WorldWideScience

Sample records for cardiac pacemaker batteries

  1. [Cardiac Pacemakers, implantable defibrillators and IRM].

    Science.gov (United States)

    Frank, R; Hidden-Lucet, F; Himbert, C; Petitot, J C; Fontaine, G

    2003-04-01

    The IRM is formally contraindicated to the pacemaker and cardiac defibrillator wearers because of the risk of inhibition or inappropriate stimulations during the examination. However if the examination is essential, suitable programming of the apparatus and a constant monitoring of the heartbeat rate by a qualified doctor in cardiac stimulation must make it possible to avoid any accident.

  2. Pacemaker interactions induce reentrant wave dynamics in engineered cardiac culture

    Science.gov (United States)

    Borek, Bartłomiej; Shajahan, T. K.; Gabriels, James; Hodge, Alex; Glass, Leon; Shrier, Alvin

    2012-09-01

    Pacemaker interactions can lead to complex wave dynamics seen in certain types of cardiac arrhythmias. We use experimental and mathematical models of pacemakers in heterogeneous excitable media to investigate how pacemaker interactions can be a mechanism for wave break and reentrant wave dynamics. Embryonic chick ventricular cells are cultured invitro so as to create a dominant central pacemaker site that entrains other pacemakers in the medium. Exposure of those cultures to a potassium channel blocker, E-4031, leads to emergence of peripheral pacemakers that compete with each other and with the central pacemaker. Waves emitted by faster pacemakers break up over the slower pacemaker to form reentrant waves. Similar dynamics are observed in a modified FitzHugh-Nagumo model of heterogeneous excitable media with two distinct sites of pacemaking. These findings elucidate a mechanism of pacemaker-induced reentry in excitable media.

  3. Generation of cardiac pacemaker cells by programming and differentiation.

    Science.gov (United States)

    Husse, Britta; Franz, Wolfgang-Michael

    2016-07-01

    A number of diseases are caused by faulty function of the cardiac pacemaker and described as "sick sinus syndrome". The medical treatment of sick sinus syndrome with electrical pacemaker implants in the diseased heart includes risks. These problems may be overcome via "biological pacemaker" derived from different adult cardiac cells or pluripotent stem cells. The generation of cardiac pacemaker cells requires the understanding of the pacing automaticity. Two characteristic phenomena the "membrane-clock" and the "Ca(2+)-clock" are responsible for the modulation of the pacemaker activity. Processes in the "membrane-clock" generating the spontaneous pacemaker firing are based on the voltage-sensitive membrane ion channel activity starting with slow diastolic depolarization and discharging in the action potential. The influence of the intracellular Ca(2+) modulating the pacemaker activity is characterized by the "Ca(2+)-clock". The generation of pacemaker cells started with the reprogramming of adult cardiac cells by targeted induction of one pacemaker function like HCN1-4 overexpression and enclosed in an activation of single pacemaker specific transcription factors. Reprogramming of adult cardiac cells with the transcription factor Tbx18 created cardiac cells with characteristic features of cardiac pacemaker cells. Another key transcription factor is Tbx3 specifically expressed in the cardiac conduction system including the sinoatrial node and sufficient for the induction of the cardiac pacemaker gene program. For a successful cell therapeutic practice, the generated cells should have all regulating mechanisms of cardiac pacemaker cells. Otherwise, the generated pacemaker cells serve only as investigating model for the fundamental research or as drug testing model for new antiarrhythmics. This article is part of a Special Issue entitled: Cardiomyocyte Biology: Integration of Developmental and Environmental Cues in the Heart edited by Marcus Schaub and Hughes Abriel.

  4. Dental treatment in patients with cardiac pacemakers: Is it a risky affair?

    Directory of Open Access Journals (Sweden)

    Reet Kamal

    2016-01-01

    Full Text Available Cardiac pacemakers are the implanted devices used to treat patients with damaged heart muscles. These electronic devices are sensitive to strong electromagnetic signals. The dental literature also included articles regarding electromagnetic interferences to pacemakers, due to dental devices such as ultrasonic scalers, electrosurgical unit, ultrasonic bath cleaners, and battery driven light cure composite unit. Although pacemakers of new generation have more protective features than those of past, but still precautionary measures should be taken in dental clinics for the safety of cardiac patients with pacemaker. The aim of this paper is to identify the possible sources from dental clinics which can adversely interfere with the pacemaker activity and to provide some guidelines for safe dental practice in this high-risk group.

  5. Permanent cardiac pacemaker in infants and children.

    Science.gov (United States)

    Dasmahapatra, H K; Jamieson, M P; Brewster, G M; Doig, B; Pollock, J C

    1986-08-01

    Between October 1970 and November 1984, 26 infants and children aged 11 days to 18 years (mean 5.7 years) received 42 permanent cardiac pacemakers (26 primary implants, 16 re-implants) for congenital or surgically acquired heart block, bradycardia and sinus node dysfunction. Twenty-two patients had unipolar pacing and 4 bipolar pacing. Of 26 primary implantations, 2 had fixed rate epicardial pacing, 16 ventricular demand pacing (13 epicardial, 3 endocardial), 3 epicardial VAT (P-synchronous) pacing and 5 DDD (universal) pacing (4 epicardial, one endocardial). Fourteen patients required a further 19 operations for change of generators (16), ventricular lead (1), generator site (1) and generator encasing (1). Thirty-day hospital mortality was 11.5% (3/26), of which one death was possibly related to pacing failure. Four patients died during the follow-up period (3 months to 10 years; mean 3.4 years). Sixteen of the 19 survivors achieved complete symptomatic relief, without any medical therapy. Our results indicate that modern cardiac pacemaker systems are safe and reliable, and are associated with major relief of symptoms in this age group.

  6. Modern perspectives on numerical modeling of cardiac pacemaker cell.

    Science.gov (United States)

    Maltsev, Victor A; Yaniv, Yael; Maltsev, Anna V; Stern, Michael D; Lakatta, Edward G

    2014-01-01

    Cardiac pacemaking is a complex phenomenon that is still not completely understood. Together with experimental studies, numerical modeling has been traditionally used to acquire mechanistic insights in this research area. This review summarizes the present state of numerical modeling of the cardiac pacemaker, including approaches to resolve present paradoxes and controversies. Specifically we discuss the requirement for realistic modeling to consider symmetrical importance of both intracellular and cell membrane processes (within a recent "coupled-clock" theory). Promising future developments of the complex pacemaker system models include the introduction of local calcium control, mitochondria function, and biochemical regulation of protein phosphorylation and cAMP production. Modern numerical and theoretical methods such as multi-parameter sensitivity analyses within extended populations of models and bifurcation analyses are also important for the definition of the most realistic parameters that describe a robust, yet simultaneously flexible operation of the coupled-clock pacemaker cell system. The systems approach to exploring cardiac pacemaker function will guide development of new therapies such as biological pacemakers for treating insufficient cardiac pacemaker function that becomes especially prevalent with advancing age.

  7. Design and Implementation of programmable Cardiac Pacemaker Using VHDL

    Directory of Open Access Journals (Sweden)

    Omkar Dwivedi

    2015-05-01

    Full Text Available Pacemaker design has evolved very rapidly over the last several years. There has been a great deal of work in enhancing the programmability of pacemakers, to enable them to be programmed to work with different selected operating parameters, and indeed to work in different modes. In Taiwan, about 70%of cardiac pacemakerpatients are paced only from the ventricle with some pacing parameter programmability. This paper goal is to design a cardiac pacemaker with various NBG modes. A state machine approach has been followed to achieve the desired purpose. The pacemaker system is divide into three main sections i.e. controlling unit, sensing unit and pulse generator. In this paper we mainly concentrate on controlling unit and pulse generator. It has been developed using VHDL coding and implemented in hardware using FPGA. In a simple pacemaker process i.e. single chamber or dual chamber pacemaker, first an input signal or an event is detected in heart through leads. When the input signal is detected a timer generates a delay for approximately 0.8 sec. It is the time between two consecutive heartbeats, thus giving us 72 heartbeats per minute. Once the generated delay expires, sensing unit again start detecting a new event. If any event is detected we repeat the process of detection and waiting. If no event is detected we need to provide an electrical pulse to the heart and then repeat the whole process of detection and waiting. The code has been optimized and modified for different pacemaker modes.

  8. Acute pericarditis with cardiac tamponade induced by pacemaker implantation.

    Science.gov (United States)

    Shingaki, Masami; Kobayashi, Yutaka; Suzuki, Haruo

    2015-11-01

    An 87-year-old woman was diagnosed with third-degree atrioventricular block and underwent pacemaker implantation. On postoperative day 12, she experienced cardiac tamponade that was suspected on computed tomography to be caused by lead perforation; therefore, we performed open-heart surgery. However, we could not identify a perforation site on the heart, and drained a 400-mL exudative pericardial effusion. Subsequently, we diagnosed the pericardial effusion as due to pericarditis induced by pacemaker implantation. It is sometimes difficult to distinguish pericarditis from pacemaker lead perforation, so both should be included in the differential diagnosis.

  9. Self-powered cardiac pacemaker enabled by flexible single crystalline PMN-PT piezoelectric energy harvester.

    Science.gov (United States)

    Hwang, Geon-Tae; Park, Hyewon; Lee, Jeong-Ho; Oh, SeKwon; Park, Kwi-Il; Byun, Myunghwan; Park, Hyelim; Ahn, Gun; Jeong, Chang Kyu; No, Kwangsoo; Kwon, HyukSang; Lee, Sang-Goo; Joung, Boyoung; Lee, Keon Jae

    2014-07-23

    A flexible single-crystalline PMN-PT piezoelectric energy harvester is demonstrated to achieve a self-powered artificial cardiac pacemaker. The energy-harvesting device generates a short-circuit current of 0.223 mA and an open-circuit voltage of 8.2 V, which are enough not only to meet the standard for charging commercial batteries but also for stimulating the heart without an external power source.

  10. Identification and functional characterization of cardiac pacemaker cells in zebrafish.

    Directory of Open Access Journals (Sweden)

    Federico Tessadori

    Full Text Available In the mammalian heart a conduction system of nodes and conducting cells generates and transduces the electrical signals evoking myocardial contractions. Specialized pacemaker cells initiating and controlling cardiac contraction rhythmicity are localized in an anatomically identifiable structure of myocardial origin, the sinus node. We previously showed that in mammalian embryos sinus node cells originate from cardiac progenitors expressing the transcription factors T-box transcription factor 3 (Tbx3 and Islet-1 (Isl1. Although cardiac development and function are strikingly conserved amongst animal classes, in lower vertebrates neither structural nor molecular distinguishable components of a conduction system have been identified, questioning its evolutionary origin. Here we show that zebrafish embryos lacking the LIM/homeodomain-containing transcription factor Isl1 display heart rate defects related to pacemaker dysfunction. Moreover, 3D reconstructions of gene expression patterns in the embryonic and adult zebrafish heart led us to uncover a previously unidentified, Isl1-positive and Tbx2b-positive region in the myocardium at the junction of the sinus venosus and atrium. Through their long interconnecting cellular protrusions the identified Isl1-positive cells form a ring-shaped structure. In vivo labeling of the Isl1-positive cells by transgenic technology allowed their isolation and electrophysiological characterization, revealing their unique pacemaker activity. In conclusion we demonstrate that Isl1-expressing cells, organized as a ring-shaped structure around the venous pole, hold the pacemaker function in the adult zebrafish heart. We have thereby identified an evolutionary conserved, structural and molecular distinguishable component of the cardiac conduction system in a lower vertebrate.

  11. Reuse of pacemakers, defibrillators and cardiac resynchronisation devices

    Science.gov (United States)

    Sakthivel, R; Satheesh, Santhosh; Ananthakrishna Pillai, Ajith; Sagnol, Pascal; Jouven, Xavier; Dodinot, Bernard; Balachander, Jayaraman

    2017-01-01

    Objective Access to pacemakers remains poor among many patients in low/middle-income countries. Reuse of explanted pacemakers is a possible solution, but is still not widespread because of concerns regarding outcomes, especially infection. Our objective was to study early outcomes with implants using reused devices and compare them with those with implants using new devices. Methods We studied all patients who underwent implantation of a new or reused pacemaker, cardiac resynchronisation therapy (CRT) device or implantable cardioverter defibrillator (ICD) in the last 5 years at a single institution. We analysed outcomes related to infection, device malfunction and device-related death within 6 months after initial implantation. Results During the study period, 887 patients underwent device implant, including 127 CRT devices or ICDs. Of these, 260 devices (29.3%) were reused and the others were new. At 6 months, there were three device-related infections in implants using a new device. There were no infections among patients receiving a reused device. There were no device malfunctions or device-related deaths in either group. Conclusions We found no difference in rate of infection or device malfunction among patients getting a reused device as compared with those with a new device. This study reinforces the safety of reusing devices for implant including CRT and ICDs. PMID:28176981

  12. Rechargeable silver-modified mercuric oxide-zinc cell for cardiac pacemakers.

    Science.gov (United States)

    Tyers, G F; Hughes, H C; Brownlee, R R; Manley, N J; Gorman, I N

    1976-11-04

    Tests were conducted on rechargeable mercury-zinc pacemaker batteries under simulated and actual biologic conditions, using a variety of discharge rates and charging schedules. In tests on 96 cells at a 6.4 milliampere (ma) discharge, recharging once every 15 months of simulated pacing at a 25 microampere (mua) drain, the earliest cell failure occurred after an equivalent of 50 years of pacing. The mean pacing equivalent for all 96 cells was more than 140 years. In 6.4 ma discharge tests on 24 cells, recharging once every 8 days of simulated pacing, only 1 cell in 24 failed after an equivalent of more than 500 years of pacing (actual time 2 years). In tests on 13 cells pacing at a 200 mua drain without recharging, the simulated mean duration of pacing before total discharge was 4.8 years. Seven other cells at a 200 mua drain with periodic recharging continue to function normally after more than 7 years of actual time, simulating 56 years of pacing at a 25 mua drain. Cardiac pacemakers using the rechargeable mercury-zinc cell have been implanted in animals for more than 2 1/2 years and in patients for more than 1 year with all units continuing to function satisfactorily. It has been demonstrated unequivocally that a rechargeable mercury-zinc pacemaker will function continuously for more than 4 years without recharging and that periodic recharging will extend pacing life far beyond that predicted for lithium and nuclear primary power sources.

  13. Is the gated blood pool scan useful for optimization of programmable cardiac pacemakers

    Energy Technology Data Exchange (ETDEWEB)

    Gunkel, H.; Otto, H.J.; Pundrich, R.; Mann, D.

    1986-08-01

    The significance of the ECG-triggered cardiac blood pool scan for optimization of physiological parameters of multiprogrammable cardiac pacemakers was investigated. Six patients were investigated, and two case reports are demonstrated in detail. By use of the quantitative evaluation of the parametric scans and other function parameters it is possible to evaluate cardiac function objectively in relation to the stimulation frequency and AV-delay using demand/delay pacemakers. These first results encourage the further use of this technique for evaluation of cardiac function in patients with programmable pacemakers.

  14. Hardware-in-the-loop simulation and energy optimization of cardiac pacemakers.

    Science.gov (United States)

    Barker, Chris; Kwiatkowska, Marta; Mereacre, Alexandru; Paoletti, Nicola; Patane, Andrea

    2015-01-01

    Implantable cardiac pacemakers are medical devices that can monitor and correct abnormal heart rhythms. To provide the necessary safety assurance for pacemaker software, both testing and verification of the code, as well as testing the entire pacemaker hardware in the loop, is necessary. In this paper, we present a hardware testbed that enables detailed hardware-in-the-loop simulation and energy optimisation of pacemaker algorithms with respect to a heart model. Both the heart and the pacemaker models are encoded in Simulink/Stateflow™ and translated into executable code, with the pacemaker executed directly on the microcontroller. We evaluate the usefulness of the testbed by developing a parameter synthesis algorithm which optimises the timing parameters based on power measurements acquired in real-time. The experiments performed on real measurements successfully demonstrate that the testbed is capable of energy minimisation in real-time and obtains safe pacemaker timing parameters.

  15. Excitation model of pacemaker cardiomyocytes of cardiac conduction system

    Science.gov (United States)

    Grigoriev, M.; Babich, L.

    2015-11-01

    Myocardium includes typical and atypical cardiomyocytes - pacemakers, which form the cardiac conduction system. Excitation from the atrioventricular node in normal conditions is possible only in one direction. Retrograde direction of pulses is impossible. The most important prerequisite for the work of cardiomyocytes is the anatomical integrity of the conduction system. Changes in contractile force of the cardiomyocytes, which appear periodically, are due to two mechanisms of self-regulation - heterometric and homeometric. Graphic course of the excitation pulse propagation along the heart muscle more accurately reveals the understanding of the arrhythmia mechanism. These models have the ability to visualize the essence of excitation dynamics. However, they do not have the proper forecasting function for result estimation. Integrative mathematical model enables further investigation of general laws of the myocardium active behavior, allows for determination of the violation mechanism of electrical and contractile function of cardiomyocytes. Currently, there is no full understanding of the topography of pacemakers and ionic mechanisms. There is a need for the development of direction of mathematical modeling and comparative studies of the electrophysiological arrangement of cells of atrioventricular connection and ventricular conduction system.

  16. Management of radiation therapy patients with cardiac defibrillator or pacemaker.

    Science.gov (United States)

    Salerno, Francesca; Gomellini, Sara; Caruso, Cristina; Barbara, Raffaele; Musio, Daniela; Coppi, Tamara; Cardinale, Mario; Tombolini, Vincenzo; de Paula, Ugo

    2016-06-01

    The increasing growth of population with cardiac implantable electronic devices (CIEDs) such as Pacemaker (PM) and Implantable Cardiac Defibrillators (ICD), requires particular attention in management of patients needing radiation treatment. This paper updates and summarizes some recommendations from different international guidelines. Ionizing radiation and/or electromagnetic interferences could cause device failure. Current approaches to treatment in patients who have these devices vary among radiation oncology centres. We refer to the German Society of Radiation Oncology and Cardiology guidelines (ed. 2015); to the Society of Cardiology Australia and New Zealand Statement (ed. 2015); to the guidelines in force in the Netherlands (ed. 2012) and to the Italian Association of Radiation Oncology recommendations (ed. 2013) as reported in the guidelines for the treatment of breast cancer in patients with CIED. Although there is not a clear cut-off point, risk of device failure increases with increasing doses. Cumulative dose and pacing dependency have been combined to categorize patients into low-, medium- and high-risk groups. Measures to secure patient safety are described for each category. The use of energy ≤6MV is preferable and it's strongly recommended not to exceed a total dose of 2 Gy to the PM and 1 Gy for ICD. Given the dangers of device malfunction, radiation oncology departments should adopt all the measures designed to minimize the risk to patients. For this reason, a close collaboration between cardiologist, radiotherapist and physicist is necessary.

  17. Popeye domain-containing proteins and stress-mediated modulation of cardiac pacemaking.

    Science.gov (United States)

    Simrick, Subreena; Schindler, Roland F; Poon, Kar-Lai; Brand, Thomas

    2013-10-01

    An intricate network of ion channels and pumps are involved in generating a diastolic pacemaker potential, which is transmitted to the working myocardium with the help of the cardiac conduction system. The principles of cardiac pacemaking are reasonably well understood, however, the mechanism by which the heart increases its beating frequency in response to adrenergic stimulation has not been fully worked out. The Popeye domain-containing (Popdc) genes encode plasma membrane-localized proteins that are able to bind cAMP with high affinity; mice with null mutations in Popdc1 or 2 have a stress-induced pacemaker dysfunction. The phenotype in both mutants develops in an age-dependent manner and thus may model pacemaker dysfunction in man, as well as provide novel mechanistic insights into the process of pacemaker adaptation to stress.

  18. A fully implantable pacemaker for the mouse: from battery to wireless power.

    Directory of Open Access Journals (Sweden)

    Jacob I Laughner

    Full Text Available Animal models have become a popular platform for the investigation of the molecular and systemic mechanisms of pathological cardiovascular physiology. Chronic pacing studies with implantable pacemakers in large animals have led to useful models of heart failure and atrial fibrillation. Unfortunately, molecular and genetic studies in these large animal models are often prohibitively expensive or not available. Conversely, the mouse is an excellent species for studying molecular mechanisms of cardiovascular disease through genetic engineering. However, the large size of available pacemakers does not lend itself to chronic pacing in mice. Here, we present the design for a novel, fully implantable wireless-powered pacemaker for mice capable of long-term (>30 days pacing. This design is compared to a traditional battery-powered pacemaker to demonstrate critical advantages achieved through wireless inductive power transfer and control. Battery-powered and wireless-powered pacemakers were fabricated from standard electronic components in our laboratory. Mice (n = 24 were implanted with endocardial, battery-powered devices (n = 14 and epicardial, wireless-powered devices (n = 10. Wireless-powered devices were associated with reduced implant mortality and more reliable device function compared to battery-powered devices. Eight of 14 (57.1% mice implanted with battery-powered pacemakers died following device implantation compared to 1 of 10 (10% mice implanted with wireless-powered pacemakers. Moreover, device function was achieved for 30 days with the wireless-powered device compared to 6 days with the battery-powered device. The wireless-powered pacemaker system presented herein will allow electrophysiology studies in numerous genetically engineered mouse models as well as rapid pacing-induced heart failure and atrial arrhythmia in mice.

  19. Simple hand-held metal detectors are an effective means of detecting cardiac pacemakers in the deceased prior to cremation.

    Science.gov (United States)

    Stone, Jason Lyle; Williams, John; Fearn, Lesley

    2010-05-01

    The hazard of undetected cardiac pacemakers exploding in crematoria is well described. This short report describes the use of an affordable hand-held metal detector to detect cardiac pacemakers. Over the course of a year, the metal detector located 100% of cardiac pacemakers in a district general hospital mortuary. A simple model using pigskin and fat is also used to demonstrate the effectiveness in vitro. Commercially purchased hand-held metal detectors should be used in all mortuaries responsible for detection and removal of cardiac pacemakers prior to cremation.

  20. The National Survey of Cardiac Pacemakers and Cardioverter Defibrillators

    Directory of Open Access Journals (Sweden)

    Gholamrerza Shafieian

    2006-07-01

    Full Text Available Background: Permanent pacemakers provide effective relief of symptoms and are life-saving in patients with symptomatic heart block. Implantable cardioverter defibrillators (ICD are also increasingly recognized as life-saving tools in various groups of patients with malignant ventricular tachyarrhythmias. Methods: As part of the “world survey on pacemaker and ICD implantations”, a survey of all device implantations in Iran during the year 2001 was performed. Data was collected and cross-checked through three sources i.e. direct contact with implanting physicians, pacemaker companies and the governmental pacemaker distributing body.Results: During the year studied, 1635 patients received permanent pacemakers. 88% were new implants at an estimated rate of 24 per million population. The mean age of patients was 65 years and 56.2% were male. 40 cardiologists and 19 surgeons implanted the pacemakers at 27 centers throughout the country. Complete heart block was consistently the most common indication at all centers (mean 56.1%, sick sinus syndrome being the next most common one (mean 20.8%. 69% of the pacemakers were single chamber pacemakers. Transvenous insertion of bipolar steroid-eluting passive fixation leads was the predominant practice at most centers. A total of 60 ICDs were implanted at 7 centers by 9 cardiologists. 45% of ICD implants were dual chamber devices.Conclusion: The survey is the only one available right now and provides useful information about the prevailing pacemaker and defibrillator implantation practice in Iran. Future surveys would be facilitated if a standardized implant registry such as that used in Europe were established in this country.

  1. Pacemaker optimization guided by echocardiography in cardiac resynchronization therapy

    Directory of Open Access Journals (Sweden)

    Trifunović Danijela

    2009-01-01

    Full Text Available Introduction. Cardiac resynchronization therapy (CRT or biventricular pacing is a contemporary treatment in the management of advanced heart failure. Echocardiography plays an evolving and important role in patient selection for CRT, follow-up of acute and chronic CRT effects and optimization of device settings after biventricular pacemaker implantation. In this paper we illustrate usefulness of echocardiography for successful AV and VV timing optimization in patients with CRT. A review of up-to-date literature concerning rationale for AV and VV delay optimization, echocardiographic protocols and current recommendations for AV and VV optimization after CRT are also presented. Outline of Cases. The first case is of successful AV delay optimization guided by echocardiography in a patient with dilated cardiomyopathy treated with CRT is presented. Pulsed blood flow Doppler was used to detect mitral inflow while programming different duration of AV delay. The AV delay with optimal transmittal flow was established. The optimal mitral flow was the one with clearly defined E and A waves and maximal velocity time integral (VTI of the mitral flow. Improvement in clinical status and reverse left ventricle remodelling with improvement of ejection fraction was registered in our patient after a month. The second case presents a patient with heart failure caused by dilated cardiomyopathy; six months after CRT implantation the patient was still NYHA class III and with a significantly depressed left ventricular ejection fraction. Optimization of VV interval guided by echocardiography was undertaken measuring VTI of the left ventricular outflow tract (LVOT during programming of different VV intervals. The optimal VV interval was determined using a maximal LVOT VTI. A month after VV optimization our patient showed improvement in LV ejection fraction. Conclusion. Optimal management of patients treated with CRT integrate both clinical and echocardiographic follow

  2. Capsule endoscopy in patients with cardiac pacemakers, implantable cardioverter defibrillators and left heart assist devices.

    Science.gov (United States)

    Bandorski, Dirk; Höltgen, Reinhard; Stunder, Dominik; Keuchel, Martin

    2014-01-01

    According to the recommendations of the US Food and Drug Administration and manufacturers, capsule endoscopy should not be used in patients carrying implanted cardiac devices. For this review we considered studies indexed (until 30.06.2013) in Medline [keywords: capsule endoscopy, small bowel endoscopy, cardiac pacemaker, implantable cardioverter defibrillator, interference, left heart assist device], technical information from Given Imaging and one own publication (not listed in Medline). Several in vitro and in vivo studies included patients with implanted cardiac devices who underwent capsule endoscopy. No clinically relevant interference was noticed. Initial reports on interference with a simulating device were not reproduced. Furthermore technical data of PillCam (Given Imaging) demonstrate that the maximum transmission power is below the permitted limits for cardiac devices. Hence, impairment of cardiac pacemaker, defibrillator or left ventricular heart assist device function by capsule endoscopy is not expected. However, wireless telemetry can cause dysfunction of capsule endoscopy recording. Application of capsule endoscopy is feasible and safe in patients with implanted cardiac devices such as pacemakers, cardioverter defibrillators, and left heart assist devices. Development of new technologies warrants future re-evaluation.

  3. Popeye domain containing proteins are essential for stress-mediated modulation of cardiac pacemaking in mice.

    Science.gov (United States)

    Froese, Alexander; Breher, Stephanie S; Waldeyer, Christoph; Schindler, Roland F R; Nikolaev, Viacheslav O; Rinné, Susanne; Wischmeyer, Erhard; Schlueter, Jan; Becher, Jan; Simrick, Subreena; Vauti, Franz; Kuhtz, Juliane; Meister, Patrick; Kreissl, Sonja; Torlopp, Angela; Liebig, Sonja K; Laakmann, Sandra; Müller, Thomas D; Neumann, Joachim; Stieber, Juliane; Ludwig, Andreas; Maier, Sebastian K; Decher, Niels; Arnold, Hans-Henning; Kirchhof, Paulus; Fabritz, Larissa; Brand, Thomas

    2012-03-01

    Cardiac pacemaker cells create rhythmic pulses that control heart rate; pacemaker dysfunction is a prevalent disorder in the elderly, but little is known about the underlying molecular causes. Popeye domain containing (Popdc) genes encode membrane proteins with high expression levels in cardiac myocytes and specifically in the cardiac pacemaking and conduction system. Here, we report the phenotypic analysis of mice deficient in Popdc1 or Popdc2. ECG analysis revealed severe sinus node dysfunction when freely roaming mutant animals were subjected to physical or mental stress. In both mutants, bradyarrhythmia developed in an age-dependent manner. Furthermore, we found that the conserved Popeye domain functioned as a high-affinity cAMP-binding site. Popdc proteins interacted with the potassium channel TREK-1, which led to increased cell surface expression and enhanced current density, both of which were negatively modulated by cAMP. These data indicate that Popdc proteins have an important regulatory function in heart rate dynamics that is mediated, at least in part, through cAMP binding. Mice with mutant Popdc1 and Popdc2 alleles are therefore useful models for the dissection of the mechanisms causing pacemaker dysfunction and could aid in the development of strategies for therapeutic intervention.

  4. Improved quality of life after treatment of prolonged asystole during breath holding spells with a cardiac pacemaker

    Directory of Open Access Journals (Sweden)

    Bruno Kolterer

    2015-01-01

    Conclusion: Cardiac pacing using appropriate pacemaker settings seems effective in the prevention of LOC and reduction of the frequency of BHS. Our results imply a reduction of subjective stress levels of patients and parents as well as an increased quality of everyday life. After all, randomized controlled trials of the influence of cardiac pacemaker implantation on subjective stress levels in patients with BHS are needed.

  5. [Interferences and cardiac pacemakers--defibrillators. Results of in vivo experiments and radio frequencies].

    Science.gov (United States)

    Trigano, J A

    2003-04-01

    Interference with cardiac pacemakers and defibrillators by cellular phone and electronic article surveillance systems is shown in experimental studies with disparate findings. Interaction occurrence in real life is a convincing but rare experience. Device model, distance, power output and technology of the source are different and sometimes uncontrollable factors. As a result it remains difficult to quantify the true incidence of interaction and associated health risk. Nevertheless, simple recommendations commonly help the patients to prevent the interference.

  6. Prevalence of sleep-disordered breathing in elderly patients with cardiac pacemaker: a case-control study

    Institute of Scientific and Technical Information of China (English)

    Haiyun WU; Shiwen WANG; Jianping JIA; Wenli ZHANG; Qiang XU

    2005-01-01

    Objective To investigate the prevalence of sleep-disordered breathing in elderly patients with permanent cardiac pacemaker implantation due to bradyarrhythmias, and the relationship between pacing mode and patients' sleep apnea-hypopnea index.Methods Forty-four elderly patients (>60 years) with cardiac pacemaker and their 44 controls matched for gender, age, body mass index and cardiovascular morbidity were studied using polysomnography or portable sleep monitoring device. Results Prevalence of sleep-disordered breathing (apnea-hypopnea index ≥5/h) was 44.7% and the mean apnea-hypopnea index was 8.2 ±4.1/h in the cardiac pacemaker group, which were significantly higher than those in control subjects (25% and 4.6±2.4/h, respectively, P<0.01 and P<0.05). The mean apnea-hypopnea index of patients with DDD or AAI pacemaker was significantly lower than that of patients with VVI pacemaker. Conclusions Sleep-disordered breathing was more common in patients who had their cardiac pacemaker implanted due to bradyarrhythmias than in their matched controls. Compared with VVI pacing, DDD or AAI pacing may be more beneficial to patients with bradyarrhythmias and sleep-disordered breathing.

  7. Cardiorespiratory Mechanical Simulator for In Vitro Testing of Impedance Minute Ventilation Sensors in Cardiac Pacemakers.

    Science.gov (United States)

    Marcelli, Emanuela; Cercenelli, Laura

    2016-01-01

    We developed a cardiorespiratory mechanical simulator (CRMS), a system able to reproduce both the cardiac and respiratory movements, intended to be used for in vitro testing of impedance minute ventilation (iMV) sensors in cardiac pacemakers. The simulator consists of two actuators anchored to a human thorax model and a software interface to control the actuators and to acquire/process impedance signals. The actuators can be driven separately or simultaneously to reproduce the cardiac longitudinal shortening at a programmable heart rate and the diaphragm displacement at a programmable respiratory rate (RR). A standard bipolar pacing lead moving with the actuators and a pacemaker case fixed to the thorax model have been used to measure impedance (Z) variations during the simulated cardiorespiratory movements. The software is able to discriminate the low-frequency component because of respiration (Z(R)) from the high-frequency ripple because of cardiac effect (Z(C)). Impedance minute ventilation is continuously calculated from Z(R) and RR. From preliminary tests, the CRMS proved to be a reliable simulator for in vitro evaluation of iMV sensors. Respiration impedance recordings collected during cardiorespiratory movements reproduced by the CRMS were comparable in morphology and amplitude with in vivo assessments of transthoracic impedance variations.

  8. Cancer patients with cardiac pacemakers needing radiation treatment: A systematic review

    Directory of Open Access Journals (Sweden)

    Anusheel Munshi

    2013-01-01

    Full Text Available With improving average life expectancy of individuals in most countries, there has been increase in the incidence of cardiovascular diseases and cancers. Radiation oncologists therefore are likely to encounter an increasing number of cancer patients with in situ cardiac pacemaker devices needing radiation treatments. Pacemaker technology has advanced rapidly in recent years. As a result, the potential interactions of these devices with radiation therapy have changed since American Association of Physicists in Medicine (AAPM issued guidelines in 1994. Current approaches to treatment in patients who have these devices vary among radiation oncology centers. Furthermore, the recommendations given by the devices′ manufacturers differ considerably. Common knowledge about pacemaker in radiation oncology community is vital as radiation management needs to be tailored to individual patients in accordance to the information of available for the device. Some general practical guidelines can be gleaned from the literature. It is felt that more robust information is required using web based database sharing to develop total safe practice guidelines in such patients. This article reviews the information available to help create such guidelines and presents recommendations for treatment in this increasingly common clinical situation.

  9. Pheochromocytoma-induced atrial tachycardia leading to cardiogenic shock and cardiac arrest: resolution with atrioventricular node ablation and pacemaker placement.

    Science.gov (United States)

    Shawa, Hassan; Bajaj, Mandeep; Cunningham, Glenn R

    2014-12-01

    Pheochromocytoma should be considered in young patients who have acute cardiac decompensation, even if they have no history of hypertension. Atrioventricular node ablation and pacemaker placement should be considered for stabilizing pheochromocytoma patients with cardiogenic shock due to atrial tachyarrhythmias. A 38-year-old black woman presented with cardiogenic shock (left ventricular ejection fraction, cardiogenic shock and cardiac arrest unresolved by the placement of 2 different ventricular assist devices, but that was completely reversed by radiofrequency ablation of the atrioventricular node and the placement of a temporary pacemaker. We present the patient's clinical, laboratory, and imaging findings, and we review the relevant literature.

  10. How Does a Pacemaker Work?

    Science.gov (United States)

    ... a battery, a computerized generator, and wires with sensors at their tips. (The sensors are called electrodes.) The battery powers the generator, ... or single-chamber, pacemaker in the upper chest. Types of Pacemaker Programming The two main types of ...

  11. Genetically engineered cardiac pacemaker: Stem cells transfected with HCN2 gene and myocytes—A model

    Science.gov (United States)

    Kanani, S.; Pumir, A.; Krinsky, V.

    2008-01-01

    One of the successfully tested methods to design genetically engineered cardiac pacemaker cells consists in transfecting a human mesenchymal stem cell (hMSC) with a HCN2 gene and connecting it to a myocyte. We develop and study a mathematical model, describing a myocyte connected to a hMSC transfected with a HCN2 gene. The cardiac action potential is described both with the simple Beeler Reuter model, as well as with the elaborate dynamic Luo Rudy model. The HCN2 channel is described by fitting electrophysiological records, in the spirit of Hodgkin Huxley. The model shows that oscillations can occur in a pair myocyte-stem cell, that was not observed in the experiments yet. The model predicted that: (1) HCN pacemaker channels can induce oscillations only if the number of expressed I channels is low enough. At too high an expression level of I channels, oscillations cannot be induced, no matter how many pacemaker channels are expressed. (2) At low expression levels of I channels, a large domain of values in the parameter space (n, N) exists, where oscillations should be observed. We denote N the number of expressed pacemaker channels in the stem cell, and n the number of gap junction channels coupling the stem cell and the myocyte. (3) The expression levels of I channels observed in ventricular myocytes, both in the Beeler Reuter and in the dynamic Luo Rudy models are too high to allow to observe oscillations. With expression levels below ˜1/4 of the original value, oscillations can be observed. The main consequence of this work is that in order to obtain oscillations in an experiment with a myocyte-stem cell pair, increasing the values of n, N is unlikely to be helpful, unless the expression level of I has been reduced enough. The model also allows us to explore levels of gene expression not yet achieved in experiments, and could be useful to plan new experiments, aimed at improving the robustness of the oscillations.

  12. Genetically engineered cardiac pacemaker: Stem cells transfected with HCN2 gene and myocytes-A model

    Energy Technology Data Exchange (ETDEWEB)

    Kanani, S. [Institut Genomique Fonctionelle, 141 Rue de la Cardonille, 34396 Montpellier (France); Institut Non Lineaire de Nice, CNRS and Universite de Nice, 1361 route des Lucioles, 06560 Valbonne (France); Pumir, A. [Institut Non Lineaire de Nice, CNRS and Universite de Nice, 1361 route des Lucioles, 06560 Valbonne (France); Laboratoire J.A. Dieudonne, CNRS and Universite de Nice, Parc Valrose, 06108 Nice (France)], E-mail: alain.pumir@unice.fr; Krinsky, V. [Institut Non Lineaire de Nice, CNRS and Universite de Nice, 1361 route des Lucioles, 06560 Valbonne (France)

    2008-01-07

    One of the successfully tested methods to design genetically engineered cardiac pacemaker cells consists in transfecting a human mesenchymal stem cell (hMSC) with a HCN2 gene and connecting it to a myocyte. We develop and study a mathematical model, describing a myocyte connected to a hMSC transfected with a HCN2 gene. The cardiac action potential is described both with the simple Beeler-Reuter model, as well as with the elaborate dynamic Luo-Rudy model. The HCN2 channel is described by fitting electrophysiological records, in the spirit of Hodgkin-Huxley. The model shows that oscillations can occur in a pair myocyte-stem cell, that was not observed in the experiments yet. The model predicted that: (1) HCN pacemaker channels can induce oscillations only if the number of expressed I{sub K1} channels is low enough. At too high an expression level of I{sub K1} channels, oscillations cannot be induced, no matter how many pacemaker channels are expressed. (2) At low expression levels of I{sub K1} channels, a large domain of values in the parameter space (n, N) exists, where oscillations should be observed. We denote N the number of expressed pacemaker channels in the stem cell, and n the number of gap junction channels coupling the stem cell and the myocyte. (3) The expression levels of I{sub K1} channels observed in ventricular myocytes, both in the Beeler-Reuter and in the dynamic Luo-Rudy models are too high to allow to observe oscillations. With expression levels below {approx}1/4 of the original value, oscillations can be observed. The main consequence of this work is that in order to obtain oscillations in an experiment with a myocyte-stem cell pair, increasing the values of n, N is unlikely to be helpful, unless the expression level of I{sub K1} has been reduced enough. The model also allows us to explore levels of gene expression not yet achieved in experiments, and could be useful to plan new experiments, aimed at improving the robustness of the oscillations.

  13. Subclavian Vein Stenosis/Occlusion Following Transvenous Cardiac Pacemaker and Defibrillator Implantation: Incidence, Pathophysiology and Current Management

    Directory of Open Access Journals (Sweden)

    Brian O'Leary

    2015-08-01

    Full Text Available Subclavian vein stenosis is a common, but usually asymptomatic, complication following cardiac device placement. In addition to reviewing the literature on incidence, pathogenesis and management options for this important clinical problem, we describe two cases of symptomatic subclavian vein occlusion following pacemaker/defibrillator placement and successful treatment with venoplasty and stenting.

  14. Inhomogeneity of action potential waveshape assists frequency entrainment of cardiac pacemaker cells.

    Science.gov (United States)

    Cloherty, S L; Lovell, N H; Celler, B G; Dokos, S

    2001-10-01

    In this paper, we have employed ionic models of sinoatrial node cells to investigate the synchronization of a pair of coupled cardiac pacemaker cells from central and peripheral regions of the sinoatrial node. The free-running cycle length of the cell models was perturbed using two independent techniques and the minimum coupling conductance required to achieve frequency entrainment was used to assess the relative ease with which various cell pairs achieve entrainment. The factors effecting entrainment were further investigated using single-cell models paced with an artificial biphasic coupling current. Our simulation results suggest that dissimilar cell types, those with largely different upstroke velocities entrain more easily, that is, they require less coupling conductance to achieve 1:1 frequency entrainment. We, therefore, propose that regional variation in action-potential waveshape within the sinoatrial node assists frequency synchronization in vivo.

  15. Design of wavelet-based ECG detector for implantable cardiac pacemakers.

    Science.gov (United States)

    Min, Young-Jae; Kim, Hoon-Ki; Kang, Yu-Ri; Kim, Gil-Su; Park, Jongsun; Kim, Soo-Won

    2013-08-01

    A wavelet Electrocardiogram (ECG) detector for low-power implantable cardiac pacemakers is presented in this paper. The proposed wavelet-based ECG detector consists of a wavelet decomposer with wavelet filter banks, a QRS complex detector of hypothesis testing with wavelet-demodulated ECG signals, and a noise detector with zero-crossing points. In order to achieve high detection accuracy with low power consumption, a multi-scaled product algorithm and soft-threshold algorithm are efficiently exploited in our ECG detector implementation. Our algorithmic and architectural level approaches have been implemented and fabricated in a standard 0.35 μm CMOS technology. The testchip including a low-power analog-to-digital converter (ADC) shows a low detection error-rate of 0.196% and low power consumption of 19.02 μW with a 3 V supply voltage.

  16. Global Bifurcation Structure and Variability of Pacemaker Rhythm in a Detailed Model of Cardiac Sinoatrial Node Cells

    Science.gov (United States)

    Pan, Zhenxing; Doi, Shinji

    As a cardiac pacemaker, sinoatrial node spontaneously generates periodic electrical signals (action potentials) in its cells. The action potential generation is deeply related to various ion channels in cell membranes, and the abnormalities of ion channels cause sinus arrhythmia. We use the Zhang model of sinoatrial node cells to investigate the relation between pacemaker rhythm (frequency of action potential generation) and ion channels. The Zhang model is described by the Hodgkin-Huxley-type nonlinear ordinary differential equations, and its parameter values vary between periphery and center cells of sinoatrial node. We analyze the bifurcation structure of the Zhang model, and investigate the variability of pacemaker rhythm and its sensitivity on ion channel conductance changes for both periphery and center cells. Moreover, these results are compared with the previous results of another sinoatrial node cell model: Yanagihara-Noma-Irisawa model.

  17. Ca2+-Clock-Dependent Pacemaking in the Sinus Node Is Impaired in Mice with a Cardiac Specific Reduction in SERCA2 Abundance

    Science.gov (United States)

    Logantha, Sunil Jit R. J.; Stokke, Mathis K.; Atkinson, Andrew J.; Kharche, Sanjay R.; Parveen, Sajida; Saeed, Yawer; Sjaastad, Ivar; Sejersted, Ole M.; Dobrzynski, Halina

    2016-01-01

    Background: The sarcoplasmic reticulum Ca2+-ATPase (SERCA2) pump is an important component of the Ca2+-clock pacemaker mechanism that provides robustness and flexibility to sinus node pacemaking. We have developed transgenic mice with reduced cardiac SERCA2 abundance (Serca2 KO) as a model for investigating SERCA2's role in sinus node pacemaking. Methods and Results: In Serca2 KO mice, ventricular SERCA2a protein content measured by Western blotting was 75% (P 70% reduction in SERCA2 activity. Conclusions: Serca2 KO mice show a disrupted Ca2+-clock-dependent pacemaker mechanism contributing to impaired sinus node and atrioventricular node function. PMID:27313537

  18. Multicellular automaticity of cardiac cell monolayers: effects of density and spatial distribution of pacemaker cells

    Science.gov (United States)

    Elber Duverger, James; Boudreau-Béland, Jonathan; Le, Minh Duc; Comtois, Philippe

    2014-11-01

    Self-organization of pacemaker (PM) activity of interconnected elements is important to the general theory of reaction-diffusion systems as well as for applications such as PM activity in cardiac tissue to initiate beating of the heart. Monolayer cultures of neonatal rat ventricular myocytes (NRVMs) are often used as experimental models in studies on cardiac electrophysiology. These monolayers exhibit automaticity (spontaneous activation) of their electrical activity. At low plated density, cells usually show a heterogeneous population consisting of PM and quiescent excitable cells (QECs). It is therefore highly probable that monolayers of NRVMs consist of a heterogeneous network of the two cell types. However, the effects of density and spatial distribution of the PM cells on spontaneous activity of monolayers remain unknown. Thus, a simple stochastic pattern formation algorithm was implemented to distribute PM and QECs in a binary-like 2D network. A FitzHugh-Nagumo excitable medium was used to simulate electrical spontaneous and propagating activity. Simulations showed a clear nonlinear dependency of spontaneous activity (occurrence and amplitude of spontaneous period) on the spatial patterns of PM cells. In most simulations, the first initiation sites were found to be located near the substrate boundaries. Comparison with experimental data obtained from cardiomyocyte monolayers shows important similarities in the position of initiation site activity. However, limitations in the model that do not reflect the complex beat-to-beat variation found in experiments indicate the need for a more realistic cardiomyocyte representation.

  19. Assessment of cardiac stroke volume in patients with implanted cardiac pacemaker using parametric electrical impedance tomography: a theoretical 2D study.

    Science.gov (United States)

    Mhajna, Muhammad; Abboud, Shimon

    2013-05-01

    The present theoretical study examines the ability to estimate cardiac stroke volume (CSV) in patients with implanted cardiac pacemaker using parametric electrical impedance tomography (pEIT) in a 2D computerized model of the thorax. CSV is a direct indicator of the cardiac pumping efficiency. The commonly used methods for measuring CSV require the invasive procedure of right heart catheterization or use expensive imaging techniques (i.e., MRI). Hence, experience with these techniques for diagnosis and monitoring has been limited to hospitalized patients. In the present study, pEIT scheme was applied in a computerized 2D model of the human thorax with implanted cardiac device to determine the left ventricular (LV) volume at different cardiac cycle phases. The LV was simulated as a prolate ellipse with its axes' lengths as the reconstruction parameters while all other geometries and conductivity values remained constant. An optimization was carried out in order to ensure that the ellipse is the appropriate model for the LV at each cardiac cycle phase. LV volumes calculated by both the pEIT algorithm and the ellipsoid model are consistent. A high correlation (ρ = 0.99) between the true and reconstructed volumes was found. The SV calculation error was ∼1%. The results suggest that the LV volume can be estimated using the pEIT method in a 2D computerized model, and that the method has the potential to be used for monitoring patients with implanted cardiac pacemaker.

  20. T-box transcription factor TBX3 reprogrammes mature cardiac myocytes into pacemaker-like cells.

    NARCIS (Netherlands)

    Bakker, M.L.; Boink, G.J.; Boukens, B.J.; Verkerk, A.O.; Boogaard, M.W. van den; Haan, A.D. den; Hoogaars, W.M.; Buermans, H.P.; Bakker, J.M. de; Seppen, J.; Tan, H.L.; Moorman, A.F.; Hoen, P.A.C. 't; Christoffels, V.M.

    2012-01-01

    AIM: Treatment of disorders of the sinus node or the atrioventricular node requires insights into the molecular mechanisms of development and homoeostasis of these pacemaker tissues. In the developing heart, transcription factor TBX3 is required for pacemaker and conduction system development. Here,

  1. One-year cardiac morphological and functional evolution following permanent pacemaker implantation in right ventricular septal position in chagasic patients

    Directory of Open Access Journals (Sweden)

    Otaviano da Silva Júnior

    2012-06-01

    Full Text Available INTRODUCTION: The septal position is an alternative site for cardiac pacing (CP that is potentially less harmful to cardiac function. METHODS: Patients with Chagas disease without heart failure submitted to permanent pacemaker (PP implantation at the Clinics Hospital of the Triângulo Mineiro Federal University (UFTM, were selected from February 2009 to February 2010. The parameters analyzed were ventricular remodeling, the degree of electromechanical dyssynchrony (DEM, exercise time and VO2 max during exercise testing (ET and functional class (NYHA. Echocardiography was performed 24 to 48h following implantation and after one year follow-up. The patients were submitted to ET one month postprocedure and at the end of one year. RESULTS: Thirty patients were included. Patient mean age was 59±13 years-old. Indication for PP implantation was complete atrioventricular (AV block in 22 (73.3% patients and 2nd degree AV block in the other eight (26.7%. All patients were in NYHA I and no changes occurred in the ET parameters. No variations were detected in echocardiographic remodeling measurements. Intraventricular dyssynchrony was observed in 46.6% of cases and interventricular dyssynchrony in 33.3% of patients after one year. CONCLUSIONS: The findings of this work suggest that there is not significant morphological and functional cardiac change following pacemaker implantation in septal position in chagasic patients with normal left ventricular function after one year follow-up. Thus, patients may remain asymptomatic, presenting maintenance of functional capacity and no left ventricular remodeling.

  2. Medicare’s Policies and Prospective Payment Rates for Cardiac Pacemaker Surgeries need Review and Revision.

    Science.gov (United States)

    1985-02-26

    pacemaker manufacturers whose sales account for about 80 percent of the pacemaker sales in the United States. The four manufacturers are: -- Cordis ...percentage increase in the hospital market basket (an index designed to measure changes in the prices hospitals pay for goods and services) plus 0.25 percent...For fiscal year 1986, the DRG payment rates cannot be in- creased by more than the estimated change in the hospital market basket plus 0.25 percent

  3. What Is a Pacemaker?

    Science.gov (United States)

    ... it work? •A pacemaker uses batteries to send electric signals to your heart to help it pump the right way. • The pacemaker is connected to your heart by one or more wires. Tiny electric charges that you can’t feel move through ...

  4. Mechanisms of Beat-to-Beat Regulation of Cardiac Pacemaker Cell Function by Ca2+ Cycling Dynamics

    Science.gov (United States)

    Yaniv, Yael; Stern, Michael D.; Lakatta, Edward G.; Maltsev, Victor A.

    2013-01-01

    Whether intracellular Ca2+ cycling dynamics regulate cardiac pacemaker cell function on a beat-to-beat basis remains unknown. Here we show that under physiological conditions, application of low concentrations of caffeine (2–4 mM) to isolated single rabbit sinoatrial node cells acutely reduces their spontaneous action potential cycle length (CL) and increases Ca2+ transient amplitude for several cycles. Numerical simulations, using a modified Maltsev-Lakatta coupled-clock model, faithfully reproduced these effects, and also the effects of CL prolongation and dysrhythmic spontaneous beating (produced by cytosolic Ca2+ buffering) and an acute CL reduction (produced by flash-induced Ca2+ release from a caged Ca2+ buffer), which we had reported previously. Three contemporary numerical models (including the original Maltsev-Lakatta model) failed to reproduce the experimental results. In our proposed new model, Ca2+ releases acutely change the CL via activation of the Na+/Ca2+ exchanger current. Time-dependent CL reductions after flash-induced Ca2+ releases (the memory effect) are linked to changes in Ca2+ available for pumping into sarcoplasmic reticulum which, in turn, changes the sarcoplasmic reticulum Ca2+ load, diastolic Ca2+ releases, and Na+/Ca2+ exchanger current. These results support the idea that Ca2+ regulates CL in cardiac pacemaker cells on a beat-to-beat basis, and suggest a more realistic numerical mechanism of this regulation. PMID:24094396

  5. Mechanisms of beat-to-beat regulation of cardiac pacemaker cell function by Ca²⁺ cycling dynamics.

    Science.gov (United States)

    Yaniv, Yael; Stern, Michael D; Lakatta, Edward G; Maltsev, Victor A

    2013-10-01

    Whether intracellular Ca(2+) cycling dynamics regulate cardiac pacemaker cell function on a beat-to-beat basis remains unknown. Here we show that under physiological conditions, application of low concentrations of caffeine (2-4 mM) to isolated single rabbit sinoatrial node cells acutely reduces their spontaneous action potential cycle length (CL) and increases Ca(2+) transient amplitude for several cycles. Numerical simulations, using a modified Maltsev-Lakatta coupled-clock model, faithfully reproduced these effects, and also the effects of CL prolongation and dysrhythmic spontaneous beating (produced by cytosolic Ca(2+) buffering) and an acute CL reduction (produced by flash-induced Ca(2+) release from a caged Ca(2+) buffer), which we had reported previously. Three contemporary numerical models (including the original Maltsev-Lakatta model) failed to reproduce the experimental results. In our proposed new model, Ca(2+) releases acutely change the CL via activation of the Na(+)/Ca(2+) exchanger current. Time-dependent CL reductions after flash-induced Ca(2+) releases (the memory effect) are linked to changes in Ca(2+) available for pumping into sarcoplasmic reticulum which, in turn, changes the sarcoplasmic reticulum Ca(2+) load, diastolic Ca(2+) releases, and Na(+)/Ca(2+) exchanger current. These results support the idea that Ca(2+) regulates CL in cardiac pacemaker cells on a beat-to-beat basis, and suggest a more realistic numerical mechanism of this regulation.

  6. SU-E-T-802: Verification of Implanted Cardiac Pacemaker Doses in Intensity-Modulated Radiation Therapy: Dose Prediction Accuracy and Reduction Effect of a Lead Sheet

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J [Dept. of Radiation Oncology, Konkuk University Medical Center, Seoul (Korea, Republic of); Chung, J [Dept. of Radiation Oncology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2015-06-15

    Purpose: To verify delivered doses on the implanted cardiac pacemaker, predicted doses with and without dose reduction method were verified using the MOSFET detectors in terms of beam delivery and dose calculation techniques in intensity-modulated radiation therapy (IMRT). Methods: The pacemaker doses for a patient with a tongue cancer were predicted according to the beam delivery methods [step-and-shoot (SS) and sliding window (SW)], intensity levels for dose optimization, and dose calculation algorithms. Dosimetric effects on the pacemaker were calculated three dose engines: pencil-beam convolution (PBC), analytical anisotropic algorithm (AAA), and Acuros-XB. A lead shield of 2 mm thickness was designed for minimizing irradiated doses to the pacemaker. Dose variations affected by the heterogeneous material properties of the pacemaker and effectiveness of the lead shield were predicted by the Acuros-XB. Dose prediction accuracy and the feasibility of the dose reduction strategy were verified based on the measured skin doses right above the pacemaker using mosfet detectors during the radiation treatment. Results: The Acuros-XB showed underestimated skin doses and overestimated doses by the lead-shield effect, even though the lower dose disagreement was observed. It led to improved dose prediction with higher intensity level of dose optimization in IMRT. The dedicated tertiary lead sheet effectively achieved reduction of pacemaker dose up to 60%. Conclusion: The current SS technique could deliver lower scattered doses than recommendation criteria, however, use of the lead sheet contributed to reduce scattered doses.Thin lead plate can be a useful tertiary shielder and it could not acuse malfunction or electrical damage of the implanted pacemaker in IMRT. It is required to estimate more accurate scattered doses of the patient with medical device to design proper dose reduction strategy.

  7. Pacemaker Created in Human Ventricle by Depressing Inward-Rectifier K+ Current: A Simulation Study

    Science.gov (United States)

    Zhang, Yue; Li, Qince; Zhang, Henggui

    2016-01-01

    Cardiac conduction disorders are common diseases which cause slow heart rate and syncope. The best way to treat these diseases by now is to implant electronic pacemakers, which, yet, have many disadvantages, such as the limited battery life and infection. Biopacemaker has been expected to replace the electronic devices. Automatic ventricular myocytes (VMs) could show pacemaker activity, which was induced by depressing inward-rectifier K+ current (IK1). In this study, a 2D model of human biopacemaker was created from the ventricular endocardial myocytes. We examined the stability of the created biopacemaker and investigated its driving capability by finding the suitable size and spatial distribution of the pacemaker for robust pacing and driving the surrounding quiescent cardiomyocytes. Our results suggest that the rhythm of the pacemaker is similar to that of the single cell at final stable state. The driving force of the biopacemaker is closely related to the pattern of spatial distribution of the pacemaker. PMID:26998484

  8. Pacemaker Created in Human Ventricle by Depressing Inward-Rectifier K+ Current: A Simulation Study

    Directory of Open Access Journals (Sweden)

    Yue Zhang

    2016-01-01

    Full Text Available Cardiac conduction disorders are common diseases which cause slow heart rate and syncope. The best way to treat these diseases by now is to implant electronic pacemakers, which, yet, have many disadvantages, such as the limited battery life and infection. Biopacemaker has been expected to replace the electronic devices. Automatic ventricular myocytes (VMs could show pacemaker activity, which was induced by depressing inward-rectifier K+ current (IK1. In this study, a 2D model of human biopacemaker was created from the ventricular endocardial myocytes. We examined the stability of the created biopacemaker and investigated its driving capability by finding the suitable size and spatial distribution of the pacemaker for robust pacing and driving the surrounding quiescent cardiomyocytes. Our results suggest that the rhythm of the pacemaker is similar to that of the single cell at final stable state. The driving force of the biopacemaker is closely related to the pattern of spatial distribution of the pacemaker.

  9. [Rehabilitation of patients with cardiac pacemakers and implanted cardioverter-defibrillators: recommendations for training, physiotherapeutic procedures and re-employment].

    Science.gov (United States)

    Reibis, R K; Kamke, W; Langheim, E; Völler, H

    2010-04-01

    Rehabilitation of patients with cardiac pacemakers (CP) or implantable cardioverter defibrillators (ICD) comprises secondary prevention of underlying cardiac disease, conditioning training activities and psychological education and includes furthermore the assessment of aggregate function, detection of any device malfunction as well as the return to work efforts. The extent to which the physical activities can be permitted is determined by both cardiopulmonary capacity and the primary arrhythmic indication. Under consideration of upper frequency limit, left ventricular dysfunction and the avoidance of mechanical exposure on device can and leads, an individually designed training programme is acceptable even on a high load level. Likewise, electrotherapeutic procedures due to musculoskeletal pain syndrome are not generally contraindicated, if differentiated limitations are respected. Beside the assessment of aggregate function and, if necessary, parameter optimization, psychologic intervention programs play an important role particularly in ICD-patients and can be utilized as an additive therapeutic module. Personalized recommendations for driving with an ICD are determined by the time interval since idex arrhythmia and the rhythmological risk profile as well as by the motor vehicle class. The return to work rate of CP and ICD patients is resumably influenced by the underlying cardiac disease and to a lesser extend by the implanted device. Except industrial jobs the risk of electromagnetic interference during the working process is low and can be objected by working place analysis including noise field measurement. Thus cardiac of CP and ICD patients should be used to a large extend for the recovery of individual physical and psychological integrity as well as for the organisation of reemployment.

  10. Coil embolization of internal mammary artery injured during central vein catheter and cardiac pacemaker lead insertion

    Energy Technology Data Exchange (ETDEWEB)

    Chemelli, A.P. [Department of Radiology, Innsbruck Medical University, Anichstrasse 35, 6020 Innsbruck (Austria)], E-mail: Andreas.Chemelli@i-med.ac.at; Chemelli-Steingruber, I.E. [Department of Radiology, Innsbruck Medical University, Anichstrasse 35, 6020 Innsbruck (Austria); Bonaros, N. [Department of Cardiovascular Surgery, Innsbruck Medical University (Austria); Luckner, G. [Department of Anaesthesiology and Critical Care Medicine, Innsbruck Medical University (Austria); Millonig, G. [Department of Gastroenterology and Hepatology, Innsbruck Medical University (Austria); Seppi, K. [Department of Neurology, Innsbruck Medical University (Austria); Lottersberger, C.; Jaschke, W. [Department of Radiology, Innsbruck Medical University, Anichstrasse 35, 6020 Innsbruck (Austria)

    2009-08-15

    Purpose: This study describes several cases of endovascular coil embolization of the proximal internal mammary artery injured by blind approach to the subclavian vein for central venous catheter or pacemaker lead insertion. Materials and methods: We conducted a retrospective analysis of five patients with iatrogenic arterial lesions of the internal mammary artery (IMA). The lesions occurred in three patients from a puncture of the subclavian vein during insertion of a central venous catheter and in two patients from a puncture of the subclavian vein for insertion of a pacemaker lead. Four patients had acute symptoms of bleeding with mediastinal hematoma and hematothorax and one patient was investigated in a chronic stage. A pseudoaneurysm was detected in all five patients. All four acute and hemodynamic unstable patients required hemodynamic support. Results: In all patients, embolization was performed using a coaxial catheter technique, and a long segment of the IMA adjacent distally and proximally to the source of bleeding was occluded with pushable microcoils. In one patient, additional mechanically detachable microcoils were used at the very proximal part of the IMA. Microcoil embolization of the IMA was successful in all patients, and the source of bleeding was eliminated in all patients. Conclusion: Transarterial coil embolization is a feasible and efficient method in treating acute bleeding and pseudoaneurysm of the IMA and should be considered if mediastinal hematoma or hemathorax occurs after blind puncture of the subclavian vein.

  11. Safety Profile of Liver FibroScan in Patients with Cardiac Pacemakers or Implantable Cardioverter-Defibrillators

    Science.gov (United States)

    Pranke, Stephanie; Rashidi, Farid; Nosib, Shravan; Worobetz, Lawrence

    2017-01-01

    Background. Emerging evidence suggests that nonalcoholic fatty liver disease (NAFLD) is associated with coronary artery diseases and arrhythmias. The FibroScan (Echosens, France), a widely available, noninvasive device, is able to detect liver fibrosis and steatosis within this patient population. However, the FibroScan is currently contraindicated in patients with cardiac pacemakers (PM) or implantable cardioverter-defibrillators (ICD). Objective. To determine the safety profile of FibroScan testing in patients with PM or ICD. Methods. Consecutive outpatients undergoing routine device interrogations at a tertiary level teaching hospital underwent simultaneous liver stiffness measurements. PM or ICD performance data, device types, patient demographics, medical history, and previous laboratory and conventional liver imaging results were collected. Results. Analysis of 107 subjects with 33 different types of implanted cardiac devices, from 5 different companies (Medtronic, Sorin, ELA Medical, Boston Scientific, and St. Jude), did not demonstrate any adverse events as defined by abnormal device sensing/pacing or ICD firing. This population included high risk subjects undergoing active pacing (n = 53) and with right pectoral PM placement (n = 1). None of the subjects had any clinical signs of decompensated congestive heart failure or cirrhosis during the exam. Conclusion. TE with FibroScan can be safely performed in patients with PM or ICD.

  12. The missing link in the mystery of normal automaticity of cardiac pacemaker cells.

    Science.gov (United States)

    Lakatta, Edward G; Vinogradova, Tatiana M; Maltsev, Victor A

    2008-03-01

    Earlier studies of the initiating event of normal automaticity of the heart's pacemaker cells, inspired by classical quantitative membrane theory, focused upon ion currents (IK, I f) that determine the maximum diastolic potential and the early phase of the spontaneous diastolic depolarization (DD). These early DD events are caused by the prior action potential (AP) and essentially reflect a membrane recovery process. Events following the recovery process that ignite APs have not been recognized and remained a mystery until recently. These critical events are linked to rhythmic intracellular signals initiated by Ca2+ clock (i.e., sarcoplasmic reticulum [SR] cycling Ca2+). Sinoatrial cells, regardless of size, exhibit intense ryanodine receptor (RyR), Na+/Ca2+ exchange (NCX)-1, and SR Ca2+ ATPase-2 immunolabeling and dense submembrane NCX/RyR colocalization; Ca2+ clocks generate spontaneous stochastic but roughly periodic local subsarcolemmal Ca2+ releases (LCR). LCRs generate inward currents via NCX that exponentially accelerate the late DD. The timing and amplitude of LCR/I NCX-coupled events control the timing and amplitude of the nonlinear terminal DD and therefore ultimately control the chronotropic state by determining the timing of the I CaL activation that initiates the next AP. LCR period is precisely controlled by the kinetics of SR Ca2+ cycling, which, in turn, are regulated by 1) the status of protein kinase A-dependent phosphorylation of SR Ca2+ cycling proteins; and 2) membrane ion channels ensuring the Ca2+ homeostasis and therefore the Ca2+ available to Ca2+ clock. Thus, the link between early DD and next AP, missed in earlier studies, is ensured by a precisely physiologically regulated Ca2+ clock within pacemaker cells that integrates multiple Ca2+-dependent functions and rhythmically ignites APs during late DD via LCRs-I NCX coupling.

  13. Pacemaker current inhibition in experimental human cardiac sympathetic activation: a double-blind, randomized, crossover study

    NARCIS (Netherlands)

    Schroeder, C.; Heusser, K.; Zoerner, A.A.; Grosshennig, A.; Wenzel, D.; May, M.; Sweep, F.C.; Mehling, H.; Luft, F.C.; Tank, J.; Jordan, J.

    2014-01-01

    Hyperpolarization-activated, cyclic nucleotide-gated 4 (HCN4) channels comprise the final pathway for autonomic heart rate (HR) regulation. We hypothesized that HCN4 inhibition could reverse autonomic imbalance in a human model of cardiac sympathetic activation. Nineteen healthy men ingested oral me

  14. Cardiac resynchronization therapy pacemaker: critical appraisal of the adaptive CRT-P device

    Directory of Open Access Journals (Sweden)

    Daoud GE

    2016-01-01

    Full Text Available Georges E Daoud,1 Mahmoud Houmsse2 1Department of the Biomedical Research, 2Division of Cardiovascular Medicine, The Ohio State University Wexner Medical Center, Columbus, OH, USA Abstract: Cardiac resynchronization therapy (CRT is an effective and well-established therapy for patients suffering with heart failure, left ventricular (LV systolic dysfunction (ejection fraction ≤35%, and electrical dyssynchrony, demonstrated by a surface QRS duration of ≥120 ms. Patients undergoing treatment with CRT have shown significant improvement in functional class, quality of life, LV ejection fraction, exercise capacity, hemodynamics, and reverse remodeling of LV, and ultimately, morbidity and mortality. However, 30%–40% of patients who receive a CRT device may not show improvement, and they are termed as nonresponders. The nonresponders have a poor prognosis; several methods have been developed to try to enhance response to CRT. Echocardiography-guided optimization of CRT has not resulted in significant clinical benefit, since it is done at rest with the patient in supine position. An ideal optimization strategy would provide continuous monitoring and adjustment of device pacing to provide maximal cardiac resynchronization, under a multitude of physiologic states. Intrinsic activation of the right ventricle (RV with paced activation of the RV, even in the setting of biventricular (BiV pacing, may result in an adverse effect on cardiac performance. With this physiology, the use of LV-only pacing may be preferred and may enhance CRT. Adaptive CRT is a novel device-based algorithm that was designed to achieve patient-specific adjustment in CRT so as to provide appropriate BiV pacing or LV-only pacing. This article will review the goals of CRT optimization, and implementation and outcomes associated with adaptive CRT. Keywords: heart failure, cardiac resynchronization, therapy, adaptive, left and biventricular pacing

  15. Cardiac electronic pacemakers and biological Pacemakers%心脏电子起搏器时代与生物起搏替代的前沿话题

    Institute of Scientific and Technical Information of China (English)

    周亚峰; 杨向军

    2008-01-01

    植入电子起搏器是目前治疗症状性缓慢心律失常的主要方法,然而它存在许多缺点.能否利用分子生物学原理发展生物起搏器成为大家关注的热点.通过转染编码If电流的超极化激活环核苷酸门控通道基因,过度表达超极化激活环核苷酸门控通道,增加心脏舒张期内向电流,从而在窦房结被抑制时提供起搏作用,这种利用基因治疗和细胞治疗构建的生物起搏在不久的将来可能会成为电子起搏器最为理想的替代方法.目的:总结超极化激活环核苷酸门控通道基因构建生物起搏的研究进展.检索策略:由该论文的研究人员应用计算机检索.Pubmed数据库1979-01/2007-06的相关文献.检索词"hyperpolarization-activated cyclic nucleotide-gated nnel;biological pacemaker",并限定文章语言种类为English.共检索到157篇文献,对资料进行初审,纳入标准:①与生物起搏及超极化激活环核苷酸门控通道基因密切相关.②同一领域选择近期发表或在权威杂志上发表的文章.排除标准:重复性研究.文献评价:文献的来源主要是超极化激活环核苷酸门控通道基因的基础实验.所选剧的36篇文献中,10篇为综述,其余均为临床或基础实验研究.资料综合:①在4种异构体中超极化激活环核苷酸门控通道1,2,4是心脏中的主要部分,超极化激活环核苷酸门控通道3只在胚胎起搏细胞中有低水平表达.起搏活性小的区域(如心室肌),超极化激活环核苷酸门控通道2的表达占优势;而起搏活性高的区域超极化激活环核苷酸门控通道4的表达占优势.此外,超极化激活环核苷酸门控通道2在整个发育阶段,是心室的主要异构体,超极化激活环核苷酸门控通道2:超极化激活环核苷酸门控通道4的相当表达量在乳鼠为5:1,成年鼠为13:1.②超极化激活环核苷酸门控通道通道缺陷可导致病窦综合征.③到目前为止.转染编码If

  16. Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

    Energy Technology Data Exchange (ETDEWEB)

    Ghafarian, Pardis [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Aghamiri, S.M.R. [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Ay, Mohammad R. [Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Research Institute for Nuclear Medicine, Tehran (Iran, Islamic Republic of); Rahmim, Arman [Johns Hopkins University, Department of Radiology, Baltimore, MD (United States); Schindler, Thomas H. [Geneva University, Cardiovascular Center, Nuclear Cardiology, Geneva (Switzerland); Ratib, Osman [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Geneva University, Geneva Neuroscience Center, Geneva (Switzerland)

    2011-02-15

    Cardiac PET/CT imaging is often performed in patients with pacemakers and implantable cardioverter defibrillator (ICD) leads. However, metallic implants usually produce artefacts on CT images which might propagate to CT-based attenuation-corrected (CTAC) PET images. The impact of metal artefact reduction (MAR) for CTAC of cardiac PET/CT images in the presence of pacemaker, ICD and ECG leads was investigated using both qualitative and quantitative analysis in phantom and clinical studies. The study included 14 patients with various leads undergoing perfusion and viability examinations using dedicated cardiac PET/CT protocols. The PET data were corrected for attenuation using both artefactual CT images and CT images corrected using the MAR algorithm. The severity and magnitude of metallic artefacts arising from these leads were assessed on both linear attenuation coefficient maps ({mu}-maps) and attenuation-corrected PET images. CT and PET emission data were obtained using an anthropomorphic thorax phantom and a dedicated heart phantom made in-house incorporating pacemaker and ICD leads attached at the right ventricle of the heart. Volume of interest-based analysis and regression plots were performed for regions related to the lead locations. Bull's eye view analysis was also performed on PET images corrected for attenuation with and without the MAR algorithm. In clinical studies, the visual assessment of PET images by experienced physicians and quantitative analysis did not reveal erroneous interpretation of the tracer distribution or significant differences when PET images were corrected for attenuation with and without MAR. In phantom studies, the mean differences between tracer uptake obtained without and with MAR were 10.16{+-}2.1% and 6.86{+-}2.1% in the segments of the heart in the vicinity of metallic ICD or pacemaker leads, and were 4.43{+-}0.5% and 2.98{+-}0.5% in segments far from the leads. Although the MAR algorithm was able to effectively improve

  17. Numerical models based on a minimal set of sarcolemmal electrogenic proteins and an intracellular Ca(2+) clock generate robust, flexible, and energy-efficient cardiac pacemaking.

