. Titanium Alloys and Processing for High Speed Aircraft

    Science.gov (United States)

    Brewer, William D.; Bird, R. Keith; Wallace, Terryl A.

    1996-01-01

    Commercially available titanium alloys as well as emerging titanium alloys with limited or no production experience are being considered for a variety of applications to high speed commercial aircraft structures. A number of government and industry programs are underway to improve the performance of promising alloys by chemistry and/or processing modifications and to identify appropriate alloys and processes for specific aircraft structural applications. This paper discusses some of the results on the effects of heat treatment, service temperatures from - 54 C to +177 C, and selected processing on the mechanical properties of several candidate beta and alpha-beta titanium alloys. Included are beta alloys Timetal 21S, LCB, Beta C, Beta CEZ, and Ti-10-2-3 and alpha-beta alloys Ti-62222, Ti-6242S, Timetal 550, Ti-62S, SP-700, and Corona-X. The emphasis is on properties of rolled sheet product form and on the superplastic properties and processing of the materials.

  4. Osteoblastic response to pectin nanocoating on titanium surfaces

    DEFF Research Database (Denmark)

    Gurzawska, Katarzyna; Svava, Rikke; Yihua, Yu

    2014-01-01

    Osseointegration of titanium implants can be improved by organic and inorganic nanocoating of the surface. The aim of our study was to evaluate the effect of organic nanocoating of titanium surface with unmodified and modified pectin Rhamnogalacturonan-Is (RG-Is) isolated from potato and apple...... viability, bone matrix formation and mineralization was tested using SaOS-2 cells. Nanocoating with pectin RG-Is affected surface properties and in consequence changed the environment for cellular response. The cells cultured on surfaces coated with RG-Is from potato with high content of linear 1.4-linked...... galactose produced higher level of mineralized matrix compared with control surfaces and surfaces coated with RG-I with low content of linear 1.4-linked galactose. The study showed that the pectin RG-Is nanocoating not only changed chemical and physical titanium surface properties, but also specific coating...

  5. Corrosion Behavior of Titanium in Artificial Saliva by Lactic Acid

    Directory of Open Access Journals (Sweden)

    Qing Qu

    2014-07-01

    Full Text Available As one of the main products produced by oral microorganisms, the role of lactic acid in the corrosion of titanium is very important. In this study, the corrosion behavior of titanium in artificial saliva with and without lactic acid were investigated by open-circuit potentials (OCPs, polarization curves and electrochemical impedance spectroscopy (EIS. OCP firstly increased with the amount of lactic acid from 0 to 3.2 g/L and then tended to decrease from 3.2 to 5.0 g/L. The corrosion of titanium was distinctly affected by lactic acid, and the corrosion rate increased with increasing the amount of lactic acid. At each concentration of lactic acid, the corrosion rate clearly increased with increasing the immersing time. Results of scanning electron microscopy (SEM also indicated that lactic acid accelerated the pitting corrosion in artificial saliva. A probable mechanism was also proposed to explain the experimental results.

  6. An Oxygen-Permeation Treatment for Hardening Titanium Alloys

    Institute of Scientific and Technical Information of China (English)

    MA Hong-yan; WANG Mao-cai; WEI Zheng; XIN Gong-chun

    2004-01-01

    In this paper, the characterization of oxygen permeation (OP) in titanium alloy TC11 at high temperature and the influence of oxygen solution layer on performances of substrate were characterized with the help of apparatus, such as TGA,SEM/EDAX, XRD, EPMA, Micro-hardness Tester, Two-body Abrasion Tester, Amsler Wear Test Machine, Potentiostat/Galvanostat Model 273 system. The results showed that there was a little shift in X-ray diffraction peaks of α and β phase during the OPT process as a result of oxygen solution. The OP treatment can significantly increase the surface hardness of titanium alloys and, accordingly, the abrasive wear resistance was improved. Titanium alloys with oxygen solution layer exhibited improved corrosion resistance both in 3.5 % NaCl and in 5 % HCl solution. Oxidation resistance of TC11 with oxygen solution layer at high temperature was also enhanced. The solution and hardening mechanisms were discussed based on the experimental results.

  7. Potential of rapid heat treatment of titanium alloys and steels

    Energy Technology Data Exchange (ETDEWEB)

    Ivasishin, O.M.; Teliovich, R.V. [Institute of Metal Physics, Kiev (Ukraine)

    1999-05-15

    Rapid heat treatment (RHT) of titanium alloys and steels, which includes rapid heating into the single-phase field, {beta} and {gamma} of titanium alloys and steels, respectively, is reviewed. Heating rate is an important parameter that affects the mechanism and kinetics of phase and/or structural transformation. Refinement of grain structure, formation of micro-chemical inhomogeneity and substructure in the high temperature phase following RHT are addressed. Thermo-kinetic effects during rapid heating of material with an initial metastable (quenched or deformed) microstructure are discussed. The response of titanium alloys and steels to RHT is compared. The improvement in mechanical properties of both material system following RHT is also presented. (orig.) 48 refs.

