  1. Indications for needle catheter jejunostomy in elective abdominal surgery.

    Science.gov (United States)

    Heberer, M; Bodoky, A; Iwatschenko, P; Harder, F

    1987-06-01

    Needle catheter jejunostomy for postoperative nutritional support is now employed worldwide. However, there is a large discrepancy regarding indications for this technique which this study attempts to rectify. The need for nutritional support after elective abdominal procedures in 464 patients was analyzed and compared with the experience with needle catheter jejunostomy in 42 patients. The results show that needle catheter jejunostomy is indicated after extensive operations of the upper gastrointestinal tract, for example, esophagectomy, total gastrectomy, and the Whipple procedure. With minor upper gastrointestinal operations, or procedures of the lower gastrointestinal tract, needle catheter jejunostomy should be performed only in patients with poor nutritional status or in the presence of postoperative chemotherapy or radiotherapy. In an unclear situation, liberal insertion of the needle catheter jejunostomy and a postponed decision on enteral feeding is recommended, as there is no significant catheter-related morbidity. PMID:3109269

  2. Hollow needle cataract aspiration in antiquity.

    Science.gov (United States)

    Pérez-Cambrodí, Rafael J; Ascaso, Francisco J; Diab, Fathi; Alzamora-Rodríguez, Antonio; Grzybowski, Andrzej

    2015-12-01

    The dislocation of the crystalline lens or couching technique was the predominant procedure to surgically remove cataracts until the 18th century A.D. However, in the Middle Ages, some Arab physicians tried to aspirate the opaque lens by means of a glass tube following a paracentesis. Some literary sources attributed the origins of this technique to Antyllus of Alexandria, a Greek surgeon who lived in the 2nd century A.D. in the Roman Empire. Nevertheless, this statement remains unclear and is probably the consequence of posterior interpretations or incorrect translations of the manuscripts. In recent years, the discovery of the hollow needles from Montbellet (France) and Viladamat (Spain), in archaeological settlements dated between the 1st century and 3rd century A.D., has reopened the possibility of cataract extraction as an option in the surgical management of soft cataracts in the antiquity. In any case, these findings are exceptional, and thus, probably this technique was not widely practised and very likely disparaged by the medical community. PMID:26385516

  3. Silica needle template fabrication of metal hollow microneedle arrays

    International Nuclear Information System (INIS)

    Drug delivery through hollow microneedle (HMN) arrays has now been recognized as one of the most promising techniques because it minimizes the shortcomings of the traditional drug delivery methods and has many exciting advantages—pain free and tunable release rates, for example. However, this drug delivery method has been hindered greatly from mass clinical application because of the high fabrication cost of HMN arrays. Hence, we developed a simple and cost-effective procedure using silica needles as templates to massively fabricate HMN arrays by using popular materials and industrially applicable processes of micro- imprint, hot embossing, electroplating and polishing. Metal HMN arrays with high quality are prepared with great flexibility with tunable parameters of area, length of needle, size of hollow and array dimension. This efficient and cost-effective fabrication method can also be applied to other applications after minor alterations, such as preparation of optic, acoustic and solar harvesting materials and devices

  4. Needle catheter jejunostomy: a controlled, prospective, randomized trial in patients with gynecologic malignancy.

    Science.gov (United States)

    Spirtos, N M; Ballon, S C

    1988-06-01

    Sixty patients with gynecologic cancer entered a prospective, randomized study of immediate postoperative feeding. Thirty-three women in the study group received an elemental diet (Vivonex HN) delivered through a needle catheter jejunostomy. Twenty-seven patients in the control group were given standard 5% dextrose and electrolyte solutions. Patients in both groups were stratified according to nutritional status as determined by anthropometric evaluation and levels of serum albumin, total protein, and transferrin. These parameters also were measured at intervals throughout the study. Only one catheter-related complication occurred. Patients in the study group received significantly more calories (p = 0.01) and were better able to maintain serum levels of transferrin (p = 0.05) than those in the control group. An elemental diet administered through the needle catheter jejunostomy effectively maintains postoperative nutrition and is associated with few complications. PMID:3132853

  5. Ozone production of hollow-needle-to-mesh negative corona discharge enhanced by dielectric tube on the needle electrode

    International Nuclear Information System (INIS)

    For the hollow-needle-to-mesh negative corona discharge in air, we studied the effect of placing the dielectric tube on the needle electrode and the effect of various positions of the end of this tube with respect to the tip of the needle electrode on the concentration of ozone produced by the discharge, the ozone production yield and the discharge V–A characteristics. We found that the placement of the dielectric tube on the needle electrode with a suitable position of this tube end with respect to the tip of the needle electrode for a particular discharge power led to a more than fourfold increase in the concentration of ozone produced by the discharge and also, for a constant airflow, the ozone production yield. (fast track communication)

  6. Ozone generation from two hollow needles to plate electrical discharges enhanced by an airflow

    OpenAIRE

    Pekárek, Stanislav; Rosenkranz, Josef; Khun, Josef

    2004-01-01

    The efficient ozone generation plays an important role from the standpoint of many applications. Most of the ozone produced is with the help of electrical discharges, e.g. DC, AC or pulse corona discharge or dielectric barrier discharge. In this paper we studied ozone generation by two hollow needles to plate DC electrical discharge enhanced by the airflow through the needle electrodes. We present the results concerning production of ozone versus discharge current for the discharge between on...

  7. Needle localization using a moving stylet/catheter in ultrasound-guided regional anesthesia: a feasibility study

    Science.gov (United States)

    Beigi, Parmida; Rohling, Robert

    2014-03-01

    Despite the wide range and long history of ultrasound guided needle insertions, an unresolved issue in many cases is clear needle visibility. A well-known ad hoc technique to detect the needle is to move the stylet and look for changes in the needle appearance. We present a new method to automatically locate a moving stylet/catheter within a stationary cannula using motion detection. We then use this information to detect the needle trajectory and the tip. The differences between the current frame and the previous frame are detected and localized, to minimize the influence of tissue global motions. A polynomial fit based on the detected needle axis determines the estimated stylet shaft trajectory, and the extent of the differences along the needle axis represents the tip. Over a few periodic movements of the stylet including its full insertion into the cannula to the tip, a combination of polynomial fits determines the needle trajectory and the last detected point represents the needle tip. Experiments are conducted in water bath and bovine muscle tissue for several stylet/catheter materials. Results show that a plastic stylet has the best needle shaft and tip localization accuracy in the water bath with RMSE = 0:16 mm and RMSE = 0:51 mm, respectively. In the bovine tissue, the needle tip was best localized with the plastic catheter with RMSE = 0:33 mm. The stylet tip localization was most accurate with the steel stylet, with RMSE = 2:81 mm and the shaft was best localized with the plastic catheter, with RMSE = 0:32 mm.

  8. Transconjunctival sutureless intrascleral intraocular lens fixation using intrascleral tunnels guided with catheter and 30-gauge needles.

    Science.gov (United States)

    Takayama, Kohei; Akimoto, Masayuki; Taguchi, Hogara; Nakagawa, Satoko; Hiroi, Kano

    2015-11-01

    We invented a new method for fixing an intraocular lens (IOL) in the scleral tunnel without using a wide conjunctival incision. Modified bent catheter needles were used to penetrate the IOL haptics through the sclerotomy sites. The IOL haptics were inserted into 30-guage (G) scleral tunnels guided by double 30-G needles piercing the sclera. All procedures were performed through the conjunctiva without wide incision. The procedure does not require special forceps, trocars or fibrin glue, only catheter and 30-G needles. The aid of an assistant was not required to support the IOL haptic. The procedures were easily learnt based on our previous method. As with other transconjunctival sutureless surgeries, patients feel less discomfort and the conjunctiva can be conserved for future glaucoma surgery. Complications included two cases of vitreous haemorrhage (16.7%), and one case each of postoperative hypotony, and iris capture (8.3%). Astigmatism induced by intraocular aberration was the same as we reported previously. Our method for fixing the IOL into the scleral tunnel is innovative, less expensive, less invasive and quick. This modified method is a good alternative for fixing IOL haptics into the sclera. PMID:25855502

  9. Relationship between rotational temperature and energy density in atmospheric pressure hollow-needle to plate electrical discharge

    Czech Academy of Sciences Publication Activity Database

    Pekárek, S.; Šimek, Milan

    2004-01-01

    Roč. 49, č. 5 (2004), s. 66. ISSN 0003-0503. [Annual Gaseous Electronics Conference /57./. Bunratty, 26.09.2004-29.09.2004] R&D Projects: GA AV ČR IAA1043403 Institutional research plan: CEZ:AV0Z2043910 Keywords : hollow needle to plate discharge, rotational temperature, vibrational distribution Subject RIV: BL - Plasma and Gas Discharge Physics

  10. The Wiley Spinal Catheter-Over-Needle System for Continuous Spinal Anesthesia: A Case Series of 5 Cesarean Deliveries Complicated by Paresthesias and Headaches.

    Science.gov (United States)

    McKenzie, Christine P; Carvalho, Brendan; Riley, Edward T

    2016-01-01

    Intrathecal catheter devices using a catheter-over-needle design and softer flexible material have been introduced to clinical practice with the aim of reducing some of the complications such as postdural puncture headaches and paresthesias seen with previous versions of intrathecal catheters. We present a case series of 5 cesarean deliveries using the Wiley Spinal intrathecal system (Epimed, Johnstown, New York), which was recently approved by the US Food and Drug Administration. The intrathecal catheter system consists of a flexible 23-gauge intrathecal cannula over a 27-gauge pencil-point spinal needle. The placement of the intrathecal catheter was successful in all 5 cases; however, paresthesias in 3 cases and postdural puncture headaches in 2 cases complicated the placement and use of the device. Although the unique catheter-over-needle design facilitates the use of smaller-gauge spinal needles for dural puncture and larger-gauge catheters for medication administration, this case series using the Wiley Spinal suggests that paresthesias and postdural puncture headaches may still limit its widespread utilization. Future studies are needed to determine the true incidence of complications and to determine the role of continuous spinal anesthesia in the obstetric population. PMID:26909488

  11. Needle and catheter navigation using electromagnetic tracking for computer-assisted C-arm CT interventions

    Science.gov (United States)

    Nagel, Markus; Hoheisel, Martin; Petzold, Ralf; Kalender, Willi A.; Krause, Ulrich H. W.

    2007-03-01

    Integrated solutions for navigation systems with CT, MR or US systems become more and more popular for medical products. Such solutions improve the medical workflow, reduce hardware, space and costs requirements. The purpose of our project was to develop a new electromagnetic navigation system for interventional radiology which is integrated into C-arm CT systems. The application is focused on minimally invasive percutaneous interventions performed under local anaesthesia. Together with a vacuum-based patient immobilization device and newly developed navigation tools (needles, panels) we developed a safe and fully automatic navigation system. The radiologist can directly start with navigated interventions after loading images without any prior user interaction. The complete system is adapted to the requirements of the radiologist and to the clinical workflow. For evaluation of the navigation system we performed different phantom studies and achieved an average accuracy of better than 2.0 mm.

  12. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P;

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  13. A Novel Fenestration Technique for Abdominal Aortic Dissection Membranes Using a Combination of a Needle Re-entry Catheter and the “Cheese-wire” Technique

    International Nuclear Information System (INIS)

    Purpose: This study was designed to demonstrate the applicability of a combined needle-based re-entry catheter and “cheese-wire” technique for fenestration of abdominal aortic dissection membranes. Methods: Four male patients (mean age: 65 years) with acute complicated aortic type B dissections were treated at our institution by fenestrating the abdominal aortic dissection membrane using a hybrid technique. This technique combined an initial membrane puncture with a needle-based re-entry catheter using a transfemoral approach. A guidewire was passed through the re-entry catheter and across the membrane. Using a contralateral transfemoral access, this guidewire was then snared, creating a through-and-through wire access. The membrane was then fenestrated using the cheese-wire maneuver. Results: We successfully performed: (a) membrane puncture; (b) guidewire passage; (c) guidewire snaring; and (d) cheese-wire maneuver in all four cases. After this maneuver, decompression of the false lumen and acceptable arterial inflow into the true lumen was observed in all cases. The dependent visceral arteries were reperfused. In one case, portions of the fenestrated membrane occluded the common iliac artery, which was immediately and successfully stented. In another case, long-standing intestinal hypoperfusion before the fenestration resulted in reperfusion-related shock and intraoperative death of the patient. Conclusions: The described hybrid approach for fenestration of dissection membranes is technically feasible and may be established as a therapeutic method in cases with a complicated type B dissection.

  14. [Catheter jejunostomy in elective abdominal surgery].

    Science.gov (United States)

    Bodoky, A; Heberer, M; Iwatschenko, P; Harder, F

    1985-10-01

    Needle catheter jejunostomy is used to a varying extent today. Therefore, the need for nutritional support was evaluated following elective abdominal surgery and compared to experiences with postoperative enteral feeding. Oesophagectomy, total gastrectomy and the Whipple procedure were identified as good indications for catheter jejunostomy, whereas with other types of operation an individual decision is required. PMID:3935397

  15. Substituição da agulha isolada para eletroneuroestimulação pela agulha metálica de cateter intravenoso, na verificação da punção epidural, em cães Replacement of an insulated electric neurostimulation spinal needle with an intravenous catheter metal needle to confirm correct epidural puncture in dogs

    Directory of Open Access Journals (Sweden)

    E.A. Tudury

    2013-02-01

    Full Text Available Utilizou-se o eletroneuroestimulador como um meio adequado para confirmação do posicionamento da ponta de agulhas isoladas no espaço epidural lombossal, por meio de pequenas estimulações elétricas que provocam contrações dos músculos inervados, empregando-se agulha de cateter intravenoso em vez de agulha isolada para a eletroneuroestimulação. Foram utilizados 40 cães para procedimentos cirúrgicos ortopédicos, abdominais ou retroumbilicais que necessitassem de bloqueio epidural. Durante a introdução gradativa da agulha no canal vertebral lombossacral, estímulos elétricos de 1,5 a 0,5mA foram aplicados. Diante de contrações musculares em membros pélvicos, cauda e/ou ânus, as quais foram consideradas respostas condizentes com o correto posicionamento da agulha no espaço epidural, estimulando raízes da cauda equina, procedeu-se à administração da associação de lidocaína, bupivacaína e tramadol. Constatou-se a adequada anestesia epidural mediante relaxamento do esfíncter anal, ausência dos reflexos patelares e flexor e a analgesia na área cirúrgica abdominal. Conclui-se que o método foi eficaz para a confirmação do correto posicionamento da agulha no espaço epidural durante a realização dessa anestesia regional em cães.The electric neurostimulator was used as an adequate mean for the confirmation of the correct placement of the tip of the insulated needles in the lumbosacral epidural space through small electric stimulations causing muscle contractions by using an intravenous catheter needle instead of an electric neurostimulation insulated needle. Forty dogs were selected based on the need for an epidural block for orthopedic, abdominal or retroumbilical surgical procedures. Electrical stimuli were applied from 1.5 to 0.5mA during a gradual introduction of the needle into the lumbosacral vertebral canal. Responses that were considered as indicative of the correct placement of the needle and stimulation of

  16. Haemolyzed samples: responsibility of short catheters.

    Science.gov (United States)

    Raisky, F; Gauthier, C; Marchal, A; Blum, D

    1994-01-01

    The haemolysis of blood samples is a source of error in the electrolytic and enzymatic determination in clinical biochemistry. This circumstance seems dependent on the material used for the venepuncture. In this study we compared three kinds of material in 350 patients who were sampled in the emergency department. This randomized study compared the haemolysis of blood samples collected with stainless steel needles and short catheters, either Teflon FEP (Cathlon Critikon) or polyurethane Vialon (Insyte Becton-Dickinson). Quantification of hemolysis was performed by assay of the optical density of plasma haemoglobin. Results were analysed, after verification of the randomization, by one-way analysis of variance by ranks. This study demonstrated a highly significant relation between occurrence of haemolysis and the sampling material, used according to its technical obligations. Haemolysis occurred frequently when short catheters were used in 42% and 55% of cases with the Teflon and Vialon catheters, respectively. Haemolysis was much less frequent with stainless steel needles (12%). This difference was even more marked for haemoglobin levels above 1.5 milligrams of plasma, where the incidence was 4.2%, 9% and 30%, respectively, for the stainless steel needles, the Teflon catheter and the Vialon catheter. This study induced our emergency department to take more blood samples with a needle, even if an infusion was to be given subsequently, or to take them using a Teflon catheter. PMID:7840428

  17. Needles and Other Sharps (Safe Disposal Outside of Health Care Settings)

    Science.gov (United States)

    ... arthritis, cancer, diabetes, hepatitis, HIV/AIDS, infertility, migraines, multiple sclerosis, osteoporosis, blood clotting disorders, and psoriasis. Examples of sharps include: Needleshollow needles used to inject drugs (medication) under the skin Syringes – devices used to inject ...

  18. Nonoperative replacement of a jejunostomy feeding catheter.

    Science.gov (United States)

    Stogdill, B J; Page, C P; Pestana, C

    1984-02-01

    Nonoperative replacement of lost or occluded jejunal feeding catheters proved successful in 8 of 11 patients. This technique is recommended as a nonoperative means of replacing a needle catheter jejunostomy when it is accidentally lost or becomes occluded. Adherence to sterile technique and gentle advancement of the guide wire to avoid injury to the bowel are important. Since the technique depends on an established tract between the skin and the bowel, catheter replacement should not be attempted when the feeding catheter is lost or becomes occluded in the immediate postoperative period. In addition, confirmation of catheter patency and intraluminal position with sterile water-soluble contrast medium is critical to the safe use of this technique. PMID:6421183

  19. Interventional radiological imaging and treatment of port catheter dysfunctions

    International Nuclear Information System (INIS)

    To evaluate the impact of interventional radiological imaging and treatment of central venous port catheter complications. Materials and Methods: In this retrospective analysis 429 port catheter dysfunctions were evaluated in 393 port catheter systems for a total of 389 patients over a period of 10 years. The study included 193 (49.1 %) patients with radiologically implanted port catheter systems and 200 (50.9 %) referred patients with surgically implanted port systems. Port catheter dysfunctions were subdivided into early and late complications as well as into non-thrombotic and thrombotic events. After administration of contrast medium, the port system was visualized using digital subtraction angiography. Data were retrospectively collected from the in-house databases and then analyzed descriptively. Results: 429 contrast media injections via port catheters were performed in 393 port catheter systems. There were 359 (83.7 %) late complications and 70 (16.3 %) early complications. In 299 (69.7 %) cases thrombotic events occurred and 130 (30.3 %) non-thrombotic events were recorded. The most common reason for contrast media injection via port catheter system was port catheter-related thrombosis in 269 (62.7 %) cases. 70 (16.3 %) catheter migrations and 30 (7.0 %) fibrin sheath formations were detected. 18 (4.2 %) port needle malfunctions could be resolved through needle exchange. All 15 (3.5 %) catheter disconnections had to be revised in all cases. Also six port explantations were performed in 6 (1.4 %) catheter fractures. Conclusion: The possibilities of angiographic imaging and interventional radiological correction of port catheter dysfunctions must be exploited fully in order to avoid premature port explantation. (orig.)

  20. Sci—Fri PM: Topics — 08: The Role and Benefits of Electromagnetic Needle-Tracking Technologies in Brachytherapy

    International Nuclear Information System (INIS)

    In modern brachytherapy, application of large doses of ionizing radiation in a limited number of fractions is frequent. Furthermore, as with any surgical procedures, brachytherapy is subject to learning curve effects. In this context, there could be advantages of integrating real-time tracking of needles/catheters to existing protocols given the recent prominent advances in tracking technologies. In this work, we review the use of an electromagnetic tracking system (EMTS) based on the second generation Aurora® Planar Field Generator (Northern Digital Inc) and custom design needles (Philips Healthcare) for brachytherapy applications. The position and orientation information is obtained from 5 degrees of freedom sensors. Basic system performance characterization is performed in well-controlled conditions to establish accuracy and reproducibility as well as potential interference from standard brachytherapy equipment. The results show that sensor locations can be tracked to within 0.04mm (la) when located within 26cm of the generator. Orientation accuracy of the needle remained within ±1° in the same region, but rose quickly at larger distances. The errors on position and orientation strongly dependent the sensor position in the characterization volume (500×500×500mm3). The presence of an ultrasound probe was shown to have negligible effects on tracking accuracy. The use of EMTS for automatic catheter/applicator reconstruction was also explored. Reconstruction time was less than 10 sec/channel and tips identification was within 0.69±0.29mm of the reference values. Finally, we demonstrate that hollow needle designs with special EM adaptation also allow for real-time seed drop position estimation. In phantom experiments showed that drop positions were on average within 1.6±0.9mm of the reference position measured from μCT. Altogether, EMTS offer promising benefits in a wide range of brachytherapy applications

  1. Sci—Fri PM: Topics — 08: The Role and Benefits of Electromagnetic Needle-Tracking Technologies in Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Beaulieu, L.; Racine, E.; Boutaleb, S.; Filion, O. [Département de Radio-Oncologie et Centre de Recherche du CHU de Québec, CHU de Québec, Québec (Québec), and Département de Physique, de Génie Physique et d' Optique et Centre de recherche en sur le Cancer, Université Laval, Québec (Québec) (Canada); Poulin, E.; Hautvast, G. [Biomedical Systems, Philips Group Innovation, High Tech Campus 34 (HTC 34), Eindhoven (Netherlands); Binnekamp, D. [Integrated Clinical Solutions and Marketing, Philips Healthcare, Veenpluis 4-6, Best (Netherlands)

    2014-08-15

    In modern brachytherapy, application of large doses of ionizing radiation in a limited number of fractions is frequent. Furthermore, as with any surgical procedures, brachytherapy is subject to learning curve effects. In this context, there could be advantages of integrating real-time tracking of needles/catheters to existing protocols given the recent prominent advances in tracking technologies. In this work, we review the use of an electromagnetic tracking system (EMTS) based on the second generation Aurora® Planar Field Generator (Northern Digital Inc) and custom design needles (Philips Healthcare) for brachytherapy applications. The position and orientation information is obtained from 5 degrees of freedom sensors. Basic system performance characterization is performed in well-controlled conditions to establish accuracy and reproducibility as well as potential interference from standard brachytherapy equipment. The results show that sensor locations can be tracked to within 0.04mm (la) when located within 26cm of the generator. Orientation accuracy of the needle remained within ±1° in the same region, but rose quickly at larger distances. The errors on position and orientation strongly dependent the sensor position in the characterization volume (500×500×500mm{sup 3}). The presence of an ultrasound probe was shown to have negligible effects on tracking accuracy. The use of EMTS for automatic catheter/applicator reconstruction was also explored. Reconstruction time was less than 10 sec/channel and tips identification was within 0.69±0.29mm of the reference values. Finally, we demonstrate that hollow needle designs with special EM adaptation also allow for real-time seed drop position estimation. In phantom experiments showed that drop positions were on average within 1.6±0.9mm of the reference position measured from μCT. Altogether, EMTS offer promising benefits in a wide range of brachytherapy applications.

  2. Technique of Peritoneal Catheter Placement under Fluoroscopic Guidance

    International Nuclear Information System (INIS)

    Peritoneal catheters are mainly used for peritoneal dialysis in patients with end-stage renal disease. Other uses of this catheter include intraperitoneal chemotherapy and gene therapy for ovarian cancer and draining of uncontrolled refractory ascites in patients with liver cirrhosis. Traditionally, surgeons place most of these peritoneal catheters either by laparoscopy or open laparotomy. We detail our percutaneous approach to placing peritoneal catheters using fluoroscopic guidance. We emphasize the use of additional ultrasound guidance, including gray scale and color Doppler ultrasound, to determine the safest puncture site and to guide the initial needle puncture in order to avoid bowel perforation and injury to epigastric artery. We present our experience in placing peritoneal catheters using this technique in 95 patients with various indications. Fluoroscopic guided percutaneous placement of peritoneal catheters is a safe, minimally invasive, and effective alternative to open surgical or laparoscopic placement.

  3. Needle Thoracotomy in Trauma.

    Science.gov (United States)

    Rottenstreich, Misgav; Fay, Shmuel; Gendler, Sami; Klein, Yoram; Arkovitz, Marc; Rottenstreich, Amihai

    2015-12-01

    Tension pneumothorax is one of the leading causes of preventable death in trauma patients. Needle thoracotomy (NT) is the currently accepted first-line intervention but has not been well validated. In this review, we have critically discussed the evidence for NT procedure, re-examined the recommendations by the Advanced Trauma Life Support organization and investigated the safest and most effective way of NT. The current evidence to support the use of NT is limited. However, when used, it should be applied in the 2nd intercostal space at midclavicular line using a catheter length of at least 4.5 cm. Alternative measures should be studied for better prehospital management of tension pneumothorax. PMID:26633663

  4. A novel suture method to place and adjust peripheral nerve catheters

    DEFF Research Database (Denmark)

    Rothe, C.; Steen-Hansen, C.; Madsen, M. H.; Lundstrøm, Lars Hyldborg; Heimburger, R.; Jensen, K. E.; Lange, K. H. W.

    2015-01-01

    We have developed a peripheral nerve catheter, attached to a needle, which works like an adjustable suture. We used in-plane ultrasound guidance to place 45 catheters close to the femoral, saphenous, sciatic and distal tibial nerves in cadaver legs. We displaced catheters after their initial...... placement and then attempted to return them to their original positions. We used ultrasound to evaluate the initial and secondary catheter placements and the spread of injectate around the nerves. In 10 cases, we confirmed catheter position by magnetic resonance imaging. We judged 43/45 initial placements...

  5. New Coaxial Transseptal Needle for Creation of Atrial Septal Defects in Adult Sheep

    International Nuclear Information System (INIS)

    Objectives: To introduce a new transseptal (TS) needle assembled in our laboratory—the coaxial TS (CTS) needle—and describe our experience with it in creating experimental atrial septal defects (ASD) in adult sheep.BackgroundWith commercially available TS needles, we were not able to consistently perform TS puncture at the fossa ovalis in adult sheep.Material and MethodsTen adult sheep with a mean weight of 63.5 kg were used. The CTS needle consists of four components: a 9F Teflon catheter, a 14-gauge blunt curved-tip metal cannula, a 4F tapered catheter, and a 20-gauge open needle. A transjugular 5F pigtail catheter was used to display the septal anatomy by angiocardiography and was left in place to mark the level of the fossa ovalis. The septum was then probed by a transfemoral 5F curved-tip end-hole catheter. The CTS needle was aligned with the tip of the transjugular catheter, and the TS puncture was performed under fluoroscopic guidance. After documenting a left atrial position, a balloon angioplasty catheter was used for creation of the ASD. Results: A small patent foramen ovale was discovered by septal probing in one sheep. All sheep underwent successful TS punctures without complications. The ASD size ranged from 13 to 15 mm. In eight sheep, the ASD was in fossa ovalis. In the first two sheep where the needle was not well aligned with the marking catheter, the ASD was in the septum secundum. No damage to the atrial or other heart structures was found at necropsy. Conclusion: The CTS needle is a suitable needle for TS puncture and ASD creation in adult sheep. Proper alignment of the CTS needle with a catheter marking the fossa ovalis is essential for successful puncture.

  6. Central venous catheters and catheter locks in children with cancer

    DEFF Research Database (Denmark)

    Handrup, Mette Møller; Møller, Jens Kjølseth; Schrøder, Henrik

    2013-01-01

    To determine if the catheter lock taurolidine can reduce the number of catheter-related bloodstream infections (CRBSI) in pediatric cancer patients with tunneled central venous catheters (CVC).......To determine if the catheter lock taurolidine can reduce the number of catheter-related bloodstream infections (CRBSI) in pediatric cancer patients with tunneled central venous catheters (CVC)....

  7. Advanced Imaging Catheter: Final Project Report

    Energy Technology Data Exchange (ETDEWEB)

    Krulevitch, P; Colston, B; DaSilva, L; Hilken, D; Kluiwstra, J U; Lee, A P; London, R; Miles, R; Schumann, D; Seward, K; Wang, A

    2001-07-20

    Minimally invasive surgery (MIS) is an approach whereby procedures conventionally performed with large and potentially traumatic incisions are replaced by several tiny incisions through which specialized instruments are inserted. Early MIS, often called laparoscopic surgery, used video cameras and laparoscopes to visualize and control the medical devices, which were typically cutting or stapling tools. More recently, catheter-based procedures have become a fast growing sector of all surgeries. In these procedures, small incisions are made into one of the main arteries (e.g. femoral artery in the thigh), and a long thin hollow tube is inserted and positioned near the target area. The key advantage of this technique is that recovery time can be reduced from months to a matter of days. In the United States, over 700,000 catheter procedures are performed annually representing a market of over $350 million. Further growth in this area will require significant improvements in the current catheter technology. In order to effectively navigate a catheter through the tortuous vessels of the body, two capabilities must exist: imaging and positioning. In most cases, catheter procedures rely on radiography for visualization and manual manipulation for positioning of the device. Radiography provides two-dimensional, global images of the vasculature and cannot be used continuously due to radiation exposure to both the patient and physician. Intravascular ultrasound devices are available for continuous local imaging at the catheter tip, but these devices cannot be used simultaneously with therapeutic devices. Catheters are highly compliant devices, and manipulating the catheter is similar to pushing on a string. Often, a guide wire is used to help position the catheter, but this procedure has its own set of problems. Three characteristics are used to describe catheter maneuverability: (1) pushability -- the amount of linear displacement of the distal end (inside body) relative to

  8. Needle counter

    International Nuclear Information System (INIS)

    Needle counter had been devised by Geiger about 60 years ago before the present GM counter appeared. It is suitable for the detection of weak radiation because it is limited in effective volume, if the background due to mainly cosmic ray is proportional to the effective volume of the counter. Recently the very low β detector having a needle counter as the main detector has been developed. It showed highly excellent performance in the measurements of small area samples, about ten times sensitive as compared with other detectors. The counter is installed in the very low radiation measuring well at Nokogiriyama, Chiba Prefecture, using a NaI scintillator as its guard counter. D. H. Wilkinson first treated a gas amplification counter theoretically and quantitatively. The authors have obtained good results in the comparison with the experiments of the counter using a generalized form of Wilkinson theory. The findings obtained through this study seem to be applicable to the electrode arrangement which is important for the counter design. It was found that the excellent rise time of induced pulses in a gas amplification counter was achieved in larger amplification factor and smaller convolution effect. In the detection of charged particles with small obstructing capability such as γ ray, faster rise time and higher pulses can be obtained with needle counters than wire counters. (Wakatsuki, Y.)

  9. Suprapubic catheter care

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000145.htm Suprapubic catheter care To use the sharing features on this page, please enable JavaScript. A suprapubic catheter (tube) drains urine from your bladder. It is ...

  10. Central venous catheter - flushing

    Science.gov (United States)

    ... of your catheter and what company made it. Write this information down and keep it handy. To flush your catheter, you will need: Clean paper towels Saline syringes (clear), and maybe heparin syringes ( ...

  11. Guidance of interventions in subintimal recanalization and fenestration of dissection membranes using a novel dual-lumen intravascular ultrasound catheter; Steuerung der Interventionen bei subintimaler Rekanalisation und Fenestration von Dissektionsmembranen durch einen neuartigen zweilumigen intravaskulaeren Ultraschallkatheter

    Energy Technology Data Exchange (ETDEWEB)

    Kickuth, R.; Ludwig, K.C.; Triller, J. [Dept. Radiologie, Neuroradiologie und Nuklearmedizin, Inst. fuer Diagnostische Interventionelle und Paediatrische Radiologie, Inselspital (Switzerland); Do, D.D.; Husmann, M.; Baumgartner, I. [Dept. Herz und Gefaesse DHGE, Klinik und Poliklinik fuer Angiologie (Switzerland)

    2006-09-15

    Purpose: To evaluate the feasibility and effectiveness of IVUS-guided puncture for gaining controlled target lumen reentry in subintimal recanalization of chronic iliac/femoral artery occlusions and in fenestration of aortic dissections. Materials and Methods: Between 5/2004 and 12/2005 12 consecutive patients (7 male, 5 female; mean age 64.6{+-}12.0 years) with chronic critical limb ischemia and ischemic complications of aortic dissection were treated using the Pioneer trademark catheter. This 6.2-F dual-lumen catheter combines a 20-MHz IVUS transducer with a pre-shaped extendable, hollow 24-gauge nitinol needle. This coaxial needle allows real-time IVUS-guided puncture of the target lumen and after successful reentry a 0.014'' guidewire may be advanced through the needle into the target lumen. 7 patients were treated for aortic dissection and 5 patients (with failed previous attempts at subintimal recanalization) for chronic arterial occlusion. Patients with aortic dissection (5 type A dissections, 2 type B dissections) had developed renal ischemia (n=2), renal and mesenteric ischemia (n=2), or low extremity ischemia (n=3). Patients with chronic arterial occlusions (2 common iliac artery occlusions, 3 superficial femoral artery occlusions) experienced ischemic rest pain (n=4), and a non-healing foot ulcer (n=1). Results: The technical success rate using the Pioneer catheter was 100%. The recanalization/fenestration time was 37{+-}12 min. Procedure-related complications did not occur. In 10 cases a significant improvement of clinical symptoms was evident. One patient with aortic dissection and ischemic paraplegia required subsequent surgical intervention. One patient had persistent ischemic rest pain despite successful recanalization of a superficial femoral artery occlusion. (orig.)

  12. Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

    International Nuclear Information System (INIS)

    Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V100Prostate>90%) and organ-at-risk dose sparing (V75Bladder75Rectum125Urethra<<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter patterns may

  13. Needle autopsy

    Directory of Open Access Journals (Sweden)

    Philip Davis Marsden

    1997-04-01

    Full Text Available Often in tropical practice there is not time or conditions to do a proper autopsy on a patient who has died. A needle biopsy technique is described for limited closed autopsy examination to clariffy organ histology. In this way the clinician may resolve puzzling fatal disease.Muitas vezes, em clínicas de países tropicais, não há tempo nem condições para se realizar uma necropsia adequada em um paciente que foi a óbito. Um técnica de biópsia por punção é descrita para fins de exame em necropsia limitadamente fechada, para esclarecimento da histologia do órgão. Dessa maneira, o clínico pode resolver enigmas de doenças fatais.

  14. Subcutaneous infusion: non-metal cannulae vs metal butterfly needles.

    Science.gov (United States)

    Torre, Maria Carrion

    2002-07-01

    This review aimed to evaluate the effectiveness of non-metal cannulae compared to metal butterfly needles in maintaining subcutaneous infusion sites in patients receiving palliative care. The Cochrane Library, Medline, Pre-Medline, Embase, CINAHL, Amed and Cancerlit were searched for relevant studies. Controlled trials comparing non-metal cannulae with metal butterfly needles for giving subcutaneous infusion to palliative care patients were included. The outcome considered was site duration in terms of hours of patency or until change was required. Four trials met the inclusion criteria although overall quality was poor due to low follow-up. Studies examined either Teflon or Vialon-coated catheters. All studies showed non-metal cannulae to be superior to metal. In individual studies estimates in mean increase in duration of the site range from 21 to 159 hours. It seems that non-metal cannulae are more effective in maintaining the duration of subcutaneous infusion sites than butterfly needles. Both types of non-metal catheter showed clear benefits. This review has not examined other outcomes but in general adverse effects lead to the removal of the catheter and so would be reflected in the outcome of considered. Although historically non-metal cannulae have been considerably more expensive there is now little difference between metal and Teflon-coated catheters. This review recommends the use of non-metal cannulae in preference to butterfly needles. PMID:12131852

  15. Implantation of Hickman catheters

    International Nuclear Information System (INIS)

    Hickmann catheters are used mainly in patients with hematologic diseases, especially lymphatic and myelotic leukemias, and malignant lymphomas. They facilitate the administration of chemotherapeutics, hyperosmolar solutions and other substances with local toxicity as well as frequent taking of blood samples. Usually Hickmann catheters are placed by surgical cutdown on a jugular vein. In lieu of this surgical placement, we recommend the implantation of Hickman catheters by means of interventional radiology techniques. In a period of 13 months 78 Hickman catheters were placed in 67 patients. 37 catheters (=47%) stayed more than one month, 8 catheters (=10%) stayed 5 to 8 months in the central venous system. 26, respectively 6, of these catheters are until now in situ. Lethal or life threatening complications did not occur. There were no infections at the introduction site of the catheter. The main complications were: Pneumothorax without drainage: 3.2%, pneumothorax with drainage: 3.2%, slipping back of the tip of the catheter: 4.8%, thrombosis of the subclavian vein: 3.2%, fluid in the pleural cavity: 1.6%. In correspondance to the literature the complications of Hickman catheter placement by means of interventional radiology are less serious than by means of surgical cutdown. Further advantages are: General anesthesia can be avoided (less strain on severely ill patients, no problems to wean from assisted ventilation in patients with respiratory insufficiency), the smooth curve of the implanted catheter avoids sharp kinking and occlusion of the lumen, very small skin incisions are sufficient (lesser risk of hematomas in patients with thrombopenia), time and cost are reduced in comparison to surgical placement. (orig.)

  16. Technical developments: use of targeting guide wire in left subclavian puncture during percutaneous implantation of port-catheter systems using the catheter tip fixation method

    International Nuclear Information System (INIS)

    Our objective was to evaluate the feasibility and safety of a new method in approaching the access route percutaneously for the implantable port-catheter system for repeated hepatic arterial infusion chemotherapy. Fifteen patients underwent port-catheter system placement via the left subclavian artery with the catheter tip fixed within the gastroduodenal artery with embolic materials and a catheter side hole opening to the common hepatic artery. Before port-catheter placement, the right gastric artery was embolized via the femoral catheter access. Then a 0.035-in. guide wire was inserted from the right femoral artery to the left subclavian artery. The guide wire was left in place during puncture by the needle as an access route for catheter placement. At the time of puncture, the tip of the puncture needle was aimed at the guide wire placed in the subclavian artery beforehand. In all 15 patients the procedure was successfully completed in a reasonable time (mean time 95.0 min, range 50-240 min). Complications occurred in two patients: a transient numbness of the arm in 1 patient and a mild hematoma detected in the subcutaneous pocket in another patient. This experience indicates the possibility of using a targeting guide wire in puncture of the subclavian artery as an access route for catheter placement. (orig.)

  17. Preliminary work of a smart needling project

    Science.gov (United States)

    Yan, Kaiguo; Liu, Tien-I.; Ling, Keck Voon; Yu, Yan; O'Dell, Walter; Sing, Ng Wan

    2005-04-01

    Precise needle placement is vital for the success of a wide variety of percutaneous surgical procedures. Insertions into soft tissues can be difficult to learn and to perform, due to tissue deformation, needle deflection and limited visual feedback. Little quantitative information is known about the interaction between needles and soft tissues during puncture. We are carrying out a "smart needling" project in which a fairly long, but slender biopsy needle will be controlled to hit the target that is inside human body, automatically and precisely. This paper reports the preliminary work which is to prove that translational oscillation of the needle can reduce target movement, and at the same time to find the optimal settings of the important factors that will produce the least target movement. The experiment platform comprises of an oscillatory needle restricted to translate horizontally. A position-trackable catheter was embedded in the phantom to act as the target. Two-Level factorial design was adopted and an exploratory data analysis (EDA) approach was used for analysis. The final results showed that oscillation at high frequency band from 2kHz to 20kHz can reduce target movement. Translation speed, oscillation frequency and amplitude are all important factors. But phantoms with different elasticities may have different best settings of these factors. For example, for soft phantoms, lower frequency, higher speed and smaller amplitude are desired for minimal target movement. Optimization searching engine will be designed correspondingly to control the needle in optimal working conditions that can produce minimal target movement.

  18. Self-Assemblies of Acicular Hollow Fe/C Nanostructures.

    Science.gov (United States)

    Li, Wangchang; Qiao, Xiaojing; Li, Mingyu; Zheng, Qiuyu; Ren, Qingguo; Zhu, Y Q; Peng, H X

    2015-08-01

    Self-assemblies of acicular hollow Fe/C structures were synthesized using D-glucose monohydrate and ferric chloride as precursors by a simple hydrothermal process followed by carbonization at 800 °C. The self-assembled structures with an overall diameter of 15~20 µm composed of radially formed hollow needles from a central core with an average diameter of ca. 1 µm and a length up to 10 µm. The end of the needles was revealed to be a awl shape with a hollow structure formed during the self-assembly process and the subsequent heat treatment. The hollow structure was probably caused by the Kirkendall effect at 800 °C. The materials exhibit ferromagnetic characteristic with saturation magnetization (Ms), remanent magnetization (Mr), and coercivity (Hc) of 22.2 emu/g, 3 emu/g, and 151.22 Oe, respectively, with Ms much lower than that of Fe3O4. PMID:26369160

  19. [Suprapubic catheter insertion].

    Science.gov (United States)

    Neumann, Eva; Schwentner, Christian

    2016-01-01

    The suprapubic catheter enables a percutaneous drainage of urine. The insertion is made superior of the pubic bone through the abdominal wall into the bladder. It allows a permanent drainage of urine bypassing the urethra. The insertion of a suprapubic catheter requires knowledge and expertise. This paper summarizes the basic background and allows to follow the practical application step by step. PMID:26800072

  20. Integer Programs for High Dose Rate Brachytherapy Needle and Dose Planning that Directly Optimize Clinical Objectives

    OpenAIRE

    Siauw, Ko-Ay Timmy

    2012-01-01

    High dose rate (HDR) brachytherapy is a radiation therapy for cancer in the prostate, cervix, breast, head, and neck, including other sites. In HDR brachytherapy, hollow needles are inserted or placed near the cancer site. Radiation is delivered to the patient by a radioactive source which is sequentially threaded through the needles. The dose distribution is controlled by altering the dwell times, the time spent at pre-defined positions on the needles.HDR brachytherapy has a 90\\% cancer-free...

  1. Dosimetric equivalence of non-standard high dose rate (HDR) brachytherapy catheter patterns

    CERN Document Server

    Cunha, J Adam M; Pouliot, Jean

    2009-01-01

    Purpose: To determine whether alternative HDR prostate brachytherapy catheter patterns can result in improved dose distributions while providing better access and reducing trauma. Methods: Prostate HDR brachytherapy uses a grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. On CT data from ten previously-treated patients new catheters were digitized following three catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a p...

  2. Auditing urinary catheter care.

    Science.gov (United States)

    Dailly, Sue

    Urinary catheters are the main cause of hospital-acquired urinary tract infections among inpatients. Healthcare staff can reduce the risk of patients developing an infection by ensuring they give evidence-based care and by removing the catheter as soon as it is no longer necessary. An audit conducted in a Hampshire hospital demonstrated there was poor documented evidence that best practice was being carried out. Therefore a urinary catheter assessment and monitoring tool was designed to promote best practice and produce clear evidence that care had been provided. PMID:22375340

  3. Needle Biopsy of the Lung

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Needle Biopsy of the Lung Needle biopsy of the lung ... Needle Biopsy of Lung Nodules? What is Needle Biopsy of the Lung? A lung nodule is relatively ...

  4. Comparison of metal versus Vialon subcutaneous catheters in a palliative care setting.

    Science.gov (United States)

    Currow, D; Cooney, N

    1994-10-01

    In 63 evaluable palliative care patients requiring intermittent bolus subcutaneous administration of medication, who were randomly assigned either a standard metal subcutaneous needle or a PTFE (Vialon) catheter, there was a significantly greater incidence of local reactions at the insertion site with the metal needles (9/30) compared with the PTFE catheters (2/33). Despite this, there was no significant difference between the two in functional survival. Volume of medication injected per day was the best predictor of total time that the subcutaneous lines remained in situ. PMID:7812483

  5. Hollow MEMS

    DEFF Research Database (Denmark)

    Larsen, Peter Emil

    Miniaturization of electro mechanical sensor systems to the micro range and beyond has shown impressive sensitivities measuring sample properties like mass, viscosity, acceleration, pressure and force just to name a few applications. In order to enable these kinds of measurements on liquid samples...... a hollow MEMS sensor has been designed, fabricated and tested. Combined density, viscosity, buoyant mass spectrometry and IR absorption spectroscopy are possible on liquid samples and micron sized suspended particles (e.g. single cells). Measurements are based on changes in the resonant behavior of...... these sensors. Optimization of the microfabrication process has led to a process yield of almost 100% .This is achieved despite the fact, that the process still offers a high degree of flexibility. By simple modifications the Sensor shape can be optimized for different size ranges and sensitivities...

  6. Transbronchial needle aspiration. An underused diagnostic technique.

    Science.gov (United States)

    Dasgupta, A; Mehta, A C

    1999-03-01

    Despite its proven usefulness, TBNA is not widely used. An American College of Chest Physicians (ACCP) survey showed that only 11.8% of pulmonologists use TBNA. Most pulmonologists in the 1980s were not formally trained in TBNA. This lack of training has unfortunately translated to minimal emphasis on TBNA in current training programs in a large number of institutions. Technical problems with the procedure (faulty site selection, incomplete needle penetration, catheter kinking that prevents adequate suction, etc.), the confusing array of needles, low diagnostic yields, unproven concerns regarding the safety of the procedure, inadequate cytopathology support, and bronchoscopic damage have all perpetuated the image of limited usefulness for this procedure. Limitations to the practice of TBNA are: Lack of training during fellowship Technical inadequacies Lack of cytopathologists trained in TBNA interpretation Fear of bronchoscope damage Safety issues Failure to reproduce published successes Reservations regarding usefulness of TBNA results Hands-on experience with TBNA, developing familiarity and expertise with only a few needles, and paying careful attention to anatomy, procedure techniques, and specimen acquisition may all help to increase yield. The following lists how better results can be obtained with TBNA: Preprocedure Review TBNA instruction tapes Attend hands-on courses Practice with lung models Review patient's CAT scans Familiarize with one-two cytology and histology needle Obtain a trained assistant Procedural Identify target site Needle to airway angle at least greater than 45 degrees Insert entire length of the needle Use scope channel to support the catheter Release suction before withdrawing needle (for staging) Specimen acquisition Avoid delay in preparing slides Adequate sampling (at least two) Use smear method for cytology specimen Analyze all samples flush solutions cell block Postprocedure Find an experienced cytopathologist Review your procedure

  7. Effects of insertion speed and trocar stiffness on the accuracy of needle position for brachytherapy

    International Nuclear Information System (INIS)

    Purpose: In prostate brachytherapy, accurate positioning of the needle tip to place radioactive seeds at its target site is critical for successful radiation treatment. During the procedure, needle deflection leads to seed misplacement and suboptimal radiation dose to cancerous cells. In practice, radiation oncologists commonly use high-speed hand needle insertion to minimize displacement of the prostate as well as the needle deflection. Effects of speed during needle insertion and stiffness of trocar (a solid rod inside the hollow cannula) on needle deflection are studied. Methods: Needle insertion experiments into phantom were performed using a 22 factorial design (2 parameters at 2 levels), with each condition having replicates. Analysis of the deflection data included calculating the average, standard deviation, and analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: The stiffer tungsten carbide trocar is effective in reducing the average and standard deviation of needle deflection. The fast insertion speed together with the stiffer trocar generated the smallest average and standard deviation for needle deflection for almost all cases. Conclusions: The combination of stiff tungsten carbide trocar and fast needle insertion speed are important to decreasing needle deflection. The knowledge gained from this study can be used to improve the accuracy of needle insertion during brachytherapy procedures.

  8. Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, J. A. M.; Hsu, I-C.; Pouliot, J. [University of California, San Francisco, California 94115 (United States)

    2009-01-15

    Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V{sub 100}{sup Prostate}>90%) and organ-at-risk dose sparing (V{sub 75}{sup Bladder}<1 cc, V{sub 75}{sup Rectum}<1 cc, V{sub 125}{sup Urethra}<<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of

  9. NURSING CARE IN PATIENTS NEONATES WITH PERIPHERALLY INSERTED CENTRAL CATHETER

    Directory of Open Access Journals (Sweden)

    Anacilda Oliveira Vieira

    2013-12-01

    Full Text Available Introduction: The PICC (peripherally inserted central catheter is a long flexible catheter which is inserted through a peripheral vein, progresses through a needle introducer until the final portion of the vena cava, acquiring characteristics of a central catheter. Objective: To point out the main theoretical and scientific ideas that demonstrate the reliability, competence and ability of nurses to perform the PICC. Methodology: Systematic review of articles, which were found by searching the database scientific journals and bibliographies area. Results: The success of integration depends on the patient assessment and choice of venous access where the catheter will be positioned, and its tip should be in the middle third of the superior vena cava, or the middle third of the inferior vena cava. In neonates, which are used more frequently, proper positioning of the catheter is through nursing care in making the dressing, and the first 24 hours it should be compressive. Ideally, the PICC remains in the vein for periods longer than seven days or until the end of treatment, thus decreasing invasive procedures. Conclusion: According to the Federal Board of Nursing (COFEN, it is lawful for the insertion of PICC nurses, provided it has undergone professional training.

  10. Central venous catheter insertion problem solving using intravenous catheter: technical communication

    Directory of Open Access Journals (Sweden)

    Alemohammad M

    2013-02-01

    Full Text Available Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will not pass freely.During central venous insertion in internal jugular vein using modified seldinger technique, when after venous insertion, the passage of the guide wire shows difficulties and don’t pass freely, insertion of an intravenous cannula over the wire and re-insertion of the wire can help to prevent malposition of the wire and the catheter. Use of an intravenous cannula over the guide, in situations that the guide wire cannot pass freely among the needle inserted in internal jugular vein, and re-insertion of the guide can probably prevent or reduce the tissue or vascular trauma and the associated complica-tions. This simple maneuver can be helpful in difficult cases especially in cardiac surgery patients who receive high dose heparin and it is necessary to avoid traumatize-tion of carotid artery.

  11. Catheter-related bloodstream infection.

    Science.gov (United States)

    Goede, Matthew R; Coopersmith, Craig M

    2009-04-01

    Catheter-related bloodstream infections (CR-BSIs) are a common, frequently preventable complication of central venous catheterization. CR-BSIs can be prevented by strict attention to insertion and maintenance of central venous catheters and removing unneeded catheters as soon as possible. Antiseptic- or antibiotic-impregnated catheters are also an effective tool to prevent infections. The diagnosis of CR-BSI is made largely based on culture results. CR-BSIs should always be treated with antibiotics, and except in rare circumstances the infected catheter needs to be removed. PMID:19281894

  12. Precessing Ferromagnetic Needle Magnetometer

    Science.gov (United States)

    Jackson Kimball, Derek F.; Sushkov, Alexander O.; Budker, Dmitry

    2016-05-01

    A ferromagnetic needle is predicted to precess about the magnetic field axis at a Larmor frequency Ω under conditions where its intrinsic spin dominates over its rotational angular momentum, N ℏ≫I Ω (I is the moment of inertia of the needle about the precession axis and N is the number of polarized spins in the needle). In this regime the needle behaves as a gyroscope with spin N ℏ maintained along the easy axis of the needle by the crystalline and shape anisotropy. A precessing ferromagnetic needle is a correlated system of N spins which can be used to measure magnetic fields for long times. In principle, by taking advantage of rapid averaging of quantum uncertainty, the sensitivity of a precessing needle magnetometer can far surpass that of magnetometers based on spin precession of atoms in the gas phase. Under conditions where noise from coupling to the environment is subdominant, the scaling with measurement time t of the quantum- and detection-limited magnetometric sensitivity is t-3 /2. The phenomenon of ferromagnetic needle precession may be of particular interest for precision measurements testing fundamental physics.

  13. Use of ultrasound to facilitate femoral nerve block with stimulating catheter

    Institute of Scientific and Technical Information of China (English)

    LI Min; XU Ting; HAN Wen-yong; WANG Xue-dong; JIA Dong-lin; GUO Xiang-yang

    2011-01-01

    Background The adjunction of ultrasound to nerve stimulation has been proven to improve single-injection peripheral nerve block quality. However, few reports have been published determining whether ultrasound can facilitate continuous nerve blocks. In this study, we tested the hypothesis that the addition of ultrasound to nerve stimulation facilitates femoral nerve blocks with a stimulating catheter.Methods In this prospective randomized study, patients receiving continuous femoral nerve blocks for total knee replacement were randomly assigned to either the ultrasound guidance combined with stimulating catheter group (USNS group; n=60) or the stimulating catheter alone group (NS group; n=60). The primary end point was the procedure time (defined as the time from first needle contact with the skin until correct catheter placement). The numbers of needle passes and catheter insertions, onset and quality of femoral nerve blocks, postoperative pain score, and early knee function were also recorded.Results The procedure time was significantly less in the USNS group than in the NS group (9.0 (6.0-22.8) minutes vs.13.5 (6.0-35.9) minutes, P=0.024). The numbers of needle passes and catheter insertions were also significantly less in the USNS group. A greater complete block rate was achieved at 30 minutes in the USNS group (63.3% vs. 38.3%;P=0.010). The postoperative pain score, the number of patients who required bolus local anesthetic and intravenous patient-controlled analgesia, and knee flexion on the second postoperative day were not significantly different between the two groups of patients.Conclusions Ultrasound-assisted placement of a stimulating catheter for femoral nerve blocks decreases the time necessary to perform the block compared with just the nerve-stimulating technique. In addition, a more complete blockade is achieved using the ultrasound-assisted technique.

  14. Hollow dimension of modules

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    In this paper, we are interested in the following general question: Given a module Mwhich has finite hollow dimension and which has a finite collection of submodules Ki (1≤i≤n) such that M=K1+... +Kn, can we find an expression for the hollow dimension of Min terms of hollow dimensions of modules built up in some way from K1 Kn? We prove the following theorem:Let Mbe an amply supplemented module having finite hollow dimension and let Ki (1≤i≤n) be a finite collection of submodules of Msuch that M=K1+...+Kn. Then the hollow dimension h(M) of Mis the sum of the hollow dimensions of Ki (1≤i≤n) ifand only if Ki is a supplement of K1+...+Ki-1+Ki+1+...+Kn in Mfor each 1≤i≤n.

  15. Radiologic placement of Hickman catheters

    International Nuclear Information System (INIS)

    Hickman catheter inserter has previously been predominantly accomplished surgically by means of venous cutdown or percutaneous placement in the operating room. The authors describe their method and results for 55 consecutive percutaneous placements of Hickman catheters in the interventional radiology suite. Complication rates were comparable to those for surgical techniques. Radiologic placement resulted in increased convenience, decreased time and cost of insertion, and super fluoroscopic control of catheter placement and any special manipulations. Modern angiographic materials provide safer access to the subclavian vein than traditional methods. The authors conclude that radiologic placement of Hickman catheters offers significant advantages over traditional surgical placement

  16. Pleural needle biopsy

    Science.gov (United States)

    ... et al, eds. Murray and Nadel's Textbook of Respiratory Medicine . 6th ed. Philadelphia, PA: Elsevier Saunders; 2016:chap 19. Ly A. Fine-needle aspiration biopsy technique and specimen ... Respiratory system. In: Watson N. Chapman and Nakielny's Guide ...

  17. Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Im [Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Kyung Hee University Hospital at Gangdong, Kyung Hee University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Park, Chang Min; Goo, Jin Mo [Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of); Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of); Lee, Sang Min [Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of)

    2015-07-15

    To investigate the effect of rapid needle-out patient-rollover approach on the incidence of pneumothorax and drainage catheter placement due to pneumothorax in C-arm Cone-beam CT (CBCT)-guided percutaneous transthoracic needle biopsy (PTNB) of lung lesions. From May 2011 to December 2012, 1227 PTNBs were performed in 1191 patients with a 17-gauge coaxial needle. 617 biopsies were performed without (conventional-group) and 610 with rapid-rollover approach (rapid-rollover-group). Overall pneumothorax rates and incidences of pneumothorax requiring drainage catheter placement were compared between two groups. There were no significant differences in overall pneumothorax rates between conventional and rapid-rollover groups (19.8 % vs. 23.1 %, p = 0.164). However, pneumothorax rate requiring drainage catheter placement was significantly lower in rapid-rollover-group (1.6 %) than conventional-group (4.2 %) (p = 0.010). Multivariate analysis revealed male, age > 60, bulla crossed, fissure crossed, pleura to target distance > 1.3 cm, emphysema along needle tract, and pleural punctures ≥ 2 were significant risk factors of pneumothorax (p < 0.05). Regarding pneumothorax requiring drainage catheter placement, fissure crossed, bulla crossed, and emphysema along needle tract were significant risk factors (p < 0.05), whereas rapid-rollover approach was an independent protective factor (p = 0.002). The rapid needle-out patient-rollover approach significantly reduced the rate of pneumothorax requiring drainage catheter placement after CBCT-guided PTNB. (orig.)

  18. Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients

    International Nuclear Information System (INIS)

    To investigate the effect of rapid needle-out patient-rollover approach on the incidence of pneumothorax and drainage catheter placement due to pneumothorax in C-arm Cone-beam CT (CBCT)-guided percutaneous transthoracic needle biopsy (PTNB) of lung lesions. From May 2011 to December 2012, 1227 PTNBs were performed in 1191 patients with a 17-gauge coaxial needle. 617 biopsies were performed without (conventional-group) and 610 with rapid-rollover approach (rapid-rollover-group). Overall pneumothorax rates and incidences of pneumothorax requiring drainage catheter placement were compared between two groups. There were no significant differences in overall pneumothorax rates between conventional and rapid-rollover groups (19.8 % vs. 23.1 %, p = 0.164). However, pneumothorax rate requiring drainage catheter placement was significantly lower in rapid-rollover-group (1.6 %) than conventional-group (4.2 %) (p = 0.010). Multivariate analysis revealed male, age > 60, bulla crossed, fissure crossed, pleura to target distance > 1.3 cm, emphysema along needle tract, and pleural punctures ≥ 2 were significant risk factors of pneumothorax (p < 0.05). Regarding pneumothorax requiring drainage catheter placement, fissure crossed, bulla crossed, and emphysema along needle tract were significant risk factors (p < 0.05), whereas rapid-rollover approach was an independent protective factor (p = 0.002). The rapid needle-out patient-rollover approach significantly reduced the rate of pneumothorax requiring drainage catheter placement after CBCT-guided PTNB. (orig.)

