WorldWideScience

Sample records for ccqm-k30 international comparison

  1. Determination of lead in red wine for CCQM-K30 international comparison by using ID-ICPMS

    International Nuclear Information System (INIS)

    Zhou Tao; Wang Jun; Lu Hai; Zhao Motian

    2007-01-01

    The content of lead in red wine for CCQM-K30 international key comparison is determined by using isotope dilution mass spectrometry (IDMS). This test almost reach detect limit of the method because the content of lead in red wine was only 3 ng/g and the procedure blank was about 0.3 ng. The comparison results indicate that it is easy to achieve agreements using IDMS. In uncertainty analysis, all of the factors about IDMS method were considered. But, procedure blank took great inference to experiment precision and enlarged the total uncertainty. Therefore the controls of procedure blank were very important for the analysis of ultra-trace concentration of samples. (authors)

  2. CCQM key comparison CCQM-K75: Determination of toxic metals in algae

    Science.gov (United States)

    Shakhashiro, A.; Toervenyi, A.; Gaudino, S.; Rosamilia, S.; Belli, M.; Turk, G. C.

    2011-01-01

    The determination of mass fraction of toxic elements and especially platinum emitted from automobile catalytic converters in the air is a critical factor in assessing air quality and the potential impact of possible pollutants. Air is in fact one of the main pathways for human exposure to toxic elements. Biomonitors, such as lichen and algae, are examples of environmental samples that have been widely used by the scientific community to assess and monitor the level of environmental pollution. For this purpose, the IAEA-450 algae material containing heavy metals and platinum at low level was prepared by IAEA Seibersdorf Laboratories in collaboration with the Italian National Institute for Environmental Protection—ISPRA (former APAT). During the April meeting in 2009 of the Inorganic Analysis Working Group (IAWG) of the CCQM it was agreed to organize a key comparison K75 for Pt and Ni and a parallel pilot study P118 for As, Cd, Cr, Hg, Ni, Pb and Pt using this algae material. The key comparison CCQM-K75 was successfully organized. The participating NMIs demonstrated a high level of measurement capabilities and technical competence in analysing nickel and platinum at a low level of concentration in environmental samples such as algae. The between-laboratories reproducibility standard deviation for nickel and platinum was 1.9% and 3.6% respectively, which reflects an excellent agreement of between-laboratories measurement results. The ratio between the bias and its expanded uncertainty for nickel and platinum was below 2.0 for all reported results except in one case. This study was a practical demonstration of a CCQM comparison to use the 'core-capabilities' utilized by participants as a mean of providing evidence for Calibration and Measurement Capabilities (CMC) claims for Ni and Pt. Based on this CCQM international key comparison, the measurement capability of the NMIs which participated in the CCQM-K75 has been demonstrated directly for determination of Pt and Ni

  3. CCQM-K11.2 determination of glucose in human serum and CCQM-K12.2 determination of creatinine in human serum

    Science.gov (United States)

    Wise, Stephen A.; Phinney, Karen W.; Duewer, David L.; Sniegoski, Lorna T.; Welch, Michael J.; Pritchett, Jeanita; Pabello, Guiomar; Avila Calderon, Marco A.; Balderas, Miryan; Qinde, Liu; Kooi, Lee Tong; Rego, Eliane; Garrido, Bruno; Allegri, Gabriella; de La Cruz, Marcia; Barrabin, Juliana; Monteiro, Tânia; Lee, Hwashim; Kim, Byungjoo; Delatour, Vincent; Peignaux, Maryline; Kawaguchi, Migaku; Bei, Xu; Can, Quan; Nammoonnoy, Jintana; Schild, Katrin; Ohlendorf, Rüdiger; Henrion, Andre; Ceyhan Gören, Ahmet; Yılmaz, Hasibe; Bilsel, Mine; Konopelko, L.; Krylov, A.; Lopushanskaya, E.

    2018-01-01

    Glucose and creatinine are two of the most frequently measured substances in human blood/serum for assessing the health status of individuals. Because of their clinical significance, CCQM-K11 glucose in human serum and CCQM-K12 creatinine in human serum were the fourth and fifth key comparisons (KCs) performed by the Organic Analysis Working Group (OAWG). These KCs were conducted in parallel and were completed in 2001. The initial subsequent KCs for glucose, CCQM-K11.1, and creatinine, CCQM-K12.1, were completed in 2005. Measurements for the next KCs for these two measurands, CCQM-K11.2 and CCQM-K12.2, were completed in 2013. While designed as subsequent KCs, systematic discordances between the participants' and the anchor institution's results in both comparisons lead the OAWG to request reference results from two experienced laboratories that had participated in the 2001 comparisons. Based on the totality of the available information, the OAWG converted both CCQM-K11.2 and CCQM-K12.2 to 'Track C' KCs where the key comparison reference value is estimated by consensus. These comparisons highlighted that carrying out comparisons for complex chemical measurements and expecting to be able to treat them under the approaches used for formal CIPM subsequent comparisons is not an appropriate strategy. The approach used here is a compromise to gain the best value from the comparison; it is not an approach that will be used in the future. Instead, the OAWG will focus on Track A and Track C comparisons that are treated as stand-alone entities. Participation in CCQM-K11.2 demonstrates a laboratory's capabilities to measure a polar (pKow > 2), low molecular mass (100 g/mol to 500 g/mol) metabolite in human serum at relatively high concentrations (0.1 mg/g to 10 mg/g). Participation in CCQM-K12.2 demonstrates capabilities to measure similar classes of metabolites at relatively low concentrations (1 μg/g to 30 μg/g). The capabilities required for the analysis of complex

  4. KEY COMPARISON: Final report on CCQM-K9.2: Subsequent key comparison on pH determination of phosphate buffer by Harned cell measurements

    Science.gov (United States)

    Spitzer, Petra; Giera, Janine; Fraga, Isabel C.; Tønnes Jakobsen, Pia; Jensen, Hans D.; Hyllested, Peter; Karpov, Oleg; Kutovoy, Viatcheslav; Nakamura, Susumu; Vospelova, Alena; Zvezdina, Valentina

    2008-01-01

    CCQM-K9.2 was performed supplementary to the key comparison CCQM-K9 on the pH determination of a phosphate buffer with nominal pH ~ 6.9 (at 25 °C). The sample composition was very similar in both comparisons. Only the source of the starting material used for sample preparation was different. The comparison was restricted to the use of the primary method for pH (Harned cell measurement) as defined in the IUPAC Recommendations [2]. The measurement temperatures were 15 °C, 25 °C, 37 °C. CCQM-K9.2, CCQM-K.9 and the first supplementary comparison CCQM-K9.1 [5] are activities of the Electrochemical Working Group (EAWG) of the CCQM. All three comparisons were coordinated by the PTB, Germany. The Danish Primary Laboratory (DPL) successfully took part in the CCQM-K9. Meanwhile the primary set-up for pH in Denmark moved from DPL affiliated to Radiometer Medical to DFM, Denmark. The subsequent comparison allows assessing the degree of equivalence for the measurement of pH at DFM after the move. Due to the interest of other laboratories in demonstrating their progress in pH measurements on the primary level the CCQM-K9.2 supplementary comparison was extended to other participants than DFM, namely NMIJ, VNIIFTRI, INMETRO and CMI. The reported quantity for CCQM-K9.2 was not the pH of the sample but the acidity function at zero chloride molality (see chapter 12). To calculate the pH value from the acidity function it is necessary to know the ionic strength of the sample buffer solution, which was undisclosed by the coordinator. With the exception of the Czech Metrology Institute, CMI, good agreement in the determined acidity function is found between the participants. The results reported by DFM and by PTB agree within their measurement uncertainty at all measurement temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report

  5. KEY COMPARISON: Key comparison CCQM-K60: Total selenium and selenomethionine in selenised wheat flour

    Science.gov (United States)

    Goenaga Infante, Heidi; Sargent, Mike

    2010-01-01

    Key comparison CCQM-K60 was performed to assess the analytical capabilities of national metrology institutes (NMIs) to accurately quantitate the mass fraction of selenomethionine (SeMet) and total selenium (at low mg kg-1 levels) in selenised wheat flour. It was organized by the Inorganic Analysis Working Group (IAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) as a follow-up key comparison to the previous pilot study CCQM-P86 on selenised yeast tablets. LGC Limited (Teddington, UK) and the Institute for National Measurement Standards, National Research Council Canada (NRCC, Ottawa, Canada) acted as the coordinating laboratories. CCQM-K60 was organized in parallel with a pilot study (CCQM-P86.1) involving not only NMIs but also expert laboratories worldwide, thus enabling them to assess their capabilities, discover problems and learn how to modify analytical procedures accordingly. Nine results for total Se and four results for SeMet were reported by the participant NMIs. Methods used for sample preparation were microwave assisted acid digestion for total Se and multiple-step enzymatic hydrolysis and hydrolysis with methanesulfonic acid for SeMet. For total Se, detection techniques included inductively coupled plasma mass spectrometry (ICP-MS) with external calibration, standard additions or isotope dilution analysis (IDMS); instrumental neutron activation analysis (INAA); and graphite furnace atomic absorption spectrometry (GFAAS) with external calibration. For determination of SeMet in the wheat flour sample, the four NMIs relied upon measurements using species-specific IDMS (using 76Se-enriched SeMet) with HPLC-ICP-MS. Eight of the nine participating NMIs reported results for total Se within 3.5% deviation from the key comparison reference value (KCRV). For SeMet, the four participating NMIs reported results within 3.2% deviation from the KCRV. This shows that the performance of the majority of the CCQM-K60 participants was very good

  6. KEY COMPARISON: CCQM-K27-Subsequent: Key Comparison (subsequent) for the determination of ethanol in aqueous matrix

    Science.gov (United States)

    Schantz, Michele M.; Duewer, David L.; Parris, Reenie M.; May, Willie E.; Archer, Marcellé; Mussell, Chris; Carter, David; Konopelko, Leonid A.; Kustikov, Yury A.; Krylov, Anatoli I.; Fatina, Olga V.

    2005-01-01

    Ethanol is important both forensically ('drunk driving' or driving while under the influence, 'DWI', regulations) and commercially (alcoholic beverages). Blood- and breath-alcohol testing can be imposed on individuals operating private vehicles such as cars, boats, or snowmobiles, or operators of commercial vehicles like trucks, planes, and ships. The various levels of blood alcohol that determine whether these operators are considered legally impaired vary depending on the circumstances and locality. Accurate calibration and validation of instrumentation is critical in areas of forensic testing where quantitative analysis directly affects the outcome of criminal prosecutions, as is the case with the determination of ethanol in blood and breath. Additionally, the accurate assessment of the alcoholic content of beverages is a commercially important commodity. In 2002, the CCQM conducted a Key Comparison (CCQM-K27) for the determination of ethanol in aqueous matrix with nine participants. A report on this project has been approved by the CCQM and can be found at the BIPM website and in this Technical Supplement. CCQM-K27 comprised three samples, one at low mass fraction of ethanol in water (nominal concentration of 0.8 mg/g), one at high level (nominal concentration of 120 mg/g), and one wine matrix (nominal concentration of 81 mg/g). Overall agreement among eight participants using gas chromatography with flame ionization detection (GC-FID), titrimetry, isotope dilution gas chromatography/mass spectrometry (GC-IDMS), and gas chromatography-combustion-isotope ratio mass spectrometry (ID-GC-C-IRMS) was good. The ninth participant used a headspace GC-FID method that had not been validated in an earlier pilot study (CCQM-P35). A follow-on Key Comparison, CCQM-K27-Subsequent, was initiated in 2003 to accommodate laboratories that had not been ready to benchmark their methods in the original CCQM-K27 study or that wished to benchmark a different method. Four levels of

  7. Contaminant and other elements in soil (CCQM-K127)

    Science.gov (United States)

    Rocio Arvizu Torres, M.; Manzano, J. Velina Lara; Valle Moya, Edith; Horvat, Milena; Jaćimović, Radojko; Zuliani, Tea; Vreča, Polona; Acosta, Osvaldo; Bennet, John; Snell, James; Almeida, Marcelo D.; de Sena, Rodrigo C.; Dutra, Emily S.; Yang, Lu; Li, Haifeng

    2017-01-01

    by their available analytical methods. This facilitated the investigation into the core capabilities of participants to measure the mass fraction of tested elements in soil and therefore to claim their CMCs as listed in appendix C of the key comparison database (KCDB) under the mutual recognition arrangement of the International Committee for Weights and Measures (CIPM MRA). In total 19 institutes (NMIs/Dis) participated in the key comparison and the reported results of the key comparison were from 18 institutes (NMIs/DIs); 151 measurements were reported for CCQM-K127. The analytical techniques selected by the participant institutes were ICP-MS, ICP-OES, FAAS, ET-AAS and INAA (k0-method of INAA); the sample preparation methods used were based on microwave assisted digestion, except when it was used INAA. After discussions it agreed to use the median as KCRV and the MMADe as u(xKCRV). Generally most of the results of the participants were found to be consistent for all measurements according to their equivalence statements, with the exception of some extreme values, which were identified with a value of di/U(di) higher than 1. This key comparison is a means of providing evidence for practical demonstration of a CCQM comparison calibration and measurement capabilities (CMCs) claims for contaminant and others elements, in low and medium content levels in non-contaminated and contaminated matrices described in category 13. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. International comparison CCQM-K119 liquefied petroleum gas

    Science.gov (United States)

    Brewer, P. J.; Downey, M. L.; Atkins, E.; Brown, R. J. C.; Brown, A. S.; Zalewska, E. T.; van der Veen, A. M. H.; Smeulders, D. E.; McCallum, J. B.; Satumba, R. T.; Kim, Y. D.; Kang, N.; Bae, H. K.; Woo, J. C.; Konopelko, L. A.; Popova, T. A.; Meshkov, A. V.; Efremova, O. V.; Kustikov, Y.

    2018-01-01

    Liquefied hydrocarbon mixtures with traceable composition are required in order to underpin measurements of the composition and other physical properties of LPG (liquefied petroleum gas), thus meeting the needs of an increasingly large industrial market. This comparison aims to assess the analytical capabilities of laboratories for measuring the composition of a Liquid Petroleum Gas (LPG) mixture when sampled in the liquid phase from a Constant Pressure Cylinder. Mixtures contained ethane, propane, propene, i-butane, n-butane, but-1-ene and i-pentane with nominal amount fractions of 2, 71, 9, 4, 10, 3 and 1 cmol mol-1 respectively. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. PILOT STUDY: An international comparison of mass fraction purity assignment of theophylline: CCQM Pilot Study CCQM-P20.e (Theophylline)

    Science.gov (United States)

    Westwood, S.; Josephs, R.; Daireaux, A.; Wielgosz, R.; Davies, S.; Kang, M.; Ting, H.; Phillip, R.; Malz, F.; Shimizu, Y.; Frias, E.; Pérez, M.; Apps, P.; Fernandes-Whaley, M.; DeVos, B.; Wiangnon, K.; Ruangrittinon, N.; Wood, S.; Duewer, D.; Schantz, M.; Bedner, M.; Hancock, D.; Esker, J.

    2009-01-01

    Under the auspices of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a laboratory comparison, CCQM-P20.e, was coordinated by the Bureau International de Poids et Mesures (BIPM) in 2006/2007. Nine national measurement institutes, two expert laboratories and the BIPM participated in the comparison. Participants were required to assign the mass fraction of theophylline present as the main component in two separate study samples (CCQM-P20.e.1 and CCQM-P20.e.2). CCQM-P20.e.1 consisted of a high-purity theophylline material obtained from a commercial supplier. CCQM-P20.e.2 consisted of theophylline to which known amounts of the related structure compounds theobromine and caffeine were added in a homogenous, gravimetrically controlled fashion. For the CCQM-P20.e.2 sample it was possible to estimate gravimetric reference values both for the main component and for the two spiked impurities. In addition to assigning the mass fraction content of theophylline for both materials, participants were requested but not obliged to provide mass fraction estimates for the minor components they identified in each sample. The results reported by the study participants for the mass fraction content of theophylline in both materials showed good levels of agreement both with each other and with the gravimetric reference value assigned to the CCQM-P20.e.2 material. There was also satisfactory agreement overall, albeit at higher levels of uncertainty, in the quantification data reported for the minor components present in both samples. In the few cases where a significant deviation was observed from the consensus values reported by the comparison participants or gravimetric reference values where these where available, they appeared to arise from the use of non-optimal chromatographic separation conditions. The results demonstrate the feasibility for laboratories to assign mass fraction content with associated absolute expanded

  10. KEY COMPARISON: Final report on CCQM-K63.a,b: Non-peptide hormones in serum: cortisol and progesterone

    Science.gov (United States)

    S-C Tai, Susan; Duewer, David L.

    2010-01-01

    Hormones are chemical messengers that regulate many life functions. Deviations from normal hormone levels can have serious health consequences. Accurate measurement of hormone levels in serum can be beneficial in diagnosing, monitoring, and treating a number of diseases. Two steroid hormones, cortisol and progesterone, were selected by the Organic Analysis Working Group (OAWG) to evaluate its member Institutes' measurement capabilities for this important class of measurand. Serum concentrations of cortisol range from 30 ng/mL to 230 ng/mL. Serum concentrations of progesterone in adult females range from 0.15 ng/mL to 25 ng/mL but can rise to approx230 ng/mL during pregnancy. The ability to measure cortisol is indicative of a laboratory's ability to measure steroid hormones at concentration levels similar to cortisol. The ability to measure progesterone is indicative of a laboratory's ability to measure steroid hormones with similar functional groups and concentration levels, such as testosterone. Pilot studies CCQM-P77.a and CCQM-P77.b on the determination of cortisol and progesterone in human serum were completed in 2006. There was good agreement among the results reported by participants who used isotope dilution/mass spectrometry (ID/MS) with either gas chromatography (GC) or liquid chromatography (LC). In 2007 the OAWG decided to proceed with key comparison (KC) CCQM-K63.a, cortisol in human serum, and CCQM-K63.b, progesterone in human serum. Thus, following established OAWG procedure, only results from participants that (1) used an ID/MS-based method, (2) participated in the relevant pilot study, and (3) used a metrologically traceable primary standard were to be eligible for use in calculating the key comparison reference value (KCRV) for each measurand. Six laboratories participated in CCQM-K63.a and eight laboratories participated in CCQM-K63.b. The same pooled frozen female serum material was used in both of the KCs. The mean value for the six ID

  11. CCQM K6.2 determination of total cholesterol in human serum

    Science.gov (United States)

    Wise, Stephen A.; Phinney, Karen W.; Duewer, David L.; Sniegoski, Lorna T.; Welch, Michael J.; Pabello, Guiomar; Avila Caldero, Marco A.; Qinde, Liu; Kooi, Lee Tong; Rego, Eliane; Garrido, Bruno; Allegri, Gabriella; de La Cruz, Marcia; Barrabin, Juliana; Puglisi, Celia; Lopez, Eduardo; Lee, Hwashim; Kim, Byungjoo; Delatour, Vincent; Heuillet, Maud; Nammoonnoy, Jintana; Ceyhan Gören, Ahmet; Bilsel, Gokhan; Konopelko, L.; Krylov, A.; Lopushanskaya, E.

    2018-01-01

    Cholesterol is one of the most frequently measured substances in human blood/serum to assist in assessing the health status of individuals. Because of its clinical significance, CCQM-K6 determination of cholesterol in serum was completed in 2000 as one of the first key comparison (KC) studies performed within the Organic Analysis Working Group (OAWG). The first subsequent KC for cholesterol, CCQM-K6.1, was completed in 2001. Measurements for this second subsequent, CCQM-K6.2, were completed in 2012. These subsequent comparisons were conducted to enable CCQM members that had not participated in earlier studies to demonstrate their capabilities to measure a nonpolar (pKow mass (100 g/mol to 500 g/mol) metabolite in human serum at relatively high concentrations (1 mg/g to 3 mg/g) found in normal populations. Successful participation in CCQM-K6.2 demonstrated capabilities in analysis of complex biological matrices including sample preparation (extraction, derivatization), LC or GC separation, and quantification using an isotope dilution mass spectrometry approach. Normally in a subsequent KC, no key comparison reference value (KCRV) would be established and assessment of performance would be via the deviation of participants' results to the anchor institute's results, adjusted to account for the anchor's performance in the original comparison versus its KCRV. Due to the very long-time period since the original key comparison, the OAWG decided that this did not represent the best approach to assess performance in what is a relatively complex measurement. Given the excellent agreement between the anchor institute's results and robust consensus summary of the participants' values, the reference value for this study was taken as the anchor institute's result and treated as a 'KCRV'. Seven of the nine participants demonstrated agreement with the reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears

  12. Elements in human serum—CCQM-K139

    Science.gov (United States)

    Shin, Richard; Dewi, Fransiska; Tong, Benny; Wah, Leung Ho; Saxby, David; Armishaw, Paul; Ivanova, Veronika; Feng, Liuxing; Wang, Jun; Estela del Castillo Busto, M.; Fisicaro, Paola; Rienitz, Olaf; Fung, Wai-Hong; Ho-pan Yau, Michael; Yim, Yong-Hyeon; Buzoianu, Mirella; Can, Suleyman Z.; Ari, Betul; Cankur, Oktay; Goenaga Infante, Heidi; Pérez-Zambra, Ramiro; Ferreira, Elizabeth; Long, Stephen

    2018-01-01

    Elements in human serum serve as important biomarkers and their levels reflect the well-being of an individual. Electrolytes such as sodium (Na) and chloride (Cl) are crucial in maintaining the normal distribution of water, osmotic pressure and electrical neutrality in the body. Trace element such as copper (Cu) plays a part in many oxidation-reduction reactions and metalloenzymes. The majority of selenium (Se) exists as selenoproteins which are cofactors in the glutathione peroxidase activity that protects the body against free radicals. Phosphorus (P) is required for strong bones and teeth. It is also indispensable for growth, maintenance and repair of tissues and cells. The key comparison CCQM-K139: elements in human serum was coordinated by the Health Sciences Authority, Singapore. This comparison aimed to enable participating National Metrology Institutes (NMIs) and Designated Institutes (DIs) to demonstrate their competence in the determination of elements (electrolytes and essential elements) in human serum. The five measurands (Na, Cl, Cu, Se and P) selected for this comparison were not covered in the last two comparisons in the clinical area (CCQM-K14 and CCQM-K107) and offered different analytical challenges. Their concentration levels were within the normal biological range. They were also within the range of existing calibration and measurement capability (CMC) claims in the International Bureau of Weights and Measures' Key Comparison Database (BIPM KCDB). Ten institutes participated in the comparison for Na, eight for Cl, eleven for Cu, six for Se and eight for P. For the analysis of Na, Cu, Se and P, most of the participating institutes employed microwave-assisted digestion and acid digestion (with or without heating) sample dissolution. For the analysis of Cl, in addition to the microwave-assisted digestion and acid digestion, a wider variety of techniques were employed. These included matrix separation, alkaline extraction and coulometric titration

  13. Final report on CCQM-K9.2 : subsequent key comparison on pH determination of phosphate buffer by Harned cell measurements

    OpenAIRE

    Spitzer, Petra; Giera, Janine; Fraga, Isabel Cristina Serta; Jakobsen, Pia Tonnes; Jensen, Hans D.; Hyllested, Peter; Karpov, Oleg; Kutovoy, Viatcheslav; Nakamura, Susumu; Vospelova, Alena; Zvezdina, Valentina

    2008-01-01

    CCQM-K9.2 was performed supplementary to the key comparison CCQM-K9 [1] on the pH determination of a phosphate buffer with nominal pH ~ 6.9 (at 25 °C). The sample composition was very similar in both comparisons. Only the source of the starting material used for sample preparation was different. The comparison was restricted to the use of the primary method for pH (Harned cell measurement) as defined in the IUPAC Recommendations [2]. The measurement temperatures were15 °C, 25 °C , 37...

  14. Final report on CCQM-K27.2: Second Subsequent study: determination of ethanol in aqueous media

    Science.gov (United States)

    Schantz, Michele M.; Parris, Reenie M.; May, Willie E.; Rosso, Adriana; Puglisi, Celia; Marques Rodrigues Caixeiro, Janaína; Massiff, Gabriela; Camacho Frías, Evangelina; Pérez Urquiza, Melina; Archer, Marcellé; Visser, M. S.; deVos, Betty-Jayne

    2013-01-01

    Ethanol is important both forensically ('drunk driving' or driving while under the influence, 'DWI', regulations) and commercially (alcoholic beverages). Blood- and breath-alcohol testing can be imposed on individuals operating private vehicles such as cars, boats or snowmobiles, or operators of commercial vehicles like trucks, planes and ships. The various levels of blood alcohol that determine whether these operators are considered legally impaired vary depending on the circumstances and locality. Accurate calibration and validation of instrumentation is critical in areas of forensic testing where quantitative analysis directly affects the outcome of criminal prosecutions, as is the case with the determination of ethanol in blood and breath. Additionally, the accurate assessment of the alcoholic content of beverages is a commercially important commodity. In 2002, the CCQM conducted a key comparison (CCQM-K27) for the determination of ethanol in aqueous matrix with nine participants. A report on this project has been approved by the CCQM and can be found at the BIPM website. CCQM-K27 comprised three samples, one at low mass fraction of ethanol in water (nominal concentration of 0.8 mg/g), one at high level (nominal concentration of 120 mg/g) and one wine matrix (nominal concentration of 81 mg/g). Overall agreement among eight participants using gas chromatography with flame ionization detection (GC-FID), titrimetry, isotope dilution gas chromatography/mass spectrometry (GC-IDMS) and gas chromatography-combustion-isotope ratio mass spectrometry (ID-GC-C-IRMS) was good. The ninth participant used a headspace GC-FID method that had not been validated in an earlier pilot study (CCQM-P35). A follow-on key comparison, CCQM-K27-Subsequent, was initiated in 2003 to accommodate laboratories that had not been ready to benchmark their methods in the original CCQM-K27 study or that wished to benchmark a different method. Four levels of ethanol in water were used in the

  15. Final report for CCQM-K107: total elements and selenomethionine in human serum

    Science.gov (United States)

    Goenaga Infante, Heidi

    2016-01-01

    Routine tests that measure the concentration of electrolytes in serum are needed for diagnosis and management of renal, endocrine, acid-base, water balance and other conditions such as screening D- and A-vitamin disorders, kidney insufficiency, bone diseases and leukaemia. The diagnostic concentration ranges for many such markers are narrow, requiring reference methods with small uncertainty. Serum concentration of total selenium (Se) is important in health studies but there is increasing interest in the speciation of selenium compounds in clinical samples such as serum and individual Se- Species are bio-indicators of Se status. The last CCQM IAWG key comparison for elements in the clinical area (CCQM-K14: Ca in human serum) was organized in 2003 and the previous key comparison (CCQM-K60) for Se and Se species used a wheat flour sample. Therefore, the CCQM IAWG agreed that CCQM-K107 and a parallel pilot study CCQM-P146 should be carried out. The candidate human serum sample used for both CCQM-K107 and P146 is of high complexity and contains approximately 1000-fold lower concentrations of selenium methionine (SeMet) than those encountered in the CCQM-K60 wheat flour. This significantly broadens the scope and degree of difficulty of earlier measurements in this field. A total of eleven institutes participated in CCQM-K107 (11 participants for total elements and 7 for SeMet). The performance of the majority of the K107 participants for all the measurands was very good, illustrating their ability to obtain accurate results for analytes such as electrolytes at mg kg-1 level, essential elements at µg kg-1 level and selenium species at µg kg-1 level in a complex biological fluid. The range of agreement between participants was within the interval of ± 0.1% for Ca and up to ± 1.8% for Fe. CMC claims based on total elements in this study may include other elements with similar core competencies (e.g. Se, Cu, Zn) in a wide range of biological materials (including liquids

  16. KEY COMPARISON: Final report on CCQM-K62: Nutrients in infant/adult formula—Vitamins

    Science.gov (United States)

    Sharpless, Katherine E.; Rimmer, Catherine A.; Phinney, Karen W.; Nelson, Bryant C.; Duewer, David L.; Wise, Stephen A.; Kim, Byungjoo; Liu, Jun; Huang, Ting; Zhang, Wei

    2010-01-01

    Key comparison CCQM-K62 was designed to enable demonstration of the equivalence in capabilities for measurement of vitamins in a food matrix. A milk-based fortified human infant/adult formula was selected as the matrix based upon material availability and relevance. Because vitamins were added to the CCQM-K62 study material in a single form and at levels significantly higher than those that would be naturally occurring in the milk base, the ability of a laboratory to measure the study vitamins is only indicative of a laboratory's ability to measure vitamins in fortified foods. Target analytes were selected for study because of the ready availability of suitable standard materials and the range of their chemical properties: folic acid (vitamin B9) is a single water-soluble molecular entity that typically occurs at low levels and can be unstable, niacin (vitamin B3) is a single stable molecular entity and is typically present at higher concentrations than the other water-soluble vitamins, vitamin A has multiple molecular forms (including retinol and retinyl palmitate), is fat-soluble and typically occurs at relatively high levels. Results for participants measuring only folic acid or niacin are only indicative of their ability to make that measurement; results for participants measuring both folic acid and niacin are indicative of a laboratory's ability to measure folic acid, thiamine, niacin, and riboflavin in fortified foods but not vitamin C or other water-soluble vitamins. The ability to measure vitamin A (reported as retinol equivalents) in this material is also indicative of the participant's ability to measure vitamin E (as alpha-tocopherol and alpha-tocopheryl acetate) but is not indicative of the ability to measure vitamins D and K, which typically occur at much lower concentrations. The relative degrees of equivalence of the reported measurements for all three analytes in CCQM-K62 were within 10%; however, since only two results were submitted for niacin

  17. Final report of the key comparison CCQM-K106: Pb, As and Hg measurements in cosmetic (cream)

    Science.gov (United States)

    Wang, Jun; Wang, Qian; Yamani, Randa Nasr Ahmed; Shehata, Adel B.; Jacimovic, Radojko; Pavlin, Majda; Horvat, Milena; Tsoi, Y. P.; Tsang, C. K.; Shin, Richard; Chailap, Benjamat; Yafa, Charun; Caciano de Sena, Rodrigo; de Almeida, Marcelo; Yim, Yong-Hyeon; Lee, Kyoung-Seok; Heun Kim, Sook; Konopelko, Leonid; Ari, Betül; Tokman, Nilgün; Rienitz, Olaf; Jaehrling, Reinhard; Pape, Carola

    2015-01-01

    Cosmetics are used in practically all walks of life as a means of improving skin and beautifying complexion. In recent years, more and more attention has been paid to the cosmetic safety. In response to the cosmetic safety issue, the accurate measurement of the heavy metals in cosmetics is, therefore, particularly important. NMIs from different countries should establish their chemical metrology traceability system in this area, which includes both measurement methods research and certain CRMs development. It should be noted that because the matrix of many cosmetics is complex and the contents of the heavy metals are relatively low, it still is a challenging task to measure the analytes with high accuracy and precision. CCQM-K106 followed up CCQM pilot study 'CCQM-P128: Pb, As measurements in cosmetic (cream)' coordinated by the National Institute of Metrology, China (NIM) in 2009. The cream was selected as the testing material, which is widely used as a daily skin care worldwide. This is the first CCQM key comparison regarding the measurement of toxic metal elements with the cosmetic matrix, which includes pure water, liquid paraffin, silicone oil, synthetic squalane, hyaluronic acid, glycerin, propylene glycol, allantoin, preservative and so on. The aim of the CCQM-K106 is to demonstrate the capability of participating NMIs and designated institutes in measuring the contents of poisonous elements, including lead, arsenic and mercury in a cosmetic sample (cream), and support CMC claims relating to inorganic elements in cosmetic materials and similar chemical industry products. The cream matrix sample was prepared under the guidance of professional technicians. The formula of the cream was carefully chosen to match with a real cosmetic. The homogeneity and stability level of Pb, As and Hg in the cream sample were fit for the objective of the comparison. Each participant received two numbered bottles containing about 5g samples in each bottle. The instruction

  18. Report of the key comparison CCQM-K108 determination of arsenic species, total arsenic and cadmium in brown rice flour

    Science.gov (United States)

    Hioki, Akiharu; Narukawa, Tomohiro; Inagaki, Kazumi; Miyashita, Shinichi; Kotzeva, Boriana; Kakoulides, Elias; Sxoina, Vasiliki; Fung, W. H.; Choi, Y. Y.; Yau, H. P.; Tsoi, Y. T.; Lee, C. L.; Kong, M. F.; Shin, Richard; Juan, Wang; Sin Yee, Ng; Uribe, Christian; Marques Rodrigues, Janaína; Caciano de Sena, Rodrigo; Silva Dutra, Emily; Bergamaschi, Luigi; Giordani, Laura; D'Agostino, Giancarlo; Valiente, Liliana; Horvat, Milena; Jacimovic, Radojko; Oduor Okumu, Tom; Kang'Iri, Jacqueline; Owiti Orwa, Tabitha; Chao, Wei; Jingbo, Chao; Taebunpakul, Sutthinun; Yafa, Charun; Kaewkhomdee, Nattikarn; Chailap, Benjamat; Pharat, Yanee; Phukphattanachai, Pranee; Turk, Gregory C.; Long, Stephen; Murphy, K. E.; Davis, Clay; Ellisor, Michael; Merrick, Jeffrey; White, Ian; Saxby, David; Linsky, S. M.; Barzev, A.; Botha, A.

    2015-01-01

    The CCQM-K108 key comparison was organised by the Inorganic Analysis Working Group (IAWG) of CCQM to test the abilities of national metrology institutes (NMIs) or designated institutes (DIs) to measure the mass fractions of arsenic species, total arsenic and cadmium in brown rice flour. The National Metrology Institute of Japan (NMIJ) acted as the coordinating laboratory. The participants used different measurement methods, though most of them used inductively coupled plasma mass spectrometry (ICP-MS) or isotope-dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) for Cd and ICP-MS for total arsenic. Regarding arsenic speciation, all participants used ICP-MS coupled with liquid chromatography (LC). Accounting for relative expanded uncertainty, comparability of measurement results for each of total arsenic and cadmium was successfully demonstrated by the participating NMIs or DIs for the measurement of the measurand at the level of less than 0.5 mg/kg. Regarding arsenic species (inorganic arsenic and dimethylarsinic acid (DMAA)), there was, however, a measurement problem still to be solved and that part of CCQM-K108 will be repeated. It is expected that arsenic, cadmium and other metals at mass fractions greater than approximately 0.1 mg/kg in rice flour can be determined by each participant using the same technique(s) employed for this key comparison to achieve similar uncertainties mentioned in the present report. Furthermore, the results of this key comparison can be utilised along with the IAWG core capability approach. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. CCQM-K108.2014: determination of arsenic species and total arsenic in brown rice flour

    Science.gov (United States)

    Inagaki, K.; Narukawa, T.; Hioki, A.; Miyashita, S.; Long, S. E.; Ellisor, M. B.; Peng, S. L.; Dewi, F.; Shin, R.; Kapp, T.; Wai-hong, F.; Hei-shing, C.; Chao, W.; Kaewkhomdee, N.; Taebunpakul, S.; Thiengmanee, U.; Yafa, C.

    2017-01-01

    The key comparison CCQM-K108.2014 was organised by the Inorganic Analysis Working Group (IAWG) of CCQM to test the abilities of the national metrology institutes (NMIs) or the designated institutes (DIs) to measure the mass fractions of inorganic arsenic (i-As, sum of the amount of arsenite [As(III)] and arsenate [As(V)]), dimethylarsinic acid (DMAA), and total arsenic (total As) in brown rice flour. This was the follow-up comparison for the CCQM-K108 & CCQM-P147 (Cd, As, inorganic arsenic, and DMAA in brown rice flour). For total As, no strong outliers among the reported values were observed, and the distribution of the results was narrow, within 3% around the median. For i-As and DMAA, the distributions of the results were slightly wider than that for total arsenic, but no strong outliers among the reported values of i-As and DMAA were observed. Two potentially bias sources, an extraction efficiency of As species (the ratio of the sum of i-As and DMAA to total As) and the quality of primary standard of DMAA, were discussed. The extraction efficiency was estimated as the ratio of the sum of i-As and DMAA to total As. In the previous comparison (CCQM-K108 & CCQM-P147), the extraction efficiency was one of the largest bias sources for i-As and DMAA. However, in this study, all the extraction efficiencies estimated from the reported values were close to 100 %. Regarding the quality of the primary standard solutions, no significant difference was observed among the primary standard solution used by the participants. These results suggest the two potential bias sources mentioned above would not have been majors in this study, and then the technical issues in the previous comparison had been overcome. Accounting for relative expanded uncertainty, a comparability of measurement was successfully demonstrated by the participating NMIs and DIs for the measurement of total As at the level of less than 0.7 mg/kg, i-As at the level of less than 0.6 mg/kg, and DMAA at the level

  20. Final report on international comparison CCQM-K83: Halocarbons in dry whole air

    Science.gov (United States)

    Rhoderick, George; Guenther, Franklin; Duewer, David; Lee, Jeongsoon; Moon, Dongmin; Lee, Jinbok; Lim, Jeongsik; Seog Kim, Jin

    2014-01-01

    The growing awareness of climate change/global warming and continuing concerns regarding stratospheric ozone depletion will require future measurements and standards for many compounds, in particular halocarbons that are linked to these issues. In order to track and control the emissions of these species globally in the atmosphere, it is necessary to demonstrate measurement equivalence at the highest levels of accuracy for assigned values of standards. This report describes the results of a key comparison for several of the more important halocarbons at atmospheric concentration levels. The comparison includes the chlorofluorocarbons (CFCs) dichlorodifluoromethane (CFC 12), trichlorofluoromethane (CFC 11), and 1,1,2 trichlorotrifluoroethane (CFC 113); the hydrochlorofluorocarbons (HCFCs) chlorodifluoromethane (HCFC 22) and 1-chloro-1,1-difluoroethane (HCFC 142b); and the hydrofluorocarbon (HFC) 1,1,1,2 tetrafluoroethane (HFC 134a), all in a dried whole air sample. The objective of this key comparison is to compare the measurement capabilities of the participants for these halocarbons at trace atmospheric levels. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. KEY COMPARISON: CCQM-K61: Quantitation of a linearised plasmid DNA, based on a matched standard in a matrix of non-target DNA

    Science.gov (United States)

    Woolford, Alison; Holden, Marcia; Salit, Marc; Burns, Malcolm; Ellison, Stephen L. R.

    2009-01-01

    Key comparison CCQM-K61 was performed to demonstrate and document the capability of interested national metrology institutes in the determination of the quantity of specific DNA target in an aqueous solution. The study provides support for the following measurement claim: "Quantitation of a linearised plasmid DNA, based on a matched standard in a matrix of non-target DNA". The comparison was an activity of the Bioanalysis Working Group (BAWG) of the Comité Consultatif pour la Quantité de Matière and was coordinated by NIST (Gaithersburg, USA) and LGC (Teddington, UK). The following laboratories (in alphabetical order) participated in this key comparison. DMSC (Thailand); IRMM (European Union); KRISS (Republic of Korea); LGC (UK); NIM (China); NIST (USA); NMIA (Australia); NMIJ (Japan); VNIIM (Russian Federation) Good agreement was observed between the reported results of all nine of the participants. Uncertainty estimates did not account fully for the dispersion of results even after allowance for possible inhomogeneity in calibration materials. Preliminary studies suggest that the effects of fluorescence threshold setting might contribute to the excess dispersion, and further study of this topic is suggested Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  2. Final report on CCQM-K79: Comparison of value-assigned CRMs and PT materials: Ethanol in aqueous matrix

    Science.gov (United States)

    Hein, Sebastian; Philipp, Rosemarie; Duewer, David L.; Gasca Aragon, Hugo; Lippa, Katrice A.; Toman, Blaza

    2013-01-01

    The 2010 CCQM-K79 'Comparison of value-assigned CRMs and PT materials: Ethanol in aqueous media' is the second key comparison directly testing the chemical measurement services provided to customers by National Metrology Institutes (NMIs) and Designated Institutes (DIs). CCQM-K79 compared the assigned ethanol values of proficiency test (PT) and certified reference materials (CRMs) using measurements made on these materials under repeatability conditions. Nine NMIs submitted 27 CRM or value-assigned PT materials for evaluation. These materials represent many of the higher-order reference materials then available for this commercially and forensically important measurand. The assigned ethanol mass fraction in the materials ranged from 0.1 mg/kg to 334 mg/kg. All materials were stored and prepared according the specifications provided by each NMI. Samples were processed and analyzed under repeatability conditions by one analytical team using a gas chromatography with flame ionization detection (GC-FID) method of demonstrated trueness and precision. Given the number of materials and the time required for each analysis, the majority of the measurements were made in two measurement campaigns ('runs'). Due to a shipping delay from one NMI, an unanticipated third campaign was required. In all three campaigns, replicate analyses (three injections of one preparation separated in time) were made for one randomly selected unit of each of the 27 materials. Nine of the 27 materials were gravimetrically diluted before measurement to provide solutions with ethanol mass fraction in the established linear range of the GC-FID method. The repeatability measurement value for each analyzed solution was estimated as the mean of all replicate values. The within- and between-campaign variance components were estimated using one-way ANOVA. Markov Chain Monte Carlo Bayesian analysis was used to estimate 95% level-of-confidence coverage intervals for the mean values. Uncertainty

  3. Final report on CCQM-K80: Comparison of value-assigned CRMs and PT materials: Creatinine in human serum

    Science.gov (United States)

    Camara, Johanna E.; Duewer, David L.; Gasca Aragon, Hugo; Lippa, Katrice A.; Toman, Blaza

    2013-01-01

    The 2009 CCQM-K80 'Comparison of value-assigned CRMs and PT materials: creatinine in human serum' is the first in a series of key comparisons directly testing the chemical measurement services provided to customers by National Metrology Institutes (NMIs) and Designated Institutes. CCQM-K80 compared the assigned serum creatinine values of certified reference materials (CRMs) using measurements made on these materials under repeatability conditions. Six NMIs submitted 17 CRM materials for evaluation, all intended for sale to customers. These materials represent nearly all of the higher-order CRMs then available for this clinically important measurand. The certified creatinine mass fraction in the materials ranged from 3 mg/kg to 57 mg/kg. All materials were stored and prepared according the specifications provided by each NMI. Samples were processed and analyzed under repeatability conditions by one analyst using isotope dilution liquid chromatography-mass spectrometry. The instrumental repeatability imprecision, expressed as a percent relative standard deviation, was 1.2%. Given the number of materials and the time required for each analysis, the measurements were made in two measurement campaigns ('runs'). In both campaigns, replicate analyses (two injections of one preparation separated in time) were made on each of two or three independently prepared aliquots from one randomly selected unit of each of the 17 materials. The mean value, between-campaign, between-aliquot and between-replicate variance components, standard uncertainty of the mean value, and the number of degrees of freedom associated with the standard uncertainty were estimated using a linear mixed model. Since several of the uncertainties estimated using this traditional frequentist approach were associated with a single degree of freedom, Markov Chain Monte Carlo Bayesian analysis was used to estimate 95% level-of-confidence coverage intervals, U95. Uncertainty-weighted generalized distance

  4. Final report on key comparison COOMET.QM-K36 (Project COOMET 540/UA/11) 'Electrolytic Conductivity 0,5 S/m'

    Science.gov (United States)

    Gavrilkin, V.; Prokopenko, L.; Bakovec, N.; Zolotorevich, E.; Suvorov, V.; Ovchinnikov, Yu; Pilishvili, T.; Buleishvili, M.; Zhasanbaeva, B.; Aytzhatova, G.; Ticona, G.; Vyskocil, L.

    2015-01-01

    The COOMET.QM-K36 key comparison 'Electrolytic conductivity: 0.5 S/m' is a comparison in the field of electrolytic conductivity measurements conducted by COOMET and carried out in 2012. It used a solution of KCl in water and the results are connected to those of the CCQM key comparison CCQM-K36.a through common participation of VNIIFTRI (Russia), SMU (Slovakia) and Ukrmetrteststandart (Ukraine). The purpose of this key comparison was to establish the equivalence of measurements of electrolytic conductivity performed at the National Metrology Institutes of COOMET member states for the value of 0.5 S/m. The results can be used to support the CMCs claims over the range of 0.1 S/m to 1.3 S/m. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. CCQM-K90, formaldehyde in nitrogen, 2 μmol mol-1 Final report

    Science.gov (United States)

    Viallon, Joële; Flores, Edgar; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert Ian; Kim, D.; Kim, Y. D.; Lee, S.; Persijn, S.; Konopelko, L. A.; Kustikov, Y. A.; Malginov, A. V.; Chubchenko, I. K.; Klimov, A. Y.; Efremova, O. V.; Zhou, Z.; Possolo, A.; Shimosaka, T.; Brewer, P.; Macé, T.; Ferracci, Valerio; Brown, Richard J. C.; Aoki, Nobuyuki

    2017-01-01

    The CCQM-K90 comparison is designed to evaluate the level of comparability of national metrology institutes (NMI) or designated institutes (DI) measurement capabilities for formaldehyde in nitrogen at a nominal mole fraction of 2 μmol mol-1. The comparison was organised by the BIPM using a suite of gas mixtures prepared by a producer of specialty calibration gases. The BIPM assigned the formaldehyde mole fraction in the mixtures by comparison with primary mixtures generated dynamically by permeation coupled with continuous weighing in a magnetic suspension balance. The BIPM developed two dynamic sources of formaldehyde in nitrogen that provide two independent values of the formaldehyde mole fraction: the first one based on diffusion of trioxane followed by thermal conversion to formaldehyde, the second one based on permeation of formaldehyde from paraformaldehyde contained in a permeation tube. Two independent analytical methods, based on cavity ring down spectroscopy (CRDS) and Fourier transform infrared spectroscopy (FTIR) were used for the assignment procedure. Each participating institute was provided with one transfer standard and value assigned the formaldehyde mole fraction in the standard based on its own measurement capabilities. The stability of the formaldehyde mole fraction in transfer standards was deduced from repeated measurements performed at the BIPM before and after measurements performed at participating institutes. In addition, 5 control standards were kept at the BIPM for regular measurements during the course of the comparison. Temporal trends that approximately describe the linear decrease of the amount-of-substance fraction of formaldehyde in nitrogen in the transfer standards over time were estimated by two different mathematical treatments, the outcomes of which were proposed to participants. The two treatments also differed in the way measurement uncertainties arising from measurements performed at the BIPM were propagated to the

  6. KEY COMPARISON: Final report of EUROMET Project 696: pH determination of a phthalate buffer

    Science.gov (United States)

    Spitzer, Petra; Charlet, Philippe; Eberhard, Ralf; Karpov, Oleg V.; Philippe, Rachel; Rivier, Cedric; Maximov, Igor; Sudmeier, Uwe

    2005-01-01

    The EUROMET project 696, a trilateral comparison between PTB, Germany, LNE, France and VNIIFTRI, Russia was performed in order to demonstrate and document the capability of the participants to measure the pH of a phthalate buffer by the primary measurement procedure for pH. Good agreement of the reported results was observed. The sample was very similar to the one used in the comparison CCQM-K17. PTB acts as pilot laboratory in CCQM-K17 and in EUROMET 696. This comparison allows one to link the results obtained by LNE to the CCQM-K17 key comparison through the degree of equivalence of PTB. On the other hand, the discrepancy between measured pH values at the VNIIFTRI and PTB for the same type of buffer solution decreased, as compared with a bilateral comparison in 1997. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  7. An international comparability study on quantification of mRNA gene expression ratios: CCQM-P103.1

    Directory of Open Access Journals (Sweden)

    Alison S. Devonshire

    2016-06-01

    Full Text Available Measurement of RNA can be used to study and monitor a range of infectious and non-communicable diseases, with profiling of multiple gene expression mRNA transcripts being increasingly applied to cancer stratification and prognosis. An international comparison study (Consultative Committee for Amount of Substance (CCQM-P103.1 was performed in order to evaluate the comparability of measurements of RNA copy number ratio for multiple gene targets between two samples. Six exogenous synthetic targets comprising of External RNA Control Consortium (ERCC standards were measured alongside transcripts for three endogenous gene targets present in the background of human cell line RNA. The study was carried out under the auspices of the Nucleic Acids (formerly Bioanalysis Working Group of the CCQM. It was coordinated by LGC (United Kingdom with the support of National Institute of Standards and Technology (USA and results were submitted from thirteen National Metrology Institutes and Designated Institutes. The majority of laboratories performed RNA measurements using RT-qPCR, with datasets also being submitted by two laboratories based on reverse transcription digital polymerase chain reaction and one laboratory using a next-generation sequencing method. In RT-qPCR analysis, the RNA copy number ratios between the two samples were quantified using either a standard curve or a relative quantification approach. In general, good agreement was observed between the reported results of ERCC RNA copy number ratio measurements. Measurements of the RNA copy number ratios for endogenous genes between the two samples were also consistent between the majority of laboratories. Some differences in the reported values and confidence intervals (‘measurement uncertainties’ were noted which may be attributable to choice of measurement method or quantification approach. This highlights the need for standardised practices for the calculation of fold change ratios and

  8. Final report on AFRIMETS.QM-K27: Determination of ethanol in aqueous matrix

    Science.gov (United States)

    Archer, Marcellé; Fernandes-Whaley, Maria; Visser, Ria; de Vos, Jayne; Prins, Sara; Rosso, Adriana; Ruiz de Arechavaleta, Mariana; Tahoun, Ibrahim; Kakoulides, Elias; Luvonga, Caleb; Muriira, Geoffrey; Naujalis, Evaldas; Zakaria, Osman Bin; Buzoianu, Mirella; Bebic, Jelena; Achour Mounir, Ben; Thanh, Ngo Huy

    2013-01-01

    From within AFRIMETS, the Regional Metrology Organization (RMO) for Africa, the RMO Key Comparison AFRIMETS.QM-K27 was coordinated by the National Metrology Institute of South Africa (NMISA) in 2011. Ten Metrology Institutes participated, comprising three AFRIMETS, two APMP, four EURAMET and one SIM participant. Participants were required to determine the forensic level concentration of two aqueous ethanol solutions that were gravimetrically prepared by the NMISA. Concentrations were expected to lie in the range of 0.1 mg/g to 5.0 mg/g. The accurate determination of ethanol content in aqueous medium is critical for regulatory forensic and trade purposes. The CCQM Organic Analysis Working Group has carried out several key comparisons (CCQM-K27 series) on the determination of ethanol in wine and aqueous matrices. Developing NMIs now had the opportunity to link to the earlier CCQM-K27 studies through the AFRIMETS.QM-K27 study. Gas chromatography coupled to flame ionisation or mass spectrometric detection was applied by eight of the participants, while three participants (including NMISA) applied titrimetry for the ethanol assay. The assigned reference value of the aqueous ethanol solutions was used to link AFRIMETS.QM-K27 to the CCQM-K27 key comparison reference value. The assigned reference values for AFRIMETS.QM-K27 Level 1 and Level 2 were (0.3249 ± 0.0021) mg/g (k = 2) and (4.6649 ± 0.0152) mg/g (k = 2), respectively. The reference values were determined using the purity-corrected gravimetric preparation values, while the standard uncertainty incorporated the gravimetric preparation and titrimetric homogeneity uncertainties. From previous CCQM-K27 studies, the expected spread (%CV) of higher order measurements of ethanol in aqueous medium is about 0.85% relative. In this study the CV for Level 1 is about 12% (10% with two outliers removed) and for Level 2 about 4%. Three of the ten laboratories submitted results within 1.5% of the gravimetric reference value for

  9. Final report on EURAMET.QM-K12: EURAMET key comparison on the determination of the mass fraction of creatinine in serum

    Science.gov (United States)

    Bell, David; Hopley, Chris; Ellison, Stephen L. R.; O'Connor, Gavin

    2013-01-01

    Creatinine is a well-known marker for the evaluation of kidney function. Its routine measurement is undertaken by many clinical laboratories and comparable results over distance and time are required for effective diagnosis. To address this need many National Measurement Institutes (or designated institutes) provide services in this area via the provision of higher order standards or reference measurements. The organic analysis working group of the consultative committee for amount of substance have conducted two previous key comparisons to assess the equivalence of institutes who provide such services. The purpose of this study was to enable institutes who missed the previous studies to demonstrate their capability for characterizing serum materials containing 1 µg/g to 100 µg/g of creatinine. The study material consisted of two lyophilized serum samples which were used in an external quality control proficiency testing scheme. No target values were available for these materials and all participants reported results within the one month timeframe given for analysis. Five institutes participated in the key study and a single institute submitted results for the parallel pilot study. All participants in the key study used isotope dilution with either gas or liquid chromatography coupled with mass spectrometry. The pilot study laboratory used a novel isotope dilution surface-enhanced Raman spectroscopy method. The comparison reference value for each material was set as the mean of all results submitted by those participating in the key study. The choice of the reference value estimator was constrained as it was deemed more appropriate to treat the data in a similar manner to CCQM-K12 if the relative degrees of equivalence were to be compared. This resulted in reference values of (54.27 ± 0.72) µg/g and (38.01 ± 0.42) µg/g for the two separate materials. The relative degrees of equivalence were calculated and these were compared with the relative degrees of

  10. Final report on CCQM-P151: Halocarbons in dry whole air

    Science.gov (United States)

    Rhoderick, George; Guenther, Franklin; Duewer, David; Lee, Jeongsoon; Seog Kim, Jin; Hall, Bradley; Weiss, Ray; Harth, Christina; Reimann, Stefan; Vollmer, Martin

    2014-01-01

    The growing awareness of climate change/global warming and continuing concerns regarding stratospheric ozone depletion will require future measurements and standards for many compounds, in particular halocarbons that are linked to these issues. In order to track and control the emissions of these species globally in the atmosphere, it is necessary to demonstrate measurement equivalence at the highest levels of accuracy for assigned values of standards. This report describes the results of a pilot study between National Metrology Institutes and atmospheric research laboratories for several of the more important halocarbons at atmospheric concentration levels. The comparison includes the chlorofluorocarbons (CFCs) dichlorodifluoromethane (CFC 12), trichlorofluoromethane (CFC 11), and 1,1,2-trichlorotrifluoroethane (CFC 113); the hydrochlorofluorocarbons (HCFCs) chlorodifluoromethane (HCFC 22) and 1-chloro-1,1-difluoroethane (HCFC 142b); and the hydrofluorocarbon (HFC) 1,1,1,2-tetrafluoroethane (HFC 134a), all in a dried whole air sample. The objective of this key comparison is to compare the measurement capabilities of the participants for these halocarbons at trace atmospheric levels. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM.

  11. k-t SENSE-accelerated Myocardial Perfusion MR Imaging at 3.0 Tesla - comparison with 1.5 Tesla

    Science.gov (United States)

    Plein, Sven; Schwitter, Juerg; Suerder, Daniel; Greenwood, John P.; Boesiger, Peter; Kozerke, Sebastian

    2008-01-01

    Purpose To determine the feasibility and diagnostic accuracy of high spatial resolution myocardial perfusion MR at 3.0 Tesla using k-space and time domain undersampling with sensitivity encoding (k-t SENSE). Materials and Methods The study was reviewed and approved by the local ethic review board. k-t SENSE perfusion MR was performed at 1.5 Tesla and 3.0 Tesla (saturation recovery gradient echo pulse sequence, repetition time/echo time 3.0ms/1.0ms, flip angle 15°, 5x k-t SENSE acceleration, spatial resolution 1.3×1.3×10mm3). Fourteen volunteers were studied at rest and 37 patients during adenosine stress. In volunteers, comparison was also made with standard-resolution (2.5×2.5×10mm3) 2x SENSE perfusion MR at 3.0 Tesla. Image quality, artifact scores, signal-to-noise ratios (SNR) and contrast-enhancement ratios (CER) were derived. In patients, diagnostic accuracy of visual analysis to detect >50% diameter stenosis on quantitative coronary angiography was determined by receiver-operator-characteristics (ROC). Results In volunteers, image quality and artifact scores were similar for 3.0 Tesla and 1.5 Tesla, while SNR was higher (11.6 vs. 5.6) and CER lower (1.1 vs. 1.5, p=0.012) at 3.0 Tesla. Compared with standard-resolution perfusion MR, image quality was higher for k-t SENSE (3.6 vs. 3.1, p=0.04), endocardial dark rim artifacts were reduced (artifact thickness 1.6mm vs. 2.4mm, pTesla and 1.5 Tesla, respectively. Conclusions k-t SENSE accelerated high-resolution perfusion MR at 3.0 Tesla is feasible with similar artifacts and diagnostic accuracy as at 1.5 Tesla. Compared with standard-resolution perfusion MR, image quality is improved and artifacts are reduced. PMID:18936311

  12. Establishing comparability and compatibility in the purity assessment of high purity zinc as demonstrated by the CCQM-P149 intercomparison

    Science.gov (United States)

    Vogl, Jochen; Kipphardt, Heinrich; Richter, Silke; Bremser, Wolfram; del Rocío Arvizu Torres, María; Manzano, Judith Velina Lara; Buzoianu, Mirella; Hill, Sarah; Petrov, Panayot; Goenaga-Infante, Heidi; Sargent, Mike; Fisicaro, Paola; Labarraque, Guillaume; Zhou, Tao; Turk, Gregory C.; Winchester, Michael; Miura, Tsutomu; Methven, Brad; Sturgeon, Ralph; Jährling, Reinhard; Rienitz, Olaf; Mariassy, Michal; Hankova, Zuzana; Sobina, Egor; Ivanovich Krylov, Anatoly; Anatolievich Kustikov, Yuri; Vladimirovich Smirnov, Vadim

    2018-04-01

    For the first time, an international comparison was conducted on the determination of the purity of a high purity element. Participants were free to choose any analytical approach appropriate for their institute’s applications and services. The material tested was a high purity zinc, which had earlier been assessed for homogeneity and previously used in CCQM-K72 for the determination of six defined metallic impurities. Either a direct metal assay of the Zn mass fraction was undertaken by EDTA titrimetry, or an indirect approach was used wherein all impurities, or at least the major ones, were determined and their sum subtracted from ideal purity of 100%, or 1 kg kg-1. Impurity assessment techniques included glow discharge mass spectrometry, inductively coupled plasma mass spectrometry and carrier gas hot extraction/combustion analysis. Up to 91 elemental impurities covering metals, non-metals and semi-metals/metalloids were quantified. Due to the lack of internal experience or experimental capabilities, some participants contracted external laboratories for specific analytical tasks, mainly for the analysis of non-metals. The reported purity, expressed as zinc mass fraction in the high purity zinc material, showed excellent agreement for all participants, with a relative standard deviation of 0.011%. The calculated reference value, w(Zn)  =  0.999 873 kg kg-1, was assigned an asymmetric combined uncertainty of  +0.000 025 kg kg-1 and  -0.000 028 kg kg-1. Comparability amongst participating metrology institutes is thus demonstrated for the purity determination of high purity metals which have no particular difficulties with their decomposition/dissolution process when solution-based analytical methods are used, or which do not have specific difficulties when direct analysis approaches are used. Nevertheless, further development is required in terms of uncertainty assessment, quantification of non-metals and the determination of purity

  13. BIPM comparison BIPM.RI(II)-K1.Zn-65 of activity measurements of the radionuclide 65Zn for the BARC (India) with linked results for the CCRI(II)-K2.Zn-65 comparison

    International Nuclear Information System (INIS)

    Michotte, C.; Ratel, G.; Courte, S.; Joseph, L.

    2015-01-01

    A new participation in the BIPM.RI(II)-K1.Zn-65 comparison has been added to the previous results. A link has been made to the CCRI(II)-K2.Zn-65 comparison held in 2003 through the measurement of all ampoules of the K2 comparison in the International Reference System (SIR) at the BIPM before despatch to the participants. This has produced a revised value for the key comparison reference value (KCRV), calculated using the power-moderated weighted mean. Six NMIs used the K2 comparison to update their degree of equivalence. The degrees of equivalence between each equivalent activity measured in the International Reference System (SIR) and the KCRV have been calculated and the results are given in the form of a table for the remaining two NMIs in the BIPM.RI(II)-K1.Zn-65 comparison and the 17 other participants in the CCRI(II)-K2.Zn-65 comparison. A graphical presentation is also given. (authors)

  14. KEY COMPARISON: CCT-K2.1: NRC/VNIIFTRI bilateral comparison of capsule-type standard platinum resistance thermometers from 13.8 K to 273.16 K

    Science.gov (United States)

    Hill, K. D.; Steele, A. G.; Dedikov, Y. A.; Shkraba, V. T.

    2005-01-01

    The Consultative Committee for Thermometry Key Comparison 2 (CCT-K2) results were published two years ago (2002 Metrologia 39 551-71). NRC served as the pilot laboratory for CCT-K2 and remains able to provide a scale and measurement system suitable for performing bilateral comparisons linked to the original key comparison results. In March 2003, measurements of two VNIIFTRI 100 Ω capsule-style platinum resistance thermometers (CSPRTs), S/N 356 and 476, were undertaken to relate their local calibration to the results from the CCT-K2 exercise. The NRC Leeds and Northrup (L&N) CSPRT S/N 1872174 provides the link to the CCT-K2 results. The three CSPRTs were compared at the eight defining cryogenic temperatures of the International Temperature Scale of 1990 (ITS-90) in the range from 13.8033 K to 273.16 K. The reader is referred to the full text of the CCT-K2 report for a detailed explanation of the methodology employed for the comparison. Only the details unique to the measurements reported here will be addressed in this article. The NRC/VNIIFTRI bilateral comparison of capsule-style platinum resistance thermometers over the range 13.8 K to 273.16 K has revealed calibrations at VNIIFTRI to be in agreement with the KCRV of CCT-K2 within the expanded uncertainty for all temperatures of the comparison with the exception of the triple point of hydrogen at 13.8033 K. One of the two CSPRTs supplied by VNIIFTRI was found to be discrepant as revealed by differences at the triple point of water and at the lowest temperatures of the comparison, and was therefore excluded from further analysis. The linkage to the CCT-K2 data supports the evaluation of the VNIIFTRI CMCs in Appendix C of the KCDB. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions

  15. Subsequent bilateral comparison to CCT-K3, CIPM key comparison CCT-K3.1: Comparison of standard platinum resistance thermometers at the triple point of water (T = 273.16 K) and at the melting point of gallium (T = 302.9146 K)

    Science.gov (United States)

    Picard, S.; Nonis, M.; Solve, S.; Allisy-Roberts, P. J.; Renaot, E.; Martin, C.

    2011-01-01

    A comparison of standard platinum resistance thermometers (SPRTs) has been carried out between the BIPM and the Laboratoire commun de métrologie LNE-CNAM using the melting point of gallium and the triple point of water. The temperature difference at Ga between the BIPM and the LNE-CNAM was determined as 108 µK with an associated combined standard uncertainty of 223 µK. This outcome indicates a present temperature difference of the BIPM of -65 µK with respect to an Average Reference Value from an earlier comparison, with an associated uncertainty of uc = 262 µK. It should be noted that the present BIPM scale is not independent, but traceable to cells used in KC7. The comparison results validate the re-establishment of thermometer calibrations at the BIPM for internal use. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  16. Final report on RMO Vickers key comparison COOMET M.H-K1

    Science.gov (United States)

    Aslanyan, E.; Menelao, F.; Herrmann, K.; Aslanyan, A.; Pivovarov, V.; Galat, E.; Dovzhenko, Y.; Zhamanbalin, M.

    2013-01-01

    This report describes a COOMET key comparison on Vickers hardness scales involving five National Metrology Institutes: PTB (Germany), BelGIM (Belarus), NSC IM (Ukraine), KazInMetr (Kazakhstan) and VNIIFTRI (Russia). The pilot laboratory was VNIIFTRI, and PTB acted as the linking institute to key comparisons CCM.H-K1.b and CCM.H-K1.c conducted for the Vickers hardness scales HV1 and HV30, respectively. The comparison was also conducted for the HV5 Vickers hardness scale, since this scale is most frequently used in practice in Russia and CIS countries that work according to GOST standards. In the key comparison, two sets of hardness reference blocks for the Vickers hardness scales HV1, HV5 and HV30 consisting each of three hardness reference blocks with hardness levels of 450 HV and 750 HV were used. The measurement results and uncertainty assessments for HV1 and HV30 hardness scales, as announced by BelGIM, NSC IM, KazInMetr and VNIIFTRI, are in good agreement with the key comparison reference values of CCM.H-K1.b and CCM.H-K1.c. The comparison results for the HV5 hardness scale are viewed as additional information, since up to today no CCM key comparisons on this scale have yet been carried out. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. CCT-K2.1: NRC/VNIIFTRI bilateral comparison of capsule-type standard platinum resistance thermometers from 13.8 K to 273.16 K

    Energy Technology Data Exchange (ETDEWEB)

    Hill, K.D.; Steele, A.G. [National Research Council of Canada, Institute for National Measurement Standards, Ottawa, ON (Canada); Dedikov, Y.A.; Shkraba, V.T. [Institute for Physical-Technical and Radiotechnical Measurements (VNIIFTRI), Moscow (Russian Federation)

    2005-04-01

    The Consultative Committee for Thermometry Key Comparison 2 (CCT-K2) results were published two years ago (2002 Metrologia 39 551-71). NRC served as the pilot laboratory for CCT-K2 and remains able to provide a scale and measurement system suitable for performing bilateral comparisons linked to the original key comparison results. In March 2003, measurements of two VNIIFTRI 100 {omega} capsule-style platinum resistance thermometers (CSPRTs), S/N 356 and 476, were undertaken to relate their local calibration to the results from the CCT-K2 exercise. The NRC Leeds and Northrup (L and N) CSPRT S/N 1872174 provides the link to the CCT-K2 results. The three CSPRTs were compared at the eight defining cryogenic temperatures of the International Temperature Scale of 1990 (ITS-90) in the range from 13.8033 K to 273.16 K. The reader is referred to the full text of the CCT-K2 report for a detailed explanation of the methodology employed for the comparison. Only the details unique to the measurements reported here will be addressed in this article. The NRC/VNIIFTRI bilateral comparison of capsule-style platinum resistance thermometers over the range 13.8 K to 273.16 K has revealed calibrations at VNIIFTRI to be in agreement with the KCRV of CCT-K2 within the expanded uncertainty for all temperatures of the comparison with the exception of the triple point of hydrogen at 13.8033 K. One of the two CSPRTs supplied by VNIIFTRI was found to be discrepant as revealed by differences at the triple point of water and at the lowest temperatures of the comparison, and was therefore excluded from further analysis. The linkage to the CCT-K2 data supports the evaluation of the VNIIFTRI CMCs in Appendix C of the KCDB. (authors)

  18. International comparison of AC-DC current transfer standards

    Science.gov (United States)

    Heine, G.; Garcocz, M.; Waldmann, W.

    2017-01-01

    The measurements of the international comparison of ac-dc current transfer standards identified as EURAMET.EM-K12 started in June 2012 and were completed in December 2014. Twenty NMIs in the EURAMET region and one NMI in the AFRIMET region took part: BEV (Austria), CMI (Czech Republic), PTB (Germany), METAS (Switzerland), JV (Norway), UME (Turkey), GUM (Poland), IPQ (Portugal), CEM (Spain), INRIM (Italy), SP (Sweden), DANIAmet-MI-Trescal (Denmark), BIM (Bulgaria), MKEH (Hungary), SIQ (Slovenia), LNE (France), NSAI NML (Ireland), VSL (The Netherlands), NPL (United Kingdom), Metrosert (Estonia), NIS (Egypt). The comparison was proposed to link the National Metrology Institutes organised in EURAMET to the key comparison CCEM-K12. The ac-dc current transfer difference of each travelling standard had been measured at its nominal current 10 mA and 5 A at the following frequencies: 10 Hz, 55 Hz, 1 kHz, 10 kHz, 20 kHz, 50 kHz, 100 kHz. The test points were selected to link the results with the equivalent CCEM Key Comparison (CCEM-K12), through five NMIs participating in both EURAMET and CCEM key comparisons (PTB, JV, NPL, SP and BEV). The report shows the degree of equivalence in the EURAMET region and also the degree of equivalence with the corresponding CCEM reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Comparison of measurement capability with 100 μmol/mol of carbon monoxide in nitrogen

    Science.gov (United States)

    Lee, Jeongsoon; Lee, JinBok; Lim, Jeongsik; Tarhan, Tanıl; Liu, Hsin-Wang; Aggarwal, Shankar G.

    2018-01-01

    Carbon monoxide (CO) in nitrogen was one of the first types of gas mixtures used in an international key comparison. The comparison dates back to 1998 (CCQMK1a) [1]. Since then, many National Metrology Institutes (NMIs) have developed calibration and measurement capabilities (CMCs) for these mixtures. Recently, NMIs in the APMP region have actively participated in international comparisons to provide domestic services. At the 2013 APMP meeting, several NMIs requested a CO comparison to establish CO/N2 certification for industrial applications, which was to be coordinated by KRISS. Consequently, this comparison provides an opportunity for APMP regional NMIs to develop CO/N2 CMC claims. The goal of this supplementary comparison is to support CMC claim for carbon monoxide in the N2 range of 50–2000 μmol/mol. An extended range may be supported as described in the GAWG strategy for comparisons and CMC claims. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Bilateral Comparison Between NIM and NMC Over the Temperature Range from 83.8058 K to 692.677 K

    Science.gov (United States)

    Sun, Jianping; Ye, Shaochun; Kho, Haoyuan; Zhang, Jintao; Wang, Li

    2015-08-01

    A bilateral comparison of local realization of the International Temperature Scale of 1990 between the National Institute of Metrology (NIM) and National Metrology Centre (NMC) was carried out over the temperature range from 83.8058 K to 692.677 K. It involved six fixed points including the argon triple point, the mercury triple point, the triple point of water, the melting point of gallium, the freezing point of tin, and the freezing point of zinc. In 2009, NMC asked NIM to participate in a bilateral comparison to link the NMC results to the Consultative Committee for Thermometry Key Comparison 3 (CCT-K3) and facilitate the NMC's calibration and measurement capabilities submission. This comparison was agreed by NIM and Asia Pacific Metrology Programme in 2009, and registered in the Key Comparison Database in 2010 as CCT-K3.2. NMC supplied two fused silica sheath standard platinum resistance thermometers (SPRTs) as traveling standards. One of them was used at the Ga, Sn, and Zn fixed points, while the other one was used at the Ar and Hg fixed points. NMC measured them before and after NIM measured them. During the comparison, a criterion for the SPRT was set as the stability at the triple point of water to be less than 0.3 mK. The results for both laboratories are summarized. A proposal for linking the NMC's comparison results to CCT-K3 is presented. The difference between NMC and NIM and the difference between NMC and the CCT-K3 average reference value using NIM as a link are reported with expanded uncertainties at each measured fixed point.

  1. KEY COMPARISON: Final report on APMP.M.P-K6.1 pneumatic key comparison from 20 kPa to 105 kPa in gauge mode

    Science.gov (United States)

    Hung, Chen-Chuan; Jian, Wu; Changpan, Tawat

    2009-01-01

    This report describes the key comparison APMP.M.P-K6.1 among the three national metrology institutes, Center for Measurement Standards-ITRI (CMS-ITRI, Taiwan), SPRING Singapore and National Institute of Metrology (NIMT), in the pressure range from 20 kPa to 105 kPa in gas media and gauge mode executed during the period April 2003 to April 2004. This comparison was conducted by CMS-ITRI and was based on the calibration procedure of APMP pneumatic pressure comparison APMP.M.P-K6. We intended to link to the CCM.P-K6 key comparison through the APMP.M.P-K6 key comparison by using the proposed linkage method in the APMP.M.P-K6 key comparison to determine a linking factor that can transform the quantities measured in the APMP.M.P-K6.1 key comparison. All three participating institutes used pneumatic piston gauges as their pressure standards. The Ruska 2465 gas-operated piston-cylinder assembly TL-1409 used as transfer standard offered by CMS-ITRI was calibrated three times by the pilot institute during the comparison period and showed that it was very stable after evaluation. The comparison was conducted on the basis of cross-float experiments to determine the effective area of transfer standards from the national standards of three institutes. The comparison results (as shown in Table 6) were equivalent to the CCM.P-K6 comparison and the relative bilateral degrees of equivalence between two laboratories were smaller than 39.7 × 10-6 from 20 kPa to 105 kPa. These results showed all participating institutes measuring the same quantity in the whole pressure range lay within their expanded uncertainty with confidence level 95%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  2. CCM key comparison CCM.D-K4 'Hydrometer'

    Science.gov (United States)

    Lorefice, S.; Becerra, L. O.; Lenard, E.; Lee, Y. J.; Lee, W. G.; Madec, T.; Meury, P. A.; Caceres, J.; Santos, C.; Vamossy, C.; Man, J.; Fen, K.; Toda, K.; Wright, J.; Bettin, H.; Toth, H.

    2016-01-01

    This report presents the comparison philosophy, methodology, analysis and the results of the designed CCM.D-K4 key comparison that covered the calibration of high resolution hydrometers for liquid and alcoholometers in the density range 600 kg/m3 to 2000 kg/m3 at the temperature of 20°C. The main purpose of this comparison was not only to evaluate the degree of equivalence in the calibration of high accuracy hydrometers between NMI participants, but also to link, were it is possible, the results of previous comparisons to Key Comparison Reference Values (KCRVs) of CCM.D-K4. Eleven NMI laboratories took part in the CCM.D-K4 divided in two groups (petals). With the CCM.D-K4 purpose, two similar sets consisting of three hydrometers for liquid density determinations and an alcoholometer were circulated to the NMI participants as a travelling standard in the time interval from January 2011 to April 2012. Twelve Key Comparison Reference Values (KCRVs) for each petal have been obtained at the density values related to the tested density marks of the transfer standards by the results of participants. The KCRVs and corresponding uncertainties were calculated by the weighted mean in the case of consistent results, otherwise the median was used. The degree of equivalence (DoE) with respect to the corresponding KCRV was determined for each participant and, in this particular comparison, the Weighted Least Squares (WLS) method was used to link the individual DoE of each participant by a continuous function. Significant drift of the transfer standards was not detected. This report also gives instructions on calculating pair-wise degrees of equivalence, with the addition of any information on correlations that may be necessary to estimate more accurately as well as the procedure for linking international comparisons to the CCM.D-K4. Finally an example of linkage to the CCM.D-K4 is given by dealing with the results of the bilateral comparison between INRiM and NMIA, which was

  3. BIPM comparison BIPM.RI(II)-K1.Eu-152 of activity measurements of the radionuclide 152Eu for the VNIIM (Russia), the LNE-LNHB (France) and the CNEA (Argentina), with linked results for the COOMET.RI(II)-K2.Eu-152 comparison

    International Nuclear Information System (INIS)

    Michotte, C.; Ratel, G.; Courte, S.; Kharitonov, I.A.; Zanevsky, A.V.; Terechtchenko, E.E.; Moune, M.; Aubineau-Laniece, I.; Bobin, C.; Arenillas, P.; Balpardo, C.

    2014-01-01

    Three new participants in the BIPM.RI(II)-K1.Eu-152 comparison have been added to the previous results and this has produced a revised value for the key comparison reference value (KCRV), calculated using the power-moderated weighted mean. A link has been made to the COOMET.RI(II)-K2.Eu-152 comparison held in 2010 through the VNIIM who participated in both comparisons. Three National Metrology Institutes (NMIs) used the K1 or K2 comparisons to update their degree of equivalence. The degrees of equivalence between each equivalent activity measured in the International Reference System (SIR) and the KCRV have been calculated and the results are given in the form of a table for four NMIs in the BIPM.RI(II)-K1.Eu-152 comparison, three participants in the COOMET.RI(II)-K2.Eu-152 comparison and the 18 other participants in the previous CCRI(II)-K2.Eu-152 comparison. A graphical presentation is also given. (authors)

  4. Final report on COOMET Vickers PTB/VNIIFTRI key comparison (COOMET.M.H-K1.b and COOMET.M.H-K1.c)

    Science.gov (United States)

    Aslanyan, E.; Herrmann, K.

    2013-01-01

    This report describes a COOMET key comparison on Vickers hardness scales of two National Metrology Institutes—PTB and VNIIFTRI. The pilot laboratory was PTB, which was the linking institute with the key comparison reference values of CCM.H-K1. In the key comparison two sets of hardness reference blocks for the Vickers hardness scales HV1 and HV30, each consisting of three hardness reference blocks with the hardness levels 240 HV, 540 HV and 840 HV, are used. The same hardness reference blocks were used previously in the key comparison CCM.H-K1. The measurement results and uncertainty assessments, announced by VNIIFTRI, are in good agreement with the key comparison reference values of CCM.H-K1. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. 30 August 2011 - Médecins sans frontières International President U. K Karunakara signing the guest book with Head of International Relations F. Pauss and Adviser for Life Sciences M. Dosanjh; visiting CMS underground experimental area with Collaboration Spokesperson G. Tonelli.

    CERN Multimedia

    Maximilien Brice

    2011-01-01

    30 August 2011 - Médecins sans frontières International President U. K Karunakara signing the guest book with Head of International Relations F. Pauss and Adviser for Life Sciences M. Dosanjh; visiting CMS underground experimental area with Collaboration Spokesperson G. Tonelli.

