WorldWideScience

Sample records for cavity administered iodine-131-labeled

  1. Tumor resection cavity administered iodine-131-labeled antitenascin 81C6 radioimmunotherapy in patients with malignant glioma: neuropathology aspects

    Energy Technology Data Exchange (ETDEWEB)

    McLendon, Roger E. [Department of Pathology, Duke University Medical Center, Durham, NC 27710 (United States)]. E-mail: mclen001@mc.duke.edu; Akabani, Gamal [Department of Radiology, Duke University Medical Center, Durham, NC 27710 (United States); Friedman, Henry S. [Department of Pediatrics, Duke University Medical Center, Durham, NC 27710 (United States); Reardon, David A. [Department of Medicine, Duke University Medical Center, Durham, NC 27710 (United States); Cleveland, Linda [Department of Pathology, Duke University Medical Center, Durham, NC 27710 (United States); Cokgor, Ilkcan [Department of Pediatrics, Duke University Medical Center, Durham, NC 27710 (United States); Herndon, James E. [Department of Biostatistics and Bioinformatics, Duke University Medical Center, Durham, NC 27710 (United States); Wikstrand, Carol [Department of Pathology, Duke University Medical Center, Durham, NC 27710 (United States); Boulton, Susan T. [Department of Surgery, Duke University Medical Center, Durham, NC 27710 (United States); Friedman, Allan H. [Department of Surgery, Duke University Medical Center, Durham, NC 27710 (United States); Bigner, Darell D. [Department of Pathology, Duke University Medical Center, Durham, NC 27710 (United States); Zalutsky, Michael R. [Department of Radiology, Duke University Medical Center, Durham, NC 27710 (United States)

    2007-05-15

    Introduction: The neurohistological findings in patients treated with targeted {beta} emitters such as {sup 131}I are poorly described. We report a histopathologic analysis from patients treated with combined external beam therapy and a brachytherapy consisting of a {sup 131}I-labeled monoclonal antibody (mAb) injected into surgically created resection cavities during brain tumor resections. Methods: Directed tissue samples of the cavity walls were obtained because of suspected tumor recurrence from 28 patients. Samples and clinical follow-up were evaluated on all patients (Group A) based on total radiation dose received and a subset of these (n=18; Group B, proximal therapy subset) who had received external beam therapy within {<=}3 months of mAb therapy and undergoing 26 biopsies over 37 months. Histologic outcomes were 'proliferative glioma,' 'quiescent glioma' and negative for neoplasm. Statistical analysis was used to assess the casual relation between total absorbed dose ({sup 131}I-mAb+external beam) and histologic diagnosis. Results: The lesions observed after {sup 131}I-mAb therapy were qualitatively similar to those reported for other types of radiation therapy; however, the high localized dose rate and absorbed doses produced by the short range of {sup 131}I {beta} particles seem to have resulted in an earlier necrotic reaction in the tumor bed. Among all 28 (Group A) patients, median survival from tissue analysis after mAb therapy depended on histopathology and total radiation absorbed dose. Median survival for patients with tissue classified as proliferative glioma, quiescent glioma and negative for neoplasm were 3.5, 15 and 27.5 months, respectively. Without categorization, total dose was a significant predictor of survival (P<.002) where patients with higher doses had better prognoses. For example, median survival in patients receiving a total radiation dose greater than 86 Gy was 19 months compared with 7 months for those

  2. Evaluation of pancreatic lipase activity by simple urine analysis after oral administration of a new iodine-131-labeled triglyceride

    International Nuclear Information System (INIS)

    Kropp, J.; Knapp, F.F. Jr.; Weyenberg, A.; McPherson, D.W.; Ambrose, K.R.; Callahan, A.P.; Bergmann, K. von; Biersack, H.J.

    1994-01-01

    A new iodine-131-labeled triglyceride analogue called ''MIPAG'' [1,2-dipalmitoyl-3-[(15-p-iodophenyl) pentadecan-1-oyl]rac-glycerol] has been prepared in which 15-(p-iodophenyl)pentadecanoic acid (IPPA) is attached to position-3. MIPAG has been developed for the evaluation of pancreatic exocrine function by simple urine analysis and has been evaluated in rats and humans. After oral administration, IPPA is released from the triglyceride by the action of pancreatic lipases followed by intestinal absorption and the principal IPPA metabolite (p-iodobenzoic acid. IBA) is primarily excreted in the urine. Excretion in the urine and feces was evaluated in rats, as well as the biodistribution in various organs over 21 days. Twenty patients without pancreatic disease (normals) and four patients with pancreatic insufficiency were also investigated. Following oral administration of 30 μCi of MIPAG, urine was collected for two successive 24-h periods. Blood samples were drawn and thin-layer chromatographic (TLC) analysis was performed on the serum lipid extracts. Urine from normals contained 44.9%±7.7% and 61.8%±8.4% of the administered activity after 24 and 48 h, respectively. The patients with pancreatic insufficiency excreted 13.1%±5.6% and 18.9%±6.2%, respectively, which was significantly decreased (P<0.001) compared with normals. The TLC profiles showed an increasing proportion of IBA with time. Urine analysis after oral administration of MIPAG thus appears to be an attractive new technique for the evaluation of pancreatic lipase activity by a simple urine analysis. (orig.)

  3. Value of continuous leakage monitoring with radioactive iodine-131-labeled human serum albumin during hyperthermic isolated limb perfusion with tumor necrosis factor-alpha and melphalan

    NARCIS (Netherlands)

    van Ginkel, RJ; Limburg, PC; Piers, DA; Hoekstra, HJ; Schraffordt Koops, H.

    Background: The aim of this study was to analyze the value of continuous leakage monitoring with radioactive iodine-131-labeled human serum albumin (RISA) in patients treated with hyperthermic isolated limb perfusion with tumor necrosis factor-alpha (TNFalpha) and melphalan. Methods: Forty-eight

  4. Radioimmunotherapy in medullary thyroid cancer using bispecific antibody and iodine 131-labeled bivalent hapten: preliminary results of a phase I/II clinical trial.

    Science.gov (United States)

    Kraeber-Bodéré, F; Bardet, S; Hoefnagel, C A; Vieira, M R; Vuillez, J P; Murat, A; Ferreira, T C; Bardiès, M; Ferrer, L; Resche, I; Gautherot, E; Rouvier, E; Barbet, J; Chatal, J F

    1999-10-01

    The toxicity and therapeutic efficacy of escalating doses of anti-carcinoembryonic antigen x anti-N alpha-(diethylenetriamine-N,N,N',N''-tetraacetic acid)-In bispecific monoclonal antibody (F6-734) and iodine 131-labeled bivalent hapten were determined in a Phase I/II trial. A total of 26 patients with recurrences of medullary thyroid cancer documented by imaging and a rise in serum thyrocalcitonin were enrolled. Twenty to 50 mg of F6-734 and 40-100 mCi of 131I-hapten were injected 4 days apart. Quantitative scintigraphy was performed after the second injection for dosimetry estimations in eight cases. Clinical, biological, and morphological follow-up was carried out for 1 year after treatment. The mean percentage of injected activity per gram of tumor at the time of maximum uptake was 0.08% (range, 0.003-0.26%). The tumor biological half-life ranged from 3 to 95 days, and tumor doses ranged from 2.91 to 184 cGy/mCi. The estimated tumor-to-nontumor dose ratios were 43.8 x 53.4, 29.6 x 35.3, 10.9 x 13.6, and 8.4 x 10.0 for total body, red marrow, liver, and kidney, respectively. Grade III/IV hematological toxicity was observed in seven patients, most of them with bone metastases. Among the 17 evaluable patients, 4 pain reliefs, 5 minor tumor responses, and 4 biological responses with decrease of thyrocalcitonin were observed. Nine patients developed human anti-mouse antibody. Dose-limiting toxicity was hematological, and maximum tolerated activity was 48 mCi/m2 in this group of patients, most of whom had suspected bone marrow involvement. The therapeutic responses observed in patients mainly with a small tumor burden are encouraging for the performance of a Phase II trial with minimal residual disease.

  5. Thrombus imaging with indium-111 and iodine-131-labeled fibrin-specific monoclonal antibody and its F(ab')2 and Fab fragments

    International Nuclear Information System (INIS)

    Rosebrough, S.F.; Grossman, Z.D.; McAfee, J.G.

    1988-01-01

    We have previously reported successful imaging of fresh (2-4 hr old) and aged (1-5 days old) canine thrombi with 131 I-labeled intact monoclonal antibody (MAb) specific for fibrin. We now report thrombus imaging with 131 I-labeled F(ab')2 and Fab and 111 In-labeled intact MAb, F(ab')2, and Fab. Indium-111-labeled F(ab')2 proved to be the best imaging agent due to less nonspecific binding in the liver than whole IgG. Image quality was improved by the higher administered dose permissible with 111 In and its better physical characteristics for imaging, compared to 131 I. Immunofluorescence of fresh human histologic sections showed intact MAb and F(ab')2 binding to thrombi, pulmonary emboli, and atherosclerotic plaques, strengthening the feasibility of clinical thrombus imaging

  6. Pharmacokinetics and dosimetry studies for optimization of anti-carcinoembryonic antigen x anti-hapten bispecific antibody-mediated pretargeting of Iodine-131-labeled hapten in a phase I radioimmunotherapy trial.

    Science.gov (United States)

    Kraeber-Bodéré, Françoise; Faivre-Chauvet, Alain; Ferrer, Ludovic; Vuillez, Jean-Philippe; Brard, Pierre-Yves; Rousseau, Caroline; Resche, Isabelle; Devillers, Anne; Laffont, Sophie; Bardiès, Manuel; Chang, Ken; Sharkey, Robert M; Goldenberg, David M; Chatal, Jean-François; Barbet, Jacques

    2003-09-01

    Pharmacokinetics and dosimetry of hMN-14 x m734 bispecific monoclonal antibody (BsMAb) and (131)I-labeled di-diethylenetriaminepentaacetic acid-indium ((131)I-hapten) were studied to optimize pretargeted radioimmunotherapy. Thirty-five patients with carcinoembryonic antigen-expressing tumors were included. In a first group of 12 patients, (131)I-trace-labeled BsMAb doses were escalated from 10 to 100 mg/m(2), and 3.7 GBq of (131)I-hapten were administered 7 days later. In a second group, 12 patients received 75 mg/m(2) BsMAb and 2.6-4.2 GBq of (131)I-hapten 5 days later. The BsMAb dose was then reduced to 40 mg/m(2), and 10 patients received 1.9-5.5 GBq of (131)I-hapten. Blood samples were collected. Biodistribution was monitored by quantitative scintigraphy. Directly labeled BsMAb pharmacokinetics was described by two exponentials: half-lives were 8.1 h (2.0-18.1 h) and 48.2 h (22.8-79.4 h); blood clearance was 123 ml/h (64-195 ml/h). With a 7-day interval, 10 or 30 mg/m(2) BsMAb resulted in fast elimination and very low tumor uptake of hapten, whereas 50 or 100 mg/m(2) resulted in favorable tumor accretion. With 75 mg/m(2) BsMAb and a 5-day interval, hapten clearance was 152 ml/h (81-298 ml/h). Calculated radiation dose to tumor was 3.9 Gy/GBq (0.4-22.4 Gy/GBq) for the hapten, compared with 2.0 Gy/GBq (0.3-3.8 Gy/GBq) for the BsMAb, but hematological toxicity prevented dose escalation. Reduction of the BsMAb dose to 40 mg/m(2) accelerated hapten clearance to 492 ml/h (113-2544 ml/h) and reduced hematological toxicity without compromising tumor uptake [5.2 Gy/GBq (0.5-12.6 Gy/GBq)]. Optimized BsMAb doses and time interval will allow for the administration of higher, tumoricidal, activity doses.

  7. Iodine-131 labelled octreotide: Not an option for somatostatin receptor therapy

    NARCIS (Netherlands)

    W.H. Bakker (Willem); W.A.P. Breeman (Wouter); M. van der Pluijm (M.); M. de Jong (Marcel); T.J. Visser (Theo); E.P. Krenning (Eric)

    1996-01-01

    textabstractGamma-emitting radiopeptides are useful for scintigraphy of tumours on the basis of receptor binding. Likewise, β-emitting radiopeptides may be used in radionuclide therapy of such tumours. As iodine-131 suggested to be suitable for this purpose, experiments were performed using three

  8. Iodine-131 labeled anti-CEA polyclonal antibody detection of gastrointestinal cancer

    International Nuclear Information System (INIS)

    Nabi, H.A.; Hinkle, G.H.; Olsen, J.O.; Haagensen, D.A.; Thurston, M.O.; Mojzisik, C.; Houchens, D.; Martin, E.W. Jr.

    1984-01-01

    To localize gastrointestinal tumor, 31 patients were injected with 1.7-2.1 mCi I-131 anti-CEA baboon polyclonal antibody. Whole body imaging at 48, 72, and occasionally 96 hrs was performed with a Signa Camera (Technicare) peaked at 364 keV with 20% window. Additional spot views were usually obtained. No subtraction methods were used. All patients had surgical and pathological confirmation of the nuclear medicine studies. Labeled antibody images were positive in 15 (8 recurrent or metastatic colorectal, 2 gastric, 1 pancreatic, 1 primary colon, and 1 breast metastatic to chest wall). In 1, antibody images were positive for metastatic deposits in para-aortic lymph nodes, but negative for primary rectal tumor. True negative images were observed in 6; false negative images in 9 (4 liver metastases, 2 rectal, 1 pancreatic, 1 mesenteric lymph node metastasis, 1 bone metastasis). In all cases, no correlation existed between preoperative CEA serum levels and imaging. I-131 labeled anti-CEA polyclonal antibody imaging proved highly efficient in detecting gastric cancer (2/2) and moderately efficient in detecting recurrent colorectal cancer (8/15). On the other hand, the I-131 labeled polyclonal anti-CEA antibody imaging was of limited value in detecting colon cancer (1/9), pancreatic cancer (1/4) and metastatic liver disease

  9. Scintigraphic imaging and turnover studies with iodine-131 labelled serum amyloid P component in systemic amyloidosis

    International Nuclear Information System (INIS)

    Hawkins, P.N.; Pepys, M.B.; Aprile, C.; Capri, G.; Vigano, L.; Munzone, E.; Gianni, L.; Merlini, G.

    1998-01-01

    Radiolabelled serum amyloid P component (SAP) is a specific tracer for amyloid. Iodine-123 has ideal physical characteristics for scintigraphy but is expensive and not widely available. Here we report serial imaging and turnover studies in which we labelled SAP with iodine-131, a cheap alternative isotope which would be expected to yield poorer images but permit more prolonged turnover measurements. Imaging and plasma clearance and whole body retention (WBR) of tracer were studied for up to 7 days in ten patients with proven systemic AL amyloidosis and two patients in whom the diagnosis was suspected, after i.v. administration of about 37 MBq of 131 I-SAP. Normal blood pool images were obtained in the latter two subjects and amyloidosis was subsequently refuted histologically. WBR at 48 h was 65% of the injected dose (i.d.). Among the other ten patients, amyloid deposits were identified in the spleen in eight cases, liver in five and kidneys in four; other sites that gave positive results included bone, joints and soft tissues, and the myocardium in one case. Up to 95% of the tracer localised into amyloid within 6-h, and the values for WBR became progressively more discriminating during the study period, exceeding the normal reference value ( 131 I-SAP produced diagnostic scans in every patient in this series and, coupled with the detailed turnover information, is adequate for monitoring disease progress. (orig.)

  10. Iodine-131 labelled octreotide: not an option for somatostatin receptor therapy

    International Nuclear Information System (INIS)

    Bakker, W.H.; Breeman, W.A.P.; Pluijm, M.E. van der; Jong, M. de; Visser, T.J.; Krenning, E.P.

    1996-01-01

    This study deals with the radioiodination of very small amounts of peptide on a therapeutic scale, the required purification procedures after radioiodination, and the influence of high beta fluxes from 131 I on a peptide during radioiodination and purification. Based on the regularly used therapeutic doses of 131 I in cancer treatment and out previous experience with [ 111 In-DTPA-D-Phe 1 ]-octreotide, it was assumed that a minimal effective therapeutic dose of 3.7 GBq 131 I has to be coupled to a maximum of ∼100 μg peptide, representing only a slight excess of peptide over 131 I. This contrasts with non-peptide radiopharmaceuticals in which high compound to radionuclide ratios are usually used. Labelling at low peptide to radionuclide ratios (low labelling yields) results in the formation of di-iodinated compounds, whereas at high peptide to radionuclide ratios mono-iodinated products of low specific activity are formed. Thus, after radioiodination the desired mono-iodinated peptide has to be separated form unreacted iodide, and from di-iodinated and unreacted peptide, as both compounds compete for the receptors. Possible radiolysis of the peptide during labelling and separation steps were investigated by irradiating 30 μg unlabelled peptide with 370 MBq 131 I in a small volume. The peptide composition of the incubation mixtures was investigated by high-performance liquid chromatography after irradiation for 30 min to 24 h. The results showed that the peptide was degraded with a half-life of less than 1 h. During the preparation of a real therapeutic dose (at much higher β-flux) the peptide will be degraded even faster during the various steps required. In conclusion, intact mono-iodinated 131 I-labelled somatostatin analogues for peptide receptor therapy will be difficult to obtain. (orig./VHE)

  11. Iodine 131 labeled GD2 monoclonal antibody in the diagnosis and therapy of human neuroblastoma

    International Nuclear Information System (INIS)

    Cheung, N.K.V.; Miraldi, F.D.

    1988-01-01

    High dose marrow ablative therapy followed by autologous bone marrow transplantation (ABMT) has prolonged survival in patients with neuroblastoma. Total body and focal irradiation play an integral role in the overall treatment of this disease. The biological basis for radiation is the radiosensitivity and the lack of sublethal repair in neuroblastoma cells. However, radiation therapy has not by itself been adequate because of the usual widespread nature of neuroblastoma and the inability to achieve selective tumor versus normal tissue delivery, especially at multiple tumor sites. Monoclonal antibodies are agents selected for their specificity for human tumors. In vivo they have the ability of targeting selectively to occult metastases. This paper discusses how the availability of radioisotopes and the development of conjugation chemistries have greatly expanded the potentials of these antibodies

  12. Scintigraphic imaging and turnover studies with iodine-131 labelled serum amyloid P component in systemic amyloidosis

    Energy Technology Data Exchange (ETDEWEB)

    Hawkins, P.N.; Pepys, M.B. [Immunological Medicine Unit, Department of Medicine, Royal Postgraduate Medical School, London (United Kingdom); Aprile, C. [Nuclear Medicine Service, Scientific Institute Fondazione Maugeri, Pavia (Italy); Capri, G.; Vigano, L.; Munzone, E.; Gianni, L. [Division of Medical Oncology, Istituto Nazionale Tumori, Milan (Italy); Merlini, G. [Biotechnology Research Laboratories, University Hospital S. Matteo, Pavia (Italy)

    1998-07-01

    Radiolabelled serum amyloid P component (SAP) is a specific tracer for amyloid. Iodine-123 has ideal physical characteristics for scintigraphy but is expensive and not widely available. Here we report serial imaging and turnover studies in which we labelled SAP with iodine-131, a cheap alternative isotope which would be expected to yield poorer images but permit more prolonged turnover measurements. Imaging and plasma clearance and whole body retention (WBR) of tracer were studied for up to 7 days in ten patients with proven systemic AL amyloidosis and two patients in whom the diagnosis was suspected, after i.v. administration of about 37 MBq of {sup 131}I-SAP. Normal blood pool images were obtained in the latter two subjects and amyloidosis was subsequently refuted histologically. WBR at 48 h was <60% and 6-h plasma activity was >65% of the injected dose (i.d.). Among the other ten patients, amyloid deposits were identified in the spleen in eight cases, liver in five and kidneys in four; other sites that gave positive results included bone, joints and soft tissues, and the myocardium in one case. Up to 95% of the tracer localised into amyloid within 6-h, and the values for WBR became progressively more discriminating during the study period, exceeding the normal reference value (<25%) in all cases by day 7. The optimal imaging time was found to be between 24 and 48 h. The duration of the study enabled us to measure the tracer elimination half-life which was increased in all cases by up to tenfold. Follow-up studies performed after 2-24 months in four patients who were treated with iododoxorubicin showed regression of amyloid in one patient and a small increase in one case; in the other two patients the imaging and turnover studies were identical to baseline. Despite its unfavourable imaging characteristics, {sup 131}I-SAP produced diagnostic scans in every patient in this series and, coupled with the detailed turnover information, is adequate for monitoring disease progress. (orig.) With 5 figs., 2 tabs., 19 refs.

  13. Kinetics of Iodine 131 labelled fibrinogen in cancerous patients. Pharmacological study

    International Nuclear Information System (INIS)

    Boneu-Valmalette, Andree; Bugat, Roland; David, J.-F.; Combes, P.-F.

    1977-01-01

    The results obtained in a previous study using 131 I fibrinogen in cancerous patients suggested a local intravascular clotting process. In order to elucidate the mechanism of fibrinogen kinetic abnormalities different drugs including heparin, prednisone, ticlopidin, aspirin and indomethacin were administred in 68 patients and their effects evaluated by change in the 131 I fibrinogen disappearance rate. The results suggest that these drugs may counteract with the early stages of coagulation (kinin-forming system, factor XII) and that abnormal 131 I fibrinogen kinetic in cancer would be a non specific phenomenon [fr

  14. The clearance of liposomes administered by the intramuscular route

    International Nuclear Information System (INIS)

    Arrowsmith, M.; Mills, S.N.

    1982-01-01

    Iodine 131-labelled lecithin was used to label liposomes entrapping cortisone-21-palmitate. The lecithin was injected into the fascia latae muscles of rabbits and the percentage of the initial dose remaining at certain time intervals was calculated from gamma camera image data. Release from the intramuscular site occurs by diffusion from intact liposomes. (U.K.)

  15. Cavities

    Science.gov (United States)

    ... mother's bacteria from being passed to the child. Treatment of Cavities Fluoride Fillings Root canal or tooth extraction If ... to help the world be well. From developing new therapies that treat and prevent disease to helping people ...

  16. Cavities

    Science.gov (United States)

    ... Additional Content Medical News Cavities ˈkav-ət-ē (Dental Caries) By James T. Ubertalli, DMD, Private Practice, Hingham, ... access to dental care, and better treatment for tooth decay and periodontal disease. When teeth are lost, chewing is greatly hindered, and speaking ...

  17. Targeted radionuclide therapy for lung cancer with iodine-131-labeled peptide in a nude-mouse model.

    Science.gov (United States)

    Chen, Zhenzhu; Gao, Hongyi; Li, Man; Fang, Shun; Li, Guiping; Guo, Linlang

    2017-06-01

    Integrin α3β1 has been shown to be a novel candidate target for the imaging and specific therapy of non-small-cell lung cancer. We have previously reported on a peptide containing a novel motif of NGXG that specifically binds to the integrin α3 receptor on lung cancer cells using a one-bead one-peptide combinatorial library. In this study, we developed the peptide cNGEGQQc-based therapeutic agent labeling with radionuclide iodine-131 (I) and evaluated its characteristics including stability, biodistribution, antitumor activity, and safety. The results showed that I-cNGEGQQc was stable in serum. Furthermore, the biodistribution of I-cNGEGQQc was determined in normal mice and rabbits. In-vivo biodistribution studies showed that radiolabeled peptide in the kidney was significantly higher than that in other organs. Nude mice bearing lung cancer cell xenografts (H1975 and L78) were used as an in-vivo model for tumor-inhibition efficacy studies with I-cNGEGQQc. The tumor growth decreased significantly in mice receiving I-labeled peptide compared with the controls and the effect of I-labeled peptide can be blocked by unlabeled cNGEGQQc. Safety studies showed that I-cNGEGQQc was relatively safe for animals without significant toxicity. Our data suggest that I-cNGEGQQc has potential as a targeted radiotherapeutic agent for non-small-cell lung cancer.

  18. Bispecific antibody and iodine-131-labeled bivalent hapten dosimetry in patients with medullary thyroid or small-cell lung cancer.

    Science.gov (United States)

    Bardiès, M; Bardet, S; Faivre-Chauvet, A; Peltier, P; Douillard, J Y; Mahé, M; Fiche, M; Lisbona, A; Giacalone, F; Meyer, P; Gautherot, E; Rouvier, E; Barbet, J; Chatal, J F

    1996-11-01

    The purpose of this study was to estimate the dose delivered to tumor targets and normal tissues after two-step injection of an anti-CEA/anti-DTPA-In (F6-734) bispecific antibody and a 131I-labeled di-DTPA in-TL bivalent hapten in patients with medullary thyroid carcinoma (MTC) and small-cell lung cancer (SCLC). Five patients with persistent disease or recurrences of MTC and five patients with primary SCLC or relapse were studied. In a first step, 0.1 to 0.3 mg/kg of F6-734 bispecific antibody was injected intravenously. Four days later, 6 nmole (5.8 to 9.8 mCi) of 131I-labeled di-DTPA in-TL bivalent hapten were injected. Quantitative imaging was performed during one week after the second injection. All 5 patients with MTC showed positive immunoscintigraphy (IS). In the smallest visualized and resected tumor (0.8 g), the fraction of injected activity per gram (% ID/g) was 0.1% at Day 3. IS was positive in 4 of the 5 patients with SCLC. The volume of the smallest visualized SCLC tumor was estimated at 11 +/- 2 ml, and tumor uptake was about 0.009% ID/g. Tumor dose estimates ranged from 4.2 to 174 cGy/mCi in patients with MTC and from 1.7 to 8 cGy/mCi in patients with SCLC. High absorbed dose values were calculated for small MTC recurrences. For SCLC recurrences the values were smaller but in the same range as those obtained by other investigators with the one-step technique in lymphoma.

  19. Efficacy and safety of selenium nanoparticles administered intraperitoneally for the prevention of growth of cancer cells in the peritoneal cavity.

    Science.gov (United States)

    Wang, Xin; Sun, Kang; Tan, Yanping; Wu, Shanshan; Zhang, Jinsong

    2014-07-01

    Peritoneal implantation of cancer cells, particularly postoperative seeding metastasis, frequently occurs in patients with primary tumors in the stomach, colon, liver, and ovary. Peritoneal carcinomatosis is associated with poor prognosis. In this work, we evaluated the prophylactic effect of intraperitoneal administration of selenium (Se), an essential trace element and a putative chemopreventive agent, on peritoneal implantation of cancer cells. Elemental Se nanoparticles were injected into the abdominal cavity of mice, into which highly malignant H22 hepatocarcinoma cells had previously been inoculated. Se concentrations in the cancer cells and tissues, as well as the efficacy of proliferation inhibition and safety, were evaluated. Se was mainly concentrated in cancer cells compared to Se retention in normal tissues, showing at least an order of magnitude difference between the drug target cells (the H22 cells) and the well-recognized toxicity target of Se (the liver). Such a favorable selective distribution resulted in strong proliferation suppression without perceived host toxicity. The mechanism of action of the Se nanoparticle-triggered cytotoxicity was associated with Se-mediated production of reactive oxygen species, which impaired the glutathione and thioredoxin systems. Our results suggest that intraperitoneal administration of Se is a safe and effective means of preventing growth of cancer cells in the peritoneal cavity for the above-mentioned high-risk populations. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Follow-up of relapsed B-cell lymphoma patients treated with iodine-131-labeled anti-CD20 antibody and autologous stem-cell rescue

    International Nuclear Information System (INIS)

    Liu, S Y.; Eary, Janet F.; Petersdorf, S H.; Martin, P J.; Maloney, D G.; Applebaum, F. R.; Matthews, D. C.; Bush, S A.; Durack, L. D.; Fisher, Darrell R.; Gooley, T A.; Bernstein, I. D.; Press, O. W.

    1997-01-01

    Radioimmunotherapy (RIT) is a promising treatment approach for B-cell lymphomas. This is our first opportunity to report long-term follow-up data and late toxicities in 29 patients treated with myeloablative doses of iodine-131-anti-CD20 antibody (anti-B1) and autologous stem-cell rescue. PATIENTS AND METHODS: Trace-labeled biodistribution studies first determined the ability to deliver higher absorbed radiation doses to tumor sites than to lung, liver, or kidney at varying amounts of anti-B1 protein (0.35, 1.7, or 7 mg/kg). Twenty- nine patients received therapeutic infusions of single-agent (131)I- anti-B1, given at the protein dose found optimal in the biodistribution study, labeled with amounts of (131)I (280 to 785 mCi[10.4 to 29.0 GBq]) calculated to deliver specific absorbed radiation doses to the normal organs, followed by autologous stem-cell support. RESULTS: Major responses occurred in 25 patients (86%), with 23 complete responses (CRs; 79%). The nonhematopoietic do se-limiting toxicity was reversible cardiopulmonary insufficiency, which occurred in two patients at RIT doses that delivered > or = 27 Gy to the lungs. With a median follow-up time of 42 months, the estimated overall and progression-free survival rates are 68% and 42%, respectively. Currently, 14 of 29 patients remain in unmaintained remissions that range from 27+ to 87+ months after RIT. Late toxicities have been uncommon except for elevated thyroid-stimulating hormone (TSH) levels found in approximately 60% of the subjects. Two patients developed second malignancies, but none have developed myelodysplasia (MDS). CONCLUSION: Myeloablative (131)I-anti- B1 RIT is relatively well tolerated when given with autologous stem- cell support and often results in prolonged remission durations with few late toxicities

  1. Management of patient with hepatocellular carcinomas by in situ injection of iodine-131 labelled lipiodol solution (Lipiocis) in the Biophysics and Timone APHM University Hospital Central Service

    International Nuclear Information System (INIS)

    Sigrist, S.

    2008-01-01

    The aim of this work was to determine what are the prognosis factors in term of global expectation of life at patient receiving a treatment by Lipiocis, to estimate the tolerance at this treatment in order to choose patient which will be the best candidates to this treatment and to define more precisely the criteria of patient inclusion and follow-up. A study including 35 patient having received one or several Lipiocis injections between May 2003 and May 2007 has been carried out. The results of this study are given. Lipiocis seems to be a well tolerated treatment which has proved its efficiency. (O.M.)

  2. A phase II study of intraperitoneal radioimmunotherapy with iodine-131-labeled monoclonal antibody OC-125 in patients with residual ovarian carcinoma.

    Science.gov (United States)

    Mahé, M A; Fumoleau, P; Fabbro, M; Guastalla, J P; Faurous, P; Chauvot, P; Chetanoud, L; Classe, J M; Rouanet, P; Chatal, J F

    1999-10-01

    Standard treatment of advanced ovarian cancer is a combination of surgery and chemotherapy. Additional therapies using the i.p. route are considered as a potential means of improving the locoregional control rate. This Phase II study evaluated the efficacy of i.p. radioimmunotherapy (RIT) in patients with minimal residual ovarian adenocarcinoma after primary treatment with surgery and chemotherapy. Between February 1995 and March 1996, six patients with residual macroscopic (<5 mm) or microscopic disease as demonstrated by laparotomy and multiple biopsies received i.p. RIT. All had initial stage III epithelial carcinoma and were treated with debulking surgery and one line (four patients) or two lines (two patients) of chemotherapy. RIT was performed with 60 mg of OC 125 F(ab')2 monoclonal antibody labeled with 4.44 GBq (120 mCi) of 131I injected 5-10 days after the surgical procedure. Systematic laparoscopy or laparotomy with multiple biopsies performed 3 months after RIT in five patients (clinical progression was seen in one patient) showed no change in three patients and progression in two patients. Toxicity was mainly hematological, with grade III neutropenia and thrombocytopenia in two patients. Human antimouse antibody production was demonstrated in all six patients. This study showed little therapeutic benefit from i.p. RIT in patients with residual ovarian carcinoma.

  3. Reproducibility of image interpretation in immunoscintigraphy performed with indium-111- and iodine-131-labeled OC125 F(ab')2 antibody injected into the same patients

    International Nuclear Information System (INIS)

    Vuillez, J.P.; Peltier, P.; Mayer, J.C.; Dubois, F.; Chetanneau, A.; Fumoleau, P.; Bertrand, A.; Chatal, J.F.

    1991-01-01

    An important criterion for the clinical use of a new imaging technique is the correct reproducibility of interpretation. Forty-six paired immunoscintigraphic examinations were performed on 43 patients with suspected ovarian carcinoma recurrence using F(ab')2 fragments of OC125 antibody labeled first with indium-111 and then with iodine-131. Planar scintigraphy (PS) and emission computed tomography (ECT) images were interpreted blindly and separately by three observers, and reproducibility was evaluated by a kappa concordance index. Intra- and interobserver reproducibility were generally satisfactory (kappa values of 0.6 and 0.7, respectively). Binomial analysis of kappa values for ECT showed the superiority of indium-111 for intraobserver (p = 0.035) and interobserver (p = 0.0039) study. However, for PS there was no significant difference in reproducibility with the two radionuclides

  4. Biokinetic studies and scintigraphic imaging of human pancreatic carcinoma xenografts with iodine 131-labeled F(ab')2-fragments of monoclonal antibodies

    International Nuclear Information System (INIS)

    Senekowitsch, R.; Moellenstaedt, S.; Kriegel, H.; Baum, R.P.; Maul, F.D.; Hoer, G.; Wenisch, H.J.C.

    1985-01-01

    Biodistribution and tumor uptake of I-131 labeled F(ab') 2 -fragments of monoclonal antibodies to CA 125, CA 19-9 and CEA were investigated in nuce mice with human pancreatic carcinoma xenografts. To assess the immunological specificity of these antibody fragments their tumor uptake was compared with that of unspecific IgG F(ab') 2 . Additionally serum levels of CA 125 and CA 19-9 were determined in tumor bearing mice by radioimmunoassay and the expression of CA 125 and CA 19-9 in pancreatic carcinoma was demonstrated by immunhistochemicals studies. The rapid blood clearance of the antibody fragments leads to increasing tumor-to-blood ratios with time after injection for all antibody fragments. The highest ratios were found for OC 125 at all time points p.i., with mean values of 9.6 at 48 h p.i. and 11.8 at 96 h p.i. On scintigraphic images tumors with a weight of 100 mg could be localized between 24 and 48 h after injection of iodinated OC 125 F(ab') 2 . The serum levels of CA 125 and CA 19-9 were elevated only in some animals and no correlation between the antigen serum levels and the antigen expression in the tumor shown by immunhistochemical staining could be determined. (orig.) [de

  5. Hematological toxicity in radioimmunotherapy is predicted both by the computed absorbed whole body dose (cGy) and by the administered dose (mCi)

    International Nuclear Information System (INIS)

    Marquez, Sheri D.; Knox, Susan J.; Trisler, Kirk D.; Goris, Michael L.

    1997-01-01

    Purpose/Objective: Radioimmunotherapy (RIT) has yielded encouraging response rates in patients with recurrent non-Hodgkin's lymphoma, but myelotoxicity remains the dose limiting factor. Dose optimization is theoretically possible, since a pretreatment biodistribution study with tracer doses allows for a fairly accurate estimate of the whole body (and by implication the bone marrow) dose in patients. It has been shown that the radiation dose as a function of the administered dose varies widely from patient to patient. The pretreatment study could therefore be used to determine the maximum tolerable dose for each individual patient. The purpose of this study was to examine whether the administered dose or the estimated whole body absorbed radiation dose were indeed predictors of bone marrow toxicity. Materials and Methods: We studied two cohorts of patients to determine if the computed integral whole body or marrow dose is predictive of myelotoxicity. The first cohort consisted of 13 patients treated with Yttrium-90 labeled anti-CD20 (2B8) monoclonal antibody. Those patients were treated in a dose escalation protocol, based on the administered dose, without correction for weight or body surface. The computed whole body dose varied from 41 to 129 cGy. The second cohort (6 patients) were treated with Iodine-131 labeled anti-CD20 (B1) antibody. In this group the administered dose was tailored to deliver an estimated 75 cGy whole body dose. The administered dose varied from 54 to 84 mCi of Iodine-131. For each patient, white blood cell count with differential, hemoglobin, hematocrit, and platelet levels were measured before and at regular intervals after RIT was administered. Using linear regression analysis, a relationship between administered dose, absorbed dose and myelotoxicity was determined for each patient cohort. Results: Marrow toxicity was measured by the absolute decrease in white blood cell (DWBC), platelet (DPLAT), and neutrophil (DN) values. In the Yttrium

  6. Dental cavities

    Science.gov (United States)

    ... acids in plaque damage the enamel covering your teeth. It also creates holes in the tooth called cavities. Cavities usually do not hurt, unless they grow very large and affect nerves or cause a tooth fracture. An untreated cavity can lead to an infection ...

  7. Cavity-cavity conditional logic

    Science.gov (United States)

    Rosenblum, Serge; Gao, Yvonne Y.; Reinhold, Philip; Wang, Chen; Axline, Christopher; Frunzio, Luigi; Girvin, Steven M.; Jiang, Liang; Mirrahimi, Mazyar; Devoret, Michel H.; Schoelkopf, Robert J.

    In a superconducting circuit architecture, the highest coherence times are typically offered by 3D cavities. Moreover, these cavities offer a hardware-efficient way of redundantly encoding quantum information. While single-qubit control on a cavity has already been demonstrated, there is a need for a universal two-qubit gate between such cavities. In this talk, we demonstrate a cavity-cavity gate by parametric pumping on a fixed-frequency transmon interacting with the two cavities. Every gate application lowers the state fidelity by only 1%, while maintaining an entangling rate on-off ratio of 29dB. Additionally, we show that the gate is applicable not only to qubits consisting of single photons, but also to more complex encodings. These results illustrate the usefulness of cavities beyond the mere storage of quantum information, and pave the way towards gates between error-corrected logical qubits.

  8. Iodine-131-labeled MAb F(ab')2 fragments are more efficient and less toxic than intact anti-CEA antibodies in radioimmunotherapy of large human colon carcinoma grafted in nude mice

    International Nuclear Information System (INIS)

    Buchegger, F.; Pelegrin, A.; Delaloye, B.; Bischof-Delaloye, A.; Mach, J.P.

    1990-01-01

    During one week, beginning 18 days after transplantation, nude mice bearing human colon carcinoma ranging from 115 to 943 mm3 (mean 335 mm3) were treated by repeated intravenous injections of either iodine-131-( 131 I) labeled intact antibodies or 131 I-labeled corresponding F(ab')2 fragments of a pool of four monoclonal antibodies (MAbs) directed against distinct epitopes of carcinoembryonic antigen (CEA). Complete tumor remission was observed in 8 of 10 mice after therapy with F(ab')2 and 6 of the animals survived 10 mo in good health. In contrast, after treatment with intact MAbs, tumors relapsed in 7 of 8 mice after remission periods of 1 to 3.5 mo despite the fact that body weight loss and depression of peripheral white blood cells, symptoms of radiation toxicity, and the calculated radiation doses for liver, spleen, bone, and blood were increased or equal in these animals as compared to mice treated with F(ab')2

  9. Cavity types

    CERN Document Server

    Gerigk, Frank

    2011-01-01

    In the field of particle accelerators the most common use of RF cavities is to increase the particle velocity of traversing particles. This feature makes them one of the core ingredients of every accelerator, and in the case of linear accelerators they are even the dominant machine component. Since there are many different types of accelerator, RF cavities have been optimized for different purposes and with different abilities, e.g., cavities with fixed or variable RF frequency, cavities for short or long pulses/CW operation, superconducting and normal-conducting cavities. This lecture starts with a brief historical introduction and an explanation on how to get from Maxwell's equations to a simple cavity. Then, cavities will be classified by the type of mode that is employed for acceleration, and an explanation is given as to why certain modes are used in particular cavity types. The lecture will close with a comparison of normal versus superconducting cavities and a few words on the actual power consumption ...

  10. accelerating cavity

    CERN Multimedia

    On the inside of the cavity there is a layer of niobium. Operating at 4.2 degrees above absolute zero, the niobium is superconducting and carries an accelerating field of 6 million volts per metre with negligible losses. Each cavity has a surface of 6 m2. The niobium layer is only 1.2 microns thick, ten times thinner than a hair. Such a large area had never been coated to such a high accuracy. A speck of dust could ruin the performance of the whole cavity so the work had to be done in an extremely clean environment.

  11. radiofrequency cavity

    CERN Multimedia

    1988-01-01

    The pulse of a particle accelerator. 128 of these radio frequency cavities were positioned around CERN's 27-kilometre LEP ring to accelerate electrons and positrons. The acceleration was produced by microwave electric oscillations at 352 MHz. The electrons and positrons were grouped into bunches, like beads on a string, and the copper sphere at the top stored the microwave energy between the passage of individual bunches. This made for valuable energy savings as it reduced the heat generated in the cavity.

  12. Cavity Optomechanics

    OpenAIRE

    Kippenberg, T. J.; Vahala, K. J.

    2007-01-01

    The coupling of mechanical and optical degrees of freedom via radiation pressure has been a subject of early research in the context of gravitational wave detection. Recent experimental advances have allowed studying for the first time the modifications of mechanical dynamics provided by radiation pressure. This paper reviews the consequences of back-action of light confined in whispering-gallery dielectric micro-cavities, and presents a unified treatment of its two manifestations: notably th...

  13. Segmented trapped vortex cavity

    Science.gov (United States)

    Grammel, Jr., Leonard Paul (Inventor); Pennekamp, David Lance (Inventor); Winslow, Jr., Ralph Henry (Inventor)

    2010-01-01

    An annular trapped vortex cavity assembly segment comprising includes a cavity forward wall, a cavity aft wall, and a cavity radially outer wall there between defining a cavity segment therein. A cavity opening extends between the forward and aft walls at a radially inner end of the assembly segment. Radially spaced apart pluralities of air injection first and second holes extend through the forward and aft walls respectively. The segment may include first and second expansion joint features at distal first and second ends respectively of the segment. The segment may include a forward subcomponent including the cavity forward wall attached to an aft subcomponent including the cavity aft wall. The forward and aft subcomponents include forward and aft portions of the cavity radially outer wall respectively. A ring of the segments may be circumferentially disposed about an axis to form an annular segmented vortex cavity assembly.

  14. The LHC superconducting cavities

    CERN Document Server

    Boussard, Daniel; Häbel, E; Kindermann, H P; Losito, R; Marque, S; Rödel, V; Stirbet, M

    1999-01-01

    The LHC RF system, which must handle high intensity (0.5 A d.c.) beams, makes use of superconducting single-cell cavities, best suited to minimizing the effects of periodic transient beam loading. There will be eight cavities per beam, each capable of delivering 2 MV (5 MV/m accelerating field) at 400 MHz. The cavities themselves are now being manufactured by industry, using niobium-on-copper technology which gives full satisfaction at LEP. A cavity unit includes a helium tank (4.5 K operating temperature) built around a cavity cell, RF and HOM couplers and a mechanical tuner, all housed in a modular cryostat. Four-unit modules are ultimately foreseen for the LHC (two per beam), while at present a prototype version with two complete units is being extensively tested. In addition to a detailed description of the cavity and its ancillary equipment, the first test results of the prototype will be reported.

  15. LEP copper accelerating cavities

    CERN Multimedia

    Laurent Guiraud

    1999-01-01

    These copper cavities were used to generate the radio frequency electric field that was used to accelerate electrons and positrons around the 27-km Large Electron-Positron (LEP) collider at CERN, which ran from 1989 to 2000. The copper cavities were gradually replaced from 1996 with new superconducting cavities allowing the collision energy to rise from 90 GeV to 200 GeV by mid-1999.

  16. Superconducting cavities for LEP

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    Above: a 350 MHz superconducting accelerating cavity in niobium of the type envisaged for accelerating electrons and positrons in later phases of LEP. Below: a small 1 GHz cavity used for investigating the surface problems of superconducting niobium. Albert Insomby stays on the right. See Annual Report 1983 p. 51.

  17. SPS RF Cavity

    CERN Multimedia

    1975-01-01

    The picture shows one of the two initially installed cavities. The main RF-system of the SPS comprises four cavities: two of 20 m length and two of 16.5 m length. They are all installed in one long straight section (LSS 3). These cavities are of the travelling-wave type operating at a centre frequency of 200.2 MHz. They are wideband, filling time about 700 ns and untuned. The power amplifiers, using tetrodes are installed in a surface building 200 m from the cavities. Initially only two cavities were installed, a third cavity was installed in 1978 and a forth one in 1979. The number of power amplifiers was also gradually increased: by end 1980 there were 8 500 kW units combined in pairs to feed each of the 4 cavities with up to about 1 MW RF power, resulting in a total accelerating voltage of about 8 MV. See also 7412017X, 7411048X, 7505074.

  18. SPS RF Accelerating Cavity

    CERN Multimedia

    1979-01-01

    This picture shows one of the 2 new cavities installed in 1978-1979. The main RF-system of the SPS comprises four cavities: two of 20 m length and two of 16.5 m length. They are all installed in one long straight section (LSS 3). These cavities are of the travelling-wave type operating at a centre frequency of 200.2 MHz. They are wideband, filling time about 700 ns and untuned. The power amplifiers, using tetrodes are installed in a surface building 200 m from the cavities. Initially only two cavities were installed, a third cavity was installed in 1978 and a forth one in 1979. The number of power amplifiers was also increased: to the first 2 MW plant a second 2 MW plant was added and by end 1979 there were 8 500 kW units combined in pairs to feed each of the 4 cavities with up to about 1 MW RF power, resulting in a total accelerating voltage of about 8 MV. See also 7412016X, 7412017X, 7411048X

  19. Superconducting TESLA cavities

    Directory of Open Access Journals (Sweden)

    B. Aune

    2000-09-01

    Full Text Available The conceptional design of the proposed linear electron-positron collider TESLA is based on 9-cell 1.3 GHz superconducting niobium cavities with an accelerating gradient of E_{acc}≥25 MV/m at a quality factor Q_{0}≥5×10^{9}. The design goal for the cavities of the TESLA Test Facility (TTF linac was set to the more moderate value of E_{acc}≥15 MV/m. In a first series of 27 industrially produced TTF cavities the average gradient at Q_{0}=5×10^{9} was measured to be 20.1±6.2 MV/m, excluding a few cavities suffering from serious fabrication or material defects. In the second production of 24 TTF cavities, additional quality control measures were introduced, in particular, an eddy-current scan to eliminate niobium sheets with foreign material inclusions and stringent prescriptions for carrying out the electron-beam welds. The average gradient of these cavities at Q_{0}=5×10^{9} amounts to 25.0±3.2 MV/m with the exception of one cavity suffering from a weld defect. Hence only a moderate improvement in production and preparation techniques will be needed to meet the ambitious TESLA goal with an adequate safety margin. In this paper we present a detailed description of the design, fabrication, and preparation of the TESLA Test Facility cavities and their associated components and report on cavity performance in test cryostats and with electron beam in the TTF linac. The ongoing research and development towards higher gradients is briefly addressed.

  20. Hydroforming of elliptical cavities

    Directory of Open Access Journals (Sweden)

    W. Singer

    2015-02-01

    Full Text Available Activities of the past several years in developing the technique of forming seamless (weldless cavity cells by hydroforming are summarized. An overview of the technique developed at DESY for the fabrication of single cells and multicells of the TESLA cavity shape is given and the major rf results are presented. The forming is performed by expanding a seamless tube with internal water pressure while simultaneously swaging it axially. Prior to the expansion the tube is necked at the iris area and at the ends. Tube radii and axial displacements are computer controlled during the forming process in accordance with results of finite element method simulations for necking and expansion using the experimentally obtained strain-stress relationship of tube material. In cooperation with industry different methods of niobium seamless tube production have been explored. The most appropriate and successful method is a combination of spinning or deep drawing with flow forming. Several single-cell niobium cavities of the 1.3 GHz TESLA shape were produced by hydroforming. They reached accelerating gradients E_{acc} up to 35  MV/m after buffered chemical polishing (BCP and up to 42  MV/m after electropolishing (EP. More recent work concentrated on fabrication and testing of multicell and nine-cell cavities. Several seamless two- and three-cell units were explored. Accelerating gradients E_{acc} of 30–35  MV/m were measured after BCP and E_{acc} up to 40  MV/m were reached after EP. Nine-cell niobium cavities combining three three-cell units were completed at the company E. Zanon. These cavities reached accelerating gradients of E_{acc}=30–35  MV/m. One cavity is successfully integrated in an XFEL cryomodule and is used in the operation of the FLASH linear accelerator at DESY. Additionally the fabrication of bimetallic single-cell and multicell NbCu cavities by hydroforming was successfully developed. Several NbCu clad single-cell and

  1. Multicolor cavity soliton.

    Science.gov (United States)

    Luo, Rui; Liang, Hanxiao; Lin, Qiang

    2016-07-25

    We show a new class of complex solitary wave that exists in a nonlinear optical cavity with appropriate dispersion characteristics. The cavity soliton consists of multiple soliton-like spectro-temporal components that exhibit distinctive colors but coincide in time and share a common phase, formed together via strong inter-soliton four-wave mixing and Cherenkov radiation. The multicolor cavity soliton shows intriguing spectral locking characteristics and remarkable capability of spectrum management to tailor soliton frequencies, which would be very useful for versatile generation and manipulation of multi-octave spanning phase-locked Kerr frequency combs, with great potential for applications in frequency metrology, optical frequency synthesis, and spectroscopy.

  2. Cavity-enhanced spectroscopies

    CERN Document Server

    van Zee, Roger

    2003-01-01

    ""Cavity-Enhanced Spectroscopy"" discusses the use of optical resonators and lasers to make sensitive spectroscopic measurements. This volume is written by the researcchers who pioneered these methods. The book reviews both the theory and practice behind these spectroscopic tools and discusses the scientific discoveries uncovered by these techniques. It begins with a chapter on the use of optical resonators for frequency stabilization of lasers, which is followed by in-depth chapters discussing cavity ring-down spectroscopy, frequency-modulated, cavity-enhanced spectroscopy, intracavity spectr

  3. Tuned optical cavity magnetometer

    Science.gov (United States)

    Okandan, Murat; Schwindt, Peter

    2010-11-02

    An atomic magnetometer is disclosed which utilizes an optical cavity formed from a grating and a mirror, with a vapor cell containing an alkali metal vapor located inside the optical cavity. Lasers are used to magnetically polarize the alkali metal vapor and to probe the vapor and generate a diffracted laser beam which can be used to sense a magnetic field. Electrostatic actuators can be used in the magnetometer for positioning of the mirror, or for modulation thereof. Another optical cavity can also be formed from the mirror and a second grating for sensing, adjusting, or stabilizing the position of the mirror.

  4. accelerating cavity from LEP

    CERN Multimedia

    This is an accelerating cavity from LEP, with a layer of niobium on the inside. Operating at 4.2 degrees above absolute zero, the niobium is superconducting and carries an accelerating field of 6 million volts per metre with negligible losses. Each cavity has a surface of 6 m2. The niobium layer is only 1.2 microns thick, ten times thinner than a hair. Such a large area had never been coated to such a high accuracy. A speck of dust could ruin the performance of the whole cavity so the work had to be done in an extremely clean environment. These challenging requirements pushed European industry to new achievements. 256 of these cavities are now used in LEP to double the energy of the particle beams.

  5. SPS accelerating cavity

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    The SPS started up with 2 accelerating cavities (each consisting of 5 tank sections) in LSS3. They have a 200 MHz travelling wave structure (see 7411032 and 7802190) and 750 kW of power is fed to each of the cavities from a 1 MW tetrode power amplifier, located in a surface building above, via a coaxial transmission line. Clemens Zettler, builder of the SPS RF system, is standing at the side of one of the cavities. In 1978 and 1979 another 2 cavities were added and entered service in 1980. These were part of the intensity improvement programme and served well for the new role of the SPS as proton-antiproton collider. See also 7411032, 8011289, 8104138, 8302397.

  6. Hybrid vertical cavity laser

    DEFF Research Database (Denmark)

    Chung, Il-Sug; Mørk, Jesper

    2010-01-01

    A new hybrid vertical cavity laser structure for silicon photonics is suggested and numerically investigated. It incorporates a silicon subwavelength grating as a mirror and a lateral output coupler to a silicon ridge waveguide.......A new hybrid vertical cavity laser structure for silicon photonics is suggested and numerically investigated. It incorporates a silicon subwavelength grating as a mirror and a lateral output coupler to a silicon ridge waveguide....

  7. The Superconducting TESLA Cavities

    CERN Document Server

    Aune, B.; Bloess, D.; Bonin, B.; Bosotti, A.; Champion, M.; Crawford, C.; Deppe, G.; Dwersteg, B.; Edwards, D.A.; Edwards, H.T.; Ferrario, M.; Fouaidy, M.; Gall, P-D.; Gamp, A.; Gössel, A.; Graber, J.; Hubert, D.; Hüning, M.; Juillard, M.; Junquera, T.; Kaiser, H.; Kreps, G.; Kuchnir, M.; Lange, R.; Leenen, M.; Liepe, M.; Lilje, L.; Matheisen, A.; Möller, W-D.; Mosnier, A.; Padamsee, H.; Pagani, C.; Pekeler, M.; Peters, H-B.; Peters, O.; Proch, D.; Rehlich, K.; Reschke, D.; Safa, H.; Schilcher, T.; Schmüser, P.; Sekutowicz, J.; Simrock, S.; Singer, W.; Tigner, M.; Trines, D.; Twarowski, K.; Weichert, G.; Weisend, J.; Wojtkiewicz, J.; Wolff, S.; Zapfe, K.

    2000-01-01

    The conceptional design of the proposed linear electron-positron colliderTESLA is based on 9-cell 1.3 GHz superconducting niobium cavities with anaccelerating gradient of Eacc >= 25 MV/m at a quality factor Q0 > 5E+9. Thedesign goal for the cavities of the TESLA Test Facility (TTF) linac was set tothe more moderate value of Eacc >= 15 MV/m. In a first series of 27industrially produced TTF cavities the average gradient at Q0 = 5E+9 wasmeasured to be 20.1 +- 6.2 MV/m, excluding a few cavities suffering fromserious fabrication or material defects. In the second production of 24 TTFcavities additional quality control measures were introduced, in particular aneddy-current scan to eliminate niobium sheets with foreign material inclusionsand stringent prescriptions for carrying out the electron-beam welds. Theaverage gradient of these cavities at Q0 = 5E+9 amounts to 25.0 +- 3.2 MV/mwith the exception of one cavity suffering from a weld defect. Hence only amoderate improvement in production and preparation technique...

  8. Materials for superconducting cavities

    International Nuclear Information System (INIS)

    Bonin, B.