  8. Thin-film diffusion brazing of titanium alloys

    Science.gov (United States)

    Mikus, E. B.

    1972-01-01

    A thin film diffusion brazing technique for joining titanium alloys by use of a Cu intermediate is described. The method has been characterized in terms of static and dynamic mechanical properties on Ti-6Al-4V alloy. These include tensile, fracture toughness, stress corrosion, shear, corrosion fatigue, mechanical fatigue and acoustic fatigue. Most of the properties of titanium joints formed by thin film diffusion brazing are equal or exceed base metal properties. The advantages of thin film diffusion brazing over solid state diffusion bonding and brazing with conventional braze alloys are discussed. The producibility advantages of this process over others provide the potential for producing high efficiency joints in structural components of titanium alloys for the minimum cost.

  9. Production of nano-ceramic coatings on titanium implants

    Science.gov (United States)

    Fomin, A. A.; Rodionov, I. V.; Fomina, M. A.; Petrova, N. V.

    2015-03-01

    Composite titania coatings modified with hydroxyapatite nanoparticles were obtained on intraosseous implants fabricated from commercially pure titanium and titanium alloy Ti-2.5Al-5Mo-5V. The present study aims to identify consistency changes of morphological characteristics and physico-mechanical properties of titanium items coatings obtained by oxidation during induction heat treatment and modification with colloidal hydroxyapatite nanoparticles. The influence of temperature between 600 and 1200 °C and duration of thermal modification from 1 to 300 s was studied. It was established that high hardness about 6.7±1.9 GPa for nanocrystalline TiO2 coatings and 19.2±0.6 GPa for nanoceramic "TiO2+HAp" coatings is reached at 1000 °C and 120 s.

  10. Mucin secretion induced by titanium dioxide nanoparticles.

    Directory of Open Access Journals (Sweden)

    Eric Y T Chen

    Full Text Available Nanoparticle (NP exposure has been closely associated with the exacerbation and pathophysiology of many respiratory diseases such as Chronic Obstructive Pulmonary Disease (COPD and asthma. Mucus hypersecretion and accumulation in the airway are major clinical manifestations commonly found in these diseases. Among a broad spectrum of NPs, titanium dioxide (TiO(2, one of the PM10 components, is widely utilized in the nanoindustry for manufacturing and processing of various commercial products. Although TiO(2 NPs have been shown to induce cellular nanotoxicity and emphysema-like symptoms, whether TiO(2 NPs can directly induce mucus secretion from airway cells is currently unknown. Herein, we showed that TiO(2 NPs (<75 nm can directly stimulate mucin secretion from human bronchial ChaGo-K1 epithelial cells via a Ca(2+ signaling mediated pathway. The amount of mucin secreted was quantified with enzyme-linked lectin assay (ELLA. The corresponding changes in cytosolic Ca(2+ concentration were monitored with Rhod-2, a fluorescent Ca(2+ dye. We found that TiO(2 NP-evoked mucin secretion was a function of increasing intracellular Ca(2+ concentration resulting from an extracellular Ca(2+ influx via membrane Ca(2+ channels and cytosolic ER Ca(2+ release. The calcium-induced calcium release (CICR mechanism played a major role in further amplifying the intracellular Ca(2+ signal and in sustaining a cytosolic Ca(2+ increase. This study provides a potential mechanistic link between airborne NPs and the pathoetiology of pulmonary diseases involving mucus hypersecretion.

  11. A Novel Surface Treatment for Titanium Alloys

    Science.gov (United States)

    Lowther, S. E.; Park, C.; SaintClair, T. L.

    2004-01-01

    High-speed commercial aircraft require a surface treatment for titanium (Ti) alloy that is both environmentally safe and durable under the conditions of supersonic flight. A number of pretreatment procedures for Ti alloy requiring multi-stages have been developed to produce a stable surface. Among the stages are, degreasing, mechanical abrasion, chemical etching, and electrochemical anodizing. These treatments exhibit significant variations in their long-term stability, and the benefits of each step in these processes still remain unclear. In addition, chromium compounds are often used in many chemical treatments and these materials are detrimental to the environment. Recently, a chromium-free surface treatment for Ti alloy has been reported, though not designed for high temperature applications. In the present study, a simple surface treatment process developed at NASA/LaRC is reported, offering a high performance surface for a variety of applications. This novel surface treatment for Ti alloy is conventionally achieved by forming oxides on the surface with a two-step chemical process without mechanical abrasion. This acid-followed-by-base treatment was designed to be cost effective and relatively safe to use in a commercial application. In addition, it is chromium-free, and has been successfully used with a sol-gel coating to afford a strong adhesive bond after exposure to hot-wet environments. Phenylethynyl containing adhesives were used to evaluate this surface treatment with sol-gel solutions made of novel imide silanes developed at NASA/LaRC. Oxide layers developed by this process were controlled by immersion time and temperature and solution concentration. The morphology and chemical composition of the oxide layers were investigated using scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and Auger electron spectroscopy (AES). Bond strengths made with this new treatment were evaluated using single lap shear tests.