  19. Intracerebral sewing needle.

    Science.gov (United States)

    Yolas, C; Aydin, M D; Ozdikici, M; Aydin, N; Onder, A

    2007-01-01

    A 9-year-old male patient complaining of seizure attack was admitted to the neurosurgery department. Radiologic investigations revealed a 5-cm-long metallic sewing needle extending from the right frontal cortex to the right lateral ventricle. Burr hole surgery was performed and the needle was grasped with biopsy forceps and removed with endoscopic guidance. The patient recovered without any complications. PMID:17786012

  20. Hollow spherical supramolecular dendrimers.

    Science.gov (United States)

    Percec, Virgil; Peterca, Mihai; Dulcey, Andrés E; Imam, Mohammad R; Hudson, Steven D; Nummelin, Sami; Adelman, Peter; Heiney, Paul A

    2008-10-01

    The synthesis of a library containing 12 conical dendrons that self-assemble into hollow spherical supramolecular dendrimers is reported. The design principles for this library were accessed by development of a method that allows the identification of hollow spheres, followed by structural and retrostructural analysis of their Pm3n cubic lattice. The first hollow spherical supramolecular dendrimer was made by replacing the tapered dendron, from the previously reported tapered dendritic dipeptide that self-assembled into helical pores, with its constitutional isomeric conical dendron. This strategy generated a conical dendritic dipeptide that self-assembled into a hollow spherical supramolecular dendrimer that self-organizes in a Pm3n cubic lattice. Other examples of hollow spheres were assembled from conical dendrons without a dipeptide at their apex. These are conical dendrons originated from tapered dendrons containing additional benzyl ether groups at their apex. The inner part of the hollow sphere assembled from the dipeptide resembles the path of a spherical helix or loxodrome and, therefore, is chiral. The spheres assembled from other conical dendrons are nonhelical, even when they contain stereocenters on the alkyl groups from their periphery. Functionalization of the apex of the conical dendrons with diethylene glycol allowed the encapsulation of LiOTf and RbOTf in the center of the hollow sphere. These experiments showed that hollow spheres function as supramolecular dendritic capsules and therefore are expected to display functions complementary to those of other related molecular and supramolecular structures. PMID:18771261

  1. Balloon catheter coronary angioplasty

    International Nuclear Information System (INIS)

    The author has produced a reference and teaching book on balloon angioplasty. Because it borders in surgery and is performed on an awake patient without circulatory assistance, it is a complex and demanding procedure that requires thorough knowledge before it is attempted. The text is divided into seven sections. The first section describes coronary anatomy and pathophysiology, defines the objectives and mechanisms of the procedure and lists four possible physiologic results. The next section describes equipment in the catheterization laboratory, catheters, guidewires and required personnel. The following section is on the procedure itself and includes a discussion of examination, testing, technique and follow-up. The fourth section details possible complications that can occur during the procedure, such as coronary spasms, occlusion, thrombosis, perforations and ruptures, and also discusses cardiac surgery after failed angioplasty. The fifth section details complex or unusual cases that can occur. The sixth and seventh sections discuss radiation, alternative procedures and the future of angioplasty

  2. Fine needle aspiration of the thyroid

    Science.gov (United States)

    Thyroid nodule fine needle aspirate biopsy; Biopsy - thyroid - skinny-needle; Skinny-needle thyroid biopsy ... cleaned. A thin needle is inserted into the thyroid, and a sample of thyroid cells and fluid ...

  3. Mechanics of needle-tissue interaction

    NARCIS (Netherlands)

    Roesthuis, Roy J.; Veen, van Youri R.J.; Jahya, Alex; Misra, Sarthak

    2011-01-01

    When a needle is inserted into soft tissue, interac- tion forces are developed at the needle tip and along the needle shaft. The needle tip force is due to cutting of the tissue, and the force along the needle shaft is due to friction between needle and tissue. In this study, the friction force is d

  4. Delayed bowel perforation following suprapubic catheter insertion

    OpenAIRE

    Mehta Ajay; Ahmed Shwan J; Rimington Peter

    2004-01-01

    Abstract Background Complications of suprapubic catheter insertion are rare but can be significant. We describe an unusual complication of a delayed bowel perforation following suprapubic catheter insertion. Case presentation A gentleman presented with features of peritonitis and feculent discharge along a suprapubic catheter two months after insertion of the catheter. Conclusion Bowel perforation is the most feared complication of suprapubic catheter insertion especially in patients with low...

  5. Fricke gel dosimetric catheters in high dose rate brachytherapy. In phantom dose distribution measurements of a 5 catheter implant

    International Nuclear Information System (INIS)

    Due to the complexity and the many steps involved in a high dose rate brachytherapy process, radiation dose delivered to the patient during the treatment is susceptible to many inaccuracies and may not accurately match the planned dose. In vivo dosimetry is a reliable solution to compare planned and delivered dose distributions, representing therefore a valid tool to systematically perform a quality control of the radiotherapic process and eventually increment treatment accuracy. In this study, Fricke gel dosimetric catheters (FGDC) were investigated to perform dose distribution measurements of a brachytherapy implant. The brachytherapy implant was established in a water phantom with five flexible plastic needles and irradiation was performed with a high dose rate remote afterloading device provided with an Ir-192 radioactive source. Comparison between dose distributions measured with ten FGDC located in the proximity of the implant needles and calculated by the treatment planning system shows very good agreement for seven out of ten dosimeters, whereas the remaining three show a local underestimation of the dose. In phantom results indicate that Fricke gel dosimetric catheters might be valid candidates for performing in vivo dosimetry in high dose rate brachytherapy. However, further measurements are still required to validate this dosimetric method.

  6. Hollow nuclear matter

    OpenAIRE

    Yong, Gao-Chan

    2015-01-01

    It is generally considered that an atomic nucleus is always compact. Based on the isospin-dependent Boltzmann nuclear transport model, here I show that large block nuclear matter or excited nuclear matter may both be hollow. And the size of inner bubble in these matter is affected by the charge number of nuclear matter. Existence of hollow nuclear matter may have many implications in nuclear or atomic physics or astrophysics as well as some practical applications.

  7. Hollow nuclear matter

    CERN Document Server

    Yong, Gao-Chan

    2016-01-01

    It is generally considered that an atomic nucleus is always compact. Based on the isospin-dependent Boltzmann nuclear transport model, here I show that large block nuclear matter or excited nuclear matter may both be hollow. And the size of inner bubble in these matter is affected by the charge number of nuclear matter. Existence of hollow nuclear matter may have many implications in nuclear or atomic physics or astrophysics as well as some practical applications.

  8. Hydrodynamics of catheter biofilm formation

    CERN Document Server

    Sotolongo-Costa, Oscar; Rodriguez-Perez, Daniel; Martinez-Escobar, Sergio; Fernandez-Barbero, Antonio

    2009-01-01

    A hydrodynamic model is proposed to describe one of the most critical problems in intensive medical care units: the formation of biofilms inside central venous catheters. The incorporation of approximate solutions for the flow-limited diffusion equation leads to the conclusion that biofilms grow on the internal catheter wall due to the counter-stream diffusion of blood through a very thin layer close to the wall. This biological deposition is the first necessary step for the subsequent bacteria colonization.

  9. New ferromagnetic catheters for MR imaging

    International Nuclear Information System (INIS)

    Newly developed ferromagnetic catheters are more conspicuous than conventional radiographic catheters on MR images because they produce characteristic ferromagnetic signal patterns (FSPs). The authors systematically imaged ferromagnetic catheters (ferromagnetic concentration, 0.1--1.0 weight/weight%) in phantoms at 0.38 T and 1.5 T and compared their appearance with that of three radiographic catheters. The radiographic catheters always produced a signal void. The ferromagnetic catheters produced FSPs when perpendicular to the magnetic field, and the FSPs depended on the ferromagnetic concentration, strength of the main magnetic field, and the direction and strength of the frequency-encoding gradient. The ferromagnetic catheters produced no FSP when parallel to the magnetic field. Ferromagnetic catheters produce conspicuous FSPs on MR images, which depend on catheter position and the MR imaging parameters selected

  10. Intracorporeal knotting of a femoral nerve catheter

    Directory of Open Access Journals (Sweden)

    Ghanem, Mohamed

    2015-01-01

    Full Text Available Peripheral nerve catheters are effective and well-established tools to provide postoperative analgesia to patients undergoing orthopedic surgery. The performance of these techniques is usually considered safe. However, placement of nerve catheters may be associated with a considerable number of side effects and major complications have repeatedly been published. In this work, we report on a patient who underwent total knee replacement with spinal anesthesia and preoperative insertion of femoral and sciatic nerve catheters for postoperative analgesia. During insertion of the femoral catheter, significant resistance was encountered upon retracting the catheter. This occurred due to knotting of the catheter. The catheter had to be removed by operative intervention which has to be considered a major complication. The postoperative course was uneventful. The principles for removal of entrapped peripheral catheters are not well established, may differ from those for neuroaxial catheters, and range from cautious manipulation up to surgical intervention.

  11. Treatment feasibility study of osteoporosis using minimal invasive laser needle system

    Science.gov (United States)

    Kang, Dongyeon; Ko, Chang-Yong; Ryu, Yeon-Hang; Park, Sunwook; Kim, Han-Sung; Jung, Byungjo

    2010-02-01

    Although the mechanism of laser stimulation effect in bone has not completely understood, laser stimulation is recommended in the treatment of osteoporosis due to positive treatment efficacy. In this study, a minimal invasive laser needle system (MILNS) was developed using a fine hollow needle in order to stimulate directly bone site by guiding an optical fiber. In order to evaluate the MILNS as a treatment method, in-vivo animal experiment study was performed using osteopenic mice. Twelve virginal ICR mice were employed and divided two groups: SHAM-group and LASERgroup. SHARM-group was stimulated by only fine hollow needle and LASER-group by fine hollow needle combined with laser stimulation. All mice were served in-vivo micro-CT images before and after treatment. Three dimensional (3D) structural parameters and vBMD (volume bone mineral density, g/cm3) in the trabecular bone were measured. After 2 weeks of stimulation, the vBMD, BV/TV, Tb.Th and Tb.N in LASER-group were significantly higher than those in SHAM-group (p<0.05). Potentially, this study suggested that the MILNS might prevent the bone loss and maintains the bone mineral density of osteopenic mice.

  12. Implantation of peritoneal catheters by laparotomy: nephrologists obtained similar results to general surgeons

    Directory of Open Access Journals (Sweden)

    Restrepo CA

    2014-10-01

    Full Text Available Cesar A Restrepo, Carlos Alberto Buitrago, Cielo Holguin Division of Nephrology, Department of Health Sciences, Caldas University, Caldas, ColombiaPurpose: To analyze the complications and costs of minilaparotomies performed by a nephrologist (group A compared with conventional laparotomies performed by a surgeon (group B for peritoneal catheter implantation.Setting: Two university hospitals (Santa Sofia and Caldas in Manizales, Caldas, Colombia.Methods: The study included stage 5 chronic kidney disease patients, with indication of renal replacement therapy, who were candidates for peritoneal dialysis and gave informed consent for a peritoneal catheter implant. Minilaparotomies were performed by a nephrologist in a minor surgery room under local anesthesia. Conventional laparotomies were performed by a surgeon in an operating room under general anesthesia.Results: Two nephrologists inserted 157 peritoneal catheters, and seven general surgeons inserted 185 peritoneal catheters. The groups had similar characteristics: the mean age was 55 years, 49.5% were men, and the primary diagnoses were diabetic nephropathy, hypertensive nephropathy, and unknown etiology. The implant was successful for 98.09% of group A and 99.46% of group B. There was no procedure-related mortality. The most frequent complications in the first 30 days postsurgery in group A versus group B, respectively, were: peritonitis (6.37% versus 3.78%, exit-site infection (3.82% versus 2.16%, tunnel infection (0% versus 0.54%, catheter entrapment by omentum (1.27% versus 3.24%, peritoneal effluent spillover (1.91% versus 2.16%, draining failure (4.46% versus 6.49%, hematoma (0% versus 1.08%, catheter migration with kinking (3.18% versus 2.70%, hemoperitoneum (1.27% versus 0%, and hollow viscera accidental puncture (1.91% versus 0.54%. There were no statistically significant differences in the number of complications between groups. In 2013, the cost of a surgeon-implanted peritoneal

  13. Evidence of hollow golden cages

    OpenAIRE

    Bulusu, Satya; Li, Xi; Wang, Lai-Sheng; Zeng, Xiao Cheng

    2006-01-01

    The fullerenes are the first “free-standing” elemental hollow cages identified by spectroscopy experiments and synthesized in the bulk. Here, we report experimental and theoretical evidence of hollow cages consisting of pure metal atoms, Aun− (n = 16–18); to our knowledge, free-standing metal hollow cages have not been previously detected in the laboratory. These hollow golden cages (“bucky gold”) have an average diameter >5.5 Å, which can easily accommodate one guest atom inside.

  14. Spinal canal extension of hyperalimentation catheter without neurologic sequela

    International Nuclear Information System (INIS)

    An attempt at placement of a left femoral vein hyperalimentation catheter resulted in entrance of the catheter into the spinal canal. Catheter location was documented by injections of nonionic contrast material into the catheter without neurologic sequellae. (orig.)

  15. Review of catheter thrombectomy devices.

    Science.gov (United States)

    Suarez, Jose A; Meyerrose, Gary E; Phisitkul, Sorot; Kennedy, Shalyn; Roongsritong, Chanwit; Tsikouris, James; Huang, Shoei K Stephen

    2004-01-01

    Acute massive pulmonary embolism (PE) is a frequently fatal event that causes significant compromise of hemodynamic stability. Unfortunately, mortality rates for PE have remained relatively constant despite advances in prophylactic and treatment measures. In addition to embolus size, symptom recognition for diagnosis and emergent treatment are two distinct factors that dictate survival. Treatment generally includes thrombolytic agents; however, not all patients are candidates for aggressive thrombolytic management. Development of catheter thrombectomy devices provides an alternative treatment modality for severe cases when thrombolytics are contraindicated. Catheter thrombectomy devices have undergone major advances over the last decade, but literature support of their success is limited. PMID:14988612

  16. FAQs about Catheter-Associated Bloodstream Infections

    Science.gov (United States)

    ... or groin. The catheter is often used to draw blood, or give fluids or medications. It may ... an antiseptic solution before using the catheter to draw blood or give medications. Healthcare providers also clean ...

  17. A new puncture needle (Seldinger technique) for easy antegrade catheterization of the superficial femoral artery

    International Nuclear Information System (INIS)

    Mainly for anatomical reasons a guide-wire or a catheter has a tendency to turn into the deep femoral artery during antegrade catheterization of the lower limb. To overcome this problem a curved puncture needle has been designed which allows positioning of the guide-wire in an anterior direction. Antegrade catheterization of the superficial femoral artery was achieved in 25 patients without lengthy manipulations or complications. With this technique the rate of complications at antegrade catheterization will probably be reduced. (orig.)

  18. 21 CFR 876.5090 - Suprapubic urological catheter and accessories.

    Science.gov (United States)

    2010-04-01

    .... This generic type of device includes the suprapubic catheter and tube, Malecot catheter, catheter punch... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Suprapubic urological catheter and accessories... Suprapubic urological catheter and accessories. (a) Identification. A suprapubic urological catheter...

  19. Development and application of a microfabricated multimodal neural catheter for neuroscience.

    Science.gov (United States)

    Li, Chunyan; Wu, Zhizhen; Limnuson, Kanokwan; Cheyuo, Cletus; Wang, Ping; Ahn, Chong H; Narayan, Raj K; Hartings, Jed A

    2016-02-01

    We present a microfabricated neural catheter for real-time continuous monitoring of multiple physiological, biochemical and electrophysiological variables that are critical to the diagnosis and treatment of evolving brain injury. The first generation neural catheter was realized by polyimide-based micromachining and a spiral rolling packaging method. The mechanical design and electrical operation of the microsensors were optimized and tailored for multimodal monitoring in rat brain such that the potential thermal, chemical and electrical crosstalk among the microsensors as well as errors from micro-environmental fluctuations are minimized. In vitro cytotoxicity analyses suggest that the developed neural catheters are minimally toxic to rat cortical neuronal cultures. In addition, in vivo histopathology results showed neither acute nor chronic inflammation for 7 days post implantation. The performance of the neural catheter was assessed in an in vivo needle prick model as a translational replica of a "mini" traumatic brain injury. It successfully monitored the expected transient brain oxygen, temperature, regional cerebral blood flow, and DC potential changes during the passage of spreading depolarization waves. We envisage that the developed multimodal neural catheter can be used to decipher the causes and consequences of secondary brain injury processes with high spatial and temporal resolution while reducing the potential for iatrogenic injury inherent to current use of multiple invasive probes. PMID:26780443

  20. Transhepatic venous catheters for hemodialysis

    Directory of Open Access Journals (Sweden)

    Mohamed El Gharib

    2014-06-01

    Conclusion: Based on our findings, transhepatic hemodialysis catheters have proven to achieve good long-term functionality. A high level of maintenance is required to preserve patency, although this approach provides remarkably durable access for patients who have otherwise exhausted access options.

  1. Smart needles for percutaneous interventions

    NARCIS (Netherlands)

    Henken, K.R.

    2014-01-01

    The development of advanced needles for diagnostic and therapeutic purposes such as ablation and brachytherapy in the liver has offered minimally invasive therapies to patients that were previously untreatable. This thesis focuses on accurate placement of such needles guided by magnetic resonance im

  2. Button self-retaining drainage catheter

    International Nuclear Information System (INIS)

    To help improve patient acceptance of long-term internal/external catheter access to the biliary tract in those with benign biliary obstruction, a simple design allows the catheter end to remain flush with the skin. It consists of a clothes button affixed to the drainage catheter with a wood screw after the catheter has been cut off at the skin exit. This button/screw device has been used successfully in 22 patients over the last 10 years; catheter exchanges were easily accomplished

  3. Delayed bowel perforation following suprapubic catheter insertion

    Directory of Open Access Journals (Sweden)

    Mehta Ajay

    2004-12-01

    Full Text Available Abstract Background Complications of suprapubic catheter insertion are rare but can be significant. We describe an unusual complication of a delayed bowel perforation following suprapubic catheter insertion. Case presentation A gentleman presented with features of peritonitis and feculent discharge along a suprapubic catheter two months after insertion of the catheter. Conclusion Bowel perforation is the most feared complication of suprapubic catheter insertion especially in patients with lower abdominal scar. The risk may be reduced with the use of ultrasound scan guidance.

  4. EM-navigated catheter placement for gynecologic brachytherapy: an accuracy study

    Science.gov (United States)

    Mehrtash, Alireza; Damato, Antonio; Pernelle, Guillaume; Barber, Lauren; Farhat, Nabgha; Viswanathan, Akila; Cormack, Robert; Kapur, Tina

    2014-03-01

    Gynecologic malignancies, including cervical, endometrial, ovarian, vaginal and vulvar cancers, cause significant mortality in women worldwide. The standard care for many primary and recurrent gynecologic cancers consists of chemoradiation followed by brachytherapy. In high dose rate (HDR) brachytherapy, intracavitary applicators and /or interstitial needles are placed directly inside the cancerous tissue so as to provide catheters to deliver high doses of radiation. Although technology for the navigation of catheters and needles is well developed for procedures such as prostate biopsy, brain biopsy, and cardiac ablation, it is notably lacking for gynecologic HDR brachytherapy. Using a benchtop study that closely mimics the clinical interstitial gynecologic brachytherapy procedure, we developed a method for evaluating the accuracy of image-guided catheter placement. Future bedside translation of this technology offers the potential benefit of maximizing tumor coverage during catheter placement while avoiding damage to the adjacent organs, for example bladder, rectum and bowel. In the study, two independent experiments were performed on a phantom model to evaluate the targeting accuracy of an electromagnetic (EM) tracking system. The procedure was carried out using a laptop computer (2.1GHz Intel Core i7 computer, 8GB RAM, Windows 7 64-bit), an EM Aurora tracking system with a 1.3mm diameter 6 DOF sensor, and 6F (2 mm) brachytherapy catheters inserted through a Syed-Neblett applicator. The 3D Slicer and PLUS open source software were used to develop the system. The mean of the targeting error was less than 2.9mm, which is comparable to the targeting errors in commercial clinical navigation systems.

  5. Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system

    Energy Technology Data Exchange (ETDEWEB)

    Poulin, Eric; Racine, Emmanuel; Beaulieu, Luc, E-mail: Luc.Beaulieu@phy.ulaval.ca [Département de physique, de génie physique et d’optique et Centre de recherche sur le cancer de l’Université Laval, Université Laval, Québec, Québec G1V 0A6, Canada and Département de radio-oncologie et Axe Oncologie du Centre de recherche du CHU de Québec, CHU de Québec, 11 Côte du Palais, Québec, Québec G1R 2J6 (Canada); Binnekamp, Dirk [Integrated Clinical Solutions and Marketing, Philips Healthcare, Veenpluis 4-6, Best 5680 DA (Netherlands)

    2015-03-15

    Purpose: In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. Methods: For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora{sup ®} Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position and orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. Conclusions: The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators.

  6. Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system

    International Nuclear Information System (INIS)

    Purpose: In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. Methods: For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora® Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position and orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. Conclusions: The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators

  7. Fine needle puncture followed by large tube catheterizing in percutaneous transhepatic cholangic drainage

    International Nuclear Information System (INIS)

    Objective: It's evaluation of fine needle puncture small guild wire insertion, followed by single step large tube catheterization in percutaneous transhepatic cholangic drainage. Methods: In total 37 cases of biliary tract obstruction were investigated, including 31 malignant and 6 benign. After PTC, a.018 guide wire was inserted to bile duct through the 22G chiba needle. The needle tract was dilated to exchange in a.035 guide wire which was then traced through the obstruction to duodenum. The needle tract was dilated and the obstruction was recanalized by a 8 mm balloon catheter. A 12F side holed drainage tube was then placed through the obstruction. Results: Technic success was obtained in 34 procedures, resulting in 28 inner and 6 extra drainage, in which 2 tubes were placed in 3 patients. Serious biliary hemorrhage occurred in 2 cases but was well control. A replacement was commended in 5 cases because of the migration or dislodgement of the drainage tubes. Conclusions: Fine needle puncture an small guild wire insertion avoid another liver puncture by cored needle, leading to a less invasive PTCD. Balloon dilation helps a fluent insertion of large drainage tube

  8. Transthoracic fine needle aspiration biopsy: diagnostic rate and complications in 1000 cases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Mi; Jeon, Seok Chol; Bae, Oh Keun; Choi, Yo Won; Hahm, Chang Kok [School of Medicine, Hanyang University Hospital, Seoul (Korea, Republic of); Kim, Chang Ho [InJe University, Pusan (Korea, Republic of); You, Won Don [Armed Forces General Hospital, Seoul (Korea, Republic of)

    1994-11-15

    Transthoracic fine needle aspiration biopsy is a widely practiced technique in the investigation of the lung and mediastinal masses because of its safety, reliability and accuracy. We report the diagnostic accuracy of the transthoracic fine needle aspiration biopsy and the frequency of its complications which required treatment. We analyzed 1000 transthoracic needle aspiration biopsies which were performed in 986 patients with 993 chest lesions. Aspiration biopsies were obtained with Westcott needles (20G or 22G) under the fluoroscopic guidance. Final diagnosis was made with operation, bronchoscopy, sputum study, biopsy of other sites and the clinical course of the patient. We analyzed diagnostic yields of aspiration biopsy and the frequency of the complication requiring treatment. The sensitivity was 87.6 % in benign diseases and 95.8 % in malignant diseases. Pneumothorax was the most frequent complication, which required pig-tail catheter insertion in 36 cases or thoracotomy in six cases. In 36 cases, minimal hemoptysis developed which did not require treatments. We obtained relatively high sensitivities of malignant and benign lesions using transthoracic fine needle aspiration biopsy and the frequency of the complications requiring treatment was very low. Transthoracic fine needle aspiration biopsy is a valuable diagnostic method in the thoracic lesions.

  9. Transthoracic fine needle aspiration biopsy: diagnostic rate and complications in 1000 cases

    International Nuclear Information System (INIS)

    Transthoracic fine needle aspiration biopsy is a widely practiced technique in the investigation of the lung and mediastinal masses because of its safety, reliability and accuracy. We report the diagnostic accuracy of the transthoracic fine needle aspiration biopsy and the frequency of its complications which required treatment. We analyzed 1000 transthoracic needle aspiration biopsies which were performed in 986 patients with 993 chest lesions. Aspiration biopsies were obtained with Westcott needles (20G or 22G) under the fluoroscopic guidance. Final diagnosis was made with operation, bronchoscopy, sputum study, biopsy of other sites and the clinical course of the patient. We analyzed diagnostic yields of aspiration biopsy and the frequency of the complication requiring treatment. The sensitivity was 87.6 % in benign diseases and 95.8 % in malignant diseases. Pneumothorax was the most frequent complication, which required pig-tail catheter insertion in 36 cases or thoracotomy in six cases. In 36 cases, minimal hemoptysis developed which did not require treatments. We obtained relatively high sensitivities of malignant and benign lesions using transthoracic fine needle aspiration biopsy and the frequency of the complications requiring treatment was very low. Transthoracic fine needle aspiration biopsy is a valuable diagnostic method in the thoracic lesions

  10. Fabrication of Microbeads with a Controllable Hollow Interior and Porous Wall Using a Capillary Fluidic Device

    OpenAIRE

    Choi, Sung-Wook; Zhang, Yu; Xia, Younan

    2009-01-01

    Poly(d,l-lactide-co-glycolide) (PLGA) microbeads with a hollow interior and porous wall are prepared using a simple fluidic device fabricated with PVC tubes, glass capillaries, and a needle. Using the fluidic device with three flow channels, uniform water-in-oil-in-water (W-O-W) emulsions with a single inner water droplet can be achieved with controllable dimensions by varying the flow rate of each phase. The resultant W-O-W emulsions evolve into PLGA microbeads with a hollow interior and por...

  11. have a hollow leg

    Institute of Scientific and Technical Information of China (English)

    周立

    2003-01-01

    英语对话 A:We must prevent our family members from getting involved with drugs, really. B:That’s a sure thing.We must make sure that they never involve them- selves with that. A:By the way,does your husband drink a lot? B:Yeah.That’s the only thing that keeps worrying me.And he often boasts that he has a hollow leg and nobody can drink him under the ta- ble.

  12. Hollow Maxillary Complete Denture

    OpenAIRE

    Radke, Usha; Mundhe, Darshana

    2011-01-01

    Residual ridge resorption is the reduction in size of the bony ridge under the mucoperiosteum. The resorption occurs at a faster rate in mandibular arch as compared to the maxillary arch; but severely atrophic maxillae with large interridge distance often pose a clinical challenge during fabrication of a successful maxillary complete denture. This clinical report describes a simple technique of fabricating a hollow maxillary complete denture in a patient with resorbed maxillary and mandibular...

  13. Calcium phosphate in catheter encrustation.

    Science.gov (United States)

    Cox, A J; Harries, J E; Hukins, D W; Kennedy, A P; Sutton, T M

    1987-02-01

    Encrusted catheters from nine female patients were the source of samples of deposits which were examined by X-ray diffraction, atomic absorption spectroscopy, infra-red spectroscopy and extended X-ray absorption fine structure (EXAFS) spectroscopy. In eight samples the only crystalline phase which could be clearly distinguished by X-ray diffraction was ammonium magnesium orthophosphate hexahydrate, NH4MgPO4 X 6H2O, which occurs naturally as the mineral struvite. However, atomic absorption spectroscopy revealed an appreciable concentration of calcium in all samples. Calcium phosphates have previously been detected in catheter deposits. Infra-red and EXAFS spectra were consistent with the calcium phosphate being present as a poorly crystalline hydroxyapatite. Thus the deposits appear to consist of a mixture of crystalline struvite and a form of hydroxyapatite which is not fully crystalline. PMID:3030487

  14. Needle stick injuries in a tertiary care hospital

    Directory of Open Access Journals (Sweden)

    Jayanth S

    2009-01-01

    Full Text Available Background: Accidental needle stick injuries (NSIs are an occupational hazard for healthcare workers (HCWs. A recent increase in NSIs in a tertiary care hospital lead to a 1-year review of the pattern of injuries, with a view to determine risk factors for injury and potential interventions for prevention. Methods: We reviewed 1-year (July 2006-June 2007 of ongoing surveillance of NSIs. Results: The 296 HCWs reporting NSIs were 84 (28.4% nurses, 27 (9.1% nursing interns, 45 (21.6% cleaning staff, 64 (21.6% doctors, 47 (15.9% medical interns and 24 (8.1% technicians. Among the staff who had NSIs, 147 (49.7% had a work experience of less than 1 year ( P < 0.001. The devices responsible for NSIs were mainly hollow bore needles ( n = 230, 77.7%. In 73 (24.6% of the NSIs, the patient source was unknown. Recapping of needles caused 25 (8.5% and other improper disposal of the sharps resulted in 55 (18.6% of the NSIs. Immediate post-exposure prophylaxis for HCWs who reported injuries was provided. Subsequent 6-month follow-up for human immunodeficiency virus showed zero seroconversion. Conclusion: Improved education, prevention and reporting strategies and emphasis on appropriate disposal are needed to increase occupational safety for HCWs.

  15. Transhepatic venous catheters for hemodialysis

    OpenAIRE

    Mohamed El Gharib; Gamal Niazi; Waleed Hetta; Yahya Makkeyah

    2014-01-01

    Purpose: To describe our experience with the technique of transhepatic venous access for hemodialysis and to evaluate its functionality and complications. Patients and methods: From March 2012 till October 2012, 23 patients with age ranging from 12 to 71 years old having end-stage renal disease (ESRD) were included in our study and were subjected to transhepatic venous catheter insertion. In 21 patients there were not any remaining patent peripheral venous accesses. In 2 patients there wer...

  16. Optimization of dialysis catheter function.

    Science.gov (United States)

    Gallieni, Maurizio; Giordano, Antonino; Rossi, Umberto; Cariati, Maurizio

    2016-03-01

    Central venous catheters (CVCs) are essential in the management of hemodialysis patients, but they also carry unintended negative consequences and in particular thrombosis and infection, adversely affecting patient morbidity and mortality. This review will focus on the etiology, prevention, and management of CVC-related dysfunction, which is mainly associated with inadequate blood flow. CVC dysfunction is a major cause of inadequate depuration. Thrombus, intraluminal and extrinsic, as well as fibrous connective tissue sheath (traditionally indicated as fibrin sheath) formation play a central role in establishing CVC dysfunction. Thrombolysis with urokinase or recombinant tissue plasminogen activator (rTPA) can be undertaken in the dialysis unit, restoring adequate blood flow in most patients, preserving the existing catheter, and avoiding an interventional procedure. If thrombolytics fail, mainly because of the presence of fibrous connective tissue sheath, catheter exchange with fibrin sheath disruption may be successful and preserve the venous access site. Prevention of CVC dysfunction is important for containing costly pharmacologic and interventional treatments, which also affect patients' quality of life. Prevention is based on the use of anticoagulant and/or thrombolytic CVC locks, which are only partially effective. Chronic oral anticoagulation with warfarin has also been proposed, but its use for this indication is controversial and its overall risk-benefit profile has not been clearly established. PMID:26951903

  17. Real-Time 3-Dimensional Ultrasound-Assisted Infraclavicular Brachial Plexus Catheter Placement: Implications of a New Technology

    Directory of Open Access Journals (Sweden)

    Steven R. Clendenen

    2010-01-01

    Full Text Available Background. There are a variety of techniques for targeting placement of an infraclavicular blockade; these include eliciting paresthesias, nerve stimulation, and 2-dimensional (2D ultrasound (US guidance. Current 2D US allows direct visualization of a “flat” image of the advancing needle and neurovascular structures but without the ability to extensively analyze multidimensional data and allow for real-time manipulation. Three-dimensional (3D ultrasonography has gained popularity and usefulness in many clinical specialties such as obstetrics and cardiology. We describe some of the potential clinical applications of 3D US in regional anesthesia. Methods. This case represents an infraclavicular catheter placement facilitated by 3D US, which demonstrates 360-degree spatial relationships of the entire anatomic region. Results. The block needle, peripheral nerve catheter, and local anesthetic diffusion were observed in multiple planes of view without manipulation of the US probe. Conclusion. Advantages of 3D US may include the ability to confirm correct needle and catheter placement prior to the injection of local anesthetic. The spread of local anesthetic along the length of the nerve can be easily observed while manipulating the 3D images in real-time by simply rotating the trackball on the US machine to provide additional information that cannot be identified with 2D US alone.

  18. Flush Foley's catheter: The most easy way

    OpenAIRE

    Vijay P. Agrawal

    2013-01-01

    Introduction: Foley catheters are used for monitoring urine output in anesthetized patients, comatose patients, incontinent patients, acute urinary retention, paralysed patients, trauma patients, urethral surgeries, ureterectomy, kidney disease, before and after cesarean sections etc. When a Foley catheter becomes clogged, it can cause various complications. For which it is flushed or replaced.Objectives: To find a simple way to flush a Foleys catheter.Material & Methods: Patient was expl...

  19. Reuse of catheters for angiography. 2. Contribution

    International Nuclear Information System (INIS)

    The reuse of sterile medical devices designated for single use is a controversal practice, known to be performed in many countries. As far as catheters for angiography are concerned, various methods for cleaning and sterilisation are in use. However, interactions of detergents and ethylene oxide used in reprocessing with polyethylene materials of the catheters have not been investigated systematically. This paper presents a physico-chemical characterisation of common angiographic catheters. The interaction of polyethylene and ethylene oxide is examined. (orig.)

  20. NRGTM RF powered transseptal needle: a useful technique for transcatheter atrial septostomy and Fontan fenestration: report of three cases

    Directory of Open Access Journals (Sweden)

    Tevfik Karagöz

    2014-10-01

    Full Text Available Transseptal puncture (TSP is a frequently performed procedure for gaining access to the left atrium for catheter ablation, hemodynamic assessment of the left heart, left ventricular assist device implantation, percutaneous left atrial appendage closure or mitral valvuloplasty during childhood and adulthood. The standard technique for transseptal puncture applies mechanical pressure on the fossa ovalis with a Brockenbrough needle. However, this method is not feasible when the fossa ovalis is thick and aneurysmatic. In such patients, the radiofrequency ablation energy systems can be offered as a better alternative for TSP. Here, we aimed to demonstrate the outcome of transseptal puncture performed with an NRGTM RF powered transseptal needle in three patients.

  1. Hollow vortices and minimal surfaces

    OpenAIRE

    Traizet, Martin

    2015-01-01

    We consider an overdetermined elliptic problem known as the hollow vortex problem. We prove that the solutions to this problem are in 1:1 correspondence with minimal graphs bounded by horizontal symmetry lines. We use this correspondence to give various examples of domains with hollow vortices.

  2. Audit of catheter urine culture requests.

    OpenAIRE

    Manek, N; Napier Rees, E

    1992-01-01

    An audit to assess the appropriateness of catheter urine culture requests was carried out for a period of one month. The requests were followed up by members of the Infection Control Team at ward level. The laboratory report had no impact on the removal of the catheter in asymptomatic or symptomatic patients, although the reports did aid antibiotic prescribing in symptomatic patients.

  3. Audit of catheter urine culture requests.

    Science.gov (United States)

    Manek, N; Napier Rees, E

    1992-01-01

    An audit to assess the appropriateness of catheter urine culture requests was carried out for a period of one month. The requests were followed up by members of the Infection Control Team at ward level. The laboratory report had no impact on the removal of the catheter in asymptomatic or symptomatic patients, although the reports did aid antibiotic prescribing in symptomatic patients. PMID:1740523

  4. Soft thrombus formation in radiofrequency catheter ablation

    NARCIS (Netherlands)

    Demolin, JM; Eick, OJ; Munch, K; Koullick, E; Nakagawa, H; Wittkampf, FHM

    2002-01-01

    During RF catheter ablation, local temperature elevation can result in coagulum formation on the ablation electrode, resulting in impedance rise. A recent study has also demonstrated the formation of a so-called soft thrombus during experimental ablations. This deposit poorly adhered to the catheter

  5. Catheter-Associated Urinary Tract Infections

    Science.gov (United States)

    ... Top of page What is a urinary tract infection? A urinary tract infection (UTI) is an infection that involves ... page What is a catheter-associated urinary tract infection (CAUTI)? A catheter-associated urinary tract infection (CAUTI) occurs when germs (usually bacteria) ...

  6. Attitudes Towards Catheter Ablation for Atrial Fibrillation

    DEFF Research Database (Denmark)

    Vadmann, Henrik; Pedersen, Susanne S; Nielsen, Jens Cosedis;

    2015-01-01

    BACKGROUND: Catheter ablation for atrial fibrillation (AF) is an important but expensive procedure that is the subject of some debate. Physicians´ attitudes towards catheter ablation may influence promotion and patient acceptance. This is the first study to examine the attitudes of Danish...

  7. Fabrication process for tall, sharp, hollow, high aspect ratio polymer microneedles on a platform

    International Nuclear Information System (INIS)

    This paper reports on a new lithographic process for fabricating arrays of tall, high aspect ratio (defined as height/wall thickness), hollow, polymer microneedles on a platform. The microneedles feature a high sharpness (down to 3 µm tip radius) and aspect ratio (>65) which is a factor 2 and 4 better than the state of the art, respectively. The maximum achievable needle shaft length is over 1 mm. The improved performance was obtained by using an anisotropically patterned silicon substrate covered with an antireflective layer as mold for the needle tip and an optimized SU-8 lithographic process. Furthermore, a platform containing liquid feedthroughs holding an arbitrary number of needles out of plane can be manufactured with only one additional process step. The high aspect ratio microneedles undergo failure at the critical load of around 230 mN in the case of 1 mm long hollow needles with triangular cross section and a base of 175 µm. Penetration into human skin is demonstrated as well. (paper)

  8. Development of Bend Sensor for Catheter Tip

    Science.gov (United States)

    Nagano, Yoshitaka; Sano, Akihito; Fujimoto, Hideo

    Recently, a minimally invasive surgery which makes the best use of the catheter has been becoming more popular. In endovascular coil embolization for a cerebral aneurysm, the observation of the catheter's painting phenomenon is very important to execute the appropriate manipulation of the delivery wire and the catheter. In this study, the internal bend sensor which consists of at least two bending enhanced plastic optical fibers was developed in order to measure the curvature of the catheter tip. Consequently, the painting could be more sensitively detected in the neighborhood of the aneurysm. In this paper, the basic characteristics of the developed sensor system are described and its usefulness is confirmed from the comparison of the insertion force of delivery wire and the curvature of catheter tip in the experiment of coil embolization.

  9. Needle-Stick Injury and Medical Students' Knowledge

    Directory of Open Access Journals (Sweden)

    Shahin Gasemi

    2012-09-01

    Full Text Available Health-care worker's contamination was noticed with discovery of blood-borne pathogens in the late 1980's. The main way of this transmission is via hollow intravascular needles, although other sharp instruments are also important [1]. Sixty blood-borne pathogens have been reported until now which contain 26 kinds of viruses, 18 kinds of bacteria/ rickettsias, 13 kinds of parasites and 3 different fungi. However, Hepatitis B, C and HIV viruses responsible for the majority of occupational transmission [2]. The risk of this transmission in Hepatitis B (30%, Hepatitis C (1.8% and HIV (0.3% depend on patient's viral load and the amount of blood that has been transmitted from patient to health-care worker [3].

  10. Evaluation of a novel Seldinger-needle for computed tomography guided interventions: initial experiences

    International Nuclear Information System (INIS)

    To evaluate a new Seldinger puncture device for computed tomography-guided interventions under difficult conditions, to analyze applicability, and to investigate assets and drawbacks. From November 2007 to March 2008, we performed CT-guided interventions in 16 patients (7 women, 9 men; mean age 62 years old) using a new 20G-Seldinger needle (Sika-Med, Wiehl, Germany). This novel needle serves as a guide for many different interventional devices due to a guide wire welded on the proximal needle end. It allows continuous application of anesthesia via four tiny holes at the distal needle end until the region of interest is reached. Each intervention was subject to difficult interventional conditions. The indications for intervention were drainage (n = 7), Trucut biopsy of tumor (n = 8) and radiofrequency ablation (n = 1). Handling, success, advantages, drawbacks, complications and patient tolerance were noted after each procedure. A pain scale from 1 - 10 was used to grade the pain level during the intervention. All interventions were performed successfully and no severe complications were observed. Patient tolerance was very good resulting in a mean pain score of 2 ± 1. Regions with dangerous and difficult access were successfully reached with the new Seldinger needle in 15 of 16 cases by dilatation of the puncture tract and continuous administration of local anesthesia via the system. Furthermore, different devices such as Trucut systems and a drainage catheter were able to be inserted without complication via the needle. With a proximal removable luer-lock connection, liquid material was able to be aspirated in six cases. Under difficult interventional conditions, the use of a Seldinger needle as a reliable technique for CT-guided interventions can provide a safe and successful procedure. (orig.)

  11. MRI-guided prostate focal laser ablation therapy using a mechatronic needle guidance system

    Science.gov (United States)

    Cepek, Jeremy; Lindner, Uri; Ghai, Sangeet; Davidson, Sean R. H.; Trachtenberg, John; Fenster, Aaron

    2014-03-01

    Focal therapy of localized prostate cancer is receiving increased attention due to its potential for providing effective cancer control in select patients with minimal treatment-related side effects. Magnetic resonance imaging (MRI)-guided focal laser ablation (FLA) therapy is an attractive modality for such an approach. In FLA therapy, accurate placement of laser fibers is critical to ensuring that the full target volume is ablated. In practice, error in needle placement is invariably present due to pre- to intra-procedure image registration error, needle deflection, prostate motion, and variability in interventionalist skill. In addition, some of these sources of error are difficult to control, since the available workspace and patient positions are restricted within a clinical MRI bore. In an attempt to take full advantage of the utility of intraprocedure MRI, while minimizing error in needle placement, we developed an MRI-compatible mechatronic system for guiding needles to the prostate for FLA therapy. The system has been used to place interstitial catheters for MRI-guided FLA therapy in eight subjects in an ongoing Phase I/II clinical trial. Data from these cases has provided quantification of the level of uncertainty in needle placement error. To relate needle placement error to clinical outcome, we developed a model for predicting the probability of achieving complete focal target ablation for a family of parameterized treatment plans. Results from this work have enabled the specification of evidence-based selection criteria for the maximum target size that can be confidently ablated using this technique, and quantify the benefit that may be gained with improvements in needle placement accuracy.

  12. A novel needle-based miniature x-ray generating system

    International Nuclear Information System (INIS)

    The basic concept, design and performance of a novel needle-based x-ray system for medical applications are reported. The main principle of the system is based on a two-stage production of x-rays. The system comprises a conventional x-ray tube with an Ag anode, any known type of conditioning optics and a 2.2 mm diameter hollow needle with an interchangeable Mo target. The target can be moved along the needle axis and rotated around the needle axis. The needle x-ray device allows for adjustment in energy and flux intensity of the x-rays emitted by the target. The depth dependence of the intensity, dose rate as well as spatial and energy distribution of the radiation emitted by the target have been experimentally measured. The depth dose rate results have been compared with theoretical calculations using a Monte Carlo simulation of the x-ray production process. These studies have experimentally confirmed that the concept of this x-ray system is correct. Further improvement of the device can increase the dose rate up to the levels required for clinical applications

  13. Needle biopsy of the breast.

    Science.gov (United States)

    Millis, R R

    1984-01-01

    Recently, there has been a considerable increase in the use of both fine-needle aspiration biopsy (aspiration cytology) and tissue-core needle biopsy of the breast. In patients with suspected breast cancer, needle biopsy is frequently used to confirm the diagnosis before treatment is planned. This allows a more thoughtful approach to the patient and full screening for possible metastatic disease prior to definitive surgery. Needle biopsy techniques are simple, rapid, can be performed in the doctor's office, and save time, equipment, and hospital beds. Complications are few. Aspiration cytology has the advantage that it is quick to perform, the preparation can be examined almost immediately and, in the event of an unsatisfactory smear, the procedure can be repeated. However, the diagnosis is based on purely cytological evaluation, and the information obtained is somewhat limited. Reported accuracy rates range from 42 to 96%. False positive reports are rare but have occurred in most centers, and a high degree of accuracy will only be obtained by experienced practitioners. Tissue-core needle biopsy has the advantage that the diagnosis is based on histopathological assessment, but the procedure is slightly more time consuming, is more traumatic for the patient, and the equipment is more expensive. Accuracy rates range from 67 to 98.5%. During the past 4 years, 329 tissue-core (Tru-Cut) biopsies have been performed in the Guy's Hospital Breast Unit, with an accuracy rate of 83% in the diagnosis of carcinoma. The procedure has been acceptable to most patients, and complications have been minimal. Studies comparing the use of aspiration cytology and tissue-core needle biopsy in the diagnosis of mammary carcinoma have produced variable results. Both methods have advantages and disadvantages, and the choice of technique must depend on the clinical situation and the preferences and skills of the practitioners involved in the management of the patient. PMID:6377049

  14. Birefringent hollow core fibers

    DEFF Research Database (Denmark)

    Roberts, John

    2007-01-01

    applications, and places emphasis on the development of polarization maintaining (PM) HC-PCF. The polarization cross-coupling characteristics of PM HC-PCF are very different from those of conventional PM fibers. The former fibers have the advantage of suffering far less from stress-field fluctuations, but the......Hollow core photonic crystal fiber (HC-PCF), fabricated according to a nominally non-birefringent design, shows a degree of un-controlled birefringence or polarization mode dispersion far in excess of conventional non polarization maintaining fibers. This can degrade the output pulse in many...... increased overlap between the polarization modes at the glass interfaces. The interplay between these effects leads to a wavelength for optimum polarization maintenance, lambda(PM), which is detuned from the wavelength of highest birefringence. By a suitable fiber design involving antiresonance of the core...

  15. Magnetic needles and superparamagnetic cells

    International Nuclear Information System (INIS)

    Superparamagnetic nanoparticles can be attached in great numbers to pathogenic cells using specific antibodies so that the magnetically-labeled cells themselves become superparamagnets. The cells can then be manipulated and drawn out of biological fluids, as in a biopsy, very selectively using a magnetic needle. We examine the origins and uncertainties in the forces exerted on magnetic nanoparticles by static magnetic fields, leading to a model for trajectories and collection times of dilute superparamagnetic cells in biological fluids. We discuss the design and application of such magnetic needles and the theory of collection times. We compare the mathematical model to measurements in a variety of media including blood

  16. Radiological Interventions for Correction of Central Venous Port Catheter Migrations

    International Nuclear Information System (INIS)

    The purpose of the study is to evaluate radiological-interventional central venous port catheter corrections in migrated/malpositioned catheter tips. Thirty patients with migrated/malpositioned port catheter tips were included in this retrospective analysis. To visualize the catheter patency, a contrast-enhanced port catheter series was performed, followed by transfemoral port catheter correction with various 5F angiographic catheters (pigtail, Sos Omni), goose-neck snare, or combinations thereof. One patient showed spontaneous reposition of the catheter tip. In 27 of 29 patients (93%), radiological-interventional port catheter correction was successful. In two patients, port catheter malposition correction was not possible because of the inability to catch either the catheter tip or the catheter in its course, possibly due to fibrin sheath formation with attachment of the catheter to the vessel wall. No disconnection or port catheter dysfunction was observed after correction. In migrated catheter tips, radiological-interventional port catheter correction is a minimally invasive alternative to port extraction and reimplantation. In patients with a fibrin sheath and/or thrombosis, port catheter correction is often more challenging

  17. Radiological Interventions for Correction of Central Venous Port Catheter Migrations

    International Nuclear Information System (INIS)

    Purpose. The purpose of this study was to evaluate radiological-interventional central venous port catheter corrections in migrated/malpositioned catheter tips. Materials and Methods. Thirty patients with migrated/malpositioned port catheter tips were included in this retrospective analysis. To visualize the catheter patency a contrast-enhanced port catheter series was performed, followed by transfemoral port catheter correction with various 5-F angiographic catheters (pigtail; Sos Omni), gooseneck snares, or combinations thereof. Results. One patient showed spontaneous reposition of the catheter tip. In 27 of 29 patients (93%), radiological-interventional port catheter correction was successful. In two patients port catheter malposition correction was not possible, because of the inability to catch either the catheter tip or the catheter in its course, possibly due to fibrin sheath formation with attachment of the catheter to the vessel wall. No disconnection or port catheter dysfunction was observed after correction. Conclusions. We conclude that in migrated catheter tips radiological-interventional port catheter correction is a minimally invasive alternative to port extraction and reimplantation. In patients with a fibrin sheath and/or thrombosis port catheter correction is often more challenging

  18. Genetics Home Reference: Melnick-Needles syndrome

    Science.gov (United States)

    Skip to main content Your Guide to Understanding Genetic Conditions Enable Javascript for addthis links to activate. ... Conditions Genes Chromosomes & mtDNA Resources Help Me Understand Genetics Home Health Conditions Melnick-Needles syndrome Melnick-Needles ...

  19. Catheter-tip fixation of a percutaneously implanted port-catheter system to prevent dislocation

    International Nuclear Information System (INIS)

    The aim of this study was to evaluate the incidence of catheter tip dislocation in patients with percutaneously implanted port-catheters for hepatic arterial chemotherapy with catheter tip fixation. Forty-seven patients (31 men and 16 women; mean age 66 years) with unresectable advanced liver cancers (primary liver cancer, n=19; metastatic liver cancer, n=28) underwent percutaneously implantable port-catheter system placement with the tip fixed at the gastroduodenal artery with coils and side hole opened at the common hepatic artery. In 39 patients, n-butyl cyanoacrylate (NBCA) mixed with Lipiodol was added for fixation. The position of the side hole after the indwelling port-catheter system was investigated, and the correction method in cases with catheter dislocation was determined. In 2 (25%) of the 8 patients without NBCA fixation, dislocation of the catheter was noted, in contrast to none (0%) of 37 patients with NBCA fixation. Two patients in whom NBCA was used could not undergo long-term intra-arterial chemotherapy because of hepatic arterial thrombotic occlusion which occurred after placement of the indwelling catheter, and were excluded from the evaluation. Fixation of the catheter tip with combined use of coils and NBCA-Lipiodol mixture to the gastroduodenal artery is important to prevent dislocation of the port-catheter system. (orig.)

  20. Autosizing Control Panel for Needle Bearing

    OpenAIRE

    Prof.A.R.Wadhekar,; Ms Jyoti R. Rajput

    2016-01-01

    A needle roller bearing is a bearing which uses small cylindrical rollers. Bearings are used to reduce friction of any rotating surface. Needle bearings have a large surface in contact with the bearing outer surfaces as compared to ball bearings. There is less added clearance(Diameter of the shaft and the diameter of the bearing are different) so they are much compact. The structure consists of a needle cage which contains the needle rollersthemselves and an outer race (The housin...

  1. Dry needling — peripheral and central considerations

    OpenAIRE

    Dommerholt, Jan

    2011-01-01

    Dry needling is a common treatment technique in orthopedic manual physical therapy. Although various dry needling approaches exist, the more common and best supported approach targets myofascial trigger points. This article aims to place trigger point dry needling within the context of pain sciences. From a pain science perspective, trigger points are constant sources of peripheral nociceptive input leading to peripheral and central sensitization. Dry needling cannot only reverse some aspects...

  2. Radiofrequency catheter oblation in atrial flutter

    International Nuclear Information System (INIS)

    Objective: To evaluate the radiofrequency catheter ablation for type I atrial flutter through application of Holo catheter labelling with anatomic imaging localization to ablate the isthmus of IVCTA during complete double-way block. Methods: Eleven cases with type I atrial flutter undergone Holo catheter labelling technique and consecution with conduction time change of coronary venous sinus orifice with-right atrial lower lateral wall pace excitation, were performed with radiofrequency catheter ablation for the isthmus outcoming with complete double-way conduction block. Results: All together 11 cases with 4 of atrial flutter and 7 of sinus rhythm were undergone radiofrequency catheter ablation resulting with double-way conduction block of the isthmus accompanied by prolongation of right atrial conduction time 56.0 ± 2.3 ms and 53.0 ± 4.6 ms respectively. The right atrial excitation appeared to be in clockwise and counter-clockwise of single direction. No recurrence occurred during 3-34 months follow up with only one showing atrial fibrillation. Conclusions: The application of Holo catheter labelling technique with anatomic imaging localization to achieve the double-way conduction block by radiofrequency catheter ablation of TVC-TA isthmus, is a reliable method for treating atrial flutter

  3. 21 CFR 880.5580 - Acupuncture needle.

    Science.gov (United States)

    2010-04-01

    ... in 21 CFR 801.109, (2) Device material biocompatibility, and (3) Device sterility. ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Acupuncture needle. 880.5580 Section 880.5580 Food... § 880.5580 Acupuncture needle. (a) Identification. An acupuncture needle is a device intended to...

  4. [Catheter-associated urinary tract infections].

    Science.gov (United States)

    Liedl, B

    2015-09-01

    In patients with indwelling urethral catheters significant bacteriuria develops within 4 weeks of indwelling time in practically 100% of the cases. Catheter encrustation and obstruction can occur in approximately 40% of patients. Symptomatic ascending urinary tract infections, urethral complications and urolithiasis can occur in significant numbers in the long term. Regular educational and surveillance programs in nursing homes, hospitals and in home care are important to instruct personnel in hygiene procedures, to learn the indications for catheterization, to keep the indwelling time of catheters as short as possible, to detect any complications early and to initiate appropriate diagnostics and therapy by the urologist. PMID:26275988

  5. Catheter meaning for the adolescents in dialysis

    Directory of Open Access Journals (Sweden)

    Liliana Cristina Morales

    2009-12-01

    Full Text Available Goal: Terminal renal failure affects all the person’s life dimensions. The impact of this illness during adolescence is quite dramatic because the adolescent must live with the illness demands and the demands from this crucial developmental stage. Knowledge regarding the impact of the dialysis catheter on the adolescent’s life is spare. Methodology: A phenomenological study was carried out with 8 female and male adolescents that were in dialysis. Findings: The adolescents had to learn to live with the dialysis catheter in their body. The catheter became an obstacle to achieve their identity and deteriorated their physical appearance and peer relationships.

  6. Effect and Safety of Deep Needling and Shallow Needling for Functional Constipation

    OpenAIRE

    Wu, Jiani; Liu, Baoyan; Li, Ning; Sun, Jianhua; Wang, Lingling; Wang, Liping; Cai, Yuying; Ye, Yongming; Liu, Jun; Wang, Yang; Liu, Zhishun

    2014-01-01

    Abstract Aupuncture is widely used for functional constipation. Effect of acupuncture might be related to the depth of needling; however, the evidence is limited. This trial aimed to evaluate the effect and safety of deep needling and shallow needling for functional constipation, and to assess if the deep needling and shallow needling are superior to lactulose. We conducted a prospective, superiority-design, 5-center, 3-arm randomized controlled trial. A total of 475 patients with functional ...

  7. Biomechanical performance of new cardiovascular needles.

    Science.gov (United States)

    Thacker, J G; Ferguson, R E; Rodeheaver, G T; Edlich, R F

    2001-01-01

    Cardiovascular needles are now being manufactured from new stainless steel alloys containing high concentrations of nickel, Surgalloy and Ethalloy. The purpose of this study was to compare the biomechanical performance of a cardiovascular needle made of Surgalloy with a comparably sized needle made of Ethalloy. The parameters of biomechanical performance included sharpness, maintenance of sharpness, resistance to bending, and ductility. Because the biomechanical performance of these needles was remarkably similar, cardiovascular needles made of either the Surgalloy or Ethalloy alloys are recommended for cardiovascular surgery. PMID:11495105

  8. Sterile Fluid Collections in Acute Pancreatitis: Catheter Drainage Versus Simple Aspiration

    International Nuclear Information System (INIS)

    Purpose. To compare the clinical outcome of needle aspiration versus percutaneous catheter drainage of sterile fluid collections in patients with acute pancreatitis. Methods. We reviewed the clinical and imaging data of patients with acute pancreatic fluid collections from 1998 to 2003. Referral for fluid sampling was based on elevated white blood cell count and fevers. Those patients with culture-negative drainages or needle aspirations were included in the study. Fifteen patients had aspiration of 10-20 ml fluid only (group A) and 22 patients had catheter placement for chronic evacuation of fluid (group C). We excluded patients with grossly purulent collections and chronic pseudocysts. We also recorded the number of sinograms and catheter changes and duration of catheter drainage. The CT severity index, Ranson scores, and maximum diameter of abdominal fluid collections were calculated for all patients at presentation. The total length of hospital stay (LOS), length of hospital stay after the drainage or aspiration procedure (LOS-P), and conversions to percutaneous and/or surgical drainage were recorded as well as survival. Results. The CT severity index and acute Ransom scores were not different between the two groups (p = 0.15 and p = 0.6, respectively). When 3 crossover patients from group A to group C were accounted for, the duration of hospitalization did not differ significantly, with a mean LOS and LOS-P of 33.8 days and 27.9 days in group A and 41.5 days and 27.6 days in group C, respectively (p = 0.57 and 0.98, respectively). The 60-day mortality was 2 of 15 (13%) in group A and 2 of 22 (9.1%) in group C. Kaplan-Meier survival curves for the two groups were not significantly different (p 0.3). Surgical or percutaneous conversions occurred significantly more often in group A (7/15, 47%) than surgical conversions in group C (4/22, 18%) (p 0.03). Patients undergoing catheter drainage required an average of 2.2 sinograms/tube changes and kept catheters in for

  9. Antimicrobial-impregnated catheters for the prevention of catheter-related bloodstream infections.

    Science.gov (United States)

    Lorente, Leonardo

    2016-05-01

    Central venous catheters are commonly used in critically ill patients. Such catheterization may entail mechanical and infectious complications. The interest in catheter-related infection lies in the morbidity, mortality and costs that it involved. Numerous contributions have been made in the prevention of catheter-related infection and the current review focuses on the possible current role of antimicrobial impregnated catheters to reduce catheter-related bloodstream infections (CRBSI). There is evidence that the use of chlorhexidine-silver sulfadiazine (CHSS), rifampicin-minocycline, or rifampicin-miconazol impregnated catheters reduce the incidence of CRBSI and costs. In addition, there are some clinical circumstances associated with higher risk of CRBSI, such as the venous catheter access and the presence of tracheostomy. Current guidelines for the prevention of CRBSI recommended the use of a CHSS or rifampicin-minocycline impregnated catheter in patients whose catheter is expected to remain in place > 5 d and if the CRBSI rate has not decreased after implementation of a comprehensive strategy to reduce it. PMID:27152256

  10. Stuck suction catheter in endotracheal tube

    Directory of Open Access Journals (Sweden)

    Monish S Raut

    2015-01-01

    Full Text Available Endotracheal tube (ETT suction is essential to clear secretions so that airway patency can be maintained. Stuck suction catheter in ETT is an uncommon event, and it can be dangerous in patients with difficult airway cases.