    1996-01-01

    The ideal material for superconducting cavities should exhibit a high critical temperature, a high critical field, and, above all, a low surface resistance. Unfortunately, these requirements can be conflicting and a compromise has to be found. To date, most superconducting cavities for accelerators are made of niobium. The reasons for this choice are discussed. Thin films of other materials such as NbN, Nb 3 Sn, or even YBCO compounds can also be envisaged and are presently investigated in various laboratories. It is shown that their success will depend critically on the crystalline perfection of these films. (author)

  9. Experimental investigation of cavity flows

    Energy Technology Data Exchange (ETDEWEB)

    Loeland, Tore

    1998-12-31

    This thesis uses LDV (Laser Doppler Velocimetry), PIV (Particle Image Velocimetry) and Laser Sheet flow Visualisation to study flow inside three different cavity configurations. For sloping cavities, the vortex structure inside the cavities is found to depend upon the flow direction past the cavity. The shape of the downstream corner is a key factor in destroying the boundary layer flow entering the cavity. The experimental results agree well with numerical simulations of the same geometrical configurations. The results of the investigations are used to find the influence of the cavity flow on the accuracy of the ultrasonic flowmeter. A method to compensate for the cavity velocities is suggested. It is found that the relative deviation caused by the cavity velocities depend linearly on the pipe flow. It appears that the flow inside the cavities should not be neglected as done in the draft for the ISO technical report on ultrasonic flowmeters. 58 refs., 147 figs., 2 tabs.

  10. Should Pharmacy Technicians Administer Immunizations?

    Directory of Open Access Journals (Sweden)

    Dylan Atkinson

    2017-09-01

    Full Text Available Purpose. To describe the potential role for pharmacy technicians in administering immunizations – limited for this discussion to specifically inserting the needle into the patient’s arm and pressing down on the plunger – at the discretion of a supervising pharmacist as a way to enhance patient care and workflow efficiency. Summary. Pharmacy technicians currently play an important role in facilitating pharmacy-based immunization programs. Technicians routinely perform non-clinical tasks related to pharmacy-based immunizations, though nearly all states prohibit technicians from administering vaccines. Several studies demonstrate that untrained laypersons can safely administer intranasal or intradermal vaccines, and laypersons routinely administer medications through intramuscular or subcutaneous routes (e.g., patients with diabetes or rheumatic conditions. It stands to reason that a trained pharmacy technician could perform comparably on these techniques that laypersons have mastered. One state has adopted rules to allow pharmacy technicians to administer immunizations if the technician has completed specific training on administration techniques and on basic life support. This task is performed at the discretion of the supervising pharmacist, and the pharmacist would still be responsible for clinical aspects of immunizing such as prescribing the right vaccine to the right patient. Additional considerations factoring into the decision as to whether or not to involve pharmacy technicians in immunization administration are also summarized. Conclusion. If safety can be reasonably assured through training and supervision, it may be appropriate to delegate vaccine administration to appropriately trained pharmacy technicians. Such delegation may enhance workflow efficiency, which may confer added value for patient care and potentially improve access to community pharmacy-based immunizations.   Type: Commentary

  11. Superconducting elliptical cavities

    CERN Document Server

    Sekutowicz, J K

    2011-01-01

    We give a brief overview of the history, state of the art, and future for elliptical superconducting cavities. Principles of the cell shape optimization, criteria for multi-cell structures design, HOM damping schemes and other features are discussed along with examples of superconducting structures for various applications.

  12. LEP superconducting cavity

    CERN Multimedia

    1995-01-01

    Engineers work in a clean room on one of the superconducting cavities for the upgrade to the LEP accelerator, known as LEP-2. The use of superconductors allow higher electric fields to be produced so that higher beam energies can be reached.

  13. Additive Manufactured Superconducting Cavities

    Science.gov (United States)

    Holland, Eric; Rosen, Yaniv; Woolleet, Nathan; Materise, Nicholas; Voisin, Thomas; Wang, Morris; Mireles, Jorge; Carosi, Gianpaolo; Dubois, Jonathan

    Superconducting radio frequency cavities provide an ultra-low dissipative environment, which has enabled fundamental investigations in quantum mechanics, materials properties, and the search for new particles in and beyond the standard model. However, resonator designs are constrained by limitations in conventional machining techniques. For example, current through a seam is a limiting factor in performance for many waveguide cavities. Development of highly reproducible methods for metallic parts through additive manufacturing, referred to colloquially as 3D printing\\x9D, opens the possibility for novel cavity designs which cannot be implemented through conventional methods. We present preliminary investigations of superconducting cavities made through a selective laser melting process, which compacts a granular powder via a high-power laser according to a digitally defined geometry. Initial work suggests that assuming a loss model and numerically optimizing a geometry to minimize dissipation results in modest improvements in device performance. Furthermore, a subset of titanium alloys, particularly, a titanium, aluminum, vanadium alloy (Ti - 6Al - 4V) exhibits properties indicative of a high kinetic inductance material. This work is supported by LDRD 16-SI-004.

  14. Niobium superconducting cavity

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    This 5-cell superconducting cavity, made from bulk-Nb, stems from the period of general studies, not all directed towards direct use at LEP. This one is dimensioned for 1.5 GHz, the frequency used at CEBAF and also studied at Saclay (LEP RF was 352.2 MHz). See also 7908227, 8007354, 8209255, 8210054, 8312339.

  15. What's a Cavity?

    Science.gov (United States)

    ... and deeper over time. Cavities are also called dental caries (say: KARE-eez), and if you have a ... made up mostly of the germs that cause tooth decay. The bacteria in your mouth make acids and when plaque clings to your teeth, the acids can eat away at the outermost ...

  16. Filling a Conical Cavity

    Science.gov (United States)

    Nye, Kyle; Eslam-Panah, Azar

    2016-11-01

    Root canal treatment involves the removal of infected tissue inside the tooth's canal system and filling the space with a dense sealing agent to prevent further infection. A good root canal treatment happens when the canals are filled homogeneously and tightly down to the root apex. Such a tooth is able to provide valuable service for an entire lifetime. However, there are some examples of poorly performed root canals where the anterior and posterior routes are not filled completely. Small packets of air can be trapped in narrow access cavities when restoring with resin composites. Such teeth can cause trouble even after many years and lead the conditions like acute bone infection or abscesses. In this study, the filling of dead-end conical cavities with various liquids is reported. The first case studies included conical cavity models with different angles and lengths to visualize the filling process. In this investigation, the rate and completeness at which a variety of liquids fill the cavity were observed to find ideal conditions for the process. Then, a 3D printed model of the scaled representation of a molar with prepared post spaces was used to simulate the root canal treatment. The results of this study can be used to gain a better understanding of the restoration for endodontically treated teeth.

  17. Changeability of Oral Cavity Environment

    OpenAIRE

    Surdacka, Anna; Strzyka?a, Krystyna; Rydzewska, Anna

    2007-01-01

    Objectives In dentistry, the results of in vivo studies on drugs, dental fillings or prostheses are routinely evaluated based on selected oral cavity environment parameters at specific time points. Such evaluation may be confounded by ongoing changes in the oral cavity environment induced by diet, drug use, stress and other factors. The study aimed to confirm oral cavity environment changeability. Methods 24 healthy individuals aged 20?30 had their oral cavity environment prepared by having p...

  18. Optimization of photonic crystal cavities

    DEFF Research Database (Denmark)

    Wang, Fengwen; Sigmund, Ole

    2017-01-01

    We present optimization of photonic crystal cavities. The optimization problem is formulated to maximize the Purcell factor of a photonic crystal cavity. Both topology optimization and air-hole-based shape optimization are utilized for the design process. Numerical results demonstrate...... that the Purcell factor of the photonic crystal cavity can be significantly improved through optimization....

  19. Single-cavity SLED device

    International Nuclear Information System (INIS)

    Lippmann, B.A.

    1984-09-01

    The conventional SLED device used at SLAC requires two cavities. However, the same effect can be obtained with a single cavity; the theory and operation of the device is the same, only the hardware is changed. The single-cavity device is described here

  20. Hollow waveguide cavity ringdown spectroscopy

    Science.gov (United States)

    Dreyer, Chris (Inventor); Mungas, Greg S. (Inventor)

    2012-01-01

    Laser light is confined in a hollow waveguide between two highly reflective mirrors. This waveguide cavity is used to conduct Cavity Ringdown Absorption Spectroscopy of loss mechanisms in the cavity including absorption or scattering by gases, liquid, solids, and/or optical elements.

  1. Colloquium: cavity optomechanics

    CERN Multimedia

    2011-01-01

    Monday 14 November 2011, 17:00 Ecole de Physique, Auditoire Stueckelberg Université de Genève Cavity optomechanics: controlling micro mechanical oscillators with laser light Prof. Tobias Kippenberg EPFL, Lausanne Laser light can be used to cool and to control trapped ions, atoms and molecules at the quantum level. This has lead to spectacular advances such as the most precise atomic clocks. An outstanding frontier is the control with lasers of nano- and micro-mechancial systems. Recent advances in cavity optomechanics have allowed such elementary control for the first time, enabling mechanical systems to be ground state cooled leading to readout with quantum limited sensitivity and permitting to explore new device concepts resulting from radiation pressure.  

  2. Digital Cavity Resonance Monitor, alternative method of measuring cavity microphonics

    International Nuclear Information System (INIS)

    Tomasz Plawski; G. Davis; Hai Dong; J. Hovater; John Musson; Thomas Powers

    2005-01-01

    As is well known, mechanical vibration or microphonics in a cryomodule causes the cavity resonance frequency to change at the vibration frequency. One way to measure the cavity microphonics is to drive the cavity with a Phase Locked Loop. Measurement of the instantaneous frequency or PLL error signal provides information about the cavity microphonic frequencies. Although the PLL error signal is available directly, precision frequency measurements require additional instrumentation, a Cavity Resonance Monitor (CRM). The analog version of such a device has been successfully used for several cavity tests [1]. In this paper we present a prototype of a Digital Cavity Resonance Monitor designed and built in the last year. The hardware of this instrument consists of an RF downconverter, digital quadrature demodulator and digital processor motherboard (Altera FPGA). The motherboard processes received data and computes frequency changes with a resolution of 0.2 Hz, with a 3 kHz output bandwidth

  3. Biodistribution of Intraperitoneally-administered {sup 125}I-labeled IgG in Mouse

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sooyong; Dho, So Hee; Cho, Eunha; Lee, Soyoung; Jung, Sunghee; Lim, Jaecheong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The use of radiolabeled antibodies is one of the most effective strategies to diagnose and treat cancers. However, it is hindered by the relatively low delivery to tumors following intravenous administration, in particular, cancers in peritoneal cavity. Intraperitoneal administration of radiolabeled antibodies results in significantly higher exposure to the peritoneal cavity than does intravenous administration. Therefore, intraperitoneal administration of the radiolabeled antibodies can be more effective to diagnose and treat cancers in peritoneal cavity such as ovarian and colonic cancers. This study was performed to determine the biodistribution pattern of intraperitoneally-administered radiolabeled antibodies. The {sup 125}I-labeled IgG was rapidly absorbed into the blood and organs, and the radioactivities were dropped in 24 hr p.i. These results suggest that the intraperitoneal administration of the radiolabeled antibodies can be an effective way to treat diseases in the peritoneal cavity.

  4. ISR RF cavities

    CERN Multimedia

    1983-01-01

    In each ISR ring the radiofrequency cavities were installed in one 9 m long straight section. The RF system of the ISR had the main purpose to stack buckets of particles (most of the time protons)coming from the CPS and also to accelerate the stacked beam. The installed RF power per ring was 18 kW giving a peak accelerating voltage of 20 kV. The system had a very fine regulation feature allowing to lower the voltage down to 75 V in a smooth and well controlled fashion.

  5. Oral cavity eumycetoma

    Directory of Open Access Journals (Sweden)

    Gisele Alborghetti Nai

    2011-06-01

    Full Text Available Mycetoma is a pathological process in which eumycotic (fungal or actinomycotic causative agents from exogenous source produce grains. It is a localized chronic and deforming infectious disease of subcutaneous tissue, skin and bones. We report the first case of eumycetoma of the oral cavity in world literature. CASE REPORT: A 43-year-old male patient, complaining of swelling and fistula in the hard palate. On examination, swelling of the anterior and middle hard palate, with fistula draining a dark liquid was observed. The panoramic radiograph showed extensive radiolucent area involving the region of teeth 21-26 and the computerized tomography showed communication with the nasal cavity, suggesting the diagnosis of periapical cyst. Surgery was performed to remove the lesion. Histopathological examination revealed purulent material with characteristic grain. Gram staining for bacteria was negative and Grocott-Gomori staining for the detection of fungi was positive, concluding the diagnosis of eumycetoma. The patient was treated with ketoconazole for nine months, and was considered cured at the end of treatment. CONCLUSION: Histopathological examination, using histochemical staining, and direct microscopic grains examination can provide the distinction between eumycetoma and actinomycetoma accurately.

  6. Development of large grain cavities

    Directory of Open Access Journals (Sweden)

    W. Singer

    2013-01-01

    Full Text Available DESY activities on 1.3 GHz tesla shape single cell and nine-cell large grain (LG resonators are presented; results of the past five years are covered. The R&D program explores the potential for production of elliptical superconducting cavities. The main efforts have been devoted to material investigation, development of LG disk production, cavity fabrication from this material, and a search for appropriate treatment. More than 250 LG disks are manufactured; several single cell and 11 nine-cell resonators are produced and rf tested after buffered chemical polishing and after additional electropolishing. A maximum accelerating gradient of approximately 45  MV/m for this type of cavity was achieved in two resonators. Two of the LG cavities have been installed and are currently being used in the FLASH accelerator operation. Assembly of a cryomodule, consisting of LG cavities only, is in the works. Perspectives of the LG cavity application are discussed.

  7. MEDICI reactor cavity model

    International Nuclear Information System (INIS)

    Bergeron, K.D.; Trebilcock, W.

    1983-01-01

    The MEDICI reactor cavity model is currently under development with the goal of providing a flexible, relatively realistic treatment of ex-vessel severe accident phenomena suitable for large-system codes like CONTAIN and MELCOR. The code is being developed with an emphasis on top-down design, to facilitate adaptability and multiple applications. A brief description of the overall code structure is provided. One of the key new models is then described in more detail. This is a dynamic quench model for debris beds. An example calculation using this model is presented. The question of whether it is necessary to consider the simultaneous motion of the quench front and ablation of the concrete is addressed with some scoping models

  8. Superconducting cavity model for LEP

    CERN Document Server

    CERN PhotoLab

    1979-01-01

    A superconducting cavity model is being prepared for testing in a vertical cryostat.At the top of the assembly jig is H.Preis while A.Scharding adjusts some diagnostic equipment to the cavity. See also photo 7912501X.

  9. Superconducting Storage Cavity for RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Zvi,I.

    2009-01-02

    This document provides a top-level description of a superconducting cavity designed to store hadron beams in the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory. It refers to more detailed documents covering the various issues in designing, constructing and operating this cavity. The superconducting storage cavity is designed to operate at a harmonic of the bunch frequency of RHIC at a relatively low frequency of 56 MHz. The current storage cavities of RHIC operate at 197 MHz and are normal-conducting. The use of a superconducting cavity allows for a high gap voltage, over 2 MV. The combination of a high voltage and low frequency provides various advantages stemming from the resulting large longitudinal acceptance bucket.

  10. Mechanical Properties of Niobium Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Ciovati, Gianluigi [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Dhakal, Pashupati [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Matalevich, Joseph R. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Myneni, Ganapati Rao [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2015-09-01

    The mechanical stability of bulk Nb cavity is an important aspect to be considered in relation to cavity material, geometry and treatments. Mechanical properties of Nb are typically obtained from uniaxial tensile tests of small samples. In this contribution we report the results of measurements of the resonant frequency and local strain along the contour of single-cell cavities made of ingot and fine-grain Nb of different purity subjected to increasing uniform differential pressure, up to 6 atm. Measurements have been done on cavities subjected to different heat treatments. Good agreement between finite element analysis simulations and experimental data in the elastic regime was obtained with a single set of values of Young’s modulus and Poisson’s ratio. The experimental results indicate that the yield strength of medium-purity ingot Nb cavities is higher than that of fine-grain, high-purity Nb.

  11. Changeability of oral cavity environment.

    Science.gov (United States)

    Surdacka, Anna; Strzyka A, Krystyna; Rydzewska, Anna

    2007-01-01

    In dentistry, the results of in vivo studies on drugs, dental fillings or prostheses are routinely evaluated based on selected oral cavity environment parameters at specific time points. Such evaluation may be confounded by ongoing changes in the oral cavity environment induced by diet, drug use, stress and other factors. The study aimed to confirm oral cavity environment changeability. 24 healthy individuals aged 20-30 had their oral cavity environment prepared by having professional hygiene procedures performed and caries lesions filled. Baseline examination and the examination two years afterwards, evaluated clinical and laboratory parameters of oral cavity environment. Caries incidence was determined based on DMFT and DMFS values, oral cavity hygiene on Plaque Index (acc. Silness & Loe) and Hygiene Index (acc. O'Leary), and the gingival status on Gingival Index (acc. Loe & Silness) and Gingival Bleeding Index (acc. Ainamo & Bay). Saliva osmolarity, pH and concentrations of Ca(2+), Pi, Na(+), Cl(-), total protein, albumins, F(-) and Sr(2+) were determined. The results confirmed ongoing changeability of the oral cavity environment. After 2 years of the study reduction in oral cavity hygiene parameters PLI and HI (P<0.1), and gingival indices as well as lower saliva concentration of Ca(2+) (P<.001), Pi (P<.06), K(+) (P<.04), Sr(2+) (P<.03), Na(+) (P<.1), against the baseline values, were observed. Total protein and albumin saliva concentrations were also significantly lower. Physiological oral cavity environment is subject to constant, individually different, changes which should be considered when analysing studies that employ oral cavity environment parameters.

  12. Nonlocal Intracranial Cavity Extraction

    Science.gov (United States)

    Manjón, José V.; Eskildsen, Simon F.; Coupé, Pierrick; Romero, José E.; Collins, D. Louis; Robles, Montserrat

    2014-01-01

    Automatic and accurate methods to estimate normalized regional brain volumes from MRI data are valuable tools which may help to obtain an objective diagnosis and followup of many neurological diseases. To estimate such regional brain volumes, the intracranial cavity volume (ICV) is often used for normalization. However, the high variability of brain shape and size due to normal intersubject variability, normal changes occurring over the lifespan, and abnormal changes due to disease makes the ICV estimation problem challenging. In this paper, we present a new approach to perform ICV extraction based on the use of a library of prelabeled brain images to capture the large variability of brain shapes. To this end, an improved nonlocal label fusion scheme based on BEaST technique is proposed to increase the accuracy of the ICV estimation. The proposed method is compared with recent state-of-the-art methods and the results demonstrate an improved performance both in terms of accuracy and reproducibility while maintaining a reduced computational burden. PMID:25328511

  13. Nonlocal Intracranial Cavity Extraction

    Directory of Open Access Journals (Sweden)

    José V. Manjón

    2014-01-01

    Full Text Available Automatic and accurate methods to estimate normalized regional brain volumes from MRI data are valuable tools which may help to obtain an objective diagnosis and followup of many neurological diseases. To estimate such regional brain volumes, the intracranial cavity volume (ICV is often used for normalization. However, the high variability of brain shape and size due to normal intersubject variability, normal changes occurring over the lifespan, and abnormal changes due to disease makes the ICV estimation problem challenging. In this paper, we present a new approach to perform ICV extraction based on the use of a library of prelabeled brain images to capture the large variability of brain shapes. To this end, an improved nonlocal label fusion scheme based on BEaST technique is proposed to increase the accuracy of the ICV estimation. The proposed method is compared with recent state-of-the-art methods and the results demonstrate an improved performance both in terms of accuracy and reproducibility while maintaining a reduced computational burden.

  14. Frequency-feedback cavity enhanced spectrometer

    Science.gov (United States)

    Hovde, David Christian; Gomez, Anthony

    2015-08-18

    A spectrometer comprising an optical cavity, a light source capable of producing light at one or more wavelengths transmitted by the cavity and with the light directed at the cavity, a detector and optics positioned to collect light transmitted by the cavity, feedback electronics causing oscillation of amplitude of the optical signal on the detector at a frequency that depends on cavity losses, and a sensor measuring the oscillation frequency to determine the cavity losses.

  15. Call for Papers: Cavity QED

    Science.gov (United States)

    Lange, W.; Gerard, J.-M.

    2003-06-01

    Cavity QED interactions of light and matter have been investigated in a wide range of systems covering the spectrum from microwaves to optical frequencies, using media as diverse as single atoms and semiconductors. Impressive progress has been achieved technologically as well as conceptually. This topical issue of Journal of Optics B: Quantum and Semiclassical Optics is intended to provide a comprehensive account of the current state of the art of cavity QED by uniting contributions from researchers active across this field. As Guest Editors of this topical issue, we invite manuscripts on current theoretical and experimental work on any aspects of cavity QED. The topics to be covered will include, but are not limited to: bulletCavity QED in optical microcavities bulletSemiconductor cavity QED bulletQuantum dot cavity QED bulletRydberg atoms in microwave cavities bulletPhotonic crystal cavity QED bulletMicrosphere resonators bulletMicrolasers and micromasers bulletMicrodroplets bulletDielectric cavity QED bulletCavity QED-based quantum information processing bulletQuantum state engineering in cavities The DEADLINE for submission of contributions is 31 July 2003 to allow the topical issue to appear in about February 2004. All papers will be peer-reviewed in accordance with the normal refereeing procedures and standards of Journal of Optics B: Quantum and Semiclassical Optics. Advice on publishing your work in the journal may be found at www.iop.org/journals/authors/jopb. Submissions should ideally be in either standard LaTeX form or Microsoft Word. There are no page charges for publication. In addition to the usual 50 free reprints, the corresponding author of each paper published will receive a complimentary copy of the topical issue. Contributions to the topical issue should if possible be submitted electronically at www.iop.org/journals/jopb. or by e-mail to jopb@iop.org. Authors unable to submit online or by e-mail may send hard copy contributions (enclosing the

  16. Bistability of Cavity Magnon Polaritons

    Science.gov (United States)

    Wang, Yi-Pu; Zhang, Guo-Qiang; Zhang, Dengke; Li, Tie-Fu; Hu, C.-M.; You, J. Q.

    2018-01-01

    We report the first observation of the magnon-polariton bistability in a cavity magnonics system consisting of cavity photons strongly interacting with the magnons in a small yttrium iron garnet (YIG) sphere. The bistable behaviors emerged as sharp frequency switchings of the cavity magnon polaritons (CMPs) and related to the transition between states with large and small numbers of polaritons. In our experiment, we align, respectively, the [100] and [110] crystallographic axes of the YIG sphere parallel to the static magnetic field and find very different bistable behaviors (e.g., clockwise and counter-clockwise hysteresis loops) in these two cases. The experimental results are well fitted and explained as being due to the Kerr nonlinearity with either a positive or negative coefficient. Moreover, when the magnetic field is tuned away from the anticrossing point of CMPs, we observe simultaneous bistability of both magnons and cavity photons by applying a drive field on the lower branch.

  17. Niobium LEP 2 accelerating cavities

    CERN Multimedia

    An accelerating cavity from LEP. This could be cut open to show the layer of niobium on the inside. Operating at 4.2 degrees above absolute zero, the niobium is superconducting and carries an accelerating field of 6 million volts per metre with negligible losses. Each cavity has a surface of 6 m2. The niobium layer is only 1.2 microns thick, ten times thinner than a hair. Such a large area had never been coated to such a high accuracy. A speck of dust could ruin the performance of the whole cavity so the work had to be done in an extremely clean environment. These challenging requirements pushed European industry to new achievements. 256 of these cavities were used in an upgrade of the LEP accelerator to double the energy of the particle beams.

  18. Loggerhead oral cavity morphometry study

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Standard external morphometrics and internal oral cavity morphometrics data were collected on wild and captive reared loggerhead sea turtles in size classes ranging...

  19. SRF Cavity Fabrication and Materials

    CERN Document Server

    Singer, W

    2014-07-17

    The technological and metallurgical requirements of material for highgradient superconducting cavities are described. High-purity niobium, as the preferred metal for the fabrication of superconducting accelerating cavities, should meet exact specifications. The content of interstitial impurities such as oxygen, nitrogen, and carbon must be below 10μg/g. The hydrogen content should be kept below 2μg/g to prevent degradation of the Q-value under certain cool-down conditions. The material should be free of flaws (foreign material inclusions or cracks and laminations) that can initiate a thermal breakdown. Defects may be detected by quality control methods such as eddy current scanning and identified by a number of special methods. Conventional and alternative cavity fabrication methods are reviewed. Conventionally, niobium cavities are fabricated from sheet niobium by the formation of half-cells by deep drawing, followed by trim machining and Electron-Beam Welding (EBW). The welding of half-cells is a delicate...

  20. Bistability of Cavity Magnon Polaritons.

    Science.gov (United States)

    Wang, Yi-Pu; Zhang, Guo-Qiang; Zhang, Dengke; Li, Tie-Fu; Hu, C-M; You, J Q

    2018-02-02

    We report the first observation of the magnon-polariton bistability in a cavity magnonics system consisting of cavity photons strongly interacting with the magnons in a small yttrium iron garnet (YIG) sphere. The bistable behaviors emerged as sharp frequency switchings of the cavity magnon polaritons (CMPs) and related to the transition between states with large and small numbers of polaritons. In our experiment, we align, respectively, the [100] and [110] crystallographic axes of the YIG sphere parallel to the static magnetic field and find very different bistable behaviors (e.g., clockwise and counter-clockwise hysteresis loops) in these two cases. The experimental results are well fitted and explained as being due to the Kerr nonlinearity with either a positive or negative coefficient. Moreover, when the magnetic field is tuned away from the anticrossing point of CMPs, we observe simultaneous bistability of both magnons and cavity photons by applying a drive field on the lower branch.

  1. Sterility of the uterine cavity

    DEFF Research Database (Denmark)

    Møller, Birger R.; Kristiansen, Frank V.; Thorsen, Poul

    1995-01-01

    In a prospective open study the sterility of the uterine cavity was evaluated in 99 women admitted for hysterectomy. The indications for hysterectomy were in most cases persistent irregular vaginal bleeding and fibromyomas of the uterus. Samples for both aerobic and anaerobic bacteria, Chlamydia ...... which may play a causative role in endometritis. The results indicate that inflammation of the uterine cavity should be evaluated by hysteroscopic examination before hysterectomy is undertaken in patients with persistent irregular vaginal bleeding. Udgivelsesdato: 1995-Mar...

  2. LEP Radio Frequency Copper Cavity

    CERN Multimedia

    The pulse of a particle accelerator. 128 of these radio frequency cavities were positioned around CERN's 27-kilometre LEP ring to accelerate electrons and positrons. The acceleration was produced by microwave electric oscillations at 352 MHz. The electrons and positrons were grouped into bunches, like beads on a string, and the copper sphere at the top stored the microwave energy between the passage of individual bunches. This made for valuable energy savings as it reduced the heat generated in the cavity.

  3. Nurse-administered propofol sedation for endoscopy

    DEFF Research Database (Denmark)

    Jensen, J T; Vilmann, P; Horsted, T

    2011-01-01

    The aim of the present study was to perform a risk analysis during the implementation phase of nurse-administered propofol sedation (NAPS) and to validate our structured training program.......The aim of the present study was to perform a risk analysis during the implementation phase of nurse-administered propofol sedation (NAPS) and to validate our structured training program....

  4. Computer-Administered Interviews and Rating Scales

    Science.gov (United States)

    Garb, Howard N.

    2007-01-01

    To evaluate the value of computer-administered interviews and rating scales, the following topics are reviewed in the present article: (a) strengths and weaknesses of structured and unstructured assessment instruments, (b) advantages and disadvantages of computer administration, and (c) the validity and utility of computer-administered interviews…

  5. 21 CFR 872.3260 - Cavity varnish.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cavity varnish. 872.3260 Section 872.3260 Food and... DENTAL DEVICES Prosthetic Devices § 872.3260 Cavity varnish. (a) Identification. Cavity varnish is a device that consists of a compound intended to coat a prepared cavity of a tooth before insertion of...

  6. Engineering interactions between long-lived cavities

    Science.gov (United States)

    Gao, Yvonne; Rosenblum, Serge; Reinhold, Philip; Wang, Chen; Axline, Christopher; Frunzio, Luigi; Girvin, Steven M.; Jiang, Liang; Mirrahimi, Mazyar; Devoret, Michel H.; Schoelkopf, Robert J.

    The availability of large Hilbert dimensions and outstanding coherence properties make superconducting cavities promising systems for storing quantum information. Recent experiments in cQED has demonstrated that redundantly encoding logical qubits in such cavities is a hardware-efficient approach toward error-correctable quantum memories. In order to tap into the power of these protected memories for quantum information processing, robust inter-cavity operations are required. A simple way to realise such operations between two cavities is using the non-linearity of the Josephson junction. To do so, we adopt a multi-cavity architecture where a fixed-frequency, single junction transmon simultaneously couples to two highly coherent 3D cavities. Using only external RF drives, we demonstrate transmon-cavity as well as cavity-cavity SWAP operations and show that such interactions are essential building blocks for implementing multi-cavity conditional logics.

  7. Thermal conditions within tree cavities in ponderosa pine (Pinus ponderosa) forests: potential implications for cavity users

    Science.gov (United States)

    Vierling, Kerri T.; Lorenz, Teresa J.; Cunningham, Patrick; Potterf, Kelsi

    2017-11-01

    Tree cavities provide critical roosting and breeding sites for multiple species, and thermal environments in these cavities are important to understand. Our objectives were to (1) describe thermal characteristics in cavities between June 3 and August 9, 2014, and (2) investigate the environmental factors that influence cavity temperatures. We placed iButtons in 84 different cavities in ponderosa pine (Pinus ponderosa) forests in central Washington, and took hourly measurements for at least 8 days in each cavity. Temperatures above 40 °C are generally lethal to developing avian embryos, and 18% of the cavities had internal temperatures of ≥ 40 °C for at least 1 h of each day. We modeled daily maximum cavity temperature, the amplitude of daily cavity temperatures, and the difference between the mean internal cavity and mean ambient temperatures as a function of several environmental variables. These variables included canopy cover, tree diameter at cavity height, cavity volume, entrance area, the hardness of the cavity body, the hardness of the cavity sill (which is the wood below the cavity entrance which forms the barrier between the cavity and the external environment), and sill width. Ambient temperature had the largest effect size for maximum cavity temperature and amplitude. Larger trees with harder sills may provide more thermally stable cavity environments, and decayed sills were positively associated with maximum cavity temperatures. Summer temperatures are projected to increase in this region, and additional research is needed to determine how the thermal environments of cavities will influence species occupancy, breeding, and survival.

  8. Cavity QED with atomic mirrors

    Science.gov (United States)

    Chang, D. E.; Jiang, L.; Gorshkov, A. V.; Kimble, H. J.

    2012-06-01

    A promising approach to merge atomic systems with scalable photonics has emerged recently, which consists of trapping cold atoms near tapered nanofibers. Here, we describe a novel technique to achieve strong, coherent coupling between a single atom and photon in such a system. Our approach makes use of collective enhancement effects, which allow a lattice of atoms to form a high-finesse cavity within the fiber. We show that a specially designated ‘impurity’ atom within the cavity can experience strongly enhanced interactions with single photons in the fiber. Under realistic conditions, a ‘strong coupling’ regime can be reached, wherein it becomes feasible to observe vacuum Rabi oscillations between the excited impurity atom and a single cavity quantum. This technique can form the basis for a scalable quantum information network using atom-nanofiber systems.

  9. Clinical Pharmacokinetics of Systemically Administered Antileishmanial Drugs

    NARCIS (Netherlands)

    Kip, Anke E; Schellens, Jan H M; Beijnen, Jos H; Dorlo, Thomas P C

    This review describes the pharmacokinetic properties of the systemically administered antileishmanial drugs pentavalent antimony, paromomycin, pentamidine, miltefosine and amphotericin B (AMB), including their absorption, distribution, metabolism and excretion and potential drug-drug interactions.

  10. A SURVEY OF CORONAL CAVITY DENSITY PROFILES

    International Nuclear Information System (INIS)

    Fuller, J.; Gibson, S. E.

    2009-01-01

    Coronal cavities are common features of the solar corona that appear as darkened regions at the base of coronal helmet streamers in coronagraph images. Their darkened appearance indicates that they are regions of lowered density embedded within the comparatively higher density helmet streamer. Despite interfering projection effects of the surrounding helmet streamer (which we refer to as the cavity rim), Fuller et al. have shown that under certain conditions it is possible to use a Van de Hulst inversion of white-light polarized brightness (pB) data to calculate the electron density of both the cavity and cavity rim plasma. In this article, we apply minor modifications to the methods of Fuller et al. in order to improve the accuracy and versatility of the inversion process, and use the new methods to calculate density profiles for both the cavity and cavity rim in 24 cavity systems. We also examine trends in cavity morphology and how departures from the model geometry affect our density calculations. The density calculations reveal that in all 24 cases the cavity plasma has a flatter density profile than the plasma of the cavity rim, meaning that the cavity has a larger density depletion at low altitudes than it does at high altitudes. We find that the mean cavity density is over four times greater than that of a coronal hole at an altitude of 1.2 R sun and that every cavity in the sample is over twice as dense as a coronal hole at this altitude. Furthermore, we find that different cavity systems near solar maximum span a greater range in density at 1.2 R sun than do cavity systems near solar minimum, with a slight trend toward higher densities for systems nearer to solar maximum. Finally, we found no significant correlation of cavity density properties with cavity height-indeed, cavities show remarkably similar density depletions-except for the two smallest cavities that show significantly greater depletion.

  11. Coeliac cavity ultrasonic diagnosis apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Ando, O.; Suwaki, T.

    1983-07-05

    A coeliac cavity ultrasonic diagnosis apparatus is disclosed which includes an ultrasonic transducer or scanner portion adapted to be inserted into a coeliac cavity to effect a sector scan of an ultrasonic beam to produce an ultrasonic image of internal tissues and in which the ultrasonic oscillator on the one hand and an ultrasonic reflecting mirror and rotary disc on the other hand are relatively rotated so as to effect the sector scan of the ultrasonic beam and the rotary angle of the rotary disc is detected so as to obtain a deflecting angle of the ultrasonic beam and a display on a cathode ray tube of a precise ultrasonic picture image.

  12. Protein dynamics: hydration and cavities

    Directory of Open Access Journals (Sweden)

    Heremans K.

    2005-01-01

    Full Text Available The temperature-pressure behavior of proteins seems to be unique among the biological macromolecules. Thermodynamic as well as kinetic data show the typical elliptical stability diagram. This may be extended by assuming that the unfolded state gives rise to volume and enthalpy-driven liquid-liquid transitions. A molecular interpretation follows from the temperature and the pressure dependence of the hydration and cavities. We suggest that positron annihilation spectroscopy can provide additional quantitative evidence for the contributions of cavities to the dynamics of proteins. Only mature amyloid fibrils that form from unfolded proteins are very resistant to pressure treatment.

  13. Nuclear Medicine Program progress report, quarter ending March 31, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, F.F. Jr.; Ambrose, K.R.; Callahan, A.P.; McPherson, D.W.; Mirzadeh, S.; Hasan, A.; Lambert, C.R.; Rice, D.E.

    1992-07-01

    We describe the design synthesis and initial animal testing of a new iodine-131-labeled triglyceride analogue for the potential evaluation of clinical pancreatic insufficiency. The new agent is 1,2-dipalmitoyl-3-[(15-p-iodophenyl)pentadecanoyl] rac-glycerol(1,2-Pal-3-IPPA). Following oral administration of the iodine-125-labeled agent to rats, 34.5+8.8% of the administered activity was excreted in the urine within one day, demonstrating that radioiodinated IPPA is absorbed in the intestine after release from the triglyceride by pancreatic lipase. The final catabolic product of IPPA is then conjugated and excreted via the urinary bladder. Urine analysis following oral administration of this new agent to patients may thus be a new, simple method for the clinical evaluation of various gastrointestinal diseases. The synthesis and the initial biological evaluation of the 3R-isomer of [{sup 125}I]IQNP are also described.

  14. Nuclear Medicine Program progress report, quarter ending March 31, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, F.F. Jr.; Ambrose, K.R.; Callahan, A.P.; McPherson, D.W.; Mirzadeh, S.; Hasan, A.; Lambert, C.R.; Rice, D.E.

    1992-07-01

    We describe the design synthesis and initial animal testing of a new iodine-131-labeled triglyceride analogue for the potential evaluation of clinical pancreatic insufficiency. The new agent is 1,2-dipalmitoyl-3-((15-p-iodophenyl)pentadecanoyl) rac-glycerol(1,2-Pal-3-IPPA). Following oral administration of the iodine-125-labeled agent to rats, 34.5+8.8% of the administered activity was excreted in the urine within one day, demonstrating that radioiodinated IPPA is absorbed in the intestine after release from the triglyceride by pancreatic lipase. The final catabolic product of IPPA is then conjugated and excreted via the urinary bladder. Urine analysis following oral administration of this new agent to patients may thus be a new, simple method for the clinical evaluation of various gastrointestinal diseases. The synthesis and the initial biological evaluation of the 3R-isomer of ({sup 125}I)IQNP are also described.

  15. Conduction cooling systems for linear accelerator cavities

    Science.gov (United States)

    Kephart, Robert

    2017-05-02

    A conduction cooling system for linear accelerator cavities. The system conducts heat from the cavities to a refrigeration unit using at least one cavity cooler interconnected with a cooling connector. The cavity cooler and cooling connector are both made from solid material having a very high thermal conductivity of approximately 1.times.10.sup.4 W m.sup.-1 K.sup.-1 at temperatures of approximately 4 degrees K. This allows for very simple and effective conduction of waste heat from the linear accelerator cavities to the cavity cooler, along the cooling connector, and thence to the refrigeration unit.

  16. Hybrid Vertical-Cavity Laser

    DEFF Research Database (Denmark)

    2010-01-01

    The present invention provides a light source (2) for light circuits on a silicon platform (3). A vertical laser cavity is formed by a gain region (101) arranged between a top mirror (4) and a bottom grating-mirror (12) in a grating region (11) in a silicon layer (10) on a substrate. A waveguide ...

  17. "Grinding" cavities in polyurethane foam

    Science.gov (United States)

    Brower, J. R.; Davey, R. E.; Dixon, W. F.; Robb, P. H.; Zebus, P. P.

    1980-01-01

    Grinding tool installed on conventional milling machine cuts precise cavities in foam blocks. Method is well suited for prototype or midsize production runs and can be adapted to computer control for mass production. Method saves time and materials compared to bonding or hot wire techniques.

  18. On the collapse of cavities

    Science.gov (United States)

    Bourne, N. K.

    The collapse of a single cavity, or a cloud of bubbles has several physical consequences when in proximity to a structure or resident within a material during deformation. The earliest recognized of these was cavitation erosion of the propellers of steam ships. However, other processes include the rapid collapse of cavities leading to hot spots in explosives from which reaction ensues, or the more recent phenomenon of light generation by oscillating single bubbles or clouds. In the collapse of a cavity, the least considered but the most important mechanism is asymmetric closure. One of the consequences of this is the formation of jets leading to local high pressures and shears that result in the damage or reaction mechanisms observed. The challenge for the future remains in understanding the effects of cloud cavitation since it is likely that only one bubble in perhaps millions in a cloud catalyses an event. The review follows the author's work in the understanding of shock-induced cavity collapse and highlights several results which indicate the importance of this problem in a variety of fields.

  19. A 200 MHz prebunching cavity

    CERN Multimedia

    1977-01-01

    This cavity was installed in the PS ring and proved very efficient in providing a modulation on the PS beam before it is injected into the SPS machine. Moreover it allowed longitudinal instabilities studies at high intensities. Roberto Cappi stands on the left.

  20. Improving cooling of cavity blackbodies

    Science.gov (United States)

    Barrat, Catherine; Chauvel, Gildas

    2013-10-01

    A cavity blackbody is the appropriate IR reference source for IR sensors which require high radiance levels. It combines high emissivity independent from wavelength and high speed warm up and high stability thanks to its light trap structure. However, the inconvenient of this structure is that it leads to a prohibitive cooling time. HGH developed a method to speed up the cooling time.

  1. Seismic resonances of acoustic cavities

    Science.gov (United States)

    Schneider, F. M.; Esterhazy, S.; Perugia, I.; Bokelmann, G.

    2016-12-01

    The goal of an On-Site Inspection (OSI) is to clarify at a possible testsite whether a member state of the Comprehensive nuclear Test Ban Treaty (CTBT)has violated its rules by conducting a underground nuclear test. Compared toatmospheric and underwater tests underground nuclear explosions are the mostdifficult to detect.One primary structural target for the field team during an OSI is the detectionof an underground cavity, created by underground nuclear explosions. Theapplication of seismic-resonances of the cavity for its detection has beenproposed in the CTBT by mentioning "resonance seismometry" as possibletechnique during OSIs. We modeled the interaction of a seismic wave-field withan underground cavity by a sphere filled with an acoustic medium surrounded byan elastic full space. For this setting the solution of the seismic wave-fieldcan be computed analytically. Using this approach the appearance of acousticresonances can be predicted in the theoretical calculations. Resonance peaksappear in the spectrum derived for the elastic domain surrounding the acousticcavity, which scale in width with the density of the acoustic medium. For lowdensities in the acoustic medium as for an gas-filled cavity, the spectralpeaks become very narrow and therefore hard to resolve. The resonancefrequencies, however can be correlated to the discrete set of eigenmodes of theacoustic cavity and can thus be predicted if the dimension of the cavity isknown. Origin of the resonance peaks are internal reverberations of wavescoupling in the acoustic domain and causing an echoing signal that couples outto the elastic domain again. In the gas-filled case the amplitudes in timedomain are very low.Beside theoretical considerations we seek to find real data examples fromsimilar settings. As example we analyze a 3D active seismic data set fromFelsőpetény, Hungary that has been conducted between 2012 and 2014 on behalf ofthe CTBTO. In the subsurface of this area a former clay mine is

  2. Training pharmacy technicians to administer immunizations.

    Science.gov (United States)

    McKeirnan, Kimberly C; Frazier, Kyle R; Nguyen, Maryann; MacLean, Linda Garrelts

    To evaluate the effectiveness of an immunization training program for pharmacy technicians on technicians' self-reported confidence, knowledge, and number of vaccines administered. A one-group pre- and posttest study was conducted with certified pharmacy technicians from Albertsons and Safeway community pharmacies in Idaho. Thirty pharmacy technicians were recruited to participate in an immunization administration training program comprising a 2-hour home study and a 2-hour live training. Pharmacy technician scores on a 10-question knowledge assessment, responses on a pre- and posttraining survey, and number of immunizations administered in the 6-month period following the training were collected. Twenty-five pharmacy technicians completed the home study and live portions of the immunization training program. All 29 pharmacy technicians who took the home study assessment passed with greater than 70% competency on the first attempt. Technicians self-reported increased confidence with immunization skills between the pretraining survey and the posttraining survey. From December 2016 to May 2017, the technicians administered 953 immunizations with 0 adverse events reported. For the first time, pharmacy technicians have legally administered immunizations in the United States. Trained pharmacy technicians demonstrated knowledge of vaccination procedures and self-reported improved confidence in immunization skills and administered immunizations after participating in a 4-hour training program. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  3. Waveguide based external cavity semiconductor lasers

    NARCIS (Netherlands)

    Oldenbeuving, Ruud; Klein, E.J.; Offerhaus, Herman L.; Lee, Christopher James; Verhaegen, M.; Boller, Klaus J.

    2012-01-01

    We report on progress of the project waveguide based external cavity semiconductor laser (WECSL) arrays. Here we present the latest results on our efforts to mode lock an array of tunable, external cavity semiconductor lasers.

  4. Optical cavity furnace for semiconductor wafer processing

    Science.gov (United States)

    Sopori, Bhushan L.

    2014-08-05

    An optical cavity furnace 10 having multiple optical energy sources 12 associated with an optical cavity 18 of the furnace. The multiple optical energy sources 12 may be lamps or other devices suitable for producing an appropriate level of optical energy. The optical cavity furnace 10 may also include one or more reflectors 14 and one or more walls 16 associated with the optical energy sources 12 such that the reflectors 14 and walls 16 define the optical cavity 18. The walls 16 may have any desired configuration or shape to enhance operation of the furnace as an optical cavity 18. The optical energy sources 12 may be positioned at any location with respect to the reflectors 14 and walls defining the optical cavity. The optical cavity furnace 10 may further include a semiconductor wafer transport system 22 for transporting one or more semiconductor wafers 20 through the optical cavity.

  5. An economical wireless cavity-nest viewer

    Science.gov (United States)

    Daniel P. Huebner; Sarah R. Hurteau

    2007-01-01

    Inspection of cavity nests and nest boxes is often required during studies of cavity-nesting birds, and fiberscopes and pole-mounted video cameras are sometimes used for such inspection. However, the cost of these systems may be prohibitive for some potential users. We describe a user-built, wireless cavity viewer that can be used to access cavities as high as 15 m and...

  6. Cavity QED experiments with ion Coulomb crystals

    DEFF Research Database (Denmark)

    Herskind, Peter Fønss; Dantan, Aurélien; Marler, Joan

    2009-01-01

    Cavity QED experimental results demonstrating collective strong coupling between ensembles of atomic ions cooled into Coulomb crystals and optical cavity fields have been achieved. Collective Zeeman coherence times of milliseconds have furthermore been obtained.......Cavity QED experimental results demonstrating collective strong coupling between ensembles of atomic ions cooled into Coulomb crystals and optical cavity fields have been achieved. Collective Zeeman coherence times of milliseconds have furthermore been obtained....

  7. Diagram of a LEP superconducting cavity

    CERN Multimedia

    1991-01-01

    This diagram gives a schematic representation of the superconducting radio-frequency cavities at LEP. Liquid helium is used to cool the cavity to 4.5 degrees above absolute zero so that very high electric fields can be produced, increasing the operating energy of the accelerator. Superconducting cavities were used only in the LEP-2 phase of the accelerator, from 1996 to 2000.

  8. Growth Performance of Cockerels Administered Crude Follicular ...

    African Journals Online (AJOL)

    This Study was conducted to assess the performance of cockerels administered crude follicular and testicular fluids. Two hundred (200) day old Hyaline white cockerel chicks were randomly assigned to five different treatments namely control (T1), 0.5mls follicular fluid (T2), 25% testicular fluid (T3), 0.25ml follicular fluid (T4) ...

  9. Training and experience of doctors administering obstetric ...

    African Journals Online (AJOL)

    Background All the published Saving Mothers Reports generated by the National Committee of the Confidential Enquiries into Maternal Deaths in South Africa have associated anaesthesia-related maternal deaths with the lack of skills of the doctors administering the anaesthesia. The Reports have shown the Free State to ...

  10. Gastrophysics of the Oral Cavity.

    Science.gov (United States)

    Mouritsen, Ole G

    2016-01-01

    Gastrophysics is the science that pertains to the physical and physico-chemical description of the empirical world of gastronomy, with focus on sensory perception in the oral cavity and how it is related to the materials properties of food and cooking processes. Flavor (taste and smell), mouthfeel, chemesthesis, and astringency are all related to the chemical properties and the texture of the food and how the food is transformed in the oral cavity. The present topical review will primarily focus attention on the somatosensory perception of food (mouthfeel or texture) and how it interacts with basic tastes (sour, bitter, sweet, salty, and umami) and chemesthetic action. Issues regarding diet, nutrition, and health will be put into an evolutionary perspective, and some mention will be made of umami and its importance for (oral) health.

  11. A micropillar for cavity optomechanics

    Science.gov (United States)

    Kuhn, Aurélien; Neuhaus, Leonhard; Van Brackel, Emmanuel; Chartier, Claude; Ducloux, Olivier; Le Traon, Olivier; Michel, Christophe; Pinard, Laurent; Flaminio, Raffaele; Deléglise, Samuel; Briant, Tristan; Cohadon, Pierre-François; Heidmann, Antoine

    2014-12-01

    Demonstrating the quantum ground state of a macroscopic mechanical object is a major experimental challenge in physics, at the origin of the rapid emergence of cavity optomechanics. We have developed a new generation of optomechanical devices, based on a microgram quartz micropillar with a very high mechanical quality factor. The structure is used as end mirror in a Fabry-Perot cavity with a high optical finesse, leading to ultra-sensitive interferometric measurement of the resonator displacement. We expect to reach the ground state of this optomechanical resonator by combining cryogenic cooling in a dilution fridge at 30 mK and radiation-pressure cooling. We have already carried out a quantum-limited measurement of the micropillar thermal noise at low temperature.

  12. Droplet based cavities and lasers

    DEFF Research Database (Denmark)

    Mølhave, Kristian; Kristensen, Anders; Mortensen, Asger

    2009-01-01

    The self-organized and molecularly smooth surface on liquid microdroplets makes them attractive as optical cavities with very high quality factors. This chapter describes the basic theory of optical modes in spherical droplets. The mechanical properties including vibrational excitation are also...... described, and their implications for microdroplet resonator technology are discussed. Optofluidic implementations of microdroplet resonators are reviewed with emphasis on the basic optomechanical properties....

  13. Optomechanic interactions in phoxonic cavities

    Directory of Open Access Journals (Sweden)

    Bahram Djafari-Rouhani

    2014-12-01

    Full Text Available Phoxonic crystals are periodic structures exhibiting simultaneous phononic and photonic band gaps, thus allowing the confinement of both excitations in the same cavity. The phonon-photon interaction can be enhanced due to the overlap of both waves in the cavity. In this paper, we discuss some of our recent theoretical works on the strength of the optomechanic coupling, based on both photoelastic and moving interfaces mechanisms, in different (2D, slabs, strips phoxonic crystals cavities. The cases of two-dimensional infinite and slab structures will enable us to mention the important role of the symmetry and degeneracy of the modes, as well as the role of the materials whose photoelastic constants can be wavelength dependent. Depending on the phonon-photon pair, the photoelastic and moving interface mechanisms can contribute in phase or out-of-phase. Then, the main part of the paper will be devoted to the optomechanic interaction in a corrugated nanobeam waveguide exhibiting dual phononic/photonic band gaps. Such structures can provide photonic modes with very high quality factor, high frequency phononic modes of a few GHz inside a gap and optomechanical coupling rate reaching a few MHz.

  14. Optomechanic interactions in phoxonic cavities

    Energy Technology Data Exchange (ETDEWEB)

    Djafari-Rouhani, Bahram; Oudich, Mourad; Pennec, Yan [Institut d’Electronique, de Microélectronique et de Nanotechnologie (IEMN), UMR CNRS 8520, UFR de physique, Université Lille1, Cité Scientifique, 59652, Villeneuve d’Ascq (France); El-Jallal, Said [Institut d’Electronique, de Microélectronique et de Nanotechnologie (IEMN), UMR CNRS 8520, UFR de physique, Université Lille1, Cité Scientifique, 59652, Villeneuve d’Ascq (France); Physique du Rayonnement et de l’Interaction Laser Matière, Faculté des sciences, Université de Moulay Ismail, Meknès (Morocco)

    2014-12-15

    Phoxonic crystals are periodic structures exhibiting simultaneous phononic and photonic band gaps, thus allowing the confinement of both excitations in the same cavity. The phonon-photon interaction can be enhanced due to the overlap of both waves in the cavity. In this paper, we discuss some of our recent theoretical works on the strength of the optomechanic coupling, based on both photoelastic and moving interfaces mechanisms, in different (2D, slabs, strips) phoxonic crystals cavities. The cases of two-dimensional infinite and slab structures will enable us to mention the important role of the symmetry and degeneracy of the modes, as well as the role of the materials whose photoelastic constants can be wavelength dependent. Depending on the phonon-photon pair, the photoelastic and moving interface mechanisms can contribute in phase or out-of-phase. Then, the main part of the paper will be devoted to the optomechanic interaction in a corrugated nanobeam waveguide exhibiting dual phononic/photonic band gaps. Such structures can provide photonic modes with very high quality factor, high frequency phononic modes of a few GHz inside a gap and optomechanical coupling rate reaching a few MHz.

  15. Status of the ILC Crab Cavity Development

    Energy Technology Data Exchange (ETDEWEB)

    Burt, G.; Dexter, A.; /Cockcroft Inst. Accel. Sci. Tech.; Beard, C.; Goudket, P.; McIntosh, P.; /Daresbury; Bellantoni, L.; /Fermilab; Grimm, T.; Li, Z.; Xiao, L.; /SLAC

    2011-10-20

    The International Linear Collider (ILC) will require two dipole cavities to 'crab' the electron and positron bunches prior to their collision. It is proposed to use two 9 cell SCRF dipole cavities operating at a frequency of 3.9 GHz, with a transverse gradient of 3.8MV/m in order to provide the required transverse kick. Extensive numerical modelling of this cavity and its couplers has been performed. Aluminium prototypes have been manufactured and tested to measure the RF properties of the cavity and couplers. In addition single cell niobium prototypes have been manufactured and tested in a vertical cryostat. The International Collider (ILC) [1] collides bunches of electrons and positrons at a crossing angle of 14 mrad. The angle between these bunches causes a loss in luminosity due to geometric effects [2]. The luminosity lost from this geometric effect can be recovered by rotating the bunches into alignment prior to collision. One possible method of rotating the bunches is to use a crab cavity [3]. A crab cavity is a transverse defecting cavity, where the phase of the cavity is such that the head and tail of the bunch receive equal and opposite kicks. As the bunches are only 500 nm wide in the horizontal plane, the cavity phase must be strictly controlled to avoid the bunch centre being deflected too much. In order to keep the phase stability within the required limits it is required that the cavity be superconducting to avoid thermal effects in both the cavity and its RF source. At the location of the crab cavity in the ILC there is only 23 cm separation between the centre of the cavity and the extraction line, hence the cavity must be small enough to fit in this space. This, along with the difficulty of making high frequency SRF components, set the frequency of the cavity to 3.9 GHz.

  16. Investigation of superconducting niobium 1170 MHz cavities

    International Nuclear Information System (INIS)

    Anashin, V.V.; Bibko, S.I.; Fadeyev, E.I.