  12. Comparison of postoperative curative effect and the possible survival rate of prosthesis following cemented and cementless total hip replacement%人工全髋关节置换骨水泥和无骨水泥假体术后疗效及假体可能的生存率比较

    Institute of Scientific and Technical Information of China (English)

    张勇; 杨彤涛; 周勇; 马保安

    2006-01-01

    ,假体都没有达到理想固定的效果.假体类型的选择并不影响假体的寿命,要根据患者的年龄及是否还要行翻修术来决定假体类型;骨溶解与患者年龄、性别、假体类型无关.%BACKGROUND: Patients who suffered total hip replacement are most concerned about the survivorship of prosthesis. OBJECTIVE: To evaluate the postoperative curative effect following ce mented and cementless THR with a retrospective method, so as to provide experience for prolonging the survivoship of prosthesis. DESIGN: Randomized and controlled observation. SETTING: General Center of Orthopaedic Department, General Institute of Bone Oncology, Tangdu Hospital, Fourth Military Medical University of Chinese PLA. PARTICIPANTS: We admitted 356 patients who underwent THR from Department of Orthopaedics, Tangdu Hospital, Fourth Military Medical U niversity of Chinese PLA between March 1993 and March 2004. Among them, 298 were contacted and 105 (108 hips) followed up. The patients participated in the review voluntarily. They were of either gender and had different types of prosthesis. Prosthesis made in China was adopted before 2000 and prosthesis made in American STRIKER company after 2000: Prosthesis made in China was made of home-made bone cement; Prosthesis bone cement (import) was provided by American STRIKER prosthesis company. Home-made bone cement and import have the same components. Barium was added in both bone cement . The whole operation was con ducted by the physicians who worked in the artificial joint department after examination. METHODS: According to informal discussion summary about total hip replacement of Chinese Journal of Surgery in 1982 and Evaluation Scale of Mayo Total Hip Replacement Curative Effect, we designed follow-up table by ourselves. Totally 105 (108 hips) patients were followed up, among them, 62 (63 hips) were in the cemented group, 43 (45 hips) in the ce mentless group. Pain, function and motion range of the patients and

  13. Deposition of silver nanoparticles on titanium surface for antibacterial effect

    Directory of Open Access Journals (Sweden)

    Liao Juan

    2010-04-01

    Full Text Available Liao Juan1, Zhu Zhimin3, Mo Anchun1,2, Li Lei1, Zhang Jingchao11State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041, PR China; 2Department of Dental Implant, West China Stomatology Hospital, Sichuan University, Chengdu 610041, PR China; 3Department of Prosthodontics, West China Stomatology Hospital, Sichuan University, Chengdu 610041, PR ChinaAbstract: Microbial colonization on implanted devices and biofilm formation is a recurrent complication in implant surgery and may result in loss of implants. The aim of this study was to deposit silver nanoparticles on a titanium surface to obtain antibacterial properties. In the present study, we prepared a silver nanoparticle-modified titanium (Ti-nAg surface using silanization method. The morphology and chemical components of the Ti-nAg surface were characterized by scanning electron microscopy (SEM equipped with energy-dispersive spectroscopy (EDS. Two species of bacteria, Staphylococcus aureus and Escherichia coli, were utilized to test the antibacterial effect of the Ti-nAg treated surface. The SEM examination revealed that a small quantity of silver nanoparticles was sparsely deposited on the titanium surface. The diameter of these nanoparticles ranged from ten to several hundred nm. EDS analyses revealed that there was 4.26% of Ag present on the surface. After a 24-hour incubation, 94% of Staphylococcus aureus and over 95% of Escherichia coli had been killed on the Ti-nAg surface, and the SEM examination of anti-adhesive efficacy test showed that there were less bacteria attached to Ti-nAg surface than to a control surface of untreated Titanium. These data suggest that silver nanoparticle-modified titanium is a promising material with an antibacterial property that may be used as an implantable biomaterial.Keywords: nano-silver, titanium, antibacterial activity, silanization method

  14. In vitro behaviour of endothelial cells on a titanium surface

    Directory of Open Access Journals (Sweden)

    Oliveira-Filho Ricardo

    2008-07-01

    Full Text Available Abstract Background Endothelial cells play an important role in the delivery of cells to the inflammation site, chemotaxis, cell adhesion and extravasation. Implantation of a foreign material into the human body determines inflammatory and repair reactions, involving different cell types with a plethora of released chemical mediators. The evaluation of the interaction of endothelial cells and implanted materials must take into account other parameters in addition to the analysis of maintenance of cell viability. Methods In the present investigation, we examined the behavior of human umbilical vein endothelial cells (HUVECs harvested on titanium (Ti, using histological and immunohistochemical methods. The cells, after two passages, were seeded in a standard density on commercially plate-shaped titanium pieces, and maintained for 1, 7 or 14 days. Results After 14 days, we could observe a confluent monolayer of endothelial cells (ECs on the titanium surface. Upon one-day Ti/cell contact the expression of fibronectin was predominantly cytoplasmatic and stronger than on the control surface. It was observed strong and uniform cell expression along the time of α5β1 integrin on the cells in contact with titanium. Conclusion The attachment of ECs on titanium was found to be related to cellular-derived fibronectin and the binding to its specific receptor, the α5β1 integrin. It was observed that titanium effectively serves as a suitable substrate for endothelial cell attachment, growth and proliferation. However, upon a 7-day contact with Ti, the Weibel-Palade bodies appeared to be not fully processed and exhibited an anomalous morphology, with corresponding alterations of PECAM-1 localization.