  6. Peningkatan Laju Disolusi Dispersi Padat Amorf Genistein dengan PVP K-30

    Directory of Open Access Journals (Sweden)

    Erizal Zaini

    2017-12-01

    Full Text Available Amorphous solid dispersions of a poorly water-soluble drug genistein in PVP K-30 were prepared by solvent co-evaporation technique using organic solvent methanol. Solid dispersions system was prepared with several variations of drug to polymer 2:1, 1:1 dan 1:2 w/w. Solid state properties of solid dispersion system were evaluated by powder X-ray diffraction, Fourier transform infrared spectroscopy, and differential scanning calorimetry, and microscopic SEM. Dissolution rate profile were conducted in distilled water medium by using dissolution tester apparatus type II USP. Base on X-ray diffractometry analysis, differential scanning calorimetry and microscopic SEM, crystalline phase of genistein decreased in crystallinity index and formation of amophous state. Dissolution rate profile showed that genistein in amorphous solid dispersion had a faster dissolution rate in comparison to intact genistein. This study proved that preparation of solid dispersion of genistein in PVP K-30 is an effective approach to improve dissolution rate of genistein.

  7. Design of a 30 m long 1 kA 10 kV YBCO cable

    Energy Technology Data Exchange (ETDEWEB)

    Rostila, L [Institute of Electromagnetics, Tampere University of Technology, PO Box 692, FIN-33101 Tampere (Finland); Lehtonen, J [Institute of Electromagnetics, Tampere University of Technology, PO Box 692, FIN-33101 Tampere (Finland); Masti, M [Institute of Electromagnetics, Tampere University of Technology, PO Box 692, FIN-33101 Tampere (Finland); Lallouet, N [Nexas France, rue Mozart 4-10, 92587 Clichy (France); Saugrain, J-M [Nexas France, rue Mozart 4-10, 92587 Clichy (France); Allais, A [Nexans Deutschland Industries GmbH and Co. KG, Kabelkamp 20, D-30179 Hannover (Germany); Schippl, K [Nexans Deutschland Industries GmbH and Co. KG, Kabelkamp 20, D-30179 Hannover (Germany); Schmidt, F [Nexans Deutschland Industries GmbH and Co. KG, Kabelkamp 20, D-30179 Hannover (Germany); Balog, G [Nexans Norway, PO Box 6450, Etterstad, N-0605, Oslo, Norway (Norway); Marot, G [Air Liquide DTA, 2 rue de Clemenciere BP15, 38360 Sassenage (France); Ravex, A [Air Liquide DTA, 2 rue de Clemenciere BP15, 38360 Sassenage (France); Usoskin, A [European High Temperature Superconductors Gmbh and Co. KG, Windausweg 2, 37037 Goettingen (Germany); Goemoery, F [Institute of Electrical Engineering, Slovak Academy of Sciences, Dubravska cesta 9, 84104 Bratislava (Slovakia); Klincok, B [Institute of Electrical Engineering, Slovak Academy of Sciences, Dubravska cesta 9, 84104 Bratislava (Slovakia); Souc, J [Institute of Electrical Engineering, Slovak Academy of Sciences, Dubravska cesta 9, 84104 Bratislava (Slovakia); Freyhardt, H C [Institute of Materialphysic, University of Goettingen, Friedrich-Hund-Platz 1, D-37077 Goettingen (Germany)

    2006-04-15

    In this paper a 30 m long one-phase coaxial YBCO cable with 1 kA transport current and 10 kV operating voltage was designed for the Super3C project to check the feasibility of YBCO tapes for low-loss cables. The final design incorporates cryogenic, mechanical and electromagnetic aspects. The electromagnetic losses during normal operation must be minimized. The cryogenic design must also take into account the generation of heat during short circuit conditions. Mechanical restrictions set the minimum gaps between the coated conductor tapes and the minimum lay angles in order to make the cabling feasible and to enable handling of the cable. The design of the electric insulation should be according to the international standard as far as applicable. The final design has to take into account all of the above restrictions.

  8. Design of a 30 m long 1 kA 10 kV YBCO cable

    International Nuclear Information System (INIS)

    Rostila, L; Lehtonen, J; Masti, M; Lallouet, N; Saugrain, J-M; Allais, A; Schippl, K; Schmidt, F; Balog, G; Marot, G; Ravex, A; Usoskin, A; Goemoery, F; Klincok, B; Souc, J; Freyhardt, H C

    2006-01-01

    In this paper a 30 m long one-phase coaxial YBCO cable with 1 kA transport current and 10 kV operating voltage was designed for the Super3C project to check the feasibility of YBCO tapes for low-loss cables. The final design incorporates cryogenic, mechanical and electromagnetic aspects. The electromagnetic losses during normal operation must be minimized. The cryogenic design must also take into account the generation of heat during short circuit conditions. Mechanical restrictions set the minimum gaps between the coated conductor tapes and the minimum lay angles in order to make the cabling feasible and to enable handling of the cable. The design of the electric insulation should be according to the international standard as far as applicable. The final design has to take into account all of the above restrictions

  9. Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) : Part 2: cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)

    CERN Document Server

    International Electrotechnical Commission. Geneva

    2005-01-01

    Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) : Part 2: cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)

  10. Precision and Accuracy of k0-NAA Method for Analysis of Multi Elements in Reference Samples

    International Nuclear Information System (INIS)

    Sri-Wardani

    2004-01-01

    Accuracy and precision of k 0 -NAA method could determine in the analysis of multi elements contained in reference samples. The analyzed results of multi elements in SRM 1633b sample were obtained with optimum results in bias of 20% but it is in a good accuracy and precision. The analyzed results of As, Cd and Zn in CCQM-P29 rice flour sample were obtained with very good result in bias of 0.5 - 5.6%. (author)

  11. Texture studies of hot-pressed K2Pb4Nb10O30 ceramics

    International Nuclear Information System (INIS)

    Filip'ev, V.S.; Zav'yalov, V.P.; Bunina, O.A.; Gavrilyachenko, S.V.; Fesenko, E.G.

    1984-01-01

    An X-ray diffraction analysis was used to investigate the texture in sampl es of K 2 Pb 4 Nb 10 O 30 ferroelectric produced by powder hot pressing and sintering at 1370-1500 k. A spontaneous formation of the secondary texture during ferroelectric phase transformation was revealed. An important role of internal stresses in the secondary texture formation was supported. The ceramic s with a high-grade texture is noted to be characterized by a high anisotropy of dielectric and piezoelectric properties, its parameters approaching to those of a monocrystal

  12. Application of k0-based internal monostandard NAA for large sample analysis of clay pottery. As a part of inter comparison exercise

    International Nuclear Information System (INIS)

    Acharya, R.; Dasari, K.B.; Pujari, P.K.; Swain, K.K.; Shinde, A.D.; Reddy, A.V.R.

    2014-01-01

    As a part of inter comparison exercise of an IAEA Coordinated Research Project on large sample neutron activation analysis, a large size and non standard geometry size pottery replica (obtained from Peru) was analyzed by k 0 -based internal monostandard neutron activation analysis (IM-NAA). Two large size sub samples (0.40 and 0.25 kg) were irradiated at graphite reflector position of AHWR Critical Facility in BARC, Trombay, Mumbai, India. Small samples (100-200 mg) were also analyzed by IM-NAA for comparison purpose. Radioactive assay was carried out using a 40 % relative efficiency HPGe detector. To examine homogeneity of the sample, counting was also carried out using X-Z rotary scanning unit. In situ relative detection efficiency was evaluated using gamma rays of the activation products in the irradiated sample in the energy range of 122-2,754 keV. Elemental concentration ratios with respect to Na of small size (100 mg mass) as well as large size (15 and 400 g) samples were used to check the homogeneity of the samples. Concentration ratios of 18 elements such as K, Sc, Cr, Mn, Fe, Co, Zn, As, Rb, Cs, La, Ce, Sm, Eu, Yb, Lu, Hf and Th with respect to Na (internal mono standard) were calculated using IM-NAA. Absolute concentrations were arrived at for both large and small samples using Na concentration, obtained from relative method of NAA. The percentage combined uncertainties at ±1 s confidence limit on the determined values were in the range of 3-9 %. Two IAEA reference materials SL-1 and SL-3 were analyzed by IM-NAA to evaluate accuracy of the method. (author)

  13. Graphical comparison of calculated internal conversion coefficients

    International Nuclear Information System (INIS)

    Ewbank, W.B.

    1980-11-01

    Calculated values of the coefficients of internal conversion of gamma rays in the K shell and L 1 , L 2 , L 3 subshells from published tabulations by Band and Trzhaskovskaya and by Roesel et al. at Data Nucl. Data Tables, 21, 92-514(1978) are compared with values obtained by computer interpolation among tabulated values of Hager and Seltzer Nucl. Data, A4, 1-235(1968). In some cases, agreement among the three calculations is remarkably good, and differences are generally less than 5%. In a few cases, there are differences as large as 20 to 50%, corresponding to the threshold effect described by Roesel et al. The Z-dependent resonance minimum described by Roesel et al. is also observed in the comparison of E1-E4 conversion in the L 1 subshell. In several cases (notably M1-M4 conversion in the K shell and L 1 subshell), the Band and Roesel calculations show dramatically different dependence on gamma energy and atomic number. For Z = 100, the Band calculation for E4 conversion in the L 3 subshell shows irregular behavior at energies below the K-shell binding energy. A few high-quality measurements of internal conversion coefficients (+-5%) would help greatly to establish a basis for choice among the theoretical calculations. 32 figures

  14. COOMET.RI(I)-K1 comparison of national measurement standards of air kerma for 60Co γ radiation

    International Nuclear Information System (INIS)

    Buermann, L.; Oborin, A.V.; Dobrovosky, J.; Milevsky, V.S.; Walwyn Salas, G.; Lapenas, A.

    2009-01-01

    Results are presented of the COOMET key comparison of the national measurement standards of air kerma for 60 Co γ radiation. Participants of the comparison were PTB (Germany, pilot institute), VNIIM (Russia), SMU (Slovakia), BelGIM (Belarus), CPHR (Cuba) and RMTC (Latvia). PTB, VNIIM and SMU had previously taken part in a key comparison with the Bureau International de Poids et Mesures (BIPM) and operated as link laboratories in order to evaluate the degree of equivalence of the participants' results with the key comparison reference value. These data form the basis of the results entered into the BIPM key comparison database for comparison COOMET.RI(I)-K1. (authors)

  15. U.K. policy responses to international influences - nuclear power

    International Nuclear Information System (INIS)

    Jones, P.M.S.

    1978-01-01

    An account is given of U.K. participation in international discussions directed towards the safe development and application of nuclear power. Particular attention is given to the International Fuel Cycle Evaluation (INFCE), which is stated to be looking at the whole question of proliferation and the merits and disadvantages of a range of alternative fuel cycles and nuclear power strategies. A summary is also given of U.K. participation in work on radiological protection (through the I.C.R.P.) and radioactive waste disposal. International cooperation in research and development is mentioned. Public involvement in policy making is also discussed briefly. (U.K.)

  16. Supplement to CCM.D-K4 'Hydrometer' report: linkage of EURAMET.M.D-K4 comparison, SIM.M.D-K4 comparison and the supplementary SIM.M.D-S2 to CCM.D-K4 'Hydrometer'

    Science.gov (United States)

    Lorefice, S.; Becerra, L. O.

    2017-01-01

    Evaluation of different types of comparisons to a common set of reference values of a CIPM key comparison is essential to satisfy the concept of the CIPM Mutual Recognition Arrangement (CIPM MRA), where the DoEs of any participant who took part in comparisons should be within the Calibration and Measurement Capability (CMC) section of the CIPM MRA Key Comparison Data Base. The subject of this supplementary report is therefore to present the equivalence of each National Metrological Institute (NMI) participant in the CCM.D-K4 'Hydrometer' key comparison, which was performed in the density range 600 kg/m3 to 2000 kg/m3 at the temperature of 20 °C, and the linkage of the European and Inter-American NMI results performed in the RMO.M.D-K4 comparisons as well as those of the supplementary SIM.M.D-S2 to the common set of KCRVs of the CCM.D-K4 'Hydrometer'. The linking procedure has been obtained by numerical simulation, based on the Monte Carlo method, in which the differences in the results of the different comparison between the intended laboratory and one or more linking laboratory/ies, which took part in both comparisons, are correlated with a continuous function describing the DoEs of the linking laboratory/ies with respect to the common set of KCRVs of the CCM.D-K4. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Quality assurance of in-situ-gammaspectrometry. International comparison measurement at the K-RISK-phantom 2015; Qualitaetssicherung der In-situ-Gammaspektrometrie. Internationale Vergleichsmessung an der K-RISK-Phantomwand 2015

    Energy Technology Data Exchange (ETDEWEB)

    Haas, G.; Schupfner, R. [Regensburg Univ. (Germany). ZRN-URA-Lab.; Buss, K. [Bayerisches Landesamt fuer Umwelt, Kulmbach (Germany)

    2016-07-01

    During the last years the collimated in-situ-gammaspectrometry established itself as a powerful mean for free- release of buildings, parts of buildings, walls and ground area. To accomplish a suitable possibility for quality assurance of in-situ-gammaspectrometry, the K-RISK-phantom wall was developed and built at the University of Regensburg on the authority of the state office for environmental protection, Kulmbach. The K-RISK-phantom is a large surface calibration wall made of concrete which allows simulating different realistic three-dimensional wall contaminations. Contrary to many other calibration phantoms the K-RISK phantom permits completely reversible three-dimensional activity distributions. The comparison measurement is a useful tool for quality assurance and allows the participants to review their measurements relating to measurement, calibration or analysis. 19 institutions (industry, surveyor, authorities) from Germany, Austria and Switzerland participated at the comparison measurement.

  18. Bilateral comparison of 10 kΩ standards (ongoing BIPM key comparison BIPM.EM-K13.b) between the NSAI-NML (Ireland) and the BIPM

    Science.gov (United States)

    Goebel, R.; Power, O.; Fletcher, N.; Stock, M.

    2012-01-01

    This report describes the results obtained from a NML(Ireland)-BIPM bilateral comparison of 10 kΩ resistance standards in 2010. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.b. Two BIPM 10 kΩ travelling standards of SR104 type were calibrated first at the BIPM, then at the NMLI and again at the BIPM after their return. The stability of the transfer standards was such that the uncertainty associated with the transfer was significantly smaller than the uncertainty arising from the calibrations. The NMLI and the BIPM calibrations were found to be in agreement, with a mean difference smaller than the standard uncertainty of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  19. Ouabain-induced internalization and lysosomal degradation of the Na+/K+-ATPase.

    Science.gov (United States)

    Cherniavsky-Lev, Marina; Golani, Ofra; Karlish, Steven J D; Garty, Haim

    2014-01-10

    Internalization of the Na(+)/K(+)-ATPase (the Na(+) pump) has been studied in the human lung carcinoma cell line H1299 that expresses YFP-tagged α1 from its normal genomic localization. Both real-time imaging and surface biotinylation have demonstrated internalization of α1 induced by ≥100 nm ouabain which occurs in a time scale of hours. Unlike previous studies in other systems, the ouabain-induced internalization was insensitive to Src or PI3K inhibitors. Accumulation of α1 in the cells could be augmented by inhibition of lysosomal degradation but not by proteosomal inhibitors. In agreement, the internalized α1 could be colocalized with the lysosomal marker LAMP1 but not with Golgi or nuclear markers. In principle, internalization could be triggered by a conformational change of the ouabain-bound Na(+)/K(+)-ATPase molecule or more generally by the disruption of cation homeostasis (Na(+), K(+), Ca(2+)) due to the partial inhibition of active Na(+) and K(+) transport. Overexpression of ouabain-insensitive rat α1 failed to inhibit internalization of human α1 expressed in the same cells. In addition, incubating cells in a K(+)-free medium did not induce internalization of the pump or affect the response to ouabain. Thus, internalization is not the result of changes in the cellular cation balance but is likely to be triggered by a conformational change of the protein itself. In physiological conditions, internalization may serve to eliminate pumps that have been blocked by endogenous ouabain or other cardiac glycosides. This mechanism may be required due to the very slow dissociation of the ouabain·Na(+)/K(+)-ATPase complex.

  20. 30 CFR 206.155 - Accounting for comparison.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Accounting for comparison. 206.155 Section 206... MANAGEMENT PRODUCT VALUATION Federal Gas § 206.155 Accounting for comparison. (a) Except as provided in... the gas the residue gas is not sold pursuant to an arm's-length contract, the value, for royalty...

  1. KEY COMPARISON: CCEM.RF-K9: International comparison of thermal noise standards between 12.4 GHz and 18 GHz (GT-RF/99-1)

    Science.gov (United States)

    Allal, Djamel; Achkar, Joseph

    2006-01-01

    An international comparison of thermal noise-power measurements has been carried out among five national metrology institutes between 12.4 GHz and 18 GHz. Four transfer standards were measured. The following national institutes participated: BNM-LCIE (France), NPL (United Kingdom), PTB (Germany), NIST (United States of America) and VNIIFTRI (Russia). The Bureau National de Métrologie-Laboratoire Central des Industries Electriques (France) acted as the pilot laboratory for the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  2. International key comparison of neutron fluence measurements in mono-energetic neutron fields: C.C.R.I.(3)-K10

    Energy Technology Data Exchange (ETDEWEB)

    Chen, J.; Wang, Z.; Rong, C. [China Institute of Atomic Energy (CIAE), Beijing, People' s Republic of China (China); Lovestam, G.; Plompen, A.; Puglisi, N. [EC-JRC-Institute for Reference Materials and Measurements (IRMM), Geel (Belgium); Gilliam, D.M.; Eisenhauer, C.M.; Nico, J.S.; Dewey, M.S. [National Institute of Standards and Technology (NIST), Gaithersburg (United States); Kudo, K.; Uritani, A.; Harano, H.; Takeda, N. [National Metrology Institute of Japan (NMIJ), Tsukuba (Japan); Thomas, D.J.; Roberts, N.J.; Bennett, A.; Kolkowski, P. [National Physical Laboratory (NPL), Teddington (United Kingdom); Moisseev, N.N.; Kharitonov, I.A. [Mendeleyev Institute for Metrology (VNIIM), St Petersburg (Russian Federation); Guldbakke, S.; Klein, H.; Nolte, R.; Schlegel, D. [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany)

    2007-12-15

    C.C.R.I. Section III (neutron measurements) conducted a unique key comparison of neutron fluence measurements in mono-energetic neutron fields. In contrast to former comparisons, here the fluence measurements were performed with the participants' instruments in the same neutron fields at the P.T.B. accelerator facility. Seven laboratories- the C.I.A.E. (China), I.R.M.M. (E.C.), N.M.I.J. (Japan), N.I.S.T. (USA), N.P.L. (UK), P.T.B. (Germany) and the V.N.I.I.M. (Russia)-employed their primary standard reference methods or transfer instruments carefully calibrated against their primary standards, to determine the fluence of 0.144 MeV, 1.2 MeV, 5.0 MeV and 14.8 MeV neutrons and reported calibration coefficients for a selected neutron monitor and each neutron energy with a detailed uncertainty budget for the measurements. The key comparison reference values (K.C.R.V.) were finally evaluated as the weighted mean values of the neutron fluence at 1 m distance from the target in vacuum per neutron monitor count. The uncertainties of each K.C.R.V. amounted to about 1%. The degree of equivalence (D.o.E.), defined as the deviation of the result reported by the laboratories for each energy from the corresponding K.C.R.V., and the associated expanded uncertainty are also reported. The deviations between the results of two laboratories each with the corresponding expanded uncertainties complete the documentation of the degrees of equivalence. (authors)

  3. In vitro comparison in a manikin model: increasing apical enlargement with K3 and K3XF rotary instruments.

    Science.gov (United States)

    Olivieri, Juan Gonzalo; Stöber, Eva; García Font, Marc; González, Jose Antonio; Bragado, Pablo; Roig, Miguel; Duran-Sindreu, Fernando

    2014-09-01

    The aim of the study was to compare the K3 and K3XF systems (SybronEndo, Glendora, CA) after 1 and 2 uses by evaluating apical transportation, working length loss, and working time in a manikin model. Mesial canals of 40 extracted first mandibular molars were instrumented. Radiographs taken after instrumentation with #25, #30, #35, and #40 files were superimposed on the preoperative image in both mesiodistal and buccolingual angulations. AutoCAD (Autodesk Inc, San Rafael, CA) was used to measure working length loss and apical transportation at 0, 0.5, and 1 mm from the working length (WL). The working time was measured. Group comparison was analyzed using post hoc Tukey honestly significant difference tests (P < .05). No significant differences were found in apical transportation, working length loss between K3 and K3XF systems, or between the number of uses. Significant differences were found when canal enlargement was performed to a #35-40 (P < .05). K3 instrumentation performed significantly faster (29.6 ± 15.4) than with the K3XF system (40.2 ± 17.7) (P < .05). No differences were observed in working time when comparing the number of uses. K3 and R-phase K3XF rotary systems shaped curved root canals safely with minimal apical transportation, even up to a 40/04 file. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  4. 30 CFR 56.4103 - Fueling internal combustion engines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fueling internal combustion engines. 56.4103... Prevention and Control Prohibitions/precautions/housekeeping § 56.4103 Fueling internal combustion engines. Internal combustion engines shall be switched off before refueling if the fuel tanks are integral parts of...

  5. 30 CFR 57.4103 - Fueling internal combustion engines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fueling internal combustion engines. 57.4103... Prevention and Control Prohibitions/precautions/housekeeping § 57.4103 Fueling internal combustion engines. Internal combustion engines shall be switched off before refueling if the fuel tanks are integral parts of...

  6. 30 CFR 77.1105 - Internal combustion engines; fueling.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Internal combustion engines; fueling. 77.1105 Section 77.1105 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE... COAL MINES Fire Protection § 77.1105 Internal combustion engines; fueling. Internal combustion engines...

  7. Update of the BIPM.RI(II)-K1.Rn-222 comparison of activity measurements for the radionuclide {sup 222}Rn to include the LNE-LNHB, France

    Energy Technology Data Exchange (ETDEWEB)

    Michotte, C.; Ratel, G. [Bureau International de Poids et Mesures, Pavillon de Breteuil, F-92312 Sevres cedex (France); Cassette, P. [Bureau International de Poids et Mesures, Pavillon de Breteuil, F-92312 Sevres cedex (France); Laboratoire national de metrologie et d' essais -Laboratoire national Henri Becquerel, 91191 Gif-sur-Yvette cedex (France)

    2012-02-15

    In 2007, the Laboratoire national de metrologie et d'essais - Laboratoire national Henri Becquerel (LNE-LNHB), France submitted a sample of known activity of {sup 222}Rn to the International Reference System (SIR) for comparison. The value of the activity submitted was about 90 kBq. This key comparison result joins that of Switzerland and Germany in the key comparison database that now contains three results, identifier BIPM.RI(II)-K1.Rn-222. Consequently, the KCRV has been updated and the degrees of equivalence with the KCRV have been evaluated. (authors)

  8. Design of Radial Inflow Turbine for 30 kW Microturbine

    Directory of Open Access Journals (Sweden)

    Sangsawangmatum Thanate

    2017-01-01

    Full Text Available Microturbines are small gas turbines that have the capacity range of 25-300 kW. The main components of microturbine are compressor, turbine, combustor and recuperator. This research paper focuses on the design of radial inflow turbine that operates in 30 kW microturbine. In order to operate the 30 kW microturbine with the back work ratio of 0.5, the radial inflow turbine should be designed to produce power at 60 kW. With the help of theory of turbo-machinery and the analytical methods, the design parameters are derived. The design results are constructed in 3D geometry. The 3D fluid-geometry is validated by computational fluid dynamics (CFD simulation. The simulation results show the airflow path, the temperature distribution, the pressure distribution and Mach number. According to the simulation results, there is no flow blockage between vanes and no shock flow occurs in the designed turbine.

  9. Rapid internalization of the oncogenic K+ channel K(V10.1.

    Directory of Open Access Journals (Sweden)

    Tobias Kohl

    Full Text Available K(V10.1 is a mammalian brain voltage-gated potassium channel whose ectopic expression outside of the brain has been proven relevant for tumor biology. Promotion of cancer cell proliferation by K(V10.1 depends largely on ion flow, but some oncogenic properties remain in the absence of ion permeation. Additionally, K(V10.1 surface populations are small compared to large intracellular pools. Control of protein turnover within cells is key to both cellular plasticity and homeostasis, and therefore we set out to analyze how endocytic trafficking participates in controlling K(V10.1 intracellular distribution and life cycle. To follow plasma membrane K(V10.1 selectively, we generated a modified channel of displaying an extracellular affinity tag for surface labeling by α-bungarotoxin. This modification only minimally affected K(V10.1 electrophysiological properties. Using a combination of microscopy and biochemistry techniques, we show that K(V10.1 is constitutively internalized involving at least two distinct pathways of endocytosis and mainly sorted to lysosomes. This occurs at a relatively fast rate. Simultaneously, recycling seems to contribute to maintain basal K(V10.1 surface levels. Brief K(V10.1 surface half-life and rapid lysosomal targeting is a relevant factor to be taken into account for potential drug delivery and targeting strategies directed against K(V10.1 on tumor cells.

  10. 76 FR 38448 - In the Matter of International Poultry Co., Inc. (n/k/a Carley Enterprises, Inc.), International...

    Science.gov (United States)

    2011-06-30

    ... SECURITIES AND EXCHANGE COMMISSION [File No. 500-1] In the Matter of International Poultry Co., Inc. (n/k/a Carley Enterprises, Inc.), International Thoroughbred Breeders, Inc., Internet Marketing..., Inc. (n/k/a Salus Labs International, Inc.), Itemus, Inc., and ITIS Holdings, Inc. ; Order of...

  11. KEY COMPARISON: Report on the Regional Comparison COOMET.AUV.A-K3

    Science.gov (United States)

    Barrera-Figueroa, Salvador; Nielsen, Lars; Rasmussen, Knud

    2007-01-01

    COOMET.AUV.A-K3 is a Regional Comparison that supplements the Key Comparison CCAUV.A-K3 organized by the CCAUV. The participating NMIs are GUM (Poland), INM (Romania), VNIIFTRI (Russia) and DP-NDI 'Systema' (Ukraine). The role of Pilot laboratory was undertaken by DPLADFM (Denmark). The measurements took place between May 2005 and February 2006. The time schedule was organized in a single star configuration. Initially, two LS2aP microphones were circulated. However, a sudden change of sensitivity of one of them forced the inclusion of an additional microphone. Nevertheless, the analysis was performed on all microphones involved. This report includes the measurement results from the participants, information about their calibration methods, and the analysis leading to the assignation of degrees of equivalence and the link to the CCAUV.A-K3. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  12. Final report on the key comparison CCPR-K5: Spectral diffuse reflectance

    Science.gov (United States)

    Nadal, Maria; Eckerle, Kenneth L.; Early, Edward A.; Ohno, Yoshi

    2013-01-01

    The CCPR K5 key comparison on spectral diffuse reflectance was carried out in the framework of the CIPM Mutual Recognition Arrangement, by 13 national metrology institutes (MMIs) as participants. The participants were CSIR-NML (South Africa), HUT (Finland), IFA-CSIC (Spain), KRISS (Republic of Korea), MSL (New Zealand), NIM (China), NIST (United States of America), NMIJ (Japan), NPL (United Kingdom), NRC (Canada), OMH (Hungary), PTB (Germany) and VNIIOFI (Russia Federation). NIST (USA) piloted the comparison. The aim of this comparison was to check the agreement of measurement of the spectral diffuse reflectance among participants, using the measurement geometry of d/0 or 0/d in the wavelength range of 360 nm to 820 nm at 20 nm increment. The comparison was a star type comparison with the samples provided by the pilot laboratory and with the measurement sequence: Pilot-Participant-Pilot. Spectralon and matte white ceramic tiles were used as the transfer standards. Each participant received three of each type of sample and at least one sample of each type was measured three times on three separate days, and the other two samples were measured once. The report presents the description of the measurement facilities, procedures and uncertainties of all the participants as well as the results of the comparison. Measurement results from the participants and their associated uncertainties were analyzed in accordance with the Guidelines for CCPR Key Comparison Report Preparation, using weighted mean with cut-off. For the calculation of the Key Comparison Reference Value (KCRV), as agreed by the participants, the data of both samples were used for the 460 nm to 820 nm region and only the data of the Spectralon samples were used in the spectral region of 360 nm to 440 nm. The unilateral degrees of equivalence (DoE) calculated for each participant are mostly consistent within the uncertainty (k = 2) of the DoE. This international comparison of spectral diffuse reflectance

  13. Comparison of relative INAA and k0-INAA using soil and sediment reference materials

    International Nuclear Information System (INIS)

    Jacimovic, R.

    2014-01-01

    The objective of this work was to compare the results obtained by the relative INAA and k 0 -INAA methods for the same input parameters (sample mass, nuclear data, net peak area for the same gamma line and the same measurement and same cooling and measurement times). In total eight environmental soil and sediment reference materials (RM) or certified reference materials (CRM) from different producers were analysed. In this work only the recommended or certified values were considered, allowing comparison of the two methods for 30 elements. The results point out that k 0 -INAA possesses superior qualities compared to relative INAA, being insensitive to flux gradients, and independent of recommended/certified values in RMs/CRMs, often used as standards in relative INAA. (author)

  14. A fast 30 kV 5 kHz repetition rate resonant capacitor charger

    NARCIS (Netherlands)

    Beckers, F.J.C.M.; Huiskamp, T.; van Heesch, E.J.M.; Pemen, A.J.M.

    2016-01-01

    A novel circuit topology of a fast 30 kV resonant capacitor charger is presented in this paper. The charger is designed for high repetition rate spark gap based pulsed power modulators. A spark gap can fire spontaneously (pre-firing) during charging of a capacitor bank due to poor dielectric

  15. Ranking health between countries in international comparisons

    DEFF Research Database (Denmark)

    Brønnum-Hansen, Henrik

    2014-01-01

    Cross-national comparisons and ranking of summary measures of population health sometimes give rise to inconsistent and diverging conclusions. In order to minimise confusion, international comparative studies ought to be based on well-harmonised data with common standards of definitions and docum......Cross-national comparisons and ranking of summary measures of population health sometimes give rise to inconsistent and diverging conclusions. In order to minimise confusion, international comparative studies ought to be based on well-harmonised data with common standards of definitions...

  16. 30th International Acoustical Imaging Symposium

    CERN Document Server

    Jones, Joie; Lee, Hua

    2011-01-01

    The International Symposium on Acoustical Imaging is a unique forum for advanced research, covering new technologies, developments, methods and theories in all areas of acoustics. This interdisciplinary Symposium has been taking place every two years since 1968. In the course of the years the proceedings volumes in the Acoustical Imaging Series have become a reference for cutting-edge research in the field. In 2009 the 30th International Symposium on Acoustical Imaging was held in Monterey, CA, USA, March 1-4. Offering both a broad perspective on the state-of-the-art as well as  in-depth research contributions by the specialists in the field, this Volume 30 in the Series contains an excellent collection of forty three papers presented in five major categories: Biomedical Imaging Acoustic Microscopy Non-Destructive Evaluation Systems Analysis Signal Analysis and Image Processing Audience Researchers in medical imaging and biomedical instrumentation experts.

  17. Optimasi Tablet Levofloksasin yang Mengandung Bahan Pengikat PVP K-30 dan Disintegran Vivasol

    Directory of Open Access Journals (Sweden)

    Dina Ayu Fatmawati

    2017-12-01

    Full Text Available The aim of this research was to get optimal formula of levofloxacin tablet prepared with variation of PVP K-30 as binder and vivasol as disintegrant. The making of levofloxacin tablets was done by wet granulation. Tablet was prepared with various levels of PVP K-30 and disintegrant vivasol, compressed using a hydraulic press with 12 mm punch diameter, for 3 seconds. Physical quality (hardness, friability, and disintegration time and dissolution rate of tablet was evaluated. The optimization of the formula was done by factorial design of 22 factorial experiments with 2 factors (PVP K-30 and vivasol and 2 levels (2% and 4%. Optimization results showed that elevated levels of PVP K-30 increased tablet hardness, reduced friability of tablet, decreased disintegrating time, and increased dissolution rate of levofloxacin tablets. Meanwhile, elevated levels of vivasol increased the hardness of tablets, decreased the disintegrating time of tablets, decreased the dissolution rate of levofloxacin tablets, but did not affect the friability of tablets. In conclusion, the optimal tablet that meet the specifications of physical quality (hardness, friability, and disintegrating time and dissolution rate was made by 2.4 to 3.7% of PVP K-30 and 2.0 to 3.2% vivasol as shown in the feasible area of design space.

  18. Internal 40K radiation dose to Indians

    International Nuclear Information System (INIS)

    Ranganathan, S.; Someswara Rao, M.; Nagaratnam, A.; Mishra, U.C.

    2002-01-01

    A group of 350 Indians from both sexes (7-65 years) representing different regions of India was studied for internal 40 K radiation dose from the naturally occurring body 40 K, which was measured in the National Institute of Nutrition (NIN) whole-body counter. Although the 40 K radioactivity reached a peak value by 18 years in female (2,412 Bq) and by 20 years in male (3,058 Bq) and then varied inversely with age in both sexes, the radiation dose did not show such a trend. Boys and girls of 11 years had annual effective dose of nearly 185 mSv, which decreased during adolescence (165 mSv), increased to 175 mSv by 18-20 years in adults and decreased progressively on further ageing to 99 mSv in males and 69 mSv in females at 65 years. The observed annual effective dose (175 mSv) of the young adults was close to that of the ICRP Reference Man (176 mSv) and Indian Reference Man (175 mSv). With a mean specific activity of 55 Bq/kg for the subjects and a conversion coefficient close to 3 mSv per annum per Bq/kg, the average annual effective dose from the internal 40 K turned out to be 165 mSv for Indians. (author)

  19. Final report of APMP.QM-S6: clenbuterol in porcine meat

    Science.gov (United States)

    Sin, D. W.-M.; Ho, C.; Yip, Y.-C.

    2016-01-01

    At the CCQM Organic Analysis Working Group (OAWG) Meeting held in April 2012 and the APMP TCQM Meeting held in November 2012, an APMP supplementary comparison (APMP.QM-S6) on the determination of clenbuterol in porcine meat was supported by the OAWG and APMP TCQM. This comparison was organized by the Government Laboratory, Hong Kong. In order to accommodate a wider participation, a pilot study (APMP.QM-P22) was run in parallel to APMP.QM-S6. This study provided the means for assessing the measurement capabilities for determination of low-polarity measurands in a procedure that requires extraction, clean-up, analytical separation, and selective detection in a food matrix. A total of 7 institutes registered for the supplementary comparison and 6 of them submitted their results. 4 results were included for SCRV calculation. All participating laboratories applied Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry (ID-LCMS/MS) technique with clenbuterol-d9 as internal standard spiked for quantitation in this programme. KEY WORDS FOR SEARCH APMP.QM-S6 and Clenbuterol Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Design and operational experience and testing of 50 kW/120 kHz oscillator for 3 MeV, 30 kW DC accelerator

    International Nuclear Information System (INIS)

    Srivastava, S.K.; Bakhtsingh, R.I.; Saroj, P.C.

    2011-01-01

    A 3 MeV, 30 kW dc industrial electron beam Accelerator is being developed at EBC, Kharghar, Navi Mumbai. The 3 MV dc is generated by parallel coupled voltage multiplier operating at 120 kHz. This requires an input voltage of 150 kV-0-150 kV at 120 kHz. This is achieved by 50 kW/120 kHz power oscillator in conjunction with a tuned air-core step-up transformer. Input primary voltage of 6 kV-0-6 kV at 120 kHz is generated by an oscillator using BW1121J2 water cooled triodes in push-pull Colpitts configuration. The tank circuit for the oscillator is formed by the secondary winding inductance of the step-up transformer and capacitance formed by RF feeder electrodes of the voltage multiplier column. Grid feedback for the oscillator is derived by arranging a set of electrodes in the feeder assembly in a capacitive divider configuration. The oscillator is operated in class-C mode with grid leak bias for better efficiency which also has the advantages of self-adjustment with varying load conditions. High power test has been conducted in a simulated test set-up on dummy load up to 30kW. Subsequently, the power oscillator has been tested with HV multiplier at 1MeV level satisfactorily. This paper describes the design, test results and operational experiences of the oscillator. (author)

  1. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the NSAI NML (Ireland) and the BIPM

    Science.gov (United States)

    Rolland, B.; Fletcher, N.; Power, O.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the NSAI NML (Ireland) and the BIPM carried out in 2014-2015. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the NSAI NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainties (95% confidence, k = 2) of 0.16 × 10-6 for 1 Ω and 0.42 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Development of a primary method for the determination of iron in serum

    International Nuclear Information System (INIS)

    Palos, Marie; Del Castillo Busto, Maria Estela; Fisicaro, Paola; Vaslin-Reimann, Sophie; Hattchouel, Jean-Marc; Pannier, Florence

    2015-01-01

    This work presents the development of a reference method by ICP-MS for the determination of iron in serum. To ensure the metrological traceability of the results, isotope dilution associated with ICP-MS (ID-ICP-MS) has been applied, which has the potential to be a primary measurement procedure. Method validation has been demonstrated through the use of a certified reference material (SRM 1598a) and the participation in an international comparison between National Metrology Institutes (BIPM-CCQM K107). The validated method is now available to support clinical laboratories in the evaluation of their measurement capabilities and for quality assurance and quality control programs. In fact, this ID-ICP-MS method can be used to certify reference materials or to assign reference values to samples used in proficiency testing schemes. The feasibility has been tested on two unknown samples, i.e. BCR"R -637, IRMM sample and an ANSM B17 sample (a material distributed during a National Quality Control program). (authors)

  3. Identification and Characterization of 30K Protein Genes Found in Bombyx mori (Lepidoptera: Bombycidae) Transcriptome

    Science.gov (United States)

    Shi, Xiao-Feng; Li, Yi-Nü; Yi, Yong-Zhu; Xiao, Xing-Guo; Zhang, Zhi-Fang

    2015-01-01

    The 30K proteins, the major group of hemolymph proteins in the silkworm, Bombyx mori (Lepidoptera: Bombycidae), are structurally related with molecular masses of ∼30kDa and are involved in various physiological processes, e.g., energy storage, embryonic development, and immune responses. For this report, known 30K protein gene sequences were used as Blastn queries against sequences in the B. mori transcriptome (SilkTransDB). Twenty-nine cDNAs (Bm30K-1–29) were retrieved, including four being previously unidentified in the Lipoprotein_11 family. The genomic structures of the 29 genes were analyzed and they were mapped to their corresponding chromosomes. Furthermore, phylogenetic analysis revealed that the 29 genes encode three types of 30K proteins. The members increased in each type is mainly a result of gene duplication with the appearance of each type preceding the differentiation of each species included in the tree. Real-Time Quantitative Polymerase Chain Reaction (Q-PCR) confirmed that the genes could be expressed, and that the three types have different temporal expression patterns. Proteins from the hemolymph was separated by SDS-PAGE, and those with molecular mass of ∼30kDa were isolated and identified by mass spectrometry sequencing in combination with searches of various databases containing B. mori 30K protein sequences. Of the 34 proteins identified, 13 are members of the 30K protein family, with one that had not been found in the SilkTransDB, although it had been found in the B. mori genome. Taken together, our results indicate that the 30K protein family contains many members with various functions. Other methods will be required to find more members of the family. PMID:26078299

  4. Comparison in the calculation of committed effective dose using the ICRP 30 and ICRP 60 models for a repeated incorporation by inhalation of I-125

    International Nuclear Information System (INIS)

    Carreno P, A.L.; Cortes C, A.; Alonso V, G.; Serrano P, F.

    2005-01-01

    Presently work, a comparison in the calculation of committed effective dose using the models of the ICRP 30 and those of the ICRP 60 for the analysis of internal dose due to repeated incorporation of I-125 is shown. The estimations of incorporated activity are obtained starting from the proportionate data for an exercise of inter comparison, with which it should be determined the internal dose later on. For to estimate the initial activity incorporated by repeated dose was assumed that this it was given through of multiple individual incorporations which happened in the middle points of the monitoring periods. The results using the models of the ICRP 30 and of the ICRP 60 are compared and the causes of the differences are analyzed. (Author)

  5. Comparison of working length control consistency between hand K-files and Mtwo NiTi rotary system.

    Science.gov (United States)

    Krajczár, Károly; Varga, Enikő; Marada, Gyula; Jeges, Sára; Tóth, Vilmos

    2016-04-01

    The purpose of this study was to investigate the consistency of working length control between hand instrumentation in comparison to engine driven Mtwo nickel-titanium rotary files. Forty extracted maxillary molars were selected and divided onto two parallel groups. The working lengths of the mesiobuccal root canals were estimated. The teeth were fixed in a phantom head. The root canal preparation was carried out group 1 (n=20) with hand K-files, (VDW, Munich, Germany) and group 2 (n=20) with Mtwo instruments (VDW, Munich, Germany). Vestibulo-oral and mesio-distal directional x-ray images were taken before the preparation with #10 K-file, inserted into the mesiobuccal root canal to the working length, and after preparation with #25, #30 and #40 files. Working lenght changes were detected with measurements between the radiological apex and the instrument tips. In the Mtwo group a difference in the working competency (protary files. Mtwo NiTi rotary file did therefore proved to be more accurate in comparison to the conventional hand instrumentation. Working length, Mtwo, nickel-titanium, hand preparation, engine driven preparation.

  6. Comparison of in-hospital versus 30-day mortality assessments for selected medical conditions.

    Science.gov (United States)

    Borzecki, Ann M; Christiansen, Cindy L; Chew, Priscilla; Loveland, Susan; Rosen, Amy K

    2010-12-01

    In-hospital mortality measures such as the Agency for Healthcare Research and Quality (AHRQ) Inpatient Quality Indicators (IQIs) are easily derived using hospital discharge abstracts and publicly available software. However, hospital assessments based on a 30-day postadmission interval might be more accurate given potential differences in facility discharge practices. To compare in-hospital and 30-day mortality rates for 6 medical conditions using the AHRQ IQI software. We used IQI software (v3.1) and 2004-2007 Veterans Health Administration (VA) discharge and Vital Status files to derive 4-year facility-level in-hospital and 30-day observed mortality rates and observed/expected ratios (O/Es) for admissions with a principal diagnosis of acute myocardial infarction, congestive heart failure, stroke, gastrointestinal hemorrhage, hip fracture, and pneumonia. We standardized software-calculated O/Es to the VA population and compared O/Es and outlier status across sites using correlation, observed agreement, and kappas. Of 119 facilities, in-hospital versus 30-day mortality O/E correlations were generally high (median: r = 0.78; range: 0.31-0.86). Examining outlier status, observed agreement was high (median: 84.7%, 80.7%-89.1%). Kappas showed at least moderate agreement (k > 0.40) for all indicators except stroke and hip fracture (k ≤ 0.22). Across indicators, few sites changed from a high to nonoutlier or low outlier, or vice versa (median: 10, range: 7-13). The AHRQ IQI software can be easily adapted to generate 30-day mortality rates. Although 30-day mortality has better face validity as a hospital performance measure than in-hospital mortality, site assessments were similar despite the definition used. Thus, the measure selected for internal benchmarking should primarily depend on the healthcare system's data linkage capabilities.

  7. EURAMET.T-K7 Key Comparison of Water Triple-Point Cells

    Science.gov (United States)

    Peruzzi, A.; Bosma, R.; Kerkhof, O.; Rosenkranz, P.; Del Campo Maldonado, M. D.; Strnad, R.; Nielsen, J.; Anagnostou, M.; Veliki, T.; Zvizdic, D.; Grudnewicz, E.; Nedea, M.; Neagu, D. M.; Steur, P.; Filipe, E.; Lobo, I.; Antonsen, I.; Renaot, E.; Heinonen, M.; Weckstrom, T.; Bojkovski, J.; Turzo-Andras, E.; Nemeth, S.; White, M.; Tegeler, E.; Dobre, M.; Duris, S.; Kartal Dogan, A.; Uytun, A.; Augevicius, V.; Pauzha, A.; Pokhodun, A.; Simic, S.

    2011-12-01

    The results of a EURAMET key comparison of water triple-point cells (EURAMET.T-K7) are reported. The equipment used, the measuring conditions applied, and the procedures adopted for the water triple-point measurement at the participating laboratories are synthetically presented. The definitions of the national reference for the water triple-point temperature adopted by each laboratory are disclosed. The multiplicity of degrees of equivalence arising for the linking laboratories with respect to the "mother" comparison CCT-K7 is discussed in detail.

  8. The neural correlates of internal and external comparisons: an fMRI study.

    Science.gov (United States)

    Wen, Xue; Xiang, Yanhui; Cant, Jonathan S; Wang, Tingting; Cupchik, Gerald; Huang, Ruiwang; Mo, Lei

    2017-01-01

    Many previous studies have suggested that various comparisons rely on the same cognitive and neural mechanisms. However, little attention has been paid to exploring the commonalities and differences between the internal comparison based on concepts or rules and the external comparison based on perception. In the present experiment, moral beauty comparison and facial beauty comparison were selected as the representatives of internal comparison and external comparison, respectively. Functional magnetic resonance imaging (fMRI) was used to record brain activity while participants compared the level of moral beauty of two scene drawings containing moral acts or the level of facial beauty of two face photos. In addition, a physical size comparison task with the same stimuli as the beauty comparison was included. We observed that both the internal moral beauty comparison and external facial beauty comparison obeyed a typical distance effect and this behavioral effect recruited a common frontoparietal network involved in comparisons of simple physical magnitudes such as size. In addition, compared to external facial beauty comparison, internal moral beauty comparison induced greater activity in more advanced and complex cortical regions, such as the bilateral middle temporal gyrus and middle occipital gyrus, but weaker activity in the putamen, a subcortical region. Our results provide novel neural evidence for the comparative process and suggest that different comparisons may rely on both common cognitive processes as well as distinct and specific cognitive components.

  9. Characterization and testing of 30 kV, 60 kW electron optical column for melting applications

    Energy Technology Data Exchange (ETDEWEB)

    Baibhaw, Prakash; Gupta, Sachin; Malik, Pravanjan, E-mail: bprakash@barc.gov.in [Bhabha Atomic Research Centre, Mumbai (India)

    2014-07-01

    High energy electron beams (30-150 keV) are widely used as intense heat source in welding, melting and evaporation of refractory metals. These operations are mostly carried out in high vacuum (10{sup -4}-10{sup -5} mbar) to aid unimpeded flow of electrons from generation to the point of application. A 30 kV, 60 kW Electron beam optical column (EOC) is designed and developed under the high power beam technology programme. The optical column consists of an electron gun and twin electromagnetic focusing lenses. The heating power of emitter, gun perveance, grid voltage control, beam focusing with the twin electromagnetic lenses and beam spot size measurements are reported in this paper. The results are compared with the design values. Operational issues during the high power melting and the strategy for automation of the electron gun are discussed. (author)

  10. Micro Foundations for International Productivity Comparisons

    NARCIS (Netherlands)

    Gersbach, Hans; Ark, Bart van

    1994-01-01

    This paper describes the methodology and procedures of international comparisons of productivity levels for twelve manufacturing industries (producing food products, beer, soap and detergents, iron and steel, machine tools, various types of machinery, computers, audio and video equipment, industrial

  11. Characterization and physical stability of spray dried solid dispersions of probucol and PVP-K30

    DEFF Research Database (Denmark)

    Thybo, Pia; Pedersen, Betty L; Hovgaard, Lars

    2008-01-01

    The main purpose of this study was to obtain stable, well-characterized solid dispersions (SDs) of amorphous probucol and polyvinylpyrrolidone K-30 (PVP-K30) with improved dissolution rates. A secondary aim was to investigate the flow-through dissolution method for in-vitro dissolution measuremen...

  12. University Competencies Quality Management: from Self-Assessment to International Comparison

    Directory of Open Access Journals (Sweden)

    Denys Ilnytskyy

    2017-03-01

    Full Text Available The article represents a methodological summary of the main levels, tools, approaches and subjects of the use of assessment in educational activity with an emphasis on the university-based dimension. It has been revealed that the use of assessment as one of the tools for quality management has both internal (self-assessment and external dimensions (variety of tools, which is widespread in universities in the field of implementation of educational programs that have a competency-based dimension. The deep integration of assessment components into a competency-based model for the US labour force development system, as well as the disposition of assessment in the system of competencies in the national qualifications framework in higher education, which are characteristic for the European countries, have been identified. It has been demonstrated that the educational trajectory of personality training throughout life and career development is encountered at various stages with a variety of assessment tools. The comparative characteristics of pre-university assessment, certification programs of global assessment, external assessment of applicants and graduates, and persons aged 30+, functioning of accreditation agencies and agencies of professional accreditation, international rating, international comparisons of education quality, are given. It is proved that the necessity to bear costs for conducting international comparisons, national and international ratings is conditioned not only by the impact of the internationalization of educational activities and the globalization of the world economy, but primarily by the desire to ensure the highest quality of educational services, provided by leaders, and their high average level within the national educational systems. The results are broadly illustrated by evidence and examples from the developed countries (mainly the United States and Ukraine. Based on the research of the attitude of students and

  13. Neutron activation analysis: A primary method of measurement

    Energy Technology Data Exchange (ETDEWEB)

    Greenberg, Robert R., E-mail: robert.greenberg@nist.gov [National Institute of Standards and Technology, Gaithersburg, MD 20899-8395 (United States); Bode, Peter, E-mail: p.bode@tudelft.nl [Delft University of Technology, Delft (Netherlands); De Nadai Fernandes, Elisabete A., E-mail: lis@cena.usp.br [Centro de Energia Nuclear na Agricultura, Universidade de Sao Paulo, Piracicaba, SP (Brazil)

    2011-03-15

    Neutron activation analysis (NAA), based on the comparator method, has the potential to fulfill the requirements of a primary ratio method as defined in 1998 by the Comite Consultatif pour la Quantite de Matiere - Metrologie en Chimie (CCQM, Consultative Committee on Amount of Substance - Metrology in Chemistry). This thesis is evidenced in this paper in three chapters by: demonstration that the method is fully physically and chemically understood; that a measurement equation can be written down in which the values of all parameters have dimensions in SI units and thus having the potential for metrological traceability to these units; that all contributions to uncertainty of measurement can be quantitatively evaluated, underpinning the metrological traceability; and that the performance of NAA in CCQM key-comparisons of trace elements in complex matrices between 2000 and 2007 is similar to the performance of Isotope Dilution Mass Spectrometry (IDMS), which had been formerly designated by the CCQM as a primary ratio method.

  14. Internal conversion coefficients for atomic numbers Z less than or equal to 30

    International Nuclear Information System (INIS)

    Band, I.M.; Trzhaskovskaya, M.B.; Listengarten, M.A.

    1976-01-01

    Presented here are internal conversion coefficients (ICC) of gamma rays for 20 values of atomic number, Z, in the range 3 less than or equal to Z less than or equal to 30, including all Z greater than or equal to 14. The tables provide the previously missing data for light elements. Coefficients are given for 19 values of gamma-ray transition energies up to 6 MeV for the K-electron shell and 18 values up to 2 MeV for three L-subshells. The minimum enegy is 15 keV. The first five electric and magnetic nuclear transition multipolarities are covered. The calculations are relativistic, with screening and finite nuclear size effect taken into account

  15. Activity measurements of the radionuclide {sup 111}In for the LNE-LNHB, France in the ongoing comparison BIPM.RI(II)-K1.In-111

    Energy Technology Data Exchange (ETDEWEB)

    Michotte, C.; Ratel, G.; Courte, S. [Bureau International des Poids et Mesures (BIPM), Pavillon de Breteuil, 92 - Sevres (France); Verdeau, E.; Amiot, M.N. [Laboratoire national de metrologie et d' essais-Laboratoire National Henri Becquerel (LNE-LNHB), 91 - Gif-sur-Yvette (France)

    2010-10-15

    In 2006, the Laboratoire national de metrologie et d'essais - Laboratoire national Henri Becquerel (LNE-LNHB) submitted a sample of known activity of {sup 111}In to the International Reference System (SIR). The value of the activity submitted was about 14 MBq. This provides a new result for France in the matrix of degrees of equivalence in the key comparison database that enables them to maintain their degrees of equivalence for this radionuclide. The key comparison reference value has been re-evaluated and the comparison, identifier BIPM.RI(II)-K1.In-111, now contains five valid results. (authors)

  16. International price comparisons for pharmaceuticals. Measurement and policy issues.

    Science.gov (United States)

    Danzon, P M; Kim, J D

    1998-01-01

    Cross-national price comparisons for pharmaceuticals are commonly used for two purposes. Comparisons based on a sample of products are used to draw conclusions about differences in average price levels. Cross-national comparisons applied to individual products are also used by governments to set domestic prices. This paper examines the major methodological issues raised by international price comparisons, focusing on measurement of differences in average price levels and the validity of policy conclusions drawn from such price comparison studies. It argues that valid measures of average price levels can only be obtained from comparisons based on a comprehensive or representative sample of products, appropriately weighted, following standard index number methods. Comparisons of individual product prices should take into account the manufacturer's entire product portfolio over time rather than focus narrowly on a single product at a point in time. Because of the great variation across countries in both the range of drug compounds available and the dosage forms, strengths and pack sizes for each compound, obtaining a broadly comprehensive or representative sample is problematical. If products are required to match on all dimensions, including molecule, manufacturer, strength and pack, as is common in most international price comparisons, then only a very small and unrepresentative sample of the drugs available in each country can be included in the analysis. A trade-off between the desire to compare only identical products and the need to compare a truly representative sample of a country's pharmaceutical market is therefore necessary. A valid comparison of average drug prices should include generics and over-the-counter products that are good substitutes for branded prescription drugs, with all forms, strengths and packs. To achieve this broad representation, however, the requirements of same manufacturer, same brand, dosage form, strength and pack size must be

  17. Update of the ongoing comparison BIPM.RI(II)-K1.Se-75 to include recent activity measurements of the radionuclide {sup 75}Se by the LNE-LNHB (France)

    Energy Technology Data Exchange (ETDEWEB)

    Michotte, C.; Courte, S.; Ratel, G. [Bureau International des Poids et Mesures (BIPM), Pavillon de Breteuil, F-92312 Sevres cedex (France); Moune, M.; Bobin, C. [Laboratoire national de metrologie et d' essais-Laboratoire National Henri Becquerel (LNE-LNHB), Gif-sur-Yvette Cedex (France)

    2011-06-15

    In 2006, to update their previous result of 1992, the LNE-LNHB submitted a new sample of {sup 75}Se with an activity of about 2.2 MBq to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). This comparison has the identifier BIPM.RI(II)-K1.Se-75. The degree of equivalence between the equivalent activity measured in the SIR for the new LNE-LNHB sample and the updated key comparison reference value (KCRV) has been calculated, as have the degrees of equivalence with each of the other participants. The results are given in the form of a matrix and a graphical presentation is also given. (authors)

  18. A comparison of latent class, K-means, and K-median methods for clustering dichotomous data.

    Science.gov (United States)

    Brusco, Michael J; Shireman, Emilie; Steinley, Douglas

    2017-09-01

    The problem of partitioning a collection of objects based on their measurements on a set of dichotomous variables is a well-established problem in psychological research, with applications including clinical diagnosis, educational testing, cognitive categorization, and choice analysis. Latent class analysis and K-means clustering are popular methods for partitioning objects based on dichotomous measures in the psychological literature. The K-median clustering method has recently been touted as a potentially useful tool for psychological data and might be preferable to its close neighbor, K-means, when the variable measures are dichotomous. We conducted simulation-based comparisons of the latent class, K-means, and K-median approaches for partitioning dichotomous data. Although all 3 methods proved capable of recovering cluster structure, K-median clustering yielded the best average performance, followed closely by latent class analysis. We also report results for the 3 methods within the context of an application to transitive reasoning data, in which it was found that the 3 approaches can exhibit profound differences when applied to real data. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  19. Simulation and optimization of Corona Rings for 300 kV, 120 kHz RF transformer for 3 MeV, 30 kW DC accelerator

    International Nuclear Information System (INIS)

    Das, Swati H.; Dewangan, S.; Sharma, D.K.

    2015-01-01

    The 3 MeV, 30 kW Industrial DC Electron Beam Accelerator with a terminal voltage of 3 MV is designed, developed and housed inside the Electron Beam Centre (EBC) building at Kharghar, Navi Mumbai. The accelerator requires an input voltage of 150 kV-0-150 kV at 120 kHz which is generated by tuned air-core step- up toroidal transformer. The Transformer is rated for 6 kV-0-6 kV primary and 150 kV-0-150 kV secondary at 120 kHz working at 6 kg/cm''2 SF 6 gas environment. Secondary is wound over the perforated insulator former, To limit the electric stress to 5-7 kV/cm on the insulator surface and 120 kV/cm in SF 6 , transformer was simulated in CST EM studio for electric field analysis. Parametric simulations were done to optimize the dimensions and design of corona rings at the High voltage terminals. Simulation results are described in this paper briefly. (author)

  20. Report on EUROMET.RI(I)-K1 and EUROMET.RI(I)-K4 (EUROMET project no. 813): Comparison of air kerma and absorbed dose to water measurements of 60Co radiation beams for radiotherapy

    International Nuclear Information System (INIS)

    Csete, I.; Leiton, A.G.; Sochor, V.; Lapenas, A.; Grindborg, J.E.; Jokelainen, I.; Bjerke, H.; Dobrovodsky, J.; Megzifene, A.; Hourdakis, C.J.; Ivanov, R.; Vekic, B.; Kokocinski, J.; Cardoso, J.; Buermann, L.; Tiefenboeck, W.; Stucki, G.; Van Dijk, E.; Toni, M.P.; Minniti, R.; McCaffrey, J.P.; Silva, C.N.M.; Kharitonov, I.; Webb, D.; Saravi, M.; Delaunay, F.

    2010-01-01

    The results of an unprecedented international effort involving 26 countries are reported. The EUROMET.RI(I)-K1 and EUROMET.RI(I)-K4 key comparisons were conducted with the goal of supporting the relevant calibration and measurement capabilities (CMC) planned for publication by the participant laboratories. The measured quantities were the air kerma (K air ) and the absorbed dose to water (Dw) in 60 Co radiotherapy beams. The comparison was conducted by the pilot laboratory MKEH (Hungary), in a star-shaped arrangement from January 2005 to December 2008. The calibration coefficients of four transfer ionization chambers were measured using two electrometers. The largest deviation between any two calibration coefficients for the four chambers in terms of air kerma and absorbed dose to water was 2.7% and 3.3% respectively. An analysis of the participant uncertainty budgets enabled the calculation of degrees of equivalence (DoE), in terms of the deviations of the results and their associated uncertainties. As a result of this EUROMET project 813 comparison, the BIPM key comparison database (KCDB) will include eleven new Kair and fourteen new D w DoE values of European secondary standard dosimetry laboratories (SSDLs), and the KCDB will be updated with the new DoE values of the other participant laboratories. The pair-wise degrees of equivalence of participants were also calculated. In addition to assessing calibration techniques and uncertainty calculations of the participants, these comparisons enabled the experimental determinations of N Dw /N Kair ratios in the 60 Co gamma radiation beam for the four radiotherapy transfer chambers. (authors)

  1. 76 FR 35259 - Samaritan Pharmaceuticals, Inc., Seaena, Inc., Seirios International, Inc. (f/k/a Exactly...

    Science.gov (United States)

    2011-06-16

    ...., Seirios International, Inc. (f/k/a Exactly Sportswear, Inc.), et al.; Order of Suspension of Trading June... Sportswear, Inc.), Sento Corp., Shoe Pavilion, Inc., Silver Eagle Resources Ltd. (n/k/a Mercator Minerals Ltd... concerning the securities of Seirios International, Inc. (f/k/a Exactly Sportswear, Inc.) because it has not...

  2. PENGARUH POLIVINILPIROLIDON K-30 TERHADAP PENINGKATAN LAJU DISOLUSI ANDROGRAFOLIDA DENGAN SISTEM DISPERSI SOLIDA

    Directory of Open Access Journals (Sweden)

    Suharmiati Suharmiati

    2012-11-01

    Full Text Available Andrographolide is the main constituent of Andrographis paniculata Ness which was poorly soluble in water. As diterpenoid lactone andrographolide has many biological activity, some of them ara immunostimulant, antimalaria, hepatoprotector and anti mutagenic. The objectives of this study were to find out influence of polyvinylpirrolidon (PVP K-30 to increase dissolution rate of andrographolide by solid dispersion in water and dissolution media pH 8,0. In this research andrographolide were divided in 6 groups that are physical mixture and solid dispersion by ratio 1:3; 1:5 and 1:9. Result of these study showed that the X-ray difraction patterns of physical mixture have crystal intensity as same as andrographolide crystal. But solid dispersion showed lower intensity. The solid dispersion system increase dissolution rate of andrographolide isolate. Increasing of dissolution rate a function of the ratio of drug to PVP used. Studies of dissolution rate have shown that coprecipitate of andrographolide-PVP K-30 (1:9 is better combination than 1:5 and 1:3.   Keywords: andrographolide, PVP K-30, solid dispersion and dissolution rate

  3. Safety Evaluation of 30 kGy Irradiated Chocolate Ice Cream

    International Nuclear Information System (INIS)

    Jeon, Y.E.; Yin, X.F.; Chung, C.K.; Kang, I.J.

    2013-01-01

    This study was investigated the potential toxicity of gamma-irradiated chocolate ice cream for its future use in space. Chocolate ice cream was irradiated at a dose of 30 kGy at a temperature of -20°C. For the animal study, AIN-93G was used as a control diet and irradiated and non-irradiated chocolate ice cream diets were administered to male and female ICR mice (ten mice per group) for three months. During the experimental period, the group fed irradiated chocolate ice cream did not show any changes in appearance, behavior, mortality, body weight, organ weight, or food consumption compared to the control. Also, all biochemical parameters, including hematology profiles, erythrocyte counts, and serum biochemical values were in normal ranges. In histopathological examinations of liver and kidney tissues, there were no significant differences between the control group and the group fed irradiated chocolate ice cream. These results indicate that chocolate ice cream irradiated at 30 kGy did not cause any toxic effects and could be applied for the development of safe and hygienic space food

  4. International Comparisons: Issues of Methodology and Practice

    Directory of Open Access Journals (Sweden)

    Serova Irina A.

    2017-12-01

    Full Text Available The article discusses the methodology and organization of statistical observation of the level of countries’ economic development. The theoretical basis of international comparisons is singled out and on its basis the comparative evaluation of inconsistency of theoretical positions and the reasons of differences of GDP growth is carried out. Based on the complexity of the formation of homogeneous data sets in order to obtain correct comparison results, a general scheme for the relationship between the theoretical base of international comparisons and PPP constraints is defined. The possibility of obtaining a single measurement of the indicators of national economies based on the existing sampling errors, measurement uncertainties and classification errors is considered. The emphasis is placed on combining the work using the ICP and CPI with the aim of achieving comparability of data in the territorial and temporal cross-section. Using the basic characteristics of sustainable economic growth, long-term prospects for changing the ranking positions of countries with different levels of income are determined. It is shown that the clarity and unambiguity of the theoretical provisions is the defining condition for the further process of data collection and formation of correct analytical conclusions.

  5. submitter Development of a 100 kW, 12.5 kV, 22 kHz and 30 kV insulated medium frequency transformer for compact and reliable medium voltage power conversion

    CERN Document Server

    Isler, Stephane; Aguglia, Davide; Bonnin, Xavier Abel

    2017-01-01

    This paper presents the critical design aspects addressed during the development of a 100 kW, 12.5 kV, 22 kHz, and 30 kV insulated medium frequency transformer used in a power converter. The transformers are used in a resonant multilevel converter topology producing HV DC voltage from a three phase 400 V AC industrial grid. The power converter is used to supply radio frequency systems in particle accelerators. Considerations about material selection, dielectric, magnetic and thermal design are discussed and experimental results on the full scale transformer and power converter are presented.

  6. Activity measurements of the radionuclide 109Cd for the PTB, Germany and the NIST, USA in the ongoing comparison BIPM.RI(II)-K1.Cd-109

    International Nuclear Information System (INIS)

    Ratel, G.; Michotte, C.; Janssen, H.; Kossert, K.; Lucas, L.; Karam, L.

    2005-01-01

    In 2004, the Physikalisch-Technische Bundesanstalt (PTB, Germany) and the National Institute of Standards and Technology (NIST, USA) each submitted one sample of known activity of 109 Cd to the International Reference System (SIR). The PTB result replaces their previous measurement of 1994 and the NIST result updates their 1986 CCRI(II) comparison result. The values of the activity submitted were about 15 MBq and 42 MBq. The new key comparison results have replaced the earlier values in the matrix of degrees of equivalence that now contains six results, identifier BIPM.RI(II)-K1.Cd-109, to which the remaining eleven results from the CCRI(II)-K2.Cd-109 held in 1986 are still linked. (authors)

  7. Progress in organizing national and international comparisons for nuclear medicine measurements

    International Nuclear Information System (INIS)

    Sahagia, Maria; Waetjen, Anamaria C.; Ivan, Constantin

    2008-01-01

    The paper presents the progress registered by the Radionuclide Metrology Laboratory (RML) from IFIN-HH, in improvement of the quality of radiopharmaceuticals activity measurement, and assurance of the whole traceability chain from international level to the national users. The progress in organization of comparisons for radiopharmaceuticals activity measurement is analyzed. A detailed description of two recent national comparisons, and an international one, regarding 131 I solutions, within the frame of the IAEA's CRP E2.10.05 'Harmonization of quality practices for nuclear medicine radioactivity measurements' is done, with the analysis of the strong and week points in measurements. The most important outcome of the paper is the analysis of the evolution in quality of comparisons since a previously reported one. At the RML level, the improvements are: demonstration of the international equivalence of primary Romanian activity standard, improvement of the secondary standard, relevance of the comparison within the IAEA frame, implementation of a quality system in standardization and in comparisons, and implication of the RML in calibrations and metrological checks. The participants' reported improvements refer to growing of the awareness in quality of measurement and improvement of the measurement equipment. Reasons for future comparisons organization are presented. (author)

  8. Design of a high efficiency 30 kW boost composite converter

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyeokjin [Univ. of Colorado, Boulder, CO (United States); Chen, Hua [Univ. of Colorado, Boulder, CO (United States); Maksimovic, Dragan [Univ. of Colorado, Boulder, CO (United States); Erickson, Robert W. [Univ. of Colorado, Boulder, CO (United States)

    2015-09-20

    An experimental 30 kW boost composite converter is described in this paper. The composite converter architecture, which consists of a buck module, a boost module, and a dual active bridge module that operates as a DC transformer (DCX), leads to substantial reductions in losses at partial power points, and to significant improvements in weighted efficiency in applications that require wide variations in power and conversion ratio. A comprehensive loss model is developed, accounting for semiconductor conduction and switching losses, capacitor losses, as well as dc and ac losses in magnetic components. Based on the developed loss model, the module and system designs are optimized to maximize efficiency at a 50% power point. Experimental results for the 30 kW prototype demonstrate 98.5%peak efficiency, very high efficiency over wide ranges of power and voltage conversion ratios, as well as excellent agreements between model predictions and measured efficiency curves.

  9. 30th International Symposium on Shock Waves

    CERN Document Server

    Sadot, Oren; Igra, Ozer

    2017-01-01

    These proceedings collect the papers presented at the 30th International Symposium on Shock Waves (ISSW30), which was held in Tel-Aviv Israel from July 19 to July 24, 2015. The Symposium was organized by Ortra Ltd. The ISSW30 focused on the state of knowledge of the following areas: Nozzle Flow, Supersonic and Hypersonic Flows with Shocks, Supersonic Jets, Chemical Kinetics, Chemical Reacting Flows, Detonation, Combustion, Ignition, Shock Wave Reflection and Interaction, Shock Wave Interaction with Obstacles, Shock Wave Interaction with Porous Media, Shock Wave Interaction with Granular Media, Shock Wave Interaction with Dusty Media, Plasma, Magnetohyrdrodynamics, Re-entry to Earth Atmosphere, Shock Waves in Rarefied Gases, Shock Waves in Condensed Matter (Solids and Liquids), Shock Waves in Dense Gases, Shock Wave Focusing, Richtmyer-Meshkov Instability, Shock Boundary Layer Interaction, Multiphase Flow, Blast Waves, Facilities, Flow Visualization, and Numerical Methods. The two volumes serve as a reference ...

  10. Operating Reserves and Wind Power Integration: An International Comparison; Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Milligan, M.; Donohoo, P.; Lew, D.; Ela, E.; Kirby, B.; Holttinen, H.; Lannoye, E.; Flynn, D.; O' Malley, M.; Miller, N.; Eriksen, P. B.; Gottig, A.; Rawn, B.; Gibescu, M.; Lazaro, E. G.; Robitaille, A.; Kamwa, I.

    2010-10-01

    This paper provides a high-level international comparison of methods and key results from both operating practice and integration analysis, based on an informal International Energy Agency Task 25: Large-scale Wind Integration.

  11. 30 CFR 206.176 - How do I perform accounting for comparison?

    Science.gov (United States)

    2010-07-01

    ... paragraphs (b) and (c) of this section, the actual dual accounting value, for royalty purposes, is the... 30 Mineral Resources 2 2010-07-01 2010-07-01 false How do I perform accounting for comparison? 206... REVENUE MANAGEMENT PRODUCT VALUATION Indian Gas § 206.176 How do I perform accounting for comparison? (a...

  12. 7th International k0-Users' Workshop

    International Nuclear Information System (INIS)

    Borut Smodis

    2018-01-01

    Complete text of publication follows. The k 0 method of neutron activation analysis (k 0 -NAA) has become a well-established analytical tool for elemental analysis of various samples since its introduction in mid-1970s. To strengthen its development, applications and use, a series of regular workshops dedicated to this particular analytical method has been introduced twenty-five years ago, held in Astene, Belgium (1992); Ljubljana, Slovenia (1996); Bruges, Belgium (2001); Funchal, Portugal (2005); Belo Horizonte, Brazil (2009) and Budapest, Hungary (2013). The 7th k 0 -Users' Workshop was held at Hotel Novotel Montreal Centre, Canada, 3-8 September 2017. The meeting was organized by Polytechnique Montreal in cooperation with the International Atomic Energy Agency. Twenty-seven participants from 16 different countries (Australia, Austria, Belgium, Brazil, Canada, Czech Republic, Egypt, Germany, Hungary, Italy, Jamaica, Peru, Slovenia, the Netherlands, Turkey, Vietnam) from all five continents discussed the latest developments and applications of k 0 -NAA. Thirty-three papers were presented in the following sessions: Fundamentals of k 0 -NAA, Nuclear Data, Neutron Flux Parameters, k 0 -NAA Methodology, Validation of k 0 -NAA, Facilities, Automatization, and k 0 -NAA Methodology and PGAA. The talks included presentations by two Keynote Speakers and one Honorary Speaker. During the workshop, scientific visits were paid to the SLOWPOKE NAA Laboratory and Thermal Hydraulics Laboratory of the Polytechnique Montreal. The upcoming 12 papers in this issue of the Journal of Radioanalytical and Nuclear Chemistry were selected to be published from the workshop. The next, 8th k 0 -Users' Workshop is expected to be held in Ljubljana, Slovenia in 2021.

  13. Certification measurement of the cadmium, copper and lead contents in rice using isotope dilution inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Vassileva, Emilia; Quetel, Christophe R.

    2004-01-01

    This paper describes the certification of the Cd, Cu and Pb amount contents in a rice material, that were used as reference values for round 19 of the international measurement evaluation programme (IMEP). The protocol developed in this study was based on isotope dilution associated to inductively coupled plasma mass spectrometry (ID-ICP-MS). A multiple spiking approach was applied to reduce significantly the number of analytical steps. For the decomposition of the sample, three different microwave assisted digestion procedures were tested and compared. The use of hydrofluoric acid was found necessary to ensure full solubilisation and complete isotopic equilibration. Estimation of the combined uncertainty attached to the measurement results was performed according to the ISO guidelines. Contributions from the correction for moisture content, sample homogeneity, procedural blank, spike impurities, spectral interferences, instrumental background and dead-time effects were evaluated. SI-traceable values with less than 2% combined uncertainty (k = 2) were obtained for Cd, Cu and Pb, respectively, (14.39 ± 0.21) x 10 -6 mol kg -1 , (44.31 ± 0.42) x 10 -6 mol kg -1 and (2.034 ± 0.034) x 10 -6 mol kg -1 . The rice powder was observed to be highly hygroscopic and a second series of isotope dilution mass spectrometry measurements was carried out on samples in equilibrium with the ambient moisture conditions ('saturated' samples). The Comite Consultatif pour la Quantite de Matiere (CCQM) requested this approach for the participation to the key comparison 24 on the same rice test material. The excellent agreement for Cd between the IMEP-19 reference value, the value submitted by the institute for reference materials and measurements (IRMM) to CCQM-K24 and the corresponding reference value obtained as the arithmetic mean from the results of the 11 participating National Measurement Institutes (less than 0.27% difference) further validated this work. Eventually, this series

  14. Measuring psychological distress in older Aboriginal and Torres Strait Islanders Australians: a comparison of the K-10 and K-5.

    Science.gov (United States)

    McNamara, Bridgette J; Banks, Emily; Gubhaju, Lina; Williamson, Anna; Joshy, Grace; Raphael, Beverley; Eades, Sandra J

    2014-12-01

    To assess the cross-cultural validity of two Kessler psychological distress scales (K-10 and K-5) by examining their measurement properties among older Aboriginal and Torres Strait Islanders and comparing them to those in non-Aboriginal individuals from NSW Australia. Self-reported questionnaire data from the 45 and Up Study for 1,631 Aboriginal and 231,774 non-Aboriginal people were used to examine the factor structure, convergent validity, internal consistency and levels of missing data of K-10 and K-5. We found excellent agreement in classification of distress of Aboriginal participants by K-10 and K-5 (weighted kappa=0.87), high internal consistency (Cronbach's alpha K-10: 0.93, K-5: 0.88), and factor structures consistent with those for the total Australian population. Convergent validity was evidenced by a strong graded relationship between the level of distress and the odds of: problems with daily activities due to emotional problems; current treatment for depression or anxiety; and poor quality of life. K-10 and K-5 scales are promising tools for measuring psychological distress among Aboriginal and Torres Strait Islanders aged 45 and over in research and clinical settings. © 2014 Public Health Association of Australia.

  15. Design of a Two-stage High-capacity Stirling Cryocooler Operating below 30K

    Science.gov (United States)

    Wang, Xiaotao; Dai, Wei; Zhu, Jian; Chen, Shuai; Li, Haibing; Luo, Ercang

    The high capacity cryocooler working below 30K can find many applications such as superconducting motors, superconducting cables and cryopump. Compared to the GM cryocooler, the Stirling cryocooler can achieve higher efficiency and more compact structure. Because of these obvious advantages, we have designed a two stage free piston Stirling cryocooler system, which is driven by a moving magnet linear compressor with an operating frequency of 40 Hz and a maximum 5 kW input electric power. The first stage of the cryocooler is designed to operate in the liquid nitrogen temperature and output a cooling power of 100 W. And the second stage is expected to simultaneously provide a cooling power of 50 W below the temperature of 30 K. In order to achieve the best system efficiency, a numerical model based on the thermoacoustic model was developed to optimize the system operating and structure parameters.

  16. Preparation and photocatalytic property of potassium niobate K6Nb10.8O30

    International Nuclear Information System (INIS)

    Zhang Gaoke; Zou Xi; Gong Jie; He Fangsheng; Zhang Hao; Zhang Qiang; Liu Ying; Yang Xia; Hu Bo

    2006-01-01

    The TB-type potassium niobate K 6 Nb 10.8 O 30 was synthesized by a simple solid-state reaction method. Scanning electron microscope (SEM) and X-ray diffractometer (XRD) were used to characterize the structure of the photocatalyst. The photocatalyst K 6 Nb 10.8 O 30 shows high photocatalytic activity to photodegrade acid red G under UV irradiation. The influences of catalyst dosage, initial concentration of acid red G on the photocatalytic reaction were investigated. The kinetics of photocatalytic degradation of acid red G follows the first order kinetics

  17. Certification of the Cu and Cd amount contents in artificial food digest using isotope dilution inductively coupled plasma mass spectrometry for Pilot Study 13 of the Comite Consultatif pour la Quantite de Matiere

    International Nuclear Information System (INIS)

    Vassileva, E.; Quetel, C.R.; Petrov, I.