    1988-01-01

    The design, fabrication and experiments with superconducting L-band single cell cavities are described. These cavities model a cell of an accelerating RF structure. The cavities have been fabricated from technical grade and higher purity grade sheet niobium using deep-drawing, electron beam welding and chemical polishing. They have spherical geometry and are excited in the TM 010 mode. A computerized set-up was used for cavity tests. Qo=1.5 x 10 9 and E acc = 4.3 MV/m were obtained in the cavity made of higher purity grade niobium. 6 references, 8 figures, 3 tables

  17. Cavity Optomechanics at Millikelvin Temperatures

    Science.gov (United States)

    Meenehan, Sean Michael

    The field of cavity optomechanics, which concerns the coupling of a mechanical object's motion to the electromagnetic field of a high finesse cavity, allows for exquisitely sensitive measurements of mechanical motion, from large-scale gravitational wave detection to microscale accelerometers. Moreover, it provides a potential means to control and engineer the state of a macroscopic mechanical object at the quantum level, provided one can realize sufficiently strong interaction strengths relative to the ambient thermal noise. Recent experiments utilizing the optomechanical interaction to cool mechanical resonators to their motional quantum ground state allow for a variety of quantum engineering applications, including preparation of non-classical mechanical states and coherent optical to microwave conversion. Optomechanical crystals (OMCs), in which bandgaps for both optical and mechanical waves can be introduced through patterning of a material, provide one particularly attractive means for realizing strong interactions between high-frequency mechanical resonators and near-infrared light. Beyond the usual paradigm of cavity optomechanics involving isolated single mechanical elements, OMCs can also be fashioned into planar circuits for photons and phonons, and arrays of optomechanical elements can be interconnected via optical and acoustic waveguides. Such coupled OMC arrays have been proposed as a way to realize quantum optomechanical memories, nanomechanical circuits for continuous variable quantum information processing and phononic quantum networks, and as a platform for engineering and studying quantum many-body physics of optomechanical meta-materials. However, while ground state occupancies (that is, average phonon occupancies less than one) have been achieved in OMC cavities utilizing laser cooling techniques, parasitic absorption and the concomitant degradation of the mechanical quality factor fundamentally limit this approach. On the other hand, the high

  18. STRUCTURAL ANALYSIS OF SUPERCONDUCTING ACCELERATOR CAVITIES

    International Nuclear Information System (INIS)

    Schrage, D.

    2000-01-01

    The static and dynamic structural behavior of superconducting cavities for various projects was determined by finite element structural analysis. The β = 0.61 cavity shape for the Neutron Science Project was studied in detail and found to meet all design requirements if fabricated from five millimeter thick material with a single annular stiffener. This 600 MHz cavity will have a Lorentz coefficient of minus1.8 Hz/(Mv/meter) 2 and a lowest structural resonance of more than 100 Hz. Cavities at β = 0.48, 0.61, and 0.77 were analyzed for a Neutron Science Project concept which would incorporate 7-cell cavities. The medium and high beta cavities were found to meet all criteria but it was not possible to generate a β = 0.48 cavity with a Lorentz coefficient of less than minus3 Hz/(Mv/meter) 2

  19. Novel Geometries for the LHC Crab Cavity

    Energy Technology Data Exchange (ETDEWEB)

    B. Hall, G. Burt, C. Lingwood, R. Rimmer, H. Wang

    2010-05-23

    The planned luminosity upgrade to LHC is likely to necessitate a large crossing angle and a local crab crossing scheme. For this scheme crab cavities align bunches prior to collision. The scheme requires at least four such cavities, a pair on each beam line either side of the interaction point (IP). Upstream cavities initiate rotation and downstream cavities cancel rotation. Cancellation is usually done at a location where the optics has re-aligned the bunch. The beam line separation near the IP necessitates a more compact design than is possible with elliptical cavities such as those used at KEK. The reduction in size must be achieved without an increase in the operational frequency to maintain compatibility with the long bunch length of the LHC. This paper proposes a suitable superconducting variant of a four rod coaxial deflecting cavity (to be phased as a crab cavity), and presents analytical models and simulations of suitable designs.

  20. Novel Geometries for the LHC Crab Cavity

    Energy Technology Data Exchange (ETDEWEB)

    B. Hall,G. Burt,C. Lingwood,Robert Rimmer,Haipeng Wang; Hall, B. [CI Lancaster University (Great Britain); Burt, G. [CI Lancaster University (Great Britain); Lingwood, C. [CI Lancaster University (Great Britain); Rimmer, Robert [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Wang, Haipeng [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2010-05-01

    The planned luminosity upgrade to LHC is likely to necessitate a large crossing angle and a local crab crossing scheme. For this scheme crab cavities align bunches prior to collision. The scheme requires at least four such cavities, a pair on each beam line either side of the interaction point (IP). Upstream cavities initiate rotation and downstream cavities cancel rotation. Cancellation is usually done at a location where the optics has re-aligned the bunch. The beam line separation near the IP necessitates a more compact design than is possible with elliptical cavities such as those used at KEK. The reduction in size must be achieved without an increase in the operational frequency to maintain compatibility with the long bunch length of the LHC. This paper proposes a suitable superconducting variant of a four rod coaxial deflecting cavity (to be phased as a crab cavity), and presents analytical models and simulations of suitable designs.

  1. Nurse-administered propofol sedation for endoscopy

    DEFF Research Database (Denmark)

    Jensen, J T; Vilmann, P; Horsted, T

    2011-01-01

    BACKGROUND AND STUDY AIMS: The aim of the present study was to perform a risk analysis during the implementation phase of nurse-administered propofol sedation (NAPS) and to validate our structured training program. PATIENTS AND METHODS: A structured training program was developed both for endosco......BACKGROUND AND STUDY AIMS: The aim of the present study was to perform a risk analysis during the implementation phase of nurse-administered propofol sedation (NAPS) and to validate our structured training program. PATIENTS AND METHODS: A structured training program was developed both...... for endoscopists and for endoscopy nurses who were administering propofol sedation. The nurses' program comprised a 6-week course including theoretical and practical training in airway management, and the endoscopists' program consisted of 2.5 h of theory and a short course in practical airway management....... In the implementation phase, data from 1822 endoscopic procedures in 1764 patients were prospectively collected. All adverse events related to sedation were recorded (defined as oxygen saturation change in blood pressure > 20 mmHg). RESULTS: 78 cases...

  2. Understanding cavity QED effects from cavity classical electrodynamics

    International Nuclear Information System (INIS)

    Taddei, M.M.; Kort-Kamp, W.J.M.; Farina, C.

    2011-01-01

    Full text: Our work intends to show how cavity classical electrodynamics can be used for achieving results with direct quantum analogues. It is shown how the classical interaction between a real radiating electric dipole and a perfectly-conducting surface can be used to obtain information about some cavity quantum electrodynamics effects related to radiative properties of atomic systems. Based on the case of an oscillating electric dipole (a classical representation of an excited atom) in front of a perfectly-conducting sphere, two main physical quantities can be computed, the classical dipole frequency shift and the change in the rate of energy loss from radiation reaction, both due to the presence of the sphere. The link from classical to quantum can be made via interpreting, for example, the dipole frequency as the atom's dominant transition frequency. The frequency shift due to the sphere can be related through E = (h/2π) to the energy shift of the system, i.e., the dispersive interaction between the atom and the sphere; while the change in energy loss can be related to the alteration of the atom's spontaneous emission due to the sphere. The amazing result is that this classical method, once corresponded classical quantities to quantum ones such as exemplified above with frequency, can predict the two above-mentioned quantum effects analytically with the correct functional dependencies on all geometric and atomic parameters, being off only by a constant pre factor. (author)

  3. Temperature Structure of a Coronal Cavity

    Science.gov (United States)

    Kucera, T. A.; Gibson, S. E.; Schmit, D. J.

    2011-01-01

    we analyze the temperature structure of a coronal cavity observed in Aug. 2007. coronal cavities are long, low-density structures located over filament neutral lines and are often seen as dark elliptical features at the solar limb in white light, EUV and x-rays. when these structures erupt they form the cavity portions of CMEs. It is important to establish the temperature structure of cavities in order to understand the thermodynamics of cavities in relation to their three-dimensional magnetic structure. To analyze the temperature we compare temperature ratios of a series of iron lines observed by the Hinode/EUv Imaging spectrometer (EIS). We also use those lines to constrain a forward model of the emission from the cavity and streamer. The model assumes a coronal streamer with a tunnel-like cavity with elliptical cross-section and a Gaussian variation of height along the tunnel lenth. Temperature and density can be varied as a function of altitude both in the cavity and streamer. The general cavity morphology and the cavity and streamer density have already been modeled using data from STEREO's SECCHI/EUVI and Hinode/EIS (Gibson et al 2010 and Schmit & Gibson 2011).

  4. Cancer of the oral cavity.

    Science.gov (United States)

    Montero, Pablo H; Patel, Snehal G

    2015-07-01

    Cancer of the oral cavity is one of the most common malignancies worldwide. Although early diagnosis is relatively easy, presentation with advanced disease is not uncommon. The standard of care is primary surgical resection with or without postoperative adjuvant therapy. Improvements in surgical techniques combined with the routine use of postoperative radiation or chemoradiation therapy have resulted in improved survival. Successful treatment is predicated on multidisciplinary treatment strategies to maximize oncologic control and minimize impact of therapy on form and function. Prevention of oral cancer requires better education about lifestyle-related risk factors, and improved awareness and tools for early diagnosis. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Administering stuttering modification therapy in school settings.

    Science.gov (United States)

    Williams, Dale F; Dugan, Peter M

    2002-08-01

    Stuttering modification techniques can be used effectively in the school setting. In fact, speech-language pathologists can use this environment to their advantage to address not only disfluency but also the emotional and behavioral aspects of stuttering. Toward this end, stuttering modification goals and techniques are outlined, with a discussion of how to adapt them to school environments. Specific topics include writing clear, measurable IEP goals, taking advantage of the school setting to implement these goals, administering stuttering modification within a group therapy mode, involving parents and teachers, and monitoring progress.

  6. Rebuild of Capture Cavity 1 at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Harms, E. [Fermilab; Arkan, T. [Fermilab; Borissov, E. [Fermilab; Dhanaraj, N. [Fermilab; Hocker, A. [Fermilab; Orlov, Y. [Fermilab; Peterson, T. [Fermilab; Premo, K. [Fermilab

    2014-01-01

    The front end of the proposed Advanced Superconducting Test Accelerator at Fermilab employs two single cavity cryomodules, known as 'Capture Cavity 1' and 'Capture Cavity 2', for the first stage of acceleration. Capture Cavity 1 was previously used as the accelerating structure for the A0 Photoinjector to a peak energy of ~14 MeV. In its new location a gradient of ~25 MV/m is required. This has necessitated a major rebuild of the cryomodule including replacement of the cavity with a higher gradient one. Retrofitting the cavity and making upgrades to the module required significant redesign. The design choices and their rationale, summary of the rebuild, and early test results are presented.

  7. Cantilever piezoelectric energy harvester with multiple cavities

    International Nuclear Information System (INIS)

    S Srinivasulu Raju; M Umapathy; G Uma

    2015-01-01

    Energy harvesting employing piezoelectric materials in mechanical structures such as cantilever beams, plates, diaphragms, etc, has been an emerging area of research in recent years. The research in this area is also focused on structural tailoring to improve the harvested power from the energy harvesters. Towards this aim, this paper presents a method for improving the harvested power from a cantilever piezoelectric energy harvester by introducing multiple rectangular cavities. A generalized model for a piezoelectric energy harvester with multiple rectangular cavities at a single section and two sections is developed. A method is suggested to optimize the thickness of the cavities and the number of cavities required to generate a higher output voltage for a given cantilever beam structure. The performance of the optimized energy harvesters is evaluated analytically and through experimentation. The simulation and experimental results show that the performance of the energy harvester can be increased with multiple cavities compared to the harvester with a single cavity. (paper)

  8. Unique space saving accelerator cavity design

    International Nuclear Information System (INIS)

    Kim, H.; Fugitt, J.; Crosby, F.; Johnson, R.

    1981-03-01

    A cavity with 3 series gaps was designed and modeled to operate at 70 MHz as a SuperHILAC post acceleration buncher (8.5 MeV/A). Because of a cross-coupling scheme, the 3 cells operate in the 1/2 β lambda mode instead of the β lambda mode of an Alvarez cavity. This coupling results in a cavity with diameter reduced from 3 to less than one meter and a length half that of an Alvarez cavity for the same energy gain. The 3 gaps are electrically in parallel but mechanically in series. The cavity has high Q and shunt impedance. This type of cavity appears to be useful for low velocity beams with β less than or equal to 0.2

  9. Design of 325 MHz spoke cavity

    International Nuclear Information System (INIS)

    Sha Peng; Huang Hong; Dai Jianping; Zu Guoquan; Li Han

    2012-01-01

    Spoke cavity can be used in the low-energy section of the proton accelerator. It has many significant advantages: compact structure, high value of R/Q, etc. The ADS (Accelerator Driven System) project will adopt many spoke cavities with different β values. Therefore, IHEP has began the research of β=0.14, 325 MHz spoke cavity. In this pa per, the dimensions, RF performances and mechanical properties of it are studied. (authors)

  10. Induced Cavities for Photonic Quantum Gates

    Science.gov (United States)

    Lahad, Ohr; Firstenberg, Ofer

    2017-09-01

    Effective cavities can be optically induced in atomic media and employed to strengthen optical nonlinearities. Here we study the integration of induced cavities with a photonic quantum gate based on Rydberg blockade. Accounting for loss in the atomic medium, we calculate the corresponding finesse and gate infidelity. Our analysis shows that the conventional limits imposed by the blockade optical depth are mitigated by the induced cavity in long media, thus establishing the total optical depth of the medium as a complementary resource.

  11. Ocular toxicity from systemically administered xenobiotics

    Science.gov (United States)

    Gokulgandhi, Mitan R; Vadlapudi, Aswani Dutt; Mitra, Ashim K

    2015-01-01

    Introduction The eye is considered as the most privileged organ because of the blood–ocular barrier that acts as a barrier to systemically administered xenobiotics. However, there has been a significant increase in the number of reports on systemic drug-induced ocular complications. If such complications are left untreated, then it may cause permanent damage to vision. Hence, knowledge of most recent updates on ever-increasing reports of such toxicities has become imperative to develop better therapy while minimizing toxicities. Areas covered The article is mainly divided into anterior and posterior segment manifestations caused by systemically administered drugs. The anterior segment is further elaborated on corneal complications where as the posterior segment is focused on optic nerve, retinal and vitreous complications. Furthermore, this article includes recent updates on acute and chronic ocular predicaments, in addition to discussing various associated symptoms caused by drugs. Expert opinion Direct correlation of ocular toxicities due to systemic drug therapy is evident from current literature. Therefore, it is necessary to have detailed documentation of these complications to improve understanding and predict toxicities. We made an attempt to ensure that the reader is aware of the characteristic ocular complications, the potential for irreversible drug toxicity and indications for cessation. PMID:22803583

  12. [Improving nursing staff accuracy in administering chemotherapy].

    Science.gov (United States)

    Lin, Chin-Ying; Chu, Yun-Li; Chiou, Yen-Gan; Chiang, Ming-Chu

    2009-12-01

    As most anticancer drugs are cytotoxic, their safe and error-free application is important. We analyzed data from the hematology-oncology ward chemotherapy checklist dated January 13th through February 3rd, 2007 and found accuracy rates for chemotherapy drug usage as low as 68.4%. Possible causes identified for this poor result include incomplete chemotherapy standards protocols, lack of chemotherapy quality control, and insufficient chemotherapy knowledge amongst nursing staff. This project aimed to improve the accuracy of nursing staff in administering chemotherapy and to raise nursing staff knowledge regarding chemotherapy. Our strategies for improvement included completing a chemotherapy standards protocol, establishing a chemotherapy quality-control monitoring system, augmenting chemotherapy training and adding appropriate equipment and staff reminders. After strategies were implemented, accuracy in chemotherapy administration rose to 96.7%. Related knowledge amongst nursing staff also improved from an initial 77.5% to 89.2%. Implementing the recommended measures achieved a significant improvement in the accuracy and quality of chemotherapy administered by nursing personnel.

  13. Novel Geometries for the LHC CRAB Cavity

    CERN Document Server

    Hall, Ben

    2010-01-01

    In 2017 the LHC is envisioned to increase its luminosity via an upgrade. This upgrade is likely to require a large crossing angle hence a crab cavity is required to align the bunches prior to collision. There are two possible schemes for crab cavity implementation, global and local. In a global crab cavity the crab cavity is far from the IP and the bunch rotates back and forward as it traverses around the accelerator in a closed orbit. For this scheme a two-cell elliptical squashed cavity at 800 MHz is preferred. To avoid any potential beam instabilities all the parasitic modes of the cavities must be damped strongly, however crab cavities have lower order and same order modes in addition to the usual higher order modes and hence a novel damping scheme must be used to provide sufficient damping of these modes. In the local scheme two crab cavities are placed at each side of the IP two start and stop rotation of the bunches. This would require crab cavities much smaller transversely than in the global scheme b...

  14. Mechanical Properties of Ingot Nb Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Ciovati, Gianluigi; Dhakal, Pashupati; Kneisel, Peter; Mammosser, John; Matalevich, Joseph; Rao Myneni, Ganapati

    2014-07-01

    This contribution presents the results of measurements of the resonant frequency and of strain along the contour of a single-cell cavity made of ingot Nb subjected to increasing uniform differential pressure, up to 6 atm. The data were used to infer mechanical properties of this material after cavity fabrication, by comparison with the results from simulation calculations done with ANSYS. The objective is to provide useful information about the mechanical properties of ingot Nb cavities which can be used in the design phase of SRF cavities intended to be built with this material.

  15. Superconducting niobium cavity with cooling fins

    International Nuclear Information System (INIS)

    Isagawa, Shigeru.

    1978-04-01

    Cooling efficiency of a superconducting cavity is shown to be improved by applying a fin structure. Internal heating can be suppressed in a certain degree and the higher rf field is expected to be reached on surfaces of the cavity which is immersed in superfluid He 4 liquid. The rf measurements were made on a C-band niobium cavity with cylindrical and circular fins around the wall. Fields of 39 mT and 25 MV/m were attained for TM 010 mode cavity after surface treatments including high temperature annealing in a UHV furnace. (auth.)

  16. Design of the ILC Crab Cavity System

    Energy Technology Data Exchange (ETDEWEB)

    Adolphsen, C.; Beard, C.; Bellantoni, L.; Burt, G.; Carter, R.; Chase, B.; Church, M.; Dexter, A.; Dykes, M.; Edwards, H.; Goudket, P; Jenkins, R.; Jones, R.M.; Kalinin,; Khabiboulline, T.; Ko, K.; Latina, A.; Li, Z.; Ma, L.; McIntosh, P.; Ng, C.; /SLAC /Daresbury /Fermilab /Cockcroft Inst. Accel. Sci. Tech. /CERN

    2007-08-15

    The International Linear Collider (ILC) has a 14 mrad crossing angle in order to aid extraction of spent bunches. As a result of the bunch shape at the interaction point, this crossing angle at the collision causes a large luminosity loss which can be recovered by rotating the bunches prior to collision using a crab cavity. The ILC baseline crab cavity is a 9-cell superconducting dipole cavity operating at a frequency of 3.9 GHz. In this paper the design of the ILC crab cavity and its phase control system, as selected for the RDR in February 2007 is described in fuller detail.

  17. Primary leiomyosarcoma of peritoneal cavity

    Directory of Open Access Journals (Sweden)

    Jyotsna Naresh Bharti

    2014-03-01

    Full Text Available Leiomyosarcomas of soft tissue are the rare tumors and the retroperitoneum is the most common site involved. We report a case of primary leiomyosarcoma of the peritoneal cavity which clinically presented with suprapubic, freely mobile, nontender mass which measured 10×10 cm in size. Contrast enhanced computed tomography revealed well defined heterogenous hypodense solid cystic mass. The mass was surgically excised out in its entirety. The histopathological examination revealed spindle cells arranged in alternating fascicles having pleomorphic nuclei, indistinct margin and eosinophilic cytoplasm with foci of haemorrhage, necrosis and 5-6 mitosis/HPF. The spindle cells were immunoreactive for smooth muscle actin, desmin and negative for S-100, CD-34 and c-kit. Histopathology and immunohistochemistry were helpful in making the final confirmatory diagnosis. Leiomyosarcomas are aggressive tumors, with poor prognosis and often difficult to treat. The survival rates are lowest among all soft tissue sarcomas.

  18. Epithelial Dysplasia in Oral Cavity

    Directory of Open Access Journals (Sweden)

    Samaneh Shirani

    2014-09-01

    Full Text Available Among oral lesions, we encounter a series of malignant epithelial lesions that go through clinical and histopathologic processes in order to be diagnosed. Identifying these processes along with the etiology knowledge of these lesions is very important in prevention and early treatments. Dysplasia is the step preceding the formation of squamous cell carcinoma in lesions which have the potential to undergo dysplasia. Identification of etiological factors, clinical and histopathologic methods has been the topic of many articles. This article, reviews various articles presenting oral cavity dysplasia, new clinical methods of identifying lesions, and the immunohistochemical research which proposes various markers for providing more precise identification of such lesions. This article also briefly analyzes new treatment methods such as tissue engineering.

  19. Hydrodynamic Drag on Streamlined Projectiles and Cavities

    KAUST Repository

    Jetly, Aditya

    2016-04-19

    The air cavity formation resulting from the water-entry of solid objects has been the subject of extensive research due to its application in various fields such as biology, marine vehicles, sports and oil and gas industries. Recently we demonstrated that at certain conditions following the closing of the air cavity formed by the initial impact of a superhydrophobic sphere on a free water surface a stable streamlined shape air cavity can remain attached to the sphere. The formation of superhydrophobic sphere and attached air cavity reaches a steady state during the free fall. In this thesis we further explore this novel phenomenon to quantify the drag on streamlined shape cavities. The drag on the sphere-cavity formation is then compared with the drag on solid projectile which were designed to have self-similar shape to that of the cavity. The solid projectiles of adjustable weight were produced using 3D printing technique. In a set of experiments on the free fall of projectile we determined the variation of projectiles drag coefficient as a function of the projectiles length to diameter ratio and the projectiles specific weight, covering a range of intermediate Reynolds number, Re ~ 104 – 105 which are characteristic for our streamlined cavity experiments. Parallel free fall experiment with sphere attached streamlined air cavity and projectile of the same shape and effective weight clearly demonstrated the drag reduction effect due to the stress-free boundary condition at cavity liquid interface. The streamlined cavity experiments can be used as the upper bound estimate of the drag reduction by air layers naturally sustained on superhydrophobic surfaces in contact with water. In the final part of the thesis we design an experiment to test the drag reduction capacity of robust superhydrophobic coatings deposited on the surface of various model vessels.

  20. System and method for administering radiation

    International Nuclear Information System (INIS)

    Vogel, T.M.

    1975-01-01

    A system and method for metering the quantity of radiation administered a subject by a source of radiation movable along a path relative to the subject is described. The system cumulatively counts the amount of radiation directed toward the subject during each of a succession of increments of motion of the source. When a predetermined amount of radiation is delivered during an increment, the source is disabled until the source passes into the next increment of displacement. The count of radiation is restarted at the instant the source is disabled, to accumulate accurately any added spurious radiation dosage which may occur and to include that dosage in the count of the permitted amount for the next succeeding increment of motion. Several interlocks for disabling the system in response to various malfunctions are included. Means for controlling the speed of movement of the source and/or the dose rate of the source are also included. (auth)

  1. Tumour targeting with systemically administered bacteria.

    LENUS (Irish Health Repository)

    Morrissey, David

    2012-01-31

    Challenges for oncology practitioners and researchers include specific treatment and detection of tumours. The ideal anti-cancer therapy would selectively eradicate tumour cells, whilst minimising side effects to normal tissue. Bacteria have emerged as biological gene vectors with natural tumour specificity, capable of homing to tumours and replicating locally to high levels when systemically administered. This property enables targeting of both the primary tumour and secondary metastases. In the case of invasive pathogenic species, this targeting strategy can be used to deliver genes intracellularly for tumour cell expression, while non-invasive species transformed with plasmids suitable for bacterial expression of heterologous genes can secrete therapeutic proteins locally within the tumour environment (cell therapy approach). Many bacterial genera have been demonstrated to localise to and replicate to high levels within tumour tissue when intravenously (IV) administered in rodent models and reporter gene tagging of bacteria has permitted real-time visualisation of this phenomenon. Live imaging of tumour colonising bacteria also presents diagnostic potential for this approach. The nature of tumour selective bacterial colonisation appears to be tumour origin- and bacterial species- independent. While originally a correlation was drawn between anaerobic bacterial colonisation and the hypoxic nature of solid tumours, it is recently becoming apparent that other elements of the unique microenvironment within solid tumours, including aberrant neovasculature and local immune suppression, may be responsible. Here, we consider the pre-clinical data supporting the use of bacteria as a tumour-targeting tool, recent advances in the area, and future work required to develop it into a beneficial clinical tool.

  2. Temperature stabilization of optofluidic photonic crystal cavities

    DEFF Research Database (Denmark)

    Kamutsch, Christian; Smith, Cameron L.C.; Graham, Alexandra

    2009-01-01

    demonstrate a PhC cavity with a quality factor of Q15 000 that exhibits a temperature-independent resonance. Temperature-stable cavities constitute a major building block in the development of a large suite of applications from high-sensitivity sensor systems for chemical and biomedical applications...

  3. Tooth structure and fracture strength of cavities

    DEFF Research Database (Denmark)

    Mondelli, José; Sene, Fábio; Ramos, Renata Pereira

    2007-01-01

    This study evaluated, in vitro, the loss of tooth substance after cavity preparation for direct and indirect restorations and its relationship with fracture strength of the prepared teeth. Sixty sound human maxillary first premolars were assigned to 6 groups (n=10). MOD direct composite cavities...

  4. Superconducting rf cavities for accelerator application

    International Nuclear Information System (INIS)

    Proch, D.

    1988-01-01

    The subject of this paper is a review of superconducting cavities for accelerator application (β = 1). The layout of a typical accelerating unit is described and important parameters are discussed. Recent cavity measurements and storage ring beam tests are reported and the present state of the art is summarized

  5. Telescopic Examination of the mastoid Cavity

    OpenAIRE

    Bhandari, Anita; Sharma, Man Prakash; Bapna, A. S.

    1998-01-01

    Otoendoscopy enables viewing of different angles of the tympanomastoid area and approach to them for better prognosis. A comparative study of post-operative mastoid cavities has been done using the Hopkin’s rod telescope, Otoscope and microscope. Various procedures have also been done successfully on the mastoid cavity using the telescope on an outdoor basis.

  6. Toroidal 12 cavity klystron : a novel approach

    International Nuclear Information System (INIS)

    Hazarika, A.B.R.

    2013-01-01

    A toroidal 12 cavity klystron is designed to provide with high energy power with the high frequency microwave RF- plasma generated from it. The cavities are positioned in clock hour positions. The theoretical modeling and designing is done to study the novel approach. (author)

  7. Prototype storage cavity for LEP accelerating RF

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    The principle of an RF storage cavity was demonstrated with this prototype, working at 500 MHz. The final storage cavities were larger, to suit the LEP accelerating frequency of 352.2 MHz. Cu-tubes for watercooling are brazed onto the upper half, the lower half is to follow. See also 8006061, 8109346, 8407619X, and Annual Report 1980, p.115.

  8. The gastro-oesophageal common cavity revisited

    NARCIS (Netherlands)

    Aanen, M. C.; Bredenoord, A. J.; Samsom, M.; Smout, A. J. P. M.

    2006-01-01

    The manometric common cavity phenomenon has been used as indicator of gastro-oesophageal reflux of liquid or gaseous substances. Using combined pH and impedance recording as reference standard the value of a common cavity as indicator of gastro-oesophageal reflux was tested. Ten healthy male

  9. Geometric Model of a Coronal Cavity

    Science.gov (United States)

    Kucera, Therese A.; Gibson, S. E.; Ratawicki, D.; Dove, J.; deToma, G.; Hao, J.; Hudson, H. S.; Marque, C.; McIntosh, P. S.; Reeves, K. K.; hide

    2010-01-01

    We observed a coronal cavity from August 8-18 2007 during a multi-instrument observing campaign organized under the auspices of the International Heliophysical Year (IHY). Here we present initial efforts to model the cavity with a geometrical streamer-cavity model. The model is based the white-light streamer mode] of Gibson et a]. (2003 ), which has been enhanced by the addition of a cavity and the capability to model EUV and X-ray emission. The cavity is modeled with an elliptical cross-section and Gaussian fall-off in length and width inside the streamer. Density and temperature can be varied in the streamer and cavity and constrained via comparison with data. Although this model is purely morphological, it allows for three-dimensional, multi-temperature analysis and characterization of the data, which can then provide constraints for future physical modeling. Initial comparisons to STEREO/EUVI images of the cavity and streamer show that the model can provide a good fit to the data. This work is part of the effort of the International Space Science Institute International Team on Prominence Cavities

  10. Dissipative preparation of entanglement in optical cavities

    DEFF Research Database (Denmark)

    Kastoryano, Michael James; Reiter, Florentin; Sørensen, Anders Søndberg

    2011-01-01

    We propose a novel scheme for the preparation of a maximally entangled state of two atoms in an optical cavity. Starting from an arbitrary initial state, a singlet state is prepared as the unique fixed point of a dissipative quantum dynamical process. In our scheme, cavity decay is no longer...

  11. Inertial confinement fusion reactor cavity phenomena

    International Nuclear Information System (INIS)

    Bohachevsky, I.O.; Hafer, J.F.; Devaney, J.J.; Pendergrass, J.H.

    1978-01-01

    Cavity phenomena in Inertial Confinement Fusion (ICF) are created by the interaction of energy released by the fuel pellet microexplosion with the medium inside the reactor cavity. The ambient state of the medium in ICF reactor cavities is restricted primarily by its effects on laser beam propagation and on the fuel pellet trajectory. Therefore, a relatively wide choice of ambient conditions can be exploited to gain first-wall protection and advantages in energy extraction. Depending on the choice of ambient cavity conditions and on fuel pellet design, a variety of physical phenomena may develop and dominate the ICF reactor cavity design. Because of the cavity phenomena, the forms of energy released by the fuel-pellet microexplosion are modified before reaching the first wall, thus giving rise to different cavity design problems. The types of cavity phenomena encountered in the conceptual design of ICF reactors are examined, the approaches available for their modeling and analysis are discussed, and some results are presented. Most phenomena are sufficiently well understood to permit valid engineering assessments of the proposed ICF reactor concepts

  12. Escherichia coli Administered into Pig Amniotic Cavity Appear in Fetal Airways and Attract Macrophages into Fetal Lungs

    Czech Academy of Sciences Publication Activity Database

    Šplíchal, Igor; Trebichavský, Ilja; Šplíchalová, A.; Sedláčková, Lenka; Zahradníčková, Marie

    2002-01-01

    Roč. 51, - (2002), s. 523-528 ISSN 0862-8408 R&D Projects: GA ČR GA524/99/0518 Keywords : intraamniotic infection * escherichia coli * pig Subject RIV: EE - Microbiology, Virology Impact factor: 0.984, year: 2002

  13. Tooth structure and fracture strength of cavities

    DEFF Research Database (Denmark)

    Mondelli, José; Sene, Fábio; Ramos, Renata Pereira

    2007-01-01

    This study evaluated, in vitro, the loss of tooth substance after cavity preparation for direct and indirect restorations and its relationship with fracture strength of the prepared teeth. Sixty sound human maxillary first premolars were assigned to 6 groups (n=10). MOD direct composite cavities......) or 1/2 (Groups III and VI) of the intercuspal distance. Teeth were weighed (digital balance accurate to 0.001 g) before and after preparation to record tooth substance mass lost during cavity preparation. The prepared teeth were submitted to occlusal loading to determine their fracture strength using...... a universal testing machine at a crosshead speed of 0.5 mm/min. Data were analyzed by two-way ANOVA and Tukey test (alpha= 0.05). 1/4-inlay cavities had higher percent mean mass loss (9.71%) than composite resin cavities with the same width (7.07%). 1/3-inlay preparations also produced higher percent mean...

  14. Fiber cavities with integrated mode matching optics.

    Science.gov (United States)

    Gulati, Gurpreet Kaur; Takahashi, Hiroki; Podoliak, Nina; Horak, Peter; Keller, Matthias

    2017-07-17

    In fiber based Fabry-Pérot Cavities (FFPCs), limited spatial mode matching between the cavity mode and input/output modes has been the main hindrance for many applications. We have demonstrated a versatile mode matching method for FFPCs. Our novel design employs an assembly of a graded-index and large core multimode fiber directly spliced to a single mode fiber. This all-fiber assembly transforms the propagating mode of the single mode fiber to match with the mode of a FFPC. As a result, we have measured a mode matching of 90% for a cavity length of ~400 μm. This is a significant improvement compared to conventional FFPCs coupled with just a single mode fiber, especially at long cavity lengths. Adjusting the parameters of the assembly, the fundamental cavity mode can be matched with the mode of almost any single mode fiber, making this approach highly versatile and integrable.

  15. Statistics of magnetoconductance in ballistic cavities

    International Nuclear Information System (INIS)

    Yang, X.; Ishio, H.; Burgdoerfer, J.

    1995-01-01

    The statistical properties of magnetoconductance in ballistic microcavities are investigated numerically. The distribution of conductance for chaotic cavities is found to follow the renormalized Porter-Thomas distribution suggested by random-matrix theory for the Gaussian ensemble while the conductance distribution of regular cavities in magnetic fields is nonuniversal and shifted towards the maximum value for a given number of open channels. The renormalized Porter-Thomas distribution implies a universal dependence of fluctuation amplitude on the mean conductance for chaotic cavities in the absence of time-reversal symmetry. The fluctuation amplitude for regular cavities is found to be larger than the saturation value of the fluctuation amplitude of chaotic cavities predicted by random-matrix theory. The change of the mean conductance as a function of the external magnetic field is consistent with semiclassical predictions

  16. New achievements in RF cavity manufacturing

    International Nuclear Information System (INIS)

    Lippmann, G.; Pimiskern, K.; Kaiser, H.

    1993-01-01

    Dornier has been engaged in development, manufacturing and testing of Cu-, Cu/Nb- and Nb-cavities for many years. Recently, several different types of RF cavities were manufactured. A prototype superconducting (s.c.) B-Factory accelerating cavity (1-cell, 500 MHz) was delivered to Cornell University, Laboratory of Nuclear Studies. A second lot of 6 s.c. cavities (20-cell, 3000 MHz) was fabricated on contract from Technical University of Darmstadt for the S-DALINAC facility. Finally, the first copper RF structures (9-cell, 1300 MHz) for TESLA were finished and delivered to DESY, two s.c. niobium structures of the same design are in production. Highlights from the manufacturing processes of these cavities are described and first performance results will be reported

  17. Iodine labelled pyrethroids, their chemical preparation and their application to radioimmunoassays. Pyrethrinoides marques a l'iode, leur procede de preparation et leur application aux dosages radioimmunologiques

    Energy Technology Data Exchange (ETDEWEB)

    Demoute, J.P.; Touer, G.; Mouren, M.

    1987-07-31

    This invention deals with iodine 125 or iodine 131 labelled pyrethroids, their chemical preparations and their application to radioimmunoassay for the determination of pyrethroids (deltamethrin) in human, or animal body fluids.

  18. Luminescent photonic crystal cavities for fiber-optic sensors, coupled dissimilar cavities and optofluidics

    Science.gov (United States)

    Dündar, Mehmet A.; Wang, Bowen; Siahaan, Timothy; Voorbraak, Joost A. M.; Speijcken, Noud W. L.; Nötzel, Richard; van der Hoek, Marinus J.; He, Sailing; Fiore, Andrea; Van der Heijden, Rob W.

    2012-06-01

    Photonic crystal (PhC) cavities made in broadband luminescent material offer attractive possibilities for flexible active devices. The luminescence enables the cavity to operate as an autonomous entity. New applications of this property are demonstrated for cavities made in the InGaAsP underetched semiconductor membrane with embedded InAs Quantum Dots that emit in the range of 1400-1600 nm. Planar photonic crystal membrane nanocavities were released from the parent chip by mechanical nanomanipulation. The released cavity particle could be bonded on an arbitrary surface, which was exploited to make a novel fiber-optic tip sensor with a PhC cavity attached to the tip. A single mode from a short cavity is shown to couple simultaneously to at least three cavity modes of a long cavity, as concluded from level anticrossing data when the small cavity was photothermally tuned. Reconfigurable and movable cavities were created by locally varying the infiltration status by liquid oil near a PhC waveguide or defect cavity. Liquid was displaced locally on a micron scale using capillary force effects or laser-induced evaporation and condensation phenomena.

  19. Cavity solitons and localized patterns in a finite-size optical cavity

    Energy Technology Data Exchange (ETDEWEB)

    Kozyreff, G. [Optique Nonlineaire Theorique, Universite Libre de Bruxelles (U.L.B.), CP 231 (Belgium); Gelens, L. [Applied Physics Research Group (APHY), Vrije Universiteit Brussel (Belgium)

    2011-08-15

    In appropriate ranges of parameters, laser-driven nonlinear optical cavities can support a wide variety of optical patterns, which could be used to carry information. The intensity peaks appearing in these patterns are called cavity solitons and are individually addressable. Using the Lugiato-Lefever equation to model a perfectly homogeneous cavity, we show that cavity solitons can only be located at discrete points and at a minimal distance from the edges. Other localized states which are attached to the edges are identified. By interpreting these patterns in an information coding frame, the information capacity of this dynamical system is evaluated. The results are explained analytically in terms of the the tail characteristics of the cavity solitons. Finally, the influence of boundaries and of cavity imperfections on cavity solitons are compared.

  20. Cancer of the oral cavity

    International Nuclear Information System (INIS)

    Wang, C.C.

    1987-01-01

    Squamous cell carcinomas of the oral cavity are curable. When early tumor (T1 and T2) is diagnosed and treated, cure rates by surgery or irradiation are high. The choice of therapeutic modalities for these lesions is complex and depends on the site of origin and size of the tumor, the presence or absence of nodal metastases, and the age, physical, medical, and socioeconomic status of the patient. Other factors include the willingness of the patient to return for a protracted course of radiation therapy, the skill of the physician, and the relative morbidity and cosmesis of the two forms of treatment. In general, surgery may be considered for early (T1) lesions if the deformity resulting from surgery is minimal. If resection involves major morbidity, such as a deformity that alters cosmesis or the function of the speech and swallowing mechanisms, then radiation therapy is preferred. For medium-sized (T2) tumors, superficial radiation therapy is the treatment of choice, for it controls the disease and preserves normal function and anatomy. Surgery is reserved for radiation failures. Extensive disease (T3 and T4) often associated with bone and muscle involvement and cervical lymph node metastases is rarely curable by radiation therapy or surgery alone; a combined approach using radiation therapy and surgery is therefore the procedure of choice

  1. LEP superconducting accelerating cavity module

    CERN Multimedia

    1995-01-01

    With its 27-kilometre circumference, the Large Electron-Positron (LEP) collider was the largest electron-positron accelerator ever built. The excavation of the LEP tunnel was Europe’s largest civil-engineering project prior to the Channel Tunnel. Three tunnel-boring machines started excavating the tunnel in February 1985 and the ring was completed three years later. In its first phase of operation, LEP consisted of 5176 magnets and 128 accelerating cavities. CERN’s accelerator complex provided the particles and four enormous detectors, ALEPH, DELPHI, L3 and OPAL, observed the collisions. LEP was commissioned in July 1989 and the first beam circulated in the collider on 14 July. The collider's initial energy was chosen to be around 91 GeV, so that Z bosons could be produced. The Z boson and its charged partner the W boson, both discovered at CERN in 1983, are responsible for the weak force, which drives the Sun, for example. Observing the creation and decay of the short-lived Z boson was a critical test of...

  2. The MEDICI reactor cavity model

    International Nuclear Information System (INIS)

    Bergeron, K.D.; Trebikock, W.

    1983-01-01

    The MEDICI reactor cavity model is currently under development with the goal of providing a flexible, relatively realistic treatment of ex-vessel severe accident phenomena suitable for large system codes like CONTAIN and MELCOR. The code is being developed with an emphasis on top-down design, to facilitate adaptability and multiple applications. A brief description of the overall code structure is provided. One of the key new models is then described in more detail. This is a dynamic quench model for debris beds. An example calculation using this model is presented. The question of whether it is necessary to consider the simultaneous motion of the quench front and ablation of the concrete is addressed with some scoping models. It is found that for realistic parameters and coolable beds, concrete ablation is too slow a process to be important on the quenching time scale. Remelt in the dry zone, however, is found to be potentially important on this time scale, so quench and remelt are considered simultaneously

  3. Hydroforming of Tesla Cavities at Desy

    International Nuclear Information System (INIS)

    Singer, W.; Kaiser, H.; Singer, X.; Gonin, I.; Zhelezov, I.; Khabibullin, T.; Kneisel, P.; Saito, K.

    2000-01-01

    Since several years the development of seamless niobium cavity fabrication by hydro forming is being pursued at DESY. This technique offers the possibility of lower cost of fabrication and perhaps better rf performance of the cavities because of the elimination of electron-beam welds, which in the standard fabrication technique have sometimes lead to inferior cavity performance due to defects. Several single cell 1300 MHz cavities have been formed from high purity seamless niobium tubes, which are under computer control expanded with internal pressure while simultaneously being swaged axially. The seamless tubes have been made by either back extrusion and flow forming or by spinning or deep drawing. Standard surface treatment techniques such as high temperature post purification, buffered chemical polishing (BCP), electropolishing (EP) and high pressure ultra pure water rinsing (HPR) have been applied to these cavities. The cavities exhibited high Q - values of 2 x 10 10 at 2K and residual resistances as low as 3 n(Omega) after the removal of a surface layer of app. 100 (micro)m by BCP. Surprisingly, even at high gradients up to the maximum measured values of E acc ∼ 33 MV/m the Q-value did not decrease in the absence of field emission as often observed. After electropolishing of additional 100 (micro)m one of the cavities reached an accelerating gradient of E acc (ge) 42 MV/m

  4. Preparation and handling of superconducting RF cavities

    International Nuclear Information System (INIS)

    Furuya, Takaaki

    1990-01-01

    The present paper outlines the recent preparation methods for superconducting cavities used in various laboratories and universities, and reports the problems of the cavity fabrication at KEK as an example of mass production. Preparation and handling are first addressed, focusing on material, fabrication, surface treatment, rinsing, clean environment, and heat treatment. Cavity production at KEK is then described, centering on defects on the surface and clean environments. Field gradients of more than 20 MV/m have been obtained by 1.5-3 GHz single cavities, for multi-cell cavities Eacc of 10 MV/m are available at any frequency range. The successful construction of thirty-two cavities for TRISTAN at KEK is due to the careful checking of the surface and quality control of all processes against the surface defects and contaminations. Eacc of 5 MV/m has been achieved by 94 % of the TRISTAN cavities at the first cold test, but 6 % of them had to be reworked because of the surface defects. These defects could not be detected by an X-ray photograph or visual inspections during the fabrication processes. (N.K.)

  5. Passive control of supersonic cavity flowfields

    Science.gov (United States)

    Chokani, N.; Kim, I.

    1991-01-01

    A computational investigation has been conducted to study the effect and mechanisms of the passive control of a supersonic flow over a rectangular two-dimensional cavity. The passive control was included through the use of a porous surface over a vent chamber in the floor of the cavity. The passive control effectively suppressed the low-frequency pressure oscillations for the open type cavity, (length-to-depth ratio = 6.0). The mechanism for the suppression was observed to be the stabilization of the motion of the free shear layer. For the closed type cavity flow, (length-to-depth ratio = 17.5), the passive control modified the flowfield to nearly that of an open type cavity flow; further the cavity drag was reduced by a factor of four. The computational results of both cases showed good agreement with the available experimental data and the predictions of a semiempirical formula. This study demonstrates that the passive control concept can be used to improve the aerodynamic characteristics of open and closed cavity flowfields.

  6. The CEBAF separator cavity resonance control system

    International Nuclear Information System (INIS)

    M. Wissmann; C. Hovater; A. Guerra; T. Plawski

    2005-01-01

    The CEBAF energy upgrade will increase the maximum beam energy from 6 GeV to 12 GeV available to the experimental halls. RF deflection cavities (separators) are used to direct the electron beam to the three halls. The resulting increase in RF separator cavity gradient and subsequent increase in RF power needed for these higher energies will require the cavities to have active resonance control. Currently, at the present 4 to 6 GeV energies, the cavities are tuned mechanically and then stabilized with Low Conductivity Water (LCW) which is maintained at a constant temperature of 95 Fahrenheit. This approach is no longer feasible and an active resonance control system that controls both water temperature and flow has been designed and built. The system uses a commercial PLC with embedded PID controls to regulate water temperature and flow to the cavities. The system allows the operator to remotely adjust temperature/flow and consequently cavity resonance for the full range of beam energies. Ultimately, closed loop control will be maintained by monitoring each cavity's reflected power. This paper describes this system

  7. Forward Modeling of a Coronal Cavity

    Science.gov (United States)

    Kucera, T. A.; Gibson, S. E.; Schmit, D. J.

    2011-01-01

    We apply a forward model of emission from a coronal cavity in an effort to determine the temperature and density distribution in the cavity. Coronal cavities are long, low-density structures located over filament neutral lines and are often seen as dark elliptical features at the solar limb in white light, EUV and X-rays. When these structures erupt they form the cavity portions of CMEs The model consists of a coronal streamer model with a tunnel-like cavity with elliptical cross-section and a Gaussian variation of height along the tunnel length. Temperature and density can be varied as a function of altitude both in the cavity and streamer. We apply this model to a cavity observed in Aug. 2007 by a wide array of instruments including Hinode/EIS, STEREO/EUVI and SOHO/EIT. Studies such as these will ultimately help us understand the the original structures which erupt to become CMEs and ICMES, one of the prime Solar Orbiter objectives.

  8. Superconducting cavity driving with FPGA controller

    Energy Technology Data Exchange (ETDEWEB)

    Czarski, T.; Koprek, W.; Pozniak, K.T.; Romaniuk, R.S. [Warsaw Univ. of Technology (Poland); Simrock, S.; Brand, A. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Chase, B.; Carcagno, R.; Cancelo, G. [Fermi National Accelerator Lab., Batavia, IL (United States); Koeth, T.W. [Rutgers - the State Univ. of New Jersey, NJ (United States)

    2006-07-01

    The digital control of several superconducting cavities for a linear accelerator is presented. The laboratory setup of the CHECHIA cavity and ACC1 module of the VU-FEL TTF in DESY-Hamburg have both been driven by a Field Programmable Gate Array (FPGA) based system. Additionally, a single 9-cell TESLA Superconducting cavity of the FNPL Photo Injector at FERMILAB has been remotely controlled from WUT-ISE laboratory with the support of the DESY team using the same FPGA control system. These experiments focused attention on the general recognition of the cavity features and projected control methods. An electrical model of the resonator was taken as a starting point. Calibration of the signal path is considered key in preparation for the efficient driving of a cavity. Identification of the resonator parameters has been proven to be a successful approach in achieving required performance; i.e. driving on resonance during filling and field stabilization during flattop time while requiring reasonable levels of power consumption. Feed-forward and feedback modes were successfully applied in operating the cavities. Representative results of the experiments are presented for different levels of the cavity field gradient. (orig.)

  9. Design of the Advanced LIGO recycling cavities.

    Science.gov (United States)

    Arain, Muzammil A; Mueller, Guido

    2008-07-07

    The current LIGO detectors will undergo an upgrade which is expected to improve their sensitivity and bandwidth significantly. These advanced gravitational-wave detectors will employ stable recycling cavities to better confine their spatial eigenmodes instead of the currently installed marginally stable power recycling cavity. In this letter we describe the general layout of the recycling cavities and give specific values for a first possible design. We also address the issue of mode mismatch due to manufacturing tolerance of optical elements and present a passive compensation scheme based upon optimizing the distances between optical elements.

  10. Interaction of IREB with a cavity

    International Nuclear Information System (INIS)

    Sawhney, R.; Mishra, Mamta; Purkayastha, A.D.; Rambabu, P.; Maheshwari, K.P.

    1991-01-01

    The propagation of an intense pulsed relativistic electron beam (IREB) through a cavity resonator is considered. The cavity gets shock excited. The electromagnetic fields so generated interact with the beam in such a way that the energy is transferred from the front of the beam to the back. As a result the beams gets energized but shortened in time. Analysis for the chosen dominant mode of the cavity viz. TMsub(010) is carried out. The induced electric field excited is calculated and the accelerating potential is estimated. The results are compared with the recent-experiments. (author). 5 refs., 1 fig

  11. Micro-Cavity Fluidic Dye Laser

    DEFF Research Database (Denmark)

    Helbo, Bjarne; Kristensen, Anders; Menon, Aric Kumaran

    2003-01-01

    We have successfully designed, fabricated and characterized a micro-cavity fluidic dye laser with metallic mirrors, which can be integrated with polymer based lab-on-a-chip microsystems without further processing steps. A simple rate-equation model is used to predict the average pumping power...... threshold for lasing as function of cavity-mirror reflectance, laser dye concentration and cavity length. The laser device is characterized using the laser dye Rhodamine 6G dissolved in ethanol. Lasing is observed, and the influence of dye concentration is investigated....

  12. Indirect coupling of magnons by cavity photons

    Science.gov (United States)

    Zare Rameshti, Babak; Bauer, Gerrit E. W.

    2018-01-01

    The interaction between two magnetic spheres in microwave cavities is studied by Mie scattering theory beyond the magnetostatic and rotating wave approximations. We demonstrate that two spatially separated dielectric and magnetic spheres can be strongly coupled over a long distance by the electric field component of standing microwave cavity modes. The interactions split acoustical (dark) and optical (bright) modes in a way that can be mapped on a molecular orbital theory of the hydrogen molecule. Breaking the symmetry by assigning different radii to the two spheres introduces "ionic" character to the magnonic bonds. These results illustrate the coherent and controlled energy exchange between objects in microwave cavities.

  13. Analysis of dual coupler nested coupled cavities.

    Science.gov (United States)

    Adib, George A; Sabry, Yasser M; Khalil, Diaa

    2017-12-01

    Coupled ring resonators are now forming the basic building blocks in several optical systems serving different applications. In many of these applications, a small full width at half maximum is required, along with a large free spectral range. In this work, a configuration of passive coupled cavities constituting dual coupler nested cavities is proposed. A theoretical study of the configuration is presented allowing us to obtain analytical expressions of its different spectral characteristics. The transfer function of the configuration is also used to generate design curves while comparing these results with analytical expressions. Finally, the configuration is compared with other coupled cavity configurations.

  14. Cavity Pressure Behaviour in Micro Injection Moulding

    DEFF Research Database (Denmark)

    Griffiths, C.A.; Dimov, S.S.; Scholz, S.

    2010-01-01

    Process monitoring of micro injection moulding (µIM) is of crusial importance to analyse the effect of different parameter settings on the process and to assess its quality. Quality factors related to cavity pressure can provide useful information directly connected with the dyanmics of the process...... as well as with the filling of the cavity by the polymer melt. In this paper, two parameters derived from cavity pressure over time (i.e. pressure work). The influence of four µIM parameters (melt temperature, mould temperature, injection speed, aand packing pressure) on the two pressure-related outputs...

  15. 32 CFR 637.11 - Authority to administer oaths.

    Science.gov (United States)

    2010-07-01

    ... ENFORCEMENT AND CRIMINAL INVESTIGATIONS MILITARY POLICE INVESTIGATION Investigations § 637.11 Authority to... administer oaths to military personnel who are subject to the UCMJ. The authority to administer oaths to...

  16. Upgraded cavities for the positron accumulator ring of the APS

    International Nuclear Information System (INIS)

    Kang, Y.W.; Jiang, X.; Mangra, D.

    1997-01-01

    Upgraded versions of cavities for the APS positron accumulator ring (PAR) have been built and are being tested. Two cavities are in the PAR: a fundamental 9.8-MHz cavity and a twelfth harmonic 117.3-MHz cavity. Both cavities have been manufactured for higher voltage operation with improved Q-factors, reliability, and tuning capability. Both cavities employ current-controlled ferrite tuners for control of the resonant frequency. The harmonic cavity can be operated in either a pulsed mode or a CW mode. The rf properties of the cavities are presented

  17. Radiotherapy for Oral Cavity Cancer

    International Nuclear Information System (INIS)

    Shim, Jae Won

    1993-01-01

    Eighty five patients of oral cavity cancer, treated with radiation at the Department of Therapeutic Radiology, Korea Cancer Center Hospital, during the period from March 1985 to September 1990 were analyzed retrospectively. Among 85 patients, 37 patients were treated with radiation only and 48 patients were treated with radiation following surgery And 70 patients received external irradiation only by 60 Co with or without electron, the others were 7 patients for external irradiation plus interstitial implantation and 8 patients for external irradiation plus oral cone electron therapy. Primary sites were mobile tongue for 40 patients, mouth floor for 17 patients, palate for 12 patients, gingiva including retromolar trigone for 10 patients, buccal mucosa for 5 patients, and lip for 1 patient. According to pathologic classification, squamous cell carcinoma was the most common (77 patients). According to AJC TNM stage, stage I + II were 28 patients and stage III + IV were 57 patients. Acturial overall survival rate at 3 years was 43.9%, 3 year survival rates were 60.9% for stage I + II, and 23.1% for stage III + IV, respectively. As a prognostic factor, primary T stage was a significant factor (p<0.01). The others, age, location, lymph node metastasis, surgery, radiation dose, and cell differentiation were not statistically significant. Among those factors, radiation plus surgery was more effective than radiation only in T3 + T4 or in any N stage although it was not statistically sufficient(p<0.1). From those results, it was conclusive that definitive radiotherapy was more effective than surgery especially in the view of pertaining of anatomical integrity and function in early stage, and radiation plus surgery was considered to be better therapeutic tool in advanced stage

  18. High-Q ferrite-tuned cavity

    International Nuclear Information System (INIS)

    Carlini, R.D.; Thiessen, H.A.; Potter, J.M.; Earley, L.M.

    1983-01-01

    Rapid cycling proton synchrotrons, such as the proposed LAMPF II accelerator, require approximately 10 MV per turn rf with 17% tuning range near 50 MHz. The traditional approach to ferrite-tuned cavities uses a ferrite which is longitudinally biased (rf magnetic field parallel to bias field). This method leads to unacceptably high losses in the ferrite. At Los Alamos, we are developing a cavity with transverse bias (rf magnetic field perpendicular to the bias field) that makes use of the tensor permeability of the ferrite. Initial tests of a small (10-cm-diam) quarter-wave singly re-entrant cavity tuned by several different ferrites indicate that the losses in the ferrite can be made negligible compared with the losses due to the surface resistivity of the copper cavity

  19. Molding of L band niobium superconductor cavity

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Hitoshi; Funahashi, Yoshisato; Saito, Kenji; Noguchi, Shuichi; Koizumi, Susumu [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan)

    1995-07-01

    A cavity to produce high accelerating electron field was developed. The L-band (1.3 GHz) niobium superconductor unit cell cavity was ellipsoid with {phi}217.3 mm outer diameter and 2.5 mm thickness and consisted of two pieces of half cell, two beam pipes and flange. A deep drawing process was adapted. In spite of the first trial manufacture, each good cavity was obtained. Characteristic properties of niobium materials, molding method of cavity, extension of sheet after molding, production of beam pipe, accuracy and the cost were explained. Niobium materials. showed tensile strength 15.6 kg/mm{sup 2}, load-carrying capacity 4.1 kg/mm{sup 2}, density 8.57, extension 42.5% and RRR (resistance residual ratio){>=}200. (S.Y.)