  15. Comparison of Titanium vs. Polycel Total Ossicular Replacement Prosthesis

    Directory of Open Access Journals (Sweden)

    Mohammad Faramarzi

    2016-01-01

    Full Text Available Introduction: Even though modern technology progresses so rapidly, annals of otology are replete with so many challenging article, which often compare various types of prosthesis. Since there has not been a prospective randomized clinical trial study which compares the hearing result of total ossicular replacement prosthesis made of Titanium with omega connector and Polycel in the literature, we decided to perform a study encompassing this issue.   Materials and Methods: 105 patients, who were in the 2nd stage of their operation and who needed total ossicular replacement prosthesis, were included in this prospective single blind randomized clinical trial study. Patients were classified in two groups: titanium Kurz (TTP™ -Vario system, Kurz GmbH, Dusslingen, Germany with omega connector and Polycel (Sheehy Plastipore Polycel, Medtronic Xomed Inc. The duration of the follow up was 6-12 months. In order to evaluate hearing results, pure tone audiometric in 0.5, 1, 2, and 4 kHz were checked. In addition, speech reception threshold was recorded. A successful surgery was defined as having a postoperative air–bone gap within 20 dB.   Results: We accomplished successful hearing in 64.4% of patients with titanium and 65% of patients with a Polycel prosthesis.Improvement in speech reception threshold was 11.5 dB in the titanium group and 13 dB in the Polycel group. In other words, there was no significant difference between the two groups. In addition, air-bone gap improvement after ossiculoplasty was 11.2 dB in the patients with a titanium prosthesis and 12.4 dB in the Polycel group. In fact, the difference was not significant.   Conclusion: We found that both the titanium and the Polycel prosthesis improve speech reception threshold and air-bone gap closure in a similar manner.

  16. Characterization of closed nickel-titanium orthodontic coil springs

    Energy Technology Data Exchange (ETDEWEB)

    Langeron, T. [Rene Descartes Univ., Paris V, Pontoise (France). Faculte de Chirurgie Dentaire; Filleul, M.P. [Rene Descartes Univ., Paris V, Pontoise (France). Faculte de Chirurgie Dentaire; ENSCP, Paris (France). Lab. de Metallurgie Structurale; Humbeeck, J. van [Katholieke Univ. Leuven, Heverlee (Belgium). Faculteit Toegepaste Wetenschappen, Metaalkunde en Toegepaste Materialkund

    2001-11-01

    Nickel-titanium orthodontic coil springs are used to move teeth with low forces and slow deactivation. The present paper provides data on transformation temperatures and on load-deflection rate at buccal temperature of closed Nickel-Titanium coil springs available on the market from ORMCO {sup trademark} and GAC {sup trademark}. All the springs exhibited superelasticity but their properties were not stable in the range of buccal temperatures and varied not only from one manufacturer to the other but they also varied from one batch to the other of each supplier. The need for more stability is stressed. (orig.)

  17. Formation of titanium carbide coating with micro-porous structure

    Science.gov (United States)

    Luo, Yong; Ge, Shirong; Jin, Zhongmin; Fisher, John

    2010-03-01

    Micro-porous titanium carbide coating was successfully synthesized in a vacuum gas carburizing furnace by using a sequential diffusion technology. The composition and structure of the as-synthesized TiC were examined by X-ray diffraction, X-ray photoelectron spectroscopy (XPS) and glow discharge mass spectrometry (GDMS), and scanning electron microscopy (SEM). All of the XRD, XPS and GDMS analysis results indicate that carbon atoms effectively diffused into the titanium alloys and formed a uniform acicular TiC coating with micro-porous structure.

  18. Handbook of International Alloy Compositions and Designations. Volume 1. Titanium

    Science.gov (United States)

    1976-11-01

    Germany. CC) OIN=Deutsche Normen (German Standards) (General form and composition specifications). CD) DIN=Deutsche Norman Werkstoffe Numbers...00 GY DIN 3.7040 draft 00/00 GY DIN 3.7070 draft 00/00 GY DIN 3.7115 12/73 12/73 00/00 03/70 00/00 03/70 Deutsche Normen (German Standard) for...titanium chemical compositions Deutsche Normen (German Standard) for wrought titanium alloys Deutsche Normen (German Standard) for plate, sheet

  19. Structural and magnetic properties of mechanochemically synthesized nanocrystalline titanium monoxide

    Directory of Open Access Journals (Sweden)

    Barudžija Tanja

    2012-01-01

    Full Text Available Nano-sized titanium monoxide (TiO powder was prepared by mechanochemical synthesis. A mixture of commercial Ti and TiO2 (rutile powders with the molar ratio of 1:1 was milled in a planetary ball mill for 5, 10, 20, 30 and 60 min under argon atmosphere. The final single-phase titanium monoxide sample was characterized by X-ray diffraction (XRD, magnetic measurements using a superconducting quantum interference device magnetometer (SQUID and thermogravimetric analysis (TGA. The temperature dependency of the magnetic susceptibility is characterized by significant contribution of Pauli paramagnetism due to conduction electrons.