    2003-01-01

    The Comite Consultatif pour la Quantite de Matiere (CCQM) launched the Pilot Study 13, an interlaboratory comparison between the metrological organizations worldwide on the determination of Ca, Cu and Cd in artificial food digests. These samples (available in 7% HNO 3 and with a salinity evaluated around 370 mg kg -1 , including approx. 30 mg Na kg -1 ) were prepared by gravimetrical mixing, and thus reference values traceable to the Kg for the three elements were available eventually. This paper describes the contribution of IRMM for the certification of the Cu and the Cd amount contents. The analytical protocol developed was based on isotope dilution associated to inductively coupled plasma mass spectrometry (ID-ICP-MS). The Cu measurements required 125-fold dilution of the initial sample solution. An interference of 23 Na 40 Ar + on 63 Cu + was identified but, since the ratio between both species was over 1000, it was successfully overcome by the calculation of a correction factor for its effect on the Cu amount content directly. Dilution of the sample was not possible for Cd only present at the low ng g -1 level. Up to 1% difference was observed on Cd isotope ratio results between measurements performed directly or after matrix separation. This is rarely shown. As similar results could be obtained either way after the necessary corrections, the direct measurements approach associated to a correction for mass discrimination effects using the CCQM-P13 sample itself (and the IUPAC table values as reference for the natural Cd isotopic composition) was preferred as it was the easiest. SI traceable values were obtained for Cu and Cd with less than 1 and 1.5% combined uncertainty, respectively (6 995±55 (k=2) nmol kg -1 and 45.53±0.64 (k=2) nmol kg -1 ). The excellent agreement between these results and the reference values (less than 0.6 and 0.08% difference) further validated the analytical protocols developed

  18. Comparison of predictions from internationally recognized assessment models for the transfer of selected radionuclides through terrestrial food chains

    International Nuclear Information System (INIS)

    Hoffman, F.O.; Bergstroem, U.; Gyllander, C.; Wilkens, A.B.

    1984-01-01

    Six internationally recognized terrestrial food-chain models developed in Sweden, the United States, the United Kingdom, the Federal Republic of Germany, and the International Atomic Energy Agency are compared. This comparison includes the data bases and predictions for the transfer of Co-60, Sr-90, I-131, and Cs-137 into milk, and leafy and nonleafy vegetables from a hypothetical 30-yr continuous rate of atmospheric deposition onto agricultural systems. Model predictions are compared against United Nations summaries of empirical relationships between atmospheric deposition and concentrations in food of Sr-90 and Cs-137. The results of statistical analyses of the effect of parameter uncertainties on model predictions are also included for Sr-90, Cs-137, and I-131. Discrepancies among model predictions vary between factors of 6 and 30. These results reflect differences in model assumptions rather than uncertainties in model parameters

  19. Report on EUROMET.RI(I)-K1 and EUROMET.RI(I)-K4 (EUROMET project no. 813): Comparison of air kerma and absorbed dose to water measurements of {sup 60}Co radiation beams for radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Csete, I. [National Office of Measures (OMH) - pilot laboratory and corresponding author (Hungary); Leiton, A.G. [Research Centre for Energy, Environment and Technology (CMRI-CIEMAT) (Spain); Sochor, V. [Czech Metrology Institute (CMI) (Czech Republic); Lapenas, A. [Latvian National Metrology Center (LNMC-RMTC) (Latvia); Grindborg, J.E. [Swedish Radiation Protection Authority (SSI) (Sweden); Jokelainen, I. [Radiation and Nuclear Safety Authority (STUK) (Finland); Bjerke, H. [Norwegian Radiation Protection Authority (NRPA) (Norway); Dobrovodsky, J. [Slovak Institute of Metrology (SMU) (Slovakia); Megzifene, A. [International Atomic Energy Agency, IAEA, Vienna (Austria); Hourdakis, C.J. [Hellenic Atomic Energy Committee (HAEC-HIRCL) (Greece); Ivanov, R. [National Centre of Metrology (NCM) (Bulgaria); Vekic, B. [Rudjer Boskovic Institute (IRB) (Croatia); Kokocinski, J. [Central Office of Measures (GUM) (Poland); Cardoso, J. [Institute for Nuclear Technology (ITN-LMRIR) (Portugal); Buermann, L. [Physikalisch Technische Bundesanstalt (PTB) (Germany); Tiefenboeck, W. [Bundesamt fur Eich und Vermesungswesen (BEV) (Austria); Stucki, G. [17 Bundesamt fur Metrologie (METAS) (Switzerland); Van Dijk, E. [NMi Van Swinden Laboratorium (NMi) (Netherlands); Toni, M.P. [ENEA-CR Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti (ENEA) (Italy); Minniti, R. [20 National Institute of Standards and Technology (NIST) (United States); McCaffrey, J.P. [National Research Council Canada (NRC) (Canada); Silva, C.N.M. [National Metrology Laboratory of Ionizing Radiation (LNMRI-IRD) (Brazil); Kharitonov, I. [D I Mendeleyev Institute for Metrology (VNIIM) (RU); Webb, D. [Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) (Australia); Saravi, M. [National Atomic Energy Commission (CNEA-CAE) (Argentina); Delaunay, F. [Laboratoire National Henri Becquerel (LNE-LNHB) (France)

    2010-06-15

    The results of an unprecedented international effort involving 26 countries are reported. The EUROMET.RI(I)-K1 and EUROMET.RI(I)-K4 key comparisons were conducted with the goal of supporting the relevant calibration and measurement capabilities (CMC) planned for publication by the participant laboratories. The measured quantities were the air kerma (K{sub air}) and the absorbed dose to water (Dw) in {sup 60}Co radiotherapy beams. The comparison was conducted by the pilot laboratory MKEH (Hungary), in a star-shaped arrangement from January 2005 to December 2008. The calibration coefficients of four transfer ionization chambers were measured using two electrometers. The largest deviation between any two calibration coefficients for the four chambers in terms of air kerma and absorbed dose to water was 2.7% and 3.3% respectively. An analysis of the participant uncertainty budgets enabled the calculation of degrees of equivalence (DoE), in terms of the deviations of the results and their associated uncertainties. As a result of this EUROMET project 813 comparison, the BIPM key comparison database (KCDB) will include eleven new Kair and fourteen new D{sub w} DoE values of European secondary standard dosimetry laboratories (SSDLs), and the KCDB will be updated with the new DoE values of the other participant laboratories. The pair-wise degrees of equivalence of participants were also calculated. In addition to assessing calibration techniques and uncertainty calculations of the participants, these comparisons enabled the experimental determinations of N{sub Dw}/N{sub Kair} ratios in the {sup 60}Co gamma radiation beam for the four radiotherapy transfer chambers. (authors)

  20. BILATERAL KEY COMPARISON SIM.T-K6.5 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM -30 °C TO +20 °C.

    Science.gov (United States)

    Meyer, C W; Solano, A

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range -30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET.

  1. A comparison of justice frameworks for international research.

    Science.gov (United States)

    Pratt, Bridget; Loff, Bebe

    2015-07-01

    Justice frameworks have been developed for international research that provide guidance on the selection of research targets, ancillary care, research capacity strengthening, and post-trial benefits. Yet there has been limited comparison of the different frameworks. This paper examines the underlying aims and theoretical bases of three such frameworks--the fair benefits framework, the human development approach and research for health justice--and considers how their aims impact their guidance on the aforementioned four ethical issues. It shows that the frameworks' underlying objectives vary across two dimensions. First, whether they seek to prevent harmful or exploitative international research or to promote international research with health benefits for low and middle-income countries. Second, whether they address justice at the micro level or the macro level. The fair benefits framework focuses on reforming contractual elements in individual international research collaborations to ensure fairness, whereas the other two frameworks aim to connect international research with the reduction of global health inequities. The paper then highlights where there is overlap between the frameworks' requirements and where differences in the strength and content of the obligations they identify arise as a result of their varying objectives and theoretical bases. In doing so, it does not offer a critical comparison of the frameworks but rather seeks to add clarity to current debates on justice and international research by showing how they are positioned relative to one another. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. The International Comparison of Value Added, Productivity and Purchasing Power Parities in Agriculture

    NARCIS (Netherlands)

    Maddison, Angus; Ooststroom, Harry van

    1993-01-01

    This study is part of the ICOP (International Comparison of Output and Productivity) project of the University of Groningen. It presents international comparisons of levels of value added, productivity and purchasing power parities (PPPs) in agriculture for 13 countries for 1975. An early version of

  3. How do american students measure up? Making sense of international comparisons.

    Science.gov (United States)

    Koretz, Daniel

    2009-01-01

    In response to frequent news media reports about how poorly American students fare compared with their peers abroad, Daniel Koretz takes a close look at what these comparisons say, and do not say, about the achievement of U.S. high school students. He stresses that the comparisons do not provide what many observers of education would like: unambiguous information about the effectiveness of American high schools compared with those in other nations. Koretz begins by describing the. two principal international student comparisons-the Trends in International Mathematics and Science Study (TIMSS) and the Program for International Student Assessment (PISA). Both assessments, he stresses, reflect the performance of students several years before they complete high school. PISA, which targets fifteen-year-old students, measures students' abilities to apply what they have learned in school to real-world problems. By contrast, TIMSS tests fourth and eighth graders. Unlike PISA, TIMSS follows the school curriculum closely. Because the findings of the two tests are sometimes inconsistent, Koretz stresses the importance of considering data from both sources. He cautions against comparing U.S. students with an "international average," which varies widely from survey to survey depending on which countries participate, and recommends instead comparing them with students in other nations that are similar to the United States or that are particularly high-achieving. Many observers, says Koretz, speculate that the lackluster average performance of American students in international comparisons arises because many, especially minority and low-income U.S. students, attend low-performing schools. But both TIMSS and PISA, he says, show that the performance of American students on the exams is not much more variable than that of students in countries that are socially more homogeneous or that have more equitable educational systems. Koretz emphasizes that the international comparisons

  4. High power cable with internal water cooling 400 kV

    Energy Technology Data Exchange (ETDEWEB)

    Rasquin, W; Harjes, B

    1982-08-01

    The project was planned for a duration of 4 years. Afterwards it has been extended over 6 years and finally stopped after 3 1/2 years. Therefore, of course results of field tests with an internally cooled 400 kV cable are not available. Nevertheless, this conductor cooled high power cable has been developed to such an extend, that this manufactured cable could withstand type tests according to IEC/VDE recommendations. Even by missing field tests it is obvious that a high power cable for 400 kV is available.

  5. KEY COMPARISON: Final report of comparison of the calibrations of hydrometers for liquid density determination between SIM laboratories: SIM.M.D-K4

    Science.gov (United States)

    Becerra, Luis Omar

    2009-01-01

    This SIM comparison on the calibration of high accuracy hydrometers was carried out within fourteen laboratories in the density range from 600 kg/m3 to 1300 kg/m3 in order to evaluate the degree of equivalence among participant laboratories. This key comparison anticipates the planned key comparison CCM.D-K4, and is intended to be linked with CCM.D-K4 when results are available. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  6. BILATERAL KEY COMPARISON SIM.T-K6.5 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM −30 °C TO +20 °C

    Science.gov (United States)

    Meyer, C.W.; Solano, A.

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range −30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET. PMID:28066029

  7. Evolution of plant virus movement proteins from the 30K superfamily and of their homologs integrated in plant genomes

    Energy Technology Data Exchange (ETDEWEB)

    Mushegian, Arcady R., E-mail: mushegian2@gmail.com [Division of Molecular and Cellular Biosciences, National Science Foundation, 4201 Wilson Boulevard, Arlington, VA 22230 (United States); Elena, Santiago F., E-mail: sfelena@ibmcp.upv.es [Instituto de Biología Molecular y Celular de Plantas, CSIC-UPV, 46022 València (Spain); The Santa Fe Institute, Santa Fe, NM 87501 (United States)

    2015-02-15

    Homologs of Tobacco mosaic virus 30K cell-to-cell movement protein are encoded by diverse plant viruses. Mechanisms of action and evolutionary origins of these proteins remain obscure. We expand the picture of conservation and evolution of the 30K proteins, producing sequence alignment of the 30K superfamily with the broadest phylogenetic coverage thus far and illuminating structural features of the core all-beta fold of these proteins. Integrated copies of pararetrovirus 30K movement genes are prevalent in euphyllophytes, with at least one copy intact in nearly every examined species, and mRNAs detected for most of them. Sequence analysis suggests repeated integrations, pseudogenizations, and positive selection in those provirus genes. An unannotated 30K-superfamily gene in Arabidopsis thaliana genome is likely expressed as a fusion with the At1g37113 transcript. This molecular background of endopararetrovirus gene products in plants may change our view of virus infection and pathogenesis, and perhaps of cellular homeostasis in the hosts. - Highlights: • Sequence region shared by plant virus “30K” movement proteins has an all-beta fold. • Most euphyllophyte genomes contain integrated copies of pararetroviruses. • These integrated virus genomes often include intact movement protein genes. • Molecular evidence suggests that these “30K” genes may be selected for function.

  8. Comparison in the calculation of committed effective dose using the ICRP 30 and ICRP 60 models for a repeated incorporation by inhalation of I-125; Comparacion en el calculo de la dosis efectiva comprometida usando los modelos del ICRP 30 y del ICRP 60 para una incorporacion repetida por inhalacion de I-125

    Energy Technology Data Exchange (ETDEWEB)

    Carreno P, A.L.; Cortes C, A. [CNSNS, Dr. Barragan 779, Col. Narvarte, Mexico D.F. (Mexico); Alonso V, G.; Serrano P, F. [IPN, Edificio de Fisica Avanzada Zacatenco, 07300 Mexico D.F. (Mexico)

    2005-07-01

    Presently work, a comparison in the calculation of committed effective dose using the models of the ICRP 30 and those of the ICRP 60 for the analysis of internal dose due to repeated incorporation of I-125 is shown. The estimations of incorporated activity are obtained starting from the proportionate data for an exercise of inter comparison, with which it should be determined the internal dose later on. For to estimate the initial activity incorporated by repeated dose was assumed that this it was given through of multiple individual incorporations which happened in the middle points of the monitoring periods. The results using the models of the ICRP 30 and of the ICRP 60 are compared and the causes of the differences are analyzed. (Author)

  9. APMP/TCRI key comparison report of measurement of air kerma for medium-energy x-rays (APMP.RI(I)-K3)

    International Nuclear Information System (INIS)

    Lee, J.H.; Hwang, W.S.; Kotler, L.H.; Webb, D.V.; Buermann, L.; Burns, D.T.; Takeyeddin, M.; Shaha, V.V.; Srimanoroth, S.; Meghzifene, A.; Hah, S.H.; Chun, K.J.; Kadni, T.B.; Takata, N.; Msimang, Z.

    2008-01-01

    The APMP/TCRI Dosimetry Working Group performed the APMP.RI(I)-K3 key comparison of measurement of air kerma for medium-energy x-rays (100 kV to 250 kV) between 2000 and 2003. In total, 11 institutes took part in the comparison, among which 8 were APMP member laboratories. Two commercial cavity ionization chambers were used as transfer instruments and circulated among the participants. All the participants established the 100 kV, 135 kV, 180 kV and 250 kV x-ray beam qualities equivalent to those of the BIPM. The results showed that the maximum difference between the participants and the BIPM in the medium-energy x-ray range, evaluated using the comparison data of the linking laboratories ARPANSA and PTB, is less than 1.4%. The degrees of equivalence between the participants are presented and this comparison confirms the calibration capabilities of the participating laboratories. (authors)

  10. APMP/TCRI key comparison report of measurement of air kerma for medium-energy x-rays (APMP.RI(I)-K3)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J.H.; Hwang, W.S. [Institute of Nuclear Energy Research, Longtan, Taiwan (China); Kotler, L.H.; Webb, D.V. [Australian Radiation Protection and Nuclear Safety Agency, Yallambie (Australia); Buermann, L. [Physikalisch Technische Bundesanstalt, Braunschweig (Germany); Burns, D.T. [Bureau International de Poids et Mesures, 92 - Sevres (France); Takeyeddin, M. [Atomic Energy Commission, Damascus (Syrian Arab Republic); Shaha, V.V. [Bhabha Atomic Research Centre, Mumbai (India); Srimanoroth, S. [Department of Medical Sciences, Nonthaburi (Thailand); Meghzifene, A. [International Atomic Energy Agency, Vienna (Austria); Hah, S.H.; Chun, K.J. [Korea Research Institute of Standards and Science, Yusong (Korea, Republic of); Kadni, T.B. [Malaysian Nuclear Agency, Kajang (Malaysia); Takata, N. [National Metrology Institute of Japan, Tsukuba (Japan); Msimang, Z. [National Metrology Institute of South Africa, Pretoria (South Africa)

    2008-10-15

    The APMP/TCRI Dosimetry Working Group performed the APMP.RI(I)-K3 key comparison of measurement of air kerma for medium-energy x-rays (100 kV to 250 kV) between 2000 and 2003. In total, 11 institutes took part in the comparison, among which 8 were APMP member laboratories. Two commercial cavity ionization chambers were used as transfer instruments and circulated among the participants. All the participants established the 100 kV, 135 kV, 180 kV and 250 kV x-ray beam qualities equivalent to those of the BIPM. The results showed that the maximum difference between the participants and the BIPM in the medium-energy x-ray range, evaluated using the comparison data of the linking laboratories ARPANSA and PTB, is less than 1.4%. The degrees of equivalence between the participants are presented and this comparison confirms the calibration capabilities of the participating laboratories. (authors)

  11. INTERNATIONAL COMPARISONS IN THE IMPROVEMENT OF EDUCATION

    Directory of Open Access Journals (Sweden)

    Hebert David G.

    2012-12-01

    Full Text Available Imperfections - such as inequality and inefficiency of learning - are perennial problems for education despite a diversity of foundations on which national systems are established, which range from the idealistic vision of fostering a utopian society to the utilitarian objective of producing skilled workers capable of engendering economic growth. Despite sharing many common conditions and fundamental values, educators rarely learn valuable lessons from the successes and failures of highly relevant initiatives in distant nations. This problem may be attributed to several factors, not the least of which includes the entrenchment of local traditions and ethnocentric assumptions, but surely the quality and relevance of international-comparative research - and the way its results are disseminated - are issues that must also be taken into careful consideration. What are the unique lessons to be learned from international comparisons, and what are the prospective risks for how such comparisons may be misinterpreted and misused in educational settings? How can international comparative research be made more relevant, with tangible applications that may be recognized and effectively used by school teachers? How can international comparative education meaningfully examine subjects beyond the reach of standardized testing, in such domains as the fostering of creativity, talent, and ethical sensibilities, for example? These themes will be presented through discussion of both research findings and anecdotes from the personal experience of working for universities on four continents. Specific topics will include the challenges of accounting for conceptual equivalency and representing cultural differences, sampling and generalizability, reconciling the diverging aims of economic, anthropological, sociological, and psychological research, as well as grappling with the ambivalent discourse of globalization, multiculturalism, post-colonialism, and other social

  12. Time-resolved 3D pulmonary perfusion MRI: comparison of different k-space acquisition strategies at 1.5 and 3 T.

    Science.gov (United States)

    Attenberger, Ulrike I; Ingrisch, Michael; Dietrich, Olaf; Herrmann, Karin; Nikolaou, Konstantin; Reiser, Maximilian F; Schönberg, Stefan O; Fink, Christian

    2009-09-01

    Time-resolved pulmonary perfusion MRI requires both high temporal and spatial resolution, which can be achieved by using several nonconventional k-space acquisition techniques. The aim of this study is to compare the image quality of time-resolved 3D pulmonary perfusion MRI with different k-space acquisition techniques in healthy volunteers at 1.5 and 3 T. Ten healthy volunteers underwent contrast-enhanced time-resolved 3D pulmonary MRI on 1.5 and 3 T using the following k-space acquisition techniques: (a) generalized autocalibrating partial parallel acquisition (GRAPPA) with an internal acquisition of reference lines (IRS), (b) GRAPPA with a single "external" acquisition of reference lines (ERS) before the measurement, and (c) a combination of GRAPPA with an internal acquisition of reference lines and view sharing (VS). The spatial resolution was kept constant at both field strengths to exclusively evaluate the influences of the temporal resolution achieved with the different k-space sampling techniques on image quality. The temporal resolutions were 2.11 seconds IRS, 1.31 seconds ERS, and 1.07 VS at 1.5 T and 2.04 seconds IRS, 1.30 seconds ERS, and 1.19 seconds VS at 3 T.Image quality was rated by 2 independent radiologists with regard to signal intensity, perfusion homogeneity, artifacts (eg, wrap around, noise), and visualization of pulmonary vessels using a 3 point scale (1 = nondiagnostic, 2 = moderate, 3 = good). Furthermore, the signal-to-noise ratio in the lungs was assessed. At 1.5 T the lowest image quality (sum score: 154) was observed for the ERS technique and the highest quality for the VS technique (sum score: 201). In contrast, at 3 T images acquired with VS were hampered by strong artifacts and image quality was rated significantly inferior (sum score: 137) compared with IRS (sum score: 180) and ERS (sum score: 174). Comparing 1.5 and 3 T, in particular the overall rating of the IRS technique (sum score: 180) was very similar at both field

  13. KEY COMPARISON: Final report on bilateral comparison CCEM.RF-K9.1: Thermal noise standards at 12.4 GHz, 13.5 GHz, 15 GHz and 17.5 GHz

    Science.gov (United States)

    Allal, Djamel

    2009-01-01

    A bilateral comparison subsequent to key comparison CCEM.RF-K9 was decided between VNIIFTRI and PTB. It was registered into the BIPM KCDB under the identifier CCEM.RF-K9.1. The results of this comparison were gathered by the pilot laboratory of comparison CCEM.RF-K9, the LNE, and a very good agreement was found between the two participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  14. Lovkommentar i Karnovs Lovsamling af Lovbekendtgørelse 2014-11-21 nr. 1224 International købelov (CISG: Convention on Contracts for the International Sale of Goods)

    DEFF Research Database (Denmark)

    Lookofsky, Joseph

    2018-01-01

    CISG er en international konvention, som indeholder regler om købsaftaler i international handel. CISG regulerer blandt andet, hvornår en international købsaftale er indgået, købers og sælgers rettigheder, forpligtelser samt misligholdelsesbeføjelser mm. CISG finder anvendelse, dels når såvel...... sælgers som købers hjemland har tiltrådt konventionen, dels når international privatrets regler fører til anvendelsen af en kontraherende stats ret. CISG trådte i kraft 1988-01-01. Den danske ratifikation skete 1989-02-04. CISG er ratificeret af godt 85 andre lande (2017). Som et led i den danske...

  15. Two Novel 30K Proteins Overexpressed in Baculovirus System and Their Antiapoptotic Effect in Insect and Mammalian Cells

    Directory of Open Access Journals (Sweden)

    Wei Yu

    2013-01-01

    Full Text Available The 30K family of proteins is important in energy metabolism and may play a role in inhibiting cellular apoptosis in silkworms (Bombyx mori. Several 30K-family proteins have been identified. In this study, two new silkworm genes, referred to as Slp (NM 001126256 and Lsp-t (NM 001043443, were analyzed by a bioinformatics approach according to the sequences of 30K proteins previously reported in the silkworm. Both Slp and Lsp-t shared more than 41% amino acid sequence homology with the reported 30K proteins and displayed a conserved domain consistent with that of lipoprotein-11. Additionally, the cDNA sequences of both Slp and Lsp-t were obtained from the fat bodies of silkworm larvae by reverse transcription polymerase chain reaction. Both genes were expressed in BmN cells using the Bac-to-Bac system. Purified Slp and Lsp-t were added to cultured BmN and human umbilical vein endothelial cells (HUVEC that were treated with H2O2. Both Slp and Lsp-t significantly enhanced the viability and suppressed DNA fragmentation in H2O2 treated BmN and HUVEC cells. This study suggested that Slp and Lsp-t exhibit similar biological activities as their known 30K-protein counterparts and mediate an inhibitory effect against H2O2-induced apoptosis.

  16. Technical Support Document: Development of the Advanced Energy Design Guide for K-12 Schools--30% Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Pless, S.; Torcellini, P.; Long, N.

    2007-09-01

    This Technical Support Document describes the process and methodology for the development of the Advanced Energy Design Guide for K-12 School Buildings (K-12 AEDG), a design guidance document intended to provide recommendations for achieving 30% energy savings in K-12 Schools over levels contained in ANSI/ASHRAE/IESNA Standard 90.1-1999, Energy Standard for Buildings Except Low-Rise Residential Buildings. The 30% energy savings target is the first step toward achieving net-zero energy schools; schools that, on an annual basis, draw from outside sources less or equal energy than they generate on site from renewable energy sources.

  17. Design and simulation of a 30 kV, 60 kW electron optical column for melting applications

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Sachin; Kandaswamy, E.; Bapat, A.V., E-mail: saching@barc.gov.in [Bhabha Atomic Research Centre, Mumbai (India)

    2014-07-01

    Electron beam offers unique advantages as a heat source for melting of refractory metals. It provides contamination free homogeneous melting with precise heat control on the melt target. This paper reports the complete electron optics design procedure for a 30 kV, 60 kW melting gun. The design objective of the electron optical column is to obtain the required power density on the target (10{sup 3}-10{sup 4} W/cm{sup 2}) using electrostatic and electromagnetic lenses. The design constrains are to minimize the high voltage discharges in the gun and beam losses in the beam transport. The challenging task of reducing the electrical discharges in the gun during high power melting with the help of twin electromagnetic lenses is presented in the paper. (author)

  18. A Comparison of Internal Dispositions and Career Trajectories after Collaborative versus Apprenticed Research Experiences for Undergraduates.

    Science.gov (United States)

    Frantz, Kyle J; Demetrikopoulos, Melissa K; Britner, Shari L; Carruth, Laura L; Williams, Brian A; Pecore, John L; DeHaan, Robert L; Goode, Christopher T

    2017-01-01

    Undergraduate research experiences confer benefits on students bound for science, technology, engineering, and mathematics (STEM) careers, but the low number of research professionals available to serve as mentors often limits access to research. Within the context of our summer research program (BRAIN), we tested the hypothesis that a team-based collaborative learning model (CLM) produces student outcomes at least as positive as a traditional apprenticeship model (AM). Through stratified, random assignment to conditions, CLM students were designated to work together in a teaching laboratory to conduct research according to a defined curriculum led by several instructors, whereas AM students were paired with mentors in active research groups. We used pre-, mid-, and postprogram surveys to measure internal dispositions reported to predict progress toward STEM careers, such as scientific research self-efficacy, science identity, science anxiety, and commitment to a science career. We are also tracking long-term retention in science-related career paths. For both short- and longer-term outcomes, the two program formats produced similar benefits, supporting our hypothesis that the CLM provides positive outcomes while conserving resources, such as faculty mentors. We discuss this method in comparison with course-based undergraduate research and recommend its expansion to institutional settings in which mentor resources are scarce. © 2017 K. J. Frantz et al. CBE—Life Sciences Education © 2017 The American Society for Cell Biology. This article is distributed by The American Society for Cell Biology under license from the author(s). It is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  19. The Generalized Internal/External Frame of Reference Model: An Extension to Dimensional Comparison Theory

    Science.gov (United States)

    Möller, Jens; Müller-Kalthoff, Hanno; Helm, Friederike; Nagy, Nicole; Marsh, Herb W.

    2016-01-01

    The dimensional comparison theory (DCT) focuses on the effects of internal, dimensional comparisons (e.g., "How good am I in math compared to English?") on academic self-concepts with widespread consequences for students' self-evaluation, motivation, and behavioral choices. DCT is based on the internal/external frame of reference model…

  20. Sample environment for neutron scattering measurements of internal stresses in engineering materials in the temperature range of 6 K to 300 K.

    Science.gov (United States)

    Kirichek, O; Timms, J D; Kelleher, J F; Down, R B E; Offer, C D; Kabra, S; Zhang, S Y

    2017-02-01

    Internal stresses in materials have a considerable effect on material properties including strength, fracture toughness, and fatigue resistance. The ENGIN-X beamline is an engineering science facility at ISIS optimized for the measurement of strain and stress using the atomic lattice planes as a strain gauge. Nowadays, the rapidly rising interest in the mechanical properties of engineering materials at low temperatures has been stimulated by the dynamic development of the cryogenic industry and the advanced applications of the superconductor technology. Here we present the design and discuss the test results of a new cryogenic sample environment system for neutron scattering measurements of internal stresses in engineering materials under a load of up to 100 kN and in the temperature range of 6 K to 300 K. Complete cooling of the system starting from the room temperature down to the base temperature takes around 90 min. Understanding of internal stresses in engineering materials at cryogenic temperatures is vital for the modelling and designing of cutting-edge superconducting magnets and other superconductor based applications.

  1. Final report on EUROMET key comparison EUROMET.M.D-K2 (EUROMET 627) "Comparison of density determinations of liquid samples"

    Science.gov (United States)

    Bettin, Horst; Heinonen, Martti; Gosset, André; Zelenka, Zoltán; Lorefice, Salvatore; Hellerud, Kristen; Durlik, Hanna; Jordaan, Werner; Field, Ireen

    2016-01-01

    The results of the key comparison EUROMET 627 (EUROMET.M.D-K2) are presented. This project covered the density measurements of three liquids: dodecane, water and an oil of high viscosity measured at 15 °C, 20 °C and 40 °C. Seven European metrology laboratories and the South African laboratory CSIR-NML (now: NMISA) measured the densities at atmospheric pressure by hydrostatic weighing of solid density standards between 04 October 2001 and 18 December 2001. The stability and homogeneity of the liquids were investigated by the pilot laboratory PTB. The results generally show good agreement among the participants. Only for the simple Mohr-Westphal balances do the uncertainties seem to be underestimated by the laboratories. Furthermore, the measurement of high-viscosity oil was difficult for some laboratories. Nevertheless, the five laboratories PTB/DE, BNM/FR (now: LNE/FR), OMH/HU (now: MKEH/HU), IMGC/IT (now: INRIM/IT) and GUM/PL agree with each other for stated uncertainties of 0.05 kg/m3 or less. This satisfies the current needs of customers who wish to calibrate or check liquid density measuring instruments such as oscillation-type density meters. No reference values were calculated since the subsequent CCM key comparison CCM.D-K2 had a different scope and the EUROMET 627 comparison was soon superseded by the EURAMET 1019 (EURAMET.M.D-K2) comparison. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Partial molar volumes of organic solutes in water. XXVIII. Three aliphatic poly(ethylene glycols) at temperatures T = 298 K–573 K and pressures up to 30 MPa

    International Nuclear Information System (INIS)

    Cibulka, Ivan

    2017-01-01

    Highlights: • Standard molar volumes of three poly(ethylene glycols) in water are presented. • Data were obtained in the range T from (298 to 573) K and p up to 30 MPa. • Data are analyzed and compared with those of similar solutes. - Abstract: Densities of dilute aqueous solutions of three poly(ethylene glycols): 3-oxapentane-1,5-diol (diethylene glycol), 3,6-dioxaoctane-1,8-diol (triethylene glycol), and 3,5,9-trioxaundecane-1,11-diol (tetraethylene glycol) measured in the temperature range from (298 to 573) K and at pressures up to 30 MPa using an automated flow vibrating-tube densimeter are reported. Standard molar volumes were evaluated from the measured data. Present data complement both the previous measurements performed at atmospheric pressure in the temperature range from (278 to 343) K and the data already available for the first member of the homologous series (ethylene glycol). A comparison with data previously measured for the homologous series of linear aliphatic polyethers (poly(ethylene glycol) dimethyl ethers, glymes), diethylene glycol monomethyl ether (3,6-dioxaheptan-1-ol), and selected alkane-α,ω-diols is presented.

  3. Structures of three different neutral polysaccharides of Acinetobacter baumannii, NIPH190, NIPH201, and NIPH615, assigned to K30, K45, and K48 capsule types, respectively, based on capsule biosynthesis gene clusters.

    Science.gov (United States)

    Shashkov, Alexander S; Kenyon, Johanna J; Arbatsky, Nikolay P; Shneider, Mikhail M; Popova, Anastasiya V; Miroshnikov, Konstantin A; Volozhantsev, Nikolay V; Knirel, Yuriy A

    2015-11-19

    Neutral capsular polysaccharides (CPSs) were isolated from Acinetobacter baumannii NIPH190, NIPH201, and NIPH615. The CPSs were found to contain common monosaccharides only and to be branched with a side-chain 1→3-linked β-d-glucopyranose residue. Structures of the oligosaccharide repeat units (K units) of the CPSs were elucidated by 1D and 2D (1)H and (13)C NMR spectroscopy. Novel CPS biosynthesis gene clusters, designated KL30, KL45, and KL48, were found at the K locus in the genome sequences of NIPH190, NIPH201, and NIPH615, respectively. The genetic content of each gene cluster correlated with the structure of the CPS unit established, and therefore, the capsular types of the strains studied were designated as K30, K45, and K48, respectively. The initiating sugar of each K unit was predicted, and glycosyltransferases encoded by each gene cluster were assigned to the formation of the linkages between sugars in the corresponding K unit. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Lessons learnt from participation in international inter-comparison exercise for environmental radioactivity measurement

    International Nuclear Information System (INIS)

    Jha, S.K.; Pulhani, Vandana; Sartandel, Sangeeta

    2016-06-01

    Environmental Radioactivity Measurement Section of Health Physics Division is regularly carrying out surveillance of the radioactivity concentration in the environment. The laboratory participates in the inter-comparison exercises conducted by various international agencies for quality assurance and quality control of analytical estimations. This report summarizes the results of the analysis of radioactivity in environmental matrices of the inter-comparison exercises. The participation in inter-comparison exercises has demonstrated competence in radionuclide identification and estimations, equivalence with the results of other participating laboratories, validated adopted analytical methods, introduced traceability to measurement etc. at national and international level. (author)

  5. International Semiotics: Item Difficulty and the Complexity of Science Item Illustrations in the PISA-2009 International Test Comparison

    Science.gov (United States)

    Solano-Flores, Guillermo; Wang, Chao; Shade, Chelsey

    2016-01-01

    We examined multimodality (the representation of information in multiple semiotic modes) in the context of international test comparisons. Using Program of International Student Assessment (PISA)-2009 data, we examined the correlation of the difficulty of science items and the complexity of their illustrations. We observed statistically…

  6. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, March to April 2011 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    Science.gov (United States)

    Power, O.; Solve, S.; Chayramy, R.; Stock, M.

    2011-01-01

    As a part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from March to April 2011. Two BIPM Zener diode-based travelling standards (Fluke 732B) were transported by freight to NSAI-NML. At NSAI-NML, the 10 V output EMF of each travelling standard was measured by direct comparison with a group of characterized Zener diode-based electronic voltage standards. At the BIPM, the travelling standards were calibrated before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages on internal temperature and ambient pressure. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated expanded uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  7. International comparisons in critical care: a necessity and challenge.

    Science.gov (United States)

    Wunsch, Hannah; Rowan, Kathryn M; Angus, Derek C

    2007-12-01

    Understanding variation in critical care resources, and delivery of care between countries will allow for improved disaster planning, evaluation of research findings, and assessment of the utility of critical care itself. This review describes the available data for international comparisons and the many factors that need to be addressed for an appropriate interpretation of results. Recent studies on subgroups of critical care patients include data from many different countries. These new studies provide important information on the overall incidence of these disease states, but most of these international studies do not take into account the critical care resources of the countries being discussed. For an appropriate interpretation of findings the relevant baseline critical care resources, prevalence of diseases, and cultural practices, need to be quantified. The existence of these other factors prevents the use of a severity of illness scoring system alone to account for differences between countries. Many recent critical care studies include data from multiple countries. With continued movement towards international studies, and improvements in data collection systems, comparisons between countries are becoming easier. These findings need to be interpreted in the context of all the relevant country information.

  8. Results of an international comparison for the determination of radionuclide activity in bilberry material

    International Nuclear Information System (INIS)

    Wätjen, U.; Altzitzoglou, T.; Ceccatelli, A.; Dikmen, H.; Emteborg, H.; Ferreux, L.; Frechou, C.; La Rosa, J.; Luca, A.; Moreno, Y.; Oropesa, P.; Pierre, S.; Schmiedel, M.

    2012-01-01

    Radioactivity found in wild food products has assumed greater importance when assessing the total exposure of the population. For this reason, IRMM has been developing a reference material for the activity concentration of three radionuclides in bilberry samples. In order to characterise this new material, a CCRI(II) supplementary comparison was organised. The difficulties encountered in this comparison are discussed, in particular the efficiency calibration for volume sources of gamma-ray emitters, and comparison reference values for 137 Cs and 40 K are calculated. - Highlights: ► CCRI(II) supplementary comparison for Cs-137 and K-40 in bilberry matrix completed. ► Fundamentally different methods used to establish link to SI traceable standards and SIR. ► Variation of results higher than in CCRI(II) key comparisons. ► Comparison reference values will be robust property values of IRMM reference material. ► Certified reference material for radioactivity in food developed.

  9. Thermal properties of Permian Basin evaporites to 493 K and 30 MPa confining pressure

    International Nuclear Information System (INIS)

    Durham, W.B.; Heard, H.C.; Boro, C.O.; Keller, K.T.; Ralph, W.E.; Trimmer, D.A.

    1987-01-01

    Laboratory measurements have been made of the thermal conductivity and diffusivity of four rock salts, two anhydrites, and two dolomites bordering the Cycle 4 and Cycle 5 bedded salt formations in the Permian Basin in Deaf Smith County, Texas. Measurement conditions ranged from 303 to 473 K in temperature, and 0.1 to 31.0 MPa in hydrostatic confining pressure. Within the +-5% measurement resolution neither conductivity nor diffusivity showed a dependence upon pressure in any of the rocks. Conductivity and diffusivity in all rocks had a negative temperature dependence. For the two Cycle 4 salt samples, conductivity over the temperature range explored fell from 5.5 to 3.75 W/m.K, and diffusivity fell from about 2.7 to 1.7 x 10 -6 m 2 /s. One of the Cycle 5 salts was a single crystal which had anomalous results, but the other had a low conductivity, about 3.4 W/m.K, with very weak temperature dependence, and a high diffusivity, 3.8 to 2.5 x 10 -6 m 2 /s over the temperature range. In the nonsalts, conductivity and diffusivity decreased 10 to 20% over the temperature range explored, which was 308 -6 m 2 /s for the anhydrites and 1.4 x 10 -6 m 2 /s for both the dolomites. The coefficient of thermal linear expansion was measured for the Cycle 5 salt and nonsalts over 308 -6 K -1 at P = 3.0 MPa to 4 x 10 -6 K -1 at P = 30 MPa for both nonsalt rocks. In anhydrite, it decreased with increasing temperature at a rate of roughly 5 x 10 -8 K -2 at all pressures. In dolomite, the coefficient increased at roughly the same rate. Expansion of the salt ranged from 33 to 38 x 10 -6 K -1 and was independent of pressure and temperature

  10. Activity measurements of the radionuclide {sup 57}Co for the NMIJ, Japan and the LNE-LNHB, France in the ongoing comparison BIPM.RI(II)-K1.Co-57

    Energy Technology Data Exchange (ETDEWEB)

    Michotte, C.; Ratel, G.; Courte, S. [Bureau International des Poids et Mesures (BIPM), 92 - Sevres (France); Hino, Y.; Yunoki, A. [National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki (Japan); Bobin, C.; Moune, M. [CEA Saclay, Laboratoire National de Metrologie et d' Essais, Laboratoire National Henri Becquerel (LNE-LNHB), 91 - Gif-sur-Yvette (France)

    2009-04-15

    In 2006 and 2007, the National Metrology Institute of Japan (NMIJ) and the Laboratoire national de metrologie et d'essais-Laboratoire national Henri Becquerel (LNE-LNHB) submitted samples of known activity of {sup 57}Co to the International Reference System (SIR). The values of the activity submitted were about 1.7 MBq and 3.7 MBq respectively. The new key comparison results have replaced the previous results for Japan and France. These new results have enabled a re-evaluation of the key comparison reference value. The matrix of degrees of equivalence in the key comparison database that now contains twelve results, identifier BIPM.RI(II)-K1.Co-57, has been updated with the new results. (authors)

  11. Bilateral comparison of 1 Ω standards (ongoing BIPM key comparison BIPM.EM-K13.a) between the NSAI-NML (Ireland) and the BIPM

    Science.gov (United States)

    Goebel, R.; Power, O.; Fletcher, N.; Stock, M.

    2012-01-01

    This report describes the results obtained from a NML(Ireland)-BIPM bilateral comparison of 1 Ω resistance standards in 2010. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.a. Two BIPM 1 Ω travelling standards of CSIRO type were calibrated first at the BIPM, then at the NMLI and again at the BIPM after their return. The stability of the transfer standard was such that the uncertainty associated with the transfer was significantly smaller than the uncertainty arising from the calibrations. The mean difference between the NMLI and the BIPM calibrations was found to be just within the expanded uncertainty (k = 2) of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  12. 30 kV/10 mA solid state anode modulator for gyrotron plasma heating: design issues and results

    International Nuclear Information System (INIS)

    Fasel, D.; Lucia, C.; Ganuza, D.; Doyharzabal, I.

    2001-01-01

    Three 30 kV/10 mA solid state pulsed modulators have been delivered to the CRPP in Lausanne, by the company JEMA. Each modulator supplies the anode grid of a triode type gyrotron, used for heating purpose at the third harmonic in the TCV Tokamak. The main parameters of the final design are: the use of solid state technology, a floating output referred to the -80 kV of the gyrotron cathode potential, an output voltage range of -5 to 30 kV, 1 kHz square and sinusoidal modulation, fast switching off to -5 kV (10 μs) and pulsed operation (duty cycle of 1%). After studying and testing a solution based on regulated Mosfet transistors in series, a more stable alternative has been adopted. The final topology consists of a rectifier fed from an insulated 230 V input, a chopper, two inverter steps (for +30 and -5 kV) supplying two diode rectifiers bridges through HV transformers with two switches which commute the load to the positive or negative voltage, connected in series. This article presents the most significant aspects of the design, with special emphasis on the control principle. The final results will be presented in the context of normal operation, supplying a triode gyrotron

  13. Reconciliation of international administrative coding systems for comparison of colorectal surgery outcome.

    Science.gov (United States)

    Munasinghe, A; Chang, D; Mamidanna, R; Middleton, S; Joy, M; Penninckx, F; Darzi, A; Livingston, E; Faiz, O

    2014-07-01

    Significant variation in colorectal surgery outcomes exists between different countries. Better understanding of the sources of variable outcomes using administrative data requires alignment of differing clinical coding systems. We aimed to map similar diagnoses and procedures across administrative coding systems used in different countries. Administrative data were collected in a central database as part of the Global Comparators (GC) Project. In order to unify these data, a systematic translation of diagnostic and procedural codes was undertaken. Codes for colorectal diagnoses, resections, operative complications and reoperative interventions were mapped across the respective national healthcare administrative coding systems. Discharge data from January 2006 to June 2011 for patients who had undergone colorectal surgical resections were analysed to generate risk-adjusted models for mortality, length of stay, readmissions and reoperations. In all, 52 544 case records were collated from 31 institutions in five countries. Mapping of all the coding systems was achieved so that diagnosis and procedures from the participant countries could be compared. Using the aligned coding systems to develop risk-adjusted models, the 30-day mortality rate for colorectal surgery was 3.95% (95% CI 0.86-7.54), the 30-day readmission rate was 11.05% (5.67-17.61), the 28-day reoperation rate was 6.13% (3.68-9.66) and the mean length of stay was 14 (7.65-46.76) days. The linkage of international hospital administrative data that we developed enabled comparison of documented surgical outcomes between countries. This methodology may facilitate international benchmarking. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  14. Comparison of measurement- and proxy-based Vs30 values in California

    Science.gov (United States)

    Yong, Alan K.

    2016-01-01

    This study was prompted by the recent availability of a significant amount of openly accessible measured VS30 values and the desire to investigate the trend of using proxy-based models to predict VS30 in the absence of measurements. Comparisons between measured and model-based values were performed. The measured data included 503 VS30 values collected from various projects for 482 seismographic station sites in California. Six proxy-based models—employing geologic mapping, topographic slope, and terrain classification—were also considered. Included was a new terrain class model based on the Yong et al. (2012) approach but recalibrated with updated measured VS30 values. Using the measured VS30 data as the metric for performance, the predictive capabilities of the six models were determined to be statistically indistinguishable. This study also found three models that tend to underpredict VS30 at lower velocities (NEHRP Site Classes D–E) and overpredict at higher velocities (Site Classes B–C).

  15. KEY COMPARISON: CCEM.RF-K18.CL (GT-RF/00-1): Noise in 50 Ω coaxial line at frequencies up to 1 GHz

    Science.gov (United States)

    Eiø, Christopher; Adamson, David; Randa, James; Allal, Djamel; Uzdin, Rinadij

    2006-01-01

    A measurement comparison of noise temperature has been carried out between four national metrology laboratories in coaxial line at 30 MHz, 60 MHz and 1 GHz. The identification of this intercomparison is CCEM.RF-K18.CL. Two noise sources have been measured. The following four national laboratories participated in this intercomparison: NPL (United Kingdom), NIST (United States of America), BNM-LNE (France) and VNIIFTRI (Russia). The National Physical Laboratory (UK) acted as the pilot laboratory for the comparison. It can be seen that there is generally good agreement between the laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  16. An international comparison of grade 6 students' understanding of the equal sign.

    Science.gov (United States)

    Capraro, Robert M; Capraro, Mary Margaret; Yetkiner, Z Ebrar; Ozel, Serkan; Kim, Hae Gyu; Küçük, Ali Riza

    2010-02-01

    This study extends the scope of international comparisons examining students' conceptions of the equal sign. Specifically, Korean (n = 193) and Turkish (n = 334) Grade 6 students were examined to assess whether their conceptions and responses were similar to prior findings published for Chinese and U.S. students and to hypothesize relationships about problem types and conceptual understanding of the equal sign. About 59.6% of the Korean participants correctly answered all items providing conceptually accurate solutions, as compared to 28.4% of the Turkish sample. Comparison with previous studies in China and the USA indicated that the Chinese sample outperformed those from other nations, followed by Korea, Turkey, and the USA. In large-scale international studies such as Trends in International Mathematics and Science (TIMSS) and the Programme for International Student Assessment (PISA), students from China and Korea have been among the high achievers.

  17. A measurement method for determination of dc internal resistance of batteries and supercapacitors

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Shuhong; Wu, Feng [Department of Materials Science, Beijing Science and Technology University, Beijing 100081 (China); Yang, Liuxiang; Gao, Lijun [Department of Chemistry, NanChang University, JiangXi 330031 (China); Burke, Andrew F. [Institute of Transportation, University of California, Davis, CA 95616 (United States)

    2010-02-15

    Internal resistance is an importance parameter determining the power performance of a battery or supercapacitor. An 8.5 Ah Li-ion battery and a 350 F supercapacitor were tested as examples to validate the measurement method of dc internal resistance. Voltage data were taken at 10 ms, 2 s and 30 s after the current interruption or pulse. The ac resistances at 1 kHz of the battery and supercapacitor were also measured for comparison with the dc values. Based on these tests, it is proposed that the dc internal resistance of the battery and supercapacitor be obtained from {delta}V/{delta}I where the {delta}V is the voltage change after the current interruption, and {delta}I means current change from I to 0. When the voltage change at 10 ms or less is selected, the resistance corresponds to the Ohmic resistance of the device. (author)

  18. Update of the BIPM comparison BIPM.RI(2)-K1.Cr-51 to include new activity measurements for the LNE-LNHB (France) and the pilot study result of the LNMRI (Brazil)

    Energy Technology Data Exchange (ETDEWEB)

    Ratel, G.; Michotte, C.; Kryeziu, D. [Bureau International des Poids et Mesures (BIPM), 92 - Sevres (France); Moune, M. [CEA Saclay, Laboratoire National de Metrologie et d' Essais, Laboratoire National Henri Becquerel (LNE-LNHB), 91 - Gif-sur-Yvette (France); Iwahara, A. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI), Rio de Janeiro (Brazil)

    2009-04-15

    In 2006, two national metrology institutes (NMI) submitted samples of known activity of {sup 51}Cr solution to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). Consequently, 28 samples have been submitted since 1977, from nine NMI and three other laboratories. The activities ranged from about 3 MBq to 90 MBq. The key comparison reference value (KCRV) has been updated and the degrees of equivalence between each equivalent activity measured in the SIR and the KCRV have been calculated. The results are given in the form of a matrix for eight laboratories to which the APMP.RI(II)-K2.Cr-51 results have been added. A graphical presentation is also given. (authors)

  19. K-scrambling in a near-symmetric top molecule containing an excited noncoaxial internal rotor

    International Nuclear Information System (INIS)

    Ortigoso, Juan; Hougen, Jon T.

    2000-01-01

    Classical trajectories on rotational energy surfaces and coherent-state quantum projections have been used to study an asymmetric-top molecule containing a freely rotating internal symmetric top whose symmetry axis is not coincident with a principal axis of the molecule. Stationary points on the rotational energy surface, which strongly influence the trajectories, increase in number from two to four to six as J/n increases from zero to infinity (where J is the total and n is the free-internal-rotor angular momentum). For some J/n values trajectories can arise that sample a large fraction of K values (where K is the z-axis projection of J), corresponding in quantum wave functions to extensive K mixing in the symmetric-top basis set |J,K>. When such mixing cannot be made small for any choice of z axis, we call it K scrambling. For typical values of the torsion-rotation coupling parameter ρ, rotational eigenfunctions for a given J and torsional state turn out to be quite different from eigenfunctions for the same J in some other torsional state. Nonzero rotational overlap integrals are then distributed among many rotational functions for each (n,n ' ) pair, which may, in turn, contribute to internal rotation enhancement of intramolecular vibrational energy redistribution. We have also examined near-free-rotor levels of our test molecule acetaldehyde, which arise for excitation of ten or more quanta of methyl group torsion, and find that barrier effects do not change the qualitative picture obtained from the free-rotor treatment. (c) 2000 American Institute of Physics

  20. Fluxes of Ca2+ and K+ are required for the listeriolysin O-dependent internalization pathway of Listeria monocytogenes.

    Science.gov (United States)

    Vadia, Stephen; Seveau, Stephanie

    2014-03-01

    Listeria monocytogenes is responsible for the life-threatening food-borne disease listeriosis. This disease mainly affects elderly and immunocompromised individuals, causing bacteremia and meningoencephalitis. In pregnant women, L. monocytogenes infection leads to abortion and severe infection of the fetus or newborn. The L. monocytogenes intracellular life cycle is critical for pathogenesis. Previous studies have established that the major virulence factor of L. monocytogenes, the pore-forming toxin listeriolysin O (LLO), is sufficient to induce L. monocytogenes internalization into human epithelial cell lines. This internalization pathway strictly requires the formation of LLO pores in the plasma membrane and can be stimulated by the heterologous pore-forming toxin pneumolysin, suggesting that LLO acts nonspecifically by forming transmembrane pores. The present work tested the hypothesis that Ca2+ and K+ fluxes subsequent to perforation by LLO control L. monocytogenes internalization. We report that L. monocytogenes perforates the host cell plasma membrane in an LLO-dependent fashion at the early stage of invasion. In response to perforation, host cells undergo Ca2+ -dependent but K+ -independent resealing of their plasma membrane. In contrast to the plasma membrane resealing process, LLO-induced L. monocytogenes internalization requires both Ca2+ and K+ fluxes. Further linking ion fluxes to bacterial internalization, treating cells with a combination of Ca2+ and K+ ionophores but not with individual ionophores is sufficient to induce efficient internalization of large cargoes, such as 1-μm polystyrene beads and bacteria. We propose that LLO-induced L. monocytogenes internalization requires a Ca2+ - and K+ -dependent internalization pathway that is mechanistically distinct from the process of plasma membrane resealing.

  1. International comparison of 50/60 Hz power (1996-1999)

    CSIR Research Space (South Africa)

    Oldham, N

    2001-04-01

    Full Text Available An international comparison of 50/60 Hz power is described. The travelling standard was an electronic power transducer that was tested at 120 V, 5 A, 53 Hz, at five power factors (1.0, 0.5, and 0.0). Fifteen National Metrology Institutes (NMIs) from...

  2. [Pitfalls in international comparisons of health data and indices].

    Science.gov (United States)

    Rotstein, Z; Shani, M

    1991-05-01

    Comparison of published data and health indices from different countries with different health systems is subject to many pitfalls. Comparison of national expenditure for health care based on purchasing power of the currency may be misleading if the purchasing power of the health services is ignored. Comparisons may also be misleading if they ignore national geographic and demographic structures. Government and health authorities often quote different sets of data and use different terminology and definitions. This article stresses the disparity in the definition of medical manpower and points out differences relating to ratios of manpower to population and to per capita spending. Also addressed is the importance of the qualitative and value aspects of health systems not usually involved in comparison of international health indices. In conclusion, safety measures and precautions such as choosing the right index for the right purpose, adjustment of indices to the purchasing power parity of health, demographics, etc., should be used when conducting health care analyses.

  3. Soluble CD30 in normotensive pregnant women with isolated fetal intrauterine growth restriction: a comparison with preeclamptic women.

    Science.gov (United States)

    Laskowska, Marzena; Laskowska, Katarzyna; Oleszczuk, Jan

    2010-11-01

    This study investigated the serum concentration of soluble CD30 (sCD30) in pregnant women with isolated fetal intrauterine growth restriction, in pregnancies complicated by preeclampsia with and without accompanying intrauterine growth restriction, and in normotensive healthy pregnant controls. Lower serum concentrations of sCD30 were observed in the group of normotensive pregnant women with a growth-restricted fetus in comparison with the group of healthy pregnant controls, and also in comparison with both preeclamptic groups of pregnant women with and without fetal growth restriction. The concentration of sCD30 in maternal serum from preeclamptic women did not differ in comparison with values from healthy controls or pregnancies complicated by isolated fetal intrauterine growth restriction. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  4. 26 CFR 1.6050K-1 - Returns relating to sales or exchanges of certain partnership interests.

    Science.gov (United States)

    2010-04-01

    ..., 30 days after the partnership is notified of the exchange as defined in paragraph (e) of this section...). (2) Notification after Form 1065 is filed. If a partnership is notified of an exchange (as defined in... certain partnership interests. 1.6050K-1 Section 1.6050K-1 Internal Revenue INTERNAL REVENUE SERVICE...

  5. International comparison for RF power in the frequency range up to 18 GHz

    CSIR Research Space (South Africa)

    De Vreede, JPM

    2001-04-01

    Full Text Available A Euromet international laboratory comparison (Project 393) has been carried out between 14 national standards laboratories. Thermistor mounts were used, equipped with PC7 as well as Type N connectors. The comparison is carried out using the normal...

  6. Analysis of internal conversion coefficients

    International Nuclear Information System (INIS)

    Coursol, N.; Gorozhankin, V.M.; Yakushev, E.A.; Briancon, C.; Vylov, Ts.

    2000-01-01

    An extensive database has been assembled that contains the three most widely used sets of calculated internal conversion coefficients (ICC): [Hager R.S., Seltzer E.C., 1968. Internal conversion tables. K-, L-, M-shell Conversion coefficients for Z=30 to Z=103, Nucl. Data Tables A4, 1-237; Band I.M., Trzhaskovskaya M.B., 1978. Tables of gamma-ray internal conversion coefficients for the K-, L- and M-shells, 10≤Z≤104, Special Report of Leningrad Nuclear Physics Institute; Roesel F., Fries H.M., Alder K., Pauli H.C., 1978. Internal conversion coefficients for all atomic shells, At. Data Nucl. Data Tables 21, 91-289] and also includes new Dirac-Fock calculations [Band I.M. and Trzhaskovskaya M.B., 1993. Internal conversion coefficients for low-energy nuclear transitions, At. Data Nucl. Data Tables 55, 43-61]. This database is linked to a computer program to plot ICCs and their combinations (sums and ratios) as a function of Z and energy, as well as relative deviations of ICC or their combinations for any pair of tabulated data. Examples of these analyses are presented for the K-shell and total ICCs of the gamma-ray standards [Hansen H.H., 1985. Evaluation of K-shell and total internal conversion coefficients for some selected nuclear transitions, Eur. Appl. Res. Rept. Nucl. Sci. Tech. 11.6 (4) 777-816] and for the K-shell and total ICCs of high multipolarity transitions (total, K-, L-, M-shells of E3 and M3 and K-shell of M4). Experimental data sets are also compared with the theoretical values of these specific calculations

  7. Comparison of Chinese and European k0 software

    International Nuclear Information System (INIS)

    Sasajima, Fumio

    2004-01-01

    The element determination by neutron activation analysis is commonly done by the relative method using comparison standard materials. However, when a simultaneous multi-element analysis of an unknown sample is carried out, this method requires an advance preparation of reference material for each content element, their simultaneous irradiation with the sample, and measurement in a same condition. It is indeed a demanding technique with the laborious work such as arranging reference materials. On the other hand, the k 0 method does not usually require reference materials, and allows easier and more accurate simultaneous multi-element analysis, therefore it is widely practiced in many countries including European nations. This report describes two kinds of k 0 software (KAYZERO/SOLCOI, ADVNAA) on their characteristics and the results of environmental standard sample (NIST 1632c, NIES No.8, JB-3) analyses using those software. As a result, both of those software accomplished an accuracy within about 10% in analysis of all but a few elements. They have both drawbacks and advantages in their characteristics and features, although it might not be reasonable to compare two products with different development purposes. commercial, or personal use. (author)

  8. Comparison of the air-kerma standards of the PTB and the BIPM in the low-energy X-ray range

    International Nuclear Information System (INIS)

    Burns, D.T.; Bueermann, L.; Kramer, H.M.; Lange, B.

    2001-09-01

    A direct comparison has been made between the air-kerma standards of the Physikalisch-Technische Bundesanstalt (PTB), Germany, and the Bureau International des Poids et Mesures (BIPM) in the x-ray range from 10 kV to 50 kV. Additional measurements were made at 80 kV and 100 kV to provide information on the electron-loss correction for the BIPM standard at these qualities. The comparison took place at the BIPM in March 1999 using the reference conditions recommended by the CCRI. There is general agreement at the level of one standard uncertainty, although there is a significant trend in the results between 30 kV and 50 kVa. This is in part due to the treatment of fluorescence radiation. The effect of fluorescence for the BIPM standard has been calculated using the Monte Carlo code EGSnrc and the fluorescence correction calculated in this way and the effect of including these new values in the present comparison are given. It should be noted, however, that these new correction factors for the BIPM standard have not yet been adopted. The result at 10 kV is significantly different from the others. This is not uncommon and raises a number of possibilities, for example the large corrections for air attenuation and guard wire attenuation, or unexplained aperture effects that have arisen in certain comparisons. In this respect, it is possible that the uncertainties for the 10 kV quality are underestimated. The measurements at 80 kV and 100 kV were made principally to test the correction factors for the BIPM standard, making use of the fact that the large electrode separation of the PTB PK100 chamber results in very little electron loss. (authors)

  9. Synthetic shibkovite K(K{sub 1.67}H{sub 2}O{sub 0.33})(Ca{sub 1.3}Na{sub 0.7})[Zn{sub 3}Si{sub 12}O{sub 30}]: the crystal structure and comparative crystal chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Kiriukhina, G. V., E-mail: g-biralo@yandex.ru; Yakubovich, O. V.; Dimitrova, O. V. [Moscow State University, Faculty of Geology (Russian Federation)

    2015-01-15

    The structure of a single crystal of a synthetic analog of mineral shibkovite K(K{sub 1.67}H{sub 2}O{sub 0.33})(Ca{sub 1.3}Na{sub 0.7})[Zn{sub 3}Si{sub 12}O{sub 30}] (milarite structure type) obtained by hydrothermal synthesis in the AlPO{sub 4}-K{sub 3}PO{sub 4}-CaCO{sub 3}-Na{sub 2}CO{sub 3}-ZnCO{sub 3}-SiO{sub 2}-H{sub 2}O system has been solved (R = 0.0406) by X-ray diffraction analysis: a = 10.5327(2) Å, c = 14.2019(3) Å, sp. gr. P6/mcc, Z = 2, and ρ{sub calcd} = 2.90 g/cm{sup 3}. The crystal-chemical features of the new phase are studied in comparison with the other terms of the milarite group. It is shown that the crystallization conditions for minerals and synthetic analogs of this group determine the presence or absence of crystallization water in the structures of compounds.

  10. International comparison of radon measurement using solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Hu Dan; Yang Weigen; Song Jianfeng

    2011-01-01

    It introduces the radon measurements international comparison using solid state track detectors among Zhejiang Environmental Radiation Monitoring Center (RMTC), Japan Chemical Analysis Center (JCAC) and National Institute for Radiological Protection of China CDC (NIRP). The results of the international comparison show that: Compared to the reference values, the measurements' relative deviations of detectors from 3 labs were 2%∼22%, which were exposed in radon chambers with different radon concentration, while the measurements' relative deviations were 0.5%∼13% when exposed in the environment. The measurement's relative deviations of RMTC were 5%∼3% in radon chambers and 0.5%∼9% in the environment, the results met requirements of the relative standards both at home and abroad. (authors)

  11. Correlation between in-field critical currents in Zr-added (Gd, Y)Ba2Cu3Ox superconducting tapes at 30 and 77 K

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, V; Xu, A; Liu, Y; Khatri, ND; Lei, C; Chen, Y; Galstyan, E; Majkic, G

    2014-03-11

    Critical current (I-c) values of 1384 Lambda/12 mm, corresponding to a critical current density of 12.47 MA cm(-2) and a pinning force of 374 GN m(-3), have been achieved at 30 K, 3 T in the orientation of field parallel to the c axis (B parallel to c) in (Gd, Y)BaCuO tapes with 15 mol% Zr addition made by metal organic chemical vapor deposition (MOCVD). These tapes show pinning force levels as high as 453 GN m(-3) at 30 K. An analysis of the properties of 24-28 (Gd, Y)BaCuO tapes with 15 mol% Zr addition showed a lack of correlation between their critical currents at 30 K, 3 T (B parallel to c) and I-c values both at 77 K, zero field and at 77 K, 1 T (B parallel to c). However, a strong correlation was found between the critical currents at 30 K, 3 T and at 77 K, 3 T (B parallel to c). It has also been discovered that the minimum critical current (I-c, (min)) value at 77 K, 3 T has no influence on the I-c,I- (min) value at 30 K, 3 T, and it in turn depends on the ratio of the I-c values in the orientations of field parallel and perpendicular to the c axis at 77 K, 3 T.

  12. Interlaboratory comparison of measuring results of magnetic field near 400 kV overhead power line

    Directory of Open Access Journals (Sweden)

    Grbić Maja

    2012-01-01

    Full Text Available The paper presents a comparison of measured results of magnetic field near 400 kV overhead power lines obtained by three laboratories. This interlaboratory comparison was performed to ensure confidence in the quality of the test results. The measured results were analyzed with standard methods, using En number, based on which the evaluation of the laboratories was performed.

  13. Comparison of measurement standards of the acoustic pressure in air in the low frequency range: COOMET.AUV.A-K2

    Science.gov (United States)

    Chalyy, V.

    2011-01-01

    A bilateral regional comparison of national microphone standards from 2 Hz to 250 Hz was carried out between the DP NDI 'Systema' (Ukraine) and the VNIIFTRI (Russia) from July to September 2009. The comparison, COOMET.AUV.A-K2, was based on the pressure calibration of laboratory standard microphones type LSIP. The comparison results have been linked to the established key comparison reference value (KCRV) of CCAUV.A-K2. The degrees of equivalence, expressed as the deviation from the established KCRV and its expanded uncertainty (k = 2), have been determined, and the comparison result is in agreement with the KCRV within the estimated uncertainties at all employed frequencies. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  14. Internal friction and shear modulus in Al-Ga alloys (80-320 K)

    International Nuclear Information System (INIS)

    Chountas, K.; Andronikos, P.; Papathanassopoulos, K.

    1977-01-01

    The internal friction and shear modulus of polycrystalline Al + (0.2, 0.7, 2 and 4) at.% Ga was measured as a function of temperature, using measurements of logarithmic decrement and frequency of free sample vibration. The internal friction curves for the smaller solute concentrations went through a maximum (peak) at 230 K. The height of the peak increased initially with solute concentration, then disappeared at higher concentrations. This peak is probably due to the interaction of solute atoms with dislocations. The continuous increase in internal friction at higher temperatures, reported in pure Al, was not found in these alloys. This absence is probably due to the pinning of dislocations by Ga atoms. (author)

  15. TMJ ARTICULAR DISC POSITION AND CONFIGURATION 30 YEARS AFTER INITIAL DIAGNOSIS OF INTERNAL DERANGEMENT

    NARCIS (Netherlands)

    DELEEUW, R; BOERING, G; STEGENGA, B; DEBONT, LGM

    Purpose: This study evaluates disc position and configuration on magnetic resonance imaging (MRI) in temporomandibular joints (TMJs) with a long history of internal derangement. Patients and Methods: Sagittal T1-weighted MRIs of 55 TMJs that were diagnosed with internal derangement approximately 30

  16. Comparison of FSE T2 W PROPELLER and 3D-FIESTA of 3 T MR for the internal auditory canal.

    Science.gov (United States)

    Wu, Hai-Bo; Yuan, Hui-Shu; Ma, Furong; Zhao, Qiang

    The study compared the use of periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique fast spin echo (FSE) T2 W and the sequence of three-dimensional fast imaging employing steady-state acquisition (3D-FIESTA) technique in the MRI of the internal auditory canal for overall image quality improvement. One hundred thirty-two patients undergoing FSE T2 W PROPELLER and 3D-FIESTA examinations of the internal auditory canal were included. All examinations were performed at 3.0 T with comparison of a sagittal oblique FSE T2 W sequence with the PROPELLER technique to 3D-FIESTA in the same reconstructed orientation with PROPELLER. Image quality was evaluated by two radiologists using a 4-point scale. The Wilcoxon signed rank test was used to compare the data of the two techniques. The image quality of FSE T2 W PROPELLER was significantly improved compared to the reconstructed images of 3D-FIESTA. Observer 1: median FSE T2 W with PROPELLER, 4 [mean, 3.455] versus median reconstructed 3D-FIESTA, 3 [mean, 3.15], (PW with PROPELLER, 4 [mean, 3.47] versus median reconstructed 3D-FIESTA, 3 [mean, 3.25], (PW PROPELLER technique for MRI of internal auditory canal reduced uncertainty caused by motion artifact and improved the quality of the image compared to the reconstructed 3D-FIESTA. It was affected by different parameters including the blade width, echo train length (ETL). This is explained by data oversampling at the center region of k-space, which requires additional imaging time over conventional MRI techniques. Increasing blade was expected to improve motion correction effects but also the signal-to-noise ratio. ETL increases the image sharpness and the overall image quality. Copyright © 2016. Published by Elsevier Inc.

  17. Melting-pressure and density equations of 3He at temperatures from 0.001 to 30 K

    International Nuclear Information System (INIS)

    Huang Yonghua; Chen Guobang

    2005-01-01

    Nonsegmented equations for melting pressure and density at temperatures from 0.001 K to 30 K have been developed to fit the reference data. The maximum and average deviations between the melting pressure equation and the totaling 298 reference data are 2.17% and 0.218%, respectively. For the density equations, the average deviations are 0.236% for the liquid side and 0.218% for the solid side. Both the melting pressure curve and melting density curves predicted by the submitted equations approach their minimums at about 0.315 K

  18. On the Reliability of Unit Value Ratios in International Comparisons

    NARCIS (Netherlands)

    Timmer, Marcel P.

    1996-01-01

    In this paper reliability indicators are developed for the Laspeyres and Paasche index type currency conversion factors used in the industry of origin approach to international comparisons of output. Given the fact that these conversion factors are calculated on basis of a sampling technique,

  19. Comparisons on International Approaches of Business and Project Risk Management

    OpenAIRE

    Nadia Carmen ENE

    2005-01-01

    In this article we intend to present a comparative approach between three recognized international methodologies for risk management: RISKMAN, Project Management Institute Methodology-PMBoK and Project Risk Analysis and Management Guide (produced by Association for Project Management).

  20. Markov model plus k-word distributions: a synergy that produces novel statistical measures for sequence comparison.

    Science.gov (United States)

    Dai, Qi; Yang, Yanchun; Wang, Tianming

    2008-10-15

    Many proposed statistical measures can efficiently compare biological sequences to further infer their structures, functions and evolutionary information. They are related in spirit because all the ideas for sequence comparison try to use the information on the k-word distributions, Markov model or both. Motivated by adding k-word distributions to Markov model directly, we investigated two novel statistical measures for sequence comparison, called wre.k.r and S2.k.r. The proposed measures were tested by similarity search, evaluation on functionally related regulatory sequences and phylogenetic analysis. This offers the systematic and quantitative experimental assessment of our measures. Moreover, we compared our achievements with these based on alignment or alignment-free. We grouped our experiments into two sets. The first one, performed via ROC (receiver operating curve) analysis, aims at assessing the intrinsic ability of our statistical measures to search for similar sequences from a database and discriminate functionally related regulatory sequences from unrelated sequences. The second one aims at assessing how well our statistical measure is used for phylogenetic analysis. The experimental assessment demonstrates that our similarity measures intending to incorporate k-word distributions into Markov model are more efficient.

  1. Thermal properties of Permian Basin evaporites to 493 K temperature and 30 MPa confining pressure

    International Nuclear Information System (INIS)

    Durham, W.B.; Heard, H.C.; Boro, C.O.; Keller, K.T.; Ralph, W.E.; Trimmer, D.A.

    1987-03-01

    Laboratory measurements of the thermal conductivity and diffusivity of four rock salts, two anhydrites, and two dolomites bordering Cycle 4 and Cycle 5 bedded salt formations in the Permian Basin in Deaf Smith County, Texas, were made in conditions ranging from 303 to 473 K in temperature and 0.1 to 31.0 MPa in hydrostatic confining pressure. Within the +-5% measurement resolution neither conductivity nor diffusivity showed a dependence upon pressure in any of the rocks. Conductivity and diffusivity in all rocks had a negative temperature dependence. For the Cycle 4 salt samples, conductivity fell from 5.5 to 3.75 W/m . K, and diffusivity fell from about 2.7 to 1.7 x 10 -6 m 2 /s. One Cycle 5 salt was a single crystal with anomalous results, but the other had a low conductivity with very weak temperature dependence and a high diffusivity. In the nonsalts, conductivity and diffusivity decreased 10 to 20% over the temperature range explored. In measurements of the coefficient of thermal linear expansion for Cycle 5 salt and nonsalts, the coefficient typically varied from about 12 x 10 -6 K -1 at P = 3.0 MPa to 4 x 10 -6 K -1 at P = 30 MPa for both nonsalt rocks. In anhydrite, it decreased with increasing temperature. In dolomite, the coefficient increased at roughly the same rate. Expansion of the salt ranged from 33 to 38 x 10 -6 K -1 and was independent of pressure and temperature

  2. Specific heat measurements of TiB2 and 6LiF from 0.5 to 30 K

    International Nuclear Information System (INIS)

    Lang, Brian E.; Donaldson, Marcus H.; Woodfield, Brian F.; Burger, Arnold; Roy, Utupal N.; Lamberti, Vincent; Bell, Zane W.

    2005-01-01

    The specific heats of TiB 2 and 6 LiF have been measured from 0.5 to 30 K as part of a larger project in the construction of a neutron spectrometer. For this application, the measured specific heats were used to extrapolate the specific heats down to 0.1 K with lattice, electronic, and Schottky equations for the respective samples. The resultant specific heat values at 0.1 K for TiB 2 and 6 LiF are 4.08 x 10 -4 ± 0.27 x 10 -4 J/K/mol and 9.19 x 10 -9 ± 0.15 x 10 -9 J/K/mol, respectively

  3. Proceedings of the NEACRP/IAEA Specialists meeting on the international comparison calculation of a large sodium-cooled fast breeder reactor at Argonne National Laboratory on February 7-9, 1978

    International Nuclear Information System (INIS)

    LeSage, L.G.; McKnight, R.D.; Wade, D.C.; Freese, K.E.; Collins, P.J.

    1980-08-01

    The results of an international comparison calculation of a large (1250 MWe) LMFBR benchmark model are presented and discussed. Eight reactor configurations were calculated. Parameters included with the comparison were: eigenvalue, k/sub infinity/, neutron balance data, breeding reaction rate ratios, reactivity worths, central control rod worth, regional sodium void reactivity, core Doppler and effective delayed neutron fraction. Ten countries participated in the comparison, and sixteen solutions were contributed. The discussion focuses on the variation in parameter values, the degree of consistency among the various parameters and solutions, and the identification of unexpected results. The results are displayed and discussed both by individual participants and by groupings of participants

  4. Longitudinal relationships among internalization of the media ideal, peer social comparison, and body dissatisfaction: implications for the tripartite influence model.

    Science.gov (United States)

    Rodgers, Rachel F; McLean, Siân A; Paxton, Susan J

    2015-05-01

    Sociocultural theory of body dissatisfaction posits that internalization of the media ideal and appearance comparison are predictors of body dissatisfaction, a key risk factor for eating disorders. However, no data exist regarding the longitudinal relationships between these variables. The aim of this study was to explore longitudinal relationships among internalization of the media-ideal, social appearance comparison, and body dissatisfaction. A sample of 277 Grade 7 school girls (M age = 12.77 years, SD = 0.44) completed measures of internalization of the media ideal, social appearance comparison, and body dissatisfaction at baseline, 8 months, and 14 months. Path analyses indicated that baseline internalization of the media ideal predicted social appearance comparison and body dissatisfaction at 8 months, and social appearance comparison at 8 months predicted body dissatisfaction at 14 months. A reciprocal effect emerged with body dissatisfaction at 8 months predicting internalization of the media ideal at 14 months. The findings inform sociocultural theory of body dissatisfaction, suggesting that internalization of the media ideal precedes and predicts appearance comparison and that body image interventions that target internalization of the media ideal, and social appearance comparison as well as body dissatisfaction are likely to be effective. (c) 2015 APA, all rights reserved).

  5. Dependence of the K x-ray energy on the mode of excitation

    International Nuclear Information System (INIS)

    Wang, K.C.; Boehm, F.; Hahn, A.A.; Vogel, P.

    1977-01-01

    The energy shifts in the Ta K x rays resulting from the K-capture of 181 W, fluorescence of Ta, and β - decay of 181 Hf followed by internal conversion in 181 Ta are reported. Both W metal and WO 3 on one hand, and Ta metal and Ta 2 O 5 on the other hand, were used. Comparison of the K x-ray energies of the K-capture sources 153 Gd (Eu x rays) and 175 Hf (Lu x rays) and the corresponding fluorescence sources was also made. Various effects which may influence the K x-ray energies are discussed. 9 references

  6. Automatic video shot boundary detection using k-means clustering and improved adaptive dual threshold comparison

    Science.gov (United States)

    Sa, Qila; Wang, Zhihui

    2018-03-01

    At present, content-based video retrieval (CBVR) is the most mainstream video retrieval method, using the video features of its own to perform automatic identification and retrieval. This method involves a key technology, i.e. shot segmentation. In this paper, the method of automatic video shot boundary detection with K-means clustering and improved adaptive dual threshold comparison is proposed. First, extract the visual features of every frame and divide them into two categories using K-means clustering algorithm, namely, one with significant change and one with no significant change. Then, as to the classification results, utilize the improved adaptive dual threshold comparison method to determine the abrupt as well as gradual shot boundaries.Finally, achieve automatic video shot boundary detection system.

  7. Supplementary comparison CCRI(I)-S2 of standards for absorbed dose to water in 60Co gamma radiation at radiation processing dose levels

    DEFF Research Database (Denmark)

    Burns, D. T.; Allisy-Roberts, P. J.; Desrosiers, M. F.

    2011-01-01

    Eight national standards for absorbed dose to water in 60Co gamma radiation at the dose levels used in radiation processing have been compared over the range from 1 kGy to 30 kGy using the alanine dosimeters of the NIST and the NPL as the transfer dosimeters. The comparison was organized...... by the Bureau International des Poids et Mesures, who also participated at the lowest dose level using their radiotherapy-level standard for the same quantity. The national standards are in general agreement within the standard uncertainties, which are in the range from 1 to 2 parts in 102. Evidence of a dose...

  8. An international comparison of surface texture parameters quantification on polymer artefacts using optical instruments

    DEFF Research Database (Denmark)

    Tosello, Guido; Haitjema, H.; Leach, R.K.

    2016-01-01

    An international comparison of optical instruments measuring polymer surfaces with arithmetic mean height values in the sub-micrometre range has been carried out. The comparison involved sixteen optical surface texture instruments (focus variation instruments, confocal microscopes and coherent...

  9. Effects of heat treatments on laser welded Mg-rare earth alloy NZ30K

    International Nuclear Information System (INIS)

    Dai Jun; Huang Jian; Li Min; Li Zhuguo; Dong Jie; Wu Yixiong

    2011-01-01

    Highlights: → Firstly find the tadpole-shape precipitates in the welding joint. → The precipitation strengthening can account for 79% of the total strength. → The results can provide some insights on the application of Mg-RE alloy. - Abstract: In this study, the effects of heat treatments on the quality of laser welded Mg-rare earth alloy NZ30K were systematically studied. The microstructure and mechanical properties of joints, welded by a 15 kW high power CO 2 laser, under different heat treatments had been tested and analyzed. The results indicated that the heat treatment plays an important role in the mechanical strength of laser welded joint of NZ30K. The microstructure of samples after the solution treatment as well as aging treatment is different from that of the as-received welded joint. For solution treatment, although the microstructure is much different from that of as-received welded joint, the solution strengthening effect is not obvious. There are lots of precipitates in the fusion zone after the aging treatment, which will significantly enhance the ultimate tensile strength (UTS) and the yield tensile strength (YTS) of the welding joint. 79% of YTS is caused by precipitation strengthening. Therefore, the results implied that the UTS and YTS can be greatly improved by proper heat treatment.