  20. section of an accelerating cavity from LEP

    CERN Multimedia

    This is a section of an accelerating cavity from LEP, cut in half to show the layer of niobium on the inside. Operating at 4.2 degrees above absolute zero, the niobium is superconducting and carries an accelerating field of 6 million volts per metre with negligible losses. Each cavity has a surface of 6 m2. The niobium layer is only 1.2 microns thick, ten times thinner than a hair. Such a large area had never been coated to such a high accuracy. A speck of dust could ruin the performance of the whole cavity so the work had to be done in an extremely clean environment. These challenging requirements pushed European industry to new achievements. 256 of these cavities are now used in LEP to double the energy of the particle beams.

  1. Degreasing and cleaning superconducting RF Niobium cavities

    Energy Technology Data Exchange (ETDEWEB)

    Rauchmiller, Michael; Kellett, Ron; /Fermilab

    2011-09-01

    The purpose and scope of this report is to detail the steps necessary for degreasing and cleaning of superconducting RF Niobium cavities in the A0 clean room. It lists the required equipment and the cleaning procedure.

  2. Circuit QED with 3D cavities

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Edwar; Baust, Alexander; Zhong, Ling; Gross, Rudolf [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, Garching (Germany); Physik-Department, TU Muenchen, Garching (Germany); Nanosystems Initiative Munich (NIM), Muenchen (Germany); Anderson, Gustav; Wang, Lujun; Eder, Peter; Fischer, Michael; Goetz, Jan; Haeberlein, Max; Schwarz, Manuel; Wulschner, Karl Friedrich; Deppe, Frank; Fedorov, Kirill; Huebl, Hans; Menzel, Edwin [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, Garching (Germany); Physik-Department, TU Muenchen, Garching (Germany); Marx, Achim [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, Garching (Germany)

    2015-07-01

    In typical circuit QED systems on-chip superconducting qubits are coupled to integrated coplanar microwave resonators. Due to the planar geometry, the resonators are often a limiting factor regarding the total coherence of the system. Alternatively, similar hybrid systems can be realized using 3D microwave cavities. Here, we present design considerations for the 3D microwave cavity as well as the superconducting transmon qubit. Moreover, we show experimental data of a high purity aluminum cavity demonstrating quality factors above 1.4 .10{sup 6} at the single photon level and a temperature of 50 mK. Our experiments also demonstrate that the quality factor is less dependent on the power compared to planar resonator geometries. Furthermore, we present strategies for tuning both the cavity and the qubit individually.

  3. Cavity-Enhanced Transport of Charge

    Science.gov (United States)

    Hagenmüller, David; Schachenmayer, Johannes; Schütz, Stefan; Genes, Claudiu; Pupillo, Guido

    2017-12-01

    We theoretically investigate charge transport through electronic bands of a mesoscopic one-dimensional system, where interband transitions are coupled to a confined cavity mode, initially prepared close to its vacuum. This coupling leads to light-matter hybridization where the dressed fermionic bands interact via absorption and emission of dressed cavity photons. Using a self-consistent nonequilibrium Green's function method, we compute electronic transmissions and cavity photon spectra and demonstrate how light-matter coupling can lead to an enhancement of charge conductivity in the steady state. We find that depending on cavity loss rate, electronic bandwidth, and coupling strength, the dynamics involves either an individual or a collective response of Bloch states, and we explain how this affects the current enhancement. We show that the charge conductivity enhancement can reach orders of magnitudes under experimentally relevant conditions.

  4. Cavity squeezing by a quantum conductor

    International Nuclear Information System (INIS)

    Mendes, Udson C; Mora, Christophe

    2015-01-01

    Hybrid architectures integrating mesoscopic electronic conductors with resonant microwave cavities have a great potential for investigating unexplored regimes of electron–photon coupling. In this context, producing nonclassical squeezed light is a key step towards quantum communication with scalable solid-state devices. Here we show that parametric driving of the electronic conductor induces a squeezed steady state in the cavity. We find that squeezing properties of the cavity are essentially determined by the electronic noise correlators of the quantum conductor. In the case of a tunnel junction, we predict that squeezing is optimized by applying a time-periodic series of quantized δ—peaks in the bias voltage. For an asymmetric quantum dot, we show that a sharp Leviton pulse is able to achieve perfect cavity squeezing. (paper)

  5. Design of an optical cavity for gravimetry

    Science.gov (United States)

    Billion Reyes, M. S.; Lopez-Vazquez, A.; Pimenta, W. M.; Gonzalez, M. A.; Franco-Villafane, J. A.; Gomez, E.

    2017-04-01

    Atomic interferometry is a widely used method to perform precision measurements of accelerations. We enhance the interferometric signal by adding an optical cavity around the free-falling atoms inside of a vacuum chamber. We use a bow-tie configuration to support a traveling wave and avoid spatial fluctuations in the light shift. To induce collective behavior (entangled state), we design the optical cavity with a cooperativity factor higher than one. We present the characterization of an optical cavity with a maximized beam waist to reach homogeneous illumination of the atomic cloud. The mirrors have high reflectivity (R =99.999%) at 780 nm, in a non-confocal arrangement so that we can excite transverse modes independently or simultaneously. We describe our progress to achieve a transverse mode closer to a flat-top and a cavity design that fits our geometrical restrictions. Funding from CONACYT.

  6. Mechanical design and fabrication of power feed cavity test setup

    International Nuclear Information System (INIS)

    Ghodke, S.R.; Dhavle, A.S.; Sharma, Vijay; Sarkar, Shreya; Kumar, Mahendra; Nayak, Susanta; Barnwal, Rajesh; Jayaprakash, D.; Mondal, J.; Nimje, V.T.; Mittal, K.C.; Gantayet, L.M.

    2013-01-01

    Power feed cavity set up consists of nine number of accelerating cavity and eight numbers of coupling cavity for testing of power feed cavity with coupling flange for 2856 MHz S band standing wave coupled cavity linac. When we are assembling the cavity and applying the pressure, its resonance frequency changes with applied pressure/load. After some critical pressure/load frequency change becomes negligible or zero. This set up will be used to find out assembly performance of power feed cavity and its coupler. Top four cavity or eight half cells as well as bottom four cavity or eight half cells will be brazed separately. Power feed cavity will be sandwiched between this two brazed cavity assemblies. This paper discuss about linear motion bush, linear motion rod, load cell, hydraulic actuator, power pack, stepper motor PLC control, jig boring, alignment, tolerances and assembly procedure for this test setup. (author)

  7. HOM power in FCC-ee cavities

    CERN Document Server

    Karpov, Ivan; Chapochnikova, Elena

    2018-01-01

    This Note summarizes the results of the power loss calculations for FCC-ee machines with 400.79 MHz cavity options. The requirements for the single-cell cavity design and for the operation with beam are obtained from the results for the high-current FCC-ee machine (Z). For other machines the power loss is sufficiently low and can be absorbed and extracted by foreseen HOM couplers.

  8. Cavity-Assisted Quantum Bath Engineering

    Science.gov (United States)

    Murch, K. W.; Vool, U.; Zhou, D.; Weber, S. J.; Girvin, S. M.; Siddiqi, I.

    2012-11-01

    We demonstrate quantum bath engineering for a superconducting artificial atom coupled to a microwave cavity. By tailoring the spectrum of microwave photon shot noise in the cavity, we create a dissipative environment that autonomously relaxes the atom to an arbitrarily specified coherent superposition of the ground and excited states. In the presence of background thermal excitations, this mechanism increases state purity and effectively cools the dressed atom state to a low temperature.

  9. Performance experience with the CEBAF SRF cavities

    Energy Technology Data Exchange (ETDEWEB)

    Reece, C.; Benesch, J.; Drury, M.; Hovater, C.; Mammosser, J.; Preble, J.

    1995-12-31

    The full complement of 169 pairs of niobium superconducting cavities has been installed in the CEBAF accelerator. This paper surveys the performance characteristics of these cavities in vertical tests, commissioning in the tunnel, and operational experience to date. Although installed performance exceeds specifications, and 3.2 GeV beam has been delivered on target, present systems do not consistently preserve the high performance obtained in vertical dewar tests as operational capability. Principal sources of these limitations are discussed.

  10. Ultrasensitive and broadband magnetometry with cavity optomechanics

    DEFF Research Database (Denmark)

    Li, Bei-Bei; Bulla, Douglas; Bilek, Jan

    2017-01-01

    We achieved sensitivity of 30 pT/Hz1/2 and working bandwidth larger than 100 MHz, using cavity optomechanical magnetometry, and also demonstrated quantum light enhanced sensitivity in such a magnetometer.......We achieved sensitivity of 30 pT/Hz1/2 and working bandwidth larger than 100 MHz, using cavity optomechanical magnetometry, and also demonstrated quantum light enhanced sensitivity in such a magnetometer....

  11. Quantum cavities with alternating boundary conditions

    Science.gov (United States)

    Facchi, Paolo; Garnero, Giancarlo; Ligabò, Marilena

    2018-03-01

    We consider the quantum dynamics of a free nonrelativistic particle moving in a cavity and we analyze the effect of a rapid switching between two different boundary conditions. We show that this procedure induces, in the limit of infinitely frequent switchings, a new effective dynamics in the cavity related to a novel boundary condition. We obtain a dynamical composition law for boundary conditions which gives the emerging boundary condition in terms of the two initial ones.

  12. Early 500 MHz prototype LEP RF Cavity with superposed storage cavity

    CERN Multimedia

    CERN PhotoLab

    1981-01-01

    The principle of transferring the RF power back and forth between the accelerating cavity and a side-coupled storage cavity was demonstrated with this 500 MHz prototype. In LEP, the accelerating frequency was 352.2 MHz, and accelerating and storage cavities were consequently larger. See also 8002294, 8006061, 8407619X, and Annual Reports 1980, p.115; 1981, p.95; 1985, vol.I, p.13.

  13. Study of CSR longitudinal bunch compression cavity

    International Nuclear Information System (INIS)

    Yin Dayu; Li Peng; Liu Yong; Xie Qingchun

    2009-01-01

    The scheme of longitudinal bunch compression cavity for the Cooling Storage Ring (CSR)is an important issue. Plasma physics experiments require high density heavy ion beam and short pulsed bunch,which can be produced by non-adiabatic compression of bunch implemented by a fast compression with 90 degree rotation in the longitudinal phase space. The phase space rotation in fast compression is initiated by a fast jump of the RF-voltage amplitude. For this purpose, the CSR longitudinal bunch compression cavity, loaded with FINEMET-FT-1M is studied and simulated with MAFIA code. In this paper, the CSR longitudinal bunch compression cavity is simulated and the initial bunch length of 238 U 72+ with 250 MeV/u will be compressed from 200 ns to 50 ns.The construction and RF properties of the CSR longitudinal bunch compression cavity are simulated and calculated also with MAFIA code. The operation frequency of the cavity is 1.15 MHz with peak voltage of 80 kV, and the cavity can be used to compress heavy ions in the CSR. (authors)

  14. The CEBAF Separator Cavity Resonance Control System

    CERN Document Server

    Wissmann, Mark J; Hovater, Curt; Plawski, Tomasz

    2005-01-01

    The CEBAF energy upgrade from 6 GeV to 12GeV will increase the range of beam energies available to the experimental halls. RF deflection cavities (separators) are used to direct the electron beam to the three experimental halls. Consequently with the increase in RF separator cavity gradient needed for the higher energies, RF power will also increase requiring the cavities to have active resonance control. At the 6 GeV energy, the cavities are tuned mechanically and then stabilized with Low Conductivity Water (LCW), which is maintained at constant temperature of 95o Fahrenheit. This is no longer feasible and an active resonance control system, that controls both water temperature and flow has been built. The system uses a commercial PLC with embedded PID controls to control water temperature and flow to the cavities. The system allows the operator to remotely adjust temperature/flow and consequently cavity resonance for the full range of beam energies. Ultimately closed loop control will be maintained by monit...

  15. Estimating tree cavity distributions from historical FIA data

    Science.gov (United States)

    Mark D. Nelson; Charlotte. Roy

    2012-01-01

    Tree cavities provide important habitat features for a variety of wildlife species. We describe an approach for using historical FIA data to estimate the number of trees containing cavities during the 1990s in seven states of the Upper Midwest. We estimated a total of 280 million cavity-containing trees. Iowa and Missouri had the highest percentages of cavity-...

  16. Soliton laser: A computational two-cavity model

    DEFF Research Database (Denmark)

    Berg, P.; If, F.; Christiansen, Peter Leth

    1987-01-01

    An improved computational two-cavity model of the soliton laser proposed and designed by Mollenauer and Stolen [Opt. Lett. 9, 13 (1984)] is obtained through refinements of (i) the laser cavity model, (ii) the pulse propagation in the fiber cavity, and (iii) the coupling between the two cavities...

  17. RF BREAKDOWN STUDIES USING PRESSURIZED CAVITIES

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland

    2014-09-21

    Many present and future particle accelerators are limited by the maximum electric gradient and peak surface fields that can be realized in RF cavities. Despite considerable effort, a comprehensive theory of RF breakdown has not been achieved and mitigation techniques to improve practical maximum accelerating gradients have had only limited success. Part of the problem is that RF breakdown in an evacuated cavity involves a complex mixture of effects, which include the geometry, metallurgy, and surface preparation of the accelerating structures and the make-up and pressure of the residual gas in which plasmas form. Studies showed that high gradients can be achieved quickly in 805 MHz RF cavities pressurized with dense hydrogen gas, as needed for muon cooling channels, without the need for long conditioning times, even in the presence of strong external magnetic fields. This positive result was expected because the dense gas can practically eliminate dark currents and multipacting. In this project we used this high pressure technique to suppress effects of residual vacuum and geometry that are found in evacuated cavities in order to isolate and study the role of the metallic surfaces in RF cavity breakdown as a function of magnetic field, frequency, and surface preparation. One of the interesting and useful outcomes of this project was the unanticipated collaborations with LANL and Fermilab that led to new insights as to the operation of evacuated normal-conducting RF cavities in high external magnetic fields. Other accomplishments included: (1) RF breakdown experiments to test the effects of SF6 dopant in H2 and He gases with Sn, Al, and Cu electrodes were carried out in an 805 MHz cavity and compared to calculations and computer simulations. The heavy corrosion caused by the SF6 components led to the suggestion that a small admixture of oxygen, instead of SF6, to the hydrogen would allow the same advantages without the corrosion in a practical muon beam line. (2) A

  18. High field conditioning of cryogenic RF cavities

    International Nuclear Information System (INIS)

    Cole, M.; Debiak, T.; Lom, C.; Shephard, W.; Sredniawski, J.

    1993-01-01

    Space-based and other related accelerators have conditioning and operation requirements that are not found in most machines. The use of cryogenic copper, relatively poor vacuum, and limited power storage and operating time put unusual demands on the high-field conditioning process and present some concerns. Two CW cryogenic engineering model open-quotes sparkerclose quotes cavities have been fabricated and tested to fairly high field levels. Tests included initial and repeated conditioning as well as sustained RF operations. The two cavities were an engineering model TDL and an engineering model RFQ. Both cavities operated at 425 MHz. The DTL was conditioned to 46 MV/m at 100% duty factor (CW) at cryogenic temperature. This corresponds to a gap voltage of 433 kV and a real estate accelerating gradient (energy gain/total cavity length) of 6.97 MV/m. The authors believe this to be record performance for cryo CW operation. During cryo pulsed operation, the same cavity reached 48 MV/m with 200 μsec pulses at 0.5% DF. The RFQ was conditioned to 30 MV/m CW at cryo, 85 kV gap voltage. During a brief period of cryo pulsed operation, the RFQ operated at 46 MV/m, or 125 kV gap voltage. Reconditioning experiments were performed on both cavities and no problems were encountered. It should be noted that the vacuum levels were not very stringent during these tests and no special cleanliness or handling procedures were followed. The results of these tests indicate that cavities can run CW without difficulty at cryogenic temperatures at normal conservative field levels. Higher field operation may well be possible, and if better vacuums are used and more attention is paid to cleanliness, much higher fields may be attainable

  19. Natural cavity characteristics and cavity bird abundance on West Virginia forested islands of the Ohio River

    Science.gov (United States)

    James T. Anderson; Karen A. Riesz

    2013-01-01

    Wildlife habitats connected with forested islands and their back channels (areas where commercial traffic is prohibited) on the Ohio River are valuable to diverse species. However, quantitative data on the importance of these areas to cavity-nesting birds are lacking. We compared cavity-nesting bird use and habitat between back and navigational channel sides of islands...

  20. Dispersive optomechanics: a membrane inside a cavity

    Energy Technology Data Exchange (ETDEWEB)

    Jayich, A M; Sankey, J C; Zwickl, B M; Yang, C; Thompson, J D; Girvin, S M; Harris, J G E [Department of Physics, Yale University, New Haven, CT (United States); Clerk, A A [Department of Physics, McGill University, Montreal (Canada); Marquardt, F [Department of Physics, Arnold-Sommerfeld-Center for Theoretical Physics and Center for Nanoscience, Muenchen (Germany)], E-mail: jack.harris@yale.edu

    2008-09-15

    We present the results of theoretical and experimental studies of dispersively coupled (or 'membrane in the middle') optomechanical systems. We calculate the linear optical properties of a high finesse cavity containing a thin dielectric membrane. We focus on the cavity's transmission, reflection and finesse as a function of the membrane's position along the cavity axis and as a function of its optical loss. We compare these calculations with measurements and find excellent agreement in cavities with empty-cavity finesses in the range 10{sup 4}-10{sup 5}. The imaginary part of the membrane's index of refraction is found to be {approx}10{sup -4}. We calculate the laser cooling performance of this system, with a particular focus on the less-intuitive regime in which photons 'tunnel' through the membrane on a timescale comparable to the membrane's period of oscillation. Lastly, we present calculations of quantum non-demolition measurements of the membrane's phonon number in the low signal-to-noise regime where the phonon lifetime is comparable to the QND readout time.

  1. Cavity electromagnetically induced transparency with Rydberg atoms

    Science.gov (United States)

    Bakar Ali, Abu; Ziauddin

    2018-02-01

    Cavity electromagnetically induced transparency (EIT) is revisited via the input probe field intensity. A strongly interacting Rydberg atomic medium ensemble is considered in a cavity, where atoms behave as superatoms (SAs) under the dipole blockade mechanism. Each atom in the strongly interacting Rydberg atomic medium (87 Rb) follows a three-level cascade atomic configuration. A strong control and weak probe field are employed in the cavity with the ensemble of Rydberg atoms. The features of the reflected and transmitted probe light are studied under the influence of the input probe field intensity. A transparency peak (cavity EIT) is revealed at a resonance condition for small values of input probe field intensity. The manipulation of the cavity EIT is reported by tuning the strength of the input probe field intensity. Further, the phase and group delay of the transmitted and reflected probe light are studied. It is found that group delay and phase in the reflected light are negative, while for the transmitted light they are positive. The magnitude control of group delay in the transmitted and reflected light is investigated via the input probe field intensity.

  2. Multi-Mode Cavity Accelerator Structure

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Yong [Yale Univ., New Haven, CT (United States); Hirshfield, Jay Leonard [Omega-P R& D, Inc., New Haven, CT (United States)

    2016-11-10

    This project aimed to develop a prototype for a novel accelerator structure comprising coupled cavities that are tuned to support modes with harmonically-related eigenfrequencies, with the goal of reaching an acceleration gradient >200 MeV/m and a breakdown rate <10-7/pulse/meter. Phase I involved computations, design, and preliminary engineering of a prototype multi-harmonic cavity accelerator structure; plus tests of a bimodal cavity. A computational procedure was used to design an optimized profile for a bimodal cavity with high shunt impedance and low surface fields to maximize the reduction in temperature rise ΔT. This cavity supports the TM010 mode and its 2nd harmonic TM011 mode. Its fundamental frequency is at 12 GHz, to benchmark against the empirical criteria proposed within the worldwide High Gradient collaboration for X-band copper structures; namely, a surface electric field Esurmax< 260 MV/m and pulsed surface heating ΔTmax< 56 °K. With optimized geometry, amplitude and relative phase of the two modes, reductions are found in surface pulsed heating, modified Poynting vector, and total RF power—as compared with operation at the same acceleration gradient using only the fundamental mode.

  3. A spherical cavity model for quadrupolar dielectrics

    Science.gov (United States)

    Dimitrova, Iglika M.; Slavchov, Radomir I.; Ivanov, Tzanko; Mosbach, Sebastian

    2016-03-01

    The dielectric properties of a fluid composed of molecules possessing both dipole and quadrupole moments are studied based on a model of the Onsager type (molecule in the centre of a spherical cavity). The dielectric permittivity ɛ and the macroscopic quadrupole polarizability αQ of the fluid are related to the basic molecular characteristics (molecular dipole, polarizability, quadrupole, quadrupolarizability). The effect of αQ is to increase the reaction field, to bring forth reaction field gradient, to decrease the cavity field, and to bring forth cavity field gradient. The effects from the quadrupole terms are significant in the case of small cavity size in a non-polar liquid. The quadrupoles in the medium are shown to have a small but measurable effect on the dielectric permittivity of several liquids (Ar, Kr, Xe, CH4, N2, CO2, CS2, C6H6, H2O, CH3OH). The theory is used to calculate the macroscopic quadrupolarizabilities of these fluids as functions of pressure and temperature. The cavity radii are also determined for these liquids, and it is shown that they are functions of density only. This extension of Onsager's theory will be important for non-polar solutions (fuel, crude oil, liquid CO2), especially at increased pressures.

  4. CERN Developments for 704 MHz Superconducting Cavities

    CERN Document Server

    Capatina, O; Aviles Santillana, I; Arnau Izquierdo, G; Bonomi, R; Calatroni, S; Chambrillon, J; Gerigk, F; Garoby, R; Guinchard, M; Junginger, T; Malabaila, M; Marques Antunes Ferreira, L; Mikulas, S; Parma, V; Pillon, F; Renaglia, T; Schirm, K; Tardy, T; Therasse, M; Vacca, A; Valverde Alonso, N; Vande Craen, A

    2013-01-01

    The Superconducting Proton Linac (SPL) is an R&D effort coordinated by CERN in partnership with other international laboratories. It is aiming at developing key technologies for the construction of a multi-megawatt proton linac based on state-of-the-art RF superconducting technology, which would serve as a driver in new physics facilities for neutrinos and/or Radioactive Ion Beam (RIB). Amongst the main objectives of this R&D effort, is the development of 704 MHz bulk niobium beta=1 elliptical cavities, operating at 2 K with a maximum accelerating gradient of 25 MV/m, and the testing of a string of cavities integrated in a machine-type cryomodule. The cavity together with its helium tank had to be carefully designed in coherence with the innovative design of the cryomodule. New fabrication methods have also been explored. Five such niobium cavities and two copper cavities are in fabrication. The key design aspects are discussed, the results of the alternative fabrication methods presented and the stat...

  5. Long Wave Infrared Cavity Enhanced Sensors

    Energy Technology Data Exchange (ETDEWEB)

    Taubman, Matthew S.; Scott, David C.; Cannon, Bret D.; Myers, Tanya L.; Bonebrake, Christopher A.; Aker, Pam M.; Wojcik, Michael D.; Munley, John T.; Nguyen, Vinh T.; Schultz, John F.

    2004-10-01

    The principal goal of Pacific Northwest National Laboratory's (PNNL's) long wave infrared (LWIR) cavity enhanced sensor (CES) project is to explore ultra-sensitive spectroscopic techniques and apply them to the development of LWIR chemical sensors needed for detecting weapons proliferation. This includes detecting not only the weapons of mass destruction (WMDs) themselves, but also signatures of their production and/or detonation. The LWIR CES project is concerned exclusively with developing point sensors; other portions of PNNL's IR Sensors program address stand off detection. PNNL's LWIR CES research is distinguished from that done by others by the use quantum cascade lasers (QCLs) as the light source. QCLs are novel devices, and a significant fraction of our research has been devoted to developing the procedures and hardware required to implement them most effectively for chemical sensing. This report details the progress we have made on our LWIR CES sensor development. During FY02, PNNL investigated three LWIR CES implementations beginning with the easiest to implement, direct cavity-enhanced detection (simple CES), including a technique of intermediate difficulty, cavity-dithered phase-sensitive detection (FM recovery CES) through to the most complex technique, that of resonant sideband cavity-enhanced detection also known as noise-immune cavity-enhanced optical heterodyne molecular spectroscopy, or NICE-OHMS.

  6. Clinical outcome of high-dose-rate interstitial brachytherapy in patients with oral cavity cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sung Uk; Cho, Kwan Ho; Moon, Sung Ho; Choi, Sung Weon; Park, Joo Yong; Yun, Tak; Lee, Sang Hyun; Lim, Young Kyung; Jeong, Chi Young [National Cancer Center, Goyang (Korea, Republic of)

    2014-12-15

    To evaluate the clinical outcome of high-dose-rate (HDR) interstitial brachytherapy (IBT) in patients with oral cavity cancer. Sixteen patients with oral cavity cancer treated with HDR remote-control afterloading brachytherapy using 192Ir between 2001 and 2013 were analyzed retrospectively. Brachytherapy was administered in 11 patients as the primary treatment and in five patients as salvage treatment for recurrence after the initial surgery. In 12 patients, external beam radiotherapy (50-55 Gy/25 fractions) was combined with IBT of 21 Gy/7 fractions. In addition, IBT was administered as the sole treatment in three patients with a total dose of 50 Gy/10 fractions and as postoperative adjuvant treatment in one patient with a total of 35 Gy/7 fractions. The 5-year overall survival of the entire group was 70%. The actuarial local control rate after 3 years was 84%. All five recurrent cases after initial surgery were successfully salvaged using IBT +/- external beam radiotherapy. Two patients developed local recurrence at 3 and 5 months, respectively, after IBT. The acute complications were acceptable (< or =grade 2). Three patients developed major late complications, such as radio-osteonecrosis, in which one patient was treated by conservative therapy and two required surgical intervention. HDR IBT for oral cavity cancer was effective and acceptable in diverse clinical settings, such as in the cases of primary or salvage treatment.

  7. Effect of orally administered probenecid on the pharmacokinetics of cefoxitin.

    OpenAIRE

    Vlasses, P H; Holbrook, A M; Schrogie, J J; Rogers, J D; Ferguson, R K; Abrams, W B

    1980-01-01

    To characterize the effect of orally administered probenecid on the pharmacokinetics of cefoxitin in healthy male volunteers, we administered to one group of six subjects 2 g of cefoxitin by intravenous (i.v.) bolus either alone, with 1 g of probenecid concomitantly, or when 1 g of probenecid was administered 1 h previously by using a crossover design. Likewise, we administered to a second group of six subjects 2 g of cefoxitin intramuscularly (i.m.) together with 1 and 2 g of probenecid. Pro...

  8. Scheme for the implementation of a universal quantum cloning machine via cavity-assisted atomic collisions in cavity QED

    International Nuclear Information System (INIS)

    Zou Xubo; Pahlke, K.; Mathis, W.

    2003-01-01

    We propose a scheme to implement the 1→2 universal quantum cloning machine of Buzek and Hillery [Phys. Rev. A 54, 1844 (1996)] in the context of cavity QED. The scheme requires cavity-assisted collision processes between atoms, which cross through nonresonant cavity fields in the vacuum states. The cavity fields are only virtually excited to face the decoherence problem. That's why the requirements on the cavity quality factor can be loosened

  9. TM01 mode accelerating cavity optimization

    International Nuclear Information System (INIS)

    Manca, J.J.; Knapp, E.A.

    1978-08-01

    The cost of an accelerator depends greatly upon the effective use of rf power for particle acceleration. Before completing an accelerator design, an optimization of the accelerating cells relative to the effective shunt impedance should be made to measure the structure's efficiency in providing a high and effective acceleration of particles for a given rf power. Optimization of the accelerating cell resonant at f/sub r/ = 1350 MHz (TM 01 mode) relative to the maximum effective shunt impedance ZT 2 was performed at the Los Alamos Scientific Laboratory using the computer program SUPERFISH. The study was parametric; one parameter was changed while the others were held constant. Frequency adjustments were made by changing the cavity radius. Results presented in this report can be used to design similar cavities at different resonant frequencies or to design a more complicated cavity (TM 02 mode) for the disk and washer structure

  10. Single Atoms in Nearly Concentric Cavity

    Science.gov (United States)

    Utama, Adrian Nugraha; Nguyen, Chi Huan; Lewty, Nick; Kurtsiefer, Christian; Quantum Optics Group Team

    2017-04-01

    Strong interaction between photons and neutral single atoms are usually observed in cavity quantum electrodynamics (CQED) systems with high finesse mirrors and small physical volume. We demonstrate another approach that employs a near concentric cavity with relatively low finesse mirrors ( 100) and large physical separation between mirrors ( 10 mm). The transmission spectrum of our CQED system with trapped single atoms is observed to exhibit two resolved normal mode peaks, in which the single atom cooperativity is estimated to be around 0.4. The cooperativity of the system can be improved further by increasing the finesse of the mirrors or moving the cavity closer to the concentric point. The successful realization of concentric CQED systems will open opportunities for scaling up with applications in quantum computing. This work is supported by the National Research Foundation and Ministry of Education, Singapore.

  11. PEP-II RF cavity revisited

    International Nuclear Information System (INIS)

    Rimmer, R.A.; Koehler, G.; Li, D.; Hartman, N.; Folwell, N.; Hodgson, J.; Ko, K.; McCandless, B.

    1999-01-01

    This report describes the results of numerical simulations of the PEP-II RF cavity performed after the completion of the construction phase of the project and comparisons are made to previous calculations and measured results. These analyses were performed to evaluate new calculation techniques for the HOM distribution and RF surface heating that were not available at the time of the original design. These include the use of a high frequency electromagnetic element in ANSYS and the new Omega 3P code to study wall losses, and the development of broadband time domain simulation methods in MAFIA for the HOM loading. The computed HOM spectrum is compared with cavity measurements and observed beam-induced signals. The cavity fabrication method is reviewed, with the benefit of hindsight, and simplifications are discussed

  12. Enhanced Method for Cavity Impedance Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Frank Marhauser, Robert Rimmer, Kai Tian, Haipeng Wang

    2009-05-01

    With the proposal of medium to high average current accelerator facilities the demand for cavities with extremely low Higher Order Mode (HOM) impedances is increasing. Modern numerical tools are still under development to more thoroughly predict impedances that need to take into account complex absorbing boundaries and lossy materials. With the usually large problem size it is preferable to utilize massive parallel computing when applicable and available. Apart from such computational issues, we have developed methods using available computer resources to enhance the information that can be extracted from a cavities? wakefield computed in time domain. In particular this is helpful for a careful assessment of the extracted RF power and the mitigation of potential beam break-up or emittance diluting effects, a figure of merit for the cavity performance. The method is described as well as an example of its implementation.

  13. Coupled Photonic Crystal Cavity Array Laser

    DEFF Research Database (Denmark)

    Schubert, Martin

    This thesis describes the design, fabrication and characterization of photonic crystal slab lasers. The main focus is on coupled photonic crystal cavity lasers which are examined in great detail. The cavity type which is mainly explored consists of a defect formed by a single missing hole...... in the quadratic lattice. Processing techniques are developed and optimized in order fabricate photonic crystals membranes in gallium arsenide with quantum dots as gain medium and in indium gallium arsenide phosphide with quantum wells as gain medium. Several key issues in process to ensure good quality...... are identified such as the size and material for the carrier wafer in the III-V etch and the importance of removing all remains of the e-beam lithography mask after the etch of the hard mask. Detailed simulations are shown for a simple system with two coupled cavities in different coupling directions...

  14. Circuit QED with 3D cavities

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Edwar; Eder, Peter; Fischer, Michael; Goetz, Jan; Deppe, Frank; Gross, Rudolf [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, 85748 Garching (Germany); Physik-Department, TU Muenchen, 85748 Garching (Germany); Nanosystems Initiative Munich (NIM), 80799 Muenchen (Germany); Haeberlein, Max; Wulschner, Karl Friedrich [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, 85748 Garching (Germany); Physik-Department, TU Muenchen, 85748 Garching (Germany); Fedorov, Kirill; Marx, Achim [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, 85748 Garching (Germany)

    2016-07-01

    In typical circuit QED systems, on-chip superconducting qubits are coupled to integrated coplanar microwave resonators. Due to the planar geometry, the resonators are often a limiting factor regarding the total coherence of the system. Alternatively, similar hybrid systems can be realized using 3D microwave cavities. Here, we present studies on transmon qubits capacitively coupled to 3D cavities. The internal quality factors of our 3D cavities, machined out of high purity aluminum, are above 1.4 .10{sup 6} at the single photon level and a temperature of 50 mK. For characterization of the sample, we perform dispersive shift measurements up to the third energy level of the qubit. We show simulations and data describing the effect of the transmon geometry on it's capacitive properties. In addition, we present progress towards an integrated quantum memory application.

  15. Minimum wakefield achievable by waveguide damped cavity

    International Nuclear Information System (INIS)

    Lin, X.E.; Kroll, N.M.

    1995-01-01

    The authors use an equivalent circuit to model a waveguide damped cavity. Both exponentially damped and persistent (decay t -3/2 ) components of the wakefield are derived from this model. The result shows that for a cavity with resonant frequency a fixed interval above waveguide cutoff, the persistent wakefield amplitude is inversely proportional to the external Q value of the damped mode. The competition of the two terms results in an optimal Q value, which gives a minimum wakefield as a function of the distance behind the source particle. The minimum wakefield increases when the resonant frequency approaches the waveguide cutoff. The results agree very well with computer simulation on a real cavity-waveguide system

  16. Cavity lining after excavating caries lesions

    DEFF Research Database (Denmark)

    Schwendicke, Falk; Göstemeyer, Gerd; Gluud, Christian

    2015-01-01

    OBJECTIVES: After removal of dentin caries lesions, cavity lining has been advocated. Non-clinical data support this approach, but clinical data are sparse and ambiguous. We aimed at evaluating the benefits and harms of cavity lining using meta-analysis and Trial Sequential Analysis. DATA: We...... included randomized clinical trials comparing restorations without versus with cavity lining for treating primary caries lesions. Only trials reporting failure (defined as need to re-retreat) after ≥1 year follow-up were included. Trial selection, data extraction, and risk of bias assessment were conducted....... STUDY SELECTION: From 128 studies, three randomized trials (89/130 patients or teeth), all treating primary teeth, were included. The trials had high risk of bias. All trials compared no lining versus calcium hydroxide lining after selective caries removal followed by adhesive restoration. Follow...

  17. Prominence Mass Supply and the Cavity

    Science.gov (United States)

    Schmit, Donald J.; Gibson, S.; Luna, M.; Karpen, J.; Innes, D.

    2013-01-01

    A prevalent but untested paradigm is often used to describe the prominence-cavity system; the cavity is under-dense because it it evacuated by supplying mass to the condensed prominence. The thermal non-equilibrium (TNE) model of prominence formation offers a theoretical framework to predict the thermodynamic evolutin of the prominence and the surrounding corona. We examine the evidence for a prominence-cavity connection by comparing the TNE model and diagnostics of dynamic extreme ultraviolet (EUV) emission surrounding the prominence, specifically prominence horns. Horns are correlated extensions of prminence plasma and coronal plasma which appear to connect the prominence and cavity. The TNE model predicts that large-scale brightenings will occur in the Solar Dynamics Observatory Atmospheric Imaging Assembly 171 A badpass near he prominence that are associated with the cooling phase of condensation formation. In our simulations, variations in the magnitude of footpoint heating lead to variations in the duration, spatial scale, and temporal offset between emission enhancements in the other EUV bandpasses. While these predictions match well a subset of the horn observations, the range of variations in the observed structures is not captured by the model. We discuss the implications of one-dimensional loop simulations for the three-dimensional time-averaged equilibrium in the prominence and the cavity. Evidence suggests that horns are likely caused by condensing prominence plasma, but the larger question of whether this process produces a density-depleted cavity requires a more tightly constrained model of heating and better knowledge of the associated magnetic structure.

  18. Seismic wave interaction with underground cavities

    Science.gov (United States)

    Schneider, Felix M.; Esterhazy, Sofi; Perugia, Ilaria; Bokelmann, Götz

    2016-04-01

    Realization of the future Comprehensive Nuclear Test Ban Treaty (CTBT) will require ensuring its compliance, making the CTBT a prime example of forensic seismology. Following indications of a nuclear explosion obtained on the basis of the (IMS) monitoring network further evidence needs to be sought at the location of the suspicious event. For such an On-Site Inspection (OSI) at a possible nuclear test site the treaty lists several techniques that can be carried out by the inspection team, including aftershock monitoring and the conduction of active seismic surveys. While those techniques are already well established, a third group of methods labeled as "resonance seismometry" is less well defined and needs further elaboration. A prime structural target that is expected to be present as a remnant of an underground nuclear explosion is a cavity at the location and depth the bomb was fired. Originally "resonance seismometry" referred to resonant seismic emission of the cavity within the medium that could be stimulated by an incident seismic wave of the right frequency and observed as peaks in the spectrum of seismic stations in the vicinity of the cavity. However, it is not yet clear which are the conditions for which resonant emissions of the cavity could be observed. In order to define distance-, frequency- and amplitude ranges at which resonant emissions could be observed we study the interaction of seismic waves with underground cavities. As a generic model for possible resonances we use a spherical acoustic cavity in an elastic full-space. To solve the forward problem for the full elastic wave field around acoustic spherical inclusions, we implemented an analytical solution (Korneev, 1993). This yields the possibility of generating scattering cross-sections, amplitude spectrums and synthetic seismograms for plane incident waves. Here, we focus on the questions whether or not we can expect resonant responses in the wave field scattered from the cavity. We show

  19. Plasma processing of superconducting radio frequency cavities

    Science.gov (United States)

    Upadhyay, Janardan

    The development of plasma processing technology of superconducting radio frequency (SRF) cavities not only provides a chemical free and less expensive processing method, but also opens up the possibility for controlled modification of the inner surfaces of the cavity for better superconducting properties. The research was focused on the transition of plasma etching from two dimensional flat surfaces to inner surfaces of three dimensional (3D) structures. The results could be applicable to a variety of inner surfaces of 3D structures other than SRF cavities. Understanding the Ar/Cl2 plasma etching mechanism is crucial for achieving the desired modification of Nb SRF cavities. In the process of developing plasma etching technology, an apparatus was built and a method was developed to plasma etch a single cell Pill Box cavity. The plasma characterization was done with the help of optical emission spectroscopy. The Nb etch rate at various points of this cavity was measured before processing the SRF cavity. Cylindrical ring-type samples of Nb placed on the inner surface of the outer wall were used to measure the dependence of the process parameters on plasma etching. The measured etch rate dependence on the pressure, rf power, dc bias, temperature, Cl2 concentration and diameter of the inner electrode was determined. The etch rate mechanism was studied by varying the temperature of the outer wall, the dc bias on the inner electrode and gas conditions. In a coaxial plasma reactor, uniform plasma etching along the cylindrical structure is a challenging task due to depletion of the active radicals along the gas flow direction. The dependence of etch rate uniformity along the cylindrical axis was determined as a function of process parameters. The formation of dc self-biases due to surface area asymmetry in this type of plasma and its variation on the pressure, rf power and gas composition was measured. Enhancing the surface area of the inner electrode to reduce the

  20. Coherent acoustic excitation of cavity polaritons

    DEFF Research Database (Denmark)

    Poel, Mike van der; de Lima, M. M.; Hey, R.

    and highly nonlinear optical response.Our sample consists of epitaxially grown GaAs/AlGaAs QWs located at the anti-node ofa high Q lambda cavity, which is resonant with the QW excitonic transition3. The SAWfield, which is excited by an interdigital transducer on the piezoelectric GaAs samplesurface......, modulates the refractive index and displaces the material causing a harmonicmodulation of the PBG structure1. This periodic modulation of the cavity-exciton systemleads to in-plane mini-Brillouin zone (MBZ) formation. The very high vacuum-Rabisplitting of our sample enables us to clearly resolve...

  1. Electrically Pumped Vertical-Cavity Amplifiers

    DEFF Research Database (Denmark)

    Greibe, Tine

    2007-01-01

    . Detailed descriptions of the structure designs, clean room processing procedures and characterisations of the designs are presented in this thesis. Furthermore, comprehensive simulations of carrier distributions in the quantum well sections and the gain saturation of the different designs are performed...... of one of our bottom-emitting designs are good. It has an optical output power that is promising for use in an external-cavity mode-locked laser. The growth of the structure however went wrong and the structure has no net gain, which spoiled our chances to investigate it further in an external cavity...

  2. Parasitic Cavities Losses in SPEAR-2

    Energy Technology Data Exchange (ETDEWEB)

    Sands, M.; /SLAC

    2016-12-19

    In PEP the large number of particles in a bunch, together with the small bunch length, may cause grievous energy loss from the beam to parasitic modes in the accelerating cavities. I have recently tried to estimate the parasitic cavity in PEP, based on a paper of Keil and I have obtained the result that the loss to parasitic modes will be about 10 MeV per particle per revolution for a bunch length of about 10 cm. In this note, I bring together some of the considerations that might bear on an experimental investigation of the loss using SPEAR-2.

  3. Short-cavity squeezing in barium

    Science.gov (United States)

    Hope, D. M.; Bachor, H-A.; Manson, P. J.; Mcclelland, D. E.

    1992-01-01

    Broadband phase sensitive noise and squeezing were experimentally observed in a system of barium atoms interacting with a single mode of a short optical cavity. Squeezing of 13 +/- 3 percent was observed. A maximum possible squeezing of 45 +/- 8 percent could be inferred for out experimental conditions, after correction for measured loss factors. Noise reductions below the quantum limit were found over a range of detection frequencies 60-170 MHz and were best for high cavity transmission and large optical depths. The amount of squeezing observed is consistent with theoretical predictions from a full quantum statistical model of the system.

  4. Numerical simulation of coupler cavities for linacs

    Energy Technology Data Exchange (ETDEWEB)

    Ng, C.K.; Derutyer, H.; Ko, K.

    1993-04-01

    We present numerical procedures involved in the evaluation of the performance of coupler cavities for linacs. The MAFIA code is used to simulate an X-Band accelerator section in the time domain. The input/output coupler cavities for the structure arc of the symmetrical double-input design. We calculate the transmission properties of the coupler and compare the results with measurements. We compare the performance of the symmetrical double-input design with that of the conventional single-input type by evaluating the field amplitude and phase asymmetries. We also evaluate the peak field gradient in the computer.

  5. Coupled Geomechanical Simulations of UCG Cavity Evolution

    Energy Technology Data Exchange (ETDEWEB)

    Morris, J P; Buscheck, T A; Hao, Y

    2009-07-13

    This paper presents recent work from an ongoing project to develop predictive tools for cavity/combustion-zone growth and to gain quantitative understanding of the processes and conditions (both natural and engineered) affecting underground coal gasification (UCG). In this paper we will focus upon the development of coupled geomechanical capabilities for simulating the evolution of the UCG cavity using discrete element methodologies. The Discrete Element Method (DEM) has unique advantages for facilitating the prediction of the mechanical response of fractured rock masses, such as cleated coal seams. In contrast with continuum approaches, the interfaces within the coal can be explicitly included and combinations of both elastic and plastic anisotropic response are simulated directly. Additionally, the DEM facilitates estimation of changes in hydraulic properties by providing estimates of changes in cleat aperture. Simulation of cavity evolution involves a range of coupled processes and the mechanical response of the host coal and adjoining rockmass plays a role in every stage of UCG operations. For example, cavity collapse during the burn has significant effect upon the rate of the burn itself. In the vicinity of the cavity, collapse and fracturing may result in enhanced hydraulic conductivity of the rock matrix in the coal and caprock above the burn chamber. Even far from the cavity, stresses due to subsidence may be sufficient to induce new fractures linking previously isolated aquifers. These mechanical processes are key in understanding the risk of unacceptable subsidence and the potential for groundwater contamination. These mechanical processes are inherently non-linear, involving significant inelastic response, especially in the region closest to the cavity. In addition, the response of the rock mass involves both continuum and discrete mechanical behavior. We have recently coupled the LDEC (Livermore Distinct Element Code) and NUFT (Non

  6. Accelerating RF cavity of the Booster

    CERN Multimedia

    CERN PhotoLab

    1981-01-01

    Each of the 4 PS Booster rings has a single accelerating cavity. It consists of 2 quarter-wave ferrite-loaded resonators. There are 2 figure-of-eight loops on the ferrite loads for tuning the frequency throughout the acceleration cycle, from 3 to 8 MHz (from 50 MeV at injection to the original Booster energy of 800 MeV, 2 GeV today). The cavities have a flat design, to fit the ring-to-ring distance of 36 cm. The tube for forced-air cooling is visible in the left front. See also 8301084.

  7. Accelerating RF cavity of the Booster

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    Each of the 4 PS Booster rings has a single accelerating cavity.It consists of 2 quarter-wave ferrite-loaded resonators. 2 figure-of-eight loops tune the frequency throughout the accelerating cycle, from 3 to 8 MHz (from 50 MeV at injection to the original Booster energy of 800 MeV, 2 GeV today). The cavities have a flat design, to fit the ring-to-ring distance of 36 cm, and are forced-air cooled. The 2 round objects in the front-compartments are the final-stage power-tetrodes. See also 8111095.

  8. Short-cavity squeezing in barium

    International Nuclear Information System (INIS)

    Hope, D.M.; Bachor, H-A.; Manson, P.J.; Mcclelland, D.E.

    1992-01-01

    Broadband phase sensitive noise and squeezing were experimentally observed in a system of barium atoms interacting with a single mode of a short optical cavity. Squeezing of 13 +/- 3 percent was observed. A maximum possible squeezing of 45 +/- 8 percent could be inferred for out experimental conditions, after correction for measured loss factors. Noise reductions below the quantum limit were found over a range of detection frequencies 60-170 MHz and were best for high cavity transmission and large optical depths. The amount of squeezing observed is consistent with theoretical predictions from a full quantum statistical model of the system

  9. Progress in diagnostic techniques for sc cavities

    International Nuclear Information System (INIS)

    Reece, C.E.

    1988-01-01

    While routinely achieved performance characteristics of superconducting cavities have now reached a level which makes them useful in large scale applications, achieving this level has come only through the knowledge gained by systematic studies of performance limiting phenomena. Despite the very real progress that has been made, the routine performance of superconducting cavities still falls far short of both the theoretical expectations and the performance of a few exception examples. It is the task of systematically applied diagnostic techniques to reveal additional information concerning the response of superconducting surfaces to applied RF fields. Here recent developments in diagnostic techniques are discussed. 18 references, 12 figures

  10. Advanced acoustic cavity technology. [for hydrogen oxygen rocket engines

    Science.gov (United States)

    Hines, W. S.; Oberg, C. L.; Kusak, L.

    1974-01-01

    A series of rocket motor firings was performed in a modified linear aerospike thrust chamber with the H2/O2 propellant combination to allow determination of the physical properties of the combustion gases in acoustic cavities located in the chamber side walls. A preliminary analytical study was first conducted to define theoretically both the appropriate cavity dimensions and the combustion gas flow field adjacent to the cavity openings. During the subsequent motor firings, cavity gas temperature profiles were measured and gas samples were withdrawn from the bottom of the cavities for compositional analysis by measurement of pressure/temperature variation and gas chromatography. Data were obtained with both radially and axially oriented cavities and with and without hydrogen bleed flow through the cavities. A simplified procedure was developed for predicting gas cavity and acoustic velocity for use in acoustic cavity design analyses.

  11. Methods of administering oral formulations and child acceptability

    NARCIS (Netherlands)

    van Riet-Nales, Diana A; Ferreira, José A; Schobben, Alfred F A M; de Neef, Barbara J; Egberts, Toine C G; Rademaker, Carin M A

    2015-01-01

    INTRODUCTION: Children may be unable or unwilling to swallow medicines. In order to avoid or accommodate any such problems, parents may decide to administer medicines other than intended. The aim of this study was to investigate how parents administered four oral placebo formulations to infants and

  12. Methods of administering oral formulations and child acceptability

    NARCIS (Netherlands)

    Van Riet-Nales, Diana A.; Ferreira, José A.; Schobben, Alfred F A M; De Neef, Barbara J.; Egberts, Toine C G; Rademaker, Carin M A

    2015-01-01

    Abstract Introduction Children may be unable or unwilling to swallow medicines. In order to avoid or accommodate any such problems, parents may decide to administer medicines other than intended. The aim of this study was to investigate how parents administered four oral placebo formulations to

  13. 39 CFR 222.1 - Authority to administer postal affairs.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Authority to administer postal affairs. 222.1 Section 222.1 Postal Service UNITED STATES POSTAL SERVICE ORGANIZATION AND ADMINISTRATION DELEGATIONS OF AUTHORITY § 222.1 Authority to administer postal affairs. (a) The Postmaster General. The postmaster general...

  14. 40 CFR 147.2801 - EPA-administered program.

    Science.gov (United States)

    2010-07-01

    ... Section 147.2801 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) STATE, TRIBAL, AND EPA-ADMINISTERED UNDERGROUND INJECTION CONTROL PROGRAMS Commonwealth of the... lands in the Commonwealth of the Northern Mariana Islands is administered by EPA. This program consists...

  15. 40 CFR 147.2851 - EPA-administered program.

    Science.gov (United States)

    2010-07-01

    ... Section 147.2851 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) STATE, TRIBAL, AND EPA-ADMINISTERED UNDERGROUND INJECTION CONTROL PROGRAMS Trust Territory of the... the Pacific Islands, including all Indian lands, is administered by EPA. This program consists of the...

  16. 40 CFR 147.2850 - State-administered program. [Reserved

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false State-administered program. 147.2850 Section 147.2850 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) STATE, TRIBAL, AND EPA-ADMINISTERED UNDERGROUND INJECTION CONTROL PROGRAMS Trust Territory of the...

  17. A Computer-Administered Examination in Professional Ethics.

    Science.gov (United States)

    White, Michael J.

    1988-01-01

    Presents rationale and procedure for a computer-administered examination in professional ethics. Discusses advantages and implications of computer-administered testing in professional ethics, noting benefits for instructors and students of professional ethics in counseling and counseling psychology. (Author/NB)

  18. Influence from cavity decay on geometric quantum computation in the large-detuning cavity QED model

    International Nuclear Information System (INIS)

    Chen Changyong; Zhang Xiaolong; Deng Zhijiao; Gao Kelin; Feng Mang

    2006-01-01

    We introduce a general displacement operator to investigate the unconventional geometric quantum computation with dissipation under the model of many identical three-level atoms in a cavity, driven by a classical field. Our concrete calculation is made for the case of two atoms, based on a previous scheme [S.-B. Zheng, Phys. Rev. A 70, 052320 (2004)] for the large-detuning interaction of the atoms with the cavity mode. The analytical results we present will be helpful for experimental realization of geometric quantum computation in real cavities

  19. A study on utility of magnetic resonance imaging for female pelvic cavity using enteral MRI contrast media

    International Nuclear Information System (INIS)

    Kim, Ham Gyum

    1997-01-01

    For radiological test in soft tissue or neighboring part with same signal intensity, proper test method and equipment shall be selected as needed. In case of female pelvic cavity, ultrasonography or computed tomography alternatively used, but MRI can be more usefully applied to design treatment method or operation plan by improving the diagnostic accuracy and careful observation of lesion characteristics. Magnetic Resonance Imaging using recently developed Enteral MRI contrast media can acquire more diagnostic information than using only intravenous contrast media. Thus this study attempted to examine the utility of anatomic structure and diagnostic acquisition by imaging the female pelvic cavity using Enteral MRI contrast media. As a result of analyzing magnetic resonance imaging after administering Enteral MRI contrast media to pelvic cavity suspect patients, more diagnostic information media could be acquired than only using intravenous contrast. Especially, in the diagnosis of lesion position, shape, distinction from neighboring tissues it is thought that external Enteral MRI contrast media should be used

  20. Injector Cavities Fabrication, Vertical Test Performance and Primary Cryomodule Design

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Haipeng [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Cheng, Guangfeng [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Clemens, William [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Davis, G [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Macha, Kurt [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Overton, Roland [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Spell, D. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2015-09-01

    After the electromagnetic design and the mechanical design of a β=0.6, 2-cell elliptical SRF cavity, the cavity has been fabricated. Then both 2-cell and 7-cell cavities have been bench tuned to the target values of frequency, coupling external Q and field flatness. After buffer chemistry polishing (BCP) and high pressure rinses (HPR), Vertical 2K cavity test results have been satisfied the specifications and ready for the string assembly. We will report the cavity performance including Lorenz Force Detuning (LFD) and Higher Order Modes (HOM) damping data. Its integration with cavity tuners to the cryomodule design will be reported.

  1. Analysis of mechanical fabrication experience with CEBAF's production SRF cavities

    International Nuclear Information System (INIS)

    Mammosser, J.; Kneisel, P.; Benesch, J.

    1993-06-01

    CEBAF has received a total of 360 five-cell niobium cavities, the largest group of industrially fabricated superconducting cavities so far. An extensive data base exists on the fabrication, surface treatment, assembly and cavity performance parameters. Analysis of the mechanical features of the cavities includes the following: the spread in fabrication tolerances of the cells derived from field profiles of the ''as fabricated'' cavities and the ''as fabricated'' external Q-values of the fundamental power coupler compared to dimensional deviations. A comparison is made of the pressure sensitivity of cavities made of materials from different manufacturers between 760 torr (4.2 K) and 23 torr (2 K)

  2. Atmospheric signals produced by cavity rebound

    International Nuclear Information System (INIS)

    Jones, E.M.; App, F.N.; Whitaker, R.W.

    1993-01-01

    An analysis of the atmospheric acoustic signals produced by a class of low-yield tests conducted just below the base of the alluvial cover in Yucca Flat of the Nevada Test Site (NTS), has revealed a clear manifestation of an elastic, cavity rebound signal. We use modeling as the basis for understanding the observed phenomena

  3. AGN Heating Through Cavities and Shocks

    NARCIS (Netherlands)

    Nulsen, P.E.J.; Jones, C.; Forman, W.R.; David, L.P.; McNamara, B.R.; Rafferty, D.A.; Bîrzan, L.; Wise, M.

    2007-01-01

    Three comments are made on AGN heating of cooling flows. A simple physical argument is used to show that the enthalpy of a buoyant radio lobe is converted to heat in its wake. Thus, a significant part of ``cavity'' enthalpy is likely to end up as heat. Second, the properties of the repeated weak

  4. Lambda shifted photonic crystal cavity laser

    DEFF Research Database (Denmark)

    Schubert, Martin; Skovgård, Troels Suhr; Ek, Sara

    2010-01-01

    We propose and demonstrate an alternative type of photonic crystal laser design that shifts all the holes in the lattice by a fixed fraction of the targeted emission wavelength. The structures are realized in InGaAsP =1.15 with InGaAsP quantum wells =1.52 as gain material. Cavities with shifts of...