  20. Photocatalytic Cementitious Composites containing Mesoporous Titanium Dioxide Nanoparticles

    Directory of Open Access Journals (Sweden)

    FALIKMAN Vyacheslav Ruvimovich

    2014-02-01

    Full Text Available The advanced method to produce nanoparticles of anatase mesoporous TiO₂ with high specific surface 300 m²/g has been developed. It was shown that titanium nanodioxide can be used in cement and gypsum composites as a highly efficient photocatalyst in the conversion processes of nitric oxide and volatile organic substances. Influence of radiation intensity, relative humidity, and concentration of contaminant and its stream speed on photocatalysis was studied. It was determined that efficiency of the composites with synthesized samples is 1,5–1,7 times higher than that of the commercial sample of the titanium nanodioxide.

  1. Hydrogen embrittlement and galvanic corrosion of titanium alloys

    Energy Technology Data Exchange (ETDEWEB)

    Soh, Jeong Ryong; Jeong, Y. H.; Choi, B. K.; Baek, J. H.; Hwang, D. Y.; Choi, B. S.; Lee, D. J

    2000-06-01

    The material properties including the fracture behavior of titanium alloys used as a steam generator tube in SMART can be degraded de to the hydrogen embrittlement and the galvanic corrosion occurring as a result of other materials in contact with titanium alloys in a conducting corrosive environment. In this report the general concepts and trends of hydrogen embrittlement are qualitatively described to adequately understand and expect the fracture behavior from hydrogen within the bulk of materials and under hydrogen containing environments because hydrogen embrittlement may be very complicated process. And the characteristics of galvanic corrosion closely related to hydrogen embrittlement is qualitatively based on wimple electrochemical theory.

  2. Design of 3D-Printed Titanium Compliant Mechanisms

    Science.gov (United States)

    Merriam, Ezekiel G.; Jones, Jonathan E.; Howell, Larry L.

    2014-01-01

    This paper describes 3D-printed titanium compliant mechanisms for aerospace applications. It is meant as a primer to help engineers design compliant, multi-axis, printed parts that exhibit high performance. Topics covered include brief introductions to both compliant mechanism design and 3D printing in titanium, material and geometry considerations for 3D printing, modeling techniques, and case studies of both successful and unsuccessful part geometries. Key findings include recommended flexure geometries, minimum thicknesses, and general design guidelines for compliant printed parts that may not be obvious to the first time designer.

  3. Effects of titanium and zirconium on iron aluminide weldments

    Energy Technology Data Exchange (ETDEWEB)

    Burt, R.P.; Edwards, G.R. [Colorado School of Mines, Golden, CO (United States); David, S.A. [Oak Ridge National Lab., TN (United States)

    1996-08-01

    Iron aluminides form a coarse fusion zone microstructure when gas-tungsten arc welded. This microstructure is susceptible to hydrogen cracking when water vapor is present in the welding environment. Because fusion zone microstructural refinement can reduce the hydrogen cracking susceptibility, titanium was used to inoculate the weld pool in iron aluminide alloy FA-129. Although the fusion zone microstructure was significantly refined by this method, the fracture stress was found to decrease with titanium additions. This decrease is attributed to an increase in inclusions at the grain boundaries.

  4. Experimental study of highly ionized spectra of titanium

    Institute of Scientific and Technical Information of China (English)

    YANG Zhihu; DU Shubin; SU Hong; ZHANG Yanping; REN Shouting; ZENG Xiantang

    2004-01-01

    The spectra of highly charged titanium ions produced by the interaction of 120 MeV titanium ions with carbon foil were investigated with the so-called beam-foil technique using the HI-13 tandem accelerator in China Institute of Atomic Energy. Spectral lines emitted from fifty- three excited energy levels were observed in the wavelength range 120-220(A), among which eleven lines were new. Our experimental results show good agreement with the results of laser plasma experiments, and are in reasonable agreement with theoretical calculations.

  5. Mechanical biocompatibilities of titanium alloys for biomedical applications.

    Science.gov (United States)

    Niinomi, Mitsuo

    2008-01-01

    Young's modulus as well as tensile strength, ductility, fatigue life, fretting fatigue life, wear properties, functionalities, etc., should be adjusted to levels that are suitable for structural biomaterials used in implants that replace hard tissue. These factors may be collectively referred to as mechanical biocompatibilities. In this paper, the following are described with regard to biomedical applications of titanium alloys: the Young's modulus, wear properties, notch fatigue strength, fatigue behaviour on relation to ageing treatment, improvement of fatigue strength, fatigue crack propagation resistance and ductility by the deformation-induced martensitic transformation of the unstable beta phase, and multifunctional deformation behaviours of titanium alloys.

