WorldWideScience

Sample records for cementless highly-porous titanium

  1. Initial mechanical stability of cementless highly-porous titanium tibial components

    Energy Technology Data Exchange (ETDEWEB)

    Stone, Timothy Brandon [Los Alamos National Laboratory; Amer, Luke D [Los Alamos National Laboratory; Warren, Christopher P [Los Alamos National Laboratory; Cornwell, Phillip [Los Alamos National Laboratory; Meneghini, R Michael [UNIV OF CONNECTICUT HEALTH CENTER

    2008-01-01

    Cementless fixation in total knee replacement has seen limited use since reports of early failure surfaced in the late 80s and early 90s. However the emergence of improved biomaterials, particularly porous titanium and tantalum, has led to a renewed interest in developing a cementless tibial component to enhance long-term survivorship of the implants. Cement is commonly employed to minimize micromotion in new implants but represents a weak interface between the implant and bone. The elimination of cement and application of these new biomaterials, which theoretically provide improved stability and ultimate osseointegration, would likely result in greater knee replacement success. Additionally, the removal of cement from the procedure would help minimize surgical durations and get rid of the time needed for curing, thereby the chance of infection. The purpose of this biomechanical study was twofold. The first goal was to assess whether vibration analysis techniques can be used to evaluate and characterize initial mechanical stability of cementless implants more accurately than the traditional method of micromotion determination, which employs linear variable differential transducers (LVDTs). Second, an evaluative study was performed to determine the comparative mechanical stability of five designs of cementless tibial components under mechanical loading designed to simulate in vivo forces. The test groups will include a cemented Triathlon Keeled baseplate control group, three different 2-peg cementless baseplates with smooth, mid, and high roughnesses and a 4-peg cement/ess baseplate with mid-roughness.

  2. Fatigue behavior of highly porous titanium produced by powder metallurgy with temporary space holders.

    Science.gov (United States)

    Özbilen, Sedat; Liebert, Daniela; Beck, Tilmann; Bram, Martin

    2016-03-01

    Porous titanium cylinders were produced with a constant amount of temporary space holder (70 vol.%). Different interstitial contents were achieved by varying the starting powders (HDH vs. gas atomized) and manufacturing method (cold compaction without organic binders vs. warm compaction of MIM feedstocks). Interstitial contents (O, C, and N) as a function of manufacturing were measured by chemical analysis. Samples contained 0.34-0.58 wt.% oxygen, which was found to have the greatest effect on mechanical properties. Quasi-static mechanical tests under compression at low strain rate were used for reference and to define parameters for cyclic compression tests. Not unexpectedly, increased oxygen content increased the yield strength of the porous titanium. Cyclic compression fatigue tests were conducted using sinusoidal loading in a servo-hydraulic testing machine. Increased oxygen content was concomitant with embrittlement of the titanium matrix, resulting in significant reduction of compression cycles before failure. For samples with 0.34 wt.% oxygen, R, σ(min) and σ(max) were varied systematically to estimate the fatigue limit (~4 million cycles). Microstructural changes induced by cyclic loading were then characterized by optical microscopy, SEM and EBSD.

  3. Fatigue behavior of highly porous titanium produced by powder metallurgy with temporary space holders.

    Science.gov (United States)

    Özbilen, Sedat; Liebert, Daniela; Beck, Tilmann; Bram, Martin

    2016-03-01

    Porous titanium cylinders were produced with a constant amount of temporary space holder (70 vol.%). Different interstitial contents were achieved by varying the starting powders (HDH vs. gas atomized) and manufacturing method (cold compaction without organic binders vs. warm compaction of MIM feedstocks). Interstitial contents (O, C, and N) as a function of manufacturing were measured by chemical analysis. Samples contained 0.34-0.58 wt.% oxygen, which was found to have the greatest effect on mechanical properties. Quasi-static mechanical tests under compression at low strain rate were used for reference and to define parameters for cyclic compression tests. Not unexpectedly, increased oxygen content increased the yield strength of the porous titanium. Cyclic compression fatigue tests were conducted using sinusoidal loading in a servo-hydraulic testing machine. Increased oxygen content was concomitant with embrittlement of the titanium matrix, resulting in significant reduction of compression cycles before failure. For samples with 0.34 wt.% oxygen, R, σ(min) and σ(max) were varied systematically to estimate the fatigue limit (~4 million cycles). Microstructural changes induced by cyclic loading were then characterized by optical microscopy, SEM and EBSD. PMID:26706551

  4. Cementless Titanium Mesh Fixation of Osteoporotic Burst Fractures of the Lumbar Spine Leads to Bony Healing: Results of an Experimental Sheep Model

    Directory of Open Access Journals (Sweden)

    Anica Eschler

    2016-01-01

    Full Text Available Introduction. Current treatment strategies for osteoporotic vertebral compression fractures (VCFs focus on cement-associated solutions. Complications associated with cement application are leakage, embolism, adjacent fractures, and compromise in bony healing. This study comprises a validated VCF model in osteoporotic sheep in order to (1 evaluate a new cementless fracture fixation technique using titanium mesh implants (TMIs and (2 demonstrate the healing capabilities in osteoporotic VCFs. Methods. Twelve 5-year-old Merino sheep received ovariectomy, corticosteroid injections, and a calcium/phosphorus/vitamin D-deficient diet for osteoporosis induction. Standardized VCFs (type AO A3.1 were created, reduced, and fixed using intravertebral TMIs. Randomly additional autologous spongiosa grafting (G1 or no augmentation was performed (G2, n=6 each. Two months postoperatively, macroscopic, micro-CT and biomechanical evaluation assessed bony consolidation. Results. Fracture reduction succeeded in all cases without intraoperative complications. Bony consolidation was proven for all cases with increased amounts of callus development for G2 (58.3%. Micro-CT revealed cage integration. Neither group showed improved results with biomechanical testing. Conclusions. Fracture reduction/fixation using TMIs without cement in osteoporotic sheep lumbar VCF resulted in bony fracture healing. Intravertebral application of autologous spongiosa showed no beneficial effects. The technique is now available for clinical use; thus, it offers an opportunity to abandon cement-associated complications.

  5. Cementless total hip arthroplasty with the rectangular titanium Zweymuller stem. A concise follow-up, at a minimum of fifteen years, of a previous report.

    Science.gov (United States)

    Grübl, Alexander; Chiari, Catharina; Giurea, Alexander; Gruber, Martin; Kaider, Alexandra; Marker, Martina; Zehetgruber, Harald; Gottsauner-Wolf, Florian

    2006-10-01

    Between October 1986 and November 1987, 208 total hip arthroplasties were performed with use of the cementless Zweymüller stem and a threaded cup in 200 consecutive patients. Of 102 patients (108 hips) who were available for follow-up at a minimum of 180 months postoperatively, eighty-three (eighty-nine hips) had the primary joint replacement still intact. No stem had been revised because of aseptic loosening, but we found various degrees of osteolysis around sixteen (18%) of the implants. The probability of survival of the stem at fifteen years was 0.98 (95% confidence interval, 0.96 to 1.00). The probability of survival of the cup was 0.85 (95% confidence interval, 0.79 to 0.91). PMID:17015598

  6. Effects of femoral component material properties on cementless fixation in total hip arthroplasty. A comparison study between carbon composite, titanium alloy, and stainless steel.

    Science.gov (United States)

    Otani, T; Whiteside, L A; White, S E; McCarthy, D S

    1993-02-01

    Carbon-fiber-reinforced-carbon composite material is an attractive implant material because its modulus of elasticity can be made similar to that of cortical bone. This study investigated the effect of femoral prosthesis elastic modulus on cementless implant fixation. Distal, as well as proximal, relative micromovements between implant and bone were measured in two testing protocols (axial-load and torsional-load), comparing identically shaped carbon composite (modulus of elasticity = 18.6 GPa), Ti6Al4V (100 GPa), and 630 stainless steel (200 GPa) prostheses. In the axial-load test, proximal mediolateral micromotions were significantly larger in the flexible composite stem than in the two metals. In the torsional-load test, rotational micromotions and "slop" displacements in the flexible stem were significantly larger proximally and significantly smaller distally than in the two metals. While these results suggest that proximal stress transfer may be improved by a flexible stem, they raise the possibility of increased proximal micromotion, and suggest that improved proximal fixation may be necessary to achieve clinical success with flexible composite femoral components.

  7. Good performance of a titanium femoral component in cementless hip arthroplasty in younger patients: 97 arthroplasties followed for 5-11 years

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Jensen, Frank Krieger; Poulsen, Klaus;

    2003-01-01

    We performed 97 uncemented primary total hip arthroplasties in 80 patients having an average age of 50 years. The femoral implant was a titanium stem with a proximal circumferential plasma spray-coating. Three different acetabular components were used: a threaded and partly porous-coated design i...

  8. Cementless Hydroxyapatite Coated Hip Prostheses

    Directory of Open Access Journals (Sweden)

    Antonio Herrera

    2015-01-01

    Full Text Available More than twenty years ago, hydroxyapatite (HA, calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical experience includes the implantation of more than 4,000 cementless hydroxyapatite coated hip prostheses since 1990. The models implanted are coated with HA in the acetabulum and in the metaphyseal area of the stem. The results corresponding to survival and stability of implants were very satisfactory in the long-term. From our experience, HA-coated hip implants are a reliable alternative which can achieve long term survival, provided that certain requirements are met: good design selection, sound choice of bearing surfaces based on patient life expectancy, meticulous surgical technique, and indications based on adequate bone quality.

  9. Antibacterial Efficacy of a New Gentamicin-Coating for Cementless Prostheses Compared to Gentamicin-Loaded Bone Cement

    NARCIS (Netherlands)

    Neut, Danielle; Dijkstra, Rene J. B.; Thompson, Jonathan I.; van der Mei, Henny C.; Busscher, Henk J.

    2011-01-01

    Cementless prostheses are increasingly popular but require alternative prophylactic measures than the use of antibiotic-loaded bone cements. Here, we determine the 24-h growth inhibition of gentamicin-releasing coatings from grit-blasted and porous-coated titanium alloys, and compare their antibacte

  10. Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    van Raaij Jos JAM

    2008-10-01

    Full Text Available Abstract Background Osteoarthritis of the hip is successfully treated by total hip arthroplasty with metal-on-polyethylene articulation. Polyethylene wear debris can however lead to osteolysis, aseptic loosening and failure of the implant. Large head metal-on-metal total hip arthroplasty may overcome polyethylene wear induced prosthetic failure, but can increase systemic cobalt and chromium ion concentrations. The objective of this study is to compare two cementless total hip arthroplasties: a conventional 28 mm metal-on-polyethylene articulation and a large head metal-on-metal articulation. We hypothesize that the latter arthroplasties show less bone density loss and higher serum metal ion concentrations. We expect equal functional scores, greater range of motion, fewer dislocations, fewer periprosthetic radiolucencies and increased prosthetic survival with the metal-on-metal articulation. Methods A randomized controlled trial will be conducted. Patients to be included suffer from non-inflammatory degenerative joint disease of the hip, are aged between 18 and 80 and are admitted for primary cementless unilateral total hip arthroplasty. Patients in the metal-on-metal group will receive a cementless titanium alloy acetabular component with a cobalt-chromium liner and a cobalt-chromium femoral head varying from 38 to 60 mm. Patients in the metal-on-polyethylene group will receive a cementless titanium alloy acetabular component with a polyethylene liner and a 28 mm cobalt-chromium femoral head. We will assess acetabular bone mineral density by dual energy x-ray absorptiometry (DEXA, serum ion concentrations of cobalt, chromium and titanium, self reported functional status (Oxford hip score, physician reported functional status and range of motion (Harris hip score, number of dislocations and prosthetic survival. Measurements will take place preoperatively, perioperatively, and postoperatively (6 weeks, 1 year, 5 years and 10 years. Discussion

  11. Cementless isoelastic RM total hip prosthesis1

    OpenAIRE

    Bombelli, Renato; Mathys, Robert

    1982-01-01

    Some surgeons are beginning to doubt the reliability of bone cement in joint replacements. In 1967 Robert Mathys conceived the idea of an isoelastic prosthesis made of plastic, which would anchor into the bone without cement. He developed the idea by extensive tests in animals and, in 1973, the first human RM cementless hip prosthesis was inserted by E Morscher. In this paper the concept of the cementless isoelastic prosthesis is developed by Robery Mathys, and Professor Bombelli records his ...

  12. Titanium

    Science.gov (United States)

    Bedinger, G.M.

    2013-01-01

    Titanium is the ninth most abundant element in the earth’s crust and can be found in nearly all rocks and sediments. It is a lithophile element with a strong affinity for oxygen and is not found as a pure metal in nature. Titanium was first isolated as a pure metal in 1910, but it was not until 1948 that metal was produced commercially using the Kroll process (named after its developer, William Kroll) to reduce titanium tetrachloride with magnesium to produce titanium metal.

  13. Bone remodeling around cementless tantalum cups

    NARCIS (Netherlands)

    Grillo, J. -C.; Flecher, X.; Bouvenot, J.; Argenson, J. -N.

    2008-01-01

    Purpose of the study.-Most studies have reported a significant decrease in periacetabular bone stock one year after implantation of a cementless cup. The purpose of this work was to study the bone-implant interface of the tantalum cup using plain X-rays and dual-energy X-ray absorptiometry (DEXA). M

  14. MECHANICAL STRENGTH OF HIGHLY POROUS CERAMICS

    NARCIS (Netherlands)

    VANDENBORN, IC; SANTEN, A; HOEKSTRA, HD; DEHOSSON, JTM; Born, I.C. van den

    1991-01-01

    This paper reports on the mechanical strength of highly porous ceramics in terms of the Weibull and Duxbury-Leath distributions. More than 1000 side-crushing strength tests on silica-catalyst carriers of various particle sizes have been performed in series. Within a series, preparation conditions we

  15. Osseointegration: a review of the fundamentals for assuring cementless skeletal fixation

    Directory of Open Access Journals (Sweden)

    Isaacson BM

    2014-04-01

    Full Text Available Brad M Isaacson,1,2 Sujee Jeyapalina3,4 1Henry M Jackson Foundation for the Advancement of Military Medicine, 2The Center for Rehabilitation Sciences Research, Department of Physical Medicine and Rehabilitation, Uniformed Services University of Health Sciences, Bethesda, MD, USA; 3Department of Orthopedics, 4Orthopedic Research Laboratory, University of Utah, Salt Lake City, UT, USA Abstract: Direct skeletal fixation, termed osseointegration, has expanded in the last century and includes use in total joint replacements, the edentulous mandible and maxilla, and percutaneous osseointegrated prosthetics. Although it is well known that titanium and bone have the ability to form a durable bone–implant interface, new applications have emerged in the field of orthopedics, which requires a more thorough assessment of the literature. This review aims to introduce the basic biological principles for attaining osseointegration and discusses the major factors for assuring successful cementless fixation. Keywords: osseointegration, bone, skeletal attachment, total joint replacements, dental implants, percutaneous

  16. A Femur-Implant Model for the Prediction of Bone Remodeling Behavior Induced by Cementless Stem

    Institute of Scientific and Technical Information of China (English)

    He Gong; Lingyan Kong; Rui Zhang; Juan Fang; Meisheng Zhao

    2013-01-01

    Bone remodeling simulation is an effective tool for the prediction of long-term effect of implant on the bone tissue,as well as the selection of an appropriate implant in terms of architecture and material.In this paper,a finite element model of proximal femur was develop.ed to simulate the structures of internal trabecular and cortical bones by incorporating quantitative bone functional adaptation theory with finite element analysis.Cementless stems made of titanium,two types of Functionally Graded Material (FGM) and flexible 'iso-elastic' material as comparison were implanted in the structure of proximal femur respectively to simulate the bone remodeling behaviors of host bone.The distributions of bone density,von Mises stress,and interface shear stress were obtained.All the prosthetic stems had effects on the bone remodeling behaviors of proximal femur,but the degrees of stress shielding were different.The amount of bone loss caused by titanium implant was in agreement with the clinical observation.The FGM stems caused less bone loss than that of the titanium stem,in which FGM I stem (titanium richer at the top to more HAP/Col towards the bottom) could relieve stress shielding effectively,and the interface shear stresses were more evenly distributed in the model with FGM I stem in comparison with those in the models with FGM II (titanium and bioglass) and titanium stems.The numerical simulations in the present study provided theoretical basis for FGM as an appropriate material of femoral implant from a biomechanical point of view.The next steps are to fabricate FGM stem and to conduct animal experiments to investigate the effects of FGM stem on the remodeling behaviors using animal model.

  17. Modified cementless total coxofemoral prosthesis: development, implantation and clinical evaluation

    Directory of Open Access Journals (Sweden)

    S.A. Arias

    2013-12-01

    Full Text Available The aim of this study was to modify canine coxofemoral prostheses and the clinical evaluation of the implantation. Fifteen canine hips and femora of cadavers were used in order to study the surface points of modification in prostheses and develop a perforation guide. Femoral stems and acetabular components were perforated and coated with biphasic calcium phosphate layer. Twelve young adult male mongrel dogs were implanted with coxofemoral prostheses. Six were operated upon and implanted with cemented canine modular hip prostheses, establishing the control group. The remaining six were implanted with a novel design of cementless porous tricalcic phosphate-hydroxyapatite coated hip prostheses. Clinical and orthopedic performance, complications, and thigh muscular hypotrophy were assessed up to the 120th post-operatory day. After 120 days, animals with cementless prostheses had similar clinical and orthopedic performance compared to the cemented group despite the increased pain thigh hypotrophy. Animals that underwent cementless hip prosthesis evidenced more pain, compared to animals with cemented hip prosthesis that required longer recuperation time. No luxations, two fractures and two isquiatic neurapraxies were identified in the course of the study. Using both the cemented and the bioactive coated cementless model were suitable to dogs, showing clinical satisfactory results. Osseointegration and biological fixation were observed in the animals with the modified cementless hip prosthesis.

  18. Short term results of cementless total hip arthroplasty in sicklers

    Directory of Open Access Journals (Sweden)

    Yash Gulati

    2015-01-01

    Conclusion: THA in sicklers involves considerable challenge for the orthopedic surgeon. Management requires a multidisciplinary approach involving the anesthetist, hematologist and the orthopedic surgeon. Contrary to previous reports, THA in sicklers now has a predictable outcome especially with the use of cementless implants.

  19. Design optimization of cementless metal-backed cup prostheses using the concept of functionally graded material

    Energy Technology Data Exchange (ETDEWEB)

    Hedia, H S; El-Midany, T T; Shabara, M A N; Fouda, N [Production Engineering and M/C Design Department, Faculty of Engineering, Mansoura University, Mansoura (Egypt)

    2006-09-15

    Metal backing has been widely used in acetabular cup design. A stiff backing for a polyethylene liner was initially believed to be mechanically favourable. Yet, recent studies of the load transfer around acetabular cups have shown that a stiff backing causes two problems. It generates higher stress peaks around the acetabular rim than those caused by full polyethylene cups and reduces the stresses transferred to the dome of the acetabulum causing stress shielding. The aim of this study is to overcome these two problems by improving the design of cementless metal-backed acetabular cups using the two-dimensional functionally graded material (FGM) concept through finite-element analysis and optimization techniques. It is found that the optimal 2D FGM model must have three bioactive materials of hydroxyapatite, Bioglass and collagen. This optimal material reduces the stress shielding at the dome of the acetabulum by 40% and 37% compared with stainless steel and titanium metal backing shells, respectively. In addition, using the 2D FGM model reduces the maximum interface shear stress in the bone by 31% compared to the titanium metal backing shell.

  20. Bone ingrowth through porous titanium granulate around a femoral stem: histological assessment in a six-month canine hemiarthroplasty model.

    Science.gov (United States)

    Turner, Thomas M; Urban, Robert M; Hall, Deborah J; Andersson, Gunnar B J

    2007-01-01

    The procedure of using of porous titanium granules for cementless fixation of a hip replacement femoral stem was studied in a hemiarthroplasty model in 10 canines for 6 months. A vibrating instrument was used to facilitate both the delivery and distribution of the irregularly shaped porous titanium granules into the femoral canal as well as the subsequent insertion of a titanium alloy stem into the intramedullary bed of granules. Histological examination revealed lamellar bone formation through the mantle of porous titanium granules in continuity with the surrounding cortex resulting in the formation of an integrated mantle of bone and titanium granulate around the prosthesis. PMID:17578819

  1. Highly porous nanoberyllium for X-ray beam speckle suppression

    Energy Technology Data Exchange (ETDEWEB)

    Goikhman, Alexander, E-mail: agoikhman@ymail.com; Lyatun, Ivan; Ershov, Petr [Immanuel Kant Baltic Federal University, Nevskogo str. 14, Kaliningrad 236041 (Russian Federation); Snigireva, Irina [European Synchrotron Radiation Facility, BP 220, 38043 Grenoble (France); Wojda, Pawel [Immanuel Kant Baltic Federal University, Nevskogo str. 14, Kaliningrad 236041 (Russian Federation); Gdańsk University of Technology, 11/12 G. Narutowicza, Gdańsk 80-233 (Poland); Gorlevsky, Vladimir; Semenov, Alexander; Sheverdyaev, Maksim; Koletskiy, Viktor [A. A. Bochvar High-Technology Scientific Research Institute for Inorganic Materials, Rogova str. 5a, Moscow 123098 (Russian Federation); Snigirev, Anatoly [Immanuel Kant Baltic Federal University, Nevskogo str. 14, Kaliningrad 236041 (Russian Federation); European Synchrotron Radiation Facility, BP 220, 38043 Grenoble (France)

    2015-04-09

    A speckle suppression device containing highly porous nanoberyllium is proposed for manipulating the spatial coherence length and removing undesirable speckle structure during imaging experiments. This paper reports a special device called a ‘speckle suppressor’, which contains a highly porous nanoberyllium plate squeezed between two beryllium windows. The insertion of the speckle suppressor in an X-ray beam allows manipulation of the spatial coherence length, thus changing the effective source size and removing the undesirable speckle structure in X-ray imaging experiments almost without beam attenuation. The absorption of the nanoberyllium plate is below 1% for 1 mm thickness at 12 keV. The speckle suppressor was tested on the ID06 ESRF beamline with X-rays in the energy range from 9 to 15 keV. It was applied for the transformation of the phase–amplitude contrast to the pure amplitude contrast in full-field microscopy.

  2. Highly porous nanoberyllium for X-ray beam speckle suppression

    International Nuclear Information System (INIS)

    A speckle suppression device containing highly porous nanoberyllium is proposed for manipulating the spatial coherence length and removing undesirable speckle structure during imaging experiments. This paper reports a special device called a ‘speckle suppressor’, which contains a highly porous nanoberyllium plate squeezed between two beryllium windows. The insertion of the speckle suppressor in an X-ray beam allows manipulation of the spatial coherence length, thus changing the effective source size and removing the undesirable speckle structure in X-ray imaging experiments almost without beam attenuation. The absorption of the nanoberyllium plate is below 1% for 1 mm thickness at 12 keV. The speckle suppressor was tested on the ID06 ESRF beamline with X-rays in the energy range from 9 to 15 keV. It was applied for the transformation of the phase–amplitude contrast to the pure amplitude contrast in full-field microscopy

  3. Interface Micromotion of Cementless Hip Stems in Simulated Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Mohammed R.A. Kadir

    2009-01-01

    Full Text Available Problem statement: The design of hip prostheses has evolved over time due to various complications found after hip replacement surgery. The currently commercially available cementless femoral stems can be categorized into one of three major types, straight cylindrical, tapered rectangular and anatomical. Each type proposes a unique concept to achieve primary stability-a major requirement for bone healing process. Virtual analyses have been made on individual implants, but comparison between the three major types is required to determine the strength and weaknesses of the design concepts. Approach: Three types of implants were modeled in three dimensions-the straight cylindrical, rectangular taper and anatomical. The size of the three implants was carefully designed to fit and fill the canal of a femur reconstructed from a computed tomography image dataset. Hip arthroplasty was simulated virtually by inserting the hip stem into the femoral canal. Finite element method was used in conjunction with a specialized sub-routine to measure micromotion at the bone-implant interface under loads simulating physiological walking and stair-climbing. Another sub-routine was used to assign bone properties based on the grayscale values of the CT image. Results: All the three types of cementless hip stems were found to be stable under both walking and stair climbing activities. Large micromotion values concentrated around the proximal and distal part of the stems. Conclusion/Recommendations: The three major types of hip stems were compared in this study and all of them were found to be stable after simulated physiological activities.

  4. Superior fixation of pegged trabecular metal over screw-fixed pegged porous titanium fiber mesh

    OpenAIRE

    Stilling, Maiken; Madsen, Frank; Odgaard, Anders; Rømer, Lone; Andersen, Niels Trolle; Rahbek, Ole; Søballe, Kjeld

    2011-01-01

    Background and purpose Lasting stability of cementless implants depends on osseointegration into the implant surface, and long-term implant fixation can be predicted using radiostereometric analysis (RSA) with short-term follow-up. We hypothesized that there would be improved fixation of high-porosity trabecular metal (TM) tibial components compared to low-porosity titanium pegged porous fiber-metal (Ti) polyethylene metal backings. Methods In a prospective, parallel-group, randomized unblind...

  5. Do Rerevision Rates Differ After First-time Revision of Primary THA With a Cemented and Cementless Femoral Component?

    DEFF Research Database (Denmark)

    Gromov, Kirill; Pedersen, Alma B; Overgaard, Søren;

    2015-01-01

    Worldwide use of cementless fixation for total hip arthroplasty (THA) is on the rise despite some evidence from the world's registries suggesting inferior survivorship compared with cemented techniques. The patterns of bone loss associated with failed cementless and cemented THAs may prejudice...

  6. Towards a Dynamical Collision Model of Highly Porous Dust Aggregates

    CERN Document Server

    Güttler, Carsten; Geretshauser, Ralf J; Speith, Roland; Blum, Jürgen

    2009-01-01

    In the recent years we have performed various experiments on the collision dynamics of highly porous dust aggregates and although we now have a comprehensive picture of the micromechanics of those aggregates, the macroscopic understanding is still lacking. We are therefore developing a mechanical model to describe dust aggregate collisions with macroscopic parameters like tensile strength, compressive strength and shear strength. For one well defined dust sample material, the tensile and compressive strength were measured in a static experiment and implemented in a Smoothed Particle Hydrodynamics (SPH) code. A laboratory experiment was designed to compare the laboratory results with the results of the SPH simulation. In this experiment, a mm-sized glass bead is dropped into a cm-sized dust aggregate with the previously measured strength parameters. We determine the deceleration of the glass bead by high-speed imaging and the compression of the dust aggregate by x-ray micro-tomography. The measured penetration...

  7. Instationary compaction wave propagation in highly porous cohesive granular media

    Science.gov (United States)

    Gunkelmann, Nina; Ringl, Christian; Urbassek, Herbert M.

    2016-07-01

    We study the collision of a highly porous granular aggregate of adhesive \\upmu m-sized silica grains with a hard wall using a granular discrete element method. A compaction wave runs through the granular sample building up an inhomogeneous density profile. The compaction is independent of the length of the aggregate, within the regime of lengths studied here. Also short pulses, as they might be exerted by a piston pushing the granular material, excite a compaction wave that runs through the entire material. The speed of the compaction wave is larger than the impact velocity but considerably smaller than the sound speed. The wave speed is related to the compaction rate at the colliding surface and the average slope of the linear density profile.

  8. THE HIGH VOLUME REUSE OF HYBRID BIOMASS ASH AS A PRIMARY BINDER IN CEMENTLESS MORTAR BLOCK

    Directory of Open Access Journals (Sweden)

    Cheah Chee Ban

    2014-01-01

    Full Text Available High Calcium Wood Ash (HCWA and Pulverised Fuel Ash (PFA are by-products from the wood biomass and coal energy production which are produced in large quantity with combined annual production of 500 million tonnes. This poses a serious problem for disposal of the waste material especially at places where land is scarce. The prescribed study was aimed to examine the mineralogical phases and their respective amount present in the industrial wastes which governs the hydration mechanism towards self-sustained solidification of the ashes when used in combination. Besides, the influence of various forming pressure and hydrothermal treatment temperature on mechanical strength performance of HCWA-PFA cementless mortar blocks was also examined. In the study, the mechanical strength of the HCWA-PFA cementless mortar block produced using various forming pressure and hydrothermal treatment temperature was assessed in terms of compressive strength and dynamic modulus. The results of the study are indicative that HCWA is rich in calcium oxide and potassium oxide content. This enables the hybridization of HCWA with the amorphous silica and alumina rich PFA to form a solid geopolymer binder matrix for fabrication of cementless mortar block. Throughout the study, dimensionally and mechanically stable HCWA-PFA geopolymer mortar blocks were successfully produced by press forming and hydrothermal treatment method. Based on statistical analysis, the hydrothermal treatment temperature has a statistically insignificant effect on the mechanical strength of the HCWA-PFA cementless mortar blocks. The dominant factor which governs the mechanical strength of the HCWA-PFA cementless mortar blocks was found to be the hydraulic forming pressure. Moreover, it was found that hybridized HCWA-PFA can be recycled as the sole binder for fabrication of cementless concrete block which is a useful construction material.

  9. Study of bone remodeling of two models of femoral cementless stems by means of DEXA and finite elements

    Directory of Open Access Journals (Sweden)

    López-Prats Fernando

    2010-05-01

    Full Text Available Abstract Background A hip replacement with a cemented or cementless femoral stem produces an effect on the bone called adaptive remodelling, attributable to mechanical and biological factors. All of the cementless prostheses designs try to achieve an optimal load transfer in order to avoid stress-shielding, which produces an osteopenia. Long-term densitometric studies taken after implanting ABG-I and ABG-II stems confirm that the changes made to the design and alloy of the ABG-II stem help produce less proximal atrophy of the femur. The simulation with FE allowed us to study the biomechanical behaviour of two stems. The aim of this study was, if possible, to correlate the biological and mechanical findings. Methods Both models with prostheses ABG-I and II have been simulated in five different moments of time which coincide with the DEXA measurements: postoperative, 6 months, 1, 3 and 5 years, in addition to the healthy femur as the initial reference. For the complete comparative analysis of both stems, all of the possible combinations of bone mass (group I and group II of pacients in two controlled studies for ABG-I and II stems, respectively, prosthetic geometry (ABG-I and ABG-II and stem material (Wrought Titanium or TMZF were simulated. Results and Discussion In both groups of bone mass an increase of stress in the area of the cancellous bone is produced, which coincides with the end of the HA coating, as a consequence of the bottleneck effect which is produced in the transmission of loads, and corresponds to Gruen zones 2 and 6, where no osteopenia can be seen in contrast to zones 1 and 7. Conclusions In this study it is shown that the ABG-II stem is more effective than the ABG-I given that it generates higher tensional values on the bone, due to which proximal bone atrophy diminishes. This biomechanical behaviour with an improved transmission of loads confirmed by means of FE simulation corresponds to the biological findings obtained with

  10. Preparation and properties of highly porous, biomorphic YSZ ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Rambo, C.R.; Cao, J.; Sieber, H

    2004-10-15

    Highly porous, biomorphic YSZ (yttria-stabilized zirconia) ceramics were manufactured by infiltration of zirconium-oxychloride (ZrOCl{sub 2}{center_dot}8H{sub 2}O) sol into biological template structures derived from rattan and pine wood. 3-5 mol% yttrium nitrate (Y(NO{sub 3}){sub 3}{center_dot}5H{sub 2}O) was added to the sol to stabilize the tetragonal ZrO{sub 2} phase. After vacuum-assisted infiltration, the specimens were pyrolysed at 800 deg. C in N{sub 2} atmosphere. Repeated infiltrations and subsequent annealing in air at temperatures up to 1550 deg. C yields the burn out of the biocarbon template and resulted in the formation of biomorphous YSZ ceramics, which maintained the microstructural features of the biological preform. Depending on the type of the biological template as well as the processing parameters, biomorphic ZrO{sub 2} ceramics with an unidirected pore morphology and a large variety of microstructures can be obtained.

  11. Towards a Dynamical Collision Model of Highly Porous Dust Aggregates

    Science.gov (United States)

    Güttler, Carsten; Krause, Maya; Geretshauser, Ralf; Speith, Roland; Blum, Jürgen

    2009-06-01

    In the recent years we have performed various experiments on the collision dynamics of highly porous dust aggregates and although we now have a comprehensive picture of the micromechanics of those aggregates, the macroscopic understanding is still lacking. We are therefore developing a mechanical model to describe dust aggregate collisions with macroscopic parameters like tensile strength, compressive strength and shear strength. For one well defined dust sample material, the tensile and compressive strength were measured in a static experiment and implemented in a Smoothed Particle Hydrodynamics (SPH) code. A laboratory experiment was designed to compare the laboratory results with the results of the SPH simulation. In this experiment, a mm-sized glass bead is dropped into a cm-sized dust aggregate with the previously measured strength parameters. We determine the deceleration of the glass bead by high-speed imaging and the compression of the dust aggregate by x-ray micro-tomography. The measured penetration depth, stopping time and compaction under the glass bead are utilized to calibrate and test the SPH code. We find that the statically measured compressive strength curve is only applicable if we adjust it to the dynamic situation with a ``softness'' parameter. After determining this parameter, the SPH code is capable of reproducing experimental results, which have not been used for the calibration before.

  12. Effect of rotator cuff dysfunction on the initial mechanical stability of cementless glenoid components

    NARCIS (Netherlands)

    D.R. Suárez (Daniel); E.R. Valstar (Edward); J.C. Linden (Jacqueline); F. van Keulen (Fred); P.M. Rozing (Piet)

    2009-01-01

    textabstractThe functional outcome of shoulder replacement is related to the condition of the rotator cuff. Rotator cuff disease is a common problem in candidates for total shoulder arthroplasty; this study relates the functional status of the rotator cuff to the initial stability of a cementless gl

  13. A biodegradable gentamicin-hydroxyapatite-coating for infection prophylaxis in cementless hip prostheses

    NARCIS (Netherlands)

    Neut, D.; Dijkstra, R. J. B.; Thompson, J. I.; Kavanagh, C.; van der Mei, H. C.; Busscher, H. J.

    2015-01-01

    A degradable, poly (lactic-co-glycolic acid) (PLGA), gentamicin-loaded prophylactic coating for hydroxyapatite (HA)-coated cementless hip prostheses is developed with similar antibacterial efficacy as offered by gentamicin-loaded cements for fixing traditional, cemented prostheses in bone. We descri

  14. Effect of proximal femoral osteoporosis on cementless hip arthroplasty: A short-term clinical analysis

    Institute of Scientific and Technical Information of China (English)

    LOU Xian-feng; LI Yu-hong; LIN Xiang-jin

    2007-01-01

    Objective: The aim of this retrospective investigation was to explore the influence of femoral osteoporosis on short-term curative effects of cementless hip arthroplasty and to evaluate the femoral metaphyseal bone mineral density (BMD) for femoral osteoporosis in order to guide prosthesis choice and rehabilitation. Methods: We performed 127 total arthroplasty operations between June 1999 to February 2003 and investigated 49 cementless hip replacements with the Metalcancellous cementless Lubeck Ⅱ system being used in all hips. There were twenty men and twenty-nine women whose mean age at the time of the operation was 60 years (range, 52~81 years). The patients were divided into osteoporosis or normal groups according to the femoral metaphyseal BMD measured preoperatively. The average duration of follow-up was 30 months (range, 8~52 months). We evaluated all of the patients from a clinical standpoint with use of a standard-terminology questionnaire with respect to the short-term curative effects and patients' satisfaction. Hip pain status and functional ability were important indicators of treatment efficacy. Results: Harris hip score and patients' satisfaction in femoral osteoporosis patients who underwent noncemented hip arthroplasty were lower (P=0.004, P=0.03) while the incidence of thigh pain was higher (P=0.03) than the patients with non-osteoporosis. Conclusion: The higher incidence of pain, as well as the decrease in function experienced by the patients in osteoporosis group, supports the case that cementless arthroplasty is not a better choice for those patients and that we had better select prosthesis based on the femoral metaphyseal BMD.

  15. Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

    Directory of Open Access Journals (Sweden)

    Gholam Hossein Shahcheraghi

    2015-09-01

    Full Text Available Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations. Methods: 52 primary cementless total hip arthroplasty in 42 patients with the mean age of 48.8 years were retrospectively studied. Two groups of prosthesis had been implanted: Harris-Galante II (HGII in 15 and Versys-Trilogy (V-T in 37 hips, both from Zimmer company. The patients were assessed clinically, radiographically and with Harris hip score, SF36, WOMAC, and MACTAR questionnaires, with 65 months (26-136 mean follow-up. Results: All the V-T prostheses had survived well. Eight of HG II were revised by the last follow-up in 19-102 months. All had undergone acetabular revision and 2 combined with femoral revision. Broken tines of HGII cups were seen in 4 radiographs. The 65 months overall survival was 96.2% for femoral and 84.6% for acetabular components. 90% had good or excellent Harris hip scores. The functional scores were poorer in the HG II group. Pain relief and improved walking were the two main patients’ expectations fulfilled in 97.6% and 92.8%, respectively. Conclusions: The outcome of cementless total hip arthroplasty (THA is satisfactory and comparable with the literature based on the results of function and survival of this small comparative group. The use of HGII acetabular component should be abandoned.

  16. Surface characterization and effectiveness evaluation of anti-graffiti coatings on highly porous stone materials

    Science.gov (United States)

    Lettieri, Mariateresa; Masieri, Maurizio

    2014-01-01

    In this study, two commercial sacrificial anti-graffiti systems, provided as water emulsion, were applied on a highly porous stone. The behavior of the anti-graffiti treatments was investigated by means of differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy in attenuated total reflectance mode (ATR-FTIR), colorimetric tests, and water static contact angle measurements.

  17. Electrospinning of silver nanoparticles loaded highly porous cellulose acetate nanofibrous membrane for treatment of dye wastewater

    Science.gov (United States)

    Wang, Ke; Ma, Qian; Wang, Shu-Dong; Liu, Hua; Zhang, Sheng-Zhong; Bao, Wei; Zhang, Ke-Qin; Ling, Liang-Zhong

    2016-01-01

    In this paper, silver nanoparticles (NPs) were reduced form silver nitrate. Morphology and distribution of the synthesized silver NPs were characterized. In order to obtain cellulose acetate (CA), nanofibrous membrane with high effective adsorption performance to carry silver NPs for treatment of dye wastewater, different solvent systems were used to fabricate CA nanofibrous membranes with different morphologies and porous structures via electrospinning. Morphologies and structures of the obtained CA nanofibrous membranes were compared by scanning electron microscopy (SEM), which showed that CA nanofibrous membrane obtained from acetone/dichloromethane (1/2, v/v) was with the highly porous structure. SEM, energy-dispersive spectrometry and Fourier transform infrared spectrometry showed that the silver NPs were effectively incorporated in the CA nanofibrous membrane and the addition of silver NPs did not damage the porous structure of the CA nanofibrous membrane. Adsorption of dye solution (rhodamine B aqueous solution) revealed that the highly porous CA nanofibrous membrane exhibited effective adsorption performance and the addition of silver NPs did not affect the adsorption of the dye. Antibacterial property of the CA nanofibrous membrane showed that the silver-loaded highly porous CA nanofibrous membrane had remarkable antibacterial property when compared to the CA nanofibrous membrane without silver NPs. The silver-loaded highly porous CA nanofibrous membrane could be considered as an ideal candidate for treatment of the dye wastewater.

  18. Titanium 2013

    Science.gov (United States)

    2014-01-01

    Titanium is the ninth most abundant element in the earth's crust and can be found in nearly all rocks and sediments. It is a lithophile element with a strong affinity for oxygen and is not found as a pure metal in nature. Titanium was first isolated as a pure metal in 1910, but it was not until 1948 that the metal was produced commercially using the Kroll process (named after its developer, William Kroll) to reduce titanium tetrachloride with magnesium to produce titanium metal.

  19. Radiographic and clinical analysis of cementless acetabular fixation in total hip arthroplasty

    Institute of Scientific and Technical Information of China (English)

    ZHANG Hui; PEI Fu-xing; YANG Jing; SHEN Bin; SHI Rui

    2005-01-01

    Objective: To investigate the factors affecting the fixation, loosening and therapeutic effect of cementless acetabular prosthesis through following up the patients with total hip arthroplasty clinically and radiographically.Methods: From February 1998 to May 1999, 139 patients (148 hips) underwent total hip arthroplasty with cementless acetabular prosthesis in our department. In this study, the clinical therapeutic effect and the anteroposterior radiographs of the pelvis and anteroposterior and lateral radiographs of the hips of 109 patients (116 hips) made before operation, at 1 week, 3, 6, and 12 months after operation and annually thereafter were analyzed retrospectively. The clinical therapeutic effects were evaluated with Harris hip score. Radiographs were used to observe the position of prostheses and the bone changes around the implant, and to measure the wearing speed and direction of the acetabular cup. All evaluations were made by an independent examiner who did not participate in the operation. The patients were followed up for 5-6 years.Results: The mean Harris score was 44 points (range, 10-70 points) before operation, but it increased to 92.4 points (range, 80-100 points) at the latest review after operation, which was significantly higher than that before operation (P<0.05). No acetabular component was revised because of infection or aseptic loosening. And no acetabular component migrated. There was no revision of fixed acetabular component because of pelvic osteolysis secondary to polyethylene wear. The mean linear wear rate was 0.15 mm per year. All the acetabular prostheses were classified as stable on the radiographs.Conclusions: In terms of fixation, total hip arthroplasty with cementless acetabular components was successful. Although there is no aseptic loosening and a low incidence of osteolysis at the latest follow-up evaluation, polyethylene wear cannot be avoided and can lead to expansile osteolysis near the cups. This kind of osteolysis

  20. Stable Fixation of a Cementless, Proximally Coated, Double Wedged, Double Tapered Femoral Stem in Total Hip Arthroplasty

    DEFF Research Database (Denmark)

    Nebergall, Audrey K; Rolfson, Ola; Rubash, Harry E;

    2016-01-01

    BACKGROUND: The objective of this 5-year prospective study of 51 hips was to assess migration of a cementless tapered femoral stem using radiostereometric analysis (RSA), plain radiographs (radiolucencies), and patient-reported outcome measures (PROMs). METHODS: Forty-seven patients (51 hips...

  1. Effects of Materials of Cementless Femoral Stem on the Functional Adaptation of Bone

    Institute of Scientific and Technical Information of China (English)

    He Gong; Wei Wu; Juan Fang; Xin Dong; Meisheng Zhao; Tongtong Guo

    2012-01-01

    The objective of this paper is to identify the effects of materials of cementless femoral stem on the functional adaptive behaviors of bone.The remodeling behaviors of a two-dimensional simplified model of cementless hip prosthesis with stiff stem,flexible 'iso-elastic' stem,one-dimensional Functionally Graded Material (FGM) stem and two-dimensional FGM stem for the period of four years after prosthesis replacement were quantified by incorporating the bone remodeling algorithm with finite element analysis.The distributions of bone density,von Mises stress,and interface shear stress were obtained.The results show that two-dimensional FGM stem may produce more mechanical stimuli and more uniform interface shear stress compared with the stems made of other materials,thus the host bone is well preserved.Accordingly,the two-dimensional FGM stem is an appropriate femoral implant from a biomechanical point of view.The numerical simulation in this paper can provide a quantitative computational paradigm for the changes of bone morphology caused by implants,which can help to improve the design of implant to reduce stress shielding and the risk of bone-prosthesis interface failure.

  2. The use of cementless acetabular component in revision surgery without pelvic discontinuity.

    Science.gov (United States)

    Cherubino, Paolo; D'Angelo, Fabio; Surace, Michele Francesco; Murena, Luigi; Vulcano, Ettore

    2010-10-01

    Reconstruction of the failed acetabular component in total hip arthroplasty (THA) can be challenging. Although there are multiple reconstructive options available, a cementless acetabular component inserted with screws has been shown to have good intermediate-term results and is the reconstructive method of choice for the majority of acetabular revisions This reconstruction is feasible provided at least 50% of the implant contacts host bone. When such contact is not possible, and there is adequate medial and peripheral bone, techniques using alternative uncemented implants can be used for acetabular reconstruction. An uncemented cup can be placed at a "high hip center." Alternatively, the acetabular cavity can be progressively reamed to accommodate extra-large cups. Oblong cups, which take advantage of the oval-shaped cavity resulting from many failed acetabular components, can also be used. The success of these cementless techniques depends on the degree and location of bone loss. The correct indication to revision and the choice of the correct implant is the keystone for the success of this type of surgery and follows an accurate preoperative planning in order to understand the specific pathologic scenario. The aim of this paper is to review some technical options for the revision of the acetabular component also taking into account our personal experiences and series. PMID:21082580

  3. Utilizing of the metallurgical slag for production of cementless concrete mixtures

    Directory of Open Access Journals (Sweden)

    D. Baricová

    2012-10-01

    Full Text Available In process of pig iron, steel and cast iron production besides main product, also secondary products are formed, that have character of secondary raw materials and industrial wastes. The most abundant secondary product originating in the metallurgical process is furnace slag. Total amount of accured slag, also its chemical, mineralogical, physical – chemical properties and similarity with natural stones predestinate its utilisation in different fields of industry. The contribution deals with production of cementless concrete mixtures, where the main parts were formed by blast furnace granulated slag grinded and different gravel slag from blast furnace, oxygen converter and electric arc furnace. As activators of solidification different kinds of water glass were tested.

  4. Formation of highly porous aerosol particles by atmospheric freeze-drying in ice clouds.

    Science.gov (United States)

    Adler, Gabriela; Koop, Thomas; Haspel, Carynelisa; Taraniuk, Ilya; Moise, Tamar; Koren, Ilan; Heiblum, Reuven H; Rudich, Yinon

    2013-12-17

    The cycling of atmospheric aerosols through clouds can change their chemical and physical properties and thus modify how aerosols affect cloud microphysics and, subsequently, precipitation and climate. Current knowledge about aerosol processing by clouds is rather limited to chemical reactions within water droplets in warm low-altitude clouds. However, in cold high-altitude cirrus clouds and anvils of high convective clouds in the tropics and midlatitudes, humidified aerosols freeze to form ice, which upon exposure to subsaturation conditions with respect to ice can sublimate, leaving behind residual modified aerosols. This freeze-drying process can occur in various types of clouds. Here we simulate an atmospheric freeze-drying cycle of aerosols in laboratory experiments using proxies for atmospheric aerosols. We find that aerosols that contain organic material that undergo such a process can form highly porous aerosol particles with a larger diameter and a lower density than the initial homogeneous aerosol. We attribute this morphology change to phase separation upon freezing followed by a glass transition of the organic material that can preserve a porous structure after ice sublimation. A porous structure may explain the previously observed enhancement in ice nucleation efficiency of glassy organic particles. We find that highly porous aerosol particles scatter solar light less efficiently than nonporous aerosol particles. Using a combination of satellite and radiosonde data, we show that highly porous aerosol formation can readily occur in highly convective clouds, which are widespread in the tropics and midlatitudes. These observations may have implications for subsequent cloud formation cycles and aerosol albedo near cloud edges. PMID:24297908

  5. Preparation and application of highly porous aerogel-based bioactive materials in dentistry

    Science.gov (United States)

    Kuttor, Andrea; Szalóki, Melinda; Rente, Tünde; Kerényi, Farkas; Bakó, József; Fábián, István; Lázár, István; Jenei, Attila; Hegedüs, Csaba

    2014-03-01

    In this study, the possibility of preparation and application of highly porous silica aerogel-based bioactive materials are presented. The aerogel was combined with hydroxyapatite and β-tricalcium phosphate as bioactive and osteoinductive agents. The porosity of aerogels was in the mesoporous region with a maximum pore diameter of 7.4 and 12.7 nm for the composite materials. The newly developed bioactive materials were characterized by scanning electron microscopy. The in vitro biological effect of these modified surfaces was also tested on SAOS-2 osteogenic sarcoma cells by confocal laser scanning microscopy.

  6. Numerical modelling of the strength of highly porous aerated autoclaved concrete

    Energy Technology Data Exchange (ETDEWEB)

    Schenider, T.; Greil, P. [Univ. of Erlangen-Nuernberg, Erlangen (Germany). Dept. of Materials Science; Schober, G. [Hebel AG, Fuerstenfeldbruck (Germany). Materialtechnische Entwicklung

    1998-12-31

    Highly porous building materials like aerated autoclaved concrete are characterized by low thermal conductivity and high mechanical strength, which both strongly depend on porosity. The influence of porosity distribution on the compressive strength of aerated autoclaved concrete was investigated by using finite element analysis and multiaxial Weibull theory. Calculations of failure probability of microstructures with ordered as well as random pore configurations show a dependence of compressive strength on the Weibull modulus of the matrix material and the size and arrangement of pores. The results of the calculations are compared to experimental data of aerated autoclaved concrete.

  7. Preparation and hydrogen storage capacity of highly porous activated carbon materials derived from polythiophene

    OpenAIRE

    Sevilla Solís, Marta; Fuertes Arias, Antonio Benito; Mokaya, R.

    2011-01-01

    [EN] Highly porous carbons have been successfully synthesized by chemical activation of polythiophene with KOH. The activation process was performed under relatively mild activation conditions, i. e., a KOH/polymer weight ratio of 2 and reaction temperatures in the 600–850 °C range. The porous carbons thus obtained possess very large surface areas, up to 3000 m2/g, and pore volumes of up to 1.75 cm3/g. The pore size distribution of these carbons can be tuned via modification of the activation...

  8. Titanium Alloys

    Directory of Open Access Journals (Sweden)

    Mark T. Whittaker

    2015-08-01

    Full Text Available Although originally discovered in the 18th century [1], the titanium industry did not experience any significant advancement until the middle of the 20th century through the development of the gas turbine engine [2]. Since then, the aerospace sector has dominated worldwide titanium use with applications in both engines and airframe structures [3]. The highly desirable combination of properties, which include excellent corrosion resistance, favourable strength to weight ratios, and an impressive resistance to fatigue, has led to an extensive range of applications [4], with only high extraction and processing costs still restricting further implementation. [...

  9. Total hip arthroplasty in patients with avascular necrosis of the hip. Follow-up observations on cementless and cemented operations.

    Science.gov (United States)

    Katz, R L; Bourne, R B; Rorabeck, C H; McGee, H

    1992-08-01

    Thirty-one patients with avascular necrosis of the hip were treated by 34 total hip arthroplasties (THAs). All patients were observed prospectively with a minimum two-year follow-up evaluation (average, 46 months; range, 24-84 months). Twenty had cemented arthroplasties using contemporary cementing techniques. This included insertion of a medullary plug, cleansing of the canal with a medullary brush, pulsatile lavage irrigation, and insertion of the cement with a cement gun. In 14 hips, a cementless prosthesis was used. Patients were rated using a modified Harris hip score. Sequential postoperative roentgenograms were analyzed in each patient. The overall Harris hip score ratings were 88 in the cemented and 84 in the noncemented groups. Mechanical failure with loosening of the femoral component occurred in one patient who developed deep sepsis. Significant thigh pain occurred in four patients in the noncemented group. Previous studies in the literature have generally reported unfavorable results in patients with avascular necrosis of the hip treated with THA. Using cementless and cemented fixation with contemporary cementing techniques, improved results can be expected. A high incidence of thigh pain (29%) in the cementless group remains a problem. PMID:1499201

  10. Migration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Zilkens C

    2011-03-01

    Full Text Available Abstract The aim of this study was to evaluate the initial acetabular implant stability and late acetabular implant migration in press fit cups combined with screw fixation of the acetabular component in order to answer the question whether screws are necessary for the fixation of the acetabular component in cementless primary total hip arthroplasty. One hundred and seven hips were available for follow-up after primary THA using a cementless, porous-coated acetabular component. A total of 631 standardized radiographs were analyzed digitally by the "single-film-x-ray-analysis" method (EBRA. One hundred 'and one (94.4% acetabular components did not show significant migration of more than 1 mm. Six (5.6% implants showed migration of more than 1 mm. Statistical analysis did not reveal preoperative patterns that would identify predictors for future migration. Our findings suggest that the use of screw fixation for cementless porous- coated acetabular components for primary THA does not prevent cup migration.

  11. Migration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty.

    Science.gov (United States)

    Zilkens, C; Djalali, S; Bittersohl, B; Kälicke, T; Kraft, C N; Krauspe, R; Jäger, Marcus

    2011-03-28

    The aim of this study was to evaluate the initial acetabular implant stability and late acetabular implant migration in press fit cups combined with screw fixation of the acetabular component in order to answer the question whether screws are necessary for the fixation of the acetabular component in cementless primary total hip arthroplasty. One hundred and seven hips were available for follow-up after primary THA using a cementless, porous-coated acetabular component. A total of 631 standardized radiographs were analyzed digitally by the "single-film-x-ray-analysis" method (EBRA). One hundred and one (94.4 %) acetabular components did not show significant migration of more than 1 mm. Six (5.6%) implants showed migration of more than 1 mm. Statistical analysis did not reveal preoperative patterns that would identify predictors for future migration. Our findings suggest that the use of screw fixation for cementless porous-coated acetabular components for primary THA does not prevent cup migration. PMID:21486725

  12. Highly porous, low elastic modulus 316L stainless steel scaffold prepared by selective laser melting.

    Science.gov (United States)

    Čapek, Jaroslav; Machová, Markéta; Fousová, Michaela; Kubásek, Jiří; Vojtěch, Dalibor; Fojt, Jaroslav; Jablonská, Eva; Lipov, Jan; Ruml, Tomáš

    2016-12-01

    Recently, porous metallic materials have been extensively studied as candidates for use in the fabrication of scaffolds and augmentations to repair trabecular bone defects, e.g. in surroundings of joint replacements. Fabricating these complex structures by using common approaches (e.g., casting and machining) is very challenging. Therefore, rapid prototyping techniques, such as selective laser melting (SLM), have been investigated for these applications. In this study, we characterized a highly porous (87 vol.%) 316L stainless steel scaffold prepared by SLM. 316L steel was chosen because it presents a biomaterial still widely used for fabrication of joint replacements and, from the practical point of view, use of the same material for fabrication of an augmentation and a joint replacement is beneficial for corrosion prevention. The results are compared to the reported properties of two representative nonporous 316L stainless steels prepared either by SLM or casting and subsequent hot forging. The microstructural and mechanical properties and the surface chemical composition and interaction with the cells were investigated. The studied material exhibited mechanical properties that were similar to those of trabecular bone (compressive modulus of elasticity ~0.15GPa, compressive yield strength ~3MPa) and cytocompatibility after one day that was similar to that of wrought 316L stainless steel, which is a commonly used biomaterial. Based on the obtained results, SLM is a suitable method for the fabrication of porous 316L stainless steel scaffolds with highly porous structures. PMID:27612756

  13. Highly porous, low elastic modulus 316L stainless steel scaffold prepared by selective laser melting.

    Science.gov (United States)

    Čapek, Jaroslav; Machová, Markéta; Fousová, Michaela; Kubásek, Jiří; Vojtěch, Dalibor; Fojt, Jaroslav; Jablonská, Eva; Lipov, Jan; Ruml, Tomáš

    2016-12-01

    Recently, porous metallic materials have been extensively studied as candidates for use in the fabrication of scaffolds and augmentations to repair trabecular bone defects, e.g. in surroundings of joint replacements. Fabricating these complex structures by using common approaches (e.g., casting and machining) is very challenging. Therefore, rapid prototyping techniques, such as selective laser melting (SLM), have been investigated for these applications. In this study, we characterized a highly porous (87 vol.%) 316L stainless steel scaffold prepared by SLM. 316L steel was chosen because it presents a biomaterial still widely used for fabrication of joint replacements and, from the practical point of view, use of the same material for fabrication of an augmentation and a joint replacement is beneficial for corrosion prevention. The results are compared to the reported properties of two representative nonporous 316L stainless steels prepared either by SLM or casting and subsequent hot forging. The microstructural and mechanical properties and the surface chemical composition and interaction with the cells were investigated. The studied material exhibited mechanical properties that were similar to those of trabecular bone (compressive modulus of elasticity ~0.15GPa, compressive yield strength ~3MPa) and cytocompatibility after one day that was similar to that of wrought 316L stainless steel, which is a commonly used biomaterial. Based on the obtained results, SLM is a suitable method for the fabrication of porous 316L stainless steel scaffolds with highly porous structures.

  14. Highly porous activated carbons from resource-recovered Leucaena leucocephala wood as capacitive deionization electrodes.

    Science.gov (United States)

    Hou, Chia-Hung; Liu, Nei-Ling; Hsi, Hsing-Cheng

    2015-12-01

    Highly porous activated carbons were resource-recovered from Leucaena leucocephala (Lam.) de Wit. wood through combined chemical and physical activation (i.e., KOH etching followed by CO2 activation). This invasive species, which has severely damaged the ecological economics of Taiwan, was used as the precursor for producing high-quality carbonaceous electrodes for capacitive deionization (CDI). Carbonization and activation conditions strongly influenced the structure of chars and activated carbons. The total surface area and pore volume of activated carbons increased with increasing KOH/char ratio and activation time. Overgasification induced a substantial amount of mesopores in the activated carbons. In addition, the electrochemical properties and CDI electrosorptive performance of the activated carbons were evaluated; cyclic voltammetry and galvanostatic charge/discharge measurements revealed a typical capacitive behavior and electrical double layer formation, confirming ion electrosorption in the porous structure. The activated-carbon electrode, which possessed high surface area and both mesopores and micropores, exhibited improved capacitor characteristics and high electrosorptive performance. Highly porous activated carbons derived from waste L. leucocephala were demonstrated to be suitable CDI electrode materials. PMID:26135977

  15. Biomechanical evaluation of adjunctive cerclage wire fixation for the prevention of periprosthetic femur fractures using cementless press-fit total hip replacement.

    Science.gov (United States)

    Christopher, Scott A; Kim, Stanley E; Roe, Simon; Pozzi, Antonio

    2016-08-01

    Periprosthetic femoral fractures are a common complication associated with cementless press-fit total hip arthroplasty. The use of prophylactic cerclage wire fixation has been advocated to reduce this complication. The objective of this study was to evaluate whether a double loop cerclage wire, used as adjunctive fixation, increased the peak torsional load to failure in femora implanted with press-fit cementless stems. Peak torsional load to failure was compared between femora without adjunctive fixation and femora receiving a 1 mm double loop cerclage wire placed proximally to the lesser trochanter. Femora treated with adjunctive cerclage wire fixation failed at 20% greater peak torque (P = 0.0001). In conclusion, a double loop cerclage wire may aid in the prevention of periprosthetic fractures associated with press-fit cementless femoral stems. PMID:27387718

  16. Highly Porous Carbon Derived from MOF-5 as a Support of ORR Electrocatalysts for Fuel Cells.

    Science.gov (United States)

    Khan, Inayat Ali; Qian, Yuhong; Badshah, Amin; Nadeem, Muhammad Arif; Zhao, Dan

    2016-07-13

    The development of highly competent electrocatalysts for the sluggish oxygen reduction reaction (ORR) at cathodes of proton-exchange membrane fuel cells (PEMFCs) is extremely important for their long-term operation and wide applications. Herein, we present highly efficient ORR electrocatalysts based on Pt/Ni bimetallic nanoparticles dispersed on highly porous carbon obtained via pyrolysis of a metal-organic framework MOF-5. In comparison to the commercial Pt/C (20%), the electrocatalyst Pt-Ni/PC 950 (15:15%) in this study exhibits a pronounced positive shift of 90 mV in Eonset. In addition, it also demonstrates excellent long-term stability and durability during the 500-cycle continue-oxygen-supply (COS) accelerating durability tests (ADTs). The significantly improved activity and stability of Pt-Ni/PC 950 (15:15%) can be attributed to the Pt electron interaction with Ni and carbon support as has been proved in X-ray and microscopic analysis.

  17. Effect of sintering temperature on structure and properties of highly porous glass-ceramics

    Directory of Open Access Journals (Sweden)

    Artem Iatsenko

    2015-06-01

    Full Text Available Highly porous biomaterials with a structure close to that of cancellous bone have been prepared using biogenic hydroxyapatite and glass of the SiO2-Na2O-CaO system by a replication of the polymer template structure. It has been established that during sintering of the samples the hydroxyapatite decomposes, which involves the formation of glass-ceramics containing phases of renanit NaCaPO4, calcium phosphate silicate Ca5(PO42SiO4, calcium pyrophosphate Ca2P2O7 and impurities of hydroxyapatite Ca5(PO43(OH. Structural characteristics and mechanical properties of the obtained materials are promising for the replacement of defective cancellous bone.

  18. Variational Multiscale Finite Element Method for Flows in Highly Porous Media

    KAUST Repository

    Iliev, O.

    2011-10-01

    We present a two-scale finite element method (FEM) for solving Brinkman\\'s and Darcy\\'s equations. These systems of equations model fluid flows in highly porous and porous media, respectively. The method uses a recently proposed discontinuous Galerkin FEM for Stokes\\' equations by Wang and Ye and the concept of subgrid approximation developed by Arbogast for Darcy\\'s equations. In order to reduce the "resonance error" and to ensure convergence to the global fine solution, the algorithm is put in the framework of alternating Schwarz iterations using subdomains around the coarse-grid boundaries. The discussed algorithms are implemented using the Deal.II finite element library and are tested on a number of model problems. © 2011 Society for Industrial and Applied Mathematics.