  11. Venous port catheter dislocation as an unusual cause of pneumonia

    Directory of Open Access Journals (Sweden)

    Umut Serhat Sanrı

    2014-06-01

    Full Text Available The use of central venous port catheter is a very useful method for long-term therapy in patients with malignancy. Catheter insertion technique and maintenance of equipment is very important to the prevention of catheter-related complications. The most frequent complications are deep venous thrombosis, port infection, catheter obstruction. İn this article, pneumonia occurrence after chemotherapy infusion in a patient who has a completely extravasated central venous port catheter discussed.

  12. Quantification of HIV-1 viral RNA in the blood in needles used for venous puncture in HIV-infected individuals

    Directory of Open Access Journals (Sweden)

    Iris Ricardo Rossin

    2011-12-01

    Full Text Available INTRODUCTION: Occupational HIV infection among healthcare workers is an important issue in exposures involving blood and body fluids. There are few data in the literature regarding the potential and the duration of infectivity of HIV type 1 (HIV-1 in contaminated material under adverse conditions. METHODS: We quantified HIV-1 viral RNA in 25×8mm calibre hollow-bore needles, after punctures, in 25 HIV-1-infected patients selected during the sample collection. All of the patients selected were between the ages of 18 and 55. Five samples were collected from 16 patients: one sample for the immediate quantification of HIV-1 RNA in the plasma and blood samples from the interior of 4 needles to be analyzed at 0h, 6h, 24h, and 72h after collection. In nine patients, another test was carried out in the blood from one additional needle, in which HIV-1 RNA was assessed 168h after blood collection. The method used to assess HIV-1 RNA was nucleic acid sequence-based amplification. RESULTS: Up to 7 days after collection, HIV-1 RNA was detected in all of the needles. The viral RNA remained stable up to 168h, and there were no statistically significant differences among the needle samples. CONCLUSIONS: Although the infectivity of the viral material in the needles is unknown, the data indicate the need to re-evaluate the practices in cases of occupational accidents in which the source is not identified.

  13. An Unusual Complication of Suprapubic Catheter Insertion

    Directory of Open Access Journals (Sweden)

    Krishnan Ananthakrishnan

    2006-01-01

    Full Text Available A patient who had a small bowel mesentery perforation following insertion of a suprapubic catheter (SPC is described. He had no bowel complaints immediately following the procedure, but presented 10 weeks later with insidious onset bowel obstruction due to the kink caused by the catheter. This complication occurred despite cystoscopy control and adequate bladder distension prior to the procedure. This isolated case illustrates the fact that regardless of the ease and frequency of SPC insertion, complications do occur.

  14. Wound catheter techniques for postoperative analgesia

    OpenAIRE

    VINTAR, NELI

    2009-01-01

    Wound catheter technique is a technique of postoperative analgesia in which the surgeon places a catheter to infuse local anesthetic into wounds at the end of the procedure. It can be used in abdominal colorectal surgery or after holecystectomies, was studied after caesarean delivery. It was effective after some orthopaedic procedures such as shoulder and knee surgery, at the donor site in the iliac crest. It can be used in plastic surgery after breast surgery. It is technically efficie...

  15. Rotational fluoroscopy and fine needle antegrade pyelography for determining kidney access in percutaneous nephrostomy

    International Nuclear Information System (INIS)

    Objective: To investigate the clinical value of fine needle antegrade pyelography combined with rotational fluoroscopy in determining the puncture track of percutaneous nephrostomy. Methods: A total of 543 patients with upper ureter calculus had percutaneous nephrostomy guided by C-arm fluoroscopy. After rotating fluoroscopy from anterior to lateral positions, fine needle percutaneous antegrade pyelography was performed under fluoroscopic guidance, which allowed three-dimensional mapping of the calculi, renal pelvis and their relationship. Using the nephroscope to select the optimal skin and calyceal puncture site by a 19G EV needle, the hydrophilic guide wire with or without a catheter was introduced and passed though the ureteric obstruction into the bladder. The punctured track was dilated and a nephrostomy tube was inserted. Results: Successful nephrostomy was performed on 542 patients. The nephrostomy tube was inserted into the ureter or renal pelvis in 539 cases and inserted into renal calices in 3 cases, with complications of renal pelvic tear in 5, pleura injury in 3, mild post-operative hemorrhage in 3 and delayed massive hemorrhage in 1. One patient died of heart failure after nephrolithotomy.. The total stone-free rate was 88% after the first nephrolithotomy. Conclusion: The use of fine needle antegrade pyelography combined with rotational fluoroscopy to determine the kidney access improves the success rate and reduces the incidence of complication. (authors)

  16. Switching a Nanocluster Core from Hollow to Non-hollow

    KAUST Repository

    Bootharaju, Megalamane Siddaramappa

    2016-03-24

    Modulating the structure-property relationship in atomically precise nanoclusters (NCs) is vital for developing novel NC materials and advancing their applications. While promising biphasic ligand-exchange (LE) strategies have been developed primarily to attain novel NCs, understanding the mechanistic aspects involved in tuning the core and the ligand-shell of NCs in such biphasic processes is challenging. Here, we design a single phase LE process that enabled us to elucidate the mechanism of how a hollow NC (e.g., [Ag44(SR)30]4-, -SR: thiolate) converts into a non-hollow NC (e.g., [Ag25(SR)18]-), and vice versa. Our study reveals that the complete LE of the hollow [Ag44(SPhF)30]4- NCs (–SPhF: 4-fluorobenzenethiolate) with incoming 2,4-dimethylbenzenethiol (HSPhMe2) induced distortions in the Ag44 structure forming the non-hollow [Ag25(SPhMe2)18]- by a disproportionation mechanism. While the reverse reaction of [Ag25(SPhMe2)18]- with HSPhF prompted an unusual dimerization of Ag25, followed by a rearrangement step that reproduces the original [Ag44(SPhF)30]4-. Remarkably, both the forward and the backward reactions proceed through similar size intermediates that seem to be governed by the boundary conditions set by the thermodynamic and electronic stability of the hollow and non-hollow metal cores. Furthermore, the resizing of NCs highlights the surprisingly long-range effect of the ligands which are felt by atoms far deep in the metal core, thus opening a new path for controlling the structural evolution of nanoparticles.

  17. Hollow nanotubular toroidal polymer microrings

    Science.gov (United States)

    Lee, Jiyeong; Baek, Kangkyun; Kim, Myungjin; Yun, Gyeongwon; Ko, Young Ho; Lee, Nam-Suk; Hwang, Ilha; Kim, Jeehong; Natarajan, Ramalingam; Park, Chan Gyung; Sung, Wokyung; Kim, Kimoon

    2014-02-01

    Despite the remarkable progress made in the self-assembly of nano- and microscale architectures with well-defined sizes and shapes, a self-organization-based synthesis of hollow toroids has, so far, proved to be elusive. Here, we report the synthesis of polymer microrings made from rectangular, flat and rigid-core monomers with anisotropically predisposed alkene groups, which are crosslinked with each other by dithiol linkers using thiol-ene photopolymerization. The resulting hollow toroidal structures are shape-persistent and mechanically robust in solution. In addition, their size can be tuned by controlling the initial monomer concentrations, an observation that is supported by a theoretical analysis. These hollow microrings can encapsulate guest molecules in the intratoroidal nanospace, and their peripheries can act as templates for circular arrays of metal nanoparticles.

  18. Hollow sphere ceramic particles for abradable coatings

    International Nuclear Information System (INIS)

    A hollow sphere ceramic flame spray powder is disclosed. The desired constituents are first formed into agglomerated particles in a spray drier. Then the agglomerated particles are introduced into a plasma flame which is adjusted so that the particles collected are substantially hollow. The hollow sphere ceramic particles are suitable for flame spraying a porous and abradable coating. The hollow particles may be selected from the group consisting of zirconium oxide and magnesium zirconate

  19. Strategies for the control of catheter encrustation.

    Science.gov (United States)

    Stickler, D J; Evans, A; Morris, N; Hughes, G

    2002-06-01

    Two general strategies have been adopted to develop catheter materials that resist encrustaion by bacterial biofilms: (a) the incorporation of antimicrobial agents into the polymers and (b) the production of materials with surface properties which prevent the adherence of bacterial cells. Our experience to develop non-adherent surfaces which abstracts design from nature is reported. Compounds based on 2-methacryloloxyethylphosphorylcholine co-polymerised with long-chain alkyl methacrylates have been produced which have structural and surface properties similar to those of the outer membranes of erythrocytes. These PC-coatings have been applied onto catheter base materials where they produce polar surfaces that are extremely hydrophilic. In experiments using a laboratory model of the catheterised bladder we found that the PC-coatings did not reduce colonisation of latex or silicone catheters by crystalline Proteus mirabilis biofilm. There were no significant difference between the amounts of calcium and magnesium salts deposited on coated and non-coated catheters. In a further set of experiments the PC-coatings did not significantly increase the mean times for which catheters drained freely. In a parallel clinical study, the performance of PC-coated ureteral stents was investigated. Scanning electron microscopy and bacteriological analysis on 44 PC-coated stents that had been implanted in patients for 12-week periods and 28 control stents suggested that the PC-coated devices were less vulnerable to encrustation and colonisation by bacterial biofilm than normal stents. It was of interest that in contrast to encrusted catheters, urease producing species such as P. mirabilis were rarely isolated from the stents. The main organisms colonising the stents were enterococci and coagulase-negative staphylococci. These results suggest that the mechanisms of catheter and stent encrustation may be different and require different strategies for control. PMID:12135840

  20. Hollow waveguide for urology treatment

    Science.gov (United States)

    Jelínková, H.; Němec, M.; Koranda, P.; Pokorný, J.; Kőhler, O.; Drlík, P.; Miyagi, M.; Iwai, K.; Matsuura, Y.

    2010-02-01

    The aim of our work was the application of the special sealed hollow waveguide system for the urology treatment - In our experimental study we have compared the effects of Ho:YAG (wavelength 2100 nm) and Er:YAG (wavelength 2940 nm) laser radiation both on human urinary stones (or compressed plaster samples which serve as a model) fragmentation and soft ureter tissue incision in vitro. Cyclic Olefin Polymer - coated silver (COP/Ag) hollow glass waveguides with inner and outer diameters 700 and 850 μm, respectively, were used for the experiment. To prevent any liquid to diminish and stop the transmission, the waveguide termination was utilized.

  1. Stereotactic catheter placement for Ommaya reservoirs.

    Science.gov (United States)

    Kennedy, Benjamin C; Brown, Lauren T; Komotar, Ricardo J; McKhann, Guy M

    2016-05-01

    Ommaya reservoirs are an important surgical therapy for the chronic intrathecal administration of chemotherapy for patients with leptomeningeal carcinomatosis. Surgical accuracy is paramount in these patients with typically normal sized ventricles, and may be improved with stereotactic guidance. This paper aimed to review a large series of stereotactic Ommaya catheter placements, examining accuracy and complications. We conducted a retrospective review of 109 consecutive adult patients who underwent stereotactic Ommaya catheter placement for leptomeningeal carcinomatosis or central nervous system lymphoma at Columbia University Medical Center, USA, from 1998-2013. The rate of accurate placement in the ventricular system was 99%, with the only poor catheter position due to post-placement migration. The rate of peri-operative complications was 6.4%. Hemorrhagic complications occurred in patients with thrombocytopenia or therapeutic anti-coagulation pre-operatively or during the post-operative period. Use of stereotaxy for catheter placement of Ommaya reservoirs is safe and effective, and should be considered when placing a catheter into non-hydrocephalic ventricles. PMID:26778516

  2. Catheter-associated urinary tract infections.

    Science.gov (United States)

    Liedl, B

    2001-01-01

    In the past few years it has been clearly demonstrated that the concept of bacterial biofilm production permits an understanding and provides some explanation of the pathogenesis, diagnosis and treatment of catheter-associated urinary tract infections. This concept describes the colonization of catheter surfaces and the movement of bacteria against the urinary flow. It explains the antibacterial resistance of these matrix-enclosed sessile populations of bacteria. The catheter encrustation can be observed as mineralizing bacterial biofilm. The differentiation in swarming cells exposing a much higher activity of the enzyme urease is responsible for the predominant role of Proteus mirabilis in obstructing encrustations. The guidelines for the prevention of catheter-associated urinary tract infections were developed over the past decades by clinicians and are still valid. They can now be better understood taking into consideration these new theories. As overuse of urethral catheters and non-compliance of their recommended use are still apparent, educational and surveillance programmes are needed to help maintain good standards of care. PMID:11148750

  3. How to manage an arterial catheter.

    Science.gov (United States)

    Parry, Andrew; Higginson, Ray

    2016-03-16

    Rationale and key points This article provides nurses with information on the safe and effective use and management of arterial catheters, the gold standard for accurate blood pressure measurement and routine serial blood gas sampling in critical care. Arterial catheters are used when real-time blood pressure monitoring is required, such as when there is a risk of significant blood loss. ▶ Arterial catheters provide real-time blood pressure monitoring, enabling rapid identification of changes in blood pressure and guiding fluid resuscitation. ▶ Arterial catheters can be used to take blood samples without having to perform multiple arterial or venous punctures. Reflective activity Clinical skills articles can help update your practice and ensure it remains evidence based. Apply this article to your practice. Reflect on and write a short account of: 1. How this article will change your practice when managing a patient with an arterial catheter. 2. Any further learning needs you have identified. Subscribers can upload their reflective accounts at: rcni.com/portfolio . PMID:26982866

  4. Usefulness of Core Needle Biopsy for Thyroid Nodules with Macrocalcifications: Comparison with Fine-Needle Aspiration

    OpenAIRE

    Yi, Kyung Sik; Kim, Ji-Hoon; Na, Dong Gyu; Seo, Hyobin; Min, Hye Sook; Won, Jae-Kyung; Yun, Tae Jin; Ryoo, Inseon; Kim, Su Chin; Choi, Seung Hong; Sohn, Chul-Ho

    2015-01-01

    Background: This study was performed to determine the benefits of core needle biopsy (CNB), as compared with fine-needle aspiration (FNA), for the diagnosis of thyroid nodules with macrocalcifications.

  5. Extraordinary Vessels Needling for Vascular Dementia

    Institute of Scientific and Technical Information of China (English)

    YU Jin; LAI Xin-sheng; HUANG Qiu-tang; XIAO Yuan-chun

    2003-01-01

    Purpose To observe the clinical efficacy of extraordinary vessels needling in treating vascular dementia. Method 39 cases vascular dementia were treated by acupoints selected from the eight extraordinary meridians and the time needling techniques such as eight methods of spiritual turtle, in accordance with time period and pattern identifition. Results 2 cases were cured, 30 cases improved and 7 cases failed; the total effective rate was 82.1%. Conclusion Extraordinary vessels needling has positive effects in treating vascular dementia.

  6. Exploration of New Electroacupuncture Needle Material

    OpenAIRE

    Sanghun Lee; Gwang-Ho Choi; Chang Hoon Lee; Yu Kyoung Kim; Saebhom Lee; Sungjin Cho; Sunhee Yeon; Sun-Mi Choi; Yeon-Hee Ryu

    2012-01-01

    Background. Electro Acupuncture (EA) uses the acupuncture needle as an electrode to apply low-frequency stimulation. For its safe operation, it is essential to prevent any corrosion of the acupuncture needle. Objective. The aim of this study is to find an available material and determine the possibility of producing a standard EA needle that is biocompatible. Methods. Biocompatibility was tested by an MTT assay and cytotoxicity testing. Corrosion was observed with a scanning electron microsco...

  7. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  8. Hollow waveguide cavity ringdown spectroscopy

    Science.gov (United States)

    Dreyer, Chris (Inventor); Mungas, Greg S. (Inventor)

    2012-01-01

    Laser light is confined in a hollow waveguide between two highly reflective mirrors. This waveguide cavity is used to conduct Cavity Ringdown Absorption Spectroscopy of loss mechanisms in the cavity including absorption or scattering by gases, liquid, solids, and/or optical elements.

  9. Hollow cathode hydrogen ion source

    International Nuclear Information System (INIS)

    High current density ion sources have been used to heat plasmas in controlled thermonuclear reaction experiments. High beam currents imply relatively high emission currents from cathodes which have generally taken the form of tungsten filaments. This paper describes a hydrogen ion source which was primarily developed to assess the emission current capability and design requirements for hollow cathodes for application in neutral injection devices. The hydrogen source produced ions by electron bombardment via a single hollow cathode. Source design followed mercury ion thruster technology, using a weak magnetic field to enhance ionization efficiency. A 1.3-cm diameter hollow cathode using a low work function material dispenser performed satisfactorily over a discharge current range of 10 to 90 A. Cylindrical probe measurements taken without ion extraction indicate maximum ion number densities on the order of 1012 cm-3. Discharge durations ranged from 30 seconds to continuous operation. Tests with beam extraction at 2.5 keV and 30 A discharge current yield average ion beam current densities of 0.1 A cm-2 over a 5-cm extraction diameter. Results of this study can be used to supply the baseline information needed to scale hollow cathodes for operation at discharge currents of hundreds of amperes using distributed cathodes

  10. Tetrahedral mesh for needle insertion

    OpenAIRE

    Syvertsen, Rolf Anders

    2007-01-01

    This is a Master’s thesis in how to make a tetrahedral mesh for use in a needle insertion simulator. It also describes how it is possible to make the simulator, and how to improve it to make it as realistic as possible. The medical simulator uses a haptic device, a haptic scene graph and a FEM for realistic soft tissue deformation and interaction. In this project a tetrahedral mesh is created from a polygon model, and then the mesh has been loaded into the HaptX haptic scene graph. The object...

  11. Impact of short-term hemodialysis catheters on the central veins: a catheter venographic study

    Energy Technology Data Exchange (ETDEWEB)

    Oguzkurt, Levent E-mail: loguzkurt@yahoo.com; Tercan, Fahri; Torun, Dilek; Yildirim, Tuelin; Zuemruetdal, Ayseguel; Kizilkilic, Osman

    2004-12-01

    Objective: To determine the incidence of pericatheter sleeve formation, thrombus formation, and stenosis of the central veins in hemodialysis patients with temporary catheters. Methods and material: In this prospective study, 57 patients (40 males, 17 females) with temporary dialysis catheters had catheter venography by pulling back the catheter just before removal. Patient's age range was 25-87 years (mean age, 51 years). The venographic studies were evaluated for pericatheter sleeve formation, thrombus formation, and stenosis of the brachiocephalic vein (BCV) and the superior vena cava (SVC). The IJV could only be evaluated if there was adequate filling during contrast administration. In a subgroup of patients who had had only right IJV or only right SCV catheters, impact of these catheters on the central veins was compared. Results: The catheter location was right internal jugular vein (IJV) in 26 cases, right subclavian vein (SCV) in 27 cases, left IJV in 1 case, and left SCV in 3 cases. Thirty-two patients (56%) had had only one temporary catheter and the rest had had more than one inserted. The mean dwell time for the catheters was 21 days (range 7-59 days). A pericatheter sleeve was detected on venography in 32 (56%) patients and thrombus formation was noted in 16 patients (28%). A total of 41 patients (72%) exhibited pericatheter sleeve and/or thrombus formation. While 19 of the 32 patients (59%) without previous catheterization had a sleeve around the catheter, only 13 (52%) of 25 patients who had had multiple catheters inserted had a sleeve (P>0.05). Of the eight patients (14%) with BCV stenosis, two had >50% stenosis. Only one patient (2%) had mild stenosis of the SVC. Three patients out of 15 (20%) who had diagnostic venography for the IJV had severe stenosis of the vein. Pericatheter sleeve formation was more frequent in women (P<0.05). However, there were no statistical differences with respect to pericatheter sleeve formation, luminal filling

  12. The importance of effective catheter securement.

    Science.gov (United States)

    Fisher, Jayne

    This article examines the importance of securing/fixing indwelling urinary catheters. The Oxford English dictionary interlinks the two words-'secure' and 'fix'-as having the same meaning. To secure the catheter should not be confused with 'support', whereby the weight of the urine drainage bag is supported with the use of velcro straps or a sleeve. The author introduces the need for the concept of this practice to be at the forefront of nurses' minds in all settings, and this is demonstrated through the use of case studies. Current guidance in this area is reviewed, as well as the problems that can arise when catheters are not secured properly and the available products for health professionals to use. PMID:20948482

  13. Everting (toposcopic) catheter for broad clinical application.

    Science.gov (United States)

    Shook, D R; Doppman, J L; Cattau, E L; Goldstein, S R

    1986-05-01

    The advanced development of the clinical everting (toposcopic) catheter is described. A detailed discussion of the design and outline of the fabrication techniques are followed by a thorough performance evaluation and summary of the first two clinical applications. The everting element is a low-durometer thermoplastic polyurethane elastomer. Surface treatments include the bonding of a hydrophilic polymeric coating, optimized for lubricity, to the sliding internal surfaces of the catheter. Eversion pressures and infusion/aspiration flow rates have been measured under various conditions and the infusate-in-blood mixing potential investigated. A preliminary assessment is given of the clinical performance of the catheter in the vascular delivery of chemotherapy and standard endoscopic retrograde cholangiopancreatography. PMID:3724105

  14. Geographical and climatic limits of needle types of one- and two-needled pinyon pines

    Science.gov (United States)

    Cole, K.L.; Fisher, J.; Arundel, S.T.; Cannella, J.; Swift, S.

    2008-01-01

    Aim: The geographical extent and climatic tolerances of one- and two-needled pinyon pines (Pinus subsect. Cembroides) are the focus of questions in taxonomy, palaeoclimatology and modelling of future distributions. The identification of these pines, traditionally classified by one- versus two-needled fascicles, is complicated by populations with both one- and two-needled fascicles on the same tree, and the description of two more recently described one-needled varieties: the fallax-type and californiarum-type. Because previous studies have suggested correlations between needle anatomy and climate, including anatomical plasticity reflecting annual precipitation, we approached this study at the level of the anatomy of individual pine needles rather than species. Location: Western North America. Methods: We synthesized available and new data from field and herbarium collections of needles to compile maps of their current distributions across western North America. Annual frequencies of needle types were compared with local precipitation histories for some stands. Historical North American climates were modelled on a c. 1-km grid using monthly temperature and precipitation values. A geospatial model (ClimLim), which analyses the effect of climate-modulated physiological and ecosystem processes, was used to rank the importance of seasonal climate variables in limiting the distributions of anatomical needle types. Results: The pinyon needles were classified into four distinct types based upon the number of needles per fascicle, needle thickness and the number of stomatal rows and resin canals. The individual needles fit well into four categories of needle types, whereas some trees exhibit a mixture of two needle types. Trees from central Arizona containing a mixture of Pinus edulis and fallax-type needles increased their percentage of fallax-type needles following dry years. All four needle types occupy broader geographical regions with distinctive precipitation regimes

  15. [Phlebitogenicity of venous catheters of Vialon].

    Science.gov (United States)

    Fassolt, A

    1985-12-01

    During three days 132 surgical patients with postoperative infusion treatment were checked on the frequency of venous reactions in the arms when catheters/cannulas of 4 different materials were used and the outcome compared. A significant result was obtained in connection with the I-cath catheter made of vialon (a polyurethanelike resin polymer) and the L-cath of polyurethane. Phlebitis was decreased to 27.3% resp. 24.2% - approximately half of its usual frequency - when I-cath of polyvinyl-chloride and FEP-teflon vasofix cannulas were applied (both 51.5%). The different predisposing factors of infusion phlebitis are under discussion. PMID:4093198

  16. Catheter ablation of inappropriate sinus tachycardia.

    Science.gov (United States)

    Gianni, Carola; Di Biase, Luigi; Mohanty, Sanghamitra; Gökoğlan, Yalçın; Güneş, Mahmut F; Horton, Rodney; Hranitzky, Patrick M; Burkhardt, J David; Natale, Andrea

    2016-06-01

    Catheter ablation for inappropriate sinus tachycardia (IST) is recommended for patients symptomatic for palpitations and refractory to other treatments. The current approach consists in sinus node modification (SNM), achieved by ablation of the cranial part of the sinus node to eliminate faster sinus rates while trying to preserve chronotropic competence. This approach has a limited efficacy, with a very modest long-term clinical success. To overcome this, proper patient selection is crucial and an epicardial approach should always be considered. This brief review will discuss the current role and limitations of catheter ablation in the management of patients with IST. PMID:26310299

  17. Comparison of catheter tip migration using flexible and stimulating catheters inserted into the adductor canal in a cadaver model.

    Science.gov (United States)

    Webb, Christopher A J; Kim, T Edward; Funck, Natasha; Howard, Steven K; Harrison, T Kyle; Ganaway, Toni; Keng, Heidi; Mariano, Edward R

    2015-06-01

    Use of adductor canal blocks and catheters for perioperative pain management following total knee arthroplasty is becoming increasingly common. However, the optimal equipment, timing of catheter insertion, and catheter dislodgement rate remain unknown. A previous study has suggested, but not proven, that non-tunneled stimulating catheters may be at increased risk for catheter migration and dislodgement after knee manipulation. We designed this follow-up study to directly compare tip migration of two catheter types after knee range of motion exercises. In a male unembalmed human cadaver, 30 catheter insertion trials were randomly assigned to one of two catheter types: flexible or stimulating. All catheters were inserted using an ultrasound-guided short-axis in-plane technique. Intraoperative knee manipulation similar to that performed during surgery was simulated by five sequential range of motion exercises. A blinded regional anesthesiologist performed caliper measurements on the ultrasound images before and after exercise. Changes in catheter tip to nerve distance (p = 0.547) and catheter length within the adductor canal (p = 0.498) were not different between groups. Therefore, catheter type may not affect the risk of catheter tip migration when placed prior to knee arthroplasty. PMID:25510467

  18. Prevention of catheter-related Pseudomonas aeruginosa infection by levofloxacin-impregnated catheters in vitro and in vivo

    Institute of Scientific and Technical Information of China (English)

    Yan Ping; Liu Wei; Kong Jinliang; Wu Hong; Chen Yiqiang

    2014-01-01

    Background Implanted medical catheter-related infections are increasing,hence a need for developing catheter polymers bonded to antimicrobials.We evaluated preventive effects of levofloxacin-impregnated catheters in catheterrelated Psuedomonas aeruginosa (strain PAO1) infection.Methods Drug release from levofloxacin-impregnated catheters was measured in vitro.Levofloxacin-impregnated catheters and polyvinyl chloride (PVC) catheters were immersed in 5 ml 50% Luria Bertani medium containing 108 CFU/ml Pseudomonas aeruginosa then incubated for 6,12,24 or 48 hours at 37℃ when bacteria adhering to the catheters and bacteria in the growth culture medium were determined.Impregnated and PVC catheters were singly implanted subcutaneously in mice,50 μl (107CFU) of PAO1 was injected into catheters.After the first and fifth days challenge,bacterial counts on implanted catheters and in surrounding tissues were determined microbiologically.Bacterial colonization and biofilm formation on implanted catheters were assessed by scanning electron microscopy.Results Drug release from levofloxacin-impregnated catheters was rapid.Levofloxacin-impregnated catheters had significantly fewer bacteria compared to PVC in vitro.After first and fifth day of challenge,no or significantly fewer bacteria adhered to impregnated catheters or in surrounding tissues compared to PVC.Scanning electron microscopical images after first day displayed from none to significantly fewer bacteria adhering to impregnated implanted catheters,compared to bacteria and microcolonies adhering to PVC catheters.After the fifth day,no bacteria were found on impregnated catheters,compared to clusters surrounding mucus-like substance and coral-shaped biofilms with polymorphonuclear leukocyte on PVC catheters.After the first day of challenge,secretion occurred in all implanted catheters with surrounding tissues mildly hyperaemic and swollen.After the fifth day,minute secretions inside impregnated catheters and no

  19. Catheter-Related Sepsis Due to Rhodotorula glutinis

    OpenAIRE

    Hsueh, Po-Ren; Teng, Lee-Jene; Ho, Shen-Wu; Luh, Kwen-Tay

    2003-01-01

    We describe a central venous catheter-related (Port-A-Cath; Smiths Industries Medical Systems [SIMS] Deltec, Inc., St. Paul, Minn.) infection caused by Rhodotorula glutinis in a 51-year-old man with nasopharyngeal carcinoma. He was treated with fluconazole for 8 weeks and had the catheter removed. Two isolates of R. glutinis recovered from blood specimens (one obtained via peripheral veins and one via the catheter) before administration of fluconazole and one recovered from the removed cathet...

  20. Force control of flexible catheter robots for beating heart surgery

    OpenAIRE

    Kesner, Samuel Benjamin; Howe, Robert D.

    2011-01-01

    Recent developments in cardiac catheter technology promise to allow physicians to perform most cardiac interventions without stopping the heart or opening the chest. However, current cardiac devices, including newly developed catheter robots, are unable to accurately track and interact with the fast moving cardiac tissue without applying potentially damaging forces. This paper examines the challenges of implementing force control on a flexible robotic catheter. In particular, catheter frictio...

  1. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ultrasound-guided thyroid biopsy ... Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During a fine needle aspiration ...

  2. 21 CFR 868.5120 - Anesthesia conduction catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction catheter. 868.5120 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5120 Anesthesia conduction catheter. (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to...

  3. Damage of Central Catheters in Home Parenteral Nutrition Patients

    Directory of Open Access Journals (Sweden)

    Błasiak Renata

    2015-11-01

    Full Text Available According to the ESPEN and ASPEN guidelines, in the case of a long-term (>3-month parenteral nutrition should be administered via a subcutaneous central venous catheter (CVC. There are three types of mechanical complications of tunnelled central catheter: catheter rupture, occlusion by TPN depositing and thrombofibrotic occlusion.

  4. Small Bowel Obstruction Due to Suprapubic Catheter Placement

    OpenAIRE

    Bonasso, Patrick C.; Brandon Lucke-Wold; Uzer Khan

    2016-01-01

    Suprapubic catheter placement has associated complications such as bowel injury, bladder injury, or bleeding. This case describes the management of an elderly patient who had suprapubic catheter placement complicated by small bowel obstruction. The catheter had continued production of urine. Further patient treatment required abdominal exploration and bowel resection.

  5. Small Bowel Obstruction Due to Suprapubic Catheter Placement

    Directory of Open Access Journals (Sweden)

    Patrick C. Bonasso

    2016-07-01

    Full Text Available Suprapubic catheter placement has associated complications such as bowel injury, bladder injury, or bleeding. This case describes the management of an elderly patient who had suprapubic catheter placement complicated by small bowel obstruction. The catheter had continued production of urine. Further patient treatment required abdominal exploration and bowel resection.

  6. Small Bowel Obstruction Due to Suprapubic Catheter Placement.

    Science.gov (United States)

    Bonasso, Patrick C; Lucke-Wold, Brandon; Khan, Uzer

    2016-07-01

    Suprapubic catheter placement has associated complications such as bowel injury, bladder injury, or bleeding. This case describes the management of an elderly patient who had suprapubic catheter placement complicated by small bowel obstruction. The catheter had continued production of urine. Further patient treatment required abdominal exploration and bowel resection. PMID:27335801

  7. Activity of sparfloxacin on Staphylococcus epidermidis attached to plastic catheters.

    Science.gov (United States)

    Pascual, A; García, I; Ramirez de Arellano, E; Perea, E J

    1995-08-01

    The activity of sparfloxacin on Staphylococcus epidermidis biofilms on different plastic catheters was evaluated. Sparfloxacin showed high bactericidal activity against S. epidermidis biofilms on Vialon and polyvinylchloride catheters. The combination of sparfloxacin with amikacin or rifampicin significantly increased its activity against bacterial biofilms on polyurethane and Teflon catheters. PMID:8522473

  8. 21 CFR 884.6110 - Assisted reproduction catheters.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Assisted reproduction catheters. 884.6110 Section... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction Devices § 884.6110 Assisted reproduction catheters. (a) Identification. Assisted reproduction catheters are devices used in...

  9. 21 CFR 868.5350 - Nasal oxygen catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril...

  10. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  11. [Textual research on the fire needle and the fire needle therapy].

    Science.gov (United States)

    Liu, T; Zhu, J P; Zhang, Q C

    2016-03-01

    There are different names of the fire needle therapy in the Huang di nei jing (Inner Canon of Huangdi) such as Zu-zhen (), Cui-zhen (,), Fan-zhen (), Huo-cui (), Cui (,,), Cuici ,), Fan zhen jie ci (). It is claimed that the lance needle, the round sharp needle and the long needle recorded in this Classic are puncturing tools for the fire needle therapy. In the Eastern Han Dynasty, Zhang Zhongjing expanded the indications for the fire needle therapy and Huo-zhen () firstly appeared in the Jin kui yu han jing(Classic of the Jade Box and Golden Chamber). The application of the fire needle therapy had been further expanded to a lot of internal and external disorders form the Wei-Jin-Southern and Northern Dynasties to the Ming and Qing Dynasties. There are more detailed records on the manipulation and the tools of the fire needle therapy during this period. In the 1970s, Huo zhen liao fa () was proposed and still in use today. However the Bai-zhen (plain needle) in ancient literature is equal to the filiform needle and should not be regarded as the former name of the fire needle. PMID:27255194

  12. Laser needle guide for the sonic flashlight.

    Science.gov (United States)

    Wang, David; Wu, Bing; Stetten, George

    2005-01-01

    We have extended the real-time tomographic reflection display of the Sonic Flashlight to a laser guidance system that aims to improve safety and accuracy of needle insertion, especially for deep procedures. This guidance system is fundamentally different from others currently available. Two low-intensity lasers are mounted on opposite sides of a needle aimed parallel to the needle. The needle is placed against a notch in the Sonic Flashlight mirror such that the laser beams reflect off the mirror to create bright red spots on the flat panel display. Due to diffuse reflection from these spots, the virtual image created by the flat panel display contains the spots, identifying the projected destination of the needle at its actual location in the tissue. We have implemented our design and validated its performance, identifying several areas for potential improvement. PMID:16685901

  13. Not to Knot a Catheter. Case Report of the Knotting of a Suprapubic Catheter

    Directory of Open Access Journals (Sweden)

    S. A. Farook

    2007-01-01

    Full Text Available A 20-month-old boy, who underwent left nephrectomy, had a suprapubic catheter inserted that knotted within the bladder. This case report identifies possible causes for such occurrences and how best to manage them.

  14. Not to Knot a Catheter. Case Report of the Knotting of a Suprapubic Catheter

    OpenAIRE

    Farook, S. A.; Kariholu, U.; Kousidis, G.; Powlis, M.

    2007-01-01

    A 20-month-old boy, who underwent left nephrectomy, had a suprapubic catheter inserted that knotted within the bladder. This case report identifies possible causes for such occurrences and how best to manage them.

  15. A comparison of the priming properties of two central venous catheters and one pulmonary artery catheter.

    Science.gov (United States)

    Sanderson, P M

    1995-01-01

    The time taken to prime the individual lumina of two multilumen central venous catheters (Viggo-Spectramed 14G 20 cm Hydrocath and Vialon 14G 20 cm Deltacath) and one pulmonary artery catheter (Viggo-Spectramed 110 cm 7.5F Pentacath) at flows between 5 ml.h-1 and 99 ml.h-1 is reported. The catheters supplied by different manufacturers but of identical length and gauge have significantly different priming times (p < 0.001). A protocol which may be used to prime the individual lumina of the three catheters studied is described. By means of an in vitro test the accuracy of this protocol is validated. PMID:7702147

  16. Catheter Removal versus Retention in the Management of Catheter-Associated Enterococcal Bloodstream Infections

    Directory of Open Access Journals (Sweden)

    Jonas Marschall

    2013-01-01

    Full Text Available BACKGROUND: Enterococci are an important cause of central venous catheter (CVC-associated bloodstream infections (CA-BSI. It is unclear whether CVC removal is necessary to successfully manage enterococcal CA-BSI.

  17. The risks and benefits of suprapubic catheters.

    Science.gov (United States)

    Yates, Ann

    Suprapubic catheterisation can improve some patients' quality of life but the insertion procedure, as well as changing and managing the catheter, carry risks of infection and other negative patient outcomes. This article highlights the advantages and disadvantages, indications and contraindications, and the potential benefits, so health professionals can understand the relevant issues and assess and inform patients accordingly. PMID:27017651

  18. Complications after placement of peritoneal catheter

    Directory of Open Access Journals (Sweden)

    Đurđević-Mirković Tatjana

    2011-01-01

    Full Text Available Introduction. Peritoneal dialysis is one of the modalities used for treatment of end-stage chronic kidney failure. Nowadays, this method is complementary to haemodialysis and renal transplantation. Owing to the rich vascularization of the peritoneum, it is used in the processes of osmosis and diffusion, enabling the removal of uremic material from the body. The procedure includes introduction of peritoneal fluid via the peritoneal catheter. Complications. The catheter is placed through the anterior abdominal wall with its tip positioned in the small pelvis. There are several techniques for catheter placement considered minimally invasive, which, however, may be associated with various complications. These complications can be divided into mechanical (catheter dysfunction, cuff protrusion, hernia, dialysate leaks, visceral perforation and infectious (early peritonitis, exit site or tunnel infection, surgical wounds. In most cases, such complications are rare and can be successfully managed using conservative therapy; however, in some situations severe complications can endanger the life of the patient. On-time recognition of complications, particularly in patients at risk, is of paramount importance for an effective treatment. The development of complications can increase the morbidity and the chance of treatment failure, and therefore transfer to haemodialysis. Conclusion. The preoperative evaluation and determination of the risk factors as well as the early recognition and adequate management of complications are essential in their prevention.

  19. Percutaneous Transhepatic Biliary Drainage Using a Ligated Catheter for Recurrent Catheter Obstruction: Antireflux Technique

    OpenAIRE

    Hamada, Tsuyoshi; Tsujino, Takeshi; Isayama, Hiroyuki; Hakuta, Ryunosuke; ITO Yukiko; Nakata, Ryo; Koike, Kazuhiko

    2013-01-01

    Percutaneous transhepatic biliary drainage (PTBD) is an established procedure for biliary obstruction. However, duodenobiliary or jejunobiliary reflux of the intestinal contents through a PTBD catheter sometimes causes recurrent catheter obstruction or cholangitis. A 64-year-old female patient with a history of choledochojejunostomy was referred to our department with acute cholangitis due to choledochojejunal anastomotic obstruction. Emergent PTBD was performed, but frequent obstructions of ...

  20. Collimation with hollow electron beams

    CERN Document Server

    Stancari, G; Annala, G; Kuznetsov, G; Shiltsev, V; Still, D A; Vorobiev, L G

    2011-01-01

    A novel concept of controlled halo removal for intense high-energy beams in storage rings and colliders is presented. It is based on the interaction of the circulating beam with a 5-keV, magnetically confined, pulsed hollow electron beam in a 2-m-long section of the ring. The electrons enclose the circulating beam, kicking halo particles transversely and leaving the beam core unperturbed. By acting as a tunable diffusion enhancer and not as a hard aperture limitation, the hollow electron beam collimator extends conventional collimation systems beyond the intensity limits imposed by tolerable losses. The concept was tested experimentally at the Fermilab Tevatron proton-antiproton collider. The first results on the collimation of 980-GeV antiprotons are presented.

  1. The establishment of implanted VX2 liver tumor model in rabbits and discussion on superselective left hepatic arterial catheterization with micro-catheter technique via femoral artery

    International Nuclear Information System (INIS)

    Objective: To establish the implanted VX2 liver tumor model in rabbits and to discuss the feasibility and technical features of superselective left hepatic arterial catheterization by using micro-catheter through the femoral artery catheter sheath. Methods: Forty New Zealand white rabbits were inoculated with fragments of VX2 tumor into the medial left lobe of liver by using a 16G lumbar puncture needle through laparotomy route. Two weeks later, all the rabbits were proved to be successfully inoculated with liver neoplasm on CT scanning. Then, the catheter sheath was inserted into one of the femoral arteries, which was followed by celiac artery angiography and left hepatic artery catheterization with a micro-catheter under DSA guidance in order to evaluate the main branches of celiac artery and the imaging manifestations of VX2 liver tumor. After that, some scheduled interventional experiments were carried out. Results: Imaging examination and histopathologic study showed that the successful rate of implanted rabbit VX2 liver tumor was 100% (40/40). And the successful rate of the catheter sheath inserted to femoral artery was 97.5% (39/40). The successful rate of celiac artery, gastro-hepatic artery, common hepatic artery, proper hepatic artery and left hepatic artery catheterizations was 100% (39/39), 100% (39/39), 100% (39/39), 94.9% (37/39) and 71.2% (28/39) respectively. Conclusion: To implant tumor tissue mass through laparotomy is a stable and reliable method to establish rabbit VX2 liver tumor model. The insertion of micro-catheter through rabbit femoral catheter sheath approach is a convenient and simple technique to be carried out for the left hepatic artery catheterization and it can efficiently solve the technical difficulties when performing the interventional treatment of the rabbit VX2 hepatic tumor via left hepatic artery approach. (authors)

  2. Micro-hollow cathode dischargers

    International Nuclear Information System (INIS)

    In order to develop a hollow cathode discharge (HCD) with its increased current over planar electrode glow discharges, the cathode fall, which is on the order of the mean free path for ionization, must be comparable in length to the hole diameter. This indicates that the discharge parameters vary with pressure, p, times hole diameter, D. The pD product for stable operation of a hollow cathosde discharge was quoted to be on the order of one to ten Torr cm for noble gases, less for molecular gases. White (1959) observed the hollow cathode effect in a neon discharge at a pressure of 100 Torr when the hole dimensions were less than 1 mm. The cathode hole in his experiments changed from a cylindrical into a spherical cavity due to sputtering. The anode consisted in White's experiment of a pin on the axis of the discharge geometry. We have studied micro-hollow (submillimeter) cathode discharges between two electrodes with aligned cylindrical holes by determining the current-voltage characteristics and the visual appearance of the discharge in argon over a wide range of pressure and voltage. The cross-section of the discharge geometry. The cathode is made of molybdenum or barium oxide inserted into a tungsten matrix (dispenser-cathode), the anode of molybdenum, and the dielectric spacer is mica. The discharge was operated under dc conditions, with half-wave rectified ac voltage applied, and pulsed with a 400 μs rectangular voltage pulse. The lower limit in pressure was determined by the maximum voltage which could be applied to the discharge geometry without breakdown along insulators. The upper limit, in this study, is determined by the transition from cathode electrode emission due to ion-impact to thermal emission of electrons, which causes a dramatic increase in current and a drop in forward voltage to values on the order of 20 V

  3. Hollow Spheres in Composite Materials and Metallic Hollow Sphere Composites (MHSC)

    Science.gov (United States)

    Baumeister, Erika; Molitor, Martin

    The newly developed metallic hollow spheres are used in combination with a polymeric matrix for producing metallic hollow-sphere-composites (MSHC), which have been developed for mechanical engineering applications in the “InnoZellMet” project.

  4. Cascade decays of hollow ions

    International Nuclear Information System (INIS)

    A multiple-electron-emission process for atoms with one or more inner-shell vacancies is treated using the radiative- and Auger-electron-emission cascade model, in which inner-shell holes are assumed to decay by sequentially emitting radiations and/or Auger electrons. Such hollow ions are produced by synchrotron irradiation of atomic targets and in ion-surface interactions with multiple-electron transfers. The final charge-state distribution is determined by the Auger and radiative branching ratios at each stage of the decay sequence. At intermediate stages of cascade, hollow ions with more than one hole in different ionization stages are created. The Ne, Mg, and Fe14+ ions with the initial 1s, 2s, and 2p vacancies are considered in detail, and the core charge dependence of the maximum charge state is studied. The hollow Mg ion with double initial 1s holes is analyzed, and the result compared with that for the case of one 1s hole. The peak is shifted more than two units to a higher degree of ionization. The correlated shake-off and shake-up multiple-electron processes are not considered, but they are expected to cause further shifts

  5. Purification of nanoparticles by hollow fiber diafiltration

    International Nuclear Information System (INIS)

    Hollow Fiber Diafiltration (Hollow Fiber Tangential Flow Filtration) is an efficient and rapid alternative to traditional methods of nanoparticle purification such as ultracentrifugation, stirred cell filtration, dialysis or chromatography. Hollow Fiber Diafiltration can be used to purify a wide range of nanoparticles including liposomes, colloids, magnetic particles and nanotubes. Hollow Fiber Diafiltration is a membrane based method where pore size determines the retention or transmission of solution components. It is a flow process where the sample is gently circulated through a tubular membrane. With controlled replacement of the permeate or (dialysate), pure nanoparticles can be attained. Hollow Fiber Diafiltration can be directly scaled up from R and D volumes to production. By adding more membrane fibers and maintaining the operating parameters, large volumes can be processed in the same time with the same pressure, and flow dynamics as bench-scale volumes. Keywords: hollow fiber, Diafiltration, filtration, purification, tangential flow filtration.

  6. Purification of nanoparticles by hollow fiber diafiltration

    Science.gov (United States)

    Veeken, J.

    2012-09-01

    Hollow Fiber Diafiltration (Hollow Fiber Tangential Flow Filtration) is an efficient and rapid alternative to traditional methods of nanoparticle purification such as ultracentrifugation, stirred cell filtration, dialysis or chromatography. Hollow Fiber Diafiltration can be used to purify a wide range of nanoparticles including liposomes, colloids, magnetic particles and nanotubes. Hollow Fiber Diafiltration is a membrane based method where pore size determines the retention or transmission of solution components. It is a flow process where the sample is gently circulated through a tubular membrane. With controlled replacement of the permeate or (dialysate), pure nanoparticles can be attained. Hollow Fiber Diafiltration can be directly scaled up from R&D volumes to production. By adding more membrane fibers and maintaining the operating parameters, large volumes can be processed in the same time with the same pressure, and flow dynamics as bench-scale volumes. Keywords: hollow fiber, Diafiltration, filtration, purification, tangential flow filtration.

  7. Synthesis and Characterization of Hollow and Non-Hollow Monodisperse Colloidal TiO2 Particles

    OpenAIRE

    Eiden-Assmann, Stefanie; Widoniak, Johanna; Maret, Georg

    2005-01-01

    Monodisperse spherical hollow and non-hollow titania particles of variable sizes are produced in a sol–gel synthesis from Ti(EtO)4 in ethanol. Hollow spherical particles of rutile were obtained by coating colloidal polystyrene beads with a titanium oxide hydrate layer and subsequently calcination at elevated temperatures in oxygen atmosphere. The non-hollow titania particles were produced in the presence of salt or polymer solution. The influence of different salt ions or polymer molecules on...

  8. Apical pressures developed by needles for canal irrigation.

    Science.gov (United States)

    Bradford, C E; Eleazer, P D; Downs, K E; Scheetz, J P

    2002-04-01

    Drying instrumented canals with pressurized air may result in patient morbidity or even fatality. Low pressure and side vent needles have been suggested to lessen the danger. This study observed apical pressures from different needles inserted deeply into small round and ovoid canals as instrumentation progressed. Low-pressure (5 psi) air was injected through the needles, and apical pressures were recorded after each instrument. Pressures varied greatly within each test group. Generalities that can be drawn are that binding the needle within the canal gives higher pressures than with the needle slightly short of binding and that pressures were higher with apexes instrumented to size 30 and higher. With the needle tightly bound, neither needle size, needle design, nor canal shape resulted in statistically significant mean pressure differences. With the needle slightly withdrawn, larger bore needles gave higher pressures than small diameter needles. Caution is advised with the clinical use of pressurized air in the drying of root canals. PMID:12043877

  9. Effect of needle tract bleeding on occurrence of pneumothorax after transthoracic needle biopsy

    International Nuclear Information System (INIS)

    Purpose: Occasionally bleeding along the needle trajectory is observed at post-biopsy computed tomographic sections. This study was designed to evaluate the possible effect of needle tract bleeding on the occurrence of pneumothorax and on requirement of chest tube insertion. Materials and methods: Two hundred eighty-four needle biopsies performed in 275 patients in whom the needle traversed the aerated lung parenchyma were retrospectively reviewed. Bleeding along the needle tract, occurrence of pneumothorax and need for chest tube insertion, type and size of the needle, size of the lesion, length of the lung traversed by the needle, presence or absence of emphysema were noted. Effect of these factors on the rate of pneumothorax and needle-tract bleeding was evaluated. The data were analyzed by χ2 test. Results: Pneumothorax developed in 100 (35%) out of 284 procedures requiring chest tube placement in 16 (16%). Variables that were significantly associated with an increased risk of pneumothorax were depth of the lesion (P 0.05). However, analysis of the relation between length of lung traversed by the needle, tract-bleeding and pneumothorax rate indicated that tract-bleeding had a preventive effect on development of pneumothorax (P 0.05). Conclusion: Bleeding in the needle tract has a preventive effect on the occurrence of the pneumothorax in deep-seated lesions and in the presence of emphysema, although it does not affect the overall rate of pneumothorax

  10. Radiologically placed tunneled peritoneal catheter in palliation of malignant ascites

    International Nuclear Information System (INIS)

    The purpose of this study was to evaluate retrospectively the safety and effectiveness of radiologically placed tunneled peritoneal catheter in palliation of malignant ascites. Between July 2005 and June 2009, 41 tunneled peritoneal catheters were placed under ultrasonographic and fluoroscopic guidance in 40 patients (mean age, 55 years; 22 women) who had symptomatic malignant ascites. No procedure related mortality was observed. Major complication occurred in one patient (2.5%) in the form of serious bacterial peritonitis that necessitated catheter removal. Minor complications such as minor bacterial peritonitis, catheter dislodgement, tunnel infection, and catheter blockage occurred in 11 patients (27.5%). The mean duration of survival after catheter placement was 11.8 weeks. All patients expired of their primary malignancies in the follow-up. Radiologically placed tunneled peritoneal catheter is safe and effective in palliation of symptomatic malignant ascites.

  11. WE-A-17A-10: Fast, Automatic and Accurate Catheter Reconstruction in HDR Brachytherapy Using An Electromagnetic 3D Tracking System

    Energy Technology Data Exchange (ETDEWEB)

    Poulin, E; Racine, E; Beaulieu, L [CHU de Quebec - Universite Laval, Quebec, Quebec (Canada); Binnekamp, D [Integrated Clinical Solutions and Marketing, Philips Healthcare, Best, DA (Netherlands)

    2014-06-15

    Purpose: In high dose rate brachytherapy (HDR-B), actual catheter reconstruction protocols are slow and errors prompt. The purpose of this study was to evaluate the accuracy and robustness of an electromagnetic (EM) tracking system for improved catheter reconstruction in HDR-B protocols. Methods: For this proof-of-principle, a total of 10 catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a Philips-design 18G biopsy needle (used as an EM stylet) and the second generation Aurora Planar Field Generator from Northern Digital Inc. The Aurora EM system exploits alternating current technology and generates 3D points at 40 Hz. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical CT system with a resolution of 0.089 mm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, 5 catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 seconds or less. This would imply that for a typical clinical implant of 17 catheters, the total reconstruction time would be less than 3 minutes. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.92 ± 0.37 mm and 1.74 ± 1.39 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be significantly more accurate (unpaired t-test, p < 0.05). A mean difference of less than 0.5 mm was found between successive EM reconstructions. Conclusion: The EM reconstruction was found to be faster, more accurate and more robust than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators. We would like to disclose that the equipments, used in this study, is coming from a collaboration with Philips Medical.

  12. Optical and electrical characteristics of hollow needle to plate atmospheric pressure discharge in nitrogen

    Czech Academy of Sciences Publication Activity Database

    Šimek, Milan; Schmidt, Jiří; Pekárek, S.; Khun, J.

    2006-01-01

    Roč. 51, č. 5 (2006), s. 27. ISSN 0003-0503. [Annual Gaseous Electronic Conference/59nd./. Columbus,Ohio, USA, 10.10.2006-13.10.2006] R&D Projects: GA AV ČR(CZ) IAA1043403 Institutional research plan: CEZ:AV0Z20430508 Keywords : positive corona discharge * streamer * mean repetition frequency * mean propagation velocity Subject RIV: BL - Plasma and Gas Discharge Physics

  13. Optical diagnostics of the hollow needle to plate electrical discharge in air at atmospheric pressure

    Czech Academy of Sciences Publication Activity Database

    Pekárek, S.; Šimek, Milan

    2004-01-01

    Roč. 54, suppl. C (2004), C728-C734. ISSN 0011-4626. [Symposium on Plasma Physics and Technology /21./. Praha, 14.06.2004-17.06.2004] R&D Projects: GA AV ČR IAA1043403 Institutional research plan: CEZ:AV0Z2043910 Keywords : optical diagnostics, electrical discharge, ozone generation Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.292, year: 2004

  14. Fine-needle aspiration by vacuum tubes.

    Science.gov (United States)

    Holmquist, N D

    1989-07-01

    Fine-needle aspiration of subcutaneous masses, accepted in many parts of Europe and the Americas as a routine diagnostic technique, employs a syringe holder to facilitate the creation of a vacuum to withdraw cells. This investigation demonstrates that a vacuum tube used in venipuncture can be used to supply the negative pressure to suck cells into the needle. This apparatus is more readily available than a syringe holder in hospitals and clinics, and particularly provides the operator with a more dexterous approach to the mass because the fingers holding the needle can be much closer to the mass being immobilized by the other hand. PMID:2750713

  15. Non-contact ultrasonic inspection of medical catheters for polymeric bond defects

    Energy Technology Data Exchange (ETDEWEB)

    Xu Peng; Yu Yi; Chan, Andrew K.; Harms, Kent D.; Suh, C. Steve

    2004-10-15

    A non-contact, laser-optic based laser ultrasonic technique referred to as the thermo-acousto-photonic non-destructive evaluation (TAP-NDE) was employed to investigate bond integrity and localized stiffening due to an attached wire stent on small diameter polymeric catheters. Laser-generated interrogating ultrasonic dispersive waves in the catheter were acquired using a fiber-tip interferometer (FTI) running on a HeNe laser. The basic notions of zero-crossing rate and artificial neural network (ANN) were applied to digitized tubular guided-waves to uniquely identify each of the following three bond defects: tensile pull, needle puncture, and crease. These induced flaws represent possible manufacturing defects such as de-bond, potential leak sources, and geometry irregularities. Zero-crossing rates were also found to uniquely identify localized stiffening due to an attached wire stent proving that this technique can unambiguously identify propagation modes from among non-propagation modes or vibrations. The 100% success rate reported in the paper renders the utility of TAP-NDE, along with ANN based classification scheme using zero-crossing rates, a viable quantitative measure for inspecting small-diameter polymeric medical tubing for sub-mm defects in real-time.

  16. Non-contact ultrasonic inspection of medical catheters for polymeric bond defects

    International Nuclear Information System (INIS)

    A non-contact, laser-optic based laser ultrasonic technique referred to as the thermo-acousto-photonic non-destructive evaluation (TAP-NDE) was employed to investigate bond integrity and localized stiffening due to an attached wire stent on small diameter polymeric catheters. Laser-generated interrogating ultrasonic dispersive waves in the catheter were acquired using a fiber-tip interferometer (FTI) running on a HeNe laser. The basic notions of zero-crossing rate and artificial neural network (ANN) were applied to digitized tubular guided-waves to uniquely identify each of the following three bond defects: tensile pull, needle puncture, and crease. These induced flaws represent possible manufacturing defects such as de-bond, potential leak sources, and geometry irregularities. Zero-crossing rates were also found to uniquely identify localized stiffening due to an attached wire stent proving that this technique can unambiguously identify propagation modes from among non-propagation modes or vibrations. The 100% success rate reported in the paper renders the utility of TAP-NDE, along with ANN based classification scheme using zero-crossing rates, a viable quantitative measure for inspecting small-diameter polymeric medical tubing for sub-mm defects in real-time

  17. Encapsulation of dye molecules and nanoparticles in hollow organogel fibers of a nonchiral polyurethane model compound.