    Science.gov (United States)

    Maltsev, Victor A; Lakatta, Edward G

    2013-06-01

    Recent evidence supports the idea that robust and, importantly, FLEXIBLE automaticity of cardiac pacemaker cells is conferred by a coupled system of membrane ion currents (an "M-clock") and a sarcoplasmic reticulum (SR)-based Ca(2+) oscillator ("Ca(2+)clock") that generates spontaneous diastolic Ca(2+) releases. This study identified numerical models of a human biological pacemaker that features robust and flexible automaticity generated by a minimal set of electrogenic proteins and a Ca(2+)clock. Following the Occam's razor principle (principle of parsimony), M-clock components of unknown molecular origin were excluded from Maltsev-Lakatta pacemaker cell model and thirteen different model types of only 4 or 5 components were derived and explored by a parametric sensitivity analysis. The extended ranges of SR Ca(2+) pumping (i.e. Ca(2+)clock performance) and conductance of ion currents were sampled, yielding a large variety of parameter combination, i.e. specific model sets. We tested each set's ability to simulate autonomic modulation of human heart rate (minimum rate of 50 to 70bpm; maximum rate of 140 to 210bpm) in response to stimulation of cholinergic and β-adrenergic receptors. We found that only those models that include a Ca(2+)clock (including the minimal 4-parameter model "ICaL+IKr+INCX+Ca(2+)clock") were able to reproduce the full range of autonomic modulation. Inclusion of If or ICaT decreased the flexibility, but increased the robustness of the models (a relatively larger number of sets did not fail during testing). The new models comprised of components with clear molecular identity (i.e. lacking IbNa & Ist) portray a more realistic pacemaking: A smaller Na(+) influx is expected to demand less energy for Na(+) extrusion. The new large database of the reduced coupled-clock numerical models may serve as a useful tool for the design of biological pacemakers. It will also provide a conceptual basis for a general theory of robust, flexible, and energy

  18. Numerical models based on a minimal set of sarcolemmal electrogenic proteins and an intracellular Ca2+ clock generate robust, flexible, and energy-efficient cardiac pacemaking

    Science.gov (United States)

    Maltsev, Victor A.; Lakatta, Edward G.

    2015-01-01

    Recent evidence supports the idea that robust and, importantly, FLEXIBLE automaticity of cardiac pacemaker cells is conferred by a coupled system of membrane ion currents (an “M-clock”) and a sarcoplasmic reticulum (SR)-based Ca2+ oscillator (“Ca2+clock”) that generates spontaneous diastolic Ca2+ releases. This study identified numerical models of a human biological pacemaker that features robust and flexible automaticity generated by a minimal set of electrogenic proteins and a Ca2+clock. Following the Occam’s razor principle (principle of parsimony), M-clock components of unknown molecular origin were excluded from Maltsev-Lakatta pacemaker cell model and thirteen different model types of only 4 or 5 components were derived and explored by a parametric sensitivity analysis. The extended ranges of SR Ca2+ pumping (i.e. Ca2+clock performance) and conductance of ion currents were sampled, yielding a large variety of parameter combination, i.e. specific model sets. We tested each set’s ability to simulate autonomic modulation of human heart rate (minimum rate of 50 to 70 bpm; maximum rate of 140 to 210 bpm) in response to stimulation of cholinergic and β-adrenergic receptors. We found that only those models that include a Ca2+clock (including the minimal 4-parameter model “ICaL+IKr+INCX+Ca2+clock”) were able to reproduce the full range of autonomic modulation. Inclusion of If or ICaT decreased the flexibility, but increased the robustness of the models (a relatively larger number of sets did not fail during testing). The new models comprised of components with clear molecular identity (i.e. lacking IbNa & Ist) portray a more realistic pacemaking: A smaller Na+ influx is expected to demand less energy for Na+ extrusion. The new large database of the reduced coupled-clock numerical models may serve as a useful tool for the design of biological pacemakers. It will also provide a conceptual basis for a general theory of robust, flexible, and energy

  19. Crosstalk between mitochondrial and sarcoplasmic reticulum Ca2+ cycling modulates cardiac pacemaker cell automaticity.

    Directory of Open Access Journals (Sweden)

    Yael Yaniv

    Full Text Available BACKGROUND: Mitochondria dynamically buffer cytosolic Ca(2+ in cardiac ventricular cells and this affects the Ca(2+ load of the sarcoplasmic reticulum (SR. In sinoatrial-node cells (SANC the SR generates periodic local, subsarcolemmal Ca(2+ releases (LCRs that depend upon the SR load and are involved in SANC automaticity: LCRs activate an inward Na(+-Ca(2+ exchange current to accelerate the diastolic depolarization, prompting the ensemble of surface membrane ion channels to generate the next action potential (AP. OBJECTIVE: To determine if mitochondrial Ca(2+ (Ca(2+ (m, cytosolic Ca(2+ (Ca(2+ (c-SR-Ca(2+ crosstalk occurs in single rabbit SANC, and how this may relate to SANC normal automaticity. RESULTS: Inhibition of mitochondrial Ca(2+ influx into (Ru360 or Ca(2+ efflux from (CGP-37157 decreased [Ca(2+](m to 80 ± 8% control or increased [Ca(2+](m to 119 ± 7% control, respectively. Concurrent with inhibition of mitochondrial Ca(2+ influx or efflux, the SR Ca(2+ load, and LCR size, duration, amplitude and period (imaged via confocal linescan significantly increased or decreased, respectively. Changes in total ensemble LCR Ca(2+ signal were highly correlated with the change in the SR Ca(2+ load (r(2 = 0.97. Changes in the spontaneous AP cycle length (Ru360, 111 ± 1% control; CGP-37157, 89 ± 2% control in response to changes in [Ca(2+](m were predicted by concurrent changes in LCR period (r(2 = 0.84. CONCLUSION: A change in SANC Ca(2+ (m flux translates into a change in the AP firing rate by effecting changes in Ca(2+ (c and SR Ca(2+ loading, which affects the characteristics of spontaneous SR Ca(2+ release.

  20. Recent Progression in the clinical application of Permanent cardiac pacemakers%心脏永久性起搏器临床应用的新进展

    Institute of Scientific and Technical Information of China (English)

    吴笛; 刘全

    2007-01-01

    OBJECTIVE:TO summarize the newest clinical application of permanent cardiac pacemaker, and introduce the relationship between the therapy efficacy and mechanism.DATA SOURCES: Related papers were searched in Pubmed from January 2000 to December 2006 with the terms of "pacemaker,application",and the language of paper was limited to English,at the same time,related papers were searched in WangFang Database with the same terms and the language of paper was limited to Chinese.STUDY SELECTION:The papers relevant to the newest large-scale clinical trial about the cardiac pacemaker were primarily collected.Exclusion criteria:repetitive studies.DATA EXTRACTION:A total of 203 pieces of papers related to the newest clinical application of cardiac pacemaker were collected,among which,30 pieces accorded with the inclusion criteria.DATA SYNTHESIS:The pacemaker can simulate the normal myocardium cell's function pacing and conducting the rhythm. Consequently it can substitute the abnormal myocardium cell to ensure the sequence and completeness of the cardiac pacing and conducting system,the natural electrophysiological activity,and the efficiency of the cardiac ejection and blood supply.The clinical application is not only for single bradycardia, but also for cardiac electric failure, cardiac electric turbulence,and some heart diseases without cardiac electric abnormity.With pacemaker miniaturization,digital signal processing, improved diagnostics and endocardial electrograms, modern pacemakers are able to offer a sophisticated therapeutic and diagnostic platform for the patients with refractory symptoms.CONCLUSION:The pacemaker can simulate the normal myocardium cell's function pacing and conducting the rhythm.It therapy for congenital heart disease.%目的:慨述心脏永久性起搏器的最新临床应用,介绍其治疗效果与机械制造机制的关系.资料来源:检索Pubmed 2000-01/2006-12与心脏永久性起搏器临床应用相关的文献,检索词为"pacemaker

  1. Force and torque effects of a 1.5-Tesla MRI scanner on cardiac pacemakers and ICDs.

    Science.gov (United States)

    Luechinger, R; Duru, F; Scheidegger, M B; Boesiger, P; Candinas, R

    2001-02-01

    Magnetic resonance imaging (MRI) is a widely accepted tool for the diagnosis of a variety of disease states. However, the presence of an implanted pacemaker is considered to be a strict contraindication to MRI in a vast majority of centers due to safety concerns. In phantom studies, the authors investigated the force and torque effects of the static magnetic field of MRI on pacemakers and ICDs. Thirty-one pacemakers (15 dual chamber and 16 single chamber units) from eight manufacturers and 13 ICDs from four manufacturers were exposed to the static magnetic field of a 1.5-Tesla MRI scanner. Magnetic force and acceleration measurements were obtained quantitatively, and torque measurements were made qualitatively. For pacemakers, the measured magnetic force was in the range of 0.05-3.60 N. Pacemakers released after 1995 had low magnetic force values as compared to the older devices. For these devices, the measured acceleration was even lower than the gravity of the earth (static magnetic field of a 1.5-Tesla MRI scanner. However, ICD devices, despite considerable reduction in size and weight, may still pose problems due to strong magnetic force and torque.

  2. Role of sinoatrial node architecture in maintaining a balanced source-sink relationship and synchronous cardiac pacemaking

    Directory of Open Access Journals (Sweden)

    Sathya D Unudurthi

    2014-11-01

    Full Text Available Normal heart rhythm (sinus rhythm depends on regular activity of the sinoatrial node (SAN, a heterogeneous collection of specialized myocytes in the right atrium. SAN cells, in general, possess a unique electrophysiological profile that promotes spontaneous electrical activity (automaticity. However, while automaticity is required for normal pacemaking, it is not necessarily sufficient. Less appreciated is the importance of the elaborate structure of the SAN complex for proper pacemaker function. Here, we review the important structural features of the SAN with a focus on how these elements help manage a precarious balance between electrical charge generated by the SAN (source and the charge needed to excite the surrounding atrial tissue (sink. We also discuss how compromised source-sink balance due, for example to fibrosis, may promote SAN dysfunction, characterized by slow and/or asynchronous pacemaker activity and even failure, in the setting of cardiovascular disease (e.g. heart failure, atrial fibrillation. Finally, we discuss implications of the source-sink balance in the SAN complex for cell and gene therapies aimed at creating a biological pacemaker as replacement or bridge to conventional electronic pacemakers.

  3. Dynamic interactions of an intracellular Ca2+ clock and membrane ion channel clock underlie robust initiation and regulation of cardiac pacemaker function.

    Science.gov (United States)

    Maltsev, Victor A; Lakatta, Edward G

    2008-01-15

    For almost half a century it has been thought that the initiation of each heartbeat is driven by surface membrane voltage-gated ion channels (M clocks) within sinoatrial nodal cells. It has also been assumed that pacemaker cell automaticity is initiated at the maximum diastolic potential (MDP). Recent experimental evidence based on confocal cell imaging and supported by numerical modelling, however, shows that initiation of cardiac impulse is a more complex phenomenon and involves yet another clock that resides under the sarcolemma. This clock is the sarcoplasmic reticulum (SR): it generates spontaneous, but precisely timed, rhythmic, submembrane, local Ca(2+) releases (LCR) that appear not at the MDP but during the late, diastolic depolarization (DD). The Ca(2+) clock and M clock dynamically interact, defining a novel paradigm of robust cardiac pacemaker function and regulation. Rhythmic LCRs during the late DD activate inward Na(+)/Ca(2+) exchanger currents and ignite action potentials, which in turn induceCa(2+) transients and SR depletions, resetting the Ca(2+) clock. Both basal and reserve protein kinaseA-dependent phosphorylation of Ca(2+) cycling proteins control the speed and amplitude of SR Ca(2+) cycling to regulate the beating rate by strongly coupled Ca(2+) and M clocks.

  4. Lithium batteries. (Latest citations from the EI Compendex*plus database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-02-01

    The bibliography contains citations concerning the design, development, and applications of lithium batteries. Topics include electrochemical aspects, cycling characteristics, performance evaluations, and applications in cardiac pacemaker devices. Batteries using organic compounds, chlorides, and metal sulfides are discussed. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  5. [Current developments on the physiology of the cardiac atrial pacemaker an excitation conduction of the left atrium].

    Science.gov (United States)

    Arrigo, L; Avanzino, G L

    1979-06-30

    According to recent developments the atrial pacemaker area and the right atrium show a peculiar morpho-functional organization, i.e.: 1) The pacemaker area is formed of clusters of cells containing relatively few myofibrils and showing embryologic characteristics. Such cells are known as nodal cells and between these and the atrial muscles are in general situated transitional cells. Each cluster is separated from the other by collagenous boundaries. The resistance of the membranes to the current flow seems to be relatively low between the cells of the same cluster but the collagenous boundaries are, according to TRAUTWEIN e UCHIZONO (1963), very poor conductors. The pacemaker activity seems to originate inside the various clusters. 2) The functional relationships between the sinoatrial node and the atrioventricular node as well as the interatrial relationship would take place through preferential pathways. These pathways corresponding approximately to the tracts described by JAMES (1966) (anterior, posterior and middle internodal tracts) and to the interatrial or Bachmann bundle, seems to show a higher velocity conduction. In general the fibres of which the tracts are composed are neither morphologically nor functionally isolated from the atrial muscle. The functional consequences of the above mentioned nodal and atrial organization seems to be: a) The possible conditioning of the pacemaker functions by the various clusters activity i.e. the dominance of one cluster over another. b) The shifting of the pacemaker activity from one cluster to anothr due to the arrival of nervous stimuli or chemical substances, etc. According to some Authors as a consequence of the shift the pacemaker area can sometimes move out side the nodal tissue and settle inside an area belonging to the internodal pathways. c) Another consequence of the shift can be the different involvement of the conducting pathways which can lead to a change in the dynamics of the atrial invasion by the

  6. 非心脏手术围手术期临时心脏起搏器应用体会%The Application Experience of Temporary Cardiac Pacemaker on the Perioperative Period in Patients Undergoing Noncardiac Operations

    Institute of Scientific and Technical Information of China (English)

    朱正芳; 张伟国; 姚丽琴; 陈泽

    2014-01-01

    Objective To discussion the protection of temporary cardiac pacemaker on perioperative period in midadged bradyarrhythmias patients .methods Temporary cardiac pacemaker was placed in 22 cases noncardiac operations with bradyarrhythmias before operation ,the working condition of cardiac pacemaker and heart rate、cardiac rhythm and blood pressure were observed .Results 16 cases were finished in condition of pacemaker working ,and pacemake have been still working on 10 cases after operation ,untill signs were stable ;1 pacemaker dependent patient received treatment of permanent cardiac pacemaker .6 cases keeps standby status .The perioperative period was passed safely in all cases .Conclusion It is necessary that temporary cardiac pacemaker placed on perioperative peri-od of noncardiac operations with bradyarrhythmias ,and improves the security of the patients undergoing noncardiac operations .%目的:探讨临时心脏起搏器在中老年缓慢心律失常患者围手术期的保护作用。方法:对22例合并缓慢心律失常的非心脏手术患者在手术前予临时心脏起搏器安装术,了解心脏起搏器在围手术期工作情况,并密切观察患者的心率、心律、血压等生命体征变化。结果:16例患者在起搏条件下完成手术,其中10例术后起搏器继续工作,直至生命体征平稳后拔管,1例患者起搏器依赖,予永久心脏起搏器安装术后拔管;6例患者临时起搏器处于备而未用状态;所有患者均安全地度过了围手术期。结论:合并缓慢心律失常的非心脏手术患者围手术期临时心脏起搏器安装术十分必要,提高了患者围手术期的安全性。

  7. Persistence of left supracardinal vein in an adult patient with heart-hand syndrome and cardiac pacemaker.

    Science.gov (United States)

    Nemec, Jan; Heifetz, Steven

    2008-01-01

    A patient with a sporadic heart-hand syndrome, which includes thumb hypoplasia, septum primum atrial septal defect, and cleft mitral valve is described. During attempted placement of a pacemaker lead, persistence of left superior and inferior vena cava was found in addition to the right-sided caval veins. This corresponds to persistence of left-sided supracardinal vein present during fetal development.

  8. German Roentgen Society statement on MR imaging of patients with cardiac pacemakers; Positionspapier der Deutschen Roentgengesellschaft (DRG) zu MR-Untersuchungen bei Patienten mit Herzschrittmachern

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, T. [German Red Cross Hospital Neuwied (Germany). Dept. of Diagnostic and Interventional Radiology; Luechinger, R. [Zuerich Univ. (Switzerland). Inst. for Biomedical Engineering; Barkhausen, J. [University Hospital Luebeck (Germany). Dept. of Radiology and Nuclear Medicine; Gutberlet, M. [Univ. Leipzig - German Heart Center Leipzig (Germany). Dept. of Diagnostic and Interventional Radiology; Quick, H.H. [University Hospital Essen (Germany). Erwin L. Hahn Inst. for MR Imaging, High Field and Hybrid MR Imaging; Fischbach, K. [University Hospital Magdeburg (Germany). Dept. of Radiology and Nuclear Medicine

    2015-09-15

    The aim of this paper is to inform physicians, especially radiologists and cardiologists, about the technical and electrophysiological background of MR imaging of patients with implanted cardiac pacemakers (PM) and to provide dedicated clinical practice guidelines how to perform MR exams in this patient group. The presence of a conventional PM system is not any more considered an absolute contraindication for MR imaging. The prerequisites for MR imaging on pacemaker patients include the assessment of the individual risk/benefit ratio as well as to obtain full informed consent about the off label character of the procedure and all associated risks. Furthermore the use of special PM-related (e.g. re-programming of the PM) and MRI-related (e.g. limitation of whole body SAR to 2 W/kg) precautions is required and needs to be combined with adequate monitoring during MR imaging using continuous pulsoximetry. MR conditional PM devices are tested and approved for the use in the MR environment under certain conditions, including the field strength and gradient slew rate of the MR system, the maximum whole body SAR value and the presence of MR imaging exclusion zones. Safe MR imaging of patients with MR conditional PM requires the knowledge of the specific conditions of each PM system. If MR imaging within these specific conditions cannot be guaranteed in a given patient, the procedure guidelines for conventional PM should be used. The complexity of MR imaging of PM patients requires close cooperation of radiologists and cardiologists.

  9. Percutaneously injectable fetal pacemaker: electronics, pacing thresholds, and power budget.

    Science.gov (United States)

    Nicholson, Adriana; Chmait, Ramen; Bar-Cohen, Yaniv; Zheng, Kaihui; Loeb, Gerald E

    2012-01-01

    We are developing a cardiac pacemaker that is designed to be implanted percutaneously into a fetus to treat complete heart block and consequent hydrops fetalis, which is otherwise fatal. One of the most significant considerations for this device is the technical challenges presented by the battery and charging system. The size of the device is limited to about 3 mm in diameter; batteries on this scale have very small charge capacities. The smaller capacity means that the device needs to be designed so that it uses as little current as possible and so that its battery can be recharged wirelessly. We determined the pacing thresholds for a simple relaxation oscillator that can be assembled from discrete, surface mount components and analyzed the power consumption of the device given different electrode configurations and stimulus parameters. An inductive recharging system will be required for some patients; it is feasible within the package constraints and under development.

  10. Experiência brasileira com uso de marcapasso cardíaco artificial: resultados atuais obtidos pelo Registro Brasileiro de Marcapassos - RBM Brazilian permanent cardiac pacemaker implantation experience: results obtained from the Brazilian Pacemaker Register's data

    Directory of Open Access Journals (Sweden)

    Roberto Costa

    1995-06-01

    Estimulação Cardíaca Artificial (DECA, com o apoio das empresas fornecedoras de marcapasso, e o respaldo do Ministério da Saúde permitiram que a implantação do RBM ocorresse da forma mais tranqüila possível. Hoje se dispõe de uma estatística nacional, volumosa e confiável, sobre a cirurgia de marcapasso no Brasil. As dificuldades enfrentadas estão relacionadas, principalmente, à estrutura individual de coleta de dados e a graus variados de familiaridade com o formulário, dificuldades estas que, com o tempo, tenderão a desaparecer.BACKGROUND: Brazilian Pacemaker Registry (RBM is a nationwide database to collect informations about all permanent pacemaker procedures performed in Brazil. It is a task force composed by Medical Society, Health Ministeryand Pacemaker Companies. OBJECTIVE: To report the data obtained from June to December, 1994. METHODS: From June 1 st to December 31,1994,4696 surgical procedures for permanent cardiac pacing were informed. These procedures were 3403 (72,5% initial implantations, 1053 (22.4% re-operations and in 240 cases this information was non-available. RESULTS: From 3403 initial implantations informed, 52.8% were males and 73.7% Caucasians. Preoperative dizziness or syncopes were refered in 76.4% and congestive heart failure in 85.0% of the patients. EKG evaluation showed 3rd degree atrioventricular (AV block in 57.7%, sick sinus syndrome in 13.9%, 2nd degree AV block in 13.8%, and high degree AV block and flutter or atrial fibrillation in 6.6% of patients. Chaga's disease was the prédominât ethiology (30.4%. Ventricular pacemakers were implanted in 83.6% of cases, atrioventricular in 16.1 % and atrial pacing in 0.3%. In the 1053 cases of re-operation, the interval between the initial implantation and the present procedure ranged from 1 month to 24 years (M=7.1 years. Pulse generator replacements were refered in 917 patients (87.0% of re-operation procedures, 65.7% of them at the end of life. Atrial lead replacement were

  11. Dosimetry of electromagnetic field exposure of an active armlet and its electromagnetic interference to the cardiac pacemakers using adult, child and infant models.

    Science.gov (United States)

    Yang, Hu; Wang, Yuduo; Yang, Jiangang; Wu, Tongning

    2016-01-01

    Wearable devices have been popularly used with people from different age groups. As a consequence, the concerns of their electromagnetic field (EMF) exposure to the human body and their electromagnetic interference (EMI) to the implanted medical devices have attracted many studies. The aim of this study was to evaluate the human exposure to the EMF of an active radiofrequency identification (RFID) armlet as well as its EMI to the cardiac pacemaker (CP). Different human models from various age groups were applied to assess the result variability. The scalar potential finite element method was utilized in the simulation. Local EMF exposure and the exposure to the central nerve system tissues were evaluated using different metrics. EMI to the CP was assessed in terms of the conducted voltage to the CP. The results from all the models revealed that the studied RFID armlet would not produce the EMF exposure exceeding the safety limits. The calculated interference voltage was highly dependent on the distance between the RFID armlet and the CP (i.e. the physical dimension of the individual model). The results proposed to evaluate the appropriateness of the current EMI measurement protocol for this kind of devices used by the infants.

  12. STUDY AND DESIGN OF EMBEDDED SOFTWARE FOR WIRELESS CARDIAC PACEMAKER TELEMONITORING TERMINAL%心脏起搏器无线监测终端的嵌入式软件研究与设计

    Institute of Scientific and Technical Information of China (English)

    朱凌云; 李世星

    2013-01-01

    For monitoring the working status and battery level of implantable cardiac pacemakers by remote wireless communication , it is very necessary to develop reliable wireless monitoring terminal .In hardware framework which uses S3C2440 of AM9 embedded system as the control core of the terminal , U-boot is selected to boot the operating system startup , and the Linux kernel is transplanted and cut accordingly . To deal with the problems of data processing and wireless transmission which is derived from high sampling rate of pacing signal , the pacing ECG data compression method in embedded condition based on improved LZ 77 algorithm, the multi-threading optimised processing in Linux and the data encryption technology based on RC 5 are emphatically studied .The QT program is employed to develop corresponding interperson-al interaction procedures , and the entire software system is implemented .Experimental results show that this embedded software can achieve pacing ECG real-time data acquisition , storage and remote wireless transmission , has a good human-computer interaction , and meet the needs of remote wireless monitoring of cardiac pacemakers .%为实现心脏起搏器工作状况与电池电量的远程监测,研制可靠的无线监测终端非常必要。在以AM9嵌入式系统S3C2440为终端控制核心的硬件框架下,采用U-Boot来引导操作系统的启动,并对Linux内核进行了相应的移植与剪裁;针对起搏信号高采样率给系统带来的数据处理和远程传输困难,重点研究基于LZ77改进算法的嵌入式环境下的起搏心电数据压缩、Linux下的多线程优化处理和基于RC5的数据加密技术;利用QT开发了相应的人际交互程序,并实现了整个软件系统。实验结果表明:该嵌入式软件能够实现起搏心电数据的实时采集、存储与远程无线传输,具有良好的人机交互功能,能够满足远程无线监测心脏起搏器的需要。

  13. The cardiac implantable electronic device power source: evolution and revolution.

    Science.gov (United States)

    Mond, Harry G; Freitag, Gary

    2014-12-01

    Although the first power source for an implantable pacemaker was a rechargeable nickel-cadmium battery, it was rapidly replaced by an unreliable short-life zinc-mercury cell. This sustained the small pacemaker industry until the early 1970s, when the lithium-iodine cell became the dominant power source for low voltage, microampere current, single- and dual-chamber pacemakers. By the early 2000s, a number of significant advances were occurring with pacemaker technology which necessitated that the power source should now provide milliampere current for data logging, telemetric communication, and programming, as well as powering more complicated pacing devices such as biventricular pacemakers, treatment or prevention of atrial tachyarrhythmias, and the integration of innovative physiologic sensors. Because the current delivery of the lithium-iodine battery was inadequate for these functions, other lithium anode chemistries that can provide medium power were introduced. These include lithium-carbon monofluoride, lithium-manganese dioxide, and lithium-silver vanadium oxide/carbon mono-fluoride hybrids. In the early 1980s, the first implantable defibrillators for high voltage therapy used a lithium-vanadium pentoxide battery. With the introduction of the implantable cardioverter defibrillator, the reliable lithium-silver vanadium oxide became the power source. More recently, because of the demands of biventricular pacing, data logging, and telemetry, lithium-manganese dioxide and the hybrid lithium-silver vanadium oxide/carbon mono-fluoride laminate have also been used. Today all cardiac implantable electronic devices are powered by lithium anode batteries.

  14. Clinical study of hospital infections in patients after implantation of permanent cardiac pacemaker%心脏永久置入起搏器患者医院感染的临床研究

    Institute of Scientific and Technical Information of China (English)

    黄荫浩; 顾青青; 陆齐; 黄荣; 吴翔

    2015-01-01

    OBJECTIVE To investigate the hospital infection and pathogenic characteristics of patients undergoing implantation of permanent cardiac pacemaker so as to provide certain clinical guidance .METHODS Retrospective a‐nalysis was conducted on clinical data of 240 patients undergoing permanent pacemaker implantation from Jan . 2011 to Jun .2014 .T he infection incidence ,clinical manifestations ,pathogenic characteristics and treatment meth‐ods were statistically summarized ,and the single factor analysis of variance and the multiple logistic regression a‐nalysis were used to analyze risk factors of infections in patients with permanent cardiac pacemaker .RESULTS A‐mong the 240 patients with permanent cardiac pacemaker ,pacemaker pocket infection occurred in 6 cases ,the in‐fection rate was 2 .5% ,including 4 cases (66 .7% ) with infections occurring at the first time of implantation and 2 cases (33 .3% ) after the replacement of pacemaker .In the 6 patients ,4 cases had the secretion culture positive for Staphylococcus epidermidis infection and the sensitivity to vancomycin was 100 .0% .Advanced age ,operation time ≥ 2 h ,operation frequency ≥ 2 times ,and pocket hematoma were risk factors of infection in patients with permanent pacemaker .CONCLUSION The main pathogen for infection in patients with permanent cardiac pacemak‐er was S .epidermidis ,sensitive to vancomycin .It is recommended to conduct reasonable treatment according to the risk factors of the patients .%目的:探讨心脏永久置入起搏器患者的医院感染与病原学特征,旨在为临床提供一定的指导。方法回顾性分析2011年1月-2014年6月240例实施永久起搏器置入术患者的临床资料,统计其感染的发生、临床表现、病原学特征、治疗方法,并采用单因素方差分析和多因素 logistic回归分析,分析心脏永久置入起搏器装置患者感染的危险因素。结果240例心脏永久置

  15. 超极化活化环核苷酸门孔通道与心脏生物起搏器(第二部分)%Hyperpolarization-activated Cyclic nucleotide-gated Channel and Cardiac Biological Pacemaker: Part Ⅱ

    Institute of Scientific and Technical Information of China (English)

    萧永福

    2005-01-01

    Abstract Hyperpolarization-activated cyclic-nucleotide-gated (HCN) channels in the heart modulate cardiac automaticity via the hyperpolarization-activated cation current (named If, Ih, or Iq ).Recent studies have unveiled the molecular identity of HCN (HCN14) channels. HCN isoforms are unevenly expressed in the heart, even in the sinoatrial node. Features of HCN currents have been characterized in cardiac and other types of cells or in cell lines transfected with the HCN isoforms. The factors modulating Ih and the physiological significance of HCN channels in the heart have been extensively investigated in recent years. The hypothesis for transplanting and/or creating biological pacemakers to replace diseased sinoatrial and/or atrioventricular nodes has been postulated and tested in animal models. Local overexpression of HCN2 channels in the left atrium or in the left conductive bundle branch of the left ventricle via gene delivery induced significant Ih and escape rhythms during vagal stimulation in canines. In addition, implantation of human mesenchymal stem cells with overexpression of HCN2 channels to the canine left ventricular wall was associated with formation of spontaneous escape rhythms of left-sided origin during vagal-stimulation-induced sinus arrest. This preliminary data suggest that the use of HCN channels may hold great promise in the development of biological pacemakers.

  16. Pacemakers charging using body energy.

    Science.gov (United States)

    Bhatia, Dinesh; Bairagi, Sweeti; Goel, Sanat; Jangra, Manoj

    2010-01-01

    Life-saving medical implants like pacemakers and defibrillators face a big drawback that their batteries eventually run out and patients require frequent surgery to have these batteries replaced. With the advent of technology, alternatives can be provided for such surgeries. To power these devices, body energy harvesting techniques may be employed. Some of the power sources are patient's heartbeat, blood flow inside the vessels, movement of the body parts, and the body temperature (heat). Different types of sensors are employed, such as for sensing the energy from the heartbeat the piezoelectric and semiconducting coupled nanowires are used that convert the mechanical energy into electricity. Similarly, for sensing the blood flow energy, nanogenerators driven by ultrasonic waves are used that have the ability to directly convert the hydraulic energy in human body to electrical energy. Another consideration is to use body heat employing biothermal battery to generate electricity using multiple arrays of thermoelectric generators built into an implantable chip. These generators exploit the well-known thermocouple effect. For the biothermal device to work, it needs a 2°C temperature difference across it. But there are many parts of the body where a temperature difference of 5°C exists - typically in the few millimeters just below the skin, where it is planned to place this device. This study focuses on using body heat as an alternative energy source to recharge pacemaker batteries and other medical devices and prevent the possibility of life-risk during repeated surgery.

  17. Pacemakers charging using body energy

    Directory of Open Access Journals (Sweden)

    Dinesh Bhatia

    2010-01-01

    Full Text Available Life-saving medical implants like pacemakers and defibrillators face a big drawback that their batteries eventually run out and patients require frequent surgery to have these batteries replaced. With the advent of technology, alternatives can be provided for such surgeries. To power these devices, body energy harvesting techniques may be employed. Some of the power sources are patient′s heartbeat, blood flow inside the vessels, movement of the body parts, and the body temperature (heat. Different types of sensors are employed, such as for sensing the energy from the heartbeat the piezoelectric and semiconducting coupled nanowires are used that convert the mechanical energy into electricity. Similarly, for sensing the blood flow energy, nanogenerators driven by ultrasonic waves are used that have the ability to directly convert the hydraulic energy in human body to electrical energy. Another consideration is to use body heat employing biothermal battery to generate electricity using multiple arrays of thermoelectric generators built into an implantable chip. These generators exploit the well-known thermocouple effect. For the biothermal device to work, it needs a 2°C temperature difference across it. But there are many parts of the body where a temperature difference of 5°C exists - typically in the few millimeters just below the skin, where it is planned to place this device. This study focuses on using body heat as an alternative energy source to recharge pacemaker batteries and other medical devices and prevent the possibility of life-risk during repeated surgery.

  18. [Management of pacemaker patients by bathtub ECG].

    Science.gov (United States)

    Mizukami, H; Togawa, T; Toyoshima, T; Ishijima, M

    1989-01-01

    We evaluated the efficacy of a new method for recording electrocardiogram (ECG) of pacemaker patients in bathtub (bathtub ECG). ECG from the pacemaker implanted patients in the bathtub with tap water was recorded through three silver/silver chloride electrodes (4 x 4 cm) fitted on the inside wall of bathtub. Electric signal was connected to the isolated amplifier and recorded on the strip chart recorder. Contrast to the conventional method for recording standard ECG, bathtub ECG does not require body surface electrodes and is recorded at patients home. Although the amplitude of bathtub ECG was reduced approximately to a quarter of standard ECG, cardiac arrhythmia can be easily interpreted by bathtub ECG. In patients with pacemaker system, the amplitude of the pacing pulse recorded by bathtub ECG was much larger than that of QRS complex recorded by standard ECG. Therefore, we conclude that bathtub ECG would be a suitable method to follow up patients with pacemaker system.

  19. Who Needs a Pacemaker?

    Science.gov (United States)

    ... this page from the NHLBI on Twitter. Who Needs a Pacemaker? Doctors recommend pacemakers for many reasons. ... help regulate your heartbeat after the procedure. You need to take certain heart medicines, such as beta ...

  20. Heart pacemaker - discharge

    Science.gov (United States)

    ... pacemaker can be used for patients with heart failure. It has three leads to help the heart beat in a more coordinated manner. Some pacemakers also can deliver electric shocks to the heart that can stop life-threatening ...

  1. Intrapericardial pacemaker in a 2-kilogram newborn.

    Science.gov (United States)

    Gil-Jaurena, Juan-Miguel; Castillo, Rafael; Rubio, Lorena

    2012-08-01

    A 2-kilogram child had a pacemaker implanted by a subxyphoid approach with the generator located under the rectus sheath. Days later, the battery eroded the abdominal wall and the peritoneum. The whole system was removed and a new one was implanted inside the pericardium on an emergent basis.

  2. Anesthetic Management of Placement Perpetual Pacemaker in Patients Undergoing Cardiac Surgery%安置永久起搏器患者心脏手术中的麻醉管理

    Institute of Scientific and Technical Information of China (English)

    李正凯

    2016-01-01

    目的:探讨安置永久起搏器患者心脏手术中的麻醉管理方法。方法选取我院2013年5月~2015年8月收治的永久起搏器且行心脏手术的患者。术前给予吗啡、东茛菪碱。冠心病患者术前2 h,给予口服地西泮片等药物,气管插管控制呼吸。术中监测患者收缩压(SBP)、舒张压(DBP)、平均动脉压(MAP)、心率(HR)、心电图(ECG)等情况,使用单级电刀、电凝,控制输出功率为25~35 J,短脉冲放电,关闭胸腔前均给予预防性放置临时起搏器。结果手术均顺利进行,6例患者控制起搏模式,其他患者起搏模式未见改变。结论掌握麻醉对永久起搏器的影响作用可降低危险性,提高手术的安全性。%Objective Discussion of permanent pacemaker implantation of cardiac surgery patients anesthesia management.Methods Selected permanent pacemaker cardiac surgery from May 2013 to August 2015 in our hospital. Preoperative morphine, scopolamine. Preoperative coronary heart disease 2 hours, given oral diazepam tablets and other drugs, intubated control breathing. Intraoperative monitoring of patients with systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), heart rate (HR), electrocardiogram (ECG), et al, using a single-stage electric knife, coagulation, try to control the output power of 25 to 35 J, short pulse discharge, all patients were treated with closed chest preventive placement of a temporary pacemaker. Results All patients were operated successfully performed in 6 patients control pacing mode. No changes were seen in patients with other pacing mode.ConclusionGrasp the inlfuence of anesthesia on a permanent pacemaker to reduce risk and improve the safety of surgery.

  3. Pacemaker, implanted cardiac defibrillator and irradiation: Management proposal in 2010 depending on the type of cardiac stimulator and prognosis and location of cancer; Pacemaker, defibrillateur et radiotherapie: propositions de conduite a tenir en 2010 en fonction du type de stimulateur cardiaque, du pronostic et du site du cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, P. [Service d' anesthesie reanimation, hopital Nord, centre hospitalier universitaire de Saint-etienne, 42055 Saint-etienne cedex 2 (France); Da Costa, A. [Service de cardiologie, hopital Nord, centre hospitalier universitaire de Saint-etienne, 42055 Saint-etienne cedex 2 (France); Marcy, P.Y. [Departement de radiologie, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Kreps, S. [Service de radiotherapie Corad, centre regional universitaire de cancerologie Henry-S.-Kaplan, hopital Bretonneau-2, CHU de Tours, boulevard Tonnelle, 37000 Tours (France); Angellier, G.; Marcie, S.; Bondiau, P.Y. [Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Departement de radiotherapie oncologie, centre CyberKnife, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Briand-Amoros, C. [Service de radiotherapie, hopital europeen Georges-Pompidou, 20, rue Leblanc, 75015 Paris (France); Thariat, J. [Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Departement de radiotherapie oncologie, centre CyberKnife, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); IBDC CNRS UMR 6543, centre Antoine-Lacassagne, universite Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France)

    2011-06-15

    Ionizing radiation may interfere with electric components of pacemakers or implantable cardioverter defibrillators. The type, severity and extent of radiation damage to pacemakers, have previously been shown to depend on the total dose and dose rate. Over 300,000 new cancer cases are treated yearly in France, among which 60% are irradiated in the course of their disease. One among 400 of these patients has an implanted pacemaker or defibrillator. The incidence of pacemaker and implanted cardioverter defibrillator increases in an ageing population. The oncologic prognosis must be weighted against the cardiologic prognosis in a multidisciplinary and transversal setting. Innovative irradiation techniques and technological sophistications of pacemakers and implantable cardioverter-defibrillators (with the introduction of more radiosensitive complementary metal-oxide-semiconductors since 1970) have potentially changed the tolerance profiles. This review of the literature studied the geometric, dosimetric and radiobiological characteristics of the radiation beams for high energy photons, stereotactic irradiation, proton-therapy. Standardized protocols and radiotherapy optimization (particle, treatment fields, energy) are advisable in order to improve patient management during radiotherapy and prolonged monitoring is necessary following radiation therapy. The dose received at the pacemaker/heart should be calculated. The threshold for the cumulated dose to the pacemaker/implantable cardioverter-defibrillator (2 to 5 Gy depending on the brand), the necessity to remove/displace the device based on the dose-volume histogram on dosimetry, as well as the use of lead shielding and magnet are discussed. (authors)

  4. Pacemakers and implantable cardioverter defibrillators - general and anesthetic considerations

    Directory of Open Access Journals (Sweden)

    Amy G. Rapsang

    2014-06-01

    Full Text Available A pacemaking system consists of an impulse generator and lead or leads to carry the electrical impulse to the patient's heart. Pacemaker and implantable cardioverter defibrillator codes were made to describe the type of pacemaker or implantable cardioverter defibrillator implanted. Indications for pacing and implantable cardioverter defibrillator implantation were given by the American College of Cardiologists. Certain pacemakers have magnet-operated reed switches incorporated; however, magnet application can have serious adverse effects; hence, devices should be considered programmable unless known otherwise. When a device patient undergoes any procedure (with or without anesthesia, special precautions have to be observed including a focused history/physical examination, interrogation of pacemaker before and after the procedure, emergency drugs/temporary pacing and defibrillation, reprogramming of pacemaker and disabling certain pacemaker functions if required, monitoring of electrolyte and metabolic disturbance and avoiding certain drugs and equipments that can interfere with pacemaker function. If unanticipated device interactions are found, consider discontinuation of the procedure until the source of interference can be eliminated or managed and all corrective measures should be taken to ensure proper pacemaker function should be done. Post procedure, the cardiac rate and rhythm should be monitored continuously and emergency drugs and equipments should be kept ready and consultation with a cardiologist or a pacemaker-implantable cardioverter defibrillator service may be necessary.

  5. 双腔心脏起搏器对缓慢性心律失常患者的应用效果及对心功能的影响%Effect of Dual Chamber Pacemaker on Cardiac Function in Patients With Chronic Cardiac Arrhythmia

    Institute of Scientific and Technical Information of China (English)

    张莹

    2016-01-01

    目的:探讨双腔心脏起搏器对缓慢性心律失常患者的应用效果及对心功能的影响。方法选取我院2013年3月~2015年11月收治的67例缓慢性心律失常患者,随机分组,对照组33例,观察组34例,对照组行单腔心脏起搏器植入治疗,观察组行双腔心脏起搏器植入治疗,观察比较两组应用效果及心功能变化情况。结果对照组的有效率为30.30%,观察组为73.53%,组间比较差异有统计学意义(P<0.05);观察组心率、心输出量、心脏指数均高于对照组,差异有统计学意义(P<0.05)。结论双腔心脏起搏器应用于缓慢性心律失常患者,可有效改善患者心功能,提高应用有效率。%Objective To investigate the effect of dual chamber pacemaker on cardiac function in patients with chronic cardiac arrhythmia.Methods 67 patients with chronic arrhythmia were treated in our hospital from March 2013 to November 2015, they were randomly divided into two groups, 33 cases in the control group and 34 cases in the observation group. Patients in the control group were treated with single chamber pacemaker implantation, and the observation group was treated with double chamber pacemaker implantation. We observed and compared the effects of the two groups and the changes of cardiac function. Results The effective rate of control group was 30.30%, the observation group was 73.53%, there was significant difference between the two groups (P<0.05), the heart rate, cardiac output and cardiac index in the observation group were higher than those in the control group, the difference was statistically significant (P<0.05).Conclusion Dual chamber pacemaker used in patients with slow arrhythmia, can effectively improve the patient's cardiac function, improve the efifciency of the application.

  6. Modern pacemaker therapy

    Directory of Open Access Journals (Sweden)

    Mijatov Milan

    2010-01-01

    Full Text Available Introduction. Pacemakers are devices that modern medicine and cardiology cannot be imagined without. The technique of implantation comes to surgical procedure where all principles of asepsis and antisepsis have to be respected. Although some complications do happen, they are rather rare. Results. After the implantation of the device, the patient is not handicapped (unless the heart was additionally damaged. On the contrary, the patient returns to his work and functions normally within his family in most of the cases. The first medical appointment is scheduled a month after the implantation and the following are three and six months after. Types of devices. Today there are „new types of electrostimulation”- implantable cardioverter defibrillators and multisite electrostimulators. The former is implanted in patients at high risk of sudden cardiac death and the latter in patients with heart failure and left bundle branch block. Owing to these devices, the sudden cardiac death can be prevented successfully and the quality of a patient’s life is improved.

  7. Rapid rehabilitation nursing of cardiac pacemaker implantation andeffectiveperioperativeapplication%快速康复护理在心脏起搏器植入围手术期运用及成效

    Institute of Scientific and Technical Information of China (English)

    周美灵

    2016-01-01

    Objective Explore rapid rehabilitation the rapy for patieants with cardiac pacemaker impiantation for perioperative perid nursing mode effect of clinical nursing research. Methods Choice in recent years in our hospital in patients undergoing cardiac pacemaker implantation and 88 cases,randomly assigned each 44 cases of control group and observation group control group using conventional nursing mode implement rapid rehibitation nursing observation group,compared two group of patients with clinical nuring effect. Rusults The observation indexes after observation group of clinical nuring and complications were significantly better than the control group, two groups of patients with clinical nursing effect, compared with significant statistical difference(P<0.05). Conclusion Rapid rehabilitation nursing for patients with cardiac pacemaker implantation in the perioperative period clinical nursing effect is very obvious, higher application value.%目的:探讨快速康复护理模式用于心脏起搏器植入术患者围术期内临床护理效果研究。方法选择在我院就诊接受心脏起搏器植入术的患者88例,随机分对照组和观察组各44例,对照组采用常规护理模式,观察组实施快速康复护理,比较分析两组患者的临床护理效果。结果观察组临床护理后各项观察指标情况和并发症发生率均明显优于对照组,两组患者临床护理效果对比具有明显的统计学差异(P<0.05)。结论快速康复护理对接受心脏起搏器植入术患者在围术期内实施临床护理效果非常明显,应用价值较高。

  8. A novel non invasive measurement of hemodynamic parameters: Comparison of single-chamber ventricular and dual-chamber pacemaker

    Directory of Open Access Journals (Sweden)

    Ingrid M. Pardede

    2008-03-01

    Full Text Available We carried out a cross sectional study to analyze hemodynamic parameters of single-chamber ventricular pacemaker compared with dual-chamber pacemaker by using thoracic electrical bioimpedance monitoring method (Physio Flow™ - a novel simple non-invasive measurement. A total of 48 consecutive outpatients comprised of 27 single chamber pacemaker and 21 dual chamber were analyzed. We measured cardiac parameters: heart rate, stroke volume index, cardiac output index, estimated ejection fraction, end diastolic volume, early diastolic function ratio, thoracic fluid index, and systemic parameters: left cardiac work index and systemic vascular resistance index. Baseline characteristic and pacemaker indication were similar in both groups. Cardiac parameters assessment revealed no significant difference between single-chamber pacemaker and dual-chamber pacemaker in heart rate, stroke volume index, cardiac index, estimated ejection fraction, end-diastolic volume, thoracic fluid index. There was significantly higher early diastolic function ratio in single-chamber pacemaker compared to dual-chamber pacemaker: 92% (10.2-187.7% vs. 100.6% (48.7-403.2%; p=0.006. Systemic parameters assessment revealed significantly higher left cardiac work index in single-chamber group than dual-chamber group 4.9 kg.m/m² (2.8-7.6 kg.m/m² vs. 4.3 kg.m/m² (2.9-7.2 kg.m/m²; p=0.004. There was no significant difference on systemic vascular resistance in single-chamber compared to dual-chamber pacemaker. Single-chamber ventricular pacemaker provides similar stroke volume, cardiac output and left cardiac work, compared to dual-chamber pacemaker. A non-invasive hemodynamic measurement using thoracic electrical bioimpedance is feasible for permanent pacemaker outpatients. (Med J Indones 2008; 17: 25-32Keywords: Permanent pacemaker, single chamber, dual chamber, thoracic electrical bioimpedance, hemodynamic parameter

  9. 氦氖激光照射对心脏起搏器手术切口术后的临床研究%The clinical research of helium-neon laser irradiation on cardiac pacemaker operative incision healing

    Institute of Scientific and Technical Information of China (English)

    李起栋; 洪钰锟; 郭娟; 周继光

    2013-01-01

    Objective To observe the effects of helium-neon laser local irradiation on cardiac pacemaker operative incision healing.Methods 368 patients who implanted a permanent cardiac pacemaker were divided into irradiation group (186 patients) and control group (182 patients).Patients in control group were treated with antibiotics and change of dressing,and patients in irradiation group were treated added with helium-neon laser local irradiation 24 hours after operation.Wound pain,infection rate,pocket hematoma occurring rate and incision healing time of the two groups were compared.Adverse reaction of irradiation group was observed.Results Incision pain is lighter in irradiation group than in control group.pocket hematoma occurring rate,Incision infection rate and Pacemaker pocket infection rate in irradiation group is lower than those in control group (P < 0.05).Average incision healing time in irradiation group is lower than that in control group (P < 0.01).Conclusion The application of helium-neon laser local irradiation on pacemaker implantation patients can reduce postoperative pain,reduce incision and pocket infection and pocket hematoma incidence,accelerate the healing of operation incision,it is safe.%目的 观察氦氖激光照射对心脏起搏器切口术后的影响.方法 植入永久性心脏起搏器的368例,分为照射组186例及对照组182例.对照组给予抗生素及换药等处理,照射组治疗同对照组外,术后24 h加行氦氖激光局部照射.比较两组术后切口疼痛的情况、切口感染率、囊袋血肿发生率及切口愈合时间,观察照射组不良反应发生情况.结果 术后照射组疼痛程度较对照组轻,血肿发生率、切口感染率及囊袋感染率均低于对照组(P<0.05),照射组平均手术切口愈合时间短于对照组(P<0.01).结论 氦氖激光局部照射应用于起搏器植入患者,能减轻术后疼痛,降低切口和囊袋感染率及囊袋血肿率,加快手术切口愈合,使用安全.

  10. The effects of cardiac pacemaker combing bisoprolol on brady-tachy arrhythmia syndrome%心脏起搏器联合比索洛尔治疗慢快综合征的疗效

    Institute of Scientific and Technical Information of China (English)

    吴辉; 吕志阳; 李稳慧; 杨俊; 丁家望; 李松; 杨简; 彭家芹; 陈勇; 童晓红; 董武松

    2013-01-01

    目的 评价置入永久性心脏起搏器联合比索洛尔治疗慢快综合征患者的疗效.方法 纳入慢快综合征患者45例,均接受永久性心脏起搏器置入并联合比索洛尔治疗,3个月后分析患者临床症状、心电图和超声心动结果对临床疗效进行评价,同时采用SF-36量表对患者生活质量进行评价.结果 经永久性心脏起搏器联合比索洛尔治疗后,所有患者与治疗前相比临床症状减轻,严重心律失常发作频率显著下降(心动过缓:48.89% vs.0;心动过速:33.33% vs.0),心率更加平稳[(65.3±7.2)次/分 vs.(43.5±6.7)次/分],心功能显著改善[NYHA分级:(1.57±0.42) vs.(2.31±0.35)];SF-36量表评分各项指标均有明显改善(P<0.01).结论 永久性心脏起搏器联合比索洛尔可改善慢快综合征患者预后,提高生活质量.%Objective To review the curative effect of permanent cardiac pacemaker combing bisoprolol on brady—tachy arrhythmia syndrome. Methods The patients ( n=45 ) with brady-tachy arrhythmia syndrome were selected and given the implantation of permanent cardiac pacemaker combing bisoprolol treatment. After 3 months, the curative effect was reviewed through counting and analyzing clinical symptoms and results of electrocardiogram ( ECG ) and echocardiogram. The quality of life in the patients was reviewed by applying SF—36 scale. Results After the treatment, the clinical symptoms were relieved in all patients, seizure frequency of severe arrhythmia decreased significantly ( bradyarrhythmia: 48.89% vs. 0; tachycardia: 33.33% vs. 0 ) , heart rate was more smooth [ ( 65.3 ± 7.2 ) vs. ( 43.5 ± 6.7 ) ], and heart function was significantly improved [NYHA grading: ( 1.57 ± 0.42 ) vs. ( 2.31 ± 0.35 ) ]. The scores of SF-36 scale showed all indexes were significantly improved ( P<0.01 ) . Conclusion Permanent cardiac pacemaker combing bisoprolol can ameliorate the prognosis and improve the quality of life in the patients with brady

  11. Correlação entre classe funcional e qualidade de vida em usuários de marcapasso cardíaco Correlation between functional class and quality of life among cardiac pacemaker users

    Directory of Open Access Journals (Sweden)

    TMB Cunha

    2007-10-01

    Full Text Available INTRODUÇÃO: Os crescentes avanços tecnológicos desenvolvidos para o tratamento de distúrbios de condução cardíaca vêm proporcionando aos pacientes melhores condições de vida. As escalas de classificação funcional e questionários de qualidade de vida (QV constituem uma forma suplementar de avaliação dos aspectos físicos, emocionais e funcionais dos pacientes. Entretanto, permanece a seguinte questão: existe correlação entre a classe funcional (CF e a percepção da QV em usuários de marcapasso (MP? OBJETIVO: O objetivo do estudo foi avaliar se existe correlação entre classe funcional (CF e QV em portadores de MP cardíaco definitivo. MÉTODOS: Foram avaliados 14 usuários de MP. Para avaliar CF, foi utilizada a escala de atividade específica proposta por Goldman, e, com objetivo de avaliação da QV, foi aplicado o questionário Aquarel associado ao SF-36. Com o objetivo de verificar se existe correlação entre as variáveis, foi aplicado o teste de correlação de Spearman, considerando como significativo aINTRODUCTION: Growing technological progress in treating patients with heart conduction disturbances has provided such patients with better life conditions. Functional classification (FC scales and quality of life (QOL questionnaires are additional means for evaluating patients' physical, emotional and functional characteristics. However, the question remains as to whether there is any association between FC and perception of QOL among pacemaker users. OBJECTIVE: To evaluate whether there is any correlation between FC and QOL among definitive cardiac pacemaker users. METHOD: Fourteen pacemaker users were evaluated. To assess FC, the specific activity scale proposed by Goldman was used. To evaluate QOL, the Aquarel questionnaire was used in association with SF-36. The Spearman correlation test was applied to investigate whether there was any association between the variables, considering p< 0.05 to be significant. The

  12. MRI-conditional pacemakers: current perspectives

    Directory of Open Access Journals (Sweden)

    Ferreira AM

    2014-05-01

    Full Text Available António M Ferreira,1,2 Francisco Costa,2 António Tralhão,2 Hugo Marques,3 Nuno Cardim,1 Pedro Adragão1,2 1Cardiology Department, Hospital da Luz, 2Cardiology Department, Hospital Santa Cruz- CHLO, 3Radiology Department, Hospital da Luz, Lisbon, Portugal Abstract: Use of both magnetic resonance imaging (MRI and pacing devices has undergone remarkable growth in recent years, and it is estimated that the majority of patients with pacemakers will need an MRI during their lifetime. These investigations will generally be denied due to the potentially dangerous interactions between cardiac devices and the magnetic fields and radiofrequency energy used in MRI. Despite the increasing reports of uneventful scanning in selected patients with conventional pacemakers under close surveillance, MRI is still contraindicated in those circumstances and cannot be considered a routine procedure. These limitations prompted a series of modifications in generator and lead engineering, designed to minimize interactions that could compromise device function and patient safety. The resulting MRI-conditional pacemakers were first introduced in 2008 and the clinical experience gathered so far supports their safety in the MRI environment if certain conditions are fulfilled. With this technology, new questions and controversies arise regarding patient selection, clinical impact, and cost-effectiveness. In this review, we discuss the potential risks of MRI in patients with electronic cardiac devices and present updated information regarding the features of MRI-conditional pacemakers and the clinical experience with currently available models. Finally, we provide some guidance on how to scan patients who have these devices and discuss future directions in the field. Keywords: pacemakers, magnetic resonance imaging, MRI, MRI-conditional devices, safety

  13. Effects of irradiation on the components of implantable pacemakers

    CERN Document Server

    Kawamura, S; Kuga, N; Shiba, T; Hirose, T; Fujimoto, H; Toyoshima, T; Hyodo, K; Matoba, M

    2003-01-01

    The purpose of this study was to examine the effects of irradiation on implantable pacemaker components. The pacemaker was divided into three components: lead wire and electrode, battery, and electrical circuit, and each component was irradiated by X-ray and electron beams, respectively. The pacemaker parameters were measured by both telemetry data of the programmer and directly measured data from the output terminal. The following results were obtained. For the lead wire and electrode, there was no effect on the pacemaker function due to irradiation by X-ray and electron beams. In the case of battery irradiation, there was no change in battery voltage or current up to 236 Gy X-ray dose. In the electrical circuit, the pacemaker reverted to the regular beating rate (fixed-rate mode) immediately after the start of X-ray irradiation, and it continued in this mode during irradiation. In patients with their own heartbeat rhythm, changing to the fixed-rate mode may cause dangerous conditions such as ventricular fib...

  14. Successful management of late right ventricular perforation after pacemaker implantation

    Directory of Open Access Journals (Sweden)

    Amir K Bigdeli

    2010-01-01

    Full Text Available Amir K Bigdeli1, Andres Beiras-Fernandez1, Ingo Kaczmarek1, Christian Kowalski2, Michael Schmoeckel1, Bruno Reichart11Department of Cardiac Surgery, 2Department of Anesthesiology, Ludwig-Maximilians University, Munich, GermanyAbstract: Complications of pacemaker implantation include myocardial perforation, venous thrombosis, vegetations of the tricuspid valve or pacing lead, and tricuspid regurgitation. We report a patient presenting with a case of delayed ventricular lead perforation through the right ventricle. The lead was uneventfully extracted under transesophageal echocardiographic observation in the operating room with cardiac surgery backup.Keywords: pacemaker, lead perforation, complication

  15. 心脏临时起搏器在颅外颈动脉支架置入术中的应用观察%Clinical application of transvenous temporary cardiac pacemaker in performing extra-cranial carotid angiography and stent implantation

    Institute of Scientific and Technical Information of China (English)

    刘娟; 姚国恩; 周华东; 蒋晓江; 陈乔

    2012-01-01

    Objective To assess the safety and effectiveness of transvenous temporary cardiac pacemaker in preventing hemodynamic instability occurred during the perioperative period of extra-cranial carotid angiography and stent implantation. Methods Preoperative install of temporary cardiac pacemaker via left femoral vein was carried out in 41 patients who were at high risk for developing hemodynamic instability, which was followed by extra-cranial carotid angiography and stent implantation. The pacing rhythm of the pacemaker was fixed at 60 beats/min. During and after the procedure the patients were under close observation for the signs of discomfort symptoms as well as the changes in blood pressure and heart rate. The working condition of the pacemaker was also monitored. Results All the installed pacemakers were technically and hemodynamically effective in producing electrical ventricular responses in all 25 patients who had received balloon dilatation of carotid in advance. Transient pacemaker activation appeared in 25 patients. The longest activation time was one day. During pacemaker activation, one patient developed symptomatic hypotension. The longest duration of hypotension lasted for 4 days. No pacemaker-related or procedure-related complications occurred. Conclusion Hemodynamic instability is a common complication occurred during perioperative period of extra-cranial carotid angiography and stent implantation. As a prophylactic measure, preoperative placement of temporary cardiac pacemaker can promptly and effectively correct the hemodynamic disorders and prevent perioperative complications such as stroke, etc. Therefore, this technique is worth employing in clinical practice, and it is especially useful for patients with high risks. (J Intervent Radiol, 2012, 21: 154-157)%目的 观察心脏临时起搏器在颅外颈动脉支架围手术期防治血流动力学紊乱的有效性、安全性.方法 41例行颅外颈动脉支架术高危

  16. 高龄患者永久心脏起搏器植入术41例临床分析%Clinical analysis of permanent cardiac pacemaker implanted in 41 elderly patients

    Institute of Scientific and Technical Information of China (English)

    周缨; 谷惠敏; 陈宗建

    2011-01-01

    Objective To analyse the clinical characteristics of elderly patients with permanent cardiac pacemaker implanted. Methods To retrospectively analyze 41 elderly patients( ≥80 years) with permanent pacemakers implantation. Observing the clinical symptoms, bradyarrhythmia category, pacing mode, intraoperative pacing parameters,intraoperative and postoperative complications. Results All patients were operated successfully. Pacing modes were,VVI 29 cases,VVIR 2 cases,DDD 9 cases and DDDR 1 case. Ventricular electrode located in right ventricular apical pacing. Atrial electrode located right heart ear. During the operateing, severe complications did not happen such as heart perforation, malignant arrhythmia. One case of postoperative dislocation electrode and one case of pocket hematocele were observed. After treatment, they were cured, no infection and pacemaker syndrome happened. 6 patients died during follow-up, postoperative from two months to 6 years. Conclusion Pacing therapy in elderly patients is good. Surgical risk was not increased.%目的:分析高龄患者植入永久心脏起搏器的临床特点及并发症发生情况。方法对植入永久心脏起搏器的41例高龄(≥80岁)患者临床资料进行回顾性分析,观察临床症状、缓慢心律失常的类型、起搏模式、术中起搏参数、术中和术后并发症等。结果41例患者手术均成功完成。起搏模式:心室单腔起搏器VVI 29例、VVIR 2例、房室双腔起搏器DDD 9例,房室双腔频率适应性起搏器DDDRI例;心室电极位于右室心尖部,心房电极位于右心耳。术中无心脏穿孔、恶性心律失常等严重并发症发生;术后发生电极脱位1例、囊袋血肿1例,经治疗后治愈,无感染、起搏器综合征发生。随访中死亡6例,死于术后2月至6年。结论高龄患者植入心脏起搏器,手术风险并不增加,治疗效果较好。

  17. Equivalence randomized controlled study of Shen Xian liter artificial cardiac pacemaker pulse and impact on quality of life in patients with arrhythmia%参仙升脉口服液联合人工心脏起搏器对缓慢性心律失常患者生活质量影响等效性随机平行对照研究

    Institute of Scientific and Technical Information of China (English)

    刘桂勇; 潘迪光; 蒋靖波; 李斌; 路华; 李薇; 张伟; 伍于斌

    2016-01-01

    目的:应用等效性随机平行对照法分析参仙升脉口服液联合人工心脏起搏器对缓慢性心律失常患者生活质量影响。方法选取从2015年1月到2015年8月入院治疗的50例缓慢性心律失常患者作为研究对象。按照入院顺序随机分为治疗组25例与对照组25例。两组患者均植入永久心脏起搏器,治疗组患者应用参仙升脉口服液治疗,对照组患者应用对照安慰剂治疗。对比两组患者治疗前后及两组患者间心室起搏频率、基础心率、电池容量、起搏电压、阻抗、阈值、脉宽和感知电流等指标变化情况,评估不同措施对于患者预后生活质量的影响。结果治疗组患者治疗后起搏器参数及心功能水平均优于对照组,差异具有统计学意义( P <0.05)。治疗组患者治疗后生活质量各指标均优于对照组,差异具有统计学意义( P <0.05)。结论临床应用参仙升脉口服液联合植入永久性人工心脏起搏器治疗缓慢性心律失常患者,可大大改善起搏器功能与降低心脏起搏率,具有延长起搏器寿命与改善患者预后的效果,临床值得广泛推广应用。%Objective Randomized parallel group equivalence analysis shenxian liter artificial cardiac pacemaker pulse and impact on quality of life in patients with arrhythmia. Methods From January 2015 to August 2015,50 patients with arrhythmia were selected as research objects,who were randomly divided into treatment group and control group,25 cases in each group. Patients were implanted a permanent pace-maker. Treatment group were treated with oral application parameters cents liter vein treatment,the control group with placebo. Ventricular pacing rate,basic heart rate,battery capacity,pacing voltage,impedance,threshold,pulse and other indicators of the current perception changes be-tween the two groups were compared and evaluate influence of different measures on the prognosis of patients

  18. Intra-SA-nodal pacemaker shifts induced by autonomic nerve stimulation in the dog.

    Science.gov (United States)

    Goldberg, J M

    1975-10-01

    Pacemaker shifts in the canine heart were inferred during stimulation of thoracic cardiac nerves and following norepinephrine from changes in the initial site of activation of bipolar electrodes sutured over the rostral, middle, and caudal regions of the sinus node, over the internodal pathways, and His bundle. During control periods, pacemaker activity was localized within the sinoatrial (SA) node 87% of the time, with the middle electrode most frequently showing initial activation. Stimulation of the right-sympathetic nerves enhanced sinus node pacemaker dominance, shifting it rostrally within the node. Right-vagal stimulation shifted the pacemaker caudally within the SA node, to nonnodal sites, and to the lower atrioventricular node and His bundle. Left-sympathetic stimulation shifted the pacemaker caudally within the sinus node and enhanced pacemaker activity in the vicinity of the internodal pathway electrodes and His bundle. Dispersion of pacemaker activity was particularly apparent during stimulation of the ventrolateral cervical cardiac nerve. Stimulation of the left-vagal nerves produced effects similar to those of the left-sympathetic nerves. Norepinephrine enhanced pacemaker activity particularly in the rostral region of the sinus node. Slight shifts in pacemaker activity within the sinus node produced changes in pattern of atrial excitation.

  19. Subacute Right Ventricle Perforation by Pacemaker Lead Presenting with Left Hemothorax and Shock

    Directory of Open Access Journals (Sweden)

    Julianne Nichols

    2015-01-01

    Full Text Available Cardiac perforation by pacemaker is a rare but potentially fatal complication. Acute perforations occurring within twenty-four hours of insertion of pacemaker can lead to hemopericardium, cardiac tamponade, and death. Hemothorax occurring as an acute complication of pacemaker insertion is reported but extremely rare. Previously, hemothorax and shock as a subacute complication following pacemaker insertion have not been reported. We report the case of an 85-year-old patient who presented with shock from hemothorax caused by pacemaker perforation, two weeks after insertion. Device interrogation showed normal function. Chest X-ray and echocardiogram missed lead dislocation and the diagnosis was made on computed tomogram (CT of the chest. Following surgical repair, a new ventricular pacemaker was placed transvenously in the right ventricular septum. This case illustrates that CT scan of the chest should be performed in all patients in whom cardiac perforation by pacemaker is suspected but not diagnosed on chest X-ray and echocardiogram. Normal functioning of pacemaker on device interrogation does not exclude perforation.

  20. OPTOGENETICS: A NOVEL APPROACH IN PACING HAERT TISSUE AND ENGENDER PROPAGATING CARDIAC IMPULSES

    Directory of Open Access Journals (Sweden)

    Pasam Naga Abhinay

    2012-04-01

    Full Text Available The cardiac pacemaker controls the rhythmicity of heart contractions and these can be substituted by battery-operated devices as last resource. Optogenetics involves insertion of light-sensitive proteins into human embryonic stem cell to encode DNA making mammalian tissues light-sensitive. The first discovered protein of this type is Channelrhodopsin2 (ChR2, which is widely used in neuroscience. The limitation of electrical stimulation of heart, a standard technique can be overcome by using ChR2.The various methods involved in optogenetics and energy needs were discussed in this section. Initially, optogenetics is confined only to neuronal system, later on extended to heart and other organs. This method involves precise localized stimulation and constant prolonged depolarization of cardiomyocytes and cardiac tissue resulting in alterations of pacemaking, Ca2+ homeostasis, electrical coupling and arrhythmogenic spontaneous extra beats.

  1. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard;

    2014-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  2. A novel quantitative explanation for the autonomic modulation of cardiac pacemaker cell automaticity via a dynamic system of sarcolemmal and intracellular proteins.