  10. Mechanical spectroscopy studies of partially amorphous Nd60Fe30Al10 alloys

    International Nuclear Information System (INIS)

    Tarnowski, German C.; Salva, Horacio; Ghilarducci, Ada A.; Urreta, Silvia E.; Billoni, Orlando V.; Fabietti, Luis M.

    2004-01-01

    The hard magnetic properties of melt spun Nd 60 Fe 30 Al 10 alloys are attributed to a major matrix nominally amorphous for X-ray diffraction, composed by two metastable nanosized (∼5 nm) phases with different intrinsic magnetic properties. This composite system is investigated for the first time by mechanical spectroscopy techniques in the temperature range between 50 K and 450 K (1 kHz) where large annealing effects and two damping phenomena are detected. The as-cast microstructure irreversibly changes during annealing above 330 K, leading to a large modulus recovery accompanied by a reduction in the internal friction level. A relatively large relaxation effect is observed about 290 K, evidenced by a narrow internal friction peak with the corresponding step in the elastic modulus; this peak remains stable under thermal cycling between 200 K and 300 K but is affected by aging at 330 K and practically vanishes after heating to 450 K. Another internal friction peak is observed at about 250 K which has associated an anomalous modulus effect; in this temperature range, the internal friction and the elastic modulus exhibit heating/cooling hysteresis, which strongly depends on the extreme temperatures of the thermal cycle, a behavior frequently associated to first-order phase transformations

  11. 30th International Symposium on Computer and Information Sciences

    CERN Document Server

    Gelenbe, Erol; Gorbil, Gokce; Lent, Ricardo

    2016-01-01

    The 30th Anniversary of the ISCIS (International Symposium on Computer and Information Sciences) series of conferences, started by Professor Erol Gelenbe at Bilkent University, Turkey, in 1986, will be held at Imperial College London on September 22-24, 2015. The preceding two ISCIS conferences were held in Krakow, Poland in 2014, and in Paris, France, in 2013.   The Proceedings of ISCIS 2015 published by Springer brings together rigorously reviewed contributions from leading international experts. It explores new areas of research and technological development in computer science, computer engineering, and information technology, and presents new applications in fast changing fields such as information science, computer science and bioinformatics.   The topics covered include (but are not limited to) advances in networking technologies, software defined networks, distributed systems and the cloud, security in the Internet of Things, sensor systems, and machine learning and large data sets.

  12. Colleagues and Competitors: How Internal Social Comparisons Shape Organizational Search and Adaptation

    DEFF Research Database (Denmark)

    Baumann, Oliver; Eggers, JP; Stieglitz, Nils

    2018-01-01

    Intra-organizational comparisons—managers and units benchmarking their performance against each other—can turn colleagues into competitors. To better understand when organizations should allow or even encourage internal social comparisons, we study their implications for organizational adaptation....... We highlight empirical implications and discuss theoretical links to work on intra-organizational competition, social comparisons and aspiration-driven search, diversification and performance, and the adaptation of multi-business firms....

  13. Inter-RMO Key Comparison EUROMET.L-K5.2004: Calibration of a step gauge

    DEFF Research Database (Denmark)

    Prieto, Emilio; Brown, Nicholas; Lassila, Antti

    2012-01-01

    The results of the inter-RMO key comparison EUROMET.L-K5.2004 on the calibration of a step gauge are reported. Eighteen National Metrology Institutes and one Designated Institute from four different metrological regions all over the world participated in this comparison which lasted three years...... value. Due to the significant instability of the step it was also considered an artefact uncertainty. The reported uncertainties ranged from 0.045 µm to 1.2 µm (k = 1). The uncertainty of the artefact ranged from 0.018 µm (for the 20 mm face) to 0.176 µm (for the 400 mm face). The compatibility of all...... participants for measuring step gauges was demonstrated with the only exception of a participant showing very high systematic (both positive and negative) errors. Five participants communicated higher uncertainties than the corresponding approved CMCs. A set of Recommendations and Actions were agreed therefore...

  14. Comparison report for CSNI International Standard Problem 12 (ROSA-III Run 912)

    International Nuclear Information System (INIS)

    Tasaka, Kanji; Anoda, Yoshinari; Kumamaru, Hiroshige; Nakamura, Hideo; Iriko, Masanori; Yonomoto, Taisuke; Shiba, Masayoshi

    1982-09-01

    ROSA-III Run 912 was identified as International Standard Problem 12 by the Committee on the Safety of Nuclear Installations. Run 912 simulated a 5% split break LOCA condition in a BWR at the pump suction in the recirculation line with the HPCS failure. Comparisons between the test data and the calculations by eight international participants were made and discussed. (author)

  15. Youth delinquency in Slovenia in international comparison

    OpenAIRE

    Dekleva, Bojan

    2015-01-01

    The article analyzes the official statistics of youth delinquency in Slovenia over the last 30 years. It presents an overview of Slovenian studies of youth delinquency using the self-report surveying method, and describes the International Self-Reported Delinquency Study II, which Slovenia was also took part in. And finally, it analyzes the information, on the basis of which it is possible to formulate conclusions on the extent of youth delinquency in Slovenia compared...

  16. Youth delinquency in Slovenia in international comparison

    OpenAIRE

    Dekleva, Bojan

    2010-01-01

    The article analyzes the official statistics of youth delinquency in Slovenia over the last 30 years. It presents an overview of Slovenian studies of youth delinquency using the self-report surveying method, and describes the International Self-Reported Delinquency Study II, which Slovenia was also took part in. And finally, it analyzes the information, on the basis of which it is possible to formulate conclusions on the extent of youth delinquency in Slovenia compared...

  17. [Surgical research in Germany--an international comparison].

    Science.gov (United States)

    Fendrich, V; Rothmund, M

    2010-04-01

    Surgical research in Germany occupies a lower position in international ranking than expected. According to the size of the population, the economic impact, the gross domestic product and the research funding capacity, the impact of German surgical research should be much higher. Reasons are a more intensive commitment to patient care, structural differences and a changing lifestyle in younger doctors in comparison to many leading countries. If the situation is to be improved all factors have to be evaluated and, if possible, changed. Overall, German surgeons are underrepresented as readers and authors in the scientific market, which is mostly in the English language.

  18. Polarization and CP asymmetries in the decays B→K*ψ, K*ω, and K

    International Nuclear Information System (INIS)

    Kramer, G.; Palmer, W.F.

    1991-11-01

    We calculate branching ratios, polarization and CP asymmetries for the final exclusive states K * ψ, K * ω, K * ρ, make comparisons with experimental data, and suggest further tests of the underlying theoretical framework. (orig.)

  19. Offshore code comparison collaboration continuation within IEA Wind Task 30: Phase II results regarding a floating semisubmersible wind system

    DEFF Research Database (Denmark)

    Robertson, Amy; Jonkman, Jason M.; Vorpahl, Fabian

    2014-01-01

    Offshore wind turbines are designed and analyzed using comprehensive simulation tools (or codes) that account for the coupled dynamics of the wind inflow, aerodynamics, elasticity, and controls of the turbine, along with the incident waves, sea current, hydrodynamics, mooring dynamics, and founda......Offshore wind turbines are designed and analyzed using comprehensive simulation tools (or codes) that account for the coupled dynamics of the wind inflow, aerodynamics, elasticity, and controls of the turbine, along with the incident waves, sea current, hydrodynamics, mooring dynamics......, and foundation dynamics of the support structure. This paper describes the latest findings of the code-to-code verification activities of the Offshore Code Comparison Collaboration Continuation project, which operates under the International Energy Agency Wind Task 30. In the latest phase of the project......, participants used an assortment of simulation codes to model the coupled dynamic response of a 5-MW wind turbine installed on a floating semisubmersible in 200 m of water. Code predictions were compared from load case simulations selected to test different model features. The comparisons have resulted...

  20. Isotope dilution mass spectrometry as the primary method of measurement for the amount of matter. Application to cadmium determination in biological materials and comparison with instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Munoz, Luis; Gras, Nuri; Quejido, Alberto; Ferrada, Carlos

    2001-01-01

    A primary method of measurement as defined by the Consultative Committee on the Quantity of Matter (Comite Consultatif pour la Quantite de Matiere, CCQM) of the International Bureau of Weights and Measurements (Bureau International des Poids et Mesures, BIPM), is one whose measurement process is perfectly known, has valid theoretical foundations and is fully described and answers to an equation that relates what is measured with what is intended to be measured without any significant empirical correction factors. It is also a method that has insignificant systematic errors, where only magnitudes from the International System of Units (SI) are used and where, preferably, the uncertainties are small ones. They are, therefore, procedures that do not need instrumental calibration. The absolute methods of measurement allow a chain of traceability to be formed between the result obtained and the magnitude of the SI assigned to what is measured. So the results are said to be traceable to the SI. One of the methods that meets these requirements and is recognized as the primary method by the CCQM is Isotope Dilution Mass Spectrometry (IDMS). Through a project of Technical Cooperation with the International Atomic Energy Agency in the area of Chemical Metrology, the CCHEN obtained training in CIEMAT, Spain, in IDMS and its applications to the analysis of biological samples. This work describes the first experience carried out entirely in Chilean laboratories, applying IDMS to the determination of cadmium in the biological reference materials Oyster Tissue 15566-A from the NIST, United States, Dogfish Liver, DOLT-2 from the NRC-CNRC, Canada and Poplar Leaves GBW07604 from the NRCC, China. The samples were traced with an isotope enriched spike 111 Cd and then shaken to obtain the isotopic exchange. Once dissolved, the isotopic relationship 111 Cd/ 114 Cd was determined in the samples using mass spectrometry with plasma source. These results were compared with those obtained

  1. Preparation and characterization of celecoxib solid dispersions; comparison of poloxamer-188 and PVP-K30 as carriers

    Directory of Open Access Journals (Sweden)

    Alireza Homayouni

    2014-05-01

    Full Text Available Objective(s:Solid dispersion formulation is the most promising strategy to improve oral bioavailability of poorly water soluble drugs. The aim of this study was to compare the effect of polyvinylpyrrolidone K30 (PVP and poloxamer-188 (PLX as carrier in solid dispersion formulations of celecoxib (CLX. Materials and Methods: Solid dispersions of CLX:PVP or CLX:PLX were prepared at different ratios (2:1, 1:1, 1:2, 1:4, 1:6 by solvent evaporation and melting methods, respectively. The characterization of samples was performed using differential scanning calorimetery (DSC, X-Ray powder diffraction (XRPD and Fourier transform infrared spectroscopy (FT-IR. The Gordon-Taylor equation was used to estimate the Tg of solid dispersion systems and the possibility of the interaction between CLX and PVP. Also, the dissolution rate of all samples was determined. Results: DSC and XRPD analyses confirmed the presence of amorphous state of drug in solid dispersion systems. FT-IR studies showed CLX could participate in hydrogen bonding with PVP whilst no specific interaction between CLX and PLX was observed. Both PVP and PLX enhanced the dissolution rate of drug in solid dispersion samples. The dissolution rate was dependent on the ratio of drug: carrier. Interestingly, the solid dispersion samples of PLX at 2:1 and 1:1 drug: carrier showed slower dissolution rate than pure CLX, whilst these results were not observed for PVP. Conclusion: The effect of PVP on dissolution rate enhancement was more pronounced compared to the other carrier. Having a higher Tg and more effect on dissolution rate, PVP could be considered as a more suitable carrier compared to PLX in solid dispersion formulation of CLX.

  2. The Power of Cooperation in International Paleoclimate Science: Examples from the PAGES 2k Network and the Ocean2k Working Group

    Science.gov (United States)

    Addison, J. A.

    2015-12-01

    The Past Global Changes (PAGES) project of IGBP and Future Earth supports research to understand the Earth's past environment to improve future climate predictions and inform strategies for sustainability. Within this framework, the PAGES 2k Network was established to provide a focus on the past 2000 years, a period that encompasses Medieval Climate Anomaly warming, Little Ice Age cooling, and recent anthropogenically-forced climate change. The results of these studies are used for testing earth system models, and for understanding decadal- to centennial-scale variability, which is needed for long-term planning. International coordination and cooperation among the nine regional Working Groups that make up the 2k Network has been critical to the success of PAGES 2k. The collaborative approach is moving toward scientific achievements across the regional groups, including: (i) the development of a community-driven open-access proxy climate database; (ii) integration of multi-resolution proxy records; (iii) development of multivariate climate reconstructions; and (iv) a leap forward in the spatial resolution of paleoclimate reconstructions. The last addition to the 2k Network, the Ocean2k Working Group has further innovated the collaborative approach by: (1) creating an open, receptive environment to discuss ideas exclusively in the virtual space; (2) employing an array of real-time collaborative software tools to enable communication, group document writing, and data analysis; (3) consolidating executive leadership teams to oversee project development and manage grassroots-style volunteer pools; and (4) embracing the value-added role that international and interdisciplinary science can play in advancing paleoclimate hypotheses critical to understanding future change. Ongoing efforts for the PAGES 2k Network are focused on developing new standards for data quality control and archiving. These tasks will provide the foundation for new and continuing "trans-regional" 2k

  3. Towards an international authoritative system for coordination and management of a unique recommended k0-NAA database

    International Nuclear Information System (INIS)

    De Corte, F.

    2010-01-01

    This paper describes the evolution of the database in k 0 -standardized neutron activation analysis (k 0 -NAA), ranging from its full supervision by the founders of the k 0 -method at the Institute for Nuclear Sciences (INW)/Gent and the Central Research Institute for Physics (KFKI)/Budapest (from about the mid 1970s up to the early 1990s), to the present situation (roughly speaking starting with the first k 0 Users Workshop in 1992) where an increasing number of researchers from institutes allover the world are reporting on their experimental work aiming at the improvement and extension of the existing database. Although these individual contributions are undoubtedly commendable, the resulting fragmentary data sets leave behind important questions with respect to interpretation, evaluation, integration and recommendation, as illustrated with the (extreme) example of 131 Ba. This situation urgently calls for establishing and managing an international authoritative system for the coordination and quality control of a unique database with recommended data for k 0 -NAA, considering such parameters as accuracy, traceability and consistency. In the present paper, it is proposed to entrust this task to a standing 'Reference k 0 -Data Subcommittee' of the k 0 -ISC (k 0 International Scientific Committee).

  4. Report of the key-comparison of spectral diffuse reflectance (EURAMET.PR-K5) (Ref. 619)

    Science.gov (United States)

    Andor, György; Gál, Péter

    2018-01-01

    This report details the final results of the EURAMET comparison on regular spectral transmittance carried out between 2006 and 2016. The aim of this comparison was to check the agreement of measurement of the spectral diffuse reflectance among participants, using the measurement geometry of d/0 or 0/d in the wavelength range of 360 nm to 780 nm at 20 nm increment. We used a star type comparison: first the participants sent their samples to the pilot, than the pilot measured all the samples of the participants and sent them back. The participants measured the samples and sent them to the pilot for control measurement. Six standards were used as reference standards in order to maintain the scale during the comparison. These were three samples of BCR-406 opal glasses (BCR 30506; BCR 30303; BCR 30704), an MC20 Russian opal glass (MC 4777) and two samples made of pressed halon (polytetrafluoroethylene) powder (halon 2007A; halon 2007C). These six samples were designated as the Comparison reference standards. The diffuse reflectance was initially measured on the OMH (BFKH) absolute reflectometer. The link to the CCPR-K5 results was BFKH, and the check on BFKH was the PTB results who also participated in the CCPR-K5 comparison. The participants were GUM, INM, LNE, METAS, BFKH, PTB, SP. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Internal services simulation control in 220/110kV power transformer station Mintia

    Science.gov (United States)

    Ciulica, D.; Rob, R.

    2018-01-01

    The main objectives in developing the electric transport and distribution networks infrastructure are satisfying the electric energy demand, ensuring the continuity of supply to customers, minimizing electricity losses in the transmission and distribution networks of public interest. This paper presents simulations in functioning of the internal services system 400/230 V ac in the 220/110 kV power transformer station Mintia. Using simulations in Visual Basic, the following premises are taken into consideration. All the ac consumers of the 220/110 kV power transformer station Mintia will be supplied by three 400/230 V transformers for internal services which can mutual reserve. In case of damaging at one transformer, the others are able to assume the entire consumption using automatic release of reserves. The simulation program studies three variants in which the continuity of supply to customers are ensured. As well, by simulations, all the functioning situations are analyzed in detail.

  6. Structure of the 30 kDa HIV-1 RNA Dimerization Signal by a Hybrid Cryo-EM, NMR, and Molecular Dynamics Approach.

    Science.gov (United States)

    Zhang, Kaiming; Keane, Sarah C; Su, Zhaoming; Irobalieva, Rossitza N; Chen, Muyuan; Van, Verna; Sciandra, Carly A; Marchant, Jan; Heng, Xiao; Schmid, Michael F; Case, David A; Ludtke, Steven J; Summers, Michael F; Chiu, Wah

    2018-03-06

    Cryoelectron microscopy (cryo-EM) and nuclear magnetic resonance (NMR) spectroscopy are routinely used to determine structures of macromolecules with molecular weights over 65 and under 25 kDa, respectively. We combined these techniques to study a 30 kDa HIV-1 dimer initiation site RNA ([DIS] 2 ; 47 nt/strand). A 9 Å cryo-EM map clearly shows major groove features of the double helix and a right-handed superhelical twist. Simulated cryo-EM maps generated from time-averaged molecular dynamics trajectories (10 ns) exhibited levels of detail similar to those in the experimental maps, suggesting internal structural flexibility limits the cryo-EM resolution. Simultaneous inclusion of the cryo-EM map and 2 H-edited NMR-derived distance restraints during structure refinement generates a structure consistent with both datasets and supporting a flipped-out base within a conserved purine-rich bulge. Our findings demonstrate the power of combining global and local structural information from these techniques for structure determination of modest-sized RNAs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Stroke Impact Scale 3.0: Reliability and Validity Evaluation of the Korean Version.

    Science.gov (United States)

    Choi, Seong Uk; Lee, Hye Sun; Shin, Joon Ho; Ho, Seung Hee; Koo, Mi Jung; Park, Kyoung Hae; Yoon, Jeong Ah; Kim, Dong Min; Oh, Jung Eun; Yu, Se Hwa; Kim, Dong A

    2017-06-01

    To establish the reliability and validity the Korean version of the Stroke Impact Scale (K-SIS) 3.0. A total of 70 post-stroke patients were enrolled. All subjects were evaluated for general characteristics, Mini-Mental State Examination (MMSE), the National Institutes of Health Stroke Scale (NIHSS), Modified Barthel Index, Hospital Anxiety and Depression Scale (HADS). The SF-36 and K-SIS 3.0 assessed their health-related quality of life. Statistical analysis after evaluation, determined the reliability and validity of the K-SIS 3.0. A total of 70 patients (mean age, 54.97 years) participated in this study. Internal consistency of the SIS 3.0 (Cronbach's alpha) was obtained, and all domains had good co-efficiency, with threshold above 0.70. Test-retest reliability of SIS 3.0 required correlation (Spearman's rho) of the same domain scores obtained on the first and second assessments. Results were above 0.5, with the exception of social participation and mobility. Concurrent validity of K-SIS 3.0 was assessed using the SF-36, and other scales with the same or similar domains. Each domain of K-SIS 3.0 had a positive correlation with corresponding similar domain of SF-36 and other scales (HADS, MMSE, and NIHSS). The newly developed K-SIS 3.0 showed high inter-intra reliability and test-retest reliabilities, together with high concurrent validity with the original and various other scales, for patients with stroke. K-SIS 3.0 can therefore be used for stroke patients, to assess their health-related quality of life and treatment efficacy.

  8. International comparison of activity measurements of a solution of 75Se

    Science.gov (United States)

    Ratel, Guy

    2002-04-01

    Activity measurements of a solution of 75Se, supplied by the BIPM, have been carried out by 21 laboratories within the framework of an international comparison. Seven different methods were used. Details on source preparation, experimental facilities and counting data are reported. The measured activity-concentration values show a total spread of 6.62% before correction and 6.02% after correction for delayed events, with standard deviations of the unweighted means of 0.45% and 0.36%, respectively. The correction for delayed events was measured directly by four laboratories. Unfortunately no consensus on the activity value could be deduced from their results. The results of the comparison have been entered in the tables of the International Reference System (SIR) for γ-ray emitting radionuclides. The half-life of the metastable state was also determined by two laboratories and found to be in good agreement with the values found in the literature.

  9. Report to the CCT on COOMET comparison COOMET.T-K3.1 (previously COOMET.T-S1): Key regional comparison of the national standards of temperature in the range from the triple point of water to the freezing point of zinc

    Science.gov (United States)

    Pokhodun, A. I.

    2010-01-01

    In the framework of the CIPM MRA, a first COOMET comparison "Comparison of the ITS-90 realizations in the range from 0.01 °C to 429.7485 °C (from the triple point of water to the freezing point of zinc)", registered in the KCDB under the identifier "COOMET.T-K3", was carried out in 2005-2007. Four national metrology institutes took part in this comparison: VNIIM (Russian Federation), SMU (Slovakia), BelGIM (Republic of Belarus) and NSC IM (Ukraine), and two of them (VNIIM and SMU) ensured the linkage with key comparisons CCT-K3 and CCT-K4, in order to disseminate the metrological equivalence to the measurement standards of NSC IM and BelGIM. NSC IM, however, had to withdraw its results, and at the meeting of Technical Committee T-10 of COOMET it was decided to carry out a supplementary bilateral comparison between VNIIM and the NSC IM for realization of the ITS-90 in the same range of temperature. This was registered in the KCDB under the identifier COOMET.T-S1 and measurements were performed in 2008-2009. From the results presented in this report, it is possible to draw the conclusion that the COOMET supplementary comparison COOMET.T-S1 demonstrates the CMC uncertainties claimed by the NSC IM for the melting point of gallium 0.236 mK (k = 2), and the freezing points of indium 1.040 mK (k = 2), tin 0.858 mK (k = 2) and zinc 0.944 mK (k = 2). In September 2012 the Working Group on key Comparisons (WG 7) of the CCT upgraded this comparison to a COOMET key comparison of the 'CCT-K3' type. It is now identified as COOMET.T-K3.1. In April 2013 this report was superseded by item 03006 in the Technical Supplement of 2013. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  10. The pressure, internal energy, and conductivity of tantalum plasma

    Energy Technology Data Exchange (ETDEWEB)

    Apfelbaum, E.M. [Russian Academy of Sciences, Joint Institute for High Temperatures, Department of Computational Physics, Moscow (Russian Federation)

    2017-11-15

    The pressure, internal energy, and conductivity of a tantalum plasma were calculated at the temperatures 10-100 kK and densities less than 3 g/cm{sup 3}. The plasma composition, pressure, and internal energy were obtained by means of the corresponding system of the coupled mass action law equations. We have considered atom ionization up to +3. The conductivity was calculated within the relaxation time approximation. Comparisons of our results with available measurements and calculation data show good agreement in the area of correct applicability of the present model. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  11. Probing ultrafast ππ*/nπ* internal conversion in organic chromophores via K-edge resonant absorption

    DEFF Research Database (Denmark)

    Wolf, T. J. A.; Myhre, Rolf H.; Cryan, J. P.

    2017-01-01

    -edge soft X-ray absorption spectroscopy. As a hole forms in the n orbital during ππ*/nπ* internal conversion, the absorption spectrum at the heteroatom K-edge exhibits an additional resonance. We demonstrate the concept using the nucleobase thymine at the oxygen K-edge, and unambiguously show that ππ...

  12. Results submitted to Bureau International des Poids et Mesures (BIPM) for international comparison on 134Cs activity

    International Nuclear Information System (INIS)

    Gibson, F.H.; Smith, L.V.; Rutledge, A.R.; Merritt, J.S.

    1979-02-01

    This report describes the equipment used and the results obtained by the Radioisotope Standardization Group in its participation in the international comparison of activity measurements of a 134 Cs solution that was sponsored by Bureau International des Poids et Mesures (BIPM). The 4π(PC)-γ coincidence method was used with the γ-channel gate set narrowly around photopeaks of approximately 800 keV. The results are compared with those from three other γ-channel gates. An assessment of known and suspected sources of uncertainty is included. (author)

  13. Wind Power Forecasting Error Distributions: An International Comparison

    DEFF Research Database (Denmark)

    Hodge, Bri-Mathias; Lew, Debra; Milligan, Michael

    2012-01-01

    Wind power forecasting is essential for greater penetration of wind power into electricity systems. Because no wind forecasting system is perfect, a thorough understanding of the errors that may occur is a critical factor for system operation functions, such as the setting of operating reserve...... levels. This paper provides an international comparison of the distribution of wind power forecasting errors from operational systems, based on real forecast data. The paper concludes with an assessment of similarities and differences between the errors observed in different locations....

  14. True Multilateral Indexes for International Comparisons of Purchasing Power and Real Income

    OpenAIRE

    J.P. Neary

    1997-01-01

    I consider the problem of choosing index numbers of purchasing power and real income for international comparisons. I show that the desirable properties of methods based on the Fisher "Ideal" index do not extend to multilateral comparisons, except when tastes are homothetic. By contrast, the Geary method, which underlies the Penn World Tables, provides an approximation to a set of "true" exchange rate indexes which have many desirable properties. In particular, if demands exhibit generalized ...

  15. Laser cutting of thick steel plates with 30 kW fiber laser for nuclear decommissioning

    International Nuclear Information System (INIS)

    Tamura, Koji

    2015-01-01

    Laser cutting technologies of the thick steel plates for the nuclear decommissioning were developed with a 30 kW fiber laser. Plates of stainless steel and carbon steel more than 100 mm thick were successfully cut, indicating that this technology is promising for the application to the nuclear decommissioning. (author)

  16. Bilateral comparison of 100 pF standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the NSAI-NML (Ireland) and the BIPM

    Science.gov (United States)

    Gournay, Pierre; Power, Oliver

    2017-01-01

    This report presents the results of a bilateral comparison of capacitance at 100 pF between the NSAI-NML (Ireland) and the BIPM carried out in 2016. This comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.b in which the BIPM is the pilot laboratory. Two 100 pF travelling standards belonging to the BIPM were used in this comparison carried out with an 'A-B-A' pattern of measurements. The standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz, for a measuring rms voltage of 15 V. The results from the NSAI-NML and the BIPM were found to be in relatively good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of 0.85 × 10-6. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Energy study of heat pumps and energy storage at Cisco Systems International; Energiestudie warmtepompen en energieopslag Cisco Systems International

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-05-23

    Cisco Systems International considers the use of energy storage in combination with heat pumps for the new office building in Amsterdam South-East, Netherlands. This office building has a floor space of 35,000 m{sup 2}. In a later phase this can be enlarged to 45,000 m{sup 2} (phase 1b) or 90,000 m{sup 2} (phase 2). This study is based on phase 1b. The mounting heat capacity is 2,760 kW and the cooling capacity is 7,045 kW. The annually cooling demand is estimated to be 30,400 MWh/a. The computer cooling forms a greater part of the cooling request (28,300 MWh/a). This study is a pilot study to the applicability of subsurface energy storage where heat pumps in the new office building are involved. However, nearby the Cisco location IKEA (furniture warehouse) has also planned an energy storage system. Therefore, the interaction between the two storage systems was examined. Cost effectiveness was analysed by comparison of the storage system with an energy system using conventional cooling machines and gas boilers. 5 refs.

  18. 75 FR 36455 - SSE Telecom, Inc., Strategic Alliance Group, Inc., (n/k/a CruiseCam International, Inc...

    Science.gov (United States)

    2010-06-25

    ... SECURITIES AND EXCHANGE COMMISSION [File No. 500-1] SSE Telecom, Inc., Strategic Alliance Group, Inc., (n/k/a CruiseCam International, Inc.), Stratasec, Inc., Superfly Advertising, Inc. (f/k/a Morlex... a lack of current and accurate information concerning the securities of Strategic Alliance Group...

  19. 30-kW SEP Spacecraft as Secondary Payloads for Low-Cost Deep Space Science Missions

    Science.gov (United States)

    Brophy, John R.; Larson, Tim

    2013-01-01

    The Solar Array System contracts awarded by NASA's Space Technology Mission Directorate are developing solar arrays in the 30 kW to 50 kW power range (beginning of life at 1 AU) that have significantly higher specific powers (W/kg) and much smaller stowed volumes than conventional rigid-panel arrays. The successful development of these solar array technologies has the potential to enable new types of solar electric propulsion (SEP) vehicles and missions. This paper describes a 30-kW electric propulsion vehicle built into an EELV Secondary Payload Adapter (ESPA) ring. The system uses an ESPA ring as the primary structure and packages two 15-kW Megaflex solar array wings, two 14-kW Hall thrusters, a hydrazine Reaction Control Subsystem (RCS), 220 kg of xenon, 26 kg of hydrazine, and an avionics module that contains all of the rest of the spacecraft bus functions and the instrument suite. Direct-drive is used to maximize the propulsion subsystem efficiency and minimize the resulting waste heat and required radiator area. This is critical for packaging a high-power spacecraft into a very small volume. The fully-margined system dry mass would be approximately 1120 kg. This is not a small dry mass for a Discovery-class spacecraft, for example, the Dawn spacecraft dry mass was only about 750 kg. But the Dawn electric propulsion subsystem could process a maximum input power of 2.5 kW, and this spacecraft would process 28 kW, an increase of more than a factor of ten. With direct-drive the specific impulse would be limited to about 2,000 s assuming a nominal solar array output voltage of 300 V. The resulting spacecraft would have a beginning of life acceleration that is more than an order of magnitude greater than the Dawn spacecraft. Since the spacecraft would be built into an ESPA ring it could be launched as a secondary payload to a geosynchronous transfer orbit significantly reducing the launch costs for a planetary spacecraft. The SEP system would perform the escape

  20. Association Between Treatment by Locum Tenens Internal Medicine Physicians and 30-Day Mortality Among Hospitalized Medicare Beneficiaries.

    Science.gov (United States)

    Blumenthal, Daniel M; Olenski, Andrew R; Tsugawa, Yusuke; Jena, Anupam B

    2017-12-05

    Use of locum tenens physicians has increased in the United States, but information about their quality and costs of care is lacking. To evaluate quality and costs of care among hospitalized Medicare beneficiaries treated by locum tenens vs non-locum tenens physicians. A random sample of Medicare fee-for-service beneficiaries hospitalized during 2009-2014 was used to compare quality and costs of hospital care delivered by locum tenens and non-locum tenens internal medicine physicians. Treatment by locum tenens general internal medicine physicians. The primary outcome was 30-day mortality. Secondary outcomes included inpatient Medicare Part B spending, length of stay, and 30-day readmissions. Differences between locum tenens and non-locum tenens physicians were estimated using multivariable logistic regression models adjusted for beneficiary clinical and demographic characteristics and hospital fixed effects, which enabled comparisons of clinical outcomes between physicians practicing within the same hospital. In prespecified subgroup analyses, outcomes were reevaluated among hospitals with different levels of intensity of locum tenens physician use. Of 1 818 873 Medicare admissions treated by general internists, 38 475 (2.1%) received care from a locum tenens physician; 9.3% (4123/44 520) of general internists were temporarily covered by a locum tenens physician at some point. Differences in patient characteristics, demographics, comorbidities, and reason for admission between locum tenens and non-locum tenens physicians were not clinically relevant. Treatment by locum tenens physicians, compared with treatment by non-locum tenens physicians (n = 44 520 physicians), was not associated with a significant difference in 30-day mortality (8.83% vs 8.70%; adjusted difference, 0.14%; 95% CI, -0.18% to 0.45%). Patients treated by locum tenens physicians had significantly higher Part B spending ($1836 vs $1712; adjusted difference, $124; 95% CI, $93 to $154

  1. Validity of Chinese Version of the Composite International Diagnostic Interview-3.0 in Psychiatric Settings

    Institute of Scientific and Technical Information of China (English)

    Jin Lu; Yue-Qin Huang; Zhao-Rui Liu; Xiao-Lan Cao

    2015-01-01

    Background:The Composite International Diagnostic Interview-3.0 (CIDI-3.0) is a fully structured lay-administered diagnostic interview for the assessment of mental disorders according to ICD-10 and Diagnostic and Statistical Manual of Mental Disorders,Fourth Edition (DSM-Ⅳ) criteria.The aim of the study was to investigate the concurrent validity of the Chinese CIDI in diagnosing mental disorders in psychiatric settings.Methods:We recruited 208 participants,of whom 148 were patients from two psychiatric hospitals and 60 healthy people from communities.These participants were administered with CIDI by six trained lay interviewers and the Structured Clinical Interview for DSM-Ⅳ Axis I Disorders (SCID-I,gold standard) by two psychiatrists.Agreement between CIDI and SCID-I was assessed with sensitivity,specificity,positive predictive value and negative predictive value.Individual-level CIDI-SCID diagnostic concordance was evaluated using the area under the receiver operator characteristic curve and Cohen's K.Results:Substantial to excellent CIDI to SCID concordance was found for any substance use disorder (area under the receiver operator characteristic curve [AUC] =0.926),any anxiety disorder (AUC =0.807) and any mood disorder (AUC =0.806).The concordance between the CIDI and the SCID for psychotic and eating disorders is moderate.However,for individual mental disorders,the CIDI-SCID concordance for bipolar disorders (AUC =0.55) and anorexia nervosa (AUC =0.50) was insufficient.Conclusions:Overall,the Chinese version of CIDI-3.0 has acceptable validity in diagnosing the substance use disorder,anxiety disorder and mood disorder among Chinese adult population.However,we should be cautious when using it for bipolar disorders and anorexia nervosa.

  2. Validity of Chinese Version of the Composite International Diagnostic Interview-3.0 in Psychiatric Settings

    Directory of Open Access Journals (Sweden)

    Jin Lu

    2015-01-01

    Full Text Available Background: The Composite International Diagnostic Interview-3.0 (CIDI-3.0 is a fully structured lay-administered diagnostic interview for the assessment of mental disorders according to ICD-10 and Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV criteria. The aim of the study was to investigate the concurrent validity of the Chinese CIDI in diagnosing mental disorders in psychiatric settings. Methods: We recruited 208 participants, of whom 148 were patients from two psychiatric hospitals and 60 healthy people from communities. These participants were administered with CIDI by six trained lay interviewers and the Structured Clinical Interview for DSM-IV Axis I Disorders (SCID-I, gold standard by two psychiatrists. Agreement between CIDI and SCID-I was assessed with sensitivity, specificity, positive predictive value and negative predictive value. Individual-level CIDI-SCID diagnostic concordance was evaluated using the area under the receiver operator characteristic curve and Cohen′s K. Results: Substantial to excellent CIDI to SCID concordance was found for any substance use disorder (area under the receiver operator characteristic curve [AUC] = 0.926, any anxiety disorder (AUC = 0.807 and any mood disorder (AUC = 0.806. The concordance between the CIDI and the SCID for psychotic and eating disorders is moderate. However, for individual mental disorders, the CIDI-SCID concordance for bipolar disorders (AUC = 0.55 and anorexia nervosa (AUC = 0.50 was insufficient. Conclusions: Overall, the Chinese version of CIDI-3.0 has acceptable validity in diagnosing the substance use disorder, anxiety disorder and mood disorder among Chinese adult population. However, we should be cautious when using it for bipolar disorders and anorexia nervosa.

  3. Factors associated with intern noncompliance with the 2003 Accreditation Council for Graduate Medical Education's 30-hour duty period requirement.

    Science.gov (United States)

    Maloney, Christopher G; Antommaria, Armand H Matheny; Bale, James F; Ying, Jian; Greene, Tom; Srivastava, Rajendu

    2012-07-13

    In 2003 the Accreditation Council for Graduate Medical Education mandated work hour restrictions. Violations can results in a residency program being cited or placed on probation. Recurrent violations could results in loss of accreditation. We wanted to determine specific intern and workload factors associated with violation of a specific mandate, the 30-hour duty period requirement. Retrospective review of interns' performance against the 30-hour duty period requirement during inpatient ward rotations at a pediatric residency program between June 24, 2008 and June 23, 2009. The analytical plan included both univariate and multivariable logistic regression analyses. Twenty of the 26 (77%) interns had 80 self-reported episodes of continuous work hours greater than 30 hours. In multivariable analysis, noncompliance was inversely associated with the number of prior inpatient rotations (odds ratio: 0.49, 95% confidence interval (0.38, 0.64) per rotation) but directly associated with the total number of patients (odds ratio: 1.30 (1.10, 1.53) per additional patient). The number of admissions on-call, number of admissions after midnight and number of discharges post-call were not significantly associated with noncompliance. The level of noncompliance also varied significantly between interns after accounting for intern experience and workload factors. Subject to limitations in statistical power, we were unable to identify specific intern characteristics, such as demographic variables or examination scores, which account for the variation in noncompliance between interns. Both intern and workload factors were associated with pediatric intern noncompliance with the 30-hour duty period requirement during inpatient ward rotations. Residency programs must develop information systems to understand the individual and experience factors associated with noncompliance and implement appropriate interventions to ensure compliance with the duty hour regulations.

  4. A comparison of choline:urea and choline:oxalic acid deep eutectic solvents at 338 K

    Science.gov (United States)

    Gilmore, Mark; Moura, Leila M.; Turner, Adam H.; Swadźba-Kwaśny, Małgorzata; Callear, Samantha K.; McCune, Jade A.; Scherman, Oren A.; Holbrey, John D.

    2018-05-01

    1:2 choline chloride:urea and 1:1 choline chloride:oxalic acid deep eutectic solvents are compared at 338 K using liquid-phase neutron diffraction with H/D isotopic substitution to obtain differential neutron scattering cross sections and fitting of models to the experimental data using Empirical Potential Structure Refinement. In comparison to the previously reported study of choline chloride:urea at 303 K, we observed significant weakening and lengthening of choline-OH⋯Cl- and choline-OH⋯hydrogen-bond acceptor correlations.

  5. Final report on CCM key comparison CCM.D-K2: Comparison of liquid density standards

    Science.gov (United States)

    Bettin, Horst; Jacques, Claude; Zelenka, Zoltán; Fujii, Ken-ichi; Kuramoto, Naoki; Chang, Kyung-Ho; Lee, Yong Jae; Becerra, Luis Omar; Domostroeva, Natalia

    2013-01-01

    The results are presented of the key comparison CCM.D-K2 that covered the density measurements of four liquids: the density of water at 20 °C, of pentadecane at 15 °C, 20 °C, 40 °C and 60°C, of tetrachloroethlyene at 5 °C and 20 °C and of a viscous oil at 20 °C. Seven national metrology institutes measured the densities at atmospheric pressure by hydrostatic weighing of solid density standards in the time interval from 27 April 2004 to 28 June 2004. Since the participants were asked not to include components for a possible drift or inhomogeneity of the liquid in their uncertainty budget, these uncertainty contributions are investigated for the final evaluation of the data. For this purpose, results of stability and homogeneity measurements of the pilot laboratory are used. The participants decided not to include a possible drift of the liquid's density since no significant drift could be detected, and the influence of the drift and its uncertainty are negligible. Similarly, the inhomogeneity of the water and pentadecane samples is not significant and has no influence on the evaluation. Thus, it was neglected. Only the inhomogeneities of tetrachloroethylene and of the viscous oil were significant. Consequently, they were included in the evaluation. With one or two exceptions, the results show good agreement among the participants. Only in the case of water are the results clearly discrepant. The key comparison reference values were calculated by the weighted mean (taking into account a small correlation between two participants) in the case of consistent results. Otherwise the Procedure B of Cox was used. The expanded uncertainties of all reference densities are below 1 × 10-5 in relative terms. This satisfies the needs of all customers who wish to calibrate or check liquid density measuring instruments such as oscillation-type density meters. The comparison fully supports the calibration measurement capabilities table in the BIPM key comparison database

  6. A 30 mK, 13.5 T scanning tunneling microscope with two independent tips

    Energy Technology Data Exchange (ETDEWEB)

    Roychowdhury, Anita [Laboratory for Physical Sciences, College Park, Maryland 20742 (United States); Center for Nanophysics and Advanced Materials, Department of Physics, University of Maryland, College Park, Maryland 20740 (United States); Gubrud, M. A.; Dana, R.; Dreyer, M. [Laboratory for Physical Sciences, College Park, Maryland 20742 (United States); Anderson, J. R.; Lobb, C. J.; Wellstood, F. C. [Center for Nanophysics and Advanced Materials, Department of Physics, University of Maryland, College Park, Maryland 20740 (United States)

    2014-04-15

    We describe the design, construction, and performance of an ultra-low temperature, high-field scanning tunneling microscope (STM) with two independent tips. The STM is mounted on a dilution refrigerator and operates at a base temperature of 30 mK with magnetic fields of up to 13.5 T. We focus on the design of the two-tip STM head, as well as the sample transfer mechanism, which allows in situ transfer from an ultra high vacuum preparation chamber while the STM is at 1.5 K. Other design details such as the vibration isolation and rf-filtered wiring are also described. Their effectiveness is demonstrated via spectral current noise characteristics and the root mean square roughness of atomic resolution images. The high-field capability is shown by the magnetic field dependence of the superconducting gap of Cu{sub x}Bi{sub 2}Se{sub 3}. Finally, we present images and spectroscopy taken with superconducting Nb tips with the refrigerator at 35 mK that indicate that the effective temperature of our tips/sample is approximately 184 mK, corresponding to an energy resolution of 16 μeV.

  7. A 30 mK, 13.5 T scanning tunneling microscope with two independent tips.

    Science.gov (United States)

    Roychowdhury, Anita; Gubrud, M A; Dana, R; Anderson, J R; Lobb, C J; Wellstood, F C; Dreyer, M

    2014-04-01

    We describe the design, construction, and performance of an ultra-low temperature, high-field scanning tunneling microscope (STM) with two independent tips. The STM is mounted on a dilution refrigerator and operates at a base temperature of 30 mK with magnetic fields of up to 13.5 T. We focus on the design of the two-tip STM head, as well as the sample transfer mechanism, which allows in situ transfer from an ultra high vacuum preparation chamber while the STM is at 1.5 K. Other design details such as the vibration isolation and rf-filtered wiring are also described. Their effectiveness is demonstrated via spectral current noise characteristics and the root mean square roughness of atomic resolution images. The high-field capability is shown by the magnetic field dependence of the superconducting gap of CuxBi2Se3. Finally, we present images and spectroscopy taken with superconducting Nb tips with the refrigerator at 35 mK that indicate that the effective temperature of our tips/sample is approximately 184 mK, corresponding to an energy resolution of 16 μeV.

  8. Comparison of GC-ICP-MS and HPLC-ICP-MS for species-specific isotope dilution analysis of tributyltin in sediment after accelerated solvent extraction

    International Nuclear Information System (INIS)

    Wahlen, Raimund; Wolff-Briche, Celine

    2003-01-01

    This study describes a direct comparison of GC and HPLC hyphenated to ICP-MS determination of tributyltin (TBT) in sediment by species-specific isotope dilution analysis (SS-IDMS). The certified reference sediment PACS-2 (NRC, Canada) and a candidate reference sediment (P-18/HIPA-1) were extracted using an accelerated solvent extraction (ASE) procedure. For comparison of GC and LC methods an older bottle of PACS-2 was used, whilst a fresh bottle was taken for demonstration of the accuracy of the methods. The data obtained show good agreement between both methods for both the PACS-2 sediment (LC-ICP-IDMS 828±87 ng g -1 TBT as Sn, GC-ICP-IDMS 848±39 ng g -1 TBT as Sn) and the P-18/ HIPA-1 sediment (LC-ICP-IDMS 78.0±9.7 ng g -1 TBT as Sn, GC-ICP-IDMS 79.2±3.8 ng g -1 TBT as Sn). The analysis by GC-ICP-IDMS offers a greater signal-to-noise ratio and hence a superior detection limit of 0.03 pg TBT as Sn, in the sediment extracts compared to HPLC-ICP-IDMS (3 pg TBT as Sn). A comparison of the uncertainties associated with both methods indicates superior precision of the GC approach. This is related to the better reproducibility of the peak integration, which affects the isotope ratio measurements used for IDMS. The accuracy of the ASE method combined with HPLC-ICP-IDMS was demonstrated during the international interlaboratory comparison P-18 organised by the Comite Consultatif pour la Quantite de Matiere (CCQM). The results obtained by GC-ICP-IDMS for a newly opened bottle of PACS-2 were 1087±77 ng g -1 Sn for DBT and 876±51 ng g -1 Sn for TBT (expanded uncertainties with a coverage factor of 2), which are in good agreement with the certified values of 1090±150 ng g -1 Sn and 980±130 ng g -1 Sn, respectively. (orig.)

  9. International købelov (CISG)

    DEFF Research Database (Denmark)

    Gomard, Bernhard; Henschel, René Franz

    Commentary in Danish on the 1980 United Nations Convention on the International Sale of Goods (CISG)......Commentary in Danish on the 1980 United Nations Convention on the International Sale of Goods (CISG)...

  10. Modeling of Combined Heat and Power Plant Based on a Multi-Stage Gasifier and Internal Combustion Engines of Various Power Outputs

    Science.gov (United States)

    Khudyakova, G. I.; Kozlov, A. N.; Svishchev, D. A.

    2017-11-01

    The paper is concerned with an integrated system of internal combustion engine and mini combined heat and power plant (ICE-CHP). The system is based on multi-stage wood biomass gasification. The use of producer gas in the system affects negatively the internal combustion engine performance and, therefore, reduces the efficiency of the ICE-CHP plant. A mathematical model of an internal combustion engine running on low-calorie producer gas was developed using an overview of Russian and foreign manufacturers of reciprocating units, that was made in the research. A thermal calculation was done for four-stroke gas engines of different rated power outputs (30, 100 and 250 kW), running on producer gas (CO2 - 10.2, CO - 45.8, N2 - 38.8%). Thermal calculation demonstrates that the engine exhaust gas temperature reaches 500 - 600°C at the rated power level and with the lower engine power, the temperature gets higher. For example, for an internal combustion engine power of 1000 kW the temperature of exhaust gases equals 400°C. A comparison of the efficiency of engine operation on natural gas and producer gas shows that with the use of producer gas the power output declines from 300 to 250 kWe. The reduction in the effective efficiency in this case makes up 2%. The measures are proposed to upgrade the internal combustion engine to enable it to run on low-calorie producer gas.

  11. Progress in Primary Acoustic Thermometry at NIST: 273 K to 505 K

    Science.gov (United States)

    Strouse, G. F.; Defibaugh, D. R.; Moldover, M. R.; Ripple, D. C.

    2003-09-01

    The NIST Acoustic Thermometer determines the thermodynamic temperature by measuring the speed of sound of argon in a spherical cavity. We obtained the thermodynamic temperature of three fixed points on the International Temperature Scale of 1990: the melting point of gallium [T(Ga) = 302.9146 K] and the freezing points of indium [T(In) = 429.7485 K] and tin [T(Sn) = 505.078 K]. The deviations of thermodynamic temperature from the ITS-90 defined temperatures are T - T90 = (4.7 ± 0.6) mK at T(Ga) , T - T90 = (8.8 ± 1.5) mK at T(In) , and T - T90 = (10.7 ± 3.0) mK at T(Sn) , where the uncertainties are for a coverage factor of k = 1. Our results at T(In) and T(Sn) reduce the uncertainty of T - T90 by a factor of two in this range. Both T - T90 at T(Ga) and the measured thermal expansion of the resonator between the triple point of water and T(Ga) are in excellent agreement with the 1992 determination at NIST. The dominant uncertainties in the present data come from frequency-dependent and time-dependent crosstalk between the electroacoustic transducers. We plan to reduce these uncertainties and extend this work to 800 K.

  12. 75 FR 6397 - AMC USA, Inc. v. International First Service S.A. a/k/a IFS S.A, its Agents, Affiliated, Related...

    Science.gov (United States)

    2010-02-09

    ... Service USA, Inc. a/k/a IFS USA, Inc. d/b/a Global Wine Logistics USA Inc. a/k/a GWL USA, Inc., and Global... Wine Logistics USA Inc. a/k/a GWL USA, Inc. (``GWL USA''); Anita McNeil; International First Service... FEDERAL MARITIME COMMISSION [Docket No. 10-01] AMC USA, Inc. v. International First Service S.A. a...

  13. Non-isolated 30 kW class arcjet PCU

    Science.gov (United States)

    Wong, See-Pok; Britt, Edward J.

    1994-03-01

    A 30 kW class arcjet Power Conditioning Unit, PCU, was built and tested during this Phase 2 SBIR contract. The PCU is an improved version of two previously developed PCU's. All of these units are 3-phase, 20 kHz buck regulators with current mode feed back to modulate the duty cycle to control the arcjet current at any selected operating point. The steady state control can assure arcjet stability despite the negative dynamic resistance of the arc discharge. The system also has a circuit to produce a high voltage start pulse to breakdown the gas and initiate the arc. The start pulse is formed by temporarily switching a short current path across the output terminals with a special solid state switching array. The switches then open rapidly, and the energy stored in the output inductors of the buck regulator produces a pulse of approximately 2500 V for approximately 500 nsec. The system was tested and modified until the transition to steady operation occurred after start up with a very small surge current overshoot. The system also can withstand a direct short circuit across the output without damage. The automatic feed back control simply reduces the duty cycle to hold the current at the set point. When the short is removed the full power output is immediately restored. This latest version arcjet PCU is conduction cooled to remove waste heat by conduction to the base plate. This unit is closer to flight a type of design than the previous functional bread boards. Waste heat is small because the PCU has a very high efficiency, 296 percent. The PCU was extensively tested with resistor loads to simulate operation with an arcjet. The unit was tested with ammonia arcjets at the Jet Propulsion Laboratory. Approximately 400 hours of testing were completed, with several starts. Many hours were also demonstrated with resistive loads.

  14. 30 January 2012 - Danish National Research Foundation Chairman of board K. Bock and University of Copenhagen Rector R. Hemmingsen visiting ATLAS underground experimental area, CERN Control Centre and ALICE underground experimental area, throughout accompanied by J. Dines Hansen and B. Svane Nielsen; signing the guest book with CERN Director for Research and Scientific Computing S. Bertolucci and Head of International Relations F. Pauss.

    CERN Document Server

    Jean-Claude Gadmer

    2012-01-01

    30 January 2012 - Danish National Research Foundation Chairman of board K. Bock and University of Copenhagen Rector R. Hemmingsen visiting ATLAS underground experimental area, CERN Control Centre and ALICE underground experimental area, throughout accompanied by J. Dines Hansen and B. Svane Nielsen; signing the guest book with CERN Director for Research and Scientific Computing S. Bertolucci and Head of International Relations F. Pauss.

  15. Report on NIM-NMC bilateral comparison: SPRT calibration comparison from -190°C to 420°C

    Science.gov (United States)

    Sun, Jianping; Ye, Shaochun; Wang, Li; Zhang, Jintao; Kho, Haoyuan

    2016-01-01

    A bilateral comparison of local realization of the International temperature scale of 1990 (ITS-90) between National Institute of Metrology (NIM) and National Metrology Centre (NMC) was carried out over the temperature range from -190°C to 420°C. It involved six fixed points including the argon triple point, the mercury triple point, the triple point of water, the melting point of gallium, the freezing point of tin and the freezing point of zinc. In 2009, NMC asked NIM to participate in a bilateral comparison to link the NMC results to the Consultative Committee for Thermometry Key comparison 3 (CCT-K3) and facilitate the NMC's Calibration and measurement capabilities (CMCs) submission. This comparison was agreed by NIM and Asia Pacific Metrology Programme (APMP) in 2009, and registered in the Key Comparison Database (KCDB) in 2010 as CCT-K3.2. NMC supplied two 25 Ω fused silica sheath standard platinum resistance thermometers (SPRTs) as traveling standards. One of them was used at the Ga, Sn and Zn fixed points, while the other one was used at the Ar and Hg fixed point. NMC measured them before and after NIM measurement. During the comparison, a criterion for the SPRT was set as the stability at the triple point of water to be less than 0.3 mK. The results for both laboratories are summarized. A proposal for linking the NMC's comparison results to CCT-K3 is presented. The difference between NMC and NIM and the difference between NMC and the CCT-K3 Average Reference Value (ARV) using NIM as a link are reported with expanded uncertainties at each measured fixed point. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Development of 20 kW input power coupler for 1.3 GHz ERL main linac. Component test at 30 kW IOT test stand

    International Nuclear Information System (INIS)

    Sakai, Hiroshi; Umemori, Kensei; Sakanaka, Shogo; Takahashi, Takeshi; Furuya, Takaaki; Shinoe, Kenji; Ishii, Atsushi; Nakamura, Norio; Sawamura, Masaru

    2009-01-01

    We started to develop an input coupler for a 1.3 GHz ERL superconducting cavity. Required input power is about 20 kW for the cavity acceleration field of 20 MV/m and the beam current of 100 mA in energy recovery operation. The input coupler is designed based on the STF-BL input coupler and some modifications are applied to the design for the CW 20 kW power operation. We fabricated input coupler components such as ceramic windows and bellows and carried out the high-power test of the components by using a 30 kW IOT power source and a test stand constructed for the highpower test. In this report, we mainly describe the results of the high-power test of ceramic window and bellows. (author)

  17. A comparison of creatinine concentration with 40K radioactivity in spot urine

    International Nuclear Information System (INIS)

    Yoo, Jaeryong; Park, Minjeong; Park, Seyoung; Ha, Wiho; Lee, Seungsook; Kim, Kwangpyo; Yoo, Jaeryong; Park, Minjeong

    2013-01-01

    24 hour urine collection is technically difficult to carry out and inconvenience for subjects. Also the result of 24 hour urine may vary from collection date. The spot urine assessment has large uncertainty that some spot urine concentrated or some spot urine diluted. Hence, it needs to apply normalization method for minimizing result of measurement the spot urine. In radiation emergency, specific gravity method was proposed which method use portable density meter for measuring density of urine and then normalization. The creatinine test recommend by ICRP (1968) and IAEA (1999) is the most common method for urine normalization. However, the creatinine result was various which depends upon sex, age, race and health conditions. Thus it needs to supplementary method for urine normalization. Natural potassium has isotopes those are K-39, K-40, and K-41, in the percentages of 93.08, 0.0118 and 6.91, respectively. Especially, the K-40 emits relatively high energy (1.46 MeV gamma ray) with a half life of 1.248 Χ 10 9 γ. The potassium is an essential element in human which works as homeostatic regulation. Thus human which works as homeostatic regulation. Thus human which works as homeostatic regulation. Thus human body contains specific amount of the potassium and then excreted regularly. And then K-40 is measurable in urine sample using HPGs detector. The purpose of this study is to estimate the variability of spot urine normalization method for assessing the internal exposure dose of hospital workers who work related with radiopharmaceutical produce. The use of creatinine as normalization of spot urine samples for internal dosimetry is possible to reduce level of uncertainty. However, creatinine range is wide which means the creatinine is not exactly correct reference value for normalization. Or some malfunction in creatinine analysis, it need to another supplementary method for normalization for adequately assessing the activity in spot urine samples. In this study

  18. Correlation between in-field critical currents in Zr-added (Gd, Y)Ba2Cu3Ox superconducting tapes at 30 and 77 K

    International Nuclear Information System (INIS)

    Selvamanickam, V; Xu, A; Liu, Y; Khatri, N D; Galstyan, E; Majkic, G; Lei, C; Chen, Y

    2014-01-01

    Critical current (I c ) values of 1384 A/12 mm, corresponding to a critical current density of 12.47 MA cm −2 and a pinning force of 374 GN m −3 , have been achieved at 30 K, 3 T in the orientation of field parallel to the c axis (B ∥ c) in (Gd, Y)BaCuO tapes with 15 mol% Zr addition made by metal organic chemical vapor deposition (MOCVD). These tapes show pinning force levels as high as 453 GN m −3 at 30 K. An analysis of the properties of 24–28 (Gd, Y)BaCuO tapes with 15 mol% Zr addition showed a lack of correlation between their critical currents at 30 K, 3 T (B ∥ c) and I c values both at 77 K, zero field and at 77 K, 1 T (B ∥ c). However, a strong correlation was found between the critical currents at 30 K, 3 T and at 77 K, 3 T (B ∥ c). It has also been discovered that the minimum critical current (I c, min ) value at 77 K, 3 T has no influence on the I c, min value at 30 K, 3 T, and it in turn depends on the ratio of the I c values in the orientations of field parallel and perpendicular to the c axis at 77 K, 3 T. (paper)

  19. An Experimental Study of the Decay $D^0 \\to K^- K^- K^+ \\pi^+$

    Energy Technology Data Exchange (ETDEWEB)

    Devmal, Shiral Cleophas [Cincinnati U.

    2000-05-01

    Using data from the E791 experiment at Fermi National Accelerator Laboratory (Fermilab), we have studied the Cabibbo favored, but phase space suppressed decay $D^0 \\to K^-K^- K^+ \\pi^+$ with the normalization channel $D^0 \\to K^- \\pi^- \\pi^+ \\pi^+$. We report the branching ratio of $D^0 \\to K^- K^- K^+ \\pi^+$ relative to the branching ratio of $D^0 \\to K^- \\pi^- \\pi^+ \\pi^+$. This value is (0.54 $\\pm$ 0.13 $\\pm$ 0.07)%. We see a clear signal of $K^-K^+$ resonance in the decay $D^0 \\to K^-K^-K^+\\pi^+$ from which we conclude that about (60 $\\pm$ 30)% of $KKK\\pi$ comes from $D^0 \\to \\phi K^-\\pi^+; \\phi \\to K^-K^+$. We also set the range (0.30% - 0.90%) for the ratio $P_{q\\overline{q}} = P_{NoPop}$ where $P_{q\\bar{q}}$ is the contribution from either $D^0 \\to K^-K^-K^+\\pi^+$ terms that pop an $s\\bar{s}$ or corresponding $D^0 \\to K^- \\pi^- \\pi^+ \\pi^+$ terms that pop either $u\\bar{u}$ or $d\\bar{d}$ pair and $P_{NoPop}$ is the contributions from the $D^0 \\to K^- \\pi^- \\pi^+ \\pi^+$ terms that do not have such corresponding popping.

  20. KEY COMPARISON Bilateral comparison of 1.018 V and 10 V standards between the NSAI-NML (Ireland) and the BIPM, March to April 2010 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    Science.gov (United States)

    Power, O.; Solve, S.; Chayramy, R.; Stock, M.

    2010-01-01

    As a part of the ongoing BIPM key comparisons BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and of the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from March to April 2010. Two BIPM Zener diode-based travelling standards were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage is maintained at the 10 V level by means of a group of characterized Zener diode-based electronic voltage standards. The output EMF of each travelling standard, at the 10 V output terminals, was measured by direct comparison with the group standard. Measurements of the output EMF of the travelling standards at the 1.018 V output terminals were made using a potentiometer, standardized against the local 10 V reference standard. At the BIPM, the travelling standards were calibrated at both voltages before and after the measurements at NSAI-NML, using the BIPM Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages on internal temperature and ambient pressure. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated expanded uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  1. COOMET pilot comparison 473/RU-a/09: Comparison of hydrophone calibrations in the frequency range 250 Hz to 200 kHz

    Science.gov (United States)

    Yi, Chen; Isaev, A. E.; Yuebing, Wang; Enyakov, A. M.; Teng, Fei; Matveev, A. N.

    2011-01-01

    A description is given of the COOMET project 473/RU-a/09: a pilot comparison of hydrophone calibrations at frequencies from 250 Hz to 200 kHz between Hangzhou Applied Acoustics Research Institute (HAARI, China)—pilot laboratory—and Russian National Research Institute for Physicotechnical and Radio Engineering Measurements (VNIIFTRI, Designated Institute of Russia of the CIPM MRA). Two standard hydrophones, B&K 8104 and TC 4033, were calibrated and compared to assess the current state of hydrophone calibration of HAARI (China) and Russia. Three different calibration methods were applied: a vibrating column method, a free-field reciprocity method and a comparison method. The standard facilities of each laboratory were used, and three different sound fields were applied: pressure field, free-field and reverberant field. The maximum deviation of the sensitivities of two hydrophones between the participants' results was 0.36 dB. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCAUV-KCWG.

  2. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, March 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    Science.gov (United States)

    Solve, S.; Chayramy, R.; Power, O.; Stock, M.

    2014-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out in February and March 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_4 (Z4) and BIPM_5 (Z5), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 10 March 2014. UNML - UBIPM = -0.64 µV uc = 1.35 µV, at 10 V where uc is thecombined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML,based on KJ-90, and the uncertainty related to the comparison. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to

  3. Bilateral Comparison of 10 V Standards between the NSAI - NML (Ireland) and the BIPM, March 2015 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    Science.gov (United States)

    Solve, S.; Chayramy, R.; Stock, M.; Power, O.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland - National Metrology Laboratory (NSAI - NML), Dublin, Ireland, was carried out in February and March 2015. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM6 (Z6) and BIPMC (ZC), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final resultof the comparison is presented as the difference between the values assigned to DC voltage standards by NSAI - NML, at the level of 10 V,at NSAI - NML, UNML, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 24 February 2015. UNML - UBIPM = - 0.82 mV; uc = 1.35 mV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Bilateral comparison of 10 V standards between the NSAI - NML (Ireland) and the BIPM, February 2016 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    Science.gov (United States)

    Solve, S.; Chayramy, R.; Power, O.; Stock, M.

    2016-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland - National Metrology Laboratory (NSAI - NML), Dublin, Ireland, was carried out in January and February 2016. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM7 (Z7) and BIPM9 (Z9), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NSAI - NML, at the level of 10 V, at NSAI - NML, UNML, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 31 of January 2016. UNML - UBIPM = + 0.22 μV uc = 1.35 μV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Can the Apgar Score be Used for International Comparisons of Newborn Health?

    NARCIS (Netherlands)

    Siddiqui, A.; Cuttini, M.; Wood, R.; Velebil, P.; Delnord, M.; Zile, I.; Barros, H.; Gissler, M.; Hindori-Mohangoo, A.D.; Blondel, B.; Zeitlin, J.; Euro-Peristat Scientific Committee; Haidinger, G.; Alexander, S.; Pavlou, P.; Mortensen, L.; Sakkeus, L.; Lack, N.; Antsaklis, A.; Berbik, I.; Ólafsdóttir, H.S.; Bonham, S.; Misins, J.; Jaselioniene, J.; Wagener, Y.; Gatt, M.; Nijhuis, J.; Klungsøyr, K.; Szamotulska, K.; Horga, M.; Cap, J.; Mandić, N.T.; Bolúmar, F.; Gottvall, K.; Berrut, S.; Macfarlane, A.

    2017-01-01

    Background: The Apgar score has been shown to be predictive of neonatal mortality in clinical and population studies, but has not been used for international comparisons. We examined population-level distributions in Apgar scores and associations with neonatal mortality in Europe. Methods: Aggregate

  6. First international 26Al interlaboratory comparison - Part II

    International Nuclear Information System (INIS)

    Merchel, Silke; Bremser, Wolfram

    2005-01-01

    After finishing Part I of the first international 26 Al interlaboratory comparison with accelerator mass spectrometry (AMS) laboratories [S. Merchel, W. Bremser, Nucl. Instr. and Meth. B 223-224 (2004) 393], the evaluation of Part II with radionuclide counting laboratories took place. The evaluation of the results of the seven participating laboratories on four meteorite samples shows a good overall agreement between laboratories, i.e. it does not reveal any statistically significant differences if results are compared sample-by-sample. However, certain interlaboratory bias is observed with a more detailed statistical analysis including some multivariate approaches

  7. Progress in Noise Thermometry at 505 K and 693 K Using Quantized Voltage Noise Ratio Spectra

    Science.gov (United States)

    Tew, W. L.; Benz, S. P.; Dresselhaus, P. D.; Coakley, K. J.; Rogalla, H.; White, D. R.; Labenski, J. R.

    2010-09-01

    Technical advances and new results in noise thermometry at temperatures near the tin freezing point and the zinc freezing point using a quantized voltage noise source (QVNS) are reported. The temperatures are derived by comparing the power spectral density of QVNS synthesized noise with that of Johnson noise from a known resistance at both 505 K and 693 K. Reference noise is digitally synthesized so that the average power spectra of the QVNS match those of the thermal noise, resulting in ratios of power spectra close to unity in the low-frequency limit. Three-parameter models are used to account for differences in impedance-related time constants in the spectra. Direct comparison of noise temperatures to the International Temperature Scale of 1990 (ITS-90) is achieved in a comparison furnace with standard platinum resistance thermometers. The observed noise temperatures determined by operating the noise thermometer in both absolute and relative modes, and related statistics together with estimated uncertainties are reported. The relative noise thermometry results are combined with results from other thermodynamic determinations at temperatures near the tin freezing point to calculate a value of T - T 90 = +4(18) mK for temperatures near the zinc freezing point. These latest results achieve a lower uncertainty than that of our earlier efforts. The present value of T - T 90 is compared to other published determinations from noise thermometry and other methods.

  8. Comparison of the reactions $K^{\\pm} p \\rightarrow Q^{\\pm} p$ at incident momentum 8.25 GeV/c

    CERN Document Server

    Stergiou, Athanase; Dallman, David Peter; Drijard, Daniel; Dunwoodie, W M; Fry, John R; Goldschmidt-Clermont, Yves; Grard, F; Henri, Victor P; Heughebaert, J; Markytan, Manfred; Matthews, Robert; Michaelidis, P; Muirhead, William Hugh; Peeters, P; Quinquard, J; Simopoulou, Errietta; Sotiriou, D; Strauss, Josef; Tsilimigras, Panayiotis; Vayaki, Anna; Verbeure, Frans; Windmolders, R

    1976-01-01

    A comparison of the general features of the reactions K/sup +or-/P to Q/sup +or-/p at incident momentum 8.25 GeV/c is presented. The relevant data derive from events yielding four-constraint fits to the reactions K/sup +or-/p to K/sup +or-/ pi /sup +/ pi /sup -/p in exposures of the CERN 2 m HBC to RF-separated K/sup +/ and K/sup -/ beams. The (K pi pi ) effective mass distributions, producing angular distributions in the Q region (1.2K pi pi )

  9. Translation and Adaptation of Tests: Lessons Learned and Recommendations for Countries Participating in timss, pisa and other International Comparisons

    Directory of Open Access Journals (Sweden)

    Guillermo Solano-Flores

    2006-11-01

    Full Text Available In this paper we present a conceptual model and methodology for the review of translated tests in the context of such international comparisons as the Trends in International Mathematics and Science Study (TIMSS and the Programme for International Student Assessment (PISA. We also present the results of an investigation into the quality of the Mexican translation of the TIMSS-1995 into the Spanish language. We identified translation errors in a significant percentage of the items, as well as relatively high correlations between the severity of translation errors and the items’ p-values. These findings indicate that our error-coding system is highly sensitive to test-translation error. The results underscore the need for improved translation and translation-review procedures in international comparisons. In our opinion, to implement the guidelines properly for test translation in international comparisons, each participating country needs to have internal procedures that would ensure a rigorous review of its own translations. The article concludes with four recommendations for countries participating in international comparisons. These recommendations relate to: (a the characteristics of the individuals in charge of translating instruments; (b the use of review, not simply at the end of the process, but during the process of test translation; (c the minimum time needed for various translation review iterations to take place; and (d the need for proper documentation of the entire process of test translation.

  10. Enhanced Oxygen Diffusion Within the Internal Oxidation Zone of Alloy 617 in Controlled Impurity Helium Environments from 1023 K to 1123 K (750 °C to 850 °C)

    Science.gov (United States)

    Gulsoy, Gokce; Was, Gary S.

    2015-04-01

    Alloy 617 was exposed to He-CO-CO2 environments with of either 9 or 1320 at temperatures from 1023 K to 1123 K (750 °C to 850 °C) to determine the oxygen diffusion coefficients within the internal oxidation zone of the alloy. The oxygen diffusion coefficients determined based on both intergranular and transgranular oxidation rates were several orders of magnitude greater than those reported in pure nickel and in nickel-based binary alloys, indicating that the rapid internal aluminum oxidation of Alloy 617 was primarily due to enhanced oxygen diffusion along the incoherent Al2O3-alloy interfaces. The range of activation energy values determined for oxygen diffusion associated with the intergranular aluminum oxidation was from 149.6 to 154.7 kJ/mol, and that associated with the transgranular aluminum oxidation was from 244.7 to 283.5 kJ/mol.

  11. Recursion method in the k-space representation

    International Nuclear Information System (INIS)

    Anlage, S.M.; Smith, D.L.

    1986-01-01

    We show that by using a unitary transformation to k space and the special-k-point method for evaluating Brillouin-zone sums, the recursion method can be very effectively applied to translationally invariant systems. We use this approach to perform recursion calculations for realistic tight-binding Hamiltonians which describe diamond- and zinc-blende-structure semiconductors. Projected densities of states for these Hamiltonians have band gaps and internal van Hove singularities. We calculate coefficients for 63 recursion levels exactly and for about 200 recursion levels to a good approximation. Comparisons are made for materials with different magnitude band gaps (diamond, Si, α-Sn). Comparison is also made between materials with one (e.g., diamond) and two (e.g., GaAs) band gaps. The asymptotic behavior of the recursion coefficients is studied by Fourier analysis. Band gaps in the projected density of states dominate the asymptotic behavior. Perturbation analysis describes the asymptotic behavior rather well. Projected densities of states are calculated using a very simple termination scheme. These densities of states compare favorably with the results of Gilat-Raubenheimer integration

  12. Senescence marker protein 30 (SMP30 expression in eukaryotic cells: existence of multiple species and membrane localization.

    Directory of Open Access Journals (Sweden)

    Peethambaran Arun

    Full Text Available Senescence marker protein (SMP30, also known as regucalcin, is a 34 kDa cytosolic marker protein of aging which plays an important role in intracellular Ca(2+ homeostasis, ascorbic acid biosynthesis, oxidative stress, and detoxification of chemical warfare nerve agents. In our goal to investigate the activity of SMP30 for the detoxification of nerve agents, we have produced a recombinant adenovirus expressing human SMP30 as a fusion protein with a hemaglutinin tag (Ad-SMP30-HA. Ad-SMP30-HA transduced the expression of SMP30-HA and two additional forms of SMP30 with molecular sizes ∼28 kDa and 24 kDa in HEK-293A and C3A liver cells in a dose and time-dependent manner. Intravenous administration of Ad-SMP30-HA in mice results in the expression of all the three forms of SMP30 in the liver and diaphragm. LC-MS/MS results confirmed that the lower molecular weight 28 kDa and 24 kDa proteins are related to the 34 kDa SMP30. The 28 kDa and 24 kDa SMP30 forms were also detected in normal rat liver and mice injected with Ad-SMP30-HA suggesting that SMP30 does exist in multiple forms under physiological conditions. Time course experiments in both cell lines suggest that the 28 kDa and 24 kDa SMP30 forms are likely generated from the 34 kDa SMP30. Interestingly, the 28 kDa and 24 kDa SMP30 forms appeared initially in the cytosol and shifted to the particulate fraction. Studies using small molecule inhibitors of proteolytic pathways revealed the potential involvement of β and γ-secretases but not calpains, lysosomal proteases, proteasome and caspases. This is the first report describing the existence of multiple forms of SMP30, their preferential distribution to membranes and their generation through proteolysis possibly mediated by secretase enzymes.

  13. KEY COMPARISON Report to the CCT on key comparison EUROMET.T-K6 (EUROMET Project no. 621): Comparison of the realizations of local dew/frost-point temperature scales in the range -50 °C to +20 °C

    Science.gov (United States)

    Heinonen, Martti

    2010-01-01

    The first humidity CIPM key comparison, CCT-K6, will be completed in 2010. The corresponding European regional key comparison, EUROMET.T-K6, was carried out in 2004 to 2008. National metrology institutes from 24 countries participated in the comparison. The comparison covered the dew-point temperature range from -50 °C to +20 °C. It was organized as three parallel loops with two specially manufactured precision chilled mirror hygrometers as transfer standards in each loop. The comparison scheme was designed to ensure high quality results with evenly spread workload for the participants. MIKES was coordinating the project. This report presents the results of the comparison and provides detailed information on the measurements performed by all participating laboratories and the analysis of the results. Conclusions on the equivalence of the dew-point temperature standards are drawn on the basis of calculated bilateral degrees of equivalence and deviations from EURAMET comparison reference values (ERV). Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  14. An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV.

    Science.gov (United States)

    Boone, J M; Seibert, J A

    1997-11-01

    A tungsten anode spectral model using interpolating polynomials (TASMIP) was used to compute x-ray spectra at 1 keV intervals over the range from 30 kV to 140 kV. The TASMIP is not semi-empirical and uses no physical assumptions regarding x-ray production, but rather interpolates measured constant potential x-ray spectra published by Fewell et al. [Handbook of Computed Tomography X-ray Spectra (U.S. Government Printing Office, Washington, D.C., 1981)]. X-ray output measurements (mR/mAs measured at 1 m) were made on a calibrated constant potential generator in our laboratory from 50 kV to 124 kV, and with 0-5 mm added aluminum filtration. The Fewell spectra were slightly modified (numerically hardened) and normalized based on the attenuation and output characteristics of a constant potential generator and metal-insert x-ray tube in our laboratory. Then, using the modified Fewell spectra of different kVs, the photon fluence phi at each 1 keV energy bin (E) over energies from 10 keV to 140 keV was characterized using polynomial functions of the form phi (E) = a0[E] + a1[E] kV + a2[E] kV2 + ... + a(n)[E] kVn. A total of 131 polynomial functions were used to calculate accurate x-ray spectra, each function requiring between two and four terms. The resulting TASMIP algorithm produced x-ray spectra that match both the quality and quantity characteristics of the x-ray system in our laboratory. For photon fluences above 10% of the peak fluence in the spectrum, the average percent difference (and standard deviation) between the modified Fewell spectra and the TASMIP photon fluence was -1.43% (3.8%) for the 50 kV spectrum, -0.89% (1.37%) for the 70 kV spectrum, and for the 80, 90, 100, 110, 120, 130 and 140 kV spectra, the mean differences between spectra were all less than 0.20% and the standard deviations were less than approximately 1.1%. The model was also extended to include the effects of generator-induced kV ripple. Finally, the x-ray photon fluence in the units of

  15. PI3K/Akt Activated by GPR30 and Src Regulates 17β-Estradiol-Induced Cultured Immature Boar Sertoli Cells Proliferation.

    Science.gov (United States)

    Yang, Wei-Rong; Zhu, Feng-Wei; Zhang, Jiao-Jiao; Wang, Yi; Zhang, Jia-Hua; Lu, Cheng; Wang, Xian-Zhong

    2016-05-24

    Sertoli cell (SC) is a key element in the process of spermatogenesis. Accumulating research show that estrogen plays an important role in regulating boar SC proliferation. However, it is unclear whether phosphatidylinositol-4,5-bisphosphate 3-kinase/protein kinase B (PI3K/Akt) is involved in this process. In the present study, the role of PI3K/Akt on the 17β-estradiol-induced piglet SC proliferation was explored. In addition, we also explained the roles of G-protein-coupled estrogen receptor (GPR30) and Sarcoma protein (Src) in this process. Our study demonstrated that, 17β-estradiol induced activation of PI3K in a time-dependent manner. Both G-15 (an antagonist of GPR30, 0.1 μmol/L) and PP2 (an inhibitor of Src, 2.0 μmol/L) inhibited 17β-estradiol-induced activation of PI3K, reduced SC proliferation, and decreased messenger RNA (mRNA) and protein expression of S-phase kinase-associated protein 2 (Skp2). We also found that 17β-estradiol induced activation of Akt in a time-dependent manner. Both LY294002 (an inhibitor of PI3K) and 10-DEBC (an inhibitor of Akt) significantly reduced 17β-estradiol-induced SC proliferation and reduced mRNA and protein expression of Skp2. In addition, LY294002 inhibited 17β-estradiol-induced activation of Akt. The results indicated that 17β-estradiol regulates SC proliferation by activating PI3K/Akt. Both GPR30 and Src are involved in 17β-estradiol-induced phosphorylation of PI3K/Akt. Activation of PI3K/Akt enhances the expression of Skp2, which promotes SC proliferation. © The Author(s) 2016.

  16. THE CCAUV.A-K3 KEY COMPARISON OF PRESSURE RECIPROCITY CALIBRATION OF LS2P MICROPHONES: RESULTS AND ANALYSIS

    DEFF Research Database (Denmark)

    Cutanda Henríquez, Vicente; Rasmussen, Knud; Nielsen, Lars

    2006-01-01

    The CCAUV.A-K3 Key Comparison has involved 15 countries organized in two loops with two common laboratories, CENAM and DPLA. The measurements took place in 2003. This is the first CCAUV key comparison organized with more than one loop, and therefore the analysis of the results required a more ela...

  17. Mitogen-Activated Protein Kinase 8 (MAP3K8) Mediates the Signaling Pathway of Estradiol Stimulating Progesterone Production Through G Protein-Coupled Receptor 30 (GPR30) in Mouse Corpus Luteum.