  6. Titanium: the mystery metal of implant dentistry. Dental materials aspects.

    Science.gov (United States)

    Parr, G R; Gardner, L K; Toth, R W

    1985-09-01

    A number of important points concerning titanium and its alloys have been discussed. They are summarized as follows. Ti and its alloys, particularly the alpha-beta alloys, possess mechanical properties that make them ideal implant materials. Ti and its alloys oxidize readily in air. This surface oxide is extremely stable in the physiologic environment of the body. The stability and inertness of this surface oxide layer acts to protect Ti from corrosive breakdown when used in the body. The elimination of surface irregularities and contaminants is important when preparing a metal for implantation. Titanium can be coupled with equally passive metals in the body without causing galvanic corrosion.

  7. Narrow titanium oxide nanowires induced by femtosecond laser pulses on a titanium surface

    Science.gov (United States)

    Li, Hui; Li, Xian-Feng; Zhang, Cheng-Yun; Tie, Shao-Long; Lan, Sheng

    2017-02-01

    The evolution of the nanostructure induced on a titanium (Ti) surface with increasing irradiation pulse number by using a 400-nm femtosecond laser was examined by using scanning electron microscopy. High spatial frequency periodic structures of TiO2 parallel to the laser polarization were initially observed because of the laser-induced oxidation of the Ti surface and the larger efficacy factor of TiO2 in this direction. Periodically aligned TiO2 nanowires with featured width as small as 20 nm were obtained. With increasing pulse number, however, low spatial frequency periodic structures of Ti perpendicular to the laser polarization became dominant because Ti possesses a larger efficacy factor in this direction. The competition between the high- and low-spatial frequency periodic structures is in good agreement with the prediction of the efficacy factor theory and it should also be observed in the femtosecond laser ablation of other metals which are easily oxidized in air.

  8. Raman scattering in transition metal compounds: Titanium and compounds of titanium

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez, J.; Ederer, D.L.; Shu, T. [Tulane Univ., New Orleans, LA (United States)] [and others

    1997-04-01

    The transition metal compounds form a very interesting and important set of materials. The diversity arises from the many states of ionization the transition elements may take when forming compounds. This variety provides ample opportunity for a large class of materials to have a vast range of electronic and magnetic properties. The x-ray spectroscopy of the transition elements is especially interesting because they have unfilled d bands that are at the bottom of the conduction band with atomic like structure. This group embarked on the systematic study of transition metal sulfides and oxides. As an example of the type of spectra observed in some of these compounds they have chosen to showcase the L{sub II, III} emission and Raman scattering in some titanium compounds obtained by photon excitation.

  9. Titanium tritide radioisotope heat source development : palladium-coated titanium hydriding kinetics and tritium loading tests.

    Energy Technology Data Exchange (ETDEWEB)

    Van Blarigan, Peter; Shugard, Andrew D.; Walters, R. Tom (Savannah River National Labs, Aiken, SC)

    2012-01-01

    We have found that a 180 nm palladium coating enables titanium to be loaded with hydrogen isotopes without the typical 400-500 C vacuum activation step. The hydriding kinetics of Pd coated Ti can be described by the Mintz-Bloch adherent film model, where the rate of hydrogen absorption is controlled by diffusion through an adherent metal-hydride layer. Hydriding rate constants of Pd coated and vacuum activated Ti were found to be very similar. In addition, deuterium/tritium loading experiments were done on stacks of Pd coated Ti foil in a representative-size radioisotope heat source vessel. The experiments demonstrated that such a vessel could be loaded completely, at temperatures below 300 C, in less than 10 hours, using existing department-of-energy tritium handling infrastructure.

  10. Crystal structural and diffusion property in titanium carbides: A molecular dynamics study

    Science.gov (United States)

    Lv, Yanan; Gao, Weimin

    2016-09-01

    Titanium carbides were studied via molecular dynamics simulation to characterize TiCx structures with respect to the carbon diffusion properties in this study. The effect of carbon concentration on atomic structures of titanium carbides was investigated through discussing the structure variation and the radial distribution functions of carbon atoms in titanium carbides. The carbon diffusion in titanium carbides was also analyzed, focusing on the dependence on carbon concentration and carbide structure. Carbon diffusivity with different carbon concentrations was determined by molecular dynamics (MD) calculations and compared with the available experimental data. The simulation results showed an atomic exchange mechanism for carbon diffusion in titanium carbide.

  11. Increasing the active surface of titanium islands on graphene by nitrogen sputtering

    CERN Document Server

    Mashoff, T; Miseikis, V; Coletti, C; Piazza, V; Beltram, F; Heun, S

    2014-01-01

    Titanium-island formation on graphene as a function of defect density is investigated. When depositing titanium on pristine graphene, titanium atoms cluster and form islands with an average diameter of about 10nm and an average height of a few atomic layers. We show that if defects are introduced in the graphene by ion bombardment, the mobility of the deposited titanium atoms is reduced and the average diameter of the islands decreases to 5nm with monoatomic height. This results in an optimized coverage for hydrogen storage applications since the actual titanium surface available per unit graphene area is significantly increased.