    Science.gov (United States)

    Maltsev, Victor A; Lakatta, Edward G

    2010-06-01

    Classical numerical models have attributed the regulation of normal cardiac automaticity in sinoatrial node cells (SANCs) largely to G protein-coupled receptor (GPCR) modulation of sarcolemmal ion currents. More recent experimental evidence, however, has indicated that GPCR modulation of SANCs automaticity involves spontaneous, rhythmic, local Ca(2+) releases (LCRs) from the sarcoplasmic reticulum (SR). We explored the GPCR rate modulation of SANCs using a unique and novel numerical model of SANCs in which Ca(2+)-release characteristics are graded by variations in the SR Ca(2+) pumping capability, mimicking the modulation by phospholamban regulated by cAMP-mediated, PKA-activated signaling. The model faithfully predicted the entire range of physiological chronotropic modulation of SANCs by the activation of beta-adrenergic receptors or cholinergic receptors only when experimentally documented changes of sarcolemmal ion channels are combined with a simultaneous increase/decrease in SR Ca(2+) pumping capability. The novel numerical mechanism of GPCR rate modulation is based on numerous complex synergistic interactions between sarcolemmal and intracellular processes via membrane voltage and Ca(2+). Major interactions include changes of diastolic Na(+)/Ca(2+) exchanger current that couple earlier/later diastolic Ca(2+) releases (predicting the experimentally defined LCR period shift) of increased/decreased amplitude (predicting changes in LCR signal mass, i.e., the product of LCR spatial size, amplitude, and number per cycle) to the diastolic depolarization and ultimately to the spontaneous action potential firing rate. Concomitantly, larger/smaller and more/less frequent activation of L-type Ca(2+) current shifts the cellular Ca(2+) balance to support the respective Ca(2+) cycling changes. In conclusion, our model simulations corroborate recent experimental results in rabbit SANCs pointing to a new paradigm for GPCR heart rate modulation by a complex system of

  3. Pacemaker activity of the human sinoatrial node: Role of the hyperpolarization-activated current, I-f

    NARCIS (Netherlands)

    A.O. Verkerk; A.C.G. van Ginneken; R. Wilders

    2009-01-01

    The mechanism of primary, spontaneous cardiac pacemaker activity of the sinoatrial node (SAN) has extensively been studied in several animal species, but is virtually unexplored in man. Understanding the mechanisms of human SAN pacemaker activity is important for developing new therapeutic approache

  4. 优化起搏参数在提高心脏再同步化治疗疗效中的作用%Study on significance of optimal pacemaker parameters in improving the efficacy of cardiac resynchronization therapy

    Institute of Scientific and Technical Information of China (English)

    谢芳; 何亚峰; 邓成钢; 程光辉; 张劲林

    2015-01-01

    Objective To evaluate the efficacy of cardiac resynchronization therapy( CRT)in treatment of patients with AV or VV delay. Methods Forty-nine patients with chronic heart failure received cardiac resynchronous pacing,followed-up for 1 week,3 months,6 months and 1 year,the delay of AV had been optimized by ultrasound cardiography,and delay of VV had been optimized by tissue Doppler imaging. Re-sults Heart function in 45 cases had been improved after CRT. According to NYHA classification,these patients had been improved from classⅢ˜IV to class II˜III,and their 6 minutes walking distance had also been increased. The LVEF index and VTI of left ventricular systolic func-tion had been improved( P <0. 01). Left ventricular diastolic filling time was also increased. In 3 months and 6 months after the treatment,left ventricular end diastolic diameter and volume were significantly smaller than those before the treatment( P <0. 01,P <0. 05). Mitral regurgita-tion had been reduced,and the standard deviation of 12 segments time to peak had been decreased from(139 ± 33)ms to(110 ± 40)ms( P <0. 01). Conclusion Optimization of the pacemaker parameters is needed in order to enhance the efficacy of CRT.%目的:探讨优化A-V、V-V间期在提高心脏再同步化治疗( CRT)中的疗效。方法49例CRT治疗的慢性心力衰竭患者,于术后1周、3个月、6个月和12个月进行个体化参数程控(在超声心动图指导下优化A-V间期,在组织多普勒显像下优化V-V间期),观察心脏同步性和心功能变化,达到CRT最佳治疗目的。结果临床症状:45例CRT后心功能得到改善,心功能NYHA分级,从Ⅲ˜Ⅳ级提高为Ⅱ˜Ⅲ级,6分钟步行距离增加。超声指标:反映左室收缩功能的指标左室射血分数( P <0.01)、血流速度积分( VTI)增加,反映左室舒张功能的指标左室舒张充盈时间延长,评价心腔大小指标改善,术后3、6个月左心室舒张末期内

  5. Management of radiation oncology patients with a pacemaker or ICD : A new comprehensive practical guideline in The Netherlands

    NARCIS (Netherlands)

    Hurkmans, Coen W.; Knegjens, Joost L.; Oei, Bing S.; Maas, Ad J. J.; Uiterwaal, G. J.; van der Borden, Arnoud J.; Ploegmakers, Marleen M. J.; van Erven, Lieselot

    2012-01-01

    Current clinical guidelines for the management of radiotherapy patients having either a pacemaker or implantable cardioverter defibrillator (both CIEDs: Cardiac Implantable Electronic Devices) do not cover modern radiotherapy techniques and do not take the patient's perspective into account. Availab

  6. Dual chamber pacemaker in the treatment of paroxysmal atrial fibrillation

    Directory of Open Access Journals (Sweden)

    Rađen Goran

    2005-01-01

    Full Text Available Background. Atrial fibrillation is the most frequent cardiac dysrhythmia. The aim of this study was to show the role and the efficacy of a dual chamber pacemaker with the algorithm of atrial dynamic overdrive, in the suppression of paroxysmal atrial fibrillation. Case report. A woman with a classical bradycardia-tachycardia syndrome, and frequent attacks of atrial fibrillation, underwent the implantation of a single chamber permanent pacemaker (VVI. Pacemaker successfully treated the episodes of symptomatic bradycardia, but the patient had frequent attacks of atrial fibrillation, despite the use of different antiarrhythmic drugs, which she did not tolerate well. The decision was made to reimplant a permanent dual chamber pacemaker with the algorithm of atrial dynamic overdrive. The pacemaker was programmed to the basic rate of 75/min, while rate at rest was 55/min. In addition, sotalol was administered. After three months, the patient became asymptomatic with only 4 short − term episodes of atrial fibrillation, and a high level of atrial pacing (99%. Conclusion. In selected patients with bradycardia−tachycardia syndrome, atrial-based pacing seemed to be very effective in reducing the incidence of paroxysmal atrial fibrillation.

  7. Patients exposure from fluoroscopic guided pacemaker implantation procedures

    Energy Technology Data Exchange (ETDEWEB)

    Alkhorayef, M.; Babikir, E. [King Saud University, College of Applied Sciences, Radiological Sciences Department, P. O. Box 10219, Riyadh 11433 (Saudi Arabia); Sulieman, A. [Prince Sattam bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, P. O. Box 422, Alkharj 11942 (Saudi Arabia); Daar, E. [University of Jordan, Faculty of Science, Department of Physics, Amman 11942 (Jordan); Alnaaimi, M.; Alduaij, M. [Kuwait Cancer Control Centre, Department of Nuclear Medicine, Shwiekh (Kuwait); Bradley, D., E-mail: malkhorayef@ksu.edu.sa [University of Surrey, Centre for Nuclear and Radiation Physics, Guildford, Surrey, GU2 7XH (United Kingdom)

    2016-10-15

    A pacemaker, which is used for heart re synchronization with electrical impulses, is used to manage many clinical conditions. Recently, the frequency of the pacemaker implantation procedures increased 50% worldwide. During this procedure, patients and staff can be exposed to excessive radiation exposure. Wide range of doses was reported in previous studies, suggesting that optimization of this procedure is not fulfilled yet. This study aims to evaluate the patient and staff radiation doses during cardiac pacemaker procedure and quantify the patient effective dose. A total of 145 procedures were performed for five pacemakers procedures (VVI, VVIR, VVD, VVDR and DDDR) two hospitals were evaluated. Patients doses were measured using the kerma-area product meter. Effective doses were estimated using software based on Monte Carlo simulation from National Radiological Protection Board. The effective dose values were used to estimate the cancer risk from pacemaker procedure. Patients demographic data, exposure parameters for both fluoroscopy and radiography were quantified. The mean patients doses (Gy. cm{sup 2}) for VVI, VVIR, VVD, VVDR and DDDR was 1.52±0.13 (1.43-1.61), 3.28±2.34 (0.29-8.73), 3.04±1.67 (1.57-4.86), 6.04±2.326 and 19.2±3.6 (5.43-30.2), respectively, per procedure. The overall patients effective dose is 1.1 mSv per procedure. (Author)

  8. Sikkerhed af magnetisk resonans-skanning hos patienter med pacemaker og implanterbar defibrillator

    DEFF Research Database (Denmark)

    Al-Sabagh, Kifah Hekmat; Christensen, Britta Ege; Thøgersen, Anna Margrethe;

    2010-01-01

    INTRODUCTION: The presence of a cardiac implantable device is ICD considered an absolute contraindication to magnetic resonance imaging (MRI). The purpose of this study was to evaluate the safety of performing MRI in patients with cardiac pacemakers and ICDs that had a compelling clinical need...

  9. Pacemaker Use Following Heart Transplantation

    Science.gov (United States)

    Mallidi, Hari R.; Bates, Michael

    2017-01-01

    Background: The incidence of permanent pacemaker implantation after orthotopic heart transplantation has been reported to be 2%-24%. Transplanted hearts usually exhibit sinus rhythm in the operating room following reperfusion, and most patients do not exhibit significant arrhythmias during the postoperative period. However, among the patients who do exhibit abnormalities, pacemakers may be implanted for early sinus node dysfunction but are rarely used after 6 months. Permanent pacing is often required for atrioventricular block. A different cohort of transplant patients presents later with bradycardia requiring pacemaker implantation, reported to occur in approximately 1.5% of patients. The objectives of this study were to investigate the indications for pacemaker implantation, compare the need for pacemakers following bicaval vs biatrial anastomosis, and examine the long-term outcomes of heart transplant patients who received pacemakers. Methods: For this retrospective, case-cohort, single-institution study, patients were identified from clinical research and administrative transplant databases. Information was supplemented with review of the medical records. Standard statistical techniques were used, with chi-square testing for categorical variables and the 2-tailed t test for continuous variables. Survival was compared with the use of log-rank methods. Results: Between January 1968 and February 2008, 1,450 heart transplants were performed at Stanford University. Eighty-four patients (5.8%) were identified as having had a pacemaker implanted. Of these patients, 65.5% (55) had the device implanted within 30 days of transplantation, and 34.5% (29) had late implantation. The mean survival of patients who had an early pacemaker implant was 6.4 years compared to 7.7 years for those with a late pacemaker implant (Ptransplantation had a pretransplant diagnosis of ischemic cardiomyopathy. In our cohort, the need for a permanent pacemaker was also associated with older

  10. Risk factors for lead complications in cardiac pacing

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nøhr, Ellen Aagaard;

    2011-01-01

    Lead complications are the main reason for reoperation after implantation of pacemakers (PM) or cardiac resynchronization therapy (CRT-P) devices.......Lead complications are the main reason for reoperation after implantation of pacemakers (PM) or cardiac resynchronization therapy (CRT-P) devices....

  11. Pacemaker patients' perception of unsafe activities: a survey

    Directory of Open Access Journals (Sweden)

    Shafquat Azam

    2008-11-01

    Full Text Available Abstract Background Cardiac pacing is a recognized and widely used treatment for patients presenting with bradycardia. Physicians expect patients to return to normal activities almost immediately post implantation. However, patients themselves may perceive interference to pacemaker function by various routine activities and devices, and hence continue to lead restricted, disabled lives. The aim of this study is to determine if routine activities are perceived by pacemaker patients to interfere with their device function. Methods A descriptive cross sectional survey was carried out on consecutive patients at the pacemaker clinic at a public hospital in Karachi, Pakistan. A 47-question tool was developed and tested. Patients' perceptions of safety of performing various routine activities, along with socio-demographic data were recorded. Results The final sample included 93 adult patients (45% males. 41% were illiterate. 77.4% recalled receiving counselling at implantation, predominantly from the implanting physician and house staff. A considerable proportion of patients considered many routine activities unsafe including driving automobiles (28%, passing through metal detectors (31%, bending over (37%, and sleeping on the side of the pacemaker (30%. Also considered unsafe were operation of household appliances- TV/VCR (television/video cassette recorders (53%, irons (55% and electrical wall switches (56%. For nearly all variables neither literacy nor history of counselling improved incorrect perceptions. Conclusion This study shows that our pacemaker patients perceive many routine activities as unsafe, potentially leading to disabling life style modifications. The tremendous investment in pacemaker technology to improve patient performance is not going to pay dividends if patients continue to remain disabled due to incorrect perceptions. Further studies are required to determine the reasons for these misperceptions, and to determine if these

  12. Perfil clínico de pacientes chagásicos e não-chagásicos portadores de marca-passo cardíaco artificial Clinical profile of Chagas and non-Chagas' disease patients with cardiac pacemaker

    Directory of Open Access Journals (Sweden)

    Leonor Garcia Rincon

    2006-06-01

    ventricle and the intensity of ventricular arrhythmia was observed. In conclusion, among pacemaker user patients, Chagas' disease is related to cardiac markers of worse prognosis.

  13. Application of clinical nursing pathway combined with individual case management model in permanent cardiac pacemaker implantation patients%临床护理路径结合个案管理模式在永久性起搏器植入患者中的应用

    Institute of Scientific and Technical Information of China (English)

    熊敏; 许少娜; 郭维英; 林宇洵

    2016-01-01

    Objective To investigate the effect of clinical nursing pathway combinied with individual case management model in permanent cardiac pacemaker implantation patients. Methods A total of 60 patients with perma-nent cardiac pacemaker implantation was selected and divided into an observation group and a control group, with 30 cases in each group. The observation group carried out clinical nursing pathway combined with individual case maneg-ment model, and the control group acceptted the traditional nursing model. The hospitalization days, cases of happening complications, score of disease knowledge questionnaire, patient s' satisfaction and anxiety level of the two groups were compared. Results Compared to the control group, the observation group had fewer hospitalization days and complica-tions, higher score of disease knowledge questionnaire and higher patient satisfaction level (P0. 05), but the anxiety level of observation group obviously lower than that of the control group when discharged from hospital (P0.05),出院时两组比较差异均有统计学意义(P<0.05)。结论在永久性起搏器植入患者中实施临床护理路径与个案管理相结合的模式,可以明显缩短住院天数,减少并发症,提高患者疾病知识掌握程度,提高患者满意度,减轻患者焦虑水平。

  14. National Cardiac Device Surveillance Program Database

    Data.gov (United States)

    Department of Veterans Affairs — The National Cardiac Device Surveillance Program Database supports the Eastern Pacemaker Surveillance Center (EPSC) staff in its function of monitoring some 11,000...

  15. Magnetic Resonance Imaging in a Patient with a Dual Chamber Pacemaker

    Directory of Open Access Journals (Sweden)

    Lynne Martina Millar

    2010-01-01

    Full Text Available Having a pacemaker has been seen an absolute contraindication to having an MRI scan. This has become increasingly difficult in clinical practice as insertion of pacemakers and implantable cardiac defibrillators is at an all time high. Here we outline a case where a 71-year-old male patient with a permanent pacemaker needed to have an MRI scan to ascertain the aetiology of his condition and help guide further management. Given this clinical dilemma, an emergency clinical ethics consultation was arranged. As a result the patient underwent an MRI scan safely under controlled conditions with a consultant cardiologist and radiologist present. The results of the MRI scan were then able to tailor further treatment. This case highlights that in certain conditions an MRI can be performed in patients with permanent pacemakers and outlines the role of clinical ethics committees in complex medical decision making.

  16. Pacemaking Kisspeptin Neurons

    Science.gov (United States)

    Kelly, Martin J.; Zhang, Chunguang; Qiu, Jian; Rønnekleiv, Oline K.

    2013-01-01

    Kisspeptin (Kiss1) neurons are vital for reproduction. GnRH neurons express the kisspeptin receptor, GPR 54, and kisspeptins potently stimulate the release of GnRH by depolarising and inducing sustained action potential firing in GnRH neurons. As such Kiss1 neurons may be the pre-synaptic pacemaker neurons in the hypothalamic circuitry that controls reproduction. There are at least two different populations of Kiss1 neurons: one in the rostral periventricular area (RP3V) that is stimulated by oestrogens and the other in the arcuate nucleus that is inhibited by oestrogens. How each of these Kiss1 neuronal populations participate in the regulation of the reproductive cycle is currently under intense investigation. Based on electrophysiological studies in the guinea pig and mouse, Kiss1 neurons in general are capable of generating burst firing behavior. Essentially all Kiss1 neurons, which have been studied thus far in the arcuate nucleus, express the ion channels necessary for burst firing, which include hyperpolarization-activated, cyclic nucleotide gated cation (HCN) channels and the T-type calcium (Cav3.1) channels. Under voltage clamp conditions, these channels produce distinct currents that under current clamp conditions can generate burst firing behavior. The future challenge is to identify other key channels and synaptic inputs involved in the regulation of the firing properties of Kiss1 neurons and the physiological regulation of the expression of these channels and receptors by oestrogens and other hormones. The ultimate goal is to understand how Kiss1 neurons control the different phases of GnRH neurosecretion and hence reproduction. PMID:23884368

  17. Pacemaker-associated Bacillus cereus endocarditis.

    Science.gov (United States)

    Barraud, Olivier; Hidri, Nadia; Ly, Kim; Pichon, Nicolas; Manea, Petrus; Ploy, Marie-Cécile; Garnier, Fabien

    2012-11-01

    We report the case of a pacemaker-associated Bacillus cereus endocarditis in a nonimmunocompromised patient. Antibiotic treatment was ineffective, and the pacemaker had to be removed. B. cereus was cultured from several blood samples and from the pacemaker electrodes. This case underlines the contribution of the rpoB gene for Bacillus species determination.

  18. Pregnancy in sick sinus syndrome with pacemaker - two cases.

    Science.gov (United States)

    Parveen, T; Begum, F; Akhter, N; Sharmin, F

    2013-04-01

    Sick sinus syndrome is a generalized abnormality of cardiac impulse formation that may be caused by extrinsic causes or by intrinsic disease of the sinus node making it unable to perform pace making function. It can be manifested for the first time in pregnancy. First case was diagnosed as sick sinus syndrome at 8 weeks of gestation having Mobitz type I heart block (Wenckebach block), and needed temporary pacemaker during caesarean section. Second case was diagnosed at 24 weeks of gestation having complete heart block and needed permanent pacemaker at 38 weeks of gestation due to exaggeration of the symptoms. Both the cases were dealt successfully by caesarean section under general anesthesia in close collaboration with cardiologists and anesthesiologists.

  19. Pacemaker patients’ perspective and experiences in a pacemaker outpatient clinic in relation to test intervals of the pacemaker

    DEFF Research Database (Denmark)

    Lauberg, Astrid; Hansen, Tina; Pedersen, Trine Pernille Dahl

    the pacemaker and psychological reactions. Patients with pacemakers older than 3 months lacked communication with fellowmen. Conclusion The patients express receiving competent and professional treatment when visiting the outpatient clinic, there seems to be a discrepancy between the long test intervals......In and out in 15 minutes! Shorttime nursing in an outpatient clinic Pacemaker patients’ perspective and experiences in a pacemaker outpatient clinic in relation to test intervals of the pacemaker. Background Pacemaker implantation is a highly documented treatment for patients with bradycardia...... an evident decline in quality of life regarding psychological and social aspects 6 month after the implantation in terms of cognitive function, work ability, and sexual activity. Mlynarski et al (2009) have found correlations between pacemaker implantation and anxiety and depression. Aim The aim...

  20. Effect of permanent pacemaker on mortality after transcatheter aortic valve replacement

    DEFF Research Database (Denmark)

    Engborg, Jonathan; Riechel-Sarup, Casper; Gerke, Oke;

    2017-01-01

    OBJECTIVES: Transcatheter aortic valve implantation (TAVI) is an established treatment for high-grade aortic valve stenosis in patients found unfit for open heart surgery. The method may cause cardiac conduction disorders requiring permanent pacemaker (PPM) implantation, and the long-term effect...

  1. 76 FR 47085 - Effective Date of Requirement for Premarket Approval for a Pacemaker Programmer

    Science.gov (United States)

    2011-08-04

    ... recommendation. C. Risks to Health 1. Cardiac arrhythmias or electrical shock: Excessive electrical leakage... is a device used to change noninvasively one or more of the electrical operating characteristics of a... therapy: Inadequate matching of the programmer to the pacemaker could lead to a situation where...

  2. Circadian Pacemaker – Temperature Compensation

    NARCIS (Netherlands)

    Gerkema, Menno P.; Binder, Marc D.; Hirokawa, Nobutaka; Windhorst, Uwe

    2009-01-01

    One of the defining characteristics of circadian pacemakers and indicates the independence of the speed of circadian clock processes of environmental temperature. Mechanisms involved, so far not elucidated in full detail, entail at least two processes that are similarly affected by temperature chang

  3. First Degree Pacemaker Exit Block

    Directory of Open Access Journals (Sweden)

    Johnson Francis

    2016-10-01

    Full Text Available Usually atrial and ventricular depolarizations follow soon after the pacemaker stimulus (spike on the ECG. But there can be an exit block due to fibrosis at the electrode - tissue interface at the lead tip. This can increase the delay between the spike and atrial or ventricular depolarization.

  4. Case study thoracic radiotherapy in an elderly patient with pacemaker: The issue of pacing leads

    Energy Technology Data Exchange (ETDEWEB)

    Kirova, Youlia M., E-mail: youlia.kirova@curie.net [Department of Radiation Oncology, Institut Curie, Paris (France); Menard, Jean; Chargari, Cyrus; Mazal, Alejandro [Department of Radiation Oncology, Institut Curie, Paris (France); Kirov, Krassen [Department of Anesthesiology and Reanimation, Institut Curie, Paris (France)

    2012-07-01

    To assess clinical outcome of patients with pacemaker treated with thoracic radiation therapy for T8-T9 paravertebral chloroma. A 92-year-old male patient with chloroma presenting as paravertebral painful and compressive (T8-T9) mass was referred for radiotherapy in the Department of Radiation Oncology, Institut Curie. The patient presented with cardiac dysfunction and a permanent pacemaker that had been implanted prior. The decision of Multidisciplinary Meeting was to deliver 30 Gy in 10 fractions for reducing the symptoms and controlling the tumor growth. The patient received a total dose of 30 Gy in 10 fractions using 4-field conformal radiotherapy with 20-MV photons. The dose to pacemaker was 0.1 Gy but a part of the pacing leads was in the irradiation fields. The patient was treated the first time in the presence of his radiation oncologist and an intensive care unit doctor. Moreover, the function of his pacemaker was monitored during the entire radiotherapy course. No change in pacemaker function was observed during any of the radiotherapy fractions. The radiotherapy was very well tolerated without any side effects. The function of the pacemaker was checked before and after the radiotherapy treatment by the cardiologist and no pacemaker dysfunction was observed. Although updated guidelines are needed with acceptable dose criteria for implantable cardiac devices, it is possible to treat patients with these devices and parts encroaching on the radiation field. This case report shows we were able to safely treat our patient through a multidisciplinary approach, monitoring the patient during each step of the treatment.

  5. Validation of the Netherlands pacemaker patient registry

    NARCIS (Netherlands)

    Dijk, WA; Kingma, T; Hooijschuur, CAM; Dassen, WRM; Hoorntje, JCA; van Gelder, LM

    1997-01-01

    This paper deals with the validation of the information stored in the Netherlands central pacemaker patient database. At this moment the registry database contains information on more than 70500 patients, 85000 pacemakers and 90000 leads. The validation procedures consisted of an internal consistenc

  6. Pre-ejection period by radial artery tonometry supplements echo doppler findings during biventricular pacemaker optimization

    Directory of Open Access Journals (Sweden)

    Qamruddin Salima

    2011-07-01

    Full Text Available Abstract Background Biventricular (Biv pacemaker echo optimization has been shown to improve cardiac output however is not routinely used due to its complexity. We investigated the role of a simple method involving computerized pre-ejection time (PEP assessment by radial artery tonometry in guiding Biv pacemaker optimization. Methods Blinded echo and radial artery tonometry were performed simultaneously in 37 patients, age 69.1 ± 12.8 years, left ventricular (LV ejection fraction (EF 33 ± 10%, during Biv pacemaker optimization. Effect of optimization on echo derived velocity time integral (VTI, ejection time (ET, myocardial performance index (MPI, radial artery tonometry derived PEP and echo-radial artery tonometry derived PEP/VTI and PEP/ET indices was evaluated. Results Significant improvement post optimization was achieved in LV ET (286.9 ± 37.3 to 299 ± 34.6 ms, p Conclusion An acute shortening of PEP by radial artery tonometry occurs post Biv pacemaker optimization and correlates with improvement in hemodynamics by echo Doppler and may provide a cost-efficient approach to assist with Biv pacemaker echo optimization.

  7. 临时起搏器在急性下壁心肌梗死窦性心律患者急诊 PCI 中的应用%The application of temporary cardiac pacemaker in acute inferior wall myocardial infarction patients with sinus rhythm treated by emergency percutaneous coronary intervention

    Institute of Scientific and Technical Information of China (English)

    宋鹏伟; 李娜; 生力健; 于江波; 刘丕栋

    2015-01-01

    Objective This study evaluated the safety and efficacy of preventive cardiac pacing in acute inferior wall myocardial infarction patients with sinus rhythm treated by emergency percutaneous coronary intervention ( PCI ) .Methods In all the 121 patients with acute inferior wall myocardial infarction and sinus rhythm who underwent successful emergency PCI and were given temporary cardiac pacemaker before PCI , 76 patients underwent cardiac pacing and were taken as preventive temporary cardiac pacing group , while 45 patients did not undergo cardiac pacing and were taken as the non cardiac pacing group .We observed the patients for general clinical manifestations , coronary artery pathological features and HR before PCI reperfusion and after atropine used , BP before and after the reperfusion , the occurrence of malignant ventricular arrhythmia .Results SBP and DBP after reperfusion in cardiac pacing group was significantly lower than those before reperfusion in the same group (P0.05).The percentage of dominant right coronary artery in non -cardiac pacing group was significantly lower than those in cardiac pacing group (P=0.0049).Both of the occurrence rates of reverse blood flow perfusion and the degree of increased heart rate after atropine used in the non -cardiac pacing group were higher than those in cardiac pacing group ( P <0.0001 ).Conclusion The temporary cardiac pacing has no preventive effect on hypotension and malignant ventricular arrhythmia after reperfusion in acute inferior wall myocardial infarction patients with sinus rhythm , however, temporary cardiac pacing could protect acuteinferior wall myocardial infarction patients from bradyarrhythmia during PCI , especially be applicable to the patients with non -reverse perfusion and poor response to atropine .%目的:探讨保护性临时起搏器在急性下壁心肌梗死( AIMI)窦性心律患者急诊经皮冠状动脉介入治疗( PCI)再灌注过程中应用的可行性与效果。方法

  8. 血流向量图评价心脏再同步化治疗中长期患者暂时中断起搏器前后左心室流场演变%Evaluation on left ventricular intra-cardiac flow field before and after temporary interruption of pacemaker in mid-to-long-term cardiac resynchronization therapy patients by vector flow mapping

    Institute of Scientific and Technical Information of China (English)

    叶晶晶; 纳丽莎; 刘丽文; 马斌; 沈敏; 左蕾; 高文霞; 周海燕

    2014-01-01

    目的 应用血流向量图(VFM)评价心脏再同步化治疗(CRT)中长期患者暂时中断起搏器前后左室收缩期血液流场变化特征以及心功能变化情况.方法 严格按照入选标准选择起搏器植入术后6个月以上的对CRT有反应的患者32例,分别于中断起搏器前后行超声心动图检查,依次测量左室短轴舒张末内径(LVEDD)及收缩末内径(LVESD),左室舒张末容积(LVEDV)及收缩末容积(LVESV),并计算左室射血分数(LVEF),测量左室压力最大上升速率(LVDp/Dtmax),主动脉瓣上血流速度时间积分(AV-VTI),二尖瓣反流容积(MRV)、面积(MRA).利用VFM软件采集左室内血流向量图像,启用涡流模式图,取二尖瓣关闭瞬间(MVC)、主动脉瓣开放瞬间(AVO)、主动脉血流速度达峰瞬间(APV)以及主动脉瓣关闭瞬间(AVC)四个节点,分别测量涡流的横径(DH)、纵径(DL)、流量(FV)、深度(VD),计算涡流面积(VA),计算从主动脉瓣开放到主动脉血流速度达峰时涡流流量的衰减率(FV-CR%)和面积的衰减率(VA-CR%),并观察其演变特征.结果 与起搏器关闭前比较,关闭起搏器10 min后患者的AV-VTI、LVDp/Dtmax均降低,差异均具有统计学意义(P<0.05);据VFM观测从主动脉瓣开放到主动脉血流速度达峰时左室腔FV-CR%、VA-CR%均减低,差异均具有统计学意义(P<0.01);且LVEF与VA-CR%存在正相关,起搏器关闭前后其相关系数分别为0.632(P<0.01)和0.654(P<0.01).结论 暂时中断起搏器后常规超声心动图测量参数及VFM参数均出现明显恶化.VFM技术能够客观有效地反映中断起搏器前后左室收缩期血液流场特征的改变与左室功能的变化及其相关关系,并提示远期持续CRT治疗的必要性.%Objective To evaluate left ventricular systolic function and intra-cardiac flow field before and after temporary interruption of pacemaker in mid-to-long-term cardiac resynchronization therapy patients by vector flow

  9. Estudo clínico e epidemiológico de pacientes submetidos a implante de marcapasso cardíaco artificial permanente: comparação dos portadores da doença de Chagas com os de doenças degenerativas do sistema de condução Clinical and epidemiological characteristics of patients with Chagas' disease submitted to permanent cardiac pacemaker implantation

    Directory of Open Access Journals (Sweden)

    Roberto Costa

    2004-06-01

    Full Text Available OBJETIVO: Estudar os pacientes portadores de marcapasso cardíaco artificial permanente, comparando as características clínicas e epidemiológicas dos portadores da doença de Chagas com a dos portadores de doenças degenerativas do sistema de condução. MÉTODO: Foram analisados 57.632 procedimentos cadastrados no Registro Brasileiro de Marcapassos, realizados no período de 1995 a 2003, sendo: 25.648 pacientes portadores da doença de Chagas e 31.984, de doenças degenerativas. A comparação das características dessas populações foi feita pelos testes do Qui-quadrado e t-Student com nível de significância de 5%. RESULTADOS: Houve predomínio da doença de Chagas na região Centro-Oeste, nos implantes iniciais. Nas reoperações, a população chagásica representou maioria também no Sudeste. A idade dos pacientes chagásicos foi 58,6 ± 15,3 e 59,3 ± 14,8 anos, respectivamente para implantes iniciais e reoperações, e, nos não chagásicos, 73,5 ± 12,6 e 73,7 ± 13,5. Não foi notada diferença na distribuição entre os dois sexos. Houve maior ocorrência de síncopes, pré-síncopes e bloqueio atrioventricular com QRS largo nos pacientes chagásicos e de tonturas, insuficiência cardíaca e QRS estreito nos não chagásicos. O modo de estimulação ventricular foi utilizado em 60% e 63% nos implantes iniciais e em 77% e 76% das reoperações, respectivamente para os pacientes chagásicos e não chagásicos. A depleção da bateria por desgaste normal foi o principal motivo para reoperação dos pacientes, tendo ocorrido em 76,1% e 79,6% das reoperações, respectivamente para chagásicos e não chagásicos. CONCLUSÕES: Os dados analisados demonstraram diferenças significativas nas características clínicas e demográficas das populações estudadas.OBJECTIVE: To study patients with permanent cardiac pacemakers, comparing the clinical and epidemiological characteristics of patients with Chagas' disease versus the ones with

  10. Novel insights on effect of atrioventricular programming of biventricular pacemaker in heart failure – a case series

    Directory of Open Access Journals (Sweden)

    Rafique Asim M

    2006-10-01

    Full Text Available Abstract Background Echocardiography plays an integral role in the diagnosis of congestive heart failure including measurement of left heart pressure as well as mechanical dyssynchrony. Methods In this report we describe novel therapeutic uses of echo pulsed wave Doppler in atrioventricular pacemaker optimization in patients who had either not derived significant symptomatic benefit post biventricular pacemaker implantation or deteriorated after deriving initial benefit. In these patients atrioventricular optimization showed novel findings and improved cardiac output and symptoms. Results In 3 patients with Cheyne Stokes pattern of respiration echo Doppler showed worsening of mitral regurgitation during hyperpneac phase in one patient, marked E and A fusion in another patient and exaggerated ventricular interdependence in a third patient thus highlighting mechanisms of adverse effects of Cheyne Stokes respiration in patients with heart failure. All 3 patients required a very short atrioventricular delay programming for best cardiac output. In one patient with recurrent congestive heart failure post cardiac resynchronization, mitral inflow pulse wave Doppler showed no A wave until a sensed atrioventricular delay of 190 ms was reached and showed progressive improvement in mitral inflow pattern until an atrioventricular delay of 290 ms. In 2 patients atrioventricular delay as short as 50 ms was required to allow E and A separation and prevent diastolic mitral regurgitation. All patients developed marked improvement in congestive heart failure symptoms post echo-guided biv pacemaker optimization. Conclusion These findings highlight the value of echo-guided pacemaker optimization in symptomatic patients post cardiac resynchronization treatment.

  11. Reduction of atrial fibrillation in remotely monitored pacemaker patients: results from a Chinese multicentre registry

    Institute of Scientific and Technical Information of China (English)

    CHEN Ke-ping; DAI Yan; HUA Wei; YANG Jie-fu; LI Kang; LIANG Zhao-guang; SHEN Fa-rong

    2013-01-01

    Background Many recipients of implantable cardiac electronic devices have atrial fibrillation (AF) occurrences after device implantation,even if there is no previous history of AF,and some of the episodes are asymptomatic.The purpose of this study was to evaluate trends in AF burden following early AF detection in patients treated with pacemakers equipped with automatic,daily Home Monitoring function.Methods Between February 2009 and December 2010,the registry recruited 701 pacemaker patients (628 dual-chamber,73 biventricular devices) at 97 clinical centers in China.Daily Home Monitoring data transmissions were analyzed to screen for the AF burden.In-office follow-ups were scheduled for 3 and 6 months after implantation.Upon first AF (i.e.,mode-switch) detection in a patient,screening of AF burden by Home Monitoring was extended for the next 180 days.Results At least one episode of AF was observed in 22.9% of patients with dual-chamber pacemakers and in 28.8% of patients with biventricular pacemakers.The first AF detection in a patient occurred,on average,about 2 months before scheduled follow-up visits.In both pacemaker groups,mean AF burden decreased significantly (P<0.05) over 180 days following first AF detection:from 12.0% to 2.5% in dual-chamber and from 12.2% to 0.5% in biventricular pacemaker recipients.The number of patients with an AF burden >10% per month was significantly reduced over 6 months of implantation in both dual chamber (38 patients in the first month vs.21 patients in month 6,P<0.05) and biventricular (7 patients in the first month vs.0 patient in months 4-6,P<0.05) pacemaker recipients.Conclusions Automatic,daily Home Monitoring of patients treated with cardiac pacemakers allows early detection of AF,and there is a gradual and significant decrease in AF burden.

  12. High ventricular lead impedance of a DDD pacemaker after cranial magnetic resonance imaging.

    Science.gov (United States)

    Baser, Kazim; Guray, Umit; Durukan, Mine; Demirkan, Burcu

    2012-09-01

    Management of electromagnetic interference in the form of magnetic resonance imaging (MRI) in patients with pacemakers (PMs) may be challenging. Serious consequences, especially in PM-dependent patients, may be encountered. Changes in device programming, asynchronous pacing, heating of the lead tip(s), and increased thresholds or even device dislocation may be experienced. We report of a patient with a DDD PM who underwent an emergent MRI, after which there was an increase in ventricular impedance as well as increased cardiac biomarkers.

  13. [Behaviour of some serum enzymes after permanent pacemaker implantation (author's transl)].

    Science.gov (United States)

    Cappelletti, F; Maiolino, P; Allegri, P; Barbieri, E; de Lio, U; Morlino, T; Ometto, R; Vincenzi, M

    1978-01-01

    The behaviour of some serum enzymes (CPK, LDH, alpha HBDH, SGOT) in 50 patients after permanent pacemaker implantation is outlined. Changes of each enzyme were analyzed statistically by applying Student's t test. Most significant changes are represented by the increase in CPK serum concentrations (19 cases). In 14 of them LDH isoenzymes were evaluated and in 4 patients alteration of LDH1/LDH2 ratio suggestive of cardiac "injury" were observed.

  14. SU-D-18C-06: Initial Experience with Implementing MRI Safety Guidelines for Patients with Pacemakers - Medical Physicist Perspective

    Energy Technology Data Exchange (ETDEWEB)

    James, J; Place, V; Panda, A [Mayo Clinic, Scottsdale, AZ (United States); Edmonson, H [Mayo Clinic College of Medicine, Rochester, MN (United States); Felmlee, J [Mayo Clinic, Rochester, MN (United States); Pooley, R [Mayo Clinic, Jacksonville, FL (United States)

    2014-06-01

    Purpose: Several institutions have developed MRI guidelines for patients with MR-unsafe or MR-conditional pacemakers. Here we highlight the role of a medical physicist in implementing these guidelines for non-pacemaker dependent patients. Guidelines: Implementing these guidelines requires involvement from several medical specialties and a strong collaboration with the site MRI supervisor to develop a structured workflow. A medical physicist is required to be present during the scan to supervise the MR scanning and to maintain a safety checklist that ensures: 1) uninterrupted patient communication with the technologist, 2) continuous patient physiologic monitoring (e.g. blood pressure and electrocardiography) by a trained nurse, 3) redundant patient vitals monitoring (e.g. pulse oximetry) due to the possibility of in vivo electrocardiography reading fluctuations during image acquisition. A radiologist is strongly recommended to be available to review the images before patients are discharged from the scanner. Pacemaker MRI should be restricted to 1.5T field strength. The MRI sequences should be optimized by the physicist with regards to: a) SAR: limited to <1.5 W/Kg for MR-unsafe pacemakers in normal operating mode, b) RF exposure time: <30 min, c) Coils: use T/R coils but not restricted to such, d) Artifacts: further optimization of sequences whenever image quality is compromised due to the pacemaker. In particular, cardiac, breast and left-shoulder MRIs are most susceptible to these artifacts. Possible strategies to lower the SAR include: a) BW reduction, 2) echo-train-length reduction, 3) increase TR, 4) decrease number of averages, 5) decrease flip angle, 6) reduce slices and/or a combination of all the options. Conclusion: A medical physicist in collaboration with the MR supervisor plays an important role in the supervision/implementation of safe MR scanning of pacemaker patients. Developing and establishing a workflow has enabled our institution to scan over

  15. [Permanent cardiac stimulation in a patient with isolated dextrocardia and ventricular septal defect].

    Science.gov (United States)

    Słowiński, S; Derlaga, B; Kapusta, J

    A case of pacemaker implantation because of acquired atrioventricular block third degree in woman aged 39 years with rare isolated dextrocardia with inversion of cardiac ventricles, compensatory transposition of both aorta and pulmonary artery, and ventricular septal defect. The end of electrode has wedged in the apex of the arterial ventricle. Following pacemaker implantation, patients clinical course of gynaecological operation was uneventful.

  16. Normal heart rhythm is initiated and regulated by an intracellular calcium clock within pacemaker cells.

    Science.gov (United States)

    Maltsev, Victor A; Lakatta, Edward G

    2007-10-01

    For almost half a century it has been thought that the heart rhythm originates on the surface membrane of the cardiac pacemaker cells and is driven by voltage-gated ion channels (membrane clocks). Data from several recent studies, however, conclusively show that the rhythm is initiated, sustained, and regulated by oscillatory Ca(2+) releases (Ca(2+) clock) from the sarcoplasmic reticulum, a major Ca(2+) store within sinoatrial node cells, the primary heart's pacemakers. Activation of the local oscillatory Ca(2+) releases is independent of membrane depolarisation and driven by a high level of basal state phosphorylation of Ca(2+) cycling proteins. The releases produce Ca(2+) wavelets under the cell surface membrane during the later phase of diastolic depolarisation and activate the forward mode of Na(+)/Ca(2+) exchanger resulting in inward membrane current, which ignites an action potential. Phosphorylation-dependent gradation of speed at which Ca(2+) clock cycles is the essential regulatory mechanism of normal pacemaker rate and rhythm. The robust regulation of pacemaker function is insured by tight integration of Ca(2+) and membrane clocks: the action potential shape and ion fluxes are tuned by membrane clocks to sustain operation of the Ca(2+) clock which produces timely and powerful ignition of the membrane clocks to effect action potentials.

  17. Position paper for management of elderly patients with pacemakers and implantable cardiac defibrillators Groupe de rythmologie et stimulation cardiaque de la Société française de cardiologie et Société française de gériatrie et gérontologie.

    Science.gov (United States)

    Fauchier, Laurent; Alonso, Christine; Anselme, Frédéric; Blangy, Hugues; Bordachar, Pierre; Boveda, Serge; Clementy, Nicolas; Defaye, Pascal; Deharo, Jean-Claude; Friocourt, Patrick; Gras, Daniel; Halimi, Franck; Klug, Didier; Mansourati, Jacques; Obadia, Benjamin; Pasquié, Jean-Luc; Pavin, Dominique; Sadoul, Nicolas; Taieb, Jérôme; Piot, Olivier; Hanon, Olivier

    2016-09-01

    Despite the increasingly high rate of implantation of pacemakers (PM) and cardioverter-defibrillators (ICD) in elderly patients, data supporting their clinical and cost-effectiveness in this age stratum are ambiguous and contradictory. We reviewed the data regarding the applicability, safety, and effectiveness of the conventional pacing, ICD and cardiac resynchronization therapy (CRT) in elderly patients. Although peri-procedural risk may be slightly higher in the elderly, the procedure of implantation of PMs and ICDs is still relatively safe in this age group. In older patients with sinus node disease, a general consensus is that dual chamber pacing, along with the programming of an algorithm to minimise ventricular pacing is preferred. In very old patients presenting with intermittent or suspected AV block, VVI pacing may be appropriate. In terms of correcting potentially life-threatening arrhythmias, the effectiveness of ICD therapy is comparable in older and younger individuals. However, the assumption of persistent ICD benefit in the elderly population is questionable, as any advantage of the device on arrhythmic death may be attenuated by a higher total non-arrhythmic mortality. While septuagenarians and octogenarians have higher annual all-cause mortality rates, ICD therapy may remain effective in selected patients at high risk of arrhythmic death and with minimum comorbidities despite advanced age. ICD implantation among the elderly, as a group, may not be cost-effective, but the procedure may reach cost-effectiveness in those expected to live >5-7 years after implantation. The elderly patients usually experience a significant functional improvement after CRT, similar to that observed in middle-aged patients. Management of CRT non responders remains globally the same, while considering a less aggressive approach in terms of re interventions (revision of LV lead placement, addition of a RV or LV lead, LV endocardial pacing configuration). Overall, age

  18. Position paper for management of elderly patients with pacemakers and implantable cardiac defibrillators: Groupe de Rythmologie et Stimulation Cardiaque de la Société Française de Cardiologie and Société Française de Gériatrie et Gérontologie.

    Science.gov (United States)

    Fauchier, Laurent; Alonso, Christine; Anselme, Frederic; Blangy, Hugues; Bordachar, Pierre; Boveda, Serge; Clementy, Nicolas; Defaye, Pascal; Deharo, Jean-Claude; Friocourt, Patrick; Gras, Daniel; Halimi, Franck; Klug, Didier; Mansourati, Jacques; Obadia, Benjamin; Pasquié, Jean-Luc; Pavin, Dominique; Sadoul, Nicolas; Taieb, Jerome; Piot, Olivier; Hanon, Olivier

    2016-10-01

    Despite the increasingly high rate of implantation of pacemakers (PMs) and implantable cardioverter defibrillators (ICDs) in elderly patients, data supporting their clinical and cost-effectiveness in this age stratum are ambiguous and contradictory. We reviewed the data regarding the applicability, safety and effectiveness of conventional pacing, ICDs and cardiac resynchronization therapy (CRT) in elderly patients. Although periprocedural risk may be slightly higher in the elderly, the implantation procedure for PMs and ICDs is still relatively safe in this age group. In older patients with sinus node disease, the general consensus is that DDD pacing with the programming of an algorithm to minimize ventricular pacing is preferred. In very old patients presenting with intermittent or suspected atrioventricular block, VVI pacing may be appropriate. In terms of correcting potentially life-threatening arrhythmias, the effectiveness of ICD therapy is similar in older and younger individuals. However, the assumption of persistent ICD benefit in the elderly population is questionable, as any advantageous effect of the device on arrhythmic death may be attenuated by higher total non-arrhythmic mortality. While septuagenarians and octogenarians have higher annual all-cause mortality rates, ICD therapy may remain effective in selected patients at high risk of arrhythmic death and with minimum comorbidities despite advanced age. ICD implantation among the elderly, as a group, may not be cost-effective, but the procedure may reach cost-effectiveness in those expected to live more than 5-7years after implantation. Elderly patients usually experience significant functional improvement after CRT, similar to that observed in middle-aged patients. Management of CRT non-responders remains globally the same, while considering a less aggressive approach in terms of reinterventions (revision of left ventricular [LV] lead placement, addition of a right ventricular or LV lead, LV

  19. Implantable defibrillators improve survival in patients with mildly symptomatic heart failure receiving cardiac resynchronization therapy

    DEFF Research Database (Denmark)

    Gold, Michael R; Daubert, Jean-Claude; Abraham, William T;

    2013-01-01

    Cardiac resynchronization therapy (CRT) decreases mortality, improves functional status, and induces reverse left ventricular remodeling in selected populations with heart failure. These benefits have been noted with both CRT-pacemakers as well as those devices with defibrillator backup (CRT...

  20. Low frequency magnetic emissions and resulting induced voltages in a pacemaker by iPod portable music players

    Directory of Open Access Journals (Sweden)

    Bassen Howard

    2008-02-01

    Full Text Available Abstract Background Recently, malfunctioning of a cardiac pacemaker electromagnetic, caused by electromagnetic interference (EMI by fields emitted by personal portable music players was highly publicized around the world. A clinical study of one patient was performed and two types of interference were observed when the clinicians placed a pacemaker programming head and an iPod were placed adjacent to the patient's implanted pacemaker. The authors concluded that "Warning labels may be needed to avoid close contact between pacemakers and iPods". We performed an in-vitro study to evaluate these claims of EMI and present our findings of no-effects" in this paper. Methods We performed in-vitro evaluations of the low frequency magnetic field emissions from various models of the Apple Inc. iPod music player. We measured magnetic field emissions with a 3-coil sensor (diameter of 3.5 cm placed within 1 cm of the surface of the player. Highly localized fields were observed (only existing in a one square cm area. We also measured the voltages induced inside an 'instrumented-can' pacemaker with two standard unipolar leads. Each iPod was placed in the air, 2.7 cm above the pacemaker case. The pacemaker case and leads were placed in a saline filled torso simulator per pacemaker electromagnetic compatibility standard ANSI/AAMI PC69:2000. Voltages inside the can were measured. Results Emissions were strongest (≈ 0.2 μT pp near a few localized points on the cases of the two iPods with hard drives. Emissions consisted of 100 kHz sinusoidal signal with lower frequency (20 msec wide pulsed amplitude modulation. Voltages induced in the iPods were below the noise level of our instruments (0.5 mV pp in the 0 – 1 kHz band or 2 mV pp in the 0 – 5 MHz bandwidth. Conclusion Our measurements of the magnitude and the spatial distribution of low frequency magnetic flux density emissions by 4 different models of iPod portable music players. Levels of less than 0.2

  1. Synchronization of Coupled Neurons Controlled by a Pacemaker

    Institute of Scientific and Technical Information of China (English)

    LI Mei-Sheng; ZHANG Hong-Hui; ZHAO Yong; SHI Xia

    2011-01-01

    We investigate synchronization of Hindmarsh-Rose neurons with gap junctions under the control of a pacemaker. In a ring Hindmarsh-Rose neuronal network, the coupled neurons with the pacemaker can occur in synchronization more easily than those without the pacemaker. Furthermore, the pacemaker can induce phase synchronization or nearly-complete synchronization of nonidentical neurons. This synchronization can occur more easily when time delay is considered. Theses results can be helpful to understand the activities of the real neuronal system.

  2. Effects of Long-term Right Ventricular Apical Pacing on Left Ventricular Remodeling and Cardiac Function

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Objective: To investigate the impacts of long-term right ventricular apical pacing on the ventricular remodeling and cardiac functions of patients with high-grade and third-degree atrioventricular blockage with normal heart structures and cardiac functions. In addition, we provide many evidences for choosing an optimal electrode implantation site.Methods: Study participants included patients who were admitted for pacemaker replacements and revisited for examinations of implanted pacemakers at outpatient. Pa...

  3. Contact dermatitis after implantable cardiac defibrillator implantation for ventricular tachycardia.

    Science.gov (United States)

    Dogan, Pinar; Inci, Sinan; Kuyumcu, Mevlut Serdar; Kus, Ozgur

    2016-02-01

    Pacemaker contact sensitivity is a rare condition. Less than 30 reports of pacemaker skin reactions have been described. We report a 57-year-old woman who underwent an implantable cardiac defibrillator (ICD) implantation for ventricular tachycardia. A skin patch test was positive on almost all components of the pacemaker system. She was treated with topical corticosteroids and skin lesions resolved within 2 weeks. Because of widespread use of various devices, we will see this more often and therefore it is important to recognize this problem and its effective management.

  4. The effectiveness of rigid pericardial endoscopy for minimally invasive minor surgeries: cell transplantation, epicardial pacemaker lead implantation, and epicardial ablation

    Directory of Open Access Journals (Sweden)

    Kimura Takehiro

    2012-11-01

    Full Text Available Abstract Background The efficacy and safety of rigid pericardial endoscopy as the promising minimally invasive approach to the pericardial space was evaluated. Techniques for cell transplantation, epicardial pacemaker lead implantation, and epicardial ablation were developed. Methods Two swine and 5 canines were studied to evaluate the safety and efficacy of rigid pericardial endoscopy. After a double pericardiocentesis, a transurethral rigid endoscope was inserted into the pericardial space. The technique to obtain a clear visual field was examined, and acute complications such as hemodynamic changes and the effects on intra-pericardial pressure were evaluated. Using custom-made needles, pacemaker leads, and forceps, the applications for cell transplantation, epicardial pacemaker lead implantation, and epicardial ablation were also evaluated. Results The use of air, the detention of a stiff guide wire in the pericardial space, and the stretching of the pericardium with the rigid endoscope were all useful to obtain a clear visual field. A side-lying position also aided observation of the posterior side of the heart. As a cell transplantation methodology, we developed an ultrasonography-guided needle, which allows for the safe visualization of transplantation without major complications. Pacemaker leads were safely and properly implanted, which provides a better outcome for cardiac resynchronizing therapy. Furthermore, the success of clear visualization of the pulmonary veins enabled us to perform epicardial ablation. Conclusions Rigid pericardial endoscopy holds promise as a safe method for minimally invasive cell transplantation, epicardial pacemaker lead implantation, and epicardial ablation by allowing clear visualization of the pericardial space.

  5. 21 CFR 870.1750 - External programmable pacemaker pulse generator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External programmable pacemaker pulse generator... External programmable pacemaker pulse generator. (a) Identification. An external programmable pacemaker pulse generators is a device that can be programmed to produce one or more pulses at...

  6. 21 CFR 870.3610 - Implantable pacemaker pulse generator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Implantable pacemaker pulse generator. 870.3610... pacemaker pulse generator. (a) Identification. An implantable pacemaker pulse generator is a device that has a power supply and electronic circuits that produce a periodic electrical pulse to stimulate...

  7. 21 CFR 870.3600 - External pacemaker pulse generator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External pacemaker pulse generator. 870.3600... pacemaker pulse generator. (a) Identification. An external pacemaker pulse generator is a device that has a power supply and electronic circuits that produce a periodic electrical pulse to stimulate the...

  8. Cardiac Arrhythmias: Diagnosis, Symptoms, and Treatments.

    Science.gov (United States)

    Fu, Du-Guan

    2015-11-01

    The cardiac arrhythmia is characterized by irregular rhythm of heartbeat which could be either too slow (100 beats/min) and can happen at any age. The use of pacemaker and defibrillators devices has been suggested for heart arrhythmias patients. The antiarrhythmic medications have been reported for the treatment of cardiac arrhythmias or irregular heartbeats. The diagnosis, symptoms, and treatments of cardiac arrhythmias as well as the radiofrequency ablation, tachycardia, Brugada syndrome, arterial fibrillation, and recent research on the genetics of cardiac arrhythmias have been described here.

  9. Entirely polytetrafluoroethylene coating for pacemaker system contact dermatitis.

    Science.gov (United States)

    Tamenishi, Akinori; Usui, Akihiko; Oshima, Hideki; Ueda, Yuichi

    2008-04-01

    A 63-year-old man underwent pacemaker implantation for complete atrio-ventricular block. The patient repeated admissions for skin necrosis, and generator or pacemaker system was re-implanted each time. The patient was admitted with skin necrosis of the generator pocket three years after re-implantation. A skin patch test was positive on almost all components of the pacemaker system. The patient underwent pacemaker system removal and re-implantation of polytetrafluoroethylene (PTFE) sheets coating pericardium leads and generator. There has been no recurrence. PTFE sheet coating is effective to treat pacemaker system contact dermatitis.

  10. Runaway pacemaker: a still existing complication and therapeutic guidelines

    DEFF Research Database (Denmark)

    Mickley, H; Andersen, C; Nielsen, L H

    1989-01-01

    Runaway pacemaker is a rare, but still existing potential lethal complication in permanent pacemakers. Within 4 1/2 years, we saw two cases of runaway pacemaker in patients with multiprogrammable, VVI pacemakers (Siemens-Elema, Model 668). In both cases a pacemaker-induced ventricular tachycardia...... (rate 240-260 beats/min) was documented. One patient died. Runaway pacemakers must be exchanged as soon as possible. Until this can be accomplished, different emergency maneuvers should be tried. As documented in the cases presented, placing a magnet over the pacemaker may result in a lower, more...... physiological pacing rate. Reprogramming the pulse generator to a lower output or the use of external chest wall overdrive stimulation may also be successful, but these procedures require the presence of an adequate escape rhythm. If this is not the case or the former maneuvers have failed, an external...

  11. Low atrial septum pacing in pacemaker patients

    NARCIS (Netherlands)

    Voogt, Willem Gijsbert de

    2006-01-01

    In patients with an indication for anti bradycardia pacing, atrial fibrillation (AF) is a common arrhythmia (30-50%) even in the absence of atrial tachy arrhythmias before pacemaker implantation. Pace prevention and pace intervention for atrial tachy arrhythmias could be an interesting adjuvant trea

  12. Does bipolar pacemaker current activate blood platelets?

    DEFF Research Database (Denmark)

    Gjesdal, Grunde; Hansen, Annebirthe Bo; Brandes, Axel

    2009-01-01

    to the pacemaker can. METHODS: Platelet-rich plasma was prepared from two healthy subjects. Platelet reactivity to the agonist ADP was tested in paired samples in an aggregometer in a case/control setup. RESULTS: Eighteen of 46 tested pairs of platelet-rich plasma showed increased reactivity in the paced sample...

  13. Prevention of pacemaker-associated contact dermatitis by polytetrafluoroethylene sheet and conduit coating of the pacemaker system.

    Science.gov (United States)

    Taguchi, Takahiro; Maeba, Satoru; Sueda, Taijiro

    2014-09-01

    A 73-year-old female with sick sinus syndrome and atrial fibrillation was implanted with a ventricular demand inhibit pacemaker. She subsequently developed multiple episodes of skin irritation and necrosis. Skin patch testing revealed sensitivity to almost every component of the pacemaker system. The pacemaker was removed and replaced with a new pacemaker in which the generator was covered with a polytetrafluoroethylene (PTFE) sheet and the lead was covered with PTFE conduit. The patient suffered no further episodes of pacemaker-associated contact dermatitis.

  14. Recalls of cardiac implants in the last decade: what lessons can we learn?

    Directory of Open Access Journals (Sweden)

    Shixuan Zhang

    Full Text Available Due to an ageing population and demographic changes worldwide, a higher prevalence of heart disease is forecasted, which causes an even higher demand for cardiac implants in future. The increasing high incidence of clinical adverse events attributed especially to high-risk medical devices has led an advocated change from many stakeholders. This holds especially true for devices like cardiac implants, with their high-risk nature and high complication rates associated with considerable mortality, due to their frequent use in older populations with frequent co-morbidities. To ensure patients' safety, the objective of this study is to analyze different cardiac implants recall reasons and different recall systems, based on an overview of the recalls of cardiac implant medical devices in the last decade. On the basis of the results from this structured analysis, this study provides recommendations on how to avoid such recalls from a manufacturer perspective, as well as how to timely react to an adverse event from a post-surveillance system perspective.A systematic search of cardiac implant recalls information has been performed in the PubMed, ScienceDirect and Scopus databases, as well as data sources in regulatory authorities from 193 UN Member States. Data has been extracted for the years 2004-2014 with the following criteria applied: cardiac implant medical device recalls and reasons for recall, associated harm or risk to patients. From the data sources described above, eleven regulatory authorities and 103 recall reports have been included in this study. The largest cardiac implant categories include ICDs 40.8%, pacemakers 14.5% and stents 14.5%. Regarding the recall reasons, the majority of reports were related to device battery problems (33.0% and incorrect therapy delivery (31.1%. From a total of 103 recall reports, five reported death and serious injuries. Our review highlights weaknesses in the current cardiac implant recall system, including

  15. Case report: use caution when applying magnets to pacemakers or defibrillators for surgery.

    Science.gov (United States)

    Schulman, Peter M; Rozner, Marc A

    2013-08-01

    The application of a magnet to a pacemaker (intended to cause asynchronous pacing) or implanted cardioverter defibrillator (intended to prevent shocks) during surgery without a clear understanding of actual magnet function(s) or precautions can have unexpected, untoward, or harmful consequences. In this report, we present 3 cases in which inadequate assessment of cardiac implanted electronic device (CIED) function, coupled with magnet application, contributed to or resulted in inappropriate antitachycardia pacing or shocks, CIED damage, or patient injury. Although these cases might be rare, they reinforce the need for a timely, detailed preoperative review of CIED function and programming as recommended by the American Society of Anesthesiologists and the Heart Rhythm Society.

  16. Spontaneous electrical activity of guinea-pig sinoatrial cells under modulation of two different pacemaker mechanisms

    Directory of Open Access Journals (Sweden)

    Francesca Cacciani

    2014-01-01

    Full Text Available The main cellular determinants of cardiac automaticity are the hyperpolarization-activated cationic current If, and the electrogenic Na+/Ca2+ exchanger which generates an inward current after each action potential (AP. Our goal was to evaluate their relative role in pacemaking, by means of application of Ivabradine (IVA (specific If blocker and Ryanodine (RYA (known to abolish calcium transient on enzimatically isolated guinea-pig pacemaker cells. Spontaneous APs were recorded in patch-clamp whole cell configuration at 36°C from 7 cells perfused with the following sequence of solutions: physiological normal tyrode (NT, IVA 3 mM, NT and RYA 3 mM. Cycle length (CL, ms and diastolic depolarization rate (DDR, V/s were also calculated. Both blockers displayed similar effects, increasing CL (by 27 and 30%, respectively, and decreasing DDR (by 34 and 42% with respect to NT exposure. These results suggest that both mechanisms are involved into pacemaking mechanism at a similar degree.

  17. Influence of D-net (European GSM-Standard) cellular phones on pacemaker function in 50 patients with permanent pacemakers.

    Science.gov (United States)

    Wilke, A; Grimm, W; Funck, R; Maisch, B

    1996-10-01

    The widespread use of cellular phones in the last years has prompted some recent studies to suggest an interference of pacemaker function by cellular phone usage. To determine the risk of pacemaker patients using D-net cellular phones, we tested 50 patients with permanent pacemakers after routine pacemaker check by short phone calls using a cellular phone (Ericsson, D-net, frequency 890-915 MHz, digital information coding, equivalent to the European Groupe Systemes Mobiles standard). A six-channel surface ECG was continuously recorded from each patient to detect any interactions between pacemakers and cellular phones. Phone calls were repeated during the following pacemaker settings: (1) preexisting setting; (2) minimum ventricular rate of 90 beats/min and preexisting sensitivity; and (3) minimum ventricular rate of 90 beats/min and maximum sensitivity without T wave oversensing. Only 2 (4%) of 50 patients repeatedly showed intermittent pacemaker inhibition during calls with the cellular phone. Both pacemakers had unipolar sensing. Therefore, although interactions between cellular phone use and pacemaker function appear to be rare in our study, pacemaker dependent patients in particular should avoid the use of cellular phones.

  18. Choosing the pacemaker; a rational approach to the use of modern pacemaker technology.

    Science.gov (United States)

    Morgan, J M; Joseph, S P; Bahri, A K; Ramdial, J; Crowther, A

    1990-08-01

    Sophisticated pacemakers now afford greater benefit than only relief of syncope for patients with symptomatic bradyarrhythmia. For clinical reasons it is inappropriate to implant ventricular demand (VVI) pacemakers in every patient, but for both clinical and economic reasons it is also undesirable to use dual-lead or rate-responsive systems indiscriminately. However, the published guidelines for pacemaker choice and investigation are inadequate. We have analysed the clinical assessment and the investigations required in a series of 150 patients with various electrophysiological disorders, considered consecutively for pacemaker implantation using an algorithm to assist decisions. Holter electrocardiography in 77.3%, exercise testing--formal (in 9.3%) or informal (during Holter electrocardiography), electrophysiology study (EPS)--full in 15.3% and partial in 29.3%, and trial of pacing (10.7%) were all used to characterize dysfunction and to define appropriate pacing mode. 142 patients were paced--57.0% with single lead modes (12.7%) AAI, 44.3% VVI) and 43.0% dual-lead (2.8% DVI, 23.9% VDD or VAT, 16.2% DDD). Three patients received rate-responsive systems (VVIR) which, if available, would have been used in nine; four would have been suitable for AAIR and four for dual-lead responsive pacing (DVIR, DDIR or DDDR). We offer a rational approach based on published data for investigation and pacemaker choice in the management of patients with bradyarrhythmia.

  19. [Magnets, pacemaker and defibrillator: fatal attraction?].

    Science.gov (United States)

    Bergamin, C; Graf, D

    2015-05-27

    This article aims at clarifying the effects of a clinical magnet on pacemakers and Implantable Cardioverter Defibrillators. The effects of electromagnetic interferences on such devices, including interferences linked to electrosurgery and magnetic resonance imaging are also discussed. In general, a magnet provokes a distinctive effect on a pacemaker by converting it into an asynchronous mode of pacing, and on an Implantable Cardioverter Defibrillator by suspending its own antitachyarythmia therapies without affecting the pacing. In the operating room, the magnet has to be used cautiously with precisely defined protocols which respect the type of the device used, the type of intervention planned, the presence or absence of EMI and the pacing-dependency of the patient.

  20. Neutron absorbed dose in a pacemaker CMOS

    Energy Technology Data Exchange (ETDEWEB)

    Borja H, C. G.; Guzman G, K. A.; Valero L, C.; Banuelos F, A.; Hernandez D, V. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Paredes G, L., E-mail: fermineutron@yahoo.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2012-06-15

    The neutron spectrum and the absorbed dose in a Complementary Metal Oxide Semiconductor (CMOS), has been estimated using Monte Carlo methods. Eventually a person with a pacemaker becomes an oncology patient that must be treated in a linear accelerator. Pacemaker has integrated circuits as CMOS that are sensitive to intense and pulsed radiation fields. Above 7 MV therapeutic beam is contaminated with photoneutrons that could damage the CMOS. Here, the neutron spectrum and the absorbed dose in a CMOS cell was calculated, also the spectra were calculated in two point-like detectors in the room. Neutron spectrum in the CMOS cell shows a small peak between 0.1 to 1 MeV and a larger peak in the thermal region, joined by epithermal neutrons, same features were observed in the point-like detectors. The absorbed dose in the CMOS was 1.522 x 10{sup -17} Gy per neutron emitted by the source. (Author)

  1. Ischemic Stroke Due to Cardiac Involvement: Emery Dreifuss Patient

    Directory of Open Access Journals (Sweden)

    Ersin Kasım Ulusoy

    2015-08-01

    Full Text Available Emery-Dreifuss muscular dystrophy (EDMD is a hereditary disease. It is characterized by early-onset contractures, slowly progressive weakness, fatigue related to skapulo-humero-peroneal muscle weakness, cardiomyopathy which develops in adulthood and cardiac conduction system block. Cardiac involvement has a prognostic significance in patients with EDMD and even sudden cardiac death may be the first clinical presentation. In this article, an EDMD patient with ischemic stroke clinic who didn’t have regular cardiac follow-up was reported and the importance of the treatment of cardiac diseases which could play a role in ischemic stroke etiology and the implantation of pace-maker was mentioned.

  2. Pneumothorax in cardiac pacing

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard;

    2012-01-01

    AIM: To identify risk factors for pneumothorax treated with a chest tube after cardiac pacing device implantation in a population-based cohort.METHODS AND RESULTS: A nationwide cohort study was performed based on data on 28 860 patients from the Danish Pacemaker Register, which included all Danish...... patients who received their first pacemaker (PM) or cardiac resynchronization device from 1997 to 2008. Multiple logistic regression was used to estimate adjusted odds ratios (aOR) with 95% confidence intervals for the association between risk factors and pneumothorax treated with a chest tube. The median...... age was 77 years (25th and 75th percentile: 69-84) and 55% were male (n = 15 785). A total of 190 patients (0.66%) were treated for pneumothorax, which was more often in women [aOR 1.9 (1.4-2.6)], and in patients with age >80 years [aOR 1.4 (1.0-1.9)], a prior history of chronic obstructive pulmonary...

  3. Abnormal musical pacemaker in a patient with musical hallucinations.

    Science.gov (United States)

    Biran, I; Steiner, I

    2006-12-01

    Music creation requires a highly orchestrated temporal pattern. The study of a patient with repetitive musical hallucinations enabled us to examine temporal pacemakers in music production. Here, we show that the pattern of faster silent production of a chosen tune compared with its production aloud was reversed when the patient produced the hallucinatory tune. This observation might suggest the utilization of a pacemaker(s), which functions differentially during the disease.

  4. The effect of metal detector gates on implanted permanent pacemakers.

    Science.gov (United States)

    Copperman, Y; Zarfati, D; Laniado, S

    1988-10-01

    The effect of metal detector security gates, such as are used in airports, was tested in 103 nonselected pacemaker patients. Various types of single and dual chamber units were examined, using telemetry during the test. Pulse rate and duration were measured immediately before and after the procedure. No ill effect was seen on any of the units tested, pacemaker inhibition was not observed, and programmability was not affected. Metal detector security gates have no effect on implanted permanent pacemakers.

  5. A rare case of recurrent pacemaker allergic reaction

    Directory of Open Access Journals (Sweden)

    Muhammed Shittu

    2015-01-01

    Full Text Available Allergic reactions to pacemaker device components are uncommon. However, when they occur, they usually mimic pacemaker infection, which results in multiple device replacements and increased morbidity burden. Here we present a 40-year-old female with pacemaker insertion due to complete heart block and who had multiple device replacements because of allergic sensitivity to various pacemaker component-encasing materials, confirmed by allergic testing to these materials. She had complete resolution of her symptoms after replacement with gold-plated device, to which she was not allergic.

  6. Button batteries

    Science.gov (United States)

    Swallowing batteries ... These devices use button batteries: Calculators Cameras Hearing aids Penlights Watches ... If a person puts the battery up their nose and breathes it further in, ... problems Cough Pneumonia (if the battery goes unnoticed) ...

  7. Quantification of fiber orientation in the canine atrial pacemaker complex using optical coherence tomography

    Science.gov (United States)

    Ambrosi, Christina M.; Fedorov, Vadim V.; Schuessler, Richard B.; Rollins, Andrew M.

    2012-01-01

    Abstract The atrial pacemaker complex is responsible for the initiation and early propagation of cardiac impulses. Optical coherence tomography (OCT), a nondestructive imaging modality with spatial resolutions of ∼1 to 15 μm, can be used to identify unique fiber orientation patterns in this region of the heart. Functionally characterized canine sinoatrial nodes (SAN) (n=7) were imaged using OCT up to ∼1  mm below the endocardial tissue surface. OCT images were directly compared to their corresponding histological sections. Fiber orientation patterns unique to the crista terminalis (CT), SAN, and surrounding atrial myocardium were identified with dominant average fiber angles of 89±12  deg, 110±16  deg, and 95±35  deg, respectively. Both the CT and surrounding atrial myocardium displayed predominantly unidirectionally based fiber orientation patterns within each specimen, whereas the SAN displayed an increased amount of fiber disarray manifested quantitatively as a significantly greater standard deviation in fiber angle distribution within specimens [33±7  deg versus 23±5  deg, atrium (p=0.02); 18±3  deg, CT (p=0.0003)]. We also identified unique, local patterns of fiber orientation specific to the functionally characterized block zone. We demonstrate the ability of OCT in detecting components of the atrial pacemaker complex which are intimately involved in both normal and abnormal cardiac conduction. PMID:22894470

  8. Direct and reflex cardiac bradydysrhythmias from small vagal nerve stiumaltions.

    Science.gov (United States)

    Hageman, G R; Randall, W C; Armour, J A

    1975-03-01

    Alterations in cardiac pacemaker location, its rate of discharge, and A-V conduction patterns were induced in anesthetized adult dogs by electrical stimulation of the thoracic vagi and their small cardiac branches before and after cervical vagotomy. Electrical activity from small, contiguous bipolar silver electrodes was amplified and recorded by an optical oscillograph. The electrodes were located over the SA node, the three internodal pathways, the left atrium, and ventricular epicardium. A hoffman-type plaque electrode was placed over the A-V node to record a His bundle electrogram simultaneously with a Lead II electrocardiogram. Electrical stimulation of the intact left recurrent laryngeal nerve and its cardiac branches before and after vagotomy induced both direct and reflex effects on SA nodal cycle length. Efferent dromotropic effects on the A-V node varied from first- to third-degree heart block during stimulation of individual left recurrent cardiac branches. Stimulation of the right recurrent cardiac nerve induced atrial bradycardia with heart block above the His bundle. Stimulation of individual right vagal branches near the heart induced bradycardia, cardiac asystole, shifts in atrial pacemaker location, or activation of His pacemakers. Establishment of the His rhythm probably indicates selective inhibition of supraventricular but not of the His bundle. Asystole and His rhythms induced during stimulation of the more caudal branches of the right cardiac vagal nerves were generally reflexly mediated and were abolished by cervical vagotomy.