    Science.gov (United States)

    Khan, Mostofa Kamal; Sundararajan, Pudupadi

    2011-01-24

    We present the case of a nonchiral organogelator that forms hollow fibers and encapsulates silver nanoparticles (SNP) and a dye molecule. The biscarbamate molecule (a model compound for polyurethanes), which has two hydrogen-bonding motifs symmetrically attached to n-dodecyl side chains (C(12)), gels benzonitrile with hollow fibrillar morphology. The C(12) molecules form sheets that eventually wrap into hollow fibers to form the gel network. Herein, two-component gels were prepared with C(12) as one component and SNP, phthalocyanine (Pc), or perylene (Pe) as the other. Microscopic analysis and partial melting experiments confirmed the inclusion of the silver nanoparticles and phthalocyanine into the hollow fibers. On the other hand, Pe molecules tend to form crystals at the outer surface of the C(12) fibers, which results in a significant increase in the width of the gel fibers. This difference in the behavior of Pc and Pe molecules were accounted for by their crystal geometry and significantly different crystal growth rate compared with that of C(12) fiber formation in the gels. Pc crystallizes in a needle shape that facilitates occlusion in the gel fibers, whereas Pe forms large platelets. X-ray diffraction and spectroscopic analysis of the two-component gels along with their neat components confirmed that there was no change in the packing behavior of the Pc and Pe molecules in the gels. Therefore, these are examples of two-component physical gels in which the Pc crystals are occluded within the hollow fibers of C(12) by physical mixing of the components without the aid of any inter-molecular interactions between the different components. We have thus shown that lumen-loaded gel fibers with nanoparticles and dye molecules can be prepared by the two-component gel route, provided that the above growth rate, shape, and size conditions are satisfied. PMID:21243684

  18. Distribution of elements in needles of Pinus massoniana (Lamb.) was uneven and affected by needle age

    International Nuclear Information System (INIS)

    Macronutrients (P, S, K, Na, Mg, Ca), heavy metals (Fe, Zn, Mn, Cu, Pb, Cr, Ni, Cd) and Al concentrations as well as values of Ca/Al in the tip, middle, base sections and sheaths of current year and previous year needles of Pinus massoniana from Xiqiao Mountain were analyzed and the distribution patterns of those elements were compared. The results indicated that many elements were unevenly distributed among the different components of needles. Possible deficiency of P, K, Ca, Mn and Al toxicity occurred in needles under air pollution. Heavy metals may threaten the health of Masson pine. Needle sheaths were good places to look for particulate pollutants, in this case including Fe, Cu, Zn, Pb, Cr, Cd and Al. - Pine needle sections as bioindicator for heavy metals and nutrient deficiency particularly needle sheath for particle pollutants

  19. Distribution of elements in needles of Pinus massoniana (Lamb.) was uneven and affected by needle age

    International Nuclear Information System (INIS)

    Macronutrients (P, S, K, Na, Mg, Ca), heavy metals (Fe, Zn, Mn, Cu, Pb, Cr, Ni, Cd,) and Al concentrations as well as values of Ca/Al in the tip, middle and base sections, and sheaths of current year and previous year needles of Pinus massoniana from Xiqiao Mountain were analyzed and the distribution patterns of those elements were compared. The results indicated that many elements were unevenly distributed among the different components of needles. Possible deficiency of P, K, Ca, Mn and Al toxicity occurred in needles under air pollution. Heavy metals may threaten the health of Masson pine. Needle sheaths were good places to look for particulate pollutants, in this case including Fe, Cu, Zn, Pb, Cr, Cd and Al. - Pine needle sections as bioindicator for heavy metals and nutrient deficiency particularly needle sheath for particle pollutants

  20. Evaluation of the friction coefficient, the radial stress, and the damage work during needle insertions into agarose gels.

    Science.gov (United States)

    Urrea, Fabián A; Casanova, Fernando; Orozco, Gustavo A; García, José J

    2016-03-01

    Agarose hydrogels have been extensively used as a phantom material to mimic the mechanical behavior of soft biological tissues, e.g. in studies aimed to analyze needle insertions into the organs producing tissue damage. To better predict the radial stress and damage during needle insertions, this study was aimed to determine the friction coefficient between the material of commercial catheters and hydrogels. The friction coefficient, the tissue damage and the radial stress were evaluated at 0.2, 1.8, and 10mm/s velocities for 28, 30, and 32 gauge needles of outer diameters equal to 0.36, 0.31, and 0.23mm, respectively. Force measurements during needle insertions and retractions on agarose gel samples were used to analyze damage and radial stress. The static friction coefficient (0.295±0.056) was significantly higher than the dynamic (0.255±0.086). The static and dynamic friction coefficients were significantly smaller for the 0.2mm/s velocity compared to those for the other two velocities, and there was no significant difference between the friction coefficients for 1.8 and 10mm/s. Radial stress averages were 131.2±54.1, 248.3±64.2, and 804.9±164.3Pa for the insertion velocity of 0.2, 1.8, and 10mm/s, respectively. The radial stress presented a tendency to increase at higher insertion velocities and needle size, which is consistent with other studies. However, the damage work did not show to be a good predictor of tissue damage, which appears to be due to simplifications in the analytical model. Differently to other approaches, the method proposed here based on radial stress may be extended in future studies to quantity tissue damage in vivo along the entire needle track. PMID:26700572

  1. Pine needle abortion biomarker detected in bovine fetal fluids

    Science.gov (United States)

    Pine needle abortion is a naturally occurring condition in free-range cattle caused by the consumption of pine needles from select species of cypress, juniper, pine, and spruce trees. Confirmatory diagnosis of pine needle abortion has previously relied on a combined case history of pine needle cons...

  2. Distributed pressure sensors for a urethral catheter.

    Science.gov (United States)

    Ahmadi, Mahdi; Rajamani, Rajesh; Timm, Gerald; Sezen, A S

    2015-08-01

    A flexible strip that incorporates multiple pressure sensors and is capable of being fixed to a urethral catheter is developed. The urethral catheter thus instrumented will be useful for measurement of pressure in a human urethra during urodynamic testing in a clinic. This would help diagnose the causes of urinary incontinence in patients. Capacitive pressure sensors are fabricated on a flexible polyimide-copper substrate using surface micromachining processes and alignment/assembly of the top and bottom portions of the sensor strip. The developed sensor strip is experimentally evaluated in an in vitro test rig using a pressure chamber. The sensor strip is shown to have adequate sensitivity and repeatability. While the calibration factors for the sensors on the strip vary from one sensor to another, even the least sensitive sensor has a resolution better than 0.1 psi. PMID:26738054

  3. Pancreas tumor interstitial pressure catheter measurement

    Science.gov (United States)

    Nieskoski, Michael D.; Gunn, Jason; Marra, Kayla; Trembly, B. Stuart; Pogue, Brian W.

    2016-03-01

    This paper highlights the methodology in measuring interstitial pressure in pancreatic adenocarcinoma tumors. A Millar Mikrotip pressure catheter (SPR-671) was used in this study and a system was built to amplify and filter the output signal for data collection. The Millar pressure catheter was calibrated prior to each experiment in a water column at 37°C, range of 0 to 60 inH2O (112 mmHg), resulting in a calibration factor of 33 mV / 1 inH2O. The interstitial pressures measured in two orthotopically grown pancreatic adenocarcinoma tumor were 57 mmHg and 48 mmHg, respectively. Verteporfin uptake into the pancreatic adenocarcinoma tumor was measured using a probe-based experimental dosimeter.

  4. Retrograde Epidural Catheter Relieves Intractable Sacral Pain.

    Science.gov (United States)

    Gupta, Ruchir; Shodhan, Shivam; Hosny, Amr

    2016-01-01

    Pain caused by tumor infiltration of the sacral area remains a major clinical challenge. Patients with poor pain control despite comprehensive medical management may be treated with neuraxial techniques such as continuous epidural or spinal anesthetic. We report a case in which a patient with metastatic breast cancer experienced inadequate pain relief after multiple intravenous pain management regimens as well as intrathecal (IT) drug delivery. The concentration of local anesthetics delivered via the IT catheter was limited due to the patient's baseline motor weakness which would be exacerbated with higher concentrations of local anesthetics. Thus, a decision was made to insert an epidural catheter via a retrograde technique to provide the patient with a "band of anesthesia" which would provide profound sensory blockade without concomitant motor weakness. Pain refractory to other modalities of pain control was successfully treated with the epidural technique. PMID:27162431

  5. Percutaneous Placement of Central Venous Catheters: Comparing the Anatomical Landmark Method with the Radiologically Guided Technique for Central Venous Catheterization Through the Internal Jugular Vein in Emergent Hemodialysis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Koroglu, M.; Demir, M.; Koroglu, B.K.; Sezer, M.T.; Akhan, O.; Yildiz, H.; Yavuz, L.; Baykal, B.; Oyar, O. [Suleyman Demirel Univ., Isparta (Turkey). Depts. of Radiology, Internal Medicine and Anesthesiology

    2006-02-15

    Purpose: To compare the success and immediate complication rates of the anatomical landmark method (group 1) and the radiologically (combined real-time ultrasound and fluoroscopy) guided technique (group 2) in the placement of central venous catheters in emergent hemodialysis patients. Material and Methods: The study was performed prospectively in a randomized manner. The success and immediate complication rates of radiologically guided placement of central venous access catheters through the internal jugular vein (n = 40) were compared with those of the anatomical landmark method (n 40). The success of placement, the complications, the number of passes required, and whether a single or double-wall puncture occurred were also noted and compared. Results: The groups were comparable in age and sex. The indication for catheter placement was hemodialysis access in all patients. Catheter placement was successful in all patients in group 2 and unsuccessful in 1 (2.5%) patient in group 1. All catheters functioned adequately and immediately after the placement (0% initial failure rate) in group 2, but 3 catheters (7.5% initial failure rate) were non-functional just after placement in group 1. The total number of needle passes, double venous wall puncture, and complication rate were significantly lower in group 2. Conclusion: Percutaneous central venous catheterization via the internal jugular vein can be performed by interventional radiologists with better technical success rates and lower immediate complications. In conclusion, central venous catheterization for emergent dialysis should be performed under both real-time ultrasound and fluoroscopic guidance.

  6. Electromagnetic tracking and steering for catheter navigation

    OpenAIRE

    O'Donoghue, Kilian

    2014-01-01

    This thesis explores the use of electromagnetics for both steering and tracking of medical instruments in minimally invasive surgeries. The end application is virtual navigation of the lung for biopsy of early stage cancer nodules. Navigation to the peripheral regions of the lung is difficult due to physical dimensions of the bronchi and current methods have low successes rates for accurate diagnosis. Firstly, the potential use of DC magnetic fields for the actuation of catheter devices with ...

  7. Robotic Catheters for Beating Heart Surgery

    OpenAIRE

    Kesner, Samuel Benjamin

    2011-01-01

    Compliant and flexible cardiac catheters provide direct access to the inside of the heart via the vascular system without requiring clinicians to stop the heart or open the chest. However, the fast motion of the intracardiac structures makes it difficult to modify and repair the cardiac tissue in a controlled and safe manner. In addition, rigid robotic tools for beating heart surgery require the chest to be opened and the heart exposed, making the procedures highly invasive. The novel robot...

  8. Transpleural central venous catheter discovered during thoracotomy

    OpenAIRE

    Ashima Malhotra; Prakash Sharma; Ashvini Kumar; Nikhil Malhotra

    2014-01-01

    We report an uncommon complication of subclavian central venous catheterization, discovered at thoracotomy. The central venous catheter (CVC) was placed by left infraclavicular route after induction of general anesthesia. CVC was secured after aspiration of blood and satisfactory central venous tracing. On thoracotomy, CVC was noticed to traverse the pleural cavity while the tracing was normal. CVC was thus removed consequent to which bleeding from each puncture site was noticed, that were se...

  9. Sliding Mode Control of Steerable Needles.

    Science.gov (United States)

    Rucker, D Caleb; Das, Jadav; Gilbert, Hunter B; Swaney, Philip J; Miga, Michael I; Sarkar, Nilanjan; Webster, Robert J

    2013-10-01

    Steerable needles can potentially increase the accuracy of needle-based diagnosis and therapy delivery, provided they can be adequately controlled based on medical image information. We propose a novel sliding mode control law that can be used to deliver the tip of a flexible asymmetric-tipped needle to a desired point, or to track a desired trajectory within tissue. The proposed control strategy requires no a priori knowledge of model parameters, has bounded input speeds, and requires little computational resources. We show that if the standard nonholonomic model for tip-steered needles holds, then the control law will converge to desired targets in a reachable workspace, within a tolerance that can be defined by the control parameters. Experimental results validate the control law for target points and trajectory following in phantom tissue and ex vivo liver. Experiments with targets that move during insertion illustrate robustness to disturbances caused by tissue deformation. PMID:25400527

  10. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2010-08-15

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate.

  11. Biological safety evaluation of the modified urinary catheter

    Energy Technology Data Exchange (ETDEWEB)

    Kowalczuk, Dorota, E-mail: dorota.kowalczuk@umlub.pl [Department of Medicinal Chemistry, Medical University of Lublin, Jaczewskiego 4, 20-090 Lublin (Poland); Przekora, Agata; Ginalska, Grazyna [Department of Biochemistry and Biotechnology, Medical University of Lublin, Chodzki 1, 20-093 Lublin (Poland)

    2015-04-01

    The purpose of this study was to evaluate in vitro safety of the novel tosufloxacin (TOS)-treated catheters with the prolonged antimicrobial activity. The test samples of silicone latex catheter were prepared by the immobilization of TOS on chitosan (CHIT)-coated catheter by means of covalent bonds and non-covalent interactions. Each step of the modification process of catheter surface was observed using ATR–Fourier transform infrared spectroscopy. In vitro cytotoxicity of the modified and unmodified catheters was assessed by direct and indirect tests in accordance with ISO standards using green monkey kidney (GMK) cell line. The MTT, lactate dehydrogenase activity (LDH), WST-8, Sulforhodamine B (SRB) test results and microscopic observation clearly indicated that unmodified silicone latex catheters decrease cell metabolic activity, act as a cytotoxic agent causing cell lysis and induce cell death through necrotic or apoptotic process. We suggest that chitosan coat with TOS immobilized limits leaching of harmful agents from silicone latex material, which significantly enhances survivability of GMK cells and therefore is quite a good protection against the cytotoxic effect of this material. - Highlights: • Characterization of the novel antimicrobial urinary catheters • Monitoring of the catheter modification by FTIR analysis • Confirmation of high cytotoxicity of latex-based catheter used in urological practice • Chitosan-coated and tosufloxacin-treated catheter is less toxic than the untreated one. • The proposed surface modification protects cells against latex-induced death.

  12. Biological safety evaluation of the modified urinary catheter

    International Nuclear Information System (INIS)

    The purpose of this study was to evaluate in vitro safety of the novel tosufloxacin (TOS)-treated catheters with the prolonged antimicrobial activity. The test samples of silicone latex catheter were prepared by the immobilization of TOS on chitosan (CHIT)-coated catheter by means of covalent bonds and non-covalent interactions. Each step of the modification process of catheter surface was observed using ATR–Fourier transform infrared spectroscopy. In vitro cytotoxicity of the modified and unmodified catheters was assessed by direct and indirect tests in accordance with ISO standards using green monkey kidney (GMK) cell line. The MTT, lactate dehydrogenase activity (LDH), WST-8, Sulforhodamine B (SRB) test results and microscopic observation clearly indicated that unmodified silicone latex catheters decrease cell metabolic activity, act as a cytotoxic agent causing cell lysis and induce cell death through necrotic or apoptotic process. We suggest that chitosan coat with TOS immobilized limits leaching of harmful agents from silicone latex material, which significantly enhances survivability of GMK cells and therefore is quite a good protection against the cytotoxic effect of this material. - Highlights: • Characterization of the novel antimicrobial urinary catheters • Monitoring of the catheter modification by FTIR analysis • Confirmation of high cytotoxicity of latex-based catheter used in urological practice • Chitosan-coated and tosufloxacin-treated catheter is less toxic than the untreated one. • The proposed surface modification protects cells against latex-induced death

  13. Indwelling intrathecal catheter with subcutaneous abdominal reservoir: a viable baclofen delivery system in severely cachectic patients.

    Science.gov (United States)

    Waqar, Mueez; Ellenbogen, Jonathan R; Kumar, Ram; Sneade, Christine; Zebian, Bassel; Williams, Dawn; Pettorini, Benedetta L

    2014-10-01

    Intrathecal baclofen (ITB) is a reversible treatment that reduces muscle tone to ameliorate spasticity and dystonia in patients with cerebral palsy (CP). The resulting decrease in energy expenditure allows patients to gain much-needed weight, albeit temporarily. Modern techniques require sufficient abdominal musculature and subcutaneous fat to permit the implantation of an indwelling pump. In patients with extremely low muscle bulk, visceral pumps may be impractical or impossible, with increased risks of dehiscence and infection. The authors describe a variation of the classical procedure in a young patient with severe cachexia. A 10-year-old boy with spastic-dystonic quadriplegic CP was admitted to the neuromedical unit. Numerous drug trials had failed, and surgical intervention was deemed necessary but was complicated by his cachectic body habitus. The authors inserted a lumbar intrathecal catheter and subcutaneously tunneled it to the anterolateral abdomen, where it was connected to a subcutaneous injection port. Baclofen was continuously infused into the subcutaneous port using a noncoring needle connected to an external pump. The needle and line were changed every 5 days to minimize the risk of sepsis. Although other techniques, such as intraventricular baclofen delivery, have been described, these are largely dependent upon sufficient musculature to support a visceral pump. A subcutaneous injection port system represents an alternative approach that reduces the risk of sepsis and may be better tolerated in cachectic patients. PMID:25084089

  14. Finite element model of needle electrode sensitivity

    Science.gov (United States)

    Høyum, P.; Kalvøy, H.; Martinsen, Ø. G.; Grimnes, S.

    2010-04-01

    We used the Finite Element (FE) Method to estimate the sensitivity of a needle electrode for bioimpedance measurement. This current conducting needle with insulated shaft was inserted in a saline solution and current was measured at the neutral electrode. FE model resistance and reactance were calculated and successfully compared with measurements on a laboratory model. The sensitivity field was described graphically based on these FE simulations.

  15. Hollow sucker rod for PCP systems

    Energy Technology Data Exchange (ETDEWEB)

    Villasante, J.A.; Ernst, H.A. [Tenaris Research and Development, Campana (Argentina)

    2008-07-01

    This paper described a new hollow sucker rod technology designed for use with progressive cavity pumps (PCPs). The technology provided a high torque load to yielding ratio, as well as high backspin resistance and pumping rates. The technology was also designed to allow for the injection of other fluids such as corrosion inhibitors or diluents via its hollow sucker rod. Torsion, axial, and bending load stress analyses were conducted to determine critical zones in a top hollow rod connection at the well head and a bottom hollow rod connection at the well bottom. The study showed that the ratio between the equivalent stress and ultimate tensile stress was a function of torsional load. Backspin analyses were conducted to determine the release of energy accumulated in the hollow rod and traditional pumping system. The evaluation showed that the elastic torsional deformation was lower in the hollow rod system, while backspin resistance was higher. Multiple make and break operations were conducted to determine torsional load values. Results from the study were used to optimize the hollow rod technology. It was concluded that the hollow sucker rod system is now being used in various configurations at sites around the world. 8 tabs., 14 figs.

  16. Hollow cathode lamp-construction aspects

    International Nuclear Information System (INIS)

    The hollow cathode discharge is a source used for absorption and fluorescence atomic spectrophotometry. In this paper various aspect like construction, cleanliness and operation have been described. The life time of the hollow cathode discharge for specific current is about 500 hs. The range of current for the non significant self-absorption of the recommended wavelenght has been determinated. (Author)

  17. Hollow nanocrystals and method of making

    Science.gov (United States)

    Alivisatos, A. Paul; Yin, Yadong; Erdonmez, Can Kerem

    2011-07-05

    Described herein are hollow nanocrystals having various shapes that can be produced by a simple chemical process. The hollow nanocrystals described herein may have a shell as thin as 0.5 nm and outside diameters that can be controlled by the process of making.

  18. Dry needling versus acupuncture: the ongoing debate.

    Science.gov (United States)

    Zhou, Kehua; Ma, Yan; Brogan, Michael S

    2015-12-01

    Although Western medical acupuncture (WMA) is commonly practised in the UK, a particular approach called dry needling (DN) is becoming increasingly popular in other countries. The legitimacy of the use of DN by conventional non-physician healthcare professionals is questioned by acupuncturists. This article describes the ongoing debate over the practice of DN between physical therapists and acupuncturists, with a particular emphasis on the USA. DN and acupuncture share many similarities but may differ in certain aspects. Currently, little information is available from the literature regarding the relationship between the two needling techniques. Through reviewing their origins, theory, and practice, we found that DN and acupuncture overlap in terms of needling technique with solid filiform needles as well as some fundamental theories. Both WMA and DN are based on modern biomedical understandings of the human body, although DN arguably represents only one subcategory of WMA. The increasing volume of research into needling therapy explains its growing popularity in the musculoskeletal field including sports medicine. To resolve the debate over DN practice, we call for the establishment of a regulatory body to accredit DN courses and a formal, comprehensive educational component and training for healthcare professionals who are not physicians or acupuncturists. Because of the close relationship between DN and acupuncture, collaboration rather than dispute between acupuncturists and other healthcare professionals should be encouraged with respect to education, research, and practice for the benefit of patients with musculoskeletal conditions who require needling therapy. PMID:26546163

  19. Needle Insertion with Duty-Cycled Rotation into Multiple Media

    OpenAIRE

    Lehocky, Craig A.; Riviere, Cameron N.

    2012-01-01

    Thin, flexible needles can be steered along nonlinear paths to reach deep anatomical structures within the human body. This study builds upon previous work involving steering of bevel-tipped needles by inserting while rotating in a duty-cycled fashion. Here we investigate how needle material and radius, duty cycle, and tissue stiffness affect needle curvature. Needles were inserted into media while rotated at a specified duty cycle and the curvature was measured. A linear relationship between...

  20. Genetic Dissection of the Signaling Cascade that Controls Activation of the Shigella Type III Secretion System from the Needle Tip.

    Science.gov (United States)

    Murillo, I; Martinez-Argudo, I; Blocker, A J

    2016-01-01

    Many Gram-negative bacterial pathogens use type III secretion systems (T3SSs) for virulence. The Shigella T3SS consists of a hollow needle, made of MxiH and protruding from the bacterial surface, anchored in both bacterial membranes by multimeric protein rings. Atop the needle lies the tip complex (TC), formed by IpaD and IpaB. Upon physical contact with eukaryotic host cells, T3S is initiated leading to formation of a pore in the eukaryotic cell membrane, which is made of IpaB and IpaC. Through the needle and pore channels, further bacterial proteins are translocated inside the host cell to meditate its invasion. IpaD and the needle are implicated in transduction of the host cell-sensing signal to the T3S apparatus. Furthermore, the sensing-competent TC seems formed of 4 IpaDs topped by 1 IpaB. However, nothing further is known about the activation process. To investigate IpaB's role during T3SS activation, we isolated secretion-deregulated IpaB mutants using random mutagenesis and a genetic screen. We found ipaB point mutations in leading to defects in secretion activation, which sometimes diminished pore insertion and host cell invasion. We also demonstrated IpaB communicates intramolecularly and intermolecularly with IpaD and MxiH within the TC because mutations affecting these interactions impair signal transduction. PMID:27277624

  1. POROUS WALL, HOLLOW GLASS MICROSPHERES

    Energy Technology Data Exchange (ETDEWEB)

    Sexton, W.

    2012-06-30

    Hollow Glass Microspheres (HGM) is not a new technology. All one has to do is go to the internet and Google{trademark} HGM. Anyone can buy HGM and they have a wide variety of uses. HGM are usually between 1 to 100 microns in diameter, although their size can range from 100 nanometers to 5 millimeters in diameter. HGM are used as lightweight filler in composite materials such as syntactic foam and lightweight concrete. In 1968 a patent was issued to W. Beck of the 3M{trademark} Company for 'Glass Bubbles Prepared by Reheating Solid Glass Particles'. In 1983 P. Howell was issued a patent for 'Glass Bubbles of Increased Collapse Strength' and in 1988 H. Marshall was issued a patent for 'Glass Microbubbles'. Now Google{trademark}, Porous Wall, Hollow Glass Microspheres (PW-HGMs), the key words here are Porous Wall. Almost every article has its beginning with the research done at the Savannah River National Laboratory (SRNL). The Savannah River Site (SRS) where SRNL is located has a long and successful history of working with hydrogen and its isotopes for national security, energy, waste management and environmental remediation applications. This includes more than 30 years of experience developing, processing, and implementing special ceramics, including glasses for a variety of Department of Energy (DOE) missions. In the case of glasses, SRS and SRNL have been involved in both the science and engineering of vitreous or glass based systems. As a part of this glass experience and expertise, SRNL has developed a number of niches in the glass arena, one of which is the development of porous glass systems for a variety of applications. These porous glass systems include sol gel glasses, which include both xerogels and aerogels, as well as phase separated glass compositions, that can be subsequently treated to produce another unique type of porosity within the glass forms. The porous glasses can increase the surface area compared to &apos

  2. Robotic catheter cardiac ablation combining ultrasound guidance and force control

    OpenAIRE

    Kesner, Samuel Benjamin; Howe, Robert D.

    2014-01-01

    Cardiac catheters allow physicians to access the inside of the heart and perform therapeutic interventions without stopping the heart or opening the chest. However, conventional manual and actuated cardiac catheters are currently unable to precisely track and manipulate the intracardiac tissue structures because of the fast tissue motion and potential for applying damaging forces. This paper addresses these challenges by proposing and implementing a robotic catheter system that uses 3D ultras...

  3. Role of biofilm in catheter-associated urinary tract infection

    OpenAIRE

    Trautner, Barbara W.; Darouiche, Rabih O.

    2004-01-01

    The predominant form of life for the majority of microorganisms in any hydrated biologic system is a cooperative community termed a “biofilm.” A biofilm on an indwelling urinary catheter consists of adherent microorganisms, their extracellular products, and host components deposited on the catheter. The biofilm mode of life conveys a survival advantage to the microorganisms associated with it and, thus, biofilm on urinary catheters results in persistent infections that are resistant to antimi...

  4. Rat Indwelling Urinary Catheter Model of Candida albicans Biofilm Infection

    OpenAIRE

    Nett, Jeniel E.; Brooks, Erin G.; Cabezas-Olcoz, Jonathan; Sanchez, Hiram; Zarnowski, Robert; Marchillo, Karen; Andes, David R.

    2014-01-01

    Indwelling urinary catheters are commonly used in the management of hospitalized patients. Candida can adhere to the device surface and propagate as a biofilm. These Candida biofilm communities differ from free-floating Candida, exhibiting high tolerance to antifungal therapy. The significance of catheter-associated candiduria is often unclear, and treatment may be problematic considering the biofilm drug-resistant phenotype. Here we describe a rodent model for the study of urinary catheter-a...

  5. Fabrication of functional hollow carbon spheres with large hollow interior as active colloidal catalysts

    Institute of Scientific and Technical Information of China (English)

    Qiang Sun; Guanghui Wang; Wencui Li; Xiangqian Zhang; Anhui Lu

    2012-01-01

    In this study,we have established a facile method to synthesize functional hollow carbon spheres with large hollow interior,which can act as active colloidal catalysts.The method includes the following steps:first,hollow polymer spheres with large hollow interior were prepared using sodium oleate as the hollow core generator,and 2,4-dihydroxybenzoic acid and hexamethylene tetramine (HMT) as the polymer precursors under hydrothermal conditions; Fe3+ or Ag+ cations were then introduced into the as-prepared hollow polymer spheres through the carboxyl groups; finally,the hollow polymer spheres can be pseudomorphically converted to hollow carbon spheres during pyrolysis process,meanwhile iron or silver nanoparticles can also be formed in the carbon shell simultaneously.The structures of the obtained functional hollow carbon spheres were characterized by TEM,XRD,and TG.As an example,Ag-doped hollow carbon spheres were used as colloid catalysts which showed high catalytic activity in 4-nitrophenol reduction reaction.

  6. Encrusted and incarcerated urinary bladder catheter: what are the options?

    Directory of Open Access Journals (Sweden)

    Christopher C.K. Ho

    2010-11-01

    Full Text Available Urinary bladder catheter encrustations are known complications of long-term urinary catheterisation, which is commonly seen in clinical practice. These encrustations can impede deflation of the balloon and therefore cause problems in the removal of the catheter. The options in managing an encrusted and incarcerated urinary bladder catheter include extracorporeal shock wave lithotripsy and lithoclast. We describe here another technique of dealing with a stuck and encrustated catheter, via direct crushing of the encrustations with a rigid cystoscope inserted through a suprapubic cystostomy tract.

  7. Real-time multipoint gastrointestinal 19-fluorine catheter tracking

    OpenAIRE

    Hahn, Tobias; Kozerke, Sebastian; Schwizer, Werner; Fried, Michael; Boesiger, Peter; Steingoetter, Andreas

    2014-01-01

    PURPOSE: To develop MR based real-time gastrointestinal 19-Fluorine (19F) catheter tracking and visualization allowing for real-time detection and feedback of 3D catheter shape and movement as well as catheter-driven adjustments of 1H imaging geometry parameters. METHODS: Data were acquired on a 3T clinical system using 3D Golden Angle radial sampling. Two gastrointestinal catheters incorporating four fiducial 19F markers (65 or 50 µL marker volume) were tracked while being pulled through ...

  8. Analog experiment of transarterial catheter hyperthermic infusion in vitro

    International Nuclear Information System (INIS)

    Objective: To investigate the factors related to the heating effect by transarterial catheter hyperthermic infusion with the evaluation of the feasibility in controlling the tumor temperature. Methods: Infusing 55-68 degree C liquid at the speed of 10-40 ml/min through 6F, 5F or 3F catheter with different length respectively under the similar clinical condition. The liquid temperature at the terminal exit of the catheter was measured with a digital thermometer. The factors related to the liquid temperature at the exit of the catheter were analyzed by multiple regression analysis. Results: The infusion temperature , rate and the catheter length were the main related factors to the liquid temperature at the exit of the catheter as the condition similar in clinical use. When 60-65 degree C liquid was infused at the rate of 20-40 ml/min through 5F catheter with length of 80 cm, the mean and 95% confident interval of the liquid temperature at the catheter exit were (47.55±0.44) degree C and 44.61-48.49 degree C respectively. Conclusions: The liquid temperature at the exit of infusion catheter can be regulated and controlled through adjusting the liquid perfusion temperature and speed. (authors)

  9. Use of tunnelled catheters in haematological malignancy patients with neutropenia.

    Science.gov (United States)

    Sariosmanoglu, N; Uğurlu, B; Turgut, N H; Demirkan, F; Ozsan, H; Ergor, G; Gulay, Z; Hazan, E; Oto, O

    2008-01-01

    This prospective study analysed 83 patients (age 45 +/- 17 years) with haematological neoplasms, implanted with 93 tunnelled catheters, who were neutropenic or developed neutropenia during treatment. Catheters were implanted in the right (n = 82) or left (n = 11) jugular vein by the same surgical team using the same technique. They remained in place for 124 +/- 88 days: 29% were removed due to infection; 18% due to treatment termination and 2% due to mechanical problems. Seventeen patients died with catheters in place. At 30, 60, 90, 120 and 200 days mean catheter duration rates were 82%, 75%, 65%, 60% and 35%, respectively, and freedom from catheter removal due to infection was 92%, 88%, 80%, 77% and 67%, respectively. Patient diagnosis and history of previous catheter infection did not increase catheter infection risk, but patients undergoing stem cell transplantation had an increased infection risk. Tunnelled catheters can be used in high-risk patients with neutropenia. Systemic infections can be managed in most patients without catheter removal. PMID:18831907

  10. A prototype catheter designed for ultraviolet C disinfection

    DEFF Research Database (Denmark)

    Bak, Jimmy; Begovic, Tanja

    2013-01-01

    possible to design a single-lumen catheter with a hub, tube connector and tube parts that can be UVC-disinfected throughout its entire lumen. Methods Two single-lumen catheters were designed: one control and one for UVC exposure. They were contaminated with Pseudomonas aeruginosa (104–105 cfu/mL) before...... UVC light exposure, sampling and plate counting. Findings Two minutes of UVC exposure was sufficient to obtain 4 log10 disinfection for the full-length prototype catheter. This exposure corresponds to ∼40 mJ/cm2 at the catheter tip and indicates that even shorter exposure times can be achieved...

  11. Remote control catheter navigation: options for guidance under MRI

    Directory of Open Access Journals (Sweden)

    Muller Leah

    2012-06-01

    Full Text Available Abstract Background Image-guided endovascular interventions have gained increasing popularity in clinical practice, and magnetic resonance imaging (MRI is emerging as an attractive alternative to X-ray fluoroscopy for guiding such interventions. Steering catheters by remote control under MRI guidance offers unique challenges and opportunities. Methods In this review, the benefits and limitations of MRI-guided remote control intervention are addressed, and the tools for guiding such interventions in the magnetic environment are summarized. Designs for remote control catheter guidance include a catheter tip electromagnetic microcoil design, a ferromagnetic sphere-tipped catheter design, smart material-actuated catheters, and hydraulically actuated catheters. Remote control catheter guidance systems were compared and contrasted with respect to visualization, safety, and performance. Performance is characterized by bending angles achievable by the catheter, time to achieve bending, degree of rotation achievable, and miniaturization capacity of the design. Necessary improvements for furthering catheter design, especially for use in the MRI environment, are addressed, as are hurdles that must be overcome in order to make MRI guided endovascular procedures more accessible for regular use in clinical practice. Conclusions MR-guided endovascular interventions under remote control steering are in their infancy due to issues regarding safety and reliability. Additional experimental studies are needed prior to their use in humans.

  12. Percutaneous needle aspiration biopsy of chest lesions: effectiveness when using an 18-gauge needle

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Min; Jung, Gyoo Sik; Kim, So Sun; Huh, Jin Do; Joh, Young Duk; Huh, Bang [College of Medicine, Kosin National University, Busan (Korea, Republic of)

    1995-01-15

    Results of 181 percutaneous needle aspiration biopsies performed with an 18-gauge needle during a period of 3 years were analyzed to determine efficacy and safety of the procedure. Biposies were performed in patients that could not be diagnosed by bronchoscopy or sputum cytology. The biopsy procedure with 18-gauge Crown needle was guided by fluoroscopy. The biopsy specimen placed in 10% formalin solution were histologically confirmed. In 160 patients (89%), the positive diagnosis was made by percutaneous needle aspiration biopsy. There were 153 lung lesions (120 malignant and 33 benign lesions) and 7 mediastinal lesions. The diagnostic accuracy of malignant and benign disease was 91% and 80% respectively. Complications included pneumothorax (n = 11) and hemothorax (n = 1): six of them required treatment with chest tube and the remainder showed spontaneous resorption. PCNB with an 18-gauge needle provided a reliable, relatively safe diagnostic tool to establish the diagnosis of both malignant and benign chest lesions.

  13. Percutaneous needle aspiration biopsy of chest lesions: effectiveness when using an 18-gauge needle

    International Nuclear Information System (INIS)

    Results of 181 percutaneous needle aspiration biopsies performed with an 18-gauge needle during a period of 3 years were analyzed to determine efficacy and safety of the procedure. Biposies were performed in patients that could not be diagnosed by bronchoscopy or sputum cytology. The biopsy procedure with 18-gauge Crown needle was guided by fluoroscopy. The biopsy specimen placed in 10% formalin solution were histologically confirmed. In 160 patients (89%), the positive diagnosis was made by percutaneous needle aspiration biopsy. There were 153 lung lesions (120 malignant and 33 benign lesions) and 7 mediastinal lesions. The diagnostic accuracy of malignant and benign disease was 91% and 80% respectively. Complications included pneumothorax (n = 11) and hemothorax (n = 1): six of them required treatment with chest tube and the remainder showed spontaneous resorption. PCNB with an 18-gauge needle provided a reliable, relatively safe diagnostic tool to establish the diagnosis of both malignant and benign chest lesions

  14. Hollow Micro-/Nanostructures: Synthesis and Applications

    KAUST Repository

    Lou, Xiong Wen (David)

    2008-11-03

    Hollow micro-nanostructures are of great interest in many current and emerging areas of technology. Perhaps the best-known example of the former is the use of fly-ash hollow particles generated from coal power plants as partial replacement for Portland cement, to produce concrete with enhanced strength and durability. This review is devoted to the progress made in the last decade in synthesis and applications of hollow micro-nanostructures. We present a comprehensive overview of synthetic strategies for hollow structures. These strategies are broadly categorized into four themes, which include well-established approaches, such as conventional hard-templating and soft-templating methods, as well as newly emerging methods based on sacrificial templating and template-free synthesis. Success in each has inspired multiple variations that continue to drive the rapid evolution of the field. The Review therefore focuses on the fundamentals of each process, pointing out advantages and disadvantages where appropriate. Strategies for generating more complex hollow structures, such as rattle-type and nonspherical hollow structures, are also discussed. Applications of hollow structures in lithium batteries, catalysis and sensing, and biomedical applications are reviewed. © 2008 WILEY-VCH Verlag GmbH & Co. KGaA,.

  15. DIY guide-needle-assisted conjunctivodacryocystorhinostomy (CDCR).

    Science.gov (United States)

    Paik, Ji-Sun; Kim, Su-Ah; Doh, Sang-Hee

    2013-01-01

    In this study, we introduce DIY guide-needle-assisted conjunctivodacryocystorhinostomy (CDCR), in which a guide needle helps in measuring the initial Jones tube length for insertion and reduces unnecessary handling for tube changes. Three CDCR procedures were conducted in which the length of the Jones tube was calculated using a 22-gauge DIY guide needle, and a prospective study of tube position change and migration, (a major cause of CDCR failure) was done. Wound healing was almost complete within 4 weeks postoperatively in the osteotomy site, but in cases of partial middle turbinectomy, a little more time was necessary. There was a slight change in Jones tube position in the nasal cavity compared with the expected position of original tube tip, but no tube migration from the caruncle fixation position had occurred by the final follow-up time. This guide-needle-assisted CDCR has multiple advantages, such as easy measurement of the proper initial tube size, utilization of the initial needle path, and easy replacement of tubes. Finally, this approach to CDCR can be readily applied because it uses materials ordinarily found in hospitals to create the devices needed for the procedure, so there is no additional cost. PMID:22526574

  16. Medically relevant ElectroNeedle technology development.

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Carrie Frances; Thomas, Michael Loren; McClain, Jaime L.; Harper, Jason C.; Achyuthan, Komandoor E.; Ten Eyck, Gregory A.

    2008-11-01

    ElectroNeedles technology was developed as part of an earlier Grand Challenge effort on Bio-Micro Fuel Cell project. During this earlier work, the fabrication of the ElectroNeedles was accomplished along with proof-of-concept work on several electrochemically active analytes such as glucose, quinone and ferricyanide. Additionally, earlier work demonstrated technology potential in the field of immunosensors by specifically detecting Troponin, a cardiac biomarker. The current work focused upon fabrication process reproducibility of the ElectroNeedles and then using the devices to sensitively detect p-cresol, a biomarker for kidney failure or nephrotoxicity. Valuable lessons were learned regarding fabrication assurance and quality. The detection of p-cresol was accomplished by electrochemistry as well as using fluorescence to benchmark ElectroNeedles performance. Results from these studies will serve as a guide for the future fabrication processes involving ElectroNeedles as well as provide the groundwork necessary to expand technology applications. One paper has been accepted for publication acknowledging LDRD funding (K. E. Achyuthan et al, Comb. Chem. & HTS, 2008). We are exploring the scope for a second paper describing the applications potential of this technology.

  17. Method for producing small hollow spheres

    International Nuclear Information System (INIS)

    A method is described for producing small hollow spheres of glass, metal or plastic, wherein the sphere material is mixed with or contains as part of the composition a blowing agent which decomposes at high temperature (T >approx. 6000C). As the temperature is quickly raised, the blowing agent decomposes and the resulting gas expands from within, thus forming a hollow sphere of controllable thickness. The thus produced hollow spheres (20 to 103μm) have a variety of application, and are particularly useful in the fabrication of targets for laser implosion such as neutron sources, laser fusion physics studies, and laser initiated fusion power plants

  18. Microring embedded hollow polymer fiber laser

    International Nuclear Information System (INIS)

    Strongly modulated laser emission has been observed from rhodamine B doped microring resonator embedded in a hollow polymer optical fiber by transverse optical pumping. The microring resonator is fabricated on the inner wall of a hollow polymer fiber. Highly sharp lasing lines, strong mode selection, and a collimated laser beam are observed from the fiber. Nearly single mode lasing with a side mode suppression ratio of up to 11.8 dB is obtained from the strongly modulated lasing spectrum. The microring embedded hollow polymer fiber laser has shown efficient lasing characteristics even at a propagation length of 1.5 m

  19. Fabricating a hollow bulb obturator

    Directory of Open Access Journals (Sweden)

    Fatih Sari

    2012-01-01

    Full Text Available

    Obturators are generally used in the rehabilitation of the maxillectomy defects. Ideally, obturators should be light, properly fit and construction should be made easily. By decreasing the weight of the prosthesis, the retention and stability may be optimized to allow the obturator for function comfortably during mastication, phonation, and deglutition. In this case, a 65-year-old male patient underwent surgical removal of left part of the maxilla due to the squamous cell carcinoma. In this technique fabrication of a hollow bulb obturator prosthesis as a single unit in heat-cured acrylic resin using a single-step flasking procedure was described. The patient’s functional and esthetic expectations were satisfied.

  20. Hollow-core tapered coupler for large inner diameter hollow-core optical fibers

    Institute of Scientific and Technical Information of China (English)

    Guiyao Zhou(周桂耀); Zhiyun Hou(侯峙云); Lantian Hou(侯蓝田); Jigang Liu(刘继刚)

    2003-01-01

    A novel hollow-core tapered coupler has been theoretically designed and fabricated by fiber drawing machine. The coupler's inner wall is coated with a polycrystalline GeO2 film. The coupling loss of hollow-core tapered coupler is about 0.2 dB. Hollow-core tapered coupler reduces the transmission loss of hollow-core optical fiber (HCOF) by 0.5 dB/m, therefore the coupler is suitable for coupling high power CO2 laser in industrial application.

  1. Evaluation of a novel Seldinger-needle for computed tomography guided interventions: initial experiences; Evaluierung einer neuen Seldinger-Nadel fuer computertomografisch gesteuerte Interventionen: Erste Erfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Plumhans, C.; Mahnken, A.; Iwa, R.; Behrendt, F.F.; Sebastian, K.; Guenther, R.W.; Honnef, D. [Universitaetsklinikum RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2009-02-15

    To evaluate a new Seldinger puncture device for computed tomography-guided interventions under difficult conditions, to analyze applicability, and to investigate assets and drawbacks. From November 2007 to March 2008, we performed CT-guided interventions in 16 patients (7 women, 9 men; mean age 62 years old) using a new 20G-Seldinger needle (Sika-Med, Wiehl, Germany). This novel needle serves as a guide for many different interventional devices due to a guide wire welded on the proximal needle end. It allows continuous application of anesthesia via four tiny holes at the distal needle end until the region of interest is reached. Each intervention was subject to difficult interventional conditions. The indications for intervention were drainage (n = 7), Trucut biopsy of tumor (n = 8) and radiofrequency ablation (n = 1). Handling, success, advantages, drawbacks, complications and patient tolerance were noted after each procedure. A pain scale from 1 - 10 was used to grade the pain level during the intervention. All interventions were performed successfully and no severe complications were observed. Patient tolerance was very good resulting in a mean pain score of 2 {+-} 1. Regions with dangerous and difficult access were successfully reached with the new Seldinger needle in 15 of 16 cases by dilatation of the puncture tract and continuous administration of local anesthesia via the system. Furthermore, different devices such as Trucut systems and a drainage catheter were able to be inserted without complication via the needle. With a proximal removable luer-lock connection, liquid material was able to be aspirated in six cases. Under difficult interventional conditions, the use of a Seldinger needle as a reliable technique for CT-guided interventions can provide a safe and successful procedure. (orig.)

  2. ["Sham Needle"--Design and Application of A Double-blind Placebo Needle Assembly].

    Science.gov (United States)

    Yan, Liu; Ma, Li-hong

    2016-02-01

    The blind study design, particularly the double-blind study design is a very important method for diminishing placebo effect and reducing bias in clinical medical trial. Enlightened by Streitberger's and Park's sham needle design, the authors of the present paper introduce a newly designed sham needle device (Yan's sham-needle) for controlled double-blind trials of acupuncture. This sham needle device consists of needle, tube and base. The bottom of the tube is completely sealed and it can never arouse any invasive stimulation on the subject's skin when the sham needle is downward pressed on the body surface. Meanwhile, this sham device is filled with sponge which is able to simulate soft tissues of the acupoint area. By combining words suggestions or hints before trials and the same shape as verum device, this sham-needle device reduces the risk of blind-breaking and makes it possible to conduct controlled double-blind trials. Primary practice showed that this device may provide a new and practical tool for researching the placebo effect of acupuncture therapy. PMID:27141628

  3. Comparison of Standard Catheters Versus Radial Artery-Specific Catheter in Patients Who Underwent Coronary Angiography Through Transradial Access.

    Science.gov (United States)

    Chen, On; Goel, Sunny; Acholonu, Michael; Kulbak, Guy; Verma, Shivani; Travlos, Efstratios; Casazza, Richard; Borgen, Elliot; Malik, Bilal; Friedman, Michael; Moskovits, Norbert; Frankel, Robert; Shani, Jacob; Ayzenberg, Sergey

    2016-08-01

    In this prospective, randomized controlled study, we aim to compare the performance outcomes of standard catheters with the radial artery-specific catheter. Over the past decade, transradial cardiac catheterization has gained widespread popularity because of its low complication rates compared with transfemoral access. Operators have the choice of using either standard catheters (used for both transfemoral and transradial approach, with need for separate catheter use for either right or left coronary artery engagement) or a dedicated radial artery catheter, which is specifically designed to engage both coronary arteries through radial artery access. A total of 110 consecutive patients who underwent coronary angiography at our institution from March 2015 to April 2015 were prospectively randomized to either radial artery-specific Tiger catheter (5Fr; Terumo Interventional Systems, Somerset, New Jersey) versus standard Judkins left and right catheters (5Fr R4, L4; Cordis Corporation, Miami, Florida). The end points of the study included fluoroscopy time, dose-area product, contrast volume used, and total procedure time for the coronary angiography. A total of 57 patients (52%) were randomized to radial artery-specific catheter and 53 (48%) to the standard catheter. Tiger catheter was associated with significantly lower fluoroscopy time (184 ± 91 vs 238 ± 131 seconds, p = 0.015), which was statistically significant. Other outcome measures such as dose-area product (2,882.4 ± 1,471.2 vs 3,524.6 ± 2,111.7 Gy·cm(2), p = 0.07), total contrast volume (48.1 ± 16.1 vs 53.4 ± 18.5 ml, p = 0.114), and total procedure time (337 ± 382 vs 434 ± 137 seconds, p = 0.085) were also lower in single-catheter group, but it did not reach statistical significance. A total of 8 patients (14%) were crossed over from radial-specific catheter arm to standard catheter arm because of substandard image quality and difficulty in coronary engagement. Six patients had to be

  4. Monitoring Atrial Fibrillation After Catheter Ablation

    Directory of Open Access Journals (Sweden)

    Giovanni B Forleo, MD PhD; MAssimo Moltrasio, MD; Michela Casella MD, PhD; Antonio Dello Russo MD, PhD; Getano Fassini, MD; Manfredi Tesauro, MD, PhD; Claudio Tondo, MD, PhD.

    2014-04-01

    Full Text Available Although catheter ablation is an effective treatment for recurrent atrial fibrillation (AF, there is no consensus on the definition of success or follow-up strategies. Symptoms are the major motivation for undergoing catheter ablation in patients with AF, however it is well known that reliance on perception of AF by patients after AF ablation results in an underestimation of recurrence of the arrhythmia. Because symptoms of AF occurrence may be misleading, a reliable assessment of rhythm outcome is essential for the definition of success in both clinical care and research trials. Continuous rhythm monitoring over long periods of time is superior to intermittent recording using external monitors to detect the presence of AF episodes and to quantify the AF burden. Today, new devices implanted subcutaneously using a minimally invasive technique have been developed for continuous AF monitoring. Implantable devices keep detailed information about arrhythmia recurrences and might allow identification of very brief episodes of AF, the significance of which is still uncertain. In particular, it is not known whether there is any critical value of daily AF burden that has a prognostic significance. This issue remains an area of active discussion, debate and investigation. Further investigation is required to determine if continuous AF monitoring with implantable devices is effective in reducing stroke risk and facilitating maintenance of sinus rhythm after AF ablation.

  5. Engineering Considerations Of Catheters For Intravascular Ultrasonic Measurements

    Science.gov (United States)

    Martin, Roy W.; Johnson, Christopher C.

    1989-08-01

    The mechanical properties of commonly used fluid transfusion or pressure monitoring catheters are similar to the properties required of catheters which include sensing devices. Consequently, bending and torsional stiffness of commercial catheters and tubes were measured at both room and body temperature. Five of these usually placed with the aid of fluoroscopy had an average Young's modulus of 5714x101 dyne/cm at 21°C which decreased 29% at body temperature; a shear modulus of 70.5x101 dyne/cm 4 at 21°C which decreased 13% at body temperature, and plastic deformation of 8% when loaded for 1 minute at 37°. Four of these were composed of a composite material. Catheters which are balloon directed during insertion had moduli values approximately 1/3 of these or less. The drag forces produced on balloons used on such catheters were measured for fluid velocities ranging from 10-50 cm/sec. Using this information the average force applied to a balloon throughout a cardiac cycle was calculated; values of 1280 dynes for a .6 ml balloon and 2490 dynes for a 1 ml balloon were found. The maximum wall thicknesses to catheter radii for single lumen catheters were determined for various material moduli which would allow the catheter tip to be directed by a balloon during its passage into the right heart.

  6. Syringe and Needle Size, Syringe Type, Vacuum Generation, and Needle Control in Aspiration Procedures

    International Nuclear Information System (INIS)

    Purpose: Syringes are used for diagnostic fluid aspiration and fine-needle aspiration biopsy in interventional procedures. We determined the benefits, disadvantages, and patient safety implications of syringe and needle size on vacuum generation, hand force requirements, biopsy/fluid yield, and needle control during aspiration procedures. Materials and Methods: Different sizes (1, 3, 5, 10, and 20 ml) of the conventional syringe and aspirating mechanical safety syringe, the reciprocating procedure device, were studied. Twenty operators performed aspiration procedures with the following outcomes measured: (1) vacuum (torr), (2) time to vacuum (s), (3) hand force to generate vacuum (torr-cm2), (4) operator difficulty during aspiration, (5) biopsy yield (mg), and (6) operator control of the needle tip position (mm). Results: Vacuum increased tissue biopsy yield at all needle diameters (P < 0.002). Twenty-milliliter syringes achieved a vacuum of −517 torr but required far more strength to aspirate, and resulted in significant loss of needle control (P < 0.002). The 10-ml syringe generated only 15% less vacuum (−435 torr) than the 20-ml device and required much less hand strength. The mechanical syringe generated identical vacuum at all syringe sizes with less hand force (P < 0.002) and provided significantly enhanced needle control (P < 0.002). Conclusions: To optimize patient safety and control of the needle, and to maximize fluid and tissue yield during aspiration procedures, a two-handed technique and the smallest syringe size adequate for the procedure should be used. If precise needle control or one-handed operation is required, a mechanical safety syringe should be considered.

  7. King Injo's Disease and Burnt Needle Therapy

    Directory of Open Access Journals (Sweden)

    KIM In-Sook

    2004-12-01

    Full Text Available This paper investigates an interrelationship between burnt needle therapy(번침 and King Injo'sdisease. From 1633 (Year 11 in King Injo's reign to May 5, 1649 (Year 27 King in Injo's reign, right before his death, King Injo(인조 was treated with burnt needles by Yi Hyeongik(이형익, an acupuncturist when the king had health problems. This study arises from two questions: why was King Injo often treated with burnt needles? and what effect did burnt needles have? Burnt needle therapy is a combined form of acupuncture and moxibustion. Yi Hyeongik was famous for eradicating pathogenic factors. He was appointed as a doctor in the Royal Hospital. The medical definition for pathogenic factors is that they are disease-causing factors. Understanding the pathogenic factor for King Injo's disease could make it possible to find the interrelationship between burnt needles and the king's disease. In the Joseon era, the prevalent belief about diseases was that diseases could be caused by homeopathic magic. Some people thought homeopathic magic caused King Injo's disease.  The actual reasons for King Injo's disease were the participation in the excessive rites of Queen Mother Inmok's funeral and the constant oppression from the Ching Dynasty after disgraceful defeat in the war. When King Injo started to be sick, homeopathic magic cases were found in the royal palace. The king's incurable disease was believed to have happened as a result of homeopathic magic. King Injo's suspicion toward Princess Jeongmyeong(정명공주 derived from her mother, Queen Mother Inmok(인목대비. Moral justification for King Injo's coup was Gwanghaegun(광해군 or Prince Gwanghae's immoral conduct toward Queen Mother Inmok. After he was installed, King Injo obeyed the Queen Mother and showed her every attention. Meanwhile, he treated Princess Jeongmyeong with respect, maximized the moral justification for the coup, and solidified the royal authority. However, constant

  8. Hollow rhodoliths increase Svalbard's shelf biodiversity

    Science.gov (United States)

    Teichert, Sebastian

    2014-11-01

    Rhodoliths are coralline red algal assemblages that commonly occur in marine habitats from the tropics to polar latitudes. They form rigid structures of high-magnesium calcite and have a good fossil record. Here I show that rhodoliths are ecosystem engineers in a high Arctic environment that increase local biodiversity by providing habitat. Gouged by boring mussels, originally solid rhodoliths become hollow ecospheres intensely colonised by benthic organisms. In the examined shelf areas, biodiversity in rhodolith-bearing habitats is significantly greater than in habitats without rhodoliths and hollow rhodoliths yield a greater biodiversity than solid ones. This biodiversity, however, is threatened because hollow rhodoliths take a long time to form and are susceptible to global change and anthropogenic impacts such as trawl net fisheries that can destroy hollow rhodoliths. Rhodoliths and other forms of coralline red algae play a key role in a plurality of environments and need improved management and protection plans.

  9. Collimation Studies with Hollow Electron Beams

    Energy Technology Data Exchange (ETDEWEB)

    Stancari, G.; Annala, G.; Johnson, T.R.; Saewert, G.W.; Shiltsev, V.; Still, D.A.; Valishev, A.; /Fermilab

    2011-08-01

    Recent experimental studies at the Fermilab Tevatron collider have shown that magnetically confined hollow electron beams can act as a new kind of collimator for high-intensity beams in storage rings. In a hollow electron beam collimator, electrons enclose the circulating beam. Their electric charge kicks halo particles transversely. If their distribution is axially symmetric, the beam core is unaffected. This device is complementary to conventional two-stage collimation systems: the electron beam can be placed arbitrarily close to the circulating beam; and particle removal is smooth, so that the device is a diffusion enhancer rather than a hard aperture limitation. The concept was tested in the Tevatron collider using a hollow electron gun installed in one of the existing electron lenses. We describe some of the technical aspects of hollow-beam scraping and the results of recent measurements.

  10. Mode characteristics of hollow core Bragg fiber

    Institute of Scientific and Technical Information of China (English)

    Minning Ji; Zhidong Shi; Qiang Guo

    2005-01-01

    Analytical expression to calculate propagation constant and mode field of the hollow core Bragg fiber is derived. Numerical results are presented. It is shown that the fundamental mode of the hollow core Bragg fiber is circularly symmetric TE01 mode with no polarization degeneracy, while the higher order mode may be HE11, TM01, or TE02 etc.. This property is different from conventional optical fiber that its fundamental mode is the linearly polarized HE11 mode and is polarization degeneracy.

  11. Vibration Analysis of Hollow Tapered Shaft Rotor

    OpenAIRE

    P. M. G. Bashir Asdaque; Behera, R. K.

    2014-01-01

    Shafts or circular cross-section beams are important parts of rotating systems and their geometries play important role in rotor dynamics. Hollow tapered shaft rotors with uniform thickness and uniform bore are considered. Critical speeds or whirling frequency conditions are computed using transfer matrix method and then the results were compared using finite element method. For particular shaft lengths and rotating speeds, response of the hollow tapered shaft-rotor system is determined for t...

  12. Determination of the Stoichiometry of the Complete Bacterial Type III Secretion Needle Complex Using a Combined Quantitative Proteomic Approach.

    Science.gov (United States)

    Zilkenat, Susann; Franz-Wachtel, Mirita; Stierhof, York-Dieter; Galán, Jorge E; Macek, Boris; Wagner, Samuel

    2016-05-01

    Precisely knowing the stoichiometry of their components is critical for investigating structure, assembly, and function of macromolecular machines. This has remained a technical challenge in particular for large, hydrophobic membrane-spanning protein complexes. Here, we determined the stoichiometry of a type III secretion system of Salmonella enterica serovar Typhimurium using two complementary protocols of gentle complex purification combined with peptide concatenated standard and synthetic stable isotope-labeled peptide-based mass spectrometry. Bacterial type III secretion systems are cell envelope-spanning effector protein-delivery machines essential for colonization and survival of many Gram-negative pathogens and symbionts. The membrane-embedded core unit of these secretion systems, termed the needle complex, is composed of a base that anchors the machinery to the inner and outer membranes, a hollow filament formed by inner rod and needle subunits that serves as conduit for substrate proteins, and a membrane-embedded export apparatus facilitating substrate translocation. Structural analyses have revealed the stoichiometry of the components of the base, but the stoichiometry of the essential hydrophobic export apparatus components and of the inner rod protein remain unknown. Here, we provide evidence that the export apparatus of type III secretion systems contains five SpaP, one SpaQ, one SpaR, and one SpaS. We confirmed that the previously suggested stoichiometry of nine InvA is valid for assembled needle complexes and describe a loose association of InvA with other needle complex components that may reflect its function. Furthermore, we present evidence that not more than six PrgJ form the inner rod of the needle complex. Providing this structural information will facilitate efforts to obtain an atomic view of type III secretion systems and foster our understanding of the function of these and related flagellar machines. Given that other virulence

  13. A new method to repair the ruptured silicone PICC catheter%硅胶材质 PICC 导管破损的修复新方法

    Institute of Scientific and Technical Information of China (English)

    喻燕敏; 徐思思; 姚伟荣

    2014-01-01

    目的:探讨新型方法修复断裂的BD PICC导管。方法:选择导管破损患者2例,导管送管困难患者3例,在无菌操作下,将断裂的原导管轻轻向外拖移3 cm,用无菌剪刀将破裂导管尾部剪去,先将巴德导管末端连接器的减压套筒穿过留在体外的导管,然后再将导管与针芯柄对扣锁住。结果:2例导管破损患者使用该方法成功修复,在后续使用中均未出现漏液、脱落、堵管、感染。2例使用时间超过210 d,现仍在带管中。3例因送管困难患者中,1例留置216 d,后因死亡拔管;2例留置30 d拔管。结论:该种修复方法安全有效,值得临床推广应用。%Explored a new method to repair the ruptured BD silicone PICC catheter .Methods:The ruptured catheter was pulled gently outward 3 cm and the tail of ruptured catheter was cut off .Then the end connection device of Bard PICC catheter was moved through the ruptured catheter staying out-side of the body.The catheter and the core needle were jointed and the repairment was finished .Results:Two ruptured silicone PICC catheters were repaired successfully using this method and no leakage,separation,plugging and infection was observed in the subsequent use,they had used the repaired catheters more than 210 days.1 patient used 216 days and 2 patients used 30 days amang 3 patients with difficulty sending pipe .Conclusion:The repairing method mentioned in this paper was safe and useful.It is worth to be promoted.