    Science.gov (United States)

    Liu, Ying; Li, Yueqin; Zhang, Di; Liu, Jiali; Gou, Kemian; Cui, Sheng

    2015-05-01

    The corpus luteum (CL) is a transient endocrine gland developed from the ovulated follicles, and the most important function is to synthesize and secrete progesterone (P(4)), a key hormone to maintain normal pregnancy and estrous cycle in most mammals. It is known that estrogen has a vital role in stimulating P(4) synthesis in CL, but it still remains unclear about the mechanism of estradiol (E(2)) regulating P(4) production in CL. Our results here first show that all of the CL cells express MAPK 8 (MAP3K8), and the MAP3K8 level is much higher at the midstage than at the early and late stages during CL development. The further functional studies show that the forced inhibition of endogenous MAP3K8 by using MAP3K8 small interfering RNA and MAP3K8 signaling inhibitor (MAP3K8i) in the luteal cells significantly block the P(4) synthesis and neutralize the enhancing effect of E(2) on P(4) production in the CL. In addition, our results here demonstrate that the stimulating effect of E(2) on P(4) synthesis relies on the estrogen no-classical protein-coupled receptor 30, and MAP3K8 is involved in mediating the protein-coupled receptor 30signaling of E(2) affecting P(4) synthesis via stimulating ERK phosphorylation. These novel findings are critical for our understanding the ovary physiology and pathological mechanism.

  18. International comparison of methods to test the validity of dead-time and pile-up corrections for high-precision. gamma. -ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Houtermans, H.; Schaerf, K.; Reichel, F. (International Atomic Energy Agency, Vienna (Austria)); Debertin, K. (Physikalisch-Technische Bundesanstalt, Braunschweig (Germany, F.R.))

    1983-02-01

    The International Atomic Energy Agency organized an international comparison of methods applied in high-precision ..gamma..-ray spectrometry for the correction of dead-time and pile-up losses. Results of this comparison are reported and discussed.

  19. Effects of electric fields on membrane-bound Na, K-ATPase. Progress report, 1 July 1989-30 June 1990

    Energy Technology Data Exchange (ETDEWEB)

    Tsong, T.Y.

    1990-06-30

    We continued to work on effects of oscillating electric fields on membrane functions, in particular the electric activation of Na, K-ATPase, and to develop theory of electro-conformational coupling. We believe transmembrane electric fields are involved in the regulation of the internal activity of a cell and also in the cell-to-cell communications. An in depth study of Na, K-ATPase will provide useful information concerning the molecular design of a cell to sense and to transmit signals.

  20. 26 CFR 1.168(k)-1 - Additional first year depreciation deduction.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Additional first year depreciation deduction. 1... Corporations § 1.168(k)-1 Additional first year depreciation deduction. (a) Scope and definitions—(1) Scope. This section provides the rules for determining the 30-percent additional first year depreciation...

  1. Factors associated with intern noncompliance with the 2003 Accreditation Council for Graduate Medical Education’s 30-hour duty period requirement

    Directory of Open Access Journals (Sweden)

    Maloney Christopher G

    2012-07-01

    Full Text Available Abstract Background In 2003 the Accreditation Council for Graduate Medical Education mandated work hour restrictions. Violations can results in a residency program being cited or placed on probation. Recurrent violations could results in loss of accreditation. We wanted to determine specific intern and workload factors associated with violation of a specific mandate, the 30-hour duty period requirement. Methods Retrospective review of interns’ performance against the 30-hour duty period requirement during inpatient ward rotations at a pediatric residency program between June 24, 2008 and June 23, 2009. The analytical plan included both univariate and multivariable logistic regression analyses. Results Twenty of the 26 (77% interns had 80 self-reported episodes of continuous work hours greater than 30 hours. In multivariable analysis, noncompliance was inversely associated with the number of prior inpatient rotations (odds ratio: 0.49, 95% confidence interval (0.38, 0.64 per rotation but directly associated with the total number of patients (odds ratio: 1.30 (1.10, 1.53 per additional patient. The number of admissions on-call, number of admissions after midnight and number of discharges post-call were not significantly associated with noncompliance. The level of noncompliance also varied significantly between interns after accounting for intern experience and workload factors. Subject to limitations in statistical power, we were unable to identify specific intern characteristics, such as demographic variables or examination scores, which account for the variation in noncompliance between interns. Conclusions Both intern and workload factors were associated with pediatric intern noncompliance with the 30-hour duty period requirement during inpatient ward rotations. Residency programs must develop information systems to understand the individual and experience factors associated with noncompliance and implement appropriate interventions to

  2. [Case control study on therapeutic effects of dynamic external fixtor combined with limited internal fixation and cross K-wires fixation for the treatment of Pilon fractures of the proximal interphalangeal joint].

    Science.gov (United States)

    Miao, Dao-yi; Yang, Guo-jing; Zhang, Ling-zhou; Wu, Jian-wei

    2015-10-01

    To compare the clinical effects and safety of dynamic external fixtor combined with limited internal fixation and cross K-wires fixation for the treatment of close Pilon fractures of the proximal interphalangeal joint. From June 2012 to June 2014, totally 41 patients (45 fingers) with close interphalangeal joint Pilon fracture were treated by dynamic external fixtor combined with limited internal fixation or cross K-wires fixation, and all the patients were followed up. In the dynamic external fixtor combined with limited internal fixation group (group A), there were 21 patients with 22 fingers, including 12 males and 9 females, with an average of (30.6±5.6) years old. In the cross K-wires fixation group (group B), there were 20 patients with 23 fingers, including 11 males and 9 females, with an average of (30.1±5.3) years old. Regular re-examination of X-ray was performed to evaluate the active range of joint motion, fracture healing time, infection rate and postoperative joint motion pain. According to the evaluation criteria of upper extremity function issued by the Hand Surgery Society of Chinese Medical Association, the excellent and good cases of group A was up to 19 and 13 for group B. The evaluation results has significant differences (Z=2.558, P=0.011). The excellent and good rate of group A was obviously higher than that of group B. The average bone union time of group A was (7.9±2.1) weeks, and (8.1±2.3) weeks for group B. There was no significant difference on the mean healing time (t=-0.304, P=0.762). The infection fingers of group A was 5, and 1 for group B. The difference between the results was statistically significant (χ2=3.287, Pexternal fixtor combined with limited internal fixation is a reliable and effective method to treat Pilon fractures of the proximal interphalangeal joint. It allows early postoperative functional rehabilitation and restores the joint function.

  3. Vitamin K Acupuncture Point Injection for Severe Primary Dysmenorrhea: An International Pilot Study

    Science.gov (United States)

    Wang, Li; Zhao, Wenjie; Yu, Jin; Cardini, Francesco; Forcella, Emanuela; Regalia, Anna Laura; Wade, Christine

    2004-01-01

    Context Vitamin K acupuncture point injection, a menstrual pain treatment derived from traditional Chinese medicine, has been a standard treatment in some hospitals in China since the 1980s. Objectives To investigate the effects of vitamin K acupuncture point injection on menstrual pain in young women aged 14 to 25 from different countries and cultural backgrounds who have had unmitigated severe primary dysmenorrhea for 6 months or more Design Prospective, observational, clinical pilot study Settings One site in China (a hospital outpatient clinic in Shanghai) and 2 sites in Italy (a hospital clinic in Milan and a private gynecology practice in Verona) Interventions All subjects were treated with bilateral acupuncture point injection of vitamin K on the first or second day of menstrual pain. Vitamin K3 was used in China and vitamin K4 in Italy. Main Outcome Measures Pain intensity, total duration, and average intensity of menstrual distress, hours in bed, normal daily activity restrictions, and numbers of analgesic tablets taken to relieve pain were recorded before the treatment and for 4 subsequent menstrual cycles. Results Noticeable pain relief was observed 2 minutes after treatment, and subsequent pain reduction occurred at 30 minutes (P vitamin K alleviated acute menstrual pain, and relief extended through the nontreatment follow-up cycles in this uncontrolled pilot study conducted in 2 countries. Further investigation employing controlled experimental designs is warranted. PMID:15775872

  4. DC resistance comparison between a current comparator bridge and the quantum Hall system at Inmetro

    International Nuclear Information System (INIS)

    Da Silva, M C; Vasconcellos, R T B; Carvalho, H R

    2016-01-01

    This paper presents a comparison results between the Quantum Hall System (QHS) under development at the Quantum Electrical Metrology Laboratory (Lameq) and the current comparator calibration system, traceable to the Bureau International des Poids et Mesures (BIPM), at the Electrical Standardization Metrology Laboratory (Lampe), both part of the Electrical Metrology Division, at Inmetro. Comparisons were performed with 1 Ω, 10 Ω, 100 Ω, 1 kΩ and 10 kΩ resistors. The results obtained over two years of work are presented here, showing that the comparison contributed to improve the calibration systems of both Lampe and Lameq. (paper)

  5. Charge exchange K-tau scattering in the small Vertical BartVertical Bar range at momemtum 30 GeV/c

    International Nuclear Information System (INIS)

    Binon, F.; Gouanere, M.; Davydov, V.A.; Donskov, S.V.; Duteil, P.; Dufournaud, J.; Inayakin, A.V.; Kakauridze, D.B.; Kachanov, V.A.; Kulik, A.V.; Lagnaux, J.P.; Lednev, A.A.; Maisheev, V.A.; Mel'nik, Y.M.; Mikhailov, Y.V.; Peigneux, J.P.; Prokoshkin, Y.D.; Rodnov, Y.V.; Roosen, R.; Startsev, A.V.; Stroot, J.P.; Khaustov, G.V.

    1981-01-01

    Differential cross sections for the reaction K - p→K-bar 0 n at momentum 30 GeV/c have been measured with high angular resolution and statistical accuracy. The experiments were performed at the 70-GeV Serpukhov accelerator using a hodoscopic hadron calorimeter which recorded K 0 /sub L/ mesons. The t-dependence of the cross section shows a marked drop at small Vertical BartVertical Bar which corresponds to a dominant contribution from spin-flip in the rho- and A 2 -exchange amplitudes in the t-channel

  6. Seafloor multibeam backscatter calibration experiment: comparing 45°-tilted 38-kHz split-beam echosounder and 30-kHz multibeam data

    Science.gov (United States)

    Ladroit, Yoann; Lamarche, Geoffroy; Pallentin, Arne

    2018-06-01

    Obtaining absolute seafloor backscatter measurements from hydrographic multibeam echosounders is yet to be achieved. We propose a low-cost experiment to calibrate the various acquisition modes of a 30-kHz Kongsberg EM 302 multibeam echosounder in a range of water depths. We use a 38-kHz Simrad EK60 calibrated fisheries split-beam echosounder mounted at 45° angle on the vessel's hull as a reference for the calibration. The processing to extract seafloor backscatter from the EK60 requires bottom detection, ray tracing and motion compensation to obtain acceptable geo-referenced backscatter measurements from this non-hydrographic system. Our experiment was run in Cook Strait, New Zealand, on well-known seafloor patches in shallow, mid, and deep-water depths. Despite acquisition issues due to weather, our results demonstrate the strong potential of such an approach to obtain system's absolute calibration which is required for quantitative use of backscatter strength data.

  7. A comparison of creatinine concentration with {sup 40}K radioactivity in spot urine

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Jaeryong; Park, Minjeong; Park, Seyoung; Ha, Wiho; Lee, Seungsook [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Kim, Kwangpyo; Yoo, Jaeryong; Park, Minjeong [Kyung Hee Univ., Yongin (Korea, Republic of)

    2013-05-15

    24 hour urine collection is technically difficult to carry out and inconvenience for subjects. Also the result of 24 hour urine may vary from collection date. The spot urine assessment has large uncertainty that some spot urine concentrated or some spot urine diluted. Hence, it needs to apply normalization method for minimizing result of measurement the spot urine. In radiation emergency, specific gravity method was proposed which method use portable density meter for measuring density of urine and then normalization. The creatinine test recommend by ICRP (1968) and IAEA (1999) is the most common method for urine normalization. However, the creatinine result was various which depends upon sex, age, race and health conditions. Thus it needs to supplementary method for urine normalization. Natural potassium has isotopes those are K-39, K-40, and K-41, in the percentages of 93.08, 0.0118 and 6.91, respectively. Especially, the K-40 emits relatively high energy (1.46 MeV gamma ray) with a half life of 1.248 Χ 10{sup 9}γ. The potassium is an essential element in human which works as homeostatic regulation. Thus human which works as homeostatic regulation. Thus human which works as homeostatic regulation. Thus human body contains specific amount of the potassium and then excreted regularly. And then K-40 is measurable in urine sample using HPGs detector. The purpose of this study is to estimate the variability of spot urine normalization method for assessing the internal exposure dose of hospital workers who work related with radiopharmaceutical produce. The use of creatinine as normalization of spot urine samples for internal dosimetry is possible to reduce level of uncertainty. However, creatinine range is wide which means the creatinine is not exactly correct reference value for normalization. Or some malfunction in creatinine analysis, it need to another supplementary method for normalization for adequately assessing the activity in spot urine samples. In this

  8. Physiochemical Characterization and Release Rate Studies of SolidDispersions of Ketoconazole with Pluronic F127 and PVP K-30

    Science.gov (United States)

    Kumar, Pankaj; Mohan, Chander; KanamSrinivasan Uma Shankar, Mara; Gulati, Monica

    2011-01-01

    In the present study solid dispersions of the antifungal drug Ketoconazole were prepared with Pluronic F-127 and PVP K-30 with an intention to improve its dissolution properties. Investigations of the properties of the dispersions were performed using release studies, Differential scanning calorimetery (DSC), X-ray powder diffraction (XRD) and Fourier transform infrared (FTIR). The results obtained showed that the rate of dissolution of Ketoconazole was considerably improved when formulated in solid dispersions with PVP K-30 and Pluronic F-127 as compared with pure drug and physical mixtures. The results from DSC and XRD studies showed the transition of crystalline nature of drug to amorphous form, while FTIR studies demonstrated the absence of drug-carriers interaction. PMID:24250403

  9. New 30 kA power system at Fermilab and its use for measuring the effects of ripple current on the performance of superconducting high field magnets

    Energy Technology Data Exchange (ETDEWEB)

    Carcagno, R.; Feher, S.; Garvey, J.; Jaskierny, W.; Lamm, M.; Makulski, A.; Orris, D.F.; Pfeffer, H.; Tartaglia, M.; Tompkins, J.; Wolff, D.; /Fermilab

    2004-12-01

    A new 30 kA, 30 V dc Power System was designed, built, and commissioned at Fermilab for testing Superconducting High Field Magnets. This system has been successfully supporting operations at the Fermilab Magnet Test Facility since April 2002. It is based on six commercial 150 kW Power Energy Industries power supply modules and the following in-house modules: six 720 Hz filters, two 15 kA/1kV dc solid-state dump switch, and a 3 MJ/30 kA/1 kV dc dump resistor. Additional inhouse electronic components were designed and built to provide precise current regulation and distribution of current and current rate of change. An industrial-type Programmable Logic Controller system was used to provide equipment interlocks and monitoring. This paper summarizes studies on the influence of characteristics of this new power system--such as ripple current--on the performance of High Field Superconducting magnets.

  10. New 30 kA power system at Fermilab and its use for measuring the effects of ripple current on the performance of superconducting high field magnets

    International Nuclear Information System (INIS)

    Carcagno, R.; Feher, S.; Garvey, J.; Jaskierny, W.; Lamm, M.; Makulski, A.; Orris, D.F.; Pfeffer, H.; Tartaglia, M.; Tompkins, J.; Wolff, D.

    2004-01-01

    A new 30 kA, 30 V dc Power System was designed, built, and commissioned at Fermilab for testing Superconducting High Field Magnets. This system has been successfully supporting operations at the Fermilab Magnet Test Facility since April 2002. It is based on six commercial 150 kW Power Energy Industries power supply modules and the following in-house modules: six 720 Hz filters, two 15 kA/1kV dc solid-state dump switch, and a 3 MJ/30 kA/1 kV dc dump resistor. Additional in-house electronic components were designed and built to provide precise current regulation and distribution of current and current rate of change. An industrial-type Programmable Logic Controller system was used to provide equipment interlocks and monitoring. This paper summarizes studies on the influence of characteristics of this new power system--such as ripple current--on the performance of High Field Superconducting Magnets

  11. International comparison of resistance thermometers between NMIs from Spain, Mexico and Andean countries

    Science.gov (United States)

    del Campo, D.; Ruiz, V. C.; Méndez-Lango, E.; Córdova, L.; von Borries, E.; Sánchez, C. A.; Arévalo, A.; Aguilera, B.; Guillén, E.; Cabrera, C.; Quintana, L.

    2013-09-01

    An international comparison on semi-standard Platinum Resistance Thermometers (PRTs) among the National Metrology Institutes (NMIs) of Spain, Mexico and the Andean Countries (Bolivia, Colombia, Ecuador, Peru and Venezuela) began in 2004 and was successfully completed in 2005. Two PRTs were circulated (hand carried) and compared from -40 °C up to 250 °C. The Centro Español de Metrología (Spanish NMI), CEM, was the pilot laboratory and the Centro Nacional de Metrología (Mexican NMI), CENAM, was the co-pilot laboratory. This paper shows the details of the comparison and the final results as they were presented in the approved final report of the comparison in September of 2005.

  12. Operation test for 200-kW class internally improved MCFC stacks having achieved 5000 hours; 200kW kyu naibu kaishitsu gata MCFC sutakku unten shiken 5,000 jikan tassei

    Energy Technology Data Exchange (ETDEWEB)

    Hashino, K. [Kansai Electric Power Co. Inc., Osaka (Japan)

    2000-03-10

    The operation test for 200-kW class internally improved MCFC stacks being performed at the Amagasaki fuel cell power generation testing plant of Kansai Electric Power Co., Inc. has achieved on January 22, 2000 five thousand hours, the original test time target. Temperature raising has begun on June 18 last year, and the first power generation was carried out on June 30. Since then the operation has continued smoothly at near rated output, and the test was completed nearly as planned without experiencing any trouble caused by Y2K problem. This research is being carried out as the research work shared by the Molten Carbonate Fuel Cell Power Generation System Technology Research Association (MCFC Research Association) based on the research commissioning from NEDO as part of the New Sunshine Project. After the confirmation of the initial performance, verification of the carbon dioxide self-sustaining operation, and the property evaluation test of every 500 hours are going smoothly. The intention hereafter is to achieve 5,000 hours as the power generation time, with the schedule to reduce the stack temperature in the middle of February, and cease the operation. As of January 25, the amount of power generated reached 1,089 MWh. (NEDO)

  13. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, January to February 2013 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    Science.gov (United States)

    Power, O.; Chayramy, R.; Solve, S.; Stock, M.

    2014-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from January to February 2013. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_8 (Z8) and BIPM_9 (Z9), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 5 February 2013. UNML - UBIPM = -0.63 µV uc = 1.31 µV, at 10 V where uc is thecombined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML,based on KJ-90, and the uncertainty related to the comparison. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according

  14. Comparison study on neutronic analysis of the K-DEMO water cooled ceramic breeder blanket using MCNP and ATTILA

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Sung, E-mail: jspark@nfri.re.kr; Kwon, Sungjin; Im, Kihak

    2016-11-01

    Highlights: • A comparison study of main parameter calculations: neutron wall loading (NWL), tritium breeding ratio (TBR), and nuclear heating, on a Korean fusion demonstration reactor (K-DEMO) neutronic analysis model using MCNP and ATTILA was performed to investigate the feasibility of using ATTILA. • The calculation results of this study indicates that ATTILA showed close agreement with MCNP within ranges (3.3–28%). • Partly high discrepancy (17–28%) results between two codes existed to the nuclear heating calculation in high attenuating materials and radially thick structure regions. • The rest of the results showed small differences of NWL calculation (3.3%) and TBR distribution (3.9%). • ATTILA could be acceptable for K-DEMO neutronic analysis considering discrepancy (3.3–28%). - Abstract: A comparison study of main parameter calculations: neutron wall loading (NWL), tritium breeding ratio (TBR), and nuclear heating, on a Korean fusion demonstration reactor (K-DEMO) neutronic analysis model using MCNP and ATTILA was performed to investigate the feasibility of using ATTILA for the main parameter calculations. The model was created by commercial CAD program (Pro-Engineer™) as a 22.5° sector of tokamak consisting of major components such as blankets, shields, divertors, vacuum vessels (VV), toroidal field (TF) coils, and others, which was directly imported into ATTILA by Parasolid file. The discretizing in space, angle, and energy variables were refined for application of the K-DEMO neutronic analysis model through an iterative process since these variables greatly impact on accuracy, solution times, and memory consumptions in ATTILA. The main parameter calculations using ATTILA and the result of comparison studies indicate that the NWL distributions by two codes were almost agreed within discrepancy of 3.3%; the TBR distribution using ATTILA was slightly bigger than MCNP with a difference 3.9%; the nuclear heating values on TF coils and VV

  15. An accurate density functional theory based estimation of pK(a) values of polar residues combined with experimental data: from amino acids to minimal proteins.

    Science.gov (United States)

    Matsui, Toru; Baba, Takeshi; Kamiya, Katsumasa; Shigeta, Yasuteru

    2012-03-28

    We report a scheme for estimating the acid dissociation constant (pK(a)) based on quantum-chemical calculations combined with a polarizable continuum model, where a parameter is determined for small reference molecules. We calculated the pK(a) values of variously sized molecules ranging from an amino acid to a protein consisting of 300 atoms. This scheme enabled us to derive a semiquantitative pK(a) value of specific chemical groups and discuss the influence of the surroundings on the pK(a) values. As applications, we have derived the pK(a) value of the side chain of an amino acid and almost reproduced the experimental value. By using our computing schemes, we showed the influence of hydrogen bonds on the pK(a) values in the case of tripeptides, which decreases the pK(a) value by 3.0 units for serine in comparison with those of the corresponding monopeptides. Finally, with some assumptions, we derived the pK(a) values of tyrosines and serines in chignolin and a tryptophan cage. We obtained quite different pK(a) values of adjacent serines in the tryptophan cage; the pK(a) value of the OH group of Ser13 exposed to bulk water is 14.69, whereas that of Ser14 not exposed to bulk water is 20.80 because of the internal hydrogen bonds.

  16. Comparison and Evaluation of Learning Outcomes from an International Perspective: Development of a Best-Practice Process

    Science.gov (United States)

    Elmgren, Maja; Ho, Felix; Åkesson, Eva; Schmid, Siegbert; Towns, Marcy

    2015-01-01

    Chemistry education focused on learning outcomes is increasingly practiced, providing new opportunities for international comparisons. The interest in intended learning outcomes and constructive alignment has grown in many parts of the world due to both research in higher education and political decisions. In an International Union of Pure and…

  17. International Test Comparisons: Reviewing Translation Error in Different Source Language-Target Language Combinations

    Science.gov (United States)

    Zhao, Xueyu; Solano-Flores, Guillermo; Qian, Ming

    2018-01-01

    This article addresses test translation review in international test comparisons. We investigated the applicability of the theory of test translation error--a theory of the multidimensionality and inevitability of test translation error--across source language-target language combinations in the translation of PISA (Programme of International…

  18. Comparison of food processing retention factors of 137Cs and 40K in vegetables

    International Nuclear Information System (INIS)

    Keiko Tagami; Shigeo Uchida

    2013-01-01

    Removal of radiocesium from food by processing is of great concern following the accident of TEPCO's Fukushima Daiichi Nuclear Power Plant accident. To provide more Cs removal rates, we studied the applicability of K data using edible plant samples. Values were compared for 137 Cs and 40 K of the food processing retention factors, F r (total activity in processed food/total activity in raw food), and they were found to be close to the 1:1 line and highly correlated (R = 0.96, p r ) x 100, for ten vegetable types to provide potential Cs removal rates. The average percent of K removal were as follows: dried pulses, 33; fresh pulses, 15; leafy vegetables, 52; fruit vegetables, 7; flower vegetables, 44: root crops, 18; tubers, 16; ferns, 93: mushrooms, 32; and others, 30. (author)

  19. Recent activity of international comparison for nanoparticle size measurement

    Science.gov (United States)

    Takahashi, Kayori; Takahata, Keiji; Misumi, Ichiko; Sugawara, Kentaro; Gonda, Satoshi; Ehara, Kensei

    2014-08-01

    Nanoparticle sizing is the most fundamental measurement for producing nanomaterials, evaluation of nanostructure, and the risk assessment of nanomaterials for human health. Dynamic light scattering (DLS) is widely used as a useful and convenient technique for determining nanoparticle size in liquid; however, the precision of this technique has been unclear. Some international comparisons are now in progress to verify the measurement accuracy of nanoparticle sizing, as a typical example of Asia Pacific Metrology Programme Supplementary Comparison. In this study, we evaluated the precision of DLS technique for nanoparticle sizing and estimated the uncertainty of the DLS data for polystyrene latex suspensions. The extrapolations of apparent diffusion coefficients to infinite dilution and to lower angles yielded more precise values than those obtained at one angle and one concentration. The extrapolated particle size measured by DLS was compared to the size determined by differential mobility analyzer (DMA), atomic force microscopy (AFM), and scanning electron microscopy (SEM). Before the comparison, the intensity-averaged size measured by DLS was recalculated to the number-averaged size, and the thickness of water layer attaching on the surface of particles were added into uncertainty of particle sizing by DLS. After the recalculation, the consistent values of mean particle diameter were obtained between those by DLS and by DMA, AFM, and SEM within the estimated uncertainties.

  20. Bilateral comparison of 100 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the NSAI-NML, Ireland, and the BIPM, March-August 2011

    Science.gov (United States)

    Power, O.; Moran, A.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the NSAI-NML (Ireland) and the BIPM carried out in 2011. Two 100 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz, for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.b. The results from the NSAI-NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of 0.66 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Bilateral comparison of 10 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.a) between the NSAI-NML, Ireland, and the BIPM, March-August 2011

    Science.gov (United States)

    Power, O.; Moran, A.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the NSAI-NML (Ireland) and the BIPM carried out in 2011. Two 10 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A—B—A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.a. The results from the NSAI-NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of 2.5 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. K2 and K2*: efficient alignment-free sequence similarity measurement based on Kendall statistics.

    Science.gov (United States)

    Lin, Jie; Adjeroh, Donald A; Jiang, Bing-Hua; Jiang, Yue

    2018-05-15

    Alignment-free sequence comparison methods can compute the pairwise similarity between a huge number of sequences much faster than sequence-alignment based methods. We propose a new non-parametric alignment-free sequence comparison method, called K2, based on the Kendall statistics. Comparing to the other state-of-the-art alignment-free comparison methods, K2 demonstrates competitive performance in generating the phylogenetic tree, in evaluating functionally related regulatory sequences, and in computing the edit distance (similarity/dissimilarity) between sequences. Furthermore, the K2 approach is much faster than the other methods. An improved method, K2*, is also proposed, which is able to determine the appropriate algorithmic parameter (length) automatically, without first considering different values. Comparative analysis with the state-of-the-art alignment-free sequence similarity methods demonstrates the superiority of the proposed approaches, especially with increasing sequence length, or increasing dataset sizes. The K2 and K2* approaches are implemented in the R language as a package and is freely available for open access (http://community.wvu.edu/daadjeroh/projects/K2/K2_1.0.tar.gz). yueljiang@163.com. Supplementary data are available at Bioinformatics online.

  3. Thermal Emission of Alkali Metal Ions from Al30-Pillared Montmorillonite Studied by Mass Spectrometric Method.

    Science.gov (United States)

    Motalov, V B; Karasev, N S; Ovchinnikov, N L; Butman, M F

    2017-01-01

    The thermal emission of alkali metal ions from Al 30 -pillared montmorillonite in comparison with its natural form was studied by mass spectrometry in the temperature range 770-930 K. The measurements were carried out on a magnetic mass spectrometer MI-1201. For natural montmorillonite, the densities of the emission currents ( j ) decrease in the mass spectrum in the following sequence (T = 805 K, A/cm 2 ): K + (4.55 · 10 -14 ), Cs + (9.72 · 10 -15 ), Rb + (1.13 · 10 -15 ), Na + (1.75 · 10 -16 ), Li + (3.37 · 10 -17 ). For Al 30 -pillared montmorillonite, thermionic emission undergoes temperature-time changes. In the low-temperature section of the investigated range (770-805 K), the value of j increases substantially for all ions in comparison with natural montmorillonite (T = 805 K, A/cm 2 ): Cs + (6.47 · 10 -13 ), K + (9.44 · 10 -14 ), Na + (3.34 · 10 -15 ), Rb + (1.77 · 10 -15 ), and Li + (4.59 · 10 -16 ). A reversible anomaly is observed in the temperature range 805-832 K: with increasing temperature, the value of j of alkaline ions falls abruptly. This effect increases with increasing ionic radius of M + . After a long heating-up period, this anomaly disappears and the ln j - 1/ T dependence acquires a classical linear form. The results are interpreted from the point of view of the dependence of the efficiency of thermionic emission on the phase transformations of pillars.

  4. Bilateral comparison of 1 V and 10 V standards between the DEFNAT (Tunisia) and the BIPM February to March 2016 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    Science.gov (United States)

    Solve, S.; Chayramy, R.; Ben Salah, B.; Mallat, A.; Abene, L.; Stock, M.

    2016-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Laboratoire de Métrologie Electrique, DEFNAT (Tunisia), was carried out from February to March 2016. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMC (ZC) and BIPM6 (Z6), were transported by freight to DEFNAT and back to BIPM. In order to keep the Zeners powered during their transportation phase, a BIPM in-house voltage stabiliser was connected in parallel to the internal battery. The voltage stabiliser consists of a set of two batteries, electrically protected from surcharge-discharge, easy to recharge and is designed to power two transfer standards for 10 consecutive days. At DEFNAT, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at DEFNAT, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by DEFNAT, at the level of 1.018 V and 10 V, at DEFNAT, UDEFNAT, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 26th of February 2016. UDEFNAT - UBIPM = + 0.07 μV uc = 0.04 μV, at 1.018 V UDEFNAT - UBIPM = + 0.38 μV uc = 0.10 μV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which

  5. SI-traceability of reference materials and reference measurements: From ignoring to realizing

    International Nuclear Information System (INIS)

    Bievre, P. de; Taylor, P.D.P.

    2002-01-01

    Basic principles of traceability of measurements in and to the SI system in general and for measurements of amount of substance in particular are described. Analogies with long-standing traceability schemes in physical measurements are shown and attempts are made to indicate what - as yet barely existing - traceability of amount (-of-substance) measurements could be. The recent start of the CGPM/CIPM/CCQM/BIPM involvement in the field of measurements indicated and possible tasks suggested for these scientific (and legal) guards of the international system of measurements SI (Systeme International). (author)

  6. Once again on Interregional, International and Cross-age Comparison of Unemployment

    OpenAIRE

    Gennadi Kazakevitch

    2003-01-01

    Any discussion on unemployment is never restricted with the data on unemployment only. Unemployment is linked to several key indicators such as number of employed, active population and participation rate. As we often see, increase in unemployment occurs simultaneously with increase in the number of jobs, if participation rate increases at the same time. This makes doubtful any simplistic interregional, international, inter-temporal or cross-age comparison of unemployment data taken in isolat...

  7. Observation of superconductivity at 30∼46K in AxFe2Se2 (A = Li, Na, Ba, Sr, Ca, Yb, and Eu)

    OpenAIRE

    Ying, T. P.; Chen, X. L.; Wang, G.; Jin, S. F.; Zhou, T. T.; Lai, X. F.; Zhang, H.; Wang, W. Y.

    2012-01-01

    New iron selenide superconductors by intercalating smaller-sized alkali metals (Li, Na) and alkaline earths using high-temperature routes have been pursued ever since the discovery of superconductivity at about 30 K in KFe2Se2, but all have failed so far. Here we demonstrate that a series of superconductors with enhanced Tc=30~46 K can be obtained by intercalating metals, Li, Na, Ba, Sr, Ca, Yb, and Eu in between FeSe layers by the ammonothermal method at room temperature. Analysis on their p...

  8. Partial molar volumes of organic solutes in water. XXIV. Selected alkane-α,ω-diols at temperatures T = 298 K to 573 K and pressures up to 30 MPa

    International Nuclear Information System (INIS)

    Cibulka, Ivan; Hnědkovský, Lubomír

    2013-01-01

    Highlights: • Standard molar volumes of three alkane-α,ω-diols (C 5 , C 8 , C 9 ) in water are presented. • Data were obtained in the range T from (298 to 573) K and p up to 30 MPa. • Dependences on carbon atom number, temperature, and pressure are analysed. -- Abstract: Density data for dilute aqueous solutions of three alkane-α,ω-diols (pentane-1,5-diol, octane-1,8-diol, nonane-1,9-diol) are presented together with standard molar volumes (partial molar volumes at infinite dilution) calculated from the experimental data. The measurements were performed at temperatures from T = 298 K up to T = 573 K. Experimental pressures were slightly above the saturation vapour pressure of water, and (15 and 30) MPa. The data were obtained using a high-temperature high-pressure flow vibrating-tube densimeter. Measured standard molar volumes were combined with data previously published for other members of the homologous series and discussed. Experimental standard molar volumes were correlated as a function of temperature and pressure using an empirical polynomial function. Dependences of standard molar volumes on temperature and pressure were analysed. Contributions of the methylene group to the standard molar volume were also evaluated and discussed

  9. A CFD code comparison of wind turbine wakes

    International Nuclear Information System (INIS)

    Van der Laan, M P; Sørensen, N N; Storey, R C; Cater, J E; Norris, S E

    2014-01-01

    A comparison is made between the EllipSys3D and SnS CFD codes. Both codes are used to perform Large-Eddy Simulations (LES) of single wind turbine wakes, using the actuator disk method. The comparison shows that both LES models predict similar velocity deficits and stream-wise Reynolds-stresses for four test cases. A grid resolution study, performed in EllipSys3D and SnS, shows that a minimal uniform cell spacing of 1/30 of the rotor diameter is necessary to resolve the wind turbine wake. In addition, the LES-predicted velocity deficits are also compared with Reynolds-Averaged Navier Stokes simulations using EllipSys3D for a test case that is based on field measurements. In these simulations, two eddy viscosity turbulence models are employed: the k-ε model and the k-ε-f p model. Where the k-ε model fails to predict the velocity deficit, the results of the k-ε-f P model show good agreement with both LES models and measurements

  10. Diagnosis of canine visceral leishmaniasis with radiolabelled probes: comparison of the kDNA PCR-hybridization with three molecular methods in different clinical samples

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Aline Leandra C.; Ferreira, Sidney A.; Carregal, Virginia M.; Andrade, Antero Silva R., E-mail: antero@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Lab. de Radiobiologia; Melo, Maria N., E-mail: melo@icb.ufmg.br [Departamento de Parasitologia. Instituto de Ciencias Biologicas. Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil)

    2011-07-01

    Leishmania (Leishmania) chagasi is responsible for visceral leishmaniasis (VL) in Brazil and the dog is the main domestic reservoir. Disease control is based on the elimination of infected animals and the use of a sensitive and specific diagnostic test is necessary. The Brazilian VL control program emphasizes serologic surveys, mainly using the enzyme-linked immunosorbent assay (ELISA) and the immunofluorescence antibody test (IFAT), followed by the elimination of the seropositive dogs. However, these techniques present limitations in terms of sensitivity and specificity. The Polymerase Chain Reaction (PCR) associated to hybridization with DNA probes labeled with {sup 32}P has been recognized as a valuable tool for Leishmania identification. In this study, the sensitivity of kDNA PCR hybridization method was compared with three other molecular methods: Internal Transcribed Spacer 1 Nested PCR (ITS-1nPCR), Leishmania nested PCR (LnPCR) and Seminested kDNA PCR (kDNA snPCR). The comparison was performed in different clinical specimens: conjunctival swab, skin, blood and bone marrow. A group of thirty symptomatic dogs, positive in the parasitological and serological tests, was used. When. The techniques targeting kDNA mini-circles (kDNA snPCR and KDNA PCR-hybridization) showed the worst result for blood samples. The KDNA-PCR hybridization showed the best sensitivity for conjunctival swab. By comparing the samples on the basis of positivity obtained by the sum of all methods, the blood showed the worst outcome (71/120).The bone marrow showed the highest positivity (106/120), followed by conjunctival swab (100/120) and skin (89/120). Since the bone marrow samples are unsuitable for routine epidemiological surveys, the conjunctival swab was recommended because it allows high sensitivity, especially when associated with kDNA PCR hybridization method, and is a noninvasive sampling method. (author)

  11. Diagnosis of canine visceral leishmaniasis with radiolabelled probes: comparison of the kDNA PCR-hybridization with three molecular methods in different clinical samples

    International Nuclear Information System (INIS)

    Ferreira, Aline Leandra C.; Ferreira, Sidney A.; Carregal, Virginia M.; Andrade, Antero Silva R.

    2011-01-01

    Leishmania (Leishmania) chagasi is responsible for visceral leishmaniasis (VL) in Brazil and the dog is the main domestic reservoir. Disease control is based on the elimination of infected animals and the use of a sensitive and specific diagnostic test is necessary. The Brazilian VL control program emphasizes serologic surveys, mainly using the enzyme-linked immunosorbent assay (ELISA) and the immunofluorescence antibody test (IFAT), followed by the elimination of the seropositive dogs. However, these techniques present limitations in terms of sensitivity and specificity. The Polymerase Chain Reaction (PCR) associated to hybridization with DNA probes labeled with 32 P has been recognized as a valuable tool for Leishmania identification. In this study, the sensitivity of kDNA PCR hybridization method was compared with three other molecular methods: Internal Transcribed Spacer 1 Nested PCR (ITS-1nPCR), Leishmania nested PCR (LnPCR) and Seminested kDNA PCR (kDNA snPCR). The comparison was performed in different clinical specimens: conjunctival swab, skin, blood and bone marrow. A group of thirty symptomatic dogs, positive in the parasitological and serological tests, was used. When. The techniques targeting kDNA mini-circles (kDNA snPCR and KDNA PCR-hybridization) showed the worst result for blood samples. The KDNA-PCR hybridization showed the best sensitivity for conjunctival swab. By comparing the samples on the basis of positivity obtained by the sum of all methods, the blood showed the worst outcome (71/120).The bone marrow showed the highest positivity (106/120), followed by conjunctival swab (100/120) and skin (89/120). Since the bone marrow samples are unsuitable for routine epidemiological surveys, the conjunctival swab was recommended because it allows high sensitivity, especially when associated with kDNA PCR hybridization method, and is a noninvasive sampling method. (author)

  12. Monte Carlo modelling of Germanium detectors for the measurement of low energy photons in internal dosimetry: Results of an international comparison

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Ros, J.M. [CIEMAT, Av. Complutense 22, E-28040 Madrid (Spain)], E-mail: jm.gomezros@ciemat.es; Carlan, L. de [CEA DRT/LIST/DETECS/LNHB/LMD, Bat 534, F-91191 Gif sur Yvette, Cedex (France); IRSN DRPH/SDI/LEDI, BP6, F-92262, Fontenay-aux-Roses, Cedex (France); Franck, D. [IRSN DRPH/SDI/LEDI, BP6, F-92262, Fontenay-aux-Roses, Cedex (France); Gualdrini, G. [ENEA ION-IRP, Via dei Colli 16, I-40136 Bologna (Italy); Lis, M.; Lopez, M.A.; Moraleda, M. [CIEMAT, Av. Complutense 22, E-28040 Madrid (Spain); Zankl, M. [GSF - National Research Center for Environment and Health, D-85764 Neuherberg (Germany); Badal, A. [Institut de Tecniques Energetiques, UPC, Diagonal 647, 08028 Barcelona (Spain); Capello, K. [Human Monitoring Laboratory (Canada); Cowan, P. [Serco Assurance, Bld. A32, Winfrith Tech. Centre Winfrith, Dorchester, Dorset DT2 8DH (United Kingdom); Ferrari, P. [ENEA ION-IRP, Via dei Colli 16, I-40136 Bologna (Italy); Heide, B. [Forschungszentrum Karlsruhe, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Henniger, J. [Technical University of Dresden, 01062 Dresden (Germany); Hooley, V. [Serco Assurance, Bld. A32, Winfrith Tech. Centre Winfrith, Dorchester, Dorset DT2 8DH (United Kingdom); Hunt, J. [IRD, Av. Salvador Allende, s/n, Recreio, Rio de Janeiro (Brazil); Kinase, S. [Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki-ken 319-1195 (Japan); Kramer, G.H. [Human Monitoring Laboratory (Canada); Loehnert, D. [Technical University of Dresden, 01062 Dresden (Germany); Lucas, S. [LARN Laboratory, University of Namur, Rue de Bruxelles 61, B-5000 Namur (Belgium)] (and others)

    2008-02-15

    This communication summarizes the results concerning the Monte Carlo (MC) modelling of Germanium detectors for the measurement of low energy photons arising from the 'International comparison on MC modelling for in vivo measurement of Americium in a knee phantom' organized within the EU Coordination Action CONRAD (Coordinated Network for Radiation Dosimetry) as a joint initiative of EURADOS working groups 6 (computational dosimetry) and 7 (internal dosimetry). MC simulations proved to be an applicable way to obtain the calibration factor that needs to be used for in vivo measurements.

  13. First results from the International Urban Energy Balance Model Comparison: Model Complexity

    Science.gov (United States)

    Blackett, M.; Grimmond, S.; Best, M.

    2009-04-01

    A great variety of urban energy balance models has been developed. These vary in complexity from simple schemes that represent the city as a slab, through those which model various facets (i.e. road, walls and roof) to more complex urban forms (including street canyons with intersections) and features (such as vegetation cover and anthropogenic heat fluxes). Some schemes also incorporate detailed representations of momentum and energy fluxes distributed throughout various layers of the urban canopy layer. The models each differ in the parameters they require to describe the site and the in demands they make on computational processing power. Many of these models have been evaluated using observational datasets but to date, no controlled comparisons have been conducted. Urban surface energy balance models provide a means to predict the energy exchange processes which influence factors such as urban temperature, humidity, atmospheric stability and winds. These all need to be modelled accurately to capture features such as the urban heat island effect and to provide key information for dispersion and air quality modelling. A comparison of the various models available will assist in improving current and future models and will assist in formulating research priorities for future observational campaigns within urban areas. In this presentation we will summarise the initial results of this international urban energy balance model comparison. In particular, the relative performance of the models involved will be compared based on their degree of complexity. These results will inform us on ways in which we can improve the modelling of air quality within, and climate impacts of, global megacities. The methodology employed in conducting this comparison followed that used in PILPS (the Project for Intercomparison of Land-Surface Parameterization Schemes) which is also endorsed by the GEWEX Global Land Atmosphere System Study (GLASS) panel. In all cases, models were run

  14. International comparison of calibration standards for exposure and absorbed dose

    International Nuclear Information System (INIS)

    Horakova, I.; Wagner, R.

    1990-01-01

    A comparison was performed of the primary calibration standards for 60 Co gamma radiation dose from Czechoslovakia (UDZ CSAV, Prague), Austria (OEFZS/BEV Seibersdorf) and Hungary (OMH Budapest) using ND 1005 (absolute measurement) and V-415 (by means of N x ) graphite ionization chambers. BEV achieved agreement better than 0.1%, OMH 0.35%. Good agreement was also achieved for the values of exposure obtained in absolute values and those obtained via N x , this for the ND 1005/8105 chamber. The first ever international comparison involving Czechoslovakia was also performed of the unit of absorbed gamma radiation in a water and/or graphite phantom. The participants included Czechoslovakia (UDZ CSAV Prague), the USSR (VNIIFTRI Moscow) and Austria (OEFZS/BEV Seibersdorf). In all measurements, the agreement was better than 1%, which, in view of the differences in methodologies (VNIIFTRI, BEV: calorimetry, UDZ, UVVVR: ionometry) and the overall inaccuracies in determining the absorbed dose values, is a good result. (author)

  15. Bilateral comparison of 1 V and 10 V standards between the NMISA (South Africa) and the BIPM April to June 2017 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    Science.gov (United States)

    Solve, S.; Chayramy, R.; Matlejoane, A. M.; Magagula, L.; Stock, M.

    2018-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and the National Metrology Institute of South Africa, NMISA (South Africa), was carried out from April to June 2017. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMA (ZA) and BIPMB (ZB), were transported by freight to NMISA and back to BIPM. In order to keep the Zeners powered during their transportation phase, a voltage stabilizer developed by BIPM was connected in parallel to the internal battery. It consists of a set of two batteries, electrically protected from surcharge-discharge, easy to recharge and is designed to power two transfer standards for ten consecutive days. At NMISA, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NMISA, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NMISA, at the level of 1.018 V and 10 V, at NMISA, UNMISA, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference dates of the 19th and 18th of May 2017, respectively. UNMISA - UBIPM = + 0.07 μV uc = 0.02 μV, at 1.018 V UNMISA - UBIPM = + 0.001 μV uc = 0.34 μV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NMISA, based on KJ-90, and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which

  16. Search for the suppressed decays B+ -> K+K+pi(-) and B+ -> pi(+)pi K-+(-)

    NARCIS (Netherlands)

    Aaij, R.; Adeva, B.; Adinolfi, M.; Ajaltouni, Z.; Akar, S.; Albrecht, J.; Alessio, F.; Alexander, M. H.; Ali, S.; Alkhazov, G.; Cartelle, P. Alvarez; Alves, A. A. Jr; Amato, S.; Amerio, S.; Amhis, Y.; BEACH, LA; Anderlini, L.; Andreassi, G.; Andreotti, M.; Andrews, J.E.; Appleby, R.B.; Gutierrez, O. Aquines; Archilli, F.; d'Argent, P.; Romeu, J. Arnau; Artamonov, AY; Artuso, M.; Aslanides, E.; Auriemma, G.; Baalouch, M.; Babuschkin, I.; Bachmann, S; Back, Jaap Willem; Badalov, A.; Baesso, C.; Baldini, W.; Barlow, R.J.; Barschel, C.; Barsuk, S.; Barter, W.; Batozskaya, V.; Batsukh, B.; Battista, V.; Beaucourt, L.; Beddow, J.; Bedeschi, F.; Bediaga, I.; Be, L. J.; Bellee, V.; Belloli, N.; Belous, K.; Belyaev, I.; Ben-Haim, E.; Bencivenni, G.; Benson, S; Benton, J.; Berezhnoy, A.; Bernet, R.; Bertolin, A.; Betti, F.; Bettler, M.O.; van Beuzekom, MG; Bifani, S.; Billoir, P.; Bird, T.; Birnkraut, A.; Bitadze, A.; Bizzeti, A.; Blake, T.; Blanc, F.; Blouw, J.; Blusk, S.; Bocci, V.; Boettcher, Thomas; Bondar, A.; Bondar, N.; Bonivento, W.; Borgheresi, A.; Borghi, S.; Borisyak, M.; Borsato, M.; Bossu, F.; Boubdir, M.; Bowcock, T. J. V.; Bowen, D.E.; Bozzi, C.; Braun, S.; Britsch, M.; Britton, T.; Brodzicka, J.; Buchanan, E.; Burr, C.; Bursche, A.; Buytaert, R. J.; Cadeddu, S.; Calabrese, J. R.; Calvi, M.; Calvo Gomez, M.; Camboni, A.; Campana, P.; Perez, D. Campora; Perez, D. H. Campora; Capriotti, L.; Carbone, A.; Carboni, G.; Cardinale, R.; Cardini, A.; Carniti, P.; Carson, L.; Carvalho Akiba, K.; Casse, G.; Cassina, L.; Garcia, L. Castillo; Cattaneo, M.; Cauet, Ch.; Cavallero, G.; Cenci, R.; Charles, M; Charpentier, Ph.; Chatzikonstantinidis, G.; Chefdeville, M.; Cheung, T.F.S.; Chobanova, V.; Chobanova, V.; Chrzaszcz, M.; Vidal, X. Cid; Ciezarek, G.; Clarke, P. E. L.; Clemencic, M.; Cliff, H. V.; Closier, J.; Coco, V.; Cogan, J.; Cogneras, E.; Cogonilf, V.; Cojocariu, L.; Collazuol, G.; Collins, P.; Comerma-Montells, A.; Contu, A.; COOK, AM; Coquereau, S.; Corti, G.; Corvo, M.; Sobral, C. M. Costa; Couturier, B.; Cowan, G. A.; Craik, D. C.; Crocombe, A. C.; Torres, M. Cruz; Cunliffe, S.; Currie, R.; D'Ambrosio, C.; Dall'Occo, E.; Dalseno, J.; David, P. N. Y.; Davis, A.; De Aguiar Francisco, O.; De Bruyn, K.; De Capua, S.; De Cian, M.; Miranda, J. M.; De Paula, L.; De Serio, M.; De Simone, Paolo; Dean, C. -T.; Decamp, D.; Deckenhoffl, M.; Del Buono, L.; Demmer, M.; Derkach, D.; Deschamps, O.; Dettori, F.; Dey, B.; Di Canto, A.; Dordei, F.; Dorigo, M.; Suarez, A. Dosil; Dovbnya, A.; Dreimanis, K.; Dufour, L.; Dujany, G.; Dungs, K.; Durante, P.; Dzhelyadin, R.; Dziurda, A.; Dzyuba, A.; Deleage, N.; Easo, S.; Ebert, Martin A.; Egede, U.; Egorychev, V.; Eidelman, S.; Eisenhardt, S.; Eitschberger, U.; Ekelhof, R.; Eklund, L.; Elsasser, Ch.; Ely, SIdi Ould; Esen, S.; Evans, Helen M.; Evans, T.; Falabella, A.; Farley, N.; Farry, S.; Fay, R. F.; Fazzini, D.; FERGUSON, D; Fernandez Albor, V.; Fernandez Prieto, A.; Ferrari, F; Rodrigues, F. Ferreira; Ferro-Luzzi, M.; Filippov, S.; Fiore, M; Fiorini, M.; Firlej, M.; Fitzpatrick, C.; Fiutowski, T.; Fleuret, F.; Fohl, K; Fontana, M.; Fontanelli, F.; Forshaw, D. C.; Forty, R.; Frei, C.; Furfaro, E.; Farber, CR; Gallas Torreira, A.; Galli, D.; Gallorini, S.; Gambetta, S.; Gandelman, M.; Gandini, P.; Garcia Martin, L. M.; Garcia Pardinas, J.; Tico, J. Garra; Garrido, L.; Garsed, P. J.; Gascon, D.; Gaspar, C; Gavardi, L.; Gazzoni, G.; Gerick, D.; Gersabeck, E. G; Gersabeck, M.; Gershon, T.; Ghez, Ph.; Giani', S.; Gibson, V.; Girard, O. G.; Giubega, L.; Gizdov, K.; Gligorov, V. V.; Golubkov, D.; Golutvin, A.; Gorelov, I. V.; Gotti, C.; Gandara, M. Grabalosa; Graciani Diaz, R.; Cardoso, L. A. Granado; Grauges, E.; Graverini, E.; Graziani, G.; Grecu, A.; Griffith, P.; Grillo, L.; Cazon, B. R. Gruberg; Gruenberg, O.; Gushchin, EM; Guz, Yu.; Gys, T.; Gobel, C.; Hadavizadeh, T.; Hadjivasiliou, C.; Haefeli, G.; Haen, C.; Haines, S. C.; Hal, S.; Hamilton, D.B.; Hansmann-Menzemer, S.; Harnew, N.; Harnew, S. T.; Harrison, Christine J.; Hatch, M.; He, J. J.; Head, T.; Heister, J. A.; Hennessy, K.; Henrard, P.; Henry, Lee; Hernando Morata, J. A.; Van Herwijnen, E.; Hess, M.; Hicheur, A.; HILL, D; Hombach, C.; Hulsbergen, W.; Humair, T.; Hushchyn, M.; Hutchcroft, D.; Idzik, M.; Ilten, P.; Jacobsson, R.; Jalocha, J.; Jans, E.; Jawahery, A.; John, Jestinah M. Mahachie; Johnson, D; Jones, Jonathan C. R.; Joram, C.; Jost, B.; Jurik, N.; Kandybei, S.; Kanso, W.; Karacson, M.; Kariuki, J. M.; Karodia, S.; Kecke, M.; Kelsey, M.; Kenyon, I. R.; Kenzie, M.; Ketel, T. J.; Khairullin, E.; Khanji, B.; Khurewathanakul, C.; Kirn, T.; Klaver, N. S.; Klimaszewski, K.; Koliiev, S.; Kolpin, M.; Komarov, I.; Koppenburg, P.; Kozachuk, A.; Kozeiha, M.; Kravchuk, Vladimir Leonidovich; Kreplin, K.; Kreps, M.; Krokovny, P.; Krzemien, W.; Kucewicz, W.; Kucharczyk, M.; Kudryavtsev, V.; Kuonen, A. K.; Kurek, K.; Kvaratskheliya, T.; Lacarrere, D.; Lafferty, G.; Lai, A.; Lambert, D.; Lanfranchi, G.; Langenbruch, C.; Langhans, B.; Latham, T.; Lazzeroni, C.; Le Gac, R.; Van Leerdam, J.; Lees, J. -P.; Leflat, A.; Lefrancois, J.; Lefevre, R.; Lemaitre, F.; Lemos Cid, E.; Leroy, O.; Lesiak, T.; Leverington, B.; Likhomanenko, T.; Lindner, R.; Linn, C.; Lionetto, F.; Loh, D.; Longstaff, I.; Lopes, J. H.; Lucchesi, D.; Lucio Martinez, M.; Luo, Haibin; Lupato, A.; Luppi, E.; Lupton, O.; Lusiani, A.; Lyu, X. R.; Machefert, F.; Maciuc, F.; Maev, O.; Maguire, Kate; Malde, S.; Malinin, A.; Maltsev, T.; Manca, G.; Mancinelli, G.; Manning, P.; Maratas, J.; Marchand, J. F.; Marconi, U.; Marin Benito, C.; Marino, Paolo; Marks, J. D.; Martellotti, G.; Martinelli, M.; Martinez Santos, D.; Martinez Vidal, F.; Martins Tostes, D.; Massacrier, L. M.; Massafferri, A.; Matev, R.; Mathad, A.; Mathe, Z.; Matteuzzi, C.; Mauri, A.; Maurin, B.; Mazurov, A.; McCann, Linda M.; McCarthy, Patrick J.; McNab, A.; McNulty, R.; Meadows, B.; Meier, F.; Melnychuk, D.; Merk, M.; Merli'q, A.; Michielin, E.; Milanes, D. A.; Minard, M. -N.; Mitzel, D. S.; Molina Rodriguez, J.; Moreno-Monroy, Ana I.; Monteil, S.; Morandin, M.; Morawski, P.; Morda, A.; Morello, M. J.; Moron, J.; Morris, A. -B.; Mountain, R.; Muheim, F.; Mulder, M.; Mussini, M.; Mueller, J.; Mueller, K.; Mueller, Volker; Naik, P.; Nakada, T.; Nandakumar, R.; Nandi, A.; Nasteva, I.; Needham, M.; Neri, N.; Neubert, S.; Neufeld, N.; Neuner, M.; Nguyen, A. D.; Nguyen-Mau, C.; Nieswand, S.; Niet, R.; Nikitin, N.; Nikodem, T.; Novoselov, A.; O'Hanlon, D. P.; Oblakowska-Mucha, A.; Obraztsov, V.; Ogilvy, S.; Oldeman, R.; Onderwater, C. J. G.; Goicochea, J. M. Otalora; Otto, A.; Owen, Randall P.; Oyanguren, A.; Pais, P. R.; Palano, A.; Palombo, F.; Palutan, M.; Papanestis, A.; Pappagallo, M.; Pappalardo, L.; Pappenheimer, C.; Parker, Anthony W.; Parkes, C.; Passaleva, G.; Patel, G. D.; Patrignani, C.; Pearce, A.; Pellegrino, A.; Penso, G.; Altarelli, M. Pepe; Perazzini, S.; Perret, P.; Pescatore, L.; Petridis, K.; Petrolini, A.; Petrov, A. D.; Petruzzo, M.; Picatoste Olloqui, E.; Pietrzyk, B.; Pikies, M.; Pinci, D.; Pistone, A.; Piucci, A.; Playfer, S.; Plo Casasus, M.; Poikela, T.; Polci, F.; Poluektov, A.; Polyakov, I.; Polycarpo, E.; Pomery, G. J.; Popov, A.; Popov, D.; Popovici, B.; Potterat, C.; Price, P. E.; Price, Daniel J.; Prisciandaro, J.; Pritchard, A.; Prouve, C.; Pugatch, V.; Navarro, A. Puig; Punzi, G.; Qian, S. W.; Quagliani, R.; Rachwal, B.; Rademacker, J. H.; Rama, M.; Ramos Pernas, M.; Rangel, M. S.; Raniuk, I.; Raven, G.; Redi, F.; Reichert, Andreas S.; Dos Reis, A. C.; Remon Alepuz, C.; Renaudin, V.; Ricciardi, S.; Richards, S.; Rihl, M.; Rinnert, K.; Rives Molina, V.; Rodrigues, A. B.; Rodrigues, Eliane R.; Rodriguez Lopez, J. A.; Perez, P. Rodriguez; Rogozhnikov, A.; Roiser, S.; Romanovskiy, V.; Romero Vidal, A.; Ronayne, J. W.; Rotondo, M.; Ruf, Thomas; Ruiz Valls, P.; Saborido Silva, J. J.; Sadykhov, E.; Sagidova, N.; Saitta, B.; Salustino Guimaraes, V.; Sanchez Mayordomo, C.; Sanmartin Sedes, B.; Santacesaria, R.; Santamarina Rios, C.; Santimaria, M.; Santovetti, E.; Sarti, A.; Satriano, C.; Satta, A.; Saunders, D. M.; Savrina, D.; Schael, S.; Schindler, H.; Schlupp, M.; Schmelling, M.; Schmelzer, T.; Schmidt, B.; Schneider, O.; Schopper, A.; Schubiger, M.; Schune, M. -H.; Schwemmer, R.; Sciascia, B.; Sciubba, A.; Semennikov, A.; Sergi, A.; Serra, N.; Gonzalez-Serrano, J.; Sestini, L.; Seyfert, P.; Shapkin, M.; Shapoval, I.; Shcheglov, Y.; Shears, T.; Shekhtman, L.; Shevchenko, V.; Shires, A.; Siddi, B. G.; Coutinho, R. Silva; Silva de Oliveira, L.; Simi, G.; Simone Doolaard, [No Value; Sirendi, M.; Skidmore, N.; Skwarnicki, T.; Smith, I. T.; Snoek, H.; Sokoloff, M. D.; Soler, F. J. P.; Souza, Thomas G. D’; Souza De Paula, B.; Spaan, B.; Spradlin, P.; Sridharan, S.; Stagni, F.; Stahl, M.; Stahl, Sherin S.; Stefko, P.; Stefkova, S.; Steinkamp, O.; Stenyakin, O.; Stevenson, S.; Stone, Ian S.; Storaci, B.; Stracka, S.; Straticiuc, M.; Straumann, U.; Sutcliffe, W.; Swientek, K.; Syropoulos, V.; Szczekowski, M.; Szumlak, T.; T'Jampens, S.; Tayduganov, A.; Tekampe, T.; Tellarini, G.; Teubert, E.; Tilburg, Jeroen J H C; Tisserand, V.; Tobin, M; Tolk, S.; Tomassetti, L.; Tonelli, D.; Topp-Joergensen, S.; Toriello, F.; Tournefier, E.; Tourneur, S.; Trabelsi, K.; Traill, M.; Tresch, M.; Trisovic, A.; Tsaregorodtsev, A.; Tsopelas, P.; Tully, A.; Tuning, N.; Ukleja, A.; Ustyuzhanin, A.; Uwer, U.; Vacca, C.; Vagnoni, V.; Valat, S.; Valenti, G.; Vallier, A.; Gomez, R. Vazquez; Vazquez Regueiro, P.; Vecchi, S.; van Veghel, M.; Veithuis, J. J.; Veltri, M.; Veneziano, G.; Venkateswaran, A.; Vesterinen, M.; Viaud, B.; VIEIRA, DF; Vieites Diaz, M.; Vilasis-Cardona, X.; Volkov, V.; Vollhardt, A.; Voneki, B.; Voong, D.; Vorobyev, A.; Vorobyev, V.; Voss, C.; Vazquez Sierra, C.; Waldi, R.; Wallace, C.; Wallace, R; Ward, D. R.; Wark, H. M.; Watson, N. K.; Websdale, D.; Weiden, A.; Whitehead, M.; Wicht, J.; Wilkinson, G.; Williams, Tishan; Wilson, F. Perry; Wimberley, J.; Wishahi, J.; Wislicki, W.; Witek, M.; Wormser, G.; Wotton, S. A.; Wraight, K.; Wright, S.; Wyllie, K.; Xie, Y; Xing, Zhe; Yang, Z.; Yu, J.; Yuan, X.-L.; Yushchenko, O.; Zangoli, M.; Zarebski, K. A.; Zavertyaev, M.; Zhelezov, A.; Zheng, Y.; Zhokhov, A.; Zhukov, V.; Zucchelli, S.; Collaboration, Lhcb

    2017-01-01

    A search is made for the highly-suppressed B meson decays B+ -> K+K+pi(-) and B+ -> pi(+)pi K-+(-) using a data sample corresponding to an integrated luminosity of 3.0 fb(-1) collected by the LHCb experiment in proton-proton collisions at centre-of-mass energies of 7 and 8 TeV. No evidence is found

  17. 30th Detroit International Jazz Festival 向爵士家族致敬

    Institute of Scientific and Technical Information of China (English)

    沙拉

    2009-01-01

    今年9月,底特律国际爵士音乐节(Detroit International Jazz Festival)迎来了自己的30岁生日。这个美国最大的免费爵士音乐节大概不会受到当地汽车业的影响,该庆祝的时候还是要庆祝。

  18. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, February to March 2012 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    Science.gov (United States)

    Power, O.; Solve, S.; Chayramy, R.; Stock, M.

    2012-01-01

    As part of the on-going BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from February to March 2012. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_C (ZC) and BIPM_D (ZD), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson voltage standard. Results of all measurements were corrected for the dependence of the output voltages on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 23 February 2012. UNML - UBIPM = +0.83 µV, uc = 1.35 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. The final result is impacted by the anomalous offset between the NSAI-NML results for the two transfer standards. The reason for this offset hasn't been determined. However, the difference remains within the total combined standard uncertainty. Therefore, the comparison result shows that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated expanded uncertainties, on the mean date of the comparison. Main text. To reach the main text of

  19. A System of Three Super Earths Transiting the Late K-Dwarf GJ 9827 at 30 pc

    Science.gov (United States)

    Rodriguez, Joseph E.; Vanderburg, Andrew; Eastman, Jason D.; Mann, Andrew W.; Crossfield, Ian J. M.; Ciardi, David R.; Latham, David W.; Quinn, Samuel N.

    2018-02-01

    We report the discovery of three small transiting planets orbiting GJ 9827, a bright (K = 7.2) nearby late K-type dwarf star. GJ 9827 hosts a 1.62 ± 0.11 {R}\\oplus super Earth on a 1.2 day period, a {1.269}-0.089+0.087 {R}\\oplus super Earth on a 3.6 day period, and a 2.07 ± 0.14 {R}\\oplus super Earth on a 6.2 day period. The radii of the planets transiting GJ 9827 span the transition between predominantly rocky and gaseous planets, and GJ 9827 b and c fall in or close to the known gap in the radius distribution of small planets between these populations. At a distance of 30 pc, GJ 9827 is the closest exoplanet host discovered by K2 to date, making these planets well-suited for atmospheric studies with the upcoming James Webb Space Telescope. The GJ 9827 system provides a valuable opportunity to characterize interior structure and atmospheric properties of coeval planets spanning the rocky to gaseous transition.

  20. Psychometric Properties of the Catastrophic Cognitions Questionnaire-Modified (CCQ-Modified) Among Community Samples in Malaysia.

    Science.gov (United States)

    Abdul Khaiyom, Jamilah Hanum; Mukhtar, Firdaus; Ibrahim, Normala; Mohd Sidik, Sherina; Oei, Tian Po Sumantri

    2016-12-01

    The Catastrophic Cognitions Questionnaire-Modified (CCQ-M) is a common instrument for measuring catastrophic thoughts. In some countries, however, CCQ-M still poses concerns following the lack of appropriate validation among their populations. The current study aimed to examine the factor structure of the CCQ-M, the reliability, and the validity in community samples in Malaysia. The Malay version of CCQ-M and additional measures assessing the symptoms and cognitions relevant to anxiety disorders were completed by 682 university students and general community. Exploratory factor analysis revealed a two-factor structure accounting for 62.2% of the total variance. Confirmatory factor analysis confirmed the two-factor model by deleting four items. The Cronbach's alpha coefficients for the total and the two subscales were .94, .90, and .92, respectively. Test-retest reliability analysis was conducted on 82 university students in the interval period of 14 days, and the result was r = .58. Evidence supported the concurrent, convergent, and discriminant validity. In conclusion, the 17-item CCQ-M-Malaysia is a valid and reliable instrument for assessing catastrophic cognitions among Malaysian populations. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Toward an International Comparison of Economic and Educational Mobility: Recent Findings from the Japan Child Panel Survey

    Science.gov (United States)

    Akabayashi, Hideo; Nakamura, Ryosuke; Naoi, Michio; Shikishima, Chizuru

    2016-01-01

    In the past decades, income inequality has risen in most developed countries. There is growing interest among economists in international comparisons of economic and educational mobility. This is aided by the availability of internationally comparable, large-scale data. The present paper aims to make three contributions. First, we introduce the…

  2. Comparison of a state of the art Si IGBT and next generation fast switching devices in a 4 kW boost converter

    DEFF Research Database (Denmark)

    Anthon, Alexander; Zhang, Zhe; Andersen, Michael A. E.

    2015-01-01

    This paper gives a comprehensive comparison of two promising silicon carbide (SiC) switching devices, i.e. normally-off SiC MOSFET and a normally-on SiC JFET, as alternatives to a conventional state of the art Si IGBT. The comparison uses datasheet information to determine conduction losses, swit...... losses. This reduction in semiconductor losses can increase overall converter efficiencies up to 0.4% at 20kHz or enable high frequency operation up to 100 kHz which then reduces the size and weight of the inductor by more than 75% while still achieving efficiencies over 98.3 %....

  3. Subthreshold and near-threshold K+-meson photoproduction on nuclei

    International Nuclear Information System (INIS)

    Paryev, E.Ya.

    2000-01-01

    The inclusive K + -meson production in photon-induced reactions in the near-threshold and subthreshold energy regimes is analyzed for the one-step (γN → K + Y, Y = Λ, Σ) incoherent production processes on the basis of an appropriate new folding model that takes properly into account the struck-target nucleon-removal energy and the internal momentum distribution (nucleon spectral function), extracted from recent quasielastic-electron-scattering experiments and from many-body calculations based on realistic models of NN interaction. Simple parametrizations of the total and differential cross sections for K + production in photon-nucleon collisions are presented. A comparison of the model calculations of the K + differential cross sections for γ 12 C interactions in the threshold region with existing experimental data is given, which displays the contributions to K + production at considered incident energies from the use of the single-particle part, as well as high momentum and high removal energy part, of the nucleon spectral function. Detailed predictions for the K + total and differential cross sections for γ 2 H, γ 12 C, and γ 208 Pb interactions at subthreshold and near-threshold energies are provided. The effect of the uncertainties in the elementary K + -production cross sections on the K + yield is explored

  4. Intercomparison of Primary Manometers in the Range 30 kPa to 110 kPa: Pressure Balance at the LNE and Mercury Manometer at the VNIIFTRI

    Science.gov (United States)

    Astrov, D. N.; Guillemot, J.; Legras, J. C.; Zakharov, A. A.

    1994-01-01

    An intercomparison between the primary pressure balance of the LNE and a mercury manometer developed at the All-Russian Research Institute for Physical, Technical and Radio-Technical Measurements (VNIIFTRI) for purposes of temperature measurement was undertaken in 1990. A short description of the two standards is given. The transfer standard was a pressure balance equipped with a piston-cylinder assembly that has the same characteristics as the standard of the Laboratoire National d'Essais (LNE). The results obtained from 30 kPa to 110 kPa showed a systematic relative difference of 12 parts in 106 between the two standards. This difference is significant, as the combined relative uncertainty at 1 σ level is estimated to be 4,2 parts in 106. These results are analysed in this paper.

  5. International key comparison of measurements of neutron source emission rate (1999-2005): CCRI(III)-K9.AmBe

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, N.J.; Jones, L.N. [National Physical Laboratory (NPL), Teddington, (United Kingdom); Wang, Z.; Liu, Y.; Wang, Q.; Chen, X.; Luo, H.; Rong, C. [China Institute of Atomic Energy (CIAE), Beijing (China); Kralik, M. [Czech Metrology Institute (CMI), Praha, (Czech Republic); Park, H.; Choi, K.O. [Korea Research Institute of Standards and Science (KRISS), Daejeon, (Korea, Republic of); Pereira, W.W.; Da Fonseca, E.S. [National Laboratory of Metrology of Ionizing Radiation (LNMRI), Rio de Janeiro, (Brazil); Cassette, P. [Laboratoire National Henri Becquerel (LNE-LNHB), Paris, (France); Dewey, M.S. [National Institute of Standards and Technology (NIST), Gaithersburg, MD, (United States); Moiseev, N.N.; Kharitonov, I.A. [D I Mendeleyev Institute for Metrology (VNIIM), St Petersburg, (Russian Federation)

    2011-07-01

    Section III (neutron measurements) of the Comite Consultatif des Rayonnements Ionisants, CCRI, conducted a key comparison of primary measurements of the neutron emission rate of an {sup 241}Am-Be({alpha},n) radionuclide source. A single {sup 241}Am-Be({alpha},n) source was circulated to all the participants between 1999 and 2005. Eight laboratories participated - the CIAE (China), CMI (Czech Republic), KRISS (Republic of Korea), LNMRI (Brazil), LNE-LNHB (France), NIST (USA), NPL (UK) and the VNIIM (Russian Federation) - with the NPL making their measurements at the start and repeating them near the end of the exercise to verify the stability of the source. Each laboratory reported the emission rate into 4{pi} sr together with a detailed uncertainty budget. All participants used the manganese bath technique, with the VNIIM also making measurements using an associated particle technique. The CMI, KRISS, VNIIM, and later the NPL, also measured the anisotropy of the source although this was not a formal part of the comparison. The first draft report was released in May 2006 and having been discussed and modified by the participants and subsequently reviewed by the CCRI(III), the present paper is now the final report of the comparison. (authors)

  6. Thermal Emission of Alkali Metal Ions from Al30-Pillared Montmorillonite Studied by Mass Spectrometric Method

    Directory of Open Access Journals (Sweden)

    V. B. Motalov

    2017-01-01

    Full Text Available The thermal emission of alkali metal ions from Al30-pillared montmorillonite in comparison with its natural form was studied by mass spectrometry in the temperature range 770–930 K. The measurements were carried out on a magnetic mass spectrometer MI-1201. For natural montmorillonite, the densities of the emission currents (j decrease in the mass spectrum in the following sequence (T = 805 K, A/cm2: K+ (4.55 · 10−14, Cs+ (9.72 · 10−15, Rb+ (1.13 · 10−15, Na+ (1.75 · 10−16, Li+ (3.37 · 10−17. For Al30-pillared montmorillonite, thermionic emission undergoes temperature-time changes. In the low-temperature section of the investigated range (770–805 K, the value of j increases substantially for all ions in comparison with natural montmorillonite (T = 805 K, A/cm2: Cs+ (6.47 · 10−13, K+ (9.44 · 10−14, Na+ (3.34 · 10−15, Rb+ (1.77 · 10−15, and Li+ (4.59 · 10−16. A reversible anomaly is observed in the temperature range 805–832 K: with increasing temperature, the value of j of alkaline ions falls abruptly. This effect increases with increasing ionic radius of M+. After a long heating-up period, this anomaly disappears and the lnj-1/T dependence acquires a classical linear form. The results are interpreted from the point of view of the dependence of the efficiency of thermionic emission on the phase transformations of pillars.

  7. Evaluation of the 40 K internal exposure on the inhabitants of Rio de Janeiro city, Brazil

    International Nuclear Information System (INIS)

    Santos, Eliane E.; Lauria, Dejanira C.; Amaral, Eliana C.S.; Carvalho, Laercio L.

    2002-01-01

    Among the naturally occurring radionuclides 40 K is the highest contributor for the intake dose. The aiming of this research was to determine the activity concentrations of 40 K in the main consumed foodstuffs by the adult inhabitants of Rio de Janeiro city in view of estimating its daily intake and arisen intake dose. The 40 K activity concentrations in the foodstuffs ranged from 20 to 544 Bq/kg fresh and the estimated daily intake was 61 Bq. The highest contribution for its intake arises from consumption of bean (35%), beef (11%), potato (8%) and rice (8%). The total annual effective dose was estimated to be 138 mSv/a. Value that falls into the range of international literature reported value (from 122 to 200 μSv/a. (author)

  8. Closing in on the K Edge : Coronary CT Angiography at 100, 80, and 70 kV-Initial Comparison of a Second-versus a Third-Generation Dual-Source CT System

    NARCIS (Netherlands)

    Meyer, Mathias; Haubenreisser, Holger; Schoepf, U. Joseph; Vliegenthart, Rozemarijn; Leidecker, Christianne; Allmendinger, Thomas; Lehmann, Ralf; Sudarski, Sonja; Borggrefe, Martin; Schoenberg, Stefan O.; Henzler, Thomas

    2014-01-01

    Purpose: To prospectively evaluate radiation and contrast medium requirements for performing high-pitch coronary computed tomographic (CT) angiography at 70 kV using a third-generation dual-source CT system in comparison to a second-generation dual-source CT system. Materials and Methods: All

  9. FALSIRE Phase II. CSNI project for Fracture Analyses of Large-Scale International Reference Experiments (Phase II). Comparison report

    International Nuclear Information System (INIS)

    Sievers, J.; Schulz, H.; Bass, R.; Pugh, C.; Keeney, J.

    1996-11-01

    A summary of Phase II of the Project for Fracture Analysis of Large-Scale International Reference Experiments (FALSIRE) is presented. A FALSIRE II Workshop focused on analyses of reference fracture experiments. More than 30 participants representing 22 organizations from 12 countries took part in the workshop. Final results for 45 analyses of the reference experiments were received from the participating analysts. For each experiment, analysis results provided estimates of variables that include temperature, crack-mouth-opening displacement, stress, strain, and applied K and J values. The data were sent electronically to the Organizing Committee, who assembled the results into a comparative data base using a special-purpose computer program. A comparative assessment and discussion of the analysis results are presented in the report. Generally, structural responses of the test specimens were predicted with tolerable scatter bands. (orig./DG)

  10. New metastable form of glibenclamide prepared by redispersion from ternary solid dispersions containing polyvinylpyrrolidone-K30 and sodium lauryl sulfate.

    Science.gov (United States)

    Thongnopkoon, Thanu; Puttipipatkhachorn, Satit

    2016-01-01

    Modification of polymorphic forms of poorly water-soluble drugs is one way to achieve the desirable properties. In this study, glibenclamide (GBM) particles with different polymorphic forms, including a new metastable form, were obtained from redispersion of ternary solid dispersion systems. The ternary solid dispersion systems, consisting of GBM, polyvinylpyrrolidone-K30 (PVP-K30) and sodium lauryl sulfate (SLS), were prepared by solvent evaporation method and subsequently redispersed in deionized water. The precipitated drug particles were then collected at a given time period. The drug particles with different polymorphic forms could be achieved depending on the polymer/surfactant ratio. Amorphous drug nanoparticles could be obtained by using a high polymer/surfactant ratio, whereas two different crystalline forms were obtained from the systems containing low polymer/surfactant ratios. Interestingly, a new metastable form IV of GBM with improved dissolution behavior could be obtained from the system of GBM:PVP-K30:SLS with the weight ratio of 2:2:4. This new polymorphic form IV of GBM was confirmed by differential scanning calorimetry (DSC), Fourier transform infrared (FT-IR) spectroscopy, powder X-ray diffractometry (PXRD) and solid state 13 C nuclear magnetic resonance (NMR) spectroscopy. The molecular arrangement of the new polymorphic form IV of GBM was proposed. The GBM particles with polymorphic form IV also showed an improved dissolution behavior. In addition, it was found that the formation of the new polymorphic form IV of GBM by this process was reproducible.

  11. Can international safety overcome national prejudice

    International Nuclear Information System (INIS)

    Thomas, S.

    1986-01-01

    Following the accident at the Chernobyl nuclear power plant, a proposal has been made that the International Atomic Energy Agency (IAEA) should carry out a programme of reactor assessments and inspections to ensure that the plant is competently run. The 13 proposals for improving safety that arose from the recent IAEA meeting in Vienna about the events at Chernobyl are listed. They also propose international collaboration on many points. This article draws attention to the difficulties in achieving international cooperation. Comparison is made with the case of international air and marine transport and an attempt to get an agreement to reduce emissions of acid rain precursors by 30%. The essential requirements for international regulation are stated. Four specific activities that could be covered are discussed. These are inspection of operating plant, enforcement of minimum standards for routine emissions, establishment of design standards and establishment of post-accident procedures for international co-operation. (UK)

  12. K+-nucleus interaction

    International Nuclear Information System (INIS)

    Gibbs, W.R.