  9. Dislocation of an infected and abandoned pacemaker lead.

    Science.gov (United States)

    Kostopoulou, Anna G; Kyrzopoulos, Stamatios D; Livanis, Efthimios G

    2012-11-01

    We present a case of pacemaker lead dislodgment in an 83-year-old patient with a pacemaker infection. Initially, the generator and the proximal part of the leads were removed, and the remaining leads were severed and abandoned. Twenty-five days later, dislodgment of both abandoned leads and systemic infection were documented. The leads were then surgically removed without further complications.

  10. A NEW METHOD FOR DIAGRAMMING PACEMAKER/HEART INTERACTION

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    Advancements in technology have enhanced the performance of pacemakers but made the interaction between the pacemaker and the heart becoming increasingly complex, and its is difficult to interpret the paced ECGs (PGCGs). This paper introduces a brief method to interpret PECGs, which illustrate the timing intervals graphically and avoid using symbols and strings.

  11. The Drosophila melanogaster circadian pacemaker circuit

    Indian Academy of Sciences (India)

    Vasu Sheeba

    2008-12-01

    As an experimental model system, the fruit fly Drosophila melanogaster has been seminal in shaping our understanding of the circadian clockwork. The wealth of genetic tools at our disposal over the past four decades has enabled discovery of the genetic and molecular bases of circadian rhythmicity. More recently, detailed investigation leading to the anatomical, neurochemical and electrophysiological characterization of the various neuronal subgroups that comprise the circadian machinery has revealed pathways through which these neurons come together to act as a neuronal circuit. Thus the D. melanogaster circadian pacemaker circuit presents a relatively simple and attractive model for the study of neuronal circuits and their functions.

  12. A Formal Verification Methodology for DDD Mode Pacemaker Control Programs

    Directory of Open Access Journals (Sweden)

    Sana Shuja

    2015-01-01

    Full Text Available Pacemakers are safety-critical devices whose faulty behaviors can cause harm or even death. Often these faulty behaviors are caused due to bugs in programs used for digital control of pacemakers. We present a formal verification methodology that can be used to check the correctness of object code programs that implement the safety-critical control functions of DDD mode pacemakers. Our methodology is based on the theory of Well-Founded Equivalence Bisimulation (WEB refinement, where both formal specifications and implementation are treated as transition systems. We develop a simple and general formal specification for DDD mode pacemakers. We also develop correctness proof obligations that can be applied to validate object code programs used for pacemaker control. Using our methodology, we were able to verify a control program with millions of transitions against the simple specification with only 10 transitions. Our method also found several bugs during the verification process.

  13. Pacemaker implantation complication rates in elderly and young patients

    Directory of Open Access Journals (Sweden)

    Özcan KS

    2013-08-01

    Full Text Available Kazim Serhan Özcan, Damirbek Osmonov, Servet Altay, Cevdet Dönmez, Ersin Yildirim, Ceyhan Türkkan, Baris Güngör, Ahmet Ekmekçi, Ahmet Taha Alper, Kadir Gürkan, İzzet ErdinlerDepartment of Cardiology, Siyami Ersek Cardiovascular and Thoracic Surgery Center, Istanbul, TurkeyAims: To evaluate the complication rate differences between elderly and younger patients who receive a permanent pacemaker implantation.Methods: We reviewed all cases admitted to our institution between January 2008 and June 2009 with symptomatic bradyarrhythmia for whom a permanent pacemaker was implanted. Beginning in June 2009, we prospectively collected data from all patients with the same diagnosis and procedure. The frequency of complications due to the pacemaker implantation procedure was evaluated and compared between young (<70 years old and elderly (≥70 years old patients.Results: Among 574 patients with a permanent pacemaker, 259 patients (45.1% were below and 315 patients (54.9% were above or at 70 years of age. There were 240 (92.7% and 19 (7.3% dual-chamber pacemaker (DDD and single-chamber pacemaker (VVI implanted patients in the younger group, and 291 (76.8% and 73 (23.2% DDD and VVI pacemaker implanted patients in the elderly group, respectively. The complication rate was 39 (15.1% out of 259 young patients and 24 (7.6% out of 315 elderly patients. Postprocedural complications were statistically lower in the elderly patients than in younger patients (P = 0.005.Conclusion: A pacemaker implantation performed by an experienced operator is a safe procedure for patients of advanced age. The patients who are above 70 years old may have less complication rates than the younger patients.Keywords: complications of pacemaker implantation, elderly patients, permanent pacemaker

  14. Perioperative management of patients with cardiac implantable electronic devices.

    Science.gov (United States)

    Poveda-Jaramillo, R; Castro-Arias, H D; Vallejo-Zarate, C; Ramos-Hurtado, L F

    2017-05-01

    The use of implantable cardiac devices in people of all ages is increasing, especially in the elderly population: patients with pacemakers, cardioverter-defibrillators or cardiac resynchronization therapy devices regularly present for surgery for non-cardiac causes. This review was made in order to collect and analyze the latest evidence for the proper management of implantable cardiac devices in the perioperative period. Through a detailed exploration of PubMed, Academic Search Complete (EBSCO), ClinicalKey, Cochrane (Ovid), the search software UpToDate, textbooks and patents freely available to the public on Google, we selected 33 monographs, which matched the objectives of this publication.

  15. Routine chest radiography after permanent pacemaker implantation: Is it necessary?

    Directory of Open Access Journals (Sweden)

    Edwards N

    2005-01-01

    Full Text Available Background and Aims: Chest radiographs (CXRs are performed routinely after permanent pacemaker implantation to identify pacemaker lead position and exclude pneumothorax. We assessed the clinical value and need for this procedure. Design: Retrospective analysis of pacemaker data and CXRs following permanent pacemaker insertion between December 2002 and February 2004. Materials and Methods: Post-procedural CXRs were available in 125/126 consecutive patients after either first endocardial pacemaker implantation or insertion of at least one new lead. Subclavian vein puncture was used for venous access in all cases. CXRs were examined to establish the incidence of pneumothorax and assess pacing lead positions. The clinical records were examined in all patients who had subsequent CXRs or a further pacemaker procedure to identify the indication for these and to establish whether CXR had influenced patient management. Results: In total, 192 post-procedural CXRs were performed, either postero-anterior (PA and/or lateral views. Ventricular and/or atrial pacing lead contour and electrode position was considered radiographically appropriate in 86% CXRs. Fourteen per cent of post-procedural radiographs were considered to have radiologically sub-optimal pacemaker lead positioning. None of the patients with these "abnormal" radiographs experienced subsequent pacemaker complications or had further radiographs recorded at a later date. Later repeat CXRs were performed in 16 patients (13% but only 3 patients (2% had pacing abnormalities as the primary indication. All three had satisfactory pacing lead position on initial post-implantation and later radiographs, but required further procedures for lead re-positioning. Iatrogenic pneumothorax occurred in one patient (incidence 0.8% in our series. CXR confirmed the clinical diagnosis and allowed an assessment of size to guide treatment. Conclusion: Routine CXR after permanent pacemaker insertion is not necessary in

  16. Firing Patterns and Transitions in Coupled Neurons Controlled by a Pacemaker

    Institute of Scientific and Technical Information of China (English)

    LI Mei-Sheng; LU Qi-Shao; DUAN Li-Xia; WANG Qing-Yun

    2008-01-01

    @@ To reveal the dynamics of neuronal networks with pacemakers, the firing patterns and their transitions are investigated in a ring HR neuronal network with gap junctions under the control of a pacemaker. Compared with the situation without pacemaker, the neurons in the network can exhibit various firing patterns as the external current is applied or the coupling strength of pacemaker varies. The results are beneficial for understanding the complex cooperative behaviour of large neural assemblies with pacemaker control.

  17. [Pacemaker implantation in dogs: results of the last 30 years].

    Science.gov (United States)

    François, L; Chetboul, V; Nicolle, A; Carlos, C; Borenstein, N; Pouchelon, J L

    2004-07-01

    Pacemaker implantation in veterinary practice is still not well known and remains uncommon. However, this technique is the only possible way to cure animals suffering from symptomatic bradycardia whose state does not improve with a medical treatment. In most cases, the use of pacemakers in veterinary medicine leads to the disappearance of the clinical and electrocardiographic signs. This retrospective study concerning the last 30 years draws up an evaluation of the improvements, advantages and drawbacks of this method. Moreover, this study allows the understanding of the evolution of pacemakers' use in veterinary cardiology.

  18. Isolated Cardiac Involvement in Primary Amyloidosis: Presenting as Sick Sinus Syndrome and Heart Failure

    OpenAIRE

    Pattanshetty, Deepak J.; Bhat,Pradeep K; Chamberlain, Wendy A.; Lyons, Matthew R.

    2013-01-01

    Cardiac amyloidosis is an infiltrative cardiomyopathy with a grave prognosis. Its clinical manifestations include restrictive cardiomyopathy, diastolic heart failure, conduction defects, and arrhythmias. Isolated cardiac involvement and significant conduction disturbances are reported very infrequently. We report a rare case of isolated cardiac involvement in primary amyloidosis, in a 76-year-old man who initially presented with sick sinus syndrome that necessitated permanent pacemaker insert...

  19. A review of economic evaluation models for cardiac resynchronization therapy with implantable cardioverter defibrillators in patients with heart failure

    NARCIS (Netherlands)

    Tomini, F.; van Asselt, A. D.

    2012-01-01

    OBJECTIVES: Cardiac resynchronization therapy with biventricular pacemaker (CRT-P) is considered an effective treatment for heart failure (HF). Adding implantable cardioverter defibrillators (CRT-D) may further reduce the risk of sudden cardiac death (SCD). However, economic evaluations have shown t

  20. Neutron absorbed dose in a pacemaker CMOS

    Energy Technology Data Exchange (ETDEWEB)

    Borja H, C. G.; Guzman G, K. A.; Valero L, C. Y.; Banuelos F, A.; Hernandez D, V. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Paredes G, L., E-mail: candy_borja@hotmail.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2011-11-15

    The absorbed dose due to neutrons by a Complementary Metal Oxide Semiconductor (CMOS) has been estimated using Monte Carlo methods. Eventually a person with a pacemaker becomes a patient that must be treated by radiotherapy with a linear accelerator; the pacemaker has integrated circuits as CMOS that are sensitive to intense and pulsed radiation fields. When the Linac is working in Bremsstrahlung mode an undesirable neutron field is produced due to photoneutron reactions; these neutrons could damage the CMOS putting the patient at risk during the radiotherapy treatment. In order to estimate the neutron dose in the CMOS a Monte Carlo calculation was carried out where a full radiotherapy vault room was modeled with a W-made spherical shell in whose center was located the source term of photoneutrons produced by a Linac head operating in Bremsstrahlung mode at 18 MV. In the calculations a phantom made of tissue equivalent was modeled while a beam of photoneutrons was applied on the phantom prostatic region using a field of 10 x 10 cm{sup 2}. During simulation neutrons were isotropically transported from the Linac head to the phantom chest, here a 1 {theta} x 1 cm{sup 2} cylinder made of polystyrene was modeled as the CMOS, where the neutron spectrum and the absorbed dose were estimated. Main damages to CMOS are by protons produced during neutron collisions protective cover made of H-rich materials, here the neutron spectrum that reach the CMOS was calculated showing a small peak around 0.1 MeV and a larger peak in the thermal region, both connected through epithermal neutrons. (Author)

  1. Implantation of VVI pacemaker in a patient with dextrocardia, persistent left superior vena cava, and sick sinus syndrome

    Science.gov (United States)

    Guo, Gongliang; Yang, Lili; Wu, Jinyi; Sun, Liqun

    2017-01-01

    Abstract Background: Dextrocardia, or right-lying heart, is an uncommon congenital heart disease in which the apex of the heart is located on the right side of chest. Persistent left superior vena cava (PLSVA) is a rare venous anomaly that is often associated with the abnormalities of cardiac transduction system. A case with combination of dextrocardia, persistent left superior vena cava, and sick sinus syndrome has not been reported. Methods: We used different techniques including cardiac color Doppler echocardiography, 24-hour Holter monitoring, and abdominal ultrasound to make a diagnosis and treated the patient by implanting a VVI pacemaker. Results: A 50-year-old woman was admitted with a syncope. Angiography of the right atrium and superior vena cava, echocardiography, electrocardiography, and abdominal ultrasound revealed the presence of the combination of mirror image dextrocardia, PLSVA, and sick sinus syndrome. The complex structural anomalies presented great technical challenges for interventional treatments. After thorough examination and understanding of the structural anatomy and anomalies of the superior and inferior vena cava and cardiac chambers, we successfully treated this patient by implanting a VVI pacemaker. Conclusion: Physicians must be aware of the complexity of the morphological and anatomical structures of dextrocardia accompanying PLSVC. Given that the diagnosis of situs inversus was performed at a relatively advanced age, it is therefore important to make such a correct diagnosis followed by appropriate therapeutic intervention. PMID:28151908

  2. Cardiac fluid dynamics anticipates heart adaptation.

    Science.gov (United States)

    Pedrizzetti, Gianni; Martiniello, Alfonso R; Bianchi, Valter; D'Onofrio, Antonio; Caso, Pio; Tonti, Giovanni

    2015-01-21

    Hemodynamic forces represent an epigenetic factor during heart development and are supposed to influence the pathology of the grown heart. Cardiac blood motion is characterized by a vortical dynamics, and it is common belief that the cardiac vortex has a role in disease progressions or regression. Here we provide a preliminary demonstration about the relevance of maladaptive intra-cardiac vortex dynamics in the geometrical adaptation of the dysfunctional heart. We employed an in vivo model of patients who present a stable normal heart function in virtue of the cardiac resynchronization therapy (CRT, bi-ventricular pace-maker) and who are expected to develop left ventricle remodeling if pace-maker was switched off. Intra-ventricular fluid dynamics is analyzed by echocardiography (Echo-PIV). Under normal conditions, the flow presents a longitudinal alignment of the intraventricular hemodynamic forces. When pacing is temporarily switched off, flow forces develop a misalignment hammering onto lateral walls, despite no other electro-mechanical change is noticed. Hemodynamic forces result to be the first event that evokes a physiological activity anticipating cardiac changes and could help in the prediction of longer term heart adaptations.

  3. Influence of Slippery Pacemaker Leads on Lead-Induced Venous Occlusion

    Science.gov (United States)

    Yang, Weiguang; Bhatia, Sagar; Obenauf, Dayna; Resse, Max; Esmaily-Moghadam, Mahdi; Feinstein, Jeffrey; Pak, On Shun

    2016-11-01

    The use of medical devices such as pacemakers and implantable cardiac defibrillators have become commonplace to treat arrhythmias. Pacing leads with electrodes are used to send electrical pulses to the heart to treat either abnormally slow heart rates, or abnormal rhythms. Lead induced vessel occlusion, which is commonly seen after placement of pacemaker or ICD leads, may result in lead malfunction and/or SVC syndrome, and makes lead extraction difficult. The association between the anatomic locations at risk for thrombosis and regions of venous stasis have been reported previously. The computational studies reveal obvious flow stasis in the proximity of the leads, due to the no-slip boundary condition imposed on the lead surface. With the advent of recent technologies capable of creating slippery surfaces that can repel complex fluids including blood, we explore computationally how local flow structures may be altered in the regions around the leads when the no-slip boundary condition on the lead surface is relaxed using various slip lengths. The findings evaluate the possibility of mitigating risks of lead-induced thrombosis and occlusion by implementing novel surface conditions (i.e. theoretical coatings) on the leads.

  4. Repetitive nonreentrant ventriculoatrial synchrony: An underrecognized cause of pacemaker-related arrhythmia.

    Science.gov (United States)

    Sharma, Parikshit S; Kaszala, Karoly; Tan, Alex Y; Koneru, Jayanthi N; Shepard, Richard; Ellenbogen, Kenneth A; Huizar, Jose F

    2016-08-01

    Similar to endless loop tachycardia (ELT), repetitive nonreentrant ventriculoatrial synchrony (RNRVAS) is a ventriculoatrial (VA) synchrony pacemaker-mediated arrhythmia. RNRVAS was first described in 1990 and can only occur in the presence of retrograde VA conduction and dual-chamber or cardiac resynchronization devices with tracking (P-synchronous ventricular pacing such as DDD, DDDR) or nontracking pacing modes that allow AV-sequential pacing (DDI, DDIR). RNRVAS is promoted by (1) high lower rate limit or any feature that allows rapid pacing, (2) long AV intervals, or (3) long postventricular atrial refractory period (PVARP). In contrast to ELT, RNRVAS is a less well-recognized form of pacemaker-mediated arrhythmia; thus, unlike ELT, there are no specific device algorithms to prevent, recognize, and terminate RNRVAS. However, RNRVAS has been recently shown to occur frequently. We present a series of cases, some of which were found fortuitously. Owing to its clinical implications, we propose that algorithms should be developed to prevent, identify, and terminate RNRVAS.

  5. O paciente portador de marcapasso cardíaco e a repercussão em seu estilo de vida El Paciente Portador de Marcapaso Cardíaco y la Repercusión en su Estilo de Vida Cardiac Pacemaker Bearer Pacient and the Repercussion in the Lifestyle

    Directory of Open Access Journals (Sweden)

    Mirna Albuquerque Frota

    2007-06-01

    Full Text Available Objetivou-se discutir a repercussão no estilo de vida do paciente portador de marca-passo. Os informantes foram sete usuários que se submeteram ao implante de marca-passo definitivo no Hospital de Messejana - CE, Brasil, de maio a junho de 2004. A análise dos dados foi desenvolvida a partir da categorização dos conteúdos das entrevistas, emergindo como resultado duas categorias temáticas: condições de vida mediante a descoberta da doença e repercussão do autocuidado no estilo de vida no contexto da promoção da saúde. Conclui-se que há necessidade de formar equipes multiprofissionais para atuar com estratégias em educação em saúde, ampliando e divulgando a utilização do marca-passo definitivo, e objetivando a adesão destas pessoas à prática do autocuidado.El objetivo fue discutir la repercusión en el estilo de vida del paciente portador de marcapaso. Los informantes fueron siete usuarios que se sometieron al implante de marcapaso definitivo en el Hospital de Messejana Ceará (Brasil, entre mayo y junio de 2004. El análisis de los datos se desarrolló a partir de la categorización de los contenidos de las entrevistas, surgiendo como resultado dos categorías temáticas: Condiciones de vida mediante el descubrimiento de la enfermedad y repercusión del autocuidado en el estilo de vida en el contexto de la promoción de la salud. Se concluyó que existe la necesidad de formar equipos multiprofesionales para actuar con estrategias en Educación para la Salud, ampliando y divulgando la utilización del marcapasos definitivo, con el objetivo de que estas personas adhieran a la práctica del autocuidado.This study aimed to discuss the repercussion in the lifestyle of the pacemaker bearer patient. The informants were seven patients that were submitted to the definitive pacemaker implant in the Messejana Hospital Ceára (Brazil, from May to June 2004. The data analysis was developed from the categorization of the interviews

  6. Incidental Cardiac Findings on Thoracic Imaging.

    LENUS (Irish Health Repository)

    Kok, Hong Kuan

    2013-02-07

    The cardiac structures are well seen on nongated thoracic computed tomography studies in the investigation and follow-up of cardiopulmonary disease. A wide variety of findings can be incidentally picked up on careful evaluation of the pericardium, cardiac chambers, valves, and great vessels. Some of these findings may represent benign variants, whereas others may have more profound clinical importance. Furthermore, the expansion of interventional and surgical practice has led to the development and placement of new cardiac stents, implantable pacemaker devices, and prosthetic valves with which the practicing radiologist should be familiar. We present a collection of common incidental cardiac findings that can be readily identified on thoracic computed tomography studies and briefly discuss their clinical relevance.

  7. Impact of Pacemaker Lead Characteristics on Pacemaker Related Infection and Heart Perforation: A Nationwide Population-Based Cohort Study.

    Directory of Open Access Journals (Sweden)

    Yu-Sheng Lin

    Full Text Available Several risk factors for pacemaker (PM related complications have been reported. However, no study has investigated the impact of lead characteristics on pacemaker-related complications.Patients who received a new pacemaker implant from January 1997 to December 2011 were selected from the Taiwan National Health Insurance Database. This population was grouped according to the pacemaker lead characteristics in terms of fixation and insulation. The impact of the characteristics of leads on early heart perforation was analyzed by multivariable logistic regression analysis, while the impact of the lead characteristics on early and late infection and late heart perforation over a three-year period were analyzed using Cox regression. This study included 36,104 patients with a mean age of 73.4±12.5 years. In terms of both early and late heart perforations, there were no significant differences between groups across the different types of fixation and insulations. In the multivariable Cox regression analysis, the pacemaker-related infection rate was significantly lower in the active fixation only group compared to either the both fixation (OR, 0.23; 95% CI, 0.07-0.80; P = 0.020 or the passive fixation group (OR, 0.26; 95% CI, 0.08-0.83; P = 0.023.There was no difference in heart perforation between active and passive fixation leads. Active fixation leads were associated with reduced risk of pacemaker-related infection.

  8. Synergism of coupled subsarcolemmal Ca2+ clocks and sarcolemmal voltage clocks confers robust and flexible pacemaker function in a novel pacemaker cell model.

    Science.gov (United States)

    Maltsev, Victor A; Lakatta, Edward G

    2009-03-01

    Recent experimental studies have demonstrated that sinoatrial node cells (SANC) generate spontaneous, rhythmic, local subsarcolemmal Ca(2+) releases (Ca(2+) clock), which occur during late diastolic depolarization (DD) and interact with the classic sarcolemmal voltage oscillator (membrane clock) by activating Na(+)-Ca(2+) exchanger current (I(NCX)). This and other interactions between clocks, however, are not captured by existing essentially membrane-delimited cardiac pacemaker cell numerical models. Using wide-scale parametric analysis of classic formulations of membrane clock and Ca(2+) cycling, we have constructed and initially explored a prototype rabbit SANC model featuring both clocks. Our coupled oscillator system exhibits greater robustness and flexibility than membrane clock operating alone. Rhythmic spontaneous Ca(2+) releases of sarcoplasmic reticulum (SR)-based Ca(2+) clock ignite rhythmic action potentials via late DD I(NCX) over much broader ranges of membrane clock parameters [e.g., L-type Ca(2+) current (I(CaL)) and/or hyperpolarization-activated ("funny") current (I(f)) conductances]. The system Ca(2+) clock includes SR and sarcolemmal Ca(2+) fluxes, which optimize cell Ca(2+) balance to increase amplitudes of both SR Ca(2+) release and late DD I(NCX) as SR Ca(2+) pumping rate increases, resulting in a broad pacemaker rate modulation (1.8-4.6 Hz). In contrast, the rate modulation range via membrane clock parameters is substantially smaller when Ca(2+) clock is unchanged or lacking. When Ca(2+) clock is disabled, the system parametric space for fail-safe SANC operation considerably shrinks: without rhythmic late DD I(NCX) ignition signals membrane clock substantially slows, becomes dysrhythmic, or halts. In conclusion, the Ca(2+) clock is a new critical dimension in SANC function. A synergism of the coupled function of Ca(2+) and membrane clocks confers fail-safe SANC operation at greatly varying rates.

  9. Nonphotic entrainment of the human circadian pacemaker

    Science.gov (United States)

    Klerman, E. B.; Rimmer, D. W.; Dijk, D. J.; Kronauer, R. E.; Rizzo, J. F. 3rd; Czeisler, C. A.

    1998-01-01

    In organisms as diverse as single-celled algae and humans, light is the primary stimulus mediating entrainment of the circadian biological clock. Reports that some totally blind individuals appear entrained to the 24-h day have suggested that nonphotic stimuli may also be effective circadian synchronizers in humans, although the nonphotic stimuli are probably comparatively weak synchronizers, because the circadian rhythms of many totally blind individuals "free run" even when they maintain a 24-h activity-rest schedule. To investigate entrainment by nonphotic synchronizers, we studied the endogenous circadian melatonin and core body temperature rhythms of 15 totally blind subjects who lacked conscious light perception and exhibited no suppression of plasma melatonin in response to ocular bright-light exposure. Nine of these fifteen blind individuals were able to maintain synchronization to the 24-h day, albeit often at an atypical phase angle of entrainment. Nonphotic stimuli also synchronized the endogenous circadian rhythms of a totally blind individual to a non-24-h schedule while living in constant near darkness. We conclude that nonphotic stimuli can entrain the human circadian pacemaker in some individuals lacking ocular circadian photoreception.

  10. Cardiac magnetic resonance imaging: patient safety considerations.

    Science.gov (United States)

    Giroletti, Elio; Corbucci, Giorgio

    Magnetic Resonance Imaging (MRI) is widely used in medicine. In cardiology, it is used to assess congenital or acquired diseases of the heat: and large vessels. Unless proper precautions are taken, it is generally advisable to avoid using this technique in patients with implanted electronic stimulators, such as pacemakers and defibrillators, on account of the potential risk of inducing electrical currents on the endocardial catheters, since these currents might stimulate the heart at a high frequency, thereby triggering dangerous arrhythmias. In addition to providing some basic information on pacemakers, defibrillators and MRI, and on the possible physical phenomena that may produce harmful effects, the present review examines the indications given in the literature, with particular reference to coronary stents, artificial heart valves and implantable cardiac stimulators.

  11. Surgical removal of infected pacemaker leads without cardiopulmonary bypass after failed extraction using the Excimer Laser Sheath Extraction System.

    Science.gov (United States)

    Tokunaga, Chiho; Enomoto, Yoshiharu; Sato, Fujio; Kanemoto, Shinya; Matsushita, Shonosuke; Hiramatsu, Yuji; Aonuma, Kazutaka; Sakakibara, Yuzuru

    2012-03-01

    With the growing number of cardiac pacemakers and internal cardioverter defibrillator implantations, problems with endocardial lead infection have been increasing. The newly developed Excimer Laser Sheath Lead Extraction System has been recognized as being highly useful for removing chronic infected leads. However, serious bleeding complications are a concern when this system is used. Here we report our experience with a 67-year-old man who was diagnosed with pacemaker endocarditis. Initially, lead removal was attempted using the Excimer Laser Sheath Extraction System, though this was abandoned because of severe adhesion of the leads and the junction of the supra vena cava (SVC) with the right atrium. Surgical removal of the leads was performed without using cardiopulmonary bypass and the leads were removed without any complications. During surgery, we found there was a silent perforation of the innominate vein brought about by the Excimer Laser Sheath System. Also, the junction of the SVC with the right atrium was thought to be an area potentially at high risk of perforation, because of a lack of surrounding tissue. It is our opinion that those who carry out procedures with the Excimer Laser Sheath System should understand the potential risk of perforation based on cardiac anatomy and should be prepared for lethal bleeding complications. Also, for emergent situations, we believe that close backup by a cardiovascular surgical team should be considered essential for performing the Excimer Laser Sheath Lead Extraction safely.

  12. Surgical Removal of a Giant Vegetation on Permanent Endocavitary Pacemaker Wire and Lead

    Institute of Scientific and Technical Information of China (English)

    Guo-tao Ma; Qi Miao; Chao-ji Zhang; Li-hua Cao

    2011-01-01

    PACEMAKER lead infections are rare.There are only about 0.4%-1.1% of the patients who have been implanted permanent pacemakers suffering from serious infections which lead to endocarditis.1 Generally,removal of the infected pacemaker wire and lead,long-term anti-infection therapy,and implantation of a new pacemaker to another anatomic site are accepted approaches for these patients.

  13. SYNCHRONIZATION OF TWO COUPLED HINDMARSH-ROSE NEURONS BY A PACEMAKER

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    This paper considers the synchronization of two coupled Hindmarsh-Rose neurons by a pacemaker.Based on the stability theory of differential equations,the complete synchronization of this pacemaker neuron model is reached.Moreover,we also show that pacemaker can enhance or induce synchronization.Numerical simulations are given to illustrate the main results.

  14. 77 FR 37573 - Effective Date of Requirement for Premarket Approval for an Implantable Pacemaker Pulse Generator

    Science.gov (United States)

    2012-06-22

    ... Approval for an Implantable Pacemaker Pulse Generator AGENCY: Food and Drug Administration, HHS. ACTION... protocol (PDP) for implantable pacemaker pulse generators. The Agency has summarized its findings regarding... PMA or notice of completion of a PDP for the implantable pacemaker pulse generator. In accordance...

  15. Electromagnetic interference of implantable cardiac devices from a shoulder massage machine.

    Science.gov (United States)

    Yoshida, Saeko; Fujiwara, Kousaku; Kohira, Satoshi; Hirose, Minoru

    2014-09-01

    Shoulder massage machines have two pads that are driven by solenoid coils to perform a per cussive massage on the shoulders. There have been concerns that such machines might create electromagnetic interference (EMI) in implantable cardiac devices because of the time-varying magnetic fields produced by the alternating current in the solenoid coils. The objective of this study was to investigate the potential EMI from one such shoulder massage machine on implantable cardiac devices. We measured the distribution profile of the magnetic field intensity around the massage machine. Furthermore, we performed an inhibition test and an asynchronous test on an implantable cardiac pacemaker using the standardized Irnich human body model. We examined the events on an implantable cardioverter-defibrillator (ICD) using a pacemaker programmer while the massage machine was in operation. The magnetic field distribution profile exhibited a peak intensity of 212 (A/m) in one of the solenoid coils. The maximal interference distance between the massage machine and the implantable cardiac pacemaker was 28 cm. Ventricular fibrillation was induced when the massage machine was brought near the electrode of the ICD and touched the Irnich human body model. It is necessary to provide a "don't use" warning on the box or the exterior of the massage machines or in the user manuals and to caution patients with implanted pacemakers about the dangers and appropriate usage of massage machines.

  16. Prevalence of E/A wave fusion and A wave truncation in DDD pacemaker patients with complete AV block under nominal AV intervals.

    Directory of Open Access Journals (Sweden)

    Wolfram C Poller

    Full Text Available Optimization of the AV-interval (AVI in DDD pacemakers improves cardiac hemodynamics and reduces pacemaker syndromes. Manual optimization is typically not performed in clinical routine. In the present study we analyze the prevalence of E/A wave fusion and A wave truncation under resting conditions in 160 patients with complete AV block (AVB under the pre-programmed AVI. We manually optimized sub-optimal AVI.We analyzed 160 pacemaker patients with complete AVB, both in sinus rhythm (AV-sense; n = 129 and under atrial pacing (AV-pace; n = 31. Using Doppler analyses of the transmitral inflow we classified the nominal AVI as: a normal, b too long (E/A wave fusion or c too short (A wave truncation. In patients with a sub-optimal AVI, we performed manual optimization according to the recommendations of the American Society of Echocardiography.All AVB patients with atrial pacing exhibited a normal transmitral inflow under the nominal AV-pace intervals (100%. In contrast, 25 AVB patients in sinus rhythm showed E/A wave fusion under the pre-programmed AV-sense intervals (19.4%; 95% confidence interval (CI: 12.6-26.2%. A wave truncations were not observed in any patient. All patients with a complete E/A wave fusion achieved a normal transmitral inflow after AV-sense interval reduction (mean optimized AVI: 79.4 ± 13.6 ms.Given the rate of 19.4% (CI 12.6-26.2% of patients with a too long nominal AV-sense interval, automatic algorithms may prove useful in improving cardiac hemodynamics, especially in the subgroup of atrially triggered pacemaker patients with AV node diseases.

  17. Isolated cardiac involvement in primary amyloidosis: presenting as sick sinus syndrome and heart failure.

    Science.gov (United States)

    Pattanshetty, Deepak J; Bhat, Pradeep K; Chamberlain, Wendy A; Lyons, Matthew R

    2013-01-01

    Cardiac amyloidosis is an infiltrative cardiomyopathy with a grave prognosis. Its clinical manifestations include restrictive cardiomyopathy, diastolic heart failure, conduction defects, and arrhythmias. Isolated cardiac involvement and significant conduction disturbances are reported very infrequently. We report a rare case of isolated cardiac involvement in primary amyloidosis, in a 76-year-old man who initially presented with sick sinus syndrome that necessitated permanent pacemaker insertion. Subsequent symptoms of heart failure led to additional evaluation, including an endomyocardial biopsy that revealed primary cardiac amyloidosis. Medical therapy improved the patient's symptoms, and he was discharged from the hospital in stable condition. In addition to discussing the patient's case, we review the relevant medical literature.

  18. Differentially timed extracellular signals synchronize pacemaker neuron clocks.

    Directory of Open Access Journals (Sweden)

    Ben Collins

    2014-09-01

    Full Text Available Synchronized neuronal activity is vital for complex processes like behavior. Circadian pacemaker neurons offer an unusual opportunity to study synchrony as their molecular clocks oscillate in phase over an extended timeframe (24 h. To identify where, when, and how synchronizing signals are perceived, we first studied the minimal clock neural circuit in Drosophila larvae, manipulating either the four master pacemaker neurons (LNvs or two dorsal clock neurons (DN1s. Unexpectedly, we found that the PDF Receptor (PdfR is required in both LNvs and DN1s to maintain synchronized LNv clocks. We also found that glutamate is a second synchronizing signal that is released from DN1s and perceived in LNvs via the metabotropic glutamate receptor (mGluRA. Because simultaneously reducing Pdfr and mGluRA expression in LNvs severely dampened Timeless clock protein oscillations, we conclude that the master pacemaker LNvs require extracellular signals to function normally. These two synchronizing signals are released at opposite times of day and drive cAMP oscillations in LNvs. Finally we found that PdfR and mGluRA also help synchronize Timeless oscillations in adult s-LNvs. We propose that differentially timed signals that drive cAMP oscillations and synchronize pacemaker neurons in circadian neural circuits will be conserved across species.

  19. [Telemedicine in pacemaker therapy and follow-up].

    Science.gov (United States)

    Schuchert, A

    2009-12-01

    Present-day remote systems for cardiovascular implantable electronic devices (CIEDs) provide, in contrast to previous solutions, a broad range of data about the patient and the implanted device ("remote control"). Telemedicine includes remote monitoring as well as remote follow-up: Remote monitoring is the continual interrogation of the device to detect patient- or device-related adverse events earlier than with standard follow-up visits. Remote follow-up aims to replace scheduled and unscheduled face-to-face follow-up visits due to the interrogation of the automatic pacemaker functions. Currently available remote systems, such as Home Monitoring, CareLink, Merlin.net, and Latitude, have in common that they interrogate the device, send these data to a server, and provide the data to the physician on a secured web site. Automatic wireless interrogation of the device is the preferred solution; however, the devices must have been equipped with a micro-antenna, which is usually restricted to more recent pacemaker models. Knowledge about remote control in pacemaker patients is limited, because most remote applications were evaluated in ICD and CRT patients. While the most frequently reported clinical event in pacemaker patients is atrial fibrillation, the impact in routine clinical follow-up still has to be evaluated in detail. Device-related adverse events are rare. Large, long-term, randomized trials are comparing remote and conventional approaches with the aim of demonstrating the benefits of telemedicine in this patient group.

  20. Pacemaker Related Infective Endocarditis from Staphylococcus Lugdunensis: A Case Report

    Directory of Open Access Journals (Sweden)

    Michael Ward

    2013-01-01

    Full Text Available Staphylococcus lugdunensis is a common skin flora not typically associated with infection. There are, however, several cases reported in the literature of Staphylococcus lugdunensis as a causative bacterium of various infections. This paper reports an additional case of pacemaker associated endocarditis with Staphylococcus lugdunensis as the causative bacterium.

  1. [Aspergillus fumigatus endocarditis in a patient with a biventricular pacemaker].

    Science.gov (United States)

    Cuesta, José M; Fariñas, María C; Rodilla, Irene G; Salesa, Ricardo; de Berrazueta, José R

    2005-05-01

    Aspergillus fumigatus endocarditis is one of the rarest and severest complications in cardiological patients. We describe a patient with an intracardial pacemaker who was diagnosed as having Aspergillus fumigatus endocarditis. Postmortem examination showed a large, Aspergillus-infected thrombus encased in the right ventricle, pulmonary trunk and main pulmonary branches.

  2. Pacemaker dislocation - Truly ectopic activation necessitating surgical treatment

    NARCIS (Netherlands)

    de Kroon, TL; Witsenburg, M; Bogerts, AJJC

    2002-01-01

    Intra-abdominal migration of a generator from an epicardial pacemaker system is a rare but potentially life-threatening complication. We report on a case of a 2-year-old child in whom the generator silently migrated from the sheath of the rectus abdominis muscle in the upper abdominal wall down into

  3. Can Brain 'Pacemaker' Improve Lives of Head Trauma Patients?

    Science.gov (United States)

    ... 161109.html Can Brain 'Pacemaker' Improve Lives of Head Trauma Patients? Deep brain stimulation appears to boost function and quality of life, small study finds To use the sharing ... that's implanted from the head, under the skin, through the neck and shoulders ...

  4. Left ventricular ejection fraction normalization in cardiac resynchronization therapy and risk of ventricular arrhythmias and clinical outcomes

    DEFF Research Database (Denmark)

    Ruwald, Martin H; Solomon, Scott D; Foster, Elyse

    2014-01-01

    within 2.2 years of follow-up. Risk of inappropriate ICD therapy is still present, and these patients could be considered for downgrade from CRT-defibrillator to CRT-pacemaker at the time of battery depletion if no VTAs have occurred. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique...

  5. Cardiac arrest

    Science.gov (United States)

    ... Article.jsp. Accessed June 16, 2014. Myerburg RJ, Castellanos A. Approach to cardiac arrest and life-threatening ... PA: Elsevier Saunders; 2011:chap 63. Myerburg RJ, Castellanos A. Cardiac arrest and audden aardiac death. In: ...

  6. 咪唑啉/α2受体激动剂对兔窦房结起博细胞的电生理效应%Electrophysiological responses to imidazoline/α2-receptor agonists in rabbit sinoatrial node pacemaker cells

    Institute of Scientific and Technical Information of China (English)

    赵丁; 任雷鸣

    2003-01-01

    AIM: To compare the effects of moxonidine (Mox), clonidine (Clo), agmatine (Agm), and xylazine (Xyl) on action potentials (AP) of the rabbit sinoatrial node (SAN) pacemaker cells and investigate the contribution of α-adrenoceptors to the cardiac electrophysiologic responses induced by the agonists. METHODS: Intracellular microelectrode technique was used to record AP in the rabbit SAN pacemaker cells. Vasoconstrictive responses to norepinephrine (NE), Mox, Clo, Agm and Xyl were observed in the thoracic aorta and ear vein isolated from rabbits. RESULTS: (1) In the rabbit thoracic aorta, a rank order of potency producing vasoconstrictive responses was NE>Clo>Mox;and a rank order of potency in ear vein was Clo>NE>Xyl=Mox. Agm did not produce any vascular responses in both preparations, and Xyl did not produce vascular responses in the thoracic aorta. (2) Mox, Clo, Xyl, and Agm concentration-dependently decreased the rate of pacemaker firing (RPF), and prolonged APD50 and APD90 in the rabbit SAN pacemaker cells. The rank order of decreasing RPF or prolonging APD was Clo>Xyl=Mox. (3) Most effects of Clo were partially inhibited by yohimbine, but those of Xyl and all the effects of Agm on the AP in SAN pacemaker cells were not affected by the treatment with yohimbine. (4) In the presence of propranolol 1 μmol/L, phenylephrine did not cause any effects on AP in the rabbit SAN pacemaker cells. CONCLUSION: Like Mox, Clo changes AP of the rabbit SAN pacemaker cells via α2-adrenoceptors partially, but the effects of Xyl and Agm on the AP are almost not related to α2-adrenoceptors. Moreover, there are no obviously functional α1-adrenoceptors in the rabbit SAN pacemaker cells.

  7. Safety of magnetic resonance imaging in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices.

    Science.gov (United States)

    Baikoussis, Nikolaos G; Apostolakis, Efstratios; Papakonstantinou, Nikolaos A; Sarantitis, Ioannis; Dougenis, Dimitrios

    2011-06-01

    Magnetic resonance imaging (MRI) in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices is sometimes a risky procedure. Thus MRI in these patients should be performed when it is the only examination able to help with the diagnosis. Moreover the diagnostic benefit must outweigh the risks. Coronary artery stents, prosthetic cardiac valves, metal sternal sutures, mediastinal vascular clips, and epicardial pacing wires are not contraindications for MRI, in contrast to pacemakers and implantable cardioverter-defibrillators. Appropriate patient selection and precautions ensure MRI safety. However it is commonly accepted that although hundreds of patients with pacemakers or implantable cardioverter-defibrillators have undergone safe MRI scanning, it is not a safe procedure. Currently, heating of the pacemaker lead is the major problem undermining MRI safety. According to the US Food and Drug Administration (FDA), there are currently neither "MRI-safe" nor "MRI-compatible" pacemakers and implantable cardioverter-defibrillators. In this article we review the international literature in regard to safety during MRI of patients with implanted cardiac prostheses and metallic cardiovascular electronic devices.

  8. Bifurcations in a nonlinear model of the baroreceptor-cardiac reflex

    Science.gov (United States)

    Seidel, H.; Herzel, H.

    1998-04-01

    We investigate the dynamic properties of a nonlinear model of the human cardio-baroreceptor control loop. As a new feature we use a phase effectiveness curve to describe the experimentally well-known phase dependency of the cardiac pacemaker's sensitivity to neural activity. We show that an increase of sympathetic time delays leads via a Hopf bifurcation to sustained heart rate oscillations. For increasing baroreflex sensitivity or for repetitive vagal stimulation we observe period-doubling, toroidal oscillations, chaos, and entrainment between the rhythms of the heart and the control loop. The bifurcations depend crucially on the involvement of the cardiac pacemaker's phase dependency. We compare the model output with experimental data from electrically stimulated anesthetized dogs and discuss possible implications for cardiac arrhythmias.

  9. Persistently active, pacemaker-like neurons in neocortex

    Directory of Open Access Journals (Sweden)

    Morgane Le Bon-Jego

    2007-10-01

    Full Text Available The neocortex is spontaneously active, however, the origin of this self-generated, patterned activity remains unknown. To detect potential pacemaker cells, we use calcium imaging to directly identify neurons that discharge action potentials in the absence of synaptic transmissionin slices from juvenile mouse visual cortex. We characterize 60 of these neurons electrophysiologically and morphologically, finding that they belong to two classes of cells: one class composed of pyramidal neurons with a thin apical dendritic tree and a second class composed of ascending axon interneurons (Martinotti cells located in layer 5. In both types of neurons, persistent sodium currents are necessary for the generation of the spontaneous activity. Our data demonstrate that subtypes of neocortical neurons have intrinsic mechanisms to generate persistent activity. Like in central pattern generators (CPGs, these neurons may act as pacemakers to initiate or pattern spontaneous activity in the neocortex.

  10. Transient apical dyskinesia with a pacemaker: Electrocardiographic features.

    Science.gov (United States)

    Núñez-Gil, Iván J; Feltes, Gisela I; Mejía-Rentería, Hernán D; Biagioni, Corina; De Agustín, J Alberto; Vivas, David; Fernández-Ortiz, Antonio

    2015-04-01

    Transient apical dyskinesia syndromes present features similar to acute coronary syndromes, but with normal coronary arteries and rapid complete resolution of wall motion alterations. We report the case of a 73-year-old woman who was admitted to hospital because of typical chest pain at rest after her brother's death. She had had a pacemaker implanted in 2001. Troponin levels were elevated and apical hypokinesia was shown by ventriculography and echocardiography, with normal coronary arteries. Evolving ECG alterations were observed in spite of the continued pacing rhythm. All these alterations were fully resolved after discharge. This case shows that, even in the presence of a pacemaker, evolving ECG alterations can be observed in Takotsubo syndrome.

  11. [Representations, myths, and behaviors among Chagas disease patients with pacemakers].

    Science.gov (United States)

    Magnani, Claudia; Oliveira, Bruna Guimarães; Gontijo, Eliane Dias

    2007-07-01

    This anthropological study aimed to evaluate the incorporation of pacemakers into the lives of individuals with Chagas disease. An ethnographic methodology was used, based on an open interview focusing on the personal perceptions of 15 patients with chronic Chagas cardiopathy who had required pacemaker implants at the Federal University Hospital in Belo Horizonte, Minas Gerais State, Brazil. As part of a broader quality of life analysis, the study investigated the cultural, physical, and psychological resources used by patients to confront, explain, and accept the disease process, including mental representations on the cultural perception of the illness and definition of social relations. The study was intended to contribute to comprehensive patient care by health professionals, including psychosocial aspects. Decoded and integrated orientation in the cultural sphere assumes an important role in order to prevent disinformation from perpetuating the dissemination of popular myths as active elements in patient stigmatization.

  12. Cardiac Resynchronization Therapy and phase resetting of the sinoatrial node: A conjecture

    Science.gov (United States)

    Cantini, Federico; Varanini, Maurizio; Macerata, Alberto; Piacenti, Marcello; Morales, Maria-Aurora; Balocchi, Rita

    2007-03-01

    Congestive heart failure is a severe chronic disease often associated with disorders that alter the mechanisms of excitation-contraction coupling that may result in an asynchronous left ventricular motion which may further impair the ability of the failing heart to eject blood. In recent years a therapeutic approach to resynchronize the ventricles (cardiac resynchronization therapy, CRT) has been performed through the use of a pacemaker device able to provide atrial-based biventricular stimulation. Atrial lead senses the spontaneous occurrence of cells depolarization and sends the information to the generator which, in turn, after a settled delay [atrioventricular (AV) delay], sends electrical impulses to both ventricles to stimulate their synchronous contraction. Recent studies performed on heart rate behavior of chronically implanted patients at different epochs after implantation have shown that CRT can lead to sustained overall improvement of heart function with a reduction in morbidity and mortality. At this moment, however, there are no studies about CRT effects on spontaneous heart activity of chronically implanted patients. We performed an experimental study in which the electrocardiographic signal of five subjects under chronic CRT was recorded during the activity of the pacemaker programmed at different AV delays and under spontaneous cardiac activity after pacemaker deactivation. The different behavior of heart rate variability during pacemaker activity and after pacemaker deactivation suggested the hypothesis of a phase resetting mechanism induced by the pacemaker stimulus on the sinoatrial (SA) node, a phenomenon already known in literature for aggregate of cardiac cells, but still unexplored in vivo. The constraints imposed by the nature of our study (in vivo tests) made it impossible to plan an experiment to prove our hypothesis directly. We therefore considered the best attainable result would be to prove the accordance of our data to the conjecture

  13. Cardiac resynchronization therapy and phase resetting of the sinoatrial node: a conjecture.

    Science.gov (United States)

    Cantini, Federico; Varanini, Maurizio; Macerata, Alberto; Piacenti, Marcello; Morales, Maria-Aurora; Balocchi, Rita

    2007-03-01

    Congestive heart failure is a severe chronic disease often associated with disorders that alter the mechanisms of excitation-contraction coupling that may result in an asynchronous left ventricular motion which may further impair the ability of the failing heart to eject blood. In recent years a therapeutic approach to resynchronize the ventricles (cardiac resynchronization therapy, CRT) has been performed through the use of a pacemaker device able to provide atrial-based biventricular stimulation. Atrial lead senses the spontaneous occurrence of cells depolarization and sends the information to the generator which, in turn, after a settled delay [atrioventricular (AV) delay], sends electrical impulses to both ventricles to stimulate their synchronous contraction. Recent studies performed on heart rate behavior of chronically implanted patients at different epochs after implantation have shown that CRT can lead to sustained overall improvement of heart function with a reduction in morbidity and mortality. At this moment, however, there are no studies about CRT effects on spontaneous heart activity of chronically implanted patients. We performed an experimental study in which the electrocardiographic signal of five subjects under chronic CRT was recorded during the activity of the pacemaker programmed at different AV delays and under spontaneous cardiac activity after pacemaker deactivation. The different behavior of heart rate variability during pacemaker activity and after pacemaker deactivation suggested the hypothesis of a phase resetting mechanism induced by the pacemaker stimulus on the sinoatrial (SA) node, a phenomenon already known in literature for aggregate of cardiac cells, but still unexplored in vivo. The constraints imposed by the nature of our study (in vivo tests) made it impossible to plan an experiment to prove our hypothesis directly. We therefore considered the best attainable result would be to prove the accordance of our data to the conjecture

  14. A Comparative Study on a Tilt-Integral-Derivative Controller with Proportional-Integral-Derivative Controller for a Pacemaker

    Directory of Open Access Journals (Sweden)

    Aysan Esgandanian

    2016-06-01

    Full Text Available The study is done to determine the comparison between proportional-integral-derivative controller (PID controller and tilt-integral-derivative (TID controller for cardiac pacemaker systems, which can automatically control the heart rate to accurately track a desired preset profile. The controller offers good adaption of heart to the physiological needs of the patient. The parameters of the both controllers are tuned by particle swarm optimization (PSO algorithm which uses the integral of time square error as a fitness function to be minimized. Simulation results are performed on the developed cardiovascular system of humans and results demonstrate that the TID controller produces superior control performance than PID controllers. In this paper all simulations were performed in Matlab.

  15. Effects of Lubiprostone on Pacemaker Activity of Interstitial Cells of Cajal from the Mouse Colon

    OpenAIRE

    Jiao, Han-Yi; Kim, Dong Hyun; Ki, Jung Suk; Ryu, Kwon Ho; Choi, Seok; Jun, Jae Yeoul

    2014-01-01

    Lubiprostone is a chloride (Cl-) channel activator derived from prostaglandin E1 and used for managing constipation. In addition, lubiprostone affects the activity of gastrointestinal smooth muscles. Interstitial cells of Cajal (ICCs) are pacemaker cells that generate slow-wave activity in smooth muscles. We studied the effects of lubiprostone on the pacemaker potentials of colonic ICCs. We used the whole-cell patch-clamp technique to determine the pacemaker activity in cultured colonic ICCs ...

  16. Haemophilus parainfluenzae bacteremia associated with a pacemaker wire localized by gallium scan

    Energy Technology Data Exchange (ETDEWEB)

    Rosenbaum, G.S.; Calubiran, O.; Cunha, B.A. (Winthrop-Univ. Hospital, Mineola, NY (USA))

    1990-05-01

    A young woman with a history of sick sinus syndrome and placement of a permanent pacemaker 6 months before admission had fever and Haemophilus parainfluenzae bacteremia. A gallium scan localized the infection to the site of the pacemaker wire. Echocardiograms were negative for any vegetations. The patient responded to cefotaxime and trimethoprim-sulfamethoxazole therapy. We believe that this is the first case of H. parainfluenzae bacteremia associated with a pacemaker wire and localized by gallium scan.

  17. Isolating neural correlates of the pacemaker for food anticipation.

    Directory of Open Access Journals (Sweden)

    Ian David Blum

    Full Text Available Mice fed a single daily meal at intervals within the circadian range exhibit food anticipatory activity. Previous investigations strongly suggest that this behaviour is regulated by a circadian pacemaker entrained to the timing of fasting/refeeding. The neural correlate(s of this pacemaker, the food entrainable oscillator (FEO, whether found in a neural network or a single locus, remain unknown. This study used a canonical property of circadian pacemakers, the ability to continue oscillating after removal of the entraining stimulus, to isolate activation within the neural correlates of food entrainable oscillator from all other mechanisms driving food anticipatory activity. It was hypothesized that continued anticipatory activation of central nuclei, after restricted feeding and a return to ad libitum feeding, would elucidate a neural representation of the signaling circuits responsible for the timekeeping component of the food entrainable oscillator. Animals were entrained to a temporally constrained meal then placed back on ad libitum feeding for several days until food anticipatory activity was abolished. Activation of nuclei throughout the brain was quantified using stereological analysis of c-FOS expressing cells and compared against both ad libitum fed and food entrained controls. Several hypothalamic and brainstem nuclei remained activated at the previous time of food anticipation, implicating them in the timekeeping mechanism necessary to track previous meal presentation. This study also provides a proof of concept for an experimental paradigm useful to further investigate the anatomical and molecular substrates of the FEO.

  18. Nursing procedure in the temporary transvenous pacemaker implantation

    Directory of Open Access Journals (Sweden)

    Mª Teresa Redecillas Peiró

    2013-05-01

    Full Text Available The temporary transvenous pacemaker (MPTT implantation is a technique that consists in stimulating artificially the heart when the natural pacemaker is unable to maintain the rhythm and the appropiate frequency. This type of electric stimulation is carried out by means of an electrocateter that was implanted in the endocardium through a central vein connected to an external generator, requiring equipment and personal with specific abilities. It is commonly carried out in the intensive care units when a continuous temporary stimulation is suitable and in most cases it is carried out in situations of extreme medical urgency in critical and unstable patients. The nursing professionals play an important role in the whole procedure, becoming essential that they possess knowledge not only about technique and handling of the device but also on the performance in all its phases. This research work intends to be a practical reference that gathers those essential aspects for the development of this assistance practice including, in a detailed way, the nursing performance in the preparation, the implantation and the pursuit of the patients who a temporary transvenous pacemaker was placed in.

  19. Cardiac sarcoidosis mimicking right ventricular dysplasia.

    Science.gov (United States)

    Shiraishi, Jun; Tatsumi, Tetsuya; Shimoo, Kazutoshi; Katsume, Asako; Mani, Hiroki; Kobara, Miyuki; Shirayama, Takeshi; Azuma, Akihiro; Nakagawa, Masao

    2003-02-01

    A 59-year-old woman with skin sarcoidosis was admitted to hospital for assessment of complete atrioventricular block. Cross-sectional echocardiography showed that the apical free wall of the right ventricle was thin and dyskinetic with dilation of the right ventricle. Thallium-201 myocardial imaging revealed a normal distribution. Both gallium-67 and technetium-99m pyrophosphate scintigraphy revealed no abnormal uptake in the myocardium. Right ventriculography showed chamber dilation and dyskinesis of the apical free wall, whereas left ventriculography showed normokinesis, mimicking right ventricular dysplasia. Cardiac sarcoidosis was diagnosed on examination of an endomyocardial biopsy specimen from the right ventricle. A permanent pacemaker was implanted to manage the complete atrioventricular block. After steroid treatment, electrocardiography showed first-degree atrioventricular block and echocardiography revealed an improvement in the right ventricular chamber dilation. Reports of cardiac sarcoidosis mimicking right ventricular dysplasia are extremely rare and as this case shows, right ventricular involvement may be one of its manifestations.

  20. TBX18 gene induces adipose-derived stem cells to differentiate into pacemaker-like cells in the myocardial microenvironment

    Science.gov (United States)

    Yang, Mei; Zhang, Ge-Ge; Wang, Teng; Wang, Xi; Tang, Yan-Hong; Huang, He; Barajas-Martinez, Hector; Hu, Dan; Huang, Cong-Xin

    2016-01-01

    T-box 18 (TBX18) plays a crucial role in the formation and development of the head of the sinoatrial node. The objective of this study was to induce adipose-derived stem cells (ADSCs) to produce pacemaker-like cells by transfection with the TBX18 gene. A recombinant adenovirus vector carrying the human TBX18 gene was constructed to transfect ADSCs. The ADSCs transfected with TBX18 were considered the TBX18-ADSCs. The control group was the GFP-ADSCs. The transfected cells were co-cultured with neonatal rat ventricular cardiomyocytes (NRVMs). The results showed that the mRNA expression of TBX18 in TBX18-ADSCs was significantly higher than in the control group after 48 h and 7 days. After 7 days of co-culturing with NRVMs, there was no significant difference in the expression of the myocardial marker cardiac troponin I (cTnI) between the two groups. RT-qPCR and western blot analysis showed that the expression of HCN4 was higher in the TBX18-ADSCs than in the GFP-ADSCs. The If current was detected using the whole cell patch clamp technique and was blocked by the specific blocker CsCl. Human induced pluripotent stem cell-derived cardiomyocytes (hiPSCMs) showed approximately twice the current density compared with the ADSCs. Our study indicated that the TBX18 gene induces ADSCs to differentiate into pacemaker-like cells in the cardiac microenvironment. Although further experiments are required in order to assess safety and efficacy prior to implementation in clinical practice, this technique may provide new avenues for the clinical therapy of bradycardia. PMID:27632938

  1. Permanent pacemaker lead induced severe tricuspid regurgitation in patient undergoing multiple valve surgery.

    Science.gov (United States)

    Lee, Jung Hee; Kim, Tae Ho; Kim, Wook Sung

    2015-04-01

    Severe and permanent tricuspid regurgitation induced by pacemaker leads is rarely reported in the literature. The mechanism of pacemaker-induced tricuspid regurgitation has been identified, but its management has not been well established. Furthermore, debate still exists regarding the proper surgical approach. We present the case of a patient with severe tricuspid regurgitation induced by a pacemaker lead, accompanied by triple valve disease. The patient underwent double valve replacement and tricuspid valve repair without removal of the pre-existing pacemaker lead. The operation was successful and the surgical procedure is discussed in detail.

  2. Cardiac Sarcoidosis.

    Science.gov (United States)

    Birnie, David; Ha, Andrew C T; Gula, Lorne J; Chakrabarti, Santabhanu; Beanlands, Rob S B; Nery, Pablo

    2015-12-01

    Studies suggest clinically manifest cardiac involvement occurs in 5% of patients with pulmonary/systemic sarcoidosis. The principal manifestations of cardiac sarcoidosis (CS) are conduction abnormalities, ventricular arrhythmias, and heart failure. Data indicate that an 20% to 25% of patients with pulmonary/systemic sarcoidosis have asymptomatic (clinically silent) cardiac involvement. An international guideline for the diagnosis and management of CS recommends that patients be screened for cardiac involvement. Most studies suggest a benign prognosis for patients with clinically silent CS. Immunosuppression therapy is advocated for clinically manifest CS. Device therapy, with implantable cardioverter defibrillators, is recommended for some patients.

  3. Pacemaker implantation in a patient with brugada and sick sinus syndrome.

    Science.gov (United States)

    Risgaard, Bjarke; Bundgaard, Henning; Jabbari, Reza; Haunsø, Stig; Winkel, Bo Gregers; Tfelt-Hansen, Jacob

    2013-03-26

    Brugada syndrome (BrS) is a rare and inherited primary arrhythmic syndrome characterized by ST-segment elevations in the right precordial leads (V1-V3) with an increased risk of sudden cardiac death (SCD). Arrhythmias in BrS are often nocturne, and brady-arrhythmias are often seen in patients with loss-of-function mutations in SCN5A. In this case-report we present a 75-year old woman referred to our outpatient clinic for inherited cardiac diseases for a familial clinical work-up. Since childhood she had suffered from dizziness, absence seizures, and countless Syncope's. In 2004 sick sinus syndrome was suspected and she was treated with implantation of a pacemaker (PM) at another institution. An inherited cardiac disease was one day suddenly suspected, as the patient had a 61-year old brother who was diagnosed with symptomatic BrS, and treated with an implantable cardioverter defibrillator (ICD) after aborted SCD. A mutation screening revealed a SCN5A [S231CfsX251 (c.692-693delCA)] loss-of-function mutation not previously reported, and as a part of the cascade screening in relatives she was therefore referred to our clinic. In the 7 year period after PM implantation she had experienced no cardiac symptoms, although her electrocardiogram changes now were consistent with a BrS type 1 pattern. A genetic test confirmed that she had the same mutation in SCN5A as her brother. In this case-report we present a loss-of function mutation in SCN5A not previously associated with BrS nor presented in healthy controls. Sinus node dysfunction has previously been documented in patients with symptomatic BrS, which suggests it is not a rare concomitant. The only accepted treatment of BrS is today implantation of an ICD. In the future studies should evaluate if PM in some cases of symptomatic BrS can be used instead of ICDs in patients with a loss-of-function SCN5A mutations.

  4. SUB-ARACHNOID BLOCK FOR AN ELDERLY PATIENT WITH CHRONIC RENAL FAILURE, RIGHT SIDE LOCULATED PNEUMOTHORAX AND WITH COMPLETE HEART BLOCK ON PACEMAKER

    Directory of Open Access Journals (Sweden)

    Krishna Prabu

    2014-05-01

    Full Text Available : Patients presenting for an elective or emergency surgery with pre-existing chronic renal failure (CRF has certain anesthetic considerations. Central neuraxial block for these patients is controversial, because all these patients will be invariably on fluid restriction. If such patient presents with pulmonary complications and cardiac complications which are relative contraindications for general anesthesia then the anesthetic management becomes trickier. We had a patient with CRF, presented with inter-trochanteric fracture of femur for surgical fixation. The patient also had left side loculated pneumothorax, right side bronchiectatic changes and permanent cardiac pacemaker for complete heart block which were challenges for general anesthesia too. Finally the surgery was done under central neuraxial block with dopamine support successfully.

  5. Cardiac Malpositions

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Shi Joon; Im, Chung Gie; Yeon, Kyung Mo; Hasn, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1979-06-15

    Cardiac Malposition refers to any position of the heart other than a left-sided heart in a situs solitus individual. Associated cardiac malformations are so complex that even angiocardiographic and autopsy studies may not afford an accurate information. Although the terms and classifications used to describe the internal cardiac anatomy and their arterial connections in cardiac malpositions differ and tend to be confusing, common agreement exists on the need for a segmental approach to diagnosis. Authors present 18 cases of cardiac malpositions in which cardiac catheterization and angiocardiography were done at the Department of Radiology, Seoul National University Hospital between 1971 and 1979. Authors analyzed the clinical, radiographic, operative and autopsy findings with the emphasis on the angiocardiographic findings. The results are as follows: 1. Among 18 cases with cardiac malpositions, 6 cases had dextrocardia with situs inversus, 9 cases had dextrocardia with situs solitus and 3 cases had levocardia with situs inversus. 2. There was no genuine exception to visceroatrial concordance rule. 3. Associated cardiac malpositions were variable and complex with a tendency of high association of transposition and double outlet varieties with dextrocardia in situs solitus and levocardia in situs inversus. Only one in 6 cases of dextrocardia with situs inversus had pure transposition. 4. In two cases associated pulmonary atresia was found at surgery which was not predicted by angiocardiography. 5. Because many of the associated complex lesions can be corrected surgically provided the diagnosis is accurate, the selective biplane angiocardiography with or without cineradiography is essential.

  6. From syncitium to regulated pump: a cardiac muscle cellular update.

    Science.gov (United States)

    Korzick, Donna H

    2011-03-01

    The primary purpose of this article is to present a basic overview of some key teaching concepts that should be considered for inclusion in an six- to eight-lecture introductory block on the regulation of cardiac performance for graduate students. Within the context of cardiac excitation-contraction coupling, this review incorporates information on Ca(2+) microdomains and local control theory, with particular emphasis on the role of Ca(2+) sparks as a key regulatory component of ventricular myocyte contraction dynamics. Recent information pertaining to local Ca(2+) cycling in sinoatrial nodal cells (SANCs) as a mechanism underlying cardiac automaticity is also presented as part of the recently described coupled-clock pacemaker system. The details of this regulation are emerging; however, the notion that the sequestration and release of Ca(2+) from internal stores in SANCs (similar to that observed in ventricular myocytes) regulates the rhythmic excitation of the heart (i.e., membrane ion channels) is an important advancement in this area. The regulatory role of cardiac adrenergic receptors on cardiac rate and function is also included, and fundamental concepts related to intracellular signaling are discussed. An important point of emphasis is that whole organ cardiac dynamics can be traced back to cellular events regulating intracellular Ca(2+) homeostasis and, as such, provides an important conceptual framework from which students can begin to think about whole organ physiology in health and disease. Greater synchrony of Ca(2+)-regulatory mechanisms between ventricular and pacemaker cells should enhance student comprehension of complex regulatory phenomenon in cardiac muscle.

  7. A forced desynchrony study of circadian pacemaker characteristics in seasonal affective disorder

    NARCIS (Netherlands)

    Koorengevel, Kathelijne M.; Beersma, Domien G.M.; den Boer, Johan; Hoofdakker, Rutger H. van den

    2002-01-01

    The circadian pacemaker is an endogenous clock that regulates oscillations in most physiological and psychological processes with a near 24-h period. In many species, this pacemaker triggers seasonal changes in behavior. The seasonality of symptoms and the efficacy of light therapy suggest involveme

  8. Twiddler-syndrom er en årsag til pacemaker elektrode displacering

    DEFF Research Database (Denmark)

    Grønbech, Keea Treu; Hansen, Michael Gilså

    2013-01-01

    Twiddler's syndrome is a rare cause of pacemaker electrode displacement. The displacement is caused by the patient's manipulation with the pacemaker, so the electrode is retracted. We describe a case of a 79-year-old overweight woman with a known psychiatric anamnesis, who was admitted twice...

  9. Implanted cardiac devices are reliably detected by commercially available metal detectors

    DEFF Research Database (Denmark)

    Holm, Katja Fiedler; Hjortshøj, Søren; Pehrson, Steen;

    2013-01-01

    Explosions of Cardiovascular Implantable Electronic Devices (CIEDs) (pacemakers, defibrillators, and loop recorders) are a well-recognized problem during cremation, due to lithium-iodine batteries. In addition, burial of the deceased with a CIED can present a potential risk for environmental cont...... contamination. Therefore, detection of CIEDs in the deceased would be of value. This study evaluated a commercially available metal detector for detecting CIEDs....

  10. Enhancement of Spontaneous Activity by HCN4 Overexpression in Mouse Embryonic Stem Cell-Derived Cardiomyocytes - A Possible Biological Pacemaker.

    Directory of Open Access Journals (Sweden)

    Yukihiro Saito

    Full Text Available Establishment of a biological pacemaker is expected to solve the persisting problems of a mechanical pacemaker including the problems of battery life and electromagnetic interference. Enhancement of the funny current (If flowing through hyperpolarization-activated cyclic nucleotide-gated (HCN channels and attenuation of the inward rectifier K+ current (IK1 flowing through inward rectifier potassium (Kir channels are essential for generation of a biological pacemaker. Therefore, we generated HCN4-overexpressing mouse embryonic stem cells (mESCs and induced cardiomyocytes that originally show poor IK1 currents, and we investigated whether the HCN4-overexpressing mESC-derived cardiomyocytes (mESC-CMs function as a biological pacemaker in vitro.The rabbit Hcn4 gene was transfected into mESCs, and stable clones were selected. mESC-CMs were generated via embryoid bodies and purified under serum/glucose-free and lactate-supplemented conditions. Approximately 90% of the purified cells were troponin I-positive by immunostaining. In mESC-CMs, expression level of the Kcnj2 gene encoding Kir2.1, which is essential for generation of IK1 currents that are responsible for stabilizing the resting membrane potential, was lower than that in an adult mouse ventricle. HCN4-overexpressing mESC-CMs expressed about a 3-times higher level of the Hcn4 gene than did non-overexpressing mESC-CMs. Expression of the Cacna1h gene, which encodes T-type calcium channel and generates diastolic depolarization in the sinoatrial node, was also confirmed. Additionally, genes required for impulse conduction including Connexin40, Connexin43, and Connexin45 genes, which encode connexins forming gap junctions, and the Scn5a gene, which encodes sodium channels, are expressed in the cells. HCN4-overexpressing mESC-CMs showed significantly larger If currents and more rapid spontaneous beating than did non-overexpressing mESC-CMs. The beating rate of HCN4-overexpressing mESC-CMs responded

  11. Evaluation of the Genetic Basis of Familial Aggregation of Pacemaker Implantation by a Large Next Generation Sequencing Panel.

    Directory of Open Access Journals (Sweden)

    Patrícia B S Celestino-Soper

    Full Text Available The etiology of conduction disturbances necessitating permanent pacemaker (PPM implantation is often unknown, although familial aggregation of PPM (faPPM suggests a possible genetic basis. We developed a pan-cardiovascular next generation sequencing (NGS panel to genetically characterize a selected cohort of faPPM.We designed and validated a custom NGS panel targeting the coding and splicing regions of 246 genes with involvement in cardiac pathogenicity. We enrolled 112 PPM patients and selected nine (8% with faPPM to be analyzed by NGS.Our NGS panel covers 95% of the intended target with an average of 229x read depth at a minimum of 15-fold depth, reaching a SNP true positive rate of 98%. The faPPM patients presented with isolated cardiac conduction disease (ICCD or sick sinus syndrome (SSS without overt structural heart disease or identifiable secondary etiology. Three patients (33.3% had heterozygous deleterious variants previously reported in autosomal dominant cardiac diseases including CCD: LDB3 (p.D117N and TRPM4 (p.G844D variants in patient 4; TRPM4 (p.G844D and ABCC9 (p.V734I variants in patient 6; and SCN5A (p.T220I and APOB (p.R3527Q variants in patient 7.FaPPM occurred in 8% of our PPM clinic population. The employment of massive parallel sequencing for a large selected panel of cardiovascular genes identified a high percentage (33.3% of the faPPM patients with deleterious variants previously reported in autosomal dominant cardiac diseases, suggesting that genetic variants may play a role in faPPM.

  12. Optogenetics for in vivo cardiac pacing and resynchronization therapies.

    Science.gov (United States)

    Nussinovitch, Udi; Gepstein, Lior

    2015-07-01

    Abnormalities in the specialized cardiac conduction system may result in slow heart rate or mechanical dyssynchrony. Here we apply optogenetics, widely used to modulate neuronal excitability, for cardiac pacing and resynchronization. We used adeno-associated virus (AAV) 9 to express the Channelrhodopsin-2 (ChR2) transgene at one or more ventricular sites in rats. This allowed optogenetic pacing of the hearts at different beating frequencies with blue-light illumination both in vivo and in isolated perfused hearts. Optical mapping confirmed that the source of the new pacemaker activity was the site of ChR2 transgene delivery. Notably, diffuse illumination of hearts where the ChR2 transgene was delivered to several ventricular sites resulted in electrical synchronization and significant shortening of ventricular activation times. These findings highlight the unique potential of optogenetics for cardiac pacing and resynchronization therapies.