  5. The Design of the Orthogonal Box Cavity

    Energy Technology Data Exchange (ETDEWEB)

    Moretti, Alfred; /Fermilab

    2010-09-15

    The muon collider and/or the neutrino factory require large accelerating electric field gradients immersed in large (3 to 6 T) solenoidal magnetic fields for ionization cooling of muon beams. Our original vacuum breakdown study demonstrated a loss of achievable peak accelerating gradient in solenoidal magnetic fields by a factor 2 or greater. The Muon Collaboration has developed a theory of a method to suppress high electric field breakdown in vacuum cavities needed for a Muon collider or neutrino factory. It has been shown in our studies and by others that high gradient electric field emitted electrons (dark current) are the primary cause of breakdown. A DC magnetic field orthogonal to the RF electric accelerating field prevents dark current high field emitted electrons from traveling across the accelerating gap and then will prevent breakdown. We have decided to test this theory by building a special cavity in the shape of vacuum box. Figure 1 is a simplified view of the cavity design. The design is based on an 805 MHz WR975 waveguide cavity resonating in the TE{sub 101} mode. For the TE{sub 101} mode the resonant frequency f{sub 0} is given by the relationship f{sub 0} = c[(I/a){sup 2} + (m/b){sup 2} + (n/d){sup 2}]{sup 0.5}/2 where a and d are the lengths of the base sides and b is the height of the box in MKS units and c is the velocity of light.

  6. Wall compliance and violin cavity modes.

    Science.gov (United States)

    Bissinger, George

    2003-03-01

    Violin corpus wall compliance, which has a substantial effect on cavity mode frequencies, was added to Shaw's two-degree-of-freedom (2DOF) network model for A0 ("main air") and A1 (lowest length mode included in "main wood") cavity modes. The 2DOF model predicts a V(-0.25) volume dependence for A0 for rigid violin-shaped cavities, to which a semiempirical compliance correction term, V(-x(c)) (optimization parameter x(c)) consistent with cavity acoustical compliance and violin-based scaling was added. Optimizing x(c) over A0 and A1 frequencies measured for a Hutchins-Schelleng violin octet yielded x(c) approximately 0.08. This markedly improved A0 and A1 frequency predictions to within approximately +/- 10% of experiment over a range of about 4.5:1 in length, 10:1 in f-hole area, 3:1 in top plate thickness, and 128:1 in volume. Compliance is a plausible explanation for A1 falling close to the "main wood" resonance, not increasingly higher for the larger instruments, which were scaled successively shorter compared to the violin for ergonomic and practical reasons. Similarly incorporating compliance for A2 and A4 (lowest lower-/upper-bout modes, respectively) improves frequency predictions within +/-20% over the octet.

  7. Lasers with intra-cavity phase elements

    Science.gov (United States)

    Gulses, A. Alkan; Kurtz, Russell; Islas, Gabriel; Anisimov, Igor

    2018-02-01

    Conventional laser resonators yield multimodal output, especially at high powers and short cavity lengths. Since highorder modes exhibit large divergence, it is desirable to suppress them to improve laser quality. Traditionally, such modal discriminations can be achieved by simple apertures that provide absorptive loss for large diameter modes, while allowing the lower orders, such as the fundamental Gaussian, to pass through. However, modal discrimination may not be sufficient for short-cavity lasers, resulting in multimodal operation as well as power loss and overheating in the absorptive part of the aperture. In research to improve laser mode control with minimal energy loss, systematic experiments have been executed using phase-only elements. These were composed of an intra-cavity step function and a diffractive out-coupler made of a computer-generated hologram. The platform was a 15-cm long solid-state laser that employs a neodymium-doped yttrium orthovanadate crystal rod, producing 1064 nm multimodal laser output. The intra-cavity phase elements (PEs) were shown to be highly effective in obtaining beams with reduced M-squared values and increased output powers, yielding improved values of radiance. The utilization of more sophisticated diffractive elements is promising for more difficult laser systems.

  8. A variational computation for coved cavity structure

    International Nuclear Information System (INIS)

    Pan Weimin; Zhou Wenzhen

    1992-01-01

    In order to improve the beam quality and reduce the beam breakup and wake effects caused by the high beam current in electron linac, the coved cavity with big beam hole is used in the world. A variational method is used, and the results are similar to that of Boeing Company

  9. Congenital malformation of inner ear, single cavity

    International Nuclear Information System (INIS)

    Torres Pazmino, Julio Cesar; Marrugo Pardo, Gilberto Eduardo

    2010-01-01

    Congenital malformations of the inner ear are rare conditions, but their detection requires high diagnostic accuracy. In this report we describe the case of a patient with single or common cavity, discuss the corresponding radiological images, describe the treatment of this patient with a cochlear implant, and review the classification and differential diagnosis of the other anomalies of the inner ear.

  10. Quantization of Electromagnetic Fields in Cavities

    Science.gov (United States)

    Kakazu, Kiyotaka; Oshiro, Kazunori

    1996-01-01

    A quantization procedure for the electromagnetic field in a rectangular cavity with perfect conductor walls is presented, where a decomposition formula of the field plays an essential role. All vector mode functions are obtained by using the decomposition. After expanding the field in terms of the vector mode functions, we get the quantized electromagnetic Hamiltonian.

  11. Nonlinear Analysis of Cavities in Rock Salt

    DEFF Research Database (Denmark)

    Ottosen, N. S.; Krenk, Steen

    1979-01-01

    The paper covers some material and computational aspects of the rock mechanics of leached cavities in salt. A material model is presented in which the instantaneous stiffness of the salt is obtained by interpolation between the unloaded state and a relevant failure state. The model enables predic...

  12. Pressurized rf cavities in ionizing beams

    Directory of Open Access Journals (Sweden)

    B. Freemire

    2016-06-01

    Full Text Available A muon collider or Higgs factory requires significant reduction of the six dimensional emittance of the beam prior to acceleration. One method to accomplish this involves building a cooling channel using high pressure gas filled radio frequency cavities. The performance of such a cavity when subjected to an intense particle beam must be investigated before this technology can be validated. To this end, a high pressure gas filled radio frequency (rf test cell was built and placed in a 400 MeV beam line from the Fermilab linac to study the plasma evolution and its effect on the cavity. Hydrogen, deuterium, helium and nitrogen gases were studied. Additionally, sulfur hexafluoride and dry air were used as dopants to aid in the removal of plasma electrons. Measurements were made using a variety of beam intensities, gas pressures, dopant concentrations, and cavity rf electric fields, both with and without a 3 T external solenoidal magnetic field. Energy dissipation per electron-ion pair, electron-ion recombination rates, ion-ion recombination rates, and electron attachment times to SF_{6} and O_{2} were measured.

  13. Plasma Evolution within an Erupting Coronal Cavity

    Science.gov (United States)

    Long, David M.; Harra, Louise K.; Matthews, Sarah A.; Warren, Harry P.; Lee, Kyoung-Sun; Doschek, George A.; Hara, Hirohisa; Jenkins, Jack M.

    2018-03-01

    Coronal cavities have previously been observed to be associated with long-lived quiescent filaments and are thought to correspond to the associated magnetic flux rope. Although the standard flare model predicts a coronal cavity corresponding to the erupting flux rope, these have only been observed using broadband imaging data, restricting an analysis to the plane-of-sky. We present a unique set of spectroscopic observations of an active region filament seen erupting at the solar limb in the extreme ultraviolet. The cavity erupted and expanded rapidly, with the change in rise phase contemporaneous with an increase in nonthermal electron energy flux of the associated flare. Hot and cool filamentary material was observed to rise with the erupting flux rope, disappearing suddenly as the cavity appeared. Although strongly blueshifted plasma continued to be observed flowing from the apex of the erupting flux rope, this outflow soon ceased. These results indicate that the sudden injection of energy from the flare beneath forced the rapid eruption and expansion of the flux rope, driving strong plasma flows, which resulted in the eruption of an under-dense filamentary flux rope.

  14. All-optical tunable photonic crystal cavity

    DEFF Research Database (Denmark)

    Pu, Minhao; Liu, Liu; Ou, Haiyan

    2010-01-01

    We demonstrate an ultra-small photonic crystal cavity with two resonant modes. An all-optical tuning operation based on the free-carrier plasma effect is, for the first time, realized utilizing a continuous wave light source. The termo-optical effect is minimized by isoproponal infiltration...

  15. Direct Numerical Simulation of Driven Cavity Flows

    NARCIS (Netherlands)

    Verstappen, R.; Wissink, J.G.; Veldman, A.E.P.

    Direct numerical simulations of 2D driven cavity flows have been performed. The simulations exhibit that the flow converges to a periodically oscillating state at Re=11,000, and reveal that the dynamics is chaotic at Re=22,000. The dimension of the attractor and the Kolmogorov entropy have been

  16. Characterization and simulation of a pillbox cavity

    CERN Document Server

    Moran Guizan, Carla

    2017-01-01

    A cylindrical pillbox cavity is characterized and its principal parameters, such as the cut-off frequencies of the modes, the quality factor and R/Q figure, are calculated. Additionally, these measurements are compared with an analytical analysis and with a simulation with the software CST Studio to determine how precise they are.

  17. Shear Layer Dynamics in Resonating Cavity Flows

    National Research Council Canada - National Science Library

    Ukeiley, Lawrence

    2004-01-01

    .... The PIV data was also combined with the surface pressure measurements through the application of the Quadratic Stochastic Estimation procedure to provide time resolved snapshots of the flow field. Examination of these results indicate the strong pumping action of the cavity regardless of whether resonance existed and was used to visualize the large scale structures interacting with the aft wall.

  18. Natural convection inside an irregular porous cavity

    International Nuclear Information System (INIS)

    Beltran, Jorge I. LLagostera; Trevisan, Osvair Vidal

    1990-01-01

    Natural convection flow induced by heating from below in a irregular porous cavity is investigated numerically. The influence of the modified Rayleigh number and geometric ratios on heat transfer and fluid flow is studied. Global and local Nusselt for Rayleigh numbers covering the range 0 - 1600 and for several geometric ratios. The fluid flow and the temperature field are illustrated by contour maps. (author)

  19. Efficacy and Safety of Orally Administered Intravenous Midazolam Versus a Commercially Prepared Syrup

    Science.gov (United States)

    Salem, Katayoun; Khoshrang, Hossein; Kousha, Maryam; Hoseini, Mahboobeh; Ranjbar, Marzieh; Baniasadi, Shadi; Salamzadeh, Jamshid

    2015-01-01

    Background: Among different categories of sedative agents, benzodiazepines have been prescribed for more than three decades to patients of all ages. The effective and predictable sedative and amnestic effects of benzodiazepines support their use in pediatric patients. Midazolam is one of the most extensively used benzodiazepines in this age group. Oral form of drug is the best accepted route of administration in children. Objectives: The purpose of this study was to compare the efficacy and safety of a commercially midazolam syrup versus orally administered IV midazolam in uncooperative dental patients. Second objective was to determine whether differences concerning sedation success can be explained by child‘s behavioral problems and dental fear. Patients and Methods: Eighty eight uncooperative dental patients (Frankl Scales 1,2) aged 3 to 6 years, and ASA I participated in this double blind, parallel randomized, controlled clinical trial. Midazolam was administered in a dose of 0.5 mg/kg for children under the age 5 and 0.2 mg/kg in patients over 5 years of age. Physiologic parameters including heart rate, respiratory rate, oxygen saturation and blood pressure were recorded. Behavior assessment was conducted throughout the course of treatment using Houpt Sedation Rating Scale and at critical moments of treatment (injection and cavity preparation) by North Carolina Scale. Dental fear and behavioral problems were evaluated using Child Fear Schedule Survey-Dental Subscale (CFSS-DS), and Strength and Difficulties Questionnaire (SDQ). Independent t-test, Chi-Square, and Pearson correlation were used for statistical analysis. Results: Acceptable overall sedation ratings were observed in 90% and 86% of syrup and IV/Oral group respectively; Chi-Square P = 0.5. Other domains of Houpt Scale including: sleep, crying and movement were also not significantly different between groups. Physiological parameters remained in normal limits during study without significant

  20. Accoustic Localization of Breakdown in Radio Frequency Accelerating Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Lane, Peter Gwin [IIT, Chicago

    2016-07-01

    Current designs for muon accelerators require high-gradient radio frequency (RF) cavities to be placed in solenoidal magnetic fields. These fields help contain and efficiently reduce the phase space volume of source muons in order to create a usable muon beam for collider and neutrino experiments. In this context and in general, the use of RF cavities in strong magnetic fields has its challenges. It has been found that placing normal conducting RF cavities in strong magnetic fields reduces the threshold at which RF cavity breakdown occurs. To aid the effort to study RF cavity breakdown in magnetic fields, it would be helpful to have a diagnostic tool which can localize the source of breakdown sparks inside the cavity. These sparks generate thermal shocks to small regions of the inner cavity wall that can be detected and localized using microphones attached to the outer cavity surface. Details on RF cavity sound sources as well as the hardware, software, and algorithms used to localize the source of sound emitted from breakdown thermal shocks are presented. In addition, results from simulations and experiments on three RF cavities, namely the Aluminum Mock Cavity, the High-Pressure Cavity, and the Modular Cavity, are also given. These results demonstrate the validity and effectiveness of the described technique for acoustic localization of breakdown.

  1. Cavity Processing and Preparation of 650 MHz Elliptical Cell Cavities for PIP-II

    Energy Technology Data Exchange (ETDEWEB)

    Rowe, Allan [Fermilab; Chandrasekaran, Saravan Kumar [Fermilab; Grassellino, Anna [Fermilab; Melnychuk, Oleksandr [Fermilab; Merio, Margherita [Fermilab; Reid, Thomas [Argonne (main); Sergatskov, Dmitri [Fermilab

    2017-05-01

    The PIP-II project at Fermilab requires fifteen 650 MHz SRF cryomodules as part of the 800 MeV LINAC that will provide a high intensity proton beam to the Fermilab neutrino program. A total of fifty-seven high-performance SRF cavities will populate the cryomodules and will operate in both pulsed and continuous wave modes. These cavities will be processed and prepared for performance testing utilizing adapted cavity processing infrastructure already in place at Fermilab and Argonne. The processing recipes implemented for these structures will incorporate state-of-the art processing and cleaning techniques developed for 1.3 GHz SRF cavities for the ILC, XFEL, and LCLS-II projects. This paper describes the details of the processing recipes and associated chemistry, heat treatment, and cleanroom processes at the Fermilab and Argonne cavity processing facilities. This paper also presents single and multi-cell cavity test results with quality factors above 5·10¹⁰ and accelerating gradients above 30 MV/m.

  2. HOM study and parameter calculation of the TESLA cavity model

    CERN Document Server

    Zeng, Ri-Hua; Gerigk Frank; Wang Guang-Wei; Wegner Rolf; Liu Rong; Schuh Marcel

    2010-01-01

    The Superconducting Proton Linac (SPL) is the project for a superconducting, high current H-accelerator at CERN. To find dangerous higher order modes (HOMs) in the SPL superconducting cavities, simulation and analysis for the cavity model using simulation tools are necessary. The. existing TESLA 9-cell cavity geometry data have been used for the initial construction of the models in HFSS. Monopole, dipole and quadrupole modes have been obtained by applying different symmetry boundaries on various cavity models. In calculation, scripting language in HFSS was used to create scripts to automatically calculate the parameters of modes in these cavity models (these scripts are also available in other cavities with different cell numbers and geometric structures). The results calculated automatically are then compared with the values given in the TESLA paper. The optimized cavity model with the minimum error will be taken as the base for further simulation of the SPL cavities.

  3. Microfabrication of cavities in polydimethylsiloxane using DRIE silicon molds.

    Science.gov (United States)

    Giang, Ut-Binh T; Lee, Dooyoung; King, Michael R; DeLouise, Lisa A

    2007-12-01

    We present a novel method to create cavities in PDMS that is simple and exhibits wide process latitude allowing control over the radius of curvature to form shallow concave pits or deep spherical cavities.

  4. Theory of optical cavity and laser with output coupling

    OpenAIRE

    氏原, 紀公雄

    2006-01-01

    A quantum-mechanical analysis of an optical cavity having output coupling is presented withapplications to the laser theory. The rigorous treatment of the output coupling allows unifiedanalysis of the optical field inside and outside of the cavity. This treatment had lead to a newexpression for the laser line-width that contained the influences of non-uniform oscillating fielddistribution of the real cavity mode as well as the deviation from the cavity field mode due to non-uniformgain satura...

  5. 47 CFR 97.509 - Administering VE requirements.

    Science.gov (United States)

    2010-10-01

    ..., grandchildren, stepchildren, parents, grandparents, stepparents, brothers, sisters, stepbrothers, stepsisters... accommodate an examinee whose physical disabilities require a special examination procedure. The administering VEs may require a physician's certification indicating the nature of the disability before determining...

  6. Findings from Survey Administered to Weatherization Training Centers

    Energy Technology Data Exchange (ETDEWEB)

    Conlon, Brian [Univ. of Tennessee, Knoxville, TN (United States); Tonn, Bruce Edward [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-03-01

    This report summarizes results of a survey administered to directors of weatherization training centers that receive funding from the U.S. Department of Energy. The survey presents results related to questions on training offered and future plans.

  7. Plasma kinetics of intravenously administered lactose- in-saline in ...

    African Journals Online (AJOL)

    USER

    2010-05-17

    ) the rapid sequestration of homologous desialylated erythrocytes from the blood stream of rabbits has been considerably inhibited by intravenously administered lactose (Muller et al., 1981). More recently, infusion of lactose ...

  8. Follow up after IMRT in oral cavity cancer: update

    Directory of Open Access Journals (Sweden)

    Studer Gabriela

    2012-06-01

    Full Text Available Abstract Purpose Except for early stages (T1/2 N0, the prognosis for patients with oral cavity cancer (OCC is known to be worse than for those with pharyngeal carcinoma. While definitive intensity modulated radiation therapy (IMRT-chemotherapy affords loco-regional control rates (LRC of approximately 80% in advanced pharyngeal cancer, corresponding rates are reported to be much lower for OCC. The aim of this work was to evaluate loco-regional disease control and overall survival (OAS in a relatively large OCC patient cohort treated in the IMRT era. Methods and materials Between October 2002 and June 2011, 160 OCC patients were treated with curative intention IMRT at our department. 122 patients (76% were referred with primary disease and 38 patients (24% with a recurrent OCC at least 3 months after surgery alone. Definitive IMRT was performed in 44/160 patients (28%, whilst 116 patients underwent previous surgery. Simultaneous systemic therapy was administered in 72%. Results Patients with postoperative IMRT (+/−systemic therapy with R0-1 status (n = 99 reached significantly higher LRC/OAS rates than patients following IMRT for macroscopic disease (n = 61, with 84%/80% versus 38%/33% at 3 years, respectively (p  Conclusions IMRT for R0-1 situations translated into a highly significant superior LRC and OAS compared to the IMRT cohort treated for macroscopic disease. Treatment was well tolerated.

  9. Scaling of reactor cavity wall loads and stresses

    International Nuclear Information System (INIS)

    Bohachevsky, I.O.

    1977-11-01

    Scalings of reactor cavity wall loads and stresses are determined by deriving an analytic expression in terms of relevant parameters for each loading induced in the reactor cavity walls by fuel pellet microexplosion and by deriving associated expressions relating resulting stresses to shell thicknesses. Also identified are problems that require additional investigations to obtain satisfactory explicit stress estimates for the reactor cavity walls

  10. Diagnostic Role of Neutrophil-Lymphocyte Ratio in Oral Cavity ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... Aim: In this study, we aimed to evaluate the diagnostic role of neutrophil– lymphocyte ratio (NLR) and other hemogram parameters in differentiating nonmalignant oral cavity lesions from oral cavity cancers. Methods: Ninety- five patients who were performed oral cavity biopsy between the years 2013 and.

  11. Meeting to discuss laser cavity design for photon linear collider ...

    Indian Academy of Sciences (India)

    The design is fairly insensitive to displacements transverse to the beam but very sensitive to change in length of the cavity (as the power enhancement of the laser cavity is lost). In fact an accuracy of less than 1 nm is required, which implies that adaptive optics are required to maintain the cavity enhancement. Power deposit ...

  12. Decoherence in semiconductor cavity QED systems due to phonon couplings

    DEFF Research Database (Denmark)

    Nielsen, Per Kær; Mørk, Jesper

    2014-01-01

    We investigate the effect of electron-phonon interactions on the coherence properties of single photons emitted from a semiconductor cavity QED (quantum electrodynamics) system, i.e., a quantum dot embedded in an optical cavity. The degree of indistinguishability, governing the quantum mechanical...... diagonalization approach. We find that for large cavity decay rates the perturbation theory may break down....

  13. 21 CFR 872.3250 - Calcium hydroxide cavity liner.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Calcium hydroxide cavity liner. 872.3250 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3250 Calcium hydroxide cavity liner. (a) Identification. A calcium hydroxide cavity liner is a device material intended to be applied to the interior of a...

  14. 21 CFR 872.6030 - Oral cavity abrasive polishing agent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Oral cavity abrasive polishing agent. 872.6030... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6030 Oral cavity abrasive polishing agent. (a) Identification. An oral cavity abrasive polishing agent is a device in paste or powder form...

  15. Diagnostic Role of Neutrophil-Lymphocyte Ratio in Oral Cavity ...

    African Journals Online (AJOL)

    Aim: In this study, we aimed to evaluate the diagnostic role of neutrophil– lymphocyte ratio (NLR) and other hemogram parameters in differentiating nonmalignant oral cavity lesions from oral cavity cancers. Methods: Ninetyfive patients who were performed oral cavity biopsy between the years 2013 and 2015 were ...

  16. Use of a fiberscope for examining cavity nests

    Science.gov (United States)

    Kathryn L. Purcell

    1997-01-01

    A system is described that uses a fiberscope to view nests in cavities to provide detailed information on eggs and nestlings. The flexible probe can be inserted around bends, and the tip articulates to allow viewing of the entire cavity and nest. A light guide bundle furnishes light to enable viewing of dark cavities and optical fibers transmit the impage from the lens...

  17. BIOREACTOR WITH LID FOR EASY ACCESS TO INCUBATION CAVITY

    DEFF Research Database (Denmark)

    2012-01-01

    There is provided a bioreactor which is provided with a lid (13) that facilitates access to the incubation cavity. Specifically the end wall of the incubation cavity is constituted by the lid (13) so that removal of the cap renders the incubation cavity fully accessible....

  18. Investigation of free air in peritoneal cavity

    International Nuclear Information System (INIS)

    Park, Sam Gyoun; Park, Bok Hwan; Lee, Dong Hoon; Oh, Jang Suk

    1972-01-01

    On the radiographic findings of simple abdomen, detection of free air in peritoneal cavity indicates a perforation of hollow viscus. In general, free air in abdomen indicate perforation of hollow viscus caused by various disease conditions, i.e. perforation of peptic ulcer, ulcerating malignancy, colon diverticulitis and rupture of pneumatosis cystoides intestinale etc., or by trauma, however it can be rarely noticeable in the cases of intraabdominal infection with overgrowth of gas forming organisms. Eighty eight cases of free air in peritoneal cavity were analysed during the period from July, 1970 to August, 1972 at Kyungpook National University Hospital. As shown in the following tables, various clinical findings were analysed; overview of cases, causating factors and location of rupture, and it's seasonal preponderance

  19. Electro Polishing of Niobium Cavities at DESY

    CERN Document Server

    Matheisen, A; Morales, H; Petersen, B; Schmoekel, M; Steinhau-Kühl, N

    2004-01-01

    At DESY a facility for electro polishing (EP) of the super conducting (s.c.) TESLA/TTF cavities have been built and is operational since summer 2003. The EP infrastructure is capable to handle single-cell structures and the standard TESLA/ TTF nine-cell cavities. Several electro polishing processes have been made since and acceleration voltage up to 40 MV/m have been reached in nine cell structures. We report on measurements and experiences gained since 2003 as well as on handling procedures developed for the preparation of electro polished resonators. Specific data like heat production, variation of current density and bath aging will be presented. Another important point for reproducible results is the quality control of the electro polishing process. First quality control steps to be implanted in the EP procedure for large-scale production will be described.

  20. Multipass optical cavity for inverse Compton interactions

    Energy Technology Data Exchange (ETDEWEB)

    Rollason, A.J. E-mail: a.j.rollason@keele.ac.uk; Fang, X.; Dugdale, D.E

    2004-07-01

    The recycling of laser beams in the focal region of non-resonant multipass optical cavities has been investigated as a means of providing a high intensity of photons for weak interaction experiments. Ray-tracing simulations and measurements with an Ar-ion laser have been carried out to examine the intensity profiles of the laser field in different 2-mirror geometries. In particular, the use of such cavities in the generation of X-rays by inverse Compton scattering is considered. X-ray yields are calculated for electron beams of 0.05, 0.1, 0.2 and 0.5 mm diameter yielding enhancement factors of 10-200 compared to a free space laser interaction.

  1. Postirradiation flap infection about the oral cavity

    International Nuclear Information System (INIS)

    Cabbabe, E.B.; Herbold, D.R.; Sunwoo, Y.C.; Baroudi, I.F.

    1983-01-01

    Postirradiation alteration of oral flora is well documented in the literature. Infection as a complication leading to partial or complete loss of a flap used to reconstruct a defect in the oral cavity is a worrisome outcome. We describe how a flap that was judged clinically to be viable became overwhelmingly infected with the Klebsiella oxytoca, an oral cavity pathogen encountered in this patient following irradiation. Local and systemic changes led to detachment of the flap. This complication may be explained, in view of the absence of venous congestion or arterial ischemia both clinically and pathologically, by the proven contamination of the flap by the Klebsiella pathogen. Local factors resulted in lower resistance and subsequent overwhelming infection. Discussion of the case, review of pertinent literature, and proposed solutions are presented

  2. HOM Couplers for CERN SPL Cavities

    CERN Document Server

    Papke, Kai; Van Rienen, U

    2013-01-01

    Higher-Order-Modes (HOMs) may affect beam stability and refrigeration requirements of superconducting proton linacs such as the SPL, which is studied at CERN as the driver for future neutrino facilities. In order to limit beam-induced HOM effects, CERN considers the use of HOM couplers on the cut-off tubes of the 5-cell superconducting cavities. These couplers consist of resonant antennas shaped as loops or probes, which are designed to couple to modes of a specific frequency range. In this paper the design process is presented and a comparison is made between various design options for the medium and high-beta SPL cavities, both operating at 704.4 MHz. The RF characteristics and thermal behaviour of the various designs are discussed.

  3. Tunable Q-Factor RF Cavity

    Energy Technology Data Exchange (ETDEWEB)

    Balcazar, Mario D. [Fermilab; Yonehara, Katsuya [Fermilab; Moretti, Alfred [Fermilab; Kazakevitch, Gregory [Fermilab

    2018-01-01

    Intense neutrino beam is a unique probe for researching beyond the standard model. Fermilab is the main institution to produce the most powerful and widespectrum neutrino beam. From that respective, a radiation robust beam diagnostic system is a critical element in order to maintain the quality of the neutrino beam. Within this context, a novel radiation-resistive beam profile monitor based on a gasfilled RF cavity is proposed. The goal of this measurement is to study a tunable Qfactor RF cavity to determine the accuracy of the RF signal as a function of the quality factor. Specifically, measurement error of the Q-factor in the RF calibration is investigated. Then, the RF system will be improved to minimize signal error.

  4. Investigation of free air in peritoneal cavity

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sam Gyoun; Park, Bok Hwan; Lee, Dong Hoon; Oh, Jang Suk [Kyungpook National University School of Medicine, Taegu (Korea, Republic of)

    1972-12-15

    On the radiographic findings of simple abdomen, detection of free air in peritoneal cavity indicates a perforation of hollow viscus. In general, free air in abdomen indicate perforation of hollow viscus caused by various disease conditions, i.e. perforation of peptic ulcer, ulcerating malignancy, colon diverticulitis and rupture of pneumatosis cystoides intestinale etc., or by trauma, however it can be rarely noticeable in the cases of intraabdominal infection with overgrowth of gas forming organisms. Eighty eight cases of free air in peritoneal cavity were analysed during the period from July, 1970 to August, 1972 at Kyungpook National University Hospital. As shown in the following tables, various clinical findings were analysed; overview of cases, causating factors and location of rupture, and it's seasonal preponderance.

  5. Heat loss from an open cavity

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, C.G. [California State Polytechnic Univ., Pomona, CA (United States). Coll. of Engineering

    1995-12-01

    Cavity type receivers are used extensively in concentrating solar thermal energy collecting systems. The Solar Total Energy Project (STEP) in Shenandoah, Georgia is a large scale field test for the collection of solar thermal energy. The STEP experiment consists of a large field array of solar collectors used to supplement the process steam, cooling and other electrical power requirements of an adjacent knitwear manufacturing facility. The purpose of the tests, conducted for this study, was to isolate and quantify the radiative, conductive, and convective components of total heat loss, and to determine the effects of operating temperature, receiver angle, and aperture size on cavity heat loss. An analytical model for radiative heat loss was developed and compared with two other methods used to determine radiative heat loss. A proposed convective heat loss correlation, including effects of aperture size, receiver operating temperature, and receiver angle is presented. The resulting data is a source to evaluate the STEP measurements.

  6. HPV and cancer of the oral cavity.

    Science.gov (United States)

    Hübbers, Christian U; Akgül, Baki

    2015-01-01

    Increased awareness of human papillomavirus (HPV) as an etiological cause of head and neck squamous cell carcinoma has increased the interest in analysis of distinct oral sub-sites. It is currently under debate, whether HPV plays a role in the development of squamous cell carcinoma of the oral cavity (OSCC). The weakness in most published studies is the lack of performing different HPV detection tests combined with analysis for biological activity of the virus. In addition, different sub-sites of the oral cavity had been combined to a single entity, which retrospectively leads to a highly heterogeneous basis of data. In this review we mainly discuss the unclear role of HPV in OSCC development.

  7. Dielectric supported radio-frequency cavities

    Science.gov (United States)

    Yu, David U. L.; Lee, Terry G.

    2000-01-01

    A device which improves the electrical and thermomechanical performance of an RF cavity, for example, in a disk-loaded accelerating structure. A washer made of polycrystalline diamond is brazed in the middle to a copper disk washer and at the outer edge to the plane wave transformer tank wall, thus dissipating heat from the copper disk to the outer tank wall while at the same time providing strong mechanical support to the metal disk. The washer structure eliminates the longitudinal connecting rods and cooling channels used in the currently available cavities, and as a result minimizes problems such as shunt impedance degradation and field distortion in the plane wave transformer, and mechanical deflection and uneven cooling of the disk assembly.

  8. Quantum networks based on cavity QED

    Energy Technology Data Exchange (ETDEWEB)

    Ritter, Stephan; Bochmann, Joerg; Figueroa, Eden; Hahn, Carolin; Kalb, Norbert; Muecke, Martin; Neuzner, Andreas; Noelleke, Christian; Reiserer, Andreas; Uphoff, Manuel; Rempe, Gerhard [Max-Planck-Institut fuer Quantenoptik, Hans-Kopfermann-Strasse 1, 85748 Garching (Germany)

    2014-07-01

    Quantum repeaters require an efficient interface between stationary quantum memories and flying photons. Single atoms in optical cavities are ideally suited as universal quantum network nodes that are capable of sending, storing, retrieving, and even processing quantum information. We demonstrate this by presenting an elementary version of a quantum network based on two identical nodes in remote, independent laboratories. The reversible exchange of quantum information and the creation of remote entanglement are achieved by exchange of a single photon. Quantum teleportation is implemented using a time-resolved photonic Bell-state measurement. Quantum control over all degrees of freedom of the single atom also allows for the nondestructive detection of flying photons and the implementation of a quantum gate between the spin state of the atom and the polarization of a photon upon its reflection from the cavity. Our approach to quantum networking offers a clear perspective for scalability and provides the essential components for the realization of a quantum repeater.

  9. Dental Sealants Prevent Cavities PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2016-10-18

    This 60 second public service announcement is based on the October 2016 CDC Vital Signs report. Dental sealants, applied soon after a child's permanent molars come in, can protect against cavities for up to nine years. Applying sealants in schools for low-income children could save millions in dental treatment costs.  Created: 10/18/2016 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 10/18/2016.

  10. Capture cavity II results at FNAL

    Energy Technology Data Exchange (ETDEWEB)

    Branlard, Julien; Chase, Brian; Cancelo, G.; Carcagno, R.; Edwards, H.; Fliller, R.; Hanna, B.; Harms, Elvan; Hocker, A.; Koeth, T.; Kucera, M.; /Fermilab

    2007-06-01

    As part of the research and development towards the International Linear Collider (ILC), several test facilities have been developed at Fermilab. This paper presents the latest Low Level RF (LLRF) results obtained with Capture Cavity II (CCII) at the ILC Test Accelerator (ILCTA) test facility. The main focus will be on controls and RF operations using the SIMCON based LLRF system developed in DESY [1]. Details about hardware upgrades and future work will be discussed.

  11. Single cavity Fabry-Perot modulator enhancements and integrated vertically coupled cavity light-emitting diode

    Science.gov (United States)

    Liu, Daxin

    Fabry-Perot modulators with Multi-Quantum Wells (MQWs) cavities have been studied with great interest during recent years. Usually operating as intensity modulators, these devices have very high modulation contrast ratios, can be operated at very high speed, can be easily made into two dimensional arrays and can be integrated with silicon ICs. They are thus very promising for optical interconnects, optical switching and image processing applications. But before these modulators are to be used in real applications, there are several issues that need to be solved, including the parasitic phase modulation, the bandwidth of such modulators and the alignment of modulator operation wavelength with the wavelength of lasers or light emitting diodes. In this work, the phase properties of Fabry-Perot reflection modulators will be discussed first and an experimental method using a modified Michelson interferometer to characterize the exact phase change will be demonstrated. It is demonstrated that the phase of the reflection light beam from a Fabry-Perot modulator is determined not only by the refractive index change inside the cavity but also by the absorption change inside the cavity. With the purpose of expanding the limited bandwidth of such modulator, devices with short passive cavities are designed and fabricated, the results are described and trade-offs between modulation depth and bandwidth will be discussed. In order to solve the problem of alignment and expand the functionality of Fabry-Perot modulators further, vertically coupled cavity devices with each cavity being electrically controlled independently have been developed. Both a coupled cavity modulator and an integrated light emitting diode with a transmission Fabry-Perot modulator are demonstrated; the first device enhances the modulation bandwidth while the second device has the potential of combining the advantage of high speed operation of MQWs modulators with the long lifetime and low cost of light

  12. Direct Numerical Simulation of Automobile Cavity Tones

    Science.gov (United States)

    Kurbatskii, Konstantin; Tam, Christopher K. W.

    2000-01-01

    The Navier Stokes equation is solved computationally by the Dispersion-Relation-Preserving (DRP) scheme for the flow and acoustic fields associated with a laminar boundary layer flow over an automobile door cavity. In this work, the flow Reynolds number is restricted to R(sub delta*) < 3400; the range of Reynolds number for which laminar flow may be maintained. This investigation focuses on two aspects of the problem, namely, the effect of boundary layer thickness on the cavity tone frequency and intensity and the effect of the size of the computation domain on the accuracy of the numerical simulation. It is found that the tone frequency decreases with an increase in boundary layer thickness. When the boundary layer is thicker than a certain critical value, depending on the flow speed, no tone is emitted by the cavity. Computationally, solutions of aeroacoustics problems are known to be sensitive to the size of the computation domain. Numerical experiments indicate that the use of a small domain could result in normal mode type acoustic oscillations in the entire computation domain leading to an increase in tone frequency and intensity. When the computation domain is expanded so that the boundaries are at least one wavelength away from the noise source, the computed tone frequency and intensity are found to be computation domain size independent.

  13. Quasilinear infiltration from an elliptical cavity

    Science.gov (United States)

    Kuhlman, Kristopher L.; Warrick, Arthur W.

    2008-08-01

    We develop analytic solutions to the linearized steady-state Richards equation for head and total flowrate due to an elliptic cylinder cavity with a specified pressure head boundary condition. They are generalizations of the circular cylinder cavity solutions of Philip [Philip JR. Steady infiltration from circular cylindrical cavities. Soil Sci Soc Am J 1984;48:270-8]. The circular and strip sources are limiting cases of the elliptical cylinder solution, derived for both horizontally- and vertically-aligned ellipses. We give approximate rational polynomial expressions for total flowrate from an elliptical cylinder over a range of sizes and shapes. The exact elliptical solution is in terms of Mathieu functions, which themselves are generalizations of and computed from trigonometric and Bessel functions. The required Mathieu functions are computed from a matrix eigenvector problem, a modern approach that is straightforward to implement using available linear algebra libraries. Although less efficient and potentially less accurate than the iterative continued fraction approach, the matrix approach is simpler to understand and implement and is valid over a wider parameter range.

  14. Coupling superconducting qubits via a cavity bus.

    Science.gov (United States)

    Majer, J; Chow, J M; Gambetta, J M; Koch, Jens; Johnson, B R; Schreier, J A; Frunzio, L; Schuster, D I; Houck, A A; Wallraff, A; Blais, A; Devoret, M H; Girvin, S M; Schoelkopf, R J

    2007-09-27

    Superconducting circuits are promising candidates for constructing quantum bits (qubits) in a quantum computer; single-qubit operations are now routine, and several examples of two-qubit interactions and gates have been demonstrated. These experiments show that two nearby qubits can be readily coupled with local interactions. Performing gate operations between an arbitrary pair of distant qubits is highly desirable for any quantum computer architecture, but has not yet been demonstrated. An efficient way to achieve this goal is to couple the qubits to a 'quantum bus', which distributes quantum information among the qubits. Here we show the implementation of such a quantum bus, using microwave photons confined in a transmission line cavity, to couple two superconducting qubits on opposite sides of a chip. The interaction is mediated by the exchange of virtual rather than real photons, avoiding cavity-induced loss. Using fast control of the qubits to switch the coupling effectively on and off, we demonstrate coherent transfer of quantum states between the qubits. The cavity is also used to perform multiplexed control and measurement of the qubit states. This approach can be expanded to more than two qubits, and is an attractive architecture for quantum information processing on a chip.

  15. Magnetic resonance imaging of syrinx cavity

    International Nuclear Information System (INIS)

    Fukuda, Teruo; Inoue, Yuichi; Nemoto, Yutaka

    1987-01-01

    Syrinx cavity may result from a number of intramedullary tumors or non-neoplastic conditions such as Chiari malformation, trauma and meningitis. The surgical procedure to repair the syrinx is quite different between the cases with spinal cord tumor and without tumor. Therefore, it is important to determine whether syrinx is associated with tumor or not before surgery. We reviewed MR images of 26 cases with syrinx cavity; 20 of which were not associated with tumor (12 Chiari malformation, 5 trauma, 1 meningitis, 1 hydrocephalus, 1 idiopathic) and 6 of which were associated with intramedullary tumor (3 ependymoma, 2 astrocytoma, 1 hemangioendothelioma). The syrinx showed low signal in all 26 cases on T1 weighted images (SE 600/40). All 6 cases with syrinx associated with intramedullary tumor showed high intensity on T2 weighted images (SE 2000/120). On the other hand, the syrinx of 19 of 20 cases with no tumor condition showed reduced intensity on T2 weighted images. Only one post-traumatic small syrinx showed high signal. This was quite different between the cases with spinal cord tumor and without tumor. Therefore, when the syrinx cavity shows high signal on T2 weighted images, an intramedullary tumor is strongly suggested. (author)

  16. Canine oral cavity neoplasias - Brief review

    Directory of Open Access Journals (Sweden)

    João Filipe Requicha

    2015-03-01

    Full Text Available ABSTRACT. Requicha J.F., Pires M. dos A., Albuquerque C.M. & Viegas C.A. [Canine oral cavity neoplasias - Brief review.] Neoplasias da cavidade oral do cão - Breve revisão. Revista Brasileira de Medicina Veterinária, 37(1:41-46, 2015. Faculdade de Medicina Veterinária, Universidade Lusófona de Humanidades e Tecnologias, Campo Grande, 1749-024 Lisboa, Portugal e Department of Veterinary Sciences, School of Agriculture and Veterinary Sciences, University of Trás-os-Montes e Alto Douro, P.O. Box 1013, 5001-801 Vila Real, Portugal. E-mail: jfrequicha@gmail.com Oral proliferative lesions are relatively common in domestic carnivores but, fortunately, a lot of these lesions are benign. The oral cavity is place of 6% of all tumours in dogs, being the sixth most important localization of neoplasias in this specie. The non-odontogenic tumors arise from structures of the oral cavity, except from dental tissue, and they are mostly malignant. Odontogenic tumors are those originated from the dental structures. In the case of tumors of non-odontogenic, will be described the oral papillomatosis, the melanoma, the squamous cell carcinoma, and the fibrosarcoma. Among the odontogenic tumors, the focus will be on the epulides, ameloblastoma, odontoma and dentigerous cysts.

  17. Bioengineering in the oral cavity: our experience

    Directory of Open Access Journals (Sweden)

    Catalfamo L

    2013-10-01

    Full Text Available L Catalfamo,1 E Belli,2 C Nava,1 E Mici,1 A Calvo,1 B D'Alessandro,1 FS De Ponte1 1Unit of Maxillofacial Surgery, University of Messina, Azienda Ospedaliera Universitaria, Policlinico G Martino, Messina, Italy; 2Unit of Maxillofacial Surgery, University Rome Sapienza, Azienda Ospedaliera Sant Andrea, Rome, Italy Background: To date, there are no studies reported in the literature on the possible use of bovine collagen, oxidized regenerated cellulose, or synthetic hyaluronic acid medications in the oral cavity. The aim of this paper is to report the use of bovine collagen, oxidized regenerated cellulose, and synthetic hyaluronic acid medications to improve wound healing in the oral cavity by stimulating granulomatous tissue. Methods: From 2007 to 2011, 80 patients (median age 67 years suffering from oral mucosal lesions participated in this double-blind study. The patients were divided into two groups, each consisting of 40 patients. One group received conventional medications, while the other group of patients were treated with the advanced medications. Results: Advanced medications allowed re-epithelialization of the wound margin in 2–20 days, whereas patients receiving conventional medication showed a median healing duration of 45 days. Conclusion: The results of this study demonstrate that treating oral mucosal wounds with advanced medication has an advantage with regard to wound healing time, allowing patients to have a rapid, functional, and esthetic recovery. Keywords: bioengineering, oral cavity, mucosal recovery

  18. Fundamental tests in Cavity Quantum Electrodynamics

    CERN Multimedia

    CERN. Geneva

    2010-01-01

    At the dawn of quantum physics, Einstein and Bohr had the dream to confine a photon in a box and to use this contraption in order to illustrate the strange laws of the quantum world. Cavity Quantum Electrodynamics has now made this dream real, allowing us to actually achieve in the laboratory variants of the thought experiments of the founding fathers of quantum theory. In our work at Ecole Normale Supérieure, we use a beam of Rydberg atoms to manipulate and probe non-destructively microwave photons trapped in a very high Q superconducting cavity. We realize ideal quantum non-demolition (QND) measurements of photon numbers, observe the radiation quantum jumps due to cavity relaxation and prepare non-classical fields such as Fock and Schrödinger cat states. Combining QND photon counting with a homodyne mixing method, we reconstruct the Wigner functions of these non-classical states and, by taking snapshots of these functions at increasing times, obtain movies of the decoherence process. These experiments ope...

  19. A new awakening for accelerator cavities

    CERN Multimedia

    Katarina Anthony

    2013-01-01

    Imagine: an accelerator unbound by length; one that can bring a beam up to the TeV level in just a few hundred metres. Sounds like a dream? Perhaps not for long. At CERN’s Proton Driven Plasma Wakefield Acceleration Experiment (AWAKE), physicists may soon be working to bring this contemporary fairy-tale to life.   The AWAKE experiment in the CNGS facility. Wherever you find a modern linear particle accelerator, you’ll find with it a lengthy series of RF accelerating cavities. Although based on technology first developed over half a century ago, RF cavities have dominated the accelerating world since their inception. However, new developments in plasma accelerator systems may soon be bringing a new player into the game. By harnessing the power of wakefields generated by beams in plasma cells, physicists may be able to produce accelerator gradients of many GV/m –  hundreds of times higher than those achieved in current RF cavities. “Plasma wakef...

  20. A split-cavity design for the incorporation of a DC bias in a 3D microwave cavity

    NARCIS (Netherlands)

    Cohen, M.A.; Yuan, M.; de Jong, B.W.A.; Beukers, Ewout; Bosman, S.J.; Steele, G.A.

    2017-01-01

    We report on a technique for applying a DC bias in a 3D microwave cavity. We achieve this by isolating the two halves of the cavity with a dielectric and directly using them as DC electrodes. As a proof of concept, we embed a variable capacitance diode in the cavity and tune the resonant

  1. Optical single photons on-demand teleported from microwave cavities

    Science.gov (United States)

    Barzanjeh, Sh; Vitali, D.; Tombesi, P.

    2013-03-01

    We propose a scheme for entangling the optical and microwave output modes of the respective cavities by using a micro mechanical resonator. The micro mechanical resonator, on one side, is capacitively coupled to the microwave cavity and, on the other side, it is coupled to a high-finesses optical cavity. We then show how this continuous variable entanglement can be profitably used to teleport the non-Gaussian number state |1> and the superposition (|0\\rangle +|1\\rangle )/\\sqrt 2 from the microwave cavity output mode onto an output of the optical cavity mode with fidelity much larger than the no-cloning limit.

  2. Control of ring lasers by means of coupled cavities

    DEFF Research Database (Denmark)

    Abitan, Haim; Andersen, Ulrik Lund; Skettrup, Torben

    2000-01-01

    Summary form only. Coupling of optical cavities offers a means of controlling the properties of one cavity (e.g. a laser) by making adjustments to another, external cavity. In this contribution we consider a unidirectional ring laser (bow-tie laser) coupled to an external ring cavity. Using...... different configurations we can control the out-coupling from the ring laser thereby influencing the threshold and the circulating power in the different ring cavities. This may be used to obtain the best balance between the passive losses and a nonlinear loss such as e.g. conversion to the second harmonic...... or operation of an optical parametric oscillator....

  3. Geometrically induced surface polaritons in planar nanostructured metallic cavities

    Energy Technology Data Exchange (ETDEWEB)

    Davids, P. S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Intravia, F [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalvit, Diego A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-01-14

    We examine the modal structure and dispersion of periodically nanostructured planar metallic cavities within the scattering matrix formulation. By nanostructuring a metallic grating in a planar cavity, artificial surface excitations or spoof plasmon modes are induced with dispersion determined by the periodicity and geometric characteristics of the grating. These spoof surface plasmon modes are shown to give rise to new cavity polaritonic modes at short mirror separations that modify the density of modes in nanostructured cavities. The increased modal density of states form cavity polarirons have a large impact on the fluctuation induced electromagnetic forces and enhanced hear transfer at short separations.

  4. Status of the LCLS-II Accelerating Cavity Production

    Energy Technology Data Exchange (ETDEWEB)

    Daly, Ed [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Marhauser, Frank [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Fitzpatrick, Jarrod A. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Palczewski, Ari D. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Preble, Joe [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Wilson, Katherine M. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Grimm, C. J. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Burrill, Andrew B. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Gonnella, Daniel [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2017-05-01

    Cavity serial production for the LCLS-II 4 GeV CM SRF linac has started. A quantity of 266 accelerating cavities has been ordered from two industrial vendors. Jefferson Laboratory leads the cavity procurement activities for the project and has successfully transferred the Nitrogen-Doping process to the industrial partners in the initial phase, which is now being applied for the production cavities. We report on the results from vendor qualification and the status of the cavity production for LCLS-II.

  5. Compression Pad Cavity Heating Augmentation on Orion Heat Shield

    Science.gov (United States)

    Hollis, Brian R.

    2011-01-01

    An experimental study has been conducted to assess the effects of compression pad cavities on the aeroheating environment of the Project Orion Crew Exploration Vehicle heat shield. Testing was conducted in Mach 6 and 10 perfect-gas wind tunnels to obtain heating measurements in and around the compression pads cavities using global phosphor thermography. Data were obtained over a wide range of Reynolds numbers that produced laminar, transitional, and turbulent flow within and downstream of the cavities. The effects of cavity dimensions on boundary-layer transition and heating augmentation levels were studied. Correlations were developed for transition onset and for the average cavity-heating augmentation.

  6. Gas Cavities inside Dust Cavities in Disks Inferred from ALMA Observations

    Science.gov (United States)

    van der Marel, Nienke; van Dishoeck, Ewine F.; Bruderer, Simon; Pinilla, Paola; van Kempen, Tim; Perez, Laura; Isella, Andrea

    2016-01-01

    Protoplanetary disks with cavities in their dust distribution, also named transitional disks, are expected to be in the middle of active evolution and possibly planet formation. In recent years, millimeter-dust rings observed by ALMA have been suggested to have their origin in dust traps, caused by pressure bumps. One of the ways to generate these is by the presence of planets, which lower the gas density along their orbit and create pressure bumps at the edge. We present spatially resolved ALMA Cycle 0 and Cycle 1 observations of CO and CO isotopologues of several famous transitional disks. Gas is found to be present inside the dust cavities, but at a reduced level compared with the gas surface density profile of the outer disk. The dust and gas emission are quantified using the physical-chemical modeling code DALI. In the majority of these disks we find clear evidence for a drop in gas density of at least a factor of 10 inside the cavity, whereas the dust density drops by at least a factor 1000. The CO isotopologue observations reveal that the gas cavities are significantly smaller than the dust cavities. These gas structures suggest clearing by one or more planetary-mass companions.

  7. Rigorous analysis of trapped modes in accelerating cavities

    Directory of Open Access Journals (Sweden)

    Rolf Schuhmann

    2000-12-01

    Full Text Available We report the development of different algorithms for the calculation of quality factors of eigenmodes in accelerating cavities, which have resonance frequencies above the cutoff frequency of the beam tubes. The analysis is based on a discretization of such cavity structures by the finite integration technique, and the radiation at the open boundaries is systematically taken into account by different approaches in time and frequency domain. Results indicate that even single cell cavities of the TESLA type show Q values of 10^{3} and multicell cavities values in excess of 10^{4}. Thus these modes may cause considerable beam instabilities. Comparison with the conventional method of analyzing closed cavities and identifying modes with little change in frequency as a function of boundary condition shows qualitative differences. Some modes from the closed cavity model do not exist in the open structure and thus would be misinterpreted as trapped modes when only a closed cavity analysis is employed.

  8. Radiation-pressure-mediated control of an optomechanical cavity

    Science.gov (United States)

    Cripe, Jonathan; Aggarwal, Nancy; Singh, Robinjeet; Lanza, Robert; Libson, Adam; Yap, Min Jet; Cole, Garrett D.; McClelland, David E.; Mavalvala, Nergis; Corbitt, Thomas

    2018-01-01

    We describe and demonstrate a method to control a detuned movable-mirror Fabry-Pérot cavity using radiation pressure in the presence of a strong optical spring. At frequencies below the optical spring resonance, self-locking of the cavity is achieved intrinsically by the optomechanical (OM) interaction between the cavity field and the movable end mirror. The OM interaction results in a high rigidity and reduced susceptibility of the mirror to external forces. However, due to a finite delay time in the cavity, this enhanced rigidity is accompanied by an antidamping force, which destabilizes the cavity. The cavity is stabilized by applying external feedback in a frequency band around the optical spring resonance. The error signal is sensed in the amplitude quadrature of the transmitted beam with a photodetector. An amplitude modulator in the input path to the cavity modulates the light intensity to provide the stabilizing radiation pressure force.

  9. Informationally administered reward enhances intrinsic motivation in schizophrenia.

    Science.gov (United States)

    Lee, Hyeon-Seung; Jang, Seon-Kyeong; Lee, Ga-Young; Park, Seon-Cheol; Medalia, Alice; Choi, Kee-Hong

    2017-10-01

    Even when individuals with schizophrenia have an intact ability to enjoy rewarding moments, the means to assist them to translate rewarding experiences into goal-directed behaviors is unclear. The present study sought to determine whether informationally administered rewards enhance intrinsic motivation to foster goal-directed behaviors in individuals with schizophrenia (SZ) and healthy controls (HCs). Eighty-four participants (SZ=43, HCs=41) were randomly assigned to conditions involving either a performance-contingent reward with an informationally administered reward or a task-contingent reward with no feedback. Participants were asked to play two cognitive games of equalized difficulty. Accuracy, self-reported intrinsic motivation, free-choice intrinsic motivation (i.e., game play during a free-choice observation period), and perceived competency were measured. Intrinsic motivation and perceived competency in the cognitive games were similar between the two participant groups. The informationally administered reward significantly enhanced self-reported intrinsic motivation and perceived competency in both the groups. The likelihood that individuals with schizophrenia would play the game during the free-choice observation period was four times greater in the informationally administered reward condition than that in the no-feedback condition. Our findings suggest that, in the context of cognitive remediation, individuals with schizophrenia would benefit from informationally administered rewards. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Comparison of an interviewer-administered with an automated self-administered 24 h (ASA24) dietary recall in adolescents.

    Science.gov (United States)

    Hughes, Ashley R; Summer, Suzanne S; Ollberding, Nicholas J; Benken, Laura A; Kalkwarf, Heidi J

    2017-12-01

    The current pilot study aimed to assess whether reporting quality would decline materially in adolescents completing weekly web-based Automated Self-Administered 24-Hour dietary recalls (ASA24-Kids-2014) and interviewer-administered 24 h dietary recalls for six weeks. We also aimed to assess method preference. We conducted two studies. Study 1 (n 20) randomized participants to complete either one ASA24-Kids-2014 or one interviewer-administered recall weekly, for six weeks. Energy intake and number of foods reported were described for each method over time. Differences between recall methods for each measure were tested using mixed-effects regression. Study 2 (n 10) employed a randomized crossover design to describe method preference. Dietary intake was collected either by telephone (interviewer-administered dietary recalls) or via the Internet (ASA24-Kids-2014 dietary recalls). Adolescents aged 12-17 years with no prior diet recording experience were enrolled. In Study 1, mean (sd) total energy and number of foods reported decreased by 50 (222) kJ (12 (53) kcal) and 0·05 (0·31) items v. 38 (138) kJ (9 (33) kcal) and 0·17 (0·14) items per recall for participants randomized to the ASA24-Kids-2014 v. interviewer-administered recalls, respectively. There was no difference between groups for either measure (P > 0·57). In Study 2, eight of ten participants preferred the interviewer-administered recall over the ASA24-Kids-2014. Overall, seven of twenty participants experienced technical difficulties with the ASA24-Kids-2014. No appreciable decay in reporting quality was seen for either method. However, participants reported a preference for the interviewer-administered recall. Our findings can help inform and support larger studies to further characterize the performance of the ASA24 in adolescents.