  14. Urethral catheter insertion forces: a comparison of experience and training

    Directory of Open Access Journals (Sweden)

    Benjamin K. Canales

    2009-02-01

    Full Text Available Purpose: This study was undertaken to evaluate the insertion forces utilized during simulated placement of a urethral catheter by healthcare individuals with a variety of catheter experience. Materials and Methods: A 21F urethral catheter was mounted to a metal spring. Participants were asked to press the tubing spring against a force gauge and stop when they met a level of resistance that would typically make them terminate a catheter placement. Simulated catheter insertion was repeated fives times, and peak compression forces were recorded. Healthcare professionals were divided into six groups according to their title: urology staff, non-urology staff, urology resident/ fellow, non-urology resident/ fellow, medical student, and registered nurse. Results: A total of fifty-seven healthcare professionals participated in the study. Urology staff (n = 6 had the lowest average insertion force for any group at 6.8 ± 2.0 Newtons (N. Medical students (n = 10 had the least amount of experience (1 ± 0 years and the highest average insertion force range of 10.1 ± 3.7 N. Health care workers with greater than 25 years experience used significantly less force during catheter insertions (4.9 ± 1.8 N compared to all groups (p < 0.01. Conclusions: We propose the maximum force that should be utilized during urethral catheter insertion is 5 Newtons. This force deserves validation in a larger population and should be considered when designing urethral catheters or creating catheter simulators. Understanding urethral catheter insertion forces may also aid in establishing competency parameters for health care professionals in training.

  15. Efficacy of preventing hemodialysis catheter infections with citrate lock.

    Science.gov (United States)

    Silva, Jorge; Antunes, Jorge; Carvalho, Telmo; Ponce, Pedro

    2012-10-01

    Prevalent use of tunneled dialysis catheters can reach 30%. Infection remains the most serious catheter-related problem. Catheter locks are increasingly used for prevention, but are not yet recommended either by the Food and Drug Association or European Medicines Agency, on the basis of increasing bacterial resistance or lock toxicity. The aim was to test safety and effectiveness of citrate. A prospective, interventional study was conducted to assess the safety and efficacy of a 30% citrate lock in preventing catheter-related bacteremia (CRB). A total of 157 prevalent tunneled catheters were locked with citrate and prospectively followed during a 1-year period. The primary endpoint was first CRB diagnosed according to two of the diagnostic criteria for Catheter Infection of Centers for Disease Control and Prevention (CDC), namely definite and probable infection. The CDC criterion of possible but not proved infection was not considered. This citrate lock cohort (n = 157) had 10 episodes of CRB. We observed 0.49 CRB episodes/1000 patient-days and the mean infection-free catheter day was 130.6 ± 100.9. No clinically relevant adverse events were observed. No proved tunnel or exit site infection was observed and no patients died because of CRB. Catheter obstruction episodes were reported on 69 occasions out of 14 catheters. These results were compared with an historical cohort from a previous study of catheter locking with low-dose gentamicin and did not show significant difference in efficacy. Citrate lock is effective in preventing CRB. No toxicity was observed. The use of citrate lock may have advantages over antibiotic locks: no reported bacterial resistance, lower industrial cost, and less manipulation. PMID:22515732

  16. Value of Micronester coils in port-catheter implantation for continuous hepatic arterial infusion chemotherapy with fixed catheter tip method

    Energy Technology Data Exchange (ETDEWEB)

    Yamagami, Takuji; Kato, Takeharu; Hirota, Tatsuya; Yoshimatsu, Rika; Matsumoto, Tomohiro; Nishimura, Tsunehiko [Kyoto Prefectural University of Medicine, Department of Radiology, Graduate School of Medical Science, Kyoto (Japan); White, Robert I. [Yale University School of Medicine, Department of Diagnostic Radiology, New Haven, CT (United States)

    2008-01-15

    To retrospectively evaluate the use of Micronester coils in port-catheter implantation with the fixed catheter tip method in comparison with other previously used coils. The cohort of this study was 143 consecutive patients with unresectable advanced liver cancer for whom a port-catheter system was percutaneously implanted. In the most recent 32 patients, Micronester coils were used for catheter tip fixation. Details of embolic agents for fixation, persistent blood flow beyond the distal end of the indwelling catheter, and complications were compared between cases without and with Micronester coils. In all, percutaneous port-catheter placement was successful. Mean number of coils used for fixation was 4.2 without Micronester coils vs. 2.5 with Micronester coils. N-butyl cyanoacrylate (NBCA)-Lipiodol was additionally used for catheter tip fixation in 85.6% of 111 procedures without Micronester coils and in 50% of 32 using Micronester coils. The gastroduodenal artery beyond the distal end was not detected at the final examination after any procedure. Catheter dislocation occurred in five and hepatic arterial obstruction or severe stenosis in eight. The number of coils used and necessity of NBCA-Lipiodol could be decreased with usage of Micronester coils without decreasing fixation ability compared to other coils. (orig.)

  17. Value of Micronester coils in port-catheter implantation for continuous hepatic arterial infusion chemotherapy with fixed catheter tip method

    International Nuclear Information System (INIS)

    To retrospectively evaluate the use of Micronester coils in port-catheter implantation with the fixed catheter tip method in comparison with other previously used coils. The cohort of this study was 143 consecutive patients with unresectable advanced liver cancer for whom a port-catheter system was percutaneously implanted. In the most recent 32 patients, Micronester coils were used for catheter tip fixation. Details of embolic agents for fixation, persistent blood flow beyond the distal end of the indwelling catheter, and complications were compared between cases without and with Micronester coils. In all, percutaneous port-catheter placement was successful. Mean number of coils used for fixation was 4.2 without Micronester coils vs. 2.5 with Micronester coils. N-butyl cyanoacrylate (NBCA)-Lipiodol was additionally used for catheter tip fixation in 85.6% of 111 procedures without Micronester coils and in 50% of 32 using Micronester coils. The gastroduodenal artery beyond the distal end was not detected at the final examination after any procedure. Catheter dislocation occurred in five and hepatic arterial obstruction or severe stenosis in eight. The number of coils used and necessity of NBCA-Lipiodol could be decreased with usage of Micronester coils without decreasing fixation ability compared to other coils. (orig.)

  18. Scar endometriosis: Diagnosis by fine needle aspiration

    OpenAIRE

    Pachori, Geeta; Sharma, Rashmi; Sunaria, Ravi Kant; Bayla, Tushar

    2015-01-01

    Endometriosis is defined as the presence of a functioning endometrium outside the uterus. Abdominal wall endometriosis is a rare entity. Most of the abdominal wall endometriosis occurs in or around surgical scars following caesarean section or hysterectomy. We report a case of scar endometriosis following caesarean section and diagnosed by fine needle aspiration cytology (FNAC). Excision biopsy confirmed the FNAC diagnosis of scar endometriosis.

  19. The Single Needle Lockstitch Machine. Module 1.

    Science.gov (United States)

    South Carolina State Dept. of Education, Columbia. Office of Vocational Education.

    This module on parts of the machine, one in a series on the single needle lockstitch sewing machine for student self-study, contains eight sections. Each section contains the following parts: an introduction, directions, an objective, learning activities, student information, student self-check, check-out activities, and an instructor's final…

  20. Thin needle aspiration biopsy of endocrine organs.

    Science.gov (United States)

    Koss, L G

    1979-01-01

    The purpose of this paper is to summarize the advantages and disadvantages of the fine needle aspiration technique in reference to the endocrine organs. The principles of technique and interpretation are presented. The application of aspiration biopsies to the breast, the prostate, the pancreas and the thyroid are briefly discussed. PMID:485094

  1. Particulate contamination of sterile syringes and needles.

    Science.gov (United States)

    Taylor, S A

    1982-08-01

    Commercially available sterile needles and syringes have been examined for particulate contamination using the Hiac light blockage technique. The number of particles delivered was small compared with the total number permitted for large volume parenterals. Where syringes are used in particle counting techniques, the contribution of particles should be taken into account. PMID:6126558

  2. 21 CFR 868.5150 - Anesthesia conduction needle.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction needle. 868.5150 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5150 Anesthesia conduction needle. (a) Identification. An anesthesia conduction needle is a device used to inject local anesthetics into a patient...

  3. Mechanics of Flexible Needles Robotically Steered through Soft Tissue

    NARCIS (Netherlands)

    Misra, S.; Reed, K.B.; Schafer, B.W.; Ramesh, K.T.; Okamura, A.M.

    2010-01-01

    The tip asymmetry of a bevel-tip needle results in the needle naturally bending when it is inserted into soft tissue. This enables robotic needle steering, which can be used in medical procedures to reach subsurface targets inaccessible by straight-line trajectories. However, accurate path planning

  4. 21 CFR 884.6100 - Assisted reproduction needles.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Assisted reproduction needles. 884.6100 Section... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction Devices § 884.6100 Assisted reproduction needles. (a) Identification. Assisted reproduction needles are devices used in...

  5. A computational modeling study on the helium atmospheric pressure plasma needle discharge

    Science.gov (United States)

    Qian, Mu-Yang; Yang, Cong-Ying; Liu, San-Qiu; Wang, Zhen-Dong; Lv, Yan; Wang, De-Zhen

    2015-12-01

    A two-dimensional coupled model of neutral gas flow and plasma dynamics is employed to investigate the streamer dynamics in a helium plasma needle at atmospheric pressure. A parametric study of the streamer propagation as a function of needle tip curvature radius and helium gas flow rate is presented. The key chemical reactions at the He/air mixing layer which drive the streamer propagation are the direct ionization via collision with electrons, the Penning effect being not so crucial. With increasing the gas flow rate from 0.2 standard liter per minute (SLM) to 0.8 SLM, however, the emissions resulting from reactive oxygen and nitrogen species change from a solid circle to a hollow profile and the average streamer propagation velocity decreases. Air impurities (backdiffusion from ambient air) in the helium jet result in a significant increase in the streamer propagation velocity. Besides, with decreasing the tip curvature radiusfrom 200 μm to 100 μm, the electron avalanche process around the near-tip region is more pronounced. However, the spatially resolved plasma parameters distributions (electron, helium metastables, ground state atomic oxygen, etc.) remain almost the same, except that around the near-tip region where their peak values are more than doubled. Project supported partly by the National Natural Science Foundation of China (Grant No. 11465013), the Natural Science Foundation of Jiangxi Province, China (Grant No. 20151BAB212012), and in part by the International Science and Technology Cooperation Program of China (Grant No. 2015DFA61800).

  6. Needle core biopsy for breast lesions: An audit of 467 needle core biopsies

    OpenAIRE

    Selvi Radhakrishna; Anu Gayathri; Deepa Chegu

    2013-01-01

    Background: Breast cancer is the commonest cancer among women in urban India. Triple assessment includes clinical, radiological and cytological assessment of breast lesions. Guided core needle biopsy has replaced fine needle aspiration cytology in most of the western countries. In resource poor countries FNAC is still a very valuable and cost effective method to diagnose breast lesions. Pitfalls include increased rates of non diagnostic smears, and inadequate smears. Further procedures may be...

  7. Distributed parameter statics of magnetic catheters.

    Science.gov (United States)

    Tunay, Ilker

    2011-01-01

    We discuss how to use special Cosserat rod theory for deriving distributed-parameter static equilibrium equations of magnetic catheters. These medical devices are used for minimally-invasive diagnostic and therapeutic procedures and can be operated remotely or controlled by automated algorithms. The magnetic material can be lumped in rigid segments or distributed in flexible segments. The position vector of the cross-section centroid and quaternion representation of an orthonormal triad are selected as DOF. The strain energy for transversely isotropic, hyperelastic rods is augmented with the mechanical potential energy of the magnetic field and a penalty term to enforce the quaternion unity constraint. Numerical solution is found by 1D finite elements. Material properties of polymer tubes in extension, bending and twist are determined by mechanical and magnetic experiments. Software experiments with commercial FEM software indicate that the computational effort with the proposed method is at least one order of magnitude less than standard 3D FEM. PMID:22256282

  8. Modified multipurpose catheter enhances clinical utility for cardiac catheterizations.

    Science.gov (United States)

    Mannino, S C; Scavina, M; Palmer, S

    1994-10-01

    The Multipurpose technique for coronary arteriography employs a single catheter. The benefits are a reduction in the cost of the procedure and a shorter procedural time by experienced operators. To enhance the performance of these catheters, a modification was made in the materials and tip design, and these modifications were clinically evaluated in a small study. Compared to the control group of patients (n = 41), patients catheterized with the Multipurpose-SM (n = 43) were shown to have a shorter procedural time as measured by a reduced fluoroscopy time (7.08 min vs. 9.52 min, P = .007). This difference is statistically significant at a 95% confidence level and resulted in less radiation exposure to the operator and cath lab staff. The procedural time was significantly reduced by fewer catheter exchanges (19% study vs. 46% control; P = .006), which were needed to successfully complete the procedure. The new Multipurpose-SM catheter also demonstrated enhanced flexibility for cannulating coronary arteries with superior or anterior takeoffs. This study concludes that the utilization of a modified Multipurpose-SM catheter is safe and effective in cannulating both the left and right coronary arteries, bypass grafts, and performing left ventriculography. The primary benefits of using this modified catheter are reduced fluoroscopy time and the need for fewer catheter exchanges. PMID:7834732

  9. Percutaneous catheter drainage of intraabdominal abscesses and fluid

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Tae; Kwon, Tae Hee; Yoo, Hyung Sik; Suh, Jung Ho [Yonsei University College of Medicine, Seoul (Korea, Republic of); Lee, Young Ho [Cheil General Hospital, Seoul (Korea, Republic of)

    1986-10-15

    Percutaneous catheter drainage has been reported to be an effective method in the management of selected patients with abscess and fluid collection. Its high success rate and relatively low complications make the procedure an alternative to surgery in the individual cases. During past two years percutaneous catheter drainage in 25 patients with intraabdominal abscesses and fluid collection was performed at the Department of Radiology, Yonsei University College of medicine. Here the technique and author's results were summarized. 1. The total 25 patients who had percutaneous catheter drainage are 10 liver abscesses, 3 subphrenic, one subhepatic, 4 renal and perirenal, 2 pelvic, one psoas, one anterior pararenal fluid from acute pancreatitis, one pancreas pseudocyst and 2 malignant tumor necrosis. 2. The modified Seldinger technique used for all cases of abscess and fluid drainage under guidance of ultrasound scan. The used catheters were 10F. Pigtail and 14F. Malecot (Cook c/o) catheters. 3. The abscesses and fluid of 17 patients among 25 were cured by the percutaneous catheter drainage and 4 patients were clinically improved. The catheter drainage was failed in 2 patients and 3 complication were developed. 4. The success rate of this procedure was 91.3%, failure rate was 8.7% and complication rate was 12%.

  10. The pathogenesis and epidemiology of catheter-related infection with pulmonary artery Swan-Ganz catheters: a prospective study utilizing molecular subtyping.

    Science.gov (United States)

    Mermel, L A; McCormick, R D; Springman, S R; Maki, D G

    1991-09-16

    To delineate the pathogenesis and epidemiology of catheter-related infection with Swan-Ganz pulmonary artery (PA) catheters, a prospective clinical study of hospitalized adult medical and surgical patients was done. Role of catheter material was assessed by randomizing insertions to heparin-bonded PA catheters made of polyvinylchloride or polyurethane. Sources of infection and pathogenesis were studied by culturing skin, the introducer, the PA catheter tip, all hubs, infusate from each lumen, and the extravascular portion of the PA catheter beneath the external protective plastic sleeve. Concordance between isolates from sources and infected catheters was determined by speciation, antibiogram, and for coagulase-negative staphylococci, plasmid profile analysis. Risk factors for infection were determined by stepwise logistic regression. Overall, 65 (22%) of 297 Swan-Ganz catheters showed local infection of the introducer (58 catheters) or the intravascular portion of the PA catheter (20 catheters); only two catheters (0.7%) caused bacteremia. Eighty percent of infected Swan-Ganz catheters (the introducer or PA catheter) showed concordance with organisms cultured from skin of the insertion site, 17% with a contaminated hub and 18% with organisms contaminating the extravascular portion of the PA catheter beneath the sleeve. Isolates from infected PA catheters were most likely to show concordance with concomitantly infected introducers (71%). Cutaneous colonization of the insertion site with greater than 10(2) cfu/10 cm2 (relative risk [RR] 5.5; p less than 0.001), insertion into an internal jugular vein (RR 4.3; p less than 0.01), catheterization greater than 3 days (RR 3.1; p less than 0.01), and insertion in the operating room using less stringent barrier precautions (RR 2.1; p = 0.03) were each associated with a significantly increased risk of catheter-related infection. The risk of bacteremic infection with Swan-Ganz catheters is now low, in the range of 1%, with

  11. Hickman catheter embolism in a child during stem cell transplantation

    International Nuclear Information System (INIS)

    The majority of stem cell recipients rely on indwelling central venous catheters situated in superior vena cava or right atrium. Semi-permanent tunneled silicone rubber Hickman catheters are widely used to provide durable central venous access for patients undergoing stem cell transplantation. A case of 5 years old child with diagnosis of severe aplastic anemia is reported. The patient received peripheral blood stem cells (PBSC) and had successful engraftment with complete hematological recovery. He had Hickman catheter embolism in the pulmonary circulation following unsuccessful attempt to remove the line. The catherter was successfully removed by midsternostomy operation. The child is normal with sustained remission on day +218 post stem cell transplant. (author)

  12. Management of catheter-associated upper extremity deep venous thrombosis.

    Science.gov (United States)

    Crawford, Jeffrey D; Liem, Timothy K; Moneta, Gregory L

    2016-07-01

    Central venous catheters or peripherally inserted central catheters are major risk factors for upper extremity deep venous thrombosis (UEDVT). The body and quality of literature evaluating catheter-associated (CA) UEDVT have increased, yet strong evidence on screening, diagnosis, prevention, and optimal treatment is limited. We herein review the current evidence of CA UEDVT that can be applied clinically. Principally, we review the anatomy and definition of CA UEDVT, identification of risk factors, utility of duplex ultrasound as the preferred diagnostic modality, preventive strategies, and an algorithm for management of CA UEDVT. PMID:27318061

  13. Patency of Femoral Tunneled Hemodialysis Catheters and Factors Predictive of Patency Failure

    Energy Technology Data Exchange (ETDEWEB)

    Burton, Kirsteen R. [University Health Network, University of Toronto, Department of Medical Imaging, Division of Vascular and Interventional Radiology (Canada); Guo, Lancia L. Q. [University of Calgary, Department of Radiology (Canada); Tan, Kong T.; Simons, Martin E.; Sniderman, Kenneth W.; Kachura, John R.; Beecroft, John R.; Rajan, Dheeraj K., E-mail: dheeraj.rajan@uhn.on.ca [University Health Network, University of Toronto, Department of Medical Imaging, Division of Vascular and Interventional Radiology (Canada)

    2012-12-15

    Purpose: To determine the patency rates of and factors associated with increased risk of patency failure in patients with femoral vein tunneled hemodialysis catheters. Methods: All femoral tunneled catheter insertions from 1996 to 2006 were reviewed, during which time 123 catheters were inserted. Of these, 66 were exchanges. Patients with femoral catheter failure versus those with femoral catheter patency were compared. Confounding factors, such as demographic and procedural factors, were incorporated and assessed using univariate and multivariable Cox proportional hazards regression analyses. Results: Mean catheter primary patency failure time was 96.3 days (SE 17.9 days). Primary patency at 30, 60, 90, and 180 days was 53.8%, 45.4%, 32.1%, and 27.1% respectively. Crude rates of risk of catheter failure did not suggest a benefit for patients receiving catheters introduced from one side versus the other, but more cephalad location of catheter tip was associated with improved patency. Multivariate analysis showed that patients whose catheters were on the left side (p = 0.009), were of increasing age at the time of insertion (p = 0.002) and that those who had diabetes (p = 0.001) were at significantly greater risk of catheter failure. The catheter infection rate was 1.4/1000 catheter days. Conclusion: Patients who were of a more advanced age and had diabetes were at greater risk of femoral catheter failure, whereas those who received femoral catheters from the right side were less at risk of catheter failure.

  14. Hematologic patients' clinical and psychosocial experiences with implanted long-term central venous catheter

    DEFF Research Database (Denmark)

    Møller, Tom; Adamsen, Lis

    2010-01-01

    A significant decrease in catheter-related infections was demonstrated in our earlier randomized controlled trial of central venous catheter (CVC) care in hematologic patients.......A significant decrease in catheter-related infections was demonstrated in our earlier randomized controlled trial of central venous catheter (CVC) care in hematologic patients....

  15. Patency of Femoral Tunneled Hemodialysis Catheters and Factors Predictive of Patency Failure

    International Nuclear Information System (INIS)

    Purpose: To determine the patency rates of and factors associated with increased risk of patency failure in patients with femoral vein tunneled hemodialysis catheters. Methods: All femoral tunneled catheter insertions from 1996 to 2006 were reviewed, during which time 123 catheters were inserted. Of these, 66 were exchanges. Patients with femoral catheter failure versus those with femoral catheter patency were compared. Confounding factors, such as demographic and procedural factors, were incorporated and assessed using univariate and multivariable Cox proportional hazards regression analyses. Results: Mean catheter primary patency failure time was 96.3 days (SE 17.9 days). Primary patency at 30, 60, 90, and 180 days was 53.8%, 45.4%, 32.1%, and 27.1% respectively. Crude rates of risk of catheter failure did not suggest a benefit for patients receiving catheters introduced from one side versus the other, but more cephalad location of catheter tip was associated with improved patency. Multivariate analysis showed that patients whose catheters were on the left side (p = 0.009), were of increasing age at the time of insertion (p = 0.002) and that those who had diabetes (p = 0.001) were at significantly greater risk of catheter failure. The catheter infection rate was 1.4/1000 catheter days. Conclusion: Patients who were of a more advanced age and had diabetes were at greater risk of femoral catheter failure, whereas those who received femoral catheters from the right side were less at risk of catheter failure.

  16. Accuracy of needle position measurements using fiber Bragg gratings.

    Science.gov (United States)

    Henken, Kirsten; Van Gerwen, Dennis; Dankelman, Jenny; Van Den Dobbelsteen, John

    2012-11-01

    Accurate placement of the needle tip is essential in percutaneous therapies such as radiofrequency ablation (RFA) of liver tumors. Use of a robotic system for navigating the needle could improve the targeting accuracy. Real-time information on the needle tip position is needed, since a needle deflects during insertion in tissue. Needle shape can be reconstructed based on strain measurements within the needle. In the current experiment we determined the accuracy with which the needle tip position can be derived from strain measurements using Fiber Bragg Gratings (FBGs). Three glass fibers equipped with two FBGs each were incorporated in a needle. The needle was clamped at one end and deformed by applying static radial displacements at one or two locations. The FBG output was used for offline estimation of the needle shape and tip position. During deflections of the needle tip up to 12.5 mm, the tip position was estimated with a mean accuracy of 0.89 mm (std 0.42 mm). Adding a second deflection resulted in an error of 1.32 mm (std 0.48 mm). This accuracy is appropriate for applications such as RFA of liver tumors. The results further show that the accuracy can be improved by optimizing the placement of FBGs. PMID:22455615

  17. The research of knitting needle status monitoring setup

    Science.gov (United States)

    Liu, Lu; Liao, Xiao-qing; Zhu, Yong-kang; Yang, Wei; Zhang, Pei; Zhao, Yong-kai; Huang, Hui-jie

    2013-09-01

    In textile production, quality control and testing is the key to ensure the process and improve the efficiency. Defect of the knitting needles is the main factor affecting the quality of the appearance of textiles. Defect detection method based on machine vision and image processing technology is universal. This approach does not effectively identify the defect generated by damaged knitting needles and raise the alarm. We developed a knitting needle status monitoring setup using optical imaging, photoelectric detection and weak signal processing technology to achieve real-time monitoring of weaving needles' position. Depending on the shape of the knitting needle, we designed a kind of Glass Optical Fiber (GOF) light guides with a rectangular port used for transmission of the signal light. To be able to capture the signal of knitting needles accurately, we adopt a optical 4F system which has better imaging quality and simple structure and there is a rectangle image on the focal plane after the system. When a knitting needle passes through position of the rectangle image, the reflected light from needle surface will back to the GOF light guides along the same optical system. According to the intensity of signals, the computer control unit distinguish that the knitting needle is broken or curving. The experimental results show that this system can accurately detect the broken needles and the curving needles on the knitting machine in operating condition.

  18. Preparation of hollow spherical carbon nanocages

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, C.-K.; Kang, H. Y.; Hong, C.-I; Huang, C.-H.; Chang, F.-C.; Wang, H. Paul, E-mail: wanghp@mail.ncku.edu.tw [National Cheng Kung University, Department of Environmental Engineering, Taiwan (China)

    2012-12-15

    This study presents a new and simple method for the synthesis of hollow carbon spheres possessing nanocage sizes of 7.1, 14, and 20 nm in diameter. The core-shell (i.e., Cu-C) nanoparticles prepared by carbonization of the Cu{sup 2+}-cyclodextrin (CD) complexes at 573 K for 2 h was etched with HCl (6N) to yield the hollow carbon spheres. The carbon-shell of the hollow carbon nanospheres, which consisted of mainly diamond-like and graphite carbons, is not perturbed during etching. In addition to the nanocages, the hollow carbon nanospheres also possess micropores with an opening of 0.45 nm, allowing small molecules to diffuse in and out through the carbon-shell. Many elements (such as Zn{sup 2+} or Cu{sup 2+}) can therefore be filled into the nanocages of the hollow carbon nanospheres. With these unique properties, for instance, designable active species such as Cu and ZnO encapsulated in the carbon-shell can act as Cu-ZnO-C yolk-shell nanoreactors which are found very effective in the catalytic decomposition of methanol.

  19. Method for the production of fabricated hollow microspheroids

    Energy Technology Data Exchange (ETDEWEB)

    Wickramanayake, Shan; Luebke, David R.

    2015-06-09

    The method relates to the fabrication of a polymer microspheres comprised of an asymmetric layer surrounding a hollow interior. The fabricated hollow microsphere is generated from a nascent hollow microsphere comprised of an inner core of core fluid surrounded by a dope layer of polymer dope, where the thickness of the dope layer is at least 10% and less than 50% of the diameter of the inner core. The nascent hollow microsphere is exposed to a gaseous environment, generating a vitrified hollow microsphere, which is subsequently immersed in a coagulation bath. Solvent exchange produces a fabricated hollow microsphere comprised of a densified outer skin surrounding a macroporous inner layer, which surrounds a hollow interior. In an embodiment, the polymer is a polyimide or a polyamide-imide, and the non-solvent in the core fluid and the coagulation bath is water. The fabricated hollow microspheres are particularly suited as solvent supports for gas separation processes.

  20. Biologically formed hollow cuprous oxide microspheres

    International Nuclear Information System (INIS)

    Hollow cuprous oxide (Cu2O) microspheres with a diameter of ca. 1.8 μm are prepared by using yeast as template. The possible mechanism for the formation of the hollow Cu2O spheres is revealed. The biotemplated sample is investigated by means of X-ray diffraction (XRD), scanning electron microscopy (SEM) and ultraviolet-visible (UV-vis) absorption spectra. The sample consists of the crystalline Cu2O microspheres with diameters of about 59.5 nm and lattice parameter of 4.264 A. The observed optical band gap of the product indicates that the blue-shift effect occurs, which is attributed to the hollow Cu2O microspheres.

  1. Sheet Plasma Produced by Hollow Cathode Discharge

    Institute of Scientific and Technical Information of China (English)

    张龙; 张厚先; 杨宣宗; 冯春华; 乔宾; 王龙

    2003-01-01

    A sheet plasma is produced by a hollow cathode discharge under an axial magnetic field.The plasma is about 40cm in length,4 cm in width and 1cm in thickness.The electron density is about 108cm-3.The hollow cathode is made to be shallow with a large opening,which is different from the ordinary deep hollow cathode.A Langmuir probe is used to detect the plasma.The electron density and the spatial distribution of the plasma change when voltage,pressure and the magnetic field vary.A peak and a data fluctuation at about 200 G-300 G are observed in the variation of electron density(or thickness of the sheet plasma)with the magnetic field.Our work will be helpful in characterizing the sheet plasma and will make the production of dense sheet plasma more controllable.

  2. Hollow cathode ion source without magnetic field

    International Nuclear Information System (INIS)

    On the base of the IBM-4 ion source a hollow cathode source operating in the continuous regime is developed. The gas discharge chamber diameter equals 100 mm, chamber height - 50 mm. A hollow cathode represents a molybdenum tube with an internal diameter 13 mm and wall thickness 0,7-0,8 mm. An emitter is manufactured from zirconium carbide and lanthanum hexaboride. The investigations of the source operation have shown both cathodes operated efficiency. Electron emission density consitutes 25 A/cm2. At the 50 A discharge current ion current density in a center of plasma emitter constitutes 120 mA/cm2. As a result of the investigations carried out the compatibility of the hollow cathode and the IBM-type source is shown

  3. Sheet plasma produced by hollow cathode discharge

    International Nuclear Information System (INIS)

    A sheet plasma is produced by a hollow cathode discharge under an axial magnetic field. The plasma is about 40 cm in length, 4 cm in width and 1 cm in thickness. The electron density is about 108 cm-3. The hollow cathode is made to be shallow with a large opening, which is different from the ordinary deep hollow cathode. A Langmuir probe is used to detect the plasma. The electron density and the spatial distribution of the plasma change when voltage, pressure and the magnetic field vary. A peak and a data fluctuation at about 200 G - 300 G are observed in the variation of electron density (or thickness of the sheet plasma) with the magnetic field. Our work will be helpful in characterizing the sheet plasma and will make the production of dense sheet plasma more controllable

  4. Needle tip localization using stylet vibration.

    Science.gov (United States)

    Harmat, Adam; Rohling, Robert N; Salcudean, Septimiu E

    2006-09-01

    Power Doppler ultrasound is used to localize the tip of a needle by detecting physical vibrations. Two types of vibrations are investigated, lateral and axial. The lateral vibrations are created by rotating a stylet, whose tip is slightly bent, inside a stationary cannula while the stylet is completely within the cannula. The minute deflection at the needle tip when rotated causes tissue motion. The axial vibration is induced by extending and retracting a straight stylet inside a stationary cannula. The stylet's tip makes contact with the tissue and causes it to move. The lateral vibration method was found to perform approximately the same under a variety of configurations (e.g., different insertion angles and depths) and better than the axial vibration method. Tissue stiffness affects the performance of the lateral vibration method, but good images can be obtained through proper tuning of the ultrasound machine. PMID:16965974

  5. Urinary catheter related nosocomial infections in paediatric intensive care unit.

    Directory of Open Access Journals (Sweden)

    Tullu M

    1998-04-01

    Full Text Available The present prospective study was carried out in the Paediatric Intensive Care Unit (PICU of a tertiary care teaching hospital in Mumbai. The objective was to determine the incidence, risk factors, mortality and organisms responsible for urinary catheter related infections (UCRI. Colonization and/or bacteriuria was labelled as urinary catheter related infection (UCRI. Forty-four patients with 51 urinary catheters were studied. Incidence of UCRI was 47.06%. Age, female sex and immunocompromised status did not increase the risk of UCRI. Duration of catheter in-situ and duration of stay in the PICU were associated with higher risk of UCRI. The mortality was not increased by UCRI. Commonest organism isolated in UCRI was E. coli, which had maximum susceptibility to nitrofurantoin and amikacin.

  6. Suprapubic catheter change resulting in terminal ileal perforation

    Directory of Open Access Journals (Sweden)

    Chih-Peng Chang

    2014-06-01

    Full Text Available Suprapubic cystostomy is commonly performed in patients with neurogenic bladder or bladder outlet obstruction. The most serious complication is bowel injury, which usually occurs during catheter insertion. Bowel perforation during suprapubic catheter exchange is rare. We herein report an extremely rare case of terminal ileal perforation resulting from a change of suprapubic catheter. After insertion of the suprapubic catheter, a feculent material was noted in the terminal ileum. A cystography revealed that the contrast medium passed directly into the terminal ileum and colon. A computed tomographic scan confirmed the presence of a balloon tip in the terminal ileum. Terminal ileum perforation was diagnosed. Emergent laparotomy and loop ileostomy were performed. The patient's recovery was uneventful.

  7. Collateral damage from Catheter Ablation of Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Wanwarang Wongcharoen, MD

    2013-04-01

    Full Text Available Atrial fibrillation (AF is the most common sustained arrhythmia, contributing to a significant morbidity and mortality. Catheter ablation of the pulmonary veins (PVs and left atrium (LA has been shown to be an effective strategy for the treatment of symptomatic AF. Regardless of technological advances and technique improvement, catheter ablation for AF remains a highly complex procedure and the risk of procedural complications is not negligible. The major complications have been reported to occur in up to 5.2% of procedures. A systematic investigation among 32,569 patients undergoing catheter ablation for AF has demonstrated that mortality is around 0.1%. Nevertheless, the true prevalence of complications is possibly underestimated in retrospective surveys because of recollection bias and other factors. This article will focus on the management of serious complications of catheter AF ablation including PV stenosis, atrioesophageal fistula, cardiac tamponade, stroke and thromboembolic complication

  8. FAQs about Catheter-Associated Urinary Tract Infection

    Science.gov (United States)

    ... Tract Infection” What is “catheter-associated urinary tract infection”? A urinary tract infection (also called “UTI”) is an infection in the urinary system, which includes the bladder (which stores the ...

  9. Radiographic signs of non-venous placement of intended central venous catheters in children

    International Nuclear Information System (INIS)

    Central venous catheters (CVCs) are commonly used in children, and inadvertent arterial or extravascular cannulation is rare but has potentially serious complications. To identify the radiographic signs of arterial placement of CVCs. We retrospectively reviewed seven cases of arterially malpositioned CVCs on chest radiograph. These cases were identified through departmental quality-assurance mechanisms and external consultation. Comparison of arterial cases was made with 127 age-matched chest radiographs with CVCs in normal, expected venous location. On each anteroposterior (AP) radiograph we measured the distance of the catheter tip from the right lateral border of the thoracic spine, and the angle of the vertical portion of the catheter relative to the midline. On each lateral radiograph we measured the angle of the vertical portion of each catheter relative to the anterior border of the thoracic spine. When bilateral subclavian catheters were present, the catheter tips were described as crossed, overlapping or uncrossed. On AP radiographs, arterially placed CVCs were more curved to the left, with catheter tip positions located farther to the left of midline than normal venous CVCs. When bilateral, properly placed venous catheters were present, all catheters crossed at the level of the superior vena cava (SVC). When one of the bilateral catheters was in arterial position, neither of the catheters crossed or the inter-catheter crossover distance was exaggerated. On lateral radiographs, there was a marked anterior angulation of the vertical portion of the catheter (mean angle 37 ± 15 standard deviation [SD] in arterial catheters versus 5.9 ± 8.3 SD in normally placed venous catheters). Useful radiographic signs suggestive of unintentional arterial misplacement of vascular catheters include leftward curvature of the vertical portion of the catheter, left-side catheter tip position, lack of catheter crossover on the frontal radiograph, as well as exaggerated

  10. Right atrial indwelling catheter for patients requiring long-term intravenous therapy.

    Science.gov (United States)

    Ivey, M F; Adam, S M; Hickman, R O; Gibson, D L

    1978-12-01

    The use of a central venous catheter for long-term intravenous therapy is described. The catheter's history, physical description, and uses are discussed. Also reviewed are complications from use of the catheter, the pharmacist's role in patient teaching, and the procedure for administering medications through the catheter. A listing of drugs administered through the catheter, incompatibility data and patient teaching instructions are also included. PMID:717409

  11. Number and location of drainage catheter side holes: in vitro evaluation

    International Nuclear Information System (INIS)

    Aim: To evaluate the influence of number and location of catheter shaft side holes regarding drainage efficiency in an in vitro model. Materials and methods: Three different drainage catheter models were constructed: open-ended model with no side holes (one catheter), unilateral side hole model (six catheters with one to six unilateral side holes), and bilateral side hole model (six catheters with one to six bilateral side holes). Catheters were inserted into a drainage output-measuring device with a constant-pressure reservoir of water. The volume of water evacuated by each of the catheters at 10-second intervals was measured. A total of five trials were performed for each catheter. Data were analysed using one-way analysis of variance. Results: The open-ended catheter had a mean drainage volume comparable to the unilateral model catheters with three, four, and five side holes. Unilateral model catheters had significant drainage volume increases up to three side holes; unilateral model catheters with more than three side holes had no significant improvement in drainage volume. All bilateral model catheters had significantly higher mean drainage volumes than their unilateral counterparts. There was no significant difference between the mean drainage volume with one, two, or three pairs of bilateral side holes. Further, there was no drainage improvement by adding additional bilateral side holes. Conclusion: The present in vitro study suggests that beyond a critical side hole number threshold, adding more distal side holes does not improve catheter drainage efficiency. These results may be used to enhance catheter design towards improving their drainage efficiency. -- Highlights: •We evaluated the drainage potential of three different drainage catheter models. •We found adding numerous distal sideholes does not improve catheter drainage. •Bilateral sidehole catheters performed better than unilateral sidehole catheters. •Our in vitro findings may be used to

  12. Radiographic signs of non-venous placement of intended central venous catheters in children

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Erin C. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Taylor, George A. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2016-02-15

    Central venous catheters (CVCs) are commonly used in children, and inadvertent arterial or extravascular cannulation is rare but has potentially serious complications. To identify the radiographic signs of arterial placement of CVCs. We retrospectively reviewed seven cases of arterially malpositioned CVCs on chest radiograph. These cases were identified through departmental quality-assurance mechanisms and external consultation. Comparison of arterial cases was made with 127 age-matched chest radiographs with CVCs in normal, expected venous location. On each anteroposterior (AP) radiograph we measured the distance of the catheter tip from the right lateral border of the thoracic spine, and the angle of the vertical portion of the catheter relative to the midline. On each lateral radiograph we measured the angle of the vertical portion of each catheter relative to the anterior border of the thoracic spine. When bilateral subclavian catheters were present, the catheter tips were described as crossed, overlapping or uncrossed. On AP radiographs, arterially placed CVCs were more curved to the left, with catheter tip positions located farther to the left of midline than normal venous CVCs. When bilateral, properly placed venous catheters were present, all catheters crossed at the level of the superior vena cava (SVC). When one of the bilateral catheters was in arterial position, neither of the catheters crossed or the inter-catheter crossover distance was exaggerated. On lateral radiographs, there was a marked anterior angulation of the vertical portion of the catheter (mean angle 37 ± 15 standard deviation [SD] in arterial catheters versus 5.9 ± 8.3 SD in normally placed venous catheters). Useful radiographic signs suggestive of unintentional arterial misplacement of vascular catheters include leftward curvature of the vertical portion of the catheter, left-side catheter tip position, lack of catheter crossover on the frontal radiograph, as well as exaggerated

  13. Adiabatic Rearrangement of Hollow PV Towers

    Directory of Open Access Journals (Sweden)

    Eric A Hendricks

    2010-10-01

    Full Text Available Diabatic heating from deep moist convection in the hurricane eyewall produces a towering annular structure of elevated potential vorticity (PV. This structure has been referred to as a hollow PV tower. The sign reversal of the radial gradient of PV satisfies the Charney-Stern necessary condition for combined barotropic-baroclinic instability. For thin enough annular structures, small perturbations grow exponentially, extract energy from the mean flow, and lead to hollow tower breakdown, with significant vortex structural and intensity change. The three-dimensional adiabatic rearrangements of two prototypical hurricane-like hollow PV towers (one thick and one thin are examined in an idealized framework. For both hollow towers, dynamic instability causes air parcels with high PV to be mixed into the eye preferentially at lower levels, where unstable PV wave growth rates are the largest. Little or no mixing is found to occur at upper levels. The mixing at lower and middle levels is most rapid for the breakdown of the thin hollow tower, consistent with previous barotropic results. For both hollow towers, this advective rearrangement of PV affects the tropical cyclone structure and intensity in a number of ways. First, the minimum central pressure and maximum azimuthal mean velocity simultaneously decrease, consistent with previous barotropic results. Secondly, isosurfaces of absolute angular momentum preferentially shift inward at low levels, implying an adiabatic mechanism by which hurricane eyewall tilt can form. Thirdly, a PV bridge, similar to that previously found in full-physics hurricane simulations, develops as a result of mixing at the isentropic levels where unstable PV waves grow most rapidly. Finally, the balanced mass field resulting from the PV rearrangement is warmer in the eye between 900 and 700 hPa. The location of this warming is consistent with observed warm anomalies in the eye, indicating that in certain instances the hurricane

  14. Fine Needle Aspiration Cytology of Parathyroid Lesions

    OpenAIRE

    Heo, Ilyeong; Park, Sunhoo; Jung, Chang Won; Koh, Jae Soo; Lee, Seung-Sook; Seol, Hyesil; Choi, Hee Seung; Cho, Soo Youn

    2013-01-01

    Background There has been an increase in the use of fine needle aspiration cytology (FNAC) for the diagnosis of parathyroid lesions (PLs). Differentiation between a thyroid lesion and a PL is not easy because of their similar features. We reviewed parathyroid aspirates in our institution and aimed to uncover trends in diagnostic criteria. Methods We selected 25 parathyroid aspirates (from 6 men and 19 women) confirmed surgically or immunohistochemically from 2006 to 2011. Results Major archit...

  15. CT Guided Needle Biopsies in Pulmonary Nodules

    Directory of Open Access Journals (Sweden)

    Nargess Afzali

    2011-05-01

    Full Text Available determine the prevalence of pulmonary pathologies"nby CT-guided needle biopsy in pulmonary nodules."nPatients and Methods: We performed CT guided"nneedle biopsy on 78 cases of pulmonary nodules. Lung"nCT scan with a 64-Slice MSCT was done for all patients"nbefore the needle biopsy. All biopsies were performed"nby one experienced interventional radiologist by"nusing a semiautomatic coaxial 18 guage needle. The"nresults were confirmed by two pathologists who were"nunaware of each other's reports. Because of different"npathologic diagnosis two cases were excluded from the"nstudy."nResults: The study population included 43 men and"n33 women with the mean age of 62 years. The mean"nlesion diameter was 22 mm (±7 mm. Thirty-nine"ncases were diagnosed as malignant lesions. Benign"npulmonary conditions were diagnosed in 37 patients."nThe most common malignant lesion was pulmonary"nadenocarcinoma (26%, squamous cell carcinoma"nand bronchoalveolar carcinoma were the next ones."nPulmonary metastasis was seen in three cases and non"nHodgkin lymphoma in three patients. The prevalence"nof adenocarcinoma was not significantly different"nbetween men and women (p value=0.01. The mean age"nof the patients with malignant lesions was 74 years and"n56 years in the others. The difference was significant"n(p=0.05. Tuberculosis was the most common cause of"nbenign lesions (14.4% of all cases, intersitial fibrosis"nand anthracosis were the next most common."nConclusion: Most pulmonary nodules were malignant"nand pulmonary adenocarcinoma was the most"nfrequent. Among benign lesions tuberculosis was the"nmost common."nKeywords: Pulmonary Nodules, Needle Biopsy, CT"nGuide

  16. A retractable barb needle for drug darts

    Directory of Open Access Journals (Sweden)

    G.L. van Rooyen

    1973-07-01

    Full Text Available The mechanism and action of a new retractable barbneedle for drug darts are described. This dart needle is particularly successful in obviating unnecessary flight reactions andtrauma in darted animals, and facilitates the complete injection of the drug dose before the barb is retracted and the dart is dislogded from the animal. The whole process is completed within a few seconds and the expended dart can usually be retrieved in the immediate vicinity where the animal was darted.

  17. Pulmonary actinomycosis in fine needle aspiration cytology

    OpenAIRE

    Patel Keyuri; Gupta Gurudutt; Shah Menka; Patel Purvesh

    2009-01-01

    Pulmonary actinomycosis is a rare bacterial lung disease caused by one of two types of bacteria, Actinomyces or Propioni. Pulmonary actinomycosis in the lung causes lung cavities, lung nodules, and pleural effusion. We report here a case of pulmonary actinomycosis that was diagnosed by fine needle aspiration cytology (FNAC). A 45 year-old male with a history of smoking and alcohol abuse, presented with complaints of cough with hemoptysis, right-sided chest pain, and fever of two months′...

  18. Penile gangrene following condom catheter urinary drainage : A case report

    OpenAIRE

    Sandhya Gupta; Vinod Tamaknand; Amit Dangi; Bhawan Nangarwal; Rajesh Godara; Pradeep Garg

    2016-01-01

    External urine collecting devices have been a boon to patients of urinary incontinence since their invention in late 90s. They have replaced the need for uncomfortable indwelling catheters in these patients. As safe as they may be, ghastly complications have occurred infrequently, mostly due to their inappropriate application. Such penile and urethral complications add to the morbidity of the patients significantly. They can be easily avoided by following few simple steps of catheter care, th...

  19. Periinterventional prophylactic antibiotics in radiological port catheter implantation

    International Nuclear Information System (INIS)

    Purpose: To evaluate whether catheter-related infections after radiologically placed port catheters can be reduced by single-shot periinterventional antibiosis. Materials and Method: Between January and September 2002, 164 consecutive patients with indication for central venous port catheter implantation were included in the present study. During implantation the interventional radiologist was responsible for deciding whether to administer a prophylactic single-shot antibiosis. The prophylactic antibiosis entailed intravenous administration of ampicillin and sulbactam (3 g Unacid, Pfizer) or 100 mg ciprofloxacine (Ciprobay, Bayer) in the case of an allergy history to penicillins. Catheter-related infection was defined as a local or systemic infection necessitating port catheter extraction. Results: Indication for port catheter implantation was a malignant disease requiring chemotherapy in 158 cases. The port catheter (Chemosite [Tyco Healthcare] [n = 123], low-profile [Arrow International] [n = 35], other port system [n = 6]) was implanted via sonographically guided puncture of the right jugular vein in 139 patients, via the left jugular vein in 24 cases and via the right subclavian vein in one patient. 75 patients received periinterventional prophylactic antibiosis (Unacid [n = 63] Ciprobay [n 12]) and 89 patients did not receive antibiosis. The prophylactic antibiosis caused a minor allergic reaction in one patient that improved with antihistamic and corticoid medication. A total of 7 ports, 6 without prophylactic antibiosis versus one with periinterventional prophylaxis, were extracted due to infectious complications. Conclusion: Single-shot periinterventional prophylactic antibiosis can reduce early and late infectious complications after radiological-interventional placement of central venous port catheters. (orig.)

  20. Catheter Migration of a Port-a-Cath System

    International Nuclear Information System (INIS)

    A patient with axillary venous thrombosis caused by lymph node compression and the presence of a displaced catheter in the vascular lumen is presented. In this case, percutaneous interventional radiological procedures (balloon angioplasty and snare loop method) in conjunction with medical treatment were effective in limiting the post-thrombotic syndrome and restoring the proper positioning of the catheter, thereby saving the central venous access

  1. Pneumothorax as a complication of central venous catheter insertion

    OpenAIRE

    Tsotsolis, Nikolaos; Tsirgogianni, Katerina; Kioumis, Ioannis; Pitsiou, Georgia; Baka, Sofia; Papaiwannou, Antonis; Karavergou, Anastasia; Rapti, Aggeliki; Trakada, Georgia; Katsikogiannis, Nikolaos; Tsakiridis, Kosmas; Karapantzos, Ilias; Karapantzou, Chrysanthi; Barbetakis, Nikos; Zissimopoulos, Athanasios

    2015-01-01

    The central venous catheter (CVC) is a catheter placed into a large vein in the neck [internal jugular vein (IJV)], chest (subclavian vein or axillary vein) or groin (femoral vein). There are several situations that require the insertion of a CVC mainly to administer medications or fluids, obtain blood tests (specifically the “central venous oxygen saturation”), and measure central venous pressure. CVC usually remain in place for a longer period of time than other venous access devices. There...

  2. Imaging and management of complications of central venous catheters

    International Nuclear Information System (INIS)

    Central venous catheters (CVCs) provide valuable vascular access. Complications associated with the insertion and maintenance of CVCs includes pneumothorax, arterial puncture, arrhythmias, line fracture, malposition, migration, infection, thrombosis, and fibrin sheath formation. Image-guided CVC placement is now standard practice and reduces the risk of complications compared to the blind landmark insertion technique. This review demonstrates the imaging of a range of complications associated with CVCs and discusses their management with catheter salvage techniques

  3. Clinical Practice Guidelines for Vascular Catheter Infections Treatment.

    Directory of Open Access Journals (Sweden)

    Belkys Rodríguez Llerena

    2009-03-01

    Full Text Available Clinical Practice Guidelines for Vascular Catheter Infections Treatment. It has been defined as the presence of local or systemic signs without other obvious infection site, plus the microbiologic evidence involving the catheter. This document includes a review and update of concepts, main clinical aspects, and treatment and stresses the importance of prophylactic treatment. It includes assessment guidelines focused on the most important aspects to be accomplished.

  4. Clinical Practice Guidelines for Vascular Catheter Infections Treatment.

    OpenAIRE

    Belkys Rodríguez Llerena.; Marcos Diosdado Iraola Ferrer

    2009-01-01

    Clinical Practice Guidelines for Vascular Catheter Infections Treatment. It has been defined as the presence of local or systemic signs without other obvious infection site, plus the microbiologic evidence involving the catheter. This document includes a review and update of concepts, main clinical aspects, and treatment and stresses the importance of prophylactic treatment. It includes assessment guidelines focused on the most important aspects to be accomplished.

  5. Urinary catheter with polyurethane coating modified by ion implantation

    International Nuclear Information System (INIS)

    A low friction urinary catheter that could be used without a lubricant is proposed in this work. A polyurethane coating was synthesised on the surface of a metal guide wire catheter. Ion implantation was applied to surface modify the polyurethane coating. FTIR ATR, wetting angle, AFM and friction tests were used for analysis. Low friction was found to be provided by the formation of a hard carbonised layer on the polyurethane surface

  6. Detection of endotoxin on sterile catheters used for cardiac catheterization.

    OpenAIRE

    Kundsin, R B; Walter, C. W.

    1980-01-01

    Pyrogen reactions during cardiac catheterization are an alarming complication that frightens patients and baffles many physicans. This report describes a simple, reproducible, precise technique for the measurement of endotoxin-like activity on the inner and outer surfaces of catheters intended for intravascular insertion. This technique is useful in documenting the cause of patient reactions. Quality control procedures should be instituted following the manufacture of angiographic catheters s...

  7. Asystole during pulmonary artery catheter insertion under general anesthesia

    Directory of Open Access Journals (Sweden)

    Swapna Chaudhuri

    2012-01-01

    Full Text Available In spite of ongoing debate for the past 40 years, pulmonary artery catheters remain in use for invasive hemodynamic monitoring and management of critically ill patients. We describe a case of a sudden onset of asystolic cardiac arrest during the placement of a pulmonary artery catheter, while under general anesthesia. A brief review of the literature highlighting arrhythmic complications associated with pulmonary artery catheterization is also presented.

  8. Strong guiding of light in hollow nanowire Structures

    Institute of Scientific and Technical Information of China (English)

    Liang Chen; James De Leon; Xiaomin Jin

    2007-01-01

    @@ We have theoretically investigated the guiding mode patterns of hollow nanowires. Two types of nanowires,round shape and hexagonal shape, are examined with different combination of outer and inner radii.Because of electric field discontinuity at hollow interfaces and evanescent modes overlap in low refractive index region, strong light guiding and confinement are achieved in both hollow wire structures.

  9. Generation of a hollow laser beam by a multimode fiber

    Institute of Scientific and Technical Information of China (English)

    Hongyu Ma; Huadong Cheng; Wenzhuo Zhang; Liang Liu; Yuzhu Wang

    2007-01-01

    A simple method to generate a hollow laser beam by multimode fiber is reported. A dark hollow laser beam is generated from a multimode fiber and the dependence of the output beam profile on the incident angle of laser beam is analyzed. The results show that this hollow laser beam can be used to trap and guide cold atoms.

  10. Plastic Hollow Tubes As Waveguides For IR Radiation

    Science.gov (United States)

    Croitoru, N.; Dror, J.; Mendlovic, D.

    1988-06-01

    A theoretical ray model was developed for energy distribution of IR radiation, transmitted through hollow straight and bent fibers. The theoretical results were compared with the experimental data obtained from measurements of our plastic hollow fibers. A satisfactory agreement between the experimental and theoretical data was achieved. Application of the plastic hollow fibers in surgery (on certain organic tissues) is described.

  11. Development of Magnetic Hollow Cold Cathode for Ion Source

    OpenAIRE

    Djamel Boubetra; Bouafia, M.

    2008-01-01

    The research presented in this study focuses on the development of ion source with hollow cold cathodes which supplies low-power and high ion-current density applications. The theoretical and experimental results were used to design a second-generation laboratory model, low-current hollow cathode. Present experiment is to design a hollow cold cathode with two application possibilities.

  12. Exploration of New Electroacupuncture Needle Material

    Directory of Open Access Journals (Sweden)

    Sanghun Lee

    2012-01-01

    Full Text Available Background. Electro Acupuncture (EA uses the acupuncture needle as an electrode to apply low-frequency stimulation. For its safe operation, it is essential to prevent any corrosion of the acupuncture needle. Objective. The aim of this study is to find an available material and determine the possibility of producing a standard EA needle that is biocompatible. Methods. Biocompatibility was tested by an MTT assay and cytotoxicity testing. Corrosion was observed with a scanning electron microscope (SEM after 0.5 mA, 60 min stimulation. The straightness was measured using a gap length of 100 mm, and tensile testing was performed by imposing a maximum tensile load. Results. Phosphor bronze, Ni coated SS304, were deemed inappropriate materials because of mild-to-moderate cytotoxicity and corrosion. Ti-6Al-4V and SS316 showed no cytotoxicity or corrosion. Ti-6Al-4V has a 70 times higher cost and 2.5 times lower conductivity than SS316. The results of both straightness and tensile testing confirmed that SS316 can be manufactured as a standard product. Conclusion. As a result, we confirmed that SS316 can be used a new EA electrode material. We hope that a further study of the maximum capacity of low-frequency stimulation using an SS316 for safe operation.

  13. Exploration of new electroacupuncture needle material.

    Science.gov (United States)

    Lee, Sanghun; Choi, Gwang-Ho; Lee, Chang Hoon; Kim, Yu Kyoung; Lee, Saebhom; Cho, Sungjin; Yeon, Sunhee; Choi, Sun-Mi; Ryu, Yeon-Hee

    2012-01-01

    Background. Electro Acupuncture (EA) uses the acupuncture needle as an electrode to apply low-frequency stimulation. For its safe operation, it is essential to prevent any corrosion of the acupuncture needle. Objective. The aim of this study is to find an available material and determine the possibility of producing a standard EA needle that is biocompatible. Methods. Biocompatibility was tested by an MTT assay and cytotoxicity testing. Corrosion was observed with a scanning electron microscope (SEM) after 0.5 mA, 60 min stimulation. The straightness was measured using a gap length of 100 mm, and tensile testing was performed by imposing a maximum tensile load. Results. Phosphor bronze, Ni coated SS304, were deemed inappropriate materials because of mild-to-moderate cytotoxicity and corrosion. Ti-6Al-4V and SS316 showed no cytotoxicity or corrosion. Ti-6Al-4V has a 70 times higher cost and 2.5 times lower conductivity than SS316. The results of both straightness and tensile testing confirmed that SS316 can be manufactured as a standard product. Conclusion. As a result, we confirmed that SS316 can be used a new EA electrode material. We hope that a further study of the maximum capacity of low-frequency stimulation using an SS316 for safe operation. PMID:22675386

  14. Scaffold Characteristics for Functional Hollow Organ Regeneration

    Directory of Open Access Journals (Sweden)

    Daniel Eberli

    2010-01-01

    Full Text Available Many medical conditions require surgical reconstruction of hollow organs. Tissue engineering of organs and tissues is a promising new technique without harvest site morbidity. An ideal biomaterial should be biocompatible, support tissue formation and provide adequate structural support. It should degrade gradually and provide an environment allowing for cell-cell interaction, adhesion, proliferation, migration, and differentiation. Although tissue formation is feasible, functionality has never been demonstrated. Mainly the lack of proper innervation and vascularisation are hindering contractility and normal function. In this chapter we critically review the current state of engineering hollow organs with a special focus on innervation and vascularisation.