  13. The role of 3D and speckle tracking echocardiography in cardiac amyloidosis: a case report.

    Science.gov (United States)

    Nucci, E M; Lisi, M; Cameli, M; Baldi, L; Puccetti, L; Mondillo, S; Favilli, R; Lunghetti, S

    2014-01-01

    Cardiac amyloidosis (CA) is a disorder characterized by amyloid fibrils deposition in cardiac interstitium; it results in a restrictive cardiomyopathy with heart failure (HF) and conduction abnormalities. The "gold standard" for diagnosis of CA is myocardial biopsy but possible sampling errors and procedural risks, limit it's use. Magnetic resonance (RMN) offers more information than traditional echocardiography and allows diagnosis of CA but often it's impossible to perform. We report the case of a man with HF and symptomatic bradyarrhythmia that required an urgent pacemaker implant. Echocardiography was strongly suggestive of CA but wasn't impossible to perform an RMN to confirm this hypothesis because the patient was implanted with a definitive pacemaker. So was performed a Speckle Tracking Echocardiography (STE) and a 3D echocardiography: STE allows to differentiate CA from others hypertrophic cardiomyopathy by longitudinal strain value eco 3D and STE for early diagnosis of CA, especially when RMN cannot be performed.

  14. A pilot study of a mindfulness based stress reduction program in adolescents with implantable cardioverter defibrillators or pacemakers.

    Science.gov (United States)

    Freedenberg, Vicki A; Thomas, Sue A; Friedmann, Erika

    2015-04-01

    Adolescents with implantable cardioverter defibrillators (ICDs) or pacemakers (PMs) face unique challenges that can cause psychosocial distress. Psychosocial interventions are effective for adults with cardiac devices and could potentially impact adolescents' adjustment to these devices. Mindfulness Based Stress Reduction (MBSR) is a structured psycho-educational program that includes meditation, yoga, and group support and has been studied extensively among adults. This study examined the feasibility of the MBSR program for adolescents with ICDs/PMs, a population previously unexamined in the research literature. The participants completed measures of anxiety and depression (Hospital Anxiety and Depression Scale) and coping (Responses to Stress Questionnaire) at baseline and after the six-session MBSR intervention. Mean age of the cohort (n = 10) was 15 ± 3 years, 6 were male, 6 had a PM, and 4 had an ICD. Feasibility was demonstrated by successful recruitment of 10 participants, 100 % participation and completion. Anxiety decreased significantly following the intervention, with a large effect size, t[9] = 3.67, p MBSR interventions in adolescents with high-risk cardiac diagnoses.

  15. Nerves projecting from the intrinsic cardiac ganglia of the pulmonary veins modulate sinoatrial node pacemaker function

    Science.gov (United States)

    Zarzoso, Manuel; Rysevaite, Kristina; Milstein, Michelle L.; Calvo, Conrado J.; Kean, Adam C.; Atienza, Felipe; Pauza, Dainius H.; Jalife, José; Noujaim, Sami F.

    2013-01-01

    Aims Pulmonary vein ganglia (PVG) are targets for atrial fibrillation ablation. However, the functional relevance of PVG to the normal heart rhythm remains unclear. Our aim was to investigate whether PVG can modulate sinoatrial node (SAN) function. Methods and results Forty-nine C57BL and seven Connexin40+/EGFP mice were studied. We used tyrosine-hydroxylase (TH) and choline-acetyltransferase immunofluorescence labelling to characterize adrenergic and cholinergic neural elements. PVG projected postganglionic nerves to the SAN, which entered the SAN as an extensive, mesh-like neural network. PVG neurones were adrenergic, cholinergic, and biphenotypic. Histochemical characterization of two human embryonic hearts showed similarities between mouse and human neuroanatomy: direct neural communications between PVG and SAN. In Langendorff perfused mouse hearts, PVG were stimulated using 200–2000 ms trains of pulses (300 μs, 400 µA, 200 Hz). PVG stimulation caused an initial heart rate (HR) slowing (36 ± 9%) followed by acceleration. PVG stimulation in the presence of propranolol caused HR slowing (43 ± 13%) that was sustained over 20 beats. PVG stimulation with atropine progressively increased HR. Time-course effects were enhanced with 1000 and 2000 ms trains (P < 0.05 vs. 200 ms). In optical mapping, PVG stimulation shifted the origin of SAN discharges. In five paroxysmal AF patients undergoing pulmonary vein ablation, application of radiofrequency energy to the PVG area during sinus rhythm produced a decrease in HR similar to that observed in isolated mouse hearts. Conclusion PVG have functional and anatomical biphenotypic characteristics. They can have significant effects on the electrophysiological control of the SAN. PMID:23559611

  16. Cardiac cameras.

    Science.gov (United States)

    Travin, Mark I

    2011-05-01

    Cardiac imaging with radiotracers plays an important role in patient evaluation, and the development of suitable imaging instruments has been crucial. While initially performed with the rectilinear scanner that slowly transmitted, in a row-by-row fashion, cardiac count distributions onto various printing media, the Anger scintillation camera allowed electronic determination of tracer energies and of the distribution of radioactive counts in 2D space. Increased sophistication of cardiac cameras and development of powerful computers to analyze, display, and quantify data has been essential to making radionuclide cardiac imaging a key component of the cardiac work-up. Newer processing algorithms and solid state cameras, fundamentally different from the Anger camera, show promise to provide higher counting efficiency and resolution, leading to better image quality, more patient comfort and potentially lower radiation exposure. While the focus has been on myocardial perfusion imaging with single-photon emission computed tomography, increased use of positron emission tomography is broadening the field to include molecular imaging of the myocardium and of the coronary vasculature. Further advances may require integrating cardiac nuclear cameras with other imaging devices, ie, hybrid imaging cameras. The goal is to image the heart and its physiological processes as accurately as possible, to prevent and cure disease processes.

  17. Cause and Long-Term Outcome of Cardiac Tamponade.

    Science.gov (United States)

    Sánchez-Enrique, Cristina; Nuñez-Gil, Iván J; Viana-Tejedor, Ana; De Agustín, Alberto; Vivas, David; Palacios-Rubio, Julián; Vilchez, Jean Paul; Cecconi, Alberto; Macaya, Carlos; Fernández-Ortiz, Antonio

    2016-02-15

    Cardiac tamponade is a life-threatening condition, whose current specific cause and outcome are unknown. Our purpose was to analyze it. We performed a retrospective observational study with prospective follow-up data including 136 consecutive patients admitted with diagnosis of cardiac tamponade, from 2003 to 2013. We thoroughly recorded variables as clinical features, drainage/pericardiocentesis, fluid characteristics, and long-term events (new cardiac tamponade ± death). The median age was 65 ± 17 years (55% men). In the baseline characteristics, 70% were no smokers, 12% were on anticoagulation, and 13 had suffered a previous myocardial infarction. In the preceding month, 15 patients had undergone a cardiac catheterization, 5 cardiac surgery, and 5 pacemaker insertion. Fever was observed in 16% of patients and 21% displayed other inflammatory symptoms. In 81% of patients, pericardiocentesis was needed. The fluid was hemorrhagic or a transudate in the majority, with positive cytology in 15% and bacteria in 3.7%. Main causes were malignancy (32%), infection (24%), idiopathic (16%), iatrogenic (15%), postmyocardial infarction (7%), uremic (4%), and other causes (2%). After a maximum follow-up of 10.4 years, cardiac tamponade recurred in 10% of the cases (62% in the neoplastic group) and the 48% of patients died (89% in the neoplastic cohort). In conclusion, most cardiac tamponades are due to malignancy, having this specific cause a poorer outcome, probably as a manifestation of an advanced disease. The rest of causes, after an aggressive intensive management, have a good prognosis, especially the iatrogenic.

  18. Memel's Batteries

    Directory of Open Access Journals (Sweden)

    Alexander F. Mitrofanov

    2015-12-01

    Full Text Available The article describes the history and equipment of the coastal and antiaircraft artillery batteries of German Navy (Kriegsmarine constructed in Memel area before and during the World War. There is given the brief description of the Soviet Navy stationed in the area in the postwar years.

  19. Management of radiation oncology patients with a pacemaker or ICD: A new comprehensive practical guideline in The Netherlands

    Directory of Open Access Journals (Sweden)

    Hurkmans Coen W

    2012-11-01

    Full Text Available Abstract Current clinical guidelines for the management of radiotherapy patients having either a pacemaker or implantable cardioverter defibrillator (both CIEDs: Cardiac Implantable Electronic Devices do not cover modern radiotherapy techniques and do not take the patient’s perspective into account. Available data on the frequency and cause of CIED failure during radiation therapy are limited and do not converge. The Dutch Society of Radiotherapy and Oncology (NVRO initiated a multidisciplinary task group consisting of clinical physicists, cardiologists, radiation oncologists, pacemaker and ICD technologists to develop evidence based consensus guidelines for the management of CIED patients. CIED patients receiving radiotherapy should be categorised based on the chance of device failure and the clinical consequences in case of failure. Although there is no clear cut-off point nor a clear linear relationship, in general, chances of device failure increase with increasing doses. Clinical consequences of device failures like loss of pacing, carry the most risks in pacing dependent patients. Cumulative dose and pacing dependency have been combined to categorise patients into low, medium and high risk groups. Patients receiving a dose of less than 2 Gy to their CIED are categorised as low risk, unless pacing dependent since then they are medium risk. Between 2 and 10 Gy, all patients are categorised as medium risk, while above 10 Gy every patient is categorised as high risk. Measures to secure patient safety are described for each category. This guideline for the management of CIED patients receiving radiotherapy takes into account modern radiotherapy techniques, CIED technology, the patients’ perspective and the practical aspects necessary for the safe management of these patients. The guideline is implemented in The Netherlands in 2012 and is expected to find clinical acceptance outside The Netherlands as well.

  20. Anaesthesia Application for Cardiac Denervation in a Patient with Long QT Syndrome and Cardiomyopathy

    Science.gov (United States)

    Karadeniz, Ümit; Demir, Aslı; Koçulu, Rabia

    2016-01-01

    Long QT syndrome is a congenital disorder that is characterized by a prolongation of the QT interval on electrocardiograms and a propensity to ventricular tachyarrhythmias, which may lead to syncope, cardiac arrest or sudden death. Cardiomyopathy and pulmonary hypertension diseases have additional risks in anaesthesia management. In this study, we emphasize on one lung ventilation, pacemaker-implantable cardioverter–defibrillator and the anaesthesia management process in a patient with long QT syndrome, cardiomyopathy and pulmonary hypertension who underwent thoracic sympathectomy. PMID:27366557

  1. Computer-based analysis of cardiac state using entropies, recurrence plots and Poincare geometry.

    Science.gov (United States)

    Chua, K C; Chandran, V; Acharya, U R; Lim, C M

    2008-01-01

    Heart rate variability refers to the regulation of the sinoatrial node, the natural pacemaker of the heart by the sympathetic and parasympathetic branches of the autonomic nervous system. Heart rate variability is important because it provides a window to observe the heart's ability to respond to normal regulatory impulses that affect its rhythm. A computer-based intelligent system for analysis of cardiac states is very useful in diagnostics and disease management. Parameters are extracted from the heart rate signals and analysed using computers for diagnostics. This paper describes the analysis of normal and seven types of cardiac abnormal signals using approximate entropy (ApEn), sample entropy (SampEn), recurrence plots and Poincare plot patterns. Ranges of these parameters for various cardiac abnormalities are presented with an accuracy of more than 95%. Among the two entropies, ApEn showed better performance for all the cardiac abnormalities. Typical Poincare and recurrence plots are shown for various cardiac abnormalities.

  2. Batteries: Overview of Battery Cathodes

    Energy Technology Data Exchange (ETDEWEB)

    Doeff, Marca M

    2010-07-12

    The very high theoretical capacity of lithium (3829 mAh/g) provided a compelling rationale from the 1970's onward for development of rechargeable batteries employing the elemental metal as an anode. The realization that some transition metal compounds undergo reductive lithium intercalation reactions reversibly allowed use of these materials as cathodes in these devices, most notably, TiS{sub 2}. Another intercalation compound, LiCoO{sub 2}, was described shortly thereafter but, because it was produced in the discharged state, was not considered to be of interest by battery companies at the time. Due to difficulties with the rechargeability of lithium and related safety concerns, however, alternative anodes were sought. The graphite intercalation compound (GIC) LiC{sub 6} was considered an attractive candidate but the high reactivity with commonly used electrolytic solutions containing organic solvents was recognized as a significant impediment to its use. The development of electrolytes that allowed the formation of a solid electrolyte interface (SEI) on surfaces of the carbon particles was a breakthrough that enabled commercialization of Li-ion batteries. In 1990, Sony announced the first commercial batteries based on a dual Li ion intercalation system. These devices are assembled in the discharged state, so that it is convenient to employ a prelithiated cathode such as LiCoO{sub 2} with the commonly used graphite anode. After charging, the batteries are ready to power devices. The practical realization of high energy density Li-ion batteries revolutionized the portable electronics industry, as evidenced by the widespread market penetration of mobile phones, laptop computers, digital music players, and other lightweight devices since the early 1990s. In 2009, worldwide sales of Li-ion batteries for these applications alone were US$ 7 billion. Furthermore, their performance characteristics (Figure 1) make them attractive for traction applications such as

  3. Batteries: Overview of Battery Cathodes

    Energy Technology Data Exchange (ETDEWEB)

    Doeff, Marca M

    2010-07-12

    The very high theoretical capacity of lithium (3829 mAh/g) provided a compelling rationale from the 1970's onward for development of rechargeable batteries employing the elemental metal as an anode. The realization that some transition metal compounds undergo reductive lithium intercalation reactions reversibly allowed use of these materials as cathodes in these devices, most notably, TiS{sub 2}. Another intercalation compound, LiCoO{sub 2}, was described shortly thereafter but, because it was produced in the discharged state, was not considered to be of interest by battery companies at the time. Due to difficulties with the rechargeability of lithium and related safety concerns, however, alternative anodes were sought. The graphite intercalation compound (GIC) LiC{sub 6} was considered an attractive candidate but the high reactivity with commonly used electrolytic solutions containing organic solvents was recognized as a significant impediment to its use. The development of electrolytes that allowed the formation of a solid electrolyte interface (SEI) on surfaces of the carbon particles was a breakthrough that enabled commercialization of Li-ion batteries. In 1990, Sony announced the first commercial batteries based on a dual Li ion intercalation system. These devices are assembled in the discharged state, so that it is convenient to employ a prelithiated cathode such as LiCoO{sub 2} with the commonly used graphite anode. After charging, the batteries are ready to power devices. The practical realization of high energy density Li-ion batteries revolutionized the portable electronics industry, as evidenced by the widespread market penetration of mobile phones, laptop computers, digital music players, and other lightweight devices since the early 1990s. In 2009, worldwide sales of Li-ion batteries for these applications alone were US$ 7 billion. Furthermore, their performance characteristics (Figure 1) make them attractive for traction applications such as

  4. Implementation study of an analog spiking neural network for assisting cardiac delay prediction in a cardiac resynchronization therapy device.

    Science.gov (United States)

    Sun, Qing; Schwartz, François; Michel, Jacques; Herve, Yannick; Dalmolin, Renzo

    2011-06-01

    In this paper, we aim at developing an analog spiking neural network (SNN) for reinforcing the performance of conventional cardiac resynchronization therapy (CRT) devices (also called biventricular pacemakers). Targeting an alternative analog solution in 0.13- μm CMOS technology, this paper proposes an approach to improve cardiac delay predictions in every cardiac period in order to assist the CRT device to provide real-time optimal heartbeats. The primary analog SNN architecture is proposed and its implementation is studied to fulfill the requirement of very low energy consumption. By using the Hebbian learning and reinforcement learning algorithms, the intended adaptive CRT device works with different functional modes. The simulations of both learning algorithms have been carried out, and they were shown to demonstrate the global functionalities. To improve the realism of the system, we introduce various heart behavior models (with constant/variable heart rates) that allow pathologic simulations with/without noise on the signals of the input sensors. The simulations of the global system (pacemaker models coupled with heart models) have been investigated and used to validate the analog spiking neural network implementation.

  5. Ventricular oversensing of atrial electrical activity that inhibits VVI pacemaker and causes syncope

    Directory of Open Access Journals (Sweden)

    Elibet Chávez González

    2015-10-01

    Full Text Available Far-field oversensing of atrial electrical activity caused by a VVI pacemaker is a rare phenomenon; however, it may have serious clinical consequences. It has several causes and its timely identification may avoid a possible ventricular asystole. This article reports the case of a 72-year-old male who had a Biotronik Axios SR pacemaker implanted, in VVIR mode, six years ago, due to blocked atrial fibrillation. He suffered syncope due to pacemaker inhibition caused by ventricular oversensing of atrial electrical activity.

  6. Subjective consequences of permanent pacemaker therapy in patients under the age of retirement

    DEFF Research Database (Denmark)

    Mickley, H; Petersen, J; Nielsen, B L

    1989-01-01

    or a sensation of "impulses"/palpitations. To the majority (49 patients or 68.1%) pacemaker treatment did not influence quality of sexual activity. Six patients (8.3%) perceived an improvement, whereas a corresponding number felt deterioration in sexual activity following pacemaker implantation. Pacemaker...... pronounced in subjects suffering from syncope and/or dizziness. Eight patients (11.1%) perceived anxiety most frequently due to fear of pacing failure. Physical complaints were present in 17 patients (23.6%), and the discomfort was mainly due to the size of generator, pain/tenderness from the scar...

  7. Cardiac arrhythmias during exercise testing in healthy men.

    Science.gov (United States)

    Beard, E. F.; Owen, C. A.

    1973-01-01

    Clinically healthy male executives who participate in a long-term physical conditioning program have demonstrated cardiac arrhythmia during and after periodic ergometric testing at submaximal and maximal levels. In 1,385 tests on 248 subjects, it was found that 34% of subjects demonstrated an arrhythmia at some time and 13% of subjects developed arrhythmia on more than one test. Premature systoles of ventricular origin were most common, but premature systoles of atrial origin, premature systoles of junctional origin, paroxysmal atrial tachycardia, atrioventricular block, wandering pacemaker, and pre-excitation were also seen. Careful post-test monitoring and pulse rate regulated training sessions are suggested for such programs.

  8. [Possibilities of minimal invasive cardiac catheter interventions in the dog].

    Science.gov (United States)

    Glaus, T M; Unterer, S; Tomsa, K; Baumgartner, C; Geissbühler, U; Gardelle, O; Reusch, C

    2003-09-01

    The therapeutic possibilities in veterinary cardiology have developed rapidly in the past few years. Whereas until recently cardiac intervention in dogs could only be performed by thoracotomy, new minimally invasive techniques are adopted. Procedures like balloondilatation of pulmonic stenosis, coil embolisation of patent ductus arteriosus, pacemaker implantation in symptomatic bradyarrhyhtmia, and palliative balloon pericardiotomy are becoming more and more established. These alternative interventional methods are attractive, because no postsurgical pain and no complications potentially associated with thoracotomy ensue. The knowledge of such new treatment modalities and particularly the indications for an intervention are prerequisites to apply them optimally and broadly.

  9. Left Ventricular Synchrony and Function in Pediatric Patients with Definitive Pacemakers

    Science.gov (United States)

    Ortega, Michel Cabrera; Morejón, Adel Eladio Gonzales; Ricardo, Giselle Serrano

    2013-01-01

    Background Chronic right ventricular pacing (RVP) induces a dyssynchronous contraction pattern, producing interventricular and intraventricular asynchrony. Many studies have shown the relationship of RVP with impaired left ventricular (LV) form and function. Objective The aim of this study was to evaluate LV synchrony and function in pediatric patients receiving RVP in comparison with those receiving LV pacing (LVP). Methods LV systolic and diastolic function and synchrony were evaluated in 80 pediatric patients with either nonsurgical or postsurgical complete atrioventricular block, with pacing from either the RV endocardium (n = 40) or the LV epicardium (n = 40). Echocardiographic data obtained before pacemaker implantation, immediately after it, and at the end of a mean follow-up of 6.8 years were analyzed. Results LV diastolic function did not change in any patient during follow-up. LV systolic function was preserved in patients with LVP. However, in children with RVP the shortening fraction and ejection fraction decreased from medians of 41% ± 2.6% and 70% ± 6.9% before implantation to 32% ± 4.2% and 64% ± 2.5% (p < 0.0001 and p < 0.0001), respectively, at final follow-up. Interventricular mechanical delay was significantly larger with RVP (66 ± 13 ms) than with LVP (20 ± 8 ms). Similarly, the following parameters were significantly different in the two groups: LV mechanical delay (RVP: 69 ± 6 ms, LVP: 30 ± 11 ms, p < 0.0001); septal to lateral wall motion delay (RVP: 75 ± 19 ms, LVP: 42 ± 10 ms, p < 0.0001); and, septal to posterior wall motion delay (RVP: 127 ± 33 ms, LVP: 58 ± 17 ms, p < 0.0001). Conclusion Compared with RV endocardium, LV epicardium is an optimal site for pacing to preserve cardiac synchrony and function. PMID:24061683

  10. Thin-film rechargeable lithium batteries for implantable devices

    Energy Technology Data Exchange (ETDEWEB)

    Bates, J.b.; Dudney, N.J.

    1997-05-01

    Thin films of LiCoO{sub 2} have been synthesized in which the strongest x-ray reflection is either weak or missing, indicating a high degree of preferred orientation. Thin-film solid state batteries with these textured cathode films can deliver practical capacities at high current densities. For example, for one of the cells 70% of the maximum capacity between 4.2 V and 3 V ({approximately}0.2 mAh/cm{sup 2}) was delivered at a current of 2 mA/cm{sup 2}. When cycled at rates of 0.1 mA/cm{sup 2}, the capacity loss was 0.001 %/cycle or less. The reliability and performance of Li-LiCoO{sub 2} thin-film batteries make them attractive for application in implantable devices such as neural stimulators, pacemakers, and defibrillators.

  11. Thin-film Rechargeable Lithium Batteries for Implantable Devices

    Science.gov (United States)

    Bates, J. B.; Dudney, N. J.

    1997-05-01

    Thin films of LiCoO{sub 2} have been synthesized in which the strongest x ray reflection is either weak or missing, indicating a high degree of preferred orientation. Thin film solid state batteries with these textured cathode films can deliver practical capacities at high current densities. For example, for one of the cells 70% of the maximum capacity between 4.2 V and 3 V ({approximately}0.2 mAh/cm{sup 2}) was delivered at a current of 2 mA/cm{sup 2}. When cycled at rates of 0.1 mA/cm{sup 2}, the capacity loss was 0.001%/cycle or less. The reliability and performance of Li LiCoO{sub 2} thin film batteries make them attractive for application in implantable devices such as neural stimulators, pacemakers, and defibrillators.

  12. Cardiac echinococcosis

    Directory of Open Access Journals (Sweden)

    Ivanović-Krstić Branislava A.

    2002-01-01

    Full Text Available Cardiac hydatid disease is rare. We report on an uncommon hydatid cyst localized in the right ventricular wall, right atrial wall tricuspid valve left atrium and pericard. A 33-year-old woman was treated for cough, fever and chest pain. Cardiac echocardiograpic examination revealed a round tumor (5.8 x 4 cm in the right ventricular free wall and two smaller cysts behind that tumor. There were cysts in right atrial wall and tricuspidal valve as well. Serologic tests for hydatidosis were positive. Computed tomography finding was consistent with diagnosis of hydatid cyst in lungs and right hylar part. Surgical treatment was rejected due to great risk of cardiac perforation. Medical treatment with albendazole was unsuccessful and the patient died due to systemic hydatid involvement of the lungs, liver and central nervous system.

  13. Nonlinear oscillations in a muscle pacemaker cell model

    Science.gov (United States)

    González-Miranda, J. M.

    2017-02-01

    This article presents a numerical simulation study of the nonlinear oscillations displayed by the Morris-Lecar model [Biophys. J. 35 (1981) 193] for the oscillations experimentally observed in the transmembrane potential of a muscle fiber subject to an external electrical stimulus. We consider the model in the case when there is no external stimulation, aiming to establish the ability of the model to display biophysically reasonable pacemaker dynamics. We obtain 2D bifurcation diagrams showing that indeed the model presents oscillatory dynamics, displaying the two main types of action potentials that are observed in muscle fibers. The results obtained are shown to be structurally stable; that is, robust against changes in the values of system parameters. Moreover, it is demonstrated how the model is appropriate to analyze the action potentials observed in terms of the transmembrane currents creating them.

  14. The Immunoendocrine Thymus as a Pacemaker of Lifespan.

    Science.gov (United States)

    Csaba, György

    2016-06-01

    The thymus develops from an endocrine area of the foregut, and retains the ancient potencies of this region. However, later it is populated by bone marrow originated lymphatic elements and forms a combined organ, which is a central part of the immune system as well as an influential element of the endocrine orchestra. Thymus produces self-hormones (thymulin, thymosin, thymopentin, and thymus humoral factor), which are participating in the regulation of immune cell transformation and selection, and also synthesizes hormones similar to that of the other endocrine glands such as melatonin, neuropeptides, and insulin, which are transported by the immune cells to the sites of requests (packed transport). Thymic (epithelial and immune) cells also have receptors for hormones which regulate them. This combined organ, which is continuously changing from birth to senescence seems to be a pacemaker of life. This function is basically regulated by the selection of self-responsive thymocytes as their complete destruction helps the development (up to puberty) and their gradual release in case of weakened control (after puberty) causes the erosion of cells and intercellular material, named aging. This means that during aging, self-destructive and non-protective immune activities are manifested under the guidance of the involuting thymus, causing the continuous irritation of cells and organs. Possibly the pineal body is the main regulator of the pacemaker, the neonatal removal of which results in atrophy of thymus and wasting disease and its later corrosion causes the insufficiency of thymus. The co-involution of pineal and thymus could determine the aging and the time of death without external intervention; however, external factors can negatively influence both of them.

  15. Are patients with cardiac implants protected against electromagnetic interference in daily life and occupational environment?

    Science.gov (United States)

    Napp, Andreas; Stunder, Dominik; Maytin, Melanie; Kraus, Thomas; Marx, Nikolaus; Driessen, Sarah

    2015-07-21

    Utilization of cardiac implants such as pacemakers and implantable cardioverter defibrillators is now commonplace among heart disease patients. The ever-increasing technological complexity of these devices is matched by the near omnipresent exposure to electric, magnetic, and electromagnetic fields (EMFs), both in everyday life and the occupational environment. Given that electromagnetic interferences (EMIs) are associated with potential risk in device patients, physicians are increasingly confronted with managing device patients with intermittent EMI and chronic occupational exposure. The current review aims to provide a contemporary overview of cardiovascular implantable electronic devices, their function and susceptibility of non-medical EMFs and provide recommendations for physicians caring for cardiac device patients presenting with EMI.

  16. Modeling cardiac mechano-electrical feedback using reaction-diffusion-mechanics systems

    Science.gov (United States)

    Keldermann, R. H.; Nash, M. P.; Panfilov, A. V.

    2009-06-01

    In many practically important cases, wave propagation described by the reaction-diffusion equation initiates deformation of the medium. Mathematically, such processes are described by coupled reaction-diffusion-mechanics (RDM) systems. RDM systems were recently used to study the effects of deformation on wave propagation in cardiac tissue, so called mechano-electrical feedback (MEF). In this article, we review the results of some of these studies, in particular those relating to the effects of deformation on pacemaker activity and spiral wave dynamics in the heart. We also provide brief descriptions of the numerical methods used, and the underlying cardiac physiology.

  17. Pacing to treat low cardiac output syndrome following elective aortic valve replacement

    Directory of Open Access Journals (Sweden)

    Muhammad Ishaq

    2012-01-01

    Full Text Available We report a case of low cardiac output syndrome caused by dynamic left ventricular (LV outflow obstruction after aortic valve replacement (AVR. This recognized phenomenon probably occurs more frequently than appreciated, and the author suggests that this should be considered when managing patients with severe hemodynamic instability after AVR. In addition, we also focus on the fact that invasive pacemaker systems have significant effects on cardiac output augmentation postoperatively and in long-term management of patients with LV outflow tract (LVOT obstruction following AVR. The possible mechanisms and subsequent treatments are discussed.

  18. Hyperpolarization-Activated Current, , in Mathematical Models of Rabbit Sinoatrial Node Pacemaker Cells

    Directory of Open Access Journals (Sweden)

    Arie O. Verkerk

    2013-01-01

    Full Text Available A typical feature of sinoatrial (SA node pacemaker cells is the presence of an ionic current that activates upon hyperpolarization. The role of this hyperpolarization-activated current, , which is also known as the “funny current” or “pacemaker current,” in the spontaneous pacemaker activity of SA nodal cells remains a matter of intense debate. Whereas some conclude that plays a fundamental role in the generation of pacemaker activity and its rate control, others conclude that the role of is limited to a modest contribution to rate control. The ongoing debate is often accompanied with arguments from computer simulations, either to support one's personal view or to invalidate that of the antagonist. In the present paper, we review the various mathematical descriptions of that have been used in computer simulations and compare their strikingly different characteristics with our experimental data. We identify caveats and propose a novel model for based on our experimental data.

  19. Psychosocial aspects and mental health in children after permanent pacemaker implantation

    DEFF Research Database (Denmark)

    Andersen, C; Hørder, K; Kristensen, L

    1994-01-01

    The present study was designed to evaluate the psychosocial status and the mental health of children receiving a permanent pacemaker during childhood. Nineteen children under the age of 19 years had a permanent pacemaker implanted. Contact was established to 15 of these patients, 7 girls and 8 boys......, and they were given a child-psychiatric evaluation consisting of a semi-structured and a child-psychiatric interview. The psychological interview used intelligence tests and the Draw-A-Person test as well as the Rorschach test. The patients had had their pacemakers during an average of 6.7 years (range 3......-14). Generally the psychological condition was strained in 7 families, in which psychiatric and social therapy had been necessary. The children's intelligence was within normal ranges, average IQ being 110 (range 80-135). The children had abnormal body image related to the pacemaker. Adults virtually incorporate...

  20. Cardiac Rehabilitation

    Science.gov (United States)

    ... your risk of future heart problems, and to improve your health and quality of life. Cardiac rehabilitation programs increase ... exercise routine at home or at a local gym. You may also continue to ... health concerns. Education about nutrition, lifestyle and weight loss ...

  1. Involvement of mitochondrial Na+-Ca2+ exchange in intestinal pacemaking activity

    Institute of Scientific and Technical Information of China (English)

    Byung Joo Kim; Jae Yeoul Jun; Insuk So; Ki Whan Kim

    2006-01-01

    AIM: Interstitial cells of Cajal (ICCs) are the pacemaker cells that generate slow waves in the gastrointestinal (GI) tract. We have aimed to investigate the involvement of mitochondrial Na+-Ca2+ exchange in intestinal pacemaking activity in cultured interstitial cells of Cajal.METHODS: Enzymatic digestions were used todissociate ICCs from the small intestine of a mouse. The whole-cell patch-clamp configuration was used to record membrane currents (voltage clamp) and potentials (current clamp) from cultured ICCs.RESULTS: Clonazepam and CGP37157 inhibited the pacemaking activity of ICCs in a dose-dependent manner.Clonazepam from 20 to 60 μmol/L and CGP37157 from 10 to 30 μmol/L effectively inhibited Ca2+ efflux from mitochondria in pacemaking activity of ICCs. The IC50S of clonazepam and CGP37157 were 37.1 and 18.2 μmol/L, respectively. The addition of 20 μmol/L NiCl2 to the internal solution caused a "wax and wane" phenomenon of pacemaking activity of ICCs.CONCLUSION: These results suggest that mitochondrial Na+-Ca2+ exchange has an important role in intestinal pacemaking activity.

  2. Irregular excitation patterns in reaction-diffusion systems due to perturbation by secondary pacemakers.

    Science.gov (United States)

    Lenk, Claudia; Einax, Mario; Maass, Philipp

    2013-04-01

    Spatiotemporal excitation patterns in the FitzHugh-Nagumo model are studied, which result from the disturbance of a primary pacemaker by a secondary pacemaker. The primary and secondary pacemakers generate regular waves with frequencies f(pace) and f(pert), respectively. The pacemakers are spatially separated, but waves emanating from them encounter each other via a small bridge. This leads to three different types I-III of irregular excitation patterns in disjunct domains of the f(pace)-f(pert) plane. Types I and II are caused by detachments of waves coming from the two pacemakers at corners of the bridge. Type III irregularities are confined to a boundary region of the system and originate from a partial penetration of the primary waves into a space, where circular wave fronts from the secondary pacemaker prevail. For this type, local frequencies can significantly exceed f(pace) and f(pert). The degree of irregularity found for the three different types is quantified by the entropy of the local frequency distribution and an order parameter for phase coherence.

  3. Frequency of cardiac arrhythmias in high and low- yielding dairy cows

    Directory of Open Access Journals (Sweden)

    Afshin Jafari Dehkordi

    2014-06-01

    Full Text Available Electrocardiography (ECG may be used to recognize cardiac disorders. Levels of milk production may change the serum electrolytes which its imbalance has a role in cardiac arrhythmia. Fifty high yielding and fifty low yielding Holstein dairy cows were used in this study. Electrocardiography was recorded by base-apex lead and blood samples were collected from jugular vein for measurement of serum elements such as sodium, potassium, calcium, phosphorous, iron and magnesium. Cardiac dysrhythmias were detected more frequent in low yielding Holstein cows (62.00% compared to high yielding Holstein cows (46.00%. The cardiac dysrhythmias that were observed in low yielding Holstein cows included sinus arrhythmia (34.70%, wandering pacemaker (22.45 %, bradycardia (18.37%, tachycardia (10.20%, atrial premature beat (2.04%, sinoatrial block (2.04%, atrial fibrillation (8.16% and atrial tachycardia (2.04%. The cardiac dysrhythmias were observed in high yielding Holstein cows including, sinus arrhythmia (86.95% and wandering pacemaker (13.05%. Also, notched P wave was observed to be 30% and 14% in high- and low- yielding Holstein cows respectively. The serum calcium concentration of low yielding Holstein cows was significantly lower than that of high yielding Holstein cows. There was not any detectable significant difference in other serum elements between high- and low- yielding Holstein cows. Based on the result of present study, could be concluded that low serum concentration of calcium results to more frequent dysrhythmias in low yielding Holstein cows.

  4. Effects of thallium on membrane currents at diastolic potentials in canine cardiac Purkinje strands.

    Science.gov (United States)

    Cohen, I S; Mulrine, N K

    1986-01-01

    A two-micro-electrode voltage-clamp technique was used to record membrane currents from canine cardiac Purkinje strands during hyperpolarizing steps to potentials between -70 and -150 mV in Tyrode solutions containing K+ and/or Tl+. Complete replacement of external K+ by equimolar Tl+ increases the instantaneous inwardly rectifying current. The inwardly rectifying region of the instantaneous I-V relation is shifted to more positive potentials and its slope is increased. The diastolic time-dependent current is reduced or reversed. Partial substitution of equimolar Tl+ for K+ reduces the diastolic time-dependent current. The instantaneous I-V relation is shifted inward for molar fractions of Tl+ (YTl) greater than 0.5, and is slightly more inward or unchanged for YTl less than or equal to 0.5. Addition of small amounts of Tl+ shifts the instantaneous I-V relation inward and reduces the diastolic time-dependent current. Addition of Tl+ in solutions containing Ba2+ to block the background inward rectifier has no effect on the instantaneous I-V relation; the diastolic time-dependent (pace-maker) current is reduced. Block of the pace-maker current by Tl+ is largely independent of potential in Ba2+ Tyrode solution. Since Tl+ has opposite effects on the pace-maker current and the inward rectifier, these findings support other evidence that the pace-maker current is not part of the background inward rectifier.

  5. Use of an active fixation lead and a subpectoral pacemaker pocket may not avoid Twiddler′s syndrome

    Directory of Open Access Journals (Sweden)

    Floris E A Udink ten Cate

    2012-01-01

    Full Text Available Manipulation of a pacemaker with consequent malfunction of the device has been called Twiddler′s syndrome. Use of active-fixation leads and subpectoral pacemaker pockets has been considered to help in avoiding this problem. We describe a child in whom twiddling was not prevented despite implantation of a lumenless atrial lead and insertion of the pacemaker generator in a subpectoral pocket.

  6. Propagation of pacemaker activity in the guinea-pig antrum.

    Science.gov (United States)

    Hennig, G W; Hirst, G D S; Park, K J; Smith, C B; Sanders, K M; Ward, S M; Smith, T K

    2004-04-15

    Cyclical periods of depolarization (slow waves) underlie peristaltic contractions involved in mixing and emptying of contents in the gastric antrum. Slow waves originate from a myenteric network of interstitial cells of Cajal (ICC-MY). In this study we have visualized the sequence and propagation of Ca(2+) transients associated with pacemaker potentials in the ICC network and longitudinal (LM) and circular muscle (CM) layers of the isolated guinea-pig gastric antrum. Gastric antrum was dissected to reveal the ICC-MY network, loaded with Fluo-4 AM and activity was monitored at 37 degrees C. Ca(2+) waves propagated throughout the ICC-MY network at an average velocity of 3.24 +/- 0.12 mm s(-1) at a frequency of 4.87 +/- 0.16 cycles min(-1) (n= 4). The propagation of the Ca(2+) wave often appeared 'step-like', with separate regions of the network being activated after variable delays. The direction of propagation was highly variable (Delta angle of propagation 44.3 +/- 10.9 deg per cycle) and was not confined to the axes of the longitudinal or circular muscle. Ca(2+) waves appeared to spread out radially from the site of initiation. The initiating Ca(2+) wave in ICC-MY was correlated to secondary Ca(2+) waves in intramuscular interstitial cells of Cajal, ICC-IM, and smooth muscle cells, and the local distortion (contraction) in a field of view. TTX (1 microm) had little effect on slow wave or pacemaker potential activity, but 2-APB (50 microm) blocked all Ca(2+) waves, indicating a pivotal role for intracellular Ca(2+) stores. Nicardipine (2 microm) eliminated the Ca(2+) transient generated by smooth muscle, but did not affect the fast upstroke associated with ICC-MY. These results indicate that slow waves follow a sequence of activation, beginning with the ICC-MY and ICC-IM network, followed later by a sustained Ca(2+) transient in the muscle layers that is responsible for contraction.

  7. Cardiac Calcification

    Directory of Open Access Journals (Sweden)

    Morteza Joorabian

    2011-05-01

    Full Text Available There is a spectrum of different types of cardiac"ncalcifications with the importance and significance"nof each type of cardiac calcification, especially"ncoronary artery calcification. Radiologic detection of"ncalcifications within the heart is quite common. The"namount of coronary artery calcification correlates"nwith the severity of coronary artery disease (CAD."nCalcification of the aortic or mitral valve may indicate"nhemodynamically significant valvular stenosis."nMyocardial calcification is a sign of prior infarction,"nwhile pericardial calcification is strongly associated"nwith constrictive pericarditis. A spectrum of different"ntypes of cardiac calcifications (linear, annular,"ncurvilinear,... could be seen in chest radiography and"nother imaging modalities. So a carful inspection for"ndetection and reorganization of these calcifications"nshould be necessary. Numerous modalities exist for"nidentifying coronary calcification, including plain"nradiography, fluoroscopy, intravascular ultrasound,"nMRI, echocardiography, and conventional, helical and"nelectron-beam CT (EBCT. Coronary calcifications"ndetected on EBCT or helical CT can be quantifie,"nand a total calcification score (Cardiac Calcification"nScoring may be calculated. In an asymptomatic"npopulation and/or patients with concomitant risk"nfactors like diabetes mellitus, determination of the"npresence of coronary calcifications identifies the"npatients at risk for future myocardial infarction and"ncoronary artery disease. In patients without coronary"ncalcifications, future cardiovascular events could"nbe excluded. Therefore, detecting and recognizing"ncalcification related to the heart on chest radiography"nand other imaging modalities such as fluoroscopy, CT"nand echocardiography may have important clinical"nimplications.

  8. Risk of pacemaker implantation subsequent to radiotherapy for early-stage breast cancer in Denmark, 1982-2005

    DEFF Research Database (Denmark)

    Rehammar, Jens Christian; Videbaek, L.; Brock Johansen, J.

    2015-01-01

    -stage breast cancer in Denmark from 1982 to 2005. By record linkage to the Danish Pacemaker and ICD Registry information was retrieved on pacemaker implants subsequent to radiotherapy. Rate ratios (RR) of pacemaker implantation for left versus right sided breast cancer were calculated. Results: Among 18......,308 women treated with radiotherapy for early-stage breast cancer, 179 women had a pacemaker implanted subsequent to radiotherapy, 90 in 9,315 left sided and 89 in 8,993 right sided breast cancers. The unadjusted RR was 1.02 (0.76-1.36 95% CI, p=0.91) and the RR adjusted for year, age and time since...

  9. Phentolamine inhibits the pacemaker activity of mouse interstitial cells of Cajal by activating ATP-sensitive K+ channels.

    Science.gov (United States)

    Ahn, Seung Whan; Kim, Sang Hun; Kim, Jin Ho; Choi, Seok; Yeum, Cheol Ho; Wie, Hee Wook; Sun, Jae Myeong; So, Insuk; Jun, Jae Yeoul

    2010-03-01

    The aim of this study was to clarify if phentolamine has proven effects on the pacemaker activities of interstitial cells of Cajal (ICC) from the mouse small intestine involving the ATPsensitive K(+) channels and adrenergic receptor. The actions of phentolamine on pacemaker activities were investigated using whole-cell patch-clamp technique and intracellular Ca(2+) analysis at 30 degrees C in cultured mouse intestinal ICC. ICC generated spontaneous pacemaker currents at a holding potential of -70 mV. Treatment with phentolamine reduced the frequency and amplitude of the pacemaker currents and increased the resting outward currents. Moreover, under current clamping (I = 0), phentolamine hyperpolarized the ICC membrane and decreased the amplitude of the pacemaker potentials. We also observed that phentolamine inhibited spontaneous [Ca(2+)](i) oscillations in ICC. The alpha-adrenergic drugs prazosin, yohimbine, methoxamine, and clonidine had no effect on ICC intestinal pacemaker activity and did not block phentolamine-induced effects. Phentolamine-induced effects on the pacemaker currents and the pacemaker potentials were significantly inhibited by ATP sensitive K(+) channel blocker glibenclamide, but not by TEA, apamin, or 4-aminopyridine. In addition, the NO synthase inhibitor, L-NAME and the guanylate cyclase inhibitor, ODQ were incapable of blocking the phentolamine-induced effects. These results demonstrate that phentolamine regulates the pacemaker activity of ICC via ATP-sensitive K(+) channel activation. Phentolamine could act through an adrenergic receptor- and also through NO-independent mechanism that involves intracellular Ca(2+) signaling.

  10. Quasiperiodicity route to chaos in cardiac conduction model

    Science.gov (United States)

    Quiroz-Juárez, M. A.; Vázquez-Medina, R.; Ryzhii, E.; Ryzhii, M.; Aragón, J. L.

    2017-01-01

    It has been suggested that cardiac arrhythmias are instances of chaos. In particular that the ventricular fibrillation is a form of spatio-temporal chaos that arises from normal rhythm through a quasi-periodicity or Ruelle-Takens-Newhouse route to chaos. In this work, we modify the heterogeneous oscillator model of cardiac conduction system proposed in Ref. [Ryzhii E, Ryzhii M. A heterogeneous coupled oscillator model for simulation of ECG signals. Comput Meth Prog Bio 2014;117(1):40-49. doi:10.1016/j.cmpb.2014.04.009.], by including an ectopic pacemaker that stimulates the ventricular muscle to model arrhythmias. With this modification, the transition from normal rhythm to ventricular fibrillation is controlled by a single parameter. We show that this transition follows the so-called torus of quasi-periodic route to chaos, as verified by using numerical tools such as power spectrum and largest Lyapunov exponent.

  11. [Antibiotics and artificial nutrition in the cardiac intensive care unit].

    Science.gov (United States)

    De Gaudio, Raffaele; Selmi, Valentina; Chelazzi, Cosimo

    2010-04-01

    Patients admitted to cardiac intensive care units are at high risk for infections, particularly nosocomial pneumonia, pacemaker's pocket and sternotomic wound infections. These complications delay recovery, prolong hospitalization, time on mechanical ventilation, and increase mortality. Both behavioral and pharmacological measures are needed to prevent and control infections in these patients, as well as specific antibiotic treatment and nutritional support. In infected critically ill patients, pathophysiological alterations modify distribution and clearance of antibiotics, and hypercatabolic state leads to malnutrition and immune paralysis, which both contribute to increased infectious risk and worsened outcome. A deep understanding of antibacterial agents pharmacology in the critically ill is essential in order to treat severe infections; moreover, it is necessary to know routes of administration and composition of artificial nutrition solutions. The aim of this review is to define main and specific aspects of antibiotic therapy and nutritional support in cardiac critical care patients in light of recent literature data.

  12. Clinical applications of magnets on cardiac rhythm management devices.

    Science.gov (United States)

    Jacob, Sony; Panaich, Sidakpal S; Maheshwari, Rahul; Haddad, John W; Padanilam, Benzy J; John, Sinoj K

    2011-09-01

    The growing indications for permanent pacemaker and implantable cardioverter defibrillator (ICD) implantation have increased the number of patients with these cardiac rhythm management devices (CRMDs). Cardiac rhythm management devices occasionally perform inappropriately in response to electromagnetic interference (e.g. surgical electrocautery) or lead noise over-sensing (e.g. lead fracture). Temporary reprogramming of the CRMDs using device programmers can prevent these untoward device responses. However, these programmers are device manufacturer specific and require technically qualified personnel to operate. This could cause delayed patient care and increased use of resources in certain clinical situations. Alternatively, clinical magnets, when appropriately positioned over the device site, can change the pacing to an asynchronous mode in pacemakers and suspend tachycardia therapies in ICDs. Although readily available, clinical magnets have not been widely used for this purpose, perhaps due to the unfamiliarity with the variable responses of CRMDs to magnet application. This article provides a comprehensive overview of the current literature on the mechanism of action and the specific responses of various CRMDs to clinical magnets.

  13. Alkaline battery operational methodology

    Science.gov (United States)

    Sholklapper, Tal; Gallaway, Joshua; Steingart, Daniel; Ingale, Nilesh; Nyce, Michael

    2016-08-16

    Methods of using specific operational charge and discharge parameters to extend the life of alkaline batteries are disclosed. The methods can be used with any commercial primary or secondary alkaline battery, as well as with newer alkaline battery designs, including batteries with flowing electrolyte. The methods include cycling batteries within a narrow operating voltage window, with minimum and maximum cut-off voltages that are set based on battery characteristics and environmental conditions. The narrow voltage window decreases available capacity but allows the batteries to be cycled for hundreds or thousands of times.

  14. 体外无创临时心脏起搏的应用体会%In vitro noninvasive application of temporary pacemaker

    Institute of Scientific and Technical Information of China (English)

    刘志成; 宋秀梅

    2014-01-01

    目的:评价在急诊抢救时对心脏骤停及严重缓慢性心律失常实施体外无创性临时心脏起搏的临床效果。方法对2008年1月-2013年12月在我急诊科抢救的83例心脏骤停患者、45例缓慢性心律失常患者根据当时疾病的严重程度及不同医生的治疗观点分为二组:A 组:实施体外无创性临时心脏起搏结合药物治疗;B 组:常规药物治疗。治疗期间严密观察心电监护,心跳,血压,统计比较两组恢复正常心跳的成功率。结果通过临床观察对比统计,A 组:心脏骤停及缓慢性心律失常病例中恢复心跳分别为36例(85.7%)和23例(100%)。B 组:心脏骤停及缓慢性心律失常病例中恢复心跳分别为23例(56.1%)和15例(68.1%)。A 组恢复正常心跳成功率较 B 组高。结论在急诊抢救领域中对心脏骤停及严重缓慢性心律失常患者实施体外起搏的临床疗效较好,抢救成功率高,并且使用安全、简便、快捷是治疗缓慢性心律失常、预防和抢救心脏骤停的好手段,值得在临床急救推广使用。%Objective To evaluate clinic effect in the emergency rescue of sudden cardiac arrest and severe tardy ar-rhythmia in vitro noninvasive temporary cardiac pacemaker. Methods January 2008 -December 201 3 in emergency rescue of 83 patients with cardiac arrest,45 cases of tardy arrhythmia patients were divided into two groups:Group A:In vitro non-inva-sive temporary pacemaker combined with drug therapy;Group B:Routine drug therapy.Closely observe the ECG monitoring dur-ing treatment,heart rate,blood pressure,statistical comparison of two groups of normal heart rate. Results By compared with clinical observation statistics,Group A:36 cases was cardiac arrest and tardy arrhythmia cases heart back,85.7%,and 23 cases was accounting for 1 00%.Group B:Cardiac arrest and tardy arrhythmia cases to restore the heart of 23 cases accounting was for 56.1 % and 1

  15. Nonlinear dynamics of the heartbeat II. Subharmonic bifurcations of the cardiac interbeat interval in sinus node disease

    Science.gov (United States)

    Goldberger, Ary L.; Bhargava, Valmik; West, Bruce J.; Mandell, Arnold J.

    1985-10-01

    Changing the coupling of electronic relaxation oscillators may be associated with the emergence of complex periodic behavior. The electrocardiographic record of a patient with the “sick sinus syndrome” demonstrated periodic behavior including subharmonic bifurcations in an attractor of his interbeat interval. Such nonlinear dynamics which may emerge from alterations in the coupling of oscillating pacemakers are not predicted by traditional models in cardiac electrophysiology. An understanding of the nonlinear behavior of physical and mathematical systems may generalize to pathophysiological processes.

  16. Distribution of pacemaker function through the tunica muscularis of the canine gastric antrum.

    Science.gov (United States)

    Horiguchi, K; Semple, G S; Sanders, K M; Ward, S M

    2001-11-15

    1. Interstitial cells of Cajal (ICC) have been shown to generate pacemaker activity in gastrointestinal (GI) muscles. Experiments were performed to characterize the ICC within the canine gastric antrum and to determine the site(s) of pacemaker activity and whether active propagation pathways exist within the thick-walled tunica muscularis of large mammals. 2. Immunohistochemistry and electron microscopy revealed four populations of ICC within the antral muscularis on the basis of anatomical location. Typical ICC were found in the myenteric region of the small intestine (IC-MY). Intramuscular ICC (IC-IM) were intermingled between muscle fibres of circular and longitudinal muscle layers. ICC were also found within septa (IC-SEP) between muscle bundles and along the submucosal surface of the circular muscle layer (IC-SM). ICC were identified in each location by ultrastructural features. 3. Intracellular electrical recordings demonstrated nifedipine-insensitive slow waves throughout the circular muscle layer. Separation of interior and submucosal circular muscle strips from the dominant (myenteric) pacemaker region dramatically slowed frequency but did not block spontaneous slow waves, suggesting that pacemaker cells populate all regions of the circular muscle. 4. Slow waves could be evoked in interior and submucosal circular muscles at rates above normal antral frequency by electrical pacing or by acetylcholine (0.3 microM). Active slow wave propagation occurred in all regions of the circular muscle, and propagation velocities were similar in each region. 5. In summary, antral muscles of the canine stomach have pacemaker capability throughout the circular muscle. Normally, a dominant pacemaker near the myenteric plexus drives slow waves that actively propagate throughout the circular layer. Pacemaker activity and the active propagation pathway may occur in networks of ICC that are distributed in the region of the myenteric plexus and throughout the circular muscle

  17. [Successful mitral valve replacement in a patient with functional mitral regurgitation induced by cardiac sarcoidosis;report of a case].

    Science.gov (United States)

    Sato, Ken; Takazawa, Ippei; Aizawa, Kei; Misawa, Yoshio

    2015-03-01

    We report a case of cardiac sarcoidosis associated with mitral valve regurgitation. A 62-year-old woman with cardiac sarcoidosis was admitted for the treatment of an intractable mitral regurgitation. She had been treated for cardiac sarcoidosis with prednisolone, and she had undergone pacemaker implantation because of advanced complete A-V block 5 years before. However, her hemodynamics deteriorated, and echocardiography revealed severe functional mitral regurgitation, thinning of the ventricular septum, and left ventricular dysfunction. The patient underwent mitral valve replacement with a mechanical prosthetic valve, and her postoperative course was uneventful. She is currently well without exacerbation of heart failure at 2 years after operation. Functional mitral regurgitation is a relatively common complication in patients with cardiac sarcoidosis. Mitral valve replacement should be considered in patients with medically intractable mitral valve dysfunction due to cardiac sarcoidosis.

  18. Rescue of a trafficking defective human pacemaker channel via a novel mechanism: roles of Src, Fyn, and Yes tyrosine kinases.

    Science.gov (United States)

    Lin, Yen-Chang; Huang, Jianying; Kan, Hong; Frisbee, Jefferson C; Yu, Han-Gang

    2009-10-30

    Therapeutic strategies such as using channel blockers and reducing culture temperature have been used to rescue some long QT-associated voltage-gated potassium Kv trafficking defective mutant channels. A hyperpolarization-activated cyclic nucleotide-gated HCN4 pacemaker channel mutant (D553N) has been recently found in a patient associated with cardiac arrhythmias including long QT. D553N showed the defective trafficking to the cell surface, leading to little ionic current expression (loss-of-function). We show in this report that enhanced tyrosine phosphorylation mediated by Src, Fyn, and Yes kinases was able to restore the surface expression of D553N for normal current expression. Src or Yes, but not Fyn, significantly increased the current density and surface expression of D553N. Fyn accelerated the activation kinetics of the rescued D553N. Co-expression of D553N with Yes exhibited the slowest activation kinetics of D553N. Src, Fyn, and Yes significantly enhanced the tyrosine phosphorylation of D553N. A combination of Src, Fyn, and Yes rescued the current expression and the gating of D553N comparable with those of wild-type HCN4. In conclusion, we demonstrate a novel mechanism using three endogenous Src kinases to rescue a trafficking defective HCN4 mutant channel (D553N) by enhancing the tyrosine phosphorylation of the mutant channel protein.

  19. Effects of extracellular potassium on ventricular automaticity and evidence for a pacemaker current in mammalian ventricular myocardium.

    Science.gov (United States)

    Katzung, B G; Morgenstern, J A

    1977-01-01

    Automaticity was induced in isolated guinea pig and cat papillary muscles by application of depolarizing constant current pulses. Increasing extracellular potassium from 1 to 15 mM caused a shift of pacemaker-like activity to less negative diastolic potentials and a decrease in maximum phase 4 slope. Membrane resistance, estimated from the relation of applied current to maximum diastolic potential, decreased when extracellular potassium was increased. Voltage clamps of cat papillary muscle demonstrated that action potentials activate a time-dependent outward current which has a reversal potential of -79.1 mV (+/- 0.99 SE, n = 20) at an extracellular potassium concentration of 5 mM. The reversal potential of this current varies with extracellular K+ with a slope of 50-60 mV per 10-fold concentration change. The current is activated by voltage clamps or action potential plateaus in the range of -30 to +30 mV. It has a time constant of deactivation which increases from approximately 100 to over 400 msec as clamp potential is increased from -90 to -60 mV. It is proposed that this current is equivalent to Ix1 demonstrated in other cardiac tissues and is responsible, in combination with inward currents, for automaticity in ventricular fibers.

  20. Caffeine increases light responsiveness of the mouse circadian pacemaker.

    Science.gov (United States)

    van Diepen, Hester C; Lucassen, Eliane A; Yasenkov, Roman; Groenen, Inske; Ijzerman, Adriaan P; Meijer, Johanna H; Deboer, Tom

    2014-11-01

    Caffeine is the most commonly used psychoactive stimulant worldwide. It reduces sleep and sleepiness by blocking access to the adenosine receptor. The level of adenosine increases during sleep deprivation, and is thought to induce sleepiness and initiate sleep. Light-induced phase shifts of the rest-activity circadian rhythms are mediated by light-responsive neurons of the suprachiasmatic nucleus (SCN) of the hypothalamus, where the circadian clock of mammals resides. Previous studies have shown that sleep deprivation reduces circadian clock phase-shifting capacity and decreases SCN neuronal activity. In addition, application of adenosine agonists and antagonists mimics and blocks, respectively, the effect of sleep deprivation on light-induced phase shifts in behaviour, suggesting a role for adenosine. In the present study, we examined the role of sleep deprivation in and the effect of caffeine on light responsiveness of the SCN. We performed in vivo electrical activity recordings of the SCN in freely moving mice, and showed that the sustained response to light of SCN neuronal activity was attenuated after 6 h of sleep deprivation prior to light exposure. Subsequent intraperitoneal application of caffeine was able to restore the response to light. Finally, we performed behavioural recordings in constant conditions, and found enhanced period lengthening during chronic treatment with caffeine in drinking water in constant light conditions. The data suggest that increased homeostatic sleep pressure changes circadian pacemaker functioning by reducing SCN neuronal responsiveness to light. The electrophysiological and behavioural data together provide evidence that caffeine enhances clock sensitivity to light.

  1. Pacemaker-Mediated Tachycardia: Manufacturer Specifics and Spectrum of Cases.

    Science.gov (United States)

    Monteil, Benjamin; Ploux, Sylvain; Eschalier, Romain; Ritter, Philippe; Haissaguerre, Michel; Koneru, Jayanthi N; Ellenbogen, Kenneth A; Bordachar, Pierre

    2015-12-01

    Pacemaker-mediated tachycardia (PMT) is the term used to describe a repetitive sequence of sensed retrograde P waves followed by ventricular pacing at or below the maximum tracking rate. The following events can promote atrioventricular (AV) dissociation, retrograde conduction, and the onset of PMT: ventricular or atrial extrasystole, an excessively long programmed AV delay, external interference or myopotentials sensed by the atrial channel, atrial sensing or pacing failure, the absence of postventricular atrial refractory period extension after removal of a magnet, and VDD pacing at a higher rate than sinus rate. In contemporary devices, each manufacturer has a proprietary algorithm to detect and terminate PMT. Because of the increase in the number and complexity of the pacing algorithms and because of manufacturer-driven differences, a basic understanding of these new algorithms is important for patient care. We review here the main elements of the physiopathology of this type of tachycardia, describe the specific characteristics of the different manufacturers, and present representative clinical cases.

  2. 9. Incidence of tricuspid valve regurgitation following pacemaker/defibrillator lead extraction

    Directory of Open Access Journals (Sweden)

    A. AlFagih

    2016-07-01

    .5% had pacing leads across the valve.Our study being a simple descriptive study could not find overwhelming evidence to support the claim that there is an elevated risk of new onset TR or deterioration of a regurgitant valve following pacemaker/defibrillator lead extraction. However, our study being a simple observational study with a considerably small sample size may influence the findings. Lack of appropriate control group in this study is a limitation in appraising the hypothesis. As there is scarcity of data in this important area of cardiac research, our findings should prompt motivation for larger and well controlled cohort studies.

  3. Analysis on clinical materials in patients with post-operation infection after implantation of permanent pacemaker%永久性心脏起搏器植入术后感染患者的临床资料分析

    Institute of Scientific and Technical Information of China (English)

    谭琛; 崔俊玉; 任晓庆; 李学斌; 胡雪红; 刘建国; 徐威; 李俊峡

    2013-01-01

    Objective To analyze retrospectively the clinical characteristics of the patients with post-operation infection after implantation of permanent pacemaker, and review different therapies. Methods The patients (n=12) with infection after implanting pacemakers (dual-chamber and three-chamber pacemaker) were chosen from Aug. 2005 to Mar. 2013. The clinical characteristics of the patients were analyzed, and different anti-infection therapies were compared (including antibiotics+local dressing change, antibiotics+debridement and sterilization of original pouch+transposition implantation of original-side pacemaker, and remove of pacemaker and lead+antibiotics+oppsite implantation of pacemaker). Results Among 12 patients, there were 11 (91.6%) with dual-chamber pacemaker and 1 (8.3%) with three-chamber pacemaker. The median of infection occurrence time was 4.5 months and follow-up time was (33.0±19.0) months. There were 10 (83.3%) complicated one or more other diseases (including diabetes, cardiac insufficiency, chronic obstructive pulmonary disease and connective tissue diseases), and 4 (33.3%) with two or more electrode leads. There were 8 cases with infection and recurrence from 10 (with expectant treatment firstly:antibiotics+local dressing change or antibiotics+debridement and sterilization of original pouch+transposition implantation of original-side pacemaker), among them, 6 were cured through whole pacemaker system, 1 was cured through pacemaker reimplantation after sterilization, and 1 had sinus tract and continues dressing change. There were 2 cases cured as they selected firstly to remove pacemaker system. Conclusion The infection of pacemaker commonly occurs in the patients with risk factors. To remove pacemaker system totally is reasonable when the infection involving the whole system.%目的回顾性分析永久性心脏起搏器植入术后感染患者的临床特点,并对不同治疗方法进行评价。方法纳入2005年8月~2013年3月植入心脏

  4. STEM promotion through museum exhibits on cardiac monitoring & cardiac rhythm management.

    Science.gov (United States)

    Countryman, Jordan D; Dow, Douglas E

    2014-01-01

    Formal education in science, technology, engineering and math (STEM) does not successfully engage all of the students who have potential to become skilled in STEM activities and careers. Museum exhibits may be able to reach and engage a broader range of the public. STEM Exhibits that are both understandable and capture the imagination of viewers may contribute toward increased interest in STEM activities. One such topic for such an exhibit could be cardiac pacemakers and cardioverter defibrillators that sustain life. Although museums have existed for centuries, the available types of exhibit designs has dramatically increased in recent decades due to innovations in technology. Science and technology museums have especially taken advantage of the progression of exhibit design to developed new ways to communicate to their viewers. These novel presentation tools allow museums to more effectively convey to and engage viewers. This paper examines the techniques employed by museums in exhibits and considers the practices of several museums with exhibits related to cardiac monitoring (CM) and cardiac rhythm management (CRM).

  5. Reexposure to nicotine during withdrawal increases the pacemaking activity of cholinergic habenular neurons

    Science.gov (United States)

    Görlich, Andreas; Antolin-Fontes, Beatriz; Ables, Jessica L.; Frahm, Silke; Ślimak, Marta A.; Dougherty, Joseph D.; Ibañez-Tallon, Inés

    2013-01-01

    The discovery of genetic variants in the cholinergic receptor nicotinic CHRNA5-CHRNA3-CHRNB4 gene cluster associated with heavy smoking and higher relapse risk has led to the identification of the midbrain habenula–interpeduncular axis as a critical relay circuit in the control of nicotine dependence. Although clear roles for α3, β4, and α5 receptors in nicotine aversion and withdrawal have been established, the cellular and molecular mechanisms that participate in signaling nicotine use and contribute to relapse have not been identified. Here, using translating ribosome affinity purification (TRAP) profiling, electrophysiology, and behavior, we demonstrate that cholinergic neurons, but not peptidergic neurons, of the medial habenula (MHb) display spontaneous tonic firing of 2–10 Hz generated by hyperpolarization-activated cyclic nucleotide-gated (HCN) pacemaker channels and that infusion of the HCN pacemaker antagonist ZD7288 in the habenula precipitates somatic and affective signs of withdrawal. Further, we show that a strong, α3β4-dependent increase in firing frequency is observed in these pacemaker neurons upon acute exposure to nicotine. No change in the basal or nicotine-induced firing was observed in cholinergic MHb neurons from mice chronically treated with nicotine. We observe, however, that, during withdrawal, reexposure to nicotine doubles the frequency of pacemaking activity in these neurons. These findings demonstrate that the pacemaking mechanism of cholinergic MHb neurons controls withdrawal, suggesting that the heightened nicotine sensitivity of these neurons during withdrawal may contribute to smoking relapse. PMID:24082085

  6. How to test mode switching in pacemakers implanted in patients: the MOST study.

    Science.gov (United States)

    Padeletti, Luigi; Gasparini, Maurizio; Porciani, Maria Cristina; Pieragnoli, Paolo; Colella, Andrea; Michelucci, Antonio; Proclemer, Alessandro; Tognarini, Stefano; Mantica, Massimo; Coltorti, Fernando; Corbucci, Giorgio; Sutton, Richard

    2002-02-01

    Optimal management of atrial arrhythmias with dual chamber pacemakers requires proper performance of automatic mode switching (AMS). The aim of this study was to develop a reliable technique to test the AMS function by using an external electronic device capable of mimicking the occurrence of supraventricular arrhythmias (Supraventricular Arrhythmia Simulator [SAS]). The SAS delivers low voltage pulse trains (200 mV, 20 ms) through two skin electrodes. Each pulse train lasts 15 seconds and starts synchronously with a pacing pulse of the implanted pacemaker to avoid interference from the operator. The pulse train rate is set at 350, 250, and 160 beats/min to simulate AF, atrial flutter, and atrial tachycardia (AT), respectively. Thirty-five patients implanted with Vitatron pacemakers, whose AMS system has been previously validated, were enrolled. Atrial and ventricular sensing were programmed in unipolar mode at 0.5 mV and in bipolar mode at > 2 mV, respectively. All pulses from the SAS were detected by the atrial channel at an amplitude ranging from 1 to 3 mV. The test proved to be safe and reliable at rest and during exercise. AMS occurred immediately at onset or at offset of atrial arrhythmias, and no adverse interference on pacemaker function was seen from the SAS. In conclusion, the described technique and the SAS are safe and reliable for patient and pacemaker function and can be proposed as a useful method to verify proper performance of AMS function irrespective of the type of implanted devices.

  7. Differences in atrial septal activation with an intrasinoatrial nodal pacemaker and epicardial sinoatrial nodal pacing.

    Science.gov (United States)

    Goldberg, J M

    1979-01-01

    Changes in Intra-SA nodal pacemaker localization were produced through stimulation of the decentralized cervical vagi and stellate ganglia in the anesthetized dog. Shifts in pacemaker to the rostral, middle, or caudal regions of the SA node produced a change in the timing as well as a change in the sequence of activation of recording sites overlying the AV node. Epicardial pacing with a plaque electrode from either the rostral, middle, or caudal regions of the SA node produced the same activation sequence of the AV nodal electrodes irrespective of the epicardial SA nodal pacing site. The inability of epicardial SA nodal pacing to precisely reproduce the activation pattern of the atrial septum overlying the AV node observed with a natural SA nodal pacemaker can be explained by the geographic relationship of the pacemaker cells within the node to the preferential internodal pathways and the area of atrial tissue stimulated by pacing. Pacing activates a large mass of tissue, whereas an intrinsic pacemaker probably acts as a more localized focus. The inability of pacing to reproduce the activation pattern seen with spontaneous rhythm may be a determinant in the varied P wave morphology seen with coronary sinus or AV nodal junctional rhythms, as compared with more consistent morphology seen with pacing.

  8. Permanent transvenous pacemaker implantation in a patient with Cor triatriatum dextrum

    Institute of Scientific and Technical Information of China (English)

    Kun; Xiang; George; V; Moukarbel; Blair; Grubb

    2015-01-01

    Cor triatriatum dextrum is an extremely rare congenital heart abnormality in which the right atrium is separatedinto two chambers by a persistent fibrous membrane. A transvenous approach to place a dual-chamber pacemaker in such patients is technically challenging. We report the first case of a transvenous permanent pacemaker placement in a patient with cor triatriatum dextrum. An 87-year-old woman was diagnosed with paroxysmal atrial fibrillation. She was accidentally found to have cor triatriatum dextrum during the transesophageal echocardiography(TEE) prior to cardioversion. Later during her hospital stay, it was indicated to place a permanant pacemaker due to high grade atrioventricular block. After thorough reviewing TEE imagings, a transvenous catheter-based approach was decided feasible. Patient successfully received a dual chamber pacemaker through left subclavian venous approach. Furthermore in our case, using specially designed pacemaker leads and cautious intra-procedural maneuvering under fluoroscopic guidance ensured procedural success. In summary, a thorough pre-operative evaluation with transesophageal echocardiography is critical for the planning and eventual success of the transvenous placement of rightsided leads.

  9. Optogenetics-enabled assessment of viral gene and cell therapy for restoration of cardiac excitability.

    Science.gov (United States)

    Ambrosi, Christina M; Boyle, Patrick M; Chen, Kay; Trayanova, Natalia A; Entcheva, Emilia

    2015-12-01

    Multiple cardiac pathologies are accompanied by loss of tissue excitability, which leads to a range of heart rhythm disorders (arrhythmias). In addition to electronic device therapy (i.e. implantable pacemakers and cardioverter/defibrillators), biological approaches have recently been explored to restore pacemaking ability and to correct conduction slowing in the heart by delivering excitatory ion channels or ion channel agonists. Using optogenetics as a tool to selectively interrogate only cells transduced to produce an exogenous excitatory ion current, we experimentally and computationally quantify the efficiency of such biological approaches in rescuing cardiac excitability as a function of the mode of application (viral gene delivery or cell delivery) and the geometry of the transduced region (focal or spatially-distributed). We demonstrate that for each configuration (delivery mode and spatial pattern), the optical energy needed to excite can be used to predict therapeutic efficiency of excitability restoration. Taken directly, these results can help guide optogenetic interventions for light-based control of cardiac excitation. More generally, our findings can help optimize gene therapy for restoration of cardiac excitability.

  10. Sugar for the fuel cell. Micro fuel cells for implants; Gib der Brennstoffzelle Zucker. Mikro-Brennstoffzellen fuer Implantate

    Energy Technology Data Exchange (ETDEWEB)

    Geitmann, Sven

    2012-04-15

    Scientists are working on micro fuel cells that will be capable of generating electric power from blood glucose. This may be an option for providing energy to cardiac pacemakers, hearing aids and other medical implants on a long-term basis. Surgery for battery exchange would be unnecessary, and patients would enjoy a better quality of life. In Germany, more than 70,000 cardiac pacemakers are implanted every year; batteries must be exchanged after about eight years. (orig.)