    1984-01-01

    The K + -nucleus system is reviewed and comparison with data is made. The principal conclusions are that the theoretical uncertainties in relating the K + -nucleus interaction to the K + -nucleon interaction are very small and hence the positive kaon makes an excellent probe of the nucleus. It is suggested that this particle may be more sensitive to non-nucleonic degrees of freedom (especially quarks) than classical probes

  13. Malé osobnosti veľkých dejín – veľké osobnosti malých dejín IV. Príspevky k hudobnej regionalistike, Slovenské národné múzeum – Hudobné múzeum, Brämerova kúria, Bratislava 30. listopadu – 1. prosince 2017

    Czech Academy of Sciences Publication Activity Database

    Kachlík, Jan

    2018-01-01

    Roč. 55, č. 1 (2018), s. 102-104 ISSN 0018-7003. [Malé osobnosti veľkých dejín – veľké osobnosti malých dejín IV. Príspevky k hudobnej regionalistike. Bratislava, 30.11.2017-01.12.2017] Institutional support: RVO:68378076 Keywords : music ology * conference Subject RIV: AL - Art, Architecture, Cultural Heritage OBOR OECD: Performing arts studies ( Music ology, Theater science, Dramaturgy)

  14. Itaalia parlamendi saadikutekoja välissuhete ja euroasjade komisjoni esimehe hr Gustavo Selva kõne / Gustavo Selva

    Index Scriptorium Estoniae

    Selva, Gustavo

    2003-01-01

    Ilmunud ka: Proceedings of the 9th international conference "Estonia and the European Union: Estonia on its way to a changing Europe" : October 30-November 1, 2002, Tallinn, Estonian National Library. - Tallinn, lk. 66-69. Autori kõne plenaaristungil "Euroopa silmitsi uute üleilmsete julgeolekuväljakutsetega", kus ta väidab, et Euroopa julgeoleku kõige tähtsamaks elemendiks on Euroopa ise

  15. Internalization of Rat FSH and LH/CG Receptors by rec-eCG in CHO-K1 Cells.

    Science.gov (United States)

    Park, Jong-Ju; Seong, Hun-Ki; Kim, Jeong-Soo; Munkhzaya, Byambaragchaa; Kang, Myung-Hwa; Min, Kwan-Sik

    2017-06-01

    Equine chorionic gonadotropin (eCG) is a unique molecule that elicits the response characteristics of both follicle-stimulating hormone (FSH) and luteinizing hormone (LH) in other species. Previous studies from this laboratory had demonstrated that recombinant eCG (rec-eCG) from Chinese hamster ovary (CHO-K1) cells exhibited both FSH- and LH-like activity in rat granulosa and Leydig cells. In this study, we analyzed receptor internalization through rec-eCGs, wild type eCG (eCGβ/α) and mutant eCG (eCGβ/αΔ56) with an N-linked oligosaccharide at Asn 56 of the α-subunit. Both the rec-eCGs were obtained from CHO-K1 cells. The agonist activation of receptors was analyzed by measuring stimulation time and concentrations of rec-eCGs. Internalization values in the stably selected rat follicle-stimulating hormone receptor (rFSHR) and rat luteinizing/chorionic gonadotropin receptor (rLH/CGR) were highest at 50 min after stimulation with 10 ng of rec-eCGβ/α. The dose-dependent response was highest when 10 ng of rec-eCGβ/α was used. The deglycosylated eCGβ/αΔ56 mutant did not enhance the agonist-stimulated internalization. We concluded that the state of activation of rFSHR and rLH/CGR could be modulated through agonist-stimulated internalization. Our results suggested that the eLH/CGRs are mostly internalized within 60 min by agonist-stimulation by rec-eCG. We also suggested that the lack of responsiveness of the deglycosylated eCGβ/ αΔ56 was likely because the site of glycosylation played a pivotal role in agonist-stimulated internalization in cells expressing rFSHR and rLH/CGR.

  16. High power cable with internal water cooling 400 kV

    Science.gov (United States)

    Rasquin, W.; Harjes, B.

    1982-08-01

    Due to the concentration of electricity production in large power plants, the need of higher power transmissions, and the protection of environment, developement of a 400 kV water cooled cable in the power range of 1 to 5 GVA was undertaken. The fabrication and testing of equipment, engineering of cable components, fabrication of a test cable, development of cable terminal laboratory, testing of test cable, field testing of test cable, fabrication of industrial cable laboratory, testing of industrial cable, field testing of industrial cable, and system analysis for optimization were prepared. The field testing was impossible to realize. However, it is proved that a cable consisting of an internal stainless steel water cooled tube, covered by stranded copper profiles, insulated with heavy high quality paper, and protected by an aluminum cover can be produced, withstand tests accordingly to IEC/VDE recommendations, and is able to fulfill all exploitation conditions.

  17. Characteristics and clinical correlates of MPL 515W>L/K mutation in essential thrombocythemia.

    Science.gov (United States)

    Vannucchi, Alessandro M; Antonioli, Elisabetta; Guglielmelli, Paola; Pancrazzi, Alessandro; Guerini, Vittoria; Barosi, Giovanni; Ruggeri, Marco; Specchia, Giorgina; Lo-Coco, Francesco; Delaini, Federica; Villani, Laura; Finotto, Silvia; Ammatuna, Emanuele; Alterini, Renato; Carrai, Valentina; Capaccioli, Gloria; Di Lollo, Simonetta; Liso, Vincenzo; Rambaldi, Alessandro; Bosi, Alberto; Barbui, Tiziano

    2008-08-01

    Among 994 patients with essential thrombocythemia (ET) who were genotyped for the MPLW515L/K mutation, 30 patients carrying the mutation were identified (3.0%), 8 of whom also displayed the JAK2V671F mutation. MPLW515L/K patients presented lower hemoglobin levels and higher platelet counts than did wild type (wt) MPL; these differences were highly significant compared with MPLwt/JAK2V617F-positive patients. Reduced hemoglobin and increased platelet levels were preferentially associated with the W515L and W515K alleles, respectively. MPL mutation was a significant risk factor for microvessel disturbances, suggesting platelet hyperreactivity associated with constitutively active MPL; arterial thromboses were increased only in comparison to MPLwt/JAK2wt patients. MPLW515L/K patients presented reduced total and erythroid bone marrow cellularity, whereas the numbers of megakaryocytes, megakaryocytic clusters, and small-sized megakaryocytes were all significantly increased. These data indicate that MPLW515L/K mutations do not define a distinct phenotype in ET, although some differences depended on the JAK2V617F mutational status of the counterpart.

  18. Evolution of deceased organ donation activity vs. efficiency over a 15 year period: an international comparison.

    Science.gov (United States)

    Weiss, Julius; Elmer, Andreas; Mahíllo, Beatriz; Domínguez-Gil, Beatriz; Avsec, Danica; Costa, Alessandro Nanni; Haase-Kromwijk, Bernadette J J M; Laouabdia, Karim; Immer, Franz F

    2018-04-19

    The donation rate (DR) per million population is not ideal for an efficiency comparison of national deceased organ donation programs. The DR does not account for variabilities in the potential for deceased donation which mainly depends on fatalities from causes leading to brain death. In this study, the donation activity was put into relation to the mortality from selected causes. Based on that metric, this study assesses the efficiency of different donation programs. This is a retrospective analysis of 2001-2015 deceased organ donation and mortality registry data. Included are 27 Council of Europe countries, as well as the USA. A donor conversion index (DCI) was calculated for assessing donation program efficiency over time and in international comparisons. According to the DCI and of the countries included in the study, Spain, France, and the USA had the most efficient donation programs in 2015. Even though mortality from the selected causes decreased in most countries during the study period, differences in international comparisons persist. This indicates that the potential for deceased organ donation and its conversion into actual donation is far from being similar internationally. Compared with the DR, the DCI takes into account the potential for deceased organ donation, and therefore is a more accurate metric of performance. National donation programs could optimize performance by identifying the areas where most potential is lost, and by implementing measures to tackle these issues.

  19. Entropic and algebraic K-systems: A comparison

    International Nuclear Information System (INIS)

    Benatti, F.

    1990-01-01

    In the quantum, i.e. non-commutative case, algebraic K-systems and entropic K-systems must be distinguished. The similarities and differences between them are considered, especially with regard to clustering- and mixing properties. 14 refs

  20. Determining the k in k-means with MapReduce

    OpenAIRE

    Debatty , Thibault; Michiardi , Pietro; Mees , Wim; Thonnard , Olivier

    2014-01-01

    International audience; In this paper we propose a MapReduce implementation of G-means, a variant of k-means that is able to automatically determine k, the number of clusters. We show that our implementation scales to very large datasets and very large values of k, as the computation cost is proportional to nk. Other techniques that run a clustering algorithm with different values of k and choose the value of k that provides the " best " results have a computation cost that is proportional to...

  1. Quantitative measurement of membrane Na+-K+ ATPase activity using thallium-201: comparison with rubidium-86

    International Nuclear Information System (INIS)

    Lee, Jae Tae; Shon, Sang Kyun; Lee, Kyu Bo; Lee, In Kyu

    1998-01-01

    Na + -K + ATPase activity has been estimated by the degree of inhibition of cation transport by cardiac glycosides (ouabain) using Rb-86 as a substrate. The biological characteristics of Tl-201 is known to be similar to those of potassium as a transport substrate in the presence of glucose, insulin or phobol myristate acetate (PMA). The purpose of this study was to measure ouabain sensitive Na + -K + ATPase activity using Tl-201 and compare with that using Rb-86. Smooth muscle cells isolated from rat aorta or human placental umbilical artery were cultured, and used to measure cellular Na + -K + ATPase activity. Na + -K + ATPase activity was measured as a percentage decrease in cellular uptake of Tl-201 or Rb-86 by ouabain under the presence of glucose, insulin or PMA in media. Na + -K + ATPase activity measured with Tl-201, as a transport substrate, was not different from those measured with Rb-86 in rat or human smooth muscle cell preparation. Incubation with high concentration glucose resulted in about 30% decrease in enzyme activity. In contrast, insulin or PMA resulted in 50-70% or 28% increase from baseline activity, respectively. These results suggests that Tl-201 could replace Rb-86 in measurement of ouabain sensitive Na + -K + ATPase activity in vitro. High level of glucose concentration decreased cellular Na + -K + ATPase activity, but insulin or PMA increased it

  2. Residents examine factors associated with 30-day, same-cause hospital readmissions on an internal medicine service.

    Science.gov (United States)

    Moran, Jennifer; Colbert, Colleen Y; Song, Juhee; Hull, Joshua; Rajan, Sabitha; Varghees, Sunita; Arroliga, Alejandro C; Reddy, Santosh P

    2013-01-01

    In recent years, there has been increased interest in stemming the tide of hospital readmissions in an attempt to improve quality of care. This study presents the Phase I results of a resident-led quality improvement initiative to determine the percentage of and risk factors for same-cause readmissions (SCRs; defined as hospital readmission within 30 days of hospital discharge for treatment of the same condition) to the internal medicine service of a multispecialty teaching hospital in central Texas. Results indicate that patients diagnosed with chronic obstructive pulmonary disease/asthma or anemia may be at increased risk for SCRs. Those patients who are insured by Medicaid and those who require assistance from social services also demonstrated an increased risk for SCRs. This study appears to be the first resident-led initiative in the field to examine 30-day SCRs to an internal medicine service for demographic and clinical risk factors.

  3. Work-Related Attitudes of Czech Generation Z: International Comparison

    Directory of Open Access Journals (Sweden)

    Jaroslava Kubátová,

    2016-12-01

    Full Text Available The goal of this article is to present work-related attitudes of a sample of Czech Generation Z and their comparison to the results of an international research study. Currently, there are three important trends influencing the labor market: (1 the origin and development of a ubiquitous working environment, (2 the thriving of coworking centers, and (3 Generation Z's entering the labor market. Instead of traditional jobs, the bearers of human capital tend to choose independent work in an online environment, and often work in coworking centers. Using self-determination theory, we substantiate why they thrive better this way. Based on the results of an international research project focused on work attitudes among Generation Z and the results of a replication study we carried out in the Czech Republic, we attest that members of Generation Z may prefer independent virtual work in coworking centers, too. The total amount of available human capital, the lack of which is pointed out by companies, may grow thanks to new ways of working. Companies, which can use human capital of independent workers, gain a competitive advantage.

  4. Final report on EURAMET.T-K6.1: Bilateral comparison of the realisations of local dew/frost-point temperature scales in the range -70 °C to +20 °C

    Science.gov (United States)

    Heinonen, Martti; Zvizdic, Davor; Sestan, Danijel

    2013-01-01

    As the European extension of the first CCT humidity key comparison, EUROMET.T-K6 was successfully completed in year 2008. After this comparison, a new low dew-point generator was introduced at LPM in Croatia as a result of progress in the EUROMET P912 project. With this new facility, the LPM uncertainties decreased significantly and the operating range became significantly wider. Therefore, it was decided to arrange a bilateral comparison between LPM and MIKES in Finland providing a link to EUROMET.T-K6 and CCT-K6. This comparison was carried out in a manner similar to other K6 comparisons but only one transfer standard was used instead of two units and the measurement point -70 °C was added to the measurement scheme. At all measurement points, the bilateral equivalence was well within the estimated expanded uncertainty at the approximately 95% confidence level. Also, the deviations of the LPM results from the EUROMET.T-K6 reference values were smaller than their expanded uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Standardization of the 192Ir within the framework of an international comparison

    International Nuclear Information System (INIS)

    Iwahara, A.; Delgado, J.U.; Silva, T.A. da

    1998-01-01

    In 1997, six national metrology laboratories of several countries, including the Laboratorio Nacional de Metrologias das Radiacoes Ionizantes (LNMRI), participated of an international comparison of activity concentration measurements of a 1 92 I r solution. The measuring method used by LNMRI was the 4 ΠΒ-Γ absolute coincidence counting. Other indirect methods such as germanium detector spectroemtry and 4 ΠΓ ionization chamber used in order to check the absolute measurement. The reported results by the participant laboratories showed good agreeement and the metrological traceability to Bureau International des Poids et Mesures was established for the activity measurements of 1 92 I r. The half time was also determined following its decay by using the 4 4 ΠΓ ionization chambers

  6. KEY COMPARISONS: Final report: SIM regional comparison of ac-dc voltage transfer difference (SIM.EM.K6a, SIM.EM-K9 and SIM.EM-K11)

    Science.gov (United States)

    Campos, Sara; Filipski, Piotr; Izquierdo, Daniel; Afonso, Edson; Landim, Régis P.; Di Lillo, Lucas; Lipe, Thomas

    2009-01-01

    Three comparisons of ac-dc voltage transfer difference held from January to December 2004 are reported. Six NMIs in the SIM region took part: NRC (Canada), NIST (United States of America), CENAM (Mexico), INTI (Argentina), UTE (Uruguay) and INMETRO (Brazil). The comparisons were proposed to assess the measurement capabilities in ac-dc voltage transfer difference of the NMIs in the SIM region. The test points were selected to link the results with the equivalent CCEM Key Comparisons, through three NMIs participating in both SIM and CCEM key comparisons. Additionally, a SIM.EM-Supplementary comparison was proposed, in support of the SIM NMIs' power/energy meter calibration capabilities. One technical protocol and one travelling standard were used, to economize on time and resources. The report shows the degree of equivalence in the SIM region and also the degree of equivalence with the corresponding CCEM reference value. The results of all participants support the values and uncertainties of the applicable CMC entries for ac-dc voltage transfer difference in the Key Comparison Database held at the BIPM. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  7. High precision simple interpolation asynchronous FIFO based on ACEX1K30 for HIRFL-CSRe

    International Nuclear Information System (INIS)

    Li Guihua; Qiao Weimin; Jing Lan

    2008-01-01

    High precision simple interpolation asynchronous FIFO of HIRFL-CSRe was developed based on the ACEX1K30 FPGA in VHDL Hardware Description language. The FIFO runs in FPGA of DSP module of HIRFL-CSRe. The input data of FIFO is from DSP data bus and the output data is to DAC data bus. It's kernel adopts double buffer ping-pong mode and it can implement simple interpolation inside FPGA. The module can control out- put data time delay in 40 ns. The experimental results indicate that this module is practical and accurate to HIRFL-CSRe. (authors)

  8. On the nature of low temperature internal friction peaks in metallic glasses

    NARCIS (Netherlands)

    Khonik, VA; Spivak, LV

    Low temperature (30 K) internal friction in a metallic glass Ni60Nb40 subjected to preliminary inhomogeneous deformation by cold rolling, homogeneous tensile deformation or electrolytic charging with hydrogen is investigated. Cold rolling or hydrogenation result in appearance of similar

  9. Update of the BIPM.RI(II)-K1.Tc-99m comparison of activity measurements for the radionuclide {sup 99m}Tc to include new results for the LNE-LNHB and the NPL

    Energy Technology Data Exchange (ETDEWEB)

    Michotte, C.; Courte, S.; Ratel, G. [Bureau International des Poids et Mesures (BIPM), 92 - Sevres (France); Moune, M. [LNE-LNHB, Laboratoire national de metrologie et d' essais-Laboratoire National Henri Becquerel, Gif sur Yvette (France); Johansson, L.; Keightley, J. [National Physical Laboratory (NPL), Middlesex (United Kingdom)

    2010-12-15

    In 2007 and 2008 respectively, the Laboratoire national de metrologie et d'essais -Laboratoire national Henri Becquerel (LNE-LNHB), France and the National Physical Laboratory (NPL), UK, submitted ampoules with between 10 MBq and 130 MBq activity of {sup 99m}Tc to the International Reference System (SIR), to update their results in the BIPM.RI(II)-K1.Tc-99m comparison. Together with the four other national metrology institutes (NMI) that are participants, thirteen samples have been submitted since 1983. The key comparison reference value (KCRV) has been recalculated to include the latest primary results of the PTB and the LNE-LNB as this makes the evaluation more robust. The degrees of equivalence between each equivalent activity measured in the SIR are given in the form of a matrix for all six NMIs. A graphical presentation is also given. (authors)

  10. Baseline quantity of 131I, 137Cs, 134Cs and 40K in urinary excretions from Thai people and internal exposure dose

    Science.gov (United States)

    Peekhunthod, D.; Bangvirunrak, J.; Sansakon, S.; Nukultham, A.; Pukkhaw, T.

    2017-06-01

    Today, sealed and unsealed radioactive materials have been used in Thailand for various purposes such as medical, agricultural and industrial applications. There is a growing trend in the use of radioactive materials. Moreover, neighboring countries are planning to construct and operate nuclear power plants. In case of nuclear power plant accidents, radioactive releases in environment and intakes into human body by inhalation and ingestion causing long term health effects. This research aims to determine the radiation baseline quantity of interested relevant radionuclides such as 131I, 137Cs, 134Cs as well as a natural radionuclide, 40K in urine samples of Thai people by gamma spectrometry. Two types of detectors (NaI and HpGe detectors) are calibrated by mixed radionuclide standards of 109Cd, 57Co, 133Ba, 54Mn, 137Cs and 60Co, (energy range from 88 to 1,331 keV). 720 urine samples are collected over a 24 hour period from Thai volunteers with the age older than 18 years old, who lived in eight locations of Thailand. To reduce the effect of geometric difference, 30 ml of urine samples are prepared for counting measurement and efficiency determination. The radiation baseline quantity of 131I, 137Cs, 134Cs and 40K in 30 ml of urine samples are 0.37±0.09, 0.63±0.13, 0.39±0.08 and 7.84±1.63 Bq, respectively. Based on the assumption of intake (50% of the intake by ingestion and 50% of the intake by inhalation), internal dose for members of public are assessed. The committed dose equivalent due to an intake of 131I, 137Cs, 134Cs and 40K are 2.36E-03±1.66-03, 1.15E-01±8.61E-02, 1.16E-01±7.77E-02, 9.44E-01±3.56E-01 mSv per year, respectively.

  11. The Multitheoretical List of Therapeutic Interventions - 30 items (MULTI-30).

    Science.gov (United States)

    Solomonov, Nili; McCarthy, Kevin S; Gorman, Bernard S; Barber, Jacques P

    2018-01-16

    To develop a brief version of the Multitheoretical List of Therapeutic Interventions (MULTI-60) in order to decrease completion time burden by approximately half, while maintaining content coverage. Study 1 aimed to select 30 items. Study 2 aimed to examine the reliability and internal consistency of the MULTI-30. Study 3 aimed to validate the MULTI-30 and ensure content coverage. In Study 1, the sample included 186 therapist and 255 patient MULTI ratings, and 164 ratings of sessions coded by trained observers. Internal consistency (Chronbach's alpha and McDonald's omega) was calculated and confirmatory factor analysis was conducted. Psychotherapy experts rated content relevance. Study 2 included a sample of 644 patient and 522 therapist ratings, and 793 codings of psychotherapy sessions. In Study 3, the sample included 33 codings of sessions. A series of regression analyses was conducted to examine replication of previously published findings using the MULTI-30. The MULTI-30 was found valid, reliable, and internally consistent across 2564 ratings examined across the three studies presented. The MULTI-30 a brief and reliable process measure. Future studies are required for further validation.

  12. K C Mittal

    Indian Academy of Sciences (India)

    K C Mittal. Articles written in Sadhana. Volume 30 Issue 6 December 2005 pp 757-764. Development of a 300-kV Marx generator and its application to drive a relativistic electron beam · Y Choyal Lalit Gupta Preeti Vyas Prasad Deshpande Anamika Chaturvedi K C Mittal K P Maheshwari · More Details Abstract Fulltext PDF.

  13. Comparison of kDNA PCR-hybridization assay with three PCR methods for canines visceral Leishmaniasis diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Pilatti, Marcia M.; Andrade, Antero S.R. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)], e-mail: marciapilatti@yahoo.com.br, e-mail: antero@cdtn.br; Ferreira, Sidney A. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Parasitologia], e-mail: saninoalmeida@gmail.com

    2009-07-01

    The sensitivity of the kDNA PCR-Hybridization assay, which uses radioactive DNA probes (labeled with {sup 32}P), was compared with three conventional PCR methods used for canine visceral leishmaniasis diagnosis. All PCR methods had two steps: a first amplification followed by hybridization or by a new amplification (nested or semi nested). Two methods (kDNA PCR-Hybridization and kDNA snPCR) used primers addressed to kinetoplast minicircles and the other two methods to the coding (LnPCR) and intergenic noncoding regions (ITS-1 nPCR) of the ribosomal rRNA genes. The comparison was accomplished in two groups of 23 infected dogs using samples collected by the conjunctival swab procedure. In the Group 1 the DNA was extracted from cotton swabs by phenol-chloroform and in Group 2 by boiling. The most efficient PCR methods in the Group 1 were those based on kDNA targets. The kDNA PCR-Hybridization was able to detect parasites in 22/23 dogs (95.6%) and in 40/46 samples (86.9%). The kDNA snPCR was positive for 21/23 dogs (91.3%) and for 40/46 samples (86.9%). The positivities of the kDNA based methods were significantly higher than the positivities verified for the methods based on ribosomal rRNA genes (p<0.05). In the Group 2 the kDNA PCR- Hybridization showed a better performance detecting parasites in 18/23 dogs (78.3%) and in 31/46 samples (67.4%), significantly higher than the other three methods (p<0.05). The higher sensitivity of the minicircle kDNA based assays reported by others was confirmed in this study and kDNA PCR-Hybridization showed the best sensitivity among the assays evaluated. (author)

  14. Comparison of kDNA PCR-hybridization assay with three PCR methods for canines visceral Leishmaniasis diagnosis

    International Nuclear Information System (INIS)

    Pilatti, Marcia M.; Andrade, Antero S.R.; Ferreira, Sidney A.

    2009-01-01

    The sensitivity of the kDNA PCR-Hybridization assay, which uses radioactive DNA probes (labeled with 32 P), was compared with three conventional PCR methods used for canine visceral leishmaniasis diagnosis. All PCR methods had two steps: a first amplification followed by hybridization or by a new amplification (nested or semi nested). Two methods (kDNA PCR-Hybridization and kDNA snPCR) used primers addressed to kinetoplast minicircles and the other two methods to the coding (LnPCR) and intergenic noncoding regions (ITS-1 nPCR) of the ribosomal rRNA genes. The comparison was accomplished in two groups of 23 infected dogs using samples collected by the conjunctival swab procedure. In the Group 1 the DNA was extracted from cotton swabs by phenol-chloroform and in Group 2 by boiling. The most efficient PCR methods in the Group 1 were those based on kDNA targets. The kDNA PCR-Hybridization was able to detect parasites in 22/23 dogs (95.6%) and in 40/46 samples (86.9%). The kDNA snPCR was positive for 21/23 dogs (91.3%) and for 40/46 samples (86.9%). The positivities of the kDNA based methods were significantly higher than the positivities verified for the methods based on ribosomal rRNA genes (p<0.05). In the Group 2 the kDNA PCR- Hybridization showed a better performance detecting parasites in 18/23 dogs (78.3%) and in 31/46 samples (67.4%), significantly higher than the other three methods (p<0.05). The higher sensitivity of the minicircle kDNA based assays reported by others was confirmed in this study and kDNA PCR-Hybridization showed the best sensitivity among the assays evaluated. (author)

  15. Qualitative content analysis for international comparison of data usage agreements

    Directory of Open Access Journals (Sweden)

    Christian Haux

    2017-04-01

    Undertaking an overview of privacy conditions can be a valuable step in comparing privacy and security requirements in different national regulations. The qualitative content analysis was found a suitable approach for this purpose because it enables the detection of fine characteristics. By using an incremental design, it is possible to adapt the coding system to include additional partners. However, the current coding system has the limitation that heterogeneity between the agreements leads to a fine granularity of categories that hamper the comparability between partners. Despite these problems, the approach allows the comparison of data privacy and supports the development of a data integration process for international harmonisation.

  16. Final report on key comparison APMP.M.P-K3: Absolute pressure measurements in gas from 3 × 10-6 Pa to 9 × 10-4 Pa

    Science.gov (United States)

    Yoshida, H.; Arai, K.; Akimichi, H.; Hong, S. S.; Song, H. W.

    2011-01-01

    The results of a key comparison of ultra-high vacuum standards at two national metrology institutes (NMIJ/AIST and KRISS) are reported. This bilateral comparison was carried out from May 2010 to October 2010 within the framework of the Asia-Pacific Metrology Programme (APMP) to determine their degrees of equivalence at pressures in the range from 3 × 10-6 Pa to 9 × 10-4 Pa. The pilot institute was NMIJ/AIST. Two spinning rotor gauges and two hot cathode ionization gauges were used as the transfer standards. NMIJ/AIST used two calibration systems: the dynamic expansion system (NMIJ-DES) and two-stage flow-dividing system (NMIJ-TFS). KRISS used the dynamic expansion system. The transfer standards were sufficiently stable to meet the requirements of the comparison compared with those of previous international comparisons owing to some improvements of the protocol and the transfer standards. The ultra-high vacuum standards of NMIJ/AIST and KRISS were found to be equivalent within their claimed uncertainties in the range from 3 × 10-6 Pa to 9 × 10-5 Pa. The NMIJ-DES results, which have smaller uncertainty than NMIJ-TFS, were transferred to the corresponding CCM key comparison, CCM.P-K3, in the range from 3 × 10-6 Pa to 9 × 10-5 Pa and it is shown that the NMIJ values were equivalent to the CCM key comparison reference value within the claimed uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  17. S K Date

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. S K Date. Articles written in Bulletin of Materials Science. Volume 23 Issue 2 April 2000 pp 97-101 Magnetic Materials. Comparison of the irreversible thermomagnetic behaviour of some ferro- and ferrimagnetic systems · P S Anil Kumar P A Joy S K Date · More Details Abstract ...

  18. Comparison of ICRP Publication 30 lung model-based predictions with measured bioassay data for airborne natural UO2 exposure

    International Nuclear Information System (INIS)

    Thind, K.S.

    1987-01-01

    In this paper a comparison is made between the build-up of U thorax burdens and the predicted total lung (lung and lymph) burden, based on the lung model provided in ICRP Publication 30 for a group of 29 atomic radiation workers at a Canadian fuel fabrication facility. A similar comparison is made between the predicted ratio of the total lung burden to urinary excretion and the ratio obtained from bioassay data. The study period for the comparison is 5 y. The inhalation input for the lung model calculations was derived from air-sampling data and the choice of particle size activity median aerodynamic diameter (AMAD) was guided by particle size measurements made at representative work locations. The pulmonary clearance half-times studied were 100, 250 and 500 d. For the purpose of this comparison, averaged exposure and averaged bioassay data for the group were used. This comparison indicates that for the conditions of this facility, the assumption of a 500-d pulmonary clearance half-time and a particle size of 1 micron (AMAD) may be too conservative. It is suggested that measurements of air concentrations and particle size used as input parameters for the ICRP Publication 30 lung model may be used to calculate bioassay parameters which may then be tested against bioassay data obtained as part of an operational health physics program, thereby giving a useful step towards defining a derived air concentration value for U in the workplace

  19. Student and School Factors Affecting Mathematics Achievement: International Comparisons between Korea, Japan and the USA

    Science.gov (United States)

    Shin, Jongho; Lee, Hyunjoo; Kim, Yongnam

    2009-01-01

    The purpose of the study was to comparatively investigate student- and school-level factors affecting mathematics achievement of Korean, Japanese and American students. For international comparisons, the PISA 2003 data were analysed by using the Hierarchical Linear Modeling method. The variables of competitive-learning preference, instrumental…

  20. Analysis of the OECD main steam line break benchmark using ANC-K/MIDAC code

    International Nuclear Information System (INIS)

    Aoki, Shigeaki; Tahara, Yoshihisa; Suemura, Takayuki; Ogawa, Junto

    2004-01-01

    A three-dimensional (3D) neutronics and thermal-and-hydraulics (T/H) coupling code ANC-K/MIDAC has been developed. It is the combination of the 3D nodal kinetic code ANC-K and the 3D drift flux thermal hydraulic code MIDAC. In order to verify the adequacy of this code, we have performed several international benchmark problems. In this paper, we show the calculation results of ''OECD Main Steam Line Break Benchmark (MSLB benchmark)'', which gives the typical local power peaking problem. And we calculated the return-to-power scenario of the Phase II problem. The comparison of the results shows the very good agreement of important core parameters between the ANC-K/MIDAC and other participant codes. (author)

  1. Effect of the Solvent Temperatures on Dynamics of Serine Protease Proteinase K

    Directory of Open Access Journals (Sweden)

    Peng Sang

    2016-02-01

    Full Text Available To obtain detailed information about the effect of the solvent temperatures on protein dynamics, multiple long molecular dynamics (MD simulations of serine protease proteinase K with the solute and solvent coupled to different temperatures (either 300 or 180 K have been performed. Comparative analyses demonstrate that the internal flexibility and mobility of proteinase K are strongly dependent on the solvent temperatures but weakly on the protein temperatures. The constructed free energy landscapes (FELs at the high solvent temperatures exhibit a more rugged surface, broader spanning range, and higher minimum free energy level than do those at the low solvent temperatures. Comparison between the dynamic hydrogen bond (HB numbers reveals that the high solvent temperatures intensify the competitive HB interactions between water molecules and protein surface atoms, and this in turn exacerbates the competitive HB interactions between protein internal atoms, thus enhancing the conformational flexibility and facilitating the collective motions of the protein. A refined FEL model was proposed to explain the role of the solvent mobility in facilitating the cascade amplification of microscopic motions of atoms and atomic groups into the global collective motions of the protein.

  2. Search for the suppressed decays $B^{+}\\rightarrow K^{+}K^{+}\\pi^{-}$ and $B^{+}\\rightarrow \\pi^{+}\\pi^{+}K^{-}$

    CERN Document Server

    Aaij, Roel; Adinolfi, Marco; Ajaltouni, Ziad; Akar, Simon; Albrecht, Johannes; Alessio, Federico; Alexander, Michael; Ali, Suvayu; Alkhazov, Georgy; Alvarez Cartelle, Paula; Alves Jr, Antonio Augusto; Amato, Sandra; Amerio, Silvia; Amhis, Yasmine; An, Liupan; Anderlini, Lucio; Andreassi, Guido; Andreotti, Mirco; Andrews, Jason; Appleby, Robert; Aquines Gutierrez, Osvaldo; Archilli, Flavio; d'Argent, Philippe; Arnau Romeu, Joan; Artamonov, Alexander; Artuso, Marina; Aslanides, Elie; Auriemma, Giulio; Baalouch, Marouen; Babuschkin, Igor; Bachmann, Sebastian; Back, John; Badalov, Alexey; Baesso, Clarissa; Baldini, Wander; Barlow, Roger; Barschel, Colin; Barsuk, Sergey; Barter, William; Batozskaya, Varvara; Batsukh, Baasansuren; Battista, Vincenzo; Bay, Aurelio; Beaucourt, Leo; Beddow, John; Bedeschi, Franco; Bediaga, Ignacio; Bel, Lennaert; Bellee, Violaine; Belloli, Nicoletta; Belous, Konstantin; Belyaev, Ivan; Ben-Haim, Eli; Bencivenni, Giovanni; Benson, Sean; Benton, Jack; Berezhnoy, Alexander; Bernet, Roland; Bertolin, Alessandro; Betti, Federico; Bettler, Marc-Olivier; van Beuzekom, Martinus; Bezshyiko, Iaroslava; Bifani, Simone; Billoir, Pierre; Bird, Thomas; Birnkraut, Alex; Bitadze, Alexander; Bizzeti, Andrea; Blake, Thomas; Blanc, Frederic; Blouw, Johan; Blusk, Steven; Bocci, Valerio; Boettcher, Thomas; Bondar, Alexander; Bondar, Nikolay; Bonivento, Walter; Borgheresi, Alessio; Borghi, Silvia; Borisyak, Maxim; Borsato, Martino; Bossu, Francesco; Boubdir, Meriem; Bowcock, Themistocles; Bowen, Espen Eie; Bozzi, Concezio; Braun, Svende; Britsch, Markward; Britton, Thomas; Brodzicka, Jolanta; Buchanan, Emma; Burr, Christopher; Bursche, Albert; Buytaert, Jan; Cadeddu, Sandro; Calabrese, Roberto; Calvi, Marta; Calvo Gomez, Miriam; Camboni, Alessandro; Campana, Pierluigi; Campora Perez, Daniel; Campora Perez, Daniel Hugo; Capriotti, Lorenzo; Carbone, Angelo; Carboni, Giovanni; Cardinale, Roberta; Cardini, Alessandro; Carniti, Paolo; Carson, Laurence; Carvalho Akiba, Kazuyoshi; Casse, Gianluigi; Cassina, Lorenzo; Castillo Garcia, Lucia; Cattaneo, Marco; Cauet, Christophe; Cavallero, Giovanni; Cenci, Riccardo; Charles, Matthew; Charpentier, Philippe; Chatzikonstantinidis, Georgios; Chefdeville, Maximilien; Chen, Shanzhen; Cheung, Shu-Faye; Chobanova, Veronika; Chrzaszcz, Marcin; Cid Vidal, Xabier; Ciezarek, Gregory; Clarke, Peter; Clemencic, Marco; Cliff, Harry; Closier, Joel; Coco, Victor; Cogan, Julien; Cogneras, Eric; Cogoni, Violetta; Cojocariu, Lucian; Collazuol, Gianmaria; Collins, Paula; Comerma-Montells, Albert; Contu, Andrea; Cook, Andrew; Coquereau, Samuel; Corti, Gloria; Corvo, Marco; Costa Sobral, Cayo Mar; Couturier, Benjamin; Cowan, Greig; Craik, Daniel Charles; Crocombe, Andrew; Cruz Torres, Melissa Maria; Cunliffe, Samuel; Currie, Robert; D'Ambrosio, Carmelo; Dall'Occo, Elena; Dalseno, Jeremy; David, Pieter; Davis, Adam; De Aguiar Francisco, Oscar; De Bruyn, Kristof; De Capua, Stefano; De Cian, Michel; De Miranda, Jussara; De Paula, Leandro; De Serio, Marilisa; De Simone, Patrizia; Dean, Cameron Thomas; Decamp, Daniel; Deckenhoff, Mirko; Del Buono, Luigi; Demmer, Moritz; Derkach, Denis; Deschamps, Olivier; Dettori, Francesco; Dey, Biplab; Di Canto, Angelo; Dijkstra, Hans; Dordei, Francesca; Dorigo, Mirco; Dosil Su{á}rez, Alvaro; Dovbnya, Anatoliy; Dreimanis, Karlis; Dufour, Laurent; Dujany, Giulio; Dungs, Kevin; Durante, Paolo; Dzhelyadin, Rustem; Dziurda, Agnieszka; Dzyuba, Alexey; D{é}l{é}age, Nicolas; Easo, Sajan; Ebert, Marcus; Egede, Ulrik; Egorychev, Victor; Eidelman, Semen; Eisenhardt, Stephan; Eitschberger, Ulrich; Ekelhof, Robert; Eklund, Lars; Elsasser, Christian; Ely, Scott; Esen, Sevda; Evans, Hannah Mary; Evans, Timothy; Falabella, Antonio; Farley, Nathanael; Farry, Stephen; Fay, Robert; Fazzini, Davide; Ferguson, Dianne; Fernandez Albor, Victor; Fernandez Prieto, Antonio; Ferrari, Fabio; Ferreira Rodrigues, Fernando; Ferro-Luzzi, Massimiliano; Filippov, Sergey; Fini, Rosa Anna; Fiore, Marco; Fiorini, Massimiliano; Firlej, Miroslaw; Fitzpatrick, Conor; Fiutowski, Tomasz; Fleuret, Frederic; Fohl, Klaus; Fontana, Marianna; Fontanelli, Flavio; Forshaw, Dean Charles; Forty, Roger; Franco Lima, Vinicius; Frank, Markus; Frei, Christoph; Fu, Jinlin; Furfaro, Emiliano; F{ä}rber, Christian; Gallas Torreira, Abraham; Galli, Domenico; Gallorini, Stefano; Gambetta, Silvia; Gandelman, Miriam; Gandini, Paolo; Gao, Yuanning; Garcia Martin, Luis Miguel; Garc{í}a Pardi{ñ}as, Juli{á}n; Garra Tico, Jordi; Garrido, Lluis; Garsed, Philip John; Gascon, David; Gaspar, Clara; Gavardi, Laura; Gazzoni, Giulio; Gerick, David; Gersabeck, Evelina; Gersabeck, Marco; Gershon, Timothy; Ghez, Philippe; Gian{ì}, Sebastiana; Gibson, Valerie; Girard, Olivier G{ö}ran; Giubega, Lavinia-Helena; Gizdov, Konstantin; Gligorov, V.V.; Golubkov, Dmitry; Golutvin, Andrey; Gomes, Alvaro; Gorelov, Igor Vladimirovich; Gotti, Claudio; Grabalosa G{á}ndara, Marc; Graciani Diaz, Ricardo; Granado Cardoso, Luis Alberto; Graugés, Eugeni; Graverini, Elena; Graziani, Giacomo; Grecu, Alexandru; Griffith, Peter; Grillo, Lucia; Gruberg Cazon, Barak Raimond; Gr{ü}nberg, Oliver; Gushchin, Evgeny; Guz, Yury; Gys, Thierry; G{ö}bel, Carla; Hadavizadeh, Thomas; Hadjivasiliou, Christos; Haefeli, Guido; Haen, Christophe; Haines, Susan; Hall, Samuel; Hamilton, Brian; Han, Xiaoxue; Hansmann-Menzemer, Stephanie; Harnew, Neville; Harnew, Samuel; Harrison, Jonathan; Hatch, Mark; He, Jibo; Head, Timothy; Heister, Arno; Hennessy, Karol; Henrard, Pierre; Henry, Louis; Hernando Morata, Jose Angel; van Herwijnen, Eric; Heß, Miriam; Hicheur, Adl{è}ne; Hill, Donal; Hombach, Christoph; Hulsbergen, Wouter; Humair, Thibaud; Hushchyn, Mikhail; Hussain, Nazim; Hutchcroft, David; Idzik, Marek; Ilten, Philip; Jacobsson, Richard; Jaeger, Andreas; Jalocha, Pawel; Jans, Eddy; Jawahery, Abolhassan; John, Malcolm; Johnson, Daniel; Jones, Christopher; Joram, Christian; Jost, Beat; Jurik, Nathan; Kandybei, Sergii; Kanso, Walaa; Karacson, Matthias; Kariuki, James Mwangi; Karodia, Sarah; Kecke, Matthieu; Kelsey, Matthew; Kenyon, Ian; Kenzie, Matthew; Ketel, Tjeerd; Khairullin, Egor; Khanji, Basem; Khurewathanakul, Chitsanu; Kirn, Thomas; Klaver, Suzanne; Klimaszewski, Konrad; Koliiev, Serhii; Kolpin, Michael; Komarov, Ilya; Koopman, Rose; Koppenburg, Patrick; Kozachuk, Anastasiia; Kozeiha, Mohamad; Kravchuk, Leonid; Kreplin, Katharina; Kreps, Michal; Krokovny, Pavel; Kruse, Florian; Krzemien, Wojciech; Kucewicz, Wojciech; Kucharczyk, Marcin; Kudryavtsev, Vasily; Kuonen, Axel Kevin; Kurek, Krzysztof; Kvaratskheliya, Tengiz; Lacarrere, Daniel; Lafferty, George; Lai, Adriano; Lambert, Dean; Lanfranchi, Gaia; Langenbruch, Christoph; Langhans, Benedikt; Latham, Thomas; Lazzeroni, Cristina; Le Gac, Renaud; van Leerdam, Jeroen; Lees, Jean-Pierre; Leflat, Alexander; Lefran{ç}ois, Jacques; Lef{è}vre, Regis; Lemaitre, Florian; Lemos Cid, Edgar; Leroy, Olivier; Lesiak, Tadeusz; Leverington, Blake; Li, Yiming; Likhomanenko, Tatiana; Lindner, Rolf; Linn, Christian; Lionetto, Federica; Liu, Bo; Liu, Xuesong; Loh, David; Longstaff, Iain; Lopes, Jose; Lucchesi, Donatella; Lucio Martinez, Miriam; Luo, Haofei; Lupato, Anna; Luppi, Eleonora; Lupton, Oliver; Lusiani, Alberto; Lyu, Xiao-Rui; Machefert, Frederic; Maciuc, Florin; Maev, Oleg; Maguire, Kevin; Malde, Sneha; Malinin, Alexander; Maltsev, Timofei; Manca, Giulia; Mancinelli, Giampiero; Manning, Peter Michael; Maratas, Jan; Marchand, Jean Fran{ç}ois; Marconi, Umberto; Marin Benito, Carla; Marino, Pietro; Marks, J{ö}rg; Martellotti, Giuseppe; Martin, Morgan; Martinelli, Maurizio; Martinez Santos, Diego; Martinez Vidal, Fernando; Martins Tostes, Danielle; Massacrier, Laure Marie; Massafferri, Andr{é}; Matev, Rosen; Mathad, Abhijit; Mathe, Zoltan; Matteuzzi, Clara; Mauri, Andrea; Maurin, Brice; Mazurov, Alexander; McCann, Michael; McCarthy, James; McNab, Andrew; McNulty, Ronan; Meadows, Brian; Meier, Frank; Meissner, Marco; Melnychuk, Dmytro; Merk, Marcel; Merli, Andrea; Michielin, Emanuele; Milanes, Diego Alejandro; Minard, Marie-Noelle; Mitzel, Dominik Stefan; Mogini, Andrea; Molina Rodriguez, Josue; Monroy, Ignacio Alberto; Monteil, Stephane; Morandin, Mauro; Morawski, Piotr; Mord{à}, Alessandro; Morello, Michael Joseph; Moron, Jakub; Morris, Adam Benjamin; Mountain, Raymond; Muheim, Franz; Mulder, Mick; Mussini, Manuel; M{ü}ller, Dominik; M{ü}ller, Janine; M{ü}ller, Katharina; M{ü}ller, Vanessa; Naik, Paras; Nakada, Tatsuya; Nandakumar, Raja; Nandi, Anita; Nasteva, Irina; Needham, Matthew; Neri, Nicola; Neubert, Sebastian; Neufeld, Niko; Neuner, Max; Nguyen, Anh Duc; Nguyen-Mau, Chung; Nieswand, Simon; Niet, Ramon; Nikitin, Nikolay; Nikodem, Thomas; Novoselov, Alexey; O'Hanlon, Daniel Patrick; Oblakowska-Mucha, Agnieszka; Obraztsov, Vladimir; Ogilvy, Stephen; Oldeman, Rudolf; Onderwater, Gerco; Otalora Goicochea, Juan Martin; Otto, Adam; Owen, Patrick; Oyanguren, Maria Aranzazu; Pais, Preema Rennee; Palano, Antimo; Palombo, Fernando; Palutan, Matteo; Panman, Jacob; Papanestis, Antonios; Pappagallo, Marco; Pappalardo, Luciano; Pappenheimer, Cheryl; Parker, William; Parkes, Christopher; Passaleva, Giovanni; Pastore, Alessandra; Patel, Girish; Patel, Mitesh; Patrignani, Claudia; Pearce, Alex; Pellegrino, Antonio; Penso, Gianni; Pepe Altarelli, Monica; Perazzini, Stefano; Perret, Pascal; Pescatore, Luca; Petridis, Konstantinos; Petrolini, Alessandro; Petrov, Aleksandr; Petruzzo, Marco; Picatoste Olloqui, Eduardo; Pietrzyk, Boleslaw; Pikies, Malgorzata; Pinci, Davide; Pistone, Alessandro; Piucci, Alessio; Playfer, Stephen; Plo Casasus, Maximo; Poikela, Tuomas; Polci, Francesco; Poluektov, Anton; Polyakov, Ivan; Polycarpo, Erica; Pomery, Gabriela Johanna; Popov, Alexander; Popov, Dmitry; Popovici, Bogdan; Potterat, C{é}dric; Price, Eugenia; Price, Joseph David; Prisciandaro, Jessica; Pritchard, Adrian; Prouve, Claire; Pugatch, Valery; Puig Navarro, Albert; Punzi, Giovanni; Qian, Wenbin; Quagliani, Renato; Rachwal, Bartolomiej; Rademacker, Jonas; Rama, Matteo; Ramos Pernas, Miguel; Rangel, Murilo; Raniuk, Iurii; Raven, Gerhard; Redi, Federico; Reichert, Stefanie; dos Reis, Alberto; Remon Alepuz, Clara; Renaudin, Victor; Ricciardi, Stefania; Richards, Sophie; Rihl, Mariana; Rinnert, Kurt; Rives Molina, Vicente; Robbe, Patrick; Rodrigues, Ana Barbara; Rodrigues, Eduardo; Rodriguez Lopez, Jairo Alexis; Rodriguez Perez, Pablo; Rogozhnikov, Alexey; Roiser, Stefan; Romanovskiy, Vladimir; Romero Vidal, Antonio; Ronayne, John William; Rotondo, Marcello; Rudolph, Matthew Scott; Ruf, Thomas; Ruiz Valls, Pablo; Saborido Silva, Juan Jose; Sadykhov, Elnur; Sagidova, Naylya; Saitta, Biagio; Salustino Guimaraes, Valdir; Sanchez Mayordomo, Carlos; Sanmartin Sedes, Brais; Santacesaria, Roberta; Santamarina Rios, Cibran; Santimaria, Marco; Santovetti, Emanuele; Sarti, Alessio; Satriano, Celestina; Satta, Alessia; Saunders, Daniel Martin; Savrina, Darya; Schael, Stefan; Schellenberg, Margarete; Schiller, Manuel; Schindler, Heinrich; Schlupp, Maximilian; Schmelling, Michael; Schmelzer, Timon; Schmidt, Burkhard; Schneider, Olivier; Schopper, Andreas; Schubert, Konstantin; Schubiger, Maxime; Schune, Marie Helene; Schwemmer, Rainer; Sciascia, Barbara; Sciubba, Adalberto; Semennikov, Alexander; Sergi, Antonino; Serra, Nicola; Serrano, Justine; Sestini, Lorenzo; Seyfert, Paul; Shapkin, Mikhail; Shapoval, Illya; Shcheglov, Yury; Shears, Tara; Shekhtman, Lev; Shevchenko, Vladimir; Shires, Alexander; Siddi, Benedetto Gianluca; Silva Coutinho, Rafael; Silva de Oliveira, Luiz Gustavo; Simi, Gabriele; Simone, Saverio; Sirendi, Marek; Skidmore, Nicola; Skwarnicki, Tomasz; Smith, Eluned; Smith, Iwan Thomas; Smith, Jackson; Smith, Mark; Snoek, Hella; Sokoloff, Michael; Soler, Paul; Souza, Daniel; Souza De Paula, Bruno; Spaan, Bernhard; Spradlin, Patrick; Sridharan, Srikanth; Stagni, Federico; Stahl, Marian; Stahl, Sascha; Stefko, Pavol; Stefkova, Slavorima; Steinkamp, Olaf; Stemmle, Simon; Stenyakin, Oleg; Stevenson, Scott; Stoica, Sabin; Stone, Sheldon; Storaci, Barbara; Stracka, Simone; Straticiuc, Mihai; Straumann, Ulrich; Sun, Liang; Sutcliffe, William; Swientek, Krzysztof; Syropoulos, Vasileios; Szczekowski, Marek; Szumlak, Tomasz; T'Jampens, Stephane; Tayduganov, Andrey; Tekampe, Tobias; Tellarini, Giulia; Teubert, Frederic; Thomas, Christopher; Thomas, Eric; van Tilburg, Jeroen; Tisserand, Vincent; Tobin, Mark; Tolk, Siim; Tomassetti, Luca; Tonelli, Diego; Topp-Joergensen, Stig; Toriello, Francis; Tournefier, Edwige; Tourneur, Stephane; Trabelsi, Karim; Traill, Murdo; Tran, Minh T{â}m; Tresch, Marco; Trisovic, Ana; Tsaregorodtsev, Andrei; Tsopelas, Panagiotis; Tully, Alison; Tuning, Niels; Ukleja, Artur; Ustyuzhanin, Andrey; Uwer, Ulrich; Vacca, Claudia; Vagnoni, Vincenzo; Valat, Sebastien; Valenti, Giovanni; Vallier, Alexis; Vazquez Gomez, Ricardo; Vazquez Regueiro, Pablo; Vecchi, Stefania; van Veghel, Maarten; Velthuis, Jaap; Veltri, Michele; Veneziano, Giovanni; Venkateswaran, Aravindhan; Vernet, Maxime; Vesterinen, Mika; Viaud, Benoit; Vieira, Daniel; Vieites Diaz, Maria; Vilasis-Cardona, Xavier; Volkov, Vladimir; Vollhardt, Achim; Voneki, Balazs; Voong, David; Vorobyev, Alexey; Vorobyev, Vitaly; Voß, Christian; de Vries, Jacco; V{á}zquez Sierra, Carlos; Waldi, Roland; Wallace, Charlotte; Wallace, Ronan; Walsh, John; Wang, Jianchun; Ward, David; Wark, Heather Mckenzie; Watson, Nigel; Websdale, David; Weiden, Andreas; Whitehead, Mark; Wicht, Jean; Wilkinson, Guy; Wilkinson, Michael; Williams, Mark Richard James; Williams, Matthew; Williams, Mike; Williams, Timothy; Wilson, Fergus; Wimberley, Jack; Wishahi, Julian; Wislicki, Wojciech; Witek, Mariusz; Wormser, Guy; Wotton, Stephen; Wraight, Kenneth; Wright, Simon; Wyllie, Kenneth; Xie, Yuehong; Xing, Zhou; Xu, Zhirui; Yang, Zhenwei; Yin, Hang; Yu, Jiesheng; Yuan, Xuhao; Yushchenko, Oleg; Zangoli, Maria; Zarebski, Kristian Alexander; Zavertyaev, Mikhail; Zhang, Liming; Zhang, Yanxi; Zhang, Yu; Zhelezov, Alexey; Zheng, Yangheng; Zhokhov, Anatoly; Zhu, Xianglei; Zhukov, Valery; Zucchelli, Stefano

    2017-02-10

    A search is made for the highly-suppressed B meson decays $B^{+}\\rightarrow K^{+}K^{+}\\pi^{-}$ and $B^{+}\\rightarrow \\pi^{+}\\pi^{+}K^{-}$ using a data sample corresponding to an integrated luminosity of 3.0 $fb^{-1}$ collected by the LHCb experiment in proton-proton collisions at centre-of-mass energies of 7 and 8 TeV. No evidence is found for the decays, and upper limits at 90\\% confidence level are determined to be $\\mathcal{B}(B^{+}\\rightarrow K^{+}K^{+}\\pi^{-}) < 1.1\\times 10^{-8}$ and $\\mathcal{B}(B^{+}\\rightarrow \\pi^{+}\\pi^{+}K^{-}) < 4.6\\times 10^{-8}$.

  3. PI3KC2{alpha}, a class II PI3K, is required for dynamin-independent internalization pathways

    DEFF Research Database (Denmark)

    Krag, Claudia; Malmberg, Emily Kim; Salcini, Anna Elisabetta

    2010-01-01

    as fluid-phase endocytosis. Our data suggest a general role for PI3KC2a in regulating physiologically relevant dynamin-independent internalization pathways by recruiting early endosome antigen 1 (EEA1) to vesicular compartments, a step required for the intracellular trafficking of vesicles generated...... screen using a cell line expressing a diphtheria toxin receptor (DTR, officially known as HBEGF) anchored to GPI (DTR-GPI), which internalizes diphtheria toxin (DT, officially known as DTX) in a dynamin-independent manner, identified PI3KC2a, a class II phosphoinositide 3-kinase (PI3K), as a specific...... regulator of dynamin-independent DT internalization. We found that the internalization of several proteins that enter the cell through dynamin-independent pathways led to a relocalization of PI3KC2a to cargo-positive vesicles. Furthermore, downregulation of PI3KC2a impaired internalization of CD59 as well...

  4. 'Pop-Up' Governance: developing internal governance frameworks for consortia: the example of UK10K.

    Science.gov (United States)

    Kaye, Jane; Muddyman, Dawn; Smee, Carol; Kennedy, Karen; Bell, Jessica

    2015-01-01

    Innovations in information technologies have facilitated the development of new styles of research networks and forms of governance. This is evident in genomics where increasingly, research is carried out by large, interdisciplinary consortia focussing on a specific research endeavour. The UK10K project is an example of a human genomics consortium funded to provide insights into the genomics of rare conditions, and establish a community resource from generated sequence data. To achieve its objectives according to the agreed timetable, the UK10K project established an internal governance system to expedite the research and to deal with the complex issues that arose. The project's governance structure exemplifies a new form of network governance called 'pop-up' governance. 'Pop-up' because: it was put together quickly, existed for a specific period, was designed for a specific purpose, and was dismantled easily on project completion. In this paper, we use UK10K to describe how 'pop-up' governance works on the ground and how relational, hierarchical and contractual governance mechanisms are used in this new form of network governance.

  5. Laser cutting of thick steel plates and simulated steel components using a 30 kW fiber laser

    International Nuclear Information System (INIS)

    Tamura, Koji; Ishigami, Ryoya; Yamagishi, Ryuichiro

    2016-01-01

    Laser cutting of thick steel plates and simulated steel components using a 30 kW fiber laser was studied for application to nuclear decommissioning. Successful cutting of carbon steel and stainless steel plates up to 300 mm in thickness was demonstrated, as was that of thick steel components such as simulated reactor vessel walls, a large pipe, and a gate valve. The results indicate that laser cutting applied to nuclear decommissioning is a promising technology. (author)

  6. The performance of the K10, K6 and GHQ-12 to screen for present state DSM-IV disorders among disability claimants

    Directory of Open Access Journals (Sweden)

    Cornelius Bert LR

    2013-02-01

    Full Text Available Abstract Background Screening for mental disorders among disability claimants is important, since mental disorders seem to be seriously under-recognized in this population. However, performance of potentially suitable scales is unknown. We aimed to evaluate the psychometric properties of three scales, the 10- and 6-item Kessler Psychological Distress Scale (K10, K6 and the 12-item General Health Questionnaire (GHQ-12, to predict present state mental disorders, classified according to the Diagnostic and Statistical Manual of Mental Disorders, 4thEdition (DSM-IV among disability claimants. Methods All scales were completed by a representative sample of persons claiming disability benefit after two years sickness absence (n=293. All diagnoses, both somatic and mental, were included. The gold standard was the Composite International Diagnostic Interview (CIDI 3.0 to diagnose present state DSM-IV disorder. Cronbach’s α, sensitivity, specificity, positive (PPV and negative predictive values (NPV, and the areas under the Receiver Operating Characteristic curve (AUC were calculated. Results Cronbach’s alpha’s were 0.919 (K10, 0.882 (K6 and 0.906 (GHQ-12. The optimal cut-off scores were 24 (K10, 14 ( K6 and 20 (GHQ-12. The PPV and the NPV for the optimal cut point of the K10 was 0.53 and 0.89, for the K6 0.51 and 0.87, and for the GHQ-12 0.50 and 0.82. The AUC’s for 30-day cases were 0.806 (K10; 95% CI 0.749-0.862, 0.796 (K6; 95% CI 0.737-0.854 and 0.695 (GHQ-12; 95% CI 0.626-0.765. Conclusions The K10 and K6 are reliable and valid scales to screen for present state DSM-IV mental disorder. The optimal cut-off scores are 24 (K10 and 14 (K6. The GHQ-12 (optimal cut-off score: 20 is outperformed by the K10 and K6, which are to be preferred above the GHQ-12. The scores on separate items of the K10 and K6 can be used in disability assessment settings as an agenda for an in-depth follow-up clinical interview to ascertain the presence of present state

  7. Datasets collected in general practice: an international comparison using the example of obesity.

    Science.gov (United States)

    Sturgiss, Elizabeth; van Boven, Kees

    2018-06-04

    International datasets from general practice enable the comparison of how conditions are managed within consultations in different primary healthcare settings. The Australian Bettering the Evaluation and Care of Health (BEACH) and TransHIS from the Netherlands collect in-consultation general practice data that have been used extensively to inform local policy and practice. Obesity is a global health issue with different countries applying varying approaches to management. The objective of the present paper is to compare the primary care management of obesity in Australia and the Netherlands using data collected from consultations. Despite the different prevalence in obesity in the two countries, the number of patients per 1000 patient-years seen with obesity is similar. Patients in Australia with obesity are referred to allied health practitioners more often than Dutch patients. Without quality general practice data, primary care researchers will not have data about the management of conditions within consultations. We use obesity to highlight the strengths of these general practice data sources and to compare their differences. What is known about the topic? Australia had one of the longest-running consecutive datasets about general practice activity in the world, but it has recently lost government funding. The Netherlands has a longitudinal general practice dataset of information collected within consultations since 1985. What does this paper add? We discuss the benefits of general practice-collected data in two countries. Using obesity as a case example, we compare management in general practice between Australia and the Netherlands. This type of analysis should start all international collaborations of primary care management of any health condition. Having a national general practice dataset allows international comparisons of the management of conditions with primary care. Without a current, quality general practice dataset, primary care researchers will not

  8. Reference population for international comparisons and time trend surveillance of preterm delivery proportions in three countries

    DEFF Research Database (Denmark)

    Morken, N.H.; Vogel, I.; Kallen, K.

    2008-01-01

    BACKGROUND: International comparison and time trend surveillance of preterm delivery rates is complex. New techniques that could facilitate interpretation of such rates are needed. METHODS: We studied all live births and stillbirths (>or= 28 weeks gestation) registered in the medical birth...

  9. Low-temperature internal friction in high-purity monocrystalline and impure polycrystalline niobium after plastic deformation

    International Nuclear Information System (INIS)

    Wasserbaech, W.; Thompson, E.

    2001-01-01

    The internal friction Q -1 of plastically deformed, high-purity monocrystalline and impure polycrystalline niobium specimens was measured in the temperature range between 65 mK and about 2 K. Plastic deformation has a pronounced effect on the internal friction Q -1 of the high-purity monocrystalline specimens, and the effect has been found to be almost temperature independent. By contrast, surprisingly, the internal friction Q -1 of the impure polycrystalline specimens was found to be almost independent of the extent of plastic deformation. Comparison of the experimental results with different models of a dynamic scattering of acoustic phonons by dislocations leads to the conclusion that the results cannot be explained with the two-level tunneling model. Instead it is suggested that a strong interaction between acoustic phonons and geometrical kinks in non-screw dislocations is responsible for the observed internal friction Q -1 . (orig.)

  10. International comparisons of behavioral and emotional problems in preschool children: parents' reports from 24 societies

    DEFF Research Database (Denmark)

    Rescorla, Leslie A; Achenbach, Thomas M; Ivanova, Masha Y

    2011-01-01

    International comparisons were conducted of preschool children's behavioral and emotional problems as reported on the Child Behavior Checklist for Ages 1½-5 by parents in 24 societies (N = 19,850). Item ratings were aggregated into scores on syndromes; Diagnostic and Statistical Manual of Mental...... Disorders-oriented scales; a Stress Problems scale; and Internalizing, Externalizing, and Total Problems scales. Effect sizes for scale score differences among the 24 societies ranged from small to medium (3-12%). Although societies differed greatly in language, culture, and other characteristics, Total...

  11. Comparison of microscopic and endoscopic view of the internal acoustic meatus: A cadaveric study.

    Science.gov (United States)

    Montibeller, Guilherme Ramina; Hendrix, Philipp; Fries, Fabian N; Becker, Kurt W; Oertel, Joachim

    2018-04-01

    The endoscope is thought to provide an improved exposure of the internal acoustic meatus after retrosigmoid craniotomy for microsurgical resection of intrameatal tumors. The aim of this study is to quantify the differences in internal acoustic meatus (IAM) exposure comparing microscopic and endoscopic visualization. A retrosigmoid approach was performed on 5 cadaver heads. A millimeter gauge was introduced into the internal acoustic meatus, and examinations with a surgical microscope and 0°, 30° and 70° rigid endoscopes were performed. The extent of IAM depth visualized with the microscope and the different angled endoscopes were analyzed. The microscopic view allowed an average IAM depth visualization of 2.8 mm. The endoscope allowed an improved exposure of IAM in all cases. The 0°, 30° and 70° endoscopes permitted an exposure that was respectively 96% (5.5 mm), 139% (6.7 mm) and 200% (8.4 mm) more lateral than the microscopic view. Angled optics, however, provided an image distortion, specifically the 70° endoscope. The endoscope provides a superior visualization of the IAM compared to the microscope when using a retrosigmoid approach. The 30° endoscope represented an ideal compromise of superior visualization with marginal image distortion. Additional implementation of the endoscope into microsurgery of intrameatal tumors likely facilitates complete tumor removal and might spare facial and vestibulocochlear function. Clin. Anat. 31:398-403, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  12. International Comparisons of Behavioral and Emotional Problems in Preschool Children: Parents' Reports from 24 Societies

    Science.gov (United States)

    Rescorla, Leslie A.; Achenbach, Thomas M.; Ivanova, Masha Y.; Harder, Valerie S.; Otten, Laura; Bilenberg, Niels; Bjarnadottir, Gudrun; Capron, Christiane; De Pauw, Sarah S. W.; Dias, Pedro; Dobrean, Anca; Dopfner, Manfred; Duyme, Michel; Eapen, Valsamma; Erol, Nese; Esmaeili, Elaheh Mohammad; Ezpeleta, Lourdes; Frigerio, Alessandra; Fung, Daniel S. S.; Goncalves, Miguel; Gudmundsson, Halldor; Jeng, Suh-Fang; Jusiene, Roma; Kim, Young Ah; Kristensen, Solvejg; Liu, Jianghong; Lecannelier, Felipe; Leung, Patrick W. L.; Machado, Barbara Cesar; Montirosso, Rosario; Oh, Kyung Ja; Ooi, Yoon Phaik; Pluck, Julia; Pomalima, Rolando; Pranvera, Jetishi; Schmeck, Klaus; Shahini, Mimoza; Silva, Jaime R.; Simsek, Zeynep; Sourander, Andre; Valverde, Jose; van der Ende, Jan; Van Leeuwen, Karla G.; Wu, Yen-Tzu; Yurdusen, Sema; Zubrick, Stephen R.; Verhulst, Frank C.

    2011-01-01

    International comparisons were conducted of preschool children's behavioral and emotional problems as reported on the Child Behavior Checklist for Ages 1 1/2-5 by parents in 24 societies (N = 19,850). Item ratings were aggregated into scores on syndromes; "Diagnostic and Statistical Manual of Mental Disorders"-oriented scales; a Stress…

  13. Measurement comparisons of radioactivity among European monitoring laboratories for the environment and food stuff

    International Nuclear Information System (INIS)

    Waetjen, U.; Spasova, Y.; Altzitzoglou, T.

    2008-01-01

    For more than 15 years, European Union (EU) laboratories monitoring environmental radioactivity have been obliged to participate in measurement comparisons organised by the European Commission. After a short review of comparisons conducted during the 1990s, the approach of IRMM organising these comparisons since 2003 is presented. It relies on the provision of comparison samples with reference values traceable to the International Reference System for radionuclides (SIR). The results of the most recent comparison, the determination of 40 K, 90 Sr and 137 Cs in milk powder, are presented. The influence of repetitive participation in measurement comparisons on laboratory performance is studied on the basis of data from more than 20 laboratories having participated in several exercises during the last 15 years

  14. Dimerization of nitrophorin 4 at low pH and comparison to the K1A mutant of nitrophorin 1.

    Science.gov (United States)

    Berry, Robert E; Yang, Fei; Shokhireva, Tatiana K; Amoia, Angela M; Garrett, Sarah A; Goren, Allena M; Korte, Stephanie R; Zhang, Hongjun; Weichsel, Andrzej; Montfort, William R; Walker, F Ann

    2015-01-20

    Nitrophorin 4, one of the four NO-carrying heme proteins from the salivary glands of Rhodnius prolixus, forms a homodimer at pH 5.0 with a Kd of ∼8 μM. This dimer begins to dissociate at pH 5.5 and is completely dissociated to monomer at pH 7.3, even at 3.7 mM. The dimer is significantly stabilized by binding NO to the heme and at pH 7.3 would require dilution to well below 0.2 mM to completely dissociate the NP4-NO homodimer. The primary techniques used for investigating the homodimer and the monomer-dimer equilibrium were size-exclusion fast protein liquid chromatography at pH 5.0 and (1)H{(15)N} heteronuclear single-quantum coherence spectroscopy as a function of pH and concentration. Preparation of site-directed mutants of NP4 (A1K, D30A, D30N, V36A/D129A/L130A, K38A, R39A, K125A, K125E, D132A, L133V, and K38Q/R39Q/K125Q) showed that the N-terminus, D30, D129, D132, at least one heme propionate, and, by association, likely also E32 and D35 are involved in the dimerization. The "closed loop" form of the A-B and G-H flexible loops of monomeric NP4, which predominates in crystal structures of the monomeric protein reported at pH 5.6 but not at pH 7.5 and which involves all of the residues listed above except D132, is required for dimer formation. Wild-type NP1 does not form a homodimer, but NP1(K1A) and native N-terminal NP1 form dimers in the presence of NO. The homodimer of NP1, however, is considerably less stable than that of NP4 in the absence of NO. This suggests that additional aspartate or glutamate residues present in the C-terminal region of NP4, but not NP1, are also involved in stabilizing the dimer.

  15. Internal emitter research and standard setting

    International Nuclear Information System (INIS)

    Stannard, J.N.

    1981-01-01

    The history of the use of data from internal emitter research in the derivation of safety standards is reviewed. At first, observed biological effects were correlated with body burdens or exposure levels. This direct approach is illustrated by detailed accounts of the cases of uranium and plutonium. In the 1950's, when it was decided to provide standards for over 200 isotopes, the direct approach was replaced by a system of calculations. This necessitated changes in internal emitter research programs to provide metabolic data, and the development of models such as Reference Man and the Lung and Gastrointestinal Tract models. The continuing contribution of internal emitter research to standard setting can be seen in the references quoted in the metabolic data section of the new ICRP report (ICRP Publication 30). Present trends suggest a possible return to the direct use of internal emitter effects data for obtaining risk estimates. (U.K.)

  16. Women with Childhood ADHD: Comparisons by Diagnostic Group and Gender

    OpenAIRE

    Babinski, Dara E.; Pelham, William E.; Molina, Brooke S. G.; Waschbusch, Daniel A.; Gnagy, Elizabeth M.; Yu, Jihnhee; Sibley, Margaret H.; Biswas, Aparajita

    2011-01-01

    This study compared adult women with childhood ADHD to adult women without childhood ADHD and to adult men with childhood ADHD. The participants, all from a larger longitudinal study, included 30 women and 30 men (approximately age 23 to 24) with childhood ADHD, and 27 women without ADHD. Women with childhood ADHD were matched to comparison women on age, ethnicity, and parental education, and to men with childhood ADHD on age, ethnicity, and IQ. Self- and parent-reports of internalizing, inte...

  17. APMP.QM-S8: determination of mass fraction of benzoic acid, methyl paraben and n-butyl paraben in soy sauce

    Science.gov (United States)

    Teo, Tang Lin; Gui, Ee Mei; Lu, Ting; Sze Cheow, Pui; Giannikopoulou, Panagiota; Kakoulides, Elias; Lampi, Evgenia; Choi, Sik-man; Yip, Yiu-chung; Chan, Pui-kwan; Hui, Sin-kam; Wollinger, Wagner; Carvalho, Lucas J.; Garrido, Bruno C.; Rego, Eliane C. P.; Ahn, Seonghee; Kim, Byungjoo; Li, Xiuqin; Guo, Zhen; Styarini, Dyah; Aristiawan, Yosi; Putri Ramadhaningtyas, Dillani; Aryana, Nurhani; Ebarvia, Benilda S.; Dacuaya, Aaron; Tongson, Alleni; Aganda, Kim Christopher; Junvee Fortune, Thippaya; Tangtrirat, Pradthana; Mungmeechai, Thanarak; Ceyhan Gören, Ahmet; Gündüz, Simay; Yilmaz, Hasibe

    2017-01-01

    /kg with a combined standard uncertainty of 1.36 mg/kg. The k-factors for the estimation of the expanded uncertainties of the SCRVs were 2.26, 2.57 and 2.57, respectively. The degree of equivalence (with the SCRV) and its uncertainty were calculated for each result. All the participating institutes (except in one case for benzoic acid) were able to demonstrate or confirm their capabilities in the determination of polar food preservatives in water or aqueous-based beverages/condiments. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. International key comparison of free-field hydrophone calibrations in the frequency range 1 to 500 kHz

    CSIR Research Space (South Africa)

    Robinson, SP

    2006-09-01

    Full Text Available South African Develop- ment Community Cooperation in Measurement TraceabilityH20850, and SIM H20849Sistema Interamericano de MetrologiaH20850. Also listed in Table I are the country codes used to identify the results in the graphical representations... in the database on the BIPM web- site also include tabulated data on the bilateral degrees of equivalence between the countries along with associated uncertainties. The data generated by the comparison are available on the BIPM website at H20855http...

  19. FOREWORD: CCM Second International Seminar: Pressure Metrology from 1 kPa to 1 GPa

    Science.gov (United States)

    Molinar, G. F.

    1994-01-01

    The Comité Consultatif pour la Masse et les Grandeurs Apparentées (CCM), through its High Pressure and Medium Pressure Working Groups, organized this Second International Seminar on Pressure Metrology from 1 kPa to 1 GPa, which was held at the Laboratoire National d'Essais (LNE), Paris, France, from 2 to 4 June 1993. The scope of the seminar was to review the state of the art of pressure measurements in the 1 kPa to I GPa pressure range and to present innovative contributions by standards laboratories, universities and industry. The seminar was organized in six sessions: liquid-column manometers; piston gauge pressure standards; properties of liquids and gases relevant to pressure metrology; pressure transducers and transfer standards; pressure standard comparison (methods and results); dynamic pressure measurements. Each session opened with the presentation of a review paper on major requirements in that field and, at the end of the seminar, a general discussion was organized on the actual limits of accuracy of static and dynamic pressure measurements in fluid media, and the fundamental problems in pressure metrology between 1 kPa and 1 GPa. The seminar was attended by sixty scientists from twenty-four countries, all working in the field of pressure measurements. Forty-nine papers were presented. The participation of scientists from so many countries indicates the importance of pressure metrology from the scientific and industrial points of view. Most papers were presented by scientists from national standards laboratories, with eight papers from universities and four from industry. Eleven papers reported the results of cooperative work involving metrological institutions dealing with high pressure, generally national standards laboratories, an indication that scientific links are already well established at this level. Links are also strengthening between industry and standards laboratories. Although industrial participation at the seminar was relatively small

  20. Y2K and International Agricultural Transportation: Analysis of Export Markets, Import Suppliers, and Major Food Aid Recipient Countries

    Science.gov (United States)

    1999-09-01

    USDA Y2K information assessment of international food transportation modes in : selected foreign countries. The assessment targeted 9 of the top 10 markets for : U.S. Agricultural exports and 7 of the top 8 suppliers of imported food products : to th...

  1. Comparison of molecular methods for visceral leishmaniasis diagnosis in asymptomatic dogs

    Energy Technology Data Exchange (ETDEWEB)

    Carregal, Virginia M.; Leite, Rodrigo S.; Andrade, Antero S.R., E-mail: antero@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Lab. de Radiobiologia; Melo, Maria N., E-mail: melo@icb.ufmg.br [Universidade Federal de Minas Gerais (ICB/UFMG), Belo Horizonte, MG (Brazil). Inst. de Ciencias Biologicas. Dept. de Parasitologia

    2011-07-01

    Visceral Leishmaniasis (VL) is a serious public health problem in Brazil. In the urban area dog is the main source of infection and VL control in Brazil involves the elimination of infected dogs. Serological tests are used for routine surveys, but they present problems of specificity and sensitivity. In addition, serologic test performance depends on infection status and an important limitation in VL control programs is the inability to identify asymptomatic dogs because these tests are insufficiently sensitive. Molecular methods as the kPCR PCR - hybridization are useful in the diagnosis and identification of Leishmania species. The kDNA PCR - hybridization uses radioactive probes to improve the sensibility of the PCR and allow the discrimination between Leishmania species. The aim of this work was compare the sensibility of the method kDNA PCR - Hybridization with different PCR methods, in different clinical samples, for VL diagnosis in asymptomatic animals. Bone marrow, peripheral blood, conjunctival swab and skin biopsies had been analyzed by the methods kDNA PCR - hybridization, kDNA semi nested PCR (kDNA snPCR), Leishmania nested PCR (LnPCR) e Internal Transcribed Spacer 1 nested PCR (ITS-1 nPCR). Thirty positive asymptomatic dogs with positive serologic and parasitologic tests were used. Six not infected dogs had been used as controls. The DNA extraction from swabs was performed by Phenol-Chloroform method. Commercial kits had been used for DNA extraction of peripheral blood, bone marrow and skin biopsies. The kDNA PCR - hybridization detected 5/30 (16.7 %) positive dogs for peripheral blood, 17/30 (57%) for skin, 19/30 (63.3 %) for bone marrow and 21/30 (70%) for conjunctival swab. The kDNA snPCR found 7/30 (23.3%) positive dogs for peripheral blood, 17/30 (57%) for skin, 12/30 (40%) for bone marrow and 24/30 (80%) samples of conjunctival swab. The LnPCR method detected 9/30 (30%) positive dogs for the samples of peripheral blood, 15/30 (50%) for bone

  2. Comparison of molecular methods for visceral leishmaniasis diagnosis in asymptomatic dogs

    International Nuclear Information System (INIS)

    Carregal, Virginia M.; Leite, Rodrigo S.; Andrade, Antero S.R.; Melo, Maria N.