  19. Protein growth factors loaded highly porous chitosan scaffold: A comparison of bone healing properties

    Energy Technology Data Exchange (ETDEWEB)

    Nandi, Samit K., E-mail: samitnandi1967@gmail.com [Department of Veterinary Surgery and Radiology, West Bengal University of Animal and Fishery Sciences, Kolkata (India); Kundu, Biswanath, E-mail: biswa_kundu@rediffmail.com [Bioceramics and Coating Division, CSIR—Central Glass and Ceramic Research Institute, Kolkata (India); Basu, Debabrata [Bioceramics and Coating Division, CSIR—Central Glass and Ceramic Research Institute, Kolkata (India)

    2013-04-01

    Present study aimed to investigate and compare effectiveness of porous chitosan alone and in combination with insulin like growth factor-1 (IGF-1) and bone morphogenetic protein-2 (BMP-2) in bone healing. Highly porous (85 ± 2%) with wide distribution of macroporous (70–900 μm) chitosan scaffolds were fabricated as bone substitutes by employing a simple liquid hardening method using 2% (w/v) chitosan suspension. IGF-1 and BMP-2 were infiltrated using vacuum infiltration with freeze drying method. Adsorption efficiency was found to be 87 ± 2 and 90 ± 2% for BMP-2 and IGF-1 respectively. After thorough material characterization (pore details, FTIR and SEM), samples were used for subsequent in vivo animal trial. Eighteen rabbit models were used to evaluate and compare control (chitosan) (group A), chitosan with IGF-1 (group B) and chitosan with BMP-2 (group C) in the repair of critical size bone defect in tibia. Radiologically, there was evidence of radiodensity in defect area from 60th day (initiated on 30th day) in groups B and C as compared to group A and attaining nearly bony density in most of the part at day 90. Histological results depicted well developed osteoblastic proliferation around haversian canal along with proliferating fibroblast, vascularization and reticular network which was more pronounced in group B followed by groups C and A. Fluorochrome labeling and SEM studies in all groups showed similar outcome. Hence, porous chitosan alone and in combination with growth factors (GFs) can be successfully used for bone defect healing with slight advantage of IGF-1 in chitosan samples. - Highlights: ► Fabrication and characterization of porous chitosan with or without IGF-1 and BMP-2 ► Highly porous growth factor loaded chitosan studied in animal subjects for 3 months ► Parameters studied: histopathology, radiology and fluorochrome labeling ► IGF-1 loaded porous chitosan found to be very effective for bone defect healing.

  20. Protein growth factors loaded highly porous chitosan scaffold: A comparison of bone healing properties

    International Nuclear Information System (INIS)

    Present study aimed to investigate and compare effectiveness of porous chitosan alone and in combination with insulin like growth factor-1 (IGF-1) and bone morphogenetic protein-2 (BMP-2) in bone healing. Highly porous (85 ± 2%) with wide distribution of macroporous (70–900 μm) chitosan scaffolds were fabricated as bone substitutes by employing a simple liquid hardening method using 2% (w/v) chitosan suspension. IGF-1 and BMP-2 were infiltrated using vacuum infiltration with freeze drying method. Adsorption efficiency was found to be 87 ± 2 and 90 ± 2% for BMP-2 and IGF-1 respectively. After thorough material characterization (pore details, FTIR and SEM), samples were used for subsequent in vivo animal trial. Eighteen rabbit models were used to evaluate and compare control (chitosan) (group A), chitosan with IGF-1 (group B) and chitosan with BMP-2 (group C) in the repair of critical size bone defect in tibia. Radiologically, there was evidence of radiodensity in defect area from 60th day (initiated on 30th day) in groups B and C as compared to group A and attaining nearly bony density in most of the part at day 90. Histological results depicted well developed osteoblastic proliferation around haversian canal along with proliferating fibroblast, vascularization and reticular network which was more pronounced in group B followed by groups C and A. Fluorochrome labeling and SEM studies in all groups showed similar outcome. Hence, porous chitosan alone and in combination with growth factors (GFs) can be successfully used for bone defect healing with slight advantage of IGF-1 in chitosan samples. - Highlights: ► Fabrication and characterization of porous chitosan with or without IGF-1 and BMP-2 ► Highly porous growth factor loaded chitosan studied in animal subjects for 3 months ► Parameters studied: histopathology, radiology and fluorochrome labeling ► IGF-1 loaded porous chitosan found to be very effective for bone defect healing

  1. Primary Stability Recognition of the Newly Designed Cementless Femoral Stem Using Digital Signal Processing

    Science.gov (United States)

    Salleh, Sh-Hussain; Hamedi, Mahyar; Zulkifly, Ahmad Hafiz; Lee, Muhammad Hisyam; Mohd Noor, Alias; Harris, Arief Ruhullah A.; Abdul Majid, Norazman

    2014-01-01

    Stress shielding and micromotion are two major issues which determine the success of newly designed cementless femoral stems. The correlation of experimental validation with finite element analysis (FEA) is commonly used to evaluate the stress distribution and fixation stability of the stem within the femoral canal. This paper focused on the applications of feature extraction and pattern recognition using support vector machine (SVM) to determine the primary stability of the implant. We measured strain with triaxial rosette at the metaphyseal region and micromotion with linear variable direct transducer proximally and distally using composite femora. The root mean squares technique is used to feed the classifier which provides maximum likelihood estimation of amplitude, and radial basis function is used as the kernel parameter which mapped the datasets into separable hyperplanes. The results showed 100% pattern recognition accuracy using SVM for both strain and micromotion. This indicates that DSP could be applied in determining the femoral stem primary stability with high pattern recognition accuracy in biomechanical testing. PMID:24800230

  2. Primary stability recognition of the newly designed cementless femoral stem using digital signal processing.

    Science.gov (United States)

    Baharuddin, Mohd Yusof; Salleh, Sh-Hussain; Hamedi, Mahyar; Zulkifly, Ahmad Hafiz; Lee, Muhammad Hisyam; Mohd Noor, Alias; Harris, Arief Ruhullah A; Abdul Majid, Norazman

    2014-01-01

    Stress shielding and micromotion are two major issues which determine the success of newly designed cementless femoral stems. The correlation of experimental validation with finite element analysis (FEA) is commonly used to evaluate the stress distribution and fixation stability of the stem within the femoral canal. This paper focused on the applications of feature extraction and pattern recognition using support vector machine (SVM) to determine the primary stability of the implant. We measured strain with triaxial rosette at the metaphyseal region and micromotion with linear variable direct transducer proximally and distally using composite femora. The root mean squares technique is used to feed the classifier which provides maximum likelihood estimation of amplitude, and radial basis function is used as the kernel parameter which mapped the datasets into separable hyperplanes. The results showed 100% pattern recognition accuracy using SVM for both strain and micromotion. This indicates that DSP could be applied in determining the femoral stem primary stability with high pattern recognition accuracy in biomechanical testing. PMID:24800230

  3. Primary Stability Recognition of the Newly Designed Cementless Femoral Stem Using Digital Signal Processing

    Directory of Open Access Journals (Sweden)

    Mohd Yusof Baharuddin

    2014-01-01

    Full Text Available Stress shielding and micromotion are two major issues which determine the success of newly designed cementless femoral stems. The correlation of experimental validation with finite element analysis (FEA is commonly used to evaluate the stress distribution and fixation stability of the stem within the femoral canal. This paper focused on the applications of feature extraction and pattern recognition using support vector machine (SVM to determine the primary stability of the implant. We measured strain with triaxial rosette at the metaphyseal region and micromotion with linear variable direct transducer proximally and distally using composite femora. The root mean squares technique is used to feed the classifier which provides maximum likelihood estimation of amplitude, and radial basis function is used as the kernel parameter which mapped the datasets into separable hyperplanes. The results showed 100% pattern recognition accuracy using SVM for both strain and micromotion. This indicates that DSP could be applied in determining the femoral stem primary stability with high pattern recognition accuracy in biomechanical testing.

  4. Failure of Polyethylene Inlays in Cementless Total Hip Arthroplasty: A Retrieval Analysis

    Directory of Open Access Journals (Sweden)

    Ulrike Mueller

    2016-01-01

    Full Text Available A retrieval analysis has been performed on 50 polyethylene inlays of cementless screw ring implants (Mecring, Mecron, Berlin, Germany to investigate the failure mechanism of this specific open cup hip arthroplasty design that has shown a high clinical failure rate. Design-specific damage modes like rim creep, collar fatigue, and backside wear were assessed. Furthermore, the inlays were measured using a CMM to determine deformation. In 90% backside wear was observed and collar fatigue occurred in 68% of the cases. Rim creep was present in 38% of the polyethylene inlays. In 90% of the cases the cup opening diameter was 32.1 mm or less and 46% had a diameter less than 32 mm. It seems that creep and deformation of the polyethylene leads to a reduced diameter at the cup opening and consequently decreased clearance. To avoid this type of failure, polyethylene inlays should be supported at the back by the cup to reduce the risk of ongoing creep deformation.

  5. New titanium and titanium/hydroxyapatite coatings on ultra-high-molecular-weight polyethylene-in vitro osteoblastic performance

    Energy Technology Data Exchange (ETDEWEB)

    Silva, M A; Lopes, M A; Santos, J D; Fernandes, M H [Department of Metallurgical and Materials Engineering, Materials Section-Faculty of Engineering, University of Porto (Portugal); Gomes, P S [Laboratory of Pharmacology and Cellular Biocompatibility-Faculty of Dental Medicine, University of Porto (Portugal); Vila, M; Silva, R F, E-mail: mhfernandes@fmd.up.p [Department of Ceramics and Glass Engineering, University of Aveiro, CICECO (Portugal)

    2010-06-15

    The development of optimized hip joint materials is one of the most challenging opportunities in prosthetic technologies. In current approaches, ultra-high-molecular-weight polyethylene (UHMWPE) has been a favorite material for the acetabular component and, regarding the cementless technique, several coating options may be considered to contain and stabilize bearing surfaces and establish an improved interface with bone. In this work, newly developed constructs of UHMWPE coated with either commercially pure titanium (cpTi-UHMWPE), by DC magnetron sputtering, or with commercially pure titanium and hydroxyapatite (cpTi/HA-UHMWPE), by DC/RF magnetron co-sputtering, have been prepared and biologically characterized with human bone marrow-derived osteoblastic cultures. The cpTi-UHMWPE samples allowed a high cell growth and the expression of the complete osteoblastic phenotype, with high alkaline phosphatase activity, expression of osteogenic-associated genes and evident cell-mediated mineralization of the extracellular matrix. In comparison, the cpTi/HA-UHMWPE samples reported lower cell proliferation but earlier cell-mediated matrix mineralization. Accordingly, these newly developed systems may be suitable candidates to improve the osteointegration process in arthroplastic devices; nevertheless, further biological evaluation should be conducted.

  6. A multicenter approach evaluating the impact of vitamin E-blended polyethylene in cementless total hip replacement

    Directory of Open Access Journals (Sweden)

    Marcus Jäger

    2014-04-01

    Full Text Available Since polyethylene is one of the most frequently used biomaterials as a liner in total hip arthroplasty, strong efforts have been made to improve design and material properties over the last 50 years. Antioxidants seems to be a promising alternative to further increase durability and reduce polyethylene wear in long term. As of yet, only in vitro results are available. While they are promising, there is yet no clinical evidence that the new material shows these advantages in vivo. To answer the question if vitamin-E enhanced ultra-high molecular weight polyethylene (UHMWPE is able to improve long-term survivorship of cementless total hip arthroplasty we initiated a randomized long-term multicenter trial. Designed as a superiority study, the oxidation index assessed in retrieval analyses of explanted liners was chosen as primary parameter. Radiographic results (wear rate, osteolysis, radiolucency and functional outcome (Harris Hip Scores, University of California-Los Angeles, Hip Disability and Osteoarthritis Outcome Score, Visual Analogue Scale will serve as secondary parameters. Patients with the indication for a cementless total hip arthroplasty will be asked to participate in the study and will be randomized to either receive a standard hip replacement with a highly cross-linked UHMWPE-X liner or a highly cross-linked vitamin-E supplemented UHMWPE-XE liner. The follow-up will be 15 years, with evaluation after 5, 10 and 15 years. The controlled randomized study has been designed to determine if Vitamin-E supplemented highly cross-linked polyethylene liners are superior to standard XLPE liners in cementless total hip arthroplasty. While several studies have been started to evaluate the influence of vitamin-E, most of them evaluate wear rates and functional results. The approach used for this multicenter study, to analyze the oxidation status of retrieved implants, should make it possible to directly evaluate the ageing process and development

  7. Heat and Mass Transfer in a High-Porous Low-Temperature Thermal Insulation in Real Operating Conditions

    Directory of Open Access Journals (Sweden)

    Polovnikov Vyacheslav Yu.

    2015-01-01

    Full Text Available The results of numerical simulation of heat and mass transfer in a high-porous low-temperature insulation in conditions of insulation freezing, a moisture migration to the front of phase transition and a condensation forming on an outer contour of interaction were obtained. Values of heat leakage were established.

  8. Total hip arthroplasty with cementless cups and femoral head autografts for patients with hip dysplasia and osteoarthritis

    Institute of Scientific and Technical Information of China (English)

    吴立东; 金礼斌; 严世贵; 杨泉森; 戴雪松; 王祥华

    2004-01-01

    Objective:To evaluate the outcome of total hip arthroplasty (THA) with cementless cups and femoral head autografts for patients with hip dysplasia and osteoarthritis.Methods: Between 1995 and 2002, we implanted 23cementless cups and femoral head autografts in 20 patients with hip dysplasia and osteoarthritis. In this study, a retrospective study was made on 21 hips in 20 patients (18females and 2 males, aged 50 years on an average) with developmental hip dysplasia treated by THA with acementless cup and femoral head autograft. The acetabular cup was placed at the level of the true acetabuinm and all the patients required autogenous femoral head grafts due to acetabular deficiency. The average rate of the acetabular cup covered by the femoral head autograft was 31%(ranging from 10% to 45%). Eight hips had less than 25%cup coverage and thirteen between 25% and 50%. The average follow-up period was 4.7 years (range, 1-8 years).The replacing outcome was evaluated by modified Harris hip score. Preoperative and follow-up radiographs were made.Results: All the autografts were united to the host bones. No autograft was collapsed or no component from the hip was loosed in all the patients. According to the modified Harris hip score, the average hip score increased from 46 before operation to 89 at the final review. Before operation, the leg-length discrepancy was greater than 2 cm in all the patients except one with bilateral hip dysplasia.After operation, only 2 out of 20 patients had a leg-length discrepancy greater than 1 cm. Three hips showed minor bone resorption in the lateral portion of the graft, which did not support the cup. Three hips developed Grade 1Brooker heterotopic ossification and one developed Grade 2.Conclusions: THA with a cementless cup and a femoral head autograft for patients with osteoarthritis resulted from hip dysplasia can result in favorable outcomes. This method can provide reliable acetabular fixation and restore the acetabular bone stock in

  9. Expanded organic building units for the construction of highly porous metal-organic frameworks.

    Science.gov (United States)

    Kong, Guo-Qiang; Han, Zhi-Da; He, Yabing; Ou, Sha; Zhou, Wei; Yildirim, Taner; Krishna, Rajamani; Zou, Chao; Chen, Banglin; Wu, Chuan-De

    2013-10-25

    Two new organic building units that contain dicarboxylate sites for their self-assembly with paddlewheel [Cu2(CO2)4] units have been successfully developed to construct two isoreticular porous metal-organic frameworks (MOFs), ZJU-35 and ZJU-36, which have the same tbo topologies (Reticular Chemistry Structure Resource (RCSR) symbol) as HKUST-1. Because the organic linkers in ZJU-35 and ZJU-36 are systematically enlarged, the pores in these two new porous MOFs vary from 10.8 Å in HKUST-1 to 14.4 Å in ZJU-35 and 16.5 Å in ZJU-36, thus leading to their higher porosities with Brunauer-Emmett-Teller (BET) surface areas of 2899 and 4014 m(2) g(-1) for ZJU-35 and ZJU-36, respectively. High-pressure gas-sorption isotherms indicate that both ZJU-35 and ZJU-36 can take up large amounts of CH4 and CO2, and are among the few porous MOFs with the highest volumetric storage of CH4 under 60 bar and CO2 under 30 bar at room temperature. Their potential for high-pressure swing adsorption (PSA) hydrogen purification was also preliminarily examined and compared with several reported MOFs, thus indicating the potential of ZJU-35 and ZJU-36 for this important application. Studies show that most of the highly porous MOFs that can volumetrically take up the greatest amount of CH4 under 60 bar and CO2 under 30 bar at room temperature are those self-assembled from organic tetra- and hexacarboxylates that contain m-benzenedicarboxylate units with the [Cu2(CO2)4] units, because this series of MOFs can have balanced porosities, suitable pores, and framework densities to optimize their volumetric gas storage. The realization of the two new organic building units for their construction of highly porous MOFs through their self-assembly with [Cu2(CO2)4] units has provided great promise for the exploration of a large number of new tetra- and hexacarboxylate organic linkers based on these new organic building units in which different aromatic backbones can be readily incorporated

  10. The dimensional accuracy of preparation of femoral cavity in cementless total hip arthroplasty

    Institute of Scientific and Technical Information of China (English)

    WU Li-dong (吴立东); HAHNE H.J.; HASSENPFLUG J.

    2004-01-01

    Objective: To observe the accuracy of femoral preparation and the position of the cementless prosthesis in femoral cavity, and to compare the results between the computer-assisted surgical group (CASPAR) and the conventional group. Methods: Ten femoral components were implanted either manually or by CASPAR in cadaver femurs. The specimens were cut to 3 mm thick slices. Microradiograms of every slice were sent to a computer for analysis with special software (IDL). The gaps and the medullary cavities between component and bone, the direct bone contact area of the implant surface,the gap width and the percentage of gap and bone contact area were measured in every slice. Results: In the proximal implant coated with HA of the CASPAR group, the average percentage of bone contact reached 93.2% (ranging from 87.6% to 99.7%); the average gap percentage was 2.9% (ranging from 0.3% to 7.8%); the maximum gap width was 0.81 mm and the average gap width was only 0.20 mm. While in the conventional group, the average percentage of bone contact reached 60.1% (ranging from 49.2% to 70.4%); the average gap percentage was 32.8% (ranging from 25.1% to 39.9%); the maximum gap width was 2.97 mm and the average gap width was 0.77 mm. The average gap around the implant in the CASPAR group was only 9% of that in the manual group; the maximum and average gap widths were only about 26% of those in the manual group. On the other hand, the CASPAR group showed 33% higher bone contact than the manual group. Conclusion: With the use of robotics-assisted system, significant progress can be achieved for femoral preparation in total hip arthroplasty.

  11. The dimensional accuracy of preparation of femoral cavity in cementless total hip arthroplasty

    Institute of Scientific and Technical Information of China (English)

    吴立东; HAHNEH.J.; HASSENPFLUGJ.

    2004-01-01

    Objective: To observe the accuracy of femoral preparation and the position of the cementless prosthesis in femoral cavity, and to compare the results between the computer-assisted surgical group (CASPAR) and the conventional group. Methods: Ten femoral components were implanted either manually or by CASPAR in cadaver femurs. The specimens were cut to 3mm thick slices. Microradiograms of every slice were sent to a computer for analysis with special software (IDL). The gaps and the medullary cavities between component and bone, the direct bone contact area of the implant surface, the gap width and the percentage of gap and bone contact area were measured in every slice. Results: In the proximal implant coated with HA of the CASPAR group, the average percentage of bone contact reached 93.2% (ranging from 87.6% to 99.7%); the average gap percentage was 2.9% (ranging from 0.3% to 7.8%); the maximum gap width was 0.81mm and the average gap width was only 0.20mm. While in the conventional group, the average percentage of bone contact reached 60.1% (ranging from 49.2% to 70.4%); the average gap percentage was 32.8% (ranging from 25.1% to 39.9%); the maximum gap width was 2.97mm and the average gap width was 0.77mm. The average gap around the implant in the CASPAR group was only 9% of that in the manual group; the maximum and average gap widths were only about 26% of those in the manual group. On the other hand, the CASPAR group showed 33% higher bone contact than the manual group. Conclusion: With the use of robotics-assisted system, significant progress can be achieved for femoral preparation in total hip arthroplasty.

  12. Structure of a designed protein cage that self-assembles into a highly porous cube

    Science.gov (United States)

    Lai, Yen-Ting; Reading, Eamonn; Hura, Greg L.; Tsai, Kuang-Lei; Laganowsky, Arthur; Asturias, Francisco J.; Tainer, John A.; Robinson, Carol V.; Yeates, Todd O.

    2014-12-01

    Natural proteins can be versatile building blocks for multimeric, self-assembling structures. Yet, creating protein-based assemblies with specific geometries and chemical properties remains challenging. Highly porous materials represent particularly interesting targets for designed assembly. Here, we utilize a strategy of fusing two natural protein oligomers using a continuous alpha-helical linker to design a novel protein that self assembles into a 750 kDa, 225 Å diameter, cube-shaped cage with large openings into a 130 Å diameter inner cavity. A crystal structure of the cage showed atomic-level agreement with the designed model, while electron microscopy, native mass spectrometry and small angle X-ray scattering revealed alternative assembly forms in solution. These studies show that accurate design of large porous assemblies with specific shapes is feasible, while further specificity improvements will probably require limiting flexibility to select against alternative forms. These results provide a foundation for the design of advanced materials with applications in bionanotechnology, nanomedicine and material sciences.

  13. Research of Porization and Adsorptions in High-Porous Adsorptive Layers of Vermiculite

    Directory of Open Access Journals (Sweden)

    K. Syrmanova

    2016-06-01

    Full Text Available Adsorption capacity of the adsorbent is dependent on the concentration of the substance in the liquid or vapor phase, its partial pressure, temperature, and the initial state of the adsorbent. At the swelling a cellular porous structure is formed, total porosity that connects with the entered number and the content of the gaseous component masses. The rheological characteristics of porous masses have the decisive effect on the porous structure. Common state for all versions of swelling is a plastic-viscous porous mass condition during their porization. The interlayer structure and inter-packet intervals may be considered as vermiculite plate micropores with dimensions of 0.3 – 1.2 nm. Vermiculite cation exchange capacity is in the range of 100-150 mEq / 100 g, i.e. from clay minerals it is one of the most interchangeable. The research results of the internal structure of adsorption layers by the adsorption isotherms means indicative of the internal surface of the porous layer is characterized by an extremely complex and developed form and can be described by means of fractal geometry. A model of the geometric structure of mica materials formed in the process of blistering during heat treatment is developed. The presented model has sufficiently general form and can be used both in the organization of systematic experimental studies of porization and adsorption in the adsorption layers of highly porous, and for the porization vermiculite optimization.

  14. Highly porous nickel oxide thin films prepared by a hydrothermal synthesis method for electrochromic application

    Science.gov (United States)

    Chen, Z.; Xiao, A.; Chen, Y.; Zuo, C.; Zhou, S.; Li, L.

    2013-11-01

    We report NiO nanowall thin films prepared by a facile hydrothermal synthesis method and their electrochromic application. The as-prepared porous nanowall NiO thin films show a highly porous structure built up by many interconnected nanoflakes with a thickness of about 30 nm. The electrochromic performances of the NiO films are characterized by means of UV-vis spectroscopy and cyclic voltammetry (CV) measurements. The effect of the annealing temperature on electrochromic properties is discussed. The NiO nanowall film annealed at 300 °C exhibits much better electrochromic performance than those counterparts annealed at higher temperature. The film annealed at 300 °C exhibits a noticeable electrochromism with reversible color changes from transparent to brown dark and presents a transmittance variation with 77% at 550 nm. The NiO nanowall film also shows good reaction kinetics with fast switching speed, and the coloration and bleaching times are 3 s and 4 s, respectively. The improved electrochromic performances are due to the porous morphological characteristics with fast ion and electron transfer resulting in fast reaction kinetics and high color contrast.

  15. Highly porous activated carbons prepared from carbon rich Mongolian anthracite by direct NaOH activation

    Science.gov (United States)

    Byamba-Ochir, Narandalai; Shim, Wang Geun; Balathanigaimani, M. S.; Moon, Hee

    2016-08-01

    Highly porous activated carbons (ACs) were prepared from Mongolian raw anthracite (MRA) using sodium hydroxide as an activation agent by varying the mass ratio (powdered MRA/NaOH) as well as the mixing method of chemical agent and powdered MRA. The specific BET surface area and total pore volume of the prepared MRA-based activated carbons (MACs) are in the range of 816-2063 m2/g and of 0.55-1.61 cm3/g, respectively. The pore size distribution of MACs show that most of the pores are in the range from large micropores to small mesopores and their distribution can be controlled by the mass ratio and mixing method of the activating agent. As expected from the intrinsic property of the MRA, the highly graphitic surface morphology of prepared carbons was confirmed from Raman spectra and transmission electron microscopy (TEM) studies. Furthermore the FTIR and XPS results reveal that the preparation of MACs with hydrophobic in nature is highly possible by controlling the mixing conditions of activating agent and powdered MRA. Based on all the results, it is suggested that the prepared MACs could be used for many specific applications, requiring high surface area, optimal pore size distribution, proper surface hydrophobicity as well as strong physical strength.

  16. Treatment of Hip Dysplasia in a Dog after a Failed Triple Pelvic Osteotomy with a Zurich Cementless Total Hip Replacement

    Directory of Open Access Journals (Sweden)

    SY Heo and H.B Lee*

    2013-07-01

    Full Text Available An Alaskan Malamute (2-year-old, castrated male, 41kg was referred with bilateral hind limb lameness. The dog had a history of a bilateral triple pelvic osteotomy (TPO to correct hip dysplasia one year previously, a surgery that was unsuccessful. On physical examination, pain and crepitus were noted in both hip joints. There was hip joint subluxation and mild degenerative changes bilaterally seen by radiograph. A Zurich cementless total hip replacement (ZCTHR was planned for the right hind limb. After a craniolateral approach, an acetabular cup and a cementless femoral stem were implanted. The femoral head was placed in the femoral stem, and the prosthetic joint was then reduced. At a 9 month postoperative checkup, there was no pain on palpation or manipulation of the right pelvic limb, and the range of motion was within normal limits. On radiological examination, there was no implant loosening. The ZCTHR can thus be applied in a failed TPO patient as a revision surgery.

  17. Growth Assisted by Glancing Angle Deposition: A New Technique to Fabricate Highly Porous Anisotropic Thin Films.

    Science.gov (United States)

    Sanchez-Valencia, Juan Ramon; Longtin, Remi; Rossell, Marta D; Gröning, Pierangelo

    2016-04-01

    We report a new methodology based on glancing angle deposition (GLAD) of an organic molecule in combination with perpendicular growth of a second inorganic material. The resulting thin films retain a very well-defined tilted columnar microstructure characteristic of GLAD with the inorganic material embedded inside the columns. We refer to this new methodology as growth assisted by glancing angle deposition or GAGLAD, since the material of interest (here, the inorganic) grows in the form of tilted columns, though it is deposited under a nonglancing configuration. As a "proof of concept", we have used silver and zinc oxide as the perpendicularly deposited material since they usually form ill-defined columnar microstructures at room temperature by GLAD. By means of our GAGLAD methodology, the typical tilted columnar microstructure can be developed for materials that otherwise do not form ordered structures under conventional GLAD. This simple methodology broadens significantly the range of materials where control of the microstructure can be achieved by tuning the geometrical deposition parameters. The two examples presented here, Ag/Alq3 and ZnO/Alq3, have been deposited by physical vapor deposition (PVD) and plasma enhanced chemical vapor deposition (PECVD), respectively: two different vacuum techniques that illustrate the generality of the proposed technique. The two type of hybrid samples present very interesting properties that demonstrate the potentiality of GAGLAD. On one hand, the Ag/Alq3 samples present highly optical anisotropic properties when they are analyzed with linearly polarized light. To our knowledge, these Ag/Alq3 samples present the highest angular selectivity reported in the visible range. On the other hand, ZnO/Alq3 samples are used to develop highly porous ZnO thin films by using Alq3 as sacrificial material. In this way, antireflective ZnO samples with very low refractive index and extinction coefficient have been obtained. PMID:26954074

  18. Titanium and titanium alloys fundamentals and applications

    CERN Document Server

    Peters, Manfred

    2003-01-01

    This handbook is an excellent reference for materials scientists and engineers needing to gain more knowledge about these engineering materials. Following introductory chapters on the fundamental materials properties of titanium, readers will find comprehensive descriptions of the development, processing and properties of modern titanium alloys. There then follows detailed discussion of the applications of titanium and its alloys in aerospace, medicine, energy and automotive technology.

  19. Chinese titanium industry

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    <正>The effects of the financial crisis on the titanium industry are visible: investment plans for titanium smelting and processing have basically come to a halt in 2009, and projects under construction were also delayed. However, the

  20. Titanium hermetic seals

    Science.gov (United States)

    Brow, Richard K.; Watkins, Randall D.

    1995-01-01

    Titanium is prenitrided by being heated in a nitrogen environment under conditions which give rise to the formation of a titanium-nitride surface layer on the titanium. Titanium thus prenitrided may be used in electrical components which are hermetically sealed using silicate glasses and standard glass sealing techniques. According to the method of the invention, alkali volatilization and formation of deleterious interfacial silicide are inhibited.

  1. Delayed cementless total hip arthroplasty for neglected dislocation of hip combined with complex acetabular fracture and deficient bone stock

    Directory of Open Access Journals (Sweden)

    Gavaskar Ashok S

    2012-12-01

    Full Text Available 【Abstract】Total hip arthroplasty (THA for an un-treated acetabular fracture is technically challenging and the long-term result is not so favorable. A 45-year-old fe-male patient with untreated column and comminuted poste-rior wall fracture of the acetabulum was treated in our insti-tution by reconstruction of the posterior wall using iliac strut autograft and plate stabilization of the posterior col-umn with cancellous grafting and cementless THA in a single stage. At 3 years’ follow-up, the patient was independently mobile without limb length discrepancy. Radiological evalu-ation showed well integrated components and bone grafts. No evidence of aseptic loosening or osteolysis was found. This report aims to emphasize that bony acetabular recon-struction allows the use of primary hip components, which improves prosthesis longevity and preserves bone stock for a future revision. Key words: Acetabulum; Fractures, bone; Hip dislocation; Arthroplasty, replacement, hip

  2. Delayed cementless total hip arthroplasty for neglected dislocation of hip combined with complex acetabular fracture and deficient bone stock

    Institute of Scientific and Technical Information of China (English)

    Ashok S Gavaskar; Naveen Chowdary Tummala

    2012-01-01

    Total hip arthroplasty (THA) for an untreated acetabular fracture is technically challenging and the long-term result is not so favorable.A 45-year-old female patient with untreated column and comminuted posterior wall fracture of the acetabulum was treated in our institution by reconstruction of the posterior wall using iliac strut autograft and plate stabilization of the posterior column with cancellous grafting and cementless THA in a single stage.At 3 years' follow-up,the patient was independently mobile without limb length discrepancy.Radiological evaluation showed well integrated components and bone grafts.No evidence of aseptic loosening or osteolysis was found.This report aims to emphasize that bony acetabular reconstruction allows the use of primary hip components,which improves prosthesis longevity and preserves bone stock for a future revision.

  3. Titanium condenser tubes

    International Nuclear Information System (INIS)

    The corrosion resistance of titanium in sea water is extremely excellent, but titanium tubes are expensive, and the copper alloy tubes resistant in polluted sea water were developed, therefore they were not used practically. In 1970, ammonia attack was found on the copper alloy tubes in the air-cooled portion of condensers, and titanium tubes have been used as the countermeasure. As the result of the use, the galvanic attack an copper alloy tube plates with titanium tubes as cathode and the hydrogen absorption at titanium tube ends owing to excess electrolytic protection were observed, but the corrosion resistance of titanium tubes was perfect. These problems can be controlled by the application of proper electrolytic protection. The condensers with all titanium tubes adopted recently in USA are intended to realize perfectly no-leak condensers as the countermeasure to the corrosion in steam generators of PWR plants. Regarding large condensers of nowadays, three problems are pointed out, namely the vibration of condenser tubes, the method of joining tubes and tube plates, and the tubes of no coolant leak. These three problems in case of titanium tubes were studied, and the problem of the fouling of tubes was also examined. The intervals of supporting plates for titanium tubes should be narrowed. The joining of titanium tubes and titanium tube plates by welding is feasible and promising. The cleaning with sponge balls is effective to control fouling. (Kako, I.)

  4. Surface protection treatments of highly porous building stones and sustainability problems

    Science.gov (United States)

    Calia, Angela; Lettieri, Maria Teresa; Matera, Loredana; Sileo, Maria

    2013-04-01

    The growing attention to the cultural value and the potential touristic attraction of the historic towns has led to increasing activities of rehabilitation and conservation of the historical built heritage. Chemical treatments have become a common practice for the protection of the stone building surface against the decay agents and traditional methods of protection, such as the application of sacrificial layers, have been even more neglected. The use of chemical products on large scale works on the historical built heritage draws the attention towards the sustainability of the conservation treatments, that involve peculiar features with relation to the different types of stones. Sustainability is undoubtedly in terms of human and environmental impact of the used products, so that the use of new formulations based on aqueous solvent should be preferred. Sustainability also means the equilibrium between the required performances of the treatments and the preservation of the original stone properties (colour, permeability, etc), namely harmlessness and effectiveness of the treatments. This can be a critical aspect when we deal with very porous stones, namely having porosity between 30-40%, that are widely used in many countries as traditional building materials. In most cases no information - or very general recommendations - is reported in the technical sheets of the conservation products with reference to the application to these types of stones. Relevant problems of compatibility can arise from the significant amounts absorbed by the high porous structure, as well as in terms of cost effectiveness of the treatments. In this work several calcarenites with different petro-physic characteristics and porosity between 30 and 45% are concerned for the assessment of the performance of two commercial water based products for stone protection, respectively an alcoxy-siloxane with low molecular weight and a modified organo-silane. This activity is a part of the Apulia

  5. Pore Network Modeling of Drainage and Imbibition in Highly Porous Media

    Science.gov (United States)

    Riasi, S.; Huang, G.; Montemagno, C.; Yeghiazarian, L.

    2012-12-01

    Several macro- and micro-scale approaches have been used in multiphase flow modeling in porous media. Among different micro-scale models, pore network modeling is known as a computationally efficient and algorithmically simple model. The critical step in pore network modeling is to extract a pore network, which represents the void space structure and consist of pore bodies and throats. Pore bodies are key contributors to the so-called geometrical hysteresis in the capillary pressure-saturation curves, through gradual pore body filling during imbibition. Gradual pore body filling depends on the geometry of pore bodies and on the coordination number, i.e. the number of pore throats connected to the pore body. In previous studies, researchers used analytical solutions for gradual pore body filling, typically assuming that the wetting phase invades the pore body only through one pore throat. Another limitation is the fixed coordination number. We removed these limitations in this study. We have developed a 2D quasi-static pore network model for drainage and imbibition in a 95%-porous nonwoven fiber structure. Since in unstructured highly porous media large void spaces are not distinctly separated, defining specific pore bodies is cumbersome. In order to solve this problem we propose a new strategy to define the pore network, where we employed the medial axis transform and skeletonization to find the medial axis of the void space. A continuous medial axis is determined using the swelling algorithm, a new fast and simple pixel-based distance transform algorithm. We have defined the pore network as a network of pores along this medial axis, with the radius equal to the local perpendicular distance between the medial axis and solid phase. Therefore, in the resulting pore network, instead of having pore bodies and throats of predetermined and fixed geometry, we employ variable pore radii that obey the exact topology of porous structure. There are several advantages to using

  6. Highly porous magnetite/graphene nanocomposites for a solid-state electrochemiluminescence sensor on paper-based chips.

    Science.gov (United States)

    Xu, Yuanhong; Lv, Zhaozi; Xia, Yong; Han, Yanchao; Lou, Baohua; Wang, Erkang

    2013-04-01

    Graphene-nanosheet-based highly porous magnetite nanocomposites (GN-HPMNs) have been prepared using a simple solvothermal method and used as an immobilization matrix for the fabrication of a solid-state electrochemiluminescence (ECL) sensor on paper-based chips. Highly porous Fe3O4 nanocrystal clusters were coated with acrylate and wrapped tightly on the skeleton of graphene nanosheets. The structures and sizes of the GN-HPMNs could be tuned by varying the proportions of the solvents ethylene glycol and diethylene glycol. Then, the relatively highly porous ones with an average diameter of about 65 nm were combined with Nafion to form composite films on an electrode surface for immobilization of Ru(bpy)3(2+) (bpy is 2,2'-bipyridine). Because of their porosity, negatively charged surface, and cooperative characteristics of magnetic nanomaterials and graphene, under an external magnetic field, the GN-HPMNs ensured effective immobilization, excellent electron transfer, and long-term stability of Ru(bpy)3(2+) in the composite film. The sensor developed exhibited excellent reproducibility with a relative standard deviation of 0.65% for 30 continuous cycles. It was found to be much more favorable for detecting compounds containing tertiary amino groups and DNAs with guanine and adenine. A detection limit (signal-to-noise ratio of 3) of 5.0 nM was obtained for tripropylamine. As an application example, 0.5 nM single-nucleotide mismatch could be detected. This was the first attempt to introduce magnetic nanomaterials and an external magnetic field into paper-based chips. The sensor developed has the advantages of high sensitivity, good stability, and wide potential applicability as well as simplicity, low cost, and good disposability. PMID:23132543

  7. Intra-articular injection of tranexamic acid via a drain plus drain-clamping to reduce blood loss in cementless total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Mutsuzaki Hirotaka

    2012-09-01

    Full Text Available Abstract Background Patients undergoing cementless total knee arthroplasty (TKA sometimes suffer large blood loss. In a retrospective study, we explored whether postoperative intra-articular retrograde injection of tranexamic acid (TA and leaving a drain clamp in place for 1 h reduced blood loss. Patients and methods Patients (n = 140 treated with unilateral primary cementless TKA (posterior cruciate ligament retained were divided into two groups: those who had an intra-articular injection of TA (1000 mg and drain clamping for 1 h postoperatively (study group, n = 70 and those who were not given TA and did not undergo clamping of their drains (control group, n = 70. Postoperative total blood loss, volume of drainage, hemoglobin level, transfusion amounts and rates, D-dimer level at postoperative day (POD 7, and complications were recorded. Results Total blood loss, total drainage, mean transfusion volume, and transfusion rates were lower in the study group than in controls (P P P  Conclusions Immediately postoperative intra-articular retrograde injection of TA and 1 h of drain-clamping effectively reduced blood loss and blood transfusion after cementless TKA. We believe that this method is simple, easy, and suitable for these patients.

  8. Titanium based flat heat pipes for computer chip cooling

    Science.gov (United States)

    Soni, Gaurav; Ding, Changsong; Sigurdson, Marin; Bozorgi, Payam; Piorek, Brian; MacDonald, Noel; Meinhart, Carl

    2008-11-01

    We are developing a highly conductive flat heat pipe (called Thermal Ground Plane or TGP) for cooling computer chips. Conventional heat pipes have circular cross sections and thus can't make good contact with chip surface. The flatness of our TGP will enable conformal contact with the chip surface and thus enhance cooling efficiency. Another limiting factor in conventional heat pipes is the capillary flow of the working fluid through a wick structure. In order to overcome this limitation we have created a highly porous wick structure on a flat titanium substrate by using micro fabrication technology. We first etch titanium to create very tall micro pillars with a diameter of 5 μm, a height of 40 μm and a pitch of 10 μm. We then grow a very fine nano structured titania (NST) hairs on all surfaces of the pillars by oxidation in H202. In this way we achieve a wick structure which utilizes multiple length scales to yield high performance wicking of water. It's capable of wicking water at an average velocity of 1 cm/s over a distance of several cm. A titanium cavity is laser-welded onto the wicking substrate and a small quantity of water is hermetically sealed inside the cavity to achieve a TGP. The thermal conductivity of our preliminary TGP was measured to be 350 W/m-K, but has the potential to be several orders of magnitude higher.

  9. Superplasticity in titanium alloys

    OpenAIRE

    J. Sieniawski; Motyka, M.

    2007-01-01

    Purpose: The paper reports characteristic of superplasticity phenomenon in titanium alloys and possibility of its applications.Design/methodology/approach: The main objective of the paper is to show features of superplastic forming of titanium alloys and current research trends aiming at widespread application of this technology.Findings: In the paper characteristic of selected superplastic titanium alloys was presented. The effect of microstructural parameters on superplasticity was consider...

  10. Porous Titanium for Dental Implant Applications

    Directory of Open Access Journals (Sweden)

    Zena J. Wally

    2015-10-01

    Full Text Available Recently, an increasing amount of research has focused on the biological and mechanical behavior of highly porous structures of metallic biomaterials, as implant materials for dental implants. Particularly, pure titanium and its alloys are typically used due to their outstanding mechanical and biological properties. However, these materials have high stiffness (Young’s modulus in comparison to that of the host bone, which necessitates careful implant design to ensure appropriate distribution of stresses to the adjoining bone, to avoid stress-shielding or overloading, both of which lead to bone resorption. Additionally, many coating and roughening techniques are used to improve cell and bone-bonding to the implant surface. To date, several studies have revealed that porous geometry may be a promising alternative to bulk structures for dental implant applications. This review aims to summarize the evidence in the literature for the importance of porosity in the integration of dental implants with bone tissue and the different fabrication methods currently being investigated. In particular, additive manufacturing shows promise as a technique to control pore size and shape for optimum biological properties.

  11. Classification of titanium dioxide

    International Nuclear Information System (INIS)

    In this work the X-ray diffraction (XRD), Scanning Electron Microscopy (Sem) and the X-ray Dispersive Energy Spectroscopy techniques are used with the purpose to achieve a complete identification of phases and mixture of phases of a crystalline material as titanium dioxide. The problem for solving consists of being able to distinguish a sample of titanium dioxide being different than a titanium dioxide pigment. A standard sample of titanium dioxide with NIST certificate is used, which indicates a purity of 99.74% for the TiO2. The following way is recommended to proceed: a)To make an analysis by means of X-ray diffraction technique to the sample of titanium dioxide pigment and on the standard of titanium dioxide waiting not find differences. b) To make a chemical analysis by the X-ray Dispersive Energy Spectroscopy via in a microscope, taking advantage of the high vacuum since it is oxygen which is analysed and if it is concluded that the aluminium oxide appears in a greater proportion to 1% it is established that is a titanium dioxide pigment, but if it is lesser then it will be only titanium dioxide. This type of analysis is an application of the nuclear techniques useful for the tariff classification of merchandise which is considered as of difficult recognition. (Author)

  12. Template-free synthesis of highly porous V2O5 cuboids with enhanced performance for lithium ion batteries.

    Science.gov (United States)

    Zhang, Cheng; Fang, Guozhao; Liang, Caiwu; Zhou, Jiang; Tan, Xiaoping; Pan, Anqiang; Liang, Shuquan

    2016-07-29

    Highly porous hierarchical V2O5 cuboids have been synthesized by a template-free PVP-assisted polyxol method and the formation mechanism is studied. The cuboids are assembled from numerous mesoporous nanoplates and the preferred orientation of each single nanoplate exposes the 〈110〉 facets, facilitating lithium-ion diffusion by offering a prior channel. This material exhibits a high capacity of 143 mA h g(-1), high rate capacity of 10 C and long life cycling performance up to 1000 cycles. The excellent electrochemical performance of V2O5 cuboid electrodes is due to its unique porous cuboid morphology and optimized structural stability upon cycling. This research provides an effective route to the construction of complex porous architectures assembled from nanocrystals through a surfactant-assisted synthesis method. PMID:27320105

  13. Template-free synthesis of highly porous V2O5 cuboids with enhanced performance for lithium ion batteries

    Science.gov (United States)

    Zhang, Cheng; Fang, Guozhao; Liang, Caiwu; Zhou, Jiang; Tan, Xiaoping; Pan, Anqiang; Liang, Shuquan

    2016-07-01

    Highly porous hierarchical V2O5 cuboids have been synthesized by a template-free PVP-assisted polyxol method and the formation mechanism is studied. The cuboids are assembled from numerous mesoporous nanoplates and the preferred orientation of each single nanoplate exposes the facets, facilitating lithium-ion diffusion by offering a prior channel. This material exhibits a high capacity of 143 mA h g‑1, high rate capacity of 10 C and long life cycling performance up to 1000 cycles. The excellent electrochemical performance of V2O5 cuboid electrodes is due to its unique porous cuboid morphology and optimized structural stability upon cycling. This research provides an effective route to the construction of complex porous architectures assembled from nanocrystals through a surfactant-assisted synthesis method.

  14. Experimental and Numerical Analyses of the Pull-out Response of a Steel Post/Bovine Bone Cementless Fixation

    Institute of Scientific and Technical Information of China (English)

    Khaled Gammoudi; Mohamed Kharrat; Maher Dammak

    2012-01-01

    Effect of initial interference fit on pull-out strength in cementless fixation between bovine tibia and smooth stainless steel post was investigated in this study.Compressive behavior of bovine spongious bone was studied using mechanical testing in order to evaluate the elastic-plastic properties in different regions of the proximal tibia.Friction tests were carried out in the aim to evaluate the friction behavior of the contact between bovine spongious bone and stainless steel.A cylindrical stainless steel post inserted in a pre-drilled bovine tibia with an initial interference fit was taken as an in vitro model to assess the contribution of post fixation to the initial stability of the Total Knee Arthroplasty (TKA) tibial component.Pull-out experiments were carried out for different initial interference fits.Finite Element Models (FEM) using local elastic-plastic properties of the bovine bone were developed for the analysis of the experimental ultimate pull-out force results.At the post/bone interface,Coulomb friction was considered in the FEM calculations with pressure-dependent friction coefficient.It was found that the FEM results of the ultimate force are in good agreement with the experimental results.The analysis of the FEM interfacial stresses indicates that the micro-slip initiation depends on the local bone properties.

  15. Correlative analysis of MRI-evident abductor hip muscle degeneration and power after minimally invasive versus conventional unilateral cementless THA.

    Science.gov (United States)

    Vasilakis, Ioannis; Solomou, Ekaterini; Vitsas, Vasilis; Fennema, Peter; Korovessis, Panagiotis; Siamblis, Dimitrios K

    2012-12-01

    The 2 main null hypotheses of this study were: (1) the 4-year surgical trauma-related degeneration within the hip abductor muscles after a minimally invasive approach to total hip arthroplasty would be similar to that following a conventional approach; and (2) no differences in perioperative blood loss or postoperative hip pain would be observed between the minimally invasive and conventional approaches.In 40 consecutive randomly selected adult patients with unilateral primary hip osteoarthritis, a cementless Zweymüller-Plus THA (Smith & Nephew Orthopaedics, Baar, Switzerland) was implanted by a single surgeon in 1 institution during the same period. Twenty patients underwent a minimally invasive approach (group A), and 20 patients underwent a conventional anterolateral approach (group B). Four years postoperatively, the operated and contralateral nonoperated hips of 37 available patients from both groups were examined with magnetic resonance imaging to show any changes in the gluteus medius and tensor fascia latae. Simultaneously, hip abductor power was measured bilaterally in both groups. Anthropometric data, blood loss, Short Form 36 self-assessment questionnaire, visual analog pain score, and walking distance were also analyzed.The reliability of magnetic resonance imaging and hip abductor power measurements was high. No difference was found in hip abductor power on the operated side between the 2 groups, whereas hip abductor power on the nonoperated side was significantly higher in both groups. This study revealed no mechanical and functional benefits in favor of patients undergoing minimally invasive vs conventional total hip arthroplasty.

  16. The effects of pulsed low frequency magnetic field in early rehabilitation of patients with cementless total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Đurović Aleksandar

    2006-01-01

    Full Text Available Introduction: Early rehabilitation of patients with cementless total hip arthroplasty (cTHA includes different physical modalities and pulsed low frequency magnetic field (PLFMF, which effects have not been explored yet. Objective: To investigate the effects of PLFMF which was applied in different doses in early rehabilitation of patients with cTHA. Method: Prospective, controlled, clinical study included 90 patients, divided in three groups with 30 patients each. First two groups were treated with high (group A or low (group B doses of PLFMF, in addition to kinesitherapy. Control group C was treated only with kinesitherapy. Study was completed in three weeks. Results: Subjects of group A had significantly lower pain than group B (p<0.01 and group C (p<0.001 subjects in the first postoperative week. Pain in group B subjects was significantly lower than in group C in all three postoperative weeks (p<0.01. In relation to other two groups, subjects of group A had higher hip Harris score values at the end of the third postoperative week (p<0.05, and they were faster on 10-meter distance at the end of the first postoperative week (p<0.01. Conclusion: PLFMF used in low and high doses for patients with cTHA had significant effects on pain abatement, especially at higher doses. Improvement of function was earlier and more manifested in the group treated with high doses of PLFMF.

  17. TITANIUM DAN PADUAN TITANIUM MATERIAL PILIHAN KEDOKTERAN GIGI MASA DEPAN

    OpenAIRE

    Bambang Irawan

    2015-01-01

    Nowadays, Titanium is used for dental implants, orthodontic wires an denture bases. In Indonesia they have been widely use especially for the orthodontic treatment. Survey conducted by students from University of Indonesia showed that users have little understanding in properties of Titanium. The article describes various matters on characteristic of Titanium. Titanium has low density, low elastic modulus, high tensile strength make attractive for use in dentistry. Titanium forms a very stabl...

  18. Effects of bio-functionalizing surface treatments on the mechanical behavior of open porous titanium biomaterials.

    Science.gov (United States)

    Amin Yavari, S; Ahmadi, S M; van der Stok, J; Wauthle, R; Riemslag, A C; Janssen, M; Schrooten, J; Weinans, H; Zadpoor, A A

    2014-08-01

    Bio-functionalizing surface treatments are often applied for improving the bioactivity of biomaterials that are based on otherwise bioinert titanium alloys. When applied on highly porous titanium alloy structures intended for orthopedic bone regeneration purposes, such surface treatments could significantly change the static and fatigue properties of these structures and, thus, affect the application of the biomaterial as bone substitute. Therefore, the interplay between biofunctionalizing surface treatments and mechanical behavior needs to be controlled. In this paper, we studied the effects of two bio-functionalizing surface treatments, namely alkali-acid heat treatment (AlAcH) and acid-alkali (AcAl), on the static and fatigue properties of three different highly porous titanium alloy implants manufactured using selective laser melting. It was found that AlAcH treatment results in minimal mass loss. The static and fatigue properties of AlAcH specimens were therefore not much different from as-manufactured (AsM) specimens. In contrast, AcAl resulted in substantial mass loss and also in significantly less static and fatigue properties particularly for porous structures with the highest porosity. The ratio of the static mechanical properties of AcAl specimens to that of AsM specimen was in the range of 1.5-6. The fatigue lives of AcAl specimens were much more severely affected by the applied surface treatments with fatigue lives up to 23 times smaller than that of AsM specimens particularly for the porous structures with the highest porosity. In conclusion, the fatigue properties of surface treated porous titanium are dependent not only on the type of applied surface treatment but also on the porosity of the biomaterial.

  19. Two-stage revision surgery with preformed spacers and cementless implants for septic hip arthritis: a prospective, non-randomized cohort study

    Directory of Open Access Journals (Sweden)

    Logoluso Nicola

    2011-05-01

    Full Text Available Abstract Background Outcome data on two-stage revision surgery for deep infection after septic hip arthritis are limited and inconsistent. This study presents the medium-term results of a new, standardized two-stage arthroplasty with preformed hip spacers and cementless implants in a consecutive series of adult patients with septic arthritis of the hip treated according to a same protocol. Methods Nineteen patients (20 hips were enrolled in this prospective, non-randomized cohort study between 2000 and 2008. The first stage comprised femoral head resection, debridement, and insertion of a preformed, commercially available, antibiotic-loaded cement hip spacer. After eradication of infection, a cementless total hip arthroplasty was implanted in the second stage. Patients were assessed for infection recurrence, pain (visual analog scale [VAS] and hip joint function (Harris Hip score. Results The mean time between first diagnosis of infection and revision surgery was 5.8 ± 9.0 months; the average duration of follow up was 56.6 (range, 24 - 104 months; all 20 hips were successfully converted to prosthesis an average 22 ± 5.1 weeks after spacer implantation. Reinfection after total hip joint replacement occurred in 1 patient. The mean VAS pain score improved from 48 (range, 35 - 84 pre-operatively to 18 (range, 0 - 38 prior to spacer removal and to 8 (range, 0 - 15 at the last follow-up assessment after prosthesis implantation. The average Harris Hip score improved from 27.5 before surgery to 61.8 between the two stages to 92.3 at the final follow-up assessment. Conclusions Satisfactory outcomes can be obtained with two-stage revision hip arthroplasty using preformed spacers and cementless implants for prosthetic hip joint infections of various etiologies.

  20. Machining of titanium alloys

    CERN Document Server

    2014-01-01

    This book presents a collection of examples illustrating the resent research advances in the machining of titanium alloys. These materials have excellent strength and fracture toughness as well as low density and good corrosion resistance; however, machinability is still poor due to their low thermal conductivity and high chemical reactivity with cutting tool materials. This book presents solutions to enhance machinability in titanium-based alloys and serves as a useful reference to professionals and researchers in aerospace, automotive and biomedical fields.

  1. Titanium allergy: A literature review

    Directory of Open Access Journals (Sweden)

    Manish Goutam

    2014-01-01

    Full Text Available Titanium has gained immense popularity and has successfully established itself as the material of choice for dental implants. In both medical and dental fields, titanium and its alloys have demonstrated success as biomedical devices. Owing to its high resistance to corrosion in a physiological environment and the excellent biocompatibility that gives it a passive, stable oxide film, titanium is considered the material of choice for intraosseous use. There are certain studies which show titanium as an allergen but the resources to diagnose titanium sensivity are very limited. Attention is needed towards the development of new and precise method for early diagnosis of titanium allergy and also to find out the alternative biomaterial which can be used in place of titanium. A review of available articles from the Medline and PubMed database was done to find literature available regarding titanium allergy, its diagnosis and new alternative material for titanium.

  2. Facile synthesis of a mechanically robust and highly porous NiO film with excellent electrocatalytic activity towards methanol oxidation

    Science.gov (United States)

    Wang, Luoyuan; Zhang, Guoge; Liu, Yan; Li, Wenfang; Lu, Wei; Huang, Haitao

    2016-05-01

    Considerable research is being conducted in searching for effective anode catalysts in alkaline direct methanol fuel cells (DMFCs). Although significant progress has been achieved, it is still challenging to prepare non-Pt catalysts with both excellent activity and good durability. Herein, a highly porous NiO film is developed by a facile and fast anodization approach. The anodic NiO film demonstrates a high surface area, large mesopore volume and small crystallite size, leading to facilitated adsorption of reaction species, easy electrolyte penetration and fast reaction kinetics. Furthermore, as anodic NiO is grown in situ on a metallic substrate with strong adhesion strength and good electrical contact, it can be used directly as an anode catalyst for methanol oxidation without the need to add any binder or conducting agent. Such an additive-free approach greatly expedites the catalyst preparation process. The anodic NiO shows lower methanol oxidation potential, higher oxidation current and better catalytic durability than most of the state-of-the-art Ni-based catalysts reported elsewhere. As anodization is a simple, low cost and easily scaled up method, the work described here provides an exciting direction to speed up the practical application of alkaline DMFCs.Considerable research is being conducted in searching for effective anode catalysts in alkaline direct methanol fuel cells (DMFCs). Although significant progress has been achieved, it is still challenging to prepare non-Pt catalysts with both excellent activity and good durability. Herein, a highly porous NiO film is developed by a facile and fast anodization approach. The anodic NiO film demonstrates a high surface area, large mesopore volume and small crystallite size, leading to facilitated adsorption of reaction species, easy electrolyte penetration and fast reaction kinetics. Furthermore, as anodic NiO is grown in situ on a metallic substrate with strong adhesion strength and good electrical contact

  3. Functional and radiographic evaluation and quality of life analysis after cementless total hip arthroplasty with ceramic bearings: minimum of 5 years follow-up

    Directory of Open Access Journals (Sweden)

    Rafael Borghi Mortat

    2013-12-01

    Full Text Available Objective: The aim of the study is to analyze and correlate functional and radiographic results and quality of life in patients undergoing cementless total hip arthroplasty with ceramic surface, performed at Hospital Servidor Publico de Sao Paulo from 2001 to 2006. Methods: We retrospectively analyzed 35 hips treated with cementless total hip arthroplasty with ceramic surfaces with a minimum follow-up of 5 years. Functional evaluation was based on the Harris Hip Score (HHS. Radiographic evaluation was based on the method proposed by Charles Engh for evaluation of femoral osseointegration and on DeLee and Charnley zones for acetabulum. Quality of life was assessed by SF-36 questionnaire. Results: The HHS presented excellent and good results in 91% of patients postoperatively (mean of 93.14 points HHS. As for radiographic evaluation, we found excellent results in 100% of evaluated hips (proven osseointegration. SF-36 scores were not compared to the control group for the following components: pain, vitality, mental health and social aspects. The difference between HHS pre and postoperatively had a statistically significant correlation with physical functioning of the SF-36. Conclusion: Total hip arthroplasty with ceramic surface is a treatment that enables functional improvement of the hip and increases quality of life of patients to levels close to those of people without joint diseases.

  4. Five-year results of a cementless short-hip-stem prosthesis

    Directory of Open Access Journals (Sweden)

    Ralf H. Wittenberg

    2013-03-01

    Full Text Available Hip prosthesis stems with a short stem length and proximal fixation geometry support a bone-preserving and muscle-sparing implantation and should also allow for revision surgery with a standard hip stem. We present 250 prospectively documented clinical and radiological results from the Metha Short Hip Stem prosthesis (B. Braun-Aesculap, Tuttlingen, Germany after an average follow-up of 4.9 years. The average patient age at surgery was 60 years. Indication for total hip replacement was primary osteoarthrosis (OA (78% of patients, OA based on developmental dyspla- sia of the hip (16%, and other indications (6%. At the last follow-up, the average Harris Hip Score was 97 points. 85% of patients were very satisfied and 14% were satisfied after surgery, whereas 1% were dissatisfied. Pain according to the Visual Analogue Scale improved from 7.4 (min 1.6, max 9.5 pre-operatively to 0.23 (min 0, max 6.6. No joint dislocations occurred when predominantly using 28 mm and 32 mm prosthesis heads. Nine short-stems were revised: three after bacterial infections, two after primary via valsa with penetration of the femoral cortex two and three months after surgery, and three after early aseptic cases of loosening within the first year. A further nine osseously consolidated short-stems had to be replaced due to breakage of the modular titanium cone adapter after an average of 3.1 years (min 1.9, max 4.4. All surgical revisions were performed using primary standard stems. Without taking the material-related adapter failures into account, a five year Kaplan-Meier survival rate of 96.7% (95% confidence interval 93.4-98.3 was determined for the short-stem prostheses. There were no radiological signs of loosening in any of the short-stem prostheses at the last examination. Fine sclerotic lines were detected in Gruen’s AP zones 1 (19% and 2 (10.5%, individual hypertrophies in zone 3 (3.5%, fine seams in zones 4 (5.5% and 5 (4%, without pedestal formations in zone 4

  5. Preparation of highly porous binderless activated carbon electrodes from fibres of oil palm empty fruit bunches for application in supercapacitors.

    Science.gov (United States)

    Farma, R; Deraman, M; Awitdrus, A; Talib, I A; Taer, E; Basri, N H; Manjunatha, J G; Ishak, M M; Dollah, B N M; Hashmi, S A

    2013-03-01

    Fibres from oil palm empty fruit bunches, generated in large quantities by palm oil mills, were processed into self-adhesive carbon grains (SACG). Untreated and KOH-treated SACG were converted without binder into green monolith prior to N2-carbonisation and CO2-activation to produce highly porous binderless carbon monolith electrodes for supercapacitor applications. Characterisation of the pore structure of the electrodes revealed a significant advantage from combining the chemical and physical activation processes. The electrochemical measurements of the supercapacitor cells fabricated using these electrodes, using cyclic voltammetry, electrochemical impedance spectroscopy and galvanostatic charge-discharge techniques consistently found that approximately 3h of activation time, achieved via a multi-step heating profile, produced electrodes with a high surface area of 1704m(2)g(-1) and a total pore volume of 0.889cm(3)g(-1), corresponding to high values for the specific capacitance, specific energy and specific power of 150Fg(-1), 4.297Whkg(-1) and 173Wkg(-1), respectively.

  6. Fabrication of highly porous scaffold materials based on functionalized oligolactides and preliminary results on their use in bone tissue engineering

    Directory of Open Access Journals (Sweden)

    Vogt S.

    2002-12-01

    Full Text Available Tissue engineering offers a promising new approach to repair bone defects. Its practical realisation is connected with the development of suitable scaffold materials. In the present work, functionalized oligolactides have been prepared and used as macromers for the scaffold fabrication The developed fabrication process leads to highly porous scaffolds, available in various shapes and sizes, with an open inter-connective pore structure and porosities up to 90 %. Degradable or even osteoconductive components as well as biocompatible co-monomers can be used as additives to modulate the scaffold properties. Under in vitro conditions, the scaffolds exhibit a continuous degradation with varying degradation rates depending on their material composition. In vitro studies on the cultivation of osteoblasts on the scaffolds were performed and revealed their excellent biocompatibility. Cell growth on the scaffold surfaces and inside the scaffolds, formation of extracellular matrix and starting mineralization were detected by microscopical and histological analyses. Based on these results the developed materials are well-suited candidates for the design of tailor-made matrices in bone tissue engineering

  7. Synthesis of Highly Porous Poly(tert-butyl acrylate)-b-polysulfone-b-poly(tert-butyl acrylate) Asymmetric Membranes

    KAUST Repository

    Xie, Yihui

    2016-03-24

    For the first time, self-assembly and non-solvent induced phase separation was applied to polysulfone-based linear block copolymers, reaching mechanical stability much higher than other block copolymers membranes used in this method, which were mainly based on polystyrene blocks. Poly(tert-butyl acrylate)-b-polysulfone-b-poly(tert-butyl acrylate) (PtBA30k-b-PSU14k-b-PtBA30k) with a low polydispersity of 1.4 was synthesized by combining step-growth condensation and RAFT polymerization. Various advanced electron microscopies revealed that PtBA30k-b-PSU14k-b-PtBA30k assembles into worm-like cylindrical micelles in DMAc and adopts a “flower-like” arrangement with the PSU central block forming the shell. Computational modeling described the mechanism of micelle formation and morphological transition. Asymmetric nanostructured membranes were obtained with a highly porous interconnected skin layer and a sublayer with finger-like macrovoids. Ultrafiltration tests confirmed a water permeance of 555 L m-2 h-1 bar-1 with molecular weight cut-off of 28 kg/mol. PtBA segments on the membrane surface were then hydrolyzed and complexed with metals, leading to cross-linking and enhancement of antibacterial capability.