  11. Improved Cardiac Contractility of Human Recombinant Growth Hormone on the Congestive Heart Failure of Pig

    Institute of Scientific and Technical Information of China (English)

    Yang Ping; He Yu-quan; Zeng Hong; Ni Jin-song; Yun Qing-jun; Huang Xiao-ping; Li Shu-mei

    2005-01-01

    The enhanced cardiac contractility effect of human recombinant growth hormone (hr-GH) on the congestive heart failure (CHF) was studied on the pig. To build a pig model of congestive heart failure, a temporary artificial cardiac pacemaker was implanted in the pig's body and paced at 220 beats to 240 beats per minute for 1 week. After the model of congestive heart failure was successfully set up, the frequency of the pacemaker was changed to 150 beats to 180 beats per minute to maintain the CHF model stable. Pigs were divided into three groups: The hr-GH group in which 0.5 mg/kg per day of hr-GH was administrated intramuscularly for 15 days, the injection control group in which an equal amount of physiological saline was injected intramuscularly, and a normal control group. The left ventricular diastolic end pressure was (10.60±2.41 ) mmHg in the hr-GH group, but (19.00±3.81) mmHg in the saline control group (P<0.01); Cardiac output was (1.86±0.13) L/min in the hr-GH group, but (1.56 ±0.18) L/min in the saline control group (P<0.05); Peripheral min) -1 in the saline control group (P<0.05); ± dp/dtmax was (2900 ±316.23) and (2280 ±286.36) in the hr-HG group and the saline control group respectively (P<0.05). The results show that hr-GH enhances myocardial contractility of CHF, and the CHF model built by a temporary artificial cardiac pacemaker at a high rate of stimulation is reasonable and applicable.

  12. The dependence of radiofrequency induced pacemaker lead tip heating on the electrical conductivity of the medium at the lead tip.

    Science.gov (United States)

    Langman, Deborah A; Goldberg, Ira B; Judy, Jack; Paul Finn, J; Ennis, Daniel B

    2012-08-01

    Radiofrequency induced pacemaker lead tip heating is one of the main reasons magnetic resonance imaging (MRI) is contraindicated for patients with pacemakers. The objective of this work was to evaluate the dependence of pacemaker lead tip heating during MRI scanning on the electrical conductivity of the medium surrounding the pacemaker lead tip. The effect of conductivity was measured using hydroxyethyl cellulose, polyacrylic acid, and saline with conductivities ranging from 0 to 3 S/m which spans the range of human tissue conductivity. The maximum lead tip heating observed in polyacrylic acid was 50.4 °C at 0.28 S/m, in hydroxyethyl cellulose the maximum was 36.8 °C at 0.52 S/m, and in saline the maximum was 12.5 °C at 0.51 S/m. The maximum power transfer theorem was used to calculate the relative power deposited in the solution based on the characteristic impedance of the pacemaker lead and test solution impedance. The results demonstrate a strong correlation between the relative power deposited and pacemaker lead tip heating for hydroxyethyl cellulose and saline solutions. Maximum power deposition occurred when the impedance of the solution matched the pacemaker lead impedance. Pacemaker lead tip heating is dependent upon the electrical conductivity of the solution at the lead tip and should be considered when planning in vitro gel or saline experiments.

  13. The dynamics of GABA signaling: Revelations from the circadian pacemaker in the suprachiasmatic nucleus.

    Science.gov (United States)

    Albers, H Elliott; Walton, James C; Gamble, Karen L; McNeill, John K; Hummer, Daniel L

    2017-01-01

    Virtually every neuron within the suprachiasmatic nucleus (SCN) communicates via GABAergic signaling. The extracellular levels of GABA within the SCN are determined by a complex interaction of synthesis and transport, as well as synaptic and non-synaptic release. The response to GABA is mediated by GABAA receptors that respond to both phasic and tonic GABA release and that can produce excitatory as well as inhibitory cellular responses. GABA also influences circadian control through the exclusively inhibitory effects of GABAB receptors. Both GABA and neuropeptide signaling occur within the SCN, although the functional consequences of the interactions of these signals are not well understood. This review considers the role of GABA in the circadian pacemaker, in the mechanisms responsible for the generation of circadian rhythms, in the ability of non-photic stimuli to reset the phase of the pacemaker, and in the ability of the day-night cycle to entrain the pacemaker.

  14. [New pacemaker functions: which ones represent real progress and which are only gadgets?].

    Science.gov (United States)

    Dodinot, B

    2000-07-01

    Modern pacemakers, and particularly dual chamber models, include a broad array of therapeutic and diagnostic features. Some are designed to increase safety, whereas others are either designed to avoid unnecessary pacing, reduce the current drain and increase the pacemaker longevity, or to improve the hemodynamics. Diagnostic features are more elaborate, more or less automatic, and easier to extract from the pacemaker memory. Some of these new algorithms represent a real advantage, while others appear to be more like gadgets than real advances. Several new algorithms should be improved in order to avoid possibly dangerous side effects. Most of these new features are of little value in the absence of postoperative programming by a well trained physician.

  15. [The computer assisted pacemaker clinic at the regional hospital of Udine (author's transl)].

    Science.gov (United States)

    Feruglio, G A; Lestuzzi, L; Carminati, D

    1978-01-01

    For a close follow-up of large groups of pacemaker patients and for evaluation of long term pacing on a reliable statistical basis, many pacemaker centers in the world are now using computer systems. A patient data system with structured display records, designed to give complete, comprehensive and surveyable information and which are immediately retrievable 24 hours a day, on display or printed sets, seems to offer an ideal solution. The pacemaker clinic at the Regional Hospital of Udine has adopted this type of system. The clinic in linked to a live, on-line patient data system (G/3, Informatica Friuli-Venezia Giulia). The input and retrieval of information are made through a conventional keyboard. The input formats have fixed headings with coded alternatives and a limited space for comments in free text. The computer edits the coded information to surveyable reviews. Searches can be made on coded information and data of interest.

  16. Dynamic Breast Magnetic Resonance Imaging without Complications in a Patient with Dual-Chamber Demand Pacemaker

    Energy Technology Data Exchange (ETDEWEB)

    Sardanelli, F.; Lupo, P.; Esseridou, A.; Fausto, A.; Quarenghi, M. [Policlinico San Donato, San Donato Milanese, Milan (Italy). Depts. of Radiology, Arrhythmia and Electrophysiology Center

    2006-02-15

    Mammography and ultrasound indicated a cancer of the right breast in a 77-year-old woman with a dual-chamber demand pacemaker. The patient was not pacemaker-dependent. She underwent breast 1.5T magnetic resonance imaging (MRI) (dynamic gradient echo sequence with Gd-DOTA 0.1 mmol/kg). Before the patient entered the MR room, the configuration of the device was changed (the response to magnet was switched from asynchronous to off and the rate-responsive algorithm was disabled). No relevant modifications of heart rhythm or rate were observed during the MR examination. No symptom was reported. Immediately after the examination, the pacemaker interrogation showed neither program changes nor alert warnings. MRI detected a bifocal cancer in the right breast which allowed tailored breast-conserving treatment to be initiated. Histopathology confirmed a bifocal invasive ductal carcinoma.

  17. Autaptic pacemaker mediated propagation of weak rhythmic activity across small-world neuronal networks

    Science.gov (United States)

    Yilmaz, Ergin; Baysal, Veli; Ozer, Mahmut; Perc, Matjaž

    2016-02-01

    We study the effects of an autapse, which is mathematically described as a self-feedback loop, on the propagation of weak, localized pacemaker activity across a Newman-Watts small-world network consisting of stochastic Hodgkin-Huxley neurons. We consider that only the pacemaker neuron, which is stimulated by a subthreshold periodic signal, has an electrical autapse that is characterized by a coupling strength and a delay time. We focus on the impact of the coupling strength, the network structure, the properties of the weak periodic stimulus, and the properties of the autapse on the transmission of localized pacemaker activity. Obtained results indicate the existence of optimal channel noise intensity for the propagation of the localized rhythm. Under optimal conditions, the autapse can significantly improve the propagation of pacemaker activity, but only for a specific range of the autaptic coupling strength. Moreover, the autaptic delay time has to be equal to the intrinsic oscillation period of the Hodgkin-Huxley neuron or its integer multiples. We analyze the inter-spike interval histogram and show that the autapse enhances or suppresses the propagation of the localized rhythm by increasing or decreasing the phase locking between the spiking of the pacemaker neuron and the weak periodic signal. In particular, when the autaptic delay time is equal to the intrinsic period of oscillations an optimal phase locking takes place, resulting in a dominant time scale of the spiking activity. We also investigate the effects of the network structure and the coupling strength on the propagation of pacemaker activity. We find that there exist an optimal coupling strength and an optimal network structure that together warrant an optimal propagation of the localized rhythm.

  18. Pacemaker neuron and network oscillations depend on a neuromodulator-regulated linear current

    Directory of Open Access Journals (Sweden)

    Shunbing Zhao

    2010-05-01

    Full Text Available Linear leak currents have been implicated in the regulation of neuronal excitability, generation of neuronal and network oscillations, and network state transitions. Yet, few studies have directly tested the dependence of network oscillations on leak currents or explored the role of leak currents on network activity. In the oscillatory pyloric network of decapod crustaceans neuromodulatory inputs are necessary for pacemaker activity. A large subset of neuromodulators is known to activate a single voltage-gated inward current IMI, which has been shown to regulate the rhythmic activity of the network and its pacemaker neurons. Using the dynamic clamp technique, we show that the crucial component of IMI for the generation of oscillatory activity is only a close-to-linear portion of the current-voltage relationship. The nature of this conductance is such that the presence or the absence of neuromodulators effectively regulates the amount of leak current and the input resistance in the pacemaker neurons. When deprived of neuromodulatory inputs, pyloric oscillations are disrupted; yet, a linear reduction of the total conductance in a single neuron within the pacemaker group recovers not only the pacemaker activity in that neuron, but also leads to a recovery of oscillations in the entire pyloric network. The recovered activity produces proper frequency and phasing that is similar to that induced by neuromodulators. These results show that the passive properties of pacemaker neurons can significantly affect their capacity to generate and regulate the oscillatory activity of an entire network, and that this feature is exploited by neuromodulatory inputs.

  19. Effects of lubiprostone on pacemaker activity of interstitial cells of cajal from the mouse colon.

    Science.gov (United States)

    Jiao, Han-Yi; Kim, Dong Hyun; Ki, Jung Suk; Ryu, Kwon Ho; Choi, Seok; Jun, Jae Yeoul

    2014-08-01

    Lubiprostone is a chloride (Cl(-)) channel activator derived from prostaglandin E1 and used for managing constipation. In addition, lubiprostone affects the activity of gastrointestinal smooth muscles. Interstitial cells of Cajal (ICCs) are pacemaker cells that generate slow-wave activity in smooth muscles. We studied the effects of lubiprostone on the pacemaker potentials of colonic ICCs. We used the whole-cell patch-clamp technique to determine the pacemaker activity in cultured colonic ICCs obtained from mice. Lubiprostone hyperpolarized the membrane and inhibited the generation of pacemaker potentials. Prostanoid EP1, EP2, EP3, and EP4 antagonists (SC-19220, PF-04418948, 6-methoxypyridine-2-boronc acid N-phenyldiethanolamine ester, and GW627368, respectively) did not block the response to lubiprostone. L-NG-nitroarginine methyl ester (L-NAME, an inhibitor of nitric oxide synthase) and 1H-[1,2,4]oxadiazolo[4,3,-a]quinoxalin-1-one (ODQ, an inhibitor of guanylate cyclase) did not block the response to lubiprostone. In addition, tetraethylammonium (TEA, a voltage-dependent potassium [K(+)] channel blocker) and apamin (a calcium [Ca(2+)]-dependent K(+) channel blocker) did not block the response to lubiprostone. However, glibenclamide (an ATP-sensitive K(+) channel blocker) blocked the response to lubiprostone. Similar to lubiprostone, pinacidil (an opener of ATP-sensitive K(+) channel) hyperpolarized the membrane and inhibited the generation of pacemaker potentials, and these effects were inhibited by glibenclamide. These results suggest that lubiprostone can modulate the pacemaker potentials of colonic ICCs via activation of ATP-sensitive K(+) channel through a prostanoid EP receptor-independent mechanism.

  20. Solar battery energizer

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, M. E.

    1985-09-03

    A battery energizer for button batteries, such as zinc-silver oxide or zinc-mercuric oxide batteries, that are normally considered unchargeable, provides for energizing of the batteries in a safe and simple manner. A solar cell having a maximum current output (e.g., 20 milliamps) is operatively connected to terminals for releasably receiving a button battery. A light emitting diode, or like indicator, provides an indication of when the battery is fully energized, and additionally assists in preventing overenergization of the battery. The solar cell, terminals, LED, and the like can be mounted on a nonconductive material mounting plate which is mounted by a suction cup and hook to a window, adjacent a light bulb, or the like. A battery charger for conventional dry cell rechargeable batteries (such as nickel-cadmium batteries) utilizes the solar cells, and LED, and a zener diode connected in parallel with terminals. An adaptor may be provided with the terminal for adapting them for use with any conventional size dry cell battery, and a simple dummy battery may be utilized so that less than the full complement of batteries may be charged utilizing the charger.

  1. Redoing a bioprosthetic tricuspid valve replacement with pacemaker wire through the ruined bioprosthetic valve orifice

    Institute of Scientific and Technical Information of China (English)

    GUO Hong-wei; PAN Shi-wei; SONG Yun-hu; HU Sheng-shou

    2011-01-01

    Severe tricuspid regurgitation with permanent pacemaker wire passing through the orifice of bioprosthetic tricuspid valve is extremely rare. We present a case of such kind of patient and redid bioprosthetic tricuspid valve replacement. A hawk mouth forceps for bone surgery was used to cut off the mental ring of ruined bioprosthetic tricuspid valve and the ruined valve was removed. A new bioprosthetic tricuspid valve was implanted and the wire of permanent pacemaker was left outside the ring of bioprosthetic tricuspid valve. This method may be helpful for such kind of patient.

  2. Calcium Transient and Sodium-Calcium Exchange Current in Human versus Rabbit Sinoatrial Node Pacemaker Cells

    OpenAIRE

    Verkerk, Arie O.; Marcel M. G. J. van Borren; Ronald Wilders

    2013-01-01

    There is an ongoing debate on the mechanism underlying the pacemaker activity of sinoatrial node (SAN) cells, focusing on the relative importance of the “membrane clock” and the “Ca2+ clock” in the generation of the small net membrane current that depolarizes the cell towards the action potential threshold. Specifically, the debate centers around the question whether the membrane clock-driven hyperpolarization-activated current, I f , which is also known as the “funny current” or “pacemaker c...

  3. Electromagnetic interference with a bipolar pacemaker by an induction heating (IH) rice cooker.

    Science.gov (United States)

    Nagatomo, Toshihisa; Abe, Haruhiko; Kohno, Ritsuko; Toyoshima, Takeshi; Fujimoto, Hiroshi; Kondo, Shoichi; Kabashima, Narutoshi; Takeuchi, Masaaki; Tamura, Masahito; Okazaki, Masahiro; Otsuji, Yutaka

    2009-01-01

    Electromagnetic fields may interfere with normal pacemaker function. Despite new device designs and bipolar leads, electromagnetic interference (EMI) remains a concern when pacemaker recipients are exposed to various household appliances. We report the observation of EMI by an induction heating (IH) rice cooker in a patient with sick sinus syndrome who was the recipient of a bipolar dual chamber-pacing system. Stored electrograms revealed episodes of inappropriate ventricular pacing, all coinciding with the opening of an IH rice cooker. Recipients of implantable medical devices must be warned to handle IH rice cookers with caution.

  4. Multiple photoreceptor systems control the swim pacemaker activity in box jellyfish

    DEFF Research Database (Denmark)

    Garm, Anders Lydik; Mori, S.

    2009-01-01

    Like all other cnidarian medusae, box jellyfish propel themselves through the water by contracting their bell-shaped body in discrete swim pulses. These pulses are controlled by a swim pacemaker system situated in their sensory structures, the rhopalia. Each medusa has four rhopalia each with a s......Like all other cnidarian medusae, box jellyfish propel themselves through the water by contracting their bell-shaped body in discrete swim pulses. These pulses are controlled by a swim pacemaker system situated in their sensory structures, the rhopalia. Each medusa has four rhopalia each...

  5. Pacemaker repetitive nonreentrant ventriculoatrial synchrony. Why did automatic mode switching occur?

    Science.gov (United States)

    Barold, S Serge; Stroobandt, Roland X; Van Heuverswyn, Frederic

    2012-01-01

    Repetitive nonreentrant ventriculoatrial synchrony during dual-chamber pacing is characterized by long intervals alternating with short intervals. This arrangement activated automatic mode switching in a St Jude dual-chamber pacemaker in which the algorithm requires an atrial sensed event for automatic mode switching initiation. Automatic mode switching activation by an atrial sensed event (retrograde P wave) was puzzling because the programmed postventricular atrial period was longer than the retrograde ventriculoatrial conduction time. The explanation is presented in the form of questions and answers to facilitate the understanding of pacemaker function and complex timing cycles.

  6. Liénard-type models for the simulation of the action potential of cardiac nodal cells

    Science.gov (United States)

    Podziemski, P.; Żebrowski, J. J.

    2013-10-01

    Existing models of cardiac cells which include multi-variable cardiac transmembrane current are too complex to simulate the long time dynamical properties of the heart rhythm. The large number of parameters that need to be defined and set for such models make them not only cumbersome to use but also require a large computing power. Consequently, the application of such models for the bedside analysis of heart rate of a specific patient may be difficult. Other ways of modelling need to be investigated. We consider the general problem of developing a model of cardiac pacemaker tissue that allows to combine the investigation of phenomena at a time scale of thousands of heart beats with the ability to reproduce realistic tissue-level characteristics of cell dynamics. We propose a modified van der Pol-Duffing equation-a Liénard-type oscillator-as a phenomenological model for cardiac nodal tissue, with certain important physiological similarities to ion-channel models of cardiac pacemaker cells. The model presented here is specifically designed to qualitatively reproduce mesoscopic characteristics of cell dynamics, including action potential duration (APD) restitution properties, phase response characteristics, and phase space structure. We show that these characteristics agree qualitatively with the extensive ionic models and experimental results in the literature [Anumonwo et al., 1991, [33], Cao et al., 1999, [49], Coster and Celler, 2003, [31], Qu, 2004, [45], Tsalikakis et al., 2007, [32], Inada et al., 2009, [14], Qu et al., 2010, [50

  7. Ionene membrane battery separator

    Science.gov (United States)

    Moacanin, J.; Tom, H. Y.

    1969-01-01

    Ionic transport characteristics of ionenes, insoluble membranes from soluble polyelectrolyte compositions, are studied for possible application in a battery separator. Effectiveness of the thin film of separator membrane essentially determines battery lifetime.

  8. 基层医院临时心脏起搏器的安装%Temporary pacemaker installed in primary hospital

    Institute of Scientific and Technical Information of China (English)

    陈志红; 张红英

    2013-01-01

    Objective To utilize Seldinger technique via the right subclavian vein puncture install temporary pacemaker in primary hospital. Methods Applied Medtronic5318 temporary pacemaker,utilized Seldinger technique,entered the superior vena cava from the inside and lower 1/3 of the right clavicle under the X-ray intermittent exposure time monitoring, after that, placed J-shaped guide wire,the pacing catheter through the right atrioventricular valve into the right ventricular apex,and Installed temporary pacemaker when contacted with endocardial. Results 15 patients were all successfully placed temporary pacing catheter,temporary pacemaker pacing, postoperative ECG. 1 case of poor pacing, the other 14 cases of satisfactory pacing.There were no complications. Conclusion Under the X-ray intermittent exposure time monitoring,right subclavian vein puncture and catheterization installing temporary cardiac pacing, patients and operators accept less X-ray dose, this method is intuitive, accurate, safe, minimally invasive, high success rate,it's fit for primary hospital to install temporary pacemaker, worthy for primary hospital clinical practice.%目的:基层医院采用Seldinger技术经右锁骨下静脉穿刺安装临时起搏器。方法应用Medtronic5318临时心脏起搏器,采用Seldinger技术法,在X线间断曝光实时监视下,经右锁骨内侧中下1/3处进入上腔静脉,然后置入J形导丝,将起搏导管通过右房室瓣送入右心室心尖部并接触心内膜安装临时心脏起搏器。结果15例患者均顺利置入临时起搏导管,接临时起搏器起搏,术后心电监护。其中1例起搏效果差,其余14例起搏效果满意。本组无并发症发生。结论 X线间断曝光实时监视下右锁骨下静脉穿刺及导管植入安装临时心脏起搏,患者及操作者接受X线剂量少,此法直观、准确、安全,微创,成功率高,适合基层医院临时心脏起搏器的安装,值得基层医院临床推广。

  9. Rechargeable batteries applications handbook

    CERN Document Server

    1998-01-01

    Represents the first widely available compendium of the information needed by those design professionals responsible for using rechargeable batteries. This handbook introduces the most common forms of rechargeable batteries, including their history, the basic chemistry that governs their operation, and common design approaches. The introduction also exposes reader to common battery design terms and concepts.Two sections of the handbook provide performance information on two principal types of rechargeable batteries commonly found in consumer and industrial products: sealed nickel-cad

  10. Battery systems engineering

    CERN Document Server

    Rahn, Christopher D

    2012-01-01

    A complete all-in-one reference on the important interdisciplinary topic of Battery Systems Engineering Focusing on the interdisciplinary area of battery systems engineering, this book provides the background, models, solution techniques, and systems theory that are necessary for the development of advanced battery management systems. It covers the topic from the perspective of basic electrochemistry as well as systems engineering topics and provides a basis for battery modeling for system engineering of electric and hybrid electric vehicle platforms. This original

  11. Cardiac MRI in Athletes

    NARCIS (Netherlands)

    Luijkx, T.

    2012-01-01

    Cardiac magnetic resonance imaging (CMR) is often used in athletes to image cardiac anatomy and function and is increasingly requested in the context of screening for pathology that can cause sudden cardiac death (SCD). In this thesis, patterns of cardiac adaptation to sports are investigated with C

  12. Electric Vehicle Battery Challenge

    Science.gov (United States)

    Roman, Harry T.

    2014-01-01

    A serious drawback to electric vehicles [batteries only] is the idle time needed to recharge their batteries. In this challenge, students can develop ideas and concepts for battery change-out at automotive service stations. Such a capability would extend the range of electric vehicles.

  13. Battery charging system

    Energy Technology Data Exchange (ETDEWEB)

    Carollo, J.A.; Kalinsky, W.A.

    1984-02-21

    A battery charger utilizes three basic modes of operation that includes a maintenance mode, a rapid charge mode and time controlled limited charging mode. The device utilizes feedback from the battery being charged of voltage, current and temperature to determine the mode of operation and the time period during which the battery is being charged.

  14. Effect of Alcohol on Pacemaking and Driving Function of Sinoatrail Node in Heart of Mammals%乙醇对哺乳动物心脏窦房结搏动信号传导功能的影响

    Institute of Scientific and Technical Information of China (English)

    程睿; 张季谦; 李翔; 高飞

    2013-01-01

    利用哺乳动物心脏窦房结组织的二维解剖模型,模拟乙醇对窦房结搏动及信号传导功能的影响.结果发现,一方面摄入过量的乙醇会使得有生理缺陷的心脏体系出现异常搏动现象,这与临床实验现象相吻合.另一方面发现,摄入乙醇对于窦房结搏动功能有三类影响:降低L型钙离子通道的导电性能;减小神经系统分泌乙酰胆碱的能力;若过量摄入乙醇,则降低钠离子通道的导电性能.这三种情况都将直接影响窦房结组织的正常搏动功能.模拟结果有助于进一步理解因摄入乙醇而引发心脏体系异常搏动的内在机理,并为临床诊断和预防提供一定的理论参考.%By using a 2D anatomical model of the intake SA node and surrounding atrial muscle of the rabbit heart,which is proposed by Zhang et al,the effect of the alcohol on pacemaking and driving function of sinoatrail node is investigated by computer simulation.The results show,on one hand,excessive intake of the alcohol can reproduce the phenomenon of abnormal rhythm in heart with physiological defect,which are consistent with the clinical phenomena,such as abnormal pacemaking or even sudden cardiac death,which is induced by reduction of the ethanol irrigation stomach experiment on rabbit.On the other hand,using this model can simulate the influence of SA node which has the ethanol intake,and the influences perform in three aspects:reduce the electric conductivity of L calcium ion channels; reduce the ability to secrete acetylcholine of the nervous system; in excess intake of ethanol,reduce the electric conductivity of sodium channel.These three factors directly affect the pacemaking and driving function of sinoatrail node.These results will help to reveal the internal mechanism of the abnormal pacemaking in complex cardiac system absorbing the ethanol and provide a theoretical guidance for the clinical diagnosis of angiocardiopathy.

  15. Cardiac Damage from Chronic Use of Chloroquine: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Ricardo Alkmim Teixeira

    2002-07-01

    Full Text Available Chloroquine has been widely used in rheumatological treatment, but potential severe side effects require careful follow-up. Cardiac damage is not a common consequence, but its clinical relevance has not yet been described. We report the case of a 58-year-old woman with rheumatoid arthritis, in whom chronic chloroquine use resulted in major irreversible cardiac damage. She presented with syncopal episodes due to complete atrioventricular block confirmed by electrophysiological study whose changes were concluded to be irreversible and a permanent pacemaker was indicated. Endomyocardial biopsy was also performed to search for histopathological and ultrastructural cardiac damage. We also reviewed the 22 cases of chloroquine-induced cardiopathy described to date as well as its pathophysiology.

  16. Cardiac amyloidosis detection with pyrophosphate-99mTc scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Souza, D.S.F.; Ichiki, W.A.; Coura Filho, G.B.; Izaki, M.; Giorgi, M.C.P.; Soares Junior, J; Meneghetti, J.C. [Universidade de Sao Paulo (FM/USP), SP (Brazil). Fac. de Medicina. Instituto do Coracao. Servico de Medicina Nuclear e Imagem Molecular

    2008-07-01

    Full text: Introduction: Amyloidosis is a rare disease, characterized by extracellular deposition of insoluble amyloid fibrils in organs and tissues. It may affect virtually any system, preferably heart, kidneys and liver. The cardiac involvement produces a spectrum of clinical features, usually with progressive dysfunction. Early diagnosis is important for institution of appropriate therapy. Case report: Male patient, 75 years old, with diagnosed congestive heart failure functional class III and Mobitz II second-degree atrial-ventricular block, was hospitalized for implantation of definitive cardiac pacemaker. Patient mentioned history of worsening effort dyspnoea over a one-month period, progressing to minimum effort, orthopnea, paroxysmal nocturnal dyspnoea and paroxysms of dry cough, and swelling of lower limbs. Echocardiography showed diffuse hypertrophy of left ventricle (LV), with systolic dysfunction due to diffuse hypokinesia and hyperrefringent aspect in the septum. It was questioned a cardiac infiltrating process. Cardiac amyloidosis was considered as a diagnostic hypothesis. The patient underwent a pyrophosphate-{sup 99m}Tc scintigraphy, which showed abnormal tracer uptake in the heart projection, with diffuse pattern on the left ventricle walls, compatible with the clinical suspicion cardiac amyloidosis, which was later confirmed by endomyocardial biopsy. Discussion: In this case report, the patient had clinical and other auxiliary examinations, such as electrocardiography and Doppler echocardiography, compatible with cardiac amyloidosis, which led to implementation with pyrophosphate-{sup 99m}Tc scintigraphy and later endomyocardial biopsy. Cardiac amyloidosis occurs in about half the cases of primary amyloidosis (AL) and is rare in secondary amyloidosis (AA). Its clinical presentation is polymorphic and it can be classified into four distinctive types: restrictive cardiomyopathy, systolic dysfunction, postural hypotension and conduction disorders

  17. New evidence for coupled clock regulation of the normal automaticity of sinoatrial nodal pacemaker cells: bradycardic effects of ivabradine are linked to suppression of intracellular Ca2+ cycling

    Science.gov (United States)

    Yaniv, Yael; Sirenko, Syevda; Ziman, Bruce D.; Spurgeon, Harold A.; Maltsev, Victor A.; Lakatta, Edward G.

    2013-01-01

    Beneficial clinical bradycardic effects of ivabradine (IVA) have been interpreted solely on the basis of If inhibition, because IVA specifically inhibits If in sinoatrial nodal pacemaker cells (SANC). However, it has been recently hypothesized that SANC normal automaticity is regulated by crosstalk between an “M clock,” the ensemble of surface membrane ion channels, and a “Ca2+ clock,” the sarcoplasmic reticulum (SR). We tested the hypothesis that crosstalk between the two clocks regulates SANC automaticity, and that indirect suppression of the Ca2+ clock further contributes to IVA-induced bradycardia. IVA (3μM) not only reduced If amplitude by 45±6% in isolated rabbit SANC, but the IVA-induced slowing of the action potential (AP) firing rate was accompanied by reduced SR Ca2+ load, slowed intracellular Ca2+ cycling kinetics, and prolonged the period of spontaneous local Ca2+ releases (LCRs) occurring during diastolic depolarization. Direct and specific inhibition of SERCA2 by cyclopiazonic acid (CPA) had effects similar to IVA on LCR period and AP cycle length. Specifically, the LCR period and AP cycle length shift toward longer times almost equally by either direct perturbations of the M clock (IVA) or the Ca2+ clock (CPA), indicating that the LCR period reports the crosstalk between the clocks. Our numerical model simulations predict that entrainment between the two clocks that involves a reduction in INCX during diastolic depolarization is required to explain the experimentally AP firing rate reduction by IVA. In summary, our study provides new evidence that a coupled-clock system regulates normal cardiac pacemaker cell automaticity. Thus, IVA-induced bradycardia includes a suppression of both clocks within this system. PMID:23651631

  18. Nanowires and Electrical Stimulation Synergistically Improve Functions of hiPSC Cardiac Spheroids.

    Science.gov (United States)

    Richards, Dylan J; Tan, Yu; Coyle, Robert; Li, Yang; Xu, Ruoyu; Yeung, Nelson; Parker, Arran; Menick, Donald R; Tian, Bozhi; Mei, Ying

    2016-07-13

    The advancement of human induced pluripotent stem-cell-derived cardiomyocyte (hiPSC-CM) technology has shown promising potential to provide a patient-specific, regenerative cell therapy strategy to treat cardiovascular disease. Despite the progress, the unspecific, underdeveloped phenotype of hiPSC-CMs has shown arrhythmogenic risk and limited functional improvements after transplantation. To address this, tissue engineering strategies have utilized both exogenous and endogenous stimuli to accelerate the development of hiPSC-CMs. Exogenous electrical stimulation provides a biomimetic pacemaker-like stimuli that has been shown to advance the electrical properties of tissue engineered cardiac constructs. Recently, we demonstrated that the incorporation of electrically conductive silicon nanowires to hiPSC cardiac spheroids led to advanced structural and functional development of hiPSC-CMs by improving the endogenous electrical microenvironment. Here, we reasoned that the enhanced endogenous electrical microenvironment of nanowired hiPSC cardiac spheroids would synergize with exogenous electrical stimulation to further advance the functional development of nanowired hiPSC cardiac spheroids. For the first time, we report that the combination of nanowires and electrical stimulation enhanced cell-cell junction formation, improved development of contractile machinery, and led to a significant decrease in the spontaneous beat rate of hiPSC cardiac spheroids. The advancements made here address critical challenges for the use of hiPSC-CMs in cardiac developmental and translational research and provide an advanced cell delivery vehicle for the next generation of cardiac repair.

  19. Transcription factor ISL1 is essential for pacemaker development and function.

    Science.gov (United States)

    Liang, Xingqun; Zhang, Qingquan; Cattaneo, Paola; Zhuang, Shaowei; Gong, Xiaohui; Spann, Nathanael J; Jiang, Cizhong; Cao, Xinkai; Zhao, Xiaodong; Zhang, Xiaoli; Bu, Lei; Wang, Gang; Chen, H S Vincent; Zhuang, Tao; Yan, Jie; Geng, Peng; Luo, Lina; Banerjee, Indroneal; Chen, Yihan; Glass, Christopher K; Zambon, Alexander C; Chen, Ju; Sun, Yunfu; Evans, Sylvia M

    2015-08-01

    The sinoatrial node (SAN) maintains a rhythmic heartbeat; therefore, a better understanding of factors that drive SAN development and function is crucial to generation of potential therapies, such as biological pacemakers, for sinus arrhythmias. Here, we determined that the LIM homeodomain transcription factor ISL1 plays a key role in survival, proliferation, and function of pacemaker cells throughout development. Analysis of several Isl1 mutant mouse lines, including animals harboring an SAN-specific Isl1 deletion, revealed that ISL1 within SAN is a requirement for early embryonic viability. RNA-sequencing (RNA-seq) analyses of FACS-purified cells from ISL1-deficient SANs revealed that a number of genes critical for SAN function, including those encoding transcription factors and ion channels, were downstream of ISL1. Chromatin immunoprecipitation assays performed with anti-ISL1 antibodies and chromatin extracts from FACS-purified SAN cells demonstrated that ISL1 directly binds genomic regions within several genes required for normal pacemaker function, including subunits of the L-type calcium channel, Ank2, and Tbx3. Other genes implicated in abnormal heart rhythm in humans were also direct ISL1 targets. Together, our results demonstrate that ISL1 regulates approximately one-third of SAN-specific genes, indicate that a combination of ISL1 and other SAN transcription factors could be utilized to generate pacemaker cells, and suggest ISL1 mutations may underlie sick sinus syndrome.

  20. Local induction of pacemaking activity in a monolayer of electrically coupled quiescent NRK fibroblasts

    NARCIS (Netherlands)

    Dernison, M.M.; Kusters, J.M.A.M.; Peters, P.H.J.; Meerwijk, W.P. van; Ypey, D.L.; Gielen, C.C.A.M.; Zoelen, E.J.J. van; Theuvenet, A.P.R.

    2008-01-01

    Cultures of normal rat kidney (NRK) fibroblasts may display spontaneous calcium action potentials which propagate throughout the cellular monolayer. Pacemaking activity of NRK cells was studied by patch clamp electrophysiology and vital calcium imaging, using a new experimental approach in which a r

  1. Potential additional indicators for pacemaker requirement in isolated congenital atrioventricular block.

    NARCIS (Netherlands)

    Breur, J.M.; Udink ten Cate, F.E.; Kapusta, L.; Boramanand, N.; Cohen, M.I.; Crosson, J.E.; Lubbers, L.J.; Friedman, A.H.; Brenner, J.I.; Vetter, V.L.; Meijboom, E.J.

    2006-01-01

    Low heart rate is the predominantly used indication for pacemaker intervention in patients with isolated congenital atrioventricular block (CAVB). The aim of this study was to compare the difference in heart rates recorded with ECG and Holter monitoring between paced (PM) and nonpaced (NPM) patients

  2. Potential additional indicators for pacemaker requirement in isolated congenital atrioventricular block

    NARCIS (Netherlands)

    J.M.P.J. Breur; F.E.A.U. ten Cate; L. Kapusta; N. Boramanand; M.I. Cohen; J.E. Crosson; L.J. Lubbers; A.H. Friedman; J.I. Brenner; V.L. Vetter; E.J. Meijboom

    2006-01-01

    Low heart rate is the predominantly used indication for pacemaker intervention in patients with isolated congenital atrioventricular block (CAVB). The aim of this study was to compare the difference in heart rates recorded with ECG and Holter monitoring between paced (PM) and nonpaced (NPM) patients

  3. Inadvertent implantation of pacemaker lead in the left ventricle: kill two birds with one stone.

    Science.gov (United States)

    Turk, Ugur Onsel; Tuncer, Esref; Alioglu, Emin; Tengiz, Istemihan; Ercan, Ertugrul

    2014-04-01

    We report an asymptomatic patient in whom the intravenous pacemaker (PM) lead was inadvertently implanted in LV through the perforated interventricular septum. He had no embolic events during the last 9 years after the implantation. Possible explanation of the uncomplicated follow-up period is that the patient had been taking warfarin because of mechanical mitral valve prosthesis.

  4. Survival of 4 dogs with persistent atrial standstill treated by pacemaker implantation.

    Science.gov (United States)

    Thomason, Justin D; Kraus, Marc S; Fallaw, Tiffany L; Calvert, Clay A

    2016-03-01

    Pacemakers were implanted in 4 client-owned female dogs which had persistent atrial standstill. Three dogs were alive after 14 to 39 months and 1 dog was euthanized after 10.5 years. This report demonstrates that some dogs with persistent atrial standstill can survive for extended time periods.

  5. Safety of magnetic resonance scanning without monitoring of patients with pacemakers

    DEFF Research Database (Denmark)

    Bertelsen, Litten; Petersen, Helen Høgh; Philbert, Berit Thornvig;

    2017-01-01

    AIMS: The objective of this study was to investigate whether it is safe to perform 1.5-Tesla magnetic resonance imaging (MRI) scans in pacemaker (PM) patients without pulse oximetry or electrocardiogram monitoring and with no special specific absorption rate (SAR) or time limits, provided...

  6. Influence of Continuous Nursing on the Psychological State and Coping Style of Patients Undergoing Pacemaker Implantation

    Directory of Open Access Journals (Sweden)

    Xin LIU

    2015-10-01

    Full Text Available Background: Patients undergoing pacemaker implantation often experience anxiety and fear. As such, studies have focused on the mechanisms that relieve the negative emotions caused by the intervention. Continuous nursing is a safe and effective nursing mode. In this study, continuous nursing intervention was provided for elderly patients undergo-ing pacemaker implantation and an empirical investigation was performed to determine the effects of their negative emotion and disease-coping ability.Methods: Overall, 114 (68 males and 46 females elderly patients who were undergoing pacemaker implantation from Harbin City (China, were enrolled in the study. The patients were divided into two groups, namely, the control group and the intervention group, based on different nursing methods. Routine nursing was applied to the control group; continuous nursing support was provided for the intervention group from January 2014 to January 2015. The nursing results of the two groups were compared. These results were also evaluated using self-rating depression scale, self-rating anxiety scale, and trait coping style questionnaire.Result: The effects of depression and anxiety intervention were significant in the intervention group (P<0.05. Com-pared with the control group, the intervention group did not significantly differ. The coping style of the intervention group elicited significant effects. Compared with the control group, the intervention group was significantly different (P < 0.05.Conclusion: Continuous nursing can relieve the negative emotion and improve the negative coping style of patients undergoing pacemaker implantation.

  7. Reevaluation of the indications for permanent pacemaker implantation after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Bjerre Thygesen, Julie; Loh, Poay Huan; Cholteesupachai, Jiranut

    2014-01-01

    AIMS: Conduction abnormalities (CA) requiring permanent pacemaker (PPM) are a well-known complication after transcatheter aortic valve implantation (TAVI). This study aimed to determine the incidence of TAVI-related PPM and reevaluate the indications for PPM after the periprocedural period. METHO...

  8. Interruption of pacemaker signals by a diencephalic nucleus in the African electric fish, Gymnarchus niloticus.

    Science.gov (United States)

    Zhang, Ying; Kawasaki, Masashi

    2006-05-01

    The African electric fish Gymnarchus niloticus rhythmically emits electric organ discharges (EODs) for communication and navigation. The EODs are generated by the electric organ in the tail in response to the command signals from the medullary pacemaker complex, which consists of a pacemaker nucleus (PN), two lateral relay nuclei (LRN) and a medial relay nucleus (MRN). The premotor structure and its modulatory influences on the pacemaker complex have been investigated in this paper. A bilateral prepacemaker nucleus (PPn) was found in the area of the dorsal posterior nucleus (DP) of the thalamus by retrograde labeling from the PN. No retrogradely labeled neurons outside the pacemaker complex were found after tracer injection into the LRN or MRN. Accordingly, anterogradely labeled terminal fibers from PPn neurons were found only in the PN. Iontophoresis of L-glutamate into the region of the PPn induced EOD interruptions. Despite the exclusive projection of the PPn neurons to the PN, extracellular and intracellular recordings showed that PN neurons continue their firing while MRN neurons ceased their firing during EOD interruption. This mode of EOD interruption differs from those found in any other weakly electric fishes in which EOD cessation mechanisms have been known.

  9. Interventional guidance for cardiac resynchronization therapies: merging anatomic X-ray imaging with functional ultrasound imaging based on mutually-shared landmarks

    Energy Technology Data Exchange (ETDEWEB)

    Manzke, R.; Shechter, G.; Gutierrez, L.; Chan, R.C. [Philips Research North America, Briarcliff Manor, NY (United States); Tournoux, F.; Singh, J.; Picard, M. [Dept. of Cardiology, Massachusetts General Hospital, Harvard Medical School (United States); Brink, B. v.d.; Boomen, R. v.d. [Philips Medical System, Best (Netherlands); Gerard, O. [Philips Medical Systems, Paris (France)

    2007-06-15

    Detailed knowledge of cardiac anatomy and function is required for complex cardiac electrophysiology interventions. Cardiac resynchronization therapies (CRT), for example, requires information about coronary venous anatomy for left ventricular lead placement. In CRT, heart failure patients are equipped with dual-chamber pacemakers in order to improve cardiac output and heart failure symptoms. Cardiac function is mainly assessed with Ultrasound imaging. Fusion of complementary information from X-ray and ultrasound is an essential step towards fully utilizing all available information for CRT guidance. We present an approach for fusion of anatomical information (coronary vein structure) from X-ray with functional information (left ventricular deformation and dynamics) from ultrasound. We propose an image-based fusion approach based on mutually-shared landmarks which enable registration of both imaging spaces without the need for external tracking. (orig.)

  10. Correlation analysis of the relationship between B-type natriuretic peptide and selected echocardiographic parameters in patients with permanent pacemakers

    Directory of Open Access Journals (Sweden)

    Janusz Sielski

    2016-01-01

    Full Text Available Introduction: The present study was undertaken to evaluate the practical value of BNP measurements and echocardiographic left ventricular volume index in patients with permanent pacemakers because there are no such reports in the literature. Aim of the research: The aim of the study was to reveal multiple correlations between BNP levels and selected echocardiographic parameters of the left atrium in patients with permanent pacemakers. In the literature there are reports on the significance of BNP values and left atrial size in patients with permanent pacemakers. The results of the present study appear to be of value in the outpatient assessment of these patients. Material and methods: We analysed a group of 117 patients with permanent pacemakers (AAI/R 21 patients, DDD/R 59 patients, VVI/R 37 patients and 48 healthy volunteers serving as the control group. BNP measurements were performed on venous blood samples using Triage meters. The Simpson method and the ellipse method were used to assess the left atrium on echocardiography. Results: There was a significant correlation between BNP and maximum left atrial volume, minimum left atrial volume, and left atrial volume index in patients with AAI/R, DDD/R, and VVI/R pacemakers at 3 and 6 months after the implantation. Conclusions : In patients after implantation of permanent pacemakers there are correlations between BNP values and echocardiographic left atrial parameters, especially in patients with DDD/R pacemakers. Left atrial function improves in patients with DDD/R pacemakers. Pacemaker check-up should be extended to include BNP measurements and echocardiographic assessment of the left atrium.

  11. EVALUATION CARDIAC RESYNCHRONIZATION THERAPY IN PATIENTS WITH CHRONIC ISCHEMIC HEART FAILURE

    Directory of Open Access Journals (Sweden)

    A. J. Fishman

    2011-01-01

    Full Text Available Objective — studying dyssynchrony characteristics and evaluation correction effectiveness in patients with chronic heart failure (CHF of ischemic origin.Materials and methods. The study included 125 patients with chronic heart failure of ischemic etiology, 28 of them — with coronary heart disease (CHD who had undergone aorto-and / or mammarokoronary bypass and / or percutaneous coronary intervention, 42 — with coronary artery disease and postinfarction cardiosclerosis, 32 — with arrhythmic variant of coronary artery disease, 23 — with stable angina without evidence of arrhythmia. Among included patients, biventricular pacemakers were implanted for 17 patients. All patients underwent echocardiography with determination of the parameters of dyssynchrony.Results and conclusion. Among patients with CHF ischemic symptoms dyssynchrony was diagnosed in 36 (28.8 % cases. Statistically significant association between patients with cardiac arrhythmias and dyssynchrony was determined. At the same time the incidence of dyssynchrony was not associated with various forms of ischemic heart disease, and did not depend on the anamnesis of cardiac surgery. Dependence of the frequency of occurrence of dyssynchrony on the severity of CHF was revealed. Patients selected for implantation of biventricular pacemakers, especially in view of echocardiographic signs of dyssynchrony had significant improvement after providing cardiac resynchronization therapy. Effect of the treatment does not depend on the atrial fibrillation rhythm presence.

  12. EVALUATION CARDIAC RESYNCHRONIZATION THERAPY IN PATIENTS WITH CHRONIC ISCHEMIC HEART FAILURE

    Directory of Open Access Journals (Sweden)

    A. J. Fishman

    2014-07-01

    Full Text Available Objective — studying dyssynchrony characteristics and evaluation correction effectiveness in patients with chronic heart failure (CHF of ischemic origin.Materials and methods. The study included 125 patients with chronic heart failure of ischemic etiology, 28 of them — with coronary heart disease (CHD who had undergone aorto-and / or mammarokoronary bypass and / or percutaneous coronary intervention, 42 — with coronary artery disease and postinfarction cardiosclerosis, 32 — with arrhythmic variant of coronary artery disease, 23 — with stable angina without evidence of arrhythmia. Among included patients, biventricular pacemakers were implanted for 17 patients. All patients underwent echocardiography with determination of the parameters of dyssynchrony.Results and conclusion. Among patients with CHF ischemic symptoms dyssynchrony was diagnosed in 36 (28.8 % cases. Statistically significant association between patients with cardiac arrhythmias and dyssynchrony was determined. At the same time the incidence of dyssynchrony was not associated with various forms of ischemic heart disease, and did not depend on the anamnesis of cardiac surgery. Dependence of the frequency of occurrence of dyssynchrony on the severity of CHF was revealed. Patients selected for implantation of biventricular pacemakers, especially in view of echocardiographic signs of dyssynchrony had significant improvement after providing cardiac resynchronization therapy. Effect of the treatment does not depend on the atrial fibrillation rhythm presence.

  13. Electrochemical accumulators batteries; Accumulateurs electrochimiques batteries

    Energy Technology Data Exchange (ETDEWEB)

    Ansart, F.; Castillo, S.; Laberty- Robert, C.; Pellizon-Birelli, M. [Universite Paul Sabatier, Lab. de Chimie des Materiaux Inorganiques et Energetiques, CIRIMAT, UMR CNRS 5085, 31 - Toulouse (France)] [and others

    2000-07-01

    It is necessary to storage the electric power in batteries to join the production and the utilization. In this domain progresses are done every days in the technics and also in the available materials. These technical days present the state of the art in this domain. Many papers were presented during these two days giving the research programs and recent results on the following subjects: the lithium batteries, the electrolytes performances and behaviour, lead accumulators, economic analysis of the electrochemical storage market, the batteries applied to the transportation sector and the telephones. (A.L.B.)

  14. A case of delayed cardiac perforation of active ventricular lead

    Directory of Open Access Journals (Sweden)

    Hangyuan Guo

    2011-12-01

    Full Text Available A 65-year-old man was admitted as for one month of repetitive dizziness and one episode of syncope. Electrocardiogram showed sinus bradycardia and his Holter monitoring also showed sinus bradycardia with sinus arrest, sino-atrial block and a longest pause of 4.3 s. Then sick sinus syndrome and Adam-Stokes syndrome were diagnosed. Then a dual chamber pacemaker (Medtronic SDR303 was implanted and the parameters were normal by detection. The patient was discharged 1 week later with suture removed. Then 1.5 month late the patient was presented to hospital once again for sudden onset of chest pain with exacerbation after taking deep breath. Pacemaker programming showed both pacing and sensing abnormality with threshold of?5.0V and resistance of 1200?. Lead perforation was revealed by chest X-ray and confirmed by echocardiogram. Considering the fact that there was high risk to remove ventricular lead, spiral tip of previous ventricular lead was withdrew followed by implantation of a new ventricular active lead to the septum. Previous ventricular lead was maintained. As we know that the complications of lead perforation in the clinic was rare. Here we discuss the clinical management and the possible reasons for cardiac perforation of active ventricular lead.

  15. Infective endocarditis and risk of death after cardiac implantable electronic device implantation

    DEFF Research Database (Denmark)

    Özcan, Cengiz; Raunsø, Jakob; Lamberts, Morten;

    2017-01-01

    AIMS: To determine the incidence, risk factors, and mortality of infective endocarditis (IE) following implantation of a first-time, permanent, cardiac implantable electronic device (CIED). METHODS AND RESULTS: From Danish nationwide administrative registers (beginning in 1996), we identified all...... de-novo permanent pacemakers (PMs) and implantable cardioverter defibrillators (ICDs) together with the occurrence of post-implantation IE-events in the period from 2000-2012. Included were 43 048 first-time PM/ICD recipients. Total follow-up time was 168 343 person-years (PYs). The incidence rate...

  16. Electric-vehicle batteries

    Science.gov (United States)

    Oman, Henry; Gross, Sid

    1995-02-01

    Electric vehicles that can't reach trolley wires need batteries. In the early 1900's electric cars disappeared when owners found that replacing the car's worn-out lead-acid battery costs more than a new gasoline-powered car. Most of today's electric cars are still propelled by lead-acid batteries. General Motors in their prototype Impact, for example, used starting-lighting-ignition batteries, which deliver lots of power for demonstrations, but have a life of less than 100 deep discharges. Now promising alternative technology has challenged the world-wide lead miners, refiners, and battery makers into forming a consortium that sponsors research into making better lead-acid batteries. Horizon's new bipolar battery delivered 50 watt-hours per kg (Wh/kg), compared with 20 for ordinary transport-vehicle batteries. The alternatives are delivering from 80 Wh/kg (nickel-metal hydride) up to 200 Wh/kg (zinc-bromine). A Fiat Panda traveled 260 km on a single charge of its zinc-bromine battery. A German 3.5-ton postal truck traveled 300 km with a single charge in its 650-kg (146 Wh/kg) zinc-air battery. Its top speed was 110 km per hour.

  17. Potassium Secondary Batteries.

    Science.gov (United States)

    Eftekhari, Ali; Jian, Zelang; Ji, Xiulei

    2017-02-08

    Potassium may exhibit advantages over lithium or sodium as a charge carrier in rechargeable batteries. Analogues of Prussian blue can provide millions of cyclic voltammetric cycles in aqueous electrolyte. Potassium intercalation chemistry has recently been demonstrated compatible with both graphite and nongraphitic carbons. In addition to potassium-ion batteries, potassium-O2 (or -air) and potassium-sulfur batteries are emerging. Additionally, aqueous potassium-ion batteries also exhibit high reversibility and long cycling life. Because of potentially low cost, availability of basic materials, and intriguing electrochemical behaviors, this new class of secondary batteries is attracting much attention. This mini-review summarizes the current status, opportunities, and future challenges of potassium secondary batteries.

  18. A desalination battery.

    Science.gov (United States)

    Pasta, Mauro; Wessells, Colin D; Cui, Yi; La Mantia, Fabio

    2012-02-08

    Water desalination is an important approach to provide fresh water around the world, although its high energy consumption, and thus high cost, call for new, efficient technology. Here, we demonstrate the novel concept of a "desalination battery", which operates by performing cycles in reverse on our previously reported mixing entropy battery. Rather than generating electricity from salinity differences, as in mixing entropy batteries, desalination batteries use an electrical energy input to extract sodium and chloride ions from seawater and to generate fresh water. The desalination battery is comprised by a Na(2-x)Mn(5)O(10) nanorod positive electrode and Ag/AgCl negative electrode. Here, we demonstrate an energy consumption of 0.29 Wh l(-1) for the removal of 25% salt using this novel desalination battery, which is promising when compared to reverse osmosis (~ 0.2 Wh l(-1)), the most efficient technique presently available.

  19. A Desalination Battery

    KAUST Repository

    Pasta, Mauro

    2012-02-08

    Water desalination is an important approach to provide fresh water around the world, although its high energy consumption, and thus high cost, call for new, efficient technology. Here, we demonstrate the novel concept of a "desalination battery", which operates by performing cycles in reverse on our previously reported mixing entropy battery. Rather than generating electricity from salinity differences, as in mixing entropy batteries, desalination batteries use an electrical energy input to extract sodium and chloride ions from seawater and to generate fresh water. The desalination battery is comprised by a Na 2-xMn 5O 10 nanorod positive electrode and Ag/AgCl negative electrode. Here, we demonstrate an energy consumption of 0.29 Wh l -1 for the removal of 25% salt using this novel desalination battery, which is promising when compared to reverse osmosis (∼ 0.2 Wh l -1), the most efficient technique presently available. © 2012 American Chemical Society.

  20. Cardiac tamponade (image)

    Science.gov (United States)

    Cardiac tamponade is a condition involving compression of the heart caused by blood or fluid accumulation in the space ... they cannot adequately fill or pump blood. Cardiac tamponade is an emergency condition that requires hospitalization.

  1. What Is Cardiac Rehabilitation?

    Science.gov (United States)

    ANSWERS by heart Treatments + Tests What Is Cardiac Rehabilitation? A cardiac rehabilitation (rehab) program takes place in a hospital or ... special help in making lifestyle changes. During your rehabilitation program you’ll… • Have a medical evaluation to ...

  2. Application of Biomaterials in Cardiac Repair and Regeneration

    Directory of Open Access Journals (Sweden)

    Zhi Cui

    2016-03-01

    Full Text Available Cardiovascular disease is a leading cause of death throughout the world. The demand for new therapeutic interventions is increasing. Although pharmacological and surgical interventions dramatically improve the quality of life of cardiovascular disease patients, cheaper and less invasive approaches are always preferable. Biomaterials, both natural and synthetic, exhibit great potential in cardiac repair and regeneration, either as a carrier for drug delivery or as an extracellular matrix substitute scaffold. In this review, we discuss the current treatment options for several cardiovascular diseases, as well as types of biomaterials that have been investigated as potential therapeutic interventions for said diseases. We especially highlight investigations into the possible use of conductive polymers for correcting ischemic heart disease-induced conduction abnormalities, and the generation of biological pacemakers to improve the conduction pathway in heart block.

  3. Dislocation of a non-functional transvenous ventricular pacemaker lead in a child 6 years following abandonment.

    Science.gov (United States)

    Nagel, Bert; Koestenberger, Martin; Knez, Igor; Gamillscheg, Andreas

    2010-11-01

    This case report describes for the first time a late dislocation of an abandoned transvenous ventricular pacemaker (PM) lead in a child. Further management of this complication and the importance for follow-up of PM leads are discussed.

  4. Polyoxometalate flow battery

    Science.gov (United States)

    Anderson, Travis M.; Pratt, Harry D.

    2016-03-15

    Flow batteries including an electrolyte of a polyoxometalate material are disclosed herein. In a general embodiment, the flow battery includes an electrochemical cell including an anode portion, a cathode portion and a separator disposed between the anode portion and the cathode portion. Each of the anode portion and the cathode portion comprises a polyoxometalate material. The flow battery further includes an anode electrode disposed in the anode portion and a cathode electrode disposed in the cathode portion.

  5. Posicionamento ectópico de eletrodo de marcapasso Posicionamiento ectópico de electrodo de marcapaso Ectopic positioning of pacemaker electrode

    Directory of Open Access Journals (Sweden)

    Gildo Mota

    2010-05-01

    Full Text Available Apresentamos o caso de um paciente portador da forma cardíaca da doença de Chagas com disfunção ventricular esquerda e bloqueio atrioventricular de 2º grau Mobitz II, associados a vários episódios de síncope. Foi submetido a implante de marcapasso artificial definitivo dupla câmara. Após um ano do implante foi diagnosticado deslocamento de eletrodo atrial, sendo submetido a reimplante de eletrodo atrial. Após dois anos do primeiro procedimento cirúrgico, apresentava dispneia aos grandes esforços. Durante a avaliação, foi solicitado ecocardiograma, que detectou a presença de corpo estranho de características metálicas em câmaras cardíacas esquerdas, consistente com eletrodo de marcapasso ectópico.Referimos el caso de un paciente portador de la forma cardíaca de la enfermedad de Chagas con disfunción ventricular izquierda y bloqueo atrioventricular de 2° grado Mobitz II, asociados a varios episodios de síncope. Fue sometido a implante de marcapaso artificial definitivo doble cámara. Tras un año del implante se diagnosticó desplazamiento de electrodo atrial, con la sumisión del paciente a reimplante de electrodo atrial. Tras dos años del primer procedimiento quirúrgico, presentaba disnea a los grandes esfuerzos. Durante la evaluación, se solicitó ecocardiograma, que detectó presencia de cuerpo extraño de características metálicas en cámaras cardíacas izquierdas, de acuerdo con electrodo de marcapaso ectópico.The present case reports on a patient presenting the cardiac form of Chagas disease, with left ventricular dysfunction and second-degree atrioventricular block Mobitz type II, associated with several syncope episodes. The patient underwent a double-chamber definitive artificial pacemaker implant. One year after the implant, the displacement of the atrial electrode was diagnosed and the patient was submitted to re-implantation of the atrial electrode. Two years after the first surgical procedure, the

  6. Electronically configured battery pack

    Energy Technology Data Exchange (ETDEWEB)

    Kemper, D.

    1997-03-01

    Battery packs for portable equipment must sometimes accommodate conflicting requirements to meet application needs. An electronically configurable battery pack was developed to support two highly different operating modes, one requiring very low power consumption at a low voltage and the other requiring high power consumption at a higher voltage. The configurable battery pack optimizes the lifetime and performance of the system by making the best use of all available energy thus enabling the system to meet its goals of operation, volume, and lifetime. This paper describes the cell chemistry chosen, the battery pack electronics, and tradeoffs made during the evolution of its design.

  7. Battery Thermal Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Keyser, Matthew; Saxon, Aron; Powell, Mitchell; Shi, Ying

    2016-06-07

    This poster shows the progress in battery thermal characterization over the previous year. NREL collaborated with U.S. DRIVE and USABC battery developers to obtain thermal properties of their batteries, obtained heat capacity and heat generation of cells under various power profiles, obtained thermal images of the cells under various drive cycles, and used the measured results to validate thermal models. Thermal properties are used for the thermal analysis and design of improved battery thermal management systems to support achieve life and performance targets.

  8. Ballistic negatron battery

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, M.S.R. [Koneru Lakshmiah Univ.. Dept. of Electrical and Electronics Engineering, Green fields, Vaddeswaram (India)

    2012-07-01

    If we consider the Statistics there is drastic increase in dependence of batteries from year to year, due to necessity of power storage equipment at homes, power generating off grid and on grid Wind, PV systems, etc.. Where wind power is leading in renewable sector, there is a need to look at its development. Considering the scenario in India, most of the wind resource areas are far away from grid and the remaining areas which are near to grid are of low wind currents which is of no use connecting these equipment directly to grid. So, there is a need for a power storage utility to be integrated, such as the BNB (Ballistic Negatron Battery). In this situation a country like India need a battery which should be reliable, cheap and which can be industrialized. So this paper presents the concept of working, design, operation, adaptability of a Ballistic Negatron Battery. Unlike present batteries with low energy density, huge size, more weight, more charging time and low resistant to wear level, this Ballistic Negatron Battery comes with, 1) High energy storage capability (many multiples more than the present most advanced battery). 2) Very compact in size. 3) Almost negligible in weight compared to present batteries. 4) Charges with in very less time. 5) Never exhibits a wear level greater than zero. Seems like inconceivable but adoptable with simple physics. This paper will explains in detail the principle, model, design, construction and practical considerations considered in making this battery. (Author)

  9. Cardiac sodium channelopathies

    NARCIS (Netherlands)

    Amin, A.S.; Asghari-Roodsari, A.; Tan, H.L.

    2010-01-01

    Cardiac sodium channel are protein complexes that are expressed in the sarcolemma of cardiomyocytes to carry a large inward depolarizing current (I-Na) during phase 0 of the cardiac action potential. The importance of I-Na for normal cardiac electrical activity is reflected by the high incidence of

  10. Cardiac disease and arrhythmogenesis: Mechanistic insights from mouse models

    Directory of Open Access Journals (Sweden)

    Lois Choy

    2016-09-01

    Full Text Available The mouse is the second mammalian species, after the human, in which substantial amount of the genomic information has been analyzed. With advances in transgenic technology, mutagenesis is now much easier to carry out in mice. Consequently, an increasing number of transgenic mouse systems have been generated for the study of cardiac arrhythmias in ion channelopathies and cardiomyopathies. Mouse hearts are also amenable to physical manipulation such as coronary artery ligation and transverse aortic constriction to induce heart failure, radiofrequency ablation of the AV node to model complete AV block and even implantation of a miniature pacemaker to induce cardiac dyssynchrony. Last but not least, pharmacological models, despite being simplistic, have enabled us to understand the physiological mechanisms of arrhythmias and evaluate the anti-arrhythmic properties of experimental agents, such as gap junction modulators, that may be exert therapeutic effects in other cardiac diseases. In this article, we examine these in turn, demonstrating that primary inherited arrhythmic syndromes are now recognized to be more complex than abnormality in a particular ion channel, involving alterations in gene expression and structural remodelling. Conversely, in cardiomyopathies and heart failure, mutations in ion channels and proteins have been identified as underlying causes, and electrophysiological remodelling are recognized pathological features. Transgenic techniques causing mutagenesis in mice are extremely powerful in dissecting the relative contributions of different genes play in producing disease phenotypes. Mouse models can serve as useful systems in which to explore how protein defects contribute to arrhythmias and direct future therapy.

  11. Cardiac arrhythmias and sudden unexpected death in epilepsy (SUDEP).

    Science.gov (United States)

    Velagapudi, Poonam; Turagam, Mohit; Laurence, Thomas; Kocheril, Abraham

    2012-03-01

    Sudden unexpected death in epilepsy (SUDEP) is a major clinical problem in epilepsy patients in the United States, especially those with chronic, uncontrolled epilepsy. Several pathophysiological events contributing to SUDEP include cardiac arrhythmias, respiratory dysfunction, and dysregulation of systemic or cerebral circulation. There is a significant body of literature suggesting the prominent role of cardiac arrhythmias in the pathogenesis of SUDEP. There is evidence to say that long-standing epilepsy can cause physiological and anatomical autonomic instability resulting in life-threatening arrhythmias. Tachyarrhythmias, bradyarrhythmias, and asystole are commonly seen during ictal, interictal, and postictal phase in epilepsy patients. It is unclear if these rhythm disturbances need attention as some of them may be just benign findings. Evidence regarding prolonged cardiovascular monitoring or the benefit of pacemaker/defibrillator implantation for primary or secondary prevention in epilepsy patients is limited. Awareness regarding pathophysiology, cardiac effects, and management options of SUDEP will become useful in guiding more individualized treatment in the near future. (PACE 2011; 1-8).

  12. Swim pacemaker response to bath applied neurotransmitters in the cubozoan Tripedalia cystophora.

    Science.gov (United States)

    Bielecki, Jan; Nachman, Gösta; Garm, Anders

    2013-09-01

    The four rhopalia of cubomedusae are integrated parts of the central nervous system carrying their many eyes and thought to be the centres of visual information processing. Rhopalial pacemakers control locomotion through a complex neural signal transmitted to the ring nerve and the signal frequency is modulated by the visual input. Since electrical synapses have never been found in the cubozoan nervous system all signals are thought to be transmitted across chemical synapses, and so far information about the neurotransmitters involved are based on immunocytochemical or behavioural data. Here we present the first direct physiological evidence for the types of neurotransmitters involved in sensory information processing in the rhopalial nervous system. FMRFamide, serotonin and dopamine are shown to have inhibitory effect on the pacemaker frequency. There are some indications that the fast acting acetylcholine and glycine have an initial effect and then rapidly desensitise. Other tested neuroactive compounds (GABA, glutamate, and taurine) could not be shown to have a significant effect.

  13. Pacemakers and implantable cardioverter defibrillators, unknown to chest radiography: Review, complications and systematic reading

    Energy Technology Data Exchange (ETDEWEB)

    Alandete Germán, Salvador Pascual, E-mail: salaiger@gmail.com; Isarria Vidal, Santiago, E-mail: isarria@comv.es; Domingo Montañana, María Luisa, E-mail: domingo.luimon@gmail.com; De la vía Oraá, Esperanza, E-mail: esviao82@gmail.com; Vilar Samper, José, E-mail: vilarsamper@gmail.com

    2015-03-15

    Highlights: •Radiologists have an important function in the evaluation of these devices. •We revise their radiological appearances and possible complications. •The knowledge in normal aspects and complications is important for radiologist. •To ensure an accurate reading of the chest x-ray, we present a systematic approach. -- Abstract: Chest X-ray is the imaging technique of choice for an initial study of pacemakers and implantable cardio-defibrillators (ICD). Radiologists have an important role in the evaluation of its initial placement and in the assessment during its follow-up. For this reason, it is necessary to know not only the different existing devices and its components but also the reasons of malfunction or possible complications. The purpose of this article is to do a systematic review of the different types of pacemakers and ICD. We review their usual radiological appearances, the possible complications which might take place and its causes of malfunctioning.

  14. Pacemaker activity and inhibitory neurotransmission in the colon of Ws/Ws mutant rats

    DEFF Research Database (Denmark)

    Albertí, Elena; Mikkelsen, Hanne Birte; Wang, Xuanyu;

    2007-01-01

    and biphasic inhibitory junction potentials both in wild-type and Ws/Ws rats. Apamin-sensitive, likely purinergic, inhibitory innervation was not affected by loss of ICC. Variable presence of nitrergic innervation likely reflects the presence of direct nitrergic innervation to smooth muscle cells as well...... as indirect innervation via ICC. In summary, loss of ICC markedly affects pacemaker and motor activities of the rat colon. Inhibitory innervation is largely maintained but nitrergic innervation is reduced possibly related to the loss of ICC-mediated relaxation.......The aim of this study was to characterize the pacemaker activity and inhibitory neurotransmission in the colon of Ws/Ws mutant rats, which harbor a mutation in the c-kit gene that affects development of interstitial cells of Cajal (ICC). In Ws/Ws rats, the density of KIT-positive cells was markedly...

  15. Exponential synchronization rate of Kuramoto oscillators in the presence of a pacemaker.

    Science.gov (United States)

    Wang, Yongqiang; Doyle, Francis J

    2012-08-27

    The exponential synchronization rate is addressed for Kuramoto oscillators in the presence of a pacemaker. When natural frequencies are identical, we prove that synchronization can be ensured even when the phases are not constrained in an open half-circle, which improves the existing results in the literature. We derive a lower bound on the exponential synchronization rate, which is proven to be an increasing function of pacemaker strength, but may be an increasing or decreasing function of local coupling strength. A similar conclusion is obtained for phase locking when the natural frequencies are non-identical. An approach to trapping phase differences in an arbitrary interval is also given, which ensures synchronization in the sense that synchronization error can be reduced to an arbitrary level.

  16. Permanent cardiac pacing in pediatric patients.

    Science.gov (United States)

    Lotfy, Wael; Hegazy, Ranya; AbdElAziz, Osama; Sobhy, Rodina; Hasanein, Hossam; Shaltout, Fawzan

    2013-02-01

    Pediatric pacemaker (PM) implants comprise less than 1 % of all PM implants. This study aimed to investigate permanent cardiac pacing among the pediatric population, identifying different indications and complications of pediatric cardiac pacing, especially focusing on the effect of the pacing sites, the PM lead type, and the indications for pacing. The current work is a cross-sectional study of 103 procedures for permanent PM insertion in pediatric patients between January 2001 and December 2010. The patients were followed up 1, 3, and 6 months after implantation, then every 6 months or as needed. Evaluation included routine clinical examination, electrocardiography, chest X-ray, echocardiography, and a full analysis of the pacing system measurements. The ages of the patients ranged from 0.09 to 12 years (median, 2.3 years). The most common indication for pacing was postoperative complete heart bock, noted in 54 patients (52.4 %). Transvenous endocardial PM insertion was performed in 92 procedures (89.3 %), whereas transthoracic epicardial insertion was performed in 11 procedures (10.7 %). The most common site of pacing was the right ventricular apex (n = 64, 62 %), followed by the right ventricular outflow tract (n = 25, 24.3 %). Transthoracic epicardial PM insertion was associated with a significantly higher percentage and greater severity of complications. In this study, 65 % of the patients with left ventricle (LV) dilation before pacing showed a significant improvement in LV dimensions and function after pacing. This was noted only in those with endocardially inserted PM leads in both the congenital and the postoperative groups regardless of the pacing site. Endocardial PM insertion in children is a safe procedure with fewer complications and a lower ventricular threshold than the epicardial route. Permanent single-chamber right ventricle pacing is safe and can lead to significant improvement in LV function and dimensions. However, long-term follow

  17. Mechanisms of cardiac pain.

    Science.gov (United States)

    Foreman, Robert D; Garrett, Kennon M; Blair, Robert W

    2015-04-01

    Angina pectoris is cardiac pain that typically is manifested as referred pain to the chest and upper left arm. Atypical pain to describe localization of the perception, generally experienced more by women, is referred to the back, neck, and/or jaw. This article summarizes the neurophysiological and pharmacological mechanisms for referred cardiac pain. Spinal cardiac afferent fibers mediate typical anginal pain via pathways from the spinal cord to the thalamus and ultimately cerebral cortex. Spinal neurotransmission involves substance P, glutamate, and transient receptor potential vanilloid-1 (TRPV1) receptors; release of neurokinins such as nuclear factor kappa b (NF-kb) in the spinal cord can modulate neurotransmission. Vagal cardiac afferent fibers likely mediate atypical anginal pain and contribute to cardiac ischemia without accompanying pain via relays through the nucleus of the solitary tract and the C1-C2 spinal segments. The psychological state of an individual can modulate cardiac nociception via pathways involving the amygdala. Descending pathways originating from nucleus raphe magnus and the pons also can modulate cardiac nociception. Sensory input from other visceral organs can mimic cardiac pain due to convergence of this input with cardiac input onto spinothalamic tract neurons. Reduction of converging nociceptive input from the gallbladder and gastrointestinal tract can diminish cardiac pain. Much work remains to be performed to discern the interactions among complex neural pathways that ultimately produce or do not produce the sensations associated with cardiac pain.