  11. Administering chemotherapy in nononcology settings: a case study.

    Science.gov (United States)

    Smith, Nancy

    2011-08-01

    Providing chemotherapy for patients in a variety of settings may be a challenge for oncology nurses. Increased acuity and comorbidities of patients needing chemotherapy have resulted in a greater incidence of administration in nononcology settings, such as intensive care units (ICUs). In addition, patients with conditions other than cancer are receiving chemotherapy. Because of a lack of certified and experienced chemotherapy nurses in the ICU, oncology nurses may be pulled from their unit to administer chemotherapy. Another possibility is that nonchemotherapy-certified nurses may be asked to administer chemotherapy. Caring for patients receiving chemotherapy may be stressful for nononcology nurses because of their lack of knowledge regarding chemotherapy precautions and the management of side effects and toxicities. Not only is coordination and cooperation between nursing personnel vital, certified oncology nurses must be able to assess the situation, provide the necessary information and education, and safely administer the chemotherapy. This article describes a case study and provides suggestions for planning in similar situations.

  12. Effects of cavity-cavity interaction on the entanglement dynamics of a generalized double Jaynes-Cummings model

    Science.gov (United States)

    Pandit, Mahasweta; Das, Sreetama; Singha Roy, Sudipto; Shekhar Dhar, Himadri; Sen, Ujjwal

    2018-02-01

    We consider a generalized double Jaynes-Cummings model consisting of two isolated two-level atoms, each contained in a lossless cavity that interact with each other through a controlled photon-hopping mechanism. We analytically show that at low values of such a mediated cavity-cavity interaction, the temporal evolution of entanglement between the atoms, under the effects of cavity perturbation, exhibits the well-known phenomenon of entanglement sudden death (ESD). Interestingly, for moderately large interaction values, a complete preclusion of ESD is achieved, irrespective of its value in the initial atomic state. Our results provide a model to sustain entanglement between two atomic qubits, under the adverse effect of cavity induced perturbation, by introducing a non-intrusive inter-cavity photon exchange that can be physically realized through cavity-QED setups in contemporary experiments.

  13. Elliptical superconducting RF cavities for FRIB energy upgrade

    Science.gov (United States)

    Ostroumov, P. N.; Contreras, C.; Plastun, A. S.; Rathke, J.; Schultheiss, T.; Taylor, A.; Wei, J.; Xu, M.; Xu, T.; Zhao, Q.; Gonin, I. V.; Khabiboulline, T.; Pischalnikov, Y.; Yakovlev, V. P.

    2018-04-01

    The multi-physics design of a five cell, βG = 0 . 61, 644 MHz superconducting elliptical cavity being developed for an energy upgrade in the Facility for Rare Isotope Beams (FRIB) is presented. The FRIB energy upgrade from 200 MeV/u to 400 MeV/u for heaviest uranium ions will increase the intensities of rare isotope beams by nearly an order of magnitude. After studying three different frequencies, 1288 MHz, 805 MHz, and 644 MHz, the 644 MHz cavity was shown to provide the highest energy gain per cavity for both uranium and protons. The FRIB upgrade will include 11 cryomodules containing 5 cavities each and installed in 80-meter available space in the tunnel. The cavity development included extensive multi-physics optimization, mechanical and engineering analysis. The development of a niobium cavity is complete and two cavities are being fabricated in industry. The detailed design of the cavity sub-systems such as fundamental power coupler and dynamic tuner are currently being pursued. In the overall design of the cavity and its sub-systems we extensively applied experience gained during the development of 650 MHz low-beta cavities at Fermi National Accelerator Laboratory (FNAL) for the Proton Improvement Plan (PIP) II.

  14. Photoprocesses of photosensitizing drugs within cyclodextrin cavities.

    Science.gov (United States)

    Monti, Sandra; Sortino, Salvatore

    2002-09-01

    Recently some interest has been focused on the photobehavior of CD-drug inclusion complexes in relation to the problem of the biological photosensitization by drugs. This review is dedicated to the illustration of the mechanistic aspects of the photoprocesses occurring in some non-steroidal anti-inflammatory drugs (NSAIDs), with photosensitising side effects, within CD cavities. It is shown how the photobehavior of the CD-drug associates can help to model the photoreactivity of the drugs in biological sites. The limitations for the use of CDs as protective systems for the clinical administration of photosensitising drugs is also evidenced.

  15. Criteria for vacuum breakdown in rf cavities

    International Nuclear Information System (INIS)

    Peter, W.; Faehl, R.J.; Kadish, A.; Thode, L.E.

    1983-01-01

    A new high-voltage scaling based on Kilpatrick's criterion is presented that suggests that voltages more than twice the Kilpatrick limit can be obtained with identical initial conditions of vacuum and surface cleanliness. The calculations are based on the experimentally observed decrease in secondary electron emission with increasing ion-impact energy above 100 keV. A generalized secondary-emission package has been developed to simulate actual cavity dynamics in conjunction with our 2 1/2-dimensional fully electromagnetic particle-in-cell code CEMIT. The results are discussed with application to the suppression of vacuum breakdown in rf accelerator devices

  16. Wave Dynamical Chaos in Superconducting Microwave Cavities

    CERN Document Server

    Rehfeld, H; Dembowski, C; Gräf, H D; Hofferbert, R; Richter, A; Lengeler, Herbert

    1997-01-01

    During the last few years we have studied the chaotic behavior of special Euclidian geometries, so-called billiards, from the quantum or in more general sense "wave dynamical" point of view. Due to the equivalence between the stationary Schroedinger equation and the classical Helmholtz equation in the two-dimensional case (plain billiards), it is possible to simulate "quantum chaos" with the help of macroscopic, superconducting microwave cavities. Using this technique we investigated spectra of three billiards from the family of Pascal's Snails (Robnik-Billiards) with a different chaoticity in each case in order to test predictions of standard stochastical models for classical chaotic systems.

  17. Giant Submandibular Calculus Eroding Oral Cavity Mucosa

    Directory of Open Access Journals (Sweden)

    Eng Haw Lim

    2017-09-01

    Full Text Available Sialolithiasis is the formation of calculi or sialoliths in the salivary gland. It is the most common benign condition of the salivary gland. Sialolithiasis can occur in all salivary glands. The submandibular gland is most commonly affected followed by the parotid gland. Calculi commonly measure less than 10 mm. Calculi of more than 15 mm are termed giant salivary gland calculi and are infrequently reported in the literature. Here, we report a case of unusually large submandibular gland calculus of 5 cm in greatest dimension which caused erosion of the oral cavity.

  18. Fiberoptic microphone using a polymeric cavity

    Science.gov (United States)

    Wang, Wei-Chih; Soetanto, William; Gu, Kebin

    2011-04-01

    The fabrication and experimental investigation of a fiberoptic microphone is described. The sensing element is a silicon diaphragm with gold thin film coating that is positioned inside a silicone rubber mold at the end of a single mode optical fiber. Thus, a Fabry-Perot interferometer is formed between the inner fiber and the diaphragm. An acoustic pressure change is detected by using the developed microphone. The polymeric cavity and silicon diaphragm-based system exhibits excellent physicochemical properties with a small, simple, low cost, and lightweight design. The system is also electromagnetic interference / radio frequency interference immunity due to the use of fiberoptics.

  19. Giant Submandibular Calculus Eroding Oral Cavity Mucosa.

    Science.gov (United States)

    Lim, Eng Haw; Nadarajah, Sanjeevan; Mohamad, Irfan

    2017-09-01

    Sialolithiasis is the formation of calculi or sialoliths in the salivary gland. It is the most common benign condition of the salivary gland. Sialolithiasis can occur in all salivary glands. The submandibular gland is most commonly affected followed by the parotid gland. Calculi commonly measure less than 10 mm. Calculi of more than 15 mm are termed giant salivary gland calculi and are infrequently reported in the literature. Here, we report a case of unusually large submandibular gland calculus of 5 cm in greatest dimension which caused erosion of the oral cavity.

  20. Intra-cavity vortex beam generation

    CSIR Research Space (South Africa)

    Naidoo, Darryl

    2011-08-01

    Full Text Available in Fig. 3. For a Gaussian pump beam (Fig. 4(a)) we achieved a Gaussian output (Fig. 4(b)) and for a ring shaped pump beam (Fig. 4(c)) we achieved a LG01 (Fig. 4(d)) eigenmode of pure modal quality. The idea of pump shaping is employed to a plano... plano-concave laser cavity with a ring shaped pump intensity profile. The beam shaping element could be removed to revert back to the Gaussian pump scenario. Proc. of SPIE Vol. 8130 813009-4 Downloaded from SPIE Digital Library on 30 Sep 2011...

  1. Interacting collective modes in a laser cavity

    International Nuclear Information System (INIS)

    Graca, E.L.; Brito, A.L. de; Baseia, B.

    1985-01-01

    Collective operators are defined for the quantized radiation field in a one-dimensional laser cavity coupled to a semi-infinite outside region and the overlaps of neighbouring collective modes are considered to show how they modify, in the linear appoximation, the time evolution of the radiation field below threshold. The model and procedure work directly within a continuous spectrum of modes and allow us to get an improved insight on the prescription for the laser field in single-mode operation. (Author) [pt

  2. Cavity enhanced rephased amplified spontaneous emission

    International Nuclear Information System (INIS)

    A Williamson, Lewis; J Longdell, Jevon

    2014-01-01

    Amplified spontaneous emission is usually treated as an incoherent noise process. Recent theoretical and experimental work using rephasing optical pulses has shown that rephased amplified spontaneous emission (RASE) is a potential source of wide bandwidth time-delayed entanglement. Due to poor echo efficiency the plain RASE protocol does not in theory achieve perfect entanglement. Experiments done to date show a very small amount of entanglement at best. Here we show that RASE can, in principle, produce perfect multimode time-delayed two mode squeezing when the active medium is placed inside a Q-switched cavity. (paper)

  3. Superconducting RF Cavities Past, Present and Future

    CERN Document Server

    Chiaveri, Enrico

    2003-01-01

    In the last two decades many laboratories around the world, notably Argonne (ANL), TJNAF (formerly CEBAF), CERN, DESY and KEK, decided to develop the technology of superconducting (SC) accelerating cavities. The aim was either to increase the accelerator energy or to save electrical consumption or both. This technology has been used extensively in the operating machines showing good performances and strong reliability. At present, the technology using bulk niobium (Nb) or Nb coated on copper (Cu) is mature enough to be applied for many different applications, such as synchrotron light sources and spallation neutron drivers. Results, R&D work and future projects will be presented with emphasis on application to linear accelerators.

  4. A Rare Tumor of Nasal Cavity: Glomangiopericytoma

    Directory of Open Access Journals (Sweden)

    Aysegul Verim

    2014-01-01

    Full Text Available Glomangiopericytoma is a rare vascular neoplasm characterized by a pattern of prominent perivascular growth. A 72-year-old woman was admitted to our clinic complaining of nasal obstruction, frequent epistaxis, and facial pain. A reddish tumor filling the left nasal cavity was observed on endoscopy and treated with endoscopic excision. Microscopically, closely packed cells interspersed with numerous thin-walled, branching staghorn vessels were seen. Glomangiopericytoma is categorized as a borderline low malignancy tumor by WHO classification. Long-term follow-up with systemic examination is necessary due to high risk of recurrence.

  5. Different optical properties in different periodic slot cavity geometrical morphologies

    Science.gov (United States)

    Zhou, Jing; Shen, Meng; Du, Lan; Deng, Caisong; Ni, Haibin; Wang, Ming

    2016-09-01

    In this paper, optical properties of two-dimensional periodic annular slot cavity arrays in hexagonal close-packing on a silica substrate are theoretically characterized by finite difference time domain (FDTD) simulation method. By simulating reflectance spectra, electric field distribution, and charge distribution, we confirm that multiple cylindrical surface plasmon resonances can be excited in annular inclined slot cavities by linearly polarized light, in which the four reflectance dips are attributed to Fabry-Perot cavity resonances in the coaxial cavity. A coaxial waveguide mode TE11 will exist in these annular cavities, and the wavelengths of these reflectance dips are effectively tailored by changing the geometrical pattern of slot cavity and the dielectric materials filled in the cavities. These resonant wavelengths are localized in annular cavities with large electric field enhancement and dissipate gradually due to metal loss. The formation of an absorption peak can be explained from the aspect of phase matching conditions. We observed that the proposed structure can be tuned over the broad spectral range of 600-4000 nm by changing the outer and inner radii of the annular gaps, gap surface topography. Meanwhile, different lengths of the cavity may cause the shift of resonance dips. Also, we study the field enhancement at different vertical locations of the slit. In addition, dielectric materials filling in the annular gaps will result in a shift of the resonance wavelengths, which make the annular cavities good candidates for refractive index sensors. The refractive index sensitivity of annular cavities can also be tuned by the geometry size and the media around the cavity. Annular cavities with novel applications can be implied as surface enhanced Raman spectra substrates, refractive index sensors, nano-lasers, and optical trappers. Project supported by the National Natural Science Foundation of China (Grant No. 61178044), the Natural Science Foundation

  6. Progress on SCRF cavity manufacturing activities at RRCAT

    International Nuclear Information System (INIS)

    Puntambekar, A.; Dwivedi, J.; Mundra, G.; Srivastava, P.; Joshi, S.C.; Gupta, P.D.

    2015-01-01

    The work on development of SCRF cavities and associated technologies is ongoing at RRCAT to support its upcoming projects involving SC LINAC. RRCAT is also a member of Indian Institution Fermilab Collaboration (IIFC) working on development of SCRF cavities and associated technologies. Subsequent to 1.3 GHz single cell SCRF cavities, a 650 MHz single cell, a 1.3 GHz five cell and a 1.3 GHz nine cell SCRF cavities have been fabricated. These were tested for their mechanical, vacuum and RF qualifications at RRCAT for pre qualifications. The 1.3 GHz five cell SCRF cavity and 650 MHz single cell SCRF cavity has been processed and successfully tested at Fermi lab under IIFC. The 1.3 GHz five-cell cavity has achieved E acc of 20.3 MV/m at 2 K and 42 MV/m at 1.5-1.7 K with Q o of 2 x 10 10 . The 650 MHz single cell cavity has achieved the E acc > 19.3 MV/m with Q> 4x 10 10 at 2K. A 15 kW Electron Beam Welding (EBW) Machine has also been installed and commissioned at RRCAT as part of special infrastructure for development of SCRF cavities. One each 1.3 GHz and 650 MHz single cell SCRF cavities have also been fabricated using this EBW facility. Present focus of work is towards development of 650 MHz (β=0.92) multi-cell SCRF cavities. This paper will present the various technology development efforts on SCRF cavity fabrication, cavity test results and future plans. (author)

  7. Effect of lead acetate administered orally at different dosage levels ...

    African Journals Online (AJOL)

    The project was conducted to evaluate the effect of lead administered as lead acetate at different dosage levels via drinking water in broiler chicks. Thirty-five healthy chicks were divided into seven groups (five chicks each) and one group was kept as un-medicated control. Groups A, B, C, D, E and F were medicated with ...

  8. Teaching Auction Strategy Using Experiments Administered Via the Internet

    Science.gov (United States)

    Asker, John; Grosskopf, Brit; McKinney, C. Nicholas; Niederle, Muriel; Roth, Alvin E.; Weizsacker, Georg

    2004-01-01

    The authors present an experimental design used to teach concepts in the economics of auctions and implications for e-Business procurement. The experiment is easily administered and can be adapted to many different treatments. The chief innovation is that it does not require the use of a lab or class time. Instead, the design can be implemented on…

  9. Challenges of Administering Teacher Education Programme in Kenyan Universities

    Science.gov (United States)

    Genvieve, Nasimiyu

    2017-01-01

    Proper management of logistical issues in Teacher education programme tends to promote the quality of preparation of school teachers. The main objective of the study was to investigate challenges of administering teacher education programmes in Kenyan universities. The theoretical framework of the study was adopted as used by Koehler and Mishra's…

  10. 40 CFR 147.1100 - State-administered program.

    Science.gov (United States)

    2010-07-01

    .... (c) Statement of legal authority. “Underground Injection Control Program—Attorney General's Statement... Section 147.1100 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) STATE, TRIBAL, AND EPA-ADMINISTERED UNDERGROUND INJECTION CONTROL PROGRAMS Massachusetts § 147...

  11. 40 CFR 147.1300 - State-administered program.

    Science.gov (United States)

    2010-07-01

    ... Section 147.1300 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) STATE, TRIBAL, AND EPA-ADMINISTERED UNDERGROUND INJECTION CONTROL PROGRAMS Missouri § 147.1300...) Opinion Letter No. 63 and attached Memorandum Opinion, signed by Attorney General of Missouri, March 16...

  12. 40 CFR 147.1900 - State-administered program.

    Science.gov (United States)

    2010-07-01

    ... Injection Control Program Legal Counsel's Statement,” October 1983, signed by the Assistant Attorney General... Section 147.1900 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) STATE, TRIBAL, AND EPA-ADMINISTERED UNDERGROUND INJECTION CONTROL PROGRAMS Oregon § 147.1900...

  13. Comparison between fish and linseed oils administered orally for ...

    African Journals Online (AJOL)

    The objective of this study was to compare the efficacy of two sources of omega 3 and 6, fish oil (FO) and linseed oil (LO), orally administered, alone or in combination, for treating experimentally induced keratoconjunctivitis sicca (KCS) in rabbits. Twenty-eight New Zealand rabbits were used in this study. Seven animals ...

  14. Potency Studies of live- Attenuated Viral Vaccines Administered in ...

    African Journals Online (AJOL)

    We critically carried out a potency study in 1992 and 1997 on measles and poliovirus vaccines administered at five different vaccination centers in the metropolitan Lagos, Nigeria. using WHO guidelines on titration of live- viral vaccines, our results revealed that only 6 (16.7%) of 36 measles vaccine (MV) vials and 11 ...

  15. Statistical analysis of Japanese Thorotrast-administered autopsy cases

    International Nuclear Information System (INIS)

    Mori, T.; Kato, Y.; Shimamine, T.; Watanabe, S.

    1979-01-01

    The causes of death of 144 Japanese autopsy cases during 1945-1975, who had been intravascularly injected with Thorotrast in life, were compared with those of non-Thorotrast-administered autopsy cases in the same age bracket, recorded in the Annals of Japanese Pathological Autopsy Cases during 1958-1973. This comparison revealed that the incidence of malignant hepatic tumors was more than 10 times higher in the Thorotrast-administered cases. The increase was attributable to an increased incidence of hemangioendothelioma and cholangiocarcinoma of the liver. The only significant increase of liver cirrhosis found to exist in the Thorotrast group occurred in the female cases. Some of the Thorotrast-administered cases were found to have developed myeloid leukemia and erythroleukemia. There was also a significant increase in the number of cases of aplastic anemia in the Thorotrast group, but clinically and pathologically these were atypical. Lymphatic leukemia was not observed. No significant difference was found in the incidence of either malignant lymphomas or osteosarcomas in the Thorotrast group and the controls. Lung cancer, on the other hand, showed a significantly higher incidence among the controls than among the Thorotrast-administered cases

  16. 40 CFR 282.50 - Alabama State-Administered Program.

    Science.gov (United States)

    2010-07-01

    ... financial responsibility for hazardous substance underground storage tank systems. (2) Statement of legal... administered by the Alabama Department of Environmental Management, was approved by EPA pursuant to 42 U.S.C... obtained from the Ground Water Branch, Alabama Department of Environmental Management, 1751 W.L. Dickinson...

  17. Biochemical effects on the liver and kidney of rats administered ...

    African Journals Online (AJOL)

    The effects of aqueous extract of ximenia Americana stem bark on liver and kidney of albino rats was investigated. Different doses of the crude extract were administered to rats for 30 consecutive days. The levels of serum aspartate aminotransferase (AST) and alanine aminotransferase (ALT) of treated animals significantly ...

  18. 40 CFR 147.2500 - State-administered program.

    Science.gov (United States)

    2010-07-01

    ... State-administered program: (1) Chapter 144, Water, Sewage, Refuse, Mining and Air Pollution, Wisconsin... Section 147.2500 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS... Treatment Works, Wisconsin Administrative Code § 210.05 Natural Resources Board Order No. WQ-25-82, approved...

  19. Erythrocyte osmotic fragility of pigs administered ascorbic acid and ...

    African Journals Online (AJOL)

    The experiment was carried out with the aim of investigating the effect of an antioxidant ascorbic acid on erythrocyte osmotic fragility of pigs transported by road for 4 h during the harmattan season. 16 pigs administered with ascorbic acid at the dose of 250 mg/kg per os and individually served as experimental animals and ...

  20. 40 CFR 147.3000 - EPA-administered program.

    Science.gov (United States)

    2010-07-01

    ... Section 147.3000 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) STATE, TRIBAL, AND EPA-ADMINISTERED UNDERGROUND INJECTION CONTROL PROGRAMS Lands of the Navajo... Utah. This program consists of the UIC program requirements of 40 CFR parts 124, 144, 146, 148, and...

  1. The role of intraperitoneally administered vitamin C during ...

    African Journals Online (AJOL)

    The effects of daily intraperitoneally administered doses of 100 mg/kg bd. wt. vitamin C on levels of some endogenous antioxidants as well as hepatic and renal function were investigated in a group of rabbits infected with a strain of Trypanosoma congolense (strain number: BS2/TC /SP28/P4). Values of parameters ...

  2. Impact of Methods of Administering Growth-Stage Deficit Irrigation ...

    African Journals Online (AJOL)

    ABSRACT: Field experiments were conducted in 2009/10 and 2010/11 irrigation seasons at the Institute for. Agricultural Research, Samaru Zaria, to assess the impact of two methods of administering Growth-stage deficit irrigation scheduling (GSDIS) on yield and soil water balance of an early maturing maize variety.

  3. Pharmacokinetics of orally administered tramadol in domestic rabbits (Oryctolagus cuniculus).

    Science.gov (United States)

    Souza, Marcy J; Greenacre, Cheryl B; Cox, Sherry K

    2008-08-01

    To determine the pharmacokinetics of an orally administered dose of tramadol in domestic rabbits (Oryctolagus cuniculus). 6 healthy adult sexually intact female New Zealand White rabbits. Physical examinations and plasma biochemical analyses were performed to ensure rabbits were healthy prior to the experiment. Rabbits were anesthetized with isoflurane, and IV catheters were placed in a medial saphenous or jugular vein for collection of blood samples. One blood sample was collected before treatment with tramadol. Rabbits were allowed to recover from anesthesia a minimum of 1 hour before treatment. Then, tramadol (11 mg/kg, PO) was administered once, and blood samples were collected at various time points up to 360 minutes after administration. Blood samples were analyzed with high-performance liquid chromatography to determine plasma concentrations of tramadol and its major metabolite (O-desmethyltramadol). No adverse effects were detected after oral administration of tramadol to rabbits. Mean +/- SD half-life of tramadol after administration was 145.4 +/- 81.0 minutes; mean +/- SD maximum plasma concentration was 135.3 +/- 89.1 ng/mL. Although the dose of tramadol required to provide analgesia in rabbits is unknown, the dose administered in the study reported here did not reach a plasma concentration of tramadol or O-desmethyltramadol that would provide sufficient analgesia in humans for clinically acceptable periods. Many factors may influence absorption of orally administered tramadol in rabbits.

  4. A tunable waveguide to cavity coupler for high power accelerator cavities

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Rajesh, E-mail: krajesh@barc.gov.in [LEHIPA, Physics Group, Bhabha Atomic Research Centre, Mumbai 400085 (India); Singh, P. [LEHIPA, Physics Group, Bhabha Atomic Research Centre, Mumbai 400085 (India); Unnikrishnan, Divya; Kumar, Girish [Department of Electrical Engineering, IIT Bombay, Mumbai 400076 (India)

    2012-02-01

    The end iris ridge waveguide couplers are used to couple power to accelerator cavities through a reduced size coupling port. However, higher electric and magnetic fields due to reduced size lead to strict requirements on dimensional tolerances during coupler fabrication process. It is shown by detailed parametric analysis that even small dimensional changes during manufacturing or operation can lead to undesired shift in design frequency and deterioration of return loss. Hence, transmitted power testing of two couplers connected back to back without an intermediate cavity cannot be carried out. Here, we propose cylindrical static tuners on impedance matching section to relax the dimensional tolerance requirements. It is also shown that an iris coupled coupler-cavity system is more tolerant towards coupler dimensional changes than a stand-alone coupler. However, same tuners can find use for tuning the coupling coefficient of coupler-cavity system. The proposed tuning scheme is expected to reduce the coupler manufacturing costs and provide an useful alternative for coupling coefficient tuning over iris machining.

  5. Development of oral cavity inspecting system

    Science.gov (United States)

    Zhang, Hongxia; Wu, Di; Jia, Dagong; Zhang, Yimo

    2009-11-01

    An oral cavity inspecting system is designed and developed to inspect the detail of teeth. The inspecting system is composed of microscopic imaging part, illuminating part, image capture and processing, display part. The two groups of cemented lenses were optimized to minimize the optical aberration and the collimated beam light is gotten between the two lenses. A relay lens is adopted to allow the probe to access the oral cavity depth. The illumination optic fiber is used and the brightness and color temperature can be adjustable. The illumination fiber end surface is oblique cut and the optimum angle is 37°. The image of teeth is imaged on CMOS and captured into computer. The illumination intensity and uniformity were tested and the proper parameter is set. Foucault chart was observed and the system resolution is higher than 100lp/mm. The oral inspecting system is used to test standard tooth model and patho-teeth model. The tooth image is clear and the details can be observed. The experimental results show that the system could meet dental medical application requirements.

  6. Polarization dynamics of VCSELs in external cavities

    Science.gov (United States)

    Marconi, M.; Javaloyes, J.; Barland, S.; Balle, S.; Giudici, M.

    2014-05-01

    We review the dynamics of VCSELs that experience both Polarization-Selective Feedback (PSF) and Crossed- Polarization Reinjection (XPR). Different regimes of regular pulsation were found. For strong enough XPR levels, the VCSEL emission in each of its linearly-polarized components displays a square-wave modulation which regularity is greatly enhanced by small levels of PSF. Such a square-wave is in antiphase for the two polarizations, and it turns out to be stable and robust over broad intervals of current. The frequency of the square-wave is determined by the length of the XPR arm. For weak levels of PSF and XPR, the VCSEL emits a regular train of short optical pulses arising from the locking of the modes in the PSF cavity. The frequency of the pulse train is stable on short time scales, but it wanders with a characteristic time scale of hundreds of roundtrips in the PSF cavity. The experimental results are successfully explained by an extension of the Spin-Flip Model that incorporates gain saturation and the effects of PSF and XPR.

  7. VERY HIGH RESOLUTION RF CAVITY BPM

    Energy Technology Data Exchange (ETDEWEB)

    Ross, Marc C

    2003-05-27

    Linear collider (LC) interaction region beam sizes and component position stability requirements are expected to be a few nanometers[1]. It is important to show that the related tolerances can be achieved, with an electron beam if possible. Using recently developed component stabilization technology, very high-resolution beam position monitors (BPM's), and the ultra-low emittance beam at the KEK ATF, we plan to demonstrate the required stabilization. Our first step is to develop high-resolution RF cavity beam position monitors, using either C or X band frequencies. A C-band cavity BPM with a resolution of 25 nm has been reported in tests at FFTB [2]. By correcting for the effects of non-axial trajectories and using both position and angle BPM movers, we expect to be able to demonstrate a resolution of 2 to 3 nm over a dynamic range of {+-} 20 {micro}m. We report on the progress of the tests here.

  8. Cavity Microwave Searches for Cosmological Axions

    Energy Technology Data Exchange (ETDEWEB)

    Carosi, G; van Bibber, K

    2007-01-22

    This chapter will cover the search for dark matter axions based on microwave cavity experiments proposed by Pierre Sikivie. We will start with a brief overview of halo dark matter and the axion as a candidate. The principle of resonant conversion of axions in an external magnetic field will be described as well as practical considerations in optimizing the experiment as a signal-to-noise problem. A major focus of this chapter will be the two complementary strategies for ultra-low noise detection of the microwave photons--the 'photon-as-wave' approach (i.e. conventional heterojunction amplifiers and soon to be quantum-limited SQUID devices), and 'photon-as-particle' (i.e. Rydberg-atom single-quantum detection). Experimental results will be presented; these experiments have already reached well into the range of sensitivity to exclude plausible axion models, for limited ranges of mass. The section will conclude with a discussion of future plans and challenges for the microwave cavity experiment.

  9. Status of superconducting RF cavity development

    International Nuclear Information System (INIS)

    Shepard, K.W.

    1989-01-01

    For several reasons, a brief historical review seems appropriate at this time. The twenty-fifth anniversary of the first acceleration of beam with a superconducting cavity will occur shortly [1,2,3]. Also, the scope of accelerator applications of superconducting radio-frequency (SRF) devices has, within the last few months, begun to increase rapidly [4] - to the point that it seems likely that early expectations for this technology will largely be fulfilled. Since the object is to accelerate beam, a simple one parameter measure of the technology is the total of how much beam has been accelerated. Figure 1 shows the total accumulated voltage in tests and/or operation of superconducting accelerating cavities with beam, up to the time indicated, as reported in the open literature [4-35]. This parameter has been divided into two terms: first, the subtotal for electron accelerating velocity-of-light structures, and second the subtotal for low-velocity, ion accelerating structures. To restate: each of these terms represents as a function of time an integrated, accumulative total voltage produced by SRF hardware and demonstrated with beam. 56 refs., 4 figs

  10. Porous photonic crystal external cavity laser biosensor

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Qinglan [Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801 (United States); Peh, Jessie; Hergenrother, Paul J. [Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801 (United States); Cunningham, Brian T. [Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801 (United States); Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801 (United States)

    2016-08-15

    We report the design, fabrication, and testing of a photonic crystal (PC) biosensor structure that incorporates a porous high refractive index TiO{sub 2} dielectric film that enables immobilization of capture proteins within an enhanced surface-area volume that spatially overlaps with the regions of resonant electromagnetic fields where biomolecular binding can produce the greatest shifts in photonic crystal resonant wavelength. Despite the nanoscale porosity of the sensor structure, the PC slab exhibits narrowband and high efficiency resonant reflection, enabling the structure to serve as a wavelength-tunable element of an external cavity laser. In the context of sensing small molecule interactions with much larger immobilized proteins, we demonstrate that the porous structure provides 3.7× larger biosensor signals than an equivalent nonporous structure, while the external cavity laser (ECL) detection method provides capability for sensing picometer-scale shifts in the PC resonant wavelength caused by small molecule binding. The porous ECL achieves a record high figure of merit for label-free optical biosensors.

  11. Cavity plasmon polaritons in monolayer graphene

    International Nuclear Information System (INIS)

    Kotov, O.V.; Lozovik, Yu.E.

    2011-01-01

    Plasmon polaritons in a new system, a monolayer doped graphene embedded in optical microcavity, are studied here. The dispersion law for lower and upper cavity plasmon polaritons is obtained. Peculiarities of Rabi splitting for the system are analyzed; particularly, role of Dirac-like spinor (envelope) wave functions in graphene and corresponding angle factors are considered. Typical Rabi frequencies for maximal (acceptable for Dirac-like electron spectra) Fermi energy and frequencies of polaritons near polariton gap are estimated. The plasmon polaritons in considered system can be used for high-speed information transfer in the THz region. -- Highlights: → Plasmon polaritons in a monolayer doped graphene embedded in optical microcavity, are studied here. → The dispersion law for lower and upper cavity plasmon polaritons is obtained. → Peculiarities of Rabi splitting for the system are analyzed. → Role of Dirac-like wave functions in graphene and corresponding angle factors are considered. → Typical Rabi frequencies and frequencies of polaritons near polariton gap are estimated.

  12. Superconducting accelerating cavity for KEK B-factory

    International Nuclear Information System (INIS)

    Furuya, T.; Asano, K.; Mitsunobu, S.; Tajima, T.; Takahashi, T.; Ishi, Y.; Kijima, Y.; Murai, T.; Sennyu, K.

    1996-01-01

    KEKB is an asymmetric collider of 3.5 GeV x 8 GeV with the circulating beams of 2.6 A(e - ) and 1.1 A(e + ). These high currents require the RF cavities which have sufficiently damped higher order modes (HOMs), because RF cavities are the main source of the ring impedance that can cause the single bunch and coupled bunch instabilities. Another problem is a multibunch instability due to the accelerating mode. Two types of accelerating cavities are under development for the RF system of KEKB: a new normal conducting cavity (ARES) and a superconducting (SC) cavity. In this paper, recent activity of an SC accelerating cavity for KEKB is reported. (K.A.)

  13. Optical cavity cooling of mechanical modes of a semiconductor nanomembrane

    DEFF Research Database (Denmark)

    Usami, Koji; Naesby, A.; Bagci, Tolga

    2012-01-01

    Mechanical oscillators can be optically cooled using a technique known as optical-cavity back-action. Cooling of composite metal–semiconductor mirrors, dielectric mirrors and dielectric membranes has been demonstrated. Here we report cavity cooling of mechanical modes in a high-quality-factor and......Mechanical oscillators can be optically cooled using a technique known as optical-cavity back-action. Cooling of composite metal–semiconductor mirrors, dielectric mirrors and dielectric membranes has been demonstrated. Here we report cavity cooling of mechanical modes in a high......-quality-factor and optically active semiconductor nanomembrane. The cooling is a result of electron–hole generation by cavity photons. Consequently, the cooling factor depends on the optical wavelength, varies drastically in the vicinity of the semiconductor bandgap, and follows the excitonic absorption behaviour...... an alternative cooling mechanism that is a result of electronic stress via the deformation potential, and outline future directions for cavity optomechanics with optically active semiconductors....

  14. Construction of 714 MHz HOM-free accelerating cavities.

    Science.gov (United States)

    Sakanaka, S; Hinode, F; Kubo, K; Urakawa, J

    1998-05-01

    A new 'higher-order-mode (HOM)-free' accelerating cavity has been developed which can provide an accelerating voltage of more than 400 kV per cavity at a frequency of 714 MHz. The harmful HOMs in the cavities, which can induce beam instabilities at high beam currents, were heavily damped by using four special waveguide ports and broadband microwave loads. Two cavities of this design were installed in the 1.54 GeV accelerator test facility (ATF) damping ring at KEK, and successfully stored beams. This cavity will also be very useful for synchrotron light sources. The basic design, characteristics of HOMs and construction of this cavity are reported.

  15. 17 GHz photonic band gap cavity with improved input coupling

    Directory of Open Access Journals (Sweden)

    M. A. Shapiro

    2001-04-01

    Full Text Available We present the theoretical design and cold test of a 17 GHz photonic band gap (PBG cavity with improved coupling from an external rectangular waveguide. The PBG cavity is made of a triangular lattice of metal rods with a defect (missing rod in the center. The TM_{010}-like defect mode was chosen as the operating mode. Experimental results are presented demonstrating that critical coupling into the cavity can be achieved by partial withdrawal or removal of some rods from the lattice, a result that agrees with simulations. A detailed design of the PBG accelerator structure is compared with a conventional (pillbox cavity. One advantage of the PBG cavity is that its resonance frequency is much less perturbed by the input/output coupling structure than in a comparable pillbox cavity. The PBG structure is attractive for future accelerator applications.

  16. Quantum noise interference and backaction cooling in cavity nanomechanics.

    Science.gov (United States)

    Elste, Florian; Girvin, S M; Clerk, A A

    2009-05-22

    We present a theoretical analysis of a novel cavity electromechanical system where a mechanical resonator directly modulates the damping rate kappa of a driven electromagnetic cavity. We show that via a destructive interference of quantum noise, the driven cavity can effectively act like a zero-temperature bath irrespective of the ratio kappa/omega_{M}, where omega_{M} is the mechanical frequency. This scheme thus allows one to cool the mechanical resonator to its ground state without requiring the cavity to be in the so-called good cavity limit kappa < omega_{M}. The system described here could be implemented directly using setups similar to those used in recent experiments in cavity electromechanics.

  17. RF kicker cavity to increase control in common transport lines

    Energy Technology Data Exchange (ETDEWEB)

    Douglas, David R.; Ament, Lucas J. P.

    2017-04-18

    A method of controlling e-beam transport where electron bunches with different characteristics travel through the same beam pipe. An RF kicker cavity is added at the beginning of the common transport pipe or at various locations along the common transport path to achieve independent control of different bunch types. RF energy is applied by the kicker cavity kicks some portion of the electron bunches, separating the bunches in phase space to allow independent control via optics, or separating bunches into different beam pipes. The RF kicker cavity is operated at a specific frequency to enable kicking of different types of bunches in different directions. The phase of the cavity is set such that the selected type of bunch passes through the cavity when the RF field is at a node, leaving that type of bunch unaffected. Beam optics may be added downstream of the kicker cavity to cause a further separation in phase space.

  18. 201 MHz Cavity R and D for MUCOOL and MICE

    International Nuclear Information System (INIS)

    Li, Derun; Virostek, Steve; Zisman, Michael; Norem, Jim; Bross, Alan; Moretti, Alfred; Norris, Barry; Torun, Yagmur; Phillips, Larry; Rimmer, Robert; Stirbet, Mircea; Reep, Michael; Summers, Don

    2006-01-01

    We describe the design, fabrication, analysis and preliminary testing of the prototype 201 MHz copper cavity for a muon ionization cooling channel. Cavity applications include the Muon Ionization Cooling Experiment (MICE) as well as cooling channels for a neutrino factory or a muon collider. This cavity was developed by the US muon cooling (MUCOOL) collaboration and is being tested in the MUCOOL Test Area (MTA) at Fermilab. To achieve a high accelerating gradient, the cavity beam irises are terminated by a pair of curved, thin beryllium windows. Several fabrication methods developed for the cavity and windows are novel and offer significant cost savings as compared to conventional construction methods. The cavity's thermal and structural performances are simulated with an FEA model. Preliminary high power RF commissioning results will be presented

  19. Driven-Dissipative Supersolid in a Ring Cavity

    Science.gov (United States)

    Mivehvar, Farokh; Ostermann, Stefan; Piazza, Francesco; Ritsch, Helmut

    2018-03-01

    Supersolids are characterized by the counterintuitive coexistence of superfluid and crystalline order. Here we study a supersolid phase emerging in the steady state of a driven-dissipative system. We consider a transversely pumped Bose-Einstein condensate trapped along the axis of a ring cavity and coherently coupled to a pair of degenerate counterpropagating cavity modes. Above a threshold pump strength the interference of photons scattered into the two cavity modes results in an emergent superradiant lattice, which spontaneously breaks the continuous translational symmetry towards a periodic atomic pattern. The crystalline steady state inherits the superfluidity of the Bose-Einstein condensate, thus exhibiting genuine properties of a supersolid. A gapless collective Goldstone mode correspondingly appears in the superradiant phase, which can be nondestructively monitored via the relative phase of the two cavity modes on the cavity output. Despite cavity-photon losses the Goldstone mode remains undamped, indicating the robustness of the supersolid phase.

  20. Cavity Quantum Electrodynamics of Continuously Monitored Bose-Condensed Atoms

    Directory of Open Access Journals (Sweden)

    Mark D. Lee

    2015-09-01

    Full Text Available We study cavity quantum electrodynamics of Bose-condensed atoms that are subjected to continuous monitoring of the light leaking out of the cavity. Due to a given detection record of each stochastic realization, individual runs spontaneously break the symmetry of the spatial profile of the atom cloud and this symmetry can be restored by considering ensemble averages over many realizations. We show that the cavity optomechanical excitations of the condensate can be engineered to target specific collective modes. This is achieved by exploiting the spatial structure and symmetries of the collective modes and light fields. The cavity fields can be utilized both for strong driving of the collective modes and for their measurement. In the weak excitation limit the condensate–cavity system may be employed as a sensitive phonon detector which operates by counting photons outside the cavity that have been selectively scattered by desired phonons.

  1. M10.3.1: LHC crab cavity specifications completed

    CERN Document Server

    Ciapala, E

    2010-01-01

    • The starting point of Sub-task 1 is to determine the full LHC system requirements for the crab cavity system. This milestone concerns completion of basic specifications for the crab cavity system. This comprises the beam requirements, the cavity impedance constraints, the operating conditions and constraints, the layout and integration constraints in LHC and very importantly machine protection issues. The specifications of the cavity itself and its ancillaries follow from these system requirements and on the technology chosen for the cavity design. • The beam requirements result from the known parameters of the LHC upgrade lattice and the expected LHC beam parameters at ultimate bunch intensity. There are boundary conditions imposed by certain beam parameters such as the bunch length and intensity and by the machine layout, mainly the available beam pipe separations at the proposed cavity positions. Requirements on RF noise and stability are tight, to avoid emittance blow-up. Machine protection issues a...

  2. LHC crab cavity specifications milestone: M10.3.1

    CERN Document Server

    Calaga, R; Jensen, E; McIntosh, P; Shaposhnikova, E; Tuckmantel, J; Zimmermann, F

    2010-01-01

    The starting point of Sub-task 1 is to determine the full LHC system requirements for the crab cavity system. This milestone concerns completion of basic specifications for the crab cavity system. This comprises the beam requirements, the cavity impedance constraints, the operating conditions and constraints, the layout and integration constraints in LHC and very importantly machine protection issues. The specifications of the cavity itself and its ancillaries follow from these system requirements and on the technology chosen for the cavity design. The beam requirements result from the known parameters of the LHC upgrade lattice and the expected LHC beam parameters at ultimate bunch intensity. There are boundary conditions imposed by certain beam parameters such as the bunch length and intensity and by the machine layout, mainly the available beam pipe separations at the proposed cavity positions. Requirements on RF noise and stability are tight, to avoid emittance blow-up. Machine protection issues arise fro...

  3. A database for superconducting cavities for the TESLA Test Facility

    International Nuclear Information System (INIS)

    Gall, P.D.; Goessel, A.; Gubarev, V.; Iversen, J.

    2006-01-01

    We look back on 10 years experience using a database for superconducting cavities for the TESLA Test Facility (TTF). The database was developed to collect data of every preparation step and measurement in order to optimize cavity production and preparation techniques to meet the ambitious goal of high accelerating gradients at high quality factors. Data from 110 superconducting 9-cell cavities, 50 single cell cavities, several 2- to 7-cell cavities and about 60 RF couplers were collected in the database. In addition, company measurements on sub-assemblies and parts forming the next 30 9-cell cavities were stored, thus establishing the database as part of a quality management system. This database is dynamically accessible via an extensive graphical web-interface based on ORACLE products, which enables the users to select and analyse the collected data easily from anywhere

  4. First Test Results of the 4-ROD Crab Cavity

    CERN Document Server

    Ambattu, P; Burt, G; Calaga, R; Capatina, O; Calatroni, S; Ciapala, E; Doherty, D; Ferreira, L; Jensen, E; Hall, B; Lingwood, C; Maesen, P; Mongelluzzo, A; Renaglia, T; Therasse, M

    2013-01-01

    The first compact prototype crab cavity with the 4rod geometry has undergone surface treatment and cold testing. Due to the complex geometry and unique fabrication procedure, RF validation of the field at beyond the nominal operating voltage at a sufficiently high Q0 is an important pre-requisite. Preliminary results of the first cold tests are presented along with cavity performance at different stages of the cavity processing is described.

  5. Cavity enhanced immunoassay measurements in microtiter plates using BBCEAS

    OpenAIRE

    Bajuszova, Z; Ali, Z; Scott, SM; Seetohul, LN; Islam, M

    2016-01-01

    We report on the first detailed use of broadband cavity enhanced absorption spectroscopy (BBCEAS) as a detection system for immunoassay. A vertical R ≥ 0.99 optical cavity was integrated with a motorised XY stage, which functioned as a receptacle for 96 well microtiter plates. The custom built cavity enhanced microplate reader was used to make measurements on a commercially available osteocalcin sandwich ELISA kit. A 30 fold increase in path length was obtained with a minimum detectable chang...

  6. Ultimate Gradient Limitation in Niobium Superconducting Accelerating Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Checchin, Mattia [Illinois Inst. of Technology, Chicago, IL (United States); Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Grassellino, Anna [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Martinello, Martina [Illinois Inst. of Technology, Chicago, IL (United States); Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Posen, Sam [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Romanenko, Alexander [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Zasadzinski, John [Illinois Inst. of Technology, Chicago, IL (United States)

    2016-06-01

    The present study is addressed to the theoretical description of the ultimate gradient limitation in SRF cavities. Our intent is to exploit experimental data to confirm models which provide feed-backs on how to improve the current state-of-art. New theoretical insight on the cavities limiting factor can be suitable to improve the quench field of N-doped cavities, and therefore to take advantage of high Q0 at high gradients.

  7. Prototype 350 MHz niobium spoke-loaded cavities

    International Nuclear Information System (INIS)

    Delayen, J. R.; Kedzie, M.; Mammosser, J.; Piller, C.; Shepard, K. W.

    1999-01-01

    This paper reports the development of 350 MHz superconducting cavities of a spoke-loaded geometry, intended for the velocity range 0.2 < v/c < 0.6. Two prototype single-cell cavities have been designed, one optimized for velocity v/c = 0.4, and the other for v/c = 0.29. Construction of the prototype niobium cavities is nearly complete. Details of the design and construction are discussed, along with the results of cold tests

  8. Prototype 350 MHz niobium spoke-loaded cavities.

    Energy Technology Data Exchange (ETDEWEB)

    Delayen, J. R.; Kedzie, M.; Mammosser, J.; Piller, C.; Shepard, K. W.

    1999-05-10

    This paper reports the development of 350 MHz superconducting cavities of a spoke-loaded geometry, intended for the velocity range 0.2 < v/c < 0.6. Two prototype single-cell cavities have been designed, one optimized for velocity v/c = 0.4, and the other for v/c = 0.29. Construction of the prototype niobium cavities is nearly complete. Details of the design and construction are discussed, along with the results of cold tests.

  9. Hydrodynamic modeling of semi-planing hulls with air cavities

    Directory of Open Access Journals (Sweden)

    Konstantin I. Matveev

    2015-05-01

    Full Text Available High-speed heavy loaded monohull ships can benefit from application of drag-reducing air cavities under stepped hull bottoms. The subject of this paper is the steady hydrodynamic modeling of semi-planing air-cavity hulls. The current method is based on a linearized potential-flow theory for surface flows. The mathematical model description and parametric calculation results for a selected configuration with pressurized and open air cavities are presented.

  10. Trains of electron pulses generation using multi-stage cavities

    International Nuclear Information System (INIS)

    Kamada, Masaki; Mori, Michiya; Sugawara, Kazuyoshi; Yamada, Yoko; Kurihara, Kazuteru; Shirasaka, Haruki; Nishiguchi, Takashi; Ando, Ritoku; Kamada, Keiichi

    2002-01-01

    Automodulation of an intense relativistic electron beam was reexamined experimentally to obtain trains of subnanosecond electron bunches. Sufficient beam modulation with frequency larger than 1 GHz was expected for the trains of subnanosecond bunches. It was obtained when a short pulse electron beam with energy of 550 keV, current of 4 kA, pulse duration of 12 ns and current rise time of 2ns was injected to a series of four coaxial cavities with the length of 75 mm. However, only a poor modulation was observed when a long pulse electron beam of 700 keV, 4 kA, 175 ns with current rise time of 20 ns was injected to the same cavities. Transmission line theory as well PIC code simulation suggested that the round trip time for the electromagnetic wave in the cavity must be longer than the rise time of the beam current to obtain the high level current modulation. Therefore, we studied experimentally how the ratio between the beam current rise time and the length of the cavity affects on the level of current modulation. Single cavity experiments were carried out with the short pulse beam. Single cavity with the length of 75, 150 or 300 mm was utilized. The round trip times for 75 and 150 mm cavities are shorter than the current rise time of 2 ns. The experiments with a 75 or 150 mm cavity resulted in suppression of the modulation amplitude. In the case of a 300 mm cavity, the high level modulation was obtained. The simulation results showed good agreements with the experimental results. We employed a series of cavities with decreasing lengths to improve the current rise time. For the short pulse beam, the high level current 1 GHz modulation was obtained when two 75 mm cavities were set at the downstream side of cavities with lengths of 300 mm and 150 mm. (author)

  11. Superconducting spoke cavities for high-velocity applications

    Energy Technology Data Exchange (ETDEWEB)

    Hopper, Christopher S. [Old Dominion U.; Delayen, Jean R. [Old Dominion U., JLAB

    2013-10-01

    To date, superconducting spoke cavities have been designed, developed, and tested for particle velocities up to {beta}{sub 0}~0.6, but there is a growing interest in possible applications of multispoke cavities for high-velocity applications. We have explored the design parameter space for low-frequency, high-velocity, double-spoke superconducting cavities in order to determine how each design parameter affects the electromagnetic properties, in particular the surface electromagnetic fields and the shunt impedance. We present detailed design for cavities operating at 325 and 352 MHz and optimized for {beta}{sub 0}~=0.82 and 1.

  12. Physical simulations of cavity closure in a creeping material

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, H.J.; Preece, D.S.

    1985-09-01

    The finite element method has been used extensively to predict the creep closure of underground petroleum storage cavities in rock salt. Even though the numerical modeling requires many simplifying assumptions, the predictions have generally correlated with field data from instrumented wellheads, however, the field data are rather limited. To gain an insight into the behavior of three-dimensional arrays of cavities and to obtain a larger data base for the verification of analytical simulations of creep closure, a series of six centrifuge simulation experiments were performed using a cylindrical block of modeling clay, a creeping material. Three of the simulations were conducted with single, centerline cavities, and three were conducted with a symmetric array of three cavities surrounding a central cavity. The models were subjected to body force loading using a centrifuge. For the single cavity experiments, the models were tested at accelerations of 100, 125 and 150 g's for 2 hours. For the multi-cavity experiments, the simulations were conducted at 100 g's for 3.25 hours. The results are analyzed using dimensional analyses. The analyses illustrate that the centrifuge simulations yield self-consistent simulations of the creep closure of fluid-filled cavities and that the interaction of three-dimensional cavity layouts can be investigated using this technique.

  13. Accelerator cavities as a probe of millicharged particles

    Energy Technology Data Exchange (ETDEWEB)

    Gies, H. [Heidelberg Univ. (Germany). Inst. fuer Theoretische Physik; Jaeckel, J.; Ringwald, A. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2006-08-15

    We investigate Schwinger pair production of millicharged fermions in the strong electric field of cavities used for particle accelerators. Even without a direct detection mechanism at hand, millicharged particles, if they exist, contribute to the energy loss of the cavity and thus leave an imprint on the cavity's quality factor. Already conservative estimates substantially constrain the electric charge of these hypothetical particles; the resulting bounds are competitive with the currently best laboratory bounds which arise from experiments based on polarized laser light propagating in a magnetic field. We propose an experimental setup for measuring the electric current comprised of the millicharged particles produced in the cavity. (orig.)

  14. Thermal and dynamic effects in electron beam welding cavities

    Energy Technology Data Exchange (ETDEWEB)

    Schauer, D.A.

    1977-08-01

    An experimental and analytical study of the temperature distributions along the molten metal surface in an electron beam welding cavity is described. Surface temperature distributions in cavities were measured with a narrow band infrared radiation pyrometer. The availability of the cavity temperature measurements allowed estimates to be made for the vapor pressure and surface energy forces as a function of cavity position. The results indicated a force imbalance occurred in the cavity. It is postulated that at the location of the force imbalance a liquid material projection forms periodically and moves into the path of the electron beam. The liquid in this projection is driven towards the bottom, partially filling the cavity. This action is followed by the electron beam pushing the liquid aside to form a maximum depth cavity. This process is then repeated. An analysis for predicting cavity oscillation frequency shows reasonable agreement with frequencies measured at the weld root determined from weld sections. A study of the measured temperature distributions in cavities of varying depth combined with the force imbalance observations led to an interpretation of when spiking might occur. A procedure is proposed for determining the spiking tendency for a given set of weld parameters. The results of this study permit a designer to select apriori the best set of weld parameters to achieve a weld of predictable quality.

  15. Thermal and dynamic effects in electron beam welding cavities

    International Nuclear Information System (INIS)

    Schauer, D.A.

    1977-08-01

    An experimental and analytical study of the temperature distributions along the molten metal surface in an electron beam welding cavity is described. Surface temperature distributions in cavities were measured with a narrow band infrared radiation pyrometer. The availability of the cavity temperature measurements allowed estimates to be made for the vapor pressure and surface energy forces as a function of cavity position. The results indicated a force imbalance occurred in the cavity. It is postulated that at the location of the force imbalance a liquid material projection forms periodically and moves into the path of the electron beam. The liquid in this projection is driven towards the bottom, partially filling the cavity. This action is followed by the electron beam pushing the liquid aside to form a maximum depth cavity. This process is then repeated. An analysis for predicting cavity oscillation frequency shows reasonable agreement with frequencies measured at the weld root determined from weld sections. A study of the measured temperature distributions in cavities of varying depth combined with the force imbalance observations led to an interpretation of when spiking might occur. A procedure is proposed for determining the spiking tendency for a given set of weld parameters. The results of this study permit a designer to select apriori the best set of weld parameters to achieve a weld of predictable quality

  16. Improved surface treatment of the superconducting TESLA cavities

    CERN Document Server

    Lilje, L; Benvenuti, Cristoforo; Bloess, D; Charrier, J P; Chiaveri, Enrico; Ferreira, L; Losito, R; Matheisen, A; Preis, H; Proch, D; Reschke, D; Safa, H; Schmüser, P; Trines, D; Visentin, B; Wenninger, Horst

    2004-01-01

    The proposed linear electron-positron collider TESLA is based on 1.3 GHz superconducting niobium cavities for particle acceleration. For a centre-of-mass energy of 500 GeV, an accelerating field of 23.4 MV/m is required which is reliably achieved with a niobium surface preparation by chemical etching. An upgrade of the collider to 800 GeV requires an improved cavity preparation technique. In this paper, results are presented on single-cell cavities which demonstrate that fields of up to 40 MV/m are accessible by electrolytic polishing of the inner surface of the cavity.

  17. Experimental analysis of surface finish in normal conducting cavities

    Science.gov (United States)

    Zarrebini-Esfahani, A.; Aslaninejad, M.; Ristic, M.; Long, K.

    2017-10-01

    A normal conducting 805 MHz test cavity with an in built button shaped sample is used to conduct a series of surface treatment experiments. The button enhances the local fields and influences the likelihood of an RF breakdown event. Because of their smaller sizes, compared to the whole cavity surface, they allow practical investigations of the effects of cavity surface preparation in relation to RF breakdown. Manufacturing techniques and steps for preparing the buttons to improve the surface quality are described in detail. It was observed that even after the final stage of the surface treatment, defects on the surface of the cavities still could be found.