  8. Rapid synthesis of monodispersed highly porous spinel nickel cobaltite (NiCo2O4) electrode material for supercapacitors

    International Nuclear Information System (INIS)

    Monodispersed highly porous spinel nickel cobaltite electrode material was successfully synthesized in a short time using combustion technique. Single phase cubic nature of the spinel nickel cobaltite with average crystallite size of 24 nm was determined from X-ray diffraction study. Functional groups present in the compound were determined from FTIR study and it further confirms the spinel formation. FESEM images reveal the porous nature of the prepared material and uniform size distribution of the particles. Electrochemical evaluation was performed using Cyclic Voltammetry (CV) technique, Chronopotentiometry (CP) and Electrochemical Impedance Spectroscopy (EIS). Results reveal the typical pseudocapacitive behaviour of the material. Maximum capacitance of 754 F/g was calculated at the scan rate of 5 mV/s, high capacitance was due to the unique porous morphology of the electrode. Nyquist plot depicts the low resistance and good electrical conductivity of nickel cobaltite. It has been found that nickel cobaltite prepared by this typical method will be a potential electrode material for supercapcitor application

  9. Carbon/PEEK composite materials as an alternative for stainless steel/titanium hip prosthesis: a finite element study.

    Science.gov (United States)

    Rezaei, Farshid; Hassani, Kamran; Solhjoei, Nosratollah; Karimi, Alireza

    2015-12-01

    Total hip replacement (THR) has been ranked within the most typical surgical processes in the world. The durability of the prosthesis and loosening of prosthesis are the main concerns that mostly reported after THR surgeries. In THR, the femoral prosthesis can be fixed by either cement or cementless methods in the patient's bones. In both procedures, the stability of the prosthesis in the hosted bone has a key asset in its long-term durability and performance. This study aimed to execute a comparative finite element simulation to assess the load transfer between the prosthesis, which is made of carbon/PEEK composite and stainless steel/titanium, and the femur bone. The mechanical behavior of the cortical bone was assumed as a linear transverse isotropic while the spongy bone was modeled like a linear isotropic material. The implants were made of stainless steel (316L) and titanium alloy as they are common materials for implants. The results showed that the carbon/PEEK composites provide a flatter load transfer from the upper body to the leg compared to the stainless steel/titanium prosthesis. Furthermore, the results showed that the von Mises stress, principal stress, and the strain in the carbon/PEEK composites prosthesis were significantly lower than that made of the stainless steel/titanium. The results also imply that the carbon/PEEK composites can be applied to introduce a new optimum design for femoral prosthesis with adjustable stiffness, which can decrease the stress shielding and interface stress. These findings will help clinicians and biomedical experts to increase their knowledge about the hip replacement.

  10. LASER GAS NITRIDING OF TITANIUM AND TITANIUM ALLOYS

    OpenAIRE

    J. J. DAI; Hou, S. Q.

    2009-01-01

    Titanium and titanium alloys are widely used in many fields due to some of their characteristics such as light density, high strength, and excellent corrosion resistance. However, poor mechanical performances limit their practical applications. Laser gas nitriding is a promising method used to improve the surface properties of components. Recent developments on laser gas nitriding of titanium and titanium alloys are reviewed. The processing parameters have important effects on the resulting c...

  11. Productive Machining of Titanium Alloys

    OpenAIRE

    Čejka, Libor

    2013-01-01

    This diploma thesis is focused on a productive machining of titanium alloys. At the beginning it deals about titanium and its alloys. It describes chip generation mechanism, tool blunting and surface quality. Further it contains modern strategies of efficient titanium alloys machining. Then it analyzes contemporary manufacturing technology of hinge made of titanium alloy Ti-6Al-4V in Frentech Aerospace s.r.o. company, and at the end finds possibility of savings by inovation of roughing process.

  12. High-temperature Titanium Alloys

    OpenAIRE

    A.K. Gogia

    2005-01-01

    The development of high-temperature titanium alloys has contributed significantly to the spectacular progress in thrust-to-weight ratio of the aero gas turbines. This paper presents anoverview on the development of high-temperature titanium alloys used in aero engines and potential futuristic materials based on titanium aluminides and composites. The role of alloychemistry, processing, and microstructure, in determining the mechanical properties of titanium alloys is discussed. While phase eq...

  13. Titanium metal: extraction to application

    Energy Technology Data Exchange (ETDEWEB)

    Gambogi, Joseph (USGS, Reston, VA); Gerdemann, Stephen J.

    2002-09-01

    In 1998, approximately 57,000 tons of titanium metal was consumed in the form of mill products (1). Only about 5% of the 4 million tons of titanium minerals consumed each year is used to produce titanium metal, with the remainder primarily used to produce titanium dioxide pigment. Titanium metal production is primarily based on the direct chlorination of rutile to produce titanium tetrachloride, which is then reduced to metal using the Kroll magnesium reduction process. The use of titanium is tied to its high strength-to-weight ratio and corrosion resistance. Aerospace is the largest application for titanium. In this paper, we discuss all aspects of the titanium industry from ore deposits through extraction to present and future applications. The methods of both primary (mining of ore, extraction, and purification) and secondary (forming and machining) operations will be analyzed. The chemical and physical properties of titanium metal will be briefly examined. Present and future applications for titanium will be discussed. Finally, the economics of titanium metal production also are analyzed as well as the advantages and disadvantages of various alternative extraction methods.

  14. Industrial experience with titanium

    International Nuclear Information System (INIS)

    Titanium is a reference material for the construction of waste containers in the Canadian Nuclear Fuel Waste Management Program. It has been in industrial service for over 30 a, often in severe corrosion environments, but it is still considered a relatively exotic material with limited operating history. This has arisen because of the aerospace applications of this material and the misconception that the high strength-to-weight ratio dominates the choice of this material. In fact, the advantage of titanium lies in its high reliability and excellent corrosion resistance. It has a proven record in seawater heat exchanger service and a demonstrated excellent reliability even in polluted water. For many reasons it is the technically correct choice of material for marine applications. In this report we review the industrial service history of titanium, particularly in hot saline environments, and demonstrate that it is a viable waste container material, based upon this industrial service history and operating experience. (author)

  15. Surface modification of titanium and titanium alloys by ion implantation.

    Science.gov (United States)

    Rautray, Tapash R; Narayanan, R; Kwon, Tae-Yub; Kim, Kyo-Han

    2010-05-01

    Titanium and titanium alloys are widely used in biomedical devices and components, especially as hard tissue replacements as well as in cardiac and cardiovascular applications, because of their desirable properties, such as relatively low modulus, good fatigue strength, formability, machinability, corrosion resistance, and biocompatibility. However, titanium and its alloys cannot meet all of the clinical requirements. Therefore, to improve the biological, chemical, and mechanical properties, surface modification is often performed. In view of this, the current review casts new light on surface modification of titanium and titanium alloys by ion beam implantation.

  16. Tensile and creep properties of titanium-vanadium, titanium-molybdenum, and titanium-niobium alloys

    Science.gov (United States)

    Gray, H. R.

    1975-01-01

    Tensile and creep properties of experimental beta-titanium alloys were determined. Titanium-vanadium alloys had substantially greater tensile and creep strength than the titanium-niobium and titanium-molybdenum alloys tested. Specific tensile strengths of several titanium-vanadium-aluminum-silicon alloys were equivalent or superior to those of commercial titanium alloys to temperatures of 650 C. The Ti-50V-3Al-1Si alloy had the best balance of tensile strength, creep strength, and metallurgical stability. Its 500 C creep strength was far superior to that of a widely used commercial titanium alloy, Ti-6Al-4V, and almost equivalent to that of newly developed commercial titanium alloys.

  17. Diesel spray interaction with highly porous structures for supporting of liquid distribution in space and its vaporization

    Science.gov (United States)

    Weclas, M.; Cypris, J.; Maksoud, T. M. A.

    2012-05-01

    If a free high velocity jet (Diesel spray) propagating in space outwards of the nozzle exit collides (impinges onto) with highly porous structure (PM) the results of such an interaction is characterized by significant radial spreading of the spray, reduced axial penetration length, significantly increase spray surface area, reduced propagating velocity after interaction with PM and enhanced vaporization if the porous structure is hot. Due to those effects a very quick spray distribution in space is observed. This effect can, for example, be used for mixture homogenization for a clean combustion process. The rapid radial spreading of the spray by interaction with a porous structure is a result of multi-jet splitting. To some extent, Diesel jet interaction with a three-dimensional porous structure could be simulated by jet interaction with small cylindrical obstacles simulating wall junctions of a real porous medium. Based on the principles of spray interaction with porous structure there are two different cases to be considered: 1-porous medium in the form of thin ring positioned around the fuel nozzle (called distribution nozzle); 2-porous medium in the form of three-dimensional volumetric reactor. In the case of the distribution nozzle the target is to distribute fuel in space outside the porous ring and to enhance the vaporization process. In the case of combustion reactor the spray interacts with a number of wall junctions inside the porous structure and the main target is to homogeneously distribute the spray in PM volume, to evaporate the fuel and to mix with combustion air. The jets leaving diesel nozzle very early interact with porous ring resulting in a shining-like fuel distribution in space: for a cold ring a multi-jet splitting is responsible for observed fuel distribution in space; for a hot porous ring a superposition of fuel distribution and fuel vaporization must be considered.

  18. Comparison of polymethylmethacrylate (PMMA, native calcium sulfate, and high porous calcium sulfate beads as gentamicin carriers and osteoblast attachment

    Directory of Open Access Journals (Sweden)

    Chaiyakorn Thitiyanaporn

    2013-06-01

    Full Text Available Calcium sulfate, a bioresorbable material, has been used as a bone substitute material and antibiotic vehicle. The increasing porosity of calcium sulfate beads might improve drug delivery capacity as well as enhance the antibiotic elution property. High porous calcium sulfate (HPCS beads were fabricated using a salt leaching technique as a new bead type for antibiotic delivery system. Gentamicin-based antibiotic beads were conducted by impregnating gentamicin (3.8% w/w with polymethylmethacrylate (PMMA, or coating of PMMA, native calcium sulfate (NCS, and HPCS with gentamicin solution. Physical properties, microstructure, and gentamicin elution from gentamicin-impregnated PMMA (GI-PMMA, gentamicincoated PMMA (G-PMMA, gentamicin-coated NCS (G-NCS, and gentamicin-coated HPCS (G-HPCS were compared. The osteoblast attachment revealed that PMMA, NCS, and HPCS beads were not toxic to h-OBs after co-incubation for sevendays. Furthermore, more h-OBs attachment appeared in HPCS beads compared to PMMA and NCS beads after co-culture for 7 days. Eluted gentamicin from G-NCS and G-HPCS beads were greater than those from GI-PMMA and G-PMMA beads during the experimental period. All types of beads were able to elute gentamicin for 10 days except G-PMMA, which released gentamicin only for four days. The highest to lowest total concentrations of eluted gentamicin were from G-NCS, G-HPCS,G-PMMA, and GI-PMMA, respectively. These results suggested that the HPCS beads improved local antibiotic delivery and improved h-OBs attachment.

  19. Mandibular reconstruction with a bioactive-coated cementless Ti6Al4V modular endoprosthesis in Macaca fascicularis

    NARCIS (Netherlands)

    Chanchareonsook, N.; Tideman, H.; Lee, S.; Hollister, S.J.; Flanagan, C.; Jansen, J.A.

    2014-01-01

    The titanium mandibular modular endoprosthesis fixed with polymethylmethacrylate cement in the medullary space of the mandible has been introduced in previous studies. However, the internal parts of these devices have been found to be prone to loosening and wound dehiscence. The current study introd

  20. Machining of Titanium Alloys

    OpenAIRE

    Karásek, Jan

    2008-01-01

    The main goal of this work is the analysis of manufacturing costs for the component of wheel´s blower. Followed by setting up the size of specific cutting force for milling operation of the titanium alloy Ti-Al6-Mo2-Cr2-Fe-Si, the used tool was a milling cutter which is made out of sintered carbide with conical and spherical face. The final values which are at intervals of 1500 to 1800 MPa were compared with the values of the Sandvik Coromant firm kc = 1690 MPa, for titanium alloy with the st...

  1. Titanium alkoxide compound

    Science.gov (United States)

    Boyle, Timothy J.

    2007-08-14

    A titanium alkoxide composition is provided, as represented by the chemical formula (OC.sub.6H.sub.5N).sub.2Ti(OC.sub.6H.sub.5NH.sub.2).sub.2. As prepared, the compound is a crystalline substance with a hexavalent titanium atom bonded to two OC.sub.6H.sub.5NH.sub.2 groups and two OC.sub.6H.sub.5N groups with a theoretical molecular weight of 480.38, comprising 60.01% C, 5.04% H and 11.66% N.

  2. Chondrogenesis of human bone marrow mesenchymal stromal cells in highly porous alginate-foams supplemented with chondroitin sulfate

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Zhao [Department of Orthopaedic, Trauma and Reconstructive Surgery, Charité-Universitätsmedizin-Berlin Campus Benjamin Franklin, Berlin (Germany); Nooeaid, Patcharakamon [Institute of Biomaterials, Department of Materials Science and Engineering, University of Erlangen-Nuremberg (Germany); Kohl, Benjamin [Department of Orthopaedic, Trauma and Reconstructive Surgery, Charité-Universitätsmedizin-Berlin Campus Benjamin Franklin, Berlin (Germany); Roether, Judith A.; Schubert, Dirk W. [Institute of Polymer Materials, Department of Materials Science and Engineering, University of Erlangen-Nuremberg (Germany); Meier, Carola [Department of Orthopaedic, Trauma and Reconstructive Surgery, Charité-Universitätsmedizin-Berlin Campus Benjamin Franklin, Berlin (Germany); Boccaccini, Aldo R. [Institute of Biomaterials, Department of Materials Science and Engineering, University of Erlangen-Nuremberg (Germany); Godkin, Owen; Ertel, Wolfgang; Arens, Stephan [Department of Orthopaedic, Trauma and Reconstructive Surgery, Charité-Universitätsmedizin-Berlin Campus Benjamin Franklin, Berlin (Germany); Schulze-Tanzil, Gundula, E-mail: gundula.schulze@pmu.ac.at [Department of Orthopaedic, Trauma and Reconstructive Surgery, Charité-Universitätsmedizin-Berlin Campus Benjamin Franklin, Berlin (Germany); Institute of Anatomy, Paracelsus Medical University, Nuremberg (Germany)

    2015-05-01

    To overcome the limited intrinsic cartilage repair, autologous chondrocyte or bone-marrow-derived mesenchymal stromal cell (BM-MSC) was implanted into cartilage defects. For this purpose suitable biocompatible scaffolds are needed to provide cell retention, chondrogenesis and initial mechanical stability. The present study should indicate whether a recently developed highly porous alginate (Alg) foam scaffold supplemented with chondroitin sulfate (CS) allows the attachment, survival and chondrogenesis of BM-MSCs and articular chondrocytes. The foams were prepared using a freeze-drying method; some of them were supplemented with CS and subsequently characterized for porosity, biodegradation and mechanical profile. BM-MSCs were cultured for 1–2 weeks on the scaffold either under chondrogenic or maintenance conditions. Cell vitality assays, histology, glycosaminoglycan (sGAG) assay, and type II and I collagen immunolabelings were performed to monitor cell growth and extracellular matrix (ECM) synthesis in the scaffolds. Scaffolds had a high porosity ~ 93–95% with a mean pore sizes of 237 ± 48 μm (Alg) and 197 ± 61 μm (Alg/CS). Incorporation of CS increased mechanical strength of the foams providing gradually CS release over 7 days. Most of the cells survived in the scaffolds. BM-MSCs and articular chondrocytes formed rounded clusters within the scaffold pores. The BM-MSCs, irrespective of whether cultured under non/chondrogenic conditions and chondrocytes produced an ECM containing sGAGs, and types II and I collagen. Total collagen and sGAG contents were higher in differentiated BM-MSC cultures supplemented with CS than in CS-free foams after 14 days. The cell cluster formation induced by the scaffolds might stimulate chondrogenesis via initial intense cell–cell contacts. - Highlights: • Alginate foam scaffolds revealed a high porosity and mean pore size of 197–237 μm. • Chondroitin sulfate was released over 14 days by the scaffolds. • Chondrocytes

  3. The effect of abductor muscle and anterior-posterior hip contact load simulation on the in-vitro primary stability of a cementless hip stem

    Directory of Open Access Journals (Sweden)

    Frei Hanspeter

    2010-06-01

    Full Text Available Abstract Background In-vitro mechanical tests are commonly performed to assess pre-clinically the effect of implant design on the stability of hip endoprostheses. There is no standard protocol for these tests, and the forces applied vary between studies. This study examines the effect of the abductor force with and without application of the anterior-posterior hip contact force in the in-vitro assessment of cementless hip implant stability. Methods Cementless stems (VerSys Fiber Metal were implanted in twelve composite femurs which were divided into two groups: group 1 (N = 6 was loaded with the hip contact force only, whereas group 2 (N = 6 was additionally subjected to an abductor force. Both groups were subjected to the same cranial-caudal hip contact force component, 2.3 times body weight (BW and each specimen was subjected to three levels of anterior-posterior hip contact load: 0, -0.1 to 0.3 BW (walking, and -0.1 to 0.6 BW (stair climbing. The implant migration and micromotion relative to the femur was measured using a custom-built system comprised of 6 LVDT sensors. Results Substantially higher implant motion was observed when the anterior-posterior force was 0.6BW compared to the lower anterior-posterior load levels, particularly distally and in retroversion. The abductor load had little effect on implant motion when simulating walking, but resulted in significantly less motion than the hip contact force alone when simulating stair climbing. Conclusions The anterior-posterior component of the hip contact load has a significant effect on the axial motion of the stem relative to the bone. Inclusion of the abductor force had a stabilizing effect on the implant motion when simulating stair climbing.

  4. High-temperature Titanium Alloys

    Directory of Open Access Journals (Sweden)

    A.K. Gogia

    2005-04-01

    Full Text Available The development of high-temperature titanium alloys has contributed significantly to the spectacular progress in thrust-to-weight ratio of the aero gas turbines. This paper presents anoverview on the development of high-temperature titanium alloys used in aero engines and potential futuristic materials based on titanium aluminides and composites. The role of alloychemistry, processing, and microstructure, in determining the mechanical properties of titanium alloys is discussed. While phase equilibria and microstructural stability consideration haverestricted the use of conventional titanium alloys up to about 600 "C, alloys based on TiPl (or,, E,AINb (0, TiAl (y, and titaniumltitanium aluminides-based composites offer a possibility ofquantum jump in the temperature capability of titanium alloys.

  5. Casting and Mechanized Titanium Restorations

    OpenAIRE

    Madrigal, A.; Lopez, I; Suarez, MJ; Salido, MP.

    2002-01-01

    INTRODUCTION: New materials and methods for clinical dentistry are continuously being introduced. There is a growing interest in the use of titanium as a restorative material for several reasons: its relatively low cost, favorable physical properties and biocompatibility. However, titanium is technically more difficult to handle than conventional metal alloys. There are two fabrication methods for titanium restorations: casting and mechanized (a combination of machine duplication and spark er...

  6. Titanium: light, strong, and white

    Science.gov (United States)

    Woodruff, Laurel; Bedinger, George

    2013-01-01

    Titanium (Ti) is a strong silver-gray metal that is highly resistant to corrosion and is chemically inert. It is as strong as steel but 45 percent lighter, and it is twice as strong as aluminum but only 60 percent heavier. Titanium dioxide (TiO2) has a very high refractive index, which means that it has high light-scattering ability. As a result, TiO2 imparts whiteness, opacity, and brightness to many products. ...Because of the unique physical properties of titanium metal and the whiteness provided by TiO2, titanium is now used widely in modern industrial societies.

  7. Highly porous Zinc Stannate (Zn2SnO4) nanofibers scaffold photoelectrodes for efficient methyl ammonium halide perovskite solar cells

    OpenAIRE

    Mali, Sawanta S.; Chang Su Shim; Chang Kook Hong

    2015-01-01

    Development of ternary metal oxide (TMO) based electron transporting layer (ETL) for perovskite solar cell open a new approaches toward efficient a unique strategy for solid state dye-sensitized solar cells (ssDSSCs). In the present investigation, highly porous zinc tin oxide (Zn2SnO4) scaffold nanofibers has been synthesized by electrospinning technique and successfully used for methyl ammonium lead halide (CH3NH3PbI3) perovskite sensitized solid state solar cells. The fabricated optimized p...

  8. Chemical changes of titanium and titanium dioxide under electron bombardment

    Directory of Open Access Journals (Sweden)

    Romins Brasca

    2007-09-01

    Full Text Available The electron induced effect on the first stages of the titanium (Ti0 oxidation and titanium dioxide (Ti4+ chemical reduction processes has been studied by means of Auger electron spectroscopy. Using factor analysis we found that both processes are characterized by the appearance of an intermediate Ti oxidation state, Ti2O3 (Ti3+.

  9. Chemical changes of titanium and titanium dioxide under electron bombardment

    OpenAIRE

    Romins Brasca; Luciana Ines Vergara; Mario César Guillermo Passeggi; Julio Ferrón

    2007-01-01

    The electron induced effect on the first stages of the titanium (Ti0) oxidation and titanium dioxide (Ti4+) chemical reduction processes has been studied by means of Auger electron spectroscopy. Using factor analysis we found that both processes are characterized by the appearance of an intermediate Ti oxidation state, Ti2O3 (Ti3+).

  10. Highly porous open cell Ti-foam using NaCl as temporary space holder through powder metallurgy route

    International Nuclear Information System (INIS)

    Highlights: ► NaCl crystals has been used as space holder. ► Variation of NaCl:Ti ratio varies porosity (65–80%). ► NaCl is cubic but the cells are spherical. ► Two types of pores: micro and macro pores are obtained. ► Foams are suitable for bones scaffolds and engineering applications. - Abstract: Open cell Titanium-foam (Ti-foam) with varying porosities (65–80%) was prepared using sodium chloride (NaCl) particles as space holder through powder metallurgy route. In order to ensure sufficient handling strength in cold compacted pallets, 2 wt.% polyvinyl alcohol (PVA) solutions (5 wt.% PVA in water) was mixed with the mixture of Ti and NaCl powders prior to cold compaction. After sintering, NaCl salt was removed by dissolving it in hot water. Detailed Energy dispersive X-ray (EDX) analysis and X-ray diffraction studies of the prepared Ti-foams were conducted to examine any physical and chemical changes in the phase constituents. The micro-architectural characteristics, density vis-a-vis porosity, and compressive deformation behavior of the synthesized foams were evaluated to examine their suitability as biomaterial and engineering applications

  11. Titanium dioxide nanotube films

    Energy Technology Data Exchange (ETDEWEB)

    Roman, Ioan, E-mail: roman@metav-cd.ro [S.C. METAV-Research and Development S.R.L., Bucharest, 31C. A. Rosetti, 020011 (Romania); Trusca, Roxana Doina; Soare, Maria-Laura [S.C. METAV-Research and Development S.R.L., Bucharest, 31C. A. Rosetti, 020011 (Romania); Fratila, Corneliu [Research and Development National Institute for Nonferrous and Rare Metals, Pantelimon, 102 Biruintei, 077145 (Romania); Krasicka-Cydzik, Elzbieta [University of Zielona Gora, Department of Biomedical Engineering Division, 9 Licealna, 65-417 (Poland); Stan, Miruna-Silvia; Dinischiotu, Anca [University of Bucharest, Department of Biochemistry and Molecular Biology, 36-46 Mihail Kogalniceanu, 050107 (Romania)

    2014-04-01

    Titania nanotubes (TNTs) were prepared by anodization on different substrates (titanium, Ti6Al4V and Ti6Al7Nb alloys) in ethylene glycol and glycerol. The influence of the applied potential and processing time on the nanotube diameter and length is analyzed. The as-formed nanotube layers are amorphous but they become crystalline when subjected to subsequent thermal treatment in air at 550 °C; TNT layers grown on titanium and Ti6Al4V alloy substrates consist of anatase and rutile, while those grown on Ti6Al7Nb alloy consist only of anatase. The nanotube layers grown on Ti6Al7Nb alloy are less homogeneous, with supplementary islands of smaller diameter nanotubes, spread across the surface. Better adhesion and proliferation of osteoblasts was found for the nanotubes grown on all three substrates by comparison to an unprocessed titanium plate. The sensitivity towards bovine alkaline phosphatase was investigated mainly by electrochemical impedance spectroscopy in relation to the crystallinity, the diameter and the nature of the anodization electrolyte of the TNT/Ti samples. The measuring capacity of the annealed nanotubes of 50 nm diameter grown in glycerol was demonstrated and the corresponding calibration curve was built for the concentration range of 0.005–0.1 mg/mL. - Highlights: • Titania nanotubes (TNTs) on Ti, Ti6Al4V and Ti6Al7Nb substrates were prepared. • Quantitative dependences of anodization conditions on TNT features were established. • Morphology and electrochemical tests revealed inhomogeneity of TNT/Ti6Al7Nb films. • Particular characteristics of TNT films induce electrochemical sensitivity to ALP. • Annealed TNT/Ti impedimetric sensitivity towards ALP was demonstrated and quantified.

  12. Titanium for salt water service

    International Nuclear Information System (INIS)

    Titanium has potential as major material of construction in desalination plants, in condensers and heat exchangers, in view of its excellent corrosion resistance to salt water upto at least 120deg C. The advantages of titanium in such applications are brought out. The various specific problems such as pitting, crevice and galvanic corrosion and the preventive methods, for adopting titanium have been discussed. The hydriding problem can be overcome by suitably controlling the operating parameters such as temperature and surface preparation. A case has been made to prove the economic viability of titanium in comparison to Al-brass and Cu-Ni alloy. The future of titanium seems to be very promising in view of the negligible tube failures and outages. (auth.)

  13. Highly porous PEGylated Bi2S3 nano-urchins as a versatile platform for in vivo triple-modal imaging, photothermal therapy and drug delivery.

    Science.gov (United States)

    Li, Zhenglin; Hu, Ying; Chang, Manli; Howard, Kenneth A; Fan, Xuelei; Sun, Ye; Besenbacher, Flemming; Yu, Miao

    2016-09-21

    Biocompatible single-component nanoplatforms simultaneously integrating multiple therapeutic functions with multiple imaging modes are desirable for anticancer treatments. Herein, elaborately-designed highly porous PEGylated bismuth sulfide nano-urchins (Bi2S3-PEG NUs) have been successfully synthesized by using Bi2O3 nanospheres as the sacrificial template via the hydrothermal process. It is demonstrated that the Bi2S3-PEG NUs possess high compatibility, stability, X-ray attenuation ability, near-infrared (NIR) absorbance and photothermal conversion capability, without noticeable toxicity. Based on both in vitro and in vivo results, the product shows excellent performance in highly effective photothermal therapy (PTT) guided by triple-modal imaging, including X-ray computed tomography (CT), and photoacoustic (PA) and infrared thermal (IRT) imaging, without noticeable toxicity in vivo. Importantly, the NUs are highly porous with a high specific surface area and copious mesopores, providing high loading capacity to accommodate drugs (or guest biomolecules) for further applications in chemotherapy and other additional functions. Doxorubicin is loaded as an example, showing a rather high loading capacity (∼37.9%) together with a bimodal on-demand pH/photothermal-sensitive drug release property. Such fascinating multifunctional nanoagents may have considerable applications in antitumor diagnosis and therapy in the clinic. PMID:27545304

  14. Beta titanium alloys and their role in the titanium industry

    Science.gov (United States)

    Bania, Paul J.

    1994-07-01

    The class of titanium alloys generically referred to as the beta alloys is arguably the most versatile in the titanium family. Since these alloys offer the highest strength-to-weight ratios and deepest hardenability of all titanium alloys, one might expect them to compete favorably for a variety of aerospace applications. To the contrary, however, except for one very successful application (Ti-13V-11Cr-3Al on the SR-71), the beta alloys have remained a very small segment of the industry. As a perspective on this situation, this article reviews some past and present applications of titanium alloys. It also descibes some unique new alloys and applications that promise to reverse historical trends.

  15. Diffusion bonding of titanium-titanium aluminide-alumina sandwich

    Energy Technology Data Exchange (ETDEWEB)

    Wickman, H.A.; Chin, E.S.C. [Army Research Lab., Watertown, MA (United States); Biederman, R.R. [Worcester Polytechnic Inst., MA (United States)

    1995-12-31

    Diffusion bonding of a metallic-intermetallic-ceramic sandwich is of interest for potential armor applications. Low cost titanium, titanium diboride reinforced titanium aluminide (Ti-48at.%Al), and aluminum oxide are diffusion bonded in a vacuum furnace between 1,000 C and 1,400 C. Metallographic examination of the prior bonding interface showed excellent metallurgical coupling between the Ti-48at.%Al composite and the low cost Ti. A series of microstructures representative of phases consistent with a hypothetical Ti-Al-B phase diagram is visible. The alumina-Ti-48at.%Al interfacial bond is achieved through penetration of titanium-aluminum phases into the existing alumina porosity. A detailed microstructural analysis identifying mechanisms of interfacial bonding will be presented for each interfacial zone.

  16. Electrochemical process of titanium extraction

    Institute of Scientific and Technical Information of China (English)

    CH. RVS. NAGESH; C. S. RAMACHANDRAN

    2007-01-01

    A wide variety of processes are being pursued by researchers for cost effective extraction of titanium metal. Electrochemical processes are promising due to simplicity and being less capital intensive. Some of the promising electrochemical processes of titanium extraction were reviewed and the results of laboratory scale experiments on electrochemical reduction of TiO2 granules were brought out. Some of the kinetic parameters of the reduction process were discussed while presenting the quality improvements achieved in the experimentation.

  17. Low cost titanium--myth or reality

    Energy Technology Data Exchange (ETDEWEB)

    Turner, Paul C.; Hartman, Alan D.; Hansen, Jeffrey S.; Gerdemann, Stephen J.

    2001-01-01

    In 1998, approximately 57,000 tons of titanium metal was consumed in the form of mill products (1). Only about 5% of the 4 million tons of titanium minerals consumed each year is used to produce titanium metal, with the remainder primarily used to produce titanium dioxide pigment. Titanium metal production is primarily based on the direct chlorination of rutile to produce titanium tetrachloride, which is then reduced to metal using the Kroll magnesium reduction process. The use of titanium is tied to its high strength-to-weight ratio and corrosion resistance. Aerospace is the largest application for titanium, and titanium cost has prevented its use in non-aerospace applications including the automotive and heavy vehicle industries.

  18. Tuning anatase and rutile phase ratios and nanoscale surface features by anodization processing onto titanium substrate surfaces.

    Science.gov (United States)

    Roach, M D; Williamson, R S; Blakely, I P; Didier, L M

    2016-01-01

    Both the anatase (A) and rutile (R) phases of titanium oxide have shown enhanced antimicrobial and bioactivity levels but the specific A/R phase ratio needed for the best results is still unknown. In this study titanium samples were anodized to produce specific ratios of anatase and rutile phases within the oxide layers. Specific ratios produced included maximum A minimum R, minimum A maximum R, 50% A 50% R, minimum A minimum R, and a non-anodized titanium control group. Samples were characterized for phase distributions within the oxide layers, surface porosity, corrosion resistance, and bioactivity. Results indicated the targeted phase ratios were reproducibly achieved during the anodization process. Samples containing the highest levels of anatase showed the largest individual pore sizes, but a lower overall percent porosity value compared to samples containing higher rutile levels. EBSD examination of the anodized layer cross-sections provided valuable new spatial information on the distribution of anatase and rutile phases within the anodized layers. Highly porous oxide layers showed significantly higher corrosion rates compared to non-anodized titanium, but no significant differences were shown in the icorr values between samples containing primarily anatase phase, samples containing primarily rutile phase, and samples containing an approximate 50:50 mixture of the two phases. Minimum A minimum R samples showed substantially less porosity compared to the other anodization groups, a significantly lower oxide thickness, and comparable corrosion rates to non-anodized titanium. All samples within the study showed apatite production in simulated body fluid within the seven day test period indicating enhanced bioactivity.

  19. Cell response of anodized nanotubes on titanium and titanium alloys.

    Science.gov (United States)

    Minagar, Sepideh; Wang, James; Berndt, Christopher C; Ivanova, Elena P; Wen, Cuie

    2013-09-01

    Titanium and titanium alloy implants that have been demonstrated to be more biocompatible than other metallic implant materials, such as Co-Cr alloys and stainless steels, must also be accepted by bone cells, bonding with and growing on them to prevent loosening. Highly ordered nanoporous arrays of titanium dioxide that form on titanium surface by anodic oxidation are receiving increasing research interest due to their effectiveness in promoting osseointegration. The response of bone cells to implant materials depends on the topography, physicochemistry, mechanics, and electronics of the implant surface and this influences cell behavior, such as adhesion, proliferation, shape, migration, survival, and differentiation; for example the existing anions on the surface of a titanium implant make it negative and this affects the interaction with negative fibronectin (FN). Although optimal nanosize of reproducible titania nanotubes has not been reported due to different protocols used in studies, cell response was more sensitive to titania nanotubes with nanometer diameter and interspace. By annealing, amorphous TiO2 nanotubes change to a crystalline form and become more hydrophilic, resulting in an encouraging effect on cell behavior. The crystalline size and thickness of the bone-like apatite that forms on the titania nanotubes after implantation are also affected by the diameter and shape. This review describes how changes in nanotube morphologies, such as the tube diameter, the thickness of the nanotube layer, and the crystalline structure, influence the response of cells.

  20. Interfacial oxidations of pure titanium and titanium alloys with investments.

    Science.gov (United States)

    Ban, S; Watanabe, T; Mizutani, N; Fukui, H; Hasegawa, J; Nakamura, H

    2000-12-01

    External oxides of a commercially pure titanium (cpTi), Ti6Al4V alloy, and an experimental beta-type titanium alloy (Ti 53.4 wt%, Nb 29 wt%, Ta 13 wt%, and Zr 4.6 wt%) were characterized after heating to 600, 900, 1150, and 1400 degrees C in contact with three types of investments (alumina cement, magnesia cement, and phosphate-bonded) in air. XRD studies demonstrated that MgO, Li2TiO3 and/or Li2Ti3O7 were formed through reactions with the metal and the constituents in the magnesia cement-investment after heating to 900, 1150, and 1400 degrees C. Except for these conditions, TiO2 (rutile) was only formed on cpTi. For titanium alloys, the other components apart from Ti also formed simple and complex oxides such as Al2O3 and Al2TiO5 on Ti6Al4V, and Zr0.25Ti0.75Nb2O7 on the beta-type titanium alloy. However, no oxides containing V or Ta were formed. These results suggest that the constituents of titanium alloys reacted with the investment oxides and atmospheric oxygen to form external oxides due to the free energy of oxide formation and the concentration of each element on the metal surface.

  1. Titanium nanostructures for biomedical applications

    Science.gov (United States)

    Kulkarni, M.; Mazare, A.; Gongadze, E.; Perutkova, Š.; Kralj-Iglič, V.; Milošev, I.; Schmuki, P.; Iglič, A.; Mozetič, M.

    2015-02-01

    Titanium and titanium alloys exhibit a unique combination of strength and biocompatibility, which enables their use in medical applications and accounts for their extensive use as implant materials in the last 50 years. Currently, a large amount of research is being carried out in order to determine the optimal surface topography for use in bioapplications, and thus the emphasis is on nanotechnology for biomedical applications. It was recently shown that titanium implants with rough surface topography and free energy increase osteoblast adhesion, maturation and subsequent bone formation. Furthermore, the adhesion of different cell lines to the surface of titanium implants is influenced by the surface characteristics of titanium; namely topography, charge distribution and chemistry. The present review article focuses on the specific nanotopography of titanium, i.e. titanium dioxide (TiO2) nanotubes, using a simple electrochemical anodisation method of the metallic substrate and other processes such as the hydrothermal or sol-gel template. One key advantage of using TiO2 nanotubes in cell interactions is based on the fact that TiO2 nanotube morphology is correlated with cell adhesion, spreading, growth and differentiation of mesenchymal stem cells, which were shown to be maximally induced on smaller diameter nanotubes (15 nm), but hindered on larger diameter (100 nm) tubes, leading to cell death and apoptosis. Research has supported the significance of nanotopography (TiO2 nanotube diameter) in cell adhesion and cell growth, and suggests that the mechanics of focal adhesion formation are similar among different cell types. As such, the present review will focus on perhaps the most spectacular and surprising one-dimensional structures and their unique biomedical applications for increased osseointegration, protein interaction and antibacterial properties.

  2. Titanium nanostructures for biomedical applications

    International Nuclear Information System (INIS)

    Titanium and titanium alloys exhibit a unique combination of strength and biocompatibility, which enables their use in medical applications and accounts for their extensive use as implant materials in the last 50 years. Currently, a large amount of research is being carried out in order to determine the optimal surface topography for use in bioapplications, and thus the emphasis is on nanotechnology for biomedical applications. It was recently shown that titanium implants with rough surface topography and free energy increase osteoblast adhesion, maturation and subsequent bone formation. Furthermore, the adhesion of different cell lines to the surface of titanium implants is influenced by the surface characteristics of titanium; namely topography, charge distribution and chemistry. The present review article focuses on the specific nanotopography of titanium, i.e. titanium dioxide (TiO2) nanotubes, using a simple electrochemical anodisation method of the metallic substrate and other processes such as the hydrothermal or sol-gel template. One key advantage of using TiO2 nanotubes in cell interactions is based on the fact that TiO2 nanotube morphology is correlated with cell adhesion, spreading, growth and differentiation of mesenchymal stem cells, which were shown to be maximally induced on smaller diameter nanotubes (15 nm), but hindered on larger diameter (100 nm) tubes, leading to cell death and apoptosis. Research has supported the significance of nanotopography (TiO2 nanotube diameter) in cell adhesion and cell growth, and suggests that the mechanics of focal adhesion formation are similar among different cell types. As such, the present review will focus on perhaps the most spectacular and surprising one-dimensional structures and their unique biomedical applications for increased osseointegration, protein interaction and antibacterial properties. (topical review)

  3. Production of titanium dioxide

    International Nuclear Information System (INIS)

    Titanium dioxide pigments provide whiteness and opacity to a vast range of everyday products from coatings and plastics to inks and even cosmetics and food. Manufacturing takes place using two different processes - the so called 'sulphate' and 'chloride' routes - to produce more than 4.5 million t per year worldwide. Both routes start from impure TiO2 based feedstocks containing moderately enhanced concentrations of radionuclides of natural origin. Experts from the TiO2 production industry and feedstock suppliers are assisting the IAEA in the development of a Safety Report concerning exposure to NORM within the TiO2 industry. The data assessment shows that, for both process routes, most of the radioactivity reports to the solid process wastes and there are no areas of concern related to products, co-products or liquid or gaseous effluents for production units operating to current environmental standards. Risk assessments for the landfill disposal of solid process waste similarly did not indicate any areas of concern where current waste management practices were followed. Process deposits, typically scale material, can exhibit enhanced activity concentrations of radium. Specific management practices such as controlled vessel entry to restrict worker exposure to these materials may be necessary. With such measures, it is considered unlikely that a worker would receive an annual effective dose exceeding 1 mSv. (author)

  4. Plasmonic titanium nitride nanostructures for perfect absorbers

    DEFF Research Database (Denmark)

    Guler, Urcan; Li, Wen-Wei; Kinsey, Nathaniel;

    2013-01-01

    We propose a metamaterial based perfect absorber in the visible region, and investigate the performance of titanium nitride as an alternative plasmonic material. Numerical and experimental results reveal that titanium nitride performs better than gold as a plasmonic absorbing material...

  5. Thermodynamic analysis of production of high purity titanium by thermal decomposition of titanium iodide

    Institute of Scientific and Technical Information of China (English)

    CHEN Xiao-hu; WANG Hua; LIU Yi-min; FANG Min

    2009-01-01

    High purity titanium was prepared by thermal decomposition of titanium iodide. The feasible synthetic route and optimum decompositon temperaure were obtained by thermodynamic analysis in the process of thermal decomposition of titanium iodide and nucleation growth theory. The temperature for the formation of titanium iodide is in the range of 800-900 K, at which a large amount of titanium iodide vapour can be obtained. The decomposition temperature of titanium iodide is in the range of 1 300-1 500 K, at which a favourable decomposition rate can be achieved. The experiment results show that the purity of the produced titanium is more than 99.995%.

  6. Fiber reinforced titanium alloy composites

    International Nuclear Information System (INIS)

    The more important titanium matrix composites studied to date are composed of titanium alloy matrices, such as Ti 6Al--4V, reinforced with filaments of boron, silicon carbide, or sapphire, as well as with wires of beryllium or refractory metal alloys. The primary fabrication techniques for these materials involve vacuum hot pressing at 1300 to 16000F, alternate layers of titanium alloy matrix foils, and suitably aligned filament mats. The more ductile reinforcements such as beryllium, have been incorporated into titanium matrix composites by coextrusion. Fabrication of composite gas turbine engine fan blades from both boron (SiC coated) and beryllium reinforced Ti 6Al--4V alloy is described. Feasibility studies have been made in the fabrication of Boron/Ti 6Al--4V composite rings for possible gas turbine engine disc applications. Mechanical properties of various titanium matrix composite systems are presented and demonstrate the attractive elevated temperature properties of some systems to 10000F. (35 fig, 6 tables) (U.S.)

  7. Cementless anatomical prosthesis for the treatment of 3-part and 4-part proximal humerus fractures: cadaver study and prospective clinical study with minimum 2 years followup

    Directory of Open Access Journals (Sweden)

    Obert Laurent

    2016-01-01

    Full Text Available Introduction: The purpose of this study was to evaluate the functional and radiological outcomes of a cementless, trauma-specific locked stem for 3- and 4-part proximal humeral fractures. Materials and methods: This study consisted of two parts: a cadaver study with 22 shoulders and a multicenter prospective clinical study of 23 fracture patients evaluated at least 2 years after treatment. In the cadaver study, the locked stem (HumelockTM, FX Solutions and its instrumentation were evaluated. In the clinical study, five senior surgeons at four different hospitals performed the surgical procedures. An independent surgeon evaluated the patients using clinical (Constant score, QuickDASH and radiological (X-rays, CT scans outcome measures. Results: The cadaver study allowed us to validate the height landmarks relative to the pectoralis major tendon. In the clinical study, at the review, abduction was 95° (60–160, forward flexion was 108° (70–160, external rotation (elbow at body was 34° (0–55, the QuickDASH was 31 (4.5–59, the overall Constant score was 54 (27–75, and the weighted Constant score was 76 (31.5–109. Discussion: This preliminary study of hemiarthroplasty (HA with a locked stem found results that were at least equivalent to published series. As all patients had at least a 2-year follow-up, integration of the locked stem did not cause any specific complications. These results suggest that it is possible to avoid using cement when hemiarthroplasty is performed for the humeral stem. This implant makes height adjustment and transosseous suturing of the tuberosities more reproducible.

  8. Estudo da estabilidade dos componentes na artroplastia total do joelho sem cimento Study on implant stability in cementless total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Luís Eduardo Passarelli Tírico

    2012-01-01

    Full Text Available OBJETIVO: Comparar dois métodos de avaliação da estabilidade dos componentes tibial e femoral nas artroplastias de joelho não cimentadas com plataforma rotatória. MÉTODOS: Para isso foram avaliados 20 pacientes (20 joelhos através de uma análise de radiografias dinâmicas com intensificador de imagem e manobras de estresse em varo e valgo, que foram comparadas com radiografias estáticas em frente e perfil dos joelhos, analisadas por dois cirurgiões experientes, cegos um em relação ao outro. RESULTADOS: Os resultados das análises estáticas e dinâmicas foram comparados e demonstraram forte correlação estatística (pObjetives: Determine the stability of tibial and femoral components of 20 cementless knee arthroplasties with rotating platform. METHODS: The 20 patients (20 knees underwent an analysis of dynamic radiographs with an image amplifier and maneuvers of varus and valgus which were compared to static frontal and lateral radiographs of the knees and analyzed by two experienced surgeons in a double-blind way. RESULTS: We could observe in this study that both methods showed very similar results for the stability of the tibial and femoral components (p<0,001 using the Kappa method for comparison. CONCLUSION: The tibial component was more unstable in relation to the femoral component in both static and dynamic studies. Level of evidence IV, Case Series.

  9. Titanium, Sinusitis, and the Yellow Nail Syndrome

    OpenAIRE

    Berglund, Fredrik; Carlmark, Björn

    2010-01-01

    Yellow nail syndrome is characterized by nail changes, respiratory disorders, and lymphedema. In a yellow nail patient with a skeletal titanium implant and with gold in her teeth, we found high levels of titanium in nail clippings. This study aims to examine the possible role of titanium in the genesis of the yellow nail syndrome. Nail clippings from patients with one or more features of the yellow nail syndrome were analyzed by energy dispersive X-ray fluorescence. Titanium was regularly fou...

  10. Lightweight Protective Coatings For Titanium Alloys

    Science.gov (United States)

    Wiedemann, Karl E.; Taylor, Patrick J.; Clark, Ronald K.

    1992-01-01

    Lightweight coating developed to protect titanium and titanium aluminide alloys and titanium-matrix composite materials from attack by environment when used at high temperatures. Applied by sol-gel methods, and thickness less than 5 micrometers. Reaction-barrier and self-healing diffusion-barrier layers combine to protect titanium alloy against chemical attack by oxygen and nitrogen at high temperatures with very promising results. Can be extended to protection of other environmentally sensitive materials.

  11. 21 CFR 73.575 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.575 Section 73.575 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL LISTING OF COLOR ADDITIVES EXEMPT FROM CERTIFICATION Foods § 73.575 Titanium dioxide. (a) Identity. (1) The color additive titanium dioxide is synthetically...

  12. 21 CFR 73.3126 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.3126 Section 73.3126 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL LISTING OF COLOR ADDITIVES EXEMPT FROM CERTIFICATION Medical Devices § 73.3126 Titanium dioxide. (a) Identity and specifications. The color additive titanium...

  13. 40 CFR 180.1195 - Titanium dioxide.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Titanium dioxide. 180.1195 Section 180.1195 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS... Titanium dioxide. Titanium dioxide is exempted from the requirement of a tolerance for residues in or...

  14. 21 CFR 73.2575 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.2575 Section 73.2575 Food and... ADDITIVES EXEMPT FROM CERTIFICATION Cosmetics § 73.2575 Titanium dioxide. (a) Identity and specifications. The color additive titanium dioxide shall conform in identity and specifications to the...

  15. 21 CFR 73.1575 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.1575 Section 73.1575 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL LISTING OF COLOR ADDITIVES EXEMPT FROM CERTIFICATION Drugs § 73.1575 Titanium dioxide. (a) Identity and specifications. (1) The color additive titanium dioxide...

  16. Adaptive mesh refinement in titanium

    Energy Technology Data Exchange (ETDEWEB)

    Colella, Phillip; Wen, Tong

    2005-01-21

    In this paper, we evaluate Titanium's usability as a high-level parallel programming language through a case study, where we implement a subset of Chombo's functionality in Titanium. Chombo is a software package applying the Adaptive Mesh Refinement methodology to numerical Partial Differential Equations at the production level. In Chombo, the library approach is used to parallel programming (C++ and Fortran, with MPI), whereas Titanium is a Java dialect designed for high-performance scientific computing. The performance of our implementation is studied and compared with that of Chombo in solving Poisson's equation based on two grid configurations from a real application. Also provided are the counts of lines of code from both sides.

  17. Photonuclear reactions on titanium isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Belyshev, S. S. [Moscow State University (Russian Federation); Dzhilavyan, L. Z. [Russian Academy of Sciences, Institute for Nuclear Research (Russian Federation); Ishkhanov, B. S.; Kapitonov, I. M. [Moscow State University (Russian Federation); Kuznetsov, A. A., E-mail: kuznets@depni.sinp.msu.ru; Orlin, V. N.; Stopani, K. A. [Moscow State University, Skobeltsyn Institute of Nuclear Physics (Russian Federation)

    2015-03-15

    The photodisintegration of titanium isotopes in the giant-dipole-resonance energy region is studied by the photon-activation method. Bremsstrahlung photons whose spectrum has the endpoint energy of 55 MeV is used. The yields and integrated cross sections are determined for photoproton reactions on the titanium isotopes {sup 47,48,49,50}Ti. The respective experimental results are compared with their counterparts calculated on the basis of the TALYS code and a combined photonucleon-reaction model. The TALYS code disregards the isospin structure of the giant dipole resonance and is therefore unable to describe the yield of photoproton reactions on the heavy titanium isotopes {sup 49,50}Ti.

  18. Mechanical properties of titanium connectors.

    Science.gov (United States)

    Neo, T K; Chai, J; Gilbert, J L; Wozniak, W T; Engelman, M J

    1996-01-01

    The tensile mechanical properties of welded titanium joints were studied, and intact titanium was used as controls. Welded joints were fabricated with either a stereographic laser-welding technique or a gas tungsten arc welding technique. The effect of heat treatment following a simulated porcelain application was also investigated. Heat-treated laser welds had significantly lower ultimate tensile strengths. Heat treatment had no effect on the modulus of elasticity or elongation, but generally significantly decreased the yield strength of the titanium specimens. The gas tungsten are welding specimens had significantly higher yield strengths and elastic moduli than the other two groups. The elongation of the control specimens was significantly greater than the elongation of the gas tungsten arc welding specimens, which was in turn significantly higher than that of the laser-welded specimens. PMID:8957877

  19. The use of a modular titanium endoprosthesis in skeletal reconstructions after bone tumor resections: method presentation and analysis of 37 cases

    Directory of Open Access Journals (Sweden)

    Croci Alberto Tesconi

    2000-01-01

    Full Text Available We analyzed 37 patients who underwent segmental wide resection of bone tumors and reconstruction with a modular titanium endoprosthesis at the Orthopaedic Oncology Group, between 1992 and 1998. Twelve patients were male and 25 were female, with a mean age of 30 years (9 - 81. The mean follow-up was 14 months (2 - 48. The diagnoses were: osteosarcoma (14 cases, metastatic carcinoma (10, Ewing's sarcoma (4, giant cell tumor (4, malignant fibrous histiocytoma (3, chondrosarcoma (1, and aneurysmal bone cyst (1. Eleven articulated total knee, 8 partial proximal femur with bipolar acetabulum, 8 partial proximal humerus, 3 total femur, 2 partial proximal tibia, 2 diaphyseal femur, 2 diaphyseal humerus, and 1 total proximal femur with cementless acetabulum endoprosthesis implant procedures were done. The complications related to the procedure included: infection (5 cases, dislocation (3, module loosening (1, and ulnar nerve paresthesia (1. We used the following criteria for the clinical evaluation: presence of pain, range of motion, reconstruction stability, surgical and oncologic complications, and patient acceptance. The results were good in 56.8% of the cases, regular in 32.4% and poor in 10.8%.

  20. Synthesis of nano-particle and highly porous conducting perovskites from simple in situ sol–gel derived carbon templating process

    Indian Academy of Sciences (India)

    Wei Zhou; Ran Ran; Zongping Shao; Wanqin Jin; Nanping Xu

    2010-08-01

    Nano-sized La0.6Sr0.4Co0.2Fe0.8O$_{3–\\delta}$ (LSCF) and La0.8Sr0.2MnO$_{3–\\delta}$ (LSM) oxides were synthesized by a simple in situ sol–gel derived carbon templating process. Nano-sized LSCF–carbon and LSM–carbon composites were first obtained with a grain size of 20–30 nm. Further calcination of the obtained composites under air resulted in the nano-sized pure-phase perovskites with crystalline size of as small as 14 nm. Such a decrease in crystalline size of perovskite via the indirect calcination process was ascribed to the suppressing effect of carbon in the grain growth of perovskite. Furthermore, when the in situ created carbon was applied as a template for pore forming, a highly porous perovskite sintering body packing from the nano-sized perovskite oxide was obtained.

  1. A highly porous NiO/polyaniline composite film prepared by combining chemical bath deposition and electro-polymerization and its electrochromic performance

    Science.gov (United States)

    Xia, X. H.; Tu, J. P.; Zhang, J.; Wang, X. L.; Zhang, W. K.; Huang, H.

    2008-11-01

    A highly porous NiO/polyaniline (PANI) composite film was prepared on ITO glass by combining the chemical bath deposition and electro-polymerization methods, successively. The porous NiO film acts as a template for the preferential growth of PANI along NiO flakes, and the NiO/PANI composite film has an intercrossing net-like morphology. The electrochromic performance of the NiO/PANI composite film was investigated in 1 M LiClO4+1 mM HClO4/propylene carbonate (PC) by means of transmittance, cyclic voltammetry (CV) and chronoamperometry (CA) measurements. The NiO/PANI thin film exhibits a noticeable electrochromism with reversible color changes from transparent yellow to purple and presents quite good transmittance modulation with a variation of transmittance up to 56% at 550 nm. The porous NiO/polyaniline (PANI) composite film also shows good reaction kinetics with fast switching speed, and the response time for oxidation and reduction is 90 and 110 ms, respectively.

  2. A highly porous NiO/polyaniline composite film prepared by combining chemical bath deposition and electro-polymerization and its electrochromic performance

    International Nuclear Information System (INIS)

    A highly porous NiO/polyaniline (PANI) composite film was prepared on ITO glass by combining the chemical bath deposition and electro-polymerization methods, successively. The porous NiO film acts as a template for the preferential growth of PANI along NiO flakes, and the NiO/PANI composite film has an intercrossing net-like morphology. The electrochromic performance of the NiO/PANI composite film was investigated in 1 M LiClO4+1 mM HClO4/propylene carbonate (PC) by means of transmittance, cyclic voltammetry (CV) and chronoamperometry (CA) measurements. The NiO/PANI thin film exhibits a noticeable electrochromism with reversible color changes from transparent yellow to purple and presents quite good transmittance modulation with a variation of transmittance up to 56% at 550 nm. The porous NiO/polyaniline (PANI) composite film also shows good reaction kinetics with fast switching speed, and the response time for oxidation and reduction is 90 and 110 ms, respectively.

  3. Rapid synthesis of monodispersed highly porous spinel nickel cobaltite (NiCo{sub 2}O{sub 4}) electrode material for supercapacitors

    Energy Technology Data Exchange (ETDEWEB)

    Naveen, A. Nirmalesh, E-mail: nirmalesh.naveen@gmail.com; Selladurai, S. [Ionics Laboratory, Department of Physics, Anna University, Chennai-600025 (India)

    2015-06-24

    Monodispersed highly porous spinel nickel cobaltite electrode material was successfully synthesized in a short time using combustion technique. Single phase cubic nature of the spinel nickel cobaltite with average crystallite size of 24 nm was determined from X-ray diffraction study. Functional groups present in the compound were determined from FTIR study and it further confirms the spinel formation. FESEM images reveal the porous nature of the prepared material and uniform size distribution of the particles. Electrochemical evaluation was performed using Cyclic Voltammetry (CV) technique, Chronopotentiometry (CP) and Electrochemical Impedance Spectroscopy (EIS). Results reveal the typical pseudocapacitive behaviour of the material. Maximum capacitance of 754 F/g was calculated at the scan rate of 5 mV/s, high capacitance was due to the unique porous morphology of the electrode. Nyquist plot depicts the low resistance and good electrical conductivity of nickel cobaltite. It has been found that nickel cobaltite prepared by this typical method will be a potential electrode material for supercapcitor application.

  4. Lactobacillusassisted synthesis of titanium nanoparticles

    Directory of Open Access Journals (Sweden)

    Jha Anal

    2007-01-01

    Full Text Available AbstractAn eco-friendlylactobacillussp. (microbe assisted synthesis of titanium nanoparticles is reported. The synthesis is performed at room temperature. X-ray and transmission electron microscopy analyses are performed to ascertain the formation of Ti nanoparticles. Individual nanoparticles as well as a number of aggregates almost spherical in shape having a size of 40–60 nm are found.

  5. Nanodispersed boriding of titanium alloy

    International Nuclear Information System (INIS)

    The problem of improving the operational reliability of machines is becoming increasingly important due to the increased mechanical, thermal and other loads on the details. There are many surface hardening methods for machines parts which breakdown begins with surface corruption. The most promising methods are chemical-thermal treatment. The aim of this work is to study the impact of boriding on the structure and properties of titanium alloy. Materials and Methods: The material of this study is VT3-1 titanium alloy. The boriding were conducted using nanodispersed powder blend based on boric substances. It is established that boriding of paste compounds allows obtaining the surface hardness within 30 - 29 GPa and with declining to 27- 26 GPa in layer to the transition zone (with total thickness up to 110 μm) owing to changes of the layer phase composition where T2B, TiB, TiB2 titanium borides are formed. The increasing of chemical-thermal treatment time from 15 minutes to 2 hours leads to thickening of the borated layer (30 - 110 μm) and transition zone (30 - 190 μm). Due to usage of nanodispersed boric powder, the boriding duration is decreasing in 2 - 3 times. This allows saving time and electric energy. The developed optimal mode of boriding the VT3-1 titanium alloy allows obtaining the required operational characteristics and to combine the saturation of the surface layer with atomic boron and hardening

  6. Nanodispersed boriding of titanium alloy

    Directory of Open Access Journals (Sweden)

    Kateryna O. Kostyk

    2015-12-01

    Full Text Available The problem of improving the operational reliability of machines is becoming increasingly important due to the increased mechanical, thermal and other loads on the details. There are many surface hardening methods for machines parts which breakdown begins with surface corruption. The most promising methods are chemo-thermal treatment. Aim: The aim of this work is to study the impact of boriding on the structure and properties of titanium alloy. Materials and Methods: The material of this study is VT3-1 titanium alloy. The boriding were conducted using nanodispersed powder blend based on boric substances. Results: It is established that boriding of paste compounds allows obtaining the surface hardness within 30...29 GPa and with declining to 27...26 GPa in layer to the transition zone (with total thickness up to 110 μm owing to changes of the layer phase composition where Ti2B, TiB, TiB2 titanium borides are formed. The increasing of chemical-thermal treatment time from 15 minutes to 2 hours leads to thickening of the borated layer (30...110 µm and transition zone (30...190 µm. Conclusions: Due to usage of nanodispersed boric powder, the boriding duration is decreasing in 2...3 times. This allows saving time and electric energy. The developed optimal mode of boriding the VT3-1 titanium alloy allows obtaining the required operational characteristics and to combine the saturation of the surface layer with atomic boron and hardening.

  7. Effect of titanium content and aging temperature on the properties of uranium-titanium alloys

    International Nuclear Information System (INIS)

    The mechanical properties and microstructures of four uranium-titanium alloys were examined as functions of titanium content and aging temperature. Titanium alloy content was varied from 0.41 to 0.79 weight percent. Aging temperatures from 350 to 4500C (all for six hours) were evaluated for each alloy in addition to tests in the unaged conditions. Titanium and aging temperature were both shown to be strong effects in determining alloy properties. It was determined that the uranium-0.41 weight percent titanium alloy underwent extensive age-hardening even though the alloy did not exhibit a martensitic microstructure characteristic of the alloys richer in titanium

  8. Highly porous ionic rht metal-organic framework for H2 and CO2 storage and separation: A molecular simulation study

    KAUST Repository

    Babarao, Ravichandar

    2010-07-06

    The storage and separation of H2 and CO2 are investigated in a highly porous ionic rht metal-organic framework (rht-MOF) using molecular simulation. The rht-MOF possesses a cationic framework and charge-balancing extraframework NO3 - ions. Three types of unique open cages exist in the framework: rhombicuboctahedral, tetrahedral, and cuboctahedral cages. The NO3 - ions exhibit small mobility and are located at the windows connecting the tetrahedral and cuboctahedral cages. At low pressures, H2 adsorption occurs near the NO 3 - ions that act as preferential sites. With increasing pressure, H2 molecules occupy the tetrahedral and cuboctahedral cages and the intersection regions. The predicted isotherm of H2 at 77 K agrees well with the experimental data. The H2 capacity is estimated to be 2.4 wt % at 1 bar and 6.2 wt % at 50 bar, among the highest in reported MOFs. In a four-component mixture (15:75:5:5 CO2/H 2/CO/CH4) representing a typical effluent gas of H 2 production, the selectivity of CO2/H2 in rht-MOF decreases slightly with increasing pressure, then increases because of cooperative interactions, and finally decreases as a consequence of entropy effect. By comparing three ionic MOFs (rht-MOF, soc-MOF, and rho-ZMOF), we find that the selectivity increases with increasing charge density or decreasing free volume. In the presence of a trace amount of H2O, the interactions between CO2 and NO3 - ions are significantly shielded by H2O; consequently, the selectivity of CO 2/H2 decreases substantially. © 2010 American Chemical Society.

  9. Antimicrobial titanium/silver PVD coatings on titanium

    Directory of Open Access Journals (Sweden)

    Thull Roger

    2006-03-01

    Full Text Available Abstract Background Biofilm formation and deep infection of endoprostheses is a recurrent complication in implant surgery. Post-operative infections may be overcome by adjusting antimicrobial properties of the implant surface prior to implantation. In this work we described the development of an antimicrobial titanium/silver hard coating via the physical vapor deposition (PVD process. Methods Coatings with a thickness of approximately 2 μm were deposited on titanium surfaces by simultaneous vaporisation of both metals in an inert argon atmosphere with a silver content of approximately 0.7 – 9% as indicated by energy dispersive X-ray analysis. On these surfaces microorganisms and eukaryotic culture cells were grown. Results The coatings released sufficient silver ions (0.5–2.3 ppb when immersed in PBS and showed significant antimicrobial potency against Staphylococcus epidermis and Klebsiella pneumoniae strains. At the same time, no cytotoxic effects of the coatings on osteoblast and epithelial cells were found. Conclusion Due to similar mechanical performance when compared to pure titanium, the TiAg coatings should be suitable to provide antimicrobial activity on load-bearing implant surfaces.