  15. Continuous shoulder analgesia via an indwelling axillary brachial plexus catheter.

    Science.gov (United States)

    Reuben, S S; Steinberg, R B

    2000-09-01

    Continuous interscalene brachial plexus blockade can provide anesthesia and analgesia in the shoulder region. Difficulty accessing the interscalene space and premature displacement of interscalene catheters may preclude their use in certain situations. We present two case reports in which a catheter was advanced from the axilla along the brachial plexus sheath to the interscalene space to provide continuous cervicobrachial plexus analgesia. In the first case report, previous neck surgery made the anatomic landmarks for performing an interscalene block very difficult. An epidural catheter was advanced from the axillary brachial plexus sheath to the interscalene space under fluoroscopic guidance. This technique provided both intraoperative analgesia for shoulder surgery as well as 24-hour postoperative analgesia by an infusion of 0.125% bupivacaine. In the second case report, a catheter was inserted in a similar fashion from the axillary to the interscalene space to provide 14 days of continuous analgesia in the management of complex regional pain syndrome. We have found that this technique allows us to secure the catheter more easily than with the traditional interscalene approach and thus prevents premature dislodgment. This approach may be a suitable alternative when either an interscalene or an infraclavicular catheter may not be inserted. PMID:11090734

  16. Important aspects of the colonization of central venous catheter.

    Science.gov (United States)

    Andreoli-Pinto, T J; Graziano, K U

    1999-01-01

    This study comprises five different kind of venous central catheters, 103 in total, made of Polyurethane Tecoflex, Polyurethane Vialon, PTFE and PVC, and the influence of their raw material on the microbial colonization. Patients age and sex, besides their clinical conditions, were taken into account, and neither considered as a sample vicious, nor associated with colonization. When the tips of the catheters were asseptically inoculated in Tryptic Soy Broth and Tioglicolate, colonization was detected in 15.5% of the catheters. Coagulase negative Staphylococcus, some of which with biofilm, were the predominant organisms found, although some bacillus have also been detected: Enterobacter aerogenes, Hafnia alvei, Pseudomonas cepacia, Xanthomonas maltophilia and Aeromonas sobria. It was not possible to notice any association between the colonization of the catheters and their raw material, probably due to the influence of a previous contact and linking with blood components. This contact causes a thin coating on the surface of the cathether, which makes all the catheters similar in respect of the attachment of a bacterial cell. So, the colonization depends on the virulence of the organism, much more then on the nature of the catheter. PMID:10326311

  17. Contact force assessment in catheter ablation of atrial fibrillatio

    Directory of Open Access Journals (Sweden)

    Josef Kautzner; Petr Peichl

    2014-04-01

    Full Text Available The efficacy of catheter ablation of atrial fibrillation (AF remains limited. Increase of success would require more durable lesions without increased risk of steam pop and cardiac perforation. Recently, novel technologies have been developed to estimate real-time catheter-tissue contact force (CF. This paper reviews three available tools for assessment of CF and data on experimental or clinical experience. Experimental data with open-irrigated catheter showed that lesion size was greater with applications of lower power (like 30 W and greater CF (e.g. 30 to 40 g than vice versa. Impedance drop in the first 5 seconds was significantly correlated to catheter CF. Perforation was achieved more rapidly with the ablation catheter in a sheath despite the same CF because the sheath prevents catheter buckling. Clinical experience confirmed poor relationship between CF and either unipolar amplitude, bipolar amplitude, or impedance. Within the left atrium, the most common high CF site was found at the anterior/rightward LA roof, directly beneath the ascending aorta (confirmed by merging the CT image and map. Importantly, several studies showed that the use of CF leads to shorter procedure with less fluoroscopy time and less RF applications. CF assessment was also found to be associated with higher proportion of durable lesions. Finally, pilot studies showed that CF measurement could be associated with better clinical efficacy AF ablation.

  18. Bacterial biofilms in patients with indwelling urinary catheters.

    Science.gov (United States)

    Stickler, David J

    2008-11-01

    Bacteria have a basic survival strategy: to colonize surfaces and grow as biofilm communities embedded in a gel-like polysaccharide matrix. The catheterized urinary tract provides ideal conditions for the development of enormous biofilm populations. Many bacterial species colonize indwelling catheters as biofilms, inducing complications in patients' care. The most troublesome complications are the crystalline biofilms that can occlude the catheter lumen and trigger episodes of pyelonephritis and septicemia. The crystalline biofilms result from infection by urease-producing bacteria, particularly Proteus mirabilis. Urease raises the urinary pH and drives the formation of calcium phosphate and magnesium phosphate crystals in the biofilm. All types of catheter are vulnerable to encrustation by these biofilms, and clinical prevention strategies are clearly needed, as bacteria growing in the biofilm mode are resistant to antibiotics. Evidence indicates that treatment of symptomatic, catheter-associated urinary tract infection is more effective if biofilm-laden catheters are changed before antibiotic treatment is initiated. Infection with P. mirabilis exposes the many faults of currently available catheters, and plenty of scope exists for improvement in both their design and production; manufacturers should take up the challenge to improve patient outcomes. PMID:18852707

  19. Peripherally Inserted Central Catheters Complicated by Vascular Erosion in Neonates.

    Science.gov (United States)

    Blackwood, Brian P; Farrow, Kathryn N; Kim, Stan; Hunter, Catherine J

    2016-08-01

    Peripherally inserted central catheters (PICCs) are widely used in the pediatric population, and their use continues to grow in popularity. These catheters provide a reliable source of venous access to neonatal patients but can also be the cause of life-threatening complications. There are several well-documented complications such as infections, catheter thrombosis, vascular extravasations, and fractured catheters. However, the complication of vascular erosion into the pleural space using both small and silicone-based catheters is rarely described. After obtaining institutional review board approval, we identified 4 cases to review of PICCs complicated by vascular erosions in the past 2 years. Herein, we also review the current literature of PICC complications. Getting the catheter tip as close to the atrial-caval junction as possible and confirmation of this placement are of the utmost importance. The thick wall of the vena cava near the atrium seems to be less likely to perforate; in addition, this position provides increased volume and turbulence to help dilute the hyperosmolar fluid, which seems to also be a factor in this complication. A daily screening chest x-ray in patients with upper extremity PICCs and ongoing parenteral nutrition (PN) are not necessary at this time given the overall low rate of vascular erosion and concerns regarding excessive radiation exposure in pediatric populations. However, a low threshold for chest x-ray imaging in patients with even mild respiratory symptoms in the setting of upper extremity PN is recommended. PMID:25700180

  20. Ultrasound-guided robot for flexible needle steering.

    Science.gov (United States)

    Neubach, Zipi; Shoham, Moshe

    2010-04-01

    The success rate of medical procedures involving needle insertion is often directly related to needle placement accuracy. Due to inherent limitations of commonly used freehand needle placement techniques, there is a need for a system providing for controlled needle steering for procedures that demand high positional accuracy. This paper describes a robotic system developed for flexible needle steering inside soft tissues under real-time ultrasound imaging. An inverse kinematics algorithm based on a virtual spring model is applied to calculate needle base manipulations required for the tip to follow a curved trajectory while avoiding physiological obstacles. The needle tip position is derived from ultrasound images and is used in calculations to minimize the tracking error, enabling a closed-loop needle insertion. In addition, as tissue stiffness is a necessary input to the control algorithm, a novel method to classify tissue stiffness from localized tissue displacements is proposed and shown to successfully distinguish between soft and stiff tissue. The system performance was experimentally verified by robotic manipulation of the needle base inside a phantom with layers of varying stiffnesses. The closed-loop experiment with updated tissue stiffness parameters demonstrated a needle-tip tracking error of approximately 1 mm and proved to be significantly more accurate than the freehand method. PMID:19709957

  1. Gastroretentive delivery systems: hollow beads.

    Science.gov (United States)

    Talukder, R; Fassihi, R

    2004-04-01

    The objective of this study was to develop a floatable multiparticulate system with potential for intragastric sustained drug delivery. Cross-linked beads were made by using calcium and low methoxylated pectin (LMP), which is an anionic polysaccharide, and calcium, LMP, and sodium alginate. Beads were dried separately in an air convection type oven at 40 degrees C for 6 hours and in a freeze dryer to evaluate the changes in bead characteristics due to process variability. Riboflavin (B-2), tetracycline (TCN), and Methotrexate (MTX) were used as model drugs for encapsulation. Ionic and nonionic excipients were added to study their effects on the release profiles of the beads. The presence of noncross linking agents in low amounts (less than 2%) did not significantly interfere with release kinetics. For an amphoteric drug like TCN, which has pH dependent solubility, three different pHs (1.5, 5.0, and 8.0) of cross-linking media were used to evaluate the effects of pH on the drug entrapment capacity of the beads. As anticipated, highest entrapment was possible when cross-linking media pH coincided with least drug solubility. Evaluation of the drying process demonstrated that the freeze-dried beads remained buoyant over 12 hours in United States Pharmacopeia (USP) hydrochloride buffer at pH 1.5, whereas the air-dried beads remained submerged throughout the release study. Confocal laser microscopy revealed the presence of air-filled hollow spaces inside the freeze dried beads, which was responsible for the flotation property of the beads. However, the release kinetics from freeze dried beads was independent of hydrodynamic conditions. Calcium-pectinate-alginate beads released their contents at much faster rates than did calcium-pectinate beads (100% in 10 hours vs. 50% in 10 hours). It appears that the nature of cross-linking, drying method, drug solubility, and production approach are all important and provide the opportunity and potential for development of a

  2. The effects of needle deformation during lumbar puncture

    Directory of Open Access Journals (Sweden)

    Hasan Hüseyin Özdemir

    2015-01-01

    Full Text Available Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP. Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1% of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3% of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%. Forty-seven (41.5% patients experienced post lumbar puncture headache (PLPH and 13 (11.5% patients experienced intracranial hypotension (IH. No statistically significant correlation between the degree of deflection and headache was found (P > 0.05. Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH.

  3. The effects of needle deformation during lumbar puncture

    Science.gov (United States)

    Özdemir, Hasan Hüseyin; Demir, Caner F.; Varol, Sefer; Arslan, Demet; Yıldız, Mustafa; Akil, Eşref

    2015-01-01

    Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP). Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1%) of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3%) of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%). Forty-seven (41.5%) patients experienced post lumbar puncture headache (PLPH) and 13 (11.5%) patients experienced intracranial hypotension (IH). No statistically significant correlation between the degree of deflection and headache was found (P > 0.05). Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH. PMID:25883480

  4. Fast integrated intravascular photoacoustic/ultrasound catheter

    Science.gov (United States)

    Choi, Changhoon; Cho, Seunghee; Kim, Taehoon; Park, Sungjo; Park, Hyoeun; Kim, Jinmoo; Lee, Seunghoon; Kang, Yeonsu; Jang, Kiyuk; Kim, Chulhong

    2016-03-01

    In cardiology, a vulnerable plaque is considered to be a key subject because it is strongly related to atherosclerosis and acute myocardial infarction. Because conventional intravascular imaging devices exhibit several limitations with regard to vulnerable plaque detection, the need for an effective lipid imaging modality has been continuously suggested. Photoacoustic (PA) imaging is a medical imaging technique with a high level of ultrasound (US) resolution and strong optical contrast. In this study, we successfully developed an integrated intravascular photoacoustic/ultrasound (IV-PAUS) imaging system with a catheter diameter of 1.2 mm for lipid-rich atherosclerosis imaging. An Nd:YAG pulsed laser with an excitation wavelength of 1064 nm was utilized. IV-PAUS offers 5-mm depth penetration and axial and lateral PA imaging resolutions of 94 μm and 203 μm, respectively, as determined by imaging a 6-μm carbon fiber. We initially obtained 3-dimensional (3D) co-registered PA/US images of metal stents. Subsequently, we successfully obtained 3D coregistered PA/US ex vivo images using an iliac artery from a rabbit atherosclerosis model. Accordingly, lipid-rich plaques were sufficiently differentiated from normal tissue in the ex vivo experiment. We validated these findings histologically to confirm the lipid content.

  5. Balloon catheter dilatation of benign urethral strictures

    International Nuclear Information System (INIS)

    The authors report their experience of benign urethral stricture dilatation by balloon catheter in 11 male patients. Ten posterior and 2 anterior urethral strictures were treated; in 1 patients several narrowings coexisted at various levels. Etiology was inflammatory in 4 cases, iatrogen in 3, post-traumatic in 2, and equivocal in 2. The patients were studied both before and soon after dilatation by means of retrograde and voiding cystourethrogram and uroflowgraphy; the follow-up (2-14 months) was performed by urodynamic alone. In all cases, dilatation was followed by the restoration of urethral gauge, together with prompt functional improvement of urodynamic parameters. The latter result subsisted in time in 9 patients. In 2 cases recurrences were observed demonstrated at once by clinics and urodynamics. Both lesions were successfully re-treated. Neither early not late complication occurred. In spite of the limited material, the valuable results obtained, together with the absence of complications, the peculiar morphology of recurrences, and the chance of repeating it make the procedure advisable as a valid alternative to conventional techniques for these pathologies

  6. Bacterial Biofilms and Catheters: A Key to Understanding Bacterial Strategies in Catheter-Associated Urinary Tract Infection

    OpenAIRE

    Nickel, J. Curtis; Costerton, J. William

    1992-01-01

    Despite major technological improvements in catheter drainage systems, the indwelling Foley catheter remains the most common cause of nosocomial infection in medical practice. By approaching this common complicated urinary tract infection from the perspective of the biofilm strategy bacteria appear to use to overcome obstacles to produce bacteriuria, one appreciates a new understanding of these infections. An adherent biofilm of bacteria in their secretory products ascends the luminal and ext...

  7. Fabrication of AlN/BN bishell hollow nanofibers by electrospinning and atomic layer deposition

    Directory of Open Access Journals (Sweden)

    Ali Haider

    2014-09-01

    Full Text Available Aluminum nitride (AlN/boron nitride (BN bishell hollow nanofibers (HNFs have been fabricated by successive atomic layer deposition (ALD of AlN and sequential chemical vapor deposition (CVD of BN on electrospun polymeric nanofibrous template. A four-step fabrication process was utilized: (i fabrication of polymeric (nylon 6,6 nanofibers via electrospinning, (ii hollow cathode plasma-assisted ALD of AlN at 100 °C onto electrospun polymeric nanofibers, (iii calcination at 500 °C for 2 h in order to remove the polymeric template, and (iv sequential CVD growth of BN at 450 °C. AlN/BN HNFs have been characterized for their chemical composition, surface morphology, crystal structure, and internal nanostructure using X-ray photoelectron spectroscopy, scanning electron microscopy, transmission electron microscopy, energy dispersive X-ray spectroscopy, and selected area electron diffraction. Measurements confirmed the presence of crystalline hexagonal BN and AlN within the three dimensional (3D network of bishell HNFs with relatively low impurity content. In contrast to the smooth surface of the inner AlN layer, outer BN coating showed a highly rough 3D morphology in the form of BN nano-needle crystallites. It is shown that the combination of electrospinning and plasma-assisted low-temperature ALD/CVD can produce highly controlled multi-layered bishell nitride ceramic hollow nanostructures. While electrospinning enables easy fabrication of nanofibrous template, self-limiting reactions of plasma-assisted ALD and sequential CVD provide control over the wall thicknesses of AlN and BN layers with sub-nanometer accuracy.

  8. Gamma radiation-sterilized, triple-lumen catheters coated with a low concentration of chlorhexidine were not efficacious at preventing catheter infections in intensive care unit patients.

    OpenAIRE

    Sherertz, R J; Heard, S O; Raad, I I; Gentry, L; Bowton, D; Scuderi, P; Hu, J.; Carruth, W; Satishchandra, B; J. Pepe; Mosenthal, A; Burke, T.; Dupuis, J.

    1996-01-01

    In a randomized, double-blind trial, gamma radiation-sterilized, chlorhexidine-coated triple-lumen catheters were compared with uncoated control catheters for their ability to prevent catheter infection in 254 intensive care unit patients. The chlorhexidine coating was not efficacious, and a rabbit model demonstrated that reduction of chlorhexidine activity by gamma radiation sterilization was the likely explanation for the failure.

  9. Potential In Vivo UVC Disinfection of Catheter Lumens: Estimation of the Doses Received by the Blood Flow Outside the Catheter Tip Hole

    DEFF Research Database (Denmark)

    Bak, Jimmy; Jørgensen, Thomas Martini; Helfmann, Jurgen;

    2011-01-01

    We have demonstrated that it is possible to launch UVC LED light into bacterial contaminated polymer tubes/catheters and disinfect the intraluminal space of these tubes. This can be achieved by UVC treatment of the catheters on a regular basis. Catheters are in the distal end equipped with an exi...

  10. Hollow circular-truncated cone resonator and its hollow variable biconical laser beam

    Science.gov (United States)

    Liu, Jinglun; Chen, Mei; Wang, Qionghua; Sun, Nianchun

    2014-05-01

    To obtain a hollow variable biconical laser beam (HVBLB), a CO2 laser having a hollow circular-truncated cone resonator (HCTCR) is presented. This HCTCR comprises a rotationally symmetric total-reflecting concave mirror at the bottom, a rotationally symmetric part-reflecting convex mirror at the top, and a hollow circular-truncated cone discharge tube at the middle. The cross section of this generated biconical laser beam changes from annulus to circular to annulus and the size of this cross section from big to small to large as the propagation distance increases. So, a kind of laser beam with variable center intensity from zero to peak value to zero is obtained and is known as HVBLB. Due to the inclusion of part of the hollow laser beam (HLB) and solid laser beam, this HVBLB requires no additional beam-shaping element and has broad applications such as optical trapping and commercial manufacturing.

  11. Fluoroscopically guided transforaminal epidural dry needling for lumbar spinal stenosis using a specially designed needle

    Directory of Open Access Journals (Sweden)

    Ahn Kang

    2010-08-01

    Full Text Available Abstract Background This report describes the methodological approach and clinical application of a minimally invasive intervention to treat lumbar spinal stenosis (LSS. Methods Thirty-four patients with LSS underwent fluoroscopically guided transforaminal epidural dry needling using a specially designed flexed Round Needle. The needle was inserted 8-12 cm lateral to the midline at the level of the stenosis and advanced to a position between the anterior side of the facet joint and pedicle up to the outer-third of the pedicle. The needle was advanced medially and backed laterally within a few millimetres along the canal side of the inferior articular process between the facet joint and pedicle. The procedure was completed when a marked reduction in resistance was felt at the tip of the needle. The procedure was performed bilaterally at the level of the stenosis. Results The average follow-up period was 12.9 ± 1.1 months. The visual analogue scale (VAS pain score was reduced from 7.3 ± 2.0 to 4.6 ± 2.5 points, the Oswestry Disability Index (ODI score decreased from 41.4 ± 17.2 to 25.5 ± 12.6% and the average self-rated improvement was 52.6 ± 33.1%. The VAS scores indicated that 14 (41.2% patients reported a "good" to "excellent" treatment response, while 11 (32.4% had a "good" to "excellent" treatment response on the ODI and 22 (64.7% had a "good" to "excellent" treatment response on the self-rated improvement scale. Conclusions These results suggest that fluoroscopically guided transforaminal epidural dry needling is effective for managing LSS.

  12. Needle Fracture during Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Suspicious Thoracic Lymph Nodes

    Directory of Open Access Journals (Sweden)

    Bartosz Adamowicz

    2016-01-01

    Full Text Available Endoscopic ultrasound fine-needle aspiration (EUS-FNA is used to make a cytopathologic diagnosis of suspicious lesions located around the gastrointestinal tract. It is a safe technique with few complications. The most common complications of EUS-FNA are related to pancreatic lesions (pancreatitis, bleeding, and abdominal pain. Rare complications have been noted such as stent malfunction, air embolism, infection, neural and vascular injuries, and tumor cell seeding. There are very few studies examining equipment malfunctions. We report a case of needle fracture during the EUS-FNA of suspicious thoracic lymph nodes in a 79-year-old man investigated for unexplained weight loss.

  13. Growth of hollow nickel fluoride whiskers

    International Nuclear Information System (INIS)

    Hollow nickel fluoride whiskers have been obtained by condensation from the vapor phase onto a platinum substrate in a flow of hydrogen fluoride. Crystals up to 5 mm in length have a square cross section with a 300 ± 30-μm side. The wall thickness is 85 ± 20 μm.

  14. High temperature instability of hollow nanoparticles

    Czech Academy of Sciences Publication Activity Database

    Fischer, F. D.; Svoboda, Jiří

    2008-01-01

    Roč. 10, č. 2 (2008), s. 255-261. ISSN 1388-0764 R&D Projects: GA AV ČR IAA200410601 Institutional research plan: CEZ:AV0Z20410507 Keywords : hollow nanoparticle * instability * modelling Subject RIV: BJ - Thermodynamics Impact factor: 2.299, year: 2008

  15. Method for preparing hollow metal oxide microsphere

    Science.gov (United States)

    Schmitt, C.R.

    1974-02-12

    Hollow refractory metal oxide microspheres are prepared by impregnating resinous microspheres with a metallic compound, drying the impregnated microspheres, heating the microspheres slowly to carbonize the resin, and igniting the microspheres to remove the carbon and to produce the metal oxide. Zirconium oxide is given as an example. (Official Gazette)

  16. A prospective randomized controlled trial of Wallace and Rocket embryo transfer catheters.

    Science.gov (United States)

    El-Shawarby, Salem A; Ravhon, Amir; Skull, Jonathan; Ellenbogen, Adrian; Trew, Geoffrey; Lavery, Stuart

    2008-10-01

    The aim of this study was to compare the efficacy of two embryo transfer catheters: Wallace and Rocket Embryon in an IVF programme of a tertiary referral university centre. A total of 308 patients undergoing embryo transfer were prospectively randomized to either a transfer with the Wallace catheter or a transfer with the Rocket catheter. The main outcome measure in this study was the clinical pregnancy rate, and secondary outcome measures included implantation rate, visibility of the catheter under ultrasound, number of retained embryos post transfer, and whether change of catheter was required. In addition, patient discomfort during the procedure was recorded. Pregnancy and implantation rates were similar when Wallace or Rocket catheters were used. However, for the Rocket catheter, the tip was more often clearly seen on ultrasound and it had a lower rate of retained embryos in the catheter after transfer (P < 0.05). Experience with different transfer catheters is recommended for difficult cases. PMID:18854110

  17. Numerical description of discharge characteristics of the plasma needle

    OpenAIRE

    Brok, WJM Wouter; Bowden, MD Mark; van Dijk; Mullen, van der, JJAM Joost; Kroesen, GMW Gerrit

    2005-01-01

    The plasma needle is a small atmospheric, nonthermal, radio-frequency discharge, generated at the tip of a needle, which can be used for localized disinfection of biological tissues. Although several experiments have characterized various qualities of the plasma needle, discharge characteristics and electrical properties are still not well known. In order to provide initial estimates on electrical properties and quantities such as particle densities, we employed a two-dimensional, time-depend...

  18. In vivo Monitoring of Serotonin by Nanomaterial Functionalized Acupuncture Needle

    OpenAIRE

    Yu-Tao Li; Li-Na Tang; Yong Ning; Qing Shu; Feng-Xia Liang; Hua Wang; Guo-Jun Zhang

    2016-01-01

    Acupuncture treatment is amazing but controversial. Up to now, the mechanism of treating diseases by acupuncture and moxibustion is still unclear, especially the occurrence of the molecular events in local acupoints. Herein, we report an extremely stable microsensor by modifying carbon nanotube (CNT) to the tip surface of acupuncture needle and applying this CNT-modified acupuncture needle for real time monitoring of serotonin (5-HT) in vivo. To stabilize CNT modification on the needle tip su...

  19. Cryo-balloon catheter position planning using AFiT

    Science.gov (United States)

    Kleinoeder, Andreas; Brost, Alexander; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2012-02-01

    Atrial fibrillation (AFib) is the most common heart arrhythmia. In certain situations, it can result in life-threatening complications such as stroke and heart failure. For paroxsysmal AFib, pulmonary vein isolation (PVI) by catheter ablation is the recommended choice of treatment if drug therapy fails. During minimally invasive procedures, electrically active tissue around the pulmonary veins is destroyed by either applying heat or cryothermal energy to the tissue. The procedure is usually performed in electrophysiology labs under fluoroscopic guidance. Besides radio-frequency catheter ablation devices, so-called single-shot devices, e.g., the cryothermal balloon catheters, are receiving more and more interest in the electrophysiology (EP) community. Single-shot devices may be advantageous for certain cases, since they can simplify the creation of contiguous (gapless) lesion sets around the pulmonary vein which is needed to achieve PVI. In many cases, a 3-D (CT, MRI, or C-arm CT) image of a patient's left atrium is available. This data can then be used for planning purposes and for supporting catheter navigation during the procedure. Cryo-thermal balloon catheters are commercially available in two different sizes. We propose the Atrial Fibrillation Planning Tool (AFiT), which visualizes the segmented left atrium as well as multiple cryo-balloon catheters within a virtual reality, to find out how well cryo-balloons fit to the anatomy of a patient's left atrium. First evaluations have shown that AFiT helps physicians in two ways. First, they can better assess whether cryoballoon ablation or RF ablation is the treatment of choice at all. Second, they can select the proper-size cryo-balloon catheter with more confidence.

  20. Lab in a needle for epidural space identification

    Science.gov (United States)

    Carotenuto, B.; Micco, A.; Ricciardi, A.; Amorizzo, E.; Mercieri, M.; Cutolo, A.; Cusano, A.

    2016-05-01

    This work relies on the development of a sensorized medical needle with an all-optical guidance (Lab in a Needle) system for epidural space identification. The device is based on the judicious integration of a Fiber Bragg grating sensor inside the lumen of an epidural needle to discriminate between different types of tissue and thus providing continuous and real time measurements of the pressure experienced by the needle tip during its advancement. Experiments carried out on an epidural training phantom demonstrate the validity of our approach for the correct and effective identification of the epidural space.

  1. Steerable real-time sonographically guided needle biopsy.

    Science.gov (United States)

    Buonocore, E; Skipper, G J

    1981-02-01

    A method for dynamic real-time ultrasonic guidance for percutaneous needle biopsy has been successful in obtaining cytologic and histologic specimens from abdominal masses. The system depends on a real-time ultrasonic transducer that has been rigidly attached to a laterally placed steerable needle holder. Using simple trigonometric functions, a chart has been derived that gives the exact angulation and needle length to produce quick, reliable, guided needle placements. Examples of successful renal, hepatobiliary, and retroperitoneal biopsies are presented. Advantages of this technique include speed, accuracy, low cost, three-dimensional format, and the omission of contrast media and radiation. PMID:6781264

  2. Serrated needle design facilitates precise round window membrane perforation.

    Science.gov (United States)

    Stevens, James P; Watanabe, Hirobumi; Kysar, Jeffrey W; Lalwani, Anil K

    2016-07-01

    The round window membrane (RWM) has become the preferred route, over cochleostomy, for the introduction of cochlear implant electrodes as it minimizes inner ear trauma. However, in the absence of a tool designed for creating precise perforation, current practices lead to tearing of the RWM and significant intracochlear pressure fluctuations. On the basis of RWM mechanical properties, we have designed a multi-serrated needle to create consistent holes without membrane tearing or damaging inner ear structures. Four and eight-serrated needles were designed and produced with wire electrical discharge machining (EDM). The needle's ability to create RWM perforations was tested in deidentified, commercially acquired temporal bones with the assistance of a micromanipulator. Subsequently, specimens were imaged under light and scanning electron microscopy (SEM). The needles created consistent, appropriately sized holes in the membrane with minimal tearing. While a four-serrated crown needle made rectangular/trapezoid perforations, the octagonal crown formed smooth oval holes within the membrane. Though designed for single use, the needle tolerated repeated use without significant damage. The serrated needles formed precise perforations in the RWM while minimizing damage during cochlear implantation. The octagonal needle design created the preferred oval perforation better than the quad needle. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 1633-1637, 2016. PMID:26914984

  3. Polychlorinated naphthalenes in pine needles from Poland

    Energy Technology Data Exchange (ETDEWEB)

    Orlikowska, A.; Falandysz, J.; Bochentin, I. [Dept. of Environmental Chemistry and Ecotoxicology, Univ. of Gdansk (Poland); Hanari, N.; Wyrzykowska, B.; Yamashita, N. [National Inst. of Advanced Industrial Science and Technology (AIST), EMTECH, Tsukuba (Japan)

    2004-09-15

    Polychlorinated naphthalenes (PCNs) are a group of 75 compounds, which have been commercially produced and used in a wide range of industrial applications for the sake of their specific chemical properties. They are recognized as good electrical insulators and also as water and flame resistant materials. Technical PCNs formulations were mainly used as capacitor dielectrics, engine oil additives, electroplating stop-off compounds, in wire insulations and as paper, wood and fabric preservatives. Moreover, they have been formed during production of PCBs formulations. Although recently most countries have stopped synthesis of PCNs, they still are widely distributed in the environment. Nowadays the principal sources of these compounds are municipal solid wastes incineration, metallurgical and chloro-alkali processes. In last years PCNs concentrations in the environment have posed the cynosure of big group of scientists in the whole world. The relatively high concentrations are regarded as an environmental problem. Because they are persistent, toxic and lipophilic they might be bioaccumulated in living organisms and generate the danger for animals and humans. It is essentially to monitor their levels in air, regional transport, as well as estimate specific sources. It is possible by using as a biomonitors pine tree needles. These trees are considered as the very suitable passive indicators for monitoring of PCNs concentrations in the troposphere. This is because the surface wax layer of the needles poses an ability to absorb these lipophilic compounds from the surrounding air. In the current study pine needles were employed as biomonitors of PCNs concentrations in the ambient air of Poland. This country with its past history of production and use of different applications including these compounds, as well as with its location in the centre of Europe, presents the interesting region to these researches.

  4. Transbronchial needle aspiration "by the books"

    Directory of Open Access Journals (Sweden)

    Kupeli Elif

    2011-01-01

    Full Text Available Background : Training for advanced bronchoscopic procedures is acquired during the interventional pulmonology (IP Fellowship. Unfortunately a number of such programs are small, limiting dissemination of formal training. Objective : We studied success of conventional transbronchial needle aspiration (C-TBNA in the hands of physicians without formal IP training. Methods : A technique of C-TBNA was learned solely from the literature, videos and practicing on inanimate models at "Hands-On" courses. Conventional TBNA with 21 and/or 19 gauge Smooth Shot Needles (Olympus® , Japan was performed on consecutive patients with undiagnosed mediastinal lymphadenopathy. Results : Thirty-four patients (male 23, mean age 54.9 ± 11.8 years underwent C-TBNA. Twenty-two patients had nodes larger than 20 mms. Suspected diagnoses were malignancy in 20 and nonmalignant conditions in 14. Final diagnoses were malignancy 17, sarcoidosis 4, reactive lymph nodes 12, and tuberculosis 1. Final diagnosis was established by C-TBNA in 14 (11 malignancy, 3 sarcoidosis; yield 41.1%, mediastinoscopy in 14, transthoracic needle aspiration in 3, peripheral lymph node biopsies in 2 and by endobronchial biopsy in 1. Nodal size had an impact on outcome (P = 0.000 while location did not (P = 0.33. C-TBNA was positive in 11/20 when malignancy was suspected (yield 55%, while 3/14 when benign diagnosis was suspected (yield 21.4% (P = 0.05. Sensitivity, specificity, PPV, NPV, and diagnostic accuracy were 66.6%, 100%, 100%, 65%, and 79.4%, respectively. There were no complications or scope damage. Conclusion : Conventional-TBNA can be learned by the books and by practicing on inanimate models without formal training and results similar to those published in the literature could be achieved.

  5. Needle-based confocal laser endomicroscopy

    OpenAIRE

    Giovannini, Marc

    2015-01-01

    New applications of confocal laser endomicroscopy were developed as pCLE in the bile duct and nCLE for pancreatic cystic tumors, pancreatic masses and lymph nodes. The aim of this paper would be to give you an update in this new technology and to try to define its place in the diagnosis of cystic and solid pancreatic masses. The material used was a 19G EUS-needle in which the stylet was replaced by the Confocal mini-probe. The mini-probe (0.632 mm of diameter) is pre-loaded and screwed by a l...

  6. Reformed method of percutaneous port-catheter system implantation via femoral artery

    International Nuclear Information System (INIS)

    Objective: To introduce the techniques of reformed method of percutaneous port-catheter system implantation via femoral artery with evaluation of its safety and advantages. Methods: 60 cases of mid and advance staged malignant tumors received percutaneous port-catheter system implantation via femoral artery by the reformed method. Results: Technical success was achieved in all cases and all procedures were completed within 30 minutes. Complications included one case of delayed healing, three catheter occlusion, two catheter dislodgement and one catheter induced infection. Conclusion: Reformed method of percutaneous port-catheter system implantation via femoral artery is not only feasible and safe, but also it can reduce the occurrence of complications. (authors)

  7. Risk of Needle-track Seeding After Diagnostic Image-guided Core Needle Biopsy in Breast Cancer

    OpenAIRE

    Knight, Rebecca; Horiuchi, Kent; Parker, Steve H.; Ratzer, Erick R.; Fenoglio, Michael E.

    2002-01-01

    Objective: Image-guided core needle biopsy (IGCNB) is an accepted technique for sampling nonpalpable mammographically detected suspicious breast lesions. However, the concern for needle-track seeding in malignant lesions remains. An alternative to IGCNB is needle-localization breast biopsy (NLBB). No study has been done to compare the local recurrence rate of breast cancer after IGCNB versus NLBB. Methods: We have retrospectively reviewed the local recurrence of breast cancer in patients diag...

  8. Transversus Abdominis Plane Catheter Bolus Analgesia after Major Abdominal Surgery

    Directory of Open Access Journals (Sweden)

    Nils Bjerregaard

    2012-01-01

    Full Text Available Purpose. Transversus abdominis plane (TAP blocks have been shown to reduce pain and opioid requirements after abdominal surgery. The aim of the present case series was to demonstrate the use of TAP catheter injections of bupivacaine after major abdominal surgery. Methods. Fifteen patients scheduled for open colonic resection surgery were included. After induction of anesthesia, bilateral TAP catheters were placed, and all patients received a bolus dose of 20 mL bupivacaine 2.5 mg/mL with epinephrine 5 μg/mL through each catheter. Additional bolus doses were injected bilaterally 12, 24, and 36 hrs after the first injections. Supplemental pain treatment consisted of paracetamol, ibuprofen, and gabapentin. Intravenous morphine was used as rescue analgesic. Postoperative pain was rated on a numeric rating scale (NRS, 0–10 at regular predefined intervals after surgery, and consumption of intravenous morphine was recorded. Results. The TAP catheters were placed without any technical difficulties. NRS scores were ≤3 at rest and ≤5 during cough at 4, 8, 12, 18, 24, and 36 hrs after surgery. Cumulative consumption of intravenous morphine was 28 (23–48 mg (median, IQR within the first 48 postoperative hours. Conclusion. TAP catheter bolus injections can be used to prolong analgesia after major abdominal surgery.

  9. Hemodialysis Catheter Heat Transfer for Biofilm Prevention and Treatment.

    Science.gov (United States)

    Richardson, Ian P; Sturtevant, Rachael; Heung, Michael; Solomon, Michael J; Younger, John G; VanEpps, J Scott

    2016-01-01

    Central line-associated bloodstream infections (CLABSIs) are not easily treated, and many catheters (e.g., hemodialysis catheters) are not easily replaced. Biofilms (the source of infection) on catheter surfaces are notoriously difficult to eradicate. We have recently demonstrated that modest elevations of temperature lead to increased staphylococcal susceptibility to vancomycin and significantly soften the biofilm matrix. In this study, using a combination of microbiological, computational, and experimental studies, we demonstrate the efficacy, feasibility, and safety of using heat as an adjuvant treatment for infected hemodialysis catheters. Specifically, we show that treating with heat in the presence of antibiotics led to additive killing of Staphylococcus epidermidis with similar trends seen for Staphylococcus aureus and Klebsiella pneumoniae. The magnitude of temperature elevation required is relatively modest (45-50°C) and similar to that used as an adjuvant to traditional cancer therapy. Using a custom-designed benchtop model of a hemodialysis catheter, positioned with tip in the human vena cava as well as computational fluid dynamic simulations, we demonstrate that these temperature elevations are likely achievable in situ with minimal increased in overall blood temperature. PMID:26501916

  10. Port- a- Cath Catheter placement by general surgery residents

    Directory of Open Access Journals (Sweden)

    F. Schlottmann

    2015-04-01

    Full Text Available In recent years an increasing incidence and prevalence of oncological diseases is observed, with a consequent increase in chemotherapies. In order to avoid repeated venipuncture of patients and toxicity in small veins during different cycles of treatment, devices that provide a permanent central venous access are used. The aim of this study was to evaluate the success and safety of port a cath devices inserted by surgery residents. A consecutive case series of patients in whom Port-a-CathTM catheter was placed by residents of surgery in the period from March 2009 to January 2014 were included. A total of 358 Port-a-CathTM catheters were inserted. Average age 58.7 years (16-88. Females 53.1%. Chemotherapy treatment for solid neoplasias (74.8% and for hematological diseases (25.2%. SThe different venous accesses were: Subclavian (67.6%, Cephalic (27.4%, external jugular (3.3%, internal jugular (1.7%. The morbidity rate was 5.3%, twelve patients with catheter-associated infection requiring the removal of it, 3 venous thrombosis with subsequent replacement of the catheter and 4 patients required pleural drainage. Port-a-CathTM catheter placement by residents is a safe and effective procedure for the administration of chemotherapy

  11. Effect of plastic catheter material on bacterial adherence and viability.

    Science.gov (United States)

    Lopez-Lopez, G; Pascual, A; Perea, E J

    1991-06-01

    The kinetics of adherence of single isolates of Staphylococcus aureus, S. epidermidis, Pseudomonas aeruginosa and Escherichia coli to catheters made of polyvinyl chloride (PVC), Teflon, siliconised latex, polyurethane and Vialon was evaluated by a radiometric assay. Radiolabelled bacteria (10(8) cfu/ml) were incubated in vials containing 1-cm lengths of catheter for up to 3 days. The peak of maximal adherence to each biomaterial was reached after 24 h for P. aeruginosa and after 72 h for the other strains. Bacterial adherence to PVC and siliconised latex was significantly higher (2-6 times; p less than 0.05) than to the other biomaterials for all the strains. The lowest values of adherence were observed with polyurethane and Vialon for the staphylococci but with Teflon for E. coli and P. aeruginosa. Bacterial viability and growth was evaluated in eluates obtained from incubation of segments of each catheter in buffer for 24 h. None of the eluates affected the viability of the staphylococci. However, all of them, significantly increased the growth of E. coli and P. aeruginosa with the exception of the eluate from siliconised latex, in which the inoculum count was reduced to an undetectable level for E. coli. We conclude that bacterial adherence to catheters may depend in part on the nature of the biomaterial and that certain substances eluted from the catheters may affect the viability and growth of different micro-organisms. PMID:1905357

  12. Three-dimensional needle-tip localization by electric field potential and camera hybridization for needle electromyography exam robotic simulator.

    Science.gov (United States)

    He, Siyu; Gomez-Tames, Jose; Yu, Wenwei

    2016-01-01

    As one of neurological tests, needle electromygraphy exam (NEE) plays an important role to evaluate the conditions of nerves and muscles. Neurology interns and novice medical staff need repetitive training to improve their skills in performing the exam. However, no training systems are able to reproduce multiple pathological conditions to simulate real needle electromyogram exam. For the development of a robotic simulator, three components need to be realized: physical modeling of upper limb morphological features, position-dependent electromyogram generation, and needle localization; the latter is the focus of this study. Our idea is to couple two types of sensing mechanism in order to acquire the needle-tip position with high accuracy. One is to segment the needle from camera images and calculate its insertion point on the skin surface by a top-hat transform algorithm. The other is voltage-based depth measurement, in which a conductive tissue-like phantom was used to realize both needle-tip localization and physical sense of needle insertion. For that, a pair of electrodes was designed to generate a near-linear voltage distribution along the depth direction of the tissue-like phantom. The accuracy of the needle-tip position was investigated by the electric field potential and camera hybridization. The results showed that the needle tip could be detected with an accuracy of 1.05±0.57 mm. PMID:27382339

  13. CT-guided transthoracic cutting needle biopsy of intrathoracic lesions: Comparison between coaxial and single needle technique

    International Nuclear Information System (INIS)

    Purpose: To evaluate the complication rates and diagnostic accuracy of two different CT-guided transthoracic cutting needle biopsy techniques: coaxial method and single needle method. Methods: This study involved 198 consecutive subjects with 198 intrathoracic lesions. The first 98 consecutive subjects received a single needle cutting technique and the next 100 consecutive subjects received a coaxial technique. Both groups were compared in relation the diagnostic accuracy and complication rates. Results: No significant difference was found between the two groups concerning patient characteristics, lesions and procedure variables. There was a borderline statistical difference in the incidence of pneumothorax at within 24-h post biopsy between patients in the single needle group (5%) and the coaxial group (13%) (P = 0.053). Little difference was found in the pneumothorax rate at immediately post biopsy between the two groups, which was 28% in the single needle group and 31% in the coaxial group. There was no significant difference in the hemoptysis rate between the two groups, which was 9.2% in the single needle group and 11% in the coaxial group. Both techniques yielded an overall diagnostic accuracy of 98% for malignant lesions with similar sensitivity (single needle: 96.9% vs. coaxial: 96.4%) and specificity (single needle: 100% vs. coaxial: 100%). Conclusion: There is little difference in the pneumothorax rates and bleeding complications between patients who either received a single needle or a coaxial transthoracic cutting biopsy. Both techniques produce an overall diagnostic accuracy of 98% for malignant lesions.

  14. Placement of a Hemodialysis Catheter using the Dilated Right External Jugular Vein as a Primary Route

    Energy Technology Data Exchange (ETDEWEB)

    Park, Mi Hyun [Dankook University Hospital, Cheonan (Korea, Republic of); Shin, Byung Seok [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2010-08-15

    To evaluate the feasibility that a dilated right external jugular vein (EJV) could be a primary venous access site for large bore hemodialysis catheter placement. Between January 2008 and April 2009, a total of 173 hemodialysis catheters (14.5 F) were placed. Among them, we evaluated the clinical data of 42 patients who underwent placement through a dilated right EJV. We evaluated technical success, duration of catheterization in days, and the presence of complications. Technical success was achieved for 41 patients (98%). Catheter placement was unsuccessful in one patient due to narrowing of the EJV. The catheter dwell time ranged between 14 and 305 days (mean; 76 days, total catheter days: 3,111 days). A total of 26 hemodialysis catheters were removed due to complications (n=2) and termination of hemodialysis via the hemodialysis catheter (n=24). There was air embolization (n=1) and catheter kinking (n=3) during procedures and catheter related infections (n=2) during the follow-up period. The incidence of catheter related infection was 0.06 per 100 catheter days. No cases of catheter malfunction or symptomatic venous thrombosis were observed. We suggest that a dilated right EJV could be considered as a preferred primary route for hemodialysis catheter placement with easy access

  15. Compatibility of electrolytically produced sodium hypochlorite solutions on long- term implanted dialysis catheters.

    Science.gov (United States)

    Mishkin, G J

    2007-01-01

    More than 20% of the world's population use a catheter for dialysis, despite guidelines limiting their use. Although the structure and design of the catheters differ by manufacturer, the material used in central venous catheters and peritoneal dialysis catheters are the same across manufacturers. Given the long-term use of these catheters in the dialysis population, the good compatibility of the antiseptics and disinfectants used on the catheters is imperative to prevent failure and cracking of the catheter material. Tensile strengths of commercially available catheters were measured after exposure to commonly used disinfectants. The tensile strength was then compared between the catheters by analyzing the displacement vs. force (N) curves produced during the evaluation. A total of 44 catheter lumens were evaluated. The electrolytically produced sodium hypochlorite solution, Alcavis 50/ExSept Plus, was the only solution shown to be compatible with all three catheter materials resulting in a deviation of less than 10% for each of the different catheter types. Electrolytically produced sodium hypochlorite solutions were the only solutions in this study that did not alter the physical properties of any of the catheters after long-term exposure. PMID:17099302

  16. Comparison of outcomes between surgically placed and percutaneously placed peritoneal dialysis catheters: A retrospective study.

    Science.gov (United States)

    Sivaramakrishnan, R; Gupta, S; Agarwal, S K; Bhowmik, D; Mahajan, S

    2016-01-01

    There is lack of adequate data on comparison of outcomes between percutaneously placed peritoneal dialysis (PD) catheters inserted by nephrologists and PD catheters placed by surgeons. The aim of this study is to retrospectively analyze the outcomes of PD catheters inserted by surgeons (by open surgical or laparoscopic technique) and compare them with those inserted by nephrologists among ESRD patients who underwent elective PD catheter insertions between January 2009 and December 2012. The primary outcome measure was the proportion of catheters removed because of primary nonfunction. The secondary outcome measures were catheter survival, patient survival, and incidence of complications of catheter insertion. A total of 143 PD catheter insertions (88 by surgeons and 55 by nephrologists) performed in 132 patients were considered for the analysis. The primary nonfunction rate of PD catheter insertions in both groups was comparable (18.2% and 7.3%, P = 0.08). Break-in period was shorter in Group N (p = <0.001). No differences were noted in patient or catheter survival. Percutaneously placed PD catheters performed by nephrologists have comparable outcomes with surgically placed PD catheters among selected cases and have the advantage of lower costs, avoidance of operation theater scheduling issues, smaller incision length, and shorter break-in period. Therefore, more nephrologists should acquire the expertise on percutaneous PD catheter placement as it leads to lesser waiting times and better utilization of PD. PMID:27512299

  17. Characteristics of Left-Right Spiral Hollow Cylindrical Roller

    Institute of Scientific and Technical Information of China (English)

    Liming Lu; Qiping Chen; Yujiang Qin

    2015-01-01

    Based on new rolling⁃sliding compound bearings, the wear between the one⁃way spiral hollow cylindrical roller and the ribs of the inner and outer ring of rolling⁃sliding compound bearings is reduced by innovational structural design. A new left⁃right spiral hollow cylindrical roller is proposed to replace the one⁃way spiral hollow cylindrical roller. The finite element analysis models of ordinary cylindrical rollers, one⁃way spiral hollow cylindrical rollers and left⁃right spiral hollow cylindrical rollers are respectively established by ABAQUS. The axial displacement of their center mass and the stress distribution of left⁃right spiral hollow cylindrical rollers are compared and analyzed. Theoretical study results show that this new left⁃right spiral hollow cylindrical roller not only inherits the advantages of one⁃way spiral hollow cylindrical rollers, but also avoids the axial offset and the serious wear of the one⁃way spiral hollow cylindrical roller. And the theory research conclusion is verified by the experiment. The left⁃right spiral hollow cylindrical roller has the advantages to overcome boundary stress concentration like logarithmic convex roller. The rolling⁃sliding compound bearings equipped with the new rollers can be better to adapt to the impact of vibration load.

  18. Needle placement accuracy during stereotactic localization mammography

    International Nuclear Information System (INIS)

    Aim: To derive a mathematical model to describe the relationship between lesion position in the breast and measurements derived from the stereoradiographs to enable more accurate sampling of a lesion during stereotactic mammographic needle placement. Materials and methods: The affect that registration errors have on the accuracy of needle placement when identifying the lesion on the stereoradiographs was investigated using the mathematical model. Results: The focus-to-film distance of the x-ray tube and the horizontal distance of the lesion from the centre of rotation have little effect on error. Registration errors for lesions lying at a greater perpendicular distance in the breast from the centre of rotation produce smaller localization errors when compared with lesions sited closer. Lesion registration errors during marking of the stereoradiographs are exacerbated by decreasing the angle of x-ray tube swing. Conclusions: When problems are encountered in making an accurate registration of the lesion on the stereoradiographs, consider the following error reducing strategies: (1) employ an approach that places the lesion the maximum distance away from the film cassette; (2) avoid reducing the angle of tube swing; and (3) consider sampling superficial and deep to, as well as at, the location indicated. The possibility of erroneous tissue sampling should be borne in mind when reviewing the pathology report.

  19. The Hunter Pulmonary Angiography Catheter for a Brachiocephalic Vein Approach

    International Nuclear Information System (INIS)

    The purpose of this work was to describe our experience in performing pulmonary angiography using the Hunter pulmonary catheter, manufactured by Cook, Inc., which is a modified 6F pigtail catheter with a 'C-shaped' curve, designed for a brachiocephalic vein approach. One hundred twenty-three patients underwent pulmonary angiograms using the Hunter catheter between August 1997 and January 2002. Operator comments were gathered in 86 (70%) of the cases. The operator was, if possible, the most junior resident on the service. Thirty-nine operators participated in the survey. Efficacy, safety, and ease of use of the catheter were determined by operators' comments and ECG observations during the procedure. Corroborating clinical data were gathered from medical records. In 68 (79%) of the procedures that were commented upon, the operator described insertion into the pulmonary artery (PA) as easy; only 2 (2%) indicated difficulty in accessing the PA. In 41 (63%) of the bilateral angiograms that were commented upon, the operator described accessing the left PA from the right PA as easy; only 6 (9%) rated it as difficult and all were with an older technique in which the catheter was withdrawn to the pulmonary bifurcation without a wire or with only the soft tip of the wire in the pigtail and then rotated to the left main pulmonary artery. Thirty-one of the 41 patients who demonstrated premature ventricular contractions (PVCs) had a previous history of heart disease. Nineteen of the 39 patients who did not have PVCs had a history of heart disease (p = 0.018). The maneuverability and shape of the Hunter catheter make pulmonary angiography an easy procedure, even for operators with minimal experience and limited technical proficiency. PVCs demonstrated a statistically significant correlation with a positive patient history for cardiac disease, rather than being a universal risk

  20. Three-dimensional needle-tip localization by electric field potential and camera hybridization for needle electromyography exam robotic simulator

    Directory of Open Access Journals (Sweden)

    He SY

    2016-06-01

    Full Text Available Siyu He,1 Jose Gomez-Tames,1 Wenwei Yu1,2 1Medical System Engineering Department, Graduate School of Engineering, 2Center for Frontier Medical Engineering, Chiba University, Chiba, Japan Abstract: As one of neurological tests, needle electromygraphy exam (NEE plays an important role to evaluate the conditions of nerves and muscles. Neurology interns and novice medical staff need repetitive training to improve their skills in performing the exam. However, no training systems are able to reproduce multiple pathological conditions to simulate real needle electromyogram exam. For the development of a robotic simulator, three components need to be realized: physical modeling of upper limb morphological features, position-dependent electromyogram generation, and needle localization; the latter is the focus of this study. Our idea is to couple two types of sensing mechanism in order to acquire the needle-tip position with high accuracy. One is to segment the needle from camera images and calculate its insertion point on the skin surface by a top-hat transform algorithm. The other is voltage-based depth measurement, in which a conductive tissue-like phantom was used to realize both needle-tip localization and physical sense of needle insertion. For that, a pair of electrodes was designed to generate a near-linear voltage distribution along the depth direction of the tissue-like phantom. The accuracy of the needle-tip position was investigated by the electric field potential and camera hybridization. The results showed that the needle tip could be detected with an accuracy of 1.05±0.57 mm. Keywords: needle-tip localization, needle EMG exam, top-hat transform, tissue-like phantom, voltage distribution simulation

  1. 21 CFR 868.5090 - Emergency airway needle.

    Science.gov (United States)

    2010-04-01

    ... provide an emergency airway during upper airway obstruction. (b) Classification. Class II (performance... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Emergency airway needle. 868.5090 Section 868.5090...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5090 Emergency airway needle....

  2. Coaxial needle insertion assistant with enhanced force feedback.

    Science.gov (United States)

    De Lorenzo, Danilo; Koseki, Yoshihiko; De Momi, Elena; Chinzei, Kiyoyuki; Okamura, Allison M

    2013-02-01

    Many medical procedures involving needle insertion into soft tissues, such as anesthesia, biopsy, brachytherapy, and placement of electrodes, are performed without image guidance. In such procedures, haptic detection of changing tissue properties at different depths during needle insertion is important for needle localization and detection of subsurface structures. However, changes in tissue mechanical properties deep inside the tissue are difficult for human operators to sense, because the relatively large friction force between the needle shaft and the surrounding tissue masks the smaller tip forces. A novel robotic coaxial needle insertion assistant, which enhances operator force perception, is presented. This one-degree-of-freedom cable-driven robot provides to the operator a scaled version of the force applied by the needle tip to the tissue, using a novel design and sensors that separate the needle tip force from the shaft friction force. The ability of human operators to use the robot to detect membranes embedded in artificial soft tissue was tested under the conditions of 1) tip force and shaft force feedback, and 2) tip force only feedback. The ratio of successful to unsuccessful membrane detections was significantly higher (up to 50%) when only the needle tip force was provided to the user. PMID:23193302

  3. Synthesis of nano-crystalline multifibrous zirconia needle

    International Nuclear Information System (INIS)

    Graphical abstract: - Highlights: • Zirconia needles have been successfully prepared by simple inorganic sol–gel route. • The shape of the needles was retained after firing with aspect ratio > 400. • Needles are composed of multiple fibres. • Fibres are composed of nano crystals. - Abstract: Zirconia needles have been successfully synthesized using a simple inorganic sol–gel process without using any template. The method employs mixture of zirconium oxychloride octahydrate and sulphuric acid in aqueous medium. This process requires heat treatment at 40 °C for 2 h in an oven for nucleus formation. Complete formation of needle occurs after 17 days. The green needle retained its original shape after calcination at 1200 °C. Fired needles were of 1–2 cm in length and 5–50 μm in diameter and possess monoclinic phase. Needles are composed of multiple fibres. Depending on the heat treatment temperature, crystallite size varies in the range of 8 to around 300 nm

  4. Laser-Controlled Growth of Needle-Shaped Organic Nanoaggregates

    DEFF Research Database (Denmark)

    Balzer, Frank; Rubahn, Horst-Günter

    2002-01-01

    Arrays of mutually parallel oriented, single-crystalline, needle-like structures of light-emitting p-hexaphenyl molecules are generated in the focus of an argon ion laser. The cross sectional dimensions of the needles are of the order of 100 to 200 nm with lengths up to several hundred micrometers...

  5. Space Charge Mitigation by Hollow Bunches

    CERN Multimedia

    Oeftiger, AO

    2014-01-01

    To satisfy the requirements of the HL-LHC (High Luminosity Large Hadron Collider), the LHC injector chain will need to supply a higher brightness, i.e. deliver the same transverse beam emittances \\epsilon_{x,y} while providing a higher intensity N. However, a larger number of particles per bunch enhances space charge effects. One approach to mitigate the impact of space charge is to change the longitudinal phase space distribution: hollow bunches feature a depleted bunch centre and a densely populated periphery. Thus, the spatial line density maximum is depressed which ultimately decreases the tune spread imposed by space charge. Therefore, a higher intensity can be accepted while keeping the same overall space charge tune shift. 3 different methods to create hollow bunches in the PSBooster are simulated.

  6. Characterizing the elasticity of hollow metal nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Ji Changjiang; Park, Harold S [Department of Civil and Environmental Engineering, Vanderbilt University, Nashville, TN 37235 (United States)

    2007-03-21

    We have performed atomistic simulations on solid and hollow copper nanowires to quantify the elastic properties of hollow nanowires (nanoboxes). We analyse variations in the modulus, yield stress and strain for <100> and <110> nanoboxes by varying the amount of bulk material that is removed to create the nanoboxes. We find that, while <100> nanoboxes show no improvement in elastic properties as compared to solid <100>nanowires, <110> nanoboxes can show enhanced elastic properties as compared to solid <110> nanowires. The simulations reveal that the elastic properties of the nanoboxes are strongly dependent on the relative strength of the bulk material that has been removed, as well as the total surface area of the nanoboxes, and indicate the potential of ultralight, high-strength nanomaterials such as nanoboxes.

  7. Trapping Iron Oxide into Hollow Gold Nanoparticles

    Directory of Open Access Journals (Sweden)

    Sun Xiankai

    2011-01-01

    Full Text Available Abstract Synthesis of the core/shell-structured Fe3O4/Au nanoparticles by trapping Fe3O4 inside hollow Au nanoparticles is described. The produced composite nanoparticles are strongly magnetic with their surface plasmon resonance peaks in the near infrared region (wavelength from 700 to 800 nm, combining desirable magnetic and plasmonic properties into one nanoparticle. They are particularly suitable for in vivo diagnostic and therapeutic applications. The intact Au surface provides convenient anchorage sites for attachment of targeting molecules, and the particles can be activated by both near infrared lights and magnetic fields. As more and more hollow nanoparticles become available, this synthetic method would find general applications in the fabrication of core–shell multifunctional nanostructures.

  8. A new method for quantifying the needling component of acupuncture treatments

    OpenAIRE

    Davis, Robert T; Churchill, David L; Badger, Gary J; Dunn, Julie; Langevin, Helene M

    2012-01-01

    Objectives The highly variable nature of acupuncture needling creates challenges to systematic research. The goal of this study was to test the feasibility of quantifying acupuncture needle manipulation using motion and force measurements. It was hypothesised that distinct needling styles and techniques would produce different needle motion and force patterns that could be quantified and differentiated from each other. Methods A new needling sensor tool (Acusensor) was used to record needling...

  9. Spontaneous migration of central venous catheter tip following extubation

    Directory of Open Access Journals (Sweden)

    Balaji Prabaharan

    2014-01-01

    Full Text Available Migration of the tip of central venous catheters is not an uncommon event and the mechanism for this is not clear. Increased intrathoracic pressure due to coughing, sneezing or weight lifting, changing the body position or physical movements such as abduction or adduction of the arms is thought to be the cause of such migration. We present here a case of a patient with a port catheter tip that migrated from the left subclavian to the superior vene cava following extubation.

  10. CT imaging of complications of catheter ablation for atrial fibrillation

    International Nuclear Information System (INIS)

    The complication rate following radiofrequency catheter ablation for atrial fibrillation is low (<5%). Complications include pericardial effusion, cardiac tamponade, pulmonary vein stenosis, oesophageal ulceration or perforation, atrio-oesophageal fistula formation, stroke/transient ischaemic attack, phrenic nerve injury, haematoma at the puncture site, and femoral arteriovenous fistula. Among available imaging tools, computed tomography (CT) can be very useful in diagnosing complications of the procedure, particularly in the subacute and delayed stages after ablation. This review illustrates CT imaging of several of the common and uncommon complications of radiofrequency catheter ablation

  11. Central venous catheters for chemotherapy of solid tumors--our results in the last 5 years.

    Science.gov (United States)

    Zganjer, Mirko; Cizmić, Ante; Butković, Diana; Matolić, Martina; Karaman-Ilić, Maja; Stepan, Jasminka

    2008-09-01

    Central venous catheters provide an easy access for intravenous medications. Having a central line in place will relieve a child from the discomfort and danger of multiple regular intravenous lines for chemotherapy. The use of indwelling central venous catheters has become commonplace in the management of children undergoing oncological treatment. There are two types of central lines commonly used. There are Broviac catheters and Port-A-Cath (PAC) catheters. In the last 5 years we inserted 194 catheters in 175 children. We inserted 121 Broviac catheters and 73 PAC catheters. During the follow up of 39382 catheter days 44 complications were observed. In Broviac group the median follow up was 155 days and in PAC group was 230 days. We observed differences in the incidence between two devices. In Broviac group infections were more frequent and in PAC group other complications were more frequent than infections. PMID:18982750

  12. Effect of plastic catheters on the phagocytic activity of human polymorphonuclear leukocytes.

    Science.gov (United States)

    López-López, G; Pascual, A; Perea, E J

    1990-05-01

    The effect of five kinds of plastic catheters (polyvinyl chloride, Teflon, polyurethane, Vialon and siliconized latex) on the phagocytic and bactericidal function of human polymorphonuclear leukocytes was evaluated. In the presence of the polyvinyl chloride, Teflon and siliconized latex catheters, superoxide radical production by polymorphonuclear leukocytes was significantly inhibited. The effect of the siliconized latex catheter was presumably mediated by products eluted from the catheter into the medium, since the incubation of polymorphonuclear leukocytes in eluates obtained from the incubation of this catheter in buffer induced a similar inhibitory effect. This phenomenon was not observed with polyurethane or Vialon catheters. Neither the catheters evaluated nor their eluates affected the uptake of opsonized Staphylococcus aureus by human polymorphonuclear leukocytes. It is concluded that the polyvinyl chloride, Teflon and siliconized latex catheters used in this study could impair the respiratory burst of human polymorphonuclear leukocytes. PMID:2164932

  13. Radiologic interventional retrieval of retained central venous catheter fragment in prematurity: case report

    International Nuclear Information System (INIS)

    The fracture of a central venous catheter is a rare but potentially serious complication. Moreover, removal of the broken catheter pieces is considerably challenging, especially for premature infants. We report 3 case studies of the percutaneous transcatheter retrieval of broken catheter parts in 3 premature infants. We confirmed the location of the catheter fragments via a DSA venogram with diluted contrast media. Using the minimum amount of contrast, and extreme caution, we made certain no contrast-induced nephrotoxicity of air embolism occurred during catheter manipulation. In addition, when the broken fragment was curled or attached to the cardiac wall, we used a hook-shaped catheter to facilitate the capturing of the catheter with a loopsnare. This report demonstrates the feasibility of removing a retained catheter fragment in a premature infant using a percutaneous transcatheter approach

  14. Evaluation of Fiber Bundle Rotation for Enhancing Gas Exchange in a Respiratory Assist Catheter

    OpenAIRE

    Eash, Heide J.; Mihelc, Kevin M.; Frankowski, Brain J.; Hattler, Brack G.; Federspiel, William J.