  12. Electrochemical behavior of titanium in saline environments: The effects of temperature, pH, and microstructure

    Energy Technology Data Exchange (ETDEWEB)

    VanVliet, K.J.; Wang, Z.F.; Briant, C.L.; Kumar, K.S. [Brown Univ., Providence, RI (United States). Div. of Engineering

    1998-12-31

    This research investigates the effects of temperature, pH, degree of salinity, galvanic coupling, microstructure, and composition on the electrochemical behavior of commercially pure titanium in a saline environment. Essentially, the findings establish that increased temperature, altered microstructure, decreased pH, and decreased purity of titanium all serve to increase the corrosion potential and cathodic reaction rate, thus making the metal more susceptible to hydrogen absorption. Further, the data indicate that galvanic coupling with certain metals such as naval brass and stainless steel can anodically polarize titanium, whereas coupling with metals such as aluminum, HY80 steel, and zinc catholically polarizes titanium, thus promoting hydrogen evolution on the titanium surface.

  13. Investigation of the Surface Properties of Titanium Biomaterial with Oxide Layer of Rutile Structure

    Institute of Scientific and Technical Information of China (English)

    Huang Nan; Chen Yuanru; Xiao Jing; Xue Zhennan; Liu Xianghuai

    1994-01-01

    Structural characteristics of titanium oxide layer on titanium matrix were investigated by Rutherford Backscattering Spectroscopy (RBS), Auger Electron Spectroscopy(AES) and X-ray diffraction, It has been identified that the titanium oxide layers have rutile structure. The mechanical properties of its surface were ineasured by microhardness test, pin-on-disc wear experiment and scratch adhesion test. The blood-compatibility of the titanium oxide layers of different thickness was studied by blood clotting time measurement. It is shown that as the thickness of the titanium oxide layers increases, the surface mechanical properties and bloodcompatibility of these layers are obviously improved.

  14. Solid State Joining of Dissimilar Titanium Alloys

    Science.gov (United States)

    Morton, Todd W.

    Solid state joining of titanium via friction stir welding and diffusion bonding have emerged as enablers of efficient monolithic structural designs by the eliminations fasteners for the aerospace industry. As design complexity and service demands increase, the need for joints of dissimilar alloys has emerged. Complex thermomechanical conditions in friction stir weld joints and high temperature deformation behavior differences between alloys used in dissimilar joints gives rise to a highly variable flow pattern within a stir zone. Experiments performed welding Ti-6Al-4V to beta21S show that mechanical intermixing of the two alloys is the primary mechanism for the generation of the localized chemistry and microstructure, the magnitude of which can be directly related to pin rotation and travel speed weld parameters. Mechanical mixing of the two alloys is heavily influenced by strain rate softening phenomena, and can be used to manipulate weld nugget structure by switching which alloy is subjected to the advancing side of the pin. Turbulent mixing of a weld nugget and a significant reduction in defects and weld forces are observed when the beta21S is put on the advancing side of the weld where higher strain rates are present. Chemical diffusion driven by the heat of weld parameters is characterized using energy dispersive x-ray spectroscopy (EDS) and is shown to be a secondary process responsible for generating short-range chemical gradients that lead to a gradient of alpha particle structures. Diffusion calculations are inconsistent with an assumption of steady-state diffusion and show that material interfaces in the weld nugget evolve through the break-down of turbulent interface features generated by material flows. A high degree of recrystallization is seen throughout the welds, with unique, hybrid chemistry grains that are generated at material interfaces in the weld nugget that help to unify the crystal structure of dissimilar alloys. The degree of

  15. A Modified Porous Titanium Sheet Prepared by Plasma-Activated Sintering for Biomedical Applications

    Directory of Open Access Journals (Sweden)

    Yukimichi Tamaki

    2010-01-01

    Full Text Available This study aimed to develop a contamination-free porous titanium scaffold by a plasma-activated sintering within an originally developed TiN-coated graphite mold. The surface of porous titanium sheet with or without a coated graphite mold was characterized. The cell adhesion property of porous titanium sheet was also evaluated in this study. The peak of TiC was detected on the titanium sheet processed with the graphite mold without a TiN coating. Since the titanium fiber elements were directly in contact with the carbon graphite mold during processing, surface contamination was unavoidable event in this condition. The TiC peak was not detectable on the titanium sheet processed within the TiN-coated carbon graphite mold. This modified plasma-activated sintering with the TiN-coated graphite mold would be useful to fabricate a contamination-free titanium sheet. The number of adherent cells on the modified titanium sheet was greater than that of the bare titanium plate. Stress fiber formation and the extension of the cells were observed on the titanium sheets. This modified titanium sheet is expected to be a new tissue engineering material in orthopedic bone repair.