  10. Carbon nanotube-based coatings on titanium

    Indian Academy of Sciences (India)

    Elzbieta Dlugon; Wojciech Simka; Aneta Fraczek-Szczypta; Wiktor Niemiec; Jaroslaw Markowski; Marzena Szymanska; Marta Blazewicz

    2015-09-01

    This paper reports results of the modification of titanium surface with multiwalled carbon nanotubes (CNTs). The Ti samples were covered with CNTs via electrophoretic deposition (EPD) process. Prior to EPD process, CNTs were functionalized by chemical treatment. Mechanical, electrochemical and biological properties of CNT-covered Ti samples were studied and compared to those obtained for unmodified titanium surface. Atomic force microscopy was used to investigate the surface topography. To determine micromechanical characteristics of CNT-covered metallic samples indentation tests were conducted. Throughout electrochemical studies were performed in order to characterize the impact of the coating on the corrosion of titanium substrate. In vitro experiments were conducted using the human osteoblast NHOst cell line. CNT layers shielded titanium from corrosion gave the surface-enhanced biointegrative properties. Cells proliferated better on the modified surface in comparison to unmodified titanium. The deposited layer enhanced cell adhesion and spreading as compared to titanium sample.

  11. ROUGH SURFACES OF TITANIUM AND TITANIUM ALLOYS FOR IMPLANTS AND PROSTHESES

    OpenAIRE

    Conforto, Egle; Aronsson, Bjorn-Owe; Salito, A.; Crestou, Catherine; Caillard, Daniel

    2004-01-01

    Titanium and titanium alloys for dental implants and hip prostheses were surface-treated and/or covered by metallic or ceramic rough layers after being submitted to sand blasting. The goal of these treatments is to improve the surface roughness and, consequently, the osteointegration, the fixation and the stability of the implant. The microstructure of titanium and titanium alloys submitted to these treatments has been studied and correlated to their mechanical behavior. As treated/ covered a...

  12. Recycling potential of titanium alloys

    International Nuclear Information System (INIS)

    This study examines just how long one must contain radioactive titanium before it can be safely reprocessed. It was assumed that the spent first wall and blanket structural material would be completely reprocessed in a standard manufacturing facility capable of both primary and secondary fabrication. It was found that reprocessing could occur when the chemical hazard associated with inhalation was greater than the hazard associated with inhalating the same amount of radioactive species. This conclusion allowed the use of the threshold limiting value (TLV) to set a limit on the airborne concentration of the elements. Then by calculating the time required for that amount of material to decay to the same diluent factor indicated by the biological hazard potential (BHP) in air, the time for reprocessing was determined. Based on these assumptions, it was determined that it is feasible to think of titanium, and some of its alloying elements as being recyclable in a relatively short time period

  13. INVESTIGATION OF COMBUSTION IN TITANIUM-FERROSILICON SYSTEM

    OpenAIRE

    Shatokhin, Igor; Bigeev, Vahit; Shaymardanov, Kamil; Manashev, Ildar

    2013-01-01

    Results of self-sustaining combustion process in the titanium-ferrosilicon system investigations are presented. These data were used for experimental-industrial technology developing of production ferro silico titanium with high titanium content for steel alloying.

  14. Dissimilar Welding of Titanium Alloys to Steels

    OpenAIRE

    Gao, Yefei; TSUMURA, Takuya; NAKATA, Kazuhiro

    2012-01-01

    This review summarizes the dissimilar welding of titanium alloys to steels over a period of ten recent years, involving the welding processes which are used for the dissimilar welding of titanium alloys to steels, the mechanical properties of the joints and the discussion for the forming mechanism of the interface. Reducing the formation of brittle intermetallic compound (IMC) is a key requirement in the dissimilar welding of titanium alloys to steels, because the strength of the welding join...

  15. New Policies on Titanium Import and Production

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    <正> In order to crack down the smuggling of tita-nium products,improve the production and op-eration orders and guarantee a healthy devel-opment of the titanium industry in China,theState Economics and Trade Commission,theMinistry of Commerce,the General Admini-stration of Customs and four other governmentdepartments have jointly issued a Circular onthe Administration of Import,Production andOperation for Titanium Products.The circularstipulates as follows:

  16. Production of weldments from sintered titanium alloys

    OpenAIRE

    Kapustyan, A. YE.; A. V. Ovchinnikov; Vakulenko, I. A.

    2014-01-01

    Purpose. Limited application of details from powder titanium alloys is connected with the difficulties in obtaining of long-length blanks, details of complex shape and large size. We can solve these problems by applying the welding production technology. For this it is necessary to conduct a research of the structure and mechanical properties of welded joints of sintered titanium alloys produced by flash welding. Methodology. Titanium industrial powders, type PT5-1 were used as original subst...

  17. PRODUCTION OF WELDMENTS FROM SINTERED TITANIUM ALLOYS

    OpenAIRE

    A. YE. Kapustyan; A. V. Ovchinnikov; Vakulenko, I. A.

    2014-01-01

    Purpose. Limited application of details from powder titanium alloys is connected with the difficulties in obtaining of long-length blanks, details of complex shape and large size. We can solve these problems by applying the welding production technology. For this it is necessary to conduct a research of the structure and mechanical properties of welded joints of sintered titanium alloys produced by flash welding. Methodology. Titanium industrial powders, type PT5-1 were used as original subst...

  18. Gait analysis after total knee arthroplasty with cemented versus cementless type%骨水泥型与非骨水泥型全膝关节置换后的步态差异

    Institute of Scientific and Technical Information of China (English)

    张旻; 江澜; 沈晓艳

    2011-01-01

    背景:全膝关节置换已经被证明是一种有效治疗膝骨性关节炎的方法,但是不同类型的全膝关节置换假体固定方式术后所产生的膝关节下肢生物力学差异至今仍不明确.目的:通过三维步态分析骨水泥固定和非骨水泥固定两种不同的全膝关节置换术后患者的膝关节生物力学差异.方法:分别选取骨水泥型全膝关节置换以及非骨水泥型全膝关节置换患者各16例,通过测力台以及三维步态分析系统比较2组患者术前以及术后3个月的膝关节生物力学变化并进行对比.结果与结论:与手术前相比两组患者术后步速及步长均明显增加,支撑相在整个步态周期中的百分比明显减小, 膝关节屈在支撑相及摆动相中最大屈曲角度均明显增加,膝关节外翻角度增加.两种患者术后膝关节内翻角度以及膝关节内收力矩均明显减小.提示,骨水泥型与非骨水泥型全膝关节置换术均能有效改善膝骨性关节炎患者的步行能力以及下肢关节功能,两者间未见明显生物力学差异.%BACKGROUND: Total knee arthroplasty (TKA) has been proved to be a very effective method for patients with knee osteoarthritis. But the biomedical changes at knee joint between two different types of TKA (cemented and cementless) after operation remain not clear.OBJECTIVE: To explore the different biomechanical changes between the cemented and cementless TKA through three-dimensional gait analysis.METHODS: A total of 16 knee osteoarthritis patients treated with cemented TKA and 16 with cementless TKA were included.Force plates and three-dimensional gait analysis system were used to compare differences in biomechanics before and 3 months after operations.RESULTS AND CONCLUSION: Both groups showed significant increased walking speed and stride length, but decreased percentage of stance phase in gait cycle after operation, significant increased knee flexion angle in stance phase and swing

  19. Laser repair hardfacing of titanium alloy turbine

    OpenAIRE

    A. Klimpel; D. Janicki; A. Lisiecki; A. Rzeźnikiewicz

    2011-01-01

    Purpose: of this paper: work out repair technology of worn abutments of aircraft jet engine blades forged of titanium alloy WT3-1.Design/methodology/approach: The study were based on the analysis of laser HPDL powder surfacing of titanium alloy plates using wide range chemical composition consumables of titanium alloys and mixtures of pure titanium and spherical powder of WC indicated that very hard and highest quality deposits are provided by powder mixture of 40-50%Ti+60-50%WC.Findings: It ...

  20. 2005 Xi'an International Titanium Conference

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    @@ First Circular Call for Papers In the 98' Xi'an International Titanium Conference (XITC'98), more than 300 representatives of the research and industry circles from 12 countries were gathered in Xi'an to exchange the new progress on titanium R&D and industrialization. XITC'98played an important role in promoting titanium R&D for the world, especially for China. In order to let the people engaged in titanium industry know more Chinese and the world titanium industry, promote the exchange and cooperation of the world titanium circle, we decide to hold the 2005 Xi'an International titanium Conference (XITC'05), which will be held on October 16~19, 2005 in Xi'an, China. The conference will provide a forum on the exchange and discussion of new ideas and achievements related to the aspects of titanium technology and industry in recent years. At the same time, the 12th China National Conference on Titanium will be held on October 19~23, 2005 in the same place after XITC'05.

  1. Appcelerator Titanium patterns and best practices

    CERN Document Server

    Pollentine, Boydlee

    2013-01-01

    The book takes a step-by-step approach to help you understand CommonJS and Titanium architecture patterns, with easy to follow samples and plenty of in-depth explanations If you're an existing Titanium developer or perhaps a new developer looking to start off your Titanium applications "the right way", then this book is for you. With easy to follow examples and a full step-by-step account of architecting a sample application using CommonJS and MVC, along with chapters on new features such as ACS, you'll be implementing enterprise grade Titanium solutions in no time. You should have some JavaSc

  2. Titanium alloys Russian aircraft and aerospace applications

    CERN Document Server

    Moiseyev, Valentin N

    2005-01-01

    This text offers previously elusive information on state-of-the-art Russian metallurgic technology of titanium alloys. It details their physical, mechanical, and technological properties, as well as treatments and applications in various branches of modern industry, particularly aircraft and aerospace construction. Titanium Alloys: Russian Aircraft and Aerospace Applications addresses all facets of titanium alloys in aerospace and aviation technology, including specific applications, fundamentals, composition, and properties of commercial alloys. It is useful for all students and researchers interested in the investigation and applications of titanium.

  3. Titanium Matrix Composite Pressure Vessel Project

    Data.gov (United States)

    National Aeronautics and Space Administration — For over 15 years, FMW Composite Systems has developed Metal Matrix Composite manufacturing methodologies for fabricating silicon-carbide-fiber-reinforced titanium...

  4. Seam-welded titanium tube as well as titanium tubesheet for all-titanium condenser of power plants

    International Nuclear Information System (INIS)

    Most of the thermal and nuclear power plants in Japan are located on the coast line, and steam turbine condenser and heat exchanger use a great quantity of sea water for cooling. This paper describes about thin wall welded tube for all-titanium condenser, development of technology for manufacturing titanium tubesheet, and the present situation of application

  5. [Experimental research on porcelain fused to the surface of pure titanium and titanium alloys].

    Science.gov (United States)

    Wang, D; Ai, S; Xu, J

    1995-07-01

    Titanium material has been widely used in prosthodontics since the end of 1980s. However, the research on porcelain fused to the surfaces of titanium material was quite few. This article introduced the technological process of low-fusing dental porcelain--Ceratin fused to pure titanium and titanium alloys. The values of the bond strength of Ceratin and titanium substrates were obtained by shearing test with INSTRON Model-1185. The average value of the shearing strength between TA2 and Ceratin was 31. 01MPa. The corresponding value between TC4 and Ceratin was 33.73MPa. The interface between Ceratin and titanium substrate was observed with scanning electron microscope (SEM). The results of this research proposed that it is hopeful that Ceratin is used as special procelain with titanium material.

  6. Minimal stress shielding with a Mallory-Head titanium femoral stem with proximal porous coating in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Lombardi Adolph V

    2009-12-01

    Full Text Available Abstract Background As longevity of cementless femoral components enters the third decade, concerns arise with long-term effects of fixation mode on femoral bone morphology. We examined the long-term consequences on femoral remodeling following total hip arthroplasty with a porous plasma-sprayed tapered titanium stem. Methods Clinical data and radiographs were reviewed from a single center for 97 randomly selected cases implanted with the Mallory-Head Porous femoral component during primary total hip arthroplasty. Measurements were taken from preoperative and long-term follow-up radiographs averaging 14 years postoperative. Average changes in the proximal, middle and diaphyseal zones were determined. Results On anteroposterior radiographs, the proximal cortical thickness was unchanged medially and the lateral zone increased 1.3%. Middle cortical thickness increased 4.3% medially and 1.2% laterally. Distal cortical thickness increased 9.6% medially and 1.9% laterally. Using the anteroposterior radiographs, canal fill at 100 mm did not correlate with bony changes at any level (Spearman's rank correlation coefficient of -0.18, 0.05, and 0.00; p value = 0.09, 0.67, 0.97. On lateral radiographs, the proximal cortical thickness increased 1.5% medially and 0.98% laterally. Middle cortical thickness increased 2.4% medially and 1.3% laterally. Distal cortical thickness increased 3.5% medially and 2.1% laterally. From lateral radiographs, canal fill at 100 mm correlated with bony hypertrophy at the proximal, mid-level, and distal femur (Spearman's rank correlation coefficient of 0.85, 0.33, and 0.28, respectively; p value = 0.001, 0.016, and 0.01, respectively. Conclusion Stress shielding is minimized with the Mallory-Head titanium tapered femoral stem with circumferential proximal plasma-sprayed coating in well-fixed and well-functioning total hip arthroplasty. Additionally, the majority of femora demonstrated increased cortical thickness in all zones

  7. Impaction grafting in the femur in cementless modular revision total hip arthroplasty: a descriptive outcome analysis of 243 cases with the MRP-TITAN revision implant

    Directory of Open Access Journals (Sweden)

    Wimmer Matthias D

    2013-01-01

    .1% after 8.7 years]. Radiologic evaluation showed no significant change in axial implant migration (4.3% vs. 9.3%; p = 0.19 but a significant reduction in proximal stress shielding (5.7% vs. 17.9%; p  Conclusion We present the largest analysis of the impaction grafting technique in combination with cementless distal diaphyseal stem fixation published so far. Our data provides initial evidence of improved bone regeneration after graft augmentation of metaphyseal bone defects. The data suggests that proximal metaphyseal graft augmentation is beneficial for large metaphyseal bone defects (Paprosky types IIC and III and stem diameters of 17 mm and above. Due to the limitations of a retrospective and descriptive study the level of evidence remains low and prospective trials should be conducted.

  8. Casting of Titanium and its Alloys

    OpenAIRE

    R. L. Saha; K. T. Jacob

    1986-01-01

    Titaniuni and its alloys have many applications in aerospace, marine and other engineering industries. Titanium requires special melting techniques because of its high reactivity at elevated temperatures and needs special mould materials and methods for castings. This paper reviews the development of titanium casting technology.

  9. Casting of Titanium and its Alloys

    Directory of Open Access Journals (Sweden)

    R. L. Saha

    1986-04-01

    Full Text Available Titaniuni and its alloys have many applications in aerospace, marine and other engineering industries. Titanium requires special melting techniques because of its high reactivity at elevated temperatures and needs special mould materials and methods for castings. This paper reviews the development of titanium casting technology.

  10. Mineral resource of the month: titanium

    Science.gov (United States)

    Gambogi, Joseph

    2011-01-01

    Titanium is hip - at least when it comes to airplanes and jewelry. Known for its high strength-to weight ratio and its resistance to corrosion, titanium and its alloys can also be found in everything from knee replacements to eyeglass frames to baseball bats to fighter planes.

  11. Amorphouslike diffraction pattern in solid metallic titanium

    DEFF Research Database (Denmark)

    Wang, Y.; Fang, Y.Z.; Kikegawa, T.;

    2005-01-01

    Amorphouslike diffraction patterns of solid elemental titanium have been detected under high pressure and high temperature using in situ energy-dispersive x-ray diffraction and a multianvil press. The onset pressure and the temperature of formation of amorphous titanium is found to be close...

  12. Appcelerator Titanium business application development cookbook

    CERN Document Server

    Bahrenberg, Benjamin

    2013-01-01

    Presented in easy to follow, step by step recipes, this guide is designed to lead you through the most important aspects of application design.Titanium developers who already have a basic knowledge of working with Appcelerator Titanium but want to further develop their knowledge for use with business applications

  13. Titanium tetrachloride burns to the eye.

    OpenAIRE

    Chitkara, D K; McNeela, B. J.

    1992-01-01

    We present eight cases of chemical burns of the eyes from titanium tetrachloride, an acidic corrosive liquid. However it causes severe chemical burns which have a protracted course and features more akin to severe alkali burns. Injuries related to titanium tetrachloride should be treated seriously and accordingly appropriate management is suggested.

  14. Titanium plasma produced by a nitrogen laser

    International Nuclear Information System (INIS)

    Titanium plasmas produced in vacuum and in air by radiation from a nitrogen laser focused onto a solid titanium target are studied spectroscopically. The energy deposition is more effective than in other cases since the wavelength of the laser is in the vicinity of Ti resonance lines. (orig.)

  15. The present status of dental titanium casting

    Science.gov (United States)

    Okabe, Toru; Ohkubo, Chikahiro; Watanabe, Ikuya; Okuno, Osamu; Takada, Yukyo

    1998-09-01

    Experimentation in all aspects of titanium casting at universities and industries throughout the world for the last 20 years has made titanium and titanium-alloy casting nearly feasible for fabricating sound cast dental prostheses, including crowns, inlays, and partial and complete dentures. Titanium casting in dentistry has now almost reached the stage where it can seriously be considered as a new method to compete with dental casting using conventional noble and base-metal alloys. More than anything else, the strength of titanium’s appeal lies in its excellent biocompatibility, coupled with its comparatively low price and abundant supply. Research efforts to overcome some problems associated with this method, including studies on the development of new titanium alloys suitable for dental use, will continue at many research sites internationally.

  16. Stress-corrosion cracking of titanium alloys.

    Science.gov (United States)

    Blackburn, M. J.; Feeney, J. A.; Beck, T. R.

    1973-01-01

    In the light of research material published up to May 1970, the current understanding of the experimental variables involved in the stress-corrosion cracking (SCC) behavior of titanium and its alloys is reviewed. Following a brief summary of the metallurgy and electrochemistry of titanium alloys, the mechanical, electrochemical, and metallurgical parameters influencing SCC behavior are explored with emphasis on crack growth kinetics. Macro- and microfeatures of fractures are examined, and it is shown that many transgranular SCC failures exhibit morphological and crystallographic features similar to mechanical cleavage failures. Current SCC models are reviewed with respect to their ability to explain the observed SCC behavior of titanium and its alloys. Possible methods for eliminating or minimizing stress corrosion hazards in titanium or titanium alloy components are described.

  17. [Use of titanium alloys for medical instruments].

    Science.gov (United States)

    Feofilov, R N; Chirkov, V K; Levin, M V

    1977-01-01

    On the ground of an analysis into properties of titanium and its alloys the fields of their possible utilization for making various medical instruments are proposed. Because of their insufficient hardness and wear-resistance the titanium alloys cannot be recommended for making medical instruments with thin cutting edges. For the reasons of their insufficient strength, low wear-resistance and substandard modulus of elasticity, it is inexpedient to use titanium alloys in making many types of clamping medical instruments. Nor is it advisable to employ titanium alloys in handles of the instruments, for this may lead to a contact corrosion of their working parts. The use of titanium alloys is recommended for making bone-joining members, retracting medical instruments, of the spatula and speculum types, some kinds of non-magnetic pincers and ultrasonic medical instruments.

  18. Welding and Joining of Titanium Aluminides

    Directory of Open Access Journals (Sweden)

    Jian Cao

    2014-06-01

    Full Text Available Welding and joining of titanium aluminides is the key to making them more attractive in industrial fields. The purpose of this review is to provide a comprehensive overview of recent progress in welding and joining of titanium aluminides, as well as to introduce current research and application. The possible methods available for titanium aluminides involve brazing, diffusion bonding, fusion welding, friction welding and reactive joining. Of the numerous methods, solid-state diffusion bonding and vacuum brazing have been most heavily investigated for producing reliable joints. The current state of understanding and development of every welding and joining method for titanium aluminides is addressed respectively. The focus is on the fundamental understanding of microstructure characteristics and processing–microstructure–property relationships in the welding and joining of titanium aluminides to themselves and to other materials.

  19. Synthesis and physicochemical characterization of titanium oxide and sulfated titanium oxide obtained by thermal hydrolysis of titanium tetrachloride

    Directory of Open Access Journals (Sweden)

    H. Esteban Benito

    2014-09-01

    Full Text Available This work reports the synthesis of titanium oxide (TiO2 and sulfated titanium oxide (TiO2-SO4(2- obtained by thermal hydrolysis of titanium tetrachloride. Titanium hydroxide synthesized by this method was impregnated with a 1 N H2SO4 solution, to give amounts of sulfate ions (SO4(2- of 3 and 7 wt%. The synthesized samples were dried at 120 °C during 24 h and then calcined for 3 h at 400 °C. Thermal analyses, X-ray diffraction, nitrogen physisorption, infrared spectroscopy, potentiometric titration with n-butylamine, U.V.-visible diffuse reflectance spectroscopy and scanning electron microscopy were used to characterize the materials. The results of physicochemical characterization revealed that a mixture of crystalline structures, anatase, brookite and rutile developed in the titanium oxide, stabilizing the anatase structure in the sulfated titanium oxides, and coexisting with a small amount of brookite structure. The synthesized mesoporous materials developed specific surface areas between 62 and 70 m² g-1, without detecting an important influence of sulfation on this parameter. The presence of sulfate ions improved the acidity of titanium oxide and modified the characteristics of light absorption in the 425-600 nm region, which suggests the possibility of using these materials in reactions assisted by visible light.

  20. Characterisation of titanium-titanium boride composites processed by powder metallurgy techniques

    Energy Technology Data Exchange (ETDEWEB)

    Selva Kumar, M., E-mail: sel_mcet@yahoo.co.in [Department of Mechanical Engineering, Dr. Mahalingam College of Engineering and Technology, Pollachi-642003 (India); Chandrasekar, P.; Chandramohan, P. [School of Engineering, Professional Group of Institutions, Coimbatore-641662 (India); Mohanraj, M. [Department of Mechanical Engineering, Info Institute of Engineering, Coimbatore-641107 (India)

    2012-11-15

    In this work, a detailed characterisation of titanium-titanium boride composites processed by three powder metallurgy techniques, namely, hot isostatic pressing, spark plasma sintering and vacuum sintering, was conducted. Two composites with different volume percents of titanium boride reinforcement were used for the investigation. One was titanium with 20% titanium boride, and the other was titanium with 40% titanium boride (by volume). Characterisation was performed using X-ray diffraction, electron probe micro analysis - energy dispersive spectroscopy and wavelength dispersive spectroscopy, image analysis and scanning electron microscopy. The characterisation results confirm the completion of the titanium boride reaction. The results reveal the presence of titanium boride reinforcement in different morphologies such as needle-shaped whiskers, short agglomerated whiskers and fine plates. The paper also discusses how mechanical properties such as microhardness, elastic modulus and Poisson's ratio are influenced by the processing techniques as well as the volume fraction of the titanium boride reinforcement. - Highlights: Black-Right-Pointing-Pointer Ti-TiB composites were processed by HIP, SPS and vacuum sintering. Black-Right-Pointing-Pointer The completion of Ti-TiB{sub 2} reaction was confirmed by XRD, SEM and EPMA studies. Black-Right-Pointing-Pointer Hardness and elastic properties of Ti-TiB composites were discussed. Black-Right-Pointing-Pointer Processing techniques were compared with respect to their microstructure.

  1. Explosive Growth in China’s Titanium Industry in 2007

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>The year 2007 has marked an important mile- stone in China’s titanium and titanium- processing industry with a doubled or redou- bled output of titanium or titanium alloys. China has become one of the world’s most

  2. Adsorption of hydrogen in titanium

    International Nuclear Information System (INIS)

    In this work the absorption of hydrogen in titanium plates using a constant volume system has been realized. The changes of temperature and pressure were used to monitor the progress of the absorption. A stainless steel vacuum chamber with volume of 4,333 cm3 was used. A titanium sample of 45 x 5.4 x 0.3 cm was located in the center of the chamber. The sample was heated by an electrical source connected to the system. The sample was preconditioned with a vacuum-thermal treatment at 10-6 mbar and 800 Centigrade degrees for several days. Absorption was observed at room temperature and also at higher temperatures. The room temperature absorption was in the pressure range of 1.0 x 103 to 2.5 x 103 mbar, and other absorptions were from 180 to 630 Centigrade degrees at 3.5 x 10-1 to 1.3 x 103 mbar. It was found that the gas absorbed was function of the vacuum-thermal pre-conditioned treatment, pressure and temperature. When the first absorption was developed, additional absorptions were realized in short time. We measured the electrical resistivity of the sample in the experiments but we could not see important changes due to the absorption. (Author)

  3. DEVELOPMENT OF OXIDATION RESISTANT TITANIUM ALLOYS BY NIOBIUM ADDITION

    OpenAIRE

    Ackland, Graeme; Siemers, Carsten; Tegner, Bengt E.; Saksl, K.; Brunke, F.; Kohnke, M,

    2014-01-01

    The application of titanium alloys is limited to 550°C due to their poor oxidation resistance. It is known that the addition of niobium improves the oxidation resistance of titanium whereas elements like vanadium do not support titanium’s oxidation behaviour. Hence, the underlying mechanisms are not understood. In the present study, different binary titanium-niobium and titanium-vanadium alloys as well as commercially pure titanium were investigated. Oxidation experiments were carried out at ...

  4. Titanium Oxide: A Bioactive Factor in Osteoblast Differentiation

    OpenAIRE

    Santiago-Medina, P.; Sundaram, P.A.; Diffoot-Carlo, N.

    2015-01-01

    Titanium and titanium alloys are currently accepted as the gold standard in dental applications. Their excellent biocompatibility has been attributed to the inert titanium surface through the formation of a thin native oxide which has been correlated to the excellent corrosion resistance of this material in body fluids. Whether this titanium oxide layer is essential to the outstanding biocompatibility of titanium surfaces in orthopedic biomaterial applications is still a moot point. To study ...

  5. Study on the Forging Processes of Titanium Golf Woods Head

    Institute of Scientific and Technical Information of China (English)

    Hsu; Quang-cherng

    2002-01-01

    This paper describes the titanium forging processes a pplied in the golf club head forgings. Generally speaking, titanium has poor for geability and therefore the threshold to invest in the titanium forging operatio n is high. Process parameters have been discussed and computer simulation on the forging processes has been conducted and compared with the forging practices. N ormally, titanium rod was preferred billet on titanium golf club head forging, w hich is the case on iron head, but it is not appropr...

  6. Structure and properties of Titanium for dental implants

    OpenAIRE

    GREGER, Miroslav; Černý, Martin; Kander, Ladislav; Kliber, Jiří

    2009-01-01

    This paper describes manufacture of nano-structural titanium, its structure and properties. Nano-titanium has higher specific strength properties than ordinary (coarse-grained) titanium. Nano-titanium was produced by the equal-channel angular pressing (ETAP) process. The research it self was focused on physical base of strengthening and softening processes and developments occurring at the grain boundaries during the ECAP process at half-hot temperature. Strength of nano-titanium ...

  7. Current assisted superplastic forming of titanium alloy

    Directory of Open Access Journals (Sweden)

    Wang Guofeng

    2015-01-01

    Full Text Available Current assisted superplastic forming combines electric heating technology and superplastic forming technology, and can overcome some shortcomings of traditional superplastic forming effectively, such as slow heating rate, large energy loss, low production efficiency, etc. Since formability of titanium alloy at room temperature is poor, current assisted superplastic forming is suitable for titanium alloy. This paper mainly introduces the application of current assisted superplastic forming in the field of titanium alloy, including forming technology of double-hemisphere structure and bellows.

  8. Titanium Content Control for Bearing Steel

    Institute of Scientific and Technical Information of China (English)

    WU Wei; LIU Yue; LIU Liu; XUE Zheng-liang

    2008-01-01

    On the basis of the thermodynamic analysis and fundamental study in the laboratory,the equilibrium of the Ti-Al-O system was investigated.The results showed that the equilibrium titanium content in the steel increased with the increase in the soluble aluminum content in the steel and the TiO2 content in the slag.Although the slag basicity decreased and Al2O3 content in the slag increased,the titanium content increased.Based on these results,the BOF smelting process of low titanium bearing steel was put forward.

  9. Titanium exposure and yellow nail syndrome

    Directory of Open Access Journals (Sweden)

    Ali Ataya

    2015-01-01

    Full Text Available Yellow nail syndrome is a rare disease of unclear etiology. We describe a patient who develops yellow nail syndrome, with primary nail and sinus manifestations, shortly after amalgam dental implants. A study of the patient's nail shedding showed elevated nail titanium levels. The patient had her dental implants removed and had complete resolution of her sinus symptoms with no change in her nail findings. Since the patient's nail findings did not resolve we do not believe titanium exposure is a cause of her yellow nail syndrome but perhaps a possible relationship exists between titanium exposure and yellow nail syndrome that requires further studies.

  10. Stress corrosion cracking of titanium alloys

    Science.gov (United States)

    Statler, G. R.; Spretnak, J. W.; Beck, F. H.; Fontana, M. G.

    1974-01-01

    The effect of hydrogen on the properties of metals, including titanium and its alloys, was investigated. The basic theories of stress corrosion of titanium alloys are reviewed along with the literature concerned with the effect of absorbed hydrogen on the mechanical properties of metals. Finally, the basic modes of metal fracture and their importance to this study is considered. The experimental work was designed to determine the effects of hydrogen concentration on the critical strain at which plastic instability along pure shear directions occurs. The materials used were titanium alloys Ti-8Al-lMo-lV and Ti-5Al-2.5Sn.

  11. Synthesis of Titanium Dioxide Nanocrystals with Controlled Crystal- and Micro-structures from Titanium Complexes

    OpenAIRE

    Makoto Kobayashi; Hideki Kato; Masato Kakihana

    2013-01-01

    Selective synthesis of titanium dioxide (TiO2) polymorphs including anatase, rutile, brookite and TiO2(B) by solvothermal treatment of water-soluble titanium complexes is described with a special focus on their morphological control. The utilization of water-soluble titanium complexes as a raw material allowed us to employ various additives in the synthesis of TiO2. As a result, the selective synthesis of the polymorphs, as well as diverse morphological control, was achieved.

  12. Titanium

    DEFF Research Database (Denmark)

    Fage, Simon W; Muris, Joris; Jakobsen, Stig S;

    2016-01-01

    and medical implants, personal care products, and foods. Despite being considered to be highly biocompatible relative to other metals, Ti is released in the presence of biological fluids and tissue, especially under certain circumstances, which seem to be more likely with regard to dental implants. Although...... evaluation. Reports on clinical allergy and adverse events have rarely been published. Whether this is because of unawareness of possible adverse reactions to this specific metal, difficulties in detection methods, or the metal actually being relatively safe to use, is still unresolved....

  13. [Comparison of the biological tolerance of titanium and titanium alloys in human gingiva cell cultures].

    Science.gov (United States)

    Hehner, B; Heidemann, D

    1989-01-01

    Mirror-finished solid specimens of pure titanium and the titanium alloys Ti-6Al-4V as well as Ti-5Al-2.5Fe showed no effects on the growth behavior and cell morphology of human gingival epithelial cell and fibroblast cultures. The growth of the cells contacting all three materials was uninhibited. SEM revealed growth of fibroblasts on the surfaces of the specimens, too. No differences could be found between the biocompatibility of titanium alloys and that of pure titanium. The formation of a stable surface oxide layer providing resistance to corrosion may be decisive.

  14. Neutron scattering and models: Titanium

    Energy Technology Data Exchange (ETDEWEB)

    Smith, A.B.

    1997-07-01

    Differential neutron elastic-scattering cross sections of elemental titanium were measured from 4.5 {r_arrow} 10.0 MeV in incident energy increments of {approx} 0.5 MeV. At each energy the measurements were made at forty or more scattering angles distributed between {approx} 17 and 160{degree}. Concurrently, differential neutron inelastic-scattering cross sections were measured for observed excitations of 0.975 {+-} 0.034, 1.497 {+-} 0.033, 2.322 {+-} 0.058, 3.252 {+-} 0.043, 3.700 {+-} 0.093, 4.317 {+-} 0.075 and 4.795 {+-} 0.100 MeV. All of the observed inelastically-scattered neutron groups were composites of contributions from several isotopes and/or levels. The experimental results were used to develop energy-average optical, statistical and coupled-channels models.

  15. Preparation of highly porous NiO–gadolinium-doped ceria nano-composite powders by one-pot glycine nitrate process for anode-supported tubular solid oxide fuel cells

    Directory of Open Access Journals (Sweden)

    Seung-Young Park

    2014-12-01

    Full Text Available Highly porous NiO–gadolinium-doped ceria (GDC nano-composite powders are synthesized by a one-pot glycine nitrate process and applied to the fabrication of Ni–YSZ (yttria-stabilized zirconia-supported tubular solid oxide fuel cells (SOFCs with a cell configuration of Ni–YSZ/Ni/Ni–GDC/GDC/LSCF (La0.6Sr0.4Co0.2Fe0.8O3−δ–GDC/LSCF. The power density of the cell is as high as 413 mW cm−2 at 600 °C, which is 1.37 times higher than that of an identically configured cell fabricated using ball milling-derived NiO–GDC powders (301 mW cm−2. The high porosity of the powders and the good mixing between the NiO and GDC primary nanoparticles due to the abrupt combustion of the precursors effectively suppress the densification, coarsening, and agglomeration of NiO and GDC particles during sintering, resulting in a highly porous Ni–GDC anode layer with good dispersion of Ni and GDC particles and a cell with significantly enhanced power density.

  16. Titanium Heat Pipe Thermal Plane Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Thermacore Inc. proposes an innovative titanium heat pipe thermal plane for passive thermal control of individual cells within a fuel cell stack. The proposed...

  17. Titanium Heat Pipe Thermal Plane Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of the Phase II program is to complete the development of the titanium heat pipe thermal plane and establish all necessary steps for production of...

  18. Titanium nitride nanoparticles for therapeutic applications

    DEFF Research Database (Denmark)

    Guler, Urcan; Kildishev, Alexander V.; Boltasseva, Alexandra;

    2014-01-01

    Titanium nitride nanoparticles exhibit plasmonic resonances in the biological transparency window where high absorption efficiencies can be obtained with small dimensions. Both lithographic and colloidal samples are examined from the perspective of nanoparticle thermal therapy. © 2014 OSA....

  19. Advanced Surface Engineering of Titanium Alloys

    Institute of Scientific and Technical Information of China (English)

    H. Dong

    2000-01-01

    Despite their outstanding combination of properties, titanium and its alloys are very susceptible to severe adhesive wear in rubbing with most engineering surfaces and can exhibit poorcorrosion resistance in some aggressive environments. Surface engineering research centred at the University of Birmingham has been focused on creating designer surfaces for titanium components via surface engineering.Great progress has been made recently through the development of such advanced surface engineering techniques as thermal oxidation, palladium-treated thermal oxidation, oxygen boost diffusion and duplex systems.Such advances thus provide scope for designing titanium components for a diversified range of engineering application, usually as direct replacements for steel components. By way of example, some of the successful steps towards titanium designer surfaces are demonstrated. To data, the potential of these advanced technologies has been realised first in auto-sport and off-shore industrials.

  20. Corrosion resistance of titanium alloys for dentistry

    International Nuclear Information System (INIS)

    Titanium and its alloys belong to biomaterials which the application scope in medicine increases. Some properties of the alloys, such as high mechanical strength, low density, low Young's modulus, high corrosion resistance and good biotolerance decide about it. The main areas of the application of titanium and its alloys are: orthopedics and traumatology, cardiosurgery, faciomaxillary surgery and dentistry. The results of investigations concerning the corrosion resistance of the technical titanium and Ti6Al14V alloy and comparatively a cobalt alloy of the Vitallium type in the artificial saliva is presented in the work. Significantly better corrosion resistance of titanium and the Ti6Al14V than the Co-Cr-Mo alloy was found. (author)

  1. Microstructure and Slip Character in Titanium Alloys

    OpenAIRE

    Banerjee, D.; Williams, J. C.

    1986-01-01

    Influence of microstructures in titanium alloys on the basic parameters of deformation behaviour such as slip character, slip length and slip intensity have been explored. Commercial titanium alloys contain the hexagonal close packed (alpha) and body centred cubic (bita) phases. Slip in these individual phases is shown to be dependent on the nature of alloying elements through their effect on phase stability as related to decomposition into ordered or w structures. When alpha and bita coexist...

  2. Titanium dioxide nanoparticles: Occupational exposure limits

    OpenAIRE

    Anna Maria Świdwińska-Gajewska; Sławomir Czerczak

    2014-01-01

    Titanium dioxide (TiO2) is produced in Poland as a high production volume chemical (HPVC). It is used mainly as a pigment for paints and coatings, plastics, paper, and also as additives to food and pharmaceuticals. Titanium dioxide nanoparticles are increasingly applied in cosmetics, textiles and plastics as the ultraviolet light blocker. This contributes to a growing occupational exposure to TiO2 nanoparticles. Nanoparticles are potentially responsible for the most adverse effects of titaniu...

  3. TEFLON VS TITANIUM PROSTHESES IN STAPES SURGERY

    OpenAIRE

    Rajesh Vishwakarma; Simple Patadia; Pratibha Goswami; Kalpesh Patel; Dipesh Darji

    2014-01-01

    BACKGROUND: Otosclerosis is one of the most leading causes of conductive hearing loss with intact tympanic membrane in adults. Stapes prostheses have seen many changes in its shape, design and material. Both Teflon and Titanium prostheses used in this study having different method of application are reviewed in detail. OBJECTIVE: To compare the outcomes of use of Teflon and Titanium prostheses in stapedotomy surgery in patients with conductive hearing loss. STUDY DESIGN: Prospective ...

  4. Functional studies of calcium enriched titanium surfaces.

    OpenAIRE

    Mihoc, R. I.

    2007-01-01

    There exists a clinical requirement for dental implants which will enhance the speed of achievement of osseointegration, its maintenance, and biological and physical properties. Whilst commercially pure titanium remains the material of choice for implant fabrication, a promising approach to enhancing its performance is the surface incorporation of metallic ions, or alkali modification of titanium. Osteoblast behaviour adjacent to the implant is a key factor in osseointegration and it is known...

  5. PRODUCTION OF WELDMENTS FROM SINTERED TITANIUM ALLOYS

    Directory of Open Access Journals (Sweden)

    A. YE. Kapustyan

    2014-04-01

    Full Text Available Purpose. Limited application of details from powder titanium alloys is connected with the difficulties in obtaining of long-length blanks, details of complex shape and large size. We can solve these problems by applying the welding production technology. For this it is necessary to conduct a research of the structure and mechanical properties of welded joints of sintered titanium alloys produced by flash welding. Methodology. Titanium industrial powders, type PT5-1 were used as original substance. Forming of blanks, whose chemical composition corresponded to BT1-0 alloy, was carried out using the powder metallurgy method. Compounds were obtained by flash welding without preheating. Microstructural investigations and mechanical tests were carried out. To compare the results investigations of BT1-0 cast alloy were conducted. Findings. Samples of welded joints of sintered titanium blanks from VT1-0 alloy using the flash butt welding method were obtained. During welding the microstructure of basic metal consisting of grains of an a-phase, with sizes 40...70 mkm, is transformed for the seam weld and HAZ into the lamellar structure of an a-phase. The remaining pores in seam weld were practically absent; in the HAZ their size was up to 2 mkm, with 30 mkm in the basic metal. Attainable level of mechanical properties of the welded joint in sintered titanium alloys is comparable to the basic metal. Originality. Structure qualitative changes and attainable property complex of compounds of sintered titanium alloys, formed as a result of flash butt welding were found out. Practical value. The principal possibility of high-quality compounds obtaining of sintered titanium alloys by flash welding is shown. This gives a basis for wider application of sintered titanium alloys due to long-length blanks production that are correspond to deformable strand semi finished product.

  6. TEFLON VS TITANIUM PROSTHESES IN STAPES SURGERY

    Directory of Open Access Journals (Sweden)

    Rajesh Vishwakarma

    2014-04-01

    Full Text Available BACKGROUND: Otosclerosis is one of the most leading causes of conductive hearing loss with intact tympanic membrane in adults. Stapes prostheses have seen many changes in its shape, design and material. Both Teflon and Titanium prostheses used in this study having different method of application are reviewed in detail. OBJECTIVE: To compare the outcomes of use of Teflon and Titanium prostheses in stapedotomy surgery in patients with conductive hearing loss. STUDY DESIGN: Prospective study SETTING: Tertiary referral centre METHODS: A prospective study of 50 patients of otosclerosis, who underwent stapedotomy at B.J.Medical College, Civil Hospital, Ahmedabad, with Teflon/Titanium prostheses, from June 2009-February 2012 was done. Follow up was done for a minimum period of 6 months. Revision cases were excluded. A comparison of prostheses was concluded by differences in AB (Air Bone Gap. RESULT: Postoperative ABG of 20db or less was seen in 96% in both groups. The mean postoperative ABGap was 8.2 dB and 11.5 dB for Teflon and Titanium group respectively. There was no statistically significance difference noted in ABGap between Teflon and Titanium pistons at 95% confidence limit at P<0.05. There was significant improvement of AC thresholds at each frequency except for above 4 kHz, in postoperative period. CONCLUSION: Both prostheses provide equal benefit to patients and there is no statistically significant difference between the uses of Teflon/Titanium prostheses. Long term results are still to be analyzed.

  7. Initial cytotoxicity of novel titanium alloys.

    Science.gov (United States)

    Koike, M; Lockwood, P E; Wataha, J C; Okabe, T

    2007-11-01

    We assessed the biological response to several novel titanium alloys that have promising physical properties for biomedical applications. Four commercial titanium alloys [Super-TIX(R) 800, Super-TIX(R) 51AF, TIMETAL(R) 21SRx, and Ti-6Al-4V (ASTM grade 5)] and three experimental titanium alloys [Ti-13Cr-3Cu, Ti-1.5Si and Ti-1.5Si-5Cu] were tested. Specimens (n = 6; 5.0 x 5.0 x 3.0 mm(3)) were cast in a centrifugal casting machine using a MgO-based investment and polished to 600 grit, removing 250 mum from each surface. Commercially pure titanium (CP Ti: ASTM grade 2) and Teflon (polytetrafluoroethylene) were used as positive controls. The specimens were cleaned and disinfected, and then each cleaned specimen was placed in direct contact with Balb/c 3T3 fibroblasts for 72 h. The cytotoxicity [succinic dehydrogenase (SDH) activity] of the extracts was assessed using the MTT method. Cytotoxicity of the metals tested was not statistically different compared to the CP Ti and Teflon controls (p > 0.05). These novel titanium alloys pose cytotoxic risks no greater than many other commonly used alloys, including commercially pure titanium. The promising short-term biocompatibility of these Ti alloys is probably due to their excellent corrosion resistance under static conditions, even in biological environments. PMID:17385227

  8. Initial cytotoxicity of novel titanium alloys.

    Science.gov (United States)

    Koike, M; Lockwood, P E; Wataha, J C; Okabe, T

    2007-11-01

    We assessed the biological response to several novel titanium alloys that have promising physical properties for biomedical applications. Four commercial titanium alloys [Super-TIX(R) 800, Super-TIX(R) 51AF, TIMETAL(R) 21SRx, and Ti-6Al-4V (ASTM grade 5)] and three experimental titanium alloys [Ti-13Cr-3Cu, Ti-1.5Si and Ti-1.5Si-5Cu] were tested. Specimens (n = 6; 5.0 x 5.0 x 3.0 mm(3)) were cast in a centrifugal casting machine using a MgO-based investment and polished to 600 grit, removing 250 mum from each surface. Commercially pure titanium (CP Ti: ASTM grade 2) and Teflon (polytetrafluoroethylene) were used as positive controls. The specimens were cleaned and disinfected, and then each cleaned specimen was placed in direct contact with Balb/c 3T3 fibroblasts for 72 h. The cytotoxicity [succinic dehydrogenase (SDH) activity] of the extracts was assessed using the MTT method. Cytotoxicity of the metals tested was not statistically different compared to the CP Ti and Teflon controls (p > 0.05). These novel titanium alloys pose cytotoxic risks no greater than many other commonly used alloys, including commercially pure titanium. The promising short-term biocompatibility of these Ti alloys is probably due to their excellent corrosion resistance under static conditions, even in biological environments.

  9. Oxidation resistant coating for titanium alloys and titanium alloy matrix composites

    Science.gov (United States)

    Brindley, William J. (Inventor); Smialek, James L. (Inventor); Rouge, Carl J. (Inventor)

    1992-01-01

    An oxidation resistant coating for titanium alloys and titanium alloy matrix composites comprises an MCrAlX material. M is a metal selected from nickel, cobalt, and iron. X is an active element selected from Y, Yb, Zr, and Hf.

  10. Development and Evaluation of Titanium Spacesuit Bearings

    Science.gov (United States)

    Rhodes, Richard; Battisti, Brian; Ytuarte, Raymond, Jr.; Schultz, Bradley

    2016-01-01

    The Z-2 Prototype Planetary Extravehicular Space Suit Assembly is a continuation of NASA's Z-series of spacesuits, designed with the intent of meeting a wide variety of exploration mission objectives, including human exploration of the Martian surface. Incorporating titanium bearings into the Z-series space suit architecture allows us to reduce mass by an estimated 23 lbs per suit system compared to the previously used stainless steel bearing race designs, without compromising suit functionality. There are two obstacles to overcome when using titanium for a bearing race- 1) titanium is flammable when exposed to the oxygen wetted environment inside the space suit and 2) titanium's poor wear properties are often challenging to overcome in tribology applications. In order to evaluate the ignitability of a titanium space suit bearing, a series of tests were conducted at White Sands Test Facility (WSTF) that introduced the bearings to an extreme test profile, with multiple failures imbedded into the test bearings. The testing showed no signs of ignition in the most extreme test cases; however, substantial wear of the bearing races was observed. In order to design a bearing that can last an entire exploration mission (approx. 3 years), design parameters for maximum contact stress need to be identified. To identify these design parameters, bearing test rigs were developed that allow for the quick evaluation of various bearing ball loads, ball diameters, lubricants, and surface treatments. This test data will allow designers to minimize the titanium bearing mass for a specific material and lubricant combination and design around a cycle life requirement for an exploration mission. This paper reviews the current research and testing that has been performed on titanium bearing races to evaluate the use of such materials in an enriched oxygen environment and to optimize the bearing assembly mass and tribological properties to accommodate for the high bearing cycle life for an

  11. Effect of Alkali-Acid-Heat Chemical Surface Treatment on Electron Beam Melted Porous Titanium and Its Apatite Forming Ability

    Directory of Open Access Journals (Sweden)

    Suzan Bsat

    2015-04-01

    Full Text Available Advanced additive manufacturing techniques such as electron beam melting (EBM, can produce highly porous structures that resemble the mechanical properties and structure of native bone. However, for orthopaedic applications, such as joint prostheses or bone substitution, the surface must also be bio-functionalized to promote bone growth. In the current work, EBM porous Ti6Al4V alloy was exposed to an alkali acid heat (AlAcH treatment to bio-functionalize the surface of the porous structure. Various molar concentrations (3, 5, 10M and immersion times (6, 24 h of the alkali treatment were used to determine optimal parameters. The apatite forming ability of the samples was evaluated using simulated body fluid (SBF immersion testing. The micro-topography and surface chemistry of AlAcH treated samples were evaluated before and after SBF testing using scanning electron microscopy and energy dispersive X-ray spectroscopy. The AlAcH treatment successfully modified the topographical and chemical characteristics of EBM porous titanium surface creating nano-topographical features ranging from 200–300 nm in size with a titania layer ideal for apatite formation. After 1 and 3 week immersion in SBF, there was no Ca or P present on the surface of as manufactured porous titanium while both elements were present on all AlAcH treated samples except those exposed to 3M, 6 h alkali treatment. An increase in molar concentration and/or immersion time of alkali treatment resulted in an increase in the number of nano-topographical features per unit area as well as the amount of titania on the surface.

  12. Corrosion Inhibition of Titanium in Artificial Saliva Containing Fluoride

    OpenAIRE

    Latifa KINANI; Abdelilah CHTAINI

    2007-01-01

    The objective of this study was to demonstrate the effect of eugenol on the titanium corrosion in artificial saliva enriched with eugenol at different concentration. The corrosion behaviour and titanium surface characterization were investigated by electrochemical measurements and SEM.

  13. Corrosion Inhibition of Titanium in Artificial Saliva Containing Fluoride

    OpenAIRE

    Latifa KINANI; Rachida NAJIH; Abdelilah CHTAINI

    2008-01-01

    The objective of this study was to demonstrate the effect of eugenol on the titanium corrosion in artificial saliva enriched with eugenol at different concentration. The corrosion behaviour and titanium surface characterization were investigated by electrochemical measurements and SEM.

  14. Thermodynamics Behavior of Titanium for BOF Smelting Bearing Steel

    Institute of Scientific and Technical Information of China (English)

    LIU Yue; WU Wei; LIU Liu; LIU Ming; LI Yang-zhou

    2006-01-01

    When titanium element appears in bearing steel, it is very easy to create titanium nitride inclusion, which reduces the fatigue life of bearing steel. Based on the production data of bearing steel produced by BOF, it is found that the titanium takes its source in bearing steel; the factors affecting titanium content, and the thermodynamics behavior of titanium under smelting condition were studied. The results show that the prime reasons of titanium content increment are the soluble aluminum content and the titanium oxide of slag. The comparison between the experimental data and theoretical ones shows that there is a big declination when the soluble aluminum content of steel is higher, which is caused by the nonequilibrium reaction of slag and steel. The apparent equilibrium distribution coefficient of titanium between slag and steel is obtained by use of experimental data.

  15. Speciation of titanium in solvent refined coal using SESC - INAA

    International Nuclear Information System (INIS)

    The preasphaltenes (Pa) separated from solvent refined coal (SRC-I) were fractionated by sequential elution solvent chromatography (SESC) on silica column into 10 fractions. Titanium was determined by instrumental neutron activation analysis (INAA), and was found to be concentrated in fractions 7-10. The preasphaltenes form stable complexes with bis (cyclopentadienyl) titanium(IV) dichloride (BTD), cyclopentadienyl titanium(IV) trichloride (CTT) and titanium(IV) oxide bis (acetylacetone) (TOBA). Preasphaltene titanium complexes (Pa-BTD, Pa-CTT, and Pa-TOBA) were fractionated using the SESC scheme, and the concentration of titanium in each fraction was determined. The mechanism for the reaction between titanium complexes (BTD, CTT or TOBA) and Pa was studied, and the existence of titanium phenoxide type complexes in SRC-I was proposed

  16. Colloidal Plasmonic Titanium Nitride Nanoparticles: Properties and Applications

    DEFF Research Database (Denmark)

    Guler, Urcan; Suslov, Sergey; Kildishev, Alexander V.;

    2015-01-01

    Optical properties of colloidal plasmonic titanium nitride nanoparticles are examined with an eye on their photothermal and photocatalytic applications via transmission electron microscopy and optical transmittance measurements. Single crystal titanium nitride cubic nanoparticles with an average ...

  17. Advances of Titanium Alloys and Its Biological Surface Modification

    Institute of Scientific and Technical Information of China (English)

    XU Ke-wei; HUANG Ping

    2004-01-01

    This paper reviews the past, present and future of surface modification of titanium alloy from the point of view of preparation of hard tissue replacement implants. The development of titanium alloy is also described.

  18. Engineering titanium surfaces for improving osteointegration

    Science.gov (United States)

    Lu, Xiong

    Titanium is one of the most important metallic biomedical materials in clinical applications. One of the key issues for successful application of titanium is the interaction at the interface between the titanium and the bone. The present study focuses on improving the surfaces of titanium to achieve better capability to bond with natural bone (i.e. better osteointegration). The objectives of this work include: (1) Developing microfabrication methods to produce micropatterns on titanium surfaces for promoting osteointegration; (2) Studying the calcium phosphate (Ca-P) formation on the chemical treated titanium surface and elucidating the mechanism of precipitation theoretically; and (3) Evaluating osteoconductivity of engineering titanium surfaces in vitro and in vivo. Through mask electrochemical micromachining (TMEMM), jet electrochemical micromachining (Jet-EMM) and the confined etchant layer technique (CELT) were attempted to produce micropatterns on titanium surfaces. TMEMM has a high etching rate and good reproducibility and was used to produce micro-hole arrays on Ti plates for in vivo testing. The driving force and nucleation rate of Ca-P precipitation in simulated body fluid (SBF) were analyzed based on the classical crystallization theory. SBF supersaturation with respect to HA, OCP and DCPD (dicalcium phosphate) was carefully calculated, considering all the association/dissociation reactions of related ion groups in SBF. The analysis indicates that the nucleation rate of OCP is substantially higher than that of HA, while HA is most thermodynamically stable in SBF. DCPD precipitation is thermodynamically impossible in normal SBF, unless calcium and phosphate ion concentrations of SBF increase. Osteoconduction of Ti6Al4V surfaces under various conditions, including micro-patterned, alkali-treated, micro-patterned plus alkali-treated, and surfaces without any treatment, was evaluated. TMEMM was used to fabricate micro-hole arrays on the titanium alloy

  19. Laser induced single spot oxidation of titanium

    Science.gov (United States)

    Jwad, Tahseen; Deng, Sunan; Butt, Haider; Dimov, S.

    2016-11-01

    Titanium oxides have a wide range of applications in industry, and they can be formed on pure titanium using different methods. Laser-induced oxidation is one of the most reliable methods due to its controllability and selectivity. Colour marking is one of the main applications of the oxidation process. However, the colourizing process based on laser scanning strategies is limited by the relative large processing area in comparison to the beam size. Single spot oxidation of titanium substrates is proposed in this research in order to increase the resolution of the processed area and also to address the requirements of potential new applications. The method is applied to produce oxide films with different thicknesses and hence colours on titanium substrates. High resolution colour image is imprinted on a sheet of pure titanium by converting its pixels' colours into laser parameter settings. Optical and morphological periodic surface structures are also produced by an array of oxide spots and then analysed. Two colours have been coded into one field and the dependencies of the reflected colours on incident and azimuthal angles of the light are discussed. The findings are of interest to a range of application areas, as they can be used to imprint optical devices such as diffusers and Fresnel lenses on metallic surfaces as well as for colour marking.

  20. Plasma Induced Grafting of PMMA onto Titanium Dioxide Powder

    Institute of Scientific and Technical Information of China (English)

    Zhong Shaofeng; Meng Yuedong; Ou Qiongrong; Xu Xu

    2005-01-01

    Grafting of polymer of methyl methacrylate (PMMA) onto titanium dioxide powder is investigated in this paper. The graft polymerization reaction is induced by dielectric-barrierdischarge produced N2 plasma treatment of titanium dioxide surfaces. IR, XPS and TGA results show that PMMA is grafted onto the surfaces of titanium dioxide powder. And crystal structure of the titanium dioxide powder observed with XRD spectra is unchanged after plasma graft polymerization.

  1. The Progress on Laser Surface Modification Techniques of Titanium Alloy

    Institute of Scientific and Technical Information of China (English)

    LIANG Cheng; PAN Lin; Al Ding-fei; TAO Xi-qi; XIA Chun-huai; SONG Yan

    2004-01-01

    Titanium alloy is widely used in aviation, national defence, automobile, medicine and other fields because of their advantages in lower density, corrosion resistance, and fatigue resistance etc. As titanium alloy is higher friction coefficients, weak wear resistance, bad high temperature oxidation resistance and lower biocompatibility, its applications are restricted. Using laser surface modification techniques can significantly improve the surface properties of titanium alloy. a review is given for progress on laser surface modification techniques of titanium alloy in this paper.

  2. ALLOYING OF TITANIUM BY OXYGEN DURING CHAMBER ELECTROSLAG REMELTING

    OpenAIRE

    RYABTSEV ANATOLIY D.; TROYANSKYY OLEKSANDR A.; PASHYNSKYI VOLODYMYR V.; SNIZHKO OLGA A.

    2014-01-01

    The paper presents the results of alloying titanium by oxygen in the process of chamber electroslag remelting. As an oxygen-containing ligature, we used the electrodes-satellite from the reaction mass residues mixture from the retort lid for magnesium thermal reduction of a titanium sponge, a specially prepared gaseous argon oxygen mixture containing 30% oxygen applied directly to the melting space, micro-size (10-15 mm) powder particles of titanium oxide and titanium oxide nanopowder with a ...

  3. Solvolysis of titanium tetrachloride in non-aqueous media as a method for producing titanium dioxide particles of different morphology

    OpenAIRE

    A. M Nemeryuk; M. M Lylina

    2015-01-01

    The processes of solvolysis of titanium tetrachloride in nonaqueous media were studied. The influence of the conditions of solvolysis on the size and morphology of the particles of titanium dioxide produced have been described.

  4. Individual prefabricated titanium implants and titanium mesh in skull base reconstructive surgery. A report of cases.

    Science.gov (United States)

    Schipper, J; Ridder, G J; Spetzger, U; Teszler, C B; Fradis, M; Maier, W

    2004-05-01

    Titanium implants can be shaped by traditional hand forming, press shaping, modular construction by welding, construction on full-size models shaped from CT coordinates and, most recently, by computer-assisted design and computer-assisted manufacturing (CAD/CAM) that consist in the direct prefabrication of individual implants by milling them out of a solid block of titanium. The aim of our study was to present a set of preliminary cases of an ongoing program of reconstructive procedures of the skull base using titanium implants. The subjects underwent ablative procedures of the skull base with reconstruction either by titanium mesh or individual prefabricated CAD/CAM implants. Six patients have been operated on successfully since 2000: two received prefabricated CAD/CAM titanium plates and four others underwent reconstruction with titanium mesh. The stability of CAD/CAM plates is superior to that of mesh, thus it is more useful in reconstructing large lesions of the frontal skull base and the temporal and occipital bones. Titanium mesh was successfully used for defects smaller than 100 cm(2) or where selected viscerocranial defects are complicated in design and less reproducible by CAD/CAM. The intraoperative design, shaping and adjustment characteristic of titanium mesh can be dispensed with when CAD/CAM implants are used. The 3-D data set used in the CAD/CAM process also operates in the navigated simulation and planning of the ablation contours, the latter being of great assistance in establishing the optimal future defect. As a disadvantage, CAD/CAM technology is more expensive than titanium mesh, and the process is time-consuming as it is carried out in advance of surgery.

  5. Asymmetric Catalytic Reactions Catalyzed by Chiral Titanium Complexes

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    @@ Chiral titanium complexes is very importance catalyst to asymmetric catalytic reactions. A series of catalytic systems based on titanium-chiral ligands complexes has been reported. This presentation will discuss some of our recent progress on asymmetric catalytic reactions catalyzed by chiral titanium complexes.

  6. Asymmetric Catalytic Reactions Catalyzed by Chiral Titanium Complexes

    Institute of Scientific and Technical Information of China (English)

    FENG; XiaoMing

    2001-01-01

    Chiral titanium complexes is very importance catalyst to asymmetric catalytic reactions. A series of catalytic systems based on titanium-chiral ligands complexes has been reported. This presentation will discuss some of our recent progress on asymmetric catalytic reactions catalyzed by chiral titanium complexes.  ……

  7. China Customs Removed the Import Tax on Titanium Slag

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    <正>The long waited solution to the problem relating to the import of titanium slag has finally resolved. According to China Customs report, the import of titanium slag no longer requires tax payment as from January 1, 2007. This decision will help with the healthy development of China’s titanium industry and increase China’s competitiveness in the international marketplace.

  8. Enhancing osseointegration using surface-modified titanium implants

    Science.gov (United States)

    Yang, Y.; Oh, N.; Liu, Y.; Chen, W.; Oh, S.; Appleford, M.; Kim, S.; Kim, K.; Park, S.; Bumgardner, J.; Haggard, W.; Ong, J.

    2006-07-01

    Osseointegrated dental implants are used to replace missing teeth. The success of implants is due to osseointegration or the direct contact of the implant surface and bone without a fibrous connective tissue interface. This review discusses the enhancement of osseointegration by means of anodized microporous titanium surfaces, functionally macroporous graded titanium coatings, nanoscale titanium surfaces, and different bioactive factors.

  9. Applications of Titanium Dioxide Photocatalysis to Construction Materials

    CERN Document Server

    Ohama, Yoshihiko

    2011-01-01

    Titanium dioxide photocatalysis is based on the semiconducting nature of its anatase crystal type. Construction materials with titanium photocatalyst show performances of air purification, self-cleaning, water purification, antibacterial action. This book describes principles of titanium dioxide photocatalysis, its applications to cementitious and noncementitious materials, as well as an overview of standardization of testing methods.

  10. Development and application of titanium alloy casting technology in China

    Institute of Scientific and Technical Information of China (English)

    NAN Hai; XIE Cheng-mu; ZHAO Jia-qi

    2005-01-01

    The development and research of titanium cast alloy and its casting technology, especially its application inaeronautical industry in China are presented. The technology of molding, melting and casting of titanium alloy, casting quality control are introduced. The existing problems and development trend in titanium alloy casting technology are also discussed.

  11. Stainless Steel to Titanium Bimetallic Transitions

    Energy Technology Data Exchange (ETDEWEB)

    Kaluzny, J. A. [Fermilab; Grimm, C. [Fermilab; Passarelli, D. [Fermilab

    2015-01-01

    In order to use stainless steel piping in an LCLS-II (Linac Coherent Light Source Upgrade) cryomodule, stainless steel to titanium bimetallic transitions are needed to connect the stainless steel piping to the titanium cavity helium vessel. Explosion bonded stainless steel to titanium transition pieces and bimetallic transition material samples have been tested. A sample transition tube was subjected to tests and x-ray examinations between tests. Samples of the bonded joint material were impact and tensile tested at room temperature as well as liquid helium temperature. The joint has been used successfully in horizontal tests of LCLS-II cavity helium vessels and is planned to be used in LCLS-II cryomodules. Results of material sample and transition tube tests will be presented.

  12. Titanium in fatigue critical military aircraft structure

    Energy Technology Data Exchange (ETDEWEB)

    Gillespie, F.

    1999-07-01

    This paper discusses the effect of fatigue requirements on titanium structure in military aircraft applications, specifically, fighter aircraft. The discussion covers how fatigue affects the design and analysis of detail parts, and how manufacturing processes affect the fatigue performance of titanium structure. Criteria for designing fighter aircraft have evolved from simple strength calculations to extremely complex computer generated analyses involving strength, durability, damage tolerance and fatigue. Fatigue life prediction is an important part of these analyses and dramatically affects the design and weight of fighter aircraft. Manufacturing processes affect fatigue performance both in a positive and negative manner. Designers must allow for the effect of these processes on titanium structure and consider the efficiency and economy of adding processes that increase fatigue life.

  13. Genotoxicity of titanium dioxide nanoparticles

    Directory of Open Access Journals (Sweden)

    Tao Chen

    2014-03-01

    Full Text Available Titanium dioxide nanoparticles (TiO2-NPs, <100 nm are increasingly being used in pharmaceuticals and cosmetics due to the unique properties derived from their small sizes. However, their large surface-area to mass ratio and high redox potential may negatively impact human health and the environment. TiO2-NPs can cause inflammation, pulmonary damage, fibrosis, and lung tumors and they are possibly carcinogenic to humans. Because cancer is a disease involving mutation, there are a large number of studies on the genotoxicity of TiO2-NPs. In this article, we review the results that have been reported in the literature, with a focus on data generated from the standard genotoxicity assays. The data include genotoxicity results from the Ames test, in vitro and in vivo Comet assay, in vitro and in vivo micronucleus assay, sister chromatid exchange assay, mammalian cell hypoxanthine-guanine phosphoribosyl transferase gene assay, the wing somatic mutation and recombination assay, and the mouse phosphatidylinositol glycan, class A gene assay. Inconsistent results have been found in these assays, with both positive and negative responses being reported. The in vitro systems for assessing the genotoxicity of TiO2-NPs have generated a greater number of positive results than the in vivo systems, and tests for DNA and chromosome damage have produced more positive results than the assays measuring gene mutation. Nearly all tests for measuring the mutagenicity of TiO2-NPs were negative. The current data indicate that the genotoxicity of TiO2-NPs is mediated mainly through the generation of oxidative stress in cells.

  14. Method for the production of strongly adhesive films on titanium and titanium alloys with a metallization process

    Science.gov (United States)

    Hahn, H. J.

    1986-01-01

    A process for the spray-application of a strongly adhesive, thick antifriction layer on titanium and titanium alloys is proposed. The titanium/titanium alloy component to be coated is first subjected to cleaning in a pickling bath with reducing additives and sand-blasting, then coated with an intermediate layer of nickel, after which the final layer is applied. The formation of TiNi at the interface ensures strong bonding of the antifriction layer.

  15. Titanium dioxide nanoparticles – Biological effects

    OpenAIRE

    Anna Maria Świdwińska-Gajewska; Sławomir Czerczak

    2014-01-01

    Titanium dioxide occurs as particles of various sizes. Particles of up to 100 nm, corresponding to nanoparticles, and in the size range of 0.1–3 mm are the most frequently used. Titanium dioxide in a bulk form is not classified as dangerous substance, nevertheless nanoparticles may cause adverse health effects. Inhalation exposure to nano-TiO2 causes pulmonary inflammation that may lead to fibrotic and proliferative changes in the lungs. Many studies confirm the genotoxic effect of TiO2, espe...

  16. Magnetically controlled recrystallization texture in titanium

    Energy Technology Data Exchange (ETDEWEB)

    Molodov, D.A. [Inst. fuer Metallkunde und Metallphysik, RWTH Aachen (Germany); Sheikh-Ali, A.D. [National High Magnetic Field Lab. and FAMU-FSU Coll. of Engineering, Tallahassee, FL (United States)

    2004-07-01

    The annealing of cold rolled (82%) titanium sheet at 750 C in a magnetic field of 19.4 Tesla results in a distinct difference between texture peaks when the sample is tilted by +30 or -30 to the field direction around the rolling direction, i.e. c (<0001>)-axis of grains corresponding to one texture component is aligned normal to the field direction. This result is attributed to grain growth affected by an additional driving force arising in a magnetic field by the anisotropy of the magnetic susceptibility of titanium. (orig.)

  17. Powder injection molding of pure titanium

    Institute of Scientific and Technical Information of China (English)

    GUO Shibo; DUAN Bohua; HE Xinbo; QU Xuanhui

    2009-01-01

    An improved wax-based binder was developed for powder injection molding of pure titanium. A critical powder loading of 69 vol.% and a pseudo-plastic flow behavior were obtained by the feedstock based on the binder. The injection molding, debinding, and sintering process were studied. An ideal control of carbon and oxygen contents was achieved by thermal debinding in vacuum atmosphere (10-3 Pa). The mechanical properties of as-sintered specimens were less than those of titanium made by the conventional press-sintering process. Good shape retention and ±0.04 mm dimension deviation were achieved.

  18. Titanium nanostructural surface processing for improved biocompatibility

    International Nuclear Information System (INIS)

    X-ray photoelectron spectroscopy, grazing incident x-ray diffraction, transmission electron microscopy, and scanning electron microscopy were conducted to evaluate the effect of titanium hydride on the formation of nanoporous TiO2 on Ti during anodization. Nano-titanium-hydride was formed cathodically before anodizing and served as a sacrificial nanoprecipitate during anodization. Surface oxidation occurred and a multinanoporous structure formed after cathodic pretreatments followed by anodization treatment. The sacrificial nanoprecipitate is directly dissolved and the Ti transformed to nanoporous TiO2 by anodization. The formation of sacrificial nanoprecipitates by cathodic pretreatment and of the multinanostructure by anodization is believed to improve biocompatibility, thereby promoting osseointegration

  19. Local heating with titanium nitride nanoparticles

    DEFF Research Database (Denmark)

    Guler, Urcan; Ndukaife, Justus C.; Naik, Gururaj V.;

    2013-01-01

    We investigate the feasibility of titanium nitride (TiN) nanoparticles as local heat sources in the near infrared region, focusing on biological window. Experiments and simulations provide promising results for TiN, which is known to be bio-compatible.......We investigate the feasibility of titanium nitride (TiN) nanoparticles as local heat sources in the near infrared region, focusing on biological window. Experiments and simulations provide promising results for TiN, which is known to be bio-compatible....

  20. Hydrogen storage with titanium-functionalized graphene

    CERN Document Server

    Mashoff, Torge; Tanabe, Shinichi; Hibino, Hiroki; Beltram, Fabio; Heun, Stefan

    2013-01-01

    We report on hydrogen adsorption and desorption on titanium-covered graphene in order to test theoretical proposals to use of graphene functionalized with metal atoms for hydrogen storage. At room temperature titanium islands grow with an average diameter of about 10 nm. Samples were then loaded with hydrogen, and its desorption kinetics was studied by thermal desorption spectroscopy. We observe the desorption of hydrogen in the temperature range between 400K and 700 K. Our results demonstrate the stability of hydrogen binding at room temperature and show that hydrogen desorbs at moderate temperatures in line with what required for practical hydrogen-storage applications.

  1. Creating mobile apps with Appcelerator Titanium

    CERN Document Server

    Brousseau, Christian

    2013-01-01

    Creating Mobile Apps with Appcelerator Titanium provides a hands-on approach and working examples on creating apps and games as well as embedding them onto a social networking website. Developers can then move on from there to develop their own applications based on the ones they have developed throughout the course of this book.""Creating Mobile Apps with Appcelerator Titanium"" is for developers who have experience with modern languages and development environments. Also, if you are familiar with the concepts of Object-oriented Programming (OOP), reusable components, AJAX closures, and so on

  2. Rapidly solidified titanium alloys by melt overflow

    Science.gov (United States)

    Gaspar, Thomas A.; Bruce, Thomas J., Jr.; Hackman, Lloyd E.; Brasmer, Susan E.; Dantzig, Jonathan A.; Baeslack, William A., III

    1989-01-01

    A pilot plant scale furnace was designed and constructed for casting titanium alloy strips. The furnace combines plasma arc skull melting techniques with melt overflow rapid solidification technology. A mathematical model of the melting and casting process was developed. The furnace cast strip of a suitable length and width for use with honeycomb structures. Titanium alloys Ti-6Al-4V and Ti-14Al-21 Nb were successfully cast into strips. The strips were evaluated by optical metallography, microhardness measurements, chemical analysis, and cold rolling.

  3. On Silicides in High Temperature Titanium Alloys

    OpenAIRE

    Ramachandra, C.; Vakil Singh; P. Rama Rao

    1986-01-01

    High temperature titanium alloys like IMI 685 contain small amounts of silicon (~ 0.25 wt. per cent) to improve creep resistance. Different types of silicides, namely Ti5Si3 (TiZr)5Si3(S1) and (TiZr)6 Si3 (S2), have been observed to precipitate in various silicon-bearing titanium alloys depending upon their composition and heat treatment. The precipitation of silicides, their orientation relationship with the matrix in different alloys, and the beneficial influence of thermo-mechanical treatm...

  4. Structure and properties of Titanium for dental implants

    Directory of Open Access Journals (Sweden)

    M. Greger

    2009-10-01

    Full Text Available This paper describes manufacture of nano-structural titanium, its structure and properties. Nano-titanium has higher specific strength properties than ordinary (coarse-grained titanium. Nano-titanium was produced by the equal-channel angular pressing (ETAP process. The research it self was focused on physical base of strengthening and softening processes and developments occurring at the grain boundaries during the ECAP process at half-hot temperature. Strength of nano-titanium varies around 960 MPa, grain size around 300 nm.

  5. The formation of titanium dioxide crystallite nanoparticles during activation of PAN nanofibers containing titanium isopropoxide

    Energy Technology Data Exchange (ETDEWEB)

    Mehrpouya, Fahimeh; Tavanai, Hossein, E-mail: tavanai@cc.iut.ac.ir; Morshed, Mohammad [Isfahan University of Technology, Department of Textile Engineering, Center of Excellence in Applied Nanotechnology (Iran, Islamic Republic of); Ghiaci, Mehran [Isfahan University of Technology, Department of Chemistry (Iran, Islamic Republic of)

    2012-08-15

    Activated carbon (AC) can act as an important carrier for TiO{sub 2} nanoparticles. TiO{sub 2} nanoparticle can be fabricated by the hydrolysis and condensation of titanium alkoxides like titanium isopropoxide. This study showed that the formation of titanium dioxide crystallite nanoparticle during activation of PAN nanofibers containing titanium isopropoxide leads to the formation of mainly anatase crystal TiO{sub 2} nanoparticle in AC nanofibers, with a good dispersion in both the longitude and cross section of nanofibers. The TiO{sub 2} crystallite size lies in the range of 7.3-11.3 nm. The dispersion of TiO{sub 2} nanoparticles in the matrix of AC nanofibers is far superior to the direct mixing of TiO{sub 2} nanoparticles in the original electrospinning solution.

  6. Structure of molten titanium dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Alderman, O. L. G.; Skinner, L. B.; Benmore, C. J.; Tamalonis, A.; Weber, J. K. R.

    2014-09-18

    The x-ray structure factor of molten TiO2 has been measured for the first time, enabled by the use of aerodynamic levitation and laser beam heating, to a temperature of T = 2250(30) K. Ti-O coordination number in the melt is close to nTiO = 5.0(2), with modal Ti-O bond length rTiO = 1.881(5) Å, both values being significantly smaller than for the high temperature stable Rutile crystal structure (nTiO = 6.0, rTiO = 1.959 Å). The structural differences between melt and crystal are qualitatively similar to those for alumina, which is rationalized in terms of the similar field strengths of Ti4+ and Al3+. The diffraction data are used to generate physically and chemically reasonable structural models, which are then compared to the predictions based on various classical molecular dynamics (MD) potentials. New interatomic potentials, suitable for modelling molten TiO2, are introduced, given the inability of existing MD models to reproduce the diffraction data. These new potentials have the additional great advantage of being able to predict the density and thermal expansion of the melt, as well as solid amorphous TiO2, in agreement with published results. This is of critical importance given the strong correlation between density and structural parameters such as nTiO. The large thermal expansion of the melt is associated with weakly temperature dependent structural changes, whereby simulations show that nTiO = 5.85(2) – (3.0(1) x 10-4 )T (K, 2.75 Å cut-off). The TiO2 liquid is structurally analogous to the geophysically relevant high pressure liquid silica system at around 27 GPa. We argue that the predominance of 5-fold polyhedra in the melt implies the existence of as yet undiscovered TiO2 polymorphs, based on lowerthan-octahedral coordination numbers, which are likely to be metastable under ambient conditions. Given the industrial importance of titanium oxides, experimental and computational searches for such polymorphs are well warranted.

  7. Structure of molten titanium dioxide

    Science.gov (United States)

    Alderman, O. L. G.; Skinner, L. B.; Benmore, C. J.; Tamalonis, A.; Weber, J. K. R.

    2014-09-01

    The x-ray structure factor of molten TiO2 has been measured, enabled by the use of aerodynamic levitation and laser beam heating, to a temperature of T=2250(30)K. The Ti-O coordination number in the melt is close to nTiO=5.0(2), with modal Ti-O bond length rTiO=1.881(5)Å, both values being significantly smaller than for the high temperature stable rutile crystal structure (nTiO=6.0,rTiO=1.959Å). The structural differences between melt and crystal are qualitatively similar to those for alumina, which is rationalized in terms of the similar field strengths of Ti4+ and Al3+. The diffraction data are used to generate physically and chemically reasonable structural models, which are then compared to the predictions based on various classical molecular dynamics (MD) potentials. Interatomic potentials, suitable for modeling molten TiO2, are introduced, given the inability of existing MD models to reproduce the diffraction data. These potentials have the additional advantage of being able to predict the density and thermal expansion of the melt, as well as solid amorphous TiO2, in agreement with published results. This is of critical importance given the strong correlation between density and structural parameters such as nTiO. The large thermal expansion of the melt is associated with weakly temperature dependent structural changes, whereby simulations show that nTiO=5.85(2)-[3.0(1)×10-4]T(K ,2.75Åcutoff). The TiO2 liquid is structurally analogous to the geophysically relevant high pressure liquid silica system at around 27 GPa. We argue that the predominance of fivefold polyhedra in the melt implies the existence of as-yet-undiscovered TiO2 polymorphs, based on lower-than-octahedral coordination numbers, which are likely to be metastable under ambient conditions. Given the industrial importance of titanium oxides, experimental and computational searches for such polymorphs are well warranted.

  8. Comparative analysis of weld properties of titanium-niobium, titanium molybdenum and stainless steel archwires

    OpenAIRE

    Vinod Pattabiraman; V Shashikala Kumari; Sarala Upadhya; Nausheer Ahmed

    2014-01-01

    Objective: Ability to achieve sound weld joints is a desirable characteristic for orthodontic archwires. Titanium molybdenum alloy (TMA) has been the only truly weldable orthodontic archwire alloy until now. Titanium-niobium (Ti-Nb) alloy archwires exhibit similar mechanical properties as TMA. Whether sound weld joints can be produced in these wires has not been evaluated thus far. In this study Ti-Nb alloy archwires were compared with TMA and stainless steel (SS) for weld quality, with SS wi...

  9. Titanium Oxide: A Bioactive Factor in Osteoblast Differentiation

    Directory of Open Access Journals (Sweden)

    P. Santiago-Medina

    2015-01-01

    Full Text Available Titanium and titanium alloys are currently accepted as the gold standard in dental applications. Their excellent biocompatibility has been attributed to the inert titanium surface through the formation of a thin native oxide which has been correlated to the excellent corrosion resistance of this material in body fluids. Whether this titanium oxide layer is essential to the outstanding biocompatibility of titanium surfaces in orthopedic biomaterial applications is still a moot point. To study this critical aspect further, human fetal osteoblasts were cultured on thermally oxidized and microarc oxidized (MAO surfaces and cell differentiation, a key indicator in bone tissue growth, was quantified by measuring the expression of alkaline phosphatase (ALP using a commercial assay kit. Cell attachment was similar on all the oxidized surfaces although ALP expression was highest on the oxidized titanium alloy surfaces. Untreated titanium alloy surfaces showed a distinctly lower degree of ALP activity. This indicates that titanium oxide clearly upregulates ALP expression in human fetal osteoblasts and may be a key bioactive factor that causes the excellent biocompatibility of titanium alloys. This result may make it imperative to incorporate titanium oxide in all hard tissue applications involving titanium and other alloys.

  10. Titanium Metal Powder Production by the Plasma Quench Process

    Energy Technology Data Exchange (ETDEWEB)

    R. A. Cordes; A. Donaldson

    2000-09-01

    The goals of this project included the scale-up of the titanium hydride production process to a production rate of 50 kg/hr at a purity level of 99+%. This goal was to be achieved by incrementally increasing the production capability of a series of reactor systems. This methodic approach was designed to allow Idaho Titanium Technologies to systematically address the engineering issues associated with plasma system performance, and powder collection system design and performance. With quality powder available, actual fabrication with the titanium hydride was to be pursued. Finally, with a successful titanium production system in place, the production of titanium aluminide was to be pursued by the simultaneously injection of titanium and aluminum precursors into the reactor system. Some significant accomplishments of the project are: A unique and revolutionary torch/reactor capable of withstanding temperatures up to 5000 C with high thermal efficiency has been operated. The dissociation of titanium tetrachloride into titanium powder and HC1 has been demonstrated, and a one-megawatt reactor potentially capable of producing 100 pounds per hour has been built, but not yet operated at the powder level. The removal of residual subchlorides and adsorbed HC1 and the sintering of powder to form solid bodies have been demonstrated. The production system has been operated at production rates up to 40 pounds per hour. Subsequent to the end of the project, Idaho Titanium Technologies demonstrated that titanium hydride powder can indeed be sintered into solid titanium metal at 1500 C without sintering aids.

  11. Formation and composition of titanium oxinitride nanocrystals synthesized via nitridizing titanium oxide for nonvolatile memory applications

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Li-Wei; Chang, Chun-Yen [Department of Electronics Engineering, National Chiao Tung University, Hsinchu, 300, Taiwan (China); Institute of Electronics, National Chiao Tung University, Hsinchu, 300, Taiwan (China); Chang, Ting-Chang, E-mail: tcchang@mail.phys.nsysu.edu.tw [Department of Physics, National Sun Yat-Sen University, Kaohsiung, 804, Taiwan (China); Center for Nanoscience and Nanotechnology, National Sun Yat-Sen University, Kaohsiung, 804, Taiwan (China); Tu, Chun-Hao; Wang, Pai-Syuan [Department of Electronics Engineering, National Chiao Tung University, Hsinchu, 300, Taiwan (China); Institute of Electronics, National Chiao Tung University, Hsinchu, 300, Taiwan (China); Lin, Chao-Cheng [Green Energy and Environment Research Laboratories, Industrial Technology Research Institute, Hsinchu, 310, Taiwan (China); Chen, Min-Chen [Department of Physics, National Sun Yat-Sen University, Kaohsiung, 804, Taiwan (China); Huang, Hui-Chun; Gan, Der-Shin; Ho, New-Jin [Institute of Materials Science and Engineering, National Sun Yat-Sen University, Kaohsiung, 804, Taiwan (China); Chen, Shih-Ching [Department of Physics, National Sun Yat-Sen University, Kaohsiung, 804, Taiwan (China); Chen, Shih-Cheng [Department of Electrical Engineering, National Tsing Hua University, Hsinchu, 310, Taiwan, ROC (China); Institute of Electronic Engineering, National Tsing Hua University, Hsinchu, 310, Taiwan (China)

    2011-09-01

    Formation and composition analyses of titanium oxinitride nanocrystals (NCs) fabricated via treating a magnetron co-sputtered thin film of titanium and silicon dioxide with a rapid thermal annealing in nitrogen ambient were demonstrated for nonvolatile memory applications. Phase separation characteristics with different annealing conditions were examined by transmission electron microscopy and chemical bonding characteristics were confirmed by X-ray photon emission spectra. It was observed that a blanket layer composed mainly of titanium oxide was still present as annealing temperature was increased to 700 deg. C, associated with the thermodynamically stable phase of titanium oxide. Furthermore, a higher thermal treatment of 900 deg. C induced formation of a well-separated NC structure and caused simultaneously partial nitridation of the titanium oxide, thereby forming titanium oxinitride NCs. A significant capacitance-voltage hysteresis in threshold voltage shift at 1 V was easily achieved under a small sweeping voltage range of + 2 V/-2 V, and a memory window retention of 2.2 V was obtained after 10{sup 7} s by extrapolation under a 1 s initial-program/erase condition of + 5 V/-5 V, respectively.

  12. Laser repair hardfacing of titanium alloy turbine

    Directory of Open Access Journals (Sweden)

    A. Klimpel

    2011-12-01

    Full Text Available Purpose: of this paper: work out repair technology of worn abutments of aircraft jet engine blades forged of titanium alloy WT3-1.Design/methodology/approach: The study were based on the analysis of laser HPDL powder surfacing of titanium alloy plates using wide range chemical composition consumables of titanium alloys and mixtures of pure titanium and spherical powder of WC indicated that very hard and highest quality deposits are provided by powder mixture of 40-50%Ti+60-50%WC.Findings: It was found that it is possible to achieve high quality deposits, free of any defects. HPDL technology can be used to repair worn turbine blade.Research limitations/implications: It was found that it is possible to repair the worn areas abutments of blades of zero compression stage of aircraft engine turbine by HPDL laser surfacing with using composite powder mixture of 50%Ti+50%WC as an additional material.Practical implications: The technology can be applied for repair worn abutments of aircraft jet engine blades.Originality/value: Repairing worn abutments of aircraft jet engine blades.

  13. Study on Crystallization of Titanium Silicalite (Ⅰ)

    Institute of Scientific and Technical Information of China (English)

    Lin Min; Zhu Bin; Shu Xingtian; Wang Xieqing

    2008-01-01

    In order to investigate the rules on preparation of titanium silicalite (TS-1) the 1H→13C CP/MAS NMR spectrometers were applied to track the function of template TPAOH in the process of crystal lization of titanium silicalite.The research results revealed that at the initial stage of crystallization the TPA+ ions acting as the template could predominantly absorb the polymers of negatively charged silicatitania sol and the interactions between silica sol and titania sol could gradually lead to the formation of tiny crystal nuclei that could slowly grow up to form molecular sieves.Upon investigating the course of crystallization of titanium silicalite the 1H→13C CP/MAS NMR spectrometers were applied to effectively enhance the resolution of 29Si signals in the titanium silicalite.Study results have shown that during the formation of tiny crystal nuclei upon interaction between titania sol and silica sol the influence of titania sol on the silica sol was insignificant.However,when tiny crystal nuclei broke out into molecular sieves the titania sol could enter the zeolite framework that could apparently impose an enhanced effect on the silica sol.

  14. Characterization of Micro-arc Oxidized Titanium

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    The observation of the sparkling discharges during the micro-arc oxidation process in KOH aqueous electrolyte was achieved. The change of surface morphology was progressively observed and a plausible pore formation mechanism is proposed. Cell proliferation and ALP activity of micro-arc oxidized titanium was evaluated by human body derived osteoblasts and slightly better than those of blasted surface.

  15. Lactobacillus assisted synthesis of titanium nanoparticles

    Science.gov (United States)

    Prasad, K.; Jha, Anal K.; Kulkarni, A. R.

    2007-05-01

    An eco-friendly lactobacillus sp. (microbe) assisted synthesis of titanium nanoparticles is reported. The synthesis is performed at room temperature. X-ray and transmission electron microscopy analyses are performed to ascertain the formation of Ti nanoparticles. Individual nanoparticles as well as a number of aggregates almost spherical in shape having a size of 40 60 nm are found.

  16. Titanium surface hydrophilicity enhances platelet activation.

    Science.gov (United States)

    Alfarsi, Mohammed A; Hamlet, Stephen M; Ivanovski, Saso

    2014-01-01

    Titanium implant surface modification is a key strategy used to enhance osseointegration. Platelets are the first cells that interact with the implant surface whereupon they release a wide array of proteins that influence the subsequent healing process. This study therefore investigated the effect of titanium surface modification on the attachment and activation of human platelets. The surface characteristics of three titanium surfaces: smooth (SMO), micro-rough (SLA) and hydrophilic micro-rough (SLActive) and the subsequent attachment and activation of platelets following exposure to these surfaces were determined. The SLActive surface showed the presence of significant nanoscale topographical features. While attached platelets appeared to be morphologically similar, significantly fewer platelets attached to the SLActive surface compared to both the SMO and SLA surfaces. The SLActive surface however induced the release of the higher levels of chemokines β-thromboglobulin and platelet factor 4 from platelets. This study shows that titanium surface topography and chemistry have a significant effect on platelet activation and chemokine release.

  17. Titanium tungsten coatings for bioelectrochemical applications

    DEFF Research Database (Denmark)

    Wierzbicki, Rafal; Amato, Letizia; Łopacińska, J.;

    2011-01-01

    This paper presents an assessment of titanium tungsten (TiW) coatings and their applicability as components of biosensing systems. The focus is put on using TiW as an electromechanical interface layer between carbon nanotube (CNT) forests and silicon nanograss (SiNG) cell scaffolds. Cytotoxicity...

  18. Biocorrosion study of titanium-cobalt alloys.

    Science.gov (United States)

    Chern Lin, J H; Lo, S J; Ju, C P

    1995-05-01

    The present work provides experimental results of corrosion behaviour in Hank's physiological solution and some other properties of in-house fabricated titanium-cobalt alloys with cobalt ranging from 25-30% in weight. X-ray diffraction (XRD) shows that, in water-quenched (WQ) alloys, beta-titanium is largely retained, whereas in furnace-cooled (FC) alloys, little beta-titanium is found. Hardness of the alloys increases with increasing cobalt content, ranging from 455 VHN for WQ Ti-25 wt% Co to 525 VHN for WQ Ti-30 wt% Co. Differential thermal analysis (DTA) indicates that melting temperatures of the alloys are lower than that of pure titanium by about 600 degrees C. Potentiodynamic polarization results show that all measured break-down potentials in Hank's solution at 37 degrees C are higher than 800 mV. The breakdown potential for the FC Ti-25 Wt% Co alloy is even as high as nearly 1200 mV.

  19. Bioactive borate glass coatings for titanium alloys.

    Science.gov (United States)

    Peddi, Laxmikanth; Brow, Richard K; Brown, Roger F

    2008-09-01

    Bioactive borate glass coatings have been developed for titanium and titanium alloys. Glasses from the Na(2)O-CaO-B(2)O(3) system, modified by additions of SiO(2), Al(2)O(3), and P(2)O(5), were characterized and compositions with thermal expansion matches to titanium were identified. Infrared and X-ray diffraction analyses indicate that a hydroxyapatite surface layer forms on the borate glasses after exposure to a simulated body fluid for 2 weeks at 37 degrees C; similar layers form on 45S5 Bioglass((R)) exposed to the same conditions. Assays with MC3T3-E1 pre-osteoblastic cells show the borate glasses exhibit in vitro biocompatibility similar to that of the 45S5 Bioglass((R)). An enameling technique was developed to form adherent borate glass coatings on Ti6Al4V alloy, with adhesive strengths of 36 +/- 2 MPa on polished substrates. The results show these new borate glasses to be promising candidates for forming bioactive coatings on titanium substrates.

  20. Bioactive macroporous titanium implants highly interconnected.

    Science.gov (United States)

    Caparrós, Cristina; Ortiz-Hernandez, Mónica; Molmeneu, Meritxell; Punset, Miguel; Calero, José Antonio; Aparicio, Conrado; Fernández-Fairén, Mariano; Perez, Román; Gil, Francisco Javier

    2016-10-01

    Intervertebral implants should be designed with low load requirements, high friction coefficient and low elastic modulus in order to avoid the stress shielding effect on bone. Furthermore, the presence of a highly interconnected porous structure allows stimulating bone in-growth and enhancing implant-bone fixation. The aim of this study was to obtain bioactive porous titanium implants with highly interconnected pores with a total porosity of approximately 57 %. Porous Titanium implants were produced by powder sintering route using the space holder technique with a binder phase and were then evaluated in an in vivo study. The size of the interconnection diameter between the macropores was about 210 μm in order to guarantee bone in-growth through osteblastic cell penetration. Surface roughness and mechanical properties were analyzed. Stiffness was reduced as a result of the powder sintering technique which allowed the formation of a porous network. Compression and fatigue tests exhibited suitable properties in order to guarantee a proper compromise between mechanical properties and pore interconnectivity. Bioactivity treatment effect in novel sintered porous titanium materials was studied by thermo-chemical treatments and were compared with the same material that had undergone different bioactive treatments. Bioactive thermo-chemical treatment was confirmed by the presence of sodium titanates on the surface of the implants as well as inside the porous network. Raman spectroscopy results suggested that the identified titanate structures would enhance in vivo apatite formation by promoting ion exchange for the apatite formation process. In vivo results demonstrated that the bioactive titanium achieved over 75 % tissue colonization compared to the 40 % value for the untreated titanium. PMID:27582071

  1. Machined Titanium Heat-Pipe Wick Structure

    Science.gov (United States)

    Rosenfeld, John H.; Minnerly, Kenneth G.; Gernert, Nelson J.

    2009-01-01

    Wick structures fabricated by machining of titanium porous material are essential components of lightweight titanium/ water heat pipes of a type now being developed for operation at temperatures up to 530 K in high-radiation environments. In the fabrication of some prior heat pipes, wicks have been made by extruding axial grooves into aluminum unfortunately, titanium cannot be extruded. In the fabrication of some other prior heat pipes, wicks have been made by in-situ sintering of metal powders shaped by the use of forming mandrels that are subsequently removed, but in the specific application that gave rise to the present fabrication method, the required dimensions and shapes of the heat-pipe structures would make it very difficult if not impossible to remove the mandrels due to the length and the small diameter. In the present method, a wick is made from one or more sections that are fabricated separately and assembled outside the tube that constitutes the outer heat pipe wall. The starting wick material is a slab of porous titanium material. This material is machined in its original flat configuration to form axial grooves. In addition, interlocking features are machined at the mating ends of short wick sections that are to be assembled to make a full-length continuous wick structure. Once the sections have been thus assembled, the resulting full-length flat wick structure is rolled into a cylindrical shape and inserted in the heatpipe tube (see figure). This wick-structure fabrication method is not limited to titanium/water heat pipes: It could be extended to other heat pipe materials and working fluids in which the wicks could be made from materials that could be pre-formed into porous slabs.

  2. Rapid prototyped porous nickel–titanium scaffolds as bone substitutes

    Directory of Open Access Journals (Sweden)

    Waldemar Hoffmann

    2014-06-01

    Full Text Available While calcium phosphate–based ceramics are currently the most widely used materials in bone repair, they generally lack tensile strength for initial load bearing. Bulk titanium is the gold standard of metallic implant materials, but does not match the mechanical properties of the surrounding bone, potentially leading to problems of fixation and bone resorption. As an alternative, nickel–titanium alloys possess a unique combination of mechanical properties including a relatively low elastic modulus, pseudoelasticity, and high damping capacity, matching the properties of bone better than any other metallic material. With the ultimate goal of fabricating porous implants for spinal, orthopedic and dental applications, nickel–titanium substrates were fabricated by means of selective laser melting. The response of human mesenchymal stromal cells to the nickel–titanium substrates was compared to mesenchymal stromal cells cultured on clinically used titanium. Selective laser melted titanium as well as surface-treated nickel–titanium and titanium served as controls. Mesenchymal stromal cells had similar proliferation rates when cultured on selective laser melted nickel–titanium, clinically used titanium, or controls. Osteogenic differentiation was similar for mesenchymal stromal cells cultured on the selected materials, as indicated by similar gene expression levels of bone sialoprotein and osteocalcin. Mesenchymal stromal cells seeded and cultured on porous three-dimensional selective laser melted nickel–titanium scaffolds homogeneously colonized the scaffold, and following osteogenic induction, filled the scaffold’s pore volume with extracellular matrix. The combination of bone-related mechanical properties of selective laser melted nickel–titanium with its cytocompatibility and support of osteogenic differentiation of mesenchymal stromal cells highlights its potential as a superior bone substitute as compared to clinically used

  3. Rapid prototyped porous nickel-titanium scaffolds as bone substitutes.

    Science.gov (United States)

    Hoffmann, Waldemar; Bormann, Therese; Rossi, Antonella; Müller, Bert; Schumacher, Ralf; Martin, Ivan; de Wild, Michael; Wendt, David

    2014-01-01

    While calcium phosphate-based ceramics are currently the most widely used materials in bone repair, they generally lack tensile strength for initial load bearing. Bulk titanium is the gold standard of metallic implant materials, but does not match the mechanical properties of the surrounding bone, potentially leading to problems of fixation and bone resorption. As an alternative, nickel-titanium alloys possess a unique combination of mechanical properties including a relatively low elastic modulus, pseudoelasticity, and high damping capacity, matching the properties of bone better than any other metallic material. With the ultimate goal of fabricating porous implants for spinal, orthopedic and dental applications, nickel-titanium substrates were fabricated by means of selective laser melting. The response of human mesenchymal stromal cells to the nickel-titanium substrates was compared to mesenchymal stromal cells cultured on clinically used titanium. Selective laser melted titanium as well as surface-treated nickel-titanium and titanium served as controls. Mesenchymal stromal cells had similar proliferation rates when cultured on selective laser melted nickel-titanium, clinically used titanium, or controls. Osteogenic differentiation was similar for mesenchymal stromal cells cultured on the selected materials, as indicated by similar gene expression levels of bone sialoprotein and osteocalcin. Mesenchymal stromal cells seeded and cultured on porous three-dimensional selective laser melted nickel-titanium scaffolds homogeneously colonized the scaffold, and following osteogenic induction, filled the scaffold's pore volume with extracellular matrix. The combination of bone-related mechanical properties of selective laser melted nickel-titanium with its cytocompatibility and support of osteogenic differentiation of mesenchymal stromal cells highlights its potential as a superior bone substitute as compared to clinically used titanium.

  4. [Study on biocompatibility of titanium alloys].

    Science.gov (United States)

    Kodama, T

    1989-06-01

    The biocompatibility of two different titanium alloys, Ti-6Al-4V ELI and Ti-5Al-2, 5Fe, and pure titanium were evaluated. The results were as follows: 1) Titanium alloys were implanted into the dorsal subcutaneous tissues of the Hartley guinea-pig for 12 weeks, immersed in calf serum or in Ringer's solution for 8 weeks. The surface changes of the titanium alloys were observed by SEM and the chemical composition was analyzed by XMA. No evident surface changes were found. 2) Three hundred mg, 200 mg and 100 mg of the powders of the tested materials were immersed in 2ml of Eagle's MEM, incubated for 1-7 days, 8-21 days and 22-70 days at 37 C degrees. The amount of metallic elements dissolved in the solutions was measured by ICP and AAS. The detected corrosion rates of V and Al contained in the solution, in which Ti-6Al-4V ELI 100 mg was immersed for 1-7 days, were 194.3 +/- 17.6 and 73.0 +/- 28, 1 pg/mg alloy/day, respectively. V was released more than Al. The amount of Ti was below the detectable limit. The solution Ti-5Al-2.5 Fe 100 mg immersed for 1-7 days contained 31.9 +/- 34.4 pg/mg alloy/day Fe and 25.7 +/- 6.3 pg/mg alloy/day Al. Only in the solution 300 mg immersed for 1-7 days was Ti detected at 1.4 pg/mg alloy/day. 3) By the bacterial mutation assay of Salmonella typhimurium TA 98, Salmonella typhimurium TA 100 and Escherichia coli WP2 uvrA, the solutions, in which the tested materials were immersed, were not found to be mutagenic. 4) By the UDS assay, the grain counts on autoradiography with the solutions, in which the tested materials were immersed, were not greater than the negative control. The results suggest an excellent corrosion resistance of the titanium alloys. Mutagenicity was negative by these mutation assays, indicating that the tested alloys and pure titanium are safe for humans and animals.

  5. Highly porous nickel@carbon sponge as a novel type of three-dimensional anode with low cost for high catalytic performance of urea electro-oxidation in alkaline medium

    Science.gov (United States)

    Ye, Ke; Zhang, Dongming; Guo, Fen; Cheng, Kui; Wang, Guiling; Cao, Dianxue

    2015-06-01

    Highly porous nickel@carbon sponge electrode with low cost is synthesized via a facile sponge carbonization method coupled with a direct electrodeposition of Ni. The obtained electrodes are characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). The catalytic performances of urea electro-oxidation in alkaline medium are investigated by cyclic voltammetry (CV) and chronoamperometry (CA). The Ni@carbon sponge electrode exhibits three-dimensional open network structures with a large surface area. Remarkably, the Ni@carbon sponge electrode shows much higher electrocatalytic activity and lower onset oxidation potential towards urea electro-oxidation compared to a Ni/Ti flat electrode synthesized by the same procedure. The Ni@carbon sponge electrode achieves an onset oxidation potential of 0.24 V (vs. Ag/AgCl) and a peak current density of 290 mA cm-2 in 5 mol L-1 NaOH and 0.10 mol L-1 urea solutions accompanied with a desirable stability. The impressive electrocatalytic activity is largely attributed to the high intrinsic electronic conductivity, superior porous network structures and rich surface Ni active species, which can largely boost the interfacial electroactive sites and charge transfer rates for urea electro-oxidation in alkaline medium, indicating promising applications in fuel cells.

  6. Characterization of Titanium-Containing Compounds in Gray Iron

    Institute of Scientific and Technical Information of China (English)

    ZENG Daxin; ZHANG Yuanhao; LIU Jianyong; HE Hanjun; HONG Xiaoxian

    2008-01-01

    Titanium produces different compounds in gray iron. In order to determine their characteristics, a scanning electron microscope, an energy dispersive X-ray spectroscopy, and an optical microscopy were used to analyze the morphology, distribution, and composition of titanium-containing compounds in metal-lographic specimens and machined surfaces in four gray irons. The results show that the titanium-containing compounds in the gray irons are complex compounds containing V, Nb, Mn, S, and other metals, depending on the concentration of these elements in the iron. The number of titanium-containing compounds increases with increasing Ti content in the gray iron. Most of the titanium-containing compounds are located in the peariite matrix, with some in the steadite and carbides. The results suggest that titanium-containing com-pounds reduce tool lifetime.

  7. Grafting modification on the surface of titanium dioxide by polystyrene

    Institute of Scientific and Technical Information of China (English)

    Wei Wu; Shouci Lu; Jianfeng Chen; Lei Shao; CheeKing Tan

    2003-01-01

    Based on the technology of titanium dioxide grafting modification with polystyrene (PS), the modification mechanisms are studied and the polystyrene-grafting states on the surface of titanium dioxide have been set up. Under the synergistic actions of mechanical force, chemistry and heat, macromolecular free radicals of PS are created, at the same time, the O-O bonds of titanium dioxide are broken and the oxide free radicals produced, and the numbers of oxygen atom are increased and crystal lattice defects rich electrons are formed on the surface of titanium dioxide. The radical polymerization is the main reaction between PS and titanium dioxide and C-O bonds form in the process of modification. Multi-sites chemical adsorption also exists besides grafting between PS and titanium dioxide.

  8. Corrosion of titanium in supercritical water oxidation environments

    Institute of Scientific and Technical Information of China (English)

    卢建树; 毛志远; 张九渊; 马淳安; 毛信表; 李肖华

    2002-01-01

    Supercritical water oxidation (SCWO) can effectively destroy many kinds of civilian and military wastes. The high temperature and high pressure SCWO operation conditions generate very corrosive environment that many engineering materials fail to withstand. Preliminary test shows that titanium may be a promising material in most of SCWO conditions. Commercially pure titanium is tested in four kinds of SCWO environments. Phenol, sodium dodecyl-benzosulfonate, n-amine phenol, and chlorpyrifos were chosen as typical target pollutants. The results show that titanium is only superficially attacked in the first three SCWO environments while in chlorpyrifos SCWO medium titanium is corroded. The corrosion is temperature dependent, with heavier corrosion occurring at near critical temperature. X-ray diffraction analysis shows that the corrosion products consist of titanium oxy- phosphates and titanium oxide, in which Ti5O4(PO4)4 is the main phase.

  9. Welding of gamma titanium aluminide alloys

    Science.gov (United States)

    Smashey, Russell W. (Inventor); Kelly, Thomas J. (Inventor); Snyder, John H. (Inventor); Sheranko, Ronald L. (Inventor)

    1998-01-01

    An article made of a gamma titanium aluminide alloy is welded, as for example in the weld repair of surface cracks, by removing foreign matter from the area to be welded, first stress relieving the article, cooling the entire article to a welding temperature of from about 1000.degree. F. to about 1400.degree. F., welding a preselected region in an inert atmosphere at the welding temperature, and second stress relieving the article. Welding is preferably accomplished by striking an arc in the preselected region so as to locally melt the alloy in the preselected region, providing a filler metal having the same composition as the gamma titanium aluminide alloy of the article, and feeding the filler metal into the arc so that the filler metal is melted and fused with the article to form a weldment upon solidification.

  10. Environmental Studies on Titanium Aluminide Alloys

    Science.gov (United States)

    Brindley, William J.; Bartolotta, Paul A.; Smialek, James L.; Brady, Michael P.

    2005-01-01

    Titanium aluminides are attractive alternatives to superalloys in moderate temperature applications (600 to 850 C) by virtue of their high strength-to-density ratio (high specific strength). These alloys are also more ductile than competing intermetallic systems. However, most Ti-based alloys tend to degrade through interstitial embrittlement and rapid oxidation during exposure to elevated temperatures. Therefore, their environmental behavior must be thoroughly investigated before they can be developed further. The goals of titanium aluminide environmental studies at the NASA Lewis Research Center are twofold: characterize the degradation mechanisms for advanced structural alloys and determine what means are available to minimize degradation. The studies to date have covered the alpha 2 (Ti3Al), orthorhombic (Ti2AlNb), and gamma (TiAl) classes of alloys.

  11. Standard digital reference images for titanium castings

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 The digital reference images provided in the adjunct to this standard illustrate various types and degrees of discontinuities occurring in titanium castings. Use of this standard for the specification or grading of castings requires procurement of the adjunct digital reference images, which illustrate the discontinuity types and severity levels. They are intended to provide the following: 1.1.1 A guide enabling recognition of titanium casting discontinuities and their differentiation both as to type and degree through digital radiographic examination. 1.1.2 Example digital radiographic illustrations of discontinuities and a nomenclature for reference in acceptance standards, specifications and drawings. 1.2 The digital reference images consist of seventeen digital files each illustrating eight grades of increasing severity. The files illustrate seven common discontinuity types representing casting sections up to 1-in. (25.4-mm). 1.3 The reference radiographs were developed for casting sections up to 1...

  12. Biocorrosion study of titanium-nickel alloys.

    Science.gov (United States)

    Chern Lin, J H; Lo, S J; Ju, C P

    1996-02-01

    The present study provides results of the corrosion behaviour in Hank's physiological solution and some other properties of three Ti-Ni alloys with 18, 25 and 28.4 wt% Ni, respectively. Results indicate that alpha-titanium and Ti2Ni were the two major phases in all three Ti-Ni alloys. The relative amount of the Ti2Ni phase increased with additional Ni content. Hardness of the Ti-Ni alloys also increased with added nickel content, ranging from 310 to 390 VHN, similar to the hardness of enamel. Melting temperatures of the Ti-Ni alloys were all lower than that of pure titanium by least 600 degrees C. The three Ti-Ni alloys behaved almost identically when potentiodynamically polarized in Hank's solution at 37 degrees C. The critical anodic current densities of the alloys were nearly 30 microA/cm2 and the breakdown potentials were all above 1100 mV (SCE).

  13. Microstructure and Slip Character in Titanium Alloys

    Directory of Open Access Journals (Sweden)

    D. Banerjee

    1986-04-01

    Full Text Available Influence of microstructures in titanium alloys on the basic parameters of deformation behaviour such as slip character, slip length and slip intensity have been explored. Commercial titanium alloys contain the hexagonal close packed (alpha and body centred cubic (bita phases. Slip in these individual phases is shown to be dependent on the nature of alloying elements through their effect on phase stability as related to decomposition into ordered or w structures. When alpha and bita coexist, their relative crystallographic orientations, size, shape and volume fraction, control the nature of slip. For a given composition, structure may be manipulated through appropriate thermomechanical treatment to obtain the desired deformation behaviour and therefore fracture mode.

  14. Fatigue - corrosion of endoprosthesis titanium alloys.

    Science.gov (United States)

    Cornet, A; Muster, D; Jaeger, J H

    1979-01-01

    Commercial total hip prostheses often show certain metallurgical faults (porosities, coarse grains, growth dendrites, carbide networks). In order to investigate more accurately the role played by these different parameters in prostheses failure we performed a large number of systematic corrosion, fatigue and fatigue - corrosion tests on these materials and on commercial total hip prostheses. Ultimate strengthes seem to be reached for cast cobalt alloys, whereas titanium alloys, such as Ta 6 V, present very high fatigue limit under corrosion. Thus, rotative bending fatigue - corrosion tests in biological environment provide values about 50 DaN/mm2. This value, is nevertheless appreciably higher than those obtained with stellites and stainless steel. Titanium alloys, because of their mechanical performances, their weak Young's modulus (11000 DaN/mm2) and their relative lightness (4.5. g/cm3), which are associated with a good biocompatibility, seem very promising for permanent implants realisation.

  15. Dry face milling of titanium alloys

    Institute of Scientific and Technical Information of China (English)

    Ahmed Hassan; Zhenqiang Yao

    2004-01-01

    In machining titanium alloys, cutting tools generally wear out very rapidly because of the high cutting temperature resulted from the low thermal conductivity and density of the work material. In order to increase the tool life, it is necessary to suppress the cutting heat as much as possible by applying an abundant amount of coolant, but this will entail serious techno-environmental and biological problems. To study the performance and avoid these limitations, a PVD-coated insert was used to the dry face mill of (α +β) titanium alloys. As a result it was found that the inserts exhibit an excellent cutting performance at low cutting speeds and feed rates, and there is no significant difference in the dominant insert failure mode between the wet and dry cutting in discontinuous cutting.

  16. On Silicides in High Temperature Titanium Alloys

    Directory of Open Access Journals (Sweden)

    C. Ramachandra

    1986-04-01

    Full Text Available High temperature titanium alloys like IMI 685 contain small amounts of silicon (~ 0.25 wt. per cent to improve creep resistance. Different types of silicides, namely Ti5Si3 (TiZr5Si3(S1 and (TiZr6 Si3 (S2, have been observed to precipitate in various silicon-bearing titanium alloys depending upon their composition and heat treatment. The precipitation of silicides, their orientation relationship with the matrix in different alloys, and the beneficial influence of thermo-mechanical treatment on the distribution of silicides have been pointed out. The effect of silicides on mechanical properties and fracture of the commercial alloy IMI 685 is also indicated.

  17. Adsorption of octylamine on titanium dioxide

    International Nuclear Information System (INIS)

    Processes of adsorption and desorption of a model active substance (octylamine) on the surface of unmodified titanium dioxide (E 171) have been performed. The effects of concentration of octylamine and time of the process on the character of adsorption have been studied and the efficiency of the adsorption/desorption has been determined. The samples obtained have been studied by X-ray diffraction. The nitrogen adsorption/desorption isotherms, particle size distribution and absorption capacities of water, dibutyl phthalate and paraffin oil have been determined. The efficiency of octylamine adsorption on the surface of the titanium dioxide has been found positively correlated with the concentration of octylamine in the initial solution. The desorption of octylamine has decreased with increasing concentration of this compound adsorbed. For octylamine in low concentrations the physical adsorption has been found to dominate, which is desirable when using TiO2 in the production of pharmaceuticals.

  18. Fatigue Strength of Titanium Risers - Defect Sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Babalola, Olusegun Tunde

    2001-07-01

    This study is centred on assessment of the fatigue strength of titanium fusion welds for deep-water riser's applications. Deep-water risers are subjected to significant fatigue loading. Relevant fatigue data for titanium fusion welds are very scarce. Hence there is a need for fatigue data and life prediction models for such weldments. The study has covered three topics: Fatigue testing, Fractography and defect assessment, and Fracture Mechanics modelling of fatigue crack growth. Two series of welded grade of titanium consisting of 14 specimens in each series were fatigue tested under constant amplitude loading. Prior to fatigue testing, strain gauge measurements of some specimens was conducted to enable the definition of stress range in the fatigue assessment procedure. The results were compared with finite solid element analysis and related to fatigue stresses in a riser pipe wall. Distribution and geometry of internal and surface defects both in the as-welded and in the post-weld machined conditions were assessed using fractography. This served as a tool to determine the fatigue initiation point in the welds. Fracture mechanics was applied to model fatigue strength of titanium welds with initiation from weld defects. Two different stress intensity factor formulations for embedded eccentrically placed cracks were used for analysis of elliptical cracks with the major axis parallel and close to one of the free surfaces. The methods were combined to give a satisfactory model for crack growth analysis. The model analyses crack growth of elliptical and semi-elliptical cracks in two directions, with updating of the crack geometry. Fatigue strength assessment was conducted using two crack growth models, the Paris-Erdogan relation with no threshold and the Donahue et al. relation with an implied threshold. The model was validated against experimental data, with a discussion on the choice of crack growth model. (author)

  19. Mucin Secretion Induced by Titanium Dioxide Nanoparticles

    OpenAIRE

    Eric Y T Chen; Garnica, Maria; Wang, Yung-Chen; Chen, Chi-Shuo; Chin, Wei-chun

    2011-01-01

    Nanoparticle (NP) exposure has been closely associated with the exacerbation and pathophysiology of many respiratory diseases such as Chronic Obstructive Pulmonary Disease (COPD) and asthma. Mucus hypersecretion and accumulation in the airway are major clinical manifestations commonly found in these diseases. Among a broad spectrum of NPs, titanium dioxide (TiO2), one of the PM10 components, is widely utilized in the nanoindustry for manufacturing and processing of various commercial products...

  20. Thermal coatings for titanium-aluminum alloys

    Science.gov (United States)

    Cunnington, George R.; Clark, Ronald K.; Robinson, John C.

    1993-01-01

    Titanium aluminides and titanium alloys are candidate materials for use in hot structure and heat-shield components of hypersonic vehicles because of their good strength-to-weight characteristics at elevated temperature. However, in order to utilize their maximum temperature capability, they must be coated to resist oxidation and to have a high total remittance. Also, surface catalysis for recombination of dissociated species in the aerodynamic boundary layer must be minimized. Very thin chemical vapor deposition (CVD) coatings are attractive candidates for this application because of durability and very light weight. To demonstrate this concept, coatings of boron-silicon and aluminum-boron-silicon compositions were applied to the titanium-aluminides alpha2 (Ti-14Al-21Nb), super-alpha2 (Ti-14Al-23-Nb-2V), and gamma (Ti-33Al-6Nb-1Ta) and to the titanium alloy beta-21S (Ti-15Mo-3Al-3Nb-0.2Si). Coated specimens of each alloy were subjected to a set of simulated hypersonic vehicle environmental tests to determine their properties of oxidation resistance, surface catalysis, radiative emittance, and thermal shock resistance. Surface catalysis results should be viewed as relative performance only of the several coating-alloy combinations tested under the specific environmental conditions of the LaRC Hypersonic Materials Environmental Test System (HYMETS) arc-plasma-heated hypersonic wind tunnel. Tests were also conducted to evaluate the hydrogen transport properties of the coatings and any effects of the coating processing itself on fatigue life of the base alloys. Results are presented for three types of coatings, which are as follows: (1) a single layer boron silicon coating, (2) a single layer aluminum-boron-silicon coating, and (3) a multilayer coating consisting of an aluminum-boron-silicon sublayer with a boron-silicon outer layer.

  1. Titanium mesh cages (TMC) in spine surgery

    OpenAIRE

    Grob, Dieter; Daehn, Sylvia; Mannion, Anne F.

    2004-01-01

    The introduction of the titanium mesh cage (TMC) in spinal surgery has opened up a variety of applications that are realizable as a result of the versatility of the implant. Differing applications of TMCs in the whole spine are described in a series of 150 patients. Replacement and reinforcement of the anterior column represent the classic use of cylindrical TMCs. The TMC as a multisegmental concave support in kyphotic deformities and as a posterior interlaminar spacer or lamina replacement a...

  2. Surface characterization of titanium based dental implants

    International Nuclear Information System (INIS)

    Dental implantology uses metallic devices made of commercially pure titanium in order to replace lost teeth. Titanium presents favorable characteristics as bio material and modern implants are capable of integrate, witch is the union between bone and implant without fibrous tissue development. Three of the major Brazilian implant manufacturers were chosen to join the study. A foreign manufacturer participated as standard. The manufacturers had three specimens of each implant with two different surface finishing, as machined and porous, submitted to analysis. Surface chemical composition and implant morphology were analyzed by X-ray photoelectron spectroscopy (XP S), scanning electron microscopy (SEM) and microprobe. Implant surface is mainly composed of titanium, oxygen and carbon. Few contaminants commonly present on implant surface were found on samples. Superficial oxide layer is basically composed of titanium dioxide (TiO2), another oxides as Ti O and Ti2O3 were also found in small amount. Carbon on implant surface was attributed to manufacturing process. Nitrogen, Phosphorous and Silicon appeared in smaller concentration on surface. There was no surface discrepancy among foreign and Brazilian made implants. SEM images were made on different magnification, 35 X to 3500 X, and showed similarity among as machined implants. Porous surface finishing implants presented distinct morphology. This result was attributed to differences on manufacturing process. Implant bioactivity was accessed through immersion on simulated body solution (SBF) in order to verify formation of an hydroxyapatite (HA) layer on surface. Samples were divided on three groups according to immersion time: G1 (7 days), G2 (14 days), G3 (21 days), and deep in SBF solution at 37 deg C. After being removed from solution, XPS analyses were made and then implants have been submitted to microprobe analysis. XPS showed some components of SBF solution on sample surface but microprobe examinations did not

  3. Coating, Titanium Dioxide and Solar Cell

    OpenAIRE

    Yang, Aohan

    2011-01-01

    The objective of this bachelor’s thesis is to get basic ideas about coating and a deep understanding of properties of titanium dioxide pigments as well as their application and performance in solar electricity energy technology. This thesis consists of three main parts, eight chapters. The first part is about basic knowledge of coating and tests of coated paper. Coating pigments are generally introduced in the part. In the second part, coating additives are introduced in details from ...

  4. Titanium dioxide in sunscreens - a safe and cheap solution?

    OpenAIRE

    Høiberg, Betina; Kofoed, Dan; Nissen, Rie; Larsen, Rune; Dawood, Jamil; Jupin, Victor

    2005-01-01

    Sunscreen formulations containing micronized or nano-structured titanium dioxide particles have been commercially available since the early 1990’s. A number of in vitro studies have presented evidence regarding the photogenotoxicity of titanium dioxide, as well as its function as a photocatalyst for the degradation of organic compounds, including the organic sunscreens present in lotion formulations. There has been some controversy as to whether titanium dioxide nanoparticles penetrate the ou...

  5. Optical properties and morphology of PECVD deposited titanium dioxide films

    OpenAIRE

    De Kowalski, J.; A. Sobczyk-Guzenda; H. Szymanowski; M. Gazicki-Lipman

    2009-01-01

    Purpose: The purpose of the present work is to compare the structure and optical properties, with respect to their potential optical applications, of titanium dioxide films synthesized with the PECVD method from two different precursor materials, namely titanium tetrachloride and titanium tetraethoxide (TEOT).Design/methodology/approach: Optical properties as well as thickness of the films were analyzed by means of Variable Angle Spectroscopic Ellipsometry (VASE). Morphology studies were carr...

  6. Cryogenic acoustic loss of pure and alloyed titanium

    Science.gov (United States)

    Matacz, A. L.; Veitch, P. J.; Blair, D. G.

    Low acoustic loss, high yield strength cryogenic materials are required for various high precision experiments, resonant-bar gravitational radiation antennae in particular. We report here acoustic loss measurements of commerically pure and alloyed titanium samples between 4.2 and 300 K. It is shown that machining damage of the surface significantly increased the acoustic loss of pure titanium, particularly below 100 K, and that the high strength alloy Ti-6AI-4V had significantly greater acoustic loss than pure titanium.

  7. Titanium alloys and porous coatings for orthopaedic applications

    OpenAIRE

    Vettorel, Matteo

    2014-01-01

    The project deals with titanium and titanium alloys as biomaterials for implants applications, focusing on their mechanical response under dynamic stresses occurring during common human activities. In the first part, the biomaterials requirements for orthopaedic implants, the properties and the processing of titanium alloys are described. From the combined biomechanics requirements, mechanical behaviour of the materials and the bone is analysed and the additional poroelastic behaviour is adde...

  8. Electrochemical Characterization of Surface Reactions on Biomedical Titanium alloys

    OpenAIRE

    Alkhateeb, Emad Hashim

    2008-01-01

    Titanium and its alloys are successfully used as implant materials for dental, orthopedic and osteosynthesis applications. The processes that take place at the implant tissue interface are important for the acceptance and integration of the implant. This thesis is divided into two parts: the first part deals with surface modification of titanium to improve the osseointegration, and the second part studies metastable pitting of titanium and its alloys. The weakly attached layer of a bone-like ...

  9. Optimisation of Sintering Factors of Titanium Foams Using Taguchi Method

    OpenAIRE

    Ahmad, S.; Muhamad, N; J. Sahari; K. R. Jamaludin

    2010-01-01

    Metal foams have the potential to be used in the production of bipolar plates in Polymer Electron Membrane Fuel Cells (PEMFC). In this paper, pure titanium was used to prepare titanium foam using the slurry method. The electrical conductivity is the most important parameter to be considered in the production of good bipolar plates. To achieve a high conductivity of the titanium foam, the effects of various parameters including temperature, time profile and composition have to be characterised...

  10. Stabilization of final titanium concentration in stainless steel

    International Nuclear Information System (INIS)

    The technology of combined alloying of stainless steel type 08-12Kh18N10T with 30%-ferrotitanium and metallic spongy titanium is developed and put into practice. This permits to stabilize titanium assimilation at the level of 40-60 % in two-slag melting process and to increase chromium recovering from the slag. Stabilization of titanium assimilation promotes its homogeneous distribution in final metal after electroslag remelting. 2 refs. 3 figs

  11. Titanium oxidation by rf inductively coupled plasma

    Science.gov (United States)

    Valencia-Alvarado, R.; de la Piedad-Beneitez, A.; López-Callejas, R.; Barocio, S. R.; Mercado-Cabrera, A.; Peña-Eguiluz, R.; Muñoz-Castro, A. E.; Rodríguez-Méndez, B. G.; de la Rosa-Vázquez, J. M.

    2014-05-01

    The development of titanium dioxide (TiO2) films in the rutile and anatase phases is reported. The films have been obtained from an implantation/diffusion and sputtering process of commercially pure titanium targets, carried out in up to 500 W plasmas. The experimental outcome is of particular interest, in the case of anatase, for atmospheric pollution degradation by photocatalysis and, as to the rutile phase, for the production of biomaterials required by prosthesis and implants. The reactor employed consists in a cylindrical pyrex-like glass vessel inductively coupled to a 13.56 MHz RF source. The process takes place at a 5×10-2 mbar pressure with the target samples being biased from 0 to -3000 V DC. The anatase phase films were obtained from sputtering the titanium targets over glass and silicon electrically floated substrates placed 2 cm away from the target. The rutile phase was obtained by implantation/diffusion on targets at about 700 °C. The plasma was developed from a 4:1 argon/oxygen mixture for ~5 hour processing periods. The target temperature was controlled by means of the bias voltage and the plasma source power. The obtained anatase phases did not require annealing after the plasma oxidation process. The characterization of the film samples was conducted by means of x-ray diffraction, scanning electron microscopy, x-ray photoelectron spectroscopy and Raman spectroscopy.

  12. Progress in Titanium Metal Powder Injection Molding

    Directory of Open Access Journals (Sweden)

    Randall M. German

    2013-08-01

    Full Text Available Metal powder injection molding is a shaping technology that has achieved solid scientific underpinnings. It is from this science base that recent progress has occurred in titanium powder injection molding. Much of the progress awaited development of the required particles with specific characteristics of particle size, particle shape, and purity. The production of titanium components by injection molding is stabilized by a good understanding of how each process variable impacts density and impurity level. As summarized here, recent research has isolated the four critical success factors in titanium metal powder injection molding (Ti-MIM that must be simultaneously satisfied—density, purity, alloying, and microstructure. The critical role of density and impurities, and the inability to remove impurities with sintering, compels attention to starting Ti-MIM with high quality alloy powders. This article addresses the four critical success factors to rationalize Ti-MIM processing conditions to the requirements for demanding applications in aerospace and medical fields. Based on extensive research, a baseline process is identified and reported here with attention to linking mechanical properties to the four critical success factors.

  13. Preparation of titanium diboride powders from titanium alkoxide and boron carbide powder

    Indian Academy of Sciences (India)

    Hamed Sinaei Pour Fard; Hamidreza Baharvandi

    2011-07-01

    Titanium diboride powders were prepared through a sol–gel and boron carbide reduction route by using TTIP and B4C as titanium and boron sources. The influence of TTIP concentration, reaction temperature and molar ratio of precursors on the synthesis of titanium diboride was investigated. Three different concentrations of TTIP solution, 0.033/0.05/0.1, were prepared and the molar ratio of B4C to TTIP varied from 1.3 to 2.5. The results indicated that as the TTIP concentration had an important role in gel formation, the reaction temperature and B4C to TTIP molar ratio showed obvious effects on the formation of TiB2. Pure TiB2 was prepared using molar composition of Ti : B4C = 1 : 2.3 and the optimum synthesis temperature was 1200°C.

  14. Characterization of Pectin Nanocoatings at Polystyrene and Titanium Surfaces

    DEFF Research Database (Denmark)

    Gurzawska, Katarzyna; Dirscherl, Kai; Yihua, Yu;

    2013-01-01

    study was to physically characterize and compare polystyrene and titanium surfaces nanocoated with different Rhamnogalacturonan-Is (RG-I) and to visualize RG-I nanocoatings. RG-Is from potato and apple were coated on aminated surfaces of polystyrene, titianium discs and titanium implants...... wettability, without any major effect on surface roughness (Sa, Sdr). Furthermore, we demonstrated that it is possible to visualize the pectin RG-Is molecules and even the nanocoatings on titanium surfaces, which have not been presented before. The comparison between polystyrene and titanium surface showed...

  15. Granulomatous disease associated with pulmonary deposition of titanium.

    Science.gov (United States)

    Redline, S; Barna, B P; Tomashefski, J F; Abraham, J L

    1986-10-01

    A patient presented with granulomatous lung disease associated with the pulmonary deposition of various metallic particles. To evaluate the relation between the metallic dust and the granulomatous process, lymphocyte transformation tests to aluminium sulphate, titanium chloride, beryllium sulphate, and nickel sulphate were performed. A lymphocyte proliferative response to titanium chloride was observed on two separate occasions; no responses to the other metals were shown. These results are consistent with hypersensitivity to titanium, and suggest, in this individual, a possible aetiological role between the inhalation of titanium and a granulomatous disease process.

  16. Formation of rolling and recrystallization textures in titanium and zirconium

    International Nuclear Information System (INIS)

    The results are presented of a study into the cold-rolling and recrystallization textures in iodide Ti and Zr subjected to 40-95% deformation. Pole figures for Ti and Zr after various deformations and after annealings at the temperatures of the beginning of crystallization are provided. It is shown that the cold-rolling texture forms less actively in zirconium than in titanium. After high deformations (over 80%) the rolling texture of zirconium becomes similar to that of titanium due to the similarity of their deformation mechanism. Texture strengthening in titanium and zirconium which is detected at the polygonization stage, more pronounced than in commercial titanium

  17. Determination of Trace Titanium by Catalytic Kinetic Spectrophtometry

    Institute of Scientific and Technical Information of China (English)

    ZHAI Qing-zhou; ZHANG Hao

    2007-01-01

    The optimum conditions of discoloring reaction of DBM-arsenazo oxidized by potassium bromate and catalyzed by trace titanium ( Ⅳ ) are studied and a new catalytic-kinetic spectrophotometric method for determination of trace titanium is developed. The linear range of determination of titanium ( Ⅳ ) is 0 - 48 ng/mL at 530 nm. The detection limit of the method is 0.084 ng/mL. The method is used for the determination of titanium in water samples and the analytical results are in excellent agreement with those by atomic absorption spectrometry.

  18. Glow discharge assisted oxynitriding process of titanium for medical application

    Science.gov (United States)

    Wierzchoń, Tadeusz; Czarnowska, Elżbieta; Grzonka, Justyna; Sowińska, Agnieszka; Tarnowski, Michał; Kamiński, Janusz; Kulikowski, Krzysztof; Borowski, Tomasz; Kurzydłowski, Krzysztof J.

    2015-04-01

    The plasma oxynitriding process is a prospective method of producing titanium oxides as an integral part of a diffusive nitrided surface layer on titanium implants. This hybrid process, which combines glow discharge assisted nitriding and oxidizing, permits producing TiO2 + Ti2N + αTi(N)-type diffusive surface layers. The oxynitrided surface layers improve the corrosion and wear resistance of the substrate material. Additionally, the nanocrystalline titanium oxide TiO2 (rutile) improves the biological properties of titanium and its alloys when in contact with blood, whereas the TiN + Ti2N + αTi(N) zone eliminates the effect of metalosis.

  19. Preparation and characterization of nitrogen-doped titanium dioxides

    Institute of Scientific and Technical Information of China (English)

    ZHU GuoPing; ZHOU KangGen

    2007-01-01

    A type of high visible-light active titanium oxinitride (TiO2_xNx) powder was prepared by a simple process: the calcination of the hydrated titanium dioxide at the atmosphere of ammonia-argon using a tubular electric furnace at high temperatures. The hydrated titanium dioxide was synthesized as the precursor of TiO2_xNx using titanic acid as raw material, which came from sulfate technique of producing titanium white. The effects of temperature and reaction time on the nitrogen content, grain size and crystal structure were studied. The visible-light activity and photocatalysis capability of the powder were also investigated.

  20. Biomimetic Multispiked Connecting Ti-Alloy Scaffold Prototype for Entirely-Cementless Resurfacing Arthroplasty Endoprostheses—Exemplary Results of Implantation of the Ca-P Surface-Modified Scaffold Prototypes in Animal Model and Osteoblast Culture Evaluation

    Directory of Open Access Journals (Sweden)

    Ryszard Uklejewski

    2016-06-01

    Full Text Available We present here—designed, manufactured, and tested by our research team—the Ti-alloy prototype of the multispiked connecting scaffold (MSC-Scaffold interfacing the components of resurfacing arthroplasty (RA endoprostheses with bone. The spikes of the MSC-Scaffold prototype mimic the interdigitations of the articular subchondral bone, which is the natural biostructure interfacing the articular cartilage with the periarticular trabecular bone. To enhance the osteoinduction/osteointegration potential of the MSC-Scaffold, the attempts to modify its bone contacting surfaces by the process of electrochemical cathodic deposition of Ca-P was performed with further immersion of the MSC-Scaffold prototypes in SBF in order to transform the amorphous calcium-phosphate coating in hydroxyapatite-like (HA-like coating. The pilot experimental study of biointegration of unmodified and Ca-P surface-modified MSC-Scaffold prototypes was conducted in an animal model (swine and in osteoblast cell culture. On the basis of a microscope-histological method the biointegration was proven by the presence of trabeculae in the interspike spaces of the MSC-Scaffold prototype on longitudinal and cross-sections of bone-implant specimens. The percentage of trabeculae in the area between the spikes of specimen containing Ca-P surface modified scaffold prototype observed in microCT reconstructions of the explanted joints was visibly higher than in the case of unmodified MSC-Scaffold prototypes. Significantly higher Alkaline Phosphatase (ALP activity and the cellular proliferation in the case of Ca-P-modified MSC-Scaffold pre-prototypes, in comparison with unmodified pre-prototypes, was found in osteoblast cell cultures. The obtained results of experimental implantation in an animal model and osteoblast cell culture evaluations of Ca-P surface-modified and non-modified biomimetic MSC-Scaffold prototypes for biomimetic entirely-cementless RA endoprostheses indicate the

  1. Selection of crucible oxides in molten titanium and titanium aluminum alloys by thermo-chemistry calculations

    OpenAIRE

    Kostov A.; Friedrich B

    2005-01-01

    Titanium and its alloys interstitially dissolve a large amount of impurities such as oxygen and nitrogen, which degrade the mechanical and physical properties of alloys. On the other hand crucible oxides based on CaO, ZrO2 Y2O3, etc., and their spinels (combination of two or more oxides) can be used for melting titanium and its alloys. However, the thermodynamic behavior of calcium, zirconium, yttrium on the one side, and oxygen on the other side, in molten Ti and Ti-Al alloys have not been m...

  2. Influence of titanium content on wear resistance of electrolytic low-titanium eutectic Al-Si piston alloys

    OpenAIRE

    Yan Shuqing; Xie Jingpei; Wang Jiefang

    2008-01-01

    The wear resistance of six kinds of the electrolytic low-titanium eutectic Al-Si piston alloys with various Ti content ranging from 0.00wt.% to 0.21wt.% has been studied. A new method of adding Ti is adopted in the electrolytic low-titanium aluminum alloy ingots. The electrolytic low-titanium eutectic Al-Si piston alloys are produced by remelting the electrolytic low-titanium aluminum alloy, crystal silicon, pure magnesium, Al-50%Cu and Al-10%Mn master alloy. The wear experiments are conducte...

  3. Effect of titanium nitride/titanium coatings on the stress corrosion of nickel-titanium orthodontic archwires in artificial saliva

    Science.gov (United States)

    Liu, Jia-Kuang; Liu, I.-Hua; Liu, Cheng; Chang, Chen-Jung; Kung, Kuan-Chen; Liu, Yen-Ting; Lee, Tzer-Min; Jou, Jin-Long

    2014-10-01

    The purpose of this investigation was to develop titanium nitride (TiN)/titanium (Ti) coating on orthodontic nickel-titanium (NiTi) wires and to study the stress corrosion of specimens in vitro, simulating the intra-oral environment in as realistic a manner as possible. TiN/Ti coatings were formed on orthodontic NiTi wires by physical vapor deposition (PVD). The characteristics of untreated and TiN/Ti-coated NiTi wires were evaluated by measurement of corrosion potential (Ecorr), corrosion current densities (Icorr), breakdown potential (Eb), and surface morphology in artificial saliva with different pH and three-point bending conditions. From the potentiodynamic polarization and SEM results, the untreated NiTi wires showed localized corrosion compared with the uniform corrosion observed in the TiN/Ti-coated specimen under both unstressed and stressed conditions. The bending stress influenced the corrosion current density and breakdown potential of untreated specimens at both pH 2 and pH 5.3. Although the bending stress influenced the corrosion current of the TiN/Ti-coated specimens, stable and passive corrosion behavior of the stressed specimen was observed even at 2.0 V (Ag/AgCl). It should be noted that the surface properties of the NiTi alloy could determine clinical performance. For orthodontic application, the mechanical damage destroys the protective oxide film of NiTi; however, the self-repairing capacity of the passive film of NiTi alloys is inferior to Ti in chloride-containing solutions. In this study, the TiN coating was found able to provide protection against mechanical damage, while the Ti interlayer improved the corrosion properties in an aggressive environment.

  4. Laboratory technique for coloring titanium abutments to improve esthetics.

    Science.gov (United States)

    Wadhwani, Chandur P K; O'Brien, Richard; Kattadiyil, Mathew T; Chung, Kwok-Hung

    2016-04-01

    Titanium alloys are used for implant abutments onto which prostheses are attached. One major disadvantage of titanium abutments is their esthetics; the metallic gray color may show through the restorative material or through surrounding tissues. A laboratory technique using readily available household items is described that can alter the abutment color by anodization. PMID:26723096

  5. Hydrophilicity of titanium oxide coatings with the addition of silica

    International Nuclear Information System (INIS)

    This work investigated hydrophilicity between titanium oxide coatings with and without addition of silica. A sol of titania and silica was prepared for sol-gel coating. The sol of titanium oxide is aqueous, and the mixed sol is transparent with a pH value of 8.0. Coating was prepared by spraying mixed sol over a heated substrate. The titanium oxide sol was prepared by using an inorganic titanium salt. A silica sol was then added to titanium oxide sol obtain the mixed sol. Thickness of the coatings were between 20 and 80 nm. The sols were characterized by IR spectroscopy. AFM was used to investigate the coating surface structure and roughness. The crystalline size of coating surface for the mixed oxides was little greater than for the pure titanium oxide. The crystalline phase was investigated using X-ray diffraction. The hydrophilicity of coatings was studied with UV and sunlight exposure and by measurement of contact angle change of droplets of water. Through the investigation of change of contact angle and water droplets on the surface after UV exposure and sunlight radiation, it can be concluded that hydrophilicity of mixed coatings with low temperature heat-treatment of titanium oxide and silica are much better than a pure titanium oxide coating. This effect makes for an improved self-cleaning coating

  6. 40 CFR 721.10021 - Magnesium potassium titanium oxide.

    Science.gov (United States)

    2010-07-01

    ... § 721.63 respirator requirements may request to do so under 40 CFR 721.30. Persons whose § 721.30... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Magnesium potassium titanium oxide... Specific Chemical Substances § 721.10021 Magnesium potassium titanium oxide. (a) Chemical substance...

  7. 40 CFR 721.10031 - Lithium potassium titanium oxide.

    Science.gov (United States)

    2010-07-01

    ... requirements may request to do so under 40 CFR 721.30. Persons whose § 721.30 requests to use the NCELs... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Lithium potassium titanium oxide. 721... Substances § 721.10031 Lithium potassium titanium oxide. (a) Chemical substance and significant new...

  8. Radio frequency plasma treatments on titanium for enhancement of bioactivity.

    NARCIS (Netherlands)

    Lopez-Heredia, M.A.; Legeay, G.; Gaillard, C.; Layrolle, P.

    2008-01-01

    Titanium and its alloys, when treated in alkali solutions, are able to form calcium phosphate coatings on their surface after immersion in supersaturated solutions. In this study, the surfaces of titanium alloy discs were modified by an alkali treatment and a radio frequency (RF) plasma procedure (1

  9. Classification of titanium dioxide; Clasificacion del dioxido de titanio

    Energy Technology Data Exchange (ETDEWEB)

    Macias B, L.R. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Garcia C, R.M.; Maya M, M.E. [Secretaria de Hacienda y Credito Publico de Mexico, Mexico (Mexico); Ita T, A. De [Universidad Autonoma Metropolitana Azcapotzalco, Mexico (Mexico); Palacios G, J. [Instituto Politecnico Nacional (Mexico)

    2002-07-01

    In this work the X-ray diffraction (XRD), Scanning Electron Microscopy (Sem) and the X-ray Dispersive Energy Spectroscopy techniques are used with the purpose to achieve a complete identification of phases and mixture of phases of a crystalline material as titanium dioxide. The problem for solving consists of being able to distinguish a sample of titanium dioxide being different than a titanium dioxide pigment. A standard sample of titanium dioxide with NIST certificate is used, which indicates a purity of 99.74% for the TiO{sub 2}. The following way is recommended to proceed: a)To make an analysis by means of X-ray diffraction technique to the sample of titanium dioxide pigment and on the standard of titanium dioxide waiting not find differences. b) To make a chemical analysis by the X-ray Dispersive Energy Spectroscopy via in a microscope, taking advantage of the high vacuum since it is oxygen which is analysed and if it is concluded that the aluminium oxide appears in a greater proportion to 1% it is established that is a titanium dioxide pigment, but if it is lesser then it will be only titanium dioxide. This type of analysis is an application of the nuclear techniques useful for the tariff classification of merchandise which is considered as of difficult recognition. (Author)

  10. UV photofunctionalization promotes nano-biomimetic apatite deposition on titanium

    Directory of Open Access Journals (Sweden)

    Saita M

    2016-01-01

    Full Text Available Makiko Saita,1 Takayuki Ikeda,1,2 Masahiro Yamada,1,3 Katsuhiko Kimoto,4 Masaichi Chang-Il Lee,5 Takahiro Ogawa1 1Division of Advanced Prosthodontics, Weintraub Center for Reconstructive Biotechnology, UCLA School of Dentistry, Los Angeles, CA, USA; 2Department of Complete Denture Prosthodontics, Nihon University School of Dentistry, Yokosuka, Japan; 3Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Miyagi, Japan; 4Department of Prosthodontics and Oral Rehabilitation, 5Yokosuka-Shonan Disaster Health Emergency Research Center and ESR Laboratories, Kanagawa Dental University Graduate School of Dentistry, Yokosuka, Japan Background: Although biomimetic apatite coating is a promising way to provide titanium with osteoconductivity, the efficiency and quality of deposition is often poor. Most titanium implants have microscale surface morphology, and an addition of nanoscale features while preserving the micromorphology may provide further biological benefit. Here, we examined the effect of ultraviolet (UV light treatment of titanium, or photofunctionalization, on the efficacy of biomimetic apatite deposition on titanium and its biological capability.Methods and results: Micro-roughed titanium disks were prepared by acid-etching with sulfuric acid. Micro-roughened disks with or without photofunctionalization (20-minute exposure to UV light were immersed in simulated body fluid (SBF for 1 or 5 days. Photofunctionalized titanium disks were superhydrophilic and did not form surface air bubbles when immersed in SBF, whereas non-photofunctionalized disks were hydrophobic and largely covered with air bubbles during immersion. An apatite-related signal was observed by X-ray diffraction on photofunctionalized titanium after 1 day of SBF immersion, which was equivalent to the one observed after 5 days of immersion of control titanium. Scanning electron microscopy revealed nodular apatite deposition

  11. Ballistic Experiments with Titanium and Aluminum Targets

    Energy Technology Data Exchange (ETDEWEB)

    Gogolewski, R.; Morgan, B.R.

    1999-11-23

    During the course of the project we conducted two sets of fundamental experiments in penetration mechanics in the LLNL Terminal Ballistics Laboratory of the Physics Directorate. The first set of full-scale experiments was conducted with a 14.5mm air propelled launcher. The object of the experiments was to determine the ballistic limit speed of 6Al-4V-alloy titanium, low fineness ratio projectiles centrally impacting 2024-T3 alloy aluminum flat plates and the failure modes of the projectiles and the targets. The second set of one-third scale experiments was conducted with a 14.5mm powder launcher. The object of these experiments was to determine the ballistic limit speed of 6Al-4V alloy titanium high fineness ratio projectiles centrally impacting 6Al-4V alloy titanium flat plates and the failure modes of the projectiles and the target. We employed radiography to observe a projectile just before and after interaction with a target plate. Early on, we employed a non-damaging ''soft-catch'' technique to capture projectiles after they perforated targets. Once we realized that a projectile was not damaged during interaction with a target, we used a 4-inch thick 6061-T6-alloy aluminum witness block with a 6.0-inch x 6.0-inch cross-section to measure projectile residual penetration. We have recorded and tabulated below projectile impact speed, projectile residual (post-impact) speed, projectile failure mode, target failure mode, and pertinent comments for the experiments. The ballistic techniques employed for the experiments are similar to those employed in an earlier study.

  12. Combustion synthesis of porous titanium microspheres

    International Nuclear Information System (INIS)

    The synthesis of titanium porous microspheres by a combustion technique was studied under an argon atmosphere by using a TiO2 − 2.5Mg reactive mixture. The precursor, a fine TiO2 powder, was thermally treated in the range 600–1300 °C prior to the combustion experiments. TiO2 microspheres whose diameters were between 10 and 50 μm were obtained from precursor particles annealed in the range 900–1100 °C. A biphase product consisting of Ti and MgO phases was obtained when the TiO2 microspheres were reduced with Mg. The spherical morphology of the final particles was retained despite the relatively high combustion temperatures (1630–1670 °C) used in this study. Moreover, porous titanium microspheres were obtained when the MgO particles were dissolved using acid leaching. Scanning electron microscopy (SEM) images of the microspheres suggested that the spherical structure contained ∼0.5–2.0-μm-diameter porous windows. The Brunauer–Emmett–Teller (BET) surface area of the Ti microspheres was determined to be 2.8 m2 g−1. - Highlights: • TiO2 + 2.5Mg mixture was combusted under argon pressure to produce titanium microspheres. • Microspheres with a porous framework structure were obtained at 1630–1670 °C. • The microspheres exhibited 10–50 μm average diameters with porous window of ∼0.5–2.0 μm and BET surface area of 2.8 m2 g−1. - Graphical abstract: Display Omitted

  13. Intermetallic communication in titanium(IV) ferrocenyldiketonates.

    Science.gov (United States)

    Dulatas, Lea T; Brown, Seth N; Ojomo, Edema; Noll, Bruce C; Cavo, Matthew J; Holt, Paul B; Wopperer, Matthew M

    2009-11-16

    A tetradentate bis(ferrocenyldiketonate) ligand, Fc(2)BobH(2), is prepared via Claisen condensation of acetylferrocene and 2,2'-biphenyldiacetyl chloride, and is metalated with titanium(IV) isopropoxide to give (Fc(2)Bob)Ti(O(i)Pr)(2) in good yield. The isopropoxide groups are replaced with di(4-nitrophenyl)phosphate groups on treatment with the corresponding acid, and with chlorides on treatment with trimethylsilyl chloride. Metathesis with catechol leads to the bis(o-hydroxyphenoxide) complex rather than the chelating catecholate complex. Hydrolysis selectively gives the mu-oxo trimer (Delta,Delta,Delta)/(Lambda,Lambda,Lambda)-{(Fc(2)Bob)Ti(mu-O)}(3). The solid-state structures of the mu-oxo trimer and the bis(o-hydroxyphenoxide) complex show that the ferrocene substituents are oriented proximal to the biphenyl backbone rather than pointed out toward the exogenous groups. The complexes show dramatic changes in color depending on the bound anions, ranging from the red isopropoxide (lambda(max) = 489 nm) to the green bis(di(4-nitrophenyl)phosphate) (lambda(max) = 653 nm). The oxidation potentials of the ferrocenes show modest shifts based on the titanium environment, but the redox potentials of the two ferrocenes are never separated by more than 60 mV. These results and those of density-functional theory (DFT) calculations indicate that the titanium interacts principally with the lowest unoccupied molecular orbital (LUMO) of the ferrocenyldiketonate and very little with its highest occupied molecular orbital (HOMO).

  14. Growth of anatase titanium dioxide nanotubes via anodization

    Directory of Open Access Journals (Sweden)

    Ed Adrian Dilla

    2012-06-01

    Full Text Available In this work, titanium dioxide nanotubes were grown via anodization of sputtered titanium thin films using different anodization parameters in order to formulate a method of producing long anatase titanium dioxide nanotubes intended for solar cell applications. The morphological features of the nanotubes grown via anodization were explored using a Philips XL30 Field Emission Scanning Electron Microscope. Furthermore, the grown nanotubes were also subjected to X-ray diffraction and Raman spectroscopy in order to investigate the effect of the predominant crystal orientation of the parent titanium thin film on the crystal phase of the nanotubes. After optimizing the anodization parameters, nanotubes with anatase TiO2 crystal phase and tube length more than 2 microns was produced from parent titanium thin films with predominant Ti(010 crystal orientation and using ammonium fluoride in ethylene glycol as an electrolyte with a working voltage equal to 60V during 1-hour anodization runs.

  15. Recent Advances in the Hot Working of Titanium Alloys

    Institute of Scientific and Technical Information of China (English)

    DANG Xiao-ling

    2012-01-01

    In this paper, recent advances in titanium alloy processing are reviewed. The casting, superplastic forming, friction stir welding and thermohydrogen processing of titanium alloys are developed. The great cost saving results from using casting comparing with the conventional machining for rings. The superplastic forming of titanium alloys is a feasible manufacturing technology for civil and military aircraft. The friction stir welding leds to the production of fully-formed, high quality friction stirwelds. In thermohydrogen processing, the high diffusivity of hydrogen in titanium is firstly used to add hydrogen to titanium alloys by controlled diffusion from a hydrogen environment , after thermohydrogen processing, to remove it by a controlled vacuum anneal so as to improve processing and mechanical properties.

  16. Electrochemical Investigation of Doped Titanium Dioxide

    OpenAIRE

    J. W. J. Hamilton; Byrne, J A; McCullagh, C.; Dunlop, P. S. M.

    2008-01-01

    Thin films of transition-metal doped (0.2, 1.0, and 5.0 atom%) TiO2 were prepared on titanium foil using a sol-gel route catalyzed by ammonium acetate. Dopants investigated were the fourth-period transition metals. The prepared films were characterised by Raman spectroscopy, Auger electron spectroscopy, and photoelectrochemical methods. The films doped with transition metals showed a lower photocurrent response than undoped samples. No major red shift in the photocurrent response spectra of t...

  17. Magnetic susceptibility of tetragonal titanium dioxide

    Science.gov (United States)

    Senftle, F.E.; Pankey, T.; Grant, F.A.

    1960-01-01

    Careful measurements have been made of the magnetic susceptibility of the rutile and anatase crystalline forms of titanium dioxide. The magnetic susceptibility of a single crystal of high-purity rutile was found to be (0.067??0.0015)??10-6 emu per gram, and was temperature-independent from 55??to 372??K. Difficulty was encountered in obtaining a good value of the magnetic susceptibility of anatase because of impurities. However, a value of 0.02??10-6 emu per gram was obtained as a maximum value for anatase powder. A discussion is given for the different values obtained for anatase and rutile. ?? 1960 The American Physical Society.

  18. Titanium-enhanced Raman microcavity laser.

    Science.gov (United States)

    Deka, Nishita; Maker, Ashley J; Armani, Andrea M

    2014-03-15

    Whispering gallery mode microcavities are ideally suited to form microlaser devices because the high circulating intensity within the cavity results in ultralow lasing thresholds. However, to achieve low-threshold Raman lasing in silica devices, it is necessary to have quality factors above 100 million. One approach to circumvent this restriction is to intercalate a sensitizer into the silica, which increases the Raman gain. In the present work, we demonstrate a Raman laser based on a titanium sensitized silica solgel coated toroidal microcavity. By tuning the concentration of the Ti, the Raman efficiency improves over 3× while maintaining sub-mW thresholds. PMID:24690786

  19. Laser Welding of TC-1 Titanium Alloy

    Institute of Scientific and Technical Information of China (English)

    Hanbin DU; Lunji HU; Xiyuan HU; Jianhua LIU

    2003-01-01

    The technology of CO2 laser welding and joint properties of titanium alloy were investigated. The problem of moltenpool protection was resolved by designing a shielding trailer and a special clamp. Joints with silvery appearance wereobtained, which have no pore and crack. In addition, the welding speed could reach 3 m/min for the plate of 1.5 mmthickness being penetrated. The reason of the porosity formation in partial penetration joints is that the keyholescan be easily cut apart in the radial direction, which makes the gas enclosed in the molten pool. The surface oxideof specimens can not affect the porosity formation in welds directly.

  20. Characterization of cellular titanium for biomedical applications

    Science.gov (United States)

    Hrabe, Nikolas Wilson

    By controlling structural features (relative density, pore size, strut size) of cellular titanium (also known as porous titanium), the mechanical properties can be optimized to reduce the effects of stress shielding currently observed in load-bearing bone replacement implants. Thermal gravimetric analysis of a sacrificial scaffold system lead to important processing modifications in an attempt to meet chemistry requirements for surgical grade titanium not met in previous work. Despite these modifications chemistry did not meet requirements for carbon, nitrogen, or oxygen. Commercially pure titanium (CPTi) porous structures were made over a range of relative densities using laser engineered net shaping (LENS). From monotonic compression tests, yield strength and elastic modulus in the range of bone were achieved but did not scale with relative density as predicted by the Gibson-Ashby analytical model. Compression-compression fatigue resistance was high, as no failures were observed for test stresses up to 133% yield strength, which is thought to be influenced by the dense exterior shell of the samples. Structures were also fabricated over a range of relative densities using selective electron beam melting (SEBM or EBM), and structural, mechanical, and in-vitro properties were measured for three materials (as-built Ti-6A1-4V, Ti-6A1-4V after hot isostatic pressing (HIPing), and as-built CPTi). For structures of all three materials, yield strength and elastic modulus was within the range for bone. Numerical modeling results suggested cell shape and sintered particles on strut surfaces affect the scaling of elastic modulus with relative density and lead to the observed difference from the Gibson-Ashby model. Normalized fatigue strengths at 106 cycles ranged from 0.150.25 for as-built Ti-6A1-4V structures, which is lower than expected. Results for HIPed Ti-6A1-4V structures and CPTi structures suggest that stress concentrations from closed porosity within struts as well

  1. Water-soluble titanium alkoxide material

    Science.gov (United States)

    Boyle, Timothy J.

    2010-06-22

    A water soluble, water stable, titanium alkoxide composition represented by the chemical formula (OC.sub.6H.sub.6N).sub.2Ti(OC.sub.6H.sub.2(CH.sub.2N(CH.sub.3).sub.2).sub- .3-2,4,6).sub.2 with a theoretical molecular weight of 792.8 and an elemental composition of 63.6% C, 8.1% H, 14.1% N, 8.1% O and 6.0% Ti.

  2. Titanium alloy corrosion in nuclear waste environments

    International Nuclear Information System (INIS)

    A corrosion study has been conducted on the titanium alloys Ti-50A, TiCode 12, and Ti-Pd to evaluate their suitability as a long lifetime (300 to 600 year) canister material for the isolation of nuclear wastes. TiCode 12, selected as the primary candidate material, is shown to be very resistant to environmental attack. Results of electrochemical, general corrosion, and stress corrosion cracking experiments are presented. These data, including those from severe overtests, have shown that TiCode 12 is a viable candidate material for long-term waste isolation. 17 figures

  3. Internal adaptation of cast titanium crowns

    Directory of Open Access Journals (Sweden)

    Sicknan Soares da Rocha

    2007-08-01

    Full Text Available As the adaptation of titanium crowns obtained by Rematitan Plus investment, specific for titanium, is not recognized to be suitable, this study evaluated the effect of the concentration of the specific liquid and the temperature of the mold of investments on the internal misfit of crowns cast on commercially pure titanium. Individual dies of epoxy resin were obtained, representing teeth prepared for full-crown restoration with a 6-degree axial surface convergence angle and shoulder (1.0 mm. For the waxing of each crown, a ring-shaped stainless steel matrix (8.0mm internal diameter; 7.5 mm height was adapted above the individual dies of epoxy resin. The Rematian Plus investment was mixed according to the manufacturer's instructions using two different concentrations of the specific liquid: 100%, 75%. Casting was performed in a Discovery Plasma Ar-arc vacuum-pressure casting machine with molds at temperatures of 430ºC, 515ºC and 600ºC. The crowns were cleaned individually in a solution (1% HF + 13% HNO3 for 10 min using a ultrasonic cleaner, with no internal adaptations, and luted with zinc phosphate cement under a 5 kg static load. The crown and die assemblies were embedded in resin and sectioned longitudinally. The area occupied by cement was observed using stereoscopic lens (10X and measured by the Leica Qwin image analysis system (mm². The data for each experimental condition (n=8 were analyzed by Kruskal-Wallis non-parametric test (á=0.05. The results showed that liquid dilution and the increase in mold temperature did not significantly influence the levels of internal fit of the cast titanium crowns. The lowest means (±SD of internal misfit were obtained for the 430ºC/100%: (7.25 mm² ±1.59 and 600ºC/100% (8.8 mm² ±2.25 groups, which presented statistically similar levels of internal misfit.

  4. Laser-TIG Welding of Titanium Alloys

    Science.gov (United States)

    Turichin, G.; Tsibulsky, I.; Somonov, V.; Kuznetsov, M.; Akhmetov, A.

    2016-08-01

    The article presents the results of investigation the technological opportunity of laser-TIG welding of titanium alloys. The experimental stand for implementation of process with the capability to feed a filler wire was made. The research of the nature of transfer the filler wire into the welding pool has been demonstrated. The influence of distance between the electrode and the surface of the welded plates on the stability of the arc was shown. The relationship between welding velocity, the position of focal plane of the laser beam and the stability of penetration of plates was determined.

  5. Fatigue crack growth behavior of titanium foams for medical applications

    International Nuclear Information System (INIS)

    Research highlights: → Titanium foam with 60% porosity has higher Paris exponent than solid titanium. → High Paris exponents are most likely caused by crack closure and crack bridging. → Solid coating on titanium foam results in lower crack growth than uncoated foam. → The load ratio had a negligible effect on the FCG behavior of both materials. → Medical applications of titanium foams are not limited by their crack growth rate. - Abstract: There is an urgent need to understand the failure behavior of titanium foams because of their promising application as load-bearing implant materials in biomedical applications. Following our recent study on fracture toughness of titanium foams , this paper investigates the mode I fatigue crack propagation in 60% porous open pore titanium foams both with and without solid coated surface. Fatigue crack propagation tests were performed on compact tension specimens at load ratios of R = 0.1 and R = 0.5 and the fracture surfaces were examined using scanning electron microscopy. The crack growth rate, da/dN, versus the stress intensity factor range, ΔK, curves were measured and compared using two different techniques; image processing and compliance methods. The crack extension rates were well described by ΔK, using the Paris-power law approach. Coated and non-coated titanium foams with 60% porosity had a significantly higher Paris exponent than solid titanium, which can be explained by crack closure and crack bridging. It was also shown that the fatigue crack grows along the centerline, following the weakest path throughout the foam. The results obtained from this work provide important information for evaluating the structural integrity of porous titanium components in the future biomedical applications.

  6. RESEARCH INVESTIGATIONS OF WATER PURIFICATION PROCESS WITH PHOTOCATALYST BASED ON POROUS TITANIUM WITH NANOPARTICLES OF TITANIUM DIOXIDE

    OpenAIRE

    L. Pilinevich; V. Martsul; M. Zalesskaya

    2013-01-01

    The paper presents results of the investigations on the water purification process with the help of photocatalysis using the photocatalyst which is developed on the basis of porous titanium with the layer of nanoparticle layer of titanium dioxide and an experimental plant. The investigations results have shown high efficiency of the developed photocatalytic materials and a water purification plants

  7. Application of sintered titanium alloys to metal denture bases: a study of titanium powder sheets for complete denture base.

    Science.gov (United States)

    Doi, H; Harrori, M; Hasegawa, K; Yoshinari, M; Kawada, E; Oda, Y

    2001-02-01

    The purpose of this study was the fabrication of titanium powder sheets to enable the application of sintered titanium alloys as metal denture bases. The effects of titanium particle shape and size, binder content, and plasticizer content on the surface smoothness, tensile strength and elongation of titanium powder sheets was investigated. To select a suitable ratio of powdered metal contents for application as a metal denture base, the effects of aluminum content in Ti sheets and various other powder metal contents in Ti-Al sheets on the density, sintering shrinkage, and bending strength were evaluated. Based on the results of the above experiments, we developed a mixed powder sheet composed of 83Ti-7Al-10Cr with TA45 titanium powder (atomized, -45 microm), and 8 mass% binder content. This titanium alloy sheet had good formability and ductility. Its sintered titanium alloy had a density of 3.2 g/cm3, sintering shrinkage of 3.8%, and bending strength of 403 MPa. The titanium alloy sheet is clinically acceptable for fabricating denture bases.

  8. High Frequency Discharge Plasma Induced Grafting of Polystyrene onto Titanium Dioxide Powder

    Institute of Scientific and Technical Information of China (English)

    ZHONG Shaofeng; OU Qiongrong; MENG Yuedong

    2007-01-01

    Grafting of polystyrene (PS) onto titanium dioxide powder was investigated. The graft polymerization reaction was induced by high frequency discharge produced N2 plasma treatment of the surfaces of titanium dioxide. IR , XPS and TGA results show that PS was grafted on the titanium dioxide powder. And the crystal structure of the titanium dioxide powder observed by XRD was unchanged after plasma treatment.

  9. Pemesinan Ramah lingkungan Bahan Aero-Angkasa Paduan Titanium Menggunakan Pahat Karbida

    OpenAIRE

    Ginting, Armansyah

    2008-01-01

    Hampir enam dekade telah berlalu sejak awal paduan titanium (titanium alloys) digunakan sebagai bahan baku struktur produk industri aeroangkasa (aerospace industries), namun usaha untuk meningkatkan ketermesinan yang rendah (low machinability) bahan ini masih berlanjut hingga hari ini. Sifat ketermesinan yang rendah ini menyebabkan paduan titanium disebut difficult-to-machine material. Penelitian untuk meningkatkan ketermesinan paduan titanium ini bertumpu pada kajian pre...

  10. Powder Injection Molding of Titanium Components

    Energy Technology Data Exchange (ETDEWEB)

    Simmons, Kevin L.; Nyberg, Eric A.; Weil, K. Scott; Miller, Megan R.

    2005-01-01

    Powder injection molding (PIM) is a well-established, cost-effective method of fabricating small-to-moderate size metal components. Derived from plastic injection molding and employing a mixture of metal powder and plastic binder, the process has been used with great success in manufacturing a wide variety of metal products, including those made from stainless steel, nickel-based superalloys, and copper alloys. Less progress has been achieved with titanium and other refractory metal alloys because of problems with alloy impurities that are directly attributable to the injection molding process. Specifically, carbon, oxygen, and nitrogen are left behind during binder removal and become incorporated into the chemistry and microstructure of the material during densification. Even at low concentration, these impurities can cause severe degradation in the mechanical properties of titanium and its alloys. We have developed a unique blend of PIM constituents where only a small volume fraction of binder (~5 – 10 vol%) is required for injection molding; the remainder of the mixture consists of the metal powder and binder solvent. Because of the nature of decomposition in the binder system and the relatively small amount used, the binder is eliminated almost completely from the pre-sintered component during the initial stage of a two-step heat treatment process. Results will be presented on the first phase of this research, in which the binder, injection molding, de-binding and sintering schedule were developed. Additional data on the mechanical and physical properties of the material produced will be discussed.

  11. Fatigue behaviour of titanium dental endosseous implants

    Directory of Open Access Journals (Sweden)

    Alessandro Scicutelli

    2011-10-01

    Full Text Available In this work two different titanium dental implants are analyzed in order to evaluate their mechanical strength. An ad-hoc designed experimental apparatus is prepared to test against fatigue these implants in a way that approximates as much as possible the actual stresses occurring during mastication motion. The results of these endurance tests are summarized in the form of Wohler-type diagrams showing the duration of a specific implant for different applied loads. These plots show a fatigue limit below which the implants could resist indefinitely. Other aspects of this research concern the influence of a potentially corrosive medium and the analysis of the deformation and failure of the specimens. During fatigue cycling, the titanium implants do not seem to be affected by a more aggressive environment, such as a saline solution. The analysis of the broken specimen allowed the crack initiation sites and the type of fracture propagation to be investigated in depth. In all the considered implants fatigue cracks were seen to initiate preferentially from sites in which the tensile stress concentration is the highest. The results of a finite element analysis performed on one of the specimens is in good agreement with the failure mode observed after the tests. The SEM fracture surface analysis shows a clear similarity between the fracture mode of the tested implants and of the actual implants broken after a certain operating period.

  12. Nickel-titanium alloys: a systematic review

    Directory of Open Access Journals (Sweden)

    Marcelo do Amaral Ferreira

    2012-06-01

    Full Text Available OBJECTIVE: A systematic review on nickel-titanium wires was performed. The strategy was focused on Entrez-PubMed-OLDMEDLINE, Scopus and BioMed Central from 1963 to 2008. METHODS: Papers in English and French describing the behavior of these wires and laboratorial methods to identify crystalline transformation were considered. A total of 29 papers were selected. RESULTS: Nickel-titanium wires show exceptional features in terms of elasticity and shape memory effects. However, clinical applications request a deeper knowledge of these properties in order to allow the professional to use them in a rational manner. In addition, the necessary information regarding each alloy often does not correspond to the information given by the manufacturer. Many alloys called "superelastic" do not present this effect; they just behave as less stiff alloys, with a larger springback if compared to the stainless steel wires. CONCLUSIONS: Laboratory tests are the only means to observe the real behavior of these materials, including temperature transition range (TTR and applied tensions. However, it is also possible to determine in which TTR these alloys change the crystalline structure.

  13. Ballistic Limit Equation for Single Wall Titanium

    Science.gov (United States)

    Ratliff, J. M.; Christiansen, Eric L.; Bryant, C.

    2009-01-01

    Hypervelocity impact tests and hydrocode simulations were used to determine the ballistic limit equation (BLE) for perforation of a titanium wall, as a function of wall thickness. Two titanium alloys were considered, and separate BLEs were derived for each. Tested wall thicknesses ranged from 0.5mm to 2.0mm. The single-wall damage equation of Cour-Palais [ref. 1] was used to analyze the Ti wall's shielding effectiveness. It was concluded that the Cour-Palais single-wall equation produced a non-conservative prediction of the ballistic limit for the Ti shield. The inaccurate prediction was not a particularly surprising result; the Cour-Palais single-wall BLE contains shield material properties as parameters, but it was formulated only from tests of different aluminum alloys. Single-wall Ti shield tests were run (thicknesses of 2.0 mm, 1.5 mm, 1.0 mm, and 0.5 mm) on Ti 15-3-3-3 material custom cut from rod stock. Hypervelocity impact (HVI) tests were used to establish the failure threshold empirically, using the additional constraint that the damage scales with impact energy, as was indicated by hydrocode simulations. The criterion for shield failure was defined as no detached spall from the shield back surface during HVI. Based on the test results, which confirmed an approximately energy-dependent shield effectiveness, the Cour-Palais equation was modified.

  14. Optimal welding of beta titanium orthodontic wires.

    Science.gov (United States)

    Nelson, K R; Burstone, C J; Goldberg, A J

    1987-09-01

    Today the orthodontist is confronted by an array of new orthodontic wire materials that, when applied to appliance design, can vastly increase the flexibility and versatility of therapy. Welded joints, especially for the newer titanium alloy wires, provide a means to extend the useful applications of these materials. The purpose of this study was to determine the optimum settings for electrical resistance welding of various configurations of titanium-molybdenum (TMA) wires. Specimens were of a t-joint configuration and were mechanically tested in torsion to simulate the failure mode most often observed in clinical practice. Variables included wire size, wire orientation, and welding voltage. Results indicated that excellent welds can be obtained with very little loss of strength and ductility in the area of the weld joint. Torsional loads at failure were at least 90% of the unwelded base material. Although a wide range of voltage settings resulted in high-strength welds, typically a narrow range of voltages yielded optimal ductility.

  15. Hydrogenation-induced microstructure changes in titanium

    Energy Technology Data Exchange (ETDEWEB)

    Laptev, R., E-mail: laptevrs@tpu.ru; Lider, A., E-mail: lider@tpu.ru; Bordulev, Yu., E-mail: bus@tpu.ru; Kudiiarov, V., E-mail: kudiyarov@tpu.ru; Garanin, G., E-mail: garaningv@tpu.ru

    2015-10-05

    Highlights: • Hydrogen induced microstructure changes in Ti studied by PL and DB spectroscopies. • Vacancies and vacancy clusters formed at concentration from 1.31 to 2.27 at.%. • Cluster-hydrogen and vacancy-hydrogen complexes formed at concentration up to 32 at.%. - Abstract: Microstructure changes of commercially pure titanium in a wide range of hydrogen concentrations from 0.8 at.% to 32.0 at.% were studied by means of positron lifetime spectroscopy and Doppler broadening spectroscopy. We have obtained new experimental data on the evolution of positron annihilation parameters τ{sub f}, τ{sub d} and their corresponding intensities I{sub f}, I{sub d,} as well as relative changes of parameters S/S{sub 0} and W/W{sub 0} depending on the hydrogen concentration in commercially pure titanium after gas-phase hydrogenation at 873 K. Results suggest that the hydrogenation of Ti samples up to concentrations of 1.31–2.27 at.% and subsequent cooling to a room temperature leads to the formation of vacancies and vacancy clusters. Further increase of the hydrogen concentration up to 32.0 at.% leads to the interaction of hydrogen with these defects and the formation of “cluster-hydrogen” and “vacancy-hydrogen” complexes.

  16. Ferromagnetism in cobalt-doped titanium dioxide

    Science.gov (United States)

    Lussier, Alexandre Francois

    Semiconductor spintronics is a promising new field of study in the ongoing quest to make electronic devices faster, cheaper, and more efficient. While current spintronics utilizes the spin property of electrons to achieve greater functionality, the integration of spintronics into conventional semiconductor electronics will lead to advances in opto-electronics, quantum computing, and other emerging fields of technology. This integration relies on effective generation, injection, transport, and detection of spin polarized electron currents. To these ends, the successful synthesis of room temperature ferromagnetic semiconductors is mandatory. In this work, we study the properties of cobalt-doped titanium dioxide, a room temperature dilute ferromagnetic semiconductor discovered in 2001. We characterize the Pulsed Laser Deposition (PLD) of Co-doped TiO2 thin films, including the substrate-induced stabilization of the anatase structure of TiO2. We also confirm the substitutional nature of cobalt on titanium sites by X-ray Absorption Spectroscopy (XAS) techniques. The ferromagnetic interaction mechanism remains controversial. Yet, we provide experimental evidence for the polaron mediated ferromagnetic coupling mechanism recently suggested to mediate ferromagnetic interactions in this, and other magnetically doped oxides, in the dilute regime (approximately 0 to 3%). Our evidence is related to a previously unobserved and unreported XAS spectral feature. Finally, we demonstrate the surprising absence of an X-ray Magnetic Circular Dichroism (XMCD) signature at the cobalt L edge.

  17. Tissue response to implanted ceramic-coated titanium alloys in rats.

    Science.gov (United States)

    Satomi, K; Akagawa, Y; Nikai, H; Tsuru, H

    1988-07-01

    In order to assess the tissue compatibility of the hybrid materials for the dental implant (hydroxyapatite, titanium oxide and titanium nitride coated titanium alloys), tissue response to these materials implanted in the rat subcutaneous tissue was histologically examined. Initial inflammatory response was less evident in titanium oxide coated and non-coated titanium alloys. All materials were encapsulated by thin fibrous connective tissues. The membrane thickness of hydroxyapatite coated titanium alloy was significantly higher than that of titanium nitride coated one. These results suggest that all materials possess favourable tissue compatibility and may encourage clinical use as the dental implant.

  18. Producing Foils From Direct Cast Titanium Alloy Strip

    Science.gov (United States)

    Stuart, T. A.; Gaspar, T. A.; Sukonnik, I. M.; Semiatan, S. L.; Batawi, E.; Peters, J. A.; Fraser, H. L.

    1996-01-01

    This research was undertaken to demonstrate the feasibility of producing high-quality, thin-gage, titanium foil from direct cast titanium strip. Melt Overflow Rapid Solidification Technology (MORST) was used to cast several different titanium alloys into 500 microns thick strip, 10 cm wide and up to 3 m long. The strip was then either ground, hot pack rolled or cold rolled, as appropriate, into foil. Gamma titanium aluminide (TiAl) was cast and ground to approximately 100 microns thick foil and alpha-2 titanium aluminide (Ti3AI) was cast and hot pack rolled to approximately 70 microns thick foil. CP Ti, Ti6Al2Sn4Zr2Mo, and Ti22AI23Nb (Orthorhombic), were successfully cast and cold-rolled into good quality foil (less than 125 microns thick). The foils were generally fully dense with smooth surfaces, had fine, uniform microstructures, and demonstrated mechanical properties equivalent to conventionally produced titanium. By eliminating many manufacturing steps, this technology has the potential to produce thin gage, titanium foil with good engineering properties at significantly reduced cost relative to conventional ingot metallurgy processing.

  19. Temporarily alloying titanium to facilitate friction stir welding

    Energy Technology Data Exchange (ETDEWEB)

    Hovanski, Yuri [Washington State Univ., Pullman, WA (United States)

    2009-05-01

    While historically hydrogen has been considered an impurity in titanium, when used as a temporary alloying agent it promotes beneficial changes to material properties that increase the hot-workability of the metal. This technique known as thermohydrogen processing was used to temporarily alloy hydrogen with commercially pure titanium sheet as a means of facilitating the friction stir welding process. Specific alloying parameters were developed to increase the overall hydrogen content of the titanium sheet ranging from commercially pure to 30 atomic percent. Each sheet was evaluated to determine the effect of the hydrogen content on process loads and tool deformation during the plunge phase of the friction stir welding process. Two materials, H-13 tool steel and pure tungsten, were used to fabricate friction stir welding tools that were plunged into each of the thermohydrogen processed titanium sheets. Tool wear was characterized and variations in machine loads were quantified for each tool material and weld metal combination. Thermohydrogen processing was shown to beneficially lower plunge forces and stabilize machine torques at specific hydrogen concentrations. The resulting effects of hydrogen addition to titanium metal undergoing the friction stir welding process are compared with modifications in titanium properties documented in modern literature. Such comparative analysis is used to explain the variance in resulting process loads as a function of the initial hydrogen concentration of the titanium.

  20. Laser shock peening of titanium 6-4 alloy

    Science.gov (United States)

    Brar, N. S.; Hopkins, A.; Laber, M. W.

    2000-04-01

    Laser shock peening of titanium 6-4 has been shown to improve its high cycle fatigue life. Residual compressive stresses generated on the surface of titanium 6-4, as a result of laser shocking, have shown dramatic improvement in the performance of aircraft turbine blades. Laser shocking of titanium was carried out with a 20 ns pulse width, 50 joule pulsed laser, operated by LSP Technologies, Columbus, OH. Titanium disks, 20-mm in diameter, and ranging in thicknesses from zero (bare LiF) to 3-mm were subjected to laser shock to monitor amplitude and temporal stress profiles of the pulsed laser. Laser shock stress amplitudes on the back of titanium disks were monitored with VISAR using LiF as the window material. The peak shock stress produced in LiF (titanium thickness zero) was measured to be 16±1 GPa. The laser shock amplitude decays to about 2.7 GPa while propagating through 3-mm thick disk of titanium 6-4.

  1. MICROSTRUCTURE AND MECHANICAL PROPERTIES OF CP-TITANIUM (GRADE 4) IMPLANT MATERIALS

    OpenAIRE

    Torun, Gözden

    2015-01-01

    Titanium is came out on top in many areas. A major advantage of titanium alloys from a medical point of view is avoiding chemicophysical reactions, eliminates the danger of a metal allergy so that it is fully biocompatible. Especially, commercially pure titanium is used in medical applications due to its purity. From material scientist point of view, most significant properties of titanium is higher corrosion resistance and the highest strength-to-density ratio. In this manner, titanium alloy...

  2. HOW DOES NIOBIUM IMPROVE THE OXIDATION RESISTANCE OF COMMERCIALLY PURE TITANIUM?

    OpenAIRE

    Ackland, Graeme; Siemers, Carsten; Tegner, Bengt E.; Saksl, K.; Brunke, F.; Kohnke, M,

    2015-01-01

    The application of titanium alloys is limited to 550°C due to their poor oxidation resistance. It is known that the addition of niobium decelerates the oxidation of titanium alloys whereas elements like vanadium do not improve titanium’s oxidation resistance. The underlying mechanisms are not yet well understood. In the present study, different binary titanium-niobium and titanium-vanadium alloys as well as commercially pure titanium were investigated. Oxidation experiments were carried out a...

  3. Recent research and development in titanium alloys for biomedical applications and healthcare goods

    OpenAIRE

    Mitsuo Niinomi

    2003-01-01

    Nb, Ta and Zr are the favorable non-toxic alloying elements for titanium alloys for biomedical applications. Low rigidity titanium alloys composed of non-toxic elements are getting much attention. The advantage of low rigidity titanium alloy for the healing of bone fracture and the remodeling of bone is successfully proved by fracture model made in tibia of rabbit. Ni-free super elastic and shape memory titanium alloys for biomedical applications are energetically developed. Titanium alloys f...

  4. Effect of Titanium Dioxide Treatment on the Properties of 100% Cotton Knitted Fabric

    OpenAIRE

    Md. Mostafizur Rahman; Md. Solaiman; Elias Khalil

    2014-01-01

    Titanium dioxide (TiO2) is a white, water insoluble pigment. It is used in paints, plastics, foods, pharmaceuticals and cosmetics. Its main application on textile materials as an ultraviolet ray protecting agents. Titanium dioxide can reflect, scatter or absorb ultraviolet ray. Besides Titanium dioxide also modify the properties of fabrics. In previous research, titanium dioxide was applied mainly by padding mangle method. This paper presents an approach to observe the effect of titanium d...

  5. Titanium nanotubes stimulate osteoblast differentiation of stem cells from pulp and adipose tissue

    OpenAIRE

    Alfonso Pozio; Annalisa Palmieri; Ambra Girardi; Francesca Cura; Francesco Carinci

    2012-01-01

    Background: Titanium is the gold standard among materials used for prosthetic devices because of its good mechanical and chemical properties. When exposed to oxygen, titanium becomes an oxide, anatase that is biocompatible and able to induce osseointegration. Materials and Methods: In this study we compared the expression profiling of stem cells cultivated on two types of surface: Pure titanium disk and nanotube titanium disk in order to detect if nanotube titanium instead (NTD) surface s...

  6. Optimisation of Sintering Factors of Titanium Foams Using Taguchi Method

    Directory of Open Access Journals (Sweden)

    S. Ahmad

    2010-06-01

    Full Text Available Metal foams have the potential to be used in the production of bipolar plates in Polymer Electron Membrane Fuel Cells (PEMFC. In this paper, pure titanium was used to prepare titanium foam using the slurry method. The electrical conductivity is the most important parameter to be considered in the production of good bipolar plates. To achieve a high conductivity of the titanium foam, the effects of various parameters including temperature, time profile and composition have to be characterised and optimised. This paper reports the use of the Taguchi method in optimising the processing parameters of pure titanium foams. The effects of four sintering factors, namely, composition, sintering temperature, heating rate and soaking time on the electrical conductivity has been studied. The titanium slurry was prepared by mixing titanium alloy powder, polyethylene glycol (PEG, methylcellulose and water. Polyurethane (PU foams were then impregnated into the slurry and later dried at room temperature. These were next sintered in a high temperature vacuum furnace. The various factors were assigned to an L9 orthogonal array. From the Analysis of Variance (ANOVA, the composition of titanium powder has the highest percentage of contribution (24.51 to the electrical conductivity followed by the heating rate (10.29. The optimum electrical conductivity was found to be 1336.227 ± 240.61 S/cm-1 for this titanium foam. It was achieved with a 70% composition of titanium, sintering temperature of 1200oC, a heating rate of 0.5oC/min and 2 hours soaking time. Confirmatory experiments have produced results that lay within the 90% confidence interval.

  7. Surface Functionalization of Orthopedic Titanium Implants with Bone Sialoprotein.

    Directory of Open Access Journals (Sweden)

    Andreas Baranowski

    Full Text Available Orthopedic implant failure due to aseptic loosening and mechanical instability remains a major problem in total joint replacement. Improving osseointegration at the bone-implant interface may reduce micromotion and loosening. Bone sialoprotein (BSP has been shown to enhance bone formation when coated onto titanium femoral implants and in rat calvarial defect models. However, the most appropriate method of BSP coating, the necessary level of BSP coating, and the effect of BSP coating on cell behavior remain largely unknown. In this study, BSP was covalently coupled to titanium surfaces via an aminosilane linker (APTES, and its properties were compared to BSP applied to titanium via physisorption and untreated titanium. Cell functions were examined using primary human osteoblasts (hOBs and L929 mouse fibroblasts. Gene expression of specific bone turnover markers at the RNA level was detected at different intervals. Cell adhesion to titanium surfaces treated with BSP via physisorption was not significantly different from that of untreated titanium at any time point, whereas BSP application via covalent coupling caused reduced cell adhesion during the first few hours in culture. Cell migration was increased on titanium disks that were treated with higher concentrations of BSP solution, independent of the coating method. During the early phases of hOB proliferation, a suppressive effect of BSP was observed independent of its concentration, particularly when BSP was applied to the titanium surface via physisorption. Although alkaline phosphatase activity was reduced in the BSP-coated titanium groups after 4 days in culture, increased calcium deposition was observed after 21 days. In particular, the gene expression level of RUNX2 was upregulated by BSP. The increase in calcium deposition and the stimulation of cell differentiation induced by BSP highlight its potential as a surface modifier that could enhance the osseointegration of orthopedic implants

  8. Improved adherence of sputtered titanium carbide coatings on nickel- and titanium-base alloys

    Science.gov (United States)

    Wheeler, D. R.; Brainard, W. A.

    1979-01-01

    Rene 41 and Ti-6Al-4V alloys were radio frequency sputter coated with titanium carbide by several techniques in order to determine the most effective. Coatings were evaluated in pin-on-disk tests. Surface analysis by X-ray photoelectron spectroscopy was used to relate adherence to interfacial chemistry. For Rene 41, good coating adherence was obtained when a small amount of acetylene was added to the sputtering plasma. The acetylene carburized the alloy surface and resulted in better bonding to the TiC coating. For Ti-6Al-4V, the best adherence and wear protection was obtained when a pure titanium interlayer was used between the coating and the alloy. The interlayer is thought to prevent the formation of a brittle, fracture-prone, aluminum oxide layer.

  9. Rolling-induced Face Centered Cubic Titanium in Hexagonal Close Packed Titanium at Room Temperature

    Science.gov (United States)

    Wu, H. C.; Kumar, A.; Wang, J.; Bi, X. F.; Tomé, C. N.; Zhang, Z.; Mao, S. X.

    2016-04-01

    Combining transmission electron microscopes and density functional theory calculations, we report the nucleation and growth mechanisms of room temperature rolling induced face-centered cubic titanium (fcc-Ti) in polycrystalline hexagonal close packed titanium (hcp-Ti). Fcc-Ti and hcp-Ti take the orientation relation: hcp||fcc and , different from the conventional one. The nucleation of fcc-Ti is accomplished via pure-shuffle mechanism with a minimum stable thickness of three atomic layers, and the growth via shear-shuffle mechanisms through gliding two-layer disconnections or pure-shuffle mechanisms through gliding four-layer disconnections. Such phase transformation offers an additional plastic deformation mode comparable to twinning.

  10. Titania sol-gel coatings with silver on non-porous titanium and titanium alloys

    Science.gov (United States)

    Horkavcova, D.; Cerny, M.; Sanda, L.; Novak, P.; Jablonska, E.; Zlamalova-Cflova, Z.; Helebrant, A.

    2016-04-01

    The objective of the work was to prepare and characterize titania sol-gel coatings on non-porous titanium and newly developed titanium alloys. Basic titania sol contained two forms of silver. Titania sol without silver was used as a reference sample. Coatings were prepared by dip-coating technique during stirring and fired. Coatings after firing were characterized by scanning electron microscopy. All titania coatings were measured to determine their adhesive and bactericidal properties. Adhesion of the coatings to the substrate was measured by tape test. Gram-negative bacteria E. coli was used for the bactericidal test. Coated substrates were immersed into suspension of E. coli in physiological solution for 24 hours. The in vitro cytotoxicity test was performed after one day. The bactericidal effect without toxicity was confirmed for selected coatings.

  11. Laser beam welding of titanium nitride coated titanium using pulse-shaping

    Directory of Open Access Journals (Sweden)

    Milton Sergio Fernandes de Lima

    2005-09-01

    Full Text Available A new welding method which allows the assembly of two titanium nitride coated titanium parts is proposed. The welding procedure utilizes the possibility for pulse-shaping in order to change the energy distribution profile during the laser pulse. The pulse-shaping is composed of three elements: a a short high power pulse for partial ablation at the surface; b a long pulse for thermal penetration; and c a quenching slope for enhanced weldability. The combination of these three elements produces crack-free welds. The weld microstructure is changed in comparison to normal welding, i.e. with a rectangular pulse, as the nitrogen and the microhardness are more homogenously distributed in the weld under pulse-shaping conditions. This laser pulse dissolves the TiN layer and allows nitrogen to diffuse into the melt pool, also contributing to an enhanced weldability by providing suitable thermal conditions.

  12. Thermodynamic equilibrium diagram of the chlorine-titanium system

    Institute of Scientific and Technical Information of China (English)

    DU Ailing; GUO Xiaofei; ZHANG Heming; LIU Jiang

    2005-01-01

    The chemical and electrochemical equilibria of the chlorine-titanium system in the presence of gaseous phase were investigated. Many species, which consisted of chlorine and titanium, were considered. Various thermodynamic equilibria were calculated in the different pressures at different temperatures. The calculated results were shown as log p-1/T and E-T diagrams. These diagrams may be used as important tools for corrosion study and titanium production. The diagrams are also used to thermodynamically determine the existence areas of various species and so on.

  13. Titanium Iodies Mediated Intriguing Transformation of Organic Molecules

    Institute of Scientific and Technical Information of China (English)

    Makoto; SHIMIZU

    2007-01-01

    1 Results Titanium iodides have been found to be good reagents for iodination,reductive formation of enolates,pinacol coupling,and so on.Following new reactions will be discussed:(1) Iodination: Titanium(Ⅳ) iodide is a good iodination reagent for olefins and acetylenes.Simple olefins are iodotitanated with titanium (Ⅳ) iodide to give,after quenching with water,iodoalkanes in moderate to good yields.Phenylacetylene gives α-iodostyrene,whereas 2,2-diiodoalkanes are major products from 1-alkynes when they...

  14. Titanium aluminide intermetallic alloys with improved wear resistance

    Energy Technology Data Exchange (ETDEWEB)

    Qu, Jun; Lin, Hua-Tay; Blau, Peter J.; Sikka, Vinod K.

    2014-07-08

    The invention is directed to a method for producing a titanium aluminide intermetallic alloy composition having an improved wear resistance, the method comprising heating a titanium aluminide intermetallic alloy material in an oxygen-containing environment at a temperature and for a time sufficient to produce a top oxide layer and underlying oxygen-diffused layer, followed by removal of the top oxide layer such that the oxygen-diffused layer is exposed. The invention is also directed to the resulting oxygen-diffused titanium aluminide intermetallic alloy, as well as mechanical components or devices containing the improved alloy composition.

  15. Custom Titanium Ridge Augmentation Matrix (CTRAM): A Case Report.

    Science.gov (United States)

    Connors, Christopher A; Liacouras, Peter C; Grant, Gerald T

    2016-01-01

    This is a case report of a custom titanium ridge augmentation matrix (CTRAM). Using cone beam computed tomography (CBCT), a custom titanium space-maintaining device was developed. Alveolar ridges were virtually augmented, a matrix was virtually designed, and the CTRAM was additively manufactured with titanium (Ti6Al4V). Two cases are presented that resulted in sufficient increased horizontal bone volume with successful dental implant placement. The CTRAM design allows for preoperative planning for increasing alveolar ridge dimensions to support dental implants, reduces surgical time, and prevents the need for a second surgical site to gain sufficient alveolar ridge bone volume for dental implant therapy. PMID:27560675

  16. Effect of sandblasting on fracture load of titanium ceramic crowns

    OpenAIRE

    Moldi, Arvind I.; Bhandari, Kishor Singh; Nagral, Sharanbassapa; Deshpandey, Sumit; Kulkarni, Pawan

    2015-01-01

    Purpose of the Study: It is difficult to achieve a reliable bond between the titanium and veneering porcelain. The aim of this study was to evaluate the bond strength between titanium ceramic crowns. Materials and Methods: The surfaces of titanium copings were divided in two groups. Group A sandblasted with 250 um (n = 10) and Group B without sandblasting (n = 10). Low-fusing porcelain was bonded over copings. A universal testing machine was used to determine the fracture load (N) of the crow...

  17. Local Heating with Lithographically Fabricated Plasmonic Titanium Nitride Nanoparticles

    DEFF Research Database (Denmark)

    Guler, Urcan; Ndukaife, Justus C.; Naik, Gururaj V.;

    2013-01-01

    Titanium nitride is considered a promising alternative plasmonic material and is known to exhibit localized surface plasmon resonances within the near-infrared biological transparency window. Here, local heating efficiencies of disk-shaped nanoparticles made of titanium nitride and gold...... are compared in the visible and near-infrared regions numerically and experimentally with samples fabricated using e-beam lithography. Results show that plasmonic titanium nitride nanodisks are efficient local heat sources and outperform gold nanodisks in the biological transparency window, dispensing the need...

  18. Effects of titanium coating on property of diamond

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The titanium film was coated on the surface of diamond crystal in order to improve the chemical properties of diamond and the effect of titanium coating on the property of diamond was discussed. The anti-impacting strength, the oxidization process and the soakage property between vitrified bond and diamond were investigated. It is found that, when the titanium film is coated on the surface of diamond crystal, the soakage angle between vitrified bond and diamond decreases from 39.5° to 34.5° at 993 K, and the oxidization degree on the surface of diamonds is lowered greatly.

  19. Investigations of Titanium Implants Covered with Hydroxyapatite Layer

    Directory of Open Access Journals (Sweden)

    Świeczko – Żurek B.

    2016-06-01

    Full Text Available To reduce unfavorable phenomena occurring after introducing an implant into human body various modifications of the surface are suggested. Such modifications may have significant impact on biocompatibility of metallic materials. The titanium and it's alloys are commonly used for joint and dental implants due to their high endurance, low plasticity modulus, good corrosion resistance as well as biocompatibility. Special attention should be given to titanium alloys containing zirconium, tantalum and niobium elements. These new generation alloys are used by worldwide engineering specialists. The experiments were performed with hydroxyapatite layer on titanium specimens with the use of electrophoresis method (different voltage and time.

  20. Straightforward synthesis of a novel hydronium titanium oxyfluoride

    International Nuclear Information System (INIS)

    Hydronium titanium oxyfluoride was easily obtained by the thermal decomposition of commercial hexafluorotitanic acid using boric acid as fluoride scavenger. Two synthetic routes were studied: conventional thermal treatment in an oven at 85 deg. C for 20 h and microwave irradiation for 3 min. Powder X-ray and neutron diffraction confirmed that a non-stoichiometric hydronium titanium oxyfluoride isostructural with NH4TiOF3 has been obtained. FT-IR and UV-vis characterization of the as-prepared oxyfluoride is also presented. The hydronium titanium oxyfluoride has prospective applications as a UV-blocking material and solid-phase catalyst.

  1. Computer precision simulation for titanium casting centrifugal mold filling of prescision titanium castings

    OpenAIRE

    Xu, Daming; LI, XIN; Geving AN

    2004-01-01

    Computer simulation codes were developed based on proposed mathematical model for centrifugal mold filling processes and previous computer software for 3D mold filling and solidification of castings. Sample simulations were implemented for mold filling processes of precision titanium castings under gravity and different centrifugal casting techniques. The computation results show that the alloy melt has a much stronger mold filling ability for thin section castings unde a centrifugal force fi...

  2. Electrochemical characterization of cast titanium alloys.

    Science.gov (United States)

    Cai, Zhuo; Shafer, Ty; Watanabe, Ikuya; Nunn, Martha E; Okabe, Toru

    2003-01-01

    A reaction layer forms on cast titanium alloy surfaces due to the reaction of the molten metal with the investment. This surface layer may affect the corrosion of the alloy in the oral environment. The objective of this study was to characterize the in vitro corrosion behavior of cast titanium alloys. ASTM Grade 2 CP titanium, Ti-6Al-4V, Ti-6Al-7Nb and Ti-13Nb-13Zr alloys were cast into a MgO-based investment. Experiments were performed on castings (N=4) with three surface conditions: (A) as-cast surface after sandblasting, (B) polished surface after removal of the reaction layer, and (C) sandblasted surface after removal of the reaction layer. Open-circuit potential (OCP) measurement, linear polarization, and potentiodynamic cathodic polarization were performed in aerated (air+10% CO(2)) modified Tani-Zucchi synthetic saliva at 37 degrees C. Potentiodynamic anodic polarization was subsequently conducted in the same medium deaerated with N(2)+10% CO(2) gas 2 h before and during the experiment. Polarization resistance (R(P)) and corrosion rate (I(CORR)) were calculated. Numerical results were subjected to nonparametric statistical analysis at alpha=0.05. The OCP stabilized for all the specimens after 6 x 10(4)s. Apparent differences in anodic polarization were observed among the different surfaces for all the metals. A passivation region followed by breakdown and repassivation were seen on specimens with surfaces A and C. An extensive passive region was observed on all the metals with surface B. The Kruskal-Wallis test showed no significant differences in OCP, R(p), I(CORR) or break down potential for each of the three surfaces among all the metals. The Mann-Whitney test showed significantly lower R(P) and higher I(CORR) values for surface C compared to the other surfaces. Results indicate that the surface condition has more effect on corrosion of these alloys than the surface reaction layer. Within the oxidation potential range of the oral cavity, all the metal

  3. Formation and characterization of titanium nitride and titanium carbide films prepared by reactive sputtering

    International Nuclear Information System (INIS)

    Titanium has been reactively r.f. sputtered in mixed Ar-N2 and Ar-CH4 discharges on to substrates held at 775 K. The films obtained have been characterized by scanning electron microscopy, X-ray diffraction and by measurements of hardness and electrical resistivity. The compositions of the films have been determined using Auger electron spectroscopy. The processes occurring both on substrates and target surfaces have been studied and it is shown that the latter is of great importance for the composition and structure of deposited films. Titanium nitride films of full density and with electrical resistivity and hardness values close to those of bulk TiN were only obtained in a narrow range close to the stoichiometric composition. Titanium carbide films grown on non-biased substrates were found to have an open structure and thus a low density. A bias applied to the substrate, however, improved the quality of the films. It is also shown that the heat of formation of the compounds plays an important role in the formation of carbides and nitrides. A large value promotes the development of large grains and dense structures. (Auth.)

  4. Bioaccumulation of ionic titanium and titanium dioxide nanoparticles in zebrafish eleutheroembryos.

    Science.gov (United States)

    López-Serrano Oliver, Ana; Muñoz-Olivas, Riansares; Sanz Landaluze, Jon; Rainieri, Sandra; Cámara, Carmen

    2015-01-01

    The production of titanium dioxide nanoparticles (TiO(2) NPs) for commercial applications has greatly increased over the last years and consequently the potential risk for human health. There is a growing awareness of the need to understand the behavior and influence these nanoparticles exert on the environment. Bioaccumulation serves as a good integrator to assess chemical exposure in aquatic systems and is dependent on factors, such as the exposure routes, diet and the aqueous medium. We analyzed the experimental bioaccumulation capability of ionic titanium and TiO(2) NPs by zebrafish (Danio rerio) eleutheroembryos through bioconcentration factors (BCFs), after 48 or 72 h of exposure. The stability of both chemical forms in an aquatic medium was fully characterized for further bioaccumulation studies. Several stabilizing agents (humic acids, soluble starch, polyethylene glycol, Na(4)P(2)O(7) and Na(2)HPO(4)) for anatase and rutile, the two allotrophs of TiO(2) NPs, were evaluated to check the evolution of the aggregation process. Around 60% of TiO(2) NPs remained disaggregated under simulated environmental conditions with the addition of 50 mg L(-1) of humic acids. However, the presence of eleutheroembryos in the exposure medium increased TiO(2) NPs aggregation in the experimental tests. The BCFs values obtained in all cases were <100, which classifies ionic titanium and TiO(2) NPs as non-bioaccumulative substances, under the REACH regulations.

  5. Characterization for rbs of Titanium Oxide thin films grown by Dip Coating in a coloidal suspension of nano structured Titanium Oxide

    International Nuclear Information System (INIS)

    The depth of Titanium Oxide thin films grown by Dip Coating in a coloidal suspension of nano structured Titanium Oxide was characterized using Rutherford Backscattering Spectrometry. Film depths are compared in function of bath and suspension parameters

  6. Breakthrough technologies in titanium refinement methods

    International Nuclear Information System (INIS)

    Recent advances in novel processing approaches for the production of titanium metal have attracted worldwide interest. Affordable methods to replace the Kroll Process for the production of Ti sponge have been sought for decades. In the early 20th century, Al was transformed from a 'precious metal' to a 'commodity' through the development of an efficient electrochemical refinement process. If a similar breakthrough can be devised for Ti, it would find applications in many systems where specific properties are being recognized as enabling; for example advanced armored vehicles, corrosion resistant marine systems as well as the usual aerospace platforms. This presentation will provide an overview of the emerging chemical and molten-salt electrochemical methods being pursued under DARPA sponsorship and the implications for new alloy design. The objectives of these studies will be related to the potential benefits for structural applications in future defense systems

  7. Spark Plasma Sintering of Titanium Spherical Particles

    Science.gov (United States)

    Abedi, Mohammad; Moskovskikh, Dmitry O.; Rogachev, Alexander S.; Mukasyan, Alexander S.

    2016-10-01

    The densification kinetics for sintering of titanium spherical particles under two different experimental schemes, i.e., current-assisted and current-insulated were investigated. It was shown that measurable densification rate differences between the two schemes are recognized only for the preheating stage. For current-assisted experiments, consolidation starts at lower temperatures than for current-insulated samples. Also at high heating rates, the change of sample porosity all through the preheating stage is higher for current-assisted conditions, while at relatively low heating rates ( i.e., less than 100 K/min) they are comparable. All through the isothermal sintering stage, at a temperature of 1073 K (800 °C), the shrinkage rates are comparable for both experimental schemes within the measurement accuracy. The explanation of the observed effects within the framework of conventional sintering theory is also provided.

  8. Combustion of bulk titanium in oxygen

    Science.gov (United States)

    Clark, A. F.; Moulder, J. C.; Runyan, C. C.

    1975-01-01

    The combustion of bulk titanium in one atmosphere oxygen is studied using laser ignition and several analytical techniques. These were high-speed color cinematography, time and space resolved spectra in the visible region, metallography (including SEM) of specimens quenched in argon gas, X-ray and chemical product analyses, and a new optical technique, the Hilbert transform method. The cinematographic application of this technique for visualizing phase objects in the combustion zone is described. The results indicate an initial vapor phase reaction immediately adjacent to the molten surface but as the oxygen uptake progresses the evaporation approaches the point of congruency and a much reduced evaporation rate. This and the accumulation of the various soluble oxides soon drive the reaction zone below the surface where gas formation causes boiling and ejection of particles. The buildup of rutile cuts off the oxygen supply and the reaction ceases.

  9. Isomerization of -carotene by titanium tetrachloride catalyst

    Indian Academy of Sciences (India)

    V Rajendran; B H Chen

    2007-05-01

    Isomerization of all-trans--carotene occurs during shaking with 0.5% of titanium tetrachloride catalyst in methylene chloride at room temperature. In the present study we compared two types of columns C18 and C30 and various solvent systems for the separation of -carotene and its cis isomers by high performance liquid chromatography (HPLC). Results showed that -carotene isomers were resolved by employing a C30 column with a mobile phase of methanol (100%) (A) and methylene chloride (100%) (B) under a gradient elution condition. A total of eleven cis isomers and one all-trans--carotene isomer were resolved within 50 min at a flow rate of 1 ml/min and detection wave-length of 470 nm.

  10. Preparation and integration of nanostructured titanium dioxide

    KAUST Repository

    Zeng, Hua Chun

    2011-10-01

    Titanium dioxide (TiO2) is a chemically stable nontoxic transition-metal oxide associated with a wide range of existing chemical engineering processes. In this short review, recent research endeavors in preparation and integration of nanostructured TiO2 materials system will be featured and discussed for their potential new applications. Because material development always plays pivotal roles in the progress of a particular engineering discipline, the reviewed subjects will provide useful information to stimulate nanoscale research of chemical engineering, linking established fundamentals with practical applications. Some critical issues and challenges regarding further development of this important functional material for nanotechnology will also be addressed. © 2011 Elsevier Ltd. All rights reserved.

  11. Spark Plasma Sintering of Titanium Spherical Particles

    Science.gov (United States)

    Abedi, Mohammad; Moskovskikh, Dmitry O.; Rogachev, Alexander S.; Mukasyan, Alexander S.

    2016-07-01

    The densification kinetics for sintering of titanium spherical particles under two different experimental schemes, i.e., current-assisted and current-insulated were investigated. It was shown that measurable densification rate differences between the two schemes are recognized only for the preheating stage. For current-assisted experiments, consolidation starts at lower temperatures than for current-insulated samples. Also at high heating rates, the change of sample porosity all through the preheating stage is higher for current-assisted conditions, while at relatively low heating rates (i.e., less than 100 K/min) they are comparable. All through the isothermal sintering stage, at a temperature of 1073 K (800 °C), the shrinkage rates are comparable for both experimental schemes within the measurement accuracy. The explanation of the observed effects within the framework of conventional sintering theory is also provided.

  12. In vitro biocompatibility of titanium-nickel alloy with titanium oxide film by H2O2 oxidation

    Institute of Scientific and Technical Information of China (English)

    HU Tao; CHU Cheng-lin; YIN Li-hong; PU Yao-pu; DONG Yin-sheng; GUO Chao; SHENG Xiao-bo; CHUNG Jonathan-CY; CHU Paul-K

    2007-01-01

    Titanium oxide film with a graded interface to NiTi matrix was synthesized in situ on NiTi shape memory alloy(SMA) by oxidation in H2O2 solution. In vitro studies including contact angle measurement, hemolysis, MTT cytotoxicity and cell morphology tests were employed to investigate the biocompatibility of the H2O2-oxidized NiTi SMAs with this titanium oxide film. The results reveal that wettability, blood compatibility and fibroblasts compatibility of NiTi SMA are improved by the coating of titanium oxide film through H2O2 oxidation treatment.

  13. Chemical rate model for the surface pyrolysis of tetrakis(dimethylamido)titanium to form titanium nitride films

    Science.gov (United States)

    Toprac, Anthony J.; Iacoponi, John A.; Littau, Karl A.

    1998-09-01

    A chemical kinetic rate model for the deposition of titanium nitride films from the surface reaction of tetrakis(dimethyl-amido)titanium (TDMAT) was developed. Without ammonia addition, TDMAT forms a titanium nitride film by pyrolyzing on the hot substrate surface. Experimental data from the applied materials 5000 deposition tool was modeled using a CSTR formulation. With the parameters of the surface reaction model regressed to fit portions of the experimental results, reasonably accurate model predictions over the entire domain of experimental data were obtained.

  14. Bacterial adherence to anodized titanium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Peremarch, C Perez-Jorge; Tanoira, R Perez; Arenas, M A; Matykina, E; Conde, A; De Damborenea, J J; Gomez Barrena, E; Esteban, J, E-mail: cperemarch@fjd.es

    2010-11-01

    The aim of this study was to evaluate Staphylococcus sp adhesion to modified surfaces of anodized titanium alloy (Ti-6Al-4V). Surface modification involved generation of fluoride-containing titanium oxide nanotube films. Specimens of Ti-6Al-4V alloy 6-4 ELI-grade 23- meets the requirements of ASTM F136 2002A (AMS 2631B class A1) were anodized in a mixture of sulphuric/hydrofluoric acid at 20 V for 5 and 60 min to form a 100 nm-thick porous film of 20 nm pore diameter and 230 nm-thick nanotube films of 100 nm in diameter. The amount of fluorine in the oxide films was of 6% and of 4%, respectively. Collection strains and six clinical strains each of Staphylococcus aureus and Staphylococcus epidermidis were studied. The adherence study was performed using a previously published protocol by Kinnari et al. The experiments were performed in triplicates. As a result, lower adherence was detected for collection strains in modified materials than in unmodified controls. Differences between clinical strains were detected for both species (p<0.0001, Kruskal-Wallis test), although global data showed similar results to that of collection strains (p<0.0001, Kruskal-Wallis test). Adherence of bacteria to modified surfaces was decreased for both species. The results also reflect a difference in the adherence between S. aureus and S. epidermidis to the modified material. As a conclusion, not only we were able to confirm the decrease of adherence in the modified surface, but also the need to test multiple clinical strains to obtain more realistic microbiological results due to intraspecies differences.

  15. Plasma electrolytic oxidation of Titanium Aluminides

    Science.gov (United States)

    Morgenstern, R.; Sieber, M.; Grund, T.; Lampke, T.; Wielage, B.

    2016-03-01

    Due to their outstanding specific mechanical and high-temperature properties, titanium aluminides exhibit a high potential for lightweight components exposed to high temperatures. However, their application is limited through their low wear resistance and the increasing high-temperature oxidation starting from about 750 °C. By the use of oxide ceramic coatings, these constraints can be set aside and the possible applications of titanium aluminides can be extended. The plasma electrolytic oxidation (PEO) represents a process for the generation of oxide ceramic conversion coatings with high thickness. The current work aims at the clarification of different electrolyte components’ influences on the oxide layer evolution on alloy TNM-B1 (Ti43.5Al4Nb1Mo0.1B) and the creation of compact and wear resistant coatings. Model experiments were applied using a ramp-wise increase of the anodic potential in order to show the influence of electrolyte components on the discharge initiation and the early stage of the oxide layer growth. The production of PEO layers with technically relevant thicknesses close to 100 μm was conducted in alkaline electrolytes with varying amounts of Na2SiO3·5H2O and K4P2O7 under symmetrically pulsed current conditions. Coating properties were evaluated with regard to morphology, chemical composition, hardness and wear resistance. The addition of phosphates and silicates leads to an increasing substrate passivation and the growth of compact oxide layers with higher thicknesses. Optimal electrolyte compositions for maximum coating hardness and thickness were identified by statistical analysis. Under these conditions, a homogeneous inner layer with low porosity can be achieved. The frictional wear behavior of the compact coating layer is superior to a hard anodized layer on aluminum.

  16. Waterless TiO{sub 2} atomic layer deposition using titanium tetrachloride and titanium tetraisopropoxide

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Virginia R.; Cavanagh, Andrew S.; Abdulagatov, Aziz I. [Department of Chemistry and Biochemistry, University of Colorado, Boulder, Colorado 80309-0215 (United States); Gibbs, Zachary M. [Department of Chemical and Biological Engineering, University of Colorado, Boulder, Colorado 80309-0424 (United States); George, Steven M., E-mail: Steven.George@Colorado.Edu [Department of Chemistry and Biochemistry, University of Colorado, Boulder, Colorado 80309-0215 and Department of Mechanical Engineering, University of Colorado, Boulder, Colorado 80309-0427. (United States)

    2014-01-15

    The surface chemistry for TiO{sub 2} atomic layer deposition (ALD) typically utilizes water or other oxidants that can oxidize underlying substrates such as magnetic disks or semiconductors. To avoid this oxidation, waterless or oxidant-free surface chemistry can be used that involves titanium halides and titanium alkoxides. In this study, waterless TiO{sub 2} ALD was accomplished using titanium tetrachloride (TiCl{sub 4}) and titanium tetraisopropoxide (TTIP). In situ transmission Fourier transform infrared (FTIR) studies were employed to study the surface species and the reactions during waterless TiO{sub 2} ALD. At low temperatures between 125 and 225  °C, the FTIR absorbance spectra revealed that the isopropoxide species remained on the surface after TTIP exposures. The TiCl{sub 4} exposures then removed the isopropoxide species and deposited additional titanium species. At high temperatures between 250 and 300  °C, the isopropoxide species were converted to hydroxyl species by β-hydride elimination. The observation of propene gaseous reaction product by quadrupole mass spectrometry (QMS) confirmed the β-hydride elimination reaction pathway. The TiCl{sub 4} exposures then easily reacted with the hydroxyl species. QMS studies also observed the 2-chloropropane and HCl gaseous reaction products and monitored the self-limiting nature of the TTIP reaction. Additional studies examined the waterless TiO{sub 2} ALD growth at low and high temperature. Quartz crystal microbalance measurements observed growth rates of ∼3 ng/cm{sup 2} at a low temperature of 150  °C. Much higher growth rates of ∼15 ng/cm{sup 2} were measured at a higher temperature of 250  °C under similar reaction conditions. X-ray reflectivity analysis measured a growth rate of 0.55 ± 0.05 Å/cycle at 250  °C. X-ray photoelectron depth-profile studies showed that the TiO{sub 2} films contained low Cl concentrations <1 at. %. This waterless TiO{sub 2} ALD process

  17. An Insoluble Titanium-Lead Anode for Sulfate Electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Ferdman, Alla

    2005-05-11

    The project is devoted to the development of novel insoluble anodes for copper electrowinning and electrolytic manganese dioxide (EMD) production. The anodes are made of titanium-lead composite material produced by techniques of powder metallurgy, compaction of titanium powder, sintering and subsequent lead infiltration. The titanium-lead anode combines beneficial electrochemical behavior of a lead anode with high mechanical properties and corrosion resistance of a titanium anode. In the titanium-lead anode, the titanium stabilizes the lead, preventing it from spalling, and the lead sheathes the titanium, protecting it from passivation. Interconnections between manufacturing process, structure, composition and properties of the titanium-lead composite material were investigated. The material containing 20-30 vol.% of lead had optimal combination of mechanical and electrochemical properties. Optimal process parameters to manufacture the anodes were identified. Prototypes having optimized composition and structure were produced for testing in operating conditions of copper electrowinning and EMD production. Bench-scale, mini-pilot scale and pilot scale tests were performed. The test anodes were of both a plate design and a flow-through cylindrical design. The cylindrical anodes were composed of cylinders containing titanium inner rods and fitting over titanium-lead bushings. The cylindrical design allows the electrolyte to flow through the anode, which enhances diffusion of the electrolyte reactants. The cylindrical anodes demonstrate higher mass transport capabilities and increased electrical efficiency compared to the plate anodes. Copper electrowinning represents the primary target market for the titanium-lead anode. A full-size cylindrical anode performance in copper electrowinning conditions was monitored over a year. The test anode to cathode voltage was stable in the 1.8 to 2.0 volt range. Copper cathode morphology was very smooth and uniform. There was no

  18. Copper and nickel adherently electroplated on titanium alloy

    Science.gov (United States)

    Brown, E. E.

    1967-01-01

    Anodic treatment of titanium alloy enables electroplating of tightly adherent coatings of copper and nickel on the alloy. The alloy is treated in a solution of hydrofluoric and acetic acids, followed by the electroplating process.

  19. Measurement of Thermodynamic Properties of Titanium Aluminum Alloys

    Science.gov (United States)

    Mehrotra, Gopal

    1995-01-01

    This final report is a summary of the work done by Professor Mehrotra at NASA Lewis Research Center. He has worked extensively on the measurement of thermodynamic properties of titanium aluminum alloys over the past six years.

  20. Ion beam mixing of titanium overlayers with hydroxyapaptite substrates

    Energy Technology Data Exchange (ETDEWEB)

    Levine, T.E. [Cornell Univ., Ithaca, NY (United States). Dept. of Materials Science and Engineering; Nastasi, M. [Los Alamos National Lab., NM (United States); Alford, T.L.; Suchicital, C.; Russell, S.; Luptak, K.; Pizziconi, V.; Mayer, J.W. [Arizona State Univ., Tempe, AZ (United States)

    1995-01-01

    The mixing of titanium overlayers with hydroxyapatite (HA) substrates via ion irradiation has been demonstrated. Analysis via secondary ion mass spectroscopy (SIMS) indicates an interfacial broadening of titanium and calcium of the implanted sample compared to that of the unimplanted sample. Attendant to the observed ion beam mixing of titanium into the HA, the oxygen signal of the titanium overlayer increases as a result of ion irradiation. It is supposed that this change is evident of diffusion through the metal layer and possibly from titania formation at the free surface and perovskite formation at the film/substrate interface. This possibility is consistent with thermodynamic predictions. Additionally, the force required to separate the film from the substrate increased as a result of ion irradiation, validating the continued study of ion beam processing of Ti/HA systems towards the improvement of long term fixation of implant devices.

  1. An Oxidation-Resistant Coating Alloy for Gamma Titanium Aluminides

    Science.gov (United States)

    Brady, Michael P.; Smialek, James L.; Brindley, William J.

    1997-01-01

    Titanium aluminides based on the g-phase (TiAl) offer the potential for component weight savings of up to 50 percent over conventional superalloys in 600 to 850 C aerospace applications. Extensive development efforts over the past 10 years have led to the identification of "engineering" gamma-alloys, which offer a balance of room-temperature mechanical properties and high-temperature strength retention. The gamma class of titanium aluminides also offers oxidation and interstitial (oxygen and nitrogen) embrittlement resistance superior to that of the alpha(sub 2) (Ti3Al) and orthorhombic (Ti2AlNb) classes of titanium aluminides. However, environmental durability is still a concern, especially at temperatures above 750 to 800 C. Recent work at the NASA Lewis Research Center led to the development of an oxidation-resistant coating alloy that shows great promise for the protection of gamma titanium aluminides.

  2. Porous titanium implants fabricated by metal injection molding

    Institute of Scientific and Technical Information of China (English)

    CHEN Liang-jian; LI Ting; LI Yi-min; HE Hao; HU You-hua

    2009-01-01

    Sodium chloride (NaCl) was added as a space holder in synthesis of porous titanium by using metal injection molding(MIM) method. The microstructure and mechanical properties of porous titanium were analyzed by mercury porosimeter, scanning electron microscope(SEM) and compression tester. The results show that the content of NaCl influences the porosity of porous titanium significantly. Porous titanium powders with porosity in the range of 42.4%-71.6% and pore size up to 300 μm were fabricated. The mechanical test shows that with increasing NaCl content, the compressive strength decreases from 316.6 to 17.5 MPa and the elastic modulus decreases from 3.03 to 0.28 GPa.

  3. Study on Crystallization of Titanium Silicalite Zeolite (Ⅱ)

    Institute of Scientific and Technical Information of China (English)

    Lin Min; Zhu Bin; Shu Xingtian; Wang Xieqing

    2009-01-01

    In order to investigate the rules on formation of zeolite during crystallization of titanium silicalite zeolite (TS-1) the X-ray diffractometry and Foulier transform infra-red spectrometry were applied to track the process of crystallization of titanium silicalite zeolite. The research results revealed that at the initial stage of crystallization the interactions between silica gel and titania gel in the polymer blend could gradually lead to the formation of tiny crystal nuclei with complicated structure that could slowly grow up to form molecular sieves. Quite different from the conventional zeolites that use the acid sites as the catalytically active centers, the oxidative reactivity of the titanium silicalite zeolite was not proportional to its crystallinity and is associated with the oxidative centers of titanium contained in the zeolite.

  4. Novel titanium-aluminum joints for cryogenic cold finger structures

    Science.gov (United States)

    Meehan, H. M.; Sweet, R. C.

    For optimum performance, the sensors employed in airborne detection and surveillance systems must be maintained at low temperatures. The containing wall of the expansion volume of a Stirling cycle cooler may provide the low temperature surface for mounting the sensors. IR detectors are commonly mounted on copper heat exchanger surfaces. A stainless steel member is employed to thermally isolate and structurally stabilize such surfaces. It is pointed out that the use of an aluminum-titanium cold finger results in a considerable weight reduction. The present investigation is concerned with an attempt to obtain such structures with the aid of a technique involving the casting of molten aluminum onto an appropriately dimensioned and positioned titanium member, taking into account the fact that aluminum readily wets and bonds to clean titanium surfaces. The casting is then machined to provide the form and structure desired. It is concluded that aluminum-titanium cast structures offer good potential for use as cryogenic cold finger assemblies.

  5. Surface Modifications and Their Effects on Titanium Dental Implants

    Directory of Open Access Journals (Sweden)

    A. Jemat

    2015-01-01

    Full Text Available This review covers several basic methodologies of surface treatment and their effects on titanium (Ti implants. The importance of each treatment and its effects will be discussed in detail in order to compare their effectiveness in promoting osseointegration. Published literature for the last 18 years was selected with the use of keywords like titanium dental implant, surface roughness, coating, and osseointegration. Significant surface roughness played an important role in providing effective surface for bone implant contact, cell proliferation, and removal torque, despite having good mechanical properties. Overall, published studies indicated that an acid etched surface-modified and a coating application on commercial pure titanium implant was most preferable in producing the good surface roughness. Thus, a combination of a good surface roughness and mechanical properties of titanium could lead to successful dental implants.

  6. Surface Modifications and Their Effects on Titanium Dental Implants.

    Science.gov (United States)

    Jemat, A; Ghazali, M J; Razali, M; Otsuka, Y

    2015-01-01

    This review covers several basic methodologies of surface treatment and their effects on titanium (Ti) implants. The importance of each treatment and its effects will be discussed in detail in order to compare their effectiveness in promoting osseointegration. Published literature for the last 18 years was selected with the use of keywords like titanium dental implant, surface roughness, coating, and osseointegration. Significant surface roughness played an important role in providing effective surface for bone implant contact, cell proliferation, and removal torque, despite having good mechanical properties. Overall, published studies indicated that an acid etched surface-modified and a coating application on commercial pure titanium implant was most preferable in producing the good surface roughness. Thus, a combination of a good surface roughness and mechanical properties of titanium could lead to successful dental implants.

  7. Manufacturing Technology and Application Trends of Titanium Clad Steel Plates

    Institute of Scientific and Technical Information of China (English)

    Hang SU; Xiao-bing LUO; Feng CHAI; Jun-chang SHEN; Xin-jun SUN; Feng LU

    2015-01-01

    Some of the major manufacturing processes and corresponding mechanical properties of titanium clad steel plates were analyzed, and the consequences of research, manufacturing, and application of titanium clad steel plates in both markets of China and overseas were also summarized. As an economical and environmentally friendly technology, the roll bonding process is ex-pected to become the next-generation mainstream process for the manufacturing of titanium clad steel plate. Some of the crucial and most important technical problems of this particular process, including vacuum sealing technology, surface treatment process technology, application of a transition layer, and rolling process, were discussed along with the advantageous mechanical properties and life-cycle economy of these plates processed by this technology. Finally, the market needs, application trends, and requirements of titanium clad steel plate were also considered from industries of petrochemical, shipbuilding, marine, and electric power.

  8. Characterization of titanium coatings obtained by plasma jet deposition

    International Nuclear Information System (INIS)

    By injecting titanium chloride (TiCl4) into a low pressure argon arc plasma, thin titanium layers have been obtained on stainless steel substrate. The surface topography of the coatings was observed by scanning electron microscopy. The influence of the distance between the TiCl4 injection and the substrate has been investigated, and, for different deposition parameters, droplets can be observed on the surface of the samples. The chemical composition of the titanium films was determined with energy dispersive spectrometry (EDAX). Chemical analysis of the coatings allows to show the presence of titanium and chlorine. The percentage of impurities (i.e. chlorine) seems to depend strongly on the experimental conditions. (author). 3 refs., 2 figs., 1 tab., 1 photo

  9. One half of a prototype titanium vacuum chamber

    CERN Multimedia

    CERN PhotoLab

    1973-01-01

    Designed and constructed in the ISR Department, it could be for general use at intersection regions. The use of titanium instead of stainless steel increases the "transparency" to particles by a factor of about two for the same wall thickness.

  10. Synthesis of titanium carbide by induction plasma reactive spray

    Institute of Scientific and Technical Information of China (English)

    JIANG Xian-Liang(蒋显亮); M.Boulos

    2004-01-01

    A novel method capable of sufficient mixing of titanium powder and methane of carbon source was developed in the synthesis of titanium carbide by induction plasma reactive spray. X-ray diffraction analysis, optical microscopy, scanning electron microscopy, and microhardness test were used to characterize the spray-formed deposit.The experimental results show that both primary carburization of the titanium particles inside the plasma flame and secondary carburization of the growing deposit on high temperature substrate contribute to the forming of titanium carbide. The transitional phase of TiC1-x has the same crystal structure as TiC, but has a slightly low lattice constant. The deposit consists of fine grain structure and large grain structure. The fine grain structure, harder than large grain structure, shows grain boundary fracture.

  11. [Subantral augmentation with porous titanium in experiment and clinic].

    Science.gov (United States)

    Sirak, S V; Shchetinin, E V; Sletov, A A

    2016-01-01

    The article discusses the use of porous titanium for subantral augmentation. Experimental study was conducted on 12 yearling rams. Subantral augmentation using porous titanium was performed in 33 patients. In the control group consisting of 14 patients calcium phosphates and bone collagen based agents ("Bio-Оss" and "Collost") were used. In the main and control groups 46 and 32 implant were placed, respectively. Pilot histological and clinical studies proved that the granules of porous titanium are biocompatible with bone tissue, provide the optimal surface microrelief, thus creating good conditions for adhesion, expansion and migration of osteoforming cells, have negligible kinetics of resorption, are porous to ensure effective neovascularization of de novo formed bone tissue. Porous titanium is an effective alternative material for subantral bone augmentation for dental implantation and reconstructive operations on the maxillary sinus.

  12. Titanium Loop Heat Pipes for Space Nuclear Radiators Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will develop titanium Loop Heat Pipes (LHPs) that can be used in low-mass space nuclear radiators, such as...

  13. Carbamazepine degradation by photolysis and titanium dioxide photocatalysis.

    Science.gov (United States)

    Im, Jong-Kwon; Son, Hyun-Seok; Kang, Young-Min; Zoh, Kyung-Duk

    2012-07-01

    We investigated the degradation of carbamazepine by photolysis/ultraviolet (UV)-C only and titanium dioxide photocatalysis. The degradation of carbamazepine by UV-only and titanium-dioxide-only (adsorption) reactions were inefficient, however, complete degradation of carbamazepine was observed by titanium dioxide photocatalysis within 30 min. The rate of degradation increased as initial carbamazepine concentration decreased, and the removal kinetics fit well with the Langmuir-Hinshelwood model. The addition of methanol, a radical scavenger, decreased carbamazepine removal, suggesting that the hydroxide radical played an important role during carbamazepine degradation. The addition of oxygen during titanium dioxide photocatalysis accelerated hydroxide radical production, thus improving mineralization activity. The photocatalytic degradation was more efficient at a higher pH, whereas the removal of carbamazepine and acridine (a major intermediate) were more efficient under aerobic conditions. The mineralization of carbamazepine during photocatalysis produced various ionic by-products such as ammonium and nitrate by way of nitrogen dioxide.

  14. Preparation and characterization of nitrogen-doped titanium dioxides

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    A type of high visible-light active titanium oxinitride(TiO2-xNx) powder was prepared by a simple proc-ess:the calcination of the hydrated titanium dioxide at the atmosphere of ammonia-argon using a tu-bular electric furnace at high temperatures. The hydrated titanium dioxide was synthesized as the precursor of TiO2-xNx using titanic acid as raw material,which came from sulfate technique of produc-ing titanium white. The effects of temperature and reaction time on the nitrogen content,grain size and crystal structure were studied. The visible-light activity and photocatalysis capability of the powder were also investigated.

  15. Twinning induced plasticity in commercially pure titanium at low temperature

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Using Instron 1342 at a displacement rate of 0.5  mm/min, tensile tests were conducted in hot-rolled and annealed commercial pure titanium at room temperature and 77  K, respectively. Fracture surfaces and microstructures after tests were investigated by SEM and TEM respectively. The results show that both the strength and the ductility of titanium at 77  K are higher than those at room temperature. The main deformation mode of pure titanium changes from slipping at room temperature to twinning at 77  K. Twinning induced plasticity is put forward to interpret the abnormal high ductility of titanium at low temperature of 77  K.

  16. [Subantral augmentation with porous titanium in experiment and clinic].

    Science.gov (United States)

    Sirak, S V; Shchetinin, E V; Sletov, A A

    2016-01-01

    The article discusses the use of porous titanium for subantral augmentation. Experimental study was conducted on 12 yearling rams. Subantral augmentation using porous titanium was performed in 33 patients. In the control group consisting of 14 patients calcium phosphates and bone collagen based agents ("Bio-Оss" and "Collost") were used. In the main and control groups 46 and 32 implant were placed, respectively. Pilot histological and clinical studies proved that the granules of porous titanium are biocompatible with bone tissue, provide the optimal surface microrelief, thus creating good conditions for adhesion, expansion and migration of osteoforming cells, have negligible kinetics of resorption, are porous to ensure effective neovascularization of de novo formed bone tissue. Porous titanium is an effective alternative material for subantral bone augmentation for dental implantation and reconstructive operations on the maxillary sinus. PMID:26925568

  17. Green oxidations: Titanium dioxide induced tandem oxidation coupling reactions

    OpenAIRE

    Vineet Jeena; Robinson, Ross S.

    2009-01-01

    The application of titanium dioxide as an oxidant in tandem oxidation type processes is described. Under microwave irradiation, quinoxalines have been synthesized in good yields from the corresponding α-hydroxyketones.

  18. Lunar-derived titanium alloys for hydrogen storage

    Science.gov (United States)

    Love, S.; Hertzberg, A.; Woodcock, G.

    1992-01-01

    Hydrogen gas, which plays an important role in many projected lunar power systems and industrial processes, can be stored in metallic titanium and in certain titanium alloys as an interstitial hydride compound. Storing and retrieving hydrogen with titanium-iron alloy requires substantially less energy investment than storage by liquefaction. Metal hydride storage systems can be designed to operate at a wide range of temperatures and pressures. A few such systems have been developed for terrestrial applications. A drawback of metal hydride storage for lunar applications is the system's large mass per mole of hydrogen stored, which rules out transporting it from earth. The transportation problem can be solved by using native lunar materials, which are rich in titanium and iron.

  19. Ultrasonic Surface Treatment of Titanium Alloys. The Submicrocrystalline State

    OpenAIRE

    Klimenov, Vasily Aleksandrovich; Vlasov, V.A.; Borozna, Vyacheslav Yurievich; Klopotov, A. A.

    2015-01-01

    The paper presents the results of the research on improvement of physical-and mechanical properties of titanium alloys VT1-0 and VT6 by modification of surfaces using ultrasonic treatment, and a comprehensive study of the microstructure and mechanical properties of modified surface layers. It has been established that exposure to ultrasonic treatment leads to formation in the surface layer of a structure with an average size of elements 50 x100 nm, depending on the brand of titanium alloy.

  20. The Sustainable Improvement of Manufacturing for Nano-Titanium

    OpenAIRE

    Chia-Nan Wang; Han-Sung Lin; Ming-Hsien Hsueh; Yen-Hui Wang; Thi-Hao Vu; Tsung-Fu Lin

    2016-01-01

    Scientists have found that nanomaterials possess many outstanding features in their tiny grain structure compared to other common materials. Titanium at the nano-grain scale shows many novel characteristics which demonstrate suitability for use in surgical implants. In general, equal channel angular pressing (ECAP) is the most popular and simple process to produce nano-titanium. However, ECAP is time-consuming, power-wasting, and insufficiently produces the ultrafine grain structure. Therefor...

  1. Titanium zirconium and hafnium coordination compounds with vanillin thiosemicarbazone

    International Nuclear Information System (INIS)

    Coordination compounds of titanium zirconium and hafnium tetrachlorides with vanillin thiosemicarbazone of MCl4 x nLig composition, where n=1.5, 4 for titanium and 1, 2, 4 for zirconium and hafnium, are synthesized. Molar conductivity of ethanol solutions is measured; IR spectroscopic and thermochemical investigation are carried out. The supposition about ligand coordination via sulfur and azomethine nitrogen atoms is made. In all cases hafnium forms stable compounds than zirconium

  2. Study on the preparation and properties of potassium titanium hexacyanoferrate

    International Nuclear Information System (INIS)

    A method of preparing a new inorganic ion exchanger named potassium titanium hexacyanoferrate by sol-gel technology is investigated. The composition and structure of the exchanger are tested and its exchange properties are studied. The results show that the surfactant content in dispersing medium and stirring speed affect greatly the preparation of titanium dioxide. Immersing and drying conditions affect greatly the exchange capacity and speed for Cs+. Excellent inorganic exchanger has been prepared

  3. Spectroscopic and ultrastructural analysis of fluorhydroxyapatite-coated titanium plates

    Energy Technology Data Exchange (ETDEWEB)

    Martini, D.; Ottani, V.; Ruggeri, A. [Bologna Univ. (Italy). Dipt. di Scienze Anatomiche e Fisiopatologia dell' Apparato Locomotore; Raspanti, M. [Insubria Univ. (Italy). Dipt. di Scienze Cliniche e Biologiche; Monti, P.; Taddei, P.; Tinti, A.; Fragnano, C. [Bologna Univ. (Italy). Dipt. di Biochimica ' G. Moruzzi'

    2001-07-01

    This study aimed to describe the chemical, physical and morphological features of the surface of titanium plates coated with porous titanium and fluorhydroxyapatite for surgical implantation. Although the plasma flame spray coating process partially altered the original chemical and physical characteristics of the coatings, the surface morphology of the coated plates seems very favourable for bone integration of the implant. Immersion in simulated body fluid for ten weeks failed to disclose signs of implant dissolution or impaired surface composition. (orig.)

  4. Trial manufacturing of titanium-carbon steel composite overpack

    Energy Technology Data Exchange (ETDEWEB)

    Honma, Nobuyuki; Chiba, Takahiko; Tanai, Kenji [Japan Nuclear Cycle Development Inst., Waste Management and Fuel Cycle Research Center, Tokai, Ibaraki (Japan)

    1999-11-01

    This paper reports the results of design analysis and trial manufacturing of full-scale titanium-carbon steel composite overpacks. The overpack is one of the key components of the engineered barrier system, hence, it is necessary to confirm the applicability of current technique in their manufacture. The required thickness was calculated according to mechanical resistance analysis, based on models used in current nuclear facilities. The Adequacy of the calculated dimensions was confirmed by finite-element methods. To investigate the necessity of a radiation shielding function of the overpack, the irradiation from vitrified waste has been calculated. As a result, it was shown that shielding on handling and transport equipment is a more reasonable and practical approach than to increase thickness of overpack to attain a self-shielding capability. After the above investigation, trial manufacturing of full-scale model of titanium-carbon steel composite overpack has been carried out. For corrosion-resistant material, ASTM Grade-2 titanium was selected. The titanium layer was bonded individually to a cylindrical shell and fiat cover plates (top and bottom) made of carbon steel. For the cylindrical shell portion, a cylindrically formed titanium layer was fitted to the inner carbon steel vessel by shrinkage. For the flat cover plates (top and bottom), titanium plate material was coated by explosive bonding. Electron beam welding and gas metal arc welding were combined to weld of the cover plates to the body. No significant failure was evident from inspections of the fabrication process, and the applicability of current technology for manufacturing titanium-carbon steel composite overpack was confirmed. Future research and development items regarding titanium-carbon steel composite overpacks are also discussed. (author)

  5. Electrodeposition of niobium and titanium in molten salts

    International Nuclear Information System (INIS)

    The electrodeposition of niobium and titanium in molten fluorides from the additions of fluorine niobates and fluorine titanates of potassium is described in laboratory and pilot scale. The temperature influence, the current density and the time deposition over the current efficiency, the deposits structure and the deposits purity are studied. The conditions for niobium coating over copper and carbon steel and for titanium coating over carbon steel are also presented. (C.G.C.)

  6. Grafting titanium nitride surfaces with sodium styrene sulfonate thin films

    OpenAIRE

    Zorn, Gilad; MIGONNEY, Véronique; Castner, David G.

    2014-01-01

    The importance of titanium nitride lies in its high hardness and its remarkable resistance to wear and corrosion, which has led to its use as a coating for the heads of hip prostheses, dental implants and dental surgery tools. However, the usefulness of titanium nitride coatings for biomedical applications could be significantly enhanced by modifying their surface with a bioactive polymer film. The main focus of the present work was to graft a bioactive poly(sodium styrene sulf...

  7. Immobilizing hydroxycholesterol with apatite on titanium surfaces to induce ossification

    OpenAIRE

    Chen, Cen; Yang, Hyeong Cheol; Lee, In-Seop

    2014-01-01

    Background Immobilizing bioactive molecules and osteoconductive apatite on titanium implants have investigated direct ossification. In this study, hydroxycholesterol (HC) was immobilized with apatite on titanium through simply adsorption or sandwich-like coating. Three kinds of hydroxycholesterol were chosen to induce ossification: 20α-hydroxycholesterol (20α- HC), 22(S)-hydroxycholesterol (22(S)-HC) and 25-hydroxycholesterol (25-HC).The effects of HC/apatite coating on ossification abilities...

  8. Hydroxyapatite electrodeposition on anodized titanium nanotubes for orthopedic applications

    Energy Technology Data Exchange (ETDEWEB)

    Parcharoen, Yardnapar [Department of Biological Engineering, Faculty of Engineering, King Mongkut' s University of Technology Thonburi, Bangkok (Thailand); Kajitvichyanukul, Puangrat [Center of Excellence on Environmental Research and Innovation, Faculty of Engineering, Naresuan University, Phitsanulok (Thailand); Sirivisoot, Sirinrath [Department of Biological Engineering, Faculty of Engineering, King Mongkut' s University of Technology Thonburi, Bangkok (Thailand); Termsuksawad, Preecha, E-mail: preecha.ter@kmutt.ac.th [Division of Materials Technology, School of Energy, Environment and Materials, King Mongkut' s University of Technology Thonburi, 126 Pracha Uthit Rd., Bang Mod, ThungKhru, Bangkok 10140 (Thailand)

    2014-08-30

    Highlights: • We found that different anodization time of titanium significantly effects on nanotube length which further impacts adhesion strength of hydroxyapatite coating layers. • Adhesion strength of Hydroxyapatite (HA) coated on titanium dioxide nanotubes is better than that of HA coated on titanium plate. • Hydroxyapatite coated on titanium dioxide nanotubes showed higher cell density and better spreading of MC3T3-E1 cells (bone-forming cells) than that coated on titanium plate surface. - Abstract: Nanotubes modification for orthopedic implants has shown interesting biological performances (such as improving cell adhesion, cell differentiation, and enhancing osseointegration). The purpose of this study is to investigate effect of titanium dioxide (TiO{sub 2}) nanotube feature on performance of hydroxyapatite-coated titanium (Ti) bone implants. TiO{sub 2} nanotubes were prepared by anodization using ammonium fluoride electrolyte (NH{sub 4}F) with and without modifiers (PEG400 and Glycerol) at various potential forms, and times. After anodization, the nanotubes were subsequently annealed. TiO{sub 2} nanotubes were characterized by scanning electron microscope and X-ray diffractometer. The amorphous to anatase transformation due to annealing was observed. Smooth and highly organized TiO{sub 2} nanotubes were found when high viscous electrolyte, NH{sub 4}F in glycerol, was used. Negative voltage (−4 V) during anodization was confirmed to increase nanotube thickness. Length of the TiO{sub 2} nanotubes was significantly increased by times. The TiO{sub 2} nanotube was electrodeposited with hydroxyapatite (HA) and its adhesion was estimated by adhesive tape test. The result showed that nanotubes with the tube length of 560 nm showed excellent adhesion. The coated HA were tested for biological test by live/dead cell straining. HA coated on TiO{sub 2} nanotubes showed higher cells density, higher live cells, and more spreading of MC3T3-E1 cells than that

  9. Characterisation of hydroxyapatite-coated titanium for biomedical applications

    OpenAIRE

    Lee, Jiin Woei

    2014-01-01

    Orthopaedic implants function to replace or support damaged or diseased bone. Due to a global rise in demand, there is a need to prolong the service life of these implants. The current work focuses on crystallised hydroxyapatite (HA)-coated titanium (Ti) implants. One specific problem during the annealing of as-deposited amorphous HA, to induce crystallisation, is the formation of unwanted titanium oxide (Ti-O) species at the HA/Ti interface that leads to HA layer disruption. This necessitate...

  10. Characterization of Hydroxyapatite Film on Titanium Substrate by Sputtering Technique

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Radiofrequent magnetron sputtering technique was used to produce calcium phosphate coated on the titanium substrates, and the sputtered coating films were crystallized in an autoclave at 110 ℃ using a low temperature hydrothermal technique. The crystallization of as- sputtered coating film on the titanium substrates were amorphous calcium phosphate film. However, after the hydrothermal technique, calcium phosphate crystals grew and these were columnar crystal. The Ca/ P ratio of sputtered coating films in 1.6 to 2.0.

  11. Study on Titanium Nitride Film Modified for Intraocular Lens

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Objective:To study the characteristics of the intraocular lens using ion beam sputtering depositing titanium nitride thin film on the intraocular lens(IOLs).Methods:To deposite titanium nitride thin film on the top of intraocular lens by ion beam sputtering depositing.We analyzed the surface morphology of intraocular lens through SEM and AFM.We detected intraocular lens resolution through the measurement of intraocular lens.Biocompatibility of intraocular lens is preliminary evaluated in this test.Results:T...

  12. Titanium Corrosion Mechanisms in the Oral Environment: A Retrieval Study

    OpenAIRE

    Danieli C. Rodrigues; Pilar Valderrama; Wilson, Thomas G.; Kelli Palmer; Anie Thomas; Sathyanarayanan Sridhar; Arvind Adapalli; Maria Burbano; Chandur Wadhwani

    2013-01-01

    Corrosion of titanium dental implants has been associated with implant failure and is considered one of the triggering factors for peri-implantitis. This corrosion is concerning, because a large amount of metal ions and debris are generated in this process, the accumulation of which may lead to adverse tissue reactions in vivo. The goal of this study is to investigate the mechanisms for implant degradation by evaluating the surface of five titanium dental implants retrieved due to peri-implan...

  13. Titanium Dioxide as an Osteoconductive Material: An Animal Study

    OpenAIRE

    Harshakumar, Karunakaran; Nair, K. Chandrasekharan; Paulose, N. George; Nair, Vivek V.; Prasanth, V.; Krishnan, Aswathi

    2012-01-01

    The purpose of the present study was to evaluate the biocompatibility and osteoconductive potential of pure and pigment forms of titanium dioxide. Pure and pigment forms of titanium dioxide were incorporated into prepared bur holes in the femur bone of rabbits. Implantation was done on six Albino rabbits which were sacrificed at the end of 3rd, 4th and 5th months after implantation. Radiographic, histologic and scanning electron microscopic evaluations of the implanted sites were performed. H...

  14. Current research situation of titanium alloys in China

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Titanium and its alloys possess excellent comprehensive properties, and they are widely used in many fields. China pays great attentions to the research on new titanium alloys. This paper mainly reviews the research on new Ti alloys in China, for example, high strength and high toughness Ti alloys, burn resistant Tialloys, high temperature Ti alloys, low cost Ti alloys and so on.New basic theories on Ti alloys developed in China in recent years are also reviewed.

  15. Candida albicans biofilm on titanium: effect of peroxidase precoating

    Directory of Open Access Journals (Sweden)

    Mohamed Ahariz

    2010-08-01

    Full Text Available Mohamed Ahariz1, Philippe Courtois1,21Laboratory of Experimental Hormonology, Université Libre de Bruxelles, Brussels, 2UER de Biologie Médicale, Haute Ecole Francisco Ferrer, Brussels, BelgiumAbstract: The present study aimed to document Candida albicans biofilm development on titanium and its modulation by a peroxidase-precoated material which can generate antimicrobials, such as hypoiodite or hypothiocyanite, from hydrogen peroxide, iodide, or thiocyanate. For this purpose, titanium (powder or foil was suspended in Sabouraud liquid medium inoculated with C. albicans ATCC10231. After continuous stirring for 2–21 days at room temperature, the supernatant was monitored by turbidimetry at 600 nm and titanium washed three times in sterile Sabouraud broth. Using the tetrazolium salt MTT-formazan assay, the titanium-adherent fungal biomass was measured as 7.50 ± 0.60 × 106 blastoconidia per gram of titanium powder (n = 30 and 0.50 ± 0.04 × 106 blastoconidia per cm² of titanium foil (n = 12. The presence of yeast on the surface of titanium was confirmed by microscopy both on fresh preparations and after calcofluor white staining. However, in the presence of peroxidase systems (lactoperoxidase with substrates such as hydrogen peroxide donor, iodide, or thiocyanate, Candida growth in both planktonic and attached phases appeared to be inhibited. Moreover, this study demonstrates the possible partition of peroxidase systems between titanium material (peroxidase-precoated and liquid environment (containing peroxidase substrates to limit C. albicans biofilm formation.Keywords: adhesion, material, oral, yeast

  16. In Vitro Analysis of Fibronectin-Modified Titanium Surfaces

    OpenAIRE

    Chang, Yu-Chi; Lee, Wei-Fang; Feng, Sheng-Wei; Huang, Haw-Ming; Lin, Che-Tong; Teng, Nai-Chia; Chang, Wei Jen

    2016-01-01

    Background Glow discharge plasma (GDP) procedure is an effective method for grafting various proteins, including albumin, type I collagen, and fibronectin, onto a titanium surface. However, the behavior and impact of titanium (Ti) surface modification is yet to be unraveled. Purpose The purpose of this study is to evaluate and analyze the biological properties of fibronectin-grafted Ti surfaces treated by GDP. Materials and Methods Grade II Ti discs were initially cleaned and autoclaved to ob...

  17. Corrosion Behaviour of Titanium Anodized Film in Different Corrosive Environments

    Directory of Open Access Journals (Sweden)

    Mr. Sunil D. Kahar

    2014-07-01

    Full Text Available Anodizing is an electrochemical process in which thickness of the natural oxide layer is increased and converted it into a decorative, durable, corrosion-resistant film. Titanium is used as a biocompatible material in human implants due to its excellent corrosion and wears resistance. Stable, continuous, highly adherent, and protective oxide films can be developed on titanium using various acid or alkaline baths. Anodizing of titanium generates a spectrum of different color without use of dyes. This spectrum of color dependent on the thickness of the oxide, voltage ranges, interference of light reflecting off the oxide surface and reflecting off the underlying metal surface. The anodized film of Titanium is mainly consists of TiO2 or mixtures of TiO2 & Ti2O3 etc. In the present work, Pure Titanium plate has been anodized using bath of Chromic Acid at different voltage range. The anodized film is characterized by visual observation, SEM & EDAX analysis & A.C Impedance Spectroscopy, while the corrosion studies were performed using Potentiodynamic studies were performed in 3.5% NaCl & 0.1N H2SO4. The Results show that the anodized film of Titanium show different spectrum of colors from Brown-Violet-Tea or Peacock. SEM & EDAX analyses show that the anodized film of Titanium is mainly made up of TiO2 and Ti2O3. Potentiodynamic study implies that the film developed on Titanium using the bath of Chromic Acid exhibits good corrosion resistance. The A.C. Impedance study shows that the film is more compact, adherent and more uniform in chromic acid bath.

  18. Titanium oxide nanoparticle production using high power pulsed plasmas

    OpenAIRE

    Gunnarsson, Rickard

    2016-01-01

    This thesis covers fundamental aspects of process control when growing titanium oxide nanoparticles in a reactive sputtering process. It covers the influence of oxygen containing gas on the oxidation state of the cathode from which the growth material is ejected, as well as its influence on the particles oxidation state and their nucleation. It was found that a low degree of reactive gases was necessary for nanoparticles of titanium to nucleate. When the oxygen gas was slightly increased, the...

  19. Free carriers in nanocrystalline titanium dioxide thin films

    OpenAIRE

    Springer, Simon; Schmid, Philippe E.

    2005-01-01

    This thesis analyzes the properties of heavily doped nanocrystalline titanium dioxide. Thin films were deposited by magnetron sputtering with either water vapor as reactive gas or a periodically interrupted oxygen supply. The samples were at the same time electrically conducting and transparent. They consisted of mixtures of rutile, anatase and amorphous phases. Titanium dioxide is chemically stable, hard, non-toxic, transparent, and inexpensive. Due to a high refractive index it is often fou...

  20. The immunomodulatory effects of titanium dioxide and silver nanoparticles.

    Science.gov (United States)

    Lappas, Courtney M

    2015-11-01

    Due to their characteristic physical, chemical and optical properties, titanium dioxide and silver nanoparticles are attractive tools for use in a wide range of applications. The use of nanoparticles for biological applications is, however, dependent upon their biocompatibility with living cells. Because of the importance of inflammation as a modulator of human health, the safe and efficacious in vivo use of titanium dioxide and silver nanoparticles is inherently linked to a favorable interaction with immune system cells. However, both titanium dioxide and silver nanoparticles have demonstrated potential to exert immunomodulatory and immunotoxic effects. Titanium dioxide and silver nanoparticles are readily internalized by immune system cells, may accumulate in peripheral lymphoid organs, and can influence multiple manifestations of immune cell activity. Although the factors influencing the biocompatibility of titanium dioxide and silver nanoparticles with immune system cells have not been fully elucidated, nanoparticle core composition, size, concentration and the duration of cell exposure seem to be important. Because titanium dioxide and silver nanoparticles are widely utilized in pharmaceutical, commercial and industrial products, it is vital that their effects on human health and immune system function be more thoroughly evaluated.

  1. Modeling corrosion behavior of gas tungsten arc welded titanium alloy

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The pitting corrosion characteristics of pulse TIG welded Ti-6Al-4V titanium alloy in marine environment were explained.Besides the rapid advance of titanium metallurgy, this is also due to the successful solution of problems associated with the development of titanium alloy welding. The preferred welding process of titanium alloy is frequently gas tungsten arc(GTA) welding due to its comparatively easier applicability and better economy. In the case of single pass GTA welding of thinner section of this alloy, the pulsed current has been found beneficial due to its advantages over the conventional continuous current process. The benefit of the process is utilized to obtain better quality titanium weldments. Four factors, five levels, central composite, rotatable design matrix are used to optimize the required number of experiments. The mathematical models have been developed by response surface method(RSM). The results reveal that the titanium alloy can form a protective scale in marine environment and is resistant to pitting corrosion. Experimental results are provided to illustrate the proposed approach.

  2. Effects of thickness on electronic structure of titanium thin films

    Indian Academy of Sciences (India)

    Güvenç Akgül

    2014-02-01

    Effects of thickness on the electronic structure of e-beam evaporated thin titanium films were studied using near-edge X-ray absorption fine structure (NEXAFS) technique at titanium 2,3 edge in total electron yield (TEY) mode and transmission yield mode. Thickness dependence of 2,3 branching ratio (BR) of titanium was investigated and it was found that BR below 3.5 nm shows a strong dependence on film thickness. Mean electron escape depth () in titanium, an important parameter for surface applications, was determined to be = 2.6 ± 0.1 nm using 2,3 resonance intensity variation as a function of film thickness. The average 3/2 white line intensity ratio of titanium was obtained as 0.89 from the ratio of amplitudes of each 3 and 2 peaks and 0.66 from the integrated area under each 3 and 2 peaks. In addition, a theoretical calculation for pure titanium was presented for comparison with experimental data.

  3. Human Mesenchymal Stem Cell Morphology and Migration on Microtextured Titanium

    Science.gov (United States)

    Banik, Brittany L.; Riley, Thomas R.; Platt, Christina J.; Brown, Justin L.

    2016-01-01

    The implant used in spinal fusion procedures is an essential component to achieving successful arthrodesis. At the cellular level, the implant impacts healing and fusion through a series of steps: first, mesenchymal stem cells (MSCs) need to adhere and proliferate to cover the implant; second, the MSCs must differentiate into osteoblasts; third, the osteoid matrix produced by the osteoblasts needs to generate new bone tissue, thoroughly integrating the implant with the vertebrate above and below. Previous research has demonstrated that microtextured titanium is advantageous over smooth titanium and PEEK implants for both promoting osteogenic differentiation and integrating with host bone tissue; however, no investigation to date has examined the early morphology and migration of MSCs on these surfaces. This study details cell spreading and morphology changes over 24 h, rate and directionality of migration 6–18 h post-seeding, differentiation markers at 10 days, and the long-term morphology of MSCs at 7 days, on microtextured, acid-etched titanium (endoskeleton), smooth titanium, and smooth PEEK surfaces. The results demonstrate that in all metrics, the two titanium surfaces outperformed the PEEK surface. Furthermore, the rough acid-etched titanium surface presented the most favorable overall results, demonstrating the random migration needed to efficiently cover a surface in addition to morphologies consistent with osteoblasts and preosteoblasts. PMID:27243001

  4. Formation of Biomimetic Hydroxyapatite Coating on Titanium Plates

    Directory of Open Access Journals (Sweden)

    Ievgen Volodymyrovych PYLYPCHUK

    2014-09-01

    Full Text Available Hydroxyapatite (HA has long been used as a coating material in the implant industry for orthopedic implant applications. HA is the natural inorganic constituent of bone and teeth. By coating titanium (base material of implant engineering because of its lightness and durability with hydroxyapatite, we can provide higher biocompatibility of titanium implants, according to HA ability to form a direct biochemical bond with living tissues. This article reports a biomimetic approach for coating hydroxyapatite with titanium A method of modifying the surface of titanium by organic modifiers (for creating functional groups on the surface, followed by formation "self-assembled" layer of biomimetic hydroxyapatite in simulated body fluid (SBF. FTIR and XPS confirmed the formation of hydroxyapatite coatings on titanium surface. Comparative study of the formation of HA on the surface of titanium plates modified by different functional groups: Ti(≡OH, Ti/(≡Si-OH and Ti/(≡COOH is conducted. It was found that the closest to natural stoichiometric hydroxyapatite Ca/P ratio was obtained on Ti/(≡COOH samples. DOI: http://dx.doi.org/10.5755/j01.ms.20.3.4974

  5. Adhesion of osteoblasts to a nanorough titanium implant surface

    Directory of Open Access Journals (Sweden)

    Gongadze E

    2011-08-01

    Full Text Available Ekaterina Gongadze1, Doron Kabaso2, Sebastian Bauer3, Tomaž Slivnik2, Patrik Schmuki3, Ursula van Rienen1, Aleš Iglič21Institute of General Electrical Engineering, University of Rostock, Rostock, Germany; 2Laboratory of Biophysics, Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia; 3Department of Materials Science, Friedrich-Alexander University of Erlangen-Nurenberg, Erlangen, GermanyAbstract: This work considers the adhesion of cells to a nanorough titanium implant surface with sharp edges. The basic assumption was that the attraction between the negatively charged titanium surface and a negatively charged osteoblast is mediated by charged proteins with a distinctive quadrupolar internal charge distribution. Similarly, cation-mediated attraction between fibronectin molecules and the titanium surface is expected to be more efficient for a high surface charge density, resulting in facilitated integrin mediated osteoblast adhesion. We suggest that osteoblasts are most strongly bound along the sharp convex edges or spikes of nanorough titanium surfaces where the magnitude of the negative surface charge density is the highest. It is therefore plausible that nanorough regions of titanium surfaces with sharp edges and spikes promote the adhesion of osteoblasts.Keywords: osteoblasts, nanostructures, adhesion, titanium implants, osteointegration

  6. Biocompatibility of beta-stabilizing elements of titanium alloys.

    Science.gov (United States)

    Eisenbarth, E; Velten, D; Müller, M; Thull, R; Breme, J

    2004-11-01

    In comparison to the presently used alpha + beta titanium alloys for biomedical applications, beta-titanium alloys have many advantageous mechanical properties, such as an improved wear resistance, a high elasticity and an excellent cold and hot formability. This will promote their future increased application as materials for orthopaedic joint replacements. Not all elements with beta-stabilizing properties in titanium alloys are suitable for biomaterial applications-corrosion and wear processes cause a release of these alloying elements to the surrounding tissue. In this investigation, the biocompability of alloying elements for beta- and near beta-titanium alloys was tested in order to estimate their suitability for biomaterial components. Titanium (grade 2) and the implant steel X2CrNiMo18153 (AISI 316 L) were tested as reference materials. The investigation included the corrosion properties of the elements, proliferation, mitochondrial activity, cell morphology and the size of MC3T3-E1 cells and GM7373 cells after 7 days incubation in direct contact with polished slices of the metals. The statistical significance was considered by Weir-test and Lord-test (alpha = 0.05). The biocompatibility range of the investigated metals is (decreasing biocompatibility): niobium-tantalum, titanium, zirconium-aluminium-316 L-molybdenum.

  7. Surface modification by alkali and heat treatments in titanium alloys.

    Science.gov (United States)

    Lee, Baek-Hee; Do Kim, Young; Shin, Ji Hoon; Hwan Lee, Kyu

    2002-09-01

    Pure titanium and titanium alloys are normally used for orthopedic and dental prostheses. Nevertheless, their chemical, biological, and mechanical properties still can be improved by the development of new preparation technologies. This has been the limiting factor for these metals to show low affinity to living bone. The purpose of this study is to improve the bone-bonding ability between titanium alloys and living bone through a chemically activated process and a thermally activated one. Two kinds of titanium alloys, a newly designed Ti-In-Nb-Ta alloy and a commercially available Ti-6Al-4V ELI alloy, were used in this study. In this study, surface modification of the titanium alloys by alkali and heat treatments (AHT), alkali treated in 5.0M NaOH solution, and heat treated in vacuum furnace at 600 degrees C, is reported. After AHT, the effects of the AHT on the bone integration property were evaluated in vitro. Surface morphologies of AHT were observed by optical microscopy (OM) and scanning electron microscopy (SEM). Chemical compositional surface changes were investigated by X-ray diffractometry (XRD), energy dispersive spectroscopy (EDS), and auger electron spectroscopy (AES). Titanium alloys with surface modification by AHT showed improved bioactive behavior, and the Ti-In-Nb-Ta alloy had better bioactivity than the Ti-6Al-4V ELI alloy in vitro.

  8. Properties of titanium-alloyed DLC layers for medical applications.

    Science.gov (United States)

    Joska, Ludek; Fojt, Jaroslav; Cvrcek, Ladislav; Brezina, Vitezslav

    2014-01-01

    DLC-type layers offer a good potential for application in medicine, due to their excellent tribological properties, chemical resistance, and bio-inert character. The presented study has verified the possibility of alloying DLC layers with titanium, with coatings containing three levels of titanium concentration prepared. Titanium was present on the surface mainly in the form of oxides. Its increasing concentration led to increased presence of titanium carbide as well. The behavior of the studied systems was stable during exposure in a physiological saline solution. Electrochemical impedance spectra practically did not change with time. Alloying, however, changed the electrochemical behavior of coated systems in a significant way: from inert surface mediating only exchange reactions of the environment in the case of unalloyed DLC layers to a response corresponding rather to a passive surface in the case of alloyed specimens. The effect of DLC layers alloying with titanium was tested by the interaction with a simulated body fluid, during which precipitation of a compound containing calcium and phosphorus--basic components of the bone apatite--occurred on all doped specimens, in contrast to pure DLC. The results of the specimens' surface colonization with cells test proved the positive effect of titanium in the case of specimens with a medium and highest content of this element.

  9. Nanoscale Bonding between Human Bone and Titanium Surfaces: Osseohybridization

    Directory of Open Access Journals (Sweden)

    Jun-Sik Kim

    2015-01-01

    Full Text Available Until now, the chemical bonding between titanium and bone has been examined only through a few mechanical detachment tests. Therefore, in this study, a sandblasted and acid-etched titanium mini-implant was removed from a human patient after 2 months of placement in order to identify the chemical integration mechanism for nanoscale osseointegration of titanium implants. To prepare a transmission electron microscopy (TEM specimen, the natural state was preserved as much as possible by cryofixation and scanning electron microscope/focused ion beam (SEM-FIB milling without any chemical treatment. High-resolution TEM (HRTEM, energy dispersive X-ray spectroscopy (EDS, and scanning TEM (STEM/electron energy loss spectroscopic analysis (EELS were used to investigate the chemical composition and structure at the interface between the titanium and bone tissue. HRTEM and EDS data showed evidence of crystalline hydroxyapatite and intermixing of bone with the oxide layer of the implant. The STEM/EELS experiment provided particularly interesting results: carbon existed in polysaccharides, calcium and phosphorus existed as tricalcium phosphate (TCP, and titanium existed as oxidized titanium. In addition, the oxygen energy loss near edge structures (ELNESs showed a possibility of the presence of CaTiO3. These STEM/EELS results can be explained by structures either with or without a chemical reaction layer. The possible existence of the osseohybridization area and the form of the carbon suggest that reconsideration of the standard definition of osseointegration is necessary.

  10. Cadmium Telluride-Titanium Dioxide Nanocomposite for Photodegradation of Organic Substance.

    Science.gov (United States)

    Ontam, Areeporn; Khaorapapong, Nithima; Ogawa, Makoto

    2015-12-01

    Cadmium telluride-titanium dioxide nanocomposite was prepared by hydrothermal reaction of sol-gel derived titanium dioxide and organically modified cadmium telluride. The crystallinity of titanium dioxide in the nanocomposite was higher than that of pure titanium dioxide obtained by the reaction under the same temperature and pressure conditions, showing that cadmium telluride induced the crystallization of titanium dioxide. Diffuse reflectance spectrum of the nanocomposite showed the higher absorption efficiency in the UV-visible region due to band-gap excitation of titanium dioxide. The nanocomposite significantly showed the improvement of photocatalytic activity for 4-chlorophenol with UV light.

  11. Effect of titanium addition on fracture toughness behavior of ZL108 alloy

    Institute of Scientific and Technical Information of China (English)

    WENG Yong-gang; LI Zi-jing; LIU Zhi-yong; LIU Wen-cai; WANG Ming-xing; SONG Tian-fu

    2006-01-01

    Two different titanium alloying methods were applied to ZL108 alloy for preparing specimens containing titanium. The specimens were tested on the MTS 810 material test system for studying their behavior of the plane strain fracture toughness KIC. The experimental data were analyzed by the statistical significance tests. The results show that the fracture toughness of the ZL108 alloy containing titanium is superior to that of common ZL108 alloy containing no titanium, but there is no significant difference for different titanium alloying methods. Therefore titanium addition is an effective method for improving the fracture toughness of the alloy ZL108.

  12. Study on titanium foil coated with partial reduction titanium dioxide as bipolar lead-acid battery's substrate

    Science.gov (United States)

    Lang, Xiaoshi; Wang, Dianlong; Tang, Shenzhi; Zhu, Junsheng; Guo, Chenfeng

    2014-12-01

    Pure titanium foil cannot be directly as the substrate for the bipolar lead-acid battery due to its surface oxidized into titanium dioxide in the cell cycle. The poor electronic conductivity of titanium dioxide will increase substrate's ohmic resistance and can affect the cell's electrochemical performances. In this paper, titanium foil's surface is coated with a lay of partial reduction titanium dioxide (TiO2-x) which has excellent chemical stability and high electronic conductivity by means of sol-gel method. Through XRD, SEM and four-probe test, it shows that the modified titanium's surface has the most superior crystal structure and morphology and the highest electronic conductivity in the sintering temperature of 800 °C. We subsequently assemble bipolar lead-acid batteries with Ti coated by TiO2-x as the substrate material. The batteries are discovered that when charged and discharged in 3.5 V-4.84 V at 0.5C the voltage between the charge and discharge voltage platform is 0.3 V, and the initial discharge specific capacity can reach 80 mAh g-1. When the current rate is up to 1C and 2C, the initial discharge specific capacity is 70 mAh g-1and 60 mAh g-1. After 100 cycles, the initial specific capacity only decreases 12.5%.

  13. Computer precision simulation for titanium casting centrifugal mold filling of prescision titanium castings

    Directory of Open Access Journals (Sweden)

    Daming XU

    2004-08-01

    Full Text Available Computer simulation codes were developed based on proposed mathematical model for centrifugal mold filling processes and previous computer software for 3D mold filling and solidification of castings. Sample simulations were implemented for mold filling processes of precision titanium castings under gravity and different centrifugal casting techniques. The computation results show that the alloy melt has a much stronger mold filling ability for thin section castings unde a centrifugal force field than that only under the gravity. A "return back" mold filling manner is showed to be a reasonable technique for centrifugal casting processes, especially for thin section prcision castings.

  14. H/G非骨水泥人工全髋关节置换术后聚乙烯内杯磨损临床研究%Polyethylene wear and osteolysis in H/G cementless total hip arthroplasty

    Institute of Scientific and Technical Information of China (English)

    文立成; 李军; 马忠泰

    2009-01-01

    目的 对H/G非骨水泥人工全髋关节置换术后聚乙烯内杯的磨损及髋臼周围骨溶解的情况进行总结.方法 我院1991至1995年共进行58例(65髋)H/G非骨水泥人工全髋关节置换,其中35例(40髋)获得10年以上随访.对这35例(40髋)患者获得随访的病例,采用计算机数字化方法测量髋臼聚乙烯内杯的二维线性磨损.结果 35例40髋均有不同程度的磨损,磨损范围2~8 mm,平均磨损为(0.32±0.31)mm/年.10髋聚乙烯磨损超过6 mm,髋臼假体周围的骨溶解严重,并伴有金属假体的移位,其中5髋聚乙烯内杯完伞磨透,金属股骨头与金属髋臼相接触;5髋聚乙烯内杯磨损严重伴明显骨溶解,内杯松动.2髋聚乙烯内杯脱位.共实施翻修手术12例,包括更换聚乙烯内杯和金属股骨头2例、金属闩杯翻修2例、全髋翻修8例.28髋在髋臼侧发现骨溶解,其中14髋股骨侧亦有骨溶解发生.结论 本组病例所观测到的H/G髋臼聚乙烯内杯的磨损程度超过文献所报道,而且由于磨损产生的大量磨屑,导致假体周围出现明显骨溶解,直接影响到假体的稳定.关节置换术后应定期随访,避免出现严重骨溶解后增加翻修手术的困难.%Objectives To measure the linear polyethelene wear with use of a computer-assisted two-dimensional method, and to evaluate the relationship between wear and long-term clinic-radiological findings. Methods Between December 1991 and December 1995, the senior author performed 40 primary total hip arthroplasties with use of H/G porous-coated acetabular component Radiographs of 40 H/G cementless total hip arthroplasies were examined for osteolysis, radiolucent line, cup migration and so on. To measure the linear polyethylene wear, migration in the femoral head center relative to the cup shell center was calculated on digitized consecutive radiographs with special computer software program. Results The minimum follow-up was 10 years. Total linear wear

  15. Development and Evaluation of Titanium Space Suit Bearings

    Science.gov (United States)

    Rhodes, Richard; Battisti, Brian; Ytuarte, Ray, Jr.; Schultz, Bradley

    2016-01-01

    The Z-2 Prototype Planetary Extravehicular Space Suit Assembly is a continuation of NASA's Z series of spacesuits, designed with the intent of meeting a wide variety of exploration mission objectives, including human exploration of the Martian surface. Incorporating titanium bearings into the Z series space suit architecture allows us to reduce mass by an estimated 23 pounds per suit system compared to the previously used stainless steel bearing designs without compromising suit functionality. There are two obstacles to overcome when using titanium for a bearing race: 1) titanium is flammable when exposed to the oxygen wetted environment inside the space suit and 2) titanium's poor wear properties are often challenging to overcome in tribology applications. In order to evaluate the ignitability of a titanium space suit bearing, a series of tests were conducted at White Sands Test Facility that introduced the bearings to an extreme test profile, with multiple failures imbedded into the test bearings. The testing showed no signs of ignition in the most extreme test cases; however, substantial wear of the bearing races was observed. In order to design a bearing that can last an entire exploration mission (approximately 2 years), bearing test rigs were developed that allow for the quick evaluation of various bearing ball loads, ball diameters, lubricants, and surface treatments. This test data will allow designers to minimize the titanium bearing mass for a specific material and lubricant combination around a maximum contact stress that will allow the bearing to survive the life of an exploration mission. This paper reviews the current research and testing that has been performed on titanium bearing races to evaluate the use of such materials in an enriched oxygen environment and to optimize the bearing assembly mass and tribological properties to accommodate for the high bearing cycle life for an exploration mission.

  16. Electrochemical Investigation of Doped Titanium Dioxide

    Directory of Open Access Journals (Sweden)

    J. W. J. Hamilton

    2008-01-01

    Full Text Available Thin films of transition-metal doped (0.2, 1.0, and 5.0 atom% TiO2 were prepared on titanium foil using a sol-gel route catalyzed by ammonium acetate. Dopants investigated were the fourth-period transition metals. The prepared films were characterised by Raman spectroscopy, Auger electron spectroscopy, and photoelectrochemical methods. The films doped with transition metals showed a lower photocurrent response than undoped samples. No major red shift in the photocurrent response spectra of the doped films was observed. A photocurrent response was observed under visible light irradiation of the samples and was potential dependent peaking around −0.3 V (SCE, which is indicative of electron promotion from a filled defect level. Examination of the defect level potential dependence by analysis of the current-time response under chopped illumination at fixed potential (−0.8 V–+1.07 V gave a good correlation with the potential dependence observed in the visible light irradiation studies.

  17. Toxicology of nanosized titanium dioxide: an update.

    Science.gov (United States)

    Zhang, Xiaochen; Li, Wen; Yang, Zhuo

    2015-12-01

    Nanosized titanium dioxide (nano-TiO2) has tremendous potential for a host of applications, and TiO2 nanoparticles (NP) possess different physicochemical properties compared to their fine particle analogs, which might alter their bioactivity. Their adverse effects on living cells have raised serious concerns recently for their use in health care and consumer sectors such as sunscreens, cosmetics, pharmaceutical additives and implanted biomaterials. Many researches have demonstrated that the physicochemical properties including shape, size, surface characteristics and inner structure of nano-TiO2 particles have different degrees of toxicity to different organism groups under different conditions. Some former reports have demonstrated that nano-TiO2 materials could enter into human body through different routes such as inhalation, dermal penetration and ingestion. After being taken by human body, NP might induce oxidative stress, cytotoxicity, genotoxicity, inflammation and cell apoptosis ultimately in mammal organs and systems. Here, we summarized the update about toxicity of nano-TiO2 and aimed to supply a safety usage guideline of this nanomaterial.

  18. Amorphous Alloy Surpasses Steel and Titanium

    Science.gov (United States)

    2004-01-01

    In the same way that the inventions of steel in the 1800s and plastic in the 1900s sparked revolutions for industry, a new class of amorphous alloys is poised to redefine materials science as we know it in the 21st century. Welcome to the 3rd Revolution, otherwise known as the era of Liquidmetal(R) alloys, where metals behave similar to plastics but possess more than twice the strength of high performance titanium. Liquidmetal alloys were conceived in 1992, as a result of a project funded by the California Institute of Technology (CalTech), NASA, and the U.S. Department of Energy, to study the fundamentals of metallic alloys in an undercooled liquid state, for the development of new aerospace materials. Furthermore, NASA's Marshall Space Flight Center contributed to the development of the alloys by subjecting the materials to testing in its Electrostatic Levitator, a special instrument that is capable of suspending an object in midair so that researchers can heat and cool it in a containerless environment free from contaminants that could otherwise spoil the experiment.

  19. Antibacterial titanium surfaces for medical implants.

    Science.gov (United States)

    Ferraris, S; Spriano, S

    2016-04-01

    Bacterial contamination is a critical problem in different fields (ranging from everyday life to space missions, and from medicine to biosensing). Specifically, in the case of medical implants, foreign materials are preferential sites for bacterial adhesion and microbial contamination, which can lead to the development of prosthetic infections. These problems can in turn lead to the necessity of a prolonged antibiotic therapy (which can last for years) and eventually to the removal of the device, with a consequent significant increase in the hospitalization times and costs, together with a stressful, painful and critical situation for the patient. Commercially pure titanium and its alloys are the most commonly used materials for permanent implants in contact with bone, and the prevention of infections on their surface is therefore a crucial challenge for orthopaedic and dental surgeons. The problem of the bacterial contamination of medical implants is briefly described in the first part of the present review. Then the most important inorganic antibacterial agents (Ag, Cu and Zn) are described, and this is followed by a review of the reported attempts of their introduction onto the surface of Ti-based substrates. PMID:26838926

  20. As-cast titanium aluminides microstructure modification

    Directory of Open Access Journals (Sweden)

    A. Duarte

    1999-07-01

    Full Text Available Two cast g titanium aluminides, Ti47Al and Ti50Al (at. %, were obtained by arc melting under an argon atmosphere. The as-cast microstructure modification by annealing under protective argon atmosphere and hot isostatic pressing (HIP was analysed by optical and scanning electron microscopy with microanalysis facilities. As-cast structures presented strong microsegregations, being composed of primary a dendrites (with low Al content, which transformed into lamellar a2 + g during solid state cooling, and interdendritic g phase (with high Al content. Annealing in the a + g field was responsible for a partial reduction of microsegregation, a decreasing of the volume fraction of a2 + g lamellar dendrites, an increasing of g volume fraction and the occurrence of a small fraction of a2 particles and plates in some of the g grains. Annealing in the a field at 1400 °C for one hour was insufficient to eliminate the as-cast microstructure in the Ti50Al alloy and produced large equiaxed lamellar colonies of a2+g in the Ti47Al alloy. HIP in the a + g field (to avoid excessive grain growth was responsible for microstructure modifications similar to the ones obtained by heat treating under similar soaking conditions.

  1. Damage Resistance of Titanium Aluminide Evaluated

    Science.gov (United States)

    Lerch, Bradley A.; Draper, Susan L.; Baaklini, George Y.; Pereira, J. Michael; Austin, Curt

    2000-01-01

    As part of the aviation safety goal to reduce the aircraft accident rate, NASA has undertaken studies to develop durable engine component materials. One of these materials, g-TiAl, has superior high-temperature material properties. Its low density provides improved specific strength and creep resistance in comparison to currently used titanium alloys. However, this intermetallic is inherently brittle, and long life durability is a potential problem. Of particular concern is the material s sensitivity to defects, which may form during the manufacturing process or in service. To determine the sensitivity of TiAl to defects, a team consisting of GE Aircraft Engines, Precision Cast Parts, and NASA was formed. The work at the NASA Glenn Research Center at Lewis Field has concentrated on the fatigue response to specimens containing defects. The overall objective of this work is to determine the influence of defects on the high cycle fatigue life of TiAl-simulated low-pressure turbine blades. Two types of defects have been introduced into the specimens: cracking from impact damage and casting porosity. For both types of defects, the cast-to-size fatigue specimens were fatigue tested at 650 C and 100 Hz until failure.

  2. Subcritical crack growth in two titanium alloys.

    Science.gov (United States)

    Williams, D. N.

    1973-01-01

    Measurement of subcritical crack growth during static loading of precracked titanium alloys in salt water using samples too thin for plane strain loading to predominate was examined as a method for determining the critical stress intensity for crack propagation in salt water. Significant internal crack growth followed by arrest was found at quite low stress intensities, but crack growth rates were relatively low. Assuming these techniques provided a reliable measurement of the critical stress intensity, the value for annealed Ti-4Al-1.5Mo-0.5V alloy was apparently about 35 ksi-in. to the 1/2 power, while that for annealed Ti-4Al-3Mo-1V was below 45 ksi-in. to the 1/2 power. Crack growth was also observed in tests conducted in both alloys in an air environment. At 65 ksi-in. to the 1/2 power, the extent of crack growth was greater in air than in salt water. Ti-4Al-3Mo-1V showed arrested crack growth in air at a stress intensity of 45 ksi-in. to the 1/2 power.

  3. Titanium photocatalyst against human pathogenic microorganisms

    International Nuclear Information System (INIS)

    The conventional methods of disinfection are not effective in the longer term. They are time and staff intensive and use aggressive chemicals. Photocatalytic oxidation on surfaces coated with titanium dioxide (TiO2) might offer a possible alternative. The antimicrobial activity of TiO2 powder P25 and thin films of TiO2 on glass slides against representative strains of microorganisms associated with hospital-acquired infections (Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans) was investigated in vitro. High efficiency has been found in the case of the studied bacterial strains, particularly for the P. aeruginosa. It was shown that it is possible to disinfect surfaces coated with TiO2 and stimulated by UV-A light. The reduction efficiencies for P. aeruginosa, S. aureus and C. albicans were 3.19, 2.32 and 1.22. In all cases sublethal UV-A doses provoked an important lethality in the presence of TiO2. (authors)

  4. Surface spectroscopic characterization of titanium implant materials

    Science.gov (United States)

    Lausmaa, Jukka; Kasemo, Bengt; Mattsson, Håkan

    1990-04-01

    Titanium is one of the most commonly used biomaterials for dental and orthopedic applications. Its excellent tissue compatibility is mainly due to the properties of the stable oxide layer which is present on the surface. This paper reports a detailed spectroscopic characterization of the surface composition of non-alloyed Ti implant materials, prepared according to procedures commonly used in clinical practice (machining, ultrasonic cleaning and sterilization). The main methods of characterization are XPS and AES, and complementary information is obtained by SIMS, EDX and NMA (nuclear microanalysis). The surface of the implants is found to consist of a thin surface oxide which is covered by a carbon-dominated contamination layer. By comparison with reference spectra from single crystal TiO 2 (rutile) the composition of the surface oxide is shown to be mainly TiO 2, with minor amounts of suboxides and TiN x. The thickness of the surface oxides is 2-6 nm, depending on the method of sterilization. The surface contamination layer is found to vary considerably from sample to sample and consists of mainly hydrocarbons with trace amounts of Ca, N, S, P, Cl. Some differences in surface composition between directly prepared surfaces, and some possible contamination sources, are identified and discussed shortly.

  5. Fully CMOS-compatible titanium nitride nanoantennas

    International Nuclear Information System (INIS)

    CMOS-compatible fabrication of plasmonic materials and devices will accelerate the development of integrated nanophotonics for information processing applications. Using low-temperature plasma-enhanced atomic layer deposition (PEALD), we develop a recipe for fully CMOS-compatible titanium nitride (TiN) that is plasmonic in the visible and near infrared. Films are grown on silicon, silicon dioxide, and epitaxially on magnesium oxide substrates. By optimizing the plasma exposure per growth cycle during PEALD, carbon and oxygen contamination are reduced, lowering undesirable loss. We use electron beam lithography to pattern TiN nanopillars with varying diameters on silicon in large-area arrays. In the first reported single-particle measurements on plasmonic TiN, we demonstrate size-tunable darkfield scattering spectroscopy in the visible and near infrared regimes. The optical properties of this CMOS-compatible material, combined with its high melting temperature and mechanical durability, comprise a step towards fully CMOS-integrated nanophotonic information processing

  6. Fully CMOS-compatible titanium nitride nanoantennas

    Energy Technology Data Exchange (ETDEWEB)

    Briggs, Justin A., E-mail: jabriggs@stanford.edu [Department of Applied Physics, Stanford University, 348 Via Pueblo Mall, Stanford, California 94305 (United States); Department of Materials Science and Engineering, Stanford University, 496 Lomita Mall, Stanford, California 94305 (United States); Naik, Gururaj V.; Baum, Brian K.; Dionne, Jennifer A. [Department of Materials Science and Engineering, Stanford University, 496 Lomita Mall, Stanford, California 94305 (United States); Petach, Trevor A.; Goldhaber-Gordon, David [Department of Physics, Stanford University, 382 Via Pueblo Mall, Stanford, California 94305 (United States)

    2016-02-01

    CMOS-compatible fabrication of plasmonic materials and devices will accelerate the development of integrated nanophotonics for information processing applications. Using low-temperature plasma-enhanced atomic layer deposition (PEALD), we develop a recipe for fully CMOS-compatible titanium nitride (TiN) that is plasmonic in the visible and near infrared. Films are grown on silicon, silicon dioxide, and epitaxially on magnesium oxide substrates. By optimizing the plasma exposure per growth cycle during PEALD, carbon and oxygen contamination are reduced, lowering undesirable loss. We use electron beam lithography to pattern TiN nanopillars with varying diameters on silicon in large-area arrays. In the first reported single-particle measurements on plasmonic TiN, we demonstrate size-tunable darkfield scattering spectroscopy in the visible and near infrared regimes. The optical properties of this CMOS-compatible material, combined with its high melting temperature and mechanical durability, comprise a step towards fully CMOS-integrated nanophotonic information processing.

  7. Comparative analysis of weld properties of titanium-niobium, titanium molybdenum and stainless steel archwires

    Directory of Open Access Journals (Sweden)

    Vinod Pattabiraman

    2014-01-01

    Full Text Available Objective: Ability to achieve sound weld joints is a desirable characteristic for orthodontic archwires. Titanium molybdenum alloy (TMA has been the only truly weldable orthodontic archwire alloy until now. Titanium-niobium (Ti-Nb alloy archwires exhibit similar mechanical properties as TMA. Whether sound weld joints can be produced in these wires has not been evaluated thus far. In this study Ti-Nb alloy archwires were compared with TMA and stainless steel (SS for weld quality, with SS wires serving as the control group. Materials and Methods: Weld joint strength was assessed by subjecting welded samples of TMA, Ti-Nb and SS wires (0.017 Χ 0.025-inch to a tensile load. The weld joints were also qualitatively assessed by studying the surface characteristics under a scanning electron microscope and the metallographic features under an optical microscope. Results: The weld joint of TMA wire was found to be superior in terms of the strength, surface and metallographic characteristics of the weld joint. Weld joints in Ti-Nb wires had higher strength than those of SS though statistically insignificant. Conclusion: The study concluded that TMA wires are superior to Ti-Nb and SS wires in situations where weldability is a desirable characteristic.

  8. Silicon-Doped Titanium Dioxide Nanotubes Promoted Bone Formation on Titanium Implants.

    Science.gov (United States)

    Zhao, Xijiang; Wang, Tao; Qian, Shi; Liu, Xuanyong; Sun, Junying; Li, Bin

    2016-02-26

    While titanium (Ti) implants have been extensively used in orthopaedic and dental applications, the intrinsic bioinertness of untreated Ti surface usually results in insufficient osseointegration irrespective of the excellent biocompatibility and mechanical properties of it. In this study, we prepared surface modified Ti substrates in which silicon (Si) was doped into the titanium dioxide (TiO₂) nanotubes on Ti surface using plasma immersion ion implantation (PIII) technology. Compared to TiO₂ nanotubes and Ti alone, Si-doped TiO₂ nanotubes significantly enhanced the expression of genes related to osteogenic differentiation, including Col-I, ALP, Runx2, OCN, and OPN, in mouse pre-osteoblastic MC3T3-E1 cells and deposition of mineral matrix. In vivo, the pull-out mechanical tests after two weeks of implantation in rat femur showed that Si-doped TiO₂ nanotubes improved implant fixation strength by 18% and 54% compared to TiO₂-NT and Ti implants, respectively. Together, findings from this study indicate that Si-doped TiO₂ nanotubes promoted the osteogenic differentiation of osteoblastic cells and improved bone-Ti integration. Therefore, they may have considerable potential for the bioactive surface modification of Ti implants.

  9. Direct observation of titanium-centered octahedra in titanium-antimony-tellurium phase-change material.

    Science.gov (United States)

    Rao, Feng; Song, Zhitang; Cheng, Yan; Liu, Xiaosong; Xia, Mengjiao; Li, Wei; Ding, Keyuan; Feng, Xuefei; Zhu, Min; Feng, Songlin

    2015-11-27

    Phase-change memory based on Ti0.4Sb2Te3 material has one order of magnitude faster Set speed and as low as one-fifth of the Reset energy compared with the conventional Ge2Sb2Te5 based device. However, the phase-transition mechanism of the Ti0.4Sb2Te3 material remains inconclusive due to the lack of direct experimental evidence. Here we report a direct atom-by-atom chemical identification of titanium-centered octahedra in crystalline Ti0.4Sb2Te3 material with a state-of-the-art atomic mapping technology. Further, by using soft X-ray absorption spectroscopy and density function theory simulations, we identify in amorphous Ti0.4Sb2Te3 the titanium atoms preferably maintain the octahedral configuration. Our work may pave the way to more thorough understanding and tailoring of the nature of the Ti-Sb-Te material, for promoting the development of dynamic random access memory-like phase-change memory as an emerging storage-class memory to reform current memory hierarchy.

  10. Effect of electrolysis voltage on electrochemical reduction of titanium oxide to titanium in molten calcium chloride

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The electrochemical reduction of solid TiO2 directly to solid metal is a ptomising alternative to the current Kroll process. The present work is aimed at studying the effect of electrolysis voltage on the rate of electrochemical reduction. The products of electrochemical reduction of TiO2 and Ti2O were examined using the scanning electron microscopy (SEM) and X-ray diffraction (XRD) techniques. The results show that Ti2O was reduced to low valent titanium oxide at 1.5 -1.7 V, which was the result of ionization of oxygen. TiO2 and Ti2O were reduced to titanium metal at 2.1-3.1 V, which was the co-action of ionization of oxygen and calciothermic reduction. The oxygen content decreased rapidly with voltage increasing from 2.1 to 2.6 V, while it changed little from 2.6 to 3.1 V. The optimized cell voltage was 2.6-3.1 V.

  11. Effect of Carburization on the Mechanical Properties of Biomedical Grade Titanium Alloys

    Institute of Scientific and Technical Information of China (English)

    Yong Luo; Haibo Jiang; Gang Cheng; Hongtao Liu

    2011-01-01

    Titanium cermets were successfully synthesized on the surface of biomedical grade titanium alloys by using sequential carburization method. The mechanical properties such as hardness, fracture toughness and plasticity were measured to estimate the potential application of titanium cermets. The results show that after carburization the surface hardness of titanium cermets was 778 HV, with a significant improvement of 128% compared with that of titanium alloys. In addition, the fracture toughness of titanium cermets was 21.5×106 Pa·m1/2, much higher than that of other ceramics. Furthermore, the analysis of the loading-unloading curve in the nanoindentation test also indicates that the plasticity of titanium cermet reached 32.1%, a relatively high value which illustrates the combination of the metal and ceramics properties. The results suggest that sequential carburization should be an efficient way to produce titanium cermets with hard surface, high toughness and plasticity.

  12. Recent research and development in titanium alloys for biomedical applications and healthcare goods

    Directory of Open Access Journals (Sweden)

    Mitsuo Niinomi

    2003-01-01

    Full Text Available Nb, Ta and Zr are the favorable non-toxic alloying elements for titanium alloys for biomedical applications. Low rigidity titanium alloys composed of non-toxic elements are getting much attention. The advantage of low rigidity titanium alloy for the healing of bone fracture and the remodeling of bone is successfully proved by fracture model made in tibia of rabbit. Ni-free super elastic and shape memory titanium alloys for biomedical applications are energetically developed. Titanium alloys for not only implants, but also dental products like crowns, dentures, etc. are also getting much attention in dentistry. Development of investment materials suitable for titanium alloys with high melting point is desired in dental precision castings. Bioactive surface modifications of titanium alloys for biomedical applications are very important for achieving further developed biocompatibility. Low cost titanium alloys for healthcare goods, like general wheel chairs, etc. has been recently proposed.

  13. Study on interface between titanium-coated diamond and metal matrices

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The XRD spectrum of titanium-coated diamond showed the existence of titanium carbide on the interface between diamond and its titanium coating. The diffusions between titanium coating and metal matrices were studied by SEM. The SEM photographs revealed that titanium can interdiffuse with nickel, cobalt, copper,iron and copper-based alloy to a great extent to lead to the disappearance of pure titanium layer and the formation of titanium diffusion layer. The results from transverse-rupture strength test showed that titanium coating on diamond improved the bonding strength between diamond and metal matrices by 3.2% for Co-based segment and 4.1% for Cu-10Sn based segment respectively.

  14. Implants for surgery -- Metallic materials -- Part 3: Wrought titanium 6-aluminium 4-vanadium alloy

    CERN Document Server

    International Organization for Standardization. Geneva

    1996-01-01

    Specifies the characteristics of, and corresponding test methods for, the wrought titanium alloy known as titanium 6-aluminium 4-vanadium alloy (Ti 6-Al 4-V alloy) for use in the manufacture of surgical implants.

  15. BMP-2 and titanium particles synergistically activate osteoclast formation

    Energy Technology Data Exchange (ETDEWEB)

    Sun, S.X. [Affiliated Hospital of Ningxia Medical University, Department of Orthopedics, Yinchuan, Ningxia Hui Autonomous Region, China, Department of Orthopedics, Affiliated Hospital of Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region (China); Guo, H.H. [Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region, China, Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region (China); Zhang, J. [Institute of Pathology, Xi' an Jiaotong University, Xi' an Shaanxi, China, Institute of Pathology, Xi' an Jiaotong University, Xi' an Shaanxi (China); Yu, B. [Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region, China, Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region (China); Sun, K.N.; Jin, Q.H. [Affiliated Hospital of Ningxia Medical University, Department of Orthopedics, Yinchuan, Ningxia Hui Autonomous Region, China, Department of Orthopedics, Affiliated Hospital of Ningxia Medical University, Yinchuan, Ningxia Hui Autonomous Region (China)

    2014-05-09

    A previous study showed that BMP-2 (bone morphogenetic protein-2) and wear debris can separately support osteoclast formation induced by the receptor activator of NF-κB ligand (RANKL). However, the effect of BMP-2 on wear debris-induced osteoclast formation is unclear. In this study, we show that neither titanium particles nor BMP-2 can induce osteoclast formation in RAW 264.7 mouse leukemic monocyte macrophage cells but that BMP-2 synergizes with titanium particles to enhance osteoclast formation in the presence of RANKL, and that at a low concentration, BMP-2 has an optimal effect to stimulate the size and number of multinuclear osteoclasts, expression of osteoclast genes, and resorption area. Our data also clarify that the effects caused by the increase in BMP-2 on phosphorylated SMAD levels such as c-Fos expression increased throughout the early stages of osteoclastogenesis. BMP-2 and titanium particles stimulate the expression of p-JNK, p-P38, p-IkB, and P50 compared with the titanium group. These data suggested that BMP-2 may be a crucial factor in titanium particle-mediated osteoclast formation.

  16. Investigation of surface properties of high temperature nitrided titanium alloys

    Directory of Open Access Journals (Sweden)

    E. Koyuncu

    2009-12-01

    Full Text Available Purpose: The purpose of paper is to investigate surface properties of high temperature nitrided titanium alloys.Design/methodology/approach: In this study, surface modification of Ti6Al4V titanium alloy was made at various temperatures by plasma nitriding process. Plasma nitriding treatment was performed in 80% N2-20% H2 gas mixture, for treatment times of 2-15 h at the temperatures of 700-1000°C. Surface properties of plasma nitrided Ti6Al4V alloy were examined by metallographic inspection, X-Ray diffraction and Vickers hardness.Findings: Two layers were determined by optic inspection on the samples that were called the compound and diffusion layers. Compound layer contain TiN and Ti2N nitrides, XRD results support in this formations. Maximum hardness was obtained at 10h treatment time and 1000°C treatment temperature. Micro hardness tests showed that hardness properties of the nitrided samples depend on treatment time and temperature.Practical implications: Titanium and its alloys have very attractive properties for many industries. But using of titanium and its alloys is of very low in mechanical engineering applications because of poor tribological properties.Originality/value: The nitriding of titanium alloy surfaces using plasma processes has already reached the industrial application stage in the biomedical field.

  17. Tunable functionality and toxicity studies of titanium dioxide nanotube layers

    Energy Technology Data Exchange (ETDEWEB)

    Feschet-Chassot, E.; Raspal, V.; Sibaud, Y. [Clermont Universite, Universite d' Auvergne, C-BIOSENSS, BP 10448, F-63000 Clermont Ferrand (France); Awitor, O.K., E-mail: koawitor@iut.u-clermont1.f [Clermont Universite, Universite d' Auvergne, C-BIOSENSS, BP 10448, F-63000 Clermont Ferrand (France); Bonnemoy, F. [Clermont Universite, Universite Blaise Pascal, UMR CNRS 6023, LMGE, BP 10448, F-63000 Clermont Ferrand (France); Bonnet, J.L.; Bohatier, J. [Clermont Universite, Universite Blaise Pascal, UMR CNRS 6023, LMGE, BP 10448, F-63000 Clermont Ferrand (France); Clermont Universite, Universite d' Auvergne, Laboratoire de Biologie cellulaire, BP 10448, F-63000 Clermont Ferrand (France)

    2011-02-01

    In this study, we have developed a simple process to fabricate scalable titanium dioxide nanotube layers which show a tunable functionality. The titanium dioxide nanotube layers were prepared by electrochemical anodization of Ti foil in 0.4 wt.% hydrofluoric acid solution. The nanotube layers structure and morphology were characterized using X-ray diffraction and scanning electron microscopy. The surface topography and wettability were studied according to the anodization time. The sample synthesized displayed a higher contact angle while the current density reached a local minimum. Beyond this point, the contact angles decreased with anodization time. Photo-degradation of acid orange 7 in aqueous solution was used as a probe to assess the photocatalytic activity of titanium dioxide nanotube layers under UV irradiation. We obtained better photocatalytic activity for the sample fabricated at higher current density. Finally we used the Ciliated Protozoan T. pyriformis, an alternative cell model used for in vitro toxicity studies, to predict the toxicity of titanium dioxide nanotube layers in a biological system. We did not observe any characteristic effect in the presence of the titanium dioxide nanotube layers on two physiological parameters related to this organism, non-specific esterases activity and population growth rate.

  18. Orthorhombic Titanium Matrix Composite Subjected to Simulated Engine Mission Cycles

    Science.gov (United States)

    Gabb, Timothy P.

    1997-01-01

    Titanium matrix composites (TMC's) are commonly made up of a titanium alloy matrix reinforced by silicon carbide fibers that are oriented parallel to the loading axis. These composites can provide high strength at lower densities than monolithic titanium alloys and superalloys in selected gas turbine engine applications. The use of TMC rings with unidirectional SiC fibers as reinforcing rings within compressor rotors could significantly reduce the weight of these components. In service, these TMC reinforcing rings would be subjected to complex service mission loading cycles, including fatigue and dwell excursions. Orthorhombic titanium aluminide alloys are of particular interest for such TMC applications because their tensile and creep strengths are high in comparison to those of other titanium alloys. The objective of this investigation was to assess, in simulated mission tests at the NASA Lewis Research Center, the durability of a SiC (SCS-6)/Ti-22Al-23Nb (at.%) TMC for compressor ring applications, in cooperation with the Allison Engine Company.

  19. Degradation of titanium drillpipe from corrosion and wear

    Energy Technology Data Exchange (ETDEWEB)

    Ferg, T.E.; Aldrich, C.S. (Colorado School of Mines, Golden, CO (United States)); Craig, B.D. (Metallurgical Consultants Inc., Montebello (United States))

    1993-06-01

    Drilling deeper than 35,000 ft is limited by the extreme hook loads of steel drillpipe and temperature constraints of aluminum drillpipe. Titanium Alloys Ti-6Al-4V and Beta C have been proposed for use in drillpipe for wells deeper than 35,000 ft because of their high strength/weight ratios, superior high-temperature corrosion resistance, and thermal stability. Their suitability in drilling environments, however, has not been evaluated. To determine the corrosion and wear characteristics of two types of titanium-alloy drillpipe under dogleg conditions, a test cell was constructed to test titanium drillpipe joints in contact with API Spec. 5CT Grade P-110 casing in different drilling muds. Titanium-alloy pipe and Grade P-110 casing wear rates were measured, and tests showed that both titanium-alloy pipes exhibited much greater wear than did steel drillpipe in water-based mud under the same conditions. Test data showed that the total wear rate of Alloys Ti-6Al-4V and Beta C in a drilling environment is a combination of mechanical wear and corrosion.

  20. Supercapacitance of ruthenium oxide deposited on titania and titanium substrates

    International Nuclear Information System (INIS)

    Titanium planar sheet formed by a chemical polishing process and titania nanotube array formed by an electrochemical anodization process are used as electrode substrates, on which electroactive ruthenium oxides are deposited by an electroreduction and electrooxidation process for supercapacitor applications. Morphological characterization and electrochemical properties of the electrode substrates and ruthenium oxide electrodes have been investigated. Crystalline titania nanotube array shows a much higher electric double layer capacitance than titanium planar sheet due to its high surface area of nanotube walls. Additionally, the well-defined ruthenium oxide-titania/titanium nanotube array electrode exhibits a much higher redox supercapacitance and a lower capacitance decay than ruthenium oxide/titanium planar film electrode. Such a superior energy-storage performance of ruthenium oxide-titania/titanium is ascribed to highly accessible nanotube channels for the reversible redox reaction of ruthenium oxide. The modification strategy of ruthenium oxide electrode by introducing highly ordered nanotube array structure instead of planar film structure can significantly improve specific capacitance as well as cyclic charge-discharge stability.

  1. Spectroscopic studies on Titanium ion binding to the apo lactoferrin

    International Nuclear Information System (INIS)

    Titanium is a relatively abundant element that has found growing applications in medical science and recently some of Titanium compounds are introduced as anticancer drugs. In spite of very limited data which exist on the Titanium metabolism, some proteins might be involved in the mechanism of action of Titanium up to our knowledge, there is not any report in the literature concerning binding of Titanium to apo lactoferrin. Binding of apo lactoferrin with Ti(IV)-citrate was studied by spectroflourimeterey and spectrophotometery techniques under physiological conditions. The spectroflourimeteric studies revealed a significant fluorescence quenching, that indicated binding of apo lactoferrin with Ti(IV). The same reaction was monitored through spectrophotometry technique; this represents a characteristic UV difference band at 267 nm, which is different from lac-Fe (III). Titration studies how that lactoferrin specifically binds two moles Ti(IV) as complex with citrate per mol protein. Spectroflourimeterey and spectrophotometery techniques indicated that Ti(IV) ions cause a reduction (13%-14%) in binding of Fe(III) to lactoferrin. In overall, we may come to this conclusion that this element might be involved in the iron metabolism

  2. Phospholipid polymer electrodeposited on titanium inhibits platelet adhesion.

    Science.gov (United States)

    Fukuhara, Yusuke; Kyuzo, Megumi; Tsutsumi, Yusuke; Nagai, Akiko; Chen, Peng; Hanawa, Takao

    2016-04-01

    To develop metallic materials with thromboresistance, a block-type copolymer (PMbA) was immobilized onto a titanium surface with electrodeposition. The polymer was composed of a poly(2-(methacryloyloxy)ethyl phosphorylcholine (MPC)) segment and a poly(2-aminoethylmethacrylate) segment, which was designed to electronically adsorb to the surface oxide layer on the titanium surface. We confirmed that the polymer was synthesized as expected by nuclear magnetic resonance and gel permeation chromatography. In a 0.26 mmol L(-1) PMbA solution adjusted to pH 11, -3.0 V (vs. an Ag/AgCl electrode) was applied to a titanium substrate for 300 s. The immobilization of PMbA on the titanium was confirmed with X-ray photoelectron spectroscopy and an atomic force microscope. The water contact angle and amount of adsorbed protein on the PMbA-modified surface were decreased. Thrombus formation was not observed all over the surface even when the surface was contacted with human blood without an anticoagulant. Therefore, PMbA covered the surface with even density and poly(MPC) segments in PMbA inhibited platelet adsorption. Electrodeposition with PMbA improves the blood compatibility of a titanium substrate in a simple process. PMID:25952658

  3. Biocorrosion and uptake of titanium by human osteoclasts.

    Science.gov (United States)

    Cadosch, Dieter; Al-Mushaiqri, Mohamed S; Gautschi, Oliver P; Meagher, James; Simmen, Hans-Peter; Filgueira, Luis

    2010-12-15

    All metals in contact with a biological system undergo corrosion through an electrochemical redox reaction. This study investigated whether human osteoclasts (OC) are able to grow on titanium and aluminum, and directly corrode the metals leading to the release of corresponding metal ions, which are believed to cause inflammatory reactions and activate osteoclastic differentiation. Scanning electron microscopy analysis demonstrated long-term viable OC cultures on the surface of titanium and aluminum foils. Atomic emission spectrometry investigations showed significantly increased levels of aluminum in the supernatant of OC cultured on aluminum; however, all measurements in the supernatants of cell cultures on titanium were below detection limits. Despite this, confocal microscopy analysis with Newport Green DCF diacetate ester staining depicted intense fluorescence throughout the cytoplasm and nucleolus of OC cultured on titanium foils. Comparable fluorescence intensities were not observed in monocytes and control cells cultured on glass. The present study demonstrated that human osteoclast precursors are able to grow and differentiate toward mature OC on titanium and aluminum. Furthermore, it established that the mature cells are able to directly corrode the metal surface and take up corresponding metal ions, which subsequently may be released and thereby induce the formation of osteolytic lesions in the periprosthetic bone, contributing to the loosening of the implant.

  4. Preparation of calcium carbonate particles coated with titanium dioxide

    Institute of Scientific and Technical Information of China (English)

    Hai Lin; Ying-bo Dong; Le-yong Jiang

    2009-01-01

    The preparation of a new mineral composite material, calcium carbonate particles coated with titanium dioxide, was stud-ied. The mechanism of the preparation process was proposed. The new mineral composite material was made by the mechanochemi-eal method under the optimum condition that the mass ratio of calcium carbonate particles to titanium dioxide was 6.5:3.5. The mass ratios of two different types of titanium dioxide (anatase to rutile) and grinding media to grinded materials were 8:2 and 4:1 respec-tively, and the modified density was 60%. Under this condition, the new material was capable of forming after 120-min modification.The hiding power and oil absorption of this new material were 29.12 g/m~2 and 23.30%, respectively. The results show that the modi-fication is based on surface hydroxylation. After coating with titanium dioxide, the hiding power of calcium carbonate can be im-proved greatly. The new mineral composite materials can be used as the substitute for titanium dioxide.

  5. Titanium recycling in the United States in 2004, chap. Y of Sibley, S.F., ed., Flow studies for recycling metal commodities in the United States

    Science.gov (United States)

    Goonan, Thomas G.

    2010-01-01

    As one of a series of reports that describe the recycling of metal commodities in the United States, this report discusses the titanium metal fraction of the titanium economy, which generates and uses titanium metal scrap in its operations. Data for 2004 were selected to demonstrate the titanium flows associated with these operations. This report includes a description of titanium metal supply and demand in the United States to illustrate the extent of titanium recycling and to identify recycling trends. In 2004, U.S. apparent consumption of titanium metal (contained in various titanium-bearing products) was 45,000 metric tons (t) of titanium, which was distributed as follows: 25,000 t of titanium recovered as new scrap, 9,000 t of titanium as titanium metal and titanium alloy products delivered to the U.S. titanium products reservoir, 7,000 t of titanium consumed by steelmaking and other industries, and 4,000 t of titanium contained in unwrought and wrought products exported. Titanium recycling is concentrated within the titanium metals sector of the total titanium market. The titanium market is otherwise dominated by pigment (titanium oxide) products, which generate dissipative losses instead of recyclable scrap. In 2004, scrap (predominantly new scrap) was the source of roughly 54 percent of the titanium metal content of U.S.-produced titanium metal products.

  6. The role of titanium and its alloys in the process of osseointegration

    OpenAIRE

    Neamtu, Raluca; Costea, Radu; Bucur, Mihai Bogdan; Ghita, Victor; Papakoca, Kiro; Mihai, Augustin

    2010-01-01

    Titanium and titanium-based compounds are used successfully in medical practice, especially in orthopedics and dentistry. Conferring special properties, titanium is currently one of the most important materials, with more than promising results in the osseointegration processes. Therefore, in this paper, we suggest an approach to titanium osseointegration in the medical practice. Raluca NEAMŢU1, Radu COSTEA2, Mihai-Bogdan BUCUR1, Victor GHIŢĂ1, Kiro PAPAKOCA1, Augustin MIHAI1

  7. APFIM Characterization of Grain Boundary Segregation in Titanium Carbide-Doped Molybdenum

    OpenAIRE

    Miller, M; Kurishita, H.

    1996-01-01

    The grain boundary segregation behavior of titanium and carbon have been characterized in two titanium carbide-doped molybdenum alloys. The matrix of these alloys was found to be significantly depleted in titanium, carbon, oxygen, and nitrogen. Both titanium oxycarbide and molydenum carbide precipitates were observed. The Gibbsian Interfacial Excess, Γ, determined from atom probe analyses revealed significant enrichments of carbon and nitrogen at the grain boundaries in both alloys. In atom p...

  8. Ultrahighly Dispersed Titanium Oxide on Silica : Effect of Precursors on the Structure and Photocatalysis

    OpenAIRE

    Yoshida, S.; Takenaka, S.; Tanaka, T.; Funabiki, T.

    1997-01-01

    The effect of precursor on the dispersion and catalytic performance of titanium oxide supported on silica has ben investigated. The catalysts were prepared by a simple impregnation method with three kinds of titanium complexes of different ligands (bis(isopropyato)-bis(pivaroylmethanato) : DPM, acetylacetonato : ACAC, tetrakis(isopropylato) : IPRO) with the aim of preparing ultrahighly dispersed titanium oxide on silica. The XAFS study revealed that titanium species in the catalyst prepared f...

  9. Enhanced compatibility of chemically modified titanium surface with periodontal ligament cells

    Science.gov (United States)

    Kado, T.; Hidaka, T.; Aita, H.; Endo, K.; Furuichi, Y.

    2012-12-01

    A simple chemical modification method was developed to immobilize cell-adhesive molecules on a titanium surface to improve its compatibility with human periodontal ligament cells (HPDLCs).The polished titanium disk was immersed in 1% (v/v) p-vinylbenzoic acid solution for 2 h to introduce carboxyl groups onto the surface. After rinsing with distilled deionized water, the titanium disk was dipped into 1.47% 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide solution containing 0.1 mg/ml Gly-Arg-Gly-Asp-Ser (GRGDS), human plasma fibronectin (pFN), or type I collagen from calf skin (Col) to covalently immobilize the cell-adhesive molecules on the titanium surface via formation of peptide bonds. X-ray photoelectron spectroscopy analyses revealed that cell-adhesive molecules were successfully immobilized on the titanium surfaces. The Col-immobilized titanium surface revealed higher values regarding nano rough characteristics than the as-polished titanium surface under scanning probe microscopy. The number of HPDLCs attached to both the pFN- and Col-immobilized titanium surfaces was twice that attached to the as-polished titanium surfaces. The cells were larger with the cellular processes that stretched to a greater extent on the pFN- and Col-immobilized titanium surfaces than on the as-polished titanium surface (p < 0.05). HPDLCs on the Col-immobilized titanium surfaces showed more extensive expression of vinculin at the tips of cell projections and more contiguously along the cell outline than on the as-polished, GRGDS-immobilized and pFN-immobilized titanium surfaces. It was concluded that cell-adhesive molecules successfully immobilized on the titanium surface and improved the compatibility of the surface with HPDLCs. The Col-immobilized titanium surface could be used for forming ligament-like tissues around titanium dental implants.

  10. Titanium atom detection by resonance fluorescence excited with a nitrogen laser

    International Nuclear Information System (INIS)

    Coincidence of wave lengths of nitrogen laser basing lines and resonance transitions in titanium atom is investigated. It is shown that resonance fluorescence excited by nitrogen laser can be used for absolute titanium atom density measurements. Experiments on titanium atom detection in a vapour cloud formed under irradiation of a titanium target in vacuum by dye laser pulse, are conducted. Fluorescence extinguishing is observed under high evaporation power

  11. Preparation method and use of visible light responsive nitrogen-doped titanium dioxide nano-tube

    OpenAIRE

    Jiang, Zheng; Zhu, Qingshan; Yang, Fan; Zhang, Yayuan; Li, Hongzhong

    2010-01-01

    The invention discloses a preparation method of a nitrogen-doped titanium dioxide nanotube with response to visible lights, and comprises the following steps: a. metallic titanium or titaniferous compounds are used for preparing a metatitanic acid nanotube with a hydrothermal or solvothermal method; b. the metatitanic acid or titanium dioxide nanotube that is prepared by step a or a commercial metatitanic acid or titanium dioxide nanotube is dispersed in a water solution with nitrogen sources...

  12. The potential impacts of titanium powder commoditisation on the economics of Additive Manufacturing

    OpenAIRE

    Deng, Gege

    2016-01-01

    As part of the digital manufacturing technology, Additive Manufacturing (AM) has re-ceived the special attention in fabricating titanium component in a cost-efficient fashion. However, it has been recognised that there are many issues have influenced the growth of titanium AM deployment, among which the high cost and the low availability of AM qualified titanium powder are the critical issues. Nevertheless, a novel titanium powder extraction method, the Metalysis process, promises to offer th...

  13. 77 FR 44151 - Titanium Dioxide; Exemption From the Requirement of a Tolerance

    Science.gov (United States)

    2012-07-27

    ... AGENCY 40 CFR Part 180 Titanium Dioxide; Exemption From the Requirement of a Tolerance AGENCY... from the requirement of a tolerance for residues of titanium dioxide (CAS Reg. No. 13463-67- 7) when... permissible level for residues of titanium dioxide. DATES: This regulation is effective July 27,...

  14. 40 CFR 415.220 - Applicability; description of the titanium dioxide production subcategory.

    Science.gov (United States)

    2010-07-01

    ... titanium dioxide production subcategory. 415.220 Section 415.220 Protection of Environment ENVIRONMENTAL... SOURCE CATEGORY Titanium Dioxide Production Subcategory § 415.220 Applicability; description of the titanium dioxide production subcategory. This subpart applies to discharges to waters of the United...

  15. Method for preparing hydrous titanium oxide spherules and other gel forms thereof

    Science.gov (United States)

    Collins, Jack L.

    1998-01-01

    The present invention are methods for preparing hydrous titanium oxide spherules, hydrous titanium oxide gels such as gel slabs, films, capillary and electrophoresis gels, titanium monohydrogen phosphate spherules, hydrous titanium oxide spherules having suspendible particles homogeneously embedded within to form a composite sorbent, titanium monohydrogen phosphate spherules having suspendible particles of at least one different sorbent homogeneously embedded within to form a composite sorbent having a desired crystallinity, titanium oxide spherules in the form of anatase, brookite or rutile, titanium oxide spherules having suspendible particles homogeneously embedded within to form a composite, hydrous titanium oxide fiber materials, titanium oxide fiber materials, hydrous titanium oxide fiber materials having suspendible particles homogeneously embedded within to form a composite, titanium oxide fiber materials having suspendible particles homogeneously embedded within to form a composite and spherules of barium titanate. These variations of hydrous titanium oxide spherules and gel forms prepared by the gel-sphere, internal gelation process offer more useful forms of inorganic ion exchangers, catalysts, getters and ceramics.

  16. 40 CFR 421.300 - Applicability: Description of the primary and secondary titanium subcategory.

    Science.gov (United States)

    2010-07-01

    ... primary and secondary titanium subcategory. 421.300 Section 421.300 Protection of Environment... POINT SOURCE CATEGORY Primary and Secondary Titanium Subcategory § 421.300 Applicability: Description of the primary and secondary titanium subcategory. The provisions of this subpart are applicable...

  17. Carbon-coated rutile titanium dioxide derived from titanium-metal organic framework with enhanced sodium storage behavior

    Science.gov (United States)

    Zou, Guoqiang; Chen, Jun; Zhang, Yan; Wang, Chao; Huang, Zhaodong; Li, Simin; Liao, Hanxiao; Wang, Jufeng; Ji, Xiaobo

    2016-09-01

    Carbon-coated rutile titanium dioxide (CRT) was fabricated through an in-situ pyrolysis of titanium-based metal organic framework (Ti8O8(OH)4[O2CC6H4CO2]6) crystals. Benefiting from the Tisbnd Osbnd C skeleton structure of titanium-based metal organic framework, the CRT possesses abundant channels and micro/mesopores with the diameters ranging from 1.06 to 4.14 nm, shows larger specific surface area (245 m2 g-1) and better electronic conductivity compared with pure titanium dioxide (12.8 m2 g-1). When applied as anode material for sodium-ion batteries, the CRT electrode exhibits a high cycling performance with a reversible capacity of ∼175 mAh g-1 at 0.5 C-rate after 200 cycles, and obtains an excellent rate capability of ∼70 mAh g-1 after 2000 cycles even at a specific current of 3360 mA g-1(20 C-rate). The outstanding rate capability can be attributed to the carbon-coated structure, which may effectively prevent aggregation of the titanium dioxide nanoparticles, accelerate the mass transfer of Na+ and speed up the charge transfer rate. Considering these advantages of this particular framework structure, the CRT can serve as an alternative anode material for the industrial application of SIBs.

  18. Manufacturing of composite titanium-titanium nitride coatings by reactive very low pressure plasma spraying (R-VLPPS)

    International Nuclear Information System (INIS)

    Very Low Pressure Plasma Spraying (VLPPS) is an emerging spray process nowadays intensively studied by many research centers in the World. To date, studies are mostly focused on the manufacturing of ceramic or metallic coatings. None refers to composite coatings manufacturing by reactive plasma spraying under very low pressure (i.e., ∼150 Pa). This paper aims at presenting the carried-out developments and some results concerning the manufacturing of composite coatings by reactive spraying. Titanium was selected as metallic material in order to deposit titanium-nitride titanium coatings (Ti-TiN). Nitrogen was used as plasma gas and was injected along an Ar-H2-N2 plasma jet via a secondary injector in order to reach the nitrogen content on the substrate surface. Thus, different kind of reactive mechanisms were highlighted. Resulting coatings were characterized by Scanning Electron Microscopy (SEM) observations. Porous microstructures are clearly identified and the deposits exhibit condensed vapours and molten particles. Glow Discharge Optical Emission Spectroscopy (GDOES) analysis evidenced nitrogen inside the deposits and X-Ray Diffraction (XRD) analysis confirmed the formation of titanium nitride phases, such as TiN and Ti2N, depending upon the location of the nitrogen injection. Microhardness values as high as 800 VHN were measured on manufactured samples (to be compared to 220 VHN for pure titanium VLPPS-manufactured coatings)

  19. Discoloration and dissolution of titanium and titanium alloys with immersion in peroxide- or fluoride-containing solutions.

    Science.gov (United States)

    Noguchi, Tatsumi; Takemoto, Shinji; Hattori, Masayuki; Yoshinari, Masao; Kawada, Eiji; Oda, Yutaka

    2008-01-01

    This study compared differences in discoloration and dissolution in several titanium alloys with immersion in peroxide- or fluoride-containing solution. Commercially pure titanium (CP-Ti) and six titanium-based alloys were used: Ti-0.15Pd, Ti-6Al-4V, Ti-7Nb-6Al, Ti-55Ni, Ti-10Cu, and Ti-20Cr. Two test solutions were prepared for immersion of polished titanium and titanium alloys: one consisting of 0.2% NaF + 0.9% NaCl (pH 3.8 with lactic acid) and the other of 0.1 mol/l H2O2 + 0.9% NaCl (pH 5.5). Following immersion, color changes were determined with a color meter and released elements were measured using ICP-OES. Discoloration and dissolution rates differed between the two solutions. In the hydrogen peroxide-containing solution, color difference was higher in Ti-55Ni and Ti-6Al-4V than in any of the other alloys, and that Ti-55Ni showed the highest degree of dissolution. In the acidulated fluoride-containing solution, CP-Ti, Ti-0.15Pd, Ti-6Al-4V, Ti-7Nb-6Al, and Ti-10Cu alloys showed remarkable discoloration and dissolution with immersion. On the contrary, Ti-20Cr alloy showed very little discoloration and dissolution in either solution.

  20. Preparation and properties of biomedical porous titanium alloys by gelcasting.

    Science.gov (United States)

    Yang, Donghua; Shao, Huiping; Guo, Zhimeng; Lin, Tao; Fan, Lianpeng

    2011-08-01

    Porous titanium alloys have been prepared by gelcasting in this study. The elastic solid green body was first polymerized and then vacuum sintered to porous titanium alloys with low contamination by controlling sintering conditions. The microstructure and the total porosity of the vacuum sintered porous Ti-Co and Ti-Mo alloys were analyzed by using scanning electron microscopy and x-ray diffraction. Moreover, compression and bending tests were conducted to investigate their mechanical properties. The results show that open and closed three-dimensional pore morphologies and total porosity ranging from 38.34% to 58.32% can be achieved. In contrast to porous Ti by gelcasting, the compression and bending strengths of porous titanium alloys were significantly increased by adding Mo and Co with Young's modulus ranging between 7-25 GPa, which is close to that of human cortical bone, therefore being suited for potential application in load-bearing implants.