  18. [Subclavian vein puncture as a primary approach for pacemaker lead implantation].

    Science.gov (United States)

    Kronski, D; Haas, H

    2001-12-01

    In the beginning of transvenous pacemaker therapy, the external or alternatively internal jugular vein was commonly used for lead implantation. Due to frequent long-term complications both approaches are nowadays obsolete. In most pacemaker centers implantation via the cephalic vein has become standard. As an alternative, in 1975 Sterz et al. introduced puncture of the subclavian vein in the Seldinger technique as an approach for lead implantation. At this time, the commonly used introducers of pacemaker leads had to be cut for removal. No earlier than 1980 "peel away" introducers were commercially available. Since then, we consequently use this technique for implantation of single or dual chamber pacemaker devices. In the course of the last seven years merely 1.5-2% of implantations were performed via the cephalic vein; no jugular vein approach was performed. Due to a routinely performed subclavian vein puncture, we were able to optimize the procedure, proven by an enormous reduction in implantation time (local anesthesia - skin closure), x-ray time and complication rate. In the year 2000 we performed 52 implantations of a single chamber device with an average fluoroscopy time of 1.5 (0.3-9.3) minutes, radiation dose of 4.5 (0.1-47) Gycm(2) and implantation time of 17.6 (8-40) minutes and 144 implantations of a dual chamber device with an average fluoroscopy time of 2.86 (0.7-6.6) minutes, radiation dose of 8.31 (0.7-28) Gycm(2) and implantation time of 21.25 (10-45) minutes. Complications were rare, clinically irrelevant arterial punctures. Neither nerval damage nor pneumothoraces with the necessity for chest tube placement were seen in the above mentioned time frame. No early or late thrombosis of the subclavian vein was encountered.    The primary subclavian vein approach led to an enormous reduction in overall procedure time without significant morbidity.

  19. Treatment of pacemaker-induced superior vena cava syndrome by balloon angioplasty and stenting.

    LENUS (Irish Health Repository)

    Klop, B

    2011-01-01

    Superior vena cava (SVC) syndrome is a rare but serious complication after pacemaker implantation. This report describes three cases of SVC syndrome treated with venoplasty and venous stenting, with an average follow-up of 30.7 (±3.1) months. These cases illustrate that the definitive diagnosis, and the extent and location of venous obstruction, can only be determined by venography.

  20. Solar dynamo as host power pacemaker of the Earth global climate

    OpenAIRE

    Rusov, Vitaliy D.; Linnik, Elena P.; Vladimir N. Vaschenko; Mavrodiev, Strachimir Cht.; Margarita E. Beglaryan; Zelentsova, Tatiana N.; Tarasov, Victor A.; Litvinov, Dmitriy A.; Smolyar, Vladimir P.; Vachev, Boyko I.

    2011-01-01

    It is known that the so-called problem of solar power pacemaker related to possible existence of some hidden but key mechanism of energy influence of the Sun on fundamental geophysical processes is one of the principal and puzzling problems of modern climatology. The "tracks" of this mechanism have been shown up in different problems of solar-terrestrial physics for a long time and, in particular, in climatology, where the solar-climate variability is stably observed. However, the mechanisms ...

  1. Silicon Betavoltaic Batteries Structures

    Directory of Open Access Journals (Sweden)

    V.N. Murashev

    2015-12-01

    Full Text Available For low-power miniature energy creation sources the particular interest is nickel Ni63. This paper discusses the main types of betavoltaic battery structures with the prospects for industrial application using - isotope of nickel Ni63. It is shown that the prospects for improving the effective efficiency are planar multijunction betavoltaic batteries.

  2. Computing Battery Lifetime Distributions

    NARCIS (Netherlands)

    Cloth, Lucia; Jongerden, Marijn R.; Haverkort, Boudewijn R.

    2007-01-01

    The usage of mobile devices like cell phones, navigation systems, or laptop computers, is limited by the lifetime of the included batteries. This lifetime depends naturally on the rate at which energy is consumed, however, it also depends on the usage pattern of the battery. Continuous drawing of a

  3. Hydrophobic, Porous Battery Boxes

    Science.gov (United States)

    Bragg, Bobby J.; Casey, John E., Jr.

    1995-01-01

    Boxes made of porous, hydrophobic polymers developed to contain aqueous potassium hydroxide electrolyte solutions of zinc/air batteries while allowing air to diffuse in as needed for operation. Used on other types of batteries for in-cabin use in which electrolytes aqueous and from which gases generated during operation must be vented without allowing electrolytes to leak out.

  4. Battery energy storage system

    NARCIS (Netherlands)

    Tol, C.S.P.; Evenblij, B.H.

    2009-01-01

    The ability to store electrical energy adds several interesting features to a ships distribution network, as silent power, peak shaving and a ride through in case of generator failure. Modern intrinsically safe Li-ion batteries bring these within reach. For this modern lithium battery applications t

  5. Battery thermal management unit

    Science.gov (United States)

    Sanders, Nicholas A.

    1989-03-01

    A battery warming device has been designed which uses waste heat from an operating internal combustion engine to warm a battery. A portion of the waste heat is stored in the sensible and latent heat of a phase change type material for use in maintaining the battery temperature after the engine is shut off. The basic design of the device consists of a Phase Change Material (PCM) reservoir and a simple heat exchanger connected to the engineer's cooling system. Two types of units were built, tested and field trialed. A strap-on type which was strapped to the side of an automotive battery and was intended for the automotive after-market and a tray type on which a battery or batteries sat. This unit was intended for the heavy duty truck market. It was determined that both types of units increased the average cranking power of the batteries they were applied to. Although there were several design problems with the units such as the need for an automatic thermostatically controlled bypass valve, the overall feeling is that there is a market opportunity for both the strap-on and tray type battery warming units.

  6. From two competing oscillators to one coupled-clock pacemaker cell system.

    Science.gov (United States)

    Yaniv, Yael; Lakatta, Edward G; Maltsev, Victor A

    2015-01-01

    At the beginning of this century, debates regarding "what are the main control mechanisms that ignite the action potential (AP) in heart pacemaker cells" dominated the electrophysiology field. The original theory which prevailed for over 50 years had advocated that the ensemble of surface membrane ion channels (i.e., "M-clock") is sufficient to ignite rhythmic APs. However, more recent experimental evidence in a variety of mammals has shown that the sarcoplasmic reticulum (SR) acts as a "Ca(2+)-clock" rhythmically discharges diastolic local Ca(2+) releases (LCRs) beneath the cell surface membrane. LCRs activate an inward current (likely that of the Na(+)/Ca(2+) exchanger) that prompts the surface membrane "M-clock" to ignite an AP. Theoretical and experimental evidence has mounted to indicate that this clock "crosstalk" operates on a beat-to-beat basis and determines both the AP firing rate and rhythm. Our review is focused on the evolution of experimental definition and numerical modeling of the coupled-clock concept, on how mechanisms intrinsic to pacemaker cell determine both the heart rate and rhythm, and on future directions to develop further the coupled-clock pacemaker cell concept.

  7. From two competing oscillators to one coupled-clock pacemaker cell system

    Directory of Open Access Journals (Sweden)

    Yael eYaniv

    2015-02-01

    Full Text Available At the beginning of this century, debates regarding what are the main control mechanisms that ignite the action potential (AP in heart pacemaker cells dominated the electrophysiology field. The original theory which prevailed for over 50 years had advocated that the ensemble of surface membrane ion channels (i.e., M clock is sufficient to ignite rhythmic APs. However, more recent experimental evidence in a variety of mammals has shown that the sarcoplasmic reticulum (SR acts as a Ca2+ clock rhythmically discharges diastolic local Ca2+ releases (LCRs beneath the cell surface membrane. LCRs activate an inward current (likely that of the Na+/Ca2+ exchanger that prompts the surface membrane M clock to ignite an AP. Theoretical and experimental evidence has mounted to indicate that this clock crosstalk operates on a beat-to-beat basis and determines both the AP firing rate and rhythm. Our review is focused on the evolution of experimental definition and numerical modeling of the coupled-clock concept, on how mechanisms intrinsic to pacemaker cell determine both the heart rate and rhythm, and on future directions to develop further the coupled-clock pacemaker cell concept.

  8. Involvement of ryanodine receptors in pacemaker Ca2+ oscillation in murine gastric ICC.

    Science.gov (United States)

    Liu, Hong-Nian; Ohya, Susumu; Wang, Jing; Imaizumi, Yuji; Nakayama, Shinsuke

    2005-03-11

    Using a cell cluster preparation from the stomach smooth muscle tissue of mice, we measured intracellular Ca(2+) oscillations in interstitial cells of Cajal (ICCs) in the presence of nifedipine. Pacemaker [Ca(2+)](i) activity in ICCs was significantly suppressed by caffeine application and restored after washout. Application of either ryanodine or FK-506 terminated the pacemaker [Ca(2+)](i) activity irreversibly. Immunostaining of smooth muscle tissue showed that c-Kit-immunopositive cells (that form network-like structure cells in the myenteric plexus, equivalent to ICCs) clearly express ryanodine receptors (RyR). RT-PCR revealed that ICCs (identified with c-Kit-immunoreactivity) predominantly express type 3 RyR (RyR3). Furthermore, the FK-binding proteins 12 and 12.6, both of which would interact with RyR3, were detected. In conclusion, we provide first evidence for the essential contribution of RyR to generating pacemaker activity in gastric motility. Similar mechanisms might account for spontaneous rhythmicity seen in smooth muscle tissues distributed in the autonomic nervous system.

  9. Cesium blockade of delayed outward currents and electrically induced pacemaker activity in mammalian ventricular myocardium.

    Science.gov (United States)

    Meier, C F; Katzung, B G

    1981-05-01

    The effects of Cs+, 5-25 mM, were studied in cat and guinea pig papillary muscles using voltage clamp and current clamp techniques. In solutions containing normal K+, the major effects of Cs+ were depolarization of the resting potential and reduction of the delayed outward current (ixl) between -80 and -20 mV. Both inward and outward portions of the isochronal current voltage relation (l-s clamps) were reduced by extracellular Cs+. This resulted in a substantial reduction of inward rectification and, by subtraction from the normal I-V relationship, the definition of a Cs+-sensitive component of current. Under current clamp conditions, 5-10 mM Cs+ produced a dose-dependent slowing of repetitive firing induced by depolarization. At higher concentrations (25 mM) the resting potential was depolarized and repetitive activity could not be induced by further depolarization. However, release of hyperpolarizing pulses was followed by prolonged bursts of repetitive action potentials, suggesting partial reversal of blockade or participation of another pacemaker process. The experimental results and a numerical simulation show that under readily attainable conditions, reduction in an outward pacemaker current may slow pacemaker activity.

  10. Alcaligenes xylosoxidans endocarditis of a prosthetic valve and pacemaker in a 62-year-old woman.

    Science.gov (United States)

    Sawant, Abhishek C; Srivatsa, Sanjay S; Castro, Luis J

    2013-01-01

    The bacterium Alcaligenes xylosoxidans is known to cause several nosocomial infections; however, it rarely causes endocarditis, which has a very high mortality rate. Early isolation of the infection source and prompt identification of the patient's antibiotic sensitivities are paramount if the infection is to be treated adequately. We present what is apparently only the second documented case of the successful eradication of bioprosthetic valve endocarditis that was caused by pacemaker lead infection with Alcaligenes xylosoxidans. A 62-year-old woman with multiple comorbidities presented with endocarditis of a recently placed bioprosthetic aortic valve. The infection was secondary to pacemaker lead infection. She underwent antibiotic therapy, but an unusual pattern of antibiotic resistance developed. Despite initially adequate therapy, the infection recurred because of virulence induced by antibiotic resistance. Emergent, high-risk surgical treatment involved excising the infected valve and removing the source of the infection (the pacemaker leads). The patient eventually recovered after prolonged antibiotic therapy and close vigilance for recurrent infection. In addition to the patient's case, we discuss the features of this bacteremia and the challenges in its diagnosis.

  11. Re-use of explanted DDD pacemakers as VDD- clinical utility and cost effectiveness.

    Science.gov (United States)

    Namboodiri, K K N; Sharma, Y P; Bali, H K; Grover, A

    2004-01-01

    Re-use of DDD pulse generators explanted from patients died of unrelated causes is associated with an additional cost of two transvenous leads if implanted as DDD itself, and high rate of infection according to some studies. We studied the clinical and economical aspects of reutilization of explanted DDD pacemakers programmed to VDD mode. Out of 28 patients who received VDD pacemaker during the period, October 2000- September 2001 in the Department of Cardiology, PGIMER, Chandigarh, 5 poor patients were implanted with explanted DDD pulse generators programmed to VDD mode. Each implantation was planned and carried out according to a standard protocol. The age ranged from 45 to 75 (mean-61) years. The indications for pacing were complete heart block (4) and second degree AV block (1). The clinical profile, costs and complications, if any were noted and followed up at regular intervals. The results were compared with patients who received new DDD pulse generators during this period. The additional cost for the atrial lead was not required in these patients. None of these patients had any local site infection. Compared to the two-lead system, the single lead system provided more rapid implantation and minimized complications associated with placement of an atrial lead. The explanted DDD pacemaker can be safely reused as VDD mode with same efficacy in selected patient population. This is associated with lower cost and complications compared to reimplantation as DDD itself.

  12. [Competitive pacing in a patient with DDD pacemaker and bigeminal ventricular extrasystoles].

    Science.gov (United States)

    Carbone, Vincenzo; Candelmo, Fiore; Todaro, Chiara; Oreto, Giuseppe

    2008-11-01

    The ECG recorded from a patient with DDD pacemaker showed variable responses of the pacing system to bigeminal ventricular extrasystoles, dependent on the coupling interval of premature beats. For relatively short coupling intervals, the premature spontaneous event was detected by the pacemaker, inhibiting both atrial and ventricular output, and resulting in a relatively long pacing pause. In slightly less premature end-diastolic extrasystoles, in contrast, the pacing system delivered an atrial spike that was superimposed upon the spontaneous premature QRS complex (pseudo-pseudofusion); under these circumstances, the atrial spike was followed, at the end of the programmed atrioventricular interval, by a ventricular spike falling on the extrasystolic T wave apex (competitive ventricular pacing). This phenomenon, however, did not express a sensing malfunction, but was due to post-atrial ventricular blanking (PAVB), a short period initiated by the atrial spike during which ventricular sensing is temporarily disabled, so that no signal can be detected. Finally, whenever premature end-diastolic impulses occurred after PAVB, during the brief interval defined ventricular safety pacing, the spontaneous event was sensed, being followed by an earlier-than-expected ventricular spike, whose prematurity was aimed at avoiding the occurrence of an artificial impulse upon the T wave of extrasystole. In conclusion, despite several not sensed ventricular extrasystoles and competitive pacing, no sensing malfunction was present. This case demonstrates how complex can be the electrocardiographic analysis of a DDD pacemaker, owing to the many complicating phenomena related to this pacing mechanism.

  13. Battery Pack Thermal Design

    Energy Technology Data Exchange (ETDEWEB)

    Pesaran, Ahmad

    2016-06-14

    This presentation describes the thermal design of battery packs at the National Renewable Energy Laboratory. A battery thermal management system essential for xEVs for both normal operation during daily driving (achieving life and performance) and off-normal operation during abuse conditions (achieving safety). The battery thermal management system needs to be optimized with the right tools for the lowest cost. Experimental tools such as NREL's isothermal battery calorimeter, thermal imaging, and heat transfer setups are needed. Thermal models and computer-aided engineering tools are useful for robust designs. During abuse conditions, designs should prevent cell-to-cell propagation in a module/pack (i.e., keep the fire small and manageable). NREL's battery ISC device can be used for evaluating the robustness of a module/pack to cell-to-cell propagation.

  14. Electrolytes for advanced batteries

    Energy Technology Data Exchange (ETDEWEB)

    Blomgren, G.E. [Energizer, Westlake, OH (United States)

    1999-09-01

    The choices of the components of the electrolyte phase for advanced batteries (lithium and lithium ion batteries) are very sensitive to the electrodes which are used. There are also a number of other requirements for the electrolyte phase, which depend on the cell design and the materials chosen for the battery. The difficulty of choice is compounded when the cell is a rechargeable one. This paper looks at each of these requirements and the degree to which they are met for lithium and lithium ion batteries. The discussion is broken into sections on anode or negative electrode stability requirements, cathode or positive electrode stability requirements, conductivity needs, viscosity and wetting requirements. The effects of these properties and interactions on the performance of batteries are also discussed. (orig.)

  15. Critical appraisal of cardiac implantable electronic devices: complications and management

    Directory of Open Access Journals (Sweden)

    Padeletti L

    2011-09-01

    Full Text Available Luigi Padeletti1, Giosuè Mascioli2, Alessandro Paoletti Perini1, Gino Grifoni1, Laura Perrotta1, Procolo Marchese3, Luca Bontempi3, Antonio Curnis31Istituto di Clinica Medica e Cardiologia, Università degli Studi di Firenze, Italia; 2Elettrofisiologia, Istituto Humanitas Gavazzeni, Bergamo, Italia; 3Elettrofisiologia, Spedali Civili, Brescia, ItaliaAbstract: Population aging and broader indications for the implant of cardiac implantable electronic devices (CIEDs are the main reasons for the continuous increase in the use of pacemakers (PMs, implantable cardioverter-defibrillators (ICDs and devices for cardiac resynchronization therapy (CRT-P, CRT-D. The growing burden of comorbidities in CIED patients, the greater complexity of the devices, and the increased duration of procedures have led to an augmented risk of infections, which is out of proportion to the increase in implantation rate. CIED infections are an ominous condition, which often implies the necessity of hospitalization and carries an augmented risk of in-hospital death. Their clinical presentation may be either at pocket or at endocardial level, but they can also manifest themselves with lone bacteremia. The management of these infections requires the complete removal of the device and subsequent, specific, antibiotic therapy. CIED failures are monitored by competent public authorities, that require physicians to alert them to any failures, and that suggest the opportune strategies for their management. Although the replacement of all potentially affected devices is often suggested, common practice indicates the replacement of only a minority of devices, as close follow-up of the patients involved may be a safer strategy. Implantation of a PM or an ICD may cause problems in the patients' psychosocial adaptation and quality of life, and may contribute to the development of affective disorders. Clinicians are usually unaware of the psychosocial impact of implanted PMs and ICDs. The

  16. Synchronization of stochastic Ca²(+) release units creates a rhythmic Ca²(+) clock in cardiac pacemaker cells.

    Science.gov (United States)

    Maltsev, Anna V; Maltsev, Victor A; Mikheev, Maxim; Maltseva, Larissa A; Sirenko, Syevda G; Lakatta, Edward G; Stern, Michael D

    2011-01-19

    In sinoatrial node cells of the heart, beating rate is controlled, in part, by local Ca²(+) releases (LCRs) from the sarcoplasmic reticulum, which couple to the action potential via electrogenic Na(+)/Ca²(+) exchange. We observed persisting, roughly periodic LCRs in depolarized rabbit sinoatrial node cells (SANCs). The features of these LCRs were reproduced by a numerical model consisting of a two-dimensional array of stochastic, diffusively coupled Ca²(+) release units (CRUs) with fixed refractory period. Because previous experimental studies showed that β-adrenergic receptor stimulation increases the rate of Ca²(+) release through each CRU (dubbed I(spark)), we explored the link between LCRs and I(spark) in our model. Increasing the CRU release current I(spark) facilitated Ca²(+)-induced-Ca²(+) release and local recruitment of neighboring CRUs to fire more synchronously. This resulted in a progression in simulated LCR size (from sparks to wavelets to global waves), LCR rhythmicity, and decrease of LCR period that parallels the changes observed experimentally with β-adrenergic receptor stimulation. The transition in LCR characteristics was steeply nonlinear over a narrow range of I(spark), resembling a phase transition. We conclude that the (partial) periodicity and rate regulation of the "Calcium clock" in SANCs are emergent properties of the diffusive coupling of an ensemble of interacting stochastic CRUs. The variation in LCR period and size with I(spark) is sufficient to account for β-adrenergic regulation of SANC beating rate.

  17. [Prevalence and implicated risk factors associated with the exteriorization of cardiac pacemakers: 5 year follow-up].

    Science.gov (United States)

    Argüello-Hurtado, Marco; Guevara-Valdivia, Milton Ernesto; Aranda-Ayala, Zulema Lisbeth; Hernández-Lara, Javier

    2015-01-01

    Introducción: el objetivo de este estudio es establecer la prevalencia y determinar la frecuencia de factores de riesgo de exteriorización de marcapasos definitivos (MPD), en el departamento de Electrofisiología Cardiaca de la UMAE Hospital de Especialidades "Dr. Antonio Fraga Mouret" del Centro Médico Nacional La Raza del Instituto Mexicano del Seguro Social.Métodos: se llevó a cabo un estudio transversal, descriptivo del periodo: septiembre del 2005 a septiembre del 2010, para el análisis de los factores se manejó como casos y controles; se eligieron emparejándose por edad, sexo y presencia, o no, de factores de riesgo. Se realizó el cálculo de medidas de tendencia central (media, mediana y moda), así como pruebas de chi cuadrada, test de Fisher y razón de momios.Resultados: se implantaron 3192 MPD, identificando 83 casos de exteriorizaciones, seleccionando 43 casos para casos y controles, la edad promedio fue de 71 años. Ninguno de los factores de riesgo ni el tipo de técnica quirúrgica presentó significancia estadística.Conclusiones: nuestra prevalencia de exteriorizaciones es del 2.6 %, valores muy similares a los reportes publicados. Ninguno de los factores de riesgo descritos se encuentra presente como causa de exteriorización en nuestra población. El análisis de la técnica quirúrgica utilizada puede ser un factor importante, por lo que se necesitan estudios posteriores.

  18. Characteristics of Gintonin-Mediated Membrane Depolarization of Pacemaker Activity in Cultured Interstitial Cells of Cajal

    Directory of Open Access Journals (Sweden)

    Byung Joo Kim

    2014-08-01

    Full Text Available Background/Aims: Ginseng regulates gastrointestinal (GI motor activity but the underlying components and molecular mechanisms are unknown. We investigated the effect of gintonin, a novel ginseng-derived G protein-coupled lysophosphatidic acid (LPA receptor ligand, on the pacemaker activity of the interstitial cells of Cajal (ICC in murine small intestine and GI motility. Materials and Methods: Enzymatic digestion was used to dissociate ICC from mouse small intestines. The whole-cell patch-clamp configuration was used to record pacemaker potentials and currents from cultured ICC in the absence or presence of gintonin. In vivo effects of gintonin on gastrointestinal (GI motility were investigated by measuring the intestinal transit rate (ITR of Evans blue in normal and streptozotocin (STZ-induced diabetic mice. Results: We investigated the effects of gintonin on pacemaker potentials and currents in cultured ICC from mouse small intestine. Gintonin caused membrane depolarization in current clamp mode but this action was blocked by Ki16425, an LPA1/3 receptor antagonist, and by the addition of GDPβS, a GTP-binding protein inhibitor, into the ICC. To study the gintonin signaling pathway, we examined the effects of U-73122, an active PLC inhibitor, and chelerythrine and calphostin, which inhibit PKC. All inhibitors blocked gintonin actions on pacemaker potentials, but not completely. Gintonin-mediated depolarization was lower in Ca2+-free than in Ca2+-containing external solutions and was blocked by thapsigargin. We found that, in ICC, gintonin also activated Ca2+-activated Cl- channels (TMEM16A, ANO1, but not TRPM7 channels. In vivo, gintonin (10-100 mg/kg, p.o. not only significantly increased the ITR in normal mice but also ameliorated STZ-induced diabetic GI motility retardation in a dose-dependent manner. Conclusions: Gintonin-mediated membrane depolarization of pacemaker activity and ANO1 activation are coupled to the stimulation of GI

  19. Stimulating endogenous cardiac regeneration

    Directory of Open Access Journals (Sweden)

    Amanda eFinan

    2015-09-01

    Full Text Available The healthy adult heart has a low turnover of cardiac myocytes. The renewal capacity, however, is augmented after cardiac injury. Participants in cardiac regeneration include cardiac myocytes themselves, cardiac progenitor cells, and peripheral stem cells, particularly from the bone marrow compartment. Cardiac progenitor cells and bone marrow stem cells are augmented after cardiac injury, migrate to the myocardium, and support regeneration. Depletion studies of these populations have demonstrated their necessary role in cardiac repair. However, the potential of these cells to completely regenerate the heart is limited. Efforts are now being focused on ways to augment these natural pathways to improve cardiac healing, primarily after ischemic injury but in other cardiac pathologies as well. Cell and gene therapy or pharmacological interventions are proposed mechanisms. Cell therapy has demonstrated modest results and has passed into clinical trials. However, the beneficial effects of cell therapy have primarily been their ability to produce paracrine effects on the cardiac tissue and recruit endogenous stem cell populations as opposed to direct cardiac regeneration. Gene therapy efforts have focused on prolonging or reactivating natural signaling pathways. Positive results have been demonstrated to activate the endogenous stem cell populations and are currently being tested in clinical trials. A potential new avenue may be to refine pharmacological treatments that are currently in place in the clinic. Evidence is mounting that drugs such as statins or beta blockers may alter endogenous stem cell activity. Understanding the effects of these drugs on stem cell repair while keeping in mind their primary function may strike a balance in myocardial healing. To maximize endogenous cardiac regeneration,a combination of these approaches couldameliorate the overall repair process to incorporate the participation ofmultiple cell players.

  20. The circadian neuropeptide PDF signals preferentially through a specific adenylate cyclase isoform AC3 in M pacemakers of Drosophila.

    Directory of Open Access Journals (Sweden)

    Laura B Duvall

    Full Text Available The neuropeptide Pigment Dispersing Factor (PDF is essential for normal circadian function in Drosophila. It synchronizes the phases of M pacemakers, while in E pacemakers it decelerates their cycling and supports their amplitude. The PDF receptor (PDF-R is present in both M and subsets of E cells. Activation of PDF-R stimulates cAMP increases in vitro and in M cells in vivo. The present study asks: What is the identity of downstream signaling components that are associated with PDF receptor in specific circadian pacemaker neurons? Using live imaging of intact fly brains and transgenic RNAi, we show that adenylate cyclase AC3 underlies PDF signaling in M cells. Genetic disruptions of AC3 specifically disrupt PDF responses: they do not affect other Gs-coupled GPCR signaling in M cells, they can be rescued, and they do not represent developmental alterations. Knockdown of the Drosophila AKAP-like scaffolding protein Nervy also reduces PDF responses. Flies with AC3 alterations show behavioral syndromes consistent with known roles of M pacemakers as mediated by PDF. Surprisingly, disruption of AC3 does not alter PDF responses in E cells--the PDF-R(+ LNd. Within M pacemakers, PDF-R couples preferentially to a single AC, but PDF-R association with a different AC(s is needed to explain PDF signaling in the E pacemakers. Thus critical pathways of circadian synchronization are mediated by highly specific second messenger components. These findings support a hypothesis that PDF signaling components within target cells are sequestered into "circadian signalosomes," whose compositions differ between E and M pacemaker cell types.

  1. SU-E-T-585: Optically-Stimulated Luminescent Dosimeters for Monitoring Pacemaker Dose in Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Apicello, L [Hofstra University, Hempstead, NY (United States); Riegel, A; Jamshidi, A [North Shore LIJ Health System, Lake Success, NY (United States)

    2015-06-15

    Purpose: A sufficient amount of ionizing radiation can cause failure to components of pacemakers. Studies have shown that permanent damage can occur after a dose of 10 Gy and minor damage to functionality occurs at doses as low as 2 Gy. Optically stimulated thermoluminescent dosimeters (OSLDs) can be used as in vivo dosimeters to predict dose to be deposited throughout the treatment. The purpose of this work is to determine the effectiveness of using OSLDs for in vivo dosimetry of pacemaker dose. Methods: As part of a clinical in vivo dosimetry experience, OSLDs were placed at the site of the pacemaker by the therapist for one fraction of the radiation treatment. OSLD measurements were extrapolated to the total dose to be received by the pacemaker during treatment. A total of 79 measurements were collected from November 2011 to December 2013 on six linacs. Sixty-six (66) patients treated in various anatomical sites had the dose of their pacemakers monitored. Results: Of the 79 measurements recorded, 76 measurements (96 %) were below 2 Gy. The mean and standard deviation were 50.12 ± 76.41 cGy. Of the 3 measurements that exceeded 2 Gy, 2 measurements matched the dose predicted in the treatment plan and 1 was repeated after an unexpectedly high Result. The repeated measurement yielded a total dose less than 2 Gy. Conclusion: This analysis suggests OSLDs may be used for in vivo monitoring of pacemaker dose. Further research should be performed to assess the effect of increased backscatter from the pacemaker device.

  2. Mathematical Storage-Battery Models

    Science.gov (United States)

    Chapman, C. P.; Aston, M.

    1985-01-01

    Empirical formula represents performance of electrical storage batteries. Formula covers many battery types and includes numerous coefficients adjusted to fit peculiarities of each type. Battery and load parameters taken into account include power density in battery, discharge time, and electrolyte temperature. Applications include electric-vehicle "fuel" gages and powerline load leveling.

  3. Clinical management of electromagnetic interferences in patients with pacemakers and implantable cardioverter-defibrillators: review of the literature and focus on magnetic resonance conditional devices.

    Science.gov (United States)

    Corzani, Alessandro; Ziacchi, Matteo; Biffi, Mauro; Allaria, Luca; Diemberger, Igor; Martignani, Cristian; Bratten, Tara; Gardini, Beatrice; Boriani, Giuseppe

    2015-10-01

    The number of cardiac implantable electronic devices (CIEDs) has greatly increased in the last 10 years. Many electronic devices used in daily activities generate electromagnetic interferences (EMIs) that can interact with CIEDs. In clinical practice, it is very important to know the potential sources of EMIs and their effect on CIEDs in order to understand how to manage or mitigate them. A very important source of EMI is magnetic resonance (MR), which is considered nowadays the diagnostic gold standard for different anatomical districts. In this review, we focused on the effects of EMI on CIEDs and on the clinical management. Moreover, we made a clarification about MR and CIEDs.In patients with CIEDs, EMIs may cause potentially serious and even life-threatening complications (inappropriate shocks, device malfunctions, inhibition of pacing in pacemaker-dependent patients) and may rarely dictate device replacement. The association of inappropriate shocks with increased mortality highlights the importance of minimizing the occurrence of EMI. Adequate advice and recommendations about the correct management of EMIs in patients with CIEDs are required to avoid all complications during hospitalization and in daily life. Furthermore, the article focused on actual management about MR and CIEDs.

  4. The tissue velocity imaging and strain rate imaging in the assessment of interatrial electromechanical conduction in patients with sick sinus syndrome before and after pacemaker implantation.

    Science.gov (United States)

    Zheng, Xiaozhi; Ji, Ping; Mao, Hongwei; Hu, Jianqun

    2011-05-01

    Tissue velocity imaging (TVI) and strain rate imaging (SRI) were recently introduced to quantify myocardial mechanical activity in patients receiving cardiac resynchronization therapy. To clear whether atrial-demand-based (AAI) (R) atrial pacing can fully simulate the electromechanical conduction of physiological state and to clarify which one is more appropriate for the assessment of electromechanical activity of the heart between TVI and SRI, 30 normal subjects and 31 patients with sick sinus syndrome (SSS) before and after AAI(R) pacemaker implantation (PI) were investigated in this study. The results showed that the time intervals (ms), P-SRa assessed by SRI (not P-Va assessed by TVI) prolonged step by step from the lateral wall of the right atrium (RA), the interatrial septum (IAS) and the left atrium (LA) in normal subjects(5.01±0.62, 17.05±3.54 and 45.09±12.26, pIAS and LA in patients with SSS before PI (p>0.05), and they were significant longer than those of normal subjects (pIAS to LA. At the same time, the peak velocities and the peak strain rates during atrial contraction also returned to normal values from lower levels. These data suggested that AAI(R) atrial pacing can successfully reverse the abnormal interatrial electromechanical conduction in patients with SSS, and SRI is more appropriate for the assessment of the electromechanical activity of atrial wall than TVI.

  5. Battery Technology Stores Clean Energy

    Science.gov (United States)

    2008-01-01

    Headquartered in Fremont, California, Deeya Energy Inc. is now bringing its flow batteries to commercial customers around the world after working with former Marshall Space Flight Center scientist, Lawrence Thaller. Deeya's liquid-cell batteries have higher power capability than Thaller's original design, are less expensive than lead-acid batteries, are a clean energy alternative, and are 10 to 20 times less expensive than nickel-metal hydride batteries, lithium-ion batteries, and fuel cell options.

  6. Marketing cardiac CT programs.

    Science.gov (United States)

    Scott, Jason

    2010-01-01

    There are two components of cardiac CT discussed in this article: coronary artery calcium scoring (CACS) and coronary computed tomography angiography (CCTA).The distinctive advantages of each CT examination are outlined. In order to ensure a successful cardiac CT program, it is imperative that imaging facilities market their cardiac CT practices effectively in order to gain a competitive advantage in this valuable market share. If patients receive quality care by competent individuals, they are more likely to recommend the facility's cardiac CT program. Satisfied patients will also be more willing to come back for any further testing.

  7. Lithium Sulfuryl Chloride Battery.

    Science.gov (United States)

    Primary batteries , Electrochemistry, Ionic current, Electrolytes, Cathodes(Electrolytic cell), Anodes(Electrolytic cell), Thionyl chloride ...Phosphorus compounds, Electrical conductivity, Calibration, Solutions(Mixtures), Electrical resistance, Performance tests, Solvents, Lithium compounds

  8. High temperature battery. Hochtemperaturbatterie

    Energy Technology Data Exchange (ETDEWEB)

    Bulling, M.

    1992-06-04

    To prevent heat losses of a high temperature battery, it is proposed to make the incoming current leads in the area of their penetration through the double-walled insulating housing as thermal throttle, particularly spiral ones.

  9. Thermal battery degradation mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Missert, Nancy A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brunke, Lyle Brent [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    Diffuse reflectance IR spectroscopy (DRIFTS) was used to investigate the effect of accelerated aging on LiSi based anodes in simulated MC3816 batteries. DRIFTS spectra showed that the oxygen, carbonate, hydroxide and sulfur content of the anodes changes with aging times and temperatures, but not in a monotonic fashion that could be correlated to phase evolution. Bands associated with sulfur species were only observed in anodes taken from batteries aged in wet environments, providing further evidence for a reaction pathway facilitated by H2S transport from the cathode, through the separator, to the anode. Loss of battery capacity with accelerated aging in wet environments was correlated to loss of FeS2 in the catholyte pellets, suggesting that the major contribution to battery performance degradation results from loss of active cathode material.

  10. Battery energy storage technologies

    Science.gov (United States)

    Anderson, Max D.; Carr, Dodd S.

    1993-03-01

    Battery energy storage systems, comprising lead-acid batteries, power conversion systems, and control systems, are used by three main groups: power generating utilities, power distributing utilities, and major power consumers (such as electric furnace foundries). The principal advantages of battery energy storage systems to generating utilities include load leveling, frequency control, spinning reserve, modular construction, convenient siting, no emissions, and investment deferral for new generation and transmission equipment. Power distributing utilities and major power consumers can avoid costly demand changes by discharging their batteries at peak periods and then recharging with lower cost off-peak power (say, at night). Battery energy storage systems are most cost effective when designed for discharge periods of less than 5 h; other systems (for example, pumped water storage) are better suited for longer discharges. It is estimated that by the year 2000 there will be a potential need for 4000 MW of battery energy storage. New construction of five plants totaling 100 MW is presently scheduled for completion by the Puerto Rico Electric Power Authority between 1992 and 1995.

  11. A microdialysis study on pineal melatonin rhythms in rats after an 8-h phase advance : New characteristics of the underlying pacemaker

    NARCIS (Netherlands)

    Drijfhout, WJ; Brons, HF; Oakley, N; Hagan, RM; Westerink, BHC

    1997-01-01

    This study describes the use of the microdialysis technique to elucidate specific properties of the circadian pacemaking system in the hypothalamus, by measurement of melatonin production in the pineal gland. Melatonin has appeared to be a reliable marker of the pacemaker activity, which is influenc

  12. Cardiac Procedures and Surgeries

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Procedures and Surgeries Updated:Sep 16,2016 If you've had ... degree of coronary artery disease (CAD) you have. Cardiac Procedures and Surgeries Angioplasty Also known as Percutaneous Coronary Interventions [PCI], ...

  13. [Advances in cardiac pacing].

    Science.gov (United States)

    de Carranza, María-José Sancho-Tello; Fidalgo-Andrés, María Luisa; Ferrer, José Martínez; Mateas, Francisco Ruiz

    2012-01-01

    This article contains a review of the current status of remote monitoring and follow-up involving cardiac pacing devices and of the latest developments in cardiac resynchronization therapy. In addition, the most important articles published in the last year are discussed.

  14. A Case of Adult-Onset Acute Rheumatic Fever With Long-Lasting Atrioventricular Block Requiring Permanent Pacemaker Implantation.

    Science.gov (United States)

    Oba, Yusuke; Watanabe, Hiroaki; Nishimura, Yoshioki; Ueno, Shuichi; Nagashima, Takao; Imai, Yasushi; Shimpo, Masahisa; Kario, Kazuomi

    2015-01-01

    A 45-year-old hypertensive Japanese woman presented with epigastric pain on inspiration, fever, complete atrioventricular block and polyarthritis. Her antistreptolysin O levels were markedly elevated. A diagnosis of rheumatic fever was made according to the modified Jones criteria. She was prescribed loxoprofen sodium, which was partially effective for her extracardiac clinical symptoms. However, she had syncope due to complete atrioventricular block with asystole longer than 10 seconds. Consequently, we implanted a permanent pacemaker. Although we prescribed prednisolone, the efficacy of which was limited for the patient's conduction disturbance, the complete atrioventricular block persisted. In our systematic review of 12 similar cases, the duration of complete heart block was always transient and there was no case requiring a permanent pacemaker. We thus encountered a very rare case of adult-onset acute rheumatic fever with persistent complete atrioventricular block necessitating permanent pacemaker implantation.

  15. Anesthetic management of a patient with hypertrophic obstructive cardiomyopathy with dual-chamber pacemaker undergoing transurethral resection of the prostate

    Directory of Open Access Journals (Sweden)

    Jain Amit

    2010-01-01

    Full Text Available We describe the anesthetic management of a patient with hypertrophic obstructive cardiomyopathy with dual-chamber pacemaker undergoing transurethral resection of the prostate. Anesthetic challenges included prevention and management of perioperative arrhythmias, maintenance of adequate preload, afterload and heart rate to relieve left ventricular outflow tract obstruction and considerations related to the presence of dual-chamber pacemaker and TURP. We recommend preoperative reprogramming of the DDD pacemaker, avoidance of magnet application during the procedure, application of electrosurgical unit current returning pad to the anterior aspect of the thigh, especially if monopolar cautery is used, use of central venous pressure line for estimation of preload and careful titration of anesthetic drugs to maintain stable hemodynamics.

  16. Membranes as a possible pacemaker of metabolism in cypriniform fish: does phylogeny matter?

    Science.gov (United States)

    Gonzalez, Alex; Pagé, Benoît; Weber, Jean-Michel

    2015-08-01

    The 'membrane pacemaker theory of metabolism' proposes that membranes set metabolic rate by modulating protein activity, and thus purports to explain membrane fatty acid allometry. This relationship has never been tested across species in ectotherms. After accounting for phylogeny, recent analyses have failed to support this theory based on correlations between muscle membrane composition and body mass across mammals. Therefore, the goal of this study was to seek phylogenetically corrected correlations between membrane composition, body mass and calcium-ATPase activity, using 12 species of closely related cypriniform fish (4-5500 g) covering a much narrower genetic scale than in previous tests. The results show that fish membrane unsaturation decreases with mass, but through different mechanisms from those in endotherms: 16:0 replacing 22:6 in muscle and 18:0 replacing 16:1, 18:1 and 18:2 in liver. This shows that allometric patterns differ between endotherms and ectotherms as well as between tissues. After accounting for phylogeny, however, almost all these relationships lose significance except for overall unsaturation. No relationship between calcium-ATPase activity and mass or phospholipid composition was detected. This study shows that membrane unsaturation of cypriniforms decreases with mass, but that genetic cues unrelated to size account for differences in the relative abundance of individual fatty acids. The membrane pacemaker concept accurately predicts general membrane properties such as unsaturation, but fails to explain finer scale allometric patterns. Future examinations of the membrane pacemaker hypothesis will have to take into account that allometric patterns vary between endotherms and ectotherms and between tissues of the same animal class.

  17. Biomaterials for cardiac regeneration

    CERN Document Server

    Ruel, Marc

    2015-01-01

    This book offers readers a comprehensive biomaterials-based approach to achieving clinically successful, functionally integrated vasculogenesis and myogenesis in the heart. Coverage is multidisciplinary, including the role of extracellular matrices in cardiac development, whole-heart tissue engineering, imaging the mechanisms and effects of biomaterial-based cardiac regeneration, and autologous bioengineered heart valves. Bringing current knowledge together into a single volume, this book provides a compendium to students and new researchers in the field and constitutes a platform to allow for future developments and collaborative approaches in biomaterials-based regenerative medicine, even beyond cardiac applications. This book also: Provides a valuable overview of the engineering of biomaterials for cardiac regeneration, including coverage of combined biomaterials and stem cells, as well as extracellular matrices Presents readers with multidisciplinary coverage of biomaterials for cardiac repair, including ...

  18. Mathematical cardiac electrophysiology

    CERN Document Server

    Colli Franzone, Piero; Scacchi, Simone

    2014-01-01

    This book covers the main mathematical and numerical models in computational electrocardiology, ranging from microscopic membrane models of cardiac ionic channels to macroscopic bidomain, monodomain, eikonal models and cardiac source representations. These advanced multiscale and nonlinear models describe the cardiac bioelectrical activity from the cell level to the body surface and are employed in both the direct and inverse problems of electrocardiology. The book also covers advanced numerical techniques needed to efficiently carry out large-scale cardiac simulations, including time and space discretizations, decoupling and operator splitting techniques, parallel finite element solvers. These techniques are employed in 3D cardiac simulations illustrating the excitation mechanisms, the anisotropic effects on excitation and repolarization wavefronts, the morphology of electrograms in normal and pathological tissue and some reentry phenomena. The overall aim of the book is to present rigorously the mathematica...

  19. Apical Ballooning Syndrome (Takotsubo Cardiomyopathy after Permanent Dual-Chamber Pacemaker Implantation

    Directory of Open Access Journals (Sweden)

    Armando Gardini

    2012-01-01

    Full Text Available Apical ballooning syndrome, also called takotsubo cardiomyopathy, has been recently reported. It may mimic acute myocardial infarction and is typically observed in postmenopausal women after stressful events. A 75-year-old female after permanent dual chamber pacemaker implant complained of chest pain with repolarization alterations suggesting acute myocardial ischemia. Echocardiography showed a left ventricle with akinesia of the apical portions and reduced global systolic function. The patient was treated with antithrombotic agents and intravenous nitrates. No coronary lesions were found at angiography. At ventriculography, a typical takotsubo-like shape of the left ventricle was observed. The clinical and echocardiographic picture normalized at discharge.

  20. Swim pacemakers in box jellyfish are modulated by the visual input

    DEFF Research Database (Denmark)

    Garm, Anders Lydik; Bielecki, Jan

    2008-01-01

    A major part of the cubozoan central nervous system is situated in the eye-bearing rhopalia. One of the neuronal output channels from the rhopalia carries a swim pacemaker signal, which has a one-to-one relation with the swim contractions of the bell shaped body. Given the advanced visual system ...... become more homogeneously distributed. A rise in intensity, on the other hand, produces a steep decline in the frequency and makes the ISIs highly variable. These electrophysiological data are correlated with behavioral observations from the natural habitat of the medusae....

  1. COBE battery overview: History, handling, and performance

    Science.gov (United States)

    Yi, Thomas; Tiller, Smith; Sullivan, David

    1991-01-01

    The following topics are presented in viewgraph format: Cosmic Background Explorer (COBE) mission background; battery background and specifications; cell history; battery mechanical/structural design; battery test data; and flowcharts of the various battery approval procedures.

  2. Lithium use in batteries

    Science.gov (United States)

    Goonan, Thomas G.

    2012-01-01

    Lithium has a number of uses but one of the most valuable is as a component of high energy-density rechargeable lithium-ion batteries. Because of concerns over carbon dioxide footprint and increasing hydrocarbon fuel cost (reduced supply), lithium may become even more important in large batteries for powering all-electric and hybrid vehicles. It would take 1.4 to 3.0 kilograms of lithium equivalent (7.5 to 16.0 kilograms of lithium carbonate) to support a 40-mile trip in an electric vehicle before requiring recharge. This could create a large demand for lithium. Estimates of future lithium demand vary, based on numerous variables. Some of those variables include the potential for recycling, widespread public acceptance of electric vehicles, or the possibility of incentives for converting to lithium-ion-powered engines. Increased electric usage could cause electricity prices to increase. Because of reduced demand, hydrocarbon fuel prices would likely decrease, making hydrocarbon fuel more desirable. In 2009, 13 percent of worldwide lithium reserves, expressed in terms of contained lithium, were reported to be within hard rock mineral deposits, and 87 percent, within brine deposits. Most of the lithium recovered from brine came from Chile, with smaller amounts from China, Argentina, and the United States. Chile also has lithium mineral reserves, as does Australia. Another source of lithium is from recycled batteries. When lithium-ion batteries begin to power vehicles, it is expected that battery recycling rates will increase because vehicle battery recycling systems can be used to produce new lithium-ion batteries.

  3. Symptomatic sick sinus syndrome requiring permanent pacemaker implantation in a patient uwith mirror image dextrocardia with situs inversus and infertility.

    Science.gov (United States)

    Kahali, Dhiman; Mandal, Saroj; Mandal, Debasmita; Ghose, Arijit; Kanjilal, Souvik

    2013-01-01

    Situs inversus with dextrocardia is a congenital condition in which the heart is a mirror image of the anatomically normal heart on the right side. A patient presented with the sick sinus syndrome accompanying mirror image dextrocardia which was associated with double superior vena cava and a left sided inferior vena cava A permanent transvenous demand pacemaker was inserted because of repeated episodes of dizziness and a single episode of syncope with ECG showing bradycardia with junctional escape rhythm. Precise knowledge of the venous system and the location of the apex of the right ventricle were necessary prior to permanent pacemaker implantation. Without such knowledge pacing may be technically challenging.

  4. Cardiac tumors: echo assessment.

    Science.gov (United States)

    Mankad, Rekha; Herrmann, Joerg

    2016-12-01

    Cardiac tumors are exceedingly rare (0.001-0.03% in most autopsy series). They can be present anywhere within the heart and can be attached to any surface or be embedded in the myocardium or pericardial space. Signs and symptoms are nonspecific and highly variable related to the localization, size and composition of the cardiac mass. Echocardiography, typically performed for another indication, may be the first imaging modality alerting the clinician to the presence of a cardiac mass. Although echocardiography cannot give the histopathology, certain imaging features and adjunctive tools such as contrast imaging may aid in the differential diagnosis as do the adjunctive clinical data and the following principles: (1) thrombus or vegetations are the most likely etiology, (2) cardiac tumors are mostly secondary and (3) primary cardiac tumors are mostly benign. Although the finding of a cardiac mass on echocardiography may generate confusion, a stepwise approach may serve well practically. Herein, we will review such an approach and the role of echocardiography in the assessment of cardiac masses.

  5. Used batteries - REMINDER

    CERN Document Server

    2006-01-01

    With colder weather drawing in, it is quite likely that older car batteries will fail. On this subject, the Safety Commission wishes to remind everyone that CERN is not responsible for the disposal of used batteries from private vehicles. So please refrain from abandoning them on pavements or around or inside buildings. Used batteries can be disposed of safely, free-of-charge and without any damage to the environment at waste disposal sites (déchetteries) close to CERN in both France (Ain and Haute-Savoie) and in the Canton of Geneva in Switzerland (Cheneviers). Since the average car battery lasts a number of years, this only represents a small effort on your part over the whole lifetime of your vehicle. Most people don't need reminding that car batteries contain concentrated sulphuric acid, which can cause severe burns. Despite this, we frequently find them casually dumped in scrap metal bins! For more information, please contact R. Magnier/SC-GS 160879 We all have a responsibility for safety and th...

  6. A Martian Air Battery Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This project will investigate an entirely new battery chemistry by developing A Martian Air Battery. Specifically the project will explore the concept of a Martian...

  7. Relativity and the mercury battery.

    Science.gov (United States)

    Zaleski-Ejgierd, Patryk; Pyykkö, Pekka

    2011-10-06

    Comparative, fully relativistic (FR), scalar relativistic (SR) and non-relativistic (NR) DFT calculations attribute about 30% of the mercury-battery voltage to relativity. The obtained percentage is smaller than for the lead-acid battery, but not negligible.

  8. Compatibility of temporary pacemaker myocardial pacing leads with magnetic resonance imaging: an ex vivo tissue study.

    Science.gov (United States)

    Pfeil, Alexander; Drobnik, Stefanie; Rzanny, Reinhard; Aboud, Anas; Böttcher, Joachim; Schmidt, Peter; Ortmann, Christian; Mall, Gita; Hekmat, Khosro; Brehm, Bernhard; Reichenbach, Juergen; Mayer, Thomas E; Wolf, Gunter; Hansch, Andreas

    2012-02-01

    The presence of temporary myocardial pacing leads is considered a safety contraindication for magnetic resonance imaging (MRI). The aim of this ex vivo tissue study was to measure the heating effects at the tip of the leads using proton magnetic resonance spectroscopy ((1)HMRS) thermometry. The tissue effects were verified by histological analyses. Pig hearts with implanted temporary pacemaker myocardial pacing leads were examined by whole-body MRI at 1.5 Tesla. The tests were performed either by a sequence with high specific absorption rate (SAR) or by standard clinical sequences with lower SAR. Temperature changes were detected via (1)HMRS thermometry, by monitoring the frequency difference between water protons and the reference signals of N-methyl protons of creatine/phosphocreatine (Cr/PCr) and trimethylamine (TMA). Histology was performed using several staining techniques. Standard low-SAR and high-SAR sequences did not cause significant temperature increases in the myocardial tissue surrounding the implanted leads. There were no histopathological signs of thermal damage around the tips of the leads in any of the hearts or in a control implanted heart not subjected to MRI. The present data suggest that temporary pacemaker myocardial pacing leads may be compatible with MR scanning at 1.5 Tesla. However, further in vivo studies and carefully monitored patient studies are needed before final safety recommendations can be made.

  9. Pacemaker potentials for the periodic burst discharge in the heart ganglion of a stomatopod, Squilla oratoria.

    Science.gov (United States)

    Watanabe, A; Obara, S; Akiyama, T

    1967-03-01

    From somata of the pacemaker neurons in the Squilla heart ganglion, pacemaker potentials for the spontaneous periodic burst discharge are recorded with intracellular electrodes. The electrical activity is composed of slow potentials and superimposed spikes, and is divided into four types, which are: (a) "mammalian heart" type, (b) "slow generator" type, (c) "slow grower" type, and (d) "slow deficient" type. Since axons which are far from the somata do not produce slow potentials, the soma and dendrites must be where the slow potentials are generated. Hyperpolarization impedes generation of the slow potential, showing that it is an electrically excitable response. Membrane impedance increases on depolarization. Brief hyperpolarizing current can abolish the plateau but brief tetanic inhibitory fiber stimulation is more effective for the abolition. A single stimulus to the axon evokes the slow potential when the stimulus is applied some time after a previous burst. Repetitive stimuli to the axon are more effective in eliciting the slow potential, but the depolarization is not maintained on continuous stimulation. Synchronization of the slow potential among neurons is achieved by: (a) the electrotonic connections, with periodic change in resistance of the soma membrane, (b) active spread of the slow potential, and (c) synchronization through spikes.

  10. Atomic Batteries: Energy from Radioactivity

    OpenAIRE

    Kumar, Suhas

    2015-01-01

    With alternate, sustainable, natural sources of energy being sought after, there is new interest in energy from radioactivity, including natural and waste radioactive materials. A study of various atomic batteries is presented with perspectives of development and comparisons of performance parameters and cost. We discuss radioisotope thermal generators, indirect conversion batteries, direct conversion batteries, and direct charge batteries. We qualitatively describe their principles of operat...

  11. High energy density aluminum battery

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Gilbert M.; Paranthaman, Mariappan Parans; Dai, Sheng; Dudney, Nancy J.; Manthiram, Arumugan; McIntyre, Timothy J.; Sun, Xiao-Guang; Liu, Hansan

    2016-10-11

    Compositions and methods of making are provided for a high energy density aluminum battery. The battery comprises an anode comprising aluminum metal. The battery further comprises a cathode comprising a material capable of intercalating aluminum or lithium ions during a discharge cycle and deintercalating the aluminum or lithium ions during a charge cycle. The battery further comprises an electrolyte capable of supporting reversible deposition and stripping of aluminum at the anode, and reversible intercalation and deintercalation of aluminum or lithium at the cathode.

  12. Microfluidic redox battery.

    Science.gov (United States)

    Lee, Jin Wook; Goulet, Marc-Antoni; Kjeang, Erik

    2013-07-01

    A miniaturized microfluidic battery is proposed, which is the first membraneless redox battery demonstrated to date. This unique concept capitalizes on dual-pass flow-through porous electrodes combined with stratified, co-laminar flow to generate electrical power on-chip. The fluidic design is symmetric to allow for both charging and discharging operations in forward, reverse, and recirculation modes. The proof-of-concept device fabricated using low-cost materials integrated in a microfluidic chip is shown to produce competitive power levels when operated on a vanadium redox electrolyte. A complete charge/discharge cycle is performed to demonstrate its operation as a rechargeable battery, which is an important step towards providing sustainable power to lab-on-a-chip and microelectronic applications.

  13. Cardiac Arrest as a Consequence of Air Embolism: A Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Zia Ur Rahman

    2016-01-01

    Full Text Available Air embolism is an infrequent but potentially catastrophic complication. It could be a complication of invasive procedures including surgery, central line placement, positive pressure ventilation, trauma, hemodialysis, pacemaker placement, cardiac ablation, and decompression sickness. Usually, it does not cause any hemodynamic complication. In rare cases, it could lodge in the heart and cause cardiac arrest. We present a case of an 82-year-old white female who underwent computed tomography (CT guided biopsy of right lung pulmonary nodule. When she was turned over after the lung biopsy, she became unresponsive and developed cardiopulmonary arrest. She underwent successful resuscitation and ultimately was intubated. CT chest was performed immediately after resuscitation which showed frothy air dense material in the left atrium and one of the right pulmonary veins suggesting a Broncho venous fistula with air embolism. Although very rare, air embolism could be catastrophic resulting in cardiac arrest. Supportive care including mechanical ventilation, vasopressors, volume resuscitation, and supplemental oxygen is the initial management. Patients with cardiac, neurological, or respiratory complications benefit from hyperbaric oxygen therapy.

  14. Batteries, from Cradle to Grave

    Science.gov (United States)

    Smith, Michael J.; Gray, Fiona M.

    2010-01-01

    As battery producers and vendors, legislators, and the consumer population become aware of the consequences of inappropriate disposal of batteries to landfill sites instead of responsible chemical neutralization and reuse, the topic of battery recycling has begun to appear on the environmental agenda. In the United Kingdom, estimates of annual…

  15. Battery switch for downhole tools

    Science.gov (United States)

    Boling, Brian E.

    2010-02-23

    An electrical circuit for a downhole tool may include a battery, a load electrically connected to the battery, and at least one switch electrically connected in series with the battery and to the load. The at least one switch may be configured to close when a tool temperature exceeds a selected temperature.

  16. Molecular Basis of Cardiac Myxomas

    Directory of Open Access Journals (Sweden)

    Pooja Singhal

    2014-01-01

    Full Text Available Cardiac tumors are rare, and of these, primary cardiac tumors are even rarer. Metastatic cardiac tumors are about 100 times more common than the primary tumors. About 90% of primary cardiac tumors are benign, and of these the most common are cardiac myxomas. Approximately 12% of primary cardiac tumors are completely asymptomatic while others present with one or more signs and symptoms of the classical triad of hemodynamic changes due to intracardiac obstruction, embolism and nonspecific constitutional symptoms. Echocardiography is highly sensitive and specific in detecting cardiac tumors. Other helpful investigations are chest X-rays, magnetic resonance imaging and computerized tomography scan. Surgical excision is the treatment of choice for primary cardiac tumors and is usually associated with a good prognosis. This review article will focus on the general features of benign cardiac tumors with an emphasis on cardiac myxomas and their molecular basis.

  17. Automotive battery technology

    CERN Document Server

    Watzenig, Daniel

    2014-01-01

    The use of electrochemical energy storage systems in automotive applications also involves new requirements for modeling these systems, especially in terms of model depth and model quality. Currently, mainly simple application-oriented models are used to describe the physical behavior of batteries. This book provides a step beyond of state-of-the-art modeling showing various different approaches covering following aspects: system safety, misuse behavior (crash, thermal runaway), battery state estimation and electrochemical modeling with the needed analysis (pre/post mortem). All this different approaches are developed to support the overall integration process from a multidisciplinary point-of-view and depict their further enhancements to this process.

  18. Lithium-ion batteries

    CERN Document Server

    Yoshio, Masaki; Kozawa, Akiya

    2010-01-01

    This book is a compilation of up-to-date information relative to Li-Ion technology. It provides the reader with a single source covering all important aspects of Li-Ion battery operations. It fills the gap between the old original Li-Ion technology and present state of the technology that has developed into a high state of practice. The book is designed to provide a single source for an up-to-date description of the technology associated with the Li-Ion battery industry. It will be useful to researchers interested in energy conversion for the direct conversion of chemical energy into electrica

  19. Treatment and prevention of acute cardiac tamponade during cardiac interventional therapy%心脏介入术中急性心包填塞的救治

    Institute of Scientific and Technical Information of China (English)

    邢适颖; 王红雷; 董平栓

    2011-01-01

    Objective To provide clinical experience in the treatment and prevention of complicated acute cardiac tamponade in the course of heart interventional therapy. Methods To analyse the clinical features of patients with acute cardiac tamponade and to investigate the possible underlying mechanism. Results Twenty-one cases experienced acute cardiac tamponade when undergoing heart interventional therapy. Among all the 21 patients with acute cardiac tamponade, 11 occurred from percutaneous coronary interention(PCI) ,6 from the radiofrequency catheter ablation , 1 from the closure of atrial rspetal with amplaty closure service, 1 from the percutaeous balloon mitral valvuloplasty ( PBMV), 2 from temporary pacemaker implantation. Eighteen patients were successfully rescued left no serious sequelae. Three cased died, including two PCI-related death and one temporary-pacemaker-installation-related death. Conclusion Any heart interventional operation is at the risk to cause acute cardiac tamponade. Early identification and appropriate treatment is the key to successful rescue.%目的 探讨心脏介入治疗过程中急性心包填塞的临床救治.方法 对21例心脏介入性操作相关的急性心包填塞患者临床资料进行回顾性分析.结果 21例急性心包填塞患者,其中行经皮冠状动脉介入治疗(PCI)11例;射频消融术6例;房间隔缺损封堵术1例;二尖瓣球囊扩张术(PBMV)1例;临时起搏器安装术2例.抢救成功18例,未遗留严重后遗症.死亡3例,2例为PCI相关的急性心包填塞,l例为临时起搏器安装导致.结论 任何心脏介入性操作都可能引起急性心包填塞,早期识别和果断处理是成功救治的关键.

  20. Cardiac Tumors; Tumeurs cardiaques

    Energy Technology Data Exchange (ETDEWEB)

    Laissy, J.P.; Fernandez, P. [Centre Hospitalier Universitaire Bichat Claude Bernard, Service d' Imagerie, 76 - Rouen (France); Mousseaux, E. [Hopital Europeen Georges Pompidou (HEGP), Service de Radiologie Cardio Vasculaire et Interventionnelle, 75 - Paris (France); Dacher, J.N. [Centre Hospitalier Universitaire Charles Nicolle, 75 - Rouen (France); Crochet, D. [Centre Hospitalier Universitaire, Hopital Laennec, Centre Hemodynamique, Radiologie Thoracique et Vasculaire, 44 - Nantes (France)

    2004-04-01

    Metastases are the most frequent tumors of the heart even though they seldom are recognized. Most primary cardiac tumors are benign. The main role of imaging is to differentiate a cardiac tumor from thrombus and rare pseudo-tumors: tuberculoma, hydatid cyst. Echocardiography is the fist line imaging technique to detect cardiac tumors, but CT and MRl arc useful for further characterization and differential diagnosis. Myxoma of the left atrium is the most frequent benign cardiac tumor. It usually is pedunculated and sometimes calcified. Sarcoma is the most frequent primary malignant tumor and usually presents as a sessile infiltrative tumor. Lymphoma and metastases are usually recognized by the presence of known tumor elsewhere of by characteristic direct contiguous involvement. Diagnosing primary and secondary pericardial tumors often is difficult. Imaging is valuable for diagnosis, characterization, pre-surgical evaluation and follow-up. (author)

  1. Socially differentiated cardiac rehabilitation

    DEFF Research Database (Denmark)

    Meillier, Lucette Kirsten; Nielsen, Kirsten Melgaard; Larsen, Finn Breinholt;

    2012-01-01

    to a standard rehabilitation programme (SRP). If patients were identified as socially vulnerable, they were offered an extended version of the rehabilitation programme (ERP). Excluded patients were offered home visits by a cardiac nurse. Concordance principles were used in the individualised programme elements......%. Patients were equally distributed to the SRP and the ERP. No inequality was found in attendance and adherence among referred patients. Conclusions: It seems possible to overcome unequal referral, attendance, and adherence in cardiac rehabilitation by organisation of systematic screening and social......Aim: The comprehensive cardiac rehabilitation (CR) programme after myocardial infarction (MI) improves quality of life and results in reduced cardiac mortality and recurrence of MI. Hospitals worldwide face problems with low participation rates in rehabilitation programmes. Inequality...

  2. Cardiac arrest - cardiopulmonary resuscitation

    Institute of Scientific and Technical Information of China (English)

    Basri Lenjani; Besnik Elshani; Nehat Baftiu; Kelmend Pallaska; Kadir Hyseni; Njazi Gashi; Nexhbedin Karemani; Ilaz Bunjaku; Taxhidin Zaimi; Arianit Jakupi

    2014-01-01

    Objective:To investigate application of cardiopulmonary resuscitation(CPR) measures within the golden minutes inEurope.Methods:The material was taken from theUniversityClinical Center ofKosovo -EmergencyCentre inPristina, during the two(2) year period(2010-2011).The collected date belong to the patients with cardiac arrest have been recorded in the patients' log book protocol at the emergency clinic.Results:During the2010 to2011 in the emergency center of theCUCK inPristina have been treated a total of269 patients with cardiac arrest, of whom159 or59.1% have been treated in2010, and110 patients or40.9% in2011.Of the269 patients treated in the emergency centre,93 or34.6% have exited lethally in the emergency centre, and176 or 65.4% have been transferred to other clinics.In the total number of patients with cardiac arrest, males have dominated with186 cases, or69.1%.The average age of patients included in the survey was56.7 year oldSD±16.0 years.Of the269 patients with cardiac arrest, defibrillation has been applied for93 or34.6% of patients.In the outpatient settings defibrillation has been applied for3 or3.2% of patients.Patients were defibrillated with application of one to four shocks. Of27 cases with who have survived cardiac arrest, none of them have suffered cardiac arrest at home,3 or11.1% of them have suffered cardiac arrest on the street, and24 or88.9% of them have suffered cardiac arrest in the hospital.5 out of27 patients survived have ended with neurological impairment.Cardiac arrest cases were present during all days of the week, but frequently most reported cases have been onMonday with32.0% of cases, and onFriday with24.5% of cases. Conclusions:All survivors from cardiac arrest have received appropriate medical assistance within10 min from attack, which implies that if cardiac arrest occurs near an institution health care(with an opportunity to provide the emergent health care) the rate of survival is higher.

  3. Cardiac imaging in adults

    Energy Technology Data Exchange (ETDEWEB)

    Jaffe, C.C.

    1987-01-01

    This book approaches adult cardiac disease from the correlative imaging perspective. It includes chest X-rays and angiographs, 2-dimensional echocardiograms with explanatory diagrams for clarity, plus details on digital radiology, nuclear medicine techniques, CT and MRI. It also covers the normal heart, valvular heart disease, myocardial disease, pericardial disease, bacterial endocarditis, aortic aneurysm, cardiac tumors, and congenital heart disease of the adult. It points out those aspects where one imaging technique has significant superiority.

  4. Port Access Cardiac Surgery.

    Science.gov (United States)

    Viganó, Mario; Minzioni, Gaetano; Spreafico, Patrizio; Rinaldi, Mauro; Pasquino, Stefano; Ceriana, Piero; Locatelli, Alessandro

    2000-10-01

    The port-access technique for cardiac surgery was recently developed at Stanford University in California as a less invasive method to perform some cardiac operations. The port-access system has been described in detail elsewhere. It is based on femoral arterial and venous access for cardiopulmonary bypass (CPB) and on the adoption of a specially designed triple-lumen catheter described originally by Peters, and subsequently modified and developed in the definitive configuration called the endoaortic clamp.

  5. Awareness in cardiac anesthesia.

    LENUS (Irish Health Repository)

    Serfontein, Leon

    2010-02-01

    Cardiac surgery represents a sub-group of patients at significantly increased risk of intraoperative awareness. Relatively few recent publications have targeted the topic of awareness in this group. The aim of this review is to identify areas of awareness research that may equally be extrapolated to cardiac anesthesia in the attempt to increase understanding of the nature and significance of this scenario and how to reduce it.

  6. Post cardiac injury syndrome

    DEFF Research Database (Denmark)

    Nielsen, S L; Nielsen, F E

    1991-01-01

    The post-pericardiotomy syndrome is a symptom complex which is similar in many respects to the post-myocardial infarction syndrome and these are summarized under the diagnosis of the Post Cardiac Injury Syndrome (PCIS). This condition, which is observed most frequently after open heart surgery, i...... on the coronary vessels, with cardiac tamponade and chronic pericardial exudate. In the lighter cases, PCIS may be treated with NSAID and, in the more severe cases, with systemic glucocorticoid which has a prompt effect....

  7. Autonomic cardiac innervation

    OpenAIRE

    Hasan, Wohaib

    2013-01-01

    Autonomic cardiac neurons have a common origin in the neural crest but undergo distinct developmental differentiation as they mature toward their adult phenotype. Progenitor cells respond to repulsive cues during migration, followed by differentiation cues from paracrine sources that promote neurochemistry and differentiation. When autonomic axons start to innervate cardiac tissue, neurotrophic factors from vascular tissue are essential for maintenance of neurons before they reach their targe...

  8. Infected cardiac hydatid cyst

    OpenAIRE

    Ceviz, M; Becit, N; Kocak, H.

    2001-01-01

    A 24 year old woman presented with chest pain and palpitation. The presence of a semisolid mass—an echinococcal cyst or tumour—in the left ventricular apex was diagnosed by echocardiography, computed tomography, and magnetic resonance imaging. The infected cyst was seen at surgery. The cyst was removed successfully by using cardiopulmonary bypass with cross clamp.


Keywords: cardiac hydatid cyst; infected cardiac hydatid cyst

  9. Calculation of buffer batteries with voltage-adding storage batteries

    Energy Technology Data Exchange (ETDEWEB)

    Boldin, R.V.; Koloskov, A.A.; Ratner, G.B.; Sharov, V.N.

    1982-01-01

    A technique is proposed for buffer storage batteries of the NKG type with voltage-adding storage batteries. These batteries (B) guarantee comparatively narrow range of change in the voltage for load with discharge of the storage batteries of the main B to the assigned minimum voltage. The purpose of the calculation is to determine the number of voltage-adding B and the number of storage batteries in each of them. The initial data for calculation are minimum and maximum values of voltage for load and storage batteries of the main B. Expressions have been obtained for determining the depth of the discharge and the final expression for determining the depth of the discharge and the final discharge voltage of the storage batteries of each voltage-adding B. The necessary formulas are presented and the order for making the calculation is given.