    2007-01-01

    Supplemental oxygenation and carbon dioxide removal through an intravenous respiratory assist catheter can be used as a means of treating patients with acute respiratory failure. We are beginning development efforts toward a new respiratory assist catheter with an insertional size

  15. Fluoroscopy guided percutaneous catheter drainage of pneumothorax in good mid-term patency with tube drainage

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ga Young; Oh, Joo Hyung; Yoon, Yup; Sung, Dong Wook [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1995-10-15

    To evaluate efficacy and the safety of percutaneous catheter drainage in patients with pneumothorax that is difficult to treat with closed thoracotomy. We retrospectively reviewed effectiveness of percutaneous catheter drainage (PCD) in 10 patients with pneumothorax. The catheter was inserted under fluoroscopic guidance. Seven patients had spontaneous pneumothorax caused by tuberculosis (n =4), reptured bullae (n = 2), and histiocytosis-X (n = 1). Three patients had iatrogenic pneumothorax caused by trauma (n = 1) and surgery (n = 2). All procedures were performed by modified Seldinger's method by using 8F-20F catheter. All catheter were inserted successfully. In 9 of 10 patients, the procedure was curative without further therapy. Duration of catheter insertion ranged from 1 day to 26 days. In the remaining 1 patient in whom multiple pneumothorax occurred after operation, catheter insertion was performed twice. Percutaneous catheter drainage under fluoroscopic guidance is effective and safe procedure for treatment of pneumothorax in patients with failed closed thoracotomy.

  16. Fluoroscopy guided percutaneous catheter drainage of pneumothorax in good mid-term patency with tube drainage

    International Nuclear Information System (INIS)

    To evaluate efficacy and the safety of percutaneous catheter drainage in patients with pneumothorax that is difficult to treat with closed thoracotomy. We retrospectively reviewed effectiveness of percutaneous catheter drainage (PCD) in 10 patients with pneumothorax. The catheter was inserted under fluoroscopic guidance. Seven patients had spontaneous pneumothorax caused by tuberculosis (n =4), reptured bullae (n = 2), and histiocytosis-X (n = 1). Three patients had iatrogenic pneumothorax caused by trauma (n = 1) and surgery (n = 2). All procedures were performed by modified Seldinger's method by using 8F-20F catheter. All catheter were inserted successfully. In 9 of 10 patients, the procedure was curative without further therapy. Duration of catheter insertion ranged from 1 day to 26 days. In the remaining 1 patient in whom multiple pneumothorax occurred after operation, catheter insertion was performed twice. Percutaneous catheter drainage under fluoroscopic guidance is effective and safe procedure for treatment of pneumothorax in patients with failed closed thoracotomy

  17. Dialysis catheter-related septicaemia--focus on Staphylococcus aureus septicaemia

    DEFF Research Database (Denmark)

    Nielsen, J; Ladefoged, S D; Kolmos, H J

    1998-01-01

    BACKGROUND: Dialysis catheters are a common cause of nosocomial septicaemia in haemodialysis units usually due to staphylococci, of which Staphylococcus aureus is the most pathogenic. In this study, the epidemiology and pathogenesis of dialysis catheter-related infections were studied, and methods....../67) of all catheter periods--84% of these were due to coagulase-negative staphylococci. CONCLUSIONS: Dialysis catheter-related S. aureus septicaemia was highly unlikely if the patient had not been carrying S. aureus in the nose or at the insertion site during the time the catheter was in place. The best...... predictor of dialysis catheter-related S. aureus septicaemia was a positive S. aureus culture from the insertion site. Positive catheter blood cultures unrelated to any clinical signs of septicaemia occurred in one-third of all catheter periods, and 84% of these were due to coagulase-negative staphylococci....

  18. Clinical efficacy and safety of catheter ablation for atrial fibrillation in elderly patients

    Institute of Scientific and Technical Information of China (English)

    董静

    2013-01-01

    Objective To evaluate the clinical efficacy and safty of catheter ablation for atrial fibrillation in elderly patients.Methods From September 2008 to October 2011,a total of 420 consecutive patients undergoing cathete rablation

  19. Radiologic interventional retrieval of retained central venous catheter fragment in prematurity: case report

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jee Won; Jo, Jung Hyun; Park, Byeong Ho [College of Medicine, Dong-A University, Busan (Korea, Republic of)

    2007-12-15

    The fracture of a central venous catheter is a rare but potentially serious complication. Moreover, removal of the broken catheter pieces is considerably challenging, especially for premature infants. We report 3 case studies of the percutaneous transcatheter retrieval of broken catheter parts in 3 premature infants. We confirmed the location of the catheter fragments via a DSA venogram with diluted contrast media. Using the minimum amount of contrast, and extreme caution, we made certain no contrast-induced nephrotoxicity of air embolism occurred during catheter manipulation. In addition, when the broken fragment was curled or attached to the cardiac wall, we used a hook-shaped catheter to facilitate the capturing of the catheter with a loopsnare. This report demonstrates the feasibility of removing a retained catheter fragment in a premature infant using a percutaneous transcatheter approach.

  20. Hollow Sucker Rod Applied in Production Engineering

    Institute of Scientific and Technical Information of China (English)

    Wang Tongbin; Liu Liandong; Hu Daoming; Jia Yanshan

    1997-01-01

    @@ Working Principle A positive cycle system or a working channel can be formed by means of hollow sucker rod and its mating parts in the oil tube ofa well, through which heat carriers (such as hot water,hot oil and steam), chemicals and heating cable can be pumped or put into the well so as to lower the viscosity of crude, dissolve the paraffin building-up and open the conduit, thus leading to the smooth oil flow out of well.

  1. Hollow Cathode With Multiple Radial Orifices

    Science.gov (United States)

    Brophy, John R.

    1992-01-01

    Improved hollow cathode serving as source of electrons has multiple radial orifices instead of single axial orifice. Distributes ion current more smoothly, over larger area. Prototype of high-current cathodes for ion engines in spacecraft. On Earth, cathodes used in large-diameter ion sources for industrial processing of materials. Radial orientation of orifices in new design causes current to be dispersed radially in vicinity of cathode. Advantageous where desireable to produce plasma more nearly uniform over wider region around cathode.

  2. Trapping of intense light in hollow shell

    International Nuclear Information System (INIS)

    A small hollow shell for trapping laser light is proposed. Two-dimensional particle-in-cell simulation shows that under appropriate laser and plasma conditions a part of the radiation fields of an intense short laser pulse can enter the cavity of a small shell through an over-critical density plasma in an adjacent guide channel and become trapped. The trapped light evolves into a circulating radial wave pattern until its energy is dissipated

  3. Hollow cathode startup using a microplasma discharge

    Science.gov (United States)

    Aston, G.

    1981-01-01

    Attention is given to a microplasma discharge to initiate a hollow cathode discharge for such applications as plasma flow experiments, the electric propulsion of space vehicles, and as a replacement for filament cathodes in neutral beam injector ion sources. The technique results in a cathode that is easy to start, simple in design, and which does not require external RF exciters, inserts or heating elements. Future applications may include ion beam milling and ion implantation.

  4. Wedge - rolls rolling of hollowed parts

    Directory of Open Access Journals (Sweden)

    Z. Pater

    2006-08-01

    Full Text Available Purpose: Presentation of the possibilities of application of a new manufacturing method, called wedge rollsrolling (WRR in forming of axi – symmetrical hollowed parts.Design/methodology/approach: The research work was done in a specially designed laboratory rolling millLUW-2. During the research, hollowed parts from steel were rolled in hot forming conditions. Basic kinematicaland force parameters of the process were noticed during rolling.Findings: On the basis of the conducted research it was stated that the WRR method could be used for formingof hollowed parts with the precision compared with the precision obtained in the typical cross wedge rollingprocesses (CWR. At the same time, it was proved that this method could be used for rolling from billets withthe wall thinner than the wall given in the CWR.Research limitations/implications: The research were limited to the wedges with spreading angles withinrange of β = (5° ÷ 9°, with the constant values of forming angle α = 30° and relative reduction ratio δ = 1.45.In the future, it is planned to analyse the influence of changes of angle α and relative reduction ratio δ on theWRR process.Practical implications: The conducted research can be used for designing of a new industrial method of metalforming of hollowed parts.Originality/value: The innovation of this solution is based on the application of only one wedge for forming.Because of that, the WRR method is cheaper for implementation than used so far CWR processes. This methodcan be applied mainly in automotive and aviation industries.

  5. Hollow vortices and wakes past Chaplygin cusps

    OpenAIRE

    Lasagna, Davide; Zannetti, Luca

    2013-01-01

    By using analytic tools for 2D rotational inviscid flow, the stagnation points of Pocklington hollow vortices are replaced by Chaplygin cusps, that is, by regions of fluid at rest. By solidifying the bounding free streamlines, solid bodies are obtained along whose walls adverse pressure gradients are avoided. These results are relevant to the theory and practice of control of separated flow at high Reynolds number. Examples are presented pertinent to single bodies and cascade of bodies which ...

  6. Effect of physical disturbance on the structure of needle coke

    Science.gov (United States)

    Zhao, Shi-Gui; Wang, Bao-Cheng; Sun, Quan

    2010-10-01

    Through different preparation technology, this paper reports that the needle coke is prepared with coal-tar pitch under the effect of magnetic field and ultrasonic cavitation. It studies the effect of physical disturbance on the structure of needle coke. The structure of needle coke is characterized by scanning electron microscope and x-ray diffractometer, and the influence mechanism is analysed. Results showed that the structure and property of needle coke could be effectively improved by magnetic field and ultrasonic cavitations, such as degree of order, degree of graphitization and crystallization. Comparatively speaking, the effect of magnetic field was greater. The graphitization degree of needle coke prepared under the effect of magnetic field is up to 45.35%.

  7. CUDA accelerated simulation of needle insertions in deformable tissue

    Science.gov (United States)

    Patriciu, Alexandru

    2012-10-01

    This paper presents a stiff needle-deformable tissue interaction model. The model uses a mesh-less discretization of continuum; avoiding thus the expensive remeshing required by the finite element models. The proposed model can accommodate both linear and nonlinear material characteristics. The needle-deformable tissue interaction is modeled through fundamental boundaries. The forces applied by the needle on the tissue are divided in tangent forces and constraint forces. The constraint forces are adaptively computed such that the material is properly constrained by the needle. The implementation is accelerated using NVidia CUDA. We present detailed analysis of the execution timing in both serial and parallel case. The proposed needle insertion model was integrated in a custom software that loads DICOM images, generate the deformable model, and can simulate different insertion strategies.

  8. The New-Generation Technology for Making Petroleum Needle Coke

    Institute of Scientific and Technical Information of China (English)

    Shi Changzhi; Shen Haiping; Long Jun; Xie Changjiang

    2003-01-01

    The current technology for producing the petroleum needle coke is apt to cause overflow of feedstock from the coke drums, instability in operation of coking unit, low mechanical strength of petroleum coke, and high percentage of coke powder, leading to difficulties in improving the overall quality of needle coke. Therefore, we have developed a new technology for producing the needle coke,featuring the manipulation of temperature range in a narrow scale at high pressure coupled with feedstock alternations. This new kind of technology has been successfully applied in a 60kt/a commercial coking unit. Provided that demand for the feedstock quality is satisfied, petroleum needle coke meeting the international quality standard can be manufactured using RIPP's technology for producing petroleum needle coke.

  9. Disconnection of chamber and catheter as a complication of central venous catheter type port-a-cath.

    Science.gov (United States)

    Kostic, S; Kovcin, V; Granić, M; Jevdic, D; Stanisavljevic, N

    2011-12-01

    The use of a central vein catheter (CVC) type port-a-cath (VPS), apart from the comfort it provides to the patient undergoing chemotherapy, also carries certain complications. In this study, our patient was subjected to chemotherapy after a radical breast cancer operation and was given a CVC type VPS. After further care, a rare complication was verified--disconnection of the chamber and catheter, which one was visually identified in the right heart chamber. As the patient was vitally endangered, she was immediately hospitalized and the catheter was removed by catheterization of the right femoral vein, with scopic imaging. Early diagnosis and localization of the problem prevented more severe complications and mortality. PMID:20607455

  10. Synthesis of hollow polymer microspheres by dynamic swelling method

    International Nuclear Information System (INIS)

    Hollow polymer microspheres about 5 μm in diameter were synthesized by dynamic swelling method using micron- sized polystyrene spheres with positive charges on surfaces as seeds. The synthesis process included swelling by organic solvents such as toluene and divinylbenzene, polymerizing and coating. The influences of variety and dosage of organic solvents on diameter, size distribution and hole structure of hollow microspheres were investigated, and the formation mechanism of hollow microspheres was discussed. It is indicated that some volatile organic solvents, such as toluene and dimethylbenzene, are crucial to hollow structure formation. Experimental results show that, more toluene leads to larger hollow structure after swelling, and dimethylbenzene is good for hollow structure formation, owing to its low solubility. (authors)

  11. Evaluation of vascular puncture needles with specific modifications for enhanced ultrasound visibility: In vitro study

    Directory of Open Access Journals (Sweden)

    Nobuyuki Kawai

    2012-01-01

    Full Text Available AIM: To determine which modification to a vascular puncture needle results in increased visualization during ultrasound (US-guided vascular puncture. METHODS: We evaluated US images of a phantom made of degassed gelatin and each of the following four modified versions of a commercially available vascular puncture needle (18 G: re-cut needle, dimple needle, rough-surface needle (rough over the sections of needle located 3-6 mm from the tip, and a needle with four side holes (side holes covered by the sheath. An unmodified commercially available puncture needle was used as a control. Five interventional radiologists evaluated image quality according to the following classification grade: I, invisible; II, poor; III, moderate; IV, good; V, excellent. RESULTS: The highest score for needle visualization was obtained for the needle with four side holes. The re-cut needle scored the same as the control. Multiple comparisons were conducted using overall evaluation scores among the commercially available needle, dimple needle, rough-surface needle (3-6 mm, and the needle with four side holes. A significantly higher score was obtained for the needle with four side holes (P < 0.05/6. CONCLUSION: The needle with four side holes was prominently visualized and gained a significantly higher score (compared with the other needles in a phantom evaluation.

  12. Central Venous Catheters for Chemotherapy of Solid Tumors – Our Results in the Last 5 Years

    OpenAIRE

    Žganjer, Mirko; Čizmić, Ante; Butković, Diana; MATOLIĆ, MARTINA; Karaman-Ilić, Maja; Stepan, Jasminka

    2008-01-01

    Central venous catheters provide an easy access for intravenous medications. Having a central line in place will relieve a child from the discomfort and danger of multiple regular intravenous lines for chemotherapy. The use of indwelling central venous catheters has become commonplace in the management of children undergoing oncological treatment. There are two types of central lines commonly used. There are Broviac catheters and Port-A-Cath (PAC) catheters. In the last 5 years we...

  13. Colonization of bacteria on polyvinyl chloride and Teflon intravascular catheters in hospitalized patients.

    OpenAIRE

    Sheth, N. K.; Franson, T R; Rose, H. D.; Buckmire, F L; Cooper, J. A., Jr.; Sohnle, P G

    1983-01-01

    During an 8-month period all intravascular catheters were removed by sterile technique upon completion of use and submitted to the hospital microbiology laboratory. All catheters were routinely cultured by the semiquantitative culture technique, with greater than or equal to 15 colonies being defined as a positive result. Of the 687 Teflon catheters cultured, 6.9% were positive by culture, compared with 24.6% of 77 polyvinyl chloride catheters (P less than 0.001). Also, colonization of coagul...

  14. Experimental study of needle-tissue interaction forces: effect of needle geometries, insertion methods and tissue characteristics.

    Science.gov (United States)

    Jiang, Shan; Li, Pan; Yu, Yan; Liu, Jun; Yang, Zhiyong

    2014-10-17

    A thorough understanding of needle-tissue interaction mechanics is necessary to optimize needle design, achieve robotically needle steering, and establish surgical simulation system. It is obvious that the interaction is influenced by numerous variable parameters, which are divided into three categories: needle geometries, insertion methods, and tissue characteristics. A series of experiments are performed to explore the effect of influence factors (material samples n=5 for each factor) on the insertion force. Data were collected from different biological tissues and a special tissue-equivalent phantom with similar mechanical properties, using a 1-DOF mechanical testing system instrumented with a 6-DOF force/torque (F/T) sensor. The experimental results indicate that three basic phases (deformation, insertion, and extraction phase) are existent during needle penetration. Needle diameter (0.7-3.2mm), needle tip (blunt, diamond, conical, and beveled) and bevel angle (10-85°) are turned out to have a great influence on insertion force, so do the insertion velocity (0.5-10mm/s), drive mode (robot-assisted and hand-held), and the insertion process (interrupted and continuous). Different tissues such as skin, muscle, fat, liver capsule and vessel are proved to generate various force cures, which can contribute to the judgement of the needle position and provide efficient insertion strategy. PMID:25169657

  15. Review of Synthetic Methods to Form Hollow Polymer Nanocapsules

    Energy Technology Data Exchange (ETDEWEB)

    Barker, Madeline T. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-03-13

    Syntactic foams have grown in interest due to the widened range of applications because of their mechanical strength and high damage tolerance. In the past, hollow glass or ceramic particles were used to create the pores. This paper reviews literature focused on the controlled synthesis of hollow polymer spheres with diameters ranging from 100 –200 nm. By using hollow polymer spheres, syntactic foams could reach ultra-low densities.

  16. Fabrication of Closed Hollow Bulb Obturator Using Thermoplastic Resin Material

    OpenAIRE

    Bidhan Shrestha; E. Richard Hughes; Raj Kumar Singh; Pramita Suwal; Prakash Kumar Parajuli; Pragya Shrestha; Arati Sharma; Galav Adhikari

    2015-01-01

    Purpose. Closed hollow bulb obturators are used for the rehabilitation of postmaxillectomy patients. However, the time consuming process, complexity of fabrication, water leakage, and discoloration are notable disadvantages of this technique. This paper describes a clinical report of fabricating closed hollow bulb obturator using a single flask and one time processing method for an acquired maxillary defect. Hard thermoplastic resin sheet has been used for the fabrication of hollow bulb part ...

  17. Preparation and Characterization of Hollow Spheres of Rutile

    OpenAIRE

    Eiden, Stefanie; Maret, Georg

    2002-01-01

    Hollow spherical particles of rutile were obtained by coating colloidal polystyrene beads with a titanium oxide hydrate layer and subsequently calcining at elevated temperatures under an oxygen atmosphere. In order to investigate the optimum conditions for the preparation of these hollow beads the maximum temperature and heating rate were systematically varied. The dimensions of the voids and the shell thickness of the hollow beads can be tailored by the size of the polystyrene beads and the ...

  18. Improving solid to hollow core transmission for integrated ARROW waveguides

    OpenAIRE

    Lunt, Evan J.; Measor, Philip; Phillips, Brian S.; Kühn, Sergei; Schmidt, Holger; Hawkins, Aaron R.

    2008-01-01

    Optical sensing platforms based on anti-resonant reflecting optical waveguides (ARROWs) with hollow cores have been used for bioanalysis and atomic spectroscopy. These integrated platforms require that hollow waveguides interface with standard solid waveguides on the substrate to couple light into and out of test media. Previous designs required light at these interfaces to pass through the anti-resonant layers. We present a new ARROW design which coats the top and sides of the hollow core wi...

  19. Hollow sphere, a flexible multimode Gravitational Wave antenna

    OpenAIRE

    Lobo, J. Alberto

    2001-01-01

    Hollow spheres have the same theoretical capabilities as the usual solid ones, since they share identical symmetries. The hollow sphere is however more flexible, as thickness is an additional parameter one can vary to approach given specifications. I will briefly discuss the more relevant properties of the hollow sphere as a GW detector (frequencies, cross sections), and suggest some scenarios where it can generate significant astrophysical information.

  20. 21 CFR 878.4200 - Introduction/drainage catheter and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Introduction/drainage catheter and accessories. 878.4200 Section 878.4200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Introduction/drainage catheter and accessories. (a) Identification. An introduction/drainage catheter is...

  1. Numerical simulation of the pulsating catheter pump : A left ventricular assist device

    NARCIS (Netherlands)

    Verkerke, GJ; Mihaylov, D; Geertsema, AA; Lubbers, J; Rakhorst, G

    1999-01-01

    The pulsating catheter (PUCA) pump, a left ventricular assist device, consists of a hydraulically or pneumatically driven membrane pump, extracorporeally placed and mounted to a valved catheter. The catheter is introduced into an easily accessible artery and positioned with its distal tip in the lef

  2. Transcatheter Removal of Embolized Port Catheters from the Hearts of Two Children

    Directory of Open Access Journals (Sweden)

    Osman Baspinar

    2015-01-01

    Full Text Available Embolization of a port catheter is a dangerous and serious complication. In this paper, we present two cases of children, aged 4.5 months and 6 years, in whom port catheters had embolized to the right ventricle one month and 1.5 years priorly, respectively; the port catheters were retrieved via snaring.

  3. Use of an alteplase algorithm for the management of hemodialysis catheter dysfunction.

    Science.gov (United States)

    Abdelmoneim, Ahmed S; Miller, Lisa M; Armstrong, Sean; Sood, Manish M; Wazny, Lori; Chateau, Dan; Vercaigne, Lavern M

    2012-04-01

    Hemodialysis (HD) catheter dysfunction compromises HD adequacy and increases the cost of patient care. Repeated administration of alteplase in HD catheters typically produces only short-term benefits. The purpose of this study was to design, implement, and evaluate the efficacy of an experimental alteplase algorithm to manage HD catheter dysfunction. This was a two-part prospective nonrandomized study. Baseline data of alteplase use and catheter exchange were collected during part 1 of the study. Part 2 consisted of the alteplase algorithm implementation and repeat collection of catheter data. Rates of alteplase use and catheter exchange per 1000 catheter-days were the primary and secondary outcomes of the study. One hundred and seventy-two catheters in 131 patients were followed prospectively during the course of the study. The adjusted relative rate (RR) of alteplase use showed no significant difference between both parts of the study, adjusted RR: 1.10, 95% confidence interval (CI) (0.73-1.65). Similarly, catheter exchange rates were not significantly different over the duration of the study (1.12 vs. 1.03 per 1000 catheter-days). However, waiting time for catheter exchange increased from 20.36 ± 14 days in part 1 to 38.42 ± 28 days in part 2 (P < 0.05). The alteplase algorithm did not significantly reduce alteplase use. This may be partially explained by repeated use of alteplase in part 2, due to longer waiting times for catheter exchange procedures. PMID:22098698

  4. Biofilm formation in long-term central venous catheters in children with cancer

    DEFF Research Database (Denmark)

    Handrup, Mette Møller; Fuursted, Kurt; Funch, Peter;

    2012-01-01

    Taurolidine has demonstrated inhibition of biofilm formation in vitro. The aim of this study was to compare the effect of catheter locking with taurolidine vs heparin in biofilm formation in central venous catheters. Forty-eight children with cancer were randomized to catheter locking by heparin ...

  5. Bilateral external iliac artery catheter-induced vasospasm during angiography--a case report.

    Science.gov (United States)

    Gallagher, Chris; Shanklin, Chris; Roonsritong, Chanwit; Halldorsson, Ari; Tsikouris, James; Meyerrose, Gary

    2006-01-01

    The occurrence of catheter-induced vasospasm of small-caliber arteries during cardiac angiography is well documented. In contrast, little documentation of catheter-induced vasospasm in large-caliber arteries exists. This case presents reproducible catheter-induced vasospasm with bilateral asymptomatic occlusion of the femoral and iliac arteries. PMID:16444466

  6. Placing of tunneled central venous catheters prior to induction chemotherapy in children with acute lymphoblastic leukemia

    DEFF Research Database (Denmark)

    Handrup, Mette Møller; Møller, Jens Kjølseth; Frydenberg, Morten;

    2010-01-01

    BACKGROUND: Tunneled central venous catheters (CVCs) are inevitable in children with acute lymphoid leukemia (ALL). The aim of this study was to evaluate the risk of CVC-related complications in children with ALL in relation to timing of catheter placement and type of catheter. PROCEDURE: All...

  7. Manufacturing hollow obturator with resilient denture liner on post hemimaxillectomy

    Directory of Open Access Journals (Sweden)

    Michael Josef Kridanto Kamadjaja

    2006-03-01

    Full Text Available A resilient denture liner is placed in the part of the hollow obturator base that contacts to post hemimaxillectomy mucosa. Replacing the resilient denture liner can makes the hollow obturator has an intimate contact with the mucosa, so it can prevents the mouth liquid enter to the cavum nasi and sinus, also eliminates painful because of using the hollow obturator. Resilient denture liner is a soft and resilient material that applied to the fitting surface of a denture in order to allow a more distribution of load. A case was reported about using the hollow obturator with resilient denture liner on post hemimaxillectomy to overcome these problems.

  8. Transurethral microwave needle ablation for bladder cancer

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    @@To investigate the role of transurethral microwave needle ablation (TUMWNA) in the management of bladder cancer,TUMWNA was carried out in 24 patients with bladder cancer since 1989. From January 1989 to December 1997, 24 patients with bladder cancer were treated with TUMWNA. The 15 men and 9 women were 42 to 67 years old (mean, 58). There were 18 cases with a single tumor and 6 with multiple tumors (4 with 2 tumors, 1 with 3 and 1 with 4). Tumor diameter ranged from 0.3 to 2.5 cm. The lesions grew in different bladder regions: 13 tumors arose from the fundus, 3 tumors from the dome, 9 from the lateral wall, 5 from the anterior wall, 1 from the triangle region and 2 tumors were situated in the obturator nerve reflex sensitive region.

  9. Can elastography replace fine needle aspiration?

    DEFF Research Database (Denmark)

    Popescu, Alexandru; Săftoiu, Adrian

    2014-01-01

    Endoscopic ultrasound (EUS) is one of the best diagnostic methods for diseases of the digestive tract and surrounding organs. Whereas EUS-guided fine needle aspiration (FNA) has been very useful for providing histological confirmation for previously hard to reach lesions, elastography is aiming to...... obtain a "virtual biopsy" by assessing differences in elasticity between the normal and pathological - usually malignant - tissue. A question that arises is whether EUS-elastography has reached a stage where it might successfully supplant the use of EUS-FNA in some of its clinical indications. The main...... improve the accuracy of non-invasive EUS assessment, possibly making the case for a more limited or targeted use of EUS-FNA in selected cases....

  10. Pulmonary actinomycosis in fine needle aspiration cytology

    Directory of Open Access Journals (Sweden)

    Patel Keyuri

    2009-01-01

    Full Text Available Pulmonary actinomycosis is a rare bacterial lung disease caused by one of two types of bacteria, Actinomyces or Propioni. Pulmonary actinomycosis in the lung causes lung cavities, lung nodules, and pleural effusion. We report here a case of pulmonary actinomycosis that was diagnosed by fine needle aspiration cytology (FNAC. A 45 year-old male with a history of smoking and alcohol abuse, presented with complaints of cough with hemoptysis, right-sided chest pain, and fever of two months′ duration. A chest radiograph and computed tomography (CT of the thorax showed a right upper lobe mass lesion with hilar lymphadenopathy. CT-guided FNAC revealed colonies of Actinomyces surrounded by polymorphs. The disease is commonly confused with other chronic suppurative lung diseases and malignancy. An early diagnosis by FNAC prevents difficulties in the management of the disease, as well as considerable physiological and physical morbidity, including unwarranted surgery.

  11. Preparation of TiO2 hollow fibers using poly(vinylidene fluoride) hollow fiber microfiltration membrane as a template

    International Nuclear Information System (INIS)

    TiO2 hollow fibers were successfully prepared by using poly(vinylidene fluoride) hollow fiber microfiltration membrane as a template. The preparation procedure includes repeated impregnation of the TiO2 precursor in the pores of the polymeric membrane, and calcination to burn off the template, producing the TiO2 hollow fibers. The TiO2 hollow fibers were characterized by X-ray diffraction (XRD) and scanning electron microscopy (SEM). TiO2 hollow fibers with other structures, such as honeycomb monolith and spring, were also prepared by preshaping the polymeric membranes into the honeycomb structure and spring, respectively. The phase structure of the TiO2 hollow fibers could be readily adjusted by changing the calcination temperature

  12. Transcervical Foley's catheter: a promising option for induction of labour

    Directory of Open Access Journals (Sweden)

    Divya Pandey

    2015-06-01

    Full Text Available We hereby report the results of a small randomized prospective study where we compared the efficiency and efficacy of transcervical extra-amniotic Foley catheter placement to intravaginal dinoprostone gel as a method of induction of labour. [Int J Reprod Contracept Obstet Gynecol 2015; 4(3.000: 933-933

  13. Pneumothorax as a complication of central venous catheter insertion.

    Science.gov (United States)

    Tsotsolis, Nikolaos; Tsirgogianni, Katerina; Kioumis, Ioannis; Pitsiou, Georgia; Baka, Sofia; Papaiwannou, Antonis; Karavergou, Anastasia; Rapti, Aggeliki; Trakada, Georgia; Katsikogiannis, Nikolaos; Tsakiridis, Kosmas; Karapantzos, Ilias; Karapantzou, Chrysanthi; Barbetakis, Nikos; Zissimopoulos, Athanasios; Kuhajda, Ivan; Andjelkovic, Dejan; Zarogoulidis, Konstantinos; Zarogoulidis, Paul

    2015-03-01

    The central venous catheter (CVC) is a catheter placed into a large vein in the neck [internal jugular vein (IJV)], chest (subclavian vein or axillary vein) or groin (femoral vein). There are several situations that require the insertion of a CVC mainly to administer medications or fluids, obtain blood tests (specifically the "central venous oxygen saturation"), and measure central venous pressure. CVC usually remain in place for a longer period of time than other venous access devices. There are situations according to the drug administration or length of stay of the catheter that specific systems are indicated such as; a Hickman line, a peripherally inserted central catheter (PICC) line or a Port-a-Cath may be considered because of their smaller infection risk. Sterile technique is highly important here, as a line may serve as a port of entry for pathogenic organisms, and the line itself may become infected with organisms such as Staphylococcus aureus and coagulase-negative Staphylococci. In the current review we will present the complication of pneumothorax after CVC insertion. PMID:25815301

  14. Abnormal location of umbilical venous catheter due to Scimitar syndrome

    International Nuclear Information System (INIS)

    Scimitar syndrome is a rare congenital anomaly where the right pulmonary veins return to the inferior vena cava (IVC) just below the diaphragm. On chest X-ray (CXR), an IVC catheter will be in a bizarre location outside the heart if it inadvertently passes into the scimitar vein rather than into the right atrium

  15. Peritoneo-vulvar catheter extrusion after shunt operation.

    Science.gov (United States)

    Nagulic, M; Djordjevic, M; Samardzic, M

    1996-04-01

    We report an unusual case of catheter extrusion through the external genitalia. between the labium majus and the labium minus, in a 6-month-old hydrocephalic baby. The event occurred 5 months after placement of a ventriculoperitoneal shunt. PMID:8739410

  16. Optimizing safety and efficacy of catheter ablation procedures

    NARCIS (Netherlands)

    F. Akca (Ferdi)

    2015-01-01

    markdownabstractAbstract In this thesis new developments in the field of invasive electrophysiology are studied and discussed. The aim of this work is to find strategies to optimize safety and efficacy of catheter ablation procedures. The most important developments that are studied in this thesis

  17. Polyvinyl chloride catheters with repressed migration of plasticizers

    Czech Academy of Sciences Publication Activity Database

    Sedláček, T.; Polášková, M.; Kašpárková, V.; Filip, Petr; Sáha, P.

    Larnaca : Polymer Processing Society, 2009, s. 243. [Polymer Processing Society Europe/Africa Regional Meeting. Larnaca (GR), 18.10.2009-21.10.2009] Institutional research plan: CEZ:AV0Z20600510 Keywords : Polyvinyl chloride * catheter * repressed migration of plasticizers Subject RIV: BK - Fluid Dynamics

  18. 21 CFR 876.5130 - Urological catheter and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Urological catheter and accessories. 876.5130 Section 876.5130 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5130...

  19. Percutaneous placement of peritoneal port-catheter in oncologic patients

    International Nuclear Information System (INIS)

    The aim of this paper is to describe the technique of percutaneous ultrasound (US)-guided placement of a peritoneal port-catheter in an interventional radiological setting. Nineteen patients with peritoneal carcinomatosis were selected for intraperitoneal port-catheter placement in order to perform intracavitary receptor-immuno- or radio-immunotherapy with Ytrium-90. All the procedures were performed percutaneously under US and fluoro guidance; the insertion site for catheters was chosen according to abdominal conditions and US findings: all devices were implanted at the lower abdominal quadrants. All patients were followed up with CT and US according to the therapy protocol. The procedure was successfully completed in 15/19 patients, in 4 being contraindicated by peritoneal adhesions. No procedure-related complications and device occlusions during therapy were observed; one catheter displaced 7 months later the placement. In our experience, this procedure was feasible, reliable and easy to perform, allowing the correct administration of the planned intracavitary therapy. Peritoneal adhesions are the main limitation of peritoneal port placement. (orig.)

  20. Minimizing Hemodialysis Catheter Dysfunction: An Ounce of Prevention

    Directory of Open Access Journals (Sweden)

    Timmy Lee

    2012-01-01

    Full Text Available The maintenance of tunneled catheter (TC patency is critical for the provision of adequate hemodialysis in patients who are TC-dependent. TC dysfunction results in the need for costly and inconvenient interventions, and reduced quality of life. Since the introduction of TCs in the late 1980s, heparin catheter lock has been the standard prophylactic regimen for the prevention of TC dysfunction. More recently, alternative catheter locking agents have emerged, and in some cases have shown to be superior to heparin lock with respect to improving TC patency and reducing TC-associated infections. These include citrate, tissue plasminogen activator, and a novel agent containing sodium citrate, methylene blue, methylparaben, and propylparaben. In addition, prophylaxis using oral anticoagulants/antiplatelet agents, including warfarin, aspirin, ticlodipine, as well as the use of modified heparin-coated catheters have also been studied for the prevention of TC dysfunction with variable results. The use of oral anticoagulants and/or antiplatelet agents as primary or secondary prevention of TC dysfunction must be weighed against their potential adverse effects, and should be individualized for each patient.

  1. Management of complicated perspired pleural, by means of angiographic catheters

    International Nuclear Information System (INIS)

    Based on the recent literature and to demonstrate that complicated exudate drainage through angiographic catheters is a safe and efficient technique that offers a very useful alternative as a first choice treatment and also as a secondary treatment in the cases where thoracotomy tubes have failed, we have designed this scheme, in 28 patients with pleural effusion by radiographic evidence with a 52.7 average age and that fulfilled the light criteria for complicated pleural effusions, we accomplished drainage of the pleural effusion, using angiographic catheters, under ultrasound guidance. In the drainages that were realized, there was an 85.72% rate of success. it is important to mention that of the remaining 14.28% that presented pleural fluid after the drainage, none required surgery. 71.42% of the patients were treated only with angiographic catheters, while the remaining 28.57% were treated with them, after a failed drainage with thoracotomy tubes. The necessary time for the drainage was between 3 and 14 days. There were no complications during the catheter placement procedure neither during the time required for drainage of the pleural effusion

  2. Should a Double-Lumen Catheter be withdrawn?

    Directory of Open Access Journals (Sweden)

    Samad Shams Vahdati

    2011-08-01

    Full Text Available Introduction: Haemodialysis needs a credible and recurrent access to the systemic circula-tion which can be accomplished by way of central vein catheterization. We report the case of bleeding after withdrawal of the double lumen catheter. Case Presentation: A 36-year-old woman who was a known case of end-stage renal disease referred to a dialysis center because of her arteriovenous fistula malfunction. A double-lumen catheter was inserted via the right internal jugular vein but failed to become functional so in the emergency department we decided to withdrawal catheter under cardiac monitoring and pulse oximetry but unfortunately A few minutes after the withdrawal of the double lumen Catheter the patient became agitated and confused. The resuscitation team after infusing IV fluid and blood decided to emergent thoracotomy. We control bleeding by direct pressure and repaired a rupture of the posterior aspect of the right internal jugular and right subclavian vein junction. Six hours later she became alert and one week after discharged, she was in well general condition.

  3. Skin Blood Perfusion and Cellular Response to Insertion of Insulin Pen Needles With Different Diameters

    DEFF Research Database (Denmark)

    Præstmark, Kezia Ann; Stallknecht, Bente Merete; Bo Jensen, Casper;

    2014-01-01

    there was a trend of an increased response with increasing needle diameter. Skin blood perfusion response to pen needle insertions rank according to needle diameter, and the tissue response caused by hooked 32G needles corresponds to that of 28G needles. The relation between needle diameter and trauma...... skin blood perfusion response around needle insertion sites. Three common sized pen needles of 28G, 30G, and 32G as well as hooked 32G needles, were inserted into the neck skin of pigs and then removed. Laser Speckle Contrast Analysis was used to measure skin blood perfusion for 20 minutes after the...... insertions. Seven pigs were included in the study and a total of 118 randomized needle insertions were conducted. Histology was made of tissue samples inserted with 18G, 28G, and 32G needles, and stained to quantify red and white blood cell response. Based on area under curve, calculated for each individual...

  4. Facile Fabrication of Ultrafine Hollow Silica and Magnetic Hollow Silica Nanoparticles by a Dual-Templating Approach

    OpenAIRE

    Xiao Xiangheng; Zhang Shaofeng; Peng Tangchao; Ren Feng; Fan Lixia; Wu Wei; Jiang Changzhong

    2009-01-01

    Abstract The development of synthetic process for hollow silica materials is an issue of considerable topical interest. While a number of chemical routes are available and are extensively used, the diameter of hollow silica often large than 50 nm. Here, we report on a facial route to synthesis ultrafine hollow silica nanoparticles (the diameter of ca. 24 nm) with high surface area by using cetyltrimethylammmonium bromide (CTAB) and sodium bis(2-ethylhexyl) sulfosuccinate (AOT) as co-templates...

  5. Effect of impeller design and spacing on gas exchange in a percutaneous respiratory assist catheter.

    Science.gov (United States)

    Jeffries, R Garrett; Frankowski, Brian J; Burgreen, Greg W; Federspiel, William J

    2014-12-01

    Providing partial respiratory assistance by removing carbon dioxide (CO2 ) can improve clinical outcomes in patients suffering from acute exacerbations of chronic obstructive pulmonary disease and acute respiratory distress syndrome. An intravenous respiratory assist device with a small (25 Fr) insertion diameter eliminates the complexity and potential complications associated with external blood circuitry and can be inserted by nonspecialized surgeons. The impeller percutaneous respiratory assist catheter (IPRAC) is a highly efficient CO2 removal device for percutaneous insertion to the vena cava via the right jugular or right femoral vein that utilizes an array of impellers rotating within a hollow-fiber membrane bundle to enhance gas exchange. The objective of this study was to evaluate the effects of new impeller designs and impeller spacing on gas exchange in the IPRAC using computational fluid dynamics (CFD) and in vitro deionized water gas exchange testing. A CFD gas exchange and flow model was developed to guide a progressive impeller design process. Six impeller blade geometries were designed and tested in vitro in an IPRAC device with 2- or 10-mm axial spacing and varying numbers of blades (2-5). The maximum CO2 removal efficiency (exchange per unit surface area) achieved was 573 ± 8 mL/min/m(2) (40.1 mL/min absolute). The gas exchange rate was found to be largely independent of blade design and number of blades for the impellers tested but increased significantly (5-10%) with reduced axial spacing allowing for additional shaft impellers (23 vs. 14). CFD gas exchange predictions were within 2-13% of experimental values and accurately predicted the relative improvement with impellers at 2- versus 10-mm axial spacing. The ability of CFD simulation to accurately forecast the effects of influential design parameters suggests it can be used to identify impeller traits that profoundly affect facilitated gas exchange. PMID:24749994

  6. Staphylococcus-Infected Tunneled Dialysis Catheters: Is Over-the-Wire Exchange an Appropriate Management Option?

    International Nuclear Information System (INIS)

    Purpose: Over-the-wire exchange of tunneled dialysis catheters is the standard of care per K/DOQI guidelines for treating catheter-related bacteremia. However, Gram-positive bacteremia, specifically with staphylococcus species, may compromise over-the-wire exchange due to certain biological properties. This study addressed the effectiveness of over-the-wire exchange of staphylococcus-infected tunneled dialysis catheters compared with non-staphylococcus-infected tunneled dialysis catheters. Methods: Patients who received over-the-wire exchange of their tunneled dialysis catheter due to documented or suspected bacteremia were identified from a QA database. Study patients (n = 61) had positive cultures for Staphylococcus aureus, Staphylococcus epidermidis, or coagulase-negative staphylococcus not otherwise specified. Control patients (n = 35) received over-the-wire exchange of their tunneled dialysis catheter due to infection with any organism besides staphylococcus. Overall catheter survival and catheter survival among staphylococcal species were assessed. Results: There was no difference in tunneled dialysis catheter survival between study and control groups (P = 0.46). Median survival time was 96 days for study catheters and 51 days for controls; survival curves were closely superimposed. There also was no difference among the three staphylococcal groups in terms of catheter survival (P = 0.31). The median time until catheter removal was 143 days for SE, 67 days for CNS, and 88 days for SA-infected catheters. Conclusions: There is no significant difference in tunneled dialysis catheter survival between over-the-wire exchange of staphylococcus-infected tunneled dialysis catheters and those infected with other organisms.

  7. In vivo Monitoring of Serotonin by Nanomaterial Functionalized Acupuncture Needle

    Science.gov (United States)

    Li, Yu-Tao; Tang, Li-Na; Ning, Yong; Shu, Qing; Liang, Feng-Xia; Wang, Hua; Zhang, Guo-Jun

    2016-06-01

    Acupuncture treatment is amazing but controversial. Up to now, the mechanism of treating diseases by acupuncture and moxibustion is still unclear, especially the occurrence of the molecular events in local acupoints. Herein, we report an extremely stable microsensor by modifying carbon nanotube (CNT) to the tip surface of acupuncture needle and applying this CNT-modified acupuncture needle for real time monitoring of serotonin (5-HT) in vivo. To stabilize CNT modification on the needle tip surface, poly(3,4-ethylenedioxythiophene)(PEDOT) was employed as glue water to stick CNT on the needle. The detection limit of the CNT-modified needle was found to be approximately 50 nM and 78 nM in the PBS and the cell medium, respectively. In addition, the needle showed good selectivity to some inflammatory mediators and some electroactive molecules. For the first time, the CNT-modified needle could be directly probed into rat body for real time monitoring of 5-HT in vivo, showing a great potential for better understanding the mechanism of acupuncture treatment.

  8. Hypochlorite (1% is inefficient in decontaminating blood containing hypodermic needles

    Directory of Open Access Journals (Sweden)

    Chitnis V

    2002-01-01

    Full Text Available Infectious biomedical waste and sharps have a potential hazard of transmission of pathogens. Among sharps, used needles form a major share and disinfection by 1 % hypochlorite is recommended in biomedical waste management rules of India. The aim of the present study was to evaluate the efficacy of hypochlorite for the decontamination of needles. Needles (16 g filled with suspensions of standard strains and clinical isolates of gram positive and gram negative bacteria in plain normal saline and in human blood containing anticoagulant, were exposed to 1% hypochlorite and the surviving bacteria were subjected to viable counts. The observations indicated that 85 - 90 % of the needles filled with bacterial suspensions in saline are disinfected to a level of >5 log bacterial reduction (standard disinfection on exposure to hypochlorite but only 15 to 30% needles contaminated with the challenge bacteria suspended in blood showed >5 log reduction in viable counts. Thus, hypochlorite treatment is inadequate for disinfecting needles contaminated with pathogenic bacteria in presence of blood and should not be recommended as an option for disinfection of the needles.

  9. Modulation of crystalline Proteus mirabilis biofilm development on urinary catheters.

    Science.gov (United States)

    Stickler, David J; Morgan, Sheridan D

    2006-05-01

    The crystalline biofilms formed by Proteus mirabilis can seriously complicate the care of patients undergoing long-term bladder catheterization. The generation of alkaline urine by the bacterial urease causes calcium and magnesium phosphates to precipitate from urine and accumulate in the catheter biofilm, blocking the flow of urine from the bladder. The pH at which these salts crystallize from a urine sample, the nucleation pH (pH(n)), can be elevated by diluting the urine and by increasing its citrate content. The aim of this study was to examine whether manipulation of pH(n) in these ways modulated the rate at which crystalline biofilm developed. Experiments in laboratory models of the catheterized bladder infected with P. mirabilis showed that when the bladder was supplied with a concentrated urine (pH(n) 6.7) at a low fluid output (720 ml per 24 h), catheters blocked at 19-31 h. Diluting this urine 1:4 increased the pH(n) to 7.5 and models supplied with this urine at 2880 ml per 24 h took 110-137 h to block. When models were supplied with urine containing citrate at 1.5 mg ml(-1) or above (pH(n) 8.3-9.1), the catheters drained freely for the full 7 day experimental period. Scanning electron microscopy revealed that the catheter biofilms that developed in urine with high pH(n) values were devoid of crystalline formations. These observations should encourage a clinical trial to examine the effect of increasing a patient's fluid intake with citrate-containing drinks on the encrustation and blockage of catheters. PMID:16585633

  10. Comparison of a new aspiration needle device and the Quick-Core biopsy needle for transjugular liver biopsy

    Institute of Scientific and Technical Information of China (English)

    Toru Ishikawa; Tomoteru Kamimura; Hiroteru Kamimura; Atsunori Tsuchiya; Tadayuki Togashi; Kouji Watanabe; Kei-ichi Seki; Hironobu Ohta; Toshiaki Yoshida; Noriko Ishihara

    2006-01-01

    AIM: To evaluate sample adequacy, safety, and needle passes of a new biopsy needle device compared to the Quick-Core biopsy needle for transjugular liver biopsy in patients affected by liver disease.METHODS: Thirty consecutive liver-disease patients who had major coagulation abnormalities and/or relevant ascites underwent transjugular liver biopsy using either a new needle device (18 patients) or the Quick-Core biopsy needle (12 patients). The length of the specimens was measured before fixation. A pathologist reviewed the histological slides for sample adequacy and pathologic diagnoses. The two methods' specimen adequacy and complication rates were assessed.RESULTS: Liver biopsies were technically successful in all 30 (100%) patients, with diagnostic histological core specimens obtained in 30 of 30 (100%) patients, for an overall success rate of 100%. With the new device,18 specimens were obtained, with an average of 1.1passes per patient. Using the Quick-Core biopsy needle,12 specimens were obtained, with an average of 1.8passes per patient. Specimen length was significantly longer with the new needle device than with the QuickCore biopsy needle (P < 0.05). The biopsy tissue was not fragmented in any of the specimens with the new aspiration needle device, but tissue was fragmented in 3 of 12 (25.0%) specimens obtained using the Quick-Core biopsy needle. Complications included cardiac arrhythmia in 3 (10.0%) patients, and transient abdominal pain in 4 (13.3%) patients. There were no cases of subcapsular hematoma, hemoperitoneum, or sepsis, and there was no death secondary to the procedure. In particular, no early or delayed major procedure-related complications were observed in any patient.CONCLUSION: Transjugular liver biopsy is a safe and effective procedure, and there was significant difference in the adequacy of the specimens obtained using the new needle device compared to the QuickCore biopsy needle. Using the new biopsy needle device,the specimens showed

  11. Catheter selection for ablation of the cavotricuspid isthmus for treatment of typical atrial flutter.

    Science.gov (United States)

    Da Costa, Antoine; Jamon, Yann; Romeyer-Bouchard, Cécile; Thévenin, Jérôme; Messier, Marc; Isaaz, Karl

    2006-11-01

    Radiofrequency catheter ablation (RFA) represents the first line therapy of the cavotricuspid isthmus-dependent atrial flutter (CTI-AFL) with a high efficacy and low secondary effects. RFA of CTI-dependent AFL can be performed by using various types of ablation catheters. Recent evaluations comparing externally cooled tip RFA (ecRFA) catheters and large-tip (8 mm) catheters have revealed that these catheters have a higher efficacy for CTI-AFL ablation compared to 4-mm catheters. The reliability of RFA catheters for AFL is variable and an optimal catheter selection may enhance the RFA effectiveness. The main goal of this article is to review the elements that improve the management of CTI RFA. Preliminary examinations of histopathologic and anatomical elements that may interfere with conventional CTI RFA are presented. Experimental studies concerning the electrobiology of large-tip and cooled-tip catheters are compared. The different catheter designs between cooled-tip and 8-mm-tip catheters are examined (size of the deflectable curve, rotation stability, and size of the distal nonsteerable catheter part) because of their critical role in CTI RFA results. A thorough review of clinical trials of each catheter is presented, and comparison of both catheters in this clinical setting is analyzed. In addition, the role of CTI morphology on AFL RF duration is underlined such as the value of right atrial angiography as an adjunct tool for CTI RFA catheter selection. Based on randomized studies, 8-mm-tip catheters seem to be more effective for ablation in case of straight angiographic isthmus morphology. On the other hand, ecRFA catheters appear to be more effective in cases of complex CTI anatomy or difficult CTI RFA. To reduce X-ray exposition and RFA application time, few studies report that CTI angiographic evaluation before RFA allows a catheter selection based on both CTI morphology and length. Moreover, preliminary data of randomized studies showed that an

  12. Stabilization of a Percutaneously Implanted Port Catheter System for Hepatic Artery Chemotherapy Infusion

    International Nuclear Information System (INIS)

    A port catheter system for hepatic artery infusion chemotherapy was implanted percutaneously via the left subclavian artery in 41 patients for treatment of unresectable liver metastases. The catheter tip was inserted into the gastroduodenal artery (GDA), the end hole was occluded with a guidewire fragment, and a side-hole for infusion was positioned at the bifurcation of the proper hepatic artery and the GDA. The GDA was embolized with steel coils around the infusion catheter tip via a transfemoral catheter. This procedure is designed to reduce the incidence of hepatic artery occlusion and infusion catheter dislocation

  13. Stabilization of a percutaneously implanted port catheter system for hepatic artery chemotherapy infusion

    International Nuclear Information System (INIS)

    A port catheter system for hepatic artery infusion chemotherapy was implanted percutaneously via the left subclavian artery in 41 patients for treatment of unresectable liver metastases. The catheter tip was inserted into the gastroduodenal artery (GDA), the end hole was occluded with a guidewire fragment, and a side-hole for infusion was positioned at the bifurcation of the proper hepatic artery and the GDA. The GDA was embolized with steel coils around the infusion catheter tip via a transfemoral catheter. This procedure is designed to reduce the incidence of hepatic artery occlusion and infusion catheter dislocation.

  14. Efficacy of dicloxacillin-coated polyurethane catheters in preventing subcutaneous Staphylococcus aureus infection in mice.

    OpenAIRE

    Sherertz, R J; Forman, D M; Solomon, D D

    1989-01-01

    In a mouse model, dicloxacillin-coated polyurethane catheters or control (uncoated) catheters were placed subcutaneously and then Staphylococcus aureus was inoculated at the time of insertion, 24 or 48 h later. The in vivo half-life of the antibiotic was 11 to 16 h. When 10(5) CFU of S. aureus were inoculated at the time of catheter insertion, dicloxacillin-coated catheters kept the number of S. aureus removed from catheters by sonication below 10(2) CFU at 12, 24, 48, and 96 h after inoculat...

  15. Controlled trial of a continuous irrigation suction catheter vs conventional intermittent suction catheter in clearing bronchial secretions from ventilated patients.

    Science.gov (United States)

    Isea, J O; Poyant, D; O'Donnell, C; Faling, L J; Karlinsky, J; Celli, B R

    1993-04-01

    Continuous irrigation-suction catheter (Irri-cath) is a double-lumen device that allows for simultaneous saline solution infusion and aspiration. This system may theoretically be more effective than conventional dry intermittent suction due to its vortex principle. To test this hypothesis, we performed 200 suction maneuvers in 20 ventilated patients. Identically shaped catheters were used in a randomized sequence. For the same individual, we used equal instilled saline solution volume (40 ml), vacuum pressure (-180 cm H2O), and ventilatory parameters. Effectiveness of suction was determined by measuring the total aspirated volume, the dry lyophilized weight of secretion, the corrected dry weight (dry weight-weight of instilled salt), and protein concentration. No difference in heart rate, respiratory frequency, O2 saturation, systemic blood pressure, peak inspiratory pressure, or patient discomfort was found when the two modalities were compared; however, the total volume of secretions collected, the dry weight, the corrected dry weight, and the protein concentration were significantly higher with continuous irrigation suction catheter when compared with the conventional method (p < 0.05). The suction time was shorter with the Irri-cath (p < 0.05). We conclude that the Irri-Cath is more effective than conventional intermittent suction catheter in clearing bronchial secretions in patients on mechanical ventilation. PMID:8131470

  16. A New Flavonoid in Pine Needles of Cedrus deodara

    Institute of Scientific and Technical Information of China (English)

    LIU Dong-yan; SHI Xiao-feng; WANG Dong-dong; MA Qu-huan; ZHANG Jun-min; LI Chong

    2011-01-01

    Objective To study the chemical constituents of flavonoids in pine needles of Cedrus deodara.Methods Flavonoids were isolated and purified from ethyl acetate extract of pine needles by chromatography on silica gel and Sephadex LH-20.Their structures were identified on the basis of spectroscopic analysis and chemical evidence.Results Five flavonoids were isolated and purified.Their structures were identified as cedrusone A(1),myricetin(2),2R,3R-dihydromyricetin(3),quercctin(4),and 2R,3R-dihydroquercetin(5).Conclusion Compound 1 is a new compound.Compounds 2-5 are isolated from pine needles of this genus for the first time.

  17. Diagenesis of conifer needles in a coastal marine environment

    Science.gov (United States)

    Hedges, John I.; Weliky, K.

    1989-10-01

    Physically intact fir, hemlock and cedar needles were isolated from different horizons of a sediment core from a coastal marine bay (Dabob Bay, Washington State, U.S.A.) and from nearby trees and forest litter. Green fir, hemlock and cedar needles were all characterized by glucose-rich aldose mixtures (~30% of tissue carbon), the production of vanillyl and cinnamyl CuO-derived phenols (~8% of tissue carbon) and the presence of both pinitol and myo-inositol (1-2% of tissue carbon). Needles from forest litter were enriched in lignin phenols and non-glucose aldoses and depleted in glucose and cyclitols. The sediment core contained an average of 10 mg/1 of physically intact fir, hemlock and cedar needles, which occurred in similar relative abundances and accounted for less than 1% of the total nonwoody gymnosperm tissue. Compared to the green and litter counterparts, all sedimentary needles were greatly depleted in cyclitols, glucose and p-coumaric acid and enriched in vanillyl phenol precursors. The degree of elevation of vanillyl phenol yield from the degraded needles was used to estimate minimal carbon losses from the samples, which ranged from near 40% for needle litter to almost 70% for the deepest (~100 years old) sedimentary fir/hemlock samples. Although downcore increases in carbon loss and refractory organic components indicated in situ diagenesis, the bulk of overall degradation occurred either on land or during the first 10-20 years after deposition. Atomic C/N ratios of degraded needles were lower than for green counterparts, but nitrogen was lost overall. These relative changes indicate the following stability series: vanillyl phenols > N > ferulic acid, p-hydroxy phenols, most aldoses and bulk tissue > glucose and p-coumaric acid > cyclitols (near 100% loss). Vanillic acid to vanillin ratios, (Ad/Al)v, of the green fir and hemlock needles were unusually high (0.36-0.38) and decreased downcore. Diagenesis also decreased the cinnamyl/vanillyl phenol ratio

  18. On the use of hypodermic needles in electrospray

    Directory of Open Access Journals (Sweden)

    Gañán-Calvo A.M.

    2013-04-01

    Full Text Available We present an experimental analysis of electrospray where the standard feeding capillary was re- placed with a hypodermic needle. Both the current intensity and the jet diameter were measured for a variety of leaky-dielectric liquids. The results obtained with a feeding capillary and a hypodermic needle of similar dimen- sions were compared. An increase of the liquid conductivity was measured by assuming that the electric current obeys the same scaling law in both configurations. That increase was likely due to the electrochemical reaction taking place in the needle tip.