  18. Investigation on computation of elliptical microwave plasma cavity

    Science.gov (United States)

    Liao, Xiaoli; Liu, Hua; Zhang, Kai

    2008-12-01

    In recent years, the advance of the elliptical resonant cavity and focus cavity is known by many people. There are homogeneous and multipatternal virtues in the focus dimensional microwave field of the elliptical resonant cavity. It is very suitable for applying the low power microwave biological effect equipment. However, when designing the elliptical resonant cavity may meet the problems of complex and huge computation need to be solved. This paper proposed the simple way of approximate processing the Mathieu function. It can greatly simplify the difficulty and decrease the scale of computation. This method can satisfy the requirements of research and development within project permitted precision.

  19. Fabrication process for the PEP II RF cavities

    Energy Technology Data Exchange (ETDEWEB)

    Franks, R.M.; Rimmer, R.A. [Lawrence Berkeley National Lab., CA (United States); Schwarz, H. [Stanford Linear Accelerator Center, Menlo Park, CA (United States)

    1997-06-05

    This paper presents the major steps used in the fabrication of the 26 RF Cavities required for the PEP-II B-factory. Several unique applications of conventional processes have been developed and successfully implemented: electron beam welding (EBW), with minimal porosity, of .75 inch (19 mm) copper cross-sections; extensive 5-axis milling of water channels; electroplating of .37 inch (10 mm) thick OFE copper; tuning of the cavity by profiling beam noses prior to final joining with the cavity body; and machining of the cavity interior, are described here.

  20. Multipactor in crossed rf fields on the cavity equator

    Directory of Open Access Journals (Sweden)

    Valery Shemelin

    2013-01-01

    Full Text Available Multipactor discharge in an accelerating superconducting elliptic cavity occurs usually near its equator. As simulations show, the dimensions of the trajectories of multipacting electrons are very small compared to the dimensions of a cavity. This feature gives a way for solving explicit equations of motion instead of cumbersome simulations. Electric and magnetic fields near the cavity equator are presented in a form of expansions up to the third power of coordinates. Comparisons with numerical calculations of fields made with the SLANS code for the TESLA cavity cells, as well as with the analytical solution for a spherical cavity, are done. These fields are used for solving the equations of motion of electrons in crossed rf fields near the equator. Based on the analysis of these equations, general features of multipacting in this area are obtained. Results are compared with simulations and experimental data. The experimental formulas for multipacting zones are explained and their dependence on the cavity geometries is shown. Because of small sizes of electron trajectories, the influence of the weld seams is taken into account. This suggests a possible explanation of multipacting in a cavity which was not found by simulations. The developed approach allows evaluation of multipacting in a cavity without its simulations but after an analysis of fields in the equatorial region. These fields can be computed by any code used for cavity calculation.

  1. Internalization of Calcium Oxalate Calculi Developed in Narrow Cavities

    Directory of Open Access Journals (Sweden)

    Fèlix Grases

    2014-03-01

    Full Text Available We describe the case of a patient with calcium oxalate monohydrate and calcium oxalate dihydrate calculi occluded in cavities. All those calculi were located inside narrow cavities covered with a thin epithelium that permits their visualization. Urinary biochemical analysis showed high calciuria, not hypercalciuria, hypocitraturia, and a ratio [calcium]/[citrate] >0.33. The existence of cavities of very low urodynamic efficacy was decisive in the formation of such calculi. It is important to emphasize that we observed a thin epithelium covering such cavities, demonstrating that this epithelium may be formed after the development of the calculi through a re-epithelialization process.

  2. Cavity characterization for general use in linear electron accelerators

    International Nuclear Information System (INIS)

    Souza Neto, M.V. de.

    1985-01-01

    The main objective of this work is to is to develop measurement techniques for the characterization of microwave cavities used in linear electron accelerators. Methods are developed for the measurement of parameters that are essential to the design of an accelerator structure using conventional techniques of resonant cavities at low power. Disk-loaded cavities were designed and built, similar to those in most existing linear electron accelerators. As a result, the methods developed and the estimated accuracy were compared with those from other investigators. The results of this work are relevant for the design of cavities with the objective of developing linear electron accelerators. (author) [pt

  3. A novel nano-sensor based on optomechanical crystal cavity

    Science.gov (United States)

    Zhang, Yeping; Ai, Jie; Ma, Jingfang

    2017-10-01

    Optical devices based on new sensing principle are widely used in biochemical and medical area. Nowadays, mass sensing based on monitoring the frequency shifts induced by added mass in oscillators is a well-known and widely used technique. It is interesting to note that for nanoscience and nanotechnology applications there is a strong demand for very sensitive mass sensors, being the target a sensor for single molecule detection. The desired mass resolution for very few or even single molecule detection, has to be below the femtogram range. Considering the strong interaction between high co-localized optical mode and mechanical mode in optomechanical crystal (OMC) cavities, we investigate OMC splitnanobeam cavities in silicon operating near at the 1550nm to achieve high optomechanical coupling rate and ultra-small motion mass. Theoretical investigations of the optical and mechanical characteristic for the proposed cavity are carried out. By adjusting the structural parameters, the cavity's effective motion mass below 10fg and mechanical frequency exceed 10GHz. The transmission spectrum of the cavity is sensitive to the sample which located on the center of the cavity. We conducted the fabrication and the characterization of this cavity sensor on the silicon-on-insulator (SOI) chip. By using vertical coupling between the tapered fiber and the SOI chip, we measured the transmission spectrum of the cavity, and verify this cavity is promising for ultimate precision mass sensing and detection.

  4. Nylon Sleeve for Cavity Amplifier Holds Tuning Despite Heat

    Science.gov (United States)

    Derr, Lloyd

    1964-01-01

    The problem: Detuning of cavity amplifiers with change in temperature. This results in deterioration of the performance of the amplifier at its design frequency. In cavity amplifiers and filters it is desirable that constant performance be maintained regardless of thermal changes. These changes often cause an "off resonance shift" in a cavity filter and a deterioration of performance in a cavity amplifier. The solution: Mount the tuning probe in a nylon sleeve. Thermal expansion and contraction of the nylon nullifies unwanted capacitive and inductive changes in the resonant elements.

  5. Cerebellar cortical infarct cavities and vertebral artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Cocker, Laurens J.L. de [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Kliniek Sint-Jan Radiologie, Brussels (Belgium); Compter, A.; Kappelle, L.J.; Worp, H.B. van der [University Medical Center Utrecht, Department of Neurology and Neurosurgery, Brain Center Rudolf Magnus, Utrecht (Netherlands); Luijten, P.R.; Hendrikse, J. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands)

    2016-09-15

    Cerebellar cortical infarct cavities are a newly recognised entity associated with atherothromboembolic cerebrovascular disease and worse physical functioning. We aimed to investigate the relationship of cerebellar cortical infarct cavities with symptomatic vertebrobasilar ischaemia and with vascular risk factors. We evaluated the MR images of 46 patients with a recent vertebrobasilar TIA or stroke and a symptomatic vertebral artery stenosis ≥50 % from the Vertebral Artery Stenting Trial (VAST) for the presence of cerebellar cortical infarct cavities ≤1.5 cm. At inclusion in VAST, data were obtained on age, sex, history of vertebrobasilar TIA or stroke, and vascular risk factors. Adjusted risk ratios were calculated with Poisson regression analyses for the relation between cerebellar cortical infarct cavities and vascular risk factors. Sixteen out of 46 (35 %) patients showed cerebellar cortical infarct cavities on the initial MRI, and only one of these 16 patients was known with a previous vertebrobasilar TIA or stroke. In patients with symptomatic vertebrobasilar ischaemia, risk factor profiles of patients with cerebellar cortical infarct cavities were not different from patients without these cavities. Cerebellar cortical infarct cavities are seen on MRI in as much as one third of patients with recently symptomatic vertebral artery stenosis. Since patients usually have no prior history of vertebrobasilar TIA or stroke, cerebellar cortical infarct cavities should be added to the spectrum of common incidental brain infarcts visible on routine MRI. (orig.)

  6. Ring cavity for a Raman capillary waveguide amplifier

    Science.gov (United States)

    Kurnit, N.A.

    1981-01-27

    A regenerative ring amplifier and regenerative ring oscillator are described which function to feed back a portion of the Stokes signal to complete the ring cavity. The ring cavity configuration allows the CO/sub 2/ laser pump signal and Stokes signal to copropagate through the Raman capillary waveguide amplifier. A Raman capillary waveguide amplifier is also provided in the return leg of the ring cavity to increase gain without increasing the round trip time. Additionally, the ring cavity can be designed such that the amplified Stokes signal is synchronous with the mode-locked spikes of the incoming CO/sub 2/ laser pump signal.

  7. Ring cavity for a Raman capillary waveguide amplifir

    Science.gov (United States)

    Kurnit, N.A.

    1981-01-27

    A regenerative ring amplifier and regenerative ring oscillator are described which function to feed back a portion of the Stokes signal to complete the ring cavity. The ring cavity configuration allows the CO/sub 2/ laser pump signal and Stokes signal to copropagate through the Raman capillary waveguide amplifier. A Raman capillary waveguide amplifier is also provided in the return leg of the ring cavity to increase gain without increasing the round trip time. Additionally, the ring cavity can be designed such that the amplified Stokes signal is synchronous with the mode-locked spikes of the incoming CO/sub 2/ laser pump signal.

  8. Tunable cavity resonator including a plurality of MEMS beams

    Science.gov (United States)

    Peroulis, Dimitrios; Fruehling, Adam; Small, Joshua Azariah; Liu, Xiaoguang; Irshad, Wasim; Arif, Muhammad Shoaib

    2015-10-20

    A tunable cavity resonator includes a substrate, a cap structure, and a tuning assembly. The cap structure extends from the substrate, and at least one of the substrate and the cap structure defines a resonator cavity. The tuning assembly is positioned at least partially within the resonator cavity. The tuning assembly includes a plurality of fixed-fixed MEMS beams configured for controllable movement relative to the substrate between an activated position and a deactivated position in order to tune a resonant frequency of the tunable cavity resonator.

  9. HOM frequency control of SRF cavity in high current ERLs

    Science.gov (United States)

    Xu, Chen; Ben-Zvi, Ilan

    2018-03-01

    The acceleration of high-current beam in Superconducting Radio Frequency (SRF) cavities is a challenging but essential for a variety of advanced accelerators. SRF cavities should be carefully designed to minimize the High Order Modes (HOM) power generated in the cavities by the beam current. The reduction of HOM power we demonstrate in a particular case can be quite large. This paper presents a method to systematically control the HOM resonance frequencies in the initial design phase to minimize the HOM power generation. This method is expected to be beneficial for the design of high SRF cavities addressing a variety of Energy Recovery Linac (ERL) applications.

  10. Demonstration of an optical enhancement cavity with 10 micron wavelength

    Science.gov (United States)

    Sakaue, K.; Washio, M.; Endo, A.

    2015-05-01

    We have been developing a pulsed-laser optical enhancement cavity for laser-Compton scattering (LCS). LCS can produce high brightness X-ray through the collision between relativistic electrons generated from the accelerator and high power laser photons with a compact facility. In order to increase the number of collisions/sec, high repetition rate accelerator and laser are required. For the laser system, an optical enhancement cavity is the most powerful tool for LCS, thus we have been developing the cavity for storing 1 micron laser pulse. On the other hand, the resulting X-ray energy can be changed by the collision laser wavelength. If we have another optical cavity with different wavelength, the multicolor, quasi-monochromatic, high brightness and compact X-ray source can be realized. Therefore, we started to develop an optical cavity at 10 micron wavelength with CO2 laser. At this wavelength region, the absorption loss is dominant compared with scattering loss. Thus we carefully chose the optical mirrors for enhancement cavity. We demonstrated a more than 200 enhancement factor with 795 finesse optical cavity at 10 micron CO2 laser. Moreover, 2.3 kW storage in the optical cavity was successfully demonstrated. The design of optical cavity, first experimental results and future prospects will be presented at the conference.

  11. Perfect routing of quantum information in regular cavity QED networks

    Science.gov (United States)

    Behzadi, Naghi; Rudsary, Sobhan Kazemi; Salmasi, Bahram Ahansaz

    2013-12-01

    We introduce a scheme for perfect routing of quantum states and entanglement in regular cavity QED networks. The couplings between the cavities are quasi-uniform and each cavity is doped with a two-level atom. Quasi-uniform couplings leads the system to evolve in invariant subspaces. Combination the evolutions of the system in its invariant subspaces with quite simple local operations on atoms in the networks, gives the perfect routing of quantum states and entanglement through the network. To provide the protocol be robust due to decoherence arisen from photon loss, the field mode of the cavities are only virtually excited.

  12. Rf drive system for the CEBAF superconducting cavities

    International Nuclear Information System (INIS)

    Fugitt, J.A.; Moore, T.L.

    1986-01-01

    To obtain the maximum accelerating gradient, the CEBAF RF system uses an individually controlled RF drive chain for each superconducting cavity. This allows one to adjust each cavity to its individual maximum field. Due to material purity and manufacturing tolerances of the cavities, it is expected that this maximum value will be distributed over an almost 2 to 1 gradient range. The requirement for precise individual phase and gradient control of 420 superconducting accelerating cavities, is accomplished through the use of individual fault tolerant RF drive chains and self monitoring control electronics. This might be thought of as the Phased Array approach to accelerator RF systems

  13. Efficacy and safety of intravenous fentanyl administered by ambulance personnel

    DEFF Research Database (Denmark)

    Friesgaard, Kristian Dahl; Nikolajsen, Lone; Giebner, Matthias

    2016-01-01

    BACKGROUND: Management of pain in the pre-hospital setting is often inadequate. In 2011, ambulance personnel were authorized to administer intravenous fentanyl in the Central Denmark Region. The aim of this study was to evaluate the efficacy and safety of intravenous fentanyl administered...... by ambulance personnel. METHODS: Pre-hospital medical charts from 2348 adults treated with intravenous fentanyl by ambulance personnel during a 6-month period were reviewed. The primary outcome was the change in pain intensity on a numeric rating scale (NRS) from before fentanyl treatment to hospital arrival....... Secondary outcomes included the number of patients with reduction in pain intensity during transport (NRS ≥ 2), the number of patients with NRS > 3 at hospital arrival, and potential fentanyl-related side effects. RESULTS: Fentanyl reduced pain from before treatment (8, IQR 7-9) to hospital arrival (4, IQR...

  14. Techniques to administer oral, inhalational, and IV sedation in dentistry

    OpenAIRE

    Diana Krystyna Harbuz; Michael O’Halloran

    2016-01-01

    Background Sedation in dentistry is a controversial topic given the variety of opinions regarding its safe practice. Aims This article evaluates the various techniques used to administer sedation in dentistry and specific methods practiced to form a recommendation for clinicians. Methods An extensive literature search was performed using PubMed, Medline, Google Scholar, Google, and local library resources. Results Most of the literature revealed a consensus that li...

  15. Challenging situations when administering palliative chemotherapy - a nursing perspective.

    Science.gov (United States)

    Näppä, Ulla; Rasmussen, Birgit H; Axelsson, Bertil; Lindqvist, Olav

    2014-12-01

    Palliative chemotherapy treatments (PCT) are becoming more common for patients with incurable cancer; a basic challenge is to optimize tumour response while minimizing side-effects and harm. As registered nurses most often administer PCT, they are most likely to be confronted with difficult situations during PCT administration. This study explores challenging situations experienced by nurses when administering PCT to patients with incurable cancer. Registered nurses experienced in administering PCT were asked in interviews to recall PCT situations they found challenging. Inspired by the narrative tradition, stories were elicited and analysed using a structural and thematic narrative analysis. A total of twenty-eight stories were narrated by seventeen nurses. Twenty of these were dilemmas that could be sorted into three storylines containing one to three dilemmatic situations each. The six dilemmatic situations broadly related to three interwoven areas: the uncertainty of the outcome when giving potent drugs to vulnerable patients; the difficulty of resisting giving PCT to patients who want it; and insufficient communication between nurses and physician. Nurses who administer PCT are engaged in a complex task that can give rise to a number of dilemmatic situations. The findings may be interpreted as meaning that at least some situations might be preventable if the knowledge and insight of all team members - nurses, physicians, patients, and relatives - are jointly communicated and taken into account when deciding whether or not to give PCT. Forming palliative care teams early in the PCT trajectory, could be beneficial for staff and patients. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Absorption sites of orally administered drugs in the small intestine.

    Science.gov (United States)

    Murakami, Teruo

    2017-12-01

    In pharmacotherapy, drugs are mostly taken orally to be absorbed systemically from the small intestine, and some drugs are known to have preferential absorption sites in the small intestine. It would therefore be valuable to know the absorption sites of orally administered drugs and the influencing factors. Areas covered:In this review, the author summarizes the reported absorption sites of orally administered drugs, as well as, influencing factors and experimental techniques. Information on the main absorption sites and influencing factors can help to develop ideal drug delivery systems and more effective pharmacotherapies. Expert opinion: Various factors including: the solubility, lipophilicity, luminal concentration, pKa value, transporter substrate specificity, transporter expression, luminal fluid pH, gastrointestinal transit time, and intestinal metabolism determine the site-dependent intestinal absorption. However, most of the dissolved fraction of orally administered drugs including substrates for ABC and SLC transporters, except for some weakly basic drugs with higher pKa values, are considered to be absorbed sequentially from the proximal small intestine. Securing the solubility and stability of drugs prior to reaching to the main absorption sites and appropriate delivery rates of drugs at absorption sites are important goals for achieving effective pharmacotherapy.

  17. Cavity-type hypersonic phononic crystals

    International Nuclear Information System (INIS)

    Sato, A; Fytas, G; Pennec, Y; Djafari-Rouhani, B; Yanagishita, T; Masuda, H; Knoll, W

    2012-01-01

    We report on the engineering of the phonon dispersion diagram in monodomain anodic porous alumina (APA) films through the porosity and physical state of the material residing in the nanopores. Lattice symmetry and inclusion materials are theoretically identified to be the main factors which control the hypersonic acoustic wave propagation. This involves the interaction between the longitudinal and the transverse modes in the effective medium and a flat band characteristic of the material residing in the cavities. Air and filled nanopores, therefore, display markedly different dispersion relations and the inclusion materials lead to a locally resonant structural behavior uniquely determining their properties under confinement. APA films emerge as a new platform to investigate the rich acoustic phenomena of structured composite matter. (paper)

  18. Compact and highly efficient laser pump cavity

    Science.gov (United States)

    Chang, Jim J.; Bass, Isaac L.; Zapata, Luis E.

    1999-01-01

    A new, compact, side-pumped laser pump cavity design which uses non-conventional optics for injection of laser-diode light into a laser pump chamber includes a plurality of elongated light concentration channels. In one embodiment, the light concentration channels are compound parabolic concentrators (CPC) which have very small exit apertures so that light will not escape from the pumping chamber and will be multiply reflected through the laser rod. This new design effectively traps the pump radiation inside the pump chamber that encloses the laser rod. It enables more uniform laser pumping and highly effective recycle of pump radiation, leading to significantly improved laser performance. This new design also effectively widens the acceptable radiation wavelength of the diodes, resulting in a more reliable laser performance with lower cost.

  19. Photon momentum and optical forces in cavities

    DEFF Research Database (Denmark)

    Partanen, Mikko; Häyrynen, Teppo; Oksanen, Jani

    2016-01-01

    During the past century, the electromagnetic field momentum in material media has been under debate in the Abraham-Minkowski controversy as convincing arguments have been advanced in favor of both the Abraham and Minkowski forms of photon momentum. Here we study the photon momentum and optical...... forces in cavity structures in the cases of dynamical and steady-state fields. In the description of the single-photon transmission process, we use a field-kinetic one-photon theory. Our model suggests that in the medium photons couple with the induced atomic dipoles forming polariton quasiparticles...... with the Minkowski form momentum. The Abraham momentum can be associated to the electromagnetic field part of the coupled polariton state. The polariton with the Minkowski momentum is shown to obey the uniform center of mass of energy motion that has previously been interpreted to support only the Abraham momentum...

  20. Long Wave Infrared Cavity Enhanced Sensors

    Energy Technology Data Exchange (ETDEWEB)

    Taubman, Matthew S.; Scott, David C.; Cannon, Bret D.; Myers, Tanya L.; Munley, John T.; Nguyen, Vinh T.; Schultz, John F.

    2005-12-01

    The principal goal of Pacific Northwest National Laboratory's (PNNL's) long wave infrared (LWIR) cavity enhanced sensor (CES) task is to explore ultra-sensitive spectroscopic chemical sensing techniques and apply them to detecting proliferation of weapons of mass destruction (WMD). Our primary application is detecting signatures of WMD production, but LWIR CES techniques are also capable of detecting chemical weapons. The LWIR CES task is concerned exclusively with developing novel point sensors; stand-off detection is addressed by other PNNL tasks and projects. PNNL's LWIR CES research is distinguished from that done by others by the use quantum cascade lasers (QCLs) as the light source. QCLs are novel devices, and a significant fraction of our research has been devoted to developing the procedures and hardware required to implement them most effectively for chemical sensing. This report details the progress we have made on LWIR CES sensor development.

  1. Miniature Cavity-Enhanced Diamond Magnetometer

    Science.gov (United States)

    Chatzidrosos, Georgios; Wickenbrock, Arne; Bougas, Lykourgos; Leefer, Nathan; Wu, Teng; Jensen, Kasper; Dumeige, Yannick; Budker, Dmitry

    2017-10-01

    We present a highly sensitive miniaturized cavity-enhanced room-temperature magnetic-field sensor based on nitrogen-vacancy centers in diamond. The magnetic resonance signal is detected by probing absorption on the 1042-nm spin-singlet transition. To improve the absorptive signal the diamond is placed in an optical resonator. The device has a magnetic-field sensitivity of 28 pT /√{Hz } , a projected photon shot-noise-limited sensitivity of 22 pT /√{Hz } , and an estimated quantum projection-noise-limited sensitivity of 0.43 pT /√{Hz } with the sensing volume of ˜390 μ m ×4500 μ m2 . The presented miniaturized device is the basis for an endoscopic magnetic-field sensor for biomedical applications.

  2. Climate Modeling: Ocean Cavities below Ice Shelves

    Energy Technology Data Exchange (ETDEWEB)

    Petersen, Mark Roger [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Computer, Computational, and Statistical Sciences Division

    2016-09-12

    The Accelerated Climate Model for Energy (ACME), a new initiative by the U.S. Department of Energy, includes unstructured-mesh ocean, land-ice, and sea-ice components using the Model for Prediction Across Scales (MPAS) framework. The ability to run coupled high-resolution global simulations efficiently on large, high-performance computers is a priority for ACME. Sub-ice shelf ocean cavities are a significant new capability in ACME, and will be used to better understand how changing ocean temperature and currents influence glacial melting and retreat. These simulations take advantage of the horizontal variable-resolution mesh and adaptive vertical coordinate in MPAS-Ocean, in order to place high resolution below ice shelves and near grounding lines.

  3. Squamous cell carcinoma of the oral cavity

    International Nuclear Information System (INIS)

    Lindeloev, B.; Kirkegaard, J.; Hansen, H.S.; Copenhagen Univ. Hospital

    1990-01-01

    Three hundred and four patients with squamous cell carcinomas of the oral cavity were treated at the Finsen Institute in cooperation with the ENT-surgical departments between 1978 and 1982. The primary treatment consisted of radiotherapy alone in 74%, surgery alone in 4%, and a combination of radiotherapy and surgery in 15% of the patients. 2% received other treatment (cryotherapy), 5% did not complete the planned radiotherapy, and 1% were not treated at all. Of 203 patients with tumour remnant or first recurrence, 45% were operated, 2% received radiotherapy, and 2% combined treatment. This treatment strategy made 38% of the patients free of disease in the follow-up period (3 1/2 to 8 years) or until the patients died from other causes. Fifty-nine percent of the patients died from their oral carcinomas. Tumour size (T), lymph node status (N), and tumour stage were as expected important prognostic factors. (orig.)

  4. Quantum quincunx in cavity quantum electrodynamics

    International Nuclear Information System (INIS)

    Sanders, Barry C.; Bartlett, Stephen D.; Tregenna, Ben; Knight, Peter L.

    2003-01-01

    We introduce the quantum quincunx, which physically demonstrates the quantum walk and is analogous to Galton's quincunx for demonstrating the random walk by employing gravity to draw pellets through pegs on a board, thereby yielding a binomial distribution of final peg locations. In contradistinction to the theoretical studies of quantum walks over orthogonal lattice states, we introduce quantum walks over nonorthogonal lattice states (specifically, coherent states on a circle) to demonstrate that the key features of a quantum walk are observable albeit for strict parameter ranges. A quantum quincunx may be realized with current cavity quantum electrodynamics capabilities, and precise control over decoherence in such experiments allows a remarkable decrease in the position noise, or spread, with increasing decoherence

  5. The splitring loaded RF-cavity

    Science.gov (United States)

    Müller, Eckhard; Klein, Horst

    1984-07-01

    Experimental and theoretical work was done on the splitring loaded resonant rf-cavity. Formulae are derived for the determination of the resonance frequencies, Rp-value and shunt impedance dependent on the resonator geometry. The calculations were verified by experiments carried out by the authors as well as by measurements reported in literature. The theoretical and experimental optimizations were incorporated in a construction of a normal-conducting section laid out for a resonance frequency of 108 MHz, a particle velocity corresponding to β = v/ c = 0.057 and with an Rp-value of 14.5 MΩ producing an acceleration voltage of 1 MV. This resonator is part of a small postaccelerator, installed at the Frankfurt single-ended 7 MV CN Van de Graaff generator and has been tested with a particle beam.

  6. Electronic cigarette explosions involving the oral cavity.

    Science.gov (United States)

    Harrison, Rebecca; Hicklin, David

    2016-11-01

    The use of electronic cigarettes (e-cigarettes) is a rapidly growing trend throughout the United States. E-cigarettes have been linked to the risk of causing explosion and fire. Data are limited on the associated health hazards of e-cigarette use, particularly long-term effects, and available information often presents conflicting conclusions. In addition, an e-cigarette explosion and fire can pose a unique treatment challenge to the dental care provider because the oral cavity may be affected heavily. In this particular case, the patient's injuries included intraoral burns, luxation injuries, and alveolar fractures. This case report aims to help clinicians gain an increased knowledge about e-cigarette design, use, and risks; discuss the risk of spontaneous failure and explosion of e-cigarettes with patients; and understand the treatment challenges posed by an e-cigarette explosion. Copyright © 2016 American Dental Association. Published by Elsevier Inc. All rights reserved.

  7. Air riding seal with purge cavity

    Science.gov (United States)

    Sexton, Thomas D; Mills, Jacob A

    2017-08-15

    An air riding seal for a turbine in a gas turbine engine, where an annular piston is axial moveable within an annular piston chamber formed in a stator of the turbine and forms a seal with a surface on the rotor using pressurized air that forms a cushion in a pocket of the annular piston. A purge cavity is formed on the annular piston and is connected to a purge hole that extends through the annular piston to a lower pressure region around the annular piston or through the rotor to an opposite side. The annular piston is sealed also with inner and outer seals that can be a labyrinth seal to form an additional seal than the cushion of air in the pocket to prevent the face of the air riding seal from overheating.

  8. Cavity Microwave Searches for Cosmological Axions

    CERN Multimedia

    CERN. Geneva

    2005-01-01

    The lecture will cover the searches for dark matter axions based on the microwave cavity experiment of Sikivie. The topics will begin with a brief overview of halo dark matter, and the axion as a candidate. The principle of resonant conversion of axions in an external magnetic field will be described, and practical considerations in optimizing the experiment as a signal-to-noise problem. A major focus of the lecture will be the two complementary strategies for ultra-low noise detection of the microwave photons - the "photon-as-wave" approach (i.e. conventional heterojunction amplifiers and soon quantum-limited SQUID devices), and "photon-as-particle" (i.e. Rydberg-atom single-quantum detection). Experimental results will be presented; these experiments have already reached well into the range of sensitivity to exclude plausible axion models, for limited ranges of mass. The lecture will conclude with a discussion of future plans and challenges for the microwave ca...

  9. Cavity optomechanics in gallium phosphide microdisks

    International Nuclear Information System (INIS)

    Mitchell, Matthew; Barclay, Paul E.; Hryciw, Aaron C.

    2014-01-01

    We demonstrate gallium phosphide (GaP) microdisk optical cavities with intrinsic quality factors >2.8 × 10 5 and mode volumes 3 , and study their nonlinear and optomechanical properties. For optical intensities up to 8.0 × 10 4 intracavity photons, we observe optical loss in the microcavity to decrease with increasing intensity, indicating that saturable absorption sites are present in the GaP material, and that two-photon absorption is not significant. We observe optomechanical coupling between optical modes of the microdisk around 1.5 μm and several mechanical resonances, and measure an optical spring effect consistent with a theoretically predicted optomechanical coupling rate g 0 /2π∼30 kHz for the fundamental mechanical radial breathing mode at 488 MHz

  10. Three-Dimensional Morphology of a Coronal Prominence Cavity

    Science.gov (United States)

    Gibson, S. E.; Kucera, T. A.; Rastawicki, D.; Dove, J.; deToma, G.; Hao, J.; Hill, S.; Hudson, H. S.; Marque, C.; McIntosh, P. S.; hide

    2010-01-01

    We present a three-dimensional density model of coronal prominence cavities, and a morphological fit that has been tightly constrained by a uniquely well-observed cavity. Observations were obtained as part of an International Heliophysical Year campaign by instruments from a variety of space- and ground-based observatories, spanning wavelengths from radio to soft-X-ray to integrated white light. From these data it is clear that the prominence cavity is the limb manifestation of a longitudinally-extended polar-crown filament channel, and that the cavity is a region of low density relative to the surrounding corona. As a first step towards quantifying density and temperature from campaign spectroscopic data, we establish the three-dimensional morphology of the cavity. This is critical for taking line-of-sight projection effects into account, since cavities are not localized in the plane of the sky and the corona is optically thin. We have augmented a global coronal streamer model to include a tunnel-like cavity with elliptical cross-section and a Gaussian variation of height along the tunnel length. We have developed a semi-automated routine that fits ellipses to cross-sections of the cavity as it rotates past the solar limb, and have applied it to Extreme Ultraviolet Imager (EUVI) observations from the two Solar Terrestrial Relations Observatory (STEREO) spacecraft. This defines the morphological parameters of our model, from which we reproduce forward-modeled cavity observables. We find that cavity morphology and orientation, in combination with the viewpoints of the observing spacecraft, explains the observed variation in cavity visibility for the east vs. west limbs

  11. Isolation of intact sub-dermal secretory cavities from Eucalyptus

    Directory of Open Access Journals (Sweden)

    Goodger Jason QD

    2010-09-01

    Full Text Available Abstract Background The biosynthesis of plant natural products in sub-dermal secretory cavities is poorly understood at the molecular level, largely due to the difficulty of physically isolating these structures for study. Our aim was to develop a protocol for isolating live and intact sub-dermal secretory cavities, and to do this, we used leaves from three species of Eucalyptus with cavities that are relatively large and rich in essential oils. Results Leaves were digested using a variety of commercially available enzymes. A pectinase from Aspergillus niger was found to allow isolation of intact cavities after a relatively short incubation (12 h, with no visible artifacts from digestion and no loss of cellular integrity or cavity contents. Several measurements indicated the potential of the isolated cavities for further functional studies. First, the cavities were found to consume oxygen at a rate that is comparable to that estimated from leaf respiratory rates. Second, mRNA was extracted from cavities, and it was used to amplify a cDNA fragment with high similarity to that of a monoterpene synthase. Third, the contents of the cavity lumen were extracted, showing an unexpectedly low abundance of volatile essential oils and a sizeable amount of non-volatile material, which is contrary to the widely accepted role of secretory cavities as predominantly essential oil repositories. Conclusions The protocol described herein is likely to be adaptable to a range of Eucalyptus species with sub-dermal secretory cavities, and should find wide application in studies of the developmental and functional biology of these structures, and the biosynthesis of the plant natural products they contain.

  12. Commensal communism and the oral cavity.

    Science.gov (United States)

    Henderson, B; Wilson, M

    1998-09-01

    The world we live in contains unimaginable numbers of bacteria, and these and other single-celled creatures represent the major diversity of life on our planet. During the last decade or so, the complexity and intimacy of the interactions which occur between bacteria and host eukaryotic cells during the process of infection have begun to emerge. The study of such interactions is the subject of the new discipline of cellular microbiology. This intimacy of bacteria/host interactions creates a major paradox. The average human being is 90% bacteria in terms of cell numbers. These bacteria constitute the commensal or normal microflora and populate the mucosal surfaces of the oral cavity, gastrointestinal tract, urogenital tract, and the surface of the skin. In bacterial infections, much of the pathology is due to the release of a range of bacterial components (e.g., modulins such as lipopolysaccharide, peptidoglycan, DNA, molecular chaperones), which induce the synthesis of the local hormone-like molecules known as pro-inflammatory cytokines. However, such components must also be constantly released by the vast numbers of bacteria constituting the normal microflora and, as a consequence, our mucosae should constantly be in a state of inflammation. This is patently not the case, and a hypothesis is forwarded to account for this "commensal paradox", namely, that our commensal bacteria and mucosal surfaces exist in a state of bio-communism, forming a unified "tissue" in which interactions between bacteria and epithelia are finely balanced to ensure bacterial survival and prevent the induction of damaging inflammation. Evidence is emerging that bacteria can produce a variety of proteins which can inhibit the synthesis/release of inflammatory cytokines. The authors predict that such proteins are simply one part of an extensive signaling system which occurs between bacteria and epithelial cells at mucosal surfaces such as those found in the oral cavity.

  13. Dynamic resonance of light in Fabry-Perot cavities

    International Nuclear Information System (INIS)

    Rakhmanov, M.; Savage, R.L.; Reitze, D.H.; Tanner, D.B.

    2002-01-01

    The dynamics of light in Fabry-Perot cavities with varying length and input laser frequency are analyzed. At high frequencies, the response to length variations is very different from the response to laser frequency variations. Implications for kilometer-scale Fabry-Perot cavities such as those utilized in gravitational-wave detectors are discussed

  14. Short Note Ground cavity nest temperatures and their relevance to ...

    African Journals Online (AJOL)

    Blue Swallows Hirundo atrocaerulea are Critically Endangered within South Africa. They nest in natural underground holes in mist-belt grasslands. Temperature dataloggers were used to record ground cavity nest (Tn) and ambient temperature (Ta) for one artificial and 11 natural Blue Swallow nests. Mean ground cavity Tn ...

  15. Toward more accurate loss tangent measurements in reentrant cavities

    Energy Technology Data Exchange (ETDEWEB)

    Moyer, R. D.

    1980-05-01

    Karpova has described an absolute method for measurement of dielectric properties of a solid in a coaxial reentrant cavity. His cavity resonance equation yields very accurate results for dielectric constants. However, he presented only approximate expressions for the loss tangent. This report presents more exact expressions for that quantity and summarizes some experimental results.

  16. High-R Walls for Remodeling. Wall Cavity Moisture Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Wiehagen, J. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States); Kochkin, V. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States)

    2012-12-01

    The focus of the study is on the performance of wall systems, and in particular, the moisture characteristics inside the wall cavity and in the wood sheathing. Furthermore, while this research will initially address new home construction, the goal is to address potential moisture issues in wall cavities of existing homes when insulation and air sealing improvements are made.

  17. Analysis of adiabatic transfer in cavity quantum electrodynamics

    Indian Academy of Sciences (India)

    A three-level atom in a configuration trapped in an optical cavity forms a basic unit in a number of proposed protocols for quantum information processing. This system allows for efficient storage of cavity photons into long-lived atomic excitations, and their retrieval with high fidelity, in an adiabatic transfer process through ...

  18. Ultrafast Dynamics of Vibration-Cavity Polariton Modes

    Science.gov (United States)

    Owrutsky, Jeff; Dunkelberger, Adam; Fears, Kenan; Simpkins, Blake; Spann, Bryan

    Vibrational modes of polymers, liquids, and solvated compounds can couple to Fabry-Perot optical cavity modes, creating vibration-cavity polariton modes whose energy tunes with the cavity length and incidence angle. Here we report the pump-probe infrared spectroscopy of vibration-cavity polaritons in cavity-coupled W(CO)6. At very early times, we observe quantum beating between the two polariton states find an anomalously low degree of excitation. After the quantum beating, we directly observe spectroscopic signatures of excited-state absorption from both polariton modes and uncoupled reservoir modes. An analytical expression for cavity transmission reproduces these signatures. The upper polariton mode relaxes ten times more quickly than the uncoupled vibrational mode and the polariton lifetime depends on the angle of incidence of the infrared pulses. Coupling to an optical cavity gives a means of control of the lifetime of vibration-cavity polaritons and could have important implications for chemical reactivity in vibrationally excited molecules.

  19. High-R Walls for Remodeling: Wall Cavity Moisture Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Wiehagen, J.; Kochkin, V.

    2012-12-01

    The focus of the study is on the performance of wall systems, and in particular, the moisture characteristics inside the wall cavity and in the wood sheathing. Furthermore, while this research will initially address new home construction, the goal is to address potential moisture issues in wall cavities of existing homes when insulation and air sealing improvements are made.

  20. Manufacturing of the L band 9-cell niobium cavity

    International Nuclear Information System (INIS)

    Matsuoka, Masanori; Ohkubo, Kohichi; Yamanaka, Toshiyuki; Kako, Eiji; Saito, Kenji; Shishido, Toshio; Ono, Masaaki; Noguchi, Shuichi.

    1993-01-01

    Since 1990, L-band niobium superconducting cavities have been developed with collaboration between our company and National Laboratory for High Energy Physics (KEK). The manufacturing procedure and the performance of 9-cell superconducting cavity are presented. The maximum accelerating gradient of 12 MV/m was attained in a cold test. (author)

  1. Cavity Ring-down Spectroscopic System And Method

    KAUST Repository

    Alquaity, Awad Bin Saud

    2015-05-14

    A system and method for cavity ring-down spectroscopy can include a pulsed quantum cascade laser, an optical ring-down cavity, a photodetector, and an oscilloscope. The system and method can produce pulse widths of less than 200 ns with bandwidths greater than 300 pm, as well as provide temporal resolution of greater than 10 .mu.s.

  2. Tree structure and cavity microclimate: implications for bats and birds.

    Science.gov (United States)

    Clement, Matthew J; Castleberry, Steven B

    2013-05-01

    It is widely assumed that tree cavity structure and microclimate affect cavity selection and use in cavity-dwelling bats and birds. Despite the interest in tree structure and microclimate, the relationship between the two has rarely been quantified. Currently available data often comes from artificial structures that may not accurately represent conditions in natural cavities. We collected data on tree cavity structure and microclimate from 45 trees in five cypress-gum swamps in the Coastal Plain of Georgia in the United States in 2008. We used hierarchical linear models to predict cavity microclimate from tree structure and ambient temperature and humidity, and used Aikaike's information criterion to select the most parsimonious models. We found large differences in microclimate among trees, but tree structure variables explained 80% of variation common to all trees. We argue that the determinants of microclimate are complex and multidimensional, and therefore cavity microclimate cannot be deduced easily from simple tree structures. Furthermore, we found that daily fluctuations in ambient conditions strongly affect microclimate, indicating that greater weather fluctuations will cause greater differences among tree cavities.

  3. [Stafne's cavity. Review and apropos of 6 cases].

    Science.gov (United States)

    Grau Cases, J; Gay Escoda, C; Hernández Alfaro, F

    1991-02-01

    A retrospective study of 6 cases of Stafne's static cavities is presented in a review of 1536 cases of maxillary cysts. We have found an incidence 4:2 for men. All cases have been detected casually. The sialography show a relationship between cavities and the submaxillary gland. The treatment was surgical in four cases and conservative in two.

  4. On unsteady reacting flow in a channel with a cavity

    Directory of Open Access Journals (Sweden)

    Ivar Ø. Sand

    1991-10-01

    Full Text Available The problem investigated is the stability of a flame anchored by recirculation within a channel with a cavity, acting as a two-dimensional approximation to a gas turbine combustion chamber. This is related to experiments of Vaneveld, Hom and Oppenheim (1982. The hypothesis studied is that hydrodynamic oscillations within the cavity can lead to flashback.

  5. A generic travelling wave solution in dissipative laser cavity

    Indian Academy of Sciences (India)

    2016-09-09

    Sep 9, 2016 ... Abstract. A large family of cosh-Gaussian travelling wave solution of a complex Ginzburg–Landau equation. (CGLE), that describes dissipative semiconductor laser cavity is derived. Using perturbation method, the stabil- ity region is identified. Bifurcation analysis is done by smoothly varying the cavity loss ...

  6. Single-cell LEP-type cavity on measurement stand

    CERN Multimedia

    CERN PhotoLab

    1982-01-01

    A single-cell cavity, made of copper, with tapered connectors for impedance measurements. It was used as a model of LEP-type superconducting cavities, to investigate impedance and higher-order modes and operated at around 600 MHz (the LEP acceleration frequency was 352.2 MHz). See 8202500.

  7. Integral storage-bulb and microwave cavity for masers

    Science.gov (United States)

    Reinhardt, V. S.

    1980-01-01

    Mechanically-stable integral storage-bulb/microwave cavity made out of single piece of fused quartz improves frequency stability. Single-piece construction eliminates joints, making cavity dimensionally and hence frequency-stable. Fused quartz is used because of its low thermal expansion coefficient.

  8. Biological and chemical characteristics of the coral gastric cavity

    Science.gov (United States)

    Agostini, S.; Suzuki, Y.; Higuchi, T.; Casareto, B. E.; Yoshinaga, K.; Nakano, Y.; Fujimura, H.

    2012-03-01

    All corals have a common structure: two tissue layers enclose a lumen, which forms the gastric cavity. Few studies have described the processes occurring inside the gastric cavity and its chemical and biological characteristics. Here, we show that the coral gastric cavity has distinct chemical characteristics with respect to dissolved O2, pH, alkalinity, and nutrients (vitamin B12, nitrate, nitrite, ammonium, and phosphate) and also harbors a distinct bacterial community. From these results, the gastric cavity can be described as a semi-closed sub-environment within the coral. Dissolved O2 shows very low constant concentrations in the deepest parts of the cavity, creating a compartmentalized, anoxic environment. The pH is lower in the cavity than in the surrounding water and, like alkalinity, shows day/night variations different from those of the surrounding water. Nutrient concentrations in the cavity are greater than the concentrations found in reef waters, especially for phosphate and vitamin B12. The source of these nutrients may be internal production by symbiotic bacteria and/or the remineralization of organic matter ingested or produced by the corals. The importance of the bacteria inhabiting the gastric cavity is supported by the finding of a high bacterial abundance and a specific bacterial community with affiliation to bacteria found in other corals and in the guts of other organisms. The findings presented here open a new area of research that may help us to understand the processes that maintain coral health.

  9. RF cavity using liquid dielectric for tuning and cooling

    Science.gov (United States)

    Popovic, Milorad [Warrenville, IL; Johnson, Rolland P [Newport News, VA

    2012-04-17

    A system for accelerating particles includes an RF cavity that contains a ferrite core and a liquid dielectric. Characteristics of the ferrite core and the liquid dielectric, among other factors, determine the resonant frequency of the RF cavity. The liquid dielectric is circulated to cool the ferrite core during the operation of the system.

  10. High pressure discharges in cavities formed by microfabrication techniques

    International Nuclear Information System (INIS)

    Khan, B.A.; Cammack, D.A.; Pinker, R.D.; Racz, J.

    1997-01-01

    High pressure discharges are the basis of small high intensity light sources. In this work, we demonstrate the formation of high pressure discharges, in cavities formed by applying micromachining and integrated circuit techniques to quartz substrates. Cavities containing varying amounts of mercury and argon were fabricated to obtain high pressure discharges. A high pressure mercury discharge was formed in the electrodeless cavities by exciting them with a microwave source, operating at 2.45 GHz and in the electroded cavities by applying a dc voltage. The contraction of the discharge into a high pressure arc was observed. A broad emission spectrum due to self-absorption and collisions between excited atoms and normal atoms, typical of high pressure mercury discharges, was measured. The light output and efficacy increased with increasing pressure. The measured voltage was used to estimate the pressure within the electroded cavities, which is as high as 127 atm for one of the two cavities discussed in this work. Efficacies over 40 lumens per watt were obtained for the electrodeless cavities and over 50 scr(l)m/W for the electroded cavities. copyright 1997 American Institute of Physics

  11. Nasal cavity of the farmed african catfish Clarias gariepinus ...

    African Journals Online (AJOL)

    The nasal cavity microanatomy of farmed fingerlings of African catfish, Clarias gariepunus was investigated to fill existing knowledge gap on its histology from available literatures. This becomes very important as no gustatory cell was reported from previous researches on the fingerling digestive tract. A slice of nasal cavity of ...

  12. Polarisation dynamics of a birefringent Fabry-Perot cavity

    Science.gov (United States)

    Ejlli, A.; Della Valle, F.; Zavattini, G.

    2018-02-01

    Optical Fabry-Perot cavities always show a non-degeneracy of two orthogonal polarisation states. This is due to the unavoidable birefringence of dielectric mirrors whose effects are extremely important in Fabry-Perot-based high-accuracy polarimeters: in birefringent cavities, ellipticities and rotations mix. We have developed and present here a theory of the polarisation state dynamics in a birefringent Fabry-Perot resonator, and we validate it through measurements performed with the polarimeter of the PVLAS experiment. The measurements are performed while a laser is frequency-locked to the cavity, and provide values for the phase difference between the two orthogonal polarisation components introduced by the combination of the two cavity mirrors (equivalent wave-plate) and for the finesse of the cavity. The theoretical formulas and the experimental data agree well showing that the consequences of the mirror birefringence must be taken into account in this and in any other similar experiment.

  13. Dependence of transmon qubit relaxation rate on cavity photon population

    Science.gov (United States)

    Mundhada, S. O.; Shankar, S.; Liu, Y.; Hatridge, M.; Narla, A.; Sliwa, K. M.; Girvin, S. M.; Devoret, M. H.

    2015-03-01

    In circuit QED experiments, a qubit is dispersively coupled to a cavity such that the cavity frequency depends on the qubit state. This dispersive shift enables quantum non-demolition readout of the qubit by exciting the cavity with a microwave pulse and detecting the phase shift of the reflected signal. However, this cavity excitation has been observed in experiments to increase the qubit relaxation rate, hence demolishing the qubit state and limiting the maximum measurement strength. Here we experimentally study this effect in a transmon qubit coupled to a three-dimensional superconducting cavity. We also explore alternate qubit circuits designed to mitigate this demolition effect. Work supported by: IARPA, ARO, and NSF.

  14. Benchmarking Microwave Cavity Dark Matter Searches using a Radioactive Source

    CERN Multimedia

    Caspers, F

    2014-01-01

    A radioactive source is proposed as a calibration device to verify the sensitivity of a microwave dark matter search experiment. The interaction of e.g., electrons travelling in an arbitrary direction and velocity through an electromagnetically “empty” microwave cavity can be calculated numerically. We give an estimation of the energy deposited by a charged particle into a particular mode. Numerical examples are given for beta emitters and two particular cases: interaction with a field free cavity and interaction with a cavity which already contains an electromagnetic field. Each particle delivers a certain amount of energy related to the modal R/Q value of the cavity. The transferred energy is a function of the particles trajectory and its velocity. It results in a resonant response of the cavity, which can be observed using a sensitive microwave receiver, provided that the deposited energy is significantly above the single photon threshold.

  15. A Pass Band Performance Simulation Code of Coupled Cavities

    CERN Document Server

    Tao, X

    2004-01-01

    A simulation code of accelerating cavities named PPSC is developed by the solutions of the microwave equivalent circuit equations. PPSC can give the pass band performance of periodic or non-periodic accelerating structures, such as the dispersion frequency and the reflection factor of the cavity, the field distribution of each mode and so on. The natural parameters of the structure, such as the number of the cavities, the resonant frequencies and Q-factors of each cavity, the coupling factor between two cavities, and the locations of the couplers, can be changed easily to see the different results of the simulation. The code is written based on MS Visual Basic under MS windows. With these, a user-friendly interface is made. Some simple examples was simulated and gave reliable results.

  16. Cavity formation by the impact of Leidenfrost spheres

    KAUST Repository

    Marston, Jeremy

    2012-05-01

    We report observations of cavity formation and subsequent collapse when a heated sphere impacts onto a liquid pool. When the sphere temperature is much greater than the boiling point of the liquid, we observe an inverted Leidenfrost effect where the sphere is encompassed by a vapour layer that prevents physical contact with the liquid. This creates the ultimate non-wetting scenario during sphere penetration through a free surface, producing very smooth cavity walls. In some cases during initial entry, however, the liquid contacts the sphere at the equator, leading to the formation of a dual cavity structure. For cold sphere impacts, where a contact line is observed, we reveal details of the contact line pinning, which initially forms a sawtooth pattern. We also observe surface waves on the cavity interface for cold spheres. We compare our experimental results to previous studies of cavity dynamics and, in particular, the influence of hydrophobicity on the entry of the sphere. © 2012 Cambridge University Press.

  17. Cavity preparation machine for the standardization of in vitro preparations

    Directory of Open Access Journals (Sweden)

    Carlos José Soares

    2008-09-01

    Full Text Available Several in vitro studies employ the confection of cavity preparations that are difficult to standardize by means of manual high speed handpieces. This study presents the development of a cavity preparation machine designed to standardize in vitro cavity preparations. A metal base of 25 mm x 25 mm x 4 mm (length x width x height was coupled to a small mobile table which was designed to be able to move by means of two precision micrometers (0.01-mm accuracy in the horizontal directions (right-left, and back-front. A high speed handpiece was coupled to a metallic connecting rod which had an accurate dial indicator enabling control of the vertical movement. The high speed handpiece is also able to move 180° around its longitudinal axis and 360° around its transversal axis. The suggested cavity preparation machine precisely helps in the standardization of cavity preparations for in vitro studies.

  18. Thermal Model of a Dish Stirling Cavity-Receiver

    Directory of Open Access Journals (Sweden)

    Rubén Gil

    2015-01-01

    Full Text Available This paper presents a thermal model for a dish Stirling cavity based on the finite differences method. This model is a theoretical tool to optimize the cavity in terms of thermal efficiency. One of the main outcomes of this work is the evaluation of radiative exchange using the radiosity method; for that purpose, the view factors of all surfaces involved have been accurately calculated. Moreover, this model enables the variation of the cavity and receiver dimensions and the materials to determine the optimal cavity design. The tool has been used to study the cavity optimization regarding geometry parameters and material properties. Receiver absorptivity has been identified as the most influential property of the materials. The optimal aperture height depends on the minimum focal space.

  19. Novel High Cooperativity Photon-Magnon Cavity QED

    Science.gov (United States)

    Tobar, Michael; Bourhill, Jeremy; Kostylev, Nikita; G, Maxim; Creedon, Daniel

    Novel microwave cavities are presented, which couple photons and magnons in YIG spheres in a super- and ultra-strong way at around 20 mK in temperature. Few/Single photon couplings (or normal mode splitting, 2g) of more than 6 GHz at microwave frequencies are obtained. Types of cavities include multiple post reentrant cavities, which co-couple photons at different frequencies with a coupling greater that the free spectral range, as well as spherical loaded dielectric cavity resonators. In such cavities we show that the bare dielectric properties can be obtained by polarizing all magnon modes to high energy using a 7 Tesla magnet. We also show that at zero-field, collective effects of the spins significantly perturb the photon modes. Other effects like time-reversal symmetry breaking are observed.

  20. Complex envelope control of pulsed accelerating fields in superconducting cavities

    CERN Document Server

    Czarski, T

    2010-01-01

    A digital control system for superconducting cavities of a linear accelerator is presented in this work. FPGA (Field Programmable Gate Arrays) based controller, managed by MATLAB, was developed to investigate a novel firmware implementation. The LLRF - Low Level Radio Frequency system for FLASH project in DESY is introduced. Essential modeling of a cavity resonator with signal and power analysis is considered as a key approach to the control methods. An electrical model is represented by the non-stationary state space equation for the complex envelope of the cavity voltage driven by the current generator and the beam loading. The electromechanical model of the superconducting cavity resonator including the Lorentz force detuning has been developed for a simulation purpose. The digital signal processing is proposed for the field vector detection. The field vector sum control is considered for multiple cavities driven by one klystron. An algebraic, complex domain model is proposed for the system analysis. The c...

  1. Millimeter-long fiber Fabry-Perot cavities.

    Science.gov (United States)

    Ott, Konstantin; Garcia, Sebastien; Kohlhaas, Ralf; Schüppert, Klemens; Rosenbusch, Peter; Long, Romain; Reichel, Jakob

    2016-05-02

    We demonstrate fiber Fabry-Perot (FFP) cavities with concave mirrors that can be operated at cavity lengths as large as 1.5 mm without significant deterioration of the finesse. This is achieved by using a laser dot machining technique to shape spherical mirrors with ultralow roughness and employing single-mode fibers with large mode area for good mode matching to the cavity. Additionally, in contrast to previous FFPs, these cavities can be used over an octave-spanning frequency range with adequate coatings. We also show directly that shape deviations caused by the fiber's index profile lead to a finesse decrease as observed in earlier attempts to build long FFP cavities, and show a way to overcome this problem.

  2. Heat transfer in window frames with internal cavities

    Energy Technology Data Exchange (ETDEWEB)

    Gustavsen, Arild

    2001-07-01

    Heat transfer in window frames with internal air cavities is studied in this thesis. Investigations focus on two- and three-dimensional natural convection effects inside air cavities, the dependence of the emissivity on the thermal transmittance, and the emissivity of anodized and untreated aluminium profiles. The investigations are mostly conducted on window frames which are the same size as real frames found in residential buildings. Numerical and experimental investigations were performed to study the effectiveness of one commercial Computational Fluid Dynamics (CFD) program for simulating combined natural convection and heat transfer in simple three-dimensional window frames with internal air cavities. The accuracy of the conjugate CFD simulations was evaluated by comparing results for surface temperature on the warm side of the specimens to results from experiments that use infrared (IR) thermography to map surface temperatures during steady-state thermal tests. In general, there was good agreement between the simulations and experiments. Two-dimensional computational fluid dynamic and conduction simulations are performed to study the difference between treating air cavities as a fluid and as a solid when calculating the thermal transmittance of window frames. The simulations show that traditional software codes, simulating only conduction and using equivalent conductivities for the air cavities, give Uvalues that compare well with results from fluid flow simulations. The difference between the two models are mostly limited to the temperature distribution inside air cavities. It is also found that cavities with an interconnection less than about 7 mm can be treated as separate cavities. Three-dimensional natural convection effects in simple and custom-made PVC and thermally broken aluminum window frames with one open internal cavity were studied, with the use of CFD simulations and thermography experiments. Focus was put on corner effects and heat transfer

  3. Researches on bake effect on RF superconducting cavities

    International Nuclear Information System (INIS)

    Hao Jiankui; Zhao Kui; Zhu Feng

    2005-01-01

    The Q-slope at high gradient affects the performance of superconducting cavity greatly. Recent researches show that low temperature (100-150) degree C heat treatment (bake) has positive effects on the performance of superconducting cavities. A lot of cavity tests are analyzed based on bake treatment. The average gradient E acc,max and E acc at Q=1 x 10 10 are increased by more than 3.5 MV/m. Q at E acc,max is increased and the Q-slope is improved. Analysis on bake temperature shows that higher bake temperature leads to higher Q value. Comparison of BCP and EP cavities shows that at least 60-80 μm EP is needed for BCP surface. More than 10-15 μm removal of the surface by BCP will degrade the performance of an EP cavity. Oxygen diffusion model is used to illustrate bake effect. (authors)

  4. Metastatic Tumours to the Oral Cavity: Report of Three Cases

    Directory of Open Access Journals (Sweden)

    Ioanna G. Kalaitsidou

    2015-12-01

    Full Text Available Background: Metastatic tumours to the oral cavity from distant organs are uncommon and represent approximately 1 - 3% of all oral malignancies. Such metastases can occur to the bone or to the oral soft tissues. Almost any malignancy from any site is capable of metastasis to the oral cavity and a wide variety of tumours have been reported to spread to the mouth. Methods: Careful examination of the oral cavity and a high degree of clinical suspicion as well as a multidisciplinary approach are suggested. Results: In this article we present three patients, a female and two males with metastatic tumours to the oral cavity, who were referred to our Department. The primary tumours were invasive lobular breast carcinoma, gastric adenocarcinoma and small cell lung carcinoma respectively. Conclusions: Metastases to the oral cavity are quite uncommon among population. They usually present with symptoms similar to odontogenic infections and benign tumours, causing a delayed diagnosis and treatment.

  5. Temperature Mapping of Nitrogen-doped Niobium Superconducting Radiofrequency Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Makita, Junki [Old Dominion Univ., Norfolk, VA (United States); Ciovati, Gianluigi [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Dhakal, Pashupati [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2015-09-01

    It was recently shown that diffusing nitrogen on the inner surface of superconducting radiofrequency (SRF) cavities at high temperature can improve the quality factor of the niobium cavity. However, a reduction of the quench field is also typically found. To better understand the location of rf losses and quench, we used a thermometry system to map the temperature of the outer surface of ingot Nb cavities after nitrogen doping and electropolishing. Surface temperature of the cavities was recorded while increasing the rf power and also during the quenching. The results of thermal mapping showed no precursor heating on the cavities and quenching to be ignited near the equator where the surface magnetic field is maximum. Hot-spots at the equator area during multipacting were also detected by thermal mapping.

  6. Apparatus and process for passivating an SRF cavity

    Science.gov (United States)

    Myneni, Ganapati Rao; Wallace, John P

    2014-12-02

    An apparatus and process for the production of a niobium cavity exhibiting high quality factors at high gradients is provided. The apparatus comprises a first chamber positioned within a second chamber, an RF generator and vacuum pumping systems. The process comprises placing the niobium cavity in a first chamber of the apparatus; thermally treating the cavity by high temperature in the first chamber while maintaining high vacuum in the first and second chambers; and applying a passivating thin film layer to a surface of the cavity in the presence of a gaseous mixture and an RF field. Further a niobium cavity exhibiting high quality factors at high gradients produced by the method of the invention is provided.

  7. Magnetic Flux Expulsion Studies in Niobium SRF Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Posen, Sam [Fermilab; Checchin, Mattia [Fermilab; Crawford, Anthony [Fermilab; Grassellino, Anna [Fermilab; Martinello, Martina [Fermilab; Melnychuk, Oleksandr [Fermilab; Romanenko, Alexander [Fermilab; Sergatskov, Dmitri [Fermilab; Trenikhina, Yulia [Fermilab

    2016-06-01

    With the recent discovery of nitrogen doping treatment for SRF cavities, ultra-high quality factors at medium accelerating fields are regularly achieved in vertical RF tests. To preserve these quality factors into the cryomodule, it is important to consider background magnetic fields, which can become trapped in the surface of the cavity during cooldown and cause Q₀ degradation. Building on the recent discovery that spatial thermal gradients during cooldown can significantly improve expulsion of magnetic flux, a detailed study was performed of flux expulsion on two cavities with different furnace treatments that are cooled in magnetic fields amplitudes representative of what is expected in a realistic cryomodule. In this contribution, we summarize these cavity results, in order to improve understanding of the impact of flux expulsion on cavity performance.

  8. Cavity quantum-electrodynamical response to a gravitational wave

    Energy Technology Data Exchange (ETDEWEB)

    Gerlach, U.H. (Department of Mathematics, Ohio State University, Columbus, Ohio 43210 (United States))

    1992-08-15

    What is the rate of information transfer from a gravitational wave (GW) transmitter to a receiver To this end we consider how electromagnetic modes in a cylindrical cavity respond to circularly polarized gravitational radiation. It is found that a GW changes the refractive index inside the cavity. In fact, the cavity interior becomes birefringent for electromagnetic modes circulating in opposite directions. A linearly polarized cavity mode is thus subjected to Faraday rotation by the GW. In addition, for a cavity mode circulating in the same sense as the GW, the refractive index becomes complex: the cavity interior exhibits antidamping, but only over a finite interval of the applied GW frequency. Inside this interval the cavity mode becomes unstable and its frequency locks onto one-half the GW frequency ( parametric excitation''). Outside this interval the cavity mode breaks the lock-in synchronization with the GW. Instead, the mode evolves in a stable fashion and, like a counterrotating mode, only suffers a frequency pulling away from its unperturbed value. The quantum-mechanical response of the cavity oscillator is expressed as a spinning top precessing around a fictitious magnetic field in a fictitious three-dimensional Lorentz space. In the absence of any impinging GW this magnetic field is timelike and straight up. In the presence of a GW this magnetic field gets changed. The vectorial change is directly related to the frequency and the maximum amplitude of the GW. The resultant magnetic field is tilted and timelike for stable evolution, but spacelike for unstable evolution. The set of observables of a simple harmonic oscillator (SHO) is decomposed into mutually exclusive and jointly exhaustive sets of spin-{ital j} objects. They make up the finite representations of the symmetry group of the three-dimensional Lorentz space arena for the cavity oscillator influenced by a GW.

  9. Filling a niche market: administering drugs by injection or infusion.

    Science.gov (United States)

    Kaldy, Joanne

    2015-05-01

    There is greater incentive than ever to keep individuals requiring injectable or infusion therapy in the nursing facility-and not transfer them to a hospital-to receive those services. There is a demand for pharmacists with the skills, knowledge, and training to provide these services. To make that possible, pharmacies and pharmacists with the proper equipment, supplies, knowledge, training, and expertise are needed to work closely with physicians and nurses to provide sterile, properly compounded products and ensure that drugs are administered appropriately and in the right doses. These pharmacists also can work with facilities and practitioners to assess, improve, and document quality.

  10. Biologic effects of orally administered deuterium oxide on rat liver.

    Science.gov (United States)

    Kanwar, K C; Verma, R

    1977-01-01

    Rats were made to drink D2O mixed water (30: 70) for 6 weeks in order to study the biological effects of orally administered D2O on the liver. Heavy water administration results in gradual decrease in the body weight whereas the liver showed marginal increase in weight throughout the experimental period. Phosphatases and dehydrogenases were analyzed biochemically. Acid phosphatase, glucose-6-phosphatase and adenosine triphosphatase registered fall in contrast to alkaline phosphatase, SDH and LDH, all of which showed a definite increase. Lipids, nucleic acids and proteins, estimated biochemically, gradually decreased throughout the experimental period in response to D2O feeding.

  11. A screening program for dancers administered by dancers.

    Science.gov (United States)

    Wilson, Margaret; Deckert, Jennifer L

    2009-01-01

    Students enrolled in a dance kinesiology class were trained to administer a screening protocol on younger dancers in the same department. The dance kinesiology students gained experience assessing alignment and functional symmetry in their peers, and then recommended exercises for gaining awareness and developing balanced patterns of movement. This "low stakes" assessment created both dialogue and peer support centered on helping the screened dancers understand and effectively work with their individual capacities and limitations. The project was designed to contribute to a culture of wellness and education within the dance department.

  12. Superconducting Prototype Cavities for the Spallation Neutron Source (SNS) Project

    International Nuclear Information System (INIS)

    Ciovati, G.; Kneisel, P.; Brawley, J.; Bundy, R.; Campisi, I.; Davis, K.; Macha, K.; Machie, D.; Mammosser, J.; Morgan, S.; Sundelin, R.; Turlington, L.; Wilson, K.; Doleans, M.; Kim, S.H.; Barni, D.; Pagani, C.; Pierini, P.; Matsumoto, K.; Mitchell, R.; Schrage, D.; Parodi, R.; Sekutowicz, J.; Ylae-Oijala, P.

    2001-01-01

    The Spallation Neutron Source project includes a superconducting linac section in the energy range from 192 MeV to 1000 MeV, operating at a frequency of 805 MHz at 2.1 K. For this energy range two types of cavities are needed with geometrical beta - values of beta= 0.61 and beta= 0.81. An aggressive cavity prototyping program is being pursued at Jlab, which calls for fabricating and testing of four beta= 0.61 cavities and two beta= 0.81 cavities. Both types consist of six cells made from high purity niobium and feature one HOM coupler on each beam pipe and a port for a high power coaxial input coupler. Three of the four beta= 0.61 cavities will be used for a cryomodule test in early 2002. At this time four medium beta cavities and one high beta cavity have been completed at JLab. The first tests on the beta=0.61 cavity and the beta= 0.81 exceeded the design values for gradient and Q - value: E acc = 1 0.3 MV/m and Q = 5 x 10 9 at 2.1K for beta= 0.61 and E acc = 12.3 MV/m and Q = 5 x 10 9 at 2.1K for beta= 0.81. One of the medium beta cavities has been equipped with an integrated helium vessel and measurements of the static and dynamic Lorentz force detuning will be done and compared to the ''bare'' cavities. In addition two single cell cavities have been fabricated, equipped with welded-on HOM couplers. They are being used to evaluate the HOM couplers with respect to multipacting, fundamental mode rejection and HOM damping as far as possible in a single cell. This paper will describe the cavity design with respect to electrical and mechanical features, the fabrication efforts and the results obtained with the different cavities existing at the time of this workshop

  13. Metabolic fate of orally administered enzymatically synthesized glycogen in rats.

    Science.gov (United States)

    Furuyashiki, Takashi; Takata, Hiroki; Kojima, Iwao; Kuriki, Takashi; Fukuda, Itsuko; Ashida, Hitoshi

    2011-04-01

    We developed a new process for enzymatically synthesized glycogen (ESG), which is equivalent in physicochemical properties to natural-source glycogen (NSG) except its resistant property to degradation by α-amylase in vitro. In this study the metabolic fates of orally administered ESG in rats were investigated by a single oral administration test and a 2 week ingestion test. The glycemic index of ESG was 79. After the 2 week ingestion of ESG, the cecal content and production of short chain fatty acids were significantly increased, the pH value of cecal content was lowered, and the counts of Bifidobacterium and Lactobacillus in feces were significantly increased. Additionally, plasma levels of triacylglycerol and total cholesterol were significantly reduced by ESG. In contrast, NSG did not affect these parameters at all. The results collectively suggest that around 20% of orally administered ESG was transferred to the cecum in the form of polymer and assimilated into short chain fatty acids by microbiota and the polymer affected lipid metabolism.

  14. Metabolism of exogenously administered natural surfactant in the newborn lamb

    Energy Technology Data Exchange (ETDEWEB)

    Glatz, T.; Ikegami, M.; Jobe, A.

    1982-09-01

    (/sup 3/H)-Palmitate labeled natural lamb surfactant and free (/sup 14/C)-choline were mixed with the lung fluid of 11 term lambs at cesarean section, before the first breath. After receiving the isotope, the lambs were delivered, allowed to breathe spontaneously, and were subsequently sacrificed from 5 min to 96 h of age. Alveolar washes, lung homogenates, microsomal and lamellar body fractions of lungs, and pulmonary alveolar macrophages were examined for the presence of labeled phosphatidylcholine. Analysis of the labeled natural surfactant kinetic data revealed an apparent t 1/2 of phosphatidylcholine in the whole lung of 6.0 days. This half-life can be interpreted only as a rough estimate. Appearance of considerable (/sup 3/H) labeled phosphatidylcholine in the lung homogenates demonstrated uptake of phosphatidylcholine from alveoli into lung tissue. The surfactant-associated label in homogenates was localized preferentially to lamellar body fractions. Some of the administered (/sup 14/C)-choline appeared in phosphatidylcholine. Almost all of this labeled phosphatidylcholine was associated with the homogenate. Extremely small % of administered (3H) and (14C) were found in pulmonary alveolar macrophages.

  15. Primary malignant melanoma of the nasal cavity.

    Science.gov (United States)

    Uysal, Ismail Önder; Misir, Mustafa; Polat, Kerem; Altuntaş, Emine Elif; Atalar, Mehmet Haydar; Tuncer, Ersin; Müderris, Suphi

    2012-01-01

    Primary malignant melanoma of the nose and paranasal sinus mucosa is a rare disease and seen in less than 1% among all melanomas. Malignant melanomas have 2 origins: cutaneous and mucosal. The mucosal form has a worse prognosis because of its aggressiveness compared with that of the cutaneous form. Mucosal melanomas often occur at a rate of 2% to 3% among all melanomas and are typically found in the nasal cavity and paranasal sinuses. Generally, it is more common in males and in those older than 50 years. In this study, 4 patients were observed at the Cumhuriyet University Faculty of Medicine; 2 of them were a 64-year-old man and an 82-year-old woman who had a malignant melanoma originating from the nasal septal mucosa, 1 patient was a 72-year-old woman whose malignant melanoma originated from the inferior turbinate, and 1 patient was a 77-year-old woman with a sinonasally located melanoma. The conditions of these patients were discussed under the light of literature instructions.

  16. Heat transfer in rotor/stator cavity

    Science.gov (United States)

    Tuliszka-Sznitko, Ewa; Majchrowski, Wojciech; Kiełczewski, Kamil

    2011-12-01

    In the paper we analyze the results of DNS/LES of the flow with heat transfer in the rotor/stator cavity. The rotor and the outer cylinder are heated. Computations have been performed for wide range of Reynolds numbers and aspect ratios. Computations are based on the efficient pseudo-spectral Chebyshev-Fourier method. In LES we used a Lagrangian dynamic subgrid-scale model of turbulence. Analysis allowed to check the influence of the aspect ratio and Reynolds number on the statistics and the structure of the flow. We analyzed all six Reynolds stress tensor components, turbulent fluctuations, three turbulent heat fluxes and different structural parameters which can be useful for modeling purposes. The distributions of Nusselt numbers obtained for different Re and aspect rations along disks are given. We also investigated influence of thermal Rosssby number as well as distributions of temperature along heated disk on statistics. Computations have shown that turbulence is mostly concentrated in the stator boundary layer with a maximum at the junction between the stator and the outer cylinder. The results are compared to the experimental and numerical data taken from literature.

  17. Dynamic Color Displays Using Stepwise Cavity Resonators.

    Science.gov (United States)

    Chen, Yiqin; Duan, Xiaoyang; Matuschek, Marcus; Zhou, Yanming; Neubrech, Frank; Duan, Huigao; Liu, Na

    2017-09-13

    High-resolution multicolor printing based on pixelated optical nanostructures is of great importance for promoting advances in color display science. So far, most of the work in this field has been focused on achieving static colors, limiting many potential applications. This inevitably calls for the development of dynamic color displays with advanced and innovative functionalities. In this Letter, we demonstrate a novel dynamic color printing scheme using magnesium-based pixelated Fabry-Pérot cavities by gray scale nanolithography. With controlled hydrogenation and dehydrogenation, magnesium undergoes unique metal and dielectric transitions, enabling distinct blank and color states from the pixelated Fabry-Pérot resonators. Following such a scheme, we first demonstrate dynamic Ishihara plates, in which the encrypted images can only be read out using hydrogen as information decoding key. We also demonstrate a new type of dynamic color generation, which enables fascinating transformations between black/white printing and color printing with fine tonal tuning. Our work will find wide-ranging applications in full-color printing and displays, colorimetric sensing, information encryption and anticounterfeiting.

  18. The MEDICI reactor cavity model: Chapter 5

    International Nuclear Information System (INIS)

    Bergeron, K.D.; Trebilcock, W.

    1983-01-01

    The MEDICI reactor cavity model is currently under development with the goal of providing a flexible, relatively realistic treatment of ex-vessel severe accident phenomena suitable for large system codes like CONTAIN and MELCOR. The code is being developed with an emphasis on top-down design, to facilitate adaptability and multiple applications. A brief description of the overall code structure is provided. One of the key new models is then described in more detail. This is a dynamic quench model for debris beds. An example calculation using this model is presented. The question of whether it is necessary to consider the simultaneous motion of the quench front and ablation of the concrete is addressed with some scoping models. It is found that for realistic parameters and coolable beds, concrete ablation is too slow a process to be important on the quenching time scale. Remelt in the dry zone, however, is found to be potentially important on this time scale, so quench and remelt are considered simultaneously

  19. Modeling of Coupled Nano-Cavity Lasers

    DEFF Research Database (Denmark)

    Skovgård, Troels Suhr

    Modeling of nanocavity light emitting semiconductor devices is done using the semiconductor laser rate equations with spontaneous and stimulated emission terms modified for Purcell enhanced recombination. The modified terms include details about the optical and electronic density-of-states and it......Modeling of nanocavity light emitting semiconductor devices is done using the semiconductor laser rate equations with spontaneous and stimulated emission terms modified for Purcell enhanced recombination. The modified terms include details about the optical and electronic density......-of-states relative to the optical density-of-states. The low effective Purcell eect for quantum well devices limits the highest possible modulation bandwidth to a few tens of gigahertz, which is comparable to the performance of conventional diode lasers. Compared to quantum well devices, quantum dot devices have...... is useful for design of coupled systems. A tight-binding description for coupled nanocavity lasers is developed and employed to investigate the phase-locking behavior for the system of two coupled cavities. Phase-locking is found to be critically dependent on exact parameter values and to be dicult...

  20. Gross morphology of rhea oropharyngeal cavity

    Directory of Open Access Journals (Sweden)

    Marcio N. Rodrigues

    2012-12-01

    Full Text Available The rhea (Rhea americana americana is an american bird belonging to Ratite's family. Studies related to its morphology are still scarce. This study aims to describe the macroscopic structures of the oropharyngeal cavity. Five heads (2 to 6 months old formalin preserved were anatomically dissected to expose the oropharynx. The oropharynx of the rhea was "bell-shaped" composed by the maxillary and mandibular rhamphotheca. The roof and floor presented two distinct regions different in colour of the mucosa. The rostral region was pale pink contrasting to grey coloured caudal region. The median longitudinal ridge extended rostrally from the apex of the choana to the tip of the beak in the roof and it is clearly more prominent and rigid than the homolog in the floor that appeared thin and stretched merely along the rostral portion of the regio interramalis. The floor was formed by the interramal region, (regio interramalis tongue and laryngeal mound containing glove-shaped glottis. This study confirmed the basic morphology of the oropharinx of the rhea. However, important morphological information not previously described is highlighted and contradictory information present in the literature is clarified.

  1. Development and application of 3D RF cavity code MAFIA

    International Nuclear Information System (INIS)

    Gao Tieta

    1992-01-01

    The design of a asymmetric RF cavity requires a code that can treat 3D structure. This paper describes the characteristics, functions and applications of the 3D RF cavity computer-aided design (CAD) program MAFIA. The 3D geometry design of non-axial symmetric RF cavity with a coupler is realized by CAD method. A kind of data input is presented that can save not only machine memory, but also the CPU time, and large programs can be run on a medium-small size machine. The numerical simulation of a L-band RF cavity is presented and the modeling results agree well with its experimental values. We have also compared electric properties of the RF cavity with variant geometry by applying 3D numerical and graphic simulations. The influence on electric and magnetic fields by adding a input coupler or HOM coupler at the side of a RF cavity is analysed. Adding a coupler to a RF cavity can cause the change of resonance frequency. A method that can compensate the variation of frequency is also presented

  2. Cavity RF mode analysis using a boundary-integral method

    International Nuclear Information System (INIS)

    Jong, M.S. de; Adams, F.P.

    1993-01-01

    A 3-dimensional boundary-integral method has been developed for rf cavity mode analysis. A frequency-dependent, homogeneous linear matrix equation is generated from a variant of the magnetic field integral equation (MFIE) where the domain of integration is a closed surface specifying the rf envelope of the cavity. Frequencies at which the MFIE has non-zero solutions are mode frequencies of the cavity, and the solutions are the corresponding surface magnetic field distributions. The MFIE can then be used to calculate the electric and magnetic field at any other point inside the cavity. Forward iteration is used to find the largest complex eigenvalue of the matrix at a specific frequency. This eigenvalue is 1 when the frequency corresponds to a cavity rf resonance. The matrix equivalent of the MFIE is produced by approximating the cavity surface by a set of perfectly conducting surface elements, and assuming that the surface magnetic field has constant amplitude on each element. The method can handle cavities with complex symmetries, and be easily integrated with finite-element heat-transfer and stress analysis codes

  3. The use of microperforated plates to attenuate cavity resonances

    DEFF Research Database (Denmark)

    Fenech, Benjamin; Keith, Graeme; Jacobsen, Finn

    2006-01-01

    The use of microperforated plates to introduce damping in a closed cavity is examined. By placing a microperforated plate well inside the cavity instead of near a wall as traditionally done in room acoustics, high attenuation can be obtained for specific acoustic modes, compared with the lower at......'s functions. The results, which are validated experimentally, show that a microperforated plate can provide substantial attenuation of modes in a cavity. One possible application of these findings is the treatment of boiler tones in heat-exchanger cavities.......The use of microperforated plates to introduce damping in a closed cavity is examined. By placing a microperforated plate well inside the cavity instead of near a wall as traditionally done in room acoustics, high attenuation can be obtained for specific acoustic modes, compared with the lower...... attenuation that can be obtained in a broad frequency range with the conventional position of the plate. An analytical method for predicting the attenuation is presented. The method involves finding complex eigenvalues and eigenfunctions for the modified cavity and makes it possible to predict Green...

  4. Surface processing for bulk niobium superconducting radio frequency cavities

    Science.gov (United States)

    Kelly, M. P.; Reid, T.

    2017-04-01

    The majority of niobium cavities for superconducting particle accelerators continue to be fabricated from thin-walled (2-4 mm) polycrystalline niobium sheet and, as a final step, require material removal from the radio frequency (RF) surface in order to achieve performance needed for use as practical accelerator devices. More recently bulk niobium in the form of, single- or large-grain slices cut from an ingot has become a viable alternative for some cavity types. In both cases the so-called damaged layer must be chemically etched or electrochemically polished away. The methods for doing this date back at least four decades, however, vigorous empirical studies on real cavities and more fundamental studies on niobium samples at laboratories worldwide have led to seemingly modest improvements that, when taken together, constitute a substantial advance in the reproducibility for surface processing techniques and overall cavity performance. This article reviews the development of niobium cavity surface processing, and summarizes results of recent studies. We place some emphasis on practical details for real cavity processing systems which are difficult to find in the literature but are, nonetheless, crucial for achieving the good and reproducible cavity performance. New approaches for bulk niobium surface treatment which aim to reduce cost or increase performance, including alternate chemical recipes, barrel polishing and ‘nitrogen doping’ of the RF surface, continue to be pursued and are closely linked to the requirements for surface processing.

  5. Recent Developments in SRF Cavity Science and Performance

    Energy Technology Data Exchange (ETDEWEB)

    G. Ciovati

    2006-08-10

    The performances of SRF cavities made of high purity bulk niobium have been improving in the last few years and surface magnetic fields (Bp) close to the thermodynamic critical field of niobium have been achieved in a few cases. The recommendation made in 2004 in favor of SRF as the technology of choice for the International Linear Collider (ILC), requires improving the reliability of multi-cell cavities operating at accelerating gradients (Eacc) of the order of 35 MV/m. Additionally, a better understanding of the present limitations to cavity performance, such as the high-field Q-drop is needed. This contribution presents some recent developments in SRF cavity science and performance. Among the most significant advances of the last few years, new cavity shapes with lower ratio Bp/Eacc were designed and tested. Cavities made of large-grain niobium became available, promising lower cost at comparable performance to standard fine-grain ones and several tests on single-cell cavities were done to gain a better understanding of high-field losses. In addition, studies to improve the reliability of electropolishing are being carried out by several research groups.

  6. Momentum diffusion for coupled atom-cavity oscillators

    International Nuclear Information System (INIS)

    Murr, K.; Maunz, P.; Pinkse, P. W. H.; Puppe, T.; Schuster, I.; Rempe, G.; Vitali, D.

    2006-01-01

    It is shown that the momentum diffusion of free-space laser cooling has a natural correspondence in optical cavities when the internal state of the atom is treated as a harmonic oscillator. We derive a general expression for the momentum diffusion, which is valid for most configurations of interest: The atom or the cavity or both can be probed by lasers, with or without the presence of traps inducing local atomic frequency shifts. It is shown that, albeit the (possibly strong) coupling between atom and cavity, it is sufficient for deriving the momentum diffusion to consider that the atom couples to a mean cavity field, which gives a first contribution, and that the cavity mode couples to a mean atomic dipole, giving a second contribution. Both contributions have an intuitive form and present a clear symmetry. The total diffusion is the sum of these two contributions plus the diffusion originating from the fluctuations of the forces due to the coupling to the vacuum modes other than the cavity mode (the so-called spontaneous emission term). Examples are given that help to evaluate the heating rates induced by an optical cavity for experiments operating at low atomic saturation. We also point out intriguing situations where the atom is heated although it cannot scatter light

  7. Photodynamic Therapy Using Temoporfin Before Surgery in Treating Patients With Recurrent Oral Cavity or Oropharyngeal Cancer

    Science.gov (United States)

    2014-09-02

    Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Stage I Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage I Squamous Cell Carcinoma of the Oropharynx; Stage I Verrucous Carcinoma of the Oral Cavity; Stage II Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage II Squamous Cell Carcinoma of the Oropharynx; Stage II Verrucous Carcinoma of the Oral Cavity; Tongue Cancer

  8. The quest for high-gradient superconducting cavities

    International Nuclear Information System (INIS)

    Padamsee, H.

    1999-01-01

    Superconducting RF cavities excel in applications requiring continuous waves or long pulse voltages. Since power losses in the walls of the cavity increase as the square of the accelerating voltage, copper cavities become uneconomical as demand for high continuous wave voltage grows with particle energy. For these reasons, RF superconductivity has become an important technology for high energy and high luminosity accelerators. The state of art in performance of sheet metal niobium cavities is best represented by the statistics of more than 300 5-cell, 1.5-GHz cavities built for CEBAF. Key aspects responsible for the outstanding performance of the CEBAF cavities set are the anti-multipactor, elliptical cell shape, good fabrication and welding techniques, high thermal conductivity niobium, and clean surface preparation. On average, field emission starts at the electric field of 8.7 MV/m, but there is a large spread, even though the cavities received nominally the same surface treatment and assembly procedures. In some cavities, field emission was detected as low as 3 MV/m. In others, it was found to be as high as 19 MV/m. As we will discuss, the reason for the large spread in the gradients is the large spread in emitter characteristics and the random occurrence of emitters on the surface. One important phenomenon that limits the achievable RF magnetic field is thermal breakdown of superconductivity, originating at sub-millimeter-size regions of high RF loss, called defects. Simulation reveal that if the defect is a normal conducting region of 200 mm radius, it will break down at 5 MV/m. Producing high gradients and high Q in superconducting cavities demands excellent control of material properties and surface cleanliness. The spread in gradients that arises from the random occurrence of defects and emitters must be reduced. It will be important to improve installation procedures to preserve the excellent gradients now obtained in laboratory test in vertical cryostats

  9. Optical re-injection in cavity-enhanced absorption spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Leen, J. Brian, E-mail: b.leen@lgrinc.com; O’Keefe, Anthony [Los Gatos Research, 67 E. Evelyn Avenue, Suite 3, Mountain View, California 94041 (United States)

    2014-09-15

    Non-mode-matched cavity-enhanced absorption spectrometry (e.g., cavity ringdown spectroscopy and integrated cavity output spectroscopy) is commonly used for the ultrasensitive detection of trace gases. These techniques are attractive for their simplicity and robustness, but their performance may be limited by the reflection of light from the front mirror and the resulting low optical transmission. Although this low transmitted power can sometimes be overcome with higher power lasers and lower noise detectors (e.g., in the near-infrared), many regimes exist where the available light intensity or photodetector sensitivity limits instrument performance (e.g., in the mid-infrared). In this article, we describe a method of repeatedly re-injecting light reflected off the front mirror of the optical cavity to boost the cavity's circulating power and deliver more light to the photodetector and thus increase the signal-to-noise ratio of the absorption measurement. We model and experimentally demonstrate the method's performance using off-axis cavity ringdown spectroscopy (OA-CRDS) with a broadly tunable external cavity quantum cascade laser. The power coupled through the cavity to the detector is increased by a factor of 22.5. The cavity loss is measured with a precision of 2 × 10{sup −10} cm{sup −1}/√(Hz;) an increase of 12 times over the standard off-axis configuration without reinjection and comparable to the best reported sensitivities in the mid-infrared. Finally, the re-injected CRDS system is used to measure the spectrum of several volatile organic compounds, demonstrating the improved ability to resolve weakly absorbing spectroscopic features.

  10. Evaluation of the Helicobacteraceae in the oral cavity of dogs.

    Science.gov (United States)

    Craven, Melanie; Recordati, Camilla; Gualdi, Valentina; Pengo, Graziano; Luini, Mario; Scanziani, Eugenio; Simpson, Kenneth W

    2011-11-01

    To determine the Helicobacter spp present in the oral cavity of dogs and the relationship of those organisms with gastric Helicobacter spp to better define the potential for dog-human and dog-dog transmission. Saliva and dental plaque from 28 dogs and gastric biopsy specimens from a subset of 8 dogs. PCR-based screening for Helicobacter spp was conducted on samples obtained from the oral cavity of 28 dogs. Comparative analysis was conducted on Helicobacteraceae 16S rDNA clone libraries from the oral cavity and stomach of a subset of 8 dogs (5 vomiting and 3 healthy) that had positive PCR results for Helicobacter spp. Helicobacteraceae DNA was identified in the oral cavity of 24 of 28 dogs. Analysis of cloned 16S rDNA amplicons from 8 dogs revealed that Wolinella spp was the most common (8/8 dogs) and abundant (52/57 [91%] clones) member of the Helicobacteraceae family in the oral cavity. Only 2 of 8 dogs harbored Helicobacter spp in the oral cavity, and 1 of those was coinfected with Helicobacter heilmannii and Helicobacter felis in samples obtained from the stomach and saliva. Evaluation of oral cavity DNA with Wolinella-specific PCR primers yielded positive results for 16 of 20 other dogs (24/28 samples were positive for Wolinella spp). Wolinella spp rather than Helicobacter spp were the predominant Helicobacteraceae in the oral cavity of dogs. The oral cavity of dogs was apparently not a zoonotically important reservoir of Helicobacter spp that were non-Helicobacter pylori organisms.

  11. Novel deflecting cavity design for eRHIC

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Q.; Belomestnykh, S.; Ben-Zvi, I.

    2011-07-25

    To prevent significant loss of the luminosity due to large crossing angle in the future ERL based Electron Ion Collider at BNL (eRHIC), there is a demand for crab cavities. In this article, we will present a novel design of the deflecting/crabbing 181 MHz superconducting RF cavity that will fulfil the requirements of eRHIC. The quarter-wave resonator structure of the new cavity possesses many advantages, such as compact size, high R{sub t}/Q, the absence of the same order mode and lower order mode, and easy higher order mode damping. We will present the properties and characteristics of the new cavity in detail. As the accelerator systems grow in complexity, developing compact and efficient deflecting cavities is of great interest. Such cavities will benefit situations where the beam line space is limited. The future linac-ring type electron-ion collider requires implementation of a crab-crossing scheme for both beams at the interaction region. The ion beam has a long bunches and high rigidity. Therefore, it requires a low frequency, large kicking angle deflector. The frequency of the deflecting mode for the current collider design is 181 MHz, and the deflecting angle is {approx}5 mrad for each beam. At such low frequency, the previous designs of the crab cavities will have very large dimensions, and also will be confronted by typical problems of damping the Lower Order Mode (LOM), the Same Order Mode (SOM), and as usual, the Higher Order Modes (HOM). In this paper we describe how one can use the concept of a quarter-wave (QW) resonator for a deflecting/crabbing cavity, and use its fundamental mode to deflect the beam. The simplicity of the cavity geometry and the large separation between its fundamental mode and the first HOM make it very attractive.

  12. On the applicability of conventional transmission line theory within cavities

    Directory of Open Access Journals (Sweden)

    F. Gronwald

    2006-01-01

    Full Text Available We investigate whether or not conventional transmission line theory needs to be modified if transmission lines are considered that are located in a cavity rather than in free space. Our analysis is based on coupled Pocklington's equations that can be reduced to integral equations for the antenna mode and the transmission line mode. Under the usual assumptions of conventional transmission line theory these modes do approximately decouple within a cavity. As a result, cavity properties will primarily influence the antenna mode but not the transmission line mode.

  13. Calculation of mechanical vibration frequencies of stiffened superconducting cavities

    International Nuclear Information System (INIS)

    Black, S.J.; Spalek, G.

    1992-01-01

    We calculated the frequencies of transverse and longitudinal mechanical-vibration modes of the HEPL- modified, CERN/DESY four-cell superconducting cavity, using finite-element techniques. We compared the results of these calculations, including the stiffening of the cavity with rods, with mode frequencies measured at HEPL. The correlation between data was significant. The same techniques were also used to design and optimize the stiffening scheme for the seven-cell 805-MHz superconducting cavity being developed at Los Alamos. In this report, we describe the final stiffening scheme and the results of our calculations

  14. Status of SCRF cavity and ADS development in Japan

    International Nuclear Information System (INIS)

    Yamamoto, Akira

    2011-01-01

    SCRF cavity technology has progressed with high-energy particle accelerator programs in Japan. It was first applied for TRISTAN program at KEK, in early 1980s, and it is expected to be a key technology to realize the next energy-frontier lepton collider such as ILC, and/or intensity-frontier proton accelerators hopefully to be realized in Japan. The JPARC project as a joint program between JAEA and KEK is scoping to realize ADS program with the linac upgrade using a superconducting cavity system, as a future program. The talk will cover an overview of the SCRF cavity development and the ADS development in Japan. (author)

  15. Open waveguide cavity using a negative index medium.

    Science.gov (United States)

    Yan, Wei; Shen, Linfang

    2008-12-01

    An open waveguide cavity formed by a pair of planar waveguides, in which one guiding layer is a negative index medium and the other is a positive index medium, is theoretically demonstrated. For such a waveguide cavity the resonant frequency is independent of the total length of the waveguide system. With the coupled mode theory it is shown that energy flow circulation can be established through the special coupling between the waveguides at the resonant frequency, and thus the wave fields are localized. This phenomenon is further verified numerically with the finite-difference time-domain method. The quality factor of the open waveguide cavity is also discussed.

  16. Squeezing-enhanced measurement sensitivity in a cavity optomechanical system

    DEFF Research Database (Denmark)

    Kerdoncuff, Hugo; Hoff, Ulrich Busk; Harris, Glen I.

    2015-01-01

    We determine the theoretical limits to squeezing-enhanced measurement sensitivity of mechanical motion in a cavity optomechanical system. The motion of a mechanical resonator is transduced onto quadrature fluctuations of a cavity optical field and a measurement is performed on the optical field...... exiting the cavity. We compare measurement sensitivities obtained with coherent probing and quantum-enhanced probing of the mechanical motion, i.e. the coherent probe field carries vacuum states and quadrature squeezed vacuum states at sideband frequencies, respectively. We find that quantum...

  17. Wakefield calculation for superconducting TM110 cavity without azimuthal symmetry

    Energy Technology Data Exchange (ETDEWEB)

    Bellantoni, Leo; /Fermilab; Burt, Graeme; /Lancaster U.

    2006-08-01

    The 3.9GHz TM{sub 110} mode deflecting cavity developed at FNAL has many applications, including use as a longitudinal bunch profile diagnostic, and as a crab cavity candidate for the ILC. These applications involve beams with substantial time structure. For the 13-cell version intended for the bunch profile application, long-range wakes have been evaluated in the frequency domain and short-range wakes have been evaluated in the time domain. Higher-order interactions of the main field in the cavity with the beam have also been parameterized. Pedagogic derivations are included as appendices.

  18. RF-cavity for the X-ray generator NESTOR

    International Nuclear Information System (INIS)

    Androsov, V.P.; Gvozd, A.M.; Karnaukhov, I.M.; Telegin, Yu.N.; Chernov, K.N.; Ostreyko, G.N.; Sedlyarov, I.K.

    2007-01-01

    In the Kharkov Institute of Physics and Technology 225 MeV electron storage ring NESTOR is under development. The paper describes the design and parameters of a 700 MHz cavity that has been fabricated at BINP for the NESTOR RF-system. Now the low-power and vacuum tests of the cavity are under way at BINP. We present here the results of 3D simulations of the cavity with ANSYS code. The problem of multibunch instabilities in NESTOR is also discussed

  19. A fast cavity dumper for a picosecond glass laser

    Science.gov (United States)

    Oak, S. M.; Bindra, K. S.; Narayan, B. S.; Khardekar, R. K.

    1991-02-01

    A fast cavity dumper for picosecond glass laser has been made. The optical and electrical characterization of the cavity dumper is described. An avalanche transistor Marx bank generator drives the cavity dumper. Up to 5 kV peak amplitude and 1.5 ns fall time negative polarity step pulses are generated by the Marx bank circuit. With a capacitive load like Pockels cell the pulse fall time increases to 4 ns. Optical switching times as fast as 2 ns (10%-90%) are experimentally measured. The contrast ratio of 1000 is obtained after a double pass through an amplifier. Single picosecond pulses are produced with an energy jitter of 10%.

  20. First prototype Copper-Niobium RF Superconducting Cavity

    CERN Multimedia

    1983-01-01

    This is the first RF superconducting cavity made of copper with a very thin layer of pure niobium deposited on the inner wall by sputtering. This new developpment lead to a considerable increase of performance and stability of superconducting cavities and to non-negligible economy. The work was carried out in the ISR workshop. This technique was adopted for the LEP II accelerating cavities. At the centre is Cristoforo Benvenuti, inventor of this important technology, with his assistants, Nadia Circelli and Max Hauer, carrying the sputtering electrode. See also 8209255, 8312339.

  1. Study of medium beta elliptical cavities for CADS

    Science.gov (United States)

    Wen, Liangjian; Zhang, Shenghu; Li, Yongming; Wang, Ruoxu; Guo, Hao; Zhang, Cong; Jia, Huan; Jiang, Tiancai; Li, Chunlong; He, Yuan

    2016-02-01

    The China Accelerator-Driven Sub-critical System (CADS) is a high intensity proton facility to dispose of nuclear waste and generate electric power. CADS is based on a 1.5 GeV, 10 mA CW superconducting (SC) linac as a driver. The high energy section of the linac is composed of two families of SC elliptical cavities which are designed with geometrical beta 0.63 and 0.82. In this paper, the 650 MHz β=0.63 SC elliptical cavity is studied, including cavity optimization, multipacting, high order modes (HOMs) and generator RF power calculation. Supported by National Natural Science Foundation of China (91426303)

  2. Double diffusion in arbitrary porous cavity: Part II

    Science.gov (United States)

    Ahamad, N. Ameer; Kamangar, Sarfaraz; Salman Ahmed N., J.; Soudagar, Manzoor Elahi M.; Khan, T. M. Yunus

    2017-07-01

    Heat and mass transfer in porous medium is one of the fundamental topics of interest. The present article is dedicated to study the effect of a small block placed at center of left vertical surface of the cavity. The block is maintained at isothermal temperature That three of its edges attached with porous medium. The left surface of cavity is maintained at highest concentration and right surface at lowest concentration. The right surface of cavity is at cold isothermal temperature Tc. Governing equations are converted into matrix form of equations with the help of finite element method and solved iteratively by using a computer code generated in MATLAB.

  3. Electromagnetic Wave Chaos in Gradient Refractive Index Optical Cavities

    International Nuclear Information System (INIS)

    Wilkinson, P. B.; Fromhold, T. M.; Taylor, R. P.; Micolich, A. P.

    2001-01-01

    Electromagnetic wave chaos is investigated using two-dimensional optical cavities formed in a cylindrical gradient refractive index lens with reflective surfaces. When the planar ends of the lens are cut at an angle to its axis, the geometrical ray paths are chaotic. In this regime, the electromagnetic mode spectrum of the cavity is modulated by both real and ghost periodic ray paths, which also 'scar' the electric field intensity distributions of many modes. When the cavity is coupled to waveguides, the eigenmodes generate complex series of resonant peaks in the electromagnetic transmission spectrum

  4. Heat and mass transfer in porous cavity: Assisting flow

    Energy Technology Data Exchange (ETDEWEB)

    Badruddin, Irfan Anjum [Dept. of Mechanical Engineering, University of Malaya, Kuala Lumpur, 50603 (Malaysia); Quadir, G. A. [School of Mechatronic Engineering, University Malaysia Perlis, Pauh Putra, 02600 Arau, Perlis (Malaysia)

    2016-06-08

    In this paper, investigation of heat and mass transfer in a porous cavity is carried out. The governing partial differential equations are non-dimensionalised and solved using finite element method. The left vertical surface of the cavity is maintained at constant temperature and concentration which are higher than the ambient temperature and concentration applied at right vertical surface. The top and bottom walls of the cavity are adiabatic. Heat transfer is assumed to take place by natural convection and radiation. The investigation is carried out for assisting flow when buoyancy and gravity force act in same direction.

  5. Nonreciprocal lasing in topological cavities of arbitrary geometries

    Science.gov (United States)

    Bahari, Babak; Ndao, Abdoulaye; Vallini, Felipe; El Amili, Abdelkrim; Fainman, Yeshaiahu; Kanté, Boubacar

    2017-11-01

    Resonant cavities are essential building blocks governing many wave-based phenomena, but their geometry and reciprocity fundamentally limit the integration of optical devices. We report, at telecommunication wavelengths, geometry-independent and integrated nonreciprocal topological cavities that couple stimulated emission from one-way photonic edge states to a selected waveguide output with an isolation ratio in excess of 10 decibels. Nonreciprocity originates from unidirectional edge states at the boundary between photonic structures with distinct topological invariants. Our experimental demonstration of lasing from topological cavities provides the opportunity to develop complex topological circuitry of arbitrary geometries for the integrated and robust generation and transport of photons in classical and quantum regimes.

  6. Design of the Advanced Virgo non-degenerate recycling cavities

    International Nuclear Information System (INIS)

    Granata, M; Barsuglia, M; Flaminio, R; Freise, A; Hild, S; Marque, J

    2010-01-01

    Advanced Virgo is the project to upgrade the interferometric gravitational wave detector Virgo, and it foresees the implementation of power and signal non-degenerate recycling cavities. Such cavities suppress the build-up of high order modes of the resonating sidebands, with some advantage for the commissioning of the detector and the build-up of the gravitational signal. Here we present the baseline design of the Advanced Virgo non-degenerate recycling cavities, giving some preliminary results of simulations about the tolerances of this design to astigmatism, mirror figure errors and thermal lensing.

  7. Design and Performance of the LCLS Cavity BPM System

    Energy Technology Data Exchange (ETDEWEB)

    Lill, R.M.; Morrison, L.H.; Norum, W.E.; Sereno, N.; Waldschmidt, G.J.; Walters, D.R.; /Argonne; Smith, S.; Straumann, T.; /SLAC

    2008-01-23

    In this paper we present the design of the beam position monitor (BPM) system for the LCLS undulator, which features a high-resolution X-band cavity BPM. Each BPM has a TM{sub 010} monopole reference cavity and a TM{sub 110} dipole cavity designed to operate at a center frequency of 11.384 GHz. The signal processing electronics features a low noise single-stage three-channel heterodyne receiver that has selectable gain and a phase locking local oscillator. We will discuss the system specifications, design, and prototype test results.

  8. Design and performance of the LCLS cavity BPM system.

    Energy Technology Data Exchange (ETDEWEB)

    Lill, R.; Norum, E.; Morrison, L.; Sereno, N.; Waldschmidt, G.; Walters, D.; Smith, S.; Straumann, T.; SLAC

    2008-01-01

    In this paper we present the design of the beam position monitor (BPM) system for the LCLS undulator, which features a high-resolution X-band cavity BPM. Each BPM has a TM{sub 010} monopole reference cavity and a TM{sub 110} dipole cavity designed to operate at a center frequency of 11.384 GHz. The signal processing electronics features a low- noise single-stage three-channel heterodyne receiver that has selectable gain and a phase locking local oscillator. We will discuss the system specifications, design, and prototype test results.

  9. Design and Performance of the LCLS Cavity BPM System

    International Nuclear Information System (INIS)

    Lill, R.M.; Morrison, L.H.; Norum, W.E.; Sereno, N.; Waldschmidt, G.J.; Walters, D.R.; Argonne; Smith, S.; Straumann, T.

    2008-01-01

    In this paper we present the design of the beam position monitor (BPM) system for the LCLS undulator, which features a high-resolution X-band cavity BPM. Each BPM has a TM 010 monopole reference cavity and a TM 110 dipole cavity designed to operate at a center frequency of 11.384 GHz. The signal processing electronics features a low noise single-stage three-channel heterodyne receiver that has selectable gain and a phase locking local oscillator. We will discuss the system specifications, design, and prototype test results

  10. Design and performance of the LCLS cavity BPM system

    International Nuclear Information System (INIS)

    Lill, R.; Norum, E.; Morrison, L.; Sereno, N.; Waldschmidt, G.; Walters, D.; Smith, S.; Straumann, T.

    2008-01-01

    In this paper we present the design of the beam position monitor (BPM) system for the LCLS undulator, which features a high-resolution X-band cavity BPM. Each BPM has a TM 010 monopole reference cavity and a TM 110 dipole cavity designed to operate at a center frequency of 11.384 GHz. The signal processing electronics features a low- noise single-stage three-channel heterodyne receiver that has selectable gain and a phase locking local oscillator. We will discuss the system specifications, design, and prototype test results.

  11. Early prototype of a superconducting RF cavity for LEP

    CERN Multimedia

    CERN PhotoLab

    1979-01-01

    As early as 1979, before LEP became an approved project, studies were located in the ISR Division. Although Cu-cavities were foreseen, certainly for the 1st energy-stage, superconducting cavities were explored as a possible alternative for the 2nd energy-stage. This began with very basic studies of manufacture and properties of Nb-cavities. This one, held by Mr.Girel, was made from bulk Nb-sheet, 2.5 mm thick. It was dimensioned for tests at 500 MHz (LEP accelerating RF was 352.2 MHz). See also 8004204, 8007354, 8209255, 8210054, 8312339.

  12. Cavity enhanced interference of orthogonal modes in a birefringent medium

    Science.gov (United States)

    Kolluru, Kiran; Saha, Sudipta; Gupta, S. Dutta

    2018-03-01

    Interference of orthogonal modes in a birefringent crystal mediated by a rotator is known to lead to interesting physical effects (Solli et al., 2003). In this paper we show that additional feedback offered by a Fabry-Perot cavity (containing the birefringent crystal and the rotator) can lead to a novel strong interaction regime. Usual signatures of the strong interaction regime like the normal mode splitting and avoided crossings, sensitive to the rotator orientation, are reported. A high finesse cavity is shown to offer an optical setup for measuring small angles. The results are based on direct calculations of the cavity transmissions along with an analysis of its dispersion relation.

  13. Modeling resonant cavities for single-photon waveguide sources

    International Nuclear Information System (INIS)

    Evans, Philip G.; Bennink, Ryan S.; Grice, Warren P.

    2008-01-01

    Spectral correlations between photon pairs generated by spontaneous parametric down conversion (SPDC) in bulk non-linear optical crystals remain a hindrance to the implementation of efficient quantum communication architectures. It has been demonstrated that SPDC within a distributed micro-cavity can result in little or no correlation between photon pairs. We present results on modeling three different cavity configurations based on integrated Bragg gratings. Output from the SPDC process can be tailored by altering the periodicity and geometry of such nanostructures. We will discuss the merits of each cavity configuration from the standpoint of degenerate Type-II SPDC

  14. Spatial field configuration in a cavity with nonresonant feedback

    Energy Technology Data Exchange (ETDEWEB)

    Belonuchkin, V.E.; Eskin, N.I.; Kozel, S.M.; Kuznetsov, E.P.; Lokshin, G.R.

    1978-03-01

    An investigation is made of the spatial characteristics of the field in a cavity one of whose mirrors is replaced by a diffuse reflector with a ''wide'' scattering indicatrix. A derivation is given of a system of integral equations for the determination of the field correlation function in the cavity and its approximate solution is given. It is shown that the nature of the field correlation function is established after the first reflection: subsequent reflections simply result in small corrections. An estimate is obtained of the field correlation radius in the cavity.

  15. Use of next-generation sequencing in oral cavity cancer

    DEFF Research Database (Denmark)

    Tabatabaeifar, Siavosh; Kruse, Torben A; Thomassen, Mads

    of tumour cells exists. Conclusions: Use of next generation sequencing in oral cavity cancer can give valuable insight into the biology of the disease. By investigating intra tumour heterogeneity we see that the different tumour specimens in each patient are quite homogenous, but evidence of heterogeneous......Background: Oral cavity cancer is a subgroup of head and neck cancer which is the world’s 6th most common cancer form. Oral squamous cell carcinomas (OSCC) constitute almost all oral cavity cancers, and OSCC are primarily attributed by excessive alcohol consumption and tobacco exposure...

  16. Moderate and deep nurse-administered propofol sedation is safe

    DEFF Research Database (Denmark)

    Jensen, Jeppe Thue; Møller, Ann; Hornslet, Pernille

    2015-01-01

    INTRODUCTION: Non-anaesthesiologist-administered propofol sedation (NAPS/NAAP) is increasingly used in many countries. Most regimens aim for light or moderate sedation. Little evidence on safety of deep NAPS sedation is available. The aim of this study was to explore the safety of intermittent deep...... sedation with NAPS in patients undergoing gastroenterologic endoscopic procedures. METHODS: This was a retrospective case-control study. All patients sedated with NAPS for colonoscopies, sigmoidoscopies and oesophagogastroduodenoscopies from May 2007 through December 2012 were included. Cases were defined...... with a higher rate of adverse events. CONCLUSION: Safety during intermittent deep sedation with NAPS was good. Age, ASA class 3 and total propofol dose were correlated with a higher rate of adverse events. Patients aged 60 years or more needed more handling during adverse events. FUNDING: Arvid Nilsson...

  17. Administering truncated receive functions in a parallel messaging interface

    Science.gov (United States)

    Archer, Charles J; Blocksome, Michael A; Ratterman, Joseph D; Smith, Brian E

    2014-12-09

    Administering truncated receive functions in a parallel messaging interface (`PMI`) of a parallel computer comprising a plurality of compute nodes coupled for data communications through the PMI and through a data communications network, including: sending, through the PMI on a source compute node, a quantity of data from the source compute node to a destination compute node; specifying, by an application on the destination compute node, a portion of the quantity of data to be received by the application on the destination compute node and a portion of the quantity of data to be discarded; receiving, by the PMI on the destination compute node, all of the quantity of data; providing, by the PMI on the destination compute node to the application on the destination compute node, only the portion of the quantity of data to be received by the application; and discarding, by the PMI on the destination compute node, the portion of the quantity of data to be discarded.

  18. Moderate and deep nurse-administered propofol sedation is safe

    DEFF Research Database (Denmark)

    Jensen, Jeppe Thue; Møller, Ann; Hornslet, Pernille

    2015-01-01

    sedation with NAPS in patients undergoing gastroenterologic endoscopic procedures. METHODS: This was a retrospective case-control study. All patients sedated with NAPS for colonoscopies, sigmoidoscopies and oesophagogastroduodenoscopies from May 2007 through December 2012 were included. Cases were defined......INTRODUCTION: Non-anaesthesiologist-administered propofol sedation (NAPS/NAAP) is increasingly used in many countries. Most regimens aim for light or moderate sedation. Little evidence on safety of deep NAPS sedation is available. The aim of this study was to explore the safety of intermittent deep......'s Foundation provided funding for this study. The founders did not have any influence on the design or the presentation of the study. TRIAL REGISTRATION: not relevant....

  19. Haematological disorders in Thorotrast-administered patients in Japan

    International Nuclear Information System (INIS)

    Kamiyama, Ryuichi; Hatakeyama, Shigeru

    1989-01-01

    Fifteen haematological disorders including ten leukaemia cases, one primary acquired sideroblastic anaemia and four aplastic anaemia cases were studied clinicopathologically in autopsies from patients who had been administered Thorotrast in Japan. The leukaemia group, the primary acquired sideroblastic anaemia and the aplastic anaemia cases after Thorotrast administration were considered to be mainly atypical, and it was speculated that damage induced by Thorotrast may affect the haemopoietic stem cell level and the haemopoietic microenvironment. Both dose rate and absorbed dose estimated in bone marrow, spleen and liver at autopsy showed no significant difference between the leukaemia group, primary acquired sideroblastic anaemia, aplastic anaemia and non-haematological disorders excluding the malignant hepatic tumours and liver cirrhosis. (author)

  20. Techniques to administer oral, inhalational, and IV sedation in dentistry

    Directory of Open Access Journals (Sweden)

    Diana Krystyna Harbuz

    2016-02-01

    Full Text Available Background Sedation in dentistry is a controversial topic given the variety of opinions regarding its safe practice. Aims This article evaluates the various techniques used to administer sedation in dentistry and specific methods practiced to form a recommendation for clinicians. Methods An extensive literature search was performed using PubMed, Medline, Google Scholar, Google, and local library resources. Results Most of the literature revealed a consensus that light sedation on low-risk American Society of Anesthesiologists (ASA groups, that is ASA I, and possibly II, is the safest method for sedation in a dental outpatient setting. Conclusion Formal training is essential to achieve the safe practice of sedation in dentistry or medicine. The appropriate setting for sedation should be determined as there is an increased risk outside the hospital setting. Patients should be adequately assessed and medication titrated appropriately, based on individual requirements.