  10. Video-assisted thoracoscopic implantation of a diaphragmatic pacemaker in a child with tetraplegia: indications, technique, and results

    Directory of Open Access Journals (Sweden)

    Darcy Ribeiro Pinto Filho

    2015-02-01

    Full Text Available We report the case of a child with tetraplegia after cervical trauma, who subsequently underwent diaphragmatic pacemaker implantation. We reviewed the major indications for diaphragmatic pacing and the types of devices employed. We highlight the unequivocal benefit of diaphragmatic pacing in the social and educational reintegration of individuals with tetraplegia.

  11. Pacemaker shift in the gastric antrum of guinea-pigs produced by excitatory vagal stimulation involves intramuscular interstitial cells.

    Science.gov (United States)

    Hirst, G D S; Dickens, E J; Edwards, F R

    2002-06-15

    Intracellular recordings were made from isolated bundles of the circular muscle layer of guinea-pig gastric antrum and the responses produced by stimulating intrinsic nerve fibres were examined. After abolishing the effects of stimulating inhibitory nerve terminals with apamin and L-nitroarginine (NOLA), transmural nerve stimulation often evoked a small amplitude excitatory junction potential (EJP) and invariably evoked a regenerative potential. Neurally evoked regenerative potentials had similar properties to those evoked in the same bundle by direct stimulation. EJPs and neurally evoked regenerative potentials were abolished by hyoscine suggesting that both resulted from the release of acetylcholine and activation of muscarinic receptors. Neurally evoked regenerative potentials, but not EJPs, were abolished by membrane hyperpolarization, caffeine and chloride channel blockers. In the intact antrum, excitatory vagal nerve stimulation increased the frequency of slow waves. Simultaneous intracellular recordings of pacemaker potentials from myenteric interstitial cells (ICC(MY)) and slow waves showed that the onset of each pacemaker potential normally preceded the onset of each slow wave but vagal stimulation caused the onset of each slow wave to precede each pacemaker potential. Together the observations suggest that during vagal stimulation there is a change in the origin of pacemaker activity with slow waves being initiated by intramuscular interstitial cells (ICC(IM)) rather than by ICC(MY).

  12. Risk of pacemaker or implantable cardioverter defibrillator after radiotherapy for early-stage breast cancer in Denmark, 1982-2005

    DEFF Research Database (Denmark)

    Rehammar, Jens Christian; Johansen, Jens Brock; Jensen, Maj-Britt;

    2016-01-01

    (RT). MATERIAL AND METHODS: All women treated for early-stage BC in Denmark from 1982 to 2005 were identified from the Danish Breast Cancer Cooperative Group. By record linkage to the Danish Pacemaker and ICD Registry information was retrieved on CIED implants subsequent to RT. Standardized incidence...

  13. Cardiac device implantation in Fabry disease

    Science.gov (United States)

    Sené, Thomas; Lidove, Olivier; Sebbah, Joel; Darondel, Jean-Marc; Picard, Hervé; Aaron, Laurent; Fain, Olivier; Zenone, Thierry; Joly, Dominique; Charron, Philippe; Ziza, Jean-Marc

    2016-01-01

    Abstract The incidence and predictive factors of arrhythmias and/or conduction abnormalities (ACAs) requiring cardiac device (CD) implantation are poorly characterized in Fabry disease (FD). The aim of our retrospective study was to determine the prevalence, incidence, and factors associated with ACA requiring CD implantation in a monocentric cohort of patients with confirmed FD who were followed up in a department of internal medicine and reference center for FD. Forty-nine patients (20M, 29F) were included. Nine patients (4M, 5F; 18%) had at least one episode of ACA leading to device therapy. Six patients (4M/2F) required a pacemaker (PM) for sinus node dysfunction (n = 4) or atrioventricular disease (n = 2). One female patient required an internal cardioverter-defibrillator (ICD) to prevent sudden cardiac death because of nonsustained ventricular tachycardia (nSVT). One female patient required PM-ICD for sinus node dysfunction and nSVT. One patient underwent CD implantation before the diagnosis of FD. The annual rate of CD implantation was estimated at 1.90 per 100 person years. On univariate analysis at the end of the follow-up period, the factors associated with ACAs requiring CD implantation were as follows: delayed diagnosis of FD, delayed initiation of enzyme replacement therapy, age at the last follow-up visit, and severe multiorgan phenotype (hypertrophic cardiomyopathy, chronic kidney disease, and/or sensorineural hearing loss). On multivariate analysis, age at diagnosis of FD and age at the last follow-up visit were independently associated with an increased risk of ACAs requiring CD (P sudden death in patients with FD, regular monitoring is mandatory, especially in patients with a late diagnosis of FD and/or with a severe phenotype. Regular Holter ECGs, therapeutic education of patients, and deliverance of an emergency card including a phenotype summary are crucial in the care of FD patients. Available guidelines for device therapy and the

  14. Cardiac applications of optogenetics.

    Science.gov (United States)

    Ambrosi, Christina M; Klimas, Aleksandra; Yu, Jinzhu; Entcheva, Emilia

    2014-08-01

    In complex multicellular systems, such as the brain or the heart, the ability to selectively perturb and observe the response of individual components at the cellular level and with millisecond resolution in time, is essential for mechanistic understanding of function. Optogenetics uses genetic encoding of light sensitivity (by the expression of microbial opsins) to provide such capabilities for manipulation, recording, and control by light with cell specificity and high spatiotemporal resolution. As an optical approach, it is inherently scalable for remote and parallel interrogation of biological function at the tissue level; with implantable miniaturized devices, the technique is uniquely suitable for in vivo tracking of function, as illustrated by numerous applications in the brain. Its expansion into the cardiac area has been slow. Here, using examples from published research and original data, we focus on optogenetics applications to cardiac electrophysiology, specifically dealing with the ability to manipulate membrane voltage by light with implications for cardiac pacing, cardioversion, cell communication, and arrhythmia research, in general. We discuss gene and cell delivery methods of inscribing light sensitivity in cardiac tissue, functionality of the light-sensitive ion channels within different types of cardiac cells, utility in probing electrical coupling between different cell types, approaches and design solutions to all-optical electrophysiology by the combination of optogenetic sensors and actuators, and specific challenges in moving towards in vivo cardiac optogenetics.

  15. New mutation of the desmin gene identified in an extended Indian pedigree presenting with distal myopathy and cardiac disease

    Directory of Open Access Journals (Sweden)

    Atchayaram Nalini

    2013-01-01

    Full Text Available In this report, we describe a new mutation located in the coiled 1B domain of desmin and associated with a predominant cardiac involvement and a high degree of cardiac sudden death in a large Indian pedigree with 12 affected members. The index cases was 38-year-old man who presented with progressive difficulty in gripping footwear of 5 years duration with the onset in the left lower limb followed by right lower limb in 6 months. 3 years from onset, he developed lower limb proximal and truncal muscle weakness. There was mild atrophy of the shoulder girdle muscles with grade 3 weakness, moderate wasting of thigh and anterior leg muscles with proximal muscle weakness and foot drop. At 40 years, he had a pacemaker implanted. The 9 exons and intronic boundaries of the desmin gene were sequenced and a heterozygous nucleotide change c. 734A > G in exon 3 was identified.

  16. Characteristics of the Cholecystokinin-Induced Depolarization of Pacemaking Activity in Cultured Interstitial Cells of Cajal from Murine Small Intestine

    Directory of Open Access Journals (Sweden)

    Jae Hwa Lee

    2013-04-01

    Full Text Available Background/Aims: In this study, we studied the effects of cholecystokinin (CCK on pacemaker potentials in cultured interstitial cells of Cajal (ICCs from mouse small intestine using the whole cell patch clamp technique. Methods: ICCs are pacemaker cells that exhibit periodic spontaneous depolarization, which is responsible for the production of slow waves in gastrointestinal smooth muscle, and generate periodic pacemaker potentials in current-clamp mode. Results: Exposure to CCK (100 nM-5 µM decreased the amplitudes of pacemaker potentials and depolarized resting membrane potentials. To identify the type of CCK receptors involved in ICCs, we examined the effects of CCK agonists and found that the addition of CCK1 agonist (A-71323, 1 µM depolarized resting membrane potentials, whereas exposure to CCK2 agonist (gastrin , 1 µM had no effect on pacemaker potentials. To confirm these results, we examined the effects of CCK antagonists and found that pretreatment with CCK1 antagonist (SR 27897, 1 µM blocked CCK-induced effects. However, pretreatment with CCK2 antagonist (LY 225910, 1 µM did not. Furthermore, intracellular GDPβS suppressed CCK-induced effects. To investigate the involvements of phospholipase C (PLC, protein kinase C (PKC, and protein kinase A (PKA in the effects of CCK in cultured ICCs, we used U-73122 (an active PLC inhibitor, chelerythrine (a PKC inhibitor, SQ-22536 (an inhibitor of adenylate cyclase, or mPKAI (an inhibitor of myristoylated PKA. All inhibitors blocked the CCK-mediated effects on pacemaker potentials. In addition, we found that transient receptor potential classical 5 (TRPC5 channel was involved in CCK-activated currents in cultured ICCs. Conclusion: These results suggest that the CCK induced depolarization of pacemaking activity occurs in a G-protein-, PLC-, PKC-, and PKA-dependent manner via CCK1 receptor and TRPC5 channel is a candidate for CCK-activated currents in cultured ICCs in murine small intestine

  17. Campylobacter fetus infection presenting with bacteremia and cellulitis in a 72-year-old man with an implanted pacemaker: a case report

    Directory of Open Access Journals (Sweden)

    Ledina Dragan

    2012-11-01

    Full Text Available Abstract Introduction Campylobacter is an important causative agent of intestinal infections in humans. Bacteremia is detected in less than 1% of patients, mainly in immunocompromised patients and in extreme age groups. Cellulitis is a relatively common manifestation of Campylobacter infection, but concomitant bacteremia is a rare event. Infections of the pacemaker area are caused primarily by staphylococci, followed by fungi, streptococci and Gram-negative rods. To the best of our knowledge, this is the first case report of pacemaker pocket infection and bacteremia caused by Campylobacter fetus. Case presentation A 72-year-old Croatian Caucasian man with myelodysplasia, impaired fasting glucose levels and a recently implanted permanent pacemaker was admitted to hospital after six days of fever, development of red swelling of the pacemaker pocket area and worsening of his general condition. No antibiotic therapy was introduced in the outpatient setting. He denied any recent gastrointestinal disturbances. With the exception of an elevated leukocyte count, erythrocyte sedimentation rate, and C-reactive protein and blood glucose levels, other laboratory findings were normal. Treatment with vancomycin plus netilmicin was introduced, and a surgical incision with drainage of the pacemaker pocket was performed. The entire pacemaker system was removed and a new one re-implanted after 14 days of antibiotic therapy. Transesophageal echocardiography showed no pathological findings. Three subsequent blood cultures obtained on admission as well as swab culture of the incised pacemaker area revealed Campylobacter fetus; stool and pacemaker lead cultures were negative. According to the microbiological results, antibiotic therapy was changed to ciprofloxacin plus netilmicin. A clinical examination and the results of a laboratory analysis performed after two weeks of therapy were within normal limits. Conclusion Myelodysplasia, impaired fasting glucose levels

  18. High energy battery. Hochenergiebatterie

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, H.; Beyermann, G.; Bulling, M.

    1992-03-26

    In a high energy battery with a large number of individual cells in a housing with a cooling medium flowing through it, it is proposed that the cooling medium should be guided so that it only affects one or both sides of the cells thermally.

  19. Secondary alkaline batteries

    Science.gov (United States)

    McBreen, J.

    1984-03-01

    The overall reactions (charge/discharge characteristics); electrode structures and materials; and cell construction are studied for nickel oxide-cadmium, nickel oxide-iron, nickel oxide-hydrogen, nickel oxide-zinc, silver oxide-zinc, and silver oxide-cadmium, silver oxide-iron, and manganese dioxide-zinc batteries.

  20. Remote RF Battery Charging

    NARCIS (Netherlands)

    Visser, H.J.; Pop, V.; Op het Veld, J.H.G.; Vullers, R.J.M.

    2011-01-01

    The design of a remote RF battery charger is discussed through the analysis and design of the subsystems of a rectenna (rectifying antenna): antenna, rectifying circuit and loaded DC-to-DC voltage (buck-boost) converter. Optimum system power generation performance is obtained by adopting a system in

  1. USED BATTERIES-REMINDER

    CERN Multimedia

    2002-01-01

    Note from the TIS Division: Although it is not an obligation for CERN to collect, store and dispose of used batteries from private vehicles, they are often found abandoned on the site and even in the scrap metal bins. As well as being very dangerous (they contain sulphuric acid which is highly corrosive), this practise costs CERN a non-negligible amount of money to dispose of them safely. The disposal of used batteries in the host state could not be simpler, there are 'déchetteries' in neighbouring France at Saint-Genis, Gaillard and Annemasse as well as in other communes. In Geneva Canton the centre de traitement des déchets spéciaux, at Cheneviers on the river Rhône a few kilometers from CERN, will dispose of your batterie free of charge. So we ask you to use a little common sense and to help protect the environnement from the lead and acid in these batteries and even more important, to avoid the possibility of a colleague being seriously injured. It doesn't take m...

  2. Batteries: Imaging degradation

    Science.gov (United States)

    Shearing, Paul R.

    2016-11-01

    The degradation and failure of Li-ion batteries is strongly associated with electrode microstructure change upon (de)lithiation. Now, an operando X-ray tomography approach is shown to correlate changes in the microstructure of electrodes to cell performance, and thereby predict degradation pathways.

  3. Battery cell module

    Energy Technology Data Exchange (ETDEWEB)

    Shambaugh, J.S.

    1981-11-23

    A modular lithium battery having a plurality of cells, having electrical connecting means connecting the cells to output terminals, and venting means for releasing discharge byproducts to a chemical scrubber is disclosed. Stainless steel cell casings are potted in an aluminum modular case with syntactic foam and epoxy. The wall thickness resulting is about 0.5 inches.

  4. Lightweight bipolar storage battery

    Science.gov (United States)

    Rowlette, John J. (Inventor)

    1992-01-01

    An apparatus [10] is disclosed for a lightweight bipolar battery of the end-plate cell stack design. Current flow through a bipolar cell stack [12] is collected by a pair of copper end-plates [16a,16b] and transferred edgewise out of the battery by a pair of lightweight, low resistance copper terminals [28a,28b]. The copper terminals parallel the surface of a corresponding copper end-plate [16a,16b] to maximize battery throughput. The bipolar cell stack [12], copper end-plates [16a,16b] and copper terminals [28a,28b] are rigidly sandwiched between a pair of nonconductive rigid end-plates [20] having a lightweight fiber honeycomb core which eliminates distortion of individual plates within the bipolar cell stack due to internal pressures. Insulating foam [30] is injected into the fiber honeycomb core to reduce heat transfer into and out of the bipolar cell stack and to maintain uniform cell performance. A sealed battery enclosure [ 22] exposes a pair of terminal ends [26a,26b] for connection with an external circuit.

  5. Pacemaker Syndrome. Case report. Síndrome de marcapaso. Presentación de un caso.

    Directory of Open Access Journals (Sweden)

    Brandy Viera Valdés

    2009-11-01

    Full Text Available Pacemaker Syndrome is a clinical entity, most frequently produced by an inadequate AV synchrony, in which the phenomenom of retrograde AV conduction plays a major role, generally in patients with a single-chamber pacemaker with a WI stimulation mode. Main symptoms are: syncope, severe blood hypotension and ­­­­­­­­­­­­­­­­­congestive heart failure. The treatment, both prophylactic and therapeutical, would be related to the appropriate choice of stimulation mode, starting from individual analysis of each patient. We present a case of a patient with pacemaker syndrome, whose primary symptom was syncope on small physical activity, which made him unable to perform ordinary activities. The solution to the problem was substitution of single-chamber stimulation mode by a dual-chamber DDDR system, new surgery and placing of a ­­­electrode being necessary.El síndrome de marcapaso es una entidad clínica, producida de forma más frecuente por una sincronización inadecuada de la contracción auricular y ventricular, en la que juega un papel importante el fenómeno de conducción retrograda, generalmente en pacientes con un marcapaso unicameral con un modo de estimulación VVI. Sus síntomas más importantes son: síncope, hipotensión arterial severa e insuficiencia cardiaca congestiva. El tratamiento, tanto profiláctico como terapéutico, estaría relacionado con la elección adecuada del modo de estimulación, a partir del análisis individualizado de cada paciente. Se presenta el caso de un paciente con síndrome de marcapaso, cuyo síntoma fundamental era el síncope ante pequeños esfuerzos, lo cual lo incapacitaba para realizar actividades ordinarias, la solución del problema fue la sustitución del modo de estimulación monocameral VVI por un sistema bicameral DDDR, fue necesario una nueva intervención quirúrgica y colocación de un cable electrodo auricular.

  6. Brain natriuretic peptide as a predictor of heart failure in patients with permanent pacemaker

    Directory of Open Access Journals (Sweden)

    Jelić Vera

    2007-01-01

    Full Text Available Introduction: Brain natriuretic peptide (BNP has a role in control of cardiovascular and renal functions. Objective The objective was to assess the predictive value of BNP levels for development of heart failure in patients with permanent pacemakers. Method In patients with implanted DDD pacemakers, BNP levels were measured at rest and after exercise testing, on DDD and VVI modes. There were 42 patients (25 males; 59.5%, without symptoms or signs of coronary disease or heart failure, and with normal echocardiograms. According to BNP levels, the patients were divided into three groups: with BNP levels lower than 80 pg/ml, BNP ranging from 81-150 pg/ml, and BNP levels over 151 pg/ml. Results In the first group (27 patients, BNP levels were significantly higher on VVI compared to DDD mode, both at rest and after exercise (p<0.01, with all BNP levels within normal range. In the second group (5 pts, BNP levels at rest were also significantly higher on VVI than on DDD mode, p<0.05. After exercise, these values were also higher on VVI compared to DDD mode, but without statistical significance. The third group (10 pts as a whole had higher BNP values on VVI compared to DDD mode, with no statistical significance. In patients from this group who later developed heart failure, BNP levels were found to be significantly lower on DDD as opposed to VVI mode at rest, p<0.05, and even higher significance was found after exercise, p<0.01. After 6-year follow-up, 2 out of 5 patients from the second group developed dilated cardiomyopathy, and 8/10 patients in the third group experienced heart failure with LV EF 34.1±10%, LV EDD 6.1±0.42 cm, LV ESD 4.8±0.45 cm. Five of these patients died within the follow-up period. Conclusion The increased BNP levels can be valuable for early screening of patients with higher risk of heart failure. In patients with increased BNP at the time of pacemaker implantation, DDD pacing is a modality of choice.

  7. Heart pacemaker

    Science.gov (United States)

    ... Mann DL, Zipes DP, Libby P, Bonow RO, Braunwald E, eds. Braunwald's Heart Disease: A Textbook of Cardiovascular Medicine . 10th ... Mann DL, Zipes DP, Libby P, Bonow RO, Braunwald E, eds. Braunwald's Heart Disease: A Textbook of ...

  8. [Psychosomatic aspects of cardiac arrhythmias].

    Science.gov (United States)

    Siepmann, Martin; Kirch, Wilhelm

    2010-07-01

    Emotional stress facilitates the occurrence of cardiac arrhythmias including sudden cardiac death. The prevalence of anxiety and depression is increased in cardiac patients as compared to the normal population. The risk of cardiovascular mortality is enhanced in patients suffering from depression. Comorbid anxiety disorders worsen the course of cardiac arrhythmias. Disturbance of neurocardiac regulation with predominance of the sympathetic tone is hypothesized to be causative for this. The emotional reaction to cardiac arrhythmias is differing to a large extent between individuals. Emotional stress may result from coping with treatment of cardiac arrhythmias. Emotional stress and cardiac arrhythmias may influence each other in the sense of a vicious circle. Somatoform cardiac arrhythmias are predominantly of psychogenic origin. Instrumental measures and frequent contacts between physicians and patients may facilitate disease chronification. The present review is dealing with the multifaceted relationships between cardiac arrhythmias and emotional stress. The underlying mechanisms and corresponding treatment modalities are discussed.

  9. RyR-NCX-SERCA local crosstalk ensures pacemaker cell function at rest and during the fight-or-flight reflex

    Science.gov (United States)

    Maltsev, Anna V.; Yaniv, Yael; Stern, Michael D.; Lakatta, Edward G.; Maltsev, Victor A.

    2015-01-01

    Rationale A recent study published in Circulation Research by Gao et al. employed SA node-targeted, incomplete Ncx1-knockout (KO) in mice to explore the role of the Na+/Ca2+ exchanger (NCX) in cardiac pacemaker. The authors concluded that NCX is required for increasing sinus rates, but not for maintaining resting heart rate. This conclusion was based, in part, on numerical model simulations performed by Gao et al. that reproduced their experimental results of unchanged action potentials in the KO SA node cells. The authors, however, did not simulate the NCX current (INCX), i.e. the subject of the study. Objective We extended numerical examinations to simulate INCX in their incomplete KO SA node cells that is crucial to interpret the study results. Methods and Results INCX and Ca2+ dynamics were simulated using different contemporary numerical models of SA node cells. We found that minimum diastolic Ca2+ levels and INCX amplitudes generated by remaining NCX molecules (only 20% of control) remained almost unchanged. Simulations using a new local Ca2+ control model indicate that these powerful compensatory mechanisms involve complex local cross-talk of Ca2+ cycling proteins and NCX. Specifically, lower NCX expression facilitates Ca2+-induced Ca2+ release and larger local Ca2+ releases that stabilize diastolic INCX. Further reduction of NCX expression results in arrhythmia and halt of automaticity. Conclusions Remaining NCX molecules in the incomplete KO model likely produce almost the same diastolic INCX as in wild-type cells. INCX contribution is crucially important for both basal automaticity of SA node cells and during the fight-or-flight reflex. PMID:24158576

  10. Tricuspid valve repair for torrential tricuspid regurgitation after permanent pacemaker lead extraction.

    Science.gov (United States)

    Mehrotra, Deepak; Kejriwal, Nand K

    2011-01-01

    Tricuspid regurgitation secondary to percutaneous lead extraction is uncommon, and it rarely requires surgical intervention. Most tricuspid regurgitation occurs during the implantation of tined leads, which can be entrapped in the tricuspid valve apparatus and may require immediate withdrawal. Severe tricuspid regurgitation as a sequela of extracting chronically implanted leads has rarely been reported. Herein, we report a case of torrential tricuspid regurgitation in a 67-year-old woman after the extraction of a permanent pacemaker lead. The regurgitation was confirmed on transesophageal echocardiography during lead extraction, and the tricuspid valve was successfully repaired with suture bicuspidization of the valve and the support of ring annuloplasty. A short review of the relevant literature follows the case report.

  11. [Blood supply as a factor regulating pacemaker activity of the rat uterine horn].

    Science.gov (United States)

    Kazarian, K V; Unanian, N G; Melkonian, N N

    2013-01-01

    Effect of ischemia of the uterine artery supplying with blood the main rhythmogenic zone (the ovarian region) of the uterine horn on parameters of activity both of this locus and of all subsequent pacemaker areas up to the uterine cervix was studied in non-pregnant rats. The most pronounced changes in characteristics of the activity (amplitude, frequency, and burst genesis duration) were revealed in the ovarian horn end. The uterine corpus and the horn cervical end were less affected by ischemia. Meanwhile, under these conditions, amplitude of the slow-wave oscillations rose more than 1.5 times. The obtained data allow us to conclude about the presence of a certain connection between the horn ovarian end and the uterine cervix. Morphological studies have revealed strong vascularization of the upper part of uterine horn.

  12. Reevaluation of the indications for permanent pacemaker implantation after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Bjerre Thygesen, Julie; Loh, Poay Huan; Cholteesupachai, Jiranut;

    2014-01-01

    AIMS: Conduction abnormalities (CA) requiring permanent pacemaker (PPM) are a well-known complication after transcatheter aortic valve implantation (TAVI). This study aimed to determine the incidence of TAVI-related PPM and reevaluate the indications for PPM after the periprocedural period. METHODS...... AND RESULTS: A total of 258 consecutive patients underwent TAVI with the Medtronic CoreValve (MCV), whereas 24 patients were excluded from the study. TAVI-related PPM was defined as PPM implantation ≤30 days after the procedure and due to atrioventricular block (AVB). Third-degree AVB, second-degree type......-II, or advanced second-degree AVB were considered as absolute indications for PPM. The incidence of TAVI-related PPM implantation was 27.4%. Forty-six patients (19.7%) had an absolute indication for PPM, but CA had resolved in 50% beyond the periprocedural period. Electrocardiographic analysis of the patients who...

  13. Circadian rhythms in healthy aging--effects downstream from the pacemaker

    Science.gov (United States)

    Monk, T. H.; Kupfer, D. J.

    2000-01-01

    Using both previously published findings and entirely new data, we present evidence in support of the argument that the circadian dysfunction of advancing age in the healthy human is primarily one of failing to transduce the circadian signal from the circadian timing system (CTS) to rhythms "downstream" from the pacemaker rather than one of failing to generate the circadian signal itself. Two downstream rhythms are considered: subjective alertness and objective performance. For subjective alertness, we show that in both normal nychthemeral (24 h routine, sleeping at night) and unmasking (36 h of constant wakeful bed rest) conditions, advancing age, especially in men, leads to flattening of subjective alertness rhythms, even when circadian temperature rhythms are relatively robust. For objective performance, an unmasking experiment involving manual dexterity, visual search, and visual vigilance tasks was used to demonstrate that the relationship between temperature and performance is strong in the young, but not in older subjects (and especially not in older men).

  14. Electrical Injury-Induced Complete Atrioventricular Block: Is Permanent Pacemaker Required?

    Directory of Open Access Journals (Sweden)

    Osman Beton

    2015-01-01

    Full Text Available A considerable percentage of electrical injuries occur as a result of work activities. Electrical injury can lead to various cardiovascular disorders: acute myocardial necrosis, myocardial ischemia, heart failure, arrhythmias, hemorrhagic pericarditis, acute hypertension with peripheral vasospasm, and anomalous, nonspecific ECG alterations. Ventricular fibrillation is the most common arrhythmia resulting from electrical injury and is the leading cause of death in electrical (especially low voltage alternating current injury cases. Asystole, premature ventricular contractions, ventricular tachycardia, conduction disorders (various degrees of heart blocks, bundle-brunch blocks, supraventricular tachycardia, and atrial fibrillation are the other arrhythmic complications of electrical injury. Complete atrioventricular block has rarely been reported and permanent pacemaker was required for the treatment in some of these cases. Herein, we present a case of reversible complete atrioventricular block due to low voltage electrical injury in a young electrical technician.

  15. Life testing of implantable batteries for a total artificial heart.

    Science.gov (United States)

    Powers, R A; Wolga, A E; Ochs, B D; Yu, L S; Kung, R T

    1993-01-01

    Although lithium cells may promise to be ideal as a rechargeable internal battery for a TAH, NiCd cells remain the most easily accessible off the shelf energy source. Twelve 1.2 A.hr prismatic NiCd (Sanyo, San Diego, CA) cells in series are being tested under the load condition of our TAH. The load consisted of a 1.5 A DC current with 1 A pulses of 40 msec duration at 3.33 Hz (100 bpm), a condition that can generate up to 8 L/min of cardiac output at physiologic pressures. Cells were tested at 37 degrees C. Cell voltages and temperatures were monitored. Testing was accelerated to five charge/discharge cycles per day. Discharge was terminated when any one cell dropped below 1.1 V. Charging (C/4) was continued until the battery voltage indicated a change in slope. Cell temperatures remained below 42 degrees C throughout the charge/discharge cycle. The battery pack settled to a nearly constant capacity of over 25 min after 10 cycles and has accumulated more than 1,000 cycles. Voltage differences among cells were small (SD mV), indicating consistency among cells. NiCd cells can serve as a reliable interim for TAH internal battery application.

  16. Modular Battery Charge Controller

    Science.gov (United States)

    Button, Robert; Gonzalez, Marcelo

    2009-01-01

    A new approach to masterless, distributed, digital-charge control for batteries requiring charge control has been developed and implemented. This approach is required in battery chemistries that need cell-level charge control for safety and is characterized by the use of one controller per cell, resulting in redundant sensors for critical components, such as voltage, temperature, and current. The charge controllers in a given battery interact in a masterless fashion for the purpose of cell balancing, charge control, and state-of-charge estimation. This makes the battery system invariably fault-tolerant. The solution to the single-fault failure, due to the use of a single charge controller (CC), was solved by implementing one CC per cell and linking them via an isolated communication bus [e.g., controller area network (CAN)] in a masterless fashion so that the failure of one or more CCs will not impact the remaining functional CCs. Each micro-controller-based CC digitizes the cell voltage (V(sub cell)), two cell temperatures, and the voltage across the switch (V); the latter variable is used in conjunction with V(sub cell) to estimate the bypass current for a given bypass resistor. Furthermore, CC1 digitizes the battery current (I1) and battery voltage (V(sub batt) and CC5 digitizes a second battery current (I2). As a result, redundant readings are taken for temperature, battery current, and battery voltage through the summation of the individual cell voltages given that each CC knows the voltage of the other cells. For the purpose of cell balancing, each CC periodically and independently transmits its cell voltage and stores the received cell voltage of the other cells in an array. The position in the array depends on the identifier (ID) of the transmitting CC. After eight cell voltage receptions, the array is checked to see if one or more cells did not transmit. If one or more transmissions are missing, the missing cell(s) is (are) eliminated from cell

  17. Cardiac radiology: centenary review.

    Science.gov (United States)

    de Roos, Albert; Higgins, Charles B

    2014-11-01

    During the past century, cardiac imaging technologies have revolutionized the diagnosis and treatment of acquired and congenital heart disease. Many important contributions to the field of cardiac imaging were initially reported in Radiology. The field developed from the early stages of cardiac imaging, including the use of coronary x-ray angiography and roentgen kymography, to nowadays the widely used echocardiographic, nuclear medicine, cardiac computed tomographic (CT), and magnetic resonance (MR) applications. It is surprising how many of these techniques were not recognized for their potential during their early inception. Some techniques were described in the literature but required many years to enter the clinical arena and presently continue to expand in terms of clinical application. The application of various CT and MR contrast agents for the diagnosis of myocardial ischemia is a case in point, as the utility of contrast agents continues to expand the noninvasive characterization of myocardium. The history of cardiac imaging has included a continuous process of advances in our understanding of the anatomy and physiology of the cardiovascular system, along with advances in imaging technology that continue to the present day.

  18. Persistent sodium current drives conditional pacemaking in CA1 pyramidal neurons under muscarinic stimulation.

    Science.gov (United States)

    Yamada-Hanff, Jason; Bean, Bruce P

    2013-09-18

    Hippocampal CA1 pyramidal neurons are normally quiescent but can fire spontaneously when stimulated by muscarinic agonists. In brain slice recordings from mouse CA1 pyramidal neurons, we examined the ionic basis of this activity using interleaved current-clamp and voltage-clamp experiments. Both in control and after muscarinic stimulation, the steady-state current-voltage curve was dominated by inward TTX-sensitive persistent sodium current (I(NaP)) that activated near -75 mV and increased steeply with depolarization. In control, total membrane current was net outward (hyperpolarizing) near -70 mV so that cells had a stable resting potential. Muscarinic stimulation activated a small nonselective cation current so that total membrane current near -70 mV shifted to become barely net inward (depolarizing). The small depolarization triggers regenerative activation of I(NaP), which then depolarizes the cell from -70 mV to spike threshold. We quantified the relative contributions of I(NaP), hyperpolarization-activated cation current (I(h)), and calcium current to pacemaking by using the cell's own firing as a voltage command along with specific blockers. TTX-sensitive sodium current was substantial throughout the entire interspike interval, increasing as the membrane potential approached threshold, while both Ih and calcium current were minimal. Thus, spontaneous activity is driven primarily by activation of I(NaP) in a positive feedback loop starting near -70 mV and providing increasing inward current to threshold. These results show that the pacemaking "engine" from I(NaP) is an inherent property of CA1 pyramidal neurons that can be engaged or disengaged by small shifts in net membrane current near -70 mV, as by muscarinic stimulation.

  19. One-Year Follow-Up of Patients Undergoing Transvenous Extraction of Pacemaker and Defibrillator Leads.

    Directory of Open Access Journals (Sweden)

    Maciej Kempa

    Full Text Available The number of pacemaker and ICD implantations has increased substantially in the recent years. Therefore, complications are also observed in a greater number. In many cases, transvenous extraction of the previously implanted device (pacemaker or ICD is the only solution. One may find in the literature information about the efficacy and safety of that procedure, but data concerning the results of long-term follow up are still limited.The aim of the study was to assess the one-year mortality in the cohort of patients undergoing transvenous lead extraction procedures in our centre.Records of the patients undergoing transvenous lead removal in the Department of Cardiology and Electrotherapy of the Medical University of Gdańsk were analyzed. We collected detailed information about 192 patients that had undergone the procedure from January 2003 until June 2012. Data were collected from medical and surgical records. We analyzed concomitant diseases, indications, and possible complications. Long-term follow-up data were gathered in the follow-up ambulatory records and over-the-phone interviews with patients or families. In several cases, we consulted the database of the Polish National Health Fund.During the early post-operative period 5 patients died, although none of those deaths was associated with the procedure itself. No other major complications were observed. During one-year follow-up other 5 patients died, which gave the overall one-year survival rate of 92.7%. Heart failure, renal failure and an infective indication showed significant association with increased mortality.Results of transvenous lead extraction, a relatively safe procedure, should be assessed over time extending beyond the sole perioperative period. Some complications may be delayed in their nature, and may be observed only during the long-term follow up.

  20. Advanced Battery Manufacturing (VA)

    Energy Technology Data Exchange (ETDEWEB)

    Stratton, Jeremy

    2012-09-30

    LiFeBATT has concentrated its recent testing and evaluation on the safety of its batteries. There appears to be a good margin of safety with respect to overheating of the cells and the cases being utilized for the batteries are specifically designed to dissipate any heat built up during charging. This aspect of LiFeBATT’s products will be even more fully investigated, and assuming ongoing positive results, it will become a major component of marketing efforts for the batteries. LiFeBATT has continued to receive prismatic 20 Amp hour cells from Taiwan. Further testing continues to indicate significant advantages over the previously available 15 Ah cells. Battery packs are being assembled with battery management systems in the Danville facility. Comprehensive tests are underway at Sandia National Laboratory to provide further documentation of the advantages of these 20 Ah cells. The company is pursuing its work with Hybrid Vehicles of Danville to critically evaluate the 20 Ah cells in a hybrid, armored vehicle being developed for military and security applications. Results have been even more encouraging than they were initially. LiFeBATT is expanding its work with several OEM customers to build a worldwide distribution network. These customers include a major automotive consulting group in the U.K., an Australian maker of luxury off-road campers, and a number of makers of E-bikes and scooters. LiFeBATT continues to explore the possibility of working with nations that are woefully short of infrastructure. Negotiations are underway with Siemens to jointly develop a system for using photovoltaic generation and battery storage to supply electricity to communities that are not currently served adequately. The IDA has continued to monitor the progress of LiFeBATT’s work to ensure that all funds are being expended wisely and that matching funds will be generated as promised. The company has also remained current on all obligations for repayment of an IDA loan and lease

  1. 49 CFR 173.159 - Batteries, wet.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Batteries, wet. 173.159 Section 173.159... Batteries, wet. (a) Electric storage batteries, containing electrolyte acid or alkaline corrosive battery fluid (wet batteries), may not be packed with other materials except as provided in paragraphs (g)...

  2. Pediatric cardiac postoperative care

    Directory of Open Access Journals (Sweden)

    Auler Jr. José Otávio Costa

    2002-01-01

    Full Text Available The Heart Institute of the University of São Paulo, Medical School is a referral center for the treatment of congenital heart diseases of neonates and infants. In the recent years, the excellent surgical results obtained in our institution may be in part due to modern anesthetic care and to postoperative care based on well-structured protocols. The purpose of this article is to review unique aspects of neonate cardiovascular physiology, the impact of extracorporeal circulation on postoperative evolution, and the prescription for pharmacological support of acute cardiac dysfunction based on our cardiac unit protocols. The main causes of low cardiac output after surgical correction of heart congenital disease are reviewed, and methods of treatment and support are proposed as derived from the relevant literature and our protocols.

  3. Comprehensive cardiac rehabilitation

    DEFF Research Database (Denmark)

    Kruse, Marie; Hochstrasser, Stefan; Zwisler, Ann-Dorthe O;

    2006-01-01

    OBJECTIVES: The costs of comprehensive cardiac rehabilitation are established and compared to the corresponding costs of usual care. The effect on health-related quality of life is analyzed. METHODS: An unprecedented and very detailed cost assessment was carried out, as no guidelines existed...... for the situation at hand. Due to challenging circumstances, the cost assessment turned out to be ex-post and top-down. RESULTS: Cost per treatment sequence is estimated to be approximately euro 976, whereas the incremental cost (compared with usual care) is approximately euro 682. The cost estimate is uncertain...... and may be as high as euro 1.877. CONCLUSIONS: Comprehensive cardiac rehabilitation is more costly than usual care, and the higher costs are not outweighed by a quality of life gain. Comprehensive cardiac rehabilitation is, therefore, not cost-effective....

  4. Toothache of cardiac origin.

    Science.gov (United States)

    Kreiner, M; Okeson, J P

    1999-01-01

    Pain referred to the orofacial structures can sometimes be a diagnostic challenge for the clinician. In some instances, a patient may complain of tooth pain that is completely unrelated to any dental source. This poses a diagnostic and therapeutic problem for the dentist. Cardiac pain most commonly radiates to the left arm, shoulder, neck, and face. In rare instances, angina pectoris may present as dental pain. When this occurs, an improper diagnosis frequently leads to unnecessary dental treatment or, more significantly, a delay of proper treatment. This delay may result in the patient experiencing an acute myocardial infarction. It is the dentist's responsibility to establish a proper diagnosis so that the treatment will be directed toward the source of pain and not to the site of pain. This article reviews the literature concerning referred pain of cardiac origin and presents a case report of toothache of cardiac origin.

  5. Infection after pacemaker implantation: infection rates and risk factors associated with infection in a population-based cohort study of 46299 consecutive patients

    DEFF Research Database (Denmark)

    Johansen, Jens Brock; Jørgensen, Ole Dan; Møller, Mogens

    2011-01-01

    Infection is a serious complication of pacemaker (PM) systems. Although the rate of infection has been debated, the figures are largely unknown. We therefore studied the incidence of PM infection and its associated risk factors in the Danish population....

  6. The cardiac anxiety questionnaire: cross-validation among cardiac inpatients

    NARCIS (Netherlands)

    Beek, M.H. van; Oude Voshaar, R.C.; Deelen, F.M. van; Balkom, A.J. van; Pop, G.A.; Speckens, A.E.

    2012-01-01

    OBJECTIVE: General anxiety symptoms are common in patients with cardiac disease and considered to have an adverse effect on cardiac prognosis. The role of specific cardiac anxiety, however, is still unknown. The aim of this study is to examine the factor structure, reliability, and validity of the D

  7. THE CARDIAC ANXIETY QUESTIONNAIRE : CROSS-VALIDATION AMONG CARDIAC INPATIENTS

    NARCIS (Netherlands)

    van Beek, M. H. C. T.; Voshaar, R. C. Oude; van Deelen, F. M.; van Balkom, A. J. L. M.; Pop, G.; Speckens, A. E. M.

    2012-01-01

    Objective: General anxiety symptoms are common in patients with cardiac disease and considered to have an adverse effect on cardiac prognosis. The role of specific cardiac anxiety, however, is still unknown. The aim of this study is to examine the factor structure, reliability, and validity of the D

  8. Electric batteries and the environment. Die Batterie und die Umwelt

    Energy Technology Data Exchange (ETDEWEB)

    Hiller, F.; Hartinger, L.; Kiehne, H.A.; Niklas, H.; Schiele, R.; Steil, H.U.

    1987-01-01

    The book deals with the production, use and waste management of batteries (accumulators and primary batteries), with regard to protection of the environment. Legal, technical and medical aspects are shown. There are numerous electro-chemical systems, but only few proved to be really good in practice. Most batteries contain lead, cadmium or mercury and must therefore be eliminated in a way doing no harm to the environment. Large quantities of the above named heavy metals are today already being recovered by means of appropriate procedures. The reduction of these heavy metals in batteries is also described to be a contribution to the protection of the environment. (orig.) With 67 figs.

  9. Smart battery controller for lithium sulfur dioxide batteries

    Science.gov (United States)

    Atwater, Terrill; Bard, Arnold; Testa, Bruce; Shader, William

    1992-08-01

    Each year, the U.S. Army purchases millions of lithium sulfur dioxide batteries for use in portable electronics equipment. Because of their superior rate capability and service life over a wide variety of conditions, lithium batteries are the power source of choice for military equipment. There is no convenient method of determining the available energy remaining in partially used lithium batteries; hence, users do not take full advantage of all the available battery energy. Currently, users replace batteries before each mission, which leads to premature disposal, and results in the waste of millions of dollars in battery energy every year. Another problem of the lithium battery is that it is necessary to ensure complete discharge of the cells when the useful life of the battery has been expended, or when a hazardous condition exists; a hazardous condition may result in one or more of the cells venting. The Electronics Technology and Devices Laboratory has developed a working prototype of a smart battery controller (SBC) that addresses these problems.

  10. Battery separator manufacturing process

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, N.I.; Sugarman, N.

    1974-12-27

    A battery with a positive plate, a negative plate, and a separator of polymeric resin having a degree of undesirable hydrophobia, solid below 180/sup 0/F, extrudable as a hot melt, and resistant to degradation by at least either acids or alkalies positioned between the plates is described. The separator comprises a nonwoven mat of fibers, the fibers being comprised of the polymeric resin and a wetting agent in an amount of 0.5 to 20 percent by weight based on the weight of the resin with the amount being incompatible with the resin below the melting point of the resin such that the wetting agent will bloom over a period of time at ambient temperatures in a battery, yet being compatible with the resin at the extrusion temperature and bringing about blooming to the surface of the fibers when the fibers are subjected to heat and pressure.

  11. The nuclear battery

    Science.gov (United States)

    Kozier, K. S.; Rosinger, H. E.

    The evolution and present status of an Atomic Energy of Canada Limited program to develop a small, solid-state, passively cooled reactor power supply known as the Nuclear Battery is reviewed. Key technical features of the Nuclear Battery reactor core include a heat-pipe primary heat transport system, graphite neutron moderator, low-enriched uranium TRISO coated-particle fuel and the use of burnable poisons for long-term reactivity control. An external secondary heat transport system extracts useful heat energy, which may be converted into electricity in an organic Rankine cycle engine or used to produce high-pressure steam. The present reference design is capable of producing about 2400 kW(t) (about 600 kW(e) net) for 15 full-power years. Technical and safety features are described along with recent progress in component hardware development programs and market assessment work.

  12. Block copolymer battery separator

    Science.gov (United States)

    Wong, David; Balsara, Nitash Pervez

    2016-04-26

    The invention herein described is the use of a block copolymer/homopolymer blend for creating nanoporous materials for transport applications. Specifically, this is demonstrated by using the block copolymer poly(styrene-block-ethylene-block-styrene) (SES) and blending it with homopolymer polystyrene (PS). After blending the polymers, a film is cast, and the film is submerged in tetrahydrofuran, which removes the PS. This creates a nanoporous polymer film, whereby the holes are lined with PS. Control of morphology of the system is achieved by manipulating the amount of PS added and the relative size of the PS added. The porous nature of these films was demonstrated by measuring the ionic conductivity in a traditional battery electrolyte, 1M LiPF.sub.6 in EC/DEC (1:1 v/v) using AC impedance spectroscopy and comparing these results to commercially available battery separators.

  13. Battery charging stations

    Energy Technology Data Exchange (ETDEWEB)

    Bergey, M.

    1997-12-01

    This paper discusses the concept of battery charging stations (BCSs), designed to service rural owners of battery power sources. Many such power sources now are transported to urban areas for recharging. A BCS provides the opportunity to locate these facilities closer to the user, is often powered by renewable sources, or hybrid systems, takes advantage of economies of scale, and has the potential to provide lower cost of service, better service, and better cost recovery than other rural electrification programs. Typical systems discussed can service 200 to 1200 people, and consist of stations powered by photovoltaics, wind/PV, wind/diesel, or diesel only. Examples of installed systems are presented, followed by cost figures, economic analysis, and typical system design and performance numbers.

  14. Navy Lithium Battery Safety

    Science.gov (United States)

    2010-07-14

    lithium -sulfur dioxide (Li-SO2), lithium - thionyl chloride (Li- SOCL2), and lithium -sulfuryl chloride (Li-S02CL2...and 1980’s with active primary cells: Lithium -sulfur dioxide (Li-SO2) Lithium - thionyl chloride (Li-SOCL2) Lithium -sulfuryl chloride (Li-S0 CL ) 2 2...DISTRIBUTION A. Approved for public release; distribution unlimited. NAVY LITHIUM BATTERY SAFETY John Dow1 and Chris Batchelor2 Naval

  15. Miniaturized nuclear battery

    Energy Technology Data Exchange (ETDEWEB)

    Adler, K.; Ducommun, G.

    1976-01-20

    The invention relates to a miniaturized nuclear battery, consisting of several in series connected cells, wherein each cell contains a support which acts as positive pole and which supports on one side a ..beta..-emitter, above said emitter is a radiation resisting insulation layer which is covered by an absorption layer, above which is a collector layer, and wherein the in series connected calls are disposed in an airtight case.

  16. Interventricular cardiac resynchronization with right ventricular apical pacing in a patient with Ebstein's defect.

    Science.gov (United States)

    Maffe, Stefano; Perucca, Antonello; Paffoni, Paola; Signorotti, Fabiana; Pardo, Nicolò Franchetti; Dellavesa, Pierfranco; Parravicini, Umberto; Zenone, Franco; Paino, Anna Maria; Bielli, Massimo; Carola, Federico; Zanetta, Marco

    2008-06-01

    We present the case of a patient with Ebstein's defect surgically corrected, and a complete right bundle branch block (RBBB) documented on echocardiogram. After an episode of near syncope due to a high-grade atrioventricular (AV) block, the patient was assisted with a bicameral DDDR pacemaker implanted with traditional right ventricular apical pacing. After the DDDR, and after stimulation with an AV delay of 180 ms, a narrow QRS complex was observed. Meanwhile, the typical left bundle branch block morphology of the right ventricular pacing and the native RBBB morphology were missing. The QRS complex narrowing persisted, even with physical activity and also with the heart rate progression. An echocardiographic study confirmed an improvement of the cardiac resynchronization parameters with this programmed stimulation.

  17. Same-Single-Cell Analysis of Pacemaker-Specific Markers in Human Induced Pluripotent Stem Cell-Derived Cardiomyocyte Subtypes Classified by Electrophysiology.

    Science.gov (United States)

    Yechikov, Sergey; Copaciu, Raul; Gluck, Jessica M; Deng, Wenbin; Chiamvimonvat, Nipavan; Chan, James W; Lieu, Deborah K

    2016-07-19

    Insights into the expression of pacemaker-specific markers in human induced pluripotent stem cell (hiPSC)-derived cardiomyocyte subtypes can facilitate the enrichment and track differentiation and maturation of hiPSC-derived pacemaker-like cardiomyocytes. To date, no study has directly assessed gene expression in each pacemaker-, atria-, and ventricular-like cardiomyocyte subtype derived from hiPSCs since currently the subtypes of these immature cardiomyocytes can only be identified by action potential profiles. Traditional acquisition of action potentials using patch-clamp recordings renders the cells unviable for subsequent analysis. We circumvented these issues by acquiring the action potential profile of a single cell optically followed by assessment of protein expression through immunostaining in that same cell. Our same-single-cell analysis for the first time revealed expression of proposed pacemaker-specific markers-hyperpolarization-activated cyclic nucleotide-modulated (HCN)4 channel and Islet (Isl)1-at the protein level in all three hiPSC-derived cardiomyocyte subtypes. HCN4 expression was found to be higher in pacemaker-like hiPSC-derived cardiomyocytes than atrial- and ventricular-like subtypes but its downregulation over time in all subtypes diminished the differences. Isl1 expression in pacemaker-like hiPSC-derived cardiomyocytes was initially not statistically different than the contractile subtypes but did become statistically higher than ventricular-like cells with time. Our observations suggest that although HCN4 and Isl1 are differentially expressed in hiPSC-derived pacemaker-like relative to ventricular-like cardiomyocytes, these markers alone are insufficient in identifying hiPSC-derived pacemaker-like cardiomyocytes. Stem Cells 2016.

  18. Perioperative management of cardiac disease.

    Science.gov (United States)

    Aresti, N A; Malik, A A; Ihsan, K M; Aftab, S M E; Khan, W S

    2014-01-01

    Pre-existing cardiac disease contributes significantly to morbidity and mortality amongst patients undergoing non cardiac surgery. Patients with pre-existing cardiac disease or with risk factors for it, have as much as a 3.9% risk of suffering a major perioperative cardiac event (Lee et al 1999, Devereaux 2005). Furthermore, the incidence of perioperative myocardial infarction (MI) is increased 10 to 50 fold in patients with previous coronary events (Jassal 2008).

  19. High energy density lithium batteries

    CERN Document Server

    Aifantis, Katerina E; Kumar, R Vasant

    2010-01-01

    Cell phones, portable computers and other electronic devices crucially depend on reliable, compact yet powerful batteries. Therefore, intensive research is devoted to improving performance and reducing failure rates. Rechargeable lithium-ion batteries promise significant advancement and high application potential for hybrid vehicles, biomedical devices, and everyday appliances. This monograph provides special focus on the methods and approaches for enhancing the performance of next-generation batteries through the use of nanotechnology. Deeper understanding of the mechanisms and strategies is

  20. Membranes in Lithium Ion Batteries

    Directory of Open Access Journals (Sweden)

    Junbo Hou

    2012-07-01

    Full Text Available Lithium ion batteries have proven themselves the main choice of power sources for portable electronics. Besides consumer electronics, lithium ion batteries are also growing in popularity for military, electric vehicle, and aerospace applications. The present review attempts to summarize the knowledge about some selected membranes in lithium ion batteries. Based on the type of electrolyte used, literature concerning ceramic-glass and polymer solid ion conductors, microporous filter type separators and polymer gel based membranes is reviewed.

  1. Membranes in lithium ion batteries.

    Science.gov (United States)

    Yang, Min; Hou, Junbo

    2012-07-04

    Lithium ion batteries have proven themselves the main choice of power sources for portable electronics. Besides consumer electronics, lithium ion batteries are also growing in popularity for military, electric vehicle, and aerospace applications. The present review attempts to summarize the knowledge about some selected membranes in lithium ion batteries. Based on the type of electrolyte used, literature concerning ceramic-glass and polymer solid ion conductors, microporous filter type separators and polymer gel based membranes is reviewed.

  2. Air and metal hydride battery

    Energy Technology Data Exchange (ETDEWEB)

    Lampinen, M.; Noponen, T. [Helsinki Univ. of Technology, Otaniemi (Finland). Lab. of Applied Thermodynamics

    1998-12-31

    The main goal of the air and metal hydride battery project was to enhance the performance and manufacturing technology of both electrodes to such a degree that an air-metal hydride battery could become a commercially and technically competitive power source for electric vehicles. By the end of the project it was possible to demonstrate the very first prototype of the air-metal hydride battery at EV scale, achieving all the required design parameters. (orig.)

  3. Data analysis in cardiac arrhythmias.

    Science.gov (United States)

    Rodrigo, Miguel; Pedrón-Torecilla, Jorge; Hernández, Ismael; Liberos, Alejandro; Climent, Andreu M; Guillem, María S

    2015-01-01

    Cardiac arrhythmias are an increasingly present in developed countries and represent a major health and economic burden. The occurrence of cardiac arrhythmias is closely linked to the electrical function of the heart. Consequently, the analysis of the electrical signal generated by the heart tissue, either recorded invasively or noninvasively, provides valuable information for the study of cardiac arrhythmias. In this chapter, novel cardiac signal analysis techniques that allow the study and diagnosis of cardiac arrhythmias are described, with emphasis on cardiac mapping which allows for spatiotemporal analysis of cardiac signals.Cardiac mapping can serve as a diagnostic tool by recording cardiac signals either in close contact to the heart tissue or noninvasively from the body surface, and allows the identification of cardiac sites responsible of the development or maintenance of arrhythmias. Cardiac mapping can also be used for research in cardiac arrhythmias in order to understand their mechanisms. For this purpose, both synthetic signals generated by computer simulations and animal experimental models allow for more controlled physiological conditions and complete access to the organ.

  4. Biosynthesis of cardiac natriuretic peptides

    DEFF Research Database (Denmark)

    Goetze, Jens Peter

    2010-01-01

    Cardiac-derived peptide hormones were identified more than 25 years ago. An astonishing amount of clinical studies have established cardiac natriuretic peptides and their molecular precursors as useful markers of heart disease. In contrast to the clinical applications, the biogenesis of cardiac...

  5. Cardiac troponins and high-sensitivity cardiac troponin assays.

    Science.gov (United States)

    Conrad, Michael J; Jarolim, Petr

    2014-03-01

    Measurement of circulating cardiac troponins I and T has become integral to the diagnosis of myocardial infarction. This article discusses the structure and function of the troponin complex and the release of cardiac troponin molecules from the injured cardiomyocyte into the circulation. An overview of current cardiac troponin assays and their classification according to sensitivity is presented. The diagnostic criteria, role, and usefulness of cardiac troponin for myocardial infarction are discussed. In addition, several examples are given of the usefulness of high-sensitivity cardiac troponin assays for short-term and long-term prediction of adverse events.

  6. Study on quality of life after implantation of pacemaker in aged patients%老年患者心脏起搏器植入术后生活质量的随访研究

    Institute of Scientific and Technical Information of China (English)

    梁锦军; 杨波; 伍晟; 黄鹤; 陈芳; 郭柱力

    2011-01-01

    Objective: To evaluate quality of life after implantation of pacemaker in aged patients. Methods: A total of 93 aged patients were selected, aged 75~ 84 [average age (78. 54 + 3. 05) ] years, including 20 cases (21. 5%) of atri-oventricular block (AVB) with normal sinus node function, 45 cases (48. 4% ) of sick sinus syndrome (SSS) , 24 cases (25. 8%) of atrial fibrillation (AF) and 4 cases (4. 3%) of other heart diseases. According to the score rules of quality of life instrument for patients with pacemaker, scores of quality of life were calculated before and one year after pacemaker implantation, lower scores indicated a better quality of life. Results: Compared with before treatment, total scores of quality of life of the patients significantly decreased [ (89. 95 + 2. 53) scores vs. (86. 12il. 61) scores, P< 0. 01], scores of physical function, social function, psychologic function and general recognition improved significantly, and improvement of physical function was most significant [ (31. 45±2. 41) scores vs. (28. 63±1. 45) scores, P< 0. 01]. The factors that affected quality of life in aged patients included gender, possession of spouse, classification of cardiac function, P<0. 05 all. Conclusion: Implantation of pacemaker could significantly improve quality of life in aged patients.%目的:评价老年患者心脏起搏器植入后的生活质量.方法:入选老年患者93例,年龄75~84,平均(78.54±3.05)岁,房室传导阻滞(AVB)且窦房结功能正常患者20例(21.5%),病态窦房结综合征(SSS)患者45例(48.4%),房颤(AF)患者24例(25.8%),其他疾患4例(4.3%).按照起搏器生活质量测定量表计分规则,于介入治疗前和治疗一年后计算生活质量得分,分值越低说明生活质量状况越好.结果:与治疗前比较,起搏器植入术后一年患者生活质量总评分明显降低 [(89.95±2.53)分∶(86.12±1.61)分,P<0.01],躯体功能、社会功能、心理功能以及一般认识均得到了

  7. Battery Post-Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Post-test diagnostics of aged batteries can provide additional information regarding the cause of performance degradation, which, previously, could be only inferred...

  8. A VRLA battery simulation model

    Energy Technology Data Exchange (ETDEWEB)

    Pascoe, P.E.; Anbuky, A.H. [Invensys Energy Systems NZ Limited, Christchurch (New Zealand)

    2004-05-01

    A valve regulated lead acid (VRLA) battery simulation model is an invaluable tool for the standby power system engineer. The obvious use for such a model is to allow the assessment of battery performance. This may involve determining the influence of cells suffering from state of health (SOH) degradation on the performance of the entire string, or the running of test scenarios to ascertain the most suitable battery size for the application. In addition, it enables the engineer to assess the performance of the overall power system. This includes, for example, running test scenarios to determine the benefits of various load shedding schemes. It also allows the assessment of other power system components, either for determining their requirements and/or vulnerabilities. Finally, a VRLA battery simulation model is vital as a stand alone tool for educational purposes. Despite the fundamentals of the VRLA battery having been established for over 100 years, its operating behaviour is often poorly understood. An accurate simulation model enables the engineer to gain a better understanding of VRLA battery behaviour. A system level multipurpose VRLA battery simulation model is presented. It allows an arbitrary battery (capacity, SOH, number of cells and number of strings) to be simulated under arbitrary operating conditions (discharge rate, ambient temperature, end voltage, charge rate and initial state of charge). The model accurately reflects the VRLA battery discharge and recharge behaviour. This includes the complex start of discharge region known as the coup de fouet. (author)

  9. Characterization of vanadium flow battery

    Energy Technology Data Exchange (ETDEWEB)

    Bindner, H.; Ekman, C.; Gehrke, O.; Isleifsson, F.

    2010-10-15

    This report summarizes the work done at Risoe DTU testing a vanadium flow battery as part of the project 'Characterisation of Vanadium Batteries' (ForskEl project 6555) with the partners PA Energy A/S and OI Electric A/S under the Danish PSO energy research program. A 15kW/120kWh vanadium battery has been installed as part of the distributed energy systems experimental facility, SYSLAB, at Risoe DTU. A test programme has been carried out to get hands-on experience with the technology, to characterize the battery from a power system point of view and to assess it with respect to integration of wind energy in the Danish power system. The battery has been in operation for 18 months. During time of operation the battery has not shown signs of degradation of performance. It has a round-trip efficiency at full load of approximately 60% (depending on temperature and SOC). The sources of the losses are power conversion in cell stacks/electrolyte, power converter, and auxiliary power consumption from pumps and controller. The response time for the battery is limited at 20kW/s by the ramp rate of the power converter. The battery can thus provide power and frequency support for the power system. Vanadium battery is a potential technology for storage based services to the power system provided investment and O and M cost are low enough and long term operation is documented. (Author)

  10. Usefulness of Hemodynamic Sensors for Physiologic Cardiac Pacing in Heart Failure Patients

    Directory of Open Access Journals (Sweden)

    Eraldo Occhetta

    2011-01-01

    Full Text Available The rate adaptive sensors applied to cardiac pacing should respond as promptly as the normal sinus node with an highly specific and sensitive detection of the need of increasing heart rate. Sensors operating alone may not provide optimal heart responsiveness: central venous pH sensing, variations in the oxygen content of mixed venous blood, QT interval, breathing rate and pulmonary minute ventilation monitored by thoracic impedance variations, activity sensors. Using sensors that have different attributes but that work in a complementary manners offers distinct advantages. However, complicated sensors interactions may occur. Hemodynamic sensors detect changes in the hemodynamic performances of the heart, which partially depends on the autonomic nervous system-induced inotropic regulation of myocardial fibers. Specific hemodynamic sensors have been designed to measure different expression of the cardiac contraction strength: Peak Endocardial Acceleration (PEA, Closed Loop Stimulation (CLS and TransValvular Impedance (TVI, guided by intraventricular impedance variations. Rate-responsive pacing is just one of the potential applications of hemodynamic sensors in implantable pacemakers. Other issues discussed in the paper include: hemodynamic monitoring for the optimal programmation and follow up of patients with cardiac resynchronization therapy; hemodynamic deterioration impact of tachyarrhythmias; hemodynamic upper rate limit control; monitoring and prevention of vasovagal malignant syncopes.

  11. Cell and gene therapy for arrhythmias: Repair of cardiac conduction damage

    Institute of Scientific and Technical Information of China (English)

    Yong-Fu Xiao

    2011-01-01

    Action potentials generated in the sinoatrial node(SAN)dominate the rhythm and rate of a healthy human heart.Subsequently,these action potentials propagate to the whole heart via its conduction system .Abnormalities of impulse generation and/or propagation in a heart can cause arrhythmias.For example,SAN dysfunction or conduction block of the atrioventricular node can lead to serious bradycardia which is currently treated with an implanted electronic pacemaker.On the other hand conduction damage may cause reentrant tachyarrhythmias which are primarily treated pharmacologically or by medical device-based therapies,including defibrillation and tissue ablation.However,drug therapies sometimes may not be effective or are associated with serious side effects.Device-based therapies for cardiac arrhythmias,even with well developed technology,still face inadequacies,limitations,hardware complications,and other challenges.Therefore,scientists are actively seeking other alternatives for antiarrhythmic therapy.In particular,cells and genes used for repairing cardiac conduction damage/defect have been investigated in various studies both in vitro and in vivo.Despite the complexities of the excitation and conduction systems of the heart,cell and gene-based strategies provide novel alternatives for treatment or cure of cardiac anhythmias.This review summarizes some highlights of recent research progress in this field.

  12. The effect of endotoxin on the controllability of cardiac rhythm in rats.

    Science.gov (United States)

    Mazloom, Roham; Shirazi, Amir H; Hajizadeh, Sohrab; Dehpour, Ahmad R; Mani, Ali R

    2014-03-01

    Decreased heart rate variability (HRV) has both diagnostic and prognostic value in patients with sepsis. However, it is not known whether reduced HRV in sepsis reflects an altered input from the autonomic nervous system or a remodeling of the cardiac pacemaker cells by inflammatory mediators. The present study aimed to investigate the effect of endotoxin on the heart rate dynamics of a denervated isolated heart in rats. Saline or endotoxin was injected into rats and their hearts were isolated and perfused. Atrial electrical activity was recorded and memory length in the time-series was assessed using inverse statistical analysis. Memory was defined as a statistical feature that lasts for a period of time and distinguishes the time-series from a random process. Endotoxaemic hearts exhibited a prolonged memory compared to the controls with respect to observing rare events. This indicates that a sudden decelerating event could potentially affect the cardiac rhythm of an endotoxaemic heart for a longer time than the controls. The prolongation of memory is indirectly linked to a reduced controllability in a complex system; therefore our data may provide evidence for a reduced controllability in cardiac rhythm following endotoxaemia.

  13. Battery Cell Balancing System and Method

    Science.gov (United States)

    Davies, Francis J. (Inventor)

    2014-01-01

    A battery cell balancing system is operable to utilize a relatively small number of transformers interconnected with a battery having a plurality of battery cells to selectively charge the battery cells. Windings of the transformers are simultaneously driven with a plurality of waveforms whereupon selected battery cells or groups of cells are selected and charged. A transformer drive circuit is operable to selectively vary the waveforms to thereby vary a weighted voltage associated with each of the battery cells.

  14. Advanced Battery Diagnosis for Electric Vehicles

    OpenAIRE

    Lamichhane, Chudamani

    2008-01-01

    Summary Literatures on battery technologies and diagnosis of its parameters were studied. The innovative battery technologies from basic knowledge to world standard testing procedures were analysed and discussed in the report. The established battery test station and flowchart was followed during the battery test preparation and testing. In order to understand and verify the battery performance, the well established test procedures developed by USABC (United States Advanced Battery Consorti...

  15. Cardiac potassium channel subtypes

    DEFF Research Database (Denmark)

    Schmitt, Nicole; Grunnet, Morten; Olesen, Søren-Peter

    2014-01-01

    About 10 distinct potassium channels in the heart are involved in shaping the action potential. Some of the K(+) channels are primarily responsible for early repolarization, whereas others drive late repolarization and still others are open throughout the cardiac cycle. Three main K(+) channels...

  16. Cardiac Risk Assessment

    Science.gov (United States)

    ... Risk Assessment Related tests: Lipid Profile , VLDL Cholesterol , hs-CRP , Lp(a) Overview | Common Questions | Related Pages What ... cardiac risk include: High-sensitivity C-reactive protein (hs-CRP) : Studies have shown that measuring CRP with a ...

  17. The cardiac malpositions.

    Science.gov (United States)

    Perloff, Joseph K

    2011-11-01

    Dextrocardia was known in the 17th century and was 1 of the first congenital malformations of the heart to be recognized. Fifty years elapsed before Matthew Baillie published his account of complete transposition in a human of the thoracic and abdominal viscera to the opposite side from what is natural. In 1858, Thomas Peacock stated that "the heart may be congenitally misplaced in various ways, occupying either an unusual position within the thorax, or being situated external to that cavity." In 1915, Maude Abbott described ectopia cordis, and Richard Paltauf's remarkable illustrations distinguished the various types of dextrocardia. In 1928, the first useful classification of the cardiac malpositions was proposed, and in 1966, Elliott et al's radiologic classification set the stage for clinical recognition. The first section of this review deals with the 3 basic cardiac malpositions in the presence of bilateral asymmetry. The second section deals with cardiac malpositions in the presence of bilateral left-sidedness or right-sidedness. Previous publications on cardiac malpositions are replete with an arcane vocabulary that confounds rather than clarifies. Even if the terms themselves are understood, inherent complexity weighs against clarity. This review was designed as a guided tour of an unfamiliar subject.

  18. Hepato-cardiac disorders

    Institute of Scientific and Technical Information of China (English)

    Yasser; Mahrous; Fouad; Reem; Yehia

    2014-01-01

    Understanding the mutual relationship between the liver and the heart is important for both hepatologists and cardiologists. Hepato-cardiac diseases can be classified into heart diseases affecting the liver, liver diseases affecting the heart, and conditions affecting the heart and the liver at the same time. Differential diagnoses of liver injury are extremely important in a cardiologist’s clinical practice calling for collaboration between cardiologists and hepatologists due to the many other diseases that can affect the liver and mimic haemodynamic injury. Acute and chronic heart failure may lead to acute ischemic hepatitis or chronic congestive hepatopathy. Treatment in these cases should be directed to the primary heart disease. In patients with advanced liver disease, cirrhotic cardiomyopathy may develop including hemodynamic changes, diastolic and systolic dysfunctions, reduced cardiac performance and electrophysiological abnormalities. Cardiac evaluation is important for patients with liver diseases especially before and after liver transplantation. Liver transplantation may lead to the improvement of all cardiac changes and the reversal of cirrhotic cardiomyopathy. There are systemic diseases that may affect both the liver and the heart concomitantly including congenital, metabolic and inflammatory diseases as well as alcoholism. This review highlights these hepatocardiac diseases

  19. Study of electrochemical properties of thin film materials obtained using plasma technologies for production of electrodes for pacemakers

    Science.gov (United States)

    Obrezkov, O. I.; Vinogradov, V. P.; Krauz, V. I.; Mozgrin, D. V.; Guseva, I. A.; Andreev, E. S.; Zverev, A. A.; Starostin, A. L.

    2016-09-01

    Studies of thin film materials (TFM) as coatings of tips of pacemaker electrodes implanted into the human heart have been performed. TFM coatings were deposited in vacuum by arc magnetron discharge plasma, by pulsed discharge of “Plasma Focus”, and by electron beam evaporation. Simulation of electric charge transfer to the heart in physiological blood- imitator solution and determination of electrochemical properties of the coatings were carried out. TFM of highly developed surface of contact with tissue was produced by argon plasma spraying of titanium powder with subsequent coating by titanium nitride in vacuum arc assisted by Ti ion implantation. The TFM coatings of pacemaker electrode have passed necessary clinical tests and were used in medical practice. They provide low voltage myocardium stimulation thresholds within the required operating time.

  20. Ivabradine and metoprolol differentially affect cardiac glucose metabolism despite similar heart rate reduction in a mouse model of dyslipidemia.

    Science.gov (United States)

    Vaillant, Fanny; Lauzier, Benjamin; Ruiz, Matthieu; Shi, Yanfen; Lachance, Dominic; Rivard, Marie-Eve; Bolduc, Virginie; Thorin, Eric; Tardif, Jean-Claude; Des Rosiers, Christine

    2016-10-01

    While heart rate reduction (HRR) is a target for the management of patients with heart disease, contradictory results were reported using ivabradine, which selectively inhibits the pacemaker If current, vs. β-blockers like metoprolol. This study aimed at testing whether similar HRR with ivabradine vs. metoprolol differentially modulates cardiac energy substrate metabolism, a factor determinant for cardiac function, in a mouse model of dyslipidemia (hApoB(+/+);LDLR(-/-)). Following a longitudinal study design, we used 3- and 6-mo-old mice, untreated or treated for 3 mo with ivabradine or metoprolol. Cardiac function was evaluated in vivo and ex vivo in working hearts perfused with (13)C-labeled substrates to assess substrate fluxes through energy metabolic pathways. Compared with 3-mo-old, 6-mo-old dyslipidemic mice had similar cardiac hemodynamics in vivo but impaired (P ivabradine-treated hearts displayed significantly higher stroke volume values and glycolysis vs. their metoprolol-treated counterparts ex vivo, values for the ivabradine group being often not significantly different from 3-mo-old mice. Further analyses highlighted additional significant cardiac alterations with disease progression, namely in the total tissue level of proteins modified by O-linked N-acetylglucosamine (O-GlcNAc), whose formation is governed by glucose metabolism via the hexosamine biosynthetic pathway, which showed a similar pattern with ivabradine vs. metoprolol treatment. Collectively, our results emphasize the implication of alterations in cardiac glucose metabolism and signaling linked to disease progression in our mouse model. Despite similar HRR, ivabradine, but not metoprolol, preserved cardiac function and glucose metabolism during disease progression.