  16. Enhanced osteoblast adhesion to drug-coated anodized nanotubular titanium surfaces.

    Science.gov (United States)

    Eaninwene, George; Yao, Chang; Webster, Thomas J

    2008-01-01

    Current orthopedic implants have functional lifetimes of only 10-15 years due to a variety of reasons including infection, extensive inflammation, and overall poor osseointegration (or a lack of prolonged bonding of the implant to juxtaposed bone). To improve properties of titanium for orthopedic applications, this study anodized and subsequently coated titanium with drugs known to reduce infection (penicillin/streptomycin) and inflammation (dexamethasone) using simple physical adsorption and the deposition of such drugs from simulated body fluid (SBF). Results showed improved drug elution from anodized nanotubular titanium when drugs were coated in the presence of SBF for up to 3 days. For the first time, results also showed that the simple physical adsorption of both penicillin/streptomycin and dexamethasone on anodized nanotubular titanium improved osteoblast numbers after 2 days of culture compared to uncoated unanodized titanium. In addition, results showed that depositing such drugs in SBF on anodized titanium was a more efficient method to promote osteoblast numbers compared to physical adsorption for up to 2 days of culture. In addition, osteoblast numbers increased on anodized titanium coated with drugs in SBF for up to 2 days of culture compared to unanodized titanium. In summary, compared to unanodized titanium, this preliminary study provided unexpected evidence of greater osteoblast numbers on anodized titanium coated with either penicillin/streptomycin or dexamethasone using simple physical adsorption or when coated with SBF; results which suggest the need for further research on anodized titanium orthopedic implants possessing drug-eluting nanotubes.

  17. Titanium-Based Hip Stems with Drug Delivery Functionality through Additive Manufacturing.

    Science.gov (United States)

    Bezuidenhout, Martin B; Dimitrov, Dimitar M; van Staden, Anton D; Oosthuizen, Gert A; Dicks, Leon M T

    2015-01-01

    Postoperative infections are a major concern in patients that receive implants. These infections generally occur in areas with poor blood flow and pathogens do not always respond to antibiotic treatment. With the latest developments in nanotechnology, the incorporation of antibiotics into prosthetic implants may soon become a standard procedure. The success will, however, depend on the ability to control the release of antibiotics at concentrations high enough to prevent the development of antibiotic-resistant strains. Through additive manufacturing, antibiotics can be incorporated into cementless femoral stems to produce prosthetic devices with antimicrobial properties. With the emerging increase in resistance to antibiotics, the incorporation of antimicrobial compounds other than antibiotics, preferably drugs with a broader spectrum of antimicrobial activity, will have to be explored. This review highlights the microorganisms associated with total hip arthroplasty (THA), discusses the advantages and disadvantages of the latest materials used in hip implants, compares different antimicrobial agents that could be incorporated, and addresses novel ideas for future research.

  18. Effect of composition of titanium in silver-copper-titanium braze alloy on dissimilar laser brazing of binder-less cubic boron nitride and tungsten carbide

    Science.gov (United States)

    Sechi, Yoshihisa; Nagatsuka, Kimiaki; Nakata, Kazuhiro

    2014-08-01

    Laser brazing with Ti as an active element in silver-copper alloy braze metal has been carried out for binder-less cubic boron nitride and tungsten carbide, using silver-copper- titanium braze alloys with titanium content that varied between 0.28 mass% and 1.68 mass%. Observations of the interface using electron probe microanalysis and scanning acoustic microscopy show that efficient interface adhesion between binder-less cubic boron nitride and the silver-copper-titanium braze alloy was achieved for the braze with a titanium content of 0. 28 mass%.

  19. Friction and wear of titanium alloys and copper alloys sliding against titanium 6-percent-aluminum - 4-percent-vanadium alloy in air at 430 C

    Science.gov (United States)

    Wisander, D. W.

    1976-01-01

    Experiments were conducted to determine the friction and wear characteristics of aluminum bronzes and copper-tin, titanium-tin, and copper-silver alloys sliding against a titanium-6% aluminum-4% vanadium alloy (Ti-6Al-4V). Hemispherically tipped riders of aluminum bronze and the titanium and copper alloys were run against Ti-6Al-4V disks in air at 430 C. The sliding velocity was 13 cm/sec, and the load was 250 g. Results revealed that high tin content titanium and copper alloys underwent significantly less wear and galling than commonly used aluminum bronzes. Also friction force was less erratic than with the aluminum bronzes.

  20. Bioactive titanium metal surfaces with antimicrobial properties prepared by anodic oxidation treatment

    Institute of Scientific and Technical Information of China (English)

    YUE ChongXia; YANG BangCheng; ZHANG XingDong

    2009-01-01

    In order to endow titanium metals with bioactivity and antimicrobial properties,titanium plates were subjected to anodic oxidation treatment in NaCI solutions in this study.The treated titanium metals could induce apatite formation in the fast calcification solution,and osteoblasts on the treated titanium surfaces proliferated well as those on the untreated titanium metal surfaces.The treated metals could inhibit S.aureus growth in the microbial culture experiments.It was assumed that Ti-OH groups and Ti-CI groups formed on the treated titanium surface were responsible for the bioactivity and antimicrobial properties of the metals.The anodic oxidation treatment was an effective way to prepare bioactive titanium surfaces with antimicrobial properties.