  19. Urinary catheter capable of repeated on-demand removal of infectious biofilms via active deformation.

    Science.gov (United States)

    Levering, Vrad; Cao, Changyong; Shivapooja, Phanindhar; Levinson, Howard; Zhao, Xuanhe; López, Gabriel P

    2016-01-01

    Biofilm removal from biomaterials is of fundamental importance, and is especially relevant when considering the problematic and deleterious impact of biofilm infections on the inner surfaces of urinary catheters. Catheter-associated urinary tract infections are the most common cause of hospital-acquired infections and there are over 30 million Foley urinary catheters used annually in the USA. In this paper, we present the design and optimization of urinary catheter prototypes capable of on-demand removal of biofilms from the inner luminal surface of catheters. The urinary catheters utilize 4 intra-wall inflation lumens that are pressure-actuated to generate region-selective strains in the elastomeric urine lumen, and thereby remove overlying biofilms. A combination of finite-element modeling and prototype fabrication was used to optimize the catheter design to generate greater than 30% strain in the majority of the luminal surface when subjected to pressure. The catheter prototypes are able to remove greater than 80% of a mixed community biofilm of Proteus mirabilis and Escherichia coli on-demand, and furthermore are able to remove the biofilm repeatedly. Additionally, experiments with the prototypes demonstrate that biofilm debonding can be achieved upon application of both tensile and compressive strains in the inner surface of the catheter. The fouling-release catheter offers the potential for a non-biologic, non-antibiotic method to remove biofilms and thereby for impacting the thus far intractable problem of catheter-associated infections. PMID:26584348

  20. Chlorhexidine Gluconate Dressings Reduce Bacterial Colonization Rates in Epidural and Peripheral Regional Catheters

    Directory of Open Access Journals (Sweden)

    Klaus Kerwat

    2015-01-01

    Full Text Available Introduction. Bacterial colonization of catheter tips is common in regional anesthesia and is a suspected risk factor for infectious complications. This is the first study evaluating the effect of CHG-impregnated dressings on bacterial colonization of regional anesthesia catheters in a routine clinical setting. Methods. In this prospective study, regional anesthesia catheter infection rates were examined in two groups of patients with epidural and peripheral regional catheters. In the first group, regional anesthesia was dressed with a conventional draping. The second group of patients underwent catheter dressing using a CHG-impregnated draping. Removed catheters and the insertion sites were both screened for bacterial colonization. Results. A total of 337 catheters from 308 patients were analysed. There was no significant reduction of local infections in either epidural or peripheral regional anesthesia catheters in both CHG and conventional groups. In the conventional group, 21% of the catheter tips and 41% of the insertion sites showed positive culture results. In the CHG-group, however, only 3% of the catheter tips and 8% of the insertion sites were colonised. Conclusion. CHG dressings significantly reduce bacterial colonization of the tip and the insertion site of epidural and peripheral regional catheters. However, no reductions in rates of local infections were seen.

  1. Co-Flow Hollow Cathode Technology

    Science.gov (United States)

    Hofer, Richard R.; Goebel, Dan M.

    2011-01-01

    Hall thrusters utilize identical hollow cathode technology as ion thrusters, yet must operate at much higher mass flow rates in order to efficiently couple to the bulk plasma discharge. Higher flow rates are necessary in order to provide enough neutral collisions to transport electrons across magnetic fields so that they can reach the discharge. This higher flow rate, however, has potential life-limiting implications for the operation of the cathode. A solution to the problem involves splitting the mass flow into the hollow cathode into two streams, the internal and external flows. The internal flow is fixed and set such that the neutral pressure in the cathode allows for a high utilization of the emitter surface area. The external flow is variable depending on the flow rate through the anode of the Hall thruster, but also has a minimum in order to suppress high-energy ion generation. In the co-flow hollow cathode, the cathode assembly is mounted on thruster centerline, inside the inner magnetic core of the thruster. An annular gas plenum is placed at the base of the cathode and propellant is fed throughout to produce an azimuthally symmetric flow of gas that evenly expands around the cathode keeper. This configuration maximizes propellant utilization and is not subject to erosion processes. External gas feeds have been considered in the past for ion thruster applications, but usually in the context of eliminating high energy ion production. This approach is adapted specifically for the Hall thruster and exploits the geometry of a Hall thruster to feed and focus the external flow without introducing significant new complexity to the thruster design.

  2. Hollow-Fiber Spacesuit Water Membrane Evaporator

    Science.gov (United States)

    Bue, Grant; Trevino, Luis; Tsioulos, Gus; Mitchell, Keith; Settles, Joseph

    2013-01-01

    The hollow-fiber spacesuit water membrane evaporator (HoFi SWME) is being developed to perform the thermal control function for advanced spacesuits and spacecraft to take advantage of recent advances in micropore membrane technology in providing a robust, heat-rejection device that is less sensitive to contamination than is the sublimator. After recent contamination tests, a commercial-off-the-shelf (COTS) micro porous hollow-fiber membrane was selected for prototype development as the most suitable candidate among commercial hollow-fiber evaporator alternatives. An innovative design that grouped the fiber layers into stacks, which were separated by small spaces and packaged into a cylindrical shape, was developed into a full-scale prototype for the spacesuit application. Vacuum chamber testing has been performed to characterize heat rejection as a function of inlet water temperature and water vapor back-pressure, and to show contamination resistance to the constituents expected to be found in potable water produced by the wastewater reclamation distillation processes. Other tests showed tolerance to freezing and suitability to reject heat in a Mars pressure environment. In summary, HoFi SWME is a lightweight, compact evaporator for heat rejection in the spacesuit that is robust, contamination- insensitive, freeze-tolerant, and able to reject the required heat of spacewalks in microgravity, lunar, and Martian environments. The HoFi is packaged to reject 810 W of heat through 800 hours of use in a vacuum environment, and 370 W in a Mars environment. The device also eliminates free gas and dissolved gas from the coolant loop.

  3. Hollow-Cathode Source Generates Plasma

    Science.gov (United States)

    Deininger, W. D.; Aston, G.; Pless, L. C.

    1989-01-01

    Device generates argon, krypton, or xenon plasma via thermionic emission and electrical discharge within hollow cathode and ejects plasma into surrounding vacuum. Goes from cold start up to full operation in less than 5 s after initial application of power. Exposed to moist air between operations without significant degradation of starting and running characteristics. Plasma generated by electrical discharge in cathode barrel sustained and aided by thermionic emission from emitter tube. Emitter tube does not depend on rare-earth oxides, making it vulnerable to contamination by exposure to atmosphere. Device modified for use as source of plasma in laboratory experiments or industrial processes.

  4. Preparation of spherical hollow alumina particles by thermal plasma

    International Nuclear Information System (INIS)

    Spherical hollow particles were prepared from solid alumina powders using DC arc thermal plasma, and then spray coating was performed with the as-prepared particles. Operating variables for the hollow particle preparation process were additional plasma gas, input power, and carrier gas flow rate. The spherical hollow alumina particles were produced in the case of using additive gas of H2 or N2, while alumina surface was hardly molten in the pure argon thermal plasma. In addition, the hollow particles were well produced in high power and low carrier gas conditions due to high melting point of alumina. Hollow structure was confirmed by focused ion beam-scanning electron microscopy analysis. Morphology and size distribution of the prepared particles that were examined by field emission-scanning electron microscopy and phase composition of the particles was characterized by X-ray diffraction. In the spray coating process, the as-prepared hollow particles showed higher deposition rate. - Highlights: ► Spherical hollow alumina powder was prepared by non-transferred DC arc plasma. ► Diatomic gasses were added in Ar plasma for high power. ► Prepared hollow alumina powder was efficient for the plasma spray coating

  5. Aluminium multi-planar hollow section traffic sign structures

    NARCIS (Netherlands)

    Soetens, F.

    1998-01-01

    Currently, overhead highway traffic sign structures in The Netherlands are triangular space frame girders composed of circular hollow steel sections supported by two X-shaped columns consisting of rectangular hollow steel sections. However. the Dutch Ministry of Transport has initiated the developme

  6. Americium transfer studies using hollow fiber/extractant membranes

    International Nuclear Information System (INIS)

    Americium can be removed from low acid/high nitrate feeds using hollow fiber membrane modules. Americium can be concentrated in the stripping solution. (Maximum observed concentration was a factor of 3.1). Accurel hollow fibers are less prone to leakage problems

  7. Fabrication of Closed Hollow Bulb Obturator Using Thermoplastic Resin Material

    Directory of Open Access Journals (Sweden)

    Bidhan Shrestha

    2015-01-01

    Full Text Available Purpose. Closed hollow bulb obturators are used for the rehabilitation of postmaxillectomy patients. However, the time consuming process, complexity of fabrication, water leakage, and discoloration are notable disadvantages of this technique. This paper describes a clinical report of fabricating closed hollow bulb obturator using a single flask and one time processing method for an acquired maxillary defect. Hard thermoplastic resin sheet has been used for the fabrication of hollow bulb part of the obturator. Method. After fabrication of master cast conventionally, bulb and lid part of the defect were formed separately and joined by autopolymerizing acrylic resin to form one sized smaller hollow body. During packing procedure, the defect area was loaded with heat polymerizing acrylic resin and then previously fabricated smaller hollow body was adapted over it. The whole area was then loaded with heat cure acrylic. Further processes were carried out conventionally. Conclusion. This technique uses single flask which reduces laboratory time and makes the procedure simple. The thickness of hollow bulb can be controlled and light weight closed hollow bulb prosthesis can be fabricated. It also minimizes the disadvantages of closed hollow bulb obturator such as water leakage, bacterial infection, and discoloration.

  8. Study of Torsional Impact Problem of Orthotropic Hollow Cylinder

    Institute of Scientific and Technical Information of China (English)

    杨华凯; 郝文华; 王熙

    2004-01-01

    A simple integral transform method was presented to solve the torsional impact problem of orthotropic hollow cylinder with mixed boundary condition. The analytical solution for the torsional impact problem of the orthotropic hollow cylinder was got. Some examples were calculated and discussed.

  9. Observations of three-dimensional needle deflection during insertion into soft tissue

    NARCIS (Netherlands)

    Jahya, Alex; Heijden, van der Ferdinand; Misra, Sarthak

    2012-01-01

    Accurate needle placement is important during percutaneous needle insertion procedures such as biopsy and brachytherapy. However, needle-tissue interactions may cause the needle to deviate from its intended path. In this paper, we have investigated the effects of insertion velocity, tip bevel angle

  10. Self-templated chemically stable hollow spherical covalent organic framework

    Science.gov (United States)

    Kandambeth, Sharath; Venkatesh, V.; Shinde, Digambar B.; Kumari, Sushma; Halder, Arjun; Verma, Sandeep; Banerjee, Rahul

    2015-04-01

    Covalent organic frameworks are a family of crystalline porous materials with promising applications. Although active research on the design and synthesis of covalent organic frameworks has been ongoing for almost a decade, the mechanisms of formation of covalent organic frameworks crystallites remain poorly understood. Here we report the synthesis of a hollow spherical covalent organic framework with mesoporous walls in a single-step template-free method. A detailed time-dependent study of hollow sphere formation reveals that an inside-out Ostwald ripening process is responsible for the hollow sphere formation. The synthesized covalent organic framework hollow spheres are highly porous (surface area ~1,500 m2 g-1), crystalline and chemically stable, due to the presence of strong intramolecular hydrogen bonding. These mesoporous hollow sphere covalent organic frameworks are used for a trypsin immobilization study, which shows an uptake of 15.5 μmol g-1 of trypsin.

  11. An Atomic Lens Using a Focusing Hollow Beam

    Institute of Scientific and Technical Information of China (English)

    夏勇; 印建平; 王育竹

    2003-01-01

    We propose a new method to generate a focused hollow laser beam by using an azimuthally distributed 2π-phase plate and a convergent thin lens, and calculate the intensity distribution of the focused hollow beam in free propagation space. The relationship between the waist w0 of the incident collimated Gaussian beam and the dark spot size of the focused hollow beam at the focal point, and the relationship between the focal length f of the thin lens and the dark spot size are studied respectively. The optical potential of the blue-detuned focused hollow beam for 85Rb atoms is calculated. Our study shows that when the larger waist w of the incident Gaussian beam and the shorter focal length f of the lens are chosen, we can obtain an extremely small dark spot size of the focused hollow beam, which can be used to form an atomic lens with a resolution of several angstroms.

  12. Hollow Casein-Based Polymeric Nanospheres for Opaque Coatings.

    Science.gov (United States)

    Zhang, Fan; Ma, Jianzhong; Xu, Qunna; Zhou, Jianhua; Simion, Demetra; Carmen, Gaidău; Wang, John; Li, Yunqi

    2016-05-11

    Casein-based hollow polymeric sphere were fabricated through emulsifier-free polymerization coupled with alkali swelling approach. Hollow structure and nanoscale size of casein-based polymeric spheres were verified by TEM, AFM, SEM, and UV-vis spectra. The as-obtained hollow spheres were proved exhibiting superior opaque characteristic. Through adjusting the structural parameters, for example, MAA usages and MAA content in seed to core, sphere film showed tunable visible-light transmittance and antiultraviolet property. The formation mechanism of casein-based hollow sphere has been discussed in depth. Worth mentioning, the resultant hollow polymeric sphere can easily form films itself at room temperature, which would open a new possibility of designing opaque coatings in several fields, such as leather, packaging, paper making, biomedical, and special indoor coating applications. PMID:27090208

  13. Back-washing method for hollow fiber membrane filter

    International Nuclear Information System (INIS)

    For processing condensates in a nuclear reactor, when the amount of the suspended matters contained in the condensates is increased upon filtering them through hollow fiber membrane, the hollow fiber membranes per se can no more be generated and have to be discarded. In view of the above, filtering operation is interrupted and air scrubbing is applied immediately for back-washing the hollow fiber membrane filters. Then, after filling water below a pipe plate and applying dome draining and dome pressurization, bumping is applied to the hollow fiber membranes. In this way, the scrubbing step is applied preferentially to the bumping step and a combination of the scrubbing and bumping step is repeated at least twice. This enables to conduct efficient back-washing and, accordingly, extend the life time of the hollow fiber membranes so that they can withstand long time use. (T.M.)

  14. PREPARATION OF HOLLOW LATEX PARTICLES BY ALKALI-ACID TREATMENT

    Institute of Scientific and Technical Information of China (English)

    郝冬梅; 王新灵; 朱卫华; 唐小真; 刘成岑; 施凯

    2001-01-01

    Hollow polymer latex particles were prepared by seeded emulsion polymerization. A seed latex consisting of styrene (St), butyl acrylate(BA) copolymer was first prepared, and seeded terpolymerization of St-BA-MA(methacrylic acid) were then carried out in the absence of surfactant. Final latex was treated by a two-step treatment under alkaline and acidic conditions, thus, the particles with hollow structure were obtained. We discussed the effects of pH value, temperature and time in alkali and acid treatment processes on hollow structure within the polymer latex particles and amount of carboxylic group on particle surface. The results show that the hollow polymer latex particles with the largest hollow size can be obtained under a certain condition (pH12.5, 90°C, 3 h in alkali treatment stage and pH2.5, 85°C, 3 h in acid treatment stage).

  15. Use of open-ended Foley catheter to treat profuse urine leakage around suprapubic catheter in a female patient with spina bifida who had undergone closure of urethra and suprapubic cystostomy: a case report

    OpenAIRE

    Vaidyanathan, Subramanian; Soni, Bakul M.; Peter L. Hughes; Singh, Gurpreet

    2009-01-01

    Introduction Leakage of urine around a catheter is not uncommon in spinal cord injury patients, who have indwelling urethral catheter. Aetiological factors for leakage of urine around a catheter are bladder spasms, partial blockage of catheter, constipation, and urine infection. Usually, leakage of urine subsides when the underlying cause is treated. Leakage of urine around a suprapubic catheter is very rare and occurs in patients, in whom the urethra is closed due to severe stricture or prev...

  16. NEEDLE ANATOMY CHANGES WITH INCREASING TREE AGE IN DOUGLAS FIR

    Science.gov (United States)

    Morphological differences between old growth and sapling (Pseudotsuga menziesii, (Mirb.) Franco) Douglas fir trees may extend to differences in needle anatomy. We used microscopy with image analysis to compare and quantify anatomical parameters in cross-sections of previous year...

  17. Warm-Needling Technique for Peripheral Facial Paralysis

    Institute of Scientific and Technical Information of China (English)

    WANG Chuan-nian; ZHOU Jing; SHAO Ming-hai

    2007-01-01

    Objective: To observe the therapeutic effects of warm-needling technique on peripheral facial paralysis. Methods: Warm-needling technique and electroacupuncture were employed to treat 30 cases of facial paralysis, respectively. The same acupoints, Cuanzhu(BL 2)towards Yuyao(Ex-HN 4), Yingxiang(LI 20) towards Xiaguan(ST 7), Taiyang(Ex-HN 5)towards Xuanlu(GB 5), Dicang(ST 4) towards Jiache(ST 6), and Chengjiang(CV 24) towards Daying(ST 5), were used. Results: After 33 treatments, the warm-needling technique has an effective rate of 83.3%, while the electroacupuncture 67.7%. Conclusion: The therapeutic effect of warm-needling technique was better than that of electroacupuncture method.

  18. Should fine needle aspiration cytology in breast assessment be abandoned?

    Energy Technology Data Exchange (ETDEWEB)

    Litherland, Janet C

    2002-02-01

    Fine needle aspiration cytology (FNAC) has been used extensively in the U.K. for the diagnosis of breast lesions over the past 15 years. More recently, large gauge needle biopsy has been used to address many of the problems which have been encountered with fine needle aspiration. This paper reviews the evolution of the use of these procedures and the advantages and disadvantages of each. In considering whether to abandon the use of fine needle aspiration cytology in breast assessment, each individual unit should make a decision based upon their own audited results. However, even if FNAC is retained, it is important to be able to complement cytological diagnosis with core biopsy as there are indisputable advantages, e.g. in the diagnosis of mammographically detected microcalcification. As always, a multi-disciplinary approach is ultimately essential for effective patient management. Litherland, J.C. (2002)

  19. Should fine needle aspiration cytology in breast assessment be abandoned?

    Science.gov (United States)

    Litherland, Janet C

    2002-02-01

    Fine needle aspiration cytology (FNAC) has been used extensively in the U.K. for the diagnosis of breast lesions over the past 15 years. More recently, large gauge needle biopsy has been used to address many of the problems which have been encountered with fine needle aspiration. This paper reviews the evolution of the use of these procedures and the advantages and disadvantages of each. In considering whether to abandon the use of fine needle aspiration cytology in breast assessment, each individual unit should make a decision based upon their own audited results. However, even if FNAC is retained, it is important to be able to complement cytological diagnosis with core biopsy as there are indisputable advantages, e.g. in the diagnosis of mammographically detected microcalcification. As always, a multi-disciplinary approach is ultimately essential for effective patient management. PMID:11977938

  20. [Infection of a hip prosthesis after dry needling].

    Science.gov (United States)

    Steentjes, Koen; de Vries, Lieke M A; Ridwan, Ben U; Wijgman, A J Jurgen

    2016-01-01

    A 57-year-old patient presented to the orthopaedic department with hip pain 7 months after hip replacement and two weeks after dry needling by a physiotherapist. Dry needling is used by physiotherapists to treat pain and stiffness. In the Netherlands, there are no clear guidelines or contra-indications described for this treatment. The surgical scar of our patient showed signs of inflammation for which debridement and irrigation were performed. Tissue samples showed positive bacterial cultures and the patient was treated with antibiotics. One week after completing this treatment, the infection returned. Debridement and irrigation were repeated and antibiotic treatment was recommenced. Three months later, the patient showed no signs of infection with the prosthesis still in situ. Although there is no strong evidence for a causal relationship between dry needling and the infection, dry needling should be used carefully in patients with a joint replacement, due to the increased risk of infection. PMID:26786794

  1. Percutaneous transhepatic biliary drainage using large needle: Complications and usefulness

    International Nuclear Information System (INIS)

    To analyse complications and to review usefulness of large needle(18G) in percutaneous transhepatic biliary drainage(PTBD). 46 patients underwent PTBD in 52 occasions using large needle. 44 of 46 patients had either definite or suspicious malignant biliary obstruction, and most patients were poor in general condition. Complications were classified as acute type if developed within 30 days and as delayed type if developed after 30 days. Acute type was subdivided into severe and mild forms. Severe forms of complications were death(5.8%), septicemia(3.8%), and bile peritonitis(1.9%). There were not different from the rate of complication in PTBD using fine needle but the procedure was much more simple. We PTBD using large needle is a simple and safe procedure for prompt bile decompression

  2. Percutaneous transhepatic biliary drainage using large needle: Complications and usefulness

    Energy Technology Data Exchange (ETDEWEB)

    Park, Noh Kyoung; Lim, Hyun Yang; Lee, Ji Yeon; Lee, Kil Jun; Tae, Seok; Shin, Kyoung Ja; Lee, Sang Chun [Seoul Red Cross Hospital, Seoul (Korea, Republic of)

    1994-06-15

    To analyse complications and to review usefulness of large needle(18G) in percutaneous transhepatic biliary drainage(PTBD). 46 patients underwent PTBD in 52 occasions using large needle. 44 of 46 patients had either definite or suspicious malignant biliary obstruction, and most patients were poor in general condition. Complications were classified as acute type if developed within 30 days and as delayed type if developed after 30 days. Acute type was subdivided into severe and mild forms. Severe forms of complications were death(5.8%), septicemia(3.8%), and bile peritonitis(1.9%). There were not different from the rate of complication in PTBD using fine needle but the procedure was much more simple. We PTBD using large needle is a simple and safe procedure for prompt bile decompression.

  3. Evaluation of Efficacy of Four Laparoscopic Needle Drivers

    OpenAIRE

    Ramani, Anup P.; Braasch, Matthew; Botnaru, Andrei; Lavers, Ann; Herrera, Shannon; Pedro, Renato Nardi; Monga, Manoj

    2008-01-01

    Introduction: To evaluate the impact of needle driver design on laparoscopic suturing skills by experts and novices. Methods: Three experienced laparoscopic surgeons and 3 novice junior residents were asked to perform a fixed set of suturing tasks in a laparoscopic pelvic-trainer. The laparoscopic needle drivers compared were (1) the Ethicon driver (E 705R), (2) Karl Storz (KS) pistol grip (26173 KC), (3) KS finger grip (26167 SK), and (4) KS palm grip (26173 ML). Times were recorded for each...

  4. Fine Needle Aspiration Cytology of Pediatric Thyroid Nodules

    OpenAIRE

    Ayper KAÇAR; İrem PAKER; Gülşah KABAÇAM BAYRAM; Fatma DEMİREL; Şenel, Emrah; Murat KIZILGÜN

    2010-01-01

    Objective: The objectives were to evaluate fine needle aspiration cytology results of 39 pediatric patients, and the pathologies that cause childhood thyroid nodules, and to review the literature on the subject.Material and Method: Thyroid fine needle aspiration cytology results of 39 pediatric patients were retrospectively reviewed. Associated diseases, thyroid functions, anti-thyroid antibody levels, ultrasonographic findings and number of nodules were also evaluated.Results: The vast major...

  5. ImaGiNe-S: Imaging Guided Needle Simulation

    OpenAIRE

    Bello, Fernando; Bulpitt, Andrew; Gould, Derek A.; Holbrey, Richard; Hunt, Carrie; How, Thien; John, Nigel W; Johnson, Sheena; Phillips, Roger; Sinha, Amrita; Vidal, Franck P; Villard, Pierre-Frédéric; Woolnough, Helen; Zhang, Yan

    2009-01-01

    We present an integrated system for training visceral needle puncture procedures. Our aim is to provide a cost effective and validated training tool that uses actual patient data to enable interventional radiology trainees to learn how to carry out image-guided needle puncture. The input data required is a computed tomography scan of the patient that is used to create the patient specific models. Force measurements have been made on real tissue and the resulting data is incorporated into the ...

  6. Developing An Immersive Ultrasound Guided Needle Puncture Simulator

    OpenAIRE

    Vidal, Franck P; Villard, Pierre-Frederic; Holbrey, Richard; John, Nigel W; Bello, Fernando; Bulpitt, Andrew; Gould, Derek A.

    2009-01-01

    We present an integrated system for training ultrasound guided needle puncture. Our aim is to provide a cost effective and validated training tool that uses actual patient data to enable interventional radiology trainees to learn how to carry out image-guided needle puncture. The input data required is a computed tomography scan of the patient that is used to create the patient specific models. Force measurements have been made on real tissue and the resulting data is incorporated into the si...

  7. A Needle Penetrating the Stomach Cavity after Acupuncture

    OpenAIRE

    Lee, Sin Won; Ahn, Ji Yong; Choi, Won Jung; Kim, Eun Jin; Bae, Seung-Hyeon; Choi, Yun Sik; Jung, Hwoon-Yong; Kim, Jin-Ho

    2014-01-01

    Although acupuncture is known as a safe procedure that is widely used in many countries, complications including infection, hemorrhage, hematoma, pneumothorax, nerve damage, and cardiac tamponade have been reported. A needle penetrating the stomach after acupuncture, however, is very rare. Here, we report the case of 47-year-old woman who experienced abdominal pain 2 days after receiving acupuncture. Upper gastrointestinal endoscopy identified an approximately 2.5-cm long needle in the poster...

  8. Transthoracic needle aspiration: the past, present and future

    OpenAIRE

    Chockalingam, Arun; Hong, Kelvin

    2015-01-01

    Transthoracic needle aspiration (TTNA) has been used to diagnose disease in the lung for many decades. Thanks to advances in technology and cytopathology, the diagnostic power, accuracy, safety, and efficacy of TTNA are constantly improving. The transition from fluoroscopy to computed tomography (CT) has yielded better visualization, and ability to enhance sophistication of tools used to biopsy. In addition, needles are being refined for obtaining better biopsy samples and increased capabilit...

  9. Endoscopic and endosonography guided fine-needle aspiration.

    Science.gov (United States)

    Antillon, M R; Chang, K J

    2000-10-01

    Endoscopic ultrasound-guided fine-needle aspiration is emerging as the preferred technique for the cytologic diagnosis of various gastrointestinal lesions. This technique may not be routinely available, but there is still a role for endoscopic or endoscopic ultrasound-assisted fine-needle aspiration. This article provides an overview of the evolution of these various techniques and discusses the advantages, disadvantages, indications, and contraindications of each. PMID:11036536

  10. Enterobacter aerogenes Needle Stick Leads to Improved Biological Management System

    Energy Technology Data Exchange (ETDEWEB)

    Johanson, Richard E.

    2004-08-01

    A laboratory worker who received a needle stick from a contaminated needle while working with a culture containing Enterobactor aerogenes developed a laboratory acquired infection. Although this organism has been shown to cause community and nosocomial infections, there have been no documented cases of a laboratory acquired infections. Lessons learned from the event led to corrective actions which included modification of lab procedures, development of a biological inventory tracking and risk identification system and the establishment of an effective biological safety program.

  11. Optical fine-needle imaging biopsy of the brain

    OpenAIRE

    Kim, Jun Ki; Choi, Jin Woo; Yun, Seok H.

    2013-01-01

    We demonstrate optical fine-needle imaging biopsy (FNIB), combining a fine needle (22 gauge) and a high-resolution side-view probe (350-μm diameter) for minimally invasive interrogation of brain tissue in situ. We apply this technique to examine pathogenesis in murine models of neurodegeneration, brain metastasis of melanoma, and arterial occlusion, respectively. The demonstrated ability to obtain cellular images in the deep brain without craniotomy may be useful in the longitudinal studies o...

  12. Long-term evaluation of hollow screw and hollow cylinder dental implants : Clinical and radiographic results after 10 years

    NARCIS (Netherlands)

    Telleman, Gerdien; Meijer, Henny J. A.; Raghoebar, Gerry M.

    2006-01-01

    Background: In 1988, an implant manufacturer offered a new dental implant system, with a wide choice of hollow cylinder (HC) and hollow screw (HS) implants. The purpose of this retrospective study of HS and HC implants was to evaluate clinical and radiographic parameters of peri-implant tissue and t

  13. Fine needle aspiration cytology in leprosy

    Directory of Open Access Journals (Sweden)

    Prasad PVS

    2008-01-01

    Full Text Available Background: Laboratory diagnosis of leprosy by slit skin smear and skin biopsy is simple but both techniques have their own limitations. Slit skin smear is negative in paucibacillary cases whereas skin biopsy is an invasive technique. Fine needle aspiration cytology (FNAC from skin lesions in leprosy with subsequent staining with May-Grunwald-Giemsa (MGG stain has been found useful. Aim: To evaluate the possible role of cytology in classifying leprosy patients. Methods: Seventy-five untreated cases of leprosy attending the outpatient department were evaluated. Smears were taken from their skin lesions and stained using the MGG technique. Skin biopsy was also done from the lesions, which was compared with cytology smears. Results: A correlation of clinical features with FNAC was noticed in 87.5% of TT, 92.1% of BT, 81% of BL, and 66% of LL cases. Correlation of clinical with histopathological diagnoses revealed 12.5% specificity in TT leprosy, 55.3% in BT, 52.4% in BL and 50% in LL, and 100% in neuritic and histoid leprosy cases. Both correlations were found to be statistically significant by paired t test analysis. Thus, it was possible to distinguish the tuberculoid types by the presence of epithelioid cells and the lepromatous types by the presence of lymphocytes and foamy macrophages. Conclusion: FNAC may be used to categorize the patients into paucibacillary and multibacillary types, but is not a very sensitive tool to classify the patients across the Ridley-Jopling spectrum.

  14. Susuks (charm needles) in the craniofacial region

    International Nuclear Information System (INIS)

    We conducted a study to determine the numbers of susuks (charm needles) and their distribution in the craniofacial region of susuk wearers, and the sex, racial affiliation, and age of the wearers. In addition, we sought to determine whether the presence of susuks posed any potential hazard to patients undergoing magnetic resonance imaging (MRI). We studied various radiographs of 33 susuk wearers (age range, 33-69 years) and investigated the most common sites of insertion in the craniofacial region. A susuk was also suspended inside a 1.5-T MRI machine to determined whether it was attracted by the machine's magnet. The largest number of susuks that we observed in the craniofacial region was 39 pins, and susuks were particularly numerous in Malay Muslim women. Other sites with susuks were the maxillofacial region (except the temporomandibular region) and the forehead. The susuks showed no ferromagnetic characteristics. As susuks are made from gold, they are generally biocompatible with human tissue and do not cause problems to their wearers. Gold and the other minor metal constituents found in susuks have no ferromagnetic characteristics and therefore pose no hazard to patients undergoing MRI. (author)

  15. Percutaneous transhepatic cholangiography using fine needle

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Kyoo Byung; Kim, Yun Hwan; Lee, Nam Joon; Suh, Won Hyuck [College of Medicine, Korea University, Seoul (Korea, Republic of)

    1980-12-15

    In recent years, percutaneous transhepatic cholangiography (PTC) using fine needle has become widely employed as the procedure of choice for direct opacification of the biliary trees because of its high success rate, easy performance and relative low complication rate. Authors present the clinical and PTC findings of experienced cases during last four years, from May 1976 to June 1980, at the Department of Radiology, Korea University Hospital. We tried to study of PTC in 44 cases, 32 males and 12 females, and succeeded in visualization of bile ducts in 41 cases, but the other three cases were failed to visualize the bile ducts. Final confirmative diagnosis was achieved in 29 cases by operation, laparoscopy and other clinical methods. The PTC diagnosis was correct in 24 of 29 cases, and the others were incorrect. The 29 final diagnosis was including 13 cases of biliary stones, 6 cases of biliary cancer, 3 cases of pancreatic cancer, 3 cases of clonorchiasis, one case of CBD ascariasis and 3 cases of others. Incorrect PTC diagnosis was made in five cases. They were one case of nonvisualized intrahepatic stones, one case of hepatoma PTC diagnosed as cholangiocarcinoma, one case of pancreatic cancer diagnosed as cholangiocarcinoma, one case of clonorchiasis diagnosed as biliary stones and one case of normal CBD which was diagnosed as distal CBD cancer. And we experienced one case of bile peritonitis as complication, who was 35 year-old female patient with multiple CBD stones, and aspirated about 500ml of bile stained ascites during operation.

  16. Percutaneous transhepatic cholangiography using fine needle

    International Nuclear Information System (INIS)

    In recent years, percutaneous transhepatic cholangiography (PTC) using fine needle has become widely employed as the procedure of choice for direct opacification of the biliary trees because of its high success rate, easy performance and relative low complication rate. Authors present the clinical and PTC findings of experienced cases during last four years, from May 1976 to June 1980, at the Department of Radiology, Korea University Hospital. We tried to study of PTC in 44 cases, 32 males and 12 females, and succeeded in visualization of bile ducts in 41 cases, but the other three cases were failed to visualize the bile ducts. Final confirmative diagnosis was achieved in 29 cases by operation, laparoscopy and other clinical methods. The PTC diagnosis was correct in 24 of 29 cases, and the others were incorrect. The 29 final diagnosis was including 13 cases of biliary stones, 6 cases of biliary cancer, 3 cases of pancreatic cancer, 3 cases of clonorchiasis, one case of CBD ascariasis and 3 cases of others. Incorrect PTC diagnosis was made in five cases. They were one case of nonvisualized intrahepatic stones, one case of hepatoma PTC diagnosed as cholangiocarcinoma, one case of pancreatic cancer diagnosed as cholangiocarcinoma, one case of clonorchiasis diagnosed as biliary stones and one case of normal CBD which was diagnosed as distal CBD cancer. And we experienced one case of bile peritonitis as complication, who was 35 year-old female patient with multiple CBD stones, and aspirated about 500ml of bile stained ascites during operation

  17. Analysis on enzymatic browning in pine needles

    Energy Technology Data Exchange (ETDEWEB)

    Kong, K.H.; Park, H.J.; Choi, S.S.; Cho, S.H. [Chung-Ang University, Seoul (Korea); Kim, Y.T. [Aoyama Gakuin University, Tokyo (Japan)

    1999-06-01

    Tyrosinases are related to the enzymatic browning of plants and attract the major scientific interest for the prevention of it. Three tyrosinase isozymes (P{sub 1}, P{sub 2} and P{sub 3}) from pine needles were purified to homogeneity and characterized the factors that affect their activities. The L-ascorbic acid and {beta}-mercaptoethanol notably inhibited the enzymatic activities of the three isozymes. The sodium diethyldithiocarbamate was a competitive inhibitor of isozymes with the K{sub i} values of P{sub 1}(0.30 mM), P{sub 2}(0.015 mM) and P{sub 3}(0.019 mM), respectively. Their enzyme activities were however, increased by the addition of most metal ions. The optimum pH for the three isozymes was 9.0{approx}9.5 and the optimum temperatures ranged from 55 to 60{sup o} C using L-DOPA as substrate. 15 refs., 3 figs., 2 tabs.

  18. Micro-needle electro-tactile display.

    Science.gov (United States)

    Tezuka, Mayuko; Kitamura, Norihide; Miki, Norihisa

    2015-08-01

    Haptic feedback is strongly demanded for high-precision robot-assisted surgery and teleoperation. The haptic feedback consists of force and tactile feedback, however tactile feedback has been little studied and the size and weight of the system poses challenges for practical applications. In this paper we propose a sheet-type wearable electro-tactile display which provides tactile sensations to the user as the feedback at a low voltage and power consumption. The display possesses needle-shaped electrodes, which can penetrate through the high-impedance stratum corneum. We developed the fabrication process and, as the first step, we investigated the tactile sensation that can be created to the fingertip by the display. Rough and smooth surfaces were successfully presented to the user. Then, we characterized the tactile display when used on the forearm, in particular, with respect to the spatial resolution. These tactile displays can be used to inform the user of the surface property of the parts of interest, such as tumor tissues, and to guide him in the manipulation of surgery robots. PMID:26737606

  19. Needle core biopsy for breast lesions: An audit of 467 needle core biopsies

    Directory of Open Access Journals (Sweden)

    Selvi Radhakrishna

    2013-01-01

    Full Text Available Background: Breast cancer is the commonest cancer among women in urban India. Triple assessment includes clinical, radiological and cytological assessment of breast lesions. Guided core needle biopsy has replaced fine needle aspiration cytology in most of the western countries. In resource poor countries FNAC is still a very valuable and cost effective method to diagnose breast lesions. Pitfalls include increased rates of non diagnostic smears, and inadequate smears. Further procedures may be required and this increases the cost, anxiety and delay in diagnosis. Aims: The aim of this study is to analyze the concordance of radiological and histopathology findings in BI-RADS category 3,4,5 lesions following a core biopsy. Materials and Methods: Data was retrospectively collected from consecutive symptomatic and opportunistic screen detected patients with abnormalities who underwent ultrasound guided interventional procedures from Jan 2010 to Aug 2011. Symptomatic patients underwent clinical examination, mammogram and breast ultrasound. Women under 35 years of age had only breast ultrasound. Core biopsy was performed under ultrasound guidance or clinically by a breast surgeon/ radiologist for BI-RADS category 3,4,5 lesions. Statistical Methods: Chi square test was done to show the strength of association of imaging findings and histopathology results of core biopsy. Results: 437 patients were symptomatic and 30 patients had screen detected abnormalities. The positive predictive value for BI-RADS 5 lesions for malignancy is 93.25% and the negative predictive value of BI-RADS category 3 lesions for cancer is 98.4%. False negative diagnosis on core biopsy was 0.85%. We were able to defer surgery in 60% of the patients with a clear radiological and pathological benign diagnosis. Conclusion: The PPV and NPV for cancer is high with needle core biopsy in BI-RADS 3,4,5 lesions. Where there is no discordance between clinical, radiology and pathology findings

  20. Metal-Matrix/Hollow-Ceramic-Sphere Composites

    Science.gov (United States)

    Baker, Dean M.

    2011-01-01

    A family of metal/ceramic composite materials has been developed that are relatively inexpensive, lightweight alternatives to structural materials that are typified by beryllium, aluminum, and graphite/epoxy composites. These metal/ceramic composites were originally intended to replace beryllium (which is toxic and expensive) as a structural material for lightweight mirrors for aerospace applications. These materials also have potential utility in automotive and many other terrestrial applications in which there are requirements for lightweight materials that have high strengths and other tailorable properties as described below. The ceramic component of a material in this family consists of hollow ceramic spheres that have been formulated to be lightweight (0.5 g/cm3) and have high crush strength [40.80 ksi (.276.552 MPa)]. The hollow spheres are coated with a metal to enhance a specific performance . such as shielding against radiation (cosmic rays or x rays) or against electromagnetic interference at radio and lower frequencies, or a material to reduce the coefficient of thermal expansion (CTE) of the final composite material, and/or materials to mitigate any mismatch between the spheres and the matrix metal. Because of the high crush strength of the spheres, the initial composite workpiece can be forged or extruded into a high-strength part. The total time taken in processing from the raw ingredients to a finished part is typically 10 to 14 days depending on machining required.

  1. Needle stick injury in a radiology department: a decade analysis

    International Nuclear Information System (INIS)

    Objectives: To determine the frequency of needle stick injury in health care workers of radiology department. Study type, settings and duration: Cross sectional, observational study conducted at the Radiology department of Aga Khan University hospital from January 2000 to May 2010. Subject and Methods: All self-reported needle stick injuries data of Health care workers of radiology department was recorded. The personnel involved (Radiologist, resident, radiographer, nurses etc), area of working and the causes of injury were identified including the procedural or post procedural details. Patient's status of hepatitis or blood borne infection was also noted. Data was recorded and analyzed in Excel worksheet. Results: A total of 55 health workers reported needle stick injuries at all sections of radiology departments with maximum number needle stick injuries at general radiography, fluoroscopy and IVP section. Radiographers and radiology residents received the maximum number of injuries. Major cause of injury was cannulation however, many injuries occurred during disposing or handling of bin. In majority of cases the patients were not infected with any known blood borne infections. Conclusions: Doctors and nurses get needle-stick injuries while carrying out clinical procedures, while, ancillary staff get infected post procedure during disposal of garbage. Policy message: Good occupational health and safety practices must be promoted to all staff. Safer disposal of needles is an important area where practice and procedure needs to be carefully reviewed. It is necessary to undertake a risk assessment, to offer counseling and Post Exposure Prophylaxis and treatment where necessary. (author)

  2. Picosecond optical vortex pulse illumination forms a monocrystalline silicon needle.

    Science.gov (United States)

    Takahashi, Fuyuto; Miyamoto, Katsuhiko; Hidai, Hirofumi; Yamane, Keisaku; Morita, Ryuji; Omatsu, Takashige

    2016-01-01

    The formation of a monocrystalline silicon needle by picosecond optical vortex pulse illumination was demonstrated for the first time in this study. The dynamics of this silicon needle formation was further revealed by employing an ultrahigh-speed camera. The melted silicon was collected through picosecond pulse deposition to the dark core of the optical vortex, forming the silicon needle on a submicrosecond time scale. The needle was composed of monocrystalline silicon with the same lattice index (100) as that of the silicon substrate, and had a height of approximately 14 μm and a thickness of approximately 3 μm. Overlaid vortex pulses allowed the needle to be shaped with a height of approximately 40 μm without any changes to the crystalline properties. Such a monocrystalline silicon needle can be applied to devices in many fields, such as core-shell structures for silicon photonics and photovoltaic devices as well as nano- or microelectromechanical systems. PMID:26907639

  3. Transbronchial needle aspirates: how many passes per target site?

    Science.gov (United States)

    Diacon, A H; Schuurmans, M M; Theron, J; Brundyn, K; Louw, M; Wright, C A; Bolliger, C T

    2007-01-01

    Transbronchial needle aspiration is a bronchoscopic sampling method for a variety of bronchial and pulmonary lesions. The present study investigated whether and how serial needle passes contribute to the yield of transbronchial needle aspiration at specific target sites. A total of 1,562 needle passes, performed at 374 target sites in 245 patients with neoplastic disease (82%), non-neoplastic disease (15%) or undiagnosed lesions (3%), were prospectively recorded and rated for anatomical location, size, bronchoscopic appearance and underlying disease. Positive aspirates were obtained in 75% of patients and at 68% of target sites. A diagnosis was established with the first, second, third and fourth needle pass at 64, 87, 95 and 98% of targets, respectively. The absolute yield varied strongly with target site features, but the stepwise increment to the maximum yield provided by serial passes was similar across target sites. In conclusion, three transbronchial needle passes per site are appropriate when only a tissue diagnosis is sought and when alternative sites or sampling modalities are available. At least four or five passes should be carried out at lymph node stations critical for the staging of lung cancer. PMID:17005579

  4. Neuromuscular Damage and Repair after Dry Needling in Mice

    Directory of Open Access Journals (Sweden)

    Ares Domingo

    2013-01-01

    Full Text Available Objective. Some dry needling treatments involve repetitive and rapid needle insertions into myofascial trigger points. This type of treatment causes muscle injury and can also damage nerve fibers. The aim of this study is to determine the injury caused by 15 repetitive punctures in the muscle and the intramuscular nerves in healthy mouse muscle and its ulterior regeneration. Methods. We repeatedly needled the levator auris longus muscle of mice, and then the muscles were processed with immunohistochemistry, methylene blue, and electron microscopy techniques. Results. Three hours after the dry needling procedure, the muscle fibers showed some signs of an inflammatory response, which progressed to greater intensity 24 hours after the procedure. Some inflammatory cells could still be seen when the muscle regeneration was almost complete seven days after the treatment. One day after the treatment, some changes in the distribution of receptors could be observed in the denervated postsynaptic component. Reinnervation was complete by the third day after the dry needling procedure. We also saw very fine axonal branches reinnervating all the postsynaptic components and some residual sprouts the same day. Conclusion. Repeated dry needling punctures in muscle do not perturb the different stages of muscle regeneration and reinnervation.

  5. Air Separation Using Hollow Fiber Membranes

    Science.gov (United States)

    Huang, Stephen E.

    2004-01-01

    The NASA Glenn Research Center in partnership with the Ohio Aerospace Institute provides internship programs for high school and college students in the areas of science, engineering, professional administrative, and other technical areas. During the summer of 2004, I worked with Dr. Clarence T. Chang at NASA Glenn Research Center s combustion branch on air separation using hollow fiber membrane technology. . In light of the accident of Trans World Airline s flight 800, FAA has mandated that a suitable solution be created to prevent the ignition of fuel tanks in aircrafts. In order for any type of fuel to ignite, three important things are needed: fuel vapor, oxygen, and an energy source. Two different ways to make fuel tanks less likely to ignite are reformulating the fuel to obtain a lower vapor pressure for the fuel and or using an On Board Inert Gas Generating System (OBIGGS) to inert the Central Wing Tank. goal is to accomplish the mission, which means that the Air Separation Module (ASM) tends to be bulky and heavy. The primary goal for commercial aviation companies is to transport as much as they can with the least amount of cost and fuel per person, therefore the ASM must be compact and light as possible. The plan is to take bleed air from the aircraft s engines to pass air through a filter first to remove particulates and then pass the air through the ASM containing hollow fiber membranes. In the lab, there will be a heating element provided to simulate the temperature of the bleed air that will be entering the ASM and analysis of the separated air will be analyzed by a Gas Chromatograph/Mass Spectrometer (GC/MS). The GUMS will separate the different compounds in the exit streams of the ASM and provide information on the performance of hollow fiber membranes. Hopefully I can develop ways to improve efficiency of the ASM. different types of jet fuel were analyzed and data was well represented on SAE Paper 982485. Data consisted of the concentrations of over

  6. Irrigated Tip Catheters for Radiofrequency Ablation in Ventricular Tachycardia

    Directory of Open Access Journals (Sweden)

    Andreas Müssigbrodt

    2015-01-01

    Full Text Available Radiofrequency (RF ablation with irrigated tip catheters decreases the likelihood of thrombus and char formation and enables the creation of larger lesions. Due to the potential dramatic consequences, the prevention of thromboembolic events is of particular importance for left-sided procedures. Although acute success rates of ventricular tachycardia (VT ablation are satisfactory, recurrence rate is high. Apart from the progress of the underlying disease, reconduction and the lack of effective transmural lesions play a major role for VT recurrences. This paper reviews principles of lesion formation with radiofrequency and the effect of tip irrigation as well as recent advances in new technology. Potential areas of further development of catheter technology might be the improvement of mapping by better substrate definition and resolution, the introduction of bipolar and multipolar ablation techniques into clinical routine, and the use of alternative sources of energy.

  7. Usefulness and safety of the GuideLiner catheter to enhance intubation and support of guide catheters: insights from the Twente GuideLiner registry

    NARCIS (Netherlands)

    Man, de F.H.; Birgelen, von C.; et al,

    2012-01-01

    Aims: Optimal ostial seating and adequate back-up of guide catheters are required for challenging percutaneous coronary interventions (PCI). The GuideLiner™ (GL) (Vascular Solutions Inc., Minneapolis, MN, USA) is a guide catheter extension system that provides active back-up support by deep coronary

  8. Symptomatic improvement after radiofrequency catheter ablation for typical atrial flutter

    OpenAIRE

    O'Callaghan, P.; Meara, M; Kongsgaard, E; Poloniecki, J.; Luddington, L; Foran, J; Camm, A; Rowland, E; Ward, D.

    2001-01-01

    OBJECTIVE—To assess the changes in quality of life, arrhythmia symptoms, and hospital resource utilisation following catheter ablation of typical atrial flutter.
DESIGN—Patient questionnaire to compare the time interval following ablation with a similar time interval before ablation.
SETTING—Tertiary referral centre.
PATIENTS—63 consecutive patients were studied. Four patients subsequently underwent an ablate and pace procedure, two died of co-morbid illnesses, and two were lost to follow up....

  9. Determination of lesion size by ultrasound during radiofrequency catheter ablation.

    Science.gov (United States)

    Awad, S; Eick, O

    2003-01-01

    The catheter tip temperature that is used to control the radiofrequency generator output poorly correlates to lesion size. We, therefore, evaluated lesions created in vitro using a B-mode ultrasound imaging device as a potential means to assess lesion generation during RF applications non-invasively. Porcine ventricular tissue was immersed in saline solution at 37 degrees C. The catheter was fixed in a holder and positioned in a parallel orientation to the tissue with an array transducer (7.5 MHz) app. 3 cm above the tissue. Lesions were produced either in a temperature controlled mode with a 4-mm tip catheter with different target temperatures (50, 60, 70 and 80 degrees C, 80 W maximum output) or in a power controlled mode (25, 50 and 75 W, 20 ml/min irrigation flow) using an irrigated tip catheter. Different contact forces (0.5 N, 1.0 N) were tested, and RF was delivered for 60 s. A total of 138 lesions was produced. Out of these, 128 could be identified on the ultrasound image. The lesion depth and volume was on average 4.1 +/- 1.6 mm and 52 +/- 53 mm3 as determined by ultrasound and 3.9 +/- 1.7 mm and 52 +/- 55 mm3 as measured thereafter, respectively. A linear correlation between the lesion size determined by ultrasound and that measured thereafter was demonstrated with a correlation coefficient of r = 0.87 for lesion depth and r = 0.93 for lesion volume. We conclude that lesions can be assessed by B-mode ultrasound imaging. PMID:12910859

  10. Neurostimulation leads, intrathecal catheters and anchoring devices evolution

    OpenAIRE

    Laura Demartini; Gianluca Conversa; Luciana Armiento; Lucia Angelini; Cesare Bonezzi

    2015-01-01

    Many scientific studies highlight the usefulness of spinal cord stimulation and intrathecal therapy for the management of chronic pain syndromes resistant to pharmacological or less invasive interventional therapies. One of the possible complications of these techniques, reported in literature, is migration of the lead or catheter; thus the use of an anchoring system is considered mandatory. Every company that produces devices for neurostimulation or neuromodulation provides various anchoring...

  11. EVALUATION OF A NEW CATHETER FOR ESOPHAGEAL PH MONITORING

    NARCIS (Netherlands)

    KUIT, JA; SCHEPEL, SJ; BIJLEVELD, CMA; KLEIBEUKER, JH

    1991-01-01

    A new catheter, provided with an Ion Sensitive Field Effect Transistor as a pH sensor and incorporating a reference electrode, was evaluated for esophageal pH recording. The pH-sensitivity was 54 mV/pH in vitro, with a linear response between pH 2 and pH 9. Clinical semi-ambulatory 24-hour esophagea

  12. Engineering out the risk for infection with urinary catheters.

    OpenAIRE

    Maki, D G; Tambyah, P.A.

    2001-01-01

    Catheter-associated urinary tract infection (CAUTI) is the most common nosocomial infection. Each year, more than 1 million patients in U.S. acute-care hospitals and extended-care facilities acquire such an infection; the risk with short-term catheterization is 5% per day. CAUTI is the second most common cause of nosocomial bloodstream infection, and studies suggest that patients with CAUTI have an increased institutional death rate, unrelated to the development of urosepsis. Novel urinary ca...

  13. Remote control catheter navigation: options for guidance under MRI

    OpenAIRE

    Muller Leah; Saeed Maythem; Wilson Mark W; Hetts Steven W

    2012-01-01

    Abstract Background Image-guided endovascular interventions have gained increasing popularity in clinical practice, and magnetic resonance imaging (MRI) is emerging as an attractive alternative to X-ray fluoroscopy for guiding such interventions. Steering catheters by remote control under MRI guidance offers unique challenges and opportunities. Methods In this review, the benefits and limitations of MRI-guided remote control intervention are addressed, and the tools for guiding such intervent...

  14. Microbiological pattern of arterial catheters in the intensive care unit

    Directory of Open Access Journals (Sweden)

    Patel Bharat

    2010-10-01

    Full Text Available Abstract Background Intravascular catheter related infection (CRI is one of the most serious nosocomial infections. Diagnostic criteria include a positive culture from the catheter tip along with blood, yet in many patients with signs of infection, current culture techniques fail to identify pathogens on catheter segments. We hypothesised that a molecular examination of the bacterial community on short term arterial catheters (ACs would improve our understanding of the variety of organisms that are present in this niche environment and would help develop new methods for the diagnosis of CRI. Results The whole bacterial community presenting on all ACs was evaluated by molecular methods, i.e., a strategy of whole community DNA extraction, PCR amplification followed by cloning and 16S rDNA sequence analysis. Ten ACs were removed from patients suspected of CRI and 430 clones from 5 "colonised" and 5 "uncolonised" (semi-quantitative method AC libraries were selected for sequencing and subsequent analysis. A total of 79 operational taxonomic units (OTUs were identified at the level of 97% similarity belonging to six bacterial divisions. An average of 20 OTUs were present in each AC, irrespective of colonisation status. Conventional culture failed to reveal the majority of these bacteria. Conclusions There was no significant difference in the bacterial diversity between the 'uncolonised' and 'colonised' ACs. This suggests that vascular devices cultured conventionally and reported as non infective may at times potentially be a significant source of sepsis in critically ill patients. Alternative methods may be required for the accurate diagnosis of CRI in critically ill patients.

  15. Recycling of catheters used in angiography. Communication 1

    International Nuclear Information System (INIS)

    Recycling and resterilisation of throwaway articles - in radiology especially of catheters used in angiography - has become widespread to save costs. Although extensive experimental work in this field is still lacking, criteria have been set up as guidelines to ensure safe recycling. These are subdivided into three parts: Cleaning - sterilisation - material testing. Experimental studies have been reported on sterilisation only proving the inadequacy of two ethylene oxide methods conventionally used in hospitals. (orig.)

  16. A catheter related sepsis case caused by Pantoea agglomerans

    Directory of Open Access Journals (Sweden)

    Fadime Yılmaz

    2015-04-01

    microorganism was sensitive to piperacillin-tazobactam, so, patient's therapy was not changed. After treatment, when the general condition of the patient healed, he was discharged by ending antibiotics on the sixteenth day. This case report, is intended to call attention to the risk of the growth of catheter-associated sepsis and antibioterapi are lated to P. agglomerans which is rarely seen on immunocompromised patients.

  17. Neuropsychological Decline After Catheter Ablation of Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Schwarz, N

    2011-09-01

    Full Text Available The article “Neuropsychological decline after cath- eter ablation of atrial fibrillation” by Schwarz et al. is the first publication that focused on cognitive side effects of elective circumferential pulmonary vein isolation (PVI.1 Adverse neuropsychological changes after left atrial catheter ablation, as report- ed in this paper, were found in verbal memory and the result, conjoined with ischemic brain lesions, might represent cerebral side-effects of the ablation procedure.

  18. Catheter Ablation without Fluoroscopy: Current Techniques and Future Direction

    Directory of Open Access Journals (Sweden)

    Amee M. Bigelow, MD; Grace Smith, MD; John M. Clark, MD

    2014-04-01

    Full Text Available Background: Catheter ablation is the treatment of choice for most forms of SVT. Traditionally, fluoroscopy has been the primary tool for visualizing catheter position. However, newer, 3-dimensional mapping technologies offer multiple options for minimizing fluoroscopy use. We review our 8 year experience of a zero-fluoroscopy approach using the Ensite system, and discuss our current techniques. Methods: From January 2006 to October 2013, we performed 524 catheter ablation procedures with a zero-fluoroscopy approach. The Ensite system was used exclusively. Early in the study, NavX mode was employed. In the later time period, Velocity mode was used. The Ensite system allowed easy access to all right sided arrhythmias. For left sided arrhythmias, TEE was added to aid with transseptal puncture. Results: Reviewing 524 consecutive procedures, mean age was 14 years (range 7 weeks to 65 years. Mean weight was 60.7 kg (range 3 to 174 kg. Mean procedure time was 142 minutes (range 42 – 402 minutes. There were no complications. Twenty -five patients required the use of fluoroscopy, mostly as part of simultaneous diagnostic or interventional cath procedures. There was only one instance in which fluoroscopy was used when not anticipated at the start of the procedure. With this data available, and seeing that fluoroscopy is rarely needed unexpectedly, we hypothesized that catheter ablation no longer requires a traditional cath lab. We present our early approach to ablation outside the catheterization lab. Conclusion: Three dimensional mapping systems can eliminate fluoroscopy use in virtually all routine ablation procedures. As technology improves, ablation procedures will shift beyond the traditional cath lab.

  19. Percutaneous transthoracic cutting needle biopsy of pulmonary lesions: comparison of the use of 18 and 20 gauge needles

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chun Chang; Jin, Gong Yong; Han, Young Min; Park, Hak Hun; Kwon, Keun Sang [Chonbuk National University Hospital, Medical School, Research Institute of Clinical Medicine, Jeonju(Korea, Republic of)

    2008-05-15

    We evaluated the usefulness of a CT guided percutaneous transthoracic cutting needle biopsy (PCNB) using a 20 gauge (G) needle for pulmonary lesions after a comparison with the use of an 18 G needle for diagnostic accuracy and complications. From August 2005 to July 2007, 433 patients underwent a CT guided PCNB. A total of 191 patients were excluded from the study as these patients had benign lesions seen after PCNB, but did not receive a confirmation biopsy or undergo follow-up (> 1 year). We evaluated the diagnostic accuracy for the use of PCNB using the Chi-squared test and analyzed which factors (location and size of lesions, diameter of the needle, distance between the pleura and lesions, presence or not of emphysema) were related to occurrence of a pneumothorax after PCNB using a multi-variant regression test. The diagnostic accuracy for malignant lesions with the use of an 18 G and a 20 G needle were 95.4% and 97%, respectively. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for the use of an 18 G needle were 95.7%, 100%, 100%, and 91.6%. The sensitivity, specificity, PPV, and NPV were 97.8%, 100%, 100%, and 95.0% for the use of a 20 G needle. A pneumothorax occurred in 5.5% (24/433) of the cases and was closely related to the distance from the pleura to the lesions. CT guided PCNB with the use of a 20 gauge needle provided good diagnostic accuracy and the procedure is safe to perform.

  20. Comparison of Fine Needle Aspiration and Fine Needle Nonaspiration Cytology of Thyroid Nodules: A Meta-Analysis

    OpenAIRE

    Hongming Song; Chuankui Wei; Dengfeng Li; Kaiyao Hua; Jialu Song; Niraj Maskey; Lin Fang

    2015-01-01

    Background. Fine needle aspiration cytology (FNAC) and fine needle nonaspiration cytology (FNNAC) are useful cost-effective techniques for preoperatively assessing thyroid lesions. Both techniques have advantages and disadvantages, and there is controversy over which method is superior. This meta-analysis was performed to evaluate the differences between FNAC and FNNAC for diagnosis of thyroid nodules. Methods. Primary publications were independently collected by two reviewers from PubMed, We...