    2011-01-01

    Visceral Leishmaniasis (VL) is a serious public health problem in Brazil. In the urban area dog is the main source of infection and VL control in Brazil involves the elimination of infected dogs. Serological tests are used for routine surveys, but they present problems of specificity and sensitivity. In addition, serologic test performance depends on infection status and an important limitation in VL control programs is the inability to identify asymptomatic dogs because these tests are insufficiently sensitive. Molecular methods as the kPCR PCR - hybridization are useful in the diagnosis and identification of Leishmania species. The kDNA PCR - hybridization uses radioactive probes to improve the sensibility of the PCR and allow the discrimination between Leishmania species. The aim of this work was compare the sensibility of the method kDNA PCR - Hybridization with different PCR methods, in different clinical samples, for VL diagnosis in asymptomatic animals. Bone marrow, peripheral blood, conjunctival swab and skin biopsies had been analyzed by the methods kDNA PCR - hybridization, kDNA semi nested PCR (kDNA snPCR), Leishmania nested PCR (LnPCR) e Internal Transcribed Spacer 1 nested PCR (ITS-1 nPCR). Thirty positive asymptomatic dogs with positive serologic and parasitologic tests were used. Six not infected dogs had been used as controls. The DNA extraction from swabs was performed by Phenol-Chloroform method. Commercial kits had been used for DNA extraction of peripheral blood, bone marrow and skin biopsies. The kDNA PCR - hybridization detected 5/30 (16.7 %) positive dogs for peripheral blood, 17/30 (57%) for skin, 19/30 (63.3 %) for bone marrow and 21/30 (70%) for conjunctival swab. The kDNA snPCR found 7/30 (23.3%) positive dogs for peripheral blood, 17/30 (57%) for skin, 12/30 (40%) for bone marrow and 24/30 (80%) samples of conjunctival swab. The LnPCR method detected 9/30 (30%) positive dogs for the samples of peripheral blood, 15/30 (50%) for bone

  3. Methods for estimation of internal dose of the public from dietary

    International Nuclear Information System (INIS)

    Zhu Hongda

    1987-01-01

    Following the issue of its Publication 26, ICRP has successively published its Publication 30 to meet the great changes and improvements made in the Basic Recommendations since July of 1979. In Part 1 of Publcation 30, ICRP recommended a new method for internal dose estimation and pressented some important data. In this report, comparison is made among methods for estimation of internal dose for the public from dietary. They include: (1) the new method suggested by ICRP; (2) the simple and convenient method using transfer factors under equilibrium conditions; (3) the methods based on the similarities of several radionuclides to their chemical analogs. It is concluded that the first method is better than the others and should be used from now on

  4. Activity measurements of the radionuclide {sup 124}Sb by the LNE-LNHB, France for the ongoing comparison BIPM.RI(II)-K1.Sb-124

    Energy Technology Data Exchange (ETDEWEB)

    Michotte, C.; Ratel, G. [Bureau International des Poids et Mesures (BIPM), Pavillon de Breteuil, F-92312 Sevres Cedex, (France); Moune, M.; Bobin, C. [Laboratoire national de metrologie et d' essais-Laboratoire national Henri Becquerel, 91191 Gif-sur-Yvette cedex, (France)

    2011-07-01

    In 2007, the Laboratoire national de metrologie et d'essais-Laboratoire national Henri Becquerel (LNE-LNHB), France submitted a sample of known activity of {sup 124}Sb to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). The activity was about 5.3 MBq. The key comparison reference value (KCRV) has been recalculated to include this new value and the degrees of equivalence between each equivalent activity for the three participants measured in the SIR and the KCRV are presented in a table and graphically. (authors)

  5. Age-related differences in internalizing psychopathology amongst the Australian general population.

    Science.gov (United States)

    Sunderland, Matthew; Slade, Tim; Carragher, Natacha; Batterham, Philip; Buchan, Heather

    2013-11-01

    Two methodological criticisms have limited the reliability and validity of findings from previous studies that seek to examine change across the life span in levels of internalizing psychopathology using general population surveys. The first criticism involves the potential influence of cohort effects that confound true age-related changes whereas the second criticism involves the use of a single form of assessment to measure and compare levels of internalizing psychopathology. This study seeks to address these criticisms by modeling age-related change using multiple measures and multiple surveys. Data from 2 epidemiological surveys conducted 10 years apart in the Australian general population were combined and used for the current study. The latent construct of internalizing psychopathology was modeled using a combination of Diagnostic and Statistical Manual of Mental Disorders (4th ed.; DSM-IV; American Psychiatric Association, 1994) depression and anxiety diagnoses as well as items from the Kessler Psychological Distress scale (K10; Kessler et al., 2002). Confirmatory factor analysis (CFA) indicated that a single internalizing dimension provided good model fit to the data. Multigroup CFA indicated that strict measurement invariance of the model can be assumed across survey administrations and age bands, justifying comparisons of mean differences in latent trait levels. Significant changes in mean levels of latent internalizing psychopathology were evident between respondents aged 30-39 years old in 1997 and respondents aged 40-49 years old in 2007, suggesting a minor but significant increase in psychopathology across middle age. By contrast, a minor but significant decrease in psychopathology was noted when transitioning from late middle age (50-59 years old) to old age (60-69 years old). The majority of individuals in the general population will experience constant levels of internalizing psychopathology as they age, suggesting that the construct is relatively

  6. Austrian emission under international comparison

    International Nuclear Information System (INIS)

    Anderl, M.; Gager, M.; Gugele, B.; Huttunen, K.; Kurzweil, A.; Poupa, S.; Ritter, M.; Wappel, D.; Wieser, M.

    2004-01-01

    A comparison between anthropogenic emissions of CO 2 , CH 4 , N 2 O, SO 2 , NO x , volatile organic compounds (NMVOC), NH 3 and CO from the European Union, European Union candidate countries and Austria is presented. Data covers the years 1999-2001 and the emissions values per habitant are provided as well as a comparison against the Kyoto goals. In the middle of the European mean values are the austrian emissions values, austrian SO 2 emissions are the smallest, however CH 4 , CO and NMVOC emissions are over the European mean values. 8 figs., 6 tabs. (nevyjel)

  7. Towards valid 'serious non-fatal injury' indicators for international comparisons based on probability of admission estimates

    DEFF Research Database (Denmark)

    Cryer, Colin; Miller, Ted R; Lyons, Ronan A

    2017-01-01

    in regions of Canada, Denmark, Greece, Spain and the USA. International Classification of Diseases (ICD)-9 or ICD-10 4-digit/character injury diagnosis-specific ED attendance and inpatient admission counts were provided, based on a common protocol. Diagnosis-specific and region-specific PrAs with 95% CIs...... diagnoses with high estimated PrAs. These diagnoses can be used as the basis for more valid international comparisons of life-threatening injury, based on hospital discharge data, for countries with well-developed healthcare and data collection systems....

  8. Comparison of two new angiogenesis PET tracers 68Ga-NODAGA-E[c(RGDyK)]2 and 64Cu-NODAGA-E[c(RGDyK)]2; in vivo imaging studies in human xenograft tumors

    DEFF Research Database (Denmark)

    Oxbøl, Jytte; Brandt-Larsen, Malene; Schjøth-Eskesen, Christina

    2014-01-01

    INTRODUCTION: The aim of this study was to synthesize and perform a side-by-side comparison of two new tumor-angiogenesis PET tracers (68)Ga-NODAGA-E[c(RGDyK)](2) and (64)Cu-NODAGA-E[c(RGDyK)](2) in vivo using human xenograft tumors in mice. Human radiation burden was estimated to evaluate...... potential for future use as clinical PET tracers for imaging of neo-angiogenesis. METHODS: A (68)Ge/(68)Ga generator was used for the synthesis of (68)Ga-NODAGA-E[c(RGDyK)](2). (68)Ga and (64)Cu labeled NODAGA-E[c(RGDyK)](2) tracers were administrated in nude mice bearing either human glioblastoma (U87MG......) or human neuroendocrine (H727) xenograft tumors. PET/CT scans at 3 time points were used for calculating the tracer uptake in tumors (%ID/g), integrin αVβ3 target specificity was shown by blocking with cold NODAGA-E[c(RGDyK)](2), and biodistribution in normal organs were also examined. From biodistribution...

  9. Protein resonance assignment at MAS frequencies approaching 100 kHz: a quantitative comparison of J-coupling and dipolar-coupling-based transfer methods

    Energy Technology Data Exchange (ETDEWEB)

    Penzel, Susanne; Smith, Albert A.; Agarwal, Vipin; Hunkeler, Andreas [ETH Zürich, Physical Chemistry (Switzerland); Org, Mai-Liis; Samoson, Ago, E-mail: ago.samoson@ttu.ee [Tallinn University of Technology, NMR Instituut, Tartu Teadus, Tehnomeedikum (Estonia); Böckmann, Anja, E-mail: a.bockmann@ibcp.fr [UMR 5086 CNRS/Université de Lyon 1, Institut de Biologie et Chimie des Protéines (France); Ernst, Matthias, E-mail: maer@ethz.ch; Meier, Beat H., E-mail: beme@ethz.ch [ETH Zürich, Physical Chemistry (Switzerland)

    2015-10-15

    We discuss the optimum experimental conditions to obtain assignment spectra for solid proteins at magic-angle spinning (MAS) frequencies around 100 kHz. We present a systematic examination of the MAS dependence of the amide proton T{sub 2}′ times and a site-specific comparison of T{sub 2}′ at 93 kHz versus 60 kHz MAS frequency. A quantitative analysis of transfer efficiencies of building blocks, as they are used for typical 3D experiments, was performed. To do this, we compared dipolar-coupling and J-coupling based transfer steps. The building blocks were then combined into 3D experiments for sequential resonance assignment, where we evaluated signal-to-noise ratio and information content of the different 3D spectra in order to identify the best assignment strategy. Based on this comparison, six experiments were selected to optimally assign the model protein ubiquitin, solely using spectra acquired at 93 kHz MAS. Within 3 days of instrument time, the required spectra were recorded from which the backbone resonances have been assigned to over 96 %.

  10. Partial molar volumes of organic solutes in water. XXIII. Cyclic ketones at T = (298 to 573) K and pressures up to 30 MPa

    International Nuclear Information System (INIS)

    Cibulka, Ivan; Simurka, Lukas; Hnedkovsky, Lubomir; Bolotov, Alexander

    2011-01-01

    Research highlights: → In this study we examine standard molar volumes of aqueous cyclic ketones. → State parameters of measurements were (298 to 573) K and pressures up to 30 MPa. → Differences in behavior of monoketones and cyclohexane-1,4-dione were observed. → Group contribution method was designed and examined. - Abstract: Density data for dilute aqueous solutions of four cyclic ketones (cyclopentanone, cyclohexanone, cycloheptanone, and cyclohexane-1,4-dione) are presented together with standard molar volumes (partial molar volumes at infinite dilution) calculated from the experimental data. The measurements were performed at temperatures from T = 298 K up to T = 573 K. Experimental pressures were close to the saturated vapor pressure of water, and (15 and 30) MPa. The data were obtained using a high-temperature high-pressure flow vibrating-tube densimeter. Experimental standard molar volumes were correlated as a function of temperature and pressure using an empirical polynomial function. Contributions of the molecular structural segments (methylene and carbonyl groups) to the standard molar volume were also evaluated and analyzed.

  11. A comparison of international criteria for the ultimate storage of radioactive wastes

    International Nuclear Information System (INIS)

    Mielke, H.

    1985-01-01

    In countries other than the Federal Republic of Germany and internationally there are no comprehensive codes referring to criteria and safety requirements except those of the IAEA and USA. In other countries there exist safety goals for the ultimate storage or for purely geological criteria. The degree of detailing regulations differs widely abroad and internationally. Safety goals abroad and internationally as well as measures for their realisation in the ultimate storage of radioactive wastes in deep geological formations are in line with the German safety goals. The IAEA refers to general aspects of geological, waste technology and ultimate storage technology criteria. In the USA, ultimate storage technology criteria have been quantified in part. The quantitative geological criteria existing in Great Britain and in the Netherlands are only relevant in as much as safety analyses must be performed for a specific site to provide evidence for the safety of this site. The comparison shows that most requirements pronounced abroad are also made for the Federal Republic of Germany. Some requirements are more specified in the Federal Republic of Germany, some are more detailed abroad. (orig./HP) [de

  12. Thin-Ideal Internalization and Comparison Process as Mediators of Social Influence and Psychological Functioning in the Development of Disturbed Eating Habits in Croatian College Females

    Directory of Open Access Journals (Sweden)

    Alessandra Pokrajac-Bulian

    2008-12-01

    Full Text Available This study examined the role of internalization and comparison as mediators of relationships between socio-cultural pressures to be thin, psychological factors, restrictive and bulimic behaviours in college females. Participants were 262 Croatian college females (mean age = 21.22 ± 1.47 years who completed self-report questionnaires. Regression analysis was used to test a model in which internalization and social comparison mediated the impact of socio-cultural pressure (parents and peers dieting, teasing, pressure to be thin, media influences, self-esteem, anxiety, depression, and perfectionism in restrictive and bulimic behaviours. Internalization is a significant mediator of the relationships between all predictors included in this research and disturbed eating habits. Social comparison is relevant as a mediator between social influence, negative affect, self-esteem, perfectionism and restrictive behaviour but does not mediate bulimic behaviour. These findings could be seful in understanding processes that may predispose young women to develop eating dysfunctions and indicate the need for prevention programs that incorporate formative influences and processes such as internalization of societal norms and comparison in the construction of therapeutic strategies.

  13. Comparison of different chemical kinetic mechanisms of methane combustion in an internal combustion engine configuration

    OpenAIRE

    Ennetta Ridha; Hamdi Mohamed; Said Rachid

    2008-01-01

    Three chemical kinetic mechanisms of methane combustion were tested and compared using the internal combustion engine model of Chemkin 4.02 [1]: one-step global reaction mechanism, four-step mechanism, and the standard detailed scheme GRIMECH 3.0. This study shows good concordances, especially between the four-step and the detailed mechanisms in the prediction of temperature and main species profiles. But reduced schemes were incapables to predict pollutant emissions in an internal combustion...

  14. Design of a 2 kA, 30 fs Rf-Photoinjector for Waterbag Compression

    Science.gov (United States)

    van der Geer, S. B.; Luiten, O. J.; de Loos, M. J.

    Because uniformly filled ellipsoidal ‘waterbag’ bunches have linear self-fields in all dimensions, they do not suffer from space-charge induced brightness degradation. This in turn allows very efficient longitudinal compression of high-brightness bunches at sub or mildly relativistic energies, a parameter regime inaccessible up to now due to detrimental effects of non-linear space-charge forces. To demonstrate the feasibility of this approach, we investigate ballistic bunching of 1 MeV, 100 pC waterbag electron bunches, created in a half-cell rf-photogun, by means of a two-cell booster-compressor. Detailed GPT simulations of this table-top set-up are presented, including realistic fields, 3D space-charge effects, path-length differences and image charges at the cathode. It is shown that with a single 10MW S-band klystron and fields of 100 MV/m, 2kA peak current is attainable with a pulse duration of only 30 fs at a transverse normalized emittance of 1.5 μm.

  15. The availability of German nuclear power plants in an international comparison

    International Nuclear Information System (INIS)

    Fehndrich, W.; Kutsch, W.

    1976-01-01

    Due to unprecise definitions, incomplete reports and the small number of plants in operation, an analysis of the availability of nuclear power stations by international standards meets some difficulties. Especially in the classification of causes of accidents, isolated cases gain too much importance due to the statistically small number of unscheduled shutdowns and thus often distort the picture. Still, the present comparison based on statements made by the ABE committee and the IAEA presents a good picture of availability tendencies and main types of failures and gives rise to the assumption that the initial difficulties with which every new technology has to cope will soon be overcome. (orig./AK) [de

  16. Investigation of states in 30P via the 30Si(3He,t)30P reaction at 30 MeV

    International Nuclear Information System (INIS)

    Ramstein, B.; Rosier, L.H.; Paris-11 Univ., 91 - Orsay; Meijer, R.J. de

    1981-01-01

    The 30 Si( 3 He,t) 30 P reaction has been measured for about 100 levels in 30 P with Esub(x)<8.8 MeV. Little selectivity in the population of states has been observed. For 75 levels angular distributions have been analysed using a 'fingerprint method' by determining the L-value from a comparison in shape with transition to states with known Jsup(π). For possible mixed L-transitions a dominance of the higher L-value is observed for almost all cases. Coulomb displacement energy calculations utilizing shell-model wave functions have been used to identify T=1 states

  17. [The quality of the German health-care system in an international comparison - a systematic review].

    Science.gov (United States)

    Lauerer, M; Emmert, M; Schöffski, O

    2013-08-01

    Studies assessing the quality of the German health-care system in an international comparison come to different results. Therefore, this review aims to investigate how the German health-care system is evaluated in comparison to other health-care systems by reviewing international publications. Results show starting points for ways to improve the German health-care system, to maintain and expand its strengths as well as to derive strategies for solving identified problems. A systematic review searching different databases [library catalogues, WorldCat (including MEDLINE and OAIster-search), German National Library, Google Scholar and others]. Search requests were addressed to English or German language publications for the time period 2000-2010 (an informal search was conducted in October 2011 for an update). Results of the identified studies were aggregated and main statements derived. In total, 13 publications assessing the German health-care system in an international comparison were identified. These comparisons are based on 377 measures. After aggregation, 244 substantially different indicators remained, which were dedicated to 14 categories. It became apparent that the German health-care system can be characterised by a high level of expenses, a well-developed health-care infrastructure as well as a high availability of personal and material resources. Outcome measures demonstrate heterogeneous results. It can be stated that, particularly in this field, there is potential for further improvement. The utilisation of health-care services is high, the access is mostly not regulated and out of pocket payments can pose a barrier for patients. Waiting times are not regarded as a major weakness. Although civic satisfaction seems to be acceptable, a large portion of the citizens calls for elementary modifications. Especially, more patient-centred health-care delivery should be addressed as well as management of information and the adoption of meaningful electronic

  18. Comparison of image quality between 70 kVp and 80 kVp: application to paediatric cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Durand, Sebastien [Centre Chirurgical Marie Lannelongue, Radiology Department, Le Plessis-Robinson (France); Paul, Jean-Francois [Institut Mutualiste Montsouris, Radiology Department, Paris (France)

    2014-12-15

    To evaluate noise level and contrast-to-noise ratio (CNR) with various kVp-mAs pairs producing the same computed tomography dose index (CTDI) value. The 80 kVp and new 70-kVp settings were compared. The noise was measured in 10 ovoid water phantoms with different diameters from 10 cm to 28 cm. Contrast was obtained from CTs of iodine-filled tubes. Spiral acquisition protocols at 70 kVp and 80 kVp, with the same CTDI, were applied. In the clinical study, two matched groups, each of 21 paediatric patients, underwent 70-kVp or 80-kVp ECG-gated iodinated-enhanced sequential CT. Noise was significantly higher with 70 kVp than 80-kVp settings for all phantom sizes. Estimated CNR with phantoms was higher at 70 kVp than 80 kVp, and the difference decreased from 17 % to 3 % as phantom size increased. The mean CNR in paediatric patients was 15.2 at 70 kVp and 14.3 at 80 kVp (ns). The CNR difference was significantly larger in the small-child subgroup. Noise level is slightly higher at the 70-kVp than the 80-kVp setting, but the CNR is higher, particularly for small children. Therefore, 70 kVp may be appropriate for contrast-enhanced CT examinations and 80 kVp for non-enhanced CT in small children. (orig.)

  19. TRENDS OF THE FACTORING TURNOVER IN INTERNATIONAL COMPARISONS

    Directory of Open Access Journals (Sweden)

    Éva DARABOS

    2017-05-01

    Full Text Available The factoring scheme was developed by the competition between the market operators and the need for the most favourable conditions of sale. The seller is constrained to provide loans on a broad scale therefore the seller may have liquidity problems. In cases of this kind, the seller can apply to a factoring company in order to access sources, instead of a bank loan. The factoring service has a price. Decision of the financial managers can largely contribute to choosing the appropriate funding form to retain the continuous liquidity situation of an enterprise. Aim of the article is to present the main tendencies of the factoring turnover in international comparisons, highlighting the characteristics of the financial service by its direction, sectorial distribution and customer size in Hungary. It has been estimated that the factoring financing approaches 10% of the short-term loan stocks of SMEs required from banks which indicates that the factoring is now far beyond the marginal financial service but it is an essential element of the short-term financing toolkit.

  20. RF SQUID in the nonhysteretic regime with k2Ql>1

    International Nuclear Information System (INIS)

    Dmitrenko, I.M.; Tsoi, G.M.; Shnyrkov, V.I.; Kartsovnik, V.V.

    1982-01-01

    Experimental measurements of current-voltage, current-phase, amplitude-frequency, phase-frequency, and signal characteristics of an rf SQUID operating at a frequency of 30 MHz in the nonhysteretic regime (1 = 2πL 0 I 0 /phi/sub o/ 2 Ql>1. Here I 0 is the critical current of the weak link, L 0 is the SQUID ring inductance, k is the coefficient of coupling of the SQUID ring to a resonant tank circuit of quality Q, and phi 0 is the magnetic flux quantum. A numerical analysis of the above characteristics for all relevant parameter values close to those occurring under experimental conditions was performed for qualitative comparison with theory. The main difference from the traditional nonhysteretic regime of SQUID operation (k 2 Q1 12 V/Wb for the single-valued region of the signal characteristics. The results suggest that considerable improvement of rf SQUID resolution is possible in the regime k 2 Ql>1

  1. How good are the internal conversion coefficients now?

    International Nuclear Information System (INIS)

    Raman, S.; Nestor, C.W. Jr.; Ichihara, A.; Trzhaskovskaya, M.B.

    2002-01-01

    To fully utilize experimental internal conversion coefficients, one needs a reliable calculation of theoretical values. We have assembled a set of 100 experimental conversion coefficients, 45 α K and 55 α T values, measured with an accuracy of better than 5%, and generated the corresponding theoretical values using two methods, relativistic Hartree-Fock-Slater (RHFS) and relativistic Dirac-Fock (DF). Extensive comparisons of the experimental values with the two sets of theoretical values show that the DF method is clearly superior to the RHFS method in the overall reproduction of the experimental internal conversion coefficients. We discuss in some detail the differences between various versions of these two theoretical approaches, with a view to understanding which of these differences are most critical to obtaining agreement with experiment

  2. Occupational radiation exposure in PWR: International comparison of some global indicators between 1975 and 1985

    International Nuclear Information System (INIS)

    Lochard, J.; Benedittini, M.

    1987-09-01

    This report presents the main results of an international comparative study of occupational radiation exposure in Pressurised Water Reactors (PWRs). The comparison is based on some synthetic indicators concerning both collective and mean individual exposures assessed for the following countries: Belgium, United-States, France, Japan, Federal Republic of Germany, Sweden and Switzerland. Information has been gained from the published literature and when it was possible, through direct correspondence with power station operators or national regulatory authorities. It concerns 120 reactors totalizing more than 900 reactor operating years. For the comparison, only reactors which were installed after 1974 have been considered, in order to have more homogeneous data representative of modern operating plants. Indicators calculated for the comparison are the collective and mean individual doses per reactor expressed either on a calendar year basis (from 1975 to 1985) or on a number of operating year basis (up to 11 years) [fr

  3. Internal friction in cold-rolled metallic glasses Cu50Ti50 and Ni78Si8B14

    International Nuclear Information System (INIS)

    Zolotukhin, I.V.; Khonik, V.A.; Ryabtseva, T.N.; Belyavskii, V.I.

    1989-01-01

    The influence of cold rolling on the low temperature (30 to 300 K) internal friction of metallic glasses Cu 50 Ti 50 and Ni 78 Si 8 B 14 is investigated. It is shown that cold rolling of both metallic glasses up to 2 to 6% results in the appearance of a high relaxation damping peak around 260 to 280 K. The internal friction background below the peak shows a strong amplitude dependence. In highly predeformed specimens (∼ 16%) the internal friction peak is absent. Electron irradiation (2 MeV, 10 19 cm -2 ) leads to the suppression of the deformation-induced internal friction peak. The results are interpreted in the framework of the dislocation models of plastic flow of metallic glasses. (author)

  4. 60-MW test using the 30-MW klystrons for the KEKB project

    Science.gov (United States)

    Fukuda, S.; Michizono, S.; Nakao, K.; Saito, Y.; Anami, S.

    1995-07-01

    The B-Factory is a future plan, requiring an energy upgrade of the KEK linac from 2.5 GeV to 8.0 GeV (KEKB Project). This paper describes the recent development of an S-band high-power pulse klystron to be used as the PF-linac rf-source of the B-Factory. This tube is a modified version of the existing 30-MW tube, which produces 51 MW at a 310 kV beam voltage by optimizing the focusing magnetic field. In order to increase the reliability, the cathode diameter, the gun housing, and the insulation ceramic-seal were enlarged. This tube was redesigned so as to have the same characteristics as the test results of 30-MW tubes at a higher applied voltage without changing the rf interaction region. Four prototype tubes have been manufactured; final test results showed that these new tubes produce an output power of more than 50 MW at 310 kV with an efficiency of 46%. Recently this tube has produced more than 60 MW at a 350 kV beam voltage for a demonstration test. A comparison between the FCI-code prediction and the test results is also given in this paper.

  5. Large Steel Tank Fails and Rockets to Height of 30 meters − Rupture Disc Installed Incorrectly

    OpenAIRE

    Hedlund, Frank H.; Selig, Robert S.; Kragh, Eva K.

    2016-01-01

    At a brewery, the base plate-to-shell weld seam of a 90-m3 vertical cylindrical steel tank failed catastrophically. The 4 ton tank “took off” like a rocket leaving its contents behind, and landed on a van, crushing it. The top of the tank reached a height of 30 m. The internal overpressure responsible for the failure was an estimated 60 kPa. A rupture disc rated at <50 kPa provided overpressure protection and thus prevented the tank from being covered by the European Pressure Equipment Dir...

  6. K-U-Th systematics of terrestrial igneous rocks for planetological comparisons: volcanic rocks of the Earth oceanic island arc and Venus surface material

    International Nuclear Information System (INIS)

    Nikolaeva, O.V.

    1997-01-01

    Principles of the formation o data base for 339 samples of oceanic island arc (OIA) igneous rocks of the Earth available in literature are described as well as of the formation of fresh rock sample, characteristics of this sample, and K-U-Th-systematics of the fresh igneous rocks of Earth OIA. Results of comparison of the Venus measured rocks and Earth OIA rocks by K, U, Th

  7. Study of CP violation in B--/+ -> Dh(-/+) (h = K,pi) with the modes D -> K--/+pi(+/-)pi(0), D -> pi(+)pi(-)pi(0) and D -> K+K-pi(0)

    NARCIS (Netherlands)

    Aaij, R.; Adeva, B.; Adinolfi, M.; Affolder, A.; Ajaltouni, Z.; Akar, S.; Albrecht, J.; Alessio, F.; Alexander, M.; Ali, S.; Alkhazov, G.; Alvarez Cartelle, P.; Alves, A. A.; Amato, S.; Amerio, S.; Amhis, Y.; An, L.; Anderlini, L.; Andreotti, M.; Andrews, J. E.; Appleby, R. B.; Aquines Gutierrez, O.; Archilli, F.; d'Argent, P.; Artamonov, A.; Artuso, M.; Aslanides, E.; Auriemma, G.; Baalouch, M.; Bachmann, S.; Back, J. J.; Badalov, A.; Baesso, C.; Baldini, W.; Barlow, R. J.; Barschel, C.; Barsuk, S.; Barter, W.; Batozskaya, V.; Battista, V.; Beaucourt, L.; Beddow, J.; Bedeschi, F.; Bediaga, I.; Bel, L. J.; Belyaev, I.; Ben-Haim, E.; Onderwater, C. J. G.; Pellegrino, A.; Tolk, S.

    2015-01-01

    An analysis of the decays of B--/+ -> DK -/+ and B--/+ -> D pi(-/+) is presented in which the D meson is reconstructed in the three-body final states K--/+pi(+/-)pi(0), pi(+)pi(-)pi(0) and K+K-pi(0). Using data from LHCb corresponding to an integrated luminosity of 3.0 fb(-1) of pp collisions,

  8. Johnson Noise Thermometry in the range 505 K to 933 K

    Science.gov (United States)

    Tew, Weston; Labenski, John; Nam, Sae Woo; Benz, Samuel; Dresselhaus, Paul; Martinis, John

    2006-03-01

    The International Temperature Scale of 1990 (ITS-90) is an artifact-based temperature scale, T90, designed to approximate thermodynamic temperature T. The thermodynamic errors of the ITS-90, characterized as the value of T-T90, only recently have been quantified by primary thermodynamic methods. Johnson Noise Thermometry (JNT) is a primary method which can be applied over wide temperature ranges, and NIST is currently using JNT to determine T-T90 in the range 505 K to 933 K, overlapping both acoustic gas-based and radiation-based thermometry. Advances in digital electronics have now made the computationally intensive processing required for JNT viable using noise voltage correlation in the frequency domain. We have also optimized the design of the 5-wire JNT temperature probes to minimize electromagnetic interference and transmission line effects. Statistical uncertainties under 50 μK/K are achievable using relatively modest bandwidths of ˜100 kHz. The NIST JNT system will provide critical data for T-T90 linking together the highly accurate acoustic gas-based data at lower temperatures with the higher-temperature radiation-based data, forming the basis for a new International Temperature Scale with greatly improved thermodynamic accuracy.

  9. Domestic/family violence death reviews: an international comparison.

    Science.gov (United States)

    Bugeja, Lyndal; Dawson, Myrna; McIntyre, Sara-Jane; Walsh, Carolyn

    2015-04-01

    Domestic/Family Violence Death Reviews (D/FVDRs) have been established in a number of high-income countries since 1990 as a mechanism to inform prevention-focused interventions to reduce domestic/family violence. D/FVDRs differ in their structure, governance, case identification processes and inclusion criteria, review measures, and outputs. Outside of the United States, the extent of heterogeneity across and within countries has not been explored. This study comprised an international comparison of D/FVDRs and their core elements to inform the establishment of D/FVDRs in other developed countries, and potentially low- and middle-income countries where violence is a leading cause of death. Such a review is also a necessary foundation for any future evaluation D/FVDRs. The review identified 71 jurisdictions where a D/FVDRs had been established in the past two decades, 25 of which met the inclusion criteria. All D/FVDRs examined stated a reduction in deaths as a goal of the review process; however, none reported an actual reduction. The focus of the D/FVDRs examined was on intimate partner homicides; however, more recently established D/FVDRs include other familial relationships. Almost one third of the D/FVDRs examined reported changes to the domestic/family system that occurred as a result of recommendations made from the review process. While similar in many ways, D/FVDRs differ along a number of important dimensions that make it difficult to identify best practices for jurisdictions considering the establishment of such an initiative. To share knowledge, existing networks should be expanded nationally and internationally to include jurisdictions that may be considering this initiative. © The Author(s) 2013.

  10. DPW-VI Results Using FUN3D with Focus on k-kL-MEAH2015 (k-kL) Turbulence Model

    Science.gov (United States)

    Abdol-Hamid, K. S.; Carlson, Jan-Renee; Rumsey, Christopher L.; Lee-Rausch, Elizabeth M.; Park, Michael A.

    2017-01-01

    The Common Research Model wing-body configuration is investigated with the k-kL-MEAH2015 turbulence model implemented in FUN3D. This includes results presented at the Sixth Drag Prediction Workshop and additional results generated after the workshop with a nonlinear Quadratic Constitutive Relation (QCR) variant of the same turbulence model. The workshop provided grids are used, and a uniform grid refinement study is performed at the design condition. A large variation between results with and without a reconstruction limiter is exhibited on "medium" grid sizes, indicating that the medium grid size is too coarse for drawing conclusions in comparison with experiment. This variation is reduced with grid refinement. At a fixed angle of attack near design conditions, the QCR variant yielded decreased lift and drag compared with the linear eddy-viscosity model by an amount that was approximately constant with grid refinement. The k-kL-MEAH2015 turbulence model produced wing root junction flow behavior consistent with wind tunnel observations.

  11. A K Shukla

    Indian Academy of Sciences (India)

    Cars Beyond Otto's Internal Combustion Engines · A K Shukla · More Details Fulltext PDF. Volume 11 Issue 7 July 2006 pp 42-50 General Article. Turning Sunlight into Electricity - Inorganic Solar Cells and Beyond · A K Shukla · More Details Fulltext PDF. Volume 15 Issue 12 December 2010 pp 1068-1072 General Article.

  12. On Developments of k-τ and k-ω Models for Near-Wall Turbulence of Engineering Duct Flows

    DEFF Research Database (Denmark)

    Rokni, Masoud; Sundén, Bengt

    2009-01-01

    -epsilon model namely, the lack of natural boundary conditions. Based on idea of Kolmogorov time-scale a boundary condition at the wall is also proposed. A bounded k-omega model for near wall turbulence is also presented and comparison with other well established two-equation models (k-epsilon model and Wilcox k...

  13. "I Am Chelsea Manning": Comparison of Gendered Representation of Private Manning in U.S. and International News Media.

    Science.gov (United States)

    Hackl, Andrea M; Becker, Amy B; Todd, Maureen E

    2016-01-01

    On August 22, 2013, Bradley Manning released a statement requesting to be referred to as female. In the following days, the news media discussed whether language should shift toward a female representation. Using quantitative content analysis and qualitative contextual analysis, this study analyzed whether U.S. and international newspapers (N = 197) acknowledged Manning's request to be referred to as "Chelsea" in the two weeks after the statement. Results suggest that the mainstream press was hesitant in shifting toward a female representation. A comparison of international and U.S. newspapers suggests that the U.S. press lagged behind international coverage using a female depiction.

  14. Accurate quantification of supercoiled DNA by digital PCR

    Science.gov (United States)

    Dong, Lianhua; Yoo, Hee-Bong; Wang, Jing; Park, Sang-Ryoul

    2016-01-01

    Digital PCR (dPCR) as an enumeration-based quantification method is capable of quantifying the DNA copy number without the help of standards. However, it can generate false results when the PCR conditions are not optimized. A recent international comparison (CCQM P154) showed that most laboratories significantly underestimated the concentration of supercoiled plasmid DNA by dPCR. Mostly, supercoiled DNAs are linearized before dPCR to avoid such underestimations. The present study was conducted to overcome this problem. In the bilateral comparison, the National Institute of Metrology, China (NIM) optimized and applied dPCR for supercoiled DNA determination, whereas Korea Research Institute of Standards and Science (KRISS) prepared the unknown samples and quantified them by flow cytometry. In this study, several factors like selection of the PCR master mix, the fluorescent label, and the position of the primers were evaluated for quantifying supercoiled DNA by dPCR. This work confirmed that a 16S PCR master mix avoided poor amplification of the supercoiled DNA, whereas HEX labels on dPCR probe resulted in robust amplification curves. Optimizing the dPCR assay based on these two observations resulted in accurate quantification of supercoiled DNA without preanalytical linearization. This result was validated in close agreement (101~113%) with the result from flow cytometry. PMID:27063649

  15. Proceedings of the International Association for Development of the Information Society (IADIS) International Conference on Cognition and Exploratory Learning in the Digital Age (CELDA) (13th, Mannheim, Germany, October 28-30, 2016)

    Science.gov (United States)

    Sampson, Demetrios G., Ed.; Spector, J. Michael, Ed.; Ifenthaler, Dirk, Ed.; Isaias, Pedro, Ed.

    2016-01-01

    These proceedings contain the papers of the 13th International Conference on Cognition and Exploratory Learning in the Digital Age (CELDA 2016), October 28-30, 2016, which has been organized by the International Association for Development of the Information Society (IADIS), co-organized by the University of Mannheim, Germany, and endorsed by the…

  16. END 2014: International Conference on Education and New Developments. Conference Proceedings (Madrid, Spain, June 28-30, 2014)

    Science.gov (United States)

    Carmo, Mafalda, Ed.

    2014-01-01

    We welcome you to the International Conference on Education and New Developments 2014, taking place in Madrid, Spain, from 28 to 30 of June, 2014. Education, as an important right in our contemporary world, began since we exist. Knowledge and skills were passed by adults to the young, and cultures began to extend their experiences through various…

  17. Cooling of electrically insulated high voltage electrodes down to 30 mK Kühlung von elektrisch isolierten Hochspannungselektroden bis 30 mK

    CERN Document Server

    Eisel, Thomas; Bremer, J

    2011-01-01

    The Antimatter Experiment: Gravity, Interferometry, Spectroscopy (AEGIS) at the European Organization for Nuclear Research (CERN) is an experiment investigating the influence of earth’s gravitational force upon antimatter. To perform precise measurements the antimatter needs to be cooled to a temperature of 100 mK. This will be done in a Penning trap, formed by several electrodes, which are charged with several kV and have to be individually electrically insulated. The trap is thermally linked to a mixing chamber of a 3He-4He dilution refrigerator. Two link designs are examined, the Rod design and the Sandwich design. The Rod design electrically connects a single electrode with a heat exchanger, immersed in the helium of the mixing chamber, by a copper pin. An alumina ring and the helium electrically insulate the Rod design. The Sandwich uses an electrically insulating sapphire plate sandwiched between the electrode and the mixing chamber. Indium layers on the sapphire plate are applied to improve the ther...

  18. Avoidance of Vitamin K-Rich Foods Is Common among Warfarin Users and Translates into Lower Usual Vitamin K Intakes.

    Science.gov (United States)

    Leblanc, Cristina; Dubé, Marie-Pierre; Presse, Nancy; Dumas, Stéphanie; Nguyen, Mimosa; Rouleau-Mailloux, Étienne; Perreault, Sylvie; Ferland, Guylaine

    2016-06-01

    Warfarin users should aim for stable daily vitamin K intakes. However, some studies report that patients are often advised to avoid eating green vegetables. Whether this advice impacts vitamin K intakes is unknown. Our aim was to describe the nature and sources of vitamin K-related dietary recommendations that patients received at the initiation of warfarin therapy, assess their adherence to these recommendations, and examine whether usual vitamin K intakes vary according to these recommendations. We conducted a retrospective cohort study with patients enrolled in the Québec Warfarin Cohort Study. Patients were asked to report dietary recommendations they had received at warfarin initiation and their adherence to these recommendations. Usual vitamin K intakes were assessed using a validated semi-quantitative food frequency questionnaire. Three hundred seventeen patients aged 36 to 97 years who initiated warfarin between 2011 and 2012 and were treated for 12 months or longer with a target international normalized ratio range of 2.0 to 3.0 or 2.5 to 3.5. Patients were classified according to vitamin K-related recommendations reported: limit or avoid vitamin K-rich foods; aim for stable consumption of vitamin K-rich foods; or no vitamin K-related advice. A one-way analysis of covariance was used to compare mean usual vitamin K intakes between patients after adjustment for covariates. Most patients (68%) reported being advised to limit or avoid vitamin K-rich foods, particularly green vegetables, 10% reported being advised to aim for stable consumption of vitamin K-rich foods, and 22% did not recall receiving any vitamin K-related recommendation. Mean usual vitamin K intakes of patients adhering to the recommendation to limit or avoid vitamin K-rich foods was 35% to 46% lower than those of other patients (Pvitamin K-rich foods, which translated into lower usual vitamin K intakes. Copyright © 2016 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All

  19. Regional correlations of VS30 averaged over depths less than and greater than 30 meters

    Science.gov (United States)

    Boore, David M.; Thompson, Eric M.; Cadet, Héloïse

    2011-01-01

    Using velocity profiles from sites in Japan, California, Turkey, and Europe, we find that the time-averaged shear-wave velocity to 30 m (VS30), used as a proxy for site amplification in recent ground-motion prediction equations (GMPEs) and building codes, is strongly correlated with average velocities to depths less than 30 m (VSz, with z being the averaging depth). The correlations for sites in Japan (corresponding to the KiK-net network) show that VSz is systematically larger for a given VSz than for profiles from the other regions. The difference largely results from the placement of the KiK-net station locations on rock and rocklike sites, whereas stations in the other regions are generally placed in urban areas underlain by sediments. Using the KiK-net velocity profiles, we provide equations relating VS30 to VSz for z ranging from 5 to 29 m in 1-m increments. These equations (and those for California velocity profiles given in Boore, 2004b) can be used to estimate VS30 from VSz for sites in which velocity profiles do not extend to 30 m. The scatter of the residuals decreases with depth, but, even for an averaging depth of 5 m, a variation in logVS30 of ±1 standard deviation maps into less than a 20% uncertainty in ground motions given by recent GMPEs at short periods. The sensitivity of the ground motions to VS30 uncertainty is considerably larger at long periods (but is less than a factor of 1.2 for averaging depths greater than about 20 m). We also find that VS30 is correlated with VSz for z as great as 400 m for sites of the KiK-net network, providing some justification for using VS30 as a site-response variable for predicting ground motions at periods for which the wavelengths far exceed 30 m.

  20. Comparison BIPM.RI(I)-K8 of high dose-rate Ir-192 brachytherapy standards for reference air kerma rate of the VSL and the BIPM

    DEFF Research Database (Denmark)

    Alvarez, J.T.; De Pooter, J.A.; Andersen, Claus E.

    2014-01-01

    An indirect comparison of the standards for reference air kerma rate for 192Ir high dose rate brachytherapy sources of the Dutch Metrology Institute (VSL), The Netherlands, and of the Bureau International des Poids et Mesures (BIPM) was carried out at the VSL in November 2009. The comparison resu...

  1. Nuclear critical safety analysis for UX-30 transport of freight package

    International Nuclear Information System (INIS)

    Quan Yanhui; Zhou Qi; Yin Shenggui

    2014-01-01

    The nuclear critical safety analysis and evaluation for UX-30 transport freight package in the natural condition and accident condition were carried out with MONK-9A code and MCNP code. Firstly, the critical benchmark experiment data of public in international were selected, and the deflection and subcritical limiting value with MONK-9A code and MCNP code in calculating same material form were validated and confirmed. Secondly, the neutron efficiency multiplication factors in the natural condition and accident condition were calculated and analyzed, and the safety in transport process was evaluated by taking conservative suppose of nuclear critical safety. The calculation results show that the max value of k eff for UX-30 transport freight package is less than the subcritical limiting value, and the UX-30 transport freight package is in the state of subcritical safety. Moreover, the critical safety index (CSI) for UX-30 package can define zero based on the definition of critical safety index. (authors)

  2. Quantitative measurement of membrane Na{sup +}-K{sup +} ATPase activity using thallium-201: comparison with rubidium-86

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Tae; Shon, Sang Kyun; Lee, Kyu Bo [School of Medicine, Kyungpook National Univ., Taegu (Korea, Republic of); Lee, In Kyu [School of Medicine, Kyemyung Univ., Taegu (Korea, Republic of)

    1998-06-01

    Na{sup +}-K{sup +} ATPase activity has been estimated by the degree of inhibition of cation transport by cardiac glycosides (ouabain) using Rb-86 as a substrate. The biological characteristics of Tl-201 is known to be similar to those of potassium as a transport substrate in the presence of glucose, insulin or phobol myristate acetate (PMA). The purpose of this study was to measure ouabain sensitive Na{sup +}-K{sup +} ATPase activity using Tl-201 and compare with that using Rb-86. Smooth muscle cells isolated from rat aorta or human placental umbilical artery were cultured, and used to measure cellular Na{sup +}-K{sup +} ATPase activity. Na{sup +}-K{sup +} ATPase activity was measured as a percentage decrease in cellular uptake of Tl-201 or Rb-86 by ouabain under the presence of glucose, insulin or PMA in media. Na{sup +}-K{sup +} ATPase activity measured with Tl-201, as a transport substrate, was not different from those measured with Rb-86 in rat or human smooth muscle cell preparation. Incubation with high concentration glucose resulted in about 30% decrease in enzyme activity. In contrast, insulin or PMA resulted in 50-70% or 28% increase from baseline activity, respectively. These results suggests that Tl-201 could replace Rb-86 in measurement of ouabain sensitive Na{sup +}-K{sup +} ATPase activity in vitro. High level of glucose concentration decreased cellular Na{sup +}-K{sup +} ATPase activity, but insulin or PMA increased it.

  3. Hemodialysis practice patterns in the Russia Dialysis Outcomes and Practice Patterns Study (DOPPS), with international comparisons.

    Science.gov (United States)

    Bikbov, Boris; Bieber, Brian; Andrusev, Anton; Tomilina, Natalia; Zemchenkov, Alexander; Zhao, Junhui; Port, Friedrich; Robinson, Bruce; Pisoni, Ronald

    2017-07-01

    There is little comparable information about hemodialysis (HD) practices in low- and middle income countries, including Russia. Evaluation of HD in Russia and its international comparisons could highlight factors providing opportunities for improvement. We examined treatment patterns for 481 prevalent HD patients in 20 Russian facilities, and compared them to contemporary data for 8512 patients from 311 facilities in seven European countries, Japan, and North America. Data were collected according to the uniform methodology of the Dialysis Outcomes and Practice Patterns Study, phase 5. Compared to other regions, Russian patients were younger (mean age 53.4 years), had a lower percent of males (52.5%), higher arteriovenous fistula use (89.7%), and longer treatment time (mean: 252 minutes, SD: 37 minutes). Mean single pool Kt/V was 1.49 (SD 0.58). Prescription of dialysate calcium 3.5 mEq/L and aluminum-based phosphate binders were high (15.2% and 17.6% of patients, respectively), while intravenous vitamin D and cinacalcet were low (3.3% and 2.2%, respectively). The percents with parathyroid hormone >600 pg/mL (30.9%) and serum phosphate >1.78 mmol/L (37.7%) were high. Use of erythropoetin stimulating agents (78%) was lower, but hemoglobin, ferritin, and transferrin saturation were generally comparable to North America and Europe. These detailed data for hemodialysis in Russia demonstrate that many practice patterns contrasted sharply to those in Europe, Japan, and North America, while other features were similar. Our analysis revealed several positive and some less favorable treatment patterns in Russia that represent opportunities for improving patient care and outcomes. © 2016 International Society for Hemodialysis.

  4. Advances in fast reactor technology. Proceedings of the 30. meeting of the International Working Group on Fast Reactors

    International Nuclear Information System (INIS)

    1998-04-01

    Individual States were largely responsible for early developments in experimental and prototype liquid metal fast reactors (LMFRs). However, for development of advanced LMFRs, international co-operation plays an important role. The IAEA seeks to promote such co-operation. For R and D incorporating innovative features, international co-operation allows pooling of resources and expertise in areas of common interest. Information on experience gained from R and D, and from the operation and construction of fast reactors, has been reviewed periodically by the International Working Group on Fast Reactors (IWGFR). These proceedings contain updated a new information on the status of LMFR development, as reported at the 30th meeting of the IWGFR, held in Beijing, China, from 13 to 16 May 1997

  5. Advances in fast reactor technology. Proceedings of the 30. meeting of the International Working Group on Fast Reactors

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-04-01

    Individual States were largely responsible for early developments in experimental and prototype liquid metal fast reactors (LMFRs). However, for development of advanced LMFRs, international co-operation plays an important role. The IAEA seeks to promote such co-operation. For R and D incorporating innovative features, international co-operation allows pooling of resources and expertise in areas of common interest. Information on experience gained from R and D, and from the operation and construction of fast reactors, has been reviewed periodically by the International Working Group on Fast Reactors (IWGFR). These proceedings contain updated a new information on the status of LMFR development, as reported at the 30th meeting of the IWGFR, held in Beijing, China, from 13 to 16 May 1997. Refs,figs,tabs.

  6. Comparative analysis of elemental components in airborne particulate matter by k0-NAA methods

    International Nuclear Information System (INIS)

    Chung, Yong-Sam; Moon, Jong-Hwa; Cho, Hyun-Je; Kim, Young-Jin

    2005-01-01

    A comparison of the analytical data obtained by three k 0 -NAA software programs was carried out using both the airborne particulate matter collected from an urban site and the certified reference materials of the air filter and urban dust to evaluate the performance of the analysis. The individual k 0 -NAA standardization methods of three countries, Korea, China and Vietnam which had been modified from the well established k 0 -program were used for the comparative analysis. The measured concentrations of 30 elements from the two kinds of air samples based on this software were in agreement with each other within about 20% analytical error except for a few elements. By contrast, the results of China and Vietnam were moderately higher than that of Korea due to a systematic error associated with the detection efficiency, gamma peak analysis and geometric effect

  7. Cancer Drugs: An International Comparison of Postlicensing Price Inflation.

    Science.gov (United States)

    Savage, Philip; Mahmoud, Sarah; Patel, Yogin; Kantarjian, Hagop

    2017-06-01

    The cost of cancer drugs forms a rising proportion of health care budgets worldwide. A number of studies have examined international comparisons of initial cost, but there is little work on postlicensing price increases. To examine this, we compared cancer drug prices at initial sale and subsequent price inflation in the United States and United Kingdom and also reviewed relevant price control mechanisms. The 10 top-selling cancer drugs were selected, and their prices at initial launch and in 2015 were compared. Standard nondiscounted prices were obtained from the relevant annual copies of the RED BOOK and the British National Formulary. At initial marketing, prices were on average 42% higher in the United States than in the United Kingdom. After licensing in the United States, all 10 drugs had price rises averaging an overall annual 8.8% (range, 1.4% to 24.1%) increase. In comparison, in the United Kingdom, six drugs had unchanged prices, two had decreased prices, and two had modest price increases. The overall annual increase in the United Kingdom was 0.24%. Cancer drug prices are rising substantially, both at their initial marketing price and, in the United States, at postlicensing prices. In the United Kingdom, the Pharmaceutical Price Regulation Scheme, an agreement between the government and the pharmaceutical industry, controls health care costs while allowing a return on investment and funds for research. The increasing costs of cancer drugs are approaching the limits of sustainability, and a similar government-industry agreement may allow stability for both health care provision and the pharmaceutical industry in the United States.

  8. Novel Semi-Direct OH Reactivity (kOH) Measurements by Chemical Ionization Mass Spectrometry during a Chamber Instrument Comparison Campaign and Continuous Ambient Air Sampling at a Central European GAW Station

    Science.gov (United States)

    Muller, J.; Kubistin, D.; Elste, T.; Plass-Duelmer, C.; Claude, A.; Englert, J.; Holla, R.; Fuchs, H.; Hofzumahaus, A.; Holland, F.; Novelli, A.; Tillmann, R.; Wegener, R.; Rohrer, F.; Yu, Z.; Bohn, B.; Williams, J.; Pfannerstill, E.; Edtbauer, A.; Kluepfel, T.

    2016-12-01

    Total OH reactivity (kOH) has been recognized as a useful measure to gauge the potential atmospheric oxidation capacity and a few different in-situ measurement techniques have been developed over the last 15 years. Here results are presented from a novel semi-direct method developed by the German Weather Service (DWD) utilizing a chemical ionization mass spectrometer (CIMS). Recently in April 2016, the CIMS system participated in a half-blind kOH instrument comparison campaign at the Forschungszentrum Jülich (FZJ) SAPHIR chamber. Experiments provided controlled conditions with a range of different VOC mixtures and varying NOx levels, representing environments dominated by biogenic or urban emissions. Alongside CIMS, kOH was also measured by systems using the comparative reactivity method (CRM) and the pump-probe technique with OH detection. The intercomparison revealed a good performance of CIMS at lower OH reactivities (0-15 s-1), a range for which the instrumental set up was optimized. Limitations of the CIMS system consist of an upper limit for kOH detection and the need for applying a chemical correction function as a result of instrument-internal HOx recycling. Findings and instrument parameters obtained from the FZJ SAPHIR campaign and flow tube experiments are then applied to ambient air kOH measurements at the Meteorological Observatory Hohenpeissenberg (MOHp), Germany. The CIMS instrument is used there for long-term measurements of OH, H2SO4, ROx and kOH. Here, we show ambient air kOH measurements, interpreted in conjunction with volatile organic compounds (VOC) and inorganic trace gases also measured at the GAW station Hohenpeissenberg. These observations provide a unique dataset to investigate turnover rates and seasonal cycles of reactive trace gases, i.e. sources that make up total OH reactivity in this central European, rural setting.

  9. Comparison of acquisition time and dose for late gadolinium enhancement imaging at 3.0 T in patients with chronic myocardial infarction using Gd-BOPTA

    International Nuclear Information System (INIS)

    Doltra, A.; Skorin, A.; Gebker, R.; Klein, C.; Fleck, E.; Kelle, S.; Hamdan, A.; Schnackenburg, B.; Nagel, E.

    2014-01-01

    To compare contrast doses and acquisition times for late gadolinium enhancement (LGE) imaging at 3.0 T using gadobenate dimeglumine (Gd-BOPTA) in patients with chronic myocardial infarction. Thirty-four patients with chronic myocardial infarction were randomised to 0.10, 0.15 and 0.20 mmol/kg of Gd-BOPTA. T1-weighted inversion recovery gradient echo sequences were performed at 5, 10, 15 and 20 min post-administration of contrast in a 3.0-T scanner. Scar-to-myocardium contrast-to-noise ratio (CNR), scar-to-blood CNR, scar size and image quality were assessed. Imaging at 5 min was associated with a lower scar-to-blood CNR in comparison to 10, 15 and 20 min at 0.10 mmol/kg, and in comparison to 15 and 20 min at 0.20 mmol/kg. At 0.10-mmol/kg, imaging at 5 min yielded smaller infarct sizes in comparison to 15 and 20 min. Finally, at 0.20-mmol/kg, imaging at 5 min was associated with poorer image quality in comparison to later times. In LGE imaging at 3.0 T, low doses of Gd-BOPTA perform equally well as higher doses. Early acquisition (5 min) is associated with lower infarct sizes and image quality. Studies with sufficient diagnostic quality can be obtained after 10 min using 0.10 mmol/kg Gd-BOPTA. (orig.)

  10. B K Singh

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. B K Singh. Articles written in Bulletin of Materials Science. Volume 30 Issue 3 June 2007 pp 235-238 Clay Materials. Instrumental characterization of clay by XRF, XRD and FTIR · Preeti Sagar Nayak B K Singh · More Details Abstract Fulltext PDF. Instrumental characterizations ...

  11. 26 CFR 1.401(k)-2 - ADP test.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 5 2010-04-01 2010-04-01 false ADP test. 1.401(k)-2 Section 1.401(k)-2 Internal... TAXES Pension, Profit-Sharing, Stock Bonus Plans, Etc. § 1.401(k)-2 ADP test. (a) Actual deferral percentage (ADP) test—(1) In general—(i) ADP test formula. A cash or deferred arrangement satisfies the ADP...

  12. International Comparisons of Behavioral and Emotional Problems in Preschool Children: Parents’ Reports From 24 Societies

    Science.gov (United States)

    Rescorla, Leslie A.; Achenbach, Thomas M.; Ivanova, Masha Y.; Harder, Valerie S.; Otten, Laura; Bilenberg, Niels; Bjarnadottir, Gudrun; Capron, Christiane; De Pauw, Sarah S. W.; Dias, Pedro; Dobrean, Anca; Döpfner, Manfred; Duyme, Michel; Eapen, Valsamma; Erol, Nese; Esmaeili, Elaheh Mohammad; Ezpeleta, Lourdes; Frigerio, Alessandra; Fung, Daniel S. S.; Gonçalves, Miguel; Guđmundsson, Halldór; Jeng, Suh-Fang; Jusiené, Roma; Kim, Young Ah; Kristensen, Solvejg; Liu, Jianghong; Lecannelier, Felipe; Leung, Patrick W. L.; Machado, Bárbara César; Montirosso, Rosario; Oh, Kyung Ja; Ooi, Yoon Phaik; Plück, Julia; Pomalima, Rolando; Pranvera, Jetishi; Schmeck, Klaus; Shahini, Mimoza; Silva, Jaime R.; Simsek, Zeynep; Sourander, Andre; Valverde, José; van der Ende, Jan; Van Leeuwen, Karla G.; Wu, Yen-Tzu; Yurdusen, Sema; Zubrick, Stephen R.; Verhulst, Frank C.

    2014-01-01

    International comparisons were conducted of preschool children’s behavioral and emotional problems as reported on the Child Behavior Checklist for Ages 1½–5 by parents in 24 societies (N =19,850). Item ratings were aggregated into scores on syndromes; Diagnostic and Statistical Manual of Mental Disorders–oriented scales; a Stress Problems scale; and Internalizing, Externalizing, and Total Problems scales. Effect sizes for scale score differences among the 24 societies ranged from small to medium (3–12%). Although societies differed greatly in language, culture, and other characteristics, Total Problems scores for 18 of the 24 societies were within 7.1 points of the omnicultural mean of 33.3 (on a scale of 0–198). Gender and age differences, as well as gender and age interactions with society, were all very small (effect sizes societies, correlations between mean item ratings averaged .78, and correlations between internal consistency alphas for the scales averaged .92, indicating that the rank orders of mean item ratings and internal consistencies of scales were very similar across diverse societies. PMID:21534056

  13. Intracellular Requirements for Passive Proton Transport through the Na+,K+-ATPase.

    Science.gov (United States)

    Stanley, Kevin S; Meyer, Dylan J; Gatto, Craig; Artigas, Pablo

    2016-12-06

    The Na + ,K + -ATPase (NKA or Na/K pump) hydrolyzes one ATP to exchange three intracellular Na+ (Na + i ) for two extracellular K+ (K + o ) across the plasma membrane by cycling through a set of reversible transitions between phosphorylated and dephosphorylated conformations, alternately opening ion-binding sites externally (E2) or internally (E1). With subsaturating [Na + ] o and [K + ] o , the phosphorylated E2P conformation passively imports protons generating an inward current (I H ), which may be exacerbated in NKA-subunit mutations associated with human disease. To elucidate the mechanisms of I H , we studied the effects of intracellular ligands (transported ions, nucleotides, and beryllium fluoride) on I H and, for comparison, on transient currents measured at normal Na + o (Q Na ). Utilizing inside-out patches from Xenopus oocytes heterologously expressing NKA, we observed that 1) in the presence of Na + i , I H and Q Na were both activated by ATP, but not ADP; 2) the [Na + ] i dependence of I H in saturating ATP showed K 0.5,Na  = 1.8 ± 0.2 mM and the [ATP] dependence at saturating [Na + ] i yielded K 0.5,ATP  = 48 ± 11 μM (in comparison, Na + i -dependent Q Na yields K 0.5,Na  = 0.8 ± 0.2 mM and K 0.5,ATP  = 0.43 ± 0.03 μM; 3) ATP activated I H in the presence of K + i (∼15% of the I H observed in Na + i ) only when Mg 2+ i was also present; and 4) beryllium fluoride induced maximal I H  even in the absence of nucleotide. These data indicate that I H occurs when NKA is in an externally open E2P state with nucleotide bound, a conformation that can be reached through forward Na/K pump phosphorylation of E1, with Na + i and ATP, or by backward binding of K + i to E1, which drives the pump to the occluded E2(2K), where free P i (at the micromolar levels found in millimolar ATP solutions) promotes external release of occluded K + by backdoor NKA phosphorylation. Maximal I H through beryllium-fluorinated NKA indicates that this complex mimics ATP

  14. Angle comparison using an autocollimator

    Science.gov (United States)

    Geckeler, Ralf D.; Just, Andreas; Vasilev, Valentin; Prieto, Emilio; Dvorácek, František; Zelenika, Slobodan; Przybylska, Joanna; Duta, Alexandru; Victorov, Ilya; Pisani, Marco; Saraiva, Fernanda; Salgado, Jose-Antonio; Gao, Sitian; Anusorn, Tonmueanwai; Leng Tan, Siew; Cox, Peter; Watanabe, Tsukasa; Lewis, Andrew; Chaudhary, K. P.; Thalmann, Ruedi; Banreti, Edit; Nurul, Alfiyati; Fira, Roman; Yandayan, Tanfer; Chekirda, Konstantin; Bergmans, Rob; Lassila, Antti

    2018-01-01

    Autocollimators are versatile optical devices for the contactless measurement of the tilt angles of reflecting surfaces. An international key comparison (KC) on autocollimator calibration, EURAMET.L-K3.2009, was initiated by the European Association of National Metrology Institutes (EURAMET) to provide information on the capabilities in this field. The Physikalisch-Technische Bundesanstalt (PTB) acted as the pilot laboratory, with a total of 25 international participants from EURAMET and from the Asia Pacific Metrology Programme (APMP) providing measurements. This KC was the first one to utilise a high-resolution electronic autocollimator as a standard. In contrast to KCs in angle metrology which usually involve the full plane angle, it focused on relatively small angular ranges (+/-10 arcsec and +/-1000 arcsec) and step sizes (10 arcsec and 0.1 arcsec, respectively). This document represents the approved final report on the results of the KC. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. [Expression of JAK2V617F and MPLW515L/K mutation in 30 suspected cases of early myeloproliferative disorders].

    Science.gov (United States)

    Fan, Zheng; Zhang, Ri; Shen, Yi-Min; Fei, Hai-Rong; Zhu, Zi-Ling; Cen, Jian-Nong

    2008-09-01

    To investigate the prevalence of JAK2V617F and MPLW515L/K mutation in patients with slightly elevated platelets (BPC) or hemoglobin (Hb) not meeting the criteria of polycythemia vera (PV) or essential thrombocythemia (ET). Genomic DNA from bone marrow or blood mononuclear cells was screened with allele specific polymerase chain reaction (AS-PCR) for JAK2V617F and MPLW515L/K mutation. The history of thrombosis was assessed retrospectively by patients files. Of 30 patients, 14 (46.7%) were positive for the JAK2V617F mutation, none of them had the MPLW515L/ K. Five of these 14 patients had a history of thrombosis. Follow-up results were available in 22 patients. Among them, 12 patients with JAK2V617F mutation turned out to be MPD in 6-24 months; only 2 out of 10 patients without this mutation evolved to MPD. JAK2V617F mutation could be one of the diagnosis criteria of early MPD. No MPLW515L/K expression was found in early MPD.

  16. Canadian Policy Responses to International Comparison Testing

    Science.gov (United States)

    Volante, Louis

    2013-01-01

    This paper examines policy responses across Canada to international student assessment programs such as the program for international student assessment, trends in international mathematics and science study, and progress in international reading and literacy study. Literature reviewed included refereed and non-refereed journal articles,…

  17. Validation of internal dosimetry protocols based on stochastic method

    International Nuclear Information System (INIS)

    Mendes, Bruno M.; Fonseca, Telma C.F.; Almeida, Iassudara G.; Trindade, Bruno M.; Campos, Tarcisio P.R.

    2015-01-01

    Computational phantoms adapted to Monte Carlo codes have been applied successfully in radiation dosimetry fields. NRI research group has been developing Internal Dosimetry Protocols - IDPs, addressing distinct methodologies, software and computational human-simulators, to perform internal dosimetry, especially for new radiopharmaceuticals. Validation of the IDPs is critical to ensure the reliability of the simulations results. Inter comparisons of data from literature with those produced by our IDPs is a suitable method for validation. The aim of this study was to validate the IDPs following such inter comparison procedure. The Golem phantom has been reconfigured to run on MCNP5. The specific absorbed fractions (SAF) for photon at 30, 100 and 1000 keV energies were simulated based on the IDPs and compared with reference values (RV) published by Zankl and Petoussi-Henss, 1998. The SAF average differences from RV and those obtained in IDP simulations was 2.3 %. The SAF largest differences were found in situations involving low energy photons at 30 keV. The Adrenals and thyroid, i.e. the lowest mass organs, had the highest SAF discrepancies towards RV as 7.2 % and 3.8 %, respectively. The statistic differences of SAF applying our IDPs from reference values were considered acceptable at the 30, 100 and 1000 keV spectra. We believe that the main reason for the discrepancies in IDPs run, found in lower masses organs, was due to our source definition methodology. Improvements of source spatial distribution in the voxels may provide outputs more consistent with reference values for lower masses organs. (author)

  18. Validation of internal dosimetry protocols based on stochastic method

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, Bruno M.; Fonseca, Telma C.F., E-mail: bmm@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Almeida, Iassudara G.; Trindade, Bruno M.; Campos, Tarcisio P.R., E-mail: tprcampos@yahoo.com.br [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2015-07-01

    Computational phantoms adapted to Monte Carlo codes have been applied successfully in radiation dosimetry fields. NRI research group has been developing Internal Dosimetry Protocols - IDPs, addressing distinct methodologies, software and computational human-simulators, to perform internal dosimetry, especially for new radiopharmaceuticals. Validation of the IDPs is critical to ensure the reliability of the simulations results. Inter comparisons of data from literature with those produced by our IDPs is a suitable method for validation. The aim of this study was to validate the IDPs following such inter comparison procedure. The Golem phantom has been reconfigured to run on MCNP5. The specific absorbed fractions (SAF) for photon at 30, 100 and 1000 keV energies were simulated based on the IDPs and compared with reference values (RV) published by Zankl and Petoussi-Henss, 1998. The SAF average differences from RV and those obtained in IDP simulations was 2.3 %. The SAF largest differences were found in situations involving low energy photons at 30 keV. The Adrenals and thyroid, i.e. the lowest mass organs, had the highest SAF discrepancies towards RV as 7.2 % and 3.8 %, respectively. The statistic differences of SAF applying our IDPs from reference values were considered acceptable at the 30, 100 and 1000 keV spectra. We believe that the main reason for the discrepancies in IDPs run, found in lower masses organs, was due to our source definition methodology. Improvements of source spatial distribution in the voxels may provide outputs more consistent with reference values for lower masses organs. (author)

  19. Comparison of vitamins K1, K2 and K3 effects on growth of rat glioma and human glioblastoma multiforme cells in vitro.

    Science.gov (United States)

    Oztopçu, Pinar; Kabadere, Selda; Mercangoz, Ayşe; Uyar, Ruhi

    2004-09-01

    Glioblastoma multiforme is characterized as highly invasive and rapidly growing astrocytomas, and scientists have sought for efficient treatment against malignant gliomas for a long time. Therefore, we compared the respond of rat glioma (C6) and glioblastoma multiforme cells derived from two patients to vitamins K1, K2 and K3. The cells were exposed to 100, 250, 500, 750 and 1000 microM of vitamins K1 and K2, and 1, 10, 25, 50, 75 and 100 microM of vitamin K3 for 24 hours in an incubator atmosphere of 5% CO2, 37 degrees C and 100% humidity. Cell viability was estimated by MTT assay. Vitamin K1 showed no growth effect on all the glioma cells examined. Vitamin K2 did not cause any change in number of C6, however induced growth inhibition in a dose-dependent manner on glioblastoma multiforme. The IC50 values of vitamin K2 were 960 microM and 970 microM for glioblastoma multiforme, respectively. Vitamin K3 had also growth inhibitory effect in a dose-dependent manner on both C6 and glioblastoma multiforme. The IC50 values were 41 microM, 24 microM and 23 microM for vitamin K3, respectively. We concluded that vitamin K3 is more effective than vitamin K2 for inhibition of cancer cell growth, and might have an alternative value as an anticancer drug against glioblastoma multiforme.

  20. K C Deshmukh

    Indian Academy of Sciences (India)

    Home; Journals; Sadhana. K C Deshmukh. Articles written in Sadhana. Volume 30 Issue 4 August 2005 pp 555-563. Thermal deformation in a thin circular plate due to a partially distributed heat supply · N L Khobragade K C Deshmukh · More Details Abstract Fulltext PDF. In this paper, we develop an integral transform to ...

  1. Assessment of the cervical spine denticulate ligament using MRI volumetric sequence: Comparison between 1.5 Tesla and 3.0 Tesla.

    Science.gov (United States)

    Seragioli, Rafael; Simao, Marcelo Novelino; Simao, Gustavo Novelino; Herrero, Carlos Fernando P S; Nogueira-Barbosa, Marcello H

    2018-03-01

    Denticulate ligaments (DLs) are pial extensions on each side of the spinal cord, comprising about 20 to 21 pairs of fibrous structures connecting the dura mater to the spinal cord. These ligaments are significant anatomical landmarks in the surgical approach to intradural structures. To our knowledge, there is no previous study on the detection of DLs using MRI. After IRB approval, we retrospectively evaluated 116 consecutive MRI scans of the cervical spine, using the volumetric sequence 3D COSMIC, 65 and 51 studies with 1.5T and 3.0T respectively. We did not include trauma and tumor cases. Two independent radiologists assessed the detection of cervical spine DLs independently and blinded for each cervical vertebral level. We compared the frequency of detection of these ligaments in 1.5 Tesla and 3.0 Tesla MRI using Fisher exact test considering P<0.05 as significant. We evaluated interobserver agreement with Kappa coefficient. We observed high detection frequency of the cervical spine DLs using both 1.5T (70 to 91%) and 3.0T (68 to 98%). We found no statistically significant difference in the detection frequency of ligaments between the 1.5T and 3.0T MRI in all vertebral levels. Using 3.0T, radiologists identified ligaments better in higher vertebral levels than for lower cervical levels (P=0.0003). Interobserver agreement on the identification of DL was poor both for 1.5T (k=0.3744; CI 95% 0.28-0.46) and 3.0T (k=0.3044; CI 95% 0.18-0.42) MRI. Radiologists identified most of the cervical DLs using volumetric MRI acquisition. Our results suggest 1.5T and 3.0T MRI performed similarly in the detection of DLs. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  2. Internal exposure by natural radiation and decontamination of swimming pool

    International Nuclear Information System (INIS)

    Seki, Hideyuki

    2012-01-01

    This explanation concerns the scientific knowledge and finding of the title subjects for general public to understand their present radiation environment, id est (i.e.), at about 1 year after the Fukushima Daiichi Power Plant Accident (FDPPA). The first described is the world history of radiation exposure, where A-bomb explosion in Hiroshima and Nagasaki, Three Mile Island Power Plant Accident and Chernobyl Accident are told about their teachings and about internal nuclides at FDPPA: the author points out the natural high abundance of K-40 in contrast to the release of I-131, and Cs-137/-134 in the accident. The second is described about the effect of radiations on human cells, where characteristics, measurements, unit and their derived radionuclides of alpha, beta and gamma rays are explained together with their biological influences. Also explained are hydroxy-radical formation by alpha and beta rays in the internal exposure, and comparison of external photons, gamma and more risky ultraviolet rays. Third, the author mentions about man's natural functions to protect radiation hazard. Presented are an easy calculation and a comparison of K-40 and Cs-137 contents (weight and Bq) in the body and in the swimming pool with reference to Chernobyl standards. Internal exposure by natural radionuclides like K-40 and others, is also calculated, which is found equivalent to 0.29 mSv/y based on about 5,630 Bq/60 kg body weight. Finally, explained are the knowledge and practice of decontamination, where various adsorbents like zeolite (molecular sieve), ion exchanger, charcoal and natural zeolites (alumino-silicate) are compared and the last agent, clay easily and economically available, is recommended for decontamination. Clay material is said to adsorb 87% of Cs-137 at as low level as 750 mg/L and the author has an experience to use it successfully for decontamination of the pool. Importantly, the radioactivity of the resultant sludge should not exceed 8,000 Bq/kg. (T.T.)

  3. Blood lactate changes in men during graded workloads at normal atmospheric pressure (100 kPa) and under simulated caisson conditions (400 kPa).

    Science.gov (United States)

    Neubauer, B; Tetzlaff, K; Buslaps, C; Schwarzkopf, J; Bettinghausen, E; Rieckert, H

    1999-05-01

    A hyperbaric environment may influence lactate metabolism due to hyperoxia affecting biochemical pathways. The purpose of our study was to determine the blood lactate levels occurring at high workloads in a sample of professional divers under simulated caisson conditions. The ambient air pressure was equivalent to a diving depth of 30 m of seawater (400 kPa). A total of 23 healthy male subjects performed graded bicycle exercise in a dry hyperbaric chamber up to a maximum of 3.5 W kg(-1) body weight at normal (100 kPa) and elevated ambient air pressure (400 kPa). The blood lactate level and the heart rate were measured. In comparison with control conditions, the heart rate and the peripheral blood lactate level were significantly lower at depth for all workloads. The differences between the normobaric and hyperbaric lactate values may be explained by an overall improvement in lactate metabolism at elevated ambient pressure, especially in the working muscles and the organs responsible for the lactate reduction, i.e., the liver. The reduced heart rate may be an effect of the improved tissue oxygen supply at depth.

  4. Influence of the choice of internal temperatures on the composition of CxHyOzNt plasmas out of thermodynamic equilibrium: Application to CH2 plasma

    International Nuclear Information System (INIS)

    Koalaga, Zacharie

    2002-01-01

    The purpose of this paper is to study the influence of the choice of internal temperatures on the composition of C x H y O z N t plasmas out of thermodynamic equilibrium. The numerical calculation is specially performed for CH 2 plasma in the pressure range 0.1-1 MPa and for the electron temperature range 5000-30 000 K. Precisely, the investigation of this plasma allows one to show that the choice of internal temperatures can have more influence on plasma composition than the choice of the form of the two-temperature Saha and Guldberg-Waage laws. Indeed, for one of the supposed hypotheses, it is observed that the two forms of the two-temperature system used here can give the same equilibrium composition by uncoupling the excitation temperature of the diatomic and the monatomic species. Great attention must then be given to the adopted hypothesis for internal temperature and not only to the form of the two temperature system used. An accurate comparison between the two models requires the measurement of plasma parameters such as the various internal temperatures and the species concentration. Therefore, we have also carried out an analysis of the potential experimental diagnostics of these plasma parameters. Such diagnostics can help to test and validate theoretical models

  5. Comparison of Cleaning Efficacy and Instrumentation Time in Primary Molars: Mtwo Rotary Instruments vs. Hand K-Files.

    Science.gov (United States)

    Ramezanali, Fatemeh; Afkhami, Farzaneh; Soleimani, Ali; Kharrazifard, Mohammad Javad; Rafiee, Farshid

    2015-01-01

    Pulpectomy is the preferred treatment for restorable primary teeth with symptomatic irreversible pulpitis or periradicular lesion. Considering the rather new application of rotary files for pulpectomy of primary teeth, the aim of this study was to compare the cleaning efficacy and instrumentation time of hand K-files and Mtwo rotary system for preparation of human primary molars. This experimental study was conducted on 100 extracted primary maxillary and mandibular intact molars with no resorption. Access cavities were prepared and India ink was injected into the root canal on a vibrator using an insulin syringe. Canals were then divided into 5 groups (n=20): in group I, canals were instrumented using K-files up to #25 for mesial and buccal canals and #30 for palatal and distal canals. In group II, canals were prepared using Mtwo rotary files (15/0.05, 20/0.06 and 25/0.06 for mesial and buccal canals and 15/0.05, 20/0.06, 25/0.06 and finally 30/0.05 for distal and palatal canals). In group III, root canals were only irrigated with saline. Groups IV and V were the positive and negative control groups, respectively. The time required for cleaning and preparation of the canals for each of the specimens in groups I, II and III was recorded. The mean score of cleanliness of Mtwo was not significantly different from K-file group (P>0.05). However the mean instrumentation time in Mtwo group was significantly shorter (Protary files were far more time efficient.

  6. On high temperature internal friction in metallic glasses

    International Nuclear Information System (INIS)

    Zolotukhin, I.V.; Kalinin, Yu.E.; Roshchupkin, A.M.

    1992-01-01

    High temperature background of internal friction in amorphous lanthanum-aluminium alloys was investigated. More rapid growth of internal friction was observed at temperature ∼ 453 K reaching maximal value at 495 K. Crystallization process was accompanied by decrease of internal friction. Increase of mechanical vibration frequency to 1000 Hz leads to rise of internal friction background in the range of room temperatures and to decrease at temperatures above 370 K. Bend was observed on temperature dependence of internal friction at 440 K

  7. Looking beyond general metrics for model comparison - lessons from an international model intercomparison study

    Science.gov (United States)

    de Boer-Euser, Tanja; Bouaziz, Laurène; De Niel, Jan; Brauer, Claudia; Dewals, Benjamin; Drogue, Gilles; Fenicia, Fabrizio; Grelier, Benjamin; Nossent, Jiri; Pereira, Fernando; Savenije, Hubert; Thirel, Guillaume; Willems, Patrick

    2017-01-01

    International collaboration between research institutes and universities is a promising way to reach consensus on hydrological model development. Although model comparison studies are very valuable for international cooperation, they do often not lead to very clear new insights regarding the relevance of the modelled processes. We hypothesise that this is partly caused by model complexity and the comparison methods used, which focus too much on a good overall performance instead of focusing on a variety of specific events. In this study, we use an approach that focuses on the evaluation of specific events and characteristics. Eight international research groups calibrated their hourly model on the Ourthe catchment in Belgium and carried out a validation in time for the Ourthe catchment and a validation in space for nested and neighbouring catchments. The same protocol was followed for each model and an ensemble of best-performing parameter sets was selected. Although the models showed similar performances based on general metrics (i.e. the Nash-Sutcliffe efficiency), clear differences could be observed for specific events. We analysed the hydrographs of these specific events and conducted three types of statistical analyses on the entire time series: cumulative discharges, empirical extreme value distribution of the peak flows and flow duration curves for low flows. The results illustrate the relevance of including a very quick flow reservoir preceding the root zone storage to model peaks during low flows and including a slow reservoir in parallel with the fast reservoir to model the recession for the studied catchments. This intercomparison enhanced the understanding of the hydrological functioning of the catchment, in particular for low flows, and enabled to identify present knowledge gaps for other parts of the hydrograph. Above all, it helped to evaluate each model against a set of alternative models.

  8. An international comparison of reimbursement for DIEAP flap breast reconstruction.

    Science.gov (United States)

    Reid, A W N; Szpalski, C; Sheppard, N N; Morrison, C M; Blondeel, P N

    2015-11-01

    The deep inferior epigastric artery perforator (DIEAP) flap is currently considered the gold standard for autologous breast reconstruction. With the current economic climate and health cutbacks, we decided to survey reimbursement for DIEAP flaps performed at the main international centres in order to assess whether they are funded consistently. Data were collected confidentially from the main international centres by an anonymous questionnaire. Our results illustrate the wide disparity in international DIEAP flap breast reconstruction reimbursement: a unilateral DIEAP flap performed in New York, USA, attracts €20,759, whereas the same operation in Madrid, Spain, will only be reimbursed for €300. Only 35.7% of the surgeons can set up their own fee. Moreover, 85.7% of the participants estimated that the current fees are insufficient, and most of them feel that we are evolving towards an even lower reimbursement rate. In 55.8% of the countries represented, there is no DIEAP-specific coding; in comparison, 74.4% of the represented countries have a specific coding for transverse rectus abdominis (TRAM) flaps. Finally, despite the fact that DIEAP flaps have become the gold standard for breast reconstruction, they comprise only a small percentage of all the total number of breast reconstruction procedures performed (7-15%), with the only exception being Belgium (40%). Our results demonstrate that DIEAP flap breast reconstruction is inconsistently funded. Unfortunately though, it appears that the current reimbursement offered by many countries may dissuade institutions and surgeons from offering this procedure. However, substantial evidence exists supporting the cost-effectiveness of perforator flaps for breast reconstruction, and, in our opinion, the long-term clinical benefits for our patients are so important that this investment of time and money is absolutely essential. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons

  9. Internal deformation in layered Zechstein-III K-Mg salts. Structures formed by complex deformation and high contrasts in viscosity observed in drill cores.

    Science.gov (United States)

    Raith, Alexander; Urai, Janos L.

    2016-04-01

    During the evaporation of a massive salt body, alternations of interrupted and full evaporation sequences can form a complex layering of different lithologies. Viscosity contrasts of up to five orders of magnitude between these different lithologies are possible in this environment. During the late stage of an evaporation cycle potassium and magnesium (K-Mg) salts are precipitated. These K-Mg salts are of economic interest but also a known drilling hazard due to their very low viscosity. How up to 200m thick layers of these evaporites affect salt deformation at different scales is not well known. A better understanding of salt tectonics with extreme mechanical stratification is needed for better exploration and production of potassium-magnesium salts and to predict the internal structure of potential nuclear waste repositories in salt. To gain a better understanding of the internal deformation of these layers we analyzed K-Mg salt rich drill cores out of the Zechstein III-1b subunit from the Veendam Pillow 10 km southeast of Groningen, near the city Veendam in the NE Netherlands. The study area has a complex geological history with multiple tectonic phases of extension and compression forming internal deformation in the pillow but also conserving most of the original layering. Beside halite the most common minerals in the ZIII-1b are carnallite, kieserite, anhydrite and bischofite alternating in thin layers of simple composition. Seismic interpretation revealed that the internal structure of the Veendam Pillow shows areas, in which the K-Mg salt rich ZIII 1b layer is much thicker than elsewhere, as a result of salt deformation. The internal structure of the ZIII-1b on the other hand, remains unknown. The core analysis shows a strong strain concentration in the weaker Bischofite (MgCl2*6H20) and Carnallite (KMgCl3*6H20) rich layers producing tectonic breccias and highly strained layers completely overprinting the original layering. Layers formed by alternating beds

  10. International practices in the provision of teratology information: a survey of international teratogen information programmes and comparisons with the North American model.

    Science.gov (United States)

    Hancock, Rebecca L; Ungar, Wendy J; Einarson, Adrienne; Koren, Gideon

    2010-10-01

    Teratology Information Services (TIS) provide health care professionals and the public with information regarding the safety and/or risk of exposures during pregnancy and lactation, mainly via telephone consultations. An international comparison of clinical practices at TIS has never been conducted. The survey objective was to compare international TIS to North American TIS, with an aim to identify strengths and challenges that can lead to service improvement. Twenty-two international TIS were approached for participation during an international conference. TIS were surveyed on information in six categories: services, staffing, operations, data collection, knowledge transfer activities and additional information. Data were summarized using descriptive statistics. Statistical tests were conducted using SPSS®. Sixteen TIS from 12 countries participated. Survey results were compared with previously reported results from a similar survey of North American TIS (16 US, two Canadian). TIS exist in a variety of departments and settings, but most commonly are in university hospitals. Pregnant women were the most commonly counselled group worldwide. International TIS spent significantly more time fielding inquiries regarding medications, while North American TIS had a wider variety of inquiry categories. All TIS could improve budget tracking. Overall, service practices and goals were similar, although international TIS conducted more follow-up with service users than North American TIS. This report offers TIS the first ever opportunity to compare practices. Increased dialogue between TIS encourages sharing of best practices and improves the ability of these important public health programmes to support women and health care providers. © 2010 Blackwell Publishing Ltd.

  11. Factorial and reduced K-means reconsidered

    NARCIS (Netherlands)

    Timmerman, Marieke E.; Ceulemans, Eva; Kiers, Henk A. L.; Vichi, Maurizio

    2010-01-01

    Factorial K-means analysis (FKM) and Reduced K-means analysis (RKM) are clustering methods that aim at simultaneously achieving a clustering of the objects and a dimension reduction of the variables. Because a comprehensive comparison between FKM and RKM is lacking in the literature so far, a

  12. Internal Revolutions: Auto-Ethnography as a Method for Faculty Who Prepare K-12 Educators and Leaders at Hispanic Serving Institutions

    Science.gov (United States)

    Aguilar, Israel

    2017-01-01

    This article reinforces the use of research for faculty who prepare K-12 educators and leaders for social justice. The author conceptualizes auto-ethnography as a form of professional development and maintains that faculty must first experience an internal revolution before they can expect to model it, especially in a Hispanic Serving Institution…

  13. Aggregation Methods in International Comparisons

    NARCIS (Netherlands)

    B.M. Balk (Bert)

    2001-01-01

    textabstractThis paper reviews the progress that has been made over the past decade in understanding the nature of the various multilateral in- ternational comparison methods. Fifteen methods are discussed and subjected to a system of ten tests. In addition, attention is paid to recently developed

  14. Application of magnetic carriers for whole DNA isolation and detection of probiotic Lactobacillus gasseri K7 strain in complex samples

    Czech Academy of Sciences Publication Activity Database

    Trachtová, Š.; Obermajer, T.; Španová, A.; Bogovič, M. B.; Rogelj, I.; Horák, Daniel; Rittich, B.

    -, č. 4 (2009), A27-A28 ISSN 1727-7906. [International Congress of the SOMED /32./ - Probiotics 2009. 29.10.2009-30.10.2009, St. Petersburg] R&D Projects: GA MŠk 2B06053 Institutional research plan: CEZ:AV0Z40500505 Keywords : magnetic * DNA * microsphers Subject RIV: EE - Microbiology, Virology

  15. International comparison of energy price using a purchasing power parity

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Dong Hun; Jo, Sung Han [Korea Energy Economics Institute, Euiwang (Korea)

    1999-05-01

    The price control of government results in price distortion as well as lowering efficiency of energy market and distortion of allocating resources. Consequently, such a price policy leads to energy overconsumption and has negative influences on other policies trying to reduce environmental burden resulted from energy consumption. When the energy price does not reflect the market price properly, it results in inefficiency of energy industry and it makes very difficult to supply investment funds. Therefore, the government is planning to implement liberalization of energy price step by step. The purpose of this study is to provide basic materials for establishing a reasonable energy price policy through the international comparison among OECD countries on major products price focusing on petroleum products. To overcome problems of exchange rate, a purchasing power indicator from OECD was used for comparative analysis with OECD countries. 11 refs. 1 fig., 23 tabs.

  16. Turismifirmade 2000. a. TOP 30

    Index Scriptorium Estoniae

    2001-01-01

    Turismiettevõtete üldandmed: turismiettevõtete finantsnäitajad; käibe TOP 30; käibe kasvu TOP 10; kasumi TOP 20; kasumi kasvu TOP 10; kasumi languse TOP; rentaabluse TOP 10; varade tootlikkuse TOP 10

  17. Upgrade of a 30 kV/10 mA anode power supply for triode type gyrotron

    Energy Technology Data Exchange (ETDEWEB)

    Siravo, Ugo, E-mail: ugo.siravo@epfl.ch; Alberti, Stefano; Dubray, Jérémie; Fasel, Damien; Hogge, Jean-Philippe; Marlétaz, Blaise; Marmillod, Philippe; Perez, Albert; Silva, Miguel

    2015-10-15

    Highlights: • Triode type gyrotron is fed by 3 power supplies: the main, an anode PS(APS) and a heater. • This paper presents the upgrade of 3APS, supplied in 1999, that never fulfilled the specs. • The new working principle is very efficient, easy to implement, for a minimal cost. • Upgraded APS provides extended modulation capabilities, no overshoot and lowerripple. • This upgrade will allow exploring new operation regimes for the 3 TCV X3 gyrotrons. - The RF power of a gyrotron with a triode type magnetron-injection-gun (MIG) can be directly controlled via the voltage applied between its anode and its cathode. Hence, the performance of this type of gyrotron relies directly on the possibilities offered by the power supply controlling the anode to cathode voltage. For a system of gyrotrons connected to the same main high-voltage power supply, with a triode MIG one has the additional advantage of independently controlling each individual gyrotron. This paper presents the modifications brought to the three existing 30 kV/10 mA anode power supplies connected to the 500 kW/118 GHz/2s X3 gyrotrons operated on the TCV Tokamak. The new working principle based on phase-shift modulation (PSM) is described in detail. Experimental results obtained on dummy load are compared to simulations performed during the design phase. With respect to the initial working principle, the modulation frequency capability has been increased by a factor 10 reaching more than 5 kHz, whereas the output voltage ripple as well as the overshoot/undershoot have been significantly reduced.

  18. An international comparison of nuclear plant training programs

    International Nuclear Information System (INIS)

    Mason, J.H.

    1993-01-01

    In 1990, I visited four utility companies that own and operate pressurized water reactor (PWR) plants in different countries. The purpose of my visits and associated research was to compare nuclear power plant operator and technician training programs. The companies were: Duke Power Company (DUKE) in the United States, Electricite de France (EDF) in France, Kansai Electric Power Company (KEPCO) in Japan, and RWE Energie AG (RWE) in Germany. The purpose of this paper is to highlight selected aspects of the comparison. First, comparisons of the four subject utilities and four typical nuclear power stations operated by each company, McGuire, Paluel, Ohi, and Biblis, are provided. Then comparisons of new employee demographics and training program specific content are provided. Finally, some general observations are drawn from the comparisons. The comparisons are based on information obtained from documents, interviews, and visits to stations and training centers. However, some interpretation of the information was necessary in order to enable a comparison. For example, categorization of training modules requires judgement, interpretation, and translation. In all cases, the information is intended to be representative or typical, rather than statistically precise

  19. Comparison between two pencil-type ionization chambers with sensitive volume length of 30 cm

    International Nuclear Information System (INIS)

    Castro, Maysa C. de; Xavier, Marcos; Silva, Natalia F.; Caldas, Linda V.E.

    2016-01-01

    Computed tomography (CT) for imaging procedures has been growing due to advances in the equipment technology, providing a higher dose to the patient, in relation to other diagnostic radiology tests, resulting in a concern for the patients. The dosimetry in CT is carried out with a pencil-type ionization chamber with sensitive volume length of 10 cm. Studies have shown the underestimation of the dose values. In this work two ionization chambers with the sensitive volume length of 30 cm were developed. They were submitted to the main characterization tests; the results showed to be within the international recommended limits. (author)

  20. Bilateral key comparison SIM.T-K6.5 on humidity standards in the dew/frost-point temperature range from -30 °C to +20 °C

    Science.gov (United States)

    Meyer, C.; Solano, A.

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica) between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and LACOMET. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Comparison of fracture toughness (K{sub IC}) and strain energy release rate (G) of selected nuclear graphites

    Energy Technology Data Exchange (ETDEWEB)

    Chi, Se-Hwan, E-mail: shchi@kaeri.re.kr

    2016-08-01

    The fracture behaviors of six nuclear graphite grades for a high-temperature gas-cooled reactor (HTGR), which differed in coke particle size and forming method, were characterized based on the ASTM standard graphite fracture toughness test method (ASTM D 7779-11) at room temperature. The G appeared to show good correlation with the fracture surface roughness and the G-Δa curves appeared to describe the fracture process well from crack initiation to failure. Comparison of the local (K{sub IC}) and gross (G{sub IC}, G-Δa) fracture parameters showed that the resistance to crack initiation and propagation was higher in the extruded or vibration molded medium particle size grades (PCEA, NBG-17, NBG-18: EVM group) than in the iso-molded fine particle size grades (IG-110, IG-430, NBG-25: IMF group). The ASTM may need to provide a guideline for G-Δa curve analysis. The K{sub IC} appeared to increase with specimen thickness (size).

  2. The National Strategy of Ecological Transition towards Sustainable Development - International comparisons

    International Nuclear Information System (INIS)

    Kleiber, Florence; Vey, Frederic; Moreau, Sylvain; Bottin, Anne; Baudu-Baret, Claude

    2017-05-01

    The National Strategy of Ecological Transition towards Sustainable Development (SNTEDD) 2015-2020 follows on from the 2010-2013 National Strategy for Sustainable Development. Adopted at the Council of Ministers meeting of 4 February 2015, the SNTEDD identifies four major ecological challenges and nine strategic areas of action. The SNTEDD is monitored by 72 indicators developed via a collaborative process of selection implemented by a special commission of the National Council for Ecological Transition (CNTE) responsible for the indicators. This 'indicators' commission has sought to obtain a perspective on outcomes by means of international comparisons. This study presents initial elements of an analysis of France's situation compared with that of other countries (mostly EU or OECD members) with regard to each of the challenges and areas of action identified in the SNTEDD

  3. BIPM direct on-site Josephson voltage standard comparisons: 20 years of results

    International Nuclear Information System (INIS)

    Solve, Stephane; Stock, Michael

    2012-01-01

    The discovery of the Josephson effect has for the first time given national metrology institutes (NMIs) the possibility of maintaining voltage references which are stable in time. In addition, the introduction in 1990 of a conventional value for the Josephson constant, K J-90 , has greatly improved world-wide consistency among representations of the volt. For 20 years, the Bureau International des Poids et Mesures (BIPM) has conducted an ongoing, direct, on-site key comparison of Josephson voltage standards among NMIs under the denominations BIPM.EM-K10.a (1 V) and BIPM.EM-K10.b (10 V) in the framework of the mutual recognition arrangement (CIPM MRA). The results of 41 comparisons illustrate the consistency among primary voltage standards and have demonstrated that a relative total uncertainty of a few parts in 10 10 is achievable if a few precautions are taken with regard to the measurement set-up. Of particular importance are the grounding, efficient filters and high insulation resistance of the measurement leads, and clean microwave distribution along the propagation line to the Josephson array. This paper reviews the comparison scheme and technical issues that need to be taken into account to achieve a relative uncertainty at the level of a few parts in 10 10 or even a few parts in 10 11 in the best cases. (paper)

  4. Round busbar concept for 30 nH, 1.7 kV, 10 kA IGBT non-destructive short-circuit tester

    DEFF Research Database (Denmark)

    Smirnova, Liudmila; Pyrhönen, Juha; Iannuzzo, Francesco

    2014-01-01

    Design of a Non-Destructive Test (NDT) set-up for short-circuit tests of 1.7 kV, 1 kA IGBT modules is discussed in this paper. The test set-up allows achieving short-circuit current up to 10 kA. The important objective during the design of the test set-up is to minimize the parasitic inductance...

  5. Search Results | Page 30 | IDRC - International Development ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Results 291 - 300 of 8491 ... Reduction of Gender and Institutional Violence against Mesoamerican Migrant Women. Six out of ten Central American women on their way through Mexico are victims of sexual violence, according to reports from Amnesty International. Project.

  6. An International Standard Equation of State for Difluoromethane (R-32) for Temperatures from the Triple Point at 136.34 K to 435 K and Pressures up to 70 MPa

    International Nuclear Information System (INIS)

    Tillner-Roth, R.; Yokozeki, A.

    1997-01-01

    A fundamental equation of state for the Helmholtz free energy of R-32 (difluoromethane) is presented which is valid from the triple point at 136.34 K to 435 K and pressures up to 70 MPa. It is based on accurate measurements of pressure-density-temperature (p,ρ,T), speed of sound, heat capacity, and vapor pressure currently available. New values for the isobaric heat capacity c p circ of the ideal gas calculated from spectroscopic data taking into account also first order anharmonicity corrections are presented. The Helmholtz free energy equation of state has 19 coefficients and represents all selected experimental data within their estimated accuracy with the exception for heat capacities and speed of sound in the region close to the critical point. Typical uncertainties are ±0.05% for density, ±0.02% for the vapor pressure and ±0.5%endash 1% for the heat capacity. This equation of state has been compared to equations developed by other research groups by Annex 18 of the International Energy Agency and has been selected as an international standard formulation for the thermodynamic properties of R-32 by this group. copyright 1997 American Institute of Physics and American Chemical Society

  7. Eighth meeting of the International Working Group on Gas-Cooled Reactors, Vienna, 30 January - 1 February 1989. Summary report. Part 1

    International Nuclear Information System (INIS)

    1989-12-01

    The Eighth Meeting of the IAEA International Working Group on Gas-Cooled Reactors was held in Vienna, Austria, from 30 January - 1 February, 1989. The Summary Report (Part I) contains the Minutes of the Meeting

  8. The Planck Constant, the International System of Units, and the 2012 North American Watt Balance Absolute Gravity Comparison

    Science.gov (United States)

    Newell, D. B.

    2012-12-01

    As outlined in Resolution 1 of the 24th Meeting of the General Conference on Weights and Measures (CGPM) on the future revision of the International System of Units (SI) [1], the current four SI base units the kilogram, the ampere, the kelvin and the mole, will be redefined in terms of invariants of nature. The new definitions will be based on fixed numerical values of the Planck constant (h), the elementary charge (e), the Boltzmann constant (k), and the Avogadro constant (NA), respectively. While significant progress has been made towards providing the necessary experimental results for the redefinition, some disagreement among the relevant data remain. Among the set of discrepant data towards the redefinition of the SI are the determinations of the Planck constant from the National Institute of Standards and Technology (NIST) watt balance [2] and the recent result from the National Research Council Canada (NRC) watt balance [3], with the discrepancy of roughly 2.5 parts in 107 being significantly outside the reported uncertainties. Of major concern is that the watt balance experiment is seen as a key component of a mise en pratique for the new kilogram definition, once such a redefinition takes place. The basic operational principle of a watt balance relates the Planck constant to mass, length, and time through h = mgvC, where m is the mass of an artifact mass standard, g is the local acceleration of gravity, v is a velocity, and C is a combination of frequencies and scalar constants. With the total uncertainty goal for the watt balance on the order of a few parts in 108, g needs to be determined at the location of the mass standard to parts in 109 such that its uncertainty is negligible in the final watt balance result. NIST and NRC have formed a collaborative effort to reconcile the relevant discrepant data and provide further progress towards preparing and testing a mise en pratique for the new kilogram definition. As an initial step, direct comparisons of

  9. Regional correlations of V s30 and velocities averaged over depths less than and greater than 30 meters

    Science.gov (United States)

    Boore, D.M.; Thompson, E.M.; Cadet, H.

    2011-01-01

    Using velocity profiles from sites in Japan, California, Turkey, and Europe, we find that the time-averaged shear-wave velocity to 30 m (V S30), used as a proxy for site amplification in recent ground-motion prediction equations (GMPEs) and building codes, is strongly correlated with average velocities to depths less than 30 m (V Sz, with z being the averaging depth). The correlations for sites in Japan (corresponding to the KiK-net network) show that V S30 is systematically larger for a given V Sz than for profiles from the other regions. The difference largely results from the placement of the KiK-net station locations on rock and rocklike sites, whereas stations in the other regions are generally placed in urban areas underlain by sediments. Using the KiK-net velocity profiles, we provide equations relating V S30 to V Sz for z ranging from 5 to 29 m in 1-m increments. These equations (and those for California velocity profiles given in Boore, 2004b) can be used to estimate V S30 from V Sz for sites in which velocity profiles do not extend to 30 m. The scatter of the residuals decreases with depth, but, even for an averaging depth of 5 m, a variation in log V S30 of 1 standard deviation maps into less than a 20% uncertainty in ground motions given by recent GMPEs at short periods. The sensitivity of the ground motions to V S30 uncertainty is considerably larger at long periods (but is less than a factor of 1.2 for averaging depths greater than about 20 m). We also find that V S30 is correlated with V Sz for z as great as 400 m for sites of the KiK-net network, providing some justification for using V S30 as a site-response variable for predicting ground motions at periods for which the wavelengths far exceed 30 m.

  10. An international comparison of regulatory organizations and licensing procedures for new nuclear power plants

    International Nuclear Information System (INIS)

    Bredimas, Alexandre; Nuttall, William J.

    2008-01-01

    This paper considers measures needed to license new nuclear power plants efficiently. We base our analysis on international standards and a comparison of the national regulatory and licensing framework in seven countries (Canada, France, Germany, Japan, Switzerland, the UK and the USA). We split the review into the organization of regulatory responsibilities and the licensing process. We propose a set of considerations that should be incorporated into national solutions. While conscious of the different cultural fundamentals of each region, we hope this paper will help fuel an emerging debate on this highly topical issue

  11. Underground cables as an alternative to overhead lines. A comparison of economic and technical aspects of voltages over 22 kV

    Energy Technology Data Exchange (ETDEWEB)

    Trohjell, J.E.; Vognild, I.H.

    1994-07-11

    The report presents technical and economical aspects of underground cables compared to overhead lines in Norway in high voltage transmission systems above 22 kV. The economical comparison between the two options includes capital costs of installation (investment costs), maintenance costs and costs of electrical losses. The main technical issues discussed are reliability and flexibility. 35 refs., 23 figs., 29 tabs.

  12. Numerical assessment of factors affecting nonlinear internal waves in the South China Sea

    Science.gov (United States)

    Li, Qiang

    2014-02-01

    Nonlinear internal waves in the South China Sea exhibit diverse characteristics, which are associated with the complex conditions in Luzon Strait, such as the double ridge topography, the Earth’s rotation, variations in stratification and the background current induced by the Kuroshio. These effects are individually assessed using the MITgcm. The performance of the model is first validated through comparison with field observations. Because of in-phased ray interaction, the western ridge in Luzon Strait intensifies the semidiurnal internal tides generated from the eastern ridge, thus reinforcing the formation of nonlinear internal waves. However, the ray interaction for K1 forcing becomes anti-phased so that the K1 internal tide generation is reduced by the western ridge. Not only does the rotational dispersion suppress internal tide generation, it also inhibits nonlinear steepening and consequent internal solitary wave formation. As a joint effect, the double ridges and the rotational dispersion result in a paradoxical phenomenon: diurnal barotropic tidal forcing is dominant in Luzon Strait, but semidiurnal internal tides prevail in the deep basin of the South China Sea. The seasonal variation of the Kuroshio is consistent with the seasonal appearance of nonlinear internal waves in the South China Sea. The model results show that the westward inflow due to the Kuroshio intrusion reduces the amplitude of internal tides in the South China Sea, causing the weakening or absence of internal solitary waves. Winter stratification cannot account for the significant reduction of nonlinear internal waves, because the amplitude growth of internal tides due to increased thermocline tilting counteracts the reduced nonlinearity caused by thermocline deepening.

  13. Sequential combination of k-t principle component analysis (PCA) and partial parallel imaging: k-t PCA GROWL.

    Science.gov (United States)

    Qi, Haikun; Huang, Feng; Zhou, Hongmei; Chen, Huijun

    2017-03-01

    k-t principle component analysis (k-t PCA) is a distinguished method for high spatiotemporal resolution dynamic MRI. To further improve the accuracy of k-t PCA, a combination with partial parallel imaging (PPI), k-t PCA/SENSE, has been tested. However, k-t PCA/SENSE suffers from long reconstruction time and limited improvement. This study aims to improve the combination of k-t PCA and PPI on both reconstruction speed and accuracy. A sequential combination scheme called k-t PCA GROWL (GRAPPA operator for wider readout line) was proposed. The GRAPPA operator was performed before k-t PCA to extend each readout line into a wider band, which improved the condition of the encoding matrix in the following k-t PCA reconstruction. k-t PCA GROWL was tested and compared with k-t PCA and k-t PCA/SENSE on cardiac imaging. k-t PCA GROWL consistently resulted in better image quality compared with k-t PCA/SENSE at high acceleration factors for both retrospectively and prospectively undersampled cardiac imaging, with a much lower computation cost. The improvement in image quality became greater with the increase of acceleration factor. By sequentially combining the GRAPPA operator and k-t PCA, the proposed k-t PCA GROWL method outperformed k-t PCA/SENSE in both reconstruction speed and accuracy, suggesting that k-t PCA GROWL is a better combination scheme than k-t PCA/SENSE. Magn Reson Med 77:1058-1067, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  14. Comparison of x-ray computed tomography, through-transmission ultrasound, and low-kV x-ray imaging for characterizing green-state ceramics

    International Nuclear Information System (INIS)

    Roberts, R.A.; Ellingson, W.A.; Vannier, M.W.

    1985-06-01

    Green-state MgAl 2 O 4 compact disk specimens have been studied by x-ray computed tomography (CT), through-transmission pulsed ultrasound, and low-kV x-ray imaging to compare the abilities of these nondestructive evaluation (NDE) methods to detect flaws and density variations. X-ray computed tomographic images were obtained from a 125-kV (peak) imaging system with a 512 x 512 matrix and a pixel size of 100 μm. A 3- to 10- MHz focused-beam ultrasonic transducer was used, together with special immersion techniques, to obtain topographical maps of acoustic attenuation and phase velocity; a 30 x 30 matrix was used in the ultrasonic scans. A 35-kV x-ray system with high-resolution type RR film was used to obtain conventional radiographs. Large-scale nonuniform density gradients were detected with CT and ultrasonics in supposedly uniform ceramic disks. In addition, inclusions in the green-state samples were detected by all three methods, with each method providing certain advantages. The influence of grain structure and other ceramic powder characteristics will be examined in the future. 5 refs., 9 figs

  15. A Comparison of Clinical Parameters and Outcomes over 1 Year in Home Hemodialysis Patients Using 2008K@home or NxStage System One.

    Science.gov (United States)

    Brunelli, Steven M; Wilson, Steven M; Ficociello, Linda H; Mullon, Claudy; Diaz-Buxo, Jose A

    2016-01-01

    The prevalence of home hemodialysis (HHD) in the United States is growing, driven in part by improvements in dialysis machines for home use. We assessed clinical parameters and outcomes in HHD patients using either Fresenius 2008K@home or NxStage System One over 1 year. Patients were 18 years or older and received HHD for ≥30 days between January 1, 2009, and June 30, 2010. A propensity score match was used to control for differences in baseline characteristics, and 2008K@home patients were stratified by frequency of use. Data for outcome measures were analyzed using generalized linear mixed models. Treatment frequency was lower for 2008K@home groups than System One. Mean standardized Kt/V (stdKt/V) was 2.75 for 2008K@home ≥3.5x/week users and 1.99 for System One users (p < 0.001). Erythropoiesis-stimulating agent use tended to be lower for patients using System One. There were no statistically significant differences across groups in serum albumin, calcium, phosphorus, hemoglobin, or parathyroid hormone levels, normalized protein catabolic rate, body mass index, number of hospitalizations, or hospitalized days. Clinical parameters and outcomes for HHD patients using 2008K@home and System One were largely equivalent, although 2008K@home use was associated with higher stdKt/V. Further studies will be required to establish whether these differences in stdKt/V relate to differences in technology, treatment schedule, or a combination thereof.

  16. Search for a PHI' vector meson in diffractive photoproduction of K+K-π+π-

    International Nuclear Information System (INIS)

    Atkinson, M.; Davenport, M.; Flower, P.; Hutton, J.S.; Kumar, B.R.; Morris, J.A.G.; Morris, J.V.; Patrick, G.N.; Sharp, P.H.; Bussey, P.J.; Dainton, J.B.; Paterson, C.; Raine, C.; Skillicorn, I.O.; Smith, K.M.; Brodbeck, T.J.; Clegg, A.B.; Flynn, P.J.; Henderson, R.C.W.; Newton, D.; Axon, T.J.; Barberis, D.; Dickinson, B.; Donnachie, A.; Ellison, R.J.; Hughes-Jones, R.E.; Ibbotson, M.; Lafferty, G.D.; Lane, J.B.; Mercer, D.; Thompson, R.J.; Waite, A.P.; Worsell, M.F.; Levy, J.M.; Laberrigue, J.; La Vaissiere, C. de; Yiou, T.P.; Brookes, G.R.; Bunn, J.J.; Galbraith, W.; McClatchey, R.H.

    1986-01-01

    A study of photoproduction of K + K - π + π - shows a broad threshold enhancement, about 30% of which is due to Ksup(*)Kπ production. This Ksup(*)Kπ component shows no dynamical features indicative of the existence of a PHI' vector meson in this channel. (orig.)

  17. Pretranslational regulation of Na-K-ATPase in cultured canine kidney cells by low K

    Energy Technology Data Exchange (ETDEWEB)

    Bowen, J.W.; McDonough, A.

    1987-02-01

    Long-term upregulation of the sodium pump (Na-K-adenosine triphosphatase (Na-K-ATPase)) entails an increase in the number of enzyme molecules. The authors incubated Madin-Darby canine kidney (MDCK) cells in low K medium and studied the time course and magnitude of change in the relative abundance of the two Na-K-ATPase subunits ( and US ), in the synthesis rate of the subunits, and in the relative abundance of - and US -mRNA. When cells were incubated in medium containing 0.25 mM K , intracellular Na increased. The relative abundance of Na-K-ATPase subunits, measured with ( SVI)-labelled immunoblots of cell homogenates, increases such that after 24 h was 1.71 +/- 0.33 and US was 1.67 +/- 0.22 times control. After 8 h of K depletion, -synthesis rate, measured by immunoprecipitation of pulse-labelled cells, increased to 2.30 +/- 0.50 and beta increased to 2.07 +/- 0.42 times control. The - and US -subunit mRNA abundance, measured by hybridizing - and US -cDNA probes to total RNA, increased within 30 min to 1.93 +/- 0.24 and 2.29 +/- 0.64 times control, respectively. They conclude that regulatory adjustments of Na-K-ATPase abundance involve an increase in translation after a rapid and coordinate increase in the concentrations of - and US -subunit mRNA.

  18. Comparison of iodine K-edge subtraction and fluorescence subtraction imaging in an animal system

    International Nuclear Information System (INIS)

    Zhang, H.; Zhu, Y.; Bewer, B.; Zhang, L.; Korbas, M.; Pickering, I.J.; George, G.N.; Gupta, M.; Chapman, D.

    2008-01-01

    K-Edge Subtraction (KES) utilizes the discontinuity in the X-ray absorption across the absorption edge of the selected contrast element and creates an image of the projected density of the contrast element from two images acquired just above and below the K-edge of the contrast element. KES has proved to be powerful in coronary angiography, micro-angiography, bronchography, and lymphatic imaging. X-ray fluorescence imaging is a successful technique for the detection of dilute quantities of elements in specimens. However, its application at high X-ray energies (e.g. at the iodine K-edge) is complicated by significant Compton background, which may enter the energy window set for the contrast material's fluorescent X-rays. Inspired by KES, Fluorescence Subtraction Imaging (FSI) is a technique for high-energy (>20 keV) fluorescence imaging using two different incident beam energies just above and below the absorption edge of a contrast element (e.g. iodine). The below-edge image can be assumed as a 'background' image, which includes Compton scatter and fluorescence from other elements. The above-edge image will contain nearly identical spectral content as the below-edge image but will contain the additional fluorescence of the contrast element. This imaging method is especially promising with thick objects with dilute contrast materials, significant Compton background, and/or competing fluorescence lines from other materials. A quality factor is developed to facilitate the comparison. The theoretical value of the quality factor sets the upper limit that an imaging method can achieve when the noise is Poisson limited. The measured value of this factor makes two or more imaging methods comparable. Using the Hard X-ray Micro-Analysis (HXMA) beamline at the Canadian Light Source (CLS), the techniques of FSI and KES were critically compared, with reference to radiation dose, image acquisition time, resolution, signal-to-noise ratios, and quality factor

  19. Internal conversion coefficients of M4 isomeric transitions in /sup 125/ /sup 127/ /sup 129/Te decay

    Energy Technology Data Exchange (ETDEWEB)

    Soni, S K; Kumar, A; Gupta, S L; Pancholi, S C [Delhi Univ. (India). Dept. of Physics and Astrophysics

    1977-01-01

    The internal conversion coefficients have been measured using a high resolution low energy Ge(Li) detector for the following M4 transitions: /sup 125/Te: 109.27 keV transition ..cap alpha..sub(T) = 357 +- 11; RG method, /sup 127/Te: 88,26 keV transition ..cap alpha..sub(K) = 484 +- 23; XPG method, /sup 129/Te: 105.50 keV transition ..cap alpha..sub(K) = 213 +- 10; XPG method. It is observed that these values are lower by 2.5-3.6% as compared with Hager and Seltzer's calculations. A comparison between experimental and theoretical ..cap alpha..sub(K) and ..cap alpha..sub(T) values for eleven M4 transitions shows that the experimental values are systematically lower.

  20. (p, ρ, T) Properties for n-butane in the temperature range from 280 K to 380 K at pressures up to 200 MPa

    International Nuclear Information System (INIS)

    Miyamoto, H.; Uematsu, M.

    2007-01-01

    The (p, ρ, T) properties for n-butane in the compressed liquid phase were measured by means of a metal-bellows variable volumometer in the temperature range from 280 K to 380 K at pressures up to 200 MPa. The mole fraction purity of the n-butane used in the measurements was 0.9997. The expanded uncertainties (k = 2) in temperature, pressure, and density measurements have been estimated to be less than ±3 mK; 1.4 kPa (p ≤ 7 MPa), 0.06% (7 MPa 150 MPa); and 0.09%, respectively. In the region above100 MPa at T = 280 K and T = 440 K, the uncertainty in density measurements increases from 0.09% to 0.13% and 0.22%, respectively. Eight (p, ρ, T) measurements at the same temperatures and pressures as the literature values have been conducted for comparisons. In addition, comparisons of the available equations of state with the present measurements are reported

  1. Rockets and feathers revisited: an international comparison on European gasoline markets

    International Nuclear Information System (INIS)

    Galeotti, Marzio; Lanza, Alessandro; Manera, Matteo

    2003-01-01

    This paper re-examines the issue of asymmetries in the transmission of shocks to crude oil prices onto the retail price of gasoline. The distinguishing features are: (i) use of updated and comparable data to carry out an international comparison of gasoline markets; (ii) two-stage modeling of the transmission mechanism, in order to assess possible asymmetries at either the refinery stage, the distribution stage or both; (iii) use of asymmetric error correction models to distinguish between short-run and long-run asymmetries; (iv) explicit, possibly asymmetric, role of the exchange rate; (v) bootstrapping of F-tests of asymmetries, in order to overcome the low-power problem of conventional testing procedures. In contrast to several previous findings, the results generally point to widespread differences in both adjustment speeds and short-run responses when input prices rise or fall. (Author)

  2. International handling of fissionable material

    International Nuclear Information System (INIS)

    1975-01-01

    The opinion of the ministry for foreign affairs on international handling of fissionable materials is given. As an introduction a survey is given of the possibilities to produce nuclear weapons from materials used in or produced by power reactors. Principles for international control of fissionable materials are given. International agreements against proliferation of nuclear weapons are surveyed and methods to improve them are proposed. (K.K.)

  3. A study of non-charge-exchange anti K0π- production in the reaction K-p→anti K0π-p at 4.2 GeV/c

    International Nuclear Information System (INIS)

    Engelen, J.J.; Holwerda, M.J.; Kittel, E.W.; Tieke, H.G.J.M.; Vergeest, J.S.M.; Grossmann, P.; Lyons, L.; McDowell, L.

    1978-01-01

    The anti K 0 π - system produced in the reaction K - p→anti K 0 π - p at 4.2 GeV/c is studied using high-statistics bubble-chamber data. The spin-parity structure is analyzed as a function of the anti K 0 π - mass up to 1.52 GeV. Production of K*(890) and K*(1420) is observed in helicity-0 and helicity-1 states. Contributions of natural and unnatural parity exchange are present. Considerable S-wave production is observed over the whole mass region considered. The t' dependence of the K*(890) and K*(1420) amplitudes is also studied. A comparison of the results on K*(890) production with the results of an analysis of charge-exchange K*(890) production, allows the separation of I=0 and I=1 exchange amplitudes. Some qualitative remarks are made concerning K*(1420) production. (Auth.)

  4. Internal friction in martensitic carbon steels

    International Nuclear Information System (INIS)

    Hoyos, J.J.; Ghilarducci, A.A.; Salva, H.R.; Chaves, C.A.; Velez, J.M.

    2009-01-01

    This paper proposes relationships between the internal friction and the microstructure of two steels containing 0.626 and 0.71 wt.% carbon. The steels were annealed at 1093 K for 5 min, quenched into water and tempered for 10 min at 423, 573 and 723 K. Internal friction was measured by using a forced vibration pendulum, in a temperature range from 100 to 450 K. The internal friction spectrum is decomposed into four peaks: P1 at 215 K, P2 at 235 K, P3 at 260 K and P4 at 380 K for 3 Hz. Peak P1 is attributed to the interactions between dislocations and carbon atoms. Peak P2 is related to the interaction between dislocations and carbide. Peak P3 is related to the generations of kink - pairs along edge dislocations. Peak P4 is attributed to epsilon carbide precipitation.

  5. Analysis of SMELS and reference materials for validation of the k0-based internal monostandard NAA method using in-situ detection efficiency

    Science.gov (United States)

    Acharya, R.; Swain, K. K.; Reddy, A. V. R.

    2010-10-01

    Three synthetic multielement standards (SMELS I, II and III) and two reference materials (RMs), SL-3 and Soil-7 of IAEA were analyzed for validation of the k0-based internal monostandard neutron activation analysis (IM-NAA) method utilizing in-situ relative detection efficiency. The internal monostandards used in SMELS and RMs were Au and Sc, respectively. The samples were irradiated in Apsara and Dhruva reactors, BARC and radioactive assay was carried out using a 40% relative efficiency HPGe detector coupled to an 8 k MCA. Concentrations of 23 elements were determined in both SMELS and RMs. In the case of RMs, concentrations of a few elements, whose certified values are not available, could also be determined. The % deviations for the elements determined in SMELS with respect to the assigned values and RMs with respect to certified values were within ±8%. The Z-score values at 95% confidence level for most of the elements in both the materials were within ±1.

  6. International comparison of observation-specific spatial buffers

    DEFF Research Database (Denmark)

    Frank, Lawrence D; Fox, Eric H; Ulmer, Jared M

    2017-01-01

    the relative differences in resulting explanatory power on self-reported physical activity outcomes. BEMs were developed in five countries using 'sausage,' 'detailed-trimmed,' and 'detailed,' network buffers at a distance of 1 km around participant household addresses (n = 5883). RESULTS: BEM values were...... significantly different (p trimmed buffer comparisons and 89% of sausage versus detailed network buffer comparisons. Results showed that BEM coefficients in physical activity models did not differ significantly across buffering methods, and in most cases BEM...

  7. On the book thickness of $k$-trees

    OpenAIRE

    Dujmović, Vida; Wood, David R.

    2009-01-01

    Graphs and Algorithms; International audience; Every k-tree has book thickness at most k + 1, and this bound is best possible for all k \\textgreater= 3. Vandenbussche et al. [SIAM J. Discrete Math., 2009] proved that every k-tree that has a smooth degree-3 tree decomposition with width k has book thickness at most k. We prove this result is best possible for k \\textgreater= 4, by constructing a k-tree with book thickness k + 1 that has a smooth degree-4 tree decomposition with width k. This s...

  8. Susi hotelli kõrvale kerkib 30-meetrine tuletorn / Erki Varma

    Index Scriptorium Estoniae

    Varma, Erki

    2002-01-01

    Sõjaväearhitekt Johann Ostrat (1894-1979) kavandas 1936. a. Tallinna Sõjamäele viie hektari suuruse pargi, mille kohal oleks kõrgunud 130 m lift ja igavese tulega torn. Jüriöö Pargi Fond kavatseb planeeritud tuletorni valmis ehitada

  9. Arabic Text Categorization Using Improved k-Nearest neighbour Algorithm

    Directory of Open Access Journals (Sweden)

    Wail Hamood KHALED

    2014-10-01

    Full Text Available The quantity of text information published in Arabic language on the net requires the implementation of effective techniques for the extraction and classifying of relevant information contained in large corpus of texts. In this paper we presented an implementation of an enhanced k-NN Arabic text classifier. We apply the traditional k-NN and Naive Bayes from Weka Toolkit for comparison purpose. Our proposed modified k-NN algorithm features an improved decision rule to skip the classes that are less similar and identify the right class from k nearest neighbours which increases the accuracy. The study evaluates the improved decision rule technique using the standard of recall, precision and f-measure as the basis of comparison. We concluded that the effectiveness of the proposed classifier is promising and outperforms the classical k-NN classifier.

  10. Studies in stellar evolution. 3. The internal structure constants

    International Nuclear Information System (INIS)

    Hejlesen, P.M.

    1987-01-01

    This is the third paper in a series describing the results of extensive stellar evolution calculations. The internal structure constants k j (j = 2, 3, 4) have been computed for a fine grid of stellar models covering the HR-diagram from the zero-age main sequence to the subgiant region. These constants represent the influence of the internal structure on the disturbing potentials of stars, and they are needed for prediction of theoretical apsidal motion rates in close eccentric binaries as well as for other tidal effects. Results for four different initial chemical compositions are presented. The opacity tables by Cox and Stewart (1969) have been adopted, and a mixing length parameter of l/H p = 2.0 has been used throughout. The results are compared with previous calculations. A comparison with observational data for eclipsing binaries will be published elsewhere

  11. Measurement of the MACS of {sup 181}Ta(n,γ) at kT=30 keV as a test of a method for Maxwellian neutron spectra generation

    Energy Technology Data Exchange (ETDEWEB)

    Praena, J., E-mail: jpraena@us.es [Universidad de Sevilla (Spain); Centro Nacional de Aceleradores, Sevilla (Spain); Mastinu, P.F. [Laboratori Nazionali di Legnaro, INFN, Padova (Italy); Pignatari, M. [Department of Physics, University of Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland); Quesada, J.M. [Universidad de Sevilla (Spain); García-López, J. [Universidad de Sevilla (Spain); Centro Nacional de Aceleradores, Sevilla (Spain); Lozano, M. [Universidad de Sevilla (Spain); Dzysiuk, N. [International Nuclear Safety Center of Ukraine, Kyiv (Ukraine); Capote, R. [NAPC–Nuclear Data Section, International Atomic Energy Agency, Vienna (Austria); Martín-Hernández, G. [Centro de Aplicaciones Tecnólogicas y Desarrollo Nuclear, 5ta y 30, Playa, La Habana (Cuba)

    2013-11-01

    Measurement of the Maxwellian-Averaged Cross-Section (MACS) of the {sup 181}Ta(n,γ) reaction at kT=30 keV by the activation technique using an innovative method for the generation of Maxwellian neutron spectra is presented. The method is based on the shaping of the proton beam to produce a desired neutron spectrum using the {sup 7}Li(p,n) reaction as a neutron source. The characterization of neutron spectra has been performed by combining measured proton distributions, an analytical description of the differential neutron yield in angle and energy of the {sup 7}Li(p,n) reaction, and with Monte Carlo simulations of the neutron transport. A measured value equal to 815±73 mbarn is reported for the MACS of the reaction {sup 181}Ta(n,γ) at kT=30 keV. The MACS of the reaction {sup 197}Au(n,γ) provided by KADoNiS has been used as a reference. -- Author-Highlights: • Generation of Maxwellian neutron spectrum for astrophysics and nuclear data validation. • {sup 7}Li(p,n) reaction and proton distributions conformed by aluminum as a shaper foil. • Measurement of the proton distributions and simulation of the neutron transport. • MACS of {sup 181}Ta(n,γ) at kT=30 keV measured by the activation technique. • First accelerator-based neutron source in Spain.

  12. Use of sewage treatment biogas for electric generation using an 30 kW (ISO); Uso do biogas de tratamento de esgoto, para geracao de energia eletrica, utilizando-se de uma microturbina de 30 kW (ISO)

    Energy Technology Data Exchange (ETDEWEB)

    Coelho, Suani T.; Velazquez, Silvia M.S.G.; Martins, Osvaldo S.; Costa, David F. [Centro Nacional de Referencia em Biomassa (CENBIO), Sao Paulo, SP (Brazil); Bacic, Antonio C.K. [Companhia de Saneamento Basico do Estado de Sao Paulo (SABESP), SP (Brazil)

    2004-07-01

    This paper intends to present some considerations directed to electricity generation with 30 kW (ISO) micro turbines, using biogas generated by sewage treatment process in SABESP (Basic Sanitation Company of Sao Paulo State), located at Barueri, Brazil. This project, pioneer in Latin America, is being accomplished together with BUN - Biomass Users Network of Brazil (proponent), in association with CENBIO - The Brazilian Reference Center on Biomass (executer), with patronage of FINEP / CT-ENERG (financial backer), by means of ACCORD No: 23.01.0653.00, regarding to ENERG-BIOG Project - 'Installation and Tests of an Electric Energy Generation Demonstration Unit from Biogas Sewage Treatment'. Thus, the contribution of this paper will be in the presentation of the project results, related with the exploitation of sewer biogas for power generation, as well as bigger details about purification, compression and electricity generation systems (biogas micro turbine) used in the installation. (author)

  13. VLF emissions in the Venus foreshock - Comparison with terrestrial observations

    Science.gov (United States)

    Crawford, G. K.; Strangeway, R. J.; Russell, C. T.

    1993-01-01

    An examination is conducted of ELF/VLF emissions observed in the solar wind upstream of the Venus shock, for the 100 Hz-30 kHz range, using data from the Pioneer Venus Orbiter's electric field detector and magnetometer instruments. Detailed comparisons are made with terrestrial measurements for both the electron and ion foreshocks. The results obtained support the Crawford et al. (1990) identification of the Venus electron foreshock emissions as electron plasma oscillations, whose waves are generated in situ and act to isotropize the electron distributions.

  14. NaK-nitrogen liquid metal MHD converter tests at 30 kw

    Science.gov (United States)

    Cerini, D. J.

    1974-01-01

    The feasibility of electrical power generation with an ambient temperature liquid-metal MHD separator cycle is demonstrated by tests in which a NaK-nitrogen LM-MHD converter was operated at nozzle inlet pressures ranging from 100 to 165 N/sq cm, NaK flow rates from 46 to 72 kg/sec, and nitrogen flow rates from 2.4 to 3.8 kg/sec. The generator was operated as an eight-phase linear induction generator, with two of the eight phases providing magnetic field compensation to minimized electrical end losses at the generator channel inlet and exit.

  15. International Comparisons on Internal Labor Markets and Corporate Performance

    Directory of Open Access Journals (Sweden)

    Joonmo Cho

    2003-12-01

    Full Text Available This paper presents an analytical framework which demonstrates how the structures of corporate internal labor markets are formed within the broader labor and capital market context in the U.S. and Japan. This framework is then used to evaluate labor markets within Korean companies and to identify points of change which might promote greater efficiency. Prior to the Asian economic crisis, Korean conglomerates had large, closed internal labor markets. However, in the aftermath of the crisis, they have pursued structural downsizing and moved to open their labor markets. The empirical evidence introduced in this paper affirms the argument that the first step toward creating a flexible labor market in Korea should begin with establishing an efficient corporate governance structure. This implies that a simple switch from the Japanese paradigm for human resource management to an Anglo-American model or vice-versa may not improve internal labor market performance unless the change is accompanied by a solution to the problems posed by the minority controlling structure of Korean companies. The implications of this study for guiding policy in developing countries having labor market rigidities and underdeveloped corporate governance is clear. Capital market structure and corporate governance systems may provide an appropriate starting point for the development of any policies aimed at building an efficient human resource management system and a flexible labor market.

  16. International and national organizations within nuclear energy

    International Nuclear Information System (INIS)

    Sandstroem, S.

    1975-03-01

    A survey is given of the organization, objective and action of international and national organizations working with nuclear energy. Five types of organizations are treated: international governmental organizations, international non-governmental organizations, international organizations dealing with ionizing radiation, nordic organizations, and Swedish organizations. Special attention is payed to the Swedish participation in the different organizations. (K.K)

  17. Partial molar volumes of organic solutes in water. XXVII. Two aliphatic polyethers (triglyme, tetraglyme) at temperatures T = 298–573 K and pressures up to 30 MPa

    International Nuclear Information System (INIS)

    Cibulka, Ivan

    2016-01-01

    Highlights: • Standard molar volumes of two linear aliphatic polyethers in water are presented. • Data were obtained in the range T from (298 to 573) K and p up to 30 MPa. • Data combined with those obtained previously are analyzed and compared with standard molar volumes of cyclic ethers. - Abstract: Densities of dilute aqueous solutions of two linear aliphatic polyethers: 2,5,8,11-tetraoxadodecane (triethylene glycol dimethyl ether, triglyme) and 2,5,8,11,14-pentaoxapentadecane (tetraethylene glycol dimethyl ether, tetraglyme), measured in the temperature range from (298 to 573) K and at pressures up to 30 MPa using an automated flow vibrating-tube densimeter are reported. Standard molar volumes were evaluated from the measured data. The present values complement previous measurements performed for the title polyethers at atmospheric pressure in the temperature range from (278 to 343) K and extend the knowledge to temperature and pressure ranges in which the data on standard molar volumes for lower members of the homologous series (monoglyme, diglyme) are already available.

  18. Survey of the small (300 W to 300 kW) wind turbine market in Canada

    International Nuclear Information System (INIS)

    2005-01-01

    The significant growth in the Canadian wind power industry over the past decade has resulted in an increased number of large utility-scale wind farms appearing across Canada. Although large wind turbines are often acknowledged as a mature technology that can provide clean, reliable and economically competitive power, smaller wind turbines have had relatively little documentation in comparison. The aim of this report was to provide a profile of the Canadian market for small wind turbines (SWTs), divided into 3 categories: mini wind turbines with a rated power output from 300 watts to 1000 watts; small wind turbines up to 30 kW; and medium-sized wind turbines up to 300 kW. Study findings were based on interviews with industry experts and a comprehensive survey of 135 companies involved in the Canadian SWT industry. Details of annual sales and total installed capacity were provided, as well as a summary of key SWT markets. An overview of Canadian market demand and international SWT manufacturing capacity was presented. Opportunities and barriers were examined. It was observed that experiences in the United States have indicated that SWTs are more successful when combined with enabling policies, market incentives, and education and awareness raising. The U.S. small wind industry has estimated that in the near future, the SWT industry could supply 50,000 MW, employ 10,000 people and generate $1 billion per year. A number of opportunities for the promotion of the small wind industry in Canada were reviewed, including the niche manufacturing sector in the 20 kW to 50 kW range. Issues concerning the economic benefits of a SWT manufacturing industry were examined. It was suggested that as the SWT markets grow and mature, turbine prices are expected to fall and turbine effectiveness and reliability will increase. An SWT promotional strategy was outlined with incentives in 4 areas: (1) market development; (2) policy development; (3) technology development; and (4) education

  19. Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Long Jiang; Qi, Li; Tang, Chun Xiang; Zhou, Chang Sheng; Ji, Xue Man; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Wang, Jing [Medical School of Nanjing University, Department of Cardiology, Jinling Hospital, Nanjing, Jiangsu (China); Spearman, James V.; De Cecco, Carlo Nicola; Meinel, Felix G. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2014-07-15

    To evaluate the feasibility, image quality and radiation dose of prospectively ECG-triggered high-pitch coronary CT angiography (CCTA) with 30 mL contrast agent at 70 kVp. Fifty-eight patients with suspected coronary artery disease, a body mass index (BMI) of less than 25 kg/m{sup 2}, sinus rhythm and a heart rate (HR) of less than 70 beats per minute (bpm) were prospectively enrolled in this study. Thirty mL of 370 mg I/mL iodinated contrast agent was administrated at a flow rate of 5 mL/s. All patients underwent prospectively ECG-triggered high-pitch CCTA on a second-generation dual-source CT system at 70 kVp using automated tube current modulation. Fifty-six patients (96.6 %) had diagnostic CCTA images and two patients (3.4 %) had one vessel with poor image quality each rated as non-diagnostic. No significant effects of HR, HR variability and BMI on CCTA image quality were observed (all P > 0.05). Effective dose was 0.17 ± 0.02 mSv and the size-specific dose estimate was 1.03 ± 0.13 mGy. Prospectively ECG-triggered high-pitch CCTA at 70 kVp with 30 mL of contrast agent can provide diagnostic image quality at a radiation dose of less than 0.2 mSv in patients with a BMI of less than 25 kg/m{sup 2} and an HR of less than 70 bpm. (orig.)

  20. International Ocean Discovery Program; Expedition 361 preliminary report; South African climates (Agulhas LGM density profile); 30 January-31 March 2016

    NARCIS (Netherlands)

    Hall, Ian R.; Hemming, Sidney R.; LeVay, Leah J.; Barker, Stephen R.; Berke, Melissa A.; Brentegani, Luna; Caley, Thibaut; Cartagena-Sierra, Alejandra; Charles, Christopher D.; Coenen, Jason J.; Crespin, Julien G.; Franzese, Allison M.; Gruetzner, Jens; Xibin, Han; Hins, Sophia K. V.; Jimenez Espejo, Francisco J.; Just, Janna; Koutsodendris, Andreas; Kubota, Kaoru; Lathika, Nambiyathodi; Norris, Richard D.; Pereira dos Santos, Thiago; Robinson, Rebecca; Rolison, John M.; Simon, Margit H.; Tangunan, Deborah; van der Lubbe, Jeroen (H,) J. L.; Yamane, Masako; Hucai, Zhang

    2016-01-01

    International Ocean Discovery Program (IODP) Expedition 361 drilled six sites on the southeast African margin and in the Indian-Atlantic ocean gateway, southwest Indian Ocean, from 30 January to 31 March 2016. In total, 5175 m of core was recovered, with an average recovery of 102%, during 29.7 days

  1. rBCG30-induced immunity and cross-protection against Mycobacterium leprae challenge are enhanced by boosting with the Mycobacterium tuberculosis 30-kilodalton antigen 85B.

    Science.gov (United States)

    Gillis, Thomas P; Tullius, Michael V; Horwitz, Marcus A

    2014-09-01

    Leprosy remains a major global health problem and typically occurs in regions in which tuberculosis is endemic. Vaccines are needed that protect against both infections and do so better than the suboptimal Mycobacterium bovis BCG vaccine. Here, we evaluated rBCG30, a vaccine previously demonstrated to induce protection superior to that of BCG against Mycobacterium tuberculosis and Mycobacterium bovis challenge in animal models, for efficacy against Mycobacterium leprae challenge in a murine model of leprosy. rBCG30 overexpresses the M. tuberculosis 30-kDa major secretory protein antigen 85B, which is 85% homologous with the M. leprae homolog (r30ML). Mice were sham immunized or immunized intradermally with BCG or rBCG30 and challenged 2.5 months later by injection of viable M. leprae into each hind footpad. After 7 months, vaccine efficacy was assessed by enumerating the M. leprae bacteria per footpad. Both BCG and rBCG30 induced significant protection against M. leprae challenge. In the one experiment in which a comparison between BCG and rBCG30 was feasible, rBCG30 induced significantly greater protection than did BCG. Immunization of mice with purified M. tuberculosis or M. leprae antigen 85B also induced protection against M. leprae challenge but less so than BCG or rBCG30. Notably, boosting rBCG30 with M. tuberculosis antigen 85B significantly enhanced r30ML-specific immune responses, substantially more so than boosting BCG, and significantly augmented protection against M. leprae challenge. Thus, rBCG30, a vaccine that induces improved protection against M. tuberculosis, induces cross-protection against M. leprae that is comparable or potentially superior to that induced by BCG, and boosting rBCG30 with antigen 85B further enhances immune responses and protective efficacy. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  2. Measuring internal friction at sonic and ultrasonic frequencies in high temperature superconductors

    International Nuclear Information System (INIS)

    Anderson, A.R.; Russell, G.J.

    1996-01-01

    Internal friction measurements provide a sensitive means for probing some structural properties of materials. Defect relaxation processes and phase changes are frequently reflected in internal friction measurements as a function of temperature. Relaxation processes associated with oxygen content have been observed in YBCO and BSCCO (2212). By measuring the internal friction at different frequencies activation energies associated with relaxation processes can be determined. Structural changes are temperature dependent and independent of frequency. The composite bar technique developed employs a piezoelectric quartz bar (with lengths of 2 cm or 3 cm and resonant frequencies of approximately 85 kHz or 120 kHz) with a resonant bar of HTSC attached to one end. The quartz bar is suspended at its nodal points and the system excited electrically using a regenerative feedback system. The composite bar method can also be used at low kilohertz frequencies by attaching the HTSC specimen used in the previous technique to the end of a much longer (e g 30 cm) fused silica rod which has very low damping. The resulting composite bar can be excited electrostatically or electromagnetically at frequencies below 10 kHz. The internal friction can be measured by scanning through the resonant frequency and measuring the bandwidth or by observing the decay of free oscillation in the bar. The advantage of using the two composite bar techniques is that the measurements can be made on the same specimen at different frequencies

  3. Robust K-Median and K-Means Clustering Algorithms for Incomplete Data

    Directory of Open Access Journals (Sweden)

    Jinhua Li

    2016-01-01

    Full Text Available Incomplete data with missing feature values are prevalent in clustering problems. Traditional clustering methods first estimate the missing values by imputation and then apply the classical clustering algorithms for complete data, such as K-median and K-means. However, in practice, it is often hard to obtain accurate estimation of the missing values, which deteriorates the performance of clustering. To enhance the robustness of clustering algorithms, this paper represents the missing values by interval data and introduces the concept of robust cluster objective function. A minimax robust optimization (RO formulation is presented to provide clustering results, which are insensitive to estimation errors. To solve the proposed RO problem, we propose robust K-median and K-means clustering algorithms with low time and space complexity. Comparisons and analysis of experimental results on both artificially generated and real-world incomplete data sets validate the robustness and effectiveness of the proposed algorithms.

  4. W-Band InP Wideband MMIC LNA with 30K Noise Temperature

    Science.gov (United States)

    Weinreb, S.; Lai, R.; Erickson, N.; Gaier, T.; Wielgus, J.

    2000-01-01

    This paper describe a millimeter wave low noise amplifier with extraordinary low noise, low consumption, and wide frequency range. These results are achieved utilizing state-of-the-art InP HEMT transistors coupled with CPW circuit design. The paper describes the transistor models, modeled and measured on-wafer and in-module results at both 300K am 24K operating temperatures for many samples of the device.

  5. A study of peripherally produced K+K--pairs in the reaction π-p → K+K-n at 18.4 GeV/c

    International Nuclear Information System (INIS)

    Hentschel, G.

    1976-09-01

    We have measured 27,008 events at small p-n four momentum transfers, determined resonance and differential cross sections and branching ratios. As one result of the analysis we find the s-wave enhancement at threshold, which reaches the unitarity limit in the extrapolated data. As a further result we have determined the parameters of the PHI-meson to be M(PHI) = 1,018.4 +- 0.7 MeV, Gamma(phi) = 4.5 +- sup(2.2)sub(2.1) MeV and a cross section sigmasub(phi → KantiK) = (58 +- sup(2.7)sub(1.6)) μb. A comparison of the cross sections for ω- and phi-production shows the same dependence on incident beam momentum. The rho-exchange amplitude gives a good fit to the observed Treiman-Yang-angle distribution. For the ω-phi-mixing angle we get theta 1 = (41 +- sup(5.7)sub(4.7)) 0 and theta 2 = (29.3 +- sup(5.7)sub(4.7)) 0 . In comparison with other experiments we find no dependence on beam momentum. Above 1,500 MeV the decay g 0 → K + K - and the production of a new resonance, the h-meson, are observed the first time experimentally. The resonance parameters are: Msub(g) = 1,692 +- 6 MeV, Gammasub(g) = 205 +- 20 MeV and g → antiKK = 3.15 +- 0.22 μb. Using the results of another experiment we calculate a branching ratio of BR(g → antiKK/g → ππ) = 0.193 +- 0.025. (orig./BJ) [de

  6. Papers presented at the Fourteenth International conference on Plasma Physics and Controlled Nuclear Fusion Research. Organization International de la Energia Atomica Wuerzberg, Alemania 30 September - 7 October 1992

    International Nuclear Information System (INIS)

    1994-01-01

    This report contains the contributions of the CIEMAT's Fusion Unit to the 14th International Conference on Plasma Physics and Controlled Nuclear Fusion Research that was held by the International Atomic Energy Agency in Wuerzberg, Germany from 30 September to 7 October 1992. Three papers were presented that summarized the, main lines of work done in the Unit during the previous two years: The first one on the theoretical advances in the understanding of the Fexible Heliac TJ-II under construction, the second on the confinement studies performed in the operating TJ-I Tokamak and the third one on the description of the physical properties of the soon to be started TJ-IU Torsatron. (Author) 25 refs

  7. Preliminary results for the k0-INAA methodology implementation at the Neutron Activation Analysis Laboratory, LAN-IPEN, using k0-IAEA software

    International Nuclear Information System (INIS)

    Mariano, Davi B.; Figueiredo, Ana Maria G.; Semmler, Renato

    2009-01-01

    The present paper presents the preliminary results obtained in the implementation of the k 0 standardization method at the Neutron Activation Laboratory (LAN) at IPEN, Sao Paulo, Brazil, using the program k 0 -IAEA, provided by The International Atomic Energy Agency (IAEA). This method is an important alternative for the comparative neutron activation analysis, which has been used for several years at LAN-IPEN. This quasiabsolute standardization method presents a great advantage with relation to the comparative method, since it does not require the preparation of accurate individual standards for each analysed element, which is very laborious and time-consuming. The k 0 method allows the determination of almost all elements whose gammaray peaks are present in the gamma spectrum. The analysis of gamma-ray spectra and the calculation of concentration are performed by the k 0 software, thus the analysis time is shortened: the time spent to calculate, for instance, the concentration of 25 elements in 10 samples takes about 5 minutes.The efficiency curve of one of the gamma-ray spectrometers used at LAN was determined by measuring calibrated radioactive sources at the usually utilised counting geometries. The parameters α and f were determined by irradiating a Certified Nuclear Reference Material IRMM-530R Al-0,1% Au alloys and high purity zirconium comparators at the IEA-R1 nuclear reactor of IPEN. In order to evaluate the efficiency of the methodology, the geological reference material basalt JB-1 (GSJ) was analysed. The preliminary results obtained showed promising results in spite of some discrepancies of the data in comparison to certified values. These preliminary results indicate that some improvements in the parameters required for the use of the k 0 -IAEA software should be made so that the k 0 - NAA software can be completely successful. (author)

  8. Effects of process parameters on microstructure and mechanical properties of friction stir lap linear welded 6061 aluminum alloy to NZ30K magnesium alloy

    Directory of Open Access Journals (Sweden)

    Shuai Tan

    2017-03-01

    Full Text Available The microstructures and lap-shear behaviors of friction stir lap linear welded as-extruded 6061 Al alloy to as-cast Mg–3.0Nd–0.2Zn–0.7Zr (wt.% (NZ30K alloy joints were examined. Various tool rotation and travel speeds were adopted to prepare the joints. The analysis of temperature field indicates that the peak temperature for each sample can reach 450 °C, which exceeds the eutectic reaction temperatures of 437 °C and 450 °C according to the binary phase diagram of Al–Mg system. The fierce intermixing can be found at the interface between Al and Mg alloys, forming the intermetallic of Al3Mg2. Welds with the rotation speed of 900 rpm and travel speed of 120 mm/min display the highest tensile shear failure load of about 2.24 kN. The value was increased by 13% after the sample was heat treated at 400 °C for 0.5 h.

  9. Comparison of Single Visit Post Endodontic Pain Using Mtwo Rotary and Hand K-File Instruments: A Randomized Clinical Trial.

    Science.gov (United States)

    Kashefinejad, Mohamad; Harandi, Azade; Eram, Saeed; Bijani, Ali

    2016-01-01

    Pain is an unpleasant outcome of endodontic treatment that can be unbearable to patients. Instrumentation techniques may affect the frequency and intensity of post-endodontic pain. This study aimed to compare single visit post endodontic pain using Mtwo (NiTi) rotary and hand K-file instruments. In this randomized controlled trial, 60 teeth with symptomatic irreversible pulpitis in 53 patients were selected and randomly assigned into two groups of 30 teeth. In group A, the root canals were prepared with Mtwo (NiTi) rotary instruments. In group B, the root canals were prepared with hand K-file instruments. Pain assessment was implemented using visual analog scale (VAS) at four, eight, 12 and 24 hours after treatment. The acquired data were analyzed using chi-square, Mann-Whitney U and Student's t-test (Protary instruments experienced significantly less post-endodontic pain than those treated with hand instruments (Protary instruments in root canal preparation contributed to lower incidence of postoperative pain than hand K-files.

  10. k0-INAA application at IPEN Neutron Activation Laboratory by using the k0-IAEA program: biological sample analysis

    International Nuclear Information System (INIS)

    Puerta, Daniel Correa

    2013-01-01

    The results obtained in the application of the k 0 -standardization method at LAN-IPEN for biological matrices analysis, by using the k 0 -IAEA software, provided by the International Atomic Energy Agency (IAEA), are presented. The flux parameters f and a of the IEA-R1 reactor were determined for the pneumatic irradiation facility and for one selected irradiation position, 24B/shelf2, for short and long irradiations, respectively. In order to obtain these parameters, the bare triple-monitor method with 197 Au- 96 Zr- 94 Zr was used. In order to evaluate the accuracy and precision of the methodology, the biological reference materials Peach Leaves (NIST SRM 1547), Mixed Polish Herbs (INCT-MPH-2) e Tomato Leaves (NIST SRM 1573a) were analyzed. The statistical criteria Relative Errors (bias, %), Coefficient of Variation (CV) and U-score were applied to the obtained results (mean of six replicates). The relative errors (bias, %) in relation to certified values, were, for most elements, in the range of 0 e 30. The Coefficients of Variation were below 20%, showing a good reproducibility of the results. The U-score test showed that all results, except Na in Peach Leaves and in Tomato Leaves, were within 95% confidence interval. These results point out to a promising use of the k 0 -INAA method at LAN-IPEN for biological sample analysis. (author)

  11. Prevalence of obesity among Arab school children in Nazareth, Israel: comparison with national (Jewish) and international data.

    Science.gov (United States)

    Ram, E; Marcus, O; Joubran, S; Abdo, B; Asal, N R

    2013-12-01

    Lack of published data. Absence of Ethnic specific data. Lack of focus on obesity prevention in Arab schools. First set of data on obesity for Arab children. Data will be used as reference data. Alert health/school official for intervention. Objective The objective is to produce the first set of obesity prevalence data and use the data as reference values of body mass index (BMI) trends for Arab children in Israel and compare with Jewish and international data. Methods A prevalence study was carried out in 2009 in which 4130 children aged 6-12, were selected from eight Arab sector schools representing the Nazareth Municipality. Height, weight and BMI measurements were obtained and presented by age, mean age, size, weight, gender and percentile. Appropriate epidemiological and statistical methods used for comparison. Results The obesity and overweight prevalence rates in Arab children by age ranges from 0% to 2.6% and 0% to 11.2%, respectively. Comparison with international and Jewish data revealed differences in almost all age groups but higher rates in Arabs, especially boys. Discussion The higher rates/trends in Arab children may be explained by more Arab women entering the workforce, increase in single-parent families and changes in food and physical activity environments. Conclusion Based on our data, we recommend either an ethnic-specific BMI reference curves and/or inclusion of Arab data in the Israeli data system. Research need to focus on reasons for the increase and interventions to reverse/slow the trend. © 2013 The Authors. Pediatric Obesity © 2013 International Association for the Study of Obesity.

  12. On the nature of low temperature internal friction peaks in metallic glasses

    Energy Technology Data Exchange (ETDEWEB)

    Khonik, V.A. [State Pedagogical Univ., Voronezh (Russian Federation); Spivak, L.V. [State Univ., Perm (Russian Federation)

    1996-01-01

    Low temperature (30 < T < 300 K) internal friction in a metallic glass Ni{sub 60}Nb{sub 40} subjected to preliminary inhomogeneous deformation by cold rolling, homogeneous tensile deformation or electrolytic charging with hydrogen is investigated. Cold rolling or hydrogenation result in appearance of similar internal friction peaks and hysteresis damping. Homogeneous deformation has no influence on low temperature internal friction. The phenomenon of microplastic deformation during hydrogenation of weakly stressed samples is revealed. It is argued that microplastic deformation of metallic glasses during hydrogenation without external stress takes place too. Plastic flow both on cold rolling and hydrogenation occurs via formation and motion of dislocation-like defects which are the reason of the observed anelastic anomalies. It is concluded that low temperature internal friction peaks described in the literature for as-cast, cold deformed and hydrogenated samples have common dislocation-like origin.

  13. Myocardial Na,K-ATPase: Clinical aspects

    OpenAIRE

    Kjeldsen, Keld

    2003-01-01

    The specific binding of digitalis glycosides to Na,K-ATPase is used as a tool for Na,K-ATPase quantification with high accuracy and precision. In myocardial biopsies from patients with heart failure, total Na,K-ATPase concentration is decreased by around 40%; a correlation exists between a decrease in heart function and a decrease in Na,K-ATPase concentration. During digitalization, around 30% of remaining pumps are occupied by digoxin. Myocardial Na,K-ATPase is also influenced by other drugs...

  14. A comparison between two powder compaction parameters of plasticity: the effective medium A parameter and the Heckel 1/K parameter.

    Science.gov (United States)

    Mahmoodi, Foad; Klevan, Ingvild; Nordström, Josefina; Alderborn, Göran; Frenning, Göran

    2013-09-10

    The purpose of the research was to introduce a procedure to derive a powder compression parameter (EM A) representing particle yield stress using an effective medium equation and to compare the EM A parameter with the Heckel compression parameter (1/K). 16 pharmaceutical powders, including drugs and excipients, were compressed in a materials testing instrument and powder compression profiles were derived using the EM and Heckel equations. The compression profiles thus obtained could be sub-divided into regions among which one region was approximately linear and from this region, the compression parameters EM A and 1/K were calculated. A linear relationship between the EM A parameter and the 1/K parameter was obtained with a strong correlation. The slope of the plot was close to 1 (0.84) and the intercept of the plot was small in comparison to the range of parameter values obtained. The relationship between the theoretical EM A parameter and the 1/K parameter supports the interpretation of the empirical Heckel parameter as being a measure of yield stress. It is concluded that the combination of Heckel and EM equations represents a suitable procedure to derive a value of particle plasticity from powder compression data. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. The application of the k0-standardization method at the TRIGA Mark II reactor, Ljubljana, Slovenia

    International Nuclear Information System (INIS)

    Jacimovic, Radojko; Benedik, Ljudmila; Stegnar, Peter; Smodis, Borut

    2002-01-01

    The k 0 -standardization method of neutron activation analysis (k 0 -NAA) was launched in the 1970s and since then continuously developed. Nowadays, k 0 -NAA became widespread as a practical analytical tool used to analyse different sample matrices. At the Jozef Stefan Institute (IJS), the KAYZERO/SOLCOI software package has been introduced for data processing after extensive testing and comparison with other available programs. In the process of validation of the software a suite of natural matrix reference materials (RMs) were used. Five certified reference materials (CRMs) from the Institute for Reference Materials and Measurements (IRMM), two standard reference materials (SRMs) from the National Institute of Standards and Technology (NIST), three RMs from the International Atomic Energy Agency (IAEA) and one RM from IJS were analysed. Altogether, results for ten elements in inorganic matrices and twenty-one elements in organic matrices, obtained by k 0 -instrumental neutron activation analysis (k 0 -INAA), were compared to certified values. The results obtained show good agreement with certified or assigned values except for Fe and U in inorganic matrices, and Al and Cr in organic matrices. (author)

  16. Longitudinal Relationships among Internalization of the Media Ideal, Peer Social Comparison, and Body Dissatisfaction: Implications for the Tripartite Influence Model

    Science.gov (United States)

    Rodgers, Rachel F.; McLean, Siân A.; Paxton, Susan J.

    2015-01-01

    Sociocultural theory of body dissatisfaction posits that internalization of the media ideal and appearance comparison are predictors of body dissatisfaction, a key risk factor for eating disorders. However, no data exist regarding the longitudinal relationships between these variables. The aim of this study was to explore longitudinal…

  17. Third International Fuel Cell Conference. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-30

    The Third International Fuel Cell Conference was held on November 30 to December 3, 1999 in City of Nagoya. A total of 139 papers, including those for plenary, sectional and poster cessions, were presented. In the plenary session, US's DOE presented fuel cell power plant development in the United States, EC fuel cells in perspective and fifth European framework programme, and Japan overview of the New Sunshine Program. In the polymer electrolyte fuel cells sessions, 23 papers were presented, including current status of commercialization and PEMFC systems developed by Toshiba. In the phosphoric acid fuel cells session, 6 papers were presented, including field test results and market developments. In the molten carbonate fuel cells session, 24 papers were presented, including development of 1,000kW MCFC power plant. In the solid oxide fuel cells session, 20 papers were presented, including 100kW SOFC field test results. The other topics include market analysis and fuel processes. (NEDO)

  18. Third International Fuel Cell Conference. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-30

    The Third International Fuel Cell Conference was held on November 30 to December 3, 1999 in City of Nagoya. A total of 139 papers, including those for plenary, sectional and poster cessions, were presented. In the plenary session, US's DOE presented fuel cell power plant development in the United States, EC fuel cells in perspective and fifth European framework programme, and Japan overview of the New Sunshine Program. In the polymer electrolyte fuel cells sessions, 23 papers were presented, including current status of commercialization and PEMFC systems developed by Toshiba. In the phosphoric acid fuel cells session, 6 papers were presented, including field test results and market developments. In the molten carbonate fuel cells session, 24 papers were presented, including development of 1,000kW MCFC power plant. In the solid oxide fuel cells session, 20 papers were presented, including 100kW SOFC field test results. The other topics include market analysis and fuel processes. (NEDO)

  19. Cloning and characterization of BmK86, a novel K+-channel blocker from scorpion venom

    International Nuclear Information System (INIS)

    Mao, Xin; Cao, Zhijian; Yin, Shijin; Ma, Yibao; Wu, Yingliang; Li, Wenxin

    2007-01-01

    Scorpion venom represents a tremendous hitherto unexplored resource for understanding ion channels. BmK86 is a novel K + -channel toxin gene isolated from a cDNA library of Mesobuthus martensii Karsch, which encodes a signal peptide of 22 amino acid residues and a mature toxin of 35 residues with three disulfide bridges. The genomic sequence of BmK86 consists of two exons disrupted by an intron of 72 bp. Comparison with the other scorpion toxins BmK86 shows low sequence similarity. The GST-BmK86 fusion protein was successfully expressed in Escherichia coli. The fusion protein was cleaved by enterokinase and the recombinant BmK86 was purified by HPLC. Using whole-cell patch-clamp recording, the recombinant BmK86 was found to inhibit the potassium current of mKv1.3 channel expressed in COS7 cells. These results indicated that BmK86 belongs to a representative member of a novel subfamily of α-KTxs. The systematic number assigned to BmK86 is α-KTx26.1

  20. In Vitro Characterization and Evaluation of the Cytotoxicity Effects of Nisin and Nisin-Loaded PLA-PEG-PLA Nanoparticles on Gastrointestinal (AGS and KYSE-30), Hepatic (HepG2) and Blood (K562) Cancer Cell Lines.

    Science.gov (United States)

    Goudarzi, Fariba; Asadi, Asadollah; Afsharpour, Maryam; Jamadi, Robab Hassanvand

    2018-05-01

    The aim of this study was an in vitro evaluation and comparison of the cytotoxic effects of free nisin and nisin-loaded PLA-PEG-PLA nanoparticles on gastrointestinal (AGS and KYSE-30), hepatic (HepG2), and blood (K562) cancer cell lines. To create this novel anti-cancer drug delivery system, the nanoparticles were synthesized and then loaded with nisin. Subsequently, their biocompatibility, ability to enter cells, and physicochemical properties, including formation, size, and shape, were studied using hemolysis, fluorescein isothiocyanate (FITC), Fourier transform infrared (FTIR) spectroscopy, dynamic light scattering (DLS), and scanning electron microscopy (SEM), respectively. Then, its loading efficiency and release kinetics were examined to assess the potential impact of this formulation for the nanoparticle carrier candidacy. The cytotoxicities of nisin and nisin-loaded nanoparticles were evaluated by using the MTT and Neutral Red (NR) uptake assays. Detections of the apoptotic cells were done via Ethidium Bromide (EB)/Acridine Orange (AO) staining. The FTIR spectra, SEM images, and DLS graph confirmed the formations of the nanoparticles and nisin-loaded nanoparticles with spherical, distinct, and smooth surfaces and average sizes of 100 and 200 nm, respectively. The loading efficiency of the latter nanoparticles was about 85-90%. The hemolysis test represented their non-cytotoxicities and the FITC images indicated their entrance inside the cells. An increase in the percentage of apoptotic cells was observed through EB/AO staining. These results demonstrated that nisin had a cytotoxic effect on AGS, KYSE-30, HepG2, and K562 cancer cell lines, while the cytotoxicity of nisin-loaded nanoparticles was more than that of the